Shavit, Itai; Brant, Rollin; Nijssen-Jordan, Cheri; Galbraith, Roger; Johnson, David W
2006-12-01
Assessment of dehydration in young children currently depends on clinical judgment, which is relatively inaccurate. By using digital videography, we developed a way to assess capillary-refill time more objectively. Our goal was to determine whether digitally measured capillary-refill time assesses the presence of significant dehydration (> or = 5%) in young children with gastroenteritis more accurately than conventional capillary refill and overall clinical assessment. We prospectively enrolled children with gastroenteritis, 1 month to 5 years of age, who were evaluated in a tertiary-care pediatric emergency department and judged by a triage nurse to be at least mildly dehydrated. Before any treatment, we measured the weight and digitally measured capillary-refill time of these children. Pediatric emergency physicians determined capillary-refill time by using conventional methods and degree of dehydration by overall clinical assessment by using a 7-point Likert scale. Postillness weight gain was used to estimate fluid deficit; beginning 48 hours after assessment, children were reweighed every 24 hours until 2 sequential weights differed by no more than 2%. We compared the accuracy of digitally measured capillary-refill time with conventional capillary refill and overall clinical assessment by determining sensitivities, specificities, likelihood ratios, and area under the receiver operator characteristic curves. A total of 83 patients were enrolled and had complete follow-up; 13 of these patients had significant dehydration (> or = 5% of body weight). The area under the receiver operator characteristic curves for digitally measured capillary-refill time and overall clinical assessment relative to fluid deficit (< 5% vs > or = 5%) were 0.99 and 0.88, respectively. Positive likelihood ratios were 11.7 for digitally measured capillary-refill time, 4.5 for conventional capillary refill, and 4.1 for overall clinical assessment. Results of this prospective cohort study suggest that digitally measured capillary-refill time more accurately predicts significant dehydration (> or = 5%) in young children with gastroenteritis than overall clinical assessment.
Fleming, Susannah; Gill, Peter; Jones, Caroline; Taylor, James A.; Van den Bruel, Ann; Heneghan, Carl; Roberts, Nia; Thompson, Matthew
2015-01-01
Importance Capillary refill time (CRT) is widely recommended as part of the routine assessment of unwell children. Objective To determine the diagnostic value of capillary refill time for a range of serious outcomes in children. Methods We searched Medline, Embase and CINAHL from inception to June 2014. We included studies that measured both capillary refill time and a relevant clinical outcome such as mortality, dehydration, meningitis, or other serious illnesses in children aged up to 18 years of age. We screened 1,265 references, of which 24 papers were included in this review. Where sufficient studies were available, we conducted meta-analysis and constructed hierarchical summary ROC curves. Results Meta-analysis on the relationship between capillary refill time and mortality resulted in sensitivity of 34.6% (95% CI 23.9 to 47.1%), specificity 92.3% (88.6 to 94.8%), positive likelihood ratio 4.49 (3.06 to 6.57), and negative likelihood ratio 0.71 (0.60 to 0.84). Studies of children attending Emergency Departments with vomiting and diarrhea showed that capillary refill time had specificity of 89 to 94% for identifying 5% dehydration, but sensitivity ranged from 0 to 94%. This level of heterogeneity precluded formal meta-analysis of this outcome. Meta-analysis was not possible for other outcomes due to insufficient data, but we found consistently high specificity for a range of outcomes including meningitis, sepsis, admission to hospital, hypoxia, severity of illness and dengue. Conclusions Our results show that capillary refill time is a specific sign, indicating that it can be used as a “red-flag”: children with prolonged capillary refill time have a four-fold risk of dying compared to children with normal capillary refill time. The low sensitivity means that a normal capillary refill time should not reassure clinicians. PMID:26375953
Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb.
Henricson, Joakim; Toll John, Rani; Anderson, Chris D; Björk Wilhelms, Daniel
2017-12-02
The capillary refill test was introduced in 1947 to help estimate circulatory status in critically ill patients. Guidelines commonly state that refill should occur within 2 s after releasing 5 s of firm pressure (e.g., by the physician's finger) in the normal healthy supine patient. A slower refill time indicates poor skin perfusion, which can be caused by conditions including sepsis, blood loss, hypoperfusion, and hypothermia. Since its introduction, the clinical usefulness of the test has been debated. Advocates point out its feasibility and simplicity and claim that it can indicate changes in vascular status earlier than changes in vital signs such as heart rate. Critics, on the other hand, stress that the lack of standardization in how the test is performed and the highly subjective nature of the naked eye assessment, as well as the test's susceptibility to ambient factors, markedly lowers the clinical value. The aim of the present work is to describe in detail the course of the refill event and to suggest potentially more objective and exact endpoint values for the capillary refill test using diffuse polarization spectroscopy.
Impact of patient and environmental factors on capillary refill time in adults.
Anderson, Bronwyn; Kelly, Anne-Maree; Kerr, Debra; Clooney, Megan; Jolley, Damien
2008-01-01
Capillary refill time (CRT) has been taught as a rapid indicator of circulatory status. The aim of this study was to define normal CRT in the Australian context and the environmental, patient, and drug factors that influence it. This prospective observational study included healthy adults at hospital clinics, workplaces, universities, and community groups. Volunteer participants provided their age, sex, ethnic group, and use of hypertensive or cardiac medications. Capillary refill time, ambient temperature, and patient temperature were recorded in a standard manner. Data were analyzed using descriptive statistics and regression analyses. The 95th percentile was used to define the upper limit of normal. One thousand participants were included; 57% were women, 90% were white, and 21% were taking cardiac medications. The median CRT was 1.9 seconds (95th percentile, 3.5 seconds). The CRT increased 3.3% for each additional decade of age. The CRT was also on average 7% lower in men than in women. The CRT decreased by 1.2% per degree-Celsius rise of ambient temperature, independently of patient's temperature, and decreased by 5% for each degree-Celsius rise in patient temperature, independently of ambient temperature. On multivariant analysis, age, sex, ambient temperature, and patient temperature were statistically significant predictors of CRT, but together explain only 8% of the observed variability. Capillary refill time varies with environmental and patient factors, but these account for only a small proportion of the variability observed. Its suitability as a reliable clinical test is doubtful.
Capillary device refilling. [liquid rocket propellant tank tests
NASA Technical Reports Server (NTRS)
Blatt, M. H.; Merino, F.; Symons, E. P.
1980-01-01
An analytical and experimental study was conducted dealing with refilling start baskets (capillary devices) with settled fluid. A computer program was written to include dynamic pressure, screen wicking, multiple-screen barriers, standpipe screens, variable vehicle mass for computing vehicle acceleration, and calculation of tank outflow rate and vapor pullthrough height. An experimental apparatus was fabricated and tested to provide data for correlation with the analytical model; the test program was conducted in normal gravity using a scale-model capillary device and ethanol as the test fluid. The test data correlated with the analytical model; the model is a versatile and apparently accurate tool for predicting start basket refilling under actual mission conditions.
NASA Technical Reports Server (NTRS)
Blatt, M. H.; Bradshaw, R. D.; Risberg, J. A.
1980-01-01
Technology areas critical to the development of cryogenic capillary devices were studied. Passive cooling of capillary devices was investigated with an analytical and experimental study of wicking flow. Capillary device refilling with settled fluid was studied using an analytical and experimental program that resulted in successful correlation of a versatile computer program with test data. The program was used to predict Centaur D-1S LO2 and LH2 start basket refilling. Comparisons were made between the baseline Centaur D-1S propellant feed system and feed system alternatives including systems using capillary devices. The preferred concepts from the Centaur D-1S study were examined for APOTV and POTV vehicles for delivery and round trip transfer of payloads between LEO and GEO. Mission profiles were determined to provide propellant usage timelines and the payload partials were defined.
In vivo dynamic analysis of water refilling in embolized xylem vessels of intact Zea mays leaves
Ryu, Jeongeun; Hwang, Bae Geun; Lee, Sang Joon
2016-01-01
Background and Aims The refilling of embolized xylem vessels under tension is a major issue in water transport among vascular plants. However, xylem embolism and refilling remain poorly understood because of technical limitations. Direct observation of embolism repair in intact plants is essential to understand the biophysical aspects of water refilling in embolized xylem vessels. This paper reports on details of the water refilling process in leaves of the intact herbaceous monocot plant Zea mays and its refilling kinetics obtained by a direct visualization technique. Methods A synchrotron X-ray micro-imaging technique was used to monitor water refilling in embolized xylem vessels of intact maize leaves. Xylem embolism was artificially induced by using a glass capillary; real-time images of water refilling dynamics were consecutively captured at a frame rate of 50 f.p.s. Key Results Water supply in the radial direction initiates droplet formation on the wall of embolized xylem vessels. Each droplet grows into a water column; this phenomenon shows translation motion or continuous increase in water column volume. In some instances, water columns merge and form one large water column. Water refilling in the radial direction causes rapid recovery from embolism in several minutes. The average water refilling velocity is approx. 1 μm s−1. Conclusions Non-destructive visualization of embolized xylem vessels demonstrates rapid water refilling and gas bubble removal as key elements of embolism repair in a herbaceous monocot species. The refilling kinetics provides new insights into the dynamic mechanism of water refilling phenomena. PMID:27539601
Capillary refill: prognostic value in Kenyan children
Pamba, A; Maitland, K
2004-01-01
Aims: To determine whether delayed capillary refill time (>3 seconds) is a useful prognostic indicator in Kenyan children admitted to hospital. Methods: A total of 4160 children admitted to Kilifi District Hospital with malaria, malarial anaemia, acute respiratory tract infection (ARI), severe anaemia (haemoglobin <50 g/l), gastroenteritis, malnutrition, meningitis, or septicaemia were studied. Results: Overall, delayed capillary refill time (dCRT), present in 346/4160 (8%) of the children, was significantly more common in fatal cases (44/189, 23%) than survivors (7.5%), and had useful prognostic value. In children admitted with malaria, gastroenteritis, or malnutrition, likelihood ratio tests suggested that dCRT was useful in identifying high risk groups for mortality, but its prognostic value in anaemia, ARI, and sepsis was unclear due to low case fatality or limited numbers. The severity features of impaired consciousness and deep breathing were significantly associated both with the presence of dCRT and fatal outcome. In children, with either of these severity features, a less stringent value of dCRT(>2 s) identified 50% of children with hypotension (systolic BP <2SD) and 40% of those requiring volume resuscitation (for metabolic acidosis). Conclusions: Although CRT is a simple bedside test, which may be used in resource poor settings as a guide to the circulatory status, dCRT should not be relied on in the absence of other features of severity. In non-severe disease, the additional presence of hypoxia, a moderately raised creatinine (>80 µmol/l), or a raised white cell count should prompt the need for fluid expansion. PMID:15383440
An automated quasi-continuous capillary refill timing device
Blaxter, L L; Morris, D E; Crowe, J A; Henry, C; Hill, S; Sharkey, D; Vyas, H; Hayes-Gill, B R
2016-01-01
Capillary refill time (CRT) is a simple means of cardiovascular assessment which is widely used in clinical care. Currently, CRT is measured through manual assessment of the time taken for skin tone to return to normal colour following blanching of the skin surface. There is evidence to suggest that manually assessed CRT is subject to bias from ambient light conditions, a lack of standardisation of both blanching time and manually applied pressure, subjectiveness of return to normal colour, and variability in the manual assessment of time. We present a novel automated system for CRT measurement, incorporating three components: a non-invasive adhesive sensor incorporating a pneumatic actuator, a diffuse multi-wavelength reflectance measurement device, and a temperature sensor; a battery operated datalogger unit containing a self contained pneumatic supply; and PC based data analysis software for the extraction of refill time, patient skin surface temperature, and sensor signal quality. Through standardisation of the test, it is hoped that some of the shortcomings of manual CRT can be overcome. In addition, an automated system will facilitate easier integration of CRT into electronic record keeping and clinical monitoring or scoring systems, as well as reducing demands on clinicians. Summary analysis of volunteer (n = 30) automated CRT datasets are presented, from 15 healthy adults and 15 healthy children (aged from 5 to 15 years), as their arms were cooled from ambient temperature to 5°C. A more detailed analysis of two typical datasets is also presented, demonstrating that the response of automated CRT to cooling matches that of previously published studies. PMID:26642080
Challenges in automated estimation of capillary refill time in dogs
NASA Astrophysics Data System (ADS)
Cugmas, Blaž; Spigulis, Janis
2018-02-01
Capillary refill time (CRT) is a part of the cardiorespiratory examination in dogs. Changes in CRT can reflect pathological conditions like shock or anemia. Visual CRT estimation has low repeatability; therefore, optical systems for automated estimation have recently appeared. Since existing systems are unsuitable for use in dogs, we designed a simple, small and portable device, which could be easily used at veterinary clinic. The device was preliminarily tested on several measurement sites in two dogs. Not all measurement sites were suitable for CRT measurements due to underlying tissue optical and mechanical properties. The CRT measurements were possible on the labial mucosa, above the sternum and on the digit where CRT was in the range of values, retrieved from the color video of the visual CRT measurement. It seems that light penetration predominantly governs tissue optical response when the pressure is applied. Therefore, it is important to select a proper light, which reaches only superficial capillaries and does not penetrate deeper. Blue or green light is probably suitable for light skin or mucosa, on the other hand, red or near-infrared might be used for skin with pigmented or thick epidermis. Additionally, further improvements of the device design are considered, like adding a calibrated spring, which would insure application of consistent pressure.
Study of liquid and vapor flow into a Centaur capillary device
NASA Technical Reports Server (NTRS)
Blatt, M. H.; Risberg, J. A.
1979-01-01
The following areas of liquid and vapor flow were analyzed and experimentally evaluated; 1) the refilling of capillary devices with settled liquid, and 2) vapor flow across wetted screens. These investigations resulted in: 1) the development of a versatile computer program that was successfully correlated with test data and used to predict Centaur D-1S LO2 and LH2 start basket refilling; 2) the development of a semi-empirical model that was only partially correlated with data due to difficulties in obtaining repeatable test results. Also, a comparison was made to determine the best propellant management system for the Centaur D-1S vehicle. The comparison identified the basline Centaur D-1S system (using pressurization, boost pumps and propellant settling) as the best candidate based on payload weight penalty. However, other comparison criteria and advanced mission condition were identified where pressure fed systems, thermally subcooled boost pumps and capillary devices would be selected as attractive alternatives.
How to Predict Oral Rehydration Failure in Children With Gastroenteritis.
Geurts, Dorien; Steyerberg, Ewout W; Moll, Henriëtte; Oostenbrink, Rianne
2017-11-01
Oral rehydration is the standard in most current guidelines for young children with acute gastroenteritis (AGE). Failure of oral rehydration can complicate the disease course, leading to morbidity due to severe dehydration. We aimed to identify prognostic factors of oral rehydration failure in children with AGE. A prospective, observational study was performed at the Emergency department, Erasmus Medical Centre, Rotterdam, The Netherlands, 2010-2012, including 802 previously healthy children, ages 1 month to 5 years with AGE. Failure of oral rehydration was defined by secondary rehydration by a nasogastric tube, or hospitalization or revisit for dehydration within 72 hours after initial emergency department visit. We observed 167 (21%) failures of oral rehydration in a population of 802 children with AGE (median 1.03 years old, interquartile range 0.4-2.1; 60% boys). In multivariate logistic regression analysis, independent predictors for failure of oral rehydration were a higher Manchester Triage System urgency level, abnormal capillary refill time, and a higher clinical dehydration scale score. Early recognition of young children with AGE at risk of failure of oral rehydration therapy is important, as emphasized by the 21% therapy failure in our population. Associated with oral rehydration failure are higher Manchester Triage System urgency level, abnormal capillary refill time, and a higher clinical dehydration scale score.
Capillary refill time is an unreliable indicator of cardiovascular status in term neonates.
LeFlore, Judy L; Engle, William D
2005-06-01
Decisions regarding the need for volume replacement in neonates often are made in the immediate newborn period. Capillary refill time (CRT) is used as an indicator of circulatory status; however, recent data show that CRT varies considerably with age, ambient and skin temperature, anatomical site of measurement, and duration of pressure. The purpose of this study was to (1) examine the relationship between CRT and heart rate (HR) and blood pressure (BP) in term neonates, and (2) evaluate the differences among CRT values measured at 3 body sites and with varying duration of cutaneous pressure. This was a prospective, cross-sectional, correlational study. Subjects Forty-two appropriate-weight-for-gestational-age (AGA) neonates with birthweights, (M = 3407; SD = +/- 540 g), gestational ages (M = 39 weeks; SD = +/- 1 week), and sex (21 males, 21 females). Infants had no history of perinatal distress or maternal chorioamnionitis. Each neonate was studied prospectively 1 to 4 hours after birth. The infants were clothed with only a diaper and evaluated on a radiant warmer bed set to achieve an axillary temperature of 36.5 degrees to 37.0 degrees C. Capillary refill time was measured with a digital stopwatch at 3 sites: volar surface of finger (F), plantar surface of heel (H), and lower sternum (St), using brief (1- to 2-second) and extended (3- to 4-second) pressure. Heart rate was auscultated and counted for 60 seconds, and BP was measured by oscillometry. Relationships among variables were assessed by Pearson correlation coefficient, analysis of variance, and multiple regression analysis. The Bonferroni correction for multiple comparisons was applied. Capillary refill time, blood pressure, and heart rate. There was no significant site variation for CRT for either brief (2.4 +/- 0.6 to 2.9 +/- 1.0 seconds) or extended (3.8 +/- 0.8 to 4.3 +/- 0.8 seconds) pressure. However, regardless of site, CRT was greater when extended versus brief pressure was used (P < 0.001). There were no significant correlations between HR and CRT. There was a moderate, direct relationship between BP and CRT observed in the following anatomic sites: (1) sternum/extended pressure and systolic BP (SBP), diastolic BP, and mean BP (r = 0.35, P = 0.02; r = 0.49, P = 0.001; and r = 0.43, P = 0.005, respectively); (2) sternum/brief pressure and SBP (r = 0.31, P = 0.05); and (3) finger/extended pressure and SBP (r = 0.30, P = 0.05). An unanticipated moderate, direct correlation between BP and CRT was observed; prolongation of CRT occurred with elevated blood pressure. This finding may have been secondary to increased circulating vasoactive substances in the newborn period; measurement of these substances was beyond the scope of this study. In addition, CRT was highly dependent on the duration of cutaneous pressure, regardless of the site. These 2 findings indicate that CRT may be an unreliable indicator of cardiovascular status in the term neonate during the first 4 hours after birth.
CE: Assessing Patients During Septic Shock Resuscitation.
Bridges, Elizabeth
2017-10-01
: In 2015, the Surviving Sepsis Campaign six-hour bundle was updated. The revised version now recommends documenting the reassessment of volume status and tissue perfusion after initial fluid resuscitation through a repeated focused examination. This article addresses the practice and interpretation of two components of this examination in adults: capillary refill time and skin mottling score. It further discusses how to best integrate these noninvasive parameters into the care of patients undergoing resuscitation for septic shock.
Centaur propellant acquisition system study
NASA Technical Reports Server (NTRS)
Blatt, M. H.; Walter, M. D.
1975-01-01
A study was performed to determine the desirability of replacing the hydrogen peroxide settling system on the Centaur D-1S with a capillary acquisition system. A comprehensive screening was performed to select the most promising capillary device fluid acquisition, thermal conditioning, and fabrication techniques. Refillable start baskets and bypass feed start tanks were selected for detailed design. Critical analysis areas were settling and refilling, start sequence development with an initially dry boost pump, and cooling the fluid delivered to the boost pump in order to provide necessary net position suction head (NPSH). Design drawings were prepared for the start basket and start tank concepts for both LO2 and LH2 tanks. System comparisons indicated that the start baskets using wicking for thermal conditioning, and thermal subcooling for boost pump NPSH, are the most desirable systems for future development.
Centaur propellant acquisition system
NASA Technical Reports Server (NTRS)
Blatt, M. H.; Aydelott, J. C.
1975-01-01
The desirability of replacing the hydrogen peroxide settling system of the Centaur D-1S with a capillary acquisition system was evaluated. A comprehensive screening was performed to select the most promising capillary device fluid acquisition, thermal conditioning, and fabrication techniques. Refillable start baskets and bypass feed start tanks were selected for detailed design. Critical analysis areas were settling and refilling, start sequence development with an initially dry boost pump, and cooling the fluid delivered to the boost pump to provide the necessary net positive suction head (NPSH). Design drawings were prepared for start basket and start tank concepts for both the liquid oxygen and liquid hydrogen tanks. System comparisons indicated that the start baskets using wicking flow for thermal conditioning, and thermal subcooling for providing boost pump NPSH, are the most desirable systems for future Centaur acquisition system development.
Capillary refill time: a study of interobserver reliability among nurses and nurse assistants.
Brabrand, Mikkel; Hosbond, Susanne; Folkestad, Lars
2011-02-01
The interobserver variability of capillary refill time (CRT) has been questioned. Earlier studies of interobserver variability of CRT have been on a large number of patients but with few observers. The objective of our study was to investigate how a large group of nurses and nurse assistants would grade CRT. We recorded a video of the index finger of six medical patients and these were shown to nurses and nurse assistants. They were asked to record the CRT and whether they found this value to be normal. The data were analyzed using the Fleiss Kappa Coefficient Analysis and graded according to the Landis and Koch correlation. Correlation between the exact numbers was evaluated using interclass correlation. Nine nurse assistants and 37 nurses participated. The patients were aged between 44 and 87 years. All but one patient had a systolic blood pressure reading above 130 mmHg. All had arterial blood oxygen saturation above 92% and all but one had normal body temperature. The κ value for normality was 0.56. The interclass correlation of measurement of CRT was 0.62. This is the largest interobserver study of CRT when looking at the number of observers. We found an only moderate agreement for the exact value of CRT and a moderate agreement for normality. We believe that CRT should be used with caution in clinical practice.
Goodall, R; Claireaux, H; Hill, J; Wilson, E; Monsell, F; Boast Collaborative; Tarassoli, P
2018-03-01
Aims Supracondylar fractures are the most frequently occurring paediatric fractures about the elbow and may be associated with a neurovascular injury. The British Orthopaedic Association Standards for Trauma 11 (BOAST 11) guidelines describe best practice for supracondylar fracture management. This study aimed to assess whether emergency departments in the United Kingdom adhere to BOAST 11 standard 1: a documented assessment, performed on presentation, must include the status of the radial pulse, digital capillary refill time, and the individual function of the radial, median (including the anterior interosseous), and ulnar nerves. Materials and Methods Stage 1: We conducted a multicentre, retrospective audit of adherence to BOAST 11 standard 1. Data were collected from eight hospitals in the United Kingdom. A total of 433 children with Gartland type 2 or 3 supracondylar fractures were eligible for inclusion. A centrally created data collection sheet was used to guide objective analysis of whether BOAST 11 standard 1 was adhered to. Stage 2: We created a quality improvement proforma for use in emergency departments. This was piloted in one of the hospitals used in the primary audit and was re-audited using equivalent methodology. In all, 102 patients presenting between January 2016 and July 2017 were eligible for inclusion in the re-audit. Results Stage 1: Of 433 patient notes audited, adherence to BOAST 11 standard 1 was between 201 (46%) and 232 (54%) for the motor and sensory function of the individual nerves specified, 318 (73%) for radial pulse, and 247 (57%) for digital capillary refill time. Stage 2: Of 102 patient notes audited, adherence to BOAST 11 standard 1 improved to between 72 (71%) and 80 (78%) for motor and sensory function of the nerves, to 84 (82%) for radial pulse, and to 82 (80%) for digital capillary refill time. Of the 102 case notes reviewed in stage 2, only 44 (43%) used the quality improvement proforma; when the proforma was used, adherence improved to between 40 (91%) and 43 (98%) throughout. Conclusion Adherence to BOAST 11 standard 1 is poor in hospitals across the country. This is concerning as neurovascular deficit may be an indication for emergent surgery, and missed neurovascular injury can cause long-term, or even permanent, functional impairment. We present a simple proforma that improves adherence to this standard, can easily be implemented into emergency departments, and may improve patient safety. Cite this article: Bone Joint J 2018;100-B:346-51.
Does point-of-care functional echocardiography enhance cardiovascular care in the NICU?
Sehgal, A; McNamara, P J
2008-11-01
Although the last two decades have seen major advances in the care of sick, extremely premature newborns, the approach to cardiovascular assessment and monitoring remains suboptimal owing to an overreliance on poorly predictive clinical markers such as heart rate or capillary refill time. Point-of-care functional echocardiography (PCFecho) enables real-time evaluation of cardiac performance and systemic hemodynamics to characterize acute physiology, identify the exact nature of cardiovascular compromise and guide therapeutic decisions. In this article, we will review four clinical scenarios where bedside functional cardiac imaging enabled delineation of the real clinical problem and refinement of the therapeutic care plan with direct patient benefits.
Law, Amy; Lee, Yi-Chien; Gorritz, Magdaliz; Plouffe, Leo
2014-08-01
This study evaluated contraceptive refill patterns of women insured commercially in the US who switched from oral contraceptives (OCs) to the patch or vaginal ring and assessed if switching contraceptive methods changes refill patterns. Women aged 15-44 with ≥2 patch or ring prescriptions and ≥2 OC prescriptions before the first patch/ring prescription were identified from the MarketScan® Commercial database (1/1/2002-6/30/2011). Refill patterns 1-year pre- and postindex date (first patch/ring prescription) were evaluated, and women were categorized as timely or delayed refillers on OCs and patch/ring. Regression modeling was used to investigate the association between refill patterns and contraceptive methods and switching effects on refill patterns. Of 17,814 women identified, 7901 switched to the patch, and 9913 switched to the ring. Among timely OC refillers, the percentage of timely refills decreased (patch: 95.6% to 79.4%, p<.001; ring: 96.5% to 74.3%, p<.001). However, among delayed OC refillers, the percentage of timely refills improved (patch: 47.9% to 72.2%, p<.001; ring: 50.4% to 64.0%, p<.001) during patch/ring use. Nonetheless, compared to timely OC refillers, women who were delayed OC refillers had 1.68-fold [95% confidence interval (CI): 1.52-1.84, p<.001] and 1.85-fold greater odds (CI: 1.69-2.02, p<.001) of being a delayed refiller while on the patch and ring, respectively. Switching to the patch or ring may improve refill behavior for women who have problems refilling OCs timely; however, the magnitude of the improvement may fail to improve ultimate contraceptive efficacy by simply switching to the patch or ring. The impact on timely refills of switching from OCs to either the patch or ring is complex and varies depending on the pattern of timely refills on OCs. Copyright © 2014 Elsevier Inc. All rights reserved.
The management of fever and petechiae: making sense of rash decisions.
Brogan, P A; Raffles, A
2000-12-01
In a retrospective and prospective audit of 55 children presenting to the paediatric assessment unit of a district general hospital with fever and petechial rash, 9% had significant bacterial sepsis. The "ILL criteria" (irritability, lethargy, low capillary refill) for the management of children with fever and petechiae are proposed.
The management of fever and petechiae: making sense of rash decisions
Brogan, P; Raffles, A
2000-01-01
In a retrospective and prospective audit of 55 children presenting to the paediatric assessment unit of a district general hospital with fever and petechial rash, 9% had significant bacterial sepsis. The "ILL criteria" (irritability, lethargy, low capillary refill) for the management of children with fever and petechiae are proposed. PMID:11087287
When and how do GPs record vital signs in children with acute infections? A cross-sectional study
Blacklock, Claire; Haj-Hassan, Tanya Ali; Thompson, Matthew J
2012-01-01
Background NICE recommendations and evidence from ambulatory settings promotes the use of vital signs in identifying serious infections in children. This appears to differ from usual clinical practice where GPs report measuring vital signs infrequently. Aim To identify frequency of vital sign documentation by GPs, in the assessment of children with acute infections in primary care. Design and setting Observational study in 15 general practice surgeries in Oxfordshire and Somerset, UK. Method A standardised proforma was used to extract consultation details including documentation of numerical vital signs, and words or phrases used by the GP in assessing vital signs, for 850 children aged 1 month to 16 years presenting with acute infection. Results Of the children presenting with acute infections 31.6% had one or more numerical vital signs recorded (269, 31.6%), however GP recording rate improved if free text proxies were also considered: at least one vital sign was then recorded in over half (54.1%) of children. In those with recorded numerical values for vital signs, the most frequent was temperature (210, 24.7%), followed by heart rate (62, 7.3%), respiratory rate (58, 6.8%), and capillary refill time (36, 4.2%). Words or phrases for vital signs were documented infrequently (temperature 17.6%, respiratory rate 14.6%, capillary refill time 12.5%, and heart rate 0.5%), Text relating to global assessment was documented in 313/850 (36.8%) of consultations. Conclusion GPs record vital signs using words and phrases as well as numerical methods, although overall documentation of vital signs is infrequent in children presenting with acute infections. PMID:23265227
Diagnosis and management of dehydration in children.
Canavan, Amy; Arant, Billy S
2009-10-01
The most useful individual signs for identifying dehydration in children are prolonged capillary refill time, abnormal skin turgor, and abnormal respiratory pattern. However, clinical dehydration scales based on a combination of physical examination findings are better predictors than individual signs. Oral rehydration therapy is the preferred treatment of mild to moderate dehydration caused by diarrhea in children. Appropriate oral rehydration therapy is as effective as intravenous fluid in managing fluid and electrolyte losses and has many advantages. Goals of oral rehydration therapy are restoration of circulating blood volume, restoration of interstitial fluid volume, and maintenance of rehydration. When rehydration is achieved, a normal age-appropriate diet should be initiated.
Alsma, Jelmer; van Saase, Jan L C M; Nanayakkara, Prabath W B; Schouten, W E M Ineke; Baten, Anique; Bauer, Martijn P; Holleman, Frits; Ligtenberg, Jack J M; Stassen, Patricia M; Kaasjager, Karin H A H; Haak, Harm R; Bosch, Frank H; Schuit, Stephanie C E
2017-05-01
Capillary refill time (CRT) is a clinical test used to evaluate the circulatory status of patients; various methods are available to assess CRT. Conventional clinical research often demands large numbers of patients, making it costly, labor-intensive, and time-consuming. We studied the interobserver agreement on CRT in a nationwide study by using a novel method of research called flash mob research (FMR). Physicians in the Netherlands were recruited by using word-of-mouth referrals, conventional media, and social media to participate in a nationwide, single-day, "nine-to-five," multicenter, cross-sectional, observational study to evaluate CRT. Patients aged ≥ 18 years presenting to the ED or who were hospitalized were eligible for inclusion. CRT was measured independently (by two investigators) at the patient's sternum and distal phalanx after application of pressure for 5 s (5s) and 15 s (15s). On October 29, 2014, a total of 458 investigators in 38 Dutch hospitals enrolled 1,734 patients. The mean CRT measured at the distal phalanx were 2.3 s (5s, SD 1.1) and 2.4 s (15s, SD 1.3). The mean CRT measured at the sternum was 2.6 s (5s, SD 1.1) and 2.7 s (15s, SD 1.1). Interobserver agreement was higher for the distal phalanx (κ value, 0.40) than for the sternum (κ value, 0.30). Interobserver agreement on CRT is, at best, moderate. CRT measured at the distal phalanx yielded higher interobserver agreement compared with sternal CRT measurements. FMR proved a valuable instrument to investigate a relatively simple clinical question in an inexpensive, quick, and reliable manner. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Scott, Halden F; Donoghue, Aaron J; Gaieski, David F; Marchese, Ronald F; Mistry, Rakesh D
2014-11-19
Early detection of compensated pediatric septic shock requires diagnostic tests that are sensitive and specific. Four physical exam signs are recommended for detecting pediatric septic shock prior to hypotension (cold extremities, mental status, capillary refill, peripheral pulse quality); this study tested their ability to detect patients who develop organ dysfunction among a cohort of undifferentiated pediatric systemic inflammatory response syndrome patients. A prospective cohort of 239 pediatric emergency department patients <19 years with fever and tachycardia and undergoing phlebotomy were enrolled. Physicians recorded initial physical exams on a standardized form. Abstraction of the medical record determined outcomes including organ dysfunction, intensive care unit stay, serious bacterial infection, and therapies. Organ dysfunction occurred in 13/239 (5.4%) patients. Presence of at least one sign was significantly associated with organ dysfunction (Relative Risk: 2.71, 95% CI: 1.05-6.99), and presence of at least two signs had a Relative Risk = 4.98 (95% CI: 1.82-13.58). The sensitivity of exam findings ranged from 8-54%, specificity from 84-98%. Signs were associated with increased risk of intensive care and fluid bolus, but not with serious bacterial infection, intravenous antibiotics or admission. Altered mental status and peripheral pulse quality were significantly associated with organ dysfunction, while abnormal capillary refill time and presence of cold, mottled extremities were not. Certain recommended physical exam signs were associated with increased risk of organ dysfunction, a rare outcome in this undifferentiated pediatric population with fever and tachycardia. Sensitivity was low, while specificity was high. Additional research into optimally sensitive and specific diagnostic strategies is needed.
Easy Come, Easy Go: Capillary Forces Enable Rapid Refilling of Embolized Primary Xylem Vessels.
Rolland, Vivien; Bergstrom, Dana M; Lenné, Thomas; Bryant, Gary; Chen, Hua; Wolfe, Joe; Holbrook, N Michele; Stanton, Daniel E; Ball, Marilyn C
2015-08-01
Protoxylem plays an important role in the hydraulic function of vascular systems of both herbaceous and woody plants, but relatively little is known about the processes underlying the maintenance of protoxylem function in long-lived tissues. In this study, embolism repair was investigated in relation to xylem structure in two cushion plant species, Azorella macquariensis and Colobanthus muscoides, in which vascular water transport depends on protoxylem. Their protoxylem vessels consisted of a primary wall with helical thickenings that effectively formed a pit channel, with the primary wall being the pit channel membrane. Stem protoxylem was organized such that the pit channel membranes connected vessels with paratracheal parenchyma or other protoxylem vessels and were not exposed directly to air spaces. Embolism was experimentally induced in excised vascular tissue and detached shoots by exposing them briefly to air. When water was resupplied, embolized vessels refilled within tens of seconds (excised tissue) to a few minutes (detached shoots) with water sourced from either adjacent parenchyma or water-filled vessels. Refilling occurred in two phases: (1) water refilled xylem pit channels, simplifying bubble shape to a rod with two menisci; and (2) the bubble contracted as the resorption front advanced, dissolving air along the way. Physical properties of the protoxylem vessels (namely pit channel membrane porosity, hydrophilic walls, vessel dimensions, and helical thickenings) promoted rapid refilling of embolized conduits independent of root pressure. These results have implications for the maintenance of vascular function in both herbaceous and woody species, because protoxylem plays a major role in the hydraulic systems of leaves, elongating stems, and roots. © 2015 American Society of Plant Biologists. All Rights Reserved.
In vivo Visualization of the Water-refilling Process in Xylem Vessels Using X-ray Micro-imaging
Lee, Sang-Joon; Kim, Yangmin
2008-01-01
Background and Aims Xylem vessels containing gases (embolized) must be refilled with water if they are to resume transport of water through the plant, so refilling is of great importance for the maintenance of water balance in plants. However, the refilling process is poorly understood because of inadequate examination methods. Simultaneous measurements of plant anatomy and vessel refilling are essential to elucidate the mechanisms involved. In the present work, a new technique based on phase-contrast X-ray imaging is presented that visualizes, in vivo and in real time, both xylem anatomy and refilling of embolized vessels. Methods With the synchrotron X-ray micro-imaging technique, the refilling of xylem vessels of leaves and a stem of Phyllostachys bambusoides with water is demonstrated under different conditions. The technique employs phase contrast imaging of X-ray beams, which are transformed into visible light and are photographed by a charge coupled device camera. X-ray images were captured consecutively at every 0·5 s with an exposure time of 10 ms. Key Results The interface (meniscus) between the water and gas phases in refilling the xylem vessels is displayed. During refilling, the rising menisci in embolized vessels showed repetitive flow, i.e. they temporarily stopped at the end walls of the vessel elements while gas bubbles were removed. The meniscus then passed through the end wall at a faster rate than the speed of flow in the main vessels. In the light, the speed of refilling in a specific vessel was slower than that in the dark, but this rate increased again after repeated periods in darkness. Conclusions Real-time, non-destructive X-ray micro-imaging is an important, useful and novel technique to study the relationship between xylem structure and the refilling of embolized vessels in intact plants. It provides new insight into understanding the mechanisms of water transport and the refilling of embolized vessels, which are not understood well. PMID:18077466
Investigation of VEGGIE Root Mat
NASA Technical Reports Server (NTRS)
Subbiah, Arun M.
2013-01-01
VEGGIE is a plant growth facility that utilizes the phenomenon of capillary action as its primary watering system. A cloth made of Meta Aramid fiber, known as Nomex is used to wick water up from a reservoir to the bottom of the plants roots. This root mat system is intended to be low maintenance with no moving parts and requires minimal crew interface time. Unfortunately, the water wicking rates are inconsistent throughout the plant life cycle, thus causing plants to die. Over-wicking of water occurs toward the beginning of the cycle, while under-wicking occurs toward the middle. This inconsistency of wicking has become a major issue, drastically inhibiting plant growth. The primary objective is to determine the root cause of the inconsistent wicking through experimental testing. Suspect causes for the capillary water column to break include: a vacuum effect due to a negative pressure gradient in the water reservoir, contamination of material due to minerals in water and back wash from plant fertilizer, induced air bubbles while using syringe refill method, and material limitations of Nomex's ability to absorb and retain water. Experimental testing will be conducted to systematically determine the cause of under and over-wicking. Pressure gages will be used to determine pressure drop during the course of the plant life cycle and during the water refill process. A debubbler device will be connected to a root mat in order to equalize pressure inside the reservoir. Moisture and evaporation tests will simultaneously be implemented to observe moisture content and wicking rates over the course of a plant cycle. Water retention tests will be performed using strips of Nomex to determine materials wicking rates, porosity, and absorptivity. Through these experimental tests, we will have a better understanding of material properties of Nomex, as well as determine the root cause of water column breakage. With consistent test results, a forward plan can be achieved to resolve the issue and give valuable insight for the next generation of VEGGIE.
Modelling Transcapillary Transport of Fluid and Proteins in Hemodialysis Patients
Pietribiasi, Mauro; Waniewski, Jacek; Załuska, Alicja; Załuska, Wojciech; Lindholm, Bengt
2016-01-01
Background The kinetics of protein transport to and from the vascular compartment play a major role in the determination of fluid balance and plasma refilling during hemodialysis (HD) sessions. In this study we propose a whole-body mathematical model describing water and protein shifts across the capillary membrane during HD and compare its output to clinical data while evaluating the impact of choosing specific values for selected parameters. Methods The model follows a two-compartment structure (vascular and interstitial space) and is based on balance equations of protein mass and water volume in each compartment. The capillary membrane was described according to the three-pore theory. Two transport parameters, the fractional contribution of large pores (αLP) and the total hydraulic conductivity (LpS) of the capillary membrane, were estimated from patient data. Changes in the intensity and direction of individual fluid and solute flows through each part of the transport system were analyzed in relation to the choice of different values of small pores radius and fractional conductivity, lymphatic sensitivity to hydraulic pressure, and steady-state interstitial-to-plasma protein concentration ratio. Results The estimated values of LpS and αLP were respectively 10.0 ± 8.4 mL/min/mmHg (mean ± standard deviation) and 0.062 ± 0.041. The model was able to predict with good accuracy the profiles of plasma volume and serum total protein concentration in most of the patients (average root-mean-square deviation < 2% of the measured value). Conclusions The applied model provides a mechanistic interpretation of fluid transport processes induced by ultrafiltration during HD, using a minimum of tuned parameters and assumptions. The simulated values of individual flows through each kind of pore and lymphatic absorption rate yielded by the model may suggest answers to unsolved questions on the relative impact of these not-measurable quantities on total vascular refilling and fluid balance. PMID:27483369
Schoenhaus, Robert; Lustig, Adam; Rivas, Silvia; Monrreal, Victor; Westrich, Kimberly D; Dubois, Robert W
2016-03-01
Even within fully integrated health care systems, primary care providers (PCPs) often lack support for medication management. Because challenges with conducting medication reconciliation, improving adherence, and achieving optimal patient outcomes continue to be prevalent nationally, it is critical that PCPs are provided the resources and support they need to provide high-quality, patient-centered care in an accountable care environment. Sharp Rees-Stealy Medical Group uses a fully electronic medication refill system that allows for a centralized team to manage all incoming requests. Over time, 16 disease-specific protocols were created that allowed the pharmacy team to absorb approximately 80% of incoming refill requests for all enrolled PCPs. The refill clinic assessed all clinic information that a PCP would normally review in order to approve a refill. Tasks performed by the clinical pharmacists included medication reconciliation, dosage adjustment, and coordination of distribution from external mail order and retail pharmacies. In 2014, the number of tasks related to refill management reviewed by the refill/medication therapy management service totaled 302,592, resulting in 140,350 refill authorizations and multiple interventions related to medication use. Physicians have estimated that the service provides between 20 and 30 minutes of time savings per day. Assuming an annual PCP salary of around $200,000, 20 to 30 minutes per day would amount to $33 to $50 saved per day per physician. The savings is even higher when time savings from other clinical staff is included. The development of this electronic medication refill service has provided the following important lessons: (a) organizations rely on a leader or champion to push through process reforms--this program started with reluctant physicians first to determine best practices; (b) the lack of clinical pharmacist profiles within electronic health records (EHR) is a serious concern, since the creation of these profiles may not be easy or timely; and (c) PCPs working within an EHR environment will quickly embrace the idea of a service that can save them up to 30 minutes per day. With PCPs continuing to take on additional population health management tasks in accountable care organizations, pharmacists can provide workload offsets by meaningfully contributing to medication-related care.
Pediatric myth: fever and petechiae.
Klinkhammer, Martin D; Colletti, James E
2008-09-01
A child presenting with petechiae and fever is assumed to have meningococcemia or another form of bacterial sepsis and therefore to require antibiotics, blood cultures, cerebrospinal fluid analysis and hospital admission. A review of the literature challenges this statement and suggests that a child presenting with purpura (or petechiae), an ill appearance and delayed capillary refill time or hypotension should be admitted and treated for meningococcal disease without delay. Conversely, a child with a petechial rash, which is confined to the distribution of the superior vena cava, is unlikely to have meningococcal disease. Outpatient therapy in this context is appropriate. In other children, a reasonable approach would be to draw blood for culture and C-reactive protein (CRP) while administering antibiotics. If the CRP is normal, these children could be discharged to follow-up in 1 day, whereas children with CRP values greater than 6 mg/L would be admitted.
Lester, Corey A; Chui, Michelle A
2016-01-01
To determine the effect of an automatic prescription refill program on the prescription pickup lag in community pharmacy. A post-only quasi-experimental design comparing automatic and manual refill prescription cohorts for each of the 3 Centers for Medicare and Medicaid medication adherence metrics. A 29-store community pharmacy chain in the Midwest. Community-dwelling patients over the age of 65 years receiving prescription medications included in the statin, renin-angiotensin-aldosterone system antagonist, or non-insulin diabetes adherence metrics. An automatic prescription refill program that initiated prescription refills on a standardized, recurrent basis, eliminating the need for patients to phone in or drop off prescription refills. The prescription pickup lag, defined as the number of days between a prescription being adjudicated in the pharmacy and the prescription being picked up by the patient. A total of 37,207 prescription fills were examined. There were 20.5%, 22.4%, and 23.3% of patients enrolled in the automatic prescription refill program for the statin, renin-angiotensin-aldosterone system antagonist, and diabetes adherence metrics, respectively. Prescriptions in the automatic prescription refill cohorts experienced a median pickup lag of 7 days compared with 1 day for the manual refill prescriptions. 35.2% of all manual refill prescriptions had a pickup lag of 0 days compared with 13% for automatic refills. However, 15.4% of automatic prescription refills had a pickup lag of greater than 14 days, compared with 4.8% of manual refills. Prescriptions in the automatic prescription refill programs were associated with a significantly longer amount of time in the pharmacy before being picked up by the patient. This increased pickup lag may contribute positively by smoothing out workload demands of pharmacy staff, but may contribute negatively owing to an increased amount of rework and greater inventory requirements. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Numerical simulation of filling a magnetic flux tube with a cold plasma: Anomalous plasma effects
NASA Technical Reports Server (NTRS)
Singh, Nagendra; Leung, W. C.
1995-01-01
Large-scale models of plasmaspheric refilling have revealed that during the early stage of the refilling counterstreaming ion beams are a common feature. However, the instability of such ion beams and its effect on refilling remain unexplored. In order to learn the basic effects of ion beam instabilities on refilling, we have performed numerical simulations of the refilling of an artificial magnetic flux tube. (The shape and size of the tube are assumed so that the essential features of the refilling problem are kept in the simulation and at the same time the small scale processes driven by the ion beams are sufficiently resolved.) We have also studied the effect of commonly found equatorially trapped warm and/or hot plasma on the filling of a flux tube with a cold plasma. Three types of simulation runs have been performed.
Ibrahim, Zuhaib; Tong, Dedi; Zhu, Shan; Mao, Qi; Pang, John; Andrew Lee, Wei Ping; Brandacher, Gerald; Kang, Jin U.
2013-01-01
Abstract. Vascular and microvascular anastomoses are critical components of reconstructive microsurgery, vascular surgery, and transplant surgery. Intraoperative surgical guidance using a surgical imaging modality that provides an in-depth view and three-dimensional (3-D) imaging can potentially improve outcome following both conventional and innovative anastomosis techniques. Objective postoperative imaging of the anastomosed vessel can potentially improve the salvage rate when combined with other clinical assessment tools, such as capillary refill, temperature, blanching, and skin turgor. Compared to other contemporary postoperative monitoring modalities—computed tomography angiograms, magnetic resonance (MR) angiograms, and ultrasound Doppler—optical coherence tomography (OCT) is a noninvasive high-resolution (micron-level), high-speed, 3-D imaging modality that has been adopted widely in biomedical and clinical applications. For the first time, to the best of our knowledge, the feasibility of real-time 3-D phase-resolved Doppler OCT (PRDOCT) as an assisted intra- and postoperative imaging modality for microvascular anastomosis of rodent femoral vessels is demonstrated, which will provide new insights and a potential breakthrough to microvascular and supermicrovascular surgery. PMID:23856833
Walter Reed Army Medical Center's Internet-based electronic health portal.
Abbott, Kevin C; Boocks, Carl E; Sun, Zhengyi; Boal, Thomas R; Poropatich, Ronald K
2003-12-01
Use of the World Wide Web (WWW) and electronic media to facilitate medical care has been the subject of many reports in the popular press. However, few reports have documented the results of implementing electronic health portals for essential medical tasks, such as prescription refills and appointments. At Walter Reed Army Medical Center, "Search & Learn" medical information, Internet-based prescription refills and patient appointments were established in January 2001. A multiphase retrospective analysis was conducted to determine the use of the "Search & Learn" medical information and the relative number of prescription refills and appointments conducted via the WWW compared with conventional methods. From January 2001 to May 2002, there were 34,741 refills and 819 appointments made over the Internet compared with 2,275,112 refills and approximately 500,000 appointments made conventionally. WWW activity accounted for 1.52% of refills and 0.16% of appointments. There was a steady increase in this percentage over the time of the analysis. In April of 2002, the monthly average of online refills had risen to 4.57% and online appointments were at 0.27%. Online refills were projected to account for 10% of all prescriptions in 2 years. The "Search & Learn" medical information portion of our web site received 147,429 unique visits during this same time frame, which was an average of 326 visitors per day. WWW-based methods of conducting essential medical tasks accounted for a small but rapidly increasing percentage of total activity at Walter Reed Army Medical Center. Subsequent phases of analysis will assess demographic and geographic factors and aid in the design of future systems to increase use of the Internet-based systems.
27 CFR 31.201 - Refilling of liquor bottles.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Bottles § 31.201 Refilling of liquor bottles. No person who sells, or offers for sale, distilled spirits... or increase any portion of the original contents contained in that bottle at the time of closing...
21 CFR 171.7 - Withdrawal of petition without prejudice.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Section 171.7 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES.... Upon refiling, the time limitation will begin to run anew from the date of refiling. (b) At any time... limitation will begin to run anew. (c) Any petitioner who has a food additive petition pending before the...
21 CFR 171.7 - Withdrawal of petition without prejudice.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Section 171.7 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES.... Upon refiling, the time limitation will begin to run anew from the date of refiling. (b) At any time... limitation will begin to run anew. (c) Any petitioner who has a food additive petition pending before the...
Anoje, Chukwuemeka; Agu, Kenneth Anene; Oladele, Edward A; Badru, Titilope; Adedokun, Oluwasanmi; Oqua, Dorothy; Khamofu, Hadiza; Adebayo, Olufunso; Torpey, Kwasi; Chabikuli, Otto Nzapfurundi
2017-02-01
Medication adherence is a major determinant of antiretroviral treatment (ART) success. Promptness in medication refill pick-ups may give an indication of medication adherence. This study determined medication refill adherence among HIV positive patients on ART and its association with treatment outcomes in HIV treatment centers in Nigeria. This retrospective multi-center cohort study involved a review of ART refill records for 3534 HIV-positive patients aged 18-60 years who initiated first-line ART between January 2008 and December 2009 and were on therapy for ≥18 months after ART initiation. Drug refill records of these patients for 10 consecutive refill visits after ART initiation were analyzed. The first ten consecutive refill appointment-keeping rates after ART initiation ranged from 64.3 % to 76.1 % which decreased with successive visits. Altogether, 743 (21.1 %) patients were deemed adherent, meaning they picked up their drugs within 7 days of the drug refill appointment date on at least nine out of ten refill visits. The adherent group of patients had a mean CD4 cells increase of 206 ± 6.1 cells/dl after 12 months of ART compared to 186 ± 7.1 cells/dl reported among the nonadherent group (p = 0.0145). The proportion of patients in the adherent category who showed no OIs after 12 months on ART (81 %) was significantly higher when compared to the proportion in the non-adherent category (23.5 %), (p = 0.008). The multivariate analysis showed that the odds of being adherent was 2-3 times more in patients who had a baseline CD4 count of less than 200 cells/dl compared to those with a baseline CD4 of >350 cells/dl. (AOR 2.43, 95 % CI 1.62-3.66). In addition, for patients with baseline CD4 cell count of 201-350 cells/dl, the odds of being adherent was found to be 1.9 compared to those with baseline CD4 of greater than 350 cells/dl (AOR 1.93, 95 % CI 1.27-2.94). Pharmacy refill data can serve as an adherence measure. Adherence to on-time drug pickup on ≥90 % of refill appointments was associated with a better CD4 count response and a reduction in the presence of opportunistic infections in ART patients after 12 months of treatment.
Modeling Electric Field Influences on Plasmaspheric Refilling
NASA Technical Reports Server (NTRS)
Liemohn, M. W.; Kozyra, J. U.; Khazanov, G. V.; Craven, Paul D.
1998-01-01
We have a new model of ion transport that we have applied to the problem of plasmaspheric flux tube refilling after a geomagnetic disturbance. This model solves the Fokker-Planck kinetic equation by applying discrete difference numerical schemes to the various operators. Features of the model include a time-varying ionospheric source, self-consistent Coulomb collisions, field-aligned electric field, hot plasma interactions, and ion cyclotron wave heating. We see refilling rates similar to those of earlier observations and models, except when the electric field is included. In this case, the refilling rates can be quite different that previously predicted. Depending on the populations included and the values of relevant parameters, trap zone densities can increase or decrease. In particular, the inclusion of hot populations near the equatorial region (specifically warm pancake distributions and ring current ions) can dramatically alter the refilling rate. Results are compared with observations as well as previous hydrodynamic and kinetic particle model simulations.
Nicotine Concentrations in Electronic Cigarette Refill and Do-It-Yourself Fluids
Davis, Barbara; Dang, Michael; Kim, Jisoo
2015-01-01
Introduction: We evaluated the accuracy of nicotine concentration labeling on electronic cigarette refill products. Methods: The nicotine concentration of 71 electronic cigarette refill fluid products and 1 related do-it-yourself (DIY) product was quantified using high-performance liquid chromatography. Quantified data were compared with manufacturers labeled concentrations. Duplicate refill fluid products purchased at different times were evaluated by visual comparison of fluid coloration and quantified nicotine concentration. Results: Thirty-five of the 54 nicotine-containing fluids had quantified nicotine concentrations that deviated by more than ±10% from the manufacturer labels, with 46 of 50 being in excess of labeled values. Refill fluids labeled as 0 nicotine had no detectable nicotine. Of the 5 products that were unlabeled for nicotine concentration, 3 contained no detectable nicotine, whereas the remaining 2 contained nicotine in excess of 100mg/ml and may have been intended for DIY use. Sixteen of the 18 duplicate bottles of refill fluid varied greatly in their nicotine concentrations. One of the 5 companies showed significant improvement in labeling accuracy among the most recently purchased products. Of the 23 total duplicate pairs, 15 of 23 varied in coloration from their mates. Conclusions: Nicotine concentration labeling on electronic cigarette refill products was often inaccurate but showed improvement recently in products from 1 company. To ensure the safety of refill fluids and DIY products, it is necessary to establish quality control guidelines for the manufacturing and labeling and to monitor products longitudinally. PMID:24862971
[Alarm symptoms of meningitis in children with fever].
Geurts, Dorien H F; Moll, Henriette A
2011-01-01
A 15-year-old girl presented with fever and pain in her legs. A viral infection was suspected, but within 24 hours she became confused and developed meningeal signs, based on which she was diagnosed as having meningitis. Within a few hours a 6-month-old boy developed fever, a grey colour, bulging fontanel, cold hands and feet, and was groaning. He too appeared to have meningitis. It is important to recognize this serious infection in children with fever, since delay of diagnosis and treatment may result in serious complications. Recognition is difficult because of non-specific symptoms on presentation and a lack of alarm symptoms early in the course of the disease. Alarm symptoms of serious infection in children are cyanosis, rapid breathing, decreased capillary refill, petechial rash, meningeal signs, leg pain and decreased consciousness. If serious infection is uncertain in a child with fever, parents should be advised on the potential course of the disease, the alarm symptoms and the need to seek medical help in time.
Understanding prescription adherence: Pharmacy claims data from the Contraceptive CHOICE Project
Pittman, Meredith E.; Secura, Gina M.; Allsworth, Jenifer E.; Homco, Juell B.; Madden, Tessa; Peipert, Jeffrey F.
2010-01-01
BACKGROUND We examined prescription adherence rates by contraceptive method among women who used oral contraceptive pills (OCP), transdermal patch, or vaginal ring. STUDY DESIGN Women in the St. Louis area were provided their choice of OCP, patch, or ring at no cost and followed for 18 months. Time between monthly refills was obtained from pharmacy data and analyzed as a marker of adherence. Risk factors for initial nonadherence were estimated using Cox proportional hazards; predictors for repeated nonadherence were analyzed using Poisson regression with robust error variance. RESULTS Overall, 619 participants filled 6,435 contraceptive prescriptions with a median of 10 refills per participant. Only 30% of women (n=187) obtained all refills on time. In the time-to-failure analysis, use of vaginal ring and increased parity were predictors of early nonadherence (p<0.05). In the multivariable analysis, use of the vaginal ring and history of abortion were risk factors for repeated nonadherence (p<0.01). CONCLUSIONS Even with financial barriers removed, pharmacy data show that many women inconsistently refill their contraception and may be at risk for unintended pregnancy. PMID:21397092
de Vos-Kerkhof, Evelien; Krecinic, Tarik; Vergouwe, Yvonne; Moll, Henriëtte A; Nijman, Ruud G; Oostenbrink, Rianne
2017-01-01
To determine the agreement between peripheral and central capillary refill time (pCRT/cCRT) and their diagnostic values for detecting serious bacterial infection (SBI) in febrile children attending the paediatric emergency department (ED). Prospective observational study. Paediatric ED, Erasmus Medium Care-Sophia Children's hospital, the Netherlands. 1193 consecutively included, previously healthy, febrile children (1 month-16 years) with both pCRT measurements and cCRT measurements available. SBI diagnosis was based on abnormal radiographic findings and/or positive cultures from normally sterile locations in addition to clinical criteria. Agreement between pCRT and cCRT (Cohen's κ), overall and stratified for age and body temperature. The diagnostic value of pCRT and cCRT for SBI was assessed with logistic regression. Overall agreement was 0.35 (95% CI 0.27 to 0.43; considered 'fair'). Although not significant, agreement was lower in children aged 1-<5 years (κ: 0.15 (95% CI 0.04 to 0.27)) and decreased with higher body temperatures with κ ranging from 0.55 (95% CI 0.32 to 0.79) for temperature <37.5°C to 0.21 (95% CI 0.07 to 0.34) for temperature >39.5°C. Abnormal pCRT (>2 s) was observed in 153 (12.8%; 95% CI 10.9% to 14.7%) and abnormal cCRT in 55 (4.6%; 95% CI 3.4% to 5.8%) children. The OR of abnormal pCRT (>2 s) for predicting SBI was 1.10 (95% CI 0.65 to 1.84). For abnormal cCRT (>2 s), the OR was 0.43 (95% CI 0.13 to 1.39). The pCRT and cCRT values showed only fair agreement in a general population of febrile children at the ED, and no significant association with age or body temperature was found. Only a small part of febrile children at risk for serious infections at the ED show abnormal CRT values. Both abnormal pCRT and cCRT (defined as >2 s) performed poorly and were non-significant in this study detecting SBI in a general population of febrile children. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Chen, Chao-Jung; Chen, Wei-Yun; Tseng, Mei-Chun; Chen, Yet-Ran
2012-01-03
In this study, an easy method to fabricate a durable in-capillary frit was developed for use in nanoflow liquid chromatography (nanoLC). A small orifice was tunneled into the sol-gel frit during the polymerization process resulting in the simple fabrication of a tunnel frit. A short packing tunnel frit column (2 cm, C(18) particles) was able to sustain over 10,000 psi continuous liquid flow for 10 days without observation of particle loss, and back pressure variation was less than 5%. The tunnel frit was successfully applied to the fabrication of nanoflow ultra high-performance liquid chromatography (nano-UHPLC) trap and analytical columns. In the analysis of tryptic peptides, the tunnel frit trap and analytical columns were demonstrated to have high separation efficiency and sensitivity. In analysis of phosphopeptides, the use of the nonmetallic tunnel frit column showed better sensitivity than the metallic frit column. This design can facilitate the preparation of nano-HPLC and nano-UHPLC columns and the packing material can easily be refilled when the column is severely contaminated or clogged. © 2011 American Chemical Society
Nicotine concentrations in electronic cigarette refill and do-it-yourself fluids.
Davis, Barbara; Dang, Michael; Kim, Jisoo; Talbot, Prue
2015-02-01
We evaluated the accuracy of nicotine concentration labeling on electronic cigarette refill products. The nicotine concentration of 71 electronic cigarette refill fluid products and 1 related do-it-yourself (DIY) product was quantified using high-performance liquid chromatography. Quantified data were compared with manufacturers labeled concentrations. Duplicate refill fluid products purchased at different times were evaluated by visual comparison of fluid coloration and quantified nicotine concentration. Thirty-five of the 54 nicotine-containing fluids had quantified nicotine concentrations that deviated by more than ± 10% from the manufacturer labels, with 46 of 50 being in excess of labeled values. Refill fluids labeled as 0 nicotine had no detectable nicotine. Of the 5 products that were unlabeled for nicotine concentration, 3 contained no detectable nicotine, whereas the remaining 2 contained nicotine in excess of 100mg/ml and may have been intended for DIY use. Sixteen of the 18 duplicate bottles of refill fluid varied greatly in their nicotine concentrations. One of the 5 companies showed significant improvement in labeling accuracy among the most recently purchased products. Of the 23 total duplicate pairs, 15 of 23 varied in coloration from their mates. Nicotine concentration labeling on electronic cigarette refill products was often inaccurate but showed improvement recently in products from 1 company. To ensure the safety of refill fluids and DIY products, it is necessary to establish quality control guidelines for the manufacturing and labeling and to monitor products longitudinally. © The Author 2014. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Refilling of a Hydraulically Isolated Embolized Xylem Vessel: Model Calculations
VESALA, TIMO; HÖLTTÄ, TEEMU; PERÄMÄKI, MARTTI; NIKINMAA, EERO
2003-01-01
When they are hydraulically isolated, embolized xylem vessels can be refilled, while adjacent vessels remain under tension. This implies that the pressure of water in the refilling vessel must be equal to the bubble gas pressure, which sets physical constraints for recovery. A model of water exudation into the cylindrical vessel and of bubble dissolution based on the assumption of hydraulic isolation is developed. Refilling is made possible by the turgor of the living cells adjacent to the refilling vessel, and by a reflection coefficient below 1 for the exchange of solutes across the interface between the vessel and the adjacent cells. No active transport of solutes is assumed. Living cells are also capable of importing water from the water‐conducting vessels. The most limiting factors were found to be the osmotic potential of living cells and the ratio of the volume of the adjacent living cells to that of the embolized vessel. With values for these of 1·5 MPa and 1, respectively, refilling times were in the order of hours for a broad range of possible values of water conductivity coefficients and effective diffusion distances for dissolved air, when the xylem water tension was below 0·6 MPa and constant. Inclusion of the daily pattern for xylem tension improved the simulations. The simulated gas pressure within the refilling vessel was in accordance with recent experimental results. The study shows that the refilling process is physically possible under hydraulic isolation, while water in surrounding vessels is under negative pressure. However, the osmotic potentials in the refilling vessel tend to be large (in the order of 1 MPa). Only if the xylem water tension is, at most, twice atmospheric pressure, the reflection coefficient remains close to 1 (0·95) and the ratio of the volume of the adjacent living cells to that of the embolized vessel is about 2, does the osmotic potential stay below 0·4 MPa. PMID:12588721
Economical and ecological comparison of granular activated carbon (GAC) adsorber refill strategies.
Bayer, Peter; Heuer, Edda; Karl, Ute; Finkel, Michael
2005-05-01
Technical constraints can leave a considerable freedom in the design of a technology, production or service strategy. Choosing between economical or ecological decision criteria then characteristically leads to controversial solutions of ideal systems. For the adaptation of granular-activated carbon (GAC) fixed beds, various technical factors determine the adsorber volume required to achieve a desired service life. In considering carbon replacement and recycling, a variety of refill strategies are available that differ in terms of refill interval, respective adsorber volume, and time-dependent use of virgin, as well as recycled GAC. Focusing on the treatment of contaminant groundwater, we compare cost-optimal reactor configurations and refill strategies to the ecologically best alternatives. Costs and consumption of GAC are quantified within a technical-economical framework. The emissions from GAC production out of hard coal, transport and recycling are equally derived through a life cycle impact assessment. It is shown how high discount rates lead to a preference of small fixed-bed volumes, and accordingly, a high number of refills. For fixed discount rates, the investigation reveals that both the economical as well as ecological assessment of refill strategies are especially sensitive to the relative valuation of virgin and recycled GAC. Since recycling results in economic and ecological benefits, optimized systems thus may differ only slightly.
Effects of a direct refill program for automated dispensing cabinets on medication-refill errors.
Helmons, Pieter J; Dalton, Ashley J; Daniels, Charles E
2012-10-01
The effects of a direct refill program for automated dispensing cabinets (ADCs) on medication-refill errors were studied. This study was conducted in designated acute care areas of a 386-bed academic medical center. A wholesaler-to-ADC direct refill program, consisting of prepackaged delivery of medications and bar-code-assisted ADC refilling, was implemented in the inpatient pharmacy of the medical center in September 2009. Medication-refill errors in 26 ADCs from the general medicine units, the infant special care unit, the surgical and burn intensive care units, and intermediate units were assessed before and after the implementation of this program. Medication-refill errors were defined as an ADC pocket containing the wrong drug, wrong strength, or wrong dosage form. ADC refill errors decreased by 77%, from 62 errors per 6829 refilled pockets (0.91%) to 8 errors per 3855 refilled pockets (0.21%) (p < 0.0001). The predominant error type detected before the intervention was the incorrect medication (wrong drug, wrong strength, or wrong dosage form) in the ADC pocket. Of the 54 incorrect medications found before the intervention, 38 (70%) were loaded in a multiple-drug drawer. After the implementation of the new refill process, 3 of the 5 incorrect medications were loaded in a multiple-drug drawer. There were 3 instances of expired medications before and only 1 expired medication after implementation of the program. A redesign of the ADC refill process using a wholesaler-to-ADC direct refill program that included delivery of prepackaged medication and bar-code-assisted refill significantly decreased the occurrence of ADC refill errors.
Monitoring peripheral perfusion and microcirculation.
Dubin, Arnaldo; Henriquez, Elizabeth; Hernández, Glenn
2018-06-01
Microcirculatory alterations play a major role in the pathogenesis of shock. Monitoring tissue perfusion might be a relevant goal for shock resuscitation. The goal of this review was to revise the evidence supporting the monitoring of peripheral perfusion and microcirculation as goals of resuscitation. For this purpose, we mainly focused on skin perfusion and sublingual microcirculation. Although there are controversies about the reproducibility of capillary refill time in monitoring peripheral perfusion, it is a sound physiological variable and suitable for the ICU settings. In addition, observational studies showed its strong ability to predict outcome. Moreover, a preliminary study suggested that it might be a valuable goal for resuscitation. These results should be confirmed by the ongoing ANDROMEDA-SHOCK randomized controlled trial. On the other hand, the monitoring of sublingual microcirculation might also provide relevant physiological and prognostic information. On the contrary, methodological drawbacks mainly related to video assessment hamper its clinical implementation at the present time. Measurements of peripheral perfusion might be useful as goal of resuscitation. The results of the ANDROMEDA-SHOCK will clarify the role of skin perfusion as a guide for the treatment of shock. In contrast, the assessment of sublingual microcirculation mainly remains as a research tool.
Yamany, Abeer; Hamdy, Bassant
2016-01-01
[Purpose] The aim of this study was to investigate the effects of sequential pneumatic compression therapy on venous blood flow, refilling time, pain level, and quality of life in women with varicose veins. [Subjects and Methods] Twenty-eight females with varicose veins were selected and randomly allocated to a control group, and experimental group. Maximum and mean venous blood velocities, the refilling time, pain by visual analog scale and quality of life by Aberdeen Varicose Veins Questionnaire were measured in all patients before and after six weeks of treatment. Both groups received lower extremity exercises; in addition, patients in the experimental group received sequential pneumatic compression therapy for 30 minutes daily, five days a week for six weeks. [Results] All measured parameters improved significantly in both groups, comparison of post treatment measurements between groups showed that the maximum and mean blood flow velocity, the pain level, and quality of life were significantly higher in the experimental group compared with the control group. On the other hand there was no significant difference between groups for refilling time. [Conclusion] Sequential pneumatic compression therapy with the applied parameters was an effective modality for increasing venous blood flow, reducing pain, and improving quality of women life with varicose veins. PMID:27512247
Energy contribution of sugar-sweetened beverage refills at fast-food restaurants.
Breck, Andrew; Cantor, Jonathan H; Elbel, Brian
2017-09-01
To identify demographic and consumer characteristics associated with refilling a soft drink at fast-food restaurants and the estimated energy content and volume of those refills. Logistic and linear regression with cross-sectional survey data. Data include fast-food restaurant receipts and consumer surveys collected from restaurants in New York City (all boroughs except Staten Island), and Newark and Jersey City, New Jersey, during 2013 and 2014. Fast-food restaurant customers (n 11795) from ninety-eight restaurants. Thirty per cent of fast-food customers ordered a refillable soft drink. Nine per cent of fast-food customers with a refillable soft drink reported refilling their beverage (3 % of entire sample). Odds of having a beverage refill were higher among respondents with a refillable soft drink at restaurants with a self-serve refill kiosk (adjusted OR (aOR)=7·37, P<0·001) or who ate in the restaurant (aOR=4·45, P<0·001). KFC (aOR=2·18, P<0·001) and Wendy's (aOR=0·41, P<0·001) customers had higher and lower odds, respectively, of obtaining a refill, compared with Burger King customers. Respondents from New Jersey (aOR=1·47, P<0·001) also had higher odds of refilling their beverage than New York City customers. Customers who got a refill obtained on average 29 more 'beverage ounces' (858 ml) and 250 more 'beverage calories' (1046 kJ) than customers who did not get a refill. Refilling a beverage was associated with having obtained more beverage calories and beverage ounces. Environmental cues, such as the placement and availability of self-serve beverage refills, may influence consumer beverage choice.
21 CFR 1306.22 - Refilling of prescriptions.
Code of Federal Regulations, 2010 CFR
2010-04-01
... refilled, the quantity dispensed, initials of the dispensing pharmacist for each refill, and the total number of refills for that prescription. If the pharmacist merely initials and dates the back of the... original prescription through an oral refill authorization transmitted to the pharmacist provided the...
Moreno, Gerardo; Lin, Elizabeth H; Chang, Eva; Johnson, Ron L; Berthoud, Heidi; Solomon, Cam C; Morales, Leo S
2016-03-01
Health systems are increasingly implementing remote telephone and Internet refill systems to enhance patient access to medication refills. Remote refill systems may provide an effective approach for improving medication non-adherence, but more research is needed among patients with limited English proficiency with poor access to remote refill systems. To compare the use of remote medication refill systems among limited-English-proficiency (LEP) and English-proficient (EP) patients with chronic conditions. Cross-sectional survey in six languages/dialects (English, Cantonese, Mandarin, Korean, Vietnamese, and Spanish) of 509 adults with diabetes, hypertension, or hyperlipidemia. Primary study outcomes were self-reported use of 1) Internet refills, 2) telephone refills, and 3) any remote refill system. LEP was measured by patient self-identification of a primary language other than English and a claims record of use of an interpreter. Other measures were age, gender, education, years in the U.S., insurance, health status, chronic conditions, and number of prescribed medications. Analyses included multivariable logistic regression weighted for survey non-response. Overall, 33.1 % of patients refilled their medications by telephone and 31.6 % by Internet. Among LEP patients (n = 328), 31.5 % refilled by telephone and 21.2 % by Internet, compared with 36.7 % by telephone and 52.7 % by Internet among EP patients (n = 181). Internet refill by language groups were as follows: English (52.7 %), Cantonese (34.9 %), Mandarin (17.4 %), Korean (16.7 %), Vietnamese (24.4 %), and Spanish (12.6 %). Compared to EP patients, LEP patients had lower use of any remote refill system (adjusted odds ratio [AOR] 0.18; p < 0.001), CONCLUSIONS: LEP patients are significantly less likely than EP patients to use any remote medication refill system. Increased reliance on current systems for remote medication refills may increase disparities in health outcomes affecting LEP patients with poor access to telephone and Internet medication refills.
NASA Astrophysics Data System (ADS)
Denton, R. E.; Wang, Y.; Webb, P. A.; Tengdin, P. M.; Goldstein, J.; Redfern, J. A.; Reinisch, B. W.
2012-03-01
Using measurements of the electron density ne found from passive radio wave observations by the IMAGE spacecraft RPI instrument on consecutive passes through the magnetosphere, we calculate the long-term (>1 day) refilling rate of equatorial electron density dne,eq/dt from L = 2 to 9. Our events did not exhibit saturation, probably because our data set did not include a deep solar minimum and because saturation is an unusual occurrence, especially outside of solar minimum. The median rate in cm-3/day can be modeled with log10(dne,eq/dt) = 2.22 - 0.006L - 0.0347L2, while the third quartile rate can be modeled with log10(dne,eq/dt) = 3.39 - 0.353L, and the mean rate can be modeled as log10(dne,eq/dt) = 2.74 - 0.269L. These statistical values are found from the ensemble of all observed rates at each L value, including negative rates (decreases in density due to azimuthal structure or radial motion or for other reasons), in order to characterize the typical behavior. The first quartile rates are usually negative for L < 4.7 and close to zero for larger L values. Our rates are roughly consistent with previous observations of ion refilling at geostationary orbit. Most previous studies of refilling found larger refilling rates, but many of these examined a single event which may have exhibited unusually rapid refilling. Comparing refilling rates at solar maximum to those at solar minimum, we found that the refilling rate is larger at solar maximum for small L < 4, about the same at solar maximum and solar minimum for L = 4.2 to 5.8, and is larger at solar minimum for large L > 5.8 such as at geostationary orbit (L ˜ 6.8) (at least to L of about 8). These results agree with previous results for ion refilling at geostationary orbit, may agree with previous results at lower L, and are consistent with some trends for ionospheric density.
40 CFR 165.67 - Registrants who distribute or sell pesticide products to refillers for repackaging.
Code of Federal Regulations, 2010 CFR
2010-07-01
... residue from a refillable container (portable or stationary pesticide container) before it is refilled. (i... application, the refilling residue removal procedure must describe how to manage any rinsate resulting from... description of acceptable refillable containers (portable or stationary pesticide containers) that can be used...
Sinyavskaya, Liliya; Matteau, Alexis; Johnson, Sarasa; Durand, Madeleine
2018-06-05
Algorithms to define current exposure to warfarin using administrative data may be imprecise. Study objectives were to characterize dispensation patterns, to measure gaps between expected and observed refill dates for warfarin and direct oral anticoagulants (DOACs). Retrospective cohort study using administrative health care databases of the Régie de l'assurance-maladie du Québec. We identified every dispensation of warfarin, dabigatran, rivaroxaban, or apixaban for patients with AF initiating oral anticoagulants between 2010 and 2015. For each dispensation, we extracted date and duration. Refill gaps were calculated as difference between expected and observed dates of successive dispensation. Refill gaps were summarized using descriptive statistics. To account for repeated observations nested within patients and to assess the components of variance of refill gaps, we used unconditional multilevel linear models. We identified 61 516 new users. Majority were prescribed warfarin (60.3%), followed by rivaroxaban (16.4%), dabigatran (14.5%), apixaban (8.8%). Most frequent recorded duration of dispensation was 7 days, suggesting use of pharmacist-prepared weekly pillboxes. The average refill gap from multilevel model was higher for warfarin (9.28 days, 95%CI:8.97-9.59) compared with DOACs (apixaban 3.08 days, 95%CI: 2.96-3.20, dabigatran 3.70, 95%CI: 3.56-3.84, rivaroxaban 3.15, 95%CI: 3.03-3.27). The variance of refill gaps was greater among warfarin users than among DOAC users. Greater refill gaps for warfarin may reflect inadequate capture of the period covered by the number of dispensed pills recorded in administrative data. A time-dependent definition of exposure using dispensation data would lead to greater misclassification of warfarin than DOACs use. Copyright © 2018 John Wiley & Sons, Ltd.
Transdermal power transfer for recharging implanted drug delivery devices via the refill port.
Evans, Allan T; Chiravuri, Srinivas; Gianchandani, Yogesh B
2010-04-01
This paper describes a system for transferring power across a transdermal needle into a smart refill port for recharging implantable drug delivery systems. The device uses a modified 26 gauge (0.46 mm outer diameter) Huber needle with multiple conductive elements designed to couple with mechanical springs in the septum of the refill port of a drug delivery device to form an electrical connection that can sustain the current required to recharge a battery during a reservoir refill session. The needle is fabricated from stainless steel coated with Parylene, and the refill port septum is made from micromachined stainless steel contact springs and polydimethylsiloxane. The device properties were characterized with dry and wet ambient conditions. The needle and port pair had an average contact resistance of less than 2 Omega when mated in either environment. Electrical isolation between the system, the liquid in the needle lumen, and surrounding material has been demonstrated. The device was used to recharge a NiMH battery with currents up to 500 mA with less than 15 degrees C of resistive heating. The system was punctured 100 times to provide preliminary information with regard to device longevity, and exhibited about 1 Omega variation in contact resistance. The results suggest that this needle and refill port system can be used in an implant to enable battery recharging. This allows for smaller batteries to be used and ultimately increases the volume efficiency of an implantable drug delivery device.
Studies on Equatorial Shock Formation During Plasmaspheric Refilling
NASA Technical Reports Server (NTRS)
Singh, Nagendra
1995-01-01
During the grant period from August 1, 1994 to October 31, 1995 we have continued to investigate the effects of plasma wave instabilities on the early stage plasmaspheric refilling. Since ion beams are the primary feature of the interhemispheric plasma flows during the early stage refilling, ion-beam driven instabilities and associated waves are of primary interest. The major findings of this research are briefly summarized here. After a systematic examination of the relevant plasma instabilities, we realized that when the interhemispheric plasma flows begin to interpenetrate at the equator, the most relevant plasma instability is the electrostatic ion cyclotron wave instability. Only at later stages the ion-acoustic instability may be affecting the plasma flow. An interesting property of the electrostatic ion cyclotron wave is that it heats ions perpendicular to the magnetic field. When the ions in the field-aligned flows are transversely heated, they are trapped in the magnetic flux tube, thus affecting the refilling process. The eic wave instability is a microprocess with scale length of the order of ion Larmor radius and the corresponding time scale is the ion cyclotron period. We have attempted to tackle the problem for the plasmaspheric refilling by incorporating the effects of eic wave instability on the mesoscale plasma flow when the properties of the latter exceeds the critical conditions for the former. We have compared the results on refilling from the model with and without the eic instability effects.
Forming electrical interconnections through semiconductor wafers
NASA Technical Reports Server (NTRS)
Anthony, T. R.
1981-01-01
An information processing system based on CMOS/SOS technology is being developed by NASA to process digital image data collected by satellites. An array of holes is laser drilled in a semiconductor wafer, and a conductor is formed in the holes to fabricate electrical interconnections through the wafers. Six techniques are used to form conductors in the silicon-on-sapphire (SOS) wafers, including capillary wetting, wedge extrusion, wire intersection, electroless plating, electroforming, double-sided sputtering and through-hole electroplating. The respective strengths and weaknesses of these techniques are discussed and compared, with double-sided sputtering and the through-hole plating method achieving best results. In addition, hollow conductors provided by the technique are available for solder refill, providing a natural way of forming an electrically connected stack of SOS wafers.
26 CFR 400.1-1 - Refiling of notice of tax lien.
Code of Federal Regulations, 2010 CFR
2010-04-01
... notice of lien is refiled in the office in which the prior notice of lien (including a refiled notice... his change in residence to N State more than 89 days prior to the date refiling of the notice of lien... to R State was the most recent notice received more than 89 days prior to the date refiling in O...
Natarajan, Seenivasan; Stamps, Robert H; Ma, Lena Q; Saha, Uttam K; Hernandez, Damaris; Cai, Yong; Zillioux, Edward J
2011-01-30
A large-scale hydroponic system to phytoremediate arsenic-contaminated groundwater using Pteris vittata (Chinese brake fern) was successfully tested in a field. In this 30-wk study, three frond-harvesting regimes (all, mature, and senescing fronds) and two water-refilling schemes to compensate for evapotranspiration (high-As water of 140-180 μg/L and low-As water of <7 μg/L) were investigated. Two experiments (Cycle 1 and Cycle 2) were conducted using the same plants in 24 tanks with each containing 600 L of arsenic-contaminated groundwater and 32 ferns. During Cycle 1 and with initial As of 140 μg/L, As in tanks refilled with low-As water was reduced to <10 μg/L in 8 wks compared to <10 μg/L in 17 wks in tanks refilled with high-As water. During Cycle 2 and with initial As of 180 μg/L, the remediation time was reduced by 2-5 wks, indicating that more established ferns were more efficient. In areas where clean water is limiting, refilling high-As water coupled with harvesting senescing fronds is recommended for more effective As phytoremediation. Published by Elsevier B.V.
Code of Federal Regulations, 2011 CFR
2011-07-01
... repackaging of agricultural pesticides performed by refilling establishments subcategory. 455.60 Section 455... STANDARDS PESTICIDE CHEMICALS Repackaging of Agricultural Pesticides Performed at Refilling Establishments § 455.60 Applicability; description of repackaging of agricultural pesticides performed by refilling...
Code of Federal Regulations, 2010 CFR
2010-07-01
... repackaging of agricultural pesticides performed by refilling establishments subcategory. 455.60 Section 455... STANDARDS PESTICIDE CHEMICALS Repackaging of Agricultural Pesticides Performed at Refilling Establishments § 455.60 Applicability; description of repackaging of agricultural pesticides performed by refilling...
Freeman, D A; Cymbaluk, N F; Schott, H C; Hinchcliff, K; McDonnell, S M; Kyle, B
1999-11-01
To compare health, hydration status, and management of stabled pregnant mares provided drinking water continuously or via 1 of 3 intermittent delivery systems. 22 Quarter Horse (QH) or QH-crossbred mares and 18 Belgian or Belgian-crossbred mares (study 1); 24 QH or QH-crossbred mares and 18 Belgian or Belgian-crossbred mares (study 2). Stabled horses were provided water continuously or via 1 of 3 intermittent water delivery systems in 2 study periods during a 2-year period. Body temperature, attitude, appetite, water intake, and urine output were recorded daily. Hygiene of each horse and the stable were assessed weekly. Clinical and biochemical measures of hydration were determined 3 times during each study. Clinical measures of hydration included skin turgor, gum moisture, capillary refill time, and fecal consistency. Biochemical measures of hydration included PCV, plasma total protein concentration, serum osmolality, plasma vasopressin concentration, urine specific gravity, and urine osmolality. All horses remained healthy. Stable hygiene was worse when horses had continuous access to water. Clinical and biochemical measures of hydration did not differ among water delivery systems. Various continuous and intermittent water delivery systems provided adequate amounts of water to stabled horses to maintain health and hydration status. Providing intermittent access to water may be preferable on the basis of stable hygiene.
21 CFR 1306.22 - Refilling of prescriptions.
Code of Federal Regulations, 2013 CFR
2013-04-01
... pharmacist for each refill. (5) The total number of refills for that prescription. (d) If the pharmacist... original prescription through an oral refill authorization transmitted to the pharmacist provided the... prescription. (2) The pharmacist obtaining the oral authorization records on the reverse of the original paper...
21 CFR 1306.22 - Refilling of prescriptions.
Code of Federal Regulations, 2012 CFR
2012-04-01
... pharmacist for each refill. (5) The total number of refills for that prescription. (d) If the pharmacist... original prescription through an oral refill authorization transmitted to the pharmacist provided the... prescription. (2) The pharmacist obtaining the oral authorization records on the reverse of the original paper...
21 CFR 1306.22 - Refilling of prescriptions.
Code of Federal Regulations, 2011 CFR
2011-04-01
... pharmacist for each refill. (5) The total number of refills for that prescription. (d) If the pharmacist... original prescription through an oral refill authorization transmitted to the pharmacist provided the... prescription. (2) The pharmacist obtaining the oral authorization records on the reverse of the original paper...
21 CFR 1306.22 - Refilling of prescriptions.
Code of Federal Regulations, 2014 CFR
2014-04-01
... pharmacist for each refill. (5) The total number of refills for that prescription. (d) If the pharmacist... original prescription through an oral refill authorization transmitted to the pharmacist provided the... prescription. (2) The pharmacist obtaining the oral authorization records on the reverse of the original paper...
The switch to refillable bottled water in Indonesia: a serious health risk.
Komarulzaman, Ahmad; de Jong, Eelke; Smits, Jeroen
2017-10-01
In recent years, the consumption of refillable bottled water has increased considerably in emerging countries. However, the quality of this water is often questionable, as authorities lack the capacity to properly check refilling depots. Given that refillable bottled water not only replaces unimproved water sources, but also better-quality sources, like piped and branded bottled water, its increasing use poses a major health risk. We investigate the motives behind the decision to switch to refillable bottled water in Indonesia. Findings indicate that this switch is driven by lifestyle motives, as well as by cost and availability considerations. It is mostly the young affluent households who switch from piped and 'other' sources to refillable bottled water. In rural areas, the tendency to make this switch is negatively affected by availability problems and the higher price of refillable bottled water. Availability and cost also influence the switch from branded bottled to refillable bottled water, but here it is the poorer households who have a higher propensity to switch. Further exploration of the lifestyle motive and affordability issues, as well as better monitoring of the refilling depots, are needed to improve the quality of drinking water in Indonesia and other emerging countries.
Subramaniam, Hamsa L.; Prust, Margaret L.; Prescott, Marta R.; Mpasela, Felton; Mwango, Albert; Namonje, Leah; Moyo, Crispin; Chibuye, Benjamin; van den Broek, Jan Willem; Hehman, Lindsey; Moberley, Sarah
2017-01-01
Introduction In urban areas, crowded HIV treatment facilities with long patient wait times can deter patients from attending their clinical appointments and picking up their medications, ultimately disrupting patient care and compromising patient retention and adherence. Methods Formative research at eight facilities in Lusaka revealed that only 46% of stable HIV treatment patients were receiving a three-month refill supply of antiretroviral drugs, despite it being national policy for stable adult patients. We designed a quality improvement intervention to improve the operationalization of this policy. We conducted a cluster-randomized controlled trial in sixteen facilities in Lusaka with the primary objective of examining the intervention’s impact on the proportion of stable patients receiving three-month refills. The secondary objective was examining whether the quality improvement intervention reduced facility congestion measured through two proxy indicators: daily volume of clinic visits and average clinic wait times for services. Results The mean change in the proportion of three-month refills among control facilities from baseline to endline was 10% (from 38% to 48%), compared to a 25% mean change (an increase from 44% to 69%) among intervention facilities. This represents a significant 15% mean difference (95% CI: 2%-29%; P = 0.03) in the change in proportion of patients receiving three-month refills. On average, control facilities had 15 more visits per day in the endline than in the baseline, while intervention facilities had 20 fewer visits per day in endline than in baseline, a mean difference of 35 fewer visits per day (P = 0.1). The change in the mean facility total wait time for intervention facilities dropped 19 minutes between baseline and endline when compared to control facilities (95% CI: -10.2–48.5; P = 0.2). Conclusion A more patient-centred service delivery schedule of three-month prescription refills for stable patients is viable. We encourage the expansion of this sustainable intervention in Zambia’s urban clinics. PMID:28419106
McCarthy, Elizabeth A; Subramaniam, Hamsa L; Prust, Margaret L; Prescott, Marta R; Mpasela, Felton; Mwango, Albert; Namonje, Leah; Moyo, Crispin; Chibuye, Benjamin; van den Broek, Jan Willem; Hehman, Lindsey; Moberley, Sarah
2017-01-01
In urban areas, crowded HIV treatment facilities with long patient wait times can deter patients from attending their clinical appointments and picking up their medications, ultimately disrupting patient care and compromising patient retention and adherence. Formative research at eight facilities in Lusaka revealed that only 46% of stable HIV treatment patients were receiving a three-month refill supply of antiretroviral drugs, despite it being national policy for stable adult patients. We designed a quality improvement intervention to improve the operationalization of this policy. We conducted a cluster-randomized controlled trial in sixteen facilities in Lusaka with the primary objective of examining the intervention's impact on the proportion of stable patients receiving three-month refills. The secondary objective was examining whether the quality improvement intervention reduced facility congestion measured through two proxy indicators: daily volume of clinic visits and average clinic wait times for services. The mean change in the proportion of three-month refills among control facilities from baseline to endline was 10% (from 38% to 48%), compared to a 25% mean change (an increase from 44% to 69%) among intervention facilities. This represents a significant 15% mean difference (95% CI: 2%-29%; P = 0.03) in the change in proportion of patients receiving three-month refills. On average, control facilities had 15 more visits per day in the endline than in the baseline, while intervention facilities had 20 fewer visits per day in endline than in baseline, a mean difference of 35 fewer visits per day (P = 0.1). The change in the mean facility total wait time for intervention facilities dropped 19 minutes between baseline and endline when compared to control facilities (95% CI: -10.2-48.5; P = 0.2). A more patient-centred service delivery schedule of three-month prescription refills for stable patients is viable. We encourage the expansion of this sustainable intervention in Zambia's urban clinics.
40 CFR 165.45 - Refillable container standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... at the refilling establishment of a refiller operating under written contract to you, the stationary..., and exclude precipitation. (ii) External sight gauges, which are pesticide-containing hoses or tubes... refillable container standards? Yes, it is possible for you to obtain a waiver from or a modification to some...
Uptake of water via branches helps timberline conifers refill embolized xylem in late winter.
Mayr, Stefan; Schmid, Peter; Laur, Joan; Rosner, Sabine; Charra-Vaskou, Katline; Dämon, Birgit; Hacke, Uwe G
2014-04-01
Xylem embolism is a limiting factor for woody species worldwide. Conifers at the alpine timberline are exposed to drought and freeze-thaw stress during winter, which induce potentially lethal embolism. Previous studies indicated that timberline trees survive by xylem refilling. In this study on Picea abies, refilling was monitored during winter and spring seasons and analyzed in the laboratory and in situ experiments, based on hydraulic, anatomical, and histochemical methods. Refilling started in late winter, when the soil was frozen and soil water not available for the trees. Xylem embolism caused up to 86.2% ± 3.1% loss of conductivity and was correlated with the ratio of closed pits. Refilling of xylem as well as recovery in shoot conductance started in February and corresponded with starch accumulation in secondary phloem and in the mesophyll of needles, where we also observed increasing aquaporin densities in the phloem and endodermis. This indicates that active, cellular processes play a role for refilling even under winter conditions. As demonstrated by our experiments, water for refilling was thereby taken up via the branches, likely by foliar water uptake. Our results suggest that refilling is based on water shifts to embolized tracheids via intact xylem, phloem, and parenchyma, whereby aquaporins reduce resistances along the symplastic pathway and aspirated pits facilitate isolation of refilling tracheids. Refilling must be taken into account as a key process in plant hydraulics and in estimating future effects of climate change on forests and alpine tree ecosystems.
Sedative and analgesic effects of intravenous xylazine and tramadol on horses
Seo, Jong-pil; Son, Won-gyun; Gang, Sujin
2011-01-01
This study was performed to evaluate the sedative and analgesic effects of xylazine (X) and tramadol (T) intravenously (IV) administered to horses. Six thoroughbred saddle horses each received X (1.0 mg/kg), T (2.0 mg/kg), and a combination of XT (1.0 and 2.0 mg/kg, respectively) IV. Heart rate (HR), respiratory rate (RR), rectal temperature (RT), indirect arterial pressure (IAP), capillary refill time (CRT), sedation, and analgesia (using electrical stimulation and pinprick) were measured before and after drug administration. HR and RR significantly decreased from basal values with X and XT treatments, and significantly increased with T treatment (p < 0.05). RT and IAP also significantly increased with T treatment (p < 0.05). CRT did not change significantly with any treatments. The onset of sedation and analgesia were approximately 5 min after both X and XT treatments; however, the XT combination produced a longer duration of sedation and analgesia than X alone. Two horses in the XT treatment group displayed excited transient behavior within 5 min of drug administration. The results suggest that the XT combination is useful for sedation and analgesia in horses. However, careful monitoring for excited behavior shortly after administration is recommended. PMID:21897102
The efficacy of the new SCD response compression system in the prevention of venous stasis.
Kakkos, S K; Szendro, G; Griffin, M; Daskalopoulou, S S; Nicolaides, A N
2000-11-01
The current commercially available sequential intermittent pneumatic compression device used for the prevention of deep venous thrombosis has a constant cycle of 11 seconds' compression and 60 seconds' deflation. This deflation period ensures that the veins are filled before the subsequent cycle begins. It has been suggested that in some positions (eg, semirecumbent or sitting) and with different patients (eg, those with venous reflux), refilling of the veins may occur much earlier than 60 seconds, and thus a more frequent cycle may be more effective in expelling blood proximally. The aim of the study was to test the effectiveness of a new sequential compression system (the SCD Response Compression System), which has the ability to detect the change in the venous volume and to respond by initiating the subsequent cycle when the veins are substantially full. In an open controlled trial at an academic vascular laboratory, the SCD Response Compression System was tested against the existing SCD Sequel Compression System in 12 healthy volunteers who were in supine, semirecumbent, and sitting positions. The refilling time sensed by the device was compared with that determined from recordings of femoral vein flow velocity by the use of duplex ultrasound scan. The total volume of blood expelled per hour during compression was compared with that produced by the existing SCD system in the same volunteers and positions. The refilling time determined automatically by the SCD Response Compression System varied from 24 to 60 seconds in the subjects tested, demonstrating individual patient variation. The refilling time (mean +/- SD) in the sitting position was 40.6 +/- 10. 0 seconds, which was significantly longer (P <.001) than that measured in the supine and semirecumbent positions, 33.8 +/- 4.1 and 35.6 +/- 4.9 seconds, respectively. There was a linear relationship between the duplex scan-derived refill time (mean of 6 readings per leg) and the SCD Response device-derived refill time (r = 0.85, P <. 001). The total volume of blood (mean +/- SD) expelled per hour by the existing SCD Sequel device in the supine, semirecumbent, and sitting positions was 2.23 +/- 0.90 L/h, 2.47 +/- 0.86 L/h, and 3.28 +/- 1.24 L/h, respectively. The SCD Response device increased the volume expelled to 3.92 +/- 1.60 L/h or a 76% increase (P =.001) in the supine position, to 3.93 +/- 1.55 L/h or a 59% increase (P =. 001) in the semirecumbent position, and to 3.97 +/- 1.42 L/h or a 21% increase (P =.026) in the sitting position. By achieving more appropriately timed compression cycles over time, the new SCD Response System is effective in preventing venous stasis by means of a new method that improves on the clinically documented effectiveness of the existing SCD system. Further studies testing its potential for improved efficacy in preventing deep venous thrombosis are justified.
Mayr, Stefan; Schmid, Peter; Laur, Joan; Rosner, Sabine; Charra-Vaskou, Katline; Dämon, Birgit; Hacke, Uwe G.
2014-01-01
Xylem embolism is a limiting factor for woody species worldwide. Conifers at the alpine timberline are exposed to drought and freeze-thaw stress during winter, which induce potentially lethal embolism. Previous studies indicated that timberline trees survive by xylem refilling. In this study on Picea abies, refilling was monitored during winter and spring seasons and analyzed in the laboratory and in situ experiments, based on hydraulic, anatomical, and histochemical methods. Refilling started in late winter, when the soil was frozen and soil water not available for the trees. Xylem embolism caused up to 86.2% ± 3.1% loss of conductivity and was correlated with the ratio of closed pits. Refilling of xylem as well as recovery in shoot conductance started in February and corresponded with starch accumulation in secondary phloem and in the mesophyll of needles, where we also observed increasing aquaporin densities in the phloem and endodermis. This indicates that active, cellular processes play a role for refilling even under winter conditions. As demonstrated by our experiments, water for refilling was thereby taken up via the branches, likely by foliar water uptake. Our results suggest that refilling is based on water shifts to embolized tracheids via intact xylem, phloem, and parenchyma, whereby aquaporins reduce resistances along the symplastic pathway and aspirated pits facilitate isolation of refilling tracheids. Refilling must be taken into account as a key process in plant hydraulics and in estimating future effects of climate change on forests and alpine tree ecosystems. PMID:24521876
Image RPI Reawakens Plasmaspheric Refilling Research
NASA Technical Reports Server (NTRS)
Gallagher, D. L.; Smith, Z. B.
2007-01-01
The plasmasphere is a toroidal region of cold plasma surrounding the Earth that results from ionospheric outflow and accumulation. The physics of refilling and the dynamics of this region have been studied for nearly 50-years. During that time many models have been proposed, but little has been done to test these models due to a lack of observational information. With the launch of the IMAGE Mission in March 2000 the Radio Plasma Imager has provided true field aligned density measurements that uniquely enable the testing of these models and a final determination of the physical processes important for the plasmasphere's recovery from storm-time conditions.
Self-Consistent Superthermal Electron Effects on Plasmaspheric Refilling
NASA Technical Reports Server (NTRS)
Liemohn, M. W.; Khazanov, G. V.; Moore, T. E.; Guiter, S. M.
1997-01-01
The effects of self-consistently including superthermal electrons in the definition of the ambipolar electric field are investigated for the case of plasmaspheric refilling after a geomagnetic storm. By using the total electron population in the hydrodynamic equations, a method for incorporating superthermal electron parameters in the electric field and electron temperature calculation is developed. Also, the ambipolar electric field is included in the kinetic equation for the superthermal electrons through a change of variables using the total energy and the first adiabatic invariant. Calculations based on these changes are performed by coupling time-dependent models of the thermal plasma and superthermal electrons. Results from this treatment of the electric field and the self-consistent development of the solution are discussed in detail. Specifically, there is a decreased thermal electron density in the plasmasphere during the first few minutes of refilling, a slightly accelerated proton shock front, and a decreased superthermal electron flux due to the deceleration by the electric field. The timescales of plasmaspheric refilling are discussed and determined to be somewhat shorter than previously calculated for the thermal plasma and superthermal electron population due to the effects of the field-aligned potential.
A semikinetic model for early stage plasmasphere refilling. I - Effects of Coulomb collisions
NASA Technical Reports Server (NTRS)
Wilson, G. R.; Horwitz, J. L.; Lin, J.
1992-01-01
A collisionless, time-dependent, kinetic plasma model is applied to the problem of baseline plasmasphere refilling of an initially depleted flux tube, without regard for the effects of wave-particle interactions. Refilling calculations for various flux tubes and for different ionospheric plasma fluxes and temperatures are performed. In each case considered, the same set of events occurs. Initially, two polar wind outflows develop from each hemisphere and set up counterstreaming beams. With time the vacant phase space region between these beams fills, primarily because of collision-induced particle diffusion but also because of lowering ambipolar potential drops from the increasing density in the plasmasphere. In contrast to all previous hydrodynamic approaches, no formation of shocks was found. The plasma first evolves an isotropic, nearly Maxwellian velocity distribution in a region that starts near the ionosphere and moves outward toward the equator. For reasonable topside ionospheric temperatures and fluxes, the thermal plasma all along an L shell is found to become nearly isotropic in 6 to 30 hr, consistent with the observations of Horwitz et al. (1984).
Cox, Jill; Kaes, Loretta; Martinez, Miguel; Moles, Daniel
2016-10-01
Skin temperature may help prospectively determine whether an area of skin discoloration will evolve into necrosis. A prospective, observational study was conducted in 7 skilled nursing facilities to determine if skin temperature measured using infrared thermography could predict the progression of discolored intact skin (blanchable erythema, Stage 1 pressure ulcer, or sus- pected deep tissue injury [sDTI]) to necrosis and to evaluate if nurses could effectively integrate thermography into the clinical setting. Patients residing in or presenting to the facility between October 2014 and August 2015 with a pressure-related area of discolored skin determined to be blanchable erythema, a Stage 1 pressure ulcer, or sDTI and anticipated length of stay >6 days were assessed at initial presentation of the discolored area and after 7 and 14 days by facility nurses trained on camera operation and study protocol. Variables included patient demographic and clinical data, data related to the discolored area (eg, size, date of initial discovery), and temperature and appearance differences between discolored and adjacent intact skin. Skin temperatures at the discolored and adjacent areas were measured during the initial assessment. All facility pressure ulcer prevention and treatment protocols derived from evidence-based clinical practice guidelines remained in use during the study time period. Participating nurses completed a 2-part, pencil/paper survey to examine the feasibility of incorporating thermography for skin assessment into practice. Data analyses were performed using descriptive statistics (frequency analyses) and bivariate analysis (t-tests and chi-squared tests); logistic regression was used to assess associations among patient and pressure ulcer variables. Of the 67 patients studied, the overall mean age was 85 years (SD 10); 52 were women; 63 were Caucasian; and the top 3 diagnoses, accounting for 60% of the study sample, included neurologic (ie, cardiovascular acci- dent/dementia [14, 21%]), cardiac-related (14, 21%), and orthopedic (13, 19%) conditions. Twenty-eight (28) participants were long-term care patients, and 39 were admitted as short-stay patients. The most frequently reported location of discolored intact skin on presentation was the heel (27, 40%). The mean temperature at the site of the discolored skin was 33.6 ̊ C (SD 3) and at the adjacent skin was 33.5 ̊ C (SD 2.5). The mean size of the areas of discoloration was 11 cm2 (SD 21). Capillary refill of the discolored area was absent on initial presentation in 49 patients (72%), and demarcation of the discolored borders was evident for 45 (66%). Of the 67 patients, 30 (45%) experienced complete resolution of the discolored area. At day 7, 8 (16%) of the remaining 50 patients in the sample exhibited skin necrosis and at day 14, a total of 12 patients of the remaining 37 (32%) exhibited skin necrosis. At day 7, skin necrosis was significantly associated with admission to a subacute unit (P = 0.01) and at day 14 to negative capillary refill at initial presentation (P = 0.02). Regardless of skin temperature, negative capillary refill at presentation was significantly associated with skin necrosis at day 7 (P = 0.04). A dichotomous variable was constructed to examine patients with cooler temperatures at the site as compared to their adjacent skin and persons with warmer skin temperatures at the center of the discolored skin for the presence of skin necrosis at both day 7 and day 14. In multivariate analysis, patients with cooler rather than warmer skin temperatures at the center of the discolored area as compared to the adjacent skin were more likely to develop necrosis by day 7 (OR 18.8; P = 0.05; CI: 104-342.44). Participating nurses were uncertain about the feasibility of integrating thermography into practice. Larger prospective studies with more heterogeneous samples are needed to determine the validity of skin temperature measurement as a predictor of skin necrosis and the utility of implementing thermography into clinical practice.
Pfeiffer, James T; Napúa, Manuel; Wagenaar, Bradley H; Chale, Falume; Hoek, Roxanne; Micek, Mark; Manuel, João; Michel, Cathy; Cowan, Jessica Greenberg; Cowan, James F; Gimbel, Sarah; Sherr, Kenneth; Gloyd, Stephen; Chapman, Rachel R
2017-11-01
This randomized trial studied performance of Option B+ in Mozambique and evaluated an enhanced retention package in public clinics. The study was conducted at 6 clinics in Manica and Sofala Provinces in central Mozambique. Seven hundred sixty-one pregnant women tested HIV+, immediately initiated antiretroviral (ARV) therapy, and were followed to track retention at 6 clinics from May 2014 to May 2015. Clinics were randomly allocated within a stepped-wedge fashion to intervention and control periods. The intervention included (1) workflow modifications and (2) active patient tracking. Retention was defined as percentage of patients returning for 30-, 60-, and 90-day medication refills within 25-35 days of previous refills. During control periods, 52.3% of women returned for 30-day refills vs. 70.8% in intervention periods [odds ratio (OR): 1.80; 95% confidence interval (CI): 1.05 to 3.08]. At 60 days, 46.1% control vs. 57.9% intervention were retained (OR: 1.82; CI: 1.06 to 3.11), and at 90 days, 38.3% control vs. 41.0% intervention (OR: 1.04; CI: 0.60 to 1.82). In prespecified subanalyses, birth before pickups was strongly associated with failure-women giving birth before ARV pickup were 33.3 times (CI: 4.4 to 250.3), 7.5 times (CI: 3.6 to 15.9), and 3.7 times (CI: 2.2 to 6.0) as likely to not return for ARV pickups at 30, 60, and 90 days, respectively. The intervention was effective at 30 and 60 days, but not at 90 days. Combined 90-day retention (40%) and adherence (22.5%) were low. Efforts to improve retention are particularly important for women giving birth before ARV refills.
Improving medication adherence with a targeted, technology-driven disease management intervention.
Lawrence, David B; Allison, Wanda; Chen, Joyce C; Demand, Michael
2008-06-01
Treatment adherence is critical in managing chronic disease, but achieving it remains an elusive goal across many prevalent conditions. As part of its care management strategy, BlueCross BlueShield of South Carolina (BCBSSC) implemented the Longitudinal Adherence Treatment Evaluation program, a behavioral intervention to improve medication adherence among members with cardiovascular disease and/or diabetes. The objectives of this study were to 1) assess the effectiveness of telephonic intervention in influencing reinitiation of medication therapy, and 2) evaluate the rate and timing of medication reinitiation. BCBSSC applied algorithms against pharmacy claims data to identify patients prescribed targeted medications who were 60 or more days overdue for refills. This information was provided to care managers to address during their next patient contact. Care managers received focused training on techniques for medication behavior change, readiness to change, motivational interviewing, and active listening. Training also addressed common barriers to adherence and available resources, including side effect management, mail order benefits, drug assistance programs, medication organizers, and reminder systems. Overdue refills were tracked for 12 months, with medication reinitiation followed for an additional 3 months. In the intervention group, 94 patients were identified with 123 instances of late medication refills. In the age- and gender-matched comparison group, 61 patients were identified with 76 late refills. The intervention group had a significantly higher rate of medication reinitiation (59.3%) than the control group (42.1%; P < 0.05). Time to reinitiation was significantly shorter in the intervention group, 59.5 (+/- 69.0) days vs. 107.4 (+/- 109) days for the control group (P < 0.05). This initiative demonstrated that a targeted disease management intervention promoting patient behavior change increased the number of patients who reinitiated therapy after a period of nonadherence and decreased the time from nonadherence to adherence.
Visser, Cobus; Kieser, Eduard; Dellimore, Kiran; van den Heever, Dawie; Smith, Johan
2017-10-01
This study explores the feasibility of prospectively assessing infant dehydration using four non-invasive, optical sensors based on the quantitative and objective measurement of various clinical markers of dehydration. The sensors were investigated to objectively and unobtrusively assess the hydration state of an infant based on the quantification of capillary refill time (CRT), skin recoil time (SRT), skin temperature profile (STP) and skin tissue hydration by means of infrared spectrometry (ISP). To evaluate the performance of the sensors a clinical study was conducted on a cohort of 10 infants (aged 6-36 months) with acute gastroenteritis. High sensitivity and specificity were exhibited by the sensors, in particular the STP and SRT sensors, when combined into a fusion regression model (sensitivity: 0.90, specificity: 0.78). The SRT and STP sensors and the fusion model all outperformed the commonly used "gold standard" clinical dehydration scales including the Gorelick scale (sensitivity: 0.56, specificity: 0.56), CDS scale (sensitivity: 1.0, specificity: 0.2) and WHO scale (sensitivity: 0.13, specificity: 0.79). These results suggest that objective and quantitative assessment of infant dehydration may be possible using the sensors investigated. However, further evaluation of the sensors on a larger sample population is needed before deploying them in a clinical setting. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Sync and swim: the impact of medication consolidation on adherence in Medicaid patients.
Ross, Alexander; Jami, Humaira; Young, Heather A; Katz, Richard
2013-10-01
Medication nonadherence is associated with higher cost of care and poor outcomes. Medication refill consolidation (synchronization of refill dates for patients on multiple drugs) is an important component of regimen complexity. We presumed that Medicaid patients with a 30-day medication supply limit would have significant difficulty with refill consolidation. We evaluated regimen complexity and refill consolidation in relation to medication adherence in the Medicaid population. A survey was administered to 50 Medicaid patients taking 2 or more daily medications in the outpatient setting. The survey included demographics, 13 items related to medication and pharmacy history, and 10 items related to medication regimen complexity and refill consolidation. Chi-square analysis was used to assess the relationship between adherence and missed medication doses due to regimen complexity. Wilcoxon rank sum test was used to determine association between total number of prescribing providers and number of daily medications with various aspects of regimen complexity. 52% were required to go to the pharmacy more than once per month to keep all of their medications filled and 46% missed a day or more of medication because their medications must be refilled on different dates. Those who missed a day or more of medication because of need to refill prescriptions on different days had higher number of prescriptions (P = .03) and higher number of prescribers (P = .03). Medicaid patients had low medication adherence in the context of high regimen complexity and poor refill consolidation. This population would benefit from interventions focused on improving synchronization of medication refills.
Patients at Risk: Large Opioid Prescriptions After Total Knee Arthroplasty.
Hernandez, Nicholas M; Parry, Joshua A; Taunton, Michael J
2017-08-01
Opioids are an effective, and often necessary, treatment of postoperative pain after total knee arthroplasty (TKA). However, it is often difficult to know how much medication patients will need after discharge. The purpose of this study was to determine if patients discharged with greater quantities of opioids after TKA are more likely to request refills. This is a retrospective review of 105 primary TKAs performed with at least 1 year of follow-up. Exclusion criteria included bilateral TKA, preoperative opioid use, or reoperation within the first 3 months. Data collected included opioid refills, Knee Society Score, and total and daily morphine equivalent dose (MED) prescribed. Patients were most commonly discharged on oxycodone (90%), hydromorphone (5%), and hydrocodone/acetaminophen (1%). The average total prescribed MED was 1405 ± 616 mg (range, 273-3250 mg). Patients requiring refills did not differ in the total prescribed MED (1521 ± 624 vs 1349 ± 609 mg; P = .1), daily prescribed MED (153 ± 10 vs 155 ± 7 mg; P = .8), or preoperative Knee Society Score (63 ± 16 vs 60 ± 13; P = .3). Average follow-up time was 2.4 ± 0.5 years. The quantity of opioids prescribed after TKA varied widely, ranging from a total MED of 273-3250 mg. The refill rate did not differ between large prescriptions (≥1400 mg) and smaller prescriptions. Excessive opioid prescriptions should be avoided as they did not decrease the number of refills and pose the risk of divergence and subsequent abuse. Copyright © 2017 Elsevier Inc. All rights reserved.
Erosion and refilling of the plasmasphere during a geomagnetic storm modeled by a neural network
NASA Astrophysics Data System (ADS)
Chu, X. N.; Bortnik, J.; Li, W.; Ma, Q.; Angelopoulos, V.; Thorne, R. M.
2017-07-01
We present a history-dependent model of the equatorial plasma density of the inner magnetosphere using a feedforward neural network with two hidden layers. As the model inputs, we take locations and time series of SYM-H, AL, and F10.7 indices. By considering not only the instantaneous values but also the past values of geomagnetic and solar indices, the model is history dependent on levels of geomagnetic and solar activity. The modeled electron density is continuous both spatially and temporally so that the evolution of the density can be studied (such as plasmaspheric refilling). The model is trained using the electron density inferred from the spacecraft potential from three THEMIS probes. The equatorial electron density is shown to be accurately reconstructed with a correlation coefficient of r 0.953 between data and model target. Since the model is history dependent, it succeeds in reconstructing various density features and dynamic behaviors, such as the quiet time plasmasphere, erosion and recovery of the plasmasphere, as well as the plume formation during a storm on 4 February 2011. Our model may provide unprecedented insight into the behavior of the equatorial density at any time and location; as an example we show the inferred refilling rate from our model and compare it to previous estimates.
40 CFR 165.45 - Refillable container standards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... PESTICIDE MANAGEMENT AND DISPOSAL Refillable Container Standards: Container Design § 165.45 Refillable... pesticide container must be capable of withstanding all operating stresses, taking into account static heat, pressure buildup from pumps and compressors, and any other foreseeable mechanical stresses to which the...
40 CFR 165.45 - Refillable container standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... PESTICIDE MANAGEMENT AND DISPOSAL Refillable Container Standards: Container Design § 165.45 Refillable... pesticide container must be capable of withstanding all operating stresses, taking into account static heat, pressure buildup from pumps and compressors, and any other foreseeable mechanical stresses to which the...
40 CFR 165.45 - Refillable container standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... PESTICIDE MANAGEMENT AND DISPOSAL Refillable Container Standards: Container Design § 165.45 Refillable... pesticide container must be capable of withstanding all operating stresses, taking into account static heat, pressure buildup from pumps and compressors, and any other foreseeable mechanical stresses to which the...
Code of Federal Regulations, 2013 CFR
2013-07-01
... repackaging of agricultural pesticides performed by refilling establishments subcategory. 455.60 Section 455... STANDARDS (CONTINUED) PESTICIDE CHEMICALS Repackaging of Agricultural Pesticides Performed at Refilling Establishments § 455.60 Applicability; description of repackaging of agricultural pesticides performed by...
Code of Federal Regulations, 2012 CFR
2012-07-01
... repackaging of agricultural pesticides performed by refilling establishments subcategory. 455.60 Section 455... STANDARDS (CONTINUED) PESTICIDE CHEMICALS Repackaging of Agricultural Pesticides Performed at Refilling Establishments § 455.60 Applicability; description of repackaging of agricultural pesticides performed by...
Code of Federal Regulations, 2014 CFR
2014-07-01
... repackaging of agricultural pesticides performed by refilling establishments subcategory. 455.60 Section 455... STANDARDS (CONTINUED) PESTICIDE CHEMICALS Repackaging of Agricultural Pesticides Performed at Refilling Establishments § 455.60 Applicability; description of repackaging of agricultural pesticides performed by...
Kamilari, Eleni; Farsalinos, Konstantinos; Poulas, Konstantinos; Kontoyannis, Christos G; Orkoula, Malvina G
2018-06-01
Electronic cigarettes are considered healthier alternatives to conventional cigarettes containing tobacco. They produce vapor through heating of the refill liquids (e-liquids) which consist of propylene glycol, vegetable glycerin, nicotine (in various concentrations), water and flavoring agents. Heavy metals may enter the refill liquid during the production, posing a risk for consumer's health due to their toxicity. The objective of the present study was the development of a methodology for the detection and quantitative analysis of cadmium (Cd), lead (Pb), nickel (Ni), copper (Cu), arsenic (As) and chromium (Cr), employing Total Reflection X-Ray Fluorescence Spectroscopy (TXRF) as an alternative technique to ICP-MS or ICP-OES commonly used for this type of analysis. TXRF was chosen due to its advantages, which include short analysis time, promptness, simultaneous multi-element analysis capability and minimum sample preparation, low purchase and operational cost. The proposed methodology was applied to a large number of electronic cigarette liquids commercially available, as well as their constituents, in order to evaluate their safety. TXRF may be a valuable tool for probing heavy metals in electronic cigarette refill liquids to serve for the protection of human health. Copyright © 2018 Elsevier Ltd. All rights reserved.
Adetunji, Adedotun A; Muyibi, Sufiyan A; Imhansoloeva, Martins; Ibraheem, Olusola M; Sunmola, Adegbenga; Kolawole, Olubunmi O; Akinrinsola, Oluwasina O; Ojo-Osagie, James O; Mosuro, Olusola A; Abiolu, Josephine O; Irabor, Achiaka E; Okonkwo, Prosper; Adewole, Isaac F; Taiwo, Babafemi O
2017-05-01
In sub-Saharan African areas where antiretroviral (ARV) drugs are not available through community pharmacies, clinic-based pharmacies are often the primary source of ARV drug refills. Social pressure is mounting on treatment providers to adjust ARV refill services towards user-friendly approaches which prioritize patients' convenience and engage their resourcefulness. By this demand, patients may be signalling dissatisfaction with the current provider-led model of monthly visits to facility-based pharmacies for ARV refill. Mobile phones are increasingly popular in sub-Saharan Africa, and have been used to support ARV treatment goals in this setting. A patient-centred response to on-going social pressure requires treatment providers to view ARV refill activities through the eyes of patients who are negotiating the challenges of day-to-day life while contemplating their next refill appointment. Using focus groups of five categories of adult patients receiving combination ARV therapy, we conducted this cross-sectional qualitative study to provide insight into modifiable gaps between patients' expectations and experiences of the use of mobile phones in facility-based ARV refill service at a public HIV clinic in Nigeria. A notable finding was patients' preference for harnessing informal social support (through intermediaries with mobile phones) to maintain adherence to ARV refill appointments when they could not present in person. This evolving social support strategy also has the potential to enhance defaulter tracking. Our study findings may inform the development of ARV refill strategies and the design of future qualitative studies on client-provider communication by mobile phones in under-resourced HIV treatment programmes.
49 CFR 178.71 - Specifications for UN pressure receptacles.
Code of Federal Regulations, 2013 CFR
2013-10-01
... this subchapter). (g) Design and construction requirements for UN refillable seamless steel cylinders. In addition to the general requirements of this section, UN refillable seamless steel cylinders must...—Refillable seamless steel gas cylinders—Design, construction and testing—Part 2: Quenched and tempered steel...
49 CFR 178.71 - Specifications for UN pressure receptacles.
Code of Federal Regulations, 2012 CFR
2012-10-01
... seamless steel cylinders. In addition to the general requirements of this section, UN refillable seamless... cylinders—Refillable seamless steel gas cylinders—Design, construction and testing—Part 1: Quenched and...). (2) ISO 9809-2: Gas cylinders—Refillable seamless steel gas cylinders—Design, construction and...
49 CFR 178.71 - Specifications for UN pressure receptacles.
Code of Federal Regulations, 2014 CFR
2014-10-01
... this subchapter). (g) Design and construction requirements for UN refillable seamless steel cylinders. In addition to the general requirements of this section, UN refillable seamless steel cylinders must...—Refillable seamless steel gas cylinders—Design, construction and testing—Part 2: Quenched and tempered steel...
49 CFR 178.71 - Specifications for UN pressure receptacles.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) [Reserved] (g) Design and construction requirements for UN refillable seamless steel cylinders. In addition to the general requirements of this section, UN refillable seamless steel cylinders must conform to the following ISO standards, as applicable: (1) ISO 9809-1: Gas cylinders—Refillable seamless steel...
49 CFR 178.71 - Specifications for UN pressure receptacles.
Code of Federal Regulations, 2011 CFR
2011-10-01
... seamless steel cylinders. In addition to the general requirements of this section, UN refillable seamless... cylinders—Refillable seamless steel gas cylinders—Design, construction and testing—Part 1: Quenched and...). (2) ISO 9809-2: Gas cylinders—Refillable seamless steel gas cylinders—Design, construction and...
40 CFR 165.65 - Registrants who distribute or sell pesticide products in refillable containers.
Code of Federal Regulations, 2011 CFR
2011-07-01
... pesticide products in refillable containers. 165.65 Section 165.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS PESTICIDE MANAGEMENT AND DISPOSAL Standards for Repackaging Pesticide Products into Refillable Containers § 165.65 Registrants who distribute or sell pesticide products...
40 CFR 165.65 - Registrants who distribute or sell pesticide products in refillable containers.
Code of Federal Regulations, 2013 CFR
2013-07-01
... pesticide products in refillable containers. 165.65 Section 165.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS PESTICIDE MANAGEMENT AND DISPOSAL Standards for Repackaging Pesticide Products into Refillable Containers § 165.65 Registrants who distribute or sell pesticide products...
40 CFR 165.67 - Registrants who distribute or sell pesticide products to refillers for repackaging.
Code of Federal Regulations, 2013 CFR
2013-07-01
... pesticide products to refillers for repackaging. 165.67 Section 165.67 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS PESTICIDE MANAGEMENT AND DISPOSAL Standards for Repackaging Pesticide Products into Refillable Containers § 165.67 Registrants who distribute or sell...
40 CFR 165.65 - Registrants who distribute or sell pesticide products in refillable containers.
Code of Federal Regulations, 2014 CFR
2014-07-01
... pesticide products in refillable containers. 165.65 Section 165.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS PESTICIDE MANAGEMENT AND DISPOSAL Standards for Repackaging Pesticide Products into Refillable Containers § 165.65 Registrants who distribute or sell pesticide products...
40 CFR 165.65 - Registrants who distribute or sell pesticide products in refillable containers.
Code of Federal Regulations, 2012 CFR
2012-07-01
... pesticide products in refillable containers. 165.65 Section 165.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS PESTICIDE MANAGEMENT AND DISPOSAL Standards for Repackaging Pesticide Products into Refillable Containers § 165.65 Registrants who distribute or sell pesticide products...
40 CFR 165.67 - Registrants who distribute or sell pesticide products to refillers for repackaging.
Code of Federal Regulations, 2012 CFR
2012-07-01
... pesticide products to refillers for repackaging. 165.67 Section 165.67 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS PESTICIDE MANAGEMENT AND DISPOSAL Standards for Repackaging Pesticide Products into Refillable Containers § 165.67 Registrants who distribute or sell...
40 CFR 165.67 - Registrants who distribute or sell pesticide products to refillers for repackaging.
Code of Federal Regulations, 2011 CFR
2011-07-01
... pesticide products to refillers for repackaging. 165.67 Section 165.67 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS PESTICIDE MANAGEMENT AND DISPOSAL Standards for Repackaging Pesticide Products into Refillable Containers § 165.67 Registrants who distribute or sell...
Physical signs of dehydration in the elderly.
Shimizu, Miyuki; Kinoshita, Kensuke; Hattori, Kazuya; Ota, Yoshio; Kanai, Takao; Kobayashi, Hiroyuki; Tokuda, Yasuharu
2012-01-01
Dehydration is a common condition and frequent cause of hospitalization in older people, despite the caregiver's high attention in attempt to avoid its occurrence. In this study, various physical signs were examined as clinical signs of dehydration in elderly. A prospective observational study was conducted in an acute care teaching hospital. Consecutive elderly patients who were admitted to the Department of Medicine were evaluated. Dehydration was defined as a calculated serum osmolality above 295 mOsm/L. The patients diagnosed as dehydrated or not dehydrated were observed for physical signs of dehydration. Data of blood and urine chemistry analysis were also compared between the two groups. A total of 27 elderly patients admitted with acute medical conditions were included in this study. For the physical signs, dry axilla had moderate sensitivity (44%) and excellent specificity (89%) to detect dehydration. Sunken eyes and delayed capillary refill time also showed relatively good specificity (83%). For laboratory data, the mean concentrations of serum sodium of the dehydrated group (146 mEq/L) was significantly higher (p<0.01) than those of the non-dehydrated group (134 mEq/L). Physical signs of dehydration in elderly showed relatively good specificity but poor sensitivity. The evaluation of the axillary moisture could help assess dehydration as well as laboratory data analysis such as serum sodium concentration.
Mousa, Albeir Y; Abu-Halimah, Shadi; Alhalbouni, Saadi; Hass, Stephen M; Yang, Calvin; Gill, Gurpreet; AbuRahma, Ali F; Bates, Mark
2014-10-01
Hepatic hemorrhage can be devastating, especially in patients with underlying hepatic pathology. This is a case report of a 50-year-old man who presented to the emergency room with Stage 3 shock as evidenced by a systolic blood pressure of 90 mmHg, a heart rate of 125 beats per minute, respiration of 32, with delayed capillary refill and agitation. At this time, he was found to have a massive spontaneous intra-abdominal hemorrhage with an advanced stage of amyloidosis with multiple organ malfunctions. The initial diagnosis was based on an abdominal computed tomography scan and the patient was taken expeditiously to a hybrid angiography suite for a celiac angiogram. An intraoperative diagnosis of extravasation from amyloid related vasculopathy was made based on the angiographic appearance of hepatic circulation. Coil embolization of the feeding branch of the bleeder was achieved using the interlock coil system and a completion angiogram was done showing complete cessation of active bleeding. The postoperative phase was uneventful and the patient was discharged home on postoperative day three. His postoperative visit at five months later was unremarkable. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Airflow obstruction among street vendors who refill cigarette lighters with liquefied petroleum gas.
Moitra, S; Blanc, P D; Brashier, B B
2014-09-01
Manual cigarette lighter refilling with butane/propane admixed liquefied petroleum gas (LPG) is a common low-income occupation in India. This practice may cause adverse health effects from LPG exposure among such workers. To assess respiratory status among LPG-exposed workers and non-exposed controls. We quantified the exposure and evaluated respiratory symptoms and lung function among 113 LPG refilling workers (aged 41.9±9.9 years) and 79 controls (aged 40.8±7.2 years). We used multiple linear regression analysis to estimate the LPG exposure response within the group of refilling workers, adjusting for age, height and smoking status. Compared to the controls, the LPG-exposed lighter refillers manifested a 190 ml decrement in 1-second forced expiratory volume (FEV1) (2.55±0.4 vs. 2.26±0.3 l) and a 6% decrement in FEV1/forced vital capacity (FVC) (both P < 0.05). We found a significantly negative exposure response among the LPG workers: for FVC and FEV1, 44 ml per ml of reported daily LPG use in refilling (P < 0.05). Likely heavy exposure to LPG through manually refilling cigarette lighters is associated with airflow decrements. This adverse effect may be relevant to other occupational groups heavily exposed to volatile hydrocarbons, especially those in marginal employment sectors.
Factors that influence patient response to requests to change to a unified restrictive formulary.
Smetana, Gerald W; Davis, Roger B; Phillips, Russell S
2004-12-01
To determine factors that influence patient willingness to accept a medication change to a unified, restrictive formulary. Prospective cohort study. University-affiliated hospital-based primary care internal medicine practice. Two hundred ninety-seven members of a managed care plan who had received a prescription for a nonformulary medication in the previous 4 months and whose primary care physician approved a conversion to a formulary medication. Clinical nurses invited patients to change to a formulary medication at the time of a telephone refill request based on a standard script. The overall conversion rate to the formulary medication was 59.8%. Seventy-four percent of patients who requested a refill by telephone converted to the formulary (odds ratio [OR], 2.24; 95% confidence interval [CI], 1.02 to 4.72). Patient age (OR, 1.03; CI, 1.01 to 1.05) and male gender (OR, 2.00; CI, 1.09 to 3.67) were each significant correlates of conversion. After adjustment in a multivariable model, only telephone refill request (adjusted OR, 2.31; CI, 1.07 to 4.97) and age (adjusted OR, 1.03; CI, 1.01 to 1.06) remained significant. Among the patients who made a telephone refill request, those who converted were more likely to completely trust their physician's judgment (P=.04) and to trust their physician to put their health over cost concerns (P=.05). Formulary conversion reduced costs beginning 3 months after the conversion date. A protocol for encouraging conversion to a unified formulary at the point of a telephone refill request increases formulary compliance rates and reduces medication costs. Patients who decline to convert medications are less likely to trust their physician.
40 CFR 165.67 - Registrants who distribute or sell pesticide products to refillers for repackaging.
Code of Federal Regulations, 2014 CFR
2014-07-01
... writing. (1) You must develop a refilling residue removal procedure that describes how to remove pesticide... procedure for the pesticide product. (2) Your written description of acceptable containers for the pesticide... containers. (2) Your written refilling residue removal procedure for the pesticide product. (3) Your written...
The endoplasmic reticulum, not the pH gradient, drives calcium refilling of lysosomes
Garrity, Abigail G; Wang, Wuyang; Collier, Crystal MD; Levey, Sara A; Gao, Qiong; Xu, Haoxing
2016-01-01
Impaired homeostasis of lysosomal Ca2+ causes lysosome dysfunction and lysosomal storage diseases (LSDs), but the mechanisms by which lysosomes acquire and refill Ca2+ are not known. We developed a physiological assay to monitor lysosomal Ca2+ store refilling using specific activators of lysosomal Ca2+ channels to repeatedly induce lysosomal Ca2+ release. In contrast to the prevailing view that lysosomal acidification drives Ca2+ into the lysosome, inhibiting the V-ATPase H+ pump did not prevent Ca2+ refilling. Instead, pharmacological depletion or chelation of Endoplasmic Reticulum (ER) Ca2+ prevented lysosomal Ca2+ stores from refilling. More specifically, antagonists of ER IP3 receptors (IP3Rs) rapidly and completely blocked Ca2+ refilling of lysosomes, but not in cells lacking IP3Rs. Furthermore, reducing ER Ca2+ or blocking IP3Rs caused a dramatic LSD-like lysosome storage phenotype. By closely apposing each other, the ER may serve as a direct and primary source of Ca2+for the lysosome. DOI: http://dx.doi.org/10.7554/eLife.15887.001 PMID:27213518
Refilling of carbon nanotube cartridges for 3D nanomanufacturing
NASA Astrophysics Data System (ADS)
Bekarevich, Raman; Toyoda, Masami; Baba, Shuichi; Nakata, Toshihiko; Hirahara, Kaori
2016-03-01
Metal-filled carbon nanotubes (CNTs) are known to be used as pen-tip injectors for 3D manufacturing on the nanoscale. However, the CNT interior cannot accumulate enough material to fabricate complex metallic nanostructures. Therefore a method for refilling the CNT cartridge needs to be developed. The strategy for refilling of CNT cartridges is suggested in this study. Controlled growth of gold nanowires in the interior of isolated CNTs using a real-time manipulator installed in a transmission electron microscope is reported herein. The encapsulation process of discrete gold nanoparticles in the hollow spaces of open-ended multi-wall CNTs was evaluated in detail. The experimental results reveal that the serial loading of isolated gold nanoparticles allows the control of the length of the loaded nanowires with nanometer accuracy. Thermophoresis and the coalescence of gold nanoparticles are assumed to be the primary mechanisms responsible for gold loading into a CNT cartridge.Metal-filled carbon nanotubes (CNTs) are known to be used as pen-tip injectors for 3D manufacturing on the nanoscale. However, the CNT interior cannot accumulate enough material to fabricate complex metallic nanostructures. Therefore a method for refilling the CNT cartridge needs to be developed. The strategy for refilling of CNT cartridges is suggested in this study. Controlled growth of gold nanowires in the interior of isolated CNTs using a real-time manipulator installed in a transmission electron microscope is reported herein. The encapsulation process of discrete gold nanoparticles in the hollow spaces of open-ended multi-wall CNTs was evaluated in detail. The experimental results reveal that the serial loading of isolated gold nanoparticles allows the control of the length of the loaded nanowires with nanometer accuracy. Thermophoresis and the coalescence of gold nanoparticles are assumed to be the primary mechanisms responsible for gold loading into a CNT cartridge. Electronic supplementary information (ESI) available: Variations of loading of the initial nanoparticle into the CNT, movies demonstrating the processes of the loading of the initial nanoparticle and elongation of encapsulated nanowire. See DOI: 10.1039/c5nr08712k
Transdermal nicotine absorption handling e-cigarette refill liquids.
Maina, Giovanni; Castagnoli, Carlotta; Passini, Valter; Crosera, Matteo; Adami, Gianpiero; Mauro, Marcella; Filon, Francesca Larese
2016-02-01
The concentrated nicotine in e-cigarette refill liquids can be toxic if inadvertently ingested or absorbed through the skin. Reports of poisonings due to accidental ingestion of nicotine on refill liquids are rapidly increasing, while the evaluation of nicotine dermally absorbed still lacks. For that reason we studied transdermal nicotine absorption after the skin contamination with e-liquid. Donor chambers of eight Franz diffusion cells were filled with 1 mL of 0.8 mg/mL nicotine e-liquid for 24 h. The concentration of nicotine in the receiving phase was determined by high-performance liquid chromatography (LOD:0.1 μg/mL). Nicotine was detectable in receiving solution 2 h after the start of exposure and increased progressively. The medium flux calculated was 4.82 ± 1.05 μg/cm(2)/h with a lag time of 3.9 ± 0.1 h. After 24 h, the nicotine concentration in the receiving compartment was 101.02 ± 22.35 μg/cm(2) corresponding to 3.04 mg of absorbed nicotine after contamination of a skin surface of 100 cm(2). Skin contamination with e-liquid can cause nicotine skin absorption: caution must be paid when handling refill e-liquids. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Lemon, C.; Bishop, R. L.; Coster, A. J.; Nikoukar, R.; Chen, M.; Turner, D. L.; Roeder, J. L.; Shumko, M.; Payne, C.; Bhatt, R.
2017-12-01
Magnetosphere-ionosphere coupling is a complex process, and researchers must consider a number of factors: particle transport in the electric and magnetic fields drives plasma from the high latitude tail to the mid-latitude inner magnetosphere; particle precipitation into the ionosphere, which is frequently driven by wave-particle interactions, enhances the ionospheric conductivities; feedback of the ionospheric conductivities on the electric fields determines how well the convection electric field penetrates to the mid-latitude ionosphere; and the erosion and refilling of cold plasma in the plasmasphere substantially determines the mass of plasma on magnetospheric field lines and the subsequent wave environment that drives particle precipitation. While we model all of these processes, in this presentation we focus on the role of the plasmasphere and its role in M-I coupling. We present RCM-E simulations in which particle transport through self-consistent fields controls the drainage of the plasmasphere, an outflow model determines the plasmasphere refilling rate, and electron and ion precipitation influences the electric field by enhancing the ionospheric conductivity. The plasmasphere significantly affects the spatial structure of the wave environment and electron precipitation rates. This impacts the dynamics of the sub-auroral polarization stream (SAPS) in the pre-midnight region equatorward of the auroral boundary, which itself drives erosion of the plasmasphere through strong westward electric fields near the plasmapause. We present comparisons with Van Allen Probes, THEMIS, the Plasmasphere Data Assimilation (PDA) model, and line-of-sight observations from Millstone Hill ISR and space-based GPS receivers, showing how our modeled plasmasphere compares with observational data during the 17-March-2013 and 28-June-2013 magnetic storms. To better understand refilling, we focus particular attention on densities in the recently-depleted flux tubes in the plasmasphere trough. We compare several empirical models of the plasmasphere refilling rate to see which ones give the best agreement, and through parametric simulations we systematically investigate the effect of varying the local time and L dependence of the refilling rate.
27 CFR 70.149 - Refiling of notice of tax lien.
Code of Federal Regulations, 2014 CFR
2014-04-01
... effectiveness of the notice with respect to: (i) Property which is the subject matter of a suit, to which the.... However, if a suit or levy referred to in the preceding sentence is dismissed or released, respectively... effective after the suit or levy is dismissed or released unless refiled during the required refiling period...
27 CFR 70.149 - Refiling of notice of tax lien.
Code of Federal Regulations, 2012 CFR
2012-04-01
... effectiveness of the notice with respect to: (i) Property which is the subject matter of a suit, to which the.... However, if a suit or levy referred to in the preceding sentence is dismissed or released, respectively... effective after the suit or levy is dismissed or released unless refiled during the required refiling period...
27 CFR 70.149 - Refiling of notice of tax lien.
Code of Federal Regulations, 2011 CFR
2011-04-01
... effectiveness of the notice with respect to: (i) Property which is the subject matter of a suit, to which the.... However, if a suit or levy referred to in the preceding sentence is dismissed or released, respectively... effective after the suit or levy is dismissed or released unless refiled during the required refiling period...
27 CFR 70.149 - Refiling of notice of tax lien.
Code of Federal Regulations, 2013 CFR
2013-04-01
... effectiveness of the notice with respect to: (i) Property which is the subject matter of a suit, to which the.... However, if a suit or levy referred to in the preceding sentence is dismissed or released, respectively... effective after the suit or levy is dismissed or released unless refiled during the required refiling period...
Gazmararian, Julie A; Kripalani, Sunil; Miller, Michael J; Echt, Katharina V; Ren, Junling; Rask, Kimberly
2006-01-01
BACKGROUND The factors influencing medication adherence have not been fully elucidated. Inadequate health literacy skills may impair comprehension of medical care instructions, and thereby reduce medication adherence. OBJECTIVES To examine the relationship between health literacy and medication refill adherence among Medicare managed care enrollees with cardiovascular-related conditions. RESEARCH DESIGN Prospective cohort study. SUBJECTS New Medicare enrollees from 4 managed care plans who completed an in-person survey and were identified through administrative data as having coronary heart disease, hypertension, diabetes mellitus, and/or hyperlipidemia (n=1,549). MEASURES Health literacy was determined using the short form of the Test of Functional Health Literacy in Adults (S-TOFHLA). Prospective administrative data were used to calculate the cumulative medication gap (CMG), a valid measure of medication refill adherence, over a 1-year period. Low adherence was defined as CMG≥20%. RESULTS Overall, 40% of the enrollees had low refill adherence. Bivariate analyses indicated that health literacy, race/ethnicity, education, and regimen complexity were each related to medication refill adherence (P<.05). In unadjusted analysis, those with inadequate health literacy skills had increased odds (odds ratio [OR]=1.37, 95% confidence interval [CI]: 1.08 to 1.74) of low refill adherence compared with those with adequate health literacy skills. However, the OR for inadequate health literacy and low refill adherence was not statistically significant in multivariate analyses (OR=1.23, 95% CI: 0.92 to 1.64). CONCLUSIONS The present study suggests, but did not conclusively demonstrate, that low health literacy predicts poor refill adherence. Given the prevalence of both conditions, future research should continue to examine this important potential association. PMID:17105519
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stansfield, S.; Shawver, D.; Sobel, A.
This paper presents a prototype virtual reality (VR) system for training medical first responders. The initial application is to battlefield medicine and focuses on the training of medical corpsmen and other front-line personnel who might be called upon to provide emergency triage on the battlefield. The system is built upon Sandia`s multi-user, distributed VR platform and provides an interactive, immersive simulation capability. The user is represented by an Avatar and is able to manipulate his virtual instruments and carry out medical procedures. A dynamic casualty simulation provides realistic cues to the patient`s condition (e.g. changing blood pressure and pulse) andmore » responds to the actions of the trainee (e.g. a change in the color of a patient`s skin may result from a check of the capillary refill rate). The current casualty simulation is of an injury resulting in a tension pneumothorax. This casualty model was developed by the University of Pennsylvania and integrated into the Sandia MediSim system.« less
Multifactorial intervention for diabetes control among older users of insulin
Machry, Rafael Vaz; Pedroso, Henrique Umpierre; Vasconcellos, Luthiele Silva; Nunes, Rafaela Ramos; Evaldt, Cibelle de Abreu; Yunes, Eduardo Bardou; Rodrigues, Ticiana da Costa
2018-01-01
ABSTRACT OBJECTIVE: To evaluate if the closer follow-up with the supply of insulin pens and the measurement of capillary blood glucose improve the management of older patients with type 2 diabetes without adequate glycemic control despite extensive therapy. METHODS: This is a prospective, non-randomized, quasi-experimental study. We have included 45 patients over 60 years old, from both sexes, with glycated hemoglobin (HbA1c) > 8.5% using oral hypoglycemic agents and insulin. The intervention consisted of monthly medical visits, with the provision of insulin pens and strips for blood glucose measurement. All patients received insulin pen, refills of Neutral Protamine Hagedorn and regular insulin, needles for the pen, blood glucose meter, and capillary blood glucose tests (three tests/day). Treatment was adjusted with the same endocrinologist monthly for six months. Glycated hemoglobin was measured at baseline and 12 and 24 weeks after intervention. RESULTS: Glycated hemoglobin at baseline was 10.34% (SE = 0.22%) and 8.54% (SE = 0.24%, p < 0.001) and 8.09% (SE = 0.21%, p < 0.001) at 12 and 24 weeks after intervention, respectively, with a significant reduction from baseline. CONCLUSIONS: More frequent medical visits, with treatment inputs including the use of insulin pens and self-monitoring, have improved glycemic control (reduction of 2.25% in HbA1C, on average, at 24 weeks of follow-up). Our data support a change in the management and medical behavior of older patients with chronically decompensated diabetes. PMID:29791677
Jeong, Erwin W; Feger, Erin; Noble, Harmony K; Kmiec, Magdalen; Prayaga, Ram S
2018-01-01
Background Nonadherence is a major concern in the management of chronic conditions such as hypertension, cardiovascular disease, and diabetes where patients may discontinue or interrupt their medication for a variety of reasons. Text message reminders have been used to improve adherence. However, few programs or studies have explored the benefits of text messaging with older populations and at scale. In this paper, we present a program design using tailored and interactive text messaging to improve refill rates of partially adherent or nonadherent Medicare members of a large integrated health plan. Objective The aim of this 3-month program was to gain an understanding of whether tailored interactive text message dialogues could be used to improve medication refills in Medicare patients with one or more chronic diseases. Methods We used the mPulse Mobile interactive text messaging solution with partially adherent and nonadherent Medicare patients (ie, over age 65 years or younger with disabilities) of Kaiser Permanente Southern California (KP), a large integrated health plan, and compared refill rates of the text messaging group (n=12,272) to a group of partially adherent or nonadherent Medicare patients at KP who did not receive text messages (nontext messaging group, n=76,068). Both groups were exposed to other forms of refill and adherence outreach including phone calls, secure emails, and robo-calls from December 2016 to February 2017. Results The text messaging group and nontext messaging group were compared using an independent samples t test to test difference in group average of refill rates. There was a significant difference in medication refill rates between the 2 groups, with a 14.07 percentage points higher refill rate in the text messaging group (P<.001). Conclusions The results showed a strong benefit of using this text messaging solution to improve medication refill rates among Medicare patients. These findings also support using interactive text messaging as a cost-effective, convenient, and user-friendly solution for patient engagement. Program outcomes and insights can be used to enhance the design of future text-based solutions to improve health outcomes and promote adherence and long-term behavior change. PMID:29382623
Design, fabrication, assembly, and test of a liquid hydrogen acquisition subsystem
NASA Technical Reports Server (NTRS)
Blackman, J. B.
1974-01-01
The development of a cryogenic fluid system to supply liquid hydrogen to a turbopump at flowrates up to 7.5 pounds per second for a period of approximately 5 seconds before refill, is discussed. Refill is accomplished in less than 10 seconds, during which a constant flowrate can be maintained to the pumps. Diagrams are provided to show the configuration of the system. Subsystem acceptance and functional tests, including acquisition subsystem expulsion, pressurization, and refill were performed. The tests included: (1) thermodynamic vent system operation, (2) warm-gas pressurization effects, (3) hydraulic pressure surge effects, (4) screen device operational limitations, (5) feedline vapor control, and (6) two-phase refill.
Psychologically Informed Implementations of Sugary-Drink Portion Limits
John, Leslie K.; Donnelly, Grant E.; Roberto, Christina A.
2017-01-01
In 2012, the New York City Board of Health prohibited restaurants from selling sugary drinks in containers that would hold more than 16 oz. Although a state court ruled that the Board of Health did not have the authority to implement such a policy, it remains a legally viable option for governments and a voluntary option for restaurants. However, there is very limited empirical data on how such a policy might affect the purchasing and consumption of sugary drinks. We report four well-powered, incentive-compatible experiments in which we evaluated two possible ways that restaurants might comply with such a policy: bundling (i.e., dividing the contents of oversized cups into two regulation-size cups) and providing free refills (i.e., offering a regulation-size cup with unlimited refills). Bundling caused people to buy less soda. Free refills increased consumption, especially when a waiter served the refills. This perverse effect was reduced in self-service contexts that required walking just a few steps to get a refill. PMID:28362567
Jönsson, Anna K.; Lesén, Eva; Mårdby, Ann-Charlotte; Sundell, Karolina Andersson
2016-01-01
Objective Generic substitution has contributed to economic savings but switching products may affect patient adherence, particularly among those using multiple medications. The aim was to analyse if use of multiple medications influenced the association between switching products and refill adherence to angiotensin-converting-enzyme (ACE) inhibitors in Sweden. Study Design and Setting New users of ACE-inhibitors, starting between 1 July 2006 and 30 June 2007, were identified in the Swedish Prescribed Drug Register. Refill adherence was assessed using the continuous measure of medication acquisition (CMA) and analysed with linear regression and analysis of covariance. Results The study population included 42735 individuals whereof 51.2% were exposed to switching ACE-inhibitor and 39.6% used multiple medications. Refill adherence was higher among those exposed to switching products than those not, but did not vary depending on the use of multiple medications or among those not. Refill adherence varied with age, educational level, household income, country of birth, previous hospitalisation and previous cardiovascular diagnosis. Conclusion The results indicate a positive association between refill adherence and switching products, mainly due to generic substitution, among new users of ACE-inhibitors in Sweden. This association was independent of use of multiple medications. PMID:27192203
McCully
1999-03-01
Embolism and refilling of vessels was monitored directly by cryomicroscopy of field-grown corn (Zea mays L.) roots. To test the reliability of an earlier study showing embolism refilling in roots at negative leaf water potentials, embolisms were counted, and root water potentials (Psiroot) and osmotic potentials of exuded xylem sap from the same roots were measured by isopiestic psychrometry. All vessels were full at dawn (Psiroot -0.1 MPa). Embolisms were first seen in late metaxylem vessels at 8 AM. Embolized late metaxylem vessels peaked at 50% at 10 AM (Psiroot -0.1 MPa), fell to 44% by 12 PM (Psiroot -0.23 MPa), then dropped steadily to zero by early evening (Psiroot -0.28 MPa). Transpiration was highest (8.5 μg cm-2 s-1) between 12 and 2 PM when the percentage of vessels embolized was falling. Embolized vessels were refilled by liquid moving through their lateral walls. Xylem sap was very low in solutes. The mechanism of vessel refilling, when Psiroot is negative, requires further investigation. Daily embolism and refilling in roots of well-watered plants is a normal occurrence and may be a component of an important hydraulic signaling mechanism between roots and shoots.
Nicotine delivery from the refill liquid to the aerosol via high-power e-cigarette device.
Prévôt, Nathalie; de Oliveira, Fabien; Perinel-Ragey, Sophie; Basset, Thierry; Vergnon, Jean-Michel; Pourchez, Jérémie
2017-06-01
To offer an enhanced and well-controlled nicotine delivery from the refill liquid to the aerosol is a key point to adequately satisfy nicotine cravings using electronic nicotine delivery systems (ENDS). A recent high-power ENDS, exhibiting higher aerosol nicotine delivery than older technologies, was used. The particle size distribution was measured using a cascade impactor. The effects of the refill liquid composition on the nicotine content of each size-fraction in the submicron range were investigated. Nicotine was quantified by liquid chromatography coupled with tandem mass spectrometry. Particle size distribution of the airborne refill liquid and the aerosol nicotine demonstrated that the nicotine is equally distributed in droplets regardless of their size. Results also proved that the nicotine concentration in aerosol was significantly lower compared to un-puffed refill liquid. A part of the nicotine may be left in the ENDS upon depletion, and consequently a portion of the nicotine may not be transferred to the user. Thus, new generation high-power ENDS associated with propylene glycol/vegetable glycerin (PG/VG) based solvent were very efficient to generate carrier-droplets containing nicotine molecules with a constant concentration. Findings highlighted that a portion of the nicotine in the refill liquid may not be transferred to the user.
Rowe, Christopher; Santos, Glenn-Milo; Vittinghoff, Eric; Wheeler, Eliza; Davidson, Peter; Coffin, Philip O
2015-08-01
To describe characteristics of participants and overdose reversals associated with a community-based naloxone distribution program and identify predictors of obtaining naloxone refills and using naloxone for overdose reversal. Bivariate statistical tests were used to compare characteristics of participants who obtained refills and reported overdose reversals versus those who did not. We fitted multiple logistic regression models to identify predictors of refills and reversals; zero-inflated multiple Poisson regression models were used to identify predictors of number of refills and reversals. San Francisco, California, USA. Naloxone program participants registered and reversals reported from 2010 to 2013. Baseline characteristics of participants and reported characteristics of reversals. A total of 2500 participants were registered and 702 reversals were reported from 2010 to 2013. Participants who had witnessed an overdose [adjusted odds ratio (AOR)=2.02, 95% confidence interval (CI)= 1.53-2.66; AOR = 2.73, 95% CI = 1.73-4.30] or used heroin (AOR = 1.85, 95% CI = 1.44-2.37; AOR = 2.19, 95% CI = 1.54-3.13) or methamphetamine (AOR=1.71, 95% CI=1.37-2.15; AOR=1.61, 95% CI=1.18-2.19) had higher odds of obtaining a refill and reporting a reversal, respectively. African American (AOR = 0.63, 95% CI = 0.45-0.88) and Latino (AOR = 0.65, 95% CI = 0.43-1.00) participants had lower odds of obtaining a naloxone refill, whereas Latino participants who obtained at least one refill reported a higher number of refills [incidence rate ratio (IRR) = 1.33 (1.05-1.69)]. Community naloxone distribution programs are capable of reaching sizeable populations of high-risk individuals and facilitating large numbers of overdose reversals. Community members most likely to engage with a naloxone program and use naloxone to reverse an overdose are active drug users. © 2015 Society for the Study of Addiction.
Lücker, Adrien; Secomb, Timothy W.; Weber, Bruno; Jenny, Patrick
2018-01-01
Capillary dysfunction impairs oxygen supply to parenchymal cells and often occurs in Alzheimer's disease, diabetes and aging. Disturbed capillary flow patterns have been shown to limit the efficacy of oxygen extraction and can be quantified using capillary transit time heterogeneity (CTH). However, the transit time of red blood cells (RBCs) through the microvasculature is not a direct measure of their capacity for oxygen delivery. Here we examine the relation between CTH and capillary outflow saturation heterogeneity (COSH), which is the heterogeneity of blood oxygen content at the venous end of capillaries. Models for the evolution of hemoglobin saturation heterogeneity (HSH) in capillary networks were developed and validated using a computational model with moving RBCs. Two representative situations were selected: a Krogh cylinder geometry with heterogeneous hemoglobin saturation (HS) at the inflow, and a parallel array of four capillaries. The heterogeneity of HS after converging capillary bifurcations was found to exponentially decrease with a time scale of 0.15–0.21 s due to diffusive interaction between RBCs. Similarly, the HS difference between parallel capillaries also drops exponentially with a time scale of 0.12–0.19 s. These decay times are substantially smaller than measured RBC transit times and only weakly depend on the distance between microvessels. This work shows that diffusive interaction strongly reduces COSH on a small spatial scale. Therefore, we conclude that CTH influences COSH yet does not determine it. The second part of this study will focus on simulations in microvascular networks from the rodent cerebral cortex. Actual estimates of COSH and CTH will then be given. PMID:29755365
Lücker, Adrien; Secomb, Timothy W; Weber, Bruno; Jenny, Patrick
2018-01-01
Capillary dysfunction impairs oxygen supply to parenchymal cells and often occurs in Alzheimer's disease, diabetes and aging. Disturbed capillary flow patterns have been shown to limit the efficacy of oxygen extraction and can be quantified using capillary transit time heterogeneity (CTH). However, the transit time of red blood cells (RBCs) through the microvasculature is not a direct measure of their capacity for oxygen delivery. Here we examine the relation between CTH and capillary outflow saturation heterogeneity (COSH), which is the heterogeneity of blood oxygen content at the venous end of capillaries. Models for the evolution of hemoglobin saturation heterogeneity (HSH) in capillary networks were developed and validated using a computational model with moving RBCs. Two representative situations were selected: a Krogh cylinder geometry with heterogeneous hemoglobin saturation (HS) at the inflow, and a parallel array of four capillaries. The heterogeneity of HS after converging capillary bifurcations was found to exponentially decrease with a time scale of 0.15-0.21 s due to diffusive interaction between RBCs. Similarly, the HS difference between parallel capillaries also drops exponentially with a time scale of 0.12-0.19 s. These decay times are substantially smaller than measured RBC transit times and only weakly depend on the distance between microvessels. This work shows that diffusive interaction strongly reduces COSH on a small spatial scale. Therefore, we conclude that CTH influences COSH yet does not determine it. The second part of this study will focus on simulations in microvascular networks from the rodent cerebral cortex. Actual estimates of COSH and CTH will then be given.
Brar Prayaga, Rena; Jeong, Erwin W; Feger, Erin; Noble, Harmony K; Kmiec, Magdalen; Prayaga, Ram S
2018-01-30
Nonadherence is a major concern in the management of chronic conditions such as hypertension, cardiovascular disease, and diabetes where patients may discontinue or interrupt their medication for a variety of reasons. Text message reminders have been used to improve adherence. However, few programs or studies have explored the benefits of text messaging with older populations and at scale. In this paper, we present a program design using tailored and interactive text messaging to improve refill rates of partially adherent or nonadherent Medicare members of a large integrated health plan. The aim of this 3-month program was to gain an understanding of whether tailored interactive text message dialogues could be used to improve medication refills in Medicare patients with one or more chronic diseases. We used the mPulse Mobile interactive text messaging solution with partially adherent and nonadherent Medicare patients (ie, over age 65 years or younger with disabilities) of Kaiser Permanente Southern California (KP), a large integrated health plan, and compared refill rates of the text messaging group (n=12,272) to a group of partially adherent or nonadherent Medicare patients at KP who did not receive text messages (nontext messaging group, n=76,068). Both groups were exposed to other forms of refill and adherence outreach including phone calls, secure emails, and robo-calls from December 2016 to February 2017. The text messaging group and nontext messaging group were compared using an independent samples t test to test difference in group average of refill rates. There was a significant difference in medication refill rates between the 2 groups, with a 14.07 percentage points higher refill rate in the text messaging group (P<.001). The results showed a strong benefit of using this text messaging solution to improve medication refill rates among Medicare patients. These findings also support using interactive text messaging as a cost-effective, convenient, and user-friendly solution for patient engagement. Program outcomes and insights can be used to enhance the design of future text-based solutions to improve health outcomes and promote adherence and long-term behavior change. ©Rena Brar Prayaga, Erwin W Jeong, Erin Feger, Harmony K Noble, Magdalen Kmiec, Ram S Prayaga. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 30.01.2018.
Knipfer, Thorsten; Cuneo, Italo F; Brodersen, Craig R; McElrone, Andrew J
2016-06-01
Gas embolisms formed during drought can disrupt long-distance water transport through plant xylem vessels, but some species have the ability to remove these blockages. Despite evidence suggesting that embolism removal is linked to the presence of vessel-associated parenchyma, the underlying mechanism remains controversial and is thought to involve positive pressure generated by roots. Here, we used in situ x-ray microtomography on excised grapevine stems to determine if embolism removal is possible without root pressure, and if the embolism formation/removal affects vessel functional status after sample excision. Our data show that embolism removal in excised stems was driven by water droplet growth and was qualitatively identical to refilling in intact plants. When stem segments were rehydrated with H2O after excision, vessel refilling occurred rapidly (<1 h). The refilling process was substantially slower when polyethylene glycol was added to the H2O source, thereby providing new support for an osmotically driven refilling mechanism. In contrast, segments not supplied with H2O showed no refilling and increased embolism formation. Dynamic changes in liquid/wall contact angles indicated that the processes of embolism removal (i.e. vessel refilling) by water influx and embolism formation by water efflux were directly linked to the activity of vessel-associated living tissue. Overall, our results emphasize that root pressure is not required as a driving force for vessel refilling, and care should be taken when performing hydraulics measurements on excised plant organs containing living vessel-associated tissue, because the vessel behavior may not be static. © 2016 American Society of Plant Biologists. All Rights Reserved.
Knipfer, Thorsten; Cuneo, Italo F.; Brodersen, Craig R.; McElrone, Andrew J.
2016-01-01
Gas embolisms formed during drought can disrupt long-distance water transport through plant xylem vessels, but some species have the ability to remove these blockages. Despite evidence suggesting that embolism removal is linked to the presence of vessel-associated parenchyma, the underlying mechanism remains controversial and is thought to involve positive pressure generated by roots. Here, we used in situ x-ray microtomography on excised grapevine stems to determine if embolism removal is possible without root pressure, and if the embolism formation/removal affects vessel functional status after sample excision. Our data show that embolism removal in excised stems was driven by water droplet growth and was qualitatively identical to refilling in intact plants. When stem segments were rehydrated with H2O after excision, vessel refilling occurred rapidly (<1 h). The refilling process was substantially slower when polyethylene glycol was added to the H2O source, thereby providing new support for an osmotically driven refilling mechanism. In contrast, segments not supplied with H2O showed no refilling and increased embolism formation. Dynamic changes in liquid/wall contact angles indicated that the processes of embolism removal (i.e. vessel refilling) by water influx and embolism formation by water efflux were directly linked to the activity of vessel-associated living tissue. Overall, our results emphasize that root pressure is not required as a driving force for vessel refilling, and care should be taken when performing hydraulics measurements on excised plant organs containing living vessel-associated tissue, because the vessel behavior may not be static. PMID:27208267
Zapka, Carrie A.; Campbell, Esther J.; Maxwell, Sheri L.; Gerba, Charles P.; Dolan, Michael J.; Arbogast, James W.; Macinga, David R.
2011-01-01
Bulk-soap-refillable dispensers are prone to extrinsic bacterial contamination, and recent studies demonstrated that approximately one in four dispensers in public restrooms are contaminated. The purpose of this study was to quantify bacterial hand contamination and transfer after use of contaminated soap under controlled laboratory and in-use conditions in a community setting. Under laboratory conditions using liquid soap experimentally contaminated with 7.51 log10 CFU/ml of Serratia marcescens, an average of 5.28 log10 CFU remained on each hand after washing, and 2.23 log10 CFU was transferred to an agar surface. In an elementary-school-based field study, Gram-negative bacteria on the hands of students and staff increased by 1.42 log10 CFU per hand (26-fold) after washing with soap from contaminated bulk-soap-refillable dispensers. In contrast, washing with soap from dispensers with sealed refills significantly reduced bacteria on hands by 0.30 log10 CFU per hand (2-fold). Additionally, the mean number of Gram-negative bacteria transferred to surfaces after washing with soap from dispensers with sealed-soap refills (0.06 log10 CFU) was significantly lower than the mean number after washing with contaminated bulk-soap-refillable dispensers (0.74 log10 CFU; P < 0.01). Finally, significantly higher levels of Gram-negative bacteria were recovered from students (2.82 log10 CFU per hand) than were recovered from staff (2.22 log10 CFU per hand) after washing with contaminated bulk soap (P < 0.01). These results demonstrate that washing with contaminated soap from bulk-soap-refillable dispensers can increase the number of opportunistic pathogens on the hands and may play a role in the transmission of bacteria in public settings. PMID:21421792
Bacterial hand contamination and transfer after use of contaminated bulk-soap-refillable dispensers.
Zapka, Carrie A; Campbell, Esther J; Maxwell, Sheri L; Gerba, Charles P; Dolan, Michael J; Arbogast, James W; Macinga, David R
2011-05-01
Bulk-soap-refillable dispensers are prone to extrinsic bacterial contamination, and recent studies demonstrated that approximately one in four dispensers in public restrooms are contaminated. The purpose of this study was to quantify bacterial hand contamination and transfer after use of contaminated soap under controlled laboratory and in-use conditions in a community setting. Under laboratory conditions using liquid soap experimentally contaminated with 7.51 log(10) CFU/ml of Serratia marcescens, an average of 5.28 log(10) CFU remained on each hand after washing, and 2.23 log(10) CFU was transferred to an agar surface. In an elementary-school-based field study, Gram-negative bacteria on the hands of students and staff increased by 1.42 log(10) CFU per hand (26-fold) after washing with soap from contaminated bulk-soap-refillable dispensers. In contrast, washing with soap from dispensers with sealed refills significantly reduced bacteria on hands by 0.30 log(10) CFU per hand (2-fold). Additionally, the mean number of Gram-negative bacteria transferred to surfaces after washing with soap from dispensers with sealed-soap refills (0.06 log(10) CFU) was significantly lower than the mean number after washing with contaminated bulk-soap-refillable dispensers (0.74 log(10) CFU; P < 0.01). Finally, significantly higher levels of Gram-negative bacteria were recovered from students (2.82 log(10) CFU per hand) than were recovered from staff (2.22 log(10) CFU per hand) after washing with contaminated bulk soap (P < 0.01). These results demonstrate that washing with contaminated soap from bulk-soap-refillable dispensers can increase the number of opportunistic pathogens on the hands and may play a role in the transmission of bacteria in public settings.
The Dynamics of Embolism Refilling in Abscisic Acid (ABA)-Deficient Tomato Plants
Secchi, Francesca; Perrone, Irene; Chitarra, Walter; Zwieniecka, Anna K.; Lovisolo, Claudio; Zwieniecki, Maciej A.
2013-01-01
Plants are in danger of embolism formation in xylem vessels when the balance between water transport capacity and transpirational demand is compromised. To maintain this delicate balance, plants must regulate the rate of transpiration and, if necessary, restore water transport in embolized vessels. Abscisic acid (ABA) is the dominant long-distance signal responsible for plant response to stress, and it is possible that it plays a role in the embolism/refilling cycle. To test this idea, a temporal analysis of embolism and refilling dynamics, transpiration rate and starch content was performed on ABA-deficient mutant tomato plants. ABA-deficient mutants were more vulnerable to embolism formation than wild-type plants, and application of exogenous ABA had no effect on vulnerability. However, mutant plants treated with exogenous ABA had lower stomatal conductance and reduced starch content in the xylem parenchyma cells. The lower starch content could have an indirect effect on the plant’s refilling activity. The results confirm that plants with high starch content (moderately stressed mutant plants) were more likely to recover from loss of water transport capacity than plants with low starch content (mutant plants with application of exogenous ABA) or plants experiencing severe water stress. This study demonstrates that ABA most likely does not play any direct role in embolism refilling, but through the modulation of carbohydrate content, it could influence the plant’s capacity for refilling. PMID:23263667
Pharmaceutical policies used by private health insurance companies in Saudi Arabia.
Bawazir, Saleh A; Alkudsi, Mohammed A; Al Humaidan, Abdullah S; Al Jaser, Maher A; Sasich, Larry D
2013-07-01
Currently, the Council of Cooperative Health Insurance (CCHI) is the body responsible for regulating health insurance in the KSA. While the cooperative health insurance schedule (i.e., model policy for health insurance) is available on the CCHI web site, policies related to pharmaceuticals are ambiguous. The primary objective of this study was to assess the impact of health insurance policies provided by health insurance companies in KSA on access to medication and its use. This study was descriptive in design and used a survey, which was conducted through face-to-face interviews with the medical managers of health insurance companies. The survey took place between March and June, 2011. All 25 insurance companies accredited by CCHI were eligible to be included in the study. Out of these 25 companies, three were excluded from this survey as no response was received. All the 16 companies responded "Yes" that they had a prior authorization policy; however, their reasons varied. Eight (50%) of the companies were concerned about the duration of treatment. While 10 (62.5%) did not offer additional coverage over the CCHI model policy, the other 6 (37.5%) reported that they could reconcile certain conditions. The survey also demonstrated that 10 insurance companies allowed refilling of medication but with certain limitations. Six out of the 10 permitted refilling within a maximum time of three months, whereas the other four companies did not have any time-based limits for refilling. The other six companies did not allow refilling without prescription. Although this paper was primarily descriptive, the findings revealed a substantial scope for improvement in terms of pharmaceutical policy standards and regulation in the health insurance companies in KSA. Additionally, the study highlighted such areas to augment the overall quality use of medication, over-prescribing and irrational use of medication. Further research, thus, is definitely needed.
Pharmaceutical policies used by private health insurance companies in Saudi Arabia
Bawazir, Saleh A.; Alkudsi, Mohammed A.; Al Humaidan, Abdullah S.; Al Jaser, Maher A.; Sasich, Larry D.
2012-01-01
Background Currently, the Council of Cooperative Health Insurance (CCHI) is the body responsible for regulating health insurance in the KSA. While the cooperative health insurance schedule (i.e., model policy for health insurance) is available on the CCHI web site, policies related to pharmaceuticals are ambiguous. Aims The primary objective of this study was to assess the impact of health insurance policies provided by health insurance companies in KSA on access to medication and its use. Settings and Design This study was descriptive in design and used a survey, which was conducted through face-to-face interviews with the medical managers of health insurance companies. Methods and Material The survey took place between March and June, 2011. All 25 insurance companies accredited by CCHI were eligible to be included in the study. Out of these 25 companies, three were excluded from this survey as no response was received. Results All the 16 companies responded “Yes” that they had a prior authorization policy; however, their reasons varied. Eight (50%) of the companies were concerned about the duration of treatment. While 10 (62.5%) did not offer additional coverage over the CCHI model policy, the other 6 (37.5%) reported that they could reconcile certain conditions. The survey also demonstrated that 10 insurance companies allowed refilling of medication but with certain limitations. Six out of the 10 permitted refilling within a maximum time of three months, whereas the other four companies did not have any time-based limits for refilling. The other six companies did not allow refilling without prescription. Conclusions Although this paper was primarily descriptive, the findings revealed a substantial scope for improvement in terms of pharmaceutical policy standards and regulation in the health insurance companies in KSA. Additionally, the study highlighted such areas to augment the overall quality use of medication, over-prescribing and irrational use of medication. Further research, thus, is definitely needed. PMID:23960843
Carter, Chureen T; Changolkar, Arun K; Scott McKenzie, R
2012-01-01
To evaluate the utilization patterns of the anti-tumor necrosis factor (anti-TNF) agents Humira (adalimumab), Enbrel (etanercept), and Remicade (infliximab) in patients with rheumatoid arthritis (RA) and compare medication costs during the first year of treatment. (Humira is a registered trademark of Abbott Laboratories, IL; Enbrel is a registered trademark of Immunex Corporation, CA; and Remicade is a registered trademark of Janssen Biotech, Inc., PA). This retrospective analysis of medical and pharmacy claims included patients who were aged ≥18 years, had ≥2 RA diagnosis codes, and had ≥365 days of persistence with the index anti-TNF. Patients excluded had claims for anti-TNF agents within 6 months before the index date. Refill patterns for adalimumab and etanercept, number of infliximab infusions, time between infusions, and dose per infusion were analyzed for 12 months. Direct anti-TNF medication costs were compared among anti-TNFs for the initial treatment year. Infliximab-treated patients (n = 457) were significantly older than adalimumab- (n = 337) or etanercept-treated patients (n = 902). Time between refills was longer than recommended for 28% and 30% of adalimumab and etanercept refill periods, respectively. Potential cumulative time without therapy was 33 days for adalimumab and 43 days for etanercept. Statistically significant differences in mean per-patient anti-TNF medication costs for the first year were reported for adalimumab, etanercept, and infliximab ($14,991, $13,361, and $18,139, respectively; p < 0.0001); however, a cost assessment using labeled dosing of the anti-TNF agents with optimal treatment compliance yielded comparable annual medication costs. This analysis only evaluated utilization patterns for selected anti-TNF agents and was not inclusive of other medications that patients may have been using for RA. Absolute patient adherence could not be assessed due to lack of information on how patients were self-administering adalimumab and etanercept or if samples of the agents were made available. This study identified gaps in patients' refills compared with prescriber recommendations. The infliximab-treated group had infusion patterns consistent with prescribing information. Potential clinical and economic implications of dose attenuation with adalimumab and etanercept should be explored further.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bondarenko, Anton; Vyvenko, Oleg
2014-02-21
Dislocation network (DN) at hydrophilically bonded Si wafers interface is placed in space charge region (SCR) of a Schottky diode at a depth of about 150 nm from Schottky electrode for simultaneous investigation of its electrical and luminescent properties. Our recently proposed pulsed traps refilling enhanced luminescence (Pulsed-TREL) technique based on the effect of transient luminescence induced by refilling of charge carrier traps with electrical pulses is further developed and used as a tool to establish DN energy levels responsible for D1 band of dislocation-related luminescence in Si (DRL). In present work we do theoretical analysis and simulation of trapsmore » refilling kinetics dependence on refilling pulse magnitude (Vp) in two levels model: shallow and deep. The influence of initial charge state of deep level on shallow level occupation-Vp dependence is discussed. Characteristic features predicted by simulations are used for Pulsed-TREL experimental results interpretation. We conclude that only shallow (∼0.1 eV from conduction and valence band) energetic levels in the band gap participate in D1 DRL.« less
A gap analysis approach to assess patient persistence with glaucoma medication.
Lee, Paul P; Walt, John G; Chiang, Tina H; Guckian, Angela; Keener, John
2007-10-01
To develop an alternative method for analysis of patient persistence with prescribed medications using the prostaglandin class of intraocular pressure (IOP)-lowering drugs as a model. A retrospective study of prescription refill patterns. Patients with a pharmacy claim for a 2.5 ml bottle of latanoprost, travoprost, or bimatoprost between September 1, 2002 and December 31, 2002 were identified from a retail pharmacy database and were followed up for 12 months. Three separate analyses defined gaps in therapy as spans in excess of 45, 60, or 120 days without a refill for the same medication. Patients were categorized by the number of gaps in therapy and the cumulative length of gaps. A Kaplan-Meier analysis was conducted using a 120-day allowable refill period. For refill periods of 45, 60, and 120 days, 10.6%, 28.6%, and 77.5% of patients, respectively, had no gaps in therapy, and 32.6%, 53.4%, and 86.5%, respectively, had 30 days or fewer off therapy annually. According to the 45-day threshold analysis, 50.7% of patients had three or more gaps vs 18.5% in the 60-day analysis and none in the 120-day analysis. The Kaplan-Meier curve shows 88.6% and 76.1% of patients were persistent for 120 days and one year, respectively. Compared with Kaplan-Meier survival curves, the gap analysis approach may better parallel clinical experience with patient persistence, in which patients stop and restart medications for a variety of reasons over time. This method also may help to identify avenues for investigation of lack of persistency among many patients.
MEDICAL PRACTICE IN CHILDREN PRESENTING FEVER WITH PETECHIAL RASH TO AN EMERGENCY DEPARTMENT.
Dumitrascu-Biris, Ioana; Chirita-Emandi, Adela; Lambert, Imelda; Marginean, Otilia; Sharif, Farhana
2016-01-01
The association of fever and petechiae in children is one of the most alarming findings for a paediatrician. To quickly distinguish between benign and life-threatening conditions is challenging in many cases. We aimed to evaluate the clinical practice of children presenting with fever and petechiae as initial symptoms. 41 patients (age 3 months-11 years) presenting with fever and petechiae were identified in an Emergency Paediatric Assessment Unit over a period of 9 months. General data, symptoms and signs were assessed for each patient. The work-up consisted in: complete blood count, inflammatory tests, coagulation tests, Monospot test, nasopharyngeal rapid tests, blood culture, and cerebrospinal fluid culture where appropriate. Most children were <5 years of age (70.7%). Female to male ratio was 1:2.4. The most common clinical diagnoses were: viral respiratory illness (48.8%, 20/41) and upper respiratory tract infection (17.1%, 7/41). Meningococcal disease was found in one case. CRP>6 mg/l was poorly correlated with serious illness. The following variables were strongly associated with serious illness: ill appearance, shivering, lethargy, back rigidity, ESR>50 mm/h and prolonged capillary refill time. 59% (24/41) of children were treated with antibiotics, however, at discharge 42%(10/24) of them, did not have a work-up suggestive for a bacterial illness. Screening for low prevalence but high morbidity conditions, as the meningococcal disease, with an extensive work-up is time and resource consuming and may lead to unmotivated antibiotic use. Larger studies are needed to change the emergency practice for management of fever and rash.
Mathematical Model for the Mineralization of Bone
NASA Technical Reports Server (NTRS)
Martin, Bruce
1994-01-01
A mathematical model is presented for the transport and precipitation of mineral in refilling osteons. One goal of this model was to explain calcification 'halos,' in which the bone near the haversian canal is more highly mineralized than the more peripheral lamellae, which have been mineralizing longer. It was assumed that the precipitation rate of mineral is proportional to the difference between the local concentration of calcium ions and an equilibrium concentration and that the transport of ions is by either diffusion or some other concentration gradient-dependent process. Transport of ions was assumed to be slowed by the accumulation of mineral in the matrix along the transport path. ne model also mimics bone apposition, slowing of apposition during refilling, and mineralization lag time. It was found that simple diffusion cannot account for the transport of calcium ions into mineralizing bone, because the diffusion coefficient is two orders of magnitude too low. If a more rapid concentration gradient-driven means of transport exists, the model demonstrates that osteonal geometry and variable rate of refilling work together to produce calcification halos, as well as the primary and secondary calcification effect reported in the literature.
Signs Indicating Imminent Death in Escherichia coli-Infected Broilers.
Matthijs, M G R; Nieuwenhuis, J F; Dwars, R M
2017-09-01
Broilers were observed during 9 days for clinical signs after intratracheal inoculation at 8 days of age with 10 7 E. coli 506. It was determined if these signs were predictive for imminent death. Hourly observations were made daily from a distance of 1-2 m and nightly by camera observation, with respect to the following parameters: level of attention, locomotory activity, posture and appearance, interaction, and impairment of respiration. For deviations of the normal state for these five parameters (i.e., typical clinical signs of disease), scores were defined in up to four classes. The periods of time elapsing from attaining a score for the first time to death were registered per bird for each score for each parameter. Of 114 birds, 85 did not present typical signs of illness as described, and 29 presented the following clinical history: 25 died after presenting signs of illness, 2 died without previous signs, 1 fell ill but survived, and 1 fell ill and recovered. Extended clinical examination was performed in birds presenting clinical signs; temperature, heart rate, respiratory rate, and subcutaneous capillary refill time were measured. The level of attention, and posture and appearance were affected most often in ill birds; 25% of these birds died within 5 and 4 hr, respectively; 50% died within 12 hr; and 75% died within 20 and 19 hr, respectively. Any of these typical signs of illness visible from 1-2 m indicated imminent death, with 75% of the birds dying within 20 hr. Measurements resulting from extended clinical examination proved of lesser predictive value. From these observations, a protocol for intervention to prevent animal suffering may be designed.
Comparison of ultrarapid and rapid intravenous hydration in pediatric patients with dehydration.
Nager, Alan L; Wang, Vincent J
2010-02-01
The purpose of this study is to test the efficacy of ultrarapidly infused vs rapidly infused intravenous (IV) hydration in pediatric patients with acute gastroenteritis and moderate dehydration. Patients 3 to 36 months, with vomiting and/or diarrhea and moderate dehydration, were eligible. Subjects were randomly assigned "ultra" (50 mL/kg normal saline for 1 hour) vs "standard" (50 mL/kg normal saline for 3 hours) after failing an oral fluid challenge. Subjects were weighed and had serum electrolyte testing, and urine was obtained before/after IV hydration. Input/output and vital signs were tabulated hourly during the study. Subjects were discharged after fulfilling specified criteria. A follow-up questionnaire was completed 24 hours after discharge. Comparison data included success and timing of rehydration, number of patients who returned and/or were admitted, output during the rehydration period, laboratory differences, and serious complications. Eighty-eight of 92 subjects completed the study: 45 ultra and 43 standard. Four patients failed treatment (1 ultra and 3 standard), were hospitalized, and excluded from the study. Groups were similar regarding sex, days of symptoms, episodes of vomiting/diarrhea before treatment, capillary refill time, tears, and vital signs and laboratory results. No subject had evidence of serious complications. Ninety-one percent of subjects completed the follow-up questionnaire. Seven ultra and 6 standard subjects returned. Six ultra subjects received oral fluid, one received IV fluid, and all were discharged. Five standard subjects received oral fluid, one received IV fluid, and all were discharged. Based on this pilot study, ultrarapid hydration for 1 hour preliminarily appears to be an efficacious alternative to standard rapid hydration for 3 hours and improves emergency department throughput time. Copyright 2010 Elsevier Inc. All rights reserved.
Measurement and modeling of the refilling plasmasphere during 2001
Krall, J.; Huba, J. D.; Jordanova, V. K.; ...
2016-03-18
The Naval Research Laboratory SAMI3 (Sami3 is Also a Model of the Ionosphere) and the RAM-CPL (Ring current Atmosphere interaction Model-Cold PLasma) codes are used to model observed plasmasphere dynamics during 25 November 2001 to 1 December 2001 and 1–5 February 2001. Model results compare well to plasmasphere observations of electron and mass densities. Comparison of model results to refilling data and to each other shows good agreement, generally within a factor of 2. We find that SAMI3 plasmaspheric refilling rates and ion densities are sensitive to the composition and temperature of the thermosphere and exosphere, and to photoelectron heating.more » Furthermore, results also support our previous finding that the wind-driven dynamo significantly impacts both refilling rates and plasmasphere dynamics during quiet periods.« less
Measurement and modeling of the refilling plasmasphere during 2001
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krall, J.; Huba, J. D.; Jordanova, V. K.
The Naval Research Laboratory SAMI3 (Sami3 is Also a Model of the Ionosphere) and the RAM-CPL (Ring current Atmosphere interaction Model-Cold PLasma) codes are used to model observed plasmasphere dynamics during 25 November 2001 to 1 December 2001 and 1–5 February 2001. Model results compare well to plasmasphere observations of electron and mass densities. Comparison of model results to refilling data and to each other shows good agreement, generally within a factor of 2. We find that SAMI3 plasmaspheric refilling rates and ion densities are sensitive to the composition and temperature of the thermosphere and exosphere, and to photoelectron heating.more » Furthermore, results also support our previous finding that the wind-driven dynamo significantly impacts both refilling rates and plasmasphere dynamics during quiet periods.« less
Code of Federal Regulations, 2011 CFR
2011-04-01
... DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL COLOR ADDITIVE PETITIONS General... limitation will begin to run anew. If nonclinical laboratory studies are involved, additional information and... to a future filing. Upon refiling, the time limitation will begin to run anew from the date of...
Neumann, M; Herten, D P; Dietrich, A; Wolfrum, J; Sauer, M
2000-02-25
The first capillary array scanner for time-resolved fluorescence detection in parallel capillary electrophoresis based on semiconductor technology is described. The system consists essentially of a confocal fluorescence microscope and a x,y-microscope scanning stage. Fluorescence of the labelled probe molecules was excited using a short-pulse diode laser emitting at 640 nm with a repetition rate of 50 MHz. Using a single filter system the fluorescence decays of different labels were detected by an avalanche photodiode in combination with a PC plug-in card for time-correlated single-photon counting (TCSPC). The time-resolved fluorescence signals were analyzed and identified by a maximum likelihood estimator (MLE). The x,y-microscope scanning stage allows for discontinuous, bidirectional scanning of up to 16 capillaries in an array, resulting in longer fluorescence collection times per capillary compared to scanners working in a continuous mode. Synchronization of the alignment and measurement process were developed to allow for data acquisition without overhead. Detection limits in the subzeptomol range for different dye molecules separated in parallel capillaries have been achieved. In addition, we report on parallel time-resolved detection and separation of more than 400 bases of single base extension DNA fragments in capillary array electrophoresis. Using only semiconductor technology the presented technique represents a low-cost alternative for high throughput DNA sequencing in parallel capillaries.
Cerebral capillary velocimetry based on temporal OCT speckle contrast.
Choi, Woo June; Li, Yuandong; Qin, Wan; Wang, Ruikang K
2016-12-01
We propose a new optical coherence tomography (OCT) based method to measure red blood cell (RBC) velocities of single capillaries in the cortex of rodent brain. This OCT capillary velocimetry exploits quantitative laser speckle contrast analysis to estimate speckle decorrelation rate from the measured temporal OCT speckle signals, which is related to microcirculatory flow velocity. We hypothesize that OCT signal due to sub-surface capillary flow can be treated as the speckle signal in the single scattering regime and thus its time scale of speckle fluctuations can be subjected to single scattering laser speckle contrast analysis to derive characteristic decorrelation time. To validate this hypothesis, OCT measurements are conducted on a single capillary flow phantom operating at preset velocities, in which M-mode B-frames are acquired using a high-speed OCT system. Analysis is then performed on the time-varying OCT signals extracted at the capillary flow, exhibiting a typical inverse relationship between the estimated decorrelation time and absolute RBC velocity, which is then used to deduce the capillary velocities. We apply the method to in vivo measurements of mouse brain, demonstrating that the proposed approach provides additional useful information in the quantitative assessment of capillary hemodynamics, complementary to that of OCT angiography.
Orbital refill of propulsion vehicle tankage
NASA Technical Reports Server (NTRS)
Merino, F.; Risberg, J. A.; Hill, M.
1980-01-01
Techniques for orbital refueling of space based vehicles were developed and experimental programs to verify these techniques were identified. Orbital refueling operations were developed for two cryogenic orbital transfer vehicles (OTV's) and an Earth storable low thrust liquid propellant vehicle. Refueling operations were performed assuming an orbiter tanker for near term missions and an orbital depot. Analyses were conducted using liquid hydrogen and N2O4. The influence of a pressurization system and acquisition device on operations was also considered. Analyses showed that vehicle refill operations will be more difficult with a cryogen than with an earth storable. The major elements of a successful refill with cryogens include tank prechill and fill. Propellant quantities expended for tank prechill appear to to insignificant. Techniques were identified to avoid loss of liquid or excessive tank pressures during refill. It was determined that refill operations will be similar whether or not an orbiter tanker or orbital depot is available. Modeling analyses were performed for prechill and fill tests to be conducted assuming the Spacelab as a test bed, and a 1/10 scale model OTV (with LN2 as a test fluid) as an experimental package.
Secchi, Francesca; Gilbert, Matthew E.; Zwieniecki, Maciej A.
2011-01-01
The mechanism of embolism repair in transpiring plants is still not understood, despite significant scientific effort. The refilling process is crucial to maintaining stem transport capacity and ensuring survival for plants experiencing dynamic changes in water stress. Refilling air-filled xylem vessels requires an energy and water source that can only be provided by adjacent living parenchyma cells. Here, we report an analysis of the transcriptome response of xylem parenchyma cells after embolism formation in Populus trichocarpa trees. Genes encoding aquaporins, ion transporters, and carbohydrate metabolic pathways were up-regulated, and there was a significant reduction in the expression of genes responding to oxidative stress. Thus, a novel view of the plant response to embolism emerges that suggests a role for oxygen in embolized vessels as a signal triggering xylem refilling and for the activity of cation transport as having a significant role in the generation of the energy gradient necessary to heal embolized vessels. These findings redefine current hypotheses surrounding the refilling phenomenon and provide insight into the complexity of the biological response to the seemingly simple physical event of xylem embolism formation. PMID:21951466
Review of microscopic plasma processes of occurring during refilling of the plasmasphere
NASA Technical Reports Server (NTRS)
Singh, N.; Torr, D. G.
1988-01-01
Refilling of the plasmashere after geomagnetic storms involves both macroscopic and microscopic plasma processes. The latter types of processes facilitate the refilling by trapping the plasma in the flux tube and by thermalizing the interhemispheric flow. A review of studies on microscopic processes is presented. The primary focus in this review is on the processes when the density is low and the plasma is collisionless. The discussion includes electrostatic shock formation, pitch angle scatterring extended ion heating and localized ion heating in the equatorial region.
Ooeda, Hiroki; Terashima, Ichiro; Taneda, Haruhiko
2017-02-01
Two hypotheses have been proposed to explain the mechanism preventing the refilling vessel water from being drained to the neighboring functional vessels under negative pressure. The pit membrane osmosis hypothesis proposes that the xylem parenchyma cells release polysaccharides that are impermeable to the intervessel pit membranes into the refilling vessel; this osmotically counteracts the negative pressure, thereby allowing the vessel to refill. The pit valve hypothesis proposes that gas trapped within intervessel bordered pits isolates the refilling vessel water from the surrounding functional vessels. Here, using the single-vessel method, we assessed these hypotheses in shoots of mulberry (Morus australis Poir.). First, we confirmed the occurrence of xylem refilling under negative pressure in the potted mulberry saplings. To examine the pit membrane osmosis hypothesis, we estimated the semi-permeability of pit membranes for molecules of various sizes and found that the pit membranes were not semi-permeable to polyethylene glycol of molecular mass <20,000. For the pit valve hypothesis, we formed pit valves in the intervessel pits in the short stem segments and measured the maximum liquid pressure up to which gases in bordered pits were retained. The threshold pressure ranged from 0.025 to 0.10 MPa. These values matched the theoretical value calculated from the geometry of the pit chamber (0.0692-0.101 MPa). Our results suggest that gas in the pits is retained by surface tension, even under substantial positive pressure to resolve gases in the refilling vessel, whereas the molecule size required for the pit membrane osmosis mechanism in mulberry would be unrealistically large. © The Author 2016. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Optimal Hedging Rule for Reservoir Refill Operation
NASA Astrophysics Data System (ADS)
Wan, W.; Zhao, J.; Lund, J. R.; Zhao, T.; Lei, X.; Wang, H.
2015-12-01
This paper develops an optimal reservoir Refill Hedging Rule (RHR) for combined water supply and flood operation using mathematical analysis. A two-stage model is developed to formulate the trade-off between operations for conservation benefit and flood damage in the reservoir refill season. Based on the probability distribution of the maximum refill water availability at the end of the second stage, three zones are characterized according to the relationship among storage capacity, expected storage buffer (ESB), and maximum safety excess discharge (MSED). The Karush-Kuhn-Tucker conditions of the model show that the optimality of the refill operation involves making the expected marginal loss of conservation benefit from unfilling (i.e., ending storage of refill period less than storage capacity) as nearly equal to the expected marginal flood damage from levee overtopping downstream as possible while maintaining all constraints. This principle follows and combines the hedging rules for water supply and flood management. A RHR curve is drawn analogously to water supply hedging and flood hedging rules, showing the trade-off between the two objectives. The release decision result has a linear relationship with the current water availability, implying the linearity of RHR for a wide range of water conservation functions (linear, concave, or convex). A demonstration case shows the impacts of factors. Larger downstream flood conveyance capacity and empty reservoir capacity allow a smaller current release and more water can be conserved. Economic indicators of conservation benefit and flood damage compete with each other on release, the greater economic importance of flood damage is, the more water should be released in the current stage, and vice versa. Below a critical value, improving forecasts yields less water release, but an opposing effect occurs beyond this critical value. Finally, the Danjiangkou Reservoir case study shows that the RHR together with a rolling horizon decision approach can lead to a gradual dynamic refilling, indicating its potential for practical use.
27 CFR 31.202 - Possession of refilled liquor bottles.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Liquor Bottles § 31.202 Possession of refilled liquor bottles. No person who sells, or offers for sale... bottle, any portion of the contents of which has been altered or increased in violation of the provisions...
NASA Astrophysics Data System (ADS)
Lu, Y.; Duursma, R.; Farrior, C.; Medlyn, B. E.
2016-12-01
Stomata control the exchange of soil water for atmospheric CO2, which is one of the most important resource trade-offs for plants. This trade-off has been studied a lot but not in the context of competition. Based on the theory of evolutionarily stable strategy, we search for the uninvadable (or the ESS) response of stomatal conductance to soil water content under stochastic rainfall, with which the dominant plant population should never be invaded by any rare mutants in the water competition due to a higher fitness. In this study, we define the fitness as the difference between the long-term average photosynthetic carbon gain and a carbon cost of stomatal opening. This cost has traditionally been considered an unknown constant. Here we extend this framework by assuming it as the energy required for xylem embolism refilling. With regard to the refilling process, we explore 2 questions 1) to what extent the embolized xylem vessels can be repaired via refilling; and 2) whether this refilling is immediate or has a time delay following the formation of xylem embolism. We compare various assumptions in a total of 5 scenarios and find that the ESS exists only if the xylem damage can be repaired completely. Then, with this ESS, we estimate annual vegetation photosynthesis and water consumption and compare them with empirical results. In conclusion, this study provides a different insight from the existing empirical and mechanistic models as well as the theoretical models based on the optimization theory. In addition, as the model result is a simple quantitative relation between stomatal conductance and soil water content, it can be easily incorporated into other vegetation function models.
Accommodation-Amplitudes following an Accommodative Lens Refilling Procedure — an in vivo Update
Nishi, Okihiro; Nishi, Yutaro; Chang, S.; Nishi, Kayo
2014-01-01
Purpose To investigate whether a newly developed lens refilling procedure can provide some accommodation in monkey eyes and to evaluate the difference in accommodation with different degrees of capsular bag refilling. Setting Jinshikai Medical Foundation, Nishi Eye Hospital, Osaka, Japan. Design Experimental monkey study. Methods Following a central 3–4 mm continuous curvilinear capsulorhexis, phacoemulsification was performed in the usual manner. A novel accommodative membrane intraocular lens for sealing capsular opening was implanted into the capsular bag. Silicone polymers were injected beneath the intraocular lens into the capsular bag through the delivery hole. In three study groups, each with six monkey eyes, the lens capsule was refilled with 0.08 ml corresponding to 65% bag volume, 0.1 ml corresponding to 80% bag volume, and 0.125 ml of silicone polymers corresponding to 100% bag volume, respectively. To calculate the accommodation-amplitudes achieved, automated refractometry was performed before and 1 hour after the topical 4% pilocarpine application before and four weeks after surgery. Results The refilling technique was successful in all monkeys without polymer leakage. Accommodation-amplitudes attained were 2.56 ± 0.74 dioptries (D), 2.42 ± 1.00D, and 2.71 ± 0.63D, respectively, 4 weeks after surgery in the three study groups. Conclusions Using the technique, some accommodation could be obtained in the young monkey eyes. Leakage of the injectable silicone polymer and anterior capsular opacification at least in the visual axis could be avoided. The results suggest that this lens refilling procedure warrants further studies for a possible clinical application. PMID:24461501
Hopkins using FSS to refill ITCS
2014-01-31
ISS038-E-040111 (31 Jan. 2014) --- NASA astronaut Mike Hopkins, Expedition 38 flight engineer, uses the Fluid Servicing System (FSS) to refill Internal Thermal Control System (ITCS) loops with fresh coolant in the Destiny laboratory of the International Space Station.
Lindgren conducts Veg-01 Plant Pillow Refill
2015-12-02
Flight engineer Kjell Lindgren poses with zinnia plants in the Veggie facility during Plant Pillow water refill operations. Image was taken in the Columbus European Laboratory and released by Lindgren on social media. "Our zinnias are looking good! #SpaceGardener"
Pichler, Gerhard; Pocivalnik, Mirjam; Riedl, Regina; Pichler-Stachl, Elisabeth; Morris, Nicholas; Zotter, Heinz; Müller, Wilhelm; Urlesberger, Berndt
2011-08-01
Interpretation of peripheral circulation in ill neonates is crucial but difficult. The aim was to analyse parameters potentially influencing peripheral oxygenation and circulation. In a prospective observational cohort study in 116 cardio-circulatory stable neonates, peripheral muscle near-infrared spectroscopy (NIRS) with venous occlusion was performed. Tissue oxygenation index (TOI), mixed venous oxygenation (SvO(2)), fractional oxygen extraction (FOE), fractional tissue oxygen extraction (FTOE), haemoglobin flow (Hbflow), oxygen delivery (DO(2)), oxygen consumption (VO(2)), and vascular resistance (VR) were assessed. Correlation coefficients between NIRS parameters and demographic parameters (gestational age, birth weight, age, actual weight, diameter of calf, subcutaneous adipose tissue), monitoring parameters (heart rate, arterial oxygen saturation (SaO(2)), mean blood pressure (MAP), core/peripheral temperature, central/peripheral capillary refill time) and laboratory parameters (haemoglobin concentration (Hb-blood), pCO(2)) were calculated. All demographic parameters except for Hbflow and DO(2) correlated with NIRS parameters. Heart rate correlated with TOI, SvO(2), VO(2) and VR. SaO(2) correlated with FOE/FTOE. MAP correlated with Hbflow, DO(2), VO(2) and VR. Core temperature correlated with FTOE. Peripheral temperature correlated with all NIRS parameters except VO(2). Hb-blood correlated with FOE and VR. pCO(2) levels correlated with TOI and SvO(2). The presence of multiple interdependent factors associated with peripheral oxygenation and circulation highlights the difficulty in interpreting NIRS data. Nevertheless, these findings have to be taken into account when analysing peripheral oxygenation and circulation data.
Fluid Interfaces of Triangular Containers in Reduced Gravity Environments
NASA Technical Reports Server (NTRS)
Guttromson, Jayleen; Manning, Robert; Collicott, Steven H.
2002-01-01
Capillary dominated fluid dynamics will be examined in a reduced-gravity environment onboard the KC-135; in particular, the behavior of the lower portion of the meniscus in triangular tank geometries. Seven clear acrylic tanks were constructed to view seven angles of the four geometries. Silicon oil with two different viscosities, 2cs and 5cs silicon oil, were used on different days of the flight. Six tanks and one control tank are filled with a certain viscosity fluid for each flight day. During each parabola, three tanks are tested at time. The experimental tanks are exchanged between parabola sets on the KC-135. The 60deg -60deg -60deg control tank is viewed throughout the flight. To gather data, two digital video cameras and one digital still camera are placed perpendicular the viewing surface. To provide a greater contrast in the meniscus, an EL backlighting sheet was used to backlight the tanks. These images and video are then digitized, passed through NASA's mini-tracker software, and compared to a theory published my M. M. Weislogel, "Fluid Interface Phenomena in a Low-Gravity Environment: Recent Results from Drop Tower Experimentation." By focusing on a lower portion of the meniscus and using longer periods of reduced gravity, this experiment may confirm that a stationary point exists on the fluid surface. This information will enable better designing of propellant management devices, especially satellite propellant refilling and gas venting. Also, biological and material processing systems in reduced gravity environments will benefit from this data.
A new contrast-assisted method in microcirculation volumetric flow assessment
NASA Astrophysics Data System (ADS)
Lu, Sheng-Yi; Chen, Yung-Sheng; Yeh, Chih-Kuang
2007-03-01
Microcirculation volumetric flow rate is a significant index in diseases diagnosis and treatment such as diabetes and cancer. In this study, we propose an integrated algorithm to assess microcirculation volumetric flow rate including estimation of blood perfused area and corresponding flow velocity maps based on high frequency destruction/contrast replenishment imaging technique. The perfused area indicates the blood flow regions including capillaries, arterioles and venules. Due to the echo variance changes between ultrasonic contrast agents (UCAs) pre- and post-destruction two images, the perfused area can be estimated by the correlation-based approach. The flow velocity distribution within the perfused area can be estimated by refilling time-intensity curves (TICs) after UCAs destruction. Most studies introduced the rising exponential model proposed by Wei (1998) to fit the TICs. Nevertheless, we found the TICs profile has a great resemblance to sigmoid function in simulations and in vitro experiments results. Good fitting correlation reveals that sigmoid model was more close to actual fact in describing destruction/contrast replenishment phenomenon. We derived that the saddle point of sigmoid model is proportional to blood flow velocity. A strong linear relationship (R = 0.97) between the actual flow velocities (0.4-2.1 mm/s) and the estimated saddle constants was found in M-mode and B-mode flow phantom experiments. Potential applications of this technique include high-resolution volumetric flow rate assessment in small animal tumor and the evaluation of superficial vasculature in clinical studies.
Scagnelli, Alyssa M; Walton, Stuart A; Liu, Chin-Chi; Acierno, Mark J
2018-05-01
CASE DESCRIPTION A 9-year-old 8.3-kg (18.3-lb) neutered male Miniature Schnauzer was referred for diagnosis and treatment of a sudden onset of lethargy, anorexia, vomiting, and pallor. CLINICAL FINDINGS On physical examination, the dog was lethargic with pale mucous membranes and a capillary refill time ≥ 2 seconds. Skin and sclera were mildly icteric. Signs of pain were elicited during abdominal palpation, and an enlarged spleen was noted. Results of agglutination testing and cytologic findings were consistent with immune-mediated hemolytic anemia (IMHA). No contributing factors for development of IMHA were identified. TREATMENT AND OUTCOME Initial treatment included management with immunosuppressant medications. Three packed RBC transfusions were administered, but clinical signs continued to progress. Therefore, therapeutic plasma exchange (TPE) was performed 5 and 9 days after admission. Following each TPE procedure, the dog had an appreciable clinical improvement and decrease in RBC autoagglutination, and the Hct stabilized. Serum IgG and IgM concentrations were measured during and after both TPE procedures. Despite anticoagulative treatment, the dog developed a thrombus in the splenic vein, necessitating a splenectomy. CLINICAL RELEVANCE The decrease and rebound in serum IgG and IgM concentrations following TPE provided evidence that TPE may have the same immunomodulatory effects in dogs as have been proposed to occur in people. Further, findings suggested that TPE may be a useful alternative in dogs with refractory IMHA when traditional treatments fail.
Reversible Microvascular Hyporeactivity to Acetylcholine During Diabetic Ketoacidosis.
Joffre, Jérémie; Bourcier, Simon; Hariri, Geoffroy; Miailhe, Arnaud-Felix; Bigé, Naike; Dumas, Guillaume; Dubée, Vincent; Boelle, Pierre-Yves; Abdallah, Idriss; Baudel, Jean-Luc; Guidet, Bertrand; Maury, Eric; Ait-Oufella, Hafid
2018-05-18
Metabolic acidosis is commonly observed in critically ill patients. Experimental studies suggested that acidosis by itself could impair vascular function, but this has been poorly investigated in human. Prospective observational study. Medical ICU in a tertiary teaching hospital. To assess the relationship between metabolic acidosis severity and microvascular reactivity, we included adult diabetic patients admitted in ICU for ketoacidosis. Microvascular response to acetylcholine iontophoresis was measured at admission (baseline) and after correction of metabolic acidosis (24 hr). None. Thirty-nine patients with diabetic ketoacidosis were included (68% male), with a median age of 43 (31-57) years. At admission, microvascular reactivity negatively correlated with acidosis severity (R = -0.53; p < 0.001). Microvascular response was strongly depressed at pH less than 7.20 (area under the curve, 1,779 [740-3,079] vs 12,944 [4,874-21,596] at pH > 7.20; p < 0.0001). In addition, acidosis severity was significantly correlated with capillary refill time (R = 0.50; p = 0.02). At H24, after rehydration and insulin infusion, clinical and biological disorders were fully corrected. After acidosis correction, microvascular reactivity increased more in patients with severe baseline acidosis (pH < 7.20) than in those with mild baseline acidosis (area under the curve, +453% [213%-1,470%] vs +121% [79%-312%]; p < 0.01). We identified an alteration of microvascular reactivity during metabolic acidosis in critically ill patients with diabetic ketoacidosis. Microvascular hyporeactivity recovered after acidosis correction.
Buffington, C A; Knight, D A; Kohn, C W; Madigan, J E; Scaman, P A
1992-10-01
The effects of 2 liquid formula diets differing in protein source were evaluated in orphan foals. The response of 7 foals fed a diet containing casein as the protein source, and 6 foals fed a diet containing a combination of whey and casein, was compared with the response in a reference group of 8 mare-raised foals. Orphaned foals were fed 150 kcal/kg of body weight/d, divided into 6 equal feedings of 25 kcal/kg. Formula intake was comparable among the experimental groups, and foals fed the liquid formula diet grew as well as mare-raised foals. There was no difference among groups in mean daily body weight gain, wither height, heart girth, body temperature, pulse, respiration rate, capillary refill time, or skin tenting. Insulin and blood glucose concentrations increased in both groups of foals fed formula diets, returning to prefeeding values within 4 hours. Differences among groups were found for serum alkaline phosphatase, alanine transaminase, cholesterol, creatinine, and glucose values; all other serum chemical values were comparable among groups. Plasma amino acid determinations revealed that arginine and ornithine were significantly lower in foals in both experimental groups than in reference foals, suggesting that arginine may have been the limiting amino acid in these diets. Diarrhea developed in foals in all treatment groups, but in most cases was self-limiting. These results suggest that the protein source of liquid formula diets may be less important in foals than in infants.
Technology needs for the development of the accommodative intraocular lens
NASA Astrophysics Data System (ADS)
Nishi, Okihiro
2010-02-01
Refilling the lens capsule while preserving capsular integrity offers the potential to restore ocular accommodation. There are two persisting problems in capsular bag refilling for possible clinical application: Leakage of the injectable material through the capsular opening and capsular opacification. Numerous attempts for solving these cardinal problems have not been proven to be clinically applicable. Recently, we developed a novel capsular bag refilling procedure using a novel accommodative intraocular lens that serves as an optic as well as a plug for sealing the capsular opening. The procedure and the results of monkey experiments will be presented.
Counterfeit Electronic Cigarette Products with Mislabeled Nicotine Concentrations.
Omaiye, Esther E; Cordova, Iliana; Davis, Barbara; Talbot, Prue
2017-07-01
We compared nicotine concentrations in one brand of refill fluids that were purchased in 4 countries and labeled 0 mg of nicotine/mL. We then identified counterfeit e-cigarette products from these countries. Overall, 125 e-cigarette refill fluids were purchased in Nigeria, the United States (US), England, and China. Nicotine concentrations were measured using high performance liquid chromatography and compared to labeled concentrations. Refill fluids were examined to identify physical differences and grouped into authentic and counterfeit products. Whereas nicotine was in 51.7% (15/29) of the Nigerian, 3.7% (1/27) of the Chinese and 1.6% (1/61) of the American refill fluids (range = 0.4 - 20.4 mg/mL), 8 British products did not contain nicotine. Products from China, the US, and Nigeria with trace amounts of nicotine (0.4 to 0.6 mg/mL) were authentic; however, all products from Nigeria with more than 3.7 mg/mL were counterfeit. We introduce 2 novel issues in the e-cigarette industry, the production of counterfeit refill fluids under a brandjacked label and inclusion of nicotine in 81.3% of the counterfeit products labeled 0 mg/mL. This study emphasizes the need for better control and monitoring of nicotine containing products and sales outlets.
Analytical and toxicological evaluation of flavor chemicals in electronic cigarette refill fluids.
Behar, Rachel Z; Luo, Wentai; McWhirter, Kevin J; Pankow, James F; Talbot, Prue
2018-05-29
Thousands of electronic cigarette refill fluids are commercially available. The concentrations of nicotine and the solvents, but not the flavor chemicals, are often disclosed on product labels. The purpose of this study was to identify and quantify flavor chemicals in 39 commercial refill fluids that were previously evaluated for toxicity. Twelve flavor chemicals were identified with concentrations ≥1 mg/ml: cinnamaldehyde, menthol, benzyl alcohol, vanillin, eugenol, p-anisaldehyde, ethyl cinnamate, maltol, ethyl maltol, triacetin, benzaldehyde, and menthone. Transfer of these flavor chemicals into aerosols made at 3V and 5V was efficient (mean transfer = 98%). We produced lab-made refill fluids containing authentic standards of each flavor chemical and analyzed the toxicity of their aerosols produced at 3V and 5V using a tank Box Mod device. Over 50% of the refill fluids in our sample contained high concentrations of flavor chemicals that transferred efficiently to aerosols at concentrations that produce cytotoxicity. When tested with two types of human lung cells, the aerosols made at 5V were generally more toxic than those made at 3V. These data will be valuable for consumers, physicians, public health officials, and regulatory agencies when discussing potential health concerns relating to flavor chemicals in electronic cigarette products.
SOURCE CHARACTERIZATION OF AIR FRESHENERS
The paper discusses research in which five air fresheners of two styles were analyzed for their constituent volatile organic compounds. Both styles were refills to be inserted into heated electric plug-in units; one refill released the fragrance from a gel pack insert and the oth...
Andreski, Michael; Myers, Megan; Gainer, Kate; Pudlo, Anthony
Determine the effects of an 18-month pilot project using tech-check-tech in 7 community pharmacies on 1) rate of dispensing errors not identified during refill prescription final product verification; 2) pharmacist workday task composition; and 3) amount of patient care services provided and the reimbursement status of those services. Pretest-posttest quasi-experimental study where baseline and study periods were compared. Pharmacists and pharmacy technicians in 7 community pharmacies in Iowa. The outcome measures were 1) percentage of technician verified refill prescriptions where dispensing errors were not identified on final product verification; 2) percentage of time spent by pharmacists in dispensing, management, patient care, practice development, and other activities; 3) the number of pharmacist patient care services provided per pharmacist hours worked; and 4) percentage of time that technician product verification was used. There was no significant difference in overall errors (0.2729% vs. 0.5124%, P = 0.513), patient safety errors (0.0525% vs. 0.0651%, P = 0.837), or administrative errors (0.2204% vs. 0.4784%, P = 0.411). Pharmacist's time in dispensing significantly decreased (67.3% vs. 49.06%, P = 0.005), and time in direct patient care (19.96% vs. 34.72%, P = 0.003), increased significantly. Time in other activities did not significantly change. Reimbursable services per pharmacist hour (0.11 vs. 0.30, P = 0.129), did not significantly change. Non-reimbursable services increased significantly (2.77 vs. 4.80, P = 0.042). Total services significantly increased (2.88 vs. 5.16, P = 0.044). Pharmacy technician product verification of refill prescriptions preserved dispensing safety while significantly increasing the time spent in delivery of pharmacist provided patient care services. The total number of pharmacist services provided per hour also increased significantly, driven primarily by a significant increase in the number of non-reimbursed services. This was mostly likely due to the increased time available to provide patient care. Reimbursed services per hour did not increase significantly mostly likely due to lack of payers. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Shirai, Atsushi; Masuda, Sunao
2013-01-01
The authors have previously presented a mathematical model to predict transit time of a neutrophil through an alveolar capillary segment which was modeled as an axisymmetric arc-shaped constriction settled in a cylindrical straight pipe to investigate the influence of entrance curvature of a capillary on passage of the cell. The axially asymmetric cross section of a capillary also influences the transit time because it requires three-dimensional deformation of a cell when it passes through the capillary and could lead to plasma leakage between the cell surface and the capillary wall. In this study, a rectangular channel was introduced, the side walls of which were moderately constricted, as a representative of axially asymmetric capillaries. Dependence of transit time of a neutrophil passing through the constriction on the constriction geometry, i.e., channel height, throat width and curvature radius of the constriction, was numerically investigated, the transit time being compared with that through the axisymmetric model. It was found that the transit time is dominated by the throat hydraulic diameter and curvature radius of the constriction and that the throat aspect ratio little affects the transit time with a certain limitation, indicating that if an appropriate curvature radius is chosen, such a rectangular channel model can be substituted for an axisymmetric capillary model having the same throat hydraulic diameter in terms of the transit time by choosing an appropriate curvature radius. Thus, microchannels fabricated by the photolithography technique, whose cross section is generally rectangular, are expected to be applicable to in vitro model experiments of neutrophil retention and passage in the alveolar capillaries. PMID:23527190
Hall, Stephen H.
1996-01-01
The present invention is a reference half-cell electrode wherein intermingling of test fluid with reference fluid does not affect the performance of the reference half-cell over a long time. This intermingling reference half-cell may be used as a single or double junction submersible or surface reference electrode. The intermingling reference half-cell relies on a capillary tube having a first end open to reference fluid and a second end open to test fluid wherein the small diameter of the capillary tube limits free motion of fluid within the capillary to diffusion. The electrode is placed near the first end of the capillary in contact with the reference fluid. The method of operation of the present invention begins with filling the capillary tube with a reference solution. After closing the first end of the capillary, the capillary tube may be fully submerged or partially submerged with the second open end inserted into test fluid. Since the electrode is placed near the first end of the capillary, and since the test fluid may intermingle with the reference fluid through the second open end only by diffusion, this intermingling capillary reference half-cell provides a stable voltage potential for long time periods.
Hall, S.H.
1996-02-13
The present invention is a reference half-cell electrode wherein intermingling of test fluid with reference fluid does not affect the performance of the reference half-cell over a long time. This intermingling reference half-cell may be used as a single or double junction submersible or surface reference electrode. The intermingling reference half-cell relies on a capillary tube having a first end open to reference fluid and a second end open to test fluid wherein the small diameter of the capillary tube limits free motion of fluid within the capillary to diffusion. The electrode is placed near the first end of the capillary in contact with the reference fluid. The method of operation of the present invention begins with filling the capillary tube with a reference solution. After closing the first end of the capillary, the capillary tube may be fully submerged or partially submerged with the second open end inserted into test fluid. Since the electrode is placed near the first end of the capillary, and since the test fluid may intermingle with the reference fluid through the second open end only by diffusion, this intermingling capillary reference half-cell provides a stable voltage potential for long time periods. 11 figs.
Code of Federal Regulations, 2010 CFR
2010-01-01
... percent of all lighters sold are pocket-sized disposable butane models; of the remaining 5 percent, most are pocket refillable butane models. A small proportion of refillables is comprised of pocket liquid-fuel models; still smaller proportions are represented by table lighters and by “novelty” lighters...
75 FR 6350 - Post Allowance and Refiling
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-09
... DEPARTMENT OF COMMERCE Patent and Trademark Office Post Allowance and Refiling ACTION: Proposed collection; comment request. SUMMARY: The United States Patent and Trademark Office (USPTO), as part of its... Officer, Office of the Chief Information Officer, United States Patent and Trademark Office, P.O. Box 1450...
Analysis of refill liquids for electronic cigarettes.
Etter, Jean-François; Zäther, Eva; Svensson, Sofie
2013-09-01
To assess levels of nicotine, nicotine degradation products and some specific impurities in commercial refill liquids for electronic cigarettes. We analyzed 20 models of 10 of the most popular brands of refill liquids, using gas and liquid chromatography. We assessed nicotine content, content of the known nicotine degradation products and impurities, and presence of ethylene glycol and diethylene glycol. The nicotine content in the bottles corresponded closely to the labels on the bottles. The levels of nicotine degradation products represented 0-4.4% of those for nicotine, but for most samples the level was 1-2%. Cis-N-oxide, trans-N-oxide, myosmine, anatabine and anabasine were the most common additional compounds found. Neither ethylene glycol nor diethylene glycol were detected. The nicotine content of electronic cigarette refill bottles is close to what is stated on the label. Impurities are detectable in several brands above the level set for nicotine products in the European Pharmacopoeia, but below the level where they would be likely to cause harm. © 2013 Society for the Study of Addiction.
Sattler, Elisabeth Lilian Pia; Lee, Jung Sun; Bhargava, Vibha
2014-01-01
Little is known about diabetes management among low-income older Americans. This study used statewide self-administered survey and Medicare claims data to examine the relationships of food insecurity and medication (re)fill adherence in a sample of Medicare Part D beneficiaries with type 2 diabetes in need of food assistance in Georgia in 2008 (n = 243, mean age 74.2 ± 7.8 years, 27.2% African American, 77.4% female). (Re)fill adherence to oral hypoglycemics was measured as Proportion of Days Covered. Food insecurity was assessed using a six-item validated standard measure. About 54% of the sample were food insecure. About 28% of the diabetic sample did not (re)fill any diabetes medication and over 80% had at least one diabetes complication. Food insecure participants showed comparable (re)fill adherence to food secure participants. However, 57% of food insecure participants were nonadherent to oral hypoglycemics. Underlying basic needs must be addressed to improve diabetes management in this population.
NASA Astrophysics Data System (ADS)
Li, Zhengwei; Gao, Shuangsheng; Ji, Shude; Yue, Yumei; Chai, Peng
2016-04-01
Refill friction stir spot welding (RFSSW) was successfully used to weld alclad 2024 aluminum alloy with different thicknesses. Effects of tool rotational speed on the weld formation, microstructure, and mechanical properties of the RFSSW welds were mainly discussed. Results show that keyhole is successfully refilled and welding defects such as flash, annular groove, and material adhesion can be observed. A bright contrast bonding ligament is found embedded in the weld and it is thicker in the center. Defects of hook, void, lack of mixing, and incomplete refilling can be found at the thermo-mechanically affected zone/stir zone (TMAZ/SZ) interface, which can be attributed to weak metallurgical bonding effect. With increasing the tool rotational speed, thickness of the bonding ligament decreases, grains in the SZ coarsen, hardness of the SZ decreases, and lap shear load of the welds decreases. When changing the rotating speed, impact strength shows rather complicated variation trend.
Device to improve detection in electro-chromatography
Garguilo, Michael G.; Paul, Phillip H.; Rakestraw, David J.
2000-01-01
Apparatus and method for improving the resolution of non-pressure driven capillary chromatographic systems, and particularly for capillary electrochromatography (CEC) systems. By reducing the cross-sectional area of a packed capillary column by means of a second open capillary contiguous with the outlet end of a packed capillary column, where the packed capillary column has a cross sectional area of between about 2 and 5 times that of the open capillary column, the phenomenon of band broadening in the transition region between the open capillary and the packed capillary column, where the individual components of the mixture are analyzed, can be eliminated, thereby providing for a significant improvement in resolution and more accurate detection and analysis.
Device to improve detection in electro-chromatography
Garguilo, Michael G.; Paul, Phillip H.; Rakestraw, David J.
2002-01-01
Apparatus and method for improving the resolution of non-pressure driven capillary chromatographic systems, and particularly for capillary electrochromatography (CEC) systems. By reducing the cross-sectional area of a packed capillary column by means of a second open capillary contiguous with the outlet end of a packed capillary column, where the packed capillary column has a cross sectional area of between about 2 and 5 times that of the open capillary column, the phenomenon of band broadening in the transition region between the open capillary and the packed capillary column, where the individual components of the mixture are analyzed, can be eliminated, thereby providing for a significant improvement in resolution and more accurate detection and analysis.
Best Practices for Intrathecal Baclofen Therapy: Dosing and Long-Term Management.
Boster, Aaron L; Adair, Roy L; Gooch, Judith L; Nelson, Mary Elizabeth S; Toomer, Andrea; Urquidez, Joe; Saulino, Michael
2016-08-01
Intrathecal baclofen (ITB) therapy aims to reduce spasticity and provide functional control. An expert panel consulted on best practices. Pump fill and drug delivery can be started intraoperatively, with monitoring for at least eight hours. Initiate with the 500 mcg/mL concentration. The starting daily dose should be twice the effective bolus screening dose, or the screening dose if the patient had a prolonged response (greater than eight hours) or negative reactions. Oral antispasmodics can be weaned, one drug at a time beginning with oral baclofen after ITB begins. Assessment should occur within 24 hours of a dose change. For adults, daily dose increases may be 5% to 15% once every 24 hours for cerebral-origin spasticity and 10% to 30% once every 24 hours for spinal-origin spasticity. Daily dose increases can be 5% to 15% once every 24 hours for children. Inpatients should be assessed at least every 24 hours and receive rehabilitation. Step dosing can be used for outpatients who cannot return daily. Dosing options include simple continuous dosing, variable 24-hour flex dosing, or regularly scheduled boluses. Patients/caregivers should understand the care plan, responsibilities, and possible side-effects. Low-reservoir alarm dates and refill schedules should be written down, along with emergency contact information. A higher concentration at refill can extend refill intervals, and a bridge bolus must be programmed. Time changes may affect flex dosing. Pump replacement should be scheduled at least three months in advance. ITB dosing is multistep and individualized. © 2016 International Neuromodulation Society.
Waste prevention in liquid detergent distribution: a comparison based on life cycle assessment.
Nessi, Simone; Rigamonti, Lucia; Grosso, Mario
2014-11-15
The distribution of liquid detergents through self-dispensing systems has been adopted in some Italian retail stores over the last few years. By enabling the consumer to refill several times the same container, it is proposed as a less waste-generating and more environmentally friendly alternative to the traditional distribution with single-use plastic containers. For this reason, its implementation is encouraged by the national waste prevention programme recently adopted in Italy. In order to assess such claims, a life cycle assessment was carried out to evaluate whether detergent distribution through self-dispensing systems actually allows to achieve the expected reduction in waste generation and environmental impacts. The focus was on the distribution within the large-scale retail trade and on the categories of laundry detergents, fabric softeners and hand dishwashing detergents. For each of them, a set of baseline single-use scenarios were compared with two alternative waste prevention scenarios, where the detergent is distributed through self-dispensing systems. Beyond waste generation, also the Cumulative Energy Demand and thirteen midpoint-level potential impact indicators were calculated for the comparison. Results showed that a reduction in waste generation up to 98% can be achieved, depending on the category of detergent, on the baseline scenario of comparison and on the number of times the refillable container is used. A progressive reduction in the energy demand and in most of the potential impacts was also observed, starting from a minimum number of uses of the refillable container. Copyright © 2014 Elsevier B.V. All rights reserved.
Wojcik, Roza; Vannatta, Michael
2010-01-01
Diagonal capillary electrophoresis is a form of two-dimensional capillary electrophoresis that employs identical separation modes in each dimension. The distal end of the first capillary incorporates an enzyme-based microreactor. Analytes that are not modified by the reactor will have identical migration times in the two capillaries and will generate spots that fall on the diagonal in a reconstructed two-dimensional electropherogram. Analytes that undergo enzymatic modification in the reactor will have a different migration time in the second capillary and will generate spots that fall off the diagonal in the electropherogram. We demonstrate the system with immobilized alkaline phosphatase to monitor the phosphorylation status of a mixture of peptides. This enzyme-based diagonal capillary electrophoresis assay appears to be generalizable; any post-translational modification can be detected as long as an immobilized enzyme is available that reacts with the modification under electrophoretic conditions. PMID:20099889
Belcaro, G; Rulo, A; Renton, S
1992-01-01
To evaluate capillary filtration a group of normal subjects and two groups of subjects with venous incompetence (50 with deep and 50 with superficial incompetence) were studied with the vacuum suction chamber (VSC) device applied onto the internal perimalleolar region. This method was compared with straingauge plethysmography rate of ankle swelling (RAS). By the VSC the time taken for the weal to disappear (VSC time) was considered indicative of capillary filtration. The values obtained with the two methods were well related (r < 0.742) and there was a good separation between patients and normals. The separation between the two groups of patients was significantly better (p < 0.05) with the VSC time. In conclusion VSC time is a good indication of capillary filtration in comparison with straingauge plethysmography RAS. It may be used to assess variations in capillary filtration in venous hypertension and possibly to follow up the effects of treatments.
NASA Astrophysics Data System (ADS)
Chatterjee, K.; Schunk, R. W.
2017-12-01
The refilling of the plasmasphere following a geomagnetic storm remains one of the longstanding problems in the area of ionosphere-magnetosphere coupling. Both diffusion and hydrodynamic approximations have been adopted for the modeling and solution of this problem. The diffusion approximation neglects the nonlinear inertial term in the momentum equation and so this approximation is not rigorously valid immediately after the storm. Over the last few years, we have developed a hydrodynamic refilling model using the flux-corrected transport method, a numerical method that is extremely well suited to handling nonlinear problems with shocks and discontinuities. The plasma transport equations are solved along 1D closed magnetic field lines that connect conjugate ionospheres and the model currently includes three ion (H+, O+, He+) and two neutral (O, H) species. In this work, each ion species under consideration has been modeled as two separate streams emanating from the conjugate hemispheres and the model correctly predicts supersonic ion speeds and the presence of high levels of Helium during the early hours of refilling. The ultimate objective of this research is the development of a 3D model for the plasmasphere refilling problem and with additional development, the same methodology can potentially be applied to the study of other complex space plasma coupling problems in closed flux tube geometries. Index Terms: 2447 Modeling and forecasting [IONOSPHERE] 2753 Numerical modeling [MAGNETOSPHERIC PHYSICS] 7959 Models [SPACE WEATHER
Sampling Error in a Particulate Mixture: An Analytical Chemistry Experiment.
ERIC Educational Resources Information Center
Kratochvil, Byron
1980-01-01
Presents an undergraduate experiment demonstrating sampling error. Selected as the sampling system is a mixture of potassium hydrogen phthalate and sucrose; using a self-zeroing, automatically refillable buret to minimize titration time of multiple samples and employing a dilute back-titrant to obtain high end-point precision. (CS)
75 FR 29782 - Proposed Collection, Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-27
... comments concerning the proposed extension of the Annual Refiling Survey (ARS). A copy of the proposed... verified and updated. For this purpose, the Annual Refiling Survey (ARS) is used in conjunction with the UI tax reporting system in each State. The information collected on the ARS is used to review the...
78 FR 44160 - Proposed Collection, Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-23
... comments concerning the proposed revision of the Annual Refiling Survey (ARS). A copy of the proposed..., the Annual Refiling Survey (ARS) is used in conjunction with the UI tax reporting system in each State. The information collected on the ARS is used to review the existing industry code assigned to each...
40 CFR 156.156 - Residue removal instructions for refillable containers.
Code of Federal Regulations, 2011 CFR
2011-07-01
... adequate to protect human health and the environment. (2) Subject to meeting the standard in paragraph (b... (CONTINUED) PESTICIDE PROGRAMS LABELING REQUIREMENTS FOR PESTICIDES AND DEVICES Container Labeling § 156.156 Residue removal instructions for refillable containers. The label of each pesticide product packaged in a...
40 CFR 156.156 - Residue removal instructions for refillable containers.
Code of Federal Regulations, 2014 CFR
2014-07-01
... adequate to protect human health and the environment. (2) Subject to meeting the standard in paragraph (b... (CONTINUED) PESTICIDE PROGRAMS LABELING REQUIREMENTS FOR PESTICIDES AND DEVICES Container Labeling § 156.156 Residue removal instructions for refillable containers. The label of each pesticide product packaged in a...
40 CFR 156.156 - Residue removal instructions for refillable containers.
Code of Federal Regulations, 2013 CFR
2013-07-01
... adequate to protect human health and the environment. (2) Subject to meeting the standard in paragraph (b... (CONTINUED) PESTICIDE PROGRAMS LABELING REQUIREMENTS FOR PESTICIDES AND DEVICES Container Labeling § 156.156 Residue removal instructions for refillable containers. The label of each pesticide product packaged in a...
40 CFR 156.156 - Residue removal instructions for refillable containers.
Code of Federal Regulations, 2012 CFR
2012-07-01
... adequate to protect human health and the environment. (2) Subject to meeting the standard in paragraph (b... (CONTINUED) PESTICIDE PROGRAMS LABELING REQUIREMENTS FOR PESTICIDES AND DEVICES Container Labeling § 156.156 Residue removal instructions for refillable containers. The label of each pesticide product packaged in a...
40 CFR 156.156 - Residue removal instructions for refillable containers.
Code of Federal Regulations, 2010 CFR
2010-07-01
... adequate to protect human health and the environment. (2) Subject to meeting the standard in paragraph (b... (CONTINUED) PESTICIDE PROGRAMS LABELING REQUIREMENTS FOR PESTICIDES AND DEVICES Container Labeling § 156.156 Residue removal instructions for refillable containers. The label of each pesticide product packaged in a...
41 CFR 101-25.107 - Guidelines for requisitioning and proper use of consumable or low cost items.
Code of Federal Regulations, 2011 CFR
2011-07-01
... needs. Attache cases, Ball point pens and refills, Brief cases, Binders, Carbon paper, Dictionaries, Felt tip markers, Felt tip pens and refills, File folders, Letterex, Letter openers, Pads (paper), Paper clips, Pencils, Pencil sharpeners, Portfolios (leather, plastic, and writing pads), Rubber bands...
41 CFR 101-25.107 - Guidelines for requisitioning and proper use of consumable or low cost items.
Code of Federal Regulations, 2012 CFR
2012-07-01
... needs. Attache cases, Ball point pens and refills, Brief cases, Binders, Carbon paper, Dictionaries, Felt tip markers, Felt tip pens and refills, File folders, Letterex, Letter openers, Pads (paper), Paper clips, Pencils, Pencil sharpeners, Portfolios (leather, plastic, and writing pads), Rubber bands...
41 CFR 101-25.107 - Guidelines for requisitioning and proper use of consumable or low cost items.
Code of Federal Regulations, 2014 CFR
2014-07-01
... needs. Attache cases, Ball point pens and refills, Brief cases, Binders, Carbon paper, Dictionaries, Felt tip markers, Felt tip pens and refills, File folders, Letterex, Letter openers, Pads (paper), Paper clips, Pencils, Pencil sharpeners, Portfolios (leather, plastic, and writing pads), Rubber bands...
41 CFR 101-25.107 - Guidelines for requisitioning and proper use of consumable or low cost items.
Code of Federal Regulations, 2013 CFR
2013-07-01
... needs. Attache cases, Ball point pens and refills, Brief cases, Binders, Carbon paper, Dictionaries, Felt tip markers, Felt tip pens and refills, File folders, Letterex, Letter openers, Pads (paper), Paper clips, Pencils, Pencil sharpeners, Portfolios (leather, plastic, and writing pads), Rubber bands...
NASA Technical Reports Server (NTRS)
Poberezhskiy, Ilya Y.; Meras, Patrick; Chang, Daniel H.; Spiers, Gary D.
2007-01-01
A simple method for evacuating, refilling and connectorizing hollow-core photonic crystal fiber for use asgas reference cell is proposed and demonstrated. It relies on torch-sealing a quartz filling tube connected to amechanical splice between regular and hollow-core fibers.
[Examples for using capillary gas chromatography with wide bore columns in occupational health].
Frank, H; Senf, L; Welsch, T
1990-12-01
Wide bore capillary columns (0.4-0.75 mm ID) can be easily and inexpensively installed in packed column GCs. The analytical advantages cause an expanding market for such capillaries and interconverting hardware kits. It is illustrated with some examples that often individual exposition levels can be determined exactly only by using capillary columns: ethylbenzene may be separated from the C8-isomers also in complex mixtures, the marker PBN for rubber smoke expositions can be determined with 30 min sampling time, the detection sensitivity of the FID is sufficient also for chlorinated pesticides and the analyses of high-boiling compounds profit by the high phase ratio of wide bore capillary columns. A single capillary column substitutes a variety of different packed columns, so saving time and money and protecting the analyst from failures and frustrating compromises.
A Zero Dimensional Time-Dependent Model of High-Pressure Ablative Capillary Discharge (Preprint)
2008-06-01
comprehensive model of capillary discharge is important to understand the physics and engineering aspects of the capillary discharge thruster. A schematic...investigators since the mid-1980s see 1-11 and references therein, satisfy both of these conditions well. These studies investigated the dynamics of high...is a comprehensive description of the radiative heat transfer in the capillary discharge. It is worth noting that in other types of capillary
Shirai, Atsushi; Fujita, Ryo; Hayase, Toshiyuki
2007-01-01
The concentration of neutrophils in the pulmonary microvasculature is higher than in large systemic vessels. It is thought that the high concentration of neutrophils facilitates their effective recruitment to sites of inflammation. Thus, in order to understand the role of neutrophils in the immune system, it is important to clarify their flow characteristics in the pulmonary microvasculature. In a previous study, we developed a model to simulate the flow of neutrophils in a capillary network, in which the cells were modeled as spheres of a Maxwell material with a cortical tension and the capillary segments were modeled as arc-shaped constrictions in straight pipes. In the present paper, the flow of neutrophils in a simplified alveolar capillary network model is investigated for various constriction shapes and cell stiffnesses. Finally, it is shown that both the coefficient of variation of the transit time of the cells, which is the standard deviation divided by the mean transit time, and the mean transit time increase as the capillary segments become steep or tight, or when the cells become hard. The mean value of the transit time exceeds the median for all of the conditions that occur in real lungs, although the difference between them is small.
40 CFR 165.65 - Registrants who distribute or sell pesticide products in refillable containers.
Code of Federal Regulations, 2010 CFR
2010-07-01
... formula that is required under FIFRA section 3. (c) What information must I develop? For each pesticide... its confidential statement of formula that is required under FIFRA section 3. (ii) If the refilling..., metal fatigue, damaged threads or closures, or other significant defects. (iii) The container has cracks...
40 CFR 165.70 - Refillers who are not registrants.
Code of Federal Regulations, 2010 CFR
2010-07-01
... site of a user who intends to use or apply the product. (3) The registrant has entered into a written... changes except the addition of an appropriate net contents statement and the refillers EPA establishment... with the requirements of part 156 of this chapter. In particular, you must ensure that the net contents...
Method and apparatus for filling thermal insulating systems
Arasteh, Dariush K.
1992-01-01
A method for filling insulated glazing units is disclosed. The method utilizes a vacuum chamber in which the insulated glazing units are placed. The insulated glazing units and vacuum chamber are evacuated simultaneously. The units are then refilled with a low conductance gas such as Krypton while the chamber is simultaneously refilled with air.
26 CFR 301.6323(g)-1 - Refiling of notice of tax lien.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 26 Internal Revenue 18 2014-04-01 2014-04-01 false Refiling of notice of tax lien. 301.6323(g)-1 Section 301.6323(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) PROCEDURE AND ADMINISTRATION PROCEDURE AND ADMINISTRATION Collection General Provisions § 301.6323(g)-1...
26 CFR 301.6323(g)-1 - Refiling of notice of tax lien.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 26 Internal Revenue 18 2013-04-01 2013-04-01 false Refiling of notice of tax lien. 301.6323(g)-1 Section 301.6323(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) PROCEDURE AND ADMINISTRATION PROCEDURE AND ADMINISTRATION Collection General Provisions § 301.6323(g)-1...
26 CFR 301.6323(g)-1 - Refiling of notice of tax lien.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 18 2010-04-01 2010-04-01 false Refiling of notice of tax lien. 301.6323(g)-1 Section 301.6323(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) PROCEDURE AND ADMINISTRATION PROCEDURE AND ADMINISTRATION Collection General Provisions § 301.6323(g)-1...
26 CFR 301.6323(g)-1 - Refiling of notice of tax lien.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 26 Internal Revenue 18 2012-04-01 2012-04-01 false Refiling of notice of tax lien. 301.6323(g)-1 Section 301.6323(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) PROCEDURE AND ADMINISTRATION PROCEDURE AND ADMINISTRATION Collection General Provisions § 301.6323(g)-1...
26 CFR 301.6323(g)-1 - Refiling of notice of tax lien.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 26 Internal Revenue 18 2011-04-01 2011-04-01 false Refiling of notice of tax lien. 301.6323(g)-1 Section 301.6323(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) PROCEDURE AND ADMINISTRATION PROCEDURE AND ADMINISTRATION Collection General Provisions § 301.6323(g)-1...
Microstructure and Mechanical Properties of 316L Stainless Steel Filling Friction Stir-Welded Joints
NASA Astrophysics Data System (ADS)
Zhou, L.; Nakata, K.; Tsumura, T.; Fujii, H.; Ikeuchi, K.; Michishita, Y.; Fujiya, Y.; Morimoto, M.
2014-10-01
Keyhole left at 316L stainless steel friction stir welding/friction stir processing seam was repaired by filling friction stir welding (FFSW). Both metallurgical and mechanical bonding characteristics were obtained by the combined plastic deformation and flow between the consumable filling tool and the wall of the keyhole. Two ways based on the original conical and modified spherical keyholes, together with corresponding filling tools and process parameters were investigated. Microstructure and mechanical properties of 316L stainless steel FFSW joints were evaluated. The results showed that void defects existed at the bottom of the refilled original conical keyhole, while excellent bonding interface was obtained on the refilled modified spherical keyhole. The FFSW joint with defect-free interface obtained on the modified spherical keyhole fractured at the base metal side during the tensile test due to microstructural refinement and hardness increase in the refilled keyhole. Moreover, no σ phase but few Cr carbides were formed in the refilled zone, which would not result in obvious corrosion resistance degradation of 316L stainless steel.
Fukuoka, Masato; Sugimoto, Takaki; Okita, Yutaka
2003-10-01
The purpose of this study was to evaluate lower extremity venous function in patients with chronic venous insufficiency, with foot venous pressure (FVP) measurements and air plethysmography (APG). Eighty-five limbs of 63 patients with a history of chronic venous insufficiency (CVI) from 1995 to 1999 were studied. FVP parameters studied included ambulatory venous pressure (AVP), percent decrease in FVP with manual calf compression (%drop), ratio of increase in FVP over 4 seconds after release of compression (4SR%), and time to 90% recovery of FVP were measured. APG parameters studied included functional venous volume, 90% refilling time (VFT90), venous filling index, ejection fraction, and residual volume fraction. Venous filling index and 90% refilling time were significantly decreased in limbs with stasis syndrome compared with the control group. AVP, %drop, and 4SR% also showed significantly decrease in limbs with stasis syndrome compared with those without it. AVP, %drop, and 4SR% were significantly different for the primary group compared with the secondary group, whereas no differences were found with regard to any APG parameter. APG enables prediction of the presence of CVI, whereas FVP measurements are more useful for evaluation of clinical severity of CVI.
NASA Astrophysics Data System (ADS)
Liasi, Faezeh Talebi; Samatham, Ravikant; Jacques, Steven L.
2017-11-01
Assessing the metabolic activity of a tissue, whether normal, damaged, aged, or pathologic, is useful for diagnosis and evaluating the effects of drugs. This report describes a handheld optical fiber probe that contacts the skin, applies pressure to blanch the superficial vascular plexus of the skin, then releases the pressure to allow refill of the plexus. The optical probe uses white light spectroscopy to record the time dynamics of blanching and refilling. The magnitude and dynamics of changes in blood content and hemoglobin oxygen saturation yield an estimate of the oxygen consumption rate (OCR) in units of attomoles per cell per second. The average value of OCR on nine forearm sites on five subjects was 10±5 (amol/cell/s). This low-cost, portable, rapid, noninvasive optical probe can characterize the OCR of a skin site to assess the metabolic activity of the epidermis or a superficial lesion.
Refill non-adherence to repeat prescriptions leads to treatment gaps or to high extra costs.
Krigsman, Kristin; Melander, Arne; Carlsten, Anders; Ekedahl, Anders; Nilsson, J Lars
2007-02-01
To determine the nature and extent of undersupply and the economic consequences of oversupply of medication among non-adherent patients. This study used copies of repeat prescriptions (= multiple dispensations), collected during 1 week in 2002 at 16 Swedish community pharmacies. For patients with a refill adherence below 80%, treatment gaps were defined as the number of days they had no drug available. The cost of drug oversupply (i.e., refill adherence > 120%) was calculated from the prices of the drug packages dispensed. The number of collected repeat prescriptions was 3,636. The median of treatment gaps among patients with a refill adherence below 80% was 53 days per 90-100 days treatment period and the corresponding median for oversupply was 40 days. The cost of oversupply for exempt patients (i.e., patients who have paid 1,800 SEK (Euro 196; US$ 243) per year for medicines) was 32,000 SEK (Euro 3,500; US$ 4,300) higher than for non-exempt patients. An extrapolation to all Sweden indicates that exemption from charges leads to an additional oversupply of about 142 million SEK (Euro 15 million; US$ 19 million) per year above that of non-exempt patients. Both undersupply and oversupply of prescribed medicines are common in Sweden. Patients with a refill adherence below 80% seem to have less than half of the prescribed treatment available. Oversupply or drug stockpiling occurs more frequently among exempt than among non-exempt patients, and this oversupply leads to high unnecessary costs.
Time-resolved observation of thermally activated rupture of a capillary-condensed water nanobridge
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bak, Wan; Sung, Baekman; Kim, Jongwoo
2015-01-05
The capillary-condensed liquid bridge is one of the most ubiquitous forms of liquid in nature and contributes significantly to adhesion and friction of biological molecules as well as microscopic objects. Despite its important role in nanoscience and technology, the rupture process of the bridge is not well understood and needs more experimental works. Here, we report real-time observation of rupture of a capillary-condensed water nanobridge in ambient condition. During slow and stepwise stretch of the nanobridge, we measured the activation time for rupture, or the latency time required for the bridge breakup. By statistical analysis of the time-resolved distribution ofmore » activation time, we show that rupture is a thermally activated stochastic process and follows the Poisson statistics. In particular, from the Arrhenius law that the rupture rate satisfies, we estimate the position-dependent activation energies for the capillary-bridge rupture.« less
Western blotting using capillary electrophoresis.
Anderson, Gwendolyn J; M Cipolla, Cynthia; Kennedy, Robert T
2011-02-15
A microscale Western blotting system based on separating sodium-dodecyl sulfate protein complexes by capillary gel electrophoresis followed by deposition onto a blotting membrane for immunoassay is described. In the system, the separation capillary is grounded through a sheath capillary to a mobile X-Y translation stage which moves a blotting membrane past the capillary outlet for protein deposition. The blotting membrane is moistened with a methanol and buffer mixture to facilitate protein adsorption. Although discrete protein zones could be detected, bands were broadened by ∼1.7-fold by transfer to membrane. A complete Western blot for lysozyme was completed in about one hour with 50 pg mass detection limit from low microgram per milliliter samples. These results demonstrate substantial reduction in time requirements and improvement in mass sensitivity compared to conventional Western blots. Western blotting using capillary electrophoresis shows promise to analyze low volume samples with reduced reagents and time, while retaining the information content of a typical Western blot.
CE-microreactor-CE-MS/MS for protein analysis
Schoenherr, Regine M.; Ye, Mingliang; Vannatta, Michael
2008-01-01
We present a proof-of-principle for a fully automated bottom-up approach to protein characterization. Proteins are first separated by capillary electrophoresis. A pepsin microreactor is incorporated into the distal end of this capillary. Peptides formed in the reactor are transferred to a second capillary, where they are separated by capillary electrophoresis and characterized by mass spectrometry. While peptides generated from one digestion are being separated in the second capillary, the next protein fraction undergoes digestion in the microreactor. The migration time in the first dimension capillary is characteristic of the protein while migration time in the second dimension is characteristic of the peptide. Spot capacity for the two-dimensional separation is 590. A MS/MS analysis of a mixture of cytochrome C and myoglobin generated Mascot MOWSE scores of 107 for cytochrome C and 58 for myoglobin. The sequence coverages were 48% and 22%, respectively. PMID:17295444
33 CFR 150.514 - What are the annual tests and inspections?
Code of Federal Regulations, 2010 CFR
2010-07-01
... boat, and liferaft. At that time, the operator must also empty, clean, and refill each fuel tank with fresh fuel; (b) Thoroughly inspect and, if needed, repair each davit, winch, fall, and other launching... that has passed; (d) Check all lifesaving equipment batteries and replace any battery that is marked...
33 CFR 150.514 - What are the annual tests and inspections?
Code of Federal Regulations, 2012 CFR
2012-07-01
..., the operator must: (a) Strip, clean, thoroughly inspect, and, if needed, repair each lifeboat, rescue boat, and liferaft. At that time, the operator must also empty, clean, and refill each fuel tank with fresh fuel; (b) Thoroughly inspect and, if needed, repair each davit, winch, fall, and other launching...
33 CFR 150.514 - What are the annual tests and inspections?
Code of Federal Regulations, 2013 CFR
2013-07-01
..., the operator must: (a) Strip, clean, thoroughly inspect, and, if needed, repair each lifeboat, rescue boat, and liferaft. At that time, the operator must also empty, clean, and refill each fuel tank with fresh fuel; (b) Thoroughly inspect and, if needed, repair each davit, winch, fall, and other launching...
33 CFR 150.514 - What are the annual tests and inspections?
Code of Federal Regulations, 2011 CFR
2011-07-01
..., the operator must: (a) Strip, clean, thoroughly inspect, and, if needed, repair each lifeboat, rescue boat, and liferaft. At that time, the operator must also empty, clean, and refill each fuel tank with fresh fuel; (b) Thoroughly inspect and, if needed, repair each davit, winch, fall, and other launching...
33 CFR 150.514 - What are the annual tests and inspections?
Code of Federal Regulations, 2014 CFR
2014-07-01
..., the operator must: (a) Strip, clean, thoroughly inspect, and, if needed, repair each lifeboat, rescue boat, and liferaft. At that time, the operator must also empty, clean, and refill each fuel tank with fresh fuel; (b) Thoroughly inspect and, if needed, repair each davit, winch, fall, and other launching...
46 CFR 132.350 - Tests and inspections of fire-extinguishing equipment.
Code of Federal Regulations, 2010 CFR
2010-10-01
... and halon portable fire extinguishers must be refilled when the weight loss of net content exceeds... weight loss exceeds 10% of weight of charge. Test time delays, alarms, and ventilation shutdowns with.... Inspect hoses and nozzles to be sure they are clean. Halon Weigh cylinders. Recharge if weight loss...
46 CFR 132.350 - Tests and inspections of fire-extinguishing equipment.
Code of Federal Regulations, 2011 CFR
2011-10-01
... and halon portable fire extinguishers must be refilled when the weight loss of net content exceeds... weight loss exceeds 10% of weight of charge. Test time delays, alarms, and ventilation shutdowns with.... Inspect hoses and nozzles to be sure they are clean. Halon Weigh cylinders. Recharge if weight loss...
Capillary transit time heterogeneity and flow-metabolism coupling after traumatic brain injury
Østergaard, Leif; Engedal, Thorbjørn S; Aamand, Rasmus; Mikkelsen, Ronni; Iversen, Nina K; Anzabi, Maryam; Næss-Schmidt, Erhard T; Drasbek, Kim R; Bay, Vibeke; Blicher, Jakob U; Tietze, Anna; Mikkelsen, Irene K; Hansen, Brian; Jespersen, Sune N; Juul, Niels; Sørensen, Jens CH; Rasmussen, Mads
2014-01-01
Most patients who die after traumatic brain injury (TBI) show evidence of ischemic brain damage. Nevertheless, it has proven difficult to demonstrate cerebral ischemia in TBI patients. After TBI, both global and localized changes in cerebral blood flow (CBF) are observed, depending on the extent of diffuse brain swelling and the size and location of contusions and hematoma. These changes vary considerably over time, with most TBI patients showing reduced CBF during the first 12 hours after injury, then hyperperfusion, and in some patients vasospasms before CBF eventually normalizes. This apparent neurovascular uncoupling has been ascribed to mitochondrial dysfunction, hindered oxygen diffusion into tissue, or microthrombosis. Capillary compression by astrocytic endfeet swelling is observed in biopsies acquired from TBI patients. In animal models, elevated intracranial pressure compresses capillaries, causing redistribution of capillary flows into patterns argued to cause functional shunting of oxygenated blood through the capillary bed. We used a biophysical model of oxygen transport in tissue to examine how capillary flow disturbances may contribute to the profound changes in CBF after TBI. The analysis suggests that elevated capillary transit time heterogeneity can cause critical reductions in oxygen availability in the absence of ‘classic' ischemia. We discuss diagnostic and therapeutic consequences of these predictions. PMID:25052556
27 CFR 70.149 - Refiling of notice of tax lien.
Code of Federal Regulations, 2010 CFR
2010-04-01
... provided in paragraph (b)(2)(i) of this section, no communication (either written or oral) to the Bureau.... (a) In general—(1) Requirement to refile. In order to continue the effect of a notice of lien, the... are filed with respect to a particular tax assessment, the failure to comply with the provision of...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-23
....5 feet from the normal reservoir elevation of 1177.0 feet on December 17, 2012. The applicant proposes to maintain the elevation within 0.25 feet of 1175.5 feet under normal operations until spillway repairs are completed, and the reservoir is refilled. As currently planned, the reservoir will be refilled...
Method and apparatus for filling thermal insulating systems
Arasteh, D.K.
1992-01-14
A method for filling insulated glazing units is disclosed. The method utilizes a vacuum chamber in which the insulated glazing units are placed. The insulated glazing units and vacuum chamber are evacuated simultaneously. The units are then refilled with a low conductance gas such as Krypton while the chamber is simultaneously refilled with air. 3 figs.
Xu, Yin-Yin; Lv, Wen-Juan; Ren, Cui-Ling; Niu, Xiao-Ying; Chen, Hong-Li; Chen, Xing-Guo
2018-01-12
The popularity of novel nanoparticles coated capillary column has aroused widespread attention of researchers. Metal organic frameworks (MOFs) with special structure and chemical properties have received great interest in separation sciences. This work presents the investigation of HKUST-1 (Hong Kong University of Science and Technology-1, called Cu 3 (BTC) 2 or MOF-199) nanoparticles as a new type of coating material for capillary electrochromatography. For the first time, three layers coating (3-LC), five layers coating (5-LC), ten layers coating (10-LC), fifteen layers coating (15-LC), twenty layers coating(20-LC) and twenty-five layers coating (25-LC) capillary columns coated with HKUST-1 nanoparticles were synthesized by covalent bond with in situ, layer-by-layer self-assembly approach. The results of scanning electron microscopy (SEM), X-ray diffraction (XRD) and plasma atomic emission spectrometry (ICP-AES) indicated that HKUST-1 was successfully grafted on the inner wall of the capillary. The separating performances of 3-LC, 5-LC, 10-LC, 15-LC, 20-LC and 25-LC open tubular (OT) capillary columns were studied with some neutral small organic molecules. The results indicated that the neutral small organic molecules were separated successfully with 10-LC, 15-LC and 20-LC OT capillary columns because of the size selectivity of lattice aperture and hydrophobicity of organic ligands. In addition, 10-LC and 15-LC OT capillary columns showed better performance for the separation of certain phenolic compounds. Furthermore, 10-LC, 15-LC and 20-LC OT capillary columns exhibited good intra-day repeatability with the relative standard deviations (RSDs; %) of migration time and peak areas lying in the range of 0.3-1.2% and 0.5-4.2%, respectively. For inter-day reproducibility, the RSDs of the three OT capillary columns were found to be lying in the range of 0.3-5.5% and 0.3-4.5% for migration time and peak area, respectively. The RSDs of retention times for column-to-column for three batches of 10-LC, 15-LC and 20-LC OT capillary columns were in the range from 2.3% to 7.2%. Moreover, the fabricated 10-LC, 15-LC and 20-LC OT capillary columns exhibited good repeatability and stability for separation, which could be used successively for more than 120 runs with no observable changes on the separation efficiency. Copyright © 2017 Elsevier B.V. All rights reserved.
High-speed video capillaroscopy method for imaging and evaluation of moving red blood cells
NASA Astrophysics Data System (ADS)
Gurov, Igor; Volkov, Mikhail; Margaryants, Nikita; Pimenov, Aleksei; Potemkin, Andrey
2018-05-01
The video capillaroscopy system with high image recording rate to resolve moving red blood cells with velocity up to 5 mm/s into a capillary is considered. Proposed procedures of the recorded video sequence processing allow evaluating spatial capillary area, capillary diameter and central line with high accuracy and reliability independently on properties of individual capillary. Two-dimensional inter frame procedure is applied to find lateral shift of neighbor images in the blood flow area with moving red blood cells and to measure directly the blood flow velocity along a capillary central line. The developed method opens new opportunities for biomedical diagnostics, particularly, due to long-time continuous monitoring of red blood cells velocity into capillary. Spatio-temporal representation of capillary blood flow is considered. Experimental results of direct measurement of blood flow velocity into separate capillary as well as capillary net are presented and discussed.
Belcaro, G; D'Aulerio, A; Rulo, A; Candiani, C
1988-01-01
A new system to study capillary permeability, the VSC (vacuum suction chamber) device has been developed to evaluate the variations of capillary permeability in postphlebitic limbs. The VSC device produces by negative pressure [obtained in a plastic chamber applied to the skin at the perimalleolar region] a wheal which disappears in normals in less than one hour. In twelve patients with moderate [superficial] venous hypertension and in twelve patients with postphlebitic limbs the time of disappearance of the wheals was significantly longer in comparison with ten normal limbs. There was also a significantly increased time of disappearance of the wheals in postphlebitic legs in comparison with those with superficial incompetence. The validation of the VSC technique with venous occlusion plethysmography (VOP) showed that the increase of time of disappearance of the wheals is well correlated with the increase of capillary permeability demonstrated by VOP. After 2 weeks treatment with Venoruton (at the dosage of 1000 mg t.i.d.) the time of disappearance of the wheal was significantly reduced in both groups of patients (while it was unchanged in normals). Laser-Doppler parameters used together with the VSC device to evaluate the microcirculatory changes associated with an altered capillary permeability also showed a significant improvement of the laser-Doppler parameters after treatment. In conclusion there is evidence by the VSC device that capillary permeability [which is abnormally increased] in chronic venous hypertension is improved [decreased] after treatment for two weeks with Venoruton. This study demonstrated also the efficacy of the VSC device to study capillary permeability and the effects of drugs active on capillary permeability.
Ward, David G; Blyde, David; Lemon, John; Johnston, Steve
2006-06-01
Seven captive male African wild dogs (Lycaon pictus) weighing 25-32 kg each, were anesthetized by i.m. injection via hand syringe with a combination of 1.5 mg/kg ketamine, 40 microg/kg medetomidine, and 0.05 mg/kg atropine. Following endotracheal intubation, each animal was connected to a bain closed-circuit system that delivered 1.5% isoflurane and 2 L/min oxygen. Atipamezole (0.1 mg/kg i.v.; 0.1 mg/kg i.m.) was given at the end of each procedure (60 min following injection of medetomidine/ketamine/atropine). Time to sternal recumbency was 5-8 min. Times to standing after atipamezole administration were 8-20 min. This anesthetic regimen was repeated on three separate occasions (September 2000, February 2002, and October 2002) on all males to perform electroejaculation procedures. Each procedure was <80 min from injection to standing. Dogs showed excellent muscle relaxation during the procedures. Arterial blood samples were collected at 10-min intervals for blood gases in one procedure (September 2000). Separate venous samples were taken from each dog during each procedure for hematology and biochemistry. These values were within the normal range for this species. Arterial hemoglobin oxygen saturation (SpO2) and heart rate (HR) were monitored continuously in addition to other anesthesia monitoring procedures (body temperature, respiratory rate [RR], capillary refill time, blink response, pupil position, deep pain perception reflex). All dogs maintained relatively stable SpO2 profiles during monitoring, with a mean (+/-SD) SpO2 of 92% +/-5.4%. All other physiological variables (HR, RR, body temperature, blood pressure) were within normal limits. Following each procedure, normal behavior was noted in all dogs. All the dogs were reunited into the pack at completion of their anesthetic procedures. An injectable medetomidine-ketamine-atropine combination with maintenance by gaseous isoflurane and oxygen provides an inexpensive, reliable anesthetic for captive African wild dogs.
Kim, Chun-Ja; Park, Eunyoung; Schlenk, Elizabeth A; Kim, Moonsun; Kim, Dae Jung
2016-04-01
The purpose of the study was to examine the reliability and validity of the Adherence to Refills and Medications Scale-Korean (ARMS-K) among Korean adults with type 2 diabetes. The Korean translated ARMS-K was back-translated to ensure translation equivalency. A cross-sectional survey was used to evaluate the psychometric properties with exploratory factor analysis for validity and Cronbach's alpha coefficients for reliability. The factor analysis of construct validity identified 3 dimensions of the ARMS-K, explaining 54.7% of the total variance. The internal consistency reliability for the total instrument was acceptable with a Cronbach's alpha of .801. There was good correlation between the ARMS-K and 8-item Morisky Medication Adherence Scale-Korean version (r = -0.698), indicating that these scales measure theoretically related constructs as evidence of convergent validity. As evidence of known groups validity, there was a significant association between the ARMS-K score and glycemic control (P = .048), indicating that the good glycemic controlled group was more likely to have a higher rate of adherence to refills and medications than the poor glycemic controlled group. These results support the cross-cultural applicability of the concepts underlying the ARMS-K. The ARMS-K can be used not only to assess adherence to refills and medications in Koreans with diabetes but also to examine the potential role of adherence to refills and medications in enhanced glycemic control of people with diabetes in a variety of clinical settings. © 2016 The Author(s).
Kim, Sungroul; Goniewicz, Maciej L.; Yu, Sol; Kim, Bokyeong; Gupta, Ribhav
2015-01-01
Background: In South Korea, the consumption of liquid nicotine used in electronic cigarettes has dramatically increased from 4310 L in 2012 to 7220 L in 2013. This study aimed to examine the level of heterogeneity of contents of the labels and discrepancy of the nicotine content between that indicated on the label and the actual values for electronic cigarette liquid refill products in South Korea. Methods: We purchased 32 electronic cigarette liquid refill products (17 Korean domestic, 15 imported ones) and one pure nicotine product at six different electronic cigarette retail stores in Seoul between May and June 2014. The actual nicotine concentrations of each product were measured by a blinded analyst at Roswell Park Cancer Institute, Buffalo, NY, USA. Results: Three out of 15 imported liquid refill products provided manufacturing dates, while expiration dates were available on eight products. The range of nicotine concentration was from “not detected” to 17.5 mg/mL. Labeling discrepancies of the concentrations ranged from −32.2% to 3.3% among electronic cigarette liquid refill products. The highest concentration (150.3 ± 7.9 mg/mL) was found in a sample labeled as “pure nicotine”. Conclusions: There is no standardization of labelling among electronic cigarette liquids sampled from retail stores and the labels did not accurately reflect the content. One product labeled “pure nicotine” raises concerns, since it may be poisonous to consumers, especially to children. This study revealed the urgent need for the development of product regulations in South Korea. PMID:25950652
Guo, Heying; Niu, Xiaoying; Pan, Congjie; Yi, Tao; Chen, Hongli; Chen, Xingguo
2017-06-01
Inspired by the chiral recognition ability of β-cyclodextrin and the natural adhesive properties of polydopamine under alkaline conditions, in this study, a rapid and in situ modification strategy was developed to fabricate β-cyclodextrin/polydopamine composite material coated-capillary columns for open tubular capillary electrochromatography. The results of scanning electron microscopy, FTIR spectroscopy, streaming potential, and electro-osmotic flow studies indicated that β-cyclodextrin/polydopamine was successfully fixed on the inner wall of the capillary column. This coating can be achieved within 1 h affording a greatly reduced capillary preparation time. The performance of the β-cyclodextrin/polydopamine-coated capillary was validated by the analysis of seven pairs of chiral analytes, namely epinephrine, norepinephrine, isoprenaline, terbutaline, verapamil, tryptophane, carvedilol. Good enantioseparation efficiencies were achieved for all. For three consecutive runs, the relative standard deviations for the migration times of the analytes for intraday, interday, and column-to-column repeatability were in the range of 0.41-1.74, 1.03-4.18, and 1.66-8.24%, respectively. Moreover, the separation efficiency of the β-cyclodextrin/polydopamine-coated capillary column did not decrease obviously over 90 runs. The strategy should also be feasible to introduce and immobilize other chiral selectors on the inner walls surface of capillary columns. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Noise suppressing capillary separation system
Yeung, Edward S.; Xue, Yongjun
1996-07-30
A noise-suppressing capillary separation system for detecting the real-time presence or concentration of an analyte in a sample is provided. The system contains a capillary separation means through which the analyte is moved, a coherent light source that generates a beam which is split into a reference beam and a sample beam that irradiate the capillary, and a detector for detecting the reference beam and the sample beam light that transmits through the capillary. The laser beam is of a wavelength effective to be absorbed by a chromophore in the capillary. The system includes a noise suppressing system to improve performance and accuracy without signal averaging or multiple scans.
Noise suppressing capillary separation system
Yeung, E.S.; Xue, Y.
1996-07-30
A noise-suppressing capillary separation system for detecting the real-time presence or concentration of an analyte in a sample is provided. The system contains a capillary separation means through which the analyte is moved, a coherent light source that generates a beam which is split into a reference beam and a sample beam that irradiate the capillary, and a detector for detecting the reference beam and the sample beam light that transmits through the capillary. The laser beam is of a wavelength effective to be absorbed by a chromophore in the capillary. The system includes a noise suppressing system to improve performance and accuracy without signal averaging or multiple scans. 13 figs.
76 FR 16823 - Robert L. Dougherty, M.D.; Denial of Application
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-25
... that's a refill. On the other hand, if the patient calls me back a month later and says I need this... say give Ms. Doe another 30 tablets or whatever. Legally, I think it's a new prescription. Some people...[.] * * * [W]hether I use the word refill or say give the patient another 30 tablets, basically, it means I've...
Drug vaping applied to cannabis: Is “Cannavaping” a therapeutic alternative to marijuana?
Varlet, Vincent; Concha-Lozano, Nicolas; Berthet, Aurélie; Plateel, Grégory; Favrat, Bernard; De Cesare, Mariangela; Lauer, Estelle; Augsburger, Marc; Thomas, Aurélien; Giroud, Christian
2016-01-01
Therapeutic cannabis administration is increasingly used in Western countries due to its positive role in several pathologies. Dronabinol or tetrahydrocannabinol (THC) pills, ethanolic cannabis tinctures, oromucosal sprays or table vaporizing devices are available but other cannabinoids forms can be used. Inspired by the illegal practice of dabbing of butane hashish oil (BHO), cannabinoids from cannabis were extracted with butane gas, and the resulting concentrate (BHO) was atomized with specific vaporizing devices. The efficiency of “cannavaping,” defined as the “vaping” of liquid refills for e-cigarettes enriched with cannabinoids, including BHO, was studied as an alternative route of administration for therapeutic cannabinoids. The results showed that illegal cannavaping would be subjected to marginal development due to the poor solubility of BHO in commercial liquid refills (especially those with high glycerin content). This prevents the manufacture of liquid refills with high BHO concentrations adopted by most recreational users of cannabis to feel the psychoactive effects more rapidly and extensively. Conversely, “therapeutic cannavaping” could be an efficient route for cannabinoids administration because less concentrated cannabinoids-enriched liquid refills are required. However, the electronic device marketed for therapeutic cannavaping should be carefully designed to minimize potential overheating and contaminant generation. PMID:27228348
Tan, Tsung; Watts, Stephanie W.; Davis, Robert Patrick
2011-01-01
Successful drug delivery using implantable pumps may be found in over 12,500 published articles. Their versatility in delivering continuous infusion, intermittent or complex infusion protocols acutely or chronically has made them ubiquitous in drug discovery and basic research. The recent availability of iPRECIO®, a programmable, refillable, and implantable infusion pump has made it possible to carry out quantitative pharmacology (PKPD) in single animals. When combined with specialized catheters, specific administration sites have been selected. When combined with radiotelemetry, the physiologic gold standard, more sensitive and powerful means of detecting drug induced therapeutic, and/or adverse effects has been possible. Numerous application examples are cited from iPRECIO® use in Japan, United States, and Europe with iPRECIO® as an enabling drug delivery device where the refillable and programmability functionality were key benefits. The ability to start/stop drug delivery and to have control periods prior dosing made it possible to have equivalent effects at a much lower dose than previously studied. Five different iPRECIO® applications are described in detail with references to the original work where the implantable, refillable, and programmable benefits are demonstrated with their different end-points. PMID:21863140
Analysis of the Functionality of Refillable Propellant Management Devices (PMD)
NASA Astrophysics Data System (ADS)
Winkelmann, Yvonne; Gaulke, Diana; Dreyer, Michael E.
In order to restart a stage of a spacecraft it is necessary to position the liquid stable over the tank outlet. The gas-or vapor-free provision of the thrusters for the main engine start-up can be accomplished by the use of propellant management devices (PMDs). A propellant refillable reservoir (PRR) will supply the engine with the required amount of liquid propellant until the liquid outside the PRR has settled at the bottom of the tank. Hence, the reservoir will be refilled and the main engine can be restarted. This technique has been applied in case of storable propellants yet, e.g. in satellites or ATVs. For the application in a cryogenic upper stage demonstration and validation tests are still necessary. Ground experiments to simulate propulsed phases are evaluated. To demonstrate the functionality under propulsed conditions first filling, draining and draining with a constant fill level of the tank (refilling) are analyzed. Different inflows with respect to filling and varied outflow rates for the draining tests are investigated. Pressure losses in the LOX-PMD are measured during draining and compared to a previously accomplished estimation with an one-dimensional streamtube theory.
Drug vaping applied to cannabis: Is "Cannavaping" a therapeutic alternative to marijuana?
Varlet, Vincent; Concha-Lozano, Nicolas; Berthet, Aurélie; Plateel, Grégory; Favrat, Bernard; De Cesare, Mariangela; Lauer, Estelle; Augsburger, Marc; Thomas, Aurélien; Giroud, Christian
2016-05-26
Therapeutic cannabis administration is increasingly used in Western countries due to its positive role in several pathologies. Dronabinol or tetrahydrocannabinol (THC) pills, ethanolic cannabis tinctures, oromucosal sprays or table vaporizing devices are available but other cannabinoids forms can be used. Inspired by the illegal practice of dabbing of butane hashish oil (BHO), cannabinoids from cannabis were extracted with butane gas, and the resulting concentrate (BHO) was atomized with specific vaporizing devices. The efficiency of "cannavaping," defined as the "vaping" of liquid refills for e-cigarettes enriched with cannabinoids, including BHO, was studied as an alternative route of administration for therapeutic cannabinoids. The results showed that illegal cannavaping would be subjected to marginal development due to the poor solubility of BHO in commercial liquid refills (especially those with high glycerin content). This prevents the manufacture of liquid refills with high BHO concentrations adopted by most recreational users of cannabis to feel the psychoactive effects more rapidly and extensively. Conversely, "therapeutic cannavaping" could be an efficient route for cannabinoids administration because less concentrated cannabinoids-enriched liquid refills are required. However, the electronic device marketed for therapeutic cannavaping should be carefully designed to minimize potential overheating and contaminant generation.
Ruan, Xiulu; Couch, J Patrick; Liu, HaiNan; Shah, Rinoo V; Wang, Frank; Chiravuri, Srinivas
2010-01-01
Spinal analgesia, mediated by opioid receptors, requires only a fraction of the opioid dose that is needed systemically. By infusing a small amount of opioid into the cerebrospinal fluid in close proximity to the receptor sites in the spinal cord, profound analgesia may be achieved while sparing some of the side effects due to systemic opioids. Intraspinal drug delivery (IDD) has been increasingly used in patients with intractable chronic pain, when these patients have developed untoward side effects with systemic opioid usage. The introduction of intrathecal opioids has been considered one of the most important breakthroughs in pain management in the past three decades. A variety of side effects associated with the long-term usage of IDD have been recognized. Among them, respiratory depression is the most feared. To describe a severe adverse event, i.e., respiratory failure, following delayed intrathecal morphine pump refill. A 65-year-old woman with intractable chronic low back pain, due to degenerative disc disease, and was referred to our clinic for an intraspinal drug delivery evaluation, after failing to respond to multidisciplinary pain treatment. Following a psychological evaluation confirming her candidacy, she underwent an outpatient patient-controlled continuous epidural morphine infusion trial. The infusion trial lasted 12 days and was beneficial in controlling her pain. The patient reported more than 90% pain reduction with improved distance for ambulation. She subsequently consented and was scheduled for permanent intrathecal morphine pump implantation. The intrathecal catheter was inserted at right paramedian L3-L4, with catheter tip advanced to L1, confirmed under fluoroscopy. Intrathecal catheter placement was confirmed by positive CSF flow and by myelogram. A non-programmable Codman 3000 constant-flow rate infusion pump was placed in the right mid quandrant between right rib cage and right iliac crest. The intrathecal infusion consisted of preservative free morphine, delivering 1.0 mg /day. Over the following 6 months, the dosage was gradually titrated up to 4 mg/day with satisfactory pain control without significant side effects. However, the patient was not able to return to the clinic for pump refill until 12 days later than the previously scheduled pump-refill date. Her pump was accessed and was noted to be empty. Her intrathecal pump was refilled with preservative free morphine, delivering 4 mg/day (the same daily dose as her previous refill). However, on the night of pump refill, 10 hours after the pump refill, the patient was found to be unresponsive by her family members. 911 was called. Upon arriving, paramedics found her in respiratory failure, with shallow breathing at a rate of 5/min, pulse oxymetry showing oxygen saturation about 55-58%. She was emergently intubated on site and rushed to local hospital ER. The on call physician for our clinic was immediately contacted, and advised the administration of intravenous Naloxone. Her respiratory effort improved dramatically after receiving a total of 0.6 mg IV Naloxone IV over 25 minutes. Her intrathecal pump was immediately accessed by clinic on call physician and the remainder of the medication in the catheter space was aspirated. The pump infusate was immediately diluted with preservative free normal saline, to deliver preservative free morphine at 1mg/day. She was transferred to the intensive care unit and extubated the next morning. She recovered fully without any sequelae. Loss of opioid tolerance due to delayed pump refill may subject patients to the development of severe respiratory depression. Meticulous approach should be employed when refilling pumps in these patients when their pumps are completely empty. To our knowledge, this is the first reported case of this type.
Skin contamination as pathway for nicotine intoxication in vapers.
Maina, Giovanni; Castagnoli, Carlotta; Ghione, Giordana; Passini, Valter; Adami, Gianpiero; Larese Filon, Francesca; Crosera, Matteo
2017-06-01
Growing warnings on health effects related to electronic cigarettes have met inconclusive findings at present. This study analyzed the in vitro percutaneous absorption of nicotine resulting by skin contamination with two e-liquids (refill 1 and 2) containing nicotine at 1.8%. Donor chambers of 6 Franz cells for each refill liquid were filled with 1mL of nicotine e-liquid for 24h; at selected intervals, 1.5mL of the receptor solutions were collected for nicotine concentration analysis by mean gas chromatography-mass spectrometry (LOD: 0.01μg/mL). The experiment was repeated removing the nicotine donor solution after 10min from the application and rinsing the skin surface three times with 3.0mL of milliQ water. A total of 12 cells with 24h exposure and 12 cells washed were studied. The mean concentration of nicotine in the receiving phase at the end of the experiment was 54.9±29.5 and 30.2±18.4μg/cm 2 for refill 1 and 2 respectively and significantly lower in washed cells (4.7±2.4 and 3.5±1.3μg/cm 2 ). The skin absorption of nicotine can lead to minor health illness in vapers, while caution must be paid to dermal contamination by e liquids in children. The skin cleaning significantly reduced the transdermal absorption kinetic and intradermal deposition of nicotine. Copyright © 2017 Elsevier B.V. All rights reserved.
Ashraf, Sania; Nizame, Fosiul A; Islam, Mahfuza; Dutta, Notan C; Yeasmin, Dalia; Akhter, Sadika; Abedin, Jaynal; Winch, Peter J; Ram, Pavani K; Unicomb, Leanne; Leontsini, Elli; Luby, Stephen P
2017-02-08
We conducted a nonrandomized trial of strategies to promote soapy water for handwashing in rural Bangladesh and measured uptake. We enrolled households with children < 3 years for three progressively intensive study arms: promotion of soapy water ( N = 120), soapy water promotion plus handwashing stations ( N = 103), and soapy water promotion, stations plus detergent refills ( N = 90); we also enrolled control households ( N = 72). Our handwashing stations included tap-fitted buckets and soapy water bottles. Community promoters visited households and held community meetings to demonstrate soapy water preparation and promote handwashing at key times. Field workers measured uptake 4 months later. In-depth interviews and focus group discussions assessed factors associated with uptake. More households had soapy water at the handwashing place in progressively intensive arms: 18% (promotion), 60% (promotion plus station), and 71% (promotion, station with refills). Compared with the promotion-only arm, more households that received stations had soapy water at the primary handwashing station (44%, P ≤ 0.001; 71%, P < 0.001 with station plus detergent refill). Qualitative findings highlighted several dimensions that affected use: contextual (shared courtyard), psychosocial (perceived value), and technology dimensions (ease of use, convenience). Soapy water may increase habitual handwashing by addressing barriers of cost and availability of handwashing agents near water sources. Further research should inform optimal strategies to scale-up soapy water as a handwashing agent to study health impact. © The American Society of Tropical Medicine and Hygiene.
Ashraf, Sania; Nizame, Fosiul A.; Islam, Mahfuza; Dutta, Notan C.; Yeasmin, Dalia; Akhter, Sadika; Abedin, Jaynal; Winch, Peter J.; Ram, Pavani K.; Unicomb, Leanne; Leontsini, Elli; Luby, Stephen P.
2017-01-01
We conducted a nonrandomized trial of strategies to promote soapy water for handwashing in rural Bangladesh and measured uptake. We enrolled households with children < 3 years for three progressively intensive study arms: promotion of soapy water (N = 120), soapy water promotion plus handwashing stations (N = 103), and soapy water promotion, stations plus detergent refills (N = 90); we also enrolled control households (N = 72). Our handwashing stations included tap-fitted buckets and soapy water bottles. Community promoters visited households and held community meetings to demonstrate soapy water preparation and promote handwashing at key times. Field workers measured uptake 4 months later. In-depth interviews and focus group discussions assessed factors associated with uptake. More households had soapy water at the handwashing place in progressively intensive arms: 18% (promotion), 60% (promotion plus station), and 71% (promotion, station with refills). Compared with the promotion-only arm, more households that received stations had soapy water at the primary handwashing station (44%, P ≤ 0.001; 71%, P < 0.001 with station plus detergent refill). Qualitative findings highlighted several dimensions that affected use: contextual (shared courtyard), psychosocial (perceived value), and technology dimensions (ease of use, convenience). Soapy water may increase habitual handwashing by addressing barriers of cost and availability of handwashing agents near water sources. Further research should inform optimal strategies to scale-up soapy water as a handwashing agent to study health impact. PMID:28025233
Posttest analysis of international standard problem 10 using RELAP4/MOD7. [PWR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hsu, M.; Davis, C.B.; Peterson, A.C. Jr.
RELAP4/MOD7, a best estimate computer code for the calculation of thermal and hydraulic phenomena in a nuclear reactor or related system, is the latest version in the RELAP4 code development series. This paper evaluates the capability of RELAP4/MOD7 to calculate refill/reflood phenomena. This evaluation uses the data of International Standard Problem 10, which is based on West Germany's KWU PKL refill/reflood experiment K9A. The PKL test facility represents a typical West German four-loop, 1300 MW pressurized water reactor (PWR) in reduced scale while maintaining prototypical volume-to-power ratio. The PKL facility was designed to specifically simulate the refill/reflood phase of amore » hypothetical loss-of-coolant accident (LOCA).« less
Capillary red blood cell velocimetry by phase-resolved optical coherence tomography
NASA Astrophysics Data System (ADS)
Tang, Jianbo; Erdener, Sefik Evren; Fu, Buyin; Boas, David A.
2018-02-01
Quantitative measurement of blood flow velocity in capillaries is challenging due to their small size (around 5-10 μm), and the discontinuity and single-file feature of RBCs flowing in a capillary. In this work, we present a phase-resolved Optical Coherence Tomography (OCT) method for accurate measurement of the red blood cell (RBC) speed in cerebral capillaries. To account for the discontinuity of RBCs flowing in capillaries, we applied an M-mode scanning strategy that repeated A-scans at each scanning position for an extended time. As the capillary size is comparable to the OCT resolution size (3.5×3.5×3.5μm), we applied a high pass filter to remove the stationary signal component so that the phase information of the dynamic component (i.e. from the moving RBC) could be enhanced to provide an accurate estimate of the RBC axial speed. The phase-resolved OCT method accurately quantifies the axial velocity of RBC's from the phase shift of the dynamic component of the signal. We validated our measurements by RBC passage velocimetry using the signal magnitude of the same OCT time series data. These proposed method of capillary velocimetry proved to be a robust method of mapping capillary RBC speeds across the micro-vascular network.
Visualization and quantification of two-phase flow in transparent miniature packed beds
NASA Astrophysics Data System (ADS)
Zhu, Peixi; Papadopoulos, Kyriakos D.
2012-10-01
Optical microscopy was used to visualize the flow of two phases [British Petroleum (BP) oil and an aqueous surfactant phase] in confined space, three-dimensional, transparent, natural porous media. The porous media consisted of water-wet cryolite grains packed inside cylindrical, glass microchannels, thus producing microscopic packed beds. Primary drainage of BP oil displacing an aqueous surfactant phase was studied at capillary numbers that varied between 10-6 and 10-2. The confinement space had a significant effect on the flow behavior. Phenomena of burst motion and capillary fingering were observed for low capillary numbers due to the domination of capillary forces. It was discovered that breakthrough time and capillary number bear a log-log scale linear relationship, based on which a generalized correlation between oil travel distance x and time t was found empirically.
Visualization and quantification of two-phase flow in transparent miniature packed beds.
Zhu, Peixi; Papadopoulos, Kyriakos D
2012-10-01
Optical microscopy was used to visualize the flow of two phases [British Petroleum (BP) oil and an aqueous surfactant phase] in confined space, three-dimensional, transparent, natural porous media. The porous media consisted of water-wet cryolite grains packed inside cylindrical, glass microchannels, thus producing microscopic packed beds. Primary drainage of BP oil displacing an aqueous surfactant phase was studied at capillary numbers that varied between 10(-6) and 10(-2). The confinement space had a significant effect on the flow behavior. Phenomena of burst motion and capillary fingering were observed for low capillary numbers due to the domination of capillary forces. It was discovered that breakthrough time and capillary number bear a log-log scale linear relationship, based on which a generalized correlation between oil travel distance x and time t was found empirically.
Hanson, Josh; Lam, Sophia W K; Alam, Shamsul; Pattnaik, Rajyabardhan; Mahanta, Kishore C; Uddin Hasan, Mahatab; Mohanty, Sanjib; Mishra, Saroj; Cohen, Sophie; Day, Nicholas; White, Nicholas; Dondorp, Arjen
2013-10-01
Adults with severe malaria frequently require intravenous fluid therapy to restore their circulating volume. However, fluid must be delivered judiciously as both under- and over-hydration increase the risk of complications and, potentially, death. As most patients will be cared for in a resource-poor setting, management guidelines necessarily recommend that physical examination should guide fluid resuscitation. However, the reliability of this strategy is uncertain. To determine the ability of physical examination to identify hypovolaemia, volume responsiveness, and pulmonary oedema, clinical signs and invasive measures of volume status were collected independently during an observational study of 28 adults with severe malaria. The physical examination defined volume status poorly. Jugular venous pressure (JVP) did not correlate with intravascular volume as determined by global end diastolic volume index (GEDVI; r(s) = 0.07, p = 0.19), neither did dry mucous membranes (p = 0.85), or dry axillae (p = 0.09). GEDVI was actually higher in patients with decreased tissue turgor (p < 0.001). Poor capillary return correlated with GEDVI, but was present infrequently (7% of observations) and, therefore, insensitive. Mean arterial pressure (MAP) correlated with GEDVI (rs = 0.16, p = 0.002), but even before resuscitation patients with a low GEDVI had a preserved MAP. Anuria on admission was unrelated to GEDVI and although liberal fluid resuscitation led to a median hourly urine output of 100 ml in 19 patients who were not anuric on admission, four (21%) developed clinical pulmonary oedema subsequently. MAP was unrelated to volume responsiveness (p = 0.71), while a low JVP, dry mucous membranes, dry axillae, increased tissue turgor, prolonged capillary refill, and tachycardia all had a positive predictive value for volume responsiveness of ≤50%. Extravascular lung water ≥11 ml/kg indicating pulmonary oedema was present on 99 of the 353 times that it was assessed during the study, but was identified on less than half these occasions by tachypnoea, chest auscultation, or an elevated JVP. A clear chest on auscultation and a respiratory rate <30 breaths/minute could exclude pulmonary oedema on 82% and 72% of occasions respectively. Findings on physical examination correlate poorly with true volume status in adults with severe malaria and must be used with caution to guide fluid therapy. Clinicaltrials.gov identifier: NCT00692627.
NASA Astrophysics Data System (ADS)
Schlicker, Lukas; Doran, Andrew; Schneppmüller, Peter; Gili, Albert; Czasny, Mathias; Penner, Simon; Gurlo, Aleksander
2018-03-01
This work describes a device for time-resolved synchrotron-based in situ and operando X-ray powder diffraction measurements at elevated temperatures under controllable gaseous environments. The respective gaseous sample environment is realized via a gas-tight capillary-in-capillary design, where the gas flow is achieved through an open-end 0.5 mm capillary located inside a 0.7 mm capillary filled with a sample powder. Thermal mass flow controllers provide appropriate gas flows and computer-controlled on-the-fly gas mixing capabilities. The capillary system is centered inside an infrared heated, proportional integral differential-controlled capillary furnace allowing access to temperatures up to 1000 °C.
Migration And Entrapment Of Mercury In The Subsurface
NASA Astrophysics Data System (ADS)
M, D.; Nambi, I. M.
2009-12-01
Elemental mercury is an immiscible liquid with high density and high surface tension. The movement of mercury in the saturated subsurface region is therefore considered a case of two phase flow involving mercury and water and is expected to be governed by gravity, viscous and capillary forces. Fundamental investigation into the migration and capillary entrapment of mercury in the subsurface was done by controlled laboratory capillary pressure saturation experiments using mercury and water as non wetting and wetting fluid respectively. Residual mercury saturation and van Genuchten’s capillary entrapment parameters were determined independently for different sizes of porous media. Based on the experimental data, theoretical investigations were done on the role of the three predominant forces and their influence on mercury migration and entrapment. The effects of fluid density and interfacial tension and the influence of Capillary and Bond number on mercury entrapment were analyzed with the help of similar capillary pressure - saturation experiments using Tetrachloroethylene (PCE)-water fluid pair. Mercury-water systems exhibited a low residual saturation of 0.02 and 0.07 as compared to 0.16 and 0.27 for PCE-water systems. Less residual mercury saturation, lack of apparent hysteresis in capillary pressure saturation curves and large variation in van Genuchten’s parameters 'α'(inverse of displacement pressure) and ‘n’ (pore size distribution index) for mercury-water systems compared to PCE-water systems were observed. These anomalies between the two systems elucidate that the capillary trapping is equally dependent on the fluid characteristics especially for high density immiscible fluids. Gravity force nevertheless a predominant controlling factor in the migration of highly dense mercury, is counteracted by not less trivial capillary force which was 1.22x104 times higher than gravity force. The capillary forces thus surmount the gravity forces and cause entrapment of mercury in the soil pores even in homogeneous porous medium system. Bond number (Bond number relates gravity and capillary forces) for mercury-water system was found to 2.5 times higher than PCE-water systems. Large density differences between mercury and water lead to high Bond number and thus less residual saturation. Capillary number (Capillary number relates viscous and capillary forces) was found to be less for mercury-water systems. Literature review unveils that low Capillary number does not influence non wetting residual saturation. But for high density mercury with natural infiltration, even low Capillary number influences residual saturation. With the alarming increase in number of mercury spill sites, results of this study showed a better understanding of the capillary entrapment phenomena and the extent of influence of each predominant force during displacement of highly dense mercury. The fundamental inputs to NAPL entrapment models were generated in this study for mercury for the first time. This data will be used to assess the distribution of mercury in contaminated sites and design suitable remedial alternatives.
Dickerson, Jane A.; Ramsay, Lauren M.; Dada, Oluwatosin O.; Cermak, Nathan
2011-01-01
Capillary isoelectric focusing and capillary zone electrophoresis are coupled with laser-induced fluorescence detection to create an ultrasensitive two-dimensional separation method for proteins. In this method, two capillaries are joined through a buffer filled interface. Separate power supplies control the potential at the injection end of the first capillary and at the interface; the detector is held at ground potential. Proteins are labeled with the fluorogenic reagent Chromeo P503, which preserves the isoelectric point of the labeled protein. The labeled proteins were mixed with ampholytes and injected into the first dimension capillary. A focusing step was performed with the injection end of the capillary at high pH and the interface at low pH. To mobilize components, the interface was filled with a high pH buffer, which was compatible with the second dimension separation. A fraction was transferred to the second dimension capillary for separation. The process of fraction transfer and second dimension separation was repeated two dozen times. The separation produced a spot capacity of 125. PMID:20603830
Capillarics: pre-programmed, self-powered microfluidic circuits built from capillary elements.
Safavieh, Roozbeh; Juncker, David
2013-11-07
Microfluidic capillary systems employ surface tension effects to manipulate liquids, and are thus self-powered and self-regulated as liquid handling is structurally and chemically encoded in microscale conduits. However, capillary systems have been limited to perform simple fluidic operations. Here, we introduce complex capillary flow circuits that encode sequential flow of multiple liquids with distinct flow rates and flow reversal. We first introduce two novel microfluidic capillary elements including (i) retention burst valves and (ii) robust low aspect ratio trigger valves. These elements are combined with flow resistors, capillary retention valves, capillary pumps, and open and closed reservoirs to build a capillary circuit that, following sample addition, autonomously delivers a defined sequence of multiple chemicals according to a preprogrammed and predetermined flow rate and time. Such a circuit was used to measure the concentration of C-reactive protein. This work illustrates that as in electronics, complex capillary circuits may be built by combining simple capillary elements. We define such circuits as "capillarics", and introduce symbolic representations. We believe that more complex circuits will become possible by expanding the library of building elements and formulating abstract design rules.
NASA Astrophysics Data System (ADS)
Kuroda, S.; Ishii, N.; Morii, T.
2017-12-01
Capillary barriers have been known as the method to protect subsurface regions against infiltration from soil surface. It is caused by essentially heterogeneous structure in permeability or soil physical property and produce non-uniform infiltration process then, in order to estimate the actual situation of the capillary barrier effect, the site-characterization with imaging technique like geophysical prospecting is effective. In this study, we examine the applicability of GPR to characterization for capillary barriers. We built a sand box with 90x340x90cm in which a thin high-permeable gravel layer was embedded as a capillary barrier. We conducted an infiltration test in the sand box using porous tube array for irrigation. It is expected to lead to non-uniform flow of soil water induced by capillary barrier effects. We monitored this process by various types of GPR measurements, including time-lapsed common offset profiling (COP) with multi- frequency antenna and transmission measurements like cross-borehole radar. At first, we conducted GPR common-offset survey. It could show the depth of capillary barrier in sand box. After that we conducted the infiltration test and GPR monitoring for infiltration process. GPR profiles can detect the wetting front and estimate water content change in the soil layer above the capillary barrier. From spatial change in these results we can estimate the effect of capillary barrier and the zone where the break through occur or not. Based on these results, we will discuss the applicability of GPR for monitoring the phenomena around the capillary barrier of soil. At first, we conducted GPR common-offset survey. It could show the depth of capillary barrier in sand box. After that we conducted the infiltration test and GPR monitoring for infiltration process. GPR profiles can detect the wetting front and estimate water content change in the soil layer above the capillary barrier. From spatial change in these results we can estimate the effect of capillary barrier and the zone where the break through occur. Based on these results, we will discuss the applicability of GPR for monitoring the phenomena around the capillary barrier of soil.
Hirsch, Jan D; Oen, Austin; Robertson, Suzie; Nguyen, Nancy; Daniels, Charles
2009-01-01
To assess the rate of patient-requested pharmacist counseling for refill prescriptions and satisfaction with pick-up process for patients using an automated prescription delivery system (APDS) versus those using a regular pick-up counter and to explore patient willingness to use an APDS as a tool for pharmacist monitoring of medication therapy outcomes. In this uncontrolled, cross-sectional, survey study, we assessed use of APDS or the regular counter by 116 patients picking up refill prescriptions at two community pharmacies. The main outcome measures were number of patients requesting pharmacist counseling for refill prescriptions, patient satisfaction with pick-up process, and patient willingness to use an APDS to report medication therapy outcomes. None of the regular counter users and only two APDS users (3.7%) requested counseling for their refill prescription (P = 0.126). Almost all patients agreed that they were able to talk to a pharmacist about their prescription if they wanted to do so (95.1% regular counter and 92.3% APDS; P = 0.268). The majority (75%) of patients using APDS indicated that they would be willing to use the system to answer questions or perform simple tests to provide information that the pharmacist could use to improve medication effectiveness or reduce adverse effects. Very few patients (ADPS or regular counter) asked to speak to a pharmacist about their refill medications, although it appeared that no perceived barriers to pharmacist access existed. Most APDS patients were willing to use this new technology to provide information about therapy outcomes to the pharmacist. Further exploration and testing of the APDS as a data collection tool to enhance pharmacist access to therapy outcomes is warranted.
Delannoy, Joachim; de Maleprade, Hélène; Clanet, Christophe; Quéré, David
2018-05-31
A superhydrophobic capillary tube immersed in water and brought in contact with the bath surface will be invaded by air, owing to its aerophilicity. We discuss this phenomenon where the ingredients of classical capillary rise are inverted, which leads to noticeable dynamical features. (1) The main regime of air invasion is linear in time, due to the viscous resistance of water. (2) Menisci in tubes with millimetre-size radii strongly oscillate before reaching their equilibrium depth, a consequence of inertia. On the whole, capillary descent provides a broad variety of dynamics where capillary effects, viscous friction and liquid inertia all play a role.
Computer capillaroscopy as a new cardiological diagnostics method
NASA Astrophysics Data System (ADS)
Gurfinkel, Youri I.; Korol, Oleg A.; Kufal, George E.
1998-04-01
The blood flow in capillary vessels plays an important role in sustaining the vital activity of the human organism. The computerized capillaroscope is used for the investigations of nailfold (eponychium) capillary blood flow. An important advantage of the instrument is the possibility of performing non-invasive investigations, i.e., without damage to skin or vessels and causing no pain or unpleasant sensations. The high-class equipment and software allow direct observation of capillary blood flow dynamics on a computer screen at a 700 - 1300 times magnification. For the first time in the clinical practice, it has become possible to precisely measure the speed of capillary blood flow, as well as the frequency of aggregate formation (glued together in clots of blood particles). In addition, provision is made for automatic measurement of capillary size and wall thickness and automatic recording of blood aggregate images for further visual study, documentation, and electronic database management.
PHYSIOLOGICAL DYNAMICS OF SIPHONOPHORES FROM DEEP SCATTERING LAYERS.
Effects of siphonophores on sound propagation in the sea were studied by determining the size of gas bubbles they contain and produce, and the times...volumes, and rates involved in these processes. Major findings were: (1) gases contained in fresh siphonophore floats are generally close to...constants for siphonophore floats are close to those for chitin; (4) calculated energy requirements for countering hydrostatic pressures indicate that float refilling times are probably no more than a few hours. (Author)
Make Time to Recharge: Growth and Renewal Play Key Roles in Sustaining School Leaders
ERIC Educational Resources Information Center
Drago-Severson, Ellie; Blum-DeStefano, Jessica
2015-01-01
Being a school leader in any role is hard, gratifying, and a gift of love. While it can be enormously satisfying to serve students, teachers, families, and school communities, leaders need to refill themselves in order to continue giving to others. This article highlights a learning-oriented model of leadership development and capacity building…
Egu, K; Kinata-Bambino, S; Mounadi, M; Rachid El Maaqili, M; El Abbadi, N
2016-04-01
Capillary hemangiomas are benign endothelial cell neoplasms that are believed to be hamartomatous proliferations of vascular endothelial cells. The occurrence of spinal epidural capillary hemangiomas is exceedingly rare. Only 8 epidurally located cases of capillary hemangiomas in the spinal canal have been reported in the literature. We report for the first time, to our knowledge, a case of lumbosacral epidural capillary hemangioma revealed by S1 back pain and radicular pain in a 60-year-old patient, caused by an L5-S1 epidural capillary hemangioma. The neurological symptoms of the patient improved after surgery. Spinal epidural capillary hemangioma is exceedingly rare. These lesions are benign and can mimic dumbbell-shaped neurinoma. Total removal by surgery is curative. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Stewart, Derek; Smith, Susan M.; Gallagher, Paul; Cousins, Gráinne
2017-01-01
Antihypertensive medication nonadherence is highly prevalent, leading to uncontrolled blood pressure. Methods that facilitate the targeting and tailoring of adherence interventions in clinical settings are required. Group‐Based Trajectory Modeling (GBTM) is a newer method to evaluate adherence using pharmacy dispensing (refill) data that has advantages over traditional refill adherence metrics (e.g. Proportion of Days Covered) by identifying groups of patients who may benefit from adherence interventions, and identifying patterns of adherence behavior over time that may facilitate tailoring of an adherence intervention. We evaluated adherence to antihypertensive medication in 905 patients over a 12‐month period in a community pharmacy setting using GBTM, identifying three subgroups of adherence patterns: 52.8%, 40.7%, and 6.5% had very high, high, and low adherence, respectively. However, GBTM failed to demonstrate predictive validity with blood pressure at 12 months. Further research on the validity of adherence measures that facilitate interventions in clinical settings is required. PMID:28875569
Clathrin coat controls synaptic vesicle acidification by blocking vacuolar ATPase activity
Farsi, Zohreh; Rammner, Burkhard; Woehler, Andrew; Lafer, Eileen M; Mim, Carsten; Jahn, Reinhard
2018-01-01
Newly-formed synaptic vesicles (SVs) are rapidly acidified by vacuolar adenosine triphosphatases (vATPases), generating a proton electrochemical gradient that drives neurotransmitter loading. Clathrin-mediated endocytosis is needed for the formation of new SVs, yet it is unclear when endocytosed vesicles acidify and refill at the synapse. Here, we isolated clathrin-coated vesicles (CCVs) from mouse brain to measure their acidification directly at the single vesicle level. We observed that the ATP-induced acidification of CCVs was strikingly reduced in comparison to SVs. Remarkably, when the coat was removed from CCVs, uncoated vesicles regained ATP-dependent acidification, demonstrating that CCVs contain the functional vATPase, yet its function is inhibited by the clathrin coat. Considering the known structures of the vATPase and clathrin coat, we propose a model in which the formation of the coat surrounds the vATPase and blocks its activity. Such inhibition is likely fundamental for the proper timing of SV refilling. PMID:29652249
Beikircher, Barbara; Mayr, Stefan
2016-01-01
A prerequisite for reliable hydraulic measurements is an accurate collection of the plant material. Thereby, the native hydraulic state of the sample has to be preserved during harvesting (i.e., cutting the plant or plant parts) and preparation (i.e., excising the target section). This is particularly difficult when harvesting has to be done under transpiring conditions. In this article, we present a harvesting and sampling protocol designed for hydraulic measurements on Malus domestica Borkh. and checked for possible sampling artefacts. To test for artefacts, we analysed the percentage loss of hydraulic conductivity, maximum specific conductivity and water contents of bark and wood of branches, taking into account conduit length, time of day of harvesting, different shoot ages and seasonal effects. Our results prove that use of appropriate protocols can avoid artefactual embolization or refilling even when the xylem is under tension at harvest. The presented protocol was developed for Malus but may also be applied for other angiosperms with similar anatomy and refilling characteristics. PMID:26705311
NASA Technical Reports Server (NTRS)
Poberezhskiy, Ilya Y.; Meras, Patrick; Chang, Daniel H.; Spiers, Gary D.
2007-01-01
This slide presentation reviews a method for refilling and connectorization of hollow core photonic crystal fiber gas reference cells. Thees hollow-core photonic crystal fiber allow optical propagation in air or vacuum and are for use as gas reference cell is proposed and demonstrated. It relies on torch-sealing a quartz filling tube connected to a mechanical splice between regular and hollow-core fibers.
Koster, Ellen S; van Meeteren, Marijke M; van Dijk, Marloes; van de Bemt, Bart J F; Ensing, Hendrikus T; Bouvy, Marcel L; Blom, Lyda; van Dijk, Liset
2015-07-01
To describe communication between pharmacy staff and patients at the counter in outpatient pharmacies. Both content and communication style were investigated. Pharmaceutical encounters in three outpatient pharmacies in the Netherlands were video-recorded. Videos were analyzed based on an observation protocol for the following information: content of encounter, initiator of a theme and pharmacy staff's communication style. In total, 119 encounters were recorded which concerned 42 first prescriptions, 16 first refill prescriptions and 61 follow-up refill prescriptions. During all encounters, discussion was mostly initiated by pharmacy staff (85%). In first prescription encounters topics most frequently discussed included instructions for use (83%) and dosage instructions (95%). In first refill encounters, patient experiences such as adverse effects (44%) and beneficial effects (38%) were regularly discussed in contrast to follow-up refills (7% and 5%). Patients' opinion on medication was hardly discussed. Pharmacy staff in outpatient pharmacies generally provide practical information, less frequently they discuss patients' experiences and seldom discuss patients' perceptions and preferences about prescribed medication. This study shows there is room for improvement, as communication is still not according to professional guidelines. To implement professional guidelines successfully, it is necessary to identify underlying reasons for not following the guidelines. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
The inclusion of capillary distribution in the adiabatic tissue homogeneity model of blood flow
NASA Astrophysics Data System (ADS)
Koh, T. S.; Zeman, V.; Darko, J.; Lee, T.-Y.; Milosevic, M. F.; Haider, M.; Warde, P.; Yeung, I. W. T.
2001-05-01
We have developed a non-invasive imaging tracer kinetic model for blood flow which takes into account the distribution of capillaries in tissue. Each individual capillary is assumed to follow the adiabatic tissue homogeneity model. The main strength of our new model is in its ability to quantify the functional distribution of capillaries by the standard deviation in the time taken by blood to pass through the tissue. We have applied our model to the human prostate and have tested two different types of distribution functions. Both distribution functions yielded very similar predictions for the various model parameters, and in particular for the standard deviation in transit time. Our motivation for developing this model is the fact that the capillary distribution in cancerous tissue is drastically different from in normal tissue. We believe that there is great potential for our model to be used as a prognostic tool in cancer treatment. For example, an accurate knowledge of the distribution in transit times might result in an accurate estimate of the degree of tumour hypoxia, which is crucial to the success of radiation therapy.
Properties of large scale plasma flow during the early stage of the plasmaspheric refilling
NASA Technical Reports Server (NTRS)
Singh, Nagendra; Craven, P.; Torr, D. G.; Richards, P. G.
1990-01-01
The objective is to better characterize the macroscopic properties of the interhemisphere plasma flow by solving a more complete set of hydrodynamic equations than that solved previously. Specifically, the ion continuity, momentum and energy equations were solved for the plasma flow along the closed magnetic field lines. During the initial stage of the supersonic outflow in the equatorial region, the ions cool substantially. Using the hydrodynamic model for the large-scale plasma flow, the dynamics of shocks was examined which form in the geomagnetic flux tubes during the early stages of refilling. These shocks are more like those forming in neutral gases than the electrostatic shocks driven by microinstabilities involving ion-ion interaction. Therefore, the shocks seen in the hydrodynamic model are termed as hydrodynamic shocks. Such shocks are generally unsteady and therefore the usual shock jump conditions given by Rankine-Hugoniot relations are not strictly applicable to them. The density, flow velocity and temperature structures associated with the shocks are examined for both asymmetrical and symmetrical flows. In the asymmetrical flow the outflow from one of two conjugate ionospheres is dominant. On the other hand, in the symmetrical case outflows from the two ionospheric sources are identical. Both cases are treated by a two-stream model. In the late type of flow, the early-time refilling shows a relaxation type of oscillation, which is driven by the large-scale interactions between the two identical streams. After this early stage, the resulting temperature structure shows some interesting features. In the equatorial region the streams are isothermal, but in the off-equatorial regions the streams have quite different temperatures, and also densities and flow velocities. The dense and slow stream is found to be warmer than the low-density fast stream. In the late stage of refilling, the temperature is found to steadily increase from the conjugate ionospheres towards the equator; the equatorial temperature is found to be as high as about 8000 K compared to the ionospheric temperature of 3600 K.
Semi-automatic assessment of skin capillary density: proof of principle and validation.
Gronenschild, E H B M; Muris, D M J; Schram, M T; Karaca, U; Stehouwer, C D A; Houben, A J H M
2013-11-01
Skin capillary density and recruitment have been proven to be relevant measures of microvascular function. Unfortunately, the assessment of skin capillary density from movie files is very time-consuming, since this is done manually. This impedes the use of this technique in large-scale studies. We aimed to develop a (semi-) automated assessment of skin capillary density. CapiAna (Capillary Analysis) is a newly developed semi-automatic image analysis application. The technique involves four steps: 1) movement correction, 2) selection of the frame range and positioning of the region of interest (ROI), 3) automatic detection of capillaries, and 4) manual correction of detected capillaries. To gain insight into the performance of the technique, skin capillary density was measured in twenty participants (ten women; mean age 56.2 [42-72] years). To investigate the agreement between CapiAna and the classic manual counting procedure, we used weighted Deming regression and Bland-Altman analyses. In addition, intra- and inter-observer coefficients of variation (CVs), and differences in analysis time were assessed. We found a good agreement between CapiAna and the classic manual method, with a Pearson's correlation coefficient (r) of 0.95 (P<0.001) and a Deming regression coefficient of 1.01 (95%CI: 0.91; 1.10). In addition, we found no significant differences between the two methods, with an intercept of the Deming regression of 1.75 (-6.04; 9.54), while the Bland-Altman analysis showed a mean difference (bias) of 2.0 (-13.5; 18.4) capillaries/mm(2). The intra- and inter-observer CVs of CapiAna were 2.5% and 5.6% respectively, while for the classic manual counting procedure these were 3.2% and 7.2%, respectively. Finally, the analysis time for CapiAna ranged between 25 and 35min versus 80 and 95min for the manual counting procedure. We have developed a semi-automatic image analysis application (CapiAna) for the assessment of skin capillary density, which agrees well with the classic manual counting procedure, is time-saving, and has a better reproducibility as compared to the classic manual counting procedure. As a result, the use of skin capillaroscopy is feasible in large-scale studies, which importantly extends the possibilities to perform microcirculation research in humans. © 2013.
Quantitative nailfold video capillaroscopy in patients with idiopathic inflammatory myopathy.
Mercer, Louise K; Moore, Tonia L; Chinoy, Hector; Murray, Andrea K; Vail, Andy; Cooper, Robert G; Herrick, Ariane L
2010-09-01
To quantify nailfold capillary density and dimensions in patients with idiopathic inflammatory myopathy (IIM) and compare them with those in healthy controls; to look for associations with microvascular disease in IIM; and to determine whether nailfold capillary density and dimensions change over time. Nailfold video microscopy (x300 magnification) was performed on 24 patients with IIM and 35 healthy controls. Capillary density and dimensions (total width and apical width) were quantified. Patients were clinically assessed and disease activity recorded using the Myositis Disease Activity Assessment Tool. Disease severity and physical function were assessed using the myositis damage index and Stanford HAQ, respectively. Findings were analysed using linear and logistic regression, adjusted for age and sex. In a subgroup of 16 patients with IIM and 27 controls, the process was repeated 6-12 months later and the results were analysed using Student's t-test. Capillary density was lower and dimensions were higher in patients with IIM compared with healthy controls (P < 0.001 for all). Anti-Jo-1 antibody was associated with reduced capillary density. In the longitudinal cohort, the mean change in capillary density was -1.4 in patients vs -0.4 in controls (P = 0.07). Mean change in capillary dimensions did not differ between patients and controls, but some patients demonstrated pronounced changes in capillary morphology over time. Reduced capillary density and increased dimensions in patients with IIM can be quantified using nailfold capillaroscopy, suggesting that nailfold capillaroscopy may be useful as an outcome measure of microvascular disease in studies of IIM.
Instiaty, Insti; Lindegardh, Niklas; Jittmala, Podjanee; Hanpithakpong, Warunee; Blessborn, Daniel; Pukrittayakamee, Sasithon; White, Nicholas J.
2013-01-01
Oseltamivir and oseltamivir carboxylate concentrations were measured in venous plasma, venous blood, and capillary blood taken simultaneously from 24 healthy volunteers. Median (range) venous-blood-to-plasma ratios were 1.42 (0.920 to 1.97) for oseltamivir and 0.673 (0.564 to 0.814) for oseltamivir carboxylate. Capillary blood/venous plasma ratios were 1.32 (0.737 to 3.16) for oseltamivir and 0.685 (0.502 to 1.34) for oseltamivir carboxylate. Oseltamivir concentrations in venous and capillary blood were similar. Oseltamivir carboxylate showed a time-dependent distribution between venous and capillary blood. PMID:23507284
ALTO, BARRY W.; JULIANO, STEVEN A.
2008-01-01
We investigated how temperature and precipitation regime encountered over the life cycle of Aedes albopictus (Skuse) affects populations. Caged populations of A. albopictus were maintained at 22, 26, and 30°C. Cages were equipped with containers that served as sites for oviposition and larval development. All cages were assigned to one of three simulated precipitation regimes: (1) low fluctuation regime - water within the containers was allowed to evaporate to 90% of its maximum before being refilled, (2) high fluctuation regime - water was allowed to evaporate to 25% of its maximum before being refilled, and (3) drying regime - water was allowed to evaporate to complete container dryness before being refilled. Greater temperature and the absence of drying resulted in greater production of adults. Greater temperature in combination with drying were detrimental to adult production. These precipitation effects on adult production were absent at 22°C. Greater temperatures and drying treatments yielded higher and lower eclosion rates, respectively and, both yielded greater mortality. Development time and size of adults decreased with increased temperatures, and drying produced larger adults. Greater temperatures resulted in greater egg mortality. These results suggest that populations occurring in warmer regions are likely to produce more adults as long as containers do not dry completely. Populations in cooler regions are likely to produce fewer adults with the variability of precipitation contributing less to variation in adult production. Predicted climate change in North America is likely to extend the northern distribution of A. albopictus and to limit further its establishment in arid regions. PMID:11580037
Water relations in silver birch during springtime: How is sap pressurised?
Hölttä, T; Dominguez Carrasco, M D R; Salmon, Y; Aalto, J; Vanhatalo, A; Bäck, J; Lintunen, A
2018-05-06
Positive sap pressures are produced in the xylem of birch trees in boreal conditions during the time between the thawing of the soil and bud break. During this period, xylem embolisms accumulated during wintertime are refilled with water. The mechanism for xylem sap pressurization and its environmental drivers are not well known. We measured xylem sap flow, xylem sap pressure, xylem sap osmotic concentration, xylem and whole stem diameter changes, and stem and root non-structural carbohydrate concentrations, along with meteorological conditions at two sites in Finland during and after the sap pressurisation period. The diurnal dynamics of xylem sap pressure and sap flow during the sap pressurisation period varied, but were more often opposite to the diurnal pattern after bud burst, i.e. sap pressure increased and sap flow rate mostly decreased when temperature increased. Net conversion of soluble sugars to starch in the stem and roots occurred during the sap pressurisation period. Xylem sap osmotic pressure was small in comparison to total sap pressure, and it did not follow changes in environmental conditions or tree water relations. Based on these findings, we suggest that xylem sap pressurisation and embolism refilling occur gradually over a few weeks through water transfer from parenchyma cells to xylem vessels during daytime, and then the parenchyma are refilled mostly during nighttime by water uptake from soil. Possible drivers for water transfer from parenchyma cells to vessels are discussed. Also the functioning of thermal dissipation probes in conditions of changing stem water content is discussed. © 2018 German Society for Plant Sciences and The Royal Botanical Society of the Netherlands.
A remotely operated drug delivery system with an electrolytic pump and a thermo-responsive valve
Yi, Ying; Zaher, Amir; Yassine, Omar; Kosel, Jurgen; Foulds, Ian G.
2015-01-01
Implantable drug delivery devices are becoming attractive due to their abilities of targeted and controlled dose release. Currently, two important issues are functional lifetime and non-controlled drug diffusion. In this work, we present a drug delivery device combining an electrolytic pump and a thermo-responsive valve, which are both remotely controlled by an electromagnetic field (40.5 mT and 450 kHz). Our proposed device exhibits a novel operation mechanism for long-term therapeutic treatments using a solid drug in reservoir approach. Our device also prevents undesired drug liquid diffusions. When the electromagnetic field is on, the electrolysis-induced bubble drives the drug liquid towards the Poly (N-Isopropylacrylamide) (PNIPAM) valve that consists of PNIPAM and iron micro-particles. The heat generated by the iron micro-particles causes the PNIPAM to shrink, resulting in an open valve. When the electromagnetic field is turned off, the PNIPAM starts to swell. In the meantime, the bubbles are catalytically recombined into water, reducing the pressure inside the pumping chamber, which leads to the refilling of the fresh liquid from outside the device. A catalytic reformer is included, allowing more liquid refilling during the limited valve's closing time. The amount of body liquid that refills the drug reservoir can further dissolve the solid drug, forming a reproducible drug solution for the next dose. By repeatedly turning on and off the electromagnetic field, the drug dose can be cyclically released, and the exit port of the device is effectively controlled. PMID:26339328
Brownian motion of massive black hole binaries and the final parsec problem
NASA Astrophysics Data System (ADS)
Bortolas, E.; Gualandris, A.; Dotti, M.; Spera, M.; Mapelli, M.
2016-09-01
Massive black hole binaries (BHBs) are expected to be one of the most powerful sources of gravitational waves in the frequency range of the pulsar timing array and of forthcoming space-borne detectors. They are believed to form in the final stages of galaxy mergers, and then harden by slingshot ejections of passing stars. However, evolution via the slingshot mechanism may be ineffective if the reservoir of interacting stars is not readily replenished, and the binary shrinking may come to a halt at roughly a parsec separation. Recent simulations suggest that the departure from spherical symmetry, naturally produced in merger remnants, leads to efficient loss cone refilling, preventing the binary from stalling. However, current N-body simulations able to accurately follow the evolution of BHBs are limited to very modest particle numbers. Brownian motion may artificially enhance the loss cone refilling rate in low-N simulations, where the binary encounters a larger population of stars due its random motion. Here we study the significance of Brownian motion of BHBs in merger remnants in the context of the final parsec problem. We simulate mergers with various particle numbers (from 8k to 1M) and with several density profiles. Moreover, we compare simulations where the BHB is fixed at the centre of the merger remnant with simulations where the BHB is free to random walk. We find that Brownian motion does not significantly affect the evolution of BHBs in simulations with particle numbers in excess of one million, and that the hardening measured in merger simulations is due to collisionless loss cone refilling.
A new approach to plasmasphere refilling: Anomalous plasma effects
NASA Technical Reports Server (NTRS)
Singh, N.
1991-01-01
During the last 10 months of the grant, both laminar and anomalous plasma processes occurring during the refilling of the outer plasmasphere after magnetic storms are investigated. Theoretical investigations were based on two types of models: (1) two-stream hydrodynamic model in which plasma flows from the conjugate ionospheres are treated as separate fluids and the ion temperature anisotropies are treated self-consistently; and (2) large-scale particle-in-cell code.
Simulation of German PKL refill/reflood experiment K9A using RELAP4/MOD7. [PWR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hsu, M.T.; Davis, C.B.; Behling, S.R.
This paper describes a RELAP4/MOD7 simulation of West Germany's Kraftwerk Union (KWU) Primary Coolant Loop (PKL) refill/reflood experiment K9A. RELAP4/MOD7, a best-estimate computer program for the calculation of thermal and hydraulic phenomena in a nuclear reactor or related system, is the latest version in the RELAP4 code development series. This study was the first major simulation using RELAP4/MOD7 since its release by the Idaho National Engineering Laboratory (INEL). The PKL facility is a reduced scale (1:134) representation of a typical West German four-loop 1300 MW pressurized water reactor (PWR). A prototypical scale of the total volume to power ratio wasmore » maintained. The test facility was designed specifically for an experiment simulating the refill/reflood phase of a Loss-of-Coolant Accident (LOCA).« less
ERIC Educational Resources Information Center
Wooley, John F.
Capillary suction time is time required for the liquid phase of a treated sludge to travel through 1 centimeter of media (blotter or filter paper). Designed for individuals who have completed National Pollutant Discharge Elimination System (NPDES) level 1 laboratory training skills, this module provides waste water treatment plant operators with…
Early Clinical Features of Dengue Virus Infection in Nicaraguan Children: A Longitudinal Analysis
Biswas, Hope H.; Ortega, Oscar; Gordon, Aubree; Standish, Katherine; Balmaseda, Angel; Kuan, Guillermina; Harris, Eva
2012-01-01
Background Tens of millions of dengue cases and approximately 500,000 life-threatening complications occur annually. New tools are needed to distinguish dengue from other febrile illnesses. In addition, the natural history of pediatric dengue early in illness in a community-based setting has not been well-defined. Methods Data from the multi-year, ongoing Pediatric Dengue Cohort Study of approximately 3,800 children aged 2–14 years in Managua, Nicaragua, were used to examine the frequency of clinical signs and symptoms by day of illness and to generate models for the association of signs and symptoms during the early phase of illness and over the entire course of illness with testing dengue-positive. Odds ratios (ORs) and 95% confidence intervals were calculated using generalized estimating equations (GEE) for repeated measures, adjusting for age and gender. Results One-fourth of children who tested dengue-positive did not meet the WHO case definition for suspected dengue. The frequency of signs and symptoms varied by day of illness, dengue status, and disease severity. Multivariable GEE models showed increased odds of testing dengue-positive associated with fever, headache, retro-orbital pain, myalgia, arthralgia, rash, petechiae, positive tourniquet test, vomiting, leukopenia, platelets ≤150,000 cells/mL, poor capillary refill, cold extremities and hypotension. Estimated ORs tended to be higher for signs and symptoms over the course of illness compared to the early phase of illness. Conclusions Day-by-day analysis of clinical signs and symptoms together with longitudinal statistical analysis showed significant associations with testing dengue-positive and important differences during the early phase of illness compared to the entire course of illness. These findings stress the importance of considering day of illness when developing prediction algorithms for real-time clinical management. PMID:22413033
Padalino, Barbara; Raidal, Sharanne Lee; Carter, Nicole; Celi, Pietro; Muscatello, Gary; Jeffcott, Leo; de Silva, Kumudika
2017-12-01
Horses are transported frequently and often over long distances. Transportation may represent a physiological stressor with consequential health and welfare implications. This study reports the effects of a long distance journey on immunological, clinical, haematological, inflammatory and oxidative parameters in an Experimental Group (EG) of ten horses, comparing them with six horses of similar age and breed used as a non-transported Control Group (CG). Clinical examination and blood sampling were performed twice on all horses: immediately after unloading for the EG, and at rest on the same day for the CG (day 1); at rest on the same day one week later for both groups (day 7). On day 1 EG horses showed increased heart and respiratory rates (P<0.01), rectal temperature (P<0.05), capillary refilling time (P<0.01), neutrophil numbers (P<0.01), serum albumin (P<0.01), plasma total antioxidant status (P<0.01), and a lower rate of mitogen induced proliferation of lymphocytes (P<0.05), in comparison with CG. On day 7 only an increase in total serum protein (P<0.05) and serum globulins (P<0.001) was seen in the EG. No difference in serum cortisol concentration was found. Long distance transportation induced an acute phase response impairing the cell-mediated immune response. Clinical examinations, including assessing CRT and body weight loss, and the monitoring of redox balance may be useful in evaluating the impact of extensive transport events on horses. A better understanding of the link between transportation stress, the immune system and the acute phase response is likely to inform strategies for enhancing the welfare of transported horses. Copyright © 2017 Elsevier Ltd. All rights reserved.
Reliability of Examination Findings in Suspected Community-Acquired Pneumonia.
Florin, Todd A; Ambroggio, Lilliam; Brokamp, Cole; Rattan, Mantosh S; Crotty, Eric J; Kachelmeyer, Andrea; Ruddy, Richard M; Shah, Samir S
2017-09-01
The authors of national guidelines emphasize the use of history and examination findings to diagnose community-acquired pneumonia (CAP) in outpatient children. Little is known about the interrater reliability of the physical examination in children with suspected CAP. This was a prospective cohort study of children with suspected CAP presenting to a pediatric emergency department from July 2013 to May 2016. Children aged 3 months to 18 years with lower respiratory signs or symptoms who received a chest radiograph were included. We excluded children hospitalized ≤14 days before the study visit and those with a chronic medical condition or aspiration. Two clinicians performed independent examinations and completed identical forms reporting examination findings. Interrater reliability for each finding was reported by using Fleiss' kappa (κ) for categorical variables and intraclass correlation coefficient (ICC) for continuous variables. No examination finding had substantial agreement (κ/ICC > 0.8). Two findings (retractions, wheezing) had moderate to substantial agreement (κ/ICC = 0.6-0.8). Nine findings (abdominal pain, pleuritic pain, nasal flaring, skin color, overall impression, cool extremities, tachypnea, respiratory rate, and crackles/rales) had fair to moderate agreement (κ/ICC = 0.4-0.6). Eight findings (capillary refill time, cough, rhonchi, head bobbing, behavior, grunting, general appearance, and decreased breath sounds) had poor to fair reliability (κ/ICC = 0-0.4). Only 3 examination findings had acceptable agreement, with the lower 95% confidence limit >0.4: wheezing, retractions, and respiratory rate. In this study, we found fair to moderate reliability of many findings used to diagnose CAP. Only 3 findings had acceptable levels of reliability. These findings must be considered in the clinical management and research of pediatric CAP. Copyright © 2017 by the American Academy of Pediatrics.
Pealing, Louise; Perel, Pablo; Prieto-Merino, David; Roberts, Ian
2012-01-01
Background Vascular occlusive events can complicate recovery following trauma. We examined risk factors for venous and arterial vascular occlusive events in trauma patients and the extent to which the risk of vascular occlusive events varies with the severity of bleeding. Methods and Findings We conducted a cohort analysis using data from a large international, double-blind, randomised, placebo-controlled trial (The CRASH-2 trial) [1]. We studied the association between patient demographic and physiological parameters at hospital admission and the risk of vascular occlusive events. To assess the extent to which risk of vascular occlusive events varies with severity of bleeding, we constructed a prognostic model for the risk of death due to bleeding and assessed the relationship between risk of death due to bleeding and risk of vascular occlusive events. There were 20,127 trauma patients with outcome data including 204 (1.01%) patients with a venous event (pulmonary embolism or deep vein thrombosis) and 200 (0.99%) with an arterial event (myocardial infarction or stroke). There were 81 deaths due to vascular occlusive events. Increasing age, decreasing systolic blood pressure, increased respiratory rates, longer central capillary refill times, higher heart rates and lower Glasgow Coma Scores (all p<0.02) were strong risk factors for venous and arterial vascular occlusive events. Patients with more severe bleeding as assessed by predicted risk of haemorrhage death had a greatly increased risk for all types of vascular occlusive event (all p<0.001). Conclusions Patients with severe traumatic bleeding are at greatly increased risk of venous and arterial vascular occlusive events. Older age and blunt trauma are also risk factors for vascular occlusive events. Effective treatment of bleeding may reduce venous and arterial vascular occlusive complications in trauma patients. PMID:23251374
Using vital signs to assess children with acute infections: a survey of current practice
Thompson, Matthew; Mayon-White, Richard; Harnden, Anthony; Perera, Rafael; McLeod, Diane; Mant, David
2008-01-01
Background GPs are advised to measure vital signs in children presenting with acute infections. Current evidence supports the value of GPs' overall assessment in determining how unwell a child is, but the additional benefit of measuring vital signs is not known. Aim To describe the vital signs and clinical features that GPs use to assess children (aged <5 years) with acute infections. Design of study Questionnaire survey. Setting All 210 GP principals working within a 10 mile radius of Oxford, UK. Method Data were collected on reported frequency, methods, and utility of measuring vital signs. Description of clinical features was used to assess the overall severity of illness. Results One hundred and sixty-two (77%) GPs responded. Half (54%, 95% confidence interval [CI] = 47 to 62) measured temperature at least weekly, compared to pulse (21%, 95% CI = 15 to 27), and respiratory rates (17%, 95% CI = 11 to 23). Almost half of GPs (77, 48%) never measured capillary refill time. Temperature was measured most frequently using electronic aural thermometers (131/152; 86%); auscultation or counting were used for pulse and respiratory rates. A minority used pulse oximeters to assess respiratory status (30/151, 20%). GPs' thresholds for tachypnoea were similar to published values, but there was no consensus on the threshold of tachycardia. Observations of behaviour and activity were considered more useful than vital signs in assessing severity of illness. Conclusion Vital signs are uncommonly measured in children in general practice and are considered less useful than observation in assessing the severity of illness. If measurement of vital signs is to become part of standard practice, the issues of inaccurate measurement and diagnostic value need to be addressed urgently. PMID:18494174
Using vital signs to assess children with acute infections: a survey of current practice.
Thompson, Matthew; Mayon-White, Richard; Harnden, Anthony; Perera, Rafael; McLeod, Diane; Mant, David
2008-04-01
GPs are advised to measure vital signs in children presenting with acute infections. Current evidence supports the value of GPs' overall assessment in determining how unwell a child is, but the additional benefit of measuring vital signs is not known. To describe the vital signs and clinical features that GPs use to assess children (aged <5 years) with acute infections. Questionnaire survey. All 210 GP principals working within a 10 mile radius of Oxford, UK. Data were collected on reported frequency, methods, and utility of measuring vital signs. Description of clinical features was used to assess the overall severity of illness. One hundred and sixty-two (77%) GPs responded. Half (54%, 95% confidence interval [CI] = 47 to 62) measured temperature at least weekly, compared to pulse (21%, 95% CI = 15 to 27), and respiratory rates (17%, 95% CI = 11 to 23). Almost half of GPs (77, 48%) never measured capillary refill time. Temperature was measured most frequently using electronic aural thermometers (131/152; 86%); auscultation or counting were used for pulse and respiratory rates. A minority used pulse oximeters to assess respiratory status (30/151, 20%). GPs' thresholds for tachypnoea were similar to published values, but there was no consensus on the threshold of tachycardia. Observations of behaviour and activity were considered more useful than vital signs in assessing severity of illness. Vital signs are uncommonly measured in children in general practice and are considered less useful than observation in assessing the severity of illness. If measurement of vital signs is to become part of standard practice, the issues of inaccurate measurement and diagnostic value need to be addressed urgently.
How well do vital signs identify children with serious infections in paediatric emergency care?
Thompson, M; Coad, N; Harnden, A; Mayon-White, R; Perera, R; Mant, D
2009-11-01
To determine whether vital signs identify children with serious infections, and to compare their diagnostic value with that of the Manchester triage score (MTS) and National Institute for Health and Clinical Excellence (NICE) traffic light system of clinical risk factors. Prospective cohort of children presenting with suspected acute infection. We recorded vital signs, level of consciousness, activity level, respiratory distress, hydration and MTS category. Paediatric assessment unit at a teaching hospital in England. 700 children (median age 3 years), of whom 357 (51.0%) were referred from primary care, 198 (28.3%) self-referrals and 116 (16.6%) emergency ambulance transfers. Just over half (383 or 54.7%) were admitted. Severity of infection categorised as serious, intermediate, minor or not infection. Children with serious or intermediate infections (n = 313) were significantly more likely than those with minor or no infection (n = 387) to have a temperature >or=39 degrees C, tachycardia, saturations
Measurement of Capillary Radius and Contact Angle within Porous Media.
Ravi, Saitej; Dharmarajan, Ramanathan; Moghaddam, Saeed
2015-12-01
The pore radius (i.e., capillary radius) and contact angle determine the capillary pressure generated in a porous medium. The most common method to determine these two parameters is through measurement of the capillary pressure generated by a reference liquid (i.e., a liquid with near-zero contact angle) and a test liquid. The rate of rise technique, commonly used to determine the capillary pressure, results in significant uncertainties. In this study, we utilize a recently developed technique for independently measuring the capillary pressure and permeability to determine the equivalent minimum capillary radii and contact angle of water within micropillar wick structures. In this method, the experimentally measured dryout threshold of a wick structure at different wicking lengths is fit to Darcy's law to extract the maximum capillary pressure generated by the test liquid. The equivalent minimum capillary radii of different wick geometries are determined by measuring the maximum capillary pressures generated using n-hexane as the working fluid. It is found that the equivalent minimum capillary radius is dependent on the diameter of pillars and the spacing between pillars. The equivalent capillary radii of micropillar wicks determined using the new method are found to be up to 7 times greater than the current geometry-based first-order estimates. The contact angle subtended by water at the walls of the micropillars is determined by measuring the capillary pressure generated by water within the arrays and the measured capillary radii for the different geometries. This mean contact angle of water is determined to be 54.7°.
Horká, Marie; Karásek, Pavel; Salplachta, Jiří; Růžička, Filip; Vykydalová, Marie; Kubesová, Anna; Dráb, Vladimír; Roth, Michal; Slais, Karel
2013-07-25
In this study, combination of capillary isoelectric focusing (CIEF) in tapered fused silica (FS) capillary with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is presented as an efficient approach for unambiguous identification of probiotic bacteria in real sample. For this purpose, bacteria within genus Lactobacillus were selected as model bioanalytes and cow's milk was selected as a biological sample. CIEF analysis of both the cultivated bacteria and the bacteria in the milk was optimized and isoelectric points characterizing the examined bacteria were subsequently determined independently of the bacterial sample origin. The use of tapered FS capillary significantly enhanced the separation capacity and efficiency of the CIEF analyses performed. In addition, the cell number injected into the tapered FS capillary was quantified and an excellent linearity of the calibration curves was achieved which enabled quantitative analysis of the bacteria by CIEF with UV detection. The minimum detectable number of bacterial cells was 2×10(6) mL(-1). Finally, cow's milk spiked with the selected bacterium was analyzed by CIEF in tapered FS capillary, the focused and detected bacterial cells were collected from the capillary, deposited onto the cultivation medium, and identified using MALDI-TOF MS afterward. Our results have revealed that the proposed procedure can be advantageously used for unambiguous identification of probiotic bacteria in a real sample. Copyright © 2013 Elsevier B.V. All rights reserved.
40 CFR Table 9 to Subpart Jjj of... - Routine Reports Required by This Subpart
Code of Federal Regulations, 2010 CFR
2010-07-01
... days after the end of each 6-month period. See § 63.1335(e)(6)(i) for the due date for the first report... months of making the determination. a There may be two versions of this report due at different times.... § 63.1335(e)(7)(i) Storage Vessels Notification of Inspection At least 30 days prior to the refilling...
40 CFR Table 9 to Subpart Jjj of... - Routine Reports Required by This Subpart
Code of Federal Regulations, 2011 CFR
2011-07-01
... days after the end of each 6-month period. See § 63.1335(e)(6)(i) for the due date for the first report... months of making the determination. a There may be two versions of this report due at different times.... § 63.1335(e)(7)(i) Storage Vessels Notification of Inspection At least 30 days prior to the refilling...
40 CFR Table 9 to Subpart Jjj of... - Routine Reports Required by This Subpart
Code of Federal Regulations, 2012 CFR
2012-07-01
... days after the end of each 6-month period. See § 63.1335(e)(6)(i) for the due date for the first report... months of making the determination. a There may be two versions of this report due at different times.... § 63.1335(e)(7)(i) Storage Vessels Notification of Inspection At least 30 days prior to the refilling...
The effects of capillary transit time heterogeneity (CTH) on brain oxygenation
Angleys, Hugo; Østergaard, Leif; Jespersen, Sune N
2015-01-01
We recently extended the classic flow–diffusion equation, which relates blood flow to tissue oxygenation, to take capillary transit time heterogeneity (CTH) into account. Realizing that cerebral oxygen availability depends on both cerebral blood flow (CBF) and capillary flow patterns, we have speculated that CTH may be actively regulated and that changes in the capillary morphology and function, as well as in blood rheology, may be involved in the pathogenesis of conditions such as dementia and ischemia-reperfusion injury. The first extended flow–diffusion equation involved simplifying assumptions which may not hold in tissue. Here, we explicitly incorporate the effects of oxygen metabolism on tissue oxygen tension and extraction efficacy, and assess the extent to which the type of capillary transit time distribution affects the overall effects of CTH on flow–metabolism coupling reported earlier. After incorporating tissue oxygen metabolism, our model predicts changes in oxygen consumption and tissue oxygen tension during functional activation in accordance with literature reports. We find that, for large CTH values, a blood flow increase fails to cause significant improvements in oxygen delivery, and can even decrease it; a condition of malignant CTH. These results are found to be largely insensitive to the choice of the transit time distribution. PMID:25669911
Blais, Lucie; Vilain, Anne; Kettani, Fatima-Zohra; Forget, Amélie; Lalonde, Geneviève; Beauchesne, Marie-France; Ducharme, Francine M; Lemière, Catherine
2014-01-01
Objectives and hypotheses Adherence to inhaled corticosteroids (ICS) is a major issue in asthma. This study aimed to estimate the accuracy of the days’ supply and number of refills allowed, variables recorded in Québec claims databases and used to estimate adherence, and to develop correction factors, if required. We hypothesised that the accuracy of the days’ supply for ICS would be low whereas the accuracy of the number of refills allowed would be high. Setting 40 community pharmacies in Québec (Canada) and a medication registry. Participants We collected data for 1108 ICS original prescriptions stored in the 40 pharmacies (sample 1), and we obtained a second sample of 2676 ICS prescriptions selected from reMed, a medication registry (sample 2). Primary and secondary outcomes We estimated the concordance of the days’ supply and number of refills between Québec claims databases and the original prescription from sample 1. We developed a correction factor for the days’ supply in sample 1 and validated it in sample 2. Analyses were stratified by age: 0–11 and 12–64 years. Results In sample 1, the concordance for the days’ supply was 39.6% (95% CI 37.6% to 41.6%) in those aged 0–11 years and 56% (54.9% to 57.2%) in those aged 12–64 years. The concordance increased to 59.4% (58.2% to 60.5%) in those aged 0–11 years and 74.2% (73.5% to 74.9%) in those aged 12–64 years after applying the correction factors in sample 2. The concordance for the refills allowed was 92.1% (91% to 93.1%) in those aged 0–11 years and 93.1% (92.5% to 93.7%) in those aged 12–64 years in sample 1. Conclusions The accuracy of the days’ supply was moderate among those aged 0–11 years and substantial among those aged 12–64 years after applying the correction factors. The accuracy of the number of refills was almost perfect in both groups. PMID:25432902
Haak, Carol E; Rudloff, Elke; Kirby, Rebecca
2012-04-01
To compare the use of polymerized stroma-free bovine hemoglobin (Hb-200) and 6% hetastarch 450/0.7 (HES 450/0.7) in 0.9% saline during fluid resuscitation of dogs with gastric dilatation-volvulus (GDV). Prospective, randomized clinical case series. Private specialty and referral clinic. Twenty client-owned dogs presenting with GDV. Dogs presenting with GDV and abnormal perfusion parameters first received rapid IV infusion of a buffered isotonic replacement crystalloid (15 mL/kg) and IV opioids. Patients were then randomized to receive either Hb-200 (N = 10) or HES 450/0.7 (N = 10). Balanced isotonic replacement crystalloids (10-20 mL/kg IV) were rapidly infused along with either Hb-200 or HES in 5 mL/kg IV aliquots to meet resuscitation end points. Resuscitation was defined as meeting at least 2 of 3 criteria: (1) capillary refill time 1-2 seconds, pink mucous membrane color, strong femoral pulse quality; (2) heart rate (HR) ≤ 150/min; or (3) indirect arterial systolic blood pressure (SBP) > 90 mm Hg. HR, SBP, packed cell volume, hemoglobin, glucose, venous pH, bicarbonate, base excess, anion gap, and colloid osmotic pressure were compared at hospital entry and within 30 minutes post-resuscitation. Compared to the HES group, the Hb-200 group required significantly less colloid (4.2 versus 18.4 mL/kg) and crystalloid (31.3 versus 48.1 mL/kg) to reach resuscitation end points (P = 0.001). Time to resuscitation was significantly shorter in the Hb-200 group (12.5 versus 52.5 min). Dogs with GDV receiving Hb-200 during initial resuscitation required smaller volumes of both crystalloid and colloid fluids and reached resuscitation end points faster than dogs receiving HES 450/0.7 (P = 0.02). © Veterinary Emergency and Critical Care Society 2012.
Dickerson, Jane A.; Dovichi, Norman J.
2011-01-01
We perform two-dimensional capillary electrophoresis on fluorescently labeled proteins and peptides. Capillary sieving electrophoresis was performed in the first dimension and micellar electrokinetic capillary chromatography was performed in the second. A cellular homogenate was labeled with the fluorogenic reagent FQ and separated using the system. This homogenate generated a pair of ridges; the first had essentially constant migration time in the CSE dimension, while the second had essentially constant migration time in the MEKC dimension. In addition a few spots were scattered through the electropherogram. The same homogenate was digested using trypsin, and then labeled and subjected to the two dimensional separation. In this case, the two ridges observed from the original two-dimensional separation disappeared, and were replaced by a set of spots that fell along the diagonal. Those spots were identified using a local-maximum algorithm and each was fit using a two-dimensional Gaussian surface by an unsupervised nonlinear least squares regression algorithm. The migration times of the tryptic digest components were highly correlated (r = 0.862). When the slowest migrating components were eliminated from the analysis, the correlation coefficient improved to r = 0.956. PMID:20564272
NASA Astrophysics Data System (ADS)
Obana, Y.; Maruyama, N.; Masahito, N.; Matsuoka, A.; Teramoto, M.; Nomura, R.; Fujimoto, A.; Tanaka, Y.; Shinohara, M.; Kasahara, Y.; Matsuda, S.; Kumamoto, A.; Tsuchiya, F.; Yoshizumi, M.; Shinohara, I.
2017-12-01
Earth's inner magnetosphere is a complex dynamical region of geo space comprising plasma populations with wide energy ranges, the plasmasphere, ring current, and radiation belts. They form a closely coupled system, thus, the plasmasphere is the lowest energy population in the inner magnetosphere, but the accurate prediction of the evolution of the plasmasphere is critical in understanding the dynamics of the inner magnetosphere, which include even the highest energy population, the radiation belts. In this study, we study plasmaspheric refilling following geomagnetic storms using data from ERG-MGF, ERG-PWE, RBSP-EMFISIS and Ground-based magnetometers. DC magnetic field data measured by ERG-MGF, RBSP-EMFISIS and ground-based magnetometers provides the frequency of the toroidal mode field line resonances. From this information, the equatorial plasma mass density is estimated by solving the MHD wave equation for suitable models of the magnetic field and the field line density distribution. ERG-PWE and RBSP-EMFISIS provide measurements of wave electric and magnetic field, thus we can estimate the local electron density from the plasma wave spectrograms by identifying narrow-band emission at the upper-hybrid resonance frequency. Furthermore, using Ionosphere Plasmasphere Electrodynamics Model (IPE), we calculate the plasmaspheric refilling rates and evaluate the relative contribution of various mechanisms (heating, neutral particle density, composition and wings, etc.) to the refilling rate.
Yang, Shi-Jian; Zhang, Yong-Jiang; Sun, Mei; Goldstein, Guillermo; Cao, Kun-Fang
2012-04-01
Despite considerable investigations of diurnal water use characteristics in different plant functional groups, the research on daily water use strategies of woody bamboo grasses remains lacking. We studied the daily water use and gas exchange of Sinarundinaria nitida (Mitford) Nakai, an abundant subtropical bamboo species in Southwest China. We found that the stem relative water content (RWC) and stem hydraulic conductivity (K(s)) of this bamboo species did not decrease significantly during the day, whereas the leaf RWC and leaf hydraulic conductance (K(leaf)) showed a distinct decrease at midday, compared with the predawn values. Diurnal loss of K(leaf) was coupled with a midday decline in stomatal conductance (g(s)) and CO(2) assimilation. The positive root pressures in the different habitats were of sufficient magnitude to refill the embolisms in leaves. We concluded that (i) the studied bamboo species does not use stem water storage for daily transpiration; (ii) diurnal down-regulation in K(leaf) and gs has the function to slow down potential water loss in stems and protect the stem hydraulic pathway from cavitation; (iii) since K(leaf) did not recover during late afternoon, refilling of embolism in bamboo leaves probably fully depends on nocturnal root pressure. The embolism refilling mechanism by root pressure could be helpful for the growth and persistence of this woody monocot species.
Unusual refilling of the slot region between the Van Allen radiation belts
NASA Astrophysics Data System (ADS)
Yang, X.; Yu, J.; Ni, B.; Zhang, Y.; Zhang, X.
2017-12-01
Using multi-satellite measurements, the dynamics of relativistic electrons in the slot region are investigated from 2000 to 2011. The dependences of relativistic electron enhancements in the slot region on interplanetary and magnetospheric conditions are researched. It is resulted that the relativistic electron enhancements in the slot region occurred under remarkable interplanetary and magnetospheric conditions. A uniquely strong and long-lived relativistic electron slot region refilling event from November 2004 to January 2005 is studied especially. Both empirically modeled and observationally estimated plasmapause locations demonstrate that the plasmasphere eroded significantly prior to the enhancement phase of this event. The estimated diffusion coefficients indicate that the radial diffusion due to ULF waves is insufficient to account for the observed enhancement of slot region electrons. However, the diffusion coefficients evaluated using the distribution of chorus wave intensities derived from low-altitude POES electron observations indicate that the local acceleration induced by chorus could account for the major feature of observed enhancement outside the plasmapause. When the plasmasphere recovered, the refilled slot region was enveloped inside the plasmapause. In the plasmasphere, while the efficiency of hiss scattering loss increases by including unusually low frequency hiss waves, the interaction with hiss alone cannot fully explain the decay of this event, especially at higher energies, which suggests that EMIC waves contribute to the relativistic electron loss process at such low L-shells for this refilling event.
Xu, Liang; Cui, Pengfei; Wang, Dongmei; Tang, Cheng; Dong, Linyi; Zhang, Can; Duan, Hongquan; Yang, Victor C
2014-01-03
In this study, poly(glycidyl methacrylate) (PGMA) nanoparticles (NPs) were prepared and chemically immobilized for the first time onto a capillary inner wall for open tubular capillary electrochromatography (OTCEC). The immobilization of PGMA NPs onto the capillary was attained by a ring-opening reaction between the NPs and an amino-silylated fused capillary inner surface. Scanning electron micrographs clearly demonstrated that the NPs were bound to the capillary inner surface in a dense monolayer. The PGMA NP-coated column was then functionalized by lysine (Lys). After fuctionalization, the capillary can afford strong anodic electroosmotic flow, especially in acidic running buffers. Separations of three amino acids (including tryptophan, tyrosine and phenylalanine) were performed in NP-modified, monolayer Lys-functionalized and bare uncoated capillaries. Results indicated that the NP-coated column can provide more retention and higher resolution for analytes due to the hydrophobic interaction between analytes and the NP-coating. Run-to-run and column-to-column reproducibilities in the separation of the amino acids using the NP-modified column were also demonstrated. Copyright © 2013 Elsevier B.V. All rights reserved.
Modeling capillary bridge dynamics and crack healing between surfaces of nanoscale roughness
NASA Astrophysics Data System (ADS)
Soylemez, Emrecan; de Boer, Maarten P.
2017-12-01
Capillary bridge formation between adjacent surfaces in humid environments is a ubiquitous phenomenon. It strongly influences tribological performance with respect to adhesion, friction and wear. Only a few studies, however, assess effects due to capillary dynamics. Here we focus on how capillary bridge evolution influences crack healing rates. Experimental results indicated a logarithmic decrease in average crack healing velocity as the energy release rate increases. Our objective is to model that trend. We assume that capillary dynamics involve two mechanisms: capillary bridge growth and subsequently nucleation followed by growth. We show that by incorporating interface roughness details and the presence of an adsorbed water layer, the behavior of capillary force dynamics can be understood quantitatively. We identify three important regimes that control the healing process, namely bridge growth, combined bridge growth and nucleation, and finally bridge nucleation. To fully capture the results, however, the theoretical model for nucleation time required an empirical modification. Our model enables significant insight into capillary bridge dynamics, with a goal of attaining a predictive capability for this important microelectromechanical systems (MEMS) reliability failure mechanism.
Nucleation time of nanoscale water bridges.
Szoszkiewicz, Robert; Riedo, Elisa
2005-09-23
Water capillaries bind together grains of sand. They also can bind an atomic force microscope tip to a substrate. The kinetics of capillary condensation at the nanoscale is studied here using friction force microscopy. At 40% relative humidity we find that the meniscus nucleation times increase from 0.7 to 4.2 ms when the temperature decreases from 332 to 299 K. The nucleation times grow exponentially with the inverse temperature 1/T obeying an Arrhenius law. We obtain a nucleation energy barrier of 7.8 x 10(-20) J and an attempt frequency ranging between 4 and 250 GHz, in excellent agreement with theoretical predictions. These results provide direct experimental evidence that capillary condensation is a thermally activated phenomenon.
El-Khatib, Ziad; Katzenstein, David; Marrone, Gaetano; Laher, Fatima; Mohapi, Lerato; Petzold, Max; Morris, Lynn; Ekström, Anna Mia
2011-01-01
Background Affordable strategies to prevent treatment failure on first-line regimens among HIV patients are essential for the long-term success of antiretroviral therapy (ART) in sub-Saharan Africa. WHO recommends using routinely collected data such as adherence to drug-refill visits as early warning indicators. We examined the association between adherence to drug-refill visits and long-term virologic and immunologic failure among non-nucleoside reverse transcriptase inhibitor (NNRTI) recipients in South Africa. Methods In 2008, 456 patients on NNRTI-based ART for a median of 44 months (range 12–99 months; 1,510 person-years) were enrolled in a retrospective cohort study in Soweto. Charts were reviewed for clinical characteristics before and during ART. Multivariable logistic regression and Kaplan-Meier survival analysis assessed associations with virologic (two repeated VL>50 copies/ml) and immunologic failure (as defined by WHO). Results After a median of 15 months on ART, 19% (n = 88) and 19% (n = 87) had failed virologically and immunologically respectively. A cumulative adherence of <95% to drug-refill visits was significantly associated with both virologic and immunologic failure (p<0.01). In the final multivariable model, risk factors for virologic failure were incomplete adherence (OR 2.8, 95%CI 1.2–6.7), and previous exposure to single-dose nevirapine or any other antiretrovirals (adj. OR 2.1, 95%CI 1.2–3.9), adjusted for age and sex. In Kaplan-Meier analysis, the virologic failure rate by month 48 was 19% vs. 37% among adherent and non-adherent patients respectively (logrank p value = 0.02). Conclusion One in five failed virologically after a median of 15 months on ART. Adherence to drug-refill visits works as an early warning indicator for both virologic and immunologic failure. PMID:21408071
Refilling the plasmasphere through the exospheric sieve
NASA Astrophysics Data System (ADS)
Krall, J.; Huba, J.; Emmert, J. T.
2016-12-01
The ability to compute plasmasphere densities is critical to many space weather concerns. The sensitivity of refilling to the solar cycle is compelling because, paradoxically, refilling rates are generally lowest when the ionosphere is strongest. In the past, this has been attributed to a dearth of exosphere H at solar maximum. While H is needed to supply H + O+ -> H+ + O charge exchange, recent work demonstrates a significant sensitivity to O [1]. Results will be based on preliminary model-data comparisons using in situ Van Allen Probe EMFISIS data and the SAMI3 ionosphere/plasmasphere code. We will assess the impact of atmospheric composition (i.e., O and H) and solar activity (e.g., F10.7) on plasmasphere refilling rates and density following magnetic storms. SAMI3 (Sami3 is Also a Model of the Ionosphere) is a first-principles ionosphere/plasmasphere model. SAMI3 includes 7 ion species (H+, He+, O+, N+, O2+, N2+, NO+), each treated as a separate fluid, with temperature equations being solved for H+, He+, O+ and e- [2]. SAMI3 uses the empirical MSIS thermosphere/exosphere model to specify O and H densities. SAMI3 includes scaling factors that can be used to tune MSIS densities to bring them in line with measurements of satellite drag. Key inputs for this data-driven modeling are the thermosphere oxygen (O) and hydrogen (H) densities, and the F10.7 proxy for solar ultraviolet irradiance. [1 ]Krall, J., J. T. Emmert, F. Sassi, S. E. McDonald, and J. D. Huba (2016), Day-to-day variability in the thermosphere and its impact on plasmasphere refilling, J. Geophys. Res. Space Physics, 121, doi:10.1002/2015JA022328. [2] Huba, J. and J. Krall (2013), Modeling the plasmasphere with SAMI3, Geophys. Res. Lett., 40, 6-10, doi:10.1029/2012GL054300 Research supported by NRL base funds.
Hall, Aaron C.; Hosking, F. Michael ,; Reece, Mark
2003-06-24
A capillary test specimen, method, and system for visualizing and quantifying capillary flow of liquids under realistic conditions, including polymer underfilling, injection molding, soldering, brazing, and casting. The capillary test specimen simulates complex joint geometries and has an open cross-section to permit easy visual access from the side. A high-speed, high-magnification camera system records the location and shape of the moving liquid front in real-time, in-situ as it flows out of a source cavity, through an open capillary channel between two surfaces having a controlled capillary gap, and into an open fillet cavity, where it subsequently forms a fillet on free surfaces that have been configured to simulate realistic joint geometries. Electric resistance heating rapidly heats the test specimen, without using a furnace. Image-processing software analyzes the recorded images and calculates the velocity of the moving liquid front, fillet contact angles, and shape of the fillet's meniscus, among other parameters.
Laser beam coupling with capillary discharge plasma for laser wakefield acceleration applications
NASA Astrophysics Data System (ADS)
Bagdasarov, G. A.; Sasorov, P. V.; Gasilov, V. A.; Boldarev, A. S.; Olkhovskaya, O. G.; Benedetti, C.; Bulanov, S. S.; Gonsalves, A.; Mao, H.-S.; Schroeder, C. B.; van Tilborg, J.; Esarey, E.; Leemans, W. P.; Levato, T.; Margarone, D.; Korn, G.
2017-08-01
One of the most robust methods, demonstrated to date, of accelerating electron beams by laser-plasma sources is the utilization of plasma channels generated by the capillary discharges. Although the spatial structure of the installation is simple in principle, there may be some important effects caused by the open ends of the capillary, by the supplying channels etc., which require a detailed 3D modeling of the processes. In the present work, such simulations are performed using the code MARPLE. First, the process of capillary filling with cold hydrogen before the discharge is fired, through the side supply channels is simulated. Second, the simulation of the capillary discharge is performed with the goal to obtain a time-dependent spatial distribution of the electron density near the open ends of the capillary as well as inside the capillary. Finally, to evaluate the effectiveness of the beam coupling with the channeling plasma wave guide and of the electron acceleration, modeling of the laser-plasma interaction was performed with the code INF&RNO.
Kubán, Pavel; Kubán, Petr; Kubán, Vlastimil; Hauser, Peter C; Bocek, Petr
2008-05-09
In this paper capillary electrochromatography of alkali and alkaline-earth metal cations in open tubular capillary columns is described. Capillary columns are prepared by coating fused silica capillaries of 75 microm I.D. with poly(butadiene-maleic acid) copolymer (PBMA) in multiple layers. Thermally initiated radical polymerization is used to crosslink the stationary phase. Capillary columns with different number of stationary phase layers can be prepared and allow for the adjustment of separation selectivity in the electrochromatographic mode. Fast and sensitive separations of common inorganic cations are achieved in less than 6 min in a 60 cm capillary column with on-column capacitively coupled contactless conductivity detector. Limits of detection (S/N=3) for the determination of alkali and alkaline-earth metal cations range from 0.3 to 2.5 microM and repeatability is better than 0.5, 4.5 and 6.1% for migration times, peak heights and peak areas, respectively.
Time resolved EUV spectra from Zpinching capillary discharge plasma
NASA Astrophysics Data System (ADS)
Jancarek, Alexandr; Nevrkla, Michal; Nawaz, Fahad
2015-09-01
We developed symmetrically charged driver to obtain high voltage, high current Z-pinching capillary discharge. Plasma is created by up to 70 kA, 29 ns risetime current pulse passing through a 5 mm inner diameter, 224 mm long capillary filled with gas to initial pressure in the range of 1 kPa. Due to the low inductance design of the driver, the pinch is observable directly from the measured current curve. Time-integrated and time-resolved spectra of discharge plasma radiation are recorded together with the capillary current and analyzed. The most encouraging spectra were captured in the wavelength range 8.3 ÷ 14 nm. This spectral region contains nitrogen Balmer series lines including potentially lasing NVII 2 - 3 transition. Spectral lines are identified in the NIST database using the FLY kinetic code. The line of 13.38 nm wavelength, transition NVII 2 - 3, was observed in gated, and also in time-integrated spectra for currents >60 kA. This work has been supported by the Ministry of Education, Youth and Sports of the Czech Republic grants LG13029.
Pulsed electrothermal thruster
NASA Technical Reports Server (NTRS)
Burton, Rodney L. (Inventor); Goldstein, Yeshayahu S. A. (Inventor); Tidman, Derek A. (Inventor); Winsor, Niels K. (Inventor)
1989-01-01
A plasma electrothermal thruster includes a capillary passage in which a plasma discharge is formed and directed out of an open end of the passage into a supersonic nozzle. Liquid supplied to the capillary passage becomes partially atomized to cool a confining surface of the passage. The plasma discharge is formed as the atomized liquid flows out of the open end into a supersonic equilibrium nozzle. The discharge can have a duration greater than the two way travel time of acoustic energy in the capillary to cause the plasma to flow continuously through the nozzle during the time of the discharge pulse.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koizumi, Mitsuo; Oshima, Masumi; Toh, Yosuke
In order to reduce the time and effort of the daily task of refilling Dewar vessels of Ge detectors with liquid nitrogen (LN{sub 2}), we have developed an automatic LN{sub 2} filling system equipped with a LN{sub 2} plant. With this system, we were freed from the work of LN{sub 2} filling. Such an LN{sub 2} filling system is useful for moderate-scale Ge detector arrays consisting of fewer than 20 Ge detectors.
1956-08-10
cables was made end of each working day, all oil cases had to be early in the program. Preliminary estimates of drained, flushed, and refilled. Men...spread footings 4 feet below machine tw e scientific load. Separate rach- grade. However, at each of the two proposed ines were uthe to obtain good...to the cables extending from the termyinal cabinet pro-Itransformer was supplied through an oil fuse vided timing signals for Station 1:336,04
Treelike networks accelerating capillary flow.
Shou, Dahua; Ye, Lin; Fan, Jintu
2014-05-01
Transport in treelike networks has received wide attention in natural systems, oil recovery, microelectronic cooling systems, and textiles. Existing studies are focused on transport behaviors under a constant potential difference (including pressure, temperature, and voltage) in a steady state [B. Yu and B. Li, Phys. Rev. E 73, 066302 (2006); J. Chen, B. Yu, P. Xu, and Y. Li, Phys. Rev. E 75, 056301 (2007)]. However, dynamic (time-dependent) transport in such systems has rarely been concerned. In this work, we theoretically investigate the dynamics of capillary flow in treelike networks and design the distribution of radius and length of local branches for the fastest capillary flow. It is demonstrated that capillary flow in the optimized tree networks is faster than in traditional parallel tube nets under fixed constraints. As well, the flow time of the liquid is found to increase approximately linearly with penetration distance, which differs from Washburn's classic description that flow time increases as the square of penetration distance in a uniform tube.
Duraski, Sylvia A; Sayyad, Anjum
2018-04-01
This article details an unreported potential cause of withdrawal symptoms in a patient with cerebral palsy who experienced intrathecal baclofen withdrawal shortly after placement of a baclofen pump with subsequent refill with Gablofen. Initial implantation of the baclofen pump with Lioresal occurred after a successful hospital trial of intrathecal injection via lumbar puncture. However, later, the patient did experience signs and symptoms of baclofen withdrawal after a pump refill was performed with Gablofen.
Chattman, Marisa; Gerba, Sheri L; Maxwell, Charles P
2011-03-01
The goal of the study discussed in this article was to determine the occurrence of heterotrophic and coliform bacteria in liquid soap from bulk refillable dispensers, obtained from restrooms in a variety of public facilities. A total of 541 samples was collected from five U.S. cities. Liquid soap from dispensers in public areas was found to contain heterotrophic and coliform bacterial numbers averaging more than 106 CFU/mL in 24.8% of the dispensers.
Tavlarides, Lawrence L.; Bae, Jae-Heum
1991-01-01
A laser capillary spectrophotometric technique measures real time or near real time bivariate drop size and concentration distribution for a reactive liquid-liquid dispersion system. The dispersion is drawn into a precision-bore glass capillary and an appropriate light source is used to distinguish the aqueous phase from slugs of the organic phase at two points along the capillary whose separation is precisely known. The suction velocity is measured, as is the length of each slug from which the drop free diameter is calculated. For each drop, the absorptivity at a given wavelength is related to the molar concentration of a solute of interest, and the concentration of given drops of the organic phase is derived from pulse heights of the detected light. This technique permits on-line monitoring and control of liquid-liquid dispersion processes.
NASA Astrophysics Data System (ADS)
Moon, Kang Seok; Choi, Jung Hoon; Choi, Dong-June; Kim, Sun Ho; Hyo Ha, Man; Nam, Hyo-Jin; Kim, Min Soo
2008-12-01
This paper presents a method for analyzing the refill process of a piezoelectric inkjet printing head with a high firing frequency for color filter manufacturing. Theoretical and experimental studies on the equivalent length (Leq) versus jetting characteristics were performed. The new model has shown quantitatively the same result compared with a commercialized simulation code. Also it is identified that the refill time increases with the equivalent liquid length (Leq) because the viscous force increases. The inkjet printing head has been designed with a lumped model analysis and fabricated with a silicon wafer (1 0 0) by a MEMS process. To investigate how the equivalent length (Leq) influences the firing frequency, an experiment was conducted using a stroboscope. In the case of colorant ink, it is possible to eject an ink droplet up to 5 kHz with a 40 pl drop volume. On the other hand, the firing frequency calculated with the new model is about 3 kHz under the condition of the equivalent liquid length (Leq), 250 µm. The difference between the new model and experiment may be a result of a mismatch of initial meniscus position due to the meniscus oscillation. Experimentally the meniscus oscillation is observed through an optical measurement with a visualization apparatus and a transparent nozzle. Hence the efficiency of the new model may be enhanced in a high viscosity range. The methods for increasing the firing frequency are to reduce the equivalent length (Leq) and to modify the ink property. Because the former tends to decrease a viscous loss and the latter tends to increase a viscous damping, two parameters should be combined adequately within an allowable drop volume.
2018-01-01
Background: Patients’ satisfaction is the key parameter to measure the quality of healthcare services. Value added-services (VAS) were introduced to improve the quality of medication deliveries and to reduce the waiting time at outpatient pharmacy. Objective: This study aimed to compare the satisfaction levels of patients receiving VAS and traditional counter service (TCS) for prescription refills in Port Dickson Hospital. Methods: A single-center, cross-sectional study was conducted in the outpatient pharmacy department of Port Dickson Hospital from 1 March to 30 June 2017. Systematic sampling method was utilized to recruit subjects into the study, except mail pharmacy in which universal sampling method was used. Data collection was done via telephone interviews for both groups. Results: There was 104 and 105 in TCS and VAS group respectively. The response rate was 99.5%. Overall, a significant higher total mean satisfaction score in VAS group was observed as compared to TCS group (43.39 versus 40.49, p=0.002). The same finding was observed after confounding factors were controlled (VAS=44.66, 95% CI 43.07:46.24 versus TCS=39.88, 95% CI 38.29:41.46; p<0.001). VAS respondents reported more satisfaction than TCS respondents for both general and technical aspects. Among the VAS offered, mail pharmacy service respondents showed highest total mean satisfaction score, but no significant different was seen between groups (p=0.064). Conclusion: VAS respondents were generally more satisfied than TCS respondents for prescription refills. A longitudinal study is necessary to examine the impact of other dimensions and other types of VAS on patients’ satisfaction levels. PMID:29619135
Wetzels, Gwenn E C; Nelemans, Patricia J; Schouten, Jan S A G; van Wijk, Boris L G; Prins, Martin H
2006-02-10
Poor compliance with antihypertensive medication is assumed to be an important reason for unsatisfactory control of blood pressure. Poor compliance is difficult to detect. Each method of measuring compliance has its own strengths and weaknesses. The aim of the present study was to compare patient compliance with antihypertensive drugs as measured by two methods, electronic monitoring versus refill compliance. 161 patients with a diagnosis of hypertension for at least a year prior to inclusion, and inadequate blood pressure control (systolic blood pressure > or = 160 mmHg and/or diastolic blood pressure > or = 95 mmHg) despite the use of antihypertensive drugs, were included. Patients' pharmacy records from 12 months prior to inclusion were obtained. Refill compliance was calculated as the number of days for which the pills were prescribed divided by the total number of days in this period. After inclusion compliance was measured with an electronic monitor that records time and date of each opening of the pillbox. Agreement between both compliance measures was calculated using Spearman's correlation coefficient and Cohen's kappa coefficient. There was very little agreement between the two measures. Whereas refill compliance showed a large range of values, compliance as measured by electronic monitoring was high in almost all patients with estimates between 90% and 100%. Cohen's kappa coefficient was 0.005. While electronic monitoring is often considered to be the gold standard for compliance measurements, our results suggest that a short-term electronic monitoring period with the patient being aware of electronic monitoring is probably insufficient to obtain valid compliance data. We conclude that there is a strong need for more studies that explore the effect of electronic monitoring on patient's compliance.
NASA Astrophysics Data System (ADS)
Kang, Dong Hun; Yun, Tae Sup
2018-02-01
We propose a new outflow boundary condition to minimize the capillary end effect for a pore-scale CO2 displacement simulation. The Rothman-Keller lattice Boltzmann method with multi-relaxation time is implemented to manipulate a nonflat wall and inflow-outflow boundaries with physically acceptable fluid properties in 2-D microfluidic chip domain. Introducing a mean capillary pressure acting at CO2-water interface to the nonwetting fluid at the outlet effectively prevents CO2 injection pressure from suddenly dropping upon CO2 breakthrough such that the continuous CO2 invasion and the increase of CO2 saturation are allowed. This phenomenon becomes most pronounced at capillary number of logCa = -5.5, while capillary fingering and massive displacement of CO2 prevail at low and high capillary numbers, respectively. Simulations with different domain length in homogeneous and heterogeneous domains reveal that capillary pressure and CO2 saturation near the inlet are reproducible compared with those with a proposed boundary condition. The residual CO2 saturation uniquely follows the increasing tendency with increasing capillary number, corroborated by experimental evidences. The determination of the mean capillary pressure and its sensitivity are also discussed. The proposed boundary condition is commonly applicable to other pore-scale simulations to accurately capture the spatial distribution of nonwetting fluid and corresponding displacement ratio.
Micromechanism linear actuator with capillary force sealing
Sniegowski, Jeffry J.
1997-01-01
A class of micromachine linear actuators whose function is based on gas driven pistons in which capillary forces are used to seal the gas behind the piston. The capillary forces also increase the amount of force transmitted from the gas pressure to the piston. In a major subclass of such devices, the gas bubble is produced by thermal vaporization of a working fluid. Because of their dependence on capillary forces for sealing, such devices are only practical on the sub-mm size scale, but in that regime they produce very large force times distance (total work) values.
Martinez, Homero; Palar, Kartika; Linnemayr, Sebastian; Smith, Alexandria; Derose, Kathryn Pitkin; Ramírez, Blanca; Farías, Hugo; Wagner, Glenn
2014-10-01
Food insecurity and malnutrition negatively affect adherence to antiretroviral therapy (ART) and are associated with poor HIV clinical outcomes. We examined the effect of providing household food assistance and nutrition education on ART adherence. A 12-month prospective clinical trial compared the effect of a monthly household food basket (FB) plus nutrition education (NE) versus NE alone on ART adherence on 400 HIV patients at four clinics in Honduras. Participants had been receiving ART for an average of 3.7 years and were selected because they had suboptimal adherence. Primary outcome measures were missed clinic appointments, delayed prescription refills, and self-reported missed doses of ART. These three adherence measures improved for both groups over 12 months (p < 0.01), mostly within 6 months. On-time prescription refills improved for the FB plus NE group by 19.6 % more than the group receiving NE alone after 6 months (p < 0.01), with no further change at 12 months. Change in missed appointments and self-reported missed ART doses did not significantly differ by intervention group.
Evaluation of the impact of frost resistances on potential altitudinal limit of trees.
Charrier, Guillaume; Cochard, Hervé; Améglio, Thierry
2013-09-01
Winter physiology of woody plants is a key issue in temperate biomes. Here, we investigated different frost resistance mechanisms on 1-year-old branches of 11 European tree species from November until budburst: (i) frost hardiness of living cells (by electrolyte leakage method), (ii) winter embolism sensitivity (by percentage loss of conductivity: PLC) and (iii) phenological variation of budburst (by thermal time to budburst). These ecophysiological traits were analyzed according to the potential altitudinal limit, which is highly related to frost exposure. Seasonal frost hardiness and PLC changes are relatively different across species. Maximal PLC observed in winter (PLCMax) was the factor most closely related to potential altitudinal limit. Moreover, PLCMax was related to the mean hydraulic diameter of vessels (indicating embolism sensitivity) and to osmotic compounds (indicating ability of living cells to refill xylem conducting elements). Winter embolism formation seems to be counterbalanced by active refilling from living cells. These results enabled us to model potential altitudinal limit according to three of the physiological/anatomical parameters studied. Monitoring different frost resistance strategies brings new insights to our understanding of the altitudinal limits of trees.
The plasmasphere electron content paradox
NASA Astrophysics Data System (ADS)
Krall, J.; Huba, J. D.
2016-09-01
Measurements show that plasmasphere refilling rates decrease with increasing solar activity, while paradoxically, the vertical integration of the plasmasphere electron density (pTEC) increases with increasing solar activity. Using the Naval Research Laboratory SAMI2 (Sami2 is Another Model of the Ionosphere) and SAMI3 (Sami3 is Also a Model of the Ionosphere) codes, we simulate plasmasphere refilling following a model storm, reproducing this observed phenomenon. In doing so, we find that the refilling rate and resulting pTEC values are sensitive to the oxygen profile in the thermosphere and exosphere: the supply of H+ in the topside ionosphere is limited by the local O+ density, through H+O+→H++O charge exchange. At solar minimum, the O+ supply simply increases with the O density in the exosphere. At solar maximum, we find that O-O+ collisions limit the O+ density in the topside ionosphere such that it decreases with increasing O density. The paradox occurs because the pTEC metric gives electrons in the topside ionosphere more weight than electrons in the plasmasphere.
NASA Astrophysics Data System (ADS)
Li, Yuandong; Wei, Wei; Li, Chenxi; Wang, Ruikang K.
2017-02-01
We report a novel use of optical coherence tomography (OCT) based angiography to visualize and quantify dynamic response of cerebral capillary flow pattern in mice upon hindpaw electrical stimulation through the measurement of the capillary transit-time heterogeneity (CTH) and capillary mean transit time (MTT) in a wide dynamic range of a great number of vessels in vivo. The OCT system was developed to have a central wavelength of 1310 nm, a spatial resolution of 8 µm and a system dynamic range of 105 dB at an imaging rate of 92 kHz. The mapping of dynamic cerebral microcirculations was enabled by optical microangiography protocol. From the imaging results, the spatial homogenization of capillary velocity (decreased CTH) was observed in the region of interest (ROI) corresponding to the stimulation, along with an increase in the MTT in the ROI to maintain sufficient oxygen exchange within the brain tissue during functional activation. We validated the oxygen consumption due to an increase of the MTT through demonstrating an increase in the deoxygenated hemoglobin (HbR) during the stimulation by the use of laser speckle contrast imaging.
NASA Astrophysics Data System (ADS)
Amirkhanian, Varoujan; Tsai, Shou-Kuan
2014-03-01
We introduce a novel and cost-effective capillary gel electrophoresis (CGE) system utilizing disposable pen-shaped gelcartridges for highly efficient, high speed, high throughput fluorescence detection of bio-molecules. The CGE system has been integrated with dual excitation and emission optical-fibers with micro-ball end design for fluorescence detection of bio-molecules separated and detected in a disposable pen-shaped capillary gel electrophoresis cartridge. The high-performance capillary gel electrophoresis (CGE) analyzer has been optimized for glycoprotein analysis type applications. Using commercially available labeling agent such as ANTS (8-aminonapthalene-1,3,6- trisulfonate) as an indicator, the capillary gel electrophoresis-based glycan analyzer provides high detection sensitivity and high resolving power in 2-5 minutes of separations. The system can hold total of 96 samples, which can be automatically analyzed within 4-5 hours. This affordable fiber optic based fluorescence detection system provides fast run times (4 minutes vs. 20 minutes with other CE systems), provides improved peak resolution, good linear dynamic range and reproducible migration times, that can be used in laboratories for high speed glycan (N-glycan) profiling applications. The CGE-based glycan analyzer will significantly increase the pace at which glycoprotein research is performed in the labs, saving hours of preparation time and assuring accurate, consistent and economical results.
An in vitro study of magnetic particle targeting in small blood vessels
NASA Astrophysics Data System (ADS)
Udrea, Laura Elena; Strachan, Norval J. C.; Bădescu, Vasile; Rotariu, Ovidiu
2006-10-01
The magnetic guidance and capture of particles inside the human body, via the circulatory system, is a novel method for the targeted delivery of drugs. This experimental study confirms in vitro that a dipolar capturing device, based on high-energy magnets with an active space of 8.7 cm × 10 cm × 10 cm, retains colloidal magnetic particles (MPs) (<30 nm) injected in the capillary tubes, where flow velocities are comparable to that encountered in the capillary beds of tumours (<0.5 cm s-1). The build-up of the deposition of the MPs was investigated using video imaging techniques that enabled continuous monitoring of the blocking of the vessel whilst simultaneously recording the colloid's flow rate. The parameters of practical importance (length of MP deposit, time of capillary blocking) were estimated and were found to be dependent on the initial fluid velocity, the MP concentration and the distance between the capillary tube and the polar magnetic pieces. Although the tube used in this experiment is larger (diameter = 0.75 mm, length = 100 mm) than that of real capillaries (diameter = 0.01 mm, length ~1.5 mm), the flow velocities chosen were similar to those encountered in the capillary beds of tumours and the length/diameter ratio was approximately equal (133 for the present set-up, 100-150 for real capillaries). In these circumstances and using the same magnetic field conditions (intensity, gradient) and MPs, there is close similarity with magnetic capture in a microscopic capillary system. Moreover, the macroscopic system permits analysis of the distribution of MPs in the active magnetic space, and consequently the maximum targetable volume. This study revealed that the capture of particles within the active space was strongly influenced by the gradient of the magnetic field and the flow velocity. Thus, when the magnetic field gradient had medium values (0.1-0.3 T cm-1) and the fluid velocity was small (0.15 cm s-1), the particles were captured in small, compact and stable deposits (L < 4 cm) and the time necessary for blocking of the capillary was <150 s. Doubling the value for the flow velocity did not influence significantly either the length of MP deposits nor the blocking time. However, lower gradients (<0.1 T cm-1) and larger velocities (0.3-0.9 cm s-1) result in the formation of larger deposits (4 cm < L < 10 cm) that are unstable at the beginning of the capture process. These large deposits do become stable given sufficient time for the deposition process to take place in conjunction with a decrease in the flow rate. As a consequence, the time necessary for blocking of the capillary increased up to 450 s. Decreasing the MP concentration from 0.02 g cm-3 to 0.005 g cm-3 decreased the deposit lengths by approximately 20% and doubled the values of the blocking time. The maximum targetable volume obtained by the present method is ~350 cm3, which corresponds to medium-sized tumours. The capillary vessels were blocked only for the situation that occurs for microcirculation within a tumour. This reduces the concentration of MPs trapped within the normal tissues, which occurs when using particles of micrometre size. This work showed the potential of using colloidal MPs and dipolar magnetic devices for treatment of human patients, when the affected sites are positioned at medium distances from the surface of the body (e.g. head, neck, breast, hands and legs).
Barakat, Fareed H; Luthra, Rajyalakshmi; Yin, C Cameron; Barkoh, Bedia A; Hai, Seema; Jamil, Waqar; Bhakta, Yaminiben I; Chen, Su; Medeiros, L Jeffrey; Zuo, Zhuang
2011-08-01
Nucleophosmin 1 (NPM1) is the most commonly mutated gene in acute myeloid leukemia. Detection of NPM1 mutations is useful for stratifying patients for therapy, predicting prognosis, and assessing for minimal residual disease. Several methods have been developed to rapidly detect NPM1 mutations in genomic DNA and/or messenger RNA specimens. To directly compare a quantitative real-time polymerase chain reaction (qPCR) assay with a widely used capillary electrophoresis assay for detecting NPM1 mutations. We adopted and modified a qPCR assay designed to detect the 6 most common NPM1 mutations and performed the assay in parallel with capillary electrophoresis assay in 207 bone marrow aspirate or peripheral blood samples from patients with a range of hematolymphoid neoplasms. The qPCR assay demonstrated a higher analytical sensitivity than the capillary electrophoresis 1/1000 versus 1/40, respectively. The capillary electrophoresis assay generated 10 equivocal results that needed to be repeated, whereas the qPCR assay generated only 1 equivocal result. After test conditions were optimized, the qPCR and capillary electrophoresis methods produced 100% concordant results, 85 positive and 122 negative. Given the higher analytical sensitivity and specificity of the qPCR assay, that assay is less likely to generate equivocal results than the capillary electrophoresis assay. Moreover, the qPCR assay is quantitative, faster, cheaper, less prone to contamination, and well suited for monitoring minimal residual disease.
Singer, Alexander; Duarte Fernandez, Roberto
2015-10-28
The Electronic Medical Record (EMR) is becoming increasingly common in health care settings. Research shows that EMRs have the potential to reduce instances of medication errors and improve communication between pharmacists and prescribers; however, more research is required to demonstrate whether this is true. This study aims to determine the effect of a newly implemented EMR system on communication between pharmacists and primary care clinicians. A retrospective chart analysis of primary care EMR data comparing faxed pharmacy communications captured before and after the implementation of an EMR system at an academic family medicine clinic. Communication requests were classified into the following various categories: refill accepted, refill denied, clarification, incorrect dose, interaction, drug insurance/coverage application, new prescription request, supplies request, continued care information, duplicate fax substitution, opioid early release request, confirmation by phone call, and other. The number and percentage of clarification requests, interaction notifications, and incorrect dose notifications were lower after the implementation of the EMR system. The number and percentage of refills accepted and new prescription requests increased after the implementation of the EMR system. The implementation of an EMR in an academic family medicine clinic had a significant effect on the volume of communication between pharmacists and prescribers. The amount of clarification requests and incorrect dosing communications decreased after EMR implementation. This suggests that EMRs improve prescribing safety. The increased amount of refills accepted and new prescription requests post EMR implementation suggests that the EMR is capable of changing prescription patterns.
Chemical evaluation of electronic cigarettes.
Cheng, Tianrong
2014-05-01
To review the available evidence evaluating the chemicals in refill solutions, cartridges, aerosols and environmental emissions of electronic cigarettes (e-cigarettes). Systematic literature searches were conducted to identify research related to e-cigarettes and chemistry using 5 reference databases and 11 search terms. The search date range was January 2007 to September 2013. The search yielded 36 articles, of which 29 were deemed relevant for analysis. The levels of nicotine, tobacco-specific nitrosamines (TSNAs), aldehydes, metals, volatile organic compounds (VOCs), flavours, solvent carriers and tobacco alkaloids in e-cigarette refill solutions, cartridges, aerosols and environmental emissions vary considerably. The delivery of nicotine and the release of TSNAs, aldehydes and metals are not consistent across products. Furthermore, the nicotine level listed on the labels of e-cigarette cartridges and refill solutions is often significantly different from measured values. Phenolic compounds, polycyclic aromatic hydrocarbons and drugs have also been reported in e-cigarette refill solutions, cartridges and aerosols. Varying results in particle size distributions of particular matter emissions from e-cigarettes across studies have been observed. Methods applied for the generation and chemical analyses of aerosols differ across studies. Performance characteristics of e-cigarette devices also vary across and within brands. Additional studies based on knowledge of e-cigarette user behaviours and scientifically validated aerosol generation and chemical analysis methods would be helpful in generating reliable measures of chemical quantities. This would allow comparisons of e-cigarette aerosol and traditional smoke constituent levels and would inform an evaluation of the toxicity potential of e-cigarettes.
Secchi, Francesca; Zwieniecki, Maciej A.
2012-01-01
It is assumed that the refilling of drought-induced embolism requires the creation of an osmotic gradient between xylem parenchyma cells and vessel lumens to generate the water efflux needed to fill the void. To assess the mechanism of embolism repair, it is crucial to determine if plants can up-regulate the efflux of osmotically active substances into embolized vessels and identify the major components of the released osmoticum. Here, we introduce a new approach of sap collection designed to separate water from nonembolized (functional) and embolized (nonfunctional) vessels. This new approach made possible the chemical analysis of liquid collected from both types of vessels in plants subjected to different levels of water stress. The technique also allowed us to determine the water volumes in nonfunctional vessels as a function of stress level. Overall, with the increase of water stress in plants, the osmotic potential of liquid collected from nonfunctional vessels increased while its volume decreased. These results revealed the presence of both sugars and ions in nonfunctional vessels at elevated levels in comparison with liquid collected from functional vessels, in which only traces of sugars were found. The increased sugar concentration was accompanied by decreased xylem sap pH. These results provide new insight into the biology of refilling, underlining the role of sugar and sugar transporters, and imply that a large degree of hydraulic compartmentalization must exist in the xylem during the refilling process. PMID:22837359
Influence of the capillary on the ignition of the transient spark discharge
NASA Astrophysics Data System (ADS)
Gerling, T.; Hoder, T.; Brandenburg, R.; Bussiahn, R.; Weltmann, K.-D.
2013-04-01
A self-pulsing negative dc discharge in argon generated in a needle-to-plane geometry at open atmosphere is investigated. Additionally, the needle electrode can be surrounded by a quartz capillary. It is shown that the relative position of the capillary end to the needle tip strongly influences the discharge inception and its spatio-temporal dynamics. Without the capillary for the selected working parameters a streamer corona is ignited, but when the capillary surrounds the needle, the transient spark (TS) discharge is ignited after a pre-streamer (PS) occurs. The time between PS and TS discharge depends on the relative capillary end position. The existence of the PS is confirmed by electro-optical characterization. Furthermore, spectrally and spatio-temporally resolved cross-correlation spectroscopy is applied to show the most active region of pre-phase emission activity as indicators for high local electric field strength. The results indicate that with a capillary in place, the necessary energy input of the pre-phase into the system is mainly reduced by additional electrical fields at the capillary edge. Even such a small change as a shift of dielectric surface close to the plasma largely changes the energy balance in the system.
Ostman, Pekka; Jäntti, Sirkku; Grigoras, Kestas; Saarela, Ville; Ketola, Raimo A; Franssila, Sami; Kotiaho, Tapio; Kostiainen, Risto
2006-07-01
A miniaturized nebulizer chip for capillary liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (capillary LC-microchip APCI-MS) is presented. The APCI chip consists of two wafers, a silicon wafer and a Pyrex glass wafer. The silicon wafer has a DRIE etched through-wafer nebulizer gas inlet, an edge capillary insertion channel, a stopper, a vaporizer channel and a nozzle. The platinum heater electrode and pads for electrical connection were patterned on to the Pyrex glass wafer. The two wafers were joined by anodic bonding, creating a microchip version of an APCI-source. The sample inlet capillary from an LC column is directly connected to the vaporizer channel of the APCI chip. The etched nozzle in the microchip forms a narrow sample plume, which is ionized by an external corona needle, and the formed ions are analyzed by a mass spectrometer. The nebulizer chip enables for the first time the use of low flow rate separation techniques with APCI-MS. The performance of capillary LC-microchip APCI-MS was tested with selected neurosteroids. The capillary LC-microchip APCI-MS provides quantitative repeatability and good linearity. The limits of detection (LOD) with a signal-to-noise ratio (S/N) of 3 in MS/MS mode for the selected neurosteroids were 20-1000 fmol (10-500 nmol l(-1)). LODs (S/N = 3) with commercial macro APCI with the same compounds using the same MS were about 10 times higher. Fast heat transfer allows the use of the optimized temperature for each compound during an LC run. The microchip APCI-source provides a convenient and easy method to combine capillary LC to any API-MS equipped with an APCI source. The advantages and potentials of the microchip APCI also make it a very attractive interface in microfluidic APCI-MS.
Sarcoplasmic reticulum buffering of myoplasmic calcium in bovine coronary artery smooth muscle.
Sturek, M; Kunda, K; Hu, Q
1992-01-01
1. We tested the hypothesis that the sarcoplasmic reticulum (SR) buffers (attenuates) the increase in averaged myoplasmic free [Ca2+] (Ca(im)) resulting from Ca2+ influx. 2. Fura-2 measurements of Ca(im) were obtained in single smooth muscle cells freshly dispersed from bovine coronary artery. 3. Caffeine (5 x 10(-3) M) elicited a transient increase in Ca(im) and depleted the SR Ca2+ store. In the continued presence of caffeine or 10(-5) M-ryanodine SR buffering of Ca(im) was inhibited. Subsequent exposure to high extracellular [K+] (greater than 30 mM, equimolar Na+ removal) elicited a 2-fold more rapid and 2-fold greater peak increase in Ca(im) than high K+ elicited when SR buffering of Ca(im) was normal. The augmented increase in Ca(im) was inhibited 35% by 10(-5) M-diltiazem, 65% by 2 x 10(-4) M-LaCl3, and 87% in Ca(2+)-free external solution. 4. When Ca(im) buffering capacity was increased by partially depleting the SR with a transient (1 min) exposure to caffeine, subsequent exposure to 80 nM-K+ solution increased Ca(im) almost 2-fold more slowly than 80 mM-K+ before depletion of Ca2+ from the SR. However, the influxing Ca2+ was sequestered by the SR and refilled it, as evident by the subsequent caffeine-induced Ca(im) transient being identical to the first. Increasing extracellular [K+] (thus, increasing depolarization and Na+ removal) caused proportional increases in Ca(im) and the subsequent caffeine-induced Ca(im) transients were proportionally larger, indicating a graded filling of the SR by Ca2+ influx. 5. Diltiazem (10(-5) M) inhibited the refilling of the SR achieved by 80 mM-K+, by 26%. Refilling was inhibited 76% by 80 mM-K+, Ca(2+)-free solution, indicating the fraction of refilling dependent on influx of Ca2+ through voltage-gated Ca2+ channels, leak channels, and other influx pathways. Mild depolarization with 35 mM-K+ (no Na+ removal) often caused no increase in Ca(im), but influx through voltage-gated Ca2+ channels occurred because the SR Ca2+ store was refilled. Also, 10(-5) M-diltiazem or 10(-6) M-TA3090 inhibited the refilling to levels attributable only to leak influx of Ca2+. 6. All data support our hypothesis that the SR significantly attenuates the amount of Ca2+ influx that accumulates to increase Ca(im).(ABSTRACT TRUNCATED AT 400 WORDS) PMID:1403813
Identification of Microorganisms by Modern Analytical Techniques.
Buszewski, Bogusław; Rogowska, Agnieszka; Pomastowski, Paweł; Złoch, Michał; Railean-Plugaru, Viorica
2017-11-01
Rapid detection and identification of microorganisms is a challenging and important aspect in a wide range of fields, from medical to industrial, affecting human lives. Unfortunately, classical methods of microorganism identification are based on time-consuming and labor-intensive approaches. Screening techniques require the rapid and cheap grouping of bacterial isolates; however, modern bioanalytics demand comprehensive bacterial studies at a molecular level. Modern approaches for the rapid identification of bacteria use molecular techniques, such as 16S ribosomal RNA gene sequencing based on polymerase chain reaction or electromigration, especially capillary zone electrophoresis and capillary isoelectric focusing. However, there are still several challenges with the analysis of microbial complexes using electromigration technology, such as uncontrolled aggregation and/or adhesion to the capillary surface. Thus, an approach using capillary electrophoresis of microbial aggregates with UV and matrix-assisted laser desorption ionization time-of-flight MS detection is presented.
Tavlarides, L.L.; Bae, J.H.
1991-12-24
A laser capillary spectrophotometric technique measures real time or near real time bivariate drop size and concentration distribution for a reactive liquid-liquid dispersion system. The dispersion is drawn into a precision-bore glass capillary and an appropriate light source is used to distinguish the aqueous phase from slugs of the organic phase at two points along the capillary whose separation is precisely known. The suction velocity is measured, as is the length of each slug from which the drop free diameter is calculated. For each drop, the absorptivity at a given wavelength is related to the molar concentration of a solute of interest, and the concentration of given drops of the organic phase is derived from pulse heights of the detected light. This technique permits on-line monitoring and control of liquid-liquid dispersion processes. 17 figures.
Weight-controlled capillary viscometer
NASA Astrophysics Data System (ADS)
Digilov, Rafael M.; Reiner, M.
2005-11-01
The draining of a water column through a vertical discharge capillary tube is examined with the aid of a force sensor. The change of the mass of the liquid in the column with time is found to be not purely exponential as implied by Poiseuille's law. Using observed residuals associated with a kinetic energy correction, an approximate formula for the mass as a function of time is derived and excellent agreement with experimental data is attained. These results are verified by a viscosity test of distilled water at room temperature. A simple and inexpensive weight-controlled capillary viscometer is proposed that is especially suitable for undergraduate physics and chemistry laboratories.
Structure of Particle Networks in Capillary Suspensions with Wetting and Nonwetting Fluids
2016-01-01
The mechanical properties of a suspension can be dramatically altered by adding a small amount of a secondary fluid that is immiscible with the bulk phase. The substantial changes in the strength of these capillary suspensions arise due to the capillary force inducing a percolating particle network. Spatial information on the structure of the particle networks is obtained using confocal microscopy. It is possible, for the first time, to visualize the different types of percolating structures of capillary suspensions in situ. These capillary networks are unique from other types of particulate networks due to the nature of the capillary attraction. We investigate the influence of the three-phase contact angle on the structure of an oil-based capillary suspension with silica microspheres. Contact angles smaller than 90° lead to pendular networks of particles connected with single capillary bridges or clusters comparable to the funicular state in wet granular matter, whereas a different clustered structure, the capillary state, forms for angles larger than 90°. Particle pair distribution functions are obtained by image analysis, which demonstrate differences in the network microstructures. When porous particles are used, the pendular conformation also appears for apparent contact angles larger than 90°. The complex shear modulus can be correlated to these microstructural changes. When the percolating structure is formed, the complex shear modulus increases by nearly three decades. Pendular bridges lead to stronger networks than the capillary state network conformations, but the capillary state clusters are nevertheless much stronger than pure suspensions without the added liquid. PMID:26807651
2013-01-01
Background Adults with severe malaria frequently require intravenous fluid therapy to restore their circulating volume. However, fluid must be delivered judiciously as both under- and over-hydration increase the risk of complications and, potentially, death. As most patients will be cared for in a resource-poor setting, management guidelines necessarily recommend that physical examination should guide fluid resuscitation. However, the reliability of this strategy is uncertain. Methods To determine the ability of physical examination to identify hypovolaemia, volume responsiveness, and pulmonary oedema, clinical signs and invasive measures of volume status were collected independently during an observational study of 28 adults with severe malaria. Results The physical examination defined volume status poorly. Jugular venous pressure (JVP) did not correlate with intravascular volume as determined by global end diastolic volume index (GEDVI; rs = 0.07, p = 0.19), neither did dry mucous membranes (p = 0.85), or dry axillae (p = 0.09). GEDVI was actually higher in patients with decreased tissue turgor (p < 0.001). Poor capillary return correlated with GEDVI, but was present infrequently (7% of observations) and, therefore, insensitive. Mean arterial pressure (MAP) correlated with GEDVI (rs = 0.16, p = 0.002), but even before resuscitation patients with a low GEDVI had a preserved MAP. Anuria on admission was unrelated to GEDVI and although liberal fluid resuscitation led to a median hourly urine output of 100 ml in 19 patients who were not anuric on admission, four (21%) developed clinical pulmonary oedema subsequently. MAP was unrelated to volume responsiveness (p = 0.71), while a low JVP, dry mucous membranes, dry axillae, increased tissue turgor, prolonged capillary refill, and tachycardia all had a positive predictive value for volume responsiveness of ≤50%. Extravascular lung water ≥11 ml/kg indicating pulmonary oedema was present on 99 of the 353 times that it was assessed during the study, but was identified on less than half these occasions by tachypnoea, chest auscultation, or an elevated JVP. A clear chest on auscultation and a respiratory rate <30 breaths/minute could exclude pulmonary oedema on 82% and 72% of occasions respectively. Conclusions Findings on physical examination correlate poorly with true volume status in adults with severe malaria and must be used with caution to guide fluid therapy. Trial registration Clinicaltrials.gov identifier: NCT00692627 PMID:24079262
Lynen, Frederic; Saavedra, Luis; Saveedra, Luis; Nickerson, Beverly; Sandra, Pat
2011-05-15
A multiplexed capillary electrophoresis (CE) system equipped with 96 channels was evaluated for high-throughput screening in drug discovery by microemulsion electrokinetic chromatography (MEEKC). Method transfer from a single channel to a multichannel CE system is described. Loss of efficiency and reduced migration times could be elucidated to the poor efficacy in Joule heat dissipation by forced air cooling in the multiarray system compared to liquid cooling in the single channel instrument. On the other hand, only 48 channels could actually be used because of the maximum total current of 3 mA. Precision data remained below 8% and 9% for migration times and peak areas, respectively. Some UV-detector cross-talk interference between neighboring capillary channels was noted. Impurities at 0.5% compared to the main peak (100%) could be detected with the multiplexed system which is 10 times lower compared to the single capillary system. Higher efficiency and improved figures of merit (absolute sensitivity and no cross-talk interferences) were obtained by using an array of only 24 capillaries. Copyright © 2011 Elsevier B.V. All rights reserved.
Horie, Kanta; Ikegami, Tohru; Hosoya, Ken; Saad, Nabil; Fiehn, Oliver; Tanaka, Nobuo
2007-09-14
Monolithic silica capillary columns for hydrophilic interaction liquid chromatography (HILIC) were prepared by on-column polymerization of acrylic acid on monolithic silica in a fused silica capillary modified with anchor groups. The products maintained the high permeability (K=5 x 10(-14)m(2)) and provided a plate height (H) of less than 10 microm at optimum linear velocity (u) and H below 20 microm at u=6mm/s for polar solutes including nucleosides and carbohydrates. The HILIC mode monolithic silica capillary column was able to produce 10000 theoretical plates (N) with column dead time (t(0)) of 20s at a pressure drop of 20 MPa or lower. The total performance was much higher than conventional particle-packed HILIC columns currently available. The gradient separations of peptides by a capillary LC-electrospray mass spectrometry system resulted in very different retention selectivity between reversed-phase mode separations and the HILIC mode separations with a peak capacity of ca. 100 in a 10 min gradient time in either mode. The high performance observed with the monolithic silica capillary column modified with poly(acrylic acid) suggests that the HILIC mode can be an alternative to the reversed-phase mode for a wide range of compounds, especially for those of high polarity in isocratic as well as gradient elution.
Evaporation effect on two-dimensional wicking in porous media.
Benner, Eric M; Petsev, Dimiter N
2018-03-15
We analyze the effect of evaporation on expanding capillary flow for losses normal to the plane of a two-dimensional porous medium using the potential flow theory formulation of the Lucas-Washburn method. Evaporation induces a finite steady state liquid flux on capillary flows into fan-shaped domains which is significantly greater than the flux into media of constant cross section. We introduce the evaporation-capillary number, a new dimensionless quantity, which governs the frontal motion when multiplied by the scaled time. This governing product divides the wicking behavior into simple regimes of capillary dominated flow and evaporative steady state, as well as the intermediate regime of evaporation influenced capillary driven motion. We also show flow dimensionality and evaporation reduce the propagation rate of the wet front relative to the Lucas-Washburn law. Copyright © 2017 Elsevier Inc. All rights reserved.
de Miguel, Dunia; Burgaleta, Carmen; Reyes, Eduardo; Pascual, Teresa
2003-07-01
We evaluated a new portable monitor (AvoSure PT PRO, Menarini Diagnostics, Firenze, Italy) developed to test the prothrombin time in capillary blood and plasma by comparing it with the standard laboratory determination. We studied 62 patients receiving acenocoumarol therapy. The international normalized ratio (INR) in capillary blood was analyzed by 2 methods: AvoSure PT PRO and Thrombotrack Nycomed Analyzer (Axis-Shield, Dundee, Scotland). Parallel studies were performed in plasma samples by a reference method using the Behring Coagulation Timer (Behring Diagnostics, Marburg, Germany). Plasma samples also were tested with the AvoSure PT PRO. Correlation was good for INR values for capillary blood and plasma samples by AvoSure PT PRO and our reference method (R2 = 0.8596) and for capillary blood samples tested by the AvoSure PT PRO and Thrombotrack Nycomed Analyzer (R2 = 0.8875). The correlation for INR in capillary blood and plasma samples by AvoSure PT PRO was 0.6939 (P < .0004). Capillary blood determinations are rapid and effective for monitoring oral anticoagulation therapy and have a high correlation to plasma determinations. AvoSure PT PRO is accurate for controlling INR in plasma and capillary blood samples, may be used in outpatient clinics, and has advantages over previous portable monitors.
Variations in magma supply rate at Kilauea Volcano, Hawaii
Dvorak, John J.; Dzurisin, Daniel
1993-01-01
When an eruption of Kilauea lasts more than 4 months, so that a well-defined conduit has time to develop, magma moves freely through the volcano from a deep source to the eruptive site at a constant rate of 0.09 km3/yr. At other times, the magma supply rate to Kilauea, estimated from geodetic measurements of surface displacements, may be different. For example, after a large withdrawal of magma from the summit reservoir, such as during a rift zone eruption, the magma supply rate is high initially but then lessens and exponentially decays as the reservoir refills. Different episodes of refilling may have different average rates of magma supply. During four year-long episodes in the 1960s, the annual rate of refilling varied from 0.02 to 0.18 km3/yr, bracketing the sustained eruptive rate of 0.09 km3/yr. For decade-long or longer periods, our estimate of magma supply rate is based on long-term changes in eruptive rate. We use eruptive rate because after a few dozen eruptions the volume of magma that passes through the summit reservoir is much larger than the net change of volume of magma stored within Kilauea. The low eruptive rate of 0.009 km3/yr between 1840 and 1950, compared to an average eruptive rate of 0.05 km3/yr since 1950, suggests that the magma supply rate was lower between 1840 and 1950 than it has been since 1950. An obvious difference in activity before and since 1950 was the frequency of rift zone eruptions: eight rift zone eruptions occurred between 1840 and 1950, but more than 20 rift zone eruptions have occurred since 1950. The frequency of rift zone eruptions influences magma supply rate by suddenly lowering pressure of the summit magma reservoir, which feeds magma to rift zone eruptions. A temporary drop of reservoir pressure means a larger-than-normal pressure difference between the reservoir and a deeper source, so magma is forced to move upward into Kilauea at a faster rate.
Tsg101 regulates PI(4,5)P2/Ca2+ signaling for HIV-1 Gag assembly
Ehrlich, Lorna S.; Medina, Gisselle N.; Photiadis, Sara; Whittredge, Paul B.; Watanabe, Susan; Taraska, Justin W.; Carter, Carol A.
2014-01-01
Our previous studies identified the 1,4,5-inositol trisphosphate receptor (IP3R), a channel mediating release of Ca2+ from ER stores, as a cellular factor differentially associated with HIV-1 Gag that might facilitate ESCRT function in virus budding. Channel opening requires activation that is initiated by binding of 1,4,5-triphosphate (IP3), a product of phospholipase C (PLC)-mediated PI(4,5)P2 hydrolysis. The store emptying that follows stimulates store refilling which requires intact PI(4,5)P2. Raising cytosolic Ca2+ promotes viral particle production and our studies indicate that IP3R and the ER Ca2+ store are the physiological providers of Ca2+ for Gag assembly and release. Here, we show that Gag modulates ER store gating and refilling. Cells expressing Gag exhibited a higher cytosolic Ca2+ level originating from the ER store than control cells, suggesting that Gag induced release of store Ca2+. This property required the PTAP motif in Gag that recruits Tsg101, an ESCRT-1 component. Consistent with cytosolic Ca2+ elevation, Gag accumulation at the plasma membrane was found to require continuous IP3R activation. Like other IP3R channel modulators, Gag was detected in physical proximity to the ER and to endogenous IP3R, as indicated respectively by total internal reflection fluorescence (TIRF) and immunoelectron microscopy (IEM) or indirect immunofluorescence. Reciprocal co-immunoprecipitation suggested that Gag and IP3R proximity is favored when the PTAP motif in Gag is intact. Gag expression was also accompanied by increased PI(4,5)P2 accumulation at the plasma membrane, a condition favoring store refilling capacity. Supporting this notion, Gag particle production was impervious to treatment with 2-aminoethoxydiphenyl borate, an inhibitor of a refilling coupling interaction. In contrast, particle production by a Gag mutant lacking the PTAP motif was reduced. We conclude that a functional PTAP L domain, and by inference Tsg101 binding, confers Gag with an ability to modulate both ER store Ca2+ release and ER store refilling. PMID:24904548
Influence of mixing conditions on the rheological properties and structure of capillary suspensions
Bossler, Frank; Weyrauch, Lydia; Schmidt, Robert; Koos, Erin
2017-01-01
The rheological properties of a suspension can be dramatically altered by adding a small amount of a secondary fluid that is immiscible with the bulk liquid. These capillary suspensions exist either in the pendular state where the secondary fluid preferentially wets the particles or the capillary state where the bulk fluid is preferentially wetting. The yield stress, as well as storage and loss moduli, depends on the size and distribution of secondary phase droplets created during sample preparation. Enhanced droplet breakup leads to stronger sample structures. In capillary state systems, this can be achieved by increasing the mixing speed and time of turbulent mixing using a dissolver stirrer. In the pendular state, increased mixing speed also leads to better droplet breakup, but spherical agglomeration is favored at longer times decreasing the yield stress. Additional mixing with a ball mill is shown to be beneficial to sample strength. The influence of viscosity variance between the bulk and second fluid on the droplet breakup is excluded by performing experiments with viscosity-matched fluids. These experiments show that the capillary state competes with the formation of Pickering emulsion droplets and is often more difficult to achieve than the pendular state. PMID:28194044
2016-01-01
We developed a technique to monitor spatially confined surface reactions with mass spectrometry under ambient conditions, without the need for voltage or organic solvents. Fused-silica capillaries immersed in an aqueous solution, positioned in close proximity to each other and the functionalized surface, created a laminar flow junction with a resulting reaction volume of ∼5 pL. The setup was operated with a syringe pump, delivering reagents to the surface through a fused-silica capillary. The other fused-silica capillary was connected to a Venturi easy ambient sonic-spray ionization source, sampling the resulting analytes at a slightly higher flow rate compared to the feeding capillary. The combined effects of the inflow and outflow maintains a chemical microenvironment, where the rate of advective transport overcomes diffusion. We show proof-of-concept where acetylcholinesterase was immobilized on an organosiloxane polymer through electrostatic interactions. The hydrolysis of acetylcholine by acetylcholinesterase into choline was monitored in real-time for a range of acetylcholine concentrations, fused-silica capillary geometries, and operating flow rates. Higher reaction rates and conversion yields were observed with increasing acetylcholine concentrations, as would be expected. PMID:27249533
Yüksel, Sezin; Schwenke, Almut M; Soliveri, Guido; Ardizzone, Silvia; Weber, Karina; Cialla-May, Dana; Hoeppener, Stephanie; Schubert, Ulrich S; Popp, Jürgen
2016-10-05
In the present study, an ultra-sensitive and highly reproducible novel SERS-based capillary platform was developed and utilized for the trace detection of tetrahydrocannabinol (THC). The approach combines the advantages of microwave-assisted nanoparticle synthesis, plasmonics and capillary forces. By employing a microwave-assisted preparation method, glass capillaries were reproducibly coated with silver nanoparticles in a batch fabrication process that required a processing time of 3 min without needing to use any pre-surface modifications or add surfactants. The coated capillaries exhibited an excellent SERS activity with a high reproducibility and enabled the detection of low concentrations of target molecules. At the same time, only a small amount of analyte and a short and simple incubation process was required. The developed platform was applied to the spectroscopic characterization of tetrahydrocannabinol (THC) and its identification at concentration levels down to 1 nM. Thus, a highly efficient detection system for practical applications, e.g., in drug monitoring/detection, is introduced, which can be fabricated at low cost by using microwave-assisted batch synthesis techniques. Copyright © 2016 Elsevier B.V. All rights reserved.
A comparison of capillary hydraulic conductivities in postural and locomotor muscle.
McDonagh, P F; Gore, R W
1982-09-01
In a comparative skeletal muscle study Folkow and Halicka (Microvasc. Res. 1: 1-14, 1968) reported that the capillary filtration coefficient (CFC) of postural (red) muscle was two times the CFC of locomotor (white) muscle. It was concluded that the twofold difference in CFC was due solely to a difference in the perfused capillary surface areas (Sf) of red vs. white muscle. However, CFC is the product of capillary hydraulic conductivity (LP) and Sf. Hence their conclusion assumed that the average LP of red muscle capillaries is exactly equal to the average LP of white muscle capillaries. The following study was undertaken to test the validity of this assumption. The microocclusion procedures and analytical model described by Lee et al. (Circ. Res. 28: 358-370, 1971) and Gore [Am. J. Physiol. 242 (Heart Circ. Physiol. 11): H268-H287, 1982] were used to determine LP. Independent measurements of LP were recorded from single capillaries in red, anterior latissimus dorsi (ALD) and white, posterior latissimus dorsi (PLD) muscles of chickens anesthetized with L.A. Thesia. We found that the mean capillary hydraulic conductivity in postural muscle [(LP)ALD = 0.20 +/- 0.06 (SE) micrometers . s-1 . cmH2O-1 (n = 11)] was significantly different from the mean capillary hydraulic conductivity in locomotor muscle [(LP)PLD = 0.061 +/- 0.01 micrometers . s-1 . cmH2O-1 (n = 14)] (P less than 0.05). These results provide direct evidence that observed differences in red vs. white muscle CFC's may not be due solely to different perfused capillary surface areas but may also be due to differences in capillary hydraulic conductivity.
Medication Days' Supply, Adherence, Wastage, and Cost Among Chronic Patients in Medicaid
Taitel, Michael; Fensterheim, Leonard; Kirkham, Heather; Sekula, Ryan; Duncan, Ian
2012-01-01
Background In an attempt to contain Medicaid pharmacy costs, nearly all states impose dispensing limits on medication days' supply. Although longer days' supply appears to increase the potential for medication wastage, previous studies suggest that it may also decrease pharmacy expenditures by reducing dispensing fees and drug ingredient costs. This study was conducted to determine whether 90-day refills at community pharmacies could improve adherence, minimize wastage, and control costs. Methods This retrospective observational study used California Medicaid claims, from the Walgreens pharmacy chain dated January 2010, to identify 52,898 patients prescribed statin, antihypertensive, selective serotonin reuptake inhibitor (SSRI), or oral hypoglycemic medications. Adherence was measured by medication possession ratio (MPR) and persistency with a 30-day gap. Medication wastage was defined as a switch of drug or drug strength within the same therapeutic class that occurred before the expected refill date. Results Adherence was 20% higher and persistency was 23% higher for the 90-day group than the 30-day group. This amounted to an average increase of 0.14 MPR and 44 days of continuous therapy. The two groups had comparable proportions of patients with wastage. After subtracting an average wastage cost of $7.34 per person per year (PPPY), all therapeutic classes had PPPY savings: statins ($7.70), antihypertensives ($10.80), SSRIs ($18.52), and oral hypoglycemics ($26.86). Conclusion Across four drug categories and compared to 30-day refills, patients with 90-day refills had greater medication adherence, greater persistency, nominal wastage, and greater savings. PMID:24800150
van den Boogaard, Jossy; Lyimo, Ramsey A; Boeree, Martin J; Kibiki, Gibson S; Aarnoutse, Rob E
2011-09-01
To assess adherence to community-based directly observed treatment (DOT) among Tanzanian tuberculosis patients using the Medication Event Monitoring System (MEMS) and to validate alternative adherence measures for resource-limited settings using MEMS as a gold standard. This was a longitudinal pilot study of 50 patients recruited consecutively from one rural hospital, one urban hospital and two urban health centres. Treatment adherence was monitored with MEMS and the validity of the following adherence measures was assessed: isoniazid urine test, urine colour test, Morisky scale, Brief Medication Questionnaire, adapted AIDS Clinical Trials Group (ACTG) adherence questionnaire, pill counts and medication refill visits. The mean adherence rate in the study population was 96.3% (standard deviation, SD: 7.7). Adherence was less than 100% in 70% of the patients, less than 95% in 21% of them, and less than 80% in 2%. The ACTG adherence questionnaire and urine colour test had the highest sensitivities but lowest specificities. The Morisky scale and refill visits had the highest specificities but lowest sensitivities. Pill counts and refill visits combined, used in routine practice, yielded moderate sensitivity and specificity, but sensitivity improved when the ACTG adherence questionnaire was added. Patients on community-based DOT showed good adherence in this study. The combination of pill counts, refill visits and the ACTG adherence questionnaire could be used to monitor adherence in settings where MEMS is not affordable. The findings with regard to adherence and to the validity of simple adherence measures should be confirmed in larger populations with wider variability in adherence rates.
Chemical evaluation of electronic cigarettes
Cheng, Tianrong
2014-01-01
Objective To review the available evidence evaluating the chemicals in refill solutions, cartridges, aerosols and environmental emissions of electronic cigarettes (e-cigarettes). Methods Systematic literature searches were conducted to identify research related to e-cigarettes and chemistry using 5 reference databases and 11 search terms. The search date range was January 2007 to September 2013. The search yielded 36 articles, of which 29 were deemed relevant for analysis. Results The levels of nicotine, tobacco-specific nitrosamines (TSNAs), aldehydes, metals, volatile organic compounds (VOCs), flavours, solvent carriers and tobacco alkaloids in e-cigarette refill solutions, cartridges, aerosols and environmental emissions vary considerably. The delivery of nicotine and the release of TSNAs, aldehydes and metals are not consistent across products. Furthermore, the nicotine level listed on the labels of e-cigarette cartridges and refill solutions is often significantly different from measured values. Phenolic compounds, polycyclic aromatic hydrocarbons and drugs have also been reported in e-cigarette refill solutions, cartridges and aerosols. Varying results in particle size distributions of particular matter emissions from e-cigarettes across studies have been observed. Methods applied for the generation and chemical analyses of aerosols differ across studies. Performance characteristics of e-cigarette devices also vary across and within brands. Conclusions Additional studies based on knowledge of e-cigarette user behaviours and scientifically validated aerosol generation and chemical analysis methods would be helpful in generating reliable measures of chemical quantities. This would allow comparisons of e-cigarette aerosol and traditional smoke constituent levels and would inform an evaluation of the toxicity potential of e-cigarettes. PMID:24732157
Regueiro, Jorge; Giri, Anupam; Wenzl, Thomas
2016-06-21
Fast market penetration of electronic cigarettes is leading to an exponentially growing number of electronic refill liquids with different nicotine contents and an endless list of flavors. Therefore, rapid and simple methods allowing a fast screening of these products are necessary to detect harmful substances which can negatively impact the health of consumers. In this regard, the present work explores the capabilities of differential ion mobility spectrometry coupled to tandem mass spectrometry for high-throughput analysis of nicotine and 11 related compounds in commercial refill liquids for electronic cigarettes. The influence of main factors affecting the ion mobility separation, such as modifier types and concentration, separation voltage, and temperature, was systematically investigated. Despite small molecular weight differences among the studied compounds, a good separation was achieved in the ion mobility cell under the optimized conditions, which involved the use of ethanol as a polar gas-phase chemical modifier. Indeed, differential ion mobility was able to resolve (resolution >4) nicotine from its structural isomer anabasine without the use of any chromatographic separation. The quantitative performance of the proposed method was then evaluated, showing satisfactory precision (RSD ≤ 16%) and recoveries ranging from 85 to 100% for nicotine, and from 84 to 126% for the rest of the target analytes. Several commercial electronic cigarette refill liquids were analyzed to demonstrate the applicability of the method. In some cases, significant differences were found between labeled and measured levels of nicotine. Anatabine, cotinine, myosmine, and nornicotine were also found in some of the analyzed samples.
Avong, Yohanna Kambai; Aliyu, Gambo Gumel; Jatau, Bolajoko; Gurumnaan, Ritmwa; Danat, Nanfwang; Kayode, Gbenga Ayodele; Adekanmbi, Victor; Dakum, Patrick
2018-01-01
The landscape of Human Immunodeficiency Virus (HIV) epidemic control is shifting with the United Nations Programme on HIV/AIDS (UNAIDS) 90-90-90 benchmarks for epidemic control. Community-based Antiretroviral Therapy (CART) models have improved treatment uptake and demonstrated good clinical outcomes. We assessed the feasibility of integrating community pharmacy as a task shift structure for differentiated community ART in Abuja-Nigeria. Stable patients on first line ART regimens from public health facilities were referred to community pharmacies in different locations within the Federal Capital Territory, Abuja for prescription refills and treatment maintenance. Bio-demographic and clinical data were collected from February 25, 2016 to May 31st, 2017 and descriptive statistics analysis applied. The outcomes of measure were prescription refill and patient retention in care at the community pharmacy. Almost 10% of stable patients on treatment were successfully devolved from eight health facilities to ten community pharmacies. Median age of the participants was 35 years [interquartile range (IQR); 30, 41] with married women in the majority. Prescription refill was 100% and almost all the participants (99.3%) were retained in care after they were devolved to the community pharmacies. Only one participant was lost-to-follow-up as a result of death. Excellent prescription refill and high retention in care with very low loss-to-follow-up were associated with the community pharmacy model. The use of community pharmacy for community ART is feasible in Nigeria. We recommend the scale up of the model in all the 36 states of Nigeria.
Two-stream modeling of plasmaspheric refilling
NASA Technical Reports Server (NTRS)
Guiter, S. M.; Gombosi, T. I.; Rasmussen, C. E.
1995-01-01
Plasmaspheric refilling on an L = 4 flux tube was studied by using a time-dependent, hydrodynamic plasmaspheric flow model in which the ion streams from the two hemispheres are treated as distinct fluids. In the model the continuity, momentum, and energy equations of a two-ion (O(+) and H(+)), quasi-neutral, currentless plasma are solved along a closed geomagnetic field line; diffusive equilibrium is not assumed. collisions between all stream pairs and with neutral species are included. The model includes a corotating, tilted dipole magnetic field and neutral winds. Ionospheric sources and sinks are accounted for in a self-consistent manner. Electrons are assumed to be heated by photoelectrons. The model flux tube extends from a 200-km altitude in one hemisphere to a 200-km altitude in the other hemisphere. Initially, the upwelling streams pass through each other practically unimpeded. When the streams approach the boundary in the conjugate ionosphere, a shock develops there, which moves upward and dissipates slowly; at about the same time a reverse shock develops in the hemisphere of origin, which moves upward. After about 1 hour, large shocks develop in each stream near the equator; these shocks move toward the equator and downward after crossing the equator. However, these shocks are probably artificial, because counterstreaming flows occur in each H(+) fluid, which the model can only handle by creating shocks.
Bio rapid prototyping by extruding/aspirating/refilling thermoreversible hydrogel.
Iwami, K; Noda, T; Ishida, K; Morishima, K; Nakamura, M; Umeda, N
2010-03-01
This paper reports a method for rapid prototyping of cell tissues, which is based on a system that extrudes, aspirates and refills a mixture of cells and thermoreversible hydrogel as a scaffold. In the extruding mode, a cell-mixed scaffold solution in the sol state is extruded from a cooled micronozzle into a temperature-controlled substrate, which keeps the scaffold in the gel state. In the aspiration mode, the opposite process is performed by Bernoulli suction. In the refilling mode, the solution is extruded into a groove created in the aspiration mode. The minimum width of extruded hydrogel pattern is 114 +/- 15 microm by employing a nozzle of diameter 100 microm, and that of aspirated groove was 355 +/- 10 microm using a 500 microm-diameter nozzle. Gum arabic is mixed with the scaffold solution to avoid peeling-off of the gel pattern from the substrate. Patterning of Sf-9 cell tissue is demonstrated, and the stability of the patterned cell is investigated. This system offers a procedure for rapid prototyping and local modification of cell scaffolds for tissue engineering.
Numerical investigation of performance of vane-type propellant management device by VOF methods
NASA Astrophysics Data System (ADS)
Liu, J. T.; Zhou, C.; Wu, Y. L.; Zhuang, B. T.; Li, Y.
2015-01-01
The orbital propellant management performance of the vane-type tank is so important for the propellant system and it determines the lifetime of the satellite. The propellant in the tank can be extruded by helium gas. To study the two phase distribution in the vane-type surface tension tank and the capability of the vane-type propellant management device (PMD), a large volume vane-type surface tension tank is analysed using 3-D unsteady numerical simulations. VOF methods are used to analyse the location of the interface of the two phase. Performances of the propellant acquisition vanes and propellant refillable reservoir in the tank are investigated. The flow conductivity of the propellant acquisition vanes and the liquid storage capacity of propellant refillable reservoir can be affected by the value of the gravity and the volume of the propellant in the tank. To avoid the large resistance causing by surface tension in an outflow of a small hole, the design of the vanes in a propellant refillable reservoir should have suitable space.
Enhanced laser radiation pressure acceleration of protons with a gold cone-capillary
NASA Astrophysics Data System (ADS)
Lv, Chong; Xie, Bai-Song; Wan, Feng; Hou, Ya-Juan; Jia, Mo-Ran; Sang, Hai-Bo; Hong, Xue-Ren; Liu, Shi-Bing
2017-03-01
A scheme with a gold cone-capillary is proposed to improve the protons acceleration, and involved problems are investigated by using the two-dimensional particle-in-cell simulations. It is demonstrated that the cone-capillary can efficiently guide and collimate the protons to a longer distance and result in a better beam quality with a dense density ≥ 10 n c , monoenergetic peak energy E k ˜ 1.51 GeV , spatial emittance ˜ 0.0088 mm mrad with divergence angle θ ˜ 1.0 ° and diameter ˜ 0.5 μ m . The enhancement is mainly attributed to the focusing effect by the transverse electric field generated by the cone as well as the capillary, which can prevent greatly the protons from expanding in the transverse direction. Comparable to without the capillary, the protons energy spectra have a stable monoenergetic peak and divergence angle nearby 1.0 ° in longer time. Besides, the efficiency of acceleration depending on the capillary length is explored, and the optimal capillary length is also achieved. Such a target may be beneficial to many applications such as ion fast ignition in inertial fusion, proton therapy and so on.
Factors affecting the separation performance of proteins in capillary electrophoresis.
Zhu, Yueping; Li, Zhenqing; Wang, Ping; Shen, Lisong; Zhang, Dawei; Yamaguchi, Yoshinori
2018-04-15
Capillary electrophoresis (CE) is an effective tool for protein separation and analysis. Compared with capillary gel electrophoresis (CGE), non-gel sieving capillary electrophoresis (NGSCE) processes the superiority on operation, repeatability and automaticity. Herein, we investigated the effect of polymer molecular weight and concentration, electric field strength, and the effective length of the capillary on the separation performance of proteins, and find that (1) polymer with high molecular weight and concentration favors the separation of proteins, although concentrated polymer hinders its injection into the channel of the capillary due to its high viscosity. (2) The resolution between the adjacent proteins decreases with the increase of electric field strength. (3) When the effective length of the capillary is long, the separation performance improves at the cost of separation time. (4) 1.4% (w/v) hydroxyethyl cellulose (HEC), 100 V/cm voltage and 12 cm effective length offers the best separation for the proteins with molecular weight from 14,400 Da to 97,400 Da. Finally, we employed the optimal electrophoretic conditions to resolve Lysozyme, Ovalbumin, BSA and their mixtures, and found that they were baseline resolved within 15 min. Copyright © 2018 Elsevier B.V. All rights reserved.
A two-step method for rapid characterization of electroosmotic flows in capillary electrophoresis.
Zhang, Wenjing; He, Muyi; Yuan, Tao; Xu, Wei
2017-12-01
The measurement of electroosmotic flow (EOF) is important in a capillary electrophoresis (CE) experiment in terms of performance optimization and stability improvement. Although several methods exist, there are demanding needs to accurately characterize ultra-low electroosmotic flow rates (EOF rates), such as in coated capillaries used in protein separations. In this work, a new method, called the two-step method, was developed to accurately and rapidly measure EOF rates in a capillary, especially for measuring the ultra-low EOF rates in coated capillaries. In this two-step method, the EOF rates were calculated by measuring the migration time difference of a neutral marker in two consecutive experiments, in which a pressure driven was introduced to accelerate the migration and the DC voltage was reversed to switch the EOF direction. Uncoated capillaries were first characterized by both this two-step method and a conventional method to confirm the validity of this new method. Then this new method was applied in the study of coated capillaries. Results show that this new method is not only fast in speed, but also better in accuracy. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Laser absorption waves in metallic capillaries
NASA Astrophysics Data System (ADS)
Anisimov, V. N.; Arutiunian, R. V.; Bol'Shov, L. A.; Kanevskii, M. F.; Kondrashov, V. V.
1987-07-01
The propagation of laser absorption waves in metallic capillaries was studied experimentally and numerically during pulsed exposure to CO2 laser radiation. The dependence of the plasma front propagation rate on the initial air pressure in the capillary is determined. In a broad range of parameters, the formation time of the optically opaque plasma layer is governed by the total laser pulse energy from the beginning of the exposure to the instant screening appears, and is weakly dependent on the pulse shape and gas pressure.
Use of Plastic Capillaries for Macromolecular Crystallization
NASA Technical Reports Server (NTRS)
Potter, Rachel R.; Hong, Young-Soo; Ciszak, Ewa M.
2003-01-01
Methods of crystallization of biomolecules in plastic capillaries (Nalgene 870 PFA tubing) are presented. These crystallization methods used batch, free-interface liquid- liquid diffusion alone, or a combination with vapor diffusion. Results demonstrated growth of crystals of test proteins such as thaumatin and glucose isomerase, as well as protein studied in our laboratory such dihydrolipoamide dehydrogenase. Once the solutions were loaded in capillaries, they were stored in the tubes in frozen state at cryogenic temperatures until the desired time of activation of crystallization experiments.
Szarka, Mate; Guttman, Andras
2017-10-17
We present the application of a smartphone anatomy based technology in the field of liquid phase bioseparations, particularly in capillary electrophoresis. A simple capillary electrophoresis system was built with LED induced fluorescence detection and a credit card sized minicomputer to prove the concept of real time fluorescent imaging (zone adjustable time-lapse fluorescence image processor) and separation controller. The system was evaluated by analyzing under- and overloaded aminopyrenetrisulfonate (APTS)-labeled oligosaccharide samples. The open source software based image processing tool allowed undistorted signal modulation (reprocessing) if the signal was inappropriate for the actual detection system settings (too low or too high). The novel smart detection tool for fluorescently labeled biomolecules greatly expands dynamic range and enables retrospective correction for injections with unsuitable signal levels without the necessity to repeat the analysis.
Muroi, Eiji; Hara, Toshihide; Yanaba, Koichi; Ogawa, Fumihide; Yoshizaki, Ayumi; Takenaka, Motoi; Shimizu, Kazuhiro; Sato, Shinichi
2011-12-01
Microvascular lesions are a predominant feature in systemic sclerosis (SSc) and seem to play a central pathogenic role. The presence of nailfold capillary abnormalities is useful in diagnosing SSc. Capillaroscopy, however, usually requires special equipment and may be time consuming. Dermatoscope has been presented as a new diagnostic tool for quick and efficient examination of nailfold capillaries for circumstances when standard microscope equipment is not available. To assess the practical utility of dermatoscope for assessment of capillary morphology in patients with SSc, 83 Japanese patients with SSc (68 women, 15 men) and 68 healthy controls were examined in the study. Twenty-one patients (16 women, 5 men) had diffuse cutaneous SSc and 62 (52 women, 10 men) had limited cutaneous SSc. Enlarged capillaries and hemorrhages were evaluated in all 10 fingers with either naked eyes or DermLite(®) DL100 dermatoscope. Enlarged capillaries and hemorrhages were significantly more frequently detected with dermatoscope than without it. These findings were observed most frequently in the fourth finger. The presence of two or more enlarged capillaries in one or more fingers showed 83.1% sensitivity and 100% specificity for SSc. Among patients with SSc with anti-topoisomerase I antibody, the disease duration correlated negatively with the dermatoscopic number of enlarged capillaries and hemorrhages. Dermatoscope allows the easy and rapid identification of capillary nailfold morphological changes in SSc and should be routinely used for diagnosing SSc.
S-Adenosylhomocysteine Assay in the Urine by Capillary Electrophoresis.
Luzyanin, B P; Ivanov, A V; Viryus, E D; Kubatiev, A A
2015-08-01
We present a simple and effective method for measuring urine S-adenosylhomocysteine by capillary electrophoresis without using modifiers. The detection threshold of the method is 0.1 μM S-adenosylhomocysteine, the time of analysis 13 min, reproducibility at physiological concentrations within 4%.
Acoustic cavitation of individual ultrasound contrast agent microbubbles confined in capillaries
NASA Astrophysics Data System (ADS)
Almaqwashi, Ali; McIntyre, David; Ammi, Azzdine
2011-10-01
Ultrasound targeted therapies mainly rely on the inertial cavitation of ultrasound contrast agent (UCA) microbubbles. Our objective is to determine the cavitation acoustic pressure threshold for the destruction of UCA microbubbles inside cellulose capillaries. Acoustic emission from individual Optison microbubbles confined inside a 200-μm diameter capillary was detected using a passive cavitation detection system. Excitation signals from a 2.25 MHz transmitter were applied to the microbubbles while their acoustic emission was detected by a broadband 15 MHz receiver. Time traces were recorded (100 MHz sampling, 12- bit), and frequency-domain analysis of the received signals was performed to characterize microbubble cavitation. The cavitation acoustic pressure threshold was found to be 1 MPa inside the capillary in comparison with ˜0.7 MPa previously reported for unconfined UCA microbubbles. This work provides a clearer understanding of the role of ultrasound contrast agent dynamics inside a capillary.
Capillary-induced crack healing between surfaces of nanoscale roughness.
Soylemez, Emrecan; de Boer, Maarten P
2014-10-07
Capillary forces are important in nature (granular materials, insect locomotion) and in technology (disk drives, adhesion). Although well studied in equilibrium state, the dynamics of capillary formation merit further investigation. Here, we show that microcantilever crack healing experiments are a viable experimental technique for investigating the influence of capillary nucleation on crack healing between rough surfaces. The average crack healing velocity, v̅, between clean hydrophilic polycrystalline silicon surfaces of nanoscale roughness is measured. A plot of v̅ versus energy release rate, G, reveals log-linear behavior, while the slope |d[log(v̅)]/dG| decreases with increasing relative humidity. A simplified interface model that accounts for the nucleation time of water bridges by an activated process is developed to gain insight into the crack healing trends. This methodology enables us to gain insight into capillary bridge dynamics, with a goal of attaining a predictive capability for this important microelectromechanical systems (MEMS) reliability failure mechanism.
Du, Haiqin; Zhang, Chong; Mao, Ke; Wang, Yanmei
2017-08-01
In this work, an antifouling capillary modified with star-shaped poly(2-methyl-2-oxazoline)-based copolymer was used to study the interaction between acetaminophen (APAP) and bovine serum albumin (BSA) by frontal analysis capillary electrophoresis (FACE). The star-shaped copolymer, poly(ethylene imine)-graft-poly(2-methyl-2-oxazoline) (PEI-g-PMOXA), was immobilized onto the fused-silica capillary inner wall via dopamine-assisted co-deposition strategy, yielding a PEI-g-PMOXA/polydopamine (PDA)-coated antifouling capillary, i.e., an antifouling capillary coated with the PEI-g-PMOXA/PDA co-deposited film. Electroosmotic flow (EOF) mobility of the PEI-g-PMOXA/PDA-coated capillary was almost zero in a wide pH range (3.0-10.0), while the EOF mobility of bare capillary was much larger and increased significantly with pH increasing. When the PEI-g-PMOXA/PDA-coated capillary was exploited to separate a protein mixture including cytochrome c, lysozyme, ribonuclease A and α-chymotrypsinogen A, the theoretical plate numbers were of five orders of magnitude which were about ten-fold higher over those obtained with bare capillary; in addition, the RSD values of migration time were mostly less than 0.7% (30 consecutive runs) which were much smaller than those of bare capillary (c.a. 5.7%). The protein-resistant PEI-g-PMOXA/PDA-coated capillary was then used to investigate the interaction between APAP and BSA by FACE, the binding constant and number of binding sites at 25°C and pH 7.4 (Tris/HCl buffer of 25mM) were 1.39×10 4 M -1 and 1.08, respectively, which were comparable to the results determined by fluorescence spectroscopic measurement (3.18×10 4 M -1 and 1.19, respectively). Copyright © 2017 Elsevier B.V. All rights reserved.
The dynamics of magma chamber refilling at the Campi Flegrei caldera.
NASA Astrophysics Data System (ADS)
Montagna, Chiara Paola; Vassalli, Melissa; Longo, Antonella; Papale, Paolo; Giudice, Salvatore; Saccorotti, Gilberto
2010-05-01
The volcanologic and petrologic reconstructions of several eruptions during the last tens of thousand years of volcanism at the Campi Flegrei caldera show that in most cases a small, chemically evolved, partially degassed magma chamber was refilled by magma of deeper origin shortly before the eruption. New magma input in a shallow chamber is revealed from a variety of indicators, well described in the literature, that include major-trace element and isotope heterogeneities, and crystal-liquid disequilibria (e.g., Arienzo et al., Bull. Volcanol., 2009). In the case of the 4100 BP Agnano Monte Spina eruption, representing the highest intensity and magnitude event of the last epoch of activity, it has been suggested that the refilling occurred within a few tens of hours from the start of the eruption. Notably, in such a case the two end-member magmas that mixed shortly before eruption onset are not recognized as individual members in the deposits, rather, their composition and characteristics are reconstructed from small scale disequilibria, revealing that a relatively short time was sufficient for efficient mixing of the liquid components. In order to investigate the dynamics of magma chamber refilling and mixing at Campi Flegrei we have applied the GALES code (Longo et al., Geophys. Res. Lett., 2006) in a series of numerical simulations. The initial and boundary conditions have been defined in the frame of two subsequent projects coordinated by INGV and funded by the Italian Civil Protection Department, that gather a large number of experts on Campi Flegrei, and are consistent with the bulk of knowledge on the deep magmatic system. In all cases an initial compositional interface is placed at a certain depth, with non-degassed, buoyant magma placed below. The simulations investigate both the dynamics in a very large, 8 km deep reservoir revealed by seismic tomography (Zollo et al., Geophys. Res. Lett., 2008), and those in shallower and smaller chamber systems connected by dykes and representative of pre-eruptive conditions. The numerical results reveal the complex dynamics of magma mixing, dominated by the interplay between buoyant magma rise and dense magma sinking. In all simulated cases efficient mixing takes place at dyke levels, the buoyant magma entering the chamber is already a mixture of the two initial end-members, and the initial deep magma is never found as an individual component in the chamber. Over the time scale of our longest simulation (about 8 hours of real time), and with reference to the spatial resolution of our simulations (max 1 m), the magma chamber is occupied by a nearly homogeneous mixture of the two initial end-members, with minor but still visible density stratification continuously perturbed by the rise of small buoyant plumes. Consistent with the observations, an eruption occurring a few tens of hours after new magma ingression would be characterized by a magmatic composition intermediate between the two initial end-members, that can therefore be revealed only from small-scale heterogeneities and possibly from crystal-liquid disequilibria.
Hopson, Sari; Saverno, Kim; Liu, Larry Z; AL-Sabbagh, Ahmad; Orazem, John; Costantino, Mary E; Pasquale, Margaret K
2016-02-01
Biologic disease-modifying antirheumatic drug (DMARD) therapies are a mainstay of treatment for rheumatoid arthritis (RA), yet high member out-of-pocket (OOP) costs for such therapies may limit patient access to these therapies. To understand whether there is a relationship between OOP costs and the initial fill and subsequent refills of biologic DMARD treatments for RA members. Members of a national Medicare Advantage and Prescription Drug (MAPD) plan with an adjudicated (paid or reversed) claim for a biologic DMARD indicated for RA were identified from July 1, 2007, to December 31, 2012, and followed retrospectively. The first adjudicated claim date was the index date. Members were required to have 180 days of continuous enrollment pre- and post-index and ≥ 1 diagnosis for RA (ICD-9-CM: 714.0 or 714.2) during pre-index or ≤ 30 days post-index. Low-income subsidy and Medicaid-Medicare dual-eligible patients were excluded. The analysis used multivariate regression models to examine associations between initial prescription (Rx) abandonment rates and OOP costs and factors influencing the refill of a biologic DMARD therapy based on pharmacy claims. The final sample size included 864 MAPD members with an adjudicated claim for a biologic DMARD. The majority were female (77.4%) and mean age was 63.5 years (SD = 10.9). Most (78%) had conventional nonbiologic DMARD utilization during pre-index. The overall initial abandonment rate was 18.2% for biologic DMARDs, ranging from 1.3% for the lowest OOP cost group ($0-$250) to 32.7% for the highest OOP cost group (> $550; P < 0.0001 for Cochran-Armitage trend test). ORs for abandonment rose from 18.4 to 32.7 to 41.2 for OOP costs of $250.01-$400.00, $400.01-$550.00, and > $550.00 respectively, relative to OOP costs of ≤ $250.00 (all P < 0.0001). Meeting the catastrophic coverage limit and utilization of a specialty pharmacy for the index claim were both associated with a decreased likelihood of abandoning therapy (OR = 0.29 and OR = 0.14, respectively; both P < 0.05). Among the subset of 533 members with a paid claim, 82.4% had at least 1 refill post-index. The negative association between OOP cost and likelihood of refilling an Rx was highly significant (P < 0.0001). This study suggests that the higher the member OOP cost, the less likely an MAPD member is to initiate or refill a biologic DMARD therapy for RA. Further research is needed to understand reasons for initial Rx abandonment and lack of refills, including benefit design and adverse events.
Alhooshani, Khalid; Kim, Tae-Young; Kabir, Abuzar; Malik, Abdul
2005-01-07
A novel zirconia-based hybrid organic-inorganic sol-gel coating was developed for capillary microextraction (CME) (in-tube SPME). High degree of chemical inertness inherent in zirconia makes it very difficult to covalently bind a suitable organic ligand to its surface. In the present work, this problem was addressed from a sol-gel chemistry point of view. Principles of sol-gel chemistry were employed to chemically bind a hydroxy-terminated silicone polymer (polydimethyldiphenylsiloxane, PDMDPS) to a sol-gel zirconia network in the course of its evolution from a highly reactive alkoxide precursor undergoing controlled hydrolytic polycondensation reactions. A fused silica capillary was filled with a properly designed sol solution to allow for the sol-gel reactions to take place within the capillary for a predetermined period of time (typically 15-30 min). In the course of this process, a layer of the evolving hybrid organic-inorganic sol-gel polymer got chemically anchored to the silanol groups on the capillary inner walls via condensation reaction. At the end of this in-capillary residence time, the unbonded part of the sol solution was expelled from the capillary under helium pressure, leaving behind a chemically bonded sol-gel zirconia-PDMDPS coating on the inner walls. Polycyclic aromatic hydrocarbons, ketones, and aldehydes were efficiently extracted and preconcentrated from dilute aqueous samples using sol-gel zirconia-PDMDPS coated capillaries followed by thermal desorption and GC analysis of the extracted solutes. The newly developed sol-gel hybrid zirconia coatings demonstrated excellent pH stability, and retained the extraction characteristics intact even after continuous rinsing with a 0.1 M NaOH solution for 24 h. To our knowledge, this is the first report on the use of a sol-gel zirconia-based hybrid organic-inorganic coating as an extraction medium in solid phase microextraction (SPME).
Distribution of capillary transit times in isolated lungs of oxygen-tolerant rats.
Ramakrishna, Madhavi; Gan, Zhuohui; Clough, Anne V; Molthen, Robert C; Roerig, David L; Audi, Said H
2010-11-01
Rats pre-exposed to 85% O₂ for 5-7 days tolerate the otherwise lethal effects of 100% O₂. The objective was to evaluate the effect of rat exposure to 85% O₂ for 7 days on lung capillary mean transit time t(c) and distribution of capillary transit times (h(c)(t)). This information is important for subsequent evaluation of the effect of this hyperoxia model on the redox metabolic functions of the pulmonary capillary endothelium. The venous concentration vs. time outflow curves of fluorescein isothiocyanate labeled dextran (FITC-dex), an intravascular indicator, and coenzyme Q₁ hydroquinone (CoQ₁H₂), a compound which rapidly equilibrates between blood and tissue on passage through the pulmonary circulation, were measured following their bolus injection into the pulmonary artery of isolated perfused lungs from rats exposed to room air (normoxic) or 85% O₂ for 7 days (hyperoxic). The moments (mean transit time and variance) of the measured FITC-dex and CoQ₁H₂ outflow curves were determined for each lung, and were then used in a mathematical model [Audi et al. J. Appl. Physiol. 77: 332-351, 1994] to estimate t(c) and the relative dispersion (RD(c)) of h (c)(t). Data analysis reveals that exposure to hyperoxia decreases lung t(c) by 42% and increases RD(c), a measure h(c)(t) heterogeneity, by 40%.
Distribution of Capillary Transit Times in Isolated Lungs of Oxygen-Tolerant Rats
Ramakrishna, Madhavi; Gan, Zhuohui; Clough, Anne V.; Molthen, Robert C.; Roerig, David L.; Audi, Said H.
2014-01-01
Rats pre-exposed to 85% O2 for 5–7 days tolerate the otherwise lethal effects of 100% O2. The objective was to evaluate the effect of rat exposure to 85% O2 for 7 days on lung capillary mean transit time (t̄c) and distribution of capillary transit times (hc(t)). This information is important for subsequent evaluation of the effect of this hyperoxia model on the redox metabolic functions of the pulmonary capillary endothelium. The venous concentration vs. time outflow curves of fluorescein isothiocyanate labeled dextran (FITC-dex), an intravascular indicator, and coenzyme Q1 hydroquinone (CoQ1H2), a compound which rapidly equilibrates between blood and tissue on passage through the pulmonary circulation, were measured following their bolus injection into the pulmonary artery of isolated perfused lungs from rats exposed to room air (normoxic) or 85% O2 for 7 days (hyperoxic). The moments (mean transit time and variance) of the measured FITC-dex and CoQ1H2 outflow curves were determined for each lung, and were then used in a mathematical model [Audi et al. J. Appl. Physiol. 77: 332–351, 1994] to estimate t̄c and the relative dispersion (RDc) of hc(t). Data analysis reveals that exposure to hyperoxia decreases lung t̄c by 42% and increases RDc, a measure hc(t) heterogeneity, by 40%. PMID:20552277
Mukwaya, Anthony; Lennikov, Anton; Xeroudaki, Maria; Mirabelli, Pierfrancesco; Lachota, Mieszko; Jensen, Lasse; Peebo, Beatrice; Lagali, Neil
2018-05-01
Inflammation in the normally immune-privileged cornea can initiate a pathologic angiogenic response causing vision-threatening corneal neovascularization. Inflammatory pathways, however, are numerous, complex and are activated in a time-dependent manner. Effective resolution of inflammation and associated angiogenesis in the cornea requires knowledge of these pathways and their time dependence, which has, to date, remained largely unexplored. Here, using a model of endogenous resolution of inflammation-induced corneal angiogenesis, we investigate the time dependence of inflammatory genes in effecting capillary regression and the return of corneal transparency. Endogenous capillary regression was characterized by a progressive thinning and remodeling of angiogenic capillaries and inflammatory cell retreat in vivo in the rat cornea. By whole-genome longitudinal microarray analysis, early suppression of VEGF ligand-receptor signaling and inflammatory pathways preceded an unexpected later-phase preferential activation of LXR/RXR, PPARα/RXRα and STAT3 canonical pathways, with a concurrent attenuation of LPS/IL-1 inhibition of RXR function and Wnt/β-catenin signaling pathways. Potent downstream inflammatory cytokines such as Cxcl5, IL-1β, IL-6 and Ccl2 were concomitantly downregulated during the remodeling phase. Upstream regulators of the inflammatory pathways included Socs3, Sparc and ApoE. A complex and coordinated time-dependent interplay between pro- and anti-inflammatory signaling pathways highlights a potential anti-inflammatory role of LXR/RXR, PPARα/RXRα and STAT3 signaling pathways in resolving inflammatory corneal angiogenesis.
Makrlíková, Anna; Opekar, František; Tůma, Petr
2015-08-01
A computer-controlled hydrodynamic sample introduction method has been proposed for short-capillary electrophoresis. In the method, the BGE flushes sample from the loop of a six-way sampling valve and is carried to the injection end of the capillary. A short pressure impulse is generated in the electrolyte stream at the time when the sample zone is at the capillary, leading to injection of the sample into the capillary. Then the electrolyte flow is stopped and the separation voltage is turned on. This way of sample introduction does not involve movement of the capillary and both of its ends remain constantly in the solution during both sample injection and separation. The amount of sample introduced to the capillary is controlled by the duration of the pressure pulse. The new sample introduction method was tested in the determination of ammonia, creatinine, uric acid, and hippuric acid in human urine. The determination was performed in a capillary with an overall length of 10.5 cm, in two BGEs with compositions 50 mM MES + 5 mM NaOH (pH 5.1) and 1 M acetic acid + 1.5 mM crown ether 18-crown-6 (pH 2.4). A dual contactless conductivity/UV spectrometric detector was used for the detection. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Continuous-Flow Electrophoresis of DNA and Proteins in a Two-Dimensional Capillary-Well Sieve.
Duan, Lian; Cao, Zhen; Yobas, Levent
2017-09-19
Continuous-flow electrophoresis of macromolecules is demonstrated using an integrated capillary-well sieve arranged into a two-dimensional anisotropic array on silicon. The periodic array features thousands of entropic barriers, each resulting from an abrupt interface between a 2 μm deep well (channel) and a 70 nm capillary. These entropic barriers owing to two-dimensional confinement within the capillaries are vastly steep in relation to those arising from slits featuring one-dimensional confinement. Thus, the sieving mechanisms can sustain relatively large electric field strengths over a relatively small array area. The sieve rapidly sorts anionic macromolecules, including DNA chains and proteins in native or denatured states, into distinct trajectories according to size or charge under electric field vectors orthogonally applied. The baseline separation is achieved in less than 1 min within a horizontal migration length of ∼1.5 mm. The capillaries are self-enclosed conduits in cylindrical profile featuring a uniform diameter and realized through an approach that avoids advanced patterning techniques. The approach exploits a thermal reflow of a layer of doped glass for shape transformation into cylindrical capillaries and for controllably shrinking the capillary diameter. Lastly, atomic layer deposition of alumina is introduced for the first time to fine-tune the capillary diameter as well as to neutralize the surface charge, thereby suppressing undesired electroosmotic flows.
Chui, Toco Yuen Ping; Pinhas, Alexander; Gan, Alexander; Razeen, Moataz; Shah, Nishit; Cheang, Eric; Liu, Chun L; Dubra, Alfredo; Rosen, Richard B
2016-05-01
To characterise longitudinal changes in the retinal microvasculature of type 2 diabetes mellitus (T2DM) as exemplified in a patient with proliferative diabetic retinopathy (PDR) using an adaptive optics scanning light ophthalmoscope (AOSLO). A 35-year-old T2DM patient with PDR treated with scatter pan-retinal photocoagulation at the inferior retina 1 day prior to initial AOSLO imaging along with a 24-year-old healthy control were imaged in this study. AOSLO vascular structural and perfusion maps were acquired at four visits over a 20-week period. Capillary diameter and microaneurysm area changes were measured on the AOSLO structural maps. Imaging repeatability was established using longitudinal imaging of microvasculature in the healthy control. Capillary occlusion and recanalisation, capillary dilatation, resolution of local retinal haemorrhage, capillary hairpin formation, capillary bend formation, microaneurysm formation, progression and regression were documented over time in a region 2° superior to the fovea in the PDR patient. An identical microvascular network with same capillary diameter was observed in the control subject over time. High-resolution serial AOSLO imaging enables in vivo observation of vasculopathic changes seen in diabetes mellitus. The implications of this methodology are significant, providing the opportunity for studying the dynamics of the pathological process, as well as the possibility of identifying highly sensitive and non-invasive biomarkers of end organ damage and response to treatment. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guo Changjuan; Huang Zhengxu; Gao Wei
2008-01-15
We describe a homemade high-resolution orthogonal-injection time-of-flight (O-TOF) mass spectrometer combing a heated capillary inlet. The O-TOF uses a heated capillary tube combined with a radio-frequency only quadrupole (rf-only quadrupole) as an interface to help the ion transmission from the atmospheric pressure to the low-pressure regions. The principle, configuration of the O-TOF, and the performance of the instrument are introduced in this paper. With electrospray ion source, the performances of the mass resolution, the sensitivity, the mass range, and the mass accuracy are described. We also include our results obtained by coupling atmospheric pressure matrix-assisted laser deporption ionization with thismore » instrument.« less
NASA Astrophysics Data System (ADS)
Wu, Jixuan; Liu, Bo; Zhang, Hao; Song, Binbin
2017-11-01
A silica-capillary-based whispering gallery mode (WGM) microresonator has been proposed and experimentally demonstrated for the real-time monitoring of the polylysine adsorption process. The spectral characteristics of the WGM resonance dips with high quality factor and good wavelength selectivity have been investigated to evaluate the dynamic process for the binding of polylysine with a capillary surface. The WGM transmission spectrum shows a regular shift with increments of observation time, which could be exploited for the analysis of the polylysine adsorption process. The proposed WGM microresonator system possesses desirable qualities such as high sensitivity, fast response, label-free method, high detection resolution and compactness, which could find promising applications in histology and related bioengineering areas.
Capillary rise and swelling in cellulose sponges
NASA Astrophysics Data System (ADS)
Ha, Jonghyun; Kim, Jungchul; Kim, Ho-Young
2015-11-01
A cellulose sponge, which is a mundane example of a porous hydrophilic structure, can absorb and hold a significant amount of liquid. We present the results of experimental and theoretical investigation of the dynamics of the capillary imbibition of various aqueous solutions in the sponge that swells at the same time. We find that the rate of water rise against the resistance caused by gravitational and viscous effects deviates from Washburn's rule beyond a certain threshold height. We rationalize the novel power law of the rise height versus time by combining Darcy's law with hygroscopic swelling equation and also predict the threshold height. The scaling law constructed through this work agrees well with the experimental results, shedding light on the physics of capillary flow in deforming porous media.
Lin, Che-Hsin; Wang, Yao-Nan; Fu, Lung-Ming
2012-01-01
An integrated microfluidic chip is proposed for rapid DNA digestion and time-resolved capillary electrophoresis (CE) analysis. The chip comprises two gel-filled chambers for DNA enrichment and purification, respectively, a T-form micromixer for DNA/restriction enzyme mixing, a serpentine channel for DNA digestion reaction, and a CE channel for on-line capillary electrophoresis analysis. The DNA and restriction enzyme are mixed electroomostically using a pinched-switching DC field. The experimental and numerical results show that a mixing performance of 97% is achieved within a distance of 1 mm from the T-junction when a driving voltage of 90 V/cm and a switching frequency of 4 Hz are applied. Successive mixing digestion and capillary electrophoresis operation clearly present the changes on digesting φx-174 DNA in different CE runs. The time-resolved electropherograms show that the proposed device enables a φx-174 DNA sample comprising 11 fragments to be concentrated and analyzed within 24 min. Overall, the results presented in this study show that the proposed microfluidic chip provides a rapid and effective tool for DNA digestion and CE analysis applications. PMID:22662085
NASA Astrophysics Data System (ADS)
Ramachandran, A.; Leal, L. G.
2016-10-01
Using a scaling analysis, we assess the impact of interfacial slip on the time required for the thin liquid film between two drops undergoing a head-on collision to drain to the critical thickness for rupture by van der Waals forces. Interfacial slip is included in our continuum development using a Navier slip boundary condition, with the slip coefficient modeled using previous theories [Helfand and Tagami, J. Chem. Phys. 57, 1812 (1972), 10.1063/1.1678491; Goveas and Fredrickson, Eur. Phys. J. B 2, 79 (1998), 10.1007/s100510050228]. Slip decreases hydrodynamic resistance and speeds up film drainage. It renders the dependence of the drainage time on capillary number stronger in the spherical-film regime, but, interestingly, this dependence is altered only weakly in the dimpled-film regime. A subtle effect of slip is that it increases the range of capillary numbers in which the film remains predominantly spherical in shape during drainage (as opposed to being dimpled), leading to significantly faster drainage for these capillary numbers. Slip also leads to an increase in the critical capillary number beyond which coalescence is not possible in a head-collision.
Yin, Yue; Li, Gongyu; Guan, Yafeng; Huang, Guangming
2016-08-01
The flow rate match has been a great challenge when coupling capillary electrophoresis (CE) with electrospray ionization mass spectrometry (ESI-MS). Conventional CE-ESI-MS interfaces used liquid sheath flow, narrowed capillary or additional pressure to meet this requirement; sacrifice of either capillary inner diameter (i.d.) or separation efficiency is often inevitable. Thus, a regular-sized capillary-based sheathless interface would be attractive for flow rate match in CE-MS. The regular-sized capillary-based CE-MS interface was achieved by coupling CE with induced electrospray ionization (iESI) which was stimulated by the fact that the iESI could both achieve flow rate down to 0.2 μL/min and retain ionization efficiency. The CE-iESI-MS interface was completed with an intact separation capillary, outside the outlet end of which a metal electrode was attached for the application of alternating current (ac) high voltage (HV). The feasibility of this CE-iESI-MS interface was demonstrated through the stable total ion chromatograms obtained by continuous CE infusion of tripropylamine with regular-sized capillaries. Tripropylamine and atenolol were separated and detected successfully in phosphate buffer solution (PBS) by CE-iESI-MS using a 50 or 75 μm i.d. capillary. Furthermore, this new interface showed a better signal-to-noise (S/N) of 3 to 7 times enhancement compared with another sheathless CE-ESI-MS interface that using one high voltage for both separation and electrospray when analyzing the mixture of tripropylamine and proline in NH4 OAc buffer. In addition, the reproducibility of this interface gave satisfactory results with relative standard deviation (RSD) in retention time in the range between 1% and 3%. The novel sheathless CE-MS interface introduced here could match conventional electroosmotic flow (EOF) with electrospray which could also preserve the separation efficiency and sensitivity of CE-MS. This newly developed CE-iESI-MS interface was also demonstrated to be effective for different buffers, PBS and NH4 OAc, without any additives such as methanol and acetic acid. Hence, we believe that this sheathless CE-MS interface could be operated with other nonvolatile and volatile buffers. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Atomic-force-controlled capillary electrophoretic nanoprinting of proteins.
Lovsky, Yulia; Lewis, Aaron; Sukenik, Chaim; Grushka, Eli
2010-01-01
The general nanoprinting and nanoinjection of proteins on non-conducting or conducting substrates with a high degree of control both in terms of positional and timing accuracy is an important goal that could impact diverse fields from biotechnology (protein chips) to molecular electronics and from fundamental studies in cell biology to nanophotonics. In this paper, we combine capillary electrophoresis (CE), a separation method with considerable control of protein movement, with the unparalleled positional accuracy of an atomic force microscope (AFM). This combination provides the ability to electrophoretically or electroosmotically correlate the timing of protein migration with AFM control of the protein deposition at a high concentration in defined locations and highly confined volumes estimated to be 2 al. Electrical control of bovine serum albumin printing on standard protein-spotting glass substrates is demonstrated. For this advance, fountain pen nanolithography (FPN) that uses cantilevered glass-tapered capillaries is amended with the placement of electrodes on the nanopipette itself. This results in imposed voltages that are three orders of magnitude less than what is normally used in capillary electrophoresis. The development of atomic-force-controlled capillary electrophoretic printing (ACCEP) has the potential for electrophoretic separation, with high resolution, both in time and in space. The large voltage drop at the tip of the tapered nanopipettes allows for significant increases in concentration of protein in the small printed volumes. All of these attributes combine to suggest that this methodology should have a significant impact in science and technology.
Gallagher, Elyssia S.; Adem, Seid M.; Bright, Leonard K.; Calderon, Isen A. C.; Mansfield, Elisabeth; Aspinwall, Craig A.
2014-01-01
Protein separations in capillary zone electrophoresis (CZE) suffer from non-specific adsorption of analytes to the capillary surface. Semi-permanent phospholipid bilayers (PLBs) have been used to minimize adsorption, but must be regenerated regularly to ensure reproducibility. We investigated the formation, characterization, and use of hybrid phospholipid bilayers (HPBs) as more stable biosurfactant capillary coatings for CZE protein separations. HPBs are formed by covalently modifying a support with a hydrophobic monolayer onto which a self-assembled lipid monolayer is deposited. Monolayers prepared in capillaries using 3-cyanopropyldimethylchlorosilane (CPDCS) or n-octyldimethylchlorosilane (ODCS) yielded hydrophobic surfaces with lowered surface free energies of 6.0 ± 0.3 or 0.2 ± 0.1 mJ m−2, respectively, compared to 17 ± 1 mJ m−2 for bare silica capillaries. HPBs were formed by subsequently fusing vesicles comprised of 1,2-dilauroyl-sn-glycero-3-phosphocholine or 1,2-dioleoyl-sn-glycero-3-phosphocholine to CPDCS- or ODCS-modified capillaries. The resultant HPB coatings shielded the capillary surface and yielded reduced electroosmotic mobility (1.3 – 1.9 × 10−4 cm2 V−1s−1) compared to CPDCS- and ODCS-modified or bare capillaries (3.6 ± 0.2 × 10−4 cm2 V−1s−1, 4.8 ± 0.4 × 10−4 cm2 V−1s−1, and 6.0 ± 0.2 × 10−4 cm2 V−1s−1, respectively), with increased stability compared to PLB coatings. HPB-coated capillaries yielded reproducible protein migration times (RSD ≤ 3.6 %, n ≥ 6) with separation efficiencies as high as 200,000 plates m−1. PMID:24459085
Guiding of High Laser Intensities in Long Plasma Channels
NASA Astrophysics Data System (ADS)
Levin, M.; Eisenmann, S.; Palchan, T.; Zigler, A.; Sugiyama, K.; Nakajima, K.; Kaganovich, D.; Hubbard, R. F.; Ting, A.; Gordon, D. F.; Sprangle, P.; Fraenkel, M.; Maman, S.; Henis, Z.
Plasma channels have been widely used to guide intense laser pulses over many Rayleigh lengths. Using optimized segmented capillary discharges, we demonstrated guided propagation of ultra short (100 fs) high intensity (1016 W/cm-2, limited by the laser system) pulses over distances up to 12.6 cm and intensities above 1018W/cm2 for 1.5cm boron nitride capillary. Both radial and longitudinal density profiles of plasma channels were studied under various discharge conditions. A new diagnostic technique is presented in which the transport of a guided laser pulse at different delay times from the initiation of the discharge is sampled on a single discharge shot. Using external, 10 nsec Nd YAG laser of several tenths of milijoules to ignite polyethylene capillaries we have demonstrated channels of various length in density range of 1017 - 1019 cm-3 and up to 25% deep. The longitudinal profiles were found to be remarkably uniform in both short and long capillaries. The Boron Nitride capillary has provided a guiding medium that can withstand more than 1000 shots. Using these capillaries we have guided laser intensities above 1018W/cm2. The laser ignition of capillary discharge provided reliable almost jitter free approach. The concerns related to influence of relatively high current density flow through capillary on the injected electrons were studied extensively by us both theoretically and experimentally using a simple injection method. The method is based on the interaction of a high intensity laser pulse with a thin wire placed near capillary entrance. The influence of magnetic fields was found to be insignificant. Using this method we have studied transport of electrons though capillary discharge.
The application of capillary microsampling in GLP toxicology studies.
Verhaeghe, Tom; Dillen, Lieve; Stieltjes, Hans; Zwart, Loeckie de; Feyen, Bianca; Diels, Luc; Vroman, Ann; Timmerman, Philip
2017-04-01
Capillary microsampling (CMS) to collect microplasma volumes is gradually replacing traditional, larger volume sampling from rats in GLP toxicology studies. About 32 µl of blood is collected with a capillary, processed to plasma and stored in a 10- or 4-µl capillary which is washed out further downstream in the laboratory. CMS has been standardized with respect to materials, assay validation experiments and application for sample analysis. The implementation of CMS has resulted in blood volume reductions in the rat from 300 to 32 µl per time point and the elimination of toxicokinetic satellite groups in the majority of the rat GLP toxicology studies. The technique has been successfully applied in 26 GLP studies for 12 different projects thus far.
High-Performance Water-Iodinating Cartridge
NASA Technical Reports Server (NTRS)
Sauer, Richard; Gibbons, Randall E.; Flanagan, David T.
1993-01-01
High-performance cartridge contains bed of crystalline iodine iodinates water to near saturation in single pass. Cartridge includes stainless-steel housing equipped with inlet and outlet for water. Bed of iodine crystals divided into layers by polytetrafluoroethylene baffles. Holes made in baffles and positioned to maximize length of flow path through layers of iodine crystals. Resulting concentration of iodine biocidal; suppresses growth of microbes in stored water or disinfects contaminated equipment. Cartridge resists corrosion and can be stored wet. Reused several times before necessary to refill with fresh iodine crystals.
2014-06-02
thick-walled glass reactors fitted with ACE-threads under an argon atmosphere. The reactors were dried under vacuum then refilled with argon five times...were settled in individual dishes containing 10 ml of suspension at ~20°C on the laboratory benches. After 2 h the slides were exposed to a submerged ...and D20). This was done in order to see how the surfaces rearranged themselves after prolonged periods submerged in water, as would be the case on
Jang, Mi; Jeong, Seung-Weon; Kim, Bum-Keun; Kim, Jong-Chan
2015-01-01
Plant extracts have been used as herbal medicines to treat a wide variety of human diseases. We used response surface methodology (RSM) to optimize the Artemisia capillaris Thunb. extraction parameters (extraction temperature, extraction time, and ethanol concentration) for obtaining an extract with high anti-inflammatory activity at the cellular level. The optimum ranges for the extraction parameters were predicted by superimposing 4-dimensional response surface plots of the lipopolysaccharide- (LPS-) induced PGE2 and NO production and by cytotoxicity of A. capillaris Thunb. extracts. The ranges of extraction conditions used for determining the optimal conditions were extraction temperatures of 57–65°C, ethanol concentrations of 45–57%, and extraction times of 5.5–6.8 h. On the basis of the results, a model with a central composite design was considered to be accurate and reliable for predicting the anti-inflammation activity of extracts at the cellular level. These approaches can provide a logical starting point for developing novel anti-inflammatory substances from natural products and will be helpful for the full utilization of A. capillaris Thunb. The crude extract obtained can be used in some A. capillaris Thunb.-related health care products. PMID:26075271
Zwieniecki, Maciej A; Melcher, Peter J; Ahrens, Eric T
2013-01-01
We report results of an analysis of embolism formation and subsequent refilling observed in stems of Acer rubrum L. using magnetic resonance imaging (MRI). MRI is one of the very few techniques that can provide direct non-destructive observations of the water content within opaque biological materials at a micrometer resolution. Thus, it has been used to determine temporal dynamics and water distributions within xylem tissue. In this study, we found good agreement between MRI measures of pixel brightness to assess xylem liquid water content and the percent loss in hydraulic conductivity (PLC) in response to water stress (P50 values of 2.51 and 2.70 for MRI and PLC, respectively). These data provide strong support that pixel brightness is well correlated to PLC and can be used as a proxy of PLC even when single vessels cannot be resolved on the image. Pressure induced embolism in moderately stressed plants resulted in initial drop of pixel brightness. This drop was followed by brightness gain over 100 min following pressure application suggesting that plants can restore water content in stem after induced embolism. This recovery was limited only to current-year wood ring; older wood did not show signs of recovery within the length of experiment (16 h). In vivo MRI observations of the xylem of moderately stressed (~-0.5 MPa) A. rubrum stems revealed evidence of a spontaneous embolism formation followed by rapid refilling (~30 min). Spontaneous (not induced) embolism formation was observed only once, despite over 60 h of continuous MRI observations made on several plants. Thus this observation provide evidence for the presence of naturally occurring embolism-refilling cycle in A. rubrum, but it is impossible to infer any conclusions in relation to its frequency in nature.
Ude, Miriam; Schuessel, Katrin; Quinzler, Renate; Leuner, Kristina; Müller, Walter E; Schulz, Martin
2011-09-01
For treatment success in chronic diseases such as hypertension, adequate adherence to long-term pharmacotherapy is a prerequisite. The purpose of this study was to evaluate whether switching from brand name ramipril to a generic product after patent expiry may negatively affect patients' refill compliance. Claims data for ambulatory prescriptions within the statutory health insurance system were evaluated. Patients were included if they had filled a ramipril prescription (index) for either brand name or generic ramipril products between September 2003 and June 2004. Patients had to be continuously treated with ramipril for at least 12 months before and after the index date. Patients with a change from brand name to generic product or vice versa during follow-up after the index date were excluded from the analyses, as were patients who could not be unequivocally allocated to characteristics of covariates. Refill compliance was analysed by calculating the medication possession ratio (MPR), assuming that patients were prescribed one unit dose per day (MPR(UD)). In total, 142,690 and 79,191 patients were classified as brand name or generic therapy, respectively. Median MPR(UD) values were 0.95 and 0.96 (P < 0.001). In a logistic regression model adjusting for covariates, the probability for noncompliance (MPR(UD) < 0.8) was marginally lower in the generic compared with the brand name group (odds ratio 0.926, 99% confidence interval 0.901-0.951, P < 0.001). These results suggest that refill compliance is not negatively affected by a physician-induced switch from brand name to generic ramipril products after patent expiry.
Perruchoud, Christophe; Bovy, Michèle; Rutschmann, Blaise; Durrer, Anne; Buchser, Eric
2013-01-01
Intrathecal (IT) pump failures usually result in decreased drug administration and symptom reoccurrence with or without withdrawal syndrome. We report a case of a leaking silicone septum associated to a systemic drug overdose. An 84-year-old patient treated with IT clonidine for chronic back pain presented with a state of confusion, visual hallucinations, and hypertension two hours after an unremarkable pump (SynchroMed EL, Medtronic, Minneapolis, MN, USA) refill. The reservoir was emptied and 14 mL (8.4 mg of clonidine) was found to be missing (difference between retrieved and expected volumes). The pump was refilled and a check on the next day showed again a loss of 3.5 mL. A malfunction was suspected and the pump was replaced (SynchroMed II, Medtronic). The inspection of the external surface of the pump revealed severe damage to the silicone septum with multiple gouges due to needle scarring. A fluid leak also was clearly seen through the septum. The signs and symptoms presented by this patient are consistent with clonidine overdose that resulted from a combination of a possible accidental pocket fill and a definite septum leak into the subcutaneous tissue. The damage to the silicone could be due to the loss of the nontraumatic properties of the Huber needles that are rubbed against the metallic case in attempting to locate the injection port during refill procedures. This observation is the first description of a silicone septum damage contributing to a pump dysfunction and drug overdose despite the use of appropriate needles for refilling. © 2012 International Neuromodulation Society.
Liu, Yifei; Yang, Mei; Chao, Jingdong; Mulani, Parvez M
2010-08-01
Retail pharmacies provide regular prescription drugs and some specialty prescription drugs, whereas specialty pharmacies focus on distributing specialty prescription drugs, including tumor necrosis factor (TNF) antagonists. It is unknown whether pharmacy type impacts patients' adherence to anti-TNF therapy. The relationship between pharmacy type (specialty vs. retail) and refill adherence to therapy with the TNF antagonist adalimumab was examined. This was a retrospective analysis of dispensing records of patients in the United States who were prescribed a TNF antagonist (adalimumab 40 mg per 0.8-mL injection) during a dispensation period from January 2003 to August 2009. Patients treated with adalimumab were included in the analysis regardless of diagnosis. For each patient, medication refill adherence (MRA) was calculated as total days of supply divided by total number of days evaluated, multiplied by 100. A regression analysis was conducted in which the dependent variable was MRA and the independent variables included pharmacy type (specialty vs. retail pharmacy), reimbursement/payment type, copayment/payment amount per prescription, age, sex, ethnicity, and annual income. Of the 86,079 patients included, 70% obtained the medication from a specialty pharmacy, 92% were members of Blue Cross and Blue Shield plans, 67% were women, and 81% were white. The average MRA was 84, and the average age was 52 years. Significant predictors (P<0.05) of MRA included pharmacy type, reimbursement/payment type, copayment/payment amount per prescription, age, sex, and ethnicity; and pharmacy type was the strongest predictor. When other independent variables were controlled for, MRA was 16% less for patients who used a retail pharmacy vs. patients who used a specialty pharmacy. Patients who used a specialty pharmacy to fulfill prescriptions for a TNF antagonist had a greater refill adherence than did patients who used a retail pharmacy.
Hero, Christel; Eliasson, Björn; Franzén, Stefan; Svensson, Ann‐Marie; Miftaraj, Mervete; Gudbjörnsdottir, Soffia; Eeg‐Olofsson, Katarina; Andersson Sundell, Karolina
2017-01-01
Abstract Purpose This study aimed to describe and compare refill adherence and persistence to lipid‐lowering medicines in patients with type 2 diabetes by previous cardiovascular disease (CVD). Methods We followed 97 595 patients (58% men; 23% with previous CVD) who were 18 years of age or older when initiating lipid‐lowering medicines in 2007–2010 until first fill of multi‐dose dispensed medicines, death, or 3 years. Using personal identity numbers, we linked individuals' data from the Swedish Prescribed Drug Register, the Swedish National Diabetes Register, the National Patient Register, the Cause of Death Register, and the Longitudinal Integration Database for Health Insurance and Labour Market Studies. We assessed refill adherence using the medication possession ratio (MPR) and the maximum gap method, and measured persistence from initiation to discontinuation of treatment or until 3 years after initiation. We analyzed differences in refill adherence and persistence by previous CVD in multiple regression models, adjusted for socioeconomic status, concurrent medicines, and clinical characteristics. Results The mean age of the study population was 64 years, 80% were born in Sweden, and 56% filled prescriptions for diabetes medicines. Mean MPR was 71%, 39% were adherent according to the maximum gap method, and mean persistence was 758 days. Patients with previous CVD showed higher MPR (3%) and lower risk for discontinuing treatment (12%) compared with patients without previous CVD (P < 0.0001). Conclusions Patients with previous CVD were more likely to be adherent to treatment and had lower risk for discontinuation compared with patients without previous CVD. PMID:28799214
Calcium store refilling and STIM activation in STIM- and Orai-deficient cell lines.
Zheng, Sisi; Zhou, Lijuan; Ma, Guolin; Zhang, Tian; Liu, Jindou; Li, Jia; Nguyen, Nhung T; Zhang, Xiaoyan; Li, Wanjie; Nwokonko, Robert; Zhou, Yandong; Zhao, Fukuan; Liu, Jingguo; Huang, Yun; Gill, Donald L; Wang, Youjun
2018-06-22
Mediated through the combined action of STIM proteins and Orai channels, store-operated Ca 2+ entry (SOCE) functions ubiquitously among different cell types. The existence of multiple STIM and Orai genes has made it difficult to assign specific roles of each STIM and Orai homolog in mediating Ca 2+ signals. Using CRISPR/Cas9 gene editing tools, we generated cells with both STIM or all three Orai homologs deleted and directly monitored store Ca 2+ and Ca 2+ signals. We found that unstimulated, SOCE null KO cells still retain 50~70% of ER Ca 2+ stores of wildtype (wt) cells. After brief exposure to store-emptying conditions, acute refilling of ER Ca 2+ stores was totally blocked in KO cells. However, after 24 h in culture, stores were eventually refilled. Thus, SOCE is critical for immediate refilling of ER Ca 2+ but is dispensable for the maintenance of long-term ER Ca 2+ homeostasis. Using the Orai null background triple Orai-KO cells, we examined the plasma membrane translocation properties of a series of truncated STIM1 variants. FRET analysis reveals that, even though PM tethering of STIM1 expedites the activation of STIM1 by facilitating its oligomerization, migration, and accumulation in ER-PM junctions, it is not required for the conformational switch, oligomerization, and clustering of STIM1. Even without overt puncta formation at ER-PM junctions, STIM1 1-491 and STIM1 1-666 could still rescue SOCE when expressed in STIM KO cells. Thus, ER-PM trapping and clustering of STIM molecules only facilitates the process of SOCE activation, but is not essential for the activation of Orai channels.
Zwieniecki, Maciej A.; Melcher, Peter J.; Ahrens, Eric T.
2013-01-01
We report results of an analysis of embolism formation and subsequent refilling observed in stems of Acer rubrum L. using magnetic resonance imaging (MRI). MRI is one of the very few techniques that can provide direct non-destructive observations of the water content within opaque biological materials at a micrometer resolution. Thus, it has been used to determine temporal dynamics and water distributions within xylem tissue. In this study, we found good agreement between MRI measures of pixel brightness to assess xylem liquid water content and the percent loss in hydraulic conductivity (PLC) in response to water stress (P50 values of 2.51 and 2.70 for MRI and PLC, respectively). These data provide strong support that pixel brightness is well correlated to PLC and can be used as a proxy of PLC even when single vessels cannot be resolved on the image. Pressure induced embolism in moderately stressed plants resulted in initial drop of pixel brightness. This drop was followed by brightness gain over 100 min following pressure application suggesting that plants can restore water content in stem after induced embolism. This recovery was limited only to current-year wood ring; older wood did not show signs of recovery within the length of experiment (16 h). In vivo MRI observations of the xylem of moderately stressed (~-0.5 MPa) A. rubrum stems revealed evidence of a spontaneous embolism formation followed by rapid refilling (~30 min). Spontaneous (not induced) embolism formation was observed only once, despite over 60 h of continuous MRI observations made on several plants. Thus this observation provide evidence for the presence of naturally occurring embolism-refilling cycle in A. rubrum, but it is impossible to infer any conclusions in relation to its frequency in nature. PMID:23885258
Tater, Kathy Chu; Cole, William Elliott; Pion, Paul David
2017-08-01
Poor adherence to continuing allergen-specific immunotherapy treatment (ASIT) may be an issue in veterinary medicine. No studies describe how allergen tests are used in general veterinary practice, including the percentage of patients that receive ASIT after allergen testing. Assess veterinary ASIT patterns in United States general practices. Dogs (n = 2,557) and 121 cats allergen-tested at 177 hospitals (173 general practice and four specialty practices) in 44 states. Invoiced service descriptions of allergen tests and ASIT orders were retrieved from an aggregated database of veterinary practices. In general practice, 42% (992 of 2,360) of patients did not begin ASIT after allergen testing. ASIT was not refilled for 29% (398 of 1,368) of patients after the initial order. ASIT was initiated and refilled more often in dogs (56.6%, 71.4%, respectively) than cats (38%, 67.4%). Specialty practice patients had the highest ASIT initiation (94.4%) and refill (92.7%) percentages in comparison to general practices (P < 0.001). Size, age, geographical region and type of practice were associated with whether dogs were started on ASIT. Geographical region was also associated with refilling a prescription for ASIT, which was considered to be evidence of adherence to continuing treatment. Almost one third of clients failed to continue ASIT beyond the initial order, which is a much shorter duration of therapy than the 12 months recommended for determining ASIT efficacy. A large number of general practice patients did not begin ASIT after allergen testing, likely due to differences in how clinicians in general and dermatology practices use allergen tests. © 2017 ESVD and ACVD.
USDA-ARS?s Scientific Manuscript database
Successful monitoring of pollutant transport through the soil profile requires accurate, reliable, and appropriate instrumentation to measure amount of drainage water or flux within the vadose layer. We evaluated the performance and accuracy of automated passive capillary wick samplers (PCAPs) for ...
Wang, Jianhao; Qin, Yuqin; Qin, Haifang; Liu, Li; Ding, Shumin; Teng, Yiwan; Ji, Junling; Qiu, Lin; Jiang, Pengju
2016-08-01
Herein, we have developed an in-capillary assay for simultaneous detection of the assembly and disassembly of the multivalent HA tag peptide and antibody. HA tag with hexahistidine at C terminus (YPYDVPDYAG4 H6 , termed YPYDH6 ) was conjugated with quantum dots (QDs) by metal-affinity force to form a multivalent HA tag (QD-YPYDH6 ). QD-YPYDH6 and monoclonal anti-HA antibody (anti-HA) were sequentially injected into the capillary. They were mixed and assembled inside the capillary. The reaction products were online discriminated and detected by fluorescence coupled capillary electrophoresis (CE-FL). For the in-capillary assay, the binding efficiency of the multivalent HA tag and antibody on was influenced by the molar ratio and injection time. Such novel assay could even give out the self-assembly kinetic constant of QDs and YPYDH6 as KD of 34.1 μM with n (binding cooperativeness) of 2.2 by Hill equation. More importantly, the simultaneous detection of the assembly and imidazole (Im) induced disassembly of the QD-YPYDH6 -anti-HA complex was achieved in a single in-capillary assay. Our study demonstrated a new method for the online detection of antigen-antibody interactions. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Visual detection of multiple genetically modified organisms in a capillary array.
Shao, Ning; Chen, Jianwei; Hu, Jiaying; Li, Rong; Zhang, Dabing; Guo, Shujuan; Hui, Junhou; Liu, Peng; Yang, Litao; Tao, Sheng-Ce
2017-01-31
There is an urgent need for rapid, low-cost multiplex methodologies for the monitoring of genetically modified organisms (GMOs). Here, we report a C[combining low line]apillary A[combining low line]rray-based L[combining low line]oop-mediated isothermal amplification for M[combining low line]ultiplex visual detection of nucleic acids (CALM) platform for the simple and rapid monitoring of GMOs. In CALM, loop-mediated isothermal amplification (LAMP) primer sets are pre-fixed to the inner surface of capillaries. The surface of the capillary array is hydrophobic while the capillaries are hydrophilic, enabling the simultaneous loading and separation of the LAMP reaction mixtures into each capillary by capillary forces. LAMP reactions in the capillaries are then performed in parallel, and the results are visually detected by illumination with a hand-held UV device. Using CALM, we successfully detected seven frequently used transgenic genes/elements and five plant endogenous reference genes with high specificity and sensitivity. Moreover, we found that measurements of real-world blind samples by CALM are consistent with results obtained by independent real-time PCRs. Thus, with an ability to detect multiple nucleic acids in a single easy-to-operate test, we believe that CALM will become a widely applied technology in GMO monitoring.
Hernández, Glenn; Cavalcanti, Alexandre Biasi; Ospina-Tascón, Gustavo; Zampieri, Fernando Godinho; Dubin, Arnaldo; Hurtado, F Javier; Friedman, Gilberto; Castro, Ricardo; Alegría, Leyla; Cecconi, Maurizio; Teboul, Jean-Louis; Bakker, Jan
2018-04-23
Septic shock is a highly lethal condition. Early recognition of tissue hypoperfusion and its reversion are key factors for limiting progression to multiple organ dysfunction and death. Lactate-targeted resuscitation is the gold-standard under current guidelines, although it has several pitfalls including that non-hypoxic sources of lactate might predominate in an unknown proportion of patients. Peripheral perfusion-targeted resuscitation might provide a real-time response to increases in flow that could lead to a more timely decision to stop resuscitation, thus avoiding fluid overload and the risks of over-resuscitation. This article reports the rationale, study design and analysis plan of the ANDROMEDA-SHOCK Study. ANDROMEDA-SHOCK is a randomized controlled trial which aims to determine if a peripheral perfusion-targeted resuscitation is associated with lower 28-day mortality compared to a lactate-targeted resuscitation in patients with septic shock with less than 4 h of diagnosis. Both groups will be treated with the same sequential approach during the 8-hour study period pursuing normalization of capillary refill time versus normalization or a decrease of more than 20% of lactate every 2 h. The common protocol starts with fluid responsiveness assessment and fluid loading in responders, followed by a vasopressor and an inodilator test if necessary. The primary outcome is 28-day mortality, and the secondary outcomes are: free days of mechanical ventilation, renal replacement therapy and vasopressor support during the first 28 days after randomization; multiple organ dysfunction during the first 72 h after randomization; intensive care unit and hospital lengths of stay; and all-cause mortality at 90-day. A sample size of 422 patients was calculated to detect a 15% absolute reduction in mortality in the peripheral perfusion group with 90% power and two-tailed type I error of 5%. All analysis will follow the intention-to-treat principle. If peripheral perfusion-targeted resuscitation improves 28-day mortality, this could lead to simplified algorithms, assessing almost in real-time the reperfusion process, and pursuing more physiologically sound objectives. At the end, it might prevent the risk of over-resuscitation and lead to a better utilization of intensive care unit resources. Trial registration ClinicalTrials.gov Identifier: NCT03078712 (registered retrospectively March 13th, 2017).
Qiu, Fen; Tian, Hui; Zhang, Zhi; Yuan, Xian-Ling; Tan, Yuan-Feng; Ning, Xiao-Qing
2013-10-01
To study the effects of hemostasis, analgesic and anti inflammation of the alcohol extract of Hibiscus tiliaceus and offer pharmacological and experimental basis for its safe and effective use in clinic. The effects of hemostasist were observed with tail breaking method, capillary tube method and slide method; Hot board and body distortion induced by acetic acid methods were applied in mice analgesia experiment, the mice model of acute auricle swelling induced by dmi ethylbenzene and capillary permeability induced by acetic acid were applied to observe the anti inflammatory effects. The alcohol extract of Hibiscus tiliaceus could significantly reduce the bleeding time and the clotting time, delay the plant reaction time and reduce the writhing times of the mice, and it also had effect on inhibiting swelling of mice ear and the permeability of the capillary. These results suggest that the alcohol extract of Hibiscus tiliaceus has the effects of hemostasis, analgesic and anti inflammation.
NASA Astrophysics Data System (ADS)
Woith, Heiko; Chiodini, Giovanni; Mangiacapra, Annarita; Wang, Rongjiang
2016-04-01
The hydrothermal system beneath Campi Flegrei is strongly affected by sub-surface processes as manifested by a geothermal "plume" below Solfatara, associated with the formation of mud-pools (Fangaia), fumaroles (Bocca Grande, Pisciarelli), and thermal springs (Agnano). Within the frame of MED-SUV (The MED-SUV project has received funding from the European Union Seventh Framework Programme FP7 under Grant agreement no 308665), pressure transients in the hydrothermal system of Campi Flegrei are being continuously monitored at fumaroles, mudpools, hot springs, and geothermal wells. In total, waterlevel and temperature is recorded at 8 sites across the hydrothermal plume along a profile aligned between Agnano Termal in the East and Fangaia in the West. Autonomous devices are used to record the water level and water temperature at 10 minute intervals. At Fangaia mudpool water level and water temperature are dominantly controlled by rain water. Thus, the pool is refilled episodically. Contrary, the water level at a well producing hot water (82°C) for the Pisciarelli tennis club drops and recovers at nearly regular intervals. The induced water level changes are of the order of 1-2m and 3-4m in case of the mudpool and the hot-water-well, respectively. At first glance, both monitoring sites might seem to be fully useless to access natural changes in the Campi Flegrei fluid system. At a second thought, both timeseries provide a unique opportunity to monitor potential permeability changes in the aquifer system. A similar approach had been proposed to deduce earthquake-related permeability changes from Earth tide variations. Contrary to the indirect Earth tide approach, we have the chance to estimate the hydraulic aquifer properties from our monitoring data directly, since each time series contains a sequence of discrete hydraulic tests - namely drawdown tests and refill experiments. Although our Cooper-Jacob approach is really crude, we obtained reasonable permeability estimates for both sites. Preliminary permeability timeseries are presented.
Horvat, Nejc; Kos, Mitja
2015-02-01
To assess patients' knowledge about prescription medicines they are taking and their view on how much community pharmacist counseling contributed to their knowledge. An observational study was designed to obtain information about patients' knowledge, their view on pharmacist counseling, and physicians'/pharmacists' provision of information. This study used a specifically designed questionnaire, which served as an interview guide. 400 patients picking up a prescription medicine were structurally interviewed upon leaving one of the 20 randomly chosen Slovenian pharmacies. The interviews took place in November and December 2013. Patients were familiar with general information about the medicines and their application (93%-100% of patients). Knowledge about considerations (16% of patients) and adverse effects (20% of patients) was limited. Factors associated with patient knowledge were physicians'/pharmacists' adequate provision of information (β=0.259), patient's age (β=- 0.149), patient's education (β=0.100), and prescription type (β=-0.104). Patients' responses were mostly consistent with the Summaries of Product Characteristics (72%-96% of responses). However, 42% of responses to the question about taking medicine with meals were incorrect. Pharmacists routinely informed the patients about medication purpose, dose, application rate, and timing of medication (in 72%, 89%, 89%, and 77% of cases, respectively). Other information was rarely offered. Patients with new prescriptions received significantly more counseling (pharmacist counseling score 5.9, 5.2, and 4.7 of maximum 10 for new, regular, and refill prescriptions, respectively, P=0.001) and obtained adequate labeling (69%, 26%, and 17% of patients for new, regular and refill prescriptions, respectively, P<0.001) than patients with regular or refill prescriptions. Patients were familiar with basic information about administration of their prescription medicines, but lacked knowledge about medication safety. This could be attributed to pharmacist counseling, which primarily focused on medicine use instructions.
Horvat, Nejc; Kos, Mitja
2015-01-01
Aim To assess patients’ knowledge about prescription medicines they are taking and their view on how much community pharmacist counseling contributed to their knowledge. Methods An observational study was designed to obtain information about patients’ knowledge, their view on pharmacist counseling, and physicians’/pharmacists’ provision of information. This study used a specifically designed questionnaire, which served as an interview guide. 400 patients picking up a prescription medicine were structurally interviewed upon leaving one of the 20 randomly chosen Slovenian pharmacies. The interviews took place in November and December 2013. Results Patients were familiar with general information about the medicines and their application (93%-100% of patients). Knowledge about considerations (16% of patients) and adverse effects (20% of patients) was limited. Factors associated with patient knowledge were physicians’/pharmacists’ adequate provision of information (β = 0.259), patient’s age (β = - 0.149), patient’s education (β = 0.100), and prescription type (β = -0.104). Patients’ responses were mostly consistent with the Summaries of Product Characteristics (72%-96% of responses). However, 42% of responses to the question about taking medicine with meals were incorrect. Pharmacists routinely informed the patients about medication purpose, dose, application rate, and timing of medication (in 72%, 89%, 89%, and 77% of cases, respectively). Other information was rarely offered. Patients with new prescriptions received significantly more counseling (pharmacist counseling score 5.9, 5.2, and 4.7 of maximum 10 for new, regular, and refill prescriptions, respectively, P = 0.001) and obtained adequate labeling (69%, 26%, and 17% of patients for new, regular and refill prescriptions, respectively, P < 0.001) than patients with regular or refill prescriptions. Conclusion Patients were familiar with basic information about administration of their prescription medicines, but lacked knowledge about medication safety. This could be attributed to pharmacist counseling, which primarily focused on medicine use instructions. PMID:25727041
Measurement of surface tension and viscosity by open capillary techniques
Rye,Robert R. , Yost,Frederick G.
1998-01-01
An open-channel capillary is provided, having preferably a v-shaped groove in a flat wettable surface. The groove has timing marks and a source marker in which the specimen to be tested is deposited. The time of passage between the timing marks is recorded, and the ratio of surface tension .gamma. to viscosity .mu. is determined from the equation given below: ##EQU1## where h.sub.0 is the groove depth, .alpha. is the groove angle, .theta. is the liquid/solid contact angle, and t is the flow time. It has been shown by the
Toxicological and analytical assessment of e-cigarette refill components on airway epithelia.
Singh, Jasjot; Luquet, Emilie; Smith, David P T; Potgieter, Herman J; Ragazzon, Patricia
2016-12-01
There are over 2.6 million users of e-cigarettes in the United Kingdom alone as they have been promoted as a safer alternative to traditional cigarettes. The addition of flavours and aromas has also proven to be popular with younger generations. In this review, we survey the range of studies in the short timeframe since e-cigarettes reached the market to draw attention to the health associated risks and benefits of their introduction. We complement this review with a case study reporting on the composition of selected e-cigarette refills with particular emphasis on the toxicological activity of its components on lung cells.
2016-11-02
This final rule implements section 702 (c) of the Carl Levin and Howard P. "Buck" McKeon National Defense Authorization Act for Fiscal Year 2015 which states that beginning October 1, 2015, the pharmacy benefits program shall require eligible covered beneficiaries generally to refill non-generic prescription maintenance medications through military treatment facility pharmacies or the national mail-order pharmacy program. An interim final rule is in effect. Section 702(c) of the National Defense Authorization Act for Fiscal Year 2015 also terminates the TRICARE For Life Pilot Program on September 30, 2015. The TRICARE For Life Pilot Program described in section 716(f) of the National Defense Authorization Act for Fiscal Year 2013, was a pilot program which began in March 2014 requiring TRICARE For Life beneficiaries to refill non-generic prescription maintenance medications through military treatment facility pharmacies or the national mail-order pharmacy program. TRICARE for Life beneficiaries are those enrolled in the Medicare wraparound coverage option of the TRICARE program. This rule includes procedures to assist beneficiaries in transferring covered prescriptions to the mail order pharmacy program.
2016-01-01
Multiplex polymerase chain reaction (PCR) has been widely utilized for high-throughput pathogen identification. Often, a dye is used to intercalate the amplified DNA fragments, and identifications of the pathogens are carried out by DNA melting curve analysis or gel electrophoresis. Integrating DNA amplification and identification is a logic path toward maximizing the benefit of multiplex PCR. Although PCR and gel electrophoresis have been integrated, replenishing the gels after each run is tedious and time-consuming. In this technical note, we develop an approach to address this issue. We perform multiplex PCR inside a capillary, transfer the amplified fragments to a bare narrow capillary, and measure their lengths online using bare narrow capillary–hydrodynamic chromatography (BaNC-HDC), a new technique recently developed in our laboratory for free-solution DNA separation. To intercalate the DNA with YOYO-1 (a fluorescent dye) for BaNC-HDC, we flush the capillary column with a YOYO-1 solution; positively charged YOYO-1 is adsorbed (or charged) onto the negatively charged capillary wall. As DNA molecules are driven down the column for separation, they react with the YOYO-1 stored on the capillary wall and are online-intercalated with the dye. With a single YOYO-1 charging, the column can be used for more than 40 runs, although the fluorescence signal intensities of the DNA peaks decrease gradually. Although the dye-DNA intercalation occurs during the separation, it does not affect the retention times, separation efficiencies, or resolutions. PMID:25555111
Refinetti, Paulo; Morgenthaler, Stephan; Ekstrøm, Per O
2016-07-01
Cycling temperature capillary electrophoresis has been optimised for mutation detection in 76% of the mitochondrial genome. The method was tested on a mixed sample and compared to mutation detection by next generation sequencing. Out of 152 fragments 90 were concordant, 51 discordant and in 11 were semi-concordant. Dilution experiments show that cycling capillary electrophoresis has a detection limit of 1-3%. The detection limit of routine next generation sequencing was in the ranges of 15 to 30%. Cycling temperature capillary electrophoresis detect and accurate quantify mutations at a fraction of the cost and time required to perform a next generation sequencing analysis. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Capillary red blood cell velocimetry by phase-resolved optical coherence tomography.
Tang, Jianbo; Erdener, Sefik Evren; Fu, Buyin; Boas, David A
2017-10-01
We present a phase-resolved optical coherence tomography (OCT) method to extend Doppler OCT for the accurate measurement of the red blood cell (RBC) velocity in cerebral capillaries. OCT data were acquired with an M-mode scanning strategy (repeated A-scans) to account for the single-file passage of RBCs in a capillary, which were then high-pass filtered to remove the stationary component of the signal to ensure an accurate measurement of phase shift of flowing RBCs. The angular frequency of the signal from flowing RBCs was then quantified from the dynamic component of the signal and used to calculate the axial speed of flowing RBCs in capillaries. We validated our measurement by RBC passage velocimetry using the signal magnitude of the same OCT time series data.
Mondal, Samir K; Mitra, Anupam; Singh, Nahar; Sarkar, S N; Kapur, Pawan
2009-10-26
We propose a technique of chemical etching for fabrication of near perfect optical fiber nanoprobe (NNP). It uses photosensitive single mode optical fiber to etch in hydro fluoric (HF) acid solution. The difference in etching rate for cladding and photosensitive core in HF acid solution creates capillary ring along core-cladding boundary under a given condition. The capillary ring is filled with acid solution due to surface tension and capillary action. Finally it creates near perfect symmetric tip at the apex of the fiber as the height of the acid level in capillary ring decreases while width of the ring increases with continuous etching. Typical tip features are short taper length (approximately 4 microm), large cone angle (approximately 38 degrees ), and small probe tip dimension (<100 nm). A finite difference time domain (FDTD) analysis is also presented to compare near field optics of the NNP with conventional nanoprobe (CNP). The probe may be ideal for near field optical imaging and sensor applications.
USDA-ARS?s Scientific Manuscript database
Background: Conventional immunoblot assays are a very useful tool for specific protein identification, but are tedious, labor-intensive and time-consuming. An automated capillary electrophoresis-based immunoblot assay called "Simple Western" has recently been developed that enables the protein sepa...
Separation of delta-, gamma- and alpha-tocopherols by CEC.
Fanali, Salvatore; Catarcini, Paolo; Quaglia, Maria Giovanna; Camera, Emanuela; Rinaldi, Mariarosa; Picardo, Mauro
2002-08-01
In this study capillary electrochromatography (CEC) was used for the separation of three tocopherols (TOHs), namely delta-, gamma- and alpha-TOH and the antioxidant compound, butylated hydroxytoluene (BHT). The CEC experiments were carried out using an octadecylsilica (ODS) stationary phase packed, in our laboratory, in a fused-silica capillary (100 microm I.D., 365 microm O.D. x 33 cm of total length and 24.6 or 8.4 cm effective length). The mobile phase was composed by a mixture of methanol (MeOH) and acetonitrile (ACN), at different concentrations and 0.01% (w/v) of ammonium acetate. Retention time (t(R)), retention factor (k), resolution (R(s)) of the three TOHs were strongly influenced by the organic solvent composition of the run buffer and by the effective length of the capillary. Optimum experimental conditions were found even employing the short effective length of the capillary achieving the baseline separation of the studied analytes in a relatively short time (less than 5 min). The optimized method was applied to the qualitative analysis of vitamin E (alpha-TOH) present in a human serum extract.
Ebmeier, S J; Barker, M; Bacon, M; Beasley, R C; Bellomo, R; Knee Chong, C; Eastwood, G M; Gilchrist, J; Kagaya, H; Pilcher, J; Reddy, S K; Ridgeon, E; Sarma, N; Sprogis, S; Tanaka, A; Tweedie, M; Weatherall, M; Young, P J
2018-05-01
The influence of variables that might affect the accuracy of pulse oximetry (SpO2) recordings in critically ill patients is not well established. We sought to describe the relationship between paired SpO2/SaO2 (oxygen saturation via arterial blood gas analysis) in adult intensive care unit (ICU) patients and to describe the diagnostic performance of SpO2 in detecting low SaO2 and PaO2. A paired SpO2/SaO2 measurement was obtained from 404 adults in ICU. Measurements were used to calculate bias, precision, and limits of agreement. Associations between bias and variables including vasopressor and inotrope use, capillary refill time, hand temperature, pulse pressure, body temperature, oximeter model, and skin colour were estimated. There was no overall statistically significant bias in paired SpO2/SaO2 measurements; observed limits of agreement were +/-4.4%. However, body temperature, oximeter model, and skin colour, were statistically significantly associated with the degree of bias. SpO2 <89% had a sensitivity of 3/7 (42.9%; 95% confidence intervals, CI, 9.9% to 81.6%) and a specificity of 344/384 (89.6%; 95% CI 86.1% to 92.5%) for detecting SaO2 <89%. The absence of statistically significant bias in paired SpO2/SaO2 in adult ICU patients provides support for the use of pulse oximetry to titrate oxygen therapy. However, SpO2 recordings alone should be used cautiously when SaO2 recordings of 4.4% higher or lower than the observed SpO2 would be of concern. A range of variables relevant to the critically ill had little or no effect on bias.
Illiteracy and diabetic foot complications.
Al-Kaabi, Juma M; Al Maskari, Fatma; Cragg, Paul; Afandi, Bachar; Souid, Abdul-Kader
2015-12-01
Diabetes is especially common in the United Arab Emirates. Its complications in patients residing in the region have yet to be fully explored. This study reports on foot problems in our diabetic patients, with emphasis on the impact of illiteracy on foot care and complications due to diabetes. Adults were randomly recruited from the Diabetes Center at Tawam-John Hopkins affiliated hospital. A questionnaire addressing foot care and problems was completed for all patients. In addition, an examination was performed by a trained nurse, an endocrinologist, and a podiatrist. Four hundred twenty-two adults with type 2 (93%) or type 1 (7%) diabetes were enrolled; 67% were females. Patients' mean age was 52 ± 13 years and duration of diabetes ≥ 1 year. Illiterate patients were 51% and were less likely to practice foot care (p=0.002), recognize foot risk factors (p=0.004), use proper footwear (p=0.010), and being physically active (p<0.001). In addition, they were more likely to have diabetic complications, such as neuropathy (p=0.027), eye disease (p=0.032), hypertension (p<0.001), obesity (p=0.003), increased body fat percentage (p<0.001), reduced capillary refill time (p=0.002), reduced monofilament (p=0.003), and reduced vibration (p<0.001). Logistic regression analysis revealed literates [OR=2.4, CI=1.1-5.4, p=0.031], female gender [OR=2.7, CI=1.1-6.2, p=0.023], and history of foot ulcer [OR=6.0, CI=2.1-17.2, p=0.001] were predictors of practicing foot care. Illiteracy invoked significant challenges to diabetic attentiveness and imposed increased foot complications. Physicians should realize that illiterate patients are vulnerable and require effective strategies to improve their education about the disease and reduce their diabetic complications. Copyright © 2015 Primary Care Diabetes Europe. Published by Elsevier Ltd. All rights reserved.
Hoxha, Teuta; Xhelili, Luan; Azemi, Mehmedali; Avdiu, Muharrem; Ismaili-Jaha, Vlora; Efendija-Beqa, Urata; Grajcevci-Uka, Violeta
2015-02-01
Acute evaluation and treatment of children presenting with dehydration represent one of the most common situation in the pediatric emergency department. To identify dehydration in infants and children before treatment, a number of symptoms and clinical signs have been evaluated. The aim of the study was to describe the performance of clinical signs in detecting dehydration in children. Two hundred children aged 1 month to 5 year were involved in our prospective study. The clinical assessment consisted of the ten clinical signs of dehydration, including those recommended by WHO (World Health Organization), heart rate, and capillary refill time. Two hundred patients with diarrhea were enrolled in the study. The mean age was 15.62±9.03 months and 57.5% were male. Of these 121 had a fluid deficit of < 5%, 68 had a deficit of 5 to 9% and 11(5.5%) had a deficit of 10% or more. Patients classified as having no or mild, moderate, and severe dehydration were found to have the following respective gains in percent weight at the end of illness: 2.44±0.3, 6.05± 1.01 and, 10.66± 0.28, respectively. All clinical signs were found more frequently with increasing amounts of dehydration(p<0.001, One-way ANOVA). The median number of findings among subjects with no or mild dehydration (deficit <5%) was 3; among those with moderate dehydration (deficit 5% to 9%) was 6.5 and among those with severe dehydration (deficit >10%) the median was 9 (p<0.0001, Kruskal-Wallis test). Using stepwise linear regression and a p value of <0.05 for entry into the model, a four-variable model including sunken eyes, skin elasticity, week radial pulse, and general appearance was derived. None of the 10 findings studied, is sufficiently accurate to be used in isolation. When considered together, sunken eyes, decreased skin turgor, weak pulse and general appearance provide the best explanatory power of the physical signs considered.
Urbánek, Marek; Pospísilová, Marie; Polásek, Miroslav
2002-04-01
The combination of capillary isotachophoresis (ITP) and capillary zone electrophoresis (CZE) in the column coupling configuration was optimized in a mode where the electrolyte for the CZE step is different from the leading and terminating ITP electrolytes. Two colored markers, picric acid and 1-nitroso-2-naphthol, were used for exact timing of the transfer of isotachophoretically stacked analyte zones into the CZE column and for the control of the residual amount of the leading and terminating ITP electrolytes entering the CZE capillary together with the analytes, thus controlling the duration of transient ITP migration in the CZE capillary and ensuring good separation of the analytes and reproducibility of the migration times (relative standard deviations 1%). ITP-CZE was applied to the simultaneous assay of several cinnamic acid derivatives and flavonoids in methanolic extracts of Sambucus flowers and Crataegus leaves and flowers. The preconcentrating and cleansing effect of the ITP step allowed injection of relatively large sample volumes (30 microL). The limits of detection were approximately 20-50 ng x mL(-1) and 100 ng x mL(-1) for the acids and flavonoids, respectively ( thick similar 200-times lower compared to conventional CE) with spectrophotometric detection at 254 nm. The ITP-CZE exhibited satisfactory linearity and precision when using CZE buffer of pseudo "pH" 9.0; 1-nitroso-2-naphthol was employed as the internal standard. The separation took approximately 35 min. The ITP-CZE results for rutin, hyperoside, and vitexin-2-O"-rhamnoside were in good accordance with those obtained previously by high-performance liquid chromatography.
Kaae, Susanne; Traulsen, Janine M; Nørgaard, Lotte S
2014-12-01
Despite pharmacists' extensive knowledge in the optimization of patients' medical treatments, community pharmacies are still fighting to earn patients' trust with respect to medicinal counselling at the counter. The aim was to investigate how patients perceive pharmacy counselling at the present time, in order to develop the patient-pharmacy relationship for the benefit of both patients and pharmacies. Short semi-structured interviews were carried out with pharmacy customers by pharmacy internship students. One hundred and eight customers in 35 independent pharmacies across Denmark were interviewed during the spring of 2011. Customers were interviewed about their expectations of pharmacies in general and their experiences with medical counselling in particular. Customers perceive community pharmacies very differently in terms of both expectations of and positive experiences with counselling. They appear to be in favour of pharmacy counselling with respect to over-the-counter medicine and first-time prescription medicine in contrast to refills. Customers find it difficult to express the health-care role of pharmacies even when experiencing and appreciating it. Lack of appreciation of pharmacy counselling for refill prescription medicine and the difficulty in defining the role of pharmacies might stem from the difficulties that customers have in understanding medicine and thus the role of counselling services with respect to medicine. The pharmacy staff does not seem to realize these barriers. For pharmacies to encourage customer interest in pharmacy counselling, the staff should start taking the identified barriers into account when planning communication strategies. © 2012 John Wiley & Sons Ltd.
Darvall, K A L; Sam, R C; Bate, G R; Adam, D J; Silverman, S H; Bradbury, A W
2010-08-01
Digital photoplethysmography (PPG) provides an inexpensive, reproducible, quantitative, non-invasive assessment of lower limb venous function. To examine the relationship between venous refilling time (VRT) and severity of venous disease, and also between changes in VRT and symptomatic improvement after ultrasound guided foam sclerotherapy (UGFS) for symptomatic superficial venous reflux (SVR). Prior to and 6 months after UGFS, 246 patients (317 limbs) completed a symptom questionnaire, underwent duplex ultrasonography and clinical assessment, and VRT measurement by digital PPG. Health related quality of life (HRQL) questionnaires were also completed. Median VRT improved from 11 to 31 s (P < 0.0005, Wilcoxon Signed Ranks). Abnormal VRT (<20 s) correlated well with the presence of SVR on duplex (sensitivity 75%, specificity 94%). Pre-treatment there was a significant relationship between reducing VRT and increasing CEAP clinical grade (P < 0.0005, chi(2)), extent of SVR on duplex (P < 0.0005) and a non-significant relationship with overall increasing symptom severity (P = 0.097). Relief of all symptoms was more likely when there was normalisation of VRT after treatment (80% vs. 65%, P < 0.0005, chi(2)). Pre-treatment VRT correlated with both generic physical (r = 0.428, P = 0.002) and disease-specific (r = -0.413, P = 0.003, Spearman's rank) HRQL. UGFS for SVR improves VRT measured by digital PPG and that improvement correlates with symptom relief. Copyright (c) 2010 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Synthetic Capillaries to Control Microscopic Blood Flow
NASA Astrophysics Data System (ADS)
Sarveswaran, K.; Kurz, V.; Dong, Z.; Tanaka, T.; Penny, S.; Timp, G.
2016-02-01
Capillaries pervade human physiology. The mean intercapillary distance is only about 100 μm in human tissue, which indicates the extent of nutrient diffusion. In engineered tissue the lack of capillaries, along with the associated perfusion, is problematic because it leads to hypoxic stress and necrosis. However, a capillary is not easy to engineer due to its complex cytoarchitecture. Here, it is shown that it is possible to create in vitro, in about 30 min, a tubular microenvironment with an elastic modulus and porosity consistent with human tissue that functionally mimicks a bona fide capillary using “live cell lithography”(LCL) to control the type and position of cells on a composite hydrogel scaffold. Furthermore, it is established that these constructs support the forces associated with blood flow, and produce nutrient gradients similar to those measured in vivo. With LCL, capillaries can be constructed with single cell precision—no other method for tissue engineering offers such precision. Since the time required for assembly scales with the number of cells, this method is likely to be adapted first to create minimal functional units of human tissue that constitute organs, consisting of a heterogeneous population of 100-1000 cells, organized hierarchically to express a predictable function.
Synthetic Capillaries to Control Microscopic Blood Flow.
Sarveswaran, K; Kurz, V; Dong, Z; Tanaka, T; Penny, S; Timp, G
2016-02-24
Capillaries pervade human physiology. The mean intercapillary distance is only about 100 μm in human tissue, which indicates the extent of nutrient diffusion. In engineered tissue the lack of capillaries, along with the associated perfusion, is problematic because it leads to hypoxic stress and necrosis. However, a capillary is not easy to engineer due to its complex cytoarchitecture. Here, it is shown that it is possible to create in vitro, in about 30 min, a tubular microenvironment with an elastic modulus and porosity consistent with human tissue that functionally mimicks a bona fide capillary using "live cell lithography"(LCL) to control the type and position of cells on a composite hydrogel scaffold. Furthermore, it is established that these constructs support the forces associated with blood flow, and produce nutrient gradients similar to those measured in vivo. With LCL, capillaries can be constructed with single cell precision-no other method for tissue engineering offers such precision. Since the time required for assembly scales with the number of cells, this method is likely to be adapted first to create minimal functional units of human tissue that constitute organs, consisting of a heterogeneous population of 100-1000 cells, organized hierarchically to express a predictable function.
Micro-injector for capillary electrophoresis.
Sáiz, Jorge; Koenka, Israel Joel; García-Ruiz, Carmen; Müller, Beat; Chwalek, Thomas; Hauser, Peter C
2015-08-01
A novel micro-injector for capillary electrophoresis for the handling of samples with volumes down to as little as 300 nL was designed and built in our laboratory for analyses in which the available volume is a limitation. The sample is placed into a small cavity located directly in front of the separation capillary, and the injection is then carried out automatically by controlled pressurization of the chamber with compressed air. The system also allows automated flushing of the injection chamber as well as of the capillary. In a trial with a capillary electrophoresis system with contactless conductivity detector, employing a capillary of 25 μm diameter, the results showed good stability of migration times and peak areas. To illustrate the technique, the fast separation of five inorganic cations (Na(+) , K(+) , NH4 (+) , Ca(2+) , and Mg(2+) ) was set up. This could be achieved in less than 3 min, with good limits of detection (10 μM) and linear ranges (between about 10 and 1000 μM). The system was demonstrated for the determination of the inorganic cations in porewater samples of a lake sediment core. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Liu, Rongrong; Spicer, Graham; Chen, Siyu; Zhang, Hao F.; Yi, Ji; Backman, Vadim
2017-02-01
Oxygen saturation (sO2) of RBCs in capillaries can indirectly assess local tissue oxygenation and metabolic function. For example, the altered retinal oxygenation in diabetic retinopathy and local hypoxia during tumor development in cancer are reflected by abnormal sO2 of local capillary networks. However, it is far from clear whether accurate label-free optical oximetry (i.e. measuring hemoglobin sO2) is feasible from dispersed red blood cells (RBCs) at the single-capillary level. The sO2-dependent hemoglobin absorption contrast present in optical scattering signal is complicated by geometry-dependent scattering from RBCs. Here we provide a theoretical model to calculate the backscattering spectra of single RBCs based on the first-order Born approximation, considering the orientation, size variation, and deformation of RBCs. We show that the oscillatory spectral behavior of RBC geometries is smoothed by variations in cell size and orientation, resulting in clear sO2-dependent spectral contrast. In addition, this spectral contrast persists with different deformations of RBCs, allowing the sO2 of individual RBCs in capillaries to be characterized. The theoretical model is verified by Mie theory and experiments using visible light optical coherence tomography (vis-OCT). Thus, this study shows for the first time the feasibility of, and provides a theoretical model for, label-free optical oximetry at the single-capillary level by backscattering-based imaging modalities, challenging the popular view that such measurements are impossible at the single-capillary level. This is promising for in vivo backscattering-based optical oximetry at the single-capillary level, to measure local capillary sO2 for early diagnosis, progression monitoring, and treatment evaluation of diabetic retinopathy and cancer.
Ryvolová, Markéta; Preisler, Jan; Foret, Frantisek; Hauser, Peter C; Krásenský, Pavel; Paull, Brett; Macka, Mirek
2010-01-01
This work for the first time combines three on-capillary detection methods, namely, capacitively coupled contactless conductometric (C(4)D), photometric (PD), and fluorimetric (FD), in a single (identical) point of detection cell, allowing concurrent measurements at a single point of detection for use in capillary electrophoresis, capillary electrochromatography, and capillary/nanoliquid chromatography. The novel design is based on a standard 6.3 mm i.d. fiber-optic SMA adapter with a drilled opening for the separation capillary to go through, to which two concentrically positioned C(4)D detection electrodes with a detection gap of 7 mm were added on each side acting simultaneously as capillary guides. The optical fibers in the SMA adapter were used for the photometric signal (absorbance), and another optical fiber at a 45 degrees angle to the capillary was applied to collect the emitted light for FD. Light emitting diodes (255 and 470 nm) were used as light sources for the PD and FD detection modes. LOD values were determined under flow-injection conditions to exclude any stacking effects: For the 470 nm LED limits of detection (LODs) for FD and PD were for fluorescein (1 x 10(-8) mol/L) and tartrazine (6 x 10(-6) mol/L), respectively, and the LOD for the C(4)D was for magnesium chloride (5 x 10(-7) mol/L). The advantage of the three different detection signals in a single point is demonstrated in capillary electrophoresis using model mixtures and samples including a mixture of fluorescent and nonfluorescent dyes and common ions, underivatized amino acids, and a fluorescently labeled digest of bovine serum albumin.
NASA Technical Reports Server (NTRS)
1988-01-01
When Programmable Implantable Medication System (PIMS) is implanted in human body, it delivers precise programmed amounts of insulin over long periods of time. Mini-Med Technologies has been refining the Technologies since initial development at APL. The size of a hockey puck, and encased in titanium shell, PIMS holds about 2 1/2 teaspoons of insulin at a programmed basal rate. If a change in measured blood sugar level dictates a different dose, the patient can vary the amount of insulin delivered by holding a small radio transceiver over the implanted system and dialing in a specific program held in the PIMS computer memory. Insulin refills are accomplished approximately 4 times a year by hypodermic needle.
Temperature-Modulated Array High-Performance Liquid Chromatography
Premstaller, Andreas; Xiao, Wenzhong; Oberacher, Herbert; O'Keefe, Matthew; Stern, David; Willis, Thomas; Huber, Christian G.; Oefner, Peter J.
2001-01-01
Using novel monolithic poly(styrene-divinylbenzene) capillary columns with an internal diameter of 0.2 mm, we demonstrate for the first time the feasibility of constructing high-performance liquid chromatography arrays for the detection of mutations by heteroduplex analysis under partially denaturing conditions. In one embodiment, such an array can be used to analyze one sample simultaneously at different temperatures to maximize the detection of mutations in DNA fragments containing multiple discrete melting domains. Alternatively, one may inject different samples onto columns kept at the same effective temperature. Further improvements in throughput can be obtained by means of laser-induced fluorescence detection and the differential labeling of samples with up to four different fluorophores. Major advantages of monolithic capillary high-performance liquid chromatographic arrays over their capillary electrophoretic analogs are the chemical inertness of the poly(styrene-divinylbenzene) stationary phase, the physical robustness of the column bed due to its covalent linkage to the inner surface of the fused silica capillary, and the feasibility to modify the stationary phase thereby allowing the separation of compounds not only on the principle of size exclusion, but also adsorption, distribution, and ion exchange. Analyses times are on the order of a few minutes and turnaround time is extremely short as there is no need for the replenishment of the separation matrix between runs. PMID:11691859
Continuous glucose monitoring in acute coronary syndrome.
Rodríguez-Quintanilla, Karina Alejandra; Lavalle-González, Fernando Javier; Mancillas-Adame, Leonardo Guadalupe; Zapata-Garrido, Alfonso Javier; Villarreal-Pérez, Jesús Zacarías; Tamez-Pérez, Héctor Eloy
2013-01-01
Diabetes mellitus is an independent risk factor for cardiovascular disease. To compare the efficacy of devices for continuous glucose monitoring and capillary glucose monitoring in hospitalized patients with acute coronary syndrome using the following parameters: time to achieve normoglycemia, period of time in normoglycemia, and episodes of hypoglycemia. We performed a pilot, non-randomized, unblinded clinical trial that included 16 patients with acute coronary artery syndrome, a capillary or venous blood glucose ≥ 140 mg/dl, and treatment with a continuous infusion of fast acting human insulin. These patients were randomized into 2 groups: a conventional group, in which capillary measurement and recording as well as insulin adjustment were made every 4h, and an intervention group, in which measurement and recording as well as insulin adjustment were made every hour with a subcutaneous continuous monitoring system. Student's t-test was applied for mean differences and the X(2) test for qualitative variables. We observed a statistically significant difference in the mean time for achieving normoglycemia, favoring the conventional group with a P = 0.02. Continuous monitoring systems are as useful as capillary monitoring for achieving normoglycemia. Copyright © 2012 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.
Tak, Vijay; Kabra, Ankur; Pardasani, Deepak; Goud, D Raghavender; Jain, Rajeev; Dubey, D K
2015-12-24
In this work, a glass capillary based microfluidic electromembrane extraction (μ-EME) was demonstrated for the first time. The device was made by connecting an auxillary borosilicate glass tubing (O.D. 3mm, I.D. 2mm) perpendicular to main borosilicate glass capillary just below one end of the capillary (O.D. 8mm, I.D. 1.2mm). It generated the distorted T-shaped device with inlet '1' and inlet '2' for the introduction of sample and acceptor solutions, respectively. At one end of this device (inlet '2'), a microsyringe containing acceptor solution along with hollow fiber (O.D. 1000μm) was introduced. This configuration creates the micro-channel between inner wall of glass capillary and outer surface of hollow fiber. Sample solution was pumped into the system through another end of glass capillary (inlet '1'), with a micro-syringe pump. The sample was in direct contact with the supported liquid membrane (SLM), consisted of 20% (w/w) di-(2-ethylhexyl)phosphate in 2-nitrophenyl octyl ether immobilized in the pores of the hollow fiber. In the lumen of the hollow fiber, the acceptor phase was present. The driving force for extraction was direct current (DC) electrical potential sustained over the SLM. Highly polar (logP=-2.5 to 1.4) basic degradation products of nitrogen mustard and VX were selected as model analytes. The influence of chemical composition of SLM, extraction time, voltage and pH of donor and acceptor phase were investigated. The model analytes were extracted from 10μL of pure water with recoveries ranging from 15.7 to 99.7% just after 3min of operation time. Under optimized conditions, good limits of detection (2-50ngmL(-1)), linearity (from 5-1000 to 100-1000ngmL(-1)), and repeatability (RSDs below 11.9%, n=3) were achieved. Applicability of the proposed μ-EME was proved by recovering triethanolamine (31.3%) from 10μL of five times diluted original water sample provided by the Organization for the Prohibition of Chemical Weapons during 28th official proficiency test. Copyright © 2015 Elsevier B.V. All rights reserved.
Ring cavity for a Raman capillary waveguide amplifier
Kurnit, N.A.
1981-01-27
A regenerative ring amplifier and regenerative ring oscillator are described which function to feed back a portion of the Stokes signal to complete the ring cavity. The ring cavity configuration allows the CO/sub 2/ laser pump signal and Stokes signal to copropagate through the Raman capillary waveguide amplifier. A Raman capillary waveguide amplifier is also provided in the return leg of the ring cavity to increase gain without increasing the round trip time. Additionally, the ring cavity can be designed such that the amplified Stokes signal is synchronous with the mode-locked spikes of the incoming CO/sub 2/ laser pump signal.
Ring cavity for a Raman capillary waveguide amplifir
Kurnit, N.A.
1981-01-27
A regenerative ring amplifier and regenerative ring oscillator are described which function to feed back a portion of the Stokes signal to complete the ring cavity. The ring cavity configuration allows the CO/sub 2/ laser pump signal and Stokes signal to copropagate through the Raman capillary waveguide amplifier. A Raman capillary waveguide amplifier is also provided in the return leg of the ring cavity to increase gain without increasing the round trip time. Additionally, the ring cavity can be designed such that the amplified Stokes signal is synchronous with the mode-locked spikes of the incoming CO/sub 2/ laser pump signal.
Ring cavity for a raman capillary waveguide amplifier
Kurnit, Norman A.
1983-07-19
A regenerative ring amplifier and regenerative ring oscillator which function to feed back a portion of the Stokes signal to complete the ring cavity. The ring cavity configuration allows the CO.sub.2 laser pump signal and Stokes signal to copropagate through the Raman capillary waveguide amplifier. A Raman capillary waveguide amplifier is also provided in the return leg of the ring cavity to increase gain without increasing the round trip time. Additionally, the ring cavity can be designed such that the amplifier Stokes signal is synchronous with the mode-locked spikes of the incoming CO.sub.2 laser pump signal.
Pediatric Sepsis Secondary to an Occult Dental Abscess: A Case Report.
Holmberg, Peter; Hellmich, Thomas; Homme, James
2017-05-01
In general, hematogenous spread of bacteria in children is uncommon. Bacteremia, however, is a known complication of dental procedures and severe caries, but is infrequently associated with primary, asymptomatic, non-procedural-related, dentoalveolar infection. The patient is a 7-year-old previously healthy boy who presented to the Emergency Department (ED) with "fever, mottling, and shaking chills." In the ED, he appeared systemically ill with fever, mottling, delayed capillary refill, and rigors. Physical examination by three different physicians failed to reveal any focus of infection. Laboratory evaluation, including blood cultures, was obtained. The patient later developed unilateral facial swelling and pain, and a dentoalveolar abscess was found. He was started on antibiotics, underwent pulpectomy and eventually, extraction, prior to improvement in symptoms. Blood cultures grew two separate anaerobic bacteria (Veillonella and Lactobacillus). This is, to our knowledge, one of the first reported cases of pediatric sepsis with two different anaerobic organisms secondary to occult dentoalveolar abscess in a pediatric patient. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: It is imperative for emergency physicians to recognize the possibility of pediatric sepsis in the setting of acute maxillary or mandibular pain, as well as in patients for whom no clear focus of infection can be found. This is particularly important for those who appear ill at presentation or meet systemic inflammatory response syndrome criteria and would benefit from further laboratory evaluation, including blood cultures, and possibly antibiotic therapy. Copyright © 2017 Elsevier Inc. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Conventional immunoblot assays have been a very useful tool for specific protein identification in the past several decades, but are tedious, labor-intensive and time-consuming. An automated capillary electrophoresis-based immunoblot assay called "Simple Western" has recently been developed that en...
Miniaturized flow injection analysis system
Folta, James A.
1997-01-01
A chemical analysis technique known as flow injection analysis, wherein small quantities of chemical reagents and sample are intermixed and reacted within a capillary flow system and the reaction products are detected optically, electrochemically, or by other means. A highly miniaturized version of a flow injection analysis system has been fabricated utilizing microfabrication techniques common to the microelectronics industry. The microflow system uses flow capillaries formed by etching microchannels in a silicon or glass wafer followed by bonding to another wafer, commercially available microvalves bonded directly to the microflow channels, and an optical absorption detector cell formed near the capillary outlet, with light being both delivered and collected with fiber optics. The microflow system is designed mainly for analysis of liquids and currently measures 38.times.25.times.3 mm, but can be designed for gas analysis and be substantially smaller in construction.
Crossover from capillary fingering to viscous fingering in a rough fracture
NASA Astrophysics Data System (ADS)
Hu, R.; Chen, Y.; Wu, D. S.
2017-12-01
Controlled by the competition between capillary and viscous forces, the displacement patterns of one fluid displacing another more viscous one exhibit capillary fingering, viscous fingering, and the crossover between the two. Although extensive studies have investigated viscous and capillary fingerings in porous and fractured media, a few studies focused on the crossover in rough fractures, and how viscous and capillary forces affect the crossover remains unclear. Using a transparent fracture visualization system, we studied how the competition impacts the crossover in a horizontal rough fracture. Drainage experiments of water displacing oil were conducted at seven flow rates (capillary number log10Ca ranging from -7.07 to -3.07) and four viscosity ratios (M = 1/1000, 1/500, 1/100 and 1/50). We consistently observed lower invading fluid saturations in the crossover zone. In addition, we proposed a phase diagram for the displacement patterns in a rough fracture that is consistent with similar studies in porous media. Based on real-time imaging and statistical analysis of the invasion morphology, we showed that the competition between the capillary and viscous forces is responsible for the saturation reduction in the crossover zone. In this zone, finger propagation toward the outlet (characteristic of viscous fingering) as well as void-filling in the transverse and backward directions (characteristic of capillary fingering), are both suppressed. Therefore, the invading fluid tends to occupy larger apertures with higher characteristic front velocity, promoting void-filling toward the outlet with thinner finger growth and resulting in a larger volume of defending fluid left behind.
Use of gold nanoparticles to detect water uptake in vascular plants.
Hwang, Bae Geun; Ahn, Sungsook; Lee, Sang Joon
2014-01-01
Direct visualization of water-conducting pathways and sap flows in xylem vessels is important for understanding the physiology of vascular plants and their sap ascent. Gold nanoparticles (AuNPs) combined with synchrotron X-ray imaging technique is a new promising tool for investigating plant hydraulics in opaque xylem vessels of vascular plants. However, in practical applications of AuNPs for real-time quantitative visualization of sap flows, their interaction with a vascular network needs to be verified in advance. In this study, the effect of AuNPs on the water-refilling function of xylem vessels is experimentally investigated with three monocot species. Discrepancy in the water uptakes starts to appear at about 20 min to 40 min after the supply of AuNP solution to the test plant by the possible gradual accumulation of AuNPs on the internal structures of vasculature. However conclusively, it is observed that the water-refilling speeds in individual xylem vessels are virtually unaffected by hydrophilically surface-modified AuNPs (diameter ∼20 nm). Therefore, the AuNPs can be effectively used as flow tracers in the xylem vessels in the first 20∼30 min without any physiological barrier. As a result, AuNPs are found to be useful for visualizing various fluid dynamic phenomena occurring in vascular plants.
Buckley, Thomas N; Turnbull, Tarryn L; Pfautsch, Sebastian; Adams, Mark A
2011-01-01
We measured sap flux (S) and environmental variables in four monospecific stands of alpine ash (Eucalyptus delegatensis R. Baker, AA) and snowgum (E. pauciflora Sieb. ex Spreng., SG) in Australia's Victorian Alps. Nocturnal S was 11.8 ± 0.8% of diel totals. We separated transpiration (E) and refilling components of S using a novel modeling approach based on refilling time constants. The nocturnal fraction of diel water loss (fn) averaged 8.6 ± 0.6% for AA and 9.8 ± 1.7% for SG; fn differed among sites but not species. Evaporative demand (D) was the strongest driver of nocturnal E (En). The ratio En/D (Gn) was positively correlated to soil moisture in most cases, whereas correlations between wind speed and Gn varied widely in sign and strength. Our results suggest (1) the large, mature trees at our subalpine sites have greater fn than the few Australian native tree species that have been studied at lower elevations, (2) AA and SG exhibit similar fn despite very different size and life history, and (3) fn may differ substantially among sites, so future work should be replicated across differing sites. Our novel approach to quantifying fn can be applied to S measurements obtained by any method. PMID:22393512
Access to Care in the Wake of Hurricane Sandy, New Jersey, 2012.
Davidow, Amy L; Thomas, Pauline; Kim, Soyeon; Passannante, Marian; Tsai, Stella; Tan, Christina
2016-06-01
Evacuation and damage following a widespread natural disaster may affect short-term access to medical care. We estimated medical care needs in New Jersey following Hurricane Sandy in 2012. Hurricane Sandy-related questions regarding medical needs included in the Behavioral Risk Factor Surveillance System survey were administered to survey respondents living in New Jersey when Sandy occurred. Recently arrived foreign-born residents were more likely than US-born residents to need medical care following Sandy. Others with greater medical needs included the uninsured and evacuees. Persons who evacuated or lived in areas that experienced the greatest hurricane impact were less likely to be able to fill a prescription. Only 15% of New Jerseyans were aware of the Emergency Pharmaceutical Assistance Program (EPAP), a federal program which allows prescription refills for the uninsured following a disaster. Recently arrived foreign-born residents and the uninsured were less frequently aware of EPAP: 8.7% and 10.9%. Populations with impaired access to care in normal times-such as the recently arrived foreign-born and the uninsured-were also at risk of compromised access in the hurricane's aftermath. Measures to address prescription refills during a disaster need better promotion among at-risk populations. (Disaster Med Public Health Preparedness. 2016;10:485-491).
Sol-gel chemistry-based Ucon-coated columns for capillary electrophoresis.
Hayes, J D; Malik, A
1997-07-18
A sol-gel chemistry-based novel approach for the preparation of a Ucon-coated fused-silica capillary column in capillary electrophoresis is presented. In this approach the sol-gel process is carried out inside 25 microm I.D. fused-silica capillaries. The sol solution contained appropriate quantities of an alkoxide-based sol-gel precursor, a polymeric coating material (Ucon), a crosslinking reagent, a surface derivatizing reagent, controlled amounts of water and a catalyst dissolved in a suitable solvent system. The coating procedure involves filling a capillary with the sol solution and allowing the sol-gel process to proceed for an optimum period. Hydrolysis of the alkoxide precursor and polycondensation of the hydrolyzed products with the surface silanol groups and the hydroxy-terminated Ucon molecules lead to the formation of a surface-bonded sol-gel coating on the inner walls of the capillary. The thickness of the coated film can be controlled by varying the reaction time, coating solution composition and experimental conditions. Commercial availability of high purity sol-gel precursors (e.g., TEOS 99.999%), the ease of coating, run-to-run and column-to-column reproducibility, and long column lifetimes make sol-gel coating chemistry very much suitable for being applied in analytical microseparations column technology. Test samples of basic proteins and nucleotides were used to evaluate the column performance. These results show that the sol-gel coating scheme has allowed for the generation of bio-compatible surfaces characterized by high separation efficiencies in CE. For different types of solutes, the sol-gel coated Ucon column consistently provided migration time R.S.D. values of the order of 0.5%.
Studies on equatorial shock formation during plasmaspheric refilling
NASA Technical Reports Server (NTRS)
Singh, N.
1994-01-01
Investigations based on small-scale simulations of microprocesses occurring when a magnetic flux tube refills with a cold plasma are summarized. Results of these investigations are reported in the following attached papers: (1) 'Numerical Simulation of Filling a Magnetic Flux Tube with a Cold Plasma: The Role of Ion Beam-Driven Instabilities'; and (2) 'Numerical Simulation of Filling a Magnetic Flux Tube with a Cold Plasma: Effects of Magnetically Trapped Hot Plasma'. Other papers included are: 'Interaction of Field-Aligned Cold Plasma Flows with an Equatorially-Trapped Hot Plasma: Electrostatic Shock Formation'; and 'Comparison of Hydrodynamic and Semikinetic Treatments for a Plasma Flow along Closed Field Lines'. A proposal for further research is included.
A continuous-flow capillary mixing method to monitor reactions on the microsecond time scale.
Shastry, M C; Luck, S D; Roder, H
1998-01-01
A continuous-flow capillary mixing apparatus, based on the original design of Regenfuss et al. (Regenfuss, P., R. M. Clegg, M. J. Fulwyler, F. J. Barrantes, and T. M. Jovin. 1985. Rev. Sci. Instrum. 56:283-290), has been developed with significant advances in mixer design, detection method and data analysis. To overcome the problems associated with the free-flowing jet used for observation in the original design (instability, optical artifacts due to scattering, poor definition of the geometry), the solution emerging from the capillary is injected directly into a flow-cell joined to the tip of the outer capillary via a ground-glass joint. The reaction kinetics are followed by measuring fluorescence versus distance downstream from the mixer, using an Hg(Xe) arc lamp for excitation and a digital camera with a UV-sensitized CCD detector for detection. Test reactions involving fluorescent dyes indicate that mixing is completed within 15 micros of its initiation and that the dead time of the measurement is 45 +/- 5 micros, which represents a >30-fold improvement in time resolution over conventional stopped-flow instruments. The high sensitivity and linearity of the CCD camera have been instrumental in obtaining artifact-free kinetic data over the time window from approximately 45 micros to a few milliseconds with signal-to-noise levels comparable to those of conventional methods. The scope of the method is discussed and illustrated with an example of a protein folding reaction. PMID:9591695
Trudeau, Kimberlee J; Hildebrand, Cristina; Garg, Priyanka; Chiauzzi, Emil; Zacharoff, Kevin L
2017-04-01
To improve pain management practices, we developed an online interactive continuing education (CE) program for primary care providers (PCPs). This program follows the flow of clinical decision-making through simulated cases at critical pain treatment points along the pain treatment continuum. A randomized controlled trial was conducted to test the efficacy of this program. Participants were randomized to either the experimental condition or the control condition (online, text-based CE program). A total of 238 primary care providers were recruited through hospitals, professional newsletters, and pain conferences. Participants in both conditions reported significantly improved scores on knowledge (KNOW-PAIN 50), attitudes (CAOS), and pain practice behaviors (PPBS) scales over the four-month study. The experimental condition showed significantly greater change over time on the tamper-resistant formulations (TRFs) of opioids and dosing CAOS subscale compared with the control condition. Post hoc comparisons suggested that participants in the experimental condition were less likely to endorse use of opioid TRFs over time compared with the control condition. Exploratory analyses for potential moderators indicated a significant three-way interaction with time, condition, and discipline (i.e., physician vs other) for the impediments and concerns attitudes subscale and the early refill behaviors subscale. Post hoc comparisons indicated that physicians in the experimental condition exhibited the greatest change in attitudes and the nonphysicians exhibited the greatest change in reported behaviors in response to requests for early refills. Findings suggest online CE programs may positively impact PCPs' knowledge, attitudes, and pain practice behaviors but provide minimal evidence for the value of including interactivity. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Gharbharan, Deepa; Britsch, Denae; Soto, Gabriela; Weed, Anna-Marie Karen; Svec, Frantisek; Zajickova, Zuzana
2015-08-21
Tuning of preparation conditions, such as variations in the amount of a porogen, concentration of an aqueous acid catalyst, and adjustment in polymerization temperature and time, towards optimized chromatographic performance of thermally polymerized monolithic capillaries prepared from 3-(methacryloyloxy)propyltrimethoxysilane has been carried out. Performance of capillary columns in reversed-phase liquid chromatography was assessed utilizing various sets of solutes. Results describing hydrophobicity, steric selectivity, and extent of hydrogen bonding enabled comparison of performance of hybrid monolithic columns prepared under thermal (TSG) and photopolymerized (PSG) conditions. Reduced amounts of porogen in the polymerization mixture, and prolonged reaction times were necessary for the preparation of monolithic columns with enhanced retention and column efficiency that reached to 111,000 plates/m for alkylbenzenes with shorter alkyl chains. Both increased concentration of catalyst and higher temperature resulted in faster polymerization but inevitably in insufficient time for pore formation. Thermally polymerized monoliths produced surfaces, which were slightly more hydrophobic (a methylene selectivity of 1.28±0.002 TSG vs 1.20±0.002 PSG), with reduced number of residual silanols (a caffeine/phenol selectivity of 0.13±0.001 TSG vs 0.17±0.003 PSG). However, steric selectivity of 1.70±0.01 was the same for both types of columns. The batch-to-batch repeatability was better using thermal initiation compared to monolithic columns prepared under photopolymerized conditions. RSD for retention factor of benzene was 3.7% for TSG capillaries (n=42) vs. 6.6% for PSG capillaries (n=18). A similar trend was observed for columns prepared within the same batch. Copyright © 2015 Elsevier B.V. All rights reserved.
Mountain glaciers caught on camera
NASA Astrophysics Data System (ADS)
Balcerak, Ernie
2011-12-01
Many glaciers around the world are melting, and new research is showing some of the dramatic details. Ulyana Horodyskyj, a graduate student at the Cooperative Institute for Research in Environmental Sciences (CIRES), University of Colorado at Boulder, set up cameras to take time-lapse photographs of three lakes on a glacier in Nepal. This allowed her and her colleagues to see the supraglacial lake drain in real time for the first time, making it possible to estimate how much water was involved and how long it took for the lake to drain and refill. Horodyskyj said in a press conference at the AGU Fall Meeting that such observations of supraglacial lakes are valuable because in a warming climate, melting glaciers can lead to formation of supraglacial lakes.
Morifuji, Takeshi; Murakami, Shinichiro; Fujita, Naoto; Kondo, Hiroyo; Fujino, Hidemi
2012-01-01
The purpose of this study was to examine whether exercise training can prevent microangiopathy of skeletal muscles in rats with type 2 diabetes and if succinate dehydrogenase (SDH) activity, an indicator of mitochondrial oxidative enzyme activity, is involved in the prevention of microangiopathy. Six-week-old male Goto-Kakizaki (GK) rats and age-matched male Wistar rats (control group (Con)) were used. GK rats were randomly assigned to nonexercise (DB) and exercise (DBEx) groups. The DBEx group was trained on a treadmill 5 times a week for 3 weeks. No significant differences in the capillary-to-fibre ratio or the capillary density were observed between the 3 groups. The luminal capillary diameter of the DB group was significantly lower than that of the Con group, whereas the capillary diameter of the DBEx group was significantly higher than that of the DB group. In addition, SDH activity was significantly higher in the DBEx group than in the Con and DB groups. Microangiopathy of skeletal muscles in type 2 diabetes was correlated with a decrease in the luminal capillary diameter, which was prevented by exercise training. Thus, the mitochondrial oxidative capacity appears to be involved in the overall mechanism by which exercise prevents microangiopathy.
Wang, Xuan; Ye, Nengsheng; Hu, Xiaoyu; Liu, Qingye; Li, Jian; Peng, Lin; Ma, Xiaotong
2018-05-25
In this study, a metal-organic framework (MOF), [Mn(cam)(bpy)], was synthesized and characterized by thermogravimetric analysis, scanning electron microscopy, and Fourier transform infrared spectrometry. An open-tubular capillary column was fabricated from [Mn(cam)(bpy)] via the amide coupling method. Ten types of sulfonamides were separated through the fabricated capillary column, which showed a good limits of detection (< 0.07 μg·mL -1 ) and a linear ranges (1-100 μg·mL -1 or 5-100 μg·mL -1 ) with a high correlation coefficients (R 2 > 0.9987). The intra-day, inter-day and column-to-column relative standard deviations (RSDs) in the migration times ranged from 0.44% to 4.87%, and the peak area RSDs ranged from 0.80% to 7.28%. The developed capillary electrochromatography method can be successfully utilized for the determination of sulfonamides in tap water and milk samples. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
ssDNA degradation along capillary electrophoresis process using a Tris buffer.
Ric, Audrey; Ong-Meang, Varravaddheay; Poinsot, Verena; Martins-Froment, Nathalie; Chauvet, Fabien; Boutonnet, Audrey; Ginot, Frédéric; Ecochard, Vincent; Paquereau, Laurent; Couderc, François
2017-06-01
Tris-Acetate buffer is currently used in the selection and the characterization of ssDNA by capillary electrophoresis (CE). By applying high voltage, the migration of ionic species into the capillary generates a current that induces water electrolysis. This phenomenon is followed by the modification of the pH and the production of Tris derivatives. By injecting ten times by capillary electrophoresis ssDNA (50 nM), the whole oligonucleotide was degraded. In this paper, we will show that the Tris buffer in the running vials is modified along the electrophoretic process by electrochemical reactions. We also observed that the composition of the metal ions changes in the running buffer vials. This phenomenon, never described in CE, is important for fluorescent ssDNA analysis using Tris buffer. The oligonucleotides are degraded by electrochemically synthesized species (present in the running Tris vials) until it disappears, even if the separation buffer in the capillary is clean. To address these issues, we propose to use a sodium phosphate buffer that we demonstrate to be electrochemically inactive. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zheng, Juan; Lu, Cuiming; Huang, Junlong; Chen, Luyi; Ni, Chuyi; Xie, Xintong; Zhu, Fang; Wu, Dingcai; Ouyang, Gangfeng
2018-08-15
Novel powdery polymer aerogel (PPA) prepared via the (micro)emulsion polymerization and the following hyper crosslinking reaction was fabricated as stationary phase of capillary column for the first time. Due to its powdery morphology, unique 3D nano-network structure, high surface area and good thermostability, the PPA-coated capillary column demonstrated high-resolution chromatographic separation towards nonpolar and weakly polar organic compounds, including benzene series, n-alkanes, ketone mixtures and trichlorobenzenes. Moreover, the reproducibility, quantitative analysis ability and thermostability of PPA-coated capillary column were also evaluated. The relative standard deviations for three replicate determinations of selected analytes were 0.02-0.11%, 0.12-0.26% and 1.2-3.6% for run-to-run, day-to-day and column-to-column analyses, respectively. The PPA demonstrated good thermostability, and the PPA-coated capillary column was proved to be heat-resistant (270 °C). The results of this study show PPA is an excellent candidate to be employed as stationary phase for gas chromatography capillary. Copyright © 2018 Elsevier B.V. All rights reserved.
The role of CMEs in the refilling of Mercury's exosphere
NASA Astrophysics Data System (ADS)
Lichtenegger, H. I. M.; Lammer, H.; Kallio, E.; Mura, A.; Wurz, P.; Millio, A.; Torka, K.; Livi, S.; Barabash, S.; Orsini, S.
A better understanding of the connection between the solar plasma environment and surface particle release processes from Mercury is needed for planned exospheric and remote surface geochemical studies by the Neutral Particle Analyzer Ion Spectrometer sensors ELENA, STROFIO, MIPA and PICAM of the SERENA instrument on board of ESA's BepiColombo planetary orbiter MPO. We study the exosphere refilling of various elements caused by sputtering during the exposure of CMEs from Mercury's surface by applying a quasi-neutral hybrid model and by using a survey of potential surface analogues, which are based on laboratory studied Lunar surface regolith and hypothetical analogue materials as derived form experimental studies. The formation and refilling of Mercury's exosphere during CME exposure is compared with usual solar wind cases by considering various parameters, such as regolith porosity, binding energies and elemental fractionation of the surface minerals. For studying the influence of these parameters we use the derived geochemical surface composition and the exposed surface are as an input for a 3-D exospheric model for studying whether the measurements of exospheric particles by the particle detectors is feasible along the MPO spacecraft orbit. Finally we find a denser exosphere environment distributed over a larger planetary area during collisions of CMEs or magnetic clouds with Mercury.
NASA Astrophysics Data System (ADS)
Rahmitha, Amelia; Utami, Endang Sri; Sitohang, Marya Yenita
2018-02-01
People used refilled-drinking-water for household and food stall because its efficient and low cost. Based on Indonesian Health Ministry regulation, it should not have any coliform bacteria. This study aimed to describe the bacteriological contamination of refilled drinking water using geographical information system (GIS). In this research, it was used an analytic observational method. The samples were from all available (37) depots in Tembalang district, one form each depot took used a sterile bottle. Contamination of bacteria was identified by Most Probable Number (MPN) method lactose broth media, Mac Conkey media, and IMVIC media. The depot samples were then plotted on (GIS). This study showed 95% samples were not feasible to consume since they contamined coliform. All sub-district had one that contaminated by coliform, 75% sub-districts had depots that contaminated Escherichia coli, while 55% sub-districts had depots that contaminated with other bacteria. The internal risk factors of the contamination were the absence of hygiene-sanitation worthy certificate (95%), depots location near to pollution sources (5%), and the misused of UV light. The external risk factor was lack of quality control that was not as the sterilization from office health Semarang city. Policy reinforcement should be done to all of the depots.
Dastgir, Amer; Ranalli, Nathan J; MacGregor, Theresa L; Aldana, Philipp R
2015-09-01
The authors report an unusual case of intrathecal baclofen withdrawal due to the perforation and subsequent leakage of a baclofen pump catheter in a patient with spastic cerebral palsy. A 15-year-old boy underwent an uncomplicated placement of an intrathecal baclofen pump for the treatment of spasticity due to cerebral palsy. After excellent control of symptoms for 3 years, the patient presented to the emergency department with increasing tremors following a refill of his baclofen pump. Initial evaluation consisted of radiographs of the pump and catheter, which appeared normal, and a successful aspiration of CSF from the pump's side port. A CT dye study revealed a portion of the catheter directly overlying the refill port and extravasation of radiopaque dye into the subfascial pocket anterior to the pump. During subsequent revision surgery, a small puncture hole in the catheter was seen to be leaking the drug. The likely cause of the puncture was an inadvertent perforation of the catheter by a needle during the refilling of the pump. This case report highlights a unique complication in a patient with an intrathecal baclofen pump. Physicians caring for these patients should be aware of this rare yet potential complication in patients presenting with baclofen withdrawal symptoms.
Understanding health care communication preferences of veteran primary care users.
LaVela, Sherri L; Schectman, Gordon; Gering, Jeffrey; Locatelli, Sara M; Gawron, Andrew; Weaver, Frances M
2012-09-01
To assess veterans' health communication preferences (in-person, telephone, or electronic) for primary care needs and the impact of computer use on preferences. Structured patient interviews (n=448). Bivariate analyses examined preferences for primary care by 'infrequent' vs. 'regular' computer users. Only 54% were regular computer users, nearly all of whom had ever used the internet. 'Telephone' was preferred for 6 of 10 reasons (general medical questions, medication questions and refills, preventive care reminders, scheduling, and test results); although telephone was preferred by markedly fewer regular computer users. 'In-person' was preferred for new/ongoing conditions/symptoms, treatment instructions, and next care steps; these preferences were unaffected by computer use frequency. Among regular computer users, 1/3 preferred 'electronic' for preventive reminders (37%), test results (34%), and refills (32%). For most primary care needs, telephone communication was preferred, although by a greater proportion of infrequent vs. regular computer users. In-person communication was preferred for reasons that may require an exam or visual instructions. About 1/3 of regular computer users prefer electronic communication for routine needs, e.g., preventive reminders, test results, and refills. These findings can be used to plan patient-centered care that is aligned with veterans' preferred health communication methods. Published by Elsevier Ireland Ltd.
Rink, Cameron; Gnyawali, Surya; Stewart, Richard; Teplitsky, Seth; Harris, Hallie; Roy, Sashwati; Sen, Chandan K.; Khanna, Savita
2017-01-01
Ischemic stroke results in excessive release of glutamate, which contributes to neuronal cell death. Here, we test the hypothesis that otherwise neurotoxic glutamate can be productively metabolized by glutamate oxaloacetate transaminase (GOT) to maintain cellular energetics and protect the brain from ischemic stroke injury. The GOT-dependent metabolism of glutamate was studied in primary neural cells and in stroke-affected C57-BL6 mice using magnetic resonance spectroscopy and GC-MS. Extracellular Glu sustained cell viability under hypoglycemic conditions and increased GOT-mediated metabolism in vitro. Correction of stroke-induced hypoxia using supplemental oxygen in vivo lowered Glu levels as measured by 1H magnetic resonance spectroscopy. GOT knockdown abrogated this effect and caused ATP loss in the stroke-affected brain. GOT overexpression increased anaplerotic refilling of tricarboxylic acid cycle intermediates in mouse brain during ischemic stroke. Furthermore, GOT overexpression not only reduced ischemic stroke lesion volume but also attenuated neurodegeneration and improved poststroke sensorimotor function. Taken together, our results show that GOT enables metabolism of otherwise neurotoxic extracellular Glu through a truncated tricarboxylic acid cycle under hypoglycemic conditions.—Rink, C., Gnyawali, S., Stewart, R., Teplitsky, S., Harris, H., Roy, S., Sen, C. K., Khanna, S. Glutamate oxaloacetate transaminase enables anaplerotic refilling of TCA cycle intermediates in stroke-affected brain. PMID:28096234
Suba, Dávid; Urbányi, Zoltán; Salgó, András
2016-10-01
Capillary electrophoresis techniques are widely used in the analytical biotechnology. Different electrophoretic techniques are very adequate tools to monitor size-and charge heterogenities of protein drugs. Method descriptions and development studies of capillary zone electrophoresis (CZE) have been described in literature. Most of them are performed based on the classical one-factor-at-time (OFAT) approach. In this study a very simple method development approach is described for capillary zone electrophoresis: a "two-phase-four-step" approach is introduced which allows a rapid, iterative method development process and can be a good platform for CZE method. In every step the current analytical target profile and an appropriate control strategy were established to monitor the current stage of development. A very good platform was established to investigate intact and digested protein samples. Commercially available monoclonal antibody was chosen as model protein for the method development study. The CZE method was qualificated after the development process and the results were presented. The analytical system stability was represented by the calculated RSD% value of area percentage and migration time of the selected peaks (<0.8% and <5%) during the intermediate precision investigation. Copyright © 2016 Elsevier B.V. All rights reserved.
Pugsley, Haley R.; Swearingen, Kristian E.; Dovichi, Norman J.
2009-01-01
A number of algorithms have been developed to correct for migration time drift in capillary electrophoresis. Those algorithms require identification of common components in each run. However, not all components may be present or resolved in separations of complex samples, which can confound attempts for alignment. This paper reports the use of fluorescein thiocarbamyl derivatives of amino acids as internal standards for alignment of 3-(2-furoyl)quinoline-2-carboxaldehyde (FQ)-labeled proteins in capillary sieving electrophoresis. The fluorescein thiocarbamyl derivative of aspartic acid migrates before FQ-labeled proteins and the fluorescein thiocarbamyl derivative of arginine migrates after the FQ-labeled proteins. These compounds were used as internal standards to correct for variations in migration time over a two-week period in the separation of a cellular homogenate. The experimental conditions were deliberately manipulated by varying electric field and sample preparation conditions. Three components of the homogenate were used to evaluate the alignment efficiency. Before alignment, the average relative standard deviation in migration time for these components was 13.3%. After alignment, the average relative standard deviation in migration time for these components was reduced to 0.5%. PMID:19249052
DOE Office of Scientific and Technical Information (OSTI.GOV)
Higashiguchi, Takeshi; Yugami, Noboru; CREST, Japan Science and Technology Agency, 4-1-8 Honcho, Kanagawa, Saitama 332-0012
2010-04-15
We demonstrated the production of an optical waveguide in a capillary discharge-produced plasma using a cylindrical capillary. Plasma parameters of its waveguide were characterized by use of both a Nomarski laser interferometer and a hydrogen plasma line spectrum. A space-averaged maximum temperature of 3.3 eV with electron densities of the order of 10{sup 17} cm{sup -3} was observed at a discharge time of 150 ns and a maximum discharge current of 400 A. An ultrashort, intense laser pulse was guided by use of this plasma channel.
Ring cavity for a Raman capillary waveguide amplifier
Kurnit, N.A.
1983-07-19
Disclosed is a regenerative ring amplifier and regenerative ring oscillator which function to feed back a portion of the Stokes signal to complete the ring cavity. The ring cavity configuration allows the CO[sub 2] laser pump signal and Stokes signal to copropagate through the Raman capillary waveguide amplifier. A Raman capillary waveguide amplifier is also provided in the return leg of the ring cavity to increase gain without increasing the round trip time. Additionally, the ring cavity can be designed such that the amplifier Stokes signal is synchronous with the mode-locked spikes of the incoming CO[sub 2] laser pump signal. 6 figs.
Control of electroosmosis in coated quartz capillaries
NASA Technical Reports Server (NTRS)
Herren, Blair J.; Van Alstine, James; Snyder, Robert S.; Shafer, Steven G.; Harris, J. Milton
1987-01-01
The effectiveness of various coatings for controlling the electroosmotic fluid flow that hinders electrophoretic processes is studied using analytical particle microelectrophoresis. The mobilities of 2-micron diameter glass and polystyrene latex spheres (exhibiting both negative and zero effective surface charge) were measured in 2-mm diameter quartz capillaries filled with NaCl solutions within the 3.5-7.8 pH range. It is found that capillary inner surface coatings using 5000 molecular weight (or higher) poly(ethylene glycol): significantly reduced electroosmosis within the selected pH range, were stable for long time periods, and appeared to be more effective than dextran, methylcellulose, or silane coatings.
NASA Astrophysics Data System (ADS)
Okada, Shigenori; Schraufnagel, Dean E.
2005-08-01
The mammalian tongue has evolved for specialized functions in different species. The structure of its papillae tells about the animal's diet, habit, and taxonomy. The opossum has four kinds of lingual papillae (filiform, conical, fungiform, vallate). Scanning electron microscopy of the external features, connective tissue cores, and corrosion casts of the microvasculature show the filiform papillae have a spearhead-like main process and spiny accessory processes around the apical part of the main process. The shape and number of both processes depend on their position on the tongue. On the apex, the main processes have shovel-like capillary networks and the accessory processes have small conical networks. On the lingual radix, the processes have small capillary loops. In the patch region, conical papillae have capillaries arranged as a full sail curving posteriorly. The fungiform papillae are scattered among the filiform papillae and have capillary baskets beneath each taste bud. Giant fungiform papillae on the tongue tip are three to four times larger than the ones on the lingual body. Capillaries of giant papillae form a fan-shaped network. The opossum has three vallate papillae arranged in a triangle. Their tops have secondary capillary loops but not their lateral surfaces. Mucosal folds on the posterolateral border have irregular, fingerlike projections with cylindrical capillary networks. These findings and the structure of the rest of the masticatory apparatus suggest the lingual papillae of opossum have kept their ancestral carnivorous features but also developed the herbivore characteristics of other marsupials.
Okada, Shigenori; Schraufnagel, Dean E
2005-08-01
The mammalian tongue has evolved for specialized functions in different species. The structure of its papillae tells about the animal's diet, habit, and taxonomy. The opossum has four kinds of lingual papillae (filiform, conical, fungiform, vallate). Scanning electron microscopy of the external features, connective tissue cores, and corrosion casts of the microvasculature show the filiform papillae have a spearhead-like main process and spiny accessory processes around the apical part of the main process. The shape and number of both processes depend on their position on the tongue. On the apex, the main processes have shovel-like capillary networks and the accessory processes have small conical networks. On the lingual radix, the processes have small capillary loops. In the patch region, conical papillae have capillaries arranged as a full sail curving posteriorly. The fungiform papillae are scattered among the filiform papillae and have capillary baskets beneath each taste bud. Giant fungiform papillae on the tongue tip are three to four times larger than the ones on the lingual body. Capillaries of giant papillae form a fan-shaped network. The opossum has three vallate papillae arranged in a triangle. Their tops have secondary capillary loops but not their lateral surfaces. Mucosal folds on the posterolateral border have irregular, fingerlike projections with cylindrical capillary networks. These findings and the structure of the rest of the masticatory apparatus suggest the lingual papillae of opossum have kept their ancestral carnivorous features but also developed the herbivore characteristics of other marsupials.
Capillary Electrophoresis Sensitivity Enhancement Based on Adaptive Moving Average Method.
Drevinskas, Tomas; Telksnys, Laimutis; Maruška, Audrius; Gorbatsova, Jelena; Kaljurand, Mihkel
2018-06-05
In the present work, we demonstrate a novel approach to improve the sensitivity of the "out of lab" portable capillary electrophoretic measurements. Nowadays, many signal enhancement methods are (i) underused (nonoptimal), (ii) overused (distorts the data), or (iii) inapplicable in field-portable instrumentation because of a lack of computational power. The described innovative migration velocity-adaptive moving average method uses an optimal averaging window size and can be easily implemented with a microcontroller. The contactless conductivity detection was used as a model for the development of a signal processing method and the demonstration of its impact on the sensitivity. The frequency characteristics of the recorded electropherograms and peaks were clarified. Higher electrophoretic mobility analytes exhibit higher-frequency peaks, whereas lower electrophoretic mobility analytes exhibit lower-frequency peaks. On the basis of the obtained data, a migration velocity-adaptive moving average algorithm was created, adapted, and programmed into capillary electrophoresis data-processing software. Employing the developed algorithm, each data point is processed depending on a certain migration time of the analyte. Because of the implemented migration velocity-adaptive moving average method, the signal-to-noise ratio improved up to 11 times for sampling frequency of 4.6 Hz and up to 22 times for sampling frequency of 25 Hz. This paper could potentially be used as a methodological guideline for the development of new smoothing algorithms that require adaptive conditions in capillary electrophoresis and other separation methods.
Less is more: limiting narcotic prescription quantities for common orthopedic procedures.
O'Neill, Daniel Fulham; Webb Thomas, Christopher
2014-11-01
Clinicians are now appreciating that the perception of pain is a multifaceted, biopsychosocial construct. Expectation of postsurgical pain is part of this construct and should be considered preoperatively. It is our belief that by establishing reasonable expectations with preoperative teaching, we can minimize narcotic use and lessen untoward issues that can potentially follow. With this goal in mind, we have been using a comprehensive pre- and postoperative program for our outpatient orthopedic surgery patients for the last 5 years, which includes physical, pharmacologic, and simple sport psychological techniques. We reviewed postoperative prescription narcotic purchases in 133 consecutive surgical patients during the last year (2013). All patients were given a prescription postoperatively for 10 hydrocodone 5-mg/acetaminophen 500-mg tablets, with 1 refill. We then contacted the patients' pharmacies to assess the actual amount purchased. Data were available for 100 patients. Of these, 62 patients had undergone "simple" arthroscopies and 38 had had "open" procedures, including 25 anterior cruciate ligament reconstructions, 4 tibial tubercle osteotomies, and various other surgeries. Of the 62 arthroscopies, 24 patients (39%) refilled their prescriptions, with 4 patients (6%) needing > 1 refill. Of the 38 open procedures, 16 patients (42%) refilled their medications, 2 (5%), more than once. Thus, 89% of patients required ≤ 20 narcotic tablets after undergoing common orthopedic operations. No patient needed chronic narcotic medication. Pain is a complex issue and patient expectation of postoperative pain is one aspect that can potentially affect the amount of narcotics used. By preparing the patient both physically and psychologically, we believe the amount of narcotics used postoperatively can be decreased without affecting pain control. As a result, the multiple possible detriments of having more narcotics available than actually necessary would be lessened. By limiting the overall number of narcotic tablets prescribed, decreased use by the patient when such a medication may no longer be appropriate, and minimized use by others in the household who might have access to it would decrease.
Schaffner, Donald W; Jensen, Dane; Gerba, Charles P; Shumaker, David; Arbogast, James W
2018-02-01
Concern has been raised regarding the public health risks from refillable bulk-soap dispensers because they provide an environment for potentially pathogenic bacteria to grow. This study surveyed the microbial quality of open refillable bulk soap in four different food establishment types in three states. Two hundred ninety-six samples of bulk soap were collected from food service establishments in Arizona, New Jersey, and Ohio. Samples were tested for total heterotrophic viable bacteria, Pseudomonas, coliforms and Escherichia coli, and Salmonella. Bacteria were screened for antibiotic resistance. The pH, solids content, and water activity of all soap samples were measured. Samples were assayed for the presence of the common antibacterial agents triclosan and parachlorometaxylenol. More than 85% of the soap samples tested contained no detectable microorganisms, but when a sample contained any detectable microorganisms, it was most likely contaminated at a very high level (∼7 log CFU/mL). Microorganisms detected in contaminated soap included Klebsiella oxytoca, Serratia liquefaciens, Shigella sonnei, Enterobacter gergoviae, Serratia odorifera, and Enterobacter cloacae. Twenty-three samples contained antibiotic-resistant organisms, some of which were resistant to two or more antibiotics. Every sample containing less than 4% solids had some detectable level of bacteria, whereas no samples with greater than 14% solids had detectable bacteria. This finding suggests the use of dilution and/or low-cost formulations as a cause of bacterial growth. There was a statistically significant difference ( P = 0.0035) between the fraction of bacteria-positive samples with no detected antimicrobial agent (17%) and those containing an antimicrobial agent (7%). Fast food operations and grocery stores were more likely to have detectable bacteria in bulk-soap samples compared with convenience stores ( P < 0.05). Our findings underscore the risk to public health from use of refillable bulk-soap dispensers in food service establishments.
Asche, Carl V; Zografos, Panagiotis; Norlin, Jenny M; Urbanek, Bill; Mamay, Carl; Makin, Charles; Erntoft, Sandra; Chen, Chi-Chang; Hines, Dionne M; Mark Siegel, Daniel
2016-01-01
To compare health care resource utilization and treatment patterns between patients with actinic keratosis (AK) treated with ingenol mebutate gel (IngMeb) and those treated with other field-directed AK therapies. A retrospective, propensity-score-matched, cohort study compared refill/repeat and adding-on/switching patterns and outpatient visits and prescriptions (health care resource utilization) over 6 months in patients receiving IngMeb versus those receiving imiquimod, 5-fluorouracil, diclofenac sodium, and methyl aminolevulinate or aminolevulinic acid photodynamic therapy (MAL/ALA-PDT). The final sample analyzed included four matched treatment cohort pairs (IngMeb and comparator; n = 790-971 per treatment arm). Refill rates were similar except for imiquimod (15% vs. 9% for imiquimod and IngMeb, respectively; P < 0.05). MAL/ALA-PDT treatment repetition rates were higher than IngMeb refill rates (20% vs. 10%; P < 0.05). Topical agent add-on/switch rates were comparable. PDT had higher switch rates than did IngMeb (5% vs. 2%; P < 0.05). The IngMeb cohort had a significantly lower proportion of patients with at least one AK-related outpatient visit during the 6-month follow-up than did any other cohort: versus imiquimod (50% vs. 66%; P < 0.0001), versus 5-fluorouracil (50% vs. 69%; P < 0.0001), versus diclofenac sodium (51% vs. 56%; P = 0.034), and versus MAL/ALA-PDT (50% vs. 100%; P < 0.0001). There were significantly fewer AK-related prescriptions among patients receiving IngMeb than among patients in other cohorts. Results based on the first 6 months after treatment initiation suggested that most field-directed AK therapies had clinically comparable treatment patterns except imiquimod, which was associated with higher refill rates, and PDT, which was associated with significantly more frequent treatment sessions and higher switching rates. IngMeb was also associated with significantly fewer outpatient visits than were other field-directed therapies. Copyright © 2016. Published by Elsevier Inc.
Hero, Christel; Svensson, Ann-Marie; Franzén, Stefan; Miftaraj, Mervete; Gudbjörnsdottir, Soffia; Eeg-Olofsson, Katarina; Eliasson, Björn; Andersson Sundell, Karolina
2018-01-01
Objectives To analyse the association between refill adherence to lipid-lowering medications, and the risk of cardiovascular disease (CVD) and mortality in patients with type 2 diabetes mellitus. Design Cohort study. Setting National population-based cohort of Swedish patients with type 2 diabetes mellitus. Participants 86 568 patients aged ≥18 years, registered with type 2 diabetes mellitus in the Swedish National Diabetes Register, who filled at least one prescription for lipid-lowering medication use during 2007–2010, 87% for primary prevention. Exposure and outcome measures Refill adherence of implementation was assessed using the medication possession ratio (MPR), representing the proportion of days with medications on hand during an 18-month exposure period. MPR was categorised by five levels (≤20%, 21%–40%, 41%–60%, 61%–80% and >80%). Patients without medications on hand for ≥180 days were defined as non-persistent. Risk of CVD (myocardial infarction, ischaemic heart disease, stroke and unstable angina) and mortality by level of MPR and persistence was analysed after the exposure period using Cox proportional hazards regression and Kaplan-Meier, adjusted for demographics, socioeconomic status, concurrent medications and clinical characteristics. Results The hazard ratios for CVD ranged 1.33–2.36 in primary prevention patients and 1.19–1.58 in secondary prevention patients, for those with MPR ≤80% (p<0.0001). The mortality risk was similar regardless of MPR level. The CVD risk was 74% higher in primary prevention patients and 33% higher in secondary prevention patients, for those who were non-persistent (p<0.0001). The mortality risk was 6% higher in primary prevention patients and 18% higher in secondary prevention patients, for non-persistent patients (p<0.0001). Conclusions Higher refill adherence to lipid-lowering medications was associated with lower risk of CVD in primary and secondary prevention patients with type 2 diabetes mellitus. PMID:29602853
Tale of two sites: capillary versus arterial blood glucose testing in the operating room.
Akinbami, Felix; Segal, Scott; Schnipper, Jeffrey L; Stopfkuchen-Evans, Matthias; Mills, Jonathan; Rogers, Selwyn O
2012-04-01
Pre- and intraoperative glycemic control has been identified as a putative target to improve outcomes of surgical patients. Glycemic control requires frequent monitoring of blood glucose levels with appropriate adjustments. However, monitoring standards have been called into question, especially in cases in which capillary samples are used. Point-of-care testing (POCT) using capillary samples and glucometers has been noted to give relatively accurate results for critically ill patients. However, the package inserts of most glucometers warn that they should not be used for patients in shock. This has led clinicians to doubt their accuracy in the operating room. The accuracy of capillary samples when tested in patients undergoing surgical procedures has not been proven. This study aims to determine the accuracy of intraoperative blood glucose values using capillary samples relative to arterial samples. A prospective study was conducted by collecting paired capillary and arterial samples of patients undergoing major operations at a tertiary medical center from August 2009 to May 2011. Subjects were a convenience sample of patients who had arterial lines and needed glucose testing while undergoing the procedure. Precision Xceed Pro (Abbott) handheld glucometers were used to obtain the blood glucose values. Our primary outcome of interest was the degree of correlation between capillary and arterial blood glucose values or the degree to which arterial glucose levels can be predicted by capillary glucose samples. We used linear regression and the Student t tests for statistical analyses. Seventy-two-paired samples were collected. Of the cases, 54% were major abdominal operations, whereas 24% were vascular operations. The mean values ± standard deviation for glucose levels were 146 ± 35 mg/dL (capillary) and 147 ± 36 mg/dL (arterial). The mean time ± standard deviation between the collection of both samples was 3.5 ± 1.3 minutes. The regression coefficient showed a strong positive correlation of .91 between capillary glucose values and arterial values (P < .001) although correlation was less stringent at the hyperglycemic range of values. The R(2) statistic was 84%. Differences in values between capillary and arterial samples would not have altered the diagnosis of hypo- and hyperglycemia using typical thresholds. Capillary samples collected intraoperatively are strongly correlated with arterial samples. Glucose monitoring in the operating room can be safely performed by collecting capillary samples for POCT. However, clinicians should still be cautious when interpreting glucose levels that are high, either by repeating the blood glucose test or by having samples sent to the laboratory. Copyright © 2012 Elsevier Inc. All rights reserved.
Zhang, Lan; Liu, Yuanhuan; Chen, Guonan
2004-07-23
A rapid, easy and reproducible capillary electrophoresis (CE) method for the simultaneous determination of allantoin, choline and arginine in Rhizoma Dioscoreae was developed first time. Under the optimum condition, the three analytes could be well separated within 5 min in a 70 cm (60 cm effective length) x 75 microm i.d. capillary. The relative standard deviations for both migration time and peak height were less than 3.20%. The linear response range was 5.0-150, 0.9-100 and 1.0-200 microg/ml for arginine, choline and allantoin, respectively. The detection limit of three components was 2.0, 0.4 and 0.5 microg/ml for arginine, choline and allantoin, respectively. Contents of arginine, choline and allantoin in the crude drug of Rhizoma Dioscoreae could be easily determined by the proposed method with satisfactory results.
Whitmore, Colin D.; Essaka, David; Dovichi, Norman J.
2009-01-01
An ultrasensitive laser-induced fluorescence detector was used with capillary electrophoresis for the study of 5-carboxy-tetramethylrhodamine. The raw signal from the detector provided roughly three orders of magnitude dynamic range. The signal saturated at high analyte concentrations due to the dead time associated with the single-photon counting avalanche photodiode employed in the detector. The signal can be corrected for the detector dead time, providing an additional order of magnitude dynamic range. To further increase dynamic range, two fiber-optic beam-splitters were cascaded to generate a primary signal and two attenuated signals, each monitored by a single-photon counting avalanche photodiode. The combined signals from the three photodiodes are reasonably linear from the concentration detection limit of 3 pM to 10 μM, the maximum concentration investigated, a range of 3,000,000. Mass detection limits were 150 yoctomoles injected onto the capillary. PMID:19836546
Spontaneous Imbibition in Low Permeability Medium, SUPRI TR-114
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kovscek, Anthony R.; Schembre, Josephina
1999-08-09
A systematic experimental investigation of capillary pressure characteristics and fluid flow in diatomite was begun. Using an X-ray CT scanner and a specially constructed imbibition cell, we study spontaneous water imbibition processes in diatomite and, for reference, Berea sandstone and chalk. The mass of water imbibed as a function of time is also measured. Imbibition is restricted to concurrent flow. Despite a marked difference in rock properties such as permeability and porosity, we find similar trends in saturation profiles and weight gain versus time functions. Imbibition in diatomote is relatively rapid when initial water saturation is low due to largemore » capillary forces. Using a non-linear regression analysis together with the experimental data, the capillary pressure and water relative permeability curves are determined for the diatomite in the water-air system. The results given for displacement profiles by numerical simulation match the experimental results.« less
Miniaturized flow injection analysis system
Folta, J.A.
1997-07-01
A chemical analysis technique known as flow injection analysis is described, wherein small quantities of chemical reagents and sample are intermixed and reacted within a capillary flow system and the reaction products are detected optically, electrochemically, or by other means. A highly miniaturized version of a flow injection analysis system has been fabricated utilizing microfabrication techniques common to the microelectronics industry. The microflow system uses flow capillaries formed by etching microchannels in a silicon or glass wafer followed by bonding to another wafer, commercially available microvalves bonded directly to the microflow channels, and an optical absorption detector cell formed near the capillary outlet, with light being both delivered and collected with fiber optics. The microflow system is designed mainly for analysis of liquids and currently measures 38{times}25{times}3 mm, but can be designed for gas analysis and be substantially smaller in construction. 9 figs.
Development of novel separation techniques for biological samples in capillary electrophoresis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, Huan -Tsung
1994-07-27
This dissertation includes three different topics: general introduction of capillary electrophoresis (CE); gradient in CE and CE in biological separations; and capillary gel electrophoresis (CGE) for DNA separation. Factors such as temperature, viscosity, pH, and the surface of capillary walls affecting the separation performance are demonstrated. A pH gradient between 3.0 and 5.2 is useful to improve the resolution among eight different organic acids. A flow gradient due to the change in the concentration of surfactant, which is able to coat to the capillary wall to change the flow rate and its direction, is also shown as a good waymore » to improve the resolution for organic compounds. A temperature gradient caused by joule heat is shown by voltage programming to enhance the resolution and shorten the separation time for several phenolic compounds. The author also shows that self-regulating dynamic control of electroosmotic flow in CE by simply running separation in different concentrations of surfactant has less matrix effect on the separation performance. One of the most important demonstrations in this dissertation is that the author proposes on-column reaction which gives several advantages including the use of a small amount of sample, low risk of contamination, and time saving and kinetic features. The author uses this idea with laser induced fluorescence (LIF) as a detection mode to detect an on-column digestion of sub-ng of protein. This technique also is applied to single cell analysis in the group.« less
Retinal angiography with real-time speckle variance optical coherence tomography.
Xu, Jing; Han, Sherry; Balaratnasingam, Chandrakumar; Mammo, Zaid; Wong, Kevin S K; Lee, Sieun; Cua, Michelle; Young, Mei; Kirker, Andrew; Albiani, David; Forooghian, Farzin; Mackenzie, Paul; Merkur, Andrew; Yu, Dao-Yi; Sarunic, Marinko V
2015-10-01
This report describes a novel, non-invasive and label-free optical imaging technique, speckle variance optical coherence tomography (svOCT), for visualising blood flow within human retinal capillary networks. This imaging system uses a custom-built swept source OCT system operating at a line rate of 100 kHz. Real-time processing and visualisation is implemented on a consumer grade graphics processing unit. To investigate the quality of microvascular detail acquired with this device we compared images of human capillary networks acquired with svOCT and fluorescein angiography. We found that the density of capillary microvasculature acquired with this svOCT device was visibly greater than fluorescein angiography. We also found that this svOCT device had the capacity to generate en face images of distinct capillary networks that are morphologically comparable with previously published histological studies. Finally, we found that this svOCT device has the ability to non-invasively illustrate the common manifestations of diabetic retinopathy and retinal vascular occlusion. The results of this study suggest that graphics processing unit accelerated svOCT has the potential to non-invasively provide useful quantitative information about human retinal capillary networks. Therefore svOCT may have clinical and research applications for the management of retinal microvascular diseases, which are a major cause of visual morbidity worldwide. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Blood Vessel Adaptation with Fluctuations in Capillary Flow Distribution
Hu, Dan; Cai, David; Rangan, Aaditya V.
2012-01-01
Throughout the life of animals and human beings, blood vessel systems are continuously adapting their structures – the diameter of vessel lumina, the thickness of vessel walls, and the number of micro-vessels – to meet the changing metabolic demand of the tissue. The competition between an ever decreasing tendency of luminal diameters and an increasing stimulus from the wall shear stress plays a key role in the adaptation of luminal diameters. However, it has been shown in previous studies that the adaptation dynamics based only on these two effects is unstable. In this work, we propose a minimal adaptation model of vessel luminal diameters, in which we take into account the effects of metabolic flow regulation in addition to wall shear stresses and the decreasing tendency of luminal diameters. In particular, we study the role, in the adaptation process, of fluctuations in capillary flow distribution which is an important means of metabolic flow regulation. The fluctuation in the flow of a capillary group is idealized as a switch between two states, i.e., an open-state and a close-state. Using this model, we show that the adaptation of blood vessel system driven by wall shear stress can be efficiently stabilized when the open time ratio responds sensitively to capillary flows. As micro-vessel rarefaction is observed in our simulations with a uniformly decreased open time ratio of capillary flows, our results point to a possible origin of micro-vessel rarefaction, which is believed to induce hypertension. PMID:23029014
Gao, Bingbing; Liu, Hong; Gu, Zhongze
2014-12-23
We report a method for the bottom-up fabrication of paper-based capillary microchips by the blade coating of cellulose microfibers on a patterned surface. The fabrication process is similar to the paper-making process in which an aqueous suspension of cellulose microfibers is used as the starting material and is blade-coated onto a polypropylene substrate patterned using an inkjet printer. After water evaporation, the cellulose microfibers form a porous, hydrophilic, paperlike pattern that wicks aqueous solution by capillary action. This method enables simple, fast, inexpensive fabrication of paper-based capillary channels with both width and height down to about 10 μm. When this method is used, the capillary microfluidic chip for the colorimetric detection of glucose and total protein is fabricated, and the assay requires only 0.30 μL of sample, which is 240 times smaller than for paper devices fabricated using photolithography.
NASA Astrophysics Data System (ADS)
Kuroda, Seiichiro; Ishii, Nobuyuki; Morii, Toshihiro
2017-04-01
Recently capillary barriers have been known as a method to protect subsurface regions against infiltration from soil surface. It has essentially non-uniform structure of permeability or soil physical property. To identify the function of the capillary barrier, the site-characterization technique for non-uniform soil moisture distribution and infiltration process is needed. We built a sand box in which a thin high-permeable gravel layer was embedded and conducted a infiltration test, including non-uniform flow of soil water induced by capillary barrier effects. We monitored this process by various types of GPR measurements, including time-lapsed soundings with multi-frequency antenna and transmission measurements like one using cross-borehole radar. Finally we will discuss the applicability of GPR for monitoring the phenomena around the capillary barrier of soil. This work has partially supported by JSPS Grant-in-aid Scientific Research program, No.16H02580.
Blanco, M; Coello, J; Iturriaga, H; Maspoch, S; Pérez-Maseda, C
1998-01-09
A method for resolving the enantiomers of various 2-arylpropionic acids (viz. ketoprofen, ibuprofen and fenoprofen) by capillary zone electrophoresis (CZE) using a background electrolyte (BGE) containing a cyclodextrin as chiral selector is proposed. The effects of the type of cyclodextrin used and its concentration on resolution were studied and heptakis-2,3,6-tri- O-methyl-beta-cyclodextrin was found to be the sole effective choice for the quantitative enantiomeric resolution of all the compounds tested. The influence of pH, BGE concentration, capillary temperature and addition of methanol to the BGE on resolution and other separation-related parameters was also studied. The three compounds studied can be enantiomerically resolved with a high efficiency in a short time (less than 20 min) with no capillary treatment. This makes the proposed method suitable for assessing the enantiomeric purity of commercially available pharmaceuticals.
Boardman, Anna; McQuaide, Sarah C.; Zhu, Cuiru; Whitmore, Colin; Lidstrom, Mary E.; Dovichi, Norman J.
2009-01-01
We report a system that allows the simultaneous aspiration of one or more cells into each of five capillaries for electrophoresis analysis. A glass wafer was etched to create an array of 1 nL wells. The glass was treated with poly(2-hydroxyethyl methacrylate) to control cell adherence. A suspension of formalin-fixed cells was placed on the surface, and cells were allowed to settle. The concentration of cells and the settling time were chosen so that there was, on average, one cell per well. Next, an array of five capillaries was placed so that the tip of each capillary was in contact with a single well. A pulse of vacuum was applied to the distal end of the capillaries to aspirate the content of each well into a capillary. Next, the tips of the capillaries were placed in running buffer and potential was applied. The cells lysed upon contact with the running buffer, and fluorescent components were detected at the distal end of the capillaries by laser-induced fluorescence. The electrophoretic separation efficiency was outstanding, generating over 750,000 theoretical plates (1,800,000 plates/meter). In this example, AtT-20 cells were used that had been treated with TMR-GM1. The cells were allowed to metabolize this substrate into a series of products before the cells were fixed. The number of cells found in each well was estimated visually under the microscope and was described by a Poisson distribution with mean of 0.95 cells/well. This system provides an approach to high-throughput chemical cytometry. PMID:18717573
Capillary pumping independent of the liquid surface energy and viscosity
NASA Astrophysics Data System (ADS)
Guo, Weijin; Hansson, Jonas; van der Wijngaart, Wouter
2018-03-01
Capillary pumping is an attractive means of liquid actuation because it is a passive mechanism, i.e., it does not rely on an external energy supply during operation. The capillary flow rate generally depends on the liquid sample viscosity and surface energy. This poses a problem for capillary-driven systems that rely on a predictable flow rate and for which the sample viscosity or surface energy are not precisely known. Here, we introduce the capillary pumping of sample liquids with a flow rate that is constant in time and independent of the sample viscosity and sample surface energy. These features are enabled by a design in which a well-characterized pump liquid is capillarily imbibed into the downstream section of the pump and thereby pulls the unknown sample liquid into the upstream pump section. The downstream pump geometry is designed to exert a Laplace pressure and fluidic resistance that are substantially larger than those exerted by the upstream pump geometry on the sample liquid. Hence, the influence of the unknown sample liquid on the flow rate is negligible. We experimentally tested pumps of the new design with a variety of sample liquids, including water, different samples of whole blood, different samples of urine, isopropanol, mineral oil, and glycerol. The capillary filling speeds of these liquids vary by more than a factor 1000 when imbibed to a standard constant cross-section glass capillary. In our new pump design, 20 filling tests involving these liquid samples with vastly different properties resulted in a constant volumetric flow rate in the range of 20.96-24.76 μL/min. We expect this novel capillary design to have immediate applications in lab-on-a-chip systems and diagnostic devices.
NASA Astrophysics Data System (ADS)
Chen, Yi-Feng; Fang, Shu; Wu, Dong-Sheng; Hu, Ran
2017-09-01
Immiscible fluid-fluid displacement in permeable media is important in many subsurface processes, including enhanced oil recovery and geological CO2 sequestration. Controlled by capillary and viscous forces, displacement patterns of one fluid displacing another more viscous one exhibit capillary and viscous fingering, and crossover between the two. Although extensive studies investigated viscous and capillary fingering in porous media, a few studies focused on the crossover in rough fractures, and how viscous and capillary forces affect the crossover remains unclear. Using a transparent fracture-visualization system, we studied how the two forces impact the crossover in a horizontal rough fracture. Drainage experiments of water displacing oil were conducted at seven flow rates (capillary number log10Ca ranging from -7.07 to -3.07) and four viscosity ratios (M=1/1000,1/500,1/100 and 1/50). We consistently observed lower invading fluid saturations in the crossover zone. We also proposed a phase diagram for the displacement patterns in a rough fracture that is consistent with similar studies in porous media. Based on real-time imaging and statistical analysis of the invasion morphology, we showed that the competition between capillary and viscous forces is responsible for the saturation reduction in the crossover zone. In this zone, finger propagation toward the outlet (characteristic of viscous fingering) as well as void-filling in the transverse/backward directions (characteristic of capillary fingering), are both suppressed. Therefore, the invading fluid tends to occupy larger apertures with higher characteristic front velocity, promoting void-filling toward the outlet with thinner finger growth and resulting in a larger volume of defending fluid left behind.
LCA of waste prevention activities: a case study for drinking water in Italy.
Nessi, Simone; Rigamonti, Lucia; Grosso, Mario
2012-10-15
The strategic relevance of waste prevention has considerably increased worldwide during recent years, such that the current European legislation requires the preparation of national waste prevention programmes in which reduction objectives and measures are identified. In such a context, it is possible to recognise how, in order to correctly evaluate the environmental consequences of a prevention activity, a life cycle perspective should be employed. This allows us to go beyond the simple reduction of the generated waste which, alone, does not automatically imply achieving better overall environmental performance, especially when this reduction is not pursued through the simple reduction of consumption. In this study, the energetic and environmental performance of two waste prevention activities considered particularly meaningful for the Italian context were evaluated using life cycle assessment (LCA) methodology. The two activities were the utilisation of public network water (two scenarios) and of refillable bottled water (two scenarios) for drinking purposes, instead of one-way bottled water (three scenarios). The energy demand and specific potential impacts of the four waste prevention scenarios and of the three baseline scenarios were compared with the aim of evaluating whether, and under what conditions, the analysed prevention activities are actually associated with overall energetic and environmental benefits. In typical conditions, the use of public network water directly from the tap results in the best scenario, while if water is withdrawn from public fountains, its further transportation by private car can involve significant impacts. The use of refillable PET bottled water seems the preferable scenario for packaged water consumption, if refillable bottles are transported to local distributors along the same (or a lower) distance as one-way bottles to retailers. The use of refillable glass bottled water is preferable to one-way bottled water only if a distance beneath 150 km separates bottling plants from local distributors and retailers (except for eutrophication indicator which is always slightly worse). To reduce waste generation and to achieve meaningful potential savings of natural resources, energy and greenhouse gas emissions, a reduction in one-way bottled water consumption in Italy is recommended in favour of the use of public network water and of the establishment of short distance-PET bottles based refilling systems. The development of closed loop recycling of one-way PET bottles, and especially the reduction of the distance along which one-way bottled water is transported, are also important. Copyright © 2012 Elsevier Ltd. All rights reserved.
Characterisation of mainstream and passive vapours emitted by selected electronic cigarettes.
Geiss, Otmar; Bianchi, Ivana; Barahona, Francisco; Barrero-Moreno, Josefa
2015-01-01
Electronic cigarettes have achieved growing popularity since their introduction onto the European market. They are promoted by manufacturers as healthier alternatives to tobacco cigarettes, however debate among scientists and public health experts about their possible impact on health and indoor air quality means further research into the product is required to ensure decisions of policymakers, health care providers and consumers are based on sound science. This study investigated and characterised the impact of 'vaping' (using electronic cigarettes) on indoor environments under controlled conditions using a 30m(3) emission chamber. The study determined the composition of e-cigarette mainstream vapour in terms of propylene glycol, glycerol, carbonyls and nicotine emissions using a smoking machine with adapted smoking parameters. Two different base recipes for refill liquids, with three different amounts of nicotine each, were tested using two models of e-cigarettes. Refill liquids were analysed on their content of propylene glycol, glycerol, nicotine and qualitatively on their principal flavourings. Possible health effects of e-cigarette use are not discussed in this work. Electronic cigarettes tested in this study proved to be sources for propylene glycol, glycerol, nicotine, carbonyls and aerosol particulates. The extent of exposure differs significantly for active and passive 'vapers' (users of electronic cigarettes). Extrapolating from the average amounts of propylene glycol and glycerol condensed on the smoking machine filter pad to the resulting lung-concentration, estimated lung concentrations of 160 and 220mgm(-3) for propylene glycol and glycerol were obtained, respectively. Vaping refill liquids with nicotine concentrations of 9mgmL(-1) led to vapour condensate nicotine amounts comparable to those of low-nicotine regular cigarettes (0.15-0.2mg). In chamber studies, peak concentrations of 2200μgm(-3) for propylene glycol, 136μgm(-3) for glycerol and 0.6μgm(-3) for nicotine were reached. Carbonyls were not detected above the detection limits in chamber studies. Particles in the size range of 20nm to 300nm constantly increased during vaping activity and reached final peak concentrations of 7×10(6)particlesL(-1). Moreover, the tested products showed design flaws such as leakages from the cartridge reservoirs. Possible long term effects of e-cigarettes on health are not yet known. E-cigarettes, the impact of vaping on health and the composition of refill liquids require therefore further research into the product characteristics. The consumers would benefit from harmonised quality and safety improvements of e-cigarettes and refill liquids. Copyright © 2014 The Authors. Published by Elsevier GmbH.. All rights reserved.
Sujata, N; Arora, D; Panigrahi, B P; Hanjoora, V M
2012-04-01
Spinal anesthesia is a standard technique for cesarean section but can cause hypotension which may be related to venous pooling secondary to progesterone-induced decreases in vascular tone. This study investigated the use of a sequential compression mechanical pump with thigh-high sleeves with compression cycles timed to venous refilling. We hypothesized that this would recruit pooled venous blood from the lower limbs, maintain the central blood volume and thus decrease the incidence of hypotension. One hundred parturients scheduled for elective cesarean section under spinal anesthesia were recruited and randomly assigned to use of either a mechanical pump (Group M) or control (Group C). A standardized protocol for co-hydration and anesthesia was followed. Hypotension, defined as a decrease in systolic blood pressure by >20% from baseline, was treated with 6-mg boluses of intravenous ephedrine. The incidence of hypotension was defined as the primary outcome. Median ephedrine requirement was taken as a measure of the severity of hypotension. Hypotension occurred in 12 of 47 (25.5%) patients in Group M compared to 27 of 45 (60%) in Group C (P=0.001). The median [range] ephedrine dose was greater in Group C (12 [0-24]mg) compared to Group M (0 [0-12]mg) (P<0.001). There was no difference between groups in the time to onset of hypotension. The use of a sequential compression mechanical pump that detects venous refilling and cycles accordingly, reduced the incidence and severity of hypotension after spinal anesthesia for cesarean section. Copyright © 2012 Elsevier Ltd. All rights reserved.
Jasiński, Ryszard; Socha, Małgorzata; Sitko, Ludmiła; Kubicka, Katarzyna; Woźniewski, Marek; Sobiech, Krzysztof A
2015-03-29
Nordic walking and water aerobics are very popular forms of physical activity in the elderly population. The aim of the study was to evaluate the influence of regular health training on the venous blood flow in lower extremities and body composition in women over 50 years old. Twenty-four women of mean age 57.9 (± 3.43) years, randomly divided into three groups (Nordic walking, water aerobics, and non-training), participated in the study. The training lasted 8 weeks, with one-hour sessions twice a week. Dietary habits were not changed. Before and after training vein refilling time and the function of the venous pump of the lower extremities were measured by photoplethysmography. Body composition was determined by bioelectrical impedance. Eight weeks of Nordic walking training improved the venous blood flow in lower extremities and normalized body composition in the direction of reducing chronic venous disorder risk factors. The average values of the refilling time variable (p = 0.04, p = 0.02, respectively) decreased in both the right and the left leg. After training a statistically significant increase in the venous pump function index was found only in the right leg (p = 0.04). A significant increase in fat-free mass, body cell mass and total body water was observed (p = 0.01), whereas body mass, the body mass index, and body fat decreased (p < 0.03). With regard to water aerobic training, no similar changes in the functions of the venous system or body composition were observed.
Interaction between a pulsating jet and a surrounding disk wind. A hydrodynamical perspective
NASA Astrophysics Data System (ADS)
Tabone, B.; Raga, A.; Cabrit, S.; Pineau des Forêts, G.
2018-06-01
Context. The molecular richness of fast protostellar jets within 20-100 au of their source, despite strong ultraviolet irradiation, remains a challenge for the models investigated so far. Aim.We aim to investigate the effect of interaction between a time-variable jet and a surrounding steady disk wind, to assess the possibility of jet chemical enrichement by the wind, and the characteristic signatures of such a configuration. Methods: We have constructed an analytic model of a jet bow shock driven into a surrounding slower disk wind in the thin shell approximation. The refilling of the post bow shock cavity from below by the disk wind is also studied. An extension of the model to the case of two or more successive internal working surfaces (IWS) is made. We then compared this analytic model with numerical simulations with and without a surrounding disk wind. Results: We find that at early times (of order the variability period), jet bow shocks travel in refilled pristine disk wind material, before interacting with the cocoon of older bow shocks. This opens the possibility of bow shock chemical enrichment (if the disk wind is molecular and dusty) and of probing the unperturbed disk wind structure near the jet base. Several distinctive signatures of the presence of a surrounding disk wind are identified, in the bow shock morphology and kinematics. Numerical simulations validate our analytical approach and further show that at large scale, the passage of many jet IWS inside a disk wind produces a stationary V-shaped cavity, closing down onto the axis at a finite distance from the source.
NASA Astrophysics Data System (ADS)
Macinnis-Ng, C.; Taylor, D. T.; Kaplick, J.; Clearwater, M.
2015-12-01
Amongst the largest and longest lived conifers in the world, the endemic New Zealand kauri, Agathis australis, provides a proxy-climate record dating back 4000 y. Tree-ring widths provide a strong indicator of the occurrence of El Niño Southern Oscillation (ENSO) events. We are measuring physiological processes, including carbon uptake and loss, leaf-scale gas exchange and sap flow together with meteorological data to explore the mechanisms of the climate response of this iconic and culturally significant species. In this continuous 15 min time interval sap flow dataset spanning four years, we have captured very wet and very dry summer periods. Winter flow rates peaked lower than summer flow rates and winter flow also started later and finished earlier in the day, resulting in less water use. Larger, canopy dominant trees (DBH up to 176 cm) had large sapwood area (sapwood depth up to 18 cm) and faster flow rates and therefore dominated stand water use. During dry periods, smaller trees (DBH 20-80 cm) were more responsive to dry soils than larger trees, suggesting access to deeper soil water stores. Leaf-scale gas exchange rates were low with very low stomatal conductance values reflecting known vulnerability to xylem embolism. Night-time refilling of sapwood was particularly evident during the summer drought with evidence that refilling was incomplete as the drought progressed. Photosynthetically active radiation and vapour pressure deficit are strongly correlated with sap flow across all seasons, a promising indicator for future modelling work on this dataset. Water saving strategies and stand-scale water budgets are discussed.
Frasch, H Frederick; Barbero, Ana M
2017-11-01
Nicotine plus flavorings in a propylene glycol (PG) vehicle are the components of electronic cigarette liquids (e-liquids), which are vaporized and inhaled by the user. Dermal exposure to nicotine and e-liquids may occur among workers in mixing and filling of e-cigarettes in the manufacturing process. Inadvertent skin contact among consumers is also a concern. In vitro nicotine permeation studies using heat-separated human epidermis were performed with surrogate and two commercial e-liquids, neat and aqueous nicotine donor formulations. Steady-state fluxes (J ss ), and lag times (t lag ) were measured for each formulation. In addition, transient (4 h) exposure and finite dose (1-10 μl/cm 2 ) experiments were undertaken using one commercial e-liquid. Average J ss (μg/cm 2 /h) from formulations were: nicotine in PG (24 mg/ml): 3.97; commercial e-liquid containing menthol (25 mg/ml nicotine): 10.2; commercial e-liquid containing limonene (25 mg/ml nicotine): 23.7; neat nicotine: 175. E-liquid lag times ranged from 5 to 10 h. Absorbed fraction of nicotine from finite doses was ≈0.3 at 48 h. The data were applied to transient exposure and finite dose dermal exposure assessment models and to a simple pharmacokinetic model. Three illustrative exposure scenarios demonstrate use of the data to predict systemic uptake and plasma concentrations from dermal exposure. The data demonstrate the potential for significant nicotine absorption through skin contact with e-cigarette refill solutions and the neat nicotine used to mix them.
Retinovascular physiology and pathophysiology: new experimental approach/new insights
Puro, Donald G.
2012-01-01
An important challenge in visual neuroscience is understand the physiology and pathophysiology of the intra-retinal vasculature, whose function is required for ophthalmoception by humans and most other mammals. In the quest to learn more about this highly specialized portion of the circulatory system, a newly developed method for isolating vast microvascular complexes from the rodent retina has opened the way for using techniques such as patch-clamping, fluorescence imaging and time-lapse photography to elucidate the functional organization of a capillary network and its pre-capillary arteriole. For example, the ability to obtain dual perforated-patch recordings from well-defined sites within an isolated microvascular complex permitted the first characterization of the electrotonic architecture of a capillary/arteriole unit. This analysis revealed that this operational unit is not simply a homogenous synctium, but has a complex functional organization that is dynamically modulated by extracellular signals such as angiotensin II. Another recent discovery is that a capillary and its pre-capillary arteriole have distinct physiological differences; capillaries have an abundance of ATP-sensitive potassium (KATP) channels and a dearth of voltage-dependent calcium channels (VDCCs) while the converse is true for arterioles. In addition, voltage transmission between abluminal cells and the endothelium is more efficient in the capillaries. Thus, the capillary network is well-equipped to generate and transmit voltages, and the pre-capillary arteriole is well-adapted to transduce a capillary-generated voltage into a change in abluminal cell calcium and thereby, a vasomotor response. Use of microvessels isolated from the diabetic retina has led to new insights concerning retinal vascular pathophysiology. For example, soon after the onset of diabetes, the efficacy of voltage transmission through the endothelium is diminished; arteriolar VDCCs is inhibited, and there is increased vulnerability to purinergic vasotoxicity, which is a newly identified pathobiological mechanism. Other recent studies reveal that KATP channels not only have an essential physiological role in generating vasomotor responses, but their activation substantially boosts the lethality of hypoxia. Thus, the pathophysiology of the retinal microvasculature is closely linked with its physiology. PMID:22333041
Mori, Masanobu; Yamamoto, Tsukasa; Kaseda, Maki; Yamada, Sachiko; Itabashi, Hideyuki
2012-03-01
A combination of polyvinyl alcohol chemically coated capillary (PVA capillary) and background electrolyte (BGE) with ion-pair reagent (hexamethonium dichloride, HMC) was used on capillary ion electrophoresis-UV detection (CIE-UV) for analysis of Br⁻, I⁻, NO₂⁻, NO₃⁻, SCN⁻ and uric acid in human saliva. The PVA capillary prepared in our laboratory minimized electro-osmotic flow (EOF) at the BGE in pH 3-10, and did not affect the UV detection at 210 nm by the PVA-layer on capillary wall. Therefore, use of the PVA capillary was suitable for sensitive UV detection for analyte anions, as well as suppression of protein adsorption. In this study, we optimized the BGE of 10 mM phosphate plus 10 mM HMC with applying a voltage of -15 kV. HMC as an additive to BGE could manipulate the electrophoretic mobility of anions, without electrostatic adsorption to the PVA capillary. The CIE-UV could separate and determine analyte anions in human saliva containing proteins by the direct injection without pretreatments such as dilution or deproteinization within 13 min. The relative standard deviations (n=10) were ranged of 0.5-1.6% in migration times, 2.2-6.8% in peak heights and 2.8-8.4% in peak areas. The limits of detection (S/N=3) were ranged of 3.42-6.87 μM. The peak height of anions in this system was gradually decreased through the successive injections of saliva samples, but the problem was successfully solved by periodically conditioning the PVA capillary. The quantifiability of anions in human saliva samples by the CIE-UV was evaluated through the recoveries by standard addition methods and comparison of other representative analytical methods, as well as identification by ion chromatography (IC). From the anion analyses in 12 different saliva samples, the CIE-UV demonstrated that can obtain obvious differences in concentrations of SCN⁻ between of smoker and non-smoker and those of uric acid between male and female with satisfactory results. Copyright © 2012 Elsevier B.V. All rights reserved.
Fetal villosity and microvasculature of the bovine placentome in the second half of gestation
LEISER, R.; KREBS, C.; KLISCH, K.; EBERT, B.; DANTZER, V.; SCHULER, G.; HOFFMANN, B.
1997-01-01
The architecture of the fetal villous tree and its vasculature in the bovine placentome were studied in the second half of gestation using both conventional histology and histology of ink-filled blood vessels. These were compared with corrosion casts of plastic fillings of the vasculature, prepared for scanning electron microscopy. This combination of morphological methods allows perception of the villous tree throughout gestation from broad-conical to tall-conical form where branch ramification occurs mainly at right angles to the stem. The stem villus typically contains a single central artery and several peripheral veins arranged in parallel. The proximal branches to the stem, the intermediate villi, contain a central arteriole and accompanying venules. The distal branches, the terminal villi, enclose capillary convolutions which consist of an afferent arterial capillary limb, capillary loops and efferent venous capillary limbs. Vascular interconnections exist within the terminal villi, as capillaries or venules between the capillary convolutions, serially bridging them in up to 5 places, and as capillary anastomoses between the capillary loops. Coiling and sinusoidal dilatations of these loops develop near the end of gestation. The intraplacentomal rearrangement of villous trees with progressive gestation and their morphological vascular adaptations are discussed in relation to placental function, including the ever increasing need for transplacental substance exchange. This adaptation allows the blood to traverse the shortest possible arterioarteriolar route to the periphery of the trees where exchange takes place. The need for an increasing blood flow stimulates capillary growth and at the same time optimises the blood flow reaching the placental barrier represented by the vessel cast surface. The capillaries also carry the blood back into the very voluminous system of venules and veins where back diffusion may occur. The total volume of terminal villi of bovine placentome, the ‘working part’ of villous trees, hence distinctly increases with respect to the stem and intermediate villi, the ‘supplying part’ of the villous tree. In morphological terms the efficiency of the bovine transplacental diffusional exchange is higher than in the closely related ‘co-ruminants’ sheep and goats and distinctly higher when compared with the human placenta. PMID:9449071
NASA Technical Reports Server (NTRS)
Sojka, J. J.; Schunk, R. W.; Johnson, J. F. E.; Waite, J. H.; Chappell, C. R.
1983-01-01
The thermal and suprathermal ion populations present in the refilling regions after a magnetic storm are examined using retarding ion mass spectrometer (RIMS) data from the Dynamics Explorer 1 spacecraft. The RIMS instrument is described, and data are presented and discussed in detail for the outer plasmasphere, plasmapause, depleted dayside magnetosphere, and dayside cusp. Three distinct populations were observed: thermal ions, warm anisotropic plasma, and the polar wind. The characteristics of these populations are considered, including the densities, temperatures, and density ratios. Aspects of the ionospheric plasma outflow are discussed, including the field-aligned flow speed, the ionospheric plasma escape flux, plasmaspheric refilling, and wave-particle phenomena.
[Capillary HbA1c determination on type 2 diabetes patients in a primary health centre].
Font, María Teresa Carrera; Brichs, María Claustre Solé; Álvarez, María Clara Sala; Olivella, Jose María Navarro; Turó, Josefina Servent; Fernández, María Pilar Felipe
2011-10-01
To determine the reliability and practicability of the point-of-care- test (POCT) analyzer, Afinion, for capillary HbA1c testing. To assess the benefits of its implementation on the intra-annual follow up of type 2 diabetic patients. Descriptive cross-sectional study. Analytical validation of the Afinion reader. Primary Health Care (CAP Carmel and Bon Pastor Clinic Laboratory). A total of 94 type 2 diabetic patients selected according to their previous HbA1c value. We performed one capillary puncture and one venous extraction on each visit. The capillary sample was assessed in real time on the Afinion in the Primary Health Care Centre and the venous sample was sent to Bon Pastor Clinic Laboratory for assessment on an Afinion analyzer and by a high performance liquid chromatrography (HPLC) reference method. Practicability was assesses by both by the operators of the Afinion and the patients using an 11 question questionnaire. The efficiency in terms of process timings was also evaluated. Intra-serial coefficient of variation (CV) was lower than 1% and inter-serial lower than 3%. The regression analysis showed: Afinion capillary sample=0.95 Afinion venous+0.21. No systematic or proportional error was detected in the 95% confidence interval (95% CI). The comparison between venous HPLC and Afinion showed: Afinion capillary sample=0.80 HPLC+1.14. A statistically significant difference was shown for these values at the 95% CI. Practicability was valued by users from 7 to 9.2 (professionals) and from 7.7 to 9.2 (patients). Implementation of the Afinion capillary method for intra-annual testing in follow up of diabetic patients could result in the saving of 600-900 professional hours/year. Afinion seems to be a good choice for the intra-annual determination of HbA1c when compared to the traditional process due to its accessibility, practicability and efficiency. Professionals should know the limitations of the POCT method in order to consider the validity of the results. Copyright © 2010 Elsevier España, S.L. All rights reserved.
NASA Astrophysics Data System (ADS)
Desrochers, Johanne; Vermette, Patrick; Fontaine, Réjean; Bérubé-Lauzière, Yves
2009-02-01
Current efforts in tissue engineering target the growth of 3D volumes of tissue cultures in bioreactor conditions. Fluorescence optical tomography has the potential to monitor cells viability and tissue growth non-destructively directly within the bioreactor via bio-molecular fluorescent labelling strategies. We currently work on developing the imaging instrumentation for tissue cultures in bioreactor conditions. Previously, we localized in 3D thin fluorescent-labelled capillaries in a cylindrically shaped bioreactor phantom containing a diffusive medium with our time-of-flight localization technique. Here, we present our first reconstruction results of the spatial distribution of fluorophore concentrations for labelled capillaries embedded in a bioreactor phantom.
Simulation of the dynamical transmission of several-hundred-keV protons through a conical capillary
NASA Astrophysics Data System (ADS)
Yang, A. X.; Zhu, B. H.; Niu, S. T.; Pan, P.; Han, C. Z.; Song, H. Y.; Shao, J. X.; Chen, X. M.
2018-05-01
The time evolution of the trajectories, angular distributions, and two-dimensional images of intermediate-energy protons being transmitted through a conical capillary was simulated. The simulation results indicate that the charge deposited in the capillary significantly enhances the probability of surface specular scattering and thus greatly enhances the transmission rate. Furthermore, this deposited-charge-assisted specular reflection causes the transmission rate to exhibit an energy dependence proportional to E-1, which is very consistent with the experimental data. After transmission at nonzero tilt angles, the angular distribution of several-hundred-keV protons is far from symmetric, unlike in the case of keV protons.
Dynamics and Stability of Capillary Surfaces: Liquid Switches at Small Scales
NASA Technical Reports Server (NTRS)
Steen, Paul H.; Bhandar, Anand; Vogel, Michael J.; Hirsa, Amir H.
2004-01-01
The dynamics and stability of systems of interfaces is central to a range of technologies related to the Human Exploration and Development of Space (HEDS). Our premise is that dramatic shape changes can be manipulated to advantage with minimal input, if the system is near instability. The primary objective is to develop the science base to allow novel approaches to liquid management in low-gravity based on this premise. HEDS requires efficient, reliable and lightweight technologies. Our poster will highlight our progress toward this goal using the capillary switch as an example. A capillary surface is a liquid/liquid or liquid/gas interface whose shape is determined by surface tension. For typical liquids (e.g., water) against gas on earth, capillary surfaces occur on the millimeterscale and smaller where shape deformation due to gravity is unimportant. In low gravity, they can occur on the centimeter scale. Capillary surfaces can be combined to make a switch a system with multiple stable states. A capillary switch can generate motion or effect force. To be practical, the energy barriers of such a switch must be tunable, its switching time (kinetics) short and its triggering mechanism reliable. We illustrate these features with a capillary switch that consists of two droplets, coupled by common pressure. As long as contact lines remained pinned, motions are inviscid, even at sub-millimeter scales, with consequent promise of low-power consumption at the device level. Predictions of theory are compared to experiment on i) a soap-film prototype at centimeter scale and ii) a liquid droplet switch at millimeter-scale.
Ji, Hongyun; Li, Meng; Guo, Lihong; Yuan, Hongyan; Wang, Chunling; Xiao, Dan
2013-09-01
A new detector, capillary coupled with optical fiber LED-induced fluorescence detector (CCOF-LED-IFD, using CCOF for short), is introduced for CE. The strategy of the present work was that the optical fiber and separation capillary were, in the parallel direction, fastened in a fixation capillary with larger inner diameter. By employing larger inner diameter, the fixation capillary allowed the large diameter of the optical fiber to be inserted into it. By transmitting an enhanced excitation light through the optical fiber, the detection sensitivity was improved. The advantages of the CCOF-CE system were validated by the detection of riboflavin, and the results were compared to those obtained by the in-capillary common optical fiber LED-induced fluorescence detector (IC-COF-LED-IFD, using COF for short). The LODs of CCOF-CE and COF-CE were 0.29 nM and 11.0 nM (S/N = 3), respectively. The intraday (n = 6) repeatability and interday (n = 6) reproducibility of migration time and corresponding peak area for both types of CE were all less than 1.10 and 3.30%, respectively. The accuracy of the proposed method was judged by employing standard addition method, and recoveries obtained were in the range of 98.0-102.4%. The results indicated that the sensitivity of the proposed system was largely improved, and that its reproducibility and accuracy were satisfactory. The proposed system was successfully applied to separate and determine riboflavin in real sample. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Estimation of relative permeability and capillary pressure from mass imbibition experiments
NASA Astrophysics Data System (ADS)
Alyafei, Nayef; Blunt, Martin J.
2018-05-01
We perform spontaneous imbibition experiments on three carbonates - Estaillades, Ketton, and Portland - which are three quarry limestones that have very different pore structures and span wide range of permeability. We measure the mass of water imbibed in air saturated cores as a function of time under strongly water-wet conditions. Specifically, we perform co-current spontaneous experiments using a highly sensitive balance to measure the mass imbibed as a function of time for the three rocks. We use cores measuring 37 mm in diameter and three lengths of approximately 76 mm, 204 mm, and 290 mm. We show that the amount imbibed scales as the square root of time and find the parameter C, where the volume imbibed per unit cross-sectional area at time t is Ct1/2. We find higher C values for higher permeability rocks. Employing semi-analytical solutions for one-dimensional flow and using reasonable estimates of relative permeability and capillary pressure, we can match the experimental data. We finally discuss how, in combination with conventional measurements, we can use theoretical solutions and imbibition measurements to find or constrain relative permeability and capillary pressure.
Kubo, Yoshiyuki; Seko, Narumi; Usui, Takuya; Akanuma, Shin-Ichi; Hosoya, Ken-Ichi
2016-01-01
Lysosomal trapping was investigated in the retinal capillary endothelial cells that are responsible for the inner blood-retinal barrier (BRB) using LysoTracker(®) Red (LTR). Using confocal microscopy on TR-iBRB2 cells, an in vitro model of the inner BRB, the presence of lysosomal trapping in retinal capillary endothelial cells was suggested since TR-iBRB2 cells exhibited punctuate intracellular localization of LTR that was attenuated by NH4Cl treatment. The study confirmed that LTR uptake by retinal capillary endothelial cells took place in a time- and temperature-dependent manner, and exhibited the 1.58-fold greater uptake at pH 8.4 than that at pH 7.4 while there was no change in uptake between pH 6.4 and pH 7.4, suggesting that passive diffusion is not enough to explain LTR uptake. The inhibition study showed the possible influence of lysosomal trapping on cationic drug transport by retinal capillary endothelial cells since LTR uptake was significantly inhibited by cationic amphiphilic drugs. Inhibition profiling and the estimation of IC50 suggested the influence of lysosomal trapping on propranolol and low-affinity pyrilamine transport while lysosomal trapping had only a partial effect on verapamil, clonidine, nicotine and high-affinity pyrilamine transport in retinal capillary endothelial cells.