Sample records for capture detector ecd

  1. Variable pressure ionization detector for gas chromatography

    DOEpatents

    Buchanan, Michelle V.; Wise, Marcus B.

    1988-01-01

    Method and apparatus for differentiating organic compounds based on their electron affinity. An electron capture detector cell (ECD) is operated at pressures ranging from atmospheric to less than 1 torr. Through variation of the pressure within the ECD cell, the organic compounds are induced to either capture or emit electrons. Differentiation of isomeric compounds can be obtianed when, at a given pressure, one isomer is in the emission mode and the other is in the capture mode. Output of the ECD is recorded by chromatogram. The invention also includes a method for obtaining the zero-crossing pressure of a compound, defined as the pressure at which the competing emission and capture reactions are balanced and which may be correlated to the electron affinity of a compound.

  2. Simultaneous determination of chlorinated organic compounds from environmental samples using gas chromatography coupled with a micro electron capture detector and micro-plasma atomic emission detector

    NASA Astrophysics Data System (ADS)

    Quan, Xie; Chen, Shuo; Platzer, Bernhard; Chen, Jingwen; Gfrerer, Marion

    2002-01-01

    Water and sediment samples were screened simultaneously for the presence of polychlorinated organic compounds using gas chromatography (GC) coupled with an micro electron capture detector (μ-ECD) and a newly developed helium plasma based on a micro-atomic emission detector (μ-AED). The GC column effluent was split 15:85 between two detectors. In this way, two chromatograms, one obtained by μ-ECD and another by μ-AED, were recorded simultaneously. α-, β-hexachlorocyclohexane and p, p'-DDE were detected. RSDs of the monitoring results from the two detection methods were <20% for the three compounds. A detection limit of 8.5 pg and at least 3 orders of magnitude of linear range for μ-AED was observed.

  3. Multiplexed electronically programmable multimode ionization detector for chromatography

    DOEpatents

    Wise, M.B.; Buchanan, M.V.

    1988-05-19

    Method and apparatus for detecting and differentiating organic compounds based on their electron affinity. An electron capture detector cell (ECD) is operated in a plurality of multiplexed electronically programmable operating modes to alter the detector response during a single sampling cycle to acquire multiple simultaneous chromatograms corresponding to each of the different operating modes. The cell is held at a constant subatmospheric pressure while the electron collection bias voltage applied to the cell is modulated electronically to allow acquisition of multiple chromatograms for a single sample elution from a chromatograph representing three distinctly different response modes. A system is provided which automatically controls the programmed application of bias pulses at different intervals and/or amplitudes to switch the detector from an ionization mode to the electron capture mode and various degrees therebetween to provide an improved means of tuning an ECD for multimode detection and improved specificity. 6 figs.

  4. Multiplexed electronically programmable multimode ionization detector for chromatography

    DOEpatents

    Wise, Marcus B.; Buchanan, Michelle V.

    1989-01-01

    Method and apparatus for detecting and differentiating organic compounds based on their electron affinity. An electron capture detector cell (ECD) is operated in a plurality of multiplexed electroncially programmable operating modes to alter the detector response during a single sampling cycle to acquire multiple simultaneous chromatograms corresponding to each of the different operating modes. The cell is held at a constant subatmospheric pressure while the electron collection bias voltage applied to the cell is modulated electronically to allow acquisition of multiple chromatograms for a single sample elution from a chromatograph representing three distinctly different response modes. A system is provided which automatically controls the programmed application of bias pulses at different intervals and/or amplitudes to switch the detector from an ionization mode to the electron capture mode and various degrees therebetween to provide an improved means of tuning an ECD for multimode detection and improved specificity.

  5. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR ANALYSIS OF PESTICIDE SAMPLES BY GC/ECD (BCO-L-24.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the methods used for detection and quantification by gas chromatography electron capture detector (GC/ECD) of pesticides in a variety of matrices, including air, house dust, soil, handwipes, and surface wipes. Other SOP's detail the extract...

  6. Midwife to the greens: the electron capture detector.

    PubMed

    Lovelock, J E

    1997-03-01

    James E. Lovelock makes an account of the path he has followed since he started his scientific research at the National Institute for Medical Research (NIMR) in London in the 1940s, emphasizing the aspects related to environmental sciences. Lovelock explains the origins of the electron capture detector (ECD). So far, the ECD is the most sensitive, easily portable and inexpensive analytical apparatus capable of detecting substances present in the atmosphere at concentrations as low as parts per trillion (10(-12)). It has been the first device specifically sensitive to pollutants, and its use has provided the grounds for the development of environmental sciences, and green politics. The data gathered by the ECD about the persistence of pesticides in the environment led American biologist Rachel Carson to write her seminal book Silent Spring; data regarding the global presence of chlorofluorocarbons (CFC) in the atmosphere led Sherwood Rowland and Mario Molina to develop their theory of ozone depletion. The results of his research over the years led Lovelock himself to the development of the Gaia theory.

  7. FIELD ANALYTICAL SCREENING PROGRAM: PCP METHOD - INNOVATIVE TECHNOLOGY EVALUATION REPORT

    EPA Science Inventory

    The Field Analytical Screening Program (FASP) pentachlorophenol (PCP) method uses a gas chromatograph (GC) equipped with a megabore capillary column and flame ionization detector (FID) and electron capture detector (ECD) to identify and quantify PCP. The FASP PCP method is design...

  8. Measurements of atmospheric carbonyl sulfide during the NASA Chemical Instrumentation Test and Evaluation Project: Implications for the global COS budget

    NASA Technical Reports Server (NTRS)

    Johnson, James E.; Bandy, Alan R.; Thornton, Donald C.; Bates, Timothy S.

    1993-01-01

    Atmospheric carbonyl sulfide COS concentrations were measured by three analytical systems during the Chemical Instrumentation Test and Evaluation (CITE 3) project. The three systems all used cryogenic sample preconcentration and gas chromatographic (GC) separation but differed in the method of detection. The FPD system used a flame photometric detector, the MS system used a mass selective detector, and the ECD-S system used a fluorinating catalyst followed by an electron capture detector. With the FPD system, we found a mean COS concentration of 510 ppt over the North Atlantic and 442 ppt over the Tropical Atlantic. With the ECD-S system, we found a mean COS concentration of 489 ppt over the North Atlantic and 419 ppt over the Tropical Atlantic. All three systems registered a latitudinal gradient in atmospheric COS of between 1.6 and 2.0 ppt per degree of latitude, with increasing COS concentrations northward which was similar to the gradient measured by Bingemer et al. (1990). It is difficult to reconcile the measured latitudinal concentration gradient with present theories of the global COS budget since the largest sink of COS is thought to be a flux to land plants, most of which are in the northern hemisphere.

  9. DEMONSTRATION BULLETIN: FIELD ANALYTICAL SCREENING PROGRAM: PCB METHOD - U.S. ENVIRONMENTAL PROTECTION AGENCY

    EPA Science Inventory

    The field analytical screening program (FASP) polychlorinated biphenyl (PCB) method uses a temperature-programmable gas chromatograph (GC) equipped with an electron capture detector (ECD) to identify and quantify PCBs. Gas chromatography is an EPA-approved method for determi...

  10. Benchmarking of candidate detectors for multiresidue analysis of pesticides by comprehensive two-dimensional gas chromatography.

    PubMed

    Engel, Erwan; Ratel, Jérémy; Blinet, Patrick; Chin, Sung-Tong; Rose, Gavin; Marriott, Philip J

    2013-10-11

    The present study discusses the relevance, performance and complementarities of flame photometric detector in phosphorus (FPD/P) and sulfur (FPD/S) modes, micro electron capture detector (μECD), nitrogen phosphorus detector (NPD), flame ionization detector (FID) and time-of-flight mass spectrometer (TOF/MS) for the comprehensive two-dimensional gas chromatography (GC×GC) analysis of pesticides. A mix of 41 pesticides including organophosphorus pesticides, synthetic pyrethroids and fungicides was investigated in order to benchmark GC×GC systems in terms of linearity (R(2)), limits of detection (LOD), and peak shape measures (widths and asymmetries). A mixture of pesticides which contained the heteroatoms phosphorus, sulfur, nitrogen and one or several halogens, was used to acquire a comparative data set to monitor relative detector performances. GC×GC datasets were systematically compared to their GC counterpart acquired with an optimized one-dimensional GC configuration. Compared with FID, considered the most appropriate detector in terms of suitability for GC×GC, the element-selective detector FPD/P and μECD best met the peak widths (0.13-0.27s for FPD/P; 0.22-0.26s for μECD) and tailing factors (0.99-1.66 for FPD/P; 1.32-1.52 for μECD); NPD exhibited similar peak widths (0.23-0.30s), but exceeded those of the above detectors for tailing factors (1.97-2.13). These three detectors had improved detection limits of 3-7 times and 4-20 times lower LODs in GC×GC mode compared with FID and TOF-MS, respectively. In contrast FPD/S had poor peak shape (tailing factor 3.36-5.12) and much lower sensitivity (10-20 fold lower compared to FPD/P). In general, element-selective detectors with favorable detection metrics can be considered viable alternatives for pesticide determination using GC×GC in complex matrices. The controversial issue of sensitivity enhancement in GC×GC was considered for optimized GC and GC×GC operation. For all detectors, we found no significant LOD enhancement in GC×GC. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Determination of iodopropynyl butylcarbamate in cosmetic formulations utilizing pulsed splitless injection, gas chromatography with electron capture detector.

    PubMed

    Palmer, Kevin B; LaFon, William; Burford, Mark D

    2017-09-22

    Current analytical methodology for iodopropynyl butylcarbamate (IPBC) analysis focuses on the use of liquid chromatography and mass spectrometer (LC-MS), but the high instrumentation and operator investment required has resulted in the need for a cost effective alternative methodology. Past publications investigating gas chromatography with electron capture detector (GC-ECD) for IPBC quantitation proved largely unsuccessful, likely due to the preservatives limited thermal stability. The use of pulsed injection techniques commonly used for trace analysis of thermally labile pharmaceutical compounds was successfully adapted for IPBC analysis and utilizes the selectivity of GC-ECD analysis. System optimization and sample preparation improvements resulted in substantial performance and reproducibility gains. Cosmetic formulations preserved with IPBC (50-100ppm) were solvated in toluene/isopropyl alcohol and quantified over the 0.3-1.3μg/ml calibration range. The methodology was robust (relative standard deviation 4%), accurate (98% recovery), and sensitive (limit of detection 0.25ng/ml) for use in routine testing of cosmetic formulation preservation. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Differential Mobility Spectrometry: Preliminary Findings on Determination of Fundamental Constants

    NASA Technical Reports Server (NTRS)

    Limero, Thomas; Cheng, Patti; Boyd, John

    2007-01-01

    The electron capture detector (ECD) has been used for 40+ years (1) to derive fundamental constants such as a compound's electron affinity. Given this historical perspective, it is not surprising that differential mobility spectrometry (DMS) might be used in a like manner. This paper will present data from a gas chromatography (GC)-DMS instrument that illustrates the potential capability of this device to derive fundamental constants for electron-capturing compounds. Potential energy curves will be used to provide possible explanation of the data.

  13. Measurement and Modeling of Ecosystem Risk and Recovery for In Situ Treatment of Contaminated Sediments

    DTIC Science & Technology

    2011-02-01

    µECD Gas chromatography - micro electron capture detector HPAH high molecular weight polyaromatic hydrocarbon HOC Hydrophobic organic compound IR...hydrocarbon PCB Polychlorinated biphenyl PE Polyethylene PED Polyethylene devices PFC Perfluorinated chemical POM Polyoxymethylene PRC...Performance reference compound RMSE Root Mean Squared Error SPME Solid Phase Micro Extraction SERDP Strategic Environmental Research and Development

  14. Two-dimensional on-line detection of brominated and iodinated volatile organic compounds by ECD and ICP-MS after GC separation.

    PubMed

    Schwarz, A; Heumann, K G

    2002-09-01

    Inductively coupled plasma-mass spectrometry (ICP-MS) was coupled to a gas chromatographic (GC) system with electron capture detector (ECD), which enables relatively easy characterization and quantification of brominated and iodinated (halogenated) volatile organic compounds (HVOCs) in aquatic and air samples. The GC-ECD system is connected in series with an ICP-MS by a directly heated transfer line and an outlet port-hole for elimination of the ECD make-up gas during ignition of the plasma. The hyphenated GC-ECD/ICP-MS system provides high selectivity and sensitivity for monitoring individual HVOCs under fast chromatographic conditions. The ECD is most sensitive for the detection of chlorinated and brominated but the ICP-MS for iodinated compounds. The greatest advantage of the use of an ICP-MS is its element-specific detection, which allows clear identification of compounds in most cases. The absolute detection limits for ICP-MS are 0.5 pg for iodinated, 10 pg for brominated, and 50 pg for chlorinated HVOCs with the additional advantage that calibration is almost independent on different compounds of the same halogen. In contrast to that detection limits for ECD vary for the different halogenated compounds and lie in the range of 0.03-11 pg. The two-dimensional GC-ECD/ICP-MS instrumentation is compared with electron impact mass spectrometry (EI-MS) and microwave induced plasma atomic emission detection (MIP-AED). Even if EI-MS has additional power in identifying unknown peaks by its scan mode, the detection limits are much higher compared with GC-ECD/ICP-MS, whereas the selective ion monitoring mode (SIM) reaches similar detection limits. The MIP-AED detection limits are at the same level as EI-MS in the scan mode.

  15. Validation of high-throughput measurement system with microwave-assisted extraction, fully automated sample preparation device, and gas chromatography-electron capture detector for determination of polychlorinated biphenyls in whale blubber.

    PubMed

    Fujita, Hiroyuki; Honda, Katsuhisa; Hamada, Noriaki; Yasunaga, Genta; Fujise, Yoshihiro

    2009-02-01

    Validation of a high-throughput measurement system with microwave-assisted extraction (MAE), fully automated sample preparation device (SPD), and gas chromatography-electron capture detector (GC-ECD) for the determination of polychlorinated biphenyls (PCBs) in minke whale blubber was performed. PCB congeners accounting for > 95% of the total PCBs burden in blubber were efficiently extracted with a small volume (20 mL) of n-hexane using MAE due to simultaneous saponification and extraction. Further, the crude extract obtained by MAE was rapidly purified and automatically substituted to a small volume (1 mL) of toluene using SPD without using concentrators. Furthermore, the concentration of PCBs in the purified and concentrated solution was accurately determined by GC-ECD. Moreover, the result of accuracy test using a certified material (SRM 1588b; Cod liver oil) showed good agreement with the NIST certified concentration values. In addition, the method quantification limit of total-PCB in whale blubbers was 41 ng g(-1). This new measurement system for PCBs takes only four hours. Consequently, it indicated this method is the most suitable for the monitoring and screening of PCBs in the conservation of the marine ecosystem and safe distribution of foods.

  16. Site Investigation Report. 161st Air Refueling Group, Arizona National Guard, Sky Harbor International Airport and Papago Military Reservation, Phoenix, Arizona. Volume 1. Report, Tables and Figures

    DTIC Science & Technology

    1992-11-01

    Tennessee 37831-7606 NTIS GP’A t managed by O-C T MARTIN MARIETTA ENERGY SYSTEMS, INC. for the U.S. DEPARTMENT OF ENERGY 1Y under contract DE -ACO5...conductivity ECD electron capture detector S K • , . , i F.xii S List of Acronyms (Continued) S EM electromagnetic induction Energy Systems Martin Marietta...Energy Sytems, Inc. EWA East Washington Area FID flame ionization detector 9 Fr/DAY feet per day FS feasibility scudy FSP field sampling plan GC gas

  17. Atypical behavior in the electron capture induced dissociation of biologically relevant transition metal ion complexes of the peptide hormone oxytocin

    NASA Astrophysics Data System (ADS)

    Kleinnijenhuis, Anne J.; Mihalca, Romulus; Heeren, Ron M. A.; Heck, Albert J. R.

    2006-07-01

    Doubly protonated ions of the disulfide bond containing nonapeptide hormone oxytocin and oxytocin complexes with different transition metal ions, that have biological relevance under physiological conditions, were subjected to electron capture dissociation (ECD) to probe their structural features in the gas phase. Although, all the ECD spectra were strikingly different, typical ECD behavior was observed for complexes of the nonapeptide hormone oxytocin with Ni2+, Co2+ and Zn2+, i.e., abundant c/z' and a'/y backbone cleavages and ECD characteristic S-S and S-C bond cleavages were observed. We propose that, although in the oxytocin-transition metal ion complexes the metal ions serve as the main initial capture site, the captured electron is transferred to other sites in the complex to form a hydrogen radical, which drives the subsequent typical ECD fragmentations. The complex of oxytocin with Cu2+ displayed noticeably different ECD behavior. The fragment ions were similar to fragment ions typically observed with low-energy collision induced dissociation (CID). We propose that the electrons captured by the oxytocin-Cu2+ complex might be favorably involved in reducing the Cu2+ metal ion to Cu+. Subsequent energy redistribution would explain the observed low-energy CID-type fragmentations. Electron capture resulted also in quite different specific cleavage sites for the complexes of oxytocin with Ni2+, Co2+ and Zn2+. This is an indication for structural differences in these complexes possibly linked to their significantly different biological effects on oxytocin-receptor binding, and suggests that ECD may be used to study subtle structural differences in transition metal ion-peptide complexes.

  18. NMT - A new individual ion counting method: Comparison to a Faraday cup

    NASA Astrophysics Data System (ADS)

    Burton, Michael; Gorbunov, Boris

    2018-03-01

    Two sample detectors used to analyze the emission from Gas Chromatography (GC) columns are the Flame Ionization Detector (FID) and the Electron Capture Detector (ECD). Both of these detectors involve ionization of the sample molecules and then measuring electric current in the gas using a Faraday cup. In this paper a newly discovered method of ion counting, Nanotechnology Molecular Tagging (NMT) is tested as a replacement to the Faraday cup in GCs. In this method the effective physical volume of individual molecules is enlarged up to 1 billion times enabling them to be detected by an optical particle counter. It was found that the sensitivity of NMT was considerably greater than the Faraday cup. The background in the NMT was circa 200 ions per cm3, corresponding to an extremely low electric current ∼10-17 A.

  19. Development of an in situ gas chromatograph - mass selective detector for the purpose of studying long-range pollution transport from Asia

    NASA Astrophysics Data System (ADS)

    Neu, J. L.; Daube, B. C.; Moore, F. L.; Dutton, G. S.; Hall, B. D.; Elkins, J. W.

    2003-12-01

    In September 2002, we began work on the development and construction of an automated, 3 channel gas chromatograph (GC) with a mass selective detector (MSD) and two electron capture detectors (ECDs). The instrument will be placed at a Pacific CMDL station (Mauna Loa or Trinidad Head), and will make continuous measurements of a variety of chemical species with a wide range of lifetimes, including chloroflourocarbons (CFCs), hydrochlorofluorocarbons (HCFCs), hydrofluorocarbons (HFCs), methyl halides, non-methane hydrocarbons (NMHCs), peroxyacetyl nitrate (PAN), nitrous oxide, and sulfur hexafluoride. The primary goal is to characterize the episodic long-range transport of pollution from Asia. We have completed development of a cryogenic trapping system for pre-concentrating samples for the MSD channel. We present a comparison and characterization of two types of traps, one with a one-inch section of Porapak Q as the adsorbent material, and one with 6 mg of Carboxen 1003 and 4 mg of Carboxen 1000. We discuss the suitability of each of these traps for our intended research. We also present our progress on other aspects of the measurement system, including a dynamic dilution system for calibration of PAN measurements on one of the ECD channels, and a discussion of the science issues involved in choosing the deployment location.

  20. Enantioselective determination of the organochlorine pesticide bromocyclen in spiked fish tissue using solid-phase microextraction coupled to gas chromatography with ECD and ICP-MS detection.

    PubMed

    Fidalgo-Used, Natalia; Montes-Bayón, Maria; Blanco-González, Elisa; Sanz-Medel, Alfredo

    2008-05-15

    A method for enantioselective determination of bromocyclen enantiomers in fish tissue has been developed. The enantiomers were resolved by capillary gas chromatography (GC) using a commercial chiral column (CP-Chirasil-Dex CB) and a temperature program from 50 degrees C (held for 1 min), raised to 140 degrees C at 40 degrees C min(-1) and then raised at 0.2 degrees C min(-1) to 155 degrees C. This enantioselective gas chromatographic separation was combined with a clean-up/enrichment procedure based on solid-phase microextraction (SPME). Under SPME optimized conditions, precision, linearity range and detection limits of the developed SPME-enantioselective GC procedure were evaluated and compared using two different detection systems: a classical electron-capture detection (ECD) and an element specific detection using inductively coupled plasma mass spectrometry (ICP-MS). The SPME-GC-ECD method exhibited an excellent sensitivity, with detection limits of 0.2 ng L(-1) for each enantiomer of bromocyclen. Although ICP-MS offered poorer detection limits (7 ng L(-1) as Br, equivalent to 36 ng L(-1) of each enantiomer) than conventional ECD detector, it proved to be clearly superior in terms of selectivity. The relative potential and performance of the two compared methods for real-life analysis has been illustrated by the determination of enantiomers of bromocyclen in spiked tissue extracts of trout.

  1. Multivariate Optimization for Extraction of Pyrethroids in Milk and Validation for GC-ECD and CG-MS/MS Analysis

    PubMed Central

    Zanchetti Meneghini, Leonardo; Rübensam, Gabriel; Claudino Bica, Vinicius; Ceccon, Amanda; Barreto, Fabiano; Flores Ferrão, Marco; Bergold, Ana Maria

    2014-01-01

    A simple and inexpensive method based on solvent extraction followed by low temperature clean-up was applied for determination of seven pyrethroids residues in bovine raw milk using gas chromatography coupled to tandem mass spectrometry (GC-MS/MS) and gas chromatography with electron-capture detector (GC-ECD). Sample extraction procedure was established through the evaluation of seven different extraction protocols, evaluated in terms of analyte recovery and cleanup efficiency. Sample preparation optimization was based on Doehlert design using fifteen runs with three different variables. Response surface methodologies and polynomial analysis were used to define the best extraction conditions. Method validation was carried out based on SANCO guide parameters and assessed by multivariate analysis. Method performance was considered satisfactory since mean recoveries were between 87% and 101% for three distinct concentrations. Accuracy and precision were lower than ±20%, and led to no significant differences (p < 0.05) between results obtained by GC-ECD and GC-MS/MS techniques. The method has been applied to routine analysis for determination of pyrethroid residues in bovine raw milk in the Brazilian National Residue Control Plan since 2013, in which a total of 50 samples were analyzed. PMID:25380457

  2. Mechanistic Study on Electron Capture Dissociation of the Oligosaccharide-Mg2+ Complex

    NASA Astrophysics Data System (ADS)

    Huang, Yiqun; Pu, Yi; Yu, Xiang; Costello, Catherine E.; Lin, Cheng

    2014-08-01

    Electron capture dissociation (ECD) has shown great potential in structural characterization of glycans. However, our current understanding of the glycan ECD process is inadequate for accurate interpretation of the complex glycan ECD spectra. Here, we present the first comprehensive theoretical investigation on the ECD fragmentation behavior of metal-adducted glycans, using the cellobiose-Mg2+ complex as the model system. Molecular dynamics simulation was carried out to determine the typical glycan-Mg2+ binding patterns and the lowest-energy conformer identified was used as the initial geometry for density functional theory-based theoretical modeling. It was found that the electron is preferentially captured by Mg2+ and the resultant Mg+• can abstract a hydroxyl group from the glycan moiety to form a carbon radical. Subsequent radical migration and α-cleavage(s) result in the formation of a variety of product ions. The proposed hydroxyl abstraction mechanism correlates well with the major features in the ECD spectrum of the Mg2+-adducted cellohexaose. The mechanism presented here also predicts the presence of secondary, radical-induced fragmentation pathways. These secondary fragment ions could be misinterpreted, leading to erroneous structural determination. The present study highlights an urgent need for continuing investigation of the glycan ECD mechanism, which is imperative for successful development of bioinformatics tools that can take advantage of the rich structural information provided by ECD of metal-adducted glycans.

  3. A quantification method for peroxyacetyl nitrate (PAN) using gas chromatography (GC) with a non-radioactive pulsed discharge detector (PDD)

    NASA Astrophysics Data System (ADS)

    Zhang, Lei; Jaffe, Daniel A.; Gao, Xin; McClure, Crystal D.

    2018-04-01

    In this study, we developed a method for continuous PAN measurements by gas chromatography (GC) with a non-radioactive pulsed discharge detector (PDD). Operational parameters were optimized based on the ratio of peak height over baseline noise (P/N ratio). The GC/PDD system was compared with a traditional radioactive electron-capture detector (ECD). In the lab, the method detection limit (MDL) of the new GC/PDD method (9 pptv) was lower than the radioactive GC/ECD method (15 pptv), demonstrating its excellent potential. The MDL of GC/PDD in the field campaign at the Mt. Bachelor Observatory (MBO) was 23 pptv, higher than in the lab. This was caused in part by the decreased slope of the calibration curve resulting from the low air pressure level at MBO. However, the MDL level of GC/PDD at MBO is still low enough for accurate PAN measurements, although special attention should be paid to its application at high-elevation sites. Observations of PAN were conducted at MBO in the summer of 2016 with the GC/PDD system, and provided more evidence of the performance of the system. PAN was found to be highly correlated with CO. The promising performance of GC/PDD which does not require a radioactive source makes it a useful approach for accurate PAN measurements in the field.

  4. The Impact of Phosphorylation on Electron Capture Dissociation of Proteins: A Top-Down Perspective

    NASA Astrophysics Data System (ADS)

    Chen, Bifan; Guo, Xiao; Tucholski, Trisha; Lin, Ziqing; McIlwain, Sean; Ge, Ying

    2017-09-01

    Electron capture dissociation (ECD) is well suited for the characterization of phosphoproteins, with which labile phosphate groups are generally preserved during the fragmentation process. However, the impact of phosphorylation on ECD fragmentation of intact proteins remains unclear. Here, we have performed a systematic investigation of the phosphorylation effect on ECD of intact proteins by comparing the ECD cleavages of mono-phosphorylated α-casein, multi-phosphorylated β-casein, and immunoaffinity-purified phosphorylated cardiac troponin I with those of their unphosphorylated counterparts, respectively. In contrast to phosphopeptides, phosphorylation has significantly reduced deleterious effects on the fragmentation of intact proteins during ECD. On a global scale, the fragmentation patterns are highly comparable between unphosphorylated and phosphorylated precursors under the same ECD conditions, despite a slight decrease in the number of fragment ions observed for the phosphorylated forms. On a local scale, single phosphorylation of intact proteins imposes minimal effects on fragmentation near the phosphorylation sites, but multiple phosphorylations in close proximity result in a significant reduction of ECD bond cleavages. [Figure not available: see fulltext.

  5. Electron capture dissociation in a branched radio-frequency ion trap.

    PubMed

    Baba, Takashi; Campbell, J Larry; Le Blanc, J C Yves; Hager, James W; Thomson, Bruce A

    2015-01-06

    We have developed a high-throughput electron capture dissociation (ECD) device coupled to a quadrupole time-of-flight mass spectrometer using novel branched radio frequency ion trap architecture. With this device, a low-energy electron beam can be injected orthogonally into the analytical ion beam with independent control of both the ion and electron beams. While ions and electrons can interact in a "flow-through" mode, we observed a large enhancement in ECD efficiency by introducing a short ion trapping period at the region of ion and electron beam intersection. This simultaneous trapping mode still provides up to five ECD spectra per second while operating in an information-dependent acquisition workflow. Coupled to liquid chromatography (LC), this LC-ECD workflow provides good sequence coverage for both trypsin and Lys C digests of bovine serum albumin, providing ECD spectra for doubly charged precursor ions with very good efficiency.

  6. Minimizing thermal degradation in gas chromatographic quantitation of pentaerythritol tetranitrate.

    PubMed

    Lubrano, Adam L; Field, Christopher R; Newsome, G Asher; Rogers, Duane A; Giordano, Braden C; Johnson, Kevin J

    2015-05-15

    An analytical method for establishing calibration curves for the quantitation of pentaerythriol tetranitrate (PETN) from sorbent-filled thermal desorption tubes by gas chromatography with electron capture detection (TDS-GC-ECD) was developed. As PETN has been demonstrated to thermally degrade under typical GC instrument conditions, peaks corresponding to both PETN degradants and molecular PETN are observed. The retention time corresponding to intact PETN was verified by high-resolution mass spectrometry with a flowing atmospheric pressure afterglow (FAPA) ionization source, which enabled soft ionization of intact PETN eluting the GC and subsequent accurate-mass identification. The GC separation parameters were transferred to a conventional GC-ECD instrument where analytical method-induced PETN degradation was further characterized and minimized. A method calibration curve was established by direct liquid deposition of PETN standard solutions onto the glass frit at the head of sorbent-filled thermal desorption tubes. Two local, linear relationships between detector response and PETN concentration were observed, with a total dynamic range of 0.25-25ng. Published by Elsevier B.V.

  7. Electron capture dissociation of polypeptides using a 3 Tesla Fourier transform ion cyclotron resonance mass spectrometer.

    PubMed

    Polfer, Nicolas C; Haselmann, Kim F; Zubarev, Roman A; Langridge-Smith, Pat R R

    2002-01-01

    Electron capture dissociation (ECD) of polypeptides has been demonstrated using a commercially available 3 Tesla Fourier transform ion cyclotron resonance (FTICR) instrument. A conventional rhenium filament, designed for high-energy electron impact ionisation, was used to effect ECD of substance P, bee venom melittin and bovine insulin, oxidised B chain. A retarding field analysis of the effective electron kinetic energy distribution entering the ICR cell suggests that one of the most important parameters governing ECD for this particular instrument is the need to employ low trapping plate voltages. This is shown to maximise the abundance of low-energy electrons. The demonstration of ECD at this relatively low magnetic field strength could offer the prospect of more routine ECD analysis for the wider research community, given the reduced cost of such magnets and (at least theoretically) the greater ease of electron/ion cloud overlap at lower field. Copyright 2002 John Wiley & Sons, Ltd.

  8. Development of a method for the determination of 9 currently used cotton pesticides by gas chromatography with electron capture detection.

    PubMed

    Zhang, Baohong; Pan, Xiaoping; Venne, Louise; Dunnum, Suzy; McMurry, Scott T; Cobb, George P; Anderson, Todd A

    2008-05-30

    A reliable, sensitive, and reproducible method was developed for quantitative determination of nine new generation pesticides currently used in cotton agriculture. Injector temperature significantly affected analyte response as indicated by electron capture detector (ECD) chromatograms. A majority of the analytes had an enhanced response at injector temperatures between 240 and 260 degrees C, especially analytes such as acephate that overall had a poor response on the ECD. The method detection limits (MDLs) were 0.13, 0.05, 0.29, 0.35, 0.08, 0.10, 0.32, 0.05, and 0.59 ng/mL for acephate, trifuralin, malathion, thiamethozam, pendimethalin, DEF6, acetamiprid, brifenthrin, and lambda-cyhalothrin. This study provides a precision (0.17-13.1%), accuracy (recoveries=88-107%) and good reproducible method for the analytes of interest. At relatively high concentrations, only lambda-cyhalothrin was unstable at room temperature (20-25 degrees C) and 4 degrees C over 10 days. At relatively low concentrations, acephate and acetamiprid were also unstable regardless of temperature. After 10 days storage at room temperature, 30-40% degradation of lambda-cyhalothrin was observed. It is recommended that acephate, acetamiprid, and lambda-cyhalothrin be stored at -20 degrees C or analyzed immediately after extraction.

  9. Direct Determination of ECD in ECD Kit: A Solid Sample Quantitation Method for Active Pharmaceutical Ingredient in Drug Product

    PubMed Central

    Chao, Ming-Yu; Liu, Kung-Tien; Hsia, Yi-Chih; Liao, Mei-Hsiu; Shen, Lie-Hang

    2011-01-01

    Technetium-99m ethyl cysteinate dimer (Tc-99m-ECD) is an essential imaging agent used in evaluating the regional cerebral blood flow in patients with cerebrovascular diseases. Determination of active pharmaceutical ingredient, that is, L-Cysteine, N, N′-1,2-ethanediylbis-, diethyl ester, dihydrochloride (ECD) in ECD Kit is a relevant requirement for the pharmaceutical quality control in processes of mass fabrication. We here presented a direct solid sample determination method of ECD in ECD Kit without sample dissolution to avoid the rapid degradation of ECD. An elemental analyzer equipped with a nondispersive infrared detector and a calibration curve of coal standard was used for the quantitation of sulfur in ECD Kit. No significant matrix effect was found. The peak area of coal standard against the amount of sulfur was linear over the range of 0.03–0.10 mg, with a correlation coefficient (r) of 0.9993. Method validation parameters were achieved to demonstrate the potential of this method. PMID:21687539

  10. Pesticide residues in raspberries (Rubus idaeus L.) and dietary risk assessment.

    PubMed

    Łozowicka, B; Kaczyński, P; Jankowska, M; Rutkowska, E; Hrynko, I

    2012-01-01

    The aim of this study was to evaluate the residues of 140 pesticides in raspberries from north-eastern Poland (2005-2010). Gas chromatography with electron capture detector (GC-ECD) and nitrogen phosphorous detector (GC-NPD) was used. Among the 128 samples, 66 (51.6%) were found to detect residues: 14.1% contained one pesticide and around 38% multiple pesticide residues. The most frequently detected were pyrimethanil residues (36.0%). Twenty-seven (21.1%) raspberry samples exceeded the maximum residue limits. The estimated daily intakes ranged from 0.003% to 3.183% of the acceptable daily intake (ADI) for adults 0.008% and 9.7% for toddlers, respectively. The most critical case is procymidone, the acute risk was 180.9% of acute reference dose (ARfD) for toddlers and for adults (83% of ARfD) which is high.

  11. Quantifying Residues from Postharvest Propylene Oxide Fumigation of Almonds and Walnuts.

    PubMed

    Jimenez, Leonel R; Hall, Wiley A; Rodriquez, Matthew S; Cooper, William J; Muhareb, Jeanette; Jones, Tom; Walse, Spencer S

    2015-01-01

    A novel analytical approach involving solvent extraction with methyl tert-butyl ether (MTBE) followed by GC was developed to quantify residues that result from the postharvest fumigation of almonds and walnuts with propylene oxide (PPO). Verification and quantification of PPO, propylene chlorohydrin (PCH) [1-chloropropan-2-ol (PCH-1) and 2-chloropropan-1-ol (PCH-2)], and propylene bromohydrin (PBH) [1-bromopropan-2-ol (PBH-1) and 2-bromopropan-1-ol (PBH-2)] was accomplished with a combination of electron impact ionization MS (EIMS), negative ion chemical ionization MS (NCIMS), and electron capture detection (ECD). Respective GC/EIMS LOQs for PPO, PCH-1, PCH-2, PBH-1, and PBH-2 in MTBE extracts were [ppm (μg/g nut)] 0.9, 2.1, 2.5, 30.3, and 50.0 for almonds and 0.8, 2.2, 2.02, 41.6, and 45.7 for walnuts. Relative to GC/EIMS, GC-ECD analyses resulted in no detection of PPO, similar detector responses for PCH isomers, and >100-fold more sensitive detection of PBH isomers. NCIMS did not enhance detection of PBH isomers relative to EIMS and was, respectively, approximately 20-, 5-, and 10-fold less sensitive to PPO, PCH-1, and PCH-2. MTBE extraction efficiencies were >90% for all analytes. The 10-fold concentration of MTBE extracts yielded recoveries of 85-105% for the PBH isomers and a concomitant decrease in LODs and LOQs across detector types. The recoveries of PCH isomers and PPO in the MTBE concentrate were relatively low (approximately 50 to 75%), which confound improvements in LODs and LOQs regardless of detector type.

  12. A real time sorbent based air monitoring system for determining low level airborne exposure levels to Lewisite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lattin, F.G.; Paul, D.G.; Jakubowski, E.M.

    1994-12-31

    The Real Time Analytical Platform (RTAP) is designed to provide mobile, real-time monitoring support to ensure protection of worker safety in areas where military unique compounds are used and stored, and at disposal sites. Quantitative analysis of low-level vapor concentrations in air is accomplished through sorbent-based collection with subsequent thermal desorption into a gas chromatograph (GC) equipped with a variety of detectors. The monitoring system is characterized by its sensitivity (ability to measure at low concentrations), selectivity (ability to filter out interferences), dynamic range and linearity, real time mode (versus methods requiring extensive sample preparation procedures), and ability to interfacemore » with complimentary GC detectors. This presentation describes an RTAP analytical method for analyzing lewisite, an arsenical compound, that consists of a GC screening technique with an Electron Capture Detector (ECD), and a confirmation technique using an Atomic Emission Detector (AED). Included in the presentation is a description of quality assurance objectives in the monitoring system, and an assessment of method accuracy, precision and detection levels.« less

  13. Probing Protein Structure and Folding in the Gas Phase by Electron Capture Dissociation

    NASA Astrophysics Data System (ADS)

    Schennach, Moritz; Breuker, Kathrin

    2015-07-01

    The established methods for the study of atom-detailed protein structure in the condensed phases, X-ray crystallography and nuclear magnetic resonance spectroscopy, have recently been complemented by new techniques by which nearly or fully desolvated protein structures are probed in gas-phase experiments. Electron capture dissociation (ECD) is unique among these as it provides residue-specific, although indirect, structural information. In this Critical Insight article, we discuss the development of ECD for the structural probing of gaseous protein ions, its potential, and limitations.

  14. Enhancing Protein Disulfide Bond Cleavage by UV Excitation and Electron Capture Dissociation for Top-Down Mass Spectrometry.

    PubMed

    Wongkongkathep, Piriya; Li, Huilin; Zhang, Xing; Loo, Rachel R Ogorzalek; Julian, Ryan R; Loo, Joseph A

    2015-11-15

    The application of ion pre-activation with 266 nm ultraviolet (UV) laser irradiation combined with electron capture dissociation (ECD) is demonstrated to enhance top-down mass spectrometry sequence coverage of disulfide bond containing proteins. UV-based activation can homolytically cleave a disulfide bond to yield two separated thiol radicals. Activated ECD experiments of insulin and ribonuclease A containing three and four disulfide bonds, respectively, were performed. UV-activation in combination with ECD allowed the three disulfide bonds of insulin to be cleaved and the overall sequence coverage to be increased. For the larger sized ribonuclease A with four disulfide bonds, irradiation from an infrared laser (10.6 µm) to disrupt non-covalent interactions was combined with UV-activation to facilitate the cleavage of up to three disulfide bonds. Preferences for disulfide bond cleavage are dependent on protein structure and sequence. Disulfide bonds can reform if the generated radicals remain in close proximity. By varying the time delay between the UV-activation and the ECD events, it was determined that disulfide bonds reform within 10-100 msec after their UV-homolytic cleavage.

  15. Electron Capture Dissociation of Divalent Metal-adducted Sulfated N-Glycans Released from Bovine Thyroid Stimulating Hormone

    NASA Astrophysics Data System (ADS)

    Zhou, Wen; Håkansson, Kristina

    2013-11-01

    Sulfated N-glycans released from bovine thyroid stimulating hormone (bTSH) were ionized with the divalent metal cations Ca2+, Mg2+, and Co by electrospray ionization (ESI). These metal-adducted species were subjected to infrared multiphoton dissociation (IRMPD) and electron capture dissociation (ECD) and the corresponding fragmentation patterns were compared. IRMPD generated extensive glycosidic and cross-ring cleavages, but most product ions suffered from sulfonate loss. Internal fragments were also observed, which complicated the spectra. ECD provided complementary structural information compared with IRMPD, and all observed product ions retained the sulfonate group, allowing sulfonate localization. To our knowledge, this work represents the first application of ECD towards metal-adducted sulfated N-glycans released from a glycoprotein. Due to the ability of IRMPD and ECD to provide complementary structural information, the combination of the two strategies is a promising and valuable tool for glycan structural characterization. The influence of different metal ions was also examined. Calcium adducts appeared to be the most promising species because of high sensitivity and ability to provide extensive structural information.

  16. Determination of dichloroacetic acid and trichloroacetic acid in drinking water by acidic methanol esterification and headspace gas chromatography.

    PubMed

    Wang, Y H; Wong, P K

    2005-05-01

    A simple and rapid headspace method for gas chromatographic determination of dichloroacetic acid (DCAA) and trichloroacetic acid (TCAA) in drinking water was developed. Acidic methanol esterification followed by a headspace technique using a capillary column gas chromatograph (GC) equipped with an electron capture detector (ECD) was applied to determine the levels of DCAA and TCAA in drinking water. The major advantages of this method are the use of acidic methanol as the derivatization agent instead of the hazardous diazomethane, and esterification is carried out in water instead of organic solvent. DCAA and TCAA methyl esters produced in the reaction were determined directly by a headspace GC/ECD method. The linear correlation coefficients at concentrations ranging from 0 to 60 microg/L were 0.992 and 0.996 for DCAA and TCAA, respectively. The relative standard deviations (RSD, %) for the determination of DCAA and TCAA in drinking water were 15 and 21.3%, respectively (n=3). The detection limits of this method were 3 and 0.5 microg/L for DCAA and TCAA, respectively, and the recovery was 68-103.2% for DCAA and TCAA.

  17. Vertical migration of some herbicides through undisturbed and homogenized soil columns

    PubMed Central

    Aktar, Md. Wasim; Sengupta, Dwaipayan; Purkait, Swarnali; Chowdhury, Ashim

    2008-01-01

    A laboratory experiment was conducted by using three herbicides, two from dinitroaniline group and one from thiocarbamate group to know their degree of downward movement (leachability) through soil columns and their contribution in ground water contamination. Soil columns were loaded with Pendimethalin, Benthiocarb and Oryzalin at doses of 10.0, 10.0 and 7.7 kg/ha, respectively. After 30 days soil samples were analyzed from each segments (i.e. 0–6, 6–12, 12–18, 18–24 and 24–30 cm) for Benthiocarb and Pendimethalin by GLC equipped with Ni63 electron capture detector (ECD) and for Oryzalin by HPLC coupled with UV-VIS detector. The results obtained in the present study reveal that the residues of the three herbicides under investigation were predominantly confined to the upper soil layer (0–6 cm). Comparatively, low mobility of these herbicides in soils could be due to strong adsorption of these chemical to soil colloids. PMID:21218121

  18. Discrimination of smokeless powders by headspace SPME-GC-MS and SPME-GC-ECD, and the potential implications upon training canine detection of explosives

    NASA Astrophysics Data System (ADS)

    Harper, Ross J.; Almirall, Jose R.; Furton, Kenneth G.

    2005-05-01

    This presentation will provide an odour analysis of a variety of smokeless powders & communicate the rapid SPME-GC-ECD method utilized. This paper will also discuss the implications of the headspace analysis of Smokeless Powders upon the choice of training aids for Explosives Detection Canines. Canine detection of explosives relies upon the dogs" ability to equate finding a given explosive odour with a reward, usually in the form of praise or play. The selection of explosives upon which the dogs are trained thus determines which explosives the canines can and potentially cannot find. Commonly, the training is focussed towards high explosives such as TNT and Composition 4, and the low explosives such as Black and Smokeless Powders are added often only for completeness. Powder explosives constitute a major component of explosive incidents throughout the US, and canines trained to detect explosives must be trained across the entire range of powder products. Given the variability in the manufacture and product make-up many smokeless powders do not share common odour chemicals, giving rise to concerns over the extensiveness of canine training. Headspace analysis of a selection of Smokeless Powders by Solid Phase Microextraction Gas Chromatography using Mass Spectrometry (SPME-GC-MS) and Electron Capture Detectors (SPME-GC-ECD) has highlighted significant differences in the chemical composition of the odour available from different brands. This suggests that greater attention should be paid towards the choice of Powder Explosives when assigning canine training aids.

  19. Low-Level detections of halogenated volatile organic compounds in groundwater: Use in vulnerability assessments

    USGS Publications Warehouse

    Plummer, Niel; Busenberg, E.; Eberts, S.M.; Bexfield, L.M.; Brown, C.J.; Fahlquist, L.S.; Katz, B.G.; Landon, M.K.

    2008-01-01

    Concentrations of halogenated volatile organic compounds (VOCs) were determined by gas chromatography (GC) with an electron-capture detector (GC-ECD) and by gas chromatography with mass spectrometry (GC-MS) in 109 groundwater samples from five study areas in the United States. In each case, the untreated water sample was used for drinking-water purposes or was from a monitoring well in an area near a drinking-water source. The minimum detection levels (MDLs) for 25 VOCs that were identified in GC-ECD chromatograms, typically, were two to more than four orders of magnitude below the GC-MS MDLs. At least six halogenated VOCs were detected in all of the water samples analyzed by GC-ECD, although one or more VOCs were detected in only 43% of the water samples analyzed by GC-MS. In nearly all of the samples, VOC concentrations were very low and presented no known health risk. Most of the low-level VOC detections indicated post-1940s recharge, or mixtures of recharge that contained a fraction of post-1940s water. Concentrations of selected halogenated VOCs in groundwater from natural and anthropogenic atmospheric sources were estimated and used to recognize water samples that are being impacted by nonatmospheric sources. A classification is presented to perform vulnerability assessments at the scale of individual wells using the number of halogenated VOC detections and total dissolved VOC concentrations in samples of untreated drinking water. The low-level VOC detections are useful in vulnerability assessments, particularly for samples in which no VOCs are detected by GC-MS analysis.

  20. Mapping a Noncovalent Protein-Peptide Interface by Top-Down FTICR Mass Spectrometry Using Electron Capture Dissociation

    NASA Astrophysics Data System (ADS)

    Clarke, David J.; Murray, Euan; Hupp, Ted; Mackay, C. Logan; Langridge-Smith, Pat R. R.

    2011-08-01

    Noncovalent protein-ligand and protein-protein complexes are readily detected using electrospray ionization mass spectrometry (ESI MS). Furthermore, recent reports have demonstrated that careful use of electron capture dissociation (ECD) fragmentation allows covalent backbone bonds of protein complexes to be dissociated without disruption of noncovalent protein-ligand interactions. In this way the site of protein-ligand interfaces can be identified. To date, protein-ligand complexes, which have proven tractable to this technique, have been mediated by ionic electrostatic interactions, i.e., ion pair interactions or salt bridging. Here we extend this methodology by applying ECD to study a protein-peptide complex that contains no electrostatics interactions. We analyzed the complex between the 21 kDa p53-inhibitor protein anterior gradient-2 and its hexapeptide binding ligand (PTTIYY). ECD fragmentation of the 1:1 complex occurs with retention of protein-peptide binding and analysis of the resulting fragments allows the binding interface to be localized to a C-terminal region between residues 109 and 175. These finding are supported by a solution-phase competition assay, which implicates the region between residues 108 and 122 within AGR2 as the PTTIYY binding interface. Our study expands previous findings by demonstrating that top-down ECD mass spectrometry can be used to determine directly the sites of peptide-protein interfaces. This highlights the growing potential of using ECD and related top-down fragmentation techniques for interrogation of protein-protein interfaces.

  1. Separation of polychlorinated biphenyls by fast gas chromatography.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alvarado, J. S.; Silzer, J.; Lemley, F.

    1997-12-01

    The separation of commercially available polychlorinated biphenyls (PCBs) by fast gas chromatography (fast GC) has been studied. Aroclor 1254 was separated by using two column types: DB-1 and SPB-608. The fast GC used a split-splitless injector to introduce the sample, followed by a cold trap at -90 C to focus the sample. Rapid heating was used to introduce the sample into the short chromatographic column to decrease band broadening. Hydrogen was the carrier gas at velocities of 100 to 125 cm s-1. Analyses were performed by using an electron capture detector (ECD). Separation was achieved with both columns in lessmore » than 6 min. With the greatly shortened run times, reproducibility can be tested quickly and consequently with low cost.« less

  2. Methyl sulfonyl polychlorinated biphenyls and 2,2-bis(4-chlorophenyl)-1,1-dichlorethene in gray seal tissues determined by gas chromatography with electron capture detection and atomic emission detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Janak, K.; Becker, G.; Colmisjoe, A.

    1998-06-01

    The presence of 24 methyl sulfonyl polychlorinated biphenyl (PCB) congeners (MeSO{sub 2}-CBs) and 3-methyl sulfonyl 2,2-bis(4-chlorophenyl)-1,1-dichlorethene (DDE) (MeSO{sub 2}-DDE), metabolites of PCB and DDE, in blubber, lung, and liver of gray seals has been determined by using atomic emission detection (AED) and electron capture detection (ECD). Selective accumulation of aryl methyl sulfones in blubber, liver, and lung tissue was also investigated. For the liver samples, a substantial and highly specific retention of PCB methyl sulfones was observed. The atomic emission technique significantly improved the determination of measured solutes compared with ECD. Atomic emission detection was also valuable for the monitoringmore » of the prefractionation and to decrease the requirements of sample clean-up. Comparing both detection techniques showed a good correlation between the results of the AED sulfur-selective line and ECD.« less

  3. Effect of an electronic control device exposure on a methamphetamine-intoxicated animal model.

    PubMed

    Dawes, Donald M; Ho, Jeffrey D; Cole, Jon B; Reardon, Robert F; Lundin, Erik J; Terwey, Karen S; Falvey, Dan G; Miner, James R

    2010-04-01

    Because of the prevalence of methamphetamine abuse worldwide, it is not uncommon for subjects in law enforcement encounters to be methamphetamine-intoxicated. Methamphetamine has been present in arrest-related death cases in which an electronic control device (ECD) was used. The primary purpose of this study was to determine the cardiac effects of an ECD in a methamphetamine intoxication model. Sixteen anesthetized Dorset sheep (26-78 kg) received 0.0 mg/kg (control animals, n = 4), 0.5 mg/kg (n = 4), 1.0 mg/kg (n = 4), or 1.5 mg/kg (n = 4) of methamphetamine hydrochloride as a slow intravenous (IV) bolus during continuous cardiac monitoring. The animals received the following exposures in sequence from a TASER X26 ECD beginning at 30 minutes after the administration of the drug: 1) 5-second continuous exposure, 2) 15-second intermittent exposure, 3) 30-second intermittent exposure, and 4) 40-second intermittent exposure. Darts were inserted at the sternal notch and the cardiac apex, to a depth of 9 mm. Cardiac motion was determined by thoracotomy (smaller animals, < or = 32 kg) or echocardiography (larger animals, > 68 kg). Data were analyzed using descriptive statistics and chi-square tests. Animals given methamphetamine demonstrated signs of methamphetamine toxicity with tachycardia, hypertension, and atrial and ventricular ectopy in the 30-minute period immediately after administration of the drug. Smaller animals (n = 8, < or = 32 kg, mean = 29.4 kg) had supraventricular dysrhythmias immediately after the ECD exposures. Larger animals (n = 8, > 68 kg, mean = 72.4) had only sinus tachycardia after the exposures. One of the smaller animals had frequent episodes of ventricular ectopy after two exposures, including runs of delayed onset, nonsustained six- to eight-beat unifocal and multifocal ventricular tachycardia that spontaneously resolved. This animal had significant ectopy prior to the exposures as well. Thoracotomy performed on three smaller animals demonstrated cardiac capture during ECD exposure consistent with previous animal studies. In the larger animals, none of the methamphetamine-intoxicated animals demonstrated cardiac capture. Two control sheep showed evidence of capture similar to the smaller animals. No ventricular fibrillation occurred after the exposure in any animal. In smaller animals (32 kg or less), ECD exposure exacerbated atrial and ventricular irritability induced by methamphetamine intoxication, but this effect was not seen in larger, adult-sized animals. There were no episodes of ventricular fibrillation after exposure associated with ECD exposure in methamphetamine-intoxicated sheep.

  4. Native MS and ECD Characterization of a Fab-Antigen Complex May Facilitate Crystallization for X-ray Diffraction

    NASA Astrophysics Data System (ADS)

    Zhang, Ying; Cui, Weidong; Wecksler, Aaron T.; Zhang, Hao; Molina, Patricia; Deperalta, Galahad; Gross, Michael L.

    2016-07-01

    Native mass spectrometry (MS) and top-down electron-capture dissociation (ECD) combine as a powerful approach for characterizing large proteins and protein assemblies. Here, we report their use to study an antibody Fab (Fab-1)-VEGF complex in its near-native state. Native ESI with analysis by FTICR mass spectrometry confirms that VEGF is a dimer in solution and that its complex with Fab-1 has a binding stoichiometry of 2:2. Applying combinations of collisionally activated dissociation (CAD), ECD, and infrared multiphoton dissociation (IRMPD) allows identification of flexible regions of the complex, potentially serving as a guide for crystallization and X-ray diffraction analysis.

  5. Dissipation, half-lives, and mass spectrometric identification of chlorpyrifos and its two metabolites on field-grown collard and kale.

    PubMed

    Antonious, George F; Turley, Eric T; Abubakari, Mutari; Snyder, John C

    2017-04-03

    The persistence and fate of chlorpyrifos and its two metabolites, chlorpyrifos-oxon and the 3, 5, 6-trichloro-2-pyridinol (TCP) break-down product were investigated on kale and collard leaves under field conditions. A simultaneous extraction and quantification procedure was developed for chrorpyrifos and its two main metabolites. Residues of chlorpyrifos, chlorpyrifos oxon, and TCP were determined using a gas chromatograph (GC) equipped with an electron capture detector (GC/ECD). Chlorpyrifos metabolites were detectable up to 23 days following application. Residues were confirmed using a GC equipped with a mass selective detector (GC/MSD) in total ion mode. Initial residues of chlorpyrifos were greater on collard (14.5 µg g -1 ) than kale (8.2 µg g -1 ) corresponding to half-lives (T 1/2 ) values of 7.4 and 2.2 days, respectively. TCP, the hydrolysis product, was more persistent on collards with an estimated T 1/2 of 6.5 days compared to kale (T 1/2 of 1.9 days).

  6. Simultaneous analysis of organochlorine pesticides and polychlorinated biphenyls in air samples by using accelerated solvent extraction (ASE) and solid-phase micro-extraction (SPME) coupled to gas chromatography dual electron capture detection.

    PubMed

    Mokbel, Haifaa; Al Dine, Enaam Jamal; Elmoll, Ahmad; Liaud, Céline; Millet, Maurice

    2016-04-01

    An analytical method associating accelerated solvent extraction (ASE) and solid-phase micro-extraction (SPME) in immersion mode combined with gas chromatography dual electrons capture detectors (SPME-GC-2ECD) has been developed and studied for the simultaneous determination of 19 organochlorine pesticides (OCPs) and 22 polychlorinated biphenyls (PCBs) in air samples (active and XAD-2 passive samplers). Samples were extracted with ASE with acetonitrile using the following conditions: temperature, 150 °C; pressure, 1500 psi; static, 15 min; cycles, 3; purge, 300 s; flush, 100 %. Extracts were reduced to 1 mL, and 500 μL of this extract, filled with deionised water, was subject to SPME extraction. Experimental results indicated that the proposed method attained the best extraction efficiency under the optimised conditions: extraction of PCB-OCP mixture using 100-μm PDMS fibre at 80 °C for 40 min with no addition of salt. The performance of the proposed ASE-SPME-GC-2ECD methodology with respect to linearity, limit of quantification and detection was evaluated by spiking of XAD-2 resin with target compounds. The regression coefficient (R (2)) of most compounds was found to be high of 0.99. limits of detection (LODs) are between 0.02 and 4.90 ng m(-3), and limits of quantification (LOQs) are between 0.05 and 9.12 ng m(-3) and between 0.2 and 49 ng/sampler and 0.52 and 91 ng/sampler, respectively, for XAD-2 passive samplers. Finally, a developed procedure was applied to determine selected PCBs and OCPs in the atmosphere.

  7. Comparative study of different clean-up techniques for the determination of λ-cyhalothrin and cypermethrin in palm oil matrices by gas chromatography with electron capture detection.

    PubMed

    Muhamad, Halimah; Zainudin, Badrul Hisyam; Abu Bakar, Nor Kartini

    2012-10-15

    Solid phase extraction (SPE) and dispersive solid-phase extraction (d-SPE) were compared and evaluated for the determination of λ-cyhalothrin and cypermethrin in palm oil matrices by gas chromatography with an electron capture detector (GC-ECD). Several SPE sorbents such as graphitised carbon black (GCB), primary secondary amine (PSA), C(18), silica, and florisil were tested in order to minimise fat residues. The results show that mixed sorbents using GCB and PSA obtained cleaner extracts than a single GCB and PSA sorbents. The average recoveries obtained for each pesticide ranged between 81% and 114% at five fortification levels with the relative standard deviation of less than 7% in all cases. The limits of detection for these pesticides were ranged between 0.025 and 0.05 μg/g. The proposed method was applied successfully for the residue determination of both λ-cyhalothrin and cypermethrin in crude palm oil samples obtained from local mills throughout Malaysia. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Comparison of manual & automated analysis methods for corneal endothelial cell density measurements by specular microscopy.

    PubMed

    Huang, Jianyan; Maram, Jyotsna; Tepelus, Tudor C; Modak, Cristina; Marion, Ken; Sadda, SriniVas R; Chopra, Vikas; Lee, Olivia L

    2017-08-07

    To determine the reliability of corneal endothelial cell density (ECD) obtained by automated specular microscopy versus that of validated manual methods and factors that predict such reliability. Sharp central images from 94 control and 106 glaucomatous eyes were captured with Konan specular microscope NSP-9900. All images were analyzed by trained graders using Konan CellChek Software, employing the fully- and semi-automated methods as well as Center Method. Images with low cell count (input cells number <100) and/or guttata were compared with the Center and Flex-Center Methods. ECDs were compared and absolute error was used to assess variation. The effect on ECD of age, cell count, cell size, and cell size variation was evaluated. No significant difference was observed between the Center and Flex-Center Methods in corneas with guttata (p=0.48) or low ECD (p=0.11). No difference (p=0.32) was observed in ECD of normal controls <40 yrs old between the fully-automated method and manual Center Method. However, in older controls and glaucomatous eyes, ECD was overestimated by the fully-automated method (p=0.034) and semi-automated method (p=0.025) as compared to manual method. Our findings show that automated analysis significantly overestimates ECD in the eyes with high polymegathism and/or large cell size, compared to the manual method. Therefore, we discourage reliance upon the fully-automated method alone to perform specular microscopy analysis, particularly if an accurate ECD value is imperative. Copyright © 2017. Published by Elsevier España, S.L.U.

  9. Cation Recombination Energy/Coulomb Repulsion Effects in ETD/ECD as Revealed by Variation of Charge per Residue at Fixed Total Charge

    PubMed Central

    Mentinova, Marija; Crizer, David M.; Baba, Takashi; McGee, William M.; Glish, Gary L.; McLuckey, Scott A.

    2013-01-01

    Electron capture dissociation (ECD) and electron transfer dissociation (ETD) experiments in electrodynamic ion traps operated in the presence of a bath gas in the 1–10 mTorr range have been conducted on a common set of doubly protonated model peptides of the form X(AG)nX (X = lysine, arginine, or histidine, n=1, 2, or 4). The partitioning of reaction products was measured using thermal electrons, anions of azobenzene, and anions of 1,3-dinitrobenzene as reagents. Variation of n alters the charge per residue of the peptide cation, which affects recombination energy. The ECD experiments showed that H-atom loss is greatest for the n=1 peptides and decreases as n increases. Proton transfer in ETD, on the other hand, is expected to increase as charge per residue decreases (i.e., as n increases). These opposing tendencies were apparent in the data for the K(AG)nK peptides. H-atom loss appeared to be more prevalent in ECD than in ETD and is rationalized on the basis of either internal energy differences, differences in angular momentum transfer associated with the electron capture versus electron transfer processes, or a combination of the two. The histidine peptides showed the greatest extent of charge reduction without dissociation, the arginine peptides showed the greatest extent of side-chain cleavages, and the lysine peptides generally showed the greatest extent of partitioning into the c/z•-product ion channels. The fragmentation patterns for the complementary c- and z•-ions for ETD and ECD were found to be remarkably similar, particularly for the peptides with X = lysine. PMID:23568028

  10. Validation of the analytical method for the simultaneous determination of selected polybrominated diphenyl ethers, polychlorinated biphenyls and organochlorine pesticides in human blood serum by gas chromatography with microelectron capture detector.

    PubMed

    Matuszak, Małgorzata; Minorczyk, Maria; Góralczyk, Katarzyna; Hernik, Agnieszka; Struciński, Paweł; Liszewska, Monika; Czaja, Katarzyna; Korcz, Wojciech; Łyczewska, Monika; Ludwicki, Jan K

    2016-01-01

    Polybrominated diphenyl ethers (PBDEs) as other persistent organic pollutants like polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) pose a significant hazard to human health, mainly due to interference with the endocrine system and carcinogenetic effects. Humans are exposed to these substances mainly through a food of animal origin. These pollutants are globally detected in human matrices which requires to dispose reliable and simple analytical method that would enable further studies to assess the exposure of specific human populations to these compounds. The purpose of this study was to modify and validate of the analytical procedure for the simultaneous determination of selected PBDEs, PCBs and OCPs in human blood serum samples. The analytical measurement was performed by GC-µECD following preparation of serum samples (denaturation, multiple extraction, lipid removal). Identity of the compounds was confirmed by GC-MS. The method was characterised by the appropriate linearity, good repeatability (CV below 20%). The recoveries ranged from 52.9 to 125.0% depending on compound and level of fortification. The limit of quantification was set at 0.03 ng mL(-1) of serum. The modified analytical method proved to be suitable for the simultaneous determination of selected PBDEs, PCBs and OCPs in human blood serum by GC-µECD with good precision.

  11. 76 FR 55804 - Dicamba; Pesticide Tolerances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-09

    ... Considerations A. Analytical Enforcement Methodology Adequate enforcement methodologies, Methods I and II--gas chromatography with electron capture detection (GC/ECD), are available to enforce the tolerance expression. The...

  12. Exploring Hydrofluorocarbons as Groundwater Age Tracers (Invited)

    NASA Astrophysics Data System (ADS)

    Haase, K. B.; Busenberg, E.; Plummer, L. N.; Casile, G.; Sanford, W. E.

    2013-12-01

    Groundwater dating tracers are an essential tool for analyzing hydrologic conditions in groundwater systems. Commonly used tracers for dating post-1940's groundwater include sulfur hexafluoride (SF6), chlorofluorocarbons (CFCs), 3H-3He, and other isotopic tracers (85Kr, δ2H and δ18O isotopes, etc.). Each tracer carries a corresponding set of advantages and limitations imposed by field, analytical, and interpretive methods. Increasing the number available tracers is appealing, particularly if they possess inert chemical properties and unique temporal emission histories from other tracers. Atmospherically derived halogenated trace gases continue to hold untapped potential for new tracers, as they are generally inert and their emission histories are well documented. SF5CF3, and CFC-13 were previously shown to have application as dating tracers, though their low mixing ratios and low solubility require large amounts of water to be degassed for their quantification. Two related groups of compounds, hydrochlorofluorocarbons (HCFCs) and hydrofluorocarbons (HFCs) are hypothesized to be potential age tracers, having similar mixing ratios to the CFCs and relatively high solubility. However, these compounds yield gas chromatography electron capture detector (GC-ECD) responses that are 10-2 -10-5 less than CFC-12, making purge and trap or field stripping GC-ECD approaches impractical. Therefore, in order to use dissolved HCFCs and HFCs as age tracers, different approaches are needed. To solve this problem, we developed an analytical method that uses an atomic emission detector (GC-AED) in place of an ECD to detect fluorinated compounds. In contrast to the ECD, the AED is a universally sensitive, highly linear, elementally specific detector. The new GC-AED system is being used to measure chlorodifluoromethane (HCFC-22), 1,1,1,2-tetrafluoroethane (HFC-134a), and other fluorinated compounds in one liter water samples to study their potential as age dating tracers. HCFC-22 is a refrigerant introduced in the 1940's, with atmospheric mixing ratios increasing through the 1990s to the present value of ≈230 pptv. HFC-134a is typically is used as a chlorine-free replacement for CFC-12, finding use in air-condition systems and as an inert aerosol blowing agent, with a mixing ratio that has increased from <1 in 1994 to ≈75 pptv at present (2013). Their unique atmospheric histories and chemistry compared to CFCs makes these compounds interesting age tracer candidates, particularly in situations where multiple tracers enhance interpretive value. For instance, inclusion in lumped parameter mixing models and in situations where SF6 or the CFCs are present in elevated concentrations from non-atmospheric sources such that they cannot be used for dating purposes. Analysis of standards, air equilibrated water, and blanks suggests the GC-AED system is capable of detecting concentrations ≈200 fM (HCFC-22) and ≈100 fM (HFC-134a), corresponding to piston flow ages of 54 and 18 yr, respectively, with a typical uncertainty of ≈1 yr. Preliminary comparisons with CFC and SF6 analyses show general agreement between the techniques (within a few years), and ongoing intercomparison studies will be discussed.

  13. Determination of Pyrethroids through Liquid-Liquid Extraction and GC-ECD

    NASA Astrophysics Data System (ADS)

    Ding, B.

    2010-12-01

    Storm water samples from various locations in San Diego Creek and Newport Bay watershed, southern California, were taken to study the occurrence and fate of pyrethroids. This study focused on four commonly used pyrethroids: bifenthrin, cypermethrin, permethrin, and fenpropathrin. Since the ban of DDT, usage of pyrethroids became an effective second choice. However, pyrethroids are extremely toxic to fish and aquatic organisms. They can pass through secondary wastewater treatment system, causing the final effluent to be in lethal doses to aquatic invertebrates and some insects such as mayflies. Hence, it is necessary to monitor the amount of pyrethroid concentration in storm water. As a part of this study, I attended the RISE internship program at Stanford University in this summer. In the seven weeks, I learned liquid-liquid extraction, water-bath evaporation, nitrogen evaporation, and gas chromatography-electron capture detector techniques to extract and detect the pyrethroid residues in the water sample.

  14. Determination of 3-hydroxypropylmercapturic acid in urine by three column-switching high-performance liquid chromatography with electrochemical detection using a diamond electrode.

    PubMed

    Higashi, Kyohei; Shibasaki, Mana; Kuni, Kyoshiro; Uemura, Takeshi; Waragai, Masaaki; Uemura, Kenichi; Igarashi, Kazuei; Toida, Toshihiko

    2017-09-29

    A three column-switching high-performance liquid chromatography (HPLC) using an electrochemical detector (ECD) equipped with a diamond electrode was established to determine 3-hydroxypropylmercapturic acid (3-HPMA) in urine. An extracted urine sample was consecutively fractionated using a strong anion-exchange column (first column) and a C8 column (second column) via a switching valve before application on an Octa Decyl Silyl (ODS) column (third column), followed by ECD analysis. The% recovery of 3-HPMA standard throughout the three-column process and limit of detection (LOD) were 94±1% and 0.1pmol, respectively. A solid phase extraction step is required for the sensitive analysis of 3-HPMA in urine by column-switching HPLC-ECD despite a decreased% recovery (55%) of urine sample spiked with 100pmol of 3-HPMA. To test the utility of our column-switching HPLC-ECD method, 3-HPMA levels of 27 urine samples were determined, and the correlation between HPLC-ECD and LC-Electrospray ionization (ESI)-MS/MS method was examined. As a result, the median values of μmol 3-HPMA/g Creatinine (Cre) in urine obtained by column-switching HPLC-ECD and LC-MS/MS were 2.19±2.12μmol/g Cre and 2.13±3.38μmol/g Cre, respectively, and the calibration curve (y=1.5171x-1.007) exhibited good linearity within a defined range (r 2 =0.907). These results indicate that the combination of column-switching HPLC and ECD is a powerful tool for the specific, reliable detection of 3-HPMA in urine. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Analyte quantification with comprehensive two-dimensional gas chromatography: assessment of methods for baseline correction, peak delineation, and matrix effect elimination for real samples.

    PubMed

    Samanipour, Saer; Dimitriou-Christidis, Petros; Gros, Jonas; Grange, Aureline; Samuel Arey, J

    2015-01-02

    Comprehensive two-dimensional gas chromatography (GC×GC) is used widely to separate and measure organic chemicals in complex mixtures. However, approaches to quantify analytes in real, complex samples have not been critically assessed. We quantified 7 PAHs in a certified diesel fuel using GC×GC coupled to flame ionization detector (FID), and we quantified 11 target chlorinated hydrocarbons in a lake water extract using GC×GC with electron capture detector (μECD), further confirmed qualitatively by GC×GC with electron capture negative chemical ionization time-of-flight mass spectrometer (ENCI-TOFMS). Target analyte peak volumes were determined using several existing baseline correction algorithms and peak delineation algorithms. Analyte quantifications were conducted using external standards and also using standard additions, enabling us to diagnose matrix effects. We then applied several chemometric tests to these data. We find that the choice of baseline correction algorithm and peak delineation algorithm strongly influence the reproducibility of analyte signal, error of the calibration offset, proportionality of integrated signal response, and accuracy of quantifications. Additionally, the choice of baseline correction and the peak delineation algorithm are essential for correctly discriminating analyte signal from unresolved complex mixture signal, and this is the chief consideration for controlling matrix effects during quantification. The diagnostic approaches presented here provide guidance for analyte quantification using GC×GC. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  16. Determination of acetanilide herbicides in cereal crops using accelerated solvent extraction, solid-phase extraction and gas chromatography-electron capture detector.

    PubMed

    Zhang, Yaping; Yang, Jun; Shi, Ronghua; Su, Qingde; Yao, Li; Li, Panpan

    2011-07-01

    A method was developed to determine eight acetanilide herbicides from cereal crops based on accelerated solvent extraction (ASE) and solid-phase extraction (SPE) followed by gas chromatography-electron capture detector (GC-ECD) analysis. During the ASE process, the effect of four parameters (temperature, static time, static cycles and solvent) on the extraction efficiency was considered and compared with shake-flask extraction method. After extraction with ASE, four SPE tubes (graphitic carbon black/primary secondary amine (GCB/PSA), GCB, Florisil and alumina-N) were assayed for comparison to obtain the best clean-up efficiency. The results show that GCB/PSA cartridge gave the best recoveries and cleanest chromatograms. The analytical process was validated by the analysis of spiked blank samples. Performance characteristics such as linearity, limit of detection (LOD), limit of quantitation (LOQ), precision and recovery were studied. At 0.05 mg/kg spiked level, recoveries and precision values for rice, wheat and maize were 82.3-115.8 and 1.1-13.6%, respectively. For all the herbicides, LOD and LOQ ranged from 0.8 to 1.7 μg/kg and from 2.4 to 5.3 μg/kg, respectively. The proposed analytical methodology was applied for the analysis of the targets in samples; only three herbicides, propyzamid, metolachlor and diflufenican, were detected in two samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Contaminant Mass Transfer During Boiling in Fractured Geologic Media

    DTIC Science & Technology

    2011-04-01

    on GC-ECD. Bromide was measured on a Dionex AS50 ion chromatography system equipped with a CD25 conductivity detector and a Dionex guard column...EDB Dibromethane EPICS Equilibrium Partitioning In Closed Systems FID Flame Ionized Detector GC Gas Chromatography IC Ion Chromatography ...International). Bromide was measured from filtered samples with a Dionex ion chromatograph (IC) with an AS11/AG11 column. The eluant for bromide

  18. Determination of the location of positive charges in gas-phase polypeptide polycations by tandem mass spectrometry

    NASA Astrophysics Data System (ADS)

    Kjeldsen, Frank; Savitski, Mikhail M.; Adams, Christopher M.; Zubarev, Roman A.

    2006-06-01

    Location of protonated sites in electrospray-ionized gas-phase peptides and proteins was performed with tandem mass spectrometry using ion activation by both electron capture dissociation (ECD) and collisional activation dissociation (CAD). Charge-carrying sites were assigned based on the increment in the charge state of fragment ions compared to that of the previous fragment in the same series. The property of ECD to neutralize preferentially the least basic site was confirmed by the analysis of three thousand ECD mass spectra of doubly charged tryptic peptides. Multiply charged cations of bradykinin, neurotensin and melittin were studied in detail. For n+ precursors, ECD revealed the positions of (n - 1) most basic sites, while CAD could in principle locate alln charges. However, ECD introduced minimal proton mobilization and produced more conclusive data than CAD, for which N- and C-terminal data often disagreed. Consistent with the dominance of one charge conformer and its preservation in ECD, the average charge states of complementary fragments of n+ ions almost always added up to (n - 1)+, while the similar figure in CAD often deviated from n+, indicating extensive charge isomerization under collisional excitation. For bradykinin and neurotensin, the charge assignments were largely in agreement with the intrinsic gas-phase basicity of the respective amino acid residues. For melittin ions in higher charge states, ECD revealed the charging at both intrinsically basic as well as at less basic residues, which was attributed to charge sharing with other groups due to the presence of secondary and higher order structures in this larger polypeptide.

  19. The determination and role of peroxyacetil nitrate in photochemical processes in atmosphere

    PubMed Central

    2012-01-01

    Peroxyacetilnitrates (PAN) is the most characteristic photoxidant of a range of secondary pollutants formed by the photochemical reaction of hydrocarbons with nitrogen oxides in the atmosphere: it is phytotoxic and shows an increasing role in human health effects due to ambient air exposure, especially in presence of high ozone concentrations. Because of the similarity of the conditions required for their photochemical production PAN is observed in conjunction with elevated ozone concentrations. PAN has very low natural background concentrations so it is the very specific indicator of anthropogenic photochemical air pollution. In this paper we report PAN concentrations determined in Rome urban area during winter- and summer-period. PAN measurements were carried out by means of a gas-chromatograph equipped with an Electron Capture Detector (ECD) detector. For identifying the acute episodes of atmospheric photochemical pollutants the relationship between PAN and the variable Ox (=NO2+O3) which describes the oxidation process evolution is investigated. The role of Volatile Organic Compounds and PAN in the ozone formation is investigated as well the issue of taking in account the autovehicular emissions for checking the NOx fraction in fuel. PMID:22594443

  20. Chemical Tracers as an Indicator of Transport in the UT/LS

    NASA Astrophysics Data System (ADS)

    Moore, F. L.; Hurst, D. F.; Elkins, J. W.; Nance, J. D.; Dutton, G. S.; Hall, B. D.

    2009-12-01

    Previous airborne studies have proven the scientific value of chemical tracers in examining transport of the Upper Troposphere and Lower Stratosphere (UT/LS). ESRL scientists operated two airborne gas chromatographs on the NCAR G-V during the NSF sponsored Stratosphere-Troposphere Analyses of Regional Transport START-08 campaign over the midlatitudes of central North America. The Unmanned aircraft systems Chromatograph for Atmospheric Trace Species (UCATS) is comprised of a two-channel electron capture detection-gas chromatograph (ECD-GC), an ozone absorption photometer, and a water vapor tunable diode laser spectrometer. It measures N2O and SF6 every 70 seconds on one EC-GC channel, and H2, CO, and CH4 every 140 seconds on the second channel. PAN and Trace Hydrohalocarbon ExpeRiment (PANTHER) is a six-channel gas chromatograph with four ECD-GC channels and two mass selective detector-gas chromatograph (MSD-GC) channels that double the sampling rate to 180 seconds by using two traps and columns. The ECD-GC channels measure N2O, SF6, CFC-11, CFC-12, halon-1211, and PAN once every 70 seconds, H2, CH4, and CO once every 140 seconds. The two MSD-GC channels measure methyl halides (CH3I, CH3Cl, CH3I), HCFCs (22, 141b, 142b), HFC-134a, sulfur gases (COS and CS2) once every 180 seconds. These data represent a diversity of atmospheric lifetimes and are useful in examining transport in UT/LS. One example is the tracer-tracer correlation plot of N2O versus SF6, which shows three distinction regions of transport, LS, tropospause transition, and UT. Tropospheric gradients for both gases are apparent in the UT region. Other correlations will be shown in this presentation. A comparison of common species measured between UCATS and PANTHER shows a better than one percent agreement between the two instruments.

  1. [In-situ measurement of background atmospheric HCFC-142b using GC-MS and GC-ECD method].

    PubMed

    Guo, Li-feng; Yao, Bo; Zhou, Ling-xi; Li, Pei-chang; Xu, Lin

    2013-05-01

    Custom-made GC-MS and GC-ECD in-situ measurement systems were established at the Shangdianzi GAW Regional station. From May 2010 to May 2011, the precisions for GC-MS and GC-ECD systems were 0.23% and 0.88%, respectively, and the HCFC-142b mole fraction during the observation period ranged from 21 x 10(-12) to 355 x 10(-12). The result of the independent-sample T test was P > 0.05, and there was no significant difference in HCFC-142b mole fraction measured by the two systems. The small difference of HCFC-142b mole fraction measured by GC-MS and GC-ECD might be associated with the different sampling time and precision of the two systems. A statistical filter of "robust local regression" was applied to separate HCFC-142b background and pollution data. The mean difference, median difference, 25 and 75 percent difference of background data measured by GC-MS and GC-ECD were all within the precisions. The pollution events captured by the two systems showed similar characters. Results from both systems showed a higher HCFC-142b level in summer and autumn than in winter. The pollution mole fraction of the two systems showed similar seasonal changes.

  2. Rabbit antithymocyte globulin is more beneficial in standard kidney than in extended donor recipients.

    PubMed

    Hardinger, Karen L; Brennan, Daniel C; Schnitzler, Mark A

    2009-05-15

    In a randomized, international study comparing rabbit antithymocyte globulin (TMG) and basiliximab (BAS) induction in renal transplant recipients at risk for delayed graft function or acute rejection (n=278), TMG was associated with less acute rejection at 1 year. This study analyzed outcomes stratified by standard criteria donor (SCD), extended criteria donor (ECD), and hypertensive donor. Data-capture limitations necessitated defining ECD as donor age more than 60 years or 50 to 60 years with hypertension and renal insufficiency. Seventy-five recipients received ECD-kidneys (28.4% TMG vs. 25.6% BAS, P=NS) and 203 recipients received SCD-kidneys (72.6% TMG vs. 74.4% BAS, P=NS). Recipients of an ECD or hypertensive donor-kidney had similar outcomes between treatment groups. Recipients of an SCD-kidney treated with TMG had less rejection (odds ratio [OR] 0.48). Recipients of a normotensive donor-kidney treated with TMG had less rejection (OR 0.56). Recipients of a normotensive, SCD-kidney treated with TMG had less rejection (OR 0.47) and death (OR 0.17) than their counterparts treated with BAS. Contrary to its perceived niche in recipients of ECD-kidneys, TMG was most beneficial in patients who received a normotensive, deceased SCD kidney.

  3. Multi-residue analysis of 26 organochlorine pesticides in Alpinia oxyphylla by GC-ECD after solid phase extraction and acid cleanup.

    PubMed

    Zhao, Xiangsheng; Zhou, Yakui; Kong, Weijun; Gong, Bao; Chen, Deli; Wei, Jianhe; Yang, Meihua

    2016-04-01

    A simple and effective multi-residue method was developed and validated for the analysis of 26 organochlorine pesticide residues in Alpinia oxyphylla by a gas chromatography with an electron capture detector (GC-ECD). The target pesticides were extracted by sonication and cleaned up with florisil solid phase extraction and sulphuric acid. Some crucial parameters, including extraction solvent and time, sorbent type, elute solvent and concentration of sulphuric acid were optimized to improve the performance of sample preparation procedure. The optimized method gave high sensitivity with detection limit ranging from 0.1 to 2.0μg/kg. Matrix-matched calibration was employed for the quantification, and a wide linear range (from 1.0 to 1000μg/kg) with r(2) values ranging from 0.9971 to 0.9998 was obtained. For the majority of the tested pesticides, the average recoveries were in acceptable range (between 70% and 110%) with relative standard deviation values below 15.0%. Matrix effect was evaluated for target compounds through the study of ratio of peak area obtained in the solvent and blank matrix. The proposed method was applied to simultaneously analyze 26 pesticides in 55 batches of Alpinia oxyphylla samples. 3 samples were found to be positive with four pesticides (α-BHC, quintozene, trans-chlordane and op'-DDD), which were confirmed by gas chromatography-mass spectrometry (GC-MS) in selective ion monitoring (SIM) mode. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Modeling the Complexities of Water, Hygiene, and Health in Limpopo Province, South Africa

    PubMed Central

    Mellor, Jonathan E.; Smith, James A.; Learmonth, Gerard P.; Netshandama, Vhonani O.; Dillingham, Rebecca A.

    2013-01-01

    Researchers have long studied the causes and prevention strategies of poor household water quality and early childhood diarrhea using intervention-control trials. Although the results of such trails can lead to useful information, they do not capture the complexity of this natural/engineered/social system. We report on the development of an agent-based model (ABM) to study such a system in Limpopo, South Africa. The study is based on four years of field data collection to accurately capture essential elements of the communities and their water contamination chain. An extensive analysis of those elements explored behaviors including water collection and treatment frequency as well as biofilm buildup in water storage containers, source water quality, and water container types. Results indicate that interventions must be optimally implemented in order to see significant reductions in early childhood diarrhea (ECD). Household boiling frequency, source water quality, water container type and the biofilm layer contribution were deemed to have significant impacts on ECD. Furthermore, concurrently implemented highly effective interventions were shown to reduce diarrhea rates to very low levels even when other, less important practices were sub-optimal. This technique can be used by a variety of stakeholders when designing interventions to reduce ECD incidences in similar settings. PMID:23186073

  5. Modeling the complexities of water, hygiene, and health in Limpopo Province, South Africa.

    PubMed

    Mellor, Jonathan E; Smith, James A; Learmonth, Gerard P; Netshandama, Vhonani O; Dillingham, Rebecca A

    2012-12-18

    Researchers have long studied the causes and prevention strategies of poor household water quality and early childhood diarrhea using intervention-control trials. Although the results of such trails can lead to useful information, they do not capture the complexity of this natural/engineered/social system. We report on the development of an agent-based model (ABM) to study such a system in Limpopo, South Africa. The study is based on four years of field data collection to accurately capture essential elements of the communities and their water contamination chain. An extensive analysis of those elements explored behaviors including water collection and treatment frequency as well as biofilm buildup in water storage containers, source water quality, and water container types. Results indicate that interventions must be optimally implemented in order to see significant reductions in early childhood diarrhea (ECD). Household boiling frequency, source water quality, water container type, and the biofilm layer contribution were deemed to have significant impacts on ECD. Furthermore, concurrently implemented highly effective interventions were shown to reduce diarrhea rates to very low levels even when other, less important practices were suboptimal. This technique can be used by a variety of stakeholders when designing interventions to reduce ECD incidences in similar settings.

  6. Optimizations of packed sorbent and inlet temperature for large volume-direct aqueous injection-gas chromatography to determine high boiling volatile organic compounds in water.

    PubMed

    Yu, Bofan; Song, Yonghui; Han, Lu; Yu, Huibin; Liu, Yang; Liu, Hongliang

    2014-08-22

    For the expanded application area, fast trace analysis of certain high boiling point (i.e., 150-250 °C) volatile organic compounds (HVOCs) in water, a large volume-direct aqueous injection-gas chromatography (LV-DAI-GC) method was optimized for the following parameters: packed sorbent for sample on-line pretreatment, inlet temperature and detectors configuration. Using the composite packed sorbent self-prepared with lithium chloride and a type of diatomite, the method enabled safe injection of an approximately 50-100 μL sample at an inlet temperature of 150 °C in the splitless mode and separated HVOCs from water matrix in 2 min. Coupled with a flame ionization detector (FID), an electron capture detector (ECD) and a flame photometric detector (FPD), the method could simultaneously quantify 27 HVOCs that belong to seven subclasses (i.e., halogenated aliphatic hydrocarbons, chlorobenzenes, nitrobenzenes, anilines, phenols, polycyclic aromatic hydrocarbons and organic sulfides) in 26 min. Injecting a 50 μL sample without any enrichment step, such as cryotrap focusing, the limits of quantification (LOQs) for the 27 HVOCs was 0.01-3 μg/L. Replicate analyses of the 27 HVOCs spiked source and river water samples exhibited good precision (relative standard deviations ≤ 11.3%) and accuracy (relative errors ≤ 17.6%). The optimized LV-DAI-GC was robust and applicable for fast determination and automated continuous monitoring of HVOCs in surface water. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. The Competitive Influence of Li+, Na+, K+, Ag+, and H+ on the Fragmentation of a PEGylated Polymeric Excipient

    NASA Astrophysics Data System (ADS)

    Wei, Juan; Bristow, Anthony W. T.; O'Connor, Peter B.

    2015-01-01

    The collisionally activated dissociation (CAD) and electron capture dissociation (ECD) of doubly charged tocopheryl polyethylene glycol succinate (TPGS) have been examined. Li+, Na+, K+, Ag+, and H+ were selected in the study, and the competitive influence of each ion was investigated by fragmenting TPGS attached with two different cations, [M + X1 + X2]2+ (X1 and X2 refer to Li+, Na+, K+, Ag+, H+). For metallic adducts, CAD results show that the dissociation of ionic adducts from the precursor is most likely depending on the binding strength, where the affinity of each ion to the TPGS is in the order of Ag+ ≈ Li+ ˃ Na+ ˃ K+. Introducing more strongly bound adducts increases fragmentation. During ECD, however, the silver cation is lost most easily compared with the other alkali metal ions, but silver also shows a dominant role in producing fragmentations. Moreover, the charge carriers are lost in an order (Ag+ ˃ Na+ ˃ K+ ≥ Li+ where the loss of Ag is most easily) that appears to correlate with the standard reduction potential of the metallic ions (Ag+ ˃ Na+ ˃ K+ ˃ Li+). The ECD results suggest that the reduction potential of the charge carrier could be an important factor influencing the fragmentation, where the ion with a high reduction potential is more effective in capturing electrons, but may also be lost easily before leading to any fragmentation. Finally, a proton has the weakest binding with the TPGS according to the CAD results, and its dissociation in ECD follows the order of the reduction potential (Ag+ ˃ H+ ˃ Na+ ˃ K+ > Li+).

  8. Composition and stability of phytochemicals in five varieties of black soybeans (glycine max)

    USDA-ARS?s Scientific Manuscript database

    Phytochemical compositions of five varieties of black soybeans (Glycine max) and their stabilities at room temperature, 4 deg.C and -80 deg.C over 14 months were determined by HPLC systems with electrochemical (HPLC-ECD) and UV detectors. Polyphenol profiling was carried out by liquid chromatography...

  9. [Influence of organochlorine pesticides in wastewater on the soil along the channel].

    PubMed

    Xu, Liang; Zhang, Cai-Xiang; Liu, Min; Liao, Xiao-Ping; Yao, Lin-Lin; Li, Jia-Le; Xiang, Qing-Qing

    2013-08-01

    Nine profile soil samples and two sewage water samples were collected from Xiaodian sewage irrigation area in Taiyuan city, concentrations of organochlorine pesticides (OCPs) were determined by the gas chromatography coupled with electron capture detector (GC-ECD) to analyze the influence of the leakage of sewage water. The result shows that OCPs in sewage water were mainly composed of HCHs. Concentrations of DDTs and other organochlorine pesticides were very low or out of the detection limit. Concentrations of sigmaOCPs and HCHs in eight profiles near irrigation channels to some extend decreased with the increasing of the linear distance off the channel, which shows influences of the leakage of sewage water on the soil nearby. Concentrations of HCHs clearly decreased with the increasing of soil depth in most profile soils. For the horizontal direction, concentrations of HCHs also decreased with the increasing of the linear distance off the channel. The correlation between HCHs and TOC was positive, but no correlation between pH and HCHs was found.

  10. Organochlorine pesticide distribution in an organic production system for cow's milk in Chiapas, Mexico.

    PubMed

    Murga, María N; Gutiérrez, Rey; Vega, Salvador; Pérez, José J; Ortiz, Rutilio; Schettino, Beatriz; Yamasaki, Alberto; Ruíz, Jorge L

    2016-09-01

    The objective of this study was to evaluate the presence of organochlorine pesticides in samples of forage, soil, water, and milk in four units of an organic production system for cow´s milk (samples of forage, milk, soil, and water) in Tecpatan, Chiapas, Mexico. The organochlorine pesticides were extracted from forage, soil and water based on the USEPA (2005) guideline and from milk based on the IDF 1991 guideline. The pesticides were identified and quantified by gas chromatography with electron capture detector (CG-ECD). In general, the highest average concentration of total pesticides was found in the samples of milk and forage (311 ± 328 and 116.5 ±77 ng g(-1) respectively). Although, the production systems analyzed are organic, organochlorine pesticides were detected in all environmental samples (forage, soil, water, and organic milk). Although no values surpassed the defined limits of Mexican and International regulation it is advisable that a monitoring program of contaminants in these production systems is continued.

  11. Disinfection Byproducts in Drinking Water and Evaluation of Potential Health Risks of Long-Term Exposure in Nigeria.

    PubMed

    Benson, Nsikak U; Akintokun, Oyeronke A; Adedapo, Adebusayo E

    2017-01-01

    Levels of trihalomethanes (THMs) in drinking water from water treatment plants (WTPs) in Nigeria were studied using a gas chromatograph (GC Agilent 7890A with autosampler Agilent 7683B) equipped with electron capture detector (ECD). The mean concentrations of the trihalomethanes ranged from zero in raw water samples to 950  μ g/L in treated water samples. Average concentration values of THMs in primary and secondary disinfection samples exceeded the standard maximum contaminant levels. Results for the average THMs concentrations followed the order TCM > BDCM > DBCM > TBM. EPA-developed models were adopted for the estimation of chronic daily intakes (CDI) and excess cancer incidence through ingestion pathway. Higher average intake was observed in adults (4.52 × 10 -2  mg/kg-day), while the ingestion in children (3.99 × 10 -2  mg/kg-day) showed comparable values. The total lifetime cancer incidence rate was relatively higher in adults than children with median values 244 and 199 times the negligible risk level.

  12. Development, validation and matrix effect of a QuEChERS method for the analysis of organochlorine pesticides in fish tissue.

    PubMed

    Stremel, Tatiana R De O; Domingues, Cinthia E; Zittel, Rosimara; Silva, Cleber P; Weinert, Patricia L; Monteiro, Franciele C; Campos, Sandro X

    2018-04-03

    This study aims to develop and validate a method to determine OCPs in fish tissues, minimizing the consumption of sample and reagents, by using a modified QuEChERS along with ultrasound, d-SPE and gas chromatography with an electron capture detector (GC-ECD), refraining the pooling. Different factorial designs were employed to optimize the sample preparation phase. The validation method presented a recovery of around 77.3% and 110.8%, with RSD lower than 13% and the detection limits were between 0.24 and 2.88 μgkg -1 , revealing good sensitiveness and accuracy. The method was satisfactorily applied to the analysis of tissues from different species of fish and OCPs residues were detected. The proposed method was shown effective to determine OCPs low concentrations in fish tissues, using small sample mass (0.5 g), making the sample analyses viable without the need for grouping (pool).

  13. Dissipation and residue of myclobutanil in lychee.

    PubMed

    Liu, Yanping; Sun, Haibin; Liu, Fengmao; Wang, Siwei

    2012-06-01

    The dissipation and residue of myclobutanil in lychee under field conditions were studied. To determine myclobutanil residue in samples, an analytical method with a florisil column clean-up and detected by gas chromatography-electron capture detector (GC-ECD) was developed. Recoveries were found in the range of 83.24 %-89.00 % with relative standard deviations of 2.67 %-9.88 %. This method was successfully applied to analyze the dissipation and residue of myclobutanil in lychee in Guangdong and Guangxi Province, China. The half lives in lychee were from 2.2 to 3.4 days. The residues of myclobutanil in lychee flesh were all below the limit of quantification (LOQ) value (0.01 mg/kg), and most of the residues were concentrated in the peel. The terminal residues of myclobutanil were all bellow the maximum residue limit (MRL) value set by European Union (EU) (0.02 mg/kg). Hence it was safe for the use of this pesticide and the results also could give a reference for MRL setting of myclobutanil in lychee in China.

  14. Methyl bromide determination in selected foods by headspace technique.

    PubMed

    Daft, J L

    1993-01-01

    A headspace method used earlier for determining methyl bromide (MB) in assorted nuts and peanut butters has been successfully applied to other foods that could potentially contain traces of this toxic fumigant. The foods tested include 63 off-the-shelf spices and seasonings, 83 table-ready items (grain-based, dried, or highly seasoned), 30 dried fruits and trail mixes, and 38 oil-based items (oil-seeds, cooking oils, or spicy oil-based dressings). Sample headspace gas is produced by blending < or = 50 g sample in 250 +/- 50 mL aqueous solution in a sealed 1000 mL blender cup. After equilibration at 25 degrees C, the headspace is sampled with a gas-tight syringe and injected into a dual column-dual detector gas chromatograph. One determination is made with a 20% OV-101 packed column and a 63Ni electron capture detector (ECD), the other with a GS-Q wide-bore capillary column and a Hall electrolytic conductivity detector (HECD). Of the approximately 200 samples tested, none contained detectable MB residue at a quantitation limit < 100 ng/g sample. All fortified samples yielded MB recovery. Samples were fortified at levels ranging from 78 to 3250 ng MB/g. Recoveries ranged from a mean high of 56% for spices and seasonings to a mean low of 30% for oil-based foods. The overall recovery and CV, including the results from assorted nuts and peanut butters, were 46 and 33%, respectively.

  15. AVOIDING PITFALLS IN THE DETERMINATION OF HALOCARBOXYLIC ACIDS: THE PHOTOCHEMISTRY OF METHYLATION

    EPA Science Inventory

    Haloethanoic (haloacetic) acids are formed during chlorination of drinking water and are regulated by the Environmental Protection Agency (EPA). These compounds are normally quantified by gas chromatography with electron capture detection (GC-ECD) ad the methyl esters. EPA Meth...

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Jiang; Malmirchegini, G. Reza; Clubb, Robert T.

    Native mass spectrometry (MS) has become an invaluable tool for the characterization of proteins and non-covalent protein complexes under near physiological solution conditions. Here we report the structural characterization of human hemoglobin (Hb), a 64 kDa oxygen-transporting protein complex, by high resolution native top-down mass spectrometry using electrospray ionization (ESI) and a 15-Tesla Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. Native MS preserves the non-covalent interactions between the globin subunits, and electron capture dissociation (ECD) produces fragments directly from the intact Hb complex without dissociating the subunits. Using activated ion ECD, we observe the gradual unfolding process of themore » Hb complex in the gas phase. Without protein ion activation, the native Hb shows very limited ECD fragmentation from the N-termini, suggesting a tightly packed structure of the native complex and therefore low fragmentation efficiency. Precursor ion activation allows steady increase of N-terminal fragment ions, while the C-terminal fragments remain limited (38 c ions and 4 z ions on the α chain; 36 c ions and 2 z ions on the β chain). This ECD fragmentation pattern suggests that upon activation, the Hb complex starts to unfold from the N-termini of both subunits, whereas the C-terminal regions and therefore the potential regions involved in the subunit binding interactions remain intact. ECD-MS of the Hb dimer show similar fragmentation patterns as the Hb tetramer, providing further evidence for the hypothesized unfolding process of the Hb complex in the gas phase. Native top-down ECD-MS allows efficient probing of the Hb complex structure and the subunit binding interactions in the gas phase. Finally, it may provide a fast and effective means to probe the structure of novel protein complexes that are intractable to traditional structural characterization tools.« less

  17. Structural Heterogeneity of Doubly-Charged Peptide b-Ions

    NASA Astrophysics Data System (ADS)

    Li, Xiaojuan; Huang, Yiqun; O'Connor, Peter B.; Lin, Cheng

    2011-02-01

    Performing collisionally activated dissociation (CAD) and electron capture dissociation (ECD) in tandem has shown great promise in providing comprehensive sequence information that was otherwise unobtainable by using either fragmentation method alone or in duet. However, the general applicability of this MS3 approach in peptide sequencing may be undermined by the formation of non-direct sequence ions, as sometimes observed under CAD, particularly when multiple stages of CAD are involved. In this study, varied-sized doubly-charged b-ions from three tachykinin peptides were investigated by ECD. Sequence scrambling was observed in ECD of all b-ions from neurokinin A (HKTDSFVGLM-NH2), suggesting the presence of N- and C-termini linked macro-cyclic conformers. On the contrary, none of the b-ions from eledoisin (pEPSKDAFIGLM-NH2) produced non-direct sequence ions under ECD, as it does not contain a free N-terminal amino group. ECD of several b-ions from Substance P (RPKPQQFFGLM-NH2) showed series of cm-Lys fragment ions which suggested that the macro-cyclic structure may also be formed by connecting the C-terminal carbonyl group and the ɛ-amino group of the lysine side chain. Theoretical investigation of selected Substance P b-ions revealed several low energy conformers, including both linear oxazolones and macro-ring structures, in corroboration with the experimental observation. This study showed that a b-ion may exist as a mixture of several forms, with their propensities influenced by its N-terminus, length, and certain side-chain groups. Further, the presence of several macro-cyclic structures may result in erroneous sequence assignment when the combined CAD and ECD methods are used in peptide sequencing.

  18. Structural Heterogeneity of Doubly-Charged Peptide b-Ions

    PubMed Central

    Li, Xiaojuan; Huang, Yiqun; O’Connor, Peter B.; Lin, Cheng

    2011-01-01

    Performing collisionally activated dissociation (CAD) and electron capture dissociation (ECD) in tandem has shown great promise in providing comprehensive sequence information that was otherwise unobtainable by using either fragmentation method alone or in duet. However, the general applicability of this MS3 approach in peptide sequencing may be undermined by the formation of non-direct sequence ions, as sometimes observed under CAD, particularly when multiple stages of CAD are involved. In this study, varied-sized doubly-charged b-ions from three tachykinin peptides were investigated by ECD. Sequence scrambling was observed in ECD of all b-ions from neurokinin A (HKTDSFVGLM-NH2), suggesting the presence of N- and C-termini linked macro-cyclic conformers. On the contrary, none of the b-ions from eledoisin (pEPSKDAFIGLM-NH2) produced non-direct sequence ions under ECD, as it does not contain a free N-terminal amino group. ECD of several b-ions from Substance P (RPKPQQFFGLM-NH2) showed series of cm-Lys fragment ions which suggested that the macro-cyclic structure may also be formed by connecting the C-terminal carbonyl group and the ε-amino group of the lysine side chain. Theoretical investigation of selected Substance P b-ions revealed several low energy conformers, including both linear oxazolones and macro-ring structures, in corroboration with the experimental observation. This study showed that a b-ion may exist as a mixture of several forms, with their propensities influenced by its N-terminus, length, and certain side-chain groups. Further, the presence of several macro-cyclic structures may result in erroneous sequence assignment when the combined CAD and ECD methods are used in peptide sequencing. PMID:21472584

  19. 75 FR 26662 - Fluazinam; Pesticide Tolerances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-12

    ... due to systemic toxicity and not a result of frank neurotoxicity. No signs of neurotoxicity were... chromatography with electron capture detection (GC/ECD), is available to enforce the tolerance expression for...) enforcement method is also available to enforce the tolerance expression for wine grapes, which includes...

  20. Determination of PCBs in fish using enzyme-linked immunosorbent assay (ELISA)

    USGS Publications Warehouse

    Lasrado, J.A.; Santerre, C.R.; Zajicek, J.L.; Stahl, J.R.; Tillitt, D.E.; Deardorff, D.

    2003-01-01

    Polychlorinated biphenyls (PCBs) were determined in fish tissue using an enzyme-linked immunosorbent assay (ELISA). Standard curves for Aroclor 1248, 1254, and 1260 in catfish tissue were developed with ranges from 0.05 to 0.5 ppm and 0.5 to 5.0 ppm. Wild fish were initially analyzed using gas chromatography/electron-capture detection (GC/ECD) and those having residues within the standard curve ranges were analyzed with ELISA. Results obtained using ELISA and GC/ECD were not significantly different (p < 0.05) from 0.05 to 0.5 ppm. From 0.5 to 5.0 ppm, the standard curve for Aroclor 1254 was the best predictor of total PCB in wild fish samples.

  1. A SIMPLE AND FAST EXTRACTION METHOD FOR ORGANOCHLORINE PESTICIDES AND POLYCHLORINATED BIPHENYLS IN SMALL VOLUMES OF AVIAN SERUM

    EPA Science Inventory

    A solid-phase extraction (SPE) method was developed using 8 M urea to desorb and extract organochlorine pesticides (OCs) and polychlorinated biphenyls (PCBs) from avian serum for analysis by capillary gas chromatography with electron capture detection (GC-ECD). The analytes were ...

  2. ANALYSIS OF SOIL AND DUST SAMPLES FOR POLYCHLORINATED BIPHENYLS BY ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA)

    EPA Science Inventory

    An inhibition enzyme-linked immunosorbent assay (ELISA) was used to determine polychlorinated biphenyls (PCBs) in house dust and soil. Soil and house dust samples were analyzed for PCB by both gas chromatography/electron capture detection (GC/ECD) and ELISA methods. A correlati...

  3. Electronic Circular Dichroism of [16]Helicene With Simplified TD-DFT: Beyond the Single Structure Approach.

    PubMed

    Bannwarth, Christoph; Seibert, Jakob; Grimme, Stefan

    2016-05-01

    The electronic circular dichroism (ECD) spectrum of the recently synthesized [16]helicene and a derivative comprising two triisopropylsilyloxy protection groups was computed by means of the very efficient simplified time-dependent density functional theory (sTD-DFT) approach. Different from many previous ECD studies of helicenes, nonequilibrium structure effects were accounted for by computing ECD spectra on "snapshots" obtained from a molecular dynamics (MD) simulation including solvent molecules. The trajectories are based on a molecule specific classical potential as obtained from the recently developed quantum chemically derived force field (QMDFF) scheme. The reduced computational cost in the MD simulation due to the use of the QMDFF (compared to ab-initio MD) as well as the sTD-DFT approach make realistic spectral simulations feasible for these compounds that comprise more than 100 atoms. While the ECD spectra of [16]helicene and its derivative computed vertically on the respective gas phase, equilibrium geometries show noticeable differences, these are "washed" out when nonequilibrium structures are taken into account. The computed spectra with two recommended density functionals (ωB97X and BHLYP) and extended basis sets compare very well with the experimental one. In addition we provide an estimate for the missing absolute intensities of the latter. The approach presented here could also be used in future studies to capture nonequilibrium effects, but also to systematically average ECD spectra over different conformations in more flexible molecules. Chirality 28:365-369, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  4. Investigation of the Mechanism of Electron Capture and Electron Transfer Dissociation of Peptides with a Covalently Attached Free Radical Hydrogen Atom Scavenger.

    PubMed

    Sohn, Chang Ho; Yin, Sheng; Peng, Ivory; Loo, Joseph A; Beauchamp, J L

    2015-11-15

    The mechanisms of electron capture and electron transfer dissociation (ECD and ETD) are investigated by covalently attaching a free-radical hydrogen atom scavenger to a peptide. The 2,2,6,6-tetramethylpiperidin-l-oxyl (TEMPO) radical was chosen as the scavenger due to its high hydrogen atom affinity (ca. 280 kJ/mol) and low electron affinity (ca. 0.45 ev), and was derivatized to the model peptide, FQX TEMPO EEQQQTEDELQDK. The X TEMPO residue represents a cysteinyl residue derivatized with an acetamido-TEMPO group. The acetamide group without TEMPO was also examined as a control. The gas phase proton affinity (882 kJ/mol) of TEMPO is similar to backbone amide carbonyls (889 kJ/mol), minimizing perturbation to internal solvation and sites of protonation of the derivatized peptides. Collision induced dissociation (CID) of the TEMPO tagged peptide dication generated stable odd-electron b and y type ions without indication of any TEMPO radical induced fragmentation initiated by hydrogen abstraction. The type and abundance of fragment ions observed in the CID spectra of the TEMPO and acetamide tagged peptides are very similar. However, ECD of the TEMPO labeled peptide dication yielded no backbone cleavage. We propose that a labile hydrogen atom in the charge reduced radical ions is scavenged by the TEMPO radical moiety, resulting in inhibition of N-C α backbone cleavage processes. Supplemental activation after electron attachment (ETcaD) and CID of the charge-reduced precursor ion generated by electron transfer of the TEMPO tagged peptide dication produced a series of b + H (b H ) and y + H (y H ) ions along with some c ions having suppressed intensities, consistent with stable O-H bond formation at the TEMPO group. In summary, the results indicate that ECD and ETD backbone cleavage processes are inhibited by scavenging of a labile hydrogen atom by the localized TEMPO radical moiety. This observation supports the conjecture that ECD and ETD processes involve long-lived intermediates formed by electron capture/transfer in which a labile hydrogen atom is present and plays a key role with low energy processes leading to c and z ion formation. Ab initio and density functional calculations are performed to support our conclusion, which depends most importantly on the proton affinity, electron affinity and hydrogen atom affinity of the TEMPO moiety.

  5. Validation of a multi-residue method to determine deltamethrin and alpha-cypermethrin in mosquito nets by gas chromatography with electron capture detection (GC-μECD)

    PubMed Central

    2013-01-01

    Background Nowadays long-lasting insecticidal mosquito nets (LNs) are frequently used around the world to protect people against malaria vectors. As they contain insecticide, laboratory control is needed to check whether the content of the active ingredient follows the conditions of the manufacturer and also if the active ingredient is still present after some time of use. For this purpose, an analytical method had to be developed. The fact that LNs include a range of polymers for the yarn and use coated or incorporated technologies for the active ingredient, it is a challenge to find only one analytical method determining the active ingredient in LNs, which takes into account both impregnation technologies. Some methods are provided by international organizations but are limited by the determination of only one pesticide per method. The aim of this study was to optimize a short time extraction method for deltamethrin and alpha-cypermethrin from coated and incorporated mosquito nets and also to detect both insecticides in one analytical run, using gas chromatography with electron capture detection (GC-μECD). Methods Based on the literature, the most suitable solvent and the adequate extraction process for the insecticides used for net making were identified and adapted for the new multi-residue method. Results The validation data of the multi-residue method to determine deltamethrin and alpha-cypermethrin in mosquito nets by GC-μECD are given. Depending on the concentration of the active ingredient spiked on the nets, the mean recovery for alpha-cypermethrin ranged between 86% and 107% with a relative standard deviation below 3.5%. For deltamethrin it ranged between 90% and 108% with a relative standard deviation also below 3.5%. The limit of detection is 0.009 g.a.i/kg of net (0.3 mg a.i./m2 of net) both for alpha-cypermethrin and deltamethrin. Conclusions Data obtained are excellent. A 30 minutes reflux extraction method with xylene was developed to determine alpha-cypermethrin and deltamethrin in long-lasting insecticidal mosquito nets (LNs) by gas chromatography with electron capture detection (GC-μECD). The method can be easily extended to others pyrethroid used for mosquito net treatment. This paper also presents an overview of the studies dealing with pesticide determination in mosquito nets. PMID:23514225

  6. Solid-phase microextraction with temperature-programmed desorption for the analysis of iodination disinfection byproducts.

    PubMed

    Frazey, P A; Barkley, R M; Sievers, R E

    1998-02-01

    An analytical approach for the determination of chlorination and iodination disinfection byproducts based on solid-phase microextraction (SPME) was developed. Solid-phase microextraction presents a simple, rapid, sensitive, and solvent-free approach to sample preparation in which analytes in either air or water matrixes are extracted into the polymeric coating of an optical fiber. Analytes are subsequently thermally desorbed in the injection port of a gas chromatograph for separation, detection, and quantitation. Thermal degradation of iodoform was observed during desorption from a polyacrylate fiber in initial GC/MS and GC/ECD experiments. Experiments were designed to determine SPME conditions that would allow quantification without significant degradation of analytes. Isothermal and temperature-programmed thermal desorptions were evaluated for efficacy in transferring analytes with wide-ranging volatilities and thermal stabilities into chromatographic analysis columns. A temperature-programmed desorption (TPD) (120-200 degrees C at 5 degrees C/min with an on-column injection port or 150-200 degrees C at 25 degrees C/min with a split/splitless injection port) was able to efficiently remove analytes with wide-ranging volatilities without causing thermal degradation. The SPME-TPD method was linear over 2-3 orders of magnitude with an electron capture detector and detection limits were in the submicrogram per liter range. Precision and detection limits for selected trihalomethanes were comparable to those of EPA method 551. Extraction efficiencies were not affected by the presence of 10 mg/L soap, 15 mg/L sodium iodide, and 6000 mg/L sodium thiosulfate. The SPME-TPD technique was applied to the determination of iodination disinfection byproducts from individual precursor compounds using GC/MS and to the quantitation of iodoform at trace levels in a water recycle system using GC/ECD.

  7. Studies of pesticide residues in tomatoes and cucumbers from Kazakhstan and the associated health risks.

    PubMed

    Lozowicka, Bozena; Abzeitova, Elmira; Sagitov, Abai; Kaczynski, Piotr; Toleubayev, Kazbek; Li, Alina

    2015-10-01

    The aim of the present study was to assess the level of pesticide residues in vegetables in the Almaty Region of Kazakhstan and to determine the potential health risks associated with the exposures to these pesticides. A total of 82 samples of cucumbers and tomatoes from top agro-based market and greenhouses were analysed using a gas chromatography-micro electron capture detector/nitrogen-phosphorous detector (GC-μECD/NPD), a multiresidue method to analyse 184 different pesticide types. The results indicated that more than half of samples (59 %) contained 29 pesticides, in which 10 are not registered in Kazakhstan, ranging from 0.01 to 0.88 mg kg(-1), and 28 % contained pesticide residues above maximum residue levels (MRLs). The estimated daily intakes (EDIs) ranged from 0.01 % of the acceptable daily intake (ADI) for pyrimethanil to 12.05 % of the ADI for lambda-cyhalothrin. The most critical commodity is triazophos and flusilazole in tomatoes, contributing 70.8 and 42.5 % to the acute hazard index (aHI). The results provided important information on the current pesticide contamination status of two commonly consumed vegetables and pointed an urgent need to control the use of plant protection products applied, especially potentially persistent pesticides, such as endosulfan and dicofol. These results also show that the detected pesticides may be considered a public health problem.

  8. [Application of fingerprint chromatogram in quality assessment of apple cider].

    PubMed

    Xu, Kangzhen; Song, Jirong; Ren, Yinghui; Ma, Haixia; Huang, Jie; Du, Xiaodan

    2007-01-01

    Fingerprints of 14 apple cider samples from different manufacturers were studied using high performance liquid chromatography (HPLC) with an electrochemical detector (ECD). The analysis was carried out on a Zorbax SB-C18 column at 30 degrees C with 2% (v/v) methanol aqueous solution-4% (v/v) acetic acid aqueous solution as mobile phase at a flow rate of 0.8 mL/min. The electrochemical detector was set at 0.7 V. By calculating the relative retention times of certain peaks with chlorogenic acid as the reference standard, 8 common peaks in the samples were analyzed. Relative retention times for the common peaks of various samples were calculated, and the similarities of all the samples were figured out through each peak area with the vectorial angle cosine method and correlative coefficient method. The results indicated that apple cider products of the same manufacturer have good similarity, with the similarities greater than 92.7%. According to this experiment, effectual microcosmic information for apple cider analysis was gained through HPLC and ECD. Moreover, this test method will help the analysis and the control of product quality, the development of new products and the establishment of trade standard.

  9. Native top-down mass spectrometry for the structural characterization of human hemoglobin

    DOE PAGES

    Zhang, Jiang; Malmirchegini, G. Reza; Clubb, Robert T.; ...

    2015-06-09

    Native mass spectrometry (MS) has become an invaluable tool for the characterization of proteins and non-covalent protein complexes under near physiological solution conditions. Here we report the structural characterization of human hemoglobin (Hb), a 64 kDa oxygen-transporting protein complex, by high resolution native top-down mass spectrometry using electrospray ionization (ESI) and a 15-Tesla Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. Native MS preserves the non-covalent interactions between the globin subunits, and electron capture dissociation (ECD) produces fragments directly from the intact Hb complex without dissociating the subunits. Using activated ion ECD, we observe the gradual unfolding process of themore » Hb complex in the gas phase. Without protein ion activation, the native Hb shows very limited ECD fragmentation from the N-termini, suggesting a tightly packed structure of the native complex and therefore low fragmentation efficiency. Precursor ion activation allows steady increase of N-terminal fragment ions, while the C-terminal fragments remain limited (38 c ions and 4 z ions on the α chain; 36 c ions and 2 z ions on the β chain). This ECD fragmentation pattern suggests that upon activation, the Hb complex starts to unfold from the N-termini of both subunits, whereas the C-terminal regions and therefore the potential regions involved in the subunit binding interactions remain intact. ECD-MS of the Hb dimer show similar fragmentation patterns as the Hb tetramer, providing further evidence for the hypothesized unfolding process of the Hb complex in the gas phase. Native top-down ECD-MS allows efficient probing of the Hb complex structure and the subunit binding interactions in the gas phase. Finally, it may provide a fast and effective means to probe the structure of novel protein complexes that are intractable to traditional structural characterization tools.« less

  10. Toward a general mixed quantum/classical method for the calculation of the vibronic ECD of a flexible dye molecule with different stable conformers: Revisiting the case of 2,2,2-trifluoro-anthrylethanol.

    PubMed

    Cerezo, Javier; Aranda, Daniel; Avila Ferrer, Francisco J; Prampolini, Giacomo; Mazzeo, Giuseppe; Longhi, Giovanna; Abbate, Sergio; Santoro, Fabrizio

    2018-06-01

    We extend a recently proposed mixed quantum/classical method for computing the vibronic electronic circular dichroism (ECD) spectrum of molecules with different conformers, to cases where more than one hindered rotation is present. The method generalizes the standard procedure, based on the simple Boltzmann average of the vibronic spectra of the stable conformers, and includes the contribution of structures that sample all the accessible conformational space. It is applied to the simulation of the ECD spectrum of (S)-2,2,2-trifluoroanthrylethanol, a molecule with easily interconvertible conformers, whose spectrum exhibits a pattern of alternating positive and negative vibronic peaks. Results are in very good agreement with experiment and show that spectra averaged over all the sampled conformational space can deviate significantly from the simple average of the contributions of the stable conformers. The present mixed quantum/classical method is able to capture the effect of the nonlinear dependence of the rotatory strength on the molecular structure and of the anharmonic couplings among the modes responsible for molecular flexibility. Despite its computational cost, the procedure is still affordable and promises to be useful in all cases where the ECD shape arises from a subtle balance between vibronic effects and conformational variety. © 2018 Wiley Periodicals, Inc.

  11. Estimating rates of denitrification enzyme activity in wetland soils and direct simultaneous quantification of nitrogen and nitrous oxide by membrane inlet mass spectrometry

    EPA Science Inventory

    Denitrification enzyme activity (DEA) was measured in short-term (4 h) anaerobic assays using Membrane Inlet Mass Spectrometry (MIMS) and electron capture gas chromatography (GC-ECD). Using MIMS, modifications of the instrument and sample handling allowed for the simultaneous me...

  12. Determination of polychlorinated biphenyls in ocean water and bovine milk using crosslinked polymeric ionic liquid sorbent coatings by solid-phase microextraction.

    PubMed

    Joshi, Manishkumar D; Ho, Tien D; Cole, William T S; Anderson, Jared L

    2014-01-01

    Crosslinked polymeric ionic liquid (PIL)-based sorbent coatings were employed in the extraction of 21 polychlorinated biphenyls (PCBs) from ocean water and bovine milk using solid-phase microextraction (SPME). The extraction temperature, time, and concentration of sodium chloride added to the matrix were optimized in order to determine the best extraction conditions for the extraction of PCBs. The analytical performance of the crosslinked PIL-based SPME fibers was compared with a commercial 7 µm polydimethylsiloxane (PDMS) fiber using gas chromatography (GC) employing an electron capture detector (ECD) and mass spectrometric detection (MS). Higher sensitivities for PCBs were achieved using PIL-based fibers when compared to PDMS fiber due to the incorporation of benzyl moieties into the PIL structures. The limits of detection (LOD) for all PCBs were determined to be in the low ng L(-1) range using the three studied coatings. Recovery studies were performed for PCBs in ocean water and bovine milk to validate the applicability of the current SPME method. © 2013 Published by Elsevier B.V.

  13. Environmental assessment of an enhanced-oil-recovery steam generator equipped with a low-NOx burner. Volume 2. Data supplement. Final report, January 1984-January 1985

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Castaldini, C.; Waterland, L.R.; Lips, H.I.

    1986-02-01

    The report is a compendium of detailed test sampling and analysis data obtained in field tests of an enhanced-oil-recovery steam generator (EOR steamer) equipped with a MHI PM low-NOx crude oil burner. Test data reported include equipment calibration records, steamer operating data, and complete flue-gas emission results. Flue-gas emission measurements included continuous monitoring for criteria pollutants; onsite gas chromatography (GC) for volatile hydrocarbons (Cl-C6); Methods 5/8 sampling for particulate and SO/sub 2/ and SO/sub 3/ emissions; source assessment sampling system (SASS) for total organics in two boiling-point ranges (100 to 300 C and greater than or equal to 300 C),more » organic compound category information using infrared spectrometry (IR), and specific quantitation of the semivolatile organic priority pollutants using gas chromatography/mass spectrometry (GC/MS); Andersen impactor train measurements of emitted particle-size distribution; and N/sub 2/O emissions by gas chromatography/electron-capture detector (GC/ECD).« less

  14. [Determination of lambda-cyhalothrin residue tea and soil using gas chromatography].

    PubMed

    Chen, Linglong; Chen, Jiuxing; Ma, Ming; Chen, Lihua; Yang, Hui; Zhang, Guiqun

    2010-08-01

    A gas chromatographic (GC) method was established for the determination of lambda-cyhalothrin residue in tea and soil. Tea and soil samples were extracted with hexane, separated by capillary column and determined by gas chromatography-electron capture detector (GC-ECD). The average recoveries of lambda-cyhalothrin in tea and soil were 89.0% - 94.1% and 89.8% - 94.7%, respectively at the spiking levels of 0.02 to 2.00 mg/kg. The corresponding relative standard deviations (RSDs, n = 5) were 3.0% -4.9% and 2.5% -4.2%, respectively. The limit of detection (S/N = 3) was 0.002 mg/kg for lambda-cyhalothrin. The degradations of 2.5% lambda-cyhalothrin microemulsion in tea and soil in Changsha, Hunan were investigated and the degradation equations were Y = 3.199 6e(-0.339 4x) and Y = 0.122 4e(-0.103 6x) with the correlation coefficients of 0.995 6 and 0.924 7, respectively. The half-lives of lambda-cyhalothrin in tea and soil were 2.04 days and 6.69 days, respectively.

  15. Environmental assessment of a watertube boiler firing a coal-water slurry. Volume 2. Data supplement. Final report, January 1984-March 1985

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeRosier, R.; Waterland, L.R.

    1986-02-01

    This report is a compendium of detailed test sampling and analysis data obtained in field tests of a watertube industrial boiler burning a coal/water slurry (CWS). Test data reported include preliminary stack test data, boiler operating data, and complete flue-gas emission results. Flue-gas emission measurements included continuous monitoring for criteria pollutants; onsite gas chromatography (GC) for volatile hydrocarbons (Cl-C6); Methods 5/8 sampling for particulate, SO/sub 2/, and SO/sub 3/ emissions; source assessment sampling system (SASS) for total organics in two boiling point ranges (100 to 300 C and > 300 C), organic compound category information using infrared spectrometry (IR), liquidmore » column (LC) chromatography separation, and low-resolution mass spectrometry (LRMS), specific quantitation of the semivolatile organic priority pollutants using gas chromatography/mass spectrometry (GC/MS), and trace-element emissions using spark-source mass spectrometry (SSMS) and atomic absorption spectroscopy (AAS); N/sub 2/O emissions by gas chromatography/electron-capture detector (GC/ECD); and biological assay testing of SASS and ash-stream samples.« less

  16. Migration and Accumulation of Octachlorodipropyl Ether in Soil-Tea Systems in Young and Old Tea Gardens.

    PubMed

    Liao, Min; Shi, Yan-Hong; Cao, Hai-Qun; Fang, Qing-Kui; Xiao, Jin-Jing; Hua, Ri-Mao

    2017-09-08

    The migration and accumulation of octachlorodipropyl ether (OCDPE) in soil-tea systems were investigated using a gas chromatography-electron capture detector (GC-ECD) method in young and old tea gardens. When the residual concentration of OCDPE was 100 g a.i. hm -2 in soils, the peak concentrations of OCDPE in fresh leaves of young and old tea plants were 0.365 mg/kg and 0.144 mg/kg, taking 45 days and 55 days, respectively. Equations for the accumulation curves of OCDPE in fresh leaves of young and old tea plants were C t = 0.0227e 0.0566t (R² = 0.9154) and C t = 0.0298e -0.0306t (R² = 0.7156), and were C t = 3.8435e 0.055t (R² = 0.9698) and C t = 1.5627e -0.048t (R² = 0.9634) for dissipation curves, with a half-life of 14.4 days and 12.6 days, respectively. These results have practical guiding significance for controlling tea food safety.

  17. Disinfection Byproducts in Drinking Water and Evaluation of Potential Health Risks of Long-Term Exposure in Nigeria

    PubMed Central

    Akintokun, Oyeronke A.; Adedapo, Adebusayo E.

    2017-01-01

    Levels of trihalomethanes (THMs) in drinking water from water treatment plants (WTPs) in Nigeria were studied using a gas chromatograph (GC Agilent 7890A with autosampler Agilent 7683B) equipped with electron capture detector (ECD). The mean concentrations of the trihalomethanes ranged from zero in raw water samples to 950 μg/L in treated water samples. Average concentration values of THMs in primary and secondary disinfection samples exceeded the standard maximum contaminant levels. Results for the average THMs concentrations followed the order TCM > BDCM > DBCM > TBM. EPA-developed models were adopted for the estimation of chronic daily intakes (CDI) and excess cancer incidence through ingestion pathway. Higher average intake was observed in adults (4.52 × 10−2 mg/kg-day), while the ingestion in children (3.99 × 10−2 mg/kg-day) showed comparable values. The total lifetime cancer incidence rate was relatively higher in adults than children with median values 244 and 199 times the negligible risk level. PMID:28900447

  18. Pilot study on feasibility of application of gas chromatography for the assessment of acrylamide concentration in sewage sludge.

    PubMed

    Włodarczyk, Elżbieta; Próba, Marta; Wolny, Lidia; Wojtal, Łukasz

    2014-01-01

    The aim of this study was to determine the possibility of using gas chromatography to measurement of the acrylamide concentration in sewage sludge. Acrylamide, as a toxic substance, is not indifferent to human health, but it is used in the production of plastics, dyes, adhesives, cosmetics, mortar, as well as a coagulant for water treatment, wastewater or sewage sludge conditioning. Determination of acrylamide by gas chromatography was based on standard: EPA Method 8032A "Acrylamid by gas chromatography." It consists of a bromination reaction of the compound in the presence of dibromopropendial derivative, a triple extraction with the ethyl acetate, a concentration of the eluate sample up to the 1 ml volume, and an analysis by the gas chromatography using an electron capture detector (ECD). The acrylamide concentration of was calculated according to the formula presented in the mentioned standard. All samples were performed twice (the difference between the results was not greater than 10%), and the average value of the four samples was 17.64 µg/L(-1). The presence of acrylamide in sewage sludge has been confirmed.

  19. Atmospheric bromoform at Cape Point, South Africa: an initial fixed-point data set on the African continent

    NASA Astrophysics Data System (ADS)

    Kuyper, Brett; Palmer, Carl J.; Labuschagne, Casper; Reason, Chris J. C.

    2018-04-01

    Bromoform mixing ratios in marine air were measured at Cape Point Global Atmospheric Watch Station, South Africa. This represents the first such bromoform data set recorded at this location. Manual daily measurements were made during a month-long field campaign (austral spring 2011) using a gas chromatograph-electron capture detector (GC-ECD) with a custom-built front end thermal desorption trap. The measured concentrations ranged between 4.4 and 64.6 (± 22.2 %) ppt with a mean of 24.8 ± 14.8 ppt. The highest mixing ratios recorded here occurred at, or shortly after, low tide. The diurnal cycle exhibited a morning and evening maximum with lower concentrations throughout the rest of the day. Initial analysis of the data presented indicates that the local kelp beds were the dominant source of the bromoform reported. A concentration-weighted trajectory analysis of the bromoform measurements suggests that two offshore source areas may exist. These source areas appear to be centred on the Agulhas retroflection and extend from St Helena Bay to the southwest.

  20. A NEW SW-846 METHOD FOR THE ANALYSIS OF TOXAPHENE AND TOXAPHENE CONGENERS IN SOLID AND AQUEOUS SAMPLES USING GAS CHROMATOGRAPHY / NEGATIVE ION MASS SPECTROMETRY

    EPA Science Inventory

    US EPA SW-846 methods have typically relied on dual column gas chromatography coupled with electron capture detection (GC-ECD) for analysis of low concentrations of organochlorine pesticides, including toxaphene, in environmental samples. Toxaphene is one of the most widely appl...

  1. Negative-ion formation in the explosives RDX, PETN, and TNT using the Reversal Electron Attachment Detection (READ) technique

    NASA Technical Reports Server (NTRS)

    Chutijian, Ara; Boumsellek, S.; Alajajian, S. H.

    1992-01-01

    In the search for high sensitivity and direct atmospheric sampling of trace species, techniques have been developed such as atmospheric-sampling, glow-discharge ionization (ASGDI), corona discharge, atmospheric pressure ionization (API), electron-capture detection (ECD), and negative-ion chemical ionization (NICI) that are capable of detecting parts-per-billion to parts-per-trillion concentrations of trace species. These techniques are based on positive- or negative-ion formation via charge-transfer to the target, or electron capture under multiple-collision conditions in a Maxwellian distribution of electron energies at the source temperature. One drawback of the high-pressure, corona- or glow-discharge devices is that they are susceptible to interferences either through indistinguishable product masses, or through undesired ion-molecule reactions. The ASGDI technique is relatively immune from such interferences, since at target concentrations of less than 1 ppm the majority of negative ions arises via electron capture rather than through ion-molecule chemistry. A drawback of the conventional ECD, and possibly of the ASGDI, is that they exhibit vanishingly small densities of electrons with energies in the range 0-10 millielectron volts (meV), as can be seen from a typical Maxwellian electron energy distribution function at T = 300 K. Slowing the electrons to these subthermal (less than 10 meV) energies is crucial, since the cross section for attachment of several large classes of molecules is known to increase to values larger than 10(exp -12) sq cm at near-zero electron energies. In the limit of zero energy these cross sections are predicted to diverge as epsilon(exp -1/2), where epsilon is the electron energy. In order to provide a better 'match' between the electron energy distribution function and attachment cross section, a new concept of attachment in an electrostatic mirror was developed. In this scheme, electrons are brought to a momentary halt by reversing their direction with electrostatic fields. At this turning point the electrons have zero or near-zero energy. A beam of target molecules is introduced, and the resultant negative ions extracted. This basic idea has been recently improved to allow for better reversal geometry, higher electron currents, lower backgrounds, and increased negative-ion extraction efficiency. We present herein application of the so-called reversal electron attachment detector (READ) to the study of negative-ion formation in the explosives molecules RDX, PETN, and TNT under single-collision conditions.

  2. Standard Reference Materials (SRMs) for the Calibration and Validation of Analytical Methods for PCBs (as Aroclor Mixtures)

    PubMed Central

    Poster, Dianne L.; Schantz, Michele M.; Leigh, Stefan D.; Wise, Stephen A.

    2004-01-01

    Six Standard Reference Materials (SRMs®) have been prepared by the National Institute of Standards and Technology (NIST) for the determination of PCBs as different Aroclor mixtures in methanol. Six additional SRMs of the same Aroclors in transformer oil have also been prepared. Specifically, solutions of Aroclors 1016, 1232, 1242, 1254, and 1260 have been gravimetrically prepared (individually) in methanol and transformer oil, mixed, and transferred to amber glass ampoules in approximately 1.2 mL aliquots. Gas chromatography with electron capture detection (GC-ECD) has been used to verify the gravimetric data for each solution and transformer oil SRM. Liquid chromatography was used for the isolation of the Aroclors from the transformer oil SRMs prior to GC-ECD analysis. Separate calibration solutions and oils were prepared with Aroclor levels similar to those in each methanol solution and transformer oil SRM and were processed alongside the samples. The GC-ECD response of each Aroclor was monitored relative to internal standards that were added to the complex mixtures for quantification. The gravimetric concentrations of Aroclors 1242 and 1254 in methanol were also examined by the same method of analysis (GC-ECD) using several different sources of Aroclors and two different capillary GC columns: a 5 % phenyl methylpolysiloxane phase and a relatively non-polar phase. The preparation of the materials, the gas chromatographic results, and the certified concentration values for each Aroclor SRM are described in this paper. PMID:27366608

  3. The quantification of short-chain chlorinated paraffins in sediment samples using comprehensive two-dimensional gas chromatography with μECD detection.

    PubMed

    Muscalu, Alina M; Morse, Dave; Reiner, Eric J; Górecki, Tadeusz

    2017-03-01

    The analysis of persistent organic pollutants in environmental samples is a challenge due to the very large number of compounds with varying chemical and physical properties. Chlorinated paraffins (CPs) are complex mixtures of chlorinated n-alkanes with varying chain lengths (C 10 to C 30 ) and degree of chlorination (30 to 70% by weight). Their physical-chemical properties make these compounds persistent in the environment and able to bioaccumulate in living organisms. Comprehensive two-dimensional gas chromatography (GC × GC) coupled with micro-electron capture detection (μECD) was used to separate and quantify short-chain chlorinated paraffins (SCCP) in sediment samples. Distinct ordered bands were observed in the GC × GC chromatograms pointing to group separation. Using the Classification function of the ChromaTOF software, summary tables were generated to determine total area counts to set up multilevel-calibration curves for different technical mixes. Fortified sediment samples were analyzed by GC × GC-μECD with minimal extraction and cleanup. Recoveries ranged from 120 to 130%. To further validate the proposed method for the analysis of SCCPs, the laboratory participated in interlaboratory studies for the analysis of standards and sediment samples. The results showed recoveries between 75 and 95% and z-score values <2, demonstrating that the method is suitable for the analysis of SCCPs in soil/sediment samples. Graphical abstract Quantification of SCCPs by 2D-GC-μECD.

  4. Hydrogen/deuterium exchange mass spectrometry with top-down electron capture dissociation for characterizing structural transitions of a 17 kDa protein.

    PubMed

    Pan, Jingxi; Han, Jun; Borchers, Christoph H; Konermann, Lars

    2009-09-09

    Amide H/D exchange (HDX) mass spectrometry (MS) is widely used for protein structural studies. Traditionally, this technique involves protein labeling in D(2)O, followed by acid quenching, proteolytic digestion, and analysis of peptide deuteration levels by HPLC/MS. There is great interest in the development of alternative HDX approaches involving the top-down fragmentation of electrosprayed protein ions, instead of relying on enzymatic cleavage and solution-phase separations. A number of recent studies have demonstrated that electron capture dissociation (ECD) results in fragmentation of gaseous protein ions with little or no H/D scrambling. However, the successful application of this approach for in-depth protein conformational studies has not yet been demonstrated. The current work uses horse myoglobin as a model system for assessing the suitability of HDX-MS with top-down ECD for experiments of this kind. It is found that ECD can pinpoint the locations of protected amides with an average resolution of less than two residues for this 17 kDa protein. Native holo-myoglobin (hMb) shows considerable protection from exchange in all of its helices, whereas loops are extensively deuterated. Fraying is observable at some helix termini. Removal of the prosthetic heme group from hMb produces apo-myoglobin (aMb). Both hMb and aMb share virtually the same HDX protection pattern in helices A-E, whereas helix F is unfolded in aMb. In addition, destabilization is evident for some residues close to the beginning of helix G, the end of helix H, and the C-terminus of the protein. The structural changes reported herein are largely consistent with earlier NMR data for sperm whale myoglobin, although small differences between the two systems are evident. Our findings demonstrate that the level of structural information obtainable with top-down ECD for small to medium-sized proteins considerably surpasses that of traditional HDX-MS experiments, while at the same time greatly reducing undesired amide back exchange.

  5. Optimization of microwave-assisted extraction with saponification (MAES) for the determination of polybrominated flame retardants in aquaculture samples.

    PubMed

    Fajar, N M; Carro, A M; Lorenzo, R A; Fernandez, F; Cela, R

    2008-08-01

    The efficiency of microwave-assisted extraction with saponification (MAES) for the determination of seven polybrominated flame retardants (polybrominated biphenyls, PBBs; and polybrominated diphenyl ethers, PBDEs) in aquaculture samples is described and compared with microwave-assisted extraction (MAE). Chemometric techniques based on experimental designs and desirability functions were used for simultaneous optimization of the operational parameters used in both MAES and MAE processes. Application of MAES to this group of contaminants in aquaculture samples, which had not been previously applied to this type of analytes, was shown to be superior to MAE in terms of extraction efficiency, extraction time and lipid content extracted from complex matrices (0.7% as against 18.0% for MAE extracts). PBBs and PBDEs were determined by gas chromatography with micro-electron capture detection (GC-muECD). The quantification limits for the analytes were 40-750 pg g(-1) (except for BB-15, which was 1.43 ng g(-1)). Precision for MAES-GC-muECD (%RSD < 11%) was significantly better than for MAE-GC-muECD (%RSD < 20%). The accuracy of both optimized methods was satisfactorily demonstrated by analysis of appropriate certified reference material (CRM), WMF-01.

  6. Method development for the analysis of organophosphate and pyrethroid insecticides at low parts per trillion levels in water.

    PubMed

    Wang, Dongli; Weston, Donald P; Lydy, Michael J

    2009-06-15

    In the current study, organophosphate and pyrethroid insecticides including diazinon, chlorpyrifos, bifenthrin, fenpropathrin, permethrin, lambda-cyhalothrin, cyfluthrin, cypermethrin, esfenvalerate and deltamethrin were analyzed in laboratory and field-collected water samples. Water samples were extracted and analyzed by gas chromatography/electron capture detector (GC/ECD) and gas chromatography/nitrogen-phosphorous detector (GC/NPD). Comparison of results from liquid-liquid extraction and subsequent normal phase solid-phase extraction cleanup (LLE-NPSPE), and reversed phase solid-phase extraction (RPSPE) showed that LLE-NPSPE was the better choice to extract trace amounts of pesticides from water. Pesticide recoveries from four spiked water samples using LLE-NPSPE ranged from 63.2 to 148.8% at four spiking concentrations. Method detection limits were 0.72-1.69 ng/L using four different water sources. The stability of the target pesticides in lake water was investigated at 4 degrees C for 1h, 1d, 4d, and 7d under three conditions: (1) water samples only; (2) with 20 mL hexane used as a keeper solvent; and (3) with acidification to pH 2 with HCl. Results showed that water storage without treatment resulted in slow degradation of some pesticides with storage time, storage using water acidification led to significant degradation and loss of diazinon and chlorpyrifos, while water storage with hexane as a keeper solvent showed good stability for all of the target pesticides over the 7d storage period.

  7. Model Analysis and Model Creation: Capturing the Task-Model Structure of Quantitative Item Domains. Research Report. ETS RR-06-11

    ERIC Educational Resources Information Center

    Deane, Paul; Graf, Edith Aurora; Higgins, Derrick; Futagi, Yoko; Lawless, René

    2006-01-01

    This study focuses on the relationship between item modeling and evidence-centered design (ECD); it considers how an appropriately generalized item modeling software tool can support systematic identification and exploitation of task-model variables, and then examines the feasibility of this goal, using linear-equation items as a test case. The…

  8. Characterization of a low-level unknown isomeric degradation product using an integrated online-offline top-down tandem mass spectrometry platform.

    PubMed

    Yu, Xiang; Warme, Christopher; Lee, Dinah; Zhang, Jing; Zhong, Wendy

    2013-10-01

    An integrated online-offline platform was developed combining automated online LC-MS fraction collection, continuous accumulation of selected ions (CASI), and offline top-down electron capture dissociation (ECD) tandem mass spectrometry experiments to identify a low-level, unknown isomeric degradant in a formulated drug product during an accelerated stability study. By identifying the diagnostic ions of the isoaspartic acid (isoAsp), the top-down ECD experiment showed that the Asp9 in exenatide was converted to isoAsp9 to form the unknown isomeric degradant. The platform described here provides an accurate, straightforward, and low limit of detection method for the analysis of Asp isomerization as well as other potential low-level degradants in therapeutic polypeptides and proteins. It is especially useful for unstable and time-sensitive degradants and impurities.

  9. Method for the determination of organophosphate insecticides in water, sediment and biota.

    PubMed

    Tse, Hung; Comba, Michael; Alaee, Mehran

    2004-01-01

    A procedure for the determination of 13 organophosphate insecticides (OPs) in water, sediment and biota at low ppb levels is described. Samples were extracted with dichloromethane or acetone/hexane and cleaned up with micro-column silica gel chromatography. Measurements were made by dual capillary column gas chromatography using both nitrogen-phosphorus (NPD) and electron capture (ECD) detection. Recoveries from fortified water samples ranged from 76% to 102% for all sample types. Practical detection limits ranged between 0.003 and 0.029 microg/l in natural water samples, 0.0004-0.005 microg/g w.w. for sediments, and 0.001-0.005 microg/g w.w for biota using the NPD and ECD method. Losses in sediments were experienced when sulphur was removed. Precision and accuracy were not affected in sediment samples where sulphur was not removed.

  10. In matrix derivatization of trichloroethylene metabolites in human plasma with methyl chloroformate and their determination by solid-phase microextraction-gas chromatography-electron capture detector.

    PubMed

    Mudiam, Mohana Krishna Reddy; Jain, Rajeev; Varshney, Meenu; Ch, Ratnasekhar; Chauhan, Abhishek; Goyal, Sudhir Kumar; Khan, Haider A; Murthy, R C

    2013-04-15

    Trichloroethylene (TCE) is a common industrial chemical that has been widely used as metal degreaser and for many industrial purposes. In humans, TCE is metabolized into dichloroacetic acid (DCA), trichloroacetic acid (TCA) and trichloroethanol (TCOH). A simple and rapid method has been developed for the quantitative determination of TCE metabolites. The procedure involves the in situ derivatization of TCE metabolites with methyl chloroformate (MCF) directly in diluted plasma samples followed by extraction and analysis with solid-phase microextraction (SPME) coupled to gas chromatography-electron capture detector (GC-ECD). Factors which can influence the efficiency of derivatization such as amount of MCF and pyridine (PYR), ratio of water/methanol were optimized. The factors which can affect the extraction efficiencies of SPME were screened using 2(7-4) Placket-Burman Design (PBD). A central composite design (CCD) was then applied to further optimize the most significant factors for optimum SPME extraction. The optimum factors for the SPME extraction were found to be 562.5mg of NaCl, pH at 1 and an extraction time of 22 min. Recoveries and detection limits of all three analytes in plasma were found to be in the range of 92.69-97.55% and 0.036-0.068 μg mL(-1) of plasma, respectively. The correlation coefficients were found to be in the range of 0.990-0.995. The intra- and inter-day precisions for TCE metabolites were found to be in the range of 2.37-4.81% and 5.13-7.61%, respectively. The major advantage of this method is that MCF derivatization allows conversion of TCE metabolites into their methyl esters in very short time (≤30 s) at room temperature directly in the plasma samples, thus makes it a solventless analysis. The method developed was successfully applied to the plasma samples of humans exposed to TCE. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. [Determination of dicofol residue in tea by wide-bore capillary gas chromatographic column].

    PubMed

    Zhu, M X; Wang, Y

    2000-01-01

    Dicofol residue is harmful to health. More and more countries have established the limitation of dicofol in foods. This paper describes an efficient method of determination for the dicofol residue in tea. The dicofol was extracted from the tea sample with 20% acetone-hexane, cleaned up on a column of Florisil and acidic siliceous earth (sulfuric acid 0.3 mL/g) in series. Then the column was washed with 10 mL, 20% dichloromethane-hexane, the flow rate was 1 mL/min. At last dicofol was hydrolyzed with potassium hydroxide solution, forming p,p'-dichlorobenzophenone(DBP), which was separated from other ingredients through wide-bore capillary(LZ-II, 25 m x 0.53 mm i.d.) and determinated by gas chromatography with electron capture detector(ECD), using Aldrin as internal standard. When the mass ratio of dicofol was in the range of 0.05-3.0 mg/kg, the recoveries were 78%-104% and the limit of determination was 0.5 microgram/kg. This method is simple, sensitive and suitable for pesticide residue analysis. It can also be applied to the determination of dicofol residues in other plant samples such as vegetables, fruits and so on.

  12. DDT and Derivatives in Indicator Species of the Aquatic Food Web of Rangsit Agricultural Area, Central Thailand

    PubMed Central

    Siriwong, W.; Thirakhupt, K.; Sitticharoenchai, D.; Rohitrattana, J.; Thongkongowm, P.; Borjan, M.; Robson, M.

    2009-01-01

    The presence of DDT and derivatives in the food web of freshwater ecosystems of Rangsit agricultural area, Pathum Thani Province, Thailand were investigated from June 2004 to May 2007. By using gas chromatography (GC) with micro electron capture detector (μ ECD), DDT and derivatives in water, sediment, and fifteen indicator species i.e., 2 producers; Eichhornia crassipes and plankton (phyto- and zoo- plankton), an herbivore; Trichogaster microlepis (3) 3 omnivores; Trichogaster trichopterus, Oreochromis niloticus, and Puntius gonionotus, 6 carnivores; Channa striatus, Oxyeleotris marmoratus, Macrognathus siamensis, Parambassis siamensis, Anabas testudineus, and Pristolepis fasciatus, and 3 detritivores; Macrobrachium lanchesteri, Pomacea sp., and Filopaludina mertensi were measured. Results show low concentration levels (part per billion) of DDT & derivatives in each food web compartment i.e. water, sediment, aquatic plant, plankton, fish, and invertebrates. Magnification patterns, i.e. bioconcentration, bioaccumulation, and biomagnification, based on habitat and foraging behavior of selected freshwater species indicates that DDT & derivatives can accumulate and be magnified through the food chain from the lowest up to the highest trophic level. Therefore, the presence of residues and the evidence of magnification patterns can be observed as ecological indicators for evaluating ecological health risk. PMID:20161116

  13. Development and Validation of GC-ECD Method for the Determination of Metamitron in Soil

    PubMed Central

    Tandon, Shishir; Kumar, Satyendra; Sand, N. K.

    2015-01-01

    This paper aims at developing and validating a convenient, rapid, and sensitive method for estimation of metamitron from soil samples.Determination andquantification was carried out by Gas Chromatography on microcapillary column with an Electron Capture Detector source. The compound was extracted from soil using methanol and cleanup by C-18 SPE. After optimization, the method was validated by evaluating the analytical curves, linearity, limits of detection, and quantification, precision (repeatability and intermediate precision), and accuracy (recovery). Recovery values ranged from 89 to 93.5% within 0.05- 2.0 µg L−1 with average RSD 1.80%. The precision (repeatability) ranged from 1.7034 to 1.9144% and intermediate precision from 1.5685 to 2.1323%. Retention time was 6.3 minutes, and minimum detectable and quantifiable limits were 0.02 ng mL−1 and 0.05 ng g−1, respectively. Good linearity (R 2 = 0.998) of the calibration curves was obtained over the range from 0.05 to 2.0 µg L−1. Results indicated that the developed method is rapid and easy to perform, making it applicable for analysis in large pesticide monitoring programmes. PMID:25733978

  14. Dissipation of Flonicamid in Honeysuckle and Its Transfer during Brewing Process.

    PubMed

    Wang, Yujie; Xue, Jian; Jin, Hongyu; Ma, Shuangcheng

    2017-05-01

    The dissipation of flonicamid in Honeysuckle and transfer pattern from Honeysuckle to its tea infusion were investigated. Flonicamid was applied on Honeysuckle crop at two dosages, 60 g of active gradient per hectare (g a.i. hm -2 ) and 180 g a.i. hm -2 (recommended and triple the recommended) in Fenqiu, Henan Province in 2015 and 2016. Gas Chromatography-Electron Capture Detector (GC-ECD) detection methods were developed for the analysis of flonicamid residues in honeysuckles and its infusion. The recoveries in both honeysuckles and its infusion ranged from 81.5 to 101.7% with relative standard deviations (RSDs) of 3.2-9.1%. The dissipations of flonicamid in Honeysuckle were found to follow the first order kinetics with half-life ranging between 2.8 and 3.2 d. After recommended dose pesticide application, contents of flonicamid residues were lower than theoretical maximum residue limit (tMRL). Flonicamid residues can easily transfer from Honeysuckle to its tea infusion and transfer rates of flonicamid decrease with the brewing temperature reduction or the brewing times increase. These results are helpful to establish maximum residue limit and develop guidance on the appropriate and secure use of flonicamid in Honeysuckle.

  15. Preparation of porous aromatic framework/ionic liquid hybrid composite coated solid-phase microextraction fibers and their application in the determination of organochlorine pesticides combined with GC-ECD detection.

    PubMed

    Wu, Mingxue; Chen, Gang; Liu, Ping; Zhou, Weihong; Jia, Qiong

    2016-01-07

    A novel hybrid material incorporating porous aromatic frameworks and an ionic liquid, 1-(triethoxy silyl)propyl-3-aminopropyl imidazole hexafluorophosphate, was prepared as solid-phase microextraction coating and employed for the extraction of organochlorine pesticides. Combining the advantages of porous aromatic frameworks and an ionic liquid, the fiber exhibited a high adsorption capacity for organochlorine pesticides. Under optimized experimental conditions, enhancement factors of 247-1696 were obtained with good linearity in the range of 1-500 μg L(-1). The detection limits and quantification limits were determined to be in the range of 0.11-0.29 μg L(-1) and 0.35-0.93 μg L(-1). The relative standard deviations for six replicates of organochlorine pesticides were in the range of 4.4%-7.2% and 5.7%-10.1% for one fiber and fiber-to-fiber, respectively. By coupling with a gas chromatography-electron capture detector, the novel fiber was successfully used for the determination of organochlorine pesticides in juice and milk samples with recoveries of 76.1%-121.3%.

  16. Comparison pesticide residue levels in the surface of Bertam River in Cameron Highlands, Pahang

    NASA Astrophysics Data System (ADS)

    Haron, S. H.; Ismail B., S.

    2015-09-01

    The presence of pesticide residues in the surface water of Bertam River in the agricultural areas of Cameron Highlands in Pahang, Malaysia was monitored from May to October 2014. The sampling sites were located at 10 sampling points along the Bertam River in the vegetable planting areas. The extraction method of the pesticide (organophosphate/pyrethroid) from the river samples used solid phase extraction followed by gas chromatography (with electron capture detector, ECD). Insecticides, cypermethrin and chlorpyrifos were found in the surface water of Bertam River. High level concentrations of those insecticides in the river were observed during the period from May to October 2014, a period which included both seasons (wet and dry seasons). The highest concentration of 2.66 µg/mL and 1.23 µg/mL of cypermethrin was observed during the wet and dry seasons respectively. This could be due to the frequent usage of the above-mentioned insecticides coupled with contamination that could have originated from the application sites. Meanwhile, the lowest concentration detected in the surface water was chlorpyrifos (0.11 µg/mL and 0.17 µg/mL) during the dry and wet seasons, respectively.

  17. Behavior of Thiophanate Methyl and Propiconazole in Grape and Mango Fruits Under the Egyptian Field Conditions.

    PubMed

    Soliman, Amira Sh; Helmy, Rania M A; Nasr, Islam N; Abbas, Mohamed S; Mahmoud, Hend A; Jiang, Wayne

    2017-05-01

    This research aims at determining residues of thiophanate methyl and propiconazole in grape and mango fruits as an indication for their persistence in this environmental compartment. Fruit extracts were analyzed for thiophanate methyl using High Performance Liquid Chromatography and using Gas Chromatography Electron Capture Detector (GC/ECD), respectively. The results indicated that propiconazole had a less environmental impact since propiconazole had shorter residue half-lives which were 1.24 and 1.19 days in grape and mango fruits, respectively, while thiophanate methyl had half-lives of 2.49 and 2.64 days in mango and grape, respectively. The degradation rates of propiconazole in grape and mango fruits did not change significantly and neither did those of thiophanate methyl. According to the maximum residue level, the pre-harvest intervals of propiconazole were set to be 3 and 7 days for grape and mango fruits, respectively, and the pre-harvest intervals for thiophanate methyl were 15 days for both grape and mango fruits. Propiconazole was generally considered to be less hazardous to humans and will leave the environment less altered because of its faster degradation than that of thiophanate methyl.

  18. Determination of endrin and δ-keto endrin in five food products of animal origin using GC-μECD: A modified QuEChERS approach to traditional detection.

    PubMed

    Rahman, Md Musfiqur; Lee, Han Sol; Abd El-Aty, A M; Kabir, Md Humayun; Chung, Hyung Suk; Park, Jong-Hyouk; Kim, Mi-Ra; Kim, Ji-Hyun; Shin, Ho-Chul; Shin, Sung Shik; Shim, Jae-Han

    2018-10-15

    A simple quick, easy, cheap, effective, rugged, and safe (QuEChERS)-based method was developed for the analysis of endrin and its metabolite, δ-keto endrin, in five animal-derived food products (chicken, pork, beef, egg, and milk) using a gas chromatography-micro electron capture detector (GC-μECD). Samples were extracted with acidified acetonitrile, salted out with magnesium sulfate and sodium acetate, and finally purified with a dual layer solid-phase extraction cartridge (SPE) that contains both Supelclean ENVI-Carb (upper layer) and primary secondary amine (lower layer) SPE sorbents. A seven-point external calibration curve was constructed both for the solvent and matrix for both compounds. Good linearity was achieved for both analytes, with coefficients of determination (R 2 ) ≥ 0.9960. The limits of detection (LODs) were 0.003 mg/kg, whereas the limits of quantification (LOQ) were 0.01 mg/kg, which were 10 times lower than the extraneous maximum residue limit (EMRL) designated by CODEX Alimentarius for the specified matrices. The method was validated via recovery performances in triplicates, with three fortification levels equivalent to LOQ, 2 × LOQ, and 10 × LOQ. The method provided excellent recoveries, ranging between 75.63 and 117.92%, with relative standard deviations (RSD) ≤ 8.52% for both analytes in various matrices. The developed method was successfully applied to monitor market samples collected from 20 different places throughout the Republic of Korea, and none of the tested analytes were found in the analyzed samples. Conclusively, we could propose that the current method can be used for routine analysis of endrin and δ-keto endrin in any type of fatty food matrix. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Structure dependent antioxidant capacity of phlorotannins from Icelandic Fucus vesiculosus by UHPLC-DAD-ECD-QTOFMS.

    PubMed

    Hermund, Ditte B; Plaza, Merichel; Turner, Charlotta; Jónsdóttir, Rosa; Kristinsson, Hordur G; Jacobsen, Charlotte; Nielsen, Kristian Fog

    2018-02-01

    Brown algae are rich in polyphenolic compounds, phlorotannins, which have been found to possess high in vitro antioxidant capacity, especially DPPH radical scavenging activity, due to the high number of hydroxyl groups. Whereas, the overall antioxidant capacity of brown algae extracts has been widely studied, the antioxidant capacity of individual phlorotannins has been rarely explored. The aim of this study was to determine the structure dependant antioxidant capacity of phlorotannins from Icelandic brown algae, Fucus vesiculosus. The antioxidant capacity of individual phlorotannins was determined by an on-line method using liquid chromatography and an electrochemical detector followed by quadrupole Time of Flight mass spectrometry (UHPLC-DAD-ECD-QTOFMS). Tentative structural elucidation of 13 phlorotannin isomers from EAF was obtained by LC-DAD-QTOFMS, ranging from 374 to 870Da. On-line determination of antioxidant capacity of the individual phlorotannins generally showed that low molecular phlorotannins exhibited higher antioxidant capacity and that the capacity decreased with polymerisation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. A Novel Interaction of Ecdysoneless (ECD) Protein with R2TP Complex Component RUVBL1 Is Required for the Functional Role of ECD in Cell Cycle Progression.

    PubMed

    Mir, Riyaz A; Bele, Aditya; Mirza, Sameer; Srivastava, Shashank; Olou, Appolinaire A; Ammons, Shalis A; Kim, Jun Hyun; Gurumurthy, Channabasavaiah B; Qiu, Fang; Band, Hamid; Band, Vimla

    2015-12-28

    Ecdysoneless (ECD) is an evolutionarily conserved protein whose germ line deletion is embryonic lethal. Deletion of Ecd in cells causes cell cycle arrest, which is rescued by exogenous ECD, demonstrating a requirement of ECD for normal mammalian cell cycle progression. However, the exact mechanism by which ECD regulates cell cycle is unknown. Here, we demonstrate that ECD protein levels and subcellular localization are invariant during cell cycle progression, suggesting a potential role of posttranslational modifications or protein-protein interactions. Since phosphorylated ECD was recently shown to interact with the PIH1D1 adaptor component of the R2TP cochaperone complex, we examined the requirement of ECD phosphorylation in cell cycle progression. Notably, phosphorylation-deficient ECD mutants that failed to bind to PIH1D1 in vitro fully retained the ability to interact with the R2TP complex and yet exhibited a reduced ability to rescue Ecd-deficient cells from cell cycle arrest. Biochemical analyses demonstrated an additional phosphorylation-independent interaction of ECD with the RUVBL1 component of the R2TP complex, and this interaction is essential for ECD's cell cycle progression function. These studies demonstrate that interaction of ECD with RUVBL1, and its CK2-mediated phosphorylation, independent of its interaction with PIH1D1, are important for its cell cycle regulatory function. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  1. A Novel Interaction of Ecdysoneless (ECD) Protein with R2TP Complex Component RUVBL1 Is Required for the Functional Role of ECD in Cell Cycle Progression

    PubMed Central

    Mir, Riyaz A.; Bele, Aditya; Mirza, Sameer; Srivastava, Shashank; Olou, Appolinaire A.; Ammons, Shalis A.; Kim, Jun Hyun; Gurumurthy, Channabasavaiah B.; Qiu, Fang; Band, Hamid

    2015-01-01

    Ecdysoneless (ECD) is an evolutionarily conserved protein whose germ line deletion is embryonic lethal. Deletion of Ecd in cells causes cell cycle arrest, which is rescued by exogenous ECD, demonstrating a requirement of ECD for normal mammalian cell cycle progression. However, the exact mechanism by which ECD regulates cell cycle is unknown. Here, we demonstrate that ECD protein levels and subcellular localization are invariant during cell cycle progression, suggesting a potential role of posttranslational modifications or protein-protein interactions. Since phosphorylated ECD was recently shown to interact with the PIH1D1 adaptor component of the R2TP cochaperone complex, we examined the requirement of ECD phosphorylation in cell cycle progression. Notably, phosphorylation-deficient ECD mutants that failed to bind to PIH1D1 in vitro fully retained the ability to interact with the R2TP complex and yet exhibited a reduced ability to rescue Ecd-deficient cells from cell cycle arrest. Biochemical analyses demonstrated an additional phosphorylation-independent interaction of ECD with the RUVBL1 component of the R2TP complex, and this interaction is essential for ECD's cell cycle progression function. These studies demonstrate that interaction of ECD with RUVBL1, and its CK2-mediated phosphorylation, independent of its interaction with PIH1D1, are important for its cell cycle regulatory function. PMID:26711270

  2. Comparison of nitrous oxide (N2O) analyzers for high-precision measurements of atmospheric mole fractions

    NASA Astrophysics Data System (ADS)

    Lebegue, B.; Schmidt, M.; Ramonet, M.; Wastine, B.; Yver Kwok, C.; Laurent, O.; Belviso, S.; Guemri, A.; Philippon, C.; Smith, J.; Conil, S.; Jost, H. J.; Crosson, E. R.

    2015-10-01

    Over the last few decades, in-situ measurements of atmospheric N2O mole fractions have been performed using gas chromatographs (GCs) equipped with electron capture detectors (ECDs). When trying to meet the World Meteorological Organization's (WMO) quality goal, this technique becomes very challenging as the detectors are highly non-linear and the GCs at remote stations require a considerable amount of maintenance by qualified technicians to maintain good short-term and long-term repeatability. With more robust optical spectrometers being now available for N2O measurements, we aim to identify a robust and stable analyzer that can be integrated into atmospheric monitoring networks, such as the Integrated Carbon Observation System (ICOS). In this study, we tested seven analyzers that were developed and commercialized from five different companies and compared the results with established techniques. Each instrument was characterized during a time period of approximately eight weeks. The test protocols included the characterization of the short-term and long-term repeatability, drift, temperature dependence, linearity and sensitivity to water vapor. During the test period, ambient air measurements were compared under field conditions at the Gif-sur-Yvette station. All of the analyzers showed a standard deviation better than 0.1 ppb for the 10 min averages. Some analyzers would benefit from improvements in temperature stability to reduce the instrument drift, which could then help in reducing the frequency of calibrations. For most instruments, the water vapor correction algorithms applied by companies are not sufficient for high-precision atmospheric measurements, which results in the need to dry the ambient air prior to analysis.

  3. Application of gas chromatography to analysis of spirit-based alcoholic beverages.

    PubMed

    Wiśniewska, Paulina; Śliwińska, Magdalena; Dymerski, Tomasz; Wardencki, Waldemar; Namieśnik, Jacek

    2015-01-01

    Spirit-based beverages are alcoholic drinks; their production processes are dependent on the type and origin of raw materials. The composition of this complex matrix is difficult to analyze, and scientists commonly choose gas chromatography techniques for this reason. With a wide selection of extraction methods and detectors it is possible to provide qualitative and quantitative analysis for many chemical compounds with various functional groups. This article describes different types of gas chromatography techniques and their most commonly used associated extraction techniques (e.g., LLE, SPME, SPE, SFE, and SBME) and detectors (MS, TOFMS, FID, ECD, NPD, AED, O or EPD). Additionally, brief characteristics of internationally popular spirit-based beverages and application of gas chromatography to the analysis of selected alcoholic drinks are presented.

  4. Comprehensive Analysis of Protein Modifications by Top-down Mass Spectrometry

    PubMed Central

    Zhang, Han; Ge, Ying

    2012-01-01

    Mass spectrometry (MS)-based proteomics is playing an increasingly important role in cardiovascular research. Proteomics includes not only identification and quantification of proteins, but also the characterization of protein modifications such as post-translational modifications and sequence variants. The conventional bottom-up approach, involving proteolytic digestion of proteins into small peptides prior to MS analysis, is routinely used for protein identification and quantification with high throughput and automation. Nevertheless, it has limitations in the analysis of protein modifications mainly due to the partial sequence coverage and loss of connections among modifications on disparate portions of a protein. An alternative approach, top-down MS, has emerged as a powerful tool for the analysis of protein modifications. The top-down approach analyzes whole proteins directly, providing a “bird’s eye” view of all existing modifications. Subsequently, each modified protein form can be isolated and fragmented in the mass spectrometer to locate the modification site. The incorporation of the non-ergodic dissociation methods such as electron capture dissociation (ECD) greatly enhances the top-down capabilities. ECD is especially useful for mapping labile post-translational modifications which are well-preserved during the ECD fragmentation process. Top-down MS with ECD has been successfully applied to cardiovascular research with the unique advantages in unraveling the molecular complexity, quantifying modified protein forms, complete mapping of modifications with full sequence coverage, discovering unexpected modifications, and identifying and quantifying positional isomers and determining the order of multiple modifications. Nevertheless, top-down MS still needs to overcome some technical challenges to realize its full potential. Herein, we reviewed the advantages and challenges of top-down methodology with a focus on its application in cardiovascular research. PMID:22187450

  5. Mammalian ECD Protein Is a Novel Negative Regulator of the PERK Arm of the Unfolded Protein Response

    PubMed Central

    Olou, Appolinaire A.; Sarkar, Aniruddha; Bele, Aditya; Gurumurthy, C. B.; Mir, Riyaz A.; Ammons, Shalis A.; Mirza, Sameer; Saleem, Irfana; Urano, Fumihiko; Band, Hamid

    2017-01-01

    ABSTRACT Mammalian Ecdysoneless (ECD) is a highly conserved ortholog of the Drosophila Ecd gene product whose mutations impair the synthesis of Ecdysone and produce cell-autonomous survival defects, but the mechanisms by which ECD functions are largely unknown. Here we present evidence that ECD regulates the endoplasmic reticulum (ER) stress response. ER stress induction led to a reduced ECD protein level, but this effect was not seen in PKR-like ER kinase knockout (PERK-KO) or phosphodeficient eukaryotic translation initiation factor 2α (eIF2α) mouse embryonic fibroblasts (MEFs); moreover, ECD mRNA levels were increased, suggesting impaired ECD translation as the mechanism for reduced protein levels. ECD colocalizes and coimmunoprecipitates with PERK and GRP78. ECD depletion increased the levels of both phospho-PERK (p-PERK) and p-eIF2α, and these effects were enhanced upon ER stress induction. Reciprocally, overexpression of ECD led to marked decreases in p-PERK, p-eIF2α, and ATF4 levels but robust increases in GRP78 protein levels. However, GRP78 mRNA levels were unchanged, suggesting a posttranscriptional event. Knockdown of GRP78 reversed the attenuating effect of ECD overexpression on PERK signaling. Significantly, overexpression of ECD provided a survival advantage to cells upon ER stress induction. Taken together, our data demonstrate that ECD promotes survival upon ER stress by increasing GRP78 protein levels to enhance the adaptive folding protein in the ER to attenuate PERK signaling. PMID:28652267

  6. Validity of endothelial cell analysis methods and recommendations for calibration in Topcon SP-2000P specular microscopy.

    PubMed

    van Schaick, Willem; van Dooren, Bart T H; Mulder, Paul G H; Völker-Dieben, Hennie J M

    2005-07-01

    To report on the calibration of the Topcon SP-2000P specular microscope and the Endothelial Cell Analysis Module of the IMAGEnet 2000 software, and to establish the validity of the different endothelial cell density (ECD) assessment methods available in these instruments. Using an external microgrid, we calibrated the magnification of the SP-2000P and the IMAGEnet software. In both eyes of 36 volunteers, we validated 4 ECD assessment methods by comparing these methods to the gold standard manual ECD, manual counting of cells on a video print. These methods were: the estimated ECD, estimation of ECD with a reference grid on the camera screen; the SP-2000P ECD, pointing out whole contiguous cells on the camera screen; the uncorrected IMAGEnet ECD, using automatically drawn cell borders, and the corrected IMAGEnet ECD, with manual correction of incorrectly drawn cell borders in the automated analysis. Validity of each method was evaluated by calculating both the mean difference with the manual ECD and the limits of agreement as described by Bland and Altman. Preset factory values of magnification were incorrect, resulting in errors in ECD of up to 9%. All assessments except 1 of the estimated ECDs differed significantly from manual ECDs, with most differences being similar (< or =6.5%), except for uncorrected IMAGEnet ECD (30.2%). Corrected IMAGEnet ECD showed the narrowest limits of agreement (-4.9 to +19.3%). We advise checking the calibration of magnification in any specular microscope or endothelial analysis software as it may be erroneous. Corrected IMAGEnet ECD is the most valid of the investigated methods in the Topcon SP-2000P/IMAGEnet 2000 combination.

  7. The cell cycle regulator ecdysoneless cooperates with H-Ras to promote oncogenic transformation of human mammary epithelial cells.

    PubMed

    Bele, Aditya; Mirza, Sameer; Zhang, Ying; Ahmad Mir, Riyaz; Lin, Simon; Kim, Jun Hyun; Gurumurthy, Channabasavaiah Basavaraju; West, William; Qiu, Fang; Band, Hamid; Band, Vimla

    2015-01-01

    The mammalian ortholog of Drosophila ecdysoneless (Ecd) gene product regulates Rb-E2F interaction and is required for cell cycle progression. Ecd is overexpressed in breast cancer and its overexpression predicts shorter survival in patients with ErbB2-positive tumors. Here, we demonstrate Ecd knock down (KD) in human mammary epithelial cells (hMECs) induces growth arrest, similar to the impact of Ecd Knock out (KO) in mouse embryonic fibroblasts. Furthermore, whole-genome mRNA expression analysis of control vs. Ecd KD in hMECs demonstrated that several of the top 40 genes that were down-regulated were E2F target genes. To address the role of Ecd in mammary oncogenesis, we overexpressed Ecd and/or mutant H-Ras in hTERT-immortalized hMECs. Cell cycle analyses revealed hMECs overexpressing Ecd+Ras showed incomplete arrest in G1 phase upon growth factor deprivation, and more rapid cell cycle progression in growth factor-containing medium. Analyses of cell migration, invasion, acinar structures in 3-D Matrigel and anchorage-independent growth demonstrated that Ecd+Ras-overexpressing cells exhibit substantially more dramatic transformed phenotype as compared to cells expressing vector, Ras or Ecd. Under conditions of nutrient deprivation, Ecd+Ras-overexpressing hMECs exhibited better survival, with substantial upregulation of the autophagy marker LC3 both at the mRNA and protein levels. Significantly, while hMECs expressing Ecd or mutant Ras alone did not form tumors in NOD/SCID mice, Ecd+Ras-overexpressing hMECs formed tumors, clearly demonstrating oncogenic cooperation between Ecd and mutant Ras. Collectively, we demonstrate an important co-oncogenic role of Ecd in the progression of mammary oncogenesis through promoting cell survival.

  8. The cell cycle regulator ecdysoneless cooperates with H-Ras to promote oncogenic transformation of human mammary epithelial cells

    PubMed Central

    Bele, Aditya; Mirza, Sameer; Zhang, Ying; Ahmad Mir, Riyaz; Lin, Simon; Kim, Jun Hyun; Gurumurthy, Channabasavaiah Basavaraju; West, William; Qiu, Fang; Band, Hamid; Band, Vimla

    2015-01-01

    The mammalian ortholog of Drosophila ecdysoneless (Ecd) gene product regulates Rb-E2F interaction and is required for cell cycle progression. Ecd is overexpressed in breast cancer and its overexpression predicts shorter survival in patients with ErbB2-positive tumors. Here, we demonstrate Ecd knock down (KD) in human mammary epithelial cells (hMECs) induces growth arrest, similar to the impact of Ecd Knock out (KO) in mouse embryonic fibroblasts. Furthermore, whole-genome mRNA expression analysis of control vs. Ecd KD in hMECs demonstrated that several of the top 40 genes that were down-regulated were E2F target genes. To address the role of Ecd in mammary oncogenesis, we overexpressed Ecd and/or mutant H-Ras in hTERT-immortalized hMECs. Cell cycle analyses revealed hMECs overexpressing Ecd+Ras showed incomplete arrest in G1 phase upon growth factor deprivation, and more rapid cell cycle progression in growth factor-containing medium. Analyses of cell migration, invasion, acinar structures in 3-D Matrigel and anchorage-independent growth demonstrated that Ecd+Ras-overexpressing cells exhibit substantially more dramatic transformed phenotype as compared to cells expressing vector, Ras or Ecd. Under conditions of nutrient deprivation, Ecd+Ras-overexpressing hMECs exhibited better survival, with substantial upregulation of the autophagy marker LC3 both at the mRNA and protein levels. Significantly, while hMECs expressing Ecd or mutant Ras alone did not form tumors in NOD/SCID mice, Ecd+Ras-overexpressing hMECs formed tumors, clearly demonstrating oncogenic cooperation between Ecd and mutant Ras. Collectively, we demonstrate an important co-oncogenic role of Ecd in the progression of mammary oncogenesis through promoting cell survival. PMID:25616580

  9. Deamidation and transamidation of substance P by tissue transglutaminase revealed by electron-capture dissociation fourier transform mass spectrometry.

    PubMed

    Fornelli, Luca; Schmid, Adrien W; Grasso, Luigino; Vogel, Horst; Tsybin, Yury O

    2011-01-10

    Tissue transglutaminase (tTGase) catalyzes both deamidation and transamidation of peptides and proteins by using a peptidyl glutamine as primary substrate. A precise consensus sequence for the enzyme is unknown and the ratio between deamidated and transamidated (or cross-linked) reaction products is highly substrate-dependent. Due to its overlapping body distribution with tTGase and ease of manipulation with tandem mass spectrometry, we used the neuropeptide substance P as a model to investigate the associated enzymatic kinetics and reaction products. Online liquid-chromatography Fourier-transform ion-cyclotron-resonance mass spectrometry (FT-ICR MS) combined with electron-capture dissociation (ECD) was employed to study the tTGase-induced modifications of substance P. A particular strength of ECD for peptide-enzyme reaction product monitoring is its ability to distinguish isomeric amino acids, for example, Glu and iso-Glu, by signature product ions. Our studies show that the primary reaction observed is deamidation, with the two consecutive glutamine residues converted sequentially into glutamate: first Gln(5) , and subsequently Gln(6) . We then applied ECD FT-ICR MS to identify the transamidation site on an enzymatically cross-linked peptide, which turned out to correspond to Gln(5) . Three populations of substance-P dimers were detected that differed by the number of deamidated Gln residues. The higher reactivity of Gln(5) over Gln(6) was further confirmed by cross-linking SP with monodansylcadaverine (MDC). Overall, our approach described herein is of a general importance for mapping both enzymatically induced post-translational protein modifications and cross-linking. Finally, in vitro Ca-signaling assays revealed that the main tTGase reaction product, the singly deamidated SP (RPKPEQFFGLM-NH(2) ), has increased agonist potency towards its natural receptor, thus confirming the biologically relevant role of deamidation. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Mammalian ECD Protein Is a Novel Negative Regulator of the PERK Arm of the Unfolded Protein Response.

    PubMed

    Olou, Appolinaire A; Sarkar, Aniruddha; Bele, Aditya; Gurumurthy, C B; Mir, Riyaz A; Ammons, Shalis A; Mirza, Sameer; Saleem, Irfana; Urano, Fumihiko; Band, Hamid; Band, Vimla

    2017-09-15

    Mammalian Ecdysoneless (ECD) is a highly conserved ortholog of the Drosophila Ecd gene product whose mutations impair the synthesis of Ecdysone and produce cell-autonomous survival defects, but the mechanisms by which ECD functions are largely unknown. Here we present evidence that ECD regulates the endoplasmic reticulum (ER) stress response. ER stress induction led to a reduced ECD protein level, but this effect was not seen in PKR-like ER kinase knockout (PERK-KO) or phosphodeficient eukaryotic translation initiation factor 2α (eIF2α) mouse embryonic fibroblasts (MEFs); moreover, ECD mRNA levels were increased, suggesting impaired ECD translation as the mechanism for reduced protein levels. ECD colocalizes and coimmunoprecipitates with PERK and GRP78. ECD depletion increased the levels of both phospho-PERK (p-PERK) and p-eIF2α, and these effects were enhanced upon ER stress induction. Reciprocally, overexpression of ECD led to marked decreases in p-PERK, p-eIF2α, and ATF4 levels but robust increases in GRP78 protein levels. However, GRP78 mRNA levels were unchanged, suggesting a posttranscriptional event. Knockdown of GRP78 reversed the attenuating effect of ECD overexpression on PERK signaling. Significantly, overexpression of ECD provided a survival advantage to cells upon ER stress induction. Taken together, our data demonstrate that ECD promotes survival upon ER stress by increasing GRP78 protein levels to enhance the adaptive folding protein in the ER to attenuate PERK signaling. Copyright © 2017 Olou et al.

  11. Bacterial expression and purification of a heterodimeric adrenomedullin receptor extracellular domain complex using DsbC-assisted disulfide shuffling.

    PubMed

    Hill, Heather E; Pioszak, Augen A

    2013-03-01

    Adrenomedullin (AM) is a peptide hormone that is a potent vasodilator and is essential for vascular development. The AM receptor is a heterodimeric cell surface receptor composed of the calcitonin receptor-like receptor (CLR), a class B G protein-coupled receptor, in association with either of two receptor activity modifying protein (RAMP) coreceptors, RAMP2 or -3. The extracellular domains (ECDs) of CLR and the RAMPs form the primary AM binding site. Here, we present novel methodology for expression and purification of a heterodimeric AM receptor ECD complex as an MBP-CLR ECD fusion protein in association with the RAMP2 ECD. Co-expression of the RAMP2 ECD with the disulfide bond isomerase DsbC in the oxidizing cytoplasm of E. coli trxB gor enabled proper disulfide formation in vivo. The isolated RAMP2 ECD was purified to homogeneity. Co-expression of a soluble MBP-CLR ECD fusion protein with DsbC in E. coli trxB gor yielded a heterogeneous mixture of species with misfolded ECD. Incubation of affinity-purified MBP-CLR ECD in vitro with purified RAMP2 ECD, DsbC, and glutathione redox buffer promoted proper folding of the CLR ECD and formation of a stable MBP-CLR ECD:RAMP2 ECD complex that was purified by size-exclusion chromatography and which exhibited specific AM binding. Approximately 40mg of highly purified complex was obtained starting with 6L bacterial cultures for each protein. The methodology reported here will facilitate structure/function studies of the AM receptor. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Distribution of polychlorinated biphenyls and organochlorine pesticides in human breast milk from various locations in Tunisia: Levels of contamination, influencing factors, and infant risk assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ennaceur, S.; Gandoura, N.; Driss, M.R.

    The concentrations of dichlorodiphenytrichloroethane and its metabolites (DDTs), hexachlorobenzene (HCB), hexachlorocyclohexane isomers (HCHs), dieldrin, and 20 polychlorinated biphenyls (PCBs) were determined in 237 human breast milk samples collected from 12 locations in Tunisia. Gas chromatography with electron capture detector (GC-ECD) was used to identify and quantify residue levels on a lipid basis of organochlorine compounds (OCs). The predominant OCs in human breast milk were PCBs, p,p'-DDE, p,p'-DDT, HCHs, and HCB. Concentrations of DDTs in human breast milk from rural areas were significantly higher than those from urban locations (p<0.05). With regard to PCBs, we observed the predominance of mid-chlorinated congenersmore » due to the presence of PCBs with high K{sub ow} such as PCB 153, 138, and 180. Positive correlations were found between concentrations of OCs in human breast milk and age of mothers and number of parities, suggesting the influence of such factors on OC burdens in lactating mothers. The comparison of daily intakes of PCBs, DDTs, HCHs, and HCB to infants through human breast milk with guidelines proposed by WHO and Health Canada shows that some individuals accumulated OCs in breast milk close to or higher than these guidelines.« less

  13. Polychlorinated Biphenyls Water Pollution along the River Nile, Egypt

    PubMed Central

    Megahed, Ayman Mohamed; Dahshan, Hesham; Abd-El-Kader, Mahdy A.; Abd-Elall, Amr Mohamed Mohamed; Elbana, Mariam Hassan; Nabawy, Ehab; Mahmoud, Hend A.

    2015-01-01

    Ten polychlorinated biphenyl (PCB) congeners were determined in water samples collected along the River Nile using gas chromatography-electron capture detector (GC-ECD). PCB concentrations ranged from 14 to 20 μg/L, which were higher than those reported in previous studies, indicating serious PCB pollution in the River Nile. PCB congener profiles varied depending on the sampling sties. PCB-138 was the predominant congener accounting for more than 18% of total PCBs. The composition of PCB congeners in the water revealed that highly chlorinated PCB technical mixtures such as Aroclor 1254 was the main PCB production historically used in Egypt. An increasing trend in PCB levels from the upper stream to the Nile estuaries was observed. The calculated flux of PCBs indicated that 6.8 tons of PCBs is dumped into the Mediterranean Sea each year from the River Nile. The hazard quotients and carcinogenic risk caused by PCB pollution in the River Nile were above the acceptable level indicating that PCBs in the River Nile water pose adverse health effects for all age groups. Our findings revealed that PCBs possess a serious risk to the Egyptian population that depends mainly on the River Nile as a source of water. Thus, stricter legislation and regulatory controls should be applied to reduce the risk of PCBs in Egypt. PMID:26798844

  14. Removal of pesticides from white and red wines by microfiltration.

    PubMed

    Doulia, Danae S; Anagnos, Efstathios K; Liapis, Konstantinos S; Klimentzos, Demetrios A

    2016-11-05

    The aim of this work is the investigation of microfiltration in removing pesticides from a white and a red Greek wine. Six membranes with pore size 0.45μm were investigated. Two mixtures of 23 and 9 pesticides, and single pesticide solutions were added in the wine. The pesticides tested belong to 11 chemical groups. Solid phase extraction (SPE) followed by gas chromatography (GC) with electron capture detector (ECD) were performed to analyze pesticide residues of the filtered fortified wine. Distinct behavior was exhibited by each membrane. Cellulose acetate and cellulose nitrate showed higher mean pesticide removal for both wines, followed by polyethersulfone, regenerated cellulose, and polyamides. The filtration effectiveness was correlated to the membrane type and to the pesticide chemical structure and properties (octanol-water partition coefficient, water solubility) and compared for the wines tested. In most cases, the more hydrophobic pesticides (pyrethroids and aldrin) showed higher removal from red wine than white wine. Adsorption on membranes was increased by increasing hydrophobicity and decreasing hydrophilicity of organic pesticide molecule. The removal of each pesticide from its single solution was generally higher than that from its mixtures, allowing the estimation of the antagonistic and synergistic effects of pesticides in the mixtures. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Extraction and analysis methods for the determination of pyrethroid insecticides in surface water, sediments and biological tissues at environmentally relevant concentrations.

    PubMed

    Mekebri, A; Crane, D B; Blondina, G J; Oros, D R; Rocca, J L

    2008-05-01

    The aim of this study was to develop and validate chemical methods for measuring pyrethroid insecticides at environmentally relevant concentrations in different matrices. The analytes included six synthetic pyrethroids with the highest agricultural and commercial structural uses in California: bifenthrin, cyfluthrin, cypermethrin, esfenvalerate/fenvalerate, lambda-cyhalothrin, permethrin, and their corresponding stereoisomers, which includes enantiomers, diastereomers and racemic mixtures. Fortified water samples were extracted for analysis of synthetic pyrethroids using liquid-liquid extraction, while fortified sediment and fish tissue samples were extracted using pressurized fluid extraction followed by gel permeation chromatography (GPC) to remove matrix interferences. A florisil column was used for additional cleanup and fractionation of sediment and tissue extracts. Extracts were analyzed using dual column high resolution gas chromatography with electron capture detection (GC/ECD) and confirmation was obtained with gas chromatography mass spectrometry using a quadrupole ion trap detector in MS-MS mode. Method detection limits (MDLs) have been established for water (1-3 ng/L), sediment (0.5-4 ng/g dry weight) and tissue (1-3 ng/g fresh weight). Mean percent recoveries of fortified blanks and samples ranged from 75 to 115% with relative standard deviation (RSD) values less than 20% for all target compounds.

  16. Diffusive sampling of methylene chloride with solid phase microextraction.

    PubMed

    Chen, Cheng-Yao; Hsiech, Chunming; Lin, Jia-Ming

    2006-12-29

    This study examined the characteristics of a solid phase microextraction (SPME) assembly as a passive sampler to determine the short-term exposure level (STEL) of methylene chloride. Two types of SPME fibers and six sampling-related factors were chosen and nested in an L(18) Taguchi's orthogonal array. Samples were thermally desorpted and analyzed by gas chromatograph equipped with an electron capture detector (GC/ECD). The use of 85-mum Carboxen/polydimethylsiloxane (Car/PDMS) fibers resulted in greater adsorbed mass, which was highly correlated with the product of concentration and sampling time (r>0.99, p<0.0001), than 85-microm polyacrylate fibers. The sampling rate (SR) of the 85-microm Carboxen/polydimethylsiloxane fibers was not significantly affected by variations in relative humidity (0-80%) and coexistent toluene (none to 100 ppm). Variance of sampling rate was predominantly attributed to the diffusive path length (86.4%) and sampling time (5.7%). With diffusive paths of 3, 10 and 15 mm, the sampling rates of 85-microm Carboxen/polydimethylsiloxane fibers for methylene chloride were 1.4 x 10(-2), 7.7 x 10(-3) and 5.1 x1 0(-3)mL min(-1), respectively. The measured sampling rates were greater than the theoretical values, and decreased with increment of sampling time until they came to constant.

  17. [Distribution characteristics and risk assessment of organochlorine pesticides in soil from Jiufeng Mountain Range in Fujian, China].

    PubMed

    Huang, Huan-Fang; Qi, Shi-Hua; Qu, Cheng-Kai; Li, Hui; Chen, Wen-Wen; Zhang, Li; Hu, Ting; Shi, Liao

    2014-07-01

    Totally 81 surface soil samples were collected from Jiufeng Mountain Range, and 8 compounds of organochlorine pesticides (OCPs) were determined by a Ni electron capture detector (GC-ECD) to investigate the distribution, composition, source and potential health risks of these compounds in the study region. The detection ratio of HCHs and DDTs' isomers ranged from 77.78% to 100.00%. Concentrations of HCHs and DDTs in surface soils ranged from 0.97 ng x g(-1) to 247.40 ng x g(-1) (mean 10.17 ng x g(-1)) and 0.01 ng x g(-1) to 384.75 ng x g(-1) (mean 18.91 ng x g(-1)), respectively. Compared with other regions, the pollution of OCPs in Jiufeng Mountain Range stayed at a low level. The residue level in different types of lands was in the order as: paddy field > vegetable land > tea land > woodland. Source analysis indicated that Lindane and dicofol might be used recently in this area. The incremental lifetime, cancer risks (ILCRs) of different age groups (children, youths, and adults) were all within the acceptable risk range of 10(-6) to 10(-4) recommended by USEPA for carcinogenic chemicals. The residue level of OCPs in soil may not cause cancer risk for local residents basically.

  18. Comparison pesticide residue levels in the surface of Bertam River in Cameron Highlands, Pahang

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haron, S. H., E-mail: ismail@ukm.edu.my; Ismail, B. S., E-mail: sthumaira@yahoo.com

    The presence of pesticide residues in the surface water of Bertam River in the agricultural areas of Cameron Highlands in Pahang, Malaysia was monitored from May to October 2014. The sampling sites were located at 10 sampling points along the Bertam River in the vegetable planting areas. The extraction method of the pesticide (organophosphate/pyrethroid) from the river samples used solid phase extraction followed by gas chromatography (with electron capture detector, ECD). Insecticides, cypermethrin and chlorpyrifos were found in the surface water of Bertam River. High level concentrations of those insecticides in the river were observed during the period from Maymore » to October 2014, a period which included both seasons (wet and dry seasons). The highest concentration of 2.66 µg/mL and 1.23 µg/mL of cypermethrin was observed during the wet and dry seasons respectively. This could be due to the frequent usage of the above-mentioned insecticides coupled with contamination that could have originated from the application sites. Meanwhile, the lowest concentration detected in the surface water was chlorpyrifos (0.11 µg/mL and 0.17 µg/mL) during the dry and wet seasons, respectively.« less

  19. Comparison between solid phase microextraction (SPME) and hollow fiber liquid phase microextraction (HFLPME) for determination of extractables from post-consumer recycled PET into food simulants.

    PubMed

    Oliveira, Éder Costa; Echegoyen, Yolanda; Cruz, Sandra Andrea; Nerin, Cristina

    2014-09-01

    Hollow fiber liquid phase microextraction (HFLPME) and solid phase microextraction (SPME) methods for pre-concentration of contaminants (toluene, benzophenone, tetracosane and chloroform) in food simulants were investigated. For HFLPME 1-heptanol, 2-octanone and dibutyl-ether were studied as extracting solvents. Analysis by gas chromatography coupled to mass spectrometry (GC-MS), flame ionization (GC-FID) and electron capture detectors (GC-ECD) were carried out. In addition, the methods were employed to evaluate the safety in use of a PET material after the recycling process (comprising washing, extrusion and solid state polymerization (SSP)) through extractability studies of the contaminants using 10% (v/v) ethanol in deionized water and 3% (w/v) acetic acid in deionized water as food simulants in different conditions: 10 days at 40°C and 2h at 70°C. The HFLPME preconcentration method provided increased sensitivity when compared to the SPME method and allowed to analyze concentration levels below 10 µg surrogate per kg food simulant. The results of the extractability studies showed considerable reductions after the extrusion and SSP processes and indicated the compliance with regulations for using recycled PET in contact with food. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Development of an SPE/CE method for analyzing HAAs

    USGS Publications Warehouse

    Zhang, L.; Capel, P.D.; Hozalski, R.M.

    2007-01-01

    The haloacetic acid (HAA) analysis methods approved by the US Environmental Protection Agency involve extraction and derivatization of HAAs (typically to their methyl ester form) and analysis by gas chromatography (GC) with electron capture detection (ECD). Concerns associated with these methods include the time and effort of the derivatization process, use of potentially hazardous chemicals or conditions during methylation, poor recoveries because of low extraction efficiencies for some HAAs or matrix effects from sulfate, and loss of tribromoacetic acid because of decarboxylation. The HAA analysis method introduced here uses solid-phase extraction (SPE) followed by capillary electrophoresis (CE) analysis. The method is accurate, reproducible, sensitive, relatively safe, and easy to perform, and avoids the use of large amounts of solvent for liquid-liquid extraction and the potential hazards and hassles of derivatization. The cost of analyzing HAAs using this method should be lower than the currently approved methods, and utilities with a GC/ECD can perform the analysis in-house.

  1. Structure-function analysis of the extracellular domains of the Duffy antigen/receptor for chemokines: characterization of antibody and chemokine binding sites.

    PubMed

    Tournamille, Christophe; Filipe, Anne; Wasniowska, Kazimiera; Gane, Pierre; Lisowska, Elwira; Cartron, Jean-Pierre; Colin, Yves; Le Van Kim, Caroline

    2003-09-01

    The Duffy antigen/receptor for chemokines (DARC), a seven-transmembrane glycoprotein carrying the Duffy (Fy) blood group, acts as a widely expressed promiscuous chemokine receptor. In a structure-function study, we analysed the binding of chemokines and anti-Fy monoclonal antibodies (mAbs) to K562 cells expressing 39 mutant forms of DARC with alanine substitutions spread out on the four extracellular domains (ECDs). Using synthetic peptides, we defined previously the Fy6 epitope (22-FEDVW-26), and we characterized the Fya epitope as the linear sequence 41-YGANLE-46. In agreement with these results, mutations of F22-E23, V25 and Y41, G42, N44, L45 on ECD1 abolished the binding of anti-Fy6 and anti-Fya mAbs to K562 cells respectively, Anti-Fy3 binding was abolished by D58-D59 (ECD1), R124 (ECD2), D263 and D283 (ECD4) substitutions. Mutations of C51 (ECD1), C129 (ECD2), C195 (ECD3) and C276 (ECD4 severely reduced anti-Fy3 and CXC-chemokine ligand 8 (CXCL-8) binding. CXCL-8 binding was also abrogated by mutations of F22-E23, P50 (ECD1) and D263, R267, D283 (ECD4). These results defined the Fya epitope and suggested that (1) two disulphide bridges are involved in the creation of an active chemokine binding pocket; (2) a limited number of amino acids in ECDs 1-4 participate in CXCL-8 binding; and (3) Fy3 is a conformation-dependent epitope involving all ECDs. We also showed that N-glycosylation of DARC occurred on N16SS and did not influence antibody and chemokine binding.

  2. Development of a sample preparation method for the analysis of current-use pesticides in sediment using gas chromatography.

    PubMed

    Wang, Dongli; Weston, Donald P; Ding, Yuping; Lydy, Michael J

    2010-02-01

    Pyrethroid insecticides have been implicated as the cause of sediment toxicity to Hyalella azteca in both agricultural and urban areas of California; however, for a subset of these toxic sediments (approximately 30%), the cause of toxicity remains unidentified. This article describes the analytical method development for seven additional pesticides that are being examined to determine if they might play a role in the unexplained toxicity. A pressurized liquid extraction method was optimized to simultaneously extract diazinon, methyl parathion, oxyfluorfen, dicofol, fenpropathrin, pyraclostrobin, and indoxacarb from sediment, and the extracts were cleaned using a two-step solid-phase extraction procedure. The final extract was analyzed for the target pesticides by gas chromatography/nitrogen-phosphorus detector (GC/NPD), and gas chromatography/electron capture detector (GC/ECD), after sulfur was removed by shaking with copper and cold crystallization. Three sediments were used as reference matrices to assess method accuracy and precision. Method detection limits were 0.23-1.8 ng/g dry sediment using seven replicates of sediment spiked at 1.0 ng/g dry sediment. Recoveries ranged from 61.6 to 118% with relative standard deviations of 2.1-17% when spiked at 5.0 and 50 ng/g dry sediment. The three reference sediments, spiked with 50 ng/g dry weight of the pesticide mixture, were aged for 0.25, 1, 4, 7, and 14 days. Recoveries of the pesticides in the sediments generally decreased with increased aging time, but the magnitude of the decline was pesticide and sediment dependent. The developed method was applied to field-collected sediments from the Central Valley of California.

  3. Monitoring heavy metals, residual agricultural chemicals and sulfites in traditional herbal decoctions.

    PubMed

    Yu, In-Sil; Lee, Jeong-Sook; Kim, Sung-Dan; Kim, Yun-Hee; Park, Hae-Won; Ryu, Hoe-Jin; Lee, Jib-Ho; Lee, Jeong-Mi; Jung, Kweon; Na, Cheol; Joung, Jin-Yong; Son, Chang-Gue

    2017-03-14

    Asian traditional herbal preparations are frequently considered for the contamination with undeclared toxic or hazardous substances. The aim of this study was to determine the toxic heavy metals, pesticides and sulfur dioxide in decoctions that is a common form of final utilization in Korea. A total of 155 decoctions composed of multi-ingredient traditional herbs were randomly sampled from Seoul in Korea between 2013 and 2014. For each decoction, the concentrations of four heavy metals (arsenic, cadmium, lead and mercury), 33 pesticides and sulfur dioxide were analyzed using inductively coupled plasma mass spectrometry (ICP-MS), mercury analyzer, gas chromatography/nitrogen phosphorous detector (GC/NPD), gas chromatography/micro electron capture detector (GC/μECD), and Monier-Williams method respectively. One hundred fifty-two of One hundred fifty-five decoctions (98.1%) contained one of three heavy metals (96.1% for As, 97.4% for Cd, and 90.3% for Pb, 0.0% for Hg). Their average concentrations (77.0 ± 79.7 ug/kg for As, 20.4 ± 23.7 ug/kg for Cd, and 68.8 ± 76.5 ug/kg for Pb) were approximately 20% of the maximum allowable limits of vegetable or ginseng beverage described in the Korean Food Standard Codex while their 95th percentile concentrations were below than the guideline for them. None of 33 pesticides was detected in 155 decoction samples, and only one sample showed over limit of detection for residual sulfites. This study support that the contained status of toxic heavy metals, pesticides and sulfur dioxide in herbal decoctions are currently within safe level in Korea, and provide a reference data for the further studies focused on the safety herbal preparations.

  4. National Survey of Environmental Cleaning and Disinfection in Hospitals in Thailand.

    PubMed

    Apisarnthanarak, Anucha; Weber, David J; Ratz, David; Saint, Sanjay; Khawcharoenporn, Thana; Greene, M Todd

    2017-10-01

    More than 90% of Thai hospitals surveyed reported implementing environmental cleaning and disinfection (ECD) protocols. Hospital epidemiologist presence was associated with the existence of an ECD checklist (P=.01) and of ECD auditing (P=.001), while good and excellent hospital administrative support were associated with better adherence to ECD protocols (P<.001) and ECD checklists (P=.005). Infect Control Hosp Epidemiol 2017;38:1250-1253.

  5. Recent Research with the Detector for Advanced Neutron Capture Experiments (dance) at the LOS Alamos Neutron Science Center

    NASA Astrophysics Data System (ADS)

    Ullmann, J. L.

    2014-09-01

    The DANCE detector at Los Alamos is a 160 element, nearly 4π BaF2 detector array designed to make measurements of neutron capture on rare or radioactive nuclides. It has also been used to make measurements of gamma-ray multiplicity following capture and gamma-ray output from fission. Several examples of measurements are briefly discussed.

  6. Measurement area and repeatability of semiautomated assessment of corneal endothelium in the Topcon specular microscope SP-2000P and IMAGEnet system.

    PubMed

    Ding, Xiaohu; Huang, Qunxiao; Zheng, Yingfeng; Jiang, Yuzhen; Huang, Shengsong; He, Mingguang

    2012-10-01

    To investigate the repeatability of the semiautomatic assessment of corneal endothelial cells and its association with the measurement area in the Topcon SP-2000P microscope and IMAGEnet system. Specular microscopic images of 86 healthy subjects were captured and analyzed using the Topcon SP-2000P microscope and IMAGEnet system. The same images were analyzed twice, on separate days, by the same examiner using the built-in measurement tool of the IMAGEnet system. The measurement areas were defined with a frame mounted on a computer screen. Four different-sized measurement areas were chosen for the semiautomatic measurements: box A (5.4 × 13.9 cm(2)), box B (4 × 10 cm(2)), box C (4 × 7 cm(2)), and box D (2 × 5 cm(2)). Average cell size (ACS), endothelial cell density (ECD), coefficient of variance, and hexagonality were measured. Repeatability was assessed based on the limit of agreement (LOA). The means of ACS, ECD, and hexagonality were not statistically different across 4 measurement areas (analysis of variance, P > 0.05). The mean differences (bias) were modest for ACS (range, -1.9∼3.9 μm(2)), ECD (range, -27.2∼14.6 cells per square millimeter), coefficient of variance (range, -0.14∼1.00), and hexagonality (range, -1.3%∼6.8%). Limits of agreement (mean difference ± 1.96× SD) were greater in the measurements with smaller areas: limit of agreement values for ECD were 14.6 ± 99.6, -3.8 ± 101.1, -27.2 ± 179, and -15.8 ± 488 cells per square millimeter for boxes A, B, C, and D, respectively. Similar trends were found in the repeatability of ACS and hexagonality. Repeatability is improved when larger measurement areas are chosen.

  7. Endothelial cell density to predict endothelial graft failure after penetrating keratoplasty.

    PubMed

    Lass, Jonathan H; Sugar, Alan; Benetz, Beth Ann; Beck, Roy W; Dontchev, Mariya; Gal, Robin L; Kollman, Craig; Gross, Robert; Heck, Ellen; Holland, Edward J; Mannis, Mark J; Raber, Irving; Stark, Walter; Stulting, R Doyle

    2010-01-01

    To determine whether preoperative and/or postoperative central endothelial cell density (ECD) and its rate of decline postoperatively are predictive of graft failure caused by endothelial decompensation following penetrating keratoplasty to treat a moderate-risk condition, principally, Fuchs dystrophy or pseudophakic corneal edema. In a subset of Cornea Donor Study participants, a central reading center determined preoperative and postoperative ECD from available specular images for 17 grafts that failed because of endothelial decompensation and 483 grafts that did not fail. Preoperative ECD was not predictive of graft failure caused by endothelial decompensation (P = .91). However, the 6-month ECD was predictive of subsequent failure (P < .001). Among those that had not failed within the first 6 months, the 5-year cumulative incidence (+/-95% confidence interval) of failure was 13% (+/-12%) for the 33 participants with a 6-month ECD of less than 1700 cells/mm(2) vs 2% (+/-3%) for the 137 participants with a 6-month ECD of 2500 cells/mm(2) or higher. After 5 years' follow-up, 40 of 277 participants (14%) with a clear graft had an ECD below 500 cells/mm(2). Preoperative ECD is unrelated to graft failure from endothelial decompensation, whereas there is a strong correlation of ECD at 6 months with graft failure from endothelial decompensation. A graft can remain clear after 5 years even when the ECD is below 500 cells/mm(2).

  8. Effect of Diabetes Mellitus and Metformin on Central Corneal Endothelial Cell Density in Eye Bank Eyes.

    PubMed

    Chocron, Isaac M; Rai, Dinesh K; Kwon, Ji-Won; Bernstein, Nicole; Hu, Jimmy; Heo, Moonseong; Lee, Jimmy K; Gore, Patrick K; McCartney, Mitchell D; Chuck, Roy S

    2018-05-04

    To determine whether metformin use and diabetes mellitus (DM) affect central corneal endothelial cell density (ECD) by examining an eye bank corneal donor database. The Lions Eye Institute corneal donor database, which consists of 38,318 corneal samples, was examined. Associations of ECD with metformin use and DM were tested by mixed effects linear models that account for correlations of outcomes between eyes within subjects adjusting for age, intraocular lens status, and glaucoma. Subjects (N = 17,056) with observed ECD counts for both eyes are included for analysis. Average donor age was 56.3 (SD = 15.0). ECD was not associated with metformin use (mean ± SE = 2592 ± 11.9 (N = 1014) versus nonuse [2592 ± 3.0 (N = 16,042), P = 0.302]; further analysis showed that ECD was not significantly associated with metformin use in patients with diabetes. However, metformin use was significantly associated with lower ECD among patients with glaucoma: [2658 ± 50.7 (N = 27) for use versus 2789 ± 19.0 (N = 164) for nonuse, P = 0.018]. The presence of DM was significantly associated with lower ECD 2581 ± 5.6 (N = 4766) for DM versus 2595 ± 3.4 (N = 12,290) for non-DM, P = 0.031). Lower ECD was associated with DM. Lower ECD was not associated with metformin use except in a subgroup of patients with glaucoma, in which subgroup analysis showed lower ECD. The differences in ECD observed were small and unlikely to affect the suitability for transplantation of donor corneas.

  9. Implementing the Early Childhood Development Teacher Training Framework in Uganda: Gains and Challenges

    ERIC Educational Resources Information Center

    Ejuu, Godfrey

    2012-01-01

    Training of quality early childhood development (ECD) teachers is paramount in ensuring quality ECD service provision. This exploratory study focuses on the gains and challenges met in the implementation of the Uganda ECD teacher training framework. Data were obtained using questionnaires and interviews from principals and tutors of ECD teacher…

  10. Technician Consistency in Specular Microscopy Measurements: A "Real-World" Retrospective Analysis of a United States Eye Bank.

    PubMed

    Rand, Gabriel M; Kwon, Ji Won; Gore, Patrick K; McCartney, Mitchell D; Chuck, Roy S

    2017-10-01

    To quantify consistency of endothelial cell density (ECD) measurements among technicians in a single US eye bank operating under typical operating conditions. In this retrospective analysis of 51 microscopy technicians using a semiautomated counting method on 35,067 eyes from July 2007 to May 2015, technician- and date-related marginal ECD effects were calculated using linear regression models. ECD variance was correlated with the number of specular microscopy technicians. Technician mean ECDs ranged from 2386 ± 431 to 3005 ± 560 cells/mm. Nine technicians had statistically and clinically significant marginal effects. Annual mean ECDs adjusted for changes in technicians ranged from 2422 ± 433 to 2644 ± 430 cells/mm. The period of 2007 to 2009 had statistically and clinically significant marginal effects. There was a nonstatistically significant association between the number of technicians and ECD standard deviation. There was significant ECD variability associated with specular microscopy technicians and with the date of measurement. We recommend that eye banks collect data related to laboratory factors that have been shown to influence ECD variability.

  11. Probing the Gaseous Structure of a β-Hairpin Peptide with H/D Exchange and Electron Capture Dissociation

    NASA Astrophysics Data System (ADS)

    Straus, Rita N.; Jockusch, Rebecca A.

    2017-02-01

    An improved understanding of the extent to which native protein structure is retained upon transfer to the gas phase promises to enhance biological mass spectrometry, potentially streamlining workflows and providing fundamental insights into hydration effects. Here, we investigate the gaseous conformation of a model β-hairpin peptide using gas-phase hydrogen-deuterium (H/D) exchange with subsequent electron capture dissociation (ECD). Global gas-phase H/D exchange levels, and residue-specific exchange levels derived from ECD data, are compared among the wild type 16-residue peptide GB1p and several variants. High protection from H/D exchange observed for GB1p, but not for a truncated version, is consistent with the retention of secondary structure of GB1p in the gas phase or its refolding into some other compact structure. Four alanine mutants that destabilize the hairpin in solution show levels of protection similar to that of GB1p, suggesting collapse or (re)folding of these peptides upon transfer to the gas phase. These results offer a starting point from which to understand how a key secondary structural element, the β-hairpin, is affected by transfer to the gas phase. This work also demonstrates the utility of a much-needed addition to the tool set that is currently available for the investigation of the gaseous conformation of biomolecules, which can be employed in the future to better characterize gaseous proteins and protein complexes.

  12. Probing the Gaseous Structure of a β-Hairpin Peptide with H/D Exchange and Electron Capture Dissociation.

    PubMed

    Straus, Rita N; Jockusch, Rebecca A

    2017-02-01

    An improved understanding of the extent to which native protein structure is retained upon transfer to the gas phase promises to enhance biological mass spectrometry, potentially streamlining workflows and providing fundamental insights into hydration effects. Here, we investigate the gaseous conformation of a model β-hairpin peptide using gas-phase hydrogen-deuterium (H/D) exchange with subsequent electron capture dissociation (ECD). Global gas-phase H/D exchange levels, and residue-specific exchange levels derived from ECD data, are compared among the wild type 16-residue peptide GB1p and several variants. High protection from H/D exchange observed for GB1p, but not for a truncated version, is consistent with the retention of secondary structure of GB1p in the gas phase or its refolding into some other compact structure. Four alanine mutants that destabilize the hairpin in solution show levels of protection similar to that of GB1p, suggesting collapse or (re)folding of these peptides upon transfer to the gas phase. These results offer a starting point from which to understand how a key secondary structural element, the β-hairpin, is affected by transfer to the gas phase. This work also demonstrates the utility of a much-needed addition to the tool set that is currently available for the investigation of the gaseous conformation of biomolecules, which can be employed in the future to better characterize gaseous proteins and protein complexes. Graphical Abstract ᅟ.

  13. Soluble FGFR4 extracellular domain inhibits FGF19-induced activation of FGFR4 signaling and prevents nonalcoholic fatty liver disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Qiang; The First Affiliated Hospital of Xiamen University, Xiamen; Jiang, Yuan

    2011-06-17

    Highlights: {yields} Soluble FGFR4 extracellular domain (FGFR4-ECD) was effectively expressed. {yields} FGFR4-ECD inhibited FGF19-induced activation of FGFR4 signaling. {yields} FGFR4-ECD reduced palmitic acid-induced steatosis of HepG2 cells. {yields} FGFR4-ECD reduced tetracycline-induced fatty liver in mice. {yields} FGFR4-ECD partially restored tetracycline-repressed PPAR{alpha} expression. -- Abstract: Fibroblast growth factor receptor 4 (FGFR4) is a transmembrane tyrosine kinase receptor that plays a crucial role in the regulation of hepatic bile acid and lipid metabolism. FGFR4 underlies high-fat diet-induced hepatic steatosis, suggesting that inhibition of FGFR4 activation may be an effective way to prevent or treat nonalcoholic fatty liver disease (NAFLD). To determine whethermore » neutralization of FGFR4 ligands by soluble FGFR4 extracellular domain (FGFR4-ECD) can inhibit the activation of FGFR4, we constructed FGFR4-ECD expression vector and showed that FGFR4-ECD was effectively expressed in cells and secreted into culture medium. FGFR4-ECD inhibited FGF19-induced activation of FGFR4 signaling and reduced steatosis of HepG2 induced by palmitic acid in vitro. Furthermore, in a tetracycline-induced fatty liver model, expression of FGFR4-ECD in mouse liver reduced the accumulation of hepatic lipids and partially restored the expression of peroxisome proliferator-activated receptor {alpha} (PPAR{alpha}), which promotes the mitochondrial fatty acid beta-oxidation but is repressed by tetracycline. Taken together, these results demonstrate that FGFR4-ECD can block FGFR4 signaling and prevent hepatic steatosis, highlighting the potential value of inhibition of FGFR4 signaling as a method for therapeutic intervention against NAFLD.« less

  14. Overexpression of a novel cell cycle regulator ecdysoneless in breast cancer: a marker of poor prognosis in HER2/neu-overexpressing breast cancer patients.

    PubMed

    Zhao, Xiangshan; Mirza, Sameer; Alshareeda, Alaa; Zhang, Ying; Gurumurthy, Channabasavaiah Basavaraju; Bele, Aditya; Kim, Jun Hyun; Mohibi, Shakur; Goswami, Monica; Lele, Subodh M; West, William; Qiu, Fang; Ellis, Ian O; Rakha, Emad A; Green, Andrew R; Band, Hamid; Band, Vimla

    2012-07-01

    Uncontrolled proliferation is one of the hallmarks of breast cancer. We have previously identified the human Ecd protein (human ortholog of Drosophila Ecdysoneless, hereafter called Ecd) as a novel promoter of mammalian cell cycle progression, a function related to its ability to remove the repressive effects of Rb-family tumor suppressors on E2F transcription factors. Given the frequent dysregulation of cell cycle regulatory components in human cancer, we used immunohistochemistry of paraffin-embedded tissues to examine Ecd expression in normal breast tissue versus tissues representing increasing breast cancer progression. Initial studies of a smaller cohort without outcomes information showed that Ecd expression was barely detectable in normal breast tissue and in hyperplasia of breast, but high levels of Ecd were detected in benign breast hyperplasia, ductal carcinoma in situ (DCIS) and infiltrating ductal carcinoma (IDCs) of the breast. In this cohort of 104 IDC patients, Ecd expression levels showed a positive correlation with higher grade (P=0.04). Further analyses of Ecd expression using a larger, independent cohort (954) confirmed these results, with a strong positive correlation of elevated Ecd expression with higher histological grade (P=0.013), mitotic index (P=0.032), and Nottingham Prognostic Index score (P=0.014). Ecd expression was positively associated with HER2/neu (P=0.002) overexpression, a known marker of poor prognosis in breast cancer. Significantly, increased Ecd expression showed a strong positive association with shorter breast cancer specific survival (BCSS) (P=0.008) and disease-free survival (DFS) (P=0.003) in HER2/neu overexpressing patients. Taken together, our results reveal Ecd as a novel marker for breast cancer progression and show that levels of Ecd expression predict poorer survival in Her2/neu overexpressing breast cancer patients.

  15. β-Ecdysone Augments Peak Bone Mass in Mice of Both Sexes.

    PubMed

    Dai, Weiwei; Zhang, HongLiang; Zhong, Zhendong A; Jiang, Li; Chen, Haiyan; Lay, Yu-An Evan; Kot, Alexander; Ritchie, Robert O; Lane, Nancy E; Yao, Wei

    2015-08-01

    One of the strongest predictors for osteoporosis is peak bone mass. Interventions to augment peak bone mass have yet to be developed. β-Ecdysone (βEcd), a natural steroid-like compound produced by arthropods to initiate metamorphosis, is believed to have androgenic effects and so may be used to augment bone mass. The purpose of this study was to use both male and female (1) gonadal-sufficient; and (2) -insufficient mice to investigate sex differences in terms of bone development and structure after βEcd administration. Two-month-old male and female Swiss-Webster mice were randomized to receive either vehicle or βEcd (0.5 mg/kg) for 3 weeks. In a separate experiment to evaluate the effects of βEcd on sex hormone-deficient mice, gonadectomy was performed in male (orchiectomy [ORX]) and female mice (ovariectomy [OVX]). Sham-operated and the ORX/OVX mice were then treated for 3 weeks with βEcd. Primary endpoints for the study were trabecular bone structure and bone strength. In male mice, the trabecular bone volume was 0.18±0.02 in the placebo-treated (PL) and 0.23±0.02 in the βEcd-treated group (p<0.05 versus PL); and 0.09±0.01 in the ORX group (p<0.05 versus PL) and 0.12±0.01 in the ORX+βEcd group. Vertebral bone strength (maximum load) was 43±2 in PL and 51±1 in the βEcd-treated group (p<0.05 versus PL); and 30±4 in the ORX group (p<0.05 versus PL) and 37±3 in the ORX+βEcd group. In female mice, trabecular bone volume was 0.23±0.02 in PL and 0.26±0.02 in the βEcd-treated group (p<0.05 versus PL); and 0.15±0.01 in the OVX group (p<0.05 versus PL) and 0.14±0.01 in the OVX+βEcd group. Maximum load of the vertebrae was 45±2 in PL and 48±4 in the βEcd-treated group; and 39±4 in the OVX group (p<0.05 versus PL) and 44±4 in the OVX+βEcd group. These findings suggest the potential use of βEcd in the augmentation of bone mass in growing male and female mice. It may also partially prevent the detrimental effects of gonadectomy on trabecular bone. Our results support the potential use of βEcd or nature products that are rich in βEcd to augment peak bone mass. βEcd may differ from the other anabolic hormone treatments that may have severe side effects such as serious cardiac complications. However, its effects on humans remain to be determined.

  16. De novo peptide sequencing using CID and HCD spectra pairs.

    PubMed

    Yan, Yan; Kusalik, Anthony J; Wu, Fang-Xiang

    2016-10-01

    In tandem mass spectrometry (MS/MS), there are several different fragmentation techniques possible, including, collision-induced dissociation (CID) higher energy collisional dissociation (HCD), electron-capture dissociation (ECD), and electron transfer dissociation (ETD). When using pairs of spectra for de novo peptide sequencing, the most popular methods are designed for CID (or HCD) and ECD (or ETD) spectra because of the complementarity between them. Less attention has been paid to the use of CID and HCD spectra pairs. In this study, a new de novo peptide sequencing method is proposed for these spectra pairs. This method includes a CID and HCD spectra merging criterion and a parent mass correction step, along with improvements to our previously proposed algorithm for sequencing merged spectra. Three pairs of spectral datasets were used to investigate and compare the performance of the proposed method with other existing methods designed for single spectrum (HCD or CID) sequencing. Experimental results showed that full-length peptide sequencing accuracy was increased significantly by using spectra pairs in the proposed method, with the highest accuracy reaching 81.31%. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Coexistence of intracranial Langerhans cell histiocytosis and Erdheim-Chester disease in a pediatric patient: a case report.

    PubMed

    Kim, Seokhwi; Lee, Minju; Shin, Hyung Jin; Lee, Joohee; Suh, Yeon-Lim

    2016-05-01

    The co-occurrence of Langerhans cell histiocytosis (LCH) and Erdheim-Chester disease (ECD) is extremely rare and almost all cases were reported in adults. We describe a case of intracranial LCH and ECD that was confirmed by histopathological and molecular studies. A three-year-old boy presented with headache and right exophthalmos and brain magnetic resonance images (MRI) revealed multiple intracranial tumors. Whole body MRI showed osteolytic lesions typical of LCH in flat bones and osteosclerotic changes typical of ECD in long bones. Histologically, the biopsy samples from the posterior fossa and occipital skull mass revealed areas of both LCH and ECD. Immunohistochemically, the LCH contained CD1a-positive Langerhans cells and the ECD had CD1a-negative, CD68-positive foamy histiocytes. BRAF (V600E) mutations were detected in both the LCH and ECD areas. The coexistence of LCH and ECD in the same biopsy and the BRAF (V600E) mutation status in both histologic types support the recent re-classification of the histiocytic disorder into LCH, ECD, and "mixed histiocytosis", which reflects tumorigenesis for all three from a common progenitor cell.

  18. Stimulation effect of electric current density (ECD) on microbial community of a three dimensional particle electrode coupled with biological aerated filter reactor (TDE-BAF).

    PubMed

    Feng, Yan; Li, Xing; Song, Ting; Yu, Yanzhen; Qi, Jingyao

    2017-11-01

    Improving the stimulation effect of electric current density (ECD) on microbial community is critical in designing and operating TDE-BAF. This study investigated the effect of ECD at 0.00, 4.08, 6.12, 12.20, 14.25, 16.30 and 20.20A·m -2 on the removal performance, diversity and structure of microbial community in TDE-BAF. Results indicated that the ECD of 14.25A·m -2 exhibited the highest COD, TOC and NH 4 + -N average removal rates with 93.33%, 91.26% and 93.87%, respectively; Under high ECD, especially exceeding 14.25A·m -2 , the inhibition of growth and activity because of plasmatorrhexis was in agreement with the sharp biomass decline; there was no significant relation between community richness and diversity and removal efficiency below optimum ECD, while above optimal ECD, it was just the opposite; Microbial communities mainly including Hydrogenophaga, Saprospiraceae_uncultured, Delftia, Enterobacter, Pseudomonas, Pseudoxanthomonas, and Nitrosospira and physicochemical properties well explained the excellent removal performance at the optimum ECD. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Rapid analysis of cyclamate in foods and beverages by gas chromatography-electron capture detector (GC-ECD).

    PubMed

    Yu, Shengbing; Zhu, Binghui; Lv, Fen; Li, Shaoxiao; Huang, Weixiong

    2012-10-15

    A rapid method for determination of sodium cyclamate in foods and beverages was developed. Sodium cyclamate was converted to N,N-dichloridecyclohexylamine by reaction with sodium hypochlorite under acid condition. N,N-dichloridecyclohexylamine was subsequently extracted by n-hexane and determined by gas chromatography. Conditions such as derivatization time, the concentration of sodium hypochlorite and sulphuric acid were optimised. Amino acids, aliphatic amines, and food additives such as preservatives, dyes and sweeteners showed no interference for quantification of cyclamate. The correlation coefficient of calibration curve was 0.9993 in the range of 5.0-250mg/L. The limits of detection (LOD) and limits of quantification (LOQ) were calculated as three or ten times the signal-to-noise ratio (S/N), respectively. The LOD and LOQ for yellow wine and fruit juice were 0.05 and 0.2mg/L, respectively. The LOD and LOQ for cake and preserved fruit were 0.25 and 0.8mg/kg, respectively. The intra-day and inter-day RSD were 0.28% and 1.1% (n=5), respectively. The method was successfully applied for determination of cyclamate in yellow wine, cake, fruit juice and preserved fruit. This method was simple, fast, and sensitive. It was suitable for the determination of cyclamate in foods and beverages for safety and quality control inspections. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Pesticide residue levels in green beans cultivated in Souss Masa valley (Morocco) after multiple applications of bifenthrin and λ-cyhalothrin.

    PubMed

    Bouri, M; Salghi, R; Bazzi, Lh; Zarrouk, A; Rios, A; Zougagh, M

    2012-09-01

    Dissipation of bifenthrin and λ-cyhalothrin pyrethroid insecticides, under environmental conditions, was evaluated on green beans grown in experimental greenhouses (Souss Massa valley, Morocco). Pesticide residues were determined by gas chromatography with micro electron-capture detector (GC-μECD) after dichloromethane extraction and cleanup on florisil phase cartridges. In the case of field experiments, a random block scheme was employed. Each block contained 25 plants in a single row and tests were carried out in triplicates applying pesticides at the recommended doses by the manufacturers. Fruit samples were periodically taken until the end of the preharvest interval (p.i.). The results obtained showed that the p.i of bifenthrin in green bean were 4 days in the winter and 3.5 days in the spring, whereas that for λ-cyhalothrin 8 days was found in the winter and 7.5 days in the spring. Consequently, it is possible to consider the European Union maximum residue limit (EU MRL) values compatible with the proper agricultural practices used for growing green bean in the plastic greenhouse of Souss Massa valley in South Morocco. Bifenthrin had a degradation of first-order kinetics, whereas that of levels for λ-cyhalothrin residue can not be interpreted by the use of a first order model.

  1. Polychlorinated biphenyls in coastal tropical ecosystems: Distribution, fate and risk assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dodoo, D.K.; Essumang, D.K., E-mail: kofiessumang@yahoo.com; Jonathan, J.W.A.

    2012-10-15

    Polychlorinated biphenyls (PCBs) though banned still find use in most developing countries including Ghana. PCB congener residues in sediments in the coastal regions of Ghana were determined. Sediment samples (n=80) were collected between June 2008 and March 2009, extracted by the continuous soxhlet extraction using (1:1) hexane-acetone mixture for 24 h and analyzed with a CP 3800 gas chromatogram equipped with {sup 65}Ni electron capture detector (GC-ECD) and a mixed PCBs standard of the ICES 7 as marker, after clean-up. Validation of the efficiency and precision of the extraction and analytical methods were done by extracting samples spiked with 2more » ppm ICES PCB standard and a certified reference material 1941b for marine sediments from NIST, USA, and analyzed alongside the samples. Total PCBs detected in sediments during the dry and wet seasons were, respectively, 127 and 112 {mu}g/kg dry weight (dw), with a mean concentration of 120 {mu}g/kg (dw). The composition of PCB homologues in the sediments were dominated by tri-, penta- and tetra-PCBs. There was no correlation between organic carbon (OC) of the sediments and total PCBs content. Risk assessments conducted on the levels indicated that PCB levels in sediments along the coastal region of Ghana poses no significant health risk to humans.« less

  2. Levels of organochlorine pesticides in the blood of people living in areas of intensive pesticide use in Sudan.

    PubMed

    Elbashir, Ahmed B; Abdelbagi, Azhari O; Hammad, Ahmed M A; Elzorgani, Gafar A; Laing, Mark D

    2015-03-01

    Ninety-six human blood samples were collected from six locations that represent areas of intensive pesticide use in Sudan, which included irrigated cotton schemes (Wad Medani, Hasaheesa, Elmanagil, and Elfaw) and sugarcane schemes (Kenana and Gunaid). Blood samples were analyzed for organochlorine pesticide residues by gas liquid chromatography (GLC) equipped with an electron capture detector (ECD). Residues of p,p'-dichlorodiphenyldichloroethylene (DDE), heptachlor epoxide, γ-HCH, and dieldrin were detected in blood from all locations surveyed. Aldrin was not detected in any of the samples analyzed, probably due to its conversion to dieldrin. The levels of total organochlorine burden detected were higher in the blood from people in the irrigated cotton schemes (mean 261 ng ml(-1), range 38-641 ng ml(-1)) than in the blood of people from the irrigated sugarcane schemes (mean 204 ng ml(-1), range 59-365 ng ml(-1)). The highest levels of heptachlor epoxide (170 ng ml(-1)) and γ-HCH (92 ng ml(-1)) were observed in blood samples from Hasaheesa, while the highest levels of DDE (618 ng ml(-1)) and dieldrin (82 ng ml(-1)) were observed in blood samples from Wad Medani and Kenana, respectively. The organochlorine levels in blood samples seemed to decrease with increasing distance from the old irrigated cotton schemes (Wad Medani, Hasaheesa, and Elmanagil) where the heavy application of these pesticides took place historically.

  3. Assessment of pesticide residues in vegetables from the Western Usambara and Uruguru Mountains in Tanzania.

    PubMed

    Mtashobya, Lewis A

    2017-09-25

    Assessment of levels of pesticide residues in vegetables was carried out in some villages in the Western Usambara and Uluguru Mountains of Tanzania where varieties of vegetables are grown. Tomatoes and cabbages were the most popular enterprise grown all year round and therefore were selected as the model crops for this study. Analysis of the cleaned sample extracts on a gas chromatography with electron capture detector (GC-ECD) and confirmation on the Gas chromatography-mass spectrometry (GC-MS) revealed dominance of organochlorine pesticides. Organophosphorous pesticides (parathion and marathion) were only detected in some samples, however, in most cases with higher concentrations compared to organochlorine pesticides. Levels of pesticide residues detected in vegetables were up to: parathion 5.07 μg/Kg, marathion 3.73 μg/Kg, α-endosulfan 0.32 μg/Kg, β-endosulfan 0.53 μg/Kg, dieldrin 1.36 μg/Kg, γ-HCH 0.25 μg/Kg, α-HCH 0.09 μg/Kg, and p, p'-DDT 0.64 μg/Kg. These results clearly show that vegetables are contaminated with different pesticide residues. However, the total levels of pesticide residues in both tomatoes and cabbages are lower than their respective codex alimentarius maximum residue levels (MRLs). This means that the vegetables produced in the area are suitable for human consumption.

  4. [Simultaneous determination of trichloroethylene and trichloroethanol in blood by liquid-liquid extraction-gas chromatography].

    PubMed

    Ye, H P; Shao, J; Tan, S W; Shan, X Y; Shi, Y P

    2017-10-20

    Objective: To establish a method for determing the trichloroethylene(TCE)and trichloroethanol(TCOH)in blood samples by liquid-liquid extraction-gas chromatography with electron capture detector. Methods: With this method,ether was used as extraction solvent and trichloromethane was used as an internal standard. The whole blood sample was extracted with ether, and dehydrated by anhydrous sodium sulfate. Then the analytes were separated on HP-5 capillary column(30m×0.32mm×0.15μm)and detected byECD.The retention time was for qualitative analysis and the internal standard was for quantitation. Results: The standard curves of TCE and TCOH showed significant linearity between 95.5μg/L-7640.0μg/L( r =0.9997)and 19.0μg/L-1520.0μg/L( r =0.9992). The average recovery was 95.5%-103.6%.The intra-day and inter-day precisions( RSD )were 2.5%-6.8%( n =6)and 1.6%-4.3%( n =6) respectively. The detect limit of TCE and TCOH were 2.10 μg/L and 0.56μg/L(S/N=3)respectively.The blood can be kept 7 days at-20℃ refrigerator without significantly loss. Conclusion: This method is proved to be simple,practical and highly sensitive. It can satisfy the request for the determination of blood samples of humans exposed to TCE.

  5. Analysis of Cadmium Based Neutron Detector Configurations

    NASA Astrophysics Data System (ADS)

    James, Brian; Rees, Lawrence; Czirr, J. Bart

    2012-10-01

    Due to national security concerns pertaining to the smuggling of special nuclear materials and a small supply of He-3 for use in neutron detectors, there is currently a need for a new kind of neutron detector. Using Monte Carlo techniques I have studied the neutron capture efficiency of an array of cadmium wedge detectors in the presence of a californium source. By using varying numbers of wedges and comparing their capture ratios we will be better able to design future detectors.

  6. Enhancing the detector for advanced neutron capture experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Couture, A.; Mosby, S.; Baramsai, B.

    2015-05-28

    The Detector for Advanced Neutron Capture Experiments (DANCE) has been used for extensive studies of neutron capture, gamma decay, photon strength functions, and prompt and delayed fission-gamma emission. Despite these successes, the potential measurements have been limited by the data acquisition hardware. We, thus, report on a major upgrade of the DANCE data acquisition that simultaneously enables strait-forward coupling to auxiliary detectors, including high-resolution high-purity germanium detectors and neutron tagging array. Furthermore, the upgrade will enhance the time domain accessible for time-of-flight neutron measurements as well as improve the resolution in the DANCE barium fluoride crystals for photons.

  7. Conformational Sampling and Binding Site Assessment of Suppression of Tumorigenicity 2 Ectodomain

    PubMed Central

    Yang, Chao-Yie; Delproposto, James; Chinnaswamy, Krishnapriya; Brown, William Clay; Wang, Shuying; Stuckey, Jeanne A.; Wang, Xinquan

    2016-01-01

    Suppression of Tumorigenicity 2 (ST2), a member of the interleukin-1 receptor (IL-1R) family, activates type 2 immune responses to pathogens and tissue damage via binding to IL-33. Dysregulated responses contribute to asthma, graft-versus-host and autoinflammatory diseases and disorders. To study ST2 structure for inhibitor development, we performed the principal component (PC) analysis on the crystal structures of IL1-1R1, IL1-1R2, ST2 and the refined ST2 ectodomain (ST2ECD) models, constructed from previously reported small-angle X-ray scattering data. The analysis facilitates mapping of the ST2ECD conformations to PC subspace for characterizing structural changes. Extensive coverage of ST2ECD conformations was then obtained using the accelerated molecular dynamics simulations started with the IL-33 bound ST2ECD structure as instructed by their projected locations on the PC subspace. Cluster analysis of all conformations further determined representative conformations of ST2ECD ensemble in solution. Alignment of the representative conformations with the ST2/IL-33 structure showed that the D3 domain of ST2ECD (containing D1-D3 domains) in most conformations exhibits no clashes with IL-33 in the crystal structure. Our experimental binding data informed that the D1-D2 domain of ST2ECD contributes predominantly to the interaction between ST2ECD and IL-33 underscoring the importance of the D1-D2 domain in binding. Computational binding site assessment revealed one third of the total detected binding sites in the representative conformations may be suitable for binding to potent small molecules. Locations of these sites include the D1-D2 domain ST2ECD and modulation sites conformed to ST2ECD conformations. Our study provides structural models and analyses of ST2ECD that could be useful for inhibitor discovery. PMID:26735493

  8. Deleting the Redundant TSH Receptor C-Peptide Region Permits Generation of the Conformationally Intact Extracellular Domain by Insect Cells.

    PubMed

    Chen, Chun-Rong; Salazar, Larry M; McLachlan, Sandra M; Rapoport, Basil

    2015-07-01

    The TSH receptor (TSHR) extracellular domain (ECD) comprises a N-terminal leucine-rich repeat domain and an hinge region (HR), the latter contributing to ligand binding and critical for receptor activation. The crystal structure of the leucine-rich repeat domain component has been solved, but previous attempts to generate conformationally intact complete ECD or the isolated HR component for structural analysis have failed. The TSHR HR contains a C-peptide segment that is removed during spontaneous TSHR intramolecular cleavage into disulfide linked A- and B-subunits. We hypothesized that deletion of the redundant C-peptide would overcome the obstacle to generating conformationally intact TSHR ECD protein. Indeed, lacking the C-peptide region, the TSHR ECD (termed ECD-D1) and the isolated HR (termed HR-D1) were secreted into medium of insect cells infected with baculoviruses coding for these modified proteins. The identities of TSHR ECD-D1 and HR-D1 were confirmed by ELISA and immunoblotting using TSHR-specific monoclonal antibodies. The TSHR-ECD-D1 in conditioned medium was folded correctly, as demonstrated by its ability to inhibit radiolabeled TSH binding to the TSH holoreceptor. The TSHR ECD-D1 purification was accomplished in a single step using a TSHR monoclonal antibody affinity column, whereas the HR-D1 required a multistep protocol with a low yield. In conclusion, we report a novel approach to generate the TSHR ECD, as well as the isolated HR in insect cells, the former in sufficient amounts for structural studies. However, such studies will require previous complexing of the ECD with a ligand such as TSH or a thyroid-stimulating antibody.

  9. Dual kidney transplantation: a case-control comparison with single kidney transplantation from standard and expanded criteria donors.

    PubMed

    Moore, Phillip S; Farney, Alan C; Sundberg, Aimee K; Rohr, Michael S; Hartmann, Erica L; Iskandar, Samy S; Gautreaux, Michael D; Rogers, Jeffrey; Doares, William; Anderson, Teresa K; Adams, Patricia L; Stratta, Robert J

    2007-06-27

    The purpose of this study was to perform a case-matched cohort analysis of dual kidney transplantation (DKT) from expanded criteria donors (ECDs) compared to single kidney transplantation (SKT) from concurrent ECDs and standard criteria donors (SCDs, defined as non-ECD). Deceased donor (DD) kidney transplants (KTs) performed at a single center between October 2001 and February 2006 were reviewed retrospectively. If the calculated DD creatinine clearance (CrCl) was <65 mL/min, then the kidneys were transplanted dually into a single patient. In the case of DKT and SKT from ECDs, low risk patients were chosen and informed consent was obtained. Patients in each group were matched for age, gender, race, transplant number, and time of transplant. Of 294 adult DD KTs performed, 16 (5%) were DKTs, which were matched with 16 concurrent SCD and 16 ECD SKT patients. Mean donor age in years (65 DKT vs. 33 SCD vs. 61 ECD; P<0.0001) and mean donor CrCl in ml/min (54 DKT vs. 91 SCD vs. 76 ECD; P=0.002) were different between groups. Patient survival was 100% in the DKT and SCD SKT groups and 94% in the ECD SKT group (mean follow up 23-28 months); graft survival rates in the DKT, SCD, and ECD groups were 81%, 81%, and 94%, respectively (P=NS). Graft function, rejection, and morbidity were similar between groups. DKT using kidneys from marginal ECDs is a viable option to counteract the growing shortage of available organs. Excellent short-term results and renal function can be achieved with older, low nephron mass donors provided that both kidneys are transplanted into a single recipient.

  10. Outcomes of dual adult kidney transplants in the United States: an analysis of the OPTN/UNOS database.

    PubMed

    Gill, Jagbir; Cho, Yong W; Danovitch, Gabriel M; Wilkinson, Alan; Lipshutz, Gerald; Pham, Phuong-Thu; Gill, John S; Shah, Tariq; Bunnapradist, Suphamai

    2008-01-15

    The organ shortage has resulted in increased use of kidneys from expanded criteria donors (ECD). For ECD kidneys unsuitable for single use, dual kidney transplants (DKT) may be possible. There are limited data comparing outcomes of DKT to single kidney ECD transplants, making it unclear where DKT fits in the current allocation scheme. Our purpose was to compare outcomes of DKT and ECD transplants in the United States. From 2000 to 2005, a total of 625 DKT, 7686 single kidney ECD, and 6,044 SCD transplants from donors aged>or=50 years were identified from the Organ Procurement and Transplantation Network/United Network for Organ Sharing data. Allograft survival was the primary outcome. DKT comprised 4% of kidney transplants from donors aged>or=50 years. Compared to the ECD donor group, the DKT donor group was older (mean age 64.6+/-7.7 years vs. 59.9+/-6.2 years) and consisted of more African Americans (13.1% vs. 9.9%), and more diabetic donors (16.3% vs. 10.4%; P<0.001). Mean cold ischemic time was longer in DKT (22.2+/-9.7 hr), but rates of delayed graft function were lower (29.3%) compared to ECD transplants (33.6%, P=0.03). Three-year overall graft survival was 79.8% for DKT and 78.3% for ECD transplants. DKT were infrequent and had outcomes comparable to ECD transplants, despite the use of organs from higher risk donors. With a more upfront approach to DKT by offering this option to patients at the time of wait-listing as part of an ECD algorithm, we may be able to further optimize outcomes of DKT and minimize discard of potential organs.

  11. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory : determination of organochlorine pesticides and polychlorinated biphenyls in bottom and suspended sediment by gas chromatography with electron-capture detection

    USGS Publications Warehouse

    Noriega, Mary C.; Wydoski, Duane S.; Foreman, William T.

    2004-01-01

    A method applicable for the determination of 19 organochlorine (OC) pesticides, including total toxaphene as a complex mixture, and 3 polychlorinated biphenyl (PCB) mixtures as Aroclor equivalents--Aroclor 1016/1242, 1254, and 1260--in soil, aquatic bottom sediment, and suspended sediment is described. Method performance data are presented. The solvent system is designed to extract simultaneously selected OC pesticides and PCBs from the same sample matrix. The compounds are extracted by conventional Soxhlet extraction with dichloromethane, followed by partial isolation using gel permeation chromatography (GPC) to remove inorganic sulfur and large naturally present molecules from the sediment extract. The aliquot of extract collected from the GPC for OCs (OC pesticides and PCBs) is split into two sample fractions by alumina/silica combined-column chromatography, followed by Florisil adsorption chromatography to remove interfering compounds in the second fraction. The OC fractions are analyzed by dual capillary-column gas chromatography with electron-capture detection (GC/ECD). This report is limited to the determination of selected OC pesticides and PCBs by GC/ECD using this method. Interim reporting levels (IRLs) have been set at 0.400 to 3.12 micrograms per kilogram for 18 individual OC pesticides, 200 micrograms per kilogram for toxaphene, and 4.04 to 4.68 micrograms per kilogram for the PCBs, based on a sample size of 25-gram equivalent dry weight. These reporting levels may change following additional determinations of method detection limits.

  12. Structural Determinants Underlying Constitutive Dimerization of Unoccupied Human Follitropin Receptors

    PubMed Central

    Guan, Rongbin; Wu, Xueqing; Feng, Xiuyan; Zhang, Meilin; Hébert, Terence E.; Segaloff, Deborah L.

    2009-01-01

    The human follitropin receptor (hFSHR) is a G protein-coupled receptor (GPCR) central to reproductive physiology that is composed of an extracellular domain (ECD) fused to a serpentine region. Using bioluminescence resonance energy transfer (BRET) in living cells, we show that hFSHR dimers form constitutively during their biosynthesis. Mutations in TM1 and TM4 had no effect on hFSHR dimerization, alone or when combined with mutation of Tyr110 in the ECD, a residue predicted to mediate dimerization of the soluble hormone-binding portion of the ECD complexed with FSH (Q. Fan and W. Hendrickson, Nature 433:269–277, 2005). Expressed individually, the serpentine region and a membrane-anchored form of the hFSHR ECD each exhibited homodimerization, suggesting that both domains contribute to dimerization of the full-length receptor. However, even in the context of only the membrane-anchored ECD, mutation of Tyr110 to alanine did not inhibit dimerization. The full-length hFSHR and the membrane-anchored ECD were then each engineered to introduce a consensus site for N-linked glycosylation at residue 110. Despite experimental validation of the presence of carbohydrate on residue 110, we failed to observe disruption of dimerization of either the full-length hFSHR or membrane-anchored ECD containing the inserted glycan wedge. Taken altogether, our data suggest that both the serpentine region and the ECD contribute to hFSHR dimerization and that the dimerization interface of the unoccupied hFSHR does not involve Tyr110 of the ECD. PMID:19800402

  13. Generation of global political priority for early childhood development: the challenges of framing and governance.

    PubMed

    Shawar, Yusra Ribhi; Shiffman, Jeremy

    2017-01-07

    Despite progress, early childhood development (ECD) remains a neglected issue, particularly in resource-poor countries. We analyse the challenges and opportunities that ECD proponents face in advancing global priority for the issue. We triangulated among several data sources, including 19 semi-structured interviews with individuals involved in global ECD leadership, practice, and advocacy, as well as peer-reviewed research, organisation reports, and grey literature. We undertook a thematic analysis of the collected data, drawing on social science scholarship on collective action and a policy framework that elucidates why some global initiatives are more successful in generating political priority than others. The analysis indicates that the ECD community faces two primary challenges in advancing global political priority. The first pertains to framing: generation of internal consensus on the definition of the problem and solutions, agreement that could facilitate the discovery of a public positioning of the issue that could generate political support. The second concerns governance: building of effective institutions to achieve collective goals. However, there are multiple opportunities to advance political priority for ECD, including an increasingly favourable political environment, advances in ECD metrics, and the existence of compelling arguments for investment in ECD. To advance global priority for ECD, proponents will need to surmount the framing and governance challenges and leverage these opportunities. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Sleep Loss and the Inflammatory Response in Mice Under Chronic Environmental Circadian Disruption

    PubMed Central

    Castanon-Cervantes, Oscar; Natarajan, Divya; Delisser, Patrick; Davidson, Alec J.; Paul, Ketema N.

    2013-01-01

    Shift work and trans-time zone travel lead to insufficient sleep and numerous pathologies. Here, we examined sleep/wake dynamics during chronic exposure to environmental circadian disruption (ECD), and if chronic partial sleep loss associated with ECD influences the induction of shift-related inflammatory disorder. Sleep and wakefulness were telemetrically recorded across three months of ECD, in which the dark-phase of a light-dark cycle was advanced weekly by 6 h. A three month regimen of ECD caused a temporary reorganization of sleep (NREM and REM) and wake processes across each week, resulting in an approximately 10% net loss of sleep each week relative to baseline levels. A separate group of mice were subjected to ECD or a regimen of imposed wakefulness (IW) aimed to mimic sleep amounts under ECD for one month. Fos-immunoreactivity (IR) was quantified in sleep-wake regulatory areas: the nucleus accumbens (NAc), basal forebrain (BF), and medial preoptic area (MnPO). To assess the inflammatory response, trunk blood was treated with lipopolysaccharide (LPS) and subsequent release of IL-6 was measured. Fos-IR was greatest in the NAc, BF, and MnPO of mice subjected to IW. The inflammatory response to LPS was elevated in mice subjected to ECD, but not mice subjected to IW. Thus, the net sleep loss that occurs under ECD is not associated with a pathological immune response. PMID:23696854

  15. Histological features of localized scleroderma 'en coup de sabre': a study of 16 cases.

    PubMed

    Taniguchi, T; Asano, Y; Tamaki, Z; Akamata, K; Aozasa, N; Noda, S; Takahashi, T; Ichimura, Y; Toyama, T; Sugita, M; Sumida, H; Kuwano, Y; Miyazaki, M; Yanaba, K; Sato, S

    2014-12-01

    Early lesions of localized scleroderma are histologically characterized by perivascular lymphocytic infiltrate in the reticular dermis and swollen endothelial cells. However, there have been few information regarding histological features other than these findings in localized scleroderma. Since en coup de sabre (ECDS) is a certain subset of localized scleroderma with a relatively uniform clinical manifestation, we focused on this disease subset and evaluated its histopathological features. A total of 16 patients with ECDS were retrospectively evaluated on the basis of clinical and histological findings. Regardless of clinical manifestations, vacuolar degeneration was found in all of the ECDS patients. Importantly, keratinocyte necroses were restricted to early and active ECDS lesions. In early ECDS patients (disease duration of <3 years), moderate to severe perivascular and/or periappendageal lymphocytic infiltrate and vacuolar changes in follicular epithelium were more prominent, whereas epidermal atrophy was less frequently observed, than in late ECDS patients (disease duration of ≥6 years). Vacuolar degeneration at the dermoepidermal junction is a common histological feature in ECDS and perivascular and/or periappendageal lymphocytic infiltrate and vacuolar degeneration of follicular epithelium are characteristic especially in early ECDS, further supporting a canonical idea that the elimination of mutated epidermal cells by immune surveillance contributes to tissue damage and resultant fibrosis in localized scleroderma. © 2013 European Academy of Dermatology and Venereology.

  16. Impact of a child stimulation intervention on early child development in rural Peru: a cluster randomised trial using a reciprocal control design

    PubMed Central

    Hartinger, Stella Maria; Lanata, Claudio Franco; Hattendorf, Jan; Wolf, Jennyfer; Gil, Ana Isabel; Obando, Mariela Ortiz; Noblega, Magaly; Verastegui, Hector; Mäusezahl, Daniel

    2017-01-01

    Objective Stimulation in early childhood can alleviate adverse effects of poverty. In a community-randomised trial, we implemented 2 home-based interventions, each serving as an attention control for the other. One group received an integrated household intervention package (IHIP), whereas the other group received an early child development (ECD) intervention. The primary objective of the study was to evaluate the effect of IHIP on diarrhoea and respiratory infections, the details of which are described elsewhere. Here, we present the impact of the ECD intervention on early childhood development indicators. Methods In this non-blinded community-randomised trial, an ECD intervention, adapted from the Peruvian government's National Wawa Wasi ECD programme, was implemented in 25 rural Peruvian Andean communities. We enrolled 534 children aged 6–35 months, from 50 communities randomised 1:1 into ECD and IHIP communities. In ECD communities, trained fieldworkers instructed mothers every 3 weeks over the 12 months study, to stimulate and interact with their children and to use standard programme toys. IHIP communities received an improved stove and hygiene promotion. Using a nationally validated ECD evaluation instrument, all children were assessed at baseline and 12 months later for overall performance on age-specific developmental milestones which fall into 7 developmental domains. Findings At baseline, ECD-group and IHIP-group children performed similarly in all domains. After 12 months, data from 258 ECD-group and 251 IHIP-group children could be analysed. The proportion of children scoring above the mean in their specific age group was significantly higher in the ECD group in all domains (range: 12–23%-points higher than IHIP group). We observed the biggest difference in fine motor skills (62% vs 39% scores above the mean, OR: 2.6, 95% CI 1.7 to 3.9). Conclusions The home-based ECD intervention effectively improved child development overall across domains and separately by investigated domain. Home-based strategies could be a promising component of poverty alleviation programmes seeking to improve developmental outcomes among rural Peruvian children. Trial registration number ISRCTN28191222; results. PMID:27612978

  17. Objective, domain-specific HER2 measurement in uterine and ovarian serous carcinomas and its clinical significance.

    PubMed

    Carvajal-Hausdorf, Daniel E; Schalper, Kurt A; Bai, Yalai; Black, Jonathan; Santin, Alessandro D; Rimm, David L

    2017-04-01

    HER2 overexpression/amplification is identified in up to 40% of uterine serous carcinomas (USC) and 10% of ovarian serous carcinomas (OSC). However, clinical trials using various HER2-targeted agents failed to show significant responses. FDA-approved HER2 assays target only the protein's intracellular domain (ICD) and not the extracellular domain (ECD). Previous quantitative studies in breast cancer by our group have shown that ICD of HER2 is expressed in some cases that do not express the HER2 ECD. We measured HER2 ICD and ECD in USC and OSC samples, and determined their relationship with clinico-pathologic characteristics and survival. We measured HER2 ICD and ECD levels in 2 cohorts of USC and OSC comprising 102 and 175 patients, respectively. HER2 antibodies targeting ICD (CB11) and ECD (SP3) were validated and standardized using the AQUA® method of quantitative immunofluorescence (QIF) and a previously reported HER2 standardization tissue microarray (TMA). Objective, population-based cut-points were used to stratify patients according to HER2 ICD/ECD status. In USC, 8% of patients with high HER2 ICD had low ECD levels (6/75 patients). In OSC, 42% of patients with high HER2 ICD had low ECD levels (29/69 patients). HER2 ICD/ECD status in USC and OSC was not significantly associated with major clinico-pathological features or survival. Using objective, domain-specific HER2 measurement, 8% of USC and 42% of OSC patients with high HER2 ICD levels do not show uniform overexpression of the ECD. This may be related to the presence of p95 HER2, an oncogenic fragment generated by full protein cleavage or alternative initiation of translation. These observations raise the possibility that USC/OSCs expressing low ECD despite being HER2-positive by ICD measurement, may benefit from therapies directed against the intracellular domain (e.g. lapatinib or afatinib) alone or in combination with extracellular domain-directed drugs (e.g. trastuzumab, pertuzumab, T-DM1). Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  18. Measuring θ13 in the Double Chooz experiment

    NASA Astrophysics Data System (ADS)

    Crum, Keith

    2013-04-01

    Double Chooz measures θ13 by searching for the disappearance of reactor electron antineutrinos (νe) interacting via inverse beta decay (IBD) in a liquid scintillator-based detector. The signature of IBD is the coincidence of positron annihilation followed by the capture of a neutron. Although Double Chooz was primarily designed to detect νe by searching for neutron capture on gadolinium, we can also search for neutron capture on hydrogen. We developed separate analyses for neutron capture on hydrogen and gadolinium as the two elements have different capture energies, capture lifetimes, and spatial distributions within our detector.

  19. Decision Making by Young Transplant Surgeons Regarding Expanded-Criteria Donors With Acute Kidney Injury or Allocation Failure.

    PubMed

    Jung, D; Park, S; Kim, S H; Eom, M; Kim, J S; Yang, J W; Han, B G; Choi, S O

    2016-04-01

    The utilization of expanded-criteria donors (ECDs) has increased to overcome donor shortages. Unfortunately, the discard rate has also increased, especially in ECDs with acute kidney injury (AKI). We evaluated the outcomes of kidney transplantation in ECDs and standard-criteria donors (SCDs) with and without AKI. We reviewed the medical records of patients who underwent kidney transplantation. We used the AKI definition published by the Kidney Disease: Improving Global Outcomes group and reviewed the demographic characteristics of donors and recipients. We analyzed transplantation outcomes. Twenty-seven patients underwent kidney transplantation from ECDs with AKI (n = 6) or without AKI (n = 5) and SCDs with AKI (n = 6) or without AKI (n = 10). Initial creatinine and estimated glomerular filtration rate (eGFR) were not significantly different between the groups. The incidence of delayed graft function was highest in ECDs with AKI (n = 3; 36.4%), but this was not a significantly difference. There was no difference in the last creatinine and eGFR in ECDs with AKI (1.32 mg/dL, 58.7 mL/min/1.73 m(2)), ECDs without AKI (1.67 mg/dL, 44.2 mL/min/1.73 m(2)), SCDs with AKI (0.94 mg/dL, 81.5 mL/min/1.73 m(2)) and SCDs without AKI (0.97 mg/dL, 81.8 mL/min/1.73 m(2)). As the donor pool is extended to ECDs, young transplant surgeons may increasingly face decisions regarding ECDs with AKI or allocation failure. There is no consensus regarding discard criteria. However, if the donor showed initially normal creatinine levels or if dual-kidney transplantation can be performed, young transplant surgeons should not hesitate to use ECDs with AKI or allocation failure. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Microchip Capillary Electrophoresis with Electrochemical Detection for Monitoring Environmental Pollutants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Gang; Lin, Yuehe; Wang, Joseph

    2006-01-15

    This invited paper reviews recent advances and the key strategies in microchip capillary electrophoresis (CE) with electrochemical detection (ECD) for separating and detecting a variety of environmental pollutants. The subjects covered include the fabrication of microfluidic chips, sample pretreatments, ECD, typical applications of microchip CE with ECD in environmental analysis, and future prospects. It is expected that microchip CE-ECD will become a powerful tool in the environmental field and will lead to the creation of truly portable devices.

  1. Study of Small Ligands Which Bind Specifically to Breast Cancer Cells

    DTIC Science & Technology

    1997-09-01

    Sepharose conjugated to three different lectins: ConA, wheat germ and lentil,. Each lectin bound many proteins in both the ECD-AP sup and the control 3T3 sup...control Lanes 13-14: Wheat germ ECD-AP Lanes 15-16: Wheat germ 3T3 control Odd lanes were eluted with a low sugar concentration; even lanes were...ECD-AP post incubation with lentil-Sepharose Lane 6: Protein remaining in pp ECD-AP post incubation with wheat germ -Sepharose Lane 8: Protein

  2. Simultaneous measurement of (n,{gamma}) and (n,fission) cross sections with the DANCE 4{pi} BaF2 array

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bredeweg, T. A.; Fowler, M. M.; Bond, E. M.

    2006-03-13

    Neutron capture cross section measurements on many of the actinides are complicated by low-energy neutron-induced fission, which competes with neutron capture to varying degrees depending on the nuclide of interest. Measurements of neutron capture on 235U using the Detector for Advanced Neutron Capture Experiments (DANCE) have shown that we can partially resolve capture from fission events based on total photon calorimetry (i.e. total {gamma}-ray energy and {gamma}-ray multiplicity per event). The addition of a fission-tagging detector to the DANCE array will greatly improve our ability to separate these two competing processes so that improved neutron capture and (n,{gamma})/(n,fission) cross sectionmore » ratio measurements can be obtained. The addition of a fission-tagging detector to the DANCE array will also provide a means to study several important issues associated with neutron-induced fission, including (n,fission) cross sections as a function of incident neutron energy, and total energy and multiplicity of prompt fission photons. We have focused on two detector designs with complementary capabilities, a parallel-plate avalanche counter and an array of solar cells.« less

  3. Preimplantation Kidney Biopsies of Extended Criteria Donors Have a Heavier Inflammatory Burden Than Kidneys From Standard Criteria Donors

    PubMed Central

    Mazeti-Felicio, Camila M.; Caldas, Heloisa C.; Fernandes-Charpiot, Ida M.M.; Dezotti, Camila Z.; Baptista, Maria A.S.F.; Abbud-Filho, Mario

    2017-01-01

    Background Donors after brain death develop a systemic proinflammatory state that may predispose the kidneys to injury after transplantation. Because it is not known whether this inflammatory environment similarly affects the kidneys from expanded criteria donor (ECD) and standard criteria donors (SCD), we sought to evaluate differences in the gene expression of inflammatory cytokines in preimplantation biopsies (PIBx) from ECD and SCD kidneys. Methods Cytokines gene expression was measured in 80 PIBx (SCD, 52; ECD, 28) and associated with donor variables. Results Normal histology and chronic histological lesions were not different between both types of kidneys. ECD kidneys showed significant increase in the transcripts of MCP-1, RANTES, TGF-β1, and IL-10 when compared with SCD. Kidneys presenting normal histology had similar inflammatory profile except by a higher expression of RANTES observed in ECD (P = 0.04). Interstitial fibrosis and tubular atrophy (interstitial fibrosis and tubular atrophy ≥ 1) were associated with higher expression of TGF-β1, RANTES, and IL-10 in ECD compared with SCD kidneys. Cold ischemia time of 24 hours or longer was significantly associated with upregulation of FOXP3, MCP-1, RANTES, and IL10, whereas longer duration of donor hospitalization significantly increased gene expression of all markers. High FOXP3 expression was also associated with lower level of serum creatinine at 1 year. Donor age was not associated with any of the transcripts studied. Conclusions PIBx of ECD exhibit a higher gene expression of inflammatory cytokines when compared with SCD kidneys. This molecular profile may be a specific ECD kidney response to brain death and may help to predict the posttransplant outcomes of ECD recipients. PMID:28706983

  4. Aromatic Cluster Sensor of Protein Folding: Near-UV Electronic Circular Dichroism Bands Assigned to Fold Compactness.

    PubMed

    Farkas, Viktor; Jákli, Imre; Tóth, Gábor K; Perczel, András

    2016-09-19

    Both far- and near-UV electronic circular dichroism (ECD) spectra have bands sensitive to thermal unfolding of Trp and Tyr residues containing proteins. Beside spectral changes at 222 nm reporting secondary structural variations (far-UV range), L b bands (near-UV range) are applicable as 3D-fold sensors of protein's core structure. In this study we show that both L b (Tyr) and L b (Trp) ECD bands could be used as sensors of fold compactness. ECD is a relative method and thus requires NMR referencing and cross-validation, also provided here. The ensemble of 204 ECD spectra of Trp-cage miniproteins is analysed as a training set for "calibrating" Trp↔Tyr folded systems of known NMR structure. While in the far-UV ECD spectra changes are linear as a function of the temperature, near-UV ECD data indicate a non-linear and thus, cooperative unfolding mechanism of these proteins. Ensemble of ECD spectra deconvoluted gives both conformational weights and insight to a protein folding↔unfolding mechanism. We found that the L b 293 band is reporting on the 3D-structure compactness. In addition, the pure near-UV ECD spectrum of the unfolded state is described here for the first time. Thus, ECD folding information now validated can be applied with confidence in a large thermal window (5≤T≤85 °C) compared to NMR for studying the unfolding of Trp↔Tyr residue pairs. In conclusion, folding propensities of important proteins (RNA polymerase II, ubiquitin protein ligase, tryptase-inhibitor etc.) can now be analysed with higher confidence. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Her2/neu extracellular domain shedding in uterine serous carcinoma: implications for immunotherapy with trastuzumab.

    PubMed

    Todeschini, P; Cocco, E; Bellone, S; Varughese, J; Lin, K; Carrara, L; Guzzo, F; Buza, N; Hui, P; Silasi, D-A; Ratner, E; Azodi, M; Schwartz, P E; Rutherford, T J; Pecorelli, S; Santin, A D

    2011-10-11

    We evaluated shedding of epidermal growth factor type II receptor (Her2/neu) extracellular domain (ECD) in primary uterine serous carcinoma (USC) cell lines and in the serum of USC patients and its biological effects in experiments of trastuzumab-induced cytotoxicity in vitro. Her2/neu expression was evaluated by immunohistochemistry (IHC), real-time PCR and flow cytometry, while c-erbB2 gene amplification was assessed using fluorescent in situ hybridisation (FISH). Her2/neu ECD levels in the supernatants of USC cell lines and in the serum of 38 USC patients and 19 controls were tested using ELISA. The biologic effect of Her2/neu ECD on trastuzumab-induced antibody-dependent cell-mediated cytotoxicity (ADCC) was evaluated in 5-h chromium-release assays. Five out of ten USC cell lines overexpressed Her2/neu by IHC and showed amplification of the c-erbB2 gene. High levels of Her2/neu ECD were found in supernatants of all FISH-positive tumours. In contrast, FISH-negative USC was negative for Her2/neu ECD shedding. Serum Her2/neu ECD levels in patients harbouring 3+Her2/neu tumours were higher than those found in healthy women (P=0.02) or USC patients with 2+ or 1+/negative Her2/neu expression (P=0.02). In cytotoxicity experiments, trastuzumab-mediated ADCC was significantly decreased by the addition of Her2/neu ECD-containing supernatants (P=0.01). FISH-positive c-erbB2 USC cell lines shed high levels of Her2/neu ECD. High levels of Her2/neu ECD in USC patients may reduce trastuzumab-mediated ADCC in vitro and potentially neutralise its therapeutic effect in vivo.

  6. Neutron capture reactions at DANCE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bredeweg, T. A.

    2008-05-12

    The Detector for Advanced Neutron Capture Experiments (DANCE) is a 4{pi} BaF{sub 2} array consisting of 160 active detector elements. The primary purpose of the array is to perform neutron capture cross section measurements on small (> or approx.100 {mu}g) and/or radioactive (< or approx. 100 mCi) species. The measurements made possible with this array will be useful in answering outstanding questions in the areas of national security, threat reduction, nuclear astrophysics, advanced reactor design and accelerator transmutation of waste. Since the commissioning of DANCE we have performed neutron capture cross section measurements on a wide array of medium tomore » heavy mass nuclides. Measurements to date include neutron capture cross sections on {sup 241,243}Am, neutron capture and neutron-induced fission cross sections and capture-to-fission ratio ({alpha} = {sigma}{sub {gamma}}/{sigma}{sub f}) for {sup 235}U using a new fission-tagging detector as well as neutron capture cross sections for several astrophysics branch-point nuclei. Results from several of these measurements will be presented along with a discussion of additional physics information that can be extracted from the DANCE data.« less

  7. Designing Real-time Decision Support for Trauma Resuscitations

    PubMed Central

    Yadav, Kabir; Chamberlain, James M.; Lewis, Vicki R.; Abts, Natalie; Chawla, Shawn; Hernandez, Angie; Johnson, Justin; Tuveson, Genevieve; Burd, Randall S.

    2016-01-01

    Background Use of electronic clinical decision support (eCDS) has been recommended to improve implementation of clinical decision rules. Many eCDS tools, however, are designed and implemented without taking into account the context in which clinical work is performed. Implementation of the pediatric traumatic brain injury (TBI) clinical decision rule at one Level I pediatric emergency department includes an electronic questionnaire triggered when ordering a head computed tomography using computerized physician order entry (CPOE). Providers use this CPOE tool in less than 20% of trauma resuscitation cases. A human factors engineering approach could identify the implementation barriers that are limiting the use of this tool. Objectives The objective was to design a pediatric TBI eCDS tool for trauma resuscitation using a human factors approach. The hypothesis was that clinical experts will rate a usability-enhanced eCDS tool better than the existing CPOE tool for user interface design and suitability for clinical use. Methods This mixed-methods study followed usability evaluation principles. Pediatric emergency physicians were surveyed to identify barriers to using the existing eCDS tool. Using standard trauma resuscitation protocols, a hierarchical task analysis of pediatric TBI evaluation was developed. Five clinical experts, all board-certified pediatric emergency medicine faculty members, then iteratively modified the hierarchical task analysis until reaching consensus. The software team developed a prototype eCDS display using the hierarchical task analysis. Three human factors engineers provided feedback on the prototype through a heuristic evaluation, and the software team refined the eCDS tool using a rapid prototyping process. The eCDS tool then underwent iterative usability evaluations by the five clinical experts using video review of 50 trauma resuscitation cases. A final eCDS tool was created based on their feedback, with content analysis of the evaluations performed to ensure all concerns were identified and addressed. Results Among 26 EPs (76% response rate), the main barriers to using the existing tool were that the information displayed is redundant and does not fit clinical workflow. After the prototype eCDS tool was developed based on the trauma resuscitation hierarchical task analysis, the human factors engineers rated it to be better than the CPOE tool for nine of 10 standard user interface design heuristics on a three-point scale. The eCDS tool was also rated better for clinical use on the same scale, in 84% of 50 expert–video pairs, and was rated equivalent in the remainder. Clinical experts also rated barriers to use of the eCDS tool as being low. Conclusions An eCDS tool for diagnostic imaging designed using human factors engineering methods has improved perceived usability among pediatric emergency physicians. PMID:26300010

  8. HS-SPME determination of volatile carbonyl and carboxylic compounds in different matrices.

    PubMed

    Stashenko, Elena E; Mora, Amanda L; Cervantes, Martha E; Martínez, Jairo R

    2006-07-01

    Specific chromatographic methodologies are developed for the analysis of carboxylic acids (C(2)-C(6), benzoic) and aldehydes (C(2)-C(10)) of low molecular weight in diverse matrices, such as air, automotive exhaust gases, human breath, and aqueous matrices. For carboxylic acids, the method is based on their reaction with pentafluorobenzyl bromide in aqueous solution, followed by the separation and identification of the resultant pentafluorobenzyl esters by means of headspace (HS)-solid-phase microextraction (SPME) combined with gas chromatography (GC) and electron capture detection (ECD). Detection limits in the microg/m(3) range are reached, with relative standard deviation (RSD) less than 10% and linear response (R(2) > 0.99) over two orders of magnitude. The analytical methodology for aldehydes is based on SPME with simultaneous derivatization of the analytes on the fiber, by reaction with pentafluorophenylhydrazine. The derivatization reagent is previously deposited on the SPME fiber, which is then exposed to the gaseous matrix or the HS of the sample solution. The pentafluorophenyl hydrazones formed on the fiber are analyzed selectively by means of GC-ECD, with detection limits in the ng/m(3) range, RSD less than 10%, and linear response (R(2) > 0.99) over two orders of magnitude.

  9. Characterization of Tyrosine Nitration and Cysteine Nitrosylation Modifications by Metastable Atom-Activation Dissociation Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Cook, Shannon L.; Jackson, Glen P.

    2011-02-01

    The fragmentation behavior of nitrated and S-nitrosylated peptides were studied using collision induced dissociation (CID) and metastable atom-activated dissociation mass spectrometry (MAD-MS). Various charge states, such as 1+, 2+, 3+, 2-, of modified and unmodified peptides were exposed to a beam of high kinetic energy helium (He) metastable atoms resulting in extensive backbone fragmentation with significant retention of the post-translation modifications (PTMs). Whereas the high electron affinity of the nitrotyrosine moiety quenches radical chemistry and fragmentation in electron capture dissociation (ECD) and electron transfer dissociation (ETD), MAD does produce numerous backbone cleavages in the vicinity of the modification. Fragment ions of nitrosylated cysteine modifications typically exhibit more abundant neutral losses than nitrated tyrosine modifications because of the extremely labile nature of the nitrosylated cysteine residues. However, compared with CID, MAD produced between 66% and 86% more fragment ions, which preserved the labile -NO modification. MAD was also able to differentiate I/L residues in the modified peptides. MAD is able to induce radical ion chemistry even in the presence of strong radical traps and therefore offers unique advantages to ECD, ETD, and CID for determination of PTMs such as nitrated and S-nitrosylated peptides.

  10. Dissecting the dynamic conformations of the metamorphic protein lymphotactin.

    PubMed

    Harvey, Sophie R; Porrini, Massimiliano; Konijnenberg, Albert; Clarke, David J; Tyler, Robert C; Langridge-Smith, Patrick R R; MacPhee, Cait E; Volkman, Brian F; Barran, Perdita E

    2014-10-30

    A mass spectrometer provides an ideal laboratory to probe the structure and stability of isolated protein ions. Interrogation of each discrete mass/charge-separated species enables the determination of the intrinsic stability of a protein fold, gaining snapshots of unfolding pathways. In solution, the metamorphic protein lymphotactin (Ltn) exists in equilibrium between two distinct conformations, a monomeric (Ltn10) and a dimeric (Ltn40) fold. Here, we use electron capture dissociation (ECD) and drift tube ion mobility-mass spectrometry (DT IM-MS) to analyze both forms and use molecular dynamics (MD) to consider how the solution fold alters in a solvent-free environment. DT IM-MS reveals significant conformational flexibility for the monomer, while the dimer appears more conformationally restricted. These findings are supported by MD calculations, which reveal how salt bridges stabilize the conformers in vacuo. Following ECD experiments, a distinctive fragmentation pattern is obtained for both the monomer and dimer. Monomer fragmentation becomes more pronounced with increasing charge state especially in the disordered regions and C-terminal α-helix in the solution fold. Lower levels of fragmentation are seen in the β-sheet regions and in regions that contain salt bridges, identified by MD simulations. The lowest charge state of the dimer for which we obtain ECD data ([D+9H](9+)) exhibits extensive fragmentation with no relationship to the solution fold and has a smaller collision cross section (CCS) than charge states 10-13+, suggesting a "collapsed" encounter complex. Other charge states of the dimer, as for the monomer, are resistant to fragmentation in regions of β-sheets in the solution fold. This study provides evidence for preservation and loss of global fold and secondary structural elements, providing a tantalizing glimpse into the power of the emerging field of native top-down mass spectrometry.

  11. Rapid determination of residues of pesticides in honey by µGC-ECD and GC-MS/MS: Method validation and estimation of measurement uncertainty according to document No. SANCO/12571/2013.

    PubMed

    Paoloni, Angela; Alunni, Sabrina; Pelliccia, Alessandro; Pecorelli, Ivan

    2016-01-01

    A simple and straightforward method for simultaneous determination of residues of 13 pesticides in honey samples (acrinathrin, bifenthrin, bromopropylate, cyhalothrin-lambda, cypermethrin, chlorfenvinphos, chlorpyrifos, coumaphos, deltamethrin, fluvalinate-tau, malathion, permethrin and tetradifon) from different pesticide classes has been developed and validated. The analytical method provides dissolution of honey in water and an extraction of pesticide residues by n-Hexane followed by clean-up on a Florisil SPE column. The extract was evaporated and taken up by a solution of an injection internal standard (I-IS), ethion, and finally analyzed by capillary gas chromatography with electron capture detection (GC-µECD). Identification for qualitative purpose was conducted by gas chromatography with triple quadrupole mass spectrometer (GC-MS/MS). A matrix-matched calibration curve was performed for quantitative purposes by plotting the area ratio (analyte/I-IS) against concentration using a GC-µECD instrument. According to document No. SANCO/12571/2013, the method was validated by testing the following parameters: linearity, matrix effect, specificity, precision, trueness (bias) and measurement uncertainty. The analytical process was validated analyzing blank honey samples spiked at levels equal to and greater than 0.010 mg/kg (limit of quantification). All parameters were satisfactorily compared with the values established by document No. SANCO/12571/2013. The analytical performance was verified by participating in eight multi-residue proficiency tests organized by BIPEA, obtaining satisfactory z-scores in all 70 determinations. Measurement uncertainty was estimated according to the top-down approaches described in Appendix C of the SANCO document using the within-laboratory reproducibility relative standard deviation combined with laboratory bias using the proficiency test data.

  12. Revealing Ligand Binding Sites and Quantifying Subunit Variants of Noncovalent Protein Complexes in a Single Native Top-Down FTICR MS Experiment

    NASA Astrophysics Data System (ADS)

    Li, Huilin; Wongkongkathep, Piriya; Van Orden, Steve L.; Ogorzalek Loo, Rachel R.; Loo, Joseph A.

    2014-12-01

    "Native" mass spectrometry (MS) has been proven to be increasingly useful for structural biology studies of macromolecular assemblies. Using horse liver alcohol dehydrogenase (hADH) and yeast alcohol dehydrogenase (yADH) as examples, we demonstrate that rich information can be obtained in a single native top-down MS experiment using Fourier transform ion cyclotron mass spectrometry (FTICR MS). Beyond measuring the molecular weights of the protein complexes, isotopic mass resolution was achieved for yeast ADH tetramer (147 kDa) with an average resolving power of 412,700 at m/z 5466 in absorption mode, and the mass reflects that each subunit binds to two zinc atoms. The N-terminal 89 amino acid residues were sequenced in a top-down electron capture dissociation (ECD) experiment, along with the identifications of the zinc binding site at Cys46 and a point mutation (V58T). With the combination of various activation/dissociation techniques, including ECD, in-source dissociation (ISD), collisionally activated dissociation (CAD), and infrared multiphoton dissociation (IRMPD), 40% of the yADH sequence was derived directly from the native tetramer complex. For hADH, native top-down ECD-MS shows that both E and S subunits are present in the hADH sample, with a relative ratio of 4:1. Native top-down ISD of the hADH dimer shows that each subunit (E and S chains) binds not only to two zinc atoms, but also the NAD/NADH ligand, with a higher NAD/NADH binding preference for the S chain relative to the E chain. In total, 32% sequence coverage was achieved for both E and S chains.

  13. New measurement of θ 13 via neutron capture on hydrogen at Daya Bay

    DOE PAGES

    F. P. An

    2016-04-21

    This article reports an improved independent measurement of neutrino mixing angle θ 13 at the Daya Bay Reactor Neutrino Experiment. Electron antineutrinos were identified by inverse β-decays with the emitted neutron captured by hydrogen, yielding a data set with principally distinct uncertainties from that with neutrons captured by gadolinium. With the final two of eight antineutrino detectors installed, this study used 621 days of data including the previously reported 217-day data set with six detectors. The dominant statistical uncertainty was reduced by 49%. Intensive studies of the cosmogenic muon-induced 9Li and fast neutron backgrounds and the neutron-capture energy selection efficiency,more » resulted in a reduction of the systematic uncertainty by 26%. The deficit in the detected number of antineutrinos at the far detectors relative to the expected number based on the near detectors yielded sin 22θ 13 = 0.071 ± 0.011 in the three-neutrino-oscillation framework. As a result, the combination of this result with the gadolinium-capture result is also reported.« less

  14. Prevention of glucocorticoid induced bone changes with beta-ecdysone

    PubMed Central

    Dai, Weiwei; Jiang, Li; Lay, Yu-An Evan; Chen, Haiyan; Jin, Guoqin; Zhang, Hongliang; Kot, Alex; Ritchie, Robert O.; Lane, Nancy E.; Yao, Wei

    2015-01-01

    Beta-ecdysone (βEcd) is a phytoecdysteroid found in the dry roots and seeds of the asteraceae and achyranthes plants, and is reported to increase osteogenesis in vitro. Since glucocorticoid (GCs) excess is associated with a decrease in bone formation, the purpose of this study was to determine if treatment with βEcd could prevent GC-induced osteoporosis. Two-month-old male Swiss-Webster mice (n=8-10/group) were randomized to either placebo or slow release prednisolone pellets (3.3mg/kg/d) and treated with vehicle control or βEcd (0.5mg/kg/d) for 21 days. GC treatment inhibited age-dependent trabecular gain and cortical bone expansion and this was accompanied by a 30-50% lower bone formation rate (BFR) at both the endosteal and periosteal surfaces. Mice treated with only βEcd significantly increased bone formation on endosteal and periosteal bone surfaces, and increased cortical bone mass were their controls to compare to GC alone. Concurrent treatment of βEcd and GC completely prevented the GC-induced reduction in BFR, trabecular bone volume and partially prevented cortical bone loss. In vitro studies determined that βEcd prevented the GC increase in autophagy of the bone marrow stromal cells as well as in whole bone. In summary, βEcd prevented GC induced changes in bone formation, bone cell viability and bone mass. Additional studies are warranted of βEcd for the treatment of GC induced bone loss. PMID:25585248

  15. Prevention of glucocorticoid induced bone changes with beta-ecdysone.

    PubMed

    Dai, Weiwei; Jiang, Li; Lay, Yu-An Evan; Chen, Haiyan; Jin, Guoqin; Zhang, Hongliang; Kot, Alexander; Ritchie, Robert O; Lane, Nancy E; Yao, Wei

    2015-05-01

    Beta-ecdysone (βEcd) is a phytoecdysteroid found in the dry roots and seeds of the asteraceae and achyranthes plants, and is reported to increase osteogenesis in vitro. Since glucocorticoid (GC) excess is associated with a decrease in bone formation, the purpose of this study was to determine if treatment with βEcd could prevent GC-induced osteoporosis. Two-month-old male Swiss-Webster mice (n=8-10/group) were randomized to either placebo or slow release prednisolone pellets (3.3mg/kg/day) and treated with vehicle control or βEcd (0.5mg/kg/day) for 21days. GC treatment inhibited age-dependent trabecular gain and cortical bone expansion and this was accompanied by a 30-50% lower bone formation rate (BFR) at both the endosteal and periosteal surfaces. Mice treated with only βEcd significantly increased bone formation on the endosteal and periosteal bone surfaces, and increased cortical bone mass were their controls to compare to GC alone. Concurrent treatment of βEcd and GC completely prevented the GC-induced reduction in BFR, trabecular bone volume and partially prevented cortical bone loss. In vitro studies determined that βEcd prevented the GC increase in autophagy of the bone marrow stromal cells as well as in whole bone. In summary, βEcd prevented GC induced changes in bone formation, bone cell viability and bone mass. Additional studies are warranted of βEcd for the treatment of GC induced bone loss. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Contents of lecithin and choline in crude drugs.

    PubMed

    Yamasaki, K; Kikuoka, M; Nishi, H; Kokusenya, Y; Miyamoto, T; Matsuo, M; Sato, T

    1994-01-01

    The determination of lecithin and choline in crude drugs was established by a combination of high performance liquid chromatography (HPLC) with electrochemical detector (ECD) and enzyme reaction. Lecithin in crude drugs extracted with a mixture of chloroform-methanol (2:1) at room temperature was hydrolyzed by phospholipase D. The hydrolyzate was injected to HPLC, and choline was separated from impurities by reverse phase column. The choline was converted to betaine and hydrogen peroxide by passing through column packed with immobilized choline oxidase. This hydrogen peroxide was detected by ECD. The peak area of hydrogen peroxide derived from lecithin was proportional to the concentration of lecithin from 0.10 to 1.52 microgram/ml. Choline in crude drugs was extracted with ethanol under reflux and determined under the same HPLC conditions as lecithin. The peak area of hydrogen peroxide derived from choline was proportional to the concentration of choline from 0.01 to 0.45 microgram/ml. The contents of lecithin and choline in 31 kinds of crude drugs were determined by these established methods. The results showed that Cervi Parvum Cornu, Kokurozin, Foenigraeci Semen and Psoraleae Semen contained more lecithin than other crude drugs, while Angelicae Radix, Foenigraeci Semen, Psoraleae Semen, and especially Hippocampus were found to contain more choline than other crude drugs.

  17. A Monoclonal–Monoclonal Antibody Based Capture ELISA for Abrin

    PubMed Central

    Tam, Christina C.; Cheng, Luisa W.; He, Xiaohua; Merrill, Paul; Hodge, David; Stanker, Larry H.

    2017-01-01

    Abrin, one of the most highly potent toxins in the world, is derived from the plant, Abrus precatorius. Because of its high toxicity, it poses potential bioterror risks. Therefore, a need exists for new reagents and technologies that would be able to rapidly detect abrin contamination as well as lead to new therapeutics. We report here a group of abrin-specific monoclonal antibodies (mAbs) that recognize abrin A-chain, intact A–B chain toxin, and agglutinin by Western blot. Additionally, these mAbs were evaluated for their ability to serve as capture antibodies for a sandwich (capture) ELISA. All possible capture–detector pairs were evaluated and the best antibody pair identified and optimized for a capture ELISA. The capture ELISA based on this capture–detector mAb pair had a limit of detection (L.O.D) of ≈1 ng/mL measured using three independent experiments. The assay did not reveal any false positives with extracts containing other potential ribosome-inactivating proteins (RIPs). Thus, this new capture ELISA uses mAbs for both capture and detection; has no cross-reactivity against other plant RIPs; and has a sensitivity comparable to other reported capture ELISAs using polyclonal antibodies as either capture or detector. PMID:29057799

  18. 78 FR 37150 - Airworthiness Directives; Eurocopter Deutschland GmbH (ECD) Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-20

    ... Deutschland GmbH (ECD) Helicopters AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of...): Eurocopter Deutschland GmbH (ECD): Docket No. FAA-2013-0519; Directorate Identifier 2010-SW-068-AD. (a... European Aviation Safety Agency AD No. 2010-0128, dated June 25, 2010. (h) Subject Joint Aircraft Service...

  19. 78 FR 52412 - Airworthiness Directives; Eurocopter Deutschland GmbH (ECD) Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-23

    ... Airworthiness Directives; Eurocopter Deutschland GmbH (ECD) Helicopters AGENCY: Federal Aviation Administration... new airworthiness directive (AD): 2013-16-20 Eurocopter Deutschland GmbH (ECD): Amendment 39-17558... the EASA AD at http://www.regulations.gov in Docket No. FAA-2013-0020. (h) Subject Joint Aircraft...

  20. Erdheim-Chester Disease Involving the Central Nervous System with the Unique Appearance of a Coated Vertebral Artery.

    PubMed

    Suzuki, Hime; Wanibuchi, Masahiko; Komatsu, Katsuya; Akiyama, Yukinori; Mikami, Takeshi; Sugita, Shintaro; Hasegawa, Tadashi; Kaya, Mitsunori; Takada, Kohichi; Mikuni, Nobuhiro

    2016-10-01

    Erdheim-Chester disease (ECD) is a rare non-Langerhans cell histiocytosis. It is characterized by multiple xanthogranulomatous masses throughout the body, predominantly in the tibia. One of the characteristic radiological findings of the lesions associated with ECD is a "coated artery," which is often observed in the aorta. Although approximately one-fourth of ECD cases involve the central nervous system (CNS), an intracranial-coated artery has only been reported in four cases. We report a case of ECD that involves the CNS and has the unique appearance of a coated vertebral artery (VA). These tumors entirely encase the bilateral VAs without stenosis and are attached to the dura. Cranial magnetic resonance imaging also showed multiple extra-axial tumors in the cavernous sinus, the frontal convexity, and the orbital cavity. Further investigation revealed additional extracranial lesions around the cervical carotid artery, at the bilateral tibia, and at the elbow joint. A biopsy of the cervical and tibial lesions confirmed ECD. Steroid therapy resulted in a month-long improvement of preoperative symptoms. However, the patient's condition gradually progressed and he died of pneumonia 1 year after ECD diagnosis. The encasement of the intracranial artery by the tumor without stenosis and the dural attachment suggest ECD, which requires whole body investigation.

  1. Erdheim-Chester Disease Involving the Central Nervous System with the Unique Appearance of a Coated Vertebral Artery

    PubMed Central

    Suzuki, Hime; Wanibuchi, Masahiko; Komatsu, Katsuya; Akiyama, Yukinori; Mikami, Takeshi; Sugita, Shintaro; Hasegawa, Tadashi; Kaya, Mitsunori; Takada, Kohichi; Mikuni, Nobuhiro

    2016-01-01

    Erdheim-Chester disease (ECD) is a rare non-Langerhans cell histiocytosis. It is characterized by multiple xanthogranulomatous masses throughout the body, predominantly in the tibia. One of the characteristic radiological findings of the lesions associated with ECD is a “coated artery,” which is often observed in the aorta. Although approximately one-fourth of ECD cases involve the central nervous system (CNS), an intracranial-coated artery has only been reported in four cases. We report a case of ECD that involves the CNS and has the unique appearance of a coated vertebral artery (VA). These tumors entirely encase the bilateral VAs without stenosis and are attached to the dura. Cranial magnetic resonance imaging also showed multiple extra-axial tumors in the cavernous sinus, the frontal convexity, and the orbital cavity. Further investigation revealed additional extracranial lesions around the cervical carotid artery, at the bilateral tibia, and at the elbow joint. A biopsy of the cervical and tibial lesions confirmed ECD. Steroid therapy resulted in a month-long improvement of preoperative symptoms. However, the patient’s condition gradually progressed and he died of pneumonia 1 year after ECD diagnosis. The encasement of the intracranial artery by the tumor without stenosis and the dural attachment suggest ECD, which requires whole body investigation. PMID:28664013

  2. Impact of a child stimulation intervention on early child development in rural Peru: a cluster randomised trial using a reciprocal control design.

    PubMed

    Hartinger, Stella Maria; Lanata, Claudio Franco; Hattendorf, Jan; Wolf, Jennyfer; Gil, Ana Isabel; Obando, Mariela Ortiz; Noblega, Magaly; Verastegui, Hector; Mäusezahl, Daniel

    2017-03-01

    Stimulation in early childhood can alleviate adverse effects of poverty. In a community-randomised trial, we implemented 2 home-based interventions, each serving as an attention control for the other. One group received an integrated household intervention package (IHIP), whereas the other group received an early child development (ECD) intervention. The primary objective of the study was to evaluate the effect of IHIP on diarrhoea and respiratory infections, the details of which are described elsewhere. Here, we present the impact of the ECD intervention on early childhood development indicators. In this non-blinded community-randomised trial, an ECD intervention, adapted from the Peruvian government's National Wawa Wasi ECD programme, was implemented in 25 rural Peruvian Andean communities. We enrolled 534 children aged 6-35 months, from 50 communities randomised 1:1 into ECD and IHIP communities. In ECD communities, trained fieldworkers instructed mothers every 3 weeks over the 12 months study, to stimulate and interact with their children and to use standard programme toys. IHIP communities received an improved stove and hygiene promotion. Using a nationally validated ECD evaluation instrument, all children were assessed at baseline and 12 months later for overall performance on age-specific developmental milestones which fall into 7 developmental domains. At baseline, ECD-group and IHIP-group children performed similarly in all domains. After 12 months, data from 258 ECD-group and 251 IHIP-group children could be analysed. The proportion of children scoring above the mean in their specific age group was significantly higher in the ECD group in all domains (range: 12-23%-points higher than IHIP group). We observed the biggest difference in fine motor skills (62% vs 39% scores above the mean, OR: 2.6, 95% CI 1.7 to 3.9). The home-based ECD intervention effectively improved child development overall across domains and separately by investigated domain. Home-based strategies could be a promising component of poverty alleviation programmes seeking to improve developmental outcomes among rural Peruvian children. ISRCTN28191222; results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  3. Impact of nitrate-enhanced leachate recirculation on gaseous releases from a landfill bioreactor cell

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tallec, G.; Bureau, C.; Peu, P.

    2009-07-15

    This study evaluates the impact of nitrate injection on a full scale landfill bioreactor through the monitoring of gaseous releases and particularly N{sub 2}O emissions. During several weeks, we monitored gas concentrations in the landfill gas collection system as well as surface gas releases with a series of seven static chambers. These devices were directly connected to a gas chromatograph coupled to a flame ionisation detector and an electron capture detector (GC-FID/ECD) placed directly on the field. Measurements were performed before, during and after recirculation of raw leachate and nitrate-enhanced leachate. Raw leachate recirculation did not have a significant effectmore » on the biogas concentrations (CO{sub 2}, CH{sub 4} and N{sub 2}O) in the gas extraction network. However, nitrate-enhanced leachate recirculation induced a marked increase of the N{sub 2}O concentrations in the gas collected from the recirculation trench (100-fold increase from 0.2 ppm to 23 ppm). In the common gas collection system however, this N{sub 2}O increase was no more detectable because of dilution by gas coming from other cells or ambient air intrusion. Surface releases through the temporary cover were characterized by a large spatial and temporal variability. One automated chamber gave limited standard errors over each experimental period for N{sub 2}O releases: 8.1 {+-} 0.16 mg m{sup -2} d{sup -1} (n = 384), 4.2 {+-} 0.14 mg m{sup -2} d{sup -1} (n = 132) and 1.9 {+-} 0.10 mg m{sup -2} d{sup -1} (n = 49), during, after raw leachate and nitrate-enhanced leachate recirculation, respectively. No clear correlation between N{sub 2}O gaseous surface releases and recirculation events were evidenced. Estimated N{sub 2}O fluxes remained in the lower range of what is reported in the literature for landfill covers, even after nitrate injection.« less

  4. Neutron capture and neutron-induced fission experiments on americium isotopes with DANCE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jandel, M.; Bredeweg, T. A.; Fowler, M. M.

    2009-01-28

    Neutron capture cross section data on Am isotopes were measured using the Detector for Advanced Neutron Capture Experiments (DANCE) at Los Alamos National Laboratory. The neutron capture cross section was determined for {sup 241}Am for neutron energies between thermal and 320 keV. Preliminary results were also obtained for {sup 243}Am for neutron energies between 10 eV and 250 keV. The results on concurrent neutron-induced fission and neutron-capture measurements on {sup 242m}Am will be presented where the fission events were actively triggered during the experiments. In these experiments, a Parallel-Plate Avalanche Counter (PPAC) detector that surrounds the target located in themore » center of the DANCE array was used as a fission-tagging detector to separate (n,{gamma}) events from (n,f) events. The first direct observation of neutron capture on {sup 242m}Am in the resonance region in between 2 and 9 eV of the neutron energy was obtained.« less

  5. Neutron capture and neutron-induced fission experiments on americium isotopes with DANCE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jandel, Marian

    2008-01-01

    Neutron capture cross section data on Am isotopes were measured using the Detector for Advanced Neutron Capture Experiments (DANCE) at Los Alamos National Laboratory. The neutron capture cross section was determined for {sup 241}Am for neutron energies between thermal and 320 keV. Preliminary results were also obtained for {sup 243}Am for neutron energies between 35 eV and 200 keV. The results on concurrent neutron-induced fission and neutron-capture measurements on {sup 242m}Am will be presented, where the fission events were actively triggered during the experiments. In these experiments, the Parallel-Plate Avalanche Counter (PPAC) detector that surrounds the target located in themore » center of the DANCE array was used as a fission-tagging detector to separate (n,{gamma}) from (n,f) events. The first evidence of neutron capture on {sup 242m}Am in the resonance region in between 2 and 9 eV of the neutron energy was obtained.« less

  6. Apparatus and method for detecting full-capture radiation events

    DOEpatents

    Odell, D.M.C.

    1994-10-11

    An apparatus and method are disclosed for sampling the output signal of a radiation detector and distinguishing full-capture radiation events from Compton scattering events. The output signal of a radiation detector is continuously sampled. The samples are converted to digital values and input to a discriminator where samples that are representative of events are identified. The discriminator transfers only event samples, that is, samples representing full-capture events and Compton events, to a signal processor where the samples are saved in a three-dimensional count matrix with time (from the time of onset of the pulse) on the first axis, sample pulse current amplitude on the second axis, and number of samples on the third axis. The stored data are analyzed to separate the Compton events from full-capture events, and the energy of the full-capture events is determined without having determined the energies of any of the individual radiation detector events. 4 figs.

  7. Apparatus and method for detecting full-capture radiation events

    DOEpatents

    Odell, Daniel M. C.

    1994-01-01

    An apparatus and method for sampling the output signal of a radiation detector and distinguishing full-capture radiation events from Compton scattering events. The output signal of a radiation detector is continuously sampled. The samples are converted to digital values and input to a discriminator where samples that are representative of events are identified. The discriminator transfers only event samples, that is, samples representing full-capture events and Compton events, to a signal processor where the samples are saved in a three-dimensional count matrix with time (from the time of onset of the pulse) on the first axis, sample pulse current amplitude on the second axis, and number of samples on the third axis. The stored data are analyzed to separate the Compton events from full-capture events, and the energy of the full-capture events is determined without having determined the energies of any of the individual radiation detector events.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Samedov, V. V., E-mail: v-samedov@yandex.ru

    Fluctuations of charge induced by charge carriers on the detector electrodes make a significant contribution to the energy resolution of ionization detectors, namely, semiconductor detectors and gas and liquid ionization chambers. These fluctuations are determined by the capture of charge carriers, as they drift in the bulk of the detector under the action of an electric field, by traps. In this study, we give a correct mathematical description of charge induction on electrodes of an ionization detector for an arbitrary electric field distribution in the detector with consideration of charge carrier capture by traps. The characteristic function obtained in thismore » study yields the general expression for the distribution function of the charge induced on the detector electrodes. The formulas obtained in this study are useful for analysis of the influence of charge carrier transport on energy resolution of ionization detectors.« less

  9. Vertical diffusivity in the benthic boundary layer of the Oregon shelf from a deliberate tracer release experiment

    NASA Astrophysics Data System (ADS)

    Ferrón, S.; Ho, D. T.; Hales, B. R.

    2010-12-01

    A Fluorescein/SF6 deliberate tracer release experiment was conducted in benthic boundary layer (BBL) waters of the outer shelf of Oregon, as part of a multi-disciplinary research project that aims to study cross-shelf carbon transport and biogeochemical reaction rates within the BBL. The purpose of the tracers release was to examine physical transport processes, the rate of turbulent mixing and to provide a Lagrangian frame of reference for tracking other chemical species (pCO2, O2, CH4, DIC, DOC, POC, NO3-, NH4+, Fe). The tracers were injected on May 2009 during moderate upwelling favorable conditions with weak near-bottom currents, along a 4-km N-S line near the shelf streak at the 150 m isobath. Tracers distribution in the patch were tracked for over 5 days by tow-yo surveys using a winch-controlled pumping profiling vehicle that incorporated several in situ instruments such as CTD sensors, a 1200 kHz ADCP and a dye fluorometer for Fluorescein. Dissolved SF6 concentrations were analyzed on board from the underway water stream pumped from the towed vehicle by using an automated high-resolution chromatographic system equipped with an electron capture detector (ECD). The work presented here focuses on the estimation of the effective vertical diffusivity (Kz) in the BBL of the Oregon Shelf from the change in moment of the tracers’ vertical distribution, calculated using a 1D advection-diffusion model.

  10. [Distribution characteristics of organochlorine pesticides in soil from Daiyun Mountain Range in Fujian, China].

    PubMed

    Qu, Cheng-Kai; Qi, Shi-Hua; Zhang, Li; Huang, Huan-Fang; Zhang, Jia-Quan; Zhang, Yuan; Yang, Dan; Liu, Hong-Xia; Chen, Wei

    2013-11-01

    Totally 101 typical surface soil samples were collected from Daiyun Mountain Range, and 20 compounds of OCPs were analyzed by a Ni electron capture detector (GC-ECD) to investigate the horizontal distribution and composition of organochlorine pesticides (OCPs) in the surface soil of Daiyun Mountain Range. The results showed that all OCPs were detected in the soil samples. The detection ratios of OCPs were all over 90%, except for Endrin and beta-HCH. The sum concentration of HCHs, DDTs, Endosulfan and Endosulfan sulfate, accounted for 79.51% of the total OCPs, which were considered to be the dominant OCPs in the Daiyun Mountain Range. The OCPs concentrations in the surface soils ranged from 2.56 to 465.99 ng x g(-1) with a mean value of 38.00 ng x g)(-1). Compared with other regions, the concentrations of HCHs and DDTs in this study stayed in a low pollution level. Endosulfan and Endosulfan sulfate showed a certain degree of risk in the surface soil of the study area. Source analysis showed that new input of lindane and dicofol might occur in the survey region. The historical application was the prime source of Endosulfan. The residue level of OCPs in different lands was in the following order: paddy land > vegetable land > orchard. The OCPs pollution of orchard soil was primarily due to the new input of lindane and dicofol, while the pollution of paddy land was mainly from the usage of Endosulfan.

  11. [Analysis of pesticides including chlorine in welsh onions and mushrooms using gas chromatograph with an atomic emission detector (GC-AED)].

    PubMed

    Tateishi, Yukinari; Takano, Ichiro; Kobayashi, Maki; Tamura, Yasuhiro; Tomizawa, Sanae; Sakai, Naoko; Kamijo, Kyoko; Nagayama, Toshihiro; Kamata, Kunihiro

    2004-12-01

    An analytical method for the determination of 32 kinds of pesticide residues in onions, Welsh onions and mushrooms using gas chromatograph with an atomic emission detector (GC-AED) was developed. The pesticides were extracted with acetone-n-hexane (2:3) mixture. The crude extract was partitioned between 5% sodium chloride and ethyl acetate-n-hexane (1:4) mixture. The extract was passed through a Florisil mini-column for cleanup with 10 mL of acetone-n-hexane (1:9) mixture. Although the sensitivity of GC-AED was inferior to that of GC-ECD, GC-AED has a superior element-selectivity. Therefore pesticide residues in foods could be analyzed more exactly by using GC-AED. Thirty-two pesticides including chlorine in onion, Welsh onion and shiitake mushroom were detected without interference. Recoveries of these pesticides from samples determined by GC-AED were 64-114%, except for a few pesticides.

  12. Determination of trace level genotoxic impurities in small molecule drug substances using conventional headspace gas chromatography with contemporary ionic liquid diluents and electron capture detection.

    PubMed

    Ho, Tien D; Yehl, Peter M; Chetwyn, Nik P; Wang, Jin; Anderson, Jared L; Zhong, Qiqing

    2014-09-26

    Ionic liquids (ILs) were used as a new class of diluents for the analysis of two classes of genotoxic impurities (GTIs), namely, alkyl/aryl halides and nitro-aromatics, in small molecule drug substances by headspace gas chromatography (HS-GC) coupled with electron capture detection (ECD). This novel approach using ILs as contemporary diluents greatly broadens the applicability of HS-GC for the determination of high boiling (≥ 130°C) analytes including GTIs with limits of detection (LOD) ranging from 5 to 500 parts-per-billion (ppb) of analytes in a drug substance. This represents up to tens of thousands-fold improvement compared to traditional HS-GC diluents such as dimethyl sulfoxide (DMSO) and dimethylacetamide (DMAC). Various ILs were screened to determine their suitability as diluents for the HS-GC/ECD analysis. Increasing the HS oven temperatures resulted in varying responses for alkyl/aryl halides and a significant increase in response for all nitroaromatic GTIs. Linear ranges of up to five orders of magnitude were found for a number of analytes. The technique was validated on two active pharmaceutical ingredients with excellent recovery. This simple and robust methodology offers a key advantage in the ease of method transfer from development laboratories to quality control environments since conventional validated chromatographic data systems and GC instruments can be used. For many analytes, it is a cost effective alternative to more complex trace analytical methodologies like LC/MS and GC/MS, and significantly reduces the training needed for operation. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Separation and screening of short-chain chlorinated paraffins in environmental samples using comprehensive two-dimensional gas chromatography with micro electron capture detection.

    PubMed

    Xia, Dan; Gao, Lirong; Zhu, Shuai; Zheng, Minghui

    2014-11-01

    Short-chain chlorinated paraffins (SCCPs) are highly complex technical mixtures with thousands of isomers and numerous homologs. They are classified as priority candidate persistent organic pollutants under the Stockholm Convention for their persistence, bioaccumulation, and toxicity. Analyzing SCCPs is challenging because of the complexity of the mixtures. Chromatograms of SCCPs acquired using one-dimensional (1D) gas chromatography (GC) contain a large characteristic "peak" with a broad and unresolved profile. Comprehensive two-dimensional GC (GC×GC) shows excellent potential for separating complex mixtures. In this study, GC×GC coupled with micro electron capture detection (μECD) was used to separate and screen SCCPs. The chromatographic parameters, including the GC column types, oven temperature program, and modulation period, were systematically optimized. The SCCP congeners were separated into groups using a DM-1 column connected to a BPX-50 column. The SCCP congeners in technical mixtures were separated according to the number of chlorine substituents for a given carbon chain length and according to the number of carbon atoms plus chlorine atoms for different carbon chain lengths. A fish tissue sample was analyzed to illustrate the feasibility of the GC×GC-μECD method in analyzing biological samples. Over 1,500 compounds were identified in the fish extract, significantly more than were identified using 1D GC. The detection limits for five selected SCCP congeners were between 1 and 5 pg/L using the GC×GC method, and these were significantly lower than those achieved using 1D GC. This method is a good choice for analysis of SCCPs in environmental samples, exhibiting good separation and good sensitivity.

  14. Determining the Binding Sites of β-Cyclodextrin and Peptides by Electron-Capture Dissociation High Resolution Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Qi, Yulin; Geib, Timon; Volmer, Dietrich A.

    2015-07-01

    Cyclodextrins (CDs) are a group of cyclic oligosaccharides, which readily form inclusion complexes with hydrophobic compounds to increase bioavailability, thus making CDs ideal drug excipients. Recent studies have also shown that CDs exhibit a wide range of protective effects, preventing proteins from aggregation, degradation, and folding. These effects strongly depend on the binding sites on the protein surface. CDs only exhibit weak interactions with amino acids, however; conventional analytical techniques therefore usually fail to reveal the exact location of the binding sites. Moreover, some studies even suggest that CD inclusion complexes are merely electrostatic adducts. Here, electron capture dissociation (ECD) was applied in this proof-of-concept study to examine the exact nature of the CD/peptide complexes, and CD binding sites were unambiguously located for the first time via Fourier-transform ion cyclotron resonance (FTICR) tandem mass spectrometry.

  15. Epidemiology of Kidney Discard from Expanded Criteria Donors Undergoing Donation after Circulatory Death.

    PubMed

    Singh, Sunita K; Kim, S Joseph

    2016-02-05

    The broader use of combined expanded criteria donor and donation after circulatory death (ECD/DCD) kidneys may help expand the deceased donor pool. The purpose of our study was to evaluate discard rates of kidneys from ECD/DCD donors and factors associated with discard. ECD/DCD donors and kidneys were evaluated from January 1, 2000 to March 31, 2011 using data from the Scientific Registry of Transplant Recipients. The kidney donor risk index was calculated for all ECD/DCD kidneys. Multivariable logistic regression models were used to determine risk factors for discarding both donor kidneys. The Kaplan-Meier product limit method and the log-rank statistic were used to assess the cumulative probability of graft failure for transplants from ECD/DCD donors where the mate kidney was discarded versus both kidneys were used. There were 896 ECD/DCD donors comprising 1792 kidneys. Both kidneys were discarded in 44.5% of donors, whereas 51.0% of all available kidneys were discarded. The kidney donor risk index scores were higher among donors of discarded versus transplanted kidneys (median, 1.82; interquartile range, 1.60, 2.07 versus median, 1.67; interquartile range, 1.49, 1.87, respectively; P<0.001); however, the distributions showed considerable overlap. The adjusted odds ratios for discard were higher among donors who were older, diabetic, AB blood type, and hepatitis C positive. The cumulative probabilities of total graft failure at 1, 3, and 5 years were 17.3%, 36.5%, and 55.4% versus 13.8%, 24.7%, and 40.5% among kidneys from donors where only one versus both kidneys were transplanted, respectively (log rank P=0.04). Our study shows a significantly higher discard rate for ECD/DCD kidneys versus prior reports. Some discarded ECD/DCD kidneys may be acceptable for transplantation. Additional studies are needed to evaluate the factors that influence decision making around the use of ECD/DCD kidneys. Copyright © 2016 by the American Society of Nephrology.

  16. Modeling the Sustainability of a Ceramic Water Filter Intervention

    PubMed Central

    Mellor, Jonathan; Abebe, Lydia; Ehdaie, Beeta; Dillingham, Rebecca; Smith, James

    2014-01-01

    Ceramic water filters (CWFs) are a point-of-use water treatment technology that has shown promise in preventing early childhood diarrhea (ECD) in resource-limited settings. Despite this promise, some researchers have questioned their ability to reduce ECD incidences over the long term since most effectiveness trials conducted to date are less than one year in duration limiting their ability to assess long-term sustainability factors. Most trials also suffer from lack of blinding making them potentially biased. This study uses an agent-based model (ABM) to explore factors related to the long-term sustainability of CWFs in preventing ECD and was based on a three year longitudinal field study. Factors such as filter user compliance, microbial removal effectiveness, filter cleaning and compliance declines were explored. Modeled results indicate that broadly defined human behaviors like compliance and declining microbial effectiveness due to improper maintenance are primary drivers of the outcome metrics of household drinking water quality and ECD rates. The model predicts that a ceramic filter intervention can reduce ECD incidence amongst under two year old children by 41.3%. However, after three years, the average filter is almost entirely ineffective at reducing ECD incidence due to declining filter microbial removal effectiveness resulting from improper maintenance. The model predicts very low ECD rates are possible if compliance rates are 80-90%, filter log reduction efficiency is 3 or greater and there are minimal long-term compliance declines. Cleaning filters at least once every 4 months makes it more likely to achieve very low ECD rates as does the availability of replacement filters for purchase. These results help to understand the heterogeneity seen in previous intervention-control trials and reemphasize the need for researchers to accurately measure confounding variables and ensure that field trials are at least 2-3 years in duration. In summary, the CWF can be a highly effective tool in the fight against ECD, but every effort should be made by implementing agencies to ensure consistent use and maintenance. PMID:24355289

  17. Preoperative serum HER2 extracellular domain levels in primary invasive breast cancer.

    PubMed

    Lee, Sae Byul; Lee, Jong Won; Yu, Jong Han; Ko, Beom Seok; Kim, Hee Jeong; Son, Byung Ho; Gong, Gyungyub; Lee, Hee Jin; Kim, Sung-Bae; Jung, Kyung Hae; Ahn, Jin-Hee; Lee, Woochang; Sung, Joohon; Ahn, Sei-Hyun

    2014-12-10

    Despite the preclinical outcomes and biologic significance of the presence of the human epidermal growth factor receptor-2 (HER2) extracellular domain (ECD), there is little evidence supporting the measurement of ECD levels in any clinical setting. The aim of this study was to determine the prevalence of elevated serum HER2 ECD levels, the association between these levels and tissue HER2 overexpression, and the potential clinical prognostic value of HER2 ECD in primary invasive breast cancer. Serum HER2 ECD levels were examined preoperatively in 2,862 consecutive stage I-III primary breast cancer patients between 2007 and 2009. Serum HER2 ECD levels were measured by chemiluminescence immunoassay (ADVIA Centaur), and the tissue HER2 status was assessed by immunohistochemistry and fluorescence in situ hybridization. The cutoff value for the serum level of HER2 ECD was set at 15.2 ng/ml. Among the 2,862 patients, 126 (4.4%) had elevated serum HER2 ECD levels, and HER2 was overexpressed in the tumor tissue of 692 patients (24.2%), with a concordance of 78.7%. Multivariate analysis revealed that elevated serum HER2 ECD was a significant independent prognostic factor for worse distant-metastasis-free survival [DMFS; hazard ratio (HR) = 2.50, 95% confidence interval (CI) = 1.5-4.3, P = 0.001] and breast-cancer-specific survival (BCSS; HR = 2.0, 95% CI = 1.1-3.8, P = 0.036), which were much stronger in patients with tissue HER2-positive tumors (DMFS: HR = 3.8, 95% CI = 2.0-7.0, P < 0.001; BCSS: HR = 2.6, 95% CI = 1.2-5.3, P = 0.012). Given the prevalence of HER2 expression, its measurement as an independent prognostic factor can be clinically useful, particularly in patients with tissue HER2-positive tumors.

  18. Epidemiology of Kidney Discard from Expanded Criteria Donors Undergoing Donation after Circulatory Death

    PubMed Central

    Singh, Sunita K.

    2016-01-01

    Background and objectives The broader use of combined expanded criteria donor and donation after circulatory death (ECD/DCD) kidneys may help expand the deceased donor pool. The purpose of our study was to evaluate discard rates of kidneys from ECD/DCD donors and factors associated with discard. Design, setting, participants, & measurements ECD/DCD donors and kidneys were evaluated from January 1, 2000 to March 31, 2011 using data from the Scientific Registry of Transplant Recipients. The kidney donor risk index was calculated for all ECD/DCD kidneys. Multivariable logistic regression models were used to determine risk factors for discarding both donor kidneys. The Kaplan–Meier product limit method and the log-rank statistic were used to assess the cumulative probability of graft failure for transplants from ECD/DCD donors where the mate kidney was discarded versus both kidneys were used. Results There were 896 ECD/DCD donors comprising 1792 kidneys. Both kidneys were discarded in 44.5% of donors, whereas 51.0% of all available kidneys were discarded. The kidney donor risk index scores were higher among donors of discarded versus transplanted kidneys (median, 1.82; interquartile range, 1.60, 2.07 versus median, 1.67; interquartile range, 1.49, 1.87, respectively; P<0.001); however, the distributions showed considerable overlap. The adjusted odds ratios for discard were higher among donors who were older, diabetic, AB blood type, and hepatitis C positive. The cumulative probabilities of total graft failure at 1, 3, and 5 years were 17.3%, 36.5%, and 55.4% versus 13.8%, 24.7%, and 40.5% among kidneys from donors where only one versus both kidneys were transplanted, respectively (log rank P=0.04). Conclusions Our study shows a significantly higher discard rate for ECD/DCD kidneys versus prior reports. Some discarded ECD/DCD kidneys may be acceptable for transplantation. Additional studies are needed to evaluate the factors that influence decision making around the use of ECD/DCD kidneys. PMID:26668028

  19. Neutron capture measurement on {sup 173}Lu at LANSCE with DANCE detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Theroine, C.; Ebran, A.; Meot, V.

    2013-06-10

    The (n,{gamma}) cross section on the unstable {sup 173}Lu(t{sub 1/2} = 1.37y) has been measured from thermal energy up to 200 eV at Los Alamos Neutron Science Center (LANSCE) with The Detector for Advanced Neutron Capture Experiements (DANCE). The main aim of this study is to validate and optimize reaction models for unstable nucleus. A preliminary capture yield will be presented in this paper.

  20. Differential Requirement of the Extracellular Domain in Activation of Class B G Protein-coupled Receptors.

    PubMed

    Zhao, Li-Hua; Yin, Yanting; Yang, Dehua; Liu, Bo; Hou, Li; Wang, Xiaoxi; Pal, Kuntal; Jiang, Yi; Feng, Yang; Cai, Xiaoqing; Dai, Antao; Liu, Mingyao; Wang, Ming-Wei; Melcher, Karsten; Xu, H Eric

    2016-07-15

    G protein-coupled receptors (GPCRs) from the secretin-like (class B) family are key players in hormonal homeostasis and are important drug targets for the treatment of metabolic disorders and neuronal diseases. They consist of a large N-terminal extracellular domain (ECD) and a transmembrane domain (TMD) with the GPCR signature of seven transmembrane helices. Class B GPCRs are activated by peptide hormones with their C termini bound to the receptor ECD and their N termini bound to the TMD. It is thought that the ECD functions as an affinity trap to bind and localize the hormone to the receptor. This in turn would allow the hormone N terminus to insert into the TMD and induce conformational changes of the TMD to activate downstream signaling. In contrast to this prevailing model, we demonstrate that human class B GPCRs vary widely in their requirement of the ECD for activation. In one group, represented by corticotrophin-releasing factor receptor 1 (CRF1R), parathyroid hormone receptor (PTH1R), and pituitary adenylate cyclase activating polypeptide type 1 receptor (PAC1R), the ECD requirement for high affinity hormone binding can be bypassed by induced proximity and mass action effects, whereas in the other group, represented by glucagon receptor (GCGR) and glucagon-like peptide-1 receptor (GLP-1R), the ECD is required for signaling even when the hormone is covalently linked to the TMD. Furthermore, the activation of GLP-1R by small molecules that interact with the intracellular side of the receptor is dependent on the presence of its ECD, suggesting a direct role of the ECD in GLP-1R activation. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.

  1. The clinical spectrum of Erdheim-Chester disease: an observational cohort study

    PubMed Central

    O’Brien, Kevin J.; Xi, Liqiang; Malayeri, Ashkan A.; Gardner, Pamela J.; Alvarado Enriquez, Jhonell R.; Shah, Nikeith; Gochuico, Bernadette R.; Raffeld, Mark; Gahl, William A.

    2017-01-01

    Erdheim-Chester disease (ECD) is a rare, potentially fatal multiorgan myeloid neoplasm occurring mainly in adults. The diagnosis is established by clinical, radiologic, and histologic findings; ECD tumors contain foamy macrophages that are CD68+, CD163+, CD1a−, and frequently S100−. The purpose of this report is to describe the clinical and molecular variability of ECD. Between 2011 and 2015, 60 consecutive ECD patients (45 males, 15 females) were prospectively evaluated at the National Institutes of Health Clinical Center. Comprehensive imaging and laboratory studies were performed, and tissues were examined for BRAF V600E and MAPK pathway mutations. Mean age at first manifestations of ECD was 46 years; a diagnosis was established, on average, 4.2 years after initial presentation. Bone was the most common tissue affected, with osteosclerosis in 95% of patients. Other manifestations observed in one-third to two-thirds of patients included cardiac mass and periaortic involvement, diabetes insipidus, retro-orbital infiltration, retroperitoneal, lung, central nervous system, skin, and xanthelasma, affecting patients in variable ways. Methods of detection included imaging studies of various modalities. Mutation in BRAF V600E was detected in 51% of 57 biopsy specimens. One patient had an ARAF D228V mutation, and 1 patient had an activating ALK fusion. Treatments included interferon α, imatinib, anakinra, cladribine, vemurafenib, and dabrafenib with trametinib; 11 patients received no therapy. The diagnosis of ECD is elusive because of the rarity and varied presentations of the disorder. Identification of BRAF and other MAPK pathway mutations in biopsy specimens improves ECD diagnosis, allows for development of targeted treatments, and demonstrates that ECD is a neoplastic disorder. This study was registered at www.clinicaltrials.gov as #NCT01417520. PMID:28553668

  2. Reversibly bound chloride in the atrial natriuretic peptide receptor hormone-binding domain: possible allosteric regulation and a conserved structural motif for the chloride-binding site.

    PubMed

    Ogawa, Haruo; Qiu, Yue; Philo, John S; Arakawa, Tsutomu; Ogata, Craig M; Misono, Kunio S

    2010-03-01

    The binding of atrial natriuretic peptide (ANP) to its receptor requires chloride, and it is chloride concentration dependent. The extracellular domain (ECD) of the ANP receptor (ANPR) contains a chloride near the ANP-binding site, suggesting a possible regulatory role. The bound chloride, however, is completely buried in the polypeptide fold, and its functional role has remained unclear. Here, we have confirmed that chloride is necessary for ANP binding to the recombinant ECD or the full-length ANPR expressed in CHO cells. ECD without chloride (ECD(-)) did not bind ANP. Its binding activity was fully restored by bromide or chloride addition. A new X-ray structure of the bromide-bound ECD is essentially identical to that of the chloride-bound ECD. Furthermore, bromide atoms are localized at the same positions as chloride atoms both in the apo and in the ANP-bound structures, indicating exchangeable and reversible halide binding. Far-UV CD and thermal unfolding data show that ECD(-) largely retains the native structure. Sedimentation equilibrium in the absence of chloride shows that ECD(-) forms a strongly associated dimer, possibly preventing the structural rearrangement of the two monomers that is necessary for ANP binding. The primary and tertiary structures of the chloride-binding site in ANPR are highly conserved among receptor-guanylate cyclases and metabotropic glutamate receptors. The chloride-dependent ANP binding, reversible chloride binding, and the highly conserved chloride-binding site motif suggest a regulatory role for the receptor bound chloride. Chloride-dependent regulation of ANPR may operate in the kidney, modulating ANP-induced natriuresis.

  3. Reversibly Bound Chloride in the Atrial Natriuretic Peptide Receptor Hormone Binding Domain: Possible Allosteric Regulation and a Conserved Structural Motif for the Chloride-binding Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ogawa, H.; Qiu, Y; Philo, J

    2010-01-01

    The binding of atrial natriuretic peptide (ANP) to its receptor requires chloride, and it is chloride concentration dependent. The extracellular domain (ECD) of the ANP receptor (ANPR) contains a chloride near the ANP-binding site, suggesting a possible regulatory role. The bound chloride, however, is completely buried in the polypeptide fold, and its functional role has remained unclear. Here, we have confirmed that chloride is necessary for ANP binding to the recombinant ECD or the full-length ANPR expressed in CHO cells. ECD without chloride (ECD(-)) did not bind ANP. Its binding activity was fully restored by bromide or chloride addition. Amore » new X-ray structure of the bromide-bound ECD is essentially identical to that of the chloride-bound ECD. Furthermore, bromide atoms are localized at the same positions as chloride atoms both in the apo and in the ANP-bound structures, indicating exchangeable and reversible halide binding. Far-UV CD and thermal unfolding data show that ECD(-) largely retains the native structure. Sedimentation equilibrium in the absence of chloride shows that ECD(-) forms a strongly associated dimer, possibly preventing the structural rearrangement of the two monomers that is necessary for ANP binding. The primary and tertiary structures of the chloride-binding site in ANPR are highly conserved among receptor-guanylate cyclases and metabotropic glutamate receptors. The chloride-dependent ANP binding, reversible chloride binding, and the highly conserved chloride-binding site motif suggest a regulatory role for the receptor bound chloride. Chloride-dependent regulation of ANPR may operate in the kidney, modulating ANP-induced natriuresis.« less

  4. Reversibly bound chloride in the atrial natriuretic peptide receptor hormone-binding domain: Possible allosteric regulation and a conserved structural motif for the chloride-binding site

    PubMed Central

    Ogawa, Haruo; Qiu, Yue; Philo, John S; Arakawa, Tsutomu; Ogata, Craig M; Misono, Kunio S

    2010-01-01

    The binding of atrial natriuretic peptide (ANP) to its receptor requires chloride, and it is chloride concentration dependent. The extracellular domain (ECD) of the ANP receptor (ANPR) contains a chloride near the ANP-binding site, suggesting a possible regulatory role. The bound chloride, however, is completely buried in the polypeptide fold, and its functional role has remained unclear. Here, we have confirmed that chloride is necessary for ANP binding to the recombinant ECD or the full-length ANPR expressed in CHO cells. ECD without chloride (ECD(−)) did not bind ANP. Its binding activity was fully restored by bromide or chloride addition. A new X-ray structure of the bromide-bound ECD is essentially identical to that of the chloride-bound ECD. Furthermore, bromide atoms are localized at the same positions as chloride atoms both in the apo and in the ANP-bound structures, indicating exchangeable and reversible halide binding. Far-UV CD and thermal unfolding data show that ECD(−) largely retains the native structure. Sedimentation equilibrium in the absence of chloride shows that ECD(−) forms a strongly associated dimer, possibly preventing the structural rearrangement of the two monomers that is necessary for ANP binding. The primary and tertiary structures of the chloride-binding site in ANPR are highly conserved among receptor-guanylate cyclases and metabotropic glutamate receptors. The chloride-dependent ANP binding, reversible chloride binding, and the highly conserved chloride-binding site motif suggest a regulatory role for the receptor bound chloride. Chloride-dependent regulation of ANPR may operate in the kidney, modulating ANP-induced natriuresis. PMID:20066666

  5. The effect of an Ahmed glaucoma valve implant on corneal endothelial cell density in children with glaucoma secondary to uveitis.

    PubMed

    Kalinina Ayuso, Viera; Scheerlinck, Laura M; de Boer, Joke H

    2013-03-01

    To assess the effect of Ahmed glaucoma valve implants on corneal endothelial cell density (ECD) in children with uveitic glaucoma. Cross-sectional study. setting: Institutional. patientpopulation: Eighty eyes from 42 patients diagnosed with uveitis before the age of 16. Twenty-eight eyes had an Ahmed glaucoma valve implant because of secondary glaucoma. Fifty-two eyes without an implant served as controls. intervention orobservationprocedure(s): Corneal ECD was examined cross-sectionally using a noncontact specular microscope. Univariate and multivariate generalized estimating equations analyses with correction for paired eyes were performed. mainoutcomemeasure(s): Correlation of ECD with the presence of an Ahmed glaucoma valve implant and with the time following implantation. ECD was significantly lower in the Ahmed glaucoma valve group than in controls (2359 and 3088 cells/mm(2), respectively; P < .001) following an average of 3.5 years after Ahmed glaucoma valve implantation. Presence of an Ahmed glaucoma valve implant, previous intraocular surgery, age, duration of uveitis, and history of corneal touch by the implant tube were all significantly associated with decreased ECD. Following a multivariate analysis, presence of an Ahmed glaucoma valve implant (B = -340; adjusted P < .011) and older age (B = -58; adjusted P = .005) remained independently associated with decreased ECD. Within the implant group, the age-adjusted time interval following Ahmed glaucoma valve implantation was highly correlated with decreased ECD (B = -558, P < .001). Ahmed glaucoma valve implants in children with uveitic glaucoma are independently associated with decreased ECD, and this effect is associated with the time interval following Ahmed glaucoma valve implantation. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Analyses of Factors Affecting Endothelial Cell Density in an Eye Bank Corneal Donor Database.

    PubMed

    Kwon, Ji Won; Cho, Kyong Jin; Kim, Hong Kyu; Lee, Jimmy K; Gore, Patrick K; McCartney, Mitchell D; Chuck, Roy S

    2016-09-01

    To analyze the factors affecting central corneal endothelial cell density (ECD) in an eye bank corneal donor database. The Lion's Eye Institute corneal donor database consisting of 18,665 donors (34,234 corneas) aged 20 years or older was analyzed. In particular, differences in the ECD based on age, sex, race, prior ocular surgery, a history of systemic diseases, and smoking were investigated. Furthermore, risk factors for donor cell count inadequacy (defined here as ECD less than 2000/mm) were identified. ECD decreased with age. Regarding race, the average ECD of African American donors was higher than those of white or Hispanic donors. A history of diabetes mellitus (DM) and ocular surgery were associated with a lower ECD. Donor medical history of hypertension, glaucoma, depression, dementia, Parkinson disease, hyper- or hypothyroidism, or smoking did not seem to affect the ECD. The risk factors for donor cell count inadequacy, based on binary logistic regression analyses were advanced age [65-74 years yielded an odds ratio of 17.8; confidence interval (CI), 10.6-29.8; P < 0.001; and 75-99 years yielded an odds ratio of 24.6 (CI, 14.5-41.61; P < 0.001) when compared with 20-34 years], cataract surgery (odds ratio, 4.3; CI, 4.0-4.8; P < 0.001), and DM (odds ratio, 1.2; CI, 1.1-1.3; P = 0.001). Age, race, ocular surgery (cataract and refractive), and DM seem to significantly affect donor corneal ECD. Of these variables, age, a history of cataract surgery, and DM were found to be the greatest risk factors for inadequate donor cell density (less than 2000/mm).

  7. Research priority setting for integrated early child development and violence prevention (ECD+) in low and middle income countries: An expert opinion exercise.

    PubMed

    Tomlinson, Mark; Jordans, Mark; MacMillan, Harriet; Betancourt, Theresa; Hunt, Xanthe; Mikton, Christopher

    2017-10-01

    Child development in low and middle income countries (LMIC) is compromised by multiple risk factors. Reducing children's exposure to harmful events is essential for early childhood development (ECD). In particular, preventing violence against children - a highly prevalent risk factor that negatively affects optimal child development - should be an intervention priority. We used the Child Health and Nutrition Initiative (CHNRI) method for the setting of research priorities in integrated Early Childhood Development and violence prevention programs (ECD+). An expert group was identified and invited to systematically list and score research questions. A total of 186 stakeholders were asked to contribute five research questions each, and contributions were received from 81 respondents. These were subsequently evaluated using a set of five criteria: answerability; effectiveness; feasibility and/or affordability; applicability and impact; and equity. Of the 400 questions generated, a composite group of 50 were scored by 55 respondents. The highest scoring research questions related to the training of Community Health Workers (CHW's) to deliver ECD+ interventions effectively and whether ECD+ interventions could be integrated within existing delivery platforms such as HIV, nutrition or mental health platforms. The priority research questions can direct new research initiatives, mainly in focusing on the effectiveness of an ECD+ approach, as well as on service delivery questions. To the best of our knowledge, this is the first systematic exercise of its kind in the field of ECD+. The findings from this research priority setting exercise can help guide donors and other development actors towards funding priorities for important future research related to ECD and violence prevention. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. The levels of bone alkaline phosphatase (BALP) and soluble epidermal growth factor receptor-2 (ECD/HER-2) in pediatric patients with osteosarcoma during clinical treatment.

    PubMed

    Rychłowska-Pruszyńska, Magdalena; Gajewska, Joanna; Ambroszkiewicz, Jadwiga; Karwacki, Marek; Szamotulska, Katarzyna

    2018-01-01

    Aim: The aim of this study was to assess the usefulness of bone-specific alkaline phosphatase (BALP) and the extracelluar domain of human epidermal growth factor receptor 2 (ECD/HER-2) measurements in pediatric patients with osteosarcoma as prospective prognostic and predictive markers for monitoring the treatment and early detection of disease recurrence. Material and methods: We studied 22 patients (5 girls, 17 boys) aged 7-20 years with osteosarcoma (OS) treated at the Institute of Mother and Child in Warsaw. All the patients were evaluated for the serum levels of BALP and ECD/HER-2 before treatment, during pre- and postoperative chemotherapy and after the completion of treatment. Healthy children (n=22) were the reference group. The levels of BALP and ECD/HER-2 were measured using immunoenzymatic methods. Results: The values of BALP and ECD/HER-2 proteins were higher (p<0.01; p<0.05, respectively) in patients with osteosarcoma at the time of diagnosis compared with the control group. The values of both markers significantly decreased during chemotherapy in most patients with remission. In contrast to ECD/HER-2, the value of BALP after therapy was higher in patients with progression than with remission (p<0.001). Conclusions: Our results demonstrate the different pattern of BALP and ECD/HER-2 proteins during clinical treatment in patients with osteosarcoma. Higher values of BALP may characterize the progression of the disease and unfavourable prognosis. Further longitudinal studies are necessary to confirm the prognostic values of BALP and ECD/HER-2 proteins in this group of patients.

  9. Analysis of MCNP simulated gamma spectra of CdTe detectors for boron neutron capture therapy.

    PubMed

    Winkler, Alexander; Koivunoro, Hanna; Savolainen, Sauli

    2017-06-01

    The next step in the boron neutron capture therapy (BNCT) is the real time imaging of the boron concentration in healthy and tumor tissue. Monte Carlo simulations are employed to predict the detector response required to realize single-photon emission computed tomography in BNCT, but have failed to correctly resemble measured data for cadmium telluride detectors. In this study we have tested the gamma production cross-section data tables of commonly used libraries in the Monte Carlo code MCNP in comparison to measurements. The cross section data table TENDL-2008-ACE is reproducing measured data best, whilst the commonly used ENDL92 and other studied libraries do not include correct tables for the gamma production from the cadmium neutron capture reaction that is occurring inside the detector. Furthermore, we have discussed the size of the annihilation peaks of spectra obtained by cadmium telluride and germanium detectors. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Using the ECD Framework to Support Evidentiary Reasoning in the Context of a Simulation Study for Detecting Learner Differences in Epistemic Games

    ERIC Educational Resources Information Center

    Sweet, Shauna J.; Rupp, Andre A.

    2012-01-01

    The "evidence-centered design" (ECD) framework is a powerful tool that supports careful and critical thinking about the identification and accumulation of evidence in assessment contexts. In this paper, we demonstrate how the ECD framework provides critical support for designing simulation studies to investigate statistical methods…

  11. Hand-Schüller-Christian Disease and Erdheim-Chester Disease: Coexistence and Discrepancy

    PubMed Central

    Yin, Jun; Zhang, Feng; Zhang, Huizhen; Shen, Li; Li, Qing; Hu, Shundong; Tian, Qinghua; Bao, Yuqian

    2013-01-01

    Langerhans cell histiocytosis (LCH) and Erdheim-Chester disease (ECD) share similar clinical features and mechanisms. In very rare circumstances, the two diseases coexist in the same patient. Here we report such a patient, who was first diagnosed with Hand-Schüller-Christian disease (HSC), a type of LCH. Several years later, the patient presented with severe exophthalmos and osteosclerosis on radiograph. New biopsy revealed ECD. We also analyze 54 cases of LCH and 6 cases of ECD diagnosed in our hospital, as well as their progression during a follow-up period of 8 years. In five cases of HSC (9.3% of LCH), a triad of central diabetes insipidus, hyperprolactinemia, and pituitary stalk thickening on magnetic resonance imaging (MRI) preceded the typical bone lesions by 4–9 years. In addition, LCH was featured as elevated plasma alkaline phosphatase (ALP), which was normal in ECD. Combined with a literature review, several features are summarized to differentiate ECD from HSC. In patients with diabetes insipidus, concomitant hyperprolactinemia and pituitary stalk thickening on MRI indicate a possible HSC. Additionally, if osteosclerosis is observed in a patient with LCH, the coexistence of ECD should be considered. PMID:23299772

  12. Capture and fission with DANCE and NEUANCE

    DOE PAGES

    Jandel, M.; Baramsai, B.; Bond, E.; ...

    2015-12-23

    A summary of the current and future experimental program at DANCE is presented. Measurements of neutron capture cross sections are planned for many actinide isotopes with the goal to reduce the present uncertainties in nuclear data libraries. Detailed studies of capture gamma rays in the neutron resonance region will be performed in order to derive correlated data on the de-excitation of the compound nucleus. New approaches on how to remove the DANCE detector response from experimental data and retain the correlations between the cascade gamma rays are presented. Studies on 235U are focused on quantifying the population of short-lived isomericmore » states in 236U after neutron capture. For this purpose, a new neutron detector array NEUANCE is under construction. It will be installed in the central cavity of the DANCE array and enable the highly efficient tagging of fission and capture events. In addition, developments of fission fragment detectors are also underway to expand DANCE capabilities to measurements of fully correlated data on fission observables.« less

  13. Current and Future Research at DANCE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jandel, M.; Baramsai, B.; Bredeweg, T. A.

    2015-05-28

    An overview of the current experimental program on measurements of neutron capture and neutron induced fission at the Detector for Advanced Neutron Capture Experiments (DANCE) is presented. Three major projects are currently under way: 1) high precision measurements of neutron capture cross sections on Uranium isotopes, 2) research aimed at studies of the short-lived actinide isomer production in neutron capture on 235U and 3) measurements of correlated data of fission observables. New projects include developments of auxiliary detectors to improve the capability of DANCE. We are building a compact, segmented NEUtron detector Array at DANCE (NEUANCE), which will be installedmore » in the central cavity of the DANCE array. It will thus provide experimental information on prompt fission neutrons in coincidence with the prompt fission gamma-rays measured by 160 BaF 2 crystals of DANCE. Additionally, unique correlated data will be obtained for neutron capture and neutron-induced fission using the DANCE-NEUANCE experimental set up in the future.« less

  14. Capture and fission with DANCE and NEUANCE

    NASA Astrophysics Data System (ADS)

    Jandel, M.; Baramsai, B.; Bond, E.; Rusev, G.; Walker, C.; Bredeweg, T. A.; Chadwick, M. B.; Couture, A.; Fowler, M. M.; Hayes, A.; Kawano, T.; Mosby, S.; Stetcu, I.; Taddeucci, T. N.; Talou, P.; Ullmann, J. L.; Vieira, D. J.; Wilhelmy, J. B.

    2015-12-01

    A summary of the current and future experimental program at DANCE is presented. Measurements of neutron capture cross sections are planned for many actinide isotopes with the goal to reduce the present uncertainties in nuclear data libraries. Detailed studies of capture gamma rays in the neutron resonance region will be performed in order to derive correlated data on the de-excitation of the compound nucleus. New approaches on how to remove the DANCE detector response from experimental data and retain the correlations between the cascade gamma rays are presented. Studies on 235U are focused on quantifying the population of short-lived isomeric states in 236U after neutron capture. For this purpose, a new neutron detector array NEUANCE is under construction. It will be installed in the central cavity of the DANCE array and enable the highly efficient tagging of fission and capture events. In addition, developments of fission fragment detectors are also underway to expand DANCE capabilities to measurements of fully correlated data on fission observables.

  15. Evaluating the potential of (188)Re-ECD/lipiodol as a therapeutic radiopharmaceutical by intratumoral injection for hepatoma treatment.

    PubMed

    Luo, Tsai-Yueh; Shih, Ying-Hsia; Chen, Chiung-Yu; Tang, I-Chung; Wu, Yu-Long; Kung, Hong-Chang; Lin, Wuu-Jyh; Lin, Xi-Zhang

    2009-10-01

    Intratumoral injection of a radiopharmaceutical is a potential modality to treat liver tumors. Rhenium-188 ((188)Re) was used to chelate with ethyl cysteinate dimer (ECD) in lipiodol solution to form (188)Re-ECD/lipiodol, which was then evaluated for its therapeutic potential in a rodent hepatoma model. Male Sprague-Dawley rats were implanted with N1-S1 hepatoma cells orthotopically and randomly divided into two groups. Group 1 (n = 29) and group 2 (n = 10) received (188)Re-ECD/lipiodol (30.4 +/- 21.8 MBq/0.1 mL) and 0.1 mL of normal saline by intratumoral injection, respectively. Three rats in group 1 were imaged by micro-single-photon emission computed tomography/computed tomography scan to evaluate the biodistribution pattern. All rats were monitored for change of tumor size and survival rate after 2 months. The in vitro stability test showed that (188)Re-ECD was well-retained in the lipiodol phase for 48 hours. The biodistribution image revealed that radioactivity was retained well in hepatomas 24 hours postinjection. Long-term studies demonstrated that rats treated with (188)Re-ECD/Lipiodol had smaller tumor volumes and a better survival rate, compared to the control group. At the end of observation, the survival rates in groups 1 and 2 were 62% and 20%, respectively (p < 0.05). (188)Re-ECD/lipiodol via direct intratumoral injection shows potential for treating hepatoma and warrants further clinical trials.

  16. Prompt gamma and neutron detection in BNCT utilizing a CdTe detector.

    PubMed

    Winkler, Alexander; Koivunoro, Hanna; Reijonen, Vappu; Auterinen, Iiro; Savolainen, Sauli

    2015-12-01

    In this work, a novel sensor technology based on CdTe detectors was tested for prompt gamma and neutron detection using boronated targets in (epi)thermal neutron beam at FiR1 research reactor in Espoo, Finland. Dedicated neutron filter structures were omitted to enable simultaneous measurement of both gamma and neutron radiation at low reactor power (2.5 kW). Spectra were collected and analyzed in four different setups in order to study the feasibility of the detector to measure 478 keV prompt gamma photons released from the neutron capture reaction of boron-10. The detector proved to have the required sensitivity to detect and separate the signals from both boron neutron and cadmium neutron capture reactions, which makes it a promising candidate for monitoring the spatial and temporal development of in vivo boron distribution in boron neutron capture therapy. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Implementation of Early Childhood Development Education Service Standard Guidelines on Physical Facilities in Public and Private Early Childhood Education Centres Kakamega County, Kenya

    ERIC Educational Resources Information Center

    Sitati, Emmily M.; Ndirangu, Mwangi; Kennedy, Bota; Rapongo, George S.

    2016-01-01

    In 2006, the Kenyan Ministry of Education (MoE) developed an early childhood development education (ECDE) service standard guidelines to guide the ECDE stakeholders in provision of early childhood education (ECE) programmes. The study sought to investigate the implementation of the ECDE service standard guidelines on provision of physical…

  18. The effect of donor diabetes history on graft failure and endothelial cell density 10 years after penetrating keratoplasty.

    PubMed

    Lass, Jonathan H; Riddlesworth, Tonya D; Gal, Robin L; Kollman, Craig; Benetz, Beth A; Price, Francis W; Sugar, Alan; Terry, Mark A; Soper, Mark; Beck, Roy W

    2015-03-01

    To examine the long-term effect of donor diabetes history on graft failure and endothelial cell density (ECD) after penetrating keratoplasty (PK) in the Cornea Donor Study. Multicenter, prospective, double-masked, controlled clinical trial. One thousand ninety subjects undergoing PK for a moderate risk condition, principally Fuchs' dystrophy or pseudophakic or aphakic corneal edema, were enrolled by 105 surgeons from 80 clinical sites in the United States. Corneas from donors 12 to 75 years of age were assigned by 43 eye banks to participants without respect to recipient factors. Donor and recipient diabetes status was determined from existing medical records. Images of the central endothelium were obtained before surgery (baseline) and at intervals for 10 years after surgery and were analyzed by a central image analysis reading center to determine ECD. Time to graft failure (regraft or cloudy cornea for 3 consecutive months) and ECD. There was no statistically significant association of donor diabetes history with 10-year graft failure, baseline ECD, 10-year ECD, or ECD values longitudinally over time in unadjusted analyses, nor after adjusting for donor age and other significant covariates. The 10-year graft failure rate was 23% in the 199 patients receiving a cornea from a donor with diabetes versus 26% in the 891 patients receiving a cornea from a donor without diabetes (95% confidence interval for the difference, -10% to 6%; unadjusted P=0.60). Baseline ECD (P=0.71), 10-year ECD (P>0.99), and changes in ECD over 10 years (P=0.86) were similar comparing donor groups with and without diabetes. The study results do not suggest an association between donor diabetes and PK outcome. However, the assessment of donor diabetes was imprecise and based on historical data only. The increasing frequency of diabetes in the aging population in the United States affects the donor pool. Thus, the impact of donor diabetes on long-term endothelial health after PK or endothelial keratoplasty, or both, warrants further study with more precise measures of diabetes and its complications. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  19. Modeling the sustainability of a ceramic water filter intervention.

    PubMed

    Mellor, Jonathan; Abebe, Lydia; Ehdaie, Beeta; Dillingham, Rebecca; Smith, James

    2014-02-01

    Ceramic water filters (CWFs) are a point-of-use water treatment technology that has shown promise in preventing early childhood diarrhea (ECD) in resource-limited settings. Despite this promise, some researchers have questioned their ability to reduce ECD incidences over the long term since most effectiveness trials conducted to date are less than one year in duration limiting their ability to assess long-term sustainability factors. Most trials also suffer from lack of blinding making them potentially biased. This study uses an agent-based model (ABM) to explore factors related to the long-term sustainability of CWFs in preventing ECD and was based on a three year longitudinal field study. Factors such as filter user compliance, microbial removal effectiveness, filter cleaning and compliance declines were explored. Modeled results indicate that broadly defined human behaviors like compliance and declining microbial effectiveness due to improper maintenance are primary drivers of the outcome metrics of household drinking water quality and ECD rates. The model predicts that a ceramic filter intervention can reduce ECD incidence amongst under two year old children by 41.3%. However, after three years, the average filter is almost entirely ineffective at reducing ECD incidence due to declining filter microbial removal effectiveness resulting from improper maintenance. The model predicts very low ECD rates are possible if compliance rates are 80-90%, filter log reduction efficiency is 3 or greater and there are minimal long-term compliance declines. Cleaning filters at least once every 4 months makes it more likely to achieve very low ECD rates as does the availability of replacement filters for purchase. These results help to understand the heterogeneity seen in previous intervention-control trials and reemphasize the need for researchers to accurately measure confounding variables and ensure that field trials are at least 2-3 years in duration. In summary, the CWF can be a highly effective tool in the fight against ECD, but every effort should be made by implementing agencies to ensure consistent use and maintenance. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Intermediate-Term Outcomes With Expanded Criteria Deceased Donors in Kidney Transplantation

    PubMed Central

    Stratta, Robert J.; Rohr, Michael S.; Sundberg, Aimee K.; Farney, Alan C.; Hartmann, Erica L.; Moore, Phillip S.; Rogers, Jeffrey; Iskandar, Samy S.; Gautreaux, Michael D.; Kiger, David F.; Doares, William; Anderson, Teresa K.; Hairston, Gloria; Adams, Patricia L.

    2006-01-01

    Objective: To compare intermediate-term outcomes in adult recipients of expanded criteria (ECD) versus concurrent standard criteria (SCD) deceased donor kidney transplants at a single center using a standardized approach. Summary Background Data: Expanded criteria donors (ECDs) are a source of kidneys that increase the donor organ pool, but the value of transplanting these kidneys has been questioned because of concerns regarding diminished survival and predicted poorer intermediate-term outcomes. Methods: Over a 47-month period, we performed 244 deceased donor kidney transplants into adult recipients, including 143 from SCDs and 101 from ECDs. Management algorithms were implemented to preserve nephron function, and recipient selection for an ECD kidney transplant was based on low immunologic risk. All patients received depleting antibody induction in combination with tacrolimus and mycophenolate mofetil. A total of 188 patients (77%) had at least a 1-year follow-up. Results: ECDs were older, had a higher BMI, had an increased incidence of cerebrovascular brain death and preexisting donor hypertension, and had a lower estimated creatinine clearance (CrCl, all P < 0.01) compared with SCDs. Cold ischemic times were similar between groups, but more ECD kidneys were preserved with pulsatile perfusion (P < 0.01). ECD kidney recipients were older, less sensitized, had a lower BMI, had fewer 0-antigen mismatches, and had a shorter waiting time (all P < 0.01) compared with SCD kidney recipients. Actual patient (93%) and kidney graft (83%) survival rates were similar between groups with a mean follow-up of 24 months. The rates of delayed graft function (DGF), acute rejection, readmissions, operative complications, major infections, and resource utilization were comparable between groups. Renal function followed longitudinally was consistently better in SCD patients (P < 0.05). Black recipients had higher rates of DGF, acute rejection, and graft loss (P < 0.05), but the effects were less pronounced in the ECD group. Conclusions: By appropriate donor and recipient profiling and the use of management algorithms to project and protect renal function, excellent intermediate-term outcomes can be achieved with ECD kidney transplants that are comparable to SCD kidney transplants. PMID:16632993

  1. Impact of early graft function on 10-year graft survival in recipients of kidneys from standard- or expanded-criteria donors.

    PubMed

    Smail, Nassima; Tchervenkov, Jean; Paraskevas, Steven; Baran, Dana; Mucsi, Istvan; Hassanain, Mazen; Chaudhury, Prosanto; Cantarovich, Marcelo

    2013-07-27

    The use of kidneys from expanded-criteria donors (ECD) is regarded with caution. We compared 279 kidney transplant recipients (KTxR) from standard-criteria donors (SCD) and 237 from ECD, transplanted between January 1990 and December 2006. We evaluated the impact of immediate graft function (IGF), slow graft function (SGF), and delayed graft function (DGF) and the drop in estimated glomerular filtration rate (ΔeGFR) ≤ 30% or > 30% during the first year after transplantation on long-term patient and death-censored graft survival (DCGS). Ten-year patient survival was similar in SCD- or ECD-KTxR (P = 0.38). DCGS was better in SCD-KTxR versus ECD-KTxR (77.3% vs. 67.3%; P = 0.01). DCGS did not differ in either group experiencing IGF (P = 0.17) or DGF (P = 0.12). However, DCGS was worse in ECD-KTxR experiencing SGF (84.9% vs. 73.7%; P = 0.04). Predictors of DCGS were 1-year serum creatinine (hazard ratio, 1.03; P < 0.0001) and ΔeGFR > 30% between 1 and 12 months (Δ1-12eGFR) after transplantation (hazard ratio, 2.2; P = 0.02). In ECD-KTxR with IGF and more than 1-year follow-up, 10-year DCGS was better in those with Δ1-12eGFR ≤ 30% versus those with Δ1-12eGFR > 30% (83.8% vs. 53.6%; P = 0.01). Recipients of SCD or ECD kidneys with IGF or DGF had similar 10-year patient survival and DCGS. SGF had a worse impact on DCGS in ECD-KTxR. In addition to 1-year serum creatinine, Δ1-12eGFR > 30% is a negative predictor of DCGS. Larger studies should confirm if increasing the use of ECD, avoiding factors that contribute to SGF or DGF, and/or a decline in eGFR during the first year after transplantation may expand the donor pool and result in acceptable long-term outcomes.

  2. The Effect of Donor Diabetes History on Graft Failure and Endothelial Cell Density Ten Years after Penetrating Keratoplasty

    PubMed Central

    Lass, Jonathan H.; Riddlesworth, Tonya D.; Gal, Robin L.; Kollman, Craig; Benetz, Beth A.; Price, Francis W.; Sugar, Alan; Terry, Mark A.; Soper, Mark; Beck, Roy W.

    2014-01-01

    Objective To examine the long term effect of donor diabetes history on graft failure and endothelial cell density (ECD) after penetrating keratoplasty (PKP) in the Cornea Donor Study Design Multi-center prospective, double-masked, controlled clinical trial Participants 1090 subjects undergoing PKP for a moderate risk condition, principally Fuchs’ dystrophy or pseudophakic/aphakic corneal edema (PACE), were enrolled by 105 surgeons from 80 clinical sites in the United States. Methods Corneas from donors 12 to 75 years old were assigned by 43 eye banks to participants without respect to recipient factors. Donor and recipient diabetes status was determined from existing medical records. Images of the central endothelium were obtained preoperatively (baseline) and at intervals for ten years postoperatively and analyzed by a central image analysis reading center to determine ECD. Main Outcome Measure(s) Time to graft failure (regraft or cloudy cornea for 3 consecutive months) and ECD. Results There was no statistically significant association of donor diabetes history with 10-year graft failure, baseline ECD, 10-year ECD or ECD values longitudinally over time in unadjusted analyses nor after adjusting for donor age and other significant covariates. The 10-year graft failure rate was 23% in the 199 cases receiving a cornea from a donor with diabetes versus 26% in the 891 cases receiving a cornea from a donor without diabetes (95% confidence interval for the difference: −10% to +6%; unadjusted p = 0.60). Baseline ECD (p=0.71), 10-year ECD (p>0.99), and changes in ECD over 10 years (p=0.86) were similar comparing donor diabetes and no-diabetes groups. Conclusions and Relevance The study results do not suggest an association between donor diabetes and PKP outcome. However, the assessment of donor diabetes was imprecise and based on historical data only. The increasing frequency of diabetes in the aging population in the United States affects the donor pool, thus the impact of donor diabetes on long term endothelial health after penetrating and/or endothelial keratoplasty warrants further study with more precise measures of diabetes and its complications. Trial Registration clinicaltrials.gov NCT00006411 PMID:25439611

  3. Detector-Response Correction of Two-Dimensional γ -Ray Spectra from Neutron Capture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rusev, G.; Jandel, M.; Arnold, C. W.

    2015-05-28

    The neutron-capture reaction produces a large variety of γ-ray cascades with different γ-ray multiplicities. A measured spectral distribution of these cascades for each γ-ray multiplicity is of importance to applications and studies of γ-ray statistical properties. The DANCE array, a 4π ball of 160 BaF 2 detectors, is an ideal tool for measurement of neutron-capture γ-rays. The high granularity of DANCE enables measurements of high-multiplicity γ-ray cascades. The measured two-dimensional spectra (γ-ray energy, γ-ray multiplicity) have to be corrected for the DANCE detector response in order to compare them with predictions of the statistical model or use them in applications.more » The detector-response correction problem becomes more difficult for a 4π detection system than for a single detector. A trial and error approach and an iterative decomposition of γ-ray multiplets, have been successfully applied to the detector-response correction. As a result, applications of the decomposition methods are discussed for two-dimensional γ-ray spectra measured at DANCE from γ-ray sources and from the 10B(n, γ) and 113Cd(n, γ) reactions.« less

  4. Monitoring environmental pollutants by microchip capillary electrophoresis with electrochemical detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Gang; Lin, Yuehe; Wang, Joseph

    2006-01-15

    This is a review article. During the past decade, significant progress in the development of miniaturized microfluidic systems has Occurred due to the numerous advantages of microchip analysis. This review focuses on recent advances and the key strategies in microchip capillary electrophoresis (CE) with electrochemical detection (ECD) for separating and detecting a variety of environmental pollutants. The subjects covered include the fabrication of microfluidic chips, ECD, typical applications of microchip CE with ECD in environmental analysis, and future prospects. It is expected that microchip CE-ECD will become a powerful tool in the environmental field and will lead to the creationmore » of truly portable devices.« less

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oborn, B. M.; Kolling, S.; Metcalfe, P. E.

    Purpose: A potential side effect of inline MRI-linac systems is electron contamination focusing causing a high skin dose. In this work, the authors reexamine this prediction for an open bore 1 T MRI system being constructed for the Australian MRI-Linac Program. The efficiency of an electron contamination deflector (ECD) in purging electron contamination from the linac head is modeled, as well as the impact of a helium gas region between the deflector and phantom surface for lowering the amount of air-generated contamination. Methods: Magnetic modeling of the 1 T MRI was used to generate 3D magnetic field maps both withmore » and without the presence of an ECD located immediately below the MLC’s. Forty-seven different ECD designs were modeled and for each the magnetic field map was imported into Geant4 Monte Carlo simulations including the linac head, ECD, and a 30 × 30 × 30 cm{sup 3} water phantom located at isocenter. For the first generation system, the x-ray source to isocenter distance (SID) will be 160 cm, resulting in an 81.2 cm long air gap from the base of the ECD to the phantom surface. The first 71.2 cm was modeled as air or helium gas, with the latter encased between two windows of 50 μm thick high density polyethlyene. 2D skin doses (at 70 μm depth) were calculated across the phantom surface at 1 × 1 mm{sup 2} resolution for 6 MV beams of field size of 5 × 5, 10 × 10, and 20 × 20 cm{sup 2}. Results: The skin dose was predicted to be of similar magnitude as the generic systems modeled in previous work, 230% to 1400% ofD {sub max} for 5 × 5 to 20 × 20 cm{sup 2}, respectively. Inclusion of the ECD introduced a nonuniformity to the MRI imaging field that ranged from ∼20 to ∼140 ppm while the net force acting on the ECD ranged from ∼151 N to ∼1773 N. Various ECD designs were 100% efficient at purging the electron contamination into the ECD magnet banks; however, a small percentage were scattered back into the beam and continued to the phantom surface. Replacing a large portion of the extended air-column between the ECD and phantom surface with helium gas is a key element as it significantly minimized the air-generated contamination. When using an optimal ECD and helium gas region, the 70 μm skin dose is predicted to increase moderately inside a small hot spot over that of the case with no magnetic field present for the jaw defined square beams examined here. These increases include from 12% to 40% of D {sub max} for 5 × 5 cm{sup 2}, 18% to 55% of D {sub max} for 10 × 10 cm{sup 2}, and from 23% to 65% of D {sub max} for 20 × 20 cm{sup 2}. Conclusions: Coupling an efficient ECD and helium gas region below the MLCs in the 160 cm isocenter MRI-linac system is predicted to ameliorate the impact electron contamination focusing has on skin dose increases. An ECD is practical as its impact on the MRI imaging distortion is correctable, and the mechanical forces acting on it manageable from an engineering point of view.« less

  6. Electron contamination modeling and reduction in a 1 T open bore inline MRI-linac system.

    PubMed

    Oborn, B M; Kolling, S; Metcalfe, P E; Crozier, S; Litzenberg, D W; Keall, P J

    2014-05-01

    A potential side effect of inline MRI-linac systems is electron contamination focusing causing a high skin dose. In this work, the authors reexamine this prediction for an open bore 1 T MRI system being constructed for the Australian MRI-Linac Program. The efficiency of an electron contamination deflector (ECD) in purging electron contamination from the linac head is modeled, as well as the impact of a helium gas region between the deflector and phantom surface for lowering the amount of air-generated contamination. Magnetic modeling of the 1 T MRI was used to generate 3D magnetic field maps both with and without the presence of an ECD located immediately below the MLC's. Forty-seven different ECD designs were modeled and for each the magnetic field map was imported into Geant4 Monte Carlo simulations including the linac head, ECD, and a 30 × 30 × 30 cm(3) water phantom located at isocenter. For the first generation system, the x-ray source to isocenter distance (SID) will be 160 cm, resulting in an 81.2 cm long air gap from the base of the ECD to the phantom surface. The first 71.2 cm was modeled as air or helium gas, with the latter encased between two windows of 50 μm thick high density polyethlyene. 2D skin doses (at 70 μm depth) were calculated across the phantom surface at 1 × 1 mm(2) resolution for 6 MV beams of field size of 5 × 5, 10 × 10, and 20 × 20 cm(2). The skin dose was predicted to be of similar magnitude as the generic systems modeled in previous work, 230% to 1400% of D(max) for 5 × 5 to 20 × 20 cm(2), respectively. Inclusion of the ECD introduced a nonuniformity to the MRI imaging field that ranged from ∼20 to ∼140 ppm while the net force acting on the ECD ranged from ∼151 N to ∼1773 N. Various ECD designs were 100% efficient at purging the electron contamination into the ECD magnet banks; however, a small percentage were scattered back into the beam and continued to the phantom surface. Replacing a large portion of the extended air-column between the ECD and phantom surface with helium gas is a key element as it significantly minimized the air-generated contamination. When using an optimal ECD and helium gas region, the 70 μm skin dose is predicted to increase moderately inside a small hot spot over that of the case with no magnetic field present for the jaw defined square beams examined here. These increases include from 12% to 40% of [Formula: see text] for 5 × 5 cm(2), 18% to 55% of D(max) for 10 × 10 cm(2), and from 23% to 65% of D(max) for 20 × 20 cm(2). Coupling an efficient ECD and helium gas region below the MLCs in the 160 cm isocenter MRI-linac system is predicted to ameliorate the impact electron contamination focusing has on skin dose increases. An ECD is practical as its impact on the MRI imaging distortion is correctable, and the mechanical forces acting on it manageable from an engineering point of view.

  7. Superconducting Detectors for Study of Infant Universe

    NASA Image and Video Library

    2014-03-17

    The BICEP2 telescope at the South Pole used a specialized array of superconducting detectors to capture polarized light from billions of years ago. The detector array is shown here, under a microscope.

  8. Role of 99mTc-ECD SPECT in the Management of Children with Craniosynostosis

    PubMed Central

    Barik, Mayadhar; Bajpai, Minu; Das, Rashmi Ranajn; Malhotra, Arun; Panda, Shasanka Shekhar; Sahoo, Manas Kumar; Dwivedi, Sadanand

    2014-01-01

    Purpose of the Report. There is a paucity of data on correlation of various imaging modalities with clinical findings in craniosynostosis. Moreover, no study has specifically reported the role of 99mTc-ECD SPECT in a large number of subjects with craniosynostosis. Materials and Methods. We prospectively analyzed a cohort of 85 patients with craniosynostosis from year 2007 to 2012. All patients underwent evaluation with 99mTc-ECD SPECT and the results were correlated with radiological and surgical findings. Results. 99mTc-ECD SPECT revealed regional perfusion abnormalities in the cerebral hemisphere corresponding to the fused sutures preoperatively that disappeared postoperatively in all the cases. Corresponding to this, the mean mental performance quotient (MPQ) increased significantly (P < 0.05) postoperatively only in those children with absent perfusion defect postoperatively. Conclusions. Our study suggests that early surgery and release of craniosynostosis in patients with preoperative perfusion defects (absent on 99mTc-ECD SPECT study) are beneficial, as theylead to improved MPQ after surgery. PMID:24987670

  9. Further evidence of psychological factors underlying choice of elective cesarean delivery (ECD) by primigravidae.

    PubMed

    Matinnia, Nasrin; Haghighi, Mohammad; Jahangard, Leila; Ibrahim, Faisal B; Rahman, Hejar A; Ghaleiha, Ali; Holsboer-Trachsler, Edith; Brand, Serge

    2018-01-01

    Requests for elective cesarean delivery (ECD) have increased in Iran. While some sociodemographic and fear-related factors have been linked with this choice, psychological factors such as self-esteem, stress, and health beliefs are under-researched. A total of 342 primigravidae (mean age = 25 years) completed questionnaires covering psychological dimensions such as self-esteem, perceived stress, marital relationship quality, perceived social support, and relevant health-related beliefs. Of the sample, 214 (62.6%) chose to undergo ECD rather than vaginal delivery (VD). This choice was associated with lower self-esteem, greater perceived stress, belief in higher susceptibility to problematic birth and barriers to an easy birth, along with lower perceived severity of ECD, fewer perceived benefits from VD, lower self-efficacy and a lower feeling of preparedness. No differences were found for marital relationship quality or perceived social support. The pattern suggests that various psychological factors such as self-esteem, self-efficacy, and perceived stress underpin the decision by primigravidae to have an ECD.

  10. Structural insights of ZIP4 extracellular domain critical for optimal zinc transport

    NASA Astrophysics Data System (ADS)

    Zhang, Tuo; Sui, Dexin; Hu, Jian

    2016-06-01

    The ZIP zinc transporter family is responsible for zinc uptake from the extracellular milieu or intracellular vesicles. The LIV-1 subfamily, containing nine out of the 14 human ZIP proteins, is featured with a large extracellular domain (ECD). The critical role of the ECD is manifested by disease-causing mutations on ZIP4, a representative LIV-1 protein. Here we report the first crystal structure of a mammalian ZIP4-ECD, which reveals two structurally independent subdomains and an unprecedented dimer centred at the signature PAL motif. Structure-guided mutagenesis, cell-based zinc uptake assays and mapping of the disease-causing mutations indicate that the two subdomains play pivotal but distinct roles and that the bridging region connecting them is particularly important for ZIP4 function. These findings lead to working hypotheses on how ZIP4-ECD exerts critical functions in zinc transport. The conserved dimeric architecture in ZIP4-ECD is also demonstrated to be a common structural feature among the LIV-1 proteins.

  11. Neutron Capture Experiments Using the DANCE Array at Los Alamos

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dashdorj, D.; MonAme Scientific Research Center, Ulaanbaatar; Mitchell, G. E.

    2009-03-31

    The Detector for Advanced Neutron Capture Experiments (DANCE) is designed for neutron capture measurements on very small and/or radioactive targets. The DANCE array of 160 BaF{sub 2} scintillation detectors is located at the Lujan Center at the Los Alamos Neutron Science Center (LANSCE). Accurate measurements of neutron capture data are important for many current applications as well as for basic understanding of neutron capture. The gamma rays following neutron capture reactions have been studied by the time-of-flight technique using the DANCE array. The high granularity of the array allows measurements of the gamma-ray multiplicity. The gamma-ray multiplicities and energy spectramore » for different multiplicities can be measured and analyzed for spin and parity determination of the resolved resonances.« less

  12. Early Childhood Development through an Integrated Program: Evidence from the Philippines. Impact Evaluation Series No. 2. World Bank Policy Research Working Paper 3922-IE

    ERIC Educational Resources Information Center

    Armecin, Graeme; Behrman, Jere R.; Ghuman, Sharon; Gultiano, Socorro; King, Elizabeth M.; Lee, Nanette

    2006-01-01

    More attention and resources have been devoted in recent years to early childhood development (ECD) in low- and middle-income countries. Rigorous studies on the effectiveness of ECD-related programs for improving children's development in various dimensions in the developing world are scant. The authors evaluate an important ECD initiative of the…

  13. Correlation of E-cadherin expression with differentiation grade and histological type in breast carcinoma.

    PubMed Central

    Gamallo, C.; Palacios, J.; Suarez, A.; Pizarro, A.; Navarro, P.; Quintanilla, M.; Cano, A.

    1993-01-01

    Recently, a correlation has been suggested between a loss of E-cadherin (E-CD) and increased invasiveness of neoplastic cells. In this study, E-CD expression in breast cancer was investigated using an affinity-purified antibody (ECCD-2) in an immunoenzymatic (avidin-biotin-alkaline phosphatase) test. Intensity and extension of E-CD immunoreactivity were evaluated in 61 breast carcinomas and correlated with their histological type and grade, nodal involvement, and hormonal receptor status. Histological types were infiltrating ductal carcinoma of no special type (n = 54) and infiltrating lobular carcinoma (n = 7). All infiltrating ductal carcinomas of no special type except two grade 3 carcinomas showed positive immunoreactivity that was variable among different cases. Grade 1 breast carcinomas (n = 10) showed greater immunoreactivity than grade 2 (n = 25) and grade 3 (n = 19) carcinomas. E-CD immunoreactivity correlated positively with the degree of tubular formation and inversely with the mitoses number. None of the infiltrating lobular carcinomas expressed E-CD in their infiltrating cells, whereas they showed only weak immunostains in areas of atypical lobular hyperplasia and lobular carcinoma in situ. These results indicate that E-CD expression correlates with histological type and grade in breast carcinomas. Images Figure 1 Figure 2 Figure 3 PMID:7682767

  14. Effect of laser peripheral iridotomy using argon and neodymium-YAG lasers on corneal endothelial cell density: 7-year longitudinal evaluation.

    PubMed

    Ono, Takashi; Iida, Masaharu; Sakisaka, Toshihiro; Minami, Keiichiro; Miyata, Kazunori

    2018-03-01

    To evaluate the changes in corneal endothelial cell density (ECD) over a 7-year period after laser peripheral iridotomy (LPI) using argon and neodymium-doped yttrium aluminum garnet (Nd:YAG) lasers. Retrospective case series. Eyes that underwent prophylactic LPI using argon and Nd:YAG lasers were followed up for 7 years. Central corneal endothelial cells were observed by use of noncontact specular microscopy preoperatively and at 1 and 7 years postoperatively. Changes in ECD and the associations between preoperative ECD and the total energy of the Nd:YAG laser were evaluated. Fifty-one eyes of 51 patients were followed up for 7 years. The ECD significantly decreased after LPI (P < 0.049), and the reduction rate at 1 year after the surgery (1.69 ± 4.80%, 95% CI: 0.34%-3.04%) was significantly higher than the annual reduction rates after 1 year (0.17 ± 0.85%/y, P = 0.036, 95% CI: -0.07% to 0.41%). No association was found between the preoperative ECD and the total laser energy. Long-term evaluation indicated that the reduction in ECD after argon-Nd:YAG laser LPI was present but small during the initial year and was negligible after 1 year.

  15. Radiographic absence of the posterior communicating arteries and the prediction of cognitive dysfunction after carotid endarterectomy.

    PubMed

    Sussman, Eric S; Kellner, Christopher P; Mergeche, Joanna L; Bruce, Samuel S; McDowell, Michael M; Heyer, Eric J; Connolly, E Sander

    2014-09-01

    Approximately 25% of patients exhibit cognitive dysfunction 24 hours after carotid endarterectomy (CEA). One of the purported mechanisms of early cognitive dysfunction (eCD) is hypoperfusion due to inadequate collateral circulation during cross-clamping of the carotid artery. The authors assessed whether poor collateral circulation within the circle of Willis, as determined by preoperative CT angiography (CTA) or MR angiography (MRA), could predict eCD. Patients who underwent CEA after preoperative MRA or CTA imaging and full neuropsychometric evaluation were included in this study (n = 42); 4 patients were excluded due to intraoperative electroencephalographic changes and subsequent shunt placement. Thirty-eight patients were included in the statistical analyses. Patients were stratified according to posterior communicating artery (PCoA) status (radiographic visualization of at least 1 PCoA vs of no PCoAs). Variables with p < 0.20 in univariate analyses were included in a stepwise multivariate logistic regression model to identify predictors of eCD after CEA. Overall, 23.7% of patients exhibited eCD. In the final multivariate logistic regression model, radiographic absence of both PCoAs was the only independent predictor of eCD (OR 9.64, 95% CI 1.43-64.92, p = 0.02). The absence of both PCoAs on preoperative radiographic imaging is predictive of eCD after CEA. This finding supports the evidence for an underlying ischemic etiology of eCD. Larger studies are justified to verify the findings of this study. Clinical trial registration no.: NCT00597883 ( http://www.clinicaltrials.gov ).

  16. Early Childhood Diarrhea Predicts Cognitive Delays in Later Childhood Independently of Malnutrition

    PubMed Central

    Pinkerton, Relana; Oriá, Reinaldo B.; Lima, Aldo A. M.; Rogawski, Elizabeth T.; Oriá, Mônica O. B.; Patrick, Peter D.; Moore, Sean R.; Wiseman, Benjamin L.; Niehaus, Mark D.; Guerrant, Richard L.

    2016-01-01

    Understanding the complex relationship between early childhood infectious diseases, nutritional status, poverty, and cognitive development is significantly hindered by the lack of studies that adequately address confounding between these variables. This study assesses the independent contributions of early childhood diarrhea (ECD) and malnutrition on cognitive impairment in later childhood. A cohort of 131 children from a shantytown community in northeast Brazil was monitored from birth to 24 months for diarrhea and anthropometric status. Cognitive assessments including Test of Nonverbal Intelligence (TONI), coding tasks (WISC-III), and verbal fluency (NEPSY) were completed when children were an average of 8.4 years of age (range = 5.6–12.7 years). Multivariate analysis of variance models were used to assess the individual as well as combined effects of ECD and stunting on later childhood cognitive performance. ECD, height for age (HAZ) at 24 months, and weight for age (WAZ) at 24 months were significant univariate predictors of the studies three cognitive outcomes: TONI, coding, and verbal performance (P < 0.05). Multivariate models showed that ECD remained a significant predictor, after adjusting for the effect of 24 months HAZ and WAZ, for both TONI (HAZ, P = 0.029 and WAZ, P = 0.006) and coding (HAZ, P = 0.025 and WAZ, P = 0.036) scores. WAZ and HAZ were also significant predictors after adjusting for ECD. ECD remained a significant predictor of coding (WISC III) after number of household income was considered (P = 0.006). This study provides evidence that ECD and stunting may have independent effects on children's intellectual function well into later childhood. PMID:27601523

  17. Cataract surgery in eyes with low corneal endothelial cell density.

    PubMed

    Hayashi, Ken; Yoshida, Motoaki; Manabe, Shin-ichi; Hirata, Akira

    2011-08-01

    To compare corneal endothelial damage after cataract surgery in eyes with low endothelial cell density (ECD) and eyes with normal ECD. Hayashi Eye Hospital, Fukuoka, Japan. Case-control study. Cataract surgery was performed in eyes with a low ECD (500 to 1000 cells/mm(2)) (low-density group) and control eyes with a normal ECD. The ECD and central corneal thickness (CCT) were measured preoperatively and 1 and 3 months postoperatively, and the percentage cell loss and increase in CCT were compared. The low-density group and control group each comprised 50 eyes. In the low-density group, 39 eyes had nonprogressive endothelial pathology and 11 had Fuchs dystrophy. The mean ECD was significantly less and the CCT significantly greater in the low-density group than in the control group throughout the follow-up (P ≤.0066). However, no significant difference in the percentage of cell loss was found between groups at 1 or 3 months (5.1%, low-density group; 4.2%, control group) (P ≥.1477). The percentage increase in CCT was significantly greater in the low-density group than in the control group at 1 month (P<.0001), although there was no significant difference at 3 months (0.4% and -0.4%, respectively) (P=.2172). Corneal endothelial damage after cataract surgery in eyes with low ECD was slight and comparable to that in healthy eyes, which suggests that cataract surgery alone (without corneal transplantation) should be performed first. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. The extracellular domain of Her2 in serum as a biomarker of breast cancer.

    PubMed

    Perrier, Alexandre; Gligorov, Joseph; Lefèvre, Guillaume; Boissan, Mathieu

    2018-02-28

    Breast cancer is a major health problem worldwide. In ~15% of breast cancers, the epidermal growth factor receptor HER2, a transmembrane protein, is overexpressed. This HER2 overexpression is associated with an aggressive form of the disease and a poor clinical prognosis. The extracellular domain (ECD) of HER2 is released into the blood by a proteolytic mechanism known as "ECD shedding". This proteolytic shedding leaves a constitutively active truncated receptor in the membrane that is 10-100-fold more oncogenic than the full-length receptor and promotes the growth and survival of cancer cells. Shedding of the HER2 ECD is increased during metastasis: whereas 15% of primary breast cancer patients have elevated levels of serum HER2 ECD (sHER2 ECD), the levels reach 45% in patients with metastatic disease. Thus, sHER2 ECD has been proposed as a promising biomarker for cancer recurrence and for monitoring the disease status of patients overexpressing HER2. Nevertheless, in 2016, the American Society of Clinical Oncology advises clinicians not to use soluble HER2 levels to guide their choice of adjuvant therapy for patients with HER2-positive breast cancer, because the evidence was considered not strong enough. Currently, biomarkers such as carcinoembryonic antigen and cancer antigen 15-3 are widely used to monitor metastatic breast cancer disease even if the level of evidence of clinical impact of this monitoring is poor. In this article, we review the evidence that sHER2 ECD might be used in some situations as a biomarker for breast cancer. Although this serum biomarker will not replace the direct measurement of tumor HER2 status for diagnosis of early-stage tumors; it might be especially useful in metastatic disease for prognosis, as an indicator of cancer progression and of therapy response, particularly to anti-HER2 therapies. Owing to these data, sHER2 ECD should be considered as a promising biomarker to detect cancer recurrence and metastasis.

  19. Estrogenic effect of leachates and soil extracts from lysimeters spiked with sewage sludge and reference endocrine disrupters.

    PubMed

    Dizer, Halim; Fischer, Birgit; Sepulveda, Isabel; Loffredo, Elisabetta; Senesi, Nicola; Santana, Fernando; Hansen, Peter-D

    2002-01-01

    Several experiments were conducted to evaluate the behavior and performance of some potential endocrine disrupters (ECDs). Two in vitro screening assays, one based on MCF7-cell proliferation (E-screen test) and the other on estrogenic receptor activity [enzyme-linked receptor assay (ELRA)], were used for the tests, which were done in lysimeters 80 cm in diameter with depth of 30 cm (shallow) or 90 cm (deep). A sandy soil was used to fill in all lysimeters, which were spiked on the surface with either: (a) a sewage sludge (SS) at a dose equivalent to 20 tons ha-1; (b) a mixture of reference ECDs, comprising 17 alpha- and 17 beta-estradiol (E2), nonylphenol, octylphenol, and bisphenol A at doses 100 times higher than the maximum concentrations respectively found in the applied SS; or (c) a mixture of ECDs and SS. After percolation of the lysimeters with rain and/or artificial water, five leachates were sampled from each lysimeter during a period of 210 days. Immediately after the lysimeter percolation experiments, four and six soil fractions were dissected from, respectively, the 30-cm and 90-cm lysimeters and extracted by water. Both the leachate and soil extract samples were analyzed for their estrogenicity using the assays indicated above. The E-screen assay was highly sensitive only for some leachate and extract samples but gave no response for most leachates and soil extracts. The results of the ELRA assay suggests a significantly higher estrogenicity of leachate samples from shallow lysimeters compared with that of leachates from deep lysimeters. In contrast, the estrogenic effect measured for soil extracts of shallow lysimeters was lower than that measured for soil extracts of deep lysimeters. The results of the E-screen assay suggests the occurrence of a fast mobilization of applied ECDs and a moderate retardation effect of native ECDs contained in applied SS in the sandy soil used in the lysimeters. In lysimeters spiked with a mixture of SS and ECDs, the washing-out effect of ECDs in the first leachate fraction decreased, but the distribution of ECDs in the lysimeters increased. The relatively high estrogenic impact measured for soil water extracts suggests that the ECDs were mostly associated with water-soluble fractions of organic matter and/or water-suspended fractions of the mineral soil matrix. The application of SS to agricultural and forest fields may determine the immobilization of ECDs in soil or their movement to surface and/or groundwater. Therefore, an endocrine risk of exposure exists for the water and soil organisms.

  20. Amphetamine manipulates monoamine oxidase-A level and behavior using theranostic aptamers of transcription factors AP-1/NF-kB.

    PubMed

    Liu, Christina H; Ren, Jiaqian; Liu, Philip K

    2016-02-03

    Monoamine oxidase (MAO) enzymes play a critical role in controlling the catabolism of monoamine neurotransmitters and biogenic trace amines and behavior in humans. However, the mechanisms that regulate MAO are unclear. Several transcription factor proteins are proposed to modulate the transcription of MAO gene, but evidence supporting these hypotheses is controversial. We aimed to investigate the mechanism of gene transcription regulator proteins on amphetamine-induced behavior. We applied aptamers containing a DNA binding sequence, as well as a random sequence (without target) to study the modulation of amphetamine-induced MAO levels and hyperactivity in living mice. We pretreated in adult male C57black6 mice (Taconic Farm, Germantown, NY) (n ≥ 3 litters at a time), 2 to 3 months of age (23 ± 2 gm body weight) with double-stranded (ds) DNA aptamers with sequence specific to activator protein-1 (5ECdsAP1), nuclear factor-kappa beta (5ECdsNF-kB), special protein-1 (5ECdsSP-1) or cyclicAMP responsive element binding (5ECdsCreB) protein binding regions, 5ECdsRan [a random sequence without target], single-stranded AP-1 (5ECssAP-1) (8 nmol DNA per kg) or saline (5 μl, intracerebroventricular [icv] injection) control before amphetamine administration (4 mg/kg, i.p.). We then measured and analyzed locomotor activities and the level of MAO-A and MAO-B activity. In the pathological condition of amphetamine exposure, we showed here that pretreatment with 5ECdsAP1 and 5ECdsNF-kB reversed the decrease of MAO-A activity (p < 0.05, t test), but not activity of the B isomer (MAO-B), in the ventral tegmental area (VTA) and substantia nigra (SN) of C57black6 mice. The change in MAO-A level coincided with a reversed amphetamine-induced restless behavior of mice. Pretreatments with saline, 5ECdsCreB, 5ECdsSP-1, 5ECdsRan or 5ECssAP-1 had no effect. Our data lead us to conclude that elevation of AP-1 or NF-kB indirectly decreases MAO-A protein levels which, in turn, diminishes MAO-A ability in the VTA of the mesolimbic dopaminergic pathway that has been implicated in cells under stress especially in the SN and VTA. This study has implications for design for the treatment of drug exposure and perhaps Parkinson's dementia.

  1. Limit on the radiative neutrinoless double electron capture of ^{36}Ar from GERDA Phase I

    NASA Astrophysics Data System (ADS)

    Agostini, M.; Allardt, M.; Bakalyarov, A. M.; Balata, M.; Barabanov, I.; Barros, N.; Baudis, L.; Bauer, C.; Bellotti, E.; Belogurov, S.; Belyaev, S. T.; Benato, G.; Bettini, A.; Bezrukov, L.; Bode, T.; Borowicz, D.; Brudanin, V.; Brugnera, R.; Caldwell, A.; Cattadori, C.; Chernogorov, A.; D'Andrea, V.; Demidova, E. V.; di Vacri, A.; Domula, A.; Doroshkevich, E.; Egorov, V.; Falkenstein, R.; Fedorova, O.; Freund, K.; Frodyma, N.; Gangapshev, A.; Garfagnini, A.; Gooch, C.; Grabmayr, P.; Gurentsov, V.; Gusev, K.; Hakenmüller, J.; Hegai, A.; Heisel, M.; Hemmer, S.; Heusser, G.; Hofmann, W.; Hult, M.; Inzhechik, L. V.; Csáthy, J. Janicskó; Jochum, J.; Junker, M.; Kazalov, V.; Kihm, T.; Kirpichnikov, I. V.; Kirsch, A.; Kish, A.; Klimenko, A.; Kneißl, R.; Knöpfle, K. T.; Kochetov, O.; Kornoukhov, V. N.; Kuzminov, V. V.; Laubenstein, M.; Lazzaro, A.; Lebedev, V. I.; Lehnert, B.; Liao, H. Y.; Lindner, M.; Lippi, I.; Lubashevskiy, A.; Lubsandorzhiev, B.; Lutter, G.; Macolino, C.; Majorovits, B.; Maneschg, W.; Medinaceli, E.; Miloradovic, M.; Mingazheva, R.; Misiaszek, M.; Moseev, P.; Nemchenok, I.; Palioselitis, D.; Panas, K.; Pandola, L.; Pelczar, K.; Pullia, A.; Riboldi, S.; Rumyantseva, N.; Sada, C.; Salamida, F.; Salathe, M.; Schmitt, C.; Schneider, B.; Schönert, S.; Schreiner, J.; Schütz, A.-K.; Schulz, O.; Schwingenheuer, B.; Selivanenko, O.; Shirchenko, M.; Simgen, H.; Smolnikov, A.; Stanco, L.; Stepaniuk, M.; Vanhoefer, L.; Vasenko, A. A.; Veresnikova, A.; von Sturm, K.; Wagner, V.; Walter, M.; Wegmann, A.; Wester, T.; Wiesinger, C.; Wilsenach, H.; Wojcik, M.; Yanovich, E.; Zhitnikov, I.; Zhukov, S. V.; Zinatulina, D.; Zuber, K.; Zuzel, G.

    2016-12-01

    Neutrinoless double electron capture is a process that, if detected, would give evidence of lepton number violation and the Majorana nature of neutrinos. A search for neutrinoless double electron capture of ^{36}Ar has been performed with germanium detectors installed in liquid argon using data from Phase I of the GERmanium Detector Array ( Gerda) experiment at the Gran Sasso Laboratory of INFN, Italy. No signal was observed and an experimental lower limit on the half-life of the radiative neutrinoless double electron capture of ^{36}Ar was established: T_{1/2} > 3.6 × 10^{21} years at 90% CI.

  2. Limit on the radiative neutrinoless double electron capture of 36Ar from GERDA Phase I

    DOE PAGES

    Agostini, M.; Allardt, M.; Bakalyarov, A. M.; ...

    2016-11-28

    Neutrinoless double electron capture is a process that, if detected, would give evidence of lepton number violation and the Majorana nature of neutrinos. Here, a search for neutrinoless double electron capture of 36Ar has been performed with germanium detectors installed in liquid argon using data from Phase I of the GERmanium Detector Array (Gerda) experiment at the Gran Sasso Laboratory of INFN, Italy. No signal was observed and an experimental lower limit on the half-life of the radiative neutrinoless double electron capture of 36 Ar was established: T 1/2 > 3.6 × 10 21 years at 90% CI.

  3. How and How Much Molecular Conformation Affects Electronic Circular Dichroism: The Case of 1,1-Diarylcarbinols.

    PubMed

    Padula, Daniele; Pescitelli, Gennaro

    2018-01-09

    Chiroptical spectra such as electronic circular dichroism (ECD) are said to be much more sensitive to conformation than their non-chiroptical counterparts, however, it is difficult to demonstrate such a common notion in a clear-cut way. We run DFT and TDDFT calculations on two closely related 1,1-diarylmethanols which show mirror-image ECD spectra for the same absolute configuration. We demonstrate that the main reason for the different chiroptical response of the two compounds lies in different conformational ensembles, caused by a single hydrogen-to-methyl substitution. We conclude that two compounds, having the same configuration but different conformation, may exhibit mirror-image ECD signals, stressing the importance and impact of conformational factors on ECD spectra.

  4. Headaches as a presenting symptom of linear morphea en coup de sabre.

    PubMed

    Polcari, Ingrid; Moon, Amanda; Mathes, Erin F; Gilmore, Elaine S; Paller, Amy S

    2014-12-01

    Linear morphea en coup de sabre (ECDS) is a form of localized scleroderma that predominantly affects the pediatric population, with a median age of 10 years at presentation. The existence of neurologic findings in association with ECDS has been well described in the literature. Here we describe 4 patients with ECDS who presented with headaches, which were typical migraines in 3 of the patients. The headaches preceded the onset of cutaneous findings by at least 6 months. Our patients' cases emphasize both the importance of recognizing headaches as a harbinger of ECDS and the necessity of performing thorough cutaneous examination in patients with unexplained headaches or other neurologic disease. Copyright © 2014 by the American Academy of Pediatrics.

  5. Simultaneous determination of traces of pyrethroids, organochlorines and other main plant protection agents in agricultural soils by headspace solid-phase microextraction-gas chromatography.

    PubMed

    Fernandez-Alvarez, Maria; Llompart, Maria; Lamas, J Pablo; Lores, Marta; Garcia-Jares, Carmen; Cela, Rafael; Dagnac, Thierry

    2008-04-25

    A solvent-free and simple method based on headspace solid-phase microextraction (HS-SPME) was developed in order to determine simultaneously 36 common pesticides and breakdown products (mostly pyrethroids and organochlorine compounds) in soil. The analysis was carried out by gas chromatography with micro-electron-capture detection (GC-microECD). As far as we know, this is the first study about the SPME of pyrethroid insecticides from soil. Factors such as extraction temperature, matrix modification by addition of water, salt addition (% NaCl) and fiber coating were considered in the optimization of the HS-SPME. To this end, a 3 x 2(3-1) fractional factorial design was performed. The results showed that temperature and fiber coating were the most significant variables affecting extraction efficiency. A suitable sensitivity for all investigated compounds was achieved at 100 degrees C by extracting soil samples wetted with 0.5 mL of ultrapure water (0% NaCl) employing a polyacrylate (PA) coating fiber. Using the recommended extraction conditions with GC-microECD, a linear calibration could be achieved over a range of two orders of magnitude for both groups of analytes. Limits of detection (LODS) at the sub-ng g(-1) level were attained and relative standard deviations (RSDs) were found to be lower than 14% for both groups of pesticides. Matrix effects were investigated by the analysis of different soil samples fortified with the target compounds. The method accuracy was assessed and good recovery values (>70%, in most cases) were obtained. The method was also validated with a certified reference material (RTC-CRM818-050), which was quantified using a standard addition protocol. Finally, the proposed HS-SPME-GC-microECD methodology was further applied to the screening of environmental soil samples for the presence of the target pesticides.

  6. Validation of a QuEChERS-based gas chromatographic method for analysis of pesticide residues in Cassia angustifolia (senna).

    PubMed

    Tripathy, Vandana; Saha, Ajoy; Patel, Dilipkumar J; Basak, B B; Shah, Paresh G; Kumar, Jitendra

    2016-08-02

    A simple multi-residue method based on modified QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) approach was established for the determination of 17 organochlorine (OC), 15 organophosphorous (OP) and 7 synthetic pyrethroid (SP) pesticides in an economically important medicinal plant of India, Senna (Cassia angustifolia), by gas chromatography coupled to electron capture and flame thermionic detectors (GC/ECD/FTD) and confirmation of residues was done on gas chromatograph coupled with mass spectrometry (GC-MS). The developed method was validated by testing the following parameters: linearity, limit of detection (LOD), limit of quantification (LOQ), matrix effect, accuracy-precision and measurement uncertainty; the validation study clearly demonstrated the suitability of the method for its intended application. All pesticides showed good linearity in the range 0.01-1.0 μg mL(-1) for OCs and OPs and 0.05-2.5 μg mL(-1) for SPs with correlation coefficients higher than 0.98. The method gave good recoveries for most of the pesticides (70-120%) with intra-day and inter-day precision < 20% in most of the cases. The limits of detection varied from 0.003 to 0.03 mg kg(-1), and the LOQs were determined as 0.01-0.049 mg kg(-1). The expanded uncertainties were <30%, which was distinctively less than a maximum default value of ±50%. The proposed method was successfully applied to determine pesticide residues in 12 commercial market samples obtained from different locations in India.

  7. Assessment of the chlorinated hydrocarbons residues contamination in edible mushrooms from the North-Eastern part of Poland.

    PubMed

    Gałgowska, Michalina; Pietrzak-Fiećko, Renata; Felkner-Poźniakowska, Barbara

    2012-11-01

    The aim of the study was to determine the content of chlorinated hydrocarbon residues in edible mushrooms from the north-eastern part of Poland. Material consisted of two species of fungi: Xerocomus mushrooms (Xerocomus badius), Boletus mushrooms (Boletus edulis). The dried samples (cups and cut-up material) were extracted with Soxhlet method in order to obtain lipid substances. In the fat chlorinated hydrocarbons were determined by Ludwicki et al. (1996) method. The separation and quantitative determination of DDT, DDE, DDD and γ-HCH were conducted with the method of gas chromatography using an electron capture detector - ECD. In all tested samples the presence of γ-HCH, DDT and its metabolites (DDE, DDD) was detected. The higher content of γ-HCH was found in Xerocomus mushrooms (average 0.125 μg/kg of mushrooms); in the Boletus mushrooms -0.11 μg/kg of mushrooms. The content of ΣDDT in cups of Xerocomus mushrooms was more than 2-fold higher than in those of Boletus mushrooms (3.78:1.71 mg/kg of mushrooms). The opposite relationship was observed for cut-up material. The higher concentration of ΣDDT was found in Boletus mushrooms (2.26 mg/kg of mushrooms) while in Xerocomus mushrooms this content was 0.91 mg/kg of mushrooms. Despite the fact that chlorinated hydrocarbons were determined in all samples under study, their contents do not exceed acceptable levels indicating that the consumption of mushrooms does not pose a health risk to consumers from the organochlorine compounds. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Spatial distributions and seasonal variations of organochlorine pesticides in water and soil samples in Bolu, Turkey.

    PubMed

    Karadeniz, Hatice; Yenisoy-Karakaş, Serpil

    2015-03-01

    In this study, a total of 75 water samples (38 groundwater and 37 surface water samples) and 54 surface soil samples were collected from the five districts of Bolu, which is located in the Western Black Sea Region of Turkey in the summer season of 2009. In the autumn season, 17 water samples (surface water and groundwater samples) and 17 soil samples were collected within the city center to observe the seasonal changes of organochlorine pesticides (OCPs). Groundwater and surface water samples were extracted using solid phase extraction. Soil samples were extracted ultrasonically. Sixteen OCP compounds in the standard solution were detected by a gas chromatography-electron capture detector (GC-ECD). Therefore, the method validation was performed for those 16 OCP compounds. However, 13 OCP compounds could be observed in the samples. The concentrations of most OCPs were higher in samples collected in the summer than those in the autumn. The most frequently observed pesticides were endosulfan sulfate and 4,4'-dichlorodiphenyltrichloroethane (DDT) in groundwater samples, α-HCH in surface water samples, and endosulfan sulfate in soil samples. The average concentration of endosulfan sulfate was the highest in water and soil samples. Compared to the literature values, the average concentrations in this study were lower values. Spatial distribution of OCPs was evaluated with the aid of contour maps for the five districts of Bolu. Generally, agricultural processes affected the water and soil quality in the region. However, non-agricultural areas were also affected by pesticides. The concentrations of pesticides were below the legal limits of European directives for each pesticide.

  9. Organochlorine pesticide residues in dried cocoa beans obtained from cocoa stores at Ondo and Ile-Ife, Southwestern Nigeria.

    PubMed

    Oyekunle, J A O; Akindolani, O A; Sosan, M B; Adekunle, A S

    2017-01-01

    Levels of organochlorine pesticides (OCPs) were determined in dried cocoa beans obtained from cocoa produce stores at Ondo and Ile-Ife, Southwestern Nigeria. Cocoa beans samples were sun dried to a constant weight, pulverized and soxhlet extracted with dichloromethane to obtain the OCPs. Qualitative identification and quantitative evaluation of the extracted OCPs after clean-up on silica gel were accomplished with the aid of a Gas Chromatography coupled with an Electron Capture Detector (GC-ECD). Levels of OCPs in cocoa beans from Ondo had a mean range of ND (p, p'-DDE) to 82.17 ± 54.53 ng/g (p, p'-DDT) were higher than the OCPs levels in cocoa beans from Ile-Ife with a mean range of 0.37 ± 0.63 ng/g (Endrin) to 57.76 ± 81.48 ng/g (p, p'-DDT). The higher levels of OCPs detected in the cocoa beans from Ondo could be an indication of higher volume of OCPs application by cocoa farmers in Ondo and its environs since cocoa plantations were more concentrated than Ile-Ife environs. Levels of OCPs determined in the cocoa beans were within the Maximum Residue Limit (MRLs) for OCPs set by the World Health Organization/Food and Agricultural Organization. The study established the presence of OCPs in an important crop of Nigeria. Hence, there is the need to keep monitoring ecotoxicological chemical substances in agricultural food products of Nigeria so as to take steps that ensure health safety of end users.

  10. Analysis of phenolic acids by ionic liquid-in-water microemulsion liquid chromatography coupled with ultraviolet and electrochemical detector.

    PubMed

    Peng, Li-Qing; Cao, Jun; Du, Li-Jing; Zhang, Qi-Dong; Shi, Yu-Tin; Xu, Jing-Jing

    2017-05-26

    An environmentally friendly ionic liquid-in-water (IL/W) microemulsion was established and applied as mobile phase in microemulsion liquid chromatography (MELC) with ultraviolet (UV) detection or electrochemical detector (ECD) for analysis of phenolic compounds in real samples. The optimal condition of the method was using the best composition of microemulsion (0.2% w/v [HMIM]PF 6 , 1.0% w/v SDS, 3.0% w/v n-butanol, 95.8% v/v water, pH 2.5) with UV detection. The validation results indicated that the method provided high degree of sensitivity, precision and accuracy with the low limit of detections ranged from 17.9-238ng/mL, satisfactory mean recovery values in the range of 80.1-105% and good linearity (r 2 >0.9994). Additionally, this method exhibited high selectivity and resolution for the analytes and was more eco-friendly compared with traditional MELC method. Consequently, the established IL/W MELC method was successfully applied to simultaneously separate and determine target compounds in Danshen sample and its preparation. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Risk factors for donor endothelial loss in eye bank-prepared posterior lamellar corneal tissue for descemet stripping automated endothelial keratoplasty.

    PubMed

    Liu, Yu-Chi; Alvarez Paraz, Carisa M; Cajucom-Uy, Howard Yu; Agahari, Djoni; Sethuraman, Selvam; Tan, Donald T-H; Mehta, Jodhbir S

    2014-07-01

    The aim of this study was to investigate donor, tissue, and precut procedure risk factors for endothelial cell density (ECD) loss in posterior lamellar corneal tissue preparation by an eye bank for Descemet stripping automated endothelial keratoplasty. A total of 259 corneoscleral rims precut by the Singapore Eye Bank from October 2011 to August 2013 were evaluated. Donor characteristics, tissue characteristics, and precut procedure parameters were analyzed. The mean donor age was 57.18 ± 11.35 years, and the mean cutting transition time was 4.16 ± 0.75 seconds. The mean ECD was 2826 ± 225 and 2787 ± 224 cells per square millimeter before and after precutting, respectively, with an average ECD change of -1.38% ± 3.28%. The precutting procedure failure rate was 1.2%. Mutivariate regression analysis showed that an older donor age, a higher ECD before cutting, and a slower cutting transition speed were significant factors. Corneas with an ECD >2800 cells per square millimeter before precutting, cutting transition time >5.5 seconds, and corneas with donor age >65 years were significantly more likely to have greater than 5% ECD loss after precutting (odds ratio, 6.42, 1.66, and 1.62; 95% confidence interval, 1.44-29.43, 1.45-2.72, and 1.66-5.82, respectively). Donor source, death-to-preservation time (range, 0.67-10.88 hours), death-to-precutting time (range, 0-7 days), and graft thickness (range, 43-232 μm) were not statistically significant factors. The ECD loss in the precut tissue prepared by the eye bank was very low. The risk factors identified provide better understanding of how to improve the quality and safety profiles when preparing graft tissue for Descemet stripping automated endothelial keratoplasty.

  12. AAV-expressed eCD4-Ig provides durable protection from multiple SHIV challenges

    PubMed Central

    Gardner, Matthew R.; Kattenhorn, Lisa M.; Kondur, Hema R.; von Schaewen, Markus; Dorfman, Tatyana; Chiang, Jessica J.; Haworth, Kevin G.; Decker, Julie M.; Alpert, Michael D.; Bailey, Charles C.; Neale, Ernest S.; Fellinger, Christoph H.; Joshi, Vinita R.; Fuchs, Sebastian P.; Martinez-Navio, Jose M.; Quinlan, Brian D.; Yao, Annie Y.; Mouquet, Hugo; Gorman, Jason; Zhang, Baoshan; Poignard, Pascal; Nussenzweig, Michel C.; Burton, Dennis R.; Kwong, Peter D.; Piatak, Michael; Lifson, Jeffrey D.; Gao, Guangping; Desrosiers, Ronald C.; Evans, David T.; Hahn, Beatrice H.; Ploss, Alexander; Cannon, Paula M.; Seaman, Michael S.; Farzan, Michael

    2015-01-01

    Long-term in vivo expression of a broad and potent entry inhibitor could circumvent the need for a conventional vaccine for HIV-1. Adeno-associated virus (AAV) vectors can stably express HIV-1 broadly neutralizing antibodies (bNAbs)1,2. However even the best bNAbs neutralize 10–50% of HIV-1 isolates inefficiently (IC80 > 5 μg/ml), suggesting that high concentrations of these antibodies would be necessary to achieve general protection3–6. Here we show that eCD4-Ig, a fusion of CD4-Ig with a small CCR5-mimetic sulfopeptide, binds avidly and cooperatively to the HIV-1 envelope glycoprotein (Env) and is more potent than the best bNAbs (geometric mean IC50 < 0.05 μg/ml). Because eCD4-Ig binds only conserved regions of Env, it is also much broader than any bNAb. For example, eCD4-Ig efficiently neutralized 100% of a diverse panel of neutralization-resistant HIV-1, HIV-2, and SIV isolates, including a comprehensive set of isolates resistant to the CD4-binding site bNAbs VRC01, NIH45-46, and 3BNC117. Rhesus macaques inoculated with an AAV vector stably expressed 17 to 77 μg/ml of fully functional rhesus eCD4-Ig for 40 weeks, and these macaques were protected from multiple infectious challenges with SHIV-AD8. Rhesus eCD4-Ig was also markedly less immunogenic than rhesus forms of four well characterized bNAbs. Our data suggest that AAV-delivered eCD4-Ig can function like an effective HIV-1 vaccine. PMID:25707797

  13. Thyrotropin Receptor Epitope and Human Leukocyte Antigen in Graves’ Disease

    PubMed Central

    Inaba, Hidefumi; De Groot, Leslie J.; Akamizu, Takashi

    2016-01-01

    Graves’ disease (GD) is an organ-specific autoimmune disease, and thyrotropin (TSH) receptor (TSHR) is a major autoantigen in this condition. Since the extracellular domain of human TSHR (TSHR-ECD) is shed into the circulation, TSHR-ECD is a preferentially immunogenic portion of TSHR. Both genetic factors and environmental factors contribute to development of GD. Inheritance of human leukocyte antigen (HLA) genes, especially HLA-DR3, is associated with GD. TSHR-ECD protein is endocytosed into antigen-presenting cells (APCs), and processed to TSHR-ECD peptides. These peptide epitopes bind to HLA-class II molecules, and subsequently the complex of HLA-class II and TSHR-ECD epitope is presented to CD4+ T cells. The activated CD4+ T cells secrete cytokines/chemokines that stimulate B-cells to produce TSAb, and in turn hyperthyroidism occurs. Numerous studies have been done to identify T- and B-cell epitopes in TSHR-ECD, including (1) in silico, (2) in vitro, (3) in vivo, and (4) clinical experiments. Murine models of GD and HLA-transgenic mice have played a pivotal role in elucidating the immunological mechanisms. To date, linear or conformational epitopes of TSHR-ECD, as well as the molecular structure of the epitope-binding groove in HLA-DR, were reported to be related to the pathogenesis in GD. Dysfunction of central tolerance in the thymus, or in peripheral tolerance, such as regulatory T cells, could allow development of GD. Novel treatments using TSHR antagonists or mutated TSHR peptides have been reported to be effective. We review and update the role of immunogenic TSHR epitopes and HLA in GD, and offer perspectives on TSHR epitope specific treatments. PMID:27602020

  14. Early Childhood Diarrhea Predicts Cognitive Delays in Later Childhood Independently of Malnutrition.

    PubMed

    Pinkerton, Relana; Oriá, Reinaldo B; Lima, Aldo A M; Rogawski, Elizabeth T; Oriá, Mônica O B; Patrick, Peter D; Moore, Sean R; Wiseman, Benjamin L; Niehaus, Mark D; Guerrant, Richard L

    2016-11-02

    Understanding the complex relationship between early childhood infectious diseases, nutritional status, poverty, and cognitive development is significantly hindered by the lack of studies that adequately address confounding between these variables. This study assesses the independent contributions of early childhood diarrhea (ECD) and malnutrition on cognitive impairment in later childhood. A cohort of 131 children from a shantytown community in northeast Brazil was monitored from birth to 24 months for diarrhea and anthropometric status. Cognitive assessments including Test of Nonverbal Intelligence (TONI), coding tasks (WISC-III), and verbal fluency (NEPSY) were completed when children were an average of 8.4 years of age (range = 5.6-12.7 years). Multivariate analysis of variance models were used to assess the individual as well as combined effects of ECD and stunting on later childhood cognitive performance. ECD, height for age (HAZ) at 24 months, and weight for age (WAZ) at 24 months were significant univariate predictors of the studies three cognitive outcomes: TONI, coding, and verbal performance (P < 0.05). Multivariate models showed that ECD remained a significant predictor, after adjusting for the effect of 24 months HAZ and WAZ, for both TONI (HAZ, P = 0.029 and WAZ, P = 0.006) and coding (HAZ, P = 0.025 and WAZ, P = 0.036) scores. WAZ and HAZ were also significant predictors after adjusting for ECD. ECD remained a significant predictor of coding (WISC III) after number of household income was considered (P = 0.006). This study provides evidence that ECD and stunting may have independent effects on children's intellectual function well into later childhood. © The American Society of Tropical Medicine and Hygiene.

  15. Outcomes of cataract surgery in eyes with a low corneal endothelial cell density.

    PubMed

    Yamazoe, Katsuya; Yamaguchi, Takefumi; Hotta, Kazuki; Satake, Yoshiyuki; Konomi, Kenji; Den, Seika; Shimazaki, Jun

    2011-12-01

    To evaluate the surgical outcomes of cataract surgery in eyes with a low preoperative corneal endothelial cell density (ECD) and analyze factors affecting the prognosis. Tokyo Dental College, Ichikawa General Hospital, Chiba, Japan. Noncomparative case series. Eyes with a preoperative ECD of less than 1000 cells/mm(2) that had cataract surgery between 2006 and 2010 were identified. Standard phacoemulsification with intraocular lenses was performed using the soft-shell technique. The rate of endothelial cell loss, incidence of bullous keratopathy, and risk factors were retrospectively assessed. Sixty-one eyes (53 patients) with a low preoperative ECD were identified. Preoperative diagnoses or factors regarded as causing endothelial cell loss included Fuchs dystrophy (20 eyes), laser iridotomy (16 eyes), keratoplasty (10 eyes), traumatic injury (3 eyes), trabeculectomy (3 eyes), corneal endotheliitis (2 eyes), and other (7 eyes). The corrected distance visual acuity improved from 0.59 ± 0.49 logMAR preoperatively to 0.32 ± 0.48 logMAR postoperatively (P<.001). The mean ECD was 693 ± 172 cells/mm(2) and 611 ± 203 cells/mm(2), respectively (P=.001). The mean rate of endothelial cell loss was 11.5% ± 23.4%. Greater ECD loss was associated with a shorter axial length (AL) (<23.0 mm) and diabetes mellitus. Bullous keratopathy developed in 9 eyes (14.8%) and was associated with posterior capsule rupture. The results suggest that modern techniques for cataract surgery provide excellent visual rehabilitation in many patients with a low preoperative ECD. Shorter AL, diabetes mellitus, and posterior capsule rupture were risk factors for greater ECD loss and bullous keratopathy. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. The impact of inter-fraction dose variations on biological equivalent dose (BED): the concept of equivalent constant dose.

    PubMed

    Zavgorodni, S

    2004-12-07

    Inter-fraction dose fluctuations, which appear as a result of setup errors, organ motion and treatment machine output variations, may influence the radiobiological effect of the treatment even when the total delivered physical dose remains constant. The effect of these inter-fraction dose fluctuations on the biological effective dose (BED) has been investigated. Analytical expressions for the BED accounting for the dose fluctuations have been derived. The concept of biological effective constant dose (BECD) has been introduced. The equivalent constant dose (ECD), representing the constant physical dose that provides the same cell survival fraction as the fluctuating dose, has also been introduced. The dose fluctuations with Gaussian as well as exponential probability density functions were investigated. The values of BECD and ECD calculated analytically were compared with those derived from Monte Carlo modelling. The agreement between Monte Carlo modelled and analytical values was excellent (within 1%) for a range of dose standard deviations (0-100% of the dose) and the number of fractions (2 to 37) used in the comparison. The ECDs have also been calculated for conventional radiotherapy fields. The analytical expression for the BECD shows that BECD increases linearly with the variance of the dose. The effect is relatively small, and in the flat regions of the field it results in less than 1% increase of ECD. In the penumbra region of the 6 MV single radiotherapy beam the ECD exceeded the physical dose by up to 35%, when the standard deviation of combined patient setup/organ motion uncertainty was 5 mm. Equivalently, the ECD field was approximately 2 mm wider than the physical dose field. The difference between ECD and the physical dose is greater for normal tissues than for tumours.

  17. Sequestration of latent TGF-β binding protein 1 into CADASIL-related Notch3-ECD deposits.

    PubMed

    Kast, Jessica; Hanecker, Patrizia; Beaufort, Nathalie; Giese, Armin; Joutel, Anne; Dichgans, Martin; Opherk, Christian; Haffner, Christof

    2014-08-13

    Cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL) represents the most common hereditary form of cerebral small vessel disease characterized by early-onset stroke and premature dementia. It is caused by mutations in the transmembrane receptor Notch3, which promote the aggregation and accumulation of the Notch3 extracellular domain (Notch3-ECD) within blood vessel walls. This process is believed to mediate the abnormal recruitment and dysregulation of additional factors including extracellular matrix (ECM) proteins resulting in brain vessel dysfunction. Based on recent evidence indicating a role for the transforming growth factor-β (TGF-β) pathway in sporadic and familial small vessel disease we studied fibronectin, fibrillin-1 and latent TGF-β binding protein 1 (LTBP-1), three ECM constituents involved in the regulation of TGF-β bioavailability, in post-mortem brain tissue from CADASIL patients and control subjects. Fibronectin and fibrillin-1 were found to be enriched in CADASIL vessels without co-localizing with Notch3-ECD deposits, likely as a result of fibrotic processes secondary to aggregate formation. In contrast, LTBP-1 showed both an accumulation and a striking co-localization with Notch3-ECD deposits suggesting specific recruitment into aggregates. We also detected increased levels of the TGF-β prodomain (also known as latency-associated peptide, LAP) indicating dysregulation of the TGF-β pathway in CADASIL development. In vitro analyses revealed a direct interaction between LTBP-1 and Notch3-ECD and demonstrated a specific co-aggregation of LTBP-1 with mutant Notch3. We propose LTBP-1 as a novel component of Notch3-ECD deposits and suggest its involvement in pathological processes triggered by Notch3-ECD aggregation.

  18. Development and implementation of a mobile device-based pediatric electronic decision support tool as part of a national practice standardization project.

    PubMed

    McCulloh, Russell J; Fouquet, Sarah D; Herigon, Joshua; Biondi, Eric A; Kennedy, Brandan; Kerns, Ellen; DePorre, Adrienne; Markham, Jessica L; Chan, Y Raymond; Nelson, Krista; Newland, Jason G

    2018-06-07

    Implementing evidence-based practices requires a multi-faceted approach. Electronic clinical decision support (ECDS) tools may encourage evidence-based practice adoption. However, data regarding the role of mobile ECDS tools in pediatrics is scant. Our objective is to describe the development, distribution, and usage patterns of a smartphone-based ECDS tool within a national practice standardization project. We developed a smartphone-based ECDS tool for use in the American Academy of Pediatrics, Value in Inpatient Pediatrics Network project entitled "Reducing Excessive Variation in the Infant Sepsis Evaluation (REVISE)." The mobile application (app), PedsGuide, was developed using evidence-based recommendations created by an interdisciplinary panel. App workflow and content were aligned with clinical benchmarks; app interface was adjusted after usability heuristic review. Usage patterns were measured using Google Analytics. Overall, 3805 users across the United States downloaded PedsGuide from December 1, 2016, to July 31, 2017, leading to 14 256 use sessions (average 3.75 sessions per user). Users engaged in 60 442 screen views, including 37 424 (61.8%) screen views that displayed content related to the REVISE clinical practice benchmarks, including hospital admission appropriateness (26.8%), length of hospitalization (14.6%), and diagnostic testing recommendations (17.0%). Median user touch depth was 5 [IQR 5]. We observed rapid dissemination and in-depth engagement with PedsGuide, demonstrating feasibility for using smartphone-based ECDS tools within national practice improvement projects. ECDS tools may prove valuable in future national practice standardization initiatives. Work should next focus on developing robust analytics to determine ECDS tools' impact on medical decision making, clinical practice, and health outcomes.

  19. Serum levels of the extracellular domain of the epidermal growth factor receptor in individuals exposed to arsenic in drinking water in Bangladesh.

    PubMed

    Li, Y; Chen, Y; Slavkovic, V; Ahsan, H; Parvez, F; Graziano, J H; Brandt-Rauf, P W

    2007-01-01

    Epidermal growth factor receptor-dependent mechanisms have been implicated in growth signal transduction pathways that contribute to cancer development, including dermal carcinogenesis. Detection of the extracellular domain of the epidermal growth factor receptor (EGFR ECD) in serum has been suggested as a potential biomarker for monitoring this effect in vivo. Arsenic is a known human carcinogen, producing skin and other malignancies in populations exposed through their drinking water. One such exposed population, which we have been studying for a number of years, is in Bangladesh. The purpose of this study was to examine the EGFR ECD as a potential biomarker of arsenic exposure and/or effect in this population. Levels of the EGFR ECD were determined by enzyme-linked immunosorbent assay in the serum samples from 574 individuals with a range of arsenic exposures from drinking water in the Araihazar area of Bangladesh. In multiple regression analysis, serum EGFR ECD was found to be positively associated with three different measures of arsenic exposure (well water arsenic, urinary arsenic and a cumulative arsenic index) at statistically significant levels (p

  20. High-sensitivity brain SPECT system using cadmium telluride (CdTe) semiconductor detector and 4-pixel matched collimator.

    PubMed

    Suzuki, Atsuro; Takeuchi, Wataru; Ishitsu, Takafumi; Tsuchiya, Katsutoshi; Morimoto, Yuichi; Ueno, Yuichiro; Kobashi, Keiji; Kubo, Naoki; Shiga, Tohru; Tamaki, Nagara

    2013-11-07

    For high-sensitivity brain imaging, we have developed a two-head single-photon emission computed tomography (SPECT) system using a CdTe semiconductor detector and 4-pixel matched collimator (4-PMC). The term, '4-PMC' indicates that the collimator hole size is matched to a 2 × 2 array of detector pixels. By contrast, a 1-pixel matched collimator (1-PMC) is defined as a collimator whose hole size is matched to one detector pixel. The performance of the higher-sensitivity 4-PMC was experimentally compared with that of the 1-PMC. The sensitivities of the 1-PMC and 4-PMC were 70 cps/MBq/head and 220 cps/MBq/head, respectively. The SPECT system using the 4-PMC provides superior image resolution in cold and hot rods phantom with the same activity and scan time to that of the 1-PMC. In addition, with half the usual scan time the 4-PMC provides comparable image quality to that of the 1-PMC. Furthermore, (99m)Tc-ECD brain perfusion images of healthy volunteers obtained using the 4-PMC demonstrated acceptable image quality for clinical diagnosis. In conclusion, our CdTe SPECT system equipped with the higher-sensitivity 4-PMC can provide better spatial resolution than the 1-PMC either in half the imaging time with the same administered activity, or alternatively, in the same imaging time with half the activity.

  1. Large-area flexible monolithic ITO/WO3/Nb2O5/NiVOχ/ITO electrochromic devices prepared by using magnetron sputter deposition

    NASA Astrophysics Data System (ADS)

    Tang, Chien-Jen; Ye, Jia-Ming; Yang, Yueh-Ting; He, Ju-Liang

    2016-05-01

    Electrochromic devices (ECDs) have been applied in smart windows to control the transmission of sunlight in green buildings, saving up to 40-50% electricity consumption and ultimately reducing carbon dioxide emissions. However, the high manufacturing costs and difficulty of transportation of conventional massive large area ECDs has limited widespread applications. A unique design replacing the glass substrate commonly used in the ECD windows with inexpensive, light-weight and flexible polymeric substrate materials would accelerate EC adoption allowing them to be supplemented for regular windows without altering window construction. In this study, an ITO/WO3/Nb2O5/NiVOχ/ITO all-solid-state monolithic ECD with an effective area of 24 cm × 18 cm is successfully integrated on a PET substrate by using magnetron sputter deposition. The electrochromic performance and bending durability of the resultant material are also investigated. The experimental results indicate that the ultimate response times for the prepared ECD is 6 s for coloring at an applied voltage of -3 V and 5 s for bleaching at an applied voltage of +3 V, respectively. The optical transmittances for the bleached and colored state at a wavelength of 633 nm are 53% and 11%, respectively. The prepared ECD can sustain over 8000 repeated coloring and bleaching cycles, as well as tolerate a bending radius of curvature of 7.5 cm.

  2. Assessment of the reliability of human corneal endothelial cell-density estimates using a noncontact specular microscope.

    PubMed

    Doughty, M J; Müller, A; Zaman, M L

    2000-03-01

    We sought to determine the variance in endothelial cell density (ECD) estimates for human corneal endothelia. Noncontact specular micrographs were obtained from white subjects without any history of contact lens wear, or major eye disease or surgery; subjects were within four age groups (children, young adults, older adults, senior citizens). The endothelial image was scanned, and the areas from > or =75 cells measured from an overlay by planimetry. The cell-area values were used to calculate the ECD repeatedly so that the intra- and intersubject variation in an average ECD estimate could be made by using different numbers of cells (5, 10, 15, etc.). An average ECD of 3,519 cells/mm2 (range, 2,598-5,312 cells/mm2) was obtained of counts of 75 cells/ endothelium from individuals aged 6-83 years. Average ECD estimates in each age group were 4,124, 3,457, 3,360, and 3,113 cells/mm2, respectively. Analysis of intersubject variance revealed that ECD estimates would be expected to be no better than +/-10% if only 25 cells were measured per endothelium, but approach +/-2% if 75 cells are measured. In assessing the corneal endothelium by noncontact specular microscopy, cell count should be given, and this should be > or =75/ endothelium for an expected variance to be at a level close to that recommended for monitoring age-, stress-, or surgery-related changes.

  3. Development of the focal plane system for the SEparator for CApture Reactions

    NASA Astrophysics Data System (ADS)

    Hood, A. A. D.; Blackmon, J. C.; Cottingham, R.; Deibel, C. M.; Good, E.; Joerres, K.; Laminack, A.; Garrity, A.; Secar Collaboration

    2017-09-01

    The SEparator for CApture Reactions (SECAR) is currently under construction for the National Superconducting Cyclotron Laboratory and future Facility for Rare Isotope Beams. SECAR is designed to conduct sensitive measurements of capture reactions critical to understanding stellar explosions. We have developed a versatile focal plane system that will differentiate reaction recoils from unreacted scattered beam particles in measurements covering a large range of energies and masses. The elements of the focal plane system include two metal-foil, micro-channel plate (MCP) detectors, a variety of diagnostics, and two alternative recoil stopping detectors. The MCP detectors will measure the time-of-flight (and therefore velocity) as well as the position of the recoils. Our primary heavy ion recoil detector is a gas ionization chamber that measures position, total energy and relative energy loss and provides good atomic number discrimination at energies greater than about 0.5 MeV/u. For some cases, this gas counter will be replaced by silicon strip detectors to provide superior energy resolution. We will describe the overall design and report on construction and testing of the detector systems. Supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics, under Awards DE-SC0014384 and DE-FG02-96ER40978.

  4. Fuels for urban transit buses: a cost-effectiveness analysis.

    PubMed

    Cohen, Joshua T; Hammitt, James K; Levy, Jonathan I

    2003-04-15

    Public transit agencies have begun to adopt alternative propulsion technologies to reduce urban transit bus emissions associated with conventional diesel (CD) engines. Among the most popular alternatives are emission controlled diesel buses (ECD), defined here to be buses with continuously regenerating diesel particle filters burning low-sulfur diesel fuel, and buses burning compressed natural gas (CNG). This study uses a series of simplifying assumptions to arrive at first-order estimates for the incremental cost-effectiveness (CE) of ECD and CNG relative to CD. The CE ratio numerator reflects acquisition and operating costs. The denominator reflects health losses (mortality and morbidity) due to primary particulate matter (PM), secondary PM, and ozone exposure, measured as quality adjusted life years (QALYs). We find that CNG provides larger health benefits than does ECD (nine vs six QALYs annually per 1000 buses) but that ECD is more cost-effective than CNG (dollar 270 000 per QALY for ECD vs dollar 1.7 million to dollar 2.4 million for CNG). These estimates are subject to much uncertainty. We identify assumptions that contribute most to this uncertainty and propose potential research directions to refine our estimates.

  5. Development of real-time thermal neutron monitor using boron-loaded plastic scintillator with optical fiber for boron neutron capture therapy.

    PubMed

    Ishikawa, M; Ono, K; Sakurai, Y; Unesaki, H; Uritani, A; Bengua, G; Kobayashi, T; Tanaka, K; Kosako, T

    2004-11-01

    A new thermal neutron monitor for boron neutron capture therapy was developed in this study. We called this monitor equipped boron-loaded plastic scintillator that uses optical fiber for signal transmission as an [scintillator with optical fiber] SOF detector. A water phantom experiment was performed to verify how the SOF detector compared with conventional method of measuring thermal neutron fluence. Measurements with a single SOF detector yielded indistinguishable signals for thermal neutrons and gamma rays. To account for the gamma ray contribution in the signal recorded by the SOF detector, a paired SOF detector system was employed. This was composed of an SOF detector with boron-loaded scintillator and an SOF detector with a boron-free scintillator. The difference between the recorded counts of these paired SOF detectors was used as the measure of the gamma ray contribution in the measured neutron fluence. The paired SOF detectors were ascertained to be effective in measuring thermal neutron flux in the range above 10(6)(n/cm(2)/s). Clinical trials using paired SOF to measure thermal neutron flux during therapy confirmed that paired SOF detectors were effective as a real-time thermal neutron flux monitor.

  6. Neutron Resonance Spin Determination Using Multi-Segmented Detector DANCE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baramsai, B.; Mitchell, G. E.; Chyzh, A.

    2011-06-01

    A sensitive method to determine the spin of neutron resonances is introduced based on the statistical pattern recognition technique. The new method was used to assign the spins of s-wave resonances in {sup 155}Gd. The experimental neutron capture data for these nuclei were measured with the DANCE (Detector for Advanced Neutron Capture Experiment) calorimeter at the Los Alamos Neutron Science Center. The highly segmented calorimeter provided detailed multiplicity distributions of the capture {gamma}-rays. Using this information, the spins of the neutron capture resonances were determined. With these new spin assignments, level spacings are determined separately for s-wave resonances with J{supmore » {pi}} = 1{sup -} and 2{sup -}.« less

  7. The Oceanic Cycle and Global Atmospheric Budget of Carbonyl Sulfide.

    NASA Astrophysics Data System (ADS)

    Weiss, Peter Scott

    1995-01-01

    A significant portion of stratospheric air chemistry is influenced by the existence of carbonyl sulfide (COS). This ubiquitous sulfur gas represents a major source of sulfur to the stratosphere where it is converted to sulfuric acid aerosol particles. Stratospheric aerosols are climatically important because they scatter incoming solar radiation back to space and are able to increase the catalytic destruction of ozone through gas phase reactions on particle surfaces. COS is primarily formed at the surface of the earth, in both marine and terrestrial environments, and is strongly linked to natural biological processes. However, many gaps in the understanding of the global COS cycle still exist, which has led to a global atmospheric budget that is out of balance by a factor of two or more, and a lack of understanding of how human activity has affected the cycling of this gas. The goal of this study was to focus on COS in the marine environment by investigating production/destruction mechanisms and recalculating the ocean-atmosphere flux. Analytical work was carried out using the electron capture sulfur detector (ECD-S) for gas chromatography. This system was optimized for COS so that air and seawater-equilibrated air samples could be directly injected without preconcentration. This research was carried out on two cruises aboard the NOAA ship Surveyor during long meridional transects between 55^circN and 70 ^circS along 140^circ W in the Pacific Ocean. The major findings of these research activities are: (1) Photoproduction of COS is at a maximum between 313 and 336 nm in natural sunlit waters. Tropical water surface and column production rates are 68 pM/day and 360 nmol/m^2/day, respectively. Antarctic surface and column production rates are 101 pM/day and 620 nmol/m^2/day, respectively. (2) Wide regions of the open ocean were found to be undersaturated with respect to atmospheric equilibrium of COS. The global open ocean sea-air flux of COS was found to be -0.032 (-0.010 to -0.054) which represents a very weak sink of atmospheric COS. (3) Daily COS concentration losses in surface waters were used to determine seawater lifetimes, which agreed to hydrolysis lifetimes to within 15%. (4) Atmospheric COS mixing ratios displayed <5% interhemispheric ratio. However, seasonal variation in the northern hemisphere may have been as high as 10%. (5) A simple steady-state model was developed to predict seasonal cycles of atmospheric COS.

  8. Directional Antineutrino Detection

    NASA Astrophysics Data System (ADS)

    Safdi, Benjamin R.; Suerfu, Burkhant

    2015-02-01

    We propose the first event-by-event directional antineutrino detector using inverse beta decay (IBD) interactions on hydrogen, with potential applications including monitoring for nuclear nonproliferation, spatially mapping geoneutrinos, characterizing the diffuse supernova neutrino background and searching for new physics in the neutrino sector. The detector consists of adjacent and separated target and capture scintillator planes. IBD events take place in the target layers, which are thin enough to allow the neutrons to escape without scattering elastically. The neutrons are detected in the thicker boron-loaded capture layers. The location of the IBD event and the momentum of the positron are determined by tracking the positron's trajectory through the detector. Our design is a straightforward modification of existing antineutrino detectors; a prototype could be built with existing technology.

  9. Capture-gated Spectroscopic Measurements of Monoenergetic Neutrons with a Composite Scintillation Detector

    NASA Astrophysics Data System (ADS)

    Nattress, Jason; Mayer, M.; Foster, A.; Meddeb, A. Barhoumi; Trivelpiece, C.; Ounaies, Z.; Jovanovic, I.

    2016-04-01

    We report on the measurements of monoenergetic neutrons from DD and DT fusion reactions by use of the capture gating method in a heterogeneous plastic-glass composite scintillation detector. The cylindrical detector is 5.08 cm in diameter and 5.05 cm in height and was fabricated using 1-mm diameter Li-doped glass rods (GS20) and scintillating polyvinyl toluene (EJ-290). Different scintillation decay constants are used to identify energy depositions in two materials constituting the composite scintillator. Geant4 simulations of the neutron thermalization and capture process were conducted, finding a mean capture time of approximately 2.6 μs for both DD and DT neutrons. A capture gating time acceptance window based on simulation results was used to identify the neutron thermalization pulses. The total scintillation light yield produced in neutron thermalization was measured and found to show consistency on event-by-event basis despite the variety of neutron thermalization histories prior to capture. The ratio of light yields from thermalization of 14.1 MeV and 2.45 MeV neutrons in the EJ-290 scintillator was determined to be 14.6, and the light output from 2.45 MeV neutrons was also correlated to its electron equivalent, obtaining a value of 0.58±0.05 MeVee.

  10. GC and GC-MS determination of fluoroacetic acid and phenoxy acid herbicides via triphasal extractive pentafluorobenzylation using a polymer-bound phase-transfer catalyst.

    PubMed

    Miki, A; Tsuchihashi, H; Yamashita, M

    1998-01-01

    A simple and sensitive gas chromatography and gas chromatography-mass spectrometry (GC-MS) procedure has been developed for fluoroacetic acid (FA) and phenoxy acid herbicides (PAHs) via triphasal extractive pentafluorobenzylation. The triphasal system consisted of an aqueous sample, the extraction solvent toluene containing pentafluorobenzyl bromide as the derivatization reagent, and polymer-bound tri-n-butyl-methylphosphonium bromide as a phase-transfer catalyst, FA spiked in beverages, such as orange juice and milk, was extracted as its pentafluorobenzyl (PFB) derivative under moderate conditions (i.e., at a pH value of 6.5 at 60 degrees C). The detection limits were 0.10-0.20 microgram/mL by GC with electron-capture detection (GC-ECD), and 0.42-0.50 microgram/mL by full-scan GC-MS. PAHs were also detectable in the same manner within the detection limits of 0.05-0.10 microgram/mL by GC-ECD and 0.13-0.25 microgram/mL by full-scan GC-MS. Urine and serum which both contained 2,4-dichlorophenoxyacetic acid could also be analyzed by GC-MS after the triphasal pentafluorobenzylation. The detection limit was 0.20 microgram/mL in the full-scan mode and 10 ng/mL in the selected ion monitoring mode both for the urine and serum.

  11. DECHLORINATION OF TRICHLOROETHYLENE USING ELECTROCHEMICAL METHODS

    EPA Science Inventory

    Electrochemical degradation (ECD) is used to decontaminate organic and inorganic contaminants through oxidative or reductive processes. The ECD of Trichloroethylene (TCE) dechlorinates TCE through electric reduction. TCE dechlorination presented in the literature utilized electro...

  12. Neonatal Morbidity and Mortality After Elective Cesarean Delivery

    PubMed Central

    Signore, Caroline; Klebanoff, Mark

    2008-01-01

    As overall cesarean delivery rates have continued to rise, there has been growing interest in the rates of elective cesarean delivery (ECD), and its relative benefits and harms for the mother and neonate. This article explores the effects of elective cesarean delivery at term on neonatal morbidity and mortality. Available data are subject to a number of limitations, and do not provide conclusive evidence regarding the safety of planned elective cesarean versus planned vaginal delivery. Nevertheless, some data suggest an association between ECD and increased neonatal respiratory morbidity and lacerations, and possibly decreased central and peripheral nervous system injury. Potentially increased risks of neonatal mortality with ECD at term may be counterbalanced by risks of fetal demise in ongoing pregnancies. Patients and physicians considering ECD should carefully review competing risks and benefits; further research is needed to inform these discussions. PMID:18456074

  13. Does endothelial cell density correlate with corneal diameter in a group of young adults?

    PubMed

    Giasson, Claude J; Gosselin, Lucie; Masella, Aviva; Forcier, Pierre

    2008-07-01

    In children, but not in the elderly, an association exists between corneal diameter and endothelial cell density (ECD). We tested whether such an association also held true in young adults. The eyes of 35 healthy subjects (mean age, 23.1 +/- 3.1 years) were photographed by using a video camera and a noncontact endothelial microscope. Both sets of images were analyzed with image software and the contour method to measure corneal diameter, ECD, and endothelial coefficients. Axial lengths, refractive errors, and corneal curvatures were measured by using an A-scan ultrasonic biometer and kerato-refractometer. Measurements, averaged for the right and left eyes, were analyzed depending on (1) use of contact lenses, (2) ametropia, and on whether (3) axial length or (4) corneal diameter was above or below group means. Differences were tested for statistical significance with independent t tests and association with the Pearson correlation coefficient. ECD, corneal diameter, and spherical equivalent refraction were 3022 +/- 262 cells/mm2, 12.0 +/- 0.5 mm, and -3.1 +/- 2.5 D, respectively. The only significant differences between wearers and nonwearers of contact lenses were the spherical refractive equivalent and axial length. There was no correlation between ECD and corneal diameter or axial length. As opposed to previously reported results in children, but as found in the elderly, there is no correlation between ECD and corneal diameter in young adults. Therefore, corneal size cannot be considered a determinant of ECD in young adults.

  14. Dual Kidney Transplantation: Is It Worth It?

    PubMed

    Snanoudj, Renaud; Timsit, Marc-Olivier; Rabant, Marion; Tinel, Claire; Lazareth, Hélène; Lamhaut, Lionel; Martinez, Frank; Legendre, Christophe

    2017-03-01

    Use of expanded criteria donor (ECD) kidneys, which are associated with a reduced graft survival rate, has become widely adopted in elderly recipients in an old-to-old allocation system. However, the results are frequently unsatisfactory, and a high proportion of these ECD kidneys are discarded. Dual kidney transplantation (DKT) is an underused way to expand the pool of ECD kidneys and to rapidly transplant elderly patients with satisfactory results because of the transplantation of double the nephronic mass. In this overview, we summarize the results of the main studies on DKT. DKT suffers from a prejudice of heaviness and is considered to be useless by transplant centers that do not perform it. The literature is often biased by the heterogeneity of the criteria leading to a DKT and the common refusal of kidneys that are judged too marginal. In fact, we show that when strictly allocated according to reliable clinical or histological scores, dual and single ECD transplantations yield similar results in terms of patient and graft survival rates despite significant differences in donors' characteristics. DKTs are not associated with a higher proportion of surgical complications, except in some studies showing thrombosis of 1 of the 2 grafts. The benefits of dual transplantation are particularly evident for kidneys coming from most ECDs. There is still a need for more studies to find the best allocation criteria that would permit transplantation to the highest number of patients with similar outcomes in recipients of single and dual ECD kidneys.

  15. Structural and Genetic Analyses of the Mycobacterium tuberculosis Protein Kinase B Sensor Domain Identify a Potential Ligand-binding Site.

    PubMed

    Prigozhin, Daniil M; Papavinasasundaram, Kadamba G; Baer, Christina E; Murphy, Kenan C; Moskaleva, Alisa; Chen, Tony Y; Alber, Tom; Sassetti, Christopher M

    2016-10-28

    Monitoring the environment with serine/threonine protein kinases is critical for growth and survival of Mycobacterium tuberculosis, a devastating human pathogen. Protein kinase B (PknB) is a transmembrane serine/threonine protein kinase that acts as an essential regulator of mycobacterial growth and division. The PknB extracellular domain (ECD) consists of four repeats homologous to penicillin-binding protein and serine/threonine kinase associated (PASTA) domains, and binds fragments of peptidoglycan. These properties suggest that PknB activity is modulated by ECD binding to peptidoglycan substructures, however, the molecular mechanisms underpinning PknB regulation remain unclear. In this study, we report structural and genetic characterization of the PknB ECD. We determined the crystal structures of overlapping ECD fragments at near atomic resolution, built a model of the full ECD, and discovered a region on the C-terminal PASTA domain that has the properties of a ligand-binding site. Hydrophobic interaction between this surface and a bound molecule of citrate was observed in a crystal structure. Our genetic analyses in M. tuberculosis showed that nonfunctional alleles were produced either by deletion of any of single PASTA domain or by mutation of individual conserved residues lining the putative ligand-binding surface of the C-terminal PASTA repeat. These results define two distinct structural features necessary for PknB signal transduction, a fully extended ECD and a conserved, membrane-distal putative ligand-binding site. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.

  16. Feasibility study of a large-scale tuned mass damper with eddy current damping mechanism

    NASA Astrophysics Data System (ADS)

    Wang, Zhihao; Chen, Zhengqing; Wang, Jianhui

    2012-09-01

    Tuned mass dampers (TMDs) have been widely used in recent years to mitigate structural vibration. However, the damping mechanisms employed in the TMDs are mostly based on viscous dampers, which have several well-known disadvantages, such as oil leakage and difficult adjustment of damping ratio for an operating TMD. Alternatively, eddy current damping (ECD) that does not require any contact with the main structure is a potential solution. This paper discusses the design, analysis, manufacture and testing of a large-scale horizontal TMD based on ECD. First, the theoretical model of ECD is formulated, then one large-scale horizontal TMD using ECD is constructed, and finally performance tests of the TMD are conducted. The test results show that the proposed TMD has a very low intrinsic damping ratio, while the damping ratio due to ECD is the dominant damping source, which can be as large as 15% in a proper configuration. In addition, the damping ratios estimated with the theoretical model are roughly consistent with those identified from the test results, and the source of this error is investigated. Moreover, it is demonstrated that the damping ratio in the proposed TMD can be easily adjusted by varying the air gap between permanent magnets and conductive plates. In view of practical applications, possible improvements and feasibility considerations for the proposed TMD are then discussed. It is confirmed that the proposed TMD with ECD is reliable and feasible for use in structural vibration control.

  17. γ{\\hbox-}Flash suppression using a gated photomultiplier assembled with an LaBr3(Ce) detector to measure fast neutron capture reactions

    NASA Astrophysics Data System (ADS)

    Hara, K. Y.; Harada, H.; Toh, Y.; Hori, J.

    2013-09-01

    A gated photomultiplier tube (PMT) assembled with an LaBr3(Ce) detector was applied toward the prompt γ{hbox-}ray measurement of fast neutron capture reactions. Time-of-flight measurements of the neutron capture reactions of Cl and Al were performed using the 46-MeV electron linear accelerator at the Kyoto University Research Reactor Institute (KURRI) as a pulsed neutron source. The photomultiplier gating technique effectively suppressed the saturation of the PMT output and extended the energy region of the TOF measurement.

  18. Multiwalled carbon nanotubes coated fibers for solid-phase microextraction of polybrominated diphenyl ethers in water and milk samples before gas chromatography with electron-capture detection.

    PubMed

    Wang, Jun-Xia; Jiang, Dong-Qing; Gu, Zhi-Yuan; Yan, Xiu-Ping

    2006-12-22

    Determination of polybrominated diphenyl ethers (PBDEs) in environmental samples has raised great concerns due to the widespread use of PBDEs and their potential risk to humans. Solid-phase microextraction (SPME) is a fast, simple, cost-effective, and green sample preparation technique and is widely used for environmental analysis, but reports on the application of SPME for determination of PBDEs are very limited, and only a few publications dealing with commercial SPME fibers are available for extraction of PBDEs. Herein, we report a novel SPME method using multiwalled carbon nanotubes (MWCNTs) as the SPME fiber coating for gas chromatography with electron-capture detection (GC-ECD) of PBDEs in environmental samples. The MWCNTs coating gave much higher enhancement factors (616-1756) than poly (5% dibenzene-95% dimethylsiloxane) coating (139-384) and activated carbon coating (193-423). Thirty-minute extraction of 10 mL of sample solution using the MWCNTs coated fiber for GC-ECD determination yielded the limits of detection of 3.6-8.6 ng L(-1) and exhibited good linearity of the calibration functions (r(2)>0.995). The precision (RSD%, n=4) for peak area and retention time at the 500 ng L(-1) level was 6.9-8.8% and 0.6-0.9%, respectively. The developed method was successfully applied for the analysis of real samples including local river water, wastewater, and milk samples. The recovery of the PBDEs at 500 ng L(-1) spiked in these samples ranged from 90 to 119%. No PBDEs were detected in the river water and skimmed milk samples, whereas in the wastewater sample, 134-215 ng L(-1) of PBDEs were found. The PBDEs were detected in all whole fat milk samples, ranging from 13 to 484 ng L(-1). In a semiskimmed milk sample, only BDE-47 was found at 21 ng L(-1).

  19. Asymmetric resonance response analysis of a thermally excited silicon microcantilever for mass-sensitive nanoparticle detection

    NASA Astrophysics Data System (ADS)

    Bertke, Maik; Hamdana, Gerry; Wu, Wenze; Wasisto, Hutomo Suryo; Peiner, Erwin

    2017-06-01

    The asymmetric resonance responses of a thermally actuated silicon microcantilever of a portable, cantilever-based nanoparticle detector (Cantor) is analysed. For airborne nanoparticle concentration measurements, the cantilever is excited in its first in-plane bending mode by an integrated p-type heating actuator. The mass-sensitive nanoparticle (NP) detection is based on the resonance frequency (f0) shifting due to the deposition of NPs. A homemade phase-locked loop (PLL) circuit is developed for tracking of f0. For deflection sensing the cantilever contains an integrated piezo-resistive Wheatstone bridge (WB). A new fitting function based on the Fano resonance is proposed for analysing the asymmetric resonance curves including a method for calculating the quality factor Q from the fitting parameters. To obtain a better understanding, we introduce an electrical equivalent circuit diagram (ECD) comprising a series resonant circuit (SRC) for the cantilever resonator and voltage sources for the parasitics, which enables us to simulate the asymmetric resonance response and discuss the possible causes. Furthermore, we compare the frequency response of the on-chip thermal excitation with an external excitation using an in-plane piezo actuator revealing parasitic heating of the WB as the origin of the asymmetry. Moreover, we are able to model the phase component of the sensor output using the ECD. Knowing and understanding the phase response is crucial to the design of the PLL and thus the next generation of Cantor.

  20. Monitoring system for a liquid-cooled nuclear fission reactor

    DOEpatents

    DeVolpi, Alexander

    1987-01-01

    A monitoring system for detecting changes in the liquid levels in various regions of a water-cooled nuclear power reactor, viz., in the downcomer, in the core, in the inlet and outlet plenums, at the head, and elsewhere; and also for detecting changes in the density of the liquid in these regions. A plurality of gamma radiation detectors are used, arranged vertically along the outside of the reactor vessel, and collimator means for each detector limits the gamma-radiation it receives as emitting from only isolated regions of the vessel. Excess neutrons produced by the fission reaction will be captured by the water coolant, by the steel reactor walls, or by the fuel or control structures in the vessel. Neutron capture by steel generates gamma radiation having an energy level of the order of 5-12 MeV, whereas neutron capture by water provides an energy level of approximately 2.2 MeV, and neutron capture by the fission fuel or its cladding provides an energy level of 1 MeV or less. The intensity of neutron capture thus changes significantly at any water-metal interface. Comparative analysis of adjacent gamma detectors senses changes from the normal condition with liquid coolant present to advise of changes in the presence and/or density of the coolant at these specific regions. The gamma detectors can also sense fission-product gas accumulation at the reactor head to advise of a failure of fuel-pin cladding.

  1. New High-Frequency Measurements of CH4, N2O and SF6 from a High-Altitude Station in the Eastern Himalayas of India and Derived Emissions Estimates

    NASA Astrophysics Data System (ADS)

    Ganesan, A. L.; Chatterjee, A.; Salameh, P.; Harth, C. M.; Rigby, M.; Manning, A. J.; Hall, B. D.; Ghosh, S. K.; Muhle, J.; Meredith, L. K.; Mandal, T. K.; Weiss, R. F.; Prinn, R. G.

    2012-12-01

    We present new in situ measurements from a station in Darjeeling, India (27.03°N, 88.26°E, 2200 m above sea level). These measurements comprise the first high-frequency dataset of methane (CH4), nitrous oxide (N2O) and sulfur hexafluoride (SF6) collected in India. Measurements are made with a gas chromatographic system, using a flame ionization detector (GC-FID) for CH4 and an electron capture detector (GC-ECD) for N2O and SF6. Measurements have been linked to calibration scales used in the Advanced Global Atmospheric Gases Experiment (AGAGE, Tohoku University for CH4 and Scripps institution of Oceanography 1998 and 2005, for N2O and SF6, respectively). Preliminary results show a significant diurnal cycle for CH4, consistent with upslope flows bringing local emissions from the town and valley to the site during the day and downslope flows bringing cleaner air at night. This nighttime decrease in mixing ratio could be attributed to a variety of factors, including reduced local emissions or sampling of cleaner, free tropospheric air from aloft. Underlying this local signal is a much larger regional influence, which is driven by the large-scale meteorology that governs which upwind regions contribute to the measured mole fractions at the site. We also investigate local influences on N2O and SF6, which are much smaller than CH4 or negligible, because of their comparatively weaker nearby sources. We present emissions estimates for India using the high-resolution UK Met Office Lagrangian particle dispersion model, the Numerical Atmospheric dispersion Modeling Environment (NAME). Air histories generated using NAME reveal that the site regularly intercepts air from important rice-growing and biomass burning regions of Northern India. This unique dataset allows further constraints to be placed on "top-down" estimates of emissions from these CH4 sources. Further constraints will also be possible for regional agricultural sources of N2O and South-Asian SF6, both of which are under-sampled and poorly understood at present.

  2. Relationships between organic nitrates and surface ozone destruction during Polar Sunrise Experiment 1992

    NASA Astrophysics Data System (ADS)

    Muthuramu, K.; Shepson, P. B.; Bottenheim, J. W.; Jobson, B. T.; Niki, H.; Anlauf, K. G.

    1994-12-01

    Concurrent measurements of total reactive odd nitrogen species (i.e., NOy) and its major components, including organic nitrates, were carried out during 1992 Polar Sunrise Experiment (PSE92) at Alert, Northwest Territories, Canada, to investigate the episodic depletion of surface level ozone following polar sunrise. A series of C3-C7 alkyl nitrates formed from the atmospheric oxidation of hydrocarbons was measured daily during the 13-week study period (January 22 to April 22). In addition, a large number of gas chromatography/electron capture detector (GC/ECD) peaks with retention times greater than those of the hexyl nitrates were also identified as species containing -ONO2 group(s), using a nitrogen specific detector. The total concentrations of these organic nitrates ranged from 34 to 128 parts per trillion by volume and the distribution in the dark period was found to be similar to that found for rural lower-latitude air masses. In contrast to observations made at lower latitudes where alkyl nitrates make a relatively small contribution to NOy, the organic nitrates at Alert were found to contribute between 7 and 20% of the total odd nitrogen species. After polar sunrise the total concentrations of these organic nitrates decreased steadily, due primarily to the consumption of larger (>C4) alkyl nitrates. The C3 alkyl nitrate concentrations showed little variation during this study. During ozone depletion episodes in April there was a positive correlation between the concentration of the larger organic nitrates and ozone. Most surprisingly, the ratio of concentrations of isomeric alkyl nitrates with carbon numbers ≥5, and in particular those involving the C5 isomers, was found to show substantial variations coinciding with the O3 depletion events. This change in the isomeric alkyl nitrate ratios implies a substantial chemical processing of the air masses exhibiting ozone depletion. The possible mechanisms, which must involve consumption of the organic nitrates by either OH radicals or Cl atoms, are discussed in the context of the chemical and meteorological observations conducted at Alert during these ozone depletion events.

  3. The Influence of Maternal and Household Resources, and Parental Psychosocial Child Stimulation on Early Childhood Development: A Cross-Sectional Study of Children 36–59 Months in Honduras

    PubMed Central

    Urke, Helga Bjørnøy; Contreras, Mariela; Matanda, Dennis Juma

    2018-01-01

    Optimal early childhood development (ECD) is currently jeopardized for more than 250 million children under five in low- and middle-income countries. The Sustainable Development Goals has called for a renewed emphasis on children’s wellbeing, encompassing a holistic approach that ensures nurturing care to facilitate optimal child development. In vulnerable contexts, the extent of a family’s available resources can influence a child’s potential of reaching its optimal development. Few studies have examined these relationships in low- and middle-income countries using nationally representative samples. The present paper explored the relationships between maternal and paternal psychosocial stimulation of the child as well as maternal and household resources and ECD among 2729 children 36–59 months old in Honduras. Data from the Demographic and Health Surveys conducted in 2011–2012 was used. Adjusted logistic regression analyses showed that maternal psychosocial stimulation was positively and significantly associated with ECD in the full, rural, and lowest wealth quintile samples. These findings underscore the importance of maternal engagement in facilitating ECD but also highlight the role of context when designing tailored interventions to improve ECD. PMID:29735895

  4. Notch as a Diagnostic Marker and Therapeutic Target in Human Breast Cancer

    DTIC Science & Technology

    2008-05-01

    JAG1. The soluble JAG1-ECD-FLAG was expressed in Chinese Hamster ovary K1 (CHO-K1) cells and then CHO clones were screened for their ability to... medium was collected from CHO-K1- hJAG1-ECD-Flag (clone14) grown in culture. The purification strategy to obtain hJAG1-ECD-Flag is as follows: 1) pre...expressed in Chinese hampster ovary K1 (CHO-K1) cells and then CHO clones were screened for their ability to express high levels of secreted JAG1-Flag

  5. Expanded criteria donor and donation after circulatory death renal allografts in the West of Scotland: Their place in the kidney allocation process.

    PubMed

    Hesse, Kerrick; Aitken, Emma; Clancy, Marc; Vesey, Alex

    2016-06-01

    Due to the rising disparity between demand and availability, organs from expanded criteria donors (ECD) and donors after determination of circulatory death (DCD) are increasingly used. The purpose of this study was to report outcomes in recipients of ECD and DCD renal allografts from a single centre. A retrospective analysis from a single centre for all renal transplants performed between 2001 and 2010 inclusive was undertaken. SCD (standard criteria donor) and ECD organs were compared, as were DCD and DBD (donation after determination of brain stem death) organs. Baseline data and predefined standard transplant outcomes were collected and compared using appropriate statistical tests. P < 0.05 was defined as significant. 729 renal transplants were performed. Comparing ECD to SCD organs, there was a significant difference in graft survival between groups (logrank for trend, p = 0.032) with ECD organs doing worse than SCD organs. Short-term outcomes showed a similar disparity with a higher 1-year post-transplant creatinine and delayed graft function (DGF) rate in ECD grafts. Nevertheless, outcomes were still clinically acceptable. When comparing DCD to DBD organs, no such differences were apparent, with DCD organs appearing to perform at least as well as DBD organs. In our cohort, unlike some previous studies, DGF rates were similar in both DCD and DBD groups. Although ECD organs perform less well than SCD organs, outcomes are still acceptable and our results support their continuing use. When considering DCD organs, our data support the view that they should no longer be necessarily regarded as marginal grafts. Our low DGF rates are perhaps explained by local factors contributing to a short CIT. Copyright © 2014 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  6. Predictors of liver donation without kidney recovery in a cohort of expanded criteria donors: identifying opportunities to improve expanded criteria donor kidney utilization.

    PubMed

    White, S L; Leichtman, A B; O'Connor, K; Lipkowitz, G; Pietroski, R; Stoff, J S; Luskin, R S; Belcher, J; Meyer, K; Merion, R M; Port, F K; Delmonico, F L

    2012-09-01

    To maximize deceased donation, it is necessary to facilitate organ recovery from expanded criteria donors (ECDs). Utilization of donors meeting the kidney definition for ECDs increases access to kidney transplantation and reduces waiting times; however, ECDs often do not proceed to kidney recovery. Based on a prospective study of three Organ Procurement Organizations in the United States, we describe the characteristics of donors meeting the Organ Procurement and Transplant Network (OPTN) ECD kidney definition (donor age 60+ or donor age 50-60 years with two of the following: final serum creatinine > 1.5 mg/dL, history of hypertension, or death from cerebral vascular accident) who donated a liver without kidney recovery. ECDs with organs recovered between February 2003 and September 2005 by New England Organ Bank, Gift of Life Michigan, and LifeChoice Donor Services were studied (n = 324). All donors were declared dead by neurological criteria. Data on a wide range of donor characteristics were collected, including donor demographics, medical history, cause of death, donor status during hospitalization, serological status, and donor kidney quality. Logistic regression models were used to identify donor characteristics predictive of liver-alone donation. Seventy-four of the 324 donors fulfilling the ECD definition for kidneys donated a liver alone (23%). History of diabetes, final serum creatinine > 1.5 mg/dL, age 70+, and presence of proteinuria were associated with liver-alone donation in univariate models. On multivariate analysis, only final serum creatinine > 1.5 mg/dL and age 70+ were independently predictive of liver donation alone. Older age and elevated serum creatinine may be perceived as stronger contraindications to kidney donation than the remaining elements of the ECD definition. It is likely that at least a proportion of these liver-alone donors represent missed opportunities for kidney transplantation. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. Renal Transplants from Older Deceased Donors: Use of Preimplantation Biopsy and Differential Allocation to Dual or Single Kidney Transplant according to Histological Score Has No Advantages over Allocation to Single Kidney Transplant by Simple Clinical Indication.

    PubMed

    Casati, Costanza; Colombo, Valeriana Giuseppina; Perrino, Marialuisa; Rossetti, Ornella Marina; Querques, Marialuisa; Giacomoni, Alessandro; Binaggia, Agnese; Colussi, Giacomo

    2018-01-01

    Grafts from elderly donors (ECD) are increasingly allocated to single (SKT) or dual (DKT) kidney transplantation according to biopsy score. Indications and benefits of either procedure lack universal agreement. A total of 302 ECD-transplants in period from Jan 1, 2000, to Dec 31, 2015, were allocated to SKT (SKT pre ) on clinical grounds alone (before Dec 2010, pre-DKT era, n = 170) or according to a clinical-histological protocol (after Dec 2010, DKT era, n = 132) to DKT ( n = 48), SKT biopsy-based protocol ("high-risk", SKT hr , n = 51), or SKT clinically based protocol ("low-risk", SKT lr , n = 33). Graft and patient survival were compared between the two periods and between different transplant categories. Graft and overall survival in recipients from ECD in pre-DKT and DKT era did not differ (5-year graft survival 87.7% and 84.2%, resp.); equal survival in the 2 ECD periods was shown in both donor age ranges of 60-69 and >70-years, and in low-risk or high-risk ECD categories. Within the DKT protocol SKT hr showed worst graft and overall survival in the 60-69 donor age range; DKT did not result in significantly better outcome than SKT from ECD in either era. One-year posttransplant creatinine clearance in recipients did not differ between any ECD transplant category. At 3 and 5 years after transplantation there were significantly higher total dialysis-free recipient life years from an equal donor number in the pre-DKT era than in the DKT protocol. Use of a biopsy-based protocol to allocate grafts from aged donors to SKT or DKT did not result in better short term graft survival than a clinically based protocol with allocation only to SKT and reduced overall recipient dialysis-free life years in time.

  8. Renal Transplants from Older Deceased Donors: Use of Preimplantation Biopsy and Differential Allocation to Dual or Single Kidney Transplant according to Histological Score Has No Advantages over Allocation to Single Kidney Transplant by Simple Clinical Indication

    PubMed Central

    Casati, Costanza; Colombo, Valeriana Giuseppina; Perrino, Marialuisa; Rossetti, Ornella Marina; Querques, Marialuisa; Giacomoni, Alessandro; Binaggia, Agnese

    2018-01-01

    Background Grafts from elderly donors (ECD) are increasingly allocated to single (SKT) or dual (DKT) kidney transplantation according to biopsy score. Indications and benefits of either procedure lack universal agreement. Methods A total of 302 ECD-transplants in period from Jan 1, 2000, to Dec 31, 2015, were allocated to SKT (SKTpre) on clinical grounds alone (before Dec 2010, pre-DKT era, n = 170) or according to a clinical-histological protocol (after Dec 2010, DKT era, n = 132) to DKT (n = 48), SKT biopsy-based protocol (“high-risk”, SKThr, n = 51), or SKT clinically based protocol (“low-risk”, SKTlr, n = 33). Graft and patient survival were compared between the two periods and between different transplant categories. Results Graft and overall survival in recipients from ECD in pre-DKT and DKT era did not differ (5-year graft survival 87.7% and 84.2%, resp.); equal survival in the 2 ECD periods was shown in both donor age ranges of 60–69 and >70-years, and in low-risk or high-risk ECD categories. Within the DKT protocol SKThr showed worst graft and overall survival in the 60–69 donor age range; DKT did not result in significantly better outcome than SKT from ECD in either era. One-year posttransplant creatinine clearance in recipients did not differ between any ECD transplant category. At 3 and 5 years after transplantation there were significantly higher total dialysis-free recipient life years from an equal donor number in the pre-DKT era than in the DKT protocol. Conclusions Use of a biopsy-based protocol to allocate grafts from aged donors to SKT or DKT did not result in better short term graft survival than a clinically based protocol with allocation only to SKT and reduced overall recipient dialysis-free life years in time. PMID:29862061

  9. Concordance between (99m)Tc-ECD SPECT and 18F-FDG PET interpretations in patients with cognitive disorders diagnosed according to NIA-AA criteria.

    PubMed

    Ito, Kimiteru; Shimano, Yasumasa; Imabayashi, Etsuko; Nakata, Yasuhiro; Omachi, Yoshie; Sato, Noriko; Arima, Kunimasa; Matsuda, Hiroshi

    2014-10-01

    The purpose of this study was to clarify the concordance of diagnostic abilities and interobserver agreement between 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) and brain perfusion single photon-emission computed tomography (SPECT) in patients with Alzheimer's disease (AD) who were diagnosed according to the research criteria of the National Institute of Aging-Alzheimer's Association Workshop. Fifty-five patients with "AD and mild cognitive impairment (MCI)" (n = 40) and "non-AD" (n = 15) were evaluated with 18F-FDG PET and (99m)Tc-ethyl cysteinate dimer (ECD) SPECT during an 8-week period. Three radiologists independently graded the regional uptake in the frontal, temporal, parietal, and occipital lobes as well as the precuneus/posterior cingulate cortex in both images. Kappa values were used to determine the interobserver reliability regarding regional uptake. The regions with better interobserver reliability between 18F-FDG PET and (99m)Tc-ECD SPECT were the frontal, parietal, and temporal lobes. The (99m)Tc-ECD SPECT agreement in the occipital lobes was not significant. The frontal, temporal, and parietal lobes showed good correlations between 18F-FDG PET and (99m)Tc-ECD SPECT in the degree of uptake, but the occipital lobe and precuneus/posterior cingulate cortex did not show good correlations. The diagnostic accuracy rates of "AD and MCI" ranged from 60% to 70% in both of the techniques. The degree of uptake on 18F-FDG PET and (99m)Tc-ECD SPECT showed significant correlations in the frontal, temporal, and parietal lobes. The diagnostic abilities of 18F-FDG PET and (99m)Tc-ECD SPECT for "AD and MCI," when diagnosed according to the National Institute of Aging-Alzheimer's Association Workshop criteria, were nearly identical. Copyright © 2014 John Wiley & Sons, Ltd.

  10. JSATS Detector Field Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, Eric Y.; Flory, Adam E.; Lamarche, Brian L.

    2014-06-01

    The Juvenile Salmon Acoustic Telemetry System (JSATS) Detector is a software and hardware system that captures JSATS Acoustic Micro Transmitter (AMT) signals. The system uses hydrophones to capture acoustic signals in the water. This analog signal is then amplified and processed by the Analog to Digital Converter (ADC) and Digital Signal Processor (DSP) board in the computer. This board digitizes and processes the acoustic signal to determine if a possible JSATS tag is present. With this detection, the data will be saved to the computer for further analysis. This document details the features and functionality of the JSATS Detector software.more » The document covers how to install the software, setup and run the detector software. The document will also go over the raw binary waveform file format and CSV files containing RMS values« less

  11. Hearing rehabilitation with a binaural cochlear implant in a patient with Erdheim-Chester disease.

    PubMed

    Querat, Charlotte; Thai-Van, Hung; Durand, Denis Vital; Cotton, François; Gallego, Stéphane; Truy, Eric

    2015-09-01

    Erdheim-Chester disease (ECD) is a rare non-Langerhans form of histiocytosis. This paper reports an exceptional case of bilateral neural involvement, responsible for profound hearing loss. Bilateral cochlear implantation was performed. We present a 57-year-old man affected by ECD with profound bilateral hearing loss. The patient underwent cochlear implantation with a binaural Digisonic(®) cochlear implant, 7 years after the initial diagnosis. Speech intelligibility rose to a plateau after about 6 months of cochlear implant use. The average outcome of speech intelligibility over time was 55% for dissyllabic words without lip reading, and 70% for sentences. Perception score decreased before the patient died from ECD. A description of the ECD and its otological manifestations is presented. This paper reports the effective hearing rehabilitation of profound bilateral hearing loss by the means of a binaural Digisonic(®) cochlear implant.

  12. Application of an ultraminiature thermal neutron monitor for irradiation field study of accelerator-based neutron capture therapy

    PubMed Central

    Ishikawa, Masayori; Tanaka, Kenichi; Endo, Satrou; Hoshi, Masaharu

    2015-01-01

    Abstract Phantom experiments to evaluate thermal neutron flux distribution were performed using the Scintillator with Optical Fiber (SOF) detector, which was developed as a thermal neutron monitor during boron neutron capture therapy (BNCT) irradiation. Compared with the gold wire activation method and Monte Carlo N-particle (MCNP) calculations, it was confirmed that the SOF detector is capable of measuring thermal neutron flux as low as 105 n/cm2/s with sufficient accuracy. The SOF detector will be useful for phantom experiments with BNCT neutron fields from low-current accelerator-based neutron sources. PMID:25589504

  13. What role for the home learning environment and parenting in reducing the socioeconomic gradient in child development? Findings from the Millennium Cohort Study.

    PubMed

    Kelly, Y; Sacker, A; Del Bono, E; Francesconi, M; Marmot, M

    2011-09-01

    Early child health and development (ECD) is important for health in later life. Objectives were to (1) examine the extent of socioeconomic inequality in markers of ECD at ages 3 and 5 years; (2) examine whether the ECD-income gap widens between these ages; (3) assess the contribution of the home learning environment, family routines and psychosocial environment to observed inequalities in ECD. Data on socioemotional difficulties, and tests of cognitive ability in 3-year-old (n=15 382) and 5-year-old (n=15 042) children from the UK Millennium Cohort Study were used. Children in the highest income group were less likely to have socioemotional difficulties compared with those in the lowest income group at 3 and 5 years (2.4% vs 16.4% and 2.0% vs 15.9%, respectively) and had higher mean scores: age 3 'school readiness' 114 versus 99; verbal ability 54 versus 48, and age 5: verbal ability 60 versus 51, non-verbal ability 58 versus 54 and spatial ability 54 versus 48 (all p<0.001). The income gap in verbal ability scores widened between ages 3 and 5 (Wald test, p=0.04). Statistical adjustment for markers of home learning, family routines and psychosocial environments did more to explain the income gap in socioemotional difficulties than in cognitive test scores. Our results suggest that relationships between family income and markers of ECD are amenable to change. The role of home learning, family routines and psychosocial environmental factors are potentially important in closing income gaps in ECD.

  14. A Mathematical Model to Predict Endothelial Cell Density Following Penetrating Keratoplasty With Selective Dropout From Graft Failure

    PubMed Central

    Riddlesworth, Tonya D.; Kollman, Craig; Lass, Jonathan H.; Patel, Sanjay V.; Stulting, R. Doyle; Benetz, Beth Ann; Gal, Robin L.; Beck, Roy W.

    2014-01-01

    Purpose. We constructed several mathematical models that predict endothelial cell density (ECD) for patients after penetrating keratoplasty (PK) for a moderate-risk condition (principally Fuchs' dystrophy or pseudophakic/aphakic corneal edema). Methods. In a subset (n = 591) of Cornea Donor Study participants, postoperative ECD was determined by a central reading center. Various statistical models were considered to estimate the ECD trend longitudinally over 10 years of follow-up. A biexponential model with and without a logarithm transformation was fit using the Gauss-Newton nonlinear least squares algorithm. To account for correlated data, a log-polynomial model was fit using the restricted maximum likelihood method. A sensitivity analysis for the potential bias due to selective dropout was performed using Bayesian analysis techniques. Results. The three models using a logarithm transformation yield similar trends, whereas the model without the transform predicts higher ECD values. The adjustment for selective dropout turns out to be negligible. However, this is possibly due to the relatively low rate of graft failure in this cohort (19% at 10 years). Fuchs' dystrophy and pseudophakic/aphakic corneal edema (PACE) patients had similar ECD decay curves, with the PACE group having slightly higher cell densities by 10 years. Conclusions. Endothelial cell loss after PK can be modeled via a log-polynomial model, which accounts for the correlated data from repeated measures on the same subject. This model is not significantly affected by the selective dropout due to graft failure. Our findings warrant further study on how this may extend to ECD following endothelial keratoplasty. PMID:25425307

  15. Determination of organochlorine pesticides in skins and leather by gas chromatography.

    PubMed

    Font, J; Marsal, A

    1998-06-19

    The simultaneous determination of residues of lindane (gamma-HCH) and 10 other organochlorine pesticides (OCPs) in skins and leather was carried out by gas chromatography (GC) with electron-capture detection (ECD). GC with mass spectrometric detection was used to identity confirmation. Samples were extracted with hexane. The extracts were concentrated, and cleaned up on a Florisil column. Dibromooctafluorobiphenyl was added as internal standard. Hide fortifications of 0.5 an d5.0 ppm yielded average lindane recoveries of 98% and 96%, respectively. OCPs was determined in 57 samples of skins purchased from American, European and African countries in 1996-1997. OCPs were not detected in any of the American and European samples. Residues of lindane were found in 56% of African samples.

  16. Pushing the limits: Quantification of chromophores in real-world paper samples by GC-ECD and EI-GC-MS.

    PubMed

    Schedl, A; Zweckmair, T; Kikul, F; Bacher, M; Rosenau, T; Potthast, A

    2018-03-01

    Widening the methodology of chromophore analysis in pulp and paper science, a sensitive gas-chromatographic approach with electron-capture detection is presented and applied to model samples and real-world historic paper material. Trifluoroacetic anhydride was used for derivatization of the chromophore target compounds. The derivative formation was confirmed by NMR and accurate mass analysis. The method successfully detects and quantifies hydroxyquinones which are key chromophores in cellulosic matrices. The analytical figures of merit appeared to be in an acceptable range with an LOD down to approx. 60ng/g for each key chromophore, which allows for their successful detection in historic sample material. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. ELECTROCHEMICAL DEGRADATION OF PERSISTANCE POLLUTANTS IN GROUNDWATER AND SEDIMENTS

    EPA Science Inventory

    Electrochemical Degradation (ECD) utilizes redox potential at the anode and the cathode to oxidize and/or reduce organic contaminants. ECD of environmentally persistence pollutants such chlorinate solvents, PCBs, and PAHs, although theoretically possible, has not been experimenta...

  18. The use of experimental design in the development of an HPLC-ECD method for the analysis of captopril.

    PubMed

    Khamanga, Sandile M; Walker, Roderick B

    2011-01-15

    An accurate, sensitive and specific high performance liquid chromatography-electrochemical detection (HPLC-ECD) method that was developed and validated for captopril (CPT) is presented. Separation was achieved using a Phenomenex(®) Luna 5 μm (C(18)) column and a mobile phase comprised of phosphate buffer (adjusted to pH 3.0): acetonitrile in a ratio of 70:30 (v/v). Detection was accomplished using a full scan multi channel ESA Coulometric detector in the "oxidative-screen" mode with the upstream electrode (E(1)) set at +600 mV and the downstream (analytical) electrode (E(2)) set at +950 mV, while the potential of the guard cell was maintained at +1050 mV. The detector gain was set at 300. Experimental design using central composite design (CCD) was used to facilitate method development. Mobile phase pH, molarity and concentration of acetonitrile (ACN) were considered the critical factors to be studied to establish the retention time of CPT and cyclizine (CYC) that was used as the internal standard. Twenty experiments including centre points were undertaken and a quadratic model was derived for the retention time for CPT using the experimental data. The method was validated for linearity, accuracy, precision, limits of quantitation and detection, as per the ICH guidelines. The system was found to produce sharp and well-resolved peaks for CPT and CYC with retention times of 3.08 and 7.56 min, respectively. Linear regression analysis for the calibration curve showed a good linear relationship with a regression coefficient of 0.978 in the concentration range of 2-70 μg/mL. The linear regression equation was y=0.0131x+0.0275. The limits of detection (LOQ) and quantitation (LOD) were found to be 2.27 and 0.6 μg/mL, respectively. The method was used to analyze CPT in tablets. The wide range for linearity, accuracy, sensitivity, short retention time and composition of the mobile phase indicated that this method is better for the quantification of CPT than the pharmacopoeial methods. Copyright © 2010 Elsevier B.V. All rights reserved.

  19. DANCE : a 4[pi] barium fluoride detector for measuring neutron capture on unstable nuclei /.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ullmann, J. L.; Haight, Robert C.; Hunt, L. F.

    2002-01-01

    Measurements of neutron capture on unstable nuclei are important for studies of s-process nucleosynthesis, nuclear waste transmutation, and stewardship science. A 160-element, 4{pi} barium fluoride detector array, and associated neutron flight path, is being constructed to make capture measurements at the moderated neutron spallation source at LANSCE. Measurements can be made on as little as 1 mg of sample material over energies from near thermal to near 100 keV. The design of the DANCE array is described and neutron flux measurements from flight path commissioning are shown. The array is expected to be complete by the end of 2002.

  20. 56Fe capture cross section experiments at the RPI LINAC Center

    NASA Astrophysics Data System (ADS)

    McDermott, Brian; Blain, Ezekiel; Thompson, Nicholas; Weltz, Adam; Youmans, Amanda; Danon, Yaron; Barry, Devin; Block, Robert; Daskalakis, Adam; Epping, Brian; Leinweber, Gregory; Rapp, Michael

    2017-09-01

    A new array of C6D6 detectors installed at the RPI LINAC Center has enabled the capability to measure neutron capture cross sections above the 847 keV inelastic scattering threshold of 56Fe through the use of digital post-processing filters and pulse-integral discriminators, without sacrificing the statistical quality of data at lower incident neutron energies where such filtering is unnecessary. The C6D6 detectors were used to perform time-of-flight capture cross section measurements on a sample 99.87% enriched iron-56. The total-energy method, combined with the pulse height weighting technique, were then applied to the raw data to determine the energy-dependent capture yield. Above the inelastic threshold, the data were analyzed with a pulse-integral filter to reveal the capture signal, extending the the full data set to 2 MeV.

  1. Development of a thin scintillation films fission-fragment detector and a novel neutron source

    NASA Astrophysics Data System (ADS)

    Rusev, G.; Jandel, M.; Baramsai, B.; Bond, E. M.; Bredeweg, T. A.; Couture, A.; Daum, J. K.; Favalli, A.; Ianakiev, K. D.; Iliev, M. L.; Mosby, S.; Roman, A. R.; Springs, R. K.; Ullmann, J. L.; Walker, C. L.

    2015-08-01

    Investigation of prompt fission and neutron-capture Υ rays from fissile actinide samples at the Detector for Advanced Neutron Capture Experiments (DANCE) requires use of a fission-fragment detector to provide a trigger or a veto signal. A fission-fragment detector based on thin scintillating films and silicon photomultipliers has been built to serve as a trigger/veto detector in neutron-induced fission measurements at DANCE. The fissile material is surrounded by scintillating films providing a 4π detection of the fission fragments. The scintillations were registered with silicon photomultipliers. A measurement of the 235U(n,f) reaction with this detector at DANCE revealed a correct time-of-flight spectrum and provided an estimate for the efficiency of the prototype detector of 11.6(7)%. Design and test measurements with the detector are described. A neutron source with fast timing has been built to help with detector-response measurements. The source is based on the neutron emission from the spontaneous fission of 252Cf and the same type of scintillating films and silicon photomultipliers. Overall time resolution of the source is 0.3 ns. Design of the source and test measurements with it are described. An example application of the source for determining the neutron/gamma pulse-shape discrimination by a stilbene crystal is given.

  2. Independent measurement of the neutrino mixing angle θ 13 via neutron capture on hydrogen at Daya Bay

    DOE PAGES

    Jaffe, D. E.

    2014-10-03

    A new measurement of the θ 13 mixing angle has been obtained at the Daya Bay Reactor Neutrino Experiment via the detection of inverse beta decays tagged by neutron capture on hydrogen. The antineutrino events for hydrogen capture are distinct from those for gadolinium capture with largely different systematic uncertainties, allowing a determination independent of the gadolinium-capture result and an improvement on the precision of the θ 13 measurement. With a 217-day antineutrino data set obtained with six antineutrino detectors and from six 2.9 GW th reactors, the rate deficit observed at the far hall is interpreted as sin 22θmore » 13=0.083±0.018 in the three-flavor oscillation model. When combined with the gadolinium-capture result from Daya Bay, we obtain sin 22θ 13=0.089±0.008 as the final result for the six-antineutrino-detector configuration of the Daya Bay experiment.« less

  3. Extended Criteria Donors in Liver Transplantation.

    PubMed

    Vodkin, Irine; Kuo, Alexander

    2017-05-01

    Mortality rates on the liver transplant waiting list are increasing. The shortage of organs has resulted in higher utilization of extended criteria donors (ECDs), with centers pushing the limits of what is acceptable for transplantation. Donor quality is more appropriately represented as a continuum of risk, and careful selection and matching of ECD grafts with recipients may lead to excellent outcomes. Although there is no precise definition for what constitutes an ECD liver, this review focuses on frequently cited characteristics, including donor age, steatosis, donation after cardiac death, and donors with increased risk of disease transmission. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Early childhood development in Africa: interrogating constraints of prevailing knowledge bases.

    PubMed

    Pence, Alan R; Marfo, Kofi

    2008-04-01

    The past two decades have been characterized by renewed attention to the importance of early childhood development (ECD) policies and services in the world's richest and most industrialized countries. During the same period, we have witnessed unprecedented efforts to place ECD policies on the national development planning agenda of the economically less advantaged countries of the Majority World. This paper is premised on the concern that the purposes that have led bilateral and multilateral international agencies to promote and support ECD services in Africa may also be paving the way for uncritical adoption of program and service delivery models grounded in value systems and knowledge bases that may not be appropriate for the continent. We present two critiques to highlight the dangers of ignoring the sociocultural contexts of the knowledge bases that inform ECD policies and practices. We describe one capacity-building effort, under the auspices of the Early Childhood Development Virtual University (ECDVU), to promote culturally relevant knowledge and prepare leadership personnel for Africa's emerging ECD movement. Finally, based on an exercise designed for an ECDVU cohort to engage and reflect on critiques of mainstream research and theorizing on child development, we share insights that are suggestive of the ways in which African perspectives can contribute to and enrich a global knowledge base on child development.

  5. Crystal Structure of the PAC1R Extracellular Domain Unifies a Consensus Fold for Hormone Recognition by Class B G-Protein Coupled Receptors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumar, Shiva; Pioszak, Augen; Zhang, Chenghai

    2012-02-21

    Pituitary adenylate cyclase activating polypeptide (PACAP) is a member of the PACAP/glucagon family of peptide hormones, which controls many physiological functions in the immune, nervous, endocrine, and muscular systems. It activates adenylate cyclase by binding to its receptor, PAC1R, a member of class B G-protein coupled receptors (GPCR). Crystal structures of a number of Class B GPCR extracellular domains (ECD) bound to their respective peptide hormones have revealed a consensus mechanism of hormone binding. However, the mechanism of how PACAP binds to its receptor remains controversial as an NMR structure of the PAC1R ECD/PACAP complex reveals a different topology ofmore » the ECD and a distinct mode of ligand recognition. Here we report a 1.9 {angstrom} crystal structure of the PAC1R ECD, which adopts the same fold as commonly observed for other members of Class B GPCR. Binding studies and cell-based assays with alanine-scanned peptides and mutated receptor support a model that PAC1R uses the same conserved fold of Class B GPCR ECD for PACAP binding, thus unifying the consensus mechanism of hormone binding for this family of receptors.« less

  6. X-ray crystallographic studies of the extracellular domain of the first plant ATP receptor, DORN1, and the orthologous protein from Camelina sativa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Zhijie; Chakraborty, Sayan; Xu, Guozhou

    Does not respond to nucleotides 1 (DORN1) has recently been identified as the first membrane-integral plant ATP receptor, which is required for ATP-induced calcium response, mitogen-activated protein kinase activation and defense responses inArabidopsis thaliana. In order to understand DORN1-mediated ATP sensing and signal transduction, crystallization and preliminary X-ray studies were conducted on the extracellular domain of DORN1 (atDORN1-ECD) and that of an orthologous protein,Camelina sativalectin receptor kinase I.9 (csLecRK-I.9-ECD or csI.9-ECD). A variety of deglycosylation strategies were employed to optimize the glycosylated recombinant atDORN1-ECD for crystallization. In addition, the glycosylated csI.9-ECD protein was crystallized at 291 K. X-ray diffraction datamore » were collected at 4.6 Å resolution from a single crystal. The crystal belonged to space groupC222 orC222 1, with unit-cell parametersa= 94.7,b= 191.5,c= 302.8 Å. These preliminary studies have laid the foundation for structural determination of the DORN1 and I.9 receptor proteins, which will lead to a better understanding of the perception and function of extracellular ATP in plants.« less

  7. The Influence of Maternal and Household Resources, and Parental Psychosocial Child Stimulation on Early Childhood Development: A Cross-Sectional Study of Children 36⁻59 Months in Honduras.

    PubMed

    Urke, Helga Bjørnøy; Contreras, Mariela; Matanda, Dennis Juma

    2018-05-07

    Optimal early childhood development (ECD) is currently jeopardized for more than 250 million children under five in low- and middle-income countries. The Sustainable Development Goals has called for a renewed emphasis on children’s wellbeing, encompassing a holistic approach that ensures nurturing care to facilitate optimal child development. In vulnerable contexts, the extent of a family’s available resources can influence a child’s potential of reaching its optimal development. Few studies have examined these relationships in low- and middle-income countries using nationally representative samples. The present paper explored the relationships between maternal and paternal psychosocial stimulation of the child as well as maternal and household resources and ECD among 2729 children 36⁻59 months old in Honduras. Data from the Demographic and Health Surveys conducted in 2011⁻2012 was used. Adjusted logistic regression analyses showed that maternal psychosocial stimulation was positively and significantly associated with ECD in the full, rural, and lowest wealth quintile samples. These findings underscore the importance of maternal engagement in facilitating ECD but also highlight the role of context when designing tailored interventions to improve ECD.

  8. An evaluation of kurtosis beamforming in magnetoencephalography to localize the epileptogenic zone in drug resistant epilepsy patients.

    PubMed

    Hall, Michael B H; Nissen, Ida A; van Straaten, Elisabeth C W; Furlong, Paul L; Witton, Caroline; Foley, Elaine; Seri, Stefano; Hillebrand, Arjan

    2018-06-01

    Kurtosis beamforming is a useful technique for analysing magnetoencephalograpy (MEG) data containing epileptic spikes. However, the implementation varies and few studies measure concordance with subsequently resected areas. We evaluated kurtosis beamforming as a means of localizing spikes in drug-resistant epilepsy patients. We retrospectively applied kurtosis beamforming to MEG recordings of 22 epilepsy patients that had previously been analysed using equivalent current dipole (ECD) fitting. Virtual electrodes were placed in the kurtosis volumetric peaks and visually inspected to select a candidate source. The candidate sources were compared to the ECD localizations and resection areas. The kurtosis beamformer produced interpretable localizations in 18/22 patients, of which the candidate source coincided with the resection lobe in 9/13 seizure-free patients and in 3/5 patients with persistent seizures. The sublobar accuracy of the kurtosis beamformer with respect to the resection zone was higher than ECD (56% and 50%, respectively), however, ECD resulted in a higher lobar accuracy (75%, 67%). Kurtosis beamforming may provide additional value when spikes are not clearly discernible on the sensors and support ECD localizations when dipoles are scattered. Kurtosis beamforming should be integrated with existing clinical protocols to assist in localizing the epileptogenic zone. Copyright © 2018 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  9. A wide linear range Eddy Current Displacement Sensor equipped with dual-coil probe applied in the Magnetic Suspension Flywheel.

    PubMed

    Fang, Jiancheng; Wen, Tong

    2012-01-01

    The Eddy Current Displacement Sensor (ECDS) is widely used in the Magnetic Suspension Flywheel (MSFW) to measure the tiny clearance between the rotor and the magnetic bearings. The linear range of the ECDS is determined by the diameter of its probe coil. Wide clearances must be measured in some new MSFWs recently designed for the different space missions, but the coil diameter is limited by some restrictions. In this paper, a multi-channel ECDS equipped with dual-coil probes is proposed to extend the linear range to satisfy the demands of such MSFWs. In order to determine the best configuration of the dual-coil probe, the quality factors of the potential types of the dual-coil probes, the induced eddy current and the magnetic intensity on the surface of the measuring object are compared with those of the conventional single-coil probe. The linear range of the ECDS equipped with the selected dual-coil probe is extended from 1.1 mm to 2.4 mm under the restrictions without adding any cost for additional compensation circuits or expensive coil materials. The effectiveness of the linear range extension ability and the dynamic response of the designed ECDS are confirmed by the testing and the applications in the MSFW.

  10. Evaluation of various soaking agents as a novel tool for pesticide residues mitigation from cauliflower (Brassica oleracea var. botrytis).

    PubMed

    Abdullah; Randhawa, Muhammad Atif; Asghar, Ali; Pasha, Imran; Usman, Rabia; Shamoon, Muhammad; Bhatti, Muhammad Arslan; Irshad, Muhammad Asim; Ahmad, Naveed

    2016-08-01

    The increasing use of pesticides for boosting the yield of agricultural crops also impart toxic residues which ultimately extend to numerous physiological disorders upon consumption. The present study was designed as an effort to assess the reduction potential of various chemical solutions and to minimize the pesticide residues in cauliflower ( Brassica oleracea var. botrytis ). The samples were soaked in various solutions along with tap water to mitigate pesticide residues. Afterwards, the extracted supernatant was passed through column containing anhydrous sodium sulfate trailed by activated carbon for clean-up. Eluents were first evaporated and then completely dried under gentle stream of Nitrogen. Finally, the residues were determined using gas chromatography equipped with electron capture detector (GC-ECD). Results revealed the highest reduction of endosulfan, bifenthrin and cypermethrin residues with acetic acid (10 %) was 1.133 ± 0.007 (41 %), 0.870 ± 0.022 (60 %) and 0.403 ± 0.003 (75 %), respectively among the tested solutions. However, simple tap water treatment also resulted in 0.990 ± 0.02 (12 %), 1.323 ± 0.015 (14 %) and 1.274 ± 0.002 (21 %) elimination of endosulfan, bifenthrin and cypermethrin residues, respectively. Moreover, among various solutions, acetic acid depicted maximum reduction potential followed by citric acid, hydrogen peroxide, sodium chloride and sodium carbonate solutions. The percent reduction by various solutions ranged from 12 to 41, 14 to 60 and 21 to 75 % for the elimination of endosulfan, bifenthrin and cypermethrin residues, respectively.

  11. Levels of select organophosphates in human colostrum and mature milk samples in rural region of Faizabad district, Uttar Pradesh, India.

    PubMed

    Srivastava, S; Narvi, S S; Prasad, S C

    2011-10-01

    Human colostrum and mature milk samples from rural mothers were separately screened for organophosphate pesticides (OPPs). The samples were assessed for the pollution load they are transmitting to the nursing infant to determine potential toxicity. The role of colostrum for toxicity monitoring was assessed in comparison to mature milk as it is the very first infant food. The pesticides were quantified using a Gas Chromatograph equipped with Electron Capture Detector (GC-ECD) and the results were further validated on GC linked with Mass Spectrophotometer (GC-MS) and Fourier transform infrared (FTIR). A total of 33 samples were analyzed out of 40 samples collected. These samples were from 33 mothers. Out of these, 25 were colostrum samples and 8 were mature milk samples. Frequency percentage (N%) of organophosphates analyzed was highest for ethion (23.1% or 6/26) in colostrum and chlorpyrifos (50% or 4/8) in mature milk samples. Frequency percentage in colostrum was 19.2% (5/26) for chlorpyrifos and 3.8% (1/26) for dimethoate; 25.0% (2/8) mature milk samples carried dimethoate and 12.5% (1/8) carried ethion. Mean OPPs in colostrum: dimethoate (85.888 ng/g fat) > ethion (48.000 ng/g fat) > chlorpyrifos (4.003 ng/g fat); and mature milk: ethion (744.925 ng/g fat) > chlorpyrifos (37.274 ng/g fat) > dimethoate (26.752 ng/g fat). MS data revealed the presence of methyl parathion, which was not quantitated. None of the samples exceeded acceptable daily intake standards set by Joint Meeting on Pesticide Residues (JMPR). The study will pave way for further analysis on pesticide toxicology.

  12. Tunable generation and adsorption of energetic compounds in the vapor phase at trace levels: a tool for testing and developing sensitive and selective substrates for explosive detection.

    PubMed

    Bonnot, Karine; Bernhardt, Pierre; Hassler, Dominique; Baras, Christian; Comet, Marc; Keller, Valérie; Spitzer, Denis

    2010-04-15

    Among various methods for landmine detection, as well as soil and water pollution monitoring, the detection of explosive compounds in air is becoming an important and inevitable challenge for homeland security applications, due to the threatening increase in terrorist explosive bombs used against civil populations. However, in the last case, there is a crucial need for the detection of vapor phase traces or subtraces (in the ppt range or even lower). A novel and innovative generator for explosive trace vapors was designed and developed. It allowed the generation of theoretical concentrations as low as 0.24 ppq for hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in air according to Clapeyron equations. The accurate generation of explosive concentrations at subppt levels was verified for RDX and 2,4,6-trinitrotoluene (TNT) using a gas chromatograph coupled to an electron capture detector (GC-ECD). First, sensing material experiments were conducted on a nanostructured tungsten oxide. The sensing efficiency of this material determined as its adsorption capacity toward 54 ppb RDX was calculated to be five times higher than the sensing efficiency of a 54 ppb TNT vapor. The material sensing efficiency showed no dependence on the mass of material used. The results showed that the device allowed the calibration and discrimination between materials for highly sensitive and accurate sensing detection in air of low vapor pressure explosives such as TNT or RDX at subppb levels. The designed device and method showed promising features for nanosensing applications in the field of ultratrace explosive detection. The current perspectives are to decrease the testing scale and the detection levels to ppt or subppt concentration of explosives in air.

  13. Transport of explosives I: TNT in soil and its equilibrium vapor

    NASA Astrophysics Data System (ADS)

    Baez, Bibiana; Correa, Sandra N.; Hernandez-Rivera, Samuel P.; de Jesus, Maritza; Castro, Miguel E.; Mina, Nairmen; Briano, Julio G.

    2004-09-01

    Landmine detection is an important task for military operations and for humanitarian demining. Conventional methods for landmine detection involve measurements of physical properties. Several of these methods fail on the detection of modern mines with plastic enclosures. Methods based on the detection signature explosives chemicals such as TNT and DNT are specific to landmines and explosive devices. However, such methods involve the measurements of the vapor trace, which can be deceiving of the actual mine location because of the complex transport phenomena that occur in the soil neighboring the buried landmine. We report on the results of the study of the explosives subject to similar environmental conditions as the actual mines. Soil samples containing TNT were used to study the effects of aging, temperature and moisture under controlled conditions. The soil used in the investigation was Ottawa sand. A JEOL GCMate II gas chromatograph +/- mass spectrometer coupled to a Tunable Electron Energy Monochromator (TEEM-GC/MS) was used to develop the method of analysis of explosives under enhanced detection conditions. Simultaneously, a GC with micro cell 63Ni, Electron Capture Detector (μECD) was used for analysis of TNT in sand. Both techniques were coupled with Solid-Phase Micro Extraction (SPME) methodology to collect TNT doped sand samples. The experiments were done in both, headspace and immersion modes of SPME for sampling of explosives. In the headspace experiments it was possible to detect appreciable TNT vapors as early as 1 hour after of preparing the samples, even at room temperature (20 °C). In the immersion experiments, I-SPME technique allowed for the detection of concentrations as low as 0.010 mg of explosive per kilogram of soil.

  14. Adsorption behavior of alpha -cypermethrin on cork and activated carbon.

    PubMed

    Domingues, Valentina F; Priolo, Giuseppe; Alves, Arminda C; Cabral, Miguel F; Delerue-Matos, Cristina

    2007-08-01

    Studies were undertaken to determine the adsorption behavior of alpha -cypermethrin [R)-alpha -cyano-3-phenoxybenzyl(1S)-cis-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropanecarboxylate, and (S)-alpha-cyano-3-phenoxybenzyl (1R)-cis-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropanecarboxylate] in solutions on granules of cork and activated carbon (GAC). The adsorption studies were carried out using a batch equilibrium technique. A gas chromatograph with an electron capture detector (GC-ECD) was used to analyze alpha -cypermethrin after solid phase extraction with C18 disks. Physical properties including real density, pore volume, surface area and pore diameter of cork were evaluated by mercury porosimetry. Characterization of cork particles showed variations thereby indicating the highly heterogeneous structure of the material. The average surface area of cork particles was lower than that of GAC. Kinetics adsorption studies allowed the determination of the equilibrium time - 24 hours for both cork (1-2 mm and 3-4 mm) and GAC. For the studied alpha -cypermethrin concentration range, GAC revealed to be a better sorbent. However, adsorption parameters for equilibrium concentrations, obtained through the Langmuir and Freundlich models, showed that granulated cork 1-2 mm have the maximum amount of adsorbed alpha-cypermethrin (q(m)) (303 microg/g); followed by GAC (186 microg/g) and cork 3-4 mm (136 microg/g). The standard deviation (SD) values, demonstrate that Freundlich model better describes the alpha -cypermethrin adsorption phenomena on GAC, while alpha -cypermethrin adsorption on cork (1-2 mm and 3-4 mm) is better described by the Langmuir. In view of the adsorption results obtained in this study it appears that granulated cork may be a better and a cheaper alternative to GAC for removing alpha -cypermethrin from water.

  15. Air-assisted liquid-liquid microextraction by solidifying the floating organic droplets for the rapid determination of seven fungicide residues in juice samples.

    PubMed

    You, Xiangwei; Xing, Zhuokan; Liu, Fengmao; Zhang, Xu

    2015-05-22

    A novel air assisted liquid-liquid microextraction using the solidification of a floating organic droplet method (AALLME-SFO) was developed for the rapid and simple determination of seven fungicide residues in juice samples, using the gas chromatography with electron capture detector (GC-ECD). This method combines the advantages of AALLME and dispersive liquid-liquid microextraction based on the solidification of floating organic droplets (DLLME-SFO) for the first time. In this method, a low-density solvent with a melting point near room temperature was used as the extraction solvent, and the emulsion was rapidly formed by pulling in and pushing out the mixture of aqueous sample solution and extraction solvent for ten times repeatedly using a 10-mL glass syringe. After centrifugation, the extractant droplet could be easily collected from the top of the aqueous samples by solidifying it at a temperature lower than the melting point. Under the optimized conditions, good linearities with the correlation coefficients (γ) higher than 0.9959 were obtained and the limits of detection (LOD) varied between 0.02 and 0.25 μgL(-1). The proposed method was applied to determine the target fungicides in juice samples and acceptable recoveries ranged from 72.6% to 114.0% with the relative standard deviations (RSDs) of 2.3-13.0% were achieved. Compared with the conventional DLLME method, the newly proposed method will neither require a highly toxic chlorinated solvent for extraction nor an organic dispersive solvent in the application process; hence, it is more environmentally friendly. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Antidepressant-like effect of essential oil isolated from Toona ciliata Roem. var. yunnanensis.

    PubMed

    Duan, Dongmei; Chen, Liping; Yang, Xiuyan; Tu, Ya; Jiao, Shuang

    2015-04-01

    Depressive order is one of the most common psychiatric diseases, and Toona ciliata Roem. var. yunnanensis has shown many bioactivities in folk medicine. This study was designed to investigate the antidepressant-like effect of essential oil isolated from T. ciliata Roem. var. yunnanensis. Gas chromatography and mass spectrometry (GC-MS) was used to analyze the compositions of essential oil. The immobility time in the forced swimming test (FST), tail suspending test (TST), and open field test (OFT) were used to evaluate the antidepressive effects of essential oil. Furthermore, chronic mild stress (CMS) rats were established, and contents of dopamine (DA), norepinephrine (NE), and 5-hydroxytryptamine (5-HT) in the brain were determined by high-performance liquid chromatography-electron capture detector (HPLC-ECD). Western blotting was performed to investigate the effects of essential oil on the expressions of brain-derived neurotrophic factor (BDNF) protein in rats' brain. The GC-MS analysis showed that the main components of essential oil were estragole (6.16 %), β-elemene (24.91 %), β-cubebene (14.29 %), and γ-elemene (8.05 %). The results from the FST and TST demonstrated that the immobility time could be significantly reduced by essential oil (10, 20, 40, and 80 mg/kg), without accompanying changes in ambulation when assessed in the OFT. Additionally, the contents of DA, NE, 5-HT, and BDNF in the hippocampus of CMS rats could be increased by treatment with essential oil at doses of 20, 40, and 80 mg/kg. All these results suggested that essential oil could be considered as a new candidate for curing depressive disorders.

  17. Mycoflora and mycotoxin contamination of Roundup Ready soybean harvested in the Pampean Region, Argentina.

    PubMed

    Garrido, Carolina E; González, Héctor H L; Salas, María Paula; Resnik, Silvia L; Pacin, Ana M

    2013-08-01

    A total of 89 freshly harvested soybean seed samples (Roundup Ready [transgenic] soybean cultivars) from the 2010/2011 crop season were collected from five locations in the Northern Pampean Region II, Argentina. These samples were analyzed for internal mycoflora, toxin production of isolated fungi, and for a range of mycotoxins. Mycotoxin analysis of aflatoxins (AFs), zearalenone (ZEA), fumonisins (FBs) and ochratoxin A (OTA) was done by HPLC-FLD (high performance liquid chromatography with postcolumn fluorescence derivatization), alternariol and alternariol monomethyl ether with HPLC-UV (HPLC with UV detection), trichothecenes (deoxynivalenol, nivalenol, T-2 toxin, HT-2 toxin, fusarenon X, 3-acetyldeoxynivalenol and 15-acetyldeoxynivalenol were analyzed by GC-ECD (gas chromatography with electron capture detector). Fungal colonization was more frequently found for samples from América, Saladillo and Trenque Lauquen than for samples from General Villegas and Trenel; a total of 1,401 fungal isolates were obtained from the soybean seeds. The most commonly identified fungal genera were Alternaria, Sclerotinia, Chaetomium, Cladosporium, Aspergillus, Penicillium, Phomopsis and Fusarium. Alternaria alternata, A.tenuissima, Aspergillus flavus, Penicillium citrinum, Fusarium verticillioides and F.semitectum were the predominant toxigenic fungal species. Mycotoxin production was confirmed for several isolates of toxigenic species, including Aspergillus flavus, A. parasiticus, Alternaria alternata, A.tenuissima, Fusarium graminearum, F semitectum and F. verticillioides. In particular, the percentage of mycotoxigenic Alternaria alternata (100%), A.tenuissima (95%) and aflatoxigenic strains of A. flavus (57%) were remarkably high. Although none of the mycotoxins, AFs, ZEA, FBs, trichothecenes and OTA, were directly detected in samples of soybean seeds, the frequent presence of toxigenic fungal species indicates the risk of multiple mycotoxin contamination.

  18. Single and double capture in F9+ + Ar collisions: Comparison of total capture with capture occurring from the Ar K shell

    NASA Astrophysics Data System (ADS)

    La Mantia, David; Kumara, Nuwan; Kayani, Asghar; Simon, Anna; Tanis, John

    2016-05-01

    Total cross sections for single and double capture, as well as the corresponding cross sections for capture resulting in the emission of an Ar K x ray, were measured. This work was performed at Western Michigan University with the use of the tandem Van de Graaff accelerator. A 45 MeV beam of fully-stripped fluorine ions was collided with argon gas molecules in a differentially pumped cell. Surface barrier detectors were used to observe the charge changed projectiles and a Si(Li) x-ray detector, placed at 90o to the incident beam, were used to measure coincidences with Ar K x rays. The total capture cross sections are compared to previously measured cross sections in the existing literature. The coincidence cross sections, considerably smaller than the total cross sections, are found to be nearly equal for single and double capture in contrast to the total cross sections, which vary by about an order of magnitude. Possible reasons for this behavior are discussed. Supported in part by the NSF.

  19. Modeling the Complexities of Water and Hygiene in Limpopo Province South Africa

    NASA Astrophysics Data System (ADS)

    Mellor, J. E.; Smith, J. A.; Learmonth, G.; Netshandama, V.; Dillingham, R.

    2012-12-01

    Access to sustainable water and sanitation services is one of the biggest challenges the developing world faces as an increasing number of people inhabit those areas. Inadequate access to water and sanitation infrastructure often leads children to drink poor quality water which can result in early childhood diarrhea (ECD). Repeated episodes of ECD can cause serious problems such as growth stunting, cognitive impairment, and even death. Although researchers have long studied the connection between poor access to water and hygiene facilities and ECD, most studies have relied on intervention-control methods to study the effects of singular interventions. Such studies are time-consuming, costly, and fail to acknowledge that the causes and prevention strategies for ECD are numerous and complex. An alternate approach is to think of a community as a complex system in which the engineered, natural and social environments interact in ways that are not easily predicted. Such complex systems have no central or coordinating mechanism and may exhibit emergent behavior which can be counterintuitive and lead to valuable insights. The goal of this research is to develop a robust, quantitative understanding of the complex pathogen transmission chain that leads to ECD. To realize this goal, we have developed an Agent-Based Model (ABM) which simulates individual community member behavior. We have validated this transdisciplinary model with four years of field data from a community in Limpopo Province, South Africa. Our model incorporates data such as household water source preferences, collection habits, household- and source-water quality, water-source reliability and biological regrowth. Our outcome measures are household water quality, ECD incidences, and child growth stunting. This technique allows us to test hypotheses on the computer. Future researchers can implement promising interventions with our partner institution, the University of Venda, and the model can be refined as the results of those interventions become available. Our model accurately reproduces current pathogen transport through the communities and child growth stunting. An intensive sensitivity analysis found that biological regrowth, biofilm layers and collection habits are all factors in pathogen transmission. We also report on the effects of multiple interventions and our exploration of emergent behavior. Our results indicate that the dominant source of fecal-oral transmission is through the contamination of drinking water after collection, but before consumption. Furthermore sub-optimal interventions such as improved, but still inconsistent water treatment have little protective effect against ECD. Finally, interventions such as the introduction of point-of-use water treatment technologies or improved water-storage practices are the best ECD prevention strategies. The complexities of the causes and prevention strategies of pathogen loading and ECD in the developing world are poorly understood. This project goes beyond previous studies through its ability to model the complex engineered/natural/social pathogen transmission chain using an ABM informed by field data. We hope that this and similar tools may be used by scientists, policy-makers and humanitarian organizations when designing community-level interventions to prevent ECD in similar settings around the world.

  20. High Dynamic Range Pixel Array Detector for Scanning Transmission Electron Microscopy.

    PubMed

    Tate, Mark W; Purohit, Prafull; Chamberlain, Darol; Nguyen, Kayla X; Hovden, Robert; Chang, Celesta S; Deb, Pratiti; Turgut, Emrah; Heron, John T; Schlom, Darrell G; Ralph, Daniel C; Fuchs, Gregory D; Shanks, Katherine S; Philipp, Hugh T; Muller, David A; Gruner, Sol M

    2016-02-01

    We describe a hybrid pixel array detector (electron microscope pixel array detector, or EMPAD) adapted for use in electron microscope applications, especially as a universal detector for scanning transmission electron microscopy. The 128×128 pixel detector consists of a 500 µm thick silicon diode array bump-bonded pixel-by-pixel to an application-specific integrated circuit. The in-pixel circuitry provides a 1,000,000:1 dynamic range within a single frame, allowing the direct electron beam to be imaged while still maintaining single electron sensitivity. A 1.1 kHz framing rate enables rapid data collection and minimizes sample drift distortions while scanning. By capturing the entire unsaturated diffraction pattern in scanning mode, one can simultaneously capture bright field, dark field, and phase contrast information, as well as being able to analyze the full scattering distribution, allowing true center of mass imaging. The scattering is recorded on an absolute scale, so that information such as local sample thickness can be directly determined. This paper describes the detector architecture, data acquisition system, and preliminary results from experiments with 80-200 keV electron beams.

  1. Tissue quality of eye-bank-prepared precut corneas for Descemet's stripping automated endothelial keratoplasty.

    PubMed

    Nelson, Brian A; Ritenour, Rusty J

    2014-02-01

    To evaluate endothelial cell density (ECD) of eye-bank-prepared tissue for use in Descemet's stripping automated endothelial keratoplasty (DSAEK). Prospective case series of consecutive corneal tissue prepared for DSAEK surgery. Sixty-seven sequential corneal-scleral tissue specimens representing 48 human donors processed for use in DSAEK surgery by the Regional Tissue Bank (Halifax, Nova Scotia). Corneal-scleral donor tissue was obtained by in situ recovery. ECD was recorded using the EB-3000 XYZ (HAI Laboratories Inc, Lexington, MA) specular microscope within 24 hours of preservation. Before the tissue was dissected, the corneal thickness was measured using the DGH-550 PACHETTE 2 (DGH Technology, Exton, PA) ultrasound pachymeter. The dissection was performed using a 300-μm Moria ALTK model microkeratome (Moria Inc). The posterior bed thickness was measured, and the anterior flap was replaced. Endothelial cell count density was obtained after re-preservation. Complete measurements were obtained for 42 of 67 corneas. In 25 corneas it was not possible to obtain a postdissection ECD measurement. The mean ECD before dissection was 2806 ± 317 cells/mm(2). The mean ECD after dissection was 2772 ± 318 cells/mm(2). There was an average loss of 34 cells/mm(2) (95% CI -110 to 40 cells/mm(2), p = 0.3). This case series confirms that ECD is preserved when DSAEK tissue is prepared in advance of surgery by trained eye-bank technicians in a low-volume Canadian eye bank. It was difficult to obtain clear images of the endothelial cell layer postdissection, possibly because of tissue swelling or distortion. Sixty-six of 67 corneas included in the study were used for surgery. © 2013 Canadian Ophthalmological Society Published by Canadian Ophthalmological Society All rights reserved.

  2. Development of a clinical static and dynamic standing balance measurement tool appropriate for use in adolescents.

    PubMed

    Emery, Carolyn A; Cassidy, J David; Klassen, Terry P; Rosychuk, Rhonda J; Rowe, Brian B

    2005-06-01

    There is a need in sports medicine for a static and dynamic standing balance measure to quantify balance ability in adolescents. The purposes of this study were to determine the test-retest reliability of timed static (eyes open) and dynamic (eyes open and eyes closed) unipedal balance measurements and to examine factors associated with balance. Adolescents (n=123) were randomly selected from 10 Calgary high schools. This study used a repeated-measures design. One rater measured unipedal standing balance, including timed eyes-closed static (ECS), eyes-open dynamic (EOD), and eyes-closed dynamic (ECD) balance at baseline and 1 week later. Dynamic balance was measured on a foam surface. Reliability was examined using both intraclass correlation coefficients (ICCs) and Bland and Altman statistical techniques. Multiple linear regressions were used to examine other potentially influencing factors. Based on ICCs, test-retest reliability was adequate for ECS, EOD, and ECD balance (ICC=.69, .59, and .46, respectively). The results of Bland and Altman methods, however, suggest that caution is required in interpreting reliability based on ICCs alone. Although both ECS balance and ECD balance appear to demonstrate adequate test-retest reliability by ICC, Bland and Altman methods of agreement demonstrate sufficient reliability for ECD balance only. Thirty percent of the subjects reached the 180-second maximum on EOD balance, suggesting that this test is not appropriate for use in this population. Balance ability (ECS and ECD) was better in adolescents with no past history of lower-extremity injury. Timed ECD balance is an appropriate and reliable clinical measurement for use in adolescents and is influenced by previous injury.

  3. N-Glycosylation of Asparagine 130 in the Extracellular Domain of the Human Calcitonin Receptor Significantly Increases Peptide Hormone Affinity.

    PubMed

    Lee, Sang-Min; Booe, Jason M; Gingell, Joseph J; Sjoelund, Virginie; Hay, Debbie L; Pioszak, Augen A

    2017-07-05

    The calcitonin receptor (CTR) is a class B G protein-coupled receptor that is activated by the peptide hormones calcitonin and amylin. Calcitonin regulates bone remodeling through CTR, whereas amylin regulates blood glucose and food intake by activating CTR in complex with receptor activity-modifying proteins (RAMPs). These receptors are targeted clinically for the treatment of osteoporosis and diabetes. Here, we define the role of CTR N-glycosylation in hormone binding using purified calcitonin and amylin receptor extracellular domain (ECD) glycoforms and fluorescence polarization/anisotropy and isothermal titration calorimetry peptide-binding assays. N-Glycan-free CTR ECD produced in Escherichia coli exhibited ∼10-fold lower peptide affinity than CTR ECD produced in HEK293T cells, which yield complex N-glycans, or in HEK293S GnTI - cells, which yield core N-glycans (Man 5 GlcNAc 2 ). PNGase F-catalyzed removal of N-glycans at N73, N125, and N130 in the CTR ECD decreased peptide affinity ∼10-fold, whereas Endo H-catalyzed trimming of the N-glycans to single GlcNAc residues had no effect on peptide binding. Similar results were observed for an amylin receptor RAMP2-CTR ECD complex. Characterization of peptide-binding affinities of purified N → Q CTR ECD glycan site mutants combined with PNGase F and Endo H treatment strategies and mass spectrometry to define the glycan species indicated that a single GlcNAc residue at CTR N130 was responsible for the peptide affinity enhancement. Molecular modeling suggested that this GlcNAc functions through an allosteric mechanism rather than by directly contacting the peptide. These results reveal an important role for N-linked glycosylation in the peptide hormone binding of a clinically relevant class B GPCR.

  4. Structural Basis for Hormone Recognition by the Human CRFR2[alpha] G Protein-coupled Receptor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pal, Kuntal; Swaminathan, Kunchithapadam; Xu, H. Eric

    2012-05-09

    The mammalian corticotropin releasing factor (CRF)/urocortin (Ucn) peptide hormones include four structurally similar peptides, CRF, Ucn1, Ucn2, and Ucn3, that regulate stress responses, metabolism, and cardiovascular function by activating either of two related class B G protein-coupled receptors, CRFR1 and CRFR2. CRF and Ucn1 activate both receptors, whereas Ucn2 and Ucn3 are CRFR2-selective. The molecular basis for selectivity is unclear. Here, we show that the purified N-terminal extracellular domains (ECDs) of human CRFR1 and the CRFR2{alpha} isoform are sufficient to discriminate the peptides, and we present three crystal structures of the CRFR2{alpha} ECD bound to each of the Ucn peptides.more » The CRFR2{alpha} ECD forms the same fold observed for the CRFR1 and mouse CRFR2{beta} ECDs but contains a unique N-terminal {alpha}-helix formed by its pseudo signal peptide. The CRFR2{alpha} ECD peptide-binding site architecture is similar to that of CRFR1, and binding of the {alpha}-helical Ucn peptides closely resembles CRF binding to CRFR1. Comparing the electrostatic surface potentials of the ECDs suggests a charge compatibility mechanism for ligand discrimination involving a single amino acid difference in the receptors (CRFR1 Glu104/CRFR2{alpha} Pro-100) at a site proximate to peptide residue 35 (Arg in CRF/Ucn1, Ala in Ucn2/3). CRFR1 Glu-104 acts as a selectivity filter preventing Ucn2/3 binding because the nonpolar Ala-35 is incompatible with the negatively charged Glu-104. The structures explain the mechanisms of ligand recognition and discrimination and provide a molecular template for the rational design of therapeutic agents selectively targeting these receptors.« less

  5. Early Childhood Development and Iranian Parents' Knowledge: A Qualitative Study.

    PubMed

    Habibi, Elham; Sajedi, Firouzeh; Afzali, Hosein Malek; Hatamizadeh, Nikta; Shahshahanipour, Soheila; Glascoe, Frances Page

    2017-01-01

    Early childhood is the most important step throughout the lifespan and it is a critical period continuing to the end of 8-year-old. Mothers' knowledge is one of the important aspects of child development. The goals of this study were to determine the situation of knowledge in Iranian parents about the concept and the importance of early childhood development (ECD) and determining the sources of parental knowledge about ECD from the perspective of parents and grandparents. This qualitative study was conducted based on the directional content analysis in 2016. The purposive sampling method is utilized to select 24 participants among parents and grandparents in Tehran. The inclusion criteria consisted of speaking in Persian and having a child or grandchild <3-year-old. Data were collected through four focus group discussions and four individual interviews. Iranian parental knowledge about integrative ECD is not enough, their knowledge about motor development and speech and language are relatively better, about cognitive development is little and socialemotional is very little. They said parents and other caregivers influence the process of children's development. Parents' knowledge resources about ECD included human resources, physical resources, virtual space, and the media. According to the majority of participants, "pediatricians are the most reliable source of parents' knowledge about ECD" even though the main focus of pediatricians is on treating diseases, physical health, and growth of children. According to the results, the knowledge of Iranian parent is not enough about ECD; therefore, actions must be taken to increase their knowledge in these domains. Parents look for reliable and valid sources to enhance their knowledge and they rely the most on pediatricians in this regard. Therefore, more studies on assessing parents' knowledge in community and the practical methods for knowledge promotion in this field is recommended.

  6. Creating leptin-like biofunctions by active immunization against chicken leptin receptor in growing chickens.

    PubMed

    Lei, M M; Wu, S Q; Shao, X B; Li, X W; Chen, Z; Ying, S J; Shi, Z D

    2015-01-01

    In this study, immunization against chicken leptin receptor (cLEPR) extracellular domain (ECD) was applied to investigate leptin regulation and LEPR biofunction in growing chicken pullets. A recombinant protein (cLEPR ECD) based on the cLEPR complemenary DNA sequence corresponding to the 582nd to 796th amino acid residues of cLEPR mature peptide was prepared and used as antigen. Immunization against cLEPR ECD in growing chickens increased anti-cLEPR ECD antibody titers in blood, enhanced proportions of phosphorylated janus kinase 2 (JAK2) and served as signal transducer and activator of transcription 3 (STAT3) protein in liver tissue. Chicken live weight gain and abdominal fat mass were significantly decreased (P < 0.05), but feed intake was stimulated by cLEPR ECD immunization (P < 0.05). The treatment also upregulated the gene expression levels of lepR, AMP-activated protein kinase (AMPK), acetyl CoA carboxylase-2 (ACC2), and uncoupling protein 3 (UCP3) in liver, abdominal fat, and breast muscle (P < 0.05) but decreased fasn expression levels (P < 0.01). Apart from that of lepR, the expression of appetite-regulating genes, such as orexigenic genes, agouti-related peptide (AgRP) and neuropeptide Y (NPY), were upregulated (P < 0.01), whereas the anorexigenic gene proopiomelanocortin (POMC) was downregulated in the hypothalamic tissue of cLEPR-immunized pullets (P < 0.01). Blood concentrations of metabolic molecules, such as glucose, triglycerides, and very-low-density lipoprotein, were significantly decreased in cLEPR-immunized pullets but those of cholesterol, high-density lipoprotein, and low-density lipoprotein increased. These results demonstrate that antibodies to membrane proximal cLEPR ECD enhance cLEPR signal transduction, which stimulates metabolism and reduces fat deposition in chickens. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Influence of metallic artifact filtering on MEG signals for source localization during interictal epileptiform activity

    NASA Astrophysics Data System (ADS)

    Migliorelli, Carolina; Alonso, Joan F.; Romero, Sergio; Mañanas, Miguel A.; Nowak, Rafał; Russi, Antonio

    2016-04-01

    Objective. Medical intractable epilepsy is a common condition that affects 40% of epileptic patients that generally have to undergo resective surgery. Magnetoencephalography (MEG) has been increasingly used to identify the epileptogenic foci through equivalent current dipole (ECD) modeling, one of the most accepted methods to obtain an accurate localization of interictal epileptiform discharges (IEDs). Modeling requires that MEG signals are adequately preprocessed to reduce interferences, a task that has been greatly improved by the use of blind source separation (BSS) methods. MEG recordings are highly sensitive to metallic interferences originated inside the head by implanted intracranial electrodes, dental prosthesis, etc and also coming from external sources such as pacemakers or vagal stimulators. To reduce these artifacts, a BSS-based fully automatic procedure was recently developed and validated, showing an effective reduction of metallic artifacts in simulated and real signals (Migliorelli et al 2015 J. Neural Eng. 12 046001). The main objective of this study was to evaluate its effects in the detection of IEDs and ECD modeling of patients with focal epilepsy and metallic interference. Approach. A comparison between the resulting positions of ECDs was performed: without removing metallic interference; rejecting only channels with large metallic artifacts; and after BSS-based reduction. Measures of dispersion and distance of ECDs were defined to analyze the results. Main results. The relationship between the artifact-to-signal ratio and ECD fitting showed that higher values of metallic interference produced highly scattered dipoles. Results revealed a significant reduction on dispersion using the BSS-based reduction procedure, yielding feasible locations of ECDs in contrast to the other two approaches. Significance. The automatic BSS-based method can be applied to MEG datasets affected by metallic artifacts as a processing step to improve the localization of epileptic foci.

  8. Pesticide and plasticizer residues in bergamot essential oils from Calabria (Italy).

    PubMed

    Di Bella, Giuseppa; Saitta, Marcello; La Pera, Lara; Alfa, Maria; Dugo, Giacomo

    2004-08-01

    Organophosphorus and organochlorine pesticides, phosphorated plasticizers, chloroparaffins and phthalate esters contamination in bergamot essential oils produced in Calabria in the crop years 1999-2000 was studied by HRGC in connection with detectors FPD, ECD, MS. Residues of dicofol and tetradifon were found in oils from both crop years. The mean dicofol concentration was 0.26 mg/l in samples from 1999 and 0.20 mg/l in those from 2000; the mean tetradifon content was 0.06 mg/l for both the crop years. Among plasticizers, residues of diisobutyl phthalate, di-n-butyl phthalate, and bis(2-ethylhexyl) phthalate were found in samples from crop years 1999 and 2000, the mean content were 1.22 and 1.23 mg/l, 1.51 and 1.65 mg/l, 1.38 and 1.42 mg/l respectively.

  9. ELECTROCHEMICAL DECHLORINATION OF TRICHLOROETHYLENE USING GRANULAR-GRAPHITE ELECTRODES: IDENTIFICATION AND QUANTIFICATION OF DECHLORINATION PRODUCTS

    EPA Science Inventory

    Electrochemical degradation (ECD) utilizes high redox potential at the anode and low redox potential at the cathode to oxidize and/or reduce organic and inorganic contaminants. ECD of Trichloroethylene (TCE), although theoretically possible, has not been experimentally proven. Th...

  10. Conformational states of the full-length glucagon receptor

    PubMed Central

    Yang, Linlin; Yang, Dehua; de Graaf, Chris; Moeller, Arne; West, Graham M.; Dharmarajan, Venkatasubramanian; Wang, Chong; Siu, Fai Y.; Song, Gaojie; Reedtz-Runge, Steffen; Pascal, Bruce D.; Wu, Beili; Potter, Clinton S.; Zhou, Hu; Griffin, Patrick R.; Carragher, Bridget; Yang, Huaiyu; Wang, Ming-Wei; Stevens, Raymond C.; Jiang, Hualiang

    2015-01-01

    Class B G protein-coupled receptors are composed of an extracellular domain (ECD) and a seven-transmembrane (7TM) domain, and their signalling is regulated by peptide hormones. Using a hybrid structural biology approach together with the ECD and 7TM domain crystal structures of the glucagon receptor (GCGR), we examine the relationship between full-length receptor conformation and peptide ligand binding. Molecular dynamics (MD) and disulfide crosslinking studies suggest that apo-GCGR can adopt both an open and closed conformation associated with extensive contacts between the ECD and 7TM domain. The electron microscopy (EM) map of the full-length GCGR shows how a monoclonal antibody stabilizes the ECD and 7TM domain in an elongated conformation. Hydrogen/deuterium exchange (HDX) studies and MD simulations indicate that an open conformation is also stabilized by peptide ligand binding. The combined studies reveal the open/closed states of GCGR and suggest that glucagon binds to GCGR by a conformational selection mechanism. PMID:26227798

  11. Comparisons among Health Behavior Surveys: Implications for the Design of Informatics Infrastructures That Support Comparative Effectiveness Research.

    PubMed

    Yoon, Sunmoo; Wilcox, Adam B; Bakken, Suzanne

    2013-01-01

    To address the electronic health data fragmentation that is a methodological limitation of comparative effectiveness research (CER), the Washington Heights Inwood Informatics Infrastructure for Comparative Effectiveness Research (WICER) project is creating a patient-centered research data warehouse (RDW) by linking electronic clinical data (ECD) from New York Presbyterian Hospital's clinical data warehouse with ECD from ambulatory care, long-term care, and home health settings and the WICER community health survey (CHS). The purposes of the research were to identify areas of overlap between the WICER CHS and two other surveys that include health behavior data (the Behavioral Risk Factor Surveillance System (BRFSS) Survey and the New York City Community Health Survey (NYC CHS)) and to identify gaps in the current WICER RDW that have the potential to affect patient-centered CER. We compared items across the three surveys at the item and conceptual levels. We also compared WICER RDW (ECD and WICER CHS), BRFSS, and NYC CHS to the County Health Ranking framework. We found that 22 percent of WICER items were exact matches with BRFSS and that there were no exact matches between WICER CHS and NYC CHS items not also contained in BRFSS. The results suggest that BRFSS and, to a lesser extent, NYC CHS have the potential to serve as population comparisons for WICER CHS for some health behavior-related data and thus may be particularly useful for considering the generalizability of CER study findings. Except for one measure related to health behavior (motor vehicle crash deaths), the WICER RDW's comprehensive coverage supports the mortality, morbidity, and clinical care measures specified in the County Health Ranking framework but is deficient in terms of some socioeconomic factors and descriptions of the physical environment as captured in BRFSS. Linkage of these data in the WICER RDW through geocoding can potentially facilitate patient-centered CER that integrates important socioeconomic and physical environment influences on health outcomes. The research methods and findings may be relevant to others interested in either integrating health behavior data into RDWs to support patient-centered CER or conducting population-level comparisons.

  12. Determination of benazolin-ethyl residues in soil and rape seed by SPE clean-up and GC with electron capture detection.

    PubMed

    Liu, Xiaolu; Yang, Tao; Hu, Jiye

    2013-01-01

    A method has been developed and established for residue determination of benazolin-ethyl in soil and rape seed samples by gas chromatography with electron capture detection (GC-ECD). Limits of quantification of the method are 0.005 mg/kg for both soil and rape seed, which are sufficiently below the maximum residue limit, and the limit of detection is 0.0023 ng. The average recoveries of the analyte range from 85.89 to 105.84% with relative standard deviations (coefficient of variation) less than 5.53% at the three spike levels (0.005, 0.1 and 0.5 mg/kg). The half-life of benazolin-ethyl in soil from the experimental field is 4.62 days. The final residues of benazolin-ethyl in soil and rape seed samples are lower than 0.005 mg/kg at harvest time. Direct confirmation of the analyte in real samples is achieved by GC-mass spectrometry. It is demonstrated that the proposed method is simple, rapid and efficient, and reliable to detect benazolin-ethyl residues in soil and rape seed samples.

  13. The role of corneal endothelial morphology in graft assessment and prediction of endothelial cell loss during organ culture of human donor corneas.

    PubMed

    Hermel, Martin; Salla, Sabine; Fuest, Matthias; Walter, Peter

    2017-03-01

    Endothelial assessment is crucial in the release of corneas for grafting. We retrospectively analysed the role of endothelial morphology parameters in predicting endothelial cell loss during organ culture. Human donor corneas were cultured in minimal essential medium with 2% fetal calf serum and antibiotics. Initial endothelial morphology was assessed microscopically using score parameters polymegethism (POL), pleomorphism (PLE), granulation (GRA), vacuolization (VAC), segmentation of cell membranes (SEG), Descemet's folds (DF), trypan blue-positive cells (TBPC) and endothelial cell-free areas (ECFA). Some corneas were primarily rejected based on endothelial assessment. Endothelial cell density (ECD) was assessed at the beginning (I-ECD) and end of culture. Corneas were then placed in dehydration medium (as above + 5% dextran 500). In a subgroup, ECD was reassessed after dehydration. Endothelial cell loss during culture (ECL@Culture) and culture+dehydration (ECL-Culture&Dehydration) were calculated. Data were given as mean ± SD and analysed using multiple linear and logistic regression. Odds ratios (OR) and 95% confidence intervals (CI) were calculated. I-ECD was 2812 ± 360/mm 2 (n = 2356). The decision to reject a cornea due to endothelial assessment was associated negatively with I-ECD (OR = 0.77/100 cells, CI 0.7-0.82) and positively with ECFA (OR = 2.7, CI 1.69-4.35), SEG (OR =1.3, CI 1.01-1.68) and donor age (OR = 1.26/decade, CI 1.33-1.41). ECL@Culture was 153 ± 201/mm 2 (n = 1277), ECL@Culture&Dehydration was 169 ± 183/mm 2 (n = 918). ECL@Culture was associated positively with donor age, I-ECD, GRA and TBPC, and negatively with PLE, and DF. ECL@Culture&Dehydration was associated positively with age, sex, initial ECD, POL, PLE, VAC and TBPC. Morphological parameters displayed associations with the exclusion of corneas from culture and with endothelial cell loss. Appropriate parameter selection for screening purposes may help improve graft quality. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  14. Structural and functional characterizations of activin type 2B receptor (acvr2b) ortholog from the marine fish, gilthead sea bream, Sparus aurata: evidence for gene duplication of acvr2b in fish.

    PubMed

    Funkenstein, Bruria; Krol, Ekaterina; Esterin, Elena; Kim, Yong-Soo

    2012-12-01

    Myostatin (MSTN), a negative regulator of muscle growth and a member of the transforming growth factor-β superfamily, can bind the two activin type 2 receptors (ACVR2). It has been previously shown that WT mice injected with ACVR2B extracellular domain (ACVR2B-ECD) had higher muscle mass. Likewise, fish larvae immersed in Pichia pastoris culture supernatant, containing goldfish Acvr2b-ECD, showed enhanced larval growth. However, it is not clear whether fish Mstn1 and Mstn2 signal through the same receptor and whether fish express more than one acvr2b gene. In the current study, three cDNAs encoding acvr2b (saacvr2b-1, saacvr2b-2a, and saacvr2b-2b) were cloned from gilthead sea bream. All three contain the short extracellular binding domain, a short transmembrane region, and a conserved catalytic domain of serine/threonine protein kinase. Bioinformatics analysis provided evidence for the existence of two acvr2b genes (acvr2b-1 and acvr2b-2) in several other fish species as well, probably as a result of gene or genome duplication. The two isoforms differ in their amino acid sequences. The direct inhibitory effect of Acvr2b-ECD on Mstn activity was tested in vitro. The saAcvr2b-1-ECD was expressed in the yeast P. pastoris. Evidence is provided for N-glycosylation of Acvr2b-1-ECD. The affinity-purified Acvr2b-1-ECD inhibited recombinant mouse/rat/human mature MSTN activity when determined in vitro using the CAGA-luciferase assay in A204 cells. A lower inhibitory activity was obtained when unprocessed purified, furin-digested, and activated saMstn1 was used. Results of this study demonstrate for the first time the existence of two acvr2b genes in fish. In addition, the study shows that bioactive fish Acvr2b-ECD can be produced from P. pastoris.

  15. Assignment of absolute stereostructures through quantum mechanics electronic and vibrational circular dichroism calculations.

    PubMed

    Dai, Peng; Jiang, Nan; Tan, Ren-Xiang

    2016-01-01

    Elucidation of absolute configuration of chiral molecules including structurally complex natural products remains a challenging problem in organic chemistry. A reliable method for assigning the absolute stereostructure is to combine the experimental circular dichroism (CD) techniques such as electronic and vibrational CD (ECD and VCD), with quantum mechanics (QM) ECD and VCD calculations. The traditional QM methods as well as their continuing developments make them more applicable with accuracy. Taking some chiral natural products with diverse conformations as examples, this review describes the basic concepts and new developments of QM approaches for ECD and VCD calculations in solution and solid states.

  16. Implications of Evidence-Centered Design for Educational Testing

    ERIC Educational Resources Information Center

    Mislevy, Robert J.; Haertel, Geneva D.

    2006-01-01

    Evidence-centered assessment design (ECD) provides language, concepts, and knowledge representations for designing and delivering educational assessments, all organized around the evidentiary argument an assessment is meant to embody. This article describes ECD in terms of layers for analyzing domains, laying out arguments, creating schemas for…

  17. MEASUREMENT OF DIBROMOACETIC ACID IN RAT BLOOD BY GC/ECD

    EPA Science Inventory

    Measurement of Dibromoacetic Acid in Rat Blood by GC/ECD

    M. Leonard Mole, MD 67, Reproductive Toxicology Division, National Health and Environmental Effects Research Laboratory, USEPA, Research Triangle Park, NC 27711; Phone: 919-541-2680, FAX: 919-541-4017, e-mail: mole.l...

  18. Development of a thin scintillation films fission-fragment detector and a novel neutron source

    DOE PAGES

    Rusev, Gencho Yordanov; Jandel, Marian; Baramsai, Bayarbadrakh; ...

    2015-08-26

    Here, investigation of prompt fission and neutron-capture Υ rays from fissile actinide samples at the Detector for Advanced Neutron Capture Experiments (DANCE) requires use of a fission-fragment detector to provide a trigger or a veto signal. A fission-fragment detector based on thin scintillating films and silicon photomultipliers has been built to serve as a trigger/veto detector in neutron-induced fission measurements at DANCE. The fissile material is surrounded by scintillating films providing a 4π detection of the fission fragments. The scintillations were registered with silicon photomultipliers. A measurement of the 235U(n,f) reaction with this detector at DANCE revealed a correct time-of-flightmore » spectrum and provided an estimate for the efficiency of the prototype detector of 11.6(7)%. Design and test measurements with the detector are described. A neutron source with fast timing has been built to help with detector-response measurements. The source is based on the neutron emission from the spontaneous fission of 252Cf and the same type of scintillating films and silicon photomultipliers. Overall time resolution of the source is 0.3 ns. Design of the source and test measurements with it are described. An example application of the source for determining the neutron/gamma pulse-shape discrimination by a stilbene crystal is given.« less

  19. Detector for imaging and dosimetry of laser-driven epithermal neutrons by alpha conversion

    NASA Astrophysics Data System (ADS)

    Mirfayzi, S. R.; Alejo, A.; Ahmed, H.; Wilson, L. A.; Ansell, S.; Armstrong, C.; Butler, N. M. H.; Clarke, R. J.; Higginson, A.; Notley, M.; Raspino, D.; Rusby, D. R.; Borghesi, M.; Rhodes, N. J.; McKenna, P.; Neely, D.; Brenner, C. M.; Kar, S.

    2016-10-01

    An epithermal neutron imager based on detecting alpha particles created via boron neutron capture mechanism is discussed. The diagnostic mainly consists of a mm thick Boron Nitride (BN) sheet (as an alpha converter) in contact with a non-borated cellulose nitride film (LR115 type-II) detector. While the BN absorbs the neutrons in the thermal and epithermal ranges, the fast neutrons register insignificantly on the detector due to their low neutron capture and recoil cross-sections. The use of solid-state nuclear track detectors (SSNTD), unlike image plates, micro-channel plates and scintillators, provide safeguard from the x-rays, gamma-rays and electrons. The diagnostic was tested on a proof-of-principle basis, in front of a laser driven source of moderated neutrons, which suggests the potential of using this diagnostic (BN+SSNTD) for dosimetry and imaging applications.

  20. Directional Antineutrino Detection

    NASA Astrophysics Data System (ADS)

    Safdi, B. R.; Suerfu, J.

    2014-12-01

    We propose the first truly directional antineutrino detector for antineutrinos near the threshold for the inverse beta decay (IBD) of hydrogen, with potential applications including the spatial mapping of geo-neutrinos, searches for stellar antineutrinos, and the monitoring of nuclear reactors. The detector consists of adjacent and separated target and neutron-capture layers. The IBD events, which result in a neutron and a positron, take place in the target layers. These layers are thin enough so that the neutrons escape without scattering elastically. The neutrons are detected in the thicker neutron-capture layers. The location of the IBD event is determined from the energy deposited by the positron as it slows in the medium and from the two gamma rays that come from the positron annihilation. Since the neutron recoils in the direction of the antineutrino's motion, a line may then be drawn between the IBD event location and the neutron-capture location to approximate the antineutrino's velocity. In some events, we may even measure the positron's velocity, which further increases our ability to reconstruct the antineutrino's direction of motion. Our method significantly improves upon previous methods by allowing the neutron to freely travel a long distance before diffusing and being captured. Moreover, our design is a straightforward modification of existing antineutrino detectors; a prototype could easily be built with existing technology. We verify our design through Monte Carlo simulations in Geant4, using commercially-available boron-loaded plastic scintillators for the target and neutron-capture layer materials. We are able to discriminate from background using multiple coincidence signatures within a short, ~microsecond time interval. We conclude that the detector could likely operate above ground with minimal shielding.

  1. Precut cornea for Descemet's stripping endothelial keratoplasty: experience at a single eye bank.

    PubMed

    Mohamed, Ashik; Chaurasia, Sunita; Chandragiri, Venkataswamy; Kandhibanda, Srinivas; Gunnam, Srinivas; Garg, Prashant

    2017-06-01

    The aim of the study is to describe the experience with precut facility for endothelial keratoplasty at a single eye bank affiliated to a tertiary eye care center in India. Data on precut tissues from Nov 2012 to Dec 2014 were retrospectively reviewed from the electronic database of the eye bank of a tertiary eye care center in South India. Donor characteristic data including donor age, precut and postcut endothelial cell density (ECD), recipient age, and thickness of graft were collected. The number of precuts increased from 42 in 2012 (Nov and Dec) and 422 in 2013 to 584 in 2014. Of the total of 1048 precuts, seven (0.67 %) were miscut and could not be utilized for transplants. The donor age ranged from 2 to 89 years. A mean change of 43.6 ± 325.2 cells/mm 2 in ECD was noted after cut, proportional increase in mean being 1.9 %. The change in ECD after cut was negatively correlated with ECD before cut. The recipient age ranged from 1 to 89 years. The median thickness of donor lenticule after cut was 148 µm (interquartile range 131-166 µm). Analysis of precut donor corneas from a single eye bank shows that the ECD of the processed tissues was excellent for transplantation. The tissue wastage in the hands of eye bank personal was minimal.

  2. Effect of Range and Angular Velocity of Passive Movement on Somatosensory Evoked Magnetic Fields.

    PubMed

    Sugawara, Kazuhiro; Onishi, Hideaki; Yamashiro, Koya; Kojima, Sho; Miyaguchi, Shota; Kotan, Shinichi; Tsubaki, Atsuhiro; Kirimoto, Hikari; Tamaki, Hiroyuki; Shirozu, Hiroshi; Kameyama, Shigeki

    2016-09-01

    To clarify characteristics of each human somatosensory evoked field (SEF) component following passive movement (PM), PM1, PM2, and PM3, using high spatiotemporal resolution 306-channel magnetoencephalography and varying PM range and angular velocity. We recorded SEFs following PM under three conditions [normal range-normal velocity (NN), small range-normal velocity (SN), and small range-slow velocity (SS)] with changing movement range and angular velocity in 12 participants and calculated the amplitude, equivalent current dipole (ECD) location, and the ECD strength for each component. All components were observed in six participants, whereas only PM1 and PM3 in the other six. Clear response deflections at the ipsilateral hemisphere to PM side were observed in seven participants. PM1 amplitude was larger under NN and SN conditions, and mean ECD location for PM1 was at primary motor area. PM3 amplitude was larger under SN condition and mean ECD location for PM3 under SS condition was at primary somatosensory area. PM1 amplitude was dependent on the angular velocity of PM, suggesting that PM1 reflects afferent input from muscle spindle, whereas PM3 amplitude was dependent on the duration. The ECD for PM3 was located in the primary somatosensory cortex, suggesting that PM3 reflects cutaneous input. We confirmed the hypothesis for locally distinct generators and characteristics of each SEF component.

  3. Viral transduction of the HER2-extracellular domain expands trastuzumab-based photoimmunotherapy for HER2-negative breast cancer cells.

    PubMed

    Shimoyama, Kyoko; Kagawa, Shunsuke; Ishida, Michihiro; Watanabe, Shinichiro; Noma, Kazuhiro; Takehara, Kiyoto; Tazawa, Hiroshi; Hashimoto, Yuuri; Tanabe, Shunsuke; Matsuoka, Junji; Kobayashi, Hisataka; Fujiwara, Toshiyoshi

    2015-02-01

    The prognosis of HER2-positive breast cancer has been improved by trastuzumab therapy, which features high specificity and limited side effects. However, trastuzumab-based therapy has shortcomings. Firstly, HER2-targeted therapy is only applicable to HER2-expressing tumors, which comprise only 20-25% of primary breast cancers. Secondly, many patients who initially respond to trastuzumab ultimately develop disease progression. To overcome these problems, we employed virus-mediated HER2 transduction and photoimmunotherapy (PIT) which involves trastuzumab conjugated with a photosensitizer, trastuzumab-IR700, and irradiation of near-infrared light. We hypothesized that the gene transduction technique together with PIT would expand the range of tumor entities suitable for trastuzumab-based therapy and improve its antitumor activity. The HER2-extracellular domain (ECD) was transduced by the adenoviral vector, Ad-HER2-ECD, and PIT with trastuzumab-IR700 was applied in the HER2-negative cancer cells. Ad-HER2-ECD can efficiently transduce HER2-ECD into HER2-negative human cancer cells. PIT with trastuzumab-IR700 induced direct cell membrane destruction of Ad-HER2-ECD-transduced HER2-negative cancer cells. Novel combination of viral transduction of a target antigen and an antibody-based PIT would expand and potentiate molecular-targeted therapy even for target-negative or attenuated cancer cells.

  4. Acute Effects of an Alternative Electronic-Control-Device Waveform in Swine

    DTIC Science & Technology

    2009-03-01

    sequences in a normal individual. Bozeman [32] suggested that lethality due to ECD impact could be due to hyperkalemia related to muscle contraction...and our previous investigations [1, 2], there may be a wide margin of safety, relative to hyperkalemia , for most ECD applications. The increase in

  5. Assessment Of The Functionality Of A Pilot-Scale Reactor And Its Potential For Electrochemical Degradation Of Calmagite, A Sulfonated Azo-Dye

    EPA Science Inventory

    Electrochemical degradation (ECD) is a promising technology for in situ remediation of diversely contaminated environmental matrices by application of a low level electric potential gradient. This investigation, prompted by successful bench-scale ECD of trichloroethylene,...

  6. A novel cardanol-based antioxidant and its application in vegetable oils and biodiesel

    USDA-ARS?s Scientific Manuscript database

    A novel antioxidant, epoxidized cardanol (ECD), derived from cardanol has been synthesized and characterized by FT-IR, 1H-NMR and 13C-NMR. Oxidative stability of ECD in vegetable oils and biodiesel was evaluated by the pressurized differential scanning calorimetry and Rancimat methods, respectively....

  7. Synthesis of epoxidized cardanol and its antioxidative properties for vegetable oils and biodiesel

    USDA-ARS?s Scientific Manuscript database

    A novel antioxidant epoxidized cardanol (ECD), derived from cardanol, was synthesized and characterized by FT-IR, 1H-NMR and 13C-NMR. Oxidative stability of ECD used in vegetable oils and biodiesel was evaluated by pressurized differential scanning calorimetry (PDSC) and the Rancimat method, respect...

  8. Design and Discovery in Educational Assessment: Evidence-Centered Design, Psychometrics, and Educational Data Mining

    ERIC Educational Resources Information Center

    Mislevy, Robert J.; Behrens, John T.; Dicerbo, Kristen E.; Levy, Roy

    2012-01-01

    "Evidence-centered design" (ECD) is a comprehensive framework for describing the conceptual, computational and inferential elements of educational assessment. It emphasizes the importance of articulating inferences one wants to make and the evidence needed to support those inferences. At first blush, ECD and "educational data…

  9. 78 FR 67020 - Airworthiness Directives; Eurocopter Deutschland GmbH (ECD) Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-08

    ... Airworthiness Directives; Eurocopter Deutschland GmbH (ECD) Helicopters AGENCY: Federal Aviation Administration... the AD Docket at http://www.regulations.gov . (h) Subject Joint Aircraft Service Component (JASC) Code..., of Eurocopter Deutschland GmbH Flight Manual BO 105 C/CS, Revision 5, dated March 12, 2010. (ii...

  10. An overview of DANCE: a 4II BaF[2] detector for neutron capture measurements at LANSCE.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ullmann, J. L.

    2004-01-01

    The Detector for Advanced Neutron Capture experiments (DANCE) is a 162-element, 4{pi} BaF{sub 2} array designed to make neutron capture cross-section measurements on rare or radioactive targets with masses as little as 1 mg. Accurate capture cross sections are needed in many research areas, including stellar nucleosynthesis, advanced nuclear fuel cycles, waste transmutation, and other applied programs. These cross sections are difficult to calculate accurately and must be measured. Up to now, except for a few long-lived nuclides there are essentially no differential capture measurements on radioactive nuclei. The DANCE array is located at the Lujan Neutron Scattering Center atmore » LANSCE, which is a continuous-spectrum neutron source with useable energies from below thermal to about 100 keV. Data acquisition is done with 320 fast waveform digitizers. The design and initial performance results, including background minimization, will be discussed.« less

  11. NON-INVASIVE DETERMINATION OF THE LOCATION AND DISTRIBUTION OF FREE-PHASE DENSE NONAQUEOUS PHASE LIQUIDS (DNAPL) BY SEISMIC REFLECTION TECHNIQUES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michael G. Waddell; William J. Domoracki; Tom J. Temples

    2001-12-01

    This annual technical progress report is for part of Task 4 (site evaluation), Task 5 (2D seismic design, acquisition, and processing), and Task 6 (2D seismic reflection, interpretation, and AVO analysis) on DOE contact number DE-AR26-98FT40369. The project had planned one additional deployment to another site other than Savannah River Site (SRS) or DOE Hanford Site. After the SUBCON midyear review in Albuquerque, NM, it was decided that two additional deployments would be performed. The first deployment is to test the feasibility of using non-invasive seismic reflection and AVO analysis as a monitoring tool to assist in determining the effectivenessmore » of Dynamic Underground Stripping (DUS) in removal of DNAPL. The second deployment is to the Department of Defense (DOD) Charleston Naval Weapons Station Solid Waste Management Unit 12 (SWMU-12), Charleston, SC to further test the technique to detect high concentrations of DNAPL. The Charleston Naval Weapons Station SWMU-12 site was selected in consultation with National Energy Technology Laboratory (NETL) and DOD Naval Facilities Engineering Command Southern Division (NAVFAC) personnel. Based upon the review of existing data and due to the shallow target depth, the project team collected three Vertical Seismic Profiles (VSP) and an experimental P-wave seismic reflection line. After preliminary data analysis of the VSP data and the experimental reflection line data, it was decided to proceed with Task 5 and Task 6. Three high resolution P-wave reflection profiles were collected with two objectives; (1) design the reflection survey to image a target depth of 20 feet below land surface to assist in determining the geologic controls on the DNAPL plume geometry, and (2) apply AVO analysis to the seismic data to locate the zone of high concentration of DNAPL. Based upon the results of the data processing and interpretation of the seismic data, the project team was able to map the channel that is controlling the DNAPL plume geometry. The AVO analysis located a major amplitude anomaly, which was tested using a Geoprobe{trademark} direct push system. The Geoprobe{trademark} was equipped with a membrane interface probe (MIP) that was interfaced with a sorbent trap/gas chromatograph (GC) system. Both the Photo Ionization Detector (PID) and Electron Capture Detector (ECD) on the GC exceeded the maximum measurement values through the anomaly. A well was installed to collect a water sample. The concentration of chlorinated solvents in the water sample was in excess of 500 ppm. Other amplitude anomalies located directly under an asphalt road were also tested. Both the PID and ECD were zero. It appears that editing of poor quality near-offset traces during data processing caused these anomalies. Not having the full range of source to receiver offset traces in those areas resulted in a false anomaly during AVO analysis. This phenomenon was also observed at the beginning and end of each seismic profile also for the same reason. Based upon the water samples and MIP probes, it appears that surface seismic and AVO analysis were able to detect the area of highest concentration of DNAPL.« less

  12. Design and development of a Gadolinium-doped water Cherenkov detector

    NASA Astrophysics Data System (ADS)

    Poudyal, Nabin

    This thesis describes a research and development project for neutron capture and detection in Gadolinium doped water. The Sanford Underground Research Facility (SURF) is exploring rare event physics, such as neutrinoless double beta decay (MAJORANA Project) and dark-matter detection (LUX experiment). The success of these experiments requires a careful study and understanding of background radiation, including flux and energy spectrum. The background radiation from surface contamination, radioactive decays of U-238, Th-232, Rn-222 in the surrounding rocks and muon induced neutrons have a large impact on the success of rare-event physics. The main objective of this R&D project is to measure the neutron flux contributing to ongoing experiments at SURF and suppress it by identification and capture method. For this purpose, we first modeled and designed a detector with Geant4 software. The approximate dimension of the detector is determined. The neutron capture percentage of the detector is estimated using Monte Carlo. The energy response of the detector is simulated. Next, we constructed the experimental detector, an acrylic rectangular tank (60cm x 30cm x 30cm), filled with Gadolinium-doped deionized water. The tank is coated with high efficient reflector and then taped with black electrical tape to make it opaque. The voltage dividers attached to PMTs are covered with mu-metal. Two 5-inch Hamamatsu Photomultiplier tubes were attached on both sides facing the tank to collect the Cherenkov light produced in the water. The detector utilizes the principle of Cherenkov light emission by a charged particle moving through a water at a speed higher than the speed of light in the water, hence it has an inherent energy threshold of Cherenkov photon production. This property reduces the lower energy backgrounds. Event data are obtained using the Data Acquisition hardware, Flash Analog to digital converter, along with Multi Instance Data Acquisition software. Post-experimental analysis was performed using ROOT software. Position calibration of the detector shows that the detector is position independent. We have designed and constructed the Gd-doped neutron detector which successfully detects the neutrons with low cost and high efficiency.

  13. Development of an Electron-capture Technique Specific for Explosives Detection

    DOT National Transportation Integrated Search

    1974-07-01

    This document contains information on the design, fabrication, and testing of a prototype detector specific for explosives which employs electron-capture sensors. The technique used exploits the observation that the electronegative vapors from explos...

  14. Unifying measurement of Pu 239 ( n , γ ) in the keV to MeV energy regime

    DOE PAGES

    Mosby, S.; Bredeweg, T. A.; Couture, A.; ...

    2018-04-23

    A single, unifying measurement of the 239Pu capture cross section from 1 keV to 1.3 MeV has been performed for the first time using the Detector for Advanced Neutron Capture Experiments (DANCE) at the Los Alamos Neutron Science Center (LANSCE). The experimental method combines a prior experiment's characterization of prompt fission γ rays in conjunction with a fission tagging detector with a separate experiment using a thick 239Pu sample to extract the neutron capture cross section in ratio to 239Pu (n, f). We have made new predictions of the capture cross section taking into account recent results for the M1more » scissors mode present in other actinides. The results show deviations from current evaluations which are 30% higher at the highest energies, and will be used to improve calculations relevant for several applications.« less

  15. Unifying measurement of 239Pu(n ,γ ) in the keV to MeV energy regime

    NASA Astrophysics Data System (ADS)

    Mosby, S.; Bredeweg, T. A.; Couture, A.; Jandel, M.; Kawano, T.; Ullmann, J. L.; Henderson, R. A.; Wu, C. Y.

    2018-04-01

    A single, unifying measurement of the 239Pu capture cross section from 1 keV to 1.3 MeV has been performed for the first time using the Detector for Advanced Neutron Capture Experiments (DANCE) at the Los Alamos Neutron Science Center (LANSCE). The experimental method combines a prior experiment's characterization of prompt fission γ rays in conjunction with a fission tagging detector with a separate experiment using a thick 239Pu sample to extract the neutron capture cross section in ratio to 239Pu(n ,f ) . We have made new predictions of the capture cross section taking into account recent results for the M 1 scissors mode present in other actinides. The results show deviations from current evaluations which are 30% higher at the highest energies, and will be used to improve calculations relevant for several applications.

  16. Comparison of technetium-99m-HMPAO and technetium-99m-ECD cerebral SPECT images in Alzheimer`s disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dyck, C.H. van; Lin, C.H.; Smith, E.O.

    1996-11-01

    SPECT has shown increasing promise as a diagnostic tool in Alzheimer`s disease (AD). Recently, a new SPECT brain perfusion agent, {sup 99m}Tc-ethyl cysteinate dimer ({sup 99m}Tc-ECD) has emerged with purported advantages in image quality over the established tracer, {sup 99m}Tc-hexamethylpropyleneamine oxime ({sup 99m}Tc-HMPAO). This research aimed to compare cerebral images for ({sup 99m}Tc-HMPAO). This research aimed to compare cerebral images for {sup 99}mTc-HMPAO and {sup 99m}Tc-ECD in discriminating patients with AD form control subjects. 51 refs., 5 figs., 3 tabs.

  17. EXOGAM at the ILL: the EXILL campaign

    NASA Astrophysics Data System (ADS)

    de France, G.; Blanc, A.; Drouet, F.; Jentschel, M.; Köster, U.; Mutti, P.; Régis, J. M.; Simpson, G.; Soldner, T.; Stezowski, O.; Ur, C. A.; Urban, W.; Vancrayenest, A.

    2018-02-01

    A combination of germanium detectors has been installed at the PF1B neutron guide of the ILL to perform the prompt spectroscopy of neutron-rich nuclei produced in the neutron-capture induced-fission of 235U and 241Pu. Radiative capture reactions on rare targets have also been performed. LaBr3 detectors from the FATIMA collaboration have also been installed in complement with the EXOGAM clovers to measure lifetimes of low-lying excited states. The measured characteristics indicate very good performances of the overall setup. Some recent results will be discussed.

  18. EXOGAM at the ILL: the EXILL campaign

    NASA Astrophysics Data System (ADS)

    de France, Gilles; Blanc, Aurélien; Jentschel, Michael; Köster, Ulli; Leoni, Silvia; Mutti, Paolo; Simpson, Gary; Soldner, Torsten; Urban, Waldemar

    2018-05-01

    Radiative capture reactions on rare targets and prompt spectroscopy of neutron-rich nuclei produced in the neutron-capture induced-fission of 235U and 241Pu have been performed at the Institut Laue-Langevin (ILL). The high efficiency germanium (Ge) EXOGAM array has been used, complemented with Ge detectors from GASP and the ILL. LaBr3 detectors from the FATIMA collaboration have also been coupled to EXOGAM to measure lifetimes of lowlying excited states. The measured characteristics indicate very good performances of the overall setup. Some recent results will be discussed.

  19. Possible Detection of Solar Neutrons from the ISS

    NASA Astrophysics Data System (ADS)

    Benker, Nicole; Echeverria-Mora, Elena; Hamblin, Jennifer; Dowben, Peter A.; Enders, Axel; Kananen, Brant; Petrosky, James; McClory, John

    2018-06-01

    A low energy steady state solar neutron flux has been long predicted [1]. The Detector for the Analysis of Solar Neutrons (DANSON), designed to detect this flux, was launched on the OA-5 mission to the International Space Station (ISS) on 17 Oct. 2016, deployed aboard ISS, and returned 19 March 2017. This detector is insensitive to high energy solar neutron events associated with solar flares, which have now been routinely detected in the range of 40 to 140 MeV, but the lower energy steady state solar neutron background has not been thoroughly examined. DANSON is based on boron rich detector elements combined with a plastic moderator to thermalize neutrons at energies above 40 meV, maximizing the B10 capture of epithermal neutrons. The detector elements include boron carbide (B10C2HX) heterojunction diodes on silicon and lithium tetraborate (Li2B4O7) single crystals. Three types of lithium tetraborate detector elements are used: crystals with a natural abundance of 10B (approx. 20% 10B, 80% 11B), crystals enriched in 10B, and crystals enriched in 11B. Enrichment in 10B provides a higher cross section for thermal neutron capture, while enrichment in 11B results in a negligible cross section for thermal neutron capture while maintaining a proton capture cross section comparable to that of 10B. The signature of neutron capture in the lithium tetraborate samples is evident in the thermoluminescent spectra. In the boron carbide diodes, the signature is measured in the huge decrease in drift carrier lifetimes compared to pre-flight characterization data, corresponding to about 3×109 neutrons/cm2 exposure. Since the estimated total solar exposure time for deployment is 8×106 seconds, this amounts to about 250 to 375 neutrons and protons/cm2sec. The detector package shows increased detection on the zenith side of ISS, after subtraction of radiation events from energetic protons and other sources, indicating possible detection of solar neutrons. Additionally, detection of events on the nadir side implies detection of cosmic ray generated neutrons.[1] Biermann VL, Haxe O, Schulter A (1951) Neutrale Ultrastrahlung von der Sonne. Zeitschrift für Naturforschung 6a: 47-48.

  20. A high-rate 10B-loaded liquid scintillation detector for parity-violation studies in neutron resonances

    NASA Astrophysics Data System (ADS)

    Yen, Yi-Fen; Bowman, J. D.; Bolton, R. D.; Crawford, B. E.; Delheij, P. P. J.; Hart, G. W.; Haseyama, T.; Frankle, C. M.; Iinuma, M.; Knudson, J. N.; Masaike, A.; Masuda, Y.; Matsuda, Y.; Mitchell, G. E.; Penttilä, S. I.; Roberson, N. R.; Seestrom, S. J.; Sharapov, E.; Shimizu, H. M.; Smith, D. A.; Stephenson, S. L.; Szymanski, J. J.; Yoo, S. H.; Yuan, V. W.

    2000-06-01

    We have developed a large-area 10B-loaded liquid scintillation detector for parity-violation studies in neutron resonances with high instantaneous neutron fluxes from the LANSCE short-pulse spallation source. The detector has an efficiency of 95%, 85% and 71% at neutron energies of 10, 100 and 1000 eV, respectively. The neutron mean capture time in the detector is (416±5) ns. We describe the detector and the current-mode signal processing system, that can handle neutron rates up to 500 MHz.

  1. How Task Features Impact Evidence from Assessments Embedded in Simulations and Games

    ERIC Educational Resources Information Center

    Almond, Russell G.; Kim, Yoon Jeon; Velasquez, Gertrudes; Shute, Valerie J.

    2014-01-01

    One of the key ideas of evidence-centered assessment design (ECD) is that task features can be deliberately manipulated to change the psychometric properties of items. ECD identifies a number of roles that task-feature variables can play, including determining the focus of evidence, guiding form creation, determining item difficulty and…

  2. On Instructional Utility, Statistical Methodology, and the Added Value of ECD: Lessons Learned from the Special Issue

    ERIC Educational Resources Information Center

    Nelson, Brian; Nugent, Rebecca; Rupp, Andre A.

    2012-01-01

    This special issue of "JEDM" was dedicated to bridging work done in the disciplines of "educational and psychological assessment" and "educational data mining" (EDM) via the assessment design and implementation framework of "evidence-centered design" (ECD). It consisted of a series of five papers: one…

  3. Putting ECD into Practice: The Interplay of Theory and Data in Evidence Models within a Digital Learning Environment

    ERIC Educational Resources Information Center

    Rupp, Andre A.; Levy, Roy; Dicerbo, Kristen E.; Sweet, Shauna J.; Crawford, Aaron V.; Calico, Tiago; Benson, Martin; Fay, Derek; Kunze, Katie L.; Mislevy, Robert J.; Behrens, John T.

    2012-01-01

    In this paper we describe the development and refinement of "evidence rules" and "measurement models" within the "evidence model" of the "evidence-centered design" (ECD) framework in the context of the "Packet Tracer" digital learning environment of the "Cisco Networking Academy." Using…

  4. A Brief Introduction to Evidence-Centered Design. CSE Report 632

    ERIC Educational Resources Information Center

    Mislevy, Robert J.; Almond, Russell G.; Lukas, Janice F.

    2004-01-01

    Evidence-centered assessment design (ECD) is an approach to constructing educational assessments in terms of evidentiary arguments. This paper provides an introduction to the basic ideas of ECD, including some of the terminology and models that have been developed to implement the approach. In particular, it presents the high-level models of …

  5. Issues in and Challenges to Professionalism in Africa's Cultural Settings

    ERIC Educational Resources Information Center

    Nsamenang, A. Bame

    2010-01-01

    This article explores critical issues linked to early child development (ECD) professionalism in African childhood contexts in the light of rights-based consideration. Against the backdrop of acculturation being a reality in Africa, it accepts professionalism as a "good thing" for ECD programmes in Africa. The article sketches a portrait…

  6. 40 CFR 141.131 - Analytical requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., respectively. The cited methods published in either edition may be used. Copies may be obtained from the... obtained from the American Society for Testing and Materials International, 100 Barr Harbor Drive, West... 6251 B-94 SPE (acidic methanol)/GC/ECD 552.1 5 LLE (acidic methanol)/GC/ECD 552.2, 552.3 Bromate Ion...

  7. 40 CFR 141.131 - Analytical requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., respectively. The cited methods published in either edition may be used. Copies may be obtained from the... obtained from the American Society for Testing and Materials International, 100 Barr Harbor Drive, West... 6251 B-94 SPE (acidic methanol)/GC/ECD 552.1 5 LLE (acidic methanol)/GC/ECD 552.2, 552.3 Bromate Ion...

  8. Dimeric Arrangement of the Parathyroid Hormone Receptor and a Structural Mechanism for Ligand-induced Dissociation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pioszak, Augen A.; Harikumar, Kaleeckal G.; Parker, Naomi R.

    2010-06-25

    The parathyroid hormone receptor (PTH1R) is a class B G protein-coupled receptor that is activated by parathyroid hormone (PTH) and PTH-related protein (PTHrP). Little is known about the oligomeric state of the receptor and its regulation by hormone. The crystal structure of the ligand-free PTH1R extracellular domain (ECD) reveals an unexpected dimer in which the C-terminal segment of both ECD protomers forms an {alpha}-helix that mimics PTH/PTHrP by occupying the peptide binding groove of the opposing protomer. ECD-mediated oligomerization of intact PTH1R was confirmed in living cells by bioluminescence and fluorescence resonance energy transfer experiments. As predicted by the structure,more » PTH binding disrupted receptor oligomerization. A receptor rendered monomeric by mutations in the ECD retained wild-type PTH binding and cAMP signaling ability. Our results are consistent with the hypothesis that PTH1R forms constitutive dimers that are dissociated by ligand binding and that monomeric PTH1R is capable of activating G protein.« less

  9. Molecular Recognition of Corticotropin releasing Factor by Its G protein-coupled Receptor CRFR1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pioszak, Augen A.; Parker, Naomi R.; Suino-Powell, Kelly

    2009-01-15

    The bimolecular interaction between corticotropin-releasing factor (CRF), a neuropeptide, and its type 1 receptor (CRFR1), a class B G-protein-coupled receptor (GPCR), is crucial for activation of the hypothalamic-pituitary-adrenal axis in response to stress, and has been a target of intense drug design for the treatment of anxiety, depression, and related disorders. As a class B GPCR, CRFR1 contains an N-terminal extracellular domain (ECD) that provides the primary ligand binding determinants. Here we present three crystal structures of the human CRFR1 ECD, one in a ligand-free form and two in distinct CRF-bound states. The CRFR1 ECD adopts the alpha-beta-betaalpha fold observedmore » for other class B GPCR ECDs, but the N-terminal alpha-helix is significantly shorter and does not contact CRF. CRF adopts a continuous alpha-helix that docks in a hydrophobic surface of the ECD that is distinct from the peptide-binding site of other class B GPCRs, thereby providing a basis for the specificity of ligand recognition between CRFR1 and other class B GPCRs. The binding of CRF is accompanied by clamp-like conformational changes of two loops of the receptor that anchor the CRF C terminus, including the C-terminal amide group. These structural studies provide a molecular framework for understanding peptide binding and specificity by the CRF receptors as well as a template for designing potent and selective CRFR1 antagonists for therapeutic applications.« less

  10. The role of nutrition in integrated early child development in the 21st century: contribution from the Maternal and Child Nutrition journal.

    PubMed

    Pérez-Escamilla, Rafael; Moran, Victoria Hall

    2017-01-01

    Even though it is widely recognized that early childhood development (ECD) is one of the most important predictors of future social capital and national productivity, the recently published ECD Lancet Series reports that about 250 million children under 5 years are at risk of not reaching their developmental potential, mainly as a result of poverty and social injustice. So why is this and what will it take to reverse this situation? The purpose of this special issue is to highlight important contributions from previously published articles in Maternal & Child Nutrition to the field of nutrition and ECD. The collection of papers presented in this special issue collectively indicates that although nutrition-specific interventions are essential for child development, they are not sufficient by themselves for children to reach their full developmental potential. This is because ECD is influenced by many other factors besides nutrition, including hand washing/sanitation, parenting skills, psychosocial stimulation, and social protection. Future research should focus on mixed-methods implementation science seeking to understand how best to translate evidence-based integrated ECD packages into effective intersectoral policies and programs on a large scale. In addition to health and nutrition, these programs need to consider and include responsive parenting (including responsive feeding), learning stimulation, education, and social protection. Future studies should also address if and how childhood obesity affects human physical, socioemotional, and cognitive development. © 2016 John Wiley & Sons Ltd.

  11. Determination of the absolute configurations of natural products via density functional theory calculations of optical rotation, electronic circular dichroism, and vibrational circular dichroism: the cytotoxic sesquiterpene natural products quadrone, suberosenone, suberosanone, and suberosenol A acetate.

    PubMed

    Stephens, P J; McCann, D M; Devlin, F J; Smith, A B

    2006-07-01

    The determination of the absolute configurations (ACs) of chiral molecules using the chiroptical techniques of optical rotation (OR), electronic circular dichroism (ECD), and vibrational circular dichroism (VCD) has been revolutionized by the development of density functional theory (DFT) methods for the prediction of these properties. Here, we demonstrate the significance of these advances for the stereochemical characterization of natural products. Time-dependent DFT (TDDFT) calculations of the specific rotations, [alpha](D), of four cytotoxic natural products, quadrone (1), suberosenone (2), suberosanone (3), and suberosenol A acetate (4), are used to assign their ACs. TDDFT calculations of the ECD of 1 are used to assign its AC. The VCD spectrum of 1 is reported and also used, together with DFT calculations, to assign its AC. The ACs of 1 derived from its [alpha](D), ECD, and VCD are identical and in agreement with the AC previously determined via total synthesis. The previously undetermined ACs of 2-4, derived from their [alpha](D) values, have absolute configurations of their tricyclic cores identical to that of 1. Further studies of the ACs of these molecules using ECD and, especially, VCD are recommended to establish more definitively this finding. Our studies of the OR, ECD, and VCD of quadrone are the first to utilize DFT calculations of all three properties for the determination of the AC of a chiral natural product molecule.

  12. Changing Practice Patterns and Long-term Outcomes of Endothelial Versus Penetrating Keratoplasty: A Prospective Dutch Registry Study.

    PubMed

    Dickman, Mor M; Peeters, Jean Marie P W U; van den Biggelaar, Frank J H M; Ambergen, Ton A W; van Dongen, Martin C J M; Kruit, Pieter Jan; Nuijts, Rudy M M A

    2016-10-01

    To compare graft survival, best-corrected visual acuity (BCVA), endothelial cell density (ECD), and refraction following penetrating keratoplasty (PK) vs endothelial keratoplasty (EK) for Fuchs endothelial dystrophy (FED) and pseudophakic bullous keratopathy (PBK). Nonrandomized treatment comparison with national registry data. All consecutive patients undergoing first keratoplasty for FED and PBK between 1998 and 2014 were analyzed, with a maximum follow-up of 5 years (mean ± SD follow-up 39 ± 20 months, range 0-60 months). Graft survival was analyzed using Kaplan-Meier survival curves and Cox regression analysis. BCVA, ECD, and refractive error were compared using linear mixed models. Main outcome measures were graft survival, BCVA, refraction, and ECD. A total of 5115 keratoplasties (PK = 2390; EK = 2725) were identified. Two-year graft survival following EK was lower compared with PK (94.5% vs 96.3%, HR = 1.56, P = .001). Five-year survival was comparable for EK and PK (93.4% vs 89.7%, HR = 0.89, P = .261). EK graft survival improved significantly over time while remaining stable for PK. One-year BCVA was better following EK vs PK (0.34 vs 0.47 logMAR, P < .001). Astigmatism was lower 1 year after EK vs PK (-1.69 vs -3.52 D, P < .001). One-year ECD was lower after EK vs PK (1472 vs 1859 cells/mm 2 , P < .001). At 3 years, ECD did not differ between EK and PK. Long-term graft survival after EK and PK is high and comparable despite lower short-term survival for EK. EK graft survival improved over time, suggesting a learning curve. EK results in better BCVA, lower astigmatism, and similar long-term ECD compared with PK for FED and PBK. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Early childhood development in Rwanda: a policy analysis of the human rights legal framework.

    PubMed

    Binagwaho, Agnes; Scott, Kirstin W; Harward, Sardis H

    2016-01-12

    Early childhood development (ECD) is a critical period that continues to impact human health and productivity throughout the lifetime. Failing to provide policies and programs that support optimal developmental attainment when such services are financially and logistically feasible can result in negative population health, education and economic consequences that might otherwise be avoided. Rwanda, with its commitment to rights-based policy and program planning, serves as a case study for examination of the national, regional, and global human rights legal frameworks that inform ECD service delivery. In this essay, we summarize key causes and consequences of the loss of early developmental potential and how this relates to the human rights legal framework in Rwanda. We contend that sub-optimal early developmental attainment constitutes a violation of individuals' rights to health, education, and economic prosperity. These rights are widely recognized in global, regional and national human rights instruments, and are guaranteed by Rwanda's constitution. Recent policy implementation by several Rwandan ministries has increased access to health and social services that promote achievement of full developmental potential. These ECD-centric activities are characterized by an integrated approach to strengthening the services provided by several public sectors. Combining population level activities with those at the local level, led by local community health workers and women's councils, can bolster community education and ensure uptake of ECD services. Realization of the human rights to health, education, and economic prosperity requires and benefits from attention to the period of ECD, as early childhood has the potential to be an opportunity for expedient intervention or the first case of human rights neglect in a lifetime of rights violations. Efforts to improve ECD services and outcomes at the population level require multisector collaboration at the highest echelons of government, as well as local education and participation at the community level.

  14. Pathogenic and multidrug-resistant Escherichia fergusonii from broiler chicken.

    PubMed

    Forgetta, V; Rempel, H; Malouin, F; Vaillancourt, R; Topp, E; Dewar, K; Diarra, M S

    2012-02-01

    An Escherichia spp. isolate, ECD-227, was previously identified from the broiler chicken as a phylogenetically divergent and multidrug-resistant Escherichia coli possessing numerous virulence genes. In this study, whole genome sequencing and comparative genome analysis was used to further characterize this isolate. The presence of known and putative antibiotic resistance and virulence open reading frames were determined by comparison to pathogenic (E. coli O157:H7 TW14359, APEC O1:K1:H7, and UPEC UTI89) and nonpathogenic species (E. coli K-12 MG1655 and Escherichia fergusonii ATCC 35469). The assembled genome size of 4.87 Mb was sequenced to 18-fold depth of coverage and predicted to contain 4,376 open reading frames. Phylogenetic analysis of 537 open reading frames present across 110 enteric bacterial species identifies ECD-227 to be E. fergusonii. The genome of ECD-227 contains 5 plasmids showing similarity to known E. coli and Salmonella enterica plasmids. The presence of virulence and antibiotic resistance genes were identified and localized to the chromosome and plasmids. The mutation in gyrA (S83L) involved in fluoroquinolone resistance was identified. The Salmonella-like plasmids harbor antibiotic resistance genes on a class I integron (aadA, qacEΔ-sul1, aac3-VI, and sulI) as well as numerous virulence genes (iucABCD, sitABCD, cib, traT). In addition to the genome analysis, the virulence of ECD-227 was evaluated in a 1-d-old chick model. In the virulence assay, ECD-227 was found to induce 18 to 30% mortality in 1-d-old chicks after 24 h and 48 h of infection, respectively. This study documents an avian multidrug-resistant and virulent E. fergusonii. The existence of several resistance genes to multiple classes of antibiotics indicates that infection caused by ECD-227 would be difficult to treat using antimicrobials currently available for poultry.

  15. Participation of the extracellular domain in (pro)renin receptor dimerization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suzuki-Nakagawa, Chiharu; Nishimura, Misa; Tsukamoto, Tomoko

    Highlights: • The (pro)renin receptor [(P)RR] is a regulator of the renin–angiotensin system. • The region responsible for (P)RR dimerization was investigated. • (P)RR extracellular domain constructs were retained intracellularly. • The extracellular domain of (P)RR is responsible for its dimerization. • Novel insight into the regulatory mechanism of soluble (P)RR secretion is provided. - Abstract: The (pro)renin receptor [(P)RR] induces the catalytic activation of prorenin, as well as the activation of the mitogen-activated protein kinase (MAPK) signaling pathway; as such, it plays an important regulatory role in the renin–angiotensin system. (P)RR is known to form a homodimer, but themore » region participating in its dimerization is unknown. Using glutathione S-transferase (GST) as a carrier protein and a GST pull-down assay, we investigated the interaction of several (P)RR constructs with full-length (FL) (P)RR in mammalian cells. GST fusion proteins with FL (P)RR (GST-FL), the C-terminal M8-9 fragment (GST-M8-9), the extracellular domain (ECD) of (P)RR (GST-ECD), and the (P)RR ECD with a deletion of 32 amino acids encoded by exon 4 (GST-ECDd4) were retained intracellularly, whereas GST alone was efficiently secreted into the culture medium when transiently expressed in COS-7 cells. Immunofluorescence microscopy showed prominent localization of GST-ECD to the endoplasmic reticulum. The GST pull-down analysis revealed that GST-FL, GST-ECD, and GST-ECDd4 bound FLAG-tagged FL (P)RR, whereas GST-M8-9 showed little or no binding when transiently co-expressed in HEK293T cells. Furthermore, pull-down analysis using His-tag affinity resin showed co-precipitation of soluble (P)RR with FL (P)RR from a stable CHO cell line expressing FL h(P)RR with a C-terminal decahistidine tag. These results indicate that the (P)RR ECD participates in dimerization.« less

  16. A sublimate sorbent for stir-bar sorptive extraction of aqueous endocrine disruptor pesticides for gas chromatography-electron capture detection.

    PubMed

    Huang, Yu-Wen; Lee, Hua Kwang; Shih, Hou-Kuang; Jen, Jen-Fon

    2018-06-06

    A dumbbell-shaped magnetic stir-bar with sublimate sorbent was prepared for the stir bar sorptive extraction (SBSE) of pesticides in an aqueous sample prior to gas chromatography-micro-electron capture detection (GC-μECD). Cyclododecane (CDD) was coated onto a magnetic stir-bar surface as a sublimate sorbent, and steel balls were placed on both ends to form a dumbbell-shaped magnetic stir-bar for SBSE. Four EDC pesticides including chlorpyrifos, ethion, bromopropylate, and λ-cyhalothrin in aqueous samples were selected as model species to examine the proposed SBSE and the following desorption. The parameters studied were those affecting the extraction efficiencies including the coating (solvent for CDD and thickness), extraction (sample pH, stirring rate, time, and salting out effect), dissolution solvent volume, and the loss of CDD sublimated in air. The maximum extraction efficiency was obtained under the following conditions. The stir bar (with CDD thickness of 5.2 μm) was added into a 10 mL sample solution (at pH 7) for a 20-min extraction at 600 rpm. Then, the stir bar was gently removed from the sample solution, disassembled, and immersed into a 0.2 mL insert tube consisting of 3 μL hexane to dissolve; 1 μL was used for GC-ECD analysis. The linear ranges were 0.005-5 μg L -1 with coefficients of determination ranging from 0.9950 - 0.9994. Detection limits (based on S/N = 3) of the four EDCs were 0.4-4.5 ngL -1 with a relative standard deviation (RSD) of 2.4-6.3%, and quantitation limits (based on S/N = 5) were 1-15 ngL -1 . The relative recoveries of the spiked samples were in the range of 83.2-98.7% with RSDs of 2.1-8.4% in farm field waters. The proposed sublimation sorbent obtained excellent enrichment factors (101-834) and provided a simple, rapid, sensitive, and eco-friendly sample preparation method. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Development of a solid-phase microextraction gas chromatography with microelectron-capture detection method for a multiresidue analysis of pesticides in bovine milk.

    PubMed

    Fernandez-Alvarez, Maria; Llompart, Maria; Lamas, J Pablo; Lores, Marta; Garcia-Jares, Carmen; Cela, Rafael; Dagnac, Thierry

    2008-06-09

    A simple and rapid method based on solid-phase microextraction (SPME) technique followed by gas chromatography with microelectron-capture detection (GC-microECD) was developed for the simultaneous determination of more than 30 pesticides (pyrethroids and organochlorinated among others) in milk. To our knowledge, this is the first application of SPME for the determination of pyrethroid pesticides in milk. Negative matrix effects due to the complexity and lipophility of the studied matrix were reduced by diluting the sample with distilled water. A 2(5-1) fractional factorial design was performed to assess the influence of several factors (type of fiber coating, sampling mode, stirring, extraction temperature, and addition of sodium chloride) on the SPME procedure and to determine the optimal extraction conditions. After optimization of all the significant variables and interactions, the recommended procedure was established as follows: DSPME (using a polydimethylsiloxane (PDMS)/divinylbenzene (DVB) coating) of 1 mL of milk sample diluted with Milli-Q water (1:10 dilution ratio), at 100 degrees C, under stirring for 30 min. The proposed method showed good linearity and high sensitivity, with limits of detection (LOD) at the sub-ng mL(-1) level. Within a day and among days precisions were also evaluated (R.S.D.<15%). One of the most important attainments of this work was the use of external calibration with milk-matched standards to quantify the levels of the target analytes. The method was tested with liquid and powdered milk samples with different fat contents covering the whole commercial range. The efficiency of the extraction process was studied at several analyte concentration levels obtaining high recoveries (>80% in most cases) for different types of full-fat milks. The optimized procedure was validated with powdered milk certified reference material, which was quantified using external calibration and standard addition protocols. Finally, the DSPME-GC-microECD methodology was applied to the analysis of milk samples collected in farms of dairy cattle from NW Spain.

  18. Development of a solid-phase microextraction gas chromatography with microelectron-capture detection method for the determination of 5-bromo-5-nitro-1,3-dioxane in rinse-off cosmetics.

    PubMed

    Fernandez-Alvarez, Maria; Lamas, J Pablo; Sanchez-Prado, Lucia; Llompart, Maria; Garcia-Jares, Carmen; Lores, Marta

    2010-10-22

    5-Bromo-5-nitro-1,3-dioxane (bronidox) is a bromine-containing preservative often used in rinse-off cosmetics but also subjected to several restrictions according to the European Cosmetic Products Regulation. Thus, as a part of a quality control procedure, analytical methods for the determination of this compound in different types of cosmetics are required. In the present work, a solvent-free and simple methodology based on solid-phase microextraction (SPME) followed by gas chromatography with microelectron capture detection (GC-μECD) has been developed and validated for the determination of bronidox in cosmetic samples such as shampoos, body cleansers or facial exfoliants. As far as we know, this is the first application of SPME to this preservative. Negative matrix effects due to the complexity of the studied samples were reduced by dilution with ultrapure water. The influence of several factors on the SPME procedure such as fiber coating, extraction temperature, salt addition (NaCl) and sampling mode has been assessed by performing a 2(4)-factorial design. After optimization, the recommended procedure was established as follows: direct solid-phase microextraction (DSPME), using a PDMS/DVB coating, of 10 mL of diluted cosmetic with 20% NaCl, at room temperature, under stirring for 30 min. Using these suggested extraction conditions, linear calibration could be achieved, with limits of detection (LOD) and quantification (LOQ) well below the maximum authorized concentration (0.1%) established by the European legislation. Relative standard deviations (RSD) lower than 10% were obtained for both within a day and among days precision. The method was applied to diverse types of formulations spiked with bronidox at different concentration levels (0.008-0.10%); these samples were quantified by external calibration and satisfactory recoveries (≥ 70%) were obtained in all cases. Finally, the SPME-GC-μECD methodology was applied to the analysis of several cosmetics labeled or not as containing bronidox. The presence of this preservative in some of these samples was confirmed by GC-MS. Copyright © 2010 Elsevier B.V. All rights reserved.

  19. Measurements of N2O and SF6 for use in Inverse Model Studies

    NASA Astrophysics Data System (ADS)

    Dlugokencky, E. J.; Peters, W.; Masarie, K. A.; Lang, P. M.; Dutton, G.; Hall, B. D.

    2004-12-01

    NOAA CMDL makes measurements of atmospheric nitrous oxide (N2O) and sulfur hexafluoride (SF6) mole fractions in discrete air samples from ˜60 surface sites and ˜10 vertical profile sites for use in inverse modeling. Measurements are made by gas chromatography with electron capture detection (ECD) relative to standard scales developed in CMDL's Halocarbons and Other Atmospheric Trace Species (HATS) group. Uncertainties in the standard scales (95% confidence limits) are 0.8 nmol mol-1 for N2O and 0.05 pmol mol-1 for SF6. For N2O, the ECD response is characterized monthly by a second-order polynomial with a suite of 6 secondary standards covering the range 242-343 nmol mol-1. An instrument response function prepared from measurements of the secondary standards relative to a reference cylinder is used to quantify samples. SF6 in air samples is quantified with the reference by assuming a linear response with zero intercept in samples that are free of SF6. Reproducibility of the measurements, based on agreement between two samples collected in series, is ˜0.4 nmol mol-1 for N2O and ˜0.04 pmol mol-1 for SF6. So far, all measurements have been made on a single analytical system. The measurements impose important constraints on the budgets of N2O and SF6 based on observed trends, changes in trends, and spatial gradients. These parameters can be used to determine source/sink imbalances, changes in emission rates over time, and the distribution of emissions. In addition, Peters et al. [JGR, in press, 2004] have used the SF6 measurements to evaluate transport in the two-way nested chemistry transport model, TM5. They found that TM5 captures vertical gradients and synoptic variability in SF6 well at both MBL and continental sampling sites, but it over-estimates the meridional gradient by ˜19%. The SF6 data also suggest that global SF6 emissions increased by ˜20% during late-2002.

  20. Neutron detector

    DOEpatents

    Stephan, Andrew C [Knoxville, TN; Jardret,; Vincent, D [Powell, TN

    2011-04-05

    A neutron detector has a volume of neutron moderating material and a plurality of individual neutron sensing elements dispersed at selected locations throughout the moderator, and particularly arranged so that some of the detecting elements are closer to the surface of the moderator assembly and others are more deeply embedded. The arrangement captures some thermalized neutrons that might otherwise be scattered away from a single, centrally located detector element. Different geometrical arrangements may be used while preserving its fundamental characteristics. Different types of neutron sensing elements may be used, which may operate on any of a number of physical principles to perform the function of sensing a neutron, either by a capture or a scattering reaction, and converting that reaction to a detectable signal. High detection efficiency, an ability to acquire spectral information, and directional sensitivity may be obtained.

  1. Thermal neutron radiative capture on cadmium as a counting technique at the INES beam line at ISIS: A preliminary investigation of detector cross-talk.

    PubMed

    Festa, G; Grazzi, F; Pietropaolo, A; Scherillo, A; Schooneveld, E M

    2017-12-01

    Experimental tests are presented that assess the cross-talk level among three scintillation detectors used as neutron counters exploiting the thermal neutron radiative capture on Cd. The measurements were done at the INES diffractometer operating at the ISIS spallation neutron source (Rutherford Appleton Laboratory, UK). These tests follow a preliminary set of measurements performed on the same instrument to study the effectiveness of this thermal neutron counting strategy in neutron diffraction measurements, typically performed on INES using squashed 3 He filled gas tubes. The experimental data were collected in two different geometrical configurations of the detectors and compared to results of Monte Carlo simulations, performed using the MCNP code. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Radiative neutron capture as a counting technique at pulsed spallation neutron sources: a review of current progress

    NASA Astrophysics Data System (ADS)

    Schooneveld, E. M.; Pietropaolo, A.; Andreani, C.; Perelli Cippo, E.; Rhodes, N. J.; Senesi, R.; Tardocchi, M.; Gorini, G.

    2016-09-01

    Neutron scattering techniques are attracting an increasing interest from scientists in various research fields, ranging from physics and chemistry to biology and archaeometry. The success of these neutron scattering applications is stimulated by the development of higher performance instrumentation. The development of new techniques and concepts, including radiative capture based neutron detection, is therefore a key issue to be addressed. Radiative capture based neutron detectors utilize the emission of prompt gamma rays after neutron absorption in a suitable isotope and the detection of those gammas by a photon counter. They can be used as simple counters in the thermal region and (simultaneously) as energy selector and counters for neutrons in the eV energy region. Several years of extensive development have made eV neutron spectrometers operating in the so-called resonance detector spectrometer (RDS) configuration outperform their conventional counterparts. In fact, the VESUVIO spectrometer, a flagship instrument at ISIS serving a continuous user programme for eV inelastic neutron spectroscopy measurements, is operating in the RDS configuration since 2007. In this review, we discuss the physical mechanism underlying the RDS configuration and the development of associated instrumentation. A few successful neutron scattering experiments that utilize the radiative capture counting techniques will be presented together with the potential of this technique for thermal neutron diffraction measurements. We also outline possible improvements and future perspectives for radiative capture based neutron detectors in neutron scattering application at pulsed neutron sources.

  3. The Promises and Challenges of Implementing Evidence-Centered Design in Large Scale Assessment

    ERIC Educational Resources Information Center

    Huff, Kristen; Steinberg, Linda; Matts, Tom

    2009-01-01

    Presented at the Annual Meeting of National Council on Measurement in Education (NCME) in San Diego, CA in April 2009. This presentation provides an overview of ECD. In addition, the presentation describes the benefits of, as well as the challenges that were faced, in implementing ECD in the Advanced Placement Program.

  4. 77 FR 27661 - Airworthiness Directives; Eurocopter Deutschland GmbH Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-11

    ... Deutschland GmbH Helicopters AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed... Deutschland GmbH (ECD) model EC135 helicopters, except the EC 135 P2+ and T2+. This proposed AD was prompted...) Applicability This AD applies to all Eurocopter Deutschland GmbH (ECD) Model EC135 helicopters, except EC 135 P2...

  5. 77 FR 72913 - Airworthiness Directives; Eurocopter Deutschland GmbH Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-07

    ... Airworthiness Directives; Eurocopter Deutschland GmbH Helicopters AGENCY: Federal Aviation Administration (FAA... Eurocopter Deutschland GmbH (ECD) Model EC135 helicopters, except the EC 135 P2+ and T2+. This AD requires... apply to all Eurocopter Deutschland GmbH (ECD) model EC135 helicopters, except the EC 135 P2+ and T2...

  6. Unusual dimeric tetrahydroxanthone derivatives from Aspergillus lentulus and the determination of their axial chiralities

    NASA Astrophysics Data System (ADS)

    Li, Tian-Xiao; Yang, Ming-Hua; Wang, Ying; Wang, Xiao-Bing; Luo, Jun; Luo, Jian-Guang; Kong, Ling-Yi

    2016-12-01

    The research on secondary metabolites of Aspergillus lentulus afforded eight unusual heterodimeric tetrahydroxanthone derivatives, lentulins A-H (2-9), along with the known compound neosartorin (1). Compounds 1-6 exhibited potent antimicrobial activities especially against methicillin-resistant Staphylococci. Their absolute configurations, particularly the axial chiralities, were unambiguously demonstrated by a combination of electronic circular dichroism (ECD), Rh2(OCOCF3)4-induced ECD experiments, modified Mosher methods, and chemical conversions. Interestingly, compounds 1-4 were the first samples of atropisomers within the dimeric tetrahydroxanthone class. Further investigation of the relationships between their axial chiralities and ECD Cotton effects led to the proposal of a specific CD Exciton Chirality rule to determine the axial chiralities in dimeric tetrahydroxanthones and their derivatives.

  7. Exciton coupling between enones: Quassinoids revisited.

    PubMed

    Pescitelli, Gennaro; Di Bari, Lorenzo

    2017-09-01

    The electronic circular dichroism (ECD) spectra of two previously reported quassinoids containing a pair of enone chromophores are revisited to gain insight into the consistency and applicability of the exciton chirality method. Our study is based on time-dependent Density Functional Theory calculations, transition and orbital analysis, and numerical exciton coupling calculations. In quassin (1) the enone/enone exciton coupling is quasi-degenerate, yielding strong rotational strengths that account for the observed ECD spectrum in the enone π-π* region. In perforalactone C (2) the nondegenerate coupling produces weak rotational strengths, and the ECD spectrum is dominated by other mechanisms of optical activity. We remark the necessity of a careful application of the nondegenerate exciton coupling method in similar cases. © 2017 Wiley Periodicals, Inc.

  8. OAT3-mediated extrusion of the 99mTc-ECD metabolite in the mouse brain

    PubMed Central

    Kikuchi, Tatsuya; Okamura, Toshimitsu; Wakizaka, Hidekatsu; Okada, Maki; Odaka, Kenichi; Yui, Joji; Tsuji, Atsushi B; Fukumura, Toshimitsu; Zhang, Ming-Rong

    2014-01-01

    After administration of the 99mTc complex with N,N'-1,2-ethylenediylbis-L-cysteine diethyl ester (99mTc-ECD), a brain perfusion imaging agent, the radioactive metabolite is trapped in primate brain, but not in mouse and rat. Here, we investigate the involvement of metabolite extrusion by organic anion transporter 3 (OAT3), which is highly expressed at the blood–brain barrier in mice, in this species difference. The efflux rate of radioactivity in the cerebrum of Oat3−/− mice at later phase was 20% of that of control mice. Thus, organic anion transporters in mouse brain would be involved in the low brain retention of radioactivity after 99mTc-ECD administration. PMID:24496177

  9. Development of a one-step immunochromatographic strip test for the detection of sennosides A and B.

    PubMed

    Putalun, Waraporn; Morinaga, Osamu; Tanaka, Hiroyuki; Shoyama, Yukihiro

    2004-01-01

    An immunochromatographic strip test was developed to detect sennoside A (1) and sennoside B (2) using anti-1 and anti-2 monoclonal antibodies. The qualitative assay was based on a competitive immunoassay in which the detector reagent consisted of colloidal gold particles coated with the respective sennoside antibodies. The capture reagents were 1- and 2-human serum albumin (HSA) conjugates immobilised on a nitrocellulose membrane on the test strip. The sample containing 1 and 2, together with detector reagent, passed over the zone where the capture reagents had been immobilised. The analytes in the sample competed for binding to the limited amount of antibodies in the detector reagent with the immobilised 1- and 2-HSA conjugates on the membrane and hence positive samples showed no colour in the capture spot zone. Detection limits for the strip test were 125 ng/mL for both sennosides. The assay system is useful as a rapid and simple screening method for the detection of 1 and 2 in plants, drugs and body fluids.

  10. Enhanced sampling molecular dynamics simulation captures experimentally suggested intermediate and unfolded states in the folding pathway of Trp-cage miniprotein.

    PubMed

    Shao, Qiang; Shi, Jiye; Zhu, Weiliang

    2012-09-28

    The ability of molecular dynamics simulation to capturing the transient states within the folding pathway of protein is important to the understanding of protein folding mechanism. In the present study, the integrated-tempering-sampling molecular dynamics (ITS-MD) simulation was performed to investigate the transient states including intermediate and unfolded ones in the folding pathway of a miniprotein, Trp-cage. Three force fields (FF03, FF99SB, and FF96) were tested, and both intermediate and unfolded states with their characteristics in good agreement with experiments were observed during the simulations, which supports the hypothesis that observable intermediates might present in the folding pathway of small polypeptides. In addition, it was demonstrated that FF03 force field as combined with ITS-MD is in overall a more proper force field than the others in reproducing experimentally recorded properties in UVRS, ECD, and NMR, Photo-CIDNP NMR, and IR T-jump experiments, and the folding∕unfolding thermodynamics parameters, such as ΔG(U), ΔC(p), and ΔH(U) (T(m)). In summary, the present study showed that using suitable force field and energy sampling method, molecular dynamics simulation could capture the transient states within the folding pathway of protein which are consistent with the experimental measurements, and thus provide information of protein folding mechanism and thermodynamics.

  11. Assessment of pesticide residues in army cutworm moths (Euxoa auxiliaris) from the Greater Yellowstone Ecosystem and their potential consequences to foraging grizzly bears (Ursus arctos horribilis).

    PubMed

    Robison, Hillary L; Schwartz, Charles C; Petty, Jim D; Brussard, Peter F

    2006-09-01

    During summer, a grizzly bear (Ursus arctos horribilis) in the Greater Yellowstone Ecosystem (GYE) (USA) can excavate and consume millions of army cutworm moths (Euxoa auxiliaris) (ACMs) that aggregate in high elevation talus. Grizzly bears in the GYE were listed as threatened by the US Fish and Wildlife Service in 1975 and were proposed for delisting in 2005. However, questions remain about key bear foods. For example, ACMs are agricultural pests and concern exists about whether they contain pesticides that could be toxic to bears. Consequently, we investigated whether ACMs contain and transport pesticides to bear foraging sites and, if so, whether these levels could be toxic to bears. In 1999 we collected and analyzed ACMs from six bear foraging sites. ACMs were screened for 32 pesticides with gas chromatography with electron capture detection (GC-ECD). Because gas chromatography with tandem mass spectrometry (GC-MS/MS) can be more sensitive than GC-ECD for certain pesticides, we revisited one site in 2001 and analyzed these ACMs with GC-MS/MS. ACMs contained trace or undetectable levels of pesticides in 1999 and 2001, respectively. Based on chemical levels in ACMs and numbers of ACMs a bear can consume, we calculated the potential of chemicals to reach physiological toxicity. These calculations indicate bears do not consume physiologically toxic levels of pesticides and allay concerns they are at risk from pesticides transported by ACMs. If chemical control of ACMs changes in the future, screening new ACM samples taken from bear foraging sites may be warranted.

  12. Biotic and abiotic transformations of methyl tertiary butyl ether (MTBE).

    PubMed

    Fischer, Axel; Oehm, Claudia; Selle, Michael; Werner, Peter

    2005-11-01

    Methyl tertiary butyl ether (MTBE) is a fuel additive which is used all over the world. In recent years it has often been found in groundwater, mainly in the USA, but also in Europe. Although MTBE seems to be a minor toxic, it affects the taste and odour of water at concentrations of < 30 microg/L. Although MTBE is often a recalcitrant compound, it is known that many ethers can be degraded by abiotic means. The aim of this study was to examine biotic and abiotic transformations of MTBE with respect to the particular conditions of a contaminated site (former refinery) in Leuna, Germany. Groundwater samples from wells of a contaminated site were used for aerobic and anaerobic degradation experiments. The abiotic degradation experiment (hydrolysis) was conducted employing an ion-exchange resin and MTBE solutions in distilled water. MTBE, tertiary butyl formate (TBF) and tertiary butyl alcohol (TBA) were measured by a gas chromatograph with flame ionisation detector (FID). Aldehydes and organic acids were respectively analysed by a gas chromatograph with electron capture detector (ECD) and high-performance ion chromatography (HPIC). Under aerobic conditions, MTBE was degraded in laboratory experiments. Only 4 of a total of 30 anaerobic experiments exhibited degradation, and the process was very slow. In no cases were metabolites detected, but a few degradation products (TBF, TBA and formic acid) were found on the site, possibly due to the lower temperatures in groundwater. The abiotic degradation of MTBE with an ion-exchange resin as a catalyst at pH 3.5 was much faster than hydrolysis in diluted hydrochloric acid (pH 1.0). Although the aerobic degradation of MTBE in the environment seems to be possible, the specific conditions responsible are widely unknown. Successful aerobic degradation only seems to take place if there is a lack of other utilisable compounds. However, MTBE is often accompanied by other fuel compounds on contaminated sites and anaerobic conditions prevail. MTBE is often recalcitrant under anaerobic conditions, at least in the presence of other carbon sources. The abiotic hydrolysis of MTBE seems to be of secondary importance (on site), but it might be possible to enhance it with catalysts. MTBE only seems to be recalcitrant under particular conditions. In some cases, the degradation of MTBE on contaminated sites could be supported by oxygen. Enhanced hydrolysis could also be an alternative.

  13. Ferrocene-oligonucleotide conjugates for electrochemical probing of DNA.

    PubMed Central

    Ihara, T; Maruo, Y; Takenaka, S; Takagi, M

    1996-01-01

    Toward the development of a universal, sensitive and convenient method of DNA (or RNA) detection, electrochemically active oligonucleotides were prepared by covalent linkage of a ferrocenyl group to the 5'-aminohexyl-terminated synthetic oligonucleotides. Using these electrochemically active probes, we have been able to demonstrate the detection of DNA and RNA at femtomole levels by HPLC equipped with an ordinary electrochemical detector (ECD) [Takenaka,S., Uto,Y., Kondo,H., Ihara,T. and Takagi,M. (1994) Anal. Biochem., 218, 436-443]. Thermodynamic and electrochemical studies of the interaction between the probes and the targets are presented here. The thermodynamics obtained revealed that the conjugation stabilizes the triple-helix complexes by 2-3 kcal mol-1 (1-2 orders increment in binding constant) at 298 K, which corresponds to the effect of elongation of additional several base triplets. The main cause of this thermodynamic stabilization by the conjugation is likely to be the overall conformational change of whole structure of the conjugate rather than the additional local interaction. The redox potential of the probe was independent of the target structure, which is either single- or double stranded. However, the potential is slightly dependent (with a 10-30 mV negative shift on complexation) on the extra sequence in the target, probably because the individual sequence is capable of contacting or interacting with the ferrocenyl group in a slightly different way from each other. This small potential shift itself, however, does not cause any inconvenience on practical applications in detecting the probes by using ECD. These results lead to the conclusion that the redox-active probes are very useful for the microanalysis of nucleic acids due to the stability of the complexes, high detection sensitivity and wide applicability to the target structures (DNA and RNA; single- and double strands) and the sequences. PMID:8932383

  14. Neutron radiative capture methods for surface elemental analysis

    USGS Publications Warehouse

    Trombka, J.I.; Senftle, F.; Schmadebeck, R.

    1970-01-01

    Both an accelerator and a 252Cf neutron source have been used to induce characteristic gamma radiation from extended soil samples. To demonstrate the method, measurements of the neutron-induced radiative capture and activation gamma rays have been made with both Ge(Li) and NaI(Tl) detectors, Because of the possible application to space flight geochemical analysis, it is believed that NaI(Tl) detectors must be used. Analytical procedures have been developed to obtain both qualitative and semiquantitative results from an interpretation of the measured NaI(Tl) pulse-height spectrum. Experiment results and the analytic procedure are presented. ?? 1970.

  15. Cleanup procedure for water, soil, animal and plant extracts for the use of electron-capture detector in the gas chromatographic analysis of organophosphorus insecticide residues.

    PubMed

    Kadoum, A M

    1968-07-01

    A simple, aqueous acetonitrile partition cleanup method for analyses of some common organophosphorus insecticide residues is described. The procedure described is for cleanup and quantitative recovery of parathion, methyl parathion, diazinon, malathion and thimet from different extracts. Those insecticides in the purified extracts of ground water, grain, soil, plant and animal tissues can be detected quantitatively by gas chromatography with an electron capture-detector at 0.01 ppm. Cleanup is satisfactory for paper and thin-layer chromatography for further identification of individual insecticides in the extracts.

  16. Lindane residues in cultivated cucumber and in the most consumed fish in Caspian Sea (Iran).

    PubMed

    Shokrzadeh, M; Saeedi Saravi, S S; Zehtab Yazdi, Y

    2009-09-01

    In this study, the concentrations of lindane residues (organochlorine pesticides) were analyzed in samples of cultivated cucumbers (Cucumis sativus L.) and four species of most consumed fish (Sefid, Koli, Kilca and Kafal fish). Samples of cucumber were collected from five sites in Sari city (north, south, east, west and central areas) and samples of fish were caught using electric fishing from four major fishing centers (Chalous and Babolsar cities, Khazar Abad and Miankaleh regions) in Mazandaran province of Iran. Quantitative determination of the lindane content was performed by gas chromatography electron-capture detection (GC-ECD). The results showed that the concentration of lindane in cucumber samples and in the dorsal muscle of the selected fish were less than the Food and Agriculture Organization/World Health Organization (FAO/WHO) recommended intake.

  17. Sky Radiance Distributions for Thermal Imaging Backgrounds.

    DTIC Science & Technology

    1987-12-01

    background noise limited system. In infrared devices we have a spectral discrimination which is due to the spectral response of the detector /filter...cannot apply the central limit theorem [Ref.]- because the detector can capture only a few shots of the cloud form and the characteristics of the...objects most infrared systems can be used as detectors or target designators. Since infrared systems are passive the advantages of such systems are enormous

  18. A comprehensive analysis of eye bank-prepared posterior lamellar corneal tissue for use in endothelial keratoplasty.

    PubMed

    Kelliher, Clare; Engler, Christoph; Speck, Caroline; Ward, Don; Farazdaghi, Sameera; Jun, Albert S

    2009-10-01

    The purpose of this study was to assess eye bank-prepared corneal tissue with regards to the accuracy of postcut tissue thickness, endothelial cell loss, and rate of successful processing. Details of all 913 corneal tissues processed with an automated microkeratome for use in posterior lamellar transplantation, over a 1-year period, were obtained from a large eye bank. The number and success rate of all attempted cutting procedures were analyzed. The thickness of the corneal button obtained after cutting was compared with the graft thickness requested by the operating surgeon. Changes in endothelial cell density (ECD) during tissue processing were evaluated. The rate of successful tissue preparation increased over the time period examined, from 95% in the first quarter to 99.5% in the fourth quarter. Graft material was frequently slightly thicker than requested by the operating surgeon with 28.3% of tissues cut thicker than requested. Postcut ECD over the entire period increased by an average of 4.7% and was closely related to the starting ECD. There was a very high rate of successful tissue preparation (98.5%), and early failed attempts at tissue cutting were likely the result of the initial learning curve of the involved technicians. Practical considerations resulted in tissue being cut marginally thicker than requested; this is an issue about which the operating surgeon should be aware, because it may possibly influence tissue handling. The quality of the obtained material, as measured by ECD, was excellent, although the calculated ECD may be prone to measurement artifact.

  19. Ophthalmic features of spinocerebellar ataxia type 7.

    PubMed

    Campos-Romo, A; Graue-Hernandez, E O; Pedro-Aguilar, L; Hernandez-Camarena, J C; Rivera-De la Parra, D; Galvez, V; Diaz, R; Jimenez-Corona, A; Fernandez-Ruiz, J

    2018-01-01

    PurposeTo analyze the relation between ophthalmologic and motor changes in spinocerebellar ataxia type 7 (SCA7).Patients and methodsThis was a case series study. Sixteen SCA7 patients underwent a comprehensive ophthalmic examination, including ocular extrinsic motility testing, color vision test, and optical coherence tomography of the optic nerve and macula. Changes in the corneal endothelium, electroretinographic patterns, and a complete neurologic evaluation using the Scale for the Assessment and Rating of Ataxia (SARA) were evaluated. Correlations of endothelial cell density (ECD) with number of CAG repetitions and the SARA scores were estimated.ResultsAll patients showed various degrees of visual impairment mainly due to macular deterioration. Notably, they also presented decreased ECD. Pairwise correlations of ECD with number of CAG repeats and severity of motor symptoms quantified with the SARA scores were inverse (r=-0.46, P=0.083 and r=-0.64, P=0.009, respectively). Further analyses indicated an average ECD decrease of 48 cells/mm 2 (P=0.006) per unit of change on the number of CAG repeats, and of 75 cells/mm 2 (P=0.001) per unit of change on the SARA scores.ConclusionsThe results agree with previous ophthalmological findings regarding the widespread effect of SCA7 mutation on the patient's visual system. However, the results also show a significant negative correlation of decreased ECD with both CAG repetitions and SARA scores. This suggests that motor systems could degenerate in parallel with visual systems, although more research is needed to determine whether the degeneration is caused by the same mechanisms.

  20. Absolute configurations of phytotoxins seiricardine A and inuloxin A obtained by chiroptical studies.

    PubMed

    Santoro, Ernesto; Mazzeo, Giuseppe; Petrovic, Ana G; Cimmino, Alessio; Koshoubu, Jun; Evidente, Antonio; Berova, Nina; Superchi, Stefano

    2015-08-01

    The absolute configuration (AC) of the plant phytotoxin inuloxin A, produced by Inula viscosa, and of the fungal phytotoxin seiricardine A, obtained from Seiridium fungi, pathogen for cypress, has been determined by experimental measurements and theoretical simulations of chiroptical properties of three related methods, namely, Optical Rotatory Dispersion (ORD), Electronic Circular Dichroism (ECD), and Vibrational Circular Dichroism (VCD). Computational prediction by Density Functional Theory (DFT) of VCD spectra and by Time-dependent DFT (TDDFT) of ORD and ECD spectra allowed to assign (7R,8R,10S) AC to naturally occurring (+)-inuloxin A. In the case of compound (-)-seiricardine A, which lacks useful for the analysis UV-Vis absorption, and thus provides a hardly detectable ECD spectrum and quite low ORD values, an introduction of a suitable chromophore by chemical derivatization was performed. The corresponding derivative, 2-O-p-bromobenzoate ester, gave rise to an intense ECD spectrum and higher ORD and VCD values. The comparison of computed spectra with the experimental ones allowed to assign (1S,2R,3aS,4S,5R,7aS) AC to (-)-2-O-p-bromobenzoate ester of seiricardine A and then to (-)-seiricardine A. This study further supports a recent trend of concerted application of more than a single chiroptical technique toward an unambiguous assignment of AC of flexible and complex natural products. Moreover, the use of chemical derivatization, with insertion of suitable chromophoric moieties has allowed to treat also UV-Vis transparent molecules by ECD and ORD spectroscopies. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Assessing the Impact of Diabetes Mellitus on Donor Corneal Endothelial Cell Density.

    PubMed

    Liaboe, Chase A; Aldrich, Benjamin T; Carter, Pamela C; Skeie, Jessica M; Burckart, Kimberlee A; Schmidt, Gregory A; Reed, Cynthia R; Zimmerman, M Bridget; Greiner, Mark A

    2017-05-01

    To quantify changes in endothelial cell density (ECD) of donor corneal tissue in relation to the presence or absence of a medical history of diabetes mellitus diagnosis, treatment, and complications. A retrospective review was performed for all corneas collected at Iowa Lions Eye Bank between January 2012 and December 2015. For purposes of analysis, donor corneas were divided into 4 groups: nondiabetic, non-insulin-dependent diabetic, insulin-dependent diabetic without medical complications due to diabetes, and insulin-dependent diabetic with medical complications due to diabetes. ECD values (obtained through specular microscopy) and transplant suitability for endothelial transplantation (determined by the standard protocol of the eye bank) were compared among groups using linear mixed model analysis. In total, 4185 corneas from 2112 donors were included for analysis. Insulin-dependent diabetic samples with medical complications due to diabetes (N = 231 from 119 donors) showed lower ECD values compared with nondiabetic samples (-102 cells/mm, P = 0.049) and non-insulin-dependent diabetic samples (-117 cells/mm, P = 0.031). ECD values did not differ significantly among the remaining groups. The likelihood of suitability for endothelial transplantation did not differ among all 4 groups. Corneas from donors with insulin-dependent diabetes mellitus and medical complications resulting from the disease have lower mean ECD values compared with other donors. However, our analysis suggests that these corneas are equally likely to be included in the donor pool for corneal transplantation. Additional studies are needed to determine the mechanism(s) contributing to cell loss in donors with advanced diabetes and to assess associated endothelial cell functional impairment.

  2. Identifying Key Features of Student Performance in Educational Video Games and Simulations through Cluster Analysis

    ERIC Educational Resources Information Center

    Kerr, Deirdre; Chung, Gregory K. W. K.

    2012-01-01

    The assessment cycle of "evidence-centered design" (ECD) provides a framework for treating an educational video game or simulation as an assessment. One of the main steps in the assessment cycle of ECD is the identification of the key features of student performance. While this process is relatively simple for multiple choice tests, when…

  3. 78 FR 52410 - Airworthiness Directives; Eurocopter Deutschland GmbH Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-23

    ... Airworthiness Directives; Eurocopter Deutschland GmbH Helicopters AGENCY: Federal Aviation Administration (FAA... Deutschland GmbH (ECD) Model BO-105A, BO-105C, BO-105S, BO- 105LS A-1, BO-105LS A-3, MBB-BK 117 A-1, MBB-BK... directive (AD): 2013-16-13 Eurocopter Deutschland GmbH (ECD): Amendment 39-17551; Docket No. FAA-2012-0887...

  4. RESEARCH NOTE: INTERFERENCES DUE TO OZONE-SCAVENGING REAGENTS IN THE GC-ECD DETERMINATION OF ALDEHYDES AND KETONS AS THE O-(2,3,4,5,6-PENTAFLUOROBENZYL)OXIMES

    EPA Science Inventory

    Six potential ozone-scavenging reagents were tested for possible interference in the GC-ECD determination of aldehydes and ketones after derivatization with O-(2,3,4,5,6-pentafluorobenzyl)oxylamine (PFBOA). All six-nitrite, cynaide, methanoate (formate), indigo-55'-disulfonate d...

  5. Green preparation of carbon dots with papaya as carbon source for effective fluorescent sensing of Iron (III) and Escherichia coli.

    PubMed

    Wang, Ning; Wang, Yiting; Guo, Tingting; Yang, Ting; Chen, Mingli; Wang, Jianhua

    2016-11-15

    A simple one-step hydrothermal green approach was reported for the preparation of carbon dots (CDs) without any further decoration or modification with papaya powder as natural carbon source. In this economical and eco-friendly system, deionized water or 90% ethanol was used as solvent to produce water-soluble or ethanol-soluble CDs, respectively, termed as W-CDs and E-CDs. The quantum yield (QY) for W-CDs was 18.98%, while that for E-CDs was 18.39%. The potentials of the prepared carbon dots toward diverse applications were thoroughly investigated. W-CDs and E-CDs provide promising probes for fluorescence detection of Fe(3+), offering limits of detection of 0.48μmolL(-1) and 0.29μmolL(-1), respectively. W-CDs was further demonstrated to be a promising probe for fluorescence sensing of Escherichia coli O157: H7, along with a limit of detection of 9.5×10(4)cfumL(-1). Meanwhile, both W-CDs and E-CDs exhibit favorable biocompatibility, and demonstrated to be efficient for Hela cell imaging. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Psychometric properties of the Portuguese version of the Depressive Cognition Scale in Brazilian adults with diabetes mellitus.

    PubMed

    Sousa, Valmi D; Zanetti, Maria L; Zauszniewski, Jaclene A; Mendes, Isabel A C; Daguano, Michelle O

    2008-01-01

    Identifying depressive cognitions in Brazilians with diabetes can be important step to prevent the development of clinical depression, which is negatively associated with diabetes self-management. This study focused on the psychometric testing of the Portuguese version of the Depressive Cognition Scale, the Escala Cognitiva de Depressão (ECD), among 82 Brazilian adults with diabetes mellitus. The questionnaire was assessed for internal consistency, homogeneity, and construct validity using factor analysis and convergent validity assessment with the Portuguese version of the Beck Depression Inventory, the Inventário de Depressão Beck (IDB). Cronbach's alpha for the ECD was .88. The homogeneity of the instrument was supported by item-to-total correlations between .30 and .70. Factor extraction generated only one factor with eigenvalues greater than 1, which is consistent with the English version. The ECD's total score had a weak but significant correlation with the IDB's total score (r = .24, p < .05), indicating convergent validity. Evidence for the reliability and construct validity of the ECD was provided by this study. This scale has the potential to become a useful screening tool for depressive cognitions among Brazilians with diabetes.

  7. Simulation of Electronic Circular Dichroism of Nucleic Acids: From the Structure to the Spectrum.

    PubMed

    Padula, Daniele; Jurinovich, Sandro; Di Bari, Lorenzo; Mennucci, Benedetta

    2016-11-14

    We present a quantum mechanical (QM) simulation of the electronic circular dichroism (ECD) of nucleic acids (NAs). The simulation combines classical molecular dynamics, to obtain the structure and its temperature-dependent fluctuations, with a QM excitonic model to determine the ECD. The excitonic model takes into account environmental effects through a polarizable embedding and uses a refined approach to calculate the electronic couplings in terms of full transition densities. Three NAs with either similar conformations but different base sequences or similar base sequences but different conformations have been investigated and the results were compared with experimental observations; a good agreement was seen in all cases. A detailed analysis of the nature of the ECD bands in terms of their excitonic composition was also carried out. Finally, a comparison between the QM and the DeVoe models clearly revealed the importance of including fluctuations of the excitonic parameters and of accurately determining the electronic couplings. This study demonstrates the feasibility of the ab initio simulation of the ECD spectra of NAs, that is, without the need of experimental structural or electronic data. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. A job analysis of community health workers in the context of integrated nutrition and early child development.

    PubMed

    Phuka, John; Maleta, Kenneth; Thomas, Mavuto; Gladstone, Melisa

    2014-01-01

    Stunting and poor child development are major public health concerns in Malawi. Integrated nutrition and early child development (ECD) interventions have shown potential to reduce stunting, but it is not known how these integrated approaches can be implemented in Malawi. In this paper, we aimed to evaluate the current jobs status of community health workers and their potential to implement integrated approaches. This was accomplished by a desk review of nutrition and ECD policy documents, as well as interviews with key informants, community health workers, and community members. We found that Malawi has comprehensive policies and well-outlined coordination structures for nutrition and ECD that advocate for integrated approaches. Strong multidisciplinary interaction exists at central levels but not at the community level. Integration of community health workers from different sectors is limited by workload, logistics, and a lack of synchronized work schedules. Favorable, sound policies and well-outlined coordination structures alone are not enough for the establishment of integrated nutrition and ECD activities. Balanced bureaucratic structures, improved task allocation, and synchronization of work schedules across all relevant sectors are needed for integrated intervention in Malawi. © 2014 New York Academy of Sciences.

  9. Top-Down Hydrogen-Deuterium Exchange Analysis of Protein Structures Using Ultraviolet Photodissociation.

    PubMed

    Brodie, Nicholas I; Huguet, Romain; Zhang, Terry; Viner, Rosa; Zabrouskov, Vlad; Pan, Jingxi; Petrotchenko, Evgeniy V; Borchers, Christoph H

    2018-03-06

    Top-down hydrogen-deuterium exchange (HDX) analysis using electron capture or transfer dissociation Fourier transform mass spectrometry (FTMS) is a powerful method for the analysis of secondary structure of proteins in solution. The resolution of the method is a function of the degree of fragmentation of backbone bonds in the proteins. While fragmentation is usually extensive near the N- and C-termini, electron capture (ECD) or electron transfer dissociation (ETD) fragmentation methods sometimes lack good coverage of certain regions of the protein, most often in the middle of the sequence. Ultraviolet photodissociation (UVPD) is a recently developed fast-fragmentation technique, which provides extensive backbone fragmentation that can be complementary in sequence coverage to the aforementioned electron-based fragmentation techniques. Here, we explore the application of electrospray ionization (ESI)-UVPD FTMS on an Orbitrap Fusion Lumos Tribrid mass spectrometer to top-down HDX analysis of proteins. We have incorporated UVPD-specific fragment-ion types and fragment-ion mixtures into our isotopic envelope fitting software (HDX Match) for the top-down HDX analysis. We have shown that UVPD data is complementary to ETD, thus improving the overall resolution when used as a combined approach.

  10. Development and operation of a 6LiF:ZnS(Ag)-scintillating plastic capture-gated detector

    NASA Astrophysics Data System (ADS)

    Wilhelm, K.; Nattress, J.; Jovanovic, I.

    2017-01-01

    We report on the design, construction, and operation of a capture-gated neutron detector based on a heterogeneous scintillating structure comprising two scintillator types. A flat, 500 μm thick sheet composed of a mixture of lithium-6-fluoride capture agent, 6LiF, and zinc sulfide phosphor, ZnS(Ag), is wrapped around scintillating polyvinyl toluene (PVT) in a form of cylinder. The 6LiF: ZnS(Ag) sheet uses an aluminum foil backing as a support for the scintillating material and as an optical reflector, and its optical properties have been characterized independently. The composite scintillator was tested using 252Cf, DD fusion, 137Cs, and 60Co sources. The intrinsic detection efficiency for neutrons from an unmoderated 252Cf source and rejection of gammas from 137Cs were measured to be 3.6 % and 10-6, respectively. A figure of merit for pulse shape discrimination of 4.6 was achieved, and capture-gated spectroscopic analysis is demonstrated.

  11. A Single Chiroptical Spectroscopic Method May Not Be Able To Establish the Absolute Configurations of Diastereomers: Dimethylesters of Hibiscus and Garcinia Acids

    PubMed Central

    Polavarapu, Prasad L.; Donahue, Emily A.; Shanmugam, Ganesh; Scalmani, Giovanni; Hawkins, Edward K.; Rizzo, Carmelo; Ibnusaud, Ibrahim; Thomas, Grace; Habel, Deenamma; Sebastian, Dellamol

    2013-01-01

    Electronic circular dichroism (ECD), optical rotatory dispersion (ORD), and vibrational circular dichroism (VCD) spectra of hibiscus acid dimethyl ester have been measured and analyzed in combination with quantum chemical calculations of corresponding spectra. These results, along with those reported previously for garcinia acid dimethyl ester, reveal that none of these three (ECD, ORD, or VCD) spectroscopic methods, in isolation, can unequivocally establish the absolute configurations of diastereomers. This deficiency is eliminated when a combined spectral analysis of either ECD and VCD or ORD and VCD methods is used. It is also found that the ambiguities in the assignment of absolute configurations of diastereomers may also be overcome when unpolarized vibrational absorption is included in the spectral analysis. PMID:21568330

  12. Optimization of 6LiF:ZnS(Ag) scintillator light yield using GEANT4

    NASA Astrophysics Data System (ADS)

    Yehuda-Zada, Y.; Pritchard, K.; Ziegler, J. B.; Cooksey, C.; Siebein, K.; Jackson, M.; Hurlbut, C.; Kadmon, Y.; Cohen, Y.; Ibberson, R. M.; Majkrzak, C. F.; Maliszewskyj, N. C.; Orion, I.; Osovizky, A.

    2018-06-01

    A new cold neutron detector has been developed at the NIST Center for Neutron Research (NCNR) for the CANDoR (Chromatic Analysis Neutron Diffractometer or Reflectometer) project. Geometric and performance constraints dictate that this detector be exceptionally thin (∼ 2 mm). For this reason, the design of the detector consists of a 6LiF:ZnS(Ag) scintillator with embedded wavelength shifting (WLS) fibers. We used the GEANT4 package to simulate neutron capture and light transport in the detector to optimize the composition and arrangement of materials to satisfy the competing requirements of high neutron capture probability and light production and transport. In the process, we have developed a method for predicting light collection and total neutron detection efficiency for different detector configurations. The simulation was performed by adjusting crucial parameters such as the scintillator stoichiometry, light yield, component grain size, WLS fiber geometry, and reflectors at the outside edges of the scintillator volume. Three different detector configurations were fabricated and their test results were correlated with the simulations. Through this correlation we have managed to find a common photon threshold for the different detector configurations which was then used to simulate and predict the efficiencies for many other detector configurations. New detectors that have been fabricated based on simulation results yielding the desired sensitivity of 90% for 3.27 meV (5 Å) cold neutrons. The simulation has proven to be a useful tool by dramatically reducing the development period and the required number of detector prototypes. It can be used to test new designs with different thicknesses and different target neutron energies.

  13. Method and apparatus for measuring spatial uniformity of radiation

    DOEpatents

    Field, Halden

    2002-01-01

    A method and apparatus for measuring the spatial uniformity of the intensity of a radiation beam from a radiation source based on a single sampling time and/or a single pulse of radiation. The measuring apparatus includes a plurality of radiation detectors positioned on planar mounting plate to form a radiation receiving area that has a shape and size approximating the size and shape of the cross section of the radiation beam. The detectors concurrently receive portions of the radiation beam and transmit electrical signals representative of the intensity of impinging radiation to a signal processor circuit connected to each of the detectors and adapted to concurrently receive the electrical signals from the detectors and process with a central processing unit (CPU) the signals to determine intensities of the radiation impinging at each detector location. The CPU displays the determined intensities and relative intensity values corresponding to each detector location to an operator of the measuring apparatus on an included data display device. Concurrent sampling of each detector is achieved by connecting to each detector a sample and hold circuit that is configured to track the signal and store it upon receipt of a "capture" signal. A switching device then selectively retrieves the signals and transmits the signals to the CPU through a single analog to digital (A/D) converter. The "capture" signal. is then removed from the sample-and-hold circuits. Alternatively, concurrent sampling is achieved by providing an A/D converter for each detector, each of which transmits a corresponding digital signal to the CPU. The sampling or reading of the detector signals can be controlled by the CPU or level-detection and timing circuit.

  14. Predicted performance of a PG-SPECT system using CZT primary detectors and secondary Compton-suppression anti-coincidence detectors under near-clinical settings for boron neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Hales, Brian; Katabuchi, Tatsuya; Igashira, Masayuki; Terada, Kazushi; Hayashizaki, Noriyosu; Kobayashi, Tooru

    2017-12-01

    A test version of a prompt-gamma single photon emission computed tomography (PG-SPECT) system for boron neutron capture therapy (BNCT) using a CdZnTe (CZT) semiconductor detector with a secondary BGO anti-Compton suppression detector has been designed. A phantom with healthy tissue region of pure water, and 2 tumor regions of 5 wt% borated polyethylene was irradiated to a fluence of 1.3 × 109 n/cm2. The number of 478 keV foreground, background, and net counts were measured for each detector position and angle. Using only experimentally measured net counts, an image of the 478 keV production from the 10B(n , α) 7Li* reaction was reconstructed. Using Monte Carlo simulation and the experimentally measured background counts, the reliability of the system under clinically accurate parameters was extrapolated. After extrapolation, it was found that the value of the maximum-value pixel in the reconstructed 478 keV γ-ray production image overestimates the simulated production by an average of 9.2%, and that the standard deviation associated with the same value is 11.4%.

  15. Layered semiconductor neutron detectors

    DOEpatents

    Mao, Samuel S; Perry, Dale L

    2013-12-10

    Room temperature operating solid state hand held neutron detectors integrate one or more relatively thin layers of a high neutron interaction cross-section element or materials with semiconductor detectors. The high neutron interaction cross-section element (e.g., Gd, B or Li) or materials comprising at least one high neutron interaction cross-section element can be in the form of unstructured layers or micro- or nano-structured arrays. Such architecture provides high efficiency neutron detector devices by capturing substantially more carriers produced from high energy .alpha.-particles or .gamma.-photons generated by neutron interaction.

  16. High-precision quasi-continuous atmospheric greenhouse gas measurements at Trainou tower (Orléans forest, France)

    NASA Astrophysics Data System (ADS)

    Schmidt, M.; Lopez, M.; Yver Kwok, C.; Messager, C.; Ramonet, M.; Wastine, B.; Vuillemin, C.; Truong, F.; Gal, B.; Parmentier, E.; Cloué, O.; Ciais, P.

    2014-07-01

    Results from the Trainou tall tower measurement station installed in 2006 are presented for atmospheric measurements of CO2, CH4, N2O, SF6, CO, H2 mole fractions and radon-222 activity. Air is sampled from four sampling heights (180, 100, 50 and 5 m) of the Trainou 200 m television tower in the Orléans forest in France (47°57'53" N, 2°06'45" E, 131 m a.s.l.). The station is equipped with a custom-built CO2 analyser (CARIBOU), which is based on a commercial non-dispersive, infrared (NDIR) analyser (Licor 6252), and a coupled gas chromatography (GC) system equipped with an electron capture detector (ECD) and a flame ionization detector (FID) (HP6890N, Agilent) and a reduction gas detector (PP1, Peak Performer). Air intakes, pumping and air drying system are shared between the CARIBOU and the GC systems. The ultimately achieved short-term repeatability (1 sigma, over several days) for the GC system is 0.05 ppm for CO2, 1.4 ppb for CH4, 0.25 ppb for N2O, 0.08 ppb for SF6, 0.88 ppb for CO and 3.8 for H2. The repeatability of the CARIBOU CO2 analyser is 0.06 ppm. In addition to the in situ measurements, weekly flask sampling is performed, and flask air samples are analysed at the Laboratoire des Sciences du Climat et de l'Environnement (LSCE) central laboratory for the same species as well for stable isotopes of CO2. The comparison between in situ measurements and the flask sampling showed averaged differences of 0.08 ± 1.40 ppm for CO2, 0.7 ± 7.3 ppb for CH4, 0.6 ± 0.6 ppb for N2O, 0.01 ± 0.10 ppt for SF6, 1.5± 5.3 ppb for CO and 4.8± 6.9 ppb for H2 for the years 2008-2012. At Trainou station, the mean annual increase rates from 2007 to 2011 at the 180 m sampling height were 2.2 ppm yr-1 for CO2, 4 ppb yr-1 for CH4, 0.78 ppb yr-1 for N2O and 0.29 ppt yr-1 for SF6. For all species, the 180 m sampling level showed the smallest diurnal variation. Mean diurnal gradients between the 50 m and the 180 m sampling level reached up to 30 ppm CO2, 15 ppm CH4 or 0.5 ppb N2O during nighttime whereas the mean gradients are smaller than 0.5 ppm for CO2 and 1.5 ppb for CH4 during afternoon.

  17. Expanded criteria donor kidneys for younger recipients: acceptable outcomes.

    PubMed

    Goplani, K R; Kute, V B; Vanikar, A V; Shah, P R; Gumber, M R; Patel, H V; Modi, P R; Trivedi, H L

    2010-12-01

    European senior programme (ESP) is well known for acceptable outcomes using expanded criteria donor (ECD) kidneys from donors older than 65 years for recipients older than 65 years. The incidence of end-stage renal disease (ESRD) is 229/million in India with a mean age of 45 years. We performed a retrospective analysis of transplantation of ECD versus standard criteria donor (SCD) kidneys into younger recipients. Forty-three ECD transplantations among 158 deceased donor organ transplantation (DDOT) were performed between January 2006 and December 2009. Among 43 transplantation from 30 donors, 14 were dual kidney transplantations (DKT) performed based upon biopsy evaluation. All recipients received thymoglobulin (rATG) induction followed by immunosuppression with a steroid, mycophenolate mofetil (MMF), and a calcineurin inhibitor. Statistical analysis used chi-square test and unpaired Student t test. Kaplan-Meier curves were used for survival analysis. For ECD the mean donor age was 64 ± 11 years. Cerebrovascular accidents (CVA) were the cause of death among 60% of donors, 73.13% of whom were hypertensive and 23.13% diabetic. Mean DKT donor age was 75 ± 9.17 years versus 60 ± 8.0 years for single kidney transplantation (SKT). Mean recipient age of DKT versus SKT was 44 ± 12.4 years versus 43 ± 14 years. Mean serum creatinine (SCr; mg/dL) of SKT patients was 1.64 ± 0.75 versus 1.68 ± 0.46 in DKT. Mean follow-up was 455 ± 352 days. Mean SCr of 43 ECD recipients of mean age, 43.4 ± 14.2 years was 1.61 ± 0.61 mg/dL. Among 43 recipients, 23.25% were diabetic, 41.86% displayed delayed graft function (DGF), and 23.25% experienced biopsy-proven acute rejection (BPAR). Patient survival rate was 72.09% and graft survival rate was 67.44%. For SCD transplantations (n = 115), the mean donor age was 36 ± 14 years and recipient mean age was 32.8 ± 14.07 years. Mean SCr was 1.32 ± 0.46 mg/dL with 26.95% recipients displaying DGF, whereas 20.86% had BPAR. In the SCD group the patient survival rate was 79.13% and the graft survival rate was 72.17%. Thus, although the ECD group showed poor graft function (P = .042), they had acceptable patient and graft survivals (P = .34 and P = .56, respectively). Because of the organ shortage, DDOT using ECD transplants for younger recipients is a feasible option with acceptable outcomes. Copyright © 2010 Elsevier Inc. All rights reserved.

  18. The impact of meeting donor management goals on the number of organs transplanted per expanded criteria donor: a prospective study from the UNOS Region 5 Donor Management Goals Workgroup.

    PubMed

    Patel, Madhukar S; Zatarain, John; De La Cruz, Salvador; Sally, Mitchell B; Ewing, Tyler; Crutchfield, Megan; Enestvedt, C Kristian; Malinoski, Darren J

    2014-09-01

    The shortage of organs available for transplant has led to the use of expanded criteria donors (ECDs) to extend the donor pool. These donors are older and have more comorbidities and efforts to optimize the quality of their organs are needed. To determine the impact of meeting a standardized set of critical care end points, or donor management goals (DMGs), on the number of organs transplanted per donor in ECDs. Prospective interventional study from February 2010 to July 2013 of all ECDs managed by the 8 organ procurement organizations in the southwestern United States (United Network for Organ Sharing Region 5). Implementation of 9 DMGs as a checklist to guide the management of every ECD. The DMGs represented normal cardiovascular, pulmonary, renal, and endocrine end points. Meeting the DMG bundle was defined a priori as achieving any 7 of the 9 end points and was recorded at the time of referral to the organ procurement organization, at the time of authorization for donation, 12 to 18 hours later, and prior to organ recovery. The primary outcome measure was 3 or more organs transplanted per donor and binary logistic regression was used to identify independent predictors with P < .05. There were 671 ECDs with a mean (SD) number of 2.1 (1.3) organs transplanted per donor. Ten percent of the ECDs had met the DMG bundle at referral, 15% at the time of authorization, 33% at 12 to 18 hours, and 45% prior to recovery. Forty-three percent had 3 or more organs transplanted per donor. Independent predictors of 3 or more organs transplanted per donor were older age (odds ratio [OR] = 0.95 per year [95% CI, 0.93-0.97]), increased creatinine level (OR = 0.73 per mg/dL [95% CI, 0.63-0.85]), DMGs met prior to organ recovery (OR = 1.90 [95% CI, 1.35-2.68]), and a change in the number of DMGs achieved from referral to organ recovery (OR = 1.11 per additional DMG [95% CI, 1.00-1.23]). Meeting DMGs prior to organ recovery with ECDs is associated with achieving 3 or more organs transplanted per donor. An increase in the number of critical care end points achieved throughout the care of a potential donor by both donor hospital and organ procurement organization is also associated with an increase in organ yield.

  19. (n,{gamma}) Experiments on tin isotopes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baramsai, B.; Mitchell, G. E.; Walker, C. L.

    2013-04-19

    Neutron capture experiments on highly enriched {sup 117,119}Sn isotopes were performed with the DANCE detector array located at the Los Alamos Neutron Science Center. The DANCE detector provides detailed information about the multi-step {gamma}-ray cascade following neutron capture. Analysis of the experimental data provides important information to improve understanding of the neutron capture reaction, including a test of the statistical model, the assignment of spins and parities of neutron resonances, and information concerning the Photon Strength Function (PSF) and Level Density (LD) below the neutron separation energy. Preliminary results for the (n,{gamma}) reaction on {sup 117,119}Sn are presented. Resonance spinsmore » of the odd-A tin isotopes were almost completely unknown. Resonance spins and parities have been assigned via analysis of the multi-step {gamma}-ray spectra and directional correlations.« less

  20. Our Children...Today's Investment, Tomorrow's Promise. Building an Early Childhood Development System for Nova Scotia.

    ERIC Educational Resources Information Center

    2001

    This report provides the framework for response to Nova Scotia's agreement with the government of Canada to invest in an early childhood development (ECD) strategy. The report begins with a list of guiding principles for child and family services. The major challenge for the ECD strategy is to identify the key areas of investment that will create…

  1. An Assessment of Nutritional Patterns in Early Childhood Centres in Zimbabwe: A Quest for Dietary Quality

    ERIC Educational Resources Information Center

    Runyowa, Julius; Podzo, Barbara Zvisinei; Kanyume, Patience

    2014-01-01

    The study explored the experiences of ECD centres in Masvingo district in terms of the quality of meals with regards to diversity and size of portions and WASH provisions. One school was purposively sampled. The research adopted a qualitative paradigm and used one ECD centre in Masvingo district as a case study. Data were gathered through…

  2. Determination of Nitroaromatic, Nitramine, and Nitrate Ester Explosives in Soils Using GC-ECD

    DTIC Science & Technology

    1999-08-01

    for supplying soils from minefields; and Dr. Paul H. Miyares, CRREL, for HPLC analysis of Fort Leonard Wood soil extracts. ii CONTENTS P reface...42 ILLUSTRATIONS Figure 1. Correlation analysis of GC-ECD concentration (mg/kg) estimates with those from HPLC -UV...kg) estimates with those from HPLC -UV analysis using splits of the same acetonitrile extract from archived soils

  3. Metallocorroles as inherently chiral chromophores: resolution and electronic circular dichroism spectroscopy of a tungsten biscorrole.

    PubMed

    Schies, Christine; Alemayehu, Abraham B; Vazquez-Lima, Hugo; Thomas, Kolle E; Bruhn, Torsten; Bringmann, Gerhard; Ghosh, Abhik

    2017-06-01

    An inherently chiral metallocorrole has been resolved for the first time by means of HPLC on a chiral stationary phase. For the compound in question, a homoleptic tungsten biscorrole, the absolute configurations of the enantiomers were assigned using online HPLC-ECD measurements in conjunction with time-dependent CAM-B3LYP calculations, which provided accurate simulations of the ECD spectra.

  4. Predictors and Pathways of Language and Motor Development in Four Prospective Cohorts of Young Children in Ghana, Malawi, and Burkina Faso

    ERIC Educational Resources Information Center

    Prado, Elizabeth L.; Abbeddou, Souheila; Adu-Afarwuah, Seth; Arimond, Mary; Ashorn, Per; Ashorn, Ulla; Bendabenda, Jaden; Brown, Kenneth H.; Hess, Sonja Y.; Kortekangas, Emma; Lartey, Anna; Maleta, Kenneth; Oaks, Brietta M.; Ocansey, Eugenia; Okronipa, Harriet; Ouédraogo, Jean Bosco; Pulakka, Anna; Somé, Jérôme W.; Stewart, Christine P.; Stewart, Robert C.; Vosti, Stephen A.; Yakes Jimenez, Elizabeth; Dewey, Kathryn G.

    2017-01-01

    Background: Previous reviews have identified 44 risk factors for poor early child development (ECD) in low- and middle-income countries. Further understanding of their relative influence and pathways is needed to inform the design of interventions targeting ECD. Methods: We conducted path analyses of factors associated with 18-month language and…

  5. From Early Child Development to Human Development: Investing in Our Children's Future. Proceedings of a World Bank Conference (Washington, D.C., April 10-11, 2000).

    ERIC Educational Resources Information Center

    Young, Mary Eming, Ed.

    In April 2000, the World Bank hosted a global conference that addressed the benefits and challenges of investing in early child development (ECD). The landmark conference brought together the world's leading experts, academicians, practitioners, and policymakers to focus on various aspects of ECD. This volume contains the proceedings of the…

  6. 77 FR 20321 - Airworthiness Directives; Eurocopter Deutschland GmbH Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-04

    ... Deutschland GmbH Helicopters AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed... Deutschland GmbH (ECD) MBB-BK 117 A-3, MBB-BK 117 A-4, MBB- BK B-1, MBB-BK 117 B-2, and MBB-BK C-1 helicopters... Eurocopter Deutschland GmbH (ECD) Model MBB-BK 117 A-4 model. The EASA AD makes no mention of this model. The...

  7. The Relationship between Gross Motor Skills and School Readiness in Early Childhood: Making the Case in South Africa

    ERIC Educational Resources Information Center

    Sherry, Kate; Draper, Catherine E.

    2013-01-01

    Early childhood development (ECD) has gained substantial recognition in South Africa (SA) as a key issue to be addressed, but inequities and deficits remain evident, despite progressive policy and widespread effort by a range of role players in the non-governmental sector. ECD in SA requires far more attention if these are to be rectified, and…

  8. Hypothermic oxygenated machine perfusion (HOPE) for orthotopic liver transplantation of human liver allografts from extended criteria donors (ECD) in donation after brain death (DBD): a prospective multicentre randomised controlled trial (HOPE ECD-DBD).

    PubMed

    Czigany, Zoltan; Schöning, Wenzel; Ulmer, Tom Florian; Bednarsch, Jan; Amygdalos, Iakovos; Cramer, Thorsten; Rogiers, Xavier; Popescu, Irinel; Botea, Florin; Froněk, Jiří; Kroy, Daniela; Koch, Alexander; Tacke, Frank; Trautwein, Christian; Tolba, Rene H; Hein, Marc; Koek, Ger H; Dejong, Cornelis H C; Neumann, Ulf Peter; Lurje, Georg

    2017-10-10

    Orthotopic liver transplantation (OLT) has emerged as the mainstay of treatment for end-stage liver disease. In an attempt to improve the availability of donor allografts and reduce waiting list mortality, graft acceptance criteria were extended increasingly over the decades. The use of extended criteria donor (ECD) allografts is associated with a higher incidence of primary graft non-function and/or delayed graft function. As such, several strategies have been developed aiming at reconditioning poor quality ECD liver allografts. Hypothermic oxygenated machine perfusion (HOPE) has been successfully tested in preclinical experiments and in few clinical series of donation after cardiac death OLT. HOPE ECD-DBD is an investigator-initiated, open-label, phase-II, prospective multicentre randomised controlled trial on the effects of HOPE on ECD allografts in donation after brain death (DBD) OLT. Human whole organ liver grafts will be submitted to 1-2 hours of HOPE (n=23) via the portal vein before implantation and are going to be compared with a control group (n=23) of patients transplanted after conventional cold storage. Primary (peak and Δ peak alanine aminotransferase within 7 days) and secondary (aspartate aminotransferase, bilirubin and international normalised ratio, postoperative complications, early allograft dysfunction, duration of hospital and intensive care unit stay, 1-year patient and graft survival) endpoints will be analysed within a 12-month follow-up. Extent of ischaemia-reperfusion (I/R) injury will be assessed using liver tissue, perfusate, bile and serum samples taken during the perioperative phase of OLT. The study was approved by the institutional review board of the RWTH Aachen University, Aachen, Germany (EK 049/17). The current paper represent the pre-results phase. First results are expected in 2018. NCT03124641. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. The role of glutamic or aspartic acid in position four of the epitope binding motif and thyrotropin receptor-extracellular domain epitope selection in Graves' disease.

    PubMed

    Inaba, Hidefumi; Martin, William; Ardito, Matt; De Groot, Anne Searls; De Groot, Leslie J

    2010-06-01

    Development of Graves' disease (GD) is related to HLA-DRB1*0301 (DR3),and more specifically to arginine at position 74 of the DRB1 molecule. The extracellular domain (ECD) of human TSH receptor (hTSH-R) contains the target antigen. We analyzed the relation between hTSH-R-ECD peptides and DR molecules to determine whether aspartic acid (D) or glutamic acid (E) at position four in the binding motif influenced selection of functional epitopes. Peptide epitopes from TSH-R-ECD with D or E in position four (D/E+) had higher affinity for binding to DR3 than peptides without D/E (D/E-) (IC(50) 29.3 vs. 61.4, P = 0.0024). HLA-DR7, negatively correlated with GD, and DRB1*0302 (HLA-DR18), not associated with GD, had different profiles of epitope binding. Toxic GD patients who are DR3+ had higher responses to D/E+ peptides than D/E- peptides (stimulation index 1.42 vs. 1.22, P = 0.028). All DR3+ GD patients (toxic + euthyroid) had higher responses, with borderline significance (Sl; 1.32 vs. 1.18, P = 0.051). Splenocytes of DR3 transgenic mice immunized to TSH-R-ECD responded to D/E+ peptides more than D/E- peptides (stimulation index 1.95 vs. 1.69, P = 0.036). Seven of nine hTSH-R-ECD peptide epitopes reported to be reactive with GD patients' peripheral blood mononuclear cells contain binding motifs with D/E at position four. TSH-R-ECD epitopes with D/E in position four of the binding motif bind more strongly to DRB1*0301 than epitopes that are D/E- and are more stimulatory to GD patients' peripheral blood mononuclear cells and to splenocytes from mice immunized to hTSH-R. These epitopes appear important in immunogenicity to TSH-R due to their favored binding to HLA-DR3, thus increasing presentation to T cells.

  10. Early clinical experience utilizing scintillator with optical fiber (SOF) detector in clinical boron neutron capture therapy: its issues and solutions.

    PubMed

    Ishikawa, Masayori; Yamamoto, Tetsuya; Matsumura, Akira; Hiratsuka, Junichi; Miyatake, Shin-Ichi; Kato, Itsuro; Sakurai, Yoshinori; Kumada, Hiroaki; Shrestha, Shubhechha J; Ono, Koji

    2016-08-09

    Real-time measurement of thermal neutrons in the tumor region is essential for proper evaluation of the absorbed dose in boron neutron capture therapy (BNCT) treatment. The gold wire activation method has been routinely used to measure the neutron flux distribution in BNCT irradiation, but a real-time measurement using gold wire is not possible. To overcome this issue, the scintillator with optical fiber (SOF) detector has been developed. The purpose of this study is to demonstrate the feasibility of the SOF detector as a real-time thermal neutron monitor in clinical BNCT treatment and also to report issues in the use of SOF detectors in clinical practice and their solutions. Clinical measurements using the SOF detector were carried out in 16 BNCT clinical trial patients from December 2002 until end of 2006 at the Japanese Atomic Energy Agency (JAEA) and Kyoto University Research Reactor Institute (KURRI). The SOF detector worked effectively as a real-time thermal neutron monitor. The neutron fluence obtained by the gold wire activation method was found to differ from that obtained by the SOF detector. The neutron fluence obtained by the SOF detector was in better agreement with the expected fluence than with gold wire activation. The estimation error for the SOF detector was small in comparison to the gold wire measurement. In addition, real-time monitoring suggested that the neutron flux distribution and intensity at the region of interest (ROI) may vary due to the reactor condition, patient motion and dislocation of the SOF detector. Clinical measurements using the SOF detector to measure thermal neutron flux during BNCT confirmed that SOF detectors are effective as a real-time thermal neutron monitor. To minimize the estimation error due to the displacement of the SOF probe during treatment, a loop-type SOF probe was developed.

  11. 3D chiral nanoplasmonics: fabrication, chiroptic engineering, mechanism, and application in enantioselection (Presentation Recording)

    NASA Astrophysics Data System (ADS)

    Huang, Zhifeng

    2015-09-01

    Chirality does naturally exist, and the building blocks of life (e.g. DNA, proteins, peptides and sugars) are usually chiral. Chirality inherently imposes chemical/biological selectivity on functional molecules; hence the discrimination in molecular chirality from an enantiomer to the other mirror image (i.e. enantioselection) has fundamental and application significance. Enantiomers interact with left and right handed circularly polarized light in a different manner with respect to optical extinction; hence, electronic circular dichroism (ECD) has been widely used for enantioselection. However, enantiomers usually have remarkably low ECD intensity, mainly owing to the small electric transition dipole moment induced by molecular sizes compared to the ECD-active wavelength in the UV-visible-near IR region. To enhance ECD magnitude, recently it has being developed 3D chiral nanoplasmonic structures having a helical path, and the dimensions are comparable to the ECD wavelength. However, it is still ambiguous the origin of 3D chiroplasmonics, and there is a lack of studying the interaction of 3D chiroplasmoncs with enantiomers for the application of enantioselection. Herein, we will present a one-step fabrication of 3D silver nanospirals (AgNSs) via low-substrate-temperature glancing angle deposition. AgNSs can be deposited on a wide range of substrates (including transparent and flexible substrates), in an area on the order of cm2. A set of spiral dimensions (such as spiral pitches, number of turns and handedness) have been easily engineered to tune the chiroptic properties, leading to studying the chiroplasmonic principles together with finite element simulation and the LC model. At the end, it will be demonstrated that 3D chiroplasmonics can differentiate molecular chirality of enantiomers with dramatic enhancement in the anisotropy g factor. This study opens a door to sensitively discriminate enantiomer chirality.

  12. Clinical considerations and key issues in the management of patients with Erdheim-Chester Disease: a seven case series.

    PubMed

    Mazor, Roei D; Manevich-Mazor, Mirra; Kesler, Anat; Aizenstein, Orna; Eshed, Iris; Jaffe, Ronald; Pessach, Yakov; Goldberg, Ilan; Sprecher, Eli; Yaish, Iris; Gural, Alexander; Ganzel, Chezi; Shoenfeld, Yehuda

    2014-12-01

    Erdheim-Chester Disease (ECD), a non Langerhans' cell histiocytosis of orphan nature and propensity for multi-systemic presentations, comprises an intricate medical challenge in terms of diagnosis, treatment and complication management. The objectives are to report the clinical, radiological and pathological characteristics, as well as cardinal therapeutic approaches to ECD patients and to provide clinical analyses of the medical chronicles of these complex patients. Patients with biopsy proven ECD were audited by a multi-disciplinary team of specialists who formed a coherent timeline of all the substantial clinical events in the evolution of their patients' illness. Seven patients (five men, two women) were recruited to the study. The median age at presentation was 53 years (range: 39 to 62 years). The median follow-up time was 36 months (range: 1 to 72 months). Notable ECD involvement sites included the skeleton (seven), pituitary gland (seven), retroperitoneum (five), central nervous system (four), skin (four), lungs and pleura (four), orbits (three), heart and great vessels (three) and retinae (one). Prominent signs and symptoms were fever (seven), polyuria and polydipsia (six), ataxia and dysarthria (four), bone pain (four), exophthalmos (three), renovascular hypertension (one) and dyspnea (one). The V600E BRAF mutation was verified in three of six patients tested. Interferon-α treatment was beneficial in three of six patients treated. Vemurafenib yielded dramatic neurological improvement in a BRAF mutated patient. Infliximab facilitated pericardial effusion volume reduction. Cladribine improved cerebral blood flow originally compromised by perivenous lesions. ECD is a complex, multi-systemic, clonal entity coalescing both neoplastic and inflammatory elements and strongly dependent on impaired RAS/RAF/MEK/ERK signaling.

  13. Effect of glaucoma tube shunt parameters on cornea endothelial cells in patients with Ahmed valve implants.

    PubMed

    Koo, Euna B; Hou, Jing; Han, Ying; Keenan, Jeremy D; Stamper, Robert L; Jeng, Bennie H

    2015-01-01

    The aim of this study was to assess the effect of various tube parameters on corneal endothelial cell density (ECD) after insertion of Ahmed valves. Thirty-nine eyes of 33 patients with previous superotemporal (ST) Ahmed valve implantation and 20 eyes of 13 participants with previous uncomplicated phacoemulsification and intraocular lens implantation but no history of glaucoma surgery were evaluated. Various tube parameters were measured with anterior segment optical coherence tomography. ST, central, and inferonasal (IN) ECD and pachymetry were measured. Endothelial cell loss and corneal thickness in the ST cornea was compared with those in the IN cornea. The mean age of the operated patients was 58 ± 22 years, and the mean time since glaucoma surgery was 2.5 ± 2.6 years. Thirty-two of the 39 study eyes were pseudophakic. The ECD was significantly lower in the ST endothelium than in the IN endothelium in eyes with glaucoma tube surgery (P < 0.001), although this relative reduction in ST ECD was not greater than that seen in pseudophakic control eyes (P = 0.16). In univariate analysis, tube angle relative to the cornea and distance from the tip of the tube to the cornea were significant risk factors for decreased ST endothelial cell loss when assessed relative to the IN ECD (P = 0.01 and P = 0.02, respectively). In multivariate analysis, only the distance of the tube tip to the cornea remained significantly associated with ST endothelial cell loss. Although this was a retrospective study with inherent limitations, tubes that are closer to the cornea seem to lead to increased loss of adjacent endothelial cells.

  14. Improved methodology to obtain large quantities of correctly folded recombinant N-terminal extracellular domain of the human muscle acetylcholine receptor for inducing experimental autoimmune myasthenia gravis in rats

    PubMed Central

    Sun, Chenjing; Zhang, Hongliang; Xu, Jiang; Gao, Jie

    2013-01-01

    Introduction Human myasthenia gravis (MG) is an autoimmune disorder of the neuromuscular system. Experimental autoimmune myasthenia gravis (EAMG) is a well-established animal model for MG that can be induced by active immunization with the Torpedo californica-derived acetylcholine receptor (AChR). Due to the expensive cost of purifying AChR from Torpedo californica, the development of an easier and more economical way of inducing EAMG remains critically needed. Material and methods Full-length cDNA of the human skeletal muscle AChR α1 subunit was obtained from TE671 cells. The DNA fragment encoding the extracellular domain (ECD) was then amplified by polymerase chain reaction (PCR) and inserted into pET-16b. The reconstructed plasmid was transformed into the host strain BL21(DE3)pLysS, which was derived from Escherichia coli. Isopropyl-β-D-thiogalactopyranoside (IPTG) was used to induce the expression of the N-terminal ECD. The produced protein was purified with immobilized Ni2+ affinity chromatography and refolded by dialysis. Results The recombinant protein was efficiently refolded to soluble active protein, which was verified by ELISA. After immunization with the recombinant ECD, all rats acquired clinical signs of EAMG. The titer of AChR antibodies in the serum was significantly higher in the EAMG group than in the control group, indicating successful induction of EAMG. Conclusions We describe an improved procedure for refolding recombinant ECD of human muscle AChR. This improvement allows for the generation of large quantities of correctly folded recombinant ECD of human muscle AChR, which provides for an easier and more economical way of inducing the animal model of MG. PMID:24904677

  15. Chemicals on plant surfaces as a heretofore unrecognized, but ecologically informative, class for investigations into plant defence.

    PubMed

    LoPresti, Eric F

    2016-11-01

    Plants produce and utilize a great diversity of chemicals for a variety of physiological and ecological purposes. Many of these chemicals defend plants against herbivores, pathogens and competitors. The location of these chemicals varies within the plant, some are located entirely within plant tissues, others exist in the air- (or water-) space around plants, and still others are secreted onto plant surfaces as exudates. I argue herein that the location of a given defensive chemical has profound implications for its ecological function; specifically, I focus on the characteristics of chemical defences secreted onto plant surfaces. Drawing from a broad literature encompassing ecology, evolution, taxonomy and physiology, I found that these external chemical defences (ECDs) are common and widespread in plants and algae; hundreds of examples have been detailed, yet they are not delineated as a separate class from internal chemical defences (ICDs). I propose a novel typology for ECDs and, using existing literature, explore the ecological consequences of the hypothesized unique characteristics of ECDs. The axis of total or proportional investment in ECDs versus ICDs should be considered as one axis of investment by a plant, in the same way as quantitative versus qualitative chemical defences or induced versus constitutive defences is considered. The ease of manipulating ECDs in many plant systems presents a powerful tool to help test plant defence theory (e.g. optimal defence). The framework outlined here integrates various disciplines of botany and ecology and suggests a need for further examinations of exudates in a variety of contexts, as well as recognition of the effects of within-plant localization of defences. © 2015 Cambridge Philosophical Society.

  16. Comparison of endothelial cell density of organ cultured corneas with cornea donor study.

    PubMed

    Campolmi, Nelly; He, Zhiguo; Acquart, Sophie; Trone, Marie-Caroline; Bernard, Aurélien; Gauthier, Anne-Sophie; Garraud, Olivier; Forest, Fabien; Péocʼh, Michel; Gain, Philippe; Thuret, Gilles

    2014-06-01

    Determination of the endothelial cell density (ECD) by eye banks is paramount in donor cornea qualification. Unbiased measurement avoids wastage and grafts with an increased risk of premature failure. Internal calibration of the counting method is essential, but external validation would add an extra stage in the assessment of reliability. In this respect, data published by the multicenter Cornea Donor Study (CDS) in 2005 is a reference. The aim of the study was to compare ECD determined within a single eye bank, which uses calibrated image analysis software designed for transmitted light microscopy images of organ cultured corneas, with the CDS data determined on specular microscopy images of corneas stored at 4°C. ECD of consecutive corneas retrieved between 2005 and 2013 was determined after exposure to 0.9% NaCl. More than 300 ECs were counted on 3 fields of the central 8 mm. Endothelial cell boundaries were automatically drawn and verified by a skilled technician who performed all necessary corrections. Three thousand fifty-two corneas were analyzed, of which 48.5% donors were >75 years (CDS upper age limit). Between 10 and 75 years, the ECD varied according to donor age exactly in the same manner as in the CDS, but were consistently higher of 100 ± 25 cells per square millimeter (P < 0.001). ECD determined by a computer-aided method from transmitted light microscopy images compares favorably with the American CDS reference series. The slight systematic difference on either side of the Atlantic Ocean could be due to (1) differences in counting principles and/or (2) higher shrinkage of the cornea caused by stromal edema in organ culture.

  17. Optimal Utilization of Donor Grafts With Extended Criteria

    PubMed Central

    Cameron, Andrew M.; Ghobrial, R Mark; Yersiz, Hasan; Farmer, Douglas G.; Lipshutz, Gerald S.; Gordon, Sherilyn A.; Zimmerman, Michael; Hong, Johnny; Collins, Thomas E.; Gornbein, Jeffery; Amersi, Farin; Weaver, Michael; Cao, Carlos; Chen, Tony; Hiatt, Jonathan R.; Busuttil, Ronald W.

    2006-01-01

    Objective: Severely limited organ resources mandate maximum utilization of donor allografts for orthotopic liver transplantation (OLT). This work aimed to identify factors that impact survival outcomes for extended criteria donors (ECD) and developed an ECD scoring system to facilitate graft-recipient matching and optimize utilization of ECDs. Methods: Retrospective analysis of over 1000 primary adult OLTs at UCLA. Extended criteria (EC) considered included donor age (>55 years), donor hospital stay (>5 days), cold ischemia time (>10 hours), and warm ischemia time (>40 minutes). One point was assigned for each extended criterion. Cox proportional hazard regression model was used for multivariate analysis. Results: Of 1153 allografts considered in the study, 568 organs exhibited no extended criteria (0 score), while 429, 135 and 21 donor allografts exhibited an EC score of 1, 2 and 3, respectively. Overall 1-year patient survival rates were 88%, 82%, 77% and 48% for recipients with EC scores of 0, 1, 2 and 3 respectively (P < 0.001). Adjusting for recipient age and urgency at the time of transplantation, multivariate analysis identified an ascending mortality risk ratio of 1.4 and 1.8 compared to a score of 0 for an EC score of 1, and 2 (P < 0.01) respectively. In contrast, an EC score of 3 was associated with a mortality risk ratio of 4.5 (P < 0.001). Further, advanced recipient age linearly increased the death hazard ratio, while an urgent recipient status increased the risk ratio of death by 50%. Conclusions: Extended criteria donors can be scored using readily available parameters. Optimizing perioperative variables and matching ECD allografts to appropriately selected recipients are crucial to maintain acceptable outcomes and represent a preferable alternative to both high waiting list mortality and to a potentially futile transplant that utilizes an ECD for a critically ill recipient. PMID:16772778

  18. Employing the FITT framework to explore HIV case managers' perceptions of two electronic clinical data (ECD) summary systems.

    PubMed

    Schnall, Rebecca; Smith, Ann B; Sikka, Manik; Gordon, Peter; Camhi, Eli; Kanter, Timothy; Bakken, Suzanne

    2012-10-01

    Case managers facilitate continuity of care for persons living with HIV (PLWH) by coordination of resources and referrals to social services and medical care. The complexity of HIV care and associated comorbidities drives the need for medical and psychosocial care coordination, which may be achieved through health information exchange (HIE) systems. However, the use of HIE has not been well studied in the context of HIV services. The purpose of this descriptive qualitative study is to explore factors influencing case managers' adoption of electronic clinical data (ECD) summaries as an HIE strategy in HIV care through application of the "fit between individuals, task and technology" (FITT) framework. Focus group methodology was used to gather perceptions from 48 participants who provided direct case management services for PLWH in New York City. Questions addressed current quality and efficiency challenges to HIE utilization in the context of case management of PLWH as well as barriers and enablers to use of an ECD summary. Analysis of the data was guided by the FITT framework. Major themes by interaction type were: (1) task-technology fit - resources, time and workflow; (2) individual-task fit - training and technical support; and 3) individual-technology fit - ECD summary functionality, technical difficulties and the need of a computer for each end-user. Our findings provide evidence for the applicability of the FITT framework to explore case managers' perceptions of factors influencing the adoption of ECD summary systems for HIV care prior to actual implementation. Assessment of fit among individual, task, and technology and addressing the concerns identified prior to implementation is critical to successful adoption of health information technology as a strategy to improve quality and efficiency in health care. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. Ultrahigh-frame CCD imagers

    NASA Astrophysics Data System (ADS)

    Lowrance, John L.; Mastrocola, V. J.; Renda, George F.; Swain, Pradyumna K.; Kabra, R.; Bhaskaran, Mahalingham; Tower, John R.; Levine, Peter A.

    2004-02-01

    This paper describes the architecture, process technology, and performance of a family of high burst rate CCDs. These imagers employ high speed, low lag photo-detectors with local storage at each photo-detector to achieve image capture at rates greater than 106 frames per second. One imager has a 64 x 64 pixel array with 12 frames of storage. A second imager has a 80 x 160 array with 28 frames of storage, and the third imager has a 64 x 64 pixel array with 300 frames of storage. Application areas include capture of rapid mechanical motion, optical wavefront sensing, fluid cavitation research, combustion studies, plasma research and wind-tunnel-based gas dynamics research.

  20. Commissioning of the NPDGamma Detector Array: Counting Statistics in Current Mode Operation and Parity Violation in the Capture of Cold Neutrons on B 4 C and (27) Al.

    PubMed

    Gericke, M T; Bowman, J D; Carlini, R D; Chupp, T E; Coulter, K P; Dabaghyan, M; Desai, D; Freedman, S J; Gentile, T R; Gillis, R C; Greene, G L; Hersman, F W; Ino, T; Ishimoto, S; Jones, G L; Lauss, B; Leuschner, M B; Losowski, B; Mahurin, R; Masuda, Y; Mitchell, G S; Muto, S; Nann, H; Page, S A; Penttila, S I; Ramsay, W D; Santra, S; Seo, P-N; Sharapov, E I; Smith, T B; Snow, W M; Wilburn, W S; Yuan, V; Zhu, H

    2005-01-01

    The NPDGamma γ-ray detector has been built to measure, with high accuracy, the size of the small parity-violating asymmetry in the angular distribution of gamma rays from the capture of polarized cold neutrons by protons. The high cold neutron flux at the Los Alamos Neutron Scattering Center (LANSCE) spallation neutron source and control of systematic errors require the use of current mode detection with vacuum photodiodes and low-noise solid-state preamplifiers. We show that the detector array operates at counting statistics and that the asymmetries due to B4C and (27)Al are zero to with- in 2 × 10(-6) and 7 × 10(-7), respectively. Boron and aluminum are used throughout the experiment. The results presented here are preliminary.

  1. FAST NEUTRON SPECTROMETER USING SPACED SEMICONDUCTORS FOR MEASURING TOTAL ENERGY OF NEUTRONS CAPTURED

    DOEpatents

    Love, T.A.; Murray, R.B.

    1964-04-14

    A fast neutron spectrometer was designed, which utilizes a pair of opposed detectors having a layer of /sup 6/LiF between to produce alpha and T pair for each neutron captured to provide signals, which, when combined, constitute a measure of neutron energy. (AEC)

  2. Electroencephalography in ellipsoidal geometry with fourth-order harmonics.

    PubMed

    Alcocer-Sosa, M; Gutierrez, D

    2016-08-01

    We present a solution to the electroencephalographs (EEG) forward problem of computing the scalp electric potentials for the case when the head's geometry is modeled using a four-shell ellipsoidal geometry and the brain sources with an equivalent current dipole (ECD). The proposed solution includes terms up to the fourth-order ellipsoidal harmonics and we compare this new approximation against those that only considered up to second- and third-order harmonics. Our comparisons use as reference a solution in which a tessellated volume approximates the head and the forward problem is solved through the boundary element method (BEM). We also assess the solution to the inverse problem of estimating the magnitude of an ECD through different harmonic approximations. Our results show that the fourth-order solution provides a better estimate of the ECD in comparison to lesser order ones.

  3. Muon capture on light isotopes in Double Chooz

    NASA Astrophysics Data System (ADS)

    Strait, M.; Double Chooz Collaboration

    2017-09-01

    Using the Double Chooz reactor neutrino detector, we have measured the products of µ - capture on 12C, 13C, 14N and 16O. Over a period of 490 days, we collected 2.3 × 106 stopping cosmic µ -, of which 1.8 × 105 captured on these nuclei in the inner detector. The resulting isotopes were tagged using prompt neutron emission (when applicable), the subsequent beta decays, and, in some cases, β-delayed neutrons. Production of these βn isotopes, primarily 9Li, which are {{{ν _e}} \\over {{ν _μ }}} backgrounds, was found at a significance of 5.5σ. The probability of 9Li production per capture on natC is (2.4 ± 0.9(stat) ± 0.1(syst)) × 10-4. We have made the most precise measurement of the rate of 12C(µ -, ν)12B to date, 6.57 - 0.21 + 0.11 × {10^3}{{ }}{{{s}} - 1},{{ or }}≤ft( {17.35 - 0.59 + 0.35} \\right)% of nuclear captures. By tagging excited states emitting gammas, the ground state transition rate to 12B is found to be 5.68 - 0.23 + 0.14 × {10^3}{{ }}{{{s}} - 1}.

  4. MEMS/ECD Method for Making Bi(2-x)Sb(x)Te3 Thermoelectric Devices

    NASA Technical Reports Server (NTRS)

    Lim, James; Huang, Chen-Kuo; Ryan, Margaret; Snyder, G. Jeffrey; Herman, Jennifer; Fleurial, Jean-Pierre

    2008-01-01

    A method of fabricating Bi(2-x)Sb(x)Te3-based thermoelectric microdevices involves a combination of (1) techniques used previously in the fabrication of integrated circuits and of microelectromechanical systems (MEMS) and (2) a relatively inexpensive MEMS-oriented electrochemical-deposition (ECD) technique. The present method overcomes the limitations of prior MEMS fabrication techniques and makes it possible to satisfy requirements.

  5. Numerical study on determining formation porosity using a boron capture gamma ray technique and MCNP.

    PubMed

    Liu, Juntao; Zhang, Feng; Wang, Xinguang; Han, Fei; Yuan, Zhelong

    2014-12-01

    Formation porosity can be determined using the boron capture gamma ray counting ratio with a near to far detector in a pulsed neutron-gamma element logging tool. The thermal neutron distribution, boron capture gamma spectroscopy and porosity response for formations with different water salinity and wellbore diameter characteristics were simulated using the Monte Carlo method. We found that a boron lining improves the signal-to-noise ratio and that the boron capture gamma ray counting ratio has a higher sensitivity for determining porosity than total capture gamma. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. The "Case of Two Compounds with Similar Configuration but Nearly Mirror Image CD Spectra" Refuted. Reassignment of the Absolute Configuration of N-Formyl-3',4'-dihydrospiro[indan-1,2'(1'H)-pyridine].

    PubMed

    Padula, Daniele; Di Bari, Lorenzo; Pescitelli, Gennaro

    2016-09-02

    In 1997, Sandström and co-workers reported the case of two chiral spiro compounds with very similar skeletons but showing almost mirror-image electronic circular dichroism (ECD) spectra for the corresponding absolute configuration. The paper has been often cited as a proof and good educational example of the pronounced sensitivity of ECD toward molecular conformation, and a clear warning against the use of ECD spectral correlations to assign absolute configurations. Although both concepts remain valid, they are not exemplified by the quoted paper. We demonstrate that the original configurational assignment of one compound was wrong and revise it by using TDDFT calculations. The main reason for the observed failure is the use of the matrix method, a popular approach to predict ECD spectra of compounds which can be treated with an independent system approximation (ISA), including proteins. Using a modern version of the matrix method, we demonstrate that the ISA is not valid for the title compound. Even in the absence of apparent conjugation between the component chromophores, the validity of the ISA should never be taken for granted and the effective extent of orbital overlap should always be verified.

  7. Early elective cesarean delivery before 36 weeks vs late spontaneous delivery in infants with gastroschisis.

    PubMed

    Hadidi, Ahmed; Subotic, Ulrike; Goeppl, Maximilian; Waag, Karl-L

    2008-07-01

    The aim of this study is to assess the value of early elective cesarean delivery for patients with gastroschisis in comparison with late spontaneous delivery. Analysis of infants with gastroschisis admitted between 1986 and 2006 at a tertiary care center was performed. The findings were analyzed statistically. Eighty-six patients were involved in the study. This included 15 patients who underwent emergency cesarean delivery (EM CD group) because of fetal distress and/or bowel ischemia. The remaining 71 patients born electively were stratified into 4 groups. The early elective cesarean delivery (ECD) group included 23 patients born by ECD before 36 weeks; late vaginal delivery (LVD) group included 23 patients who had LVD after 36 weeks; 24 patients had LCD after 36 weeks because of delayed diagnosis that resulted in late referral; and 1 patient had early spontaneous vaginal delivery (EVD group) before 36 weeks. The mean time to start oral feeding, incidence of complications, and primary closure were significantly better in the ECD group than in the LVD group. The duration of ventilation and the length of stay were shorter in ECD group, but the difference was not statistically significant. Elective cesarean delivery before 36 weeks allows earlier enteral feeding and is associated with less complications and higher incidence of primary closure (statistically significant).

  8. DENSITY: software for analysing capture-recapture data from passive detector arrays

    USGS Publications Warehouse

    Efford, M.G.; Dawson, D.K.; Robbins, C.S.

    2004-01-01

    A general computer-intensive method is described for fitting spatial detection functions to capture-recapture data from arrays of passive detectors such as live traps and mist nets. The method is used to estimate the population density of 10 species of breeding birds sampled by mist-netting in deciduous forest at Patuxent Research Refuge, Laurel, Maryland, U.S.A., from 1961 to 1972. Total density (9.9 ? 0.6 ha-1 mean ? SE) appeared to decline over time (slope -0.41 ? 0.15 ha-1y-1). The mean precision of annual estimates for all 10 species pooled was acceptable (CV(D) = 14%). Spatial analysis of closed-population capture-recapture data highlighted deficiencies in non-spatial methodologies. For example, effective trapping area cannot be assumed constant when detection probability is variable. Simulation may be used to evaluate alternative designs for mist net arrays where density estimation is a study goal.

  9. Study on the keV neutron capture reaction in 56Fe and 57Fe

    NASA Astrophysics Data System (ADS)

    Wang, Taofeng; Lee, Manwoo; Kim, Guinyun; Ro, Tae-Ik; Kang, Yeong-Rok; Igashira, Masayuki; Katabuchi, Tatsuya

    2014-03-01

    The neutron capture cross-sections and the radiative capture gamma-ray spectra from the broad resonances of 56Fe and 57Fe in the neutron energy range from 10 to 90keV and 550keV have been measured with an anti-Compton NaI(Tl) detector. Pulsed keV neutrons were produced from the 7Li 7Be reaction by bombarding the lithium target with the 1.5ns bunched proton beam from the 3MV Pelletron accelerator. The incident neutron spectrum on a capture sample was measured by means of a time-of-flight (TOF) method with a 6Li -glass detector. The number of weighted capture counts of the iron or gold sample was obtained by applying a pulse height weighting technique to the corresponding capture gamma-ray pulse height spectrum. The neutron capture gamma-ray spectra were obtained by unfolding the observed capture gamma-ray pulse height spectra. To achieve further understanding on the mechanism of neutron radiative capture reaction and study on physics models, theoretical calculations of the -ray spectra for 56Fe and 57Fe with the POD program have been performed by applying the Hauser-Feshbach statistical model. The dominant ingredients to perform the statistical calculation were the Optical Model Potential (OMP), the level densities described by the Mengoni-Nakajima approach, and the -ray transmission coefficients described by -ray strength functions. The comparison of the theoretical calculations, performed only for the 550keV point, show a good agreement with the present experimental results.

  10. Neuropharmacological and neurochemical properties of N-(2-cyanoethyl)-2-phenylethylamine, a prodrug of 2-phenylethylamine.

    PubMed Central

    Baker, G. B.; Coutts, R. T.; Rao, T. S.

    1987-01-01

    1 N-(2-cyanoethyl)-2-phenylethylamine (CEPEA) was examined as a possible prodrug of 2-phenylethylamine (PEA). 2 Pharmacokinetics of PEA and CEPEA were investigated in rat brain, blood and liver by gas chromatography with electron-capture detection (GC-ECD). Interactions of PEA and CEPEA with putative neurotransmitter amines were investigated by use of high performance liquid chromatography with electrochemical detection (h.p.l.c.-e.c.). 3 Administration of PEA caused transient increases in PEA concentrations which decreased rapidly in brain and blood and at a slower rate in liver. Administration of CEPEA caused sustained elevations of PEA concentrations and elimination of PEA was markedly decreased in these tissues relative to the situation after administration of PEA itself. 4 Administration of CEPEA caused more prolonged decreases in brain noradrenaline, dopamine and 5-hydroxytryptamine concentrations than those observed after PEA administration, although values increased to control levels eventually. PMID:2890391

  11. Design of multivalent complexes using the barnase*barstar module.

    PubMed

    Deyev, Sergey M; Waibel, Robert; Lebedenko, Ekaterina N; Schubiger, August P; Plückthun, Andreas

    2003-12-01

    The ribonuclease barnase (12 kDa) and its inhibitor barstar (10 kDa) form a very tight complex in which all N and C termini are accessible for fusion. Here we exploit this system to create modular targeting molecules based on antibody scFv fragment fusions to barnase, to two barnase molecules in series and to barstar. We describe the construction, production and purification of defined dimeric and trimeric complexes. Immobilized barnase fusions are used to capture barstar fusions from crude extracts to yield homogeneous, heterodimeric fusion proteins. These proteins are stable, soluble and resistant to proteolysis. Using fusions with anti-p185(HER2-ECD) 4D5 scFv, we show that the anticipated gain in avidity from monomer to dimer to trimer is obtained and that favorable tumor targeting properties are achieved. Many permutations of engineered multispecific fusion proteins become accessible with this technology of quasi-covalent heterodimers.

  12. Determination of ten pyrethroids in various fruit juices: comparison of dispersive liquid-liquid microextraction sample preparation and QuEChERS method combined with dispersive liquid-liquid microextraction.

    PubMed

    Zhang, Yaohai; Zhang, Xuelian; Jiao, Bining

    2014-09-15

    Dispersive liquid-liquid microextraction (DLLME) sample preparation and the quick, easy, cheap, effective, rugged and safe (QuEChERS) method combined with DLLME were developed and compared for the analysis of ten pyrethroids in various fruit juices using gas chromatography-electron capture detection (GC-ECD). QuEChERS-DLLME method has found its widespread applications to all the fruit juices including those samples with more complex matrices (orange, lemon, kiwi and mango) while DLLME was confined to the fruit juices with simpler matrices (apple, pear, grape and peach). The two methods provided acceptable recoveries and repeatability. In addition, the applicabilities of two methods were demonstrated with the real samples and further confirmed by gas chromatography-mass spectrometry (GC-MS). Copyright © 2014. Published by Elsevier Ltd.

  13. Study of nitro-polycyclic aromatic hydrocarbons in fine and coarse atmospheric particles

    NASA Astrophysics Data System (ADS)

    Teixeira, Elba Calesso; Garcia, Karine Oliveira; Meincke, Larissa; Leal, Karen Alam

    2011-08-01

    The purpose of the present study was to evaluate six nitro-polycyclic aromatic hydrocarbons (NPAHs) in fine (< 2.5 μm) and coarse (2.5-10 μm) atmospheric particles in an urban and industrial area located in the Metropolitan Area of Porto Alegre (MAPA), RS, Brazil. The method used was of NPAHs isolation and derivatization, and subsequent gas chromatography by electron capture detection (CG/ECD). Results revealed a higher concentration of NPAHs, especially 3-nitrofluoranthene and 1-nitropyrene, in fine particles in the sampling sites studied within the MAPA. The diagnostic ratios calculated for PAHs and NPAHs identified the influence of heavy traffic, mainly of diesel emissions. The correlation of NPAHs with other pollutants (NO x, NO 2, NO and O 3) evidence the influence of vehicular emissions in the MAPA. The seasonal variation evidenced higher NPAHs concentrations in the fine particles during winter for most compounds studied.

  14. Assessment of pesticide residues in army cutworm moths (Euxoa auxiliaris) from the Greater Yellowstone Ecosystem and their potential consequences to foraging grizzly bears (Ursus arctos horribilis)

    USGS Publications Warehouse

    Robison, H.L.; Schwartz, C.C.; Petty, J.D.; Brussard, P.F.

    2006-01-01

    During summer, a grizzly bear (Ursus arctos horribilis) in the Greater Yellowstone Ecosystem (GYE) (USA) can excavate and consume millions of army cutworm moths (Euxoa auxiliaris) (ACMs) that aggregate in high elevation talus. Grizzly bears in the GYE were listed as threatened by the US Fish and Wildlife Service in 1975 and were proposed for delisting in 2005. However, questions remain about key bear foods. For example, ACMs are agricultural pests and concern exists about whether they contain pesticides that could be toxic to bears. Consequently, we investigated whether ACMs contain and transport pesticides to bear foraging sites and, if so, whether these levels could be toxic to bears. In 1999 we collected and analyzed ACMs from six bear foraging sites. ACMs were screened for 32 pesticides with gas chromatography with electron capture detection (GC-ECD). Because gas chromatography with tandem mass spectrometry (GC-MS/MS) can be more sensitive than GC-ECD for certain pesticides, we revisited one site in 2001 and analyzed these ACMs with GC-MS/MS. ACMs contained trace or undetectable levels of pesticides in 1999 and 2001, respectively. Based on chemical levels in ACMs and numbers of ACMs a bear can consume, we calculated the potential of chemicals to reach physiological toxicity. These calculations indicate bears do not consume physiologically toxic levels of pesticides and allay concerns they are at risk from pesticides transported by ACMs. If chemical control of ACMs changes in the future, screening new ACM samples taken from bear foraging sites may be warranted. ?? 2006 Elsevier Ltd. All rights reserved.

  15. Design of a compressed air modulator to be used in comprehensive multidimensional gas chromatography and its application in the determination of pesticide residues in grapes.

    PubMed

    Pizzutti, Ionara R; Vreuls, René J J; de Kok, André; Roehrs, Rafael; Martel, Samile; Friggi, Caroline A; Zanella, Renato

    2009-04-10

    In this study, a new modulator that is simple, robust and presents low operation costs, was developed. This modulator uses compressed air to cool two small portions in the first centimeters of the second chromatographic column of a comprehensive multidimensional gas chromatography (GCxGC) system. The results show a variation in the peak area less than 3 and 5% to alkanes and pesticides, respectively. The standard deviations for the retention times in the first and second dimension are around 0.05 min and 0.05s for all the compounds. The system was optimized with n-alkanes. The GCxGC system proposed was applied in the determination of pyrethroid pesticides (bifenthrin, cypermethrin, deltamethrin, fenvalerate, esfenvalerate, cis- and trans-permethrin) in grape samples. Samples were extracted by the mini-Luke modified method and pesticides were quantified by comprehensive multidimensional gas chromatography with micro electron-capture detection (microECD). The values of method limit of quantification (LOQ) were 0.01-0.02 mg kg(-1) for all studied pyrethroid and the values of recovery were between 94.3 and 115.2%, with good precision (RSD<18.4%), demonstrating that the performance of the total method consisting of a modified Luke extraction method and determination by GCxGC-microECD are satisfactory. This study also showed that the system using a modulator with a double jet of compressed air has the potential for application in the analysis of a wider range of pesticide residues in other commodities since it provides low values of LOQ with acceptable accuracy and precision.

  16. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of semivolatile organic compounds in bottom sediment by solvent extraction, gel permeation chromatographic fractionation, and capillary-column gas chromatography/mass spectrometry

    USGS Publications Warehouse

    Furlong, E.T.; Vaught, D.G.; Merten, L.M.; Foreman, W.T.; Gates, Paul M.

    1996-01-01

    A method for the determination of 79 semivolatile organic compounds (SOCs) and 4 surrogate compounds in soils and bottom sediment is described. The SOCs are extracted from bottom sediment by solvent extraction, followed by partial isolation using high-performance gel permeation chromatography (GPC). The SOCs then are qualitatively identified and quantitative concentrations determined by capillary-column gas chromatography/mass spectrometry (GC/MS). This method also is designed for an optional simultaneous isolation of polychlorinated biphenyls (PCBs) and organochlorine (OC) insecticides, including toxaphene. When OCs and PCBs are determined, an additional alumina- over-silica column chromatography step follows GPC cleanup, and quantitation is by dual capillary- column gas chromatography with electron-capture detection (GC/ECD). Bottom-sediment samples are centrifuged to remove excess water and extracted overnight with dichloromethane. The extract is concentrated, centrifuged, and then filtered through a 0.2-micrometer polytetrafluoro-ethylene syringe filter. Two aliquots of the sample extract then are quantitatively injected onto two polystyrene- divinylbenzene GPC columns connected in series. The SOCs are eluted with dichloromethane, a fraction containing the SOCs is collected, and some coextracted interferences, including elemental sulfur, are separated and discarded. The SOC-containing GPC fraction then is analyzed by GC/MS. When desired, a second aliquot from GPC is further processed for OCs and PCBs by combined alumina-over-silica column chromatography. The two fractions produced in this cleanup then are analyzed by GC/ECD. This report fully describes and is limited to the determination of SOCs by GC/MS.

  17. Characterization of low temperature metallic magnetic calorimeters having gold absorbers with implanted 163Ho ions

    NASA Astrophysics Data System (ADS)

    Gastaldo, L.; Ranitzsch, P. C.-O.; von Seggern, F.; Porst, J.-P.; Schäfer, S.; Pies, C.; Kempf, S.; Wolf, T.; Fleischmann, A.; Enss, C.; Herlert, A.; Johnston, K.

    2013-05-01

    For the first time we have investigated the behavior of fully micro-fabricated low temperature metallic magnetic calorimeters (MMCs) after undergoing an ion-implantation process. This experiment had the aim to show the possibility to perform a high precision calorimetric measurement of the energy spectrum following the electron capture of 163Ho using MMCs having the radioactive 163Ho ions implanted in the absorber. The isotope 163Ho decays through electron capture to 163Dy and features the smallest known QEC value. This peculiarity makes 163Ho a very interesting candidate to investigate the value of the electron neutrino mass by the analysis of the energy spectrum. The implantation of 163Ho ions was performed at ISOLDE-CERN. The performance of a detector that underwent an ion-implantation process is compared to the one of a detector without implanted ions. The results show that the implantation dose of ions used in this experiment does not compromise the properties of the detector. Moreover the performance of the detector prototype having the 163Ho ions implanted in the absorber is already close to the requirements needed for an experiment with sub-eV sensitivity to the electron neutrino mass. Based on these results, an optimized detector design for future 163Ho experiments is presented.

  18. Dependence of energy resolution of a plane-parallel HPGe detector on bias voltage upon registration of low-energy X-rays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Samedov, V. V., E-mail: v-samedov@yandex.ru

    2016-12-15

    In this study, we theoretically analyze the processes in a plane-parallel high-purity germanium (HPGe) detector. The generating function of factorial moments describing the process of registration of low-energy X-rays by the HPGe detector with consideration of capture of charge carriers by traps is obtained. It is demonstrated that the coefficients of expansion of the average signal amplitude and variance in power series over the quantity inversely proportional to the bias voltage of the detector allow one to determine the Fano factor, the product of the charge carrier lifetime and mobility, and other characteristics of the semiconductor material of the detector.

  19. System for detecting special nuclear materials

    DOEpatents

    Jandel, Marian; Rusev, Gencho Yordanov; Taddeucci, Terry Nicholas

    2015-07-14

    The present disclosure includes a radiological material detector having a convertor material that emits one or more photons in response to a capture of a neutron emitted by a radiological material; a photon detector arranged around the convertor material and that produces an electrical signal in response to a receipt of a photon; and a processor connected to the photon detector, the processor configured to determine the presence of a radiological material in response to a predetermined signature of the electrical signal produced at the photon detector. One or more detectors described herein can be integrated into a detection system that is suited for use in port monitoring, treaty compliance, and radiological material management activities.

  20. Review of Livermore-Led Neutron Capture Studies Using DANCE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, W; Sheets, S; Agvaanluvsan, U

    2007-05-11

    We have made neutron capture cross-section measurements using the white neutron source at the Los Alamos Science Center, the DANCE detector array (Detector for Advanced Neutron Capture Experiments) and targets important for basic science and stockpile stewardship. In this paper, we review results from (n,{gamma}) reactions on {sup 94,95}Mo, {sup 152,154,157,160,nat}Gd, {sup 151,153}Eu and {sup 242m}Am for neutron energies from < 1eV up to {approx} 20 keV. We measured details of the {gamma}-ray cascade following neutron capture, for comparison with results of statistical model simulations. We determined the neutron energy dependent (n,{gamma}) cross section and gained information about statistical decaymore » properties, including the nuclear level density and the photon strength function. Because of the high granularity of the detector array, it is possible to look at gamma cascades with a specified number of transitions (a specific multiplicity). We simulated {gamma}-ray cascades using a combination of the DICEBOX/GEANT computer codes. In the case of the deformed nuclei, we found evidence of a scissors-mode resonance. For the Eu, we also determined the (n,{gamma}) cross sections. For the {sup 94,95}Mo, we focused on the spin and parity assignments of the resonances and the determination of the photon strength functions for the compound nuclei {sup 95,96}Mo. Future plans include measurements on actinide targets; our immediate interest is in {sup 242m}Am.« less

  1. Prenatal and postnatal exposure to DDT by breast milk analysis in Canary Islands.

    PubMed

    Vall, Oriol; Gomez-Culebras, Mario; Puig, Carme; Rodriguez-Carrasco, Ernesto; Gomez Baltazar, Arelis; Canchucaja, Lizzeth; Joya, Xavier; Garcia-Algar, Oscar

    2014-01-01

    The use of p,p'-dichlorodiphenyltrichloroethane (DDT) has been banned since the late 1970s due to its toxicity. However, its long half-life makes it persistent in the environment and, consequently, almost everyone has DDT residues in the body. Human milk constitutes an ideal non-conventional matrix to investigate environmental chronic exposure to organochlorine compounds (OCs) residues. The study aimed to identify potential population risk factors of exposure to DDT due to the proximity to countries where it is still used. Seventy-two consecutive lactating women were prospectively included in Tenerife, Canary Islands (Spain). A validated questionnaire was used to obtain socioeconomic, demographics data, and daily habits during pregnancy. DDT levels in breast milk were measured by gas chromatography with-electron capture detector (GC-ECD). Anthropometrics measurements in newborns were obtained. Thirty-four out of 72 (47.2%) of the analysed milk samples presented detectable levels of DDT (mean: 0.92 ng/g), ranging between 0.08 to 16.96 ng/g. The socio-demographic variables did not significantly differ between detectable DDT and non-detectable DDT groups. We found positive association between DDT levels and vegetables (OR (95%CI): 1.23 (1.01-1.50)) and poultry meat (OR (95%CI): 2.05 (1.16-3.60)) consumption, and also between the presence of DDT in breast milk and gestational age (OR (95%CI): 0.59 (0.40-0.90)). DDT is present in breast milk of women at the time of delivery. Residual levels and the spread from countries still using DDT explain DDT detection from vegetables and from animal origin food. The presence of this compound in breast milk represents a pre- and postnatal exposure hazard for foetuses and infants due to chronic bioaccumulation and poor elimination, with possible deleterious effects on health. This data should be used to raise awareness of the risks of OCs exposure and to help establish health policies in order to avoid its use worldwide and thus, to prevent its propagation.

  2. In Situ Measurements of Sulfur Hexafluoride (SF6) and age of air from NH sources during the Atmospheric Tomography (ATom) global airborne survey

    NASA Astrophysics Data System (ADS)

    Elkins, J. W.; Moore, F. L.; Hintsa, E. J.; Ray, E. A.; Dutton, G. S.; Nance, J. D.; Hall, B. D.; Dlugokencky, E. J.; Sweeney, C.; Montzka, S. A.; Newman, P. A.

    2017-12-01

    Atmospheric SF6 is an excellent tracer of atmospheric transport in the troposphere, because of its long lifetime (850 years), mostly northern hemispheric (NH) emissions (95%), and high atmospheric growth rate ( 4%/yr.). The gas is used in the distribution of electrical power, because it is an excellent insulator. It is primarily released through its use (leaking and refilling) in high voltage power transformers. Two NOAA/GMD airborne, in situ gas chromatographs (GCs), PAN and other Trace Hydrohalocarbons ExpeRiment (PANTHER) and UAS Chromatograph for Atmospheric Trace Species (UCATS), operated on the first two circuits of the Atmospheric Tomography Mission (ATom-1 & ATom-2). Both instruments measure nitrous oxide (N2O) and sulfur hexafluoride (SF6) once every 70 seconds using a very sensitive electron capture detector (ECD). We combined both measurements into one data set for analysis of twice the amount of data, since both instruments are comparable and used the same gas standards. The main purpose of ATom is to study the influence of air quality on climate during the four seasons, where two seasons are completed so far. The altitude-latitude cross sections of SF6 mixing ratios during the ATom-1 (left) shows sources are mostly located in the NH ( 95%). The upper troposphere shows inter-hemispheric mixing. The polar stratosphere shows older air that is mixed with air from the mesospheric sink. Using the procedure described by Waugh et al., (2013) [JGR-Atmos. 10.1002/jgrd.50189] and a recent growth rate of 0.32 ppt yr-1, we have calculated the mean age of each SF6 measurement from its source at ground level in the NH (lat. range of 30-50°N). The contours of age (right) are in agreement with the mean inter-hemispheric exchange time (τNS) of 1.2 yr and higher ages in the polar stratosphere (2.5-3.0 yr).

  3. Factorial-design optimization of gas chromatographic analysis of tetrabrominated to decabrominated diphenyl ethers. Application to domestic dust.

    PubMed

    Regueiro, Jorge; Llompart, Maria; Garcia-Jares, Carmen; Cela, Rafael

    2007-07-01

    Gas chromatographic analysis of polybrominated diphenyl ethers (PBDEs) has been evaluated in an attempt to achieve better control of the separation process, especially for highly substituted congeners. Use of a narrow-bore capillary column enabled adequate determination of tetra, penta, hexa, hepta, octa, nona and decaBDE congeners in only one chromatographic run while maintaining resolution power similar to that of conventional columns. A micro electron-capture detector (GC-microECD) was used. Chromatographic conditions were optimized by multifactorial experimental design, with the objective of obtaining not only high sensitivity but also good precision. In this way two different approaches to maximizing response and minimizing variability were tested, and are fully discussed. These optimum chromatographic conditions were then used to determine PBDEs extracted from domestic dust samples by microwave-assisted solvent extraction (MASE). Quantitative recovery (90-108%) was achieved for all the PBDEs and method precision (RSD < 13%) was satisfactory. Accuracy was tested by use of the standard reference material SRM 2585, and sub-ng g(-1) limits of detection were obtained for all compounds except BDE-209 (1.44 ng g(-1)). Finally, several samples of house dust were analysed by use of the proposed method and all the target PBDEs were detected in all the samples. BDE-209 was the predominant congener. Amounts varied from 58 to 1615 ng g(-1) and the average contribution to the total PBDE burden of 52%. The main congeners of the octaBDE mixture (BDE-183, BDE-197, BDE-207 and BDE-196) also made an important contribution (29%) to the total. These are the first data about the presence of these compounds in European house-dust samples. Finally, the sum of the main congeners in the pentaBDE commercial mixture (BDE-47, BDE-99, and BDE-100) contributed 14% to the total. Figure Polybrominated diphenyl ethers in House Dust.

  4. Current and Future Research at DANCE

    NASA Astrophysics Data System (ADS)

    Jandel, M.; Baramsai, B.; Bredeweg, T. A.; Couture, A.; Hayes, A.; Kawano, T.; Mosby, S.; Rusev, G.; Stetcu, I.; Taddeucci, T. N.; Talou, P.; Ullmann, J. L.; Walker, C. L.; Wilhelmy, J. B.

    2015-05-01

    An overview of the current experimental program on measurements of neutron capture and neutron induced fission at the Detector for Advanced Neutron Capture Experiments (DANCE) is presented. Three major projects are currently under way: 1) high precision measurements of neutron capture cross sections on Uranium isotopes, 2) research aimed at studies of the short-lived actinide isomer production in neutron capture on 235U and 3) measurements of correlated data of fission observables. New projects include developments of auxiliary detectors to improve the capability of DANCE. We are building a compact, segmented NEUtron detector Array at DANCE (NEUANCE), which will be installed in the central cavity of the DANCE array. It will provide experimental information on prompt fission neutrons in coincidence with the prompt fission gamma-rays measured by 160 BaF2 crystals of DANCE. Unique correlated data will be obtained for neutron capture and neutron-induced fission using the DANCE-NEUANCE experimental set up in the future.

  5. Integrating Early Child Development and Violence Prevention Programs: A Systematic Review.

    PubMed

    Efevbera, Yvette; McCoy, Dana C; Wuermli, Alice J; Betancourt, Theresa S

    2018-03-01

    Limited evidence describes promoting development and reducing violence in low- and middle-income countries (LMICs), a missed opportunity to protect children and promote development and human capital. This study presents a systematic literature review of integrated early childhood development plus violence prevention (ECD+VP) interventions in LMICs. The search yielded 5,244 unique records, of which N = 6 studies met inclusion criteria. Interventions were in Chile, Jamaica, Lebanon, Mexico, Mozambique, and Turkey. Five interventions were parent education programs, including center-based sessions (n = 3) and home visiting (n = 2), while one intervention was a teacher education program. All but one study reported improvements in both child development and maltreatment outcomes. The dearth of evidence on ECD+VP interventions suggests additional research is needed. Integrated ECD+VP interventions may improve multiple child outcome domains while leveraging limited resources in LMICs. © 2018 Wiley Periodicals, Inc.

  6. Performance evaluation of a modular detector unit for X-ray computed tomography.

    PubMed

    Guo, Zhe; Tang, Zhiwei; Wang, Xinzeng; Deng, Mingliang; Hu, Guangshu; Zhang, Hui

    2013-04-18

    A research prototype CT scanner is currently under development in our lab. One of the key components in this project is the CT detector. This paper describes the design and performance evaluation of the modular CT detector unit for our proposed scanner. It consists of a Photodiode Array Assembly which captures irradiating X-ray photons and converts the energy into electrical current, and a mini Data Acquisition System which performs current integration and converts the analog signal into digital samples. The detector unit can be easily tiled together to form a CT detector. Experiments were conducted to characterize the detector performance both at the single unit level and system level. The noise level, linearity and uniformity of the proposed detector unit were reported and initial imaging studies were also presented which demonstrated the potential application of the proposed detector unit in actual CT scanners.

  7. NASA Tech Briefs, July 2008

    NASA Technical Reports Server (NTRS)

    2008-01-01

    Topics covered include: Torque Sensor Based on Tunnel-Diode Oscillator; Shaft-Angle Sensor Based on Tunnel-Diode Oscillator; Ground Facility for Vicarious Calibration of Skyborne Sensors; Optical Pressure-Temperature Sensor for a Combustion Chamber; Impact-Locator Sensor Panels; Low-Loss Waveguides for Terahertz Frequencies; MEMS/ECD Method for Making Bi(2-x)Sb(x)Te3 Thermoelectric Devices; Low-Temperature Supercapacitors; Making a Back-Illuminated Imager with Back-Side Contact and Alignment Markers; Compact, Single-Stage MMIC InP HEMT Amplifier; Nb(x)Ti(1-x)N Superconducting-Nanowire Single-Photon Detectors; Improved Sand-Compaction Method for Lost-Foam Metal Casting; Improved Probe for Evaluating Compaction of Mold Sand; Polymer-Based Composite Catholytes for Li Thin-Film Cells; Using ALD To Bond CNTs to Substrates and Matrices; Alternating-Composition Layered Ceramic Barrier Coatings; Variable-Structure Control of a Model Glider Airplane; Axial Halbach Magnetic Bearings; Compact, Non-Pneumatic Rock-Powder Samplers; Biochips Containing Arrays of Carbon-Nanotube Electrodes; Nb(x)Ti(1-x)N Superconducting-Nanowire Single-Photon Detectors; Neon as a Buffer Gas for a Mercury-Ion Clock; Miniature Incandescent Lamps as Fiber-Optic Light Sources; Bidirectional Pressure-Regulator System; and Prism Window for Optical Alignment. Single-Grid-Pair Fourier Telescope for Imaging in Hard-X Rays and gamma Rays Range-Gated Metrology with Compact Optical Head Lossless, Multi-Spectral Data Compressor for Improved Compression for Pushbroom-Typetruments.

  8. Determination of acaricide residues in saudi arabian honey and beeswax using solid phase extraction and gas chromatography.

    PubMed

    Kamel, Alaa; Al-Ghamdi, Ahmad

    2006-01-01

    Determination of acaricide residues of flumethrin, tau-fluvalinate, coumaphos, and amitraz in honey and beeswax was carried out using a rapid extraction method utilizing C-18 SPE cartridges and an analytical method utilizing GC with ECD, NPD, and MSD detectors for the four acaricides. Recovery percentages from the extraction method ranged from 90-102%, while the minimum detection levels ranged from 0.01-0.05 mg/kg for the acaricides. Nine of the 21 analyzed samples were found to be contaminated with the acaricides tau-fluvalinate and coumaphos. Neither flumethrin nor amitraz was detected in any of the honey or wax samples. Coumaphos was found only in honey samples in which two samples exceeded the tolerance levels set by EPA and EC regulations. It has not been detected in beeswax. Five honey samples and eight beeswax samples were found to be contaminated with tau-fluvalinate. One of the wax samples was contaminated with a relatively high residue of tau-fluvalinate and contained above 10 mg/kg.

  9. Prioritizing research for integrated implementation of early childhood development and maternal, newborn, child and adolescent health and nutrition platforms.

    PubMed

    Sharma, Renee; Gaffey, Michelle F; Alderman, Harold; Bassani, Diego G; Bogard, Kimber; Darmstadt, Gary L; Das, Jai K; de Graft-Johnson, Joseph E; Hamadani, Jena D; Horton, Susan; Huicho, Luis; Hussein, Julia; Lye, Stephen; Pérez-Escamilla, Rafael; Proulx, Kerrie; Marfo, Kofi; Mathews-Hanna, Vanessa; Mclean, Mireille S; Rahman, Atif; Silver, Karlee L; Singla, Daisy R; Webb, Patrick; Bhutta, Zulfiqar A

    2017-06-01

    Existing health and nutrition services present potential platforms for scaling up delivery of early childhood development (ECD) interventions within sensitive windows across the life course, especially in the first 1000 days from conception to age 2 years. However, there is insufficient knowledge on how to optimize implementation for such strategies in an integrated manner. In light of this knowledge gap, we aimed to systematically identify a set of integrated implementation research priorities for health, nutrition and early child development within the 2015 to 2030 timeframe of the Sustainable Development Goals (SDGs). We applied the Child Health and Nutrition Research Initiative method, and consulted a diverse group of global health experts to develop and score 57 research questions against five criteria: answerability, effectiveness, deliverability, impact, and effect on equity. These questions were ranked using a research priority score, and the average expert agreement score was calculated for each question. The research priority scores ranged from 61.01 to 93.52, with a median of 82.87. The average expert agreement scores ranged from 0.50 to 0.90, with a median of 0.75. The top-ranked research question were: i) "How can interventions and packages to reduce neonatal mortality be expanded to include ECD and stimulation interventions?"; ii) "How does the integration of ECD and MNCAH&N interventions affect human resource requirements and capacity development in resource-poor settings?"; and iii) "How can integrated interventions be tailored to vulnerable refugee and migrant populations to protect against poor ECD and MNCAH&N outcomes?". Most highly-ranked research priorities varied across the life course and highlighted key aspects of scaling up coverage of integrated interventions in resource-limited settings, including: workforce and capacity development, cost-effectiveness and strategies to reduce financial barriers, and quality assessment of programs. Investing in ECD is critical to achieving several of the SDGs, including SDG 2 on ending all forms of malnutrition, SDG 3 on ensuring health and well-being for all, and SDG 4 on ensuring inclusive and equitable quality education and promotion of life-long learning opportunities for all. The generated research agenda is expected to drive action and investment on priority approaches to integrating ECD interventions within existing health and nutrition services.

  10. The Impact of Seed Layer Structure on the Recrystallization of ECD Cu and its Alloys

    NASA Astrophysics Data System (ADS)

    O'Brien, Brendan B.

    Despite the significant improvements originally offered by the use of Cu over Al as the interconnect material for semiconductor devices, the continued down-scaling of interconnects has presented significant challenges for semiconductor engineers. As the metal line widths shrink, both the conductivity and reliability of lines decrease due to a stubbornly fine-grained microstructure in narrow lines. Understanding microstructural transformation of the ECD Cu in narrow features which leads to this polygranular microstructure is the first focus of this dissertation. As in the case of Cu films, the underlying seed layer strongly influences progress of transformation. Unlike films, however, the seed layer is not homogenous in patterned substrates, but differs according to the size of the trench and the location within the trench (field, bottom, and sidewall). Based on these findings, and the known influence of texture on the transformation of ECD Cu, a rapid trench initiated transformation process was posited for narrow interconnect lines. Time-resolved TEM observation of the ECD Cu in 48 nm lines during the transformation process confirmed the hypothesis. In fact, the TEM images revealed that the transformation was even faster than anticipated, and that the microstructure of the Cu inside the lines was stagnant after a mere 1.5 hours at room temperature. Studies of the transformation at elevated temperatures found that, despite anneals at 250°C for up to an hour, the grain size distribution for the Cu in narrow lines for all times converged, whether annealed at room temperature or 250°C. These data suggest that process was being driven by the 'consumable' internal energy stored in the as-plated microstructure. This is different than the transformation of the overburden, which is driven by a competition between surface energy and internal stress buildup due to film densification and relief due to the secondary growth of a 200 texture component. Based on these findings, two methods for manipulating the microstructure of the ECD Cu in the narrow lines were explored, including changes to the seed layer through ion implantation, and altering the as-plated Cu microstructure through co-ECD of alloys. The influence on the microstructure and applicability of both of these techniques to BEOL processing will also be discussed.

  11. Correlation of Tc-99 m ethyl cysteinate dimer single-photon emission computed tomography and clinical presentations in patients with low cobalamin status.

    PubMed

    Tu, Min-Chien; Lo, Chung-Ping; Chen, Ching-Yuan; Huang, Ching-Feng

    2015-12-03

    Cobalamin (Cbl) deficiency has been associated with various neuropsychiatric symptoms of different severities. While some studies dedicated in structural neuroimaging credibly address negative impact of low Cbl status, functional imaging reports are limited. We herein retrospectively review the correlation of Tc-99 m ethyl cysteinate dimer single-photon emission computed tomography (Tc-99 m-ECD SPECT) and clinical presentations among patients with low serum cobalamin (Cbl) status (<250 pg/ml). Twelve symptomatic patients with low serum Cbl status were enrolled. Clinical presentations, Tc-99 m-ECD SPECT, and neuropsychological tests were reviewed. Dysexecutive syndrome (67 %), forgetfulness (50 %), attention deficits (42 %), and sleep disorders (33 %) constituted the major clinical presentations. All patients (100 %) had temporal hypoperfusion on the Tc-99 m-ECD SPECT. Five patients (42 %) had hypoperfusion restricted within temporal regions and deep nuclei; seven patients (58 %) had additional frontal hypoperfusion. In patients with hypoperfusion restricted within temporal regions and deep nuclei, psychiatric symptoms with spared cognition were their main presentations. Among patients with additional frontal hypoperfusion, six of seven patients (86 %) showed impaired cognitive performances (two of them were diagnosed as having dementia). Among ten patients who finished neuropsychological tests, abstract thinking (70 %) was the most commonly affected, followed by verbal fluency (60 %), short-term memory (50 %), and attention (50 %). Anxiety and sleep problems were the major clinically remarkable psychiatric features (33 % both). Four Tc-99 m-ECD SPECT follow-up studies were available; the degree and extent of signal reversal correlated with cognitive changes after Cbl replacement therapy. Our TC-99 m-ECD SPECT observations provide pivotal information of neurobiological changes within basal ganglia and fronto-temporal regions in conjunction with disease severity among patients with Cbl deficiency. Hypoperfusion within thalamus/basal ganglia and temporal regions may be seen in the earlier state of Cbl deficiency, when psychiatric symptoms predominate. Hypoperfusion beyond thalamus/basal ganglia and involving frontal regions appears when cognitive problems, mostly dysexecutive syndrome, are manifested. Symmetric hypofrontality of SPECT in the context of dysexcutive syndrome serves as a distinguishing feature of non-amnestic mild cognitive impairment attributed to Cbl deficiency. Concordant with TC-99 m-ECD SPECT findings, the psychiatric symptoms and dysexcutive syndrome undergird impaired limbic and dorsolateral prefrontal circuits originating from basal ganglia respectively.

  12. Prioritizing research for integrated implementation of early childhood development and maternal, newborn, child and adolescent health and nutrition platforms

    PubMed Central

    Sharma, Renee; Gaffey, Michelle F; Alderman, Harold; Bassani, Diego G; Bogard, Kimber; Darmstadt, Gary L; Das, Jai K; de Graft–Johnson, Joseph E; Hamadani, Jena D; Horton, Susan; Huicho, Luis; Hussein, Julia; Lye, Stephen; Pérez–Escamilla, Rafael; Proulx, Kerrie; Marfo, Kofi; Mathews–Hanna, Vanessa; Mclean, Mireille S; Rahman, Atif; Silver, Karlee L; Singla, Daisy R; Webb, Patrick; Bhutta, Zulfiqar A

    2017-01-01

    Background Existing health and nutrition services present potential platforms for scaling up delivery of early childhood development (ECD) interventions within sensitive windows across the life course, especially in the first 1000 days from conception to age 2 years. However, there is insufficient knowledge on how to optimize implementation for such strategies in an integrated manner. In light of this knowledge gap, we aimed to systematically identify a set of integrated implementation research priorities for health, nutrition and early child development within the 2015 to 2030 timeframe of the Sustainable Development Goals (SDGs). Methods We applied the Child Health and Nutrition Research Initiative method, and consulted a diverse group of global health experts to develop and score 57 research questions against five criteria: answerability, effectiveness, deliverability, impact, and effect on equity. These questions were ranked using a research priority score, and the average expert agreement score was calculated for each question. Findings The research priority scores ranged from 61.01 to 93.52, with a median of 82.87. The average expert agreement scores ranged from 0.50 to 0.90, with a median of 0.75. The top–ranked research question were: i) “How can interventions and packages to reduce neonatal mortality be expanded to include ECD and stimulation interventions?”; ii) “How does the integration of ECD and MNCAH&N interventions affect human resource requirements and capacity development in resource–poor settings?”; and iii) “How can integrated interventions be tailored to vulnerable refugee and migrant populations to protect against poor ECD and MNCAH&N outcomes?”. Most highly–ranked research priorities varied across the life course and highlighted key aspects of scaling up coverage of integrated interventions in resource–limited settings, including: workforce and capacity development, cost–effectiveness and strategies to reduce financial barriers, and quality assessment of programs. Conclusions Investing in ECD is critical to achieving several of the SDGs, including SDG 2 on ending all forms of malnutrition, SDG 3 on ensuring health and well–being for all, and SDG 4 on ensuring inclusive and equitable quality education and promotion of life–long learning opportunities for all. The generated research agenda is expected to drive action and investment on priority approaches to integrating ECD interventions within existing health and nutrition services. PMID:28685048

  13. hEcd, A Novel Regulator of Mammary Epithelial Cell Survival

    DTIC Science & Technology

    2009-09-01

    theYeast Two hybrid analysis with human papilloma virus oncogene E6 (the most efficient oncogene to immortalize hMECs in vitro) as a bait and mammary...transformation. We have identified a novel protein us ing the Yeast Two hybrid analysis with human papilloma virus oncogene E6 (the most efficient...epithelial cell cDNA library, we identified hEcd ( human orthologue of Drosophila Ecdysoneless) as a novel E6 binding partner. To study the cellular

  14. A clinical assessment of the anterior eye in arc welders.

    PubMed

    Doughty, Michael J; Oblak, Emil

    2005-11-01

    Corneal irradiation with high doses of ultraviolet-B (UVB) has been shown to damage the corneal endothelium in animals. Human occupational exposure to ultraviolet radiation (UVR) in welding is considered a risk for endothelial damage but the evidence for such an effect is limited. External eye photographs and non-contact specular micrographs (Topcon SP2000-P) were obtained from 102 white males aged between 32 and 62 years, 51 being arc welders (with 24 +/- 7 years experience) and 51 office workers. Most welders reported repeated occupational exposure to UVR (that is, welder's 'flashes'). Welders reported a higher level of ocular symptoms and a higher prevalence of pingueculae (47 versus 12 per cent), but only one case with pterygium. The average endothelial cell areas were the same in welders and office workers (398 +/- 55 microm(2) versus 400 +/- 56 microm(2); p = 0.868) as were the endothelial cell density (ECD) values (2,555 +/- 342 cells/mm(2) versus 2,541 +/- 308 cells/mm(2); p = 0.825). ECD decreased with years of welding experience (p < 0.01) but not faster than the decrease in ECD due to age. Repeated occupational ultraviolet radiation exposure through welding is not associated with any obvious differences in the corneal endothelium. No differences were observed in either ECD or cell polymegethism. Despite the periodic welding flashes, the exposure levels are below those needed to cause damage to the corneal endothelium.

  15. Interaction of Extracellular Domain 2 of the Human Retina-specific ATP-binding Cassette Transporter (ABCA4) with All-trans-retinal*

    PubMed Central

    Biswas-Fiss, Esther E.; Kurpad, Deepa S.; Joshi, Kinjalben; Biswas, Subhasis B.

    2010-01-01

    The retina-specific ATP-binding cassette (ABC) transporter, ABCA4, is essential for transport of all-trans-retinal from the rod outer segment discs in the retina and is associated with a broad range of inherited retinal diseases, including Stargardt disease, autosomal recessive cone rod dystrophy, and fundus flavimaculatus. A unique feature of the ABCA subfamily of ABC transporters is the presence of highly conserved, long extracellular loops or domains (ECDs) with unknown function. The high degree of sequence conservation and mapped disease-associated mutations in these domains suggests an important physiological significance. Conformational analysis using CD spectroscopy of purified, recombinant ECD2 protein demonstrated that it has an ordered and stable structure composed of 27 ± 3% α-helix, 20 ± 3% β-pleated sheet, and 53 ± 3% coil. Significant conformational changes were observed in disease-associated mutant proteins. Using intrinsic tryptophan fluorescence emission spectrum of ECD2 polypeptide and fluorescence anisotropy, we have demonstrated that this domain specifically interacts with all-trans-retinal. Furthermore, the retinal interaction appeared preferential for the all-trans-isomer and was directly measurable through fluorescence anisotropy analysis. Our results demonstrate that the three macular degeneration-associated mutations lead to significant changes in the secondary structure of the ECD2 domain of ABCA4, as well as in its interaction with all-trans-retinal. PMID:20404325

  16. [Advances in early childhood development: from neurons to big scale programs].

    PubMed

    Pérez-Escamilla, Rafael; Rizzoli-Córdoba, Antonio; Alonso-Cuevas, Aranzazú; Reyes-Morales, Hortensia

    Early childhood development (ECD) is the basis of countries' economic and social development and their ability to meet the Sustainable Development Goals (SDGs). Gestation and the first three years of life are critical for children to have adequate physical, psychosocial, emotional and cognitive development for the rest of their lives. Nurturing care and protection of children during gestation and early childhood are necessary for the development of trillions of neurons and trillions of synapses necessary for development. ECD requires access to good nutrition and health services from gestation, responsive caregiving according to the child's developmental stage, social protection and child welfare, and early stimulation and learning opportunities. Six actions are recommended to improve national ECD programs: expand political will and funding; create a supportive, evidence-based policy environment; build capacity through inter-sectoral coordination; ensure fair and transparent governance of programs and services; increase support for multidisciplinary research; and promote the development of leaders. Mexico has made significant progress under the leadership of the Health Ministry, but still faces significant challenges. The recent creation of a national inter-sectoral framework to enable ECD with support of international organizations and the participation of civil society organizations can help overcome these challenges. Copyright © 2017 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.

  17. Molecular recognition of parathyroid hormone by its G protein-coupled receptor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pioszak, Augen A.; Xu, H. Eric

    Parathyroid hormone (PTH) is central to calcium homeostasis and bone maintenance in vertebrates, and as such it has been used for treating osteoporosis. It acts primarily by binding to its receptor, PTH1R, a member of the class B G protein-coupled receptor (GPCR) family that also includes receptors for glucagon, calcitonin, and other therapeutically important peptide hormones. Despite considerable interest and much research, determining the structure of the receptor-hormone complex has been hindered by difficulties in purifying the receptor and obtaining diffraction-quality crystals. Here, we present a method for expression and purification of the extracellular domain (ECD) of human PTH1R engineeredmore » as a maltose-binding protein (MBP) fusion that readily crystallizes. The 1.95-{angstrom} structure of PTH bound to the MBP-PTH1R-ECD fusion reveals that PTH docks as an amphipathic helix into a central hydrophobic groove formed by a three-layer {alpha}-{beta}-{beta}{alpha} fold of the PTH1R ECD, resembling a hot dog in a bun. Conservation in the ECD scaffold and the helical structure of peptide hormones emphasizes this hot dog model as a general mechanism of hormone recognition common to class B GPCRs. Our findings reveal critical insights into PTH actions and provide a rational template for drug design that targets this hormone signaling pathway.« less

  18. Mechanistic Study on Electronic Excitation Dissociation of the Cellobiose-Na+ Complex

    NASA Astrophysics Data System (ADS)

    Huang, Yiqun; Pu, Yi; Yu, Xiang; Costello, Catherine E.; Lin, Cheng

    2016-02-01

    The recent development of electron activated dissociation (ExD) techniques has opened the door for high-throughput, detailed glycan structural elucidation. Among them, ExD methods employing higher-energy electrons offer several advantages over low-energy electron capture dissociation (ECD), owing to their applicability towards chromophore-labeled glycans and singly charged ions, and ability to provide more extensive structural information. However, a lack of understanding of these processes has hindered rational optimization of the experimental conditions for more efficient fragmentation as well as the development of informatics tools for interpretation of the complex glycan ExD spectra. Here, cellobiose-Na+ was used as the model system to investigate the fragmentation behavior of metal-adducted glycans under irradiation of electrons with energy exceeding their ionization potential, and served as the basis on which a novel electronic excitation dissociation (EED) mechanism was proposed. It was found that ionization of the glycan produces a mixture of radical cations and ring-opened distonic ions. These distonic ions then capture a low-energy electron to produce diradicals with trivial singlet-triplet splitting, and subsequently undergo radical-induced dissociation to produce a variety of fragment ions, the abundances of which are influenced by the stability of the distonic ions from which they originate.

  19. Determination of guaifenesin in human serum by capillary gas chromatography and electron capture detection.

    PubMed

    Sharaf, Maged H M; Stiff, Dwight D

    2004-06-29

    A method for the quantitation of guaifenesin in human serum has been developed and validated. The procedure involves liquid-liquid extraction of the serum sample in the presence of mephenesin as an internal standard, followed by derivatization and analysis using capillary gas chromatography (GC) and electron capture detection (ECD). Different solvents were tested for extraction of guaifenesin from serum. n-Hexane/dichloromethane (1:1, v/v) gave the highest recovery and the lowest background and was chosen as the extraction solvent. After extraction, the residue of guaifenesin was derivatized at 60 degrees C for 30 min, with trifluoroacetic acid anhydride (TFAA) in toluene in the presence of pyridine. Excess trifluoroacetic acid anhydride was removed using dilute solution of ammonium hydroxide. The method proved to be linear over the range of 25.0-1000 ng/ml. Recovery of guaifenesin from spiked samples was consistent, averaging 75.5% at 50.0 ng/ml with a range of 72.0-80.0% (N = 8 determinations) and averaging 78% at 800 ng/ml with a range of 76.0-81.0% (N = 8 determinations). The internal standard recovery was also consistent averaging 72.8% with a range of 67.0-76.0% (N = 16 determinations). Copyright 2004 Elsevier B.V.

  20. Neutron capture cross section of ^243Am

    NASA Astrophysics Data System (ADS)

    Jandel, M.

    2009-10-01

    The Detector for Advanced Neutron Capture Experiments (DANCE) at Los Alamos National Laboratory (LANL) was used for neutron capture cross section measurement on ^243Am. The high granularity of DANCE (160 BaF2 detectors in a 4π geometry) enables the efficient detection of prompt gamma-rays following neutron capture. DANCE is located on the 20.26 m neutron flight path 14 (FP14) at the Manuel Lujan Jr. Neutron Scattering Center at the Los Alamos Neutron Science Center (LANSCE). The methods and techniques established in [1] were used for the determination of the ^243Am neutron capture cross section. The cross sections were obtained in the range of neutron energies from 0.02 eV to 400 keV. The resonance region was analyzed using SAMMY7 and resonance parameters were extracted. The results will be compared to existing evaluations and calculations. Work was performed under the auspices of the U.S. Department of Energy at Los Alamos National Laboratory by the Los Alamos National Security, LLC under Contract No. DE-AC52-06NA25396 and at Lawrence Livermore National Laboratory by the Lawrence Livermore National Security, LLC under Contract No. DE-AC52-07NA27344. [4pt] [1] M. Jandel et al., Phys. Rev. C78, 034609 (2008)

Top