Capsule enteroscopy; Wireless capsule endoscopy; Video capsule endoscopy (VCE); Small bowel capsule endoscopy (SBCE) ... a computer and software turns them into a video. Your provider watches the video to look for ...
Krok, Karen L.; Wagennar, Rebecca Rankin; Kantsevoy, Sergey V.
2016-01-01
Introduction Capsule endoscopy has been suggested as a potential alternative to endoscopy for detection of esophagogastric varices and severe portal hypertensive gastropathy (PHG). The aim of the study was to determine whether PillCam esophageal capsule endoscopy could replace endoscopy for screening purposes. Material and methods Sixty-two patients with cirrhosis with no previous variceal bleeding had PillCam capsule endoscopy and video endoscopy performed on the same day. Sensitivity, specificity, and positive and negative predictive values (PPV, NPV) of capsule endoscopy were compared to endoscopy for the presence and severity of esophageal and gastric varices, PHG and the need for primary prophylaxis. Patients’ preference was assessed by a questionnaire. Results Four (6%) patients were unable to swallow the capsule. Sensitivity, specificity, PPV and NPV of capsule endoscopy for detecting any esophageal varices (92%, 50%, 92%, 50%), large varices (55%, 91%, 75%, 80%), variceal red signs (58%, 87%, 69%, 80%), PHG (95%, 50%, 95%, 50%), and the need for primary prophylaxis (91%, 57%, 78%, 80%) were not optimal, with only moderate agreement (κ) between capsule and upper GI endoscopy. Had only a capsule endoscopy been performed, 12 (21.4%) patients would have received inappropriate treatment. Capsule endoscopy also failed to detect (0/13) gastric varices. The majority of patients ranked capsule endoscopy as more convenient (69%) and their preferred (61%) method. Conclusions Despite the preference expressed by patients for capsule endoscopy, we believe that upper GI endoscopy should remain the preferred screening method for primary prophylaxis. PMID:27186182
Gubler, C; Fox, M; Hengstler, P; Abraham, D; Eigenmann, F; Bauerfeind, P
2007-12-01
Capsule endoscopy is widely used for diagnosis of small-bowel disease; however, the impact of capsule endoscopy on clinical management remains uncertain. We conducted a prospective study of the impact capsule endoscopy on clinical management decisions in 128 patients with suspected small-bowel pathology. Prior to performing each procedure the gastroenterologist predicted the findings of capsule endoscopy and further management based on the clinical history and previous investigations. This prediction was compared with the actual results of capsule endoscopy and the following investigative and therapeutic management. The actual findings of capsule endoscopy and the further management were consistent with clinical prediction in 93/128 patients (73 %) and, irrespective of capsule endoscopy findings, no further procedures were required in 80 % of these patients. In 13 patients (10 %), gastric or colonic pathology was discovered that had not been detected on prior gastroscopy or colonoscopy. Thus, capsule endoscopy findings in the small bowel changed clinical management in 22 patients (17 %). In 4 patients, positive findings on capsule endoscopy that had not been predicted by the examiner prompted referral for abdominal surgery. Conversely, planned surgery was canceled in four other patients. In this series of patients referred for capsule endoscopy, small-bowel findings and appropriate clinical management were predicted on clinical grounds alone in approximately three-quarters of patients. Repetition of standard upper and lower endoscopy may be useful in many patients prior to small-bowel imaging. Referral for capsule endoscopy should take into account whether the findings will impact on clinical management; however, capsule endoscopy is mandatory in patients in whom surgery for small-bowel bleeding is intended.
Filip, Dobromir; Yadid-Pecht, Orly; Muench, Gregory; Mintchev, Martin P; Andrews, Christopher N
2013-02-01
Capsule endoscopy is a noninvasive method for examining the small intestine. Recently, this method has been used to visualize the colon. However, the capsule often tumbles in the wider colon lumen, resulting in potentially missed pathology. In addition, the capsule does not have the ability to distend collapsed segments of the organ. Self-stabilizing capsule endoscopy is a new method of visualizing the colon without tumbling and with the ability to passively distend colon walls. To quantitatively compare the detection rate of intraluminal suture marker lesions for colonoscopy by using a custom-modified, self-stabilizing capsule endoscope (SCE); an unmodified capsule endoscope (CE) of the same brand; and a standard colonoscope. Four mongrel dogs underwent laparotomy and the implantation of 5 to 8 suture markers to approximate colon lesions. Each dog had both capsule endoscopy and self-stabilizing capsule endoscopy, administered consecutively in random order. In each case, the capsule was inserted endoscopically into the proximal lumen of the colon followed by pharmacologically induced colon peristalsis to propel it distally through the colon. Blinded standard colonoscopy was performed by an experienced gastroenterologist after the capsule endoscopies. Experimental study in a live canine model. Four dogs. Laparotomy, capsule endoscopy, colonoscopy. Comparison of the marker detection rate of the SCE to that of the unmodified MiroCam CE and a colonoscope. The average percentages of the marker detection rate for unmodified capsule endoscopy, self-stabilizing capsule endoscopy, and colonoscopy, respectively, were 31.1%, 86%, and 100% (P < .01), with both self-stabilizing capsule endoscopy and colonoscopy performing significantly better than the unmodified capsule endoscopy. Acute canine model, suture markings poorly representative of epithelial polyps, limited number of animals. The proposed self-stabilizing capsule endoscope delivered a significant improvement in detection rates of colon suture markings when compared with the unmodified capsule endoscope. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Colon Capsule Endoscopy for the Detection of Colorectal Polyps: An Economic Analysis
Palimaka, Stefan; Blackhouse, Gord; Goeree, Ron
2015-01-01
Background Colorectal cancer is a leading cause of mortality and morbidity in Ontario. Most cases of colorectal cancer are preventable through early diagnosis and the removal of precancerous polyps. Colon capsule endoscopy is a non-invasive test for detecting colorectal polyps. Objectives The objectives of this analysis were to evaluate the cost-effectiveness and the impact on the Ontario health budget of implementing colon capsule endoscopy for detecting advanced colorectal polyps among adult patients who have been referred for computed tomographic (CT) colonography. Methods We performed an original cost-effectiveness analysis to assess the additional cost of CT colonography and colon capsule endoscopy resulting from misdiagnoses. We generated diagnostic accuracy data from a clinical evidence-based analysis (reported separately), and we developed a deterministic Markov model to estimate the additional long-term costs and life-years lost due to false-negative results. We then also performed a budget impact analysis using data from Ontario administrative sources. One-year costs were estimated for CT colonography and colon capsule endoscopy (replacing all CT colonography procedures, and replacing only those CT colonography procedures in patients with an incomplete colonoscopy within the previous year). We conducted this analysis from the payer perspective. Results Using the point estimates of diagnostic accuracy from the head-to-head study between colon capsule endoscopy and CT colonography, we found the additional cost of false-positive results for colon capsule endoscopy to be $0.41 per patient, while additional false-negatives for the CT colonography arm generated an added cost of $116 per patient, with 0.0096 life-years lost per patient due to cancer. This results in an additional cost of $26,750 per life-year gained for colon capsule endoscopy compared with CT colonography. The total 1-year cost to replace all CT colonography procedures with colon capsule endoscopy in Ontario is about $2.72 million; replacing only those CT colonography procedures in patients with an incomplete colonoscopy in the previous year would cost about $740,600 in the first year. Limitations The difference in accuracy between colon capsule endoscopy and CT colonography was not statistically significant for the detection of advanced adenomas (≥ 10 mm in diameter), according to the head-to-head clinical study from which the diagnostic accuracy was taken. This leads to uncertainty in the economic analysis, with results highly sensitive to changes in diagnostic accuracy. Conclusions The cost-effectiveness of colon capsule endoscopy for use in patients referred for CT colonography is $26,750 per life-year, assuming an increased sensitivity of colon capsule endoscopy. Replacement of CT colonography with colon capsule endoscopy is associated with moderate costs to the health care system. PMID:26366240
Safety of capsule endoscopy using human body communication in patients with cardiac devices.
Chung, Joo Won; Hwang, Hye Jin; Chung, Moon Jae; Park, Jeong Youp; Pak, Hui-Nam; Song, Si Young
2012-06-01
The MiroCam (IntroMedic, Ltd., Seoul, Korea) is a small-bowel capsule endoscope that uses human body communication to transmit data. The potential interactions between cardiac devices and the capsule endoscope are causes for concern, but no data are available for this matter. This clinical study was designed to evaluate the potential influence of the MiroCam capsules on cardiac devices. Patients with cardiac pacemakers or implantable cardiac defibrillators referred for evaluation of small bowel disease were prospectively enrolled in this study. Before capsule endoscopy, a cardiologist checked baseline electrocardiograms and functions of the cardiac devices. Cardiac rhythms were continuously monitored by 24-h telemetry during capsule endoscopy in the hospital. After completion of procedures, functions of the cardiac devices were checked again for interference. Images from the capsule endoscopy were reviewed and analyzed for technical problems. Six patients, three with pacemakers and three with implantable cardiac defibrillators, were included in the study. We identified no disturbances in the cardiac devices and no arrhythmias detected on telemetry monitoring during capsule endoscopy. No significant changes in the programmed parameters of the cardiac devices were noted after capsule endoscopy. There were no imaging disturbances from the cardiac devices on capsule endoscopy. Capsule endoscopy using human body communication to transmit data was safely performed in patients with cardiac pacemakers or implantable cardiac defibrillators. Images from the capsule endoscopy were not affected by cardiac devices. A further large-scale study is required to confirm the safety of capsule endoscopy with various types of cardiac devices.
Capsule Endoscopy in the Assessment of Obscure Gastrointestinal Bleeding: An Economic Analysis
Palimaka, S; Blackhouse, Gord; Goeree, Ron
2015-01-01
Background Small-bowel capsule endoscopy is a tool used to visualize the small bowel to identify the location of bleeds in obscure gastrointestinal bleeding (OGIB). Capsule endoscopy is currently funded in Ontario in cases where there has been a failure to identify a source of bleeding via conventional diagnostic procedures. In Ontario, capsule endoscopy is a diagnostic option for patients whose findings on esophagogastroduodenoscopy, colonoscopy, and push enteroscopy have been negative (i.e., the source of bleeding was not found). Objectives This economic analysis aims to estimate the budget impact of different rates of capsule endoscopy use as a complement to push enteroscopy procedures in patients aged 18 years and older. Data Sources Population-based administrative databases for Ontario were used to identify patients receiving push enteroscopy and small-bowel capsule endoscopy in the fiscal years 2008 to 2012. Review Methods A systematic literature search was performed to identify economic evaluations of capsule endoscopy for the investigation of OGIB. Studies were assessed for their methodological quality and their applicability to the Ontarian setting. An original budget impact analysis was performed using data from Ontarian administrative sources and published literature. The budget impact was estimated for different levels of use of capsule endoscopy as a complement to push enteroscopy due to the uncertain clinical utility of the capsule based on current clinical evidence. The analysis was conducted from the provincial public payer perspective. Results With varying rates of capsule endoscopy use, the budgetary impact spans from savings of $510,000,1 when no (0%) push enteroscopy procedures are complemented with capsule endoscopy, to $2,036,000, when all (100%) push enteroscopy procedures are complemented with capsule endoscopy. A scenario where 50% of push enteroscopy procedures are complemented with capsule endoscopy (expected use based on expert opinion) would result in additional expenditure of about $763,000. Limitations In the literature on OGIB, estimates of rebleeding rates after endoscopic procedures or spontaneous cessation rates are unreliable, with a lack of data. Rough estimates from expert consultation can provide an indication of expected additional use of capsule endoscopy; however, a wide range of capsule uses was explored. Conclusions The budgetary impact in the first year in Ontario of capsule endoscopy use to complement push enteroscopy procedures ranges from $510,000 in savings to an additional expenditure of $2,036,000 (at 0% and 100% push enteroscopy procedures complemented, respectively). The expected scenario of 50% of push enteroscopy procedures likely to benefit from the use of capsule endoscopy, based on expert opinion, would result in additional expenditures of $763,000 in the first year. PMID:26355732
Aihole, Jayalaxmi S; Vishnumurthy, G S; Babu, M Narendra
2016-11-15
Capsule endoscopy was invented to visualize the entire small intestine in a non- invasive manner in adults. 1 y, 9 mo-old boy presented with generalized edema for last 3 months. His routine investigations, including the upper gastrointestinal endoscopy, colonoscopy, and contrast enhanced computed tomography scan (CECT) were normal. In view of clinical suspicion of protein losing enteropathy, we planned capsule endoscopy. The capsule was not passed even after 3 weeks. Laparoscopy revealed impacted capsule in a dilated intestinal loop proximal to an ileal stricuture. Capsule endoscopy should be used judiciously in children.
Capsule endoscopy: no longer limited to the small bowel.
Niv, Yaron
2010-03-01
Capsule endoscopy is the latest evolution in gastrointestinal endoscopy and the first to enable complete investigation of the small bowel. Recent new developments in the field of capsule endoscopy include the esophageal capsule (Pilcam ESO) and the colonic capsule (PillCam Colon). esophageal and colonic capsules have two heads with two lenses and cameras. The new capsules have the capability of taking more frames from both sides. The indications for the esophageal capsule examination are diagnosis and follow-up of Barrett's esophagus and esophageal varices. The colonic capsule can be used for colorectal cancer screening and for incomplete colonoscopy. Regarding other new technologies, continuous quality control is needed for the performance, appropriateness of the indications, diagnostic yield, procedure-specific outcome assessment, and cost-effectiveness.
Ethical aspects of capsule endoscopy.
Niv, Yaron
2008-01-01
Capsule endoscopy is the most recent innovation in gastrointestinal endoscopy. The capsule contains a video camera that photographs the bowel for 8 h after the capsule has been orally ingested and transmits the images for interpretation to a computerized workstation. Ethical considerations of the use of capsule endoscopy should cover the following main issues: justification of the procedure, its potential benefits and harm, and patient autonomy. Capsule endoscopy has several advantages over traditional endoscopy. The procedure is painless, does not require sedation, is easy to perform and for the first time enables exploration of the entire small bowel at high magnification. However, the clinician cannot control its passive advance along the bowel. In addition, the examination may be incomplete, as the capsule reaches the cecum in only 80% of cases. This paper discusses the problems related to the new endoscopic procedure, the diagnostic yield in comparison with other procedures, proper indications for the procedure, outcome and complications. Copyright 2008 S. Karger AG, Basel.
Albert, Jörg; Göbel, Christa-Maria; Lesske, Joachim; Lotterer, Erich; Nietsch, Hubert; Fleig, Wolfgang E
2004-04-01
Capsule endoscopy is a new imaging method for visualization of the entire small bowel. However, no standardized protocol for bowel preparation for capsule endoscopy has been evaluated. Capsule endoscopy was performed in 36 consecutive patients, all of whom fasted for 12 hours before ingestion of the capsule. Before capsule endoscopy, 18 patients received 80 mg simethicone and 18 had no supplemental medication for bowel preparation. Two observers, both experienced endoscopists, independently reviewed the examinations in a single-blinded and randomly assigned fashion. Mucosal visibility and intraluminal gas bubbles were assessed and graded by both observers. Bowel preparation with simethicone resulted in significantly better visibility because of fewer intraluminal bubbles (p<0.01). Interobserver agreement was excellent (r>/=0.8; k 0.78: 95% CI[0.57, 0.98] ). No adverse effect of simethicone was observed. Simethicone may be added to the routine preparation for capsule endoscopy to improve the visibility of small bowel mucosa.
Role of capsule endoscopy in inflammatory bowel disease.
Kopylov, Uri; Seidman, Ernest G
2014-02-07
Videocapsule endoscopy (VCE) has revolutionized our ability to visualize the small bowel mucosa. This modality is a valuable tool for the diagnosis of obscure small bowel Crohn's disease (CD), and can also be used for monitoring of disease activity in patients with established small-bowel CD, detection of complications such as obscure bleeding and neoplasms, evaluation of response to anti-inflammatory treatment and postoperative recurrence following small bowel resection. VCE could also be an important tool in the management of patients with unclassified inflammatory bowel disease, potentially resulting in reclassification of these patients as having CD. Reports on postoperative monitoring and evaluation of patients with ileal pouch-anal anastomosis who have developed pouchitis have recenty been published. Monitoring of colonic inflammatory activity in patients with ulcerative colitis using the recently developed colonic capsule has also been reported. Capsule endoscopy is associated with an excellent safety profile. Although retention risk is increased in patients with small bowel CD, this risk can be significanty decreased by a routine utilization of a dissolvable patency capsule preceding the ingestion of the diagnostic capsule. This paper contains an overview of the current and future clinical applications of capsule endoscopy in inflammatory bowel disease.
Effect of small bowel preparation with simethicone on capsule endoscopy.
Fang, You-hong; Chen, Chun-xiao; Zhang, Bing-ling
2009-01-01
Capsule endoscopy is a novel non-invasive method for visualization of the entire small bowel. The diagnostic yield of capsule endoscopy depends on the quality of visualization of the small bowel mucosa and its complete passage through the small bowel. To date, there is no standardized protocol for bowel preparation before capsule endoscopy. The addition of simethicone in the bowel preparation for the purpose of reducing air bubbles in the intestinal lumen had only been studied by a few investigators. Sixty-four participants were randomly divided into two groups to receive a bowel preparation of polyethylene glycol (PEG) solution (Group 1) and both PEG solution and simethicone (Group 2). The PEG solution and simethicone were taken the night before and 20 min prior to capsule endoscopy, respectively. Frames taken in the small intestine were examined and scored for luminal bubbles by two professional capsule endoscopists. Gastric emptying time and small bowel transit time were also recorded. Simethicone significantly reduced luminal bubbles both in the proximal and distal small intestines. The mean time proportions with slight bubbles in the proximal and distal intestines in Group 2 were 97.1% and 99.0%, respectively, compared with 67.2% (P<0.001) and 68.8% (P<0.001) in Group 1. Simethicone had no effect on mean gastric emptying time, 32.08 min in Group 2 compared with 30.88 min in Group 1 (P=0.868), but it did increase mean small intestinal transit time from 227.28 to 281.84 min (P=0.003). Bowel preparation with both PEG and simethicone significantly reduced bubbles in the intestinal lumen and improved the visualization of the small bowel by capsule endoscopy without any side effects observed.
Effect of small bowel preparation with simethicone on capsule endoscopy*
Fang, You-hong; Chen, Chun-xiao; Zhang, Bing-ling
2009-01-01
Background: Capsule endoscopy is a novel non-invasive method for visualization of the entire small bowel. The diagnostic yield of capsule endoscopy depends on the quality of visualization of the small bowel mucosa and its complete passage through the small bowel. To date, there is no standardized protocol for bowel preparation before capsule endoscopy. The addition of simethicone in the bowel preparation for the purpose of reducing air bubbles in the intestinal lumen had only been studied by a few investigators. Methods: Sixty-four participants were randomly divided into two groups to receive a bowel preparation of polyethylene glycol (PEG) solution (Group 1) and both PEG solution and simethicone (Group 2). The PEG solution and simethicone were taken the night before and 20 min prior to capsule endoscopy, respectively. Frames taken in the small intestine were examined and scored for luminal bubbles by two professional capsule endoscopists. Gastric emptying time and small bowel transit time were also recorded. Results: Simethicone significantly reduced luminal bubbles both in the proximal and distal small intestines. The mean time proportions with slight bubbles in the proximal and distal intestines in Group 2 were 97.1% and 99.0%, respectively, compared with 67.2% (P<0.001) and 68.8% (P<0.001) in Group 1. Simethicone had no effect on mean gastric emptying time, 32.08 min in Group 2 compared with 30.88 min in Group 1 (P=0.868), but it did increase mean small intestinal transit time from 227.28 to 281.84 min (P=0.003). Conclusion: Bowel preparation with both PEG and simethicone significantly reduced bubbles in the intestinal lumen and improved the visualization of the small bowel by capsule endoscopy without any side effects observed. PMID:19198022
Double-balloon endoscopy as the primary method for small-bowel video capsule endoscope retrieval.
Van Weyenberg, Stijn J B; Van Turenhout, Sietze T; Bouma, Gerd; Van Waesberghe, Jan Hein T M; Van der Peet, Donald L; Mulder, Chris J J; Jacobs, Maarten A J M
2010-03-01
Capsule retention in the small bowel is a known complication of small-bowel video capsule endoscopy. Surgery is the most frequently used method of capsule retrieval. To determine the incidence and causes of capsule retention and to describe double-balloon endoscopy (DBE) as the primary technique used for capsule retrieval. Retrospective analysis of all video capsule studies was performed at our center, and evaluation of the outcome of DBE was the first method used to retrieve entrapped video capsules. Tertiary referral center. A total of 904 patients who underwent small-bowel video capsule endoscopy. Capsule retrieval by DBE. The number of patients in whom capsule retention occurred and the number of patients in whom an entrapped capsule could be retrieved by using DBE. Capsule retention occurred in 8 patients (incidence 0.88%; 95% CI, 0.41%-1.80%) and caused acute small-bowel obstruction in 6 patients. All retained capsules were successfully removed during DBE. Five patients underwent elective surgery to treat the underlying cause of capsule retention. One patient required emergency surgery because of multiple small-bowel perforations. Retrospective design. In our series, the incidence of capsule retention was low. DBE is a reliable method for removing retained capsules and might prevent unnecessary surgery. If surgery is required, preoperative capsule retrieval allows preoperative diagnosis, adequate staging in case of malignancy, and optimal surgical planning. 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Magnetically guided capsule endoscopy.
Shamsudhin, Naveen; Zverev, Vladimir I; Keller, Henrik; Pane, Salvador; Egolf, Peter W; Nelson, Bradley J; Tishin, Alexander M
2017-08-01
Wireless capsule endoscopy (WCE) is a powerful tool for medical screening and diagnosis, where a small capsule is swallowed and moved by means of natural peristalsis and gravity through the human gastrointestinal (GI) tract. The camera-integrated capsule allows for visualization of the small intestine, a region which was previously inaccessible to classical flexible endoscopy. As a diagnostic tool, it allows to localize the sources of bleedings in the middle part of the gastrointestinal tract and to identify diseases, such as inflammatory bowel disease (Crohn's disease), polyposis syndrome, and tumors. The screening and diagnostic efficacy of the WCE, especially in the stomach region, is hampered by a variety of technical challenges like the lack of active capsular position and orientation control. Therapeutic functionality is absent in most commercial capsules, due to constraints in capsular volume and energy storage. The possibility of using body-exogenous magnetic fields to guide, orient, power, and operate the capsule and its mechanisms has led to increasing research in Magnetically Guided Capsule Endoscopy (MGCE). This work shortly reviews the history and state-of-art in WCE technology. It highlights the magnetic technologies for advancing diagnostic and therapeutic functionalities of WCE. Not restricting itself to the GI tract, the review further investigates the technological developments in magnetically guided microrobots that can navigate through the various air- and fluid-filled lumina and cavities in the body for minimally invasive medicine. © 2017 American Association of Physicists in Medicine.
Klibansky, David; Rothstein, Richard I
2012-09-01
The increasing complexity of intralumenal and emerging translumenal endoscopic procedures has created an opportunity to apply robotics in endoscopy. Computer-assisted or direct-drive robotic technology allows the triangulation of flexible tools through telemanipulation. The creation of new flexible operative platforms, along with other emerging technology such as nanobots and steerable capsules, can be transformational for endoscopic procedures. In this review, we cover some background information on the use of robotics in surgery and endoscopy, and review the emerging literature on platforms, capsules, and mini-robotic units. The development of techniques in advanced intralumenal endoscopy (endoscopic mucosal resection and endoscopic submucosal dissection) and translumenal endoscopic procedures (NOTES) has generated a number of novel platforms, flexible tools, and devices that can apply robotic principles to endoscopy. The development of a fully flexible endoscopic surgical toolkit will enable increasingly advanced procedures to be performed through natural orifices. The application of platforms and new flexible tools to the areas of advanced endoscopy and NOTES heralds the opportunity to employ useful robotic technology. Following the examples of the utility of robotics from the field of laparoscopic surgery, we can anticipate the emerging role of robotic technology in endoscopy.
Wiarda, Bart M; Stolk, Mark; Heine, Dimitri G N; Mensink, Peter; Thieme, Mai E; Kuipers, Ernst J; Stoker, Jaap
2013-03-01
We aimed to prospectively determine patient burden and patient preference for magnetic resonance enteroclysis, capsule endoscopy and balloon-assisted enteroscopy in patients with suspected or known Crohn's disease (CD) or occult gastrointestinal bleeding (OGIB). Consecutive consenting patients with CD or OGIB underwent magnetic resonance enteroclysis, capsule endoscopy and balloon-assisted enteroscopy. Capsule endoscopy was only performed if magnetic resonance enteroclysis showed no high-grade small bowel stenosis. Patient preference and burden was evaluated by means of standardized questionnaires at five moments in time. From January 2007 until March 2009, 76 patients were included (M/F 31/45; mean age 46.9 years; range 20.0-78.4 years): 38 patients with OGIB and 38 with suspected or known CD. Seventeen patients did not undergo capsule endoscopy because of high-grade stenosis. Ninety-five percent (344/363) of the questionnaires were suitable for evaluation. Capsule endoscopy was significantly favored over magnetic resonance enteroclysis and balloon-assisted enteroscopy with respect to bowel preparation, swallowing of the capsule (compared to insertion of the tube/scope), burden of the entire examination, duration and accordance with the pre-study information. Capsule endoscopy and magnetic resonance enteroclysis were significantly preferred over balloon-assisted enteroscopy for clarity of explanation of the examination, and magnetic resonance enteroclysis was significantly preferred over balloon-assisted enteroscopy for bowel preparation, painfulness and burden of the entire examination. Balloon-assisted enteroscopy was significantly favored over magnetic resonance enteroclysis for insertion of the scope and procedure duration. Pre- and post-study the order of preference was capsule endoscopy, magnetic resonance enteroclysis and balloon-assisted enteroscopy. Capsule endoscopy was preferred to magnetic resonance enteroclysis and balloon-assisted enteroscopy; it also had the lowest burden. Magnetic resonance enteroclysis was preferred over balloon-assisted enteroscopy for clarity of explanation of the examination, bowel preparation, painfulness and burden of the entire examination, and balloon-assisted enteroscopy over magnetic resonance enteroclysis for scope insertion and study duration. © 2012 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.
Primary intestinal lymphangiectasia diagnosed by capsule endoscopy and double balloon enteroscopy
Oh, Tak Geun; Chung, Joo Won; Kim, Hee Man; Han, Seok-Joo; Lee, Jin Sung; Park, Jung Yeob; Song, Si Young
2011-01-01
Primary intestinal lymphangiectasia (PIL) is a rare disorder characterized by dilated intestinal lymphatics and the development of protein-losing enteropathy. Patients with PIL develop hypoalbuminemia, hypocalcemia, lymphopenia and hypogammaglobulinemia, and present with bilateral lower limb edema, fatigue, abdominal pain and diarrhea. Endoscopy reveals diffusely elongated, circumferential and polypoid mucosae covered with whitish enlarged villi, all of which indicate intestinal lymphangiectasia. Diagnosis is confirmed by characteristic tissue pathology, which includes dilated intestinal lymphatics with diffusely swollen mucosa and enlarged villi. The prevalence of PIL has increased since the introduction of capsule endoscopy. The etiology and prevalence of PIL remain unknown. Some studies have reported that several genes and regulatory molecules for lymphangiogenesis are related to PIL. We report the case of a patient with PIL involving the entire small bowel that was confirmed by capsule endoscopy and double-balloon enteroscopy-guided tissue pathology who carried a deletion on chromosome 4q25. The relationship between this deletion on chromosome 4 and PIL remains to be investigated. PMID:22110841
Capsule endoscopy in the diagnosis of Crohn's disease.
Niv, Yaron
2013-01-01
Crohn's disease is a chronic inflammatory disorder affecting any part of the gastrointestinal tract, but frequently involves the small and large bowel. Typical presenting symptoms include abdominal pain and diarrhea. Patients with this disorder may also have extraintestinal manifestations, including arthritis, uveitis, and skin lesions. The PillCam™SB capsule is an ingestible disposable video camera that transmits high quality images of the small intestinal mucosa. This enables the small intestine to be readily accessible to physicians investigating for the presence of small bowel disorders, such as Crohn's disease. Four meta-analyses have demonstrated that capsule endoscopy identifies Crohn's disease when other methods are not helpful. It should be noted that it is the best noninvasive procedure for assessing mucosal status, but is not superior to ileocolonoscopy, which remains the gold standard for assessment of ileocolonic disease. Mucosal healing along the small bowel can only be demonstrated by an endoscopic procedure such as capsule endoscopy. Achievement of long-term mucosal healing has been associated with a trend towards a decreased need for hospitalization and a decreased requirement for corticosteroid treatment in patients with Crohn's disease. Recently, we have developed and validated the Capsule Endoscopy Crohn's Disease Activity Index (also known as the Niv score) for Crohn's disease of the small bowel. The next step is to expand our score to the colon, and to determine the role and benefit of a capsule endoscopy activity score in patients suffering from Crohn's ileocolitis and/or colitis. This scoring system will also serve to improve our understanding of the impact of capsule endoscopy, and therefore treatment, on the immediate outcome of this disorder. As the best procedure available for assessing mucosal status, capsule endoscopy will provide important information about the course and outcome of Crohn's disease.
Rosa, Bruno; Pinho, Rolando; de Ferro, Susana Mão; Almeida, Nuno; Cotter, José; Saraiva, Miguel Mascarenhas
2016-01-01
The small bowel is affected in the vast majority of patients with Crohn's Disease (CD). Small bowel capsule endoscopy (SBCE) has a very high sensitivity for the detection of CD-related pathology, including early mucosal lesions and/or those located in the proximal segments of the small bowel, which is a major advantage when compared with other small bowel imaging modalities. The recent guidelines of European Society of Gastrointestinal Endoscopy (ESGE) and European Crohn's and Colitis Organisation (ECCO) advocate the use of validated endoscopic scoring indices for the classification of inflammatory activity in patients with CD undergoing SBCE, such as the Lewis Score or the Capsule Endoscopy Crohn's Disease Activity Index (CECDAI). These scores aim to standardize the description of lesions and capsule endoscopy reports, contributing to increase inter-observer agreement and enabling a stratification of the severity of the disease. On behalf of the Grupo de Estudos Português do Intestino Delgado (GEPID) - Portuguese Small Bowel Study Group, we aimed to summarize the general principles and clinical applications of current endoscopic scoring systems for SBCE in the setting of CD, covering the topic of suspected CD as well as the evaluation of disease extent (with potential prognostic and therapeutic impact), evaluation of mucosal healing in response to treatment and evaluation of post-surgical recurrence in patients with previously established diagnosis of CD.
Hooks, S Bennett; Rutland, Travis J; Di Palma, Jack A
2009-11-01
Lubiprostone, a selective activator of type 2 chloride channels, is approved for treatment of chronic idiopathic constipation and recently constipation-predominant irritable bowel syndrome. It has been suggested that lubiprostone has a prokinetic effect. This investigation was designed to evaluate lubiprostone as a preparation and propulsive agent for small-bowel capsule endoscopy. The PillCam Small Bowel capsule endoscopy system with the PillCam SB1 capsule and Rapid 5 software platform were used. The study was designed as a double-blind, placebo-controlled trial. Forty healthy adults. Gastric transit time (GTT), small-bowel transit time (SBTT), and adequacy of small-bowel cleansing preparation. The study subjects received 24 mug lubiprostone or placebo 30 minutes before PillCam capsule ingestion. Capsule endoscopy studies were read by 2 independent investigators unaware of the study medication received, and differences in interpretation were resolved by consensus. Anatomical landmarks were identified, and GTT and SBTT were calculated. Overall preparation quality assessment of the proximal, mid, and distal small bowel was determined by using a 4-step scale. The percentage of visualized bowel was determined by review of 10-minute video segments at 1-hour intervals after the capsule passed through the pylorus. In the lubiprostone group (n = 20), 2 subjects did not pass the capsule through the pylorus in the 8-hour battery life of the capsule. An additional 3 capsules did not pass into the colon. In the placebo group (n = 20), all capsules passed into the small bowel, but 1 did not pass into the colon. The subjects in whom the capsule did not pass into the small bowel were excluded from the small-bowel analysis. In the subjects in whom the capsule did reach the colon, the SBTT could not be calculated and they were excluded from SBTT analysis. The mean GTT in the lubiprostone group was 126 minutes and 43 minutes in the placebo group (P = .0095). The mean SBTT in the lubiprostone group was 188 minutes and 219 minutes in the placebo group (P = .130). The overall preparation assessment of the small bowel was not statistically significant between the 2 groups in the proximal, mid, or distal small bowel (proximal, P = .119; mid, P = .118; distal, P = .121). There was no significant difference in lubiprostone compared with placebo in the percentage of visualized small bowel. Some capsules did not leave the stomach or reach the cecum. Lubiprostone produced a significant increase in GTT but did not result in a significant decrease in SBTT compared with placebo. The administration of lubiprostone before capsule ingestion did not result in improved overall preparation of the small bowel for capsule endoscopy or increase the percentage of visualized small bowel. (The trial was registered at www.clinicaltrials.gov, identifier NCT00746395.).
Mylonaki, M; Fritscher-Ravens, A; Swain, P
2003-01-01
Background: The development of wireless capsule endoscopy allows painless imaging of the small intestine. Its clinical use is not yet defined. The aim of this study was to compare the clinical efficacy and technical performance of capsule endoscopy and push enteroscopy in a series of 50 patients with colonoscopy and gastroscopy negative gastrointestinal bleeding. Methods: A wireless capsule endoscope was used containing a CMOS colour video imager, transmitter, and batteries. Approximately 50 000 transmitted images are received by eight abdominal aerials and stored on a portable solid state recorder, which is carried on a belt. Push enteroscopy was performed using a 240 cm Olympus video enteroscope. Results: Studies in 14 healthy volunteers gave information on normal anatomical appearances and preparation. In 50 patients with gastrointestinal bleeding and negative colonoscopy and gastroscopy, push enteroscopy was compared with capsule endoscopy. A bleeding source was discovered in the small intestine in 34 of 50 patients (68%). These included angiodysplasia (16), focal fresh bleeding (eight), apthous ulceration suggestive of Crohn’s disease (three), tumour (two), Meckel’s diverticulum (two), ileal ulcer (one), jejunitis (one), and ulcer due to intussusception (one). One additional intestinal diagnosis was made by enteroscopy. The yield of push enteroscopy in evaluating obscure bleeding was 32% (16/50). The capsule identified significantly more small intestinal bleeding sources than push enteroscopy (p<0.05). Patients preferred capsule endoscopy to push enteroscopy (p<0.001). Conclusions: In this study capsule endoscopy was superior to push enteroscopy in the diagnosis of recurrent bleeding in patients who had a negative gastroscopy and colonoscopy. It was safe and well tolerated. PMID:12865269
Capsule endoscopy in the diagnosis of Crohn’s disease
Niv, Yaron
2013-01-01
Crohn’s disease is a chronic inflammatory disorder affecting any part of the gastrointestinal tract, but frequently involves the small and large bowel. Typical presenting symptoms include abdominal pain and diarrhea. Patients with this disorder may also have extraintestinal manifestations, including arthritis, uveitis, and skin lesions. The PillCam™SB capsule is an ingestible disposable video camera that transmits high quality images of the small intestinal mucosa. This enables the small intestine to be readily accessible to physicians investigating for the presence of small bowel disorders, such as Crohn’s disease. Four meta-analyses have demonstrated that capsule endoscopy identifies Crohn’s disease when other methods are not helpful. It should be noted that it is the best noninvasive procedure for assessing mucosal status, but is not superior to ileocolonoscopy, which remains the gold standard for assessment of ileocolonic disease. Mucosal healing along the small bowel can only be demonstrated by an endoscopic procedure such as capsule endoscopy. Achievement of long-term mucosal healing has been associated with a trend towards a decreased need for hospitalization and a decreased requirement for corticosteroid treatment in patients with Crohn’s disease. Recently, we have developed and validated the Capsule Endoscopy Crohn’s Disease Activity Index (also known as the Niv score) for Crohn’s disease of the small bowel. The next step is to expand our score to the colon, and to determine the role and benefit of a capsule endoscopy activity score in patients suffering from Crohn’s ileocolitis and/or colitis. This scoring system will also serve to improve our understanding of the impact of capsule endoscopy, and therefore treatment, on the immediate outcome of this disorder. As the best procedure available for assessing mucosal status, capsule endoscopy will provide important information about the course and outcome of Crohn’s disease. PMID:23818810
Identification of the duodenal papilla by colon capsule endoscope.
Karagiannis, S; Dücker, C; Dautel, P; Strubenhoff, J; Faiss, S
2010-07-01
The sensitivity of small-bowel capsule endoscopy in visualizing a single finding present in everyone, the duodenal papilla, is limited. In this retrospective case series study we evaluated whether the duodenal papilla can be better visualized by a capsule endoscope equipped with cameras on both ends. The recordings of 45 colonic capsule endoscopies (PillCam Colon) performed in a single tertiary center were re-evaluated seeking for the duodenal papilla. The two-hour sleeping period of the colon capsule endoscopy system led to the imaging of duodenum in 10 / 45 patients. The duodenal papilla was identified in 6 / 10 (60 %) patients while the number of frames where the papilla was clearly visualized ranged from 2 - 9. Consequently, a small-bowel capsule endoscope containing two cameras could better identify the duodenal papilla and theoretically other obscure areas of the small bowel, expanding its diagnostic accuracy.
Boal Carvalho, Pedro; Magalhães, Joana; Dias de Castro, Francisca; Gonçalves, Tiago Cúrdia; Rosa, Bruno; Moreira, Maria João; Cotter, José
2016-02-01
Small bowel capsule endoscopy represents the initial investigation for obscure gastrointestinal bleeding. Flexible spectral imaging colour enhancement (FICE) is a virtual chromoendoscopy technique designed to enhance mucosal lesions, available in different settings according to light wavelength-- FICE1, 2 and 3. To compare the diagnostic yield of FICE1 and white light during capsule endoscopy in patients with obscure gastrointestinal bleeding. Retrospective single-centre study including 60 consecutive patients referred for small bowel capsule endoscopy for obscure gastrointestinal bleeding. Endoscopies were independently reviewed in FICE1 and white light; findings were then reviewed by another researcher, establishing a gold standard. Diagnostic yield was defined as the presence of lesions with high bleeding potential (P2) angioectasias, ulcers or tumours. Diagnostic yield using FICE1 was significantly higher than white light (55% vs. 42%, p=0.021). A superior number of P2 lesions was detected with FICE1 (74 vs. 44, p=0.003), particularly angioectasias (54 vs. 26, p=0.002), but not ulcers or tumours. FICE1 was significantly superior to white light, resulting in a 13% improvement in diagnostic yield, and potentially bleeding lesions particularly angioectasias were more often observed. Our results support the use of FICE1 while reviewing small bowel capsule endoscopy for obscure gastrointestinal bleeding. Copyright © 2015 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Capsule endoscopy—A mechatronics perspective
NASA Astrophysics Data System (ADS)
Lin, Lin; Rasouli, Mahdi; Kencana, Andy Prima; Tan, Su Lim; Wong, Kai Juan; Ho, Khek Yu; Phee, Soo Jay
2011-03-01
The recent advances in integrated circuit technology, wireless communication, and sensor technology have opened the door for development of miniature medical devices that can be used for enhanced monitoring and treatment of medical conditions. Wireless capsule endoscopy is one of such medical devices that has gained significant attention during the past few years. It is envisaged that future wireless capsule endoscopies replace traditional endoscopy procedures by providing advanced functionalities such as active locomotion, body fluid/tissue sampling, and drug delivery. Development of energy-efficient miniaturized actuation mechanisms is a key step toward achieving this goal. Here, we review some of the actuators that could be integrated into future wireless capsules and discuss the existing challenges.
Wireless capsule endoscopy: perspectives beyond gastrointestinal bleeding.
Redondo-Cerezo, Eduardo; Sánchez-Capilla, Antonio Damián; De La Torre-Rubio, Paloma; De Teresa, Javier
2014-11-14
Wireless capsule endoscopy (CE) is a technology developed for the endoscopic exploration of the small bowel. The first capsule model was approved by the Food and Drug Administration in 2001, and its first and essential indication was occult gastrointestinal (GI) bleeding. Over subsequent years, this technology has been refined to provide superior resolution, increased battery life, and capabilities to view different parts of the GI tract. Indeed, cases for which CE proved useful have increased significantly over the last few years, with new indications for the small bowel and technical improvements that have expanded its use to other parts of the GI tract, including the esophagus and colon. The main challenges in the development of CE are new devices with the ability to provide therapy, air inflation for a better vision of the small bowel, biopsy sampling systems attached to the capsule and the possibility to guide and move the capsule with an external motion control. In this article we review the current and new indications of CE, and the evolving technological changes shaping this technology, which has a promising potential in the coming future of gastroenterology.
Video capsule endoscopy: Perspectives of a revolutionary technique
Bouchard, Simon; Ibrahim, Mostafa; Van Gossum, Andre
2014-01-01
Video capsule endoscopy (VCE) was launched in 2000 and has revolutionized direct endoscopic imaging of the gut. VCE is now a first-line procedure for exploring the small bowel in cases of obscure digestive bleeding and is also indicated in some patients with Crohn’s disease, celiac disease, and polyposis syndrome. A video capsule has also been designed for visualizing the esophagus in order to detect Barrett’s esophagus or esophageal varices. Different capsules are now available and differ with regard to dimensions, image acquisition rate, battery life, field of view, and possible optical enhancements. More recently, the use of VCE has been extended to exploring the colon. Within the last 5 years, tremendous developments have been made toward increasing the capabilities of the colon capsule. Although colon capsule cannot be proposed as a first-line colorectal cancer screening procedure, colon capsule may be used in patients with incomplete colonoscopy or in patients who are unwilling to undergo colonoscopy. In the near future, new technological developments will improve the diagnostic yield of VCE and broaden its therapeutic capabilities. PMID:25516644
Capsule endoscopy: The road ahead
Singeap, Ana-Maria; Stanciu, Carol; Trifan, Anca
2016-01-01
Since its introduction into clinical practice 15 years ago, capsule endoscopy (CE) has become the first-line investigation procedure in some small bowel pathologies, and more recently, dedicated esophageal and colon CE have expanded the fields of application to include the upper and lower gastrointestinal disorders. During this time, CE has become increasingly popular among gastroenterologists, with more than 2 million capsule examinations performed worldwide, and nearly 3000 PubMed-listed studies on its different aspects published. This huge interest in CE may be explained by its non-invasive nature, patient comfort, safety, and access to anatomical regions unattainable via conventional endoscopy. However, CE has several limitations which impede its wider clinical applications, including the lack of therapeutic capabilities, inability to obtain biopsies and control its locomotion. Several research groups are currently working to overcome these limitations, while novel devices able to control capsule movement, obtain high quality images, insufflate the gut lumen, perform chromoendoscopy, biopsy of suspect lesions, or even deliver targeted drugs directly to specific sites are under development. Overlooking current limitations, especially as some of them have already been successfully surmounted, and based on the tremendous progress in technology, it is expected that, by the end of next 15 years, CE able to perform both diagnostic and therapeutic procedures will remain the major form of digestive endoscopy. This review summarizes the literature that prognosticates about the future developments of CE. PMID:26755883
[Improvement of Digital Capsule Endoscopy System and Image Interpolation].
Zhao, Shaopeng; Yan, Guozheng; Liu, Gang; Kuang, Shuai
2016-01-01
Traditional capsule image collects and transmits analog image, with weak anti-interference ability, low frame rate, low resolution. This paper presents a new digital image capsule, which collects and transmits digital image, with frame rate up to 30 frames/sec and pixels resolution of 400 x 400. The image is compressed in the capsule, and is transmitted to the outside of the capsule for decompression and interpolation. A new type of interpolation algorithm is proposed, which is based on the relationship between the image planes, to obtain higher quality colour images. capsule endoscopy, digital image, SCCB protocol, image interpolation
International core curriculum for capsule endoscopy training courses.
Fernandez-Urien, Ignacio; Panter, Simon; Carretero, Cristina; Davison, Carolyn; Dray, Xavier; Fedorov, Evgeny; Makins, Richard; Mascarenhas, Miguel; McAlindon, Mark; McNamara, Deirdre; Palmer, Hansa; Rey, Jean Francoise; Saurin, Jean Christophe; Seitz, Uwe; Spada, Cristiano; Toth, Ervin; Wiedbrauck, Felix; Keuchel, Martin
2017-06-01
Capsule endoscopy (CE) has become a first-line noninvasive tool for visualisation of the small bowel (SB) and is being increasingly used for investigation of the colon. The European Society of Gastrointestinal Endoscopy (ESGE) guidelines have specified requirements for the clinical applications of CE. However, there are no standardized recommendations yet for CE training courses in Europe. The following suggestions in this curriculum are based on the experience of European CE training courses directors. It is suggested that 12 hours be dedicated for either a small bowel capsule endoscopy (SBCE) or a colon capsule endoscopy (CCE) course with 4 hours for an introductory CCE course delivered in conjunction with SBCE courses. SBCE courses should include state-of-the-art lectures on indications, contraindications, complications, patient management and hardware and software use. Procedural issues require approximately 2 hours. For CCE courses 2.5 hours for theoretical lessons and 3.5 hours for procedural issued are considered appropriate. Hands-on training on reading and interpretation of CE cases using a personal computer (PC) for 1 or 2 delegates is recommended for both SBCE and CCE courses. A total of 6 hours hands-on session- time should be allocated. Cases in a SBCE course should cover SB bleeding, inflammatory bowel diseases (IBD), tumors and variants of normal and cases with various types of polyps covered in CCE courses. Standardization of the description of findings and generation of high-quality reports should be essential parts of the training. Courses should be followed by an assessment of trainees' skills in order to certify readers' competency.
International core curriculum for capsule endoscopy training courses
Fernandez-Urien, Ignacio; Panter, Simon; Carretero, Cristina; Davison, Carolyn; Dray, Xavier; Fedorov, Evgeny; Makins, Richard; Mascarenhas, Miguel; McAlindon, Mark; McNamara, Deirdre; Palmer, Hansa; Rey, Jean Francoise; Saurin, Jean Christophe; Seitz, Uwe; Spada, Cristiano; Toth, Ervin; Wiedbrauck, Felix; Keuchel, Martin
2017-01-01
Capsule endoscopy (CE) has become a first-line noninvasive tool for visualisation of the small bowel (SB) and is being increasingly used for investigation of the colon. The European Society of Gastrointestinal Endoscopy (ESGE) guidelines have specified requirements for the clinical applications of CE. However, there are no standardized recommendations yet for CE training courses in Europe. The following suggestions in this curriculum are based on the experience of European CE training courses directors. It is suggested that 12 hours be dedicated for either a small bowel capsule endoscopy (SBCE) or a colon capsule endoscopy (CCE) course with 4 hours for an introductory CCE course delivered in conjunction with SBCE courses. SBCE courses should include state-of-the-art lectures on indications, contraindications, complications, patient management and hardware and software use. Procedural issues require approximately 2 hours. For CCE courses 2.5 hours for theoretical lessons and 3.5 hours for procedural issued are considered appropriate. Hands-on training on reading and interpretation of CE cases using a personal computer (PC) for 1 or 2 delegates is recommended for both SBCE and CCE courses. A total of 6 hours hands-on session- time should be allocated. Cases in a SBCE course should cover SB bleeding, inflammatory bowel diseases (IBD), tumors and variants of normal and cases with various types of polyps covered in CCE courses. Standardization of the description of findings and generation of high-quality reports should be essential parts of the training. Courses should be followed by an assessment of traineesʼ skills in order to certify readers’ competency. PMID:28596986
Ultrasound capsule endoscopy: sounding out the future
Stewart, Fraser; Lay, Holly; Cummins, Gerard; Newton, Ian P.; Desmulliez, Marc P. Y.; Steele, Robert J. C.; Näthke, Inke; Cochran, Sandy
2017-01-01
Video capsule endoscopy (VCE) has been of immense benefit in the diagnosis and management of gastrointestinal (GI) disorders since its introduction in 2001. However, it suffers from a number of well recognized deficiencies. Amongst these is the limited capability of white light imaging, which is restricted to analysis of the mucosal surface. Current capsule endoscopes are dependent on visual manifestation of disease and limited in regards to transmural imaging and detection of deeper pathology. Ultrasound capsule endoscopy (USCE) has the potential to overcome surface only imaging and provide transmural scans of the GI tract. The integration of high frequency microultrasound (µUS) into capsule endoscopy would allow high resolution transmural images and provide a means of both qualitative and quantitative assessment of the bowel wall. Quantitative ultrasound (QUS) can provide data in an objective and measurable manner, potentially reducing lengthy interpretation times by incorporation into an automated diagnostic process. The research described here is focused on the development of USCE and other complementary diagnostic and therapeutic modalities. Presently investigations have entered a preclinical phase with laboratory investigations running concurrently. PMID:28567381
Capsule endoscopy in Crohn’s disease: Are we seeing any better?
Hudesman, David; Mazurek, Jonathan; Swaminath, Arun
2014-01-01
Crohn’s disease (CD) is a complex, immune-mediated disorder that often requires a multi-modality approach for optimal diagnosis and management. While traditional methods include ileocolonoscopy and radiologic modalities, increasingly, capsule endoscopy (CE) has been incorporated into the algorithm for both the diagnosis and monitoring of CD. Multiple studies have examined the utility of this emerging technology in the management of CD, and have compared it to other available modalities. CE offers a noninvasive approach to evaluate areas of the small bowel that are difficult to reach with traditional endoscopy. Furthermore, CE maybe favored in specific sub segments of patients with inflammatory bowel disease (IBD), such as those with IBD unclassified (IBD-U), pediatric patients and patients with CD who have previously undergone surgery. PMID:25278698
Retained Wireless Capsule Endoscope in a Girl with suspected Crohn's Disease.
Herle, Koushik; Jehangir, Susan
2016-01-01
Wireless capsule endoscopy (WCE) is one of the great milestones in the field of gastroenterology. It is versatile in image acquisition, painless and can reach parts of the small bowel not amenable to conventional endoscopy. The commonest complication with WCE is retention of the capsule. We report a case of retained capsule in a child who was being investigated for obscure gastrointestinal bleeding (OGIB). Operative intervention was required for its retrieval after two weeks of expectant management.
The history of time for capsule endoscopy.
Adler, Samuel N
2017-05-01
Capsule endoscopy was conceived by inventive minds of good people. In the beginning there was a will to do something for medicine. The idea fomented after a discourse between the talented engineer with his physician friend. It took years to develop the concept. Then excellent engineers created de novo the necessary components to turn the capsule into a viable reality. The story is a tribute to human ingenuity.
Rahman, Merajur; Akerman, Stuart; DeVito, Bethany; Miller, Larry; Akerman, Meredith; Sultan, Keith
2015-05-14
To evaluate the completion rate and diagnostic yield of the PillCam SB2-ex in comparison to the PillCam SB2. Two hundred cases using the 8-h PillCam SB2 were retrospectively compared to 200 cases using the 12 h PillCam SB2-ex at a tertiary academic center. Endoscopically placed capsules were excluded from the study. Demographic information, indications for capsule endoscopy, capsule type, study length, completion of exam, clinically significant findings, timestamp of most distant finding, and significant findings beyond 8 h were recorded. The 8 and 12 h capsule groups were well matched respectively for both age (70.90 ± 14.19 vs 71.93 ± 13.80, P = 0.46) and gender (45.5% vs 48% male, P = 0.69). The most common indications for the procedure in both groups were anemia and obscure gastrointestinal bleeding. PillCam SB2-ex had a significantly higher completion rate than PillCam SB2 (88% vs 79.5%, P = 0.03). Overall, the diagnostic yield was greater for the 8 h capsule (48.5% for SB2 vs 35% for SB2-ex, P = 0.01). In 4/70 (5.7%) of abnormal SB2-ex exams the clinically significant finding was noted in the small bowel beyond the 8 h mark. In our study, we found the PillCam SB2-ex to have a significantly increased completion rate, though without any improvement in diagnostic yield compared to the PillCam SB2.
Swain, Paul; Toor, Arifa; Volke, Frank; Keller, Jutta; Gerber, Jeremy; Rabinovitz, Elisha; Rothstein, Richard I
2010-06-01
Remote manipulation of wireless capsule endoscopes might improve diagnostic accuracy and facilitate therapy. To test a new capsule-manipulation system. University hospital. A first-in-human study tested a new magnetic maneuverable wireless capsule in a volunteer. A wireless capsule endoscope was modified to include neodymium-iron-boron magnets. The capsule's magnetic switch was replaced with a thermal one and turned on by placing it in hot water. One imager was removed from the PillCam colon-based capsule, and the available space was used to house the magnets. A handheld external magnet was used to manipulate this capsule in the esophagus and stomach. The capsule was initiated by placing it in a microg of hot water. The capsule was swallowed and observed in the esophagus and stomach by using a gastroscope. Capsule images were viewed on a real-time viewer. The capsule was manipulated in the esophagus for 10 minutes. It was easy to make the capsule turn somersaults and to angulate at the cardioesophageal junction. In the stomach, it was easy to move the capsule back from the pylorus to the cardioesophageal junction and hold/spin the capsule at any position in the stomach. The capsule in the esophagus and stomach did not cause discomfort. Magnetic force varies with the fourth power of distance. This study suggests that remote manipulation of a capsule in the esophagus and stomach of a human is feasible and might enhance diagnostic endoscopy as well as enable therapeutic wireless capsule endoscopy. Copyright 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Capsule Endoscopy in the Assessment of Obscure Gastrointestinal Bleeding: An Evidence-Based Analysis
2015-01-01
Background Obscure gastrointestinal bleeding (OGIB) is defined as persistent or recurrent bleeding associated with negative findings on upper and lower gastrointestinal (GI) endoscopic evaluations. The diagnosis and management of patients with OGIB is particularly challenging because of the length and complex loops of the small intestine. Capsule endoscopy (CE) is 1 diagnostic modality that is used to determine the etiology of bleeding. Objectives The objective of this analysis was to review the diagnostic accuracy, safety, and impact on health outcomes of CE in patients with OGIB in comparison with other diagnostic modalities. Data Sources A literature search was performed using Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid Embase, the Wiley Cochrane Library, and the Centre for Reviews and Dissemination database, for studies published between 2007 and 2013. Review Methods Data on diagnostic accuracy, safety, and impact on health outcomes were abstracted from included studies. Quality of evidence was assessed using Grading of Recommendations Assessment, Development, and Evaluation (GRADE). Results The search yielded 1,189 citations, and 24 studies were included. Eight studies reported diagnostic accuracy comparing CE with other diagnostic modalities. Capsule endoscopy has a higher sensitivity and lower specificity than magnetic resonance enteroclysis, computed tomography, and push enteroscopy. Capsule endoscopy has a good safety profile with few adverse events, although comparative safety data with other diagnostic modalities are limited. Capsule endoscopy is associated with no difference in patient health-related outcomes such as rebleeding or follow-up treatment compared with push enteroscopy, small-bowel follow-through, and angiography. Limitations There was significant heterogeneity in estimates of diagnostic accuracy, which prohibited a statistical summary of findings. The analysis was also limited by the fact that there is no established reference standard to which the diagnostic accuracy of CE can be compared. Conclusions There is very-low-quality evidence that CE has a higher sensitivity but a lower specificity than other diagnostic modalities. Capsule endoscopy has few adverse events, with capsule retention being the most serious complication. Capsule endoscopy is perceived by patients as less painful and less burdensome compared with other modalities. There is low-quality evidence that patients who undergo CE have similar rates of rebleeding, further therapeutic interventions, and hospitalization compared with other diagnostic modalities. PMID:26357529
Historical analysis of experience with small bowel capsule endoscopy in a spanish tertiary hospital.
Egea Valenzuela, Juan; Carrilero Zaragoza, Gabriel; Iglesias Jorquera, Elena; Tomás Pujante, Paula; Alberca de Las Parras, Fernando; Carballo Álvarez, Fernando
2017-02-01
Capsule endoscopy was approved by the FDA in 2001. Gastrointestinal bleeding and inflammatory bowel disease are the main indications. It has been available in our hospital since 2004. We retrospectively analysed data from patients who underwent small bowel capsule endoscopy in our hospital from October 2004 to April 2015. Indications were divided into: Obscure gastrointestinal bleeding (occult and overt), inflammatory bowel disease, and other indications. Findings were divided into: Vascular lesions, inflammatory lesions, other lesions, normal studies, and inconclusive studies. A total of 1027 out of 1291 small bowel studies were included. Mean patient age was 56.45 years; 471 were men and 556 women. The most common lesion observed was angiectasia, as an isolated finding or associated with other lesions. Findings were significant in up to 80% of studies when the indication was gastrointestinal bleeding, but in only 50% of studies in inflammatory bowel disease. Diagnostic yield was low in the group «other indications». No major complications were reported. Small bowel capsule endoscopy has high diagnostic yield in patients with gastrointestinal bleeding, but yield is lower in patients with inflammatory bowel disease. Our experience shows that capsule endoscopy is a safe and useful tool for the diagnosis of small bowel disease. The diagnostic yield of the technique in inflammatory bowel disease must be improved. Copyright © 2016 Elsevier España, S.L.U., AEEH y AEG. All rights reserved.
A discrete-time localization method for capsule endoscopy based on on-board magnetic sensing
NASA Astrophysics Data System (ADS)
Salerno, Marco; Ciuti, Gastone; Lucarini, Gioia; Rizzo, Rocco; Valdastri, Pietro; Menciassi, Arianna; Landi, Alberto; Dario, Paolo
2012-01-01
Recent achievements in active capsule endoscopy have allowed controlled inspection of the bowel by magnetic guidance. Capsule localization represents an important enabling technology for such kinds of platforms. In this paper, the authors present a localization method, applied as first step in time-discrete capsule position detection, that is useful for establishing a magnetic link at the beginning of an endoscopic procedure or for re-linking the capsule in the case of loss due to locomotion. The novelty of this approach consists in using magnetic sensors on board the capsule whose output is combined with pre-calculated magnetic field analytical model solutions. A magnetic field triangulation algorithm is used for obtaining the position of the capsule inside the gastrointestinal tract. Experimental validation has demonstrated that the proposed procedure is stable, accurate and has a wide localization range in a volume of about 18 × 103 cm3. Position errors of 14 mm along the X direction, 11 mm along the Y direction and 19 mm along the Z direction were obtained in less than 27 s of elaboration time. The proposed approach, being compatible with magnetic fields used for locomotion, can be easily extended to other platforms for active capsule endoscopy.
Small bowel capsule endoscopy in 2007: Indications, risks and limitations
Rondonotti, Emanuele; Villa, Federica; Mulder, Chris JJ; Jacobs, Maarten AJM; de Franchis, Roberto
2007-01-01
Capsule endoscopy has revoluzionized the study of the small bowel by providing a reliable method to evaluate, endoscopically, the entire small bowel. In the last six years several papers have been published exploring the possible role of this examination in different clinical conditions. At the present time capsule endoscopy is generally recommended as a third examination, after negative bidirectional endoscopy, in patients with obscure gastrointestinal bleeding. A growing body of evidence suggests also an important role for this examination in other clinical conditions such as Crohn’s disease, celiac disease, small bowel polyposis syndromes or small bowel tumors. The main complication of this examination is the retention of the device at the site of a previously unknown small bowel stricture. However there are also some other open issues mainly due to technical limitations of this tool (which is not driven from remote control, is unable to take biopsies, to insufflate air, to suck fluids or debris and sometimes to correctly size and locate lesions).The recently developed double balloon enteroscope, owing to its capability to explore a large part of the small bowel and to take targeted biopsies, although being invasive and time consuming, can overcome some limitations of capsule endoscopy. At the present time, in the majority of clinical conditions (i.e. obscure GI bleeding), the winning strategy seems to be to couple these two techniques to explore the small bowel in a painless, safe and complete way (with capsule endoscopy) and to define and treat the lesions identified (with double balloon enteroscopy). PMID:18069752
Hu, Erzhong; Nosato, Hirokazu; Sakanashi, Hidenori; Murakawa, Masahiro
2013-01-01
Capsule endoscopy is a patient-friendly endoscopy broadly utilized in gastrointestinal examination. However, the efficacy of diagnosis is restricted by the large quantity of images. This paper presents a modified anomaly detection method, by which both known and unknown anomalies in capsule endoscopy images of small intestine are expected to be detected. To achieve this goal, this paper introduces feature extraction using a non-linear color conversion and Higher-order Local Auto Correlation (HLAC) Features, and makes use of image partition and subspace method for anomaly detection. Experiments are implemented among several major anomalies with combinations of proposed techniques. As the result, the proposed method achieved 91.7% and 100% detection accuracy for swelling and bleeding respectively, so that the effectiveness of proposed method is demonstrated.
In-to-out body path loss for wireless radio frequency capsule endoscopy in a human body.
Vermeeren, G; Tanghe, E; Thielens, A; Martens, L; Joseph, W
2016-08-01
Physical-layer characterization is important for design of in-to-out body communication for wireless body area networks (WBANs). This paper numerically investigates the path loss of an in-to-out body radio frequency (RF) wireless link between an endoscopy capsule and a receiver outside the body using a 3D electromagnetic solver. A spiral antenna in the endoscopy capsule is tuned to operate in the Medical Implant Communication Service (MICS) band at 402 MHz, accounting for the properties of the human body. The influence of misalignment, rotation of the capsule, and human body model are investigated. Semi-empirical path loss models for various homogeneous tissues and 3D realistic human body models are provided for manufacturers to evaluate the performance of in-to-out-body WBAN systems.
Bronchial Aspiration of Capsule Endoscope.
Buscot, Matthieu; Leroy, Sylvie; Pradelli, Johanna; Chaabane, Nouha; Hebuterne, Xavier; Marquette, Charles-Hugo; Filippi, Jerôme
2017-01-01
Capsule endoscope aspiration is an increasingly reported complication, potentially responsible for respiratory distress and asphyxia. This adverse event is primarily managed by rigid bronchoscopy when spontaneous expulsion does not occur. This complication is all the more detrimental to patients as it can delay or jeopardize further digestive exploration. We report direct repositioning of the capsule in the stomach at the same time as bronchoscopy, thus making second-line gastrointestinal endoscopy needless. © 2017 S. Karger AG, Basel.
Asymptomatic bronchial aspiration and prolonged retention of a capsule endoscope: a case report.
Pezzoli, Alessandro; Fusetti, Nadia; Carella, Alessandra; Gullini, Sergio
2011-08-02
Capsule endoscopy has, over the last few years, become a first-line test to visualize the mucosa of the small intestine. This technique is generally considered safe and does not cause discomfort for patients. However, although patients may have difficulty in swallowing the capsule, bronchial aspiration of a capsule endoscope is a very rare complication. We report the case of an 82-year-old man who experienced prolonged bronchial aspiration of a capsule endoscope without relevant symptoms, followed by a spontaneous return of the capsule to the gastrointestinal tract. An 82-year-old Caucasian man was referred to our unit from another local hospital to undergo capsule endoscopy. He swallowed the capsule without any apparent difficulties and did not show any overt symptoms. The following day, when we reviewed the capsule endoscopy images, we realized that the capsule was in the bronchial system and remained there for the duration of the study. An urgent X-ray of the chest confirmed the presence of the capsule in the left side of the bronchopulmonary tree. Two days later a repeat chest X-ray showed the capsule in the right bronchus. After two days the capsule was retrieved in the feces. Our patient remained asymptomatic during the entire admission period. Aspiration of a capsule endoscope is a rare complication; to the best of our knowledge this is the first reported case in which a capsule endoscope remained for six days in the bronchial system of a patient without causing airway compromise or pneumonitis and spontaneously returned to the gastrointestinal tract.
Zhou, Jieqiong; Tang, Xiaowei; Wang, Jing; Chen, Zhenyu; Wang, Xinying; Jiang, Bo
2017-08-01
Bowel preparation regimens for colon capsule endoscopy are not yet standardized since they are not well optimized. The aim of the present study was to evaluate the feasibility of a novel low-volume and sodium phosphate-free bowel preparation regimen for colon capsule endoscopy. A total of 31 patients were prospectively enrolled. In the novel regimen, on the day prior to examination, a low-fiber diet was permitted, 5 mg mosapride citrate was administered twice (1 h prior to lunch and supper) and 1 l polyethylene glycol was administered in the evening. On the day of the examination, an additional 1 l polyethylene glycol, 5 mg mosapride citrate and 200 mg simethicone were administered before capsule ingestion. Polyethylene glycol booster (0.5 l) was administered twice, at 1 and 4 h following capsule ingestion. Colon cleansing levels, ileocecal valve transit time and completion rate were evaluated. A total of 29 patients were included in the final analysis, 90% of whom achieved adequate preparation of the overall colon. Ileocecal valve transit time was 2.35±0.82 h and completion rate was 79.3%. The results revealed that the novel low-volume and sodium phosphate-free bowel preparation regimen for colon capsule endoscopy was feasible, with adequate colon cleansing and completion rates, and has the potential to be used as an alternative regimen.
Enteroscopy in the diagnosis and management of celiac disease.
Rondonotti, Emanuele; Villa, Federica; Saladino, Valeria; de Franchis, Roberto
2009-07-01
Esophagogastroduodenoscopy (EGD) with 3 to 6 biopsies in the descending duodenum is the gold standard for the diagnosis of celiac disease. At the time of the first diagnosis of celiac disease, an extensive evaluation of the small bowel is not recommended. However, video capsule endoscopy, because of its good sensitivity and specificity in recognizing the Endoscopic features of celiac disease, can be considered a valid alternative to EGD in patients unable or unwilling to undergo EGD with biopsies. Capsule endoscopy is also a possible option in selected cases with strong suspicion of celiac disease but negative first-line tests. In evaluating patients with refractory or complicated celiac disease, in whom a complete evaluation of the small bowel is mandatory (at least in refractory celiac disease type II patients) because of the possible presence of complications beyond the reach of conventional endoscopes, both capsule endoscopy and balloon-assisted enteroscopy have been found to be helpful. In these patients, capsule endoscopy offers several advantages: it is well tolerated, it allows inspection of the entire small bowel, and it is able to recognize subtle mucosal changes. However, in this setting, capsule endoscopy should ideally be coupled with imaging techniques that provide important information about the thickness of the wall of the intestine and about extraluminal abnormalities. Although deep enteroscopy (such as balloon enteroscopy) is expensive, time-consuming, and potentially risky in these frail patients, they may have a key role, because they make it possible to take tissue samples from deep in the small intestine.
Ingestible wireless capsules for enhanced diagnostic inspection of gastrointestinal tract
NASA Astrophysics Data System (ADS)
Rasouli, Mahdi; Kencana, Andy Prima; Huynh, Van An; Ting, Eng Kiat; Lai, Joshua Chong Yue; Wong, Kai Juan; Tan, Su Lim; Phee, Soo Jay
2011-03-01
Wireless capsule endoscopy has become a common procedure for diagnostic inspection of gastrointestinal tract. This method offers a less-invasive alternative to traditional endoscopy by eliminating uncomfortable procedures of the traditional endoscopy. Moreover, it provides the opportunity for exploring inaccessible areas of the small intestine. Current capsule endoscopes, however, move by peristalsis and are not capable of detailed and on-demand inspection of desired locations. Here, we propose and develop two wireless endoscopes with maneuverable vision systems to enhance diagnosis of gastrointestinal disorders. The vision systems in these capsules are equipped with mechanical actuators to adjust the position of the camera. This may help to cover larger areas of the digestive tract and investigate desired locations. The preliminary experimental results showed that the developed platform could successfully communicate with the external control unit via human body and adjust the position of camera to limited degrees.
Capsule endoscopy: Current practice and future directions
Hale, Melissa F; Sidhu, Reena; McAlindon, Mark E
2014-01-01
Capsule endoscopy (CE) has transformed investigation of the small bowel providing a non-invasive, well tolerated means of accurately visualising the distal duodenum, jejunum and ileum. Since the introduction of small bowel CE thirteen years ago a high volume of literature on indications, diagnostic yields and safety profile has been presented. Inclusion in national and international guidelines has placed small bowel capsule endoscopy at the forefront of investigation into suspected diseases of the small bowel. Most commonly, small bowel CE is used in patients with suspected bleeding or to identify evidence of active Crohn’s disease (CD) (in patients with or without a prior history of CD). Typically, CE is undertaken after upper and lower gastrointestinal flexible endoscopy has failed to identify a diagnosis. Small bowel radiology or a patency capsule test should be considered prior to CE in those at high risk of strictures (such as patients known to have CD or presenting with obstructive symptoms) to reduce the risk of capsule retention. CE also has a role in patients with coeliac disease, suspected small bowel tumours and other small bowel disorders. Since the advent of small bowel CE, dedicated oesophageal and colon capsule endoscopes have expanded the fields of application to include the investigation of upper and lower gastrointestinal disorders. Oesophageal CE may be used to diagnose oesophagitis, Barrett’s oesophagus and varices but reliability in identifying gastroduodenal pathology is unknown and it does not have biopsy capability. Colon CE provides an alternative to conventional colonoscopy for symptomatic patients, while a possible role in colorectal cancer screening is a fascinating prospect. Current research is already addressing the possibility of controlling capsule movement and developing capsules which allow tissue sampling and the administration of therapy. PMID:24976712
Nakamura, Masanao; Hirooka, Yoshiki; Yamamura, Takeshi; Miyahara, Ryoji; Watanabe, Osamu; Ando, Takafumi; Ohmiya, Naoki; Goto, Hidemi
2015-01-01
The Agile patency capsule (PC; Given Imaging Ltd, Yoqneam, Israel) is used as a dummy prior to capsule endoscopy (CE) to avoid retention of the CE capsule. However, impaction of the PC's inner radio frequency identification (RFID) tag in a stricture could cause small-bowel ileus. Recently, the RFID tag-less PC was introduced into clinical practice. Herein, we aimed to retrospectively evaluate the usefulness of the tag-less PC. Of 154 patients who were scheduled to undergo CE, 100 consecutive patients (65%) who underwent PC evaluation were enrolled in the present study. Primary study end point was the retention rate of the CE capsule after successful passage of the PC. Secondary end point was analysis of the significant factors affecting the passage of the PC. In total, 87 patients (87%) had bowel patency confirmed by PC evaluation. There was no capsule retention in any of these 87 patients during CE. Abnormal findings were obtained from 60 CE, and 41 patients received new or modified treatment. Multivariate analysis of factors related to the confirmation of patency demonstrated that stenosis on imaging was the most influential factor (P = 0.002, odds ratio 16.387). The results confirmed that passage of the PC depends on stenosis on imaging. Use of the tag-less PC confirmed gastrointestinal tract patency for most of the patients who did not have stenosis on imaging and allowed estimation of the patency for patients who did have stenosis on imaging. © 2014 The Authors. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.
Small intestinal model for electrically propelled capsule endoscopy
2011-01-01
The aim of this research is to propose a small intestine model for electrically propelled capsule endoscopy. The electrical stimulus can cause contraction of the small intestine and propel the capsule along the lumen. The proposed model considered the drag and friction from the small intestine using a thin walled model and Stokes' drag equation. Further, contraction force from the small intestine was modeled by using regression analysis. From the proposed model, the acceleration and velocity of various exterior shapes of capsule were calculated, and two exterior shapes of capsules were proposed based on the internal volume of the capsules. The proposed capsules were fabricated and animal experiments were conducted. One of the proposed capsules showed an average (SD) velocity in forward direction of 2.91 ± 0.99 mm/s and 2.23 ± 0.78 mm/s in the backward direction, which was 5.2 times faster than that obtained in previous research. The proposed model can predict locomotion of the capsule based on various exterior shapes of the capsule. PMID:22177218
Capsule endoscopy: in search of the ideal image.
Enns, Robert
2008-01-01
Capsule studies can be reviewed by varying rates and speeds; however, the presence of significant debris is frustrating to the reviewer much like the excessive stool that tends to hinder the progress of a colonoscopist. Numerous studies have been published in regards to the advantages of an ideal preparation in the setting of capsule endoscopy. This most recent study by Wei et al. is another study that has demonstrated that a colonic preparation, in this situation, combined with simethicone given just prior to the capsule study results in improved visibility of the mucosa. In theory, this will lead to an improved diagnostic ability to limit excessive reading duration.
A review of drug delivery systems for capsule endoscopy.
Munoz, Fredy; Alici, Gursel; Li, Weihua
2014-05-01
The development of a highly controllable drug delivery system (DDS) for capsule endoscopy has become an important field of research due to its promising applications in therapeutic treatment of diseases in the gastrointestinal (GI) tract and drug absorption studies. Several factors need to be considered to establish the minimum requirements for a functional DDS. Environmental factors of the GI tract and also pharmaceutical factors can help determine the requirements to be met by a DDS in an endoscopic capsule. In order to minimize the influence of such factors on the performance of an effective DDS, at least two mechanisms should be incorporated into a capsule endoscope: an anchoring mechanism to control the capsule position and a drug release mechanism to control variables such as the drug release rate, number of doses and amount of drug released. The implementation of such remotely actuated mechanisms is challenging due to several constraints, including the limited space available in a swallowable capsule endoscope and the delicate and complex environment within the GI tract. This paper presents a comprehensive overview of existing DDS. A comparison of such DDS for capsule endoscopy based on the minimum DDS requirements is presented and future work is also discussed. Copyright © 2013 Elsevier B.V. All rights reserved.
Capsule endoscopy of the future: What’s on the horizon?
Slawinski, Piotr R; Obstein, Keith L; Valdastri, Pietro
2015-01-01
Capsule endoscopes have evolved from passively moving diagnostic devices to actively moving systems with potential therapeutic capability. In this review, we will discuss the state of the art, define the current shortcomings of capsule endoscopy, and address research areas that aim to overcome said shortcomings. Developments in capsule mobility schemes are emphasized in this text, with magnetic actuation being the most promising endeavor. Research groups are working to integrate sensor data and fuse it with robotic control to outperform today’s standard invasive procedures, but in a less intrusive manner. With recent advances in areas such as mobility, drug delivery, and therapeutics, we foresee a translation of interventional capsule technology from the bench-top to the clinical setting within the next 10 years. PMID:26457013
Efficiency of bowel preparation for capsule endoscopy examination: a meta-analysis.
Niv, Yaron
2008-03-07
Good preparation before endoscopic procedures is essential for successful visualization. The small bowel is difficult to evaluate because of its length and complex configuration. A meta-analysis was conducted of studies comparing small bowel visualization by capsule endoscopy with and without preparation. Medical data bases were searched for all studies investigating the preparation for capsule endoscopy of the small bowel up to July 31, 2007. Studies that scored bowel cleanness and measured gastric and small bowel transit time and rate of cecum visualization were included. The primary endpoint was the quality of bowel visualization. The secondary endpoints were transit times and proportion of examinations that demonstrated the cecum, with and without preparation. Meta-analysis was performed with StatDirect Statistical software, version 2.6.1 (http://statsdirect.com). Eight studies met the inclusion criteria. Bowel visualization was scored as "good" in 78% of the examinations performed with preparation and 49% performed without (P<0.0001). There were no significant differences in transit times or in the proportion of examinations that demonstrated the cecum with and without preparation. Capsule endoscopy preparation improves the quality of small bowel visualization, but has no effect on transit times, or demonstration of the cecum.
Efficiency of bowel preparation for capsule endoscopy examination: A meta-analysis
Niv, Yaron
2008-01-01
Good preparation before endoscopic procedures is essential for successful visualization. The small bowel is difficult to evaluate because of its length and complex configuration. A meta-analysis was conducted of studies comparing small bowel visualization by capsule endoscopy with and without preparation. Medical data bases were searched for all studies investigating the preparation for capsule endoscopy of the small bowel up to July 31, 2007. Studies that scored bowel cleanness and measured gastric and small bowel transit time and rate of cecum visualization were included. The primary endpoint was the quality of bowel visualization. The secondary endpoints were transit times and proportion of examinations that demonstrated the cecum, with and without preparation. Meta-analysis was performed with StatDirect Statistical software, version 2.6.1 (http://statsdirect.com). Eight studies met the inclusion criteria. Bowel visualization was scored as “good” in 78% of the examinations performed with preparation and 49% performed without (P < 0.0001). There were no significant differences in transit times or in the proportion of examinations that demonstrated the cecum with and without preparation. Capsule endoscopy preparation improves the quality of small bowel visualization, but has no effect on transit times, or demonstration of the cecum. PMID:18322940
Spada, Cristiano; Riccioni, Maria Elena; Costamagna, Guido
2007-07-01
Small bowel capsule endoscopy represents a significant advance in the investigation of the small bowel, allowing direct visualization of this section of the gastrointestinal system. More recently, new video capsules have been released, specifically designed to investigate the esophagus and the colon. In June 2006, Given Imaging Ltd received marketing clearance from the US FDA for the Rapid Access Real-Time (RT) and Rapid Access software. The Rapid Access RT is a handheld device that enables real-time viewing during capsule endoscopy procedures. To date, the clinical benefits of this device are unknown as studies on the Rapid Access RT system have not yet been published. However, it appears that the Rapid Access RT system may reduce the examination and reading time, and may impact significantly in cases where it is important to know the precise localization of the capsule (during PillCam ESO ingestion procedures, PillCam Colon examinations or when delayed gastric transit is suspected) or in case of severe gastrointestinal bleeding (when a therapeutic procedure is required urgently).
Wireless communication link for capsule endoscope at 600 MHz.
Khaleghi, A; Balasingham, I
2015-01-01
Simulation of a wireless communication link for a capsule endoscopy is presented for monitoring of small intestine in humans. The realized communication link includes the transmitting capsule antenna, the outside body receiving antenna and the model of the human body. The capsule antenna is designed for operating at the frequency band of 600 MHz with an impedance bandwidth of 10 MHz and omnidirectional radiation pattern. The quality of the communication link is improved by using directive antenna outside body inside matching layer for electromagnetic wave tuning to the body. The outside body antenna has circular polarization that guaranteeing the communication link for different orientations of the capsule inside intestine. It is shown that the path loss for the capsule in 60 mm from the abdomen surface varies between 37-47 dB in relation to the antenna orientation. This link can establish high data rate wireless communications for capsule endoscopy.
A robust real-time abnormal region detection framework from capsule endoscopy images
NASA Astrophysics Data System (ADS)
Cheng, Yanfen; Liu, Xu; Li, Huiping
2009-02-01
In this paper we present a novel method to detect abnormal regions from capsule endoscopy images. Wireless Capsule Endoscopy (WCE) is a recent technology where a capsule with an embedded camera is swallowed by the patient to visualize the gastrointestinal tract. One challenge is one procedure of diagnosis will send out over 50,000 images, making physicians' reviewing process expensive. Physicians' reviewing process involves in identifying images containing abnormal regions (tumor, bleeding, etc) from this large number of image sequence. In this paper we construct a novel framework for robust and real-time abnormal region detection from large amount of capsule endoscopy images. The detected potential abnormal regions can be labeled out automatically to let physicians review further, therefore, reduce the overall reviewing process. In this paper we construct an abnormal region detection framework with the following advantages: 1) Trainable. Users can define and label any type of abnormal region they want to find; The abnormal regions, such as tumor, bleeding, etc., can be pre-defined and labeled using the graphical user interface tool we provided. 2) Efficient. Due to the large number of image data, the detection speed is very important. Our system can detect very efficiently at different scales due to the integral image features we used; 3) Robust. After feature selection we use a cascade of classifiers to further enforce the detection accuracy.
Small bowel involvement documented by capsule endoscopy in Churg-Strauss syndrome
Beye, Birane; Lesur, Gilles; Claude, Pierre; Martzolf, Lionel; Kieffer, Pierre; Sondag, Daniel
2015-01-01
Churg-Strauss syndrome is a small and medium vessel vasculitis and is also known as allergic granulomatous angiitis. Gastrointestinal involvement is common in patients with Churg-Strauss syndrome (20-50%). The most common symptoms are abdominal pain, diarrhoea and occasionally gastrointestinal bleeding and perforation. We present a case of Churg-Strauss syndrome with small bowel lesions documented by video capsule endoscopy. PMID:26664542
Small bowel involvement documented by capsule endoscopy in Churg-Strauss syndrome.
Beye, Birane; Lesur, Gilles; Claude, Pierre; Martzolf, Lionel; Kieffer, Pierre; Sondag, Daniel
2015-01-01
Churg-Strauss syndrome is a small and medium vessel vasculitis and is also known as allergic granulomatous angiitis. Gastrointestinal involvement is common in patients with Churg-Strauss syndrome (20-50%). The most common symptoms are abdominal pain, diarrhoea and occasionally gastrointestinal bleeding and perforation. We present a case of Churg-Strauss syndrome with small bowel lesions documented by video capsule endoscopy.
Bass, Lee M; Misiewicz, Lawrence
2012-11-01
Wireless capsule endoscopy (WCE) is an increasingly used procedure for visualization of the small intestine. One challenge in pediatric WCE is the placement of the capsule in a population unable to swallow it for a variety of reasons. Here we present a novel use of the real-time (RT) viewer in the endoscopic deployment of the capsule endoscope. We performed a retrospective chart review on all WCE completed at the Children's Memorial Hospital from February 2010 to May 2011. Following a diagnostic upper endoscopy, the RT viewer was attached to the capsule recorder and image was noted before insertion. The endoscope and AdvanCE capsule delivery device were slowly advanced into duodenum while maintaining visualization on the RT viewer. A total of 17 patients who underwent a WCE with endoscopic placement were identified. They ranged in ages from 2 to 19 years. Thirteen patients required endoscopic placement because of the inability to swallow the capsule, whereas 4 were placed during a scheduled procedure to take advantage of sedation and airway protection. All of the 17 patients had successful deployment of the capsule into the duodenal lumen. In each case, the endoscopist was able to confirm capsule location in duodenum during scope withdrawal. There was no evidence of iatrogenic trauma or bleeding in any patient. There were 5 incomplete studies, a completion rate consistent with that described in the literature. The use of the RT viewer for endoscopic deployment of WCE is an effective technique to improve visualization of capsule placement in the pediatric population.
Zhou, Teng; Han, Guoqiang; Li, Bing Nan; Lin, Zhizhe; Ciaccio, Edward J; Green, Peter H; Qin, Jing
2017-06-01
Celiac disease is one of the most common diseases in the world. Capsule endoscopy is an alternative way to visualize the entire small intestine without invasiveness to the patient. It is useful to characterize celiac disease, but hours are need to manually analyze the retrospective data of a single patient. Computer-aided quantitative analysis by a deep learning method helps in alleviating the workload during analysis of the retrospective videos. Capsule endoscopy clips from 6 celiac disease patients and 5 controls were preprocessed for training. The frames with a large field of opaque extraluminal fluid or air bubbles were removed automatically by using a pre-selection algorithm. Then the frames were cropped and the intensity was corrected prior to frame rotation in the proposed new method. The GoogLeNet is trained with these frames. Then, the clips of capsule endoscopy from 5 additional celiac disease patients and 5 additional control patients are used for testing. The trained GoogLeNet was able to distinguish the frames from capsule endoscopy clips of celiac disease patients vs controls. Quantitative measurement with evaluation of the confidence was developed to assess the severity level of pathology in the subjects. Relying on the evaluation confidence, the GoogLeNet achieved 100% sensitivity and specificity for the testing set. The t-test confirmed the evaluation confidence is significant to distinguish celiac disease patients from controls. Furthermore, it is found that the evaluation confidence may also relate to the severity level of small bowel mucosal lesions. A deep convolutional neural network was established for quantitative measurement of the existence and degree of pathology throughout the small intestine, which may improve computer-aided clinical techniques to assess mucosal atrophy and other etiologies in real-time with videocapsule endoscopy. Copyright © 2017 Elsevier Ltd. All rights reserved.
Guidelines for Bowel Preparation before Video Capsule Endoscopy
Song, Hyun Joo; Do, Jae Hyuk; Cha, In Hye; Yang, Chang Hun; Choi, Myung-Gyu; Jeen, Yoon Tae; Kim, Hyun Jung
2013-01-01
The preparation for video capsule endoscopy (VCE) of the bowel suggested by manufacturers of capsule endoscopy systems consists only of a clear liquid diet and an 8-hour fast. While there is evidence for a benefit from bowel preparation for VCE, so far there is no domestic consensus on the preparation regimen in Korea. Therefore, we performed this study to recommend guidelines for bowel preparation before VCE. The guidelines on VCE were developed by the Korean Gut Image Study Group, part of the Korean Society of Gastrointestinal Endoscopy. Four key questions were selected. According to our guidelines, bowel preparation with polyethylene glycol (PEG) solution enhances small bowel visualization quality (SBVQ) and diagnostic yield (DY), but it has no effect on cecal completion rate (CR). Bowel preparation with 2 L of PEG solution is similar to that with 4 L of PEG in terms of the SBVQ, DY, and CR of VCE. Bowel preparation with fasting or PEG solution combined with simethicone enhances the SBVQ, but it does not affect the CR of VCE. Bowel preparation with prokinetics does not enhance the SBVQ, DY, or CR of VCE. PMID:23614124
NASA Astrophysics Data System (ADS)
Dong, Jing; Gora, Michalina J.; Reddy, Rohith; Trasischker, Wolfgang; Poupart, Oriane; Lu, Weina; Carruth, Robert W.; Grant, Catriona N.; Soomro, Amna R.; Tiernan, Aubrey R.; Rosenberg, Mireille; Nishioka, Norman S.; Tearney, Guillermo J.
2016-03-01
While endoscopy is the most commonly used modality for diagnosing upper GI tract disease, this procedure usually requires patient sedation that increases cost and mandates its operation in specialized settings. In addition, endoscopy only visualizes tissue superfically at the macroscopic scale, which is problematic for many diseases that manifest below the surface at a microscopic scale. Our lab has previously developed technology termed tethered capsule OCT endomicroscopy (TCE) to overcome these diagnostic limitations of endoscopy. The TCE device is a swallowable capsule that contains optomechanical components that circumferentially scan the OCT beam inside the body as the pill traverses the organ via peristalsis. While we have successfully imaged ~100 patients with the TCE device, the optics of our current device have many elements and are complex, comprising a glass ferrule, optical fiber, glass spacer, GRIN lens and prism. As we scale up manufacturing of this device for clinical translation, we must decrease the cost and improve the manufacturability of the capsule's optical configuration. In this abstract, we report on the design and development of simplificed TCE optics that replace the GRIN lens-based configuration with an angle-polished ball lens design. The new optics include a single mode optical fiber, a glass spacer and an angle polished ball lens, that are all fusion spliced together. The ball lens capsule has resolutions that are comparable with those of our previous GRIN lens configuration (30µm (lateral) × 7 µm (axial)). Results in human subjects show that OCT-based TCE using the ball lens not only provides rapid, high quality microstructural images of upper GI tract, but also makes it possible to implement this technology inexpensively and on a larger scale.
Advanced Image Enhancement Method for Distant Vessels and Structures in Capsule Endoscopy
Pedersen, Marius
2017-01-01
This paper proposes an advanced method for contrast enhancement of capsule endoscopic images, with the main objective to obtain sufficient information about the vessels and structures in more distant (or darker) parts of capsule endoscopic images. The proposed method (PM) combines two algorithms for the enhancement of darker and brighter areas of capsule endoscopic images, respectively. The half-unit weighted-bilinear algorithm (HWB) proposed in our previous work is used to enhance darker areas according to the darker map content of its HSV's component V. Enhancement of brighter areas is achieved thanks to the novel threshold weighted-bilinear algorithm (TWB) developed to avoid overexposure and enlargement of specular highlight spots while preserving the hue, in such areas. The TWB performs enhancement operations following a gradual increment of the brightness of the brighter map content of its HSV's component V. In other words, the TWB decreases its averaged weights as the intensity content of the component V increases. Extensive experimental demonstrations were conducted, and, based on evaluation of the reference and PM enhanced images, a gastroenterologist (Ø.H.) concluded that the PM enhanced images were the best ones based on the information about the vessels, contrast in the images, and the view or visibility of the structures in more distant parts of the capsule endoscopy images. PMID:29225668
Half-unit weighted bilinear algorithm for image contrast enhancement in capsule endoscopy
NASA Astrophysics Data System (ADS)
Rukundo, Olivier
2018-04-01
This paper proposes a novel enhancement method based exclusively on the bilinear interpolation algorithm for capsule endoscopy images. The proposed method does not convert the original RBG image components to HSV or any other color space or model; instead, it processes directly RGB components. In each component, a group of four adjacent pixels and half-unit weight in the bilinear weighting function are used to calculate the average pixel value, identical for each pixel in that particular group. After calculations, groups of identical pixels are overlapped successively in horizontal and vertical directions to achieve a preliminary-enhanced image. The final-enhanced image is achieved by halving the sum of the original and preliminary-enhanced image pixels. Quantitative and qualitative experiments were conducted focusing on pairwise comparisons between original and enhanced images. Final-enhanced images have generally the best diagnostic quality and gave more details about the visibility of vessels and structures in capsule endoscopy images.
Fang, You-Hong; Zhang, Bing-Ling; Wu, Jia-Guo; Chen, Chun-Xiao
2007-01-01
Intestinal lymphangiectasia (IL) is a rare disease characterized by dilated lymphatic vessles in the intestinal wall and small bowel mesentery which induce loss of protein and lymphocytes into bowel lumen. Because it most often occurs in the intestine and cannot be detected by upper gastroendoscopy or colonoscopy, and the value of common image examinations such as X-ray and computerized tomography (CT) are limited, the diagnosis of IL is difficult, usually needing the help of surgery. Capsule endoscopy is useful in diagnosing intestinal diseases, such as IL. We here report a case of IL in a female patient who was admitted for the complaint of recurrent edema accompanied with diarrhea and abdominal pain over the last twenty years, and aggravated ten days ago. She was diagnosed by M2A capsule endoscopy as a primary IL and confirmed by surgical and pathological examination. PMID:17465517
Fang, You-Hong; Zhang, Bing-Ling; Wu, Jia-Guo; Chen, Chun-Xiao
2007-04-21
Intestinal lymphangiectasia (IL) is a rare disease characterized by dilated lymphatic vessles in the intestinal wall and small bowel mesentery which induce loss of protein and lymphocytes into bowel lumen. Because it most often occurs in the intestine and cannot be detected by upper gastroendoscopy or colonoscopy, and the value of common image examinations such as X-ray and computerized tomography (CT) are limited, the diagnosis of IL is difficult, usually needing the help of surgery. Capsule endoscopy is useful in diagnosing intestinal diseases, such as IL. We here report a case of IL in a female patient who was admitted for the complaint of recurrent edema accompanied with diarrhea and abdominal pain over the last twenty years, and aggravated ten days ago. She was diagnosed by M2A capsule endoscopy as a primary IL and confirmed by surgical and pathological examination.
Contraindications for video capsule endoscopy
Bandorski, Dirk; Kurniawan, Niehls; Baltes, Peter; Hoeltgen, Reinhard; Hecker, Matthias; Stunder, Dominik; Keuchel, Martin
2016-01-01
Video capsule endoscopy (VCE) has been applied in the last 15 years in an increasing field of applications. Although many contraindications have been put into perspective, some precautions still have to be considered. Known stenosis of the gastrointestinal tract is a clear contraindication for VCE unless surgery is already scheduled or at least has been considered as an optional treatment modality. In patients with a higher incidence of stenosis, as in an established diagnosis of Crohn’s disease, clinical signs of obstruction, prior radiation or surgical small bowel resection, a preceding test with the self-dissolving patency capsule can override this contraindication. Endoscopic placement of the capsule should be considered in patients with swallowing disorders to avoid aspiration. Esophageal or gastric motility disorders may require endoscopic capsule transport or application of prokinetics if the real-time viewer proofs delayed transit. In pregnant women, VCE should be restricted to urgent cases where diagnosis cannot be postponed after delivery, as data on safety are missing. There is theoretical and clinical evidence that patients with implanted cardiac devices such as a pacemaker, cardioverters or left heart assist devices, can safely undergo VCE in spite of still existing contraindication by manufacturers. Children from the age of 2 years have safely undergone VCE. Although video capsules are not proven safe with magnetic resonance imaging (MRI), first single cases of patients incidentally undergoing MRI with an incorporated capsule have been reported, showing susceptibility artifacts but no signs of clinical harm. PMID:28018097
Emerging Issues and Future Developments in Capsule Endoscopy
Slawinski, Piotr R.; Obstein, Keith L.; Valdastri, Pietro
2015-01-01
Capsule endoscopy (CE) has transformed from a research venture into a widely used clinical tool and the primary means for diagnosing small bowel pathology. These orally administered capsules traverse passively through the gastrointestinal tract via peristalsis and are used in the esophagus, stomach, small bowel, and colon. The primary focus of CE research in recent years has been enabling active CE manipulation and extension of the technology to therapeutic functionality; thus, widening the scope of the procedure. This review outlines clinical standards of the technology as well as recent advances in CE research. Clinical capsule applications are discussed with respect to each portion of the gastrointestinal tract. Promising research efforts are presented with an emphasis on enabling active capsule locomotion. The presented studies suggest, in particular, that the most viable solution for active capsule manipulation is actuation of a capsule via exterior permanent magnet held by a robot. Developing capsule procedures adhering to current healthcare standards, such as enabling a tool channel or irrigation in a therapeutic device, is a vital phase in the adaptation of CE in the clinical setting. PMID:26028956
Capsule Endoscope Aspiration after Repeated Attempts for Ingesting a Patency Capsule
Mannami, Tomohiko; Ikeda, Genyo; Seno, Satoru; Sonobe, Hiroshi; Fujiwara, Nobukiyo; Komoda, Minori; Edahiro, Satoru; Ohtawa, Yasuyuki; Fujimoto, Yoshimi; Sato, Naohiro; Kambara, Takeshi; Waku, Toshihiko
2015-01-01
Capsule endoscope aspiration into the respiratory tract is a rare complication of capsule endoscopy. Despite the potential seriousness of this complication, no accepted methods exist to accurately predict and therefore prevent it. We describe the case of an 85-year-old male who presented for evaluation of iron deficiency anemia. He complained of dysphagia while ingesting a patency capsule, with several attempts over a period of 5 min before he was successful. Five days later, he underwent capsule endoscopy, where he experienced similar symptoms in swallowing the capsule. The rest of the examination proceeded uneventfully. On reviewing the captured images, the capsule endoscope was revealed to be aspirated, remaining in the respiratory tract for approximately 220 s before images of the esophagus and stomach appeared. To our knowledge, this is the first documented case of a patient who experienced capsule endoscope aspiration after ingestion of a patency capsule. This case suggests that repeated attempts required for ingesting the patency capsule can predict capsule endoscope aspiration. We presume that paying sufficient attention to the symptoms of a patient who ingests a patency capsule could help us prevent serious complications such as aspiration of the capsule endoscope. In addition, this experience implies the potential risk for ingesting the patency capsule. We must be aware that the patency capsule could also be aspirated and there may be more unrecognized aspiration cases. PMID:26600772
Capsule Endoscope Aspiration after Repeated Attempts for Ingesting a Patency Capsule.
Mannami, Tomohiko; Ikeda, Genyo; Seno, Satoru; Sonobe, Hiroshi; Fujiwara, Nobukiyo; Komoda, Minori; Edahiro, Satoru; Ohtawa, Yasuyuki; Fujimoto, Yoshimi; Sato, Naohiro; Kambara, Takeshi; Waku, Toshihiko
2015-01-01
Capsule endoscope aspiration into the respiratory tract is a rare complication of capsule endoscopy. Despite the potential seriousness of this complication, no accepted methods exist to accurately predict and therefore prevent it. We describe the case of an 85-year-old male who presented for evaluation of iron deficiency anemia. He complained of dysphagia while ingesting a patency capsule, with several attempts over a period of 5 min before he was successful. Five days later, he underwent capsule endoscopy, where he experienced similar symptoms in swallowing the capsule. The rest of the examination proceeded uneventfully. On reviewing the captured images, the capsule endoscope was revealed to be aspirated, remaining in the respiratory tract for approximately 220 s before images of the esophagus and stomach appeared. To our knowledge, this is the first documented case of a patient who experienced capsule endoscope aspiration after ingestion of a patency capsule. This case suggests that repeated attempts required for ingesting the patency capsule can predict capsule endoscope aspiration. We presume that paying sufficient attention to the symptoms of a patient who ingests a patency capsule could help us prevent serious complications such as aspiration of the capsule endoscope. In addition, this experience implies the potential risk for ingesting the patency capsule. We must be aware that the patency capsule could also be aspirated and there may be more unrecognized aspiration cases.
Chromoendoscopy in magnetically guided capsule endoscopy
2013-01-01
Background Diagnosis of intestinal metaplasia and dysplasia via conventional endoscopy is characterized by low interobserver agreement and poor correlation with histopathologic findings. Chromoendoscopy significantly enhances the visibility of mucosa irregularities, like metaplasia and dysplasia mucosa. Magnetically guided capsule endoscopy (MGCE) offers an alternative technology for upper GI examination. We expect the difficulties of diagnosis of neoplasm in conventional endoscopy to transfer to MGCE. Thus, we aim to chart a path for the application of chromoendoscopy on MGCE via an ex-vivo animal study. Methods We propose a modified preparation protocol which adds a staining step to the existing MGCE preparation protocol. An optimal staining concentration is quantitatively determined for different stain types and pathologies. To that end 190 pig stomach tissue samples with and without lesion imitations were stained with different dye concentrations. Quantitative visual criteria are introduced to measure the quality of the staining with respect to mucosa and lesion visibility. Thusly determined optimal concentrations are tested in an ex-vivo pig stomach experiment under magnetic guidance of an endoscopic capsule with the modified protocol. Results We found that the proposed protocol modification does not impact the visibility in the stomach or steerability of the endoscopy capsule. An average optimal staining concentration for the proposed protocol was found at 0.4% for Methylene blue and Indigo carmine. The lesion visibility is improved using the previously obtained optimal dye concentration. Conclusions We conclude that chromoendoscopy may be applied in MGCE and improves mucosa and lesion visibility. Systematic evaluation provides important information on appropriate staining concentration. However, further animal and human in-vivo studies are necessary. PMID:23758801
Capsule Endoscopy in Patients with Implantable Electromedical Devices is Safe
Harris, Lucinda A.; Hansel, Stephanie L.; Rajan, Elizabeth; Srivathsan, Komandoor; Rea, Robert; Crowell, Michael D.; Fleischer, David E.; Pasha, Shabana F.; Gurudu, Suryakanth R.; Heigh, Russell I.; Shiff, Arthur D.; Post, Janice K.; Leighton, Jonathan A.
2013-01-01
Background and Study Aims. The presence of an implantable electromechanical cardiac device (IED) has long been considered a relative contraindication to the performance of video capsule endoscopy (CE). The primary aim of this study was to evaluate the safety of CE in patients with IEDs. A secondary purpose was to determine whether IEDs have any impact on images captured by CE. Patients and Methods. A retrospective chart review of all patients who had a capsule endoscopy at Mayo Clinic in Scottsdale, AZ, USA, or Rochester, MN, USA, (January 2002 to June 2010) was performed to identify CE studies done on patients with IEDs. One hundred and eighteen capsule studies performed in 108 patients with IEDs were identified and reviewed for demographic data, method of preparation, and study data. Results. The most common indications for CE were obscure gastrointestinal bleeding (77%), anemia (14%), abdominal pain (5%), celiac disease (2%), diarrhea (1%), and Crohn's disease (1%). Postprocedure assessments did not reveal any detectable alteration on the function of the IED. One patient with an ICD had a 25-minute loss of capsule imaging due to recorder defect. Two patients with LVADs had interference with capsule image acquisition. Conclusions. CE did not interfere with IED function, including PM, ICD, and/or LVAD and thus appears safe. Additionally, PM and ICD do not appear to interfere with image acquisition but LVAD may interfere with capsule images and require that capsule leads be positioned as far away as possible from the IED to assure reliable image acquisition. PMID:23710168
Khan, Tareq H.; Wahid, Khan A.
2014-01-01
In this paper, a new low complexity and lossless image compression system for capsule endoscopy (CE) is presented. The compressor consists of a low-cost YEF color space converter and variable-length predictive with a combination of Golomb-Rice and unary encoding. All these components have been heavily optimized for low-power and low-cost and lossless in nature. As a result, the entire compression system does not incur any loss of image information. Unlike transform based algorithms, the compressor can be interfaced with commercial image sensors which send pixel data in raster-scan fashion that eliminates the need of having large buffer memory. The compression algorithm is capable to work with white light imaging (WLI) and narrow band imaging (NBI) with average compression ratio of 78% and 84% respectively. Finally, a complete capsule endoscopy system is developed on a single, low-power, 65-nm field programmable gate arrays (FPGA) chip. The prototype is developed using circular PCBs having a diameter of 16 mm. Several in-vivo and ex-vivo trials using pig's intestine have been conducted using the prototype to validate the performance of the proposed lossless compression algorithm. The results show that, compared with all other existing works, the proposed algorithm offers a solution to wireless capsule endoscopy with lossless and yet acceptable level of compression. PMID:25375753
Wang, Xingying; Seetohul, Vipin; Chen, Ruimin; Zhang, Zhiqiang; Qian, Ming; Shi, Zhehao; Yang, Ge; Mu, Peitian; Wang, Congzhi; Huang, Zhihong; Zhou, Qifa; Zheng, Hairong; Cochran, Sandy; Qiu, Weibao
2017-09-01
Wireless capsule endoscopy has opened a new era by enabling remote diagnostic assessment of the gastrointestinal tract in a painless procedure. Video capsule endoscopy is currently commercially available worldwide. However, it is limited to visualization of superficial tissue. Ultrasound (US) imaging is a complementary solution as it is capable of acquiring transmural information from the tissue wall. This paper presents a mechanical scanning device incorporating a high-frequency transducer specifically as a proof of concept for US capsule endoscopy (USCE), providing information that may usefully assist future research. A rotary solenoid-coil-based motor was employed to rotate the US transducer with sectional electronic control. A set of gears was used to convert the sectional rotation to circular rotation. A single-element focused US transducer with 39-MHz center frequency was used for high-resolution US imaging, connected to an imaging platform for pulse generation and image processing. Key parameters of US imaging for USCE applications were evaluated. Wire phantom imaging and tissue phantom imaging have been conducted to evaluate the performance of the proposed method. A porcine small intestine specimen was also used for imaging evaluation in vitro. Test results demonstrate that the proposed device and rotation mechanism are able to offer good image resolution ( [Formula: see text]) of the lumen wall, and they, therefore, offer a viable basis for the fabrication of a USCE device.
Matsuura, Mizue; Inamori, Masahiko; Endo, Hiroki; Matsuura, Tetsuya; Kanoshima, Kenji; Inoh, Yumi; Fujita, Yuji; Umezawa, Shotaro; Fuyuki, Akiko; Uchiyama, Shiori; Higurashi, Takuma; Ohkubo, Hidenori; Sakai, Eiji; Iida, Hiroshi; Nonaka, Takashi; Futagami, Seiji; Kusakabe, Akihiko; Maeda, Shin; Nakajima, Atsushi
2014-01-01
The aim of this study was to investigate the usefulness of lubiprostone for bowel preparation and as a propulsive agent in small bowel endoscopy. Six healthy male volunteers participated in this randomized, 3-way crossover study. The subjects received a 24 μg tablet of lubiprostone 60 minutes prior to the capsule ingestion for capsule endoscopy (CE) and a placebo tablet 30 minutes before the capsule ingestion (L-P regimen), a placebo tablet 60 minutes prior to CE and a 24 μg tablet of lubiprostone 30 minutes prior to CE (P-L regimen), or a placebo tablet 60 minutes prior to r CE and a placebo tablet again 30 minutes prior to CE (P-P regimen). The quality of the capsule endoscopic images and the amount of water in the small bowel were assessed on 5-point scale. The median SBTT was 178.5 (117-407) minutes in the P-P regimen, 122.5 (27-282) minutes in the L-P regimen, and 110.5 (11-331) minutes in the P-L regimen (P = 0.042). This study showed that the use of lubiprostone significantly decreased the SBTT. We also confirmed that lubiprostone was effective for inducing water secretion into the small bowel during CE.
Xiao Jia; Meng, Max Q-H
2017-07-01
Gastrointestinal (GI) bleeding detection plays an essential role in wireless capsule endoscopy (WCE) examination. In this paper, we present a new approach for WCE bleeding detection that combines handcrafted (HC) features and convolutional neural network (CNN) features. Compared with our previous work, a smaller-scale CNN architecture is constructed to lower the computational cost. In experiments, we show that the proposed strategy is highly capable when training data is limited, and yields comparable or better results than the latest methods.
On-the-fly detection of images with gastritis aspects in magnetically guided capsule endoscopy
NASA Astrophysics Data System (ADS)
Mewes, P. W.; Neumann, D.; Juloski, A. L.; Angelopoulou, E.; Hornegger, J.
2011-03-01
Capsule Endoscopy (CE) was introduced in 2000 and has since become an established diagnostic procedure for the small bowel, colon and esophagus. For the CE examination the patient swallows the capsule, which then travels through the gastrointestinal tract under the influence of the peristaltic movements. CE is not indicated for stomach examination, as the capsule movements can not be controlled from the outside and the entire surface of the stomach can not be reliably covered. Magnetically-guided capsule endoscopy (MGCE) was introduced in 2010. For the MGCE procedure the stomach is filled with water and the capsule is navigated from the outside using an external magnetic field. During the examination the operator can control the motion of the capsule in order to obtain a sufficient number of stomach-surface images with diagnostic value. The quality of the examination depends on the skill of the operator and his ability to detect aspects of interest in real time. We present a novel computer-assisted diagnostic-procedure (CADP) algorithm for indicating gastritis pathologies in the stomach during the examination. Our algorithm is based on pre-processing methods and feature vectors that are suitably chosen for the challenges of the MGCE imaging (suspended particles, bubbles, lighting). An image is classified using an ada-boost trained classifier. For the classifier training, a number of possible features were investigated. Statistical evaluation was conducted to identify relevant features with discriminative potential. The proposed algorithm was tested on 12 video sequences stemming from 6 volunteers. A mean detection rate of 91.17% was achieved during leave-one out cross-validation.
Figueiredo, Pedro; Almeida, Nuno; Lopes, Sandra; Duque, Gabriela; Freire, Paulo; Lérias, Clotilde; Gouveia, Hermano; Sofia, Carlos
2010-01-01
The aim of this work was to assess the value of capsule enteroscopy in the diagnosis of patients with suspected Crohn's Disease (CD). Methods. This was a retrospective study in a single tertiary care centre involving patients undergoing capsule enteroscopy for suspected CD. Patients taking nonsteroidal anti inflammatory drugs during the thirty preceding days or with a follow-up period of less than six months were excluded. Results. Seventy eight patients were included. The endoscopic findings included mucosal breaks in 50%, ulcerated stenosis in 5%, and villous atrophy in 4%. The diagnosis of CD was established in 31 patients. The sensitivity, specificity, positive and negative predictive value of the endoscopic findings were 93%, 80%, 77%, and 94%, respectively. Capsule retention occurred in four patients (5%). The presence of ulcerated stenosis was significantly more frequent in patients with positive inflammatory markers. The diagnostic yield of capsule enteroscopy in patients with negative ileoscopy was 56%, with a diagnostic acuity of 93%. Small bowel capsule endoscopy is a safe and valid technique for assessing patients with suspected CD. Capsule retention is more frequent in patients with positive inflammatory markers. Patients with negative ileoscopy and suspected CD should be submitted to capsule enteroscopy.
Retention of the capsule endoscope: a single-center experience of 1000 capsule endoscopy procedures.
Li, Feng; Gurudu, Suryakanth R; De Petris, Giovanni; Sharma, Virender K; Shiff, Arthur D; Heigh, Russell I; Fleischer, David E; Post, Janice; Erickson, Paula; Leighton, Jonathan A
2008-07-01
Retention of the video capsule is the most significant complication associated with capsule endoscopy (CE). There are limited data on incidence, risk factors, and outcomes of capsule retention. We aimed to determine the incidence of capsule retention and to investigate the causes and clinical outcomes of capsule retention. Single tertiary referral medical center. All patients who underwent CE for suspected small bowel disease from June 2002 to March 2006. Retrospective case series. Capsule retention occurred in 1.4% of our patients (14/1000). Eleven patients failed to pass the capsule because of nonsteroidal anti-inflammatory drug (NSAID) enteropathy (diaphragm disease). One patient had capsule retention from an obstructing carcinoid tumor. Metastatic ovarian cancer with invasion of the ileum was the cause of retention in another patient. One patient who did not have surgical removal of the capsule because of loss of follow-up had retention caused by a small-bowel tumor suspicious for carcinoid tumor on CT enterography. All patients remained "asymptomatic" from the retained capsules. Thirteen patients underwent elective partial small-bowel resection and capsule removal. No deaths were associated with these surgeries. Eleven patients recovered promptly, whereas 2 patients had mild postoperative ileus. Retrospective study. Retention of the capsule endoscope appears to be infrequent. The most common cause is diaphragm disease resulting from NSAIDs in this study population. In most cases, capsule retention is asymptomatic, and it usually leads to surgical removal, which appears safe and also identifies and treats the underlying small-bowel condition.
Barbosa, Daniel J C; Ramos, Jaime; Lima, Carlos S
2008-01-01
Capsule endoscopy is an important tool to diagnose tumor lesions in the small bowel. The capsule endoscopic images possess vital information expressed by color and texture. This paper presents an approach based in the textural analysis of the different color channels, using the wavelet transform to select the bands with the most significant texture information. A new image is then synthesized from the selected wavelet bands, trough the inverse wavelet transform. The features of each image are based on second-order textural information, and they are used in a classification scheme using a multilayer perceptron neural network. The proposed methodology has been applied in real data taken from capsule endoscopic exams and reached 98.7% sensibility and 96.6% specificity. These results support the feasibility of the proposed algorithm.
Application of wireless power transmission systems in wireless capsule endoscopy: an overview.
Basar, Md Rubel; Ahmad, Mohd Yazed; Cho, Jongman; Ibrahim, Fatimah
2014-06-19
Wireless capsule endoscopy (WCE) is a promising technology for direct diagnosis of the entire small bowel to detect lethal diseases, including cancer and obscure gastrointestinal bleeding (OGIB). To improve the quality of diagnosis, some vital specifications of WCE such as image resolution, frame rate and working time need to be improved. Additionally, future multi-functioning robotic capsule endoscopy (RCE) units may utilize advanced features such as active system control over capsule motion, drug delivery systems, semi-surgical tools and biopsy. However, the inclusion of the above advanced features demands additional power that make conventional power source methods impractical. In this regards, wireless power transmission (WPT) system has received attention among researchers to overcome this problem. Systematic reviews on techniques of using WPT for WCE are limited, especially when involving the recent technological advancements. This paper aims to fill that gap by providing a systematic review with emphasis on the aspects related to the amount of transmitted power, the power transmission efficiency, the system stability and patient safety. It is noted that, thus far the development of WPT system for this WCE application is still in initial stage and there is room for improvements, especially involving system efficiency, stability, and the patient safety aspects.
Saurin, Jean-Christophe; Jacob, Philippe; Heyries, Laurent; Pesanti, Christian; Cholet, Franck; Fassler, Isaac; Boulant, James; Bramli, Slim; De Leusse, Antoin; Rahmi, Gabriel
2018-05-01
Reducing the reading time of capsule endoscopy films is of high priority for gastroenterologists. We report a prospective multicenter evaluation of an "express view" reading mode (Intromedic capsule system). Eighty-three patients with obscure gastrointestinal bleeding were prospectively included in 10 centers. All patients underwent small-bowel capsule endoscopy (Intromedic, Seoul, Republic of Korea). Films were read in standard mode, then a second reading was performed in express view mode at a second center. For each lesion, the precise location, nature, and relevance were collected. A consensus reading and review were done by three experts, and considered to be the gold standard. The mean reading time of capsule films was 39.7 minutes (11 - 180 minutes) and 19.7 minutes (4 - 40 minutes) by standard and express view mode, respectively ( P < 1 × 10 - 4 ). The consensus review identified a significant lesion in 44/83 patients (53.0 %). Standard reading and express view reading had a 93.3 % and 82.2 % sensitivity, respectively (NS). Consensus review identified 70 significant images from which standard reading and express view reading detected 58 (82.9 %) and 55 (78.6 %), respectively. The informatics algorithm detected 66/70 images (94.3 %) thus missing four small-bowel angiodysplasia. The express view algorithm allows an important shortening of Intromedic capsule film reading time with a high sensitivity.
Usefulness of positron emission tomography in primary intestinal follicular lymphoma
Tari, Akira; Asaoku, Hideki; Kunihiro, Masaki; Tanaka, Shinji; Yoshino, Tadashi
2013-01-01
Double-balloon enteroscopy (DBE) and video capsule endoscopy are useful for the diagnosis of lymphoma in the small intestine. However, DBE cannot be safely performed in cases with passage disturbance due to wall thickening and stenosis. Additionally, video capsule endoscopy cannot be performed in such cases because of the risk of retention. Here, we report 4 cases of primary follicular lymphoma of the gastrointestinal tract that could be detected using 18F-fluorodeoxyglucose positron emission tomography combined with computed tomography (PET-CT). The endoscopic findings of these 4 cases included lesions with wall thickening, which comprised macroscopically clusters of nodules, dense clusters of whitish granules or small nodules, fold thickening and ulcers with irregular margins that occupied the whole lumen with edematous mucosa. All patients fulfilled the World Health Organization grade 1 criteria. 18F-fluorodeoxyglucose PET-CT can help predict the risks that may result from certain endoscopic examinations, such as DBE and video capsule endoscopy. PMID:23569346
Endoscopy in inflammatory bowel disease when and why
Rameshshanker, Rajaratnam; Arebi, Naila
2012-01-01
Endoscopy plays an important role in the diagnosis and management of inflammatory bowel disease (IBD). It is useful to exclude other aetiologies, differentiate between ulcerative colitis (UC) and Crohn’s disease (CD), and define the extent and activity of inflammation. Ileocolonoscopy is used for monitoring of the disease, which in turn helps to optimize the management. It plays a key role in the surveillance of UC for dysplasia or neoplasia and assessment of post operative CD. Capsule endoscopy and double balloon enteroscopy are increasingly used in patients with CD. Therapeutic applications relate to stricture dilatation and dysplasia resection. The endoscopist’s role is vital in the overall management of IBD. PMID:22720120
Aspiration of capsule endoscope and successful bronchoscopic extraction.
Girdhar, Ankur; Usman, Faisal; Bajwa, Abubakr
2012-10-01
Capsule endoscopy is a novel tool for the diagnosis of small intestinal disorders. Recently, a new complication of the procedure in the form of the capsule's aspiration into the lungs has been reported. The aspiration of capsule endoscope can lead to a variety of complications including respiratory failure. A low threshold to suspect this complication and urgent bronchoscopic extraction in appropriate patients can prevent serious sequelae.
Ara, Perzila; Cheng, Shaokoon; Heimlich, Michael; Dutkiewicz, Eryk
2015-01-01
Recent developments in capsule endoscopy have highlighted the need for accurate techniques to estimate the location of a capsule endoscope. A highly accurate location estimation of a capsule endoscope in the gastrointestinal (GI) tract in the range of several millimeters is a challenging task. This is mainly because the radio-frequency signals encounter high loss and a highly dynamic channel propagation environment. Therefore, an accurate path-loss model is required for the development of accurate localization algorithms. This paper presents an in-body path-loss model for the human abdomen region at 2.4 GHz frequency. To develop the path-loss model, electromagnetic simulations using the Finite-Difference Time-Domain (FDTD) method were carried out on two different anatomical human models. A mathematical expression for the path-loss model was proposed based on analysis of the measured loss at different capsule locations inside the small intestine. The proposed path-loss model is a good approximation to model in-body RF propagation, since the real measurements are quite infeasible for the capsule endoscopy subject.
NASPGHAN Capsule Endoscopy Clinical Report.
Friedlander, Joel A; Liu, Quin Y; Sahn, Benjamin; Kooros, Koorosh; Walsh, Catharine M; Kramer, Robert E; Lightdale, Jenifer R; Khlevner, Julie; McOmber, Mark; Kurowski, Jacob; Giefer, Matthew J; Pall, Harpreet; Troendle, David M; Utterson, Elizabeth C; Brill, Herbert; Zacur, George M; Lirio, Richard A; Lerner, Diana G; Reynolds, Carrie; Gibbons, Troy E; Wilsey, Michael; Liacouras, Chris A; Fishman, Douglas S
2017-03-01
Wireless capsule endoscopy (CE) was introduced in 2000 as a less invasive method to visualize the distal small bowel in adults. Because this technology has advanced it has been adapted for use in pediatric gastroenterology. Several studies have described its clinical use, utility, and various training methods but pediatric literature regarding CE is limited. This clinical report developed by the Endoscopic and Procedures Committee of the North American Society of Pediatric Gastroenterology, Hepatology and Nutrition outlines the current literature, and describes the recommended current role, use, training, and future areas of research for CE in pediatrics.
Automatic blood detection in capsule endoscopy video
NASA Astrophysics Data System (ADS)
Novozámský, Adam; Flusser, Jan; Tachecí, Ilja; Sulík, Lukáš; Bureš, Jan; Krejcar, Ondřej
2016-12-01
We propose two automatic methods for detecting bleeding in wireless capsule endoscopy videos of the small intestine. The first one uses solely the color information, whereas the second one incorporates the assumptions about the blood spot shape and size. The original idea is namely the definition of a new color space that provides good separability of blood pixels and intestinal wall. Both methods can be applied either individually or their results can be fused together for the final decision. We evaluate their individual performance and various fusion rules on real data, manually annotated by an endoscopist.
Ohta, Hidetoshi; Katsuki, Shinichi
2014-01-01
Ever since capsule endoscopy (CE) was introduced into clinical practice, we gastroenterologists have been dreaming of using this less invasive modality to explore the entire gastrointestinal (GI) tract. To realize this dream, we have developed a magnetic navigation system which includes real-time internet streaming of endoscopic video and some useful gadgets (position detection by means of magnetic impedance (MI) sensors and a modified capsule that is "weightless" in water). The design of the weightless capsule made it possible with 0.5T (Tesla) extracorporeal magnets to control the capsule beyond 20cm. A pair of MI sensors on the body surface could detect subtle magnetic flux generated by an intra-capsular magnet in the GI tract by utilizing the space diversity effect which eliminated the interference of terrestrial magnetism. Subjects underwent CE, during which they were free from confinement in the hospital, except for 1 hour when the capsule was manipulated in the stomach and colon. This study had a completion rate of 97.5%. The high completion rate indicates that our system (single capsule endoscopy-SCE) with further improvements could become a viable modality for screening of the entire GI tract.
Impact of the endoscopist's experience on the negative predictive value of capsule endoscopy.
Velayos Jiménez, Benito; Alcaide Suárez, Noelia; González Redondo, Guillermo; Fernández Salazar, Luis; Aller de la Fuente, Rocío; Del Olmo Martínez, Lourdes; Ruiz Rebollo, Lourdes; González Hernández, José Manuel
2017-01-01
The impact of the accumulated experience of the capsule endoscopy (CE) reader on the accuracy of this test is discussed. To determine whether the negative predictive value of CE findings changes along the learning curve. We reviewed the first 900 CE read by 3 gastroenterologists experienced in endoscopy over 8 years. These 900 CE were divided into 3 groups (300 CE each): group 1 consisted of the sum of the first 100 CE read by each of the 3 endoscopists; group 2, the sum of the second 100 and groups 3, the sum of the third 100. Patients with normal CE were monitored for at least 28 months to estimate the negative predictive value. A total of 54 (18%) CE in group 1, 58 (19.3%) in group 2 and 47 (15.6%) in group 3 were normal, although only 34 patients in group 1, 38 in group 2 and 36 in group 3 with normal CE completed follow up and were eventually studied. The negative predictive value was 88.2% in group 1, 89.5% in group 2 and 97% in group 3 (P>.05). The negative predictive value tended to increase, but remained high and did not change significantly after the first 100 when readers are experienced in conventional endoscopy and have preliminary specific training. Copyright © 2016 Elsevier España, S.L.U., AEEH y AEG. All rights reserved.
Liu, Gang; Yan, Guozheng; Zhu, Bingquan; Lu, Li
2016-11-01
In recent years, wireless capsule endoscopy (WCE) has been a state-of-the-art tool to examine disorders of the human gastrointestinal tract painlessly. However, system miniaturization, enhancement of the image-data transfer rate and power consumption reduction for the capsule are still key challenges. In this paper, a video capsule endoscopy system with a low-power controlling and processing application-specific integrated circuit (ASIC) is designed and fabricated. In the design, these challenges are resolved by employing a microimage sensor, a novel radio frequency transmitter with an on-off keying modulation rate of 20 Mbps, and an ASIC structure that includes a clock management module, a power-efficient image compression module and a power management unit. An ASIC-based prototype capsule, which measures Φ11 mm × 25 mm, has been developed here. Test results show that the designed ASIC consumes much less power than most of the other WCE systems and that its total power consumption per frame is the least. The image compression module can realize high near-lossless compression rate (3.69) and high image quality (46.2 dB). The proposed system supports multi-spectral imaging, including white light imaging and autofluorescence imaging, at a maximum frame rate of 24 fps and with a resolution of 400 × 400. Tests and in vivo trials in pigs have proved the feasibility of the entire system, but further improvements in capsule control and compression performance inside the ASIC are needed in the future.
Shiotani, Akiko; Honda, Keisuke; Kawakami, Makiko; Kimura, Yoshiki; Yamanaka, Yoshiyuki; Fujita, Minoru; Matsumoto, Hiroshi; Tarumi, Ken-ichi; Manabe, Noriaki; Haruma, Ken
2012-01-01
The aim was to investigate the clinical utility of RAPID Access 6.5 Quickview software and to evaluate whether preview of the capsule endoscopy video by a trained nurse could detect significant lesions accurately compared with endoscopists. As reading capsule endoscopy is time consuming, one possible cost-effective strategy could be the use of trained nonphysicians or newly available software to preread and identify potentially important capsule images. The 100 capsule images of a variety of significant lesions from 87 patients were investigated. The minimum percentages for settings of sensitivity that could pick up the selected images and the detection rate for significant lesions by a well-trained nurse, two endoscopists with limited experience in reading, and one well-trained physician were examined. The frequency of the selected lesions picked up by Quickview mode using percentages for sensitivity settings of 5%, 15%, 25%, and 35% were 61%, 74%, 93%, and 98%, respectively. The percentages for sensitivity significantly correlated (r=0.78, P<0.001) with the reading time. The detection rate by the nurse or the well-trained physician was significantly higher than that by the physician with limited capsule experience (87% and 84.1% vs. 62.7%; P<0.01). The clinical use of Quickview at 25% did not significantly improve the detection rate. Quickview mode can reduce reading time but has an unacceptably miss rate for potentially important lesions. Use of a trained nonphysician assistant can reduce physician's time and improve diagnostic yield.
Rey, Jean-Francois; Ogata, Haruhiko; Hosoe, Naoki; Ohtsuka, Kazuo; Ogata, Noriyuki; Ikeda, Keiichi; Aihara, Hiroyuki; Pangtay, Ileana; Hibi, Toshifumi; Kudo, Shin-ei; Tajiri, Hisao
2012-02-01
Passive video capsule endoscopy is the criterion standard for small-bowel exploration but cannot be used for the large gastric cavity. We report the first blinded comparative clinical trial in humans comparing a magnetically guided capsule endoscope (MGCE) and a conventional high-definition gastroscope. To assess the potential of gastric examination with a guided capsule. Blinded, nonrandomized comparative study. Single endoscopy center. The trial involved 61 patients included in a blinded capsule and gastroscopy comparative study. MGCE examination was performed 24 hours after patients had undergone gastroscopy. To remove food residue or mucus, patients drank 900 mL of water in 2 portions. Then to provide the air-water interface required by the guidance system, they drank 400 mL of water at 35°C. Visualization of the gastric pylorus, antrum, body, fundus, and cardia was evaluated as complete in 88.5%, 86.9%, 93.4%, 85.2%, and 88.5% of patients, respectively. Of gastric lesions, 58.3% were detected by both gastroscopy and MGCE at immediate assessment and review of recorded data. Capsule examination missed 14 findings and gastroscopy missed 31 findings seen with MGCE. Overall diagnostic yield was similar for both modalities. Pilot study. Diagnostic results were similar for the 2 methods. After some technical difficulties related to gastric expansion or presence of mucus had been overcome, this study opened a new field for noninvasive gastric examination in countries where high gastric cancer incidence demands a screening tool. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Figueiredo, Pedro; Almeida, Nuno; Lopes, Sandra; Duque, Gabriela; Freire, Paulo; Lérias, Clotilde; Gouveia, Hermano; Sofia, Carlos
2010-01-01
Background. The aim of this work was to assess the value of capsule enteroscopy in the diagnosis of patients with suspected Crohn's Disease (CD). Methods. This was a retrospective study in a single tertiary care centre involving patients undergoing capsule enteroscopy for suspected CD. Patients taking nonsteroidal anti inflammatory drugs during the thirty preceding days or with a follow-up period of less than six months were excluded. Results. Seventy eight patients were included. The endoscopic findings included mucosal breaks in 50%, ulcerated stenosis in 5%, and villous atrophy in 4%. The diagnosis of CD was established in 31 patients. The sensitivity, specificity, positive and negative predictive value of the endoscopic findings were 93%, 80%, 77%, and 94%, respectively. Capsule retention occurred in four patients (5%). The presence of ulcerated stenosis was significantly more frequent in patients with positive inflammatory markers. The diagnostic yield of capsule enteroscopy in patients with negative ileoscopy was 56%, with a diagnostic acuity of 93%. Conclusions. Small bowel capsule endoscopy is a safe and valid technique for assessing patients with suspected CD. Capsule retention is more frequent in patients with positive inflammatory markers. Patients with negative ileoscopy and suspected CD should be submitted to capsule enteroscopy. PMID:20811612
Small-bowel capsule endoscopy: A ten-point contemporary review
Koulaouzidis, Anastasios; Rondonotti, Emanuele; Karargyris, Alexandros
2013-01-01
The introduction of capsule endoscopy (CE) in clinical practice increased the interest for the study of the small-bowel. Consequently, in about 10 years, an impressive quantity of literature on indications, diagnostic yield (DY), safety profile and technical evolution of CE has been published as well as several reviews. At present time, there are 5 small-bowel capsule enteroscopy (SBCE) models in the worldwide market. Head-to-head trials have showed in the great majority of studies comparable results in terms of DY, image quality and completion rate. CE meta-analyses formed the basis of national/international guidelines; these guidelines place CE in a prime position for the diagnostic work-up of patients with obscure gastrointestinal bleeding, known and/or suspected Crohn’s disease and possible small-bowel neoplasia. A 2-L polyethylene glycol-based purge, administered the day before the procedure, is the most widely practiced preparation regimen. Whether this regimen can be further improved (i.e., by further decreasing its volume, changing the timing of administration, coupling it with prokinetics and/or other factors) or if it can really affect the DY, is still under discussion. Faecal calprotectin has been used in SBCE studies in two settings: in patients taking non-steroidal anti-inflammatory drugs, to evaluate the type and extent of mucosal damage and, more importantly from a clinical point of view, in patients with known or suspected Crohn’s disease for assessment of inflammation activity. Although there is still a lot of debate around the exact reasons of SBCE poor performance in various small-bowel segments, it is worth to remember that the capsule progress is non-steerable, hence more rapid in the proximal than in lower segments of the small-bowel. Capsule aspiration, a relatively unexpected complication, has been reported with increasing frequency. This is probably related with the increase in the mean age of patients undergoing CE. CE video review is a time-consuming procedure. Therefore, several attempts have been made to develop technical software features, in order to make CE video analysis easier and shorter (without jeopardizing its accuracy). Suspected Blood Indicator, QuickView and Fujinon Intelligent Chromo Endoscopy are some of the software tools that have been checked in various clinical studies to date. PMID:23840112
Head or tail: the orientation of the small bowel capsule endoscope movement in the small bowel.
Kopylov, Uri; Papageorgiou, Neofytos P; Nadler, Moshe; Eliakim, Rami; Ben-Horin, Shomron
2012-03-01
The diagnostic accuracy of capsule endoscopy has been suggested to be influenced by the direction of the passage in the intestine. It is currently unknown if a head-first or a tail-first orientation are equally common during the descent through the small bowel. The aim of the study was to identify the orientation of the capsule along the migration through the small bowel. Thirty capsule endoscopies were reviewed by an experienced observer. The direction of the passage through the pylorus and the ileoceccal valve was recorded for all the examinations. In addition, detailed review of the passage of the capsule in different segments of the small bowel was undertaken for all the capsules. The capsule was significantly more likely to pass the pylorus head-first compared to tail-first (25 and 5 out of 30, respectively, OR 5, 95% CI 65-94%, P < 0.001). In 28/30 studies, the capsule exited the ileoceccal valve head-first (OR-14, 95% CI 77-99%, P < 0.001). In an immersion experiment, uneven distribution of weight of the capsule body was demonstrated with the head part (camera tip) being lighter than the tail part. The capsule endoscope usually passes through the pylorus and subsequent segments of the small bowel head-first. This observation suggests that the intestinal peristaltic physiology drives symmetrical bodies with their light part first. The principle of intestinal orientation by weight distribution may bear implications for capsules' design in the future.
Strosberg, Jonathan R; Shibata, David; Kvols, Larry K
2007-01-01
A 43-year-old man with a history of metastatic carcinoid disease is presented. The patient had symptoms of chronic intermittent abdominal pain two years after undergoing a wireless capsule endoscopy procedure. Radiological examinations revealed a retained capsule endoscope, and the patient underwent exploratory laparotomy with capsule retrieval. To the authors’ knowledge, this is the first case presentation of chronic, partial small bowel obstruction caused by unrecognized retention of a capsule endoscope. PMID:17299616
Small bowel capsule endoscopy: Where are we after almost 15 years of use?
Van de Bruaene, Cedric; De Looze, Danny; Hindryckx, Pieter
2015-01-01
The development of capsule endoscopy (CE) in 2001 has given gastroenterologists the opportunity to investigate the small bowel in a non-invasive way. CE is most commonly performed for obscure gastrointestinal bleeding, but other indications include diagnosis or follow-up of Crohn’s disease, suspicion of a small bowel tumor, diagnosis and surveillance of hereditary polyposis syndromes, Nonsteroidal anti-inflammatory drug-induced small bowel lesions and celiac disease. Almost fifteen years have passed since the release of the small bowel capsule. The purpose of this review is to offer the reader a brief but complete overview on small bowel CE anno 2014, including the technical and procedural aspects, the possible complications and the most important indications. We will end with some future perspectives of CE. PMID:25610531
Development of an Implantable WBAN Path-Loss Model for Capsule Endoscopy
NASA Astrophysics Data System (ADS)
Aoyagi, Takahiro; Takizawa, Kenichi; Kobayashi, Takehiko; Takada, Jun-Ichi; Hamaguchi, Kiyoshi; Kohno, Ryuji
An implantable WBAN path-loss model for a capsule endoscopy which is used for examining digestive organs, is developed by conducting simulations and experiments. First, we performed FDTD simulations on implant WBAN propagation by using a numerical human model. Second, we performed FDTD simulations on a vessel that represents the human body. Third, we performed experiments using a vessel of the same dimensions as that used in the simulations. On the basis of the results of these simulations and experiments, we proposed the gradient and intercept parameters of the simple path-loss in-body propagation model.
Short article: Aspiration of capsule endoscopes: a comprehensive review of the existing literature.
Yung, Diana E; Plevris, John N; Koulaouzidis, Anastasios
2017-04-01
Capsule endoscopy (CE) has an excellent safety profile. Although retention is the most cited complication, capsule aspiration is less frequent and is often reported only as isolated cases. This study represents a systematic effort to compile and scrutinize the available data on capsule aspiration to provide comprehensive and conclusive information on this CE complication. A systematic literature search was performed in PubMed, Embase and Chinese National Knowledge Infrastructure. The search terms used were 'capsule endoscopy' AND 'aspiration' (both terms searched as keyword and MeSH). We included case reports and/or series on capsule aspiration, as well as observational cohort studies that reported capsule aspiration among their complications/outcomes. Thirty-four case reports with 37 cases of capsule aspiration were identified. A further four observational studies reported aspiration as part of a cohort of patients undergoing CE. 94.6% of aspirations occurred in elderly men. 87.1% had significant comorbidities. 59.5% had symptoms on aspiration, with cough reported most frequently. The most common location of aspiration was the right main bronchus. Half of the patients required intervention for capsule retrieval; bronchoscopy was the most common management, with good effect. There was a single fatality following capsule aspiration, not directly related to the procedure, and one case of aspiration pneumonia. Outcomes were good for all other patients. The estimated overall aspiration rate is 0.1%. Although very rare and generally safely managed, capsule aspiration should be anticipated in certain patient groups and capsule administration should be approached with necessary precautions.
Gralnek, I M; Adler, S N; Yassin, K; Koslowsky, B; Metzger, Y; Eliakim, R
2008-04-01
Esophageal capsule endoscopy (ECE) provides an alternative, minimally invasive modality for evaluating the esophagus. This study evaluates the performance and test characteristics of a second-generation esophageal capsule endoscope, the PillCam ESO 2. Adults with known or suspected esophageal disease were included. Using the simplified ingestion procedure, each patient underwent capsule endoscopy with the PillCam ESO 2. Following ECE, esophagogastroduodenoscopy (EGD) was performed on the same day by an investigator who was blinded to the results of the ECE. In random order, capsule endoscopy videos were read and interpreted by the study investigator blinded to EGD results. 28 patients (19 men, 9 women; mean age 53.3 years) were included. In 82 % of the patients, at least 75 % of the Z line was visualized by the PillCam ESO 2. A per-lesion analysis demonstrated that the PillCam ESO 2 had definitive results in 30/43 lesions (69.8 %) and EGD in 29/43 (67.4 %), P value = 0.41. Compared with EGD for detecting suspected Barrett's esophagus and esophagitis, the PillCam ESO 2 had a sensitivity of 100 % and a specificity of 74 %, and a sensitivity of 80 % and a specificity of 87 %, respectively. The PillCam ESO 2 demonstrated 86 % agreement with EGD in describing the Z line (kappa statistic 0.68). The modified ingestion protocol provided excellent cleansing, with bubbles/saliva having no or only a minor effect on Z line images in 86 % of cases. The PillCam ESO 2 demonstrated excellent visualization of the Z line. Compared with standard EGD, the PillCam ESO 2 had good test characteristics with high rates of detection of suspected Barrett's esophagus and esophagitis. This study provides indirect validation of the simplified ingestion procedure. The PillCam ESO 2 acquires high quality esophageal images, performs safely, and should be able to replace the current PillCam ESO.
An ultra-low-power image compressor for capsule endoscope.
Lin, Meng-Chun; Dung, Lan-Rong; Weng, Ping-Kuo
2006-02-25
Gastrointestinal (GI) endoscopy has been popularly applied for the diagnosis of diseases of the alimentary canal including Crohn's Disease, Celiac disease and other malabsorption disorders, benign and malignant tumors of the small intestine, vascular disorders and medication related small bowel injury. The wireless capsule endoscope has been successfully utilized to diagnose diseases of the small intestine and alleviate the discomfort and pain of patients. However, the resolution of demosaicked image is still low, and some interesting spots may be unintentionally omitted. Especially, the images will be severely distorted when physicians zoom images in for detailed diagnosis. Increasing resolution may cause significant power consumption in RF transmitter; hence, image compression is necessary for saving the power dissipation of RF transmitter. To overcome this drawback, we have been developing a new capsule endoscope, called GICam. We developed an ultra-low-power image compression processor for capsule endoscope or swallowable imaging capsules. In applications of capsule endoscopy, it is imperative to consider battery life/performance trade-offs. Applying state-of-the-art video compression techniques may significantly reduce the image bit rate by their high compression ratio, but they all require intensive computation and consume much battery power. There are many fast compression algorithms for reducing computation load; however, they may result in distortion of the original image, which is not good for use in the medical care. Thus, this paper will first simplify traditional video compression algorithms and propose a scalable compression architecture. As the result, the developed video compressor only costs 31 K gates at 2 frames per second, consumes 14.92 mW, and reduces the video size by 75% at least.
Effect of erythromycin on image quality and transit time of capsule endoscopy: A two-center study
Niv, Eva; Bogner, Ido; Barkay, Olga; Halpern, Zamir; Mahajna, Elisabeth; Depsames, Roman; Kopelman, Yael; Fireman, Zvi
2008-01-01
AIM: To compare the effect of oral erythromycin vs no preparation with prokinetics on the transit time and the image quality of capsule endoscopy (CE) in evaluating small bowel (SB) pathology. METHODS: We conducted a retrospective, blinded (to the type of preparation) review of 100 CE studies, 50 with no preparation with prokinetics from one medical center (Group A) and 50 from another center with administration of a single dose of 200 mg oral erythromycin 1 h prior to CE (Group B). Gastric, SB and total transit times were calculated, the presence of bile in the duodenum was scored, as was cleanliness within the proximal, middle and distal intestine. RESULTS: The erythromycin group had a slightly shorter gastric transit time (21 min vs 28 min, with no statistical significance). SB transit time was similar for both groups (all P > 0.05). Total transit time was almost identical in both groups. The rate of incomplete examination was 16% for Group A and 10% for Group B (P = 0.37). Bile and cleanliness scores in different parts of the intestine were similar for the two groups (P > 0.05). CONCLUSION: Preparation for capsule endoscopy with erythromycin does not affect SB or total transit time. It tends to reduce gastric transit time, but it does not increase the cecum-reaching rate. Erythromycin does not adversely affect image quality. We consider the routine use of oral erythromycin preparation as being unjustified, although it might be considered in patients with known prolonged gastric emptying time. PMID:18442206
Herrerias, Juan M; Leighton, Jonathan A; Costamagna, Guido; Infantolino, Anthony; Eliakim, Rami; Fischer, Doron; Rubin, David T; Manten, Howard D; Scapa, Eitan; Morgan, Douglas R; Bergwerk, Ari J; Koslowsky, Binyamin; Adler, Samuel N
2008-05-01
Capsule endoscopy (CE) of the small bowel has become a standard diagnostic tool, but there have been concerns regarding the risk of capsule retention in certain high-risk groups. The Agile patency system, an ingestible and dissolvable capsule with an external scanner, was developed to allow physicians to perform CE with greater confidence that the capsule will be safely excreted in patients at risk for capsule retention. Our purpose was to assess the ability of the device to help physicians identify which patients with known strictures may safely undergo CE. Patients with known strictures ingested the new patency capsule and underwent periodic scanning until it was excreted. The intestinal tract was considered to be sufficiently patent if the capsule was excreted intact or if the capsule was not detected by the scanner at 30 hours after ingestion. If patency was established, then standard CE was performed. International multicenter study. A total of 106 patients with known strictures. Agile patency system. Performance and safety of Agile patency system. A total of 106 patients ingested the patency capsule. Fifty-nine (56%) excreted it intact and subsequently underwent CE. There were no cases of capsule retention. Significant findings on CE were found in 24 (41%). There were 3 severe adverse events. These results suggest that the Agile patency system is a useful tool for physicians to use before CE in patients with strictures to avoid retention. This group of patients may have a high yield of clinically significant findings at CE. This capsule may determine whether patients who have a contraindication to CE may safely undergo CE and obtain useful diagnostic information.
Endoscopic placement of the small-bowel video capsule by using a capsule endoscope delivery device.
Holden, Jeremy P; Dureja, Parul; Pfau, Patrick R; Schwartz, Darren C; Reichelderfer, Mark; Judd, Robert H; Danko, Istvan; Iyer, Lalitha V; Gopal, Deepak V
2007-05-01
Capsule endoscopy performed via the traditional peroral route is technically challenging in patients with dysphagia, gastroparesis, and/or abnormal upper-GI (UGI) anatomy. To describe the indications and outcomes of cases in which the AdvanCE capsule endoscope delivery device, which has recently been cleared by the Food and Drug Administration, was used. Retrospective, descriptive, case series. Tertiary care, university hospital. We report a case series of 16 consecutive patients in whom the AdvanCE delivery device was used. The study period was May 2005 through July 2006. Endoscopic delivery of the video capsule to the proximal small bowel by using the AdvanCE delivery device. Indications, technique, and completeness of small bowel imaging in patients who underwent endoscopic video capsule delivery. The AdvanCE delivery device was used in 16 patients ranging in age from 3 to 74 years. The primary indications for endoscopic delivery included inability to swallow the capsule (10), altered UGI anatomy (4), and gastroparesis (2). Of the 4 patients with altered UGI anatomy, 3 had dual intestinal loop anatomy (ie, Bilroth-II procedure, Whipple surgery, Roux-en-Y gastric bypass) and 1 had a failed Nissen fundoplication. In all cases, the capsule was easily deployed without complication, and complete small intestinal imaging was achieved. Small patient size. Endoscopic placement of the Given PillCam by use of the AdvanCE delivery device was safe and easily performed in patients for whom capsule endoscopy would otherwise have been contraindicated or technically challenging.
Multilevel wireless capsule endoscopy video segmentation
NASA Astrophysics Data System (ADS)
Hwang, Sae; Celebi, M. Emre
2010-03-01
Wireless Capsule Endoscopy (WCE) is a relatively new technology (FDA approved in 2002) allowing doctors to view most of the small intestine. WCE transmits more than 50,000 video frames per examination and the visual inspection of the resulting video is a highly time-consuming task even for the experienced gastroenterologist. Typically, a medical clinician spends one or two hours to analyze a WCE video. To reduce the assessment time, it is critical to develop a technique to automatically discriminate digestive organs and shots each of which consists of the same or similar shots. In this paper a multi-level WCE video segmentation methodology is presented to reduce the examination time.
Acoustic Sensing and Ultrasonic Drug Delivery in Multimodal Theranostic Capsule Endoscopy
Stewart, Fraser R.; Qiu, Yongqiang; Newton, Ian P.; Cox, Benjamin F.; Al-Rawhani, Mohammed A.; Beeley, James; Liu, Yangminghao; Huang, Zhihong; Cumming, David R. S.; Näthke, Inke
2017-01-01
Video capsule endoscopy (VCE) is now a clinically accepted diagnostic modality in which miniaturized technology, an on-board power supply and wireless telemetry stand as technological foundations for other capsule endoscopy (CE) devices. However, VCE does not provide therapeutic functionality, and research towards therapeutic CE (TCE) has been limited. In this paper, a route towards viable TCE is proposed, based on multiple CE devices including important acoustic sensing and drug delivery components. In this approach, an initial multimodal diagnostic device with high-frequency quantitative microultrasound that complements video imaging allows surface and subsurface visualization and computer-assisted diagnosis. Using focused ultrasound (US) to mark sites of pathology with exogenous fluorescent agents permits follow-up with another device to provide therapy. This is based on an US-mediated targeted drug delivery system with fluorescence imaging guidance. An additional device may then be utilized for treatment verification and monitoring, exploiting the minimally invasive nature of CE. While such a theranostic patient pathway for gastrointestinal treatment is presently incomplete, the description in this paper of previous research and work under way to realize further components for the proposed pathway suggests it is feasible and provides a framework around which to structure further work. PMID:28671642
Pediatric capsule endoscopy: review of the small bowel and patency capsules.
Cohen, Stanley A; Ephrath, Hagit; Lewis, Jeffery D; Klevens, Alan; Bergwerk, Ari; Liu, Steven; Patel, Dinesh; Reed-Knight, Bonney; Stallworth, Angela; Wakhisi, Tamara; Gold, Benjamin D
2012-03-01
Because capsule endoscopy (CE) avoids ionizing radiation, deep sedation, and general anesthesia, CE may be valuable in pediatrics. We report a single pediatric center's experience with the use and safety of CE. In a retrospective review of consecutive CE studies, 284 CE studies were performed in 277 patients with a mean age of 15 (±3.7) years during a 5-year period. The youngest to swallow the capsule was 4.6 years old. Twenty capsules were placed. Overall, 245 (86%) patients underwent CE for suspected (184, 65%) or confirmed (61, 21%) Crohn disease (CD); 27 (9.5%) anemia or gastrointestinal bleeding; 6 (2%) polyposis; and 4 (1.4%) celiac disease. Positive findings were observed in 205 (72%) of the studies, with 152 (54%) having small bowel findings. Of these, 72 (47%) were diagnostic. Gastric (95, 33%) and colonic (31, 11%) abnormalities were also identified. Five CE studies (1.8%) resulted in retention of the capsule in nonsurgical patients. A patency capsule before CE in 23 patients allowed 19 CE to proceed with only 1 retained capsule. In 65 (21%) patients, the video capsule did not enter the colon before the video's end. Of these, 36 (65%) had significant findings, including 27 (49%) documenting small bowel (SB) CD. CE is useful to diagnose SB disease in children. Even in a study population with a high prevalence of confirmed and suspected CD, the risk of retention remains small. The patency capsule may lessen that risk. CE may identify gastric or colonic disease even when SB lesions are not present.
Blood detection in wireless capsule endoscopy using expectation maximization clustering
NASA Astrophysics Data System (ADS)
Hwang, Sae; Oh, JungHwan; Cox, Jay; Tang, Shou Jiang; Tibbals, Harry F.
2006-03-01
Wireless Capsule Endoscopy (WCE) is a relatively new technology (FDA approved in 2002) allowing doctors to view most of the small intestine. Other endoscopies such as colonoscopy, upper gastrointestinal endoscopy, push enteroscopy, and intraoperative enteroscopy could be used to visualize up to the stomach, duodenum, colon, and terminal ileum, but there existed no method to view most of the small intestine without surgery. With the miniaturization of wireless and camera technologies came the ability to view the entire gestational track with little effort. A tiny disposable video capsule is swallowed, transmitting two images per second to a small data receiver worn by the patient on a belt. During an approximately 8-hour course, over 55,000 images are recorded to a worn device and then downloaded to a computer for later examination. Typically, a medical clinician spends more than two hours to analyze a WCE video. Research has been attempted to automatically find abnormal regions (especially bleeding) to reduce the time needed to analyze the videos. The manufacturers also provide the software tool to detect the bleeding called Suspected Blood Indicator (SBI), but its accuracy is not high enough to replace human examination. It was reported that the sensitivity and the specificity of SBI were about 72% and 85%, respectively. To address this problem, we propose a technique to detect the bleeding regions automatically utilizing the Expectation Maximization (EM) clustering algorithm. Our experimental results indicate that the proposed bleeding detection method achieves 92% and 98% of sensitivity and specificity, respectively.
Safety and utility of capsule endoscopy for infants and young children
Oikawa-Kawamoto, Manari; Sogo, Tsuyoshi; Yamaguchi, Takeshi; Tsunoda, Tomoyuki; Kondo, Takeo; Komatsu, Haruki; Inui, Ayano; Fujisawa, Tomoo
2013-01-01
AIM: To assess the safety and utility of capsule endoscopy (CE) for children who are unable to swallow the capsule endoscope. METHODS: The medical records of all of the children who underwent CE between 2010 and 2012 were retrospectively reviewed. The patients were divided into 2 groups: group A included patients who were unable to swallow the capsule endoscope, and group B included patients who were able to swallow it. For the patients who were unable to swallow the capsule endoscope, it was placed in the duodenum endoscopically. The small bowel transit time, endoscopic diagnosis and complications of the 2 groups were compared. RESULTS: During the study period, 28 CE procedures were performed in 26 patients. Group A included 11 patients with a median age of 2 years (range 10 mo-9 years), and group B included 15 patients with a median age of 12 years (range 8 years-16 years). The lightest child in the study weighed 7.9 kg. The detection rates did not differ between the 2 groups. The median small bowel transit time was 401 min (range 264-734 min) in group A and 227 min (range 56-512 min) in group B (P = 0.0078). No serious complications, including capsule retention, occurred. No significant mucosal trauma occurred in the pharynx, esophagus, stomach or duodenum when the capsule was introduced using an endoscope. CONCLUSION: CE is a safe and useful procedure for infants and young children who are unable to swallow the capsule endoscope. PMID:24363526
Spada, C; Spera, G; Riccioni, M; Biancone, L; Petruzziello, L; Tringali, A; Familiari, P; Marchese, M; Onder, G; Mutignani, M; Perri, V; Petruzziello, C; Pallone, F; Costamagna, G
2005-09-01
The current visualization of small-bowel strictures using traditional radiological methods is associated with high radiation doses and false-negative results. These methods do not always reveal small-bowel patency for solids. The aim is to assess the safety of the Given patency system and its ability to detect intestinal strictures in patients with strictures that are known or suspected radiologically. The Given patency capsule is composed of lactose, remains intact in the gastrointestinal tract for 40-100 hours post ingestion, and disintegrates thereafter. A total of 34 patients with small-bowel stricture were prospectively enrolled; 30 had a previous diagnosis of Crohn's disease, three had adhesion syndrome and in one ischemic enteritis was suspected. Of the patients, 15 (44.1 %) had previously undergone surgery. Following ingestion, the capsule was monitored for integrity and transit time, using a specially designed Given scanner and also radiologically. Seventeen patients had been enrolled with the intent of using the patency capsule as a preliminary test in patients with small-bowel strictures before undergoing video capsule endoscopy. 30 patients (88.2 %) retrieved the capsule in the stool; it was intact in 20 (median transit time 22 hours), and disintegrated in 10 patients (median transit time 53 hours). Six patients complained of abdominal pain which disappeared within 24 hours. The scanner successfully indicated the presence of the capsule in 94 % of cases. Ten patients underwent video capsule endoscopy following the patency capsule examination; in all of these the video capsule passed through the small-bowel stricture. This feasibility study has shown that the Given patency capsule is a safe, effective, and convenient tool for assessment of functional patency of the small bowel. It can indicate functional patency even in cases where traditional radiology indicates stricture.
Faerber, Julia; Cummins, Gerard; Pavuluri, Sumanth Kumar; Record, Paul; Rodriguez, Adrian R Ayastuy; Lay, Holly S; McPhillips, Rachael; Cox, Benjamin F; Connor, Ciaran; Gregson, Rachael; Clutton, Richard Eddie; Khan, Sadeque Reza; Cochran, Sandy; Desmulliez, Marc P Y
2018-02-01
This paper describes the design, fabrication, packaging, and performance characterization of a conformal helix antenna created on the outside of a capsule endoscope designed to operate at a carrier frequency of 433 MHz within human tissue. Wireless data transfer was established between the integrated capsule system and an external receiver. The telemetry system was tested within a tissue phantom and in vivo porcine models. Two different types of transmission modes were tested. The first mode, replicating normal operating conditions, used data packets at a steady power level of 0 dBm, while the capsule was being withdrawn at a steady rate from the small intestine. The second mode, replicating the worst-case clinical scenario of capsule retention within the small bowel, sent data with stepwise increasing power levels of -10, 0, 6, and 10 dBm, with the capsule fixed in position. The temperature of the tissue surrounding the external antenna was monitored at all times using thermistors embedded within the capsule shell to observe potential safety issues. The recorded data showed, for both modes of operation, a low error transmission of 10 -3 packet error rate and 10 -5 bit error rate and no temperature increase of the tissue according to IEEE standards.
Albert, J G; Humbla, O; McAlindon, M E; Davison, C; Seitz, U; Fraser, C; Hagenmüller, F; Noetzel, E; Spada, C; Riccioni, M E; Barnert, J; Filmann, N; Keuchel, M
2015-10-01
Small bowel capsule endoscopy (SBCE) has become a first line diagnostic tool. Several training courses with a similar format have been established in Europe; however, data on learning curve and training in SBCE remain sparse.Between 2008 and 2011, different basic SBCE training courses were organized internationally in UK (n = 2), Italy (n = 2), Germany (n = 2), Finland (n = 1), and nationally in Germany (n = 10), applying similar 8-hour curricula with 50% lectures and 50% hands-on training. The Given PillCam System was used in 12 courses, the Olympus EndoCapsule system in 5, respectively. A simple evaluation tool for capsule endoscopy training (ET-CET) was developed using 10 short SBCE videos including relevant lesions and normal or irrelevant findings. For each video, delegates were required to record a diagnosis (achievable total score from 0 to 10) and the clinical relevance (achievable total score 0 to 10). ET-CET was performed at baseline before the course and repeated, with videos in altered order, after the course.Two hundred ninety-four delegates (79.3% physicians, 16.3% nurses, 4.4% others) were included for baseline analysis, 268 completed the final evaluation. Forty percent had no previous experience in SBCE, 33% had performed 10 or less procedures. Median scores for correct diagnosis improved from 4.0 (IQR 3) to 7.0 (IQR 3) during the courses (P < 0.001, Wilcoxon), and for correct classification of relevance of the lesions from 5.0 (IQR 3) to 7.0 (IQR 3) (P < 0.001), respectively. Improvement was not dependent on experience, profession, SBCE system, or course setting. Previous experience in SBCE was associated with higher baseline scores for correct diagnosis (P < 0.001; Kruskal-Wallis). Additionally, independent nonparametric partial correlation with experience in gastroscopy (rho 0.33) and colonoscopy (rho 0.27) was observed (P < 0.001).A simple ET-CET demonstrated significant improvement of diagnostic skills on completion of formal basic SBCE courses with hands-on training, regardless of preexisting experience, profession, and course setting. Baseline scores for correct diagnoses show a plateau after interpretation of 25 SBCE before courses, supporting this number as a compromise for credentialing. Experience in flexible endoscopy may be useful before attending an SBCE course.
Gheorghe, Andrada; Zahiu, Denise Carmen Mihaela; Voiosu, Theodor Alexandru; Mateescu, Bogdan Radu; Voiosu, Mihail Radu; Rimbaş, Mihai
2017-06-01
As already known, spondyloarthritis patients present a striking resemblance in intestinal inflammation with early Crohn's disease. Moreover, the frequent use of nonsteroidal anti-inflammatory drugs is an important part of their treatment. Both conditions could lead to intestinal stenoses. Therefore we proposed to investigate the usefulness of the patency capsule test in patients with spondyloarthritis. 64 consecutive patients (33 males; mean age 38 ± 11 years) that fulfilled the AMOR criteria for seronegative spondyloarthropathy (59.4% ankylosing spondylitis) lacking symptoms or signs of intestinal stenosis were enrolled and submitted to an AGILE™ capsule patency test followed by a video capsule endoscopy (PillCam SB2™), as part of a protocol investigating the presence of intestinal inflammatory lesions. After reviewing the VCE recordings, the Lewis score (of small bowel inflammatory involvement) was computed. In only 5 patients (7.8%) of the study group, the luminal patency test was negative. However, there was no retention of the videocapsule in any of the patients. From the 59 patients with a positive patency test, 3 patients presented single small bowel stenoses (two with ulcerated overlying inflamed mucosa, one cicatricial), all being traversed by the videocapsule along the length of the recording. None of the patients with a negative test had bowel stenoses. There was no correlation between the patency test and the Lewis score, the C reactive protein value, diagnosis of inflammatory bowel disease, or the family history of spondyloarthritis, psoriasis or inflammatory bowel disease. The AGILE patency capsule does not seem to be a useful tool for all patients with spondyloarthritis prior to small bowel videocapsule endoscopy (ClinicalTrial.gov ID NCT 00768950).
Assessment of an electronic learning system for colon capsule endoscopy: a pilot study.
Watabe, Hirotsugu; Nakamura, Tetsuya; Yamada, Atsuo; Kakugawa, Yasuo; Nouda, Sadaharu; Terano, Akira
2016-06-01
Training for colon capsule endoscopy (CCE) procedures is currently performed as a lecture and hands-on seminar. The aims of this pilot study were to assess the utility of an electronic learning system for CCE (ELCCE) designed for the Japanese Association for Capsule Endoscopy using an objective scoring engine, and to evaluate the efficacy of ELCCE on the acquisition of CCE reading competence. ELCCE is an Internet-based learning system with the following steps: step 1, introduction; step 2, CCE reading competence assessment test (CCAT), which evaluates the competence of CCE reading prior to training; step 3, learning reading theory; step 4, training with guidance; step 5, training without guidance; step 6, final assessment; and step 7, the same as step 2. The CCAT, step 5 and step 6 were scored automatically according to: lesion detection, diagnosis (location, size, shape of lesion), management recommendations, and quality of view. Ten trainee endoscopists were initially recruited (cohort 1), followed by a validating cohort of 11 trainee endoscopists (cohort 2). All but one participant finished ELCCE training within 7 weeks. In step 6, accuracy ranged from 53 to 98 % and was not impacted by step 2 pretest scores. The average CCAT scores significantly increased between step 2 pretest and step 7 in both cohorts, from 42 ± 18 % to 79 ± 15 % in cohort 1 (p = 0.0004), and from 52 ± 15 % to 79 ± 14 % in cohort 2 (p = 0.0003). ELCCE is useful and effective for improving CCE reading competence.
Modular "plug-and-play" capsules for multi-capsule environment in the gastrointestinal tract.
Phee, S J; Ting, E K; Lin, L; Huynh, V A; Kencana, A P; Wong, K J; Tan, S L
2009-01-01
The invention of wireless capsule endoscopy has opened new ways of diagnosing and treating diseases in the gastrointestinal tract. Current wireless capsules can perform simple operations such as imaging and data collection (like temperature, pressure, and pH) in the gastrointestinal tract. Researchers are now focusing on adding more sophisticated functions such as drug delivery, surgical clips/tags deployment, and tissue samples collection. The finite on-board power on these capsules is one of the factors that limits the functionalities of these wireless capsules. Thus multiple application-specific capsules would be needed to complete an endoscopic operation. This would give rise to a multi-capsule environment. Having a modular "plug-and-play" capsule design would facilitate doctors in configuring multiple application-specific capsules, e.g. tagging capsule, for use in the gastrointestinal tract. This multi-capsule environment also has the advantage of reducing power consumption through asymmetric multi-hop communication.
A modular and programmable development platform for capsule endoscopy system.
Khan, Tareq Hasan; Shrestha, Ravi; Wahid, Khan A
2014-06-01
The state-of-the-art capsule endoscopy (CE) technology offers painless examination for the patients and the ability to examine the interior of the gastrointestinal tract by a noninvasive procedure for the gastroenterologists. In this work, a modular and flexible CE development system platform consisting of a miniature field programmable gate array (FPGA) based electronic capsule, a microcontroller based portable data recorder unit and computer software is designed and developed. Due to the flexible and reprogrammable nature of the system, various image processing and compression algorithms can be tested in the design without requiring any hardware change. The designed capsule prototype supports various imaging modes including white light imaging (WLI) and narrow band imaging (NBI), and communicates with the data recorder in full duplex fashion, which enables configuring the image size and imaging mode in real time during examination. A low complexity image compressor based on a novel color-space is implemented inside the capsule to reduce the amount of RF transmission data. The data recorder contains graphical LCD for real time image viewing and SD cards for storing image data. Data can be uploaded to a computer or Smartphone by SD card, USB interface or by wireless Bluetooth link. Computer software is developed that decompresses and reconstructs images. The fabricated capsule PCBs have a diameter of 16 mm. An ex-vivo animal testing has also been conducted to validate the results.
Safety and utility of capsule endoscopy for infants and young children.
Oikawa-Kawamoto, Manari; Sogo, Tsuyoshi; Yamaguchi, Takeshi; Tsunoda, Tomoyuki; Kondo, Takeo; Komatsu, Haruki; Inui, Ayano; Fujisawa, Tomoo
2013-12-07
To assess the safety and utility of capsule endoscopy (CE) for children who are unable to swallow the capsule endoscope. The medical records of all of the children who underwent CE between 2010 and 2012 were retrospectively reviewed. The patients were divided into 2 groups: group A included patients who were unable to swallow the capsule endoscope, and group B included patients who were able to swallow it. For the patients who were unable to swallow the capsule endoscope, it was placed in the duodenum endoscopically. The small bowel transit time, endoscopic diagnosis and complications of the 2 groups were compared. During the study period, 28 CE procedures were performed in 26 patients. Group A included 11 patients with a median age of 2 years (range 10 mo-9 years), and group B included 15 patients with a median age of 12 years (range 8 years-16 years). The lightest child in the study weighed 7.9 kg. The detection rates did not differ between the 2 groups. The median small bowel transit time was 401 min (range 264-734 min) in group A and 227 min (range 56-512 min) in group B (P = 0.0078). No serious complications, including capsule retention, occurred. No significant mucosal trauma occurred in the pharynx, esophagus, stomach or duodenum when the capsule was introduced using an endoscope. CE is a safe and useful procedure for infants and young children who are unable to swallow the capsule endoscope. © 2013 Baishideng Publishing Group Co., Limited. All rights reserved.
Niv, Yaron
2017-07-01
Capsule endoscopy (CE) may be used for the evaluation and follow-up of patients with Crohn's disease. CE scores correspond to the degree of mucosal inflammation, a major therapeutic target. The aim of this meta-analysis and systematic review was to determine whether mucosal healing assessment by CE may serve as a predictor of clinical remission in patients with Crohn's disease. To identify observational or controlled English-language full-text studies assessing mucosal healing by CE in patients with Crohn's disease up to 30 September 2016, we searched PubMed, Embase, Central, Medline, and Scopus using the key words 'mucosal healing' and 'capsule endoscopy'. A meta-analysis was carried out using 'Comprehensive meta-analysis' software. Pooled odds ratios and 95% confidence intervals were calculated. Five observational studies including 142 patients from five countries fulfilled the inclusion criteria. No publication bias was found by funnel plot. The mucosal healing CE score was found to be significantly associated with improved outcome after a follow-up of 12 weeks to 24 months, with an odds ratio of 11.06 (95% confidence interval: 3.74-32.73, P<0.001). The degree of heterogeneity among the studies was small (Q=2.014, d.f.[Q]=3, P=0.569 and I=0). Endoscopy scores may play a role in the long-term prognostic evaluation of patients with Crohn's disease. Our results may be accepted as proof of concept, but larger studies are needed to corroborate these findings.
Kobaek-Larsen, M; Kroijer, R; Dyrvig, A-K; Buijs, M M; Steele, R J C; Qvist, N; Baatrup, G
2018-06-01
The aim was to determine the polyp detection rate and per-patient sensitivity for polyps > 9 mm of colon capsule endoscopy (CCE) compared with colonoscopy as well as the diagnostic accuracy of CCE. Individuals who had a positive immunochemical faecal occult blood test during screening had investigator blinded CCE and colonoscopy. Participants underwent repeat endoscopy if significant lesions detected by CCE were considered to have been missed by colonoscopy. There were 253 participants. The polyp detection rate was significantly higher in CCE compared with colonoscopy (P = 0.02). The per-patient sensitivity for > 9 mm polyps for CCE and colonoscopy was 87% (95% CI: 83-91%) and 88% (95% CI: 84-92%) respectively. In participants with complete CCE and colonoscopy examinations (N = 126), per-patient sensitivity of > 9 mm polyps in CCE (97%; 95% CI: 94-100%) was superior to colonoscopy (89%; 95% CI: 84-94%). A complete capsule endoscopy examination (N = 134) could detect patients with intermediate or greater risk (according to the European guidelines) with an accuracy, sensitivity, specificity and positivity rate of 79%, 93%, 69% and 58% respectively, using a cut-off of at least one polyp > 10 mm or more than two polyps. CCE is superior to colonoscopy in polyp detection rate and per-patient sensitivity to > 9 mm polyps, but only in complete CCE examinations. The rate of incomplete CCE examinations must be improved. Colorectal Disease © 2017 The Association of Coloproctology of Great Britain and Ireland.
Capsule endoscopy in pediatrics: a 10-years journey.
Oliva, Salvatore; Cohen, Stanley A; Di Nardo, Giovanni; Gualdi, Gianfranco; Cucchiara, Salvatore; Casciani, Emanuele
2014-11-28
Video capsule endoscopy (CE) for evaluation the esophagus (ECE), small bowel (SBCE) and the colon (CCE) is particularly useful in pediatrics, because this imaging modality does not require ionizing radiation, deep sedation or general anesthesia. The risk of capsule retention appears to be dependent on indication rather than age and parallels the adult experience by indication, making SBCE a relatively safe procedure with a significant diagnostic yield. The newest indication, assessment of mucosal change, greatly enhances and expands its potential benefit. The diagnostic role of CE extends beyond the SB. The use of ECE also may enhance our knowledge of esophageal disease and assist patient care. Colon CCE is a novel minimally invasive and painless endoscopic technique allowing exploration of the colon without need for sedation, rectal intubation and gas insufflation. The limited data on ECE and CCE in pediatrics does not yet allow the same conclusions regarding efficacy; however, both appear to provide safe methods to assess and monitor mucosal change in their respective areas with little discomfort. Moreover, although experience has been limited, the patency capsule may help lessen the potential of capsule retention; and newly researched protocols for bowel cleaning may further enhance CE's diagnostic yield. However, further research is needed to optimize the use of the various CE procedures in pediatric populations.
Ultrahigh speed en face OCT capsule for endoscopic imaging
Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G.
2015-01-01
Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications. PMID:25909001
Ultrahigh speed en face OCT capsule for endoscopic imaging.
Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G
2015-04-01
Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications.
Sun, Tianjia; Xie, Xiang; Li, Guolin; Gu, Yingke; Deng, Yangdong; Wang, Zhihua
2012-11-01
This paper presents a wireless power transfer system for a motion-free capsule endoscopy inspection. Conventionally, a wireless power transmitter in a specifically designed jacket has to be connected to a strong power source with a long cable. To avoid the power cable and allow patients to walk freely in a room, this paper proposes a two-hop wireless power transfer system. First, power is transferred from a floor to a power relay in the patient's jacket via strong coupling. Next, power is delivered from the power relay to the capsule via loose coupling. Besides making patients much more conformable, the proposed techniques eliminate the sources of reliability issues arisen from the moving cable and connectors. In the capsule, it is critical to enhance the power conversion efficiency. This paper develops a switch-mode rectifier (rectifying efficiency of 93.6%) and a power combination circuit (enhances combining efficiency by 18%). Thanks to the two-hop transfer mechanism and the novel circuit techniques, this system is able to transfer an average power of 24 mW and a peak power of 90 mW from the floor to a 13 mm × 27 mm capsule over a distance of 1 m with the maximum dc-to-dc power efficiency of 3.04%.
NASA Astrophysics Data System (ADS)
Hilbich, D.; Rahbar, A.; Khosla, A.; Gray, B. L.
2012-10-01
We present the initial experimental results for manipulating micro-robots featuring permanent magnetic polymer magnets for guided wireless endoscopy applications. The magnetic polymers are fabricated by doping polydimethylsiloxane (PDMS) with permanent isotropic rare earth magnetic powder (MQFP 12-5) with an average particle size of 6 μm. The prepared magnetic nanocomposite polymer (M-NCP) is patterned in the desired shape against a plexiglass mold via soft lithography techniques. It is observed that the fabricated micro-robot magnets have a magnetic field strength of 50 mT and can easily be actuated by applying a field of 8.3 mT (field measured at the capsule's position) and moved at a rate of 5 inches/second.
Swallowable capsule with air channel for improved image-guided cancer detection in the esophagus
NASA Astrophysics Data System (ADS)
Seibel, Eric J.; Melville, C. David; Lung, Jonathan K. C.; Babchanik, Alexander P.; Lee, Cameron M.; Johnston, Richard S.; Dominitz, Jason A.
2009-02-01
A new type of endoscope has been developed and tested in the human esophagus, a tethered-capsule endoscope (TCE) that requires no sedation for oral ingestion and esophageal inspection. The TCE uses scanned red, green, and blue laser light to image the upper digestive tract using a swallowable capsule of 6.4mm in diameter and 18mm in length on a 1.4mm diameter tether. The TCE has been modified for image-guided interventions in the lower esophagus, specifically for more effective detection and measurement of the extent of Barrett's esophagus, a precursor to esophageal cancer. Three modifications have been tested in vivo: (1) weighting the capsule so it is negatively buoyant in water, (2) increasing the frame rate of 500-line images to 30 Hz (video rate), and (3) adding a 1.0mm inner diameter working channel alongside the tether for distending the lower esophagus with air pressure during endoscopy. All three modifications proved effective for more clearly visualizing the lower esophagus in the first few human subjects. The air channel was especially useful because it did not change tolerability in the first subject for unsedated endoscopy and the air easily removed bubbles obscuring tissue from the field of view. The air provided a non-invasive intervention by stimulating the mechanosensor of the lower esophageal sphincter at the precise time that the TCE was positioned for most informative imaging. All three TCE modifications proved successful for improved visualization of esophageal pathology, such as suspected Barrett's esophagus, without the use of sedation.
LBP based detection of intestinal motility in WCE images
NASA Astrophysics Data System (ADS)
Gallo, Giovanni; Granata, Eliana
2011-03-01
In this research study, a system to support medical analysis of intestinal contractions by processing WCE images is presented. Small intestine contractions are among the motility patterns which reveal many gastrointestinal disorders, such as functional dyspepsia, paralytic ileus, irritable bowel syndrome, bacterial overgrowth. The images have been obtained using the Wireless Capsule Endoscopy (WCE) technique, a patented, video colorimaging disposable capsule. Manual annotation of contractions is an elaborating task, since the recording device of the capsule stores about 50,000 images and contractions might represent only the 1% of the whole video. In this paper we propose the use of Local Binary Pattern (LBP) combined with the powerful textons statistics to find the frames of the video related to contractions. We achieve a sensitivity of about 80% and a specificity of about 99%. The achieved high detection accuracy of the proposed system has provided thus an indication that such intelligent schemes could be used as a supplementary diagnostic tool in endoscopy.
Feasibility of a colon capsule overnight procedure followed by colonoscopy.
Brechmann, T; Schmiegel, W; Klute, L; Rösch, T; Pox, C
2016-02-01
Due to limited acceptance of colonoscopy as diagnostic and screening test alternatives are warranted. Colon capsule endoscopy (CCE) has been shown to be a possible filter test, but because of logistical issues a second bowel preparation is usually required, if consecutive colonoscopy is needed. We therefore evaluated the feasibility of a single bowel preparation for both overnight CCE and (therapeutical) colonoscopy thereafter. Patients from two university hospitals referred to undergo colonoscopy were prospectively included in a dual centre feasibility study. A polyethylene glycol (PEG) based bowel preparation-schedule with ingestion of a colon capsule endoscopy (CCE) at 10pm and subsequent colonoscopy at about 12am on the next day was investigated. The first generation PillCam colon capsule was used with 4 different preparation protocols containing several prokinetics in different compositions (i. e. metoclopramide, erythromycin, sennosoides). The main endpoint was the proportion of patients who completed both CCE and colonoscopy; secondary endpoints were capsule transit times, amount of colon seen on CCE, bowel cleanliness, sensitivity and specifity of CCE and patients' acceptance. 50 patients between 18 and 75 years were included. The sequence of overnight colon capsule endoscopy and colonoscopy was successfully completed in all but one (one refused colonoscopy). The capsule was excreted during recording time in 86 % of examinations, visualization of the complete colon was possible in 60 %, but adequate colon preparation was achieved in only 45 % irrespective of the regimen used. The preparation regimen consisting of a PEG-solution, erythromycin as prokinetic drug followed by PEG-solution as boost showed the largest proportion of adequate preparations. Overall sensitivity and specificity of CCE for polyps of any size were 65 % and 76 %, respectively. 26 of 30 patients (86.7 %) returned the subjective assessment questionnaire. 23 patients (88 %) reported mild to no discomfort or embarrassment during CCE, whereas 15 patients (58 %) did during the preparation procedure. Drinking the purgative solution was the most inconvenient step in 84 % of cases, drinking the boosts during CCE the second inconvenient step (60 %). Overnight CCE-procedure followed by direct capsule-reading is feasible and safe and might avoid repetitive bowel preparation for subsequent colonoscopy. The bowel preparation needs to be improved. © Georg Thieme Verlag KG Stuttgart · New York.
Negreanu, L; Preda, C M; Ionescu, D; Ferechide, D
2015-01-01
Background. A substantial advance in digestive endoscopy that has been made during the last decade is represented by digital chromoendoscopy, which was developed as a quicker and sometimes better alternative to the gold standard of dye spraying. Fujifilm developed a virtual coloration technique called Flexible spectral Imaging Color Enhancement (FICE). FICE provides a better detection of lesions of "minimal" esophagitis, of dysplasia in Barrett's esophagus and of squamous cell esophageal cancer. The use of FICE resulted in an improvement in the visualization of the early gastric cancer, being less invasive, and time consuming than the classic dye methods. Current evidence does not support FICE for screening purposes in colon cancer but it definitely improves characterization of colonic lesions. Its use in inflammatory bowel disease is still controversial and in video capsule endoscopy is considered a substantial progress. Conclusions. The use of FICE endoscopy in routine clinical practice can increase the diagnostic yield and can provide a better characterization of lesions. Future studies to validate its use, the good choice of channels, and the "perfect indications" and to provide common definitions and classifications are necessary.
Software for enhanced video capsule endoscopy: challenges for essential progress.
Iakovidis, Dimitris K; Koulaouzidis, Anastasios
2015-03-01
Video capsule endoscopy (VCE) has revolutionized the diagnostic work-up in the field of small bowel diseases. Furthermore, VCE has the potential to become the leading screening technique for the entire gastrointestinal tract. Computational methods that can be implemented in software can enhance the diagnostic yield of VCE both in terms of efficiency and diagnostic accuracy. Since the appearance of the first capsule endoscope in clinical practice in 2001, information technology (IT) research groups have proposed a variety of such methods, including algorithms for detecting haemorrhage and lesions, reducing the reviewing time, localizing the capsule or lesion, assessing intestinal motility, enhancing the video quality and managing the data. Even though research is prolific (as measured by publication activity), the progress made during the past 5 years can only be considered as marginal with respect to clinically significant outcomes. One thing is clear-parallel pathways of medical and IT scientists exist, each publishing in their own area, but where do these research pathways meet? Could the proposed IT plans have any clinical effect and do clinicians really understand the limitations of VCE software? In this Review, we present an in-depth critical analysis that aims to inspire and align the agendas of the two scientific groups.
Multicenter comparison of double-balloon enteroscopy and spiral enteroscopy.
Rahmi, Gabriel; Samaha, Elia; Vahedi, Kouroche; Ponchon, Thierry; Fumex, Fabien; Filoche, Bernard; Gay, Gerard; Delvaux, Michel; Lorenceau-Savale, Camille; Malamut, Georgia; Canard, Jean-Marc; Chatellier, Gilles; Cellier, Christophe
2013-06-01
Spiral enteroscopy is a novel technique for small bowel exploration. The aim of this study is to compare double-balloon and spiral enteroscopy in patients with suspected small bowel lesions. Patients with suspected small bowel lesion diagnosed by capsule endoscopy were prospectively included between September 2009 and December 2010 in five tertiary-care academic medical centers. After capsule endoscopy, 191 double-balloon enteroscopy and 50 spiral enteroscopies were performed. Indications were obscure gastrointestinal bleeding in 194 (80%) of cases. Lesions detected by capsule endoscopy were mainly angioectasia. Double-balloon and spiral enteroscopy resulted in finding one or more lesions in 70% and 75% of cases, respectively. The mean diagnosis procedure time and the average small bowel explored length during double-balloon and spiral enteroscopy were, respectively, 60 min (45-80) and 55 min (45-80) (P=0.74), and 200 cm (150-300) and 220 cm (200-300) (P=0.13). Treatment during double-balloon and spiral enteroscopy was possible in 66% and 70% of cases, respectively. There was no significant major procedure-related complication. Spiral enteroscopy appears as safe as double-balloon enteroscopy for small bowel exploration with a similar diagnostic and therapeutic yield. Comparison between the two procedures in terms of duration and length of small bowel explored is slightly in favor of spiral enteroscopy but not significantly. © 2013 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.
Lee, W C; Yeh, Y C; Lacy, B E; Pandolfino, J E; Brill, J V; Weinstein, M L; Carlson, A M; Williams, M J; Wittek, M R; Pashos, C L
2008-05-01
Current guidelines recommend the use of pH monitoring to confirm the diagnosis of acid reflux in patients with a normal endoscopy. This analysis evaluated the financial impact of pH monitoring with the wireless pH capsule on a managed care organization (MCO) in the United States. A decision model was constructed to project total 1-year costs to manage GERD symptoms with and without the adoption of wireless pH capsules in a hypothetical MCO with 10 000 eligible adult enrollees, of whom 600 presented with GERD-like symptoms. Costs of GERD diagnosis, treatment, and symptom management for those in whom a GERD diagnosis was ruled out by pH monitoring were assessed. The incremental per-member-per-month (PMPM) and per-treated-member-per-month (PTMPM) costs were the primary outcomes. Data sources included literature, expert input, and standardized fee schedules. An increase of 10 percentage points in the use of pH monitoring with wireless pH capsules yielded incremental PMPM and PTMPM costs of $0.029 and $0.481, respectively. The costs of proton pump inhibitor (PPI) therapy to the plan dropped to $236,363 from $238,086, while increases were observed in pH monitoring (from $16 739 to $21 973) and non-GERD therapy costs (from $1392 to $1740). The results were sensitive to the percentage of patients requiring repeat endoscopy before wireless pH monitoring and the cost of PPIs. Timely and increased use of pH monitoring as recommended in published guidelines leads to less unnecessary use of PPIs with a modest budgetary impact on health plans.
... attached to your abdomen. Each patch contains an antenna with wires that connect to a recorder. Some ... your waist. The camera sends images to an antenna on your abdomen, which feeds the data to ...
Colon Capsule Endoscopy: Where Are We and Where Are We Going
Han, Yoo Min; Im, Jong Pil
2016-01-01
Colon capsule endoscopy (CCE) is a noninvasive technique for diagnostic imaging of the colon. It does not require air inflation or sedation and allows minimally invasive and painless colonic evaluation. The role of CCE is rapidly evolving; for example, for colorectal screening (colorectal cancer [CRC]) in average-risk patients, in patients with an incomplete colonoscopy, in patients refusing a conventional colonoscopy, and in patients with contraindications for conventional colonoscopy. In this paper, we comprehensively review the technical characteristics and procedure of CCE and compare CCE with conventional methods such as conventional colonoscopy or computed tomographic colonography. Future expansion of CCE in the area of CRC screening for the surveillance of polyps and adenomatous lesions and for assessment of inflammatory bowel disease is also discussed. PMID:27653441
Effects of empty bins on image upscaling in capsule endoscopy
NASA Astrophysics Data System (ADS)
Rukundo, Olivier
2017-07-01
This paper presents a preliminary study of the effect of empty bins on image upscaling in capsule endoscopy. The presented study was conducted based on results of existing contrast enhancement and interpolation methods. A low contrast enhancement method based on pixels consecutiveness and modified bilinear weighting scheme has been developed to distinguish between necessary empty bins and unnecessary empty bins in the effort to minimize the number of empty bins in the input image, before further processing. Linear interpolation methods have been used for upscaling input images with stretched histograms. Upscaling error differences and similarity indices between pairs of interpolation methods have been quantified using the mean squared error and feature similarity index techniques. Simulation results demonstrated more promising effects using the developed method than other contrast enhancement methods mentioned.
Small bowel endoluminal imaging (capsule and enteroscopy).
Murino, Alberto; Despott, Edward J
2017-04-01
Over the last 16 years, the disruptive technologies of small bowel capsule endoscopy and device-assisted enteroscopy have revolutionised endoluminal imaging and minimally invasive therapy of the small bowel. Further technological developments continue to expand their indications and use. This brief review highlights the state-of-the-art in this arena and aims to summarise the current and potential future role of these technologies in clinical practice.
Towards active capsular endoscopy: preliminary results on a legged platform.
Menciassi, Arianna; Stefanini, Cesare; Orlandi, Giovanni; Quirini, Marco; Dario, Paolo
2006-01-01
This paper illustrates the problem of active locomotion in the gastrointestinal tract for endoscopic capsules. Authors analyze the problem of locomotion in unstructured, flexible and tubular environments and explain the reasons leading to the selection of a legged system. They present a theoretical simulation of legged capsule locomotion, which is used to define the optimal parameters for capsule design and gait selection. Finally, a legged capsule--about 3 cm3 in volume--is presented; it consists of 4 back legs whose actuation is achieved thanks to a miniaturized DC brushless motor. In vitro tests demonstrate good performance in terms of achievable speed (92 mm/min).
Symptomatic retention of the Agile® patency capsule.
Egea Valenzuela, Juan; Estrella Díez, Esther; Alberca de Las Parras, Fernando
2017-06-01
The Agile® capsule has shown to be useful when evaluating the patency of the small bowel in patients prior to capsule endoscopy studies. It is a safe tool and a low rate of complications have been reported, highlighting symptomatic retention, although references in literature are scarce and it is only observed in 1.2% of the procedures. We present the case of a symptomatic retention of this device in a patient with previously known colonic Crohn's disease in who a small bowel study was indicated and was sent for prior patency test.
Wireless endoscopy in 2020: Will it still be a capsule?
Koulaouzidis, Anastasios; Iakovidis, Dimitris K; Karargyris, Alexandros; Rondonotti, Emanuele
2015-01-01
Currently, the major problem of all existing commercial capsule devices is the lack of control of movement. In the future, with an interface application, the clinician will be able to stop and direct the device into points of interest for detailed inspection/diagnosis, and therapy delivery. This editorial presents current commercially-available new designs, European projects and delivery capsule and gives an overview of the progress required and progress that will be achieved -according to the opinion of the authors- in the next 5 year leading to 2020. PMID:25954085
Farnbacher, Michael J; Krause, Horst H; Hagel, Alexander F; Raithel, Martin; Neurath, Markus F; Schneider, Thomas
2014-03-01
OBJECTIVE. Colon capsule endoscopy (CCE) proved to be highly sensitive in detection of colorectal polyps (CP). Major limitation is the time-consuming video reading. The aim of this prospective, double-center study was to assess the theoretical time-saving potential and its possible impact on the reliability of "QuickView" (QV), in the presentation of CP as compared to normal mode (NM). METHODS. During NM reading of 65 CCE videos (mean patient´s age 56 years), all frames showing CPs were collected and compared to the number of frames presented by QV at increasing QV settings (10, 20, ... 80%). Reliability of QV in presenting polyps <6 mm and ≥6 mm (significant polyp), and identifying patients for subsequent therapeutic colonoscopy, capsule egestion rate, cleansing level, and estimated time-saving potential were assessed. RESULTS. At a 30% QV setting, the QV video presented 89% of the significant polyps and 86% of any polyps with ≥1 frame (per-polyp analysis) identified in NM before. At a 10% QV setting, 98% of the 52 patients with significant polyps could be identified (per-patient analysis) by QV video analysis. Capsule excretion rate was 74% and colon cleanliness was adequate in 85%. QV´s presentation rate correlates to the QV setting, the polyp size, and the number of frames per finding. CONCLUSIONS. Depending on its setting, the reliability of QV in presenting CP as compared to NM reading is notable. However, if no significant polyp is presented by QV, NM reading must be performed afterwards. The reduction of frames to be analyzed in QV might speed up identification of candidates for therapeutic colonoscopy.
Matsuura, Mizue; Inamori, Masahiko; Inou, Yumi; Kanoshima, Kenji; Higurashi, Takuma; Ohkubo, Hidenori; Iida, Hiroshi; Endo, Hiroki; Nonaka, Takashi; Kusakabe, Akihiko; Maeda, Shin; Nakajima, Atsushi
2017-06-01
Lubiprostone has been reported to be an anti-constipation drug. The aim of the study was to investigate the usefulness of lubiprostone both for bowel preparation and as a propulsive agent in small bowel endoscopy. This was a double-blind, placebo-controlled, 2-way crossover study of subjects who volunteered to undergo capsule endoscopy (CE). A total of 20 subjects (16 male and 4 female volunteers) were randomly assigned to receive a 24-μg tablet of lubiprostone 120 minutes prior to capsule ingestion for CE (L regimen), or a placebo tablet 120 minutes prior to capsule ingestion for CE (P regimen). Main outcome was gastric transit time (GTT) and small-bowel transit time (SBTT). Secondary outcome was adequacy of small-bowel cleansing and the fluid score in the small bowel. The quality of the capsule endoscopic images and fluid in the small bowel were assessed on 5-point scale. The capsule passed into the small bowel in all cases. Median GTT was 57.3 (3 - 221) minutes for the P regimen and 61.3 (10 - 218) minutes for the L regimen ( P = 0.836). Median SBTT was 245.0 (164 - 353) minutes for the P regimen and 228.05 (116 - 502) minutes for the L regimen ( P = 0.501). The image quality score in the small bowel was 3.05 ± 1.08 for the P regimen and 3.80 ± 0.49 for the L regimen ( P < 0.001). The fluid score in the small bowel was 2.04 ± 1.58 for the P regimen and 2.72 ± 1.43 for the L regimen ( P < 0.001). There was a significant difference between the 2 regimens with regard to image quality. The fluid score was more plentiful for the L regimen than for the P regimen. There were no cases of capsule retention or serious adverse events in this study. Our study showed that use of lubiprostone prior to CE significantly improved visualization of the small bowel during CE as a result of inducing fluid secretion into the small bowel.
Electrowetting-based liquid lenses for endoscopy
NASA Astrophysics Data System (ADS)
Kuiper, S.
2011-03-01
In endoscopy there is a need for cameras with adjustable focus. In flexible and capsule endoscopes conventional focus systems are not suitable, because of restrictions in diameter and lens displacement range. In this paper it is shown that electrowetting-based variable-focus liquid lenses can provide a solution. A theoretical comparison is made between displacing and deforming lenses, and a demonstrator was built to prove the optical feasibility of focusing with liquid lenses in endoscopes.
Sullivan, Louise M; Kehoe, Joseph J; Barry, Lillian; Buckley, Martin J M; Shanahan, Fergus; Mok, K H; Brodkorb, André
2014-08-28
In the present study, structural changes in the milk protein α-lactalbumin (α-LA) and its proteolysis were investigated for the potential formation of protein-fatty acid complexes during in vivo gastric digestion. Capsule endoscopy allowed visualisation of the digestion of the test drinks, with nasogastric tubes allowing sampling of the gastric contents. A total of ten healthy volunteers had nasogastric tubes inserted into the stomach and ingested test drinks containing 50 g/l of sucrose and 25 g/l of α-LA with and without 4 g/l of oleic acid (OA). The samples of gastric contents were collected for analysis at 3 min intervals. The results revealed a rapid decrease in the pH of the stomach of the subjects. The fasting pH of 2·31 (SD 1·19) increased to a pH maxima of pH 6·54 (SD 0·29) after ingestion, with a subsequent decrease to pH 2·22 (SD 1·91) after 21 min (n 8). Fluorescence spectroscopy and Fourier transform IR spectroscopy revealed partial protein unfolding, coinciding with the decrease in pH below the isoelectric point of α-LA. The activity of pepsin in the fasting state was found to be 39 (SD 12) units/ml of gastric juice. Rapid digestion of the protein occurred: after 15 min, no native protein was detected using SDS-PAGE; HPLC revealed the presence of small amounts of native protein after 24 min of gastric digestion. Mirocam® capsule endoscopy imaging and video clips (see the online supplementary material) revealed that gastric peristalsis resulted in a heterogeneous mixture during gastric digestion. Unfolding of α-LA was observed during gastric transit; however, there was no evidence of a cytotoxic complex being formed between α-LA and OA.
Kim, Hee Man; Yang, Sungwook; Kim, Jinseok; Park, Semi; Cho, Jae Hee; Park, Jeong Youp; Kim, Tae Song; Yoon, Eui-Sung; Song, Si Young; Bang, Seungmin
2010-08-01
Capsule endoscopy that could actively move and approach a specific site might be more valuable for the diagnosis or treatment of GI diseases. We tested the performance of active locomotion of a novel wired capsule endoscope with a paddling-based locomotion mechanism, using 3 models: a silicone tube, an extracted porcine colon, and a living pig. In vitro, ex vivo, and in vivo experiments in a pig model. Study in an animal laboratory. For the in vitro test, the locomotive capsule was controlled to actively move from one side of a silicone tube to the other by a controller-operated automatic traveling program. The velocity was calculated by following a video recording. We performed ex vivo tests by using an extracted porcine colon in the same manner we performed the in vitro test. In in vivo experiments, the capsule was inserted into the rectum of a living pig under anesthesia, and was controlled to move automatically forward. After 8 consecutive trials, the velocity was calculated. Elapsed time, velocity, and mucosal damage. The locomotive capsule showed stable and active movement inside the lumen both in vitro and ex vivo. The velocity was 60 cm/min in the silicone tube, and 36.8 and 37.5 cm/min in the extracted porcine colon. In the in vivo experiments, the capsule stably moved forward inside the colon of a living pig without any serious complications. The mean velocity was 17 cm/min over 40 cm length. We noted pinpoint erythematous mucosal injuries in the colon. Porcine model experiments, wired capsule endoscope. The novel paddling-based locomotive capsule endoscope performed fast and stable movement in a living pig colon with consistent velocity. Further investigation is necessary for practical use in humans. Copyright 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Small bowel endoluminal imaging (capsule and enteroscopy)
Murino, Alberto
2017-01-01
Over the last 16 years, the disruptive technologies of small bowel capsule endoscopy and device-assisted enteroscopy have revolutionised endoluminal imaging and minimally invasive therapy of the small bowel. Further technological developments continue to expand their indications and use. This brief review highlights the state-of-the-art in this arena and aims to summarise the current and potential future role of these technologies in clinical practice. PMID:28839900
Design and control of 2-axis tilting actuator for endoscope using ionic polymer metal composites
NASA Astrophysics Data System (ADS)
Kim, Sung-Joo; Kim, Chul-Jin; Park, No-Cheol; Yang, Hyun-Seok; Park, Young-Pil
2009-03-01
In field of endoscopy, in order to overcome limitation in conventional endoscopy, capsule endoscope has been developed and has been recently applied in medical field in hospital. However, since capsule endoscope moves passively through GI tract by peristalsis, it is not able to control direction of head including camera. It is possible to miss symptoms of disease. Therefore, in this thesis, 2-Axis Tilting Actuator for Endoscope, based on Ionic Polymer Metal Composites (IPMC), is presented. In order to apply to capsule endoscope, the actuator material should satisfy a size, low energy consumption and low working voltage. Since IPMC is emerging material that exhibits a large bending deflection at low voltage, consume low energy and it can be fabricated in any size or any shape, IPMC are selected as an actuator. The system tilts camera module of endoscope to reduce invisible area of the intestines and a goal of tilting angle is selected to be an angle of 5 degrees for each axis. In order to control tiling angle, LQR controller and the full order observer is designed.
Thermo-mechanical actuator-based miniature tagging module for localization in capsule endoscopy
NASA Astrophysics Data System (ADS)
Chandrappan, Jayakrishnan; Ruiqi, Lim; Su, Nandar; Yen Yi, Germaine Hoe; Vaidyanathan, Kripesh
2011-04-01
Capsule endoscopy is a frontline medical diagnostic tool for the gastro intestinal tract disorders. During diagnosis, efficient localization techniques are essential to specify a pathological area that may require further diagnosis or treatment. This paper presents the development of a miniature tagging module that relies on a novel concept to label the region of interest and has the potential to integrate with a capsule endoscope. The tagging module is a compact thermo-mechanical actuator loaded with a biocompatible micro tag. A low power microheater attached to the module serves as the thermal igniter for the mechanical actuator. At optimum temperature, the actuator releases the micro tag instantly and penetrates the mucosa layer of a GI tract, region of interest. Ex vivo animal trials are conducted to verify the feasibility of the tagging module concept. X-ray imaging is used to detect the location of the micro tag embedded in the GI tract wall. The method is successful, and radiopaque micro tags can provide valuable pre-operative position information on the infected area to facilitate further clinical procedures.
Capsule-odometer: a concept to improve accurate lesion localisation.
Karargyris, Alexandros; Koulaouzidis, Anastasios
2013-09-21
In order to improve lesion localisation in small-bowel capsule endoscopy, a modified capsule design has been proposed incorporating localisation and - in theory - stabilization capabilities. The proposed design consists of a capsule fitted with protruding wheels attached to a spring-mechanism. This would act as a miniature odometer, leading to more accurate lesion localization information in relation to the onset of the investigation (spring expansion e.g., pyloric opening). Furthermore, this capsule could allow stabilization of the recorded video as any erratic, non-forward movement through the gut is minimised. Three-dimensional (3-D) printing technology was used to build a capsule prototype. Thereafter, miniature wheels were also 3-D printed and mounted on a spring which was attached to conventional capsule endoscopes for the purpose of this proof-of-concept experiment. In vitro and ex vivo experiments with porcine small-bowel are presented herein. Further experiments have been scheduled.
Wireless Insufflation of the Gastrointestinal Tract
Battaglia, Santina; Smith, Byron F.; Ciuti, Gastone; Gerding, Jason; Menciassi, Arianna; Obstein, Keith L.; Valdastri, Pietro; Webster, Robert J.
2013-01-01
Despite clear patient experience advantages, low specificity rates have thus far prevented swallowable capsule endoscopes from replacing traditional endoscopy for diagnosis of colon disease. One explanation for this is that capsule endoscopes lack the ability to provide insufflation, which traditional endoscopes use to distend the intestine for a clear view of the internal wall. To provide a means of insufflation from a wireless capsule platform, in this paper we use biocompatible effervescent chemical reactions to convert liquids and powders carried onboard a capsule into gas. We experimentally evaluate the quantity of gas needed to enhance capsule visualization and locomotion, and determine how much gas can be generated from a given volume of reactants. These experiments motivate the design of a wireless insufflation capsule, which is evaluated in ex vivo experiments. These experiments illustrate the feasibility of enhancing visualization and locomotion of endoscopic capsules through wireless insufflation. PMID:23212312
Evaluation of friction enhancement through soft polymer micro-patterns in active capsule endoscopy
NASA Astrophysics Data System (ADS)
Buselli, Elisa; Pensabene, Virginia; Castrataro, Piero; Valdastri, Pietro; Menciassi, Arianna; Dario, Paolo
2010-10-01
Capsule endoscopy is an emerging field in medical technology. Despite very promising innovations, some critical issues are yet to be addressed, such as the management and possible exploitation of the friction in the gastrointestinal environment in order to control capsule locomotion more actively. This paper presents the fabrication and testing of bio-inspired polymeric micro-patterns, which are arrays of cylindrical pillars fabricated via soft lithography. The aim of the work is to develop structures that enhance the grip between an artificial device and the intestinal tissue, without injuring the mucosa. In fact, the patterns are intended to be mounted on microfabricated legs of a capsule robot that is able to move actively in the gastrointestinal tract, thus improving the robot's traction ability. The effect of micro-patterned surfaces on the leg-slipping behaviour on colon walls was investigated by considering both different pillar dimensions and the influence of tissue morphology. Several in vitro tests on biological samples demonstrated that micro-patterns of pillars made from a soft polymer with an aspect ratio close to 1 enhanced friction by 41.7% with regard to flat surfaces. This work presents preliminary modelling of the friction and adhesion forces in the gastrointestinal environment and some design guidelines for endoscopic devices.
Portable wireless power transmission system for video capsule endoscopy.
Zhiwei, Jia; Guozheng, Yan; Bingquan, Zhu
2014-10-01
Wireless power transmission is considered a practical way of overcoming the power shortage of wireless capsule endoscopy (VCE). However, most patients cannot tolerate the long hours of lying in a fixed transmitting coil during diagnosis. To develop a portable wireless power transmission system for VCE, a compact transmitting coil and a portable inverter circuit driven by rechargeable batteries are proposed. The couple coils, optimized considering the stability and safety conditions, are 28 turns of transmitting coil and six strands of receiving coil. The driven circuit is designed according to the portable principle. Experiments show that the integrated system could continuously supply power to a dual-head VCE for more than 8 h at a frame rate of 30 frames per second with resolution of 320 × 240. The portable VCE exhibits potential for clinical applications, but requires further improvement and tests.
Optimal Bowel Preparation for Video Capsule Endoscopy
Song, Hyun Joo; Moon, Jeong Seop; Shim, Ki-Nam
2016-01-01
During video capsule endoscopy (VCE), several factors, such as air bubbles, food material in the small bowel, and delayed gastric and small bowel transit time, influence diagnostic yield, small bowel visualization quality, and cecal completion rate. Therefore, bowel preparation before VCE is as essential as bowel preparation before colonoscopy. To date, there have been many comparative studies, consensus, and guidelines regarding different kinds of bowel cleansing agents in bowel preparation for small bowel VCE. Presently, polyethylene glycol- (PEG-) based regimens are given primary recommendation. Sodium picosulphate-based regimens are secondarily recommended, as their cleansing efficacy is less than that of PEG-based regimens. Sodium phosphate as well as complementary simethicone and prokinetics use are considered. In this paper, we reviewed previous studies regarding bowel preparation for small bowel VCE and suggested optimal bowel preparation of VCE. PMID:26880894
Li, Baopu; Meng, Max Q-H
2012-05-01
Tumor in digestive tract is a common disease and wireless capsule endoscopy (WCE) is a relatively new technology to examine diseases for digestive tract especially for small intestine. This paper addresses the problem of automatic recognition of tumor for WCE images. Candidate color texture feature that integrates uniform local binary pattern and wavelet is proposed to characterize WCE images. The proposed features are invariant to illumination change and describe multiresolution characteristics of WCE images. Two feature selection approaches based on support vector machine, sequential forward floating selection and recursive feature elimination, are further employed to refine the proposed features for improving the detection accuracy. Extensive experiments validate that the proposed computer-aided diagnosis system achieves a promising tumor recognition accuracy of 92.4% in WCE images on our collected data.
Wu, Liucheng; Cao, Yunfei; Liao, Cun; Huang, Jiahao; Gao, Feng
2011-02-01
The value of supplemental use of Simethicone in endoscopy including capsule endoscopy (CE), colonoscopy and esophagogastroduodenoscopy is not addressed and is controversial. A systematic review and meta-analysis of randomized controlled studies on the use of Simethicone for endoscopy were carried out. The effects of this preparation on the following endpoints were examined: small bowel visualization quality (SBVQ), completion rate, gastric transit time, small bowel transit time, diagnostic yield, efficacy of bowel preparation, degree of air bubbles and duration time. A total of 13 studies were eligible in this meta-analysis; 4 studies comparing purgative or fasting plus Simethicone with purgative or fasting alone for capsule endoscopy were identified. For patients who had supplemental Simethicone before CE, the SBVQ was significantly better ([odds ratio] OR = 2.84, 95% CI: 1.74-4.65, p = 0.00), and the completion rate was comparable (OR = 0.80, 95% CI: 0.44-1.44, p = 0.454). Also, 7 studies comparing purgative plus Simethicone with purgative alone for colonoscopy were identified. For patients who had supplemental Simethicone before colonoscopy, the efficacy of colon preparation was comparable (OR = 2.06, 95% CI: 0.56-7.53, p = 0.27), but the air bubbles were significantly decreased (OR = 39.32, 95% CI: 11.38-135.86, p = 0.00). Supplemental use of Simethicone before endoscopy improves the SBVQ, especially for patients who received no purgative, but does not affect the CE completion rate. It decreases air bubbles in the colonic lumen, but does not improve bowel preparation. And its effect on diagnostic yield remains controversial.
Virtual chromoendoscopy can be a useful software tool in capsule endoscopy.
Duque, Gabriela; Almeida, Nuno; Figueiredo, Pedro; Monsanto, Pedro; Lopes, Sandra; Freire, Paulo; Ferreira, Manuela; Carvalho, Rita; Gouveia, Hermano; Sofia, Carlos
2012-05-01
capsule endoscopy (CE) has revolutionized the study of small bowel. One major drawback of this technique is that we cannot interfere with image acquisition process. Therefore, the development of new software tools that could modify the images and increase both detection and diagnosis of small-bowel lesions would be very useful. The Flexible Spectral Imaging Color Enhancement (FICE) that allows for virtual chromoendoscopy is one of these software tools. to evaluate the reproducibility and diagnostic accuracy of the FICE system in CE. this prospective study involved 20 patients. First, four physicians interpreted 150 static FICE images and the overall agreement between them was determined using the Fleiss Kappa Test. Second, two experienced gastroenterologists, blinded to each other results, analyzed the complete 20 video streams. One interpreted conventional capsule videos and the other, the CE-FICE videos at setting 2. All findings were reported, regardless of their clinical value. Non-concordant findings between both interpretations were analyzed by a consensus panel of four gastroenterologists who reached a final result (positive or negative finding). in the first arm of the study the overall concordance between the four gastroenterologists was substantial (0.650). In the second arm, the conventional mode identified 75 findings and the CE-FICE mode 95. The CE-FICE mode did not miss any lesions identified by the conventional mode and allowed the identification of a higher number of angiodysplasias (35 vs 32), and erosions (41 vs. 24). there is reproducibility for the interpretation of CE-FICE images between different observers experienced in conventional CE. The use of virtual chromoendoscopy in CE seems to increase its diagnostic accuracy by highlighting small bowel erosions and angiodysplasias that weren´t identified by the conventional mode.
Design and fabrication of a magnetic propulsion system for self-propelled capsule endoscope.
Gao, Mingyuan; Hu, Chengzhi; Chen, Zhenzhi; Zhang, Honghai; Liu, Sheng
2010-12-01
This paper investigates design, modeling, simulation, and control issues related to self-propelled endoscopic capsule navigated inside the human body through external magnetic fields. A novel magnetic propulsion system is proposed and fabricated, which has great potential of being used in the field of noninvasive gastrointestinal endoscopy. Magnetic-analysis model is established and finite-element simulations as well as orthogonal design are performed for obtaining optimized mechanical and control parameters for generating appropriate external magnetic field. Simulated intestinal tract experiments are conducted, demonstrating controllable movement of the capsule under the developed magnetic propulsion system.
Caunedo-Álvarez, Ángel; Romero-Vazquez, Javier; Herrerias-Gutierrez, Juan M
2008-01-01
Small bowel strictures can be missed by current diagnostic methods. The Patency capsule is a new non-endoscopic dissolvable capsule which has as an objective of checking the patency of digestive tract, in a non-invasive manner. The available clinical trials have demonstrated that the Patency© capsule is a good tool for assessment of the functional patency of the small bowel, and it allows identification of those patients who can safely undergo a capsule endoscopy, despite clinical and radiographic evidence of small-bowel obstruction. Some cases of intestinal occlusion have been reported with the Patency© capsule, four of them needed surgery. So, a new capsule with two timer plugs (Agile© capsule) has been recently developed in order to minimize the risk of occlusion. This new device stars its dissolution process earlier (30 h after ingestion) and its two timer plugs have been designed to begin the disintegration even when the device is blocked in a tight stricture. PMID:18785278
A locomotion mechanism with external magnetic guidance for active capsule endoscope.
Wang, Xiaona; Meng, Max Q H; Chen, Xijun
2010-01-01
Gastrointestinal (GI) disorder is one of the most common diseases in human body. The swallowable wireless capsule endoscopy has been proved to be a convenient, painless and effective way to examine the whole GI tract. However, lack of motion control makes the movement of the capsule substantially random, resulting in missing diagnosis. In this paper, a locomotion mechanism is developed for the next-generation active capsule endoscope. An internal actuator integrated on-board the capsule is designed to provide driving force and improve the dexterity. A small permanent magnet enclosed inside the capsule interacts with an external magnetic field to control the capsule's orientation and offer extra driving force. This mechanism avoids sophisticated and bulky control system and reduces power consumption inside the capsule. Ex-vivo experimental results showed that it can make a controllable movement inside the porcine large intestine. The mechanism also has the potential to be a platform for further development, such as devices of operations, spraying medicine, biopsy etc.
Yung, Diana; Douglas, Sarah; Hobson, Anthony R; Giannakou, Andry; Plevris, John N; Koulaouzidis, Anastasios
2016-04-01
SmartPill(®) (Given Imaging Corp.,Yoqneam,Israel) is an ingestible, non-imaging capsule that records physiological data including contractions and pH throughout the gastrointestinal tract. There are scarce data looking at SmartPill(®) assessment of patients with known/suspected small-bowel Crohn's Disease (CD). This pilot study aims to investigate feasibility and safety of SmartPill(®) to assess gut motility in this group. Over 1 year, patients with known/suspected CD, referred for small-bowel capsule endoscopy (SBCE), were invited to participate and 12 were recruited (7 female, 5 male, mean age 44.2 ± 16.6 years). They underwent hydrogen breath test to exclude small-bowel bacterial overgrowth, patency capsule (Agile(®)), and provided stool samples for fecal calprotectin (FC). Patients ingested PillCam(®)SB2 and SmartPill(®) 4 hours apart. Using unpublished data, 33 healthy controls also were identified for the study. P < 0.05 was considered statistically significant. Of the 12 patients enrolled, 10 underwent complete Smartpill(®) examination (1 stomach retention, 1 dropout). Pillcam(®) was complete in 10 (1 dropout, 1 stomach retention). Mean fecal calprotectin was 340 ± 307.71 mcg/g. The study group had longer transit times and lower gut motility index than did the controls. The difference in motility appears to be statistically significant (P < 0.05). Longer transit times for SmartPill(®) (not statistically significant) may have been due to different specifications between the capsules. Limitations included transient Smartpill(®) signal loss (5/10 studies). This is the first pilot to attempt combining SBCE and SmartPill(®) to assess small-bowel CD. Data on motility in CD are scarce. Multimodal information can provide a clearer clinical picture. Despite concerns about capsule retention in CD patients, SmartPill(®) seems safe for use if a patency capsule is employed beforehand.
Sung, Joseph Jy; Chiu, Philip Cy; Chan, Francis K L; Lau, James Yw; Goh, Khean-Lee; Ho, Lawrence Hy; Jung, Hwoon-Young; Sollano, Jose D; Gotoda, Takuji; Reddy, Nageshwar; Singh, Rajvinder; Sugano, Kentaro; Wu, Kai-Chun; Wu, Chun-Yin; Bjorkman, David J; Jensen, Dennis M; Kuipers, Ernst J; Lanas, Angel
2018-04-24
Non-variceal upper gastrointestinal bleeding remains an important emergency condition, leading to significant morbidity and mortality. As endoscopic therapy is the 'gold standard' of management, treatment of these patients can be considered in three stages: pre-endoscopic treatment, endoscopic haemostasis and post-endoscopic management. Since publication of the Asia-Pacific consensus on non-variceal upper gastrointestinal bleeding (NVUGIB) 7 years ago, there have been significant advancements in the clinical management of patients in all three stages. These include pre-endoscopy risk stratification scores, blood and platelet transfusion, use of proton pump inhibitors; during endoscopy new haemostasis techniques (haemostatic powder spray and over-the-scope clips); and post-endoscopy management by second-look endoscopy and medication strategies. Emerging techniques, including capsule endoscopy and Doppler endoscopic probe in assessing adequacy of endoscopic therapy, and the pre-emptive use of angiographic embolisation, are attracting new attention. An emerging problem is the increasing use of dual antiplatelet agents and direct oral anticoagulants in patients with cardiac and cerebrovascular diseases. Guidelines on the discontinuation and then resumption of these agents in patients presenting with NVUGIB are very much needed. The Asia-Pacific Working Group examined recent evidence and recommends practical management guidelines in this updated consensus statement. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Manatsathit, Wuttiporn; Khrucharoen, Usah; Jensen, Dennis M.; Hines, O. Joe; Kovacs, Thomas; Ohning, Gordon; Jutabha, Rome; Ghassemi, Kevin; Dulai, Gareth S.; Machicado, Gustavo
2017-01-01
Background To evaluate roles of intraoperative endoscopy (IOE) in management of severe obscure GI bleeding (OGIB) before vs. after introduction of video capsule endoscopy (VCE) and deep enteroscopy (DE). Methods We retrospectively reviewed prospectively collected data of patients undergoing IOE for severe OGIB in a tertiary referral center. Results 52 patients had laparotomy/IOE for OGIB, 11 pre and 41 post VCE/DE eras. In the pre VCE/DE era, 36.4% (4/11) had preoperative presumptive diagnoses while in the post VCE/DE era presumptive diagnoses were made in 48.8% (20/41) (p= 0.18). Preoperative evaluation led to correct diagnoses in 18.2% (2/11) in the pre and 51.2% (21/41) in the post VCE/DE era (p=0.09). Vascular lesions and ulcers were the most common diagnoses, but rebleeding was common. No rebleeding was found among patients with tumors, Meckel's diverticulum, and aortoenteric fistula. Conclusions Presumptive diagnoses in the post VCE/DE era were usually accurate. If VCE or DE are negative, the probability of negative IOE is high. Patients with tumors and Meckel's diverticulum were the best candidates for IOE. PMID:28629608
Global-constrained hidden Markov model applied on wireless capsule endoscopy video segmentation
NASA Astrophysics Data System (ADS)
Wan, Yiwen; Duraisamy, Prakash; Alam, Mohammad S.; Buckles, Bill
2012-06-01
Accurate analysis of wireless capsule endoscopy (WCE) videos is vital but tedious. Automatic image analysis can expedite this task. Video segmentation of WCE into the four parts of the gastrointestinal tract is one way to assist a physician. The segmentation approach described in this paper integrates pattern recognition with statiscal analysis. Iniatially, a support vector machine is applied to classify video frames into four classes using a combination of multiple color and texture features as the feature vector. A Poisson cumulative distribution, for which the parameter depends on the length of segments, models a prior knowledge. A priori knowledge together with inter-frame difference serves as the global constraints driven by the underlying observation of each WCE video, which is fitted by Gaussian distribution to constrain the transition probability of hidden Markov model.Experimental results demonstrated effectiveness of the approach.
Togashi, Kazutomo; Fujita, Tomoki; Utano, Kenichi; Waga, Eriko; Katsuki, Shinichi; Isohata, Noriyuki; Endo, Shungo; Lefor, Alan K.
2015-01-01
Background and study aims: Sodium phosphate is a key component of bowel preparation regimen for colon capsule endoscopy (CCE), but may cause serious complications. The aim of this study is to evaluate the use of Gastrografin, substituted for sodium phosphate, in CCE bowel preparation. Patients and methods: In total, 29 patients (median age 64 years; 23 females) underwent CCE, covered by the national health insurance system of Japan. All had a history of laparotomy and/or previously incomplete colonoscopy. On the day before examination, patients ingested 1 L of polyethylene glycol + ascorbic acid with 0.5 L of water in the evening, and again the same laxative on the morning of examination. After capsule ingestion, 50 mL of Gastrografin diluted with 0.9 L of magnesium citrate was administered, and then repeated after 1 hour. Results: The capsule excretion rate was 97 % (28/29). The median colon transit time was 2 hours 45 minutes and rapid transit (< 40 minutes) through the colon occurred in one patient (3.4 %). Bowel cleansing level was adequate in 90 % of patients. The polyp (≥ 6 mm) detection rate was 52 %. Diluted Gastrografin was well tolerated by patients. No adverse events occurred. Conclusion: Gastrografin can be an alternative to sodium phosphate in CCE bowel preparation regimen. PMID:26716132
Stanich, Peter P; Kleinman, Bryan; Porter, Kyle M; Meyer, Marty M
2015-01-01
To investigate the outcomes of video capsule endoscopy (VCE) performed on patients after bariatric and gastric surgery with a focus on delivery method (oral ingestion or endoscopic placement). There is minimal published data regarding the use of VCE in patients after bariatric and gastric surgery and the optimal delivery method is unknown. Retrospective case series of patients with bariatric or gastric surgery undergoing VCE in a tertiary care center over 3 years. Outcomes of interest were completion of the procedure and bowel transit times. Twenty-three patients met study criteria. They underwent 24 VCE in the study period, with 13/16 (81.3%; 95% CI, 54%-96%) completed to the colon after oral ingestion and 5/8 (62.5%; 95% CI, 24%-91%) completed after endoscopic deployment. The median gastric transit time after oral ingestion was <1 minute (IQR, <1 to 99). Median total transit time after oral ingestion was 291 minutes (IQR, 213 to 434) and after endoscopic deployment was 364 minutes (IQR, 233 to >440) (P=0.48). There were no instances of capsule retention. Oral ingestion of VCE resulted in a satisfactory completion rate with rapid gastric transit after bariatric and gastric surgery. There were no capsule retention events. Given this and the favorable risk and cost profile, oral ingestion should be favored over endoscopic placement in this patient population.
Bao, Guanqun; Mi, Liang; Geng, Yishuang; Zhou, Mingda; Pahlavan, Kaveh
2014-01-01
Wireless Capsule Endoscopy (WCE) is progressively emerging as one of the most popular non-invasive imaging tools for gastrointestinal (GI) tract inspection. As a critical component of capsule endoscopic examination, physicians need to know the precise position of the endoscopic capsule in order to identify the position of intestinal disease. For the WCE, the position of the capsule is defined as the linear distance it is away from certain fixed anatomical landmarks. In order to measure the distance the capsule has traveled, a precise knowledge of how fast the capsule moves is urgently needed. In this paper, we present a novel computer vision based speed estimation technique that is able to extract the speed of the endoscopic capsule by analyzing the displacements between consecutive frames. The proposed approach is validated using a virtual testbed as well as the real endoscopic images. Results show that the proposed method is able to precisely estimate the speed of the endoscopic capsule with 93% accuracy on average, which enhances the localization accuracy of the WCE to less than 2.49 cm.
Wireless capsule endoscopy for diagnosis of acute intestinal graft-versus-host disease.
Neumann, Susanne; Schoppmeyer, Konrad; Lange, Thoralf; Wiedmann, Marcus; Golsong, Johannes; Tannapfel, Andrea; Mossner, Joachim; Niederwieser, Dietger; Caca, Karel
2007-03-01
The small intestine is the most common location of intestinal graft-versus-host disease (GVHD). EGD with duodenal biopsies yields the highest diagnostic sensitivity, but the jejunum and ileum are not accessible by regular endoscopy. In contrast, wireless capsule endoscopy (WCE) is a noninvasive imaging procedure offering complete evaluation of the small intestine. The objective was to compare the diagnostic value of EGD, including biopsies, with the results of WCE in patients with acute intestinal symptoms who received allogeneic blood stem cell transplantation and to analyze the appearance and distribution of acute intestinal GVHD lesions in these patients. An investigator-blinded, single-center prospective study. Patients with acute intestinal symptoms after allogeneic stem cell transplantation underwent both EGD and WCE within 24 hours. Clinical data were recorded during 2 months of follow-up. Fourteen consecutive patients with clinical symptoms of acute intestinal GVHD were recruited. In 1 patient, the capsule remained in the stomach and was removed endoscopically. In 7 of 13 patients who could be evaluated, acute intestinal GVHD was diagnosed by EGD with biopsies, but 3 of these would have been missed by EGD alone. In all 7 patients with histologically confirmed acute intestinal GVHD, WCE revealed typical signs of GVHD. Lesions were scattered throughout the small intestine, but were most accentuated in the ileum. This study had a small number of patients. WCE, which is less invasive than EGD with biopsies, showed a comparable sensitivity and a high negative predictive value for diagnosing acute intestinal GVHD. It may be helpful to avoid repeated endoscopic procedures in patients who have undergone stem cell transplantation.
Oliva, Salvatore; Cucchiara, Salvatore; Spada, Cristiano; Hassan, Cesare; Ferrari, Federica; Civitelli, Fortunata; Pagliaro, Giuseppe; Di Nardo, Giovanni
2014-01-01
Small bowel cleansing by capsule endoscopy has never been addressed in children. Randomized controlled trial to evaluate the effect of five bowel preparation regimens on the mucosal visibility surface (as percentage of visualized surface area). Group A: a clear liquid diet for 12 h on the day before; Group B: high volume polyethylene glycol (50 mL/kg, up to 2Lt/die); Group C: low volume polyethylene glycol (25 mL/kg up to 1Lt/die); Group D: 20 mL (376 mg) of oral simethicone; Group E: 25 mL/kg (up to 1Lt/die) of polyethylene glycol solution plus 20 mL (376 mg) of oral simethicone. Overall, 198 patients (53% male, median age 13 years) were enrolled. Preparation regimen visualization scores were 14.1 ± 4.2, 18.9 ± 5.1, 17.8 ± 5.5, 14.9 ± 4.8 and 20.9 ± 4.6 in groups A, B, C, D and E, respectively (P < 0.01). Positive findings were found in 172 cases (87%), but no significant differences were observed in the diagnostic yield and tolerability. Interobserver agreement, k = 0.89 (95% CI 0.83 ± 0.71). This is the first report in children that supports the use of 25 mL/kg (up to 1Lt/die) of polyethylene glycol solution plus 20 mL (376 mg) of oral simethicone as the preparation of choice for capsule endoscopy. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Iakovidis, Dimitris K; Koulaouzidis, Anastasios
2014-11-01
The advent of wireless capsule endoscopy (WCE) has revolutionized the diagnostic approach to small-bowel disease. However, the task of reviewing WCE video sequences is laborious and time-consuming; software tools offering automated video analysis would enable a timelier and potentially a more accurate diagnosis. To assess the validity of innovative, automatic lesion-detection software in WCE. A color feature-based pattern recognition methodology was devised and applied to the aforementioned image group. This study was performed at the Royal Infirmary of Edinburgh, United Kingdom, and the Technological Educational Institute of Central Greece, Lamia, Greece. A total of 137 deidentified WCE single images, 77 showing pathology and 60 normal images. The proposed methodology, unlike state-of-the-art approaches, is capable of detecting several different types of lesions. The average performance, in terms of the area under the receiver-operating characteristic curve, reached 89.2 ± 0.9%. The best average performance was obtained for angiectasias (97.5 ± 2.4%) and nodular lymphangiectasias (96.3 ± 3.6%). Single expert for annotation of pathologies, single type of WCE model, use of single images instead of entire WCE videos. A simple, yet effective, approach allowing automatic detection of all types of abnormalities in capsule endoscopy is presented. Based on color pattern recognition, it outperforms previous state-of-the-art approaches. Moreover, it is robust in the presence of luminal contents and is capable of detecting even very small lesions. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.
De Jonge, Pieter J F; Van Eijck, Brechje C; Geldof, Han; Bekkering, Frank C; Essink-Bot, Marie-Louise; Polinder, Suzanne; Kuipers, Ernst J; Siersema, Peter D
2008-01-01
To assess the accuracy of a new ingestion protocol for capsule endoscopy (CE) in evaluating patients with gastro-oesophageal reflux disease (GORD). Oesophago-gastroduodenoscopy (OGD) was performed 1 week prior to CE. The first 28 subjects swallowed the capsule following the original ingestion protocol (OIP) and the subsequent 30 subjects following a simplified ingestion protocol (SIP). CE videos were reviewed by two independent investigators who were blinded to the OGD findings. Of 48 patients included, 24 were diagnosed with reflux oesophagitis (67% male, mean age 49.5+/-13 years) and 24 with Barrett oesophagus (BO) (88% male, 55.6+/-10 years) by OGD. In addition, 10 asymptomatic healthy controls (50% male, 45.8+/-7.1 years) were included. Oesophageal transit time was faster in patients using the SIP compared to the OIP (126+/-26 s versus 214+/-33; p=0.04). Complete evaluation of the Z-line was possible in 19/28 (68%) of the OIPs compared to 28/30 (93%) of the SIPs (p=0.04). Sensitivity for detecting any oesophageal abnormality was higher in the SIP group than in the OIP group (97% versus 89%; p=0.11). Overall, CE detected oesophagitis in 22/24 patients (sensitivity, 92%; specificity, 88%) and BO in 23/24 patients (sensitivity, 96%; specificity, 91%). Furthermore, 41/44 (93%) preferred CE over OGD and experienced less discomfort and pain during CE. CE is an accurate method for detecting mucosal oesophageal abnormalities. The new ingestion protocol improves the visualization of the Z-line, which is likely to increase the diagnostic yield of CE.
NASA Astrophysics Data System (ADS)
Dimas, George; Iakovidis, Dimitris K.; Karargyris, Alexandros; Ciuti, Gastone; Koulaouzidis, Anastasios
2017-09-01
Wireless capsule endoscopy is a non-invasive screening procedure of the gastrointestinal (GI) tract performed with an ingestible capsule endoscope (CE) of the size of a large vitamin pill. Such endoscopes are equipped with a usually low-frame-rate color camera which enables the visualization of the GI lumen and the detection of pathologies. The localization of the commercially available CEs is performed in the 3D abdominal space using radio-frequency (RF) triangulation from external sensor arrays, in combination with transit time estimation. State-of-the-art approaches, such as magnetic localization, which have been experimentally proved more accurate than the RF approach, are still at an early stage. Recently, we have demonstrated that CE localization is feasible using solely visual cues and geometric models. However, such approaches depend on camera parameters, many of which are unknown. In this paper the authors propose a novel non-parametric visual odometry (VO) approach to CE localization based on a feed-forward neural network architecture. The effectiveness of this approach in comparison to state-of-the-art geometric VO approaches is validated using a robotic-assisted in vitro experimental setup.
Reduction of capsule endoscopy reading times by unsupervised image mining.
Iakovidis, D K; Tsevas, S; Polydorou, A
2010-09-01
The screening of the small intestine has become painless and easy with wireless capsule endoscopy (WCE) that is a revolutionary, relatively non-invasive imaging technique performed by a wireless swallowable endoscopic capsule transmitting thousands of video frames per examination. The average time required for the visual inspection of a full 8-h WCE video ranges from 45 to 120min, depending on the experience of the examiner. In this paper, we propose a novel approach to WCE reading time reduction by unsupervised mining of video frames. The proposed methodology is based on a data reduction algorithm which is applied according to a novel scheme for the extraction of representative video frames from a full length WCE video. It can be used either as a video summarization or as a video bookmarking tool, providing the comparative advantage of being general, unbounded by the finiteness of a training set. The number of frames extracted is controlled by a parameter that can be tuned automatically. Comprehensive experiments on real WCE videos indicate that a significant reduction in the reading times is feasible. In the case of the WCE videos used this reduction reached 85% without any loss of abnormalities.
Engineering Micromechanical Systems for the Next Generation Wireless Capsule Endoscopy
Woods, Stephen; Constandinou, Timothy
2015-01-01
Wireless capsule endoscopy (WCE) enables the detection and diagnosis of inflammatory bowel diseases such as Crohn's disease and ulcerative colitis. However treatment of these pathologies can only be achieved through conventional means. This paper describes the next generation WCE with increased functionality to enable targeted drug delivery in the small intestinal tract. A prototype microrobot fabricated in Nylon 6 is presented which is capable of resisting peristaltic pressure through the deployment of an integrated holding mechanism and delivering targeted therapy. The holding action is achieved by extending an “anchor” spanning a 60.4 mm circumference, for an 11.0 mm diameter WCE. This function is achieved by a mechanism that occupies only 347.0 mm3 volume, including mechanics and actuator. A micropositioning mechanism is described which utilises a single micromotor to radially position and then deploy a needle 1.5 mm outside the microrobot's body to deliver a 1 mL dose of medication to a targeted site. An analysis of the mechanics required to drive the holding mechanism is presented and an overview of microactuators and the state of the art in WCE is discussed. It is envisaged that this novel functionality will empower the next generation of WCE to help diagnose and treat pathologies of the GI tract. PMID:26258143
Olano, Carolina; Pazos, Ximena; Avendaño, Karla; Calleri, Alfonso; Ketzoian, Carlos
2018-06-01
Despite the widespread use of small-bowel capsule endoscopy (CE), there is still limited data on its utility and effectiveness for the diagnosis and management of patients with iron-deficiency anemia (IDA). To assess the diagnostic yield of CE and the factors predicting positive findings in patients with IDA. Patients with unexplained IDA and negative upper and lower endoscopy were included. A positive diagnostic yield was considered when CE diagnosed one or more lesions that could explain the IDA. Sex, age, NSAID consumption, blood transfusion requirement, and ferritin and hemoglobin levels were recorded. In total, 120 CE were included (mean age 58.5 years; F/M 82:38). Mean hemoglobin levels were 9 g/dL and mean ferritin levels were 15.7 ng/mL. Positive findings were present in 50 % of patients. The most frequent was angiodysplasia (45 %). Despite several baseline variables being significantly associated with positive findings, using a logistic regression model, it was verified that male sex (OR 3.93; 95 %CI 1.57 - 9.86), age (OR 1.03; 95 %CI 1.00 - 1.06), and hemoglobin levels (OR 0.73; 95 %CI 0.57 - 0.94) were the variables having an independent effect on the probability of obtaining positive findings. Age older than 50 years (OR 14.05; 95 %CI 1.69 - 116.23) and male sex (OR 3.63; 95 %CI 1.29 - 10.17) were the variables which increased the risk of diagnosing angiodysplasia. CE is a useful technique in patients with IDA. To improve its yield, it is necessary to select patients carefully. Male sex, older age, and low hemoglobin levels were associated with a risk of positive finding in this group of patients. The risk of diagnosing angiodysplasia increased with male sex and older age.
Levesque, Barrett G; Cipriano, Lauren E; Chang, Steven L; Lee, Keane K; Owens, Douglas K; Garber, Alan M
2010-03-01
The cost effectiveness of alternative approaches to the diagnosis of small-bowel Crohn's disease is unknown. This study evaluates whether computed tomographic enterography (CTE) is a cost-effective alternative to small-bowel follow-through (SBFT) and whether capsule endoscopy is a cost-effective third test in patients in whom a high suspicion of disease remains after 2 previous negative tests. A decision-analytic model was developed to compare the lifetime costs and benefits of each diagnostic strategy. Patients were considered with low (20%) and high (75%) pretest probability of small-bowel Crohn's disease. Effectiveness was measured in quality-adjusted life-years (QALYs) gained. Parameter assumptions were tested with sensitivity analyses. With a moderate to high pretest probability of small-bowel Crohn's disease, and a higher likelihood of isolated jejunal disease, follow-up evaluation with CTE has an incremental cost-effectiveness ratio of less than $54,000/QALY-gained compared with SBFT. The addition of capsule endoscopy after ileocolonoscopy and negative CTE or SBFT costs greater than $500,000 per QALY-gained in all scenarios. Results were not sensitive to costs of tests or complications but were sensitive to test accuracies. The cost effectiveness of strategies depends critically on the pretest probability of Crohn's disease and if the terminal ileum is examined at ileocolonoscopy. CTE is a cost-effective alternative to SBFT in patients with moderate to high suspicion of small-bowel Crohn's disease. The addition of capsule endoscopy as a third test is not a cost-effective third test, even in patients with high pretest probability of disease. Copyright 2010 AGA Institute. Published by Elsevier Inc. All rights reserved.
Monsanto, Pedro; Almeida, Nuno; Lérias, Clotilde; Figueiredo, Pedro; Gouveia, Hermano; Sofia, Carlos
2012-04-01
in 21st century, endoscopic study of the small intestine has undergone a revolution with capsule endoscopy and balloon-assisted enteroscopy. The difficulties and morbidity associated with intraoperative enteroscopy, the gold-standard in the 20th century, made this technique to be relegated to a second level. evaluate the actual role and assess the diagnostic and therapeutic value of intraoperative enteroscopy in patients with obscure gastrointestinal bleeding. we conducted a retrospective study of 19 patients (11 males; mean age: 66.5 ± 15.3 years) submitted to 21 IOE procedures for obscure GI bleeding. Capsule endoscopy and double balloon enteroscopy had been performed in 10 and 5 patients, respectively. with intraoperative enteroscopy a small bowel bleeding lesion was identified in 79% of patients and a gastrointestinal bleeding lesion in 94%. Small bowel findings included: angiodysplasia (n = 6), ulcers (n = 4), small bowel Dieulafoy´s lesion (n = 2), bleeding from anastomotic vessels (n = 1), multiple cavernous hemangiomas (n = 1) and bleeding ectopic jejunal varices (n = 1). Agreement between capsule endoscopy and intraoperative enteroscopy was 70%. Endoscopic and/or surgical treatment was used in 77.8% of the patients with a positive finding on intraoperative enteroscopy, with a rebleeding rate of 21.4% in a mean 21-month follow-up period. Procedure-related mortality and postoperative complications have been 5 and 21%, respectively. intraoperative enteroscopy remains a valuable tool in selected patients with obscure GI bleeding, achieving a high diagnostic yield and allowing an endoscopic and/or surgical treatment in most of them. However, as an invasive procedure with relevant mortality and morbidity, a precise indication for its use is indispensable.
Gastrointestinal endoscopy in pregnancy
Savas, Nurten
2014-01-01
Gastrointestinal endoscopy has a major diagnostic and therapeutic role in most gastrointestinal disorders; however, limited information is available about clinical efficacy and safety in pregnant patients. The major risks of endoscopy during pregnancy include potential harm to the fetus because of hypoxia, premature labor, trauma and teratogenesis. In some cases, endoscopic procedures may be postponed until after delivery. When emergency or urgent indications are present, endoscopic procedures may be considered with some precautions. United States Food and Drug Administration category B drugs may be used in low doses. Endoscopic procedures during pregnancy may include upper gastrointestinal endoscopy, percutaneous endoscopic gastrostomy, sigmoidoscopy, colonoscopy, enteroscopy of the small bowel or video capsule endoscopy, endoscopic retrograde cholangiopancreatography and endoscopic ultrasonography. All gastrointestinal endoscopic procedures in pregnant patients should be performed in hospitals by expert endoscopists and an obstetrician should be informed about all endoscopic procedures. The endoscopy and flexible sigmoidoscopy may be safe for the fetus and pregnant patient, and may be performed during pregnancy when strong indications are present. Colonoscopy for pregnant patients may be considered for strong indications during the second trimester. Although therapeutic endoscopic retrograde cholangiopancreatography may be considered during pregnancy, this procedure should be performed only for strong indications and attempts should be made to minimize radiation exposure. PMID:25386072
Shrestha, Ravi; Mohammed, Shahed K; Hasan, Md Mehedi; Zhang, Xuechao; Wahid, Khan A
2016-08-01
Wireless capsule endoscopy (WCE) plays an important role in the diagnosis of gastrointestinal (GI) diseases by capturing images of human small intestine. Accurate diagnosis of endoscopic images depends heavily on the quality of captured images. Along with image and frame rate, brightness of the image is an important parameter that influences the image quality which leads to the design of an efficient illumination system. Such design involves the choice and placement of proper light source and its ability to illuminate GI surface with proper brightness. Light emitting diodes (LEDs) are normally used as sources where modulated pulses are used to control LED's brightness. In practice, instances like under- and over-illumination are very common in WCE, where the former provides dark images and the later provides bright images with high power consumption. In this paper, we propose a low-power and efficient illumination system that is based on an automated brightness algorithm. The scheme is adaptive in nature, i.e., the brightness level is controlled automatically in real-time while the images are being captured. The captured images are segmented into four equal regions and the brightness level of each region is calculated. Then an adaptive sigmoid function is used to find the optimized brightness level and accordingly a new value of duty cycle of the modulated pulse is generated to capture future images. The algorithm is fully implemented in a capsule prototype and tested with endoscopic images. Commercial capsules like Pillcam and Mirocam were also used in the experiment. The results show that the proposed algorithm works well in controlling the brightness level accordingly to the environmental condition, and as a result, good quality images are captured with an average of 40% brightness level that saves power consumption of the capsule.
New optical method for enhanced detection of colon cancer by capsule endoscopy
NASA Astrophysics Data System (ADS)
Ankri
2013-09-01
PillCam®COLON capsule endoscopy (CE), a non-invasive diagnostic tool of the digestive tract, has dramatically changed the diagnostic approach and has become an attractive alternative to the conventional colonoscopy for early detection of colorectal cancer. However, despite the significant progress and non-invasive detection capability, studies have shown that its sensitivity and specificity is lower than that of conventional colonoscopy. This work presents a new optical detection method, specifically tailored to colon cancer detection and based on the well-known optical properties of immune-conjugated gold nanorods (GNRs). We show, on a colon cancer model implanted in a chick chorioallantoic membrane (CAM), that this detection method enables conclusive differentiation between cancerous and normal tissues, where neither the distance between the light source and the intestinal wall, nor the background signal, affects the monitored signal. This optical method, which can easily be integrated in CE, is expected to reduce false positive and false negative results and improve identification of tumors and micro metastases.
OMOM capsule endoscopy in diagnosis of small bowel disease
Li, Chen-yi; Zhang, Bing-ling; Chen, Chun-xiao; Li, You-ming
2008-01-01
Objective: To assess the diagnostic efficiency of OMOM capsule endoscopy (CE) in a group of patients with different indications. Methods: Data from 89 consecutive patients (49 males, 40 females) with suspected small bowel disease who underwent OMOM CE (Jinshan Science and Technology Company, Chongqing, China) examination were obtained by retrospective review. The patients’ indications of the disease consisted of the following: obscure gastrointestinal bleeding (OGIB), abdominal pain or diarrhea, partial intestinal obstruction, suspected inflammatory bowel disease, tumor of unknown origin, hypoproteinemia, constipation, weight loss, and elevated tumor markers. Results: CE failed in one patient. Visualization of the entire small bowel was achieved in 75.0%. Capsules were naturally excreted by all patients. The detection rate of abnormalities was 70.5% for patients with suspected small bowel disease, and the diagnostic yield for patients with OGIB was higher than that for patients with abdominal pain or diarrhea (85.7% vs 53.3%, P<0.005). Angiodysplasia was the most common small bowel finding. Active bleeding sites were noted in the small intestine in 11 cases. Conclusion: OMOM CE is a useful diagnostic tool for the diagnosis of variably suspected small bowel disease, whose diagnostic efficiency is similar to that of the Pillcam SB (small bowel) CE (Given Imaging, Yoqneam, Israel). PMID:18988304
Khan, Tareq; Shrestha, Ravi; Imtiaz, Md. Shamin
2015-01-01
Presented is a new power-efficient colour generation algorithm for wireless capsule endoscopy (WCE) application. In WCE, transmitting colour image data from the human intestine through radio frequency (RF) consumes a huge amount of power. The conventional way is to transmit all R, G and B components of all frames. Using the proposed dictionary-based colour generation scheme, instead of sending all R, G and B frames, first one colour frame is sent followed by a series of grey-scale frames. At the receiver end, the colour information is extracted from the colour frame and then added to colourise the grey-scale frames. After a certain number of grey-scale frames, another colour frame is sent followed by the same number of grey-scale frames. This process is repeated until the end of the video sequence to maintain the colour similarity. As a result, over 50% of RF transmission power can be saved using the proposed scheme, which will eventually lead to a battery life extension of the capsule by 4–7 h. The reproduced colour images have been evaluated both statistically and subjectively by professional gastroenterologists. The algorithm is finally implemented using a WCE prototype and the performance is validated using an ex-vivo trial. PMID:26609405
A case of small bowel ulcer caused by NSAIDs and detected after capsule endoscope retention.
Sakuma, Toshiyuki; Gocho, Seiho; Ogasawara, Fusao; Tsukune, Yoko; Sawamoto, Kana; Numata, Makoto; Nagata, Naruhiko; Deguchi, Ryuzo; Mine, Tetsuya
2012-04-20
We recently detected an annular ulcer thought to have been caused by non-steroidal anti-inflammatory drugs (NSAIDs) when we performed small bowel capsule endoscopy on a patient with suspected small-bowel bleeding and a history of frequent use of oral NSAIDs. The patient was a 64-year-old woman who complained of bloody stools and abdominal pain. The annular ulcer showed concentric stenosis, which caused retention of the capsule endoscope. NSAIDs are some of the most frequently used anti-inflammatory analgesics, and even more frequent use can be expected with the aging of society. No reports to date appear to have described retention of a capsule endoscope due to annular ulceration caused by NSAIDs. We report herein our experience with a patient showing small-bowel ulcer caused by NSAIDs.
Computer-aided decision support systems for endoscopy in the gastrointestinal tract: a review.
Liedlgruber, Michael; Uhl, Andreas
2011-01-01
Today, medical endoscopy is a widely used procedure to inspect the inner cavities of the human body. The advent of endoscopic imaging techniques-allowing the acquisition of images or videos-created the possibility for the development of the whole new branch of computer-aided decision support systems. Such systems aim at helping physicians to identify possibly malignant abnormalities more accurately. At the beginning of this paper, we give a brief introduction to the history of endoscopy, followed by introducing the main types of endoscopes which emerged so far (flexible endoscope, wireless capsule endoscope, and confocal laser endomicroscope). We then give a brief introduction to computer-aided decision support systems specifically targeted at endoscopy in the gastrointestinal tract. Then we present general facts and figures concerning computer-aided decision support systems and summarize work specifically targeted at computer-aided decision support in the gastrointestinal tract. This summary is followed by a discussion of some common issues concerning the approaches reviewed and suggestions of possible ways to resolve them.
Ladas, S D; Triantafyllou, K; Spada, C; Riccioni, M E; Rey, J-F; Niv, Y; Delvaux, M; de Franchis, R; Costamagna, G
2010-03-01
These recommendations on video capsule endoscopy, an emerging technology with an impact on the practice of endoscopy, were developed by the European Society of Gastrointestinal Endoscopy (ESGE) Guidelines Committee. The first draft of each section was prepared by one or two members of the writing team, who were selected as experts on the content of that section on the basis of their published work. They used evidence-based methodology, performing MEDLINE and PubMed literature searches to identify relevant clinical studies. Abstracts from scientific meetings were included only if there was no published full paper on a particular topic. If there was disagreement, the first author of the Guideline made the final decision. Recommendations were graded according to the strength of the supporting evidence. The draft guideline was critically reviewed by all authors and submitted to the ESGE councillors for their critical review before approval of the final document. The ESGE Guidelines Committee acknowledges that this document is based on a critical review of the data available at the time of preparation and that further studies may be needed to clarify some aspects. Moreover, this Guideline may be revised as necessary to account for changes in technology, new data, or other aspects of clinical practice. This document should be regarded as supplying recommendations only to gastroenterologists in providing care to their patients. It is not a set of rules and should not be construed as establishing a legal standard of care, or as encouraging, advocating, requiring, or discouraging any particular treatment. These recommendations must be interpreted according to the clinician's knowledge, expertise, and clinical judgment in the management of individual patients and, if necessary, a course of action that varies from recommendations must be undertaken. Georg Thieme Verlag KG Stuttgart. New York.
Schiele, Julia T; Penner, Heike; Schneider, Hendrik; Quinzler, Renate; Reich, Gabriele; Wezler, Nikolai; Micol, William; Oster, Peter; Haefeli, Walter E
2015-10-01
We evaluated the prevalence of difficulties swallowing solid dosage forms in patients with stroke-induced dysphagia and whether swallowing tablets/capsules increases their risk of penetration and aspiration. Concurrently, we explored whether routinely performed assessment tests help identify patients at risk. Using video endoscopy, we evaluated how 52 patients swallowed four different placebos (round, oval, and oblong tablets and a capsule) with texture-modified water (TMW, pudding consistency) and milk and rated their swallowing performance according to the Penetration Aspiration Scale (PAS). Additionally, Daniels Test, Bogenhausener Dysphagiescore, Scandinavian Stroke Scale, Barthel Index, and Tinetti's Mobility Test were conducted. A substantial proportion of the patients experienced severe difficulties swallowing solid oral dosage forms (TMW: 40.4 %, milk: 43.5 %). Compared to the administration of TMW/milk alone, the placebos increased the PAS values in the majority of the patients (TMW: median PAS from 1.5 to 2.0; milk: median PAS from 1.5 to 2.5, each p value <0.0001) and residue values were significantly higher (p < 0.05). Whereas video-endoscopic examination reliably identified patients with difficulties swallowing medication, neither patients' self-evaluation nor one of the routinely performed bedside tests did. Therefore, before video-endoscopic evaluation, many drugs were modified unnecessarily and 20.8 % of these were crushed inadequately, although switching to another dosage form or drug would have been possible. Hence, safety and effectiveness of swallowing tablets and capsules should be evaluated routinely in video-endoscopic examinations, tablets/capsules should rather be provided with TMW than with milk, and the appropriateness of "non per os except medication" orders for dysphagic stroke patients should be questioned.
Video-based measurements for wireless capsule endoscope tracking
NASA Astrophysics Data System (ADS)
Spyrou, Evaggelos; Iakovidis, Dimitris K.
2014-01-01
The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions.
How much helpful is the capsule endoscopy for the diagnosis of small bowel lesions?
Ersoy, Osman; Sivri, Bulent; Arslan, Serap; Batman, Figen; Bayraktar, Yusuf
2006-01-01
AIM: To assess the practically usefulness and diagnostic yield of this new method in a group of patients with suspected small bowel lesions. METHODS: Capsule endoscopic (CE) examination by using M2A capsule endoscope TM (Given Imaging, Yoqneam, Israel) was performed in thirty nine patients (26 males, 13 females) with suspected small intestinal lesions. The composing of the patients was as follows: obscure gastrointestinal bleeding in twenty three patients, known Crohn’s disease in 6 patients, in whom CE was used to evaluate the severity and extension of the diseases, chronic diarrhea in 8 patients, abdominal pain in one patient and malignancy in one patient with unknown origin. RESULTS: In two patients CE failed. Different abnormalities were revealed in 26 patients overall. Detection rate of abnormalities was highest among patients with obscure gastrointestinal bleeding and the source of bleeding was demonstrated in 17 of 23 patients with obscure bleeding (73.9%). Entero-Behcet was diagnosed in two patients by CE as a source of obscure gastrointestinal bleeding. In 6 patients with known Crohn's disease, CE revealed better evaluation of the disease extension. In 3 of 8 (37.5%) patients with chronic diarrhea; CE revealed some mucosal abnormalities as the cause of chronic diarrhea. In a patient with unexplained abdominal pain and in a cancer patient with unknown origin, CE examination was normal. CONCLUSION: In our relatively small series, we found that capsule endoscopy is a useful diagnostic tool particularly in diagnosis of obscure gastrointestinal bleeding, chronic diarrhea and in estimating the extension of Crohn’s disease. PMID:16804980
Wireless power and data transmission strategies for next-generation capsule endoscopes
NASA Astrophysics Data System (ADS)
Puers, R.; Carta, R.; Thoné, J.
2011-05-01
Capsular endoscopy is becoming increasingly popular as an alternative to traditional gastro-intestinal (GI) examination techniques. However, the breakthrough of these devices is hindered by the limited amount of power that can be stored in a tiny pill. Most commercial devices use two watch batteries that can only provide an average power of 25 mW for about 6 h, certainly not sufficient for advanced robotic features. A dedicated inductive powering system, operating at 1 MHz to limit the human body absorption, has been developed which was proven to support the transfer of over 300 mW. The system relies on a condensed set of orthogonal ferrite coils, embedded in the capsule, and an external unit based on a Helmholtz coil driven by a class E amplifier. Control data can be sent through the inductive link by modulating the power carrier, whereas a dedicated high data rate RF link is used to transfer the images from the capsule to the base station. Besides evaluating the compatibility with radio transmission, several demonstrators were assembled combining the wireless powering system with various locomotion strategies and LED illumination. This paper describes the design and implementation of the inductive powering system, its combination with data transmission techniques and the testing activity with other capsule-dedicated modules.
Diagnostic yield of capsule endoscopy in refractory celiac disease.
Barret, Maximilien; Malamut, Georgia; Rahmi, Gabriel; Samaha, Elia; Edery, Joël; Verkarre, Virginie; Macintyre, Elizabeth; Lenain, Emilie; Chatellier, Gilles; Cerf-Bensussan, Nadine; Cellier, Christophe
2012-10-01
Capsule endoscopy (CE) allows for the assessment of the small bowel in numerous intestinal diseases, including celiac disease (CD). The main advantage of CE is the complete visualization of the intestinal mucosal surface. The objective of this study was to investigate whether CE can predict the severity of CD and detect complications. We retrospectively studied the medical files of 9 patients with symptomatic CD, 11 patients with refractory celiac disease type I (RCDI) and 18 patients with refractory celiac disease type II (RCDII), and 45 patients without CD who were investigated both CE and upper endoscopy or enteroscopy. The type of CD was diagnosed on the basis of a centralized histological review, flow cytometry analysis of intraepithelial lymphocytes, and the analysis of T-cell receptor rearrangement by multiplex polymerase chain reaction. A total of 47 CEs (10, 11, and 26 CEs in the symptomatic CD, RCDI, and RCDII groups, respectively) from the 38 celiac patients and 47 CEs from the 45 nonceliac patients were retrospectively reviewed. Villous atrophy, numerous, or distally located ulcers were more frequent in celiac patients than in controls. Among celiac patients, CE was of acceptable quality in 96% of cases and was complete in 62% of cases. The concordance of CE with histology for villous atrophy was better than that of optic endoscopy (κ coefficient =0.45 vs. 0.24, P<0.001). Extensive mucosal damage on CE was associated with low serum albumin (P=0.003) and the RCDII form (P=0.02). Three cases of overt lymphoma were detected by CE during the follow-up. CE findings have a satisfactory concordance with histology and nutritional status in patients with symptomatic or refractory CD. Moreover, CE may predict the type of RCD and allows for the early detection of overt lymphoma.
Shibuya, Tomoyoshi; Mori, Hiroki; Takeda, Tsutomu; Konishi, Masae; Fukuo, Yuka; Matsumoto, Kenshi; Beppu, Kazuko; Sakamoto, Naoto; Osada, Taro; Nagahara, Akihito; Otaka, Michiro; Ogihara, Tatsuo; Watanabe, Sumio
2012-01-01
Capsule endoscopy (CE) allows direct examination of the small bowel in a safe, noninvasive and well-tolerated manner. Nonetheless, experience indicates failure to reach the cecum in 20-30% of patients within the 8 hour battery life. Attempts to improve the completion rate (CR) as defined by reaching the cecum have been unsuccessful. This study was to investigate the relationship between patients' physical activity and CR. Between January 2009 and January 2010, 76 patients (44 men, 32 women; median age 64.5 yr) underwent CE for the diagnosis of small intestinal disorders. Indications for CE were obscure gastrointestinal bleeding/anemia (62 cases), others (14 cases). Patients were divided into an outpatient group (n=23), mild bed rest group (n=35) and strict bed rest group (n=18). For all patients, the average gastric transit time was 65.5 minutes, small bowel transit time was 301.4 minutes and the CR was 86.8%. However, the CR was 100% (23/23) in the outpatient group, an 85.7% (30/35) in the mild bed rest group, and 72.2% (13/18) in the strict bed rest group. The CR increased with physical activity of patients by Cochran-Armitage Trend Test (p=0.009). In multivariate logistic regression analyses, low physical activity was a significant risk factor for failure to reach the cecum during CE examination; adjusted OR: 3.39, 95% CI: 1.01-11.42 (p=0.048). Our observations suggested that increasing physical activity would increase the likelihood of a complete bowel examination by CE. Further, for CE, inconvenient bowel preparations like the use of polyethylene glycol may be avoided.
Hashimoto, Shinichi; Ogihara, Hiroyuki; Suenaga, Masato; Fujita, Yusuke; Terai, Shuji; Hamamoto, Yoshihiko; Sakaida, Isao
2017-08-01
Visibility in capsule endoscopic images is presently evaluated through intermittent analysis of frames selected by a physician. It is thus subjective and not quantitative. A method to automatically quantify the visibility on capsule endoscopic images has not been reported. Generally, when designing automated image recognition programs, physicians must provide a training image; this process is called supervised learning. We aimed to develop a novel automated self-learning quantification system to identify visible areas on capsule endoscopic images. The technique was developed using 200 capsule endoscopic images retrospectively selected from each of three patients. The rate of detection of visible areas on capsule endoscopic images between a supervised learning program, using training images labeled by a physician, and our novel automated self-learning program, using unlabeled training images without intervention by a physician, was compared. The rate of detection of visible areas was equivalent for the supervised learning program and for our automatic self-learning program. The visible areas automatically identified by self-learning program correlated to the areas identified by an experienced physician. We developed a novel self-learning automated program to identify visible areas in capsule endoscopic images.
Abnormal Image Detection in Endoscopy Videos Using a Filter Bank and Local Binary Patterns
Nawarathna, Ruwan; Oh, JungHwan; Muthukudage, Jayantha; Tavanapong, Wallapak; Wong, Johnny; de Groen, Piet C.; Tang, Shou Jiang
2014-01-01
Finding mucosal abnormalities (e.g., erythema, blood, ulcer, erosion, and polyp) is one of the most essential tasks during endoscopy video review. Since these abnormalities typically appear in a small number of frames (around 5% of the total frame number), automated detection of frames with an abnormality can save physician’s time significantly. In this paper, we propose a new multi-texture analysis method that effectively discerns images showing mucosal abnormalities from the ones without any abnormality since most abnormalities in endoscopy images have textures that are clearly distinguishable from normal textures using an advanced image texture analysis method. The method uses a “texton histogram” of an image block as features. The histogram captures the distribution of different “textons” representing various textures in an endoscopy image. The textons are representative response vectors of an application of a combination of Leung and Malik (LM) filter bank (i.e., a set of image filters) and a set of Local Binary Patterns on the image. Our experimental results indicate that the proposed method achieves 92% recall and 91.8% specificity on wireless capsule endoscopy (WCE) images and 91% recall and 90.8% specificity on colonoscopy images. PMID:25132723
A video wireless capsule endoscopy system powered wirelessly: design, analysis and experiment
NASA Astrophysics Data System (ADS)
Pan, Guobing; Xin, Wenhui; Yan, Guozheng; Chen, Jiaoliao
2011-06-01
Wireless capsule endoscopy (WCE), as a relatively new technology, has brought about a revolution in the diagnosis of gastrointestinal (GI) tract diseases. However, the existing WCE systems are not widely applied in clinic because of the low frame rate and low image resolution. A video WCE system based on a wireless power supply is developed in this paper. This WCE system consists of a video capsule endoscope (CE), a wireless power transmission device, a receiving box and an image processing station. Powered wirelessly, the video CE has the abilities of imaging the GI tract and transmitting the images wirelessly at a frame rate of 30 frames per second (f/s). A mathematical prototype was built to analyze the power transmission system, and some experiments were performed to test the capability of energy transferring. The results showed that the wireless electric power supply system had the ability to transfer more than 136 mW power, which was enough for the working of a video CE. In in vitro experiments, the video CE produced clear images of the small intestine of a pig with the resolution of 320 × 240, and transmitted NTSC format video outside the body. Because of the wireless power supply, the video WCE system with high frame rate and high resolution becomes feasible, and provides a novel solution for the diagnosis of the GI tract in clinic.
Semantic and topological classification of images in magnetically guided capsule endoscopy
NASA Astrophysics Data System (ADS)
Mewes, P. W.; Rennert, P.; Juloski, A. L.; Lalande, A.; Angelopoulou, E.; Kuth, R.; Hornegger, J.
2012-03-01
Magnetically-guided capsule endoscopy (MGCE) is a nascent technology with the goal to allow the steering of a capsule endoscope inside a water filled stomach through an external magnetic field. We developed a classification cascade for MGCE images with groups images in semantic and topological categories. Results can be used in a post-procedure review or as a starting point for algorithms classifying pathologies. The first semantic classification step discards over-/under-exposed images as well as images with a large amount of debris. The second topological classification step groups images with respect to their position in the upper gastrointestinal tract (mouth, esophagus, stomach, duodenum). In the third stage two parallel classifications steps distinguish topologically different regions inside the stomach (cardia, fundus, pylorus, antrum, peristaltic view). For image classification, global image features and local texture features were applied and their performance was evaluated. We show that the third classification step can be improved by a bubble and debris segmentation because it limits feature extraction to discriminative areas only. We also investigated the impact of segmenting intestinal folds on the identification of different semantic camera positions. The results of classifications with a support-vector-machine show the significance of color histogram features for the classification of corrupted images (97%). Features extracted from intestinal fold segmentation lead only to a minor improvement (3%) in discriminating different camera positions.
Magnetically Actuated Soft Capsule With the Multimodal Drug Release Function
Yim, Sehyuk; Goyal, Kartik; Sitti, Metin
2014-01-01
In this paper, we present a magnetically actuated multimodal drug release mechanism using a tetherless soft capsule endoscope for the treatment of gastric disease. Because the designed capsule has a drug chamber between both magnetic heads, if it is compressed by the external magnetic field, the capsule could release a drug in a specific position locally. The capsule is designed to release a drug in two modes according to the situation. In the first mode, a small amount of drug is continuously released by a series of pulse type magnetic field (0.01–0.03 T). The experimental results show that the drug release can be controlled by the frequency of the external magnetic pulse. In the second mode, about 800 mm3 of drug is released by the external magnetic field of 0.07 T, which induces a stronger magnetic attraction than the critical force for capsule’s collapsing. As a result, a polymeric coating is formed around the capsule. The coated area is dependent on the drug viscosity. This paper presents simulations and various experiments to evaluate the magnetically actuated multimodal drug release capability. The proposed soft capsules could be used as minimally invasive tetherless medical devices with therapeutic capability for the next generation capsule endoscopy. PMID:25378896
Detection of protruding lesion in wireless capsule endoscopy videos of small intestine
NASA Astrophysics Data System (ADS)
Wang, Chengliang; Luo, Zhuo; Liu, Xiaoqi; Bai, Jianying; Liao, Guobin
2018-02-01
Wireless capsule endoscopy (WCE) is a developed revolutionary technology with important clinical benefits. But the huge image data brings a heavy burden to the doctors for locating and diagnosing the lesion images. In this paper, a novel and efficient approach is proposed to help clinicians to detect protruding lesion images in small intestine. First, since there are many possible disturbances such as air bubbles and so on in WCE video frames, which add the difficulty of efficient feature extraction, the color-saliency region detection (CSD) method is developed for extracting the potentially saliency region of interest (SROI). Second, a novel color channels modelling of local binary pattern operator (CCLBP) is proposed to describe WCE images, which combines grayscale and color angle. The CCLBP feature is more robust to variation of illumination and more discriminative for classification. Moreover, support vector machine (SVM) classifier with CCLBP feature is utilized to detect protruding lesion images. Experimental results on real WCE images demonstrate that proposed method has higher accuracy on protruding lesion detection than some art-of-state methods.
Overview of robotic colorectal surgery: Current and future practical developments
Roy, Sudipta; Evans, Charles
2016-01-01
Minimal access surgery has revolutionised colorectal surgery by offering reduced morbidity and mortality over open surgery, while maintaining oncological and functional outcomes with the disadvantage of additional practical challenges. Robotic surgery aids the surgeon in overcoming these challenges. Uptake of robotic assistance has been relatively slow, mainly because of the high initial and ongoing costs of equipment but also because of limited evidence of improved patient outcomes. Advances in robotic colorectal surgery will aim to widen the scope of minimal access surgery to allow larger and more complex surgery through smaller access and natural orifices and also to make the technology more economical, allowing wider dispersal and uptake of robotic technology. Advances in robotic endoscopy will yield self-advancing endoscopes and a widening role for capsule endoscopy including the development of motile and steerable capsules able to deliver localised drug therapy and insufflation as well as being recharged from an extracorporeal power source to allow great longevity. Ultimately robotic technology may advance to the point where many conventional surgical interventions are no longer required. With respect to nanotechnology, surgery may eventually become obsolete. PMID:26981188
Blood detection in wireless capsule endoscope images based on salient superpixels.
Iakovidis, Dimitris K; Chatzis, Dimitris; Chrysanthopoulos, Panos; Koulaouzidis, Anastasios
2015-08-01
Wireless capsule endoscopy (WCE) enables screening of the gastrointestinal (GI) tract with a miniature, optical endoscope packed within a small swallowable capsule, wirelessly transmitting color images. In this paper we propose a novel method for automatic blood detection in contemporary WCE images. Blood is an alarming indication for the presence of pathologies requiring further treatment. The proposed method is based on a new definition of superpixel saliency. The saliency of superpixels is assessed upon their color, enabling the identification of image regions that are likely to contain blood. The blood patterns are recognized by their color features using a supervised learning machine. Experiments performed on a public dataset using automatically selected first-order statistical features from various color components indicate that the proposed method outperforms state-of-the-art methods.
Niv, Y; Ilani, S; Levi, Z; Hershkowitz, M; Niv, E; Fireman, Z; O'Donnel, S; O'Morain, C; Eliakim, R; Scapa, E; Kalantzis, N; Kalantzis, C; Apostolopoulos, P; Gal, E
2012-01-01
The Capsule Endoscopy Crohn's Disease Activity Index (CECDAI or Niv score) was devised to measure mucosal disease activity using video capsule endoscopy (VCE). The aim of the current study was to prospectively validate the use of the scoring system in daily practice. This was a multicenter, double-blind, prospective, controlled study of VCE videos from 62 consecutive patients with isolated small-bowel Crohn's disease. The CECDAI was designed to evaluate three main parameters of Crohn's disease: inflammation (A), extent of disease (B), and stricture (C), in both the proximal and distal segments of the small bowel. The final score was calculated by adding the two segmental scores: CECDAI = ([A1 × B1] + C1) + ([A2 × B2] + C2). Each examiner in every site interpreted 6 - 10 videos and calculated the CECDAI. The de-identified CD-ROMs were then coded and sent to the principal investigator for CECDAI calculation. The cecum was reached in 72 % and 86 % of examinations, and proximal small-bowel involvement was found in 56 % and 62 % of the patients, according to the site investigators and principal investigator, respectively. Significant correlation was demonstrated between the calculation of the CECDAI by the individual site investigators and that performed by the principal investigator. Overall correlation between endoscopists from the different study centers was good, with r = 0.767 (range 0.717 - 0.985; Kappa 0.66; P < 0.001). There was no correlation between the CECDAI and the Crohn's Disease Activity Index or the Inflammatory Bowel Disease Quality of Life Questionnaire or any of their components. A new scoring system of mucosal injury in Crohn's disease of the small intestine, the CECDAI, was validated. Its use in controlled trials and/or regular follow-up of these patients is advocated. © Georg Thieme Verlag KG Stuttgart · New York.
Postgate, Aymer; Tekkis, Paris; Patterson, Neil; Fitzpatrick, Aine; Bassett, Paul; Fraser, Chris
2009-05-01
Capsule endoscopy (CE) is limited by incomplete small-bowel transit and poor view quality in the distal bowel. Currently, there is no consensus regarding the use of bowel purgatives or prokinetics in CE. To evaluate the usefulness of bowel purgatives and prokinetics in small-bowel CE. Prospective single-blind randomized controlled study. Academic endoscopy unit. A total of 150 patients prospectively recruited. Patients were randomized to 1 of 4 preparations: "standard" (fluid restriction then nothing by mouth 12 hours before the procedure, water and simethicone at capsule ingestion [S]); "standard" + 10 mg oral metoclopramide before the procedure (M); Citramag + senna bowel-purgative regimen the evening before CE (CS); Citramag + senna + 10 mg metoclopramide before the procedure (CSM). Gastric transit time (GTT) and small-bowel transit time (SBTT), completion rates (CR), view quality, and patient acceptability. positive findings, diagnostic yield. No significant difference was noted among groups for GTT (median [minutes] M, CS, and CSM vs S: 17.3, 24.7, and 15.1 minutes vs 16.8 minutes, respectively; P = .62, .18, and .30, respectively), SBTT (median [minutes] M, CS, and CSM vs S: 260, 241, and 201 vs 278, respectively; P = .91, .81, and .32, respectively), or CRs (85%, 85%, and 88% vs 89% for M, CS, and CSM vs S, respectively; P = .74, .74, and 1.00, respectively). There was no significant difference in view quality among groups (of 44: 38, 37, and 40 vs 37 for M, CS, and CSM, vs S, respectively; P = .18, .62, and .12, respectively). Diagnostic yield was similar among the groups. CS and CSM regimens were significantly less convenient (P < .001), and CS was significantly less comfortable (P = .001) than standard preparation. Bowel purgatives and prokinetics do not improve CRs or view quality at CE, and bowel purgatives reduce patient acceptability.
Muhammad, Khan; Sajjad, Muhammad; Baik, Sung Wook
2016-05-01
In this paper, the problem of secure transmission of sensitive contents over the public network Internet is addressed by proposing a novel data hiding method in encrypted images with dual-level security. The secret information is divided into three blocks using a specific pattern, followed by an encryption mechanism based on the three-level encryption algorithm (TLEA). The input image is scrambled using a secret key, and the encrypted sub-message blocks are then embedded in the scrambled image by cyclic18 least significant bit (LSB) substitution method, utilizing LSBs and intermediate LSB planes. Furthermore, the cover image and its planes are rotated at different angles using a secret key prior to embedding, deceiving the attacker during data extraction. The usage of message blocks division, TLEA, image scrambling, and the cyclic18 LSB method results in an advanced security system, maintaining the visual transparency of resultant images and increasing the security of embedded data. In addition, employing various secret keys for image scrambling, data encryption, and data hiding using the cyclic18 LSB method makes the data recovery comparatively more challenging for attackers. Experimental results not only validate the effectiveness of the proposed framework in terms of visual quality and security compared to other state-of-the-art methods, but also suggest its feasibility for secure transmission of diagnostically important keyframes to healthcare centers and gastroenterologists during wireless capsule endoscopy.
Endoscopic training in gastroenterology fellowship: adherence to core curriculum guidelines.
Jirapinyo, Pichamol; Imaeda, Avlin B; Thompson, Christopher C
2015-12-01
The Gastroenterology Core Curriculum and American Society of Gastrointestinal Endoscopy provide guidelines for endoscopic training. Program adherence to these recommendations is unclear. This study aims to assess endoscopic training experience during fellowship. Questionnaire study. The questionnaire was circulated to US fellowship programs, with the assistance of the American Gastroenterological Association. Graduating third-year fellows. Seventy-three fellows returned the questionnaire. Nearly all fellows met the required numbers for esophagoduodenoscopy (98%) and colonoscopy (100%), with fewer meeting requirements for PEG (73%) and non-variceal hemorrhage (75%). The majority of fellows did not meet minimum numbers for variceal banding (40%), esophageal dilation (43%), capsule endoscopy (42%). Fellows rated training in cognitive aspects of endoscopy as 3.86 [1 (inadequate), 5 (excellent)] and reported greatest emphasis on interpreting endoscopic findings and least on virtual colonography. Quality indicators of endoscopy received little emphasis (rating of 3.04; p = 0.00001), with adenoma detection rate being least emphasized. Fifty-six percent of fellows reported having routine endoscopy conferences. Half of the programs have endoscopic simulators, with 15% of fellows being required to use simulation. Following direct hands-on experience, fellows rated external endoscopy courses (64%) as the next most useful experience. Many fellows do not meet required numbers for several endoscopic procedures, and quality indicators receive little emphasis during training. Most programs do not provide simulation training or hold regular endoscopy conferences. Fellowship programs should perform internal audits and make feasible adjustments. Furthermore, it may be time for professional societies to revisit training guidelines.
Poon, Carmen C Y; Leung, Billy; Chan, Cecilia K W; Lau, James Y W; Chiu, Philip W Y
2016-02-01
The current design of capsule endoscope is limited by the inability to control the motion within gastrointestinal tract. The rising incidence of gastrointestinal cancers urged improvement in the method of screening endoscopy. This preclinical study aimed to design and develop a novel locomotive module for capsule endoscope. We investigated the feasibility and physical properties of this newly designed caterpillar-like capsule endoscope with a view to enhancing screening endoscopy. This study consisted of preclinical design and experimental testing on the feasibility of automated locomotion for a prototype caterpillar endoscope. The movement was examined first in the PVC tube and then in porcine intestine. The image captured was transmitted to handheld device to confirm the control of movement. The balloon pressure and volume as well as the contact force between the balloon and surroundings were measured when the balloon was inflated inside (1) a hard PVC tube, (2) a soft PVC tube, (3) muscular sites of porcine colons and (4) less muscular sites of porcine colons. The prototype caterpillar endoscope was able to move inward and backward within the PVC tubing and porcine intestine. Images were able to be captured from the capsule endoscope attached and being observed with a handheld device. Using the onset of a contact force as indication of the buildup of the gripping force between the balloon and the lumen walls, it is concluded from the results of this study that the rate of change in balloon pressure and volume is two good estimators to optimize the inflation of the balloon. The results of this study will facilitate further refinement in the design of caterpillar robotic endoscope to move inside the GI tract.
NASA Astrophysics Data System (ADS)
Do, Dukho; Kang, DongKyun; Tabatabaei, Nima; Grant, Catriona N.; Nishioka, Norman S.; Rosenberg, Mireille; Hesterberg, Paul E.; Yuan, Qian; Garber, John J.; Katz, Aubrey J.; Shreffler, Wayne G.; Tearney, Guillermo J.
2017-02-01
Eosinophilic Esophagitis (EoE) is an inflammatory disease caused by inhaled or ingested food allergies, and characterized by the infiltration of eosinophils in the esophagus. The gold standard for diagnosing EoE is to conduct endoscopy and obtain multiple biopsy specimens from different portions of the esophagus; an exam is considered positive if more than 15 eosinophils per high power field (HPF) in any of the biopsies. This method of diagnosis is problematic because endoscopic biopsy is expensive and poorly tolerated and the esophageal eosinophil burden needs to be monitored frequently during the course of the disease. Spectrally encoded confocal microscopy (SECM) is a high-speed confocal microscopy technology that can visualize individual eosinophils in large microscopic images of the human esophagus, equivalent to more than 30,000 HPF. Previously, we have demonstrated that tethered capsule SECM can be conducted in unsedated subjects with diagnosed EoE. However, speckle noise and the relatively low resolution in images obtained with the first capsule prototypes made it challenging to distinguish eosinophils from other cells. In this work, we present a next-generation tethered SECM capsule, which has been modified to significantly improve image quality. First, we substituted the single mode fiber with a dual-clad fiber to reduce speckle noise. A gradient-index multimode fiber was fusion spliced at the tip of the dual-clad fiber to increase the effective numerical aperture of the fiber from 0.09 to 0.15, expanding the beam more rapidly to increase the illumination aperture at the objective. These modifications enabled the new SECM capsule to achieve a lateral resolution of 1.8 µm and an axial resolution of 16.1 µm, which substantially improves the capacity of this probe to visualize cellular features in human tissue. The total size of the SECM capsule remained 6.75 mm in diameter and 31 mm in length. We are now in the process of testing this new SECM capsule in humans. Early results using this new SECM capsule suggest that this technology has the potential to be an effective tool for the diagnosis of EoE.
Triantafyllou, Konstantinos; Gkolfakis, Paraskevas; Viazis, Nikos; Tsibouris, Panagiotis; Tsigaridas, Athanasios; Apostolopoulos, Periklis; Anastasiou, John; Hounda, Eleni; Skianis, Ioannis; Katopodi, Konstantina; Ndini, Xhoela; Alexandrakis, George; Karamanolis, Demetrios G
2017-02-01
Since its introduction, small bowel video capsule endoscopy (VCE) use has evolved considerably. Evaluation of the temporal changes of small bowel VCE utilization in three tertiary centers in Greece in Era 1 (2002-2009) and Era 2 (2010-2014) and the development a forecast model for future VCE use during 2015-2017. Data from all small bowel VCE examinations were retrieved and analyzed in terms of the annual number of the performed examinations, their indications and the significance of their findings. Overall, we evaluated 3724 VCE examinations. The number of studies peaked in 2009 (n=595) and then decreased to reach 225 in 2014. Overall, more (53.8 vs. 51.4%) patients with iron-deficiency anemia and obscure gastrointestinal bleeding (IDA/OGIB) and fewer (10.7 vs. 14%) patients with chronic diarrhea were evaluated in Era 2 compared with Era 1 (P=0.046). In Era 2, there were more nondiagnostic examinations (39.5 vs. 29.3%, P<0.001), whereas the rate of cases with relevant findings decreased from 47.8 to 40.9%. According to the time trend analysis, we developed a forecast model with two scenarios: the pessimistic and the optimistic. Validation of the model with 2015 data showed that reality was close to the pessimistic scenario: the number of exams further decreased to 190, studies carried out for IDA/OGIB increased to 67%, and there were more negative than positive exams (40.7 vs. 39.2%). The number of VCE studies carried out after the emergence of the financial crisis decreased significantly and VCE indications were optimized. Our forecast model predicts lower numbers of VCE studies, with IDA/OGIB being the dominant indication. However, the predicted increase of negative exams requires further evaluation.
Bowel preparations for capsule endoscopy: a comparison between simethicone and magnesium citrate.
Esaki, Motohiro; Matsumoto, Takayuki; Kudo, Tetsuji; Yanaru-Fujisawa, Ritsuko; Nakamura, Shotaro; Iida, Mitsuo
2009-01-01
Bowel preparation for capsule endoscopy (CE) has not been standardized. This study aimed to compare CE images between patients prepared by simethicone and those prepared by magnesium citrate. Retrospective analysis of case series of our hospital from 2004 to 2007. Single center. CE images of 75 patients receiving bowel preparation either by 200 mg of simethicone (n=39) or by 34 g of magnesium citrate (n=36) were retrospectively investigated. Grades of fluid transparency and mucosal invisibility by air bubbles and food residue were compared between the 2 preparations. Capsule transit time, frequency of positive findings, and interobserver variations between 2 observers were also investigated. Image quality and diagnostic yield of CE. Fluid transparency in the first and the third time segments of the small intestine was better in patients prepared by magnesium citrate than in those prepared by simethicone (P= .001 and P= .03, respectively). On the other hand, mucosal invisibility was not different in any part of the small intestine between the 2 groups. Neither gastric transit time nor small-bowel transit time was different between the 2 groups. The diagnostic yield of CE correlated significantly with fluid transparency (P= .04), but it did not correlate with mucosal invisibility. Single-center retrospective study. Magnesium citrate seems to be a recommended preparation for CE compared with simethicone. The fluid transparency, rather than the mucosal invisibility, may be a factor associated with the diagnostic yield of CE.
Katzka, David A; Geno, Debra M; Ravi, Anupama; Smyrk, Thomas C; Lao-Sirieix, Pierre; Miremadi, Ahmed; Miramedi, Ahmed; Debiram, Irene; O'Donovan, Maria; Kita, Hirohito; Kephart, Gail M; Kryzer, Lori A; Camilleri, Michael; Alexander, Jeffrey A; Fitzgerald, Rebecca C
2015-01-01
Management of eosinophilic esophagitis (EoE) requires repeated endoscopic collection of mucosal samples to assess disease activity and response to therapy. An easier and less expensive means of monitoring of EoE is required. We compared the accuracy, safety, and tolerability of sample collection via Cytosponge (an ingestible gelatin capsule comprising compressed mesh attached to a string) with those of endoscopy for assessment of EoE. Esophageal tissues were collected from 20 patients with EoE (all with dysphagia, 15 with stricture, 13 with active EoE) via Cytosponge and then by endoscopy. Number of eosinophils/high-power field and levels of eosinophil-derived neurotoxin were determined; hematoxylin-eosin staining was performed. We compared the adequacy, diagnostic accuracy, safety, and patient preference for sample collection via Cytosponge vs endoscopy procedures. All 20 samples collected by Cytosponge were adequate for analysis. By using a cutoff value of 15 eosinophils/high power field, analysis of samples collected by Cytosponge identified 11 of the 13 individuals with active EoE (83%); additional features such as abscesses were also identified. Numbers of eosinophils in samples collected by Cytosponge correlated with those in samples collected by endoscopy (r = 0.50, P = .025). Analysis of tissues collected by Cytosponge identified 4 of the 7 patients without active EoE (57% specificity), as well as 3 cases of active EoE not identified by analysis of endoscopy samples. Including information on level of eosinophil-derived neurotoxin did not increase the accuracy of diagnosis. No complications occurred during the Cytosponge procedure, which was preferred by all patients, compared with endoscopy. In a feasibility study, the Cytosponge is a safe and well-tolerated method for collecting near mucosal specimens. Analysis of numbers of eosinophils/high-power field identified patients with active EoE with 83% sensitivity. Larger studies are needed to establish the efficacy and safety of this method of esophageal tissue collection. ClinicalTrials.gov number: NCT01585103. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.
Atay, Orhan; Mahajan, Lori; Kay, Marsha; Mohr, Franziska; Kaplan, Barbara; Wyllie, Robert
2009-08-01
Capsule retention is a potential complication of capsule endoscopy (CE). The aims of our study were to determine the incidence of capsule retention in pediatric patients undergoing CE and to identify potential risk factors for capsule retention. We performed an institutional review board-approved retrospective chart review of pediatric patients undergoing CE studies at a single center. Data collected included patient age, sex, prior diagnosis of inflammatory bowel disease (IBD), CE indication, prior small bowel series results, study result, and complications. Two hundred seven CE procedures were performed in pediatric patients during the study period. Capsule retention occurred in 3 (1.4%) of the 207 studies. All 3 patients had known Crohn disease (CD). The risk of capsule retention in pediatric patients with known IBD was 5.2% (3/58). The risk of capsule retention for patients with suspected IBD and all other indications was 0%. If small bowel disease was identified on upper gastrointestinal series in patients with known CD, then the risk of capsule retention was 37.5% (3/8). Only 7 patients with known IBD had a body mass index (BMI) below the 5th percentile. Of these 7 patients, 3 (43%) had capsule retention. Red flags for potential CE retention identified in our study include known IBD (5.2% retention risk), previous small bowel follow-through demonstrating small bowel CD (37.5% retention risk), and BMI <5th percentile with known IBD (43% retention risk). Caution is advised in these pediatric patients before capsule ingestion.
Development and Testing of a Magnetically Actuated Capsule Endoscopy for Obesity Treatment
Do, Thanh Nho; Seah, Tian En Timothy; Yu, Ho Khek; Phee, Soo Jay
2016-01-01
Intra-gastric balloons (IGB) have become an efficient and less invasive method for obesity treatment. The use of traditional IGBs require complex insertion tools and flexible endoscopes to place and remove the balloon inside the patient’s stomach, which may cause discomfort and complications to the patient. This paper introduces a new ingestible weight-loss capsule with a magnetically remote-controlled inflatable and deflatable balloon. To inflate the balloon, biocompatible effervescent chemicals are used. As the source of the actuation is provided via external magnetic fields, the magnetic capsule size can be significantly reduced compared to current weight-loss capsules in the literature. In addition, there are no limitations on the power supply. To lose weight, the obese subject needs only to swallow the magnetic capsule with a glass of water. Once the magnetic capsule has reached the patient’s stomach, the balloon will be wirelessly inflated to occupy gastric space and give the feeling of satiety. The balloon can be wirelessly deflated at any time to allow the magnetic capsule to travel down the intestine and exit the body via normal peristalsis. The optimal ratio between the acid and base to provide the desired gas volume is experimentally evaluated and presented. A prototype capsule (9.6mm x 27mm) is developed and experimentally validated in ex-vivo experiments. The unique ease of delivery and expulsion of the proposed magnetic capsule is slated to make this development a good treatment option for people seeking to lose excess weight. PMID:26815309
[Diagnostic yield of video capsule endoscopy in premenopausal women with iron-deficiency anemia].
Garrido Durán, Carmen; Iyo Miyashiro, Eduardo; Páez Cumpa, Claudia; Khorrami Minaei, Sam; Erimeiku Barahona, Alicia; Llompart Rigo, Alfredo
2015-01-01
Clinical practice guidelines recommend video capsule endoscopy (VCE) studies in patients with iron-deficiency anemia (IDA) after conventional upper and lower endoscopies but there is a need for studies demonstrating the diagnostic yield, clinical impact, and cost in some patient subgroups. 1.To determine the diagnostic yield of VCE in premenopausal women with IDA compared with that in men and postmenopausal women. 2. To identify the presence of VCE predictors in premenopausal women. 3. To estimate the cost-clinical impact relationship associated with VCE in this indication. We retrospectively analyzed 408 patients who underwent VCE. Patients with IDA were enrolled (premenopausal, postmenopausal women, and men), with previous normal work-up by conventional endoscopies. A total of 249 patients were enrolled: 131 women (52.6%), of which 51 were premenopausal and 80 were post-menopausal, and 118 men. The mean age was 60.7±16 years. The diagnostic yield of VCE for the diagnosis of IDA was 44.6% (95% CI 39.9 - 50.8). Diagnostic yield was 50.8% vs 38.9% in men vs women (p=0.05) and was 55% vs 13.7% in postmenopausal vs premenopausal women (p<0.001). No predictors of small bowel lesions were found in premenopausal women. The most common findings in the postmenopausal group were angioectasias (70.5%) and erosions (57.1%) in the premenopausal group. The cost in premenopausal women was 44.727€ and 86.3% of the procedures had no clinical impact. The diagnostic yield of VCE is low in the etiological study of IDA in premenopausal women and there is no cost-effectiveness in relation to clinical impact. No predictors of small bowel lesions were found in this group. Copyright © 2015 Elsevier España, S.L.U. and AEEH y AEG. All rights reserved.
Evaluation of small bowel blood flow in healthy subjects receiving low-dose aspirin
Nishida, Urara; Kato, Mototsugu; Nishida, Mutsumi; Kamada, Go; Yoshida, Takeshi; Ono, Shouko; Shimizu, Yuichi; Asaka, Masahiro
2011-01-01
AIM: To investigate the relationship between low-dose aspirin-induced small bowel mucosal damage and blood flow, and the effect of rebamipide. METHODS: Ten healthy volunteers were enrolled in this study. The subjects were divided into two groups: a placebo group given low-dose aspirin plus placebo and a rebamipide group given low-dose aspirin plus rebamipide for a period of 14 d. Capsule endoscopy and contrast-enhanced ultrasonography were performed before and after administration of drugs. Areas under the curves and peak value of time-intensity curve were calculated. RESULTS: Absolute differences in areas under the curves were -1102.5 (95% CI: -1980.3 to -224.7, P = 0.0194) in the placebo group and -152.7 (95% CI: -1604.2 to 641.6, P = 0.8172) in the rebamipide group. Peak values of time intensity curves were -148.0 (95% CI: -269.4 to -26.2, P = 0.0225) in the placebo group and 28.3 (95% CI: -269.0 to 325.6, P = 0.8343) in the rebamipide group. Capsule endoscopy showed mucosal breaks only in the placebo group. CONCLUSION: Short-term administration of low-dose aspirin is associated with small bowel injuries and blood flow. PMID:21245996
Precision of EM Simulation Based Wireless Location Estimation in Multi-Sensor Capsule Endoscopy
Ye, Yunxing; Aisha, Ain-Ul; Swar, Pranay; Pahlavan, Kaveh
2018-01-01
In this paper, we compute and examine two-way localization limits for an RF endoscopy pill as it passes through an individuals gastrointestinal (GI) tract. We obtain finite-difference time-domain and finite element method-based simulation results position assessment employing time of arrival (TOA). By means of a 3-D human body representation from a full-wave simulation software and lognormal models for TOA propagation from implant organs to body surface, we calculate bounds on location estimators in three digestive organs: stomach, small intestine, and large intestine. We present an investigation of the causes influencing localization precision, consisting of a range of organ properties; peripheral sensor array arrangements, number of pills in cooperation, and the random variations in transmit power of sensor nodes. We also perform a localization precision investigation for the situation where the transmission signal of the antenna is arbitrary with a known probability distribution. The computational solver outcome shows that the number of receiver antennas on the exterior of the body has higher impact on the precision of the location than the amount of capsules in collaboration within the GI region. The large intestine is influenced the most by the transmitter power probability distribution. PMID:29651364
Tang, Xue; Gao, Ju; Yang, Xue; Guo, Xia
2018-06-01
Blue rubber bleb nevus syndrome (BRBNS) is a rare vascular disorder consisting of multifocal venous malformations. Delayed diagnosis or misdiagnosis frequently occurs in patients without typical cutaneous lesions or gastrointestinal bleeding symptoms. This article reports a 10-year case of delayed diagnosis of BRBNS detected by capsule endoscopy. A 15-year-old girl presented with refractory iron-deficiency anemia (IDA) for 10 years, without any hemorrhagic signs or noticeable cutaneous lesions, which led to her obvious physical growth retardation. Capsule endoscopic examination revealed dozens of vascular blebs distributed from the jejunum to the ileum and a site of active bleeding. Hence, she was diagnosed with BRBNS. Laparotomy was performed with resection of the small bowel lesions, and iron supplementation was prescribed for 3 months. Postoperatively, the patient had an uncomplicated course. On follow-up after 3 years, IDA in this patient was cured and she did not require further blood transfusion and showed excellent vigor. A high index of suspicion for BRBNS and adequate endoscopy examination will help to identify the origin of refractory IDA in older children, particularly in patients with vascular lesions of the skin.
Achieving real-time capsule endoscopy (CE) video visualization through panoramic imaging
NASA Astrophysics Data System (ADS)
Yi, Steven; Xie, Jean; Mui, Peter; Leighton, Jonathan A.
2013-02-01
In this paper, we mainly present a novel and real-time capsule endoscopy (CE) video visualization concept based on panoramic imaging. Typical CE videos run about 8 hours and are manually reviewed by physicians to locate diseases such as bleedings and polyps. To date, there is no commercially available tool capable of providing stabilized and processed CE video that is easy to analyze in real time. The burden on physicians' disease finding efforts is thus big. In fact, since the CE camera sensor has a limited forward looking view and low image frame rate (typical 2 frames per second), and captures very close range imaging on the GI tract surface, it is no surprise that traditional visualization method based on tracking and registration often fails to work. This paper presents a novel concept for real-time CE video stabilization and display. Instead of directly working on traditional forward looking FOV (field of view) images, we work on panoramic images to bypass many problems facing traditional imaging modalities. Methods on panoramic image generation based on optical lens principle leading to real-time data visualization will be presented. In addition, non-rigid panoramic image registration methods will be discussed.
Current Status and Research into Overcoming Limitations of Capsule Endoscopy
Kwack, Won Gun; Lim, Yun Jeong
2016-01-01
Endoscopic investigation has a critical role in the diagnosis and treatment of gastrointestinal (GI) diseases. Since 2001, capsule endoscopy (CE) has been available for small-bowel exploration and is under continuous development. During the past decade, CE has achieved impressive improvements in areas such as miniaturization, resolution, and battery life. As a result, CE is currently a first-line tool for the investigation of the small bowel in obscure gastrointestinal bleeding and is a useful alternative to wired enteroscopy. Nevertheless, CE still has several limitations, such as incomplete examination and limited diagnostic and therapeutic capabilities. To resolve these problems, many groups have suggested several models (e.g., controlled CO2 insufflation system, magnetic navigation system, mobile robotic platform, tagging and biopsy equipment, and targeted drug-delivery system), which are in development. In the near future, new technological advances will improve the capabilities of CE and broaden its spectrum of applications not only for the small bowel but also for the colon, stomach, and esophagus. The purpose of this review is to introduce the current status of CE and to review the ongoing development of solutions to address its limitations. PMID:26855917
Precision of EM Simulation Based Wireless Location Estimation in Multi-Sensor Capsule Endoscopy.
Khan, Umair; Ye, Yunxing; Aisha, Ain-Ul; Swar, Pranay; Pahlavan, Kaveh
2018-01-01
In this paper, we compute and examine two-way localization limits for an RF endoscopy pill as it passes through an individuals gastrointestinal (GI) tract. We obtain finite-difference time-domain and finite element method-based simulation results position assessment employing time of arrival (TOA). By means of a 3-D human body representation from a full-wave simulation software and lognormal models for TOA propagation from implant organs to body surface, we calculate bounds on location estimators in three digestive organs: stomach, small intestine, and large intestine. We present an investigation of the causes influencing localization precision, consisting of a range of organ properties; peripheral sensor array arrangements, number of pills in cooperation, and the random variations in transmit power of sensor nodes. We also perform a localization precision investigation for the situation where the transmission signal of the antenna is arbitrary with a known probability distribution. The computational solver outcome shows that the number of receiver antennas on the exterior of the body has higher impact on the precision of the location than the amount of capsules in collaboration within the GI region. The large intestine is influenced the most by the transmitter power probability distribution.
NASA Astrophysics Data System (ADS)
Liu, Xiaoqi; Wang, Chengliang; Bai, Jianying; Liao, Guobin
2018-02-01
Portal hypertensive gastropathy (PHG) is common in gastrointestinal (GI) diseases, and a severe stage of PHG (S-PHG) is a source of gastrointestinal active bleeding. Generally, the diagnosis of PHG is made visually during endoscopic examination; compared with traditional endoscopy, (wireless capsule endoscopy) WCE with noninvasive and painless is chosen as a prevalent tool for visual observation of PHG. However, accurate measurement of WCE images with PHG is a difficult task due to faint contrast and confusing variations in background gastric mucosal tissue for physicians. Therefore, this paper proposes a comprehensive methodology to automatically detect S-PHG images in WCE video to help physicians accurately diagnose S-PHG. Firstly, a rough dominatecolor-tone extraction approach is proposed for better describing global color distribution information of gastric mucosa. Secondly, a hybrid two-layer texture acquisition model is designed by integrating co-occurrence matrix into local binary pattern to depict complex and unique gastric mucosal microstructure local variation. Finally, features of mucosal color and microstructure texture are merged into linear support vector machine to accomplish this automatic classification task. Experiments were implemented on an annotated data set including 1,050 SPHG and 1,370 normal images collected from 36 real patients of different nationalities, ages and genders. By comparison with three traditional texture extraction methods, our method, combined with experimental results, performs best in detection of S-PHG images in WCE video: the maximum of accuracy, sensitivity and specificity reach 0.90, 0.92 and 0.92 respectively.
Saruta, Masayuki; Papadakis, Konstantinos A
2009-01-01
Wireless capsule endoscopy (WCE) has emerged as an important diagnostic tool for the evaluation of patients with suspected small intestinal (SI) disease, including obscure gastrointestinal bleeding, Crohn's disease (CD), malabsorptive disorders and SI tumors. Since a great number of patients with CD have small-bowel (SB) involvement, it is important for newly diagnosed patients to undergo an evaluation of the SB, which has traditionally been performed using a radiographic study such as a SB follow-through. The greatest utility of WCE in the evaluation of SB CD has been observed in cases of suspected CD, where the initial evaluation with upper and lower endoscopy as well as traditional radiographic techniques have failed to establish the diagnosis. WCE can detect SB involvement in CD, particularly early lesions that can be overlooked by traditional radiological studies. The sensitivity of diagnosing SB CD by WCE is superior to other endoscopic or radiological methods such as push enteroscopy, computed tomography or magnetic resonance enteroclysis. The utility of WCE in patients with known CD, indeterminate colitis and a select group of patients with ulcerative colitis can help to better define the diagnosis and extent of the disease, and assist in the management of patients with persistent symptoms. A disadvantage of WCE is that the device may be retained in a strictured area of the SB, which may often be present in patients with CD, in addition to a lower specificity. WCE may replace classical studies and become the gold standard for diagnosing SB involvement in patients with suspected, or known CD, in the absence of strictures and fistulae.
Barbosa, Daniel C; Roupar, Dalila B; Ramos, Jaime C; Tavares, Adriano C; Lima, Carlos S
2012-01-11
Wireless capsule endoscopy has been introduced as an innovative, non-invasive diagnostic technique for evaluation of the gastrointestinal tract, reaching places where conventional endoscopy is unable to. However, the output of this technique is an 8 hours video, whose analysis by the expert physician is very time consuming. Thus, a computer assisted diagnosis tool to help the physicians to evaluate CE exams faster and more accurately is an important technical challenge and an excellent economical opportunity. The set of features proposed in this paper to code textural information is based on statistical modeling of second order textural measures extracted from co-occurrence matrices. To cope with both joint and marginal non-Gaussianity of second order textural measures, higher order moments are used. These statistical moments are taken from the two-dimensional color-scale feature space, where two different scales are considered. Second and higher order moments of textural measures are computed from the co-occurrence matrices computed from images synthesized by the inverse wavelet transform of the wavelet transform containing only the selected scales for the three color channels. The dimensionality of the data is reduced by using Principal Component Analysis. The proposed textural features are then used as the input of a classifier based on artificial neural networks. Classification performances of 93.1% specificity and 93.9% sensitivity are achieved on real data. These promising results open the path towards a deeper study regarding the applicability of this algorithm in computer aided diagnosis systems to assist physicians in their clinical practice.
Colloid cysts of the third ventricle. Endoscopic and open microsurgical management.
Stachura, Krzysztof; Libionka, Witold; Moskała, Marek; Krupa, Mariusz; Polak, Jarosław
2009-01-01
The endoscopic approach to colloid cysts of the third ventricle is receiving increasing interest. However, its effectiveness is a matter of discussion. The aim of the study was to present direct and long-term outcome after endoscopy of colloid cyst vs microsurgery. Medical records of 23 patients with colloid cysts were retrospectively analyzed. This group consists of 10 patients treated endoscopically and 13 patients treated using a transcortical-transventricular approach. Sex and age distributions were similar in both groups. Clinically, symptoms of raised intracranial pressure predominated. All patients had hydrocephalus. Tumour diameter ranged from 1.5 to 3 cm. Mean follow-up period was 31 months. In 6/10 endoscopically treated patients, tumours were completely removed. In 3 patients, small capsule remnants, adherent to the choroid plexus and veins, were left. In one case, a portion of capsule, obstructing the intraventricular foramen, was finally removed microsurgically. Postoperatively, 2 patients complained of memory deficits, which became permanent in one case. One patient developed temporary mutism. In one case, with symptoms of hydrocephalus without colloid cyst recurrence, a ventriculoperitoneal shunt was implanted 6 months after the initial surgery. In all microsurgically treated patients tumours were completely removed. One patient was reoperated because of intracerebral haematoma. Two patients suffered from temporary hemiparesis and 2 developed epilepsy. Within one year after surgery 3 patients were shunted because of hydrocephalus; one patient required antiepileptic treatment. The endoscopic approach to colloid cysts of the third ventricle is safe, effective and carries a low complication rate. Endoscopy may be recommended as a treatment option.
Capsule endoscopy in neoplastic diseases
Pennazio, Marco; Rondonotti, Emanuele; de Franchis, Roberto
2008-01-01
Until recently, diagnosis and management of small-bowel tumors were delayed by the difficulty of access to the small bowel and the poor diagnostic capabilities of the available diagnostic techniques. An array of new methods has recently been developed, increasing the possibility of detecting these tumors at an earlier stage. Capsule endoscopy (CE) appears to be an ideal tool to recognize the presence of neoplastic lesions along this organ, since it is non-invasive and enables the entire small bowel to be visualized. High-quality images of the small-bowel mucosa may be captured and small and flat lesions recognized, without exposure to radiation. Recent studies on a large population of patients undergoing CE have reported small-bowel tumor frequency only slightly above that reported in previous surgical series (range, 1.6%-2.4%) and have also confirmed that the main clinical indication to CE in patients with small-bowel tumors is obscure gastrointestinal (GI) bleeding. The majority of tumors identified by CE are malignant; many were unsuspected and not found by other methods. However, it remains difficult to identify pathology and tumor type based on the lesion’s endoscopic appearance. Despite its limitations, CE provides crucial information leading in most cases to changes in subsequent patient management. Whether the use of CE in combination with other new diagnostic (MRI or multidetector CT enterography) and therapeutic (Push-and-pull enteroscopy) techniques will lead to earlier diagnosis and treatment of these neoplasms, ultimately resulting in a survival advantage and in cost savings, remains to be determined through carefully-designed studies. PMID:18785274
Wireless fluorescence capsule for endoscopy using single photon-based detection
NASA Astrophysics Data System (ADS)
Al-Rawhani, Mohammed A.; Beeley, James; Cumming, David R. S.
2015-12-01
Fluorescence Imaging (FI) is a powerful technique in biological science and clinical medicine. Current FI devices that are used either for in-vivo or in-vitro studies are expensive, bulky and consume substantial power, confining the technique to laboratories and hospital examination rooms. Here we present a miniaturised wireless fluorescence endoscope capsule with low power consumption that will pave the way for future FI systems and applications. With enhanced sensitivity compared to existing technology we have demonstrated that the capsule can be successfully used to image tissue autofluorescence and targeted fluorescence via fluorophore labelling of tissues. The capsule incorporates a state-of-the-art complementary metal oxide semiconductor single photon avalanche detector imaging array, miniaturised optical isolation, wireless technology and low power design. When in use the capsule consumes only 30.9 mW, and deploys very low-level 468 nm illumination. The device has the potential to replace highly power-hungry intrusive optical fibre based endoscopes and to extend the range of clinical examination below the duodenum. To demonstrate the performance of our capsule, we imaged fluorescence phantoms incorporating principal tissue fluorophores (flavins) and absorbers (haemoglobin). We also demonstrated the utility of marker identification by imaging a 20 μM fluorescein isothiocyanate (FITC) labelling solution on mammalian tissue.
Liquid Lens module with wide field-of-view and variable focal length
NASA Astrophysics Data System (ADS)
Seo, Sang Won; Han, Seungoh; Seo, Jun Ho; Choi, Woo Bum; Sung, Man Young
2010-12-01
A novel wide angle and variable-focus imaging module based on a miniaturized liquid lens is presented for capsule endoscopy applications. For these applications, it is desirable to have features such as a wide field of view (FOV), variable focus, small size, and low power consumption, thereby taking full advantage of the miniaturized liquid lens. The proposed imaging module has three aspheric plastic lenses for a wide FOV, and one liquid lens that can change the focal length by as much as 24.5 cm with a bias voltage difference of 23 Vrms for variable focusing. The assembled lens module has an overall length of 8.4 mm and a FOV of 120.5°. The realized imaging module including the proposed lenses is small enough to be inserted into a capsule endoscope, and it is expected to improve the diagnostic capability of capsule endoscopes.
Update on Functional Heartburn
Yamasaki, Takahisa; O’Neil, Jessica
2017-01-01
The definition of functional heartburn has been refined over the years. It is currently described, based upon Rome IV criteria, as typical heartburn symptoms in the presence of normal upper endoscopy findings (including normal biopsies), normal esophageal pH testing, and a negative association between symptoms and reflux events. Functional heartburn is very common, affecting women more than men, and with reflux hypersensitivity makes up the majority of heartburn patients who fail twice-daily proton pump inhibitor therapy. These disorders overlap with other functional gastrointestinal disorders and are often accompanied by psychological comorbidities. Diagnosis is made by using endoscopy with esophageal biopsies, wireless pH capsule, pH-impedance monitoring, and high-resolution esophageal manometry. Additional diagnostic tools that may be of value include magnification endoscopy, chromoendoscopy, narrow-band imaging, autofluorescence imaging, mucosal impedance, impedance baseline values, and histopathology scores. Functional heartburn is primarily treated with neuromodulators. Psychological intervention and complementary and alternative medicine may also play important roles in the treatment of these patients. PMID:29339948
New endoscopic and cytologic tools for cancer surveillance in the digestive tract
Brentnall, Teresa A.; Dominitz, Jason A.
2009-01-01
Synopsis Cancer surveillance is an increasing part of everyday practice in gastrointestinal endoscopy due to the identification of high risk groups from genetic and biomarker testing, genealogic and epidemiologic studies, and the increasing number of cancer survivors. An efficient surveillance program requires a cost-effective means for image-guided cancer detection and biopsy. A laser-based tethered-capsule endoscope with enhanced spectral imaging is introduced for unsedated surveillance of the lower esophagus. An ultrathin version of this same endoscope technology provides a 1.2-mm guidewire with imaging capability and cannula-style tools are proposed for image-guided biopsy. Advanced 3D cell visualization techniques are described for increasing the sensitivity of early cancer diagnosis from hematoxylin-stained cells sampled from the pancreatic and biliary ducts. PMID:19423026
Controversies in colorectal cancer screening.
Pox, Christian P
2014-01-01
Colorectal cancer (CRC) is one of the most common cancers worldwide and a good candidate for screening programmes. However, there is controversy concerning which of the available screening tests should be used. There is general agreement that screening for CRC in the asymptomatic population should begin at the age of 50. Several different screening methods are available which can be separated into those that mainly detect cancers: faecal occult blood tests [guaiac (FOBT) and immunochemical (FIT)], genetic stool tests, blood tests and the M2-pyruvate kinase (M2-PK) test. Methods that detect cancers and polyps are colonoscopy, sigmoidoscopy, CT-colonography (CT-C) and colon capsule endoscopy. The only tests for which a reduction in CRC mortality compared to no screening have been proven in randomized trials are FOBT and sigmoidoscopy. Several trials suggest that FIT are superior to FOBT in terms of detection rates of cancers and advanced adenomas and possibly compliance. There is indirect evidence suggesting efficacy of colonoscopy as a screening test. The role of CT-C is controversial. There is data suggesting a good sensitivity for neoplasia >9 mm with a lower sensitivity for smaller neoplasia. However, radiation exposure is considered a major limitation in some countries. Unresolved questions include the lesion cut-off for referral to colonoscopy and work-up of extracolonic findings. For other methods, like genetic stool testing using newer markers, blood tests, capsule endoscopy and M2-PK, there is currently insufficient data on screening of the asymptomatic population. Key Messages: Colorectal screening is recommended and should be performed in the form of an organized programme. If detection of early-stage cancers is the aim of a screening programme, FIT seem to be superior to FOBT. If detection and removal of adenomas is the aim of a screening programme, endoscopic methods seem to be good alternatives. Sigmoidoscopy is easier to perform but will likely only have an effect on distal cancers. Colonoscopy is more invasive but enables inspection of the whole colon. The role of CT-C, capsule endoscopy, genetic stool tests, blood tests and M2-PK is currently unknown. © 2014 S. Karger AG, Basel.
Gralnek, I M; Rabinovitz, R; Afik, D; Eliakim, R
2006-09-01
Initial studies on esophageal capsule endoscopy (PillCam ESO) reported excellent sensitivity and specificity, but these were followed by mixed results in several subsequent studies, probably due to deviations from the recommended ingestion protocol and the inconvenience of capsule ingestion in the supine position. The aim of this study was therefore to test a simplified ingestion procedure (SIP) for PillCam ESO. Using a cross-over study design, the SIP was prospectively compared with the original ingestion procedure for PillCam ESO in 24 healthy volunteers (15 men, nine women; mean age 44, range 27 - 70) and evaluated for: bubbles/saliva interference at the Z-line, Z-line circumferential visualization (quadrants), and convenience and ease of the ingestion procedure. All Rapid 4 videos were reviewed in a randomized manner and read by an experienced PillCam ESO reader blinded to the ingestion procedure used. It was found that the SIP significantly improved visualization in comparison with the original ingestion procedure, with less interference due to bubbles/saliva observed at the gastroesophageal junction ( P = 0.002) and improved visualization of the Z-line ( P = 0.025). Although the esophageal transit time was significantly faster with the SIP (3 : 45 min vs. 0 : 38 min; P = 0.0001), there were no differences in the number of Z-line frames/images captured. This new, simplified ingestion procedure for PillCam ESO provides significantly improved visualization of the Z-line in healthy volunteers. The overall test characteristics of PillCam ESO using SIP should be tested in patients with esophageal disease.
Multicenter, randomized study to optimize bowel preparation for colon capsule endoscopy
Kastenberg, David; Jr, Wilmot C Burch; Romeo, David P; Kashyap, Pankaj K; Pound, David C; Papageorgiou, Neophytos; Sainz, Ignacio Fernández-Urien; Sokach, Carly E; Rex, Douglas K
2017-01-01
AIM To assess the cleansing efficacy and safety of a new Colon capsule endoscopy (CCE) bowel preparation regimen. METHODS This was a multicenter, prospective, randomized, controlled study comparing two CCE regimens. Subjects were asymptomatic and average risk for colorectal cancer. The second generation CCE system (PillCam® COLON 2; Medtronic, Yoqneam, Israel) was utilized. Preparation regimens differed in the 1st and 2nd boosts with the Study regimen using oral sulfate solution (89 mL) with diatrizoate meglumine and diatrizoate sodium solution (“diatrizoate solution”) (boost 1 = 60 mL, boost 2 = 30 mL) and the Control regimen oral sulfate solution (89 mL) alone. The primary outcome was overall and segmental colon cleansing. Secondary outcomes included safety, polyp detection, colonic transit, CCE completion and capsule excretion ≤ 12 h. RESULTS Both regimens had similar cleansing efficacy for the whole colon (Adequate: Study = 75.9%, Control = 77.3%; P = 0.88) and individual segments. In the Study group, CCE completion was superior (Study = 90.9%, Control = 76.9%; P = 0.048) and colonic transit was more often < 40 min (Study = 21.8%, Control = 4%; P = 0.0073). More Study regimen subjects experienced adverse events (Study = 19.4%, Control = 3.4%; P = 0.0061), and this difference did not appear related to diatrizoate solution. Adverse events were primarily gastrointestinal in nature and no serious adverse events related either to the bowel preparation regimen or the capsule were observed. There was a trend toward higher polyp detection with the Study regimen, but this did not achieve statistical significance for any size category. Mean transit time through the entire gastrointestinal tract, from ingestion to excretion, was shorter with the Study regimen while mean colonic transit times were similar for both study groups. CONCLUSION A CCE bowel preparation regimen using oral sulfate solution and diatrizoate solution as a boost agent is effective, safe, and achieved superior CCE completion. PMID:29358870
Caunedo-Alvarez, A; Gómez-Rodríguez, B J; Romero-Vázquez, J; Argüelles-Arias, F; Romero-Castro, R; García-Montes, J M; Pellicer-Bautista, F J; Herrerías-Gutiérrez, J M
2010-02-01
To evaluate the type, frequency, and severity of macroscopic small bowel mucosal injury after chronic NSAID intake as assessed by capsule endoscopy (CE), as well as to correlate the severity of gastroduodenal and intestinal damage in these patients. A prospective, endoscopist-blind, controlled trial. Sixteen patients (14F/2M; age: 57.06 +/- 10.16 yrs) with osteoarthritis (OA) on chronic therapy with NSAIDs underwent CE and upper gastrointestinal endoscopy (UGE). Seventeen patients with OA (9F/2M; age: 57.47 +/- 9.82 yrs) who did not take NSAIDs were included as a control group. A scale ranging from 0 to 2 (0 = no lesions, 1-minor = red spots or petechiae, denuded areas and/or 1-5 mucosal breaks; 2-major = > 5 mucosal breaks and/or strictures, or hemorrhage) was designed to assess the severity of small bowel mucosal injuries. CE found intestinal lesions in 75% (12/16) of patients in the study group and in 11.76% (2/17) of controls (p < 0.01). Seven out of 16 NSAID consumers (43.75%) and none in the control group (0%) had a major small bowel mucosal injury (p < 0.01). The percentages of patients with grade 1 and 2 gastroduodenopathy in the study group, as assessed by UGE, were 37.14 and 23.81%, respectively. There was no significant difference in the rate of major enteropathy between patients with none or minor gastroduodenal injury, and those with major gastroduodenopathy (43.75 vs. 40%; p = N.S.). Chronic NSAID intake is associated with a high rate of small bowel mucosal injuries. Our data have failed to demonstrate a relationship between the severity of gastroduodenal and intestinal injury.
Detection Rate and Clinical Relevance of Ink Tattooing during Balloon-Assisted Enteroscopy
Ebigbo, A.; Schrempf, M.; Messmann, H.; Gölder, S. K.
2017-01-01
Background and Aims Balloon-assisted enteroscopy (BAE) is a well-established tool in the diagnosis and therapy of small bowel diseases. Ink tattooing of the small bowel is used to mark pathologic lesions or the depth of small bowel insertion. The purpose of this study was to determine the safety, the detection rate, and the clinical relevance of ink tattooing during BAE. Methods We performed a retrospective analysis of all 81 patients who received an ink tattooing during BAE between 2010 and 2015. Results In all patients, ink tattooing was performed with no complications. 26 patients received a capsule endoscopy after BAE. The tattoo could be detected via capsule endoscopy in 19 of these 26 patients. The tattoo of the previous BAE could be detected via opposite BAE in 2 of 11 patients. In 9 patients, ink tattooing influenced the choice of approach for reenteroscopy. In 7 patients, the tattoo was used for intraoperative localization and in 3 patients for intraoperative localization as well as for reenteroscopy. The intraoperative detection rate of the tattoo was 100%. Conclusion Ink tattooing of the small intestine is a safe endoscopic procedure to mark the depth of scope insertion or a pathologic lesion during balloon-assisted enteroscopy. PMID:29230241
Mehmood, Irfan; Sajjad, Muhammad; Baik, Sung Wook
2014-01-01
Wireless capsule endoscopy (WCE) has great advantages over traditional endoscopy because it is portable and easy to use, especially in remote monitoring health-services. However, during the WCE process, the large amount of captured video data demands a significant deal of computation to analyze and retrieve informative video frames. In order to facilitate efficient WCE data collection and browsing task, we present a resource- and bandwidth-aware WCE video summarization framework that extracts the representative keyframes of the WCE video contents by removing redundant and non-informative frames. For redundancy elimination, we use Jeffrey-divergence between color histograms and inter-frame Boolean series-based correlation of color channels. To remove non-informative frames, multi-fractal texture features are extracted to assist the classification using an ensemble-based classifier. Owing to the limited WCE resources, it is impossible for the WCE system to perform computationally intensive video summarization tasks. To resolve computational challenges, mobile-cloud architecture is incorporated, which provides resizable computing capacities by adaptively offloading video summarization tasks between the client and the cloud server. The qualitative and quantitative results are encouraging and show that the proposed framework saves information transmission cost and bandwidth, as well as the valuable time of data analysts in browsing remote sensing data. PMID:25225874
Papamichael, Konstantinos; Karatzas, Pantelis; Theodoropoulos, Ioannis; Kyriakos, Nikos; Archavlis, Emmanuel; Mantzaris, Gerasimos J
2015-01-01
Currently, there is no standardized protocol for bowel preparation before small bowel capsule endoscopy (SBCE). This study aimed to investigate the effect of simethicone combined with polyethylene glycol (PEG) on the visualization quality (VQ) of the SBCE in patients with or without known or suspected Crohn's disease (CD). This observational, prospective, single-center study included consecutive patients undergoing a SBCE between 2007 and 2008. Patients received either a standard bowel cleansing preparation of 2 L PEG and 80 mg simethicone orally 12 and 1 h before SBCE respectively (Group A) or only PEG (Group B). VQ, based on scores for luminal bubbles in frames taken from the small intestine, examination completeness, SBCE diagnostic yield, gastric and small bowel transit times were recorded. Of the 115 patients finally included (Group A, n=56 and Group B, n=59) the cecum was visualized in 103 (89.6%). Simethicone overall improved the VQ in the proximal [OR: 2.43 (95%CI: 1.08-5.45), P=0.032] but not in the distal bowel segment (P=0.064). Nevertheless, this effect was not observed in patients undergoing SBCE for either known or suspected CD. Simethicone as an adjunct to PEG for bowel preparation in patients undergoing SBCE significantly improved the VQ in non-CD patients.
Mehmood, Irfan; Sajjad, Muhammad; Baik, Sung Wook
2014-09-15
Wireless capsule endoscopy (WCE) has great advantages over traditional endoscopy because it is portable and easy to use, especially in remote monitoring health-services. However, during the WCE process, the large amount of captured video data demands a significant deal of computation to analyze and retrieve informative video frames. In order to facilitate efficient WCE data collection and browsing task, we present a resource- and bandwidth-aware WCE video summarization framework that extracts the representative keyframes of the WCE video contents by removing redundant and non-informative frames. For redundancy elimination, we use Jeffrey-divergence between color histograms and inter-frame Boolean series-based correlation of color channels. To remove non-informative frames, multi-fractal texture features are extracted to assist the classification using an ensemble-based classifier. Owing to the limited WCE resources, it is impossible for the WCE system to perform computationally intensive video summarization tasks. To resolve computational challenges, mobile-cloud architecture is incorporated, which provides resizable computing capacities by adaptively offloading video summarization tasks between the client and the cloud server. The qualitative and quantitative results are encouraging and show that the proposed framework saves information transmission cost and bandwidth, as well as the valuable time of data analysts in browsing remote sensing data.
Automatic patient-adaptive bleeding detection in a capsule endoscopy
NASA Astrophysics Data System (ADS)
Jung, Yun Sub; Kim, Yong Ho; Lee, Dong Ha; Lee, Sang Ho; Song, Jeong Joo; Kim, Jong Hyo
2009-02-01
We present a method for patient-adaptive detection of bleeding region for a Capsule Endoscopy (CE) images. The CE system has 320x320 resolution and transmits 3 images per second to receiver during around 10-hour. We have developed a technique to detect the bleeding automatically utilizing color spectrum transformation (CST) method. However, because of irregular conditions like organ difference, patient difference and illumination condition, detection performance is not uniform. To solve this problem, the detection method in this paper include parameter compensation step which compensate irregular image condition using color balance index (CBI). We have investigated color balance through sequential 2 millions images. Based on this pre-experimental result, we defined ΔCBI to represent deviate of color balance compared with standard small bowel color balance. The ΔCBI feature value is extracted from each image and used in CST method as parameter compensation constant. After candidate pixels were detected using CST method, they were labeled and examined with a bleeding character. We tested our method with 4,800 images in 12 patient data set (9 abnormal, 3 normal). Our experimental results show the proposed method achieves (before patient adaptive method : 80.87% and 74.25%, after patient adaptive method : 94.87% and 96.12%) of sensitivity and specificity.
NASA Astrophysics Data System (ADS)
Do, Dukho; Alali, Sanaz; Kang, DongKyun; Tabatabaie, Nima; Lu, Weina; Grant, Catriona N.; Soomro, Amna R.; Nishioka, Norman S.; Rosenberg, Mireille; Hesterberg, Paul E.; Yuan, Qian; Garber, John J.; Katz, Aubrey J.; Shreffler, Wayne G.; Tearney, Guillermo J.
2016-03-01
Eosinophilic Esophagitis (EoE) is caused by food allergies, and defined by histological presence of eosinophil cells in the esophagus. The current gold standard for EoE diagnosis is endoscopy with pinch biopsy to detect more than 15 eosinophils/ High power field (HPF). Biopsy examinations are expensive, time consuming and are difficult to tolerate for patients. Spectrally encoded confocal microscopy (SECM) is a high-speed reflectance confocal microscopy technology capable of imaging individual eosinophils as highly scattering cells (diameter between 8 µm to 15 µm) in the epithelium. Our lab has developed a tethered SECM capsule that can be swallowed by unsedated patients. The capsule acquires large area confocal images, equivalent to more than 30,000 HPFs, as it traverses through the esophagus. In this paper, we present the outcome of a clinical study using the tethered SECM capsule for diagnosing EoE. To date, 32 subjects have been enrolled in this study. 88% of the subjects swallowed the capsules without difficulty and of those who swallowed the capsule, 95% preferred the tethered capsule imaging procedure to sedated endoscopic biopsy. Each imaging session took about 12 ± 2.4 minutes during which 8 images each spanning of 24 ± 5 cm2 of the esophagus were acquired. SECM images acquired from EoE patients showed abundant eosinophils as highly scattering cells in squamous epithelium. Results from this study suggest that the SECM capsule has the potential to become a less-invasive, cost-effective tool for diagnosing EoE and monitoring the response of this disease to therapy.
Tziatzios, Georgios; Gkolfakis, Paraskevas; Hassan, Cesare; Toth, Ervin; Zullo, Angelo; Koulaouzidis, Anastasios; Dimitriadis, George D; Triantafyllou, Konstantinos
2018-03-01
Video capsule endoscopy (VCE) is the first-line diagnostic procedure for investigating obscure gastrointestinal bleeding (OGIB). Different re-bleeding rates following index VCE have been reported among Western and Eastern studies. We conducted a comprehensive literature search to identify studies examining re-bleeding rates after VCE for OGIB. Meta-analysis assessed the pooled proportion of re-bleeding events after VCE for OGIB according to study's origin (Western vs. Eastern) and according to the length of follow-up (≥24 months vs. <24 months). We also calculated the re-bleeding odds ratios (OR; 95% CI) after positive vs. negative index VCE, overt vs. occult initial presentation of bleeding and after interventional treatment for positive index cases, according to the study's origin. We included 46 (30 Western and 16 Eastern) studies with 5796 patients. Significant heterogeneity was detected among meta-analyzed studies. Overall, the pooled re-bleeding rate was similar between Western (29%; 95% CI: 23-34) and Eastern (21%; 95% CI: 15-27) populations, irrespective of the length of follow-up. The odds of re-bleeding was significantly higher after positive as compared to negative index VCE in Eastern studies (OR: 1.77; 95% CI: 1.07-2.94). Application of specific treatment after positive index VCE was associated with lower re-bleeding odds in both Western (OR: 0.37; 95% CI: 0.16-0.87) and Eastern (OR: 0.39; 95% CI: 0.21-0.72) populations. Patients undergoing VCE for OGIB have similar re-bleeding rates in the East and the West, regardless of the length of follow-up. However, increased re-bleeding odds after positive index VCE is observed in Eastern studies. Copyright © 2018 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Lien, Gi-Shih; Wu, Ming-Shun; Chen, Chun-Nan; Liu, Chih-Wen; Suk, Fat-Moon
2018-04-01
Current capsule endoscopy procedures are ineffective for upper gastrointestinal (GI) tract examination because they do not allow for operator-controlled navigation of the capsule. External controllability of a capsule endoscope with an applied magnetic field is a possible solution to this problem. We developed a novel magnetic-assisted capsule endoscope (MACE) system to visualize the entire upper GI tract. The present study evaluated the safety and feasibility of the MACE system for the examination of the upper GI tract, including the esophagus, stomach, and duodenum. The present open clinical study enrolled ten healthy volunteers. All participants swallowed a MACE, and an external magnetic field navigator was used for magnetic capsule manipulation in the upper GI tract. We assessed the maneuverability of the magnetic capsule and completeness of the MACE examination as well as the safety and tolerability of the procedure. The present study enrolled ten healthy volunteers with a mean age and body mass index of 47.7 years and 25.6 kg/m 2 , respectively. One volunteer withdrew because of difficulty in swallowing the capsule. In total, nine volunteers underwent the MACE examination. The average examination time was 27.1 min. The maneuverability of the capsule was assessed as good and fair in 55.6 and 44.4% of the participants, respectively. The overall completeness of the examination in the esophagus, stomach, and duodenum was 100, 85.2, and 86.1%, respectively. No severe adverse events occurred during this study. All participants exhibited satisfactory tolerance of the MACE examination. The MACE system has satisfactory maneuverability and visualization completeness with excellent acceptance and tolerance.
The risk of retention of the capsule endoscope in patients with known or suspected Crohn's disease.
Cheifetz, Adam S; Kornbluth, Asher A; Legnani, Peter; Schmelkin, Ira; Brown, Alphonso; Lichtiger, Simon; Lewis, Blair S
2006-10-01
Capsule endoscopy (CE) allows visualization of the mucosa of the entire small bowel and is therefore a potentially important tool in the evaluation of patients with known or suspected Crohn's disease (CD). However, small bowel strictures, which are not uncommon in Crohn's, are considered to be a contraindication to CE for fear of capsule retention. Our goal was to determine the risk of capsule retention in patients with suspected or known CD. We retrospectively reviewed the records of 983 CE cases performed at three private gastroenterology practices between December 2000 and December 2003, and selected those with suspected or proven Crohn's. A total of 102 cases were identified in which CE was used in patients with suspected (N = 64) or known (N = 38) CD. Only one of 64 patients (1.6%) with suspected CD had a retained capsule. However, in five of 38 (13%) patients with known Crohn's, the capsule was retained proximal to a stricture. Of the five cases of retained capsules, three strictures were previously unknown. In four cases, the obstructing lesions were resected without complications, leading to complete resolution of the patient's underlying symptoms. One patient chose not to undergo surgery and has remained without an episode of small bowel obstruction for over 38 months. Capsule retention occurred in 13% (95% CI 5.6%-28%) of patients with known CD, but only in 1.6% (95% CI 0.2%-10%) with suspected Crohn's. A retained capsule may indicate unsuspected strictures in Crohn's that may require an unexpected, but therapeutic, surgical intervention. Patients and physicians should be aware of these potential risks when using CE in CD.
Mostafalu, Pooria; Sonkusale, Sameer
2014-04-15
In this paper, we present the potential to harvest energy directly from the digestive system for powering a future wireless endoscopy capsule. A microfabricated electrochemical cell on flexible parylene film is proposed as a gastric battery. This electrochemical cell uses gastric juice as a source of unlimited electrolyte. Planar fabricated zinc [Zn] and palladium [Pd] electrodes serve as anode and cathode respectively. Due to planar geometry, no separator is needed. Moreover the annular structure of the electrodes provides lower distance between cathode and anode reducing the internal resistance. Both electrodes are biocompatible and parylene provides flexibility to the system. For a surface area of 15 mm(2), 1.25 mW is generated which is sufficient for most implantable endoscopy applications. Open circuit output voltage of this battery is 0.75 V. Since this gastric battery does not require any external electrolyte, it has low intrinsic weight, and since it is flexible and is made of biocompatible materials, it offers a promising solution for power in implantable applications. © 2013 Published by Elsevier B.V.
Ghosh, Tonmoy; Fattah, Shaikh Anowarul; Wahid, Khan A
2018-01-01
Wireless capsule endoscopy (WCE) is the most advanced technology to visualize whole gastrointestinal (GI) tract in a non-invasive way. But the major disadvantage here, it takes long reviewing time, which is very laborious as continuous manual intervention is necessary. In order to reduce the burden of the clinician, in this paper, an automatic bleeding detection method for WCE video is proposed based on the color histogram of block statistics, namely CHOBS. A single pixel in WCE image may be distorted due to the capsule motion in the GI tract. Instead of considering individual pixel values, a block surrounding to that individual pixel is chosen for extracting local statistical features. By combining local block features of three different color planes of RGB color space, an index value is defined. A color histogram, which is extracted from those index values, provides distinguishable color texture feature. A feature reduction technique utilizing color histogram pattern and principal component analysis is proposed, which can drastically reduce the feature dimension. For bleeding zone detection, blocks are classified using extracted local features that do not incorporate any computational burden for feature extraction. From extensive experimentation on several WCE videos and 2300 images, which are collected from a publicly available database, a very satisfactory bleeding frame and zone detection performance is achieved in comparison to that obtained by some of the existing methods. In the case of bleeding frame detection, the accuracy, sensitivity, and specificity obtained from proposed method are 97.85%, 99.47%, and 99.15%, respectively, and in the case of bleeding zone detection, 95.75% of precision is achieved. The proposed method offers not only low feature dimension but also highly satisfactory bleeding detection performance, which even can effectively detect bleeding frame and zone in a continuous WCE video data.
Polyethylene glycol plus simethicone in small-bowel preparation for capsule endoscopy.
Spada, Cristiano; Riccioni, Maria E; Familiari, Pietro; Spera, Gianluca; Pirozzi, Giuseppe A; Marchese, Michele; Bizzotto, Alessandra; Ingrosso, Marcello; Costamagna, Guido
2010-05-01
Small-bowel contents can hamper the quality of video-capsule endoscopy (VCE). No standardized protocol has been proposed and overnight fasting remains the proposed preparation for VCE. The aim was to evaluate the effects of 2 regimens of bowel preparation on small intestine cleansing, diagnostic yield and capsule transit times. This is a prospective, randomized, blinded, and controlled study. Sixty patients referred for VCE were randomized into 2 groups. Group A ingested 2l of a polyethylene glycol and simethicone solution 16h before VCE. Group B were instructed to consume a fibre-free diet and allowed to consume clear liquids the day before VCE. The small-bowel cleansing was graded as "complete" if the entire wall was assessable, "incomplete" if more than 50% of the wall was visible, and "insufficient" if less than 50% of the wall was visible. In group A, a "complete", "incomplete" and "insufficient" small-bowel cleansing was achieved in 42%, 39% and 19% of cases respectively. In group B, a "complete", "incomplete" and "insufficient" small-bowel cleansing was achieved in 43%, 33% and 24% of cases respectively. No significant differences were observed between the two groups, regarding small-bowel cleansing level (p=0.65). No differences were also observed in the diagnostic yield (48.2%, 13.8% and 38% vs 65.5%, 6.9% and 27.6% of positive, suspicious and no findings respectively, in groups A and B [p=0.39]) and small-bowel transit times (mean 288min and 299 min in groups A and B respectively [p=0.70]). The results of the present study do not support the use of 2l of a polyethylene glycol and simethicone solution before VCE. Copyright 2009 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Myths, fallacies and practical pearls in GI lab
Kumar, Pradeep
2014-01-01
Many prevalent practices and guidelines related to Gastrointestinal endoscopy and procedural sedation are at odds with the widely available scientific-physiological and clinical outcome data. In many institutions, strict policy of pre-procedural extended fasting is still rigorously enforced, despite no evidence of increased incidence of aspiration after recent oral intake prior to sedation. Supplemental oxygen administration in the setting of GI procedural sedation has been increasingly adopted as reported in the medical journals, despite clear evidence that supplemental oxygen blunts the usefulness of pulse oximetry in timely detection of sedation induced hypoventilation, leading to increased number of adverse cardiopulmonary outcomes. Use of Propofol by Gastroenterologist-Nurse team is erroneously considered dangerous and often prohibited in various institutions, at the same time worldwide reports of remarkable safety and patient satisfaction continue to be published, dating back more than a decade. Of patient monitoring practices that have been advocated to be standard, many merely add cost, not value. Advances in the technology often are not incorporated in a timely manner in guidelines or clinical practices, e.g., Capsule endoscopy or electrocautery during GI procedures do not interfere with proper functioning of the current pacemakers or defibrillators. Orthopedic surgeons have continued to recommend prophylactic antibiotics for joint replacement patients prior to GI procedures, without any evidence of need. These myths are explored for a succint review to prompt a change in clinical practices and institutional policies. PMID:25512767
Keller, Jutta; Fibbe, Christiane; Volke, Frank; Gerber, Jeremy; Mosse, Alexander C; Reimann-Zawadzki, Meike; Rabinovitz, Elisha; Layer, Peter; Swain, Paul
2010-11-01
Remote control of esophageal capsule endoscopes could enhance diagnostic accuracy. To assess the safety and efficacy of remote magnetic manipulation of a modified capsule endoscope (magnetic maneuverable capsule [MMC]; Given Imaging Ltd, Yoqneam, Israel) in the esophagus of healthy humans. Randomized, controlled trial. Academic hospital. This study involved 10 healthy volunteers. All participants swallowed a conventional capsule (ESO2; Given Imaging) and a capsule endoscope with magnetic material, the MMC, which is activated by a thermal switch, in random order (1 week apart). An external magnetic paddle (EMP; Given Imaging) was used to manipulate the MMC within the esophageal lumen. MMC responsiveness was evaluated on a screen showing the MMC film in real time. Safety and tolerability of the procedure (questionnaire), responsiveness of the MMC to the EMP, esophageal transit time, and visualization of the Z-line. No adverse events occurred apart from mild retrosternal pressure (n = 5). The ability to rotate the MMC around its longitudinal axis and to tilt it by defined movements of the EMP was clearly demonstrated in 9 volunteers. Esophageal transit time was highly variable for both capsules (MMC, 111-1514 seconds; ESO2, 47-1474 seconds), but the MMC stayed longer in the esophagus in 8 participants (P < .01). Visualization of the Z-line was more efficient with the ESO2 (inspection of 73% ± 18% of the circumference vs 33% ± 27%, P = .01). Magnetic forces were not strong enough to hold the MMC against peristalsis when the capsule approached the gastroesophageal junction. Remote control of the MMC in the esophagus of healthy volunteers is safe and feasible, but higher magnetic forces may be needed. Copyright © 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Gettman, Matthew T; Swain, Paul
2009-05-01
Cystoscopy remains one of the most important diagnostic procedures for the lower urinary tract. Wireless capsule endoscopy was introduced in the 1990s but use to date is limited to gastroenterology. We evaluated the feasibility in the pig model of using wireless capsule endoscopes (WCEs) for cystoscopy. Experimental evaluation of capsule cystoscopy was performed in a 50-kg farm pig. The capsule was deployed into the bladder through a custom access sheath. Images were continuously transmitted at a rate of four frames per second to a laptop computer and processed using proprietary software. Manipulation of the WCE within the bladder was performed using a set protocol. The animal was then euthanized and gross inspection was performed. We measured the ability to deploy and manipulate the capsule within the bladder. Feasibility of capturing and retrieving images in real time was also assessed. The WCE was efficiently deployed and manipulated within the bladder passively and with the use of external magnets. The entire bladder mucosa was visualized. Real-time image transmission and capture were successful. No complications were seen during capsule cystoscopy. Minor urethral bleeding was observed after the experiment, likely related to placement of the access sheath required for deployment of the WCE. Limitations are that the evaluation of WCE was performed in the pig model, in only one female animal, using a nonsurvival approach. Furthermore, the study was not designed to differentiate normal from abnormal mucosal findings and focused solely on inspection of the bladder. This report suggests that cystoscopy with a WCE is feasible. With this device, all aspects of the bladder mucosa could be visualized, and ongoing technologic and procedural developments are warranted for this new approach.
Tethered capsule endomicroscopy: from bench to bedside at a primary care practice
NASA Astrophysics Data System (ADS)
Gora, Michalina J.; Simmons, Leigh H.; Quénéhervé, Lucille; Grant, Catriona N.; Carruth, Robert W.; Lu, Weina; Tiernan, Aubrey; Dong, Jing; Walker-Corkery, Beth; Soomro, Amna; Rosenberg, Mireille; Metlay, Joshua P.; Tearney, Guillermo J.
2016-10-01
Due to the relatively high cost and inconvenience of upper endoscopic biopsy and the rising incidence of esophageal adenocarcinoma, there is currently a need for an improved method for screening for Barrett's esophagus. Ideally, such a test would be applied in the primary care setting and patients referred to endoscopy if the result is suspicious for Barrett's. Tethered capsule endomicroscopy (TCE) is a recently developed technology that rapidly acquires microscopic images of the entire esophagus in unsedated subjects. Here, we present our first experience with clinical translation and feasibility of TCE in a primary care practice. The acceptance of the TCE device by the primary care clinical staff and patients shows the potential of this device to be useful as a screening tool for a broader population.
Ota, Kazuhiro; Takeuchi, Toshihisa; Nouda, Sadaharu; Ozaki, Haruhiko; Kawaguchi, Shinpei; Takahashi, Yoshiaki; Harada, Satoshi; Edogawa, Shoko; Kojima, Yuichi; Kuramoto, Takanori; Higuchi, Kazuhide
2016-11-01
Small intestinal mucosal injury caused by low-dose aspirin is a common cause of obscure gastrointestinal bleeding. We aimed to investigate the protective effects and optimal dose of rebamipide for low-dose aspirin-induced gastrointestinal mucosal injury. In this prospective randomized trial, 45 healthy volunteers (aged 20-65 years) were included and divided into three groups. The groups received enteric-coated aspirin 100 mg (low-dose aspirin) plus omeprazole 10 mg (Group A: proton pump inhibitor group), low-dose aspirin plus rebamipide 300 mg (Group B: standard-dose group), or low-dose aspirin plus rebamipide 900 mg (Group C: high-dose group). Esophagogastroduodenoscopy and video capsule endoscopy were performed, and the fecal occult blood reaction and fecal calprotectin levels were measured before and two weeks after drug administration. Although the fecal calprotectin levels increased significantly in Group A, they did not increase in Groups B and C. The esophagogastroduodenoscopic and video capsule endoscopic findings and the fecal occult blood test findings did not differ significantly among the three groups. In conclusion, standard-dose rebamipide is sufficient for preventing mucosal injury of the small intestine induced by low-dose aspirin, indicating that high-dose rebamipide is not necessary.
Colon Capsule Endoscopy compared to Conventional Colonoscopy under routine screening conditions
2010-01-01
Background Colonoscopy (CSPY) for colorectal cancer screening has several limitations. Colon Capsule Endoscopy (PillCam Colon, CCE) was compared to CSPY under routine screening conditions. Methods We performed a prospective, single-center pilot study at a University Hospital. Data were obtained from November 2007 until May 2008. Patients underwent CCE on Day 1 and CSPY on Day 2. Outcomes were evaluated regarding sensitivity and specificity of polyp detection rate, with a significance level set at >5 mm. Results 59 individuals were included in this study, the results were evaluable in 56 patients (males 34, females 22; median age 59). CCE was complete in 36 subjects. Polyp detection rate for significant polyps was 11% on CSPY and 27% on CCE. 6/56 (11%) patients had polyps on CSPY not detected on CCE (miss rate). Overall sensitivity was 79% (95% confidence interval [CI], 61 to 90), specificity was 54% (95% CI, 35 to 70), positive predictive value (PPV) was 63% and negative predictive value (NPV) was 71%. Adjusted to significance of findings, sensitivity was 50% (95% CI, 19 to 81), specificity was 76% (95% CI, 63 to 86), PPV was 20% and NPV was 93%. Conclusion In comparison to the gold standard, the sensitivity of CCE for detection of relevant polyps is low, however, the high NPV supports its role as a possible screening tool. Trial Registration NCT00991003. PMID:20565828
Coffee Enema for Preparation for Small Bowel Video Capsule Endoscopy: A Pilot Study
Kim, Eun Sun; Keum, Bora; Seo, Yeon Seok; Jeen, Yoon Tae; Lee, Hong Sik; Um, Soon Ho; Kim, Chang Duck; Ryu, Ho Sang
2014-01-01
Coffee enemas are believed to cause dilatation of bile ducts and excretion of bile through the colon wall. Proponents of coffee enemas claim that the cafestol palmitate in coffee enhances the activity of glutathione S-transferase, an enzyme that stimulates bile excretion. During video capsule endoscopy (VCE), excreted bile is one of the causes of poor preparation of the small bowel. This study aimed to evaluate the feasibility and effect of coffee enema for preparation of the small bowel during VCE. In this pilot study, 17 of 34 patients were assigned to the coffee enema plus polyethylene glycol (PEG) 2 L ingestion group, whereas the 17 remaining control patients received 2 L of PEG only. The quality of bowel preparation was evaluated in the two patient groups. Bowel preparations in the proximal segments of small bowel were not differ between two groups. In the mid and distal segments of the small intestine, bowel preparations tend to be better in patients who received coffee enemas plus PEG than in patients who received PEG only. The coffee enema group did not experience any complications or side effects. Coffee enemas may be a feasible option, and there were no clinically significant adverse events related to coffee enemas. More prospective randomized studies are warranted to improve small bowel preparation for VCE. PMID:25136541
Papamichael, Konstantinos; Karatzas, Pantelis; Theodoropoulos, Ioannis; Kyriakos, Nikos; Archavlis, Emmanuel; Mantzaris, Gerasimos J.
2015-01-01
Background Currently, there is no standardized protocol for bowel preparation before small bowel capsule endoscopy (SBCE). This study aimed to investigate the effect of simethicone combined with polyethylene glycol (PEG) on the visualization quality (VQ) of the SBCE in patients with or without known or suspected Crohn’s disease (CD). Methods This observational, prospective, single-center study included consecutive patients undergoing a SBCE between 2007 and 2008. Patients received either a standard bowel cleansing preparation of 2 L PEG and 80 mg simethicone orally 12 and 1 h before SBCE respectively (Group A) or only PEG (Group B). VQ, based on scores for luminal bubbles in frames taken from the small intestine, examination completeness, SBCE diagnostic yield, gastric and small bowel transit times were recorded. Results Of the 115 patients finally included (Group A, n=56 and Group B, n=59) the cecum was visualized in 103 (89.6%). Simethicone overall improved the VQ in the proximal [OR: 2.43 (95%CI: 1.08-5.45), P=0.032] but not in the distal bowel segment (P=0.064). Nevertheless, this effect was not observed in patients undergoing SBCE for either known or suspected CD. Conclusion Simethicone as an adjunct to PEG for bowel preparation in patients undergoing SBCE significantly improved the VQ in non-CD patients. PMID:26423317
Hookworm Infection: A Neglected Cause of Overt Obscure Gastrointestinal Bleeding.
Wei, Kun-Yan; Yan, Qiong; Tang, Bo; Yang, Shi-Ming; Zhang, Peng-Bing; Deng, Ming-Ming; Lü, Mu-Han
2017-08-01
Hookworm infections are widely prevalent in tropical and subtropical areas, especially in low income regions. In the body, hookworms parasitize the proximal small intestine, leading to chronic intestinal hemorrhage and iron deficiency anemia. Occasionally, hookworms can cause overt gastrointestinal bleeding, but this is often ignored in heavily burdened individuals from endemic infectious areas. A total of 424 patients with overt obscure gastrointestinal bleeding were diagnosed by numerous blood tests or stool examinations as well as esophagogastroduodenoscopy, colonoscopy, capsule endoscopy or double-balloon enteroscopy. All of the patients lived in hookworm endemic areas and were not screened for hookworm infection using sensitive tests before the final diagnosis. The patients recovered after albendazole treatment, blood transfusion, and iron replacement, and none of the patients experienced recurrent bleeding in the follow-up. All the 31 patients were diagnosed with hookworm infections without other concomitant bleeding lesions, a rate of 7.3% (31/424). Seventeen out of 227 patients were diagnosed with hookworm infections in the capsule endoscopy (CE), and 14 out of 197 patients were diagnosed with hookworm infections in the double balloon enteroscopy (DBE). Hookworm infections can cause overt gastrointestinal bleeding and should be screened in patients with overt obscure gastrointestinal bleeding (OGIB) in endemic infectious areas with sensitive methods. Specifically, the examination of stool specimens is clinically warranted for most patients, and the proper examination for stool eggs relies on staff's communication.
Controlling the Display of Capsule Endoscopy Video for Diagnostic Assistance
NASA Astrophysics Data System (ADS)
Vu, Hai; Echigo, Tomio; Sagawa, Ryusuke; Yagi, Keiko; Shiba, Masatsugu; Higuchi, Kazuhide; Arakawa, Tetsuo; Yagi, Yasushi
Interpretations by physicians of capsule endoscopy image sequences captured over periods of 7-8 hours usually require 45 to 120 minutes of extreme concentration. This paper describes a novel method to reduce diagnostic time by automatically controlling the display frame rate. Unlike existing techniques, this method displays original images with no skipping of frames. The sequence can be played at a high frame rate in stable regions to save time. Then, in regions with rough changes, the speed is decreased to more conveniently ascertain suspicious findings. To realize such a system, cue information about the disparity of consecutive frames, including color similarity and motion displacements is extracted. A decision tree utilizes these features to classify the states of the image acquisitions. For each classified state, the delay time between frames is calculated by parametric functions. A scheme selecting the optimal parameters set determined from assessments by physicians is deployed. Experiments involved clinical evaluations to investigate the effectiveness of this method compared to a standard-view using an existing system. Results from logged action based analysis show that compared with an existing system the proposed method reduced diagnostic time to around 32.5 ± minutes per full sequence while the number of abnormalities found was similar. As well, physicians needed less effort because of the systems efficient operability. The results of the evaluations should convince physicians that they can safely use this method and obtain reduced diagnostic times.
Ughi, Giovanni J.; Gora, Michalina J.; Swager, Anne-Fré; Soomro, Amna; Grant, Catriona; Tiernan, Aubrey; Rosenberg, Mireille; Sauk, Jenny S.; Nishioka, Norman S.; Tearney, Guillermo J.
2016-01-01
Optical coherence tomography (OCT) is an optical diagnostic modality that can acquire cross-sectional images of the microscopic structure of the esophagus, including Barrett’s esophagus (BE) and associated dysplasia. We developed a swallowable tethered capsule OCT endomicroscopy (TCE) device that acquires high-resolution images of entire gastrointestinal (GI) tract luminal organs. This device has a potential to become a screening method that identifies patients with an abnormal esophagus that should be further referred for upper endoscopy. Currently, the characterization of the OCT-TCE esophageal wall data set is performed manually, which is time-consuming and inefficient. Additionally, since the capsule optics optimally focus light approximately 500 µm outside the capsule wall and the best quality images are obtained when the tissue is in full contact with the capsule, it is crucial to provide feedback for the operator about tissue contact during the imaging procedure. In this study, we developed a fully automated algorithm for the segmentation of in vivo OCT-TCE data sets and characterization of the esophageal wall. The algorithm provides a two-dimensional representation of both the contact map from the data collected in human clinical studies as well as a tissue map depicting areas of BE with or without dysplasia. Results suggest that these techniques can potentially improve the current TCE data acquisition procedure and provide an efficient characterization of the diseased esophageal wall. PMID:26977350
Jacobian-Based Iterative Method for Magnetic Localization in Robotic Capsule Endoscopy
Di Natali, Christian; Beccani, Marco; Simaan, Nabil; Valdastri, Pietro
2016-01-01
The purpose of this study is to validate a Jacobian-based iterative method for real-time localization of magnetically controlled endoscopic capsules. The proposed approach applies finite-element solutions to the magnetic field problem and least-squares interpolations to obtain closed-form and fast estimates of the magnetic field. By defining a closed-form expression for the Jacobian of the magnetic field relative to changes in the capsule pose, we are able to obtain an iterative localization at a faster computational time when compared with prior works, without suffering from the inaccuracies stemming from dipole assumptions. This new algorithm can be used in conjunction with an absolute localization technique that provides initialization values at a slower refresh rate. The proposed approach was assessed via simulation and experimental trials, adopting a wireless capsule equipped with a permanent magnet, six magnetic field sensors, and an inertial measurement unit. The overall refresh rate, including sensor data acquisition and wireless communication was 7 ms, thus enabling closed-loop control strategies for magnetic manipulation running faster than 100 Hz. The average localization error, expressed in cylindrical coordinates was below 7 mm in both the radial and axial components and 5° in the azimuthal component. The average error for the capsule orientation angles, obtained by fusing gyroscope and inclinometer measurements, was below 5°. PMID:27087799
Primary Jejunal Adenocarcinoma Presenting as Bilateral Ovarian Metastasis
Ofori, Emmanuel; Ramai, Daryl; Papafragkakis, Charilaos; Changela, Kinesh; Krishnaiah, Mahesh
2017-01-01
Small intestinal tumors are rare with adenocarcinoma of the small intestine accounting for less than 2% of all gastrointestinal cancers. Primary jejunal adenocarcinoma constitutes a minute portion of small intestine adenocarcinomas. Clinically, this cancer presents at latter stages of its progression, mainly due to vague and non-specific symptoms, and the difficulty encountered in accessing the jejunum on upper endoscopy. Diagnosis of jejunal adenocarcinoma is usually inconclusive with the use of computed tomography (CT) scan, small bowel series, or upper endoscopy. Laparoscopy followed by frozen section biopsy provides a definitive diagnosis. In the past decade, balloon-assisted enteroscopy (BAE) and capsule endoscopy have become popular as useful modalities for diagnosing small bowel diseases. Wide excisional jejunectomy is the only treatment option with an estimated 5-year survival of 40-65%. Physicians are advised to suspect jejunal adenocarcinoma as a differential diagnosis in patients who present with non-specific symptoms of abdominal pain, nausea, vomiting, weight loss, anemia, gastrointestinal bleeding or signs of small bowel obstruction. We present a rare case of a 37-year-old woman with suspected bilateral ovarian masses, which was immunohistochemically confirmed as primary jejunal adenocarcinoma with bilateral ovarian metastasis. PMID:29317945
Primary Jejunal Adenocarcinoma Presenting as Bilateral Ovarian Metastasis.
Ofori, Emmanuel; Ramai, Daryl; Papafragkakis, Charilaos; Changela, Kinesh; Krishnaiah, Mahesh
2017-12-01
Small intestinal tumors are rare with adenocarcinoma of the small intestine accounting for less than 2% of all gastrointestinal cancers. Primary jejunal adenocarcinoma constitutes a minute portion of small intestine adenocarcinomas. Clinically, this cancer presents at latter stages of its progression, mainly due to vague and non-specific symptoms, and the difficulty encountered in accessing the jejunum on upper endoscopy. Diagnosis of jejunal adenocarcinoma is usually inconclusive with the use of computed tomography (CT) scan, small bowel series, or upper endoscopy. Laparoscopy followed by frozen section biopsy provides a definitive diagnosis. In the past decade, balloon-assisted enteroscopy (BAE) and capsule endoscopy have become popular as useful modalities for diagnosing small bowel diseases. Wide excisional jejunectomy is the only treatment option with an estimated 5-year survival of 40-65%. Physicians are advised to suspect jejunal adenocarcinoma as a differential diagnosis in patients who present with non-specific symptoms of abdominal pain, nausea, vomiting, weight loss, anemia, gastrointestinal bleeding or signs of small bowel obstruction. We present a rare case of a 37-year-old woman with suspected bilateral ovarian masses, which was immunohistochemically confirmed as primary jejunal adenocarcinoma with bilateral ovarian metastasis.
Choi, Eric H; Mergener, Klaus; Semrad, Carol; Fisher, Laurel; Cave, David R; Dodig, Milan; Burke, Carol; Leighton, Jonathan A; Kastenberg, David; Simpson, Peter; Sul, James; Bhattacharya, Kanishka; Charles, Roger; Gerson, Lauren; Weber, Luke; Eisen, Glenn; Reidel, Warren; Vargo, John J; Wakim-Fleming, Jamile; Lo, Simon K
2013-08-01
MiroCam, a capsule endoscope, uses a novel transmission technology, electric-field propagation, which uses the human body as a conduction medium for data transmission. To compare the ability of the MiroCam (MC) and PillCam (PC) to identify sources of obscure GI bleeding (OGIB). Prospective, multicenter, comparative study. Six academic hospitals. A total of 105 patients with OGIB. Patients ingested both the MC and PC capsules sequentially in a randomized fashion. Concordance of rates in identifying a source of OGIB, operational times, and rates of complete small-bowel examination. Data analysis resulted in 43 (48%) "abnormal" cases identifying a source of OGIB by either capsule. Twenty-four cases (55.8%) were positive by both capsules. There was negative agreement in 46 of 58 cases (79.3%). The κ index was 0.547 (χ(2) = 1.32; P = .36). In 12 cases, MC positively identified a source that was not seen on PC, whereas in 7 cases, PC positively identified a source that was not seen on MC. MC had a 5.6% higher rate of detecting small-bowel lesions (P = .54). MC captured images at 3 frames per second for 11.1 hours, and PC captured images at 2 frames per second for 7.8 hours (P < .0001). Complete small-bowel examination was achieved in 93.3% for MC and 84.3% for PC (P = .10). Readers were not blinded to the particular capsule they were reading. A positive diagnostic finding for OGIB was identified by either capsule in 48% of cases. The concordance rate between the 2 capsules was comparable to that of prior studies in identifying sources of small-bowel bleeding. The longer operational time of the MC may result in higher rates of complete small-bowel examination, which may, in turn, translate into a higher rate of detecting small-bowel lesions. ( NCT00878982.). Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Friedrich, Kilian; Gehrke, Sven; Stremmel, Wolfgang; Sieg, Andreas
2013-09-01
Capsule endoscopy is the first-line diagnostic technique for the small bowel. However, the inability to visualize the duodenal papilla is an inherent limitation of this method. In the present study, we evaluated feasibility of a newly developed CapsoCam SV1 capsule. This is a prospective dual center study of a newly developed video capsule CapsoCam SV1 from Capsovision, CA, providing panoramic 360° imaging. A high frequency of 20 frames occurs per second for the first 2 h and thereafter 12 frames/s, with a battery life of 15 h. We evaluated feasibility and completeness of small bowel examination together with secondary endpoints of duodenal papilla detection in 33 patients. Patients swallowed the capsules following colonoscopy or were prepared with 2 L of polyethylene glycol solution prior to the examination. All patients swallowed 20 mg of metoclopramide and 160 mg of simethicone 30 min before ingestion of the capsule. Thirty-one of the 33 patients' data could be evaluated. Small bowel examination was complete in all procedures. Mean time to pass the small bowel was 258 ± 136 min. Average small bowel cleanliness was 3.3 ± 0.5. In 71% of the patients, we identified the duodenal papilla. No adverse reaction in relation to the capsule examination was observed. CapsoCam SV1 is a safe and efficient tool in small bowel examination. The duodenal papilla as the only landmark in small bowel is detected in more than 70% of the patients. © 2013 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.
Peritoneal Lipomatosis: A Case Report of a 12-Year-Old Boy
Fotis, L.; Koglmeier, J.; Shah, N.
2013-01-01
Peritoneal lipomatosis is a rare disease in childhood with only two cases previously described in children. We report a further case of a 12-year-old boy diagnosed with peritoneal lipomatosis. His main symptoms were abdominal pain, alternating bowel habit, abdominal distension, and melaena. His diagnostic work up included an abdominal MRI, wireless capsule endoscopy and single-balloon enteroscopy. Peritoneal lipomatosis although rare can be diagnosed in childhood. It is a benign clinical entity with variable manifestations. PMID:23762668
Development of CMOS Imager Block for Capsule Endoscope
NASA Astrophysics Data System (ADS)
Shafie, S.; Fodzi, F. A. M.; Tung, L. Q.; Lioe, D. X.; Halin, I. A.; Hasan, W. Z. W.; Jaafar, H.
2014-04-01
This paper presents the development of imager block to be associated in a capsule endoscopy system. Since the capsule endoscope is used to diagnose gastrointestinal diseases, the imager block must be in small size which is comfortable for the patients to swallow. In this project, a small size 1.5V button battery is used as the power supply while the voltage supply requirements for other components such as microcontroller and CMOS image sensor are higher. Therefore, a voltage booster circuit is proposed to boost up the voltage supply from 1.5V to 3.3V. A low power microcontroller is used to generate control pulses for the CMOS image sensor and to convert the 8-bits parallel data output to serial data to be transmitted to the display panel. The results show that the voltage booster circuit was able to boost the voltage supply from 1.5V to 3.3V. The microcontroller precisely controls the CMOS image sensor to produce parallel data which is then serialized again by the microcontroller. The serial data is then successfully translated to 2fps image and displayed on computer.
Intelligent visual localization of wireless capsule endoscopes enhanced by color information.
Dimas, George; Spyrou, Evaggelos; Iakovidis, Dimitris K; Koulaouzidis, Anastasios
2017-10-01
Wireless capsule endoscopy (WCE) is performed with a miniature swallowable endoscope enabling the visualization of the whole gastrointestinal (GI) tract. One of the most challenging problems in WCE is the localization of the capsule endoscope (CE) within the GI lumen. Contemporary, radiation-free localization approaches are mainly based on the use of external sensors and transit time estimation techniques, with practically low localization accuracy. Latest advances for the solution of this problem include localization approaches based solely on visual information from the CE camera. In this paper we present a novel visual localization approach based on an intelligent, artificial neural network, architecture which implements a generic visual odometry (VO) framework capable of estimating the motion of the CE in physical units. Unlike the conventional, geometric, VO approaches, the proposed one is adaptive to the geometric model of the CE used; therefore, it does not require any prior knowledge about and its intrinsic parameters. Furthermore, it exploits color as a cue to increase localization accuracy and robustness. Experiments were performed using a robotic-assisted setup providing ground truth information about the actual location of the CE. The lowest average localization error achieved is 2.70 ± 1.62 cm, which is significantly lower than the error obtained with the geometric approach. This result constitutes a promising step towards the in-vivo application of VO, which will open new horizons for accurate local treatment, including drug infusion and surgical interventions. Copyright © 2017 Elsevier Ltd. All rights reserved.
Video Capsule Endoscopy: A Tool for the Assessment of Small Bowel Transit Time.
Hejazi, Reza A; Bashashati, Mohammad; Saadi, Mohammed; Mulla, Zuber D; Sarosiek, Irene; McCallum, Richard W; Zuckerman, Marc J
2016-01-01
Video capsule endoscopy (VCE) is a procedure that uses a wireless camera to take pictures of the gastrointestinal (GI) tract. A wireless motility capsule (WMC) of a similar size has been developed, which measures pH, pressure, and temperature and can be used to assess regional and total GI transit times. VCE could also potentially be used as a tool for measuring small bowel transit time (SBTT). This study was designed to obtain SBTT from VCE and compare it with historical data generated by WMC. Gastric transit time (GTT) was also measured. Patients were included if the indication for VCE was either iron deficiency anemia (IDA) or overt obscure GI bleed (OOGIB), and they did not have any known motility disorder. Results from VCE were also compared in diabetic vs. non-diabetic patients. There were a total of 147 VCE studies performed, including 42 for OOGIB and 105 for IDA. Median GTT and SBTT were 0.3 and 3.6 h, respectively. The overall median GTT and SBTT were 0.3 and 3.6 h, respectively, in the IDA group compared with 0.3 and 3.4 h in the OOGIB group. When compared with WMC, the GTT and SBTT were significantly faster in both groups (GTT: 3.6 h and SBTT: 4.6 h). The median GTT and SBTT were not significantly different in diabetics vs. non-diabetics [GTT: 17.5 vs. 18.0 min (P = 0.86) and SBTT: 3.9 h (237 min) vs. 3.8 h (230 min), respectively (P = 0.90)]. SBTT as measured using VCE is not significantly different in OOGIB compared with IDA. Both GTT and SBTT are significantly faster as assessed by VCE, which is initiated in the fasting state, compared with WMC measurement, which is initiated after a standard meal. In summary, VCE could potentially be used for measuring SBTT in the fasting state.
Ghosh, Tonmoy; Wahid, Khan A.
2018-01-01
Wireless capsule endoscopy (WCE) is the most advanced technology to visualize whole gastrointestinal (GI) tract in a non-invasive way. But the major disadvantage here, it takes long reviewing time, which is very laborious as continuous manual intervention is necessary. In order to reduce the burden of the clinician, in this paper, an automatic bleeding detection method for WCE video is proposed based on the color histogram of block statistics, namely CHOBS. A single pixel in WCE image may be distorted due to the capsule motion in the GI tract. Instead of considering individual pixel values, a block surrounding to that individual pixel is chosen for extracting local statistical features. By combining local block features of three different color planes of RGB color space, an index value is defined. A color histogram, which is extracted from those index values, provides distinguishable color texture feature. A feature reduction technique utilizing color histogram pattern and principal component analysis is proposed, which can drastically reduce the feature dimension. For bleeding zone detection, blocks are classified using extracted local features that do not incorporate any computational burden for feature extraction. From extensive experimentation on several WCE videos and 2300 images, which are collected from a publicly available database, a very satisfactory bleeding frame and zone detection performance is achieved in comparison to that obtained by some of the existing methods. In the case of bleeding frame detection, the accuracy, sensitivity, and specificity obtained from proposed method are 97.85%, 99.47%, and 99.15%, respectively, and in the case of bleeding zone detection, 95.75% of precision is achieved. The proposed method offers not only low feature dimension but also highly satisfactory bleeding detection performance, which even can effectively detect bleeding frame and zone in a continuous WCE video data. PMID:29468094
Microultrasound characterisation of ex vivo porcine tissue for ultrasound capsule endoscopy
NASA Astrophysics Data System (ADS)
Lay, H. S.; Cox, B. F.; Sunoqrot, M.; Démoré, C. E. M.; Näthke, I.; Gomez, T.; Cochran, S.
2017-01-01
Gastrointestinal (GI) disease development and progression is often characterised by cellular and tissue architectural changes within the mucosa and sub-mucosa layers. Current clinical capsule endoscopy and other approaches are heavily reliant on optical techniques which cannot detect disease progression below the surface layer of the tissue. To enhance the ability of clinicians to detect cellular changes earlier and more confidently, both quantitative and qualitative microultrasound (μUS) techniques are investigated in healthy ex vivo porcine GI tissue. This work is based on the use of single-element, focussed μUS transducers made with micromoulded piezocomposite operating at around 48 MHz. To explore the possibility that μUS can detect Crohn’s disease and other inflammatory bowel diseases, ex vivo porcine small bowel tissue samples were cannulised and perfused with phosphate-buffered saline followed by various dilutions of polystyrene microspheres. Comparison with fluorescent imaging showed that the microspheres had infiltrated the microvasculature of the samples and that μUS was able to successfully detect this as a mimic of inflammation. Samples without microspheres were analysed using quantitative ultrasound to assess mechanical properties. Attenuation coefficients of 1.78 ± 0.66 dB/mm and 1.92 ± 0.77 dB/mm were obtained from reference samples which were surgically separated from the muscle layer. Six intact samples were segmented using a software algorithm and the acoustic impedance, Z, for varying tissue thicknesses, and backscattering coefficient, BSC, were calculated using the reference attenuation values and tabulated.
KID Project: an internet-based digital video atlas of capsule endoscopy for research purposes.
Koulaouzidis, Anastasios; Iakovidis, Dimitris K; Yung, Diana E; Rondonotti, Emanuele; Kopylov, Uri; Plevris, John N; Toth, Ervin; Eliakim, Abraham; Wurm Johansson, Gabrielle; Marlicz, Wojciech; Mavrogenis, Georgios; Nemeth, Artur; Thorlacius, Henrik; Tontini, Gian Eugenio
2017-06-01
Capsule endoscopy (CE) has revolutionized small-bowel (SB) investigation. Computational methods can enhance diagnostic yield (DY); however, incorporating machine learning algorithms (MLAs) into CE reading is difficult as large amounts of image annotations are required for training. Current databases lack graphic annotations of pathologies and cannot be used. A novel database, KID, aims to provide a reference for research and development of medical decision support systems (MDSS) for CE. Open-source software was used for the KID database. Clinicians contribute anonymized, annotated CE images and videos. Graphic annotations are supported by an open-access annotation tool (Ratsnake). We detail an experiment based on the KID database, examining differences in SB lesion measurement between human readers and a MLA. The Jaccard Index (JI) was used to evaluate similarity between annotations by the MLA and human readers. The MLA performed best in measuring lymphangiectasias with a JI of 81 ± 6 %. The other lesion types were: angioectasias (JI 64 ± 11 %), aphthae (JI 64 ± 8 %), chylous cysts (JI 70 ± 14 %), polypoid lesions (JI 75 ± 21 %), and ulcers (JI 56 ± 9 %). MLA can perform as well as human readers in the measurement of SB angioectasias in white light (WL). Automated lesion measurement is therefore feasible. KID is currently the only open-source CE database developed specifically to aid development of MDSS. Our experiment demonstrates this potential.
Niv, Yaron; Gal, Eyal; Gabovitz, Violeta; Hershkovitz, Marcela; Lichtenstein, Lev; Avni, Irit
2018-01-01
Crohn's disease (CD) is a chronic inflammatory disorder defined as a transmural inflammation of the bowel wall, affecting the small and large intestine. The Capsule Endoscopy Crohn's Disease Activity Index (CECDAI or Niv score) was devised to measure mucosal disease activity. We extended the Niv score to the colon and have a comprehensive view of the whole intestine. We evaluated 3 parameters of intestinal pathology: A, Inflammation; B, Extent of disease; C, Presence of strictures. The scoring formula is as follows: CEDCAIic=(A1×B1+C1)+(A2×B2+C2)+(A3×B3+C3)+(A4×B4+C4) (1=proximal small bowel, 2=distal small bowel, 3=right colon, 4=left colon). The median CECDAIic score was 15.5 (range, 0 to 42), and the mean±SD score was 17.2±11.5. The CECDAIic scores per patient were similar among the 5 observers. Kendall's coefficient of concordance was high and significant for almost all the parameters examined except for strictures in the proximal small bowel and distal colon. Nevertheless, the coefficients for the small bowel and for the whole intestine were high, 0.85 and 0.77, P<0.0001, respectively. We established a new score, the CECDAIic of the small-bowel and colonic CD. We offer this easy, user-friendly score for use in randomized controlled trials and in the clinical follow-up of CD patients.
Hong-Bin, Chen; Yue, Huang; Chun, Huang; Shu-Ping, Xiao; Yue, Zhang; Xiao-Lin, Li
2016-01-01
Background/Aims: Bile is the main cause of poor bowel preparation for capsule endoscopy (CE). We aimed to determine whether cholestyramine and hydrotalcite can eliminate bile in the bowel. Patients and Methods: Patients undergoing CE were randomized into two groups. Group A patients (n = 75) recieved 250 mL 20% mannitol and 1 L 0.9% saline orally at 20:00 hours on the day before and at 05:00 hours on the day of CE and 20 mL simethicone 30 min before CE. Group B patients (n = 73) were treated identically, except for taking oral cholestyramine and hydrotalcite, starting 3 days before CE. Greenish luminal contents were assessed by four tissue color bar segments using Color Area Statistics software. Bowel cleanliness was evaluated by visualized area percentage assessment of cleansing (AAC) score. Result: Bowel cleanliness (82.7% [62/75] vs 46.6% [34/73]; χ2 = 14.596, P = 0.000). and detected greenish luminal contents (20.0% [15/75] vs 8.2% [6/73]; χ2 = 4.217, P = 0.040) were significantly greater in Group A than in Group B. Greenish luminal contents in the two groups differed significantly in the captured small-bowel (t = −13.74, P = 0.000) segments and proximal small-bowel (t = −0.7365, P = 0.000) segments, but not for the distal small-bowel (t = −0.552, P = 0.581) segments. Conclusions: Cholestyramine and hydrotalcite were ineffective in eliminating bile and improving small-bowel preparation. PMID:26997218
Chen, Hong-bin; Huang, Yue; Chen, Su-yu; Song, Hui-wen; Li, Xiao-lin; Dai, Dong-lin; Xie, Jia-tia; He, Song; Zhao, Yuan-yuan; Huang, Chun; Zhang, Sheng-jun; Yang, Lin-na
2011-04-01
There is no consensus concerning small bowel preparation before capsule endoscopy (CE). This study evaluated the effects of 4 regimens on small bowel cleansing and diagnostic yield. Patients were randomly divided into 4 groups. Group A consumed a clear liquid diet after lunch on the day before CE, followed by overnight fasting. Group B took 250 mL 20% mannitol and 1 L 0.9% saline orally at 05:00 hours on the day of the procedure. In group C, the same regimen was taken at 20:00 hours on the day before and at 05:00 hours on the day of CE. In group D, in addition to the group C regimen, 20 mL oral simethicone was taken 30 minutes before CE. Two hundred patients were prospectively enrolled, and 7 were excluded from the final analysis because of incomplete small bowel transit. No significant difference was noted among the 4 groups for small bowel transit time. Bowel preparation in group D was significantly better than for the other regimens for overall cleansing of the proximal small bowel, and showed improved overall cleansing of the distal small bowel when compared with 10-hours overnight fasting. Pathological lesions of the proximal and distal small bowel were, respectively, achieved in 82 and 74 patients, mostly distributed in group D. Small bowel preparation that involves split-dose oral mannitol plus single-dose simethicone for CE can improve mucosal visualization and subsequent diagnostic yield when compared with 10-hours overnight fasting.
A clinically viable capsule endoscopy video analysis platform for automatic bleeding detection
NASA Astrophysics Data System (ADS)
Yi, Steven; Jiao, Heng; Xie, Jean; Mui, Peter; Leighton, Jonathan A.; Pasha, Shabana; Rentz, Lauri; Abedi, Mahmood
2013-02-01
In this paper, we present a novel and clinically valuable software platform for automatic bleeding detection on gastrointestinal (GI) tract from Capsule Endoscopy (CE) videos. Typical CE videos for GI tract run about 8 hours and are manually reviewed by physicians to locate diseases such as bleedings and polyps. As a result, the process is time consuming and is prone to disease miss-finding. While researchers have made efforts to automate this process, however, no clinically acceptable software is available on the marketplace today. Working with our collaborators, we have developed a clinically viable software platform called GISentinel for fully automated GI tract bleeding detection and classification. Major functional modules of the SW include: the innovative graph based NCut segmentation algorithm, the unique feature selection and validation method (e.g. illumination invariant features, color independent features, and symmetrical texture features), and the cascade SVM classification for handling various GI tract scenes (e.g. normal tissue, food particles, bubbles, fluid, and specular reflection). Initial evaluation results on the SW have shown zero bleeding instance miss-finding rate and 4.03% false alarm rate. This work is part of our innovative 2D/3D based GI tract disease detection software platform. While the overall SW framework is designed for intelligent finding and classification of major GI tract diseases such as bleeding, ulcer, and polyp from the CE videos, this paper will focus on the automatic bleeding detection functional module.
GISentinel: a software platform for automatic ulcer detection on capsule endoscopy videos
NASA Astrophysics Data System (ADS)
Yi, Steven; Jiao, Heng; Meng, Fan; Leighton, Jonathon A.; Shabana, Pasha; Rentz, Lauri
2014-03-01
In this paper, we present a novel and clinically valuable software platform for automatic ulcer detection on gastrointestinal (GI) tract from Capsule Endoscopy (CE) videos. Typical CE videos take about 8 hours. They have to be reviewed manually by physicians to detect and locate diseases such as ulcers and bleedings. The process is time consuming. Moreover, because of the long-time manual review, it is easy to lead to miss-finding. Working with our collaborators, we were focusing on developing a software platform called GISentinel, which can fully automated GI tract ulcer detection and classification. This software includes 3 parts: the frequency based Log-Gabor filter regions of interest (ROI) extraction, the unique feature selection and validation method (e.g. illumination invariant feature, color independent features, and symmetrical texture features), and the cascade SVM classification for handling "ulcer vs. non-ulcer" cases. After the experiments, this SW gave descent results. In frame-wise, the ulcer detection rate is 69.65% (319/458). In instance-wise, the ulcer detection rate is 82.35%(28/34).The false alarm rate is 16.43% (34/207). This work is a part of our innovative 2D/3D based GI tract disease detection software platform. The final goal of this SW is to find and classification of major GI tract diseases intelligently, such as bleeding, ulcer, and polyp from the CE videos. This paper will mainly describe the automatic ulcer detection functional module.
Developing assessment system for wireless capsule endoscopy videos based on event detection
NASA Astrophysics Data System (ADS)
Chen, Ying-ju; Yasen, Wisam; Lee, Jeongkyu; Lee, Dongha; Kim, Yongho
2009-02-01
Along with the advancing of technology in wireless and miniature camera, Wireless Capsule Endoscopy (WCE), the combination of both, enables a physician to diagnose patient's digestive system without actually perform a surgical procedure. Although WCE is a technical breakthrough that allows physicians to visualize the entire small bowel noninvasively, the video viewing time takes 1 - 2 hours. This is very time consuming for the gastroenterologist. Not only it sets a limit on the wide application of this technology but also it incurs considerable amount of cost. Therefore, it is important to automate such process so that the medical clinicians only focus on interested events. As an extension from our previous work that characterizes the motility of digestive tract in WCE videos, we propose a new assessment system for energy based events detection (EG-EBD) to classify the events in WCE videos. For the system, we first extract general features of a WCE video that can characterize the intestinal contractions in digestive organs. Then, the event boundaries are identified by using High Frequency Content (HFC) function. The segments are classified into WCE event by special features. In this system, we focus on entering duodenum, entering cecum, and active bleeding. This assessment system can be easily extended to discover more WCE events, such as detailed organ segmentation and more diseases, by using new special features. In addition, the system provides a score for every WCE image for each event. Using the event scores, the system helps a specialist to speedup the diagnosis process.
Day, Lukejohn W; Belson, David; Dessouky, Maged; Hawkins, Caitlin; Hogan, Michael
2014-11-01
Improvements in endoscopy center efficiency are needed, but scant data are available. To identify opportunities to improve patient throughput while balancing resource use and patient wait times in a safety-net endoscopy center. Safety-net endoscopy center. Outpatients undergoing endoscopy. A time and motion study was performed and a discrete event simulation model constructed to evaluate multiple scenarios aimed at improving endoscopy center efficiency. Procedure volume and patient wait time. Data were collected on 278 patients. Time and motion study revealed that 53.8 procedures were performed per week, with patients spending 2.3 hours at the endoscopy center. By using discrete event simulation modeling, a number of proposed changes to the endoscopy center were assessed. Decreasing scheduled endoscopy appointment times from 60 to 45 minutes led to a 26.4% increase in the number of procedures performed per week, but also increased patient wait time. Increasing the number of endoscopists by 1 each half day resulted in increased procedure volume, but there was a concomitant increase in patient wait time and nurse utilization exceeding capacity. By combining several proposed scenarios together in the simulation model, the greatest improvement in performance metrics was created by moving patient endoscopy appointments from the afternoon to the morning. In this simulation at 45- and 40-minute appointment times, procedure volume increased by 30.5% and 52.0% and patient time spent in the endoscopy center decreased by 17.4% and 13.0%, respectively. The predictions of the simulation model were found to be accurate when compared with actual changes implemented in the endoscopy center. Findings may not be generalizable to non-safety-net endoscopy centers. The combination of minor, cost-effective changes such as reducing appointment times, minimizing and standardizing recovery time, and making small increases in preprocedure ancillary staff maximized endoscopy center efficiency across a number of performance metrics. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Oral purgative and simethicone before small bowel capsule endoscopy
Rosa, Bruno Joel Ferreira; Barbosa, Mara; Magalhães, Joana; Rebelo, Ana; Moreira, Maria João; Cotter, José
2013-01-01
AIM: To evaluate small bowel cleansing quality, diagnostic yield and transit time, comparing three cleansing protocols prior to capsule endoscopy. METHODS: Sixty patients were prospectively enrolled and randomized to one of the following cleansing protocols: patients in Group A underwent a 24 h liquid diet and overnight fasting; patients in Group B followed protocol A and subsequently were administered 2 L of polyethylene glycol (PEG) the evening before the procedure; patients in Group C followed protocol B and were additionally administered 100 mg of simethicone 30 min prior to capsule ingestion. Small bowel cleansing was independently assessed by two experienced endoscopists and classified as poor, fair, good or excellent according to the proportion of small bowel mucosa under perfect conditions for visualization. When there was no agreement between the two endoscopists, the images were reviewed and discussed until a consensus was reached. The preparation was considered acceptable if > 50% or adequate if > 75% of the mucosa was in perfect cleansing condition. The amount of bubbles was assessed independently and it was considered significant if it prevented a correct interpretation of the images. Positive endoscopic findings, gastric emptying time (GET) and small bowel transit time (SBTT) were recorded for each examination. RESULTS: There was a trend favoring Group B in achieving an acceptable (including fair, good or excellent) level of cleansing (Group A: 65%; Group B: 83.3%; Group C: 68.4%) [P = not significant (NS)] and favoring Group C in attaining an excellent level of cleansing (Group A: 10%; Group B: 16.7%; Group C: 21.1%) (P = NS). The number of patients with an adequate cleansing of the small bowel, corresponding to an excellent or good classification, was 5 (25%) in Group A, 5 (27.8%) in Group B and 4 (21.1%) in Group C (P = 0.892). Conversely, 7 patients (35%) in Group A, 3 patients (16.7%) in Group B and 6 patients (31.6%) in Group C were considered to have poor small bowel cleansing (P = 0.417), with significant fluid or debris such that the examination was unreliable. The proportion of patients with a significant amount of bubbles was 50% in Group A, 27.8% in Group B and 15.8% in Group C (P = 0.065). This was significantly lower in Group C when compared to Group A (P = 0.026). The mean GET was 27.8 min for Group A, 27.2 min for Group B and 40.7 min for Group C (P = 0.381). The mean SBTT was 256.4 min for Group A, 256.1 min for Group B and 258.1 min for Group C (P = 0.998). Regarding to the rate of complete examinations, the capsule reached the cecum in 20 patients (100%) in Group A, 16 patients (88.9%) in Group B and 17 patients (89.5%) in Group C (P = 0.312). A definite diagnosis based on relevant small bowel endoscopic lesions was established in 60% of the patients in Group A (12 patients), 44.4% in Group B (8 patients) and 57.8% in Group C (11 patients) (P = 0.587). CONCLUSION: Preparation with 2 L of PEG before small bowel capsule endoscopy (SBCE) may improve small bowel cleansing and the quality of visualization. Simethicone may further reduce intraluminal bubbles. No significant differences were found regarding GET, SBTT and the proportion of complete exploration or diagnostic yield among the three different cleansing protocols. PMID:23424190
Oral purgative and simethicone before small bowel capsule endoscopy.
Rosa, Bruno Joel Ferreira; Barbosa, Mara; Magalhães, Joana; Rebelo, Ana; Moreira, Maria João; Cotter, José
2013-02-16
To evaluate small bowel cleansing quality, diagnostic yield and transit time, comparing three cleansing protocols prior to capsule endoscopy. Sixty patients were prospectively enrolled and randomized to one of the following cleansing protocols: patients in Group A underwent a 24 h liquid diet and overnight fasting; patients in Group B followed protocol A and subsequently were administered 2 L of polyethylene glycol (PEG) the evening before the procedure; patients in Group C followed protocol B and were additionally administered 100 mg of simethicone 30 min prior to capsule ingestion. Small bowel cleansing was independently assessed by two experienced endoscopists and classified as poor, fair, good or excellent according to the proportion of small bowel mucosa under perfect conditions for visualization. When there was no agreement between the two endoscopists, the images were reviewed and discussed until a consensus was reached. The preparation was considered acceptable if > 50% or adequate if > 75% of the mucosa was in perfect cleansing condition. The amount of bubbles was assessed independently and it was considered significant if it prevented a correct interpretation of the images. Positive endoscopic findings, gastric emptying time (GET) and small bowel transit time (SBTT) were recorded for each examination. There was a trend favoring Group B in achieving an acceptable (including fair, good or excellent) level of cleansing (Group A: 65%; Group B: 83.3%; Group C: 68.4%) [P = not significant (NS)] and favoring Group C in attaining an excellent level of cleansing (Group A: 10%; Group B: 16.7%; Group C: 21.1%) (P = NS). The number of patients with an adequate cleansing of the small bowel, corresponding to an excellent or good classification, was 5 (25%) in Group A, 5 (27.8%) in Group B and 4 (21.1%) in Group C (P = 0.892). Conversely, 7 patients (35%) in Group A, 3 patients (16.7%) in Group B and 6 patients (31.6%) in Group C were considered to have poor small bowel cleansing (P = 0.417), with significant fluid or debris such that the examination was unreliable. The proportion of patients with a significant amount of bubbles was 50% in Group A, 27.8% in Group B and 15.8% in Group C (P = 0.065). This was significantly lower in Group C when compared to Group A (P = 0.026). The mean GET was 27.8 min for Group A, 27.2 min for Group B and 40.7 min for Group C (P = 0.381). The mean SBTT was 256.4 min for Group A, 256.1 min for Group B and 258.1 min for Group C (P = 0.998). Regarding to the rate of complete examinations, the capsule reached the cecum in 20 patients (100%) in Group A, 16 patients (88.9%) in Group B and 17 patients (89.5%) in Group C (P = 0.312). A definite diagnosis based on relevant small bowel endoscopic lesions was established in 60% of the patients in Group A (12 patients), 44.4% in Group B (8 patients) and 57.8% in Group C (11 patients) (P = 0.587). Preparation with 2 L of PEG before small bowel capsule endoscopy (SBCE) may improve small bowel cleansing and the quality of visualization. Simethicone may further reduce intraluminal bubbles. No significant differences were found regarding GET, SBTT and the proportion of complete exploration or diagnostic yield among the three different cleansing protocols.
Prevention and management of non-steroidal anti-inflammatory drugs-induced small intestinal injury
Park, Sung Chul; Chun, Hoon Jai; Kang, Chang Don; Sul, Donggeun
2011-01-01
Non-steroidal anti-inflammatory drug (NSAID)-induced small bowel injury is a topic that deserves attention since the advent of capsule endoscopy and balloon enteroscopy. NSAID enteropathy is common and is mostly asymptomatic. However, massive bleeding, stricture, or perforation may occur. The pathogenesis of small intestine injury by NSAIDs is complex and different from that of the upper gastrointestinal tract. No drug has yet been developed that can completely prevent or treat NSAID enteropathy. Therefore, a long-term randomized study in chronic NSAID users is needed. PMID:22180706
Gastric form of alpha chain disease.
Coulbois, J; Galian, P; Galian, A; Couteaux, B; Danon, F; Rambaud, J
1986-01-01
A case of alpha chain disease, involving the stomach only, is reported in an Algerian man suffering from epigastric pains. Upper digestive tract fibreoptic endoscopy showed two antral ulcers and an ulcerative gastritis pattern, which promptly disappeared with cimetidine treatment. Antral biopsies at a distance from the ulcers, but not of the ulcer crater itself, disclosed a dense infiltration of antral lamina propria by mature or sometimes atypical plasma cells. On transmural surgical antral biopsy, the infiltrate spread to the superficial part of the submucosa. No other localisation of the disease was found in spite of multiple biopsies obtained by endoscopy, with a peroral capsule and during staging laparotomy. The alpha chain disease protein was absent from serum and urine, but found in the gastric juice and in the cytoplasma of the cellular infiltrate (alpha 1 subclass). A complete clinical, endoscopic, histological and immunological remission was observed after a six months' course of oral tetracycline. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 PMID:3087826
Iacob, Razvan; Dimitriu, Anca; Stanciulea, Oana; Herlea, Vlad; Popescu, Irinel; Gheorghe, Cristian
2016-03-01
We present the case of a 63-year-old man that was admitted for melena and severe anemia. Upper GI endoscopy and colonoscopy failed to identify the lesion responsible for bleeding, and enteroCT scan was also non-contributive to the diagnosis. Capsule endoscopy indicated possible jejunal bleeding but could not indicate the source of bleeding, recommending anterograde enteroscopy. Single balloon enteroscopy identified a 2 cm submucosal tumour in the distal part of the jejunum, with a macroscopic appearance suggesting a gastrointestinal stromal tumour (GIST). The tumor location was marked using SPOT tattoo and subsequently easily identified by the surgeon and resected via minimally invasive laparoscopic-assisted approach. Histological and immunohistochemical analysis indicated a low risk GIST. The unusual small size of the GIST as a modality of presentation, with digestive bleeding and anemia and the ability to use VCE/enteroscopy to identify and mark the lesion prior to minimally invasive surgery, represent the particularities of the presented case.
KID Project: an internet-based digital video atlas of capsule endoscopy for research purposes
Koulaouzidis, Anastasios; Iakovidis, Dimitris K.; Yung, Diana E.; Rondonotti, Emanuele; Kopylov, Uri; Plevris, John N.; Toth, Ervin; Eliakim, Abraham; Wurm Johansson, Gabrielle; Marlicz, Wojciech; Mavrogenis, Georgios; Nemeth, Artur; Thorlacius, Henrik; Tontini, Gian Eugenio
2017-01-01
Background and aims Capsule endoscopy (CE) has revolutionized small-bowel (SB) investigation. Computational methods can enhance diagnostic yield (DY); however, incorporating machine learning algorithms (MLAs) into CE reading is difficult as large amounts of image annotations are required for training. Current databases lack graphic annotations of pathologies and cannot be used. A novel database, KID, aims to provide a reference for research and development of medical decision support systems (MDSS) for CE. Methods Open-source software was used for the KID database. Clinicians contribute anonymized, annotated CE images and videos. Graphic annotations are supported by an open-access annotation tool (Ratsnake). We detail an experiment based on the KID database, examining differences in SB lesion measurement between human readers and a MLA. The Jaccard Index (JI) was used to evaluate similarity between annotations by the MLA and human readers. Results The MLA performed best in measuring lymphangiectasias with a JI of 81 ± 6 %. The other lesion types were: angioectasias (JI 64 ± 11 %), aphthae (JI 64 ± 8 %), chylous cysts (JI 70 ± 14 %), polypoid lesions (JI 75 ± 21 %), and ulcers (JI 56 ± 9 %). Conclusion MLA can perform as well as human readers in the measurement of SB angioectasias in white light (WL). Automated lesion measurement is therefore feasible. KID is currently the only open-source CE database developed specifically to aid development of MDSS. Our experiment demonstrates this potential. PMID:28580415
Chandrasekar, T S; Janakan, Gokul Bollu; Chandrasekar, Viveksandeep Thoguluva; Kalamegam, Raja Yogesh; Suriyanarayanan, Sathiamoorthy; Sanjeevaraya, Prasad Menta
2017-01-01
Bleeding from small intestinal ectopic varices and persistent anemia caused by portal hypertensive enteropathy (PHE) can be very challenging. Capsule endoscopy (CE) is one of the best noninvasive modalities in identifying such lesions. The aims of this study are to study the prevalence of small-bowel changes related to portal hypertension (PHT) and to correlate them with the observations related to the effects of portal hypertension in the esophagus, stomach, and colon. Thirty-two patients with various etiologies of PHT with either anemia or gastrointestinal bleed were included along with age- and sex-matched controls without PHT. All patients underwent blood tests, gastroscopy, colonoscopy, and CE. The small-bowel findings by CE were categorized as inflammatory-like and vascular lesions. The small-bowel changes were analyzed to find out any association with various demographic, clinical, and endoscopic variables. Thirty-one out of 32 patients with PHT (96.8%) had PHE identified by CE. Of them, 31 (96.8%) had inflammatory-like appearance, 11 (34.4%) had vascular lesions, and 2 (6.2%) had small-bowel varices. Inflammatory-like appearance was noted in eight (25%) and angiodysplastic lesions in two (6.2%) controls. Findings compatible with PHE were detected in 96.8% of the patients and 25% of the controls (X 2 =34.72, p=0.000).The presence of PHE was not associated with any of the above-mentioned variables. Small-bowel mucosal changes were seen in significantly higher number of patients with PHT with anemia.
Small bowel video capsule endoscopy in Crohn's disease: What have we learned in the last ten years?
Lucendo, Alfredo J; Guagnozzi, Danila
2011-02-16
Since its introduction in 2001, capsule endoscopy (CE) has become the most important advance in the study of small bowel disease, including Crohn's disease (CD). This technique has been demonstrated to be superior to all other current forms of radiological investigation in detecting mucosal abnormalities of small bowel nonstricturing CD. CE has proven to be extremely useful in diagnosing CD in patients with inconclusive findings from ileocolonoscopy and x-ray-based studies. Almost half of all patients with CD involving the ileum also present lesions in proximal intestinal segments, with the small bowel being exclusively involved in up to 30% of all CD cases. Despite the widespread use of CE, several questions concerning the utility of this technique remain unanswered. The lack of commonly agreed diagnostic criteria for defining CD lesions with the aid of CE may have had an influence on the variation in diagnostic results for CE reported in the literature. The utility of CE in monitoring CD and in guiding therapy has also been proposed. Furthermore, CE could be a useful second-line technique for patients with an established diagnosis of CD and unexplained symptoms. Finally, as no threshold for CD diagnosis has been agreed upon, a severity scale of mucosal disease activity has not been universally followed. None of the available activity indexes based on CE findings has been independently validated. This article discusses several cutting-edge aspects of the usefulness of CE in CD 10 years after its introduction as a sensible method to study the small intestine.
Small bowel video capsule endoscopy in Crohn’s disease: What have we learned in the last ten years?
Lucendo, Alfredo J; Guagnozzi, Danila
2011-01-01
Since its introduction in 2001, capsule endoscopy (CE) has become the most important advance in the study of small bowel disease, including Crohn’s disease (CD). This technique has been demonstrated to be superior to all other current forms of radiological investigation in detecting mucosal abnormalities of small bowel nonstricturing CD. CE has proven to be extremely useful in diagnosing CD in patients with inconclusive findings from ileocolonoscopy and x-ray-based studies. Almost half of all patients with CD involving the ileum also present lesions in proximal intestinal segments, with the small bowel being exclusively involved in up to 30% of all CD cases. Despite the widespread use of CE, several questions concerning the utility of this technique remain unanswered. The lack of commonly agreed diagnostic criteria for defining CD lesions with the aid of CE may have had an influence on the variation in diagnostic results for CE reported in the literature. The utility of CE in monitoring CD and in guiding therapy has also been proposed. Furthermore, CE could be a useful second-line technique for patients with an established diagnosis of CD and unexplained symptoms. Finally, as no threshold for CD diagnosis has been agreed upon, a severity scale of mucosal disease activity has not been universally followed. None of the available activity indexes based on CE findings has been independently validated. This article discusses several cutting-edge aspects of the usefulness of CE in CD 10 years after its introduction as a sensible method to study the small intestine. PMID:21403813
Keeratichananont, Suriya; Sobhonslidsuk, Abhasnee; Kitiyakara, Taya; Achalanan, Narin; Soonthornpun, Supamai
2010-08-01
Simethicone improves endoscopic visibility and diagnostic accuracy during colonoscopy and capsule endoscopy. Nevertheless, there have been limited data on its usefulness in esophagogastroduodenoscopy (EGD). To evaluate the effectiveness of simethicone on enhancing endoscopic visibility in patients undergoing EGD. 121 patients were randomized to take 2 ml ofeither liquid simethicone or placebo in 60 ml of water at 15-30 minutes before EGD. The severity scores of foam and bubbles at the esophagus, stomach and duodenum were compared. Simethicone improved endoscopic visibility by diminishing mean cumulative (6.83 +/- 2.4 vs. 11.05 +/- 2.6, p < 0.001) and local scores offoam and bubbles at all areas, and decreased the number and timing ofadjunctive simethicone washing (17.5% vs. 74.1%, p < 0.001 and 0 vs. 19 seconds, p < 0.001). Simethicone increased endoscopist and patient satisfaction significantly without having adverse effects. Using simethicone before EGD enhances endoscopic visibility, reduces adjunctive simethicone washing and increases endoscopist and patient satisfaction.
Primary intestinal lymphangiectasia with generalized warts.
Lee, Soon Jae; Song, Hyun Joo; Boo, Sun-Jin; Na, Soo-Young; Kim, Heung Up; Hyun, Chang Lim
2015-07-21
Primary intestinal lymphangiectasia (PIL) is a rare protein-losing enteropathy with lymphatic leakage into the small intestine. Dilated lymphatics in the small intestinal wall and mesentery are observed in this disease. Laboratory tests of PIL patients revealed hypoalbuminemia, lymphocytopenia, hypogammaglobulinemia and increased stool α-1 antitrypsin clearance. Cell-mediated immunodeficiency is also present in PIL patients because of loss of lymphocytes. As a result, the patients are vulnerable to chronic viral infection and lymphoma. However, cases of PIL with chronic viral infection, such as human papilloma virus-induced warts, are rarely reported. We report a rare case of PIL with generalized warts in a 36-year-old male patient. PIL was diagnosed by capsule endoscopy and colonoscopic biopsy with histological tissue confirmation. Generalized warts were observed on the head, chest, abdomen, back, anus, and upper and lower extremities, including the hands and feet of the patient.
Primary intestinal lymphangiectasia with generalized warts
Lee, Soon Jae; Song, Hyun Joo; Boo, Sun-Jin; Na, Soo-Young; Kim, Heung Up; Hyun, Chang Lim
2015-01-01
Primary intestinal lymphangiectasia (PIL) is a rare protein-losing enteropathy with lymphatic leakage into the small intestine. Dilated lymphatics in the small intestinal wall and mesentery are observed in this disease. Laboratory tests of PIL patients revealed hypoalbuminemia, lymphocytopenia, hypogammaglobulinemia and increased stool α-1 antitrypsin clearance. Cell-mediated immunodeficiency is also present in PIL patients because of loss of lymphocytes. As a result, the patients are vulnerable to chronic viral infection and lymphoma. However, cases of PIL with chronic viral infection, such as human papilloma virus-induced warts, are rarely reported. We report a rare case of PIL with generalized warts in a 36-year-old male patient. PIL was diagnosed by capsule endoscopy and colonoscopic biopsy with histological tissue confirmation. Generalized warts were observed on the head, chest, abdomen, back, anus, and upper and lower extremities, including the hands and feet of the patient. PMID:26217101
Bass, Lee M; Kim, Stanley; Superina, Riccardo; Mohammad, Saeed
2017-02-01
Portal hypertension secondary to portal vein obstruction following liver transplant occurs in 5%-10% of children. Jejunal varices are uncommon in this group. We present a case series of children with significant GI blood loss, negative upper endoscopy, and jejunal varices detected by CE. Case series of patients who had CE for chronic GI blood loss following liver transplantation. Three patients who had their initial transplants at a median age of 7 months were identified at our institution presenting at a median age of 8 years (range 7-16 years) with a median Hgb of 2.8 g/dL (range 1.8-6.8 g/dL). Upper endoscopy was negative for significant esophageal varices, gastric varices, and bleeding portal gastropathy in all three children. All three patients had significant jejunal varices noted on CE in mid-jejunum. Jejunal varices were described as large prominent bluish vessels underneath visualized mucosa, one with evidence of recent bleeding. The results led to venoplasty of the portal vein in two patients and a decompressive shunt in one patient with resolution of GI bleed and anemia. CE is useful to diagnose intestinal varices in children with portal hypertension and GI bleeding following liver transplant. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Impact of demographic and clinical parameters on video capsule transit time.
Niv, Eva; Pinchasovich, Hadassa; Yanai, Henit
2016-10-01
Small bowel (SB) capsule endoscopy (CE) studies provide data on both gastric and SB transit times (GTT and SBTT, respectively). This study aimed to evaluate the influence of demographic and clinical parameters on the GTT and SBTT. Transit times for two generations of capsules (Pillcam SB2 and SB3) were also compared. Consecutive adult patients undergoing CE were included. GTT, SBTT, and cecum arrival rates were calculated and correlated to demographics and clinical characteristics. A total of 332 CE studies were analyzed. Neither GTT nor SBTT were impacted by age or sex. SBTT was prolonged in newly diagnosed Crohn's disease (CD) patients compared with all other patients (303.1±90.3 vs. 243.6±83.6 min, P=0.02 for SB2, 267.8±63 vs. 228.6±72.3, P=0.01 for SB3, respectively). Moreover, CD patients had higher incomplete study rates compared with patients with all other diagnoses (29.4 vs. 7.3%, respectively, P=0.0116) in the SB2 subgroup. Higher cecum arrival rates were achieved by the SB3 capsule compared with SB2 (97 vs. 91%, P=0.04). Patients with prolonged gastric time or patients with incomplete studies had similar demographic and clinical characteristics as others. Age and sex apparently do not influence intestinal kinetics. Newly diagnosed CD patients have relatively prolonged SBTTs. Demographic and clinical parameters cannot predict prolonged GTT or cecum nonarrival.
A Platform for Gastric Cancer Screening in Low- and Middle-Income Countries
Caprara, Robert; Obstein, Keith L.; Scozzarro, Gabriel; Natali, Christian Di; Beccani, Marco; Morgan, Douglas R.; Valdastri, Pietro
2015-01-01
Gastric cancer is the second leading cause of cancer death worldwide and screening programs have had a significant impact on reducing mortality. The majority of cases occur in low- and middle-income countries (LMIC), where endoscopy resources are traditionally limited. In this paper, we introduce a platform designed to enable inexpensive gastric screening to take place in remote areas of LMIC. The system consists of a swallowable endoscopic capsule connected to an external water distribution system by a multi-channel soft tether. Pressurized water is ejected from the capsule to orient the view of the endoscopic camera. After completion of a cancer screening procedure, the outer shell of the capsule and the soft tether can be disposed, while the endoscopic camera is reclaimed without needing further reprocessing. The capsule, measuring 12 mm in diameter and 28 mm in length, is able to visualize the inside of the gastric cavity by combining waterjet actuation and the adjustment of the tether length. Experimental assessment was accomplished through a set of bench trials, ex vivo analysis, and in vivo feasibility validation. During the ex vivo trials, the platform was able to visualize the main landmarks that are typically observed during a gastric cancer screening procedure in less than 8 minutes. Given the compact footprint, the minimal cost of the disposable parts, and the possibility of running on relatively available and inexpensive resources, the proposed platform can potentially widen gastric cancer screening programs in LMIC. PMID:25561586
Bayesian-based localization of wireless capsule endoscope using received signal strength.
Nadimi, Esmaeil S; Blanes-Vidal, Victoria; Tarokh, Vahid; Johansen, Per Michael
2014-01-01
In wireless body area sensor networking (WBASN) applications such as gastrointestinal (GI) tract monitoring using wireless video capsule endoscopy (WCE), the performance of out-of-body wireless link propagating through different body media (i.e. blood, fat, muscle and bone) is still under investigation. Most of the localization algorithms are vulnerable to the variations of path-loss coefficient resulting in unreliable location estimation. In this paper, we propose a novel robust probabilistic Bayesian-based approach using received-signal-strength (RSS) measurements that accounts for Rayleigh fading, variable path-loss exponent and uncertainty in location information received from the neighboring nodes and anchors. The results of this study showed that the localization root mean square error of our Bayesian-based method was 1.6 mm which was very close to the optimum Cramer-Rao lower bound (CRLB) and significantly smaller than that of other existing localization approaches (i.e. classical MDS (64.2mm), dwMDS (32.2mm), MLE (36.3mm) and POCS (2.3mm)).
NASA Astrophysics Data System (ADS)
Dong, Jing; Gora, Michalina J.; Beaulieu-Ouellet, Emilie; Queneherve, Lucille H.; Grant, Catriona N.; Rosenberg, Mireille; Nishioka, Norman S.; Fasano, Alessio; Tearney, Guillermo J.
2017-02-01
Celiac disease (CD) affects around 1% of the global population and can cause serious long-term symptoms including malnutrition, fatigue, and diarrhea, amongst others. Despite this, it is often left undiagnosed. Currently, a tissue diagnosis of CD is made by random endoscopic biopsy of the duodenum to confirm the existence of microscopic morphologic alterations in the intestinal mucosa. However, duodenal endoscopic biopsy is problematic because the morphological changes can be focal and endoscopic biopsy is plagued by sampling error. Additionally, tissue artifacts can also an issue because cuts in the transverse plane can make duodenal villi appear artifactually shortened and can bias the assessment of intraepithelial inflammation. Moreover, endoscopic biopsy is costly and poorly tolerated as the patient needs to be sedated to perform the procedure. Our lab has previously developed technology termed tethered capsule OCT endomicroscopy (TCE) to overcome these diagnostic limitations of endoscopy. TCE involves swallowing an optomechanically-engineered pill that generates 3D images of the GI tract as it traverses the lumen of the organ via peristalsis, assisted by gravity. In several patients we have demonstrated TCE imaging of duodenal villi, however the current TCE device design is not optimal for CD diagnosis as the villi compress when in contact with the smooth capsule's wall. In this work, we present methods for structuring the outer surface of the capsule to improve the visualization of the villi height and crypt depth. Preliminary results in humans suggest that new TCE capsule enables better visualization of villous architecture, making it possibly to comprehensively scan the entire duodenum to obtain a more accurate tissue diagnosis of CD.
Leighton, Jonathan A; Helper, Debra J; Gralnek, Ian M; Dotan, Iris; Fernandez-Urien, Ignacio; Lahat, Adi; Malik, Pramod; Mullin, Gerard E; Rosa, Bruno
2017-01-01
Crohn's disease (CD) is typically diagnosed with ileocolonoscopy (IC); however, when inflammation is localized solely in the small bowel, visualization of the entire small-bowel mucosa can be challenging. The aim of this study was to compare the diagnostic yield of a pan-enteric video capsule endoscope (small-bowel colon [SBC] capsule) versus IC in patients with active CD. This was a prospective, multicenter study. Patients with known active CD and proven bowel luminal patency underwent a standardized colon cleansing protocol followed by ingestion of the capsule. After passage of the capsule, IC was performed and recorded. Lesions indicative of active CD were assessed. One hundred fourteen subjects were screened; 66 subjects completed both endoscopic procedures. The per-subject diagnostic yield rate for active CD lesions was 83.3% for SBC and 69.7% for IC (yield difference, 13.6%; 95% confidence interval [CI], 2.6%-24.7%); 65% of subjects had active CD lesions identified by both modalities. Of the 12 subjects who were positive for active CD by SBC only, 5 subjects were found to have active CD lesions in the terminal ileum. Three subjects were positive for active CD by IC only. Three hundred fifty-five classifying bowel segments were analyzed; the per-segment diagnostic yield rate was 40.6% for SBC and 32.7% for IC (yield difference 7.9%; 95% CI, 3.3%-12.4%). This preliminary study shows that the diagnostic yields for SBC might be higher than IC; however, the magnitude of difference between the two is difficult to estimate. Further study is needed to confirm these findings. Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Role of capsule endoscopy in suspected celiac disease: A European multi-centre study
Luján-Sanchis, Marisol; Pérez-Cuadrado-Robles, Enrique; García-Lledó, Javier; Juanmartiñena Fernández, José-Francisco; Elli, Luca; Jiménez-García, Victoria-Alejandra; Egea-Valenzuela, Juan; Valle-Muñoz, Julio; Carretero-Ribón, Cristina; Fernández-Urién-Sainz, Ignacio; López-Higueras, Antonio; Alonso-Lázaro, Noelia; Sanjuan-Acosta, Mileidis; Sánchez-Ceballos, Francisco; Rosa, Bruno; González-Vázquez, Santiago; Branchi, Federica; Ruano-Díaz, Lucía; Prieto-de-Frías, César; Pons-Beltrán, Vicente; Borque-Barrera, Pilar; González-Suárez, Begoña; Xavier, Sofía; Argüelles-Arias, Federico; Herrerías-Gutiérrez, Juan-Manuel; Pérez-Cuadrado-Martínez, Enrique; Sempere-García-Argüelles, Javier
2017-01-01
AIM To analyze the diagnostic yield (DY), therapeutic impact (TI) and safety of capsule endoscopy (CE). METHODS This is a multi-centre, observational, analytical, retrospective study. A total of 163 patients with suspicion of celiac disease (CD) (mean age = 46.4 ± 17.3 years, 68.1% women) who underwent CE from 2003 to 2015 were included. Patients were divided into four groups: seronegative CD with atrophy (Group-I, n = 19), seropositive CD without atrophy (Group-II, n = 39), contraindication to gastroscopy (Group-III, n = 6), seronegative CD without atrophy, but with a compatible context (Group-IV, n = 99). DY, TI and the safety of CE were analysed. RESULTS The overall DY was 54% and the final diagnosis was villous atrophy (n = 65, 39.9%), complicated CD (n = 12, 7.4%) and other enteropathies (n = 11, 6.8%; 8 Crohn’s). DY for groups I to IV was 73.7%, 69.2%, 50% and 44.4%, respectively. Atrophy was located in duodenum in 24 cases (36.9%), diffuse in 19 (29.2%), jejunal in 11 (16.9%), and patchy in 10 cases (15.4%). Factors associated with a greater DY were positive serology (68.3% vs 49.2%, P = 0.034) and older age (P = 0.008). On the other hand, neither sex nor clinical presentation, family background, positive histology or HLA status were associated with DY. CE results changed the therapeutic approach in 71.8% of the cases. Atrophy was associated with a greater TI (92.3% vs 45.3%, P < 0.001) and 81.9% of the patients responded to diet. There was one case of capsule retention (0.6%). Agreement between CE findings and subsequent histology was 100% for diagnosing normal/other conditions, 70% for suspected CD and 50% for complicated CD. CONCLUSION CE has a high DY in cases of suspicion of CD and it leads to changes in the clinical course of the disease. CE is safe procedure with a high degree of concordance with histology and it helps in the differential diagnosis of CD. PMID:28216978
Xavier, Sofia; Monteiro, Sara; Magalhães, Joana; Rosa, Bruno; Moreira, Maria João; Cotter, José
2018-03-01
To compare the findings and completion rate of PillCam® SB2 and SB3. This was a retrospective single-center study that included 357 consecutive small bowel capsule endoscopies (SBCE), 173 SB2 and 184 SB3. The data collected included age, gender, capsule type (PillCam® SB2 or SB3), quality of bowel preparation, completion of the examination, gastric and small bowel transit time, small bowel findings, findings in segments other than the small bowel and the detection of specific anatomical markers, such as the Z line and papilla. The mean age of the patients was 48 years and 66.9% were female. The two main indications were suspicion/staging of inflammatory bowel disease (IBD) and obscure gastrointestinal bleeding (OGIB) (43.7% and 40.3%, respectively). Endoscopic findings were reported in 76.2% of examinations and 53.5% were relevant findings. No significant differences were found between SB2 and SB3 with regard to completion rate (93.6% vs 96.2%, p = 0.27), overall endoscopic findings (73.4% vs 78.8%, p = 0.23), relevant findings (54.3% vs 52.7%, p = 0.76), first tertile findings (43.9% vs 48.9%, p = 0.35), extra-SB findings (23.7% vs 17.3%, p = 0.14), Z line and papilla detection rate (35.9% vs 35.7%, p = 0.97 and 27.1% vs 32.6%, p = 0.32, respectively). With regard to the patient subgroups with suspicion/staging of IBD, significant differences were found in relation to the detection of villous edema and the 3rd tertile findings, thus favoring SB3 (26.3% vs 43.8%, p = 0.02 and 47.4% vs 66.3%, p = 0.02, respectively). Mucosal atrophy was significantly more frequently diagnosed with the PillCam® SB3 in patients with anemia/OGIB (0% vs 8%, p = 0.03). Overall, PillCam® SB3 did not improve the diagnostic yield compared to SB2, although it improved the detection of villous atrophy and segmental edema.
Localization and Tracking of Implantable Biomedical Sensors
Umay, Ilknur; Fidan, Barış; Barshan, Billur
2017-01-01
Implantable sensor systems are effective tools for biomedical diagnosis, visualization and treatment of various health conditions, attracting the interest of researchers, as well as healthcare practitioners. These systems efficiently and conveniently provide essential data of the body part being diagnosed, such as gastrointestinal (temperature, pH, pressure) parameter values, blood glucose and pressure levels and electrocardiogram data. Such data are first transmitted from the implantable sensor units to an external receiver node or network and then to a central monitoring and control (computer) unit for analysis, diagnosis and/or treatment. Implantable sensor units are typically in the form of mobile microrobotic capsules or implanted stationary (body-fixed) units. In particular, capsule-based systems have attracted significant research interest recently, with a variety of applications, including endoscopy, microsurgery, drug delivery and biopsy. In such implantable sensor systems, one of the most challenging problems is the accurate localization and tracking of the microrobotic sensor unit (e.g., robotic capsule) inside the human body. This article presents a literature review of the existing localization and tracking techniques for robotic implantable sensor systems with their merits and limitations and possible solutions of the proposed localization methods. The article also provides a brief discussion on the connection and cooperation of such techniques with wearable biomedical sensor systems. PMID:28335384
Motion analysis for duplicate frame removal in wireless capsule endoscope
NASA Astrophysics Data System (ADS)
Lee, Hyun-Gyu; Choi, Min-Kook; Lee, Sang-Chul
2011-03-01
Wireless capsule endoscopy (WCE) has been intensively researched recently due to its convenience for diagnosis and extended detection coverage of some diseases. Typically, a full recording covering entire human digestive system requires about 8 to 12 hours for a patient carrying a capsule endoscope and a portable image receiver/recorder unit, which produces 120,000 image frames on average. In spite of the benefits of close examination, WCE based test has a barrier for quick diagnosis such that a trained diagnostician must examine a huge amount of images for close investigation, normally over 2 hours. The main purpose of our work is to present a novel machine vision approach to reduce diagnosis time by automatically detecting duplicated recordings caused by backward camera movement, typically containing redundant information, in small intestine. The developed technique could be integrated with a visualization tool which supports intelligent inspection method, such as automatic play speed control. Our experimental result shows high accuracy of the technique by detecting 989 duplicate image frames out of 10,000, equivalently to 9.9% data reduction, in a WCE video from a real human subject. With some selected parameters, we achieved the correct detection ratio of 92.85% and the false detection ratio of 13.57%.
NASA Astrophysics Data System (ADS)
Vuong, Barry; Yin, Biwei; Beaulieu-Ouellet, Emilie; Liang, Chia Pin; Beatty, Matthew; Singh, Kanwarpal; Dong, Jing; Grant, Catriona N.; Rosenberg, Mireille; Tearney, Guillermo J.
2017-02-01
Endoscopy, the current standard of care for the diagnosis of upper gastrointestinal (GI) diseases, is not ideal as a screening tool because it is costly, necessitates a team of medically trained personnel, and typically requires that the patient be sedated. Endoscopy is also a superficial macroscopic imaging modality and therefore is unable to provide detailed information on subsurface microscopic structure that is required to render a precise tissue diagnosis. We have overcome these limitations through the development of an optical coherence tomography tethered capsule endomicroscopy (OCT-TCE) imaging device. The OCT-TCE device has a pill-like form factor with an optically clear wall to allow the contained opto-mechanical components to scan the OCT beam along the circumference of the esophagus. Once swallowed, the OCT-TCE device traverses the esophagus naturally via peristalsis and multiple cross-sectional OCT images are obtained at 30-40 μm lateral resolution by 7 μm axial resolution. While this spatial resolution enables differentiation of squamous vs columnar mucosa, crucial microstructural features such as goblet cells ( 10 μm), which signify intestinal metaplasia in BE, and enlarged nuclei that are indicative of dysplasia cannot be resolved with the current OCT-TCE technology. In this work we demonstrate a novel design of a high lateral resolution OCT-TCE device with an extended depth of focus (EDOF). The EDOF is created by use of self-imaging wavefront division multiplexing that produces multiple focused modes at different depths into the sample. The overall size of the EDOF TCE is similar to that of the previous OCT-TCE device ( 11 mm by 26 mm) but with a lateral resolution of 8 μm over a depth range of 2 mm. Preliminary esophageal and intestinal imaging using these EDOF optics demonstrates an improvement in the ability to resolve tissue morphology including individual glands and cells. These results suggest that the use of EDOF optics may be a promising avenue for increasing the accuracy of OCT-TCE for the diagnosis of upper GI diseases.
Endo, Hiroki; Kato, Takayuki; Sakai, Eiji; Taniguchi, Leo; Arimoto, Jun; Kawamura, Harunobu; Higurashi, Takuma; Ohkubo, Hidenori; Nonaka, Takashi; Taguri, Masataka; Inamori, Masahiko; Yamanaka, Takeharu; Sakaguchi, Takashi; Hata, Yasuo; Nagase, Hajime; Nakajima, Atsushi
2017-02-01
Aspirin use is reportedly not to be associated with fecal immunochemical occult blood test (FIT) false-positive results for the detection of colorectal cancer. The need for additional small bowel exploration in FIT-positive, low-dose aspirin users with a negative colonoscopy is controversial. The aim of this study was to assess the ability of FIT to judge whether capsule endoscopy (CE) should be performed in low-dose aspirin users with negative colonoscopy and esophagogastroduodenoscopy findings by comparing FIT results with CE findings. A total of 264 consecutive low-dose aspirin users with negative colonoscopy and esophagogastroduodenoscopy who were scheduled to undergo CE at five hospitals in Japan were enrolled. Patients had been offered FIT prior to the CE. The association between the FIT results and the CE findings was then assessed. One hundred and fifty-seven patients were included in the final analysis. Eighty-four patients (53.5 %) had positive FIT results. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of positive FIT results for small bowel ulcers were 0.56, 0.47, 0.30, and 0.73, respectively. Furthermore, the NPV of positive FIT results for severe small bowel injury (Lewis score ≥790) was markedly high (0.90). When the analysis was performed only in low-dose aspirin users with anemia, the sensitivity of the positive FIT results was notably improved (0.72). Small bowel evaluation using CE is not recommended for FIT-negative, low-dose aspirin users. However, small bowel evaluation using CE should be considered in both FIT-positive and anemic low-dose aspirin users.
Outcome in obscure gastrointestinal bleeding after capsule endoscopy.
Cañas-Ventura, Alex; Márquez, Lucia; Bessa, Xavier; Dedeu, Josep Maria; Puigvehí, Marc; Delgado-Aros, Sílvia; Ibáñez, Ines Ana; Seoane, Agustin; Barranco, Luis; Bory, Felipe; Andreu, Montserrat; González-Suárez, Begoña
2013-11-16
To investigate the clinical impact of capsule endoscopy (CE) after an obscure gastrointestinal bleeding (OGIB) episode, focusing on diagnostic work-up, follow-up and predictive factors of rebleeding. Patients who were referred to Hospital del Mar (Barcelona, Spain) between 2007 and 2009 for OGIB who underwent a CE were retrospectively analyzed. Demographic data, current treatment with non-steroid anti-inflammtory drugs or anticoagulant drugs, hemoglobin levels, transfusion requirements, previous diagnostic tests for the bleeding episode, as well as CE findings (significant or non-significant), work-up and patient outcomes were analyzed from electronic charts. Variables were compared by χ (2) analysis and Student t test. Risk factors of rebleeding were assessed by Log-rank test, Kaplan-Meier curves and Cox regression model. There were 105 patients [45.7% women, median age of 72 years old (interquartile range 56-79)] and a median follow-up of 326 d (interquartile range 123-641) included in this study. The overall diagnostic yield of CE was 58.1% (55.2% and 63.2%, for patients with occult OGIB and overt OGIB, respectively). In 73 patients (69.5%), OGIB was resolved. Multivariate analysis showed that hemoglobin levels lower than 8 g/dL at diagnosis [hazard ratios (HR) = 2.7, 95%CI: 1.9-6.3], patients aged 70 years and above (HR = 2.1, 95%CI: 1.2-6.1) and significant findings in CE (HR = 2.4, 95%CI: 1.1-5.8) were independent predictors of rebleeding. One third of the patients presented with rebleeding after CE; risk factors were hemoglobin levels < 8 g/dL, age ≥ 70 years or the presence of significant lesions.
Xavier, Sofia; Cúrdia Gonçalves, Tiago; Dias de Castro, Francisca; Magalhães, Joana; Rosa, Bruno; Moreira, Maria João; Cotter, José
2018-04-01
Perianal Crohn's disease (CD) prevalence varies according to the disease location, being particularly frequent in patients with colonic involvement. We aimed to evaluate small bowel involvement and compare small bowel capsule endoscopy findings and inflammatory activity between patients with and without perianal disease. Retrospective single-center study including 71 patients - all patients with perianal CD (17 patients) who performed a small bowel capsule endoscopy were included, and non-perianal CD patients were randomly selected (54 patients). Clinical and analytical variables at diagnosis were reviewed. Statistical analysis was performed with SPSS v21.0 and a two-tailed p value <.05 was defined as indicating statistical significance. Patients had a median age of 30 ± 16 years with 52.1% females. Perianal disease was present in 23.9%. Patients with perianal disease had significantly more relevant findings (94.1% vs 66.6%, p = .03) and erosions (70.6% vs 42.6%, p = .04), however, no differences were found between the two groups regarding ulcer, villous edema and stenosis detection. Overall, patients with perianal disease had more frequently significant small bowel inflammatory activity, defined as a Lewis Score ≥135 (94.1% vs 64.8%, p = .03), and higher Lewis scores in the first and second tertiles (450 ± 1129 vs 0 ± 169, p = .02 and 675 ± 1941 vs 0 ± 478, p = .04, respectively). No differences were found between the two groups regarding third tertile inflammatory activity assessed with the Lewis Score. Patients with perianal CD have significantly higher inflammatory activity in the small bowel, particularly in proximal small bowel segments, when compared with patients without perianal disease.
Kotwal, Vikram S; Attar, Bashar M; Gupta, Saurabh; Agarwal, Rajender
2014-02-01
The ideal bowel preparation regime before small bowel video capsule endoscopy (VCE) is not known. We carried out a systematic review and meta-analysis to study the effect of purgatives, antifoaming agents, and prokinetics on the outcomes associated with VCE. We performed literature searches in MEDLINE and Cochrane Library and included randomized-controlled trials studying the effect of purgatives, antifoaming agents, and prokinetics in patients undergoing VCE. Our outcomes of interest were visualization quality, diagnostic yield, and completion rate. Meta-analyses were carried out using the RevMan software and heterogeneity was assessed using the I statistic. Fifteen studies fulfilled the inclusion criteria. As compared with no bowel preparation, bowel preparation with polyethylene glycol (PEG) led to adequate visualization in a significantly higher number of patients undergoing VCE [odds ratio (OR) 3.13; 95% confidence interval (CI) 1.70-5.75]. Both PEG and sodium phosphate significantly improved the diagnostic yield (OR 1.68; 95% CI 1.16-2.42 and OR 1.77; 95% CI 1.18-2.64, respectively) but did not affect the completion rate. All studies with simethicone showed significantly improved visualization quality with its use as compared with overnight fasting or purgatives alone. Prokinetics did not significantly improve the completion rate of VCE. On the basis of the data available, a combination of PEG and simethicone appears to be the best approach for small bowel preparation before VCE. However, large multicenter randomized-controlled trials are needed to validate this recommendation and to evaluate the ideal dose of PEG and timing of bowel preparation before VCE. Prokinetics administered before VCE do not improve the completion rate and should not be used.
Chen, Hong-Bin; Lian-Xiang, Peng; Yue, Huang; Chun, Huang; Shu-Ping, Xiao; Rong-Pang, Lin; Xiao-Zong, Wang; Xiao-Lin, Li
2017-10-01
The approach to small bowel preparation before capsule endoscopy (CE) is still suboptimal. One hundred eighty patients were randomly allocated to 3 groups. Patients in Group A took 250 mL 20% mannitol and 1 L 0.9% saline orally at 05:00 hours on the day of the procedure. In Group B the same preparation was taken at 20:00 on the day before, and at 05:00 on the day of CE; in addition, 20 mL oral simethicone was taken 30 minutes before CE. Group C was treated identically to Group B, except that the patients fasted for 3 days and took 3 g senna orally 3 times daily before CE. The length of bowel containing green luminal contents was assessed by ImageJ software and bowel cleanliness was evaluated by computed assessment of the cleansing score. Cleansing of the whole small bowel and the distal small bowel were significantly different between the 3 groups (χ = 22.470, P = .000; χ = 17.029, P = .000, respectively). There were also significant differences between the 3 groups in the length of small bowel and specifically the length of the distal small bowel containing green luminal contents (χ = 12.390, P = .000, χ = 15.141, P = .000, respectively), but not with regard to the proximal small bowel (χ = 0.678, P = .509). Three days fasting and oral senna, combined with 20% mannitol and simethicone, before CE, can reduce the effects of bile on the small bowel and improve small bowel cleansing, especially in the distal small intestine.
Konishi, Masae; Shibuya, Tomoyoshi; Mori, Hiroki; Kurashita, Erina; Takeda, Tsutomu; Nomura, Osamu; Fukuo, Yuka; Matsumoto, Kenshi; Sakamoto, Naoto; Osada, Taro; Nagahara, Akihito; Ogihara, Tatsuo; Watanabe, Sumio
2014-04-01
Capsule endoscopy (CE) is an established technique for the detection and diagnosis of obscure gastrointestinal bleeding (OGIB). Flexible spectral imaging color enhancement (FICE) is a software feature of RAPID 6.5. This study assessed the value of FICE for accurate identification of red lesions during CE. We randomly selected 10 patients who underwent CE for OGIB at Juntendo University. The CE images were read by five endoscopists. Small bowel videos, which were recorded by regular CE devices (PillCam SB2, Given Imaging), were evaluated on RAPID 6.5. We standardized the reading condition to a dual view, at a speed of 20 frames/s in manual mode. This interpreted FICE-CE images obtained at settings 1-3. Both conventional and FICE images were read at random. We defined a conventional image as standard and investigated the potential of FICE in detecting small intestinal lesions by the Steel-Dwass test. We considered that conventional images represented baseline (100). On this basis, detection rates for FICE images were as follows: FICE1 = 266.4 ± 33.1 (p < 0.0001); FICE2 = 255.4 ± 25.6 (p < 0.0001); and FICE3 = 117.0 ± 12.3 (p = 0.9447). Detection rates using FICE1 and FICE2 images were significantly higher than conventional CE images. FICE1 and FICE2 were more useful in detecting erosions than conventional CE (p < 0.0001) and FICE3 (p < 0.0001). FICE-CE has a high level of visibility by transparentizing bile or enhancing the color difference associated with reddish mucosa. We found that FICE-CE images were useful in the diagnosing of small intestinal lesions.
Riccioni, Maria Elena; Urgesi, Riccardo; Cianci, Rossella; Bizzotto, Alessandra; Galasso, Domenico; Costamagna, Guido
2012-01-01
Enteroscopy, defined as direct visualization of the small bowel with the use of a fiberoptic or capsule endoscopy, has progressed considerably over the past several years. The need for endoscopic access to improve diagnosis and treatment of small bowel disease has led to the development of novel technologies one of which is non-invasive, the video capsule, and a type of invasive technique, the device-assisted enteroscopy. In particular, the device-assisted enteroscopy consists then of three different types of instruments all able to allow, in skilled hands, to display partially or throughout its extension (if necessary) the small intestine. Newer devices, double balloon, single balloon and spiral endoscopy, are just entering clinical use. The aim of this article is to review recent advances in small bowel enteroscopy, focusing on indications, modifications to improve imaging and techniques, pitfalls, and clinical applications of the new instruments. With new technologies, the trials and tribulations of learning new endoscopic skills and determining their role in the diagnosis and treatment of small bowel disease come. Identification of small bowel lesions has dramatically improved. Studies are underway to determine the best strategy to apply new enteroscopy technologies for the diagnosis and management of small bowel disease, particularly obscure bleeding. Vascular malformations such as angiectasis and small bowel neoplasms as adenocarcinoma or gastrointestinal stromal tumors. Complete enteroscopy of the small bowel is now possible. However, because of the length of the small bowel, endoscopic examination and therapeutic maneuvers require significant skill, radiological assistance, the use of deep sedation with the assistance of the anesthetist. Prospective randomized studies are needed to guide diagnostic testing and therapy with these new endoscopic techniques. PMID:23189216
NASA Astrophysics Data System (ADS)
Mackiewicz, Michal W.; Fisher, Mark; Jamieson, Crawford
2008-03-01
Wireless Capsule Endoscopy (WCE) is a colour imaging technology that enables detailed examination of the interior of the gastrointestinal tract. A typical WCE examination takes ~ 8 hours and captures ~ 40,000 useful images. After the examination, the images are viewed as a video sequence, which generally takes a clinician over an hour to analyse. The manufacturers of the WCE provide certain automatic image analysis functions e.g. Given Imaging offers in their Rapid Reader software: The Suspected Blood Indicator (SBI), which is designed to report the location in the video of areas of active bleeding. However, this tool has been reported to have insufficient specificity and sensitivity. Therefore it does not free the specialist from reviewing the entire footage and was suggested only to be used as a fast screening tool. In this paper we propose a method of bleeding detection that uses in its first stage Hue-Saturation-Intensity colour histograms to track a moving background and bleeding colour distributions over time. Such an approach addresses the problem caused by drastic changes in blood colour distribution that occur when it is altered by gastrointestinal fluids and allow detection of other red lesions, which although are usually "less red" than fresh bleeding, they can still be detected when the difference between their colour distributions and the background is large enough. In the second stage of our method, we analyse all candidate blood frames, by extracting colour (HSI) and texture (LBP) features from the suspicious image regions (obtained in the first stage) and their neighbourhoods and classifying them using Support Vector Classifier into Bleeding, Lesion and Normal classes. We show that our algorithm compares favourably with the SBI on the test set of 84 full length videos.
Egea-Valenzuela, Juan; González Suárez, Begoña; Sierra Bernal, Cristian; Juanmartiñena Fernández, José Francisco; Luján-Sanchís, Marisol; San Juan Acosta, Mileidis; Martínez Andrés, Blanca; Pons Beltrán, Vicente; Sastre Lozano, Violeta; Carretero Ribón, Cristina; de Vera Almenar, Félix; Sánchez Cuenca, Joaquín; Alberca de Las Parras, Fernando; Rodríguez de Miguel, Cristina; Valle Muñoz, Julio; Férnandez-Urién Sainz, Ignacio; Torres González, Carolina; Borque Barrera, Pilar; Pérez-Cuadrado Robles, Enrique; Alonso Lázaro, Noelia; Martínez García, Pilar; Prieto de Frías, César; Carballo Álvarez, Fernando
2018-05-01
Capsule endoscopy (CE) is the first-line investigation in cases of suspected Crohn's disease (CD) of the small bowel, but the factors associated with a higher diagnostic yield remain unclear. Our aim is to develop and validate a scoring index to assess the risk of the patients in this setting on the basis of biomarkers. Data on fecal calprotectin, C-reactive protein, and other biomarkers from a population of 124 patients with suspected CD of the small bowel studied by CE and included in a PhD study were used to build a scoring index. This was first used on this population (internal validation process) and after that on a different set of patients from a multicenter study (external validation process). An index was designed in which every biomarker is assigned a score. Three risk groups have been established (low, intermediate, and high). In the internal validation analysis (124 individuals), patients had a 10, 46.5, and 81% probability of showing inflammatory lesions in CE in the low-risk, intermediate-risk, and high-risk groups, respectively. In the external validation analysis, including 410 patients from 12 Spanish hospitals, this probability was 15.8, 49.7, and 80.6% for the low-risk, intermediate-risk, and high-risk groups, respectively. Results from the internal validation process show that the scoring index is coherent, and results from the external validation process confirm its reliability. This index can be a useful tool for selecting patients before CE studies in cases of suspected CD of the small bowel.
Lahat, Adi; Kopylov, Uri; Amitai, Marianne M; Neuman, Sandra; Levhar, Nina; Yablecovitch, Doron; Avidan, Benjamin; Yanai, Henit; Dotan, Iris; Chowers, Yehuda; Weiss, Batya; Ben-Horin, Shomron; Eliakim, Rami
2016-01-01
Background Despite differences in the information obtained by capsule endoscopy (CE) and magnetic resonance enterography (MRE), one of these modalities is usually needed when evaluating disease activity. There are no data on patients’ preference that would help guide the choice between these two modalities in these instances. Aim To compare patients’ tolerance and preference to MRE versus CE. Patients and methods Patients with known small bowel Crohn’s disease (CD) in clinical remission (Crohn’s disease activity index [CDAI] <150) or with mild symptoms (CDAI <220) were prospectively recruited. All patients underwent MRE followed by CE. Patients were asked to fill out a questionnaire addressing specific points regarding inconvenience during the preparation for the procedures, the procedures, and postprocedures. Side effects and procedure preference were addressed. Questionnaires were included for analysis only when more than 95% of the items were addressed. Results Fifty-six patients fulfilled inclusion criteria. Pre-exam discomfort, during-exam discomfort, nausea, vomiting, bloating, and abdominal pain were all significantly more prominent in MRE as compared to CE (P<0.0001, P<0.0001, P<0.0001, P=0.009, P=0.0002, P<0.0001, respectively). MRE was perceived as a more difficult procedure (P<0.0001). Furthermore, MRE was associated with a specific adverse event – claustrophobia. Seventy-eight percent of patients (44 patients) preferred to repeat CE as compared to 22% (P<0.0001) who preferred MRE. Conclusion CE was better tolerated by CD patients compared to MRE and was preferred by 78% of patients. The superior tolerability of CE should be considered along with the diagnostic features, and more data sought when choosing between these two modalities for CD patients for long-term follow-up. PMID:27354774
Kopylov, Uri; Klang, Eyal; Yablecovitch, Doron; Lahat, Adi; Avidan, Benjamin; Neuman, Sandra; Levhar, Nina; Greener, Tomer; Rozendorn, Noa; Beytelman, Arkadi; Yanai, Henit; Dotan, Iris; Chowers, Yehuda; Weiss, Batya; Ben-Horin, Shomron; Amitai, Marianne M.; Eliakim, Rami
2016-01-01
Background: Video capsule endoscopy (VCE) and magnetic resonance enterography (MRE) are the prime modalities for the evaluation of small bowel (SB) Crohn’s disease (CD). Mucosal inflammation on VCE is quantified using the Lewis score (LS). Diffusion-weighted (DW) magnetic resonance imaging (MRI) allows for accurate assessment of SB inflammation without administration of intravenous contrast material. The Magnetic Resonance Index of Activity (MaRiA) and the Clermont index are quantitative activity indices validated for contrast-enhanced MRE and DW-MRE, respectively. The aim of this study was to compare the quantification of distal SB inflammation by VCE and MR-related activity indices. Methods: Patients with known quiescent SB CD were prospectively recruited and underwent MRE and VCE. LS, MaRIA and Clermont scores were calculated for the distal SB. Results: Both MRI-based indices significantly correlated with the LS and the Clermont index (r = 0.50, p = 0.001 and r = 0.53, p = 0.001, respectively). Both MaRIA and Clermont scores were significantly lower in patients with mucosal healing (LS < 135). The area under the curve (AUC) with both MR scores was moderate for prediction of any mucosal inflammation (LS ⩾ 135) and excellent for prediction of moderate-to-severe inflammation (LS ⩾ 790) (0.71 and 0.74 versus 0.93 and 0.91 for MaRIA and Clermont score, respectively). Conclusions: Modest correlation between VCE- and MRE-based quantitative indices of inflammation in patients with quiescent SB CD was observed. Between-modality correlation was higher in patients with endoscopically severe disease. DW-MRE gauged by Clermont score was at least as accurate as contrast-enhanced MRE for quantification of SB inflammation. PMID:27582877
De Palma, G D; Salvatori, F; Masone, S; Simeoli, I; Rega, M; Celiento, M; Persico, G
2007-09-01
A 58-year old man was admitted to the hospital because of melena. He had a 1-year history of mechanical aortic valve replacement and coronary stent placement because of myocardial infarction and he was taking warfarin and clopidogrel. Esophagogastroduodenoscopy and colonoscopy were negative for bleeding. Capsule endoscopy showed bleeding diffuse angiodysplasia of the small bowel. The patient was treated with octreotide 20 mg, at monthly interval. After 25 months there had been no recurrence of gastrointestinal bleeding. The case suggests that mechanical valve replacement may not prevent gastrointestinal bleeding in Heyde syndrome and that octreotide treatment should be considered in these cases.
Novel disposable transnasal endoscopy for assessment of esophageal motor function.
Lim, Chul-Hyun; Choi, Myung-Gyu; Baeg, Myong-Ki; Moon, Sung Jin; Kim, Jin Su; Cho, Yu Kyung; Park, Jae Myung; Lee, In Seok; Kim, Sang Woo; Choi, Kyu Yong
2014-01-01
A novel disposable transnasal endoscopy (DTE) with a portable system has been developed to provide unsedated esophagoscopy by modifying capsule endoscopy. The aim of this study was to assess the feasibility of DTE to evaluate esophageal motor function. Patients with or suspected esophageal motility disorders and healthy volunteers were enrolled. Participants underwent esophageal high-resolution manometry and DTE in random order on different days. Motility was observed with DTE at 1, 8, and 16 cm above the gastroesophageal junction. Twenty healthy volunteers and 20 symptomatic subjects participated (8 achalasia, 5 scleroderma, 3 diffuse esophageal spasm, 1 hypertensive peristalsis, 1 peristaltic dysfunction, and 22 normal esophageal function). The normal findings on DTE were as follows. As the subject swallowed water, swallow-induced relaxation with elevation of the lower esophageal sphincter caused the endoscope to cross the Z-line into the gastric lumen. After the passage of water and air, complete closure of the lower esophageal sphincter occurred, with the return of the endoscope to its previous position. During the resting stage of the esophageal body, an air bubble could be seen in the center of the radially wrinkled and occluded lumen. The endoscopic diagnosis was in agreement with the clinical diagnosis in all but 2. Most of the participants reported acceptable discomfort during DTE and 62.5% of the subjects preferred DTE to manometry. DTE can accurately characterize normal esophageal motor function, allowing the diagnosis of esophageal motility disorders. DTE has potential widespread applications, especially in outpatient clinics.
Wide-field phase imaging for the endoscopic detection of dysplasia and early-stage esophageal cancer
NASA Astrophysics Data System (ADS)
Fitzpatrick, C. R. M.; Gordon, G. S. D.; Sawyer, T. W.; Wilkinson, T. D.; Bohndiek, S. E.
2018-02-01
Esophageal cancer has a 5-year survival rate below 20%, but can be curatively resected if it is detected early. At present, poor contrast for early lesions in white light imaging leads to a high miss rate in standard-of- care endoscopic surveillance. Early lesions in the esophagus, referred to as dysplasia, are characterized by an abundance of abnormal cells with enlarged nuclei. This tissue has a different refractive index profile to healthy tissue, which results in different light scattering properties and provides a source of endogenous contrast that can be exploited for advanced endoscopic imaging. For example, point measurements of such contrast can be made with scattering spectroscopy, while optical coherence tomography generates volumetric data. However, both require specialist interpretation for diagnostic decision making. We propose combining wide-field phase imaging with existing white light endoscopy in order to provide enhanced contrast for dysplasia and early-stage cancer in an image format that is familiar to endoscopists. Wide-field phase imaging in endoscopy can be achieved using coherent illumination combined with phase retrieval algorithms. Here, we present the design and simulation of a benchtop phase imaging system that is compatible with capsule endoscopy. We have undertaken preliminary optical modelling of the phase imaging setup, including aberration correction simulations and an investigation into distinguishing between different tissue phantom scattering coefficients. As our approach is based on phase retrieval rather than interferometry, it is feasible to realize a device with low-cost components for future clinical implementation.
Bond, Ashley; Burkitt, Michael D; Cox, Trevor; Smart, Howard L; Probert, Chris; Haslam, Neil; Sarkar, Sanchoy
2017-03-01
In the UK, the majority of diagnostic upper gastrointestinal (UGI) endoscopies are a result of direct-to-test referral from the primary care physician. The diagnostic yield of these tests is relatively low, and the burden high on endoscopy services. Dual-focus magnification, high-definition endoscopy is expected to improve detection and classification of UGI mucosal lesions and also help minimize biopsies by allowing better targeting. This is a retrospective study of patients attending for direct-to-test UGI endoscopy from January 2015 to June 2015. The primary outcome of interest was the identification of significant pathology. Detection of significant pathology was modelled using logistic regression. 500 procedures were included. The mean age of patients was 61.5 (±15.6) years; 60.8% of patients were female. Ninety-four gastroscopies were performed using dual-focus magnification high-definition endoscopy. Increasing age, male gender, type of endoscope, and type of operator were all identified as significant factors influencing the odds of detecting significant mucosal pathology. Use of dual-focus magnification, high-definition endoscopy was associated with an odds ratio of 1.87 (95%CI 1.11-3.12) favouring the detection of significant pathology. Subsequent analysis suggested that the increased detection of pathology during dual-focus magnification, high-definition endoscopy also influenced patient follow-up and led to a 3.0 fold (p=0.04) increase in the proportion of patients entered into an UGI endoscopic surveillance program. Dual-focus magnification, high-definition endoscopy improved the diagnostic yield for significant mucosal pathology in patients referred for direct-to-test endoscopy. If this finding is recapitulated elsewhere it will have substantial impact on the provision of UGI endoscopic services.
Peloquin, Joanna M; Seraj, Siamak M; King, Lindsay Y; Campbell, Emily J; Ananthakrishnan, Ashwin N; Richter, James M
2016-06-01
Gastrointestinal bleeding is a well-known risk of systemic anticoagulation. However, bleeding in the setting of supratherapeutic anticoagulation may have a milder natural history than unprovoked bleeding. It is a common clinical gestalt that endoscopy is common, but bleeding source identification or intervention is uncommon, yet few data exist to inform this clinical impression. Consequently, we sought to examine our institutional experience with gastrointestinal bleeding in the setting of supratherapeutic international normalized ratio (INR) with the aim of identifying predictors of endoscopically identifiable lesions, interventions, and outcomes. A retrospective review was conducted at a tertiary referral academic medical center to identify patients presenting with gastrointestinal bleeding in the setting of warfarin and a supratherapeutic INR (>3.5) who underwent an endoscopic procedure. Relevant clinical covariates, endoscopic findings, need for intervention, and outcomes were collected by review of the medical record. Logistic regression adjusting for potential confounders identified predictors of endoscopically significant lesions as well as intervention and outcomes. A total of 134 patients with INR 3.5 or greater (mean 5.5, range 3.5-17.1) presented with symptoms of gastrointestinal bleeding, most commonly as melena or symptomatic anemia. Antiplatelet agents were used by 54% of patients, and 60% of patients were on concomitant acid suppression on admission. Procedures included esophagogastroduodenoscopy (upper endoscopy; EGD) (n = 128), colonoscopy (n = 73), and video capsule endoscopy (n = 32). Active bleeding at first EGD or colonoscopy was found in only 19 patients (18%), with endoscopic intervention in only 26 patients (25%). At a critical threshold of INR 7.5 at presentation, the likelihood of finding an endoscopically significant lesion fell to <20%. On multivariate logistic regression, concomitant antiplatelet therapy (odds ratio [OR] 2.59; 95% confidence interval [CI], 1.13-5.94), timing of EGD within 12 hours of presentation (OR 3.71; 95% CI, 1.05-13.08), and INR level (OR 0.79; 95% CI, 0.64-0.98) were the only significant independent predictors of identifying a source of bleeding. A risk score incorporating these covariates performed modestly in identifying risk of significant finding on EGD (area under the curve 0.68). We found no association between identification of a significant lesion at EGD and future readmission for gastrointestinal bleeding. This study demonstrates that the relationship between INR elevation and identification of a bleeding source or endoscopic intervention at EGD are indeed antiparallel. Concomitant antiplatelet therapy increases the likelihood of bleeding source identification and intervention, as does EGD within 12 hours of presentation. However, regardless of source identification or endoscopic intervention, important clinical outcomes were unchanged, suggesting that decisions about endoscopy should be made on a case-by-case basis, particularly in patients with INR > 7.5. Future prospective studies on appropriate indications and timing of endoscopy in such patients are warranted. Copyright © 2016 Elsevier Inc. All rights reserved.
Mulder, Chris J J; Jacobs, Maarten A J M; Leicester, Roger J; Nageshwar Reddy, D; Shepherd, Libby E A; Axon, Anthony T; Waye, Jerome D
2013-07-01
A dedicated digestive disease endoscopy unit is structurally and functionally differentiating rapidly as a result of increasing diagnostic and therapeutic possibilities in the last 10-20 years. Publications with practical details are scarce, imposing a challenge in the construction of such a unit. The lack of authoritative information about endoscopy unit design means that architects produce their own design with or without consulting endoscopists working in such a unit. A working group of the World Endoscopy Organization discussed and outlined a practical approach fordesign and construction of a modern endoscopy unit. Designing the layout is extremely important, necessitating thoughtful planning to provide comfort to the endoscopy staff and patients, and efficient data archiving and transmission during endoscopic services. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.
An unusual presentation of a chronic ingested foreign body in an adult.
Kropf, Jesse A H; Jeanmonod, Rebecca; Yen, David M
2013-01-01
Sore throat is a common complaint for patients presenting to the emergency department (ED). Although most are caused by viral and bacterial sources, an ingested foreign body must be considered in the right patient population. Retained foreign bodies occur in both children and adults. In children, the objects are usually non-food items, whereas adults are more likely to have impacted food boluses. Typically, patients present acutely, and chronic foreign bodies are rare, especially in adults. We use an unusual presentation of a retained foreign body in a previously undiagnosed Zenker diverticulum to review ingested foreign bodies and Zenker diverticuli. We report the case of an 82-year-old woman who presented to the ED with a chief complaint of 12 h of worsening pharyngitis and odynophagia. She reported she had a capsule endoscopy performed approximately 4 months earlier during which the device had malfunctioned and no images were transmitted from beyond the esophagus. A soft tissue film of the neck showed the endoscopic capsule retained at the level of the clavicles. Esophagogastroduodenoscopy demonstrated a previously undiagnosed Zenker diverticulum containing the endoscope capsule. This was subsequently removed with laryngoscopy. Complaints related to sore throat commonly have a simple explanation. Recurrent symptoms and a physical examination inconsistent with common explanations require the differential to be broadened and less common causes considered. Copyright © 2013 Elsevier Inc. All rights reserved.
Present status of endoscopy, therapeutic endoscopy and the endoscopy training system in Indonesia.
Makmun, Dadang
2014-04-01
Recently, Indonesia was ranked as the fourth most populous country in the world. Based on 2012 data, 85000 general practitioners and 25000 specialists are in service around the country. Gastrointestinal (GI) disease remains the most common finding in daily practise, in both outpatient and inpatient settings, and ranks fifth in causing mortality in Indonesia. Management of patients with GI disease involves all health-care levels with the main portion in primary health care. Some are managed by specialists in secondary health care or are referred to tertiary health care. GI endoscopy is one of the main diagnostic and therapeutic modalities in the management of GI disease. Development of GI endoscopy in Indonesia started before World War II and, today, many GI endoscopy procedures are conducted in Indonesia, both diagnostic and therapeutic. Based on August 2013 data, there are 515 GI endoscopists in Indonesia. Most GI endoscopists are competent in carrying out basic endoscopy procedures, whereas only a few carry out advanced endoscopy procedures, including therapeutic endoscopy. Recently, the GI endoscopy training system in Indonesia consists of basic GI endoscopy training of 3-6 months held at 10 GI endoscopy training centers. GI endoscopy training is also eligible as part of a fellowship program of consultant gastroenterologists held at six accredited fellowship centers in Indonesia. Indonesian Society for Digestive Endoscopy in collaboration with GI endoscopy training centers in Indonesia and overseas has been working to increase quality and number of GI endoscopists, covering both basic and advanced GI endoscopy procedures. © 2014 The Author. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.
Nuzzo, Alexandre; Zappa, Magaly; Cazals-Hatem, Dominique; Bouhnik, Yoram
2016-09-01
Mesenteric panniculitis (MP) is mostly an associated sign of an intra-abdominal or systemic inflammatory primary disease. Nevertheless, etiological and differential diagnosis of idiopathic MP can be challenging when an associate primary cause is not in the foreground. We report here the case of an isolated small bowel Crohn's disease, long time considered as idiopathic MP. This patient presented to our department with a 10-year history of acute abdominal symptoms evolving with flare-up and remission. A diagnosis of idiopathic MP was made based on compatible CT-scan features along with normal laboratory tests and upper and lower bowel endoscopies. As symptoms recurred, a steroid course was proposed which dramatically improved his condition for years. Finally, an explorative laparoscopy was performed because of concern of malignancy when he returned to our unit with a steroid refractory flare-up and weight loss, along with MP nodes growing up to 10 mm. Crohn's disease was eventually diagnosed, based on histopathological middle-gut bowel resection and numerous granulomas in mesenteric nodes without necrosis. This case emphasizes the importance of excluding inflammatory intestinal lesions before making the diagnosis of idiopathic MP (fecal calprotectin, magnetic resonance enterography, wireless capsule endoscopy).
Gourgiotis, Stavros; Kotoulas, Dimitrios; Aloizos, Stavros; Kolovou, Aikaterini; Salemis, Nikolaos S; Kantounakis, Ioannis
2009-09-10
Gastrointestinal stromal tumours are rare mesenchymal neoplasms affecting the digestive tract or nearby structures within the abdomen. We present a case of a 66-year-old female patient who presented with obscure anemia due to gastrointestinal bleeding and underwent exploratory laparotomy during which a large gastrointestinal stromal tumour of the small intestine was discovered. Examining the preoperative results of video capsule endoscopy, computed tomography, and angiography and comparing them with the operative findings we discuss which of these investigations plays the most important role in the detection and localization of gastrointestinal stromal tumours. A sort review of the literature is also conducted on these rare mesenchymal tumours.
Gourgiotis, Stavros; Kotoulas, Dimitrios; Aloizos, Stavros; Kolovou, Aikaterini; Salemis, Nikolaos S; Kantounakis, Ioannis
2009-11-25
Gastrointestinal stromal tumours (GISTs) are rare mesenchymal neoplasms affecting the digestive tract or nearby structures within the abdomen. We present a case of a 66-year-old female patient who presented with obscure anemia due to gastrointestinal bleeding and underwent exploratory laparotomy during which a large GIST of the small intestine was discovered. Examining the preoperative results of video capsule endoscopy, computed tomography, and angiography and comparing them with the operative findings we discuss which of these investigations plays the most important role in the detection and localization of GIST. A sort review of the literature is also conducted on these rare mesenchymal tumours.
Mizukami, Kazuhiro; Murakami, Kazunari; Yamauchi, Mika; Matsunari, Osamu; Ogawa, Ryo; Nakagawa, Yoshifumi; Okimoto, Tadayoshi; Kodama, Masaaki; Fujioka, Toshio
2013-05-01
Non-steroidal anti-inflammatory drugs have the potential to injure the mucosa of the upper digestive tract and small bowel, whereas celecoxib (a selective cyclooxygenase-2 inhibitor) has less influence on the entire digestive tract mucosa. The present study was conducted to compare the extents of small bowel mucosal injury induced by celecoxib and loxoprofen (the most frequently used non-steroidal anti-inflammatory drugs in Japan). Ten healthy adult males were given celecoxib (200 mg/day, Group C) and loxoprofen (180 mg/day, Group L) in a cross-over design for 14 days, and the influence of each drug on small bowel mucosa was evaluated by comparing pre- and post-treatment capsule endoscopy findings. We measured the percentage of patients with small bowel mucosal injury following administration of these drugs as primary endpoint. Additionally, mean number of small bowel mucosal injuries per subject was analyzed as secondary endpoint. The percentage of subjects experiencing small bowel mucosal injury as primary endpoint was 10% in Group C and 70% in Group L after treatment. This magnitude of the difference of between Group C and Group L was statistically significant (P = 0.031). The number of small bowel mucosal injuries as secondary endpoint differed significantly between the two groups, and the influence of celecoxib on small bowel injury was less than that of loxoprofen. These results indicate that celecoxib has less influence on small bowel mucosa than loxoprofen and can be used safely. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.
Watanabe, Toshio; Takeuchi, Toshihisa; Handa, Osamu; Sakata, Yasuhisa; Tanigawa, Tetsuya; Shiba, Masatsugu; Naito, Yuji; Higuchi, Kazuhide; Fujimoto, Kazuma; Yoshikawa, Toshikazu; Arakawa, Tetsuo
2015-01-01
Low-dose aspirin (LDA) frequently causes small bowel injury. While some drugs have been reported to be effective in treating LDA-induced small intestinal damage, most studies did not exclude patients with mild damage thought to be clinically insignificant. We conducted a multicenter, randomized, double-blind, placebo-controlled trial to assess the efficacy of a high dose of rebamipide, a gastroprotective drug, for LDA-induced moderate-to-severe enteropathy. We enrolled patients who received 100 mg of enteric-coated aspirin daily for more than 3 months and were found to have more than 3 mucosal breaks (i.e., erosions or ulcers) in the small intestine by capsule endoscopy. Eligible patients were assigned to receive either rebamipide 300 mg (triple dose) 3 times daily or placebo for 8 weeks in a 2:1 ratio. Capsule endoscopy was then repeated. The primary endpoint was the change in the number of mucosal breaks from baseline to 8 weeks. Secondary endpoints included the complete healing of mucosal breaks at 8 weeks and the change in Lewis score (an endoscopic score assessing damage severity) from baseline to 8 weeks. The study was completed by 38 patients (rebamipide group: n = 25, placebo group: n = 13). After 8 weeks of treatment, rebamipide, but not placebo, significantly decreased the number of mucosal breaks (p = 0.046). While the difference was not significant (p = 0.13), the rate of complete mucosal break healing in the rebamipide group (32%, 8 of 25) tended to be higher than that in the placebo group (7.7%, 1 of 13). Rebamipide treatment significantly improved intestinal damage severity as assessed by the Lewis score (p = 0.02), whereas placebo did not. The triple dose of rebamipide was well tolerated. High-dose rebamipide is effective for the treatment of LDA-induced moderate-to-severe enteropathy. UMIN Clinical Trials Registry UMIN000003463.
Watanabe, Toshio; Takeuchi, Toshihisa; Handa, Osamu; Sakata, Yasuhisa; Tanigawa, Tetsuya; Shiba, Masatsugu; Naito, Yuji; Higuchi, Kazuhide; Fujimoto, Kazuma; Yoshikawa, Toshikazu; Arakawa, Tetsuo
2015-01-01
Background Low-dose aspirin (LDA) frequently causes small bowel injury. While some drugs have been reported to be effective in treating LDA-induced small intestinal damage, most studies did not exclude patients with mild damage thought to be clinically insignificant. Aim We conducted a multicenter, randomized, double-blind, placebo-controlled trial to assess the efficacy of a high dose of rebamipide, a gastroprotective drug, for LDA-induced moderate-to-severe enteropathy. Methods We enrolled patients who received 100 mg of enteric-coated aspirin daily for more than 3 months and were found to have more than 3 mucosal breaks (i.e., erosions or ulcers) in the small intestine by capsule endoscopy. Eligible patients were assigned to receive either rebamipide 300 mg (triple dose) 3 times daily or placebo for 8 weeks in a 2:1 ratio. Capsule endoscopy was then repeated. The primary endpoint was the change in the number of mucosal breaks from baseline to 8 weeks. Secondary endpoints included the complete healing of mucosal breaks at 8 weeks and the change in Lewis score (an endoscopic score assessing damage severity) from baseline to 8 weeks. Results The study was completed by 38 patients (rebamipide group: n = 25, placebo group: n = 13). After 8 weeks of treatment, rebamipide, but not placebo, significantly decreased the number of mucosal breaks (p = 0.046). While the difference was not significant (p = 0.13), the rate of complete mucosal break healing in the rebamipide group (32%, 8 of 25) tended to be higher than that in the placebo group (7.7%, 1 of 13). Rebamipide treatment significantly improved intestinal damage severity as assessed by the Lewis score (p = 0.02), whereas placebo did not. The triple dose of rebamipide was well tolerated. Conclusions High-dose rebamipide is effective for the treatment of LDA-induced moderate-to-severe enteropathy. Trial Registration UMIN Clinical Trials Registry UMIN000003463 PMID:25874951
Cloud, M L; Enas, N; Offen, W W
1992-09-01
To determine if 150 mg nizatidine twice daily or 300 mg nizatidine at bedtime are similarly effective and to compare each dose with placebo in healing benign gastric ulcers and relieving peptic ulcer symptoms. This study was a randomized, double-blind, placebo-controlled parallel comparison. The study was conducted at 74 gastroenterology and internal medicine clinics in the United States and Canada. Four hundred fifty-six patients with active benign gastric ulcer documented by endoscopy participated in the study. On the basis of a computer-generated randomization list, patients were assigned sequentially to receive either 150 mg nizatidine twice daily (n = 151), 300 mg nizatidine once daily at bedtime and identically appearing placebo capsules in the morning (n = 153), or placebo capsules twice daily (n = 152). Treatment lasted for 8 weeks unless healing was documented by endoscopy after 4 weeks. Antacid tablets (aluminum hydroxide, magnesium hydroxide, simethicone combination) were supplied for relief of symptoms. Both doses of nizatidine significantly improved healing rates at 8 weeks compared with placebo. Daytime and nighttime symptom severity was improved by both nizatidine regimens at end point (p less than 0.015 versus placebo, two-tailed test). Antacid use was similar for all groups in the end point analysis. Patient well-being was significantly better in patients treated with nizatidine than in patients in the placebo group ((p less than 0.04, two-tailed test). No clinically significant differences in the incidence of adverse clinical or laboratory events were noted. Nizatidine, 300 mg at bedtime and 150 mg twice daily, resulted in greater healing of benign gastric ulcers than placebo treatment after 8 weeks. Relief of the symptoms of gastric ulcer was significantly better in the patients receiving nizatidine treatment versus placebo treatment.
Addition of simethicone improves small bowel capsule endoscopy visualisation quality.
Krijbolder, M S; Grooteman, K V; Bogers, S K; de Jong, D J
2018-01-01
Small bowel capsule endoscopy (SBCE) is an important diagnostic tool for small-bowel diseases but its quality may be hampered by intraluminal gas. This study evaluated the added value of the anti-foaming agent, simethicone, to a bowel preparation with polyethylene glycol (PEG) on the quality of small bowel visualisation and its use in the Netherlands. This was a retrospective, single-blind, cohort study. Patients in the PEG group only received PEG prior to SBCE. Patients in the PEG-S group ingested additional simethicone. Two investigators assessed the quality of small-bowel visualisation using a four-point scale for 'intraluminal gas' and 'faecal contamination'. By means of a survey, the use of anti-foaming agents was assessed in a random sample of 16 Dutch hospitals performing SBCE. The quality of small bowel visualisation in the PEG group (n = 33) was significantly more limited by intraluminal gas when compared with the PEG-S group (n = 31): proximal segment 83.3% in PEG group vs. 18.5% in PEG-S group (p < 0.01), distal segment 66.7% vs. 18.5% respectively (p < 0.01). No difference was observed in the amount of faecal contamination (proximal segment 80.0% PEG vs. 59.3% PEG-S, p = 0.2; distal segment 90.0% PEG vs. 85.2% PEG-S, p = 0.7), mean small bowel transit times (4.0 PEG vs. 3.9 hours PEG-S, p = 0.7) and diagnostic yield (43.3% PEG vs. 22.2% PEG-S, p = 0.16). Frequency of anti-foaming agent use in the Netherlands was low (3/16, 18.8%). Simethicone is of added value to a PEG bowel preparation in improving the quality of visualisation of the small bowel by reducing intraluminal gas. At present, the use of anti-foaming agents in SBCE preparation is not standard practice in the Netherlands.
Chen, Hong-bin; Lian-xiang, Peng; Yue, Huang; Chun, Huang; Shu-ping, Xiao; Rong-pang, Lin; Xiao-zong, Wang; Xiao-lin, Li
2017-01-01
Abstract Background and Study Aims: The approach to small bowel preparation before capsule endoscopy (CE) is still suboptimal. Patients and Methods: One hundred eighty patients were randomly allocated to 3 groups. Patients in Group A took 250 mL 20% mannitol and 1 L 0.9% saline orally at 05:00 hours on the day of the procedure. In Group B the same preparation was taken at 20:00 on the day before, and at 05:00 on the day of CE; in addition, 20 mL oral simethicone was taken 30 minutes before CE. Group C was treated identically to Group B, except that the patients fasted for 3 days and took 3 g senna orally 3 times daily before CE. The length of bowel containing green luminal contents was assessed by ImageJ software and bowel cleanliness was evaluated by computed assessment of the cleansing score. Results: Cleansing of the whole small bowel and the distal small bowel were significantly different between the 3 groups (χ2 = 22.470, P = .000; χ2 = 17.029, P = .000, respectively). There were also significant differences between the 3 groups in the length of small bowel and specifically the length of the distal small bowel containing green luminal contents (χ2 = 12.390, P = .000, χ2 = 15.141, P = .000, respectively), but not with regard to the proximal small bowel (χ2 = 0.678, P = .509). Conclusions: Three days fasting and oral senna, combined with 20% mannitol and simethicone, before CE, can reduce the effects of bile on the small bowel and improve small bowel cleansing, especially in the distal small intestine. PMID:29069003
Penny, Hugo A; Mooney, Peter D; Burden, Mitchell; Patel, Nisha; Johnston, Alexander J; Wong, Simon H; Teare, Julian; Sanders, David S
2016-06-01
Celiac disease remains underdiagnosed at endoscopy. We aimed to assess the utility of I-Scan (virtual chromo-endoscopy) to improve sensitivity of endoscopy to detect markers of villous atrophy in this condition. Patients from 2 UK hospitals were studied in 3 groups. Group 1: standard high definition, white light endoscopy (WLE); Group 2: WLE plus I-Scan; Group 3: non-high definition control group. The presence of endoscopic markers was recorded. At least 4 duodenal biopsies were taken from all patients. Serology was performed concurrently and observations were compared with histology. 758 patients (62% female, mean age 52) were recruited (Group 1: 230; Group 2: 228; Group 3: 300). 135 (17.8%) new diagnoses of coeliac disease were made (21 Group 1; 24 Group 2; 89 Group 3). The sensitivity for detection of endoscopic markers of villous atrophy was significantly higher in both Group 1 (85.7%, p=0.0004) and Group 2 (75%, p=0.005) compared to non-high definition controls (41.6%). There was no significant difference between high definition only and I-Scan groups (p=0.47). In non-high definition endoscopy a missed diagnosis was associated with lesser degrees of villous atrophy (p=0.019) and low tTG titre (p=0.007). High definition endoscopy with or without I-Scan increases the detection of celiac disease during routine endoscopy. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Sylvester, Peter T.; Evans, John A.; Zipfel, Gregory J.; Chole, Richard A.; Uppaluri, Ravindra; Haughey, Bruce H.; Getz, Anne E.; Silverstein, Julie; Rich, Keith M.; Kim, Albert H.; Dacey, Ralph G.
2014-01-01
Purpose The clinical benefit of combined intraoperative magnetic resonance imaging (iMRI) and endoscopy for transsphenoidal pituitary adenoma resection has not been completely characterized. This study assessed the impact of microscopy, endoscopy, and/or iMRI on progression-free survival, extent of resection status (gross-, near-, and subtotal resection), and operative complications. Methods Retrospective analyses were performed on 446 transsphenoidal pituitary adenoma surgeries at a single institution between 1998 and 2012. Multivariate analyses were used to control for baseline characteristics, differences during extent of resection status, and progression-free survival analysis. Results Additional surgery was performed after iMRI in 56/156 cases (35.9 %), which led to increased extent of resection status in 15/156 cases (9.6 %). Multivariate ordinal logistic regression revealed no increase in extent of resection status following iMRI or endoscopy alone; however, combining these modalities increased extent of resection status (odds ratio 2.05, 95 % CI 1.21–3.46) compared to conventional transsphenoidal microsurgery. Multivariate Cox regression revealed that reduced extent of resection status shortened progression-free survival for near- versus gross-total resection [hazard ratio (HR) 2.87, 95 % CI 1.24–6.65] and sub- versus near-total resection (HR 2.10; 95 % CI 1.00–4.40). Complication comparisons between microscopy, endoscopy, and iMRI revealed increased perioperative deaths for endoscopy versus microscopy (4/209 and 0/237, respectively), but this difference was non-significant considering multiple post hoc comparisons (Fisher exact, p = 0.24). Conclusions Combined use of endoscopy and iMRI increased pituitary adenoma extent of resection status compared to conventional transsphenoidal microsurgery, and increased extent of resection status was associated with longer progression-free survival. Treatment modality combination did not significantly impact complication rate. PMID:24599833
From POEM to POET: Applications and perspectives for submucosal tunnel endoscopy.
Chiu, Philip W Y; Inoue, Haruhiro; Rösch, Thomas
2016-12-01
Recent advances in submucosal endoscopy have unlocked a new horizon for potential development in diagnostic and therapeutic endoscopy. Increasing evidence has demonstrated that peroral endoscopic myotomy (POEM) is not only clinically feasible and safe, but also has excellent results in symptomatic relief of achalasia. The success of submucosal endoscopy in performance of tumor resection has confirmed the potential of this new area in diagnostic and therapeutic endoscopy. This article reviews the current applications and evidence, from POEM to peroral endoscopic tunnel resection (POET), while exploring the possible future clinical applications in this field. © Georg Thieme Verlag KG Stuttgart · New York.
Tomizawa, Minoru; Shinozaki, Fuminobu; Hasegawa, Rumiko; Togawa, Akira; Shirai, Yoshinori; Ichiki, Noboru; Motoyoshi, Yasufumi; Sugiyama, Takao; Yamamoto, Shigenori; Sueishi, Makoto
2014-02-07
To investigate the early upper gastrointestinal endoscopy (endoscopy) significantly reduces mortality resulting from upper gastrointestinal (GI) bleeding. Upper GI bleeding was defined as 1a, 1b, 2a, and 2b according to the Forrest classification. The hemoglobin (Hb), and C-reactive protein (CRP) were examined at around the day of endoscopy and 3 mo prior to endoscopy. The rate of change was calculated as follows: (the result of blood examination on the day of endoscopy - the results of blood examination 3 mo prior to endoscopy)/(results of blood examination 3 mo prior to endoscopy). Receiver operating characteristic curves were created to determine threshold values. Seventy-nine men and 77 women were enrolled. There were 17 patients with upper GI bleeding: 12 with a gastric ulcer, 3 with a duodenal ulcer, 1 with an acute gastric mucosal lesion, and 1 with gastric cancer. The area under the curve (AUC), threshold, sensitivity, and specificity of Hb around the day of endoscopy were 0.902, 11.7 g/dL, 94.1%, and 77.1%, respectively, while those of CRP were 0.722, 0.5 mg/dL, 70.5%, and 73%, respectively. The AUC, threshold, sensitivity, and specificity of the rate of change of Hb were 0.851, -21.3%, 76.4%, and 82.6%, respectively, while those of CRP were 0.901, 100%, 100%, and 82.5%, respectively. Predictors for upper GI bleeding were Hb < 11.7 g/dL, reduction rate in the Hb > 21.3% and an increase in the CRP > 100%, 3 mo before endoscopy.
Armstrong, David; Barkun, Alan; Bridges, Ron; Carter, Rose; de Gara, Chris; Dubé, Catherine; Enns, Robert; Hollingworth, Roger; MacIntosh, Donald; Borgaonkar, Mark; Forget, Sylviane; Leontiadis, Grigorios; Meddings, Jonathan; Cotton, Peter; Kuipers, Ernst J; Valori, Roland
2012-01-01
BACKGROUND: Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality, highlight the need for clearly defined, evidence-based processes to support quality improvement in endoscopy. OBJECTIVE: To identify processes and indicators of quality and safety relevant to high-quality endoscopy service delivery. METHODS: A multidisciplinary group of 35 voting participants developed recommendation statements and performance indicators. Systematic literature searches generated 50 initial statements that were revised iteratively following a modified Delphi approach using a web-based evaluation and voting tool. Statement development and evidence evaluation followed the AGREE (Appraisal of Guidelines, REsearch and Evaluation) and GRADE (Grading of Recommendations, Assessment, Development and Evaluation) guidelines. At the consensus conference, participants voted anonymously on all statements using a 6-point scale. Subsequent web-based voting evaluated recommendations for specific, individual quality indicators, safety indicators and mandatory endoscopy reporting fields. Consensus was defined a priori as agreement by 80% of participants. RESULTS: Consensus was reached on 23 recommendation statements addressing the following: ethics (statement 1: agreement 100%), facility standards and policies (statements 2 to 9: 90% to 100%), quality assurance (statements 10 to 13: 94% to 100%), training, education, competency and privileges (statements 14 to 19: 97% to 100%), endoscopy reporting standards (statements 20 and 21: 97% to 100%) and patient perceptions (statements 22 and 23: 100%). Additionally, 18 quality indicators (agreement 83% to 100%), 20 safety indicators (agreement 77% to 100%) and 23 recommended endoscopy-reporting elements (agreement 91% to 100%) were identified. DISCUSSION: The consensus process identified a clear need for high-quality clinical and outcomes research to support quality improvement in the delivery of endoscopy services. CONCLUSIONS: The guidelines support quality improvement in endoscopy by providing explicit recommendations on systematic monitoring, assessment and modification of endoscopy service delivery to yield benefits for all patients affected by the practice of gastrointestinal endoscopy. PMID:22308578
The effect of upper gastrointestinal system endoscopy process on serum oxidative stress levels.
Turan, Mehmet Nuri; Aslan, Mehmet; Bolukbas, Filiz Fusun; Bolukbas, Cengiz; Selek, Sahbettin; Sabuncu, Tevfik
2016-12-01
Some authors have investigated the effects of oxidative stress in some process such as undergoing laparoscopic. However, the effect of upper gastrointestinal system endoscopy process on oxidative stress is unclear. We evaluated the short-term effect of upper gastrointestinal system endoscopy process on oxidative stress. Thirty patients who underwent endoscopy process and 20 healthy controls were enrolled in the prospective study. Serum total antioxidant capacity and total oxidant status measurements were measured before and after endoscopy process. The ratio percentage of total oxidant status to total antioxidant capacity was regarded as oxidative stress index. Before endoscopy process, serum total antioxidant capacity levels were higher, while serum total oxidant status levels and oxidative stress index values were lower in patients than controls, but this difference was not statistically significant (all, p > 0.05). After endoscopy process, serum total antioxidant capacity and total oxidant status levels were significantly higher in patients than before endoscopy process (both, p < 0.05). However, oxidative stress index values were slight higher in patients but this difference was not statistically significant (p > 0.05). We observed that serum TAC and TOS levels were increased in patients who underwent endoscopy process after endoscopy process. However, short-time upper gastrointestinal system endoscopy process did not cause an important change in the oxidative stress index. Further studies enrolling a larger number of patients are required to clarify the results obtained here.
Shokouhi, Bahman N; Khan, Mohammad; Carter, Martyn J; Khan, Nasser Q; Mills, Philip; Morris, Danielle; Rowlands, David E; Samsheer, Kote; Sargeant, Ian R; McIntyre, Peter B; Greenfield, Simon M
2013-07-01
Acute upper gastrointestinal bleeding (AUGIB) results in 25 000 hospital admissions annually. Patients admitted at weekends with AUGIB have increased mortality, and guidelines advise out-of-hours endoscopy. We present retrospective data from our service involving the interhospital transfer of patients. We pooled resources of two neighbouring general hospitals, just north of London. Emergency endoscopy is performed at the start of the list followed by elective endoscopy in the endoscopy unit on Saturday and Sunday mornings. From Friday evening to Sunday morning, patients admitted to Queen Elizabeth II Hospital (QEII) are medically stabilised and transferred to Lister Hospital by ambulance. 240 endoscopies were performed out of hours from December 2007 to March 2011. Of these, 54 patients were transferred: nine had emergency endoscopy at QEII as they were medically unstable; eight of the patients transferred required therapeutic intervention for active bleeding. The mean pre-endoscopy Rockall score of those transferred was 2.5. We examined the records of 51 of the 54 patients transferred. There were three deaths within 30 days after endoscopy not associated with the transfer process. 19 (37%) patients had reduced hospitalisation after having their endoscopy at the weekend. The introduction of the out-of-hours endoscopy service in our trust has had multiple benefits, including patients consistently receiving timely emergency endoscopy, significantly reduced disruption to emergency operating theatres, and participation of endoscopy nurses ensures a better and safer experience for patients, and better endoscopy decontamination. We suggest our model is safe and feasible for other small units wishing to set up their own out-of-hours endoscopy service to adopt.
Shokouhi, Bahman N; Khan, Mohammad; Carter, Martyn J; Khan, Nasser Q; Mills, Philip; Morris, Danielle; Rowlands, David E; Samsheer, Kote; Sargeant, Ian R; McIntyre, Peter B; Greenfield, Simon M
2013-01-01
Objective Acute upper gastrointestinal bleeding (AUGIB) results in 25 000 hospital admissions annually. Patients admitted at weekends with AUGIB have increased mortality, and guidelines advise out-of-hours endoscopy. We present retrospective data from our service involving the interhospital transfer of patients. Design We pooled resources of two neighbouring general hospitals, just north of London. Emergency endoscopy is performed at the start of the list followed by elective endoscopy in the endoscopy unit on Saturday and Sunday mornings. From Friday evening to Sunday morning, patients admitted to Queen Elizabeth II Hospital (QEII) are medically stabilised and transferred to Lister Hospital by ambulance. Results 240 endoscopies were performed out of hours from December 2007 to March 2011. Of these, 54 patients were transferred: nine had emergency endoscopy at QEII as they were medically unstable; eight of the patients transferred required therapeutic intervention for active bleeding. The mean pre-endoscopy Rockall score of those transferred was 2.5. We examined the records of 51 of the 54 patients transferred. There were three deaths within 30 days after endoscopy not associated with the transfer process. 19 (37%) patients had reduced hospitalisation after having their endoscopy at the weekend. Conclusions The introduction of the out-of-hours endoscopy service in our trust has had multiple benefits, including patients consistently receiving timely emergency endoscopy, significantly reduced disruption to emergency operating theatres, and participation of endoscopy nurses ensures a better and safer experience for patients, and better endoscopy decontamination. We suggest our model is safe and feasible for other small units wishing to set up their own out-of-hours endoscopy service to adopt. PMID:28839729
Osawa, Hiroyuki; Yamamoto, Hironori
2014-01-01
The usefulness of flexible spectral imaging color enhancement (FICE) has been reported for evaluating the esophagus, stomach, and small and large intestine. Higher contrast is shown between cancer and the surrounding mucosa in the esophagus and stomach and may facilitate the detection of gastric cancers missed by white light imaging alone. The surface patterns of gastric mucosa are clearly visualized in non-malignant areas but are irregular and blurred in malignant areas, leading to clear demarcation. Capsule endoscopy with FICE detects angiodysplasia and erosions of the small intestine. The surface and vascular pattern with FICE is useful for the differential diagnosis of colorectal polyps. However, FICE remains somewhat poor at visualizing mucosal microvasculature on a tumor surface. Narrow-band imaging (NBI) is dark in observing whole gastric mucosa and poor at visualizing mucosal microstructure. Blue laser imaging (BLI) has the potential to resolve these limitations. Narrow-band laser light combined with white light shows irregular microvessels on both differentiated and undifferentiated gastric cancer similar to those using NBI. In addition, irregular surface patterns including minute white zones are clearly seen on the uneven surface of differentiated lesions, resulting in exclusion of undifferentiated lesions. Using both distant and close-up views, a high contrast between green intestinal metaplasia and brown gastric cancer may lead to early detection of gastric cancers and determination of a demarcation line. BLI produces high-contrast images in esophageal cancer with clear vision of intrapapillary capillary loops and also predicts the histopathological diagnosis and depth of invasion in colorectal neoplasms. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.
Obscure recurrent gastrointestinal bleeding: a revealed mystery?
Riccioni, Maria Elena; Urgesi, Riccardo; Cianci, Rossella; Marmo, Clelia; Galasso, Domenico; Costamagna, Guido
2014-08-01
Nowadays, capsule endoscopy (CE) is the first-line procedure after negative upper and lower gastrointestinal (GI) endoscopy for obscure gastrointestinal bleeding (OGIB). Approximately, two-thirds of patients undergoing CE for OGIB will have a small-bowel abnormality. However, several patients who underwent CE for OGIB had the source of their blood loss in the stomach or in the colon. The aim of the present study is to determine the incidence of bleeding lesions missed by the previous gastroscopy/colonoscopy with CE and to evaluate the indication to repeat a new complete endoscopic workup in subjects related to a tertiary center for obscure bleeding before CE. We prospectively reviewed data from 637/1008 patients underwent to CE for obscure bleeding in our tertiary center after performing negative gastroscopy and colonoscopy. CE revealed a definite or likely cause of bleeding in stomach in 138/637 patients (yield 21.7%) and in the colon in 41 patients (yield 6.4%) with a previous negative gastroscopy and colonoscopy, respectively. The lesions found were outside the small bowel in only 54/637 (8.5%) patients. In 111/138 patients, CE found lesions both in stomach and small bowel (small-bowel erosions in 54, AVMs in 45, active small-bowel bleeding in 4, neoplastic lesions in 3 and distal ileum AVMs in 5 patients). In 24/41 (58.5%) patients, CE found lesions both in small bowel and colon (multiple small-bowel erosions in 15; AVMs in 8 and neoplastic lesion in 1 patients. All patients underwent endoscopic therapy or surgery for their nonsmall-bowel lesions. Lesions in upper or lower GI tract have been missed in about 28% of patients submitted to CE for obscure bleeding. CE may play an important role in identifying lesions missed at conventional endoscopy.
Haisley, Kelly R; Dolan, James P; Olson, Susan B; Toledo-Valdovinos, Sergio A; Hart, Kyle D; Bakis, Gene; Enestvedt, Brintha K; Hunter, John G
2017-02-01
Sponge cytology is a novel screening tool for esophageal cancer but has been unable to be validated for widespread use. Our aim was to apply fluorescent in situ hybridization to sponge cytology samples in order to evaluate the safety and efficacy of this modality in screening for esophageal cancer. At a single, multidisciplinary, NCI-designated cancer center, patients completed sponge cytology sampling prior to upper endoscopy. Samples were analyzed by p53 fluorescent in situ hybridization, and results were compared to the endoscopic diagnosis. Fifty patients were enrolled (96 % Caucasian, 68 % male, median age of 67). All patients successfully swallowed the capsule. No complications (string breakage, bleeding, mucosal injury) occurred. Endoscopy revealed that 38 % had normal esophageal mucosa and 62 % had an esophageal mucosal abnormality. In total, six samples demonstrated p53 loss (94 % specificity for any abnormality). The sensitivity of the p53 fluorescent in situ hybridization probe was13.3 % for any abnormality, 10 % for intestinal metaplasia, and 0 % for dysplasia or esophageal cancer. Esophageal sponge cytology is a promising, safe, and tolerable method for collecting esophageal cell samples. However, our data suggest that p53 fluorescent in situ hybridization does not improve the sensitivity for detecting cancer in these samples.
2009-01-01
Background Discrete choice experiments (DCEs) allow systematic assessment of preferences by asking respondents to choose between scenarios. We conducted a labelled discrete choice experiment with realistic choices to investigate patients' trade-offs between the expected health gains and the burden of testing in surveillance of Barrett esophagus (BE). Methods Fifteen choice scenarios were selected based on 2 attributes: 1) type of test (endoscopy and two less burdensome fictitious tests), 2) frequency of surveillance. Each test-frequency combination was associated with its own realistic decrease in risk of dying from esophageal adenocarcinoma. A conditional logit model was fitted. Results Of 297 eligible patients (155 BE and 142 with non-specific upper GI symptoms), 247 completed the questionnaire (84%). Patients preferred surveillance to no surveillance. Current surveillance schemes of once every 1–2 years were amongst the most preferred alternatives. Higher health gains were preferred over those with lower health gains, except when test frequencies exceeded once a year. For similar health gains, patients preferred video-capsule over saliva swab and least preferred endoscopy. Conclusion This first example of a labelled DCE using realistic scenarios in a healthcare context shows that such experiments are feasible. A comparison of labelled and unlabelled designs taking into account setting and research question is recommended. PMID:19454022
Comparison of methods for quantitative evaluation of endoscopic distortion
NASA Astrophysics Data System (ADS)
Wang, Quanzeng; Castro, Kurt; Desai, Viraj N.; Cheng, Wei-Chung; Pfefer, Joshua
2015-03-01
Endoscopy is a well-established paradigm in medical imaging, and emerging endoscopic technologies such as high resolution, capsule and disposable endoscopes promise significant improvements in effectiveness, as well as patient safety and acceptance of endoscopy. However, the field lacks practical standardized test methods to evaluate key optical performance characteristics (OPCs), in particular the geometric distortion caused by fisheye lens effects in clinical endoscopic systems. As a result, it has been difficult to evaluate an endoscope's image quality or assess its changes over time. The goal of this work was to identify optimal techniques for objective, quantitative characterization of distortion that are effective and not burdensome. Specifically, distortion measurements from a commercially available distortion evaluation/correction software package were compared with a custom algorithm based on a local magnification (ML) approach. Measurements were performed using a clinical gastroscope to image square grid targets. Recorded images were analyzed with the ML approach and the commercial software where the results were used to obtain corrected images. Corrected images based on the ML approach and the software were compared. The study showed that the ML method could assess distortion patterns more accurately than the commercial software. Overall, the development of standardized test methods for characterizing distortion and other OPCs will facilitate development, clinical translation, manufacturing quality and assurance of performance during clinical use of endoscopic technologies.
Collagenous Gastritis a Rare Disorder in Search of a Disease
Mandaliya, Rohan; DiMarino, Anthony J.; Abraham, Sheeja; Burkart, Ashlie; Cohen, Sidney
2013-01-01
A 19-year-old young male presented with abdominal pain and constipation. Subsequent EGD showed nodular gastric mucosa with simple gastric aspirate demonstrating acidic pH of 2.0. The gastric biopsy showed thick subepithelial band of about 15 microns that was confirmed to be collagen on Masson’s trichrome stain along with inflammatory infiltrate. Colonoscopy and capsule endoscopy findings were unremarkable as well as the biopsy of the colon. Collagenous gastritis is a rare histopathological entity characterized by the presence of thick subepithelial collagen band of thickness greater than 10 microns along with intraepithelial lymphocytes and lamina propria lymphoplasmacytic and eosinophilic infitrates. Clinical presentation varies and depends more on the age of the patient with anemia or epigastric pain with nodular gastric mucosa being more common in children while diarrhea being more common in adults due to its increased association with collagenous colitis. The purpose of this case report is; (A) To define the endoscopic and histopathological features and progression of collagenous gastritis in this patient; (B) To compare these findings to those of collagenous sprue and collagenous colitis. PMID:27785244
Murdani, Abdullah; Kumar, Ajay; Chiu, Han-Mo; Goh, Khean-Lee; Jang, Byung Ik; Khor, Christopher J L; Lau, James; Mostafa, Ibrahim; Ramchandani, Mohan; Ratanalert, Siriporn; Tajiri, Hisao; Yuen, Minghwa; Zhang, Shu Tian; Duforest-Rey, Dianelle; Rey, Jean-Francois
2017-01-01
The aim of this position statement is to reinforce the key points of hygiene in digestive endoscopy. The present article details the minimum hygiene requirements for reprocessing of endoscopes and endoscopic devices, regardless of the reprocessing method (automated washer-disinfector or manual cleaning) and the endoscopy setting (endoscopy suite, operating room, elective or emergency procedures). These minimum requirements are mandatory for patient safety. Both advanced diagnostic and therapeutic endoscopies should be carried out in an environment that is safe for patients and staff. Particular attention is given to contaminants. Procedural errors in decontamination, defective equipment, and failure to follow disinfection guidelines are major factors contributing to transmission of infection during endoscopy. Other important risk factors include inadequate cleaning, use of older endoscopes with surface and working channel irregularities, and contamination of water bottles or irrigating solutions. Infections by multidrug-resistant organisms have become an increasing problem in health-care systems worldwide. Since 2010, outbreaks of multidrug-resistant bacteria associated with endoscopic retrograde cholangiopancreatography have been reported from the USA, France, Germany, and The Netherlands. In many endoscopy units in Asia and the Middle East, reprocessing procedures have lagged behind those of Western countries for cultural reasons or lack of financial resources. This inconsistency in standards is now being addressed, and the World Endoscopy Organization has prepared this position statement to highlight key points for quality assurance in any endoscopy unit in any country. © 2016 Japan Gastroenterological Endoscopy Society.
Abang, Sariah; Chan, Eng-Seng; Poncelet, Denis
2012-01-01
The objective of this study was to investigate the effects of process variables on the encapsulation of oil in a calcium alginate membrane using an inverse gelation technique. A dispersion of calcium chloride solution in sunflower oil (water-in-oil emulsion) was added dropwise to the alginate solution. The migration of calcium ions to the alginate solution initiates the formation of a ca-alginate membrane around the emulsion droplets. The membrane thickness of wet capsules and the elastic modulus of dry capsules increased following first-order kinetics with an increasing curing time. An increase in the calcium chloride concentration increased the membrane thickness of wet capsules and the elastic modulus of dry capsules. An increase in the alginate concentration decreased the mean diameter of wet capsules but increased the elastic modulus of dry capsules.
Endoscopy and General Surgery - Parts of the Same Activity.
Doran, Horia; Pătraşcu, Traian
2016-01-01
In general and digestive surgical departments, an accurate diagnosis and appropriate treatment of our patients require a wide and continuous access to endoscopy. As many surgical clinics have already developed their own endoscopy units, we plead for the future presence of at least 1 or 2 surgeons, board certified in endoscopy, in every surgical department. We have retrospectively analyzed the activity of the endoscopic unit as a part of the Surgical Clinic of "Dr. I. Cantacuzino" Clinical Hospital since 2007, when it was settled, and its benefits, regarding a higher accessibility for our patients and a reliable support for all the doctors. The number of procedures has increased constantly, from 137, performed by 2 surgeons in 2007 to 1546, in 2015, when 7 surgeons were able to get involved in endoscopic procedures, on a 24/7 schedule. The etiological diagnosis of gastrointestinal hemorrhages, the early detection of gastric, colonic and upper rectal tumors, the follow-up of oncologic patients are only a few of the fields in which endoscopy proved its benefits. Furthermore, surgeons have the practical training and the legal board certification for the approach and treatment of complications. An increased number of surgeons who have also board certification in endoscopy cannot be but very useful. The best way to accomplish this goal would be the inclusion of a digestive endoscopy module during the training program of all future general surgeons. Celsius.
[Management of Patients on Antithrombotic Agents Undergoing Endoscopy].
Kim, Joon Sung; Kim, Byung Wook
2018-05-25
Antithrombotic agents are used increasingly in Asia. The management of patients on antithrombotics undergoing elective or emergency endoscopy has become an increasing clinical challenge for gastroenterologists. Current practice guidelines have been developed by societies from western countries. On the other hand, these guidelines cannot meet the specific needs of the Asian Pacific region, raising the need for separate guidelines in Asia. This review compares the recommendations of previous guidelines with the most recently published Asian guidelines regarding the management of patients on antithrombotic agents undergoing elective and emergency endoscopy.
Light and sound - emerging imaging techniques for inflammatory bowel disease
Knieling, Ferdinand; Waldner, Maximilian J
2016-01-01
Patients with inflammatory bowel disease are known to have a high demand of recurrent evaluation for therapy and disease activity. Further, the risk of developing cancer during the disease progression is increasing from year to year. New, mostly non-radiant, quick to perform and quantitative methods are challenging, conventional endoscopy with biopsy as gold standard. Especially, new physical imaging approaches utilizing light and sound waves have facilitated the development of advanced functional and molecular modalities. Besides these advantages they hold the promise to predict personalized therapeutic responses and to spare frequent invasive procedures. Within this article we highlight their potential for initial diagnosis, assessment of disease activity and surveillance of cancer development in established techniques and recent advances such as wide-view full-spectrum endoscopy, chromoendoscopy, autofluorescence endoscopy, endocytoscopy, confocal laser endoscopy, multiphoton endoscopy, molecular imaging endoscopy, B-mode and Doppler ultrasound, contrast-enhanced ultrasound, ultrasound molecular imaging, and elastography. PMID:27433080
Mohamed, Rachid; Raman, Maitreyi; Anderson, John; McLaughlin, Kevin; Rostom, Alaa; Coderre, Sylvain
2014-03-01
Although workplace workload assessments exist in different fields, an endoscopy-specific workload assessment tool is lacking. To validate such a workload tool and use it to map the progression of novice trainees in gastroenterology in performing their first endoscopies. The National Aeronautics and Space Administration Task Load Index (NASA-TLX) workload assessment tool was completed by eight novice trainees in gastroenterology and 10 practicing gastroenterologists⁄surgeons. An exploratory factor analysis was performed to construct a streamlined endoscopy-specific task load index, which was subsequently validated. The 'Endoscopy Task Load Index' was used to monitor progression of trainee exertion and self-assessed performance over their first 40 procedures. From the factor analysis of the NASA-TLX, two principal components emerged: a measure of exertion and a measure of self-efficacy. These items became the components of the newly validated Endoscopy Task Load Index. There was a steady decline in self-perceived exertion over the training period, which was more rapid for gastroscopy than colonoscopy. The self-efficacy scores for gastroscopy rapidly increased over the first few procedures, reaching a plateau after this period of time. For colonoscopy, there was a progressive increase in reported self-efficacy over the first three quartiles of procedures, followed by a drop in self-efficacy scores over the final quartile. The present study validated an Endoscopy Task Load Index that can be completed in <1 min. Practical implications of such a tool in endoscopy education include identifying periods of higher perceived exertion among novice endoscopists, facilitating appropriate levels of guidance from trainers.
MacIntosh, Donald; Dubé, Catherine; Hollingworth, Roger; van Zanten, Sander Veldhuyzen; Daniels, Sandra; Ghattas, George
2013-01-01
BACKGROUND: Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality highlight the need for endoscopy facilities to review the quality of the service they offer. OBJECTIVE: To adapt the United Kingdom Global Rating Scale (UK-GRS) to develop a web-based and patient-centred tool to assess and improve the quality of endoscopy services provided. METHODS: Based on feedback from 22 sites across Canada that completed the UK endoscopy GRS, and integrating results of the Canadian consensus on safety and quality indicators in endoscopy and other Canadian consensus reports, a working group of endoscopists experienced with the GRS developed the GRS-Canada (GRS-C). RESULTS: The GRS-C mirrors the two dimensions (clinical quality and quality of the patient experience) and 12 patient-centred items of the UK-GRS, but was modified to apply to Canadian health care infrastructure, language and current practice. Each item is assessed by a yes/no response to eight to 12 statements that are divided into levels graded D (basic) through A (advanced). A core team consisting of a booking clerk, charge nurse and the physician responsible for the unit is recommended to complete the GRS-C twice yearly. CONCLUSION: The GRS-C is intended to improve endoscopic services in Canada by providing endoscopy units with a straightforward process to review the quality of the service they provide. PMID:23472242
Biopsy applications of Ti50Ni41Cu9 shape memory films for wireless capsule endoscope
NASA Astrophysics Data System (ADS)
Du, Hejun; Fu, Yongqing; Zhang, S.; Luo, Jack K.; Flewitt, Andrew J.; Milne, William I.
2004-02-01
Wireless capsule endoscopy (WCE) is a new technology to evaluate the patient with obscure gastrointestinal bleeding. However, there is still some deficiency existing in the current WCE, for example, lack of ability to biopsy and precisely locate the pathology. This study aimed to prepare and characterize TiNiCu shape memory alloy thin films for developing microgripper for biopsy (tissue sampling and tagging) applications. Ti50Ni41Cu9 thin films were prepared by co-sputtering of TiNi and Cu targets, and their transformation temperatures were slightly above that of human body. Results from differential scanning calorimetry, in-situ X-ray diffraction, curvature and electrical resistance measurement revealed clearly martensitic transformation of the deposited TiNiCu films upon heating and cooling. The biocompatibility of the TiNiCu films in the simulated gastric and intestinal solutions was also studied. Results showed the release of Ni and Cu ions is much less than the toxic level and the film did not lose shape memory effect even after 10-day immersion in the simulated solutions. TiNiCu/Si micro-cantilevers with and without electrodes were fabricated using the conventional micromachining methods and apparent shape memory effect upon heating and cooling was demonstrated.
Mohamed, Rachid; Raman, Maitreyi; Anderson, John; McLaughlin, Kevin; Rostom, Alaa; Coderre, Sylvain
2014-01-01
BACKGROUND: Although workplace workload assessments exist in different fields, an endoscopy-specific workload assessment tool is lacking. OBJECTIVE: To validate such a workload tool and use it to map the progression of novice trainees in gastroenterology in performing their first endoscopies. METHODS: The National Aeronautics and Space Administration Task Load Index (NASA-TLX) workload assessment tool was completed by eight novice trainees in gastroenterology and 10 practicing gastroenterologists/surgeons. An exploratory factor analysis was performed to construct a streamlined endoscopy-specific task load index, which was subsequently validated. The ‘Endoscopy Task Load Index’ was used to monitor progression of trainee exertion and self-assessed performance over their first 40 procedures. RESULTS: From the factor analysis of the NASA-TLX, two principal components emerged: a measure of exertion and a measure of self-efficacy. These items became the components of the newly validated Endoscopy Task Load Index. There was a steady decline in self-perceived exertion over the training period, which was more rapid for gastroscopy than colonoscopy. The self-efficacy scores for gastroscopy rapidly increased over the first few procedures, reaching a plateau after this period of time. For colonoscopy, there was a progressive increase in reported self-efficacy over the first three quartiles of procedures, followed by a drop in self-efficacy scores over the final quartile. DISCUSSION: The present study validated an Endoscopy Task Load Index that can be completed in <1 min. Practical implications of such a tool in endoscopy education include identifying periods of higher perceived exertion among novice endoscopists, facilitating appropriate levels of guidance from trainers. PMID:24619638
Motion of an elastic capsule in a square microfluidic channel.
Kuriakose, S; Dimitrakopoulos, P
2011-07-01
In the present study we investigate computationally the steady-state motion of an elastic capsule along the centerline of a square microfluidic channel and compare it with that in a cylindrical tube. In particular, we consider a slightly over-inflated elastic capsule made of a strain-hardening membrane with comparable shearing and area-dilatation resistance. Under the conditions studied in this paper (i.e., small, moderate, and large capsules at low and moderate flow rates), the capsule motion in a square channel is similar to and thus governed by the same scaling laws with the capsule motion in a cylindrical tube, even though in the channel the cross section in the upstream portion of large capsules is nonaxisymmetric (i.e., square-like with rounded corners). When the hydrodynamic forces on the membrane increase, the capsule develops a pointed downstream edge and a flattened rear (possibly with a negative curvature) so that the restoring tension forces are increased as also happens with droplets. Membrane tensions increase significantly with the capsule size while the area near the downstream tip is the most probable to rupture when a capsule flows in a microchannel. Because the membrane tensions increase with the interfacial deformation, a suitable Landau-Levich-Derjaguin-Bretherton analysis reveals that the lubrication film thickness h for large capsules depends on both the capillary number Ca and the capsule size a; our computations determine the latter dependence to be (in dimensionless form) h ~ a(-2) for the large capsules studied in this work. For small and moderate capsule sizes a, the capsule velocity Ux and additional pressure drop ΔP+ are governed by the same scaling laws as for high-viscosity droplets. The velocity and additional pressure drop of large thick capsules also follow the dynamics of high-viscosity droplets, and are affected by the lubrication film thickness. The motion of our large thick capsules is characterized by a Ux-U ~ h ~ a(-2) approach to the undisturbed average duct velocity and an additional pressure drop ΔP+ ~a(3)/h ~ a(5). By combining basic physical principles and geometric properties, we develop a theoretical analysis that explains the power laws we found for large capsules.
Purgative bowel cleansing combined with simethicone improves capsule endoscopy imaging.
Wei, Wei; Ge, Zhi-Zheng; Lu, Hong; Gao, Yun-Jie; Hu, Yun-Biao; Xiao, Shu-Dong
2008-01-01
To evaluate the effects of the various methods of small bowel preparation on the quality of visualization of the small bowel and the gastrointestinal transit time of capsule endoscopy (CE). Ninety patients referred for CE were prospectively randomized to three equal groups according to the preparation used: (a) a control group, in which patients were requested to drink 1 L of clear liquids only, 12 h before the examination; (b) a purgative group, in which patients were requested to ingest 1 L of a polyethylene glycol (PEG)/electrolyte solution only, 12 h before the examination; or (c) a purgative combined with simethicone group (P-S group), in which patients were requested to ingest 1 L of PEG, 12 h before the examination, and 300 mg of simethicone, 20 min before the examination. Effects of the different bowel preparations on the gastric transit time (GTT), small bowel transit time (SBTT), examination completion rate, quality of images of the entire small intestine, and cleansing of the proximal small bowel and distal ileum were evaluated. The number of patients with "adequate" cleansing of the entire small intestine was 17 in the P-S group, 12 in the purgative group, and seven in the control group (P= 0.002). The P-S group had significantly better image quality than the control group (P= 0.001). The P-S group had significantly better image quality for the proximal small bowel (segment A [Seg A]) than the control group (P= 0.0001). Both the P-S group (P= 0.0001) and the purgative group (P= 0.0002) had significantly better image quality for the distal ileum (segment B [Seg B]) than the control group; the P-S group had significantly better image quality than the purgative group as well (P= 0.0121). Gastrointestinal transit time was not different among the three groups, nor was the examination completion rate. Purgative bowel cleansing combined with simethicone before CE improved the quality of imaging of the entire small bowel as well as the visualization of the mucosa in the proximal and distal small intestine.
Sato, Yasushi; Sagawa, Tamotsu; Hirakawa, Masahiro; Ohnuma, Hiroyuki; Osuga, Takahiro; Okagawa, Yutaka; Tamura, Fumito; Horiguchi, Hiroto; Takada, Kohichi; Hayashi, Tsuyoshi; Sato, Tsutomu; Miyanishi, Koji; Takimoto, Rishu; Kobune, Masayoshi; Kato, Junji
2014-01-01
Background and study aims: The clinical utility of computed virtual chromoendoscopy with flexible spectral imaging color enhancement (FICE) in capsule endoscopy (CE) remains controversial. To clarify the clinical utility of FICE-enhanced CE in evaluating small bowel lesions, we quantitatively assessed white light (WL), FICE, and blue mode (BM) images and examined the sensitivity of these 3 imaging modes of small-bowel lesions from patients who underwent CE. Methods: The CIELAB color difference (∆E) and visual analogue scales (VAS) were measured in 261 CE images (3 different lesion categories) using WL and FICE set 1, 2, and 3, and BM images, respectively. Three endoscopists reviewed CE videos with WL, 3 FICE mode settings, and BM, and compared the sensitivity and detectability for small intestinal diseases from 50 patients who underwent CE. Results: In the assessment of visibility in the 152 vascular lesion images, the ∆E and VAS of FICE set 1, 2, and BM images were significantly higher than that of WL images. In 88 erosion/ulceration images, the ∆E and VAS of FICE set 1 and 2 images were significantly higher than that of WL images. In 21 tumor images, there were no significant differences in ∆E among these modalities. When analyzed on a per-patient basis, FICE settings 1 and 2 had the highest sensitivity (100 %) and specificity (97.3 – 100 %) for vascular lesions. As for erosive/ulcerative lesions, FICE setting 2 had the highest sensitivity (100 %) and specificity (97.2 %). For tumors or polyps, WL had the highest sensitivity (90.9 %) and specificity (87.1 %). In per-lesion analysis, FICE settings 1 and 2 showed significantly superior detection ability over WL for vascular lesions. In the detection of erosive/ulcerative lesions, FICE setting 2 was significantly superior to WL. In tumor images, there was no significant improvement with any of the settings relative to WL images. Conclusions: FICE is most useful for improving CE image quality and detection in cases of angioectasia and erosion/ulceration of the small intestine. PMID:26135265
Cooper, Gregory S; Kou, Tzyung Doug; Wong, Richard C K
2009-08-01
Upper endoscopy performed within 1 day of presentation, or early endoscopy, has been proposed as an intervention to improve the efficiency and outcomes of care for patients with peptic ulcer hemorrhage. However, the use and outcomes have not been studied in a national, U.S.-based sample. To determine the prevalence and associated outcomes of early versus delayed endoscopy in bleeding peptic ulcers. Using a 5% random sample of inpatient and outpatient Medicare claims from 2004 in patients aged 66 years and older (mean [standard deviation] age 78.4 +/- 7.7 years), we identified 2592 patients, all of whom underwent endoscopy. Univariate and multivariate models were used to determine factors associated with 30-day mortality, upper GI surgery, and length of hospital stay. Early endoscopy was performed in 1854 patients (71.5%) and was somewhat more common with outpatient management. Early endoscopy was independently associated with a significant decrease in the length of hospital stay (-1.95 days, 95% CI, -2.60 to -1.29 days) as well as a lower likelihood of surgery (odds ratio, 0.37; 95% CI, 0.21-0.66). Early endoscopy was not associated with 30-day mortality in either univariate or multivariate analyses. Use of claims data lacking clinical detail and restriction to the Medicare-age population. In this population-based study of older patients with peptic ulcer hemorrhage, early endoscopy was associated with increased efficiency of care, lower rates of surgery, and potentially improved control of hemorrhage. Thus, unless specific contraindications exist, the data support the routine use of early endoscopy.
Fujiwara, Yasuhiro; Higuchi, Kazuhide; Shiba, Masatsugu; Yamamori, Kazuki; Watanabe, Yoko; Sasaki, Eiji; Tominaga, Kazunari; Watanabe, Toshio; Oshitani, Nobuhide; Arakawa, Tetsuo
2005-04-01
Helicobacter pylori infection and atrophic gastritis are inversely related to erosive esophagitis. Whether these factors affect the pathogenesis of endoscopy-negative reflux disease is not clear. We aimed to elucidate the differences in clinical characteristics between endoscopy-negative erosive disease and erosive esophagitis. 253 subjects (89 with endoscopy-negative reflux disease and 164 with erosive esophagitis) were studied. Gastric atrophy was assessed by measurement of serum pepsinogen. Logistic regression was used to calculate the odds ratio (OR) and 95% confidence intervals (CI) of endoscopy-negative reflux disease compared with erosive esophagitis. Among GERD patients, female gender (OR = 2.27, 95% CI, 1.25-4.10), smoking (OR = 0.45, 95% CI, 0.22-0.91), and the presence of hiatal hernia (OR = 0.30, 95% CI, 0.17-0.56) were significantly associated with endoscopy-negative reflux disease compared with male gender, not smoking, and absence of hiatal hernia, respectively. Body mass index (BMI) was also significantly associated with a decreased OR for endoscopy-negative reflux disease. Although H. pylori infection and gastric atrophy were significantly more common in patients with endoscopy-negative reflux disease, these associations did not persist in a multiple-adjustment model. After adjustment for gender, BMI, smoking, and hiatal hernia, a decrease in serum pepsinogen I/II ratio was significantly associated with an increased OR for endoscopy-negative reflux disease (p for trend = 0.018). Female gender, low BMI, not smoking, absence of hiatal hernia, and severity of gastric atrophy were positively associated with endoscopy-negative reflux disease compared with erosive esophagitis among Japanese patients.
Staffing levels in endoscopy units.
Ott, B J; Igo, M; Shields, N
1994-04-01
Staffing the endoscopy area has become increasingly complex. Growth in procedure volumes, changes in technology, and the application of endoscopy in the diagnosis and treatment of disease contribute to the complexities. The manager must deal with these changes, maintain costs, and still provide adequate staffing to ensure patient safety and quality care. The purpose of this article is to present the results of a laboratory manager survey conducted in 1990. Of 51 laboratory managers who responded, those who rated their laboratories to be adequately staffed averaged 4.2 hr per procedure. The survey results may be useful to laboratory managers seeking to calculate staff needs in a typical endoscopy area.
Primary small-bowel malignancy: update in tumor biology, markers, and management strategies.
Shenoy, Santosh
2014-12-01
Primary small-bowel malignancies (SBM) are rare tumors but their incidence is rising. An estimated 9160 new cases and 1210 deaths due to SBM may occur in the USA in 2014. We review advances made in tumor biology, immunohistochemistry, and discuss treatment strategies for these malignancies. Relevant articles from PubMed/Medline and Embase searches were collected using the phrases "small-bowel adenocarcinoma, gastrointestinal carcinoids, gastrointestinal stromal tumors, small-bowel leiomyosarcoma, and small-bowel lymphoma". Advances in imaging techniques such as wireless capsule endoscopy, CT and MRI enterography, and endoscopy (balloon enteroscopy) along with discovery of molecular markers such as c-kit and PDGFRA for GIST tumors have improved our ability to diagnose, localize, and treat these patients. Early detection and surgical resection offers the best chance for long-term survival in all tumors except bowel lymphoma where chemotherapy plays the main role. Adjuvant therapy with imatinib has improved overall survival for GIST tumors, somatostatin analogs have improved symptoms and also inhibited tumor growth and stabilized metastatic disease in carcinoid disease, but chemotherapy has not improved survival for adenocarcinoma. Recent advances in molecular characterization holds promise in novel targeted therapies. Currently ongoing trials are exploring efficacy of targeted therapies and role of adjuvant therapy for adenocarcinoma and results are awaited. Early detection and aggressive surgical therapy for all localized tumors and lymph node sampling particularly for adenocarcinoma remains the main treatment modality.
Nurse-Performed Endoscopy: Implications for the Nursing Profession in Australia.
Duffield, Christine; Chapman, Susan; Rowbotham, Samantha; Blay, Nicole
2017-02-01
Increasing demands for health care globally often lead to discussions about expanding the involvement of nurses in a range of nontraditional roles. Several countries have introduced nurse endoscopists as a means of easing the burden of demand for a range of endoscopic procedures. A shortage of medical staff in Australia combined with increasing demand for endoscopy led to the implementation of nurse endoscopists as a pilot program in the state of Queensland, where a nurse practitioner model was implemented, and Victoria, where an advanced practice model was used. This article will discuss the implementation of and responses from the nursing, medical, and policy community to nurse-performed endoscopy in this country. Regarding health policy, access to cancer screening may be improved by providing nurses with advanced training to safely perform endoscopy procedures. Moreover, issues of nurse credentialing and payment need to be considered appropriate to each country's health system model.
Azzam, Rimon Sobhi; Sallum, Rubens A A; Brandão, Jeovana Ferreira; Navarro-Rodriguez, Tomás; Nasi, Ary
2012-01-01
Esophageal pH monitoring is considered to be the gold standard for the diagnosis of gastroesophageal acid reflux. However, this method is very troublesome and considerably limits the patient's routine activities. Wireless pH monitoring was developed to avoid these restrictions. To compare the first 24 hours of the conventional and wireless pH monitoring, positioned 3 cm above the lower esophageal sphincter, in relation to: the occurrence of relevant technical failures, the ability to detect reflux and the ability to correlate the clinical symptoms to reflux. Twenty-five patients referred for esophageal pH monitoring and with typical symptoms of gastroesophageal reflux disease were studied prospectively, underwent clinical interview, endoscopy, esophageal manometry and were submitted, with a simultaneous initial period, to 24-hour catheter pH monitoring and 48-hour wireless pH monitoring. Early capsule detachment occurred in one (4%) case and there were no technical failures with the catheter pH monitoring (P = 0.463). Percentages of reflux time (total, upright and supine) were higher with the wireless pH monitoring (P < 0.05). Pathological gastroesophageal reflux occurred in 16 (64%) patients submitted to catheter and in 19 (76%) to the capsule (P = 0.355). The symptom index was positive in 12 (48%) patients with catheter pH monitoring and in 13 (52%) with wireless pH monitoring (P = 0.777). 1) No significant differences were reported between the two methods of pH monitoring (capsule vs catheter), in regard to relevant technical failures; 2) Wireless pH monitoring detected higher percentages of reflux time than the conventional pH-metry; 3) The two methods of pH monitoring were comparable in diagnosis of pathological gastroesophageal reflux and comparable in correlating the clinical symptoms with the gastroesophageal reflux.
Boström, Michaela; Thorsson, Ola; Toth, Ervin; Agardh, Daniel
2014-12-24
Wireless pH-monitoring is an accurate method for diagnosing adults with gastroesophageal reflux disease (GERD). The aim of this study was to evaluate the use of the Bravo capsule on children investigated for GERD in terms of safety, tolerability and feasibility before and after administration of proton pump inhibitors. A Bravo capsule was inserted during upper endoscopy under general anaesthesia or deep sedation with propofol. 48-hour pH-metry was performed in 106 children (50 males, 56 females) at the median age of 11 years (range 17 months-18 years). On the second day of investigation, proton pump inhibitor (PPI) was given at a mean dose of 1.6 mg/kg (SD ±0.6 mg). The definition of GERD was set to a reflux index (RI) of ≥5% and DeMeester score (DMS) ≥14.7. Application of the capsule was successful in 103 of the 106 children (97.2%) and interpretable in 99 of these 103 (96.1%). 49 of the children with interpretable results (49.5%) had GERD according to RI, while 51 (56.7%) had GERD according to DMS. After PPI was given on day 2, RI decreased from a median of 4.9% (range 0.3-63.4%) to 2.2% (0-58.0%), while DMS decreased from a median of 17.6 (range 2.2-207.6) to 8.2 (0.3-178.6), respectively (p < 0.0001). No severe adverse events were reported. Wireless pH-metry is a safe and tolerable method when investigating children for GERD. PPI given on the second day of assessment provides additional information on response to treatment suggesting that pH-metry preferably should be extended to 48 hours.
Improving the timeliness of procedures in a pediatric endoscopy suite.
Tomer, Gitit; Choi, Steven; Montalvo, Andrea; Sutton, Sheila; Thompson, John; Rivas, Yolanda
2014-02-01
Pediatric endoscopic procedures are essential in the evaluation and treatment of gastrointestinal diseases in children. Although pediatric endoscopists are greatly interested in increasing efficiency and through-put in pediatric endoscopy units, there is scarcely any literature on this critical process. The goal of this study was to improve the timeliness of pediatric endoscopy procedures at Children's Hospital at Montefiore. In June 2010, a pediatric endoscopy quality improvement initiative was formed at Children's Hospital at Montefiore. We identified patient-, equipment-, and physician-related causes for case delays. Pareto charts, cause and effect diagrams, process flow mapping, and statistical process control charts were used for analysis. From June 2010 to December 2012, we were able to significantly decrease the first case endoscopy delay from an average of 17 to 10 minutes (P < .001), second case delay from 39 to 25 minutes (P = .01), third case delay from 61 to 45 minutes (P = .05), and fourth case delay from 79 to 51 minutes (P = .05). Total delay time decreased from 196 to 131 minutes, resulting in a reduction of 65 minutes (P = .02). From June 2010 to August 2011 (preintervention period), an average of 36% of first endoscopy cases started within 5 minutes, 51% within 10 minutes, and 61% within 15 minutes of the scheduled time. From September 2011 to December 2012 (postintervention period), the percentage of cases starting within 5 minutes, 10 minutes, and 15 minutes increased to 47% (P = .07), 61% (P = .04), and 79% (P = .01), respectively. Applying quality improvement methods and tools helped improve pediatric endoscopy timeliness and significantly decreased total delays.
Geno, K. Aaron; Hauser, Jocelyn R.; Gupta, Kanupriya
2014-01-01
Streptococcus pneumoniae produces a protective capsular polysaccharide whose production must be modulated for bacterial survival within various host niches. Capsule production is affected in part by a phosphoregulatory system comprised of CpsB, CpsC, and CpsD. Here, we found that growth of serotype 2 strain D39 under conditions of increased oxygen availability resulted in decreased capsule levels concurrent with an ∼5-fold increase in Cps2B-mediated phosphatase activity. The change in Cps2B phosphatase activity did not result from alterations in the levels of either the cps2B transcript or the Cps2B protein. Recombinant Cps2B expressed in Escherichia coli similarly exhibited increased phosphatase activity under conditions of high-oxygen growth. S. pneumoniae D39 derivatives with defined deletion or point mutations in cps2B demonstrated reduced phosphatase activity with corresponding increases in levels of Cps2D tyrosine phosphorylation. There was, however, no correlation between these phenotypes and the level of capsule production. During growth under reduced-oxygen conditions, the Cps2B protein was essential for parental levels of capsule, but phosphatase activity alone could be eliminated without an effect on capsule. Under increased-oxygen conditions, deletion of cps2B did not affect capsule levels. These results indicate that neither Cps2B phosphatase activity nor Cps2D phosphorylation levels per se are determinants of capsule levels, whereas the Cps2B protein is important for capsule production during growth under conditions of reduced but not enhanced oxygen availability. Roles for factors outside the capsule locus, possible interactions between capsule regulatory proteins, and links to other cellular processes are also suggested by the results described in this study. PMID:24659769
Motion of an elastic capsule in a square microfluidic channel
Kuriakose, S.; Dimitrakopoulos, P.
2013-01-01
In the present study we investigate computationally the steady-state motion of an elastic capsule along the centerline of a square microfluidic channel and compare it with that in a cylindrical tube. In particular, we consider a slightly over-inflated elastic capsule made of a strain-hardening membrane with comparable shearing and area-dilatation resistance. Under the conditions studied in this paper (i.e. small, moderate and large capsules at low and moderate flow rates), the capsule motion in a square channel is similar to, and thus governed by the same scaling laws with the capsule motion in a cylindrical tube, even though in the channel the cross-section in the upstream portion of large capsules is non-axisymmetric (i.e. square-like with rounded corners). When the hydrodynamic forces on the membrane increase, the capsule develops a pointed downstream edge and a flattened rear (possibly with a negative curvature) so that the restoring tension forces are increased as also happens with droplets. Membrane tensions increase significantly with the capsule size while the area near the downstream tip is the most probable to rupture when a capsule flows in a microchannel. Because the membrane tensions increase with the interfacial deformation, a suitable Landau-Levich-Derjaguin-Bretherton analysis reveals that the lubrication film thickness h for large capsules depends on both the capillary number Ca and the capsule size a; our computations determine the latter dependence to be (in dimensionless form) h ~ a−2 for the large capsules studied in this work. For small and moderate capsule sizes a, the capsule velocity Ux and additional pressure drop ΔP+ are governed by the same scaling laws as for high-viscosity droplets. The velocity and additional pressure drop of large thick capsules also follow the dynamics of high-viscosity droplets, and are affected by the lubrication film thickness. The motion of our large thick capsules is characterized by a Ux−u~h~a−2 approach to the undisturbed average duct velocity and an additional pressure drop ΔP+ ~ a3/h ~ a5. By combining basic physical principles and geometric properties, we develop a theoretical analysis that explains the power laws we found for large capsules. PMID:21867212
Content based image retrieval using local binary pattern operator and data mining techniques.
Vatamanu, Oana Astrid; Frandeş, Mirela; Lungeanu, Diana; Mihalaş, Gheorghe-Ioan
2015-01-01
Content based image retrieval (CBIR) concerns the retrieval of similar images from image databases, using feature vectors extracted from images. These feature vectors globally define the visual content present in an image, defined by e.g., texture, colour, shape, and spatial relations between vectors. Herein, we propose the definition of feature vectors using the Local Binary Pattern (LBP) operator. A study was performed in order to determine the optimum LBP variant for the general definition of image feature vectors. The chosen LBP variant is then subsequently used to build an ultrasound image database, and a database with images obtained from Wireless Capsule Endoscopy. The image indexing process is optimized using data clustering techniques for images belonging to the same class. Finally, the proposed indexing method is compared to the classical indexing technique, which is nowadays widely used.
Meng, Yu; Lu, FangGen; Shi, Lin; Cheng, MeiChu; Zhang, Jie
2018-03-01
The use of anticoagulants is a contributor to gastrointestinal (GI) bleeding. Most bleeding patients on anticoagulant therapy such as warfarin commonly have basic lesions existing in their GI mucosa. We report a case of major GI bleeding following the use of anticoagulants in a patient with hookworm infection. The patient was diagnosed with nephrotic syndrome with pulmonary embolism. He was treated with anticoagulants and suffered from acute major GI bleeding during the treatment. Capsule endoscopy revealed many hookworms in the lumen of jejunum where fresh blood was seen coming from the mucosa. The patient was successfully rescued and cured with albendazole. Latent hookworm infection can be a cause of massive small-bowel hemorrhage in patients on anticoagulant therapy and anthelmintic treatment is the key to stop bleeding.
Identification of a functional capsule locus in Streptococcus mitis.
Rukke, H V; Hegna, I K; Petersen, F C
2012-04-01
The polysaccharide capsule of Streptococcus pneumoniae is a hallmark for virulence in humans. In its close relative Streptococcus mitis, a common human commensal, analysis of the sequenced genomes of six strains revealed the presence of a putative capsule locus in four of them. We constructed an isogenic S. mitis mutant from the type strain that lacked the 19 open reading frames in the capsule locus (Δcps mutant), using a deletion strategy similar to previous capsule functional studies in S. pneumoniae. Transmission electron microscopy and atomic force microscopy revealed a capsule-like structure in the S. mitis type strain that was absent or reduced in the Δcps mutant. Since S. mitis are predominant oral colonizers of tooth surfaces, we addressed the relevance of the capsule locus for the S. mitis overall surface properties, autoaggregation and biofilm formation. The capsule deletion resulted in a mutant with approximately two-fold increase in hydrophobicity. Binding to the Stains-all cationic dye was reduced by 40%, suggesting a reduction in the overall negative surface charge of the mutant. The mutant exhibited also increased autoaggregation in coaggregation buffer, and up to six-fold increase in biofilm levels. The results suggested that the capsule locus is associated with production of a capsule-like structure in S. mitis and indicated that the S. mitis capsule-like structure may confer surface attributes similar to those associated with the capsule in S. pneumoniae. © 2011 John Wiley & Sons A/S.
Diagnosis and management of Crohn's disease.
Wilkins, Thad; Jarvis, Kathryn; Patel, Jigneshkumar
2011-12-15
Crohn's disease is a chronic inflammatory condition affecting the gastrointestinal tract at any point from the mouth to the rectum. Patients may experience diarrhea, abdominal pain, fever, weight loss, abdominal masses, and anemia. Extraintestinal manifestations of Crohn's disease include osteoporosis, inflammatory arthropathies, scleritis, nephrolithiasis, cholelithiasis, and erythema nodosum. Acute phase reactants, such as C-reactive protein level and erythrocyte sedimentation rate, are often increased with inflammation and may correlate with disease activity. Levels of vitamin B12, folate, albumin, prealbumin, and vitamin D can help assess nutritional status. Colonoscopy with ileoscopy, capsule endoscopy, computed tomography enterography, and small bowel follow-through are often used to diagnose Crohn's disease. Ultrasonography, computed axial tomography, scintigraphy, and magnetic resonance imaging can assess for extraintestinal manifestations or complications (e.g., abscess, perforation). Mesalamine products are often used for the medical management of mild to moderate colonic Crohn's disease. Antibiotics (e.g., metronidazole, fluoroquinolones) are often used for treatment. Patients with moderate to severe Crohn's disease are treated with corticosteroids, azathioprine, 6-mercaptopurine, or anti-tumor necrosis factor agents (e.g., infliximab, adalimumab). Severe disease may require emergent hospitalization and a multidisciplinary approach with a family physician, gastroenterologist, and surgeon.
Update on imaging of Peutz-Jeghers syndrome
Tomas, Catherine; Soyer, Philippe; Dohan, Anthony; Dray, Xavier; Boudiaf, Mourad; Hoeffel, Christine
2014-01-01
Peutz-Jeghers syndrome (PJS) is a rare, autosomal dominant disease linked to a mutation of the STK 11 gene and is characterized by the development of benign hamartomatous polyps in the gastrointestinal tract in association with a hyperpigmentation on the lips and oral mucosa. Patients affected by PJS have an increased risk of developing gastrointestinal and extra-digestive cancer. Malignancy most commonly occurs in the small-bowel. Extra-intestinal malignancies are mostly breast cancer and gynecological tumors or, to a lesser extent, pancreatic cancer. These polyps are also at risk of acute gastrointestinal bleeding, intussusception and bowel obstruction. Recent guidelines recommend regular small-bowel surveillance to reduce these risks associated with PJS. Small-bowel surveillance allows for the detection of large polyps and the further referral of selected PJS patients for endoscopic enteroscopy or surgery. Video capsule endoscopy, double balloon pushed enteroscopy, multidetector computed tomography and magnetic resonance enteroclysis or enterography, all of which are relatively new techniques, have an important role in the management of patients suffering from PJS. This review illustrates the pathological, clinical and imaging features of small-bowel abnormalities as well as the role and performance of the most recent imaging modalities for the detection and follow-up of PJS patients. PMID:25152588
Pérez-Mendoza, A; Zárate-Guzmán, Á M; Galvis García, E S; Sobrino Cossío, S; Djamus Birch, J
Gastric cancer is one of the main causes of cancer worldwide, but there is currently no global screening strategy for the disease. Endoscopy is the screening method of choice in some Asian countries, but no standardized technique has been recognized. Systematic alphanumeric-coded endoscopy can increase gastric lesion detection. The aim of the present article was to compare the usefulness of systematic alphanumeric-coded endoscopy with conventional endoscopy for the detection of premalignant lesions and early gastric cancer in subjects at average risk for gastric cancer. A cross-sectional, comparative, prospective, randomized study was conducted on patients at average risk for gastric cancer (40-50 years of age, no history of H. pylori infection, intestinal metaplasia, gastric atrophy, or gastrointestinal surgery). Before undergoing endoscopy, the patients had gastric preparation (200mg of oral acetylcysteine or 50mg of oral dimethicone). Conventional chromoendoscopy was performed with indigo carmine dye for contrast enhancement. Fifty consecutive cases (mean age 44.4 ± 3.34 years, 60% women, BMI 27.6 ± 5.82 kg/m 2 ) were evaluated. Endoscopic imaging quality was satisfactory in all the cases, with no differences between methods (p = 0.817). The detection rate of premalignant lesions and early gastric cancer was 14% (6 cases of intestinal metaplasia and one case of gastric adenocarcinoma). Sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 100, 95, 80, 100 and 96%, respectively, for systematic alphanumeric-coded endoscopy, and 100, 45, 20, 100, and 52%, respectively, for conventional endoscopy. Lesion detection through systematic alphanumeric-coded endoscopy was superior to that of conventional endoscopy (p = 0.003; OR = 12). Both techniques were effective, but systematic alphanumeric-coded endoscopy significantly reduced the false positive rate. Copyright © 2018 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.
Jouhourian, Caroline; Bonis, Peter A; Guelrud, Moises
2016-05-01
Schatzki rings are found in the distal esophagus, are associated with hiatal hernias, and present with intermittent dysphagia to solid foods. They can be identified by radiology (GI series or barium swallow studies) or endoscopy. Rings are not always visualized during endoscopy in patients in whom they are suspected clinically. The Bolster technique involves application of epigastric abdominal pressure, which offers the potential to reveal a Schatzki ring that is otherwise obscured within a reduced hiatal hernia. The aim of this study was to determine whether the Bolster technique improves endoscopic detection of Schatzki rings. We reviewed 30 symptomatic patients with a history of a Schatzki ring in a tertiary care center. The Bolster technique was applied to patients in whom the ring was not visible during standard endoscopy. The main outcome measurement was identification of the Schatzki ring after the Bolster technique. A Schatzki ring was visible during standard endoscopy in 26 of the 30 patients. In the remaining 4, the ring was visible only after the application of the Bolster technique. The Bolster technique is a simple maneuver that can increase detection rates of Schatzki rings during endoscopy. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Sebastián Domingo, Juan José; Sánchez Sánchez, Clara; Galve Royo, Eugenio; Mendi Metola, Carolina; Valdepérez Torrubia, Javier
2012-02-01
To create an improvement team within a healthcare quality improvement project of the Government of Aragon (Spain), aimed at increasing the quality of care and suitability of the indications of gastrointestinal endoscopy in the open access endoscopy system of a secondary hospital in Aragon. The team developed a consensus document indicating how to use oral endoscopy and colonoscopy correctly, and held information and training sessions with all the primary care physicians involved in this area. Sector I health centers and Royo Villanova Hospital, in Zaragoza. The team consisted of a gastroenterologist and three primary care physicians and, from the outset received the support of the primary care administration and management in the health area. Inappropriate use of endoscopy, particularly colonoscopy, was reduced from 20% to 11.6%. Significant savings were achieved in health costs. The endoscopy waiting list was reduced. The quality of care and the safety of patients undergoing these examinations improved. Training of primary care physicians in these procedures was enhanced, and coordination between primary and specialized was implemented. To ensure efficient running of an open access gastrointestinal endoscopy system, an interdisciplinary improvement team and the full involvement of the primary care staff managing this resource are required. Copyright © 2011 Elsevier España, S.L. All rights reserved.
Haines, Brian M.; Yi, S. A.; Olson, R. E.; ...
2017-07-10
The wetted foam capsule design for inertial confinement fusion capsules, which includes a foam layer wetted with deuterium-tritium liquid, enables layered capsule implosions with a wide range of hot-spot convergence ratios (CR) on the National Ignition Facility. In this paper, we present a full-scale wetted foam capsule design that demonstrates high gain in one-dimensional simulations. In these simulations, increasing the convergence ratio leads to an improved capsule yield due to higher hot-spot temperatures and increased fuel areal density. High-resolution two-dimensional simulations of this design are presented with detailed and well resolved models for the capsule fill tube, support tent, surfacemore » roughness, and predicted asymmetries in the x-ray drive. Our modeling of these asymmetries is validated by comparisons with available experimental data. In 2D simulations of the full-scale wetted foam capsule design, jetting caused by the fill tube is prevented by the expansion of the tungsten-doped shell layer due to preheat. While the impacts of surface roughness and predicted asymmetries in the x-ray drive are enhanced by convergence effects, likely underpredicted in 2D at high CR, simulations predict that the capsule is robust to these features. Nevertheless, the design is highly susceptible to the effects of the capsule support tent, which negates all of the one-dimensional benefits of increasing the convergence ratio. Indeed, when the support tent is included in simulations, the yield decreases as the convergence ratio is increased for CR > 20. Finally and nevertheless, the results suggest that the full-scale wetted foam design has the potential to outperform ice layer capsules given currently achievable levels of asymmetries when fielded at low convergence ratios (CR < 20).« less
NASA Astrophysics Data System (ADS)
Haines, Brian M.; Yi, S. A.; Olson, R. E.; Khan, S. F.; Kyrala, G. A.; Zylstra, A. B.; Bradley, P. A.; Peterson, R. R.; Kline, J. L.; Leeper, R. J.; Shah, R. C.
2017-07-01
The wetted foam capsule design for inertial confinement fusion capsules, which includes a foam layer wetted with deuterium-tritium liquid, enables layered capsule implosions with a wide range of hot-spot convergence ratios (CR) on the National Ignition Facility. We present a full-scale wetted foam capsule design that demonstrates high gain in one-dimensional simulations. In these simulations, increasing the convergence ratio leads to an improved capsule yield due to higher hot-spot temperatures and increased fuel areal density. High-resolution two-dimensional simulations of this design are presented with detailed and well resolved models for the capsule fill tube, support tent, surface roughness, and predicted asymmetries in the x-ray drive. Our modeling of these asymmetries is validated by comparisons with available experimental data. In 2D simulations of the full-scale wetted foam capsule design, jetting caused by the fill tube is prevented by the expansion of the tungsten-doped shell layer due to preheat. While the impacts of surface roughness and predicted asymmetries in the x-ray drive are enhanced by convergence effects, likely underpredicted in 2D at high CR, simulations predict that the capsule is robust to these features. Nevertheless, the design is highly susceptible to the effects of the capsule support tent, which negates all of the one-dimensional benefits of increasing the convergence ratio. Indeed, when the support tent is included in simulations, the yield decreases as the convergence ratio is increased for CR > 20. Nevertheless, the results suggest that the full-scale wetted foam design has the potential to outperform ice layer capsules given currently achievable levels of asymmetries when fielded at low convergence ratios (CR < 20).
The Past, Present, and Future of Image-Enhanced Endoscopy
Jang, Jae-Young
2015-01-01
Despite the remarkable progress recently made to enhance the resolution of white-light endoscopy, detection, and diagnosis of premalignant lesions, such as adenomas and subtle early-stage cancers, remains a great challenge. As for example, although chromoendoscopy, such as endoscopy using indigo carmine, is useful for the early diagnosis of subtle lesions, the technique presents various disadvantages ranging from the time required for spray application of the dye and suctioning of excess dye to the increased difficulty in identifying lesions in the presence of severe inflammation and obstruction of visual field due to the pooling of solution in depressed-type lesions. To overcome these diagnostic problems associated with chromoendoscopy, research has focused on the development of endoscopes based on new optical technologies. Several types of image-enhanced endoscopy methods have recently been presented. In particular, image-enhanced endoscopy has emerged as a new paradigm for the diagnosis of gastrointestinal disorders. Image-enhanced endoscopes provide high-contrast images of lesions by means of optical or electronic technologies, including the contrast enhancement of the mucosal surface and of blood vessels. Chromoendoscopy, narrow-band imaging, i-SCAN, and flexible spectral imaging color enhancement are representative examples of image-enhanced endoscopy discussed in this paper. PMID:26668791
[Premalignant conditions of the small bowel].
Drastich, P
2013-01-01
Small intestinal dysplastic lesions are rare and difficult to detect before they progress to cancer. New investigative modalities, such as capsule endoscopy and doubleballoon enteroscopy, are very promising in search for premalignant lesions. Screening patients at high-risk for small bowel neoplasia is the only sensible approach. Duodenal adenoma represents the most easily accessible tumors with the possibility of curative endoscopic resection. Due to the strong association of the small bowel and colonic adenomas, it is always necessary to perform colonoscopy. In young patients, the exclusion of familial polyposis by genetic testing is always mandatory. Patients with celiac disease are especially at risk of developing nonHodgkins lymphomas and adenocarcinomas. There is a high-risk of ampuloma and other adenomas in patients with familial adenomatous polyposis. Patients with prolonged and complicated course of Crohns disease, Peutz Jeghers syndrome and patients with ileoanal pouch have higher risk of adenocarcinoma of the small intestine.
[Congenital intestinal lymphangiectasia].
Popović, Dugan D j; Spuran, Milan; Alempijević, Tamara; Krstić, Miodrag; Djuranović, Srdjan; Kovacević, Nada; Damnjanović, Svetozar; Micev, Marjan
2011-03-01
Congenital intestinal lymphangiectasia is a disease which leads to protein losing enteropathy. Tortuous, dilated lymphatic vessels in the intestinal wall and mesenterium are typical features of the disease. Clinical manifestations include malabsorption, diarrhea, steatorrhea, edema and effusions. Specific diet and medication are required for disease control. A 19-year old male patient was hospitalized due to diarrhea, abdominal swelling, weariness and fatigue. Physical examination revealed growth impairment, ascites, and lymphedema of the right hand and forearm. Laboratory assessment indicated iron deficiency anaemia, lymphopenia, malabsorption, inflammatory syndrome, and urinary infection. Enteroscopy and video capsule endoscopy demonstrated dilated lymphatic vessels in the small intestine. The diagnosis was confirmed by intestinal biopsy. The patient was put on high-protein diet containing medium-chain fatty acids, somatotropin and supportive therapy. Congenital intestinal lymphangiectasia is a rare disease, usually diagnosed in childhood. Early recognition of the disease and adequate treatment can prevent development of various complications.
Ueki, Masaru; Uehara, Kazutake; Isomoto, Hajime
2018-05-15
In recent years, there has been a growing need for skills quantification of endoscopic specialist. Various educational simulators have been created to help increase the endoscopy performance of medical students and trainees. Recent research seems to show that the use of simulators helps increase the skill level of endoscopists, while improving patient safety 1, 2 . However, previous simulators lack sufficient realism and are unable to replicate natural human reactions during endoscopy or quantify endoscopic skills. We developed a novel humanoid-robot simulator (named mikoto ® ) with pharyngeal reflexes and real-life responses to endoscopy. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Yao, Hsuan-Ming; Hsu, Ann; Gupta, Suneel; Modi, Nishit B.
2016-01-01
Objectives IPX066 is an oral, extended-release capsule formulation of carbidopa-levodopa (CD-LD) available in 4 strengths. The goals of this investigation were to assess the dose proportionality of IPX066 and to study the effects of a high-fat, high-calorie meal and of sprinkling the capsule contents on applesauce on the pharmacokinetics of IPX066 in healthy volunteers. Methods Three open-label studies were conducted. In the first study, subjects received 1 capsule of each IPX066 strength (23.75–95, 36.25–145, 48.75–195, and 61.25–245 mg of CD-LD). In the second study, subjects received 1 and 2 capsules of IPX066 245-mg LD under fasting conditions. In the third study, subjects received 2 capsules of IPX066 245-mg LD under 3 conditions: fasting; following a high-fat, high-calorie breakfast; and with the capsule contents sprinkled on applesauce under fasting conditions. Results Peak plasma concentrations (Cmax) and systemic exposure (AUCt, AUCinf) for LD and CD increased dose-proportionally over the range of the IPX066 capsule strengths. Comparison of 1 and 2 IPX066 245-mg LD capsules showed dose-proportional pharmacokinetics for Cmax and AUCt. Sprinkling the capsule contents on applesauce did not affect the pharmacokinetics. A high-fat, high-calorie meal delayed the initial increase in LD concentration by approximately 1 to 2 hours, reduced Cmax by 21%, and increased AUCinf by 13% compared with the fasted state. Conclusions IPX066 shows dose-proportional pharmacokinetics. Sprinkling the capsule contents on applesauce does not affect the pharmacokinetics; a high-fat, high-calorie meal delayed absorption by 1 to 2 hours, slightly reduced Cmax, and slightly increased extent of absorption. PMID:26626430
Yao, Hsuan-Ming; Hsu, Ann; Gupta, Suneel; Modi, Nishit B
2016-01-01
IPX066 is an oral, extended-release capsule formulation of carbidopa-levodopa (CD-LD) available in 4 strengths. The goals of this investigation were to assess the dose proportionality of IPX066 and to study the effects of a high-fat, high-calorie meal and of sprinkling the capsule contents on applesauce on the pharmacokinetics of IPX066 in healthy volunteers. Three open-label studies were conducted. In the first study, subjects received 1 capsule of each IPX066 strength (23.75-95, 36.25-145, 48.75-195, and 61.25-245 mg of CD-LD). In the second study, subjects received 1 and 2 capsules of IPX066 245-mg LD under fasting conditions. In the third study, subjects received 2 capsules of IPX066 245-mg LD under 3 conditions: fasting; following a high-fat, high-calorie breakfast; and with the capsule contents sprinkled on applesauce under fasting conditions. Peak plasma concentrations (Cmax) and systemic exposure (AUCt, AUCinf) for LD and CD increased dose-proportionally over the range of the IPX066 capsule strengths. Comparison of 1 and 2 IPX066 245-mg LD capsules showed dose-proportional pharmacokinetics for Cmax and AUCt. Sprinkling the capsule contents on applesauce did not affect the pharmacokinetics. A high-fat, high-calorie meal delayed the initial increase in LD concentration by approximately 1 to 2 hours, reduced Cmax by 21%, and increased AUCinf by 13% compared with the fasted state. IPX066 shows dose-proportional pharmacokinetics. Sprinkling the capsule contents on applesauce does not affect the pharmacokinetics; a high-fat, high-calorie meal delayed absorption by 1 to 2 hours, slightly reduced Cmax, and slightly increased extent of absorption.
Primate lens capsule elasticity assessed using Atomic Force Microscopy
Ziebarth, Noël M.; Arrieta, Esdras; Feuer, William J.; Moy, Vincent T.; Manns, Fabrice; Parel, Jean-Marie
2011-01-01
The purpose of this project is to measure the elasticity of the human and non-human primate lens capsule at the microscopic scale using Atomic Force Microscopy (AFM). Elasticity measurements were performed using AFM on the excised anterior lens capsule from 9 cynomolgus monkey (5.9–8.0 years), 8 hamadryas baboon (2.8–10.1 years), and 18 human lenses (33–79 years). Anterior capsule specimens were obtained by performing a 5mm continuous curvilinear capsulorhexis and collecting the resulting disk of capsular tissue. To remove the lens epithelial cells the specimen was soaked in 0.1% trypsin and 0.02% EDTA for five minutes, washed, and placed on a Petri dish and immersed in DMEM. Elasticity measurements of the capsule were performed with a laboratory-built AFM system custom designed for force measurements of ophthalmic tissues. The capsular specimens were probed with an AFM cantilever tip to produce force-indentation curves for each specimen. Young’s modulus was calculated from the force-indentation curves using the model of Sneddon for a conical indenter. Young’s modulus of elasticity was 20.1–131kPa for the human lens capsule, 9.19–117kPa for the cynomolgus lens capsule, and 13.1–62.4kPa for the baboon lens capsule. Young’s modulus increased significantly with age in humans (p=0.03). The age range of the monkey and baboon samples was not sufficient to justify an analysis of age dependence. The capsule elasticity of young humans (<45 years) was not statistically different from that of the monkey and baboon. In humans, there is an increase in lens capsule stiffness at the microscale that could be responsible for an increase in lens capsule bulk stiffness. PMID:21420953
Rukke, H V; Engen, S A; Schenck, K; Petersen, F C
2016-08-01
Streptococcus mitis is a colonizer of the oral cavity and the nasopharynx, and is closely related to Streptococcus pneumoniae. Both species occur in encapsulated and unencapsulated forms, but in S. mitis the role of the capsule in host interactions is mostly unknown. Therefore, the aim of this study was to examine how capsule expression in S. mitis can modulate interactions with the host with relevance for colonization. The S. mitis type strain, as well as two mutants of the type strain, an isogenic capsule deletion mutant, and a capsule switch mutant expressing the serotype 4 capsule of S. pneumoniae TIGR4, were used. Wild-type and capsule deletion strains of S. pneumoniae TIGR4 were included for comparison. We found that capsule production in S. mitis reduced adhesion to oral and lung epithelial cells. Further, exposure of oral epithelial cells to encapsulated S. mitis resulted in higher interleukin-6 and CXCL-8 transcription levels relative to the unencapsulated mutant. Capsule expression in S. mitis increased the sensitivity to human neutrophil peptide 1-3 but reduced the sensitivity to human β-defensin-3 and cathelicidin. This was in contrast with S. pneumoniae in which capsule expression has been generally associated with increased sensitivity to human antimicrobial peptides (AMPs). Collectively, these findings indicate that capsule expression in S. mitis is important in modulating interactions with epithelial cells, and is associated with increased or reduced susceptibility to AMPs depending on the nature of the AMP. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
In situ encapsulation of liquids by means of crystallization
NASA Astrophysics Data System (ADS)
Hartwig, Anne; Ulrich, Joachim
2017-07-01
The in situ encapsulation process is due to its few process steps an innovative and cost effective alternative to common encapsulation techniques. It combines the well-known processes of pastillation and crystallization. This concept is proven with case studies of three xylitol capsules which vary in composition and size. It could be shown that the knowledge concerning the solubility of the components is essential to determine the suitable production conditions. The application of seed crystals and the temperatures during the process have major effects on the capsules quality. A fast crystallization of the capsules results in an instable shell. However, with increasing layer thickness of the shell, the crushing force that needs to be applied to break the capsules is increasing as well. But the stability which is related to the capsules size is decreasing with increasing diameter, even though layer thickness and crushing force are increasing, too.
Al-Tabakha, Moawia M; Arida, Adi Issam; Fahelelbom, Khairi M S; Sadek, Bassem; Saeed, Dima Ahmed; Abu Jarad, Rami A; Jawadi, Jeevani
2015-01-01
The purpose of this study was to assess the in vitro performances of "vegetable" capsules in comparison to hard gelatin capsules in terms of shell weight variation, reaction to different humidity conditions, resistance to stress in the absence of moisture, powder leakage, disintegration and dissolution. Two types of capsules made of HPMC produced with (Capsule 2) or without (Capsule 3) a gelling agent and hard gelatin capsules (Capsule 1) were assessed. Shell weight variability was relatively low for all tested capsules shells. Although Capsule 1 had the highest moisture content under different humidity conditions, all capsule types were unable to protect the encapsulated hygroscopic polyvinylpyrrolidone (PVP) powder from surrounding humidity. The initial disintegration for all Capsule 1 occurred within 3 min, but for other types of capsules within 6 min (n = 18). Dissolution of acetaminophen was better when the deionized water (DIW) temperature increased from 32 to 42 °C in case of Capsule 1, but the effect of temperature was not significant for the other types of capsules. Acetaminphen dissolution from Capsule 1 was the fastest (i.e. >90% in 10 min) and independent of the media pH or contents unlike Capsule 2 which was influenced by the pH and dissolution medium contents. It is feasible to use hypromellose capsules shells with or without gelling agent for new lines of pharmaceutical products, however, there is a window for capsule shells manufacturing companies to improve the dissolution of their hypromellose capsules to match the conventional gelatin capsule shells and eventually replace them.
Computed Tomography Evaluation of Esophagogastric Necrosis After Caustic Ingestion.
Chirica, Mircea; Resche-Rigon, Matthieu; Zagdanski, Anne Marie; Bruzzi, Matthieu; Bouda, Damien; Roland, Eric; Sabatier, François; Bouhidel, Fatiha; Bonnet, Francine; Munoz-Bongrand, Nicolas; Marc Gornet, Jean; Sarfati, Emile; Cattan, Pierre
2016-07-01
Endoscopy is the standard of care for emergency patient evaluation after caustic ingestion. However, the inaccuracy of endoscopy in determining the depth of intramural necrosis may lead to inappropriate decision-making with devastating consequences. Our aim was to evaluate the use of computed tomography (CT) for the emergency diagnostic workup of patients with caustic injuries. In a prospective study, we used a combined endoscopy-CT decision-making algorithm. The primary outcome was pathology-confirmed digestive necrosis. The respective utility of CT and endoscopy in the decision-making process were compared. Transmural endoscopic necrosis was defined as grade 3b injuries; signs of transmural CT necrosis included absence of postcontrast gastric/ esophageal-wall enhancement, esophageal-wall blurring, and periesophageal-fat blurring. We included 120 patients (59 men, median age 44 years). Emergency surgery was performed in 24 patients (20%) and digestive resection was completed in 16. Three patients (3%) died and 28 patients (23%) experienced complications. Pathology revealed transmural necrosis in 9/11 esophagectomy and 16/16 gastrectomy specimens. Severe oropharyngeal injuries (P = 0.015), increased levels of blood lactate (P = 0.007), alanine aminotransferase (P = 0.027), bilirubin (P = 0.005), and low platelet counts (P > 0.0001) were predictive of digestive necrosis. Decision-making relying on CT alone or on a combined CT-endoscopy algorithm was similar and would have spared 19 unnecessary esophagectomies and 16 explorative laparotomies compared with an endoscopy-alone algorithm. Endoscopy did never rectify a wrong CT decision. Emergency decision-making after caustic injuries can rely on CT alone.
Beaulieu, C F; Jeffrey, R B; Karadi, C; Paik, D S; Napel, S
1999-07-01
To determine the sensitivity of radiologist observers for detecting colonic polyps by using three different data review (display) modes for computed tomographic (CT) colonography, or "virtual colonoscopy." CT colonographic data in a patient with a normal colon were used as base data for insertion of digitally synthesized polyps. Forty such polyps (3.5, 5, 7, and 10 mm in diameter) were randomly inserted in four copies of the base data. Axial CT studies, volume-rendered virtual endoscopic movies, and studies from a three-dimensional mode termed "panoramic endoscopy" were reviewed blindly and independently by two radiologists. Detection improved with increasing polyp size. Trends in sensitivity were dependent on whether all inserted lesions or only visible lesions were considered, because modes differed in how completely the colonic surface was depicted. For both reviewers and all polyps 7 mm or larger, panoramic endoscopy resulted in significantly greater sensitivity (90%) than did virtual endoscopy (68%, P = .014). For visible lesions only, the sensitivities were 85%, 81%, and 60% for one reader and 65%, 62%, and 28% for the other for virtual endoscopy, panoramic endoscopy, and axial CT, respectively. Three-dimensional displays were more sensitive than two-dimensional displays (P < .05). The sensitivity of panoramic endoscopy is higher than that of virtual endoscopy, because the former displays more of the colonic surface. Higher sensitivities for three-dimensional displays may justify the additional computation and review time.
Schulman, Allison R; Chan, Walter W; Devery, Aiofe; Ryan, Michele B; Thompson, Christopher C
2017-04-01
Marginal ulceration, or ulceration at the gastrojejunal anastomosis, is a common complication of Roux-en-Y gastric bypass (RYGB). Acidity likely contributes to the pathophysiology, and proton pump inhibitors (PPIs) frequently are prescribed for treatment. However, patients with gastric bypass only have a small gastric pouch and rapid small-bowel transit, which limits the opportunity for capsule breakdown and PPI absorption. Soluble PPIs (open capsules [OCs]) might be absorbed more easily than intact capsules (ICs). We compared time to ulcer healing, number of endoscopic procedures, and use of health care for patients with marginal ulceration who received PPIs in OC vs IC form. We performed a retrospective study of 164 patients diagnosed with marginal ulceration who underwent RYGB at the Brigham and Women's Hospital from 2000 through 2015. Patients received high-dose PPIs and underwent repeat endoscopy every 3 months until ulcer healing was confirmed. We used time-to-event analysis with a Cox proportional hazards model to evaluate the association between mode of PPI administration and time to ulcer healing, in addition to Cox multivariate regression analysis. Total charge (procedural and maintenance) was determined by comparison of categorized charges incurred from time of ulcer diagnosis to resolution. The primary outcome was time to healing of marginal ulceration in RYGB patients receiving high-dose PPIs in OC vs IC form. A total of 162 patients were included (115 received OC and 49 received IC). All patients were followed up until ulcer healing was confirmed. The median time to ulcer healing was 91.0 days for the OC group vs 342.0 days for the IC group (P < .001). OC was the only independent predictor of time to ulcer healing (P < .001) when we controlled for known risk factors. The number of endoscopic procedures (P = .02) and overall health care utilization (P = .05) were lower in the OC than the IC group. Patients with marginal ulceration after RYGB who receive OC PPIs have shorter ulcer healing times, fewer endoscopic procedures, and use less health care resources compared with patients who receive IC PPIs. Given these results and the high prevalence of marginal ulceration in this patient population, the use of OC PPIs is a low-risk, low-cost alternative that should be considered. Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.
Marchenko, Irina; Yashchenok, Alexey; Borodina, Tatiana; Bukreeva, Tatiana; Konrad, Manfred; Möhwald, Helmuth; Skirtach, Andre
2012-09-28
Enzyme-catalyzed degradation of CaCO₃-templated capsules is presented. We investigate a) biodegradable, b) mixed biodegradable/synthetic, and c) multicompartment polyelectrolyte multilayer capsules with different numbers of polymer layers. Using confocal laser scanning microscopy we observed the kinetics of the non-specific protease Pronase-induced degradation of capsules is slowed down on the order of hours by either increasing the number of layers in the wall of biodegradable capsules, or by inserting synthetic polyelectrolyte multilayers into the shell comprised of biodegradable polymers. The degradation rate increases with the concentration of Pronase. Controlled detachment of subcompartments of multicompartment capsules, with potential for intracellular delivery or in-vivo applications, is also shown. Copyright © 2012 Elsevier B.V. All rights reserved.
The role of a nurse telephone call to prevent no-shows in endoscopy.
Childers, Ryan E; Laird, Amy; Newman, Lisa; Keyashian, Kian
2016-12-01
Preventing missed appointments, or "no-shows," is an important target in improving efficient patient care and lowering costs in gastrointestinal endoscopy practices. We aimed to investigate whether a nurse telephone call would reduce no-show rates for endoscopic appointments, and to determine if hiring and maintaining a nurse dedicated to pre-endoscopy phone calls is economically advantageous. Our secondary aim was to identify predictors of no-shows to endoscopy appointments. We hired and trained a full-time licensed nurse to make a telephone call to patients 7 days before their scheduled upper endoscopy or colonoscopy. We compared this intervention with a previous reminder system involving mailed reminders. The effect of the intervention and impact of other predictors of no-shows were analyzed in 2 similar preintervention and postintervention patient cohorts. A mixed effects logistic regression model was used to estimate the association of the odds of being a no-show to the scheduled appointment and the characteristics of the patient and visit. An analysis of costs was performed that included the startup and maintenance costs of the intervention. We found that a nurse phone call was associated with a 33% reduction in the odds of a no-show visit (odds ratio, 0.67; 95% confidence interval, 0.50-0.91), adjusting for gender, age, partnered status, insurer type, distance from the endoscopy center, and visit type. The recovered reimbursement during the study period was $48,765, with net savings of $16,190 when accounting for the maintenance costs of the intervention; this resulted in a net revenue per annum of $43,173. We found that endoscopy practices may increase revenue, improve scheduling efficiency, and maximize resource utilization by hiring a nurse to reduce no-shows. Predictors of no-shows to endoscopy included unpartnered or single patients, commercial or managed care, being scheduled for colonoscopy as opposed to upper endoscopy, and being scheduled for a screening or surveillance colonoscopy. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Hydes, Theresa; Hansi, Navjyot; Trebble, Timothy M
2012-01-01
Upper gastrointestinal (UGI) endoscopy is a routine healthcare procedure with a defined patient pathway. The objective of this study was to redesign this pathway for unsedated patients using lean thinking transformation to focus on patient-derived value-adding steps, remove waste and create a more efficient process. This was to form the basis of a pathway template that was transferrable to other endoscopy units. A literature search of patient expectations for UGI endoscopy identified patient-derived value. A value stream map was created of the current pathway. The minimum and maximum time per step, bottlenecks and staff-staff interactions were recorded. This information was used for service transformation using lean thinking. A patient pathway template was created and implemented into a secondary unit. Questionnaire studies were performed to assess patient satisfaction. In the primary unit the patient pathway reduced from 19 to 11 steps with a reduction in the maximum lead time from 375 to 80 min following lean thinking transformation. The minimum value/lead time ratio increased from 24% to 49%. The patient pathway was redesigned as a 'cellular' system with minimised patient and staff travelling distances, waiting times, paperwork and handoffs. Nursing staff requirements reduced by 25%. Patient-prioritised aspects of care were emphasised with increased patient-endoscopist interaction time. The template was successfully introduced into a second unit with an overall positive patient satisfaction rating of 95%. Lean thinking transformation of the unsedated UGI endoscopy pathway results in reduced waiting times, reduced staffing requirements and improved patient flow and can form the basis of a pathway template which may be successfully transferred into alternative endoscopy environments with high levels of patient satisfaction.
Thermoregulation of Capsule Production by Streptococcus pyogenes
Kang, Song Ok; Wright, Jordan O.; Tesorero, Rafael A.; Lee, Hyunwoo; Beall, Bernard; Cho, Kyu Hong
2012-01-01
The capsule of Streptococcus pyogenes serves as an adhesin as well as an anti-phagocytic factor by binding to CD44 on keratinocytes of the pharyngeal mucosa and the skin, the main entry sites of the pathogen. We discovered that S. pyogenes HSC5 and MGAS315 strains are further thermoregulated for capsule production at a post-transcriptional level in addition to the transcriptional regulation by the CovRS two-component regulatory system. When the transcription of the hasABC capsular biosynthetic locus was de-repressed through mutation of the covRS system, the two strains, which have been used for pathogenesis studies in the laboratory, exhibited markedly increased capsule production at sub-body temperature. Employing transposon mutagenesis, we found that CvfA, a previously identified membrane-associated endoribonuclease, is required for the thermoregulation of capsule synthesis. The mutation of the cvfA gene conferred increased capsule production regardless of temperature. However, the amount of the capsule transcript was not changed by the mutation, indicating that a post-transcriptional regulator mediates between CvfA and thermoregulated capsule production. When we tested naturally occurring invasive mucoid strains, a high percentage (11/53, 21%) of the strains exhibited thermoregulated capsule production. As expected, the mucoid phenotype of these strains at sub-body temperature was due to mutations within the chromosomal covRS genes. Capsule thermoregulation that exhibits high capsule production at lower temperatures that occur on the skin or mucosal surface potentially confers better capability of adhesion and invasion when S. pyogenes penetrates the epithelial surface. PMID:22615992
2012-01-01
Background Colorectal cancer (CRC) screening requires sufficient endoscopic resources. The present study aims to determine the Dutch endoscopic production and manpower for 2009, evaluate trends since 2004, determine additional workload which would be caused by implementation of a CRC screening program, and inventory colonoscopy rates performed in other European countries. Methods All Dutch endoscopy units (N = 101) were surveyed for manpower and the numbers of endoscopy procedures performed in 2009. Based on calculations in the report issued by the Dutch Health Council, future additional workload caused by faecal immunochemical test (FIT) screening was estimated. The number of colonoscopies performed in Europe was evaluated by a literature search and an email-inquiry. Results Compared to 2004, there was a 24% increase in total endoscopies (N = 505,226 in 2009), and a 64% increase in colonoscopies (N = 191,339 in 2009) in The Netherlands. The number of endoscopists had increased by 4.6% (N = 583 in 2009). Five years after stepwise implementation of FIT-based CRC screening, endoscopic capacity needs to be increased an additional 15%. A lack of published data on the number of endoscopies performed in Europe was found. Based on our email-inquiry, the number of colonoscopies per 100,000 inhabitants ranged from 126 to 3,031 in 15 European countries. Conclusions Over the last years, endoscopic procedures increased markedly in The Netherlands without a corresponding increase in manpower. A FIT-based CRC screening program requires an estimated additional 15% increase in endoscopic procedures. It is very likely that current colonoscopy density varies widely across European countries. PMID:22280408
48-hour wireless oesophageal pH-monitoring in children: are two days better than one?
Gunnarsdóttir, A; Stenström, P; Arnbjörnsson, E
2007-12-01
Use of a catheter-free, radio telemetric, oesophageal pH-monitoring system in paediatric clinical practice allows patients to follow a more normal physiological pattern of activities and causes less discomfort. At our institution, placement of the capsule is done under general anaesthesia, which restricts the child's activity during the first day. The aim of this study was to determine whether oesophageal pH-measurements should be performed over 48 hours or whether 24-hour measurement provides sufficient and reliable results. The study included 24 consecutive children with symptomatic gastro-oesophageal reflux problems who had undergone upper gastrointestinal endoscopies under general anaesthesia. The radio-transmitting Bravo capsule was introduced transorally and placed above the diaphragm at a width of two vertebral bodies. Oesophageal acid exposure was monitored via a portable receiver for 48 hours. The children's symptoms during measurements were registered. Wilcoxon signed rank test for paired samples was used after power analysis. The capsule was successfully attached to the oesophageal mucosa in all cases with minor technical problems in only one patient. The 48-hour pH-monitoring was completed in 23 patients. The median percentage time with an oesophageal pH of less than 4 was 5.4 +/- 6.8 for the first 24 hours and 5.8 +/- 7.4 for the 48-hour measurement. The DeMeester score was 20.5 +/- 23.7 and 22.2 +/- 25.7, respectively. Ambulatory pH-monitoring using the wireless system is feasible and safe. It was well-tolerated by the children. There was no statistical difference between the pH-measurements or DeMeester scores during the first 24 hours compared with the 48-hour measurements. Individual variations were noted but had no clinical significance except in two patients. Our results support the use of pH-measurement for a period of 24 hours only.
A blue optical filter for narrow-band imaging in endoscopic capsules
NASA Astrophysics Data System (ADS)
Silva, M. F.; Ghaderi, M.; Goncalves, L. M.; de Graaf, G.; Wolffenbuttel, R. F.; Correia, J. H.
2014-05-01
This paper presents the design, simulation, fabrication, and characterization of a thin-film Fabry-Perot resonator composed of titanium dioxide (TiO2) and silicon dioxide (SiO2) thin-films. The optical filter is developed to be integrated with a light emitting diode (LED) for enabling narrow-band imaging (NBI) in endoscopy. The NBI is a high resolution imaging technique that uses spectrally centered blue light (415 nm) and green light (540 nm) to illuminate the target tissue. The light at 415 nm enhances the imaging of superficial veins due to their hemoglobin absorption, while the light at 540 nm penetrates deeper into the mucosa, thus enhances the sub-epithelial vessels imaging. Typically the endoscopes and endoscopic capsules use white light for acquiring images of the gastrointestinal (GI) tract. However, implementing the NBI technique in endoscopic capsules enhances their capabilities for the clinical applications. A commercially available blue LED with a maximum peak intensity at 404 nm and Full Width Half Maximum (FWHM) of 20 nm is integrated with a narrow band blue filter as the NBI light source. The thin film simulations show a maximum spectral transmittance of 36 %, that is centered at 415 nm with FWHM of 13 nm for combined the blue LED and a Fabry Perot resonator system. A custom made deposition scheme was developed for the fabrication of the blue optical filter by RF sputtering. RF powered reactive sputtering at 200 W with the gas flows of argon and oxygen that are controlled for a 5:1 ratio gives the optimum optical conditions for TiO2 thin films. For SiO2 thin films, a non-reactive RF sputtering at 150 W with argon gas flow at 15 sccm results in the best optical performance. The TiO2 and SiO2 thin films were fully characterized by an ellipsometer in the wavelength range between 250 nm to 1600 nm. Finally, the optical performance of the blue optical filter is measured and presented.
Bang, Seungmin; Park, Jeong Youp; Jeong, Seok; Kim, Young Ho; Shim, Han Bo; Kim, Tae Song; Lee, Don Haeng; Song, Si Young
2009-02-01
We developed a capsule endoscope (CE), "MiRo," with the novel transmission technology of electric-field propagation. The technology uses the human body as a conductive medium for data transmission. Specifications of the prototype include the ability to receive real-time images; size, 10.8 x 24 mm; weight, 3.3 g; field of view, 150 degrees; resolution of power, 320 x 320 pixels; and transmittal speed, 2 frames per second. To evaluate the clinical safety and diagnostic feasibility of the prototype MiRo, we conducted a multicenter clinical trial. All volunteers underwent baseline examinations, including EGD and electrocardiography for the screening of GI obstructive and cardiovascular diseases, before the trial. In the first 10 cases, 24-hour Holter monitoring was also performed. To evaluate the diagnostic feasibility, transmission rate of the captured images, inspection rate of the entire small bowel, and quality of transmitted images (graded as outstanding, excellent, good/average, below average, and poor) were analyzed. Of the 49 healthy volunteers, 45 were included in the trial, and 4 were excluded because of baseline abnormalities. No adverse effects were noted. All CEs were expelled within 2 days, and the entire small bowel could be explored in all cases. The transmission rates of the captured image in the stomach, small bowel, and colon were 99.5%, 99.6%, and 97.2%, respectively. The mean total duration of image transmission was 9 hours, 51 minutes, and the mean transit time of the entire small bowel was 4 hours, 33 minutes. Image quality was graded as good or better in 41 cases (91.1%). Details of the villi and vascular structures of the entire small bowel were clearly visualized in 31 cases (68.9%). MiRo is safe and effective for exploring the entire small bowel, with good image quality and real-time feasibility. This novel transmission technology may have applications beyond the field of capsule endoscopy.
Angelova, N; Hunkeler, D
2001-01-01
Capsules were obtained by interpolymer complexation between chitosan (polycation) and sodium hexametaphosphate (SMP, oligoanion). The effect of the preparation conditions on the capsule characteristics was evaluated. Specifically, the influence of variables such as pH, ionic strength, reagent concentration, and additives on the capsule permeability properties was investigated using dextran as a model permeant. The capsule membrane permeability was found to increase by decreasing the chitosan/SMP ratio as well as adding mannitol to the oligoanion recipient bath. Increasing the ionic strength or the pH of the initial chitosan solution was also found to enhance the membrane permeability, moving the membrane exclusion limit to higher values. Generally, the capsules prepared tinder all tested conditions had a relatively low permeability which rarely exceeded a molecular cut-off of 40 kD based on dextran standards. Furthermore, the diffusion rate showed a strong temporal dependence, indicating that the capsules prepared under various conditions exhibit different apparent pore size densities on the surface. The results indicated that, in order to obtain the desired capsule mass-transfer properties, the preparation conditions should be carefully considered and adjusted. Adding a polyol as well as low salt amount (less than 0.15%) is preferable as a means of modulating the diffusion characteristics, without disturbing the capsule mechanical stability.
Behara, Srinivas R.B.; Farkas, Dale R.; Hindle, Michael; Longest, P. Worth
2013-01-01
Purpose The objective of this study was to explore the performance of a high efficiency dry powder inhaler (DPI) intended for excipient enhanced growth (EEG) aerosol delivery based on changes to the capsule orientation and surface modifications of the capsule and device. Methods DPIs were constructed by combining newly designed capsule chambers (CC) with a previously developed three-dimensional (3D) rod array for particle deagglomeration and a previously optimized EEG formulation. The new CCs oriented the capsule perpendicular to the incoming airflow and were analyzed for different air inlets at a constant pressure drop across the device. Modifications to the inhaler and capsule surfaces included use of metal dispersion rods and surface coatings. Aerosolization performance of the new DPIs was evaluated and compared with commercial devices. Results The proposed capsule orientation and motion pattern increased capsule vibrational frequency and reduced the aerosol MMAD compared with commercial/modified DPIs. The use of metal rods in the 3D array further improved inhaler performance. Coating the inhaler and capsule with PTFE significantly increased emitted dose (ED) from the optimized DPI. Conclusions High efficiency performance is achieved for EEG delivery with the optimized DPI device and formulation combination producing an aerosol with MMAD < 1.5 µm, FPF<5µm/ED > 90%, and ED > 80%. PMID:23949304
Rampinelli, Vittorio; Doglietto, Francesco; Mattavelli, Davide; Qiu, Jimmy; Raffetti, Elena; Schreiber, Alberto; Villaret, Andrea Bolzoni; Kucharczyk, Walter; Donato, Francesco; Fontanella, Marco Maria; Nicolai, Piero
2017-09-01
Three-dimensional (3D) endoscopy has been recently introduced in endonasal skull base surgery. Only a relatively limited number of studies have compared it to 2-dimensional, high definition technology. The objective was to compare, in a preclinical setting for endonasal endoscopic surgery, the surgical maneuverability of 2-dimensional, high definition and 3D endoscopy. A group of 68 volunteers, novice and experienced surgeons, were asked to perform 2 tasks, namely simulating grasping and dissection surgical maneuvers, in a model of the nasal cavities. Time to complete the tasks was recorded. A questionnaire to investigate subjective feelings during tasks was filled by each participant. In 25 subjects, the surgeons' movements were continuously tracked by a magnetic-based neuronavigator coupled with dedicated software (ApproachViewer, part of GTx-UHN) and the recorded trajectories were analyzed by comparing jitter, sum of square differences, and funnel index. Total execution time was significantly lower with 3D technology (P < 0.05) in beginners and experts. Questionnaires showed that beginners preferred 3D endoscopy more frequently than experts. A minority (14%) of beginners experienced discomfort with 3D endoscopy. Analysis of jitter showed a trend toward increased effectiveness of surgical maneuvers with 3D endoscopy. Sum of square differences and funnel index analyses documented better values with 3D endoscopy in experts. In a preclinical setting for endonasal skull base surgery, 3D technology appears to confer an advantage in terms of time of execution and precision of surgical maneuvers. Copyright © 2017 Elsevier Inc. All rights reserved.
Minimally invasive functional approach for cholesteatoma surgery.
Hanna, Bassem M; Kivekäs, Ilkka; Wu, Yi-Hsuan; Guo, Lee J; Lin, Huang; Guidi, Jessica; Poe, Dennis
2014-10-01
Report the efficacy of a functional minimally invasive approach for cholesteatoma surgery. Retrospective review of surgical cases performed between 1996 and 2008. One hundred sixty-nine patient charts were reviewed in which ears with primary cholesteatomas that extended beyond the mesotympanum were operated on with a plan for canal wall up (CWU) mastoidectomy. The surgical approach consisted of progressive exposure from transcanal to postauricular tympanoplasty to CWU mastoidectomy, as needed, to identify and lyse the fibrous attachments that bind the capsule to the surrounding mucosa. Endoscopic guidance was employed as appropriate to minimize exposure needs. Any planned second-stage operations were attempted with a transcanal approach if appropriate and with endoscopic assistance. One hundred eighty-four ears of 169 patients were included. The median age was 32 years (range, 1-79 years). The mean follow-up was 3.2 years (range, 1-11 years). Eighty-three (45%) were planned for a second-look operation, and three (2%) required unplanned second operations. The overall recurrence rate was 24/184 (13%), and the unexpected residual rate was 5/184 (3%). The residual rate with endoscopy (5/119, 4%,) or without endoscopy (1/65, 2%), were not significantly different. Hearing results in 156 ears improved significantly, from a preoperative pure-tone average (PTA) of 41 dB to a postoperative PTA average of 29 dB (P < .0001). A functional minimally invasive approach to cholesteatoma surgery provided equivalent residual rates but higher recurrence rates compared to published canal wall down mastoidectomy. Endoscopic techniques were helpful in providing adequate views while minimizing exposure. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.
Development of Bariatric and Metabolic Endoscopy
Li, Shi-Han; Wang, Yong-Jun; Zhang, Shu-Tian
2018-01-01
Objective: With the evolution of society and changes in human lifestyle, obesity is becoming increasingly prevalent worldwide, and obesity-related comorbidities such as diabetes, hyperlipidemia, hypertension, and coronary heart disease are more common. As a result, new devices and methods for bariatric and metabolic endoscopy are being developed for clinical use, offering new options for patients. This review discussed the progress in bariatric and metabolic endoscopy. Data Sources: This review was based on data in articles published in the PubMed database up to September 2017, with the following keywords: “obesity”, “endoscopy”, “weight loss”, and “metabolism”. Study Selection: Original articles about various endoscopic methods of weight loss and other reviews of bariatric and metabolic endoscopy were included and analyzed. Results: The technology of bariatric and metabolic endoscopy has advanced rapidly in recent years. The intragastric balloon (IGB), with its comparatively long period of development, is the most mature and widely used instrument. Multiple new endoscopic devices have been created in recent years, with different targets to achieve weight loss. Despite the proliferation of new devices, the lack of clinical data results in a shortage of clinical experience and instruction in the use of this new equipment. Conclusions: Bariatric and metabolic endoscopy would help obese people lose weight or prepare for bariatric surgery and hopefully alleviate some of the complications of bariatric procedures. Adequate studies and data are still needed for the new endoscopic devices. PMID:29271386
Efficiency of endoscopy units can be improved with use of discrete event simulation modeling.
Sauer, Bryan G; Singh, Kanwar P; Wagner, Barry L; Vanden Hoek, Matthew S; Twilley, Katherine; Cohn, Steven M; Shami, Vanessa M; Wang, Andrew Y
2016-11-01
Background and study aims: The projected increased demand for health services obligates healthcare organizations to operate efficiently. Discrete event simulation (DES) is a modeling method that allows for optimization of systems through virtual testing of different configurations before implementation. The objective of this study was to identify strategies to improve the daily efficiencies of an endoscopy center with the use of DES. Methods: We built a DES model of a five procedure room endoscopy unit at a tertiary-care university medical center. After validating the baseline model, we tested alternate configurations to run the endoscopy suite and evaluated outcomes associated with each change. The main outcome measures included adequate number of preparation and recovery rooms, blocked inflow, delay times, blocked outflows, and patient cycle time. Results: Based on a sensitivity analysis, the adequate number of preparation rooms is eight and recovery rooms is nine for a five procedure room unit (total 3.4 preparation and recovery rooms per procedure room). Simple changes to procedure scheduling and patient arrival times led to a modest improvement in efficiency. Increasing the preparation/recovery rooms based on the sensitivity analysis led to significant improvements in efficiency. Conclusions: By applying tools such as DES, we can model changes in an environment with complex interactions and find ways to improve the medical care we provide. DES is applicable to any endoscopy unit and would be particularly valuable to those who are trying to improve on the efficiency of care and patient experience.
Efficiency of endoscopy units can be improved with use of discrete event simulation modeling
Sauer, Bryan G.; Singh, Kanwar P.; Wagner, Barry L.; Vanden Hoek, Matthew S.; Twilley, Katherine; Cohn, Steven M.; Shami, Vanessa M.; Wang, Andrew Y.
2016-01-01
Background and study aims: The projected increased demand for health services obligates healthcare organizations to operate efficiently. Discrete event simulation (DES) is a modeling method that allows for optimization of systems through virtual testing of different configurations before implementation. The objective of this study was to identify strategies to improve the daily efficiencies of an endoscopy center with the use of DES. Methods: We built a DES model of a five procedure room endoscopy unit at a tertiary-care university medical center. After validating the baseline model, we tested alternate configurations to run the endoscopy suite and evaluated outcomes associated with each change. The main outcome measures included adequate number of preparation and recovery rooms, blocked inflow, delay times, blocked outflows, and patient cycle time. Results: Based on a sensitivity analysis, the adequate number of preparation rooms is eight and recovery rooms is nine for a five procedure room unit (total 3.4 preparation and recovery rooms per procedure room). Simple changes to procedure scheduling and patient arrival times led to a modest improvement in efficiency. Increasing the preparation/recovery rooms based on the sensitivity analysis led to significant improvements in efficiency. Conclusions: By applying tools such as DES, we can model changes in an environment with complex interactions and find ways to improve the medical care we provide. DES is applicable to any endoscopy unit and would be particularly valuable to those who are trying to improve on the efficiency of care and patient experience. PMID:27853739
Experimental investigation of a bioartificial capsule flowing in a narrow tube
NASA Astrophysics Data System (ADS)
Risso, Frédéric; Collé-Paillot, Fabienne; Zagzoule, Mokhtar
This work is an experimental study of the motion and deformation of a bioartificial capsule flowing in a tube of 4 mm diameter. The capsules, initially designed for medical applications, are droplets of salt water surrounded by a thin polymeric membrane. They are immersed in a very viscous Newtonian silicone oil that flows through a tube in the Stokes regime. The properties of the capsules were carefully determined. Two previous experimental papers were devoted to their characterization by osmotic swelling and compression between two plates. The present work also provides a series of tests that allows an accurate definition of the experimental model under investigation. The capsules are buoyant and initially quasi-spherical. Nevertheless, buoyancy and small departures from sphericity are shown to have no significant effects, provided the flowing velocity is large enough for the viscous stress to become predominant. The capsules are also initially slightly over-inflated, but there is no mass transfer through the membrane during the present experiments. Their volume therefore remains constant. The membrane can be described as an elastic two-dimensional material, the elastic moduli of which are independent of the deformation. Far from the tube ends, the capsule reaches a steady state that depends on two parameters: the capillary number, Ca; and the ratio of the radius of the capsule to that of the tube, a/R. The capillary number, which compares the hydrodynamic stresses to the elastic tensions in the membrane, was varied between 0 and 0.125. The radius ratio, which measures the magnitude of the confinement, was varied from 0.75 to 0.95. In the range investigated, the membrane material always remains in the elastic domain. At fixed a/R, the capsule is stretched in the axial direction when Ca is increased. The process of deformation involves two main stages. At small to moderate Ca, the lateral dimension of the capsule decreases whereas its axial length increases. The capsule is rounded at both ends, but the curvature of its rear decreases as Ca increases. At large Ca, the rear buckles inward. Then, the negative rear curvature goes on decreasing whereas the lateral dimension of the capsule reaches a constant value. On the other hand, increasing a/R promotes the deformation: the process remains qualitatively the same, but the different stages are attained for smaller values of Ca. Comparisons with available numerical simulations show that the results are strongly dependent on the properties of the capsules.
Polar tent for reduced perturbation of NIF ignition capsules
NASA Astrophysics Data System (ADS)
Hammel, B. A.; Pickworth, L.; Stadermann, M.; Field, J.; Robey, H.; Scott, H. A.; Smalyuk, V.
2016-10-01
In simulations, a tent that contacts the capsule near the poles and departs tangential to the capsule surface greatly reduces the capsule perturbation, and the resulting mass injected into the hot-spot, compared to current capsule support methods. Target fabrication appears feasible with a layered tent (43-nm polyimide + 8-nm C) for increased stiffness. We are planning quantitative measurements of the resulting shell- ρR perturbation near peak implosion velocity (PV) using enhanced self-emission backlighting, achieved by adding 1% Ar to the capsule fill in Symcaps (4He + H). Layered DT implosions are also planned for an integrated test of capsule performance. We will describe the design and simulation predictions. Prepared by LLNL under Contract DE-AC52-07NA27344.
Zhang, Ziying; Du, Jun; Wei, Zhengying; Wang, Zhen; Li, Minghui
2018-02-01
Cellular adhesion plays a critical role in biological systems and biomedical applications. Cell deformation and biophysical properties of adhesion molecules are of significance for the adhesion behavior. In the present work, dynamic adhesion of a deformable capsule to a planar substrate, in a linear shear flow, is numerically simulated to investigate the combined influence of membrane deformability (quantified by the capillary number) and bond formation/dissociation rates on the adhesion behavior. The computational model is based on the immersed boundary-lattice Boltzmann method for the capsule-fluid interaction and a probabilistic adhesion model for the capsule-substrate interaction. Three distinct adhesion states, detachment, rolling adhesion and firm adhesion, are identified and presented in a state diagram as a function of capillary number and bond dissociation rate. The impact of bond formation rate on the state diagram is further investigated. Results show that the critical bond dissociation rate for the transition of rolling or firm adhesion to detachment is strongly related to the capsule deformability. At the rolling-adhesion state, smaller off rates are needed for larger capillary number to increase the rolling velocity and detach the capsule. In contrast, the critical off rate for firm-to-detach transition slightly increases with the capillary number. With smaller on rate, the effect of capsule deformability on the critical off rates is more pronounced and capsules with moderate deformability are prone to detach by the shear flow. Further increasing of on rate leads to large expansion of both rolling-adhesion and firm-adhesion regions. Even capsules with relatively large deformability can maintain stable rolling adhesion at certain off rate.
Trypan blue staining of the anterior capsule under an air bubble with a modified cannula.
Toprak, Ahmet Baris; Erkin, Esin Fatma; Guler, Cenap
2003-01-01
To attain good visibility of the anterior capsule in the advanced or white cataract, trypan blue 0.1% is used to stain the anterior capsule. The dye is usually injected under an air bubble. However, it is difficult to inject the dye properly due to capillary forces. An ordinary anterior chamber cannula was modified and its coverage area increased to facilitate the staining of the anterior capsule under an air bubble. The anterior capsule was stained properly by using the modified cannula in all of the cases.
Unusual Internal Astigmatism Due to Severe Capsule Contraction Syndrome.
Zéboulon, Pierre; Gatinel, Damien
2018-01-01
To describe a case of severe capsule contraction syndrome causing significant astigmatism due to intraocular lens (IOL) folding. Case report. Capsule fibrosis and contraction resulted in bending of the hydrophilic IOL along its long axis. Anterior Nd:YAG capsulotomy resolved the situation and restored the patient's visual acuity. Hydrophilic IOLs are more susceptible to capsule contraction due to the increased flexibility of highly hydrated materials. They should be avoided in patients at risk of capsule contraction to prevent ocular complications. [J Refract Surg. 2018;34(1):65-67.]. Copyright 2018, SLACK Incorporated.
NASA Astrophysics Data System (ADS)
Wilson, D. C.; Spears, B. K.; Hatchett, S. P., Ii; Cerjan, C. J.; Springer, P. T.; Clark, D. S.; Edwards, M. J.; Salmonson, J. D.; Weber, S. V.; Hammel, B. A.; Grim, G. P.; Herrmann, H. W.; Wilke, M. D.
2010-08-01
Diagnostics such as neutron yield, ion temperature, image size and shape, and bang time in capsules with >~25 % deuterium fuel show changes due to burn product heating. The comparison of performance between a THD(2%) and THD(35%) can help predict ignition in a TD(50%) capsule. Surrogacy of THD capsules to TD(50%) is incomplete due to variations in fuel molecular vapour pressures. TD(25-35%) capsules might be preferred to study hot spot heating, but at the risk of increased fuel/ablator mixing.
Application of robotics in gastrointestinal endoscopy: A review
Yeung, Baldwin Po Man; Chiu, Philip Wai Yan
2016-01-01
Multiple robotic flexible endoscope platforms have been developed based on cross specialty collaboration between engineers and medical doctors. However, significant number of these platforms have been developed for the natural orifice transluminal endoscopic surgery paradigm. Increasing amount of evidence suggest the focus of development should be placed on advanced endolumenal procedures such as endoscopic submucosal dissection instead. A thorough literature analysis was performed to assess the current status of robotic flexible endoscopic platforms designed for advanced endolumenal procedures. Current efforts are mainly focused on robotic locomotion and robotic instrument control. In the future, advances in actuation and servoing technology, optical analysis, augmented reality and wireless power transmission technology will no doubt further advance the field of robotic endoscopy. Globally, health systems have become increasingly budget conscious; widespread acceptance of robotic endoscopy will depend on careful design to ensure its delivery of a cost effective service. PMID:26855540
Goh, Khean-Lee
2011-05-01
Gastrointestinal endoscopy started in the early 1970s in Malaysia with the help of Japanese doctors. It has evolved over the past 30 years. The gastrointestinal endoscopy unit at the University of Malaya Medical Centre has been in the forefront in providing endoscopy services to patients as well as training doctors in endoscopy in the country. In recent years, trainees have included those from neighboring countries in South-East Asia. Among our most significant achievements is the organization of regular international therapeutic endoscopy workshops since 1993 where leading endoscopists from throughout the world have accepted our invitation as teaching faculty. In 2008, the World Organization of Digestive Endoscopy accorded the high distinction of Centre of Excellence to the endoscopy unit of the University of Malaya Medical Centre. © 2011 The Author. Digestive Endoscopy © 2011 Japan Gastroenterological Endoscopy Society.
1991-01-01
(1) The number of endoscopic examinations performed is rising. Epidemiological data and the workload of well developed units show that annual requirements per head of population are approaching: Upper gastrointestinal 1 in 100 Flexible sigmoidoscopy 1 in 500 Colonoscopy 1 in 500 ERCP 1 in 2000 (2) Open access endoscopy to general practitioners is desirable and increasingly sought. For a district general hospital serving a population of 250,000, this workload entails about 3500 procedures annually, performed during 10 half day routine sessions plus emergency work. (3) High standards of training and experience are needed by all staff, who must work in purpose built accommodation designed to promote efficient and safe practice. (4) The endoscopy unit should be adjacent to day care facilities and near the x ray department. There should be easy access to wards. (5) An endoscopy unit needs at least two endoscopy rooms; a fully ventilated cleaning/disinfection area; rooms for patient reception, preparation, and recovery; and accommodation for administration, storage, and staff amenities. (6) The service should be consultant based. At least 10 clinical sessions are required, made up of six or more consultant sessions and two to four clinical assistant, hospital practitioner, or staff specialist sessions. Each consultant should be expected to commit at least two sessions weekly to endoscopy. Extra consultant sessions may be needed to provide an efficient service. (7) A specially trained nursing sister (grade G or H) and five other endoscopy nurses are needed to care for the patients; their work may be supplemented by care assistants. (8) A new post of endoscopy department assistant (analogous to an operating department assistant) is proposed to maintain and prepare instruments, and to give technical assistance during procedures. (9) A full time secretary should be employed. Records, appointments, and audit should be computer based. (10) ERCP needs the collaboration of an interventional radiologist working with high quality x ray equipment in a specially prepared radiology screening room. This facility may need to serve more than one hospital. (11) A gastrointestinal measurement laboratory can conveniently be combined with the endoscopy unit. In some hospitals one or more gastrointestinal measurement technicians may staff this laboratory. (12) An endoscopy unit is a service department analogous to a radiology department. It needs an annual budget.
Indicators of safety compromise in gastrointestinal endoscopy.
Borgaonkar, Mark Ram; Hookey, Lawrence; Hollingworth, Roger; Kuipers, Ernst J; Forster, Alan; Armstrong, David; Barkun, Alan; Bridges, Ron; Carter, Rose; de Gara, Chris; Dube, Catherine; Enns, Robert; Macintosh, Donald; Forget, Sylviane; Leontiadis, Grigorios; Meddings, Jonathan; Cotton, Peter; Valori, Roland
2012-02-01
The importance of quality indicators has become increasingly recognized in gastrointestinal endoscopy. Patient safety requires the identification and monitoring of occurrences associated with harm or the potential for harm. The identification of relevant indicators of safety compromise is, therefore, a critical element that is key to the effective implementation of endoscopy quality improvement programs. To identify key indicators of safety compromise in gastrointestinal endoscopy. The Canadian Association of Gastroenterology Safety and Quality Indicators in Endoscopy Consensus Group was formed to address issues of quality in endoscopy. A subcommittee was formed to identify key safety indicators. A systematic literature review was undertaken, and articles pertinent to safety in endoscopy were identified and reviewed. All complications and measures used to document safety were recorded. From this, a preliminary list of 16 indicators was compiled and presented to the 35-person consensus group during a three-day meeting. A revised list of 20 items was subsequently put to the consensus group for vote for inclusion on the final list of safety indicators. Items were retained only if the consensus group highly agreed on their importance. A total of 19 indicators of safety compromise were retained and grouped into the three following categories: medication-related - the need for CPR, use of reversal agents, hypoxia, hypotension, hypertension, sedation doses in patients older than 70 years of age, allergic reactions and laryngospasm⁄bronchospasm; procedure-related early - perforation, immediate postpolypectomy bleeding, need for hospital admission or transfer to emergency department from the gastroenterology unit, instrument impaction, severe persistent abdominal pain requiring evaluation proven to not be perforation; and procedure-related delayed - death within 30 days of procedure, 14-day unplanned hospitalization, 14-day unplanned contact with a health provider, gastrointestinal bleeding within 14 days of procedure, infection or symptomatic metabolic complications. The 19 indicators of safety compromise in endoscopy, identified by a rigorous, evidence-based consensus process, provide clear outcomes to be recorded by all facilities as part of their continuing quality improvement programs.
Application of Bio-digestion for Capsule Gelatin-- From the Pharmaceutical Wastes to the Manure
NASA Astrophysics Data System (ADS)
Pan, C.; Huang, S.; Chang, Y.; Wen, J.
2013-12-01
The purpose of this study was to bio-digest the capsule gelatin from the waste of pharmaceutical processes such as cutting and stamping for capsule shells producing. We screened soil bacterial flora for capsule gelatin biolysis, and found the most competent one named Yuntech-7. A 15% (w/w) of capsule gelatin could fully digested by Yuntech-7 for 3 days growth with an N-limited medium in a 37°C incubator. In order to recycle and reuse the gelatin waste, the different percentages of capsule gelatin were co-composted with the vegetable residues to produce manure in an anaerobic fermentation by an extra Yuntech-7 inoculation. After 14 days incubation, we collected the filtrate to examine the contents of N, P, and K. The data shows that the P and K keep the same value by roughly between the blank and the control sets, but the total N values were approximately a 5-fold increase in 20% and a 10-fold increase in 40% of capsule gelatin integrated. We suggested that the capsule gelatin was majorly decomposed by Yuntech-7, because the total N value was no observable change in the capsule gelatin and vegetable residues co-compost with a Yuntech-7-free condition. We also performed some field tests using the capsule gelatin generated liquid manure, and the preliminary test shows the plants got great benefits on culture size and in environmental resistance. In conclusion, the process in bio-digestion of waste capsule gelatin by soil bacteria, Yuntech-7, was produced a valuable manure not only aliment the plants but also complement the soil bacterial populations.
Development of Naphthalene PLIF for Visualizing Ablation Products From a Space Capsule Heat Shield
NASA Technical Reports Server (NTRS)
Combs, C. S.; Clemens, N. T.; Danehy, P. M.
2014-01-01
The Orion Multi-Purpose Crew Vehicle (MPCV) will use an ablative heat shield. To better design this heat shield and others that will undergo planetary entry, an improved understanding of the ablation process would be beneficial. Here, a technique developed at The University of Texas at Austin that uses planar laser-induced fluorescence (PLIF) of a low-temperature sublimating ablator (naphthalene) to enable visualization of the ablation products in a hypersonic flow is applied. Although high-temperature ablation is difficult and expensive to recreate in a laboratory environment, low-temperature sublimation creates a limited physics problem that can be used to explore ablation-product transport in a hypersonic flow-field. In the current work, a subscale capsule reentry vehicle model with a solid naphthalene heat shield has been tested in a Mach 5 wind tunnel. The PLIF technique provides images of the spatial distribution of sublimated naphthalene in the heat-shield boundary layer, separated shear layer, and backshell recirculation region. Visualizations of the capsule shear layer using both naphthalene PLIF and Schlieren imaging compared favorably. PLIF images have shown high concentrations of naphthalene in the capsule separated flow region, intermittent turbulent structures on the heat shield surface, and interesting details of the capsule shear layer structure. It was shown that, in general, the capsule shear layer appears to be more unsteady at lower angels of attack. The PLIF images demonstrated that during a wind tunnel run, as the model heated up, the rate of naphthalene ablation increased, since the PLIF signal increased steadily over the course of a run. Additionally, the shear layer became increasingly unsteady over the course of a wind tunnel run, likely because of increased surface roughness but also possibly because of the increased blowing. Regions with a relatively low concentration of naphthalene were also identified in the capsule backshell recirculation region and are most likely the result of cross-flow-induced vortices on the capsule afterbody.
Ryan, William R; Ramachandra, Tara; Hwang, Peter H
2011-03-01
To determine correlations between symptoms, nasal endoscopy findings, and computed tomography (CT) scan findings in post-surgical chronic rhinosinusitis (CRS) patients. Cross-sectional. A total of 51 CRS patients who had undergone endoscopic sinus surgery (ESS) completed symptom questionnaires, underwent endoscopy, and received an in-office sinus CT scan during one clinic visit. For metrics, we used the Sinonasal Outcomes Test-20 (SNOT-20) questionnaire, visual analog symptom scale (VAS), Lund-Kennedy endoscopy scoring scale, and Lund-MacKay (LM) CT scoring scale. We determined Pearson correlation coefficients, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) between scores for symptoms, endoscopy, and CT. The SNOT-20 score and most VAS symptoms had poor correlation coefficients with both endoscopy and CT scores (0.03-0.24). Nasal drainage of pus, nasal congestion, and impaired sense of smell had moderate correlation coefficients with endoscopy and CT (0.24-0.42). Endoscopy had a strong correlation coefficient with CT (0.76). Drainage, edema, and polyps had strong correlation coefficients with CT (0.80, 0.69, and 0.49, respectively). Endoscopy had a PPV of 92.5% and NPV of 45.5% for detecting an abnormal sinus CT (LM score ≥1). In post-ESS CRS patients, most symptoms do not correlate well with either endoscopy or CT findings. Endoscopy and CT scores correlate well. Abnormal endoscopy findings have the ability to confidently rule in the presence of CT opacification, thus validating the importance of endoscopy in clinical decision making. However, a normal endoscopy cannot assure a normal CT. Thus, symptoms, endoscopy, and CT are complementary in the evaluation of the post-ESS CRS patient. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc., Rhinological, and Otological Society, Inc.
Cai, Jing; Yu, Haibo
2017-01-01
Heterotopic gastric mucosa has been described at various locations of the body; however, the polyp composed of heterotopic gastric mucosa in the small intestine is rare. A 15-year-old boy visited us for investigation of recurrent episodes of melena. Capsule endoscopy (CE) revealed a polypoid tumor in the ileum, with an active nearby hemorrhage. Contrast-enhanced computed tomography (CECT) showed a tumor in the right quadrant of the abdomen, with a diameter of about 18 × 14 mm. The patient was diagnosed with polypoid gastric heterotopia. We performed an operation to resect the lesion. The patient recovered smoothly after surgery and was discharged on postoperative day 7 and followed up for 3 months. He has not experienced gastrointestinal intestinal (GI) symptoms up to now. Giant polypoid gastric heterotopia in the small intestine is extremely rare, which can express as an occasional finding with or without symptoms. Surgical resection is the preferred therapy when symptoms appear.
Primary intestinal lymphangiectasia: Minireview
Ingle, Sachin B; Hinge (Ingle), Chitra R
2014-01-01
Primary idiopathic intestinal lymphangiectasia is an unusual disease featured by the presence of dilated lymphatic channels which are located in the mucosa, submucosa or subserosa leading to protein loosing enteropathy.Most often affected were children and generally diagnosed before third year of life but may be rarely seen in adults too. Bilateral pitting oedema of lower limb is the main clinical manifestation mimicking the systemic disease and posing a real diagnostic dilemma to the clinicians to differentiate it from other common systemic diseases like Congestive cardiac failure, Nephrotic Syndrome, Protein Energy Malnutrition, etc. Diagnosis can be made on capsule endoscopy which can localise the lesion but unable to take biopsy samples. Thus, recently double-balloon enteroscopy and biopsy in combination can be used as an effective diagnostic tool to hit the correct diagnosis. Patients respond dramatically to diet constituting low long chain triglycerides and high protein content with supplements of medium chain triglyceride. So early diagnosis is important to prevent untoward complications related to disease or treatment for the sake of accurate pathological diagnosis. PMID:25325063
Ileal polypoid lymphangiectasia bleeding diagnosed and treated by double balloon enteroscopy
Park, Min Seon; Lee, Beom Jae; Gu, Dae Hoe; Pyo, Jeung-Hui; Kim, Kyeong Jin; Lee, Yun Ho; Joo, Moon Kyung; Park, Jong-Jae; Kim, Jae Seon; Bak, Young-Tae
2013-01-01
Intestinal lymphangiectasia is a rare disease characterized by focal or diffuse dilated enteric lymphatics with impaired lymph drainage. It causes protein-losing enteropathy and may lead to gastrointestinal bleeding. Commonly, lymphangiectasia presents as whitish spots or specks. To our knowledge, small bowel bleeding resulting from polypoid intestinal lymphangiectasia has not been reported. Here, we report a rare case of active bleeding from the small bowel caused by polypoid lymphangiectasia with a review of the relevant literature. An 80-year-old woman was hospitalized for melena. Esophagogastroduodenoscopy could not identify the source of bleeding. Subsequent colonoscopy showed fresh bloody material gushing from the small bowel. An abdominal-pelvic contrast-enhanced computed tomography scan did not reveal any abnormal findings. Video capsule endoscopy showed evidence of active and recent bleeding in the ileum. To localize the bleeding site, we performed double balloon enteroscopy by the anal approach. A small, bleeding, polypoid lesion was found in the distal ileum and was successfully removed using endoscopic snare electrocautery. PMID:24363538
Marco-Lattur, Maria D; Payeras, Antoni; Campins, Antoni A; Pons, Jaume; Cifuentes, Carmen; Riera, Melcior
2011-02-01
Although paradoxical virological and immunological response after HAART has been well studied, intestinal lymphangiectasia (IL) in HIV-1 infected patients has not previously described. To describe HIV patients who developed IL. Clinical Case series. 4 patients with HIV and IL diagnosis based on clinical, endoscopic and pathological findings. All four cases had prior mycobacterial infections with abdominal lymph node involvement and a very low CD4 cell count nadir. They developed intestinal lymphangiectasia despite appropriate virological suppression with HAART and repeatedly negative mycobacterial cultures. Two patients were clinically symptomatic with oedemas, ascites, diarrhoea, asthenia, weight loss; but the other two were diagnosed with malabsorption as a result of laboratory findings, with hypoproteinemia and hypoalbuminemia. Three of them were diagnosed by video capsule endoscopy. IL should be considered in HIV-1 infected patients who present with clinical or biochemical malabsorption parameters when there is no immunological recovery while on HAART. Copyright © 2010 Elsevier España, S.L. All rights reserved.
Hsu, Wei-Fan; Tsang, Yuk-Ming; Teng, Chung-Jen; Chung, Chen-Shuan
2015-01-21
Obscure gastrointestinal bleeding is an uncommonly encountered and difficult-to-treat clinical problem in gastroenterology, but advancements in endoscopic and radiologic imaging modalities allow for greater accuracy in diagnosing obscure gastrointestinal bleeding. Ectopic varices account for less than 5% of all variceal bleeding cases, and jejunal variceal bleeding due to extrahepatic portal hypertension is rare. We present a 47-year-old man suffering from obscure gastrointestinal bleeding. Computed tomography of the abdomen revealed multiple vascular tufts around the proximal jejunum but no evidence of cirrhosis, and a visible hypodense filling defect suggestive of thrombus was visible in the superior mesenteric vein. Enteroscopy revealed several serpiginous varices in the proximal jejunum. Serologic data disclosed protein C deficiency (33.6%). The patient was successfully treated by therapeutic balloon-assisted enteroscopy and long-term anticoagulant therapy, which is normally contraindicated in patients with gastrointestinal bleeding. Diagnostic modalities for obscure gastrointestinal bleeding, such as capsule endoscopy, computed tomography enterography, magnetic resonance enterography, and enteroscopy, were also reviewed in this article.
Macdonald, Jonathan; Porter, Victoria; Scott, Neil W; McNamara, Deirdre
2010-10-01
Small bowel angiodysplasia accounts for 30 to 40% of cases of obscure gastrointestinal bleeding and is associated with significant morbidity and mortality. Identifying lesions can be difficult. Small bowel capsule endoscopy (SBCE) is a significant advance on earlier diagnostic techniques. The cause of angiodysplasia is unknown and the natural history poorly understood. Many lesions are thought to arise from a degenerative process associated with ageing, local vascular anomalies, and tissue hypoxia. Nonpathologic lymphangiectasias are commonly seen throughout the small bowel and are considered a normal finding. To determine whether there is an association between lymphangiectasias, angiodysplasia, and atherosclerosis related conditions. Relevant information was collected from a dedicated SBCE database. Logistic regression analysis was used to examine associations between angiodysplasia, lymphangiectasia, patient demographics, and comorbidity. In all, 180 patients underwent SBCE during the study period, 46 (25%) had angiodysplasia and 47 (26%) lymphangiectasia. Lymphangiectasia were seen in 24 (52%) of 46 with angiodysplasia, in 16 (19%) of 84 with obscure gastrointestinal bleeding without angiodysplasia and in 7 (14%) of 50 without gastrointestinal bleeding. Logistic regression analysis confirmed a strong positive association between angiodysplasia and lymphangiectasia; odds ratio 4.42, P<0.003. Angiodysplasias were also associated with increasing age; odds ratio 1.1. There was no correlation with any other patient characteristic. Lymphangiectasia are strongly associated with the presence of small intestinal angiodysplasia and may represent a useful clinical marker for this condition. Angiodysplasia are also associated with increasing age. Conditions associated with systemic atherosclerosis did not increase the risk of angiodysplasia.
Sun, Jian-Hui; Huo, Hai-Ru; Li, Xiao-Qin; Li, Hong-Mei; Qin, De-Huai; Wu, Chun
2018-04-01
Huanshao capsule is widely used in irregular menstruation and has achieved a good effect. Huanshao capsule can promote gonad development in mice, significantly improve the ovarian index in mice, increase estrogen level and reduce FSH level in rats, inhibit the pain response induced by oxytocin and estrogen, inhibit writhing reaction induced by acetic acid pain in mice. Due to the complexity of traditional Chinese medical formula, the pharmacological mechanism of the treatment on the irregular menstruation of the Huanshao capsule is unclear. In this study, the internet-based computation platform (www.tcmip.cn)was used to explore the molecular mechanism of Huanshao capsule on the menstrual. The aim of this study was to find the molecular mechanism of Huanshao capsule in treating menstrual. In the study of the molecular mechanism of Huanshao capsule in the treatment of menstrual by using the internet-based computation platform, Huanshao capsule maybe treat the menstrual by the pathway of endocrine system, GnRH signal transduction pathway, estrogen signal transduction pathway, oxytocin signaling pathway, thyroid hormone signaling pathway, VEGF signaling pathway, FCεRI signaling pathway and purine metabolism and nucleotide metabolism. The early pharmacological study confirmed Huanshao capsule could increase the serum estradiol level and decrease follicle stimulating hormone level and the traditional Chinese medicine pharmacology coincide with the prediction result of internet-based computation platform which roles as the pathway of GnRH signaling pathway and estrogen signal transduction pathway. Other pathway needs further experimental verification. Copyright© by the Chinese Pharmaceutical Association.
Genome-Wide Discovery of Genes Required for Capsule Production by Uropathogenic Escherichia coli.
Goh, Kelvin G K; Phan, Minh-Duy; Forde, Brian M; Chong, Teik Min; Yin, Wai-Fong; Chan, Kok-Gan; Ulett, Glen C; Sweet, Matthew J; Beatson, Scott A; Schembri, Mark A
2017-10-24
Uropathogenic Escherichia coli (UPEC) is a major cause of urinary tract and bloodstream infections and possesses an array of virulence factors for colonization, survival, and persistence. One such factor is the polysaccharide K capsule. Among the different K capsule types, the K1 serotype is strongly associated with UPEC infection. In this study, we completely sequenced the K1 UPEC urosepsis strain PA45B and employed a novel combination of a lytic K1 capsule-specific phage, saturated Tn 5 transposon mutagenesis, and high-throughput transposon-directed insertion site sequencing (TraDIS) to identify the complement of genes required for capsule production. Our analysis identified known genes involved in capsule biosynthesis, as well as two additional regulatory genes ( mprA and lrhA ) that we characterized at the molecular level. Mutation of mprA resulted in protection against K1 phage-mediated killing, a phenotype restored by complementation. We also identified a significantly increased unidirectional Tn 5 insertion frequency upstream of the lrhA gene and showed that strong expression of LrhA induced by a constitutive Pcl promoter led to loss of capsule production. Further analysis revealed loss of MprA or overexpression of LrhA affected the transcription of capsule biosynthesis genes in PA45B and increased sensitivity to killing in whole blood. Similar phenotypes were also observed in UPEC strains UTI89 (K1) and CFT073 (K2), demonstrating that the effects were neither strain nor capsule type specific. Overall, this study defined the genome of a UPEC urosepsis isolate and identified and characterized two new regulatory factors that affect UPEC capsule production. IMPORTANCE Urinary tract infections (UTIs) are among the most common bacterial infections in humans and are primarily caused by uropathogenic Escherichia coli (UPEC). Many UPEC strains express a polysaccharide K capsule that provides protection against host innate immune factors and contributes to survival and persistence during infection. The K1 serotype is one example of a polysaccharide capsule type and is strongly associated with UPEC strains that cause UTIs, bloodstream infections, and meningitis. The number of UTIs caused by antibiotic-resistant UPEC is steadily increasing, highlighting the need to better understand factors (e.g., the capsule) that contribute to UPEC pathogenesis. This study describes the original and novel application of lytic capsule-specific phage killing, saturated Tn 5 transposon mutagenesis, and high-throughput transposon-directed insertion site sequencing to define the entire complement of genes required for capsule production in UPEC. Our comprehensive approach uncovered new genes involved in the regulation of this key virulence determinant. Copyright © 2017 Goh et al.
2017-01-01
Non-steroidal anti-inflammatory drugs (NSAIDs) are a broad class of non glucocorticoid drugs which are extensively used in anti-inflammatory, analgesic, and antipyretic therapies. However, NSAIDs may cause many side effects, most commonly in gastrointestinal(GI) tract. Cardiovascular system, kidney, liver, central nervous system and hematopoietic system are also involved. NSAID-induced GI side effects not only endanger the patients' health, increase mortality, but also greatly increase the cost of medical care. Therefore, how to reduce GI side effects is of particular concern to clinicians. The Chinese Rheumatism Data Center(CRDC) and Chinese Systemic Lupus Erythematosus Treatment and Research Group(CSTAR) compose a "Recommendation for the prevention and treatment of non-steroidal anti-inflammatory drug-induced gastrointestinal ulcers and its complications" , as following: (1) GI lesions are the most common side effects of NSAIDs. (2) NSAID-induced GI side effects include gastritis, esophagitis, gastric and duodenal ulcers, bleeding, perforation and obstruction. (3) With the application of capsule endoscopy and small intestinal endoscopy, growing attention is being paid to the NASID-induced small intestine mucosa damage, which is mainly erosion and ulcer. (4) Risk factors related to NSAID-induced GI ulcers include: Helicobacter pylori (Hp) infection, age> 65 years, past history of GI ulcers, high doses of NSAIDs, multiple-drug combination therapy, and comorbidities, such as cardiovascular disease and nephropathy.(5) GI and cardiovascular function should be evaluated before using NSAIDs and gastric mucosal protective agents. (6) The risk of GI ulcers and complications caused by selective cyclooxygenase-2 (COX-2) inhibitors is less than that of non-selective COX-2 inhibitors. (7)Hp eradication therapy helps to cure GI ulcers and prevent recurrence when Hp infection is positive in NSAID-induced ulcers. (8) Proton pump inhibitor (PPI) is the first choice for the prevention and treatment of NSAID-induced GI injury. Gastric mucosal protective agents also suggested.(9) H 2 receptor antagonist (H 2 RA) can reduce the risk of NSAID-induced duodenal injury, however, the therapeutic effect of NSAID-induced gastric ulcer remains to be further confirmed. (10) Endoscopic treatment is the first recommendation for NSAID-induced peptic ulcers combined with upper GI bleeding, high-dose PPI effectively prevent rebleeding, reduce the possibility of surgery and mortality rate.
Gastrointestinal endoscopy: infection and disinfection.
O'Connor, H J; Axon, A T
1983-11-01
The past decade has seen the development of an array of complex flexible fibreoptic instruments for gastrointestinal (GI) endoscopy, and an increasing use of these for diagnostic and therapeutic purposes. It has been recognised more recently that the use of contaminated endoscopic equipment can lead to serious and occasionally fatal infections. Infection with a wide variety of micro-organisms has been reported following oesophago-gastroduodenoscopy (OGD) and endoscopic retrograde cholangio-pancreatography (ERCP).
Gastrointestinal endoscopy: infection and disinfection.
O'Connor, H J; Axon, A T
1983-01-01
The past decade has seen the development of an array of complex flexible fibreoptic instruments for gastrointestinal (GI) endoscopy, and an increasing use of these for diagnostic and therapeutic purposes. It has been recognised more recently that the use of contaminated endoscopic equipment can lead to serious and occasionally fatal infections. Infection with a wide variety of micro-organisms has been reported following oesophago-gastroduodenoscopy (OGD) and endoscopic retrograde cholangio-pancreatography (ERCP). PMID:6414894
Protective Role of the Capsule and Impact of Serotype 4 Switching on Streptococcus mitis
Rukke, Håkon V.; Kalluru, Raja Sab; Repnik, Urska; Gerlini, Alice; José, Ricardo J.; Periselneris, Jimstan; Marshall, Helina; Griffiths, Gareth; Oggioni, Marco Rinaldo; Brown, Jeremy S.
2014-01-01
The polysaccharide capsule surrounding Streptococcus pneumoniae is essential for virulence. Recently, Streptococcus mitis, a human commensal and a close relative of S. pneumoniae, was also shown to have a capsule. In this study, the S. mitis type strain switched capsule by acquisition of the serotype 4 capsule locus of S. pneumoniae TIGR4, following induction of competence for natural transformation. Comparison of the wild type with the capsule-switching mutant and with a capsule deletion mutant showed that the capsule protected S. mitis against phagocytosis by RAW 264.7 macrophages. This effect was enhanced in the S. mitis strain expressing the S. pneumoniae capsule, which showed, in addition, increased resistance against early clearance in a mouse model of lung infection. Expression of both capsules also favored survival in human blood, and the effect was again more pronounced for the capsule-switching mutant. S. mitis survival in horse blood or in a mouse model of bacteremia was not significantly different between the wild type and the mutant strains. In all models, S. pneumoniae TIGR4 showed higher rates of survival than the S. mitis type strain or the capsule-switching mutant, except in the lung model, in which significant differences between S. pneumoniae TIGR4 and the capsule-switching mutant were not observed. Thus, we identified conditions that showed a protective function for the capsule in S. mitis. Under such conditions, S. mitis resistance to clearance could be enhanced by capsule switching to serotype 4, but it was enhanced to levels lower than those for the virulent strain S. pneumoniae TIGR4. PMID:24958712
NASA Astrophysics Data System (ADS)
Singh, Rajesh; Sarkar, Kausik
2012-11-01
Deformability of red blood cells affects hydrodynamic properties of blood and thereby physiological functions in many cardiovascular diseases, e.g. in sickle cell anemia and malaria, the cell membrane becomes stiff affecting their circulation through microvessels. Here, we numerically simulate the hydrodynamic interaction between a pair of cell-like capsules in a free shear flow, using a front-tracking method. The membrane is modeled using various constitutive equations. By varying the stiffness of one capsule (C2) and keeping all other parameters constant, we find a significant effect on the deformation and trajectory of the other (C1) . Increasing the stiffness of C2 surprisingly increases the peak deformation of C1 while decreasing the cross-stream shift in its trajectory However, the relative trajectory between capsules remains the same. Effects of constitutive laws and difference in behaviors between capsules and drops are investigated explaining underlying physics. partial support from NSF.
Update on narrow band imaging in disorders of the upper gastrointestinal tract.
Singh, Rajvinder; Lee, Shok Y; Vijay, Nimal; Sharma, Prateek; Uedo, Noriya
2014-03-01
With the ever-increasing concern regarding morbidity and mortality associated with diseases of the gastrointestinal tract, the importance of an effective and efficient diagnostic tool cannot be overstated. The standard of care currently is an examination using conventional white light endoscopy. This approach may occasionally overlook areas exhibiting a premalignant change. Numerous image-enhanced modalities have been recently introduced. Narrow band imaging (NBI) appears to be the most prominent of these and perhaps the most commonly used. Thepresent review will focus on some of the newer studies on NBI and its utility in the diagnosis of malignant, pre-malignant and chronic inflammatory conditions of the upper gastrointestinal tract. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.
Abdul-Baki, Heitham; Schoen, Robert E; Dean, Katie; Rose, Sherri; Leffler, Daniel A; Kuganeswaran, Eliathamby; Morris, Michele; Carrell, David; Mehrotra, Ateev
2015-10-01
Colonoscopy is the predominant method for colorectal cancer screening in the United States. Previous studies have documented variation across physicians in colonoscopy quality as measured by the adenoma detection rate (ADR). ADR is the primary quality measure of colonoscopy examinations and an indicator of the likelihood of subsequent colorectal cancer. There is interest in mechanisms to improve the ADR. In Central Illinois, a local employer and a quality improvement organization partnered to publically report physician colonoscopy quality. We assessed whether this initiative was associated with an improvement in the ADR. We compared ADRs before and after public reporting at a private practice endoscopy center with 11 gastroenterologists in Peoria, Illinois, who participated in the initiative. To generate the ADR, colonoscopy and pathology reports from examinations performed over 4 years at the endoscopy center were analyzed by using previously validated natural language processing software. A central Illinois endoscopy center. The ADR in the pre-public reporting period was 34.3% and 39.2% in the post-public reporting period (an increase of 4.9%, P < .001). The increase in the right-sided ADR was 5.1% (P < .01), whereas the increase in the left-sided ADR was 2.1% (P < .05). The increase in the ADR was 7.8% for screening colonoscopies (P < 0.05) and 3.5% for nonscreening colonoscopies (P < .05). All but 1 physician's ADR increased (range -2.7% to 10.5%). There was no statistically significant change in the advanced ADR (increase of 0.8%, P = .22). There was no concurrent control group to assess whether the increased ADR was due to a secular trend. A public reporting initiative on colonoscopy quality was associated with an increase in ADR. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Improvement in Capsule Abort Performance Using Supersonic Aerodynamic Interaction by Fences
NASA Astrophysics Data System (ADS)
Koyama, Hiroto; Wang, Yunpeng; Ozawa, Hiroshi; Doi, Katsunori; Nakamura, Yoshiaki
The space transportation system will need advanced abort systems to secure crew against serious accidents. Here this study deals with the capsule-type space transportation systems with a Launch Abort System (LAS). This system is composed of a conic capsule as a Launch Abort Vehicle (LAV) and a cylindrical rocket as a Service Module (SM), and the capsule is moved away from the rocket by supersonic aerodynamic interactions in an emergency. We propose a method to improve the performance of the LAV by installing fences at the edges of surfaces on the rocket and capsule sides. Their effects were investigated by experimental measurements and numerical simulations. Experimental results show that the fences on the rocket and capsule surfaces increase the aerodynamic thrust force on the capsule by 70% in a certain clearance between the capsule and rocket. Computational results show the detailed flow fields where the centripetal flow near the surface on the rocket side is induced by the fence on the rocket side and the centrifugal flow near the surface on the capsule side is blocked by the fence on the capsule side. These results can confirm favorable effects of the fences on the performance of the LAS.
Wu, Xi-li; Sun, Wan-sen; Zhang, Wang-gang; Qiao, Cheng-lin; Wang, Zhu; Wang, Juan
2007-11-01
To explore the effect of Yishen capsule on the serum vascular endothelial growth factor (VEGF), the cell immunity and the theraphic. Serum VEGF and T cell subsets were studied in 30 normal subjects and 83 patients before and after treatment. Compare with normal subjects, CD3, CD4, CD4/CD8 were decreased, CD8 and serum VEGF were increased obviously (P <0. 05 or P <0. 01). After three months treatment with YiShen capsule, CD4/CD8 was increased, CD8 and serum VEGF were decreased significantly (P <0.05 or P <0.01). Yishen capsule can reduce the proteinuria, increase the function of immunity and improve the clinical symptom of patients with chronic glomerulonephritis, achieved the effects of allevating chronic glomerular sclerosis ultimately.
Curatolo, William; Liu, Ping; Johnson, Barbara A; Hausberger, Angela; Quan, Ernest; Vendola, Thomas; Vatsaraj, Neha; Foulds, George; Vincent, John; Chandra, Richa
2011-07-01
Commercial azithromycin gelatin capsules (Zithromax®) are known to be bioequivalent to commercial azithromycin tablets (Zithromax®) when dosed in the fasted state. These capsules exhibit a reduced bioavailability when dosed in the fed state, while tablets do not. This gelatin capsule negative food effect was previously proposed to be due to slow and/or delayed capsule disintegration in the fed stomach, resulting in extended exposure of the drug to gastric acid, leading to degradation to des-cladinose-azithromycin (DCA). Azithromycin gelatin capsules were formulated with "superdisintegrants" to provide fast-dissolving capsules, and HPMC capsule shells were substituted for gelatin capsule shells, in an effort to eliminate the food effect. Healthy volunteers were dosed with these dosage forms under fasted and fed conditions; pharmacokinetics were evaluated. DCA pharmacokinetics were also evaluated for the HPMC capsule subjects. In vitro disintegration of azithromycin HPMC capsules in media containing food was evaluated and compared with commercial tablets and commercial gelatin capsules. When the two fast-dissolving capsule formulations were dosed to fed subjects, the azithromycin AUC was 38.9% and 52.1% lower than after fasted-state dosing. When HPMC capsules were dosed to fed subjects, the azithromycin AUC was 65.5% lower than after fasted-state dosing. For HPMC capsules, the absolute fasting-state to fed-state decrease in azithromycin AUC (on a molar basis) was similar to the increase in DCA AUC. In vitro capsule disintegration studies revealed extended disintegration times for commercial azithromycin gelatin capsules and HPMC capsules in media containing the liquid foods milk and Ensure®. Interaction of azithromycin gelatin and HPMC capsules with food results in slowed disintegration in vitro and decreased bioavailability in vivo. Concurrent measurement of serum azithromycin and the acid-degradation product DCA demonstrates that the loss of azithromycin bioavailability in the fed state is largely (and probably entirely) due to gastric degradation to DCA. Capsules can provide a useful and elegant dosage form for almost all drugs, but may result in a negative food effect for drugs as acid-labile as azithromycin.
Informative frame detection from wireless capsule video endoscopic images
NASA Astrophysics Data System (ADS)
Bashar, Md. Khayrul; Mori, Kensaku; Suenaga, Yasuhito; Kitasaka, Takayuki; Mekada, Yoshito
2008-03-01
Wireless capsule endoscopy (WCE) is a new clinical technology permitting the visualization of the small bowel, the most difficult segment of the digestive tract. The major drawback of this technology is the high amount of time for video diagnosis. In this study, we propose a method for informative frame detection by isolating useless frames that are substantially covered by turbid fluids or their contamination with other materials, e.g., faecal, semi-processed or unabsorbed foods etc. Such materials and fluids present a wide range of colors, from brown to yellow, and/or bubble-like texture patterns. The detection scheme, therefore, consists of two stages: highly contaminated non-bubbled (HCN) frame detection and significantly bubbled (SB) frame detection. Local color moments in the Ohta color space are used to characterize HCN frames, which are isolated by the Support Vector Machine (SVM) classifier in Stage-1. The rest of the frames go to the Stage-2, where Laguerre gauss Circular Harmonic Functions (LG-CHFs) extract the characteristics of the bubble-structures in a multi-resolution framework. An automatic segmentation method is designed to extract the bubbled regions based on local absolute energies of the CHF responses, derived from the grayscale version of the original color image. Final detection of the informative frames is obtained by using threshold operation on the extracted regions. An experiment with 20,558 frames from the three videos shows the excellent average detection accuracy (96.75%) by the proposed method, when compared with the Gabor based- (74.29%) and discrete wavelet based features (62.21%).
Huang, Bei-Bei; Li, Guo-Feng; Luo, Jing-Hui; Duan, Lian; Nobuaki, Kishimoto; Akira, Yamamoto
2008-01-01
AIM: To investigate the permeability characteristics of rebamipide across intestinal mucosa, and examine the effects of some absorption enhancers on the permeability across the colonic tissue. Another purpose is to demonstrate the colon-specific delivery of rebamipide with or without absorption enhancers using chitosan capsule as a carrier. METHODS: The permeability of rebamipide was evaluated using an in vitro diffusion chamber system, and the effects of some absorption enhancers on the permeability via colon were further investigated. The release of rebamipide from chitosan or gelatin capsule was studied by Japan Pharmacopoeia rotating basket method. The colonic and plasma concentrations were analyzed by high performance liquid chromatography (HPLC) to evaluate colon-targeting action after oral administration of various dosage forms, and rebamipide with absorption enhancers in chitosan dosage forms. RESULTS: The permeability of rebamipide across the jejunal or ileal membranes was higher than the colonic membranes. Both sodium laurate (C12) and labrasol significantly increased permeability across the colon membranes. On the other hand, the release of rebamipide from chitosan capsule was less than 10% totally within 6 h. The area under concentration-time profile of drug in the colon mucosa using chitosan capsules (AUCLI, 1 6011.2 ng·h/g) was 2.5 times and 4.4 times greater than using gelatin capsules and CMC suspension, respectively. Meanwhile, the area under concentration-time profile of drug in the plasma (AUCPL) was 1016.0 ng·h/mL for chitosan capsule, 1887.9 ng·h/mL for CMC suspension p and 2163.5 ng·h/mL for gelatin capsule. Overall, both AUCLI and AUCPL were increased when C12 was co-administrated, but the increase of AUCLI was much greater; the drug delivery index (DDI) was more than 1 compared with simple chitosan capsule group. CONCLUSION: There was a regional difference in the permeability of Rebamipide across the jejunum, ileum and the colon, and passive diffusion seems to be one of the major transport mechanisms of rebamipide. Absorption enhancers can increase the permeability of rebamipide across the colon tissue significantly. In addition, chitosan capsule may be a useful carrier to deliver rebamipide to the colon specifically and the co-administration of C12 with rebamipide may also be very useful in local treatment. PMID:18756602
Endoscopy: MedlinePlus Health Topic
... What Is Endoscopy? (American Cancer Society) Also in Spanish Related Issues Ensuring the Safety of Your Endoscopic Procedure (American Society for Gastrointestinal Endoscopy) Also in Spanish Sedation for Your Endoscopy (American College of Gastroenterology) ...
Less Is More: A Minimalist Approach to Endoscopy.
Shaheen, Nicholas J; Fennerty, M Brian; Bergman, Jacques J
2018-05-01
A substantial literature documents inappropriate usage of gastrointestinal endoscopy in a variety of clinical settings. Overusage of endoscopy appears to be common, and 30% or more of procedures performed in some clinical settings have questionable indications. The potential reasons for overuse of endoscopy are multiple, and include cancer phobia, fear of medical malpractice litigation, profit motive, the investigation of "incidentalomas" found on other imaging, and underappreciation of the delayed harms of endoscopy, among other reasons. Clinical guidelines, which should limit overuse of endoscopy, may instead serve to promote it, if authors opt to be "conservative," recommending endoscopy in situations of unclear utility. Several strategies may decrease overuse of endoscopy, including careful attention to risk stratification when choosing patients to screen, adherence to guidelines for surveillance intervals for colonoscopy, the use of quality indicators to identify outliers in endoscopy utilization, and education on appropriate indications and the risks of overuse at the medical student, residency, and fellowship levels. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.
Remák, E; Brown, R E; Yuen, C; Robinson, A
2005-10-01
Gastro-oesophageal reflux disease (GORD) is a recurring condition with many patients requiring long-term maintenance therapy. Therefore initial choice of treatment has long-term cost implications. The aim was to compare the costs and effectiveness of treatment of GORD the (unconfirmed by endoscopy) with seven proton pump inhibitors (PPIs: esomeprazole, lansoprazole (capsules and oro-dispersible tablets), omeprazole (generic and branded), pantoprazole and rabeprazole), over one year. A treatment model was developed of 13 interconnected Markov models incorporating acute treatment of symptoms, long-term therapy and subsequent decisions to undertake endoscopy to confirm diagnosis. Patients were allowed to stop treatment or to receive maintenance treatment either continuously or on-demand depending on response to therapy. Long-term dosing schedule (high dose or step-down dose) was based on current market data. Efficacy of treatments was based on clinical trials and follow-up studies, while resource use patterns were determined by a panel of physicians. The model predicts total expected annual costs, number of symptom-free days and quality-adjusted life-years (QALY). Generic omeprazole and rabeprazole dominated (i.e. cost less and resulted in more symptom-free days and higher QALY gains) the other PPIs. Rabeprazole had a favourable cost-effectiveness ratio of 3.42 pounds per symptom-free day and 8308 pounds/quality-adjusted life-year gained when compared with generic omeprazole. Rabeprazole remained cost-effective independent of choice of maintenance treatment (i.e. proportion of patients remaining on continuous treatment versus on-demand treatment). Economic models provide a useful framework to evaluate PPIs in realistic clinical scenarios. Our findings show that rabeprazole is cost-effective for the treatment of GORD.
Micro-intestinal robot with wireless power transmission: design, analysis and experiment.
Shi, Yu; Yan, Guozheng; Chen, Wenwen; Zhu, Bingquan
2015-11-01
Video capsule endoscopy is a useful tool for noninvasive intestinal detection, but it is not capable of active movement; wireless power is an effective solution to this problem. The research in this paper consists of two parts: the mechanical structure which enables the robot to move smoothly inside the intestinal tract, and the wireless power supply which ensures efficiency. First, an intestinal robot with leg architectures was developed based on the Archimedes spiral, which mimics the movement of an inchworm. The spiral legs were capable of unfolding to an angle of approximately 155°, which guaranteed stability of clamping, consistency of surface pressure, and avoided the risk of puncturing the intestinal tract. Secondly, the necessary power to operate the robot was far beyond the capacity of button batteries, so a wireless power transmission (WPT) platform was developed. The design of the platform focused on power transfer efficiency and frequency stability. In addition, the safety of human tissue in the alternating electromagnetic field was also taken into consideration. Finally, the assembled robot was tested and verified with the use of the WPT platform. In the isolated intestine, the robot system successfully traveled along the intestine with an average speed of 23 mm per minute. The obtained videos displayed a resolution of 320 × 240 and a transmission rate of 30 frames per second. The WPT platform supplied up to 500 mW of energy to the robot, and achieved a power transfer efficiency of 12%. It has been experimentally verified that the intestinal robot is safe and effective as an endoscopy tool, for which wireless power is feasible. Proposals for further improving the robot and wireless power supply are provided later in this paper. Copyright © 2015 Elsevier Ltd. All rights reserved.
Makris, M; Federici, A B; Mannucci, P M; Bolton-Maggs, P H B; Yee, T T; Abshire, T; Berntorp, E
2015-05-01
Recurrent gastrointestinal bleeding is one of the most challenging complications encountered in the management of patients with von Willebrand disease (VWD). The commonest cause is angiodysplasia, but often no cause is identified due to the difficulty in making the diagnosis. The optimal treatment to prevent recurrences remains unknown. We performed a retrospective study of VWD patients with occult or angiodysplastic bleeding within the setting of the von Willebrand Disease Prophylaxis Network (VWD PN) to describe diagnostic and treatment strategies. Centres participating in the VWD PN recruited subjects under their care with a history of congenital VWD and gastrointestinal (GI) bleeding due to angiodysplasia, or cases in which the cause was not identified despite investigation. Patients with acquired von Willebrand syndrome or those for whom the GI bleeding was due to another cause were excluded. Forty-eight patients from 18 centres in 10 countries were recruited. Seven individuals had a family history of GI bleeding and all VWD types except 2N were represented. Angiodysplasia was confirmed in 38%, with video capsule endoscopy and GI tract endoscopies being the most common methods of making the diagnosis. Recurrent GI bleeding in VWD is associated with significant morbidity and required hospital admission on up to 30 occasions. Patients were treated with multiple pharmacological agents with prophylactic von Willebrand factor concentrate being the most efficient in preventing recurrence of the GI bleeding. The diagnosis and treatment of recurrent GI bleeding in congenital VWD remains challenging and is associated with significant morbidity. Prophylactic treatment with von Willebrand factor concentrate was the most effective method of preventing recurrent bleeding but its efficacy remains to be confirmed in a prospective study. © 2014 John Wiley & Sons Ltd.
Twardy, Vanessa; Becker, Felix; Geyer, Christiane; Schwegmann, Katrin; Mohr, Annika; Faust, Andreas
2018-01-01
Background Disturbance of intestinal wound closure leads to insufficient anastomotic healing and is associated with considerable morbidity following colorectal resections. Matrix metalloproteinases (MMPs) play a crucial role in regulation of wound closure. Here fluorescence endoscopy was evaluated for assessment of MMP-2/-9 expression during failed intestinal anastomotic healing. Methods Distal colonic anastomoses were performed as a model for disturbed healing in 36 Balb/c mice. Healing was evaluated endoscopically, macroscopically, and histologically after 1, 3 and 5 days. For detection of MMP-2/-9 expression fluorescence endoscopy (FE) was used following i.v.-administration of a Cy5.5-labeled MMP-2/-9 specific tracer. FE was complemented by quantification of the fluorescence signal using the MS-FX PRO Optical Imaging System. An overall leakage score was calculated and correlated with the results of FE. Results With increasing incidence of anastomotic leakage from POD1 (17%) to POD5 (83%) the uptake of the MMP tracer gradually increased (signal-to-noise ratio (SNR), POD1: 17.91 ± 1.251 vs. POD3: 30.56 ± 3.03 vs. POD5: 44.8 ± 4.473, P<0.0001). Mice with defective anastomotic healing showed significantly higher uptake compared to non-defective (SNR: 37.37± 3.63 vs. 26.16± 3.635, P = 0.0369). White light endoscopy and FE allowed evaluation of anastomotic healing and visualization of mucosal MMPs in vivo. Using FE based detection of MMPs in the anastomosis, an overall positive predictive value of 71.4% and negative predictive value of 66.6% was calculated for detection of anastomotic leakage. Conclusion During disturbed anastomotic healing increased expression of MMP-2/-9 was observed in the anastomotic tissue. Fluorescence endoscopy for detection of MMP-2/-9 during the healing process might be a promising tool for early identification of anastomotic leakage. PMID:29566031
Neumann, Philipp-Alexander; Twardy, Vanessa; Becker, Felix; Geyer, Christiane; Schwegmann, Katrin; Mohr, Annika; Faust, Andreas; Lenz, Philipp; Rijcken, Emile
2018-01-01
Disturbance of intestinal wound closure leads to insufficient anastomotic healing and is associated with considerable morbidity following colorectal resections. Matrix metalloproteinases (MMPs) play a crucial role in regulation of wound closure. Here fluorescence endoscopy was evaluated for assessment of MMP-2/-9 expression during failed intestinal anastomotic healing. Distal colonic anastomoses were performed as a model for disturbed healing in 36 Balb/c mice. Healing was evaluated endoscopically, macroscopically, and histologically after 1, 3 and 5 days. For detection of MMP-2/-9 expression fluorescence endoscopy (FE) was used following i.v.-administration of a Cy5.5-labeled MMP-2/-9 specific tracer. FE was complemented by quantification of the fluorescence signal using the MS-FX PRO Optical Imaging System. An overall leakage score was calculated and correlated with the results of FE. With increasing incidence of anastomotic leakage from POD1 (17%) to POD5 (83%) the uptake of the MMP tracer gradually increased (signal-to-noise ratio (SNR), POD1: 17.91 ± 1.251 vs. POD3: 30.56 ± 3.03 vs. POD5: 44.8 ± 4.473, P<0.0001). Mice with defective anastomotic healing showed significantly higher uptake compared to non-defective (SNR: 37.37± 3.63 vs. 26.16± 3.635, P = 0.0369). White light endoscopy and FE allowed evaluation of anastomotic healing and visualization of mucosal MMPs in vivo. Using FE based detection of MMPs in the anastomosis, an overall positive predictive value of 71.4% and negative predictive value of 66.6% was calculated for detection of anastomotic leakage. During disturbed anastomotic healing increased expression of MMP-2/-9 was observed in the anastomotic tissue. Fluorescence endoscopy for detection of MMP-2/-9 during the healing process might be a promising tool for early identification of anastomotic leakage.
Yagi, Kazuyoshi; Saka, Akiko; Nozawa, Yujiro; Nakamura, Atsuo
2014-04-01
To reduce the incidence of metachronous gastric carcinoma after endoscopic resection of early gastric cancer, Helicobacter pylori eradication therapy has been endorsed. It is not unusual for such patients to be H. pylori negative after eradication or for other reasons. If it were possible to predict H. pylori status using endoscopy alone, it would be very useful in clinical practice. To clarify the accuracy of endoscopic judgment of H. pylori status, we evaluated it in the stomach after endoscopic submucosal dissection (ESD) of gastric cancer. Fifty-six patients treated by ESD were enrolled. The diagnostic criteria for H. pylori status by conventional endoscopy and narrow-band imaging (NBI)-magnifying endoscopy were decided, and H. pylori status was judged by two endoscopists. Based on the H. pylori stool antigen test as a diagnostic gold standard, conventional endoscopy and NBI-magnifying endoscopy were compared for their sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Interobserver agreement was assessed in terms of κ value. Interobserver agreement was moderate (0.56) for conventional endoscopy and substantial (0.77) for NBI-magnifying endoscopy. The sensitivity, specificity, PPV, and NPV were 0.79, 0.52, 0.70, and 0.63 for conventional endoscopy and 0.91, 0.83, 0.88, and 0.86 for NBI-magnifying endoscopy, respectively. Prediction of H. pylori status using NBI-magnifying endoscopy is practical, and interobserver agreement is substantial. © 2013 John Wiley & Sons Ltd.
Matharoo, Manmeet; Haycock, Adam; Sevdalis, Nick; Thomas-Gibson, Siwan
2014-12-14
To investigate whether novel, non-technical skills training for Bowel Cancer Screening (BCS) endoscopy teams enhanced patient safety knowledge and attitudes. A novel endoscopy team training intervention for BCS teams was developed and evaluated as a pre-post intervention study. Four multi-disciplinary BCS teams constituting BCS endoscopist(s), specialist screening practitioners, endoscopy nurses and administrative staff (A) from English BCS training centres participated. No patients were involved in this study. Expert multidisciplinary faculty delivered a single day's training utilising real clinical examples. Pre and post-course evaluation comprised participants' patient safety awareness, attitudes, and knowledge. Global course evaluations were also collected. Twenty-three participants attended and their patient safety knowledge improved significantly from 43%-55% (P ≤ 0.001) following the training intervention. 12/41 (29%) of the safety attitudes items significantly improved in the areas of perceived patient safety knowledge and awareness. The remaining safety attitude items: perceived influence on patient safety, attitudes towards error management, error management actions and personal views following an error were unchanged following training. Both qualitative and quantitative global course evaluations were positive: 21/23 (91%) participants strongly agreed/agreed that they were satisfied with the course. Qualitative evaluation included mandating such training for endoscopy teams outside BCS and incorporating team training within wider endoscopy training. Limitations of the study include no measure of increased patient safety in clinical practice following training. A novel comprehensive training package addressing patient safety, non-technical skills and adverse event analysis was successful in improving multi-disciplinary teams' knowledge and safety attitudes.
Matharoo, Manmeet; Haycock, Adam; Sevdalis, Nick; Thomas-Gibson, Siwan
2014-01-01
AIM: To investigate whether novel, non-technical skills training for Bowel Cancer Screening (BCS) endoscopy teams enhanced patient safety knowledge and attitudes. METHODS: A novel endoscopy team training intervention for BCS teams was developed and evaluated as a pre-post intervention study. Four multi-disciplinary BCS teams constituting BCS endoscopist(s), specialist screening practitioners, endoscopy nurses and administrative staff (A) from English BCS training centres participated. No patients were involved in this study. Expert multidisciplinary faculty delivered a single day’s training utilising real clinical examples. Pre and post-course evaluation comprised participants’ patient safety awareness, attitudes, and knowledge. Global course evaluations were also collected. RESULTS: Twenty-three participants attended and their patient safety knowledge improved significantly from 43%-55% (P ≤ 0.001) following the training intervention. 12/41 (29%) of the safety attitudes items significantly improved in the areas of perceived patient safety knowledge and awareness. The remaining safety attitude items: perceived influence on patient safety, attitudes towards error management, error management actions and personal views following an error were unchanged following training. Both qualitative and quantitative global course evaluations were positive: 21/23 (91%) participants strongly agreed/agreed that they were satisfied with the course. Qualitative evaluation included mandating such training for endoscopy teams outside BCS and incorporating team training within wider endoscopy training. Limitations of the study include no measure of increased patient safety in clinical practice following training. CONCLUSION: A novel comprehensive training package addressing patient safety, non-technical skills and adverse event analysis was successful in improving multi-disciplinary teams’ knowledge and safety attitudes. PMID:25516665
Helicobacter pylori eradication and histopathological esophagitis in dyspeptic patients.
Amini, Mohsen; Karbasi, Ashraf; Khedmat, Hossein; Jeihounian, Mojgan
2010-01-01
The association of Helicobacterpylori with peptic ulcer disease, atrophic gastritis, gastric adenocarcinoma, MALT (mucosa associated lymphoid tissue) lymphoma is well recognized. This study was conducted to see whether there was any relation between H. pylori eradication and reflux esophagitis in Iran. Eligible dyspeptic patients referred to Gastroenterology clinic in Baqiyatollah hospital were endoscopied and evaluated for endoscopic and pathologic esophagitis and the H. pylori infection status was determined by rapid urease test. H. pylori infection was treated by an anti H. pylori drug regimen and successfully eradicated patients according to negative C14 urea breath test were followed and re-endoscopy was performed 6-9 months after the end of treatment. From 175 eligible patients, 54% were H. pylori positive, 68 of them (72%) had successful H.P. eradication and 64 patients completed the follow-up. The rate of histopathologic inflammatory esophagitis was higher in second endoscopy, compared with that of first endoscopy, i.e., before H. pylori eradication (75% vs 40.6%) (p < 0.05). Progression of pathological esophagitis was seen in 56.3% of patients between the two endoscopic evaluations in spite of no change in clinical and endoscopic findings. There were no significant differences in dietary and smoking habits and body weights on re-endoscopy session compared with that of the first endoscopy visit (p > 0.05). This study suggests that H. pylori eradication in dyspeptic patients may lead to increased frequency of histopathological esophagitis. Hence, In patients presenting with symptoms of dyspepsia, a cautious approach should be exercised if H. pylori eradication is being contemplated.
Perforation following colorectal endoscopy: what happens beyond the endoscopy suite?
Tam, Michael S; Abbas, Maher A
2013-01-01
The risk factors for perforation from colorectal endoscopy have been well studied, but little is known about clinical outcomes beyond the immediate event. To evaluate short- and long-term outcomes of iatrogenic colorectal perforation following colorectal endoscopy. Retrospective review over 16 years at a single tertiary care institution. Treatment interventions, morbidity and mortality rates, hospital length of stay, stoma closure rate, and long-term complications. Of 132,259 colorectal endoscopies, 26 patients (0.02%) had a perforation (54% males; mean age, 67 years). The rectosigmoid colon was the most common site of perforation (65%). Thirty-eight percent of the perforations were recognized at the time of procedure, 31% presented within 24 hours, and 31% presented beyond 24 hours. Operative repair was undertaken in 85% of the patients, and 15% were managed with inpatient hospital observation. Primary repair was performed in 68% (defunctioning stoma in 18%). Mean hospital length of stay was 10.1 days. The overall postoperative complications rate was 55%, and wound complications were noted in 45%. The 30-day mortality rate was 19%. No death was observed beyond the first month. American Society of Anesthesiologists physical status Classes 3 and 4 were associated with mortality (p = 0.004). Of 7 patients who received a stoma, only 2 patients (29%) had stoma reversal. Long-term complications included incisional hernia (10%) and small-bowel obstruction (5%). Perforation following colorectal endoscopy was uncommon in this study but was associated with significant morbidity and mortality. An increased risk of death was noted with higher American Society of Anesthesiologists physical status class.
Endoscopy and antiplatelet agents. European Society of Gastrointestinal Endoscopy (ESGE) Guideline.
Boustière, C; Veitch, A; Vanbiervliet, G; Bulois, P; Deprez, P; Laquiere, A; Laugier, R; Lesur, G; Mosler, P; Nalet, B; Napoleon, B; Rembacken, B; Ajzenberg, N; Collet, J P; Baron, T; Dumonceau, J-M
2011-05-01
With the increasing use of antiplatelet agents (APA), their management during the periendoscopic period has become a more common and more difficult problem. The increase in use is due to the availability of new drugs and the widespread use of drug-eluting coronary stents. Acute coronary syndromes can occur when APA therapy is withheld for noncardiovascular interventions. Guidelines about APA management during the periendoscopic period are traditionally based on assessments of the procedure-related risk of bleeding and the risk of thrombosis if APA are stopped. New data allow better assessment of these risks, of the necessary duration of APA discontinuation before endoscopy, of the use of alternative procedures (mostly for endoscopic retrograde cholangiopancreatography [ERCP]), and of endoscopic methods that can be used to prevent bleeding (following colonic polypectomy). This guideline makes graded, evidence-based, recommendations for the management of APA for all currently performed endoscopic procedures. A short summary and two tables are included for quick reference. © Georg Thieme Verlag KG Stuttgart · New York.
[Microbiological investigation of endoscopes at Brest Hospital over a period from 2007 to 2009].
Saliou, P; Garlantézec, R; Baron, R; Quiot, J-J; Cholet, F; Le Floch, M-F; Lejeune, B
2011-04-01
The aim of this study is to evaluate the quality of disinfection of endoscopes at Brest hospital over a period from 2007 to 2009. Retrospective study of microbiological investigations of endoscopes done at Brest hospital from 2007 to 2009. The interpretation of the microbiological investigations is based on the recommendations of the Comité technique national des infections nosocomiales et infections liées aux soins (CTINILS) of 2007. Most of the controls realized over the period deal with gastroenterological endoscopes (63.4 %) and bronchial endoscopes (21.8 %). Most of the controls (66.8 %) are conformed to the target level. Only 26.7 % of the controls get the level of action. Globally, the rate of level of action significantly increases (p=0.004) from 2007 (21.2 %) to 2009 (35.6 %). This increase is relatively important in gastroenterology endoscopy (46.8 % in 2009 versus 24.1 % in 2007) whereas the rate decreases in bronchial endoscopy (14.8 % in 2009 versus 25.9 % in 2007). In gastroenterological endoscopy, rates vary with the type of endoscopes and the context of controls, but there is no significant difference between manual disinfection and automated disinfection. The most frequent germ found in gastroenterological and bronchial endoscopies is Pseudomonas aeruginosa. Our results show that it is very difficult to insure a perfect disinfection of endoscopes. Difficulties met are certainly related with the complexity of the endoscopes and of the techniques of disinfection. Infections of patients are very infrequent in endoscopy, which takes the question of the pertinence of the threshold used for microbiological investigations. Copyright © 2010. Published by Elsevier SAS.
García-Rodas, Rocío; Casadevall, Arturo; Rodríguez-Tudela, Juan Luís; Cuenca-Estrella, Manuel; Zaragoza, Oscar
2011-01-01
We have studied infection of Cryptococcus neoformans in the non-vertebrate host Galleria mellonella with particular interest in the morphological response of the yeast. Inoculation of C. neoformans in caterpillars induced a capsule-independent increase in haemocyte density 2 h after infection. C. neoformans manifested a significant increase in capsule size after inoculation into the caterpillar. The magnitude of capsule increase depended on the temperature, being more pronounced at 37°C than at 30°C, which correlated with an increased virulence of the fungus and reduced phagocytosis at 37°C. Capsule enlargement impaired phagocytosis by haemocytes. Incubation of the yeast in G. mellonella extracts also resulted in capsule enlargement, with the polar lipidic fraction having a prominent role in this effect. During infection, the capsule decreased in permeability. A low proportion of the cells (<5%) recovered from caterpillars measured more than 30 µm and were considered giant cells. Giant cells recovered from mice were able to kill the caterpillars in a manner similar to regular cells obtained from in vivo or grown in vitro, establishing their capacity to cause disease. Our results indicate that the morphological transitions exhibited by C. neoformans in mammals also occur in a non-vertebrate host system. The similarities in morphological transitions observed in different animal hosts and in their triggers are consistent with the hypothesis that the cell body and capsular responses represent an adaptation of environmental survival strategies to pathogenesis. PMID:21915338
Factors influencing the adequacy of microencapsulation of rat pancreatic islets.
De Vos, P; De Haan, B; Wolters, G H; Van Schilfgaarde, R
1996-10-15
The observation that only a portion of all alginate-polylysine microcapsules are overgrown after implantation suggests that physical imperfections of individual capsules, rather than the chemical composition of the material applied, are responsible for inducing insufficient biocompatibility and thereby fibrotic overgrowth of those capsules. We recently developed a lectin binding assay that allows for quantifying the portion of inadequately encapsulated islets, and demonstrated that inadequately encapsulated islets induce a fibrotic response associated with graft failure. The present study investigates factors influencing the adequacy of encapsulation of pancreatic islets. We applied our lectin binding assay and found that the number of inadequate, and particularly incomplete, capsules is influenced by the following factors. (1) A capsule diameter of 800 micrometers is associated with a lower percentage of inadequate capsules than smaller (500 micrometers and 600 micrometers) or larger (1800 micrometers) capsules. (2) A high rather than low guluronic acid content of the alginate is associated with a lower percentage of inadequate capsules. This can be explained, at least in part, by smaller ranges of swelling and subsequent shrinkage during the encapsulation procedure. (3) An increase in viscosity caused by applying a higher alginate concentration compensates for a low guluronic acid content. This effect of increased viscosity cannot be explained by a reduced range of swelling and shrinkage during the encapsulation procedure. We conclude that alginates with a high guluronic acid content and a viscosity near the filtration limit are preferable in order to minimize the number of inadequate capsules.
Brochu, Alice B.W.; Matthys, Oriane B.; Craig, Stephen L.; Reichert, William M.
2014-01-01
The tissue adhesive 2-octyl cyanoacrylate (OCA) was encapsulated in polyurethane microshells and incorporated into bone cement to form a catalyst free, self-healing bone cement comprised of all clinically approved components. The bending strength, modulus, and fatigue lifetime were investigated in accordance with ASTM and ISO standards for the testing of PMMA bone cement. The bending strength of bone cement specimens decreased with increasing wt% capsules content for capsules without or with OCA, with specimens of < 5 wt% capsule content showing minimal effect. In contrast, bone cement bending modulus was insensitive to capsule content. Load controlled fatigue testing was performed in air at room temperature on capsule free bone cement (0 wt%), bone cement with 5 wt% OCA-free capsules (5 wt% No OCA), and 5 wt% OCA-containing capsules (5 wt% OCA). Specimens were tested at a frequency of 5 Hz at maximum stresses of 90%, 80%, 70% and 50% of each specimen's bending strength until failure. The 5 wt% OCA exhibited significant self-healing at 70% and 50% of its reference strength (p < 0.05). Fatigue testing of all three specimen types in air at 22 MPa (50% of reference strength of the 5 wt% OCA specimens) showed that the cycles to failure of OCA-containing specimens was increased by two-fold compared to the OCA-free and capsule-free specimens. This study represents the first demonstration of dynamic, catalyst-free self-healing in a biomaterial formulation. PMID:24825796
Nitrogen Source-Dependent Capsule Induction in Human-Pathogenic Cryptococcus Species
Frazzitta, Aubrey E.; Vora, Haily; Price, Michael S.; Tenor, Jennifer L.; Betancourt-Quiroz, Marisol; Toffaletti, Dena L.; Cheng, Nan
2013-01-01
Cryptococcus neoformans and C. gattii cause meningoencephalitis and are an increasing human health threat. These pathogenic Cryptococcus species are neurotropic and persist in the cerebrospinal fluid (CSF) of the mammalian host during infection. In order to survive in the host, pathogenic fungi must procure nutrients, such as carbon and nitrogen, from the CSF. To enhance our understanding of nutrient acquisition during central nervous system infection by Cryptococcus species, we examined the utilization of nitrogen sources available in CSF. We screened for the growth and capsule production of 817 global environmental and clinical isolates on various sources of nitrogen. Both environmental and clinical strains grew robustly on uric acid, Casamino Acids, creatinine, and asparagine as sole nitrogen sources. Urea induced the greatest magnitude of capsule induction. This induction was greater in Cryptococcus gattii than in C. neoformans. We confirmed the ability of nonpreferred nitrogen sources to increase capsule production in pathogenic species of Cryptococcus. Since urea is metabolized to ammonia and CO2 (a known signal for capsule induction), we examined urea metabolism mutants for their transcriptional response to urea regarding capsule production. The transcriptional profile of C. neoformans under urea-supplemented conditions revealed both similar and unique responses to other capsule-inducing conditions, including both intra- and extracellular urea utilization. As one of the most abundant nitrogen sources in the CSF, the ability of Cryptococcus to import urea and induce capsule production may substantially aid this yeast's survival and propagation in the host. PMID:23975889
Nitrogen source-dependent capsule induction in human-pathogenic cryptococcus species.
Frazzitta, Aubrey E; Vora, Haily; Price, Michael S; Tenor, Jennifer L; Betancourt-Quiroz, Marisol; Toffaletti, Dena L; Cheng, Nan; Perfect, John R
2013-11-01
Cryptococcus neoformans and C. gattii cause meningoencephalitis and are an increasing human health threat. These pathogenic Cryptococcus species are neurotropic and persist in the cerebrospinal fluid (CSF) of the mammalian host during infection. In order to survive in the host, pathogenic fungi must procure nutrients, such as carbon and nitrogen, from the CSF. To enhance our understanding of nutrient acquisition during central nervous system infection by Cryptococcus species, we examined the utilization of nitrogen sources available in CSF. We screened for the growth and capsule production of 817 global environmental and clinical isolates on various sources of nitrogen. Both environmental and clinical strains grew robustly on uric acid, Casamino Acids, creatinine, and asparagine as sole nitrogen sources. Urea induced the greatest magnitude of capsule induction. This induction was greater in Cryptococcus gattii than in C. neoformans. We confirmed the ability of nonpreferred nitrogen sources to increase capsule production in pathogenic species of Cryptococcus. Since urea is metabolized to ammonia and CO(2) (a known signal for capsule induction), we examined urea metabolism mutants for their transcriptional response to urea regarding capsule production. The transcriptional profile of C. neoformans under urea-supplemented conditions revealed both similar and unique responses to other capsule-inducing conditions, including both intra- and extracellular urea utilization. As one of the most abundant nitrogen sources in the CSF, the ability of Cryptococcus to import urea and induce capsule production may substantially aid this yeast's survival and propagation in the host.
Imaging of High-Z doped, Imploded Capsule Cores
NASA Astrophysics Data System (ADS)
Prisbrey, Shon T.; Edwards, M. John; Suter, Larry J.
2006-10-01
The ability to correctly ascertain the shape of imploded fusion capsules is critical to be able to achieve the spherical symmetry needed to maximize the energy yield of proposed fusion experiments for the National Ignition Facility. Implosion of the capsule creates a hot, dense core. The introduction of a high-Z dopant into the gas-filled core of the capsule increases the amount of bremsstrahlung radiation produced in the core and should make the imaging of the imploded core easier. Images of the imploded core can then be analyzed to ascertain the symmetry of the implosion. We calculate that the addition of Ne gas into a deuterium gas core will increase the amount of radiation emission while preserving the surrogacy of the radiation and hydrodynamics in the indirect drive NIF hohlraum in the proposed cryogenic hohlraums. The increased emission will more easily enable measurement of asymmetries and tuning of the implosion.
Simultaneous functional photoacoustic and ultrasonic endoscopy of internal organs in vivo.
Yang, Joon-Mo; Favazza, Christopher; Chen, Ruimin; Yao, Junjie; Cai, Xin; Maslov, Konstantin; Zhou, Qifa; Shung, K Kirk; Wang, Lihong V
2012-08-01
At present, clinicians routinely apply ultrasound endoscopy in a variety of interventional procedures that provide treatment solutions for diseased organs. Ultrasound endoscopy not only produces high-resolution images, but also is safe for clinical use and broadly applicable. However, for soft tissue imaging, its mechanical wave-based image contrast fundamentally limits its ability to provide physiologically specific functional information. By contrast, photoacoustic endoscopy possesses a unique combination of functional optical contrast and high spatial resolution at clinically relevant depths, ideal for imaging soft tissues. With these attributes, photoacoustic endoscopy can overcome the current limitations of ultrasound endoscopy. Moreover, the benefits of photoacoustic imaging do not come at the expense of existing ultrasound functions; photoacoustic endoscopy systems are inherently compatible with ultrasound imaging, thereby enabling multimodality imaging with complementary contrast. Here we present simultaneous photoacoustic and ultrasonic dual-mode endoscopy and show its ability to image internal organs in vivo, thus illustrating its potential clinical application.
Simultaneous functional photoacoustic and ultrasonic endoscopy of internal organs in vivo
Yang, Joon-Mo; Favazza, Christopher; Chen, Ruimin; Yao, Junjie; Cai, Xin; Maslov, Konstantin; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.
2013-01-01
Presently, clinicians routinely apply ultrasound endoscopy in a variety of interventional procedures which provide treatment solutions for diseased organs. Ultrasound endoscopy not only produces high resolution images, it is also safe for clinical use and broadly applicable. However, for soft tissue imaging, its mechanical wave-based image contrast fundamentally limits its ability to provide physiologically-specific functional information. By contrast, photoacoustic endoscopy possesses a unique combination of functional optical contrast and high spatial resolution at clinically-relevant depths, ideal for soft tissue imaging. With these attributes, photoacoustic endoscopy can overcome the current limitations of ultrasound endoscopy. Moreover, the benefits of photoacoustic imaging do not come at the expense of existing ultrasound functions; photoacoustic endoscopy systems are inherently compatible with ultrasound imaging, enabling multi-modality imaging with complementary contrast. Here, we present simultaneous photoacoustic and ultrasonic dual-mode endoscopy and demonstrate its ability to image internal organs in vivo, illustrating its potential clinical application. PMID:22797808
Multiple internalization pathways of polyelectrolyte multilayer capsules into mammalian cells.
Kastl, Lena; Sasse, Daniel; Wulf, Verena; Hartmann, Raimo; Mircheski, Josif; Ranke, Christiane; Carregal-Romero, Susana; Martínez-López, José Antonio; Fernández-Chacón, Rafael; Parak, Wolfgang J; Elsasser, Hans-Peter; Rivera Gil, Pilar
2013-08-27
Polyelectrolyte multilayer (PEM) capsules are carrier vehicles with great potential for biomedical applications. With the future aim of designing biocompatible, effective therapeutic delivery systems (e.g., for cancer), the pathway of internalization (uptake and fate) of PEM capsules was investigated. In particular the following experiments were performed: (i) the study of capsule co-localization with established endocytic markers, (ii) switching-off endocytotic pathways with pharmaceutical/chemical inhibitors, and (iii) characterization and quantification of capsule uptake with confocal and electron microscopy. As result, capsules co-localized with lipid rafts and with phagolysosomes, but not with other endocytic vesicles. Chemical interference of endocytosis with chemical blockers indicated that PEM capsules enter the investigated cell lines through a mechanism slightly sensitive to electrostatic interactions, independent of clathrin and caveolae, and strongly dependent on cholesterol-rich domains and organelle acidification. Microscopic characterization of cells during capsule uptake showed the formation of phagocytic cups (vesicles) to engulf the capsules, an increased number of mitochondria, and a final localization in the perinuclear cytoplasma. Combining all these indicators we conclude that PEM capsule internalization in general occurs as a combination of different sequential mechanisms. Initially, an adsorptive mechanism due to strong electrostatic interactions governs the stabilization of the capsules at the cell surface. Membrane ruffling and filopodia extensions are responsible for capsule engulfing through the formation of a phagocytic cup. Co-localization with lipid raft domains activates the cell to initiate a lipid-raft-mediated macropinocytosis. Internalization vesicles are very acidic and co-localize only with phagolysosome markers, excluding caveolin-mediated pathways and indicating that upon phagocytosis the capsules are sorted to heterophagolysosomes.
Kuramoto, Takanori; Umegaki, Eiji; Nouda, Sadaharu; Narabayashi, Ken; Kojima, Yuichi; Yoda, Yukiko; Ishida, Kumi; Kawakami, Ken; Abe, Yosuke; Takeuchi, Toshihisa; Inoue, Takuya; Murano, Mitsuyuki; Tokioka, Satoshi; Higuchi, Kazuhide
2013-05-14
Proton-pump inhibitors such as omeprazole are a standard treatment to prevent non-steroidal anti-inflammatory drug-induced upper gastrointestinal mucosal injuries. However, it is unclear which drugs may protect against all NSAID-induced digestive-tract injuries. Here, we compare the efficacy of the gastromucoprotective drug irsogladine with omeprazole in preventing NSAID-induced esophagitis, peptic ulcers, and small-intestinal mucosal injury in healthy subjects. Thirty-two healthy volunteers were assigned to an irsogladine group (Group I; n = 16) receiving diclofenac sodium 75 mg and irsogladine 4 mg daily for 14 days, or an omeprazole group (Group O; n = 16) receiving diclofenac sodium 75 mg and omeprazole 10 mg daily for 14 days. Esophagitis and peptic ulcers were evaluated by esophagogastroduodenoscopy and small-intestinal injuries by capsule endoscopy, fecal calprotectin, and fecal occult blood before and after treatment. There was no significant difference between Group I and Group O with respect to the change in lesion score in the esophagus, stomach, and duodenum before and after treatment.NSAID treatment significantly increased the number of small intestinal mucosal breaks per subject by capsule endoscopic evaluation, from a basal level of 0.1 ± 0.3 up to 1.9 ± 2.0 lesions in Group O (p = 0.0002). In contrast, there were no significant changes in the mean number of mucosal breaks before and after co-treatment in Group I (0.3 ± 0.8 to 0.5 ± 0.7, p = 0.62), and the between-group difference was significant (p = 0.0040). Fecal calprotectin concentration, when the concentration before treatment was defined as 1, was significantly increased both in Group O (from 1.0 ± 0.0 to 18.1 ± 37.1, p = 0.0002) and Group I (from 1.0 ± 0.0 to 6.0 ± 11.1, p = 0.0280); the degree of increase in Group O was significantly higher compared with that in Group I (p<0.05). In addition, fecal occult blood levels increased significantly in Group O (p = 0.0018), but there was no change in Group I (p = 1.0), and the between-group difference was significant (p = 0.0031). Irsogladine protected against NSAID-induced mucosal injuries throughout the gastrointestinal tract, from esophagus to small intestine, significantly better than omeprazole. This study was registered in the UMIN Clinical Trials Registry (Registry ID number; UMIN000008114).
Efficiency of upper gastrointestinal endoscopy in pediatric surgical practice
Temiz, Abdulkerim
2015-01-01
After the introduction of flexible fiber optic endoscopy to pediatric gastroenterology in the 1970s, upper gastrointestinal (UGI) endoscopy can be performed for the diagnosis and treatment of all age groups of children. We review indications, contraindications, preparation of patients for the procedure, and details of diagnostic and therapeutic UGI endoscopy used in pediatric surgery. We also discuss potential complications of endoscopy. PMID:26566483
Ono, Shoko; Ono, Masayoshi; Nakagawa, Manabu; Shimizu, Yuichi; Kato, Mototsugu; Sakamoto, Naoya
2016-04-01
Although second-look endoscopy is performed within several days after gastric endoscopic submucosal dissection (ESD), there has been no evidence supporting the usefulness of the intervention. We investigated the relationship between delayed bleeding and hemorrhage of mucosal defects after ESD on second-look endoscopy and analyzed risk factors of active bleeding on second-look endoscopy. A total of 441 consecutive ESD cases with gastric cancer or adenoma were retrospectively analyzed. Second-look endoscopy was performed in the morning after the day of ESD. Bleeding of mucosal defects on second-look endoscopy was classified according to the Forrest classification, and active bleeding was defined as Forrest Ia or Ib. Delayed bleeding was defined as hematemesis or melena after second-look endoscopy. A total of 406 second-look endoscopies were performed, and delayed bleeding occurred in 11 patients. The incidence rate of delayed bleeding after second-look endoscopy in patients with Forrest Ia or Ib was significantly higher than that in patients with Forrest IIa, IIb or III (7.69 vs. 2.02 %, p < 0.05). Complication of a histological ulcer, large size of the resected specimen and long ESD procedure time were shown to be risk factors for hemorrhage of mucosal defects after ESD on second-look endoscopy by univariate analysis. Multivariate analysis indicated that only large size of the resected specimen was a risk factor. In a specimen size of >35 mm, the odds ratio of active bleeding on second-look endoscopy was 1.9. Active bleeding of mucosal defects on second-look endoscopy is a risk factor for delayed bleeding.
Endoscopy and sedation: an inseparable binomial for the gastroenterologist.
Crespo, Javier; Terán, Álvaro
2018-04-01
The development of endoscopy and its increasing demand among the population have led to a growing need for propofol-based sedation techniques. Benefit is indisputable for both patients and endoscopists, but some aspects require considering the "who" and "how" of sedation as related to safety and health care costs. Propofol is first-choice in endoscopy for the European Society of Gastrointestinal Endoscopy because of its fast onset of action and short half-life, and many reports exist on its safety when used by gastroenterologists rather than anesthesiologists. In this issue of REED several originals support the efficiency and safety of propofol even for complex, high-risk, or protracted procedures such as endoscopic retrograde cholangiopancreatography (ERCP) and enteroscopy. Propofol may be safely and effectively administered by a team with specific skills acquired through education and using a specific procedure. However, difficulties arise in real-world clinical practice that preclude such training, which in Spain should be included in the MIR (médico interno residente) specialization program curriculum. The Comisión Nacional de Digestivo (Spanish National Commission on Digestive Diseases), sensitive to this training gap, has included in their latest version of the MIR program (under assessment) four additional competences, with number 145 (training in deep sedation) being most relevant here. In addition, the Spanish Society of Gastrointestinal Endoscopy (SEED) has invested significant efforts in sedation training, with over 50 courses on sedation for endoscopists and nurses. Continuing education and training in this field (for instance, refresher courses on advanced cardiopulmonary resuscitation) should be a goal for all endoscopy units. Because of the diversity found among hospitals, with single or multiple endoscopy rooms, efforts should be made to persuade those in charge of gastroenterology and anesthesiology departments to establish the necessary care circuits in order to guarantee patient safety by developing accurate protocols and promoting consensus among the scientific societies involved (Spanish Society for Digestive Diseases [SEPD], SEED and Spanish Society of Anaesthesiology, Resuscitation and Pain Management [SEDAR]) and their respective national commissions.
Laursen, S B; Leontiadis, G I; Stanley, A J; Hallas, J; Schaffalitzky de Muckadell, O B
2017-08-01
Observational studies have consistently shown an increased risk of upper gastrointestinal bleeding in users of selective serotonin receptor inhibitors (SSRIs), probably explained by their inhibition of platelet aggregation. Therefore, treatment with SSRIs is often temporarily withheld in patients with peptic ulcer bleeding. However, abrupt discontinuation of SSRIs is associated with development of withdrawal symptoms in one-third of patients. Further data are needed to clarify whether treatment with SSRIs is associated with poor outcomes, which would support temporary discontinuation of treatment. To identify if treatment with SSRIs is associated with increased risk of: (1) endoscopy-refractory bleeding, (2) rebleeding or (3) 30-day mortality due to peptic ulcer bleeding. A nationwide cohort study. Analyses were performed on prospectively collected data on consecutive patients admitted to hospital with peptic ulcer bleeding in Denmark in the period 2006-2014. Logistic regression analyses were used to investigate the association between treatment with SSRIs and outcome following adjustment for pre-defined confounders. Sensitivity and subgroup analyses were performed to evaluate the validity of the findings. A total of 14 343 patients were included. Following adjustment, treatment with SSRIs was not associated with increased risk of endoscopy-refractory bleeding (odds ratio [OR] [95% Confidence Interval (CI)]: 1.03 [0.79-1.33]), rebleeding (OR [95% CI]: 0.96 [0.83-1.11]) or 30-day mortality (OR [95% CI]: 1.01 [0.85-1.19]. These findings were supported by sensitivity and subgroup analyses. According to our data, treatment with SSRIs does not influence the risk of endoscopy-refractory bleeding, rebleeding or 30-day mortality in peptic ulcer bleeding. © 2017 John Wiley & Sons Ltd.
Malakar, Jadupati; Datta, Prabir Kumar; Purakayastha, Saikat Das; Dey, Sanjay; Nayak, Amit Kumar
2014-03-01
The present study deals with the development and evaluations of stomach-specific floating capsules containing salbutamol sulfate-loaded oil-entrapped alginate-based beads. Salbutamol sulfate-loaded oil-entrapped beads were prepared and capsulated within hard gelatin capsules (size 1). The effects of HPMC K4M and potato starch weight masses on drug encapsulation efficiency (DEE) of beads and cumulative drug release at 10h (R10 h) from capsules was analyzed by 3(2) factorial design. The optimization results indicate increasing of DEE in the oil-entrapped beads and decreasing R10 h from capsules with increment of HPMC K4M and potato starch weight masses. The optimized formulation showed DEE of 70.02 ± 3.16% and R10 h of 56.96 ± 2.92%. These capsules showed floatation over 6h and sustained drug release over 10h in gastric pH (1.2). In vivo X-ray imaging study of optimized floating capsules in rabbits showed stomach-specific gastroretention over a prolonged period. Copyright © 2013 Elsevier B.V. All rights reserved.
Ballistic Range Testing of the Mars Exploration Rover Entry Capsule
NASA Technical Reports Server (NTRS)
Schoenenberger, Mark; Hathaway, Wayne; Yates, Leslie; Desai, Prasun
2005-01-01
Results from a 25 shot ballistic range test of the Mars Exploration Rover (MER) aeroshell are presented. The supersonic pitch damping properties of the MER capsule were characterized between Mach = 1.5 and Mach = 3.5 and total angles-of-attack from 0 degrees to greater than 25 degrees. Three capsule center-of-gravity positions were tested across this range of conditions, 0.27, 0.30 and 0.33 body diameters aft of the nose. Parameter identification results show that the capsule is dynamically unstable at low angles-of-attack across the Mach numbers tested, with instability increasing with lower speeds. This dynamic instability was seen to increase with aft center-of-gravity movement. The MER outer mold line was very similar to the successful Mars Pathfinder capsule with only minor modifications. Pathfinder relied on Viking forced oscillation data for preflight predictions. The pitch damping data calculated from this test program are shown to more accurately reproduce the measured Path finder flight data.
"Leopard skin sign": the use of narrow-band imaging with magnification endoscopy in celiac disease.
Tchekmedyian, Asadur J; Coronel, Emmanuel; Czul, Frank
2014-01-01
Celiac Disease (CD) is an immune reaction to gluten containing foods such as rye, wheat and barley. This condition affects individuals with a genetic predisposition; it targets the small bowel and may cause symptoms including diarrhea, malabsorption, weight loss, abdominal pain and bloating. The diagnosis is made by serologic testing of celiac-specific antibodies and confirmed by histology. Certain endoscopic characteristics, such as scalloping, reduction in the number of folds, mosaic-pattern mucosa or nodular mucosa, are suggestive of CD and can be visualized under white light endoscopy. Due to its low sensitivity, endoscopy alone is not recommended to diagnose CD; however, enhanced visual identification of suspected mucosal abnormalities through the use of new technologies, such as narrow band imaging with magnification (NBI-ME), could assist in targeting biopsies and thereby increasing the sensitivity of endoscopy. This is a case series of seven patients with serologic and histologic diagnoses of CD who underwent upper endoscopies with NBI-ME imaging technology as part of their CD evaluation. By employing this imaging technology, we could identify patchy atrophy sites in a mosaic pattern, with flattened villi and alteration of the central capillaries of the duodenal mucosa. We refer to this epithelial pattern as "Leopard Skin Sign". Since epithelial lesions are easily seen using NBI-ME, we found it beneficial for identifying and targeting biopsy sites. Larger prospective studies are warranted to confirm our findings.
Yang, Hyo-Joon; Lim, Seon Hee; Lee, Changhyun; Choi, Ji Min; Yang, Jong In; Chung, Su Jin; Choi, Seung Ho; Im, Jong Pil; Kim, Sang Gyun; Kim, Joo Sung
2016-07-01
It is often difficult to differentiate gastric mucosa-associated lymphoid tissue (MALT) lymphoma from Helicobacter pylori-associated follicular gastritis, and thus, it becomes unclear how to manage these diseases. This study aimed to explore the management strategy for and the long-term outcomes of suspicious gastric MALT lymphoma detected by forceps biopsy during screening upper endoscopy. Between October 2003 and May 2013, consecutive subjects who were diagnosed with suspicious gastric MALT lymphomas by screening endoscopy in a health checkup program in Korea were retrospectively enrolled. Suspicious MALT lymphoma was defined as a Wotherspoon score of 3 or 4 upon pathological evaluation of the biopsy specimen. Of 105,164 subjects who underwent screening endoscopies, 49 patients with suspicious MALT lymphomas who underwent subsequent endoscopy were enrolled. Eight patients received a subsequent endoscopy without H. pylori eradication (subsequent endoscopy only group), and 41 patients received H. pylori eradication first followed by endoscopy (eradication first group). MALT lymphoma development was significantly lower in the eradication first group (2/41, 4.9%) than in the subsequent endoscopy only group (3/8, 37.5%, P = 0.026). Notably, among 35 patients with successful H. pylori eradication, there was only one MALT lymphoma patient (2.9%) in whom complete remission was achieved, and there was no recurrence during a median 45 months of endoscopic follow-up. H. pylori eradication with subsequent endoscopy would be a practical management option for suspicious MALT lymphoma detected in a forceps biopsy specimen obtained during screening upper endoscopy.
Does ear endoscopy provide advantages in the outpatient management of open mastoidectomy cavities?
Freire, Gustavo Subtil Magalhães; Sampaio, Andre Luiz Lopes; Lopes, Rafaela Aquino Fernandes; Nakanishi, Márcio; de Oliveira, Carlos Augusto Costa Pires
2018-01-01
To evaluate the use of ear endoscopy in the postoperative management of open mastoidectomy cavities, and to test whether ear endoscopy improves inspection and cleaning compared with ear microscopy. Prospective study. Thirty-two ears were divided into two groups: group 1, examination and cleaning of mastoid cavities under endoscopic visualization after microscopic standard ear cleaning; group 2, examination and cleaning of mastoid cavities under microscopic visualization after endoscope-assisted ear cleaning. We assessed the ability of each method to provide exposure and facilitate cleaning, comparing the benefits of microscopy and endoscopy when used sequentially and vice-versa. Endoscopy provided additional benefits for exposure in 61.1% of cases and cleaning in 66.7%. Microscopy provided no additional benefits in terms of exposure in any case, and provided added benefit for cleaning in only 21.4% of cases. For outpatient postoperative care of open mastoidectomy cavities, ear endoscopy provides greater benefit over ear microscopy than vice-versa. In over half of all cases, endoscopy was able to expose areas not visualized under the microscope. Furthermore, in two-thirds of cases, endoscopy enabled removal of material that could not be cleared under microscopy. Ear endoscopy was superior to microscopy in terms of enabling exposure and cleaning of hard-to-reach sites, due to its wider field of vision. Ear endoscopy is a feasible technique for the postoperative management of open mastoidectomy cavities. Ear endoscopy provided superior advantages in terms of exposure and aural cleaning compared with microscopy.
Endoscopy in Canada: Proceedings of the National Roundtable
Switzer, Noah; Dixon, Elijah; Tinmouth, Jill; Bradley, Nori; Vassiliou, Melina; Schwaitzberg, Steve; Gomes, Anthony; Ellsmere, James; de Gara, Chris
2015-01-01
This 2014 roundtable discussion, hosted by the Canadian Association of General Surgeons, brought together general surgeons and gastroenterologists with expertise in endoscopy from across Canada to discuss the state of endoscopy in Canada. The focus of the roundtable was the evaluation of the competence of general surgeons at endoscopy, reviewing quality assurance parameters for high-quality endoscopy, measuring and assessing surgical resident preparedness for endoscopy practice, evaluating credentialing programs for the endosuite and predicting the future of endoscopic services in Canada. The roundtable noted several important observations. There exist inadequacies in both resident training and the assessment of competency in endoscopy. From these observations, several collaborative recommendations were then stated. These included the need for a formal and standardized system of both accreditation and training endoscopists. PMID:25886520
Mihata, Teruhisa; McGarry, Michelle H; Kahn, Timothy; Goldberg, Iliya; Neo, Masashi; Lee, Thay Q
2016-01-01
Acromioplasty is increasingly being performed for both reparable and irreparable rotator cuff tears. However, acromioplasty may destroy the coracoacromial arch, including the coracoacromial ligament, consequently causing a deterioration in superior stability even after superior capsule reconstruction. The purpose of this study was to investigate the effects of acromioplasty on shoulder biomechanics after superior capsule reconstruction for irreparable supraspinatus tendon tears. The hypothesis was that acromioplasty with superior capsule reconstruction would decrease the area of subacromial impingement without increasing superior translation and subacromial contact pressure. Controlled laboratory study. Seven fresh-frozen cadaveric shoulders were evaluated using a custom shoulder testing system. Glenohumeral superior translation, the location of the humeral head relative to the glenoid, and subacromial contact pressure and area were compared among 4 conditions: (1) intact shoulder, (2) irreparable supraspinatus tendon tear, (3) superior capsule reconstruction without acromioplasty, and (4) superior capsule reconstruction with acromioplasty. Superior capsule reconstruction was performed using the fascia lata. Compared with the intact shoulder, the creation of an irreparable supraspinatus tear significantly shifted the humeral head superiorly in the balanced muscle loading condition (without superior force applied) (0° of abduction: 2.8-mm superior shift [P = .0005]; 30° of abduction: 1.9-mm superior shift [P = .003]) and increased both superior translation (0° of abduction: 239% of intact [P = .04]; 30° of abduction: 199% of intact [P = .02]) and subacromial peak contact pressure (0° of abduction: 308% of intact [P = .0002]; 30° of abduction: 252% of intact [P = .001]) by applying superior force. Superior capsule reconstruction without acromioplasty significantly decreased superior translation (0° of abduction: 86% of intact [P = .02]; 30° of abduction: 75% of intact [P = .002]) and subacromial peak contact pressure (0° of abduction: 47% of intact [P = .0002]; 30° of abduction: 83% of intact [P = .0005]; 60° of abduction: 38% of intact [P = .04]) compared with after the creation of a supraspinatus tear. Adding acromioplasty significantly decreased the subacromial contact area compared with superior capsule reconstruction without acromioplasty (0° of abduction: 26% decrease [P = .01]; 30° of abduction: 21% decrease [P = .009]; 60° of abduction: 61% decrease [P = .003]) and did not alter humeral head position, superior translation, or subacromial peak contact pressure. Superior capsule reconstruction repositioned the superiorly migrated humeral head and restored superior stability in the shoulder joint. Adding acromioplasty decreased the subacromial contact area without increasing the subacromial contact pressure. When superior capsule reconstruction is performed for irreparable rotator cuff tears, acromioplasty may help to decrease the postoperative risk of abrasion and tearing of the graft beneath the acromion. © 2015 The Author(s).
Yep-Gamarra, Víctor; Díaz-Vélez, Cristian; Araujo, Isis; Ginès, Àngels; Fernández-Esparrach, Gloria
2016-02-01
Premalignant gastric lesions have an increased risk to develop gastric cancer. To evaluate the usefulness of systematic endoscopy that includes chromoendoscopy with a double dye staining technique for the detection of dysplasia in patients with premalignant gastric lesions. This longitudinal, prospective study was performed in patients with gastric atrophy, intestinal metaplasia or dysplasia who were referred for endoscopy less than 6 months after the initial diagnosis. The second endoscopy was performed in three phases: phase 1, exhaustive and systematic review of the mucosa with photographic documentation and biopsies of suspicious areas; phase 2, chromoendoscopy with a double dye staining technique using acetic acid 1.2% and indigo carmine 0.5%; phase 3, topographic mapping and random biopsies. A total of 50 patients were included. Nine (18%) had atrophic gastritis, 38 (76%) had intestinal metaplasia, and 3 (6%) had low-grade dysplasia. Systematic endoscopy with chromoendoscopy using a double dye staining technique detected more patients with dysplasia (9 versus 3, p<.05), and a larger number of biopsies with the diagnosis of dysplasia were obtained. This occurred for visible (6 vs. 0, p<.05) and non-visible lesions (6 vs. 3, p=NS). In one patient, initial low-grade dysplasia was not detected again in the systematic endoscopy, giving a global endoscopic performance for the detection of lesions of 92%. Patients with premalignant gastric lesions have synchronous lesions with greater histological severity, which are detected when systematic endoscopy is conducted with indigo carmine dye added to acetic acid. Copyright © 2015 Elsevier España, S.L.U. and AEEH y AEG. All rights reserved.
Guideline for obtaining valid consent for gastrointestinal endoscopy procedures.
Everett, Simon M; Griffiths, Helen; Nandasoma, U; Ayres, Katie; Bell, Graham; Cohen, Mike; Thomas-Gibson, Siwan; Thomson, Mike; Naylor, Kevin M T
2016-10-01
Much has changed since the last guideline of 2008, both in endoscopy and in the practice of obtaining informed consent, and it is vital that all endoscopists who are responsible for performing invasive and increasingly risky procedures are aware of the requirements for obtaining valid consent. This guideline is restricted to GI endoscopy but we cover elective and acute or emergency procedures. Few clinical trials have been carried out in relation to informed consent but most areas are informed by guidance from the General Medical Counsel (GMC) and/or are enshrined in legislation. Following an iterative voting process a series of recommendations have been drawn up that cover the majority of situations that will be encountered by endoscopists. This is not exhaustive and where doubt exists we have described where legal advice is likely to be required. This document relates to the law and endoscopy practice in the UK-where there is variation between the four devolved countries this is pointed out and endoscopists must be aware of the law where they practice. The recommendations are divided into consent for patients with and without capacity and we provide sections on provision of information and the consent process for patients in a variety of situations. This guideline is intended for use by all practitioners who request or perform GI endoscopy, or are involved in the pathway of such patients. If followed, we hope this document will enhance the experience of patients attending for endoscopy in UK units. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
de Faria, Anderson Antônio; Dias, Carlos Alberto Freitas; Dias Moetzsohn, Luciana; de Castro Carvalho, Silas; Ferrari, Tereza Abreu; Nunes Arantes, Vitor
2017-01-01
Background and study aims Screening for esophageal and gastric varices is indicated for patients with portal hypertension or cirrhosis. Typically, conventional endoscopy is used; however, the need for sedation increases the costs and risks, especially in cirrhotic patients. Use of transnasal endoscopy with an ultrathin endoscope enables study of the upper gastrointestinal tract without the need for sedation. The objective of this study is to evaluate the feasibility of transnasal endoscopy in screening for esophageal and gastric varices in patients with chronic liver disease. Patients and methods This was a prospective study in which transnasal endoscopy was carried out in patients with cirrhosis or portal hypertension who had indications for screening of esophageal and gastric varices. The following variables were evaluated: demographical data, duration of procedure, patient tolerance and acceptance, adverse events (AEs), endoscopic findings and interobserver agreement related to portal hypertension alterations ( kappa index). Results A total of 50 patients entered the study. The most common cause of liver disease was chronic viral hepatitis (66 %). Among the cirrhotic patients, most of the patients were Child-Pugh A (74 %). In 5 patients (10 %), nasal intubation was not possible. Two patients (4 %) experienced minor epistaxis. Tolerance was excellent or good in 92 % according with a visual analogic scale. In 16 patients (32 %), esophageal varices were detected and in 2 patients (4 %) gastric varices were detected. The mean duration of the procedure was 7 minutes. Conclusions Transnasal endoscopy is feasible, effective and well tolerated for screening of esophageal and gastric varices in patients with chronic liver disease. It can be performed in outpatient clinics safely and without the use of sedation. PMID:28691048
Barham, Ahmad S; Tewes, Frederic; Healy, Anne Marie
2015-01-30
The primary objective of this paper is to compare the sorption characteristics of hydroxypropylmethylcellulose (HPMC) and hard gelatin (HG) capsules and their ability to protect capsule contents. Moisture sorption and desorption isotherms for empty HPMC and HG capsules have been investigated using dynamic vapour sorption (DVS) at 25°C. All sorption studies were analysed using the Young-Nelson model equations which distinguishes three moisture sorption types: monolayer adsorption moisture, condensation and absorption. Water vapour diffusion coefficients (D), solubility (S) and permeability (P) parameters of the capsule shells were calculated. ANOVA was performed with the Tukey comparison test to analyse the effect of %RH and capsule type on S, P, and D parameters. The moisture uptake of HG capsules were higher than HPMC capsules at all %RH conditions studied. It was found that values of D and P across HPMC capsules were greater than for HG capsules at 0-40 %RH; whereas over the same %RH range S values were higher for HG than for HPMC capsules. S values decreased gradually as the %RH was increased up to 60% RH. To probe the effect of moisture ingress, spray dried lactose was loaded into capsules. Phase evolution was characterised by scanning electron microscopy (SEM), X-ray powder diffraction (XRD), and differential scanning calorimetry (DSC). The capsules under investigation are not capable of protecting spray dried lactose from induced solid state changes as a result of moisture uptake. For somewhat less moisture sensitive formulations, HPMC would appear to be a better choice than HG in terms of protection of moisture induced deterioration. Copyright © 2014 Elsevier B.V. All rights reserved.
Magnesium Ion Acts as a Signal for Capsule Induction in Cryptococcus neoformans.
Rathore, Sudarshan S; Raman, Thiagarajan; Ramakrishnan, Jayapradha
2016-01-01
Cryptococcal meningitis caused by Cryptococcus neoformans, is a common opportunistic neural infection in immunocompromised individuals. Cryptococcus meningitis is associated with fungal burden with larger capsule size in cerebrospinal fluid (CSF). To understand the role of CSF constituents in capsule enlargement, we have evaluated the effect of artificial CSF on capsule induction in comparison with various other capsule inducing media. Two different strains of C. neoformans, an environmental and a clinical isolates were used in the present study. While comparing the various capsule inducing media for the two different strains of C. neoformans, it was observed that the capsule growth was significantly increased when grown in artificial CSF at pH 5.5, temperature 34°C for ATCC C. neoformans and 37°C for Clinical C. neoformans and with an incubation period of 72 h. In addition, artificial CSF supports biofilm formation in C. neoformans. While investigating the individual components of artificial CSF, we found that Mg(2+) ions influence the capsule growth in both environmental and clinical strains of C. neoformans. To confirm our results we studied the expression of four major CAP genes namely, CAP10, CAP59, CAP60, and CAP64 in various capsule inducing media and in different concentrations of Mg(2+) and Ca(2+). Our results on gene expression suggest that, Mg(2+) does have an effect on CAP gene expression, which are important for capsule biosynthesis and virulence. Our findings on the role of Mg(2+) ion as a signal for capsule induction will promote a way to elucidate the control mechanisms for capsule biosynthesis in C. neoformans.
Reinforcing effects of caffeine in coffee and capsules.
Griffiths, R R; Bigelow, G E; Liebson, I A
1989-09-01
In a residential research ward the reinforcing and subjective effects of caffeine were studied under double-blind conditions in volunteer subjects with histories of heavy coffee drinking. In Experiment 1, 6 subjects had 13 opportunities each day to self-administer either a caffeine (100 mg) or a placebo capsule for periods of 14 to 61 days. All subjects developed a clear preference for caffeine, with intake of caffeine becoming relatively stable after preference had been attained. Preference for caffeine was demonstrated whether or not preference testing was preceded by a period of 10 to 37 days of caffeine abstinence, suggesting that a recent history of heavy caffeine intake (tolerance/dependence) was not a necessary condition for caffeine to function as a reinforcer. In Experiment 2, 6 subjects had 10 opportunities each day to self-administer a cup of coffee or (on different days) a capsule, dependent upon completing a work requirement that progressively increased and then decreased over days. Each day, one of four conditions was studied: caffeinated coffee (100 mg/cup), decaffeinated coffee, caffeine capsules (100 mg/capsule), or placebo capsules. Caffeinated coffee maintained the most self-administration, significantly higher than decaffeinated coffee and placebo capsules but not different from caffeine capsules. Both decaffeinated coffee and caffeine capsules were significantly higher than placebo capsules but not different from each other. In both experiments, subject ratings of "linking" of coffee or capsules covaried with the self-administration measures. These experiments provide the clearest demonstrations to date of the reinforcing effects of caffeine in capsules and in coffee.
Reinforcing effects of caffeine in coffee and capsules.
Griffiths, R R; Bigelow, G E; Liebson, I A
1989-01-01
In a residential research ward the reinforcing and subjective effects of caffeine were studied under double-blind conditions in volunteer subjects with histories of heavy coffee drinking. In Experiment 1, 6 subjects had 13 opportunities each day to self-administer either a caffeine (100 mg) or a placebo capsule for periods of 14 to 61 days. All subjects developed a clear preference for caffeine, with intake of caffeine becoming relatively stable after preference had been attained. Preference for caffeine was demonstrated whether or not preference testing was preceded by a period of 10 to 37 days of caffeine abstinence, suggesting that a recent history of heavy caffeine intake (tolerance/dependence) was not a necessary condition for caffeine to function as a reinforcer. In Experiment 2, 6 subjects had 10 opportunities each day to self-administer a cup of coffee or (on different days) a capsule, dependent upon completing a work requirement that progressively increased and then decreased over days. Each day, one of four conditions was studied: caffeinated coffee (100 mg/cup), decaffeinated coffee, caffeine capsules (100 mg/capsule), or placebo capsules. Caffeinated coffee maintained the most self-administration, significantly higher than decaffeinated coffee and placebo capsules but not different from caffeine capsules. Both decaffeinated coffee and caffeine capsules were significantly higher than placebo capsules but not different from each other. In both experiments, subject ratings of "linking" of coffee or capsules covaried with the self-administration measures. These experiments provide the clearest demonstrations to date of the reinforcing effects of caffeine in capsules and in coffee. PMID:2794839
Szweda, Magdalena; Szarek, Józef; Dublan, Krystyna; Męcik-Kronenberg, Tomasz; Kiełbowicz, Zdzisław; Bigoszewski, Marcin
2014-01-01
Non-steroidal anti-inflammatory drugs (NSAIDs) may cause gastrointestinal damage in dogs. To determine the extent to which lansoprazole, liquorice extract, and a herbal solution exhibit protective effects on colonic mucosa when administered to dogs concurrently with the NSAIDs carprofen or robenacoxib. Thirty-five healthy beagle dogs (15 male and 20 female) aged 13-14 weeks and weighing 4.3-5.5 kg at the beginning of the experiment were included. Endoscopy and biopsy of the caudal gastrointestinal tract were performed pretreatment and on the last day of a 21-day treatment period with (1) oral carprofen; (2) carprofen and the proton-pump inhibitor lansoprazole; (3) carprofen, liquorice extract, and a herbal solution that contained extracts of thyme, icelandic lichen, hyssop, and saponariae root; (4) robenacoxib; (5) robenacoxib and lansoprazole; (6) robenacoxib, liquorice extract, and herbal solution; or (7) an empty gelatin capsule. Statistical analyses were performed with the Kruskal-Wallis, Cochran's Q, and chi-squared test with p < 0.05 considered significant. Both carprofen and robenacoxib tested damaged the colonic mucosa with most severe microscopic lesions following administration of robenacoxib with lansoprazole. The risk of histopathological lesions in the colon increased most rapidly in robenacoxib with lansoprazole (absolute risk increase -0.85) similar to robenacoxib only (-0.75), whereas the best result was recorded following the plant remedies together with carprofen (-0.15) and the plant remedies together with robenacoxib (-0.2). Concurrent administration of liquorice extract and an herbal solution with robenacoxib was associated with decreased severity of the NSAID-induced mucosal lesions.
Visualization of Capsule Reentry Vehicle Heat Shield Ablation Using Naphthalene PLIF
NASA Technical Reports Server (NTRS)
Combs, Christopher S.; Clemens, Noel T.; Danehy, Paul M.
2014-01-01
The Orion Multi-Purpose Crew Vehicle (MPCV) will use an ablative heat shield and improved understanding of the ablation process would be beneficial for design purposes. Given that ablation is a multi-physics process involving heat and mass transfer, codes aiming to predict heat shield ablation are in need of experimental data pertaining to the turbulent transport of ablation products for validation. At The University of Texas at Austin, a technique is being developed that uses planar laser-induced fluorescence (PLIF) of a low-temperature sublimating ablator (naphthalene) to visualize the transport of ablation products in a supersonic flow. Since ablation at reentry temperatures can be difficult to recreate in a laboratory setting it is desirable to create a limited physics problem and simulate the ablation process at relatively low temperature conditions using naphthalene. A scaled Orion MPCV model with a solid naphthalene heat shield has been tested in a Mach 5 wind tunnel at various angles of attack in the current work. PLIF imaging reveals the distribution of the ablation products as they are transported into the heat-shield boundary layer and over the capsule shoulders into the separated shear layer and backshell recirculation region. Visualizations of the capsule shear layer using both naphthalene PLIF and Schlieren imaging compared favorably. High concentrations of naphthalene in the capsule separated flow region, intermittent turbulent structures on the heat shield surface, and interesting details of the capsule shear layer structure were observed using the naphthalene PLIF technique. The capsule shear layer was also shown to generally appear to be more turbulent at lower angles of attack. Furthermore, the PLIF signal increased steadily over the course of a run indicating that during a wind tunnel run the model heated up and the rate of naphthalene ablation increased. The shear layer showed increasing signs of turbulence over the course of a wind tunnel run as well, likely because of the combination of increased surface roughness and surface blowing rate. PLIF imaging also detected regions with a relatively low concentration of naphthalene in the capsule backshell recirculation region that are most likely the result of cross-flow-induced vortices on the capsule afterbody.
Alginate/sodium caseinate aqueous-core capsules: a pH-responsive matrix.
Ben Messaoud, Ghazi; Sánchez-González, Laura; Jacquot, Adrien; Probst, Laurent; Desobry, Stéphane
2015-02-15
Alginate capsules have several applications. Their functionality depends considerably on their permeability, chemical and mechanical stability. Consequently, the creation of composite system by addition of further components is expected to control mechanical and release properties of alginate capsules. Alginate and alginate-sodium caseinate composite liquid-core capsules were prepared by a simple extrusion. The influence of the preparation pH and sodium caseinate concentration on capsules physico-chemical properties was investigated. Results showed that sodium caseinate influenced significantly capsules properties. As regards to the membrane mechanical stability, composite capsules prepared at pH below the isoelectric point of sodium caseinate exhibited the highest surface Young's modulus, increasing with protein content, explained by potential electrostatic interactions between sodium caseinate amino-groups and alginate carboxylic group. The kinetic of cochineal red A release changed significantly for composite capsules and showed a pH-responsive release. Sodium caseinate-dye mixture studied by absorbance and fluorescence spectroscopy confirmed complex formation at pH 2 by electrostatic interactions between sodium caseinate tryptophan residues and cochineal red sulfonate-groups. Consequently, the release mechanism was explained by membrane adsorption process. This global approach is useful to control release mechanism from macro and micro-capsules by incorporating guest molecules which can interact with the entrapped molecule under specific conditions. Copyright © 2014 Elsevier Inc. All rights reserved.
Laing, Karen; Baumgartner, Katherine
2005-01-01
Many endoscopy units are looking for ways to improve their efficiency without increasing the number of staff, purchasing additional equipment, or making the patients feel as if they have been rushed through the care process. To accomplish this, a few hospitals have looked to other industries for help. Recently, "lean" methods and tools from the manufacturing industry, have been applied successfully in health care systems, and have proven to be an effective way to eliminate waste and redundancy in workplace processes. The "lean" method and tools in service organizations focuses on providing the most efficient and effective flow of service and products. This article will describe the journey of one endoscopy department within a community hospital to illustrate application of "lean" methods and tools and results.
Kronschläger, Martin; Stimpfl, Thomas; Ruiß, Manuel; Hirnschall, Nino; Leisser, Christoph; Findl, Oliver
2018-04-01
To determine the pharmacokinetics of perorally administered caffeine, a widely consumed and potent dietary antioxidant, in the anterior lens capsule and lens epithelial cells, a crucial cell monolayer for cataract development. Bilateral cataract patients were scheduled for cataract surgery with a caffeine abstinence of 1 week before surgery of each eye. At the day of surgery of the second eye patients were administered no drink (0-mg group) or coffee with 60-, 120-, or 180-mg caffeine. After capsulorhexis the lens capsule including lens epithelial cells was transferred to a test tube for analysis of caffeine concentration by gas chromatography-mass spectrometry (GC-MS/MS). Coffee consumption significantly (P < 0.05) increased caffeine levels of the lens capsule/epithelium in the 60-, 120-, and 180-mg group. Caffeine concentrations (caffeine ng/lens capsule/epithelium) measured as difference between 1st and 2nd eye were -0.52 ± 1.16 (0-mg group, n = 7), 1.88 ± 2.02 (60-mg group, n = 8), 2.09 ± 0.67 (120-mg group, n = 9), and 3.68 ± 1.86 (180-mg group, n = 9). The increase constant of caffeine in a linear regression model was estimated as a 95% CI 0.02 ± 0.0046 (degrees of freedom; 25; r = 0.85). Peroral intake of coffee significantly increased caffeine concentrations in the lens capsule and lens epithelial cells in a dose-dependent manner. This information is important for further investigations on preventing cataract.
Magnesium Ion Acts as a Signal for Capsule Induction in Cryptococcus neoformans
Rathore, Sudarshan S.; Raman, Thiagarajan; Ramakrishnan, Jayapradha
2016-01-01
Cryptococcal meningitis caused by Cryptococcus neoformans, is a common opportunistic neural infection in immunocompromised individuals. Cryptococcus meningitis is associated with fungal burden with larger capsule size in cerebrospinal fluid (CSF). To understand the role of CSF constituents in capsule enlargement, we have evaluated the effect of artificial CSF on capsule induction in comparison with various other capsule inducing media. Two different strains of C. neoformans, an environmental and a clinical isolates were used in the present study. While comparing the various capsule inducing media for the two different strains of C. neoformans, it was observed that the capsule growth was significantly increased when grown in artificial CSF at pH 5.5, temperature 34°C for ATCC C. neoformans and 37°C for Clinical C. neoformans and with an incubation period of 72 h. In addition, artificial CSF supports biofilm formation in C. neoformans. While investigating the individual components of artificial CSF, we found that Mg2+ ions influence the capsule growth in both environmental and clinical strains of C. neoformans. To confirm our results we studied the expression of four major CAP genes namely, CAP10, CAP59, CAP60, and CAP64 in various capsule inducing media and in different concentrations of Mg2+ and Ca2+. Our results on gene expression suggest that, Mg2+ does have an effect on CAP gene expression, which are important for capsule biosynthesis and virulence. Our findings on the role of Mg2+ ion as a signal for capsule induction will promote a way to elucidate the control mechanisms for capsule biosynthesis in C. neoformans. PMID:27014245
Virtual endoscopic imaging of the spine.
Kotani, Toshiaki; Nagaya, Shigeyuki; Sonoda, Masaru; Akazawa, Tsutomu; Lumawig, Jose Miguel T; Nemoto, Tetsuharu; Koshi, Takana; Kamiya, Koshiro; Hirosawa, Naoya; Minami, Shohei
2012-05-20
Prospective trial of virtual endoscopy in spinal surgery. To investigate the utility of virtual endoscopy of the spine in conjunction with spinal surgery. Several studies have described clinical applications of virtual endoscopy to visualize the inside of the bronchi, paranasal sinus, stomach, small intestine, pancreatic duct, and bile duct, but, to date, no study has described the use of virtual endoscopy in the spine. Virtual endoscopy is a realistic 3-dimensional intraluminal simulation of tubular structures that is generated by postprocessing of computed tomographic data sets. Five patients with spinal disease were selected: 2 patients with degenerative disease, 2 patients with spinal deformity, and 1 patient with spinal injury. Virtual endoscopy software allows an observer to explore the spinal canal with a mouse, using multislice computed tomographic data. Our study found that virtual endoscopy of the spine has advantages compared with standard imaging methods because surgeons can noninvasively explore the spinal canal in all directions. Virtual endoscopy of the spine may be useful to surgeons for diagnosis, preoperative planning, and postoperative assessment by obviating the need to mentally construct a 3-dimensional picture of the spinal canal from 2-dimensional computed tomographic scans.
Fujimori, Shunji; Hanada, Ryuzo; Hayashida, Mari; Sakurai, Toshiyuki; Ikushima, Ippei; Sakamoto, Choitsu
2016-03-01
The aim of this study was to compare celecoxib with loxoprofen for protection of small intestine. RCT studies report that COX-2 selective inhibitor celecoxib induces fewer small intestinal injuries than nonselective nonsteroidal anti-inflammatory drugs (NSAIDs). Loxoprofen is a prodrug nonselective NSAID developed to protect upper gastrointestinal tract. A total of 150 healthy volunteers (40 to 70 y) were enrolled. After medical checkup including laboratory data, subjects were randomly assigned to celecoxib (200 mg daily) or loxoprofen (180 mg daily) plus lansoprazole (15 mg daily). All drugs were prepared using inactive capsules. After randomization, all subjects were first examined by baseline capsule endoscopy (CE). After 14 days, subjects underwent posttreatment CE. We compared baseline and posttreatment CE findings of the 2 groups. All CE data were evaluated blindly by 3 reviewers. Pretreatment and posttreatment laboratory variables were also compared. A total of 74 subjects (49±6 y, F/M: 36/38) were enrolled in celecoxib group and 76 subjects (49±7 y, F/M: 39/37)in loxoprofen group. Five in celecoxib group and 4 in loxoprofen group were excluded from CE analysis mainly due to incomplete CE. The percentage of subjects with at least 1 posttreatment mucosal break was lower in celecoxib group (10%) than in loxoprofen group (49%) (P<0.0001). A total of 0.3±1.0 posttreatment small intestinal mucosal breaks were detected in the celecoxib group, and 6.8±21.5 in the loxoprofen group (P<0.0001). Posttreatment hemoglobin concentration in loxoprofen group (5.1% reduction) was lower compared with celecoxib group (2.1% reduction) (P=0.006). In terms of protection of small intestine from NSAIDs toxicity, celecoxib monotherapy was superior to loxoprofen+lansoprazole combination therapy (UMIN: 000007936).
Duggan, A E; Elliott, C A; Miller, P; Hawkey, C J; Logan, R F A
2009-01-01
Early endoscopy, Helicobacter pylori eradication and empirical acid suppression are commonly used dyspepsia management strategies in primary care but have not been directly compared in a single trial. To compare endoscopy, H. pylori test and refer, H. pylori test and treat and empirical acid suppression for dyspepsia in primary care. Patients presenting to their general practitioner with dyspepsia were randomized to endoscopy, H. pylori'test and treat', H. pylori test and endoscope positives, or empirical therapy with symptoms, patient satisfaction, healthcare costs and cost effectiveness at 12 months being the outcomes. At 2 months, the proportion of patients reporting no or minimal dyspeptic symptoms ranged from 74% for those having early endoscopy to 55% for those on empirical therapy (P = 0.009), but at 1 year, there was little difference among the four strategies. Early endoscopy was associated with fewer subsequent consultations for dyspepsia (P = 0.003). 'Test and treat' resulted in fewer endoscopies overall and was most cost-effective over a range of cost assumptions. Empirical therapy resulted in the lowest initial costs, but the highest rate of subsequent endoscopy. Gastro-oesophageal cancers were found in four patients randomized to the H. pylori testing strategies. While early endoscopy offered some advantages 'Test and treat' was the most cost-effective strategy. In older patients, early endoscopy may be an appropriate strategy in view of the greater risk of malignant disease. © 2008 The Authors. Journal compilation © 2008 Blackwell Publishing Ltd.
Hyperspectral Imaging Using Flexible Endoscopy for Laryngeal Cancer Detection
Regeling, Bianca; Thies, Boris; Gerstner, Andreas O. H.; Westermann, Stephan; Müller, Nina A.; Bendix, Jörg; Laffers, Wiebke
2016-01-01
Hyperspectral imaging (HSI) is increasingly gaining acceptance in the medical field. Up until now, HSI has been used in conjunction with rigid endoscopy to detect cancer in vivo. The logical next step is to pair HSI with flexible endoscopy, since it improves access to hard-to-reach areas. While the flexible endoscope’s fiber optic cables provide the advantage of flexibility, they also introduce an interfering honeycomb-like pattern onto images. Due to the substantial impact this pattern has on locating cancerous tissue, it must be removed before the HS data can be further processed. Thereby, the loss of information is to minimize avoiding the suppression of small-area variations of pixel values. We have developed a system that uses flexible endoscopy to record HS cubes of the larynx and designed a special filtering technique to remove the honeycomb-like pattern with minimal loss of information. We have confirmed its feasibility by comparing it to conventional filtering techniques using an objective metric and by applying unsupervised and supervised classifications to raw and pre-processed HS cubes. Compared to conventional techniques, our method successfully removes the honeycomb-like pattern and considerably improves classification performance, while preserving image details. PMID:27529255
Hyperspectral Imaging Using Flexible Endoscopy for Laryngeal Cancer Detection.
Regeling, Bianca; Thies, Boris; Gerstner, Andreas O H; Westermann, Stephan; Müller, Nina A; Bendix, Jörg; Laffers, Wiebke
2016-08-13
Hyperspectral imaging (HSI) is increasingly gaining acceptance in the medical field. Up until now, HSI has been used in conjunction with rigid endoscopy to detect cancer in vivo. The logical next step is to pair HSI with flexible endoscopy, since it improves access to hard-to-reach areas. While the flexible endoscope's fiber optic cables provide the advantage of flexibility, they also introduce an interfering honeycomb-like pattern onto images. Due to the substantial impact this pattern has on locating cancerous tissue, it must be removed before the HS data can be further processed. Thereby, the loss of information is to minimize avoiding the suppression of small-area variations of pixel values. We have developed a system that uses flexible endoscopy to record HS cubes of the larynx and designed a special filtering technique to remove the honeycomb-like pattern with minimal loss of information. We have confirmed its feasibility by comparing it to conventional filtering techniques using an objective metric and by applying unsupervised and supervised classifications to raw and pre-processed HS cubes. Compared to conventional techniques, our method successfully removes the honeycomb-like pattern and considerably improves classification performance, while preserving image details.
Huerta, Elisa; Serapian, Stefano Artin; Santos, Eva; Cequier, Enrique; Bo, Carles; de Mendoza, Javier
2016-09-12
Fullerenes C60 , C70 , and C84 may be readily encaged within a hydrogen-bonded dimeric capsule, based on two concave cyclotriveratrylene (CTV) scaffolds, each containing three self-complementary 2-ureido-4-[1H]-pyrimidinone (UPy) subunits. NMR spectroscopy and circular dichroism studies, complemented by dispersion-corrected DFT calculations, are reported with the aim of characterizing such capsule-fullerene complexes both structurally and energetically. Six fullerenes are considered: in agreement with experiments, calculations find that encapsulation is most favorable for C84 (on a par with C90 ), and follows the trend C60
Ileal polypoid lymphangiectasia bleeding diagnosed and treated by double balloon enteroscopy.
Park, Min Seon; Lee, Beom Jae; Gu, Dae Hoe; Pyo, Jeung-Hui; Kim, Kyeong Jin; Lee, Yun Ho; Joo, Moon Kyung; Park, Jong-Jae; Kim, Jae Seon; Bak, Young-Tae
2013-12-07
Intestinal lymphangiectasia is a rare disease characterized by focal or diffuse dilated enteric lymphatics with impaired lymph drainage. It causes protein-losing enteropathy and may lead to gastrointestinal bleeding. Commonly, lymphangiectasia presents as whitish spots or specks. To our knowledge, small bowel bleeding resulting from polypoid intestinal lymphangiectasia has not been reported. Here, we report a rare case of active bleeding from the small bowel caused by polypoid lymphangiectasia with a review of the relevant literature. An 80-year-old woman was hospitalized for melena. Esophagogastroduodenoscopy could not identify the source of bleeding. Subsequent colonoscopy showed fresh bloody material gushing from the small bowel. An abdominal-pelvic contrast-enhanced computed tomography scan did not reveal any abnormal findings. Video capsule endoscopy showed evidence of active and recent bleeding in the ileum. To localize the bleeding site, we performed double balloon enteroscopy by the anal approach. A small, bleeding, polypoid lesion was found in the distal ileum and was successfully removed using endoscopic snare electrocautery. © 2013 Baishideng Publishing Group Co., Limited. All rights reserved.
Okabayashi, Shinji; Sujino, Tomohisa; Ozaki, Ryo; Umeda, Satoko; Toyonaga, Takahiko; Saito, Eiko; Nakano, Masaru; Tablante, Maria Carla; Morinaga, Shojiroh; Hibi, Toshifumi
2017-01-01
Extracolonic involvement of the gastrointestinal tract is extremely uncommon in ulcerative colitis (UC) and rarely found in the upper gastrointestinal tract or in postoperative cases since it typically responds to steroids. Here we report a case of UC complicated by extensive ileal inflammation that was refractory to steroids. A 20-year-old man was diagnosed with UC of typical pancolitis without ileal involvement and started treatment with pH-dependent mesalazine and oral prednisolone. Although his symptoms transiently resolved, the condition flared when the steroid dose was tapered down. Computed tomography revealed marked thickening of the ileal wall, and capsule endoscopy and balloon-assisted enteroscopy found diffuse mucosal inflammation with ulcers in the ileum. On the contrary, the inflammation in the colon and rectum was improving. Since the response to the second steroid course was inadequate, treatment with adalimumab and 6-mercaptopurine was initiated and finally achieved clinical and endoscopic remission. The investigation of small intestinal lesions is necessary in patients with UC whose clinical deterioration cannot be explained by colonic lesions. PMID:29142523
Ikeda-Dantsuji, Yurika; Ohno, Hideaki; Tanabe, Koichi; Umeyama, Takashi; Ueno, Keigo; Nagi, Minoru; Yamagoe, Satoshi; Kinjo, Yuki; Miyazaki, Yoshitsugu
2015-12-01
Among invasive fungal infections, cryptococcosis caused by inhalation of Cryptococcus neoformans or Cryptococcus gattii is particularly dangerous because it can disseminate to the central nervous system and cause life-threatening meningitis or meningoencephalitis. Previous reports described significant differences in the histopathological features of C. neoformans and C. gattii infection, such as greater pathogen proliferation and a limited macrophage response in mouse lung infected by C. gattii. To elucidate the difference in pathogenicity of these two Cryptococcus species, we investigated the interaction of C. neoformans and C. gattii with murine macrophages, the first line of host defense, by confocal laser microscopy. Only thin-capsulated, and not thick-capsulated C. neoformans and C. gattii were phagocytosed by macrophages. Preactivation with interferon-γ increased the phagocytic rate of thin-capsulated C. neoformans up to two-fold, but did not promote phagocytosis of thin-capsulated C. gattii. Lipopolysaccharide preactivation or Aspergillus fumigatus conidia co-incubation had no effect on internalization of thin-capsulated C. neoformans or C. gattii by macrophages. Phagocytosis of live thin-capsulated C. neoformans, but not that of live thin-capsulated C. gattii, induced interleukin-12 release from macrophages. However, phagocytosis of heat-killed or paraformaldehyde-fixed thin-capsulated C. neoformans did not increase IL-12 release, showing that the internalization of live yeast is important for initiating the immune response during C. neoformans-macrophage interactions. Our data suggest that macrophage response to C. gattii is limited compared with that to C. neoformans and that these results may partially explain the limited immune response and the greater pathogenicity of C. gattii. Copyright © 2015 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Wrobeln, Anna; Schlüter, Klaus D; Linders, Jürgen; Zähres, Manfred; Mayer, Christian; Kirsch, Michael; Ferenz, Katja B
2017-06-01
The aim of this study was to prove whether albumin-derived perfluorocarbon-based nanoparticles (capsules) can operate as a novel artificial oxygen carrier in a rat Langendorff-heart perfusion model. Hearts perfused with capsules showed increased left ventricular pressure and rate pressure product compared to hearts perfused with pure Krebs-Henseleit (KH)-buffer. The capsules prevented the myocardium from functional fail when in their absence a noxious ischemia was observed. Capsules did not change rheological properties of KH-buffer and could repeatedly reload with oxygen. This albumin-derived perfluorocarbon-based artificial oxygen carrier preserved the function of rat hearts due to the transport of oxygen in a satisfactory manner. Because of these positive results, the functionality of the applied capsules should be verified in living animals.
Guidelines for Safety in the Gastrointestinal Endoscopy Unit
Calderwood, Audrey H.; Chapman, Frank J.; Cohen, Jonathan; Cohen, Lawrence B.; Collins, James; Day, Lukejohn W.; Early, Dayna S.
2014-01-01
EXECUTIVE SUMMARY Historically, safety in the gastrointestinal (GI) endoscopy unit has focused on infection control, particularly around the reprocessing of endoscopes. Two highly publicized outbreaks where the transmission of infectious agents were related to GI endoscopy have highlighted the need to address potential gaps along the endoscopy care continuum that could impact patient safety. PMID:24485393
Development of three-layered rumen escapable capsules for cattle
SEYAMA, Tomohiro; HIRAYASU, Hirofumi; YAMAWAKI, Kenji; ADACHI, Takuhiko; SUGIMOTO, Takayuki; KASAI, Koji
2016-01-01
A new rumen escapable tool is presented for cattle in prospect of developing medical treatment or supplementing trace elements for disease prevention. This tool consists of a three-layered capsule that dissolves in the lower digestive tract, but not in the rumen. The capsule was manufactured by capsule-forming techniques through the use of liquid surface tension. This method does not involve high-temperature treatment, so the capsule can contain not only lipophilic substances but also hydrophilic or heat-sensitive substances. Furthermore, the capsule has a specific gravity of 1.3 and diameter of 6.0 mm, which were previously shown to be appropriate to avoid rumination. The objective of this study was to confirm the effectiveness of the capsule pertinent to rumen escaping. In order to validate rumen escape, capsules containing 30 g of water-soluble vitamin (thiamine hydrochloride) per head were administered to four lactating cows assigned in a crossover trial. In the group administered encapsulated thiamine hydrochloride, blood thiamine levels increased from 12.4 ± 1.03 ng/ml before administration to 54.8 ± 2.21 ng/ml at 6 hr following administration, whereas the level remained at 13.3 ± 2.05 ng/ml in the control group administered via aqueous solution. This indicates that the three-layered capsules passed through the rumen and dissolved in the lower digestive tract, thus functioning as a rumen escapable tool. PMID:27546371
Elvas, Luís; Areia, Miguel; Brito, Daniel; Alves, Susana; Saraiva, Sandra; Cadime, Ana T
2017-02-01
Background and study aim Upper endoscopy is the most common method for the diagnosis of upper gastrointestinal tract diseases. The aim of this study was to determine whether premedication with simethicone or N -acetylcysteine improves mucosal visualization during upper endoscopy. Patients and methods This was a randomized, double-blind, placebo-controlled study of 297 patients scheduled for upper endoscopy who were premedicated 15 - 30 minutes before the procedure with: 100 mL of water (placebo, group A); water plus 100 mg simethicone (group B); water plus 100 mg simethicone plus 600 mg N -acetylcysteine (group C). The primary outcome measure was the quality of mucosal visualization (score: excellent, adequate or inadequate). Results The addition of simethicone (group B) or simethicone plus N -acetylcysteine to the water (group C) improved the visualization scores of endoscopies compared with water alone (group A). In particular, groups B and C produced a significantly higher percentage of endoscopies with excellent visualization for the esophagus (91.1 % and 86.7 %, respectively, vs. 71.4 % in group A; P < 0.001) and stomach (76.2 % and 74.5 % vs. 38.8 % in group A; P < 0.001). For the duodenum, the use of simethicone also showed an increase in the endoscopies with excellent visualization compared with water alone (85.1 % vs. 73.5 %; P = 0.042). There were no significant differences in scores between groups B and C or between gastric scores in patients with previous subtotal gastrectomy (B and C vs. A): 60.0 % and 42.1 % vs. 28.6 % ( P = 0.14). The rate of reported lesions was higher in group B but without statistical significance. Conclusions Premedication with simethicone resulted in better mucosal visibility. Such premedication might improve diagnostic yield, and should be considered for standard practice. Trial registered at ClinicalTrials.gov (NCT02357303). © Georg Thieme Verlag KG Stuttgart · New York.
Subsite-specific colorectal cancer risk in the colorectal endoscopy era.
Stock, Christian; Pulte, Dianne; Haug, Ulrike; Brenner, Hermann
2012-03-01
Colorectal endoscopy (sigmoidoscopy and colonoscopy) is thought to reduce colorectal cancer (CRC) risk. Since the 1980s, its use has increased in the United States, which may be a reason for decreasing CRC incidence rates. To investigate the plausibility of a contribution of colorectal endoscopy use to the decrease in CRC risk. Descriptive analysis of temporal trends. U.S. population from 1978 to 2007. Using incidence data from the Surveillance, Epidemiology and End Results Program, we assessed the subsite-specific cumulative risk of CRC developing until age 79 years. The cumulative risk of proximal CRC remained relatively stable over the observation period, varying between 2.09% (95% CI, 2.06%-2.11%) and 2.66% (95% CI,2.62%-2.69%) for men and between 1.90% (95% CI, 1.88%-1.93%) and 2.24% (95% CI, 2.21%-2.27%) for women. By contrast, the cumulative risk of distal CRC decreased from 4.68% (95% CI, 4.64%-4.73%) to 3.03% (95% CI, 3.00%-3.06%) for men and from 3.15% (95% CI, 3.11%-3.18%) to 1.93% (95% CI, 1.91%-1.95%) for women, which was largely attributable to the reduced cumulative risk of cancer in the sigmoid colon. The observed pattern was restricted to the population aged 50 to 79 years, whereas the magnitude of the decrease was greater for older age groups and similar across stages. The study is based on aggregated registry data only; therefore, no inferences about causal effects can be drawn. The results show a major reduction of CRC risk, particularly in the sigmoid colon. Increased use of colorectal endoscopy in the population aged 50 years and older along with environmental factors may have contributed to the decreasing risk. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Person-centered endoscopy safety checklist: Development, implementation, and evaluation
Dubois, Hanna; Schmidt, Peter T; Creutzfeldt, Johan; Bergenmar, Mia
2017-01-01
AIM To describe the development and implementation of a person-centered endoscopy safety checklist and to evaluate the effects of a “checklist intervention”. METHODS The checklist, based on previously published safety checklists, was developed and locally adapted, taking patient safety aspects into consideration and using a person-centered approach. This novel checklist was introduced to the staff of an endoscopy unit at a Stockholm University Hospital during half-day seminars and team training sessions. Structured observations of the endoscopy team’s performance were conducted before and after the introduction of the checklist. In addition, questionnaires focusing on patient participation, collaboration climate, and patient safety issues were collected from patients and staff. RESULTS A person-centered safety checklist was developed and introduced by a multi-professional group in the endoscopy unit. A statistically significant increase in accurate patient identity verification by the physicians was noted (from 0% at baseline to 87% after 10 mo, P < 0.001), and remained high among nurses (93% at baseline vs 96% after 10 mo, P = nonsignificant). Observations indicated that the professional staff made frequent attempts to use the checklist, but compliance was suboptimal: All items in the observed nurse-led “summaries” were included in 56% of these interactions, and physicians participated by directly facing the patient in 50% of the interactions. On the questionnaires administered to the staff, items regarding collaboration and the importance of patient participation were rated more highly after the introduction of the checklist, but this did not result in statistical significance (P = 0.07/P = 0.08). The patients rated almost all items as very high both before and after the introduction of the checklist; hence, no statistical difference was noted. CONCLUSION The intervention led to increased patient identity verification by physicians - a patient safety improvement. Clear evidence of enhanced person-centeredness or team work was not found. PMID:29358869
Evaluating quality in endoscopy.
Pohl, Heiko
2017-06-01
Despite an increasing number of publications and suggested quality measures, evaluating quality in endoscopy remains a challenge. Most quality measures are process measures and lack evidence for an association with clinically important outcomes. Furthermore, most measure focus on procedural aspects. Patients' expectations, cultural values, and work setting also affect quality, but are less often considered. The aim of this article is to broaden the view on quality assessment. Here, quality is viewed from four perspectives: an individual patient perspective, which considers expectations and personal values; a cultural perspective, which encompasses cultural values and norms; an individual care perspective, which includes how an individual patient is being treated; and a societal perspective, which sets the stage for provided care. The article concludes with a proposal to consider bundled composite measures as a path to a simple yet comprehensive approach to assessing and measuring quality in endoscopy. © Georg Thieme Verlag KG Stuttgart · New York.
Endoscopic Therapy in Crohn's Disease: Principle, Preparation, and Technique.
Chen, Min; Shen, Bo
2015-09-01
Stricture and fistula are common complications of Crohn's disease. Endoscopic balloon dilation and needle-knife stricturotomy has become a valid treatment option for Crohn's disease-associated strictures. Endoscopic therapy is also increasingly used in Crohn's disease-associated fistula. Preprocedural preparations, including routine laboratory testing, imaging examination, anticoagulant management, bowel cleansing and proper sedation, are essential to ensure a successful and safe endoscopic therapy. Adverse events, such as perforation and excessive bleeding, may occur during endoscopic intervention. The endoscopist should be well trained, always be cautious, anticipate for possible procedure-associated complications, be prepared for damage control during endoscopy, and have surgical backup ready. In this review, we discuss the principle, preparation, techniques of endoscopic therapy, as well as the prevention and management of endoscopic procedure-associated complications. We propose that inflammatory bowel disease endoscopy may be a part of training for "super" gastroenterology fellows, i.e., those seeking a career in advanced endoscopy or in inflammatory bowel disease.
Parot, Vicente; Lim, Daryl; González, Germán; Traverso, Giovanni; Nishioka, Norman S; Vakoc, Benjamin J; Durr, Nicholas J
2013-07-01
While color video endoscopy has enabled wide-field examination of the gastrointestinal tract, it often misses or incorrectly classifies lesions. Many of these missed lesions exhibit characteristic three-dimensional surface topographies. An endoscopic system that adds topographical measurements to conventional color imagery could therefore increase lesion detection and improve classification accuracy. We introduce photometric stereo endoscopy (PSE), a technique which allows high spatial frequency components of surface topography to be acquired simultaneously with conventional two-dimensional color imagery. We implement this technique in an endoscopic form factor and demonstrate that it can acquire the topography of small features with complex geometries and heterogeneous optical properties. PSE imaging of ex vivo human gastrointestinal tissue shows that surface topography measurements enable differentiation of abnormal shapes from surrounding normal tissue. Together, these results confirm that the topographical measurements can be obtained with relatively simple hardware in an endoscopic form factor, and suggest the potential of PSE to improve lesion detection and classification in gastrointestinal imaging.
Cryptococcus neoformans responds to mannitol by increasing capsule size in vitro and in vivo
Guimarães, Allan Jefferson; Frases, Susana; Cordero, Radamés J. B.; Nimrichter, Leonardo; Casadevall, Arturo; Nosanchuk, Joshua D.
2010-01-01
The polysaccharide capsule of the fungus Cryptococcus neoformans is its main virulence factor. In this study, we determined the effects of mannitol and glucose on the capsule and exopolysaccharide production. Growth in mannitol significantly increased capsular volume compared to cultivation in glucose. However, cells grown in glucose concentrations higher than 62.5mM produced more exopolysaccharide than cells grown in mannitol. The fiber lengths and glycosyl composition of capsular polysaccharide from yeast grown in mannitol was structurally different from that of yeast grown in glucose. Furthermore, mannitol treatment of mice infected intratracheally with C. neoformans resulted in fungal cells with significantly larger capsules and the mice had reduced fungal dissemination to the brain. Our results demonstrate the capacity of carbohydrate source and concentration to modify the expression of a major virulence factor of C. neoformans. These findings may impact the clinical management of cryptococcosis. PMID:20070311