Sample records for capture therapy application

  1. Neutron capture therapies

    DOEpatents

    Yanch, Jacquelyn C.; Shefer, Ruth E.; Klinkowstein, Robert E.

    1999-01-01

    In one embodiment there is provided an application of the .sup.10 B(n,.alpha.).sup.7 Li nuclear reaction or other neutron capture reactions for the treatment of rheumatoid arthritis. This application, called Boron Neutron Capture Synovectomy (BNCS), requires substantially altered demands on neutron beam design than for instance treatment of deep seated tumors. Considerations for neutron beam design for the treatment of arthritic joints via BNCS are provided for, and comparisons with the design requirements for Boron Neutron Capture Therapy (BNCT) of tumors are made. In addition, exemplary moderator/reflector assemblies are provided which produce intense, high-quality neutron beams based on (p,n) accelerator-based reactions. In another embodiment there is provided the use of deuteron-based charged particle reactions to be used as sources for epithermal or thermal neutron beams for neutron capture therapies. Many d,n reactions (e.g. using deuterium, tritium or beryllium targets) are very prolific at relatively low deuteron energies.

  2. Neutron therapy of cancer

    NASA Technical Reports Server (NTRS)

    Frigerio, N. A.; Nellans, H. N.; Shaw, M. J.

    1969-01-01

    Reports relate applications of neutrons to the problem of cancer therapy. The biochemical and biophysical aspects of fast-neutron therapy, neutron-capture and neutron-conversion therapy with intermediate-range neutrons are presented. Also included is a computer program for neutron-gamma radiobiology.

  3. Epithermal neutron beams from the 7 Li(p,n) reaction near the threshold for neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Porras, I.; Praena, J.; Arias de Saavedra, F.; Pedrosa, M.; Esquinas, P.; L. Jiménez-Bonilla, P.

    2016-11-01

    Two applications for neutron capture therapy of epithermal neutron beams calculated from the 7Li ( p , n reaction are discussed. In particular, i) for a proton beam of 1920 keV of a 30 mA, a neutron beam of adequate features for BNCT is found at an angle of 80° from the forward direction; and ii) for a proton beam of 1910 keV, a neutron beam is obtained at the forward direction suitable for performing radiobiology experiments for the determination of the biological weighting factors of the fast dose component in neutron capture therapy.

  4. Insights into the use of gadolinium and gadolinium/boron-based agents in imaging-guided neutron capture therapy applications.

    PubMed

    Deagostino, Annamaria; Protti, Nicoletta; Alberti, Diego; Boggio, Paolo; Bortolussi, Silva; Altieri, Saverio; Crich, Simonetta Geninatti

    2016-05-01

    Gadolinium neutron capture therapy (Gd-NCT) is currently under development as an alternative approach for cancer therapy. All of the clinical experience to date with NCT is done with (10)B, known as boron neutron capture therapy (BNCT), a binary treatment combining neutron irradiation with the delivery of boron-containing compounds to tumors. Currently, the use of Gd for NCT has been getting more attention because of its highest neutron cross-section. Although Gd-NCT was first proposed many years ago, its development has suffered due to lack of appropriate tumor-selective Gd agents. This review aims to highlight the recent advances for the design, synthesis and biological testing of new Gd- and B-Gd-containing compounds with the task of finding the best systems able to improve the NCT clinical outcome.

  5. Theoretical and experimental physical methods of neutron-capture therapy

    NASA Astrophysics Data System (ADS)

    Borisov, G. I.

    2011-09-01

    This review is based to a substantial degree on our priority developments and research at the IR-8 reactor of the Russian Research Centre Kurchatov Institute. New theoretical and experimental methods of neutron-capture therapy are developed and applied in practice; these are: A general analytical and semi-empiric theory of neutron-capture therapy (NCT) based on classical neutron physics and its main sections (elementary theories of moderation, diffuse, reflection, and absorption of neutrons) rather than on methods of mathematical simulation. The theory is, first of all, intended for practical application by physicists, engineers, biologists, and physicians. This theory can be mastered by anyone with a higher education of almost any kind and minimal experience in operating a personal computer.

  6. Application of boronated anti-CEA immunoliposome to tumour cell growth inhibition in in vitro boron neutron capture therapy model.

    PubMed Central

    Yanagië, H.; Tomita, T.; Kobayashi, H.; Fujii, Y.; Takahashi, T.; Hasumi, K.; Nariuchi, H.; Sekiguchi, M.

    1991-01-01

    An immunoliposome containing a 10B-compound has been examined as a selective drug delivery system in boron neutron-capture therapy. Liposomes, conjugated with monoclonal antibodies specific for carcinoembryonic antigen (CEA) were shown to bind selectively to cells bearing CEA on their surface. The immunoliposomes attached to tumour cells suppressed growth in vitro upon thermal neutron irradiation and suppression was dependent upon the concentration of the 10B-compound in the liposomes and on the density of antibody conjugated to the liposomes. The results suggest that immunoliposomes containing the 10B-compound could act as a selective and efficient carrier of 10B atoms to target tumour cells in boron neutron-capture therapy. Images Figure 1 PMID:2021537

  7. Towards boron neutron capture therapy: the formulation and preliminary in vitro evaluation of liposomal vehicles for the therapeutic delivery of the dequalinium salt of bis-nido-carborane.

    PubMed

    Theodoropoulos, Dimitrios; Rova, Aikaterini; Smith, James R; Barbu, Eugen; Calabrese, Gianpiero; Vizirianakis, Ioannis S; Tsibouklis, John; Fatouros, Dimitrios G

    2013-11-15

    Liposomes of phosphatidylcholine or of dimyristoylphosphatidylcholine that incorporate bis-nido-carborane dequalinium salt are stable in physiologically relevant media and have in vitro toxicity profiles that appear to be compatible with potential therapeutic applications. These features render the structures suitable candidate boron-delivery vehicles for evaluation in the boron neutron capture therapy of cancer. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Analysis on the emission and potential application of Cherenkov radiation in boron neutron capture therapy: A Monte Carlo simulation study.

    PubMed

    Shu, Di-Yun; Geng, Chang-Ran; Tang, Xiao-Bin; Gong, Chun-Hui; Shao, Wen-Cheng; Ai, Yao

    2018-07-01

    This paper was aimed to explore the physics of Cherenkov radiation and its potential application in boron neutron capture therapy (BNCT). The Monte Carlo toolkit Geant4 was used to simulate the interaction between the epithermal neutron beam and the phantom containing boron-10. Results showed that Cherenkov photons can only be generated from secondary charged particles of gamma rays in BNCT, in which the 2.223 MeV prompt gamma rays are the main contributor. The number of Cherenkov photons per unit mass generated in the measurement region decreases linearly with the increase of boron concentration in both water and tissue phantom. The work presented the fundamental basis for applications of Cherenkov radiation in BNCT. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Application of an octa-anionic 5,10,15,20-tetra[3,5-(nido-carboranylmethyl)phenyl]porphyrin (H2OCP) as dual sensitizer for BNCT and PDT

    USDA-ARS?s Scientific Manuscript database

    The applications of the octa-anionic 5,10,15,20-tetra[3,5-(nidocarboranylmethyl) phenyl]porphyrin (H2OCP) as a boron delivery agent in boron neutron capture therapy (BNCT) and a photosensitizer in photodynamic therapy (PDT) have been investigated. Using F98 Rat glioma cells, we evaluated the cytotox...

  10. Cellular uptake and in vitro antitumor efficacy of composite liposomes for neutron capture therapy.

    PubMed

    Peters, Tanja; Grunewald, Catrin; Blaickner, Matthias; Ziegner, Markus; Schütz, Christian; Iffland, Dorothee; Hampel, Gabriele; Nawroth, Thomas; Langguth, Peter

    2015-02-22

    Neutron capture therapy for glioblastoma has focused mainly on the use of (10)B as neutron capture isotope. However, (157)Gd offers several advantages over boron, such as higher cross section for thermal neutrons and the possibility to perform magnetic resonance imaging during neutron irradiation, thereby combining therapy and diagnostics. We have developed different liposomal formulations of gadolinium-DTPA (Magnevist®) for application in neutron capture therapy of glioblastoma. The formulations were characterized physicochemically and tested in vitro in a glioma cell model for their effectiveness. Liposomes entrapping gadolinium-DTPA as neutron capture agent were manufactured via lipid/film-extrusion method and characterized with regard to size, entrapment efficiency and in vitro release. For neutron irradiation, F98 and LN229 glioma cells were incubated with the newly developed liposomes and subsequently irradiated at the thermal column of the TRIGA reactor in Mainz. The dose rate derived from neutron irradiation with (157)Gd as neutron capturing agent was calculated via Monte Carlo simulations and set in relation to the respective cell survival. The liposomal Gd-DTPA reduced cell survival of F98 and LN229 cells significantly. Differences in liposomal composition of the formulations led to distinctly different outcome in cell survival. The amount of cellular Gd was not at all times proportional to cell survival, indicating that intracellular deposition of formulated Gd has a major influence on cell survival. The majority of the dose contribution arises from photon cross irradiation compared to a very small Gd-related dose. Liposomal gadolinium formulations represent a promising approach for neutron capture therapy of glioblastoma cells. The liposome composition determines the uptake and the survival of cells following radiation, presumably due to different uptake pathways of liposomes and intracellular deposition of gadolinium-DTPA. Due to the small range of the Auger and conversion electrons produced in (157)Gd capture, the proximity of Gd-atoms to cellular DNA is a crucial factor for infliction of lethal damage. Furthermore, Gd-containing liposomes may be used as MRI contrast agents for diagnostic purposes and surveillance of tumor targeting, thus enabling a theranostic approach for tumor therapy.

  11. Conceptual design project: Accelerator complex for nuclear physics studies and boron neutron capture therapy application at the Yerevan Physics Institute (YerPhI) Yerevan, Armenia

    NASA Astrophysics Data System (ADS)

    Avagyan, R. H.; Kerobyan, I. A.

    2015-07-01

    The final goal of the proposed project is the creation of a Complex of Accelerator Facilities at the Yerevan Physics Institute (CAF YerPhI) for nuclear physics basic researches, as well as for applied programs including boron neutron capture therapy (BNCT). The CAF will include the following facilities: Cyclotron C70, heavy material (uranium) target/ion source, mass-separator, LINAC1 (0.15-1.5 MeV/u) and LINAC2 (1.5-10 MeV/u). The delivered by C70 proton beams with energy 70 MeV will be used for investigations in the field of basic nuclear physics and with energy 30 MeV for use in applications.

  12. Workshop on neutron capture therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fairchild, R.G.; Bond, V.P.

    1986-01-01

    Potentially optimal conditions for Neutron Capture Therapy (NCT) may soon be in hand due to the anticipated development of band-pass filtered beams relatively free of fast neutron contaminations, and of broadly applicable biomolecules for boron transport such as porphyrins and monoclonal antibodies. Consequently, a number of groups in the US are now devoting their efforts to exploring NCT for clinical application. The purpose of this Workshop was to bring these groups together to exchange views on significant problems of mutual interest, and to assure a unified and effective approach to the solutions. Several areas of preclinical investigation were deemed tomore » be necessary before it would be possible to initiate clinical studies. As neither the monomer nor the dimer of sulfhydryl boron hydride is unequivocally preferable at this time, studies on both compounds should be continued until one is proven superior.« less

  13. Evaluation of a Gait Assessment Module Using 3D Motion Capture Technology

    PubMed Central

    Baskwill, Amanda J.; Belli, Patricia; Kelleher, Leila

    2017-01-01

    Background Gait analysis is the study of human locomotion. In massage therapy, this observation is part of an assessment process that informs treatment planning. Massage therapy students must apply the theory of gait assessment to simulated patients. At Humber College, the gait assessment module traditionally consists of a textbook reading and a three-hour, in-class session in which students perform gait assessment on each other. In 2015, Humber College acquired a three-dimensional motion capture system. Purpose The purpose was to evaluate the use of 3D motion capture in a gait assessment module compared to the traditional gait assessment module. Participants Semester 2 massage therapy students who were enrolled in Massage Theory 2 (n = 38). Research Design Quasi-experimental, wait-list comparison study. Intervention The intervention group participated in an in-class session with a Qualisys motion capture system. Main Outcome Measure(s) The outcomes included knowledge and application of gait assessment theory as measured by quizzes, and students’ satisfaction as measured through a questionnaire. Results There were no statistically significant differences in baseline and post-module knowledge between both groups (pre-module: p = .46; post-module: p = .63). There was also no difference between groups on the final application question (p = .13). The intervention group enjoyed the in-class session because they could visualize the content, whereas the comparison group enjoyed the interactivity of the session. The intervention group recommended adding the assessment of gait on their classmates to their experience. Both groups noted more time was needed for the gait assessment module. Conclusions Based on the results of this study, it is recommended that the gait assessment module combine both the traditional in-class session and the 3D motion capture system. PMID:28293329

  14. Application of an ultraminiature thermal neutron monitor for irradiation field study of accelerator-based neutron capture therapy

    PubMed Central

    Ishikawa, Masayori; Tanaka, Kenichi; Endo, Satrou; Hoshi, Masaharu

    2015-01-01

    Abstract Phantom experiments to evaluate thermal neutron flux distribution were performed using the Scintillator with Optical Fiber (SOF) detector, which was developed as a thermal neutron monitor during boron neutron capture therapy (BNCT) irradiation. Compared with the gold wire activation method and Monte Carlo N-particle (MCNP) calculations, it was confirmed that the SOF detector is capable of measuring thermal neutron flux as low as 105 n/cm2/s with sufficient accuracy. The SOF detector will be useful for phantom experiments with BNCT neutron fields from low-current accelerator-based neutron sources. PMID:25589504

  15. Microdosimetry: Principles and applications

    PubMed Central

    Santa Cruz, Gustavo A.

    2016-01-01

    Aim to present the most important aspects of Microdosimetry, a research field in radiation biophysics. Background microdosimetry is the branch of radiation biophysics that systematically studies the spatial, temporal and spectral aspects of the stochastic nature of the energy deposition processes in microscopic structures. Materials and Methods we briefly review its history, the people, the formalism and the theories and devices that allowed researchers to begin to understand the true nature of radiation action on living matter. Results and Conclusions we outline some of its applications, especially to Boron Neutron Capture Therapy, attempting to explain the biological effectiveness of the boron thermal neutron capture reaction. PMID:26933397

  16. Neutron-beam-shaping assembly for boron neutron-capture therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zaidi, L.; Kashaeva, E. A.; Lezhnin, S. I.

    A neutron-beam-shaping assembly consisting of a moderator, a reflector, and an absorber is used to form a therapeutic neutron beam for the boron neutron-capture therapy of malignant tumors at accelerator neutron sources. A new structure of the moderator and reflector is proposed in the present article, and the results of a numerical simulation of the neutron spectrum and of the absorbed dose in a modified Snyder head phantom are presented. The application of a composite moderator and of a composite reflector and the implementation of neutron production at the proton energy of 2.3MeV are shown to permit obtaining a high-qualitymore » therapeutic neutron beam.« less

  17. Single step synthesis of nanostructured boron nitride for boron neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Singh, Bikramjeet; Singh, Paviter; Kumar, Manjeet; Thakur, Anup; Kumar, Akshay

    2015-05-01

    Nanostructured Boron Nitride (BN) has been successfully synthesized by carbo-thermic reduction of Boric Acid (H3BO3). This method is a relatively low temperature synthesis route and it can be used for large scale production of nanostructured BN. The synthesized nanoparticles have been characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) and differential thermal analyzer (DTA). XRD analysis confirmed the formation of single phase nanostructured Boron Nitride. SEM analysis showed that the particles are spherical in shape. DTA analysis showed that the phase is stable upto 900 °C and the material can be used for high temperature applications as well boron neutron capture therapy (BNCT).

  18. Boron neutron capture therapy: Moving toward targeted cancer therapy.

    PubMed

    Mirzaei, Hamid Reza; Sahebkar, Amirhossein; Salehi, Rasoul; Nahand, Javid Sadri; Karimi, Ehsan; Jaafari, Mahmoud Reza; Mirzaei, Hamed

    2016-01-01

    Boron neutron capture therapy (BNCT) occurs when a stable isotope, boton-10, is irradiated with low-energy thermal neutrons to yield stripped down helium-4 nuclei and lithium-7 nuclei. It is a binary therapy in the treatment of cancer in which a cytotoxic event is triggered when an atom placed in a cancer cell. Here, we provide an overview on the application of BNCT in cancer therapy as well as current preclinical and clinical evidence on the efficacy of BNCT in the treatment of melanoma, brain tumors, head and neck cancer, and thyroid cancer. Several studies have shown that BNCT is effective in patients who had been treated with a full dose of conventional radiotherapy, because of its selectivity. In addition, BNCT is dependent on the normal/tumor tissue ratio of boron distribution. Increasing evidence has shown that BNCT can be combined with different drug delivery systems to enhance the delivery of boron to cancer cells. The flexibility of BNCT to be used in combination with different tumor-targeting approaches has made this strategy a promising option for cancer therapy. This review aims to provide a state-of-the-art overview of the recent advances in the use of BNCT for targeted therapy of cancer.

  19. Aptamer functionalized noble metal particles for bioanalytical and biomedical applications

    NASA Astrophysics Data System (ADS)

    Yasun, Emir

    Noble metal particles, especially gold (Au) and silver (Ag) have been exploited in a broad range of biological applications due to their unique intrinsic features that depend on their physical appearance or optoelectronic properties, which can be tuned with the change in the size or shape of those particles. Thus, this tunability enables gold nanoparticles (AuNPs) to be used in biomedical diagnostic and therapeutical applications. In photothermal therapy applications, nanomaterials, which can absorb efficiently in NIR region, are utilized since the healthy tissue or cells can't absorb at this spectral region. Among AuNPs, gold nanorods (AuNRs) are one of the best candidates for hyperthermia therapy of cancer cells with their high absorption cross-sections and tunable absorption maxima in NIR region. When this unique optical property is combined with the specificity against cancer cells utilized by aptamer conjugations, AuNRs become to be one of the most important nanoparticles employed in both cancer cell sensing and therapy. However, one drawback of AuNRs is having the surfactant CTAB on their surface, which can cause nonspecificity and cytotoxicity. In this research, the side effects of CTAB are passivated by BSA modification, where the nonspecificity and cytotoxicity are dramatically decreased prior to the NIR treatment. Recognition of changes in the rare cancer protein abundances can lead the early diagnosis of cancer, so capturing these low abundance proteins has a great significance. In this research, firstly, aptamer conjugated AuNRs were used to capture 1ng of a-thrombin effectively from plasma samples as model system. Then both aptamer conjugated AuNRs and silver microspheres (SMSs) are used to capture the biomarker proteins of a colon cancer cell line, DLD-1. Gold and silver surfaces can easily be modified through thiolate chemistry, compared to the tedious modification steps for the magnetic particles, so more aptamer immobilization can be achieved for AuNRs and SMSs, which can increase the possibility of binding to the target protein. Furthermore, SMSs offer a novel separation method, gravitational separation owing to their heavy nature. In this way, there is no need for an external stimuli to separate the captured proteins and protein isolation can take only seconds.

  20. Single step synthesis of nanostructured boron nitride for boron neutron capture therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Bikramjeet; Singh, Paviter; Kumar, Akshay, E-mail: akshaykumar.tiet@gmail.com

    2015-05-15

    Nanostructured Boron Nitride (BN) has been successfully synthesized by carbo-thermic reduction of Boric Acid (H{sub 3}BO{sub 3}). This method is a relatively low temperature synthesis route and it can be used for large scale production of nanostructured BN. The synthesized nanoparticles have been characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) and differential thermal analyzer (DTA). XRD analysis confirmed the formation of single phase nanostructured Boron Nitride. SEM analysis showed that the particles are spherical in shape. DTA analysis showed that the phase is stable upto 900 °C and the material can be used for high temperature applications asmore » well boron neutron capture therapy (BNCT)« less

  1. A comparison of the COG and MCNP codes in computational neutron capture therapy modeling, Part I: boron neutron capture therapy models.

    PubMed

    Culbertson, C N; Wangerin, K; Ghandourah, E; Jevremovic, T

    2005-08-01

    The goal of this study was to evaluate the COG Monte Carlo radiation transport code, developed and tested by Lawrence Livermore National Laboratory, for neutron capture therapy related modeling. A boron neutron capture therapy model was analyzed comparing COG calculational results to results from the widely used MCNP4B (Monte Carlo N-Particle) transport code. The approach for computing neutron fluence rate and each dose component relevant in boron neutron capture therapy is described, and calculated values are shown in detail. The differences between the COG and MCNP predictions are qualified and quantified. The differences are generally small and suggest that the COG code can be applied for BNCT research related problems.

  2. Tetrakis(p-carboranylthio-tetrafluorophenyl)chlorin (TPFC): application for photodynamic therapy and boron neutron capture therapy.

    PubMed

    Hiramatsu, Ryo; Kawabata, Shinji; Tanaka, Hiroki; Sakurai, Yoshinori; Suzuki, Minoru; Ono, Koji; Miyatake, Shin-ichi; Kuroiwa, Toshihiko; Hao, Erhong; Vicente, M Graça H

    2015-03-01

    Carboranyl-containing chlorins have emerged as promising dual sensitizers for use in both photodynamic therapy (PDT) and boron neutron capture therapy (BNCT), by virtue of their known tumor affinity, low cytotoxicity in dark conditions, and their strong absorptions in the red region of the optical spectrum. Tetrakis(p-carboranylthio-tetrafluorophenyl)chlorin (TPFC) is a new synthetic carboranyl-containing chlorin of high boron content (24% by weight). To evaluate TPFC's applicability as sensitizer for both PDT and BNCT, we performed an in vitro and in vivo study using F98 rat glioma cells and F98 rat glioma-bearing brain tumor models. For the in vivo BNCT study, we used boronophenylalanine (BPA), which is currently used in clinical BNCT studies, via intravenous administration (i.v.) and/or used TPFC via convection-enhanced delivery (CED), a method for local drug infusion directly into the brain. In the in vitro PDT study, the cell surviving fraction following laser irradiation (9 J/cm(2) ) was 0.035 whereas in the in vitro BNCT study, the cell surviving fraction following neutron irradiation (thermal neutron = 1.73 × 10(12) n/cm(2) ) was 0.04. In the in vivo BNCT study, the median survival time following concomitant administration of BPA (i.v.) and TPFC (CED) was 42 days (95% confidence interval; 37-43 days). © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  3. Tetrakis(p-Carboranylthio-Tetrafluorophenyl)Chlorin (TPFC): Application for Photodynamic Therapy and Boron Neutron Capture Therapy

    PubMed Central

    HIRAMATSU, RYO; KAWABATA, SHINJI; TANAKA, HIROKI; SAKURAI, YOSHINORI; SUZUKI, MINORU; ONO, KOJI; MIYATAKE, SHIN-ICHI; KUROIWA, TOSHIHIKO; HAO, ERHONG; VICENTE, M. GRAÇA H.

    2015-01-01

    Carboranyl-containing chlorins have emerged as promising dual sensitizers for use in both photodynamic therapy (PDT) and boron neutron capture therapy (BNCT), by virtue of their known tumor affinity, low cytotoxicity in dark conditions, and their strong absorptions in the red region of the optical spectrum. Tetrakis(p-carboranylthio-tetrafluorophenyl)chlorin (TPFC) is a new synthetic carboranyl-containing chlorin of high boron content (24% by weight). To evaluate TPFC’s applicability as sensitizer for both PDT and BNCT, we performed an in vitro and in vivo study using F98 rat glioma cells and F98 rat glioma-bearing brain tumor models. For the in vivo BNCT study, we used boronophenylalanine (BPA), which is currently used in clinical BNCT studies, via intravenous administration (i.v.) and/or used TPFC via convection-enhanced delivery (CED), a method for local drug infusion directly into the brain. In the in vitro PDT study, the cell surviving fraction following laser irradiation (9 J/cm2) was 0.035 whereas in the in vitro BNCT study, the cell surviving fraction following neutron irradiation (thermal neutron = 1.73 × 1012 n/cm2) was 0.04. In the in vivo BNCT study, the median survival time following concomitant administration of BPA (i.v.) and TPFC (CED) was 42 days (95% confidence interval; 37–43 days). PMID:25546823

  4. Universal algorithm for diagnosis of biventricular capture in patients with cardiac resynchronization therapy.

    PubMed

    Jastrzebski, Marek; Kukla, Piotr; Fijorek, Kamil; Czarnecka, Danuta

    2014-08-01

    An accurate and universal method for diagnosis of biventricular (BiV) capture using a standard 12-lead electrocardiogram (ECG) would be useful for assessment of cardiac resynchronization therapy (CRT) patients. Our objective was to develop and validate such an ECG method for BiV capture diagnosis that would be independent of pacing lead positions-a major confounder that significantly influences the morphologies of paced QRS complexes. On the basis of an evaluation of 789 ECGs of 443 patients with heart failure and various right ventricular (RV) and left ventricular (LV) lead positions, the following algorithm was constructed and validated. BiV capture was diagnosed if the QRS in lead I was predominantly negative and either V1 QRS was predominantly positive or V6 QRS was of negative onset and predominantly negative (step 1), or if QRS complex duration was <160 ms (step 2). All other ECGs were classified as loss of LV capture. The algorithm showed good accuracy (93%), sensitivity (97%), and specificity (90%) for detection of loss of LV capture. The performance of the algorithm did not differ among apical, midseptal, and outflow tract RV lead positions and various LV lead positions. LV capture leaves diagnostic hallmarks in the fused BiV QRS related to different vectors of depolarization and more rapid depolarization of the ventricles. An accurate two-step ECG algorithm for BiV capture diagnosis was developed and validated. This algorithm is universally applicable to all CRT patients, regardless of the positions of the pacing leads. ©2014 Wiley Periodicals, Inc.

  5. Ultra-fast electron capture by electrosterically-stabilized gold nanoparticles.

    PubMed

    Ghandi, Khashayar; Findlater, Alexander D; Mahimwalla, Zahid; MacNeil, Connor S; Awoonor-Williams, Ernest; Zahariev, Federico; Gordon, Mark S

    2015-07-21

    Ultra-fast pre-solvated electron capture has been observed for aqueous solutions of room-temperature ionic liquid (RTIL) surface-stabilized gold nanoparticles (AuNPs; ∼9 nm). The extraordinarily large inverse temperature dependent rate constants (k(e)∼ 5 × 10(14) M(-1) s(-1)) measured for the capture of electrons in solution suggest electron capture by the AuNP surface that is on the timescale of, and therefore in competition with, electron solvation and electron-cation recombination reactions. The observed electron transfer rates challenge the conventional notion that radiation induced biological damage would be enhanced in the presence of AuNPs. On the contrary, AuNPs stabilized by non-covalently bonded ligands demonstrate the potential to quench radiation-induced electrons, indicating potential applications in fields ranging from radiation therapy to heterogeneous catalysis.

  6. 3DUI assisted lower and upper member therapy.

    PubMed

    Uribe-Quevedo, Alvaro; Perez-Gutierrez, Byron

    2012-01-01

    3DUIs are becoming very popular among researchers, developers and users as they allow more immersive and interactive experiences by taking advantage of the human dexterity. The features offered by these interfaces outside the gaming environment, have allowed the development of applications in the medical area by enhancing the user experience and aiding the therapy process in controlled and monitored environments. Using mainstream videogame 3DUIs based on inertial and image sensors available in the market, this work presents the development of a virtual environment and its navigation through lower member captured gestures for assisting motion during therapy.

  7. Characteristics of a heavy water photoneutron source in boron neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Danial, Salehi; Dariush, Sardari; M. Salehi, Jozani

    2013-07-01

    Bremsstrahlung photon beams produced by medical linear accelerators are currently the most commonly used method of radiation therapy for cancerous tumors. Photons with energies greater than 8-10 MeV potentially generate neutrons through photonuclear interactions in the accelerator's treatment head, patient's body, and treatment room ambient. Electrons impinging on a heavy target generate a cascade shower of bremsstrahlung photons, the energy spectrum of which shows an end point equal to the electron beam energy. By varying the target thickness, an optimum thickness exists for which, at the given electron energy, maximum photon flux is achievable. If a source of high-energy photons i.e. bremsstrahlung, is conveniently directed to a suitable D2O target, a novel approach for production of an acceptable flux of filterable photoneturons for boron neutron capture therapy (BNCT) application is possible. This study consists of two parts. 1. Comparison and assessment of deuterium photonuclear cross section data. 2. Evaluation of the heavy water photonuclear source.

  8. Boron containing compounds and their preparation and use in neutron capture therapy

    DOEpatents

    Gabel, D.

    1992-09-01

    The present invention pertains to boron containing thiouracil derivatives, their method of preparations, and their use in the therapy of malignant melanoma using boron neutron capture therapy. No Drawings

  9. Boron analysis for neutron capture therapy using particle-induced gamma-ray emission.

    PubMed

    Nakai, Kei; Yamamoto, Yohei; Okamoto, Emiko; Yamamoto, Tetsuya; Yoshida, Fumiyo; Matsumura, Akira; Yamada, Naoto; Kitamura, Akane; Koka, Masashi; Satoh, Takahiro

    2015-12-01

    The neutron source of BNCT is currently changing from reactor to accelerator, but peripheral facilities such as a dose-planning system and blood boron analysis have still not been established. To evaluate the potential application of particle-induced gamma-ray emission (PIGE) for boron measurement in clinical boron neutron capture therapy, boronophenylalanine dissolved within a cell culture medium was measured using PIGE. PIGE detected 18 μgB/mL f-BPA in the culture medium, and all measurements of any given sample were taken within 20 min. Two hours of f-BPA exposure was required to create a boron distribution image. However, even though boron remained in the cells, the boron on the cell membrane could not be distinguished from the boron in the cytoplasm. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Application of an incident taxonomy for radiation therapy: Analysis of five years of data from three integrated cancer centres.

    PubMed

    Greenham, Stuart; Manley, Stephen; Turnbull, Kirsty; Hoffmann, Matthew; Fonseca, Amara; Westhuyzen, Justin; Last, Andrew; Aherne, Noel J; Shakespeare, Thomas P

    2018-01-01

    To develop and apply a clinical incident taxonomy for radiation therapy. Capturing clinical incident information that focuses on near-miss events is critical for achieving higher levels of safety and reliability. A clinical incident taxonomy for radiation therapy was established; coding categories were prescription, consent, simulation, voluming, dosimetry, treatment, bolus, shielding, imaging, quality assurance and coordination of care. The taxonomy was applied to all clinical incidents occurring at three integrated cancer centres for the years 2011-2015. Incidents were managed locally, audited and feedback disseminated to all centres. Across the five years the total incident rate (per 100 courses) was 8.54; the radiotherapy-specific coded rate was 6.71. The rate of true adverse events (unintended treatment and potential patient harm) was 1.06. Adverse events, where no harm was identified, occurred at a rate of 2.76 per 100 courses. Despite workload increases, overall and actual rates both exhibited downward trends over the 5-year period. The taxonomy captured previously unidentified quality assurance failures; centre-specific issues that contributed to variations in incident trends were also identified. The application of a taxonomy developed for radiation therapy enhances incident investigation and facilitates strategic interventions. The practice appears to be effective in our institution and contributes to the safety culture. The ratio of near miss to actual incidents could serve as a possible measure of incident reporting culture and could be incorporated into large scale incident reporting systems.

  11. Neutron capture therapy: Years of experimentation---Years of reflection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farr, L.E.

    1991-12-16

    This report describes early research on neutron capture therapy over a number of years, beginning in 1950, speaking briefly of patient treatments but dwelling mostly on interpretations of our animal experiments. This work carried out over eighteen years, beginning over forty years ago. Yet, it is only fitting to start by relating how neutron capture therapy became part of Brookhaven`s Medical Research Center program.

  12. Neutron capture therapy: Years of experimentation---Years of reflection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farr, L.E.

    1991-12-16

    This report describes early research on neutron capture therapy over a number of years, beginning in 1950, speaking briefly of patient treatments but dwelling mostly on interpretations of our animal experiments. This work carried out over eighteen years, beginning over forty years ago. Yet, it is only fitting to start by relating how neutron capture therapy became part of Brookhaven's Medical Research Center program.

  13. Boron Neutron Capture Therapy for Malignant Brain Tumors

    PubMed Central

    MIYATAKE, Shin-Ichi; KAWABATA, Shinji; HIRAMATSU, Ryo; KUROIWA, Toshihiko; SUZUKI, Minoru; KONDO, Natsuko; ONO, Koji

    2016-01-01

    Boron neutron capture therapy (BNCT) is a biochemically targeted radiotherapy based on the nuclear capture and fission reactions that occur when non-radioactive boron-10, which is a constituent of natural elemental boron, is irradiated with low energy thermal neutrons to yield high linear energy transfer alpha particles and recoiling lithium-7 nuclei. Therefore, BNCT enables the application of a high dose of particle radiation selectively to tumor cells in which boron-10 compound has been accumulated. We applied BNCT using nuclear reactors for 167 cases of malignant brain tumors, including recurrent malignant gliomas, newly diagnosed malignant gliomas, and recurrent high-grade meningiomas from January 2002 to May 2014. Here, we review the principle and history of BNCT. In addition, we introduce fluoride-18-labeled boronophenylalanine positron emission tomography and the clinical results of BNCT for the above-mentioned malignant brain tumors. Finally, we discuss the recent development of accelerators producing epithermal neutron beams. This development could provide an alternative to the current use of specially modified nuclear reactors as a neutron source, and could allow BNCT to be performed in a hospital setting. PMID:27250576

  14. Boron Neutron Capture Therapy for Malignant Brain Tumors.

    PubMed

    Miyatake, Shin-Ichi; Kawabata, Shinji; Hiramatsu, Ryo; Kuroiwa, Toshihiko; Suzuki, Minoru; Kondo, Natsuko; Ono, Koji

    2016-07-15

    Boron neutron capture therapy (BNCT) is a biochemically targeted radiotherapy based on the nuclear capture and fission reactions that occur when non-radioactive boron-10, which is a constituent of natural elemental boron, is irradiated with low energy thermal neutrons to yield high linear energy transfer alpha particles and recoiling lithium-7 nuclei. Therefore, BNCT enables the application of a high dose of particle radiation selectively to tumor cells in which boron-10 compound has been accumulated. We applied BNCT using nuclear reactors for 167 cases of malignant brain tumors, including recurrent malignant gliomas, newly diagnosed malignant gliomas, and recurrent high-grade meningiomas from January 2002 to May 2014. Here, we review the principle and history of BNCT. In addition, we introduce fluoride-18-labeled boronophenylalanine positron emission tomography and the clinical results of BNCT for the above-mentioned malignant brain tumors. Finally, we discuss the recent development of accelerators producing epithermal neutron beams. This development could provide an alternative to the current use of specially modified nuclear reactors as a neutron source, and could allow BNCT to be performed in a hospital setting.

  15. Thiourea derivatives, methods of their preparation and their use in neutron capture therapy of malignant melanoma

    DOEpatents

    Gabel, D.

    1991-06-04

    The present invention pertains to boron containing thiouracil derivatives, their method of preparations, and their use in the therapy of malignant melanoma using boron neutron capture therapy. No Drawings

  16. Comparison between proton boron fusion therapy (PBFT) and boron neutron capture therapy (BNCT): a monte carlo study.

    PubMed

    Jung, Joo-Young; Yoon, Do-Kun; Barraclough, Brendan; Lee, Heui Chang; Suh, Tae Suk; Lu, Bo

    2017-06-13

    The aim of this study is to compare between proton boron fusion therapy (PBFT) and boron neutron capture therapy (BNCT) and to analyze dose escalation using a Monte Carlo simulation. We simulated a proton beam passing through the water with a boron uptake region (BUR) in MCNPX. To estimate the interaction between neutrons/protons and borons by the alpha particle, the simulation yielded with a variation of the center of the BUR location and proton energies. The variation and influence about the alpha particle were observed from the percent depth dose (PDD) and cross-plane dose profile of both the neutron and proton beams. The peak value of the maximum dose level when the boron particle was accurately labeled at the region was 192.4% among the energies. In all, we confirmed that prompt gamma rays of 478 keV and 719 keV were generated by the nuclear reactions in PBFT and BNCT, respectively. We validated the dramatic effectiveness of the alpha particle, especially in PBFT. The utility of PBFT was verified using the simulation and it has a potential for application in radiotherapy.

  17. Comparison between proton boron fusion therapy (PBFT) and boron neutron capture therapy (BNCT): a Monte Carlo study

    PubMed Central

    Barraclough, Brendan; Lee, Heui Chang; Suh, Tae Suk; Lu, Bo

    2017-01-01

    The aim of this study is to compare between proton boron fusion therapy (PBFT) and boron neutron capture therapy (BNCT) and to analyze dose escalation using a Monte Carlo simulation. We simulated a proton beam passing through the water with a boron uptake region (BUR) in MCNPX. To estimate the interaction between neutrons/protons and borons by the alpha particle, the simulation yielded with a variation of the center of the BUR location and proton energies. The variation and influence about the alpha particle were observed from the percent depth dose (PDD) and cross-plane dose profile of both the neutron and proton beams. The peak value of the maximum dose level when the boron particle was accurately labeled at the region was 192.4% among the energies. In all, we confirmed that prompt gamma rays of 478 keV and 719 keV were generated by the nuclear reactions in PBFT and BNCT, respectively. We validated the dramatic effectiveness of the alpha particle, especially in PBFT. The utility of PBFT was verified using the simulation and it has a potential for application in radiotherapy. PMID:28427153

  18. Design and development of an upper extremity motion capture system for a rehabilitation robot.

    PubMed

    Nanda, Pooja; Smith, Alan; Gebregiorgis, Adey; Brown, Edward E

    2009-01-01

    Human robot interaction is a new and rapidly growing field and its application in the realm of rehabilitation and physical care is a major focus area of research worldwide. This paper discusses the development and implementation of a wireless motion capture system for the human arm which can be used for physical therapy or real-time control of a robotic arm, among many other potential applications. The system is comprised of a mechanical brace with rotary potentiometers inserted at the different joints to capture position data. It also contains surface electrodes which acquire electromyographic signals through the CleveMed BioRadio device. The brace interfaces with a software subsystem which displays real time data signals. The software includes a 3D arm model which imitates the actual movement of a subject's arm under testing. This project began as part of the Rochester Institute of Technology's Undergraduate Multidisciplinary Senior Design curriculum and has been integrated into the overall research objectives of the Biomechatronic Learning Laboratory.

  19. Synthesis of boron nitride nanotubes and their applications

    PubMed Central

    Kalay, Saban; Yilmaz, Zehra; Sen, Ozlem; Emanet, Melis; Kazanc, Emine

    2015-01-01

    Summary Boron nitride nanotubes (BNNTs) have been increasingly investigated for use in a wide range of applications due to their unique physicochemical properties including high hydrophobicity, heat and electrical insulation, resistance to oxidation, and hydrogen storage capacity. They are also valued for their possible medical and biomedical applications including drug delivery, use in biomaterials, and neutron capture therapy. In this review, BNNT synthesis methods and the surface modification strategies are first discussed, and then their toxicity and application studies are summarized. Finally, a perspective for the future use of these novel materials is discussed. PMID:25671154

  20. Gadolinium as a Neutron Capture Therapy Agent

    NASA Astrophysics Data System (ADS)

    Shih, Jing-Luen Allen

    The clinical results of treating brain tumors with boron neutron capture therapy are very encouraging and researchers around the world are once again making efforts to develop this therapeutic modality. Boron-10 is the agent receiving the most attention for neutron capture therapy but ^{157}Gd is a nuclide that also holds interesting properties of being a neutron capture therapy agent. The objective of this study is to evaluate ^{157}Gd as a neutron capture therapy agent. In this study it is determined that tumor concentrations of about 300 mug ^{157}Gd/g tumor can be achieved in brain tumors with some FDA approved MRI contrast agents such as Gd-DTPA and Gd-DOTA, and up to 628 mug ^{157 }Gd/g tumor can be established in bone tumors with Gd-EDTMP. Monte Carlo calculations show that with only 250 ppm of ^{157}Gd in tumor, neutron capture therapy can deliver 2,000 cGy to a tumor of 2 cm diameter or larger with 5 times 10^{12} n/cm ^2 fluence at the tumor. Dose measurements which were made with films and TLD's in phantoms verified these calculations. More extended Monte Carlo calculations demonstrate that neutron capture therapy with Gd possesses comparable dose distribution to B neutron capture therapy. With 5 times 10^{12 } n/cm^2 thermal neutrons at the tumor, Auger electrons from the Gd produced an optical density enhancement on the films that is similar to the effect caused by about 300 cGy of Gd prompt gamma dose which will further enhance the therapeutic effects. A technique that combines brachytherapy with Gd neutron capture therapy has been evaluated. Monte Carlo calculations show that 5,000 cGy of prompt gamma dose can be delivered to a treatment volume of 40 cm^3 with a 3-plane implant of a total of 9 Gd needles. The tumor to normal tissue advantage of this method is as good as ^{60} Co brachytherapy. Measurements of prompt gamma dose with films and TLD-700's in a lucite phantom verify the Monte Carlo evaluation. A technique which displays the Gd distribution and its relative concentration in samples has been developed. Concentrations of ^{157}Gd in samples range from 20 ppm to 500 ppm can be determined with this technique. The intrinsic spatial resolution of the imaging system in 70 mum.

  1. Approach to magnetic neutron capture therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuznetsov, Anatoly A.; Podoynitsyn, Sergey N.; Filippov, Victor I.

    2005-11-01

    Purpose: The method of magnetic neutron capture therapy can be described as a combination of two methods: magnetic localization of drugs using magnetically targeted carriers and neutron capture therapy itself. Methods and Materials: In this work, we produced and tested two types of particles for such therapy. Composite ultradispersed ferro-carbon (Fe-C) and iron-boron (Fe-B) particles were formed from vapors of respective materials. Results: Two-component ultradispersed particles, containing Fe and C, were tested as magnetic adsorbent of L-boronophenylalanine and borax and were shown that borax sorption could be effective for creation of high concentration of boron atoms in the area ofmore » tumor. Kinetics of boron release into the physiologic solution demonstrate that ultradispersed Fe-B (10%) could be applied for an effective magnetic neutron capture therapy. Conclusion: Both types of the particles have high magnetization and magnetic homogeneity, allow to form stable magnetic suspensions, and have low toxicity.« less

  2. Subcellular SIMS imaging of gadolinium isotopes in human glioblastoma cells treated with a gadolinium containing MRI agent

    NASA Astrophysics Data System (ADS)

    Smith, Duane R.; Lorey, Daniel R.; Chandra, Subhash

    2004-06-01

    Neutron capture therapy is an experimental binary radiotherapeutic modality for the treatment of brain tumors such as glioblastoma multiforme. Recently, neutron capture therapy with gadolinium-157 has gained attention, and techniques for studying the subcellular distribution of gadolinium-157 are needed. In this preliminary study, we have been able to image the subcellular distribution of gadolinium-157, as well as the other six naturally abundant isotopes of gadolinium, with SIMS ion microscopy. T98G human glioblastoma cells were treated for 24 h with 25 mg/ml of the metal ion complex diethylenetriaminepentaacetic acid Gd(III) dihydrogen salt hydrate (Gd-DTPA). Gd-DTPA is a contrast enhancing agent used for MRI of brain tumors, blood-brain barrier impairment, diseases of the central nervous system, etc. A highly heterogeneous subcellular distribution was observed for gadolinium-157. The nuclei in each cell were distinctly lower in gadolinium-157 than in the cytoplasm. Even within the cytoplasm the gadolinium-157 was heterogeneously distributed. The other six naturally abundant isotopes of gadolinium were imaged from the same cells and exhibited a subcellular distribution consistent with that observed for gadolinium-157. These observations indicate that SIMS ion microscopy may be a viable approach for subcellular studies of gadolinium containing neutron capture therapy drugs and may even play a major role in the development and validation of new gadolinium contrast enhancing agents for diagnostic MRI applications.

  3. Boron Neutron Capture Therapy (BNCT) in an oral precancer model: therapeutic benefits and potential toxicity of a double application of BNCT with a six-week interval.

    PubMed

    Monti Hughes, Andrea; Pozzi, Emiliano C C; Heber, Elisa M; Thorp, Silvia; Miller, Marcelo; Itoiz, Maria E; Aromando, Romina F; Molinari, Ana J; Garabalino, Marcela A; Nigg, David W; Trivillin, Verónica A; Schwint, Amanda E

    2011-11-01

    Given the clinical relevance of locoregional recurrences in head and neck cancer, we developed a novel experimental model of premalignant tissue in the hamster cheek pouch for long-term studies and demonstrated the partial inhibitory effect of a single application of Boron Neutron Capture Therapy (BNCT) on tumor development from premalignant tissue. The aim of the present study was to evaluate the effect of a double application of BNCT with a 6 week interval in terms of inhibitory effect on tumor development, toxicity and DNA synthesis. We performed a double application, 6 weeks apart, of (1) BNCT mediated by boronophenylalanine (BPA-BNCT); (2) BNCT mediated by the combined application of decahydrodecaborate (GB-10) and BPA [(GB-10+BPA)-BNCT] or (3) beam-only, at RA-3 nuclear reactor and followed the animals for 8 months. The control group was cancerized and sham-irradiated. BPA-BNCT, (GB-10+BPA)-BNCT and beam-only induced a reduction in tumor development from premalignant tissue that persisted until 8, 3, and 2 months respectively. An early maximum inhibition of 100% was observed for all 3 protocols. No normal tissue radiotoxicity was detected. Reversible mucositis was observed in premalignant tissue, peaking at 1 week and resolving by the third week after each irradiation. Mucositis after the second application was not exacerbated by the first application. DNA synthesis was significantly reduced in premalignant tissue 8 months post-BNCT. A double application of BPA-BNCT and (GB-10+BPA)-BNCT, 6 weeks apart, could be used therapeutically at no additional cost in terms of radiotoxicity in normal and dose-limiting tissues. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Dendrimer-based nanoparticles for cancer therapy.

    PubMed

    Baker, James R

    2009-01-01

    Recent work has suggested that nanoparticles in the form of dendrimers may be a keystone in the future of therapeutics. The field of oncology could soon be revolutionized by novel strategies for diagnosis and therapy employing dendrimer-based nanotherapeutics. Several aspects of cancer therapy would be involved. Diagnosis using imaging techniques such as MRI will be improved by the incorporation of dendrimers as advanced contrast agents. This might involve novel contrast agents targeted specifically to cancer cells. Dendrimers can also be being applied to a variety of cancer therapies to improve their safety and efficacy. A strategy, somewhat akin to the "Trojan horse," involves targeting anti-metabolite drugs via vitamins or hormones that tumors need for growth. Further applications of dendrimers in photodynamic therapy, boron neutron capture therapy, and gene therapy for cancer are being examined. This presentation will cover the fundamentals of research utilizing dendrimers for cancer diagnosis and therapy. An evaluation of this new technologies will detail what advantage dendrimer based therapeutics might have over conventional cancer drugs.

  5. Clinical trials for treating recurrent head and neck cancer with boron neutron capture therapy using the Tsing-Hua Open Pool Reactor.

    PubMed

    Wang, Ling-Wei; Liu, Yen-Wan Hsueh; Chou, Fong-In; Jiang, Shiang-Huei

    2018-06-19

    Head and neck (HN) cancer is an endemic disease in Taiwan, China. Locally recurrent HN cancer after full-dose irradiation poses a therapeutic challenge, and boron neutron capture therapy (BNCT) may be a solution that could provide durable local control with tolerable toxicity. The Tsing-Hua Open Pool Reactor (THOR) at National Tsing-Hua University in Hsin-Chu, provides a high-quality epithermal neutron source for basic and clinical BNCT research. Our first clinical trial, entitled "A phase I/II trial of boron neutron capture therapy for recurrent head and neck cancer at THOR", was carried out between 2010 and 2013. A total of 17 patients with 23 recurrent HN tumors who had received high-dose photon irradiation were enrolled in the study. The fructose complex of L-boronophenylalanine was used as a boron carrier, and a two-fraction BNCT treatment regimen at 28-day intervals was used for each patient. Toxicity was acceptable, and although the response rate was high (12/17), re-recurrence within or near the radiation site was common. To obtain better local control, another clinical trial entitled "A phase I/II trial of boron neutron capture therapy combined with image-guided intensity-modulated radiotherapy (IG-IMRT) for locally recurrent HN cancer" was initiated in 2014. The first administration of BNCT was performed according to our previous protocol, and IG-IMRT was initiated 28 days after BNCT. As of May 2017, seven patients have been treated with this combination. The treatment-related toxicity was similar to that previously observed with two BNCT applications. Three patients had a complete response, but locoregional recurrence was the major cause of failure despite initially good responses. Future clinical trials combining BNCT with other local or systemic treatments will be carried out for recurrent HN cancer patients at THOR.

  6. Laser Capture Microdissection in the Genomic and Proteomic Era: Targeting the Genetic Basis of Cancer

    PubMed Central

    Domazet, Barbara; MacLennan, Gregory T.; Lopez-Beltran, Antonio; Montironi, Rodolfo; Cheng, Liang

    2008-01-01

    The advent of new technologies has enabled deeper insight into processes atsubcellular levels, which will ultimately improve diagnostic procedures and patient outcome. Thanks to cell enrichment methods, it is now possible to study cells in their native environment. This has greatly contributed to a rapid growth in several areas, such as gene expression analysis, proteomics, and metabolonomics. Laser capture microdissection (LCM) as a method of procuring subpopulations of cells under direct visual inspection is playing an important role in these areas. This review provides an overview of existing LCM technology and its downstream applications in genomics, proteomics, diagnostics and therapy. PMID:18787684

  7. Laser capture microdissection in the genomic and proteomic era: targeting the genetic basis of cancer.

    PubMed

    Domazet, Barbara; Maclennan, Gregory T; Lopez-Beltran, Antonio; Montironi, Rodolfo; Cheng, Liang

    2008-03-15

    The advent of new technologies has enabled deeper insight into processes at subcellular levels, which will ultimately improve diagnostic procedures and patient outcome. Thanks to cell enrichment methods, it is now possible to study cells in their native environment. This has greatly contributed to a rapid growth in several areas, such as gene expression analysis, proteomics, and metabolonomics. Laser capture microdissection (LCM) as a method of procuring subpopulations of cells under direct visual inspection is playing an important role in these areas. This review provides an overview of existing LCM technology and its downstream applications in genomics, proteomics, diagnostics and therapy.

  8. Amphiphilic Polycarbonates from Carborane-Installed Cyclic Carbonates as Potential Agents for Boron Neutron Capture Therapy.

    PubMed

    Xiong, Hejian; Wei, Xing; Zhou, Dongfang; Qi, Yanxin; Xie, Zhigang; Chen, Xuesi; Jing, Xiabin; Huang, Yubin

    2016-09-21

    Carboranes with rich boron content have showed significant applications in the field of boron neutron capture therapy. Biodegradable derivatives of carborane-conjugated polymers with well-defined structure and tunable loading of boron atoms are far less explored. Herein, a new family of amphiphilic carborane-conjugated polycarbonates was synthesized by ring-opening polymerization of a carborane-installed cyclic carbonate monomer. Catalyzed by TBD from a poly(ethylene glycol) macroinitiator, the polymerization proceeded to relatively high conversions (>65%), with low polydispersity in a certain range of molecular weight. The boron content was readily tuned by the feed ratio of the monomer and initiator. The resultant amphiphilic polycarbonates self-assembled in water into spherical nanoparticles of different sizes depending on the hydrophilic-to-hydrophobic ratio. It was demonstrated that larger nanoparticles (PN150) were more easily subjected to protein adsorption and captured by the liver, and smaller nanoparticles (PN50) were more likely to enter cancer cells and accumulate at the tumor site. PN50 with thermal neutron irradiation exhibited the highest therapeutic efficacy in vivo. The new synthetic method utilizing amphiphilic biodegradable boron-enriched polymers is useful for developing more-selective and -effective boron delivery systems for BNCT.

  9. Topical Review: Polymer gel dosimetry

    PubMed Central

    Baldock, C; De Deene, Y; Doran, S; Ibbott, G; Jirasek, A; Lepage, M; McAuley, K B; Oldham, M; Schreiner, L J

    2010-01-01

    Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-dimensions (3D), have specific advantages when compared to one-dimensional dosimeters, such as ion chambers, and two-dimensional dosimeters, such as film. These advantages are particularly significant in dosimetry situations where steep dose gradients exist such as in intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery. Polymer gel dosimeters also have specific advantages for brachytherapy dosimetry. Potential dosimetry applications include those for low-energy x-rays, high-linear energy transfer (LET) and proton therapy, radionuclide and boron capture neutron therapy dosimetries. These 3D dosimeters are radiologically soft-tissue equivalent with properties that may be modified depending on the application. The 3D radiation dose distribution in polymer gel dosimeters may be imaged using magnetic resonance imaging (MRI), optical-computerized tomography (optical-CT), x-ray CT or ultrasound. The fundamental science underpinning polymer gel dosimetry is reviewed along with the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are also presented. PMID:20150687

  10. DEVELOPMENT OF A MULTIMODAL MONTE CARLO BASED TREATMENT PLANNING SYSTEM.

    PubMed

    Kumada, Hiroaki; Takada, Kenta; Sakurai, Yoshinori; Suzuki, Minoru; Takata, Takushi; Sakurai, Hideyuki; Matsumura, Akira; Sakae, Takeji

    2017-10-26

    To establish boron neutron capture therapy (BNCT), the University of Tsukuba is developing a treatment device and peripheral devices required in BNCT, such as a treatment planning system. We are developing a new multimodal Monte Carlo based treatment planning system (developing code: Tsukuba Plan). Tsukuba Plan allows for dose estimation in proton therapy, X-ray therapy and heavy ion therapy in addition to BNCT because the system employs PHITS as the Monte Carlo dose calculation engine. Regarding BNCT, several verifications of the system are being carried out for its practical usage. The verification results demonstrate that Tsukuba Plan allows for accurate estimation of thermal neutron flux and gamma-ray dose as fundamental radiations of dosimetry in BNCT. In addition to the practical use of Tsukuba Plan in BNCT, we are investigating its application to other radiation therapies. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Performance verification of an epithermal neutron flux monitor using accelerator-based BNCT neutron sources

    NASA Astrophysics Data System (ADS)

    Guan, X.; Murata, I.; Wang, T.

    2017-09-01

    The performance of an epithermal neutron flux monitor developed for boron neutron capture therapy (BNCT) is verified by Monte Carlo simulations using accelerator-based neutron sources (ABNSs). The results indicate that the developed epithermal neutron flux monitor works well and it can be efficiently used in practical applications to measure the epithermal neutron fluxes of ABNSs in a high accuracy.

  12. Biocompatibility of functionalized boron phosphate (BPO4) nanoparticles for boron neutron capture therapy (BNCT) application.

    PubMed

    Achilli, Cesare; Grandi, Stefania; Ciana, Annarita; Guidetti, Gianni F; Malara, Alessandro; Abbonante, Vittorio; Cansolino, Laura; Tomasi, Corrado; Balduini, Alessandra; Fagnoni, Maurizio; Merli, Daniele; Mustarelli, Piercarlo; Canobbio, Ilaria; Balduini, Cesare; Minetti, Giampaolo

    2014-04-01

    Boron neutron capture therapy (BNCT) is a radiotherapy treatment based on the accumulation in the tumor of a (10)B-containing drug and subsequent irradiation with low energy neutrons, which bring about the decay of (10)B to (7)Li and an α particle, causing the death of the neoplastic cell. The effectiveness of BNCT is limited by the low delivery and accumulation of the used boron-containing compounds. Here we report the development and the characterization of BPO4 nanoparticles (NPs) as a novel possible alternative drug for BNCT. An extensive analysis of BPO4 NP biocompatibility was performed using both mature blood cells (erythrocytes, neutrophils and platelets) and a model of hematopoietic progenitor cells. A time- and concentration-dependent cytotoxicity study was performed on neoplastic coloncarcinoma and osteosarcoma cell lines. BPO4 functionalization with folic acid, introduced to improve the uptake by tumor cells, appeared to effectively limit the unwanted effects of NPs on the analyzed blood components. Boron neutron capture therapy (BNCT) is a radiotherapy treatment modality based on the accumulation of a (10)B-containing drug and subsequent irradiation with low energy neutrons, inducing the decay of (10)B to (7)Li and an α particle, causing neoplastic cell death. This team of authors reports on a folic acid functionalized BPO4 nanoparticle with improved characteristics compared with conventional BNCT approaches, as demonstrated in tumor cell lines, and hopefully to be followed by translational human studies. © 2014.

  13. Quantitative bioimaging of p-boronophenylalanine in thin liver tissue sections as a tool for treatment planning in boron neutron capture therapy.

    PubMed

    Reifschneider, Olga; Schütz, Christian L; Brochhausen, Christoph; Hampel, Gabriele; Ross, Tobias; Sperling, Michael; Karst, Uwe

    2015-03-01

    An analytical method using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) was developed and applied to assess enrichment of 10B-containing p-boronophenylalanine-fructose (BPA-f) and its pharmacokinetic distribution in human tissues after application for boron neutron capture therapy (BNCT). High spatial resolution (50 μm) and limits of detection in the low parts-per-billion range were achieved using a Nd:YAG laser of 213 nm wavelength. External calibration by means of 10B-enriched standards based on whole blood proved to yield precise quantification results. Using this calibration method, quantification of 10B in cancerous and healthy tissue was carried out. Additionally, the distribution of 11B was investigated, providing 10B enrichment in the investigated tissues. Quantitative imaging of 10B by means of LA-ICP-MS was demonstrated as a new option to characterise the efficacy of boron compounds for BNCT.

  14. Halogenated sulfidohydroboranes for nuclear medicine and boron neutron capture therapy

    DOEpatents

    Miura, Michiko; Slatkin, Daniel N.

    1997-03-18

    A method for performing boron neutron capture therapy for the treatment of tumors is disclosed. The method includes administering to a patient an iodinated sulfidohydroborane, a boron-10-containing compound. The site of the tumor is localized by visualizing the increased concentration of the iodine labelled compound at the tumor. The targeted tumor is then irradiated with a beam of neutrons having an energy distribution effective for neutron capture. Destruction of the tumor occurs due to high LET particle irradiation of the tissue secondary to the incident neutrons being captured by the boron-10 nuclei. Iodinated sulfidohydroboranes are disclosed which are especially suitable for the method of the invention. In a preferred embodiment, a compound having the formula Na.sub.4 B.sub.12 I.sub.11 SSB.sub.12 I.sub.11, or another pharmaceutically acceptable salt of the compound, may be administered to a cancer patient for boron neutron capture therapy.

  15. Halogenated sulfidohydroboranes for nuclear medicine and boron neutron capture therapy

    DOEpatents

    Miura, Michiko; Slatkin, Daniel N.

    1995-10-03

    A method for performing boron neutron capture therapy for the treatment of tumors is disclosed. The method includes administering to a patient an iodinated sulfidohydroborane, a boron-10-containing compound. The site of the tumor is localized by visualizing the increased concentration of the iodine labelled compound at the tumor. The targeted tumor is then irradiated with a beam of neutrons having an energy distribution effective for neutron capture. Destruction of the tumor occurs due to high LET particle irradiation of the tissue secondary to the incident neutrons being captured by the boron-10 nuclei. Iodinated sulfidohydroboranes are disclosed which are especially suitable for the method of the invention. In a preferred embodiment, a compound having the formula Na.sub.4 B.sub.12 I.sub.11 SSB.sub.12 I.sub.11, or another pharmaceutically acceptable salt of the compound, may be administered to a cancer patient for boron neutron capture therapy.

  16. Halogenated sulfidohydroboranes for nuclear medicine and boron neutron capture therapy

    DOEpatents

    Miura, Michiko; Slatkin, Daniel N.

    1997-08-05

    A method for performing boron neutron capture therapy for the treatment of tumors is disclosed. The method includes administering to a patient an iodinated sulfidohydroborane, a boron-10-containing compound. The site of the tumor is localized. by visualizing the increased concentration of the iodine labelled compound at the tumor. The targeted tumor is then irradiated with a beam of neutrons having an energy distribution effective for neutron capture. Destruction of the tumor occurs due to high LET particle irradiation of the tissue secondary to the incident neutrons being captured by the boron-10 nuclei. Iodinated sulfidohydroboranes are disclosed which are especially suitable for the method of the invention. In a preferred embodiment, a compound having the formula Na.sub.4 B.sub.12 I.sub.11 SSB.sub.12 I.sub.11, or another pharmaceutically acceptable salt of the compound, may be administered to a cancer patient for boron neutron capture therapy.

  17. Halogenated sulfidohydroboranes for nuclear medicine and boron neutron capture therapy

    DOEpatents

    Miura, M.; Slatkin, D.N.

    1995-10-03

    A method for performing boron neutron capture therapy for the treatment of tumors is disclosed. The method includes administering to a patient an iodinated sulfidohydroborane, a boron-10-containing compound. The site of the tumor is localized by visualizing the increased concentration of the iodine labelled compound at the tumor. The targeted tumor is then irradiated with a beam of neutrons having an energy distribution effective for neutron capture. Destruction of the tumor occurs due to high LET particle irradiation of the tissue secondary to the incident neutrons being captured by the boron-10 nuclei. Iodinated sulfidohydroboranes are disclosed which are especially suitable for the method of the invention. In a preferred embodiment, a compound having the formula Na{sub 4}B{sub 12}I{sub 11}SSB{sub 12}I{sub 11}, or another pharmaceutically acceptable salt of the compound, may be administered to a cancer patient for boron neutron capture therapy. 1 fig.

  18. Halogenated sulfidohydroboranes for nuclear medicine and boron neutron capture therapy

    DOEpatents

    Miura, M.; Slatkin, D.N.

    1997-03-18

    A method for performing boron neutron capture therapy for the treatment of tumors is disclosed. The method includes administering to a patient an iodinated sulfidohydroborane, a boron-10-containing compound. The site of the tumor is localized by visualizing the increased concentration of the iodine labelled compound at the tumor. The targeted tumor is then irradiated with a beam of neutrons having an energy distribution effective for neutron capture. Destruction of the tumor occurs due to high LET particle irradiation of the tissue secondary to the incident neutrons being captured by the boron-10 nuclei. Iodinated sulfidohydroboranes are disclosed which are especially suitable for the method of the invention. In a preferred embodiment, a compound having the formula Na{sub 4}B{sub 12}I{sub 11}SSB{sub 12}I{sub 11}, or another pharmaceutically acceptable salt of the compound, may be administered to a cancer patient for boron neutron capture therapy. 1 fig.

  19. Halogenated sulfidohydroboranes for nuclear medicine and boron neutron capture therapy

    DOEpatents

    Miura, M.; Slatkin, D.N.

    1997-08-05

    A method for performing boron neutron capture therapy for the treatment of tumors is disclosed. The method includes administering to a patient an iodinated sulfidohydroborane, a boron-10-containing compound. The site of the tumor is localized by visualizing the increased concentration of the iodine labelled compound at the tumor. The targeted tumor is then irradiated with a beam of neutrons having an energy distribution effective for neutron capture. Destruction of the tumor occurs due to high LET particle irradiation of the tissue secondary to the incident neutrons being captured by the boron-10 nuclei. Iodinated sulfidohydroboranes are disclosed which are especially suitable for the method of the invention. In a preferred embodiment, a compound having the formula Na{sub 4}B{sub 12}I{sub 11}SSB{sub 12}I{sub 11}, or another pharmaceutically acceptable salt of the compound, may be administered to a cancer patient for boron neutron capture therapy. 1 fig.

  20. Monte Carlo calculations of thermal neutron capture in gadolinium: a comparison of GEANT4 and MCNP with measurements.

    PubMed

    Enger, Shirin A; Munck af Rosenschöld, Per; Rezaei, Arash; Lundqvist, Hans

    2006-02-01

    GEANT4 is a Monte Carlo code originally implemented for high-energy physics applications and is well known for particle transport at high energies. The capacity of GEANT4 to simulate neutron transport in the thermal energy region is not equally well known. The aim of this article is to compare MCNP, a code commonly used in low energy neutron transport calculations and GEANT4 with experimental results and select the suitable code for gadolinium neutron capture applications. To account for the thermal neutron scattering from chemically bound atoms [S(alpha,beta)] in biological materials a comparison of thermal neutron fluence in tissue-like poly(methylmethacrylate) phantom is made with MCNP4B, GEANT4 6.0 patch1, and measurements from the neutron capture therapy (NCT) facility at the Studsvik, Sweden. The fluence measurements agreed with MCNP calculated results considering S(alpha,beta). The location of the thermal neutron peak calculated with MCNP without S(alpha,beta) and GEANT4 is shifted by about 0.5 cm towards a shallower depth and is 25%-30% lower in amplitude. Dose distribution from the gadolinium neutron capture reaction is then simulated by MCNP and compared with measured data. The simulations made by MCNP agree well with experimental results. As long as thermal neutron scattering from chemically bound atoms are not included in GEANT4 it is not suitable for NCT applications.

  1. Biomedical applications of nanodiamonds in imaging and therapy.

    PubMed

    Perevedentseva, Elena; Lin, Yu-Chung; Jani, Mona; Cheng, Chia-Liang

    2013-12-01

    Nanodiamonds have attracted remarkable scientific attention for bioimaging and therapeutic applications owing to their low toxicity with many cell lines, convenient surface properties and stable fluorescence without photobleaching. Newer techniques are being applied to enhance fluorescence. Interest is also growing in exploring the possibilities for modifying the nanodiamond surface and functionalities by attaching various biomolecules of interest for interaction with the targets. The potential of Raman spectroscopy and fluorescence properties of nanodiamonds has been explored for bioimaging and drug delivery tracing. The interest in nanodiamonds' biological/medical application appears to be continuing with enhanced focus. In this review an attempt is made to capture the scope, spirit and recent developments in the field of nanodiamonds for biomedical applications.

  2. Posterior Wall Capture and Femoral Artery Stenosis Following Use of StarClose Closing Device: Diagnosis and Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stefanczyk, Ludomir; Elgalal, Marcin T., E-mail: telgalal@yahoo.co.uk; Szubert, Wojciech

    2013-10-15

    A case of femoral artery obstruction following application of a StarClose type arterial puncture closing device (APCD) is presented. Ultrasonographic and angiographic imaging of this complication was obtained. The posterior wall of the vessel was accidentally caught in the anchoring element of the nitinol clip. This complication was successfully resolved by endovascular treatment and the implantation of a stent.

  3. Deep magnetic capture of magnetically loaded cells for spatially targeted therapeutics.

    PubMed

    Huang, Zheyong; Pei, Ning; Wang, Yanyan; Xie, Xinxing; Sun, Aijun; Shen, Li; Zhang, Shuning; Liu, Xuebo; Zou, Yunzeng; Qian, Juying; Ge, Junbo

    2010-03-01

    Magnetic targeting has recently demonstrated potential in promoting magnetically loaded cell delivery to target lesion, but its application is limited by magnetic attenuation. For deep magnetic capture of cells for spatial targeting therapeutics, we designed a magnetic pole, in which the magnetic field density can be focused at a distance from the pole. As flowing through a tube served as a model of blood vessels, the magnetically loaded mesenchymal stem cells (MagMSCs) were highly enriched at the site distance from the magnetic pole. The cell capture efficiency was positively influenced by the magnetic flux density, and inversely influenced by the flow velocity, and well-fitted with the deductive value by theoretical considerations. It appeared to us that the spatially-focused property of the magnetic apparatus promises a new deep targeting strategy to promote homing and engraftment for cellular therapy. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  4. In vivo evaluation of neutron capture therapy effectivity using calcium phosphate-based nanoparticles as Gd-DTPA delivery agent.

    PubMed

    Dewi, Novriana; Mi, Peng; Yanagie, Hironobu; Sakurai, Yuriko; Morishita, Yasuyuki; Yanagawa, Masashi; Nakagawa, Takayuki; Shinohara, Atsuko; Matsukawa, Takehisa; Yokoyama, Kazuhito; Cabral, Horacio; Suzuki, Minoru; Sakurai, Yoshinori; Tanaka, Hiroki; Ono, Koji; Nishiyama, Nobuhiro; Kataoka, Kazunori; Takahashi, Hiroyuki

    2016-04-01

    A more immediate impact for therapeutic approaches of current clinical research efforts is of major interest, which might be obtained by developing a noninvasive radiation dose-escalation strategy, and neutron capture therapy represents one such novel approach. Furthermore, some recent researches on neutron capture therapy have focused on using gadolinium as an alternative or complementary for currently used boron, taking into account several advantages that gadolinium offers. Therefore, in this study, we carried out feasibility evaluation for both single and multiple injections of gadolinium-based MRI contrast agent incorporated in calcium phosphate nanoparticles as neutron capture therapy agent. In vivo evaluation was performed on colon carcinoma Col-26 tumor-bearing mice irradiated at nuclear reactor facility of Kyoto University Research Reactor Institute with average neutron fluence of 1.8 × 10(12) n/cm(2). Antitumor effectivity was evaluated based on tumor growth suppression assessed until 27 days after neutron irradiation, followed by histopathological analysis on tumor slice. The experimental results showed that the tumor growth of irradiated mice injected beforehand with Gd-DTPA-incorporating calcium phosphate-based nanoparticles was suppressed up to four times higher compared to the non-treated group, supported by the results of histopathological analysis. The results of antitumor effectivity observed on tumor-bearing mice after neutron irradiation indicated possible effectivity of gadolinium-based neutron capture therapy treatment.

  5. Monte Carlo based dosimetry for neutron capture therapy of brain tumors

    NASA Astrophysics Data System (ADS)

    Zaidi, Lilia; Belgaid, Mohamed; Khelifi, Rachid

    2016-11-01

    Boron Neutron Capture Therapy (BNCT) is a biologically targeted, radiation therapy for cancer which combines neutron irradiation with a tumor targeting agent labeled with a boron10 having a high thermal neutron capture cross section. The tumor area is subjected to the neutron irradiation. After a thermal neutron capture, the excited 11B nucleus fissions into an alpha particle and lithium recoil nucleus. The high Linear Energy Transfer (LET) emitted particles deposit their energy in a range of about 10μm, which is of the same order of cell diameter [1], at the same time other reactions due to neutron activation with body component are produced. In-phantom measurement of physical dose distribution is very important for BNCT planning validation. Determination of total absorbed dose requires complex calculations which were carried out using the Monte Carlo MCNP code [2].

  6. Dynamic Geometry Capture with a Multi-View Structured-Light System

    DTIC Science & Technology

    2014-12-19

    funding was never a problem during my studies . One of the best parts of my time at UC Berkeley has been working with colleagues within the Video and...scientific and medical applications such as quantifying improvement in physical therapy and measuring unnatural poses in ergonomic studies . Specifically... cases with limited scene texture. This direct generation of surface geometry provides us with a distinct advantage over multi-camera based systems. For

  7. Capture and Genetic Analysis of Circulating Tumor Cells Using a Magnetic Separation Device (Magnetic Sifter).

    PubMed

    Ooi, Chin Chun; Park, Seung-Min; Wong, Dawson J; Gambhir, Sanjiv S; Wang, Shan X

    2017-01-01

    Circulating tumor cells (CTCs) are currently widely studied for their potential application as part of a liquid biopsy. These cells are shed from the primary tumor into the circulation, and are postulated to provide insight into the molecular makeup of the actual tumor in a minimally invasive manner. However, they are extremely rare in blood, with typical concentrations of 1-100 in a milliliter of blood; hence, a need exists for a rapid and high-purity method for isolating CTCs from whole blood. Here, we describe the application of a microfabricated magnetic sifter toward isolation of CTCs from whole blood at volumetric flow rates of 10 mL/h, along with the use of a PDMS-based nanowell system for single-cell gene expression profiling. This method allows rapid isolation of CTCs and subsequent integration with downstream genetic profiling methods for clinical applications such as targeted therapy, therapy monitoring, or further biological studies.

  8. Porphyrins for boron neutron capture therapy

    DOEpatents

    Miura, Michiko; Gabel, Detlef

    1990-01-01

    Novel compounds for treatment of brain tumors in Boron Neutron Capture Therapy are disclosed. A method for preparing the compounds as well as pharmaceutical compositions containing said compounds are also disclosed. The compounds are water soluble, non-toxic and non-labile boronated porphyrins which show significant uptake and retention in tumors.

  9. Monte Carlo treatment planning for molecular targeted radiotherapy within the MINERVA system

    NASA Astrophysics Data System (ADS)

    Lehmann, Joerg; Hartmann Siantar, Christine; Wessol, Daniel E.; Wemple, Charles A.; Nigg, David; Cogliati, Josh; Daly, Tom; Descalle, Marie-Anne; Flickinger, Terry; Pletcher, David; DeNardo, Gerald

    2005-03-01

    The aim of this project is to extend accurate and patient-specific treatment planning to new treatment modalities, such as molecular targeted radiation therapy, incorporating previously crafted and proven Monte Carlo and deterministic computation methods. A flexible software environment is being created that allows planning radiation treatment for these new modalities and combining different forms of radiation treatment with consideration of biological effects. The system uses common input interfaces, medical image sets for definition of patient geometry and dose reporting protocols. Previously, the Idaho National Engineering and Environmental Laboratory (INEEL), Montana State University (MSU) and Lawrence Livermore National Laboratory (LLNL) had accrued experience in the development and application of Monte Carlo based, three-dimensional, computational dosimetry and treatment planning tools for radiotherapy in several specialized areas. In particular, INEEL and MSU have developed computational dosimetry systems for neutron radiotherapy and neutron capture therapy, while LLNL has developed the PEREGRINE computational system for external beam photon-electron therapy. Building on that experience, the INEEL and MSU are developing the MINERVA (modality inclusive environment for radiotherapeutic variable analysis) software system as a general framework for computational dosimetry and treatment planning for a variety of emerging forms of radiotherapy. In collaboration with this development, LLNL has extended its PEREGRINE code to accommodate internal sources for molecular targeted radiotherapy (MTR), and has interfaced it with the plugin architecture of MINERVA. Results from the extended PEREGRINE code have been compared to published data from other codes, and found to be in general agreement (EGS4—2%, MCNP—10%) (Descalle et al 2003 Cancer Biother. Radiopharm. 18 71-9). The code is currently being benchmarked against experimental data. The interpatient variability of the drug pharmacokinetics in MTR can only be properly accounted for by image-based, patient-specific treatment planning, as has been common in external beam radiation therapy for many years. MINERVA offers 3D Monte Carlo-based MTR treatment planning as its first integrated operational capability. The new MINERVA system will ultimately incorporate capabilities for a comprehensive list of radiation therapies. In progress are modules for external beam photon-electron therapy and boron neutron capture therapy (BNCT). Brachytherapy and proton therapy are planned. Through the open application programming interface (API), other groups can add their own modules and share them with the community.

  10. Development of a new multi-modal Monte-Carlo radiotherapy planning system.

    PubMed

    Kumada, H; Nakamura, T; Komeda, M; Matsumura, A

    2009-07-01

    A new multi-modal Monte-Carlo radiotherapy planning system (developing code: JCDS-FX) is under development at Japan Atomic Energy Agency. This system builds on fundamental technologies of JCDS applied to actual boron neutron capture therapy (BNCT) trials in JRR-4. One of features of the JCDS-FX is that PHITS has been applied to particle transport calculation. PHITS is a multi-purpose particle Monte-Carlo transport code. Hence application of PHITS enables to evaluate total doses given to a patient by a combined modality therapy. Moreover, JCDS-FX with PHITS can be used for the study of accelerator based BNCT. To verify calculation accuracy of the JCDS-FX, dose evaluations for neutron irradiation of a cylindrical water phantom and for an actual clinical trial were performed, then the results were compared with calculations by JCDS with MCNP. The verification results demonstrated that JCDS-FX is applicable to BNCT treatment planning in practical use.

  11. Proposed Standardized Neurological Endpoints for Cardiovascular Clinical Trials: An Academic Research Consortium Initiative.

    PubMed

    Lansky, Alexandra J; Messé, Steven R; Brickman, Adam M; Dwyer, Michael; Bart van der Worp, H; Lazar, Ronald M; Pietras, Cody G; Abrams, Kevin J; McFadden, Eugene; Petersen, Nils H; Browndyke, Jeffrey; Prendergast, Bernard; Ng, Vivian G; Cutlip, Donald E; Kapadia, Samir; Krucoff, Mitchell W; Linke, Axel; Scala Moy, Claudia; Schofer, Joachim; van Es, Gerrit-Anne; Virmani, Renu; Popma, Jeffrey; Parides, Michael K; Kodali, Susheel; Bilello, Michel; Zivadinov, Robert; Akar, Joseph; Furie, Karen L; Gress, Daryl; Voros, Szilard; Moses, Jeffrey; Greer, David; Forrest, John K; Holmes, David; Kappetein, Arie P; Mack, Michael; Baumbach, Andreas

    2018-05-14

    Surgical and catheter-based cardiovascular procedures and adjunctive pharmacology have an inherent risk of neurological complications. The current diversity of neurological endpoint definitions and ascertainment methods in clinical trials has led to uncertainties in the neurological risk attributable to cardiovascular procedures and inconsistent evaluation of therapies intended to prevent or mitigate neurological injury. Benefit-risk assessment of such procedures should be on the basis of an evaluation of well-defined neurological outcomes that are ascertained with consistent methods and capture the full spectrum of neurovascular injury and its clinical effect. The Neurologic Academic Research Consortium is an international collaboration intended to establish consensus on the definition, classification, and assessment of neurological endpoints applicable to clinical trials of a broad range of cardiovascular interventions. Systematic application of the proposed definitions and assessments will improve our ability to evaluate the risks of cardiovascular procedures and the safety and effectiveness of preventive therapies.

  12. Accelerator driven neutron source design via beryllium target and 208Pb moderator for boron neutron capture therapy in alternative treatment strategy by Monte Carlo method.

    PubMed

    Khorshidi, Abdollah

    2017-01-01

    The reactor has increased its area of application into medicine especially boron neutron capture therapy (BNCT); however, accelerator-driven neutron sources can be used for therapy purposes. The present study aimed to discuss an alternative method in BNCT functions by a small cyclotron with low current protons based on Karaj cyclotron in Iran. An epithermal neutron spectrum generator was simulated with 30 MeV proton energy for BNCT purposes. A low current of 300 μA of the proton beam in spallation target concept via 9Be target was accomplished to model neutron spectrum using 208Pb moderator around the target. The graphite reflector and dual layer collimator were planned to prevent and collimate the neutrons produced from proton interactions. Neutron yield per proton, energy distribution, flux, and dose components in the simulated head phantom were estimated by MCNPX code. The neutron beam quality was investigated by diverse filters thicknesses. The maximum epithermal flux transpired using Fluental, Fe, Li, and Bi filters with thicknesses of 7.4, 3, 0.5, and 4 cm, respectively; as well as the epithermal to thermal neutron flux ratio was 161. Results demonstrated that the induced neutrons from a low energy and low current proton may be effective in tumor therapy using 208Pb moderator with average lethargy and also graphite reflector with low absorption cross section to keep the generated neutrons. Combination of spallation-based BNCT and proton therapy can be especially effective, if a high beam intensity cyclotron becomes available.

  13. Graft Immunocomplex Capture Fluorescence Analysis to Detect Donor-Specific Antibodies and HLA Antigen Complexes in the Allograft.

    PubMed

    Nakamura, Tsukasa; Ushigome, Hidetaka; Watabe, Kiyoko; Imanishi, Yui; Masuda, Koji; Matsuyama, Takehisa; Harada, Shumpei; Koshino, Katsuhiro; Iida, Taku; Nobori, Shuji; Yoshimura, Norio

    2017-04-01

    Immunocomplex capture fluorescence analysis (ICFA) is an attractive method to detect donor-specific anti-HLA antibodies (DSA) and HLA antigen complexes. Currently, antibody-mediated rejection (AMR) due to DSA is usually diagnosed by C4d deposition and serological DSA detection. Conversely, there is a discrepancy between these findings frequently. Thereupon, our graft ICFA technique may contribute to establish the diagnosis of AMR. Graft samples were obtained by a percutaneous needle biopsy. Then, the specimen was dissolved in PBS by the lysis buffer. Subsequently, HLA antigens were captured by anti-HLA beads. Then, DSA-HLA complexes were detected by PE-conjugated anti-human IgG antibodies, where DSA had already reacted with the allograft in vivo, analyzed by a Luminex system. A ratio (sample MFI/blank beads MFI) was calculated: ≥ 1.0 was determined as positive. We found that DSA-HLA complexes in the graft were successfully detected from only slight positive 1.03 to 79.27 in a chronic active AMR patient by graft ICFA. Next, positive graft ICFA had predicted the early phase of AMR (MFI ratio: 1.38) even in patients with no serum DSA. Finally, appropriate therapies for AMR deleted DSA deposition (MFI ratio from 0.3 to 0.7) from allografts. This novel application would detect early phase or incomplete pathological cases of AMR, which could lead to a correct diagnosis and initiation of appropriate therapies. Moreover, graft ICFA might address a variety of long-standing questions in terms of DSA. AMR: Antibody-mediated rejection; DSA: Donor-specific antibodies; ICFA: Immunocomplex capture fluorescence analysis.

  14. Boron neutron capture therapy for oral precancer: proof of principle in an experimental animal model.

    PubMed

    Monti Hughes, A M; Pozzi, E C C; Thorp, S; Garabalino, M A; Farías, R O; González, S J; Heber, E M; Itoiz, M E; Aromando, R F; Molinari, A J; Miller, M; Nigg, D W; Curotto, P; Trivillin, V A; Schwint, A E

    2013-11-01

    Field-cancerized tissue can give rise to second primary tumours, causing therapeutic failure. Boron neutron capture therapy (BNCT) is based on biological targeting and would serve to treat undetectable foci of malignant transformation. The aim of this study was to optimize BNCT for the integral treatment for oral cancer, with particular emphasis on the inhibitory effect on tumour development originating in precancerous conditions, and radiotoxicity of different BNCT protocols in a hamster cheek pouch oral precancer model. Groups of cancerized hamsters were locally exposed to single or double (2 or 4 weeks apart) applications of BNCT at different dose levels, mediated by the boron compounds boronophenylalanine (BPA) or BPA and decahydrodecaborate (GB-10) administered jointly. Cancerized, sham-irradiated hamsters served as controls. Clinical status, tumour development from field-cancerized tissue and mucositis were followed for 8 months. A double application (4 weeks apart) of BNCT mediated by GB-10+ BPA at a total dose of 10 Gy in two 5-Gy doses rendered the best therapeutic advantage (63-100% inhibition of tumour development from field-cancerized tissue), minimizing dose-limiting mucositis. BNCT can be optimized for the integral treatment for head and neck cancer, considering the implications for field-cancerized tissue. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. An Assessment of the Potential Use of BNNTs for Boron Neutron Capture Therapy.

    PubMed

    Ferreira, Tiago H; Miranda, Marcelo C; Rocha, Zildete; Leal, Alexandre S; Gomes, Dawidson A; Sousa, Edesia M B

    2017-04-12

    Currently, nanostructured compounds have been standing out for their optical, mechanical, and chemical features and for the possibilities of manipulation and regulation of complex biological processes. One of these compounds is boron nitride nanotubes (BNNTs), which are a nanostructured material analog to carbon nanotubes, but formed of nitrogen and boron atoms. BNNTs present high thermal stability along with high chemical inertia. Among biological applications, its biocompatibility, cellular uptake, and functionalization potential can be highlighted, in addition to its eased utilization due to its nanometric size and tumor cell internalization. When it comes to new forms of therapy, we can draw attention to boron neutron capture therapy (BNCT), an experimental radiotherapy characterized by a boron-10 isotope carrier inside the target and a thermal neutron beam focused on it. The activation of the boron-10 atom by a neutron generates a lithium atom, a gamma ray, and an alpha particle, which can be used to destroy tumor tissues. The aim of this work was to use BNNTs as a boron-10 carrier for BNCT and to demonstrate its potential. The nanomaterial was characterized through XRD, FTIR, and SEM. The WST-8 assay was performed to confirm the cell viability of BNNTs. The cells treated with BNNTs were irradiated with the neutron beam of a Triga reactor, and the apoptosis caused by the activation of the BNNTs was measured with a calcein AM/propidium iodide test. The results demonstrate that this nanomaterial is a promising candidate for cancer therapy through BNCT.

  16. Pharmaco-thermodynamics of deuterium-induced oedema in living rat brain via 1H2O MRI: implications for boron neutron capture therapy of malignant brain tumours

    NASA Astrophysics Data System (ADS)

    Medina, Daniel C.; Li, Xin; Springer, Charles S., Jr.

    2005-05-01

    In addition to its common usage as a tracer in metabolic and physiological studies, deuterium possesses anti-tumoural activity and confers protection against γ-irradiation. A more recent interest in deuterium emanates from the search for alternatives capable of improving neutron penetrance whilst reducing healthy tissue radiation dose deposition in boron neutron capture therapy of malignant brain tumours. Despite this potential clinical application, deuterium induces brain oedema, which is detrimental to neutron capture therapy. In this study, five adult male rats were titrated with deuterated drinking water while brain oedema was monitored via water proton magnetic resonance imaging. This report concludes that deuterium, as well as deuterium-induced brain oedema, possesses a uniform brain bio-distribution. At a steady-state blood fluid deuteration value of 16%, when the deuterium isotope fraction in drinking water was 25%, a mean oedematous volume change of 9 ± 2% (p-value <0.001) was observed in the rat brain—this may account for neurological and behavioural abnormalities found in mammals drinking highly deuterated water. In addition to characterizing the pharmaco-thermodynamics of deuterium-induced oedema, this report also estimates the impact of oedema on thermal neutron enhancement and effective dose reduction factors using simple linear transport calculations. While body fluid deuteration enhances thermal neutron flux penetrance and reduces dose deposition, oedema has the opposite effect because it increases the volume of interest, e.g., the brain volume. Thermal neutron enhancement and effective dose reduction factors could be reduced by as much as ~10% in the presence of a 9% water volume increase (oedema). All three authors have contributed equally to this work.

  17. Optical Method to Quantify Mechanical Contraction and Calcium Transients of Human Pluripotent Stem Cell-Derived Cardiomyocytes.

    PubMed

    Hansen, Katrina J; Favreau, John T; Gershlak, Joshua R; Laflamme, Michael A; Albrecht, Dirk R; Gaudette, Glenn R

    2017-08-01

    Differentiation of human pluripotent stem cells into cardiomyocytes (hPS-CMs) holds promise for myocardial regeneration therapies, drug discovery, and models of cardiac disease. Potential cardiotoxicities may affect hPS-CM mechanical contraction independent of calcium signaling. Herein, a method using an image capture system is described to measure hPS-CM contractility and intracellular calcium concurrently, with high spatial and temporal resolution. The image capture system rapidly alternates between brightfield and epifluorescent illumination of contracting cells. Mechanical contraction is quantified by a speckle tracking algorithm applied to brightfield image pairs, whereas calcium transients are measured by a fluorescent calcium reporter. This technique captured changes in contractile strain, calcium transients, and beat frequency of hPS-CMs over 21 days in culture, as well as acute responses to isoproterenol and Cytochalasin D. The technique described above can be applied without the need to alter the culture platform, allowing for determination of hPS-CM behavior over weeks in culture for drug discovery and myocardial regeneration applications.

  18. Construction of an Aptamer-SiRNA Chimera-Modified Tissue-Engineered Blood Vessel for Cell-Type-Specific Capture and Delivery.

    PubMed

    Chen, Wen; Zeng, Wen; Sun, Jiansen; Yang, Mingcan; Li, Li; Zhou, Jingting; Wu, Yangxiao; Sun, Jun; Liu, Ge; Tang, Rui; Tan, Ju; Zhu, Chuhong

    2015-06-23

    The application of tissue-engineered blood vessels (TEBVs) is the main developmental direction of vascular replacement therapy. Due to few and/or dysfunctional endothelial progenitor cells (EPCs), it is difficult to successfully construct EPC capture TEBVs in diabetes. RNA has a potential application in cell protection and diabetes treatment, but poor specificity and low efficiency of RNA transfection in vivo limit the application of RNA. On the basis of an acellular vascular matrix, we propose an aptamer-siRNA chimera-modified TEBV that can maintain a satisfactory patency in diabetes. This TEBV consists of two parts, CD133-adenosine kinase (ADK) chimeras and a TEBV scaffold. Our results showed that CD133-ADK chimeras could selectively capture the CD133-positive cells in vivo, and then captured cells can internalize the bound chimeras to achieve RNA self-transfection. Subsequently, CD133-ADK chimeras were cut into ADK siRNA by a dicer, resulting in depletion of ADK. An ADK-deficient cell may act as a bioreactor that sustainably releases adenosine. To reduce nonspecific RNA transfection, we increased the proportion of HAuCl4 during the material preparation, through which the transfection capacity of polyethylenimine (PEI)/polyethylene glycol (PEG)-capped gold nanoparticles (PEI/PEG-AuNPs) was significantly decreased and the ability of TEBV to resist tensile and liquid shear stress was greatly enhanced. PEG and 2'-O-methyl modification was used to enhance the in vivo stability of RNA chimeras. At day 30 postgrafting, the patency rate of CD133-ADK chimera-modified TEBVs reached 90% in diabetic rats and good endothelialization was observed.

  19. Proceedings of the first international symposium on neutron capture therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fairchild, R.G.; Brownell, G.L.

    This meeting was arranged jointly by MIT and BNL in order to illuminate progress in the synthesis and targeting of boron compounds and to evaluate and document progress in radiobiological and dosimetric aspects of neutron capture therapy. It is hoped that this meeting will facilitate transfer of information between groups working in these fields, and encourage synergistic collaboration.

  20. Development of a multi-modal Monte-Carlo radiation treatment planning system combined with PHITS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumada, Hiroaki; Nakamura, Takemi; Komeda, Masao

    A new multi-modal Monte-Carlo radiation treatment planning system is under development at Japan Atomic Energy Agency. This system (developing code: JCDS-FX) builds on fundamental technologies of JCDS. JCDS was developed by JAEA to perform treatment planning of boron neutron capture therapy (BNCT) which is being conducted at JRR-4 in JAEA. JCDS has many advantages based on practical accomplishments for actual clinical trials of BNCT at JRR-4, the advantages have been taken over to JCDS-FX. One of the features of JCDS-FX is that PHITS has been applied to particle transport calculation. PHITS is a multipurpose particle Monte-Carlo transport code, thus applicationmore » of PHITS enables to evaluate doses for not only BNCT but also several radiotherapies like proton therapy. To verify calculation accuracy of JCDS-FX with PHITS for BNCT, treatment planning of an actual BNCT conducted at JRR-4 was performed retrospectively. The verification results demonstrated the new system was applicable to BNCT clinical trials in practical use. In framework of R and D for laser-driven proton therapy, we begin study for application of JCDS-FX combined with PHITS to proton therapy in addition to BNCT. Several features and performances of the new multimodal Monte-Carlo radiotherapy planning system are presented.« less

  1. Optical dosimetry of radiotherapy beams using Cherenkov radiation: the relationship between light emission and dose.

    PubMed

    Glaser, Adam K; Zhang, Rongxiao; Gladstone, David J; Pogue, Brian W

    2014-07-21

    Recent studies have proposed that light emitted by the Cherenkov effect may be used for a number of radiation therapy dosimetry applications. There is a correlation between the captured light and expected dose under certain conditions, yet discrepancies have also been observed and a complete examination of the theoretical differences has not been done. In this study, a fundamental comparison between the Cherenkov emission and absorbed dose was explored for x-ray photons, electrons, and protons using both a theoretical and Monte Carlo-based analysis. Based on the findings of where dose correlates with Cherenkov emission, it was concluded that for x-ray photons the light emission would be optimally suited for narrow beam stereotactic radiation therapy and surgery validation studies, for verification of dynamic intensity-modulated and volumetric modulated arc therapy treatment plans in water tanks, near monoenergetic sources (e.g., Co-60 and brachy therapy sources) and also for entrance and exit surface imaging dosimetry of both narrow and broad beams. For electron use, Cherenkov emission was found to be only suitable for surface dosimetry applications. Finally, for proton dosimetry, there exists a fundamental lack of Cherenkov emission at the Bragg peak, making the technique of little use, although post-irradiation detection of light emission from radioisotopes could prove to be useful.

  2. Histamine reduces boron neutron capture therapy-induced mucositis in an oral precancer model.

    PubMed

    Monti Hughes, A; Pozzi, Ecc; Thorp, S I; Curotto, P; Medina, V A; Martinel Lamas, D J; Rivera, E S; Garabalino, M A; Farías, R O; Gonzalez, S J; Heber, E M; Itoiz, M E; Aromando, R F; Nigg, D W; Trivillin, V A; Schwint, A E

    2015-09-01

    Searching for more effective and selective therapies for head and neck cancer, we demonstrated the therapeutic effect of boron neutron capture therapy (BNCT) to treat oral cancer and inhibit long-term tumor development from field-cancerized tissue in the hamster cheek pouch model. However, BNCT-induced mucositis in field-cancerized tissue was dose limiting. In a clinical scenario, oral mucositis affects patients' treatment and quality of life. Our aim was to evaluate different radioprotectors, seeking to reduce the incidence of BNCT-induced severe mucositis in field-cancerized tissue. Cancerized pouches treated with BNCT mediated by boronophenylalanine at 5 Gy were treated as follows: control: saline solution; Hishigh : histamine 5 mg kg(-1) ; Hislow : histamine 1 mg kg(-1) ; and JNJ7777120: 10 mg kg(-1). Hislow reduced the incidence of severe mucositis in field-cancerized tissue to 17% vs 55%; Hishigh : 67%; JNJ7777120: 57%. Hislow was non-toxic and did not compromise the long-term therapeutic effect of BNCT or alter gross boron concentration. Histamine reduces BNCT-induced mucositis in experimental oral precancer without jeopardizing therapeutic efficacy. The fact that both histamine and boronophenylalanine are approved for use in humans bridges the gap between experimental work and potential clinical application to reduce BNCT-induced radiotoxicity in patients with head and neck cancer. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. “Sequential” Boron Neutron Capture Therapy (BNCT): A Novel Approach to BNCT for the Treatment of Oral Cancer in the Hamster Cheek Pouch Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ana J. Molinari; Emiliano C. C. Pozzi; Andrea Monti Hughes

    In the present study we evaluated the therapeutic effect and/or potential radiotoxicity of the novel “Tandem” Boron Neutron Capture Therapy (T-BNCT) for the treatment of oral cancer in the hamster cheek pouch model at RA-3 Nuclear Reactor. Two groups of animals were treated with “Tandem BNCT”, i.e. BNCT mediated by boronophenylalanine (BPA) followed by BNCT mediated by sodium decahydrodecaborate (GB-10) either 24 h (T-24h-BNCT) or 48 h (T-48h-BNCT) later. A total tumor dose-matched single application of BNCT mediated by BPA and GB-10 administered jointly [(BPA + GB-10)-BNCT] was administered to an additional group of animals. At 28 days post-treatment, T-24h-BNCTmore » and T-48h-BNCT induced, respectively, overall tumor control (OTC) of 95% and 91%, with no statistically significant differences between protocols. Tumor response for the single application of (BPA + GB-10)-BNCT was 75%, significantly lower than for T-BNCT. The T-BNCT protocols and (BPA + GB-10)-BNCT induced reversible mucositis in dose-limiting precancerous tissue around treated tumors, reaching Grade 3/4 mucositis in 47% and 60% of the animals respectively. No normal tissue radiotoxicity was associated to tumor control for any of the protocols. “Tandem” BNCT enhances tumor control in oral cancer and reduces or, at worst, does not increase, mucositis in dose-limiting precancerous tissue.« less

  4. Microdosimetric Modeling of Biological Effectiveness for Boron Neutron Capture Therapy Considering Intra- and Intercellular Heterogeneity in 10B Distribution.

    PubMed

    Sato, Tatsuhiko; Masunaga, Shin-Ichiro; Kumada, Hiroaki; Hamada, Nobuyuki

    2018-01-17

    We here propose a new model for estimating the biological effectiveness for boron neutron capture therapy (BNCT) considering intra- and intercellular heterogeneity in 10 B distribution. The new model was developed from our previously established stochastic microdosimetric kinetic model that determines the surviving fraction of cells irradiated with any radiations. In the model, the probability density of the absorbed doses in microscopic scales is the fundamental physical index for characterizing the radiation fields. A new computational method was established to determine the probability density for application to BNCT using the Particle and Heavy Ion Transport code System PHITS. The parameters used in the model were determined from the measured surviving fraction of tumor cells administrated with two kinds of 10 B compounds. The model quantitatively highlighted the indispensable need to consider the synergetic effect and the dose dependence of the biological effectiveness in the estimate of the therapeutic effect of BNCT. The model can predict the biological effectiveness of newly developed 10 B compounds based on their intra- and intercellular distributions, and thus, it can play important roles not only in treatment planning but also in drug discovery research for future BNCT.

  5. Proposed Standardized Neurological Endpoints for Cardiovascular Clinical Trials: An Academic Research Consortium Initiative.

    PubMed

    Lansky, Alexandra J; Messé, Steven R; Brickman, Adam M; Dwyer, Michael; van der Worp, H Bart; Lazar, Ronald M; Pietras, Cody G; Abrams, Kevin J; McFadden, Eugene; Petersen, Nils H; Browndyke, Jeffrey; Prendergast, Bernard; Ng, Vivian G; Cutlip, Donald E; Kapadia, Samir; Krucoff, Mitchell W; Linke, Axel; Moy, Claudia Scala; Schofer, Joachim; van Es, Gerrit-Anne; Virmani, Renu; Popma, Jeffrey; Parides, Michael K; Kodali, Susheel; Bilello, Michel; Zivadinov, Robert; Akar, Joseph; Furie, Karen L; Gress, Daryl; Voros, Szilard; Moses, Jeffrey; Greer, David; Forrest, John K; Holmes, David; Kappetein, Arie P; Mack, Michael; Baumbach, Andreas

    2017-02-14

    Surgical and catheter-based cardiovascular procedures and adjunctive pharmacology have an inherent risk of neurological complications. The current diversity of neurological endpoint definitions and ascertainment methods in clinical trials has led to uncertainties in the neurological risk attributable to cardiovascular procedures and inconsistent evaluation of therapies intended to prevent or mitigate neurological injury. Benefit-risk assessment of such procedures should be on the basis of an evaluation of well-defined neurological outcomes that are ascertained with consistent methods and capture the full spectrum of neurovascular injury and its clinical effect. The Neurologic Academic Research Consortium is an international collaboration intended to establish consensus on the definition, classification, and assessment of neurological endpoints applicable to clinical trials of a broad range of cardiovascular interventions. Systematic application of the proposed definitions and assessments will improve our ability to evaluate the risks of cardiovascular procedures and the safety and effectiveness of preventive therapies. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  6. Mathematical Modeling and Evaluation of Human Motions in Physical Therapy Using Mixture Density Neural Networks

    PubMed Central

    Vakanski, A; Ferguson, JM; Lee, S

    2016-01-01

    Objective The objective of the proposed research is to develop a methodology for modeling and evaluation of human motions, which will potentially benefit patients undertaking a physical rehabilitation therapy (e.g., following a stroke or due to other medical conditions). The ultimate aim is to allow patients to perform home-based rehabilitation exercises using a sensory system for capturing the motions, where an algorithm will retrieve the trajectories of a patient’s exercises, will perform data analysis by comparing the performed motions to a reference model of prescribed motions, and will send the analysis results to the patient’s physician with recommendations for improvement. Methods The modeling approach employs an artificial neural network, consisting of layers of recurrent neuron units and layers of neuron units for estimating a mixture density function over the spatio-temporal dependencies within the human motion sequences. Input data are sequences of motions related to a prescribed exercise by a physiotherapist to a patient, and recorded with a motion capture system. An autoencoder subnet is employed for reducing the dimensionality of captured sequences of human motions, complemented with a mixture density subnet for probabilistic modeling of the motion data using a mixture of Gaussian distributions. Results The proposed neural network architecture produced a model for sets of human motions represented with a mixture of Gaussian density functions. The mean log-likelihood of observed sequences was employed as a performance metric in evaluating the consistency of a subject’s performance relative to the reference dataset of motions. A publically available dataset of human motions captured with Microsoft Kinect was used for validation of the proposed method. Conclusion The article presents a novel approach for modeling and evaluation of human motions with a potential application in home-based physical therapy and rehabilitation. The described approach employs the recent progress in the field of machine learning and neural networks in developing a parametric model of human motions, by exploiting the representational power of these algorithms to encode nonlinear input-output dependencies over long temporal horizons. PMID:28111643

  7. Mathematical Modeling and Evaluation of Human Motions in Physical Therapy Using Mixture Density Neural Networks.

    PubMed

    Vakanski, A; Ferguson, J M; Lee, S

    2016-12-01

    The objective of the proposed research is to develop a methodology for modeling and evaluation of human motions, which will potentially benefit patients undertaking a physical rehabilitation therapy (e.g., following a stroke or due to other medical conditions). The ultimate aim is to allow patients to perform home-based rehabilitation exercises using a sensory system for capturing the motions, where an algorithm will retrieve the trajectories of a patient's exercises, will perform data analysis by comparing the performed motions to a reference model of prescribed motions, and will send the analysis results to the patient's physician with recommendations for improvement. The modeling approach employs an artificial neural network, consisting of layers of recurrent neuron units and layers of neuron units for estimating a mixture density function over the spatio-temporal dependencies within the human motion sequences. Input data are sequences of motions related to a prescribed exercise by a physiotherapist to a patient, and recorded with a motion capture system. An autoencoder subnet is employed for reducing the dimensionality of captured sequences of human motions, complemented with a mixture density subnet for probabilistic modeling of the motion data using a mixture of Gaussian distributions. The proposed neural network architecture produced a model for sets of human motions represented with a mixture of Gaussian density functions. The mean log-likelihood of observed sequences was employed as a performance metric in evaluating the consistency of a subject's performance relative to the reference dataset of motions. A publically available dataset of human motions captured with Microsoft Kinect was used for validation of the proposed method. The article presents a novel approach for modeling and evaluation of human motions with a potential application in home-based physical therapy and rehabilitation. The described approach employs the recent progress in the field of machine learning and neural networks in developing a parametric model of human motions, by exploiting the representational power of these algorithms to encode nonlinear input-output dependencies over long temporal horizons.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wheeler, F.; Wessol, D.; Atkinson, C.

    During the past few years, murine and large animal research, as well as human studies have provided data to the point where human clinical trials have been initiated at the BMRR using BPA-F for gliomas and at the Massachusetts Institute of Technology Reactor (MITR) using BPA for melanomas of the extremeties. It is expected that glioma trials using BSH will proceed soon at the Petten High Flux Reactor (HFR) in the Netherlands. The first human glioma epithermal boron neutron capture therapy application was performed at the BMRR in the fall of 1994. This was a collaborative effort by BNL, Bethmore » Israel Manhattan hospital, and INEL. The INEL planning system was chosen to perform dose predictions for this application.« less

  9. Magnetic nanoparticles for efficient cell transduction with Semliki Forest virus.

    PubMed

    Kurena, Baiba; Vežāne, Aleksandra; Skrastiņa, Dace; Trofimova, Olga; Zajakina, Anna

    2017-07-01

    Semliki Forest virus (SFV) is a potential cancer gene therapy vector capable of providing high and transient expression of heterologous proteins in mammalian cells. However, SFV has shown suboptimal transduction levels in several cancer cell types as well as wide biodistribution of SFV has been observed after in vivo applications. Magnetic nanoparticles (MNPs) have been shown to increase cell transduction with several viral vectors in vitro under an external magnetic field and enhance magnetically guided viral vector delivery. Here, we examined a panel of MNPs for enhanced cancer cell transduction with SFV vector. Magneto-transduction using positively charged MNPs increased Semliki Forest virus transduction in TS/A mouse mammary carcinoma cells in vitro in the presence of fetal bovine serum. Positively charged MNPs efficiently captured SFV particles independently of capturing medium, and MNPs-SFV complexes were successfully separated from suspension by magnetic precipitation. These results reveal the potential application of MNPs for enhanced gene delivery by SFV vector as well as proposes magnetic precipitation for efficient concentration of SFV particles from different media. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Synthesis of internally functionalized silica nanoparticles for theranostic applications

    NASA Astrophysics Data System (ADS)

    Walton, Nathan Isaac

    This thesis addresses the synthesis and characterization of novel inorganic silica nanoparticle hybrids. It focuses in large part on their potential applications in the medical field. Silica acts as a useful carrier for a variety of compounds and this thesis silica will demonstrate its use as a carrier for boron or gadolinium. Boron-10 and gadolinium-157 have been suggested for the radiological treatment of tumor cells through the process called neutron capture therapy (NCT). Gadolinium is also commonly used as a Magnetic Resonance Imaging (MRI) contrast agent. Particles that carry it have potential theranostic applications of both imaging and treating tumors. Chapter 1 presents a background on synthetic strategies and usages of silica nanoparticles, and NCT theory. Chapter 2 describes a procedure to create mesoporous metal chelating silica nanoparticles, mDTTA. This is achieved via a co-condensation of tetraethoxysilane (TEOS) and 3-trimethoxysilyl-propyl diethylenetriamine (SiDETA) followed by a post-synthesis modification step with bromoacetic acid (BrAA). These particles have a large surface area and well-defined pores of ~2 nm. The mDTTA nanoparticles were used to chelate the copper(II), cobalt(II) and gadolinium(III). The chelating of gadolinium is the most interesting since it can be used as a MRI contrast agent and a neutron capture therapeutic. The synthetic procedure developed also allows for the attachment of a fluorophore that gives the gadolinium chelating mDTTA nanoparticles a dual imaging modality. Chapter 3 presents the synthetic method used to produce two classes of large surface area organically modified silica (ORMOSIL) nanoparticles. Condensating the organosilane vinyltrimethoxysilane in a micellar solution results in nanoparticles that are either surface rough (raspberry-like) or mesoporous nanoparticles, which prior to this thesis has not been demonstrated in ORMOSIL chemistry. Furthermore, the vinyl functionalities are modified, using hydroboration, to make the nanoparticles into water-dispersible boron carriers that also have potential boron neutron capture therapy (BNCT) applications. Lastly, Chapter 4 provides a general description of NCT, specifically that involving boron-10 and gadolinium-157. It further describes the synthetic methodology used in producing fatty acid coated boron nanoparticles (BNPs). The BNPs are encapsulated with silica to add a hydrophilic shell so that they can potentially be used in biological systems as BNCT agents. The silica shell is also modified with a fluorophore, dansyl chloride, so that the particle hybrid could be imaged during cell studies.

  11. Boron neutron capture therapy as new treatment for clear cell sarcoma: trial on different animal model.

    PubMed

    Andoh, Tooru; Fujimoto, Takuya; Sudo, Tamotsu; Suzuki, Minoru; Sakurai, Yoshinori; Sakuma, Toshiko; Moritake, Hiroshi; Sugimoto, Tohru; Takeuchi, Tamotsu; Sonobe, Hiroshi; Epstein, Alan L; Fukumori, Yoshinobu; Ono, Koji; Ichikawa, Hideki

    2014-06-01

    Clear cell sarcoma (CCS) is a rare malignant tumor with a poor prognosis. In our previous study, the tumor disappeared under boron neutron capture therapy (BNCT) on subcutaneously-transplanted CCS-bearing animals. In the present study, the tumor disappeared under this therapy on model mice intramuscularly implanted with three different human CCS cells. BNCT led to the suppression of tumor-growth in each of the different model mice, suggesting its potentiality as an alternative to, or integrative option for, the treatment of CCS. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Accuracy Evaluation of a 3-Dimensional Surface Imaging System for Guidance in Deep-Inspiration Breath-Hold Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alderliesten, Tanja; Sonke, Jan-Jakob; Betgen, Anja

    2013-02-01

    Purpose: To investigate the applicability of 3-dimensional (3D) surface imaging for image guidance in deep-inspiration breath-hold radiation therapy (DIBH-RT) for patients with left-sided breast cancer. For this purpose, setup data based on captured 3D surfaces was compared with setup data based on cone beam computed tomography (CBCT). Methods and Materials: Twenty patients treated with DIBH-RT after breast-conserving surgery (BCS) were included. Before the start of treatment, each patient underwent a breath-hold CT scan for planning purposes. During treatment, dose delivery was preceded by setup verification using CBCT of the left breast. 3D surfaces were captured by a surface imaging systemmore » concurrently with the CBCT scan. Retrospectively, surface registrations were performed for CBCT to CT and for a captured 3D surface to CT. The resulting setup errors were compared with linear regression analysis. For the differences between setup errors, group mean, systematic error, random error, and 95% limits of agreement were calculated. Furthermore, receiver operating characteristic (ROC) analysis was performed. Results: Good correlation between setup errors was found: R{sup 2}=0.70, 0.90, 0.82 in left-right, craniocaudal, and anterior-posterior directions, respectively. Systematic errors were {<=}0.17 cm in all directions. Random errors were {<=}0.15 cm. The limits of agreement were -0.34-0.48, -0.42-0.39, and -0.52-0.23 cm in left-right, craniocaudal, and anterior-posterior directions, respectively. ROC analysis showed that a threshold between 0.4 and 0.8 cm corresponds to promising true positive rates (0.78-0.95) and false positive rates (0.12-0.28). Conclusions: The results support the application of 3D surface imaging for image guidance in DIBH-RT after BCS.« less

  13. Boronated porhyrins and methods for their use

    DOEpatents

    Miura, Michiko; Shelnutt, John A.; Slatkin, Daniel N.

    1999-03-02

    The present invention covers boronated porphyrins containing multiple carborane cages which selectively accumulate in neoplastic tissue within the irradiation volume and thus can be used in cancer therapies such as boron neutron capture therapy and photodynamic therapy.

  14. The neutron flux monitors from 20 keV to 1 MeV for BNCT: performance study using accelerator-based neutron sources

    NASA Astrophysics Data System (ADS)

    Guan, X. C.; Gong, Y.; Murata, I.; Wang, T. S.

    2018-05-01

    The performance of the neutron flux monitors from 20 keV to 1 MeV developed for boron neutron capture therapy (BNCT) is studied by Monte Carlo simulations using accelerator-based neutron sources (ABNSs). The results show that the performance of the neutron flux monitors is very satisfactory and they can be efficiently used in practical applications to measure the neutron fluxes from 20 keV to 1 MeV of ABNSs for BNCT to high accuracy.

  15. Physics of epi-thermal boron neutron capture therapy (epi-thermal BNCT).

    PubMed

    Seki, Ryoichi; Wakisaka, Yushi; Morimoto, Nami; Takashina, Masaaki; Koizumi, Masahiko; Toki, Hiroshi; Fukuda, Mitsuhiro

    2017-12-01

    The physics of epi-thermal neutrons in the human body is discussed in the effort to clarify the nature of the unique radiologic properties of boron neutron capture therapy (BNCT). This discussion leads to the computational method of Monte Carlo simulation in BNCT. The method is discussed through two examples based on model phantoms. The physics is kept at an introductory level in the discussion in this tutorial review.

  16. A comparison of the COG and MCNP codes in computational neutron capture therapy modeling, Part II: gadolinium neutron capture therapy models and therapeutic effects.

    PubMed

    Wangerin, K; Culbertson, C N; Jevremovic, T

    2005-08-01

    The goal of this study was to evaluate the COG Monte Carlo radiation transport code, developed and tested by Lawrence Livermore National Laboratory, for gadolinium neutron capture therapy (GdNCT) related modeling. The validity of COG NCT model has been established for this model, and here the calculation was extended to analyze the effect of various gadolinium concentrations on dose distribution and cell-kill effect of the GdNCT modality and to determine the optimum therapeutic conditions for treating brain cancers. The computational results were compared with the widely used MCNP code. The differences between the COG and MCNP predictions were generally small and suggest that the COG code can be applied to similar research problems in NCT. Results for this study also showed that a concentration of 100 ppm gadolinium in the tumor was most beneficial when using an epithermal neutron beam.

  17. Boronated porhyrins and methods for their use

    DOEpatents

    Miura, M.; Shelnutt, J.A.; Slatkin, D.N.

    1999-03-02

    The present invention covers boronated porphyrins containing multiple carborane cages which selectively accumulate in neoplastic tissue within the irradiation volume and thus can be used in cancer therapies such as boron neutron capture therapy and photodynamic therapy. 3 figs.

  18. A new electrocardiogram algorithm for diagnosing loss of ventricular capture during cardiac resynchronisation therapy.

    PubMed

    Ganière, Vincent; Domenichini, Giulia; Niculescu, Viviana; Cassagneau, Romain; Defaye, Pascal; Burri, Haran

    2013-03-01

    The prerequisite for cardiac resynchronization therapy (CRT) is ventricular capture, which may be verified by analysis of the surface electrocardiogram (ECG). Few algorithms exist to diagnose loss of ventricular capture. Electrocardiograms from 126 CRT patients were analysed during biventricular (BV), right ventricular (RV), and left ventricular (LV) pacing. An algorithm evaluating QRS narrowing in the limb leads and increasing negativity in lead I to diagnose changes in ventricular capture was devised, prospectively validated, and compared with two existing algorithms. Performance of the algorithm according to ventricular lead position was also assessed. Our algorithm had an accuracy of 88% to correctly identify the changes in ventricular capture (either loss or gain of RV or LV capture). The algorithm had a sensitivity of 94% and a specificity of 96% with an accuracy of 96% for identifying loss of LV capture (the most clinically relevant change), and compared favourably with the existing algorithms. Performance of the algorithms was not significantly affected by RV or LV lead position. A simple two-step algorithm evaluating QRS width in the limb leads and changes in negativity in lead I can accurately diagnose the lead responsible for intermittent loss of ventricular capture in CRT. This simple tool may be of particular use outside the setting of specialized device clinics.

  19. Folate receptor-mediated boron-10 containing carbon nanoparticles as potential delivery vehicles for boron neutron capture therapy of nonfunctional pituitary adenomas.

    PubMed

    Dai, Congxin; Cai, Feng; Hwang, Kuo Chu; Zhou, Yongmao; Zhang, Zizhu; Liu, Xiaohai; Ma, Sihai; Yang, Yakun; Yao, Yong; Feng, Ming; Bao, Xinjie; Li, Guilin; Wei, Junji; Jiao, Yonghui; Wei, Zhenqing; Ma, Wenbin; Wang, Renzhi

    2013-02-01

    Invasive nonfunctional pituitary adenomas (NFPAs) are difficult to completely resect and often develop tumor recurrence after initial surgery. Currently, no medications are clinically effective in the control of NFPA. Although radiation therapy and radiosurgery are useful to prevent tumor regrowth, they are frequently withheld because of severe complications. Boron neutron capture therapy (BNCT) is a binary radiotherapy that selectively and maximally damages tumor cells without harming the surrounding normal tissue. Folate receptor (FR)-targeted boron-10 containing carbon nanoparticles is a novel boron delivery agent that can be selectively taken up by FR-expressing cells via FR-mediated endocytosis. In this study, FR-targeted boron-10 containing carbon nanoparticles were selectively taken up by NFPAs cells expressing FR but not other types of non-FR expressing pituitary adenomas. After incubation with boron-10 containing carbon nanoparticles and following irradiation with thermal neutrons, the cell viability of NFPAs was significantly decreased, while apoptotic cells were simultaneously increased. However, cells administered the same dose of FR-targeted boron-10 containing carbon nanoparticles without neutron irradiation or received the same neutron irradiation alone did not show significant decrease in cell viability or increase in apoptotic cells. The expression of Bcl-2 was down-regulated and the expression of Bax was up-regulated in NFPAs after treatment with FR-mediated BNCT. In conclusion, FR-targeted boron-10 containing carbon nanoparticles may be an ideal delivery system of boron to NFPAs cells for BNCT. Furthermore, our study also provides a novel insight into therapeutic strategies for invasive NFPA refractory to conventional therapy, while exploring these new applications of BNCT for tumors, especially benign tumors.

  20. Electrostatic design and beam transport for a folded tandem electrostatic quadrupole accelerator facility for accelerator-based boron neutron capture therapy.

    PubMed

    Vento, V Thatar; Bergueiro, J; Cartelli, D; Valda, A A; Kreiner, A J

    2011-12-01

    Within the frame of an ongoing project to develop a folded Tandem-Electrostatic-Quadrupole (TESQ) accelerator facility for Accelerator-Based Boron Neutron Capture Therapy (AB-BNCT), we discuss here the electrostatic design of the machine, including the accelerator tubes with electrostatic quadrupoles and the simulations for the transport and acceleration of a high intensity beam. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. [Possibilities of boron neutron capture therapy in the treatment of malignant brain tumors].

    PubMed

    Kanygin, V V; Kichigin, A I; Gubanova, N V; Taskaev, S Yu

    2015-01-01

    Boron neutron capture therapy (BNCT) that is of the highest attractiveness due to its selective action directly on malignant tumor cells is a promising approach to treating cancers. Clinical interest in BNCT focuses in neuro-oncology on therapy for gliomas, glioblastoma in particular, and BNCT may be used in brain metastatic involvement. This needs an epithermal neutron source that complies with the requirements for BNCT, as well as a 10B-containing agent that will selectively accumulate in tumor tissue. The introduction of BNCT into clinical practice to treat patients with glial tumors will be able to enhance therapeutic efficiency.

  2. Validation and Comparison of the Therapeutic Efficacy of Boron Neutron Capture Therapy Mediated By Boron-Rich Liposomes in Multiple Murine Tumor Models

    DOE PAGES

    Maitz, Charles A.; Khan, Aslam A.; Kueffer, Peter J.; ...

    2017-08-01

    Boron neutron capture therapy (BNCT) was performed at the University of Missouri Research Reactor in mice bearing CT26 colon carcinoma flank tumors and the results were compared with previously performed studies with mice bearing EMT6 breast cancer flank tumors. We implanted mice with CT26 tumors subcutaneously in the caudal flank and were given two separate tail vein injections of unilamellar liposomes composed of cholesterol, 1,2-distearoyl-sn-glycer-3-phosphocholine, and K[nido-7-CH 3(CH 2) 15–7,8-C 2B 9H 11] in the lipid bilayer and encapsulated Na 3[1-(2`-B 10H 9)-2-NH 3B 10H 8] within the liposomal core. Mice were irradiated 30 hours after the second injection inmore » a thermal neutron beam for various lengths of time. The tumor size was monitored daily for 72 days. In spite of relatively lower tumor boron concentrations, as compared to EMT6 tumors, a 45 minute neutron irradiation BNCT resulted in complete resolution of the tumors in 50% of treated mice, 50% of which never recurred. Median time to tumor volume tripling was 38 days in BNCT treated mice, 17 days in neutron-irradiated mice given no boron compounds, and 4 days in untreated controls. Tumor response in mice with CT26 colon carcinoma was markedly more pronounced than in previous reports of mice with EMT6 tumors, a difference which increased with dose. The slope of the dose response curve of CT26 colon carcinoma tumors is 1.05 times tumor growth delay per Gy compared to 0.09 times tumor growth delay per Gy for EMT6 tumors, indicating that inherent radiosensitivity of tumors plays a role in boron neutron capture therapy and should be considered in the development of clinical applications of BNCT in animals and man.« less

  3. Validation and Comparison of the Therapeutic Efficacy of Boron Neutron Capture Therapy Mediated By Boron-Rich Liposomes in Multiple Murine Tumor Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maitz, Charles A.; Khan, Aslam A.; Kueffer, Peter J.

    Boron neutron capture therapy (BNCT) was performed at the University of Missouri Research Reactor in mice bearing CT26 colon carcinoma flank tumors and the results were compared with previously performed studies with mice bearing EMT6 breast cancer flank tumors. We implanted mice with CT26 tumors subcutaneously in the caudal flank and were given two separate tail vein injections of unilamellar liposomes composed of cholesterol, 1,2-distearoyl-sn-glycer-3-phosphocholine, and K[nido-7-CH 3(CH 2) 15–7,8-C 2B 9H 11] in the lipid bilayer and encapsulated Na 3[1-(2`-B 10H 9)-2-NH 3B 10H 8] within the liposomal core. Mice were irradiated 30 hours after the second injection inmore » a thermal neutron beam for various lengths of time. The tumor size was monitored daily for 72 days. In spite of relatively lower tumor boron concentrations, as compared to EMT6 tumors, a 45 minute neutron irradiation BNCT resulted in complete resolution of the tumors in 50% of treated mice, 50% of which never recurred. Median time to tumor volume tripling was 38 days in BNCT treated mice, 17 days in neutron-irradiated mice given no boron compounds, and 4 days in untreated controls. Tumor response in mice with CT26 colon carcinoma was markedly more pronounced than in previous reports of mice with EMT6 tumors, a difference which increased with dose. The slope of the dose response curve of CT26 colon carcinoma tumors is 1.05 times tumor growth delay per Gy compared to 0.09 times tumor growth delay per Gy for EMT6 tumors, indicating that inherent radiosensitivity of tumors plays a role in boron neutron capture therapy and should be considered in the development of clinical applications of BNCT in animals and man.« less

  4. Dosimetry and radiobiology at the new RA-3 reactor boron neutron capture therapy (BNCT) facility: application to the treatment of experimental oral cancer.

    PubMed

    Pozzi, E; Nigg, D W; Miller, M; Thorp, S I; Heber, E M; Zarza, L; Estryk, G; Monti Hughes, A; Molinari, A J; Garabalino, M; Itoiz, M E; Aromando, R F; Quintana, J; Trivillin, V A; Schwint, A E

    2009-07-01

    The National Atomic Energy Commission of Argentina (CNEA) constructed a novel thermal neutron source for use in boron neutron capture therapy (BNCT) applications at the RA-3 research reactor facility located in Buenos Aires. The aim of the present study was to perform a dosimetric characterization of the facility and undertake radiobiological studies of BNCT in an experimental model of oral cancer in the hamster cheek pouch. The free-field thermal flux was 7.1 x 10(9) n cm(-2)s(-1) and the fast neutron flux was 2.5 x 10(6) n cm(-2)s(-1), indicating a very well-thermalized neutron field with negligible fast neutron dose. For radiobiological studies it was necessary to shield the body of the hamster from the neutron flux while exposing the everted cheek pouch bearing the tumors. To that end we developed a lithium (enriched to 95% in (6)Li) carbonate enclosure. Groups of tumor-bearing hamsters were submitted to BPA-BNCT, GB-10-BNCT, (GB-10+BPA)-BNCT or beam only treatments. Normal (non-cancerized) hamsters were treated similarly to evaluate normal tissue radiotoxicity. The total physical dose delivered to tumor with the BNCT treatments ranged from 6 to 8.5 Gy. Tumor control at 30 days ranged from 73% to 85%, with no normal tissue radiotoxicity. Significant but reversible mucositis in precancerous tissue surrounding tumors was associated to BPA-BNCT. The therapeutic success of different BNCT protocols in treating experimental oral cancer at this novel facility was unequivocally demonstrated.

  5. An innovative pre-targeting strategy for tumor cell specific imaging and therapy

    NASA Astrophysics Data System (ADS)

    Qin, Si-Yong; Peng, Meng-Yun; Rong, Lei; Jia, Hui-Zhen; Chen, Si; Cheng, Si-Xue; Feng, Jun; Zhang, Xian-Zheng

    2015-08-01

    A programmed pre-targeting system for tumor cell imaging and targeting therapy was established based on the ``biotin-avidin'' interaction. In this programmed functional system, transferrin-biotin can be actively captured by tumor cells with the overexpression of transferrin receptors, thus achieving the pre-targeting modality. Depending upon avidin-biotin recognition, the attachment of multivalent FITC-avidin to biotinylated tumor cells not only offered the rapid fluorescence labelling, but also endowed the pre-targeted cells with targeting sites for the specifically designed biotinylated peptide nano-drug. Owing to the successful pre-targeting, tumorous HepG2 and HeLa cells were effectively distinguished from the normal 3T3 cells via fluorescence imaging. In addition, the self-assembled peptide nano-drug resulted in enhanced cell apoptosis in the observed HepG2 cells. The tumor cell specific pre-targeting strategy is applicable for a variety of different imaging and therapeutic agents for tumor treatments.A programmed pre-targeting system for tumor cell imaging and targeting therapy was established based on the ``biotin-avidin'' interaction. In this programmed functional system, transferrin-biotin can be actively captured by tumor cells with the overexpression of transferrin receptors, thus achieving the pre-targeting modality. Depending upon avidin-biotin recognition, the attachment of multivalent FITC-avidin to biotinylated tumor cells not only offered the rapid fluorescence labelling, but also endowed the pre-targeted cells with targeting sites for the specifically designed biotinylated peptide nano-drug. Owing to the successful pre-targeting, tumorous HepG2 and HeLa cells were effectively distinguished from the normal 3T3 cells via fluorescence imaging. In addition, the self-assembled peptide nano-drug resulted in enhanced cell apoptosis in the observed HepG2 cells. The tumor cell specific pre-targeting strategy is applicable for a variety of different imaging and therapeutic agents for tumor treatments. Electronic supplementary information (ESI) available: Experimental details, peptide structures, molecular weights, and additional data. See DOI: 10.1039/c5nr03862f

  6. Mathematical modelling of prostate cancer growth and its application to hormone therapy.

    PubMed

    Tanaka, Gouhei; Hirata, Yoshito; Goldenberg, S Larry; Bruchovsky, Nicholas; Aihara, Kazuyuki

    2010-11-13

    Hormone therapy in the form of androgen deprivation is a major treatment for advanced prostate cancer. However, if such therapy is overly prolonged, tumour cells may become resistant to this treatment and result in recurrent fatal disease. Long-term hormone deprivation also is associated with side effects poorly tolerated by patients. In contrast, intermittent hormone therapy with alternating on- and off-treatment periods is a possible clinical strategy to delay progression to hormone-refractory disease with the advantage of reduced side effects during the off-treatment periods. In this paper, we first overview previous studies on mathematical modelling of prostate tumour growth under intermittent hormone therapy. The model is categorized into a hybrid dynamical system because switching between on-treatment and off-treatment intervals is treated in addition to continuous dynamics of tumour growth. Next, we present an extended model of stochastic differential equations and examine how well the model is able to capture the characteristics of authentic serum prostate-specific antigen (PSA) data. We also highlight recent advances in time-series analysis and prediction of changes in serum PSA concentrations. Finally, we discuss practical issues to be considered towards establishment of mathematical model-based tailor-made medicine, which defines how to realize personalized hormone therapy for individual patients based on monitored serum PSA levels.

  7. Clinical trials needed to evaluate compression therapy in breast cancer related lymphedema (BCRL). Proposals from an expert group.

    PubMed

    Partsch, H; Stout, N; Forner-Cordero, I; Flour, M; Moffatt, C; Szuba, A; Milic, D; Szolnoky, G; Brorson, H; Abel, M; Schuren, J; Schingale, F; Vignes, S; Piller, N; Döller, W

    2010-10-01

    A mainstay of lymphedema management involves the use of compression therapy. Compression therapy application is variable at different levels of disease severity. Evidence is scant to direct clinicians in best practice regarding compression therapy use. Further, compression clinical trials are fragmented and poorly extrapolable to the greater population. An ideal construct for conducting clinical trials in regards to compression therapy will promote parallel global initiatives based on a standard research agenda. The purpose of this article is to review current evidence in practice regarding compression therapy for BCRL management and based on this evidence, offer an expert consensus recommendation for a research agenda and prescriptive trials. Recommendations herein focus solely on compression interventions. This document represents the proceedings of a session organized by the International Compression Club (ICC) in June 2009 in Ponzano (Veneto, Italy). The purpose of the meeting was to enable a group of experts to discuss the existing evidence for compression treatment in breast cancer related lymphedema (BCRL) concentrating on areas where randomized controlled trials (RCTs) are lacking. The current body of research suggests efficacy of compression interventions in the treatment and management of lymphedema. However, studies to date have failed to adequately address various forms of compression therapy and their optimal application in BCRL. We offer recommendations for standardized compression research trials for prophylaxis of arm lymphedema and for the management of chronic BCRL. Suggestions are also made regarding; inclusion and exclusion criteria, measurement methodology and additional variables of interest for researchers to capture. This document should inform future research trials in compression therapy and serve as a guide to clinical researchers, industry researchers and lymphologists regarding the strengths, weaknesses and shortcomings of the current literature. By providing this construct for research trials, the authors aim to support evidence-based therapy interventions, promote a cohesive, standardized and informative body of literature to enhance clinical outcomes, improve the quality of future research trials, inform industry innovation and guide policy related to BCRL.

  8. Synthesis and in vitro evaluation of thiododecaborated α, α- cycloalkylamino acids for the treatment of malignant brain tumors by boron neutron capture therapy.

    PubMed

    Hattori, Yoshihide; Kusaka, Shintaro; Mukumoto, Mari; Ishimura, Miki; Ohta, Yoichiro; Takenaka, Hiroshi; Uehara, Kouki; Asano, Tomoyuki; Suzuki, Minoru; Masunaga, Shin-Ichiro; Ono, Koji; Tanimori, Shinji; Kirihata, Mitsunori

    2014-12-01

    Boron-neutron capture therapy (BNCT) is an attractive technique for cancer treatment. As such, α, α-cycloalkyl amino acids containing thiododecaborate ([B12H11](2-)-S-) units were designed and synthesized as novel boron delivery agents for BNCT. In the present study, new thiododecaborate α, α-cycloalkyl amino acids were synthesized, and biological evaluation of the boron compounds as boron carrier for BNCT was carried out.

  9. Boron neutron capture therapy for oral precancer: proof of principle in an experimental animal model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A. Monti Hughes; ECC Pozzi; S. Thorp

    Field-cancerized tissue can give rise to second primary tumours, causing therapeutic failure. Boron neutron capture therapy (BNCT) is based on biological targeting and would serve to treat undetectable foci of malignant transformation. The aim of this study was to optimize BNCT for the integral treatment for oral cancer, with particular emphasis on the inhibitory effect on tumour development originating in precancerous conditions, and radiotoxicity of different BNCT protocols in a hamster cheek pouch oral precancer model.

  10. The use of video capture virtual reality in burn rehabilitation: the possibilities.

    PubMed

    Haik, Josef; Tessone, Ariel; Nota, Ayala; Mendes, David; Raz, Liat; Goldan, Oren; Regev, Elli; Winkler, Eyal; Mor, Elisheva; Orenstein, Arie; Hollombe, Ilana

    2006-01-01

    We independently explored the use of the Sony PlayStation II EyeToy (Sony Corporation, Foster City, CA) as a tool for use in the rehabilitation of patients with severe burns. Intensive occupational and physical therapy is crucial in minimizing and preventing long-term disability for the burn patient; however, the therapist faces a difficult challenge combating the agonizing pain experienced by the patient during therapy. The Sony PlayStation II EyeToy is a projected, video-capture system that, although initially developed as a gaming environment for children, may be a useful application in a rehabilitative context. As compared with other virtual reality systems the EyeToy is an efficient rehabilitation tool that is sold commercially at a relatively low cost. This report presents the potential advantages for use of the EyeToy as an innovative rehabilitative tool with mitigating effects on pain in burn rehabilitation. This new technology represents a challenging and motivating way for the patient to immerse himself or herself in an alternate reality while undergoing treatment, thereby reducing the pain and discomfort he or she experiences. This simple, affordable technique may prove to heighten the level of patient cooperation and therefore speed the process of rehabilitation and return of functional ability.

  11. Intracellular delivery and passive tumor targeting of a self-assembled nanogel containing carborane clusters for boron neutron capture therapy.

    PubMed

    Kawasaki, Riku; Sasaki, Yoshihiro; Akiyoshi, Kazunari

    2017-01-29

    Boron neutron capture therapy, based on the release of thermal neutron irradiation from boron, is a targeted radiation therapy for cancer. Targeted and sufficient accumulation of boron in tumor cells to achieve cytotoxic efficacy and reduce off-target effects remains a challenge. Carborane has been investigated for use as a delivery agent in boron neutron capture therapy because of its high boron content and chemical stability; however, it is cytotoxic, making safe delivery difficult. The aim of this study was to investigate the potential of carborane-bearing pullulan nanogels to safely and effectively deliver boron to tumor cells in vitro and in vivo and, consequently, assess their potential as a boron neutron capture therapeutic. Murine fibrosarcoma cells (CMS5a) were used for in vitro investigations of nanogel cytotoxicity, cell uptake. A mouse fibrosarcoma xenograft model was used to investigate the bio-distribution of nanogels after intravenous administration. The nanogels produced no apparent cytotoxicity and underwent cell uptake in CMS5a cells after a 24 h incubation at up to 2000 μg/mL and 400 μg/mL, respectively. The internalized nanogels were localized around the nuclear membrane. The nanogels were administered intravenously to mice bearing fibrosarcoma xenografts. Nanogel tumor localization likely occurred through the enhanced permeation and retention effect. The nanogels successfully reduced the cytotoxicity of carborane, were internalized into tumor cells, acted as a dual-delivery therapeutic and accumulated in tumors in vivo. Consequently, they demonstrate significant potential as a boron neutron capture therapeutic. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Strategies to Improve Cancer Photothermal Therapy Mediated by Nanomaterials.

    PubMed

    de Melo-Diogo, Duarte; Pais-Silva, Cleide; Dias, Diana R; Moreira, André F; Correia, Ilídio J

    2017-05-01

    The deployment of hyperthermia-based treatments for cancer therapy has captured the attention of different researchers worldwide. In particular, the application of light-responsive nanomaterials to mediate hyperthermia has revealed promising results in several pre-clinical assays. Unlike conventional therapies, these nanostructures can display a preferential tumor accumulation and thus mediate, upon irradiation with near-infrared light, a selective hyperthermic effect with temporal resolution. Different types of nanomaterials such as those based on gold, carbon, copper, molybdenum, tungsten, iron, palladium and conjugated polymers have been used for this photothermal modality. This progress report summarizes the different strategies that have been applied so far for increasing the efficacy of the photothermal therapeutic effect mediated by nanomaterials, namely those that improve the accumulation of nanomaterials in tumors (e.g. by changing the corona composition or through the functionalization with targeting ligands), increase nanomaterials' intrinsic capacity to generate photoinduced heat (e.g. by synthesizing new nanomaterials or assembling nanostructures) or by optimizing the parameters related to the laser light used in the irradiation process (e.g. by modulating the radiation wavelength). Overall, the development of new strategies or the optimization and combination of the existing ones will surely give a major contribution for the application of nanomaterials in cancer PTT. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Design of a boron neutron capture enhanced fast neutron therapy assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Zhonglu

    The use of boron neutron capture to boost tumor dose in fast neutron therapy has been investigated at several fast neutron therapy centers worldwide. This treatment is termed boron neutron capture enhanced fast neutron therapy (BNCEFNT). It is a combination of boron neutron capture therapy (BNCT) and fast neutron therapy (FNT). It is believed that BNCEFNT may be useful in the treatment of some radioresistant brain tumors, such as glioblastoma multiform (GBM). A boron neutron capture enhanced fast neutron therapy assembly has been designed for the Fermilab Neutron Therapy Facility (NTF). This assembly uses a tungsten filter and collimator nearmore » the patient's head, with a graphite reflector surrounding the head to significantly increase the dose due to boron neutron capture reactions. The assembly was designed using Monte Carlo radiation transport code MCNP version 5 for a standard 20x20 cm 2 treatment beam. The calculated boron dose enhancement at 5.7-cm depth in a water-filled head phantom in the assembly with a 5x5 cm 2 collimation was 21.9% per 100-ppm 10B for a 5.0-cm tungsten filter and 29.8% for a 8.5-cm tungsten filter. The corresponding dose rate for the 5.0-cm and 8.5-cm thick filters were 0.221 and 0.127 Gy/min, respectively; about 48.5% and 27.9% of the dose rate of the standard 10x10 cm 2 fast neutron treatment beam. To validate the design calculations, a simplified BNCEFNT assembly was built using four lead bricks to form a 5x5 cm 2 collimator. Five 1.0-cm thick 20x20 cm 2 tungsten plates were used to obtain different filter thicknesses and graphite bricks/blocks were used to form a reflector. Measurements of the dose enhancement of the simplified assembly in a water-filled head phantom were performed using a pair of tissue-equivalent ion chambers. One of the ion chambers is loaded with 1000-ppm natural boron (184-ppm 10B) to measure dose due to boron neutron capture. The measured dose enhancement at 5.0-cm depth in the head phantom for the 5.0-cm thick tungsten filter is (16.6 ± 1.8)%, which agrees well with the MCNP simulation of the simplified BNCEFNT assembly, (16.4 ± 0.5)%. The error in the calculated dose enhancement only considers the statistical uncertainties. The total dose rate measured at 5.0-cm depth using the non-borated ion chamber is (0.765 ± 0.076) Gy/MU, about 61% of the fast neutron standard dose rate (1.255Gy/MU) at 5.0-cm depth for the standard 10x10 cm 2 treatment beam. The increased doses to other organs due to the use of the BNCEFNT assembly were calculated using MCNP5 and a MIRD phantom. The activities of the activation products produced in the BNCEFNT assembly after neutron beam delivery were computed. The photon ambient dose rate due to the radioactive activation products was also estimated.« less

  14. Boron Neutron Capture Therapty (BNCT) in an Oral Precancer Model: Therapeutic Benefits and Potential Toxicity of a Double Application of BNCT with a Six-Week Interval

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andrea Monti Hughes; Emiliano C.C. Pozzi; Elisa M. Heber

    Given the clinical relevance of locoregional recurrences in head and neck cancer, we developed a novel experimental model of premalignant tissue in the hamster cheek pouch for long-term studies and demonstrated the partial inhibitory effect of a single application of Boron Neutron Capture Therapy (BNCT) on tumor development from premalignant tissue. The aim of the present study was to evaluate the effect of a double application of BNCT with a 6 week interval in terms of inhibitory effect on tumor development, toxicity and DNA synthesis. We performed a double application, 6 weeks apart, of (1) BNCT mediated by boronophenylalanine (BPA-BNCT);more » (2) BNCT mediated by the combined application of decahydrodecaborate (GB-10) and BPA [(GB-10 + BPA)-BNCT] or (3) beam-only, at RA-3 nuclear reactor and followed the animals for 8 months. The control group was cancerized and sham-irradiated. BPA-BNCT, (GB- 10 + BPA)-BNCT and beam-only induced a reduction in tumor development from premalignant tissue that persisted until 8, 3, and 2 months respectively. An early maximum inhibition of 100% was observed for all 3 protocols. No normal tissue radiotoxicity was detected. Reversible mucositis was observed in premalignant tissue, peaking at 1 week and resolving by the third week after each irradiation. Mucositis after the second application was not exacerbated by the first application. DNA synthesis was significantly reduced in premalignant tissue 8 months post-BNCT. A double application of BPA-BNCT and (GB-10 + BPA)-BNCT, 6 weeks apart, could be used therapeutically at no additional cost in terms of radiotoxicity in normal and dose-limiting tissues.« less

  15. Medical Application of the SARAF-Proton/Deuteron 40 MeV Superconducting Linac

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Halfon, Shlomi

    2007-11-26

    The Soreq Applied Research Accelerator Facility (SARAF) is based on a superconducting linear accelerator currently being built at the Soreq research center (Israel). The SARAF is planned to generate a 2 mA 4 MeV proton beam during its first year of operation and up to 40 MeV proton or deuteron beam in 2012. The high intensity beam, together with the linac ability to adjust the ion energy provides opportunities for medical research, such as Boron Neutron Capture Therapy (BNCT) and the production of medical radioisotopes, for instance {sup 103}Pd for prostate brachytherapy.

  16. SERA -- An advanced treatment planning system for neutron therapy and BNCT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nigg, D.W.; Wemple, C.A.; Wessol, D.E.

    1999-09-01

    Detailed treatment planning calculations on a patient-specific basis are required for boron neutron capture therapy (BNCT). Two integrated treatment planning systems developed specifically for BNCT have been in clinical use in the United States over the past few years. The MacNCTPLAN BNCT treatment planning system is used in the clinical BNCT trials that are underway at the Massachusetts Institute of Technology. A second system, BNCT{_}rtpe (BNCT radiation therapy planning environment), developed independently by the Idaho national Engineering and Environmental Laboratory (INEEL) in collaboration with Montana State University (MSU), is used for treatment planning in the current series of BNCT clinicalmore » trials for glioblastoma at Brookhaven National Laboratory (BNL). This latter system is also licensed for use at several other BNCT research facilities worldwide. Although the currently available BNCT planning systems have served their purpose well, they suffer from somewhat long computation times (2 to 3 CPU-hours or more per field) relative to standard photon therapy planning software. This is largely due to the need for explicit three-dimensional solutions to the relevant transport equations. The simplifying approximations that work well for photon transport computations are not generally applicable to neutron transport computations. Greater computational speeds for BNCT treatment planning must therefore generally be achieved through the application of improved numerical techniques rather than by simplification of the governing equations. Recent efforts at INEEL and MSU have been directed toward this goal. This has resulted in a new paradigm for this type of calculation and the subsequent creation of the new simulation environment for radiotherapy applications (SERA) treatment planning system for BNCT. SERA is currently in initial clinical testing in connection with the trials at BNL, and it is expected to replace the present BNCT{_}rtpe system upon general release during 1999.« less

  17. On the applicability of [18F]FBPA to predict L-BPA concentration after amino acid preloading in HuH-7 liver tumor model and the implication for liver boron neutron capture therapy.

    PubMed

    Grunewald, Catrin; Sauberer, Michael; Filip, Thomas; Wanek, Thomas; Stanek, Johann; Mairinger, Severin; Rollet, Sofia; Kudejova, Petra; Langer, Oliver; Schütz, Christian; Blaickner, Matthias; Kuntner, Claudia

    2017-01-01

    In recent years extra-corporal application of boron neutron capture therapy (BNCT) was evaluated for liver primary tumors or liver metastases. A prerequisite for such a high-risk procedure is proof of preferential delivery and high uptake of a 10 B-pharmaceutical in liver malignancies. In this work we evaluated in a preclinical tumor model if [ 18 F]FBPA tissue distribution measured with PET is able to predict the tissue distribution of [ 10 B]L-BPA. Tumor bearing mice (hepatocellular carcinoma cell line, HuH-7) were either subject of a [ 18 F]FBPA-PET scan with subsequent measurement of radioactivity content in extracted organs using a gamma counter or injected with [ 10 B]L-BPA with tissue samples analyzed by prompt gamma activation analysis (PGAA) or quantitative neutron capture radiography (QNCR). The impact of L-tyrosine, L-DOPA and L-BPA preloading on the tissue distribution of [ 18 F]FBPA and [ 10 B]L-BPA was evaluated and the pharmacokinetics of [ 18 F]FBPA investigated by compartment modeling. We found a significant correlation between [ 18 F]FBPA and [ 10 B]L-BPA uptake in tumors and various organs as well as high accumulation levels in pancreas and kidneys as reported in previous studies. Tumor-to-liver ratios of [ 18 F]FBPA ranged from 1.2 to 1.5. Preloading did not increase the uptake of [ 18 F]FBPA or [ 10 B]L-BPA in any organ and compartment modeling showed no statistically significant differences in [ 18 F]FBPA tumor kinetics. [ 18 F]FBPA-PET predicts [ 10 B]L-BPA concentration after amino acid preloading in HuH-7 hepatocellular carcinoma models. Preloading had no effect on tumor uptake of [ 18 F]FBPA. Despite differences in chemical structure and administered dose [ 18 F]FBPA and [ 10 B]L-BPA demonstrate an equivalent biodistribution in a preclinical tumor model. IMPLICATIONS FOR PATIENT CARE: [ 18 F]FBPA-PET is suitable for treatment planning and dose calculations in BNCT applications for liver malignancies. However, alternative tracers with more favorable tumor-to-liver ratios should be investigated. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Boron Neutron Capture Therapy in the Treatment of Recurrent Laryngeal Cancer.

    PubMed

    Haapaniemi, Aaro; Kankaanranta, Leena; Saat, Riste; Koivunoro, Hanna; Saarilahti, Kauko; Mäkitie, Antti; Atula, Timo; Joensuu, Heikki

    2016-05-01

    To investigate the safety and efficacy of boron neutron capture therapy (BNCT) as a larynx-preserving treatment option for patients with recurrent laryngeal cancer. Six patients with locally recurrent squamous cell laryngeal carcinoma and 3 patients with persistent laryngeal cancer after prior treatment were treated with BNCT at the FiR1 facility (Espoo, Finland) in 2006 to 2012. The patients had received prior radiation therapy with or without concomitant chemotherapy to a cumulative median dose of 66 Gy. The median tumor diameter was 2.9 cm (range, 1.4-10.9 cm) before BNCT. Boron neutron capture therapy was offered on a compassionate basis to patients who either refused laryngectomy (n=7) or had an inoperable tumor (n=2). Boronophenylalanine-fructose (400 mg/kg) was used as the boron carrier and was infused over 2 hours intravenously before neutron irradiation. Six patients received BNCT once and 3 twice. The estimated average gross tumor volume dose ranged from 22 to 38 Gy (W) (mean; 29 Gy [W]). Six of the 8 evaluable patients responded to BNCT; 2 achieved complete and 4 partial response. One patient died early and was not evaluable for response. Most common side effects were stomatitis, fatigue, and oral pain. No life-threatening or grade 4 toxicity was observed. The median time to progression within the target volume was 6.6 months, and the median overall survival time 13.3 months after BNCT. One patient with complete response is alive and disease-free with a functioning larynx 60 months after BNCT. Boron neutron capture therapy given after prior external beam radiation therapy is well tolerated. Most patients responded to BNCT, but long-term survival with larynx preservation was infrequent owing to cancer progression. Selected patients with recurrent laryngeal cancer may benefit from BNCT. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Boron Neutron Capture Therapy in the Treatment of Recurrent Laryngeal Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haapaniemi, Aaro, E-mail: aaro.haapaniemi@hus.fi; Kankaanranta, Leena; Saat, Riste

    2016-05-01

    Purpose: To investigate the safety and efficacy of boron neutron capture therapy (BNCT) as a larynx-preserving treatment option for patients with recurrent laryngeal cancer. Methods and Materials: Six patients with locally recurrent squamous cell laryngeal carcinoma and 3 patients with persistent laryngeal cancer after prior treatment were treated with BNCT at the FiR1 facility (Espoo, Finland) in 2006 to 2012. The patients had received prior radiation therapy with or without concomitant chemotherapy to a cumulative median dose of 66 Gy. The median tumor diameter was 2.9 cm (range, 1.4-10.9 cm) before BNCT. Boron neutron capture therapy was offered on a compassionate basis to patientsmore » who either refused laryngectomy (n=7) or had an inoperable tumor (n=2). Boronophenylalanine-fructose (400 mg/kg) was used as the boron carrier and was infused over 2 hours intravenously before neutron irradiation. Results: Six patients received BNCT once and 3 twice. The estimated average gross tumor volume dose ranged from 22 to 38 Gy (W) (mean; 29 Gy [W]). Six of the 8 evaluable patients responded to BNCT; 2 achieved complete and 4 partial response. One patient died early and was not evaluable for response. Most common side effects were stomatitis, fatigue, and oral pain. No life-threatening or grade 4 toxicity was observed. The median time to progression within the target volume was 6.6 months, and the median overall survival time 13.3 months after BNCT. One patient with complete response is alive and disease-free with a functioning larynx 60 months after BNCT. Conclusions: Boron neutron capture therapy given after prior external beam radiation therapy is well tolerated. Most patients responded to BNCT, but long-term survival with larynx preservation was infrequent owing to cancer progression. Selected patients with recurrent laryngeal cancer may benefit from BNCT.« less

  20. Facile Fabrication of Hierarchically Thermoresponsive Binary Polymer Pattern for Controlled Cell Adhesion.

    PubMed

    Hou, Jianwen; Cui, Lele; Chen, Runhai; Xu, Xiaodong; Chen, Jiayue; Yin, Ligang; Liu, Jingchuan; Shi, Qiang; Yin, Jinghua

    2018-03-01

    A versatile platform allowing capture and detection of normal and dysfunctional cells on the same patterned surface is important for accessing the cellular mechanism, developing diagnostic assays, and implementing therapy. Here, an original and effective method for fabricating binary polymer brushes pattern is developed for controlled cell adhesion. The binary polymer brushes pattern, composed of poly(N-isopropylacrylamide) (PNIPAAm) and poly[poly(ethylene glycol) methyl ether methacrylate] (POEGMA) chains, is simply obtained via a combination of surface-initiated photopolymerization and surface-activated free radical polymerization. This method is unique in that it does not utilize any protecting groups or procedures of backfilling with immobilized initiator. It is demonstrated that the precise and well-defined binary polymer patterns with high resolution are fabricated using this facile method. PNIPAAm chains capture and release cells by thermoresponsiveness, while POEGMA chains possess high capability to capture dysfunctional cells specifically, inducing a switch of normal red blood cells (RBCs) arrays to hemolytic RBCs arrays on the pattern with temperature. This novel platform composed of binary polymer brush pattern is smart and versatile, which opens up pathways to potential applications as microsensors, biochips, and bioassays. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Tandem-ESQ for Accelerator-Based Boron Neutron Capture Therapy (AB-BNCT)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kreiner, A. J.; Escuela de Ciencia y Tecnologia, Universidad de Gral San Martin; CONICET,

    2007-02-12

    A folded tandem, with 1.25 MV terminal voltage, combined with an ElectroStatic Quadrupole (ESQ) chain is being proposed as a machine for Accelerator-Based Boron Neutron Capture Therapy (AB-BNCT). The machine is shown to be capable of accelerating a 30 mA proton beam to 2.5 MeV. These are the specifications needed to produce sufficiently intense and clean epithermal neutron beams, based on the on the 7Li(p,n)7Be reaction, to perform BNCT treatment for deep seated tumors in less than an hour.

  2. Clinical trials of boron neutron capture therapy [in humans] [at Beth Israel Deaconess Medical Center][at Brookhaven National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wallace, Christine

    2001-05-29

    Assessment of research records of Boron Neutron Capture Therapy was conducted at Brookhaven National Laboratory and Beth Israel Deaconess Medical Center using the Code of Federal Regulations, FDA Regulations and Good Clinical Practice Guidelines. Clinical data were collected from subjects' research charts, and differences in conduct of studies at both centers were examined. Records maintained at Brookhaven National Laboratory were not in compliance with regulatory standards. Beth Israel's records followed federal regulations. Deficiencies discovered at both sites are discussed in the reports.

  3. 77 FR 19408 - Dynamic Mobility Applications and Data Capture Management Programs; Notice of Public Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-30

    ... DEPARTMENT OF TRANSPORTATION Dynamic Mobility Applications and Data Capture Management Programs...) Intelligent Transportation System Joint Program Office (ITS JPO) will host a free public meeting to provide stakeholders an update on the Data Capture and Management (DCM) and Dynamic Mobility Applications (DMA...

  4. Metrics for Performance Evaluation of Patient Exercises during Physical Therapy.

    PubMed

    Vakanski, Aleksandar; Ferguson, Jake M; Lee, Stephen

    2017-06-01

    The article proposes a set of metrics for evaluation of patient performance in physical therapy exercises. Taxonomy is employed that classifies the metrics into quantitative and qualitative categories, based on the level of abstraction of the captured motion sequences. Further, the quantitative metrics are classified into model-less and model-based metrics, in reference to whether the evaluation employs the raw measurements of patient performed motions, or whether the evaluation is based on a mathematical model of the motions. The reviewed metrics include root-mean square distance, Kullback Leibler divergence, log-likelihood, heuristic consistency, Fugl-Meyer Assessment, and similar. The metrics are evaluated for a set of five human motions captured with a Kinect sensor. The metrics can potentially be integrated into a system that employs machine learning for modelling and assessment of the consistency of patient performance in home-based therapy setting. Automated performance evaluation can overcome the inherent subjectivity in human performed therapy assessment, and it can increase the adherence to prescribed therapy plans, and reduce healthcare costs.

  5. An innovative pre-targeting strategy for tumor cell specific imaging and therapy.

    PubMed

    Qin, Si-Yong; Peng, Meng-Yun; Rong, Lei; Jia, Hui-Zhen; Chen, Si; Cheng, Si-Xue; Feng, Jun; Zhang, Xian-Zheng

    2015-09-21

    A programmed pre-targeting system for tumor cell imaging and targeting therapy was established based on the "biotin-avidin" interaction. In this programmed functional system, transferrin-biotin can be actively captured by tumor cells with the overexpression of transferrin receptors, thus achieving the pre-targeting modality. Depending upon avidin-biotin recognition, the attachment of multivalent FITC-avidin to biotinylated tumor cells not only offered the rapid fluorescence labelling, but also endowed the pre-targeted cells with targeting sites for the specifically designed biotinylated peptide nano-drug. Owing to the successful pre-targeting, tumorous HepG2 and HeLa cells were effectively distinguished from the normal 3T3 cells via fluorescence imaging. In addition, the self-assembled peptide nano-drug resulted in enhanced cell apoptosis in the observed HepG2 cells. The tumor cell specific pre-targeting strategy is applicable for a variety of different imaging and therapeutic agents for tumor treatments.

  6. Biomimetic strategies for the glioblastoma microenvironment

    NASA Astrophysics Data System (ADS)

    Cha, Junghwa; Kim, Pilnam

    2017-12-01

    Glioblastoma multiforme (GBM) is a devastating type of tumor with high mortality, caused by extensive infiltration into adjacent tissue and rapid recurrence. Most therapies for GBM have focused on the cytotoxicity, and have not targeted GBM spread. However, there have been numerous attempts to improve therapy by addressing GBM invasion, through understanding and mimicking its behavior using three-dimensional (3D) experimental models. Compared with two-dimensional models and in vivo animal models, 3D GBM models can capture the invasive motility of glioma cells within a 3D environment comprising many cellular and non-cellular components. Based on tissue engineering techniques, GBM invasion has been investigated within a biologically relevant environment, from biophysical and biochemical perspectives, to clarify the pro-invasive factors of GBM. This review discusses the recent progress in techniques for modeling the microenvironments of GBM tissue and suggests future directions with respect to recreating the GBM microenvironment and preclinical applications.

  7. First application of dynamic infrared imaging in boron neutron capture therapy for cutaneous malignant melanoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santa Cruz, G. A.; Gonzalez, S. J.; Bertotti, J.

    2009-10-15

    Purpose: The purpose of this study is to assess the potential of dynamic infrared imaging (DIRI) as a functional, noninvasive technique for evaluating the skin acute toxicity and tumor control within the framework of the Argentine boron neutron capture therapy (BNCT) program for cutaneous malignant melanoma. Methods: Two patients enrolled in the Argentine phase I/II BNCT clinical trial for cutaneous malignant melanoma were studied with DIRI. An uncooled infrared camera, providing a video output signal, was employed to register the temperature evolution of the normal skin and tumor regions in patients subjected to a mild local cooling (cold stimulus). Inmore » order to study the spatial correlation between dose and acute skin reactions, three-dimensional representations of the superficial dose delivered to skin were constructed and cameralike projections of the dose distribution were coregistered with visible and infrared images. Results: The main erythematous reaction was observed clinically between the second and fifth week post-BNCT. Concurrently, with its clinical onset, a reactive increase above the basal skin temperature was observed with DIRI in the third week post-BNCT within regions that received therapeutic doses. Melanoma nodules appeared as highly localized hyperthermic regions. 2 min after stimulus, these regions reached a temperature plateau and increased in size. Temperature differences with respect to normal skin up to 10 deg. C were observed in the larger nodules. Conclusions: Preliminary results suggest that DIRI, enhanced by the application of cold stimuli, may provide useful functional information associated with the metabolism and vasculature of tumors and inflammatory processes related to radiation-induced changes in the skin as well. These capabilities are aimed at complementing the clinical observations and standard imaging techniques, such as CT and Doppler ultrasound.« less

  8. Family Therapy Training at the Ackerman Institute: Thoughts of Form and Substance.

    ERIC Educational Resources Information Center

    LaPerriere, Kitty

    1979-01-01

    Presents the history, philosophy, and form of training at the Ackerman Institute for Family Therapy, and attempts to capture the spirit and atmosphere of the program rather than enumerate details. The program teaches family therapy and a systems perspective on human behavior to professionals who have completed basic professional training. (Author)

  9. System and method for delivery of neutron beams for medical therapy

    DOEpatents

    Nigg, David W.; Wemple, Charles A.

    1999-01-01

    A neutron delivery system that provides improved capability for tumor control during medical therapy. The system creates a unique neutron beam that has a bimodal or multi-modal energy spectrum. This unique neutron beam can be used for fast-neutron therapy, boron neutron capture therapy (BNCT), or both. The invention includes both an apparatus and a method for accomplishing the purposes of the invention.

  10. Changes in quality of life as a result of ketogenic diet therapy: A new approach to assessment with the potential for positive therapeutic effects.

    PubMed

    Bruce, Susan; Devlin, Anita; Air, Linda; Cook, Lucy

    2017-01-01

    There are difficulties inherent in measuring Quality of life (QoL) in patients with chronic illness, including agreement on definitions of quality of life and the type of measure used, disease specific or generic. Well validated QoL instruments for epilepsy exist but focus on capturing common themes pertinent to children and families as a group instead of focusing on themes important to individual patients and their families/carers. In addition, it is common for numerous items on these inventories to be left incomplete or responded to with "not applicable" since many of the items are not suitable for children with disabilities and their families. This led us to devise a way to capture individual quality-of-life measures that are linked to parental/carer expectations in families of children undergoing ketogenic diet therapy for epilepsy. As part of our routine clinical assessment, parents/carers were asked to describe what they would like to see happen or change as a result of their child being on ketogenic diet therapy. A simple unstructured form was designed to facilitate the assessment process. Parents were then asked to rate their own QoL against these criteria on a Likert scale of 0-10 prior to commencement of the diet. This assessment was repeated at subsequent visits with parents/carers initially blinded to their original responses. Our assessments indicated that ketogenic diet therapy improves quality of life over a twelve-month period when measured against parental expectations. This ideographic approach has demonstrated changes in parental Qol and parental perceptions of their child's quality of life that would not have been captured by other validated measures. A lengthy questionnaire is avoided and is replaced by a skilled supportive conversation that identifies goals for treatment that are important to parents. This helps parents to reflect on the progress their child makes on the diet by revisiting their previously stated aspirations, and assessing whether they have been achieved. This is particularly helpful for those parents who express a sense of failure or helplessness relating to their child's intractable epilepsy. As a result, future work will center on developing this approach as a clinical tool. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  11. Cyclic-RGDyC functionalized liposomes for dual-targeting of tumor vasculature and cancer cells in glioblastoma: An in vitro boron neutron capture therapy study.

    PubMed

    Kang, Weirong; Svirskis, Darren; Sarojini, Vijayalekshmi; McGregor, Ailsa L; Bevitt, Joseph; Wu, Zimei

    2017-05-30

    The efficacy of boron neutron capture therapy depends on the selective delivery of 10B to the target. Integrins αvβ3 are transmembrane receptors over-expressed in both glioblastoma cells and its neovasculature. In this study, a novel approach to dual-target glioblastoma vasculature and tumor cells was investigated. Liposomes (124 nm) were conjugated with a αvβ3 ligand, cyclic arginine-glycine-aspartic acid-tyrosine-cysteine peptide (c(RGDyC)-LP) (1% molar ratio) through thiol-maleimide coupling. Expression of αvβ3 in glioblastoma cells (U87) and human umbilical vein endothelial cells (HUVEC), representing tumor angiogenesis, was determined using Western Blotting with other cells as references. The results showed that both U87 and HUVEC had stronger expression of αvβ3 than other cell types, and the degree of cellular uptake of c(RGDyC)-LP correlated with the αvβ3-expression levels of the cells. In contrast, control liposomes without c(RGDyC) showed little cellular uptake, regardless of cell type. In an in vitro boron neutron capture therapy study, the c(RGDyC)-LP containing sodium borocaptate generated more rapid and significant lethal effects to both U87 and HUVEC than the control liposomes and drug solution. Interestingly, neutron irradiated U87 and HUVEC showed different types of subsequent cell death. In conclusion, this study has demonstrated the potential of a new dual-targeting strategy using c(RGDyC)-LP to improve boron neutron capture therapy for glioblastoma.

  12. Cyclic-RGDyC functionalized liposomes for dual-targeting of tumor vasculature and cancer cells in glioblastoma: An in vitro boron neutron capture therapy study

    PubMed Central

    Kang, Weirong; Svirskis, Darren; Sarojini, Vijayalekshmi; McGregor, Ailsa L.; Bevitt, Joseph; Wu, Zimei

    2017-01-01

    The efficacy of boron neutron capture therapy depends on the selective delivery of 10B to the target. Integrins αvβ3 are transmembrane receptors over-expressed in both glioblastoma cells and its neovasculature. In this study, a novel approach to dual-target glioblastoma vasculature and tumor cells was investigated. Liposomes (124 nm) were conjugated with a αvβ3 ligand, cyclic arginine-glycine-aspartic acid-tyrosine-cysteine peptide (c(RGDyC)-LP) (1% molar ratio) through thiol-maleimide coupling. Expression of αvβ3 in glioblastoma cells (U87) and human umbilical vein endothelial cells (HUVEC), representing tumor angiogenesis, was determined using Western Blotting with other cells as references. The results showed that both U87 and HUVEC had stronger expression of αvβ3 than other cell types, and the degree of cellular uptake of c(RGDyC)-LP correlated with the αvβ3-expression levels of the cells. In contrast, control liposomes without c(RGDyC) showed little cellular uptake, regardless of cell type. In an in vitro boron neutron capture therapy study, the c(RGDyC)-LP containing sodium borocaptate generated more rapid and significant lethal effects to both U87 and HUVEC than the control liposomes and drug solution. Interestingly, neutron irradiated U87 and HUVEC showed different types of subsequent cell death. In conclusion, this study has demonstrated the potential of a new dual-targeting strategy using c(RGDyC)-LP to improve boron neutron capture therapy for glioblastoma. PMID:28402271

  13. Boron neutron capture therapy of malignant brain tumors at the Brookhaven Medical Research Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joel, D.D.; Coderre, J.A.; Chanana, A.D.

    1996-12-31

    Boron neutron capture therapy (BNCT) is a bimodal form of radiation therapy for cancer. The first component of this treatment is the preferential localization of the stable isotope {sup 10}B in tumor cells by targeting with boronated compounds. The tumor and surrounding tissue is then irradiated with a neutron beam resulting in thermal neutron/{sup 10}B reactions ({sup 10}B(n,{alpha}){sup 7}Li) resulting in the production of localized high LET radiation from alpha and {sup 7}Li particles. These products of the neutron capture reaction are very damaging to cells, but of short range so that the majority of the ionizing energy released ismore » microscopically confined to the vicinity of the boron-containing compound. In principal it should be possible with BNCT to selectively destroy small nests or even single cancer cells located within normal tissue. It follows that the major improvements in this form of radiation therapy are going to come largely from the development of boron compounds with greater tumor selectivity, although there will certainly be advances made in neutron beam quality as well as the possible development of alternative sources of neutron beams, particularly accelerator-based epithermal neutron beams.« less

  14. The Perspectives of the Boron Neutron Capture Therapy-Clinical Applications Research and Development in Saudi Arabia

    NASA Astrophysics Data System (ADS)

    Badhrees, I.; Alrumayan, F.; Mahube, F.

    Boron Neutron Capture Therapy (BNCT) is a binary form of experimental radiotherapy which is based on the administration of a drug able to concentrate the isotopes in a tumor cell that later are irradiated with a neutron beam. Even though the first evidence of the success of this treatment dates back many years ago, BNCT showed successful treatment results in malignant melanoma, and Glioblastoma. In order for BNCT to be successful, a sufficient amount of Boron (10B) must be selectively delivered to the tumor cell, and then irradiated by neutrons of sufficient enough. The CS-30 cyclotron at King Faisal Specialist Hospital & Research Center is a positive-ion machine capable of accelerating protons at 26MeV, and other isotopes as well. Although the peak beam intensity from the CS-30 is low, the key to success of using it for the BNCT is by using a high average beam current at low energy. This work is aimed at testing the capability of the CS-30 Cyclotron to produce a low-energy neutron beam to be used to activate the Boron atoms injected into the tumor cell, through simulation of a compatible moderator. We are also planning to measure the overall dosimetry of the energy dose as well as that for the boron in the tumor cell.

  15. Demonstration of a high-intensity neutron source based on a liquid-lithium target for Accelerator based Boron Neutron Capture Therapy.

    PubMed

    Halfon, S; Arenshtam, A; Kijel, D; Paul, M; Weissman, L; Berkovits, D; Eliyahu, I; Feinberg, G; Kreisel, A; Mardor, I; Shimel, G; Shor, A; Silverman, I; Tessler, M

    2015-12-01

    A free surface liquid-lithium jet target is operating routinely at Soreq Applied Research Accelerator Facility (SARAF), bombarded with a ~1.91 MeV, ~1.2 mA continuous-wave narrow proton beam. The experiments demonstrate the liquid lithium target (LiLiT) capability to constitute an intense source of epithermal neutrons, for Accelerator based Boron Neutron Capture Therapy (BNCT). The target dissipates extremely high ion beam power densities (>3 kW/cm(2), >0.5 MW/cm(3)) for long periods of time, while maintaining stable conditions and localized residual activity. LiLiT generates ~3×10(10) n/s, which is more than one order of magnitude larger than conventional (7)Li(p,n)-based near threshold neutron sources. A shield and moderator assembly for BNCT, with LiLiT irradiated with protons at 1.91 MeV, was designed based on Monte Carlo (MCNP) simulations of BNCT-doses produced in a phantom. According to these simulations it was found that a ~15 mA near threshold proton current will apply the therapeutic doses in ~1h treatment duration. According to our present results, such high current beams can be dissipated in a liquid-lithium target, hence the target design is readily applicable for accelerator-based BNCT. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Manual vs. automatic capture management in implantable cardioverter defibrillators and cardiac resynchronization therapy defibrillators.

    PubMed

    Murgatroyd, Francis D; Helmling, Erhard; Lemke, Bernd; Eber, Bernd; Mewis, Christian; van der Meer-Hensgens, Judith; Chang, Yanping; Khalameizer, Vladimir; Katz, Amos

    2010-06-01

    The Secura ICD and Consulta CRT-D are the first defibrillators to have automatic right atrial (RA), right ventricular (RV), and left ventricular (LV) capture management (CM). Complete CM was evaluated in an implantable cardioverter defibrillator (ICD) population. Two prospective clinical studies were conducted in 28 centres in Europe and Israel. Automatic CM data were compared with manual threshold measurements, the CM applicability was determined, and adjustments to pacing outputs were analysed. In total, 160 patients [age 64.6 +/- 10.4 years, 77% male, 80 ICD and 80 cardiac resynchronization therapy defibrillator (CRT-D)] were included. The differences between automatic and manual measurements were 2.5 V) due to raised RA threshold in seven (4.4%), high RV threshold in nine (5.6%), and high LV threshold in three patients (3.8%). All high threshold detections and all automatic modulations of pacing output were adjudicated appropriate. Complete CM adjusts pacing output appropriately, permitting a reduction in office visits while it may maximize device longevity. The study was registered at ClinicalTrials.gov identifiers: NCT00526227 and NCT00526162.

  17. Intracellular delivery and passive tumor targeting of a self-assembled nanogel containing carborane clusters for boron neutron capture therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kawasaki, Riku; JST-ERATO, Japan Science and Technology Agency; Sasaki, Yoshihiro

    Boron neutron capture therapy, based on the release of thermal neutron irradiation from boron, is a targeted radiation therapy for cancer. Targeted and sufficient accumulation of boron in tumor cells to achieve cytotoxic efficacy and reduce off-target effects remains a challenge. Carborane has been investigated for use as a delivery agent in boron neutron capture therapy because of its high boron content and chemical stability; however, it is cytotoxic, making safe delivery difficult. The aim of this study was to investigate the potential of carborane-bearing pullulan nanogels to safely and effectively deliver boron to tumor cells in vitro and in vivo and,more » consequently, assess their potential as a boron neutron capture therapeutic. Murine fibrosarcoma cells (CMS5a) were used for in vitro investigations of nanogel cytotoxicity, cell uptake. A mouse fibrosarcoma xenograft model was used to investigate the bio-distribution of nanogels after intravenous administration. The nanogels produced no apparent cytotoxicity and underwent cell uptake in CMS5a cells after a 24 h incubation at up to 2000 μg/mL and 400 μg/mL, respectively. The internalized nanogels were localized around the nuclear membrane. The nanogels were administered intravenously to mice bearing fibrosarcoma xenografts. Nanogel tumor localization likely occurred through the enhanced permeation and retention effect. The nanogels successfully reduced the cytotoxicity of carborane, were internalized into tumor cells, acted as a dual-delivery therapeutic and accumulated in tumors in vivo. Consequently, they demonstrate significant potential as a boron neutron capture therapeutic. - Highlights: • A carborane-bearing pullulan nanogel is developed as a boron delivery agent. • The nanogels are cell-friendly and show effective cell uptake for drug delivery. • The nanogels show passive tumor targeting by enhanced permeation and retention.« less

  18. The Effect of Deep Brain Stimulation Therapy on Fear-Related Capture of Attention in Parkinson's Disease and Essential Tremor: A Comparison to Healthy Individuals.

    PubMed

    Camalier, Corrie R; McHugo, Maureen; Zald, David H; Neimat, Joseph S

    2018-01-01

    In addition to motor symptoms, Parkinson's disease (PD) involves significant non-motor sequelae, including disruptions in cognitive and emotional processing. Fear recognition appears to be affected both by the course of the disease and by a common interventional therapy, deep brain stimulation of the subthalamic nucleus (STN-DBS). Here, we examined if these effects extend to other aspects of emotional processing, such as attentional capture by negative emotional stimuli. Performance on an emotional attentional blink (EAB) paradigm, a common paradigm used to study emotional capture of attention, was examined in a cohort of individuals with PD, both on and off STN-DBS therapy (n=20). To contrast effects of healthy aging and other movement disorder and DBS targets, we also examined performance in a healthy elderly (n=20) and young (n=18) sample on the same task, and a sample diagnosed with Essential Tremor (ET) undergoing therapeutic deep brain stimulation of the ventral-intermediate nucleus (VIM-DBS, n=18). All four groups showed a robust attentional capture of emotional stimuli, irrespective of aging processes, movement disorder diagnosis, or stimulation. PD patients on average had overall worse performance, but this decrement in performance was not related to the emotional capture of attention. PD patients exhibited a robust EAB, indicating that the ability of emotion to direct attention remains intact in PD. Congruent with other recent data, these findings suggest that fear recognition deficits in PD may instead reflect a highly specific problem in recognition, rather than a general deficit in emotional processing of fearful stimuli.

  19. Metalloporphyrins and their uses as radiosensitizers for radiation therapy

    DOEpatents

    Miura, Michiko; Slatkin, Daniel N.

    2004-07-06

    The present invention covers radiosensitizers containing as an active ingredient halogenated derivatives of boronated porphyrins containing multiple carborane cages having the structure ##STR1## which selectively accumulate in neoplastic tissue within the irradiation volume and thus can be used in cancer therapies including, but not limited to, boron neutron--capture therapy and photodynamic therapy. The present invention also covers methods for using these radiosensitizers in tumor imaging and cancer treatment.

  20. System and method for delivery of neutron beams for medical therapy

    DOEpatents

    Nigg, D.W.; Wemple, C.A.

    1999-07-06

    A neutron delivery system that provides improved capability for tumor control during medical therapy is disclosed. The system creates a unique neutron beam that has a bimodal or multi-modal energy spectrum. This unique neutron beam can be used for fast-neutron therapy, boron neutron capture therapy (BNCT), or both. The invention includes both an apparatus and a method for accomplishing the purposes of the invention. 5 figs.

  1. Potential of boron neutron capture therapy (BNCT) for malignant peripheral nerve sheath tumors (MPNST).

    PubMed

    Fujimoto, Takuya; Andoh, Tooru; Sudo, Tamotsu; Fujita, Ikuo; Fukase, Naomasa; Takeuchi, Tamotsu; Sonobe, Hiroshi; Inoue, Masayoshi; Hirose, Tkanori; Sakuma, Toshiko; Moritake, Hiroshi; Sugimoto, Tohru; Kawamoto, Teruya; Fukumori, Yoshinobu; Yamamoto, Satomi; Atagi, Shinji; Sakurai, Yoshinori; Kurosaka, Masahiro; Ono, Koji; Ichikawa, Hideki; Suzuki, Minoru

    2015-12-01

    Malignant peripheral nerve sheath tumors (MPNST) are relatively rare neoplasms with poor prognosis. At present there is no effective treatment for MPNST other than surgical resection. Nonetheless, the anti-tumor effect of boron neutron capture therapy (BNCT) was recently demonstrated in two patients with MPNST. Subsequently, tumor-bearing nude mice subcutaneously transplanted with a human MPNST cell line were injected with p-borono-L-phenylalanine (L-BPA) and subjected to BNCT. Pathological studies then revealed that the MPNST cells were selectively destroyed by BNCT. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Correlation between radiation dose and histopathological findings in patients with gliblastoma treated with boron neutron capture therapy (BNCT).

    PubMed

    Kageji, T; Mizobuchi, Y; Nagahiro, S; Nakagawa, Y; Kumada, H

    2014-06-01

    The purpose of this study was to clarify the correlation between the radiation dose and histopathological findings in patients with glioblastoma multiforme (GBM) treated with boron neutron capture therapy (BNCT). Histopathological studies were performed on specimens from 8 patients, 3 had undergone salvage surgery and 5 were autopsied. For histopathological cure of GBM at the primary site, the optimal minimal dose to the gross tumor volume (GTV) and the clinical target volume (CTV) were 68Gy(w) and 44Gy(w), respectively. Copyright © 2014. Published by Elsevier Ltd.

  3. Boron neutron capture therapy (BNCT) for newly-diagnosed glioblastoma: comparison of clinical results obtained with BNCT and conventional treatment.

    PubMed

    Kageji, Teruyoshi; Nagahiro, Shinji; Mizobuchi, Yoshifumi; Matsuzaki, Kazuhito; Nakagawa, Yoshinobu; Kumada, Hiroaki

    2014-01-01

    The purpose of this study was to evaluate the clinical outcome of boron neutron capture therapy (BNCT) and conventional treatment in patients with newly diagnosed glioblastoma. Since 1998 we treated 23 newly-diagosed GBM patients with BNCT without any additional chemotherapy. Their median survival time was 19.5 months; the 2-, 3-, and 5-year survival rates were 31.8%, 22.7%, and 9.1%, respectively. The clinical results of BNCT in patients with GBM are similar to those of recent conventional treatments based on radiotherapy with concomitant and adjuvant temozolomide.

  4. NEUTRON CAPTURE THERAPY OF A CEREBELLAR HEMANGIOSARCOMA AFTER SURGICAL AND RADIATION TREATMENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farr, L.E.; Yamamoto, L.Y.

    1961-10-01

    A patient with a hioghly maliognant vascular sarcoma of the cerebellum was treated hv neutron capture therapy. Almost complete elimination of the neoplasm was attained. Other than the skin, normal tissues about and within the neoplastioc mass did not appear to be adversely affected. An unusual and unexpected bulbar conjunctivitis was observed as a complication. The degree of control attained by this experimental procedure was more positive than that previously attained by surgery or conventional x-ray therapy. This is the first attempt to control an intracranial tumor other than glioblastoma multiforme by this procedure. The patient is noteworthy for themore » extreme retention of carbon dioxiode, 60 milli-equivalents per liter in the blood, apparently resulting from functional disturbances of the respiratory center. (auth)« less

  5. Evaluation of BPA uptake in clear cell sarcoma (CCS) in vitro and development of an in vivo model of CCS for BNCT studies.

    PubMed

    Fujimoto, T; Andoh, T; Sudo, T; Fujita, I; Imabori, M; Moritake, H; Sugimoto, T; Sakuma, Y; Takeuchi, T; Sonobe, H; Epstein, Alan L; Akisue, T; Kirihata, M; Kurosaka, M; Fukumori, Y; Ichikawa, H

    2011-12-01

    Clear cell sarcoma (CCS), a rare malignant tumor with a predilection for young adults, is of poor prognosis. Recently however, boron neutron capture therapy (BNCT) with the use of p-borono-L-phenylalanine (BPA) for malignant melanoma has provided good results. CCS also produces melanin; therefore, the uptake of BPA is the key to the application of BNCT to CCS. We describe, for the first time, the high accumulation of boron in CCS and the CCS tumor-bearing animal model generated for BNCT studies. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Selective boron delivery by intra-arterial injection of BSH-WOW emulsion in hepatic cancer model for neutron capture therapy

    PubMed Central

    Dewi, Novriana; Higashi, Syushi; Ikushima, Ichiro; Seguchi, Koji; Mizumachi, Ryoji; Murata, Yuji; Morishita, Yasuyuki; Shinohara, Atsuko; Mikado, Shoji; Yasuda, Nakahiro; Fujihara, Mitsuteru; Sakurai, Yuriko; Mouri, Kikue; Yanagawa, Masashi; Iizuka, Tomoya; Suzuki, Minoru; Sakurai, Yoshinori; Masunaga, Shin-ichiro; Tanaka, Hiroki; Matsukawa, Takehisa; Yokoyama, Kazuhito; Fujino, Takashi; Ogura, Koichi; Nonaka, Yasumasa; Sugiyama, Hirotaka; Kajiyama, Tetsuya; Yui, Sho; Nishimura, Ryohei; Ono, Koji; Takamoto, Sinichi; Nakajima, Jun; Ono, Minoru; Eriguchi, Masazumi; Hasumi, Kenichiro; Takahashi, Hiroyuki

    2017-01-01

    Objective: Boron neutron-capture therapy (BNCT) has been used to inhibit the growth of various types of cancers. In this study, we developed a 10BSH-entrapped water-in-oil-in-water (WOW) emulsion, evaluated it as a selective boron carrier for the possible application of BNCT in hepatocellular carcinoma treatment. Methods: We prepared the 10BSH-entrapped WOW emulsion using double emulsification technique and then evaluated the delivery efficacy by performing biodistribution experiment on VX-2 rabbit hepatic tumour model with comparison to iodized poppy-seed oil mix conventional emulsion. Neutron irradiation was carried out at Kyoto University Research Reactor with an average thermal neutron fluence of 5 × 1012 n cm−2. Morphological and pathological analyses were performed on Day 14 after neutron irradiation. Results: Biodistribution results have revealed that 10B atoms delivery with WOW emulsion was superior compared with those using iodized poppy-seed oil conventional emulsion. There was no dissemination in abdomen or lung metastasis observed after neutron irradiation in the groups treated with 10BSH-entrapped WOW emulsion, whereas many tumour nodules were recognized in the liver, abdominal cavity, peritoneum and bilateral lobes of the lung in the non-injected group. Conclusion: Tumour growth suppression and cancer-cell-killing effect was observed from the morphological and pathological analyses of the 10BSH-entrapped WOW emulsion-injected group, indicating its feasibility to be applied as a novel intra-arterial boron carrier for BNCT. Advances in knowledge: The results of the current study have shown that entrapped 10BSH has the potential to increase the range of therapies available for hepatocellular carcinoma which is considered to be one of the most difficult tumours to cure. PMID:28406315

  7. Chemoresponsive Colloidosomes via Ag⁺ Soldering of Surface-Assembled Nanoparticle Monolayers.

    PubMed

    Liu, Miao; Tian, Qian; Li, Yulin; You, Bo; Xu, An; Deng, Zhaoxiang

    2015-04-28

    Colloidosomes with a hollow interior and a porous plasmonic shell are highly desired for many applications including nanoreactors, surface-enhanced Raman scattering (SERS), photothermal therapy, and controlled drug release. We herein report a silica nanosphere-templated electrostatic self-assembly in conjunction with a newly developed Ag(+) soldering to fabricate gold colloidosomes toward multifunctionality and stimuli-responsibility. The gold colloidosomes are capable of capturing a nanosized object and releasing it via structural dissociation upon responding to a biochemical input (GSH, glutathione) at a concentration close to its cellular level. In addition, the colloidosomes have a tunable nanoporous shell composed of strongly coupled gold nanoparticles, which exhibit broadened near-infrared plasmon resonance. These features along with the simplicity and high tunability of the fabrication process make the gold colloidosomes quite promising for applications in a chemical or cellular environment.

  8. Metalloporphyrins and their uses as imageable tumor-targeting agents for radiation therapy

    DOEpatents

    Miura, Michiko; Slatkin, Daniel N.

    2003-05-20

    The present invention covers halogenated derivatives of boronated porphyrins containing multiple carborane cages having the formula ##STR1## which selectively accumulate in neoplastic tissue within the irradiation volume and thus can be used in cancer therapies including, but not limited to, boron neutron- capture therapy and photodynamic therapy. The present invention also covers methods for using these halogenated derivatives of boronated porphyrins in tumor imaging and cancer treatment.

  9. Use of novel metalloporphyrins as imageable tumor-targeting agents for radiation therapy

    DOEpatents

    Miura, Michiko; Slatkin, Daniel N.

    2005-10-04

    The present invention covers halogenated derivatives of boronated phorphyrins containing multiple carborane cages having the formula ##STR1## which selectively accumulate in neoplastic tissue within the irradiation volume and thus can be used in cancer therapies including, but not limited to, boron neutron-capture therapy and photodynamic therapy. The present invention also covers methods for using these halogenated derivatives of boronated porphyrins in tumor imaging and cancer treatment.

  10. A Microfluidic Chip Integrated with Hyaluronic Acid-Functionalized Electrospun Chitosan Nanofibers for Specific Capture and Nondestructive Release of CD44-Overexpressing Circulating Tumor Cells.

    PubMed

    Wang, Mengyuan; Xiao, Yunchao; Lin, Lizhou; Zhu, Xiaoyue; Du, Lianfang; Shi, Xiangyang

    2018-04-18

    Detection of circulating tumor cells (CTCs) in peripheral blood is of paramount significance for early-stage cancer diagnosis, estimation of cancer development, and individualized cancer therapy. Herein, we report the development of hyaluronic acid (HA)-functionalized electrospun chitosan nanofiber (CNF)-integrated microfludic platform for highly specific capture and nondestructive release of CTCs. First, electrospun CNFs were formed and modified with zwitterion of carboxyl betaine acrylamide (CBAA) via Michael addition reaction and then targeting ligand HA through a disulfide bond. We show that the formed nanofibers still maintain the smooth fibrous morphology after sequential surface modifications, have a good hemocompatibility, and exhibit an excellent antifouling property due to the CBAA modification. After being embedded within a microfluidic chip, the fibrous mat can capture cancer cells (A549, a human lung cancer cell line) with an efficiency of 91% at a flow rate of 1.0 mL/h. Additionally, intact release of cancer cells is able to be achieved after treatment with glutathione for 40 min to have a release efficiency of 90%. Clinical applications show that 9 of 10 nonsmall-cell lung cancer patients and 5 of 5 breast cancer patients are diagnosed to have CTCs (1 to 18 CTCs per mL of blood). Our results suggest that the developed microfluidic system integrated with functionalized CNF mats may be employed for effective CTCs capture for clinical diagnosis of cancer.

  11. Application of neutron capture autoradiography to Boron Delivery seeking techniques for selective accumulation of boron compounds to tumor with intra-arterial administration of boron entrapped water-in-oil-in-water emulsion

    NASA Astrophysics Data System (ADS)

    Mikado, S.; Yanagie, H.; Yasuda, N.; Higashi, S.; Ikushima, I.; Mizumachi, R.; Murata, Y.; Morishita, Y.; Nishimura, R.; Shinohara, A.; Ogura, K.; Sugiyama, H.; Iikura, H.; Ando, H.; Ishimoto, M.; Takamoto, S.; Eriguchi, M.; Takahashi, H.; Kimura, M.

    2009-06-01

    It is necessary to accumulate the 10B atoms selectively to the tumor cells for effective Boron Neutron Capture Therapy (BNCT). In order to achieve an accurate measurement of 10B accumulations in the biological samples, we employed a technique of neutron capture autoradiography (NCAR) of sliced samples of tumor tissues using CR-39 plastic track detectors. The CR-39 track detectors attached with the biological samples were exposed to thermal neutrons in the thermal column of the JRR3 of Japan Atomic Energy Agency (JAEA). We obtained quantitative NCAR images of the samples for VX-2 tumor in rabbit liver after injection of 10BSH entrapped water-in-oil-in-water (WOW) emulsion by intra-arterial injection via proper hepatic artery. The 10B accumulations and distributions in VX-2 tumor and normal liver of rabbit were investigated by means of alpha-track density measurements. In this study, we showed the selective accumulation of 10B atoms in the VX-2 tumor by intra-arterial injection of 10B entrapped WOW emulsion until 3 days after injection by using digitized NCAR images (i.e. alpha-track mapping).

  12. Capturing and missing the patient's story through outcome measures: A thematic comparison of patient-generated items in PSYCHLOPS with CORE-OM and PHQ-9.

    PubMed

    Sales, Célia Md; Neves, Inês Td; Alves, Paula G; Ashworth, Mark

    2017-11-22

    There is increasing interest in individualized patient-reported outcome measures (I-PROMS), where patients themselves indicate the specific problems they want to address in therapy and these problems are used as items within the outcome measurement tool. This paper examined the extent to which 279 items reported in an I-PROM (PSYCHLOPS) added qualitative information which was not captured by two well-established outcome measures (CORE-OM and PHQ-9). Comparison of items was only conducted for patients scoring above the "caseness" threshold on the standardized measures. 107 patients were participating in therapy within addiction and general psychiatric clinical settings. Almost every patient (95%) reported at least one item whose content was not covered by PHQ-9, and 71% reported at least one item not covered by CORE-OM. Results demonstrate the relevance of individualized outcome assessment for capturing data describing the issues of greatest concern to patients, as nomothetic measures do not always seem to capture the whole story. © 2017 The Authors Health Expectations Published by John Wiley & Sons Ltd.

  13. Developments in capture-γ libraries for nonproliferation applications

    NASA Astrophysics Data System (ADS)

    Hurst, A. M.; Firestone, R. B.; Sleaford, B. W.; Bleuel, D. L.; Basunia, M. S.; Bečvář, F.; Belgya, T.; Bernstein, L. A.; Carroll, J. J.; Detwiler, B.; Escher, J. E.; Genreith, C.; Goldblum, B. L.; Krtička, M.; Lerch, A. G.; Matters, D. A.; McClory, J. W.; McHale, S. R.; Révay, Zs.; Szentmiklosi, L.; Turkoglu, D.; Ureche, A.; Vujic, J.

    2017-09-01

    The neutron-capture reaction is fundamental for identifying and analyzing the γ-ray spectrum from an unknown assembly because it provides unambiguous information on the neutron-absorbing isotopes. Nondestructive-assay applications may exploit this phenomenon passively, for example, in the presence of spontaneous-fission neutrons, or actively where an external neutron source is used as a probe. There are known gaps in the Evaluated Nuclear Data File libraries corresponding to neutron-capture γ-ray data that otherwise limit transport-modeling applications. In this work, we describe how new thermal neutron-capture data are being used to improve information in the neutron-data libraries for isotopes relevant to nonproliferation applications. We address this problem by providing new experimentally-deduced partial and total neutron-capture reaction cross sections and then evaluate these data by comparison with statistical-model calculations.

  14. A novel adaptive mixed reality system for stroke rehabilitation: principles, proof of concept, and preliminary application in 2 patients.

    PubMed

    Chen, Yinpeng; Duff, Margaret; Lehrer, Nicole; Liu, Sheng-Min; Blake, Paul; Wolf, Steven L; Sundaram, Hari; Rikakis, Thanassis

    2011-01-01

    This article presents the principles of an adaptive mixed reality rehabilitation (AMRR) system, as well as the training process and results from 2 stroke survivors who received AMRR therapy, to illustrate how the system can be used in the clinic. The AMRR system integrates traditional rehabilitation practices with state-of-the-art computational and motion capture technologies to create an engaging environment to train reaching movements. The system provides real-time, intuitive, and integrated audio and visual feedback (based on detailed kinematic data) representative of goal accomplishment, activity performance, and body function during a reaching task. The AMRR system also provides a quantitative kinematic evaluation that measures the deviation of the stroke survivor's movement from an idealized, unimpaired movement. The therapist, using the quantitative measure and knowledge and observations, can adapt the feedback and physical environment of the AMRR system throughout therapy to address each participant's individual impairments and progress. Individualized training plans, kinematic improvements measured over the entire therapy period, and the changes in relevant clinical scales and kinematic movement attributes before and after the month-long therapy are presented for 2 participants. The substantial improvements made by both participants after AMRR therapy demonstrate that this system has the potential to considerably enhance the recovery of stroke survivors with varying impairments for both kinematic improvements and functional ability.

  15. SU-E-T-435: Development and Commissioning of a Complete System for In-Vivo Dosimetry and Range Verification in Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Samuel, D; Testa, M; Park, Y

    Purpose: In-vivo dose and beam range verification in proton therapy could play significant roles in proton treatment validation and improvements. Invivo beam range verification, in particular, could enable new treatment techniques one of which, for example, could be the use of anterior fields for prostate treatment instead of opposed lateral fields as in current practice. We have developed and commissioned an integrated system with hardware, software and workflow protocols, to provide a complete solution, simultaneously for both in-vivo dosimetry and range verification for proton therapy. Methods: The system uses a matrix of diodes, up to 12 in total, but separablemore » into three groups for flexibility in application. A special amplifier was developed to capture extremely small signals from very low proton beam current. The software was developed within iMagX, a general platform for image processing in radiation therapy applications. The range determination exploits the inherent relationship between the internal range modulation clock of the proton therapy system and the radiological depth at the point of measurement. The commissioning of the system, for in-vivo dosimetry and for range verification was separately conducted using anthropomorphic phantom. EBT films and TLDs were used for dose comparisons and range scan of the beam distal fall-off was used as ground truth for range verification. Results: For in-vivo dose measurement, the results were in agreement with TLD and EBT films and were within 3% from treatment planning calculations. For range verification, a precision of 0.5mm is achieved in homogeneous phantoms, and a precision of 2mm for anthropomorphic pelvic phantom, except at points with significant range mixing. Conclusion: We completed the commissioning of our system for in-vivo dosimetry and range verification in proton therapy. The results suggest that the system is ready for clinical trials on patient.« less

  16. Synthesis and biological evaluation of new boron-containing chlorin derivatives as agents for both photodynamic therapy and boron neutron capture therapy of cancer.

    PubMed

    Asano, Ryuji; Nagami, Amon; Fukumoto, Yuki; Miura, Kaori; Yazama, Futoshi; Ito, Hideyuki; Sakata, Isao; Tai, Akihiro

    2014-03-01

    New boron-containing chlorin derivatives 9 and 13 as agents for both photodynamic therapy (PDT) and boron neutron capture therapy (BNCT) of cancer were synthesized from photoprotoporphyrin IX dimethyl ester (2) and L-4-boronophenylalanine-related compounds. The in vivo biodistribution and clearance of 9 and 13 were investigated in tumor-bearing mice. The time to maximum accumulation of compound 13 in tumor tissue was one-fourth of that of compound 9, and compound 13 showed rapid clearance from normal tissues within 24h after injection. The in vivo therapeutic efficacy of PDT using 13 was evaluated by measuring tumor growth rates in tumor-bearing mice with 660 nm light-emitting diode irradiation at 3h after injection of 13. Tumor growth was significantly inhibited by PDT using 13. These results suggested that 13 might be a good candidate for both PDT and BNCT of cancer. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Driving personalized medicine: capturing maximum net present value and optimal return on investment.

    PubMed

    Roth, Mollie; Keeling, Peter; Smart, Dave

    2010-01-01

    In order for personalized medicine to meet its potential future promise, a closer focus on the work being carried out today and the foundation it will provide for that future is imperative. While big picture perspectives of this still nascent shift in the drug-development process are important, it is more important that today's work on the first wave of targeted therapies is used to build specific benchmarking and financial models against which further such therapies may be more effectively developed. Today's drug-development teams need a robust tool to identify the exact drivers that will ensure the successful launch and rapid adoption of targeted therapies, and financial metrics to determine the appropriate resource levels to power those drivers. This special report will describe one such benchmarking and financial model that is specifically designed for the personalized medicine field and will explain how the use of this or similar models can help to capture the maximum net present value of targeted therapies and help to realize optimal return on investment.

  18. Final Stage in the Design of a Boron Neutron Capture Therapy facility at CEADEN, Cuba

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cabal, F. Padilla; Martin, G.

    A neutron beam simulation study is carried out to determine the most suitable neutron energy for treatment of shallow and deep-seated brain tumors in the context of Boron Neutron Capture Therapy (BNCT). Two figures-of-merit, the therapeutic gain and the neutron fluence are utilized as beam assessment parameters. An irradiation cavity is used instead of a parallel beam port for the therapy. Calculations are performed using the MCNP5 code. After the optimization of our beam-shaper a study of the dose distribution in the head, neck, tyroids, lungs and upper and middle spine had been made. The therapeutic gain is increased whilemore » the current required for one hour treatment is decreased in comparison with the trading prototypes of NG used for BNCT.« less

  19. Biological activity of N(4)-boronated derivatives of 2'-deoxycytidine, potential agents for boron-neutron capture therapy.

    PubMed

    Nizioł, Joanna; Uram, Łukasz; Szuster, Magdalena; Sekuła, Justyna; Ruman, Tomasz

    2015-10-01

    Boron-neutron capture therapy (BNCT) is a binary anticancer therapy that requires boron compound for nuclear reaction during which high energy alpha particles and lithium nuclei are formed. Unnatural, boron-containing nucleoside with hydrophobic pinacol moiety was investigated as a potential BNCT boron delivery agent. Biological properties of this compound are presented for the first time and prove that boron nucleoside has low cytotoxicity and that observed apoptotic effects suggest alteration of important functions of cancer cells. Mass spectrometry analysis of DNA from cancer cells proved that boron nucleoside is inserted into nucleic acids as a functional nucleotide derivative. NMR studies present very high degree of similarity of natural dG-dC base pair with dG-boron nucleoside system. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Development of high intensity ion sources for a Tandem-Electrostatic-Quadrupole facility for Accelerator-Based Boron Neutron Capture Therapy.

    PubMed

    Bergueiro, J; Igarzabal, M; Sandin, J C Suarez; Somacal, H R; Vento, V Thatar; Huck, H; Valda, A A; Repetto, M; Kreiner, A J

    2011-12-01

    Several ion sources have been developed and an ion source test stand has been mounted for the first stage of a Tandem-Electrostatic-Quadrupole facility For Accelerator-Based Boron Neutron Capture Therapy. A first source, designed, fabricated and tested is a dual chamber, filament driven and magnetically compressed volume plasma proton ion source. A 4 mA beam has been accelerated and transported into the suppressed Faraday cup. Extensive simulations of the sources have been performed using both 2D and 3D self-consistent codes. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. Boron neutron capture therapy (BNCT) as a new approach for clear cell sarcoma (CCS) treatment: Trial using a lung metastasis model of CCS.

    PubMed

    Andoh, Tooru; Fujimoto, Takuya; Suzuki, Minoru; Sudo, Tamotsu; Sakurai, Yoshinori; Tanaka, Hiroki; Fujita, Ikuo; Fukase, Naomasa; Moritake, Hiroshi; Sugimoto, Tohru; Sakuma, Toshiko; Sasai, Hiroshi; Kawamoto, Teruya; Kirihata, Mitsunori; Fukumori, Yoshinobu; Akisue, Toshihiro; Ono, Koji; Ichikawa, Hideki

    2015-12-01

    Clear cell sarcoma (CCS) is a rare malignant tumor with a poor prognosis. In the present study, we established a lung metastasis animal model of CCS and investigated the therapeutic effect of boron neutron capture therapy (BNCT) using p-borono-L-phenylalanine (L-BPA). Biodistribution data revealed tumor-selective accumulation of (10)B. Unlike conventional gamma-ray irradiation, BNCT significantly suppressed tumor growth without damaging normal tissues, suggesting that it may be a potential new therapeutic option to treat CCS lung metastases. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Boron neutron capture therapy for clear cell sarcoma (CCS): biodistribution study of p-borono-L-phenylalanine in CCS-bearing animal models.

    PubMed

    Andoh, T; Fujimoto, T; Sudo, T; Fujita, I; Imabori, M; Moritake, H; Sugimoto, T; Sakuma, Y; Takeuchi, T; Kawabata, S; Kirihata, M; Akisue, T; Yayama, K; Kurosaka, M; Miyatake, S; Fukumori, Y; Ichikawa, H

    2011-12-01

    Clear cell sarcoma (CCS) is a rare melanocytic malignant tumor with a poor prognosis. Our previous study demonstrated that in vitro cultured CCS cells have the ability to highly uptake l-BPA and thus boron neutron capture therapy could be a new option for CCS treatment. This paper proved that a remarkably high accumulation of (10)B (45-74 ppm) in tumor was obtained even in a CCS-bearing animal with a well-controlled biodistribution followed by intravenous administration of L-BPA-fructose complex (500 mg BPA/kg). Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Experiments to increase the parameters of the vacuum insulation tandem accelerator for boron neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Kasatov, D. A.; Kolesnikov, J. A.; Koshkarev, A. M.; Kuznetsov, A. S.; Makarov, A. N.; Sokolova, E. O.; Sorokin, I. N.; Sycheva, T. V.; Taskaev, S. Yu.; Shchudlo, I. M.

    2016-12-01

    An epithermal neutron source that is based on a vacuum insulation tandem accelerator (VITA) and lithium target was created in the Budker Institute of Nuclear Physics for the development of boron neutron capture therapy (BNCT). A stationary proton beam with 2 MeV energy and 1.6 mA current has been obtained. To carry out BNCT, it is necessary to increase the beam parameters up to 2.3 MeV and 3 mA. Ways to increase the parameters of the proton beam have been proposed and discussed in this paper. The results of the experiments are presented.

  4. Molecular Medicine: Synthesis and In Vivo Detection of Agents for use in Boron Neutron Capture Therapy. Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kabalka, G. W.

    2005-06-28

    The primary objective of the project was the development of in vivo methods for the detection and evaluation of tumors in humans. The project was focused on utilizing positron emission tomography (PET) to monitor the distribution and pharamacokinetics of a current boron neutron capture therapy (BNCT) agent, p-boronophenylalanine (BPA) by labeling it with a fluorine-18, a positron emitting isotope. The PET data was then used to develop enhanced treatment planning protocols. The study also involved the synthesis of new tumor selective BNCTagents that could be labeled with radioactive nuclides for the in vivo detection of boron.

  5. A microdosimetric study of {sup 10}B(n,{alpha}){sup 7}Li and {sup 157}Gd(n,{gamma}) reactions for neutron capture therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, C.K.C.; Sutton, M.; Evans, T.M.

    1999-01-01

    This paper presents the microdosimetric analysis for the most interesting cell survival experiment recently performed at the Brookhaven National Laboratory (BNL). In this experiment, the cells were first treated with a gadolinium (Gd) labeled tumor-seeking boronated porphyrin (Gd-BOPP) or with BOPP alone, and then irradiated with thermal neutrons. The resulting cell-survival curves indicate that the {sup 157}Gd(n,{gamma}) reactions are very effective in cell killing. The death of a cell treated with Gd-BOPP was attributed to either the {sup 10}B(n,{alpha}){sup 7}Li reactions or the {sup 157}Gd(n,{gamma}) reactions (or both). However, the quantitative relationship between the two types of reaction and themore » cell-survival fraction was not clear. This paper presents the microdosimetric analysis for the BNL experiment based on the measured experimental parameters, and the results clearly suggest a quantitative relationship between the two types of reaction and the cell survival fraction. The results also suggest new research in gadolinium neutron capture therapy (GdNCT) which may lead to a more practical modality than the boron neutron capture therapy (BNCT) for treating cancers.« less

  6. Preliminary dosimetric study on feasibility of multi-beam boron neutron capture therapy in patients with diffuse intrinsic pontine glioma without craniotomy.

    PubMed

    Lee, Jia-Cheng; Chuang, Keh-Shih; Chen, Yi-Wei; Hsu, Fang-Yuh; Chou, Fong-In; Yen, Sang-Hue; Wu, Yuan-Hung

    2017-01-01

    Diffuse intrinsic pontine glioma is a very frustrating disease. Since the tumor infiltrates the brain stem, surgical removal is often impossible. For conventional radiotherapy, the dose constraint of the brain stem impedes attempts at further dose escalation. Boron neutron capture therapy (BNCT), a targeted radiotherapy, carries the potential to selectively irradiate tumors with an adequate dose while sparing adjacent normal tissue. In this study, 12 consecutive patients treated with conventional radiotherapy in our institute were reviewed to evaluate the feasibility of BNCT. NCTPlan Ver. 1.1.44 was used for dose calculations. Compared with two and three fields, the average maximal dose to the normal brain may be lowered to 7.35 ± 0.72 Gy-Eq by four-field irradiation. The mean ratio of minimal dose to clinical target volume and maximal dose to normal tissue was 2.41 ± 0.26 by four-field irradiation. A therapeutic benefit may be expected with multi-field boron neutron capture therapy to treat diffuse intrinsic pontine glioma without craniotomy, while the maximal dose to the normal brain would be minimized by using the four-field setting.

  7. Preliminary dosimetric study on feasibility of multi-beam boron neutron capture therapy in patients with diffuse intrinsic pontine glioma without craniotomy

    PubMed Central

    Lee, Jia-Cheng; Chuang, Keh-Shih; Chen, Yi-Wei; Hsu, Fang-Yuh; Chou, Fong-In; Yen, Sang-Hue

    2017-01-01

    Diffuse intrinsic pontine glioma is a very frustrating disease. Since the tumor infiltrates the brain stem, surgical removal is often impossible. For conventional radiotherapy, the dose constraint of the brain stem impedes attempts at further dose escalation. Boron neutron capture therapy (BNCT), a targeted radiotherapy, carries the potential to selectively irradiate tumors with an adequate dose while sparing adjacent normal tissue. In this study, 12 consecutive patients treated with conventional radiotherapy in our institute were reviewed to evaluate the feasibility of BNCT. NCTPlan Ver. 1.1.44 was used for dose calculations. Compared with two and three fields, the average maximal dose to the normal brain may be lowered to 7.35 ± 0.72 Gy-Eq by four-field irradiation. The mean ratio of minimal dose to clinical target volume and maximal dose to normal tissue was 2.41 ± 0.26 by four-field irradiation. A therapeutic benefit may be expected with multi-field boron neutron capture therapy to treat diffuse intrinsic pontine glioma without craniotomy, while the maximal dose to the normal brain would be minimized by using the four-field setting. PMID:28662135

  8. 76 FR 61722 - National Heart, Lung, and Blood Institute; Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-05

    ... Institute Special Emphasis Panel, Data Coordinating Center for the Cardiovascular Cell Therapy Research... Special Emphasis Panel, Regional Clinical Center for the Cardiovascular Cell Therapy Research Network... Capture Agents for Cardiovascular Research. Date: October 24, 2011. Time: 1 p.m. to 3 p.m. Agenda: To...

  9. Dynamic infrared imaging for biological and medical applications in Boron neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Santa Cruz, Gustavo A.; González, Sara J.; Dagrosa, Alejandra; Schwint, Amanda E.; Carpano, Marina; Trivillin, Verónica A.; Boggio, Esteban F.; Bertotti, José; Marín, Julio; Monti Hughes, Andrea; Molinari, Ana J.; Albero, Miguel

    2011-05-01

    Boron Neutron Capture Therapy (BNCT) is a treatment modality, currently focused on the treatment of cancer, which involves a tumor selective 10B compound and a specially tuned neutron beam to produce a lethal nuclear reaction. BNCT kills target cells with microscopic selectivity while sparing normal tissues from potentially lethal doses of radiation. In the context of the Argentine clinical and research BNCT projects at the National Atomic Energy Commission and in a strong collaboration with INVAP SE, we successfully implemented Dynamic Infrared Imaging (DIRI) in the clinical setting for the observation of cutaneous melanoma patients and included DIRI as a non invasive methodology in several research protocols involving small animals. We were able to characterize melanoma lesions in terms of temperature and temperature rate-of-recovery after applying a mild cold thermal stress, distinguishing melanoma from other skin pigmented lesions. We observed a spatial and temporal correlation between skin acute reactions after irradiation, the temperature pattern and the dose distribution. We studied temperature distribution as a function of tumor growth in mouse xenografts, observing a significant correlation between tumor temperature and drug uptake; we investigated temperature evolution in the limbs of Wistar rats for a protocol of induced rheumatoid arthritis (RA), DIRI being especially sensitive to RA induction even before the development of clinical signs and studied surface characteristics of tumors, precancerous and normal tissues in a model of oral cancer in the hamster cheek pouch.

  10. Critical review, with an optimistic outlook, on Boron Neutron Capture Therapy (BNCT).

    PubMed

    Moss, Raymond L

    2014-06-01

    The first BNCT trials took place in the USA in the early 1960's, yet BNCT is still far from mainstream medicine. Nonetheless, in recent years, reported results in the treatment of head and neck cancer and recurrent glioma, coupled with the progress in developing linear accelerators specifically for BNCT applications, have given some optimism to the future of BNCT. This article provides a brief reminder on the ups and downs of the history of BNCT and supports the view that controlled and prospective clinical trials with a modern design will make BNCT an evidence-based treatment modality within the coming decade. © 2013 Elsevier Ltd. All rights reserved.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gilbert, Jack A.; Quinn, Robert A.; Debelius, Justine

    Rapid advances in DNA sequencing, metabolomics, proteomics and computational tools are dramatically increasing access to the microbiome and identification of its links with disease. In particular, time-series studies and multiple molecular perspectives are facilitating microbiome-wide association studies, which are analogous to genome-wide association studies. Early findings point to actionable outcomes of microbiome-wide association studies, although their clinical application has yet to be approved. An appreciation of the complexity of interactions among the microbiome and the host's diet, chemistry and health, as well as determining the frequency of observations that are needed to capture and integrate this dynamic interface, is paramountmore » for developing precision diagnostics and therapies that are based on the microbiome.« less

  12. Usability testing of an mHealth device for swallowing therapy in head and neck cancer survivors.

    PubMed

    Constantinescu, Gabriela; Kuffel, Kristina; King, Ben; Hodgetts, William; Rieger, Jana

    2018-04-01

    The objective of this study was to conduct the first patient usability testing of a mobile health (mHealth) system for in-home swallowing therapy. Five participants with a history of head and neck cancer evaluated the mHealth system. After completing an in-application (app) tutorial with the clinician, participants were asked to independently complete five tasks: pair the device to the smartphone, place the device correctly, exercise, interpret progress displays, and close the system. Quantitative and qualitative methods were used to evaluate the effectiveness, efficiency, and satisfaction with the system. Critical changes to the app were found in three of the tasks, resulting in recommendations for the next iteration. These issues were related to ease of Bluetooth pairing, placement of device, and interpretation of statistics. Usability testing with patients identified issues that were essential to address prior to implementing the mHealth system in subsequent clinical trials. Of the usability methods used, video observation (synced screen capture with videoed gestures) revealed the most information.

  13. Describing the clinical reasoning process: application of a model of enablement to a pediatric case.

    PubMed

    Furze, Jennifer; Nelson, Kelly; O'Hare, Megan; Ortner, Amanda; Threlkeld, A Joseph; Jensen, Gail M

    2013-04-01

    Clinical reasoning is a core tenet of physical therapy practice leading to optimal patient care. The purpose of this case was to describe the outcomes, subjective experience, and reflective clinical reasoning process for a child with cerebral palsy using the International Classification of Functioning, Disability, and Health (ICF) model. Application of the ICF framework to a 9-year-old boy with spastic triplegic cerebral palsy was utilized to capture the interwoven factors present in this case. Interventions in the pool occurred twice weekly for 1 h over a 10-week period. Immediately post and 4 months post-intervention, the child made functional and meaningful gains. The family unit also developed an enjoyment of exercising together. Each individual family member described psychological, emotional, or physical health improvements. Reflection using the ICF model as a framework to discuss clinical reasoning can highlight important factors contributing to effective patient management.

  14. Boron neutron capture therapy for malignant melanoma: first clinical case report in China

    PubMed Central

    Yong, Zhong; Song, Zewen; Zhou, Yongmao; Liu, Tong; Zhang, Zizhu; Zhao, Yanzhong; Chen, Yang; Jin, Congjun; Chen, Xiang; Lu, Jianyun; Han, Rui; Li, Pengzhou; Sun, Xulong; Wang, Guohui; Shi, Guangqing; Zhu, Shaihong

    2016-01-01

    A phase I/II clinical trial for treating malignant melanoma by boron neutron capture therapy (BNCT) was designed to evaluate whether the world’s first in-hospital neutron irradiator (IHNI) was qualified for BNCT. In this clinical trial planning to enroll 30 patients, the first case was treated on August 19, 2014. We present the protocol of this clinical trial, the treating procedure, and the clinical outcome of this first case. Only grade 2 acute radiation injury was observed during the first four weeks after BNCT and the injury healed after treatment. No late radiation injury was found during the 24-month follow-up. Based on positron emission tomography-computed tomography (PET/CT) scan, pathological analysis and gross examination, the patient showed a complete response to BNCT, indicating that BNCT is a potent therapy against malignant melanoma and IHNI has the potential to enable the delivery of BNCT in hospitals. PMID:28174492

  15. Monte Carlo calculations of lung dose in ORNL phantom for boron neutron capture therapy.

    PubMed

    Krstic, D; Markovic, V M; Jovanovic, Z; Milenkovic, B; Nikezic, D; Atanackovic, J

    2014-10-01

    Monte Carlo simulations were performed to evaluate dose for possible treatment of cancers by boron neutron capture therapy (BNCT). The computational model of male Oak Ridge National Laboratory (ORNL) phantom was used to simulate tumours in the lung. Calculations have been performed by means of the MCNP5/X code. In this simulation, two opposite neutron beams were considered, in order to obtain uniform neutron flux distribution inside the lung. The obtained results indicate that the lung cancer could be treated by BNCT under the assumptions of calculations. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Pilot clinical study of boron neutron capture therapy for recurrent hepatic cancer involving the intra-arterial injection of a (10)BSH-containing WOW emulsion.

    PubMed

    Yanagie, Hironobu; Higashi, Syushi; Seguchi, Koji; Ikushima, Ichiro; Fujihara, Mituteru; Nonaka, Yasumasa; Oyama, Kazuyuki; Maruyama, Syoji; Hatae, Ryo; Suzuki, Minoru; Masunaga, Shin-ichiro; Kinashi, Tomoko; Sakurai, Yoshinori; Tanaka, Hiroki; Kondo, Natsuko; Narabayashi, Masaru; Kajiyama, Tetsuya; Maruhashi, Akira; Ono, Koji; Nakajima, Jun; Ono, Minoru; Takahashi, Hiroyuki; Eriguchi, Masazumi

    2014-06-01

    A 63-year-old man with multiple HCC in his left liver lobe was enrolled as the first patient in a pilot study of boron neutron capture therapy (BNCT) involving the selective intra-arterial infusion of a (10)BSH-containing water-in-oil-in-water emulsion ((10)BSH-WOW). The size of the tumorous region remained stable during the 3 months after the BNCT. No adverse effects of the BNCT were observed. The present results show that (10)BSH-WOW can be used as novel intra-arterial boron carriers during BNCT for HCC. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Measurement of in-phantom neutron flux and gamma dose in Tehran research reactor boron neutron capture therapy beam line.

    PubMed

    Bavarnegin, Elham; Sadremomtaz, Alireza; Khalafi, Hossein; Kasesaz, Yaser

    2016-01-01

    Determination of in-phantom quality factors of Tehran research reactor (TRR) boron neutron capture therapy (BNCT) beam. The doses from thermal neutron reactions with 14N and 10B are calculated by kinetic energy released per unit mass approach, after measuring thermal neutron flux using neutron activation technique. Gamma dose is measured using TLD-700 dosimeter. Different dose components have been measured in a head phantom which has been designed and constructed for BNCT purpose in TRR. Different in-phantom beam quality factors have also been determined. This study demonstrates that the TRR BNCT beam line has potential for treatment of superficial tumors.

  18. 77 FR 14039 - Endangered and Threatened Wildlife and Plants; Permit Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-08

    ..., TN. The applicant requests a permit to take (capture and release) fat pocketbook (Potamilus capax... pearlymussel (Epioblasma obliquata perobliqua), Fanshell (Cyprogenia stegaria), Fat pocketbook, Higgins' eye...Science, Inc., Stow, OH. The applicant requests a permit renewal to take (capture and release) freshwater...

  19. Synthesis and biological evaluation of new BSH-conjugated chlorin derivatives as agents for both photodynamic therapy and boron neutron capture therapy of cancer.

    PubMed

    Asano, Ryuji; Nagami, Amon; Fukumoto, Yuki; Miura, Kaori; Yazama, Futoshi; Ito, Hideyuki; Sakata, Isao; Tai, Akihiro

    2014-11-01

    New disodium mercaptoundecahydro-closo-dodecaborate (BSH)-conjugated chlorin derivatives 11, 12, 16 and 20 as agents for both photodynamic therapy (PDT) and boron neutron capture therapy (BNCT) of cancer were synthesized. The in vivo biodistribution and clearance of 11, 12, 16 and 20 were investigated in tumor-bearing mice. Compounds 12 and 16 showed good tumor-selective accumulation among the four derivatives. The time to maximum accumulation of compound 16 in tumor tissue was one-fourth of that of compound 12, and clearance from normal tissues of compound 16 was similar to that of compound 12. The in vivo therapeutic efficacy of PDT using 16, which has twice as many boron atoms as 12, was evaluated by measuring tumor growth rates in tumor-bearing mice with 660 nm light-emitting diode irradiation at 6h after injection of 16. Tumor growth was significantly inhibited by PDT using 16. These results suggested that 16 is a good candidate for both PDT and BNCT of cancer. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Where biomedicalisation and magic meet: Therapeutic innovations of elite sports injury in British professional football and cycling.

    PubMed

    Faulkner, Alex; McNamee, Michael; Coveney, Catherine; Gabe, Jonathan

    2017-04-01

    Injury is a conspicuous feature of the practice and public spectacle of contemporary elite sports. The paper argues that the 'biomedicalisation' thesis (medico-industrial nexus, techno-scientific drivers, medical optimisation, biologisation, the rise of evidence and health surveillance) goes some way to capturing the use in elite sports injury of some highly specialised mainstream therapies and some highly maverick biological therapies, which are described. Nevertheless, these main strands of biomedicalisation do not capture the full range of these phenomena in the contexts of sports medicine and athletes' practices in accessing innovative, controversial therapies. Drawing on multi-method qualitative research on top-level professional football and cycling in the UK, 2014-2016, we argue that concepts of 'magic' and faith-based healing, mediated by notions of networking behaviour and referral systems, furnish a fuller explanation. We touch on the concept of 'medical pluralism', concluding that this should be revised in order to take account of belief-based access to innovative bio-therapies amongst elite sportspeople and organisations. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Analysis of MCNP simulated gamma spectra of CdTe detectors for boron neutron capture therapy.

    PubMed

    Winkler, Alexander; Koivunoro, Hanna; Savolainen, Sauli

    2017-06-01

    The next step in the boron neutron capture therapy (BNCT) is the real time imaging of the boron concentration in healthy and tumor tissue. Monte Carlo simulations are employed to predict the detector response required to realize single-photon emission computed tomography in BNCT, but have failed to correctly resemble measured data for cadmium telluride detectors. In this study we have tested the gamma production cross-section data tables of commonly used libraries in the Monte Carlo code MCNP in comparison to measurements. The cross section data table TENDL-2008-ACE is reproducing measured data best, whilst the commonly used ENDL92 and other studied libraries do not include correct tables for the gamma production from the cadmium neutron capture reaction that is occurring inside the detector. Furthermore, we have discussed the size of the annihilation peaks of spectra obtained by cadmium telluride and germanium detectors. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. A theoretical model for the production of Ac-225 for cancer therapy by neutron capture transmutation of Ra-226.

    PubMed

    Melville, G; Melville, P

    2013-02-01

    Radium needles that were once implanted into tumours as a cancer treatment are now obsolete and constitute a radioactive waste problem, as their half-life is 1600 years. We are investigating the reduction of radium by transmutation by bombarding Ra-226 with high-energy neutrons from a neutron source to produce Ra-225 and hence Ac-225, which can be used as a generator to produce Bi-213 for use in 'Targeted Alpha Therapy' for cancer. This paper examines the possibility of producing Ac-225 by neutron capture using a theoretical model in which neutron energy is convoluted with the corresponding neutron cross sections of Ra-226. The total integrated yield can then be obtained. This study shows that an intense beam of high-energy neutrons could initiate neutron capture on Ra-226 to produce Ra-225 and hence practical amounts of Ac-225 and a useful reduction of Ra-226. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Connected vehicle Data Capture and Management (DCM) and dynamic mobility applications (DMA) : assessment of relevant standards and gaps for candidate applications.

    DOT National Transportation Integrated Search

    2012-10-01

    The Connected Vehicle Mobility Standards Coordination Plan project links activities in three programs (Data Capture and Management, Dynamic Mobility Applications, and ITS Standards). The plan coordinates the timing, intent and relationship of activit...

  4. Prototype Development: Context-Driven Dynamic XML Ophthalmologic Data Capture Application

    PubMed Central

    Schwei, Kelsey M; Kadolph, Christopher; Finamore, Joseph; Cancel, Efrain; McCarty, Catherine A; Okorie, Asha; Thomas, Kate L; Allen Pacheco, Jennifer; Pathak, Jyotishman; Ellis, Stephen B; Denny, Joshua C; Rasmussen, Luke V; Tromp, Gerard; Williams, Marc S; Vrabec, Tamara R; Brilliant, Murray H

    2017-01-01

    Background The capture and integration of structured ophthalmologic data into electronic health records (EHRs) has historically been a challenge. However, the importance of this activity for patient care and research is critical. Objective The purpose of this study was to develop a prototype of a context-driven dynamic extensible markup language (XML) ophthalmologic data capture application for research and clinical care that could be easily integrated into an EHR system. Methods Stakeholders in the medical, research, and informatics fields were interviewed and surveyed to determine data and system requirements for ophthalmologic data capture. On the basis of these requirements, an ophthalmology data capture application was developed to collect and store discrete data elements with important graphical information. Results The context-driven data entry application supports several features, including ink-over drawing capability for documenting eye abnormalities, context-based Web controls that guide data entry based on preestablished dependencies, and an adaptable database or XML schema that stores Web form specifications and allows for immediate changes in form layout or content. The application utilizes Web services to enable data integration with a variety of EHRs for retrieval and storage of patient data. Conclusions This paper describes the development process used to create a context-driven dynamic XML data capture application for optometry and ophthalmology. The list of ophthalmologic data elements identified as important for care and research can be used as a baseline list for future ophthalmologic data collection activities. PMID:28903894

  5. Workshop on cancer biometrics: identifying biomarkers and surrogates of cancer in patients: a meeting held at the Masur Auditorium, National Institutes of Health.

    PubMed

    Lotze, Michael T; Wang, Ena; Marincola, Francesco M; Hanna, Nabil; Bugelski, Peter J; Burns, Christine A; Coukos, George; Damle, Nitin; Godfrey, Tony E; Howell, W Martin; Panelli, Monica C; Perricone, Michael A; Petricoin, Emanuel F; Sauter, Guido; Scheibenbogen, Carmen; Shivers, Steven C; Taylor, D Lansing; Weinstein, John N; Whiteside, Theresa L

    2005-01-01

    The current excitement about molecular targeted therapies has driven much of the recent dialog in cancer diagnosis and treatment. Particularly in the biologic therapy of cancer, identifiable antigenic T-cell targets restricted by MHC molecules and the related novel stress molecules such as MICA/B and Letal allow a degree of precision previously unknown in cancer therapy. We have previously held workshops on immunologic monitoring and angiogenesis monitoring. This workshop was designed to discuss the state of the art in identification of biomarkers and surrogates of tumor in patients with cancer, with particular emphasis on assays within the blood and tumor. We distinguish this from immunologic monitoring in the sense that it is primarily a measure of the tumor burden as opposed to the immune response to it. Recommendations for intensive investigation and targeted funding to enable such strategies were developed in seven areas: genomic analysis; detection of molecular markers in peripheral blood and lymph node by tumor capture and RT-PCR; serum, plasma, and tumor proteomics; immune polymorphisms; high content screening using flow and imaging cytometry; immunohistochemistry and tissue microarrays; and assessment of immune infiltrate and necrosis in tumors. Concrete recommendations for current application and enabling further development in cancer biometrics are summarized. This will allow a more informed, rapid, and accurate assessment of novel cancer therapies.

  6. Neutron capture therapy with deep tissue penetration using capillary neutron focusing

    DOEpatents

    Peurrung, Anthony J.

    1997-01-01

    An improved method for delivering thermal neutrons to a subsurface cancer or tumor which has been first doped with a dopant having a high cross section for neutron capture. The improvement is the use of a guide tube in cooperation with a capillary neutron focusing apparatus, or neutron focusing lens, for directing neutrons to the tumor, and thereby avoiding damage to surrounding tissue.

  7. 76 FR 21399 - Endangered and Threatened Wildlife and Plants; Permit Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-15

    ... immobilization, assess and treat health conditions, implant isotopes, salvage, and release) gray wolf (Canis... applicant requests a permit renewal to take (capture and release) Indiana bats (Myotissodalis) and gray bats..., OH. The applicant requests a permit renewal to take (capture and release) Indiana bats and gray bats...

  8. Experimental and Simulated Characterization of a Beam Shaping Assembly for Accelerator- Based Boron Neutron Capture Therapy (AB-BNCT)

    NASA Astrophysics Data System (ADS)

    Burlon, Alejandro A.; Girola, Santiago; Valda, Alejandro A.; Minsky, Daniel M.; Kreiner, Andrés J.

    2010-08-01

    In the frame of the construction of a Tandem Electrostatic Quadrupole Accelerator facility devoted to the Accelerator-Based Boron Neutron Capture Therapy, a Beam Shaping Assembly has been characterized by means of Monte-Carlo simulations and measurements. The neutrons were generated via the 7Li(p, n)7Be reaction by irradiating a thick LiF target with a 2.3 MeV proton beam delivered by the TANDAR accelerator at CNEA. The emerging neutron flux was measured by means of activation foils while the beam quality and directionality was evaluated by means of Monte Carlo simulations. The parameters show compliance with those suggested by IAEA. Finally, an improvement adding a beam collimator has been evaluated.

  9. Optimal moderator materials at various proton energies considering photon dose rate after irradiation for an accelerator-driven ⁹Be(p, n) boron neutron capture therapy neutron source.

    PubMed

    Hashimoto, Y; Hiraga, F; Kiyanagi, Y

    2015-12-01

    We evaluated the accelerator beam power and the neutron-induced radioactivity of (9)Be(p, n) boron neutron capture therapy (BNCT) neutron sources having a MgF2, CaF2, or AlF3 moderator and driven by protons with energy from 8 MeV to 30 MeV. The optimal moderator materials were found to be MgF2 for proton energies less than 10 MeV because of lower required accelerator beam power and CaF2 for higher proton energies because of lower photon dose rate at the treatment position after neutron irradiation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Boron nitride nanowires synthesis via a simple chemical vapor deposition at 1200 °C

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmad, Pervaiz; Khandaker, Mayeen Uddin; Amin, Yusoff Mohd

    2015-04-24

    A very simple chemical vapor deposition technique is used to synthesize high quality boron nitride nanowires at 1200 °C within a short growth duration of 30 min. FESEM micrograph shows that the as-synthesized boron nitride nanowires have a clear wire like morphology with diameter in the range of ∼20 to 150 nm. HR-TEM confirmed the wire-like structure of boron nitride nanowires, whereas XPS and Raman spectroscopy are used to find out the elemental composition and phase of the synthesized material. The synthesized boron nitride nanowires have potential applications as a sensing element in solid state neutron detector, neutron capture therapy and microelectronicmore » devices with uniform electronic properties.« less

  11. [Value-based medicine for glaucoma].

    PubMed

    Hirneiss, C; Kampik, A; Neubauer, A S

    2010-03-01

    The application of value-based medicine (VBM) tenets in the area of glaucoma research requires valid and reliable data concerning the quality of life with glaucoma. A multitude of instruments for measuring quality of life of patients with glaucoma have been employed in the past. Any instrument used would need to capture peripheral vision loss and its influence on patient-reported quality of life as this is one of the hallmarks of this disease. Cost-utility analyses can then be based on the reported quality of life and the cost of glaucoma therapy. Several cost-utility analyses have been applied in the field of glaucoma screening as well as treating ocular hypertension and based on this a recommendation regarding population subgroups which can be treated cost efficiently can be made.

  12. Grazing-Incidence Neutron Optics based on Wolter Geometries

    NASA Technical Reports Server (NTRS)

    Gubarev, M. V.; Ramsey, B. D.; Mildner, D. F. R.

    2008-01-01

    The feasibility of grazing-incidence neutron imaging optics based on the Wolter geometries have been successfully demonstrated. Biological microscopy, neutron radiography, medical imaging, neutron crystallography and boron neutron capture therapy would benefit from high resolution focusing neutron optics. Two bounce optics can also be used to focus neutrons in SANS experiments. Here, the use of the optics would result in lower values of obtainable scattering angles. The high efficiency of the optics permits a decrease in the minimum scattering vector without lowering the neutron intensity on sample. In this application, a significant advantage of the reflective optics over refractive optics is that the focus is independent of wavelength, so that the technique can be applied to polychromatic beams at pulsed neutron sources.

  13. Real-World Switching to Riociguat: Management and Practicalities in Patients with PAH and CTEPH.

    PubMed

    Gall, Henning; Vachiéry, Jean-Luc; Tanabe, Nobuhiro; Halank, Michael; Orozco-Levi, Mauricio; Mielniczuk, Lisa; Chang, MiKyung; Vogtländer, Kai; Grünig, Ekkehard

    2018-06-01

    A proportion of patients with pulmonary arterial hypertension (PAH) and chronic thromboembolic pulmonary hypertension (CTEPH) do not achieve treatment goals or experience side effects on their current therapy. In such cases, switching patients to a new drug while discontinuing the first may be a viable and appropriate treatment option. CAPTURE was designed to investigate how physicians manage the switching of patients to riociguat in real-world clinical practice. Observations from the study were used to assess whether recommendations in the riociguat prescribing information are reflected in clinical practice. CAPTURE was an international, multicenter, uncontrolled, retrospective chart review that collected data from patients with PAH or inoperable or persistent/recurrent CTEPH who switched to riociguat from another pulmonary hypertension (PH)-targeted medical therapy. The primary objective of the study was to understand the procedure undertaken in real-world clinical practice for patients switching to riociguat. Of 127 patients screened, 125 were enrolled in CAPTURE. The majority of patients switched from a phosphodiesterase type 5 inhibitor (PDE5i) to riociguat and the most common reason for switching was lack of efficacy. Physicians were already using the recommended treatment-free period when switching patients to riociguat from sildenafil, but a slightly longer period than recommended for tadalafil. In line with the contraindication, the majority of patients did not receive riociguat and PDE5i therapy concomitantly. Physicians also followed the recommended dose-adjustment procedure for riociguat. Switching to riociguat from another PH-targeted therapy may be feasible in real-world clinical practice in the context of the current recommendations.

  14. Robust object tracking techniques for vision-based 3D motion analysis applications

    NASA Astrophysics Data System (ADS)

    Knyaz, Vladimir A.; Zheltov, Sergey Y.; Vishnyakov, Boris V.

    2016-04-01

    Automated and accurate spatial motion capturing of an object is necessary for a wide variety of applications including industry and science, virtual reality and movie, medicine and sports. For the most part of applications a reliability and an accuracy of the data obtained as well as convenience for a user are the main characteristics defining the quality of the motion capture system. Among the existing systems for 3D data acquisition, based on different physical principles (accelerometry, magnetometry, time-of-flight, vision-based), optical motion capture systems have a set of advantages such as high speed of acquisition, potential for high accuracy and automation based on advanced image processing algorithms. For vision-based motion capture accurate and robust object features detecting and tracking through the video sequence are the key elements along with a level of automation of capturing process. So for providing high accuracy of obtained spatial data the developed vision-based motion capture system "Mosca" is based on photogrammetric principles of 3D measurements and supports high speed image acquisition in synchronized mode. It includes from 2 to 4 technical vision cameras for capturing video sequences of object motion. The original camera calibration and external orientation procedures provide the basis for high accuracy of 3D measurements. A set of algorithms as for detecting, identifying and tracking of similar targets, so for marker-less object motion capture is developed and tested. The results of algorithms' evaluation show high robustness and high reliability for various motion analysis tasks in technical and biomechanics applications.

  15. "Sequential" boron neutron capture therapy (BNCT): a novel approach to BNCT for the treatment of oral cancer in the hamster cheek pouch model.

    PubMed

    Molinari, Ana J; Pozzi, Emiliano C C; Monti Hughes, Andrea; Heber, Elisa M; Garabalino, Marcela A; Thorp, Silvia I; Miller, Marcelo; Itoiz, Maria E; Aromando, Romina F; Nigg, David W; Quintana, Jorge; Santa Cruz, Gustavo A; Trivillin, Verónica A; Schwint, Amanda E

    2011-04-01

    In the present study the therapeutic effect and potential toxicity of the novel "Sequential" boron neutron capture therapy (Seq-BNCT) for the treatment of oral cancer was evaluated in the hamster cheek pouch model at the RA-3 Nuclear Reactor. Two groups of animals were treated with "Sequential" BNCT, i.e., BNCT mediated by boronophenylalanine (BPA) followed by BNCT mediated by sodium decahydrodecaborate (GB-10) either 24 h (Seq-24h-BNCT) or 48 h (Seq-48h-BNCT) later. In an additional group of animals, BPA and GB-10 were administered concomitantly [(BPA + GB-10)-BNCT]. The single-application BNCT was to the same total physical tumor dose as the "Sequential" BNCT treatments. At 28 days post-treatment, Seq-24h-BNCT and Seq-48h-BNCT induced, respectively, overall tumor responses of 95 ± 2% and 91 ± 3%, with no statistically significant differences between protocols. Overall response for the single treatment with (BPA + GB-10)-BNCT was 75 ± 5%, significantly lower than for Seq-BNCT. Both Seq-BNCT protocols and (BPA + GB-10)-BNCT induced reversible mucositis in the dose-limiting precancerous tissue around treated tumors, reaching Grade 3/4 mucositis in 47 ± 12% and 60 ± 22% of the animals, respectively. No normal tissue toxicity was associated with tumor response for any of the protocols. "Sequential" BNCT enhanced tumor response without an increase in mucositis in dose-limiting precancerous tissue. © 2011 by Radiation Research Society

  16. Neutron capture therapy with deep tissue penetration using capillary neutron focusing

    DOEpatents

    Peurrung, A.J.

    1997-08-19

    An improved method is disclosed for delivering thermal neutrons to a subsurface cancer or tumor which has been first doped with a dopant having a high cross section for neutron capture. The improvement is the use of a guide tube in cooperation with a capillary neutron focusing apparatus, or neutron focusing lens, for directing neutrons to the tumor, and thereby avoiding damage to surrounding tissue. 1 fig.

  17. Boron Neutron Capture Therapy (BNCT) Dose Calculation using Geometrical Factors Spherical Interface for Glioblastoma Multiforme

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zasneda, Sabriani; Widita, Rena

    2010-06-22

    Boron Neutron Capture Therapy (BNCT) is a cancer therapy by utilizing thermal neutron to produce alpha particles and lithium nuclei. The superiority of BNCT is that the radiation effects could be limited only for the tumor cells. BNCT radiation dose depends on the distribution of boron in the tumor. Absorbed dose to the cells from the reaction 10B (n, {alpha}) 7Li was calculated near interface medium containing boron and boron-free region. The method considers the contribution of the alpha particle and recoiled lithium particle to the absorbed dose and the variation of Linear Energy Transfer (LET) charged particles energy. Geometricalmore » factor data of boron distribution for the spherical surface is used to calculate the energy absorbed in the tumor cells, brain and scalp for case Glioblastoma Multiforme. The result shows that the optimal dose in tumor is obtained for boron concentrations of 22.1 mg {sup 10}B/g blood.« less

  18. Advances in boron neutron capture therapy (BNCT) at kyoto university - From reactor-based BNCT to accelerator-based BNCT

    NASA Astrophysics Data System (ADS)

    Sakurai, Yoshinori; Tanaka, Hiroki; Takata, Takushi; Fujimoto, Nozomi; Suzuki, Minoru; Masunaga, Shinichiro; Kinashi, Yuko; Kondo, Natsuko; Narabayashi, Masaru; Nakagawa, Yosuke; Watanabe, Tsubasa; Ono, Koji; Maruhashi, Akira

    2015-07-01

    At the Kyoto University Research Reactor Institute (KURRI), a clinical study of boron neutron capture therapy (BNCT) using a neutron irradiation facility installed at the research nuclear reactor has been regularly performed since February 1990. As of November 2014, 510 clinical irradiations were carried out using the reactor-based system. The world's first accelerator-based neutron irradiation system for BNCT clinical irradiation was completed at this institute in early 2009, and the clinical trial using this system was started in 2012. A shift of BCNT from special particle therapy to a general one is now in progress. To promote and support this shift, improvements to the irradiation system, as well as its preparation, and improvements in the physical engineering and the medical physics processes, such as dosimetry systems and quality assurance programs, must be considered. The recent advances in BNCT at KURRI are reported here with a focus on physical engineering and medical physics topics.

  19. Perspectives of boron-neutron capture therapy of malignant brain tumors

    NASA Astrophysics Data System (ADS)

    Kanygin, V. V.; Kichigin, A. I.; Krivoshapkin, A. L.; Taskaev, S. Yu.

    2017-09-01

    Boron neutron capture therapy (BNCT) is characterized by a selective effect directly on the cells of malignant tumors. The carried out research showed the perspective of the given kind of therapy concerning malignant tumors of the brain. However, the introduction of BNCT into clinical practice is hampered by the lack of a single protocol for the treatment of patients and the difficulty in using nuclear reactors to produce a neutron beam. This problem can be solved by using a compact accelerator as a source of neutrons, with the possibility of installation in a medical institution. Such a neutron accelerator for BNCT was developed at Budker Institute of Nuclear Physics, Novosibirsk. A neutron beam was obtained on this accelerator, which fully complies with the requirements of BNCT, as confirmed by studies on cell cultures and experiments with laboratory animals. The conducted experiments showed the relative safety of the method with the absence of negative effects on cell cultures and living organisms, and also confirmed the effectiveness of BNCT for malignant brain tumors.

  20. Comparative A/B testing a mobile data acquisition app for hydrogeochemistry

    NASA Astrophysics Data System (ADS)

    Klump, Jens; Golodoniuc, Pavel; Reid, Nathan; Gray, David; Ross, Shawn

    2015-04-01

    In the context of a larger study on the Capricorn Orogen of Western Australia, the CSIRO Mineral Discovery Program is conducting a regional study of the hydrogeochemistry on water from agricultural and other bores. Over time, the sampling process was standardised and a form for capturing metadata and data from initial measurements was developed. In 2014 an extensive technology review was conducted with an aim to automate field data acquisition process. A prototype hydrogeochemistry data capture form was implemented as a mobile application for Windows Mobile devices. This version of the software was a standalone application with an interface to export data as CSV files. A second candidate version of the hydrogeochemistry data capture form was implemented as an Android mobile application in the FAIMS framework. FAIMS is a framework for mobile field data capture, originally developed by at the University of New South Wales for archaeological field data collection. A benefit of the FAIMS application was the ability to associate photographs taken with the device's embedded camera with the captured data. FAIMS also allows networked collaboration within a field team, using the mobile applications as asynchronous rich clients. The network infrastructure can be installed in the field ("FAIMS in a Box") to supply data synchronisation, backup and transfer. This aspect will be tested in the next field season. A benefit of the FAIMS application was the ability to associate photographs taken with the device's embedded camera with the captured data. Having two data capture applications available allowed us to conduct an A/B test, comparing two different implementations for the same task. Both applications were trialled in the field by different field crews and user feedback will be used to improve the usability of the app for the next field season. A key learning was that the ergonomics of the app is at paramount importance to gain the user acceptance. This extends from general fit with the standard procedures used in the field during data acquisition to self-descriptive and intuitive user interface features well aligned with the workflows and sequence of actions performed by a user that ultimately contributes to the implementation of a Collect-As-You-Go approach. In the Australian outback, issues such as absence of network connectivity, heat and sun glare may challenge the utility of tablet based applications in the field. Due to limitations of tablet use in the field we also consider the use of smart pens for data capture. A smart pen application based on Anoto forms and software by Formidable will be tested in the next field season.

  1. Capture-based next-generation sequencing reveals multiple actionable mutations in cancer patients failed in traditional testing.

    PubMed

    Xie, Jing; Lu, Xiongxiong; Wu, Xue; Lin, Xiaoyi; Zhang, Chao; Huang, Xiaofang; Chang, Zhili; Wang, Xinjing; Wen, Chenlei; Tang, Xiaomei; Shi, Minmin; Zhan, Qian; Chen, Hao; Deng, Xiaxing; Peng, Chenghong; Li, Hongwei; Fang, Yuan; Shao, Yang; Shen, Baiyong

    2016-05-01

    Targeted therapies including monoclonal antibodies and small molecule inhibitors have dramatically changed the treatment of cancer over past 10 years. Their therapeutic advantages are more tumor specific and with less side effects. For precisely tailoring available targeted therapies to each individual or a subset of cancer patients, next-generation sequencing (NGS) has been utilized as a promising diagnosis tool with its advantages of accuracy, sensitivity, and high throughput. We developed and validated a NGS-based cancer genomic diagnosis targeting 115 prognosis and therapeutics relevant genes on multiple specimen including blood, tumor tissue, and body fluid from 10 patients with different cancer types. The sequencing data was then analyzed by the clinical-applicable analytical pipelines developed in house. We have assessed analytical sensitivity, specificity, and accuracy of the NGS-based molecular diagnosis. Also, our developed analytical pipelines were capable of detecting base substitutions, indels, and gene copy number variations (CNVs). For instance, several actionable mutations of EGFR,PIK3CA,TP53, and KRAS have been detected for indicating drug susceptibility and resistance in the cases of lung cancer. Our study has shown that NGS-based molecular diagnosis is more sensitive and comprehensive to detect genomic alterations in cancer, and supports a direct clinical use for guiding targeted therapy.

  2. Video Screen Capture Basics

    ERIC Educational Resources Information Center

    Dunbar, Laura

    2014-01-01

    This article is an introduction to video screen capture. Basic information of two software programs, QuickTime for Mac and BlueBerry Flashback Express for PC, are also discussed. Practical applications for video screen capture are given.

  3. Outcomes of Treatment Targeting Syntax Production in People with Broca's-Type Aphasia: Evidence from Psycholinguistic Assessment Tasks and Everyday Conversation

    ERIC Educational Resources Information Center

    Carragher, Marcella; Sage, Karen; Conroy, Paul

    2015-01-01

    Background: Capturing evidence of the effects of therapy within everyday communication is the holy grail of aphasia treatment design and evaluation. Whilst impaired sentence production is a predominant symptom of Broca's-type aphasia, the effects of sentence production therapy on everyday conversation have not been investigated. Given the…

  4. Therapeutic efficacy for hepatocellular carcinoma by boric acid-mediated boron neutron capture therapy in a rat model.

    PubMed

    Lin, Sy-Yu; Lin, Chen-Jou; Liao, Jiunn-Wang; Peir, Jinn-Jer; Chen, Wei-Lin; Chi, Chin-Wen; Lin, Yung-Chang; Liu, Yu-Ming; Chou, Fong-In

    2013-11-01

    Hepatocellular carcinoma (HCC) is a common malignant tumor with poor prognosis. Boron neutron capture therapy (BNCT) may provide an alternative therapy for HCC. This study investigated the therapeutic efficacy of boric acid (BA)-mediated BNCT for HCC in a rat model. The pharmacokinetic and biodistribution of BA in N1S1 tumor-bearing rats were analyzed. Rats were injected with 25 mg B/kg body weight via tail veins before neutron irradiation at the Tsing Hua Open-pool Reactor, and the efficacy of BNCT was evaluated from the tumor size, tumor blood flow, and biochemical analyses. HCC-bearing rats administered BNCT showed reductions in tumor size on ultrasound imaging, as well as an obvious reduction in the distribution of tumor blood flow. The lesion located in livers had disappeared on the 80th day after BNCT; a recovery of values to normal levels was also recorded. BA-mediated BNCT is a promising alternative for liver cancer therapy since the present study demonstrated the feasibility of curing a liver tumor and restoring liver function in rats. Efforts are underway to investigate the histopathological features and the detailed mechanisms of BA-mediated BNCT.

  5. Connected vehicle data capture and management (DCM) and dynamic mobility applications (DMA) : focused standards coordination plan.

    DOT National Transportation Integrated Search

    2012-11-01

    The Connected Vehicle Mobility Standards Coordination Plan project links activities in three programs (Data Capture and Management, Dynamic Mobility Applications, and ITS Standards). The plan coordinates the timing, intent and relationship of activit...

  6. Comparison between two portable devices for widefield PpIX fluorescence during cervical intraepithelial neoplasia treatment

    NASA Astrophysics Data System (ADS)

    Carbinatto, Fernanda M.; Inada, Natalia Mayumi; Lombardi, Welington; Cossetin, Natália Fernandez; Varoto, Cinthia; Kurachi, Cristina; Bagnato, Vanderlei Salvador

    2015-06-01

    The use of portable electronic devices, in particular mobile phones such as smartphones is increasing not only for all known applications, but also for diagnosis of diseases and monitoring treatments like topical Photodynamic Therapy. The aim of the study is to evaluate the production of the photosensitizer Protoporphyrin IX (PpIX) after topical application of a cream containing methyl aminolevulinate (MAL) in the cervix with diagnosis of Cervical Intraepithelial Neoplasia (CIN) through the fluorescence images captured after one and three hours and compare the images using two devices (a Sony Xperia® mobile and an Apple Ipod®. Was observed an increasing fluorescence intensity of the cervix three hours after cream application, in both portable electronic devices. However, because was used a specific program for the treatment of images using the Ipod® device, these images presented better resolution than observed by the Sony cell phone without a specific program. One hour after cream application presented a more selective fluorescence than the group of three hours. In conclusion, the use of portable devices to obtain images of PpIX fluorescence shown to be an effective tool and is necessary the improvement of programs for achievement of better results.

  7. Monitor Network Traffic with Packet Capture (pcap) on an Android Device

    DTIC Science & Technology

    2015-09-01

    administrative privileges . Under the current design Android development requirement, an Android Graphical User Interface (GUI) application cannot directly...build an Android application to monitor network traffic using open source packet capture (pcap) libraries. 15. SUBJECT TERMS ELIDe, Android , pcap 16...Building Application with Native Codes 5 8.1 Calling Native Codes Using JNI 5 8.2 Calling Native Codes from an Android Application 8 9. Retrieve Live

  8. Study on High Speed Lithium Jet For Neutron Source of Boron Neutron Capture Therapy (BNCT)

    NASA Astrophysics Data System (ADS)

    Takahashi, Minoru; Kobayashi, Tooru; Zhang, Mingguang; Mák, Michael; Štefanica, Jirí; Dostál, Václav; Zhao, Wei

    The feasibility study of a liquid lithium type proton beam target was performed for the neutron source of the boron neutron capture therapy (BNCT). As the candidates of the liquid lithium target, a thin sheet jet and a thin film flow on a concave wall were chosen, and a lithium flow experiment was conducted to investigate the hydrodynamic stability of the targets. The surfaces of the jets and film flows with a thickness of 0.5 mm and a width of 50 mm were observed by means of photography. It has been found that a stable sheet jet and a stable film flow on a concave wall can be formed up to certain velocities by using a straight nozzle and a curved nozzle with the concave wall, respectively.

  9. Boron neutron capture therapy (BNCT) in Finland: technological and physical prospects after 20 years of experiences.

    PubMed

    Savolainen, Sauli; Kortesniemi, Mika; Timonen, Marjut; Reijonen, Vappu; Kuusela, Linda; Uusi-Simola, Jouni; Salli, Eero; Koivunoro, Hanna; Seppälä, Tiina; Lönnroth, Nadja; Välimäki, Petteri; Hyvönen, Heini; Kotiluoto, Petri; Serén, Tom; Kuronen, Antti; Heikkinen, Sami; Kosunen, Antti; Auterinen, Iiro

    2013-05-01

    Boron Neutron Capture Therapy (BNCT) is a binary radiotherapy method developed to treat patients with certain malignant tumours. To date, over 300 treatments have been carried out at the Finnish BNCT facility in various on-going and past clinical trials. In this technical review, we discuss our research work in the field of medical physics to form the groundwork for the Finnish BNCT patient treatments, as well as the possibilities to further develop and optimize the method in the future. Accordingly, the following aspects are described: neutron sources, beam dosimetry, treatment planning, boron imaging and determination, and finally the possibilities to detect the efficacy and effects of BNCT on patients. Copyright © 2012 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  10. Accelerator-driven boron neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Edgecock, Rob

    2014-05-01

    Boron Neutron Capture Therapy is a binary treatment for certain types of cancer. It works by loading the cancerous cells with a boron-10 carrying compound. This isotope has a large cross-section for thermal neutrons, the reaction producing a lithium nucleus and alpha particle that kill the cell in which they are produced. Recent studies of the boron carrier compound indicate that the uptake process works best in particularly aggressive cancers. Most studied is glioblastoma multiforme and a trial using a combination of BNCT and X-ray radiotherapy has shown an increase of nearly a factor of two in mean survival over the state of the art. However, the main technical problem with BNCT remains producing a sufficient flux of neutrons for a reasonable treatment duration in a hospital environment. This paper discusses this issue.

  11. Hybrid data capture for monitoring patients on highly active antiretroviral therapy (HAART) in urban Botswana.

    PubMed

    Bussmann, Hermann; Wester, C William; Ndwapi, Ndwapi; Vanderwarker, Chris; Gaolathe, Tendani; Tirelo, Geoffrey; Avalos, Ava; Moffat, Howard; Marlink, Richard G

    2006-02-01

    Individual patient care and programme evaluation are pivotal for the success of antiretroviral treatment programmes in resource-limited countries. While computer-aided documentation and data storage are indispensable for any large programme, several important issues need to be addressed including which data are to be collected, who collects it and how it is entered into an electronic database. We describe a patient-monitoring approach, which uses patient encounter forms (in hybrid paper + electronic format) based on optical character recognition, piloted at Princess Marina Hospital in Gaborone, Botswana's first public highly active antiretroviral therapy (HAART) outpatient clinic. Our novel data capture approach collects "key" data for tracking patient and programme outcomes. It saves physician time and does not detract from clinical care.

  12. Hybrid data capture for monitoring patients on highly active antiretroviral therapy (HAART) in urban Botswana.

    PubMed Central

    Bussmann, Hermann; Wester, C. William; Ndwapi, Ndwapi; Vanderwarker, Chris; Gaolathe, Tendani; Tirelo, Geoffrey; Avalos, Ava; Moffat, Howard; Marlink, Richard G.

    2006-01-01

    Individual patient care and programme evaluation are pivotal for the success of antiretroviral treatment programmes in resource-limited countries. While computer-aided documentation and data storage are indispensable for any large programme, several important issues need to be addressed including which data are to be collected, who collects it and how it is entered into an electronic database. We describe a patient-monitoring approach, which uses patient encounter forms (in hybrid paper + electronic format) based on optical character recognition, piloted at Princess Marina Hospital in Gaborone, Botswana's first public highly active antiretroviral therapy (HAART) outpatient clinic. Our novel data capture approach collects "key" data for tracking patient and programme outcomes. It saves physician time and does not detract from clinical care. PMID:16501730

  13. Prototype Development: Context-Driven Dynamic XML Ophthalmologic Data Capture Application.

    PubMed

    Peissig, Peggy; Schwei, Kelsey M; Kadolph, Christopher; Finamore, Joseph; Cancel, Efrain; McCarty, Catherine A; Okorie, Asha; Thomas, Kate L; Allen Pacheco, Jennifer; Pathak, Jyotishman; Ellis, Stephen B; Denny, Joshua C; Rasmussen, Luke V; Tromp, Gerard; Williams, Marc S; Vrabec, Tamara R; Brilliant, Murray H

    2017-09-13

    The capture and integration of structured ophthalmologic data into electronic health records (EHRs) has historically been a challenge. However, the importance of this activity for patient care and research is critical. The purpose of this study was to develop a prototype of a context-driven dynamic extensible markup language (XML) ophthalmologic data capture application for research and clinical care that could be easily integrated into an EHR system. Stakeholders in the medical, research, and informatics fields were interviewed and surveyed to determine data and system requirements for ophthalmologic data capture. On the basis of these requirements, an ophthalmology data capture application was developed to collect and store discrete data elements with important graphical information. The context-driven data entry application supports several features, including ink-over drawing capability for documenting eye abnormalities, context-based Web controls that guide data entry based on preestablished dependencies, and an adaptable database or XML schema that stores Web form specifications and allows for immediate changes in form layout or content. The application utilizes Web services to enable data integration with a variety of EHRs for retrieval and storage of patient data. This paper describes the development process used to create a context-driven dynamic XML data capture application for optometry and ophthalmology. The list of ophthalmologic data elements identified as important for care and research can be used as a baseline list for future ophthalmologic data collection activities. ©Peggy Peissig, Kelsey M Schwei, Christopher Kadolph, Joseph Finamore, Efrain Cancel, Catherine A McCarty, Asha Okorie, Kate L Thomas, Jennifer Allen Pacheco, Jyotishman Pathak, Stephen B Ellis, Joshua C Denny, Luke V Rasmussen, Gerard Tromp, Marc S Williams, Tamara R Vrabec, Murray H Brilliant. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 13.09.2017.

  14. Microchip-Based Single-Cell Functional Proteomics for Biomedical Applications

    PubMed Central

    Lu, Yao; Yang, Liu; Wei, Wei; Shi, Qihui

    2017-01-01

    Cellular heterogeneity has been widely recognized but only recently have single cell tools become available that allow characterizing heterogeneity at the genomic and proteomic levels. We review the technological advances in microchip-based toolkits for single-cell functional proteomics. Each of these tools has distinct advantages and limitations, and a few have advanced toward being applied to address biological or clinical problems that fail to be addressed by traditional population-based methods. High-throughput single-cell proteomic assays generate high-dimensional data sets that contain new information and thus require developing new analytical framework to extract new biology. In this review article, we highlight a few biological and clinical applications in which the microchip-based single-cell proteomic tools provide unique advantages. The examples include resolving functional heterogeneity and dynamics of immune cells, dissecting cell-cell interaction by creating well-contolled on-chip microenvironment, capturing high-resolution snapshots of immune system functions in patients for better immunotherapy and elucidating phosphoprotein signaling networks in cancer cells for guiding effective molecularly targeted therapies. PMID:28280819

  15. Synthesis of immunotargeted magneto-plasmonic nanoclusters.

    PubMed

    Wu, Chun-Hsien; Sokolov, Konstantin

    2014-08-22

    Magnetic and plasmonic properties combined in a single nanoparticle provide a synergy that is advantageous in a number of biomedical applications including contrast enhancement in novel magnetomotive imaging modalities, simultaneous capture and detection of circulating tumor cells (CTCs), and multimodal molecular imaging combined with photothermal therapy of cancer cells. These applications have stimulated significant interest in development of protocols for synthesis of magneto-plasmonic nanoparticles with optical absorbance in the near-infrared (NIR) region and a strong magnetic moment. Here, we present a novel protocol for synthesis of such hybrid nanoparticles that is based on an oil-in-water microemulsion method. The unique feature of the protocol described herein is synthesis of magneto-plasmonic nanoparticles of various sizes from primary blocks which also have magneto-plasmonic characteristics. This approach yields nanoparticles with a high density of magnetic and plasmonic functionalities which are uniformly distributed throughout the nanoparticle volume. The hybrid nanoparticles can be easily functionalized by attaching antibodies through the Fc moiety leaving the Fab portion that is responsible for antigen binding available for targeting.

  16. Application and comparison of large-scale solution-based DNA capture-enrichment methods on ancient DNA

    PubMed Central

    Ávila-Arcos, María C.; Cappellini, Enrico; Romero-Navarro, J. Alberto; Wales, Nathan; Moreno-Mayar, J. Víctor; Rasmussen, Morten; Fordyce, Sarah L.; Montiel, Rafael; Vielle-Calzada, Jean-Philippe; Willerslev, Eske; Gilbert, M. Thomas P.

    2011-01-01

    The development of second-generation sequencing technologies has greatly benefitted the field of ancient DNA (aDNA). Its application can be further exploited by the use of targeted capture-enrichment methods to overcome restrictions posed by low endogenous and contaminating DNA in ancient samples. We tested the performance of Agilent's SureSelect and Mycroarray's MySelect in-solution capture systems on Illumina sequencing libraries built from ancient maize to identify key factors influencing aDNA capture experiments. High levels of clonality as well as the presence of multiple-copy sequences in the capture targets led to biases in the data regardless of the capture method. Neither method consistently outperformed the other in terms of average target enrichment, and no obvious difference was observed either when two tiling designs were compared. In addition to demonstrating the plausibility of capturing aDNA from ancient plant material, our results also enable us to provide useful recommendations for those planning targeted-sequencing on aDNA. PMID:22355593

  17. Mobile Motion Capture--MiMiC.

    PubMed

    Harbert, Simeon D; Jaiswal, Tushar; Harley, Linda R; Vaughn, Tyler W; Baranak, Andrew S

    2013-01-01

    The low cost, simple, robust, mobile, and easy to use Mobile Motion Capture (MiMiC) system is presented and the constraints which guided the design of MiMiC are discussed. The MiMiC Android application allows motion data to be captured from kinematic modules such as Shimmer 2r sensors over Bluetooth. MiMiC is cost effective and can be used for an entire day in a person's daily routine without being intrusive. MiMiC is a flexible motion capture system which can be used for many applications including fall detection, detection of fatigue in industry workers, and analysis of individuals' work patterns in various environments.

  18. New teaching aid “Physical Methods of Medical Introscopy”

    NASA Astrophysics Data System (ADS)

    Ulin, S. E.

    2017-01-01

    Description of a new teaching aid, in which new methods of reconstruction of hidden images by means of nuclear magnetic resonance, X-gamma-ray, and ultrasonic tomography, is presented. The diagnostics and therapy methods of various oncological diseases with the use of medicine proton and ions beams, as well as neutron capture therapy, are considered. The new teaching aid is intended for senior students and postgraduates.

  19. Evaluation of a novel sodium borocaptate-containing unnatural amino acid as a boron delivery agent for neutron capture therapy of the F98 rat glioma.

    PubMed

    Futamura, Gen; Kawabata, Shinji; Nonoguchi, Naosuke; Hiramatsu, Ryo; Toho, Taichiro; Tanaka, Hiroki; Masunaga, Shin-Ichiro; Hattori, Yoshihide; Kirihata, Mitsunori; Ono, Koji; Kuroiwa, Toshihiko; Miyatake, Shin-Ichi

    2017-01-23

    Boron neutron capture therapy (BNCT) is a unique particle radiation therapy based on the nuclear capture reactions in boron-10. We developed a novel boron-10 containing sodium borocaptate (BSH) derivative, 1-amino-3-fluorocyclobutane-1-carboxylic acid (ACBC)-BSH. ACBC is a tumor selective synthetic amino acid. The purpose of this study was to assess the biodistribution of ACBC-BSH and its therapeutic efficacy following Boron Neutron Capture Therapy (BNCT) of the F98 rat glioma. We evaluated the biodistribution of three boron-10 compounds, ACBC-BSH, BSH and boronophenylalanine (BPA), in vitro and in vivo, following intravenous (i.v.) administration and intratumoral (i.t.) convection-enhanced delivery (CED) in F98 rat glioma bearing rats. For BNCT studies, rats were stratified into five groups: untreated controls, neutron-irradiation controls, BNCT with BPA/i.v., BNCT with ACBC-BSH/CED, and BNCT concomitantly using BPA/i.v. and ACBC-BSH/CED. In vitro, ACBC-BSH attained higher cellular uptake F98 rat glioma cells compared with BSH. In vivo biodistribution studies following i.v. administration and i.t. CED of ACBC-BSH attained significantly higher boron concentrations than that of BSH, but much lower than that of BPA. However, following convection enhanced delivery (CED), ACBC-BSH attained significantly higher tumor concentrations than BPA. The i.t. boron-10 concentrations were almost equal between the ACBC-BSH/CED group and BPA/i.v. group of rats. The tumor/brain boron-10 concentration ratio was higher with ACBC-BSH/CED than that of BPA/i.v. group. Based on these data, BNCT studies were carried out in F98 glioma bearing rats using BPA/i.v. and ACBC-BSH/CED as the delivery agents. The corresponding mean survival times were 37.4 ± 2.6d and 44.3 ± 8.0d, respectively, and although modest, these differences were statistically significant. Our findings suggest that further studies are warranted to evaluate ACBC-BSH/CED as a boron delivery agent.

  20. Orbiting Sample Capture and Orientation Technologies for Potential Mars Sample Return

    NASA Astrophysics Data System (ADS)

    Younse, P.; Adajian, R.; Dolci, M.; Ohta, P.; Olds, E.; Lalla, K.; Strahle, J. W.

    2018-04-01

    Technologies applicable to a potential Mars Sample Return Orbiter for orbiting sample container capture and orientation are presented, as well as an integrated MArs CApture and ReOrientation for a potential NExt Mars Orbiter (MACARONE) concept.

  1. Measurement of the intensity ratio of Auger and conversion electrons for the electron capture decay of 125I.

    PubMed

    Alotiby, M; Greguric, I; Kibédi, T; Lee, B Q; Roberts, M; Stuchbery, A E; Tee, Pi; Tornyi, T; Vos, M

    2018-03-21

    Auger electrons emitted after nuclear decay have potential application in targeted cancer therapy. For this purpose it is important to know the Auger electron yield per nuclear decay. In this work we describe a measurement of the ratio of the number of conversion electrons (emitted as part of the nuclear decay process) to the number of Auger electrons (emitted as part of the atomic relaxation process after the nuclear decay) for the case of 125 I. Results are compared with Monte-Carlo type simulations of the relaxation cascade using the BrIccEmis code. Our results indicate that for 125 I the calculations based on rates from the Evaluated Atomic Data Library underestimate the K Auger yields by 20%.

  2. Neutron collimator design of neutron radiography based on the BNCT facility

    NASA Astrophysics Data System (ADS)

    Yang, Xiao-Peng; Yu, Bo-Xiang; Li, Yi-Guo; Peng, Dan; Lu, Jin; Zhang, Gao-Long; Zhao, Hang; Zhang, Ai-Wu; Li, Chun-Yang; Liu, Wan-Jin; Hu, Tao; Lü, Jun-Guang

    2014-02-01

    For the research of CCD neutron radiography, a neutron collimator was designed based on the exit of thermal neutron of the Boron Neutron Capture Therapy (BNCT) reactor. Based on the Geant4 simulations, the preliminary choice of the size of the collimator was determined. The materials were selected according to the literature data. Then, a collimator was constructed and tested on site. The results of experiment and simulation show that the thermal neutron flux at the end of the neutron collimator is greater than 1.0×106 n/cm2/s, the maximum collimation ratio (L/D) is 58, the Cd-ratio(Mn) is 160 and the diameter of collimator end is 10 cm. This neutron collimator is considered to be applicable for neutron radiography.

  3. Silica nanoparticles carrying boron-containing polymer brushes

    NASA Astrophysics Data System (ADS)

    Brozek, Eric M.; Mollard, Alexis H.; Zharov, Ilya

    2014-05-01

    A new class of surface-modified silica nanoparticles has been developed for potential applications in boron neutron capture therapy. Sub-50 nm silica particles were synthesized using a modified Stöber method and used in surface-initiated atom transfer radical polymerization of two biocompatible polymers, poly(2-(hydroxyethyl)methacrylate) and poly(2-(methacryloyloxy)ethyl succinate). The carboxylic acid and hydroxyl functionalities of the polymeric side chains were functionalized with carboranyl clusters in high yields. The resulting particles were characterized using DLS, TEM, solution 1H NMR, solid state 11B NMR and thermogravimetric analysis. The particles contain between 13 and 18 % of boron atoms by weight, which would provide a high amount of 10B nuclides for BNCT, while the polymer chains are suitable for further modification with cell targeting ligands.

  4. Particle induced nuclear reaction calculations of Boron target nuclei

    NASA Astrophysics Data System (ADS)

    Tel, Eyyup; Sahan, Muhittin; Sarpün, Ismail Hakki; Kavun, Yusuf; Gök, Ali Armagan; Poyraz, Meltem

    2017-09-01

    Boron is usable element in many areas such as health, industry and energy. Especially, Boron neutron capture therapy (BNCT) is one of the medical applications. Boron target is irradiated with low energy thermal neutrons and at the end of reactions alpha particles occur. After this process recoiling lithium-7 nuclei is composed. In this study, charge particle induced nuclear reactions calculations of Boron target nuclei were investigated in the incident proton and alpha energy range of 5-50 MeV. The excitation functions for 10B target nuclei reactions have been calculated by using PCROSS Programming code. The semi-empirical calculations for (p,α) reactions have been done by using cross section formula with new coefficient obtained by Tel et al. The calculated results were compared with the experimental data from the literature.

  5. Chemical modulation of glycerolipid signaling and metabolic pathways

    PubMed Central

    Scott, Sarah A.; Mathews, Thomas P.; Ivanova, Pavlina T.; Lindsley, Craig W.; Brown, H. Alex

    2014-01-01

    Thirty years ago, glycerolipids captured the attention of biochemical researchers as novel cellular signaling entities. We now recognize that these biomolecules occupy signaling nodes critical to a number of physiological and pathological processes. Thus, glycerolipid-metabolizing enzymes present attractive targets for new therapies. A number of fields—ranging from neuroscience and cancer to diabetes and obesity—have elucidated the signaling properties of glycerolipids. The biochemical literature teems with newly emerging small molecule inhibitors capable of manipulating glycerolipid metabolism and signaling. This ever-expanding pool of chemical modulators appears daunting to those interested in exploiting glycerolipid-signaling pathways in their model system of choice. This review distills the current body of literature surrounding glycerolipid metabolism into a more approachable format, facilitating the application of small molecule inhibitors to novel systems. PMID:24440821

  6. Measurement of the intensity ratio of Auger and conversion electrons for the electron capture decay of 125I

    NASA Astrophysics Data System (ADS)

    Alotiby, M.; Greguric, I.; Kibédi, T.; Lee, B. Q.; Roberts, M.; Stuchbery, A. E.; Tee, Pi; Tornyi, T.; Vos, M.

    2018-03-01

    Auger electrons emitted after nuclear decay have potential application in targeted cancer therapy. For this purpose it is important to know the Auger electron yield per nuclear decay. In this work we describe a measurement of the ratio of the number of conversion electrons (emitted as part of the nuclear decay process) to the number of Auger electrons (emitted as part of the atomic relaxation process after the nuclear decay) for the case of 125I. Results are compared with Monte-Carlo type simulations of the relaxation cascade using the BrIccEmis code. Our results indicate that for 125I the calculations based on rates from the Evaluated Atomic Data Library underestimate the K Auger yields by 20%.

  7. [Non-pharmaceutical therapy of candidates for geriatric rehabilitation: Non-pharmaceutical therapy prescribed by SHI-accredited doctors after application for outpatient geriatric rehabilitative care].

    PubMed

    Krupp, Sonja; Schnoor, Maike; Lohse, Kristina; Katalinic, Alexander; Willkomm, Martin

    2015-06-01

    The rejection of an application for ambulant geriatric rehabilitation (AGRV) is usually justified by the argument that non-pharmaceutical therapy prescribed by doctors accredited by social housing institutions (SHI) would suffice. The reality in healthcare during the 6 months following an application is unknown. In this study 203 patients who had made an application for AGRV in the second half of 2010 in Flensburg, Lübeck or Ratzeburg were interviewed by telephone. The survey revealed that 25.7% of the applications for AGRV had been rejected. The majority of these patients received no ambulant non-pharmaceutical therapy (e.g. physical therapy, physiotherapy, occupational therapy, speech therapy or psychological therapy), less than 20% received more than 12 therapy sessions and in most cases exclusively physiotherapy. The 141 successful AGRV applicants received additional ambulant therapies of a similar magnitude. The difference between the intensified interdisciplinary therapy offered in the AGRV and additionally and the offer to rejected applicants is substantial.

  8. An Ontology of Therapies

    NASA Astrophysics Data System (ADS)

    Eccher, Claudio; Ferro, Antonella; Pisanelli, Domenico M.

    Ontologies are the essential glue to build interoperable systems and the talk of the day in the medical community. In this paper we present the ontology of medical therapies developed in the course of the Oncocure project, aimed at building a guideline based decision support integrated with a legacy Electronic Patient Record (EPR). The therapy ontology is based upon the DOLCE top level ontology. It is our opinion that our ontology, besides constituting a model capturing the precise meaning of therapy-related concepts, can serve for several practical purposes: interfacing automatic support systems with a legacy EPR, allowing the automatic data analysis, and controlling possible medical errors made during EPR data input.

  9. Rhenium-188: Availability from the W-188/Re-188 Generator and Status of Current Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pillai, M R A; Dash, A; Knapp Jr, Russ F

    Rhenium-188 is one of the most readily available generator derived and useful radionuclides for therapy emitting - particles (2.12 MeV, 71.1% and 1.965 MeV, 25.6%) and imageable gammas (155 KeV, 15.1%). The 188W/188Re generator is an ideal source for the long term (4-6 months) continuous availability of no carrier added (nca) 188Re suitable for the preparation of radiopharmaceuticals for radionuclide therapy. The challenges associated with the double neutron capture route of production of the parent 188W radionuclide have been a major impediment in the progress of application of 188Re. Tungsten-188 of adequate specific activity can be prepared only in 2-3more » of the high flux reactors operating in the World. Several useful technologies have been developed for the preparation of clinical grade 188W/188Re generator. Since the specific activity of 188W used in the generator is relatively low (<5 Ci/g), the eluted 188ReO4- can have low radioactive concentration often insufficient for radiopharmaceutical preparation. However, several efficient post elution concentration techniques have been developed that yield clinically useful 188ReO4-. Rhenium-188 has been used for the preparation of therapeutic radiopharmaceuticals for the management of diseases such as bone metastasis, rheumatoid arthritis and primary cancers. Several early phase clinical studies using radiopharmaceuticals based on 188Re-labeled phosphonates, antibodies, peptides, lipiodol and particulates have been reported. This article reviews the availability, and use of188Re including a discussion of why broader use of 188Re has not progressed as ecpected as a popular radionuclide for therapy.« less

  10. Rhenium-188: availability from the (188)W/(188)Re generator and status of current applications.

    PubMed

    Pillai, M R A; Dash, Ashutosh; Knapp, F F

    2012-07-01

    Rhenium-188 is one of the most readily available generator derived and useful radionuclides for therapy emitting β(-) particles (2.12 MeV, 71.1% and 1.965 MeV, 25.6%) and imageable gammas (155 keV, 15.1%). The (188)W/(188)Re generator is an ideal source for the long term (4-6 months) continuous availability of no carrier added (nca) (188)Re suitable for the preparation of radiopharmaceuticals for radionuclide therapy. The challenges associated with the double neutron capture route of production of the parent (188)W radionuclide have been a major impediment in the progress of application of (188)Re. Tungsten-188 of adequate specific activity can be prepared only in 2-3 of the high flux reactors operating in the World. Several useful technologies have been developed for the preparation of clinical grade (188)W/(188)Re generators. Since the specific activity of (188)W used in the generator is relatively low 185 GBq( < 5 Ci)/g], the eluted (188)ReO(4)(-) can have low radioactive concentration often insufficient for radiopharmaceutical preparation. However, several efficient post elution concentration techniques have been developed that yield clinically useful (188)ReO(4)(-) solutions. Rhenium-188 has been used for the preparation of therapeutic radiopharmaceuticals for the management of diseases such as bone metastasis, rheumatoid arthritis and primary cancers. Several early phase clinical studies using radiopharmaceuticals based on (188)Re-labeled phosphonates, antibodies, peptides, lipiodol and particulates have been reported. This article reviews the availability and use of (188)Re including a discussion of why broader use of (188)Re has not progressed as expected as a popular radionuclide for therapy.

  11. Calibration of the borated ion chamber at NIST reactor thermal column.

    PubMed

    Wang, Z; Hertel, N E; Lennox, A

    2007-01-01

    In boron neutron capture therapy and boron neutron capture enhanced fast neutron therapy, the absorbed dose of tissue due to the boron neutron capture reaction is difficult to measure directly. This dose can be computed from the measured thermal neutron fluence rate and the (10)B concentration at the site of interest. A borated tissue-equivalent (TE) ion chamber can be used to directly measure the boron dose in a phantom under irradiation by a neutron beam. Fermilab has two Exradin 0.5 cm(3) Spokas thimble TE ion chambers, one loaded with boron, available for such measurements. At the Fermilab Neutron Therapy Facility, these ion chambers are generally used with air as the filling gas. Since alpha particles and lithium ions from the (10)B(n,alpha)(7)Li reactions have very short ranges in air, the Bragg-Gray principle may not be satisfied for the borated TE ion chamber. A calibration method is described in this paper for the determination of boron capture dose using paired ion chambers. The two TE ion chambers were calibrated in the thermal column of the National Institute of Standards and Technology (NIST) research reactor. The borated TE ion chamber is loaded with 1,000 ppm of natural boron (184 ppm of (10)B). The NIST thermal column has a cadmium ratio of greater than 400 as determined by gold activation. The thermal neutron fluence rate during the calibration was determined using a NIST fission chamber to an accuracy of 5.1%. The chambers were calibrated at two different thermal neutron fluence rates: 5.11 x 10(6) and 4.46 x 10(7)n cm(-2) s(-1). The non-borated ion chamber reading was used to subtract collected charge not due to boron neutron capture reactions. An optically thick lithium slab was used to attenuate the thermal neutrons from the neutron beam port so the responses of the chambers could be corrected for fast neutrons and gamma rays in the beam. The calibration factor of the borated ion chamber was determined to be 1.83 x 10(9) +/- 5.5% (+/- 1sigma) n cm(-2) per nC at standard temperature and pressure condition.

  12. Polysulfide intercalated layered double hydroxides for metal capture applications

    DOEpatents

    Kanatzidis, Mercouri G.; Ma, Shulan

    2017-04-04

    Polysulfide intercalated layered double hydroxides and methods for their use in vapor and liquid-phase metal capture applications are provided. The layered double hydroxides comprise a plurality of positively charged host layers of mixed metal hydroxides separated by interlayer spaces. Polysulfide anions are intercalated in the interlayer spaces.

  13. 77 FR 29357 - Endangered and Threatened Wildlife and Plants; Permit Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-17

    ... History Survey, Champaign, IL. The applicant requests a permit to take (capture and release; capture and...). Proposed activities would occur throughout the State of Illinois, including presence/absence surveys and... utilizing an experimental design to determine susceptibility of bats to turbine mortality at varying wind...

  14. MCNP simulation of the dose distribution in liver cancer treatment for BNC therapy

    NASA Astrophysics Data System (ADS)

    Krstic, Dragana; Jovanovic, Zoran; Markovic, Vladimir; Nikezic, Dragoslav; Urosevic, Vlade

    2014-10-01

    The Boron Neutron Capture Therapy ( BNCT) is based on selective uptake of boron in tumour tissue compared to the surrounding normal tissue. Infusion of compounds with boron is followed by irradiation with neutrons. Neutron capture on 10B, which gives rise to an alpha particle and recoiled 7Li ion, enables the therapeutic dose to be delivered to tumour tissue while healthy tissue can be spared. Here, therapeutic abilities of BNCT were studied for possible treatment of liver cancer using thermal and epithermal neutron beam. For neutron transport MCNP software was used and doses in organs of interest in ORNL phantom were evaluated. Phantom organs were filled with voxels in order to obtain depth-dose distributions in them. The result suggests that BNCT using an epithermal neutron beam could be applied for liver cancer treatment.

  15. Human radiation studies: Remembering the early years: Oral history of physician James S. Robertson, M.D., Ph.D., conducted January 20, 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-09-01

    This report is a transcript of in interview of Dr. James S. Robertson by representatives of the DOE Office of Human Radiation Experiments. Dr. Robertson was chosen for this interview because of his research at Brookhaven National Laboratory, especially on Boron Neutron Capture Therapy (BNCT); his work at the United States Naval Defense Laboratory; and his work at the Atomic Energy Commission. After a brief biographical sketch Dr. Robertson discusses research on human subjects at Berkeley, his contributions to the beginnings of Neutron Capture Therapy at Brookhaven, his participation with the Brookhaven Human Use Committee, his involvement in the studymore » of the effects of Castle Bravo event on the Marshallese, and his work with the Naval Radiological Defense Laboratory.« less

  16. A Versatile Microarray Platform for Capturing Rare Cells

    NASA Astrophysics Data System (ADS)

    Brinkmann, Falko; Hirtz, Michael; Haller, Anna; Gorges, Tobias M.; Vellekoop, Michael J.; Riethdorf, Sabine; Müller, Volkmar; Pantel, Klaus; Fuchs, Harald

    2015-10-01

    Analyses of rare events occurring at extremely low frequencies in body fluids are still challenging. We established a versatile microarray-based platform able to capture single target cells from large background populations. As use case we chose the challenging application of detecting circulating tumor cells (CTCs) - about one cell in a billion normal blood cells. After incubation with an antibody cocktail, targeted cells are extracted on a microarray in a microfluidic chip. The accessibility of our platform allows for subsequent recovery of targets for further analysis. The microarray facilitates exclusion of false positive capture events by co-localization allowing for detection without fluorescent labelling. Analyzing blood samples from cancer patients with our platform reached and partly outreached gold standard performance, demonstrating feasibility for clinical application. Clinical researchers free choice of antibody cocktail without need for altered chip manufacturing or incubation protocol, allows virtual arbitrary targeting of capture species and therefore wide spread applications in biomedical sciences.

  17. Intrathecal baclofen therapy in paediatrics: a study protocol for an Australian multicentre, 10-year prospective audit

    PubMed Central

    Stewart, Kirsty; Hutana, Gavin; Kentish, Megan

    2017-01-01

    Introduction Increasing clinical use of Intrathecal baclofen (ITB) in Australian tertiary paediatric hospitals, along with the need for standardised assessment and reporting of adverse events, saw the formation of the Australian Paediatric ITB Research Group (APIRG). APIRG developed a National ITB Audit tool designed to capture clinical outcomes and adverse events data for all Australian children and adolescents receiving ITB therapy. Methods and analysis The Australian ITB Audit is a 10 year, longitudinal, prospective, clinical audit collecting all adverse events and assessment data across body functions and structure, participation and activity level domains of the ICF. Data will be collected at baseline, 6 and 12 months with ongoing capture of all adverse event data. This is the first Australian study that aims to capture clinical and adverse event data from a complete population of children with neurological impairment receiving a specific intervention between 2011 and 2021. This multi-centre study will inform ITB clinical practice in children and adolescents, direct patient selection, record and aid decision making regarding adverse events and investigate the impact of ITB therapy on family and patient quality of life. Ethics and dissemination This project was approved by the individual Human Research Ethics committees at the six Australian tertiary hospitals involved in the study. Results will be published in various peer reviewed journals and presented at national and international conferences. Trial registration number ACTRN 12610000323022; Pre-results. PMID:28637739

  18. A theranostic approach based on the use of a dual boron/Gd agent to improve the efficacy of Boron Neutron Capture Therapy in the lung cancer treatment.

    PubMed

    Alberti, Diego; Protti, Nicoletta; Toppino, Antonio; Deagostino, Annamaria; Lanzardo, Stefania; Bortolussi, Silva; Altieri, Saverio; Voena, Claudia; Chiarle, Roberto; Geninatti Crich, Simonetta; Aime, Silvio

    2015-04-01

    This study aims at developing an innovative theranostic approach for lung tumor and metastases treatment, based on Boron Neutron Capture Therapy (BNCT). It relies on to the use of low density lipoproteins (LDL) as carriers able to maximize the selective uptake of boron atoms in tumor cells and, at the same time, to quantify the in vivo boron distribution by magnetic resonance imaging (MRI). Tumor cells uptake was initially assessed by ICP-MS and MRI on four types of tumor (TUBO, B16-F10, MCF-7, A549) and one healthy (N-MUG) cell lines. Lung metastases were generated by intravenous injection of a Her2+ breast cancer cell line (i.e. TUBO) in BALB/c mice and transgenic EML4-ALK mice were used as primary tumor model. After neutron irradiation, tumor growth was followed for 30-40 days by MRI. Tumor masses of boron treated mice increased markedly slowly than the control group. From the clinical editor: In this article, the authors described an improvement to existing boron neutron capture therapy. The dual MRI/BNCT agent, carried by LDLs, was able to maximize the selective uptake of boron in tumor cells, and, at the same time, quantify boron distribution in tumor and in other tissues using MRI. Subsequent in vitro and in vivo experiments showed tumor cell killing after neutron irradiation. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Novel Hyaluronan Formulation Enhances the Efficacy of Boron Neutron Capture Therapy for Murine Mesothelioma.

    PubMed

    Sasai, Masao; Nakamura, Hiroyuki; Sougawa, Nagako; Sakurai, Yoshinori; Suzuki, Minoru; Lee, Chun Man

    2016-03-01

    Malignant pleural mesothelioma (MPM) is a refractory cancer of the pleura caused by asbestos exposure. MPM is difficult to treat because it easily disseminates. Boron neutron capture therapy (BNCT) is a radiotherapy in which cancer cells that selectively take up (10)Boron-containing compounds are destroyed, and normal cells are uninjured. Hyaluronan (HA) is a ligand of cluster of differentiation 44 (CD44), that is expressed on MPM cells. In order to enhance BNCT for MPM tumors, we developed a novel HA-containing (10)B (sodium borocaptate: BSH) formulation (HA-BND-S). We examined the efficacy of HA-BND-S using MPM cells and a mouse MPM model. HA-BND-S preferentially bound MPM cells dose-dependently, and increased the cytotoxicity of BNCT compared to BSH in vitro. HA-BND-S administration significantly increased the survival of MPM tumor-bearing mice compared to BSH at the same (10)B dosage in BNCT. Modifying BSH with HA is a promising strategy for enhancing the efficacy of BNCT for therapy of MPM. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  20. Boron neutron capture therapy demonstrated in mice bearing EMT6 tumors following selective delivery of boron by rationally designed liposomes

    PubMed Central

    Kueffer, Peter J.; Maitz, Charles A.; Khan, Aslam A.; Schuster, Seth A.; Shlyakhtina, Natalia I.; Jalisatgi, Satish S.; Brockman, John D.; Nigg, David W.; Hawthorne, M. Frederick

    2013-01-01

    The application of boron neutron capture therapy (BNCT) following liposomal delivery of a 10B-enriched polyhedral borane and a carborane against mouse mammary adenocarcinoma solid tumors was investigated. Unilamellar liposomes with a mean diameter of 134 nm or less, composed of an equimolar mixture of cholesterol and 1,2-distearoyl-sn-glycero-3-phosphocholine and incorporating Na3[1-(2′-B10H9)-2-NH3B10H8] in the aqueous interior and K[nido-7-CH3(CH2)15-7,8-C2B9H11] in the bilayer, were injected into the tail veins of female BALB/c mice bearing right flank EMT6 tumors. Biodistribution studies indicated that two identical injections given 24 h apart resulted in tumor boron levels exceeding 67 µg/g tumor at 54 h—with tumor/blood boron ratios being greatest at 96 h (5.68:1; 43 µg boron/g tumor)—following the initial injection. For BNCT experiments, tumor-bearing mice were irradiated 54 h after the initial injection for 30 min with thermal neutrons, resulting in a total fluence of 1.6 × 1012 neutrons per cm2 (±7%). Significant suppression of tumor growth was observed in mice given BNCT vs. control mice (only 424% increase in tumor volume at 14 d post irradiation vs. 1551% in untreated controls). In a separate experiment in which mice were given a second injection/irradiation treatment 7 d after the first, the tumor growth was vastly diminished (186% tumor volume increase at 14 d). A similar response was obtained for mice irradiated for 60 min (169% increase at 14 d), suggesting that neutron fluence was the limiting factor controlling BNCT efficacy in this study. PMID:23536304

  1. Therapeutic efficacy of boron neutron capture therapy mediated by boron-rich liposomes for oral cancer in the hamster cheek pouch model.

    PubMed

    Heber, Elisa M; Hawthorne, M Frederick; Kueffer, Peter J; Garabalino, Marcela A; Thorp, Silvia I; Pozzi, Emiliano C C; Monti Hughes, Andrea; Maitz, Charles A; Jalisatgi, Satish S; Nigg, David W; Curotto, Paula; Trivillin, Verónica A; Schwint, Amanda E

    2014-11-11

    The application of boron neutron capture therapy (BNCT) mediated by liposomes containing (10)B-enriched polyhedral borane and carborane derivatives for the treatment of head and neck cancer in the hamster cheek pouch oral cancer model is presented. These liposomes are composed of an equimolar ratio of cholesterol and 1,2-distearoyl-sn-glycero-3-phosphocholine, incorporating K[nido-7-CH3(CH2)15-7,8-C2B9H11] (MAC) in the bilayer membrane while encapsulating the hydrophilic species Na3[ae-B20H17NH3] (TAC) in the aqueous core. Unilamellar liposomes with a mean diameter of 83 nm were administered i.v. in hamsters. After 48 h, the boron concentration in tumors was 67 ± 16 ppm whereas the precancerous tissue contained 11 ± 6 ppm, and the tumor/normal pouch tissue boron concentration ratio was 10:1. Neutron irradiation giving a 5-Gy dose to precancerous tissue (corresponding to 21 Gy in tumor) resulted in an overall tumor response (OR) of 70% after a 4-wk posttreatment period. In contrast, the beam-only protocol gave an OR rate of only 28%. Once-repeated BNCT treatment with readministration of liposomes at an interval of 4, 6, or 8 wk resulted in OR rates of 70-88%, of which the complete response ranged from 37% to 52%. Because of the good therapeutic outcome, it was possible to extend the follow-up of BNCT treatment groups to 16 wk after the first treatment. No radiotoxicity to normal tissue was observed. A salient advantage of these liposomes was that only mild mucositis was observed in dose-limiting precancerous tissue with a sustained tumor response of 70-88%.

  2. Therapeutic efficacy of boron neutron capture therapy mediated by boron-rich liposomes for oral cancer in the hamster cheek pouch model

    PubMed Central

    Heber, Elisa M.; Hawthorne, M. Frederick; Kueffer, Peter J.; Garabalino, Marcela A.; Thorp, Silvia I.; Pozzi, Emiliano C. C.; Hughes, Andrea Monti; Maitz, Charles A.; Jalisatgi, Satish S.; Nigg, David W.; Curotto, Paula; Trivillin, Verónica A.; Schwint, Amanda E.

    2014-01-01

    The application of boron neutron capture therapy (BNCT) mediated by liposomes containing 10B-enriched polyhedral borane and carborane derivatives for the treatment of head and neck cancer in the hamster cheek pouch oral cancer model is presented. These liposomes are composed of an equimolar ratio of cholesterol and 1,2-distearoyl-sn-glycero-3-phosphocholine, incorporating K[nido-7-CH3(CH2)15-7,8-C2B9H11] (MAC) in the bilayer membrane while encapsulating the hydrophilic species Na3[ae-B20H17NH3] (TAC) in the aqueous core. Unilamellar liposomes with a mean diameter of 83 nm were administered i.v. in hamsters. After 48 h, the boron concentration in tumors was 67 ± 16 ppm whereas the precancerous tissue contained 11 ± 6 ppm, and the tumor/normal pouch tissue boron concentration ratio was 10:1. Neutron irradiation giving a 5-Gy dose to precancerous tissue (corresponding to 21 Gy in tumor) resulted in an overall tumor response (OR) of 70% after a 4-wk posttreatment period. In contrast, the beam-only protocol gave an OR rate of only 28%. Once-repeated BNCT treatment with readministration of liposomes at an interval of 4, 6, or 8 wk resulted in OR rates of 70–88%, of which the complete response ranged from 37% to 52%. Because of the good therapeutic outcome, it was possible to extend the follow-up of BNCT treatment groups to 16 wk after the first treatment. No radiotoxicity to normal tissue was observed. A salient advantage of these liposomes was that only mild mucositis was observed in dose-limiting precancerous tissue with a sustained tumor response of 70–88%. PMID:25349432

  3. Influence of Neutron Sources and 10B Concentration on Boron Neutron Capture Therapy for Shallow and Deeper Non-small Cell Lung Cancer.

    PubMed

    Yu, Haiyan; Tang, Xiaobin; Shu, Diyun; Liu, Yuanhao; Geng, Changran; Gong, Chunhui; Hang, Shuang; Chen, Da

    2017-03-01

    Boron Neutron Capture Therapy (BNCT) is a radiotherapy that combines biological targeting and high Linear Energy Transfer (LET). It is considered a potential therapeutic approach for non-small cell lung cancer (NSCLC). It could avoid the inaccurate treatment caused by the lung motion during radiotherapy, because the dose deposition mainly depends on the boron localization and neutron source. Thus, B concentration and neutron sources are both principal factors of BNCT, and they play significant roles in the curative effect of BNCT for different cases. The purpose was to explore the feasibility of BNCT treatment for NSCLC with either of two neutron sources (the epithermal reactor at the Massachusetts Institute of Technology named "MIT source" and the accelerator neutron source designed in Argentina named "MEC source") and various boron concentrations. Shallow and deeper lung tumors were defined in the Chinese hybrid radiation phantom, and the Monte Carlo method was used to calculate the dose to tumors and healthy organs. The MEC source was more appropriate to treat the shallow tumor (depth of 6 cm) with a shorter treatment time. However, the MIT source was more suitable for deep lung tumor (depth of 9 cm) treatment, as the MEC source is more likely to exceed the skin dose limit. Thus, a neutron source consisting of more fast neutrons is not necessarily suitable for deep treatment of lung tumors. Theoretical distribution of B in tumors and organs at risk (especially skin) was obtained to meet the treatable requirement of BNCT, which may provide the references to identify the feasibility of BNCT for the treatment of lung cancer using these two neutron sources in future clinical applications.

  4. Overview of the High Performance Antiproton Trap (HiPAT) Experiment

    NASA Technical Reports Server (NTRS)

    Martin, James; Chakrabarti, Suman; Pearson, Boise; Sims, W. Herbert; Lewis, Raymond; Fant, Wallace; Rodgers, Stephen (Technical Monitor)

    2002-01-01

    A general overview of the High Performance Antiproton Trap (HiPAT) Experiment is presented. The topics include: 1) Why Antimatter? 2) HiPAT Applicability; 3) Approach-Goals; 4) HiPAT General Layout; 5) Sizing For Containment; 6) Laboratory Operations; 7) Vacuum System Cleaning; 8) Ion Production Via Electron Gun; 9) Particle Capture Via Ion Sources; 10) Ion Beam Steering/Focusing; 11) Ideal Ion Stacking Sequence; 12) Setup For Dynamic Capture; 13) Dynamic Capture of H(+) Ions; 14) Dynamic Capture; 15) Radio Frequency Particle Detection; 16) Radio Frequency Antenna Modeling; and 17) R.F. Stabilization-Low Frequencies. A short presentation of propulsion applications of Antimatter is also given. This paper is in viewgraph form.

  5. Source Update Capture in Information Agents

    NASA Technical Reports Server (NTRS)

    Ashish, Naveen; Kulkarni, Deepak; Wang, Yao

    2003-01-01

    In this paper we present strategies for successfully capturing updates at Web sources. Web-based information agents provide integrated access to autonomous Web sources that can get updated. For many information agent applications we are interested in knowing when a Web source to which the application provides access, has been updated. We may also be interested in capturing all the updates at a Web source over a period of time i.e., detecting the updates and, for each update retrieving and storing the new version of data. Previous work on update and change detection by polling does not adequately address this problem. We present strategies for intelligently polling a Web source for efficiently capturing changes at the source.

  6. L-Phenylalanine preloading reduces the (10)B(n, α)(7)Li dose to the normal brain by inhibiting the uptake of boronophenylalanine in boron neutron capture therapy for brain tumours.

    PubMed

    Watanabe, Tsubasa; Tanaka, Hiroki; Fukutani, Satoshi; Suzuki, Minoru; Hiraoka, Masahiro; Ono, Koji

    2016-01-01

    Boron neutron capture therapy (BNCT) is a cellular-level particle radiation therapy that combines the selective delivery of boron compounds to tumour tissue with neutron irradiation. Previously, high doses of one of the boron compounds used for BNCT, L-BPA, were found to reduce the boron-derived irradiation dose to the central nervous system. However, injection with a high dose of L-BPA is not feasible in clinical settings. We aimed to find an alternative method to improve the therapeutic efficacy of this therapy. We examined the effects of oral preloading with various analogues of L-BPA in a xenograft tumour model and found that high-dose L-phenylalanine reduced the accumulation of L-BPA in the normal brain relative to tumour tissue. As a result, the maximum irradiation dose in the normal brain was 19.2% lower in the L-phenylalanine group relative to the control group. This study provides a simple strategy to improve the therapeutic efficacy of conventional boron compounds for BNCT for brain tumours and the possibility to widen the indication of BNCT to various kinds of other tumours. Copyright © 2015. Published by Elsevier Ireland Ltd.

  7. Effective capture and release of circulating tumor cells using core-shell Fe3O4@MnO2 nanoparticles

    NASA Astrophysics Data System (ADS)

    Xiao, Liang; He, Zhao-Bo; Cai, Bo; Rao, Lang; Cheng, Long; Liu, Wei; Guo, Shi-Shang; Zhao, Xing-Zhong

    2017-01-01

    Circulating tumor cells (CTCs) have been believed to hold significant insights for cancer diagnosis and therapy. Here, we developed a simple and effective method to capture and release viable CTCs using core-shell Fe3O4@MnO2 nanoparticles. Fe3O4@MnO2 nanoparticles bioconjugated with anti-EpCAM antibody have characteristics of specific recognition, magnetic-driven cell isolation and oxalic acid-assisted cell release. The capture and release efficiency of target cancer cells were ∼83% and ∼55%, respectively. And ∼70% of released cells kept good viability, which could facilitate the subsequent cellular analysis.

  8. Hydrodynamic Capture and Release of Passively Driven Particles by Active Particles Under Hele-Shaw Flows

    NASA Astrophysics Data System (ADS)

    Mishler, Grant; Tsang, Alan Cheng Hou; Pak, On Shun

    2018-03-01

    The transport of active and passive particles plays central roles in diverse biological phenomena and engineering applications. In this paper, we present a theoretical investigation of a system consisting of an active particle and a passive particle in a confined micro-fluidic flow. The introduction of an external flow is found to induce the capture of the passive particle by the active particle via long-range hydrodynamic interactions among the particles. This hydrodynamic capture mechanism relies on an attracting stable equilibrium configuration formed by the particles, which occurs when the external flow intensity exceeds a certain threshold. We evaluate this threshold by studying the stability of the equilibrium configurations analytically and numerically. Furthermore, we study the dynamics of typical capture and non-capture events and characterize the basins of attraction of the equilibrium configurations. Our findings reveal a critical dependence of the hydrodynamic capture mechanism on the external flow intensity. Through adjusting the external flow intensity across the stability threshold, we demonstrate that the active particle can capture and release the passive particle in a controllable manner. Such a capture-and-release mechanism is desirable for biomedical applications such as the capture and release of therapeutic payloads by synthetic micro-swimmers in targeted drug delivery.

  9. Computational prediction of multidisciplinary team decision-making for adjuvant breast cancer drug therapies: a machine learning approach.

    PubMed

    Lin, Frank P Y; Pokorny, Adrian; Teng, Christina; Dear, Rachel; Epstein, Richard J

    2016-12-01

    Multidisciplinary team (MDT) meetings are used to optimise expert decision-making about treatment options, but such expertise is not digitally transferable between centres. To help standardise medical decision-making, we developed a machine learning model designed to predict MDT decisions about adjuvant breast cancer treatments. We analysed MDT decisions regarding adjuvant systemic therapy for 1065 breast cancer cases over eight years. Machine learning classifiers with and without bootstrap aggregation were correlated with MDT decisions (recommended, not recommended, or discussable) regarding adjuvant cytotoxic, endocrine and biologic/targeted therapies, then tested for predictability using stratified ten-fold cross-validations. The predictions so derived were duly compared with those based on published (ESMO and NCCN) cancer guidelines. Machine learning more accurately predicted adjuvant chemotherapy MDT decisions than did simple application of guidelines. No differences were found between MDT- vs. ESMO/NCCN- based decisions to prescribe either adjuvant endocrine (97%, p = 0.44/0.74) or biologic/targeted therapies (98%, p = 0.82/0.59). In contrast, significant discrepancies were evident between MDT- and guideline-based decisions to prescribe chemotherapy (87%, p < 0.01, representing 43% and 53% variations from ESMO/NCCN guidelines, respectively). Using ten-fold cross-validation, the best classifiers achieved areas under the receiver operating characteristic curve (AUC) of 0.940 for chemotherapy (95% C.I., 0.922-0.958), 0.899 for the endocrine therapy (95% C.I., 0.880-0.918), and 0.977 for trastuzumab therapy (95% C.I., 0.955-0.999) respectively. Overall, bootstrap aggregated classifiers performed better among all evaluated machine learning models. A machine learning approach based on clinicopathologic characteristics can predict MDT decisions about adjuvant breast cancer drug therapies. The discrepancy between MDT- and guideline-based decisions regarding adjuvant chemotherapy implies that certain non-clincopathologic criteria, such as patient preference and resource availability, are factored into clinical decision-making by local experts but not captured by guidelines.

  10. Experimental Studies of Boronophenylalanine ({sup 10}BPA) Biodistribution for the Individual Application of Boron Neutron Capture Therapy (BNCT) for Malignant Melanoma Treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carpano, Marina; Perona, Marina; Rodriguez, Carla

    Purpose: Patients with the same histopathologic diagnosis of cutaneous melanoma treated with identical protocols of boron neutron capture therapy (BNCT) have shown different clinical outcomes. The objective of the present studies was to evaluate the biodistribution of boronophenilalanina ({sup 10}BPA) for the potential application of BNCT for the treatment of melanoma on an individual basis. Methods and Materials: The boronophenilalanine (BPA) uptake was evaluated in 3 human melanoma cell lines: MEL-J, A375, and M8. NIH nude mice were implanted with 4 10{sup 6} MEL-J cells, and biodistribution studies of BPA (350 mg/kg intraperitoneally) were performed. Static infrared imaging using a speciallymore » modified infrared camera adapted to measure the body infrared radiance of small animals was used. Proliferation marker, Ki-67, and endothelial marker, CD31, were analyzed in tumor samples. Results: The in vitro studies demonstrated different patterns of BPA uptake for each analyzed cell line (P<.001 for MEL-J and A375 vs M8 cells). The in vivo studies showed a maximum average boron concentration of 25.9 ± 2.6 μg/g in tumor, with individual values ranging between 11.7 and 52.0 μg/g of {sup 10}B 2 hours after the injection of BPA. Tumor temperature always decreased as the tumors increased in size, with values ranging between 37°C and 23°C. A significant correlation between tumor temperature and tumor-to-blood boron concentration ratio was found (R{sup 2} = 0.7, rational function fit). The immunohistochemical studies revealed, in tumors with extensive areas of viability, a high number of positive cells for Ki-67, blood vessels of large diameter evidenced by the marker CD31, and a direct logistic correlation between proliferative status and boron concentration difference between tumor and blood (R{sup 2} = 0.81, logistic function fit). Conclusion: We propose that these methods could be suitable for designing new screening protocols applied before melanoma BNCT treatment for each individual patient and lesion.« less

  11. Experimental Studies of Boronophenylalanine ((10)BPA) Biodistribution for the Individual Application of Boron Neutron Capture Therapy (BNCT) for Malignant Melanoma Treatment.

    PubMed

    Carpano, Marina; Perona, Marina; Rodriguez, Carla; Nievas, Susana; Olivera, Maria; Santa Cruz, Gustavo A; Brandizzi, Daniel; Cabrini, Romulo; Pisarev, Mario; Juvenal, Guillermo Juan; Dagrosa, Maria Alejandra

    2015-10-01

    Patients with the same histopathologic diagnosis of cutaneous melanoma treated with identical protocols of boron neutron capture therapy (BNCT) have shown different clinical outcomes. The objective of the present studies was to evaluate the biodistribution of boronophenilalanina ((10)BPA) for the potential application of BNCT for the treatment of melanoma on an individual basis. The boronophenilalanine (BPA) uptake was evaluated in 3 human melanoma cell lines: MEL-J, A375, and M8. NIH nude mice were implanted with 4 10(6) MEL-J cells, and biodistribution studies of BPA (350 mg/kg intraperitoneally) were performed. Static infrared imaging using a specially modified infrared camera adapted to measure the body infrared radiance of small animals was used. Proliferation marker, Ki-67, and endothelial marker, CD31, were analyzed in tumor samples. The in vitro studies demonstrated different patterns of BPA uptake for each analyzed cell line (P<.001 for MEL-J and A375 vs M8 cells). The in vivo studies showed a maximum average boron concentration of 25.9 ± 2.6 μg/g in tumor, with individual values ranging between 11.7 and 52.0 μg/g of (10)B 2 hours after the injection of BPA. Tumor temperature always decreased as the tumors increased in size, with values ranging between 37 °C and 23 °C. A significant correlation between tumor temperature and tumor-to-blood boron concentration ratio was found (R(2) = 0.7, rational function fit). The immunohistochemical studies revealed, in tumors with extensive areas of viability, a high number of positive cells for Ki-67, blood vessels of large diameter evidenced by the marker CD31, and a direct logistic correlation between proliferative status and boron concentration difference between tumor and blood (R(2) = 0.81, logistic function fit). We propose that these methods could be suitable for designing new screening protocols applied before melanoma BNCT treatment for each individual patient and lesion. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Photon iso-effective dose for cancer treatment with mixed field radiation based on dose-response assessment from human and an animal model: clinical application to boron neutron capture therapy for head and neck cancer

    NASA Astrophysics Data System (ADS)

    González, S. J.; Pozzi, E. C. C.; Monti Hughes, A.; Provenzano, L.; Koivunoro, H.; Carando, D. G.; Thorp, S. I.; Casal, M. R.; Bortolussi, S.; Trivillin, V. A.; Garabalino, M. A.; Curotto, P.; Heber, E. M.; Santa Cruz, G. A.; Kankaanranta, L.; Joensuu, H.; Schwint, A. E.

    2017-10-01

    Boron neutron capture therapy (BNCT) is a treatment modality that combines different radiation qualities. Since the severity of biological damage following irradiation depends on the radiation type, a quantity different from absorbed dose is required to explain the effects observed in the clinical BNCT in terms of outcome compared with conventional photon radiation therapy. A new approach for calculating photon iso-effective doses in BNCT was introduced previously. The present work extends this model to include information from dose-response assessments in animal models and humans. Parameters of the model were determined for tumour and precancerous tissue using dose-response curves obtained from BNCT and photon studies performed in the hamster cheek pouch in vivo models of oral cancer and/or pre-cancer, and from head and neck cancer radiotherapy data with photons. To this end, suitable expressions of the dose-limiting Normal Tissue Complication and Tumour Control Probabilities for the reference radiation and for the mixed field BNCT radiation were developed. Pearson’s correlation coefficients and p-values showed that TCP and NTCP models agreed with experimental data (with r  >  0.87 and p-values  >0.57). The photon iso-effective dose model was applied retrospectively to evaluate the dosimetry in tumours and mucosa for head and neck cancer patients treated with BNCT in Finland. Photon iso-effective doses in tumour were lower than those obtained with the standard RBE-weighted model (between 10% to 45%). The results also suggested that the probabilities of tumour control derived from photon iso-effective doses are more adequate to explain the clinical responses than those obtained with the RBE-weighted values. The dosimetry in the mucosa revealed that the photon iso-effective doses were about 30% to 50% higher than the corresponding RBE-weighted values. While the RBE-weighted doses are unable to predict mucosa toxicity, predictions based on the proposed model are compatible with the observed clinical outcome. The extension of the photon iso-effective dose model has allowed, for the first time, the determination of the photon iso-effective dose for unacceptable complications in the dose-limiting normal tissue. Finally, the formalism developed in this work to compute photon-equivalent doses can be applied to other therapies that combine mixed radiation fields, such as hadron therapy.

  13. Photon iso-effective dose for cancer treatment with mixed field radiation based on dose-response assessment from human and an animal model: clinical application to boron neutron capture therapy for head and neck cancer.

    PubMed

    González, S J; Pozzi, E C C; Monti Hughes, A; Provenzano, L; Koivunoro, H; Carando, D G; Thorp, S I; Casal, M R; Bortolussi, S; Trivillin, V A; Garabalino, M A; Curotto, P; Heber, E M; Santa Cruz, G A; Kankaanranta, L; Joensuu, H; Schwint, A E

    2017-10-03

    Boron neutron capture therapy (BNCT) is a treatment modality that combines different radiation qualities. Since the severity of biological damage following irradiation depends on the radiation type, a quantity different from absorbed dose is required to explain the effects observed in the clinical BNCT in terms of outcome compared with conventional photon radiation therapy. A new approach for calculating photon iso-effective doses in BNCT was introduced previously. The present work extends this model to include information from dose-response assessments in animal models and humans. Parameters of the model were determined for tumour and precancerous tissue using dose-response curves obtained from BNCT and photon studies performed in the hamster cheek pouch in vivo models of oral cancer and/or pre-cancer, and from head and neck cancer radiotherapy data with photons. To this end, suitable expressions of the dose-limiting Normal Tissue Complication and Tumour Control Probabilities for the reference radiation and for the mixed field BNCT radiation were developed. Pearson's correlation coefficients and p-values showed that TCP and NTCP models agreed with experimental data (with r  >  0.87 and p-values  >0.57). The photon iso-effective dose model was applied retrospectively to evaluate the dosimetry in tumours and mucosa for head and neck cancer patients treated with BNCT in Finland. Photon iso-effective doses in tumour were lower than those obtained with the standard RBE-weighted model (between 10% to 45%). The results also suggested that the probabilities of tumour control derived from photon iso-effective doses are more adequate to explain the clinical responses than those obtained with the RBE-weighted values. The dosimetry in the mucosa revealed that the photon iso-effective doses were about 30% to 50% higher than the corresponding RBE-weighted values. While the RBE-weighted doses are unable to predict mucosa toxicity, predictions based on the proposed model are compatible with the observed clinical outcome. The extension of the photon iso-effective dose model has allowed, for the first time, the determination of the photon iso-effective dose for unacceptable complications in the dose-limiting normal tissue. Finally, the formalism developed in this work to compute photon-equivalent doses can be applied to other therapies that combine mixed radiation fields, such as hadron therapy.

  14. TREatment of ATopic eczema (TREAT) Registry Taskforce: protocol for an international Delphi exercise to identify a core set of domains and domain items for national atopic eczema registries.

    PubMed

    Gerbens, Louise A A; Boyce, Aaron E; Wall, Dmitri; Barbarot, Sebastien; de Booij, Richard J; Deleuran, Mette; Middelkamp-Hup, Maritza A; Roberts, Amanda; Vestergaard, Christian; Weidinger, Stephan; Apfelbacher, Christian J; Irvine, Alan D; Schmitt, Jochen; Williamson, Paula R; Spuls, Phyllis I; Flohr, Carsten

    2017-02-27

    Patients with moderate-to-severe atopic eczema (AE) often require photo- or systemic immunomodulatory therapies to induce disease remission and maintain long-term control. The current evidence to guide clinical management is small, despite the frequent and often off-label use of these treatments. Registries of patients on photo- and systemic immunomodulatory therapies could fill this gap, and the collection of a core set concerning these therapies in AE will allow direct comparisons across registries as well as data sharing and pooling. Using an eDelphi approach, the international TREatment of ATopic eczema (TREAT) Registry Taskforce aims to seek consensus between key stakeholders internationally on a core set of domains and domain items for AE patient registries with a research focus that collect data of children and adults on photo- and systemic immunomodulatory therapies. Participants from six stakeholder groups will be invited: doctors, nurses, non-clinical researchers, patients, as well as industry and regulatory body representatives. The eDelphi will comprise three sequential online rounds, requesting participants to rate the importance of each proposed domain and domain items. Participants will be able to add domains and domain items to the proposed list in round 1. A final consensus meeting will be held with representatives of each stakeholder group. Identifying a uniform core set of domains and domain items to be captured by AE patient registries will increase the utility of individual registries, and provide greater insight into the effectiveness, safety and cost-effectiveness of photo- and systemic immunomodulatory therapies to guide clinical management across dermatology centres and country borders. Not applicable. This eDelphi study was registered in the Core Outcome Measures for Effectiveness Trials (COMET) database.

  15. Design and Kinematic Evaluation of a Novel Joint-Specific Play Controller: Application for Wrist and Forearm Therapy

    PubMed Central

    Schwartz, Joel B.; Wilcox, Bethany; Costa, Laura; Kerman, Karen

    2015-01-01

    Background The wrist extensors and flexors are profoundly affected in most children with hemiparetic cerebral palsy (CP) and are the major target of physical therapists' and occupational therapists' efforts to restore useful hand functions. A limitation of any therapeutic or exercise program can be the level of the child's engagement or adherence. The proposed approach capitalizes on the primary learning avenue for children: toy play. Objective This study aimed to develop and evaluate the measurement accuracy of innovative, motion-specific play controllers that are engaging rehabilitative devices for enhancing therapy and promoting neural plasticity and functional recovery in children with CP. Design Design objectives of the play controller included a cost-effective, home-based supplement to physical therapy, the ability to calibrate the controller so that play can be accomplished with any active range of motion, and the capability of logging play activity and wrist motion over week-long periods. Methods Accuracy of the play controller in measuring wrist flexion-extension was evaluated in 6 children who were developing in a typical manner, using optical motion capture of the wrist and forearm as the gold standard. Results The error of the play controller was estimated at approximately 5 degrees in both maximum wrist flexion and extension. Limitations Measurements were taken during a laboratory session, with children without CP, and no toy or computer game was interfaced with the play controller. Therefore, the potential engagement of the proposed approach for therapy remains to be evaluated. Conclusions This study presented the concept, development, and wrist tracking accuracy of an inexpensive approach to extremity therapy that may have a health benefit for children with hemiparesis, and potentially for patients of any age with a wide range of extremity neuromotor impairments. PMID:25573759

  16. Apoptosis through Bcl-2/Bax and Cleaved Caspase Up-Regulation in Melanoma Treated by Boron Neutron Capture Therapy

    PubMed Central

    Faião-Flores, Fernanda; Coelho, Paulo Rogério Pinto; Toledo Arruda-Neto, João Dias; Maria-Engler, Silvya Stuchi; Tiago, Manoela; Capelozzi, Vera Luiza; Giorgi, Ricardo Rodrigues; Maria, Durvanei Augusto

    2013-01-01

    Boron neutron capture therapy (BNCT) is a binary treatment involving selective accumulation of boron carriers in a tumor followed by irradiation with a thermal or epithermal neutron beam. The neutron capture reaction with a boron-10 nucleus yields high linear energy transfer (LET) particles, alpha and 7Li, with a range of 5 to 9 µm. These particles can only travel very short distances and release their damaging energy directly into the cells containing the boron compound. We aimed to evaluate proliferation, apoptosis and extracellular matrix (ECM) modifications of B16F10 melanoma and normal human melanocytes after BNCT. The amounts of soluble collagen and Hsp47, indicating collagen synthesis in the ECM, as well as the cellular markers of apoptosis, were investigated. BNCT decreased proliferation, altered the ECM by decreasing collagen synthesis and induced apoptosis by regulating Bcl-2/Bax in melanoma. Additionally, BNCT also increased the levels of TNF receptor and the cleaved caspases 3, 7, 8 and 9 in melanoma. These results suggest that multiple pathways related to cell death and cell cycle arrest are involved in the treatment of melanoma by BNCT. PMID:23527236

  17. A light-weight compact proton gantry design with a novel dose delivery system for broad-energetic laser-accelerated beams

    NASA Astrophysics Data System (ADS)

    Masood, U.; Cowan, T. E.; Enghardt, W.; Hofmann, K. M.; Karsch, L.; Kroll, F.; Schramm, U.; Wilkens, J. J.; Pawelke, J.

    2017-07-01

    Proton beams may provide superior dose-conformity in radiation therapy. However, the large sizes and costs limit the widespread use of proton therapy (PT). The recent progress in proton acceleration via high-power laser systems has made it a compelling alternative to conventional accelerators, as it could potentially reduce the overall size and cost of the PT facilities. However, the laser-accelerated beams exhibit different characteristics than conventionally accelerated beams, i.e. very intense proton bunches with large divergences and broad-energy spectra. For the application of laser-driven beams in PT, new solutions for beam transport, such as beam capture, integrated energy selection, beam shaping and delivery systems are required due to the specific beam parameters. The generation of these beams are limited by the low repetition rate of high-power lasers and this limitation would require alternative solutions for tumour irradiation which can efficiently utilize the available high proton fluence and broad-energy spectra per proton bunch to keep treatment times short. This demands new dose delivery system and irradiation field formation schemes. In this paper, we present a multi-functional light-weight and compact proton gantry design for laser-driven sources based on iron-less pulsed high-field magnets. This achromatic design includes improved beam capturing and energy selection systems, with a novel beam shaping and dose delivery system, so-called ELPIS. ELPIS system utilizes magnetic fields, instead of physical scatterers, for broadening the spot-size of broad-energetic beams while capable of simultaneously scanning them in lateral directions. To investigate the clinical feasibility of this gantry design, we conducted a treatment planning study with a 3D treatment planning system augmented for the pulsed beams with optimizable broad-energetic widths and selectable beam spot sizes. High quality treatment plans could be achieved with such unconventional beam parameters, deliverable via the presented gantry and ELPIS dose delivery system. The conventional PT gantries are huge and require large space for the gantry to rotate the beam around the patient, which could be reduced up to 4 times with the presented pulse powered gantry system. The further developments in the next generation petawatt laser systems and laser-targets are crucial to reach higher proton energies. However, if proton energies required for therapy applications are reached it could be possible in future to reduce the footprint of the PT facilities, without compromising on clinical standards.

  18. A light-weight compact proton gantry design with a novel dose delivery system for broad-energetic laser-accelerated beams.

    PubMed

    Masood, U; Cowan, T E; Enghardt, W; Hofmann, K M; Karsch, L; Kroll, F; Schramm, U; Wilkens, J J; Pawelke, J

    2017-07-07

    Proton beams may provide superior dose-conformity in radiation therapy. However, the large sizes and costs limit the widespread use of proton therapy (PT). The recent progress in proton acceleration via high-power laser systems has made it a compelling alternative to conventional accelerators, as it could potentially reduce the overall size and cost of the PT facilities. However, the laser-accelerated beams exhibit different characteristics than conventionally accelerated beams, i.e. very intense proton bunches with large divergences and broad-energy spectra. For the application of laser-driven beams in PT, new solutions for beam transport, such as beam capture, integrated energy selection, beam shaping and delivery systems are required due to the specific beam parameters. The generation of these beams are limited by the low repetition rate of high-power lasers and this limitation would require alternative solutions for tumour irradiation which can efficiently utilize the available high proton fluence and broad-energy spectra per proton bunch to keep treatment times short. This demands new dose delivery system and irradiation field formation schemes. In this paper, we present a multi-functional light-weight and compact proton gantry design for laser-driven sources based on iron-less pulsed high-field magnets. This achromatic design includes improved beam capturing and energy selection systems, with a novel beam shaping and dose delivery system, so-called ELPIS. ELPIS system utilizes magnetic fields, instead of physical scatterers, for broadening the spot-size of broad-energetic beams while capable of simultaneously scanning them in lateral directions. To investigate the clinical feasibility of this gantry design, we conducted a treatment planning study with a 3D treatment planning system augmented for the pulsed beams with optimizable broad-energetic widths and selectable beam spot sizes. High quality treatment plans could be achieved with such unconventional beam parameters, deliverable via the presented gantry and ELPIS dose delivery system. The conventional PT gantries are huge and require large space for the gantry to rotate the beam around the patient, which could be reduced up to 4 times with the presented pulse powered gantry system. The further developments in the next generation petawatt laser systems and laser-targets are crucial to reach higher proton energies. However, if proton energies required for therapy applications are reached it could be possible in future to reduce the footprint of the PT facilities, without compromising on clinical standards.

  19. The roles of the Q (q) wave in lead I and QRS frontal axis for diagnosing loss of left ventricular capture during cardiac resynchronization therapy.

    PubMed

    Cao, Yuan-Yuan; Su, Yan-Gang; Bai, Jin; Wang, Wei; Wang, Jing-Feng; Qin, Sheng-Mei; Ge, Jun-Bo

    2015-01-01

    Loss of left ventricular (LV) capture may lead to deterioration of heart failure in patients with cardiac resynchronization therapy (CRT). Recognition of loss of LV capture in time is important in clinical practice. A total of 422 electrocardiograms were acquired and analyzed from 53 CRT patients at 8 different pacing settings (LV only, right ventricle [RV] only, biventricular [BV] pacing with LV preactivation of 60, 40, 20, and 0 milliseconds and RV preactivation of 20 and 40 milliseconds). A modified Ammann algorithm by adding a third step-presence of Q (q, or QS) wave-to the original 2-step Ammann algorithm and a QRS axis shift method were devised to identify the loss of LV capture. The accuracy of modified Ammann algorithm was significantly higher than that of Ammann algorithm (78.9% vs. 69.1%, P < 0.001). The accuracy of the axis shift method was 66.4%, which was significantly lower than the modified Ammann algorithm (P < 0.001) and similar to the original one (P = 0.412). However, in the ECGs with QRS axis shift, 96.8% were correctly classified. LV preactivation or simultaneous BV activation and LV lead positioned in nonposterior or noninferior wall could elevate the accuracies of the modified Ammann algorithm and the QRS axis shift method. The accuracy of the modified Ammann algorithm is greatly improved. The QRS axis shift method can help diagnose LV capture. The LV preactivation, or simultaneous BV activation and LV lead positioned in nonposterior or noninferior wall can increase the diagnostic power of the modified Ammann algorithm and QRS axis shift method. © 2014 Wiley Periodicals, Inc.

  20. Dendrimers

    NASA Astrophysics Data System (ADS)

    Bryant, L. Henry; Bulte, Jeff W. M.

    Dendrimers have received an enormous amount of attention in the last ten years and several recent review articles have appeared in the literature that address their potential applications [1-3]. Stoddart et al [1] have stated that: "We are now approaching a time when the study of dendriniers bec omes inextricably linked with many other fields, leaving the comprehensive reviewer of the subject a near-impossible task to fulfil". On that note, this review provides a brief introduction to the chemical principles of dendrimers by highlighting main synthetic strategies and methods for characterisation. p]Dendrimers containing heteroatoms will not be reviewed per se since these have recently been reviewed [4]. The major thrust of this review is the potential applications of dendrimers in such areas as boron neutron capture therapy, as contrast agents in magnetic resonance imaging, as vaccines, as cellular transfection agents and as bioconjugate dendrimers, i.e., in-vitro immunoassays for antigens. The outline used in this review proved to be effective in classifying most published papers about dendrimers, but it must be kept in mind that some articles not only transcended two different classifications, such as synthesis and characterisation, but several classifications such as synthesis, characterisation and at least one potential application covered in this review.

  1. Use of regularized principal component analysis to model anatomical changes during head and neck radiation therapy for treatment adaptation and response assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chetvertkov, Mikhail A., E-mail: chetvertkov@wayne

    2016-10-15

    Purpose: To develop standard (SPCA) and regularized (RPCA) principal component analysis models of anatomical changes from daily cone beam CTs (CBCTs) of head and neck (H&N) patients and assess their potential use in adaptive radiation therapy, and for extracting quantitative information for treatment response assessment. Methods: Planning CT images of ten H&N patients were artificially deformed to create “digital phantom” images, which modeled systematic anatomical changes during radiation therapy. Artificial deformations closely mirrored patients’ actual deformations and were interpolated to generate 35 synthetic CBCTs, representing evolving anatomy over 35 fractions. Deformation vector fields (DVFs) were acquired between pCT and syntheticmore » CBCTs (i.e., digital phantoms) and between pCT and clinical CBCTs. Patient-specific SPCA and RPCA models were built from these synthetic and clinical DVF sets. EigenDVFs (EDVFs) having the largest eigenvalues were hypothesized to capture the major anatomical deformations during treatment. Results: Principal component analysis (PCA) models achieve variable results, depending on the size and location of anatomical change. Random changes prevent or degrade PCA’s ability to detect underlying systematic change. RPCA is able to detect smaller systematic changes against the background of random fraction-to-fraction changes and is therefore more successful than SPCA at capturing systematic changes early in treatment. SPCA models were less successful at modeling systematic changes in clinical patient images, which contain a wider range of random motion than synthetic CBCTs, while the regularized approach was able to extract major modes of motion. Conclusions: Leading EDVFs from the both PCA approaches have the potential to capture systematic anatomical change during H&N radiotherapy when systematic changes are large enough with respect to random fraction-to-fraction changes. In all cases the RPCA approach appears to be more reliable at capturing systematic changes, enabling dosimetric consequences to be projected once trends are established early in a treatment course, or based on population models.« less

  2. Gadolinium diethylenetriaminopentaacetic acid-loaded chitosan microspheres for gadolinium neutron-capture therapy.

    PubMed

    Saha, Tapan Kumar; Ichikawa, Hideki; Fukumori, Yoshinobu

    2006-12-11

    In order to provide a suitable device that would contain water-soluble drugs, highly water-soluble gadolinium diethylenetriaminopentaacetic acid-loaded chitosan microspheres (CMS-Gd-DTPA) were prepared by the emulsion method using glutaraldehyde as a cross-linker and Span 80 as a surfactant for gadolinium neutron-capture therapy of cancer. The gadolinium content and the mass median diameter of CMS-Gd-DTPA were estimated. The size and morphology of the CMS-Gd-DTPA were strongly influenced by the initial applied weight ratio of Gd-DTPA:chitosan. FTIR spectra showed that the electrostatic interaction between chitosan and Gd-DTPA accelerated the formation of gadolinium-enriched chitosan microspheres. Sufficient amounts of glutaraldehyde and Span 80 were necessary for producing discrete CMS-Gd-DTPA. The CMS-Gd-DTPA having a mass median diameter 11.7microm and 11.6% of gadolinium could be used in Gd-NCT following intratumoral injection.

  3. Carboranylporphyrins and uses thereof

    DOEpatents

    Miura, Michiko; Renner, Mark W

    2012-10-16

    The present invention is directed to low toxicity boronated compounds and methods for their use in the treatment, visualization, and diagnosis of tumors. More specifically, the present invention is directed to low toxicity carborane-containing porphyrin compounds with halide, amine, or nitro groups and methods for their use particularly in boron neutron capture therapy (BNCT), X-ray radiation therapy (XRT), and photodynamic therapy (PDT) for the treatment of tumors of the brain, head and neck, and surrounding tissue. The invention is also directed to using these carborane-containing porphyrin compounds in methods of tumor imaging and/or diagnosis such as MRI, SPECT, or PET.

  4. Carbonylporphyrins and uses thereof

    DOEpatents

    Miura, Michiko; Renner, Mark W

    2014-03-18

    The present invention is directed to low toxicity boronated compounds and methods for their use in the treatment, visualization, and diagnosis of tumors. More specifically, the present invention is directed to low toxicity carborane-containing porphyrin compounds with halide, amine, or nitro groups and methods for their use particularly in boron neutron capture therapy (BNCT), X-ray radiation therapy (XRT), and photodynamic therapy (PDT) for the treatment of tumors of the brain, head and neck, and surrounding tissue. The invention is also directed to using these carborane-containing porphyrin compounds in methods of tumor imaging and/or diagnosis such as MRI, SPECT, or PET.

  5. Liposome-based delivery of a boron-containing cholesteryl ester for high-LET particle-induced damage of prostate cancer cells: a boron neutron capture therapy study.

    PubMed

    Gifford, Ian; Vreeland, Wyatt; Grdanovska, Slavica; Burgett, Eric; Kalinich, John; Vergara, Vernieda; Wang, C-K Chris; Maimon, Eric; Poster, Dianne; Al-Sheikhly, Mohamad

    2014-06-01

    The efficacy of a boron-containing cholesteryl ester compound (BCH) as a boron neutron capture therapy (BNCT) agent for the targeted irradiation of PC-3 human prostate cancer cells was examined. Liposome-based delivery of BCH was quantified with inductively coupled plasma-mass spectrometry (ICP-MS) and high-performance liquid chromatography (HPLC). Cytotoxicity of the BCH-containing liposomes was evaluated with neutral red, 3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium (MTS), and lactate dehydrogenase assays. Colony formation assays were utilized to evaluate the decrease in cell survival due to high-linear energy transfer (LET) particles resulting from (10)B thermal neutron capture. BCH delivery by means of encapsulation in a lipid bilayer resulted in a boron uptake of 35.2 ± 4.3 μg/10(9) cells, with minimal cytotoxic effects. PC-3 cells treated with BCH and exposed to a 9.4 × 10(11) n/cm(2) thermal neutron fluence yielded a 20-25% decrease in clonogenic capacity. The decreased survival is attributed to the generation of high-LET α particles and (7)Li nuclei that deposit energy in densely ionizing radiation tracks. Liposome-based delivery of BCH is capable of introducing sufficient boron to PC-3 cells for BNCT. High-LET α particles and (7)Li nuclei generated from (10)B thermal neutron capture significantly decrease colony formation ability in the targeted PC-3 cells.

  6. 77 FR 5045 - Endangered Species Recovery Permit Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-01

    ... take (survey, capture, handle, and release) the California tiger salamander (Ambystoma californiense..., capture, handle, and release) the California tiger salamander (Ambystoma californiense) and arroyo toad...

  7. 77 FR 37700 - Endangered Species Recovery Permit Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-22

    ... take (survey, capture, handle, and release) the California tiger salamander (Ambystoma californiense... permit to take (survey, capture, handle, and release) the California tiger salamander (Ambystoma...

  8. Design study of multi-imaging plate system for BNCT irradiation field at Kyoto university reactor.

    PubMed

    Tanaka, Kenichi; Sakurai, Yoshinori; Kajimoto, Tsuyoshi; Tanaka, Hiroki; Takata, Takushi; Endo, Satoru

    2016-09-01

    The converter configuration for a multi-imaging plate system was investigated for the application of quality assurance in the irradiation field profile for boron neutron capture therapy. This was performed by the simulation calculation using the PHITS code in the fields at the Heavy Water Neutron Irradiation Facility of Kyoto University Reactor. The converter constituents investigated were carbon for gamma rays, and polyethylene with and without LiF at varied (6)Li concentration for thermal, epithermal, and fast neutrons. Consequently, potential combinations of the converters were found for two components, gamma rays and thermal neutrons, for the standard thermal neutron mode and three components of gamma rays, epithermal neutrons, and thermal or fast neutrons, for the standard mixed or epithermal neutron modes, respectively. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Characteristics and application of spherical-type activation detectors in neutron spectrum measurements at a boron neutron capture therapy (BNCT) facility

    NASA Astrophysics Data System (ADS)

    Lin, Heng-Xiao; Chen, Wei-Lin; Liu, Yuan-Hao; Sheu, Rong-Jiun

    2016-03-01

    A set of spherical-type activation detectors was developed aiming to provide better determination of the neutron spectrum at the Tsing Hua Open-pool Reactor (THOR) BNCT facility. An activation foil embedded in a specially designed spherical holder exhibits three advantages: (1) minimizing the effect of neutron angular dependence, (2) creating response functions with broadened coverage of neutron energies by introducing additional moderators or absorbers to the central activation foil, and (3) reducing irradiation time because of improved detection efficiencies to epithermal neutron beam. This paper presents the design concept and the calculated response functions of new detectors. Theoretical and experimental demonstrations of the performance of the detectors are provided through comparisons of the unfolded neutron spectra determined using this method and conventional multiple-foil activation techniques.

  10. Photodynamic therapy with 5-aminolevulinic acid: basic principles and applications

    NASA Astrophysics Data System (ADS)

    Pottier, Roy H.; Kennedy, James C.

    1996-01-01

    Numerous photosensitizing pigments that absorb visible light and are selectively retained in neoplastic tissue are being investigated as potential photochemotherapeutic agents. While much emphasis is being placed on the synthesis of new, far-red absorbing photosensitizers, an alternative approach has been to stimulate the human body to produce its own natural photosensitizer, namely protoporphyrin IX (PpIX). Exogenous 5-aminolevulinic acid (ALA) is rapidly bioconverted into PP by mitochondria, the process being particularly efficient in tumor cells. Since PpIX has a natural and rapid clearing mechanism (via the capture of iron in the process of being converted into heme), ALA-PDT does not suffer from lingering skin phototoxicity. ALA may be introduced orally, intravenously, or topically, and ALA-PDT has been shown to be effective in the treatment of both malignant and non-malignant lesions.

  11. Cytomics in predictive medicine

    NASA Astrophysics Data System (ADS)

    Tarnok, Attila; Valet, Guenther K.

    2004-07-01

    Predictive Medicine aims at the detection of changes in patient's disease state prior to the manifestation of deterioration or improvement of the current status. Patient-specific, disease-course predictions with >95% or >99% accuracy during therapy would be highly valuable for everyday medicine. If these predictors were available, disease aggravation or progression, frequently accompanied by irreversible tissue damage or therapeutic side effects, could then potentially be avoided by early preventive therapy. The molecular analysis of heterogeneous cellular systems (Cytomics) by cytometry in conjunction with pattern-oriented bioinformatic analysis of the multiparametric cytometric and other data provides a promising approach to individualized or personalized medical treatment or disease management. Predictive medicine is best implemented by cell oriented measurements e.g. by flow or image cytometry. Cell oriented gene or protein arrays as well as bead arrays for the capture of solute molecules form serum, plasma, urine or liquor are equally of high value. Clinical applications of predictive medicine by Cytomics will include multi organ failure in sepsis or non infectious posttraumatic shock in intensive care, or the pretherapeutic identification of high risk patients in cancer cytostatic. Early individualized therapy may provide better survival chances for individual patient at concomitant cost containment. Predictive medicine guided early reduction or stop of therapy may lower or abrogate potential therapeutic side effects. Further important aspects of predictive medicine concern the preoperative identification of patients with a tendency for postoperative complications or coronary artery disease patients with an increased tendency for restenosis. As a consequence, better patient care and new forms of inductive scientific hypothesis development based on the interpretation of predictive data patterns are at reach.

  12. Scalable Photogrammetric Motion Capture System "mosca": Development and Application

    NASA Astrophysics Data System (ADS)

    Knyaz, V. A.

    2015-05-01

    Wide variety of applications (from industrial to entertainment) has a need for reliable and accurate 3D information about motion of an object and its parts. Very often the process of movement is rather fast as in cases of vehicle movement, sport biomechanics, animation of cartoon characters. Motion capture systems based on different physical principles are used for these purposes. The great potential for obtaining high accuracy and high degree of automation has vision-based system due to progress in image processing and analysis. Scalable inexpensive motion capture system is developed as a convenient and flexible tool for solving various tasks requiring 3D motion analysis. It is based on photogrammetric techniques of 3D measurements and provides high speed image acquisition, high accuracy of 3D measurements and highly automated processing of captured data. Depending on the application the system can be easily modified for different working areas from 100 mm to 10 m. The developed motion capture system uses from 2 to 4 technical vision cameras for video sequences of object motion acquisition. All cameras work in synchronization mode at frame rate up to 100 frames per second under the control of personal computer providing the possibility for accurate calculation of 3D coordinates of interest points. The system was used for a set of different applications fields and demonstrated high accuracy and high level of automation.

  13. A Study of Vicon System Positioning Performance.

    PubMed

    Merriaux, Pierre; Dupuis, Yohan; Boutteau, Rémi; Vasseur, Pascal; Savatier, Xavier

    2017-07-07

    Motion capture setups are used in numerous fields. Studies based on motion capture data can be found in biomechanical, sport or animal science. Clinical science studies include gait analysis as well as balance, posture and motor control. Robotic applications encompass object tracking. Today's life applications includes entertainment or augmented reality. Still, few studies investigate the positioning performance of motion capture setups. In this paper, we study the positioning performance of one player in the optoelectronic motion capture based on markers: Vicon system. Our protocol includes evaluations of static and dynamic performances. Mean error as well as positioning variabilities are studied with calibrated ground truth setups that are not based on other motion capture modalities. We introduce a new setup that enables directly estimating the absolute positioning accuracy for dynamic experiments contrary to state-of-the art works that rely on inter-marker distances. The system performs well on static experiments with a mean absolute error of 0.15 mm and a variability lower than 0.025 mm. Our dynamic experiments were carried out at speeds found in real applications. Our work suggests that the system error is less than 2 mm. We also found that marker size and Vicon sampling rate must be carefully chosen with respect to the speed encountered in the application in order to reach optimal positioning performance that can go to 0.3 mm for our dynamic study.

  14. Increased capture of pediatric surgical complications utilizing a novel case-log web application to enhance quality improvement.

    PubMed

    Fisher, Jason C; Kuenzler, Keith A; Tomita, Sandra S; Sinha, Prashant; Shah, Paresh; Ginsburg, Howard B

    2017-01-01

    Documenting surgical complications is limited by multiple barriers and is not fostered in the electronic health record. Tracking complications is essential for quality improvement (QI) and required for board certification. Current registry platforms do not facilitate meaningful complication reporting. We developed a novel web application that improves accuracy and reduces barriers to documenting complications. We deployed a custom web application that allows pediatric surgeons to maintain case logs. The program includes a module for entering complication data in real time. Reminders to enter outcome data occur at key postoperative intervals to optimize recall of events. Between October 1, 2014, and March 31, 2015, frequencies of surgical complications captured by the existing hospital reporting system were compared with data aggregated by our application. 780 cases were captured by the web application, compared with 276 cases registered by the hospital system. We observed an increase in the capture of major complications when compared to the hospital dataset (14 events vs. 4 events). This web application improved real-time reporting of surgical complications, exceeding the accuracy of administrative datasets. Custom informatics solutions may help reduce barriers to self-reporting of adverse events and improve the data that presently inform pediatric surgical QI. Diagnostic study/Retrospective study. Level III - case control study. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Photoacoustic and ultrasound dual-modality imaging for inflammatory arthritis

    NASA Astrophysics Data System (ADS)

    Xu, Guan; Chamberland, David; Girish, Gandikota; Wang, Xueding

    2014-03-01

    Arthritis is a leading cause of disability, affecting 46 million of the population in the U.S. Rendering new optical contrast in articular tissues at high spatial and temporal resolution, emerging photoacoustic imaging (PAI) combined with more established ultrasound (US) imaging technologies provides unique opportunities for diagnosis and treatment monitoring of inflammatory arthritis. In addition to capturing peripheral bone and soft tissue images, PAI has the capability to quantify hemodynamic properties including regional blood oxygenation and blood volume, both abnormal in synovial tissues affected by arthritis. Therefore, PAI, especially when performed together with US, should be of considerable help for further understanding the pathophysiology of arthritis as well as assisting in therapeutic decisions, including assessing the efficacy of new pharmacological therapies. In this paper, we will review our recent work on the development of PAI for application to the diagnostic imaging and therapeutic monitoring of inflammatory arthritis. We will present the imaging results from a home-built imaging system and another one based on a commercial US. The performance of PAI in evaluating pharmacological therapy on animal model of arthritis will be shown. Moreover, our resent work on PAI and US dual-modality imaging of human peripheral joints in vivo will also be presented.

  16. Intrathecal baclofen therapy in paediatrics: a study protocol for an Australian multicentre, 10-year prospective audit.

    PubMed

    Stewart, Kirsty; Hutana, Gavin; Kentish, Megan

    2017-06-21

    Increasing clinical use of Intrathecal baclofen (ITB) in Australian tertiary paediatric hospitals, along with the need for standardised assessment and reporting of adverse events, saw the formation of the Australian Paediatric ITB Research Group (APIRG). APIRG developed a National ITB Audit tool designed to capture clinical outcomes and adverse events data for all Australian children and adolescents receiving ITB therapy. The Australian ITB Audit is a 10 year, longitudinal, prospective, clinical audit collecting all adverse events and assessment data across body functions and structure, participation and activity level domains of the ICF. Data will be collected at baseline, 6 and 12 months with ongoing capture of all adverse event data. This is the first Australian study that aims to capture clinical and adverse event data from a complete population of children with neurological impairment receiving a specific intervention between 2011 and 2021. This multi-centre study will inform ITB clinical practice in children and adolescents, direct patient selection, record and aid decision making regarding adverse events and investigate the impact of ITB therapy on family and patient quality of life. This project was approved by the individual Human Research Ethics committees at the six Australian tertiary hospitals involved in the study. Results will be published in various peer reviewed journals and presented at national and international conferences. ACTRN 12610000323022; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Patterns of Chemotherapy Use in a U.S.-Based Cohort of Patients with Metastatic Pancreatic Cancer.

    PubMed

    Abrams, Thomas A; Meyer, Gary; Meyerhardt, Jeffrey A; Wolpin, Brian M; Schrag, Deborah; Fuchs, Charles S

    2017-08-01

    Few population studies have examined patterns of systemic therapy administration in metastatic pancreatic cancer (MPC) or the predictors associated with specific treatment choices. We assessed 4,011 consecutive MPC patients who received chemotherapy between January 2005 and December 2015 at academic, private, and community-based oncology practices subscribing to a U.S.-wide chemotherapy order entry system capturing disease, patient, provider, and treatment data. Multivariate analyses of these prospectively recorded characteristics identified significant predictors of specific therapeutic choices. Overall, 100 different regimens were used in first-line treatment of MPC. First-line gemcitabine monotherapy usage fell steadily from 72% in 2006 to 16% in 2015. This steep decline mirrored increases in first-line usage of both 5 fluorouracil, leucovorin, irinotecan and oxaliplatin (FOLFIRINOX) and gemcitabine + nab-paclitaxel. Younger male patients were more likely to receive FOLFIRINOX as first-line treatment, whereas patients treated at community practices and by oncologists with lower MPC patient volume were more likely to receive gemcitabine plus nab-paclitaxel (all p  ≤ .05). Among all patients receiving first-line chemotherapy for MPC, 49% went on to receive second-line therapy and 19% received third-line therapy; administration of second- and third-line therapies increased steadily over the time course of follow-up. Younger patients and those treated by oncologists with higher MPC patient volume were more likely to receive second- and third-line therapies. This population-based study provides insight into treatment patterns of MPC in the U.S. Usage patterns varied greatly according to patient and provider characteristics. This study examined real world metastatic pancreatic cancer treatment patterns in the United States with the goals of understanding changes in chemotherapy treatment frequencies over time and determining the individual predictors that underlie the chemotherapy choices oncologists make for their patients. Our data set is unique in that it captured not only patient-level data, but also oncologist-level data. It also captured data from private and community practices as well as academic centers. To our knowledge, this is the only data set that can give this degree of insight into oncologist decision making practices. © AlphaMed Press 2017.

  18. Integration of biomimicry and nanotechnology for significantly improved detection of circulating tumor cells (CTCs).

    PubMed

    Myung, Ja Hye; Park, Sin-Jung; Wang, Andrew Z; Hong, Seungpyo

    2017-12-13

    Circulating tumor cells (CTCs) have received a great deal of scientific and clinical attention as a biomarker for diagnosis and prognosis of many types of cancer. Given their potential significance in clinics, a variety of detection methods, utilizing the recent advances in nanotechnology and microfluidics, have been introduced in an effort of achieving clinically significant detection of CTCs. However, effective detection and isolation of CTCs still remain a tremendous challenge due to their extreme rarity and phenotypic heterogeneity. Among many approaches that are currently under development, this review paper focuses on a unique, promising approach that takes advantages of naturally occurring processes achievable through application of nanotechnology to realize significant improvement in sensitivity and specificity of CTC capture. We provide an overview of successful outcome of this biomimetic CTC capture system in detection of tumor cells from in vitro, in vivo, and clinical pilot studies. We also emphasize the clinical impact of CTCs as biomarkers in cancer diagnosis and predictive prognosis, which provides a cost-effective, minimally invasive method that potentially replaces or supplements existing methods such as imaging technologies and solid tissue biopsy. In addition, their potential prognostic values as treatment guidelines and that ultimately help to realize personalized therapy are discussed. Copyright © 2017. Published by Elsevier B.V.

  19. Utility of Policy Capturing as an Approach to Graduate Admissions Decision Making.

    ERIC Educational Resources Information Center

    Schmidt, Frank L.; And Others

    1978-01-01

    The present study examined and evaluated the application of linear policy-capturing models to the real-world decision task of graduate admissions. Utility of the policy-capturing models was great enough to be of practical significance, and least-squares weights showed no predictive advantage over equal weights. (Author/CTM)

  20. Boron neutron capture therapy for recurrent high-grade meningiomas.

    PubMed

    Kawabata, Shinji; Hiramatsu, Ryo; Kuroiwa, Toshihiko; Ono, Koji; Miyatake, Shin-Ichi

    2013-10-01

    Similar to glioblastomas, high-grade meningiomas are difficult pathologies to control. In this study, the authors used boron neutron capture therapy (BNCT), a tumor-selective intensive particle radiation modality, to treat high-grade meningioma. From June 2005 to September 2011, BNCT was applied 28 times in 20 cases of recurrent high-grade meningioma. All patients had previously undergone intensive treatments such as repetitive surgeries and multiple sessions of radiation therapy. Fluorine-18-labeled boronophenylalanine ((18)F-BPA) PET was performed before BNCT in 19 of the 20 cases; BPA is itself a therapeutic compound. Compound uptake, tumor shrinkage, long-term control rate including survival time, and failure pattern of the treated patients were all evaluated. Eighteen of 19 cases studied using (18)F-BPA PET showed good BPA uptake, with ratios of tumor to normal brain greater than 2.7. These ratios indicated the likely effects of BNCT prior to neutron irradiation. The original tumor sizes were between 4.3 cm(3) and 109 cm(3). A mean tumor volume reduction of 64.5% was obtained after BNCT within just 2 months. The median follow-up duration was 13 months. Six patients are still alive; at present, the median survival times after BNCT and diagnosis are 14.1 months (95% CI 8.6-40.4 months) and 45.7 months (95% CI 32.4-70.7 months), respectively. Clinical symptoms before BNCT, such as hemiparesis and facial pain, were improved after BNCT in symptomatic cases. Systemic metastasis, intracranial distant recurrence outside the radiation field, CSF dissemination, and local tumor progression were observed in 6, 7, 3, and 3 cases, respectively, during the clinical course. Apparent pseudoprogression was observed in at least 3 cases. Symptomatic radiation injuries occurred in 6 cases, and were controllable in all but 1 case. Boron neutron capture therapy may be especially effective in cases of high-grade meningioma.

  1. Sarcopenia during neoadjuvant therapy for oesophageal cancer: characterising the impact on muscle strength and physical performance.

    PubMed

    Guinan, Emer M; Doyle, S L; Bennett, A E; O'Neill, L; Gannon, J; Elliott, J A; O'Sullivan, J; Reynolds, J V; Hussey, J

    2018-05-01

    Preoperative chemo(radio)therapy for oesophageal cancer (OC) may have an attritional impact on body composition and functional status, impacting postoperative outcome. Physical decline with skeletal muscle loss has not been previously characterised in OC and may be amenable to physical rehabilitation. This study characterises skeletal muscle mass and physical performance from diagnosis to post-neoadjuvant therapy in patients undergoing preoperative chemo(radio)therapy for OC. Measures of body composition (axial computerised tomography), muscle strength (handgrip), functional capacity (walking distance), anthropometry (weight, height and waist circumference), physical activity, quality-of-life and nutritional status were captured prospectively. Sarcopenia status was defined as pre-sarcopenic (low muscle mass only), sarcopenic (low muscle mass and low muscle strength or function) or severely sarcopenic (low muscle mass and low muscle strength and low muscle function). Twenty-eight participants were studied at both time points (mean age 62.86 ± 8.18 years, n = 23 male). Lean body mass reduced by 4.9 (95% confidence interval 3.2 to 6.7) kg and mean grip strength reduced by 4.3 (2.5 to 6.1) kg from pre- to post-neoadjuvant therapy. Quality-of-life scores capturing gastrointestinal symptoms improved. Measures of anthropometry, walking distance, physical activity and nutritional status did not change. There was an increase in sarcopenic status from diagnosis (pre-sarcopenic n = 2) to post-treatment (pre-sarcopenic n = 5, severely sarcopenic n = 1). Despite maintenance of body weight, functional capacity and activity habits, participants experience declines in muscle mass and strength. Interventions involving exercise and/or nutritional support to build muscle mass and strength during preoperative therapy, even in patients who are functioning normally, are warranted.

  2. Boron Neutron Capture Therapy for HER2+ breast cancers: A feasibility study evaluating BNCT for potential role in breast conservation therapies

    NASA Astrophysics Data System (ADS)

    Jenkins, Peter Anthony

    A novel Boron Neutron Capture Therapy (BNCT) regimen for the treatment of HER2+ breast cancers has been proposed as an alternative to whole breast irradiation for breast conservation therapy patients. The proposed therapy regimen is based on the assumed production of boron delivery agents that would be synthesized from compounds of Trastuzumab (Herceptin ®) and oligomeric phosphate diesters (OPDs). The combination of the anti-HER2 monoclonal antibody and the high boron loading capability of OPDs has led to the assumption that boron could be delivered to the HER2+ cancer cells at Tumor to Healthy Tissue ratios (T:H) of up to 35:1 and boron concentrations above 50 μg/g. This significantly increased boron delivery efficiency has opened new BNCT possibilities. This proof of concept study examined treatment parameters derived as the results in previous efforts in the context of patient-specific geometry and compared calculated dose results to those observed during actual patient therapy. These results were based on dose calculations performed with a set of calculated Kerma coefficients derived from tissues specific to the regions of interest for breast cancer. A comparison was made of the dose to the tumor region, the patient's skin, and the peripheral organs. The results of this study demonstrated that, given the performance of the proposed boron delivery agent, the BNCT treatment regimen is feasible. The feasibility is based on the findings that the equivalent dose could be delivered to the treatment volume with less dose to the skin and peripheral organs. This is anticipated to improve the treatment outcomes by maintaining local control of tumor cells while reducing dose to healthy tissues.

  3. L-Boronophenylalanine-Mediated Boron Neutron Capture Therapy for Malignant Glioma Progressing After External Beam Radiation Therapy: A Phase I Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kankaanranta, Leena; Seppaelae, Tiina; Koivunoro, Hanna

    Purpose: To investigate the safety of boronophenylalanine-mediated boron neutron capture therapy (BNCT) in the treatment of malignant gliomas that progress after surgery and conventional external beam radiation therapy. Methods and Materials: Adult patients who had histologically confirmed malignant glioma that had progressed after surgery and external beam radiotherapy were eligible for this Phase I study, provided that >6 months had elapsed from the last date of radiation therapy. The first 10 patients received a fixed dose, 290 mg/kg, of L-boronophenylalanine-fructose (L-BPA-F) as a 2-hour infusion before neutron irradiation, and the remaining patients were treated with escalating doses of L-BPA-F, eithermore » 350 mg/kg, 400 mg/kg, or 450 mg/kg, using 3 patients on each dose level. Adverse effects were assessed using National Cancer Institute Common Toxicity Criteria version 2.0. Results: Twenty-two patients entered the study. Twenty subjects had glioblastoma, and 2 patients had anaplastic astrocytoma, and the median cumulative dose of prior external beam radiotherapy was 59.4 Gy. The maximally tolerated L-BPA-F dose was reached at the 450 mg/kg level, where 4 of 6 patients treated had a grade 3 adverse event. Patients who were given >290 mg/kg of L-BPA-F received a higher estimated average planning target volume dose than those who received 290 mg/kg (median, 36 vs. 31 Gy [W, i.e., a weighted dose]; p = 0.018). The median survival time following BNCT was 7 months. Conclusions: BNCT administered with an L-BPA-F dose of up to 400 mg/kg as a 2-hour infusion is feasible in the treatment of malignant gliomas that recur after conventional radiation therapy.« less

  4. Hydrodynamic Capture of Particles by Micro-swimmers under Hele-Shaw Flows

    NASA Astrophysics Data System (ADS)

    Mishler, Grant; Tsang, Alan Cheng Hou; Pak, On Shun

    2017-11-01

    We explore a hydrodynamic capture mechanism of a driven particle by a micro-swimmer in confined microfluidic environments with an idealized model. The capture is mediated by the hydrodynamic interactions between the micro-swimmer, the driven particle, and the background flow. This capture mechanism relies on the existence of attractive stable equilibrium configurations between the driven particle and the micro-swimmer, which occurs when the background flow is larger than a certain critical threshold. Dynamics and stability of capture and non-capture events will be discussed. This study may have potential applications in the study of capture and delivery of therapeutic payloads by micro-swimmers as well as particle self-assembly under confinements.

  5. Development of real-time thermal neutron monitor using boron-loaded plastic scintillator with optical fiber for boron neutron capture therapy.

    PubMed

    Ishikawa, M; Ono, K; Sakurai, Y; Unesaki, H; Uritani, A; Bengua, G; Kobayashi, T; Tanaka, K; Kosako, T

    2004-11-01

    A new thermal neutron monitor for boron neutron capture therapy was developed in this study. We called this monitor equipped boron-loaded plastic scintillator that uses optical fiber for signal transmission as an [scintillator with optical fiber] SOF detector. A water phantom experiment was performed to verify how the SOF detector compared with conventional method of measuring thermal neutron fluence. Measurements with a single SOF detector yielded indistinguishable signals for thermal neutrons and gamma rays. To account for the gamma ray contribution in the signal recorded by the SOF detector, a paired SOF detector system was employed. This was composed of an SOF detector with boron-loaded scintillator and an SOF detector with a boron-free scintillator. The difference between the recorded counts of these paired SOF detectors was used as the measure of the gamma ray contribution in the measured neutron fluence. The paired SOF detectors were ascertained to be effective in measuring thermal neutron flux in the range above 10(6)(n/cm(2)/s). Clinical trials using paired SOF to measure thermal neutron flux during therapy confirmed that paired SOF detectors were effective as a real-time thermal neutron flux monitor.

  6. Synthesis of Immunotargeted Magneto-plasmonic Nanoclusters

    PubMed Central

    Wu, Chun-Hsien; Sokolov, Konstantin

    2014-01-01

    Magnetic and plasmonic properties combined in a single nanoparticle provide a synergy that is advantageous in a number of biomedical applications including contrast enhancement in novel magnetomotive imaging modalities, simultaneous capture and detection of circulating tumor cells (CTCs), and multimodal molecular imaging combined with photothermal therapy of cancer cells. These applications have stimulated significant interest in development of protocols for synthesis of magneto-plasmonic nanoparticles with optical absorbance in the near-infrared (NIR) region and a strong magnetic moment. Here, we present a novel protocol for synthesis of such hybrid nanoparticles that is based on an oil-in-water microemulsion method. The unique feature of the protocol described herein is synthesis of magneto-plasmonic nanoparticles of various sizes from primary blocks which also have magneto-plasmonic characteristics. This approach yields nanoparticles with a high density of magnetic and plasmonic functionalities which are uniformly distributed throughout the nanoparticle volume. The hybrid nanoparticles can be easily functionalized by attaching antibodies through the Fc moiety leaving the Fab portion that is responsible for antigen binding available for targeting. PMID:25177973

  7. 75 FR 20857 - Endangered Species Recovery Permit Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-21

    ... 2, 2003, 68 FR 67465) to take (survey, capture, handle, and release) the California tiger salamander... tiger salamander (Ambystoma californiense) and to take (capture, collect, and kill) the Conservancy...

  8. Capturing Petascale Application Characteristics with the Sequoia Toolkit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vetter, Jeffrey S; Bhatia, Nikhil; Grobelny, Eric M

    2005-01-01

    Characterization of the computation, communication, memory, and I/O demands of current scientific applications is crucial for identifying which technologies will enable petascale scientific computing. In this paper, we present the Sequoia Toolkit for characterizing HPC applications. The Sequoia Toolkit consists of the Sequoia trace capture library and the Sequoia Event Analysis Library, or SEAL, that facilitates the development of tools for analyzing Sequoia event traces. Using the Sequoia Toolkit, we have characterized the behavior of application runs with up to 2048 application processes. To illustrate the use of the Sequoia Toolkit, we present a preliminary characterization of LAMMPS, a molecularmore » dynamics application of great interest to the computational biology community.« less

  9. Capturing Cognitive Fingerprints for Active Authentication

    DTIC Science & Technology

    2014-10-01

    CAPTURING COGNITIVE FINGERPRINTS FOR ACTIVE AUTHENTICATION IOWA STATE UNIVERSITY OF SCIENCE & TECHNOLOGY OCTOBER 2014 FINAL TECHNICAL REPORT...REPORT TYPE FINAL TECHNICAL REPORT 3. DATES COVERED (From - To) SEP 2013 – APR 2014 4. TITLE AND SUBTITLE CAPTURING COGNITIVE FINGERPRINTS FOR ACTIVE...The project ended before the IRB application was approved. 15. SUBJECT TERMS Active Authentication, Cognitive Fingerprints , Biometric Modalities

  10. Music therapy with bereaved teenagers: a mixed methods perspective.

    PubMed

    McFerran, Katrina; Roberts, Melina; O'Grady, Lucy

    2010-07-01

    Qualitative investigations have indicated that music therapy groups may be beneficial for bereaved teenagers. The existing relationship between young people and music serves as a platform for connectedness and emotional expression that is utilised within a therapeutic, support group format. This investigation confirms this suggestion through grounded theory analysis of focus group interviews. Changes in self-perception were not found as a result of participation, however practically significant results were found on adolescent coping. These cannot be generalized because of the small sample size. Grief specific tools are recommended for use in future investigations in order to capture the emotional impact of music therapy grief work with adolescents.

  11. Performance Characteristics of a Kernel-Space Packet Capture Module

    DTIC Science & Technology

    2010-03-01

    Defense, or the United States Government . AFIT/GCO/ENG/10-03 PERFORMANCE CHARACTERISTICS OF A KERNEL-SPACE PACKET CAPTURE MODULE THESIS Presented to the...3.1.2.3 Prototype. The proof of concept for this research is the design, development, and comparative performance analysis of a kernel level N2d capture...changes to kernel code 5. Can be used for both user-space and kernel-space capture applications in order to control comparative performance analysis to

  12. Human health risk assessment of nitrosamines and nitramines for potential application in CO2 capture.

    PubMed

    Ravnum, S; Rundén-Pran, E; Fjellsbø, L M; Dusinska, M

    2014-07-01

    Emission and accumulation of carbon dioxide (CO2) in the atmosphere exert an environmental and climate change challenge. An attempt to deal with this challenge is made at Mongstad by application of amines for CO2 capture and storage (CO2 capture Mongstad (CCM) project). As part of the CO2 capture process, nitrosamines and nitramines may be emitted. Toxicological testing of nitrosamines and nitramines indicate a genotoxic potential of these substances. Here we present a risk characterization and assessment for five nitrosamines (N-Nitrosodi-methylamine (NDMA) N-Nitrosodi-ethylamine (NDEA), N-Nitroso-morpholine (NNM), N-Nitroso-piperidine (NPIP), and Dinitroso-piperazine (DNP)) and two nitramines (N-Methyl-nitramine (NTMA), Dimethyl-nitramine (NDTMA)), which are potentially emitted from the CO2 capture plant (CCP). Human health risk assessment of genotoxic non-threshold substances is a heavily debated topic, and no consensus methodology exists internationally. Extrapolation modeling from high-dose animal exposures to low-dose human exposures can be crucial for the final risk calculation. In the work presented here, different extrapolation models are discussed, and suggestions on applications are given. Then, preferred methods for calculating derived minimal effect level (DMEL) are presented with the selected nitrosamines and nitramines. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Validation of an enzyme-linked immunosorbent assay that detects Histoplasma capsulatum antigenuria in Colombian patients with AIDS for diagnosis and follow-up during therapy.

    PubMed

    Caceres, Diego H; Scheel, Christina M; Tobón, Angela M; Ahlquist Cleveland, Angela; Restrepo, Angela; Brandt, Mary E; Chiller, Tom; Gómez, Beatriz L

    2014-09-01

    We validated an antigen capture enzyme-linked immunosorbent assay (ELISA) in Colombian persons with AIDS and proven histoplasmosis and evaluated the correlation between antigenuria and clinical improvement during follow-up. The sensitivity of the Histoplasma capsulatum ELISA was 86%, and the overall specificity was 94%. The antigen test successfully monitored the response to therapy. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  14. Geometric rectification of camera-captured document images.

    PubMed

    Liang, Jian; DeMenthon, Daniel; Doermann, David

    2008-04-01

    Compared to typical scanners, handheld cameras offer convenient, flexible, portable, and non-contact image capture, which enables many new applications and breathes new life into existing ones. However, camera-captured documents may suffer from distortions caused by non-planar document shape and perspective projection, which lead to failure of current OCR technologies. We present a geometric rectification framework for restoring the frontal-flat view of a document from a single camera-captured image. Our approach estimates 3D document shape from texture flow information obtained directly from the image without requiring additional 3D/metric data or prior camera calibration. Our framework provides a unified solution for both planar and curved documents and can be applied in many, especially mobile, camera-based document analysis applications. Experiments show that our method produces results that are significantly more OCR compatible than the original images.

  15. A Novel Approach to High Definition, High-Contrast Video Capture in Abdominal Surgery

    PubMed Central

    Cosman, Peter H.; Shearer, Christopher J.; Hugh, Thomas J.; Biankin, Andrew V.; Merrett, Neil D.

    2007-01-01

    Objective: The aim of this study was to define the best available option for video capture of surgical procedures for educational and archival purposes, with a view to identifying methods of capturing high-quality footage and identifying common pitfalls. Summary Background Data: Several options exist for those who wish to record operative surgical techniques on video. While high-end equipment is an unnecessary expense for most surgical units, several techniques are readily available that do not require industrial-grade audiovisual recording facilities, but not all are suited to every surgical application. Methods: We surveyed and evaluated the available technology for video capture in surgery. Our evaluation included analyses of video resolution, depth of field, contrast, exposure, image stability, and frame composition, as well as considerations of cost, accessibility, utility, feasibility, and economies of scale. Results: Several video capture options were identified, and the strengths and shortcomings of each were catalogued. None of the commercially available options was deemed suitable for high-quality video capture of abdominal surgical procedures. A novel application of off-the-shelf technology was devised to address these issues. Conclusions: Excellent quality video capture of surgical procedures within deep body cavities is feasible using commonly available equipment and technology, with minimal technical difficulty. PMID:17414600

  16. Meaning and challenges in the practice of multiple therapeutic massage modalities: a combined methods study.

    PubMed

    Porcino, Antony J; Boon, Heather S; Page, Stacey A; Verhoef, Marja J

    2011-09-20

    Therapeutic massage and bodywork (TMB) practitioners are predominantly trained in programs that are not uniformly standardized, and in variable combinations of therapies. To date no studies have explored this variability in training and how this affects clinical practice. Combined methods, consisting of a quantitative, population-based survey and qualitative interviews with practitioners trained in multiple therapies, were used to explore the training and practice of TMB practitioners in Alberta, Canada. Of the 5242 distributed surveys, 791 were returned (15.1%). Practitioners were predominantly female (91.7%), worked in a range of environments, primarily private (44.4%) and home clinics (35.4%), and were not significantly different from other surveyed massage therapist populations. Seventy-seven distinct TMB therapies were identified. Most practitioners were trained in two or more therapies (94.4%), with a median of 8 and range of 40 therapies. Training programs varied widely in number and type of TMB components, training length, or both. Nineteen interviews were conducted. Participants described highly variable training backgrounds, resulting in practitioners learning unique combinations of therapy techniques. All practitioners reported providing individualized patient treatment based on a responsive feedback process throughout practice that they described as being critical to appropriately address the needs of patients. They also felt that research treatment protocols were different from clinical practice because researchers do not usually sufficiently acknowledge the individualized nature of TMB care provision. The training received, the number of therapies trained in, and the practice descriptors of TMB practitioners are all highly variable. In addition, clinical experience and continuing education may further alter or enhance treatment techniques. Practitioners individualize each patient's treatment through a highly adaptive process. Therefore, treatment provision is likely unique to each practitioner. These results may be of interest to researchers considering similar practice issues in other professions. The use of a combined-methods design effectively captured this complexity of TMB practice. TMB research needs to consider research approaches that can capture or adapt to the individualized nature of practice.

  17. New quantitative method for evaluation of motor functions applicable to spinal muscular atrophy.

    PubMed

    Matsumaru, Naoki; Hattori, Ryo; Ichinomiya, Takashi; Tsukamoto, Katsura; Kato, Zenichiro

    2018-03-01

    The aim of this study was to develop and introduce new method to quantify motor functions of the upper extremity. The movement was recorded using a three-dimensional motion capture system, and the movement trajectory was analyzed using newly developed two indices, which measure precise repeatability and directional smoothness. Our target task was shoulder flexion repeated ten times. We applied our method to a healthy adult without and with a weight, simulating muscle impairment. We also applied our method to assess the efficacy of a drug therapy for amelioration of motor functions in a non-ambulatory patient with spinal muscular atrophy. Movement trajectories before and after thyrotropin-releasing hormone therapy were analyzed. In the healthy adult, we found the values of both indices increased significantly when holding a weight so that the weight-induced deterioration in motor function was successfully detected. From the efficacy assessment of drug therapy in the patient, the directional smoothness index successfully detected improvements in motor function, which were also clinically observed by the patient's doctors. We have developed a new quantitative evaluation method of motor functions of the upper extremity. Clinical usability of this method is also greatly enhanced by reducing the required number of body-attached markers to only one. This simple but universal approach to quantify motor functions will provide additional insights into the clinical phenotypes of various neuromuscular diseases and developmental disorders. Copyright © 2017 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  18. DNA damage induced by boron neutron capture therapy is partially repaired by DNA ligase IV.

    PubMed

    Kondo, Natsuko; Sakurai, Yoshinori; Hirota, Yuki; Tanaka, Hiroki; Watanabe, Tsubasa; Nakagawa, Yosuke; Narabayashi, Masaru; Kinashi, Yuko; Miyatake, Shin-ichi; Hasegawa, Masatoshi; Suzuki, Minoru; Masunaga, Shin-ichiro; Ohnishi, Takeo; Ono, Koji

    2016-03-01

    Boron neutron capture therapy (BNCT) is a particle radiation therapy that involves the use of a thermal or epithermal neutron beam in combination with a boron ((10)B)-containing compound that specifically accumulates in tumor. (10)B captures neutrons and the resultant fission reaction produces an alpha ((4)He) particle and a recoiled lithium nucleus ((7)Li). These particles have the characteristics of high linear energy transfer (LET) radiation and therefore have marked biological effects. High-LET radiation is a potent inducer of DNA damage, specifically of DNA double-strand breaks (DSBs). The aim of the present study was to clarify the role of DNA ligase IV, a key player in the non-homologous end-joining repair pathway, in the repair of BNCT-induced DSBs. We analyzed the cellular sensitivity of the mouse embryonic fibroblast cell lines Lig4-/- p53-/- and Lig4+/+ p53-/- to irradiation using a thermal neutron beam in the presence or absence of (10)B-para-boronophenylalanine (BPA). The Lig4-/- p53-/- cell line had a higher sensitivity than the Lig4+/+ p53-/-cell line to irradiation with the beam alone or the beam in combination with BPA. In BNCT (with BPA), both cell lines exhibited a reduction of the 50 % survival dose (D 50) by a factor of 1.4 compared with gamma-ray and neutron mixed beam (without BPA). Although it was found that (10)B uptake was higher in the Lig4+/+ p53-/- than in the Lig4-/- p53-/- cell line, the latter showed higher sensitivity than the former, even when compared at an equivalent (10)B concentration. These results indicate that BNCT-induced DNA damage is partially repaired using DNA ligase IV.

  19. Boron Neutron Capture Therapy in the Treatment of Locally Recurred Head and Neck Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kankaanranta, Leena; Seppaelae, Tiina; Koivunoro, Hanna

    2007-10-01

    Purpose: Head and neck carcinomas that recur locally after conventional irradiation pose a difficult therapeutic problem. We evaluated safety and efficacy of boron neutron capture therapy (BNCT) in the treatment of such cancers. Methods and Materials: Twelve patients with inoperable, recurred, locally advanced (rT3, rT4, or rN2) head and neck cancer were treated with BNCT in a prospective, single-center Phase I-II study. Prior treatments consisted of surgery and conventionally fractionated photon irradiation to a cumulative dose of 56-74 Gy administered with or without concomitant chemotherapy. Tumor responses were assessed using the RECIST (Response Evaluation Criteria in Solid Tumors) criteria andmore » adverse effects using the National Cancer Institute common toxicity grading v3.0. Intravenously administered boronophenylalanine-fructose (BPA-F, 400 mg/kg) was used as the boron carrier. Each patient was scheduled to be treated twice with BNCT. Results: Ten patients received BNCT twice; 2 were treated once. Ten (83%) patients responded to BNCT, and 2 (17%) had tumor growth stabilization for 5.5 and 7.6 months. The median duration of response was 12.1 months; six responses were ongoing at the time of analysis or death (range, 4.9-19.2 months). Four (33%) patients were alive without recurrence with a median follow-up of 14.0 months (range, 12.8-19.2 months). The most common acute adverse effects were mucositis, fatigue, and local pain; 2 patients had a severe (Grade 3) late adverse effect (xerostomia, 1; dysphagia, 1). Conclusions: Boron neutron capture therapy is effective and safe in the treatment of inoperable, locally advanced head and neck carcinomas that recur at previously irradiated sites.« less

  20. Dynamic application of microprojection arrays to skin induces circulating protein extravasation for enhanced biomarker capture and detection.

    PubMed

    Coffey, Jacob W; Meliga, Stefano C; Corrie, Simon R; Kendall, Mark A F

    2016-04-01

    Surface modified microprojection arrays are a needle-free alternative to capture circulating biomarkers from the skin in vivo for diagnosis. The concentration and turnover of biomarkers in the interstitial fluid, however, may limit the amount of biomarker that can be accessed by microprojection arrays and ultimately their capture efficiency. Here we report that microprojection array insertion induces protein extravasation from blood vessels and increases the concentration of biomarkers in skin, which can synergistically improve biomarker capture. Regions of blood vessels in skin were identified in the upper dermis and subcutaneous tissue by multi-photon microscopy. Insertion of microprojection array designs with varying projection length (40-190 μm), density (5000-20,408 proj.cm(-2)) and array size (4-36 mm(2)) did not affect the degree of extravasation. Furthermore, the location of extravasated protein did not correlate with projection penetration to these highly vascularised regions, suggesting extravasation was not caused by direct puncture of blood vessels. Biomarker extravasation was also induced by dynamic application of flat control surfaces, and varied with the impact velocity, further supporting this conclusion. The extravasated protein distribution correlated well with regions of high mechanical stress generated during insertion, quantified by finite element models. Using this approach to induce extravasation prior to microprojection array-based biomarker capture, anti-influenza IgG was captured within a 2 min application time, demonstrating that extravasation can lead to rapid biomarker sampling and significantly improved microprojection array capture efficiency. These results have broad implications for the development of transdermal devices that deliver to and sample from the skin. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  1. High-Throughput Screening of a Luciferase Reporter of Gene Silencing on the Inactive X Chromosome.

    PubMed

    Keegan, Alissa; Plath, Kathrin; Damoiseaux, Robert

    2018-01-01

    Assays of luciferase gene activity are a sensitive and quantitative reporter system suited to high-throughput screening. We adapted a luciferase assay to a screening strategy for identifying factors that reactivate epigenetically silenced genes. This epigenetic luciferase reporter is subject to endogenous gene silencing mechanisms on the inactive X chromosome (Xi) in primary mouse cells and thus captures the multilayered nature of chromatin silencing in development. Here, we describe the optimization of an Xi-linked luciferase reactivation assay in 384-well format and adaptation of the assay for high-throughput siRNA and chemical screening. Xi-luciferase reactivation screening has applications in stem cell biology and cancer therapy. We have used the approach described here to identify chromatin-modifying proteins and to identify drug combinations that enhance the gene reactivation activity of the DNA demethylating drug 5-aza-2'-deoxycytidine.

  2. Different approaches to acute organophosphorus poison treatment.

    PubMed

    Nurulain, Syed Muhammad

    2012-07-01

    Organophosphorus compounds (OPCs) have a wide variety of applications and are a serious threat for self-poisoning, unintentional misuse, terrorist attack, occupational hazard and warfare attack. The present standard treatment has been reported to be unsatisfactory. Many novel approaches are being used and tested for acute organophosphorus (OP) poison treatment. The bioscavenger concept captured high attention among the scientific community during the last few decades. Other approaches like alkalinisation of blood plasma/serum and use of weak inhibitors against strong inhibitors, though it showed promising results, did not get such wide attention. The introduction of a novel broad-spectrum oxime has also been in focus. In this mini-review, an update of the overview of four different approaches has been discussed. The standard therapy that is atropine+oxime+benzodiazepine along with supportive measures will continue to be the best option with only the replacement of a single oxime to improve its broad-spectrum efficacy.

  3. Feasibility study of using laser-generated neutron beam for BNCT.

    PubMed

    Kasesaz, Y; Rahmani, F; Khalafi, H

    2015-09-01

    The feasibility of using a laser-accelerated proton beam to produce a neutron source, via (p,n) reaction, for Boron Neutron Capture Therapy (BNCT) applications has been studied by MCNPX Monte Carlo code. After optimization of the target material and its thickness, a Beam Shaping Assembly (BSA) has been designed and optimized to provide appropriate neutron beam according to the recommended criteria by International Atomic Energy Agency. It was found that the considered laser-accelerated proton beam can provide epithermal neutron flux of ∼2×10(6) n/cm(2) shot. To achieve an appropriate epithermal neutron flux for BNCT treatment, the laser must operate at repetition rates of 1 kHz, which is rather ambitious at this moment. But it can be used in some BNCT researches field such as biological research. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Subcellular boron and fluorine distributions with SIMS ion microscopy in BNCT and cancer research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Subhash Chandra

    2008-05-30

    The development of a secondary ion mass spectrometry (SIMS) based technique of Ion Microscopy in boron neutron capture therapy (BNCT) was the main goal of this project, so that one can study the subcellular location of boron-10 atoms and their partitioning between the normal and cancerous tissue. This information is fundamental for the screening of boronated drugs appropriate for neutron capture therapy of cancer. Our studies at Cornell concentrated mainly on studies of glioblastoma multiforme (GBM). The early years of the grant were dedicated to the development of cryogenic methods and correlative microscopic approaches so that a reliable subcellular analysismore » of boron-10 atoms can be made with SIMS. In later years SIMS was applied to animal models and human tissues of GBM for studying the efficacy of potential boronated agents in BNCT. Under this grant the SIMS program at Cornell attained a new level of excellence and collaborative SIMS studies were published with leading BNCT researchers in the U.S.« less

  5. Nuclear magnetic resonance study of Gd-based nanoparticles to tag boron compounds in boron neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Corti, M.; Bonora, M.; Borsa, F.; Bortolussi, S.; Protti, N.; Santoro, D.; Stella, S.; Altieri, S.; Zonta, C.; Clerici, A. M.; Cansolino, L.; Ferrari, C.; Dionigi, P.; Porta, A.; Zanoni, G.; Vidari, G.

    2011-04-01

    We report the investigation of new organic complexes containing a magnetic moment (Gd-based molecular nanomagnets), which can serve the double purpose of acting as boron neutron capture therapy (BNCT) agents, and at the same time act as contrast agents to detect the molecule in the tissue by a proton magnetic resonance imaging (MRI). We also explore the possibility of monitoring the concentration of the BNCT agent directly via proton and boron NMR relaxation. The absorption of 10B-enriched molecules inside tumoral liver tissues has been shown by NMR measurements and confirmed by α spectroscopy. A new molecular Gd-tagged nanomagnet and BNCT agent (GdBPA) has been synthesized and characterized measuring its relaxivity R1 between 10 kHz and 66 MHz, and its use as a contrast agent in MRI has been demonstrated. The NMR-based evidence of the absorption of GdBPA into living tumoral cells is also shown.

  6. Monitoring the distribution of prompt gamma rays in boron neutron capture therapy using a multiple-scattering Compton camera: A Monte Carlo simulation study

    NASA Astrophysics Data System (ADS)

    Lee, Taewoong; Lee, Hyounggun; Lee, Wonho

    2015-10-01

    This study evaluated the use of Compton imaging technology to monitor prompt gamma rays emitted by 10B in boron neutron capture therapy (BNCT) applied to a computerized human phantom. The Monte Carlo method, including particle-tracking techniques, was used for simulation. The distribution of prompt gamma rays emitted by the phantom during irradiation with neutron beams is closely associated with the distribution of the boron in the phantom. Maximum likelihood expectation maximization (MLEM) method was applied to the information obtained from the detected prompt gamma rays to reconstruct the distribution of the tumor including the boron uptake regions (BURs). The reconstructed Compton images of the prompt gamma rays were combined with the cross-sectional images of the human phantom. Quantitative analysis of the intensity curves showed that all combined images matched the predetermined conditions of the simulation. The tumors including the BURs were distinguishable if they were more than 2 cm apart.

  7. Boron Neutron Capture Therapy - A Literature Review

    PubMed Central

    Nedunchezhian, Kavitaa; Thiruppathy, Manigandan; Thirugnanamurthy, Sarumathi

    2016-01-01

    Boron Neutron Capture Therapy (BNCT) is a radiation science which is emerging as a hopeful tool in treating cancer, by selectively concentrating boron compounds in tumour cells and then subjecting the tumour cells to epithermal neutron beam radiation. BNCT bestows upon the nuclear reaction that occurs when Boron-10, a stable isotope, is irradiated with low-energy thermal neutrons to yield α particles (Helium-4) and recoiling lithium-7 nuclei. A large number of 10 Boron (10B) atoms have to be localized on or within neoplastic cells for BNCT to be effective, and an adequate number of thermal neutrons have to be absorbed by the 10B atoms to maintain a lethal 10B (n, α) lithium-7 reaction. The most exclusive property of BNCT is that it can deposit an immense dose gradient between the tumour cells and normal cells. BNCT integrates the fundamental focusing perception of chemotherapy and the gross anatomical localization proposition of traditional radiotherapy. PMID:28209015

  8. An accelerator-based Boron Neutron Capture Therapy (BNCT) facility based on the 7Li(p,n)7Be

    NASA Astrophysics Data System (ADS)

    Musacchio González, Elizabeth; Martín Hernández, Guido

    2017-09-01

    BNCT (Boron Neutron Capture Therapy) is a therapeutic modality used to irradiate tumors cells previously loaded with the stable isotope 10B, with thermal or epithermal neutrons. This technique is capable of delivering a high dose to the tumor cells while the healthy surrounding tissue receive a much lower dose depending on the 10B biodistribution. In this study, therapeutic gain and tumor dose per target power, as parameters to evaluate the treatment quality, were calculated. The common neutron-producing reaction 7Li(p,n)7Be for accelerator-based BNCT, having a reaction threshold of 1880.4 keV, was considered as the primary source of neutrons. Energies near the reaction threshold for deep-seated brain tumors were employed. These calculations were performed with the Monte Carlo N-Particle (MCNP) code. A simple but effective beam shaping assembly (BSA) was calculated producing a high therapeutic gain compared to previously proposed facilities with the same nuclear reaction.

  9. Hybrid Calcium Phosphate-Polymeric Micelles Incorporating Gadolinium Chelates for Imaging-Guided Gadolinium Neutron Capture Tumor Therapy.

    PubMed

    Mi, Peng; Dewi, Novriana; Yanagie, Hironobu; Kokuryo, Daisuke; Suzuki, Minoru; Sakurai, Yoshinori; Li, Yanmin; Aoki, Ichio; Ono, Koji; Takahashi, Hiroyuki; Cabral, Horacio; Nishiyama, Nobuhiro; Kataoka, Kazunori

    2015-06-23

    Gadolinium (Gd) chelates-loaded nanocarriers have high potential for achieving magnetic resonance imaging (MRI)-guided Gd neutron capture therapy (GdNCT) of tumors. Herein, we developed calcium phosphate micelles hybridized with PEG-polyanion block copolymers, and incorporated with the clinical MRI contrast agent Gd-diethylenetriaminepentaacetic acid (Gd-DTPA/CaP). The Gd-DTPA/CaP were nontoxic to cancer cells at the concentration of 100 μM based on Gd-DTPA, while over 50% of the cancer cells were killed by thermal neutron irradiation at this concentration. Moreover, the Gd-DTPA/CaP showed a dramatically increased accumulation of Gd-DTPA in tumors, leading to the selective contrast enhancement of tumor tissues for precise tumor location by MRI. The enhanced tumor-to-blood distribution ratio of Gd-DTPA/CaP resulted in the effective suppression of tumor growth without loss of body weight, indicating the potential of Gd-DTPA/CaP for safe cancer treatment.

  10. Rapid Isolation of Viable Circulating Tumor Cells from Patient Blood Samples

    PubMed Central

    Hughes, Andrew D.; Mattison, Jeff; Powderly, John D.; Greene, Bryan T.; King, Michael R.

    2012-01-01

    Circulating tumor cells (CTC) are cells that disseminate from a primary tumor throughout the circulatory system and that can ultimately form secondary tumors at distant sites. CTC count can be used to follow disease progression based on the correlation between CTC concentration in blood and disease severity1. As a treatment tool, CTC could be studied in the laboratory to develop personalized therapies. To this end, CTC isolation must cause no cellular damage, and contamination by other cell types, particularly leukocytes, must be avoided as much as possible2. Many of the current techniques, including the sole FDA-approved device for CTC enumeration, destroy CTC as part of the isolation process (for more information see Ref. 2). A microfluidic device to capture viable CTC is described, consisting of a surface functionalized with E-selectin glycoprotein in addition to antibodies against epithelial markers3. To enhance device performance a nanoparticle coating was applied consisting of halloysite nanotubes, an aluminosilicate nanoparticle harvested from clay4. The E-selectin molecules provide a means to capture fast moving CTC that are pumped through the device, lending an advantage over alternative microfluidic devices wherein longer processing times are necessary to provide target cells with sufficient time to interact with a surface. The antibodies to epithelial targets provide CTC-specificity to the device, as well as provide a readily adjustable parameter to tune isolation. Finally, the halloysite nanotube coating allows significantly enhanced isolation compared to other techniques by helping to capture fast moving cells, providing increased surface area for protein adsorption, and repelling contaminating leukocytes3,4. This device is produced by a straightforward technique using off-the-shelf materials, and has been successfully used to capture cancer cells from the blood of metastatic cancer patients. Captured cells are maintained for up to 15 days in culture following isolation, and these samples typically consist of >50% viable primary cancer cells from each patient. This device has been used to capture viable CTC from both diluted whole blood and buffy coat samples. Ultimately, we present a technique with functionality in a clinical setting to develop personalized cancer therapies. PMID:22733259

  11. Neutron Capture Gamma-Ray Libraries for Nuclear Applications

    NASA Astrophysics Data System (ADS)

    Sleaford, B. W.; Firestone, R. B.; Summers, N.; Escher, J.; Hurst, A.; Krticka, M.; Basunia, S.; Molnar, G.; Belgya, T.; Revay, Z.; Choi, H. D.

    2011-06-01

    The neutron capture reaction is useful in identifying and analyzing the gamma-ray spectrum from an unknown assembly as it gives unambiguous information on its composition. This can be done passively or actively where an external neutron source is used to probe an unknown assembly. There are known capture gamma-ray data gaps in the ENDF libraries used by transport codes for various nuclear applications. The Evaluated Gamma-ray Activation file (EGAF) is a new thermal neutron capture database of discrete line spectra and cross sections for over 260 isotopes that was developed as part of an IAEA Coordinated Research Project. EGAF is being used to improve the capture gamma production in ENDF libraries. For medium to heavy nuclei the quasi continuum contribution to the gamma cascades is not experimentally resolved. The continuum contains up to 90% of all the decay energy and is modeled here with the statistical nuclear structure code DICEBOX. This code also provides a consistency check of the level scheme nuclear structure evaluation. The calculated continuum is of sufficient accuracy to include in the ENDF libraries. This analysis also determines new total thermal capture cross sections and provides an improved RIPL database. For higher energy neutron capture there is less experimental data available making benchmarking of the modeling codes more difficult. We are investigating the capture spectra from higher energy neutrons experimentally using surrogate reactions and modeling this with Hauser-Feshbach codes. This can then be used to benchmark CASINO, a version of DICEBOX modified for neutron capture at higher energy. This can be used to simulate spectra from neutron capture at incident neutron energies up to 20 MeV to improve the gamma-ray spectrum in neutron data libraries used for transport modeling of unknown assemblies.

  12. Intact capture of hypervelocity projectiles

    NASA Technical Reports Server (NTRS)

    Tsou, P.

    1990-01-01

    The ability to capture projectiles intact at hypervelocities opens new applications in science and technology that would either not be possible or would be very costly by other means. This capability has been demonstrated in the laboratory for aluminum projectiles of 1.6 mm diameter, captured at 6 km/s, in one unmelted piece, and retaining up to 95% of the original mass. Furthermore, capture was accomplished passively using microcellular underdense polymer foam. Another advantage of capturing projectiles in an underdense medium is the ability of such a medium to preserve a record of the projectile's original velocity components of speed and direction. A survey of these experimental results is described in terms of a dozen parameters which characterize the amount of capture and the effect on the projectile due to different capture media.

  13. Intact capture of hypervelocity projectiles.

    PubMed

    Tsou, P

    1990-01-01

    The ability to capture projectiles intact at hypervelocities opens new applications in science and technology that would either not be possible or would be very costly by other means. This capability has been demonstrated in the laboratory for aluminum projectiles of 1.6 mm diameter, captured at 6 km/s, in one unmelted piece, and retaining up to 95% of the original mass. Furthermore, capture was accomplished passively using microcellular underdense polymer foam. Another advantage of capturing projectiles in an underdense medium is the ability of such a medium to preserve a record of the projectile's original velocity components of speed and direction. A survey of these experimental results is described in terms of a dozen parameters which characterize the amount of capture and the effect on the projectile due to different capture media.

  14. Circulating Tumor Cells: What Is in It for the Patient? A Vision towards the Future

    PubMed Central

    van de Stolpe, Anja; den Toonder, Jaap M. J.

    2014-01-01

    Knowledge on cellular signal transduction pathways as drivers of cancer growth and metastasis has fuelled development of “targeted therapy” which “targets” aberrant oncogenic signal transduction pathways. These drugs require nearly invariably companion diagnostic tests to identify the tumor-driving pathway and the cause of the abnormal pathway activity in a tumor sample, both for therapy response prediction as well as for monitoring of therapy response and emerging secondary drug resistance. Obtaining sufficient tumor material for this analysis in the metastatic setting is a challenge, and circulating tumor cells (CTCs) may provide an attractive alternative to biopsy on the premise that they can be captured from blood and the companion diagnostic test results are correctly interpreted. We discuss novel companion diagnostic directions, including the challenges, to identify the tumor driving pathway in CTCs, which in combination with a digital pathology platform and algorithms to quantitatively interpret complex CTC diagnostic results may enable optimized therapy response prediction and monitoring. In contrast to CTC-based companion diagnostics, CTC enumeration is envisioned to be largely replaced by cell free tumor DNA measurements in blood for therapy response and recurrence monitoring. The recent emergence of novel in vitro human model systems in the form of cancer-on-a-chip may enable elucidation of some of the so far elusive characteristics of CTCs, and is expected to contribute to more efficient CTC capture and CTC-based diagnostics. PMID:24879438

  15. Occurrence of simultaneous cathodal-anodal capture with left ventricular quadripolar leads for cardiac resynchronization therapy: an electrocardiogram evaluation.

    PubMed

    Occhetta, Eraldo; Dell'Era, Gabriele; Giubertoni, Ailia; Magnani, Andrea; Rametta, Francesco; Blandino, Alessandro; Magnano, Vincenzo; Malacrida, Maurizio; Marino, Paolo

    2017-04-01

    The occurrence of left ventricular (LV) anodal activation during pacing with modern multipolar cardiac resynchronization therapy (CRT) systems has never been reported. The aim of our study was to demonstrate, by means of electrocardiogram (ECG) analysis, the occurrence of simultaneous cathodal-anodal LV capture with quadripolar LV leads. We studied 10 first-time recipients of a CRT device equipped with a quadripolar LV lead. During follow-up, standard supine 12-lead ECGs were obtained in available cathode-to-anode LV pacing configurations with a pulse amplitude equal to twice the pacing threshold. The occurrence of simultaneous cathodal-anodal LV capture was defined as the presence of variations in electrocardiographic ventricular activation (EVA) when the distal tip (cathode)-to-device can (anode) pacing configuration was compared with the distal tip (cathode)-to-proximal ring (anode) configuration. In eight patients, we found differences in EVA when different LV sites were paced through the unipolar LV tip and unipolar LV ring configurations. In these patients, a difference in EVA was detected in 61.5% (59 of 96) of the ECG leads (marked difference in 31.3%, slight difference in 30.2%). Changes in EVA between unipolar tip-to-can and bipolar tip-to-ring pacing that were suggestive of cathodal-anodal LV capture were found in six patients. In these patients, a total of 30 (41.7%) ECG leads showed a difference in EVA (marked difference in 20.8%, slight difference in 20.8%). In our experience, additional anodal capture by the proximal LV ring during LV pacing is provable in most recipients of a resynchronization device equipped with a multipolar LV lead. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  16. Micromachined fragment capturer for biomedical applications.

    PubMed

    Choi, Young-Soo; Lee, Dong-Weon

    2011-11-01

    Due to changes in modern diet, a form of heart disease called chronic total occlusion has become a serious disease to be treated as an emergency. In this study, we propose a micromachined capturer that is designed and fabricated to collect plaque fragments generated during surgery to remove the thrombus. The fragment capturer consists of a plastic body made by rapid prototyping, SU-8 mesh structures using MEMS techniques, and ionic polymer metal composite (IPMC) actuators. An array of IPMC actuators combined with the SU-8 net structure was optimized to effectively collect plaque fragments. The evaporation of solvent through the actuator's surface was prevented using a coating of SU-8 and polydimethylsiloxane thin film on the actuator. This approach improved the available operating time of the IPMC, which primarily depends on solvent loss. Our preliminary results demonstrate the possibility of using the capturer for biomedical applications. © 2011 American Institute of Physics

  17. A Self-Assessment Stereo Capture Model Applicable to the Internet of Things

    PubMed Central

    Lin, Yancong; Yang, Jiachen; Lv, Zhihan; Wei, Wei; Song, Houbing

    2015-01-01

    The realization of the Internet of Things greatly depends on the information communication among physical terminal devices and informationalized platforms, such as smart sensors, embedded systems and intelligent networks. Playing an important role in information acquisition, sensors for stereo capture have gained extensive attention in various fields. In this paper, we concentrate on promoting such sensors in an intelligent system with self-assessment capability to deal with the distortion and impairment in long-distance shooting applications. The core design is the establishment of the objective evaluation criteria that can reliably predict shooting quality with different camera configurations. Two types of stereo capture systems—toed-in camera configuration and parallel camera configuration—are taken into consideration respectively. The experimental results show that the proposed evaluation criteria can effectively predict the visual perception of stereo capture quality for long-distance shooting. PMID:26308004

  18. Many-body formulation of carriers capture time in quantum dots applicable in device simulation codes

    NASA Astrophysics Data System (ADS)

    Vallone, Marco

    2010-03-01

    We present an application of Green's functions formalism to calculate in a simplified but rigorous way electrons and holes capture time in quantum dots in closed form as function of carrier density, levels confinement potential, and temperature. Carrier-carrier (Auger) scattering and single LO-phonon emission are both addressed accounting for dynamic effects of the potential screening in the single plasmon pole approximation of the dielectric function. Regarding the LO-phonons interaction, the formulation evidences the role of the dynamic screening from wetting-layer carriers in comparison with its static limit, describes the interplay between screening and Fermi band filling, and offers simple expressions for capture time, suitable for modeling implementation.

  19. Telerehabilitation: remote multimedia-supported assistance and mobile monitoring of balance training outcomes can facilitate the clinical staff's effort.

    PubMed

    Krpič, Andrej; Savanović, Arso; Cikajlo, Imre

    2013-06-01

    Telerehabilitation can offer prolonged rehabilitation for patients with stroke after being discharged from the hospital, whilst remote diagnostics may reduce the frequency of the outpatient services required. Here, we compared a novel telerehabilitation system for virtual reality-supported balance training with balance training with only a standing frame and with conventional therapy in the hospital. The proposed low-cost experimental system for balance training enabling multiple home systems, real-time tracking of task's performance and different views of captured data with balance training, consists of a standing frame equipped with a tilt sensor, a low-cost computer, display, and internet connection. Goal-based tasks for balance training in the virtual environment proved motivating for the participating individuals. The physiotherapist, located in the remote healthcare center, could remotely adjust the level of complexity and difficulty or preview the outcomes and instructions with the application on the mobile smartphone. Patients using the virtual reality-supported balance training showed an improvement in the task performance time of 45% and number of collisions of 68%, showing significant improvements in the Berg Balance Scale, Timed 'Up and Go', and 10 m Walk Test. The clinical outcomes were not significantly different from balance training with only the standing frame or conventional therapy. The proposed telerehabilitation can facilitate the physiotherapists' work and thus enable rehabilitation to a larger number of patients after release from the hospital because it requires less time and infrequent presence of the clinical staff. However, a comprehensive clinical evaluation is required to confirm the applicability of the concept.

  20. A Project of Boron Neutron Capture Therapy System based on a Proton Linac Neutron Source

    NASA Astrophysics Data System (ADS)

    Kiyanagi, Yoshikai; Asano, Kenji; Arakawa, Akihiro; Fukuchi, Shin; Hiraga, Fujio; Kimura, Kenju; Kobayashi, Hitoshi; Kubota, Michio; Kumada, Hiroaki; Matsumoto, Hiroshi; Matsumoto, Akira; Sakae, Takeji; Saitoh, Kimiaki; Shibata, Tokushi; Yoshioka, Masakazu

    At present, the clinical trials of Boron Neutron Capture Therapy (BNCT) are being performed at research reactor facilities. However, an accelerator based BNCT has a merit that it can be built in a hospital. So, we just launched a development project for the BNCT based on an accelerator in order to establish and to spread the BNCT as an effective therapy in the near future. In the project, a compact proton linac installed in a hospital will be applied as a neutron source, and energy of the proton beam is planned to be less than about 10 MeV to reduce the radioactivity. The BNCT requires epithermal neutron beam with an intensity of around 1x109 (n/cm2/sec) to deliver the therapeutic dose to a deeper region in a body and to complete the irradiation within an hour. From this condition, the current of the proton beam required is estimated to be a few mA on average. Enormous heat deposition in the target is a big issue. We are aiming at total optimization of the accelerator based BNCT from the linac to the irradiation position. Here, the outline of the project is introduced and the moderator design is presented.

  1. Boron neutron capture therapy induces cell cycle arrest and cell apoptosis of glioma stem/progenitor cells in vitro.

    PubMed

    Sun, Ting; Zhang, Zizhu; Li, Bin; Chen, Guilin; Xie, Xueshun; Wei, Yongxin; Wu, Jie; Zhou, Youxin; Du, Ziwei

    2013-08-06

    Glioma stem cells in the quiescent state are resistant to clinical radiation therapy. An almost inevitable glioma recurrence is due to the persistence of these cells. The high linear energy transfer associated with boron neutron capture therapy (BNCT) could kill quiescent and proliferative cells. The present study aimed to evaluate the effects of BNCT on glioma stem/progenitor cells in vitro. The damage induced by BNCT was assessed using cell cycle progression, apoptotic cell ratio and apoptosis-associated proteins expression. The surviving fraction and cell viability of glioma stem/progenitor cells were decreased compared with differentiated glioma cells using the same boronophenylalanine pretreatment and the same dose of neutron flux. BNCT induced cell cycle arrest in the G2/M phase and cell apoptosis via the mitochondrial pathway, with changes in the expression of associated proteins. Glioma stem/progenitor cells, which are resistant to current clinical radiotherapy, could be effectively killed by BNCT in vitro via cell cycle arrest and apoptosis using a prolonged neutron irradiation, although radiosensitivity of glioma stem/progenitor cells was decreased compared with differentiated glioma cells when using the same dose of thermal neutron exposure and boronophenylalanine pretreatment. Thus, BNCT could offer an appreciable therapeutic advantage to prevent tumor recurrence, and may become a promising treatment in recurrent glioma.

  2. Multi-Family Pediatric Pain Group Therapy: Capturing Acceptance and Cultivating Change.

    PubMed

    Huestis, Samantha E; Kao, Grace; Dunn, Ashley; Hilliard, Austin T; Yoon, Isabel A; Golianu, Brenda; Bhandari, Rashmi P

    2017-12-07

    Behavioral health interventions for pediatric chronic pain include cognitive-behavioral (CBT), acceptance and commitment (ACT), and family-based therapies, though literature regarding multi-family therapy (MFT) is sparse. This investigation examined the utility and outcomes of the Courage to Act with Pain: Teens Identifying Values, Acceptance, and Treatment Effects (CAPTIVATE) program, which included all three modalities (CBT, ACT, MFT) for youth with chronic pain and their parents. Program utility, engagement, and satisfaction were evaluated via quantitative and qualitative feedback. Pain-specific psychological, behavioral, and interpersonal processes were examined along with outcomes related to disability, quality of life, pain interference, fatigue, anxiety, and depressive symptoms. Participants indicated that CAPTIVATE was constructive, engaging, and helpful for social and family systems. Clinical and statistical improvements with large effect sizes were captured for pain catastrophizing, acceptance, and protective parenting but not family functioning. Similar effects were found for functional disability, pain interference, fatigue, anxiety, and depression. Given the importance of targeting multiple systems in the management of pediatric chronic pain, preliminary findings suggest a potential new group-based treatment option for youth and families. Next steps involve evaluating the differential effect of the program over treatment as usual, as well as specific CBT, ACT, and MFT components and processes that may affect outcomes.

  3. Space Telecommunications Radio System (STRS) Application Repository Design and Analysis

    NASA Technical Reports Server (NTRS)

    Handler, Louis M.

    2013-01-01

    The Space Telecommunications Radio System (STRS) Application Repository Design and Analysis document describes the STRS application repository for software-defined radio (SDR) applications intended to be compliant to the STRS Architecture Standard. The document provides information about the submission of artifacts to the STRS application repository, to provide information to the potential users of that information, and for the systems engineer to understand the requirements, concepts, and approach to the STRS application repository. The STRS application repository is intended to capture knowledge, documents, and other artifacts for each waveform application or other application outside of its project so that when the project ends, the knowledge is retained. The document describes the transmission of technology from mission to mission capturing lessons learned that are used for continuous improvement across projects and supporting NASA Procedural Requirements (NPRs) for performing software engineering projects and NASAs release process.

  4. 40 CFR Table 1 to Subpart IIIi of... - Operating Limits for Capture Systems and Add-On Control Devices

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Operating Limits for Capture Systems... 63—Operating Limits for Capture Systems and Add-On Control Devices If you are required to comply with operating limits by § 63.3093, you must comply with the applicable operating limits in the following table...

  5. 40 CFR Table 1 to Subpart IIIi of... - Operating Limits for Capture Systems and Add-On Control Devices

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 12 2011-07-01 2009-07-01 true Operating Limits for Capture Systems... 63—Operating Limits for Capture Systems and Add-On Control Devices If you are required to comply with operating limits by § 63.3093, you must comply with the applicable operating limits in the following table...

  6. 40 CFR Table 1 to Subpart IIIi of... - Operating Limits for Capture Systems and Add-On Control Devices

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 13 2013-07-01 2012-07-01 true Operating Limits for Capture Systems... Subpart IIII of Part 63—Operating Limits for Capture Systems and Add-On Control Devices If you are required to comply with operating limits by § 63.3093, you must comply with the applicable operating limits...

  7. 40 CFR Table 1 to Subpart IIIi of... - Operating Limits for Capture Systems and Add-On Control Devices

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 13 2012-07-01 2012-07-01 false Operating Limits for Capture Systems... Subpart IIII of Part 63—Operating Limits for Capture Systems and Add-On Control Devices If you are required to comply with operating limits by § 63.3093, you must comply with the applicable operating limits...

  8. 40 CFR Table 1 to Subpart IIIi of... - Operating Limits for Capture Systems and Add-On Control Devices

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 13 2014-07-01 2014-07-01 false Operating Limits for Capture Systems... Subpart IIII of Part 63—Operating Limits for Capture Systems and Add-On Control Devices If you are required to comply with operating limits by § 63.3093, you must comply with the applicable operating limits...

  9. Use of Multivariate Techniques to Validate and Improve the Current USAF Pilot Candidate Selection Model

    DTIC Science & Technology

    2003-03-01

    organizations . Reducing attrition rates through optimal selection decisions can “reduce training cost, improve job performance, and enhance...capturing the weights for use in the SNR method is not straightforward. A special VBA application had to be written to capture and organize the network...before the VBA application can be used. Appendix D provides the VBA code used to import and organize the network weights and input standardization

  10. Therapist Adherence in Brief Strategic Family Therapy for Adolescent Drug Abusers

    PubMed Central

    Robbins, Michael S.; Feaster, Daniel J.; Horigian, Viviana E.; Puccinelli, Marc J.; Henderson, Craig; Szapocznik, José

    2012-01-01

    Objective Therapist adherence has been shown to predict clinical outcomes in family therapy. In prior studies, adherence has been represented broadly by core principles and a consistent family (vs. individual) focus. To date, these studies have not captured the range of clinical skills that are represented in complex family-based approaches or examined how variations in these skills predict different clinically relevant outcomes over the course of treatment. In this study, the authors examined the reliability and validity of an observational adherence measure and the relationship between adherence and outcome in a sample of drug-using adolescents who received brief strategic family therapy within a multisite effectiveness study. Method Participants were 480 adolescents (age 12–17) and their family members, who were randomized to the Brief Strategic Family Therapist treatment condition (J. Szapocznik, U. Hervis, & S. Schwartz, 2003) or treatment as usual. The adolescents were mostly male (377 vs. 103 female) and Hispanic (213), whereas 148 were White, and 110 were Black. Therapists were also randomly assigned to treatment condition within agencies. Results Results supported the proposed factor structure of the adherence measure, providing evidence that it is possible to capture and discriminate between distinct dimensions of family therapy. Analyses demonstrated that the mean levels of the factors varied over time in theoretically and clinically relevant ways and that therapist adherence was associated with engagement and retention in treatment, improvements in family functioning, and reductions in adolescent drug use. Conclusions Clinical implications and future research directions are discussed, including the relevance of these findings on training therapists and studies focusing on mechanisms of action in family therapy. PMID:21261433

  11. Design framework for a spectral mask for a plenoptic camera

    NASA Astrophysics Data System (ADS)

    Berkner, Kathrin; Shroff, Sapna A.

    2012-01-01

    Plenoptic cameras are designed to capture different combinations of light rays from a scene, sampling its lightfield. Such camera designs capturing directional ray information enable applications such as digital refocusing, rotation, or depth estimation. Only few address capturing spectral information of the scene. It has been demonstrated that by modifying a plenoptic camera with a filter array containing different spectral filters inserted in the pupil plane of the main lens, sampling of the spectral dimension of the plenoptic function is performed. As a result, the plenoptic camera is turned into a single-snapshot multispectral imaging system that trades-off spatial with spectral information captured with a single sensor. Little work has been performed so far on analyzing diffraction effects and aberrations of the optical system on the performance of the spectral imager. In this paper we demonstrate simulation of a spectrally-coded plenoptic camera optical system via wave propagation analysis, evaluate quality of the spectral measurements captured at the detector plane, and demonstrate opportunities for optimization of the spectral mask for a few sample applications.

  12. Multiplexed evaluation of capture agent binding kinetics using arrays of silicon photonic microring resonators.

    PubMed

    Byeon, Ji-Yeon; Bailey, Ryan C

    2011-09-07

    High affinity capture agents recognizing biomolecular targets are essential in the performance of many proteomic detection methods. Herein, we report the application of a label-free silicon photonic biomolecular analysis platform for simultaneously determining kinetic association and dissociation constants for two representative protein capture agents: a thrombin-binding DNA aptamer and an anti-thrombin monoclonal antibody. The scalability and inherent multiplexing capability of the technology make it an attractive platform for simultaneously evaluating the binding characteristics of multiple capture agents recognizing the same target antigen, and thus a tool complementary to emerging high-throughput capture agent generation strategies.

  13. Mobile task management tool that improves workflow of an acute general surgical service.

    PubMed

    Foo, Elizabeth; McDonald, Rod; Savage, Earle; Floyd, Richard; Butler, Anthony; Rumball-Smith, Alistair; Connor, Saxon

    2015-10-01

    Understanding and being able to measure constraints within a health system is crucial if outcomes are to be improved. Current systems lack the ability to capture decision making with regard to tasks performed within a patient journey. The aim of this study was to assess the impact of a mobile task management tool on clinical workflow within an acute general surgical service by analysing data capture and usability of the application tool. The Cortex iOS application was developed to digitize patient flow and provide real-time visibility over clinical decision making and task performance. Study outcomes measured were workflow data capture for patient and staff events. Usability was assessed using an electronic survey. There were 449 unique patient journeys tracked with a total of 3072 patient events recorded. The results repository was accessed 7792 times. The participants reported that the application sped up decision making, reduced redundancy of work and improved team communication. The mode of the estimated time the application saved participants was 5-9 min/h of work. Of the 14 respondents, nine discarded their analogue methods of tracking tasks by the end of the study period. The introduction of a mobile task management system improved the working efficiency of junior clinical staff. The application allowed capture of data not previously available to hospital systems. In the future, such data will contribute to the accurate mapping of patient journeys through the health system. © 2015 Royal Australasian College of Surgeons.

  14. Laser capture microdissection: Arcturus(XT) infrared capture and UV cutting methods.

    PubMed

    Gallagher, Rosa I; Blakely, Steven R; Liotta, Lance A; Espina, Virginia

    2012-01-01

    Laser capture microdissection (LCM) is a technique that allows the precise procurement of enriched cell populations from a heterogeneous tissue under direct microscopic visualization. LCM can be used to harvest the cells of interest directly or can be used to isolate specific cells by ablating the unwanted cells, resulting in histologically enriched cell populations. The fundamental components of laser microdissection technology are (a) visualization of the cells of interest via microscopy, (b) transfer of laser energy to a thermolabile polymer with either the formation of a polymer-cell composite (capture method) or transfer of laser energy via an ultraviolet laser to photovolatize a region of tissue (cutting method), and (c) removal of cells of interest from the heterogeneous tissue section. Laser energy supplied by LCM instruments can be infrared (810 nm) or ultraviolet (355 nm). Infrared lasers melt thermolabile polymers for cell capture, whereas ultraviolet lasers ablate cells for either removal of unwanted cells or excision of a defined area of cells. LCM technology is applicable to an array of applications including mass spectrometry, DNA genotyping and loss-of-heterozygosity analysis, RNA transcript profiling, cDNA library generation, proteomics discovery, and signal kinase pathway profiling. This chapter describes the unique features of the Arcturus(XT) laser capture microdissection instrument, which incorporates both infrared capture and ultraviolet cutting technology in one instrument, using a proteomic downstream assay as a model.

  15. A technical, economic, and environmental assessment of amine-based CO2 capture technology for power plant greenhouse gas control.

    PubMed

    Rao, Anand B; Rubin, Edward S

    2002-10-15

    Capture and sequestration of CO2 from fossil fuel power plants is gaining widespread interest as a potential method of controlling greenhouse gas emissions. Performance and cost models of an amine (MEA)-based CO2 absorption system for postcombustion flue gas applications have been developed and integrated with an existing power plant modeling framework that includes multipollutant control technologies for other regulated emissions. The integrated model has been applied to study the feasibility and cost of carbon capture and sequestration at both new and existing coal-burning power plants. The cost of carbon avoidance was shown to depend strongly on assumptions about the reference plant design, details of the CO2 capture system design, interactions with other pollution control systems, and method of CO2 storage. The CO2 avoidance cost for retrofit systems was found to be generally higher than for new plants, mainly because of the higher energy penalty resulting from less efficient heat integration as well as site-specific difficulties typically encountered in retrofit applications. For all cases, a small reduction in CO2 capture cost was afforded by the SO2 emission trading credits generated by amine-based capture systems. Efforts are underway to model a broader suite of carbon capture and sequestration technologies for more comprehensive assessments in the context of multipollutant environmental management.

  16. Gd@C82 metallofullerenes for neutron capture therapy—fullerene solubilization by poly(ethylene glycol)-block-poly(2-(N, N-diethylamino)ethyl methacrylate) and resultant efficacy in vitro

    PubMed Central

    Horiguchi, Yukichi; Kudo, Shinpei; Nagasaki, Yukio

    2011-01-01

    Poly(ethylene glycol)-block-poly(2-(N,N-diethylamino)ethyl methacrylate) (PEG-b-PAMA) was found to solubilize fullerenes such as C60, and this technique was applied to metallofullerenes. Gd@C82 was easily dissolved in water in the presence of PEG-b-PAMA without any covalent derivatization, forming a transparent complex about 20–30 nm in diameter. Low cytotoxicity was confirmed in vitro. Neutron irradiation of cultured cells (colon-26 adenocarcinoma) with Gd@C82-PEG-b-PAMA-complexed nanoparticles showed effective cytotoxicity, indicating the effective emission of gamma rays and internal conversion electrons produced from the neutron capture reaction of Gd. This result suggests a potentially valuable approach to gadolinium-based neutron capture therapy. PMID:27877415

  17. Distribution of health-related social surplus in pharmaceuticals: an estimation of consumer and producer surplus in the management of high blood lipids and COPD.

    PubMed

    Refoios Camejo, Rodrigo; Camejo, Rodrigo Refoios; McGrath, Clare; Miraldo, Marisa; Rutten, Frans

    2014-05-01

    Following suggestions that developers should be allowed to capture a defined share of the total value generated by their technologies, the amount of surplus accruing to the pharmaceutical industry has become an important concept when discussing policies to encourage innovation in healthcare. Observational clinical and market data spanning over a period of 20 years were applied in order to estimate the social surplus generated by pharmaceuticals used in the management of high cholesterol and chronic obstructive pulmonary disease (COPD). The distribution of social surplus between consumers and producers was also computed and the dynamics of rent extraction examined. Health-related social surplus increased consistently over time for both disease areas, mostly due to the launch of more effective technologies and a greater number of patients being treated for the conditions. However, the growth rate of social surplus differed for each disease and dissimilar patterns of distribution between consumer and producer surplus emerged across the years. For lipid-lowering therapies, yearly consumer surplus reaches 85 % of total health-related social surplus after the loss of exclusivity of major molecules, whilst for COPD it ranges from 54 to 69 %. Average producer surplus is approximately 25 % of total health-related social surplus in the lipid-lowering market between 1990 and 2010, and 37 % for COPD between 2001 and 2010. The share of surplus captured by non-innovative generic producers also varies differently across periods for both markets, reaching 11.12 % in the case of lipid-lowering therapies but just 1.55 % in the case of COPD. A considerable amount of the value may be recouped by consumers only towards the end of the lifecycle. Elements affecting the distribution of social surplus vary across disease areas and include the market pricing structure and the pattern of clinical effectiveness observed over time. The application of a longer-term disease specific perspective may be required when assessing the cost-effectiveness of health technologies at launch.

  18. Imaging in pleural mesothelioma: a review of the 11th International Conference of the International Mesothelioma Interest Group.

    PubMed

    Armato, Samuel G; Labby, Zacariah E; Coolen, Johan; Klabatsa, Astero; Feigen, Malcolm; Persigehl, Thorsten; Gill, Ritu R

    2013-11-01

    Imaging of malignant pleural mesothelioma (MPM) is essential to the diagnosis, assessment, and monitoring of this disease. The complex morphology and growth pattern of MPM, however, create unique challenges for image acquisition and interpretation. These challenges have captured the attention of investigators around the world, some of whom presented their work at the 2012 International Conference of the International Mesothelioma Interest Group (iMig 2012) in Boston, Massachusetts, USA, September 2012. The measurement of tumor thickness on computed tomography (CT) scans is the current standard of care in the assessment of MPM tumor response to therapy; in this context, variability among observers in the measurement task and in the tumor response classification categories derived from such measurements was reported. Alternate CT-based tumor response criteria, specifically direct measurement of tumor volume change and change in lung volume as a surrogate for tumor response, were presented. Dynamic contrast-enhanced CT has a role in other settings, but investigation into its potential use for imaging mesothelioma tumor perfusion only recently has been initiated. Magnetic resonance imaging (MRI) and positron-emission tomography (PET) are important imaging modalities in MPM and complement the information provided by CT. The pointillism sign in diffusion-weighted MRI was reported as a potential parameter for the classification of pleural lesions as benign or malignant, and PET parameters that measure tumor activity and functional tumor volume were presented as indicators of patient prognosis. Also reported was the use of PET/CT in the management of patients who undergo high-dose radiation therapy. Imaging for MPM impacts everything from initial patient diagnosis to the outcomes of clinical trials; iMig 2012 captured this broad range of imaging applications as investigators exploit technology and implement multidisciplinary approaches toward the benefit of MPM patients. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  19. Mapping PAM4 (clivatuzumab), a monoclonal antibody in clinical trials for early detection and therapy of pancreatic ductal adenocarcinoma, to MUC5AC mucin.

    PubMed

    Gold, David V; Newsome, Guy; Liu, Donglin; Goldenberg, David M

    2013-11-20

    PAM4, an antibody that has high specificity for pancreatic ductal adenocarcinoma (PDAC), compared to normal pancreas, benign lesions of the pancreas, and cancers originating from other tissues, is being investigated as a biomarker for early detection, as well as antibody-targeted imaging and therapy. Therefore, the identity of the antigen bound by this monoclonal antibody (MAb) can provide information leading to improved use of the antibody. Prior results suggested the antigen is a mucin-type glycoprotein rich in cysteine disulfide bridges that provide stable conformation for the PAM4-epitope. Indirect and sandwich enzyme immunoassays (EIA) were performed to compare and contrast the reactivity of PAM4 with several anti-mucin antibodies having known reactivity to specific mucin species (e.g., MUC1, MUC4, MUC5AC, etc.). Studies designed to block reactivity of PAM4 with its specific antigen also were performed. We demonstrate that MAbs 2-11 M1 and 45 M1, each reactive with MUC5AC, are able to provide signal in a heterologous sandwich immunoassay where PAM4 is the capture antibody. Further, we identify MAbs 21 M1, 62 M1, and 463 M1, each reactive with MUC5AC, as inhibiting the reaction of PAM4 with its specific epitope. MAbs directed to MUC1, MUC3, MUC4, MUC16 and CEACAM6 are not reactive with PAM4-captured antigen, nor are they able to block the reaction of PAM4 with its antigen. These data implicate MUC5AC as a specific mucin species to which PAM4 is reactive. Furthermore, this realization may allow for the improvement of the current PAM4 serum-based immunoassay for detection of early-stage PDAC by the application of anti-MUC5AC MAbs as probes in this sandwich EIA.

  20. Single photon detection imaging of Cherenkov light emitted during radiation therapy

    NASA Astrophysics Data System (ADS)

    Adamson, Philip M.; Andreozzi, Jacqueline M.; LaRochelle, Ethan; Gladstone, David J.; Pogue, Brian W.

    2018-03-01

    Cherenkov imaging during radiation therapy has been developed as a tool for dosimetry, which could have applications in patient delivery verification or in regular quality audit. The cameras used are intensified imaging sensors, either ICCD or ICMOS cameras, which allow important features of imaging, including: (1) nanosecond time gating, (2) amplification by 103-104, which together allow for imaging which has (1) real time capture at 10-30 frames per second, (2) sensitivity at the level of single photon event level, and (3) ability to suppress background light from the ambient room. However, the capability to achieve single photon imaging has not been fully analyzed to date, and as such was the focus of this study. The ability to quantitatively characterize how a single photon event appears in amplified camera imaging from the Cherenkov images was analyzed with image processing. The signal seen at normal gain levels appears to be a blur of about 90 counts in the CCD detector, after going through the chain of photocathode detection, amplification through a microchannel plate PMT, excitation onto a phosphor screen and then imaged on the CCD. The analysis of single photon events requires careful interpretation of the fixed pattern noise, statistical quantum noise distributions, and the spatial spread of each pulse through the ICCD.

  1. Simultaneous Ultrasound Therapy and Monitoring of Microbubble-Seeded Acoustic Cavitation Using a Single-Element Transducer.

    PubMed

    Heymans, Sophie V; Martindale, Christine F; Suler, Andrej; Pouliopoulos, Antonios N; Dickinson, Robert J; Choi, James J

    2017-08-01

    Ultrasound-driven microbubble (MB) activity is used in therapeutic applications such as blood clot dissolution and targeted drug delivery. The safety and performance of these technologies are linked to the type and distribution of MB activities produced within the targeted area, but controlling and monitoring these activities in vivo and in real time has proven to be difficult. As therapeutic pulses are often milliseconds long, MB monitoring currently requires a separate transducer used in a passive reception mode. Here, we present a simple, inexpensive, integrated setup, in which a focused single-element transducer can perform ultrasound therapy and monitoring simultaneously. MBs were made to flow through a vessel-mimicking tube, placed within the transducer's focus, and were sonicated with therapeutic pulses (peak rarefactional pressure: 75-827 kPa, pulse lengths: [Formula: see text] and 20 ms). The MB-seeded acoustic emissions were captured using the same transducer. The received signals were separated from the therapeutic signal with a hybrid coupler and a high-pass filter. We discriminated the MB-generated cavitation signal from the primary acoustic field and characterized MB behavior in real time. The simplicity and versatility of our circuit could make existing single-element therapeutic transducers also act as cavitation detectors, allowing the production of compact therapeutic systems with real time monitoring capabilities.

  2. Virtual reality applications to automated rendezvous and capture

    NASA Technical Reports Server (NTRS)

    Hale, Joseph; Oneil, Daniel

    1991-01-01

    Virtual Reality (VR) is a rapidly developing Human/Computer Interface (HCI) technology. The evolution of high-speed graphics processors and development of specialized anthropomorphic user interface devices, that more fully involve the human senses, have enabled VR technology. Recently, the maturity of this technology has reached a level where it can be used as a tool in a variety of applications. This paper provides an overview of: VR technology, VR activities at Marshall Space Flight Center (MSFC), applications of VR to Automated Rendezvous and Capture (AR&C), and identifies areas of VR technology that requires further development.

  3. 4DCAPTURE: a general purpose software package for capturing and analyzing two- and three-dimensional motion data acquired from video sequences

    NASA Astrophysics Data System (ADS)

    Walton, James S.; Hodgson, Peter; Hallamasek, Karen; Palmer, Jake

    2003-07-01

    4DVideo is creating a general purpose capability for capturing and analyzing kinematic data from video sequences in near real-time. The core element of this capability is a software package designed for the PC platform. The software ("4DCapture") is designed to capture and manipulate customized AVI files that can contain a variety of synchronized data streams -- including audio, video, centroid locations -- and signals acquired from more traditional sources (such as accelerometers and strain gauges.) The code includes simultaneous capture or playback of multiple video streams, and linear editing of the images (together with the ancilliary data embedded in the files). Corresponding landmarks seen from two or more views are matched automatically, and photogrammetric algorithms permit multiple landmarks to be tracked in two- and three-dimensions -- with or without lens calibrations. Trajectory data can be processed within the main application or they can be exported to a spreadsheet where they can be processed or passed along to a more sophisticated, stand-alone, data analysis application. Previous attempts to develop such applications for high-speed imaging have been limited in their scope, or by the complexity of the application itself. 4DVideo has devised a friendly ("FlowStack") user interface that assists the end-user to capture and treat image sequences in a natural progression. 4DCapture employs the AVI 2.0 standard and DirectX technology which effectively eliminates the file size limitations found in older applications. In early tests, 4DVideo has streamed three RS-170 video sources to disk for more than an hour without loss of data. At this time, the software can acquire video sequences in three ways: (1) directly, from up to three hard-wired cameras supplying RS-170 (monochrome) signals; (2) directly, from a single camera or video recorder supplying an NTSC (color) signal; and (3) by importing existing video streams in the AVI 1.0 or AVI 2.0 formats. The latter is particularly useful for high-speed applications where the raw images are often captured and stored by the camera before being downloaded. Provision has been made to synchronize data acquired from any combination of these video sources using audio and visual "tags." Additional "front-ends," designed for digital cameras, are anticipated.

  4. A network meta-analysis on the effects of information technology application on preoperative knowledge of patients.

    PubMed

    Lai, Yi-Horng

    2015-01-01

    The application of information technology in health education plan in Taiwan has existed for a long time. The purpose of this study is to explore the relationship between information technology application in health education and patients' preoperative knowledge by synthesizing existing researches that compare the effectiveness of information technology application and traditional instruction in the health education plan. In spite of claims regarding the potential benefits of using information technology in health education plan, results of previous researches were conflicting. This study is carried out to examine the effectiveness of information technology by using network meta-analysis, which is a statistical analysis of separate but similar studies in order to test the pooled data for statistical significance. Information technology application in health education discussed in this study include interactive technology therapy (person-computer), group interactive technology therapy (person-person), multimedia technology therapy and video therapy. The result has shown that group interactive technology therapy is the most effective, followed by interactive technology therapy. And these four therapies of information technology are all superior to the traditional health education plan (leaflet therapy).

  5. Carboranylporphyrins and uses thereof

    DOEpatents

    Wu, Haitao; Miura, Michiko

    2006-02-07

    The present invention is directed to low toxicity boronated compounds and methods for their use in the treatment, visualization, and diagnosis of tumors. More specifically, the present invention is directed to low toxicity carborane-containing 5, 10, 15, 20-tetraphenylporphyrin compounds and methods for their use particularly in boron neutron capture therapy (BNCT) and photodynamic therapy (PDT) for the treatment of tumors of the brain, head and neck, and surrounding tissue. The invention is also directed to using these carborane-containing tetraphenyl porphyrin compounds to methods of tumor imaging and/or diagnosis such as MRI, SPECT, or PET.

  6. Carboranylporphyrins and uses thereof

    DOEpatents

    Wu, Haitao; Miura, Michiko

    2006-01-24

    The present invention is directed to low toxicity boronated compounds and methods for their use in the treatment, visualization, and diagnosis of tumors. More specifically, the present invention is directed to low toxicity carborane-containing 5, 10, 15, 20-tetraphenylporphyrin compounds and methods for their use particularly in boron neutron capture therapy (BNCT) and photodynamic therapy (PDT) for the treatment of tumors of the brain, head, neck, and surrounding tissue. The invention is also directed to using these carborane-containing tetraphenyl porphyrin compounds to methods of tumor imaging and/or diagnosis such as MRI, SPECT, or PET.

  7. Study of Design Knowledge Capture (DKC) schemes implemented in magnetic bearing applications

    NASA Technical Reports Server (NTRS)

    1990-01-01

    A design knowledge capture (DKC) scheme was implemented using frame-based techniques. The objective of such a system is to capture not only the knowledge which describes a design, but also that which explains how the design decisions were reached. These knowledge types were labelled definitive and explanatory, respectively. Examination of the design process helped determine what knowledge to retain and at what stage that knowledge is used. A discussion of frames resulted in the recognition of their value to knowledge representation and organization. The FORMS frame system was used as a basis for further development, and for examples using magnetic bearing design. The specific contributions made by this research include: determination that frame-based systems provide a useful methodology for management and application of design knowledge; definition of specific user interface requirements, (this consists of a window-based browser); specification of syntax for DKC commands; and demonstration of the feasibility of DKC by applications to existing designs. It was determined that design knowledge capture could become an extremely valuable engineering tool for complicated, long-life systems, but that further work was needed, particularly the development of a graphic, window-based interface.

  8. Automatic satellite capture and berthing with robot arm (ASCABRA)

    NASA Technical Reports Server (NTRS)

    Inaba, Noriyasu; Wakabayashi, Yasufumi; Iijima, Takahiko

    1994-01-01

    The NASDA office of R&D is studying an automatic technique to capture and berth free-floating satellites using a robot arm on another satellite. A demonstration experiment plan with the Japanese engineering test satellite ETS-7 is being developed based on the basic research on the ground. The overview and key technologies of this experiment plan are presented, and future applications of the automatic capture technique are also reviewed.

  9. Design knowledge capture for the space station

    NASA Technical Reports Server (NTRS)

    Crouse, K. R.; Wechsler, D. B.

    1987-01-01

    The benefits of design knowledge availability are identifiable and pervasive. The implementation of design knowledge capture and storage using current technology increases the probability for success, while providing for a degree of access compatibility with future applications. The space station design definition should be expanded to include design knowledge. Design knowledge should be captured. A critical timing relationship exists between the space station development program, and the implementation of this project.

  10. INEL BNCT Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ackermann, A.L.

    1991-08-01

    This Bulletin presents a summary of accomplishments and highlights in the Idaho National Engineering Laboratory's (INEL) Boron Neutron Capture Therapy (BNCT) Program for August 1991. This bulletin includes information on the brain tumor and melanoma research programs, Power Burst Facility (PBF) technical support and modifications, PBF operations, and updates to the animal data charts.

  11. An algorithm for verifying biventricular capture based on evoked-response morphology.

    PubMed

    Diotallevi, Paolo; Ravazzi, Pier Antonio; Gostoli, Enrico; De Marchi, Giuseppe; Militello, Carmelo; Kraetschmer, Hannes

    2005-01-01

    Cardiac resynchronization therapy relies on consistent beat-by-beat myocardial capture in both ventricles. A pacemaker ensuring right (RV) and left ventricular (LV) capture through reliable capture verification and automatic output adjustment would contribute to patients' safety and quality of life. We studied the feasibility of an algorithm based on evoked-response (ER) morphology for capture verification in both the ventricles. RV and LV ER signals were recorded in 20 patients (mean age 72.5 years, range 64.3-80.4 years, 4 females and 16 males) during implantation of biventricular (BiV) pacing systems. Leads of several manufacturers were tested. Pacing and intracardiac electrogram (IEGM) recording were performed using an external pulse generator. IEGM and surface-lead electrocardiogram (ECG) signals were recorded under different pacing conditions for 10 seconds each: RV pacing only, LV pacing only, and BiV pacing with several interventricular delays. Based on morphology characteristics, ERs were classified manually for capture and failure to capture, and the validity of the classification was assessed by reference to the ECG. A total of 3,401 LV- and 3,345 RV-paced events were examined. In the RV and LV, the sensitivities of the algorithm were 95.6% and 96.1% in the RV and LV, respectively, and the corresponding specificities were 91.4% and 95.2%, respectively. The lower sensitivity in the RV was attributed to signal blanking in both channels during BiV pacing with a nonzero interventricular delay. The analysis revealed that the algorithm for identifying capture and failure to capture based on the ER-signal morphology was safe and effective in each ventricle with all leads tested in the study.

  12. Anodal right ventricular capture during left ventricular stimulation in CRT-implantable cardioverter defibrillators.

    PubMed

    Thibault, Bernard; Roy, Denis; Guerra, Peter G; Macle, Laurent; Dubuc, Marc; Gagné, Pierre; Greiss, Isabelle; Novak, Paul; Furlani, Aldo; Talajic, Mario

    2005-07-01

    Cardiac resynchronization therapy (CRT) has been shown to improve symptoms of patients with moderate to severe heart failure. Optimal CRT involves biventricular or left ventricular (LV) stimulation alone, atrio-ventricular (AV) delay optimization, and possibly interventricular timing adjustment. Recently, anodal capture of the right ventricle (RV) has been described for patients with CRT-pacemakers. It is unknown whether the same phenomenon exists in CRT systems associated with defibrillators (CRT-ICD). The RV leads used in these systems are different from pacemaker leads: they have a larger diameter and shocking coils, which may affect the occurrence of anodal capture. We looked for anodal RV capture during LV stimulation in 11 consecutive patients who received a CRT-ICD system with RV leads with a true bipolar design. Fifteen patients who had RV leads with an integrated design were used as controls. Anodal RV and LV thresholds were determined at pulse width (pw) durations of 0.2, 0.5, and 1.0 ms. RV anodal capture during LV pacing was found in 11/11 patients at some output with true bipolar RV leads versus 0/15 patients with RV leads with an integrated bipolar design. Anodal RV capture threshold was more affected by changes in pw duration than LV capture threshold. In CRT-ICD systems, RV leads with a true bipolar design with the proximal ring also used as the anode for LV pacing are associated with a high incidence of anodal RV capture during LV pacing. This may affect the clinical response to alternative resynchronization methods using single LV stimulation or interventricular delay programming.

  13. The calculation of neutron capture gamma-ray yields for space shielding applications

    NASA Technical Reports Server (NTRS)

    Yost, K. J.

    1972-01-01

    The application of nuclear models to the calculation of neutron capture and inelastic scattering gamma yields is discussed. The gamma ray cascade model describes the cascade process in terms of parameters which either: (1) embody statistical assumptions regarding electric and magnetic multipole transition strengths, level densities, and spin and parity distributions or (2) are fixed by experiment such as measured energies, spin and parity values, and transition probabilities for low lying states.

  14. The Application of Rational-Emotive Theory and Therapy to School-Aged Children.

    ERIC Educational Resources Information Center

    DiGiuseppe, Raymond; Bernard, Michael E.

    1990-01-01

    Explains rational-emotive theory and therapy and its applications to school psychology, highlighting distinction between disturbed and nondisturbed emotions and distinction between irrational and rational beliefs. Presents history of rational-emotive therapy and its application to emotional problems of children. Reviews research in…

  15. Neutron Capture Experiments Using the DANCE Array at Los Alamos

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dashdorj, D.; MonAme Scientific Research Center, Ulaanbaatar; Mitchell, G. E.

    2009-03-31

    The Detector for Advanced Neutron Capture Experiments (DANCE) is designed for neutron capture measurements on very small and/or radioactive targets. The DANCE array of 160 BaF{sub 2} scintillation detectors is located at the Lujan Center at the Los Alamos Neutron Science Center (LANSCE). Accurate measurements of neutron capture data are important for many current applications as well as for basic understanding of neutron capture. The gamma rays following neutron capture reactions have been studied by the time-of-flight technique using the DANCE array. The high granularity of the array allows measurements of the gamma-ray multiplicity. The gamma-ray multiplicities and energy spectramore » for different multiplicities can be measured and analyzed for spin and parity determination of the resolved resonances.« less

  16. Observation of IPL spectra using detector system incorporating broadband optical filters

    NASA Astrophysics Data System (ADS)

    Clarkson, D. McG.

    2007-07-01

    Systems using intense pulsed light are being increasingly used in therapy applications where issues related to safety of devices and also of performance are becoming more urgent to address. Mechanisms to address this include a suitable standards framework and also the development and application of appropriate measurement techniques. An approach of using conventional bandpass optical filters and silicon photodetectors has been implemented using an analogue USB data capture interfaces linked to a laptop PC. An initial system with 8 concurrent channels has been upgraded to a separate system sampling up to 16 analogue channels. Sampling takes place at the maximum hardware conversion rate of the USB device. Observations have been made of a range of intense pulsed light systems, including a Lumenis One unit with a range of discrete filters. The system has been of value in determining the basic parameters of output pulse profile and spectral composition. This has in turn been related to aspects of standards development for both device manufacture and allocation of appropriate safety eyewear. Initial assessments of a subset of intense pulsed light systems indicate significant complexities in terms, for example, of variation in spectral content as a function of device output setting.

  17. A smartphone application for psoriasis segmentation and classification (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Vasefi, Fartash; MacKinnon, Nicholas B.; Horita, Timothy; Shi, Kevin; Khan Munia, Tamanna Tabassum; Tavakolian, Kouhyar; Alhashim, Minhal; Fazel-Rezai, Reza

    2017-02-01

    Psoriasis is a chronic skin disease affecting approximately 125 million people worldwide. Currently, dermatologists monitor changes of psoriasis by clinical evaluation or by measuring psoriasis severity scores over time which lead to Subjective management of this condition. The goal of this paper is to develop a reliable assessment system to quantitatively assess the changes of erythema and intensity of scaling of psoriatic lesions. A smartphone deployable mobile application is presented that uses the smartphone camera and cloud-based image processing to analyze physiological characteristics of psoriasis lesions, identify the type and stage of the scaling and erythema. The application targets to automatically evaluate Psoriasis Area Severity Index (PASI) by measuring the severity and extent of psoriasis. The mobile application performs the following core functions: 1) it captures text information from user input to create a profile in a HIPAA compliant database. 2) It captures an image of the skin with psoriasis as well as image-related information entered by the user. 3) The application color correct the image based on environmental lighting condition using calibration process including calibration procedure by capturing Macbeth ColorChecker image. 4) The color-corrected image will be transmitted to a cloud-based engine for image processing. In cloud, first, the algorithm removes the non-skin background to ensure the psoriasis segmentation is only applied to the skin regions. Then, the psoriasis segmentation algorithm estimates the erythema and scaling boundary regions of lesion. We analyzed 10 images of psoriasis images captured by cellphone, determined PASI score for each subject during our pilot study, and correlated it with changes in severity scores given by dermatologists. The success of this work allows smartphone application for psoriasis severity assessment in a long-term treatment.

  18. Biological Gene Delivery Vehicles: Beyond Viral Vectors

    PubMed Central

    Seow, Yiqi; Wood, Matthew J

    2009-01-01

    Gene therapy covers a broad spectrum of applications, from gene replacement and knockdown for genetic or acquired diseases such as cancer, to vaccination, each with different requirements for gene delivery. Viral vectors and synthetic liposomes have emerged as the vehicles of choice for many applications today, but both have limitations and risks, including complexity of production, limited packaging capacity, and unfavorable immunological features, which restrict gene therapy applications and hold back the potential for preventive gene therapy. While continuing to improve these vectors, it is important to investigate other options, particularly nonviral biological agents which include bacteria, bacteriophage, virus-like particles (VLPs), erythrocyte ghosts, and exosomes. Exploiting the natural properties of these biological entities for specific gene delivery applications will expand the repertoire of gene therapy vectors available for clinical use. Here, we review the prospects for nonviral biological delivery vehicles as gene therapy agents with focus on their unique evolved biological properties and respective limitations and potential applications. The potential of these nonviral biological entities to act as clinical gene therapy delivery vehicles has already been shown in clinical trials using bacteria-mediated gene transfer and with sufficient development, these entities will complement the established delivery techniques for gene therapy applications. PMID:19277019

  19. Biological gene delivery vehicles: beyond viral vectors.

    PubMed

    Seow, Yiqi; Wood, Matthew J

    2009-05-01

    Gene therapy covers a broad spectrum of applications, from gene replacement and knockdown for genetic or acquired diseases such as cancer, to vaccination, each with different requirements for gene delivery. Viral vectors and synthetic liposomes have emerged as the vehicles of choice for many applications today, but both have limitations and risks, including complexity of production, limited packaging capacity, and unfavorable immunological features, which restrict gene therapy applications and hold back the potential for preventive gene therapy. While continuing to improve these vectors, it is important to investigate other options, particularly nonviral biological agents which include bacteria, bacteriophage, virus-like particles (VLPs), erythrocyte ghosts, and exosomes. Exploiting the natural properties of these biological entities for specific gene delivery applications will expand the repertoire of gene therapy vectors available for clinical use. Here, we review the prospects for nonviral biological delivery vehicles as gene therapy agents with focus on their unique evolved biological properties and respective limitations and potential applications. The potential of these nonviral biological entities to act as clinical gene therapy delivery vehicles has already been shown in clinical trials using bacteria-mediated gene transfer and with sufficient development, these entities will complement the established delivery techniques for gene therapy applications.

  20. On-orbit demonstration of automated closure and capture using ESA-developed proximity operations technologies and an existing, serviceable NASA Explorer Platform spacecraft

    NASA Technical Reports Server (NTRS)

    Hohwiesner, Bill; Claudinon, Bernard

    1991-01-01

    The European Space Agency (ESA) has been working to develop an autonomous rendezvous and docking capability since 1984 to enable Hermes to automatically dock with Columbus. As a result, ESA with Matra, MBB, and other space companies have developed technologies that are also directly supportive of the current NASA initiative for Automated Rendezvous and Capture. Fairchild and Matra would like to discuss the results of the applicable ESA/Matra rendezvous and capture developments, and suggest how these capabilities could be used, together with an existing NASA Explorer Platform satellite, to minimize new development and accomplish a cost effective automatic closure and capture demonstration program. Several RV sensors have been developed at breadboard level for the Hermes/Columbus program by Matra, MBB, and SAAB. Detailed algorithms for automatic rendezvous, closure, and capture have been developed by ESA and CNES for application with Hermes to Columbus rendezvous and docking, and they currently are being verified with closed-loop software simulation. The algorithms have multiple closed-loop control modes and phases starting at long range using GPS navigation. Differential navigation is used for coast/continuous thrust homing, holdpoint acquisition, V-bar hopping, and station point acquisition. The proximity operation sensor is used for final closure and capture. A subset of these algorithms, comprising the proximity operations algorithms, could easily be extracted and tailored to a limited objective closure and capture flight demonstration.

  1. Rapid differentiation of rocky mountain spotted fever from chickenpox, measles, and enterovirus infections and bacterial meningitis by frequency-pulsed electron capture gas-liquid chromatographic analysis of sera.

    PubMed Central

    Brooks, J B; McDade, J E; Alley, C C

    1981-01-01

    Normal sera and sera from patients with Rocky Mountain spotted fever, chickenpox, enterovirus infections, measles, and Neisseria meningitidis infections were extracted with organic solvents under acidic and basic conditions and then derivatized with trichloroethanol or heptafluorobutyric anhydride-ethanol to form electron-capturing derivatives of organic acids, alcohols, and amines. The derivatives were analyzed by frequency-pulsed electron capture gas-liquid chromatography (FPEC-GLC). There were unique differences in the FPEC-GLC profiles of sera obtained from patients with these respective diseases. With Rocky Mountain spotted fever patients, typical profiles were detected as early as 1 day after onset of disease and before antibody could be detected in the serum. Rapid diagnosis of Rocky Mountain spotted fever by FPEC-GLC could permit early and effective therapy, thus preventing many deaths from this disease. PMID:7276147

  2. Prompt gamma and neutron detection in BNCT utilizing a CdTe detector.

    PubMed

    Winkler, Alexander; Koivunoro, Hanna; Reijonen, Vappu; Auterinen, Iiro; Savolainen, Sauli

    2015-12-01

    In this work, a novel sensor technology based on CdTe detectors was tested for prompt gamma and neutron detection using boronated targets in (epi)thermal neutron beam at FiR1 research reactor in Espoo, Finland. Dedicated neutron filter structures were omitted to enable simultaneous measurement of both gamma and neutron radiation at low reactor power (2.5 kW). Spectra were collected and analyzed in four different setups in order to study the feasibility of the detector to measure 478 keV prompt gamma photons released from the neutron capture reaction of boron-10. The detector proved to have the required sensitivity to detect and separate the signals from both boron neutron and cadmium neutron capture reactions, which makes it a promising candidate for monitoring the spatial and temporal development of in vivo boron distribution in boron neutron capture therapy. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Capturing, Harmonizing and Delivering Data and Quality Provenance

    NASA Technical Reports Server (NTRS)

    Leptoukh, Gregory; Lynnes, Christopher

    2011-01-01

    Satellite remote sensing data have proven to be vital for various scientific and applications needs. However, the usability of these data depends not only on the data values but also on the ability of data users to assess and understand the quality of these data for various applications and for comparison or inter-usage of data from different sensors and models. In this paper, we describe some aspects of capturing, harmonizing and delivering this information to users in the framework of distributed web-based data tools.

  4. Computational cameras for moving iris recognition

    NASA Astrophysics Data System (ADS)

    McCloskey, Scott; Venkatesha, Sharath

    2015-05-01

    Iris-based biometric identification is increasingly used for facility access and other security applications. Like all methods that exploit visual information, however, iris systems are limited by the quality of captured images. Optical defocus due to a small depth of field (DOF) is one such challenge, as is the acquisition of sharply-focused iris images from subjects in motion. This manuscript describes the application of computational motion-deblurring cameras to the problem of moving iris capture, from the underlying theory to system considerations and performance data.

  5. Applied research of embedded WiFi technology in the motion capture system

    NASA Astrophysics Data System (ADS)

    Gui, Haixia

    2012-04-01

    Embedded wireless WiFi technology is one of the current wireless hot spots in network applications. This paper firstly introduces the definition and characteristics of WiFi. With the advantages of WiFi such as using no wiring, simple operation and stable transmission, this paper then gives a system design for the application of embedded wireless WiFi technology in the motion capture system. Also, it verifies the effectiveness of design in the WiFi-based wireless sensor hardware and software program.

  6. Preparation Methods of Metal Organic Frameworks and Their Capture of CO2

    NASA Astrophysics Data System (ADS)

    Zhang, Linjian; Liand, Fangqin; Luo, Liangfei

    2018-01-01

    The increasingly serious greenhouse effect makes people pay more attention to the capture and storage technology of CO2. Metal organic frameworks (MOFs) have the advantages of high specific surface area, porous structure and controllable structure, and become the research focus of CO2 emission reduction technology in recent years. In this paper, the characteristics, preparation methods and application of MOFs in the field of CO2 adsorption and separation are discussed, especially the application of flue gas environment in power plants.

  7. Enhanced Cell Capture on Functionalized Graphene Oxide Nanosheets through Oxygen Clustering.

    PubMed

    Bardhan, Neelkanth M; Kumar, Priyank V; Li, Zeyang; Ploegh, Hidde L; Grossman, Jeffrey C; Belcher, Angela M; Chen, Guan-Yu

    2017-02-28

    With the global rise in incidence of cancer and infectious diseases, there is a need for the development of techniques to diagnose, treat, and monitor these conditions. The ability to efficiently capture and isolate cells and other biomolecules from peripheral whole blood for downstream analyses is a necessary requirement. Graphene oxide (GO) is an attractive template nanomaterial for such biosensing applications. Favorable properties include its two-dimensional architecture and wide range of functionalization chemistries, offering significant potential to tailor affinity toward aromatic functional groups expressed in biomolecules of interest. However, a limitation of current techniques is that as-synthesized GO nanosheets are used directly in sensing applications, and the benefits of their structural modification on the device performance have remained unexplored. Here, we report a microfluidic-free, sensitive, planar device on treated GO substrates to enable quick and efficient capture of Class-II MHC-positive cells from murine whole blood. We achieve this by using a mild thermal annealing treatment on the GO substrates, which drives a phase transformation through oxygen clustering. Using a combination of experimental observations and MD simulations, we demonstrate that this process leads to improved reactivity and density of functionalization of cell capture agents, resulting in an enhanced cell capture efficiency of 92 ± 7% at room temperature, almost double the efficiency afforded by devices made using as-synthesized GO (54 ± 3%). Our work highlights a scalable, cost-effective, general approach to improve the functionalization of GO, which creates diverse opportunities for various next-generation device applications.

  8. A real-time 3D end-to-end augmented reality system (and its representation transformations)

    NASA Astrophysics Data System (ADS)

    Tytgat, Donny; Aerts, Maarten; De Busser, Jeroen; Lievens, Sammy; Rondao Alface, Patrice; Macq, Jean-Francois

    2016-09-01

    The new generation of HMDs coming to the market is expected to enable many new applications that allow free viewpoint experiences with captured video objects. Current applications usually rely on 3D content that is manually created or captured in an offline manner. In contrast, this paper focuses on augmented reality applications that use live captured 3D objects while maintaining free viewpoint interaction. We present a system that allows live dynamic 3D objects (e.g. a person who is talking) to be captured in real-time. Real-time performance is achieved by traversing a number of representation formats and exploiting their specific benefits. For instance, depth images are maintained for fast neighborhood retrieval and occlusion determination, while implicit surfaces are used to facilitate multi-source aggregation for both geometry and texture. The result is a 3D reconstruction system that outputs multi-textured triangle meshes at real-time rates. An end-to-end system is presented that captures and reconstructs live 3D data and allows for this data to be used on a networked (AR) device. For allocating the different functional blocks onto the available physical devices, a number of alternatives are proposed considering the available computational power and bandwidth for each of the components. As we will show, the representation format can play an important role in this functional allocation and allows for a flexible system that can support a highly heterogeneous infrastructure.

  9. Cardiovascular Stress During Inpatient Spinal Cord Injury Rehabilitation.

    PubMed

    Zbogar, Dominik; Eng, Janice J; Noble, Jeremy W; Miller, William C; Krassioukov, Andrei V; Verrier, Mary C

    2017-12-01

    (1) To measure the amount of cardiovascular stress, self-reported physical activity, and accelerometry-measured physical activity by individuals with spinal cord injury (SCI) during physical therapy (PT) and occupational therapy (OT); and (2) to investigate the relations between these measures. Observational study. Two inpatient SCI rehabilitation centers. Patients with SCI (N=87) were recruited from consecutive admissions to rehabilitation. Not applicable. Heart rate was recorded by a Holter monitor, whereas physical activity was captured by self-report (Physical Activity Recall Assessment for People with SCI questionnaire) and real-time wrist accelerometry during a total of 334 PT and OT inpatient sessions. Differences between individuals with paraplegia and tetraplegia were assessed via Mann-Whitney U tests. Spearman correlations were used to explore the relation between measurements of physical activity and heart rate. Time spent at a heart rate within a cardiovascular training zone (≥40% heart rate reserve) was low and did not exceed a median of 5 minutes. In contrast, individuals reported at least 60 minutes of higher-intensity time during therapy. There was a low but statistically significant correlation between all measures. The cardiovascular stress incurred by individuals with SCI during inpatient PT and OT sessions is low and not sufficient to obtain a cardiovascular training effect to optimize their neurologic, cardiovascular, or musculoskeletal health; this represents a lost opportunity to maximize rehabilitation. Self-reported minutes of higher-intensity physical activity do not reflect actual time spent at a higher intensity measured objectively via a heart rate monitor. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  10. Upper-limb kinematic reconstruction during stroke robot-aided therapy.

    PubMed

    Papaleo, E; Zollo, L; Garcia-Aracil, N; Badesa, F J; Morales, R; Mazzoleni, S; Sterzi, S; Guglielmelli, E

    2015-09-01

    The paper proposes a novel method for an accurate and unobtrusive reconstruction of the upper-limb kinematics of stroke patients during robot-aided rehabilitation tasks with end-effector machines. The method is based on a robust analytic procedure for inverse kinematics that simply uses, in addition to hand pose data provided by the robot, upper arm acceleration measurements for computing a constraint on elbow position; it is exploited for task space augmentation. The proposed method can enable in-depth comprehension of planning strategy of stroke patients in the joint space and, consequently, allow developing therapies tailored for their residual motor capabilities. The experimental validation has a twofold purpose: (1) a comparative analysis with an optoelectronic motion capturing system is used to assess the method capability to reconstruct joint motion; (2) the application of the method to healthy and stroke subjects during circle-drawing tasks with InMotion2 robot is used to evaluate its efficacy in discriminating stroke from healthy behavior. The experimental results have shown that arm angles are reconstructed with a RMSE of 8.3 × 10(-3) rad. Moreover, the comparison between healthy and stroke subjects has revealed different features in the joint space in terms of mean values and standard deviations, which also allow assessing inter- and intra-subject variability. The findings of this study contribute to the investigation of motor performance in the joint space and Cartesian space of stroke patients undergoing robot-aided therapy, thus allowing: (1) evaluating the outcomes of the therapeutic approach, (2) re-planning the robotic treatment based on patient needs, and (3) understanding pathology-related motor strategies.

  11. An overview of CAFE credits and incorporation of the benefits of on-board carbon capture.

    DOT National Transportation Integrated Search

    2014-05-01

    This report discusses the application of Corporate Average Fuel Economy (CAFE) : credits that are currently available to vehicle manufacturers in the U.S., and the implications of : on-board carbon capture and sequestration (on-board CCS) on fu...

  12. Reduction of lunar landing fuel requirements by utilizing lunar ballistic capture.

    PubMed

    Johnson, Michael D; Belbruno, Edward A

    2005-12-01

    Ballistic lunar capture trajectories have been successfully utilized for lunar orbital missions since 1991. Recent interest in lunar landing trajectories has occurred due to a directive from President Bush to return humans to the Moon by 2015. NASA requirements for humans to return to the lunar surface include separation of crew and cargo missions, all lunar surface access, and anytime-abort to return to Earth. Such requirements are very demanding from a propellant standpoint. The subject of this paper is the application of lunar ballistic capture for the reduction of lunar landing propellant requirements. Preliminary studies of the application of weak stability boundary (WSB) trajectories and ballistic capture have shown that considerable savings in low Earth orbit (LEO) mission mass may be realized, on the order of 36% less than conventional Hohmann transfer orbit missions. Other advantages, such as reduction in launch window constraints and reduction of lunar orbit maintenance propellant requirements, have also surfaced from this study.

  13. Application of halloysite nanotubes for carbon dioxide capture

    NASA Astrophysics Data System (ADS)

    Kim, Jinsoo; Rubino, Ilaria; Lee, Joo-Youp; Choi, Hyo-Jick

    2016-04-01

    Halloysite is a naturally occurring clay, with physical structure represented by halloysite nanotubes (HNTs). We investigated the potential applicability of HNTs for carbon dioxide (CO2) capture, using two amine-functionalized HNTs: (3-aminopropyl) triethoxysilane (APTES)-grafted HNTs and polyethylenimine (PEI)-impregnated HNTs. APTES-HNTs and PEI-HNTs resulted in 5.6 and 30 wt. % (in sorbent) in functionalization onto HNTs, respectively. Capture efficiency was higher in APTES-HNTs at lower temperatures, while it was maximum in PEI-HNTs at 70°C-75 °C. At 75 °C, adsorption/desorption tests showed that 95% of the two reactions occurred within 30 min, and exhibited 0.15 and 0.21 millimole of CO2 adsorption capacity per millimole of amine group for APTES-HNTs and PEI-HNTs, respectively. During 10 cycles of CO2 adsorption/desorption, there was no significant decrease in sorbent weight and adsorption capacity in both HNTs. These results show that inherent structural features of HNTs can be easily tailored for the development of operational condition-specific CO2 capture system.

  14. Economics of fluid therapy in critically ill patients.

    PubMed

    Lyu, Peter F; Murphy, David J

    2014-08-01

    Fluid therapy practices are an ongoing debate in critical care as evidence continues to emerge on the clinical effectiveness of different fluids and regimens. Although fluid therapy is a frequent and often costly treatment in the ICU, cost considerations have been largely absent from these studies. To facilitate a more structured approach to understanding fluid therapy costs and their role in clinical practice, we summarize currently available options and describe a framework for identifying and organizing relevant costs. Fluid therapy is a complex area of care that has been rarely studied from a cost-effectiveness perspective. We identify seven cost areas that capture fluid therapy-related costs during preutilization, point-of-utilization, and postutilization periods. These costs are driven by decisions on the type of fluid and administration strategy. Although estimates for some cost areas could be informed by medical literature, other cost areas remain unclear and require further investigation. Given the growing emphasis on the value of care, providers must recognize the important cost consequences of clinical decisions in fluid therapy. Future research into fluid therapy costs is needed and can be guided by this framework. Developing a complete cost picture is an initial and necessary step for improving values for patients, hospitals, and healthcare systems.

  15. A quartz nanopillar hemocytometer for high-yield separation and counting of CD4+ T lymphocytes

    NASA Astrophysics Data System (ADS)

    Kim, Dong-Joo; Seol, Jin-Kyeong; Wu, Yu; Ji, Seungmuk; Kim, Gil-Sung; Hyung, Jung-Hwan; Lee, Seung-Yong; Lim, Hyuneui; Fan, Rong; Lee, Sang-Kwon

    2012-03-01

    We report the development of a novel quartz nanopillar (QNP) array cell separation system capable of selectively capturing and isolating a single cell population including primary CD4+ T lymphocytes from the whole pool of splenocytes. Integrated with a photolithographically patterned hemocytometer structure, the streptavidin (STR)-functionalized-QNP (STR-QNP) arrays allow for direct quantitation of captured cells using high content imaging. This technology exhibits an excellent separation yield (efficiency) of ~95.3 +/- 1.1% for the CD4+ T lymphocytes from the mouse splenocyte suspensions and good linear response for quantitating captured CD4+ T-lymphoblasts, which is comparable to flow cytometry and outperforms any non-nanostructured surface capture techniques, i.e. cell panning. This nanopillar hemocytometer represents a simple, yet efficient cell capture and counting technology and may find immediate applications for diagnosis and immune monitoring in the point-of-care setting.We report the development of a novel quartz nanopillar (QNP) array cell separation system capable of selectively capturing and isolating a single cell population including primary CD4+ T lymphocytes from the whole pool of splenocytes. Integrated with a photolithographically patterned hemocytometer structure, the streptavidin (STR)-functionalized-QNP (STR-QNP) arrays allow for direct quantitation of captured cells using high content imaging. This technology exhibits an excellent separation yield (efficiency) of ~95.3 +/- 1.1% for the CD4+ T lymphocytes from the mouse splenocyte suspensions and good linear response for quantitating captured CD4+ T-lymphoblasts, which is comparable to flow cytometry and outperforms any non-nanostructured surface capture techniques, i.e. cell panning. This nanopillar hemocytometer represents a simple, yet efficient cell capture and counting technology and may find immediate applications for diagnosis and immune monitoring in the point-of-care setting. Electronic supplementary information (ESI) available. See DOI: 10.1039/c2nr11338d

  16. Identification of a putative protein profile associated with tamoxifen therapy resistance in breast cancer.

    PubMed

    Umar, Arzu; Kang, Hyuk; Timmermans, Annemieke M; Look, Maxime P; Meijer-van Gelder, Marion E; den Bakker, Michael A; Jaitly, Navdeep; Martens, John W M; Luider, Theo M; Foekens, John A; Pasa-Tolić, Ljiljana

    2009-06-01

    Tamoxifen resistance is a major cause of death in patients with recurrent breast cancer. Current clinical factors can correctly predict therapy response in only half of the treated patients. Identification of proteins that are associated with tamoxifen resistance is a first step toward better response prediction and tailored treatment of patients. In the present study we intended to identify putative protein biomarkers indicative of tamoxifen therapy resistance in breast cancer using nano-LC coupled with FTICR MS. Comparative proteome analysis was performed on approximately 5,500 pooled tumor cells (corresponding to approximately 550 ng of protein lysate/analysis) obtained through laser capture microdissection (LCM) from two independently processed data sets (n = 24 and n = 27) containing both tamoxifen therapy-sensitive and therapy-resistant tumors. Peptides and proteins were identified by matching mass and elution time of newly acquired LC-MS features to information in previously generated accurate mass and time tag reference databases. A total of 17,263 unique peptides were identified that corresponded to 2,556 non-redundant proteins identified with > or = 2 peptides. 1,713 overlapping proteins between the two data sets were used for further analysis. Comparative proteome analysis revealed 100 putatively differentially abundant proteins between tamoxifen-sensitive and tamoxifen-resistant tumors. The presence and relative abundance for 47 differentially abundant proteins were verified by targeted nano-LC-MS/MS in a selection of unpooled, non-microdissected discovery set tumor tissue extracts. ENPP1, EIF3E, and GNB4 were significantly associated with progression-free survival upon tamoxifen treatment for recurrent disease. Differential abundance of our top discriminating protein, extracellular matrix metalloproteinase inducer, was validated by tissue microarray in an independent patient cohort (n = 156). Extracellular matrix metalloproteinase inducer levels were higher in therapy-resistant tumors and significantly associated with an earlier tumor progression following first line tamoxifen treatment (hazard ratio, 1.87; 95% confidence interval, 1.25-2.80; p = 0.002). In summary, comparative proteomics performed on laser capture microdissection-derived breast tumor cells using nano-LC-FTICR MS technology revealed a set of putative biomarkers associated with tamoxifen therapy resistance in recurrent breast cancer.

  17. DynAMo: A Modular Platform for Monitoring Process, Outcome, and Algorithm-Based Treatment Planning in Psychotherapy

    PubMed Central

    Laireiter, Anton Rupert

    2017-01-01

    Background In recent years, the assessment of mental disorders has become more and more personalized. Modern advancements such as Internet-enabled mobile phones and increased computing capacity make it possible to tap sources of information that have long been unavailable to mental health practitioners. Objective Software packages that combine algorithm-based treatment planning, process monitoring, and outcome monitoring are scarce. The objective of this study was to assess whether the DynAMo Web application can fill this gap by providing a software solution that can be used by both researchers to conduct state-of-the-art psychotherapy process research and clinicians to plan treatments and monitor psychotherapeutic processes. Methods In this paper, we report on the current state of a Web application that can be used for assessing the temporal structure of mental disorders using information on their temporal and synchronous associations. A treatment planning algorithm automatically interprets the data and delivers priority scores of symptoms to practitioners. The application is also capable of monitoring psychotherapeutic processes during therapy and of monitoring treatment outcomes. This application was developed using the R programming language (R Core Team, Vienna) and the Shiny Web application framework (RStudio, Inc, Boston). It is made entirely from open-source software packages and thus is easily extensible. Results The capabilities of the proposed application are demonstrated. Case illustrations are provided to exemplify its usefulness in clinical practice. Conclusions With the broad availability of Internet-enabled mobile phones and similar devices, collecting data on psychopathology and psychotherapeutic processes has become easier than ever. The proposed application is a valuable tool for capturing, processing, and visualizing these data. The combination of dynamic assessment and process- and outcome monitoring has the potential to improve the efficacy and effectiveness of psychotherapy. PMID:28729233

  18. Regulatory landscape for cell therapy--EU view.

    PubMed

    McBlane, James W

    2015-09-01

    This article addresses regulation of cell therapies in the European Union (EU), covering cell sourcing and applications for clinical trials and marketing authorisation applications. Regulatory oversight of cell sourcing and review of applications for clinical trials with cell therapies are handled at national level, that is, separately with each country making its own decisions. For clinical trials, this can lead to different decisions in different countries for the same trial. A regulation is soon to come into force that will address this and introduce a more efficient clinical trial application process. However, at the marketing authorisation stage, the process is pan-national: the Committee for Human Medicinal Products (CHMP) is responsible for giving the final scientific opinion on all EU marketing authorisation applications for cell therapies: favourable scientific opinions are passed to the European Commission (EC) for further consultation and, if successful, grant of a marketing authorisation valid in all 28 EU countries. In its review of applications for marketing authorisations (MAAs) for cell therapies, the CHMP is obliged to consult the Committee for Advanced Therapies (CAT), who conduct detailed scientific assessments of these applications, with assessment by staff from national regulatory authorities and specialist advisors to the regulators. Copyright © 2015.

  19. A CAT scan for cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2009-01-01

    Recently, a team of scientists from Berkeley Lab, Stanford University, and the University of California, San Francisco used Berkeley Lab's National Center for X-ray Tomography to capture the changes that occur when Candida albicans is exposed to a new and promising antifungal therapy. http://newscenter.lbl.gov/feature-stories/2009/12/10/cat-scan-cells/

  20. Boron-containing amino carboxylic acid compounds and uses thereof

    DOEpatents

    Kabalka, George W.; Srivastava, Rajiv R.

    2000-03-14

    Novel compounds which are useful for boron neutron capture therapy (BNCT) are disclosed. The compounds comprise a stable boron-containing group and an aminocycloalkane carboxylic acid group or a boronated acyclic hydrocarbon-linked amino carboxylic acid. Methods for synthesis of the compounds and for use of the compounds in BNCT are disclosed.

  1. INEL BNCT Program: Volume 5, No. 9

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ackermann, A.L.

    1991-01-01

    This Bulletin presents a summary of accomplishments and highlights of the Idaho National Engineering Laboratory's (INEL) Boron Neutron Capture Therapy (BNCT) Program for September 1991. This bulletin includes information on the brain tumor and melanoma research programs, Power Burst Facility (PBF) technical support and modifications, PBF operations, and updates to the animal data charts.

  2. Filipino Arts among Elders in Institutionalized Care Settings

    ERIC Educational Resources Information Center

    de Guzman, Allan B.; Satuito, James Cyril B.; Satumba, Miko Anne E.; Segui, Diego Rey A.; Serquina, Faith Evelyn C.; Serrano, Lawrence Jan P.; Sevilla, Madelyn D.

    2011-01-01

    The use of traditional art in recreational therapies is unexplored. This paper, thus, attempts to surface the unique power of traditional Filipino arts (TFA) as synergizing lens in capturing the individual and the collective experiences of a select group of Filipino elderly in an institutionalized care setting relative to their feelings of…

  3. Targeting glioma stem cells enhances anti-tumor effect of boron neutron capture therapy

    PubMed Central

    Sun, Ting; Li, Yanyan; Huang, Yulun; Zhang, Zizhu; Yang, Weilian; Du, Ziwei; Zhou, Youxin

    2016-01-01

    The uptake of (10)boron by tumor cells plays an important role for cell damage in boron neutron capture therapy (BNCT). CD133 is frequently expressed in the membrane of glioma stem cells (GSCs), resistant to radiotherapy and chemotherapy, and represents a potential therapeutic target. To increase (10)boron uptake in GSCs, we created a polyamido amine dendrimer, conjugated CD133 monoclonal antibodies, encapsulating mercaptoundecahydrododecaborate (BSH) in void spaces, and monitored the uptake of the bioconjugate nanoparticles by GSCs in vitro and in vivo. Fluorescence microscopy showed the specific uptake of the bioconjugate nanoparticles by CD133-positive GSCs. Treatment with the biconjugate nanoparticles resulted in a significant lethal effect after neutron radiation due to efficient and CD133-independent cellular targeting and uptake in CD133-expressing GSCs. A significantly longer survival occurred in combination with the biconjugate nanoparticles and BSH compared with BSH alone in human intracranial GBM models employing CD133-positive GSCs xenografts. Our data demonstrated that this bioconjugate nanoparticle targets human CD133-positive GSCs and is a potential boron agent in BNCT. PMID:27191269

  4. Gyrotron-driven high current ECR ion source for boron-neutron capture therapy neutron generator

    NASA Astrophysics Data System (ADS)

    Skalyga, V.; Izotov, I.; Golubev, S.; Razin, S.; Sidorov, A.; Maslennikova, A.; Volovecky, A.; Kalvas, T.; Koivisto, H.; Tarvainen, O.

    2014-12-01

    Boron-neutron capture therapy (BNCT) is a perspective treatment method for radiation resistant tumors. Unfortunately its development is strongly held back by a several physical and medical problems. Neutron sources for BNCT currently are limited to nuclear reactors and accelerators. For wide spread of BNCT investigations more compact and cheap neutron source would be much more preferable. In present paper an approach for compact D-D neutron generator creation based on a high current ECR ion source is suggested. Results on dense proton beams production are presented. A possibility of ion beams formation with current density up to 600 mA/cm2 is demonstrated. Estimations based on obtained experimental results show that neutron target bombarded by such deuteron beams would theoretically yield a neutron flux density up to 6·1010 cm-2/s. Thus, neutron generator based on a high-current deuteron ECR source with a powerful plasma heating by gyrotron radiation could fulfill the BNCT requirements significantly lower price, smaller size and ease of operation in comparison with existing reactors and accelerators.

  5. Targeting glioma stem cells enhances anti-tumor effect of boron neutron capture therapy.

    PubMed

    Sun, Ting; Li, Yanyan; Huang, Yulun; Zhang, Zizhu; Yang, Weilian; Du, Ziwei; Zhou, Youxin

    2016-07-12

    The uptake of (10)boron by tumor cells plays an important role for cell damage in boron neutron capture therapy (BNCT). CD133 is frequently expressed in the membrane of glioma stem cells (GSCs), resistant to radiotherapy and chemotherapy, and represents a potential therapeutic target. To increase (10)boron uptake in GSCs, we created a polyamido amine dendrimer, conjugated CD133 monoclonal antibodies, encapsulating mercaptoundecahydrododecaborate (BSH) in void spaces, and monitored the uptake of the bioconjugate nanoparticles by GSCs in vitro and in vivo. Fluorescence microscopy showed the specific uptake of the bioconjugate nanoparticles by CD133-positive GSCs. Treatment with the biconjugate nanoparticles resulted in a significant lethal effect after neutron radiation due to efficient and CD133-independent cellular targeting and uptake in CD133-expressing GSCs. A significantly longer survival occurred in combination with the biconjugate nanoparticles and BSH compared with BSH alone in human intracranial GBM models employing CD133-positive GSCs xenografts. Our data demonstrated that this bioconjugate nanoparticle targets human CD133-positive GSCs and is a potential boron agent in BNCT.

  6. Influence of p53 status on the effects of boron neutron capture therapy in glioblastoma.

    PubMed

    Seki, Keiko; Kinashi, Yuko; Takahashi, Sentaro

    2015-01-01

    The tumor suppressor gene p53 is mutated in glioblastoma. We studied the relationship between the p53 gene and the biological effects of boron neutron capture therapy (BNCT). The human glioblastoma cells; A172, expressing wild-type p53, and T98G, with mutant p53, were irradiated by the Kyoto University Research Reactor (KUR). The biological effects after neutron irradiation were evaluated by the cell killing effect, 53BP1 foci assay and apoptosis induction. The survival-fraction data revealed that A172 was more radiosensitive than T98G, but the difference was reduced when boronophenylalanine (BPA) was present. Both cell lines exhibited similar numbers of foci, suggesting that the initial levels of DNA damage did not depend on p53 function. Detection of apoptosis revealed a lower rate of apoptosis in the T98G. BNCT causes cell death in glioblastoma cells, regardless of p53 mutation status. In T98G cells, cell killing and apoptosis occurred effectively following BNCT. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  7. Lithium Nitride Synthesized by in situ Lithium Deposition and Ion Implantation for Boron Neutron Capture Therapy

    NASA Astrophysics Data System (ADS)

    Ishitama, Shintaro; Baba, Yuji; Fujii, Ryo; Nakamura, Masaru; Imahori, Yoshio

    Li3N synthesis on Li deposition layer was conducted without H2O and O2 by in situ lithium deposition in high vacuum chamber of 10-6 Pa and ion implantation techniques and the thermo-chemical stability of the Li3N/Li/Cu tri-layered target for Boron Neutron Capture Therapy (BNCT) under laser heating and air exposure was characterized by X-ray photoelectron spectroscopy (XPS). Following conclusions were derived; (1) Li3N/Li/Cu tri-layered target with very low oxide and carbon contamination was synthesized by in situ lithium vacuum deposition and N2+ ion implantation without H2O and O2 additions, (2) The starting temperature of evaporation of Li3N/Li/Cu tri-layered target increased by 120K compared to that of the Li/Cu target and (3) Remarkable oxidation and carbon contamination were observed on the surface of Li3N/Li/Cu after air exposure and these contaminated compositions was not removed by Ar+ heavy sputtering.

  8. The accelerator neutron source for boron neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Kasatov, D.; Koshkarev, A.; Kuznetsov, A.; Makarov, A.; Ostreinov, Yu; Shchudlo, I.; Sorokin, I.; Sycheva, T.; Taskaev, S.; Zaidi, L.

    2016-11-01

    The accelerator based epithermal neutron source for Boron Neutron Capture Therapy (BNCT) is proposed, created and used in the Budker Institute of Nuclear Physics. In 2014, with the support of the Russian Science Foundation created the BNCT laboratory for the purpose to the end of 2016 get the neutron flux, suitable for BNCT. For getting 3 mA 2.3 MeV proton beam, was created a new type accelerator - tandem accelerator with vacuum isolation. On this moment, we have a stationary proton beam with 2.3 MeV and current 1.75 mA. Generation of neutrons is carried out by dropping proton beam on to lithium target as a result of threshold reaction 7Li(p,n)7Be. Established facility is a unique scientific installation. It provides a generating of neutron flux, including a monochromatic energy neutrons, gamma radiation, alpha-particles and positrons, and may be used by other research groups for carrying out scientific researches. The article describes an accelerator neutron source, presents and discusses the result of experiments and declares future plans.

  9. MAGIC polymer gel for dosimetric verification in boron neutron capture therapy

    PubMed Central

    Heikkinen, Sami; Kotiluoto, Petri; Serén, Tom; Seppälä, Tiina; Auterinen, Iiro; Savolainen, Sauli

    2007-01-01

    Radiation‐sensitive polymer gels are among the most promising three‐dimensional dose verification tools developed to date. We tested the normoxic polymer gel dosimeter known by the acronym MAGIC (methacrylic and ascorbic acid in gelatin initiated by copper) to evaluate its use in boron neutron capture therapy (BNCT) dosimetry. We irradiated a large cylindrical gel phantom (diameter: 10 cm; length: 20 cm) in the epithermal neutron beam of the Finnish BNCT facility at the FiR 1 nuclear reactor. Neutron irradiation was simulated with a Monte Carlo radiation transport code MCNP. To compare dose–response, gel samples from the same production batch were also irradiated with 6 MV photons from a medical linear accelerator. Irradiated gel phantoms then underwent magnetic resonance imaging to determine their R2 relaxation rate maps. The measured and normalized dose distribution in the epithermal neutron beam was compared with the dose distribution calculated by computer simulation. The results support the feasibility of using MAGIC gel in BNCT dosimetry. PACS numbers: 87.53.Qc, 87.53.Wz, 87.66.Ff PMID:17592463

  10. INEL BNCT Research Program Annual Report 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Venhuizen, J.R.

    1994-08-01

    This report is a summary of the progress and research produced for the Idaho National Engineering Laboratory Boron Neutron Capture Therapy Research Program for calendar year 1993. Contributions from all the principal investigators are included, covering chemistry (pituitary tumor studies, boron drug development including liposomes, lipoproteins, and carboranylalanine derivatives), pharmacology (murine screenings, toxicity testing, boron drug analysis), physics (radiation dosimetry software, neutron beam and filter design, neutron beam measurement dosimetry), and radiation biology (tissue and efficacy studies of small and large animal models). Information on the potential toxicity of borocaptate sodium and boronophenylalanine is presented. Results of 21 spontaneous-tumor-bearing dogsmore » that have been treated with boron neutron capture therapy at the Brookhaven National Laboratory are updated. Boron-containing drug purity verification is discussed in some detail. Advances in magnetic resonance imaging of boron in vivo are discussed. Several boron-carrying drugs exhibiting good tumor uptake are described. Significant progress in the potential of treating pituitary tumors is presented. Measurement of the epithermal-neutron flux of the Petten (The Netherlands) High Flux Reactor beam (HFB11B), and comparison to predictions are shown.« less

  11. CZAEM USER'S GUIDE: MODELING CAPTURE ZONES OF GROUND-WATER WELLS USING ANALYTIC ELEMENTS

    EPA Science Inventory

    The computer program CZAEM is designed for elementary capture zone analysis, and is based on the analytic element method. CZAEM is applicable to confined and/or unconfined low in shallow aquifers; the Dupuit-Forchheimer assumption is adopted. CZAEM supports the following analyt...

  12. Identification of a putative protein profile associating with tamoxifen therapy resistance in breast cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Umar, Arzu; Kang, Hyuk; Timmermans, A. M.

    2009-06-01

    Tamoxifen-resistance is a major cause of death in patients with recurrent breast cancer. Current clinical factors can correctly predict therapy response in only half of the treated patients. Identification of proteins that associate with tamoxifen-resistance is a first step towards better response prediction and tailored treatment of patients. In the present study we intended to identify putative protein biomarkers indicative of tamoxifen therapy-resistance in breast cancer, using nanoLC coupled with FTICR MS. Comparative proteome analysis was performed on ~5,500 pooled tumor cells (corresponding to ~550 ng protein lysate/analysis) obtained through laser capture microdissection (LCM) from two independently processed data setsmore » (n=24 and n=27) containing both tamoxifen therapy-sensitive and therapy-resistant tumors. Peptides and proteins were identified by matching mass and elution time of newly acquired LC-MS features to information in previously generated accurate mass and time tag (AMT) reference databases.« less

  13. Boron neutron capture therapy induces cell cycle arrest and cell apoptosis of glioma stem/progenitor cells in vitro

    PubMed Central

    2013-01-01

    Background Glioma stem cells in the quiescent state are resistant to clinical radiation therapy. An almost inevitable glioma recurrence is due to the persistence of these cells. The high linear energy transfer associated with boron neutron capture therapy (BNCT) could kill quiescent and proliferative cells. Methods The present study aimed to evaluate the effects of BNCT on glioma stem/progenitor cells in vitro. The damage induced by BNCT was assessed using cell cycle progression, apoptotic cell ratio and apoptosis-associated proteins expression. Results The surviving fraction and cell viability of glioma stem/progenitor cells were decreased compared with differentiated glioma cells using the same boronophenylalanine pretreatment and the same dose of neutron flux. BNCT induced cell cycle arrest in the G2/M phase and cell apoptosis via the mitochondrial pathway, with changes in the expression of associated proteins. Conclusions Glioma stem/progenitor cells, which are resistant to current clinical radiotherapy, could be effectively killed by BNCT in vitro via cell cycle arrest and apoptosis using a prolonged neutron irradiation, although radiosensitivity of glioma stem/progenitor cells was decreased compared with differentiated glioma cells when using the same dose of thermal neutron exposure and boronophenylalanine pretreatment. Thus, BNCT could offer an appreciable therapeutic advantage to prevent tumor recurrence, and may become a promising treatment in recurrent glioma. PMID:23915425

  14. Third Conference on Artificial Intelligence for Space Applications, part 2

    NASA Technical Reports Server (NTRS)

    Denton, Judith S. (Compiler); Freeman, Michael S. (Compiler); Vereen, Mary (Compiler)

    1988-01-01

    Topics relative to the application of artificial intelligence to space operations are discussed. New technologies for space station automation, design data capture, computer vision, neural nets, automatic programming, and real time applications are discussed.

  15. Evaluation of ULV Applications Against Old World Sand Fly (Diptera: Psychodidae) Species in Equatorial Kenya

    DTIC Science & Technology

    2011-01-01

    patterns of UV-labeled droplets captured on cotton ribbons adjacent to sand ßy cages in spray plots did not match patterns ofmortality.Wediscuss the...untreated areas. Surprisingly, ULV active ingredient deposition inferred from patterns of UV-labeled droplets captured on cotton ribbons adjacent to...the west plot on the second spray day; looking south. Cotton droplet capture ribbons have already been attached in position between the posts at each

  16. Successful treatment of capture myopathy in three wild greater sandhill cranes (Grus canadensis tabida).

    PubMed

    Businga, Nancy K; Langenberg, Julie; Carlson, LaVinda

    2007-12-01

    Two adult and 1 juvenile free-flying greater sandhill cranes (Grus canadensis tabida) were diagnosed with capture myopathy after alpha-chloralose baiting and physical capture during a banding and feeding ecologic study. Blood samples were collected for serum biochemical analysis at the time of capture for the 2 adults, and at 24 hours postcapture, at various intervals during treatment, and at the time of release for all 3 birds. Concentrations of creatine kinase, aspartate transaminase, and lactate dehydrogenase were high within 1 hour of capture and peaked approximately 3 days after capture. By days 10-17 after capture, creatine kinase and lactate dehydrogenase concentrations both decreased to within the reference range measured for cranes at capture, but aspartate transaminase concentrations remained 2-5 times higher than the measured reference range. Treatment consisted of corticosteroids, selenium/vitamin E, parenteral fluids, and gavage feedings. Physical therapy consisted of assisting the cranes to stand and walk 2-8 times a day, massaging leg muscles, and moving limbs manually through the range of motion. The adults were released when they were able to stand up independently and were pacing in the pen. The juvenile was released 12 hours after it was able to stand independently but was returned to the pen when it fell and could not rise. It was treated supportively for an additional 3 days and then successfully released. Both adult cranes were observed on their territories with their original mates after release and returned to their territories for the subsequent 8 years, raising chicks most years. After release, the juvenile was observed in a flock of cranes near its natal territory for the next 2 days.

  17. Microfluidic device with integrated microfilter of conical-shaped holes for high efficiency and high purity capture of circulating tumor cells

    NASA Astrophysics Data System (ADS)

    Tang, Yadong; Shi, Jian; Li, Sisi; Wang, Li; Cayre, Yvon E.; Chen, Yong

    2014-08-01

    Capture of circulating tumor cells (CTCs) from peripheral blood of cancer patients has major implications for metastatic detection and therapy analyses. Here we demonstrated a microfluidic device for high efficiency and high purity capture of CTCs. The key novelty of this approach lies on the integration of a microfilter with conical-shaped holes and a micro-injector with cross-flow components for size dependent capture of tumor cells without significant retention of non-tumor cells. Under conditions of constant flow rate, tumor cells spiked into phosphate buffered saline could be recovered and then cultured for further analyses. When tumor cells were spiked in blood of healthy donors, they could also be recovered at high efficiency and high clearance efficiency of white blood cells. When the same device was used for clinical validation, CTCs could be detected in blood samples of cancer patients but not in that of healthy donors. Finally, the capture efficiency of tumor cells is cell-type dependent but the hole size of the filter should be more closely correlated to the nuclei size of the tumor cells. Together with the advantage of easy operation, low-cost and high potential of integration, this approach offers unprecedented opportunities for metastatic detection and cancer treatment monitoring.

  18. Model-Based Systems Engineering for Capturing Mission Architecture System Processes with an Application Case Study - Orion Flight Test 1

    NASA Technical Reports Server (NTRS)

    Bonanne, Kevin H.

    2011-01-01

    Model-based Systems Engineering (MBSE) is an emerging methodology that can be leveraged to enhance many system development processes. MBSE allows for the centralization of an architecture description that would otherwise be stored in various locations and formats, thus simplifying communication among the project stakeholders, inducing commonality in representation, and expediting report generation. This paper outlines the MBSE approach taken to capture the processes of two different, but related, architectures by employing the Systems Modeling Language (SysML) as a standard for architecture description and the modeling tool MagicDraw. The overarching goal of this study was to demonstrate the effectiveness of MBSE as a means of capturing and designing a mission systems architecture. The first portion of the project focused on capturing the necessary system engineering activities that occur when designing, developing, and deploying a mission systems architecture for a space mission. The second part applies activities from the first to an application problem - the system engineering of the Orion Flight Test 1 (OFT-1) End-to-End Information System (EEIS). By modeling the activities required to create a space mission architecture and then implementing those activities in an application problem, the utility of MBSE as an approach to systems engineering can be demonstrated.

  19. Application of the Statistical ICA Technique in the DANCE Data Analysis

    NASA Astrophysics Data System (ADS)

    Baramsai, Bayarbadrakh; Jandel, M.; Bredeweg, T. A.; Rusev, G.; Walker, C. L.; Couture, A.; Mosby, S.; Ullmann, J. L.; Dance Collaboration

    2015-10-01

    The Detector for Advanced Neutron Capture Experiments (DANCE) at the Los Alamos Neutron Science Center is used to improve our understanding of the neutron capture reaction. DANCE is a highly efficient 4 π γ-ray detector array consisting of 160 BaF2 crystals which make it an ideal tool for neutron capture experiments. The (n, γ) reaction Q-value equals to the sum energy of all γ-rays emitted in the de-excitation cascades from the excited capture state to the ground state. The total γ-ray energy is used to identify reactions on different isotopes as well as the background. However, it's challenging to identify contribution in the Esum spectra from different isotopes with the similar Q-values. Recently we have tested the applicability of modern statistical methods such as Independent Component Analysis (ICA) to identify and separate different (n, γ) reaction yields on different isotopes that are present in the target material. ICA is a recently developed computational tool for separating multidimensional data into statistically independent additive subcomponents. In this conference talk, we present some results of the application of ICA algorithms and its modification for the DANCE experimental data analysis. This research is supported by the U. S. Department of Energy, Office of Science, Nuclear Physics under the Early Career Award No. LANL20135009.

  20. Integration of image capture and processing: beyond single-chip digital camera

    NASA Astrophysics Data System (ADS)

    Lim, SukHwan; El Gamal, Abbas

    2001-05-01

    An important trend in the design of digital cameras is the integration of capture and processing onto a single CMOS chip. Although integrating the components of a digital camera system onto a single chip significantly reduces system size and power, it does not fully exploit the potential advantages of integration. We argue that a key advantage of integration is the ability to exploit the high speed imaging capability of CMOS image senor to enable new applications such as multiple capture for enhancing dynamic range and to improve the performance of existing applications such as optical flow estimation. Conventional digital cameras operate at low frame rates and it would be too costly, if not infeasible, to operate their chips at high frame rates. Integration solves this problem. The idea is to capture images at much higher frame rates than he standard frame rate, process the high frame rate data on chip, and output the video sequence and the application specific data at standard frame rate. This idea is applied to optical flow estimation, where significant performance improvements are demonstrate over methods using standard frame rate sequences. We then investigate the constraints on memory size and processing power that can be integrated with a CMOS image sensor in a 0.18 micrometers process and below. We show that enough memory and processing power can be integrated to be able to not only perform the functions of a conventional camera system but also to perform applications such as real time optical flow estimation.

  1. Continuous whole-system monitoring toward rapid understanding of production HPC applications and systems

    DOE PAGES

    Agelastos, Anthony; Allan, Benjamin; Brandt, Jim; ...

    2016-05-18

    A detailed understanding of HPC applications’ resource needs and their complex interactions with each other and HPC platform resources are critical to achieving scalability and performance. Such understanding has been difficult to achieve because typical application profiling tools do not capture the behaviors of codes under the potentially wide spectrum of actual production conditions and because typical monitoring tools do not capture system resource usage information with high enough fidelity to gain sufficient insight into application performance and demands. In this paper we present both system and application profiling results based on data obtained through synchronized system wide monitoring onmore » a production HPC cluster at Sandia National Laboratories (SNL). We demonstrate analytic and visualization techniques that we are using to characterize application and system resource usage under production conditions for better understanding of application resource needs. Furthermore, our goals are to improve application performance (through understanding application-to-resource mapping and system throughput) and to ensure that future system capabilities match their intended workloads.« less

  2. Symmetric and asymmetric halogen-containing metallocarboranylporphyrins and uses thereof

    DOEpatents

    Miura, Michiko; Wu, Haitao

    2013-05-21

    The present invention is directed to low toxicity boronated compounds and methods for their use in the treatment, visualization, and diagnosis of tumors. More specifically, the present invention is directed to low toxicity halogenated, carborane-containing 5,10,15,20-tetraphenylporphyrin compounds and methods for their use particularly in boron neutron capture therapy (BNCT) and photodynamic therapy (PDT) for the treatment of tumors of the brain, head and neck, and surrounding tissue. The invention is also directed to using these halogenated, carborane-containing tetraphenylporphyrin compounds in methods of tumor imaging and/or diagnosis such as MRI, SPECT, or PET.

  3. Rapid identification and susceptibility testing of uropathogenic microbes via immunosorbent ATP-bioluminescence assay on a microfluidic simulator for antibiotic therapy.

    PubMed

    Dong, Tao; Zhao, Xinyan

    2015-02-17

    The incorporation of pathogen identification with antimicrobial susceptibility testing (AST) was implemented on a concept microfluidic simulator, which is well suited for personalizing antibiotic treatment of urinary tract infections (UTIs). The microfluidic device employs a fiberglass membrane sandwiched between two polypropylene components, with capture antibodies immobilized on the membrane. The chambers in the microfluidic device share the same geometric distribution as the wells in a standard 384-well microplate, resulting in compatibility with common microplate readers. Thirteen types of common uropathogenic microbes were selected as the analytes in this study. The microbes can be specifically captured by various capture antibodies and then quantified via an ATP bioluminescence assay (ATP-BLA) either directly or after a variety of follow-up tests, including urine culture, antibiotic treatment, and personalized antibiotic therapy simulation. Owing to the design of the microfluidic device, as well as the antibody specificity and the ATP-BLA sensitivity, the simulator was proven to be able to identify UTI pathogen species in artificial urine samples within 20 min and to reliably and simultaneously verify the antiseptic effects of eight antibiotic drugs within 3-6 h. The measurement range of the device spreads from 1 × 10(3) to 1 × 10(5) cells/mL in urine samples. We envision that the medical simulator might be broadly employed in UTI treatment and could serve as a model for the diagnosis and treatment of other diseases.

  4. Hybrid Capture-Based Tumor Sequencing and Copy Number Analysis to Confirm Origin of Metachronous Metastases in BRCA1-Mutant Cholangiocarcinoma Harboring a Novel YWHAZ-BRAF Fusion.

    PubMed

    Lim, Huat C; Montesion, Meagan; Botton, Thomas; Collisson, Eric A; Umetsu, Sarah E; Behr, Spencer C; Gordan, John D; Stephens, Phil J; Kelley, Robin K

    2018-04-05

    Biliary tract cancers such as cholangiocarcinoma represent a heterogeneous group of cancers that can be difficult to diagnose. Recent comprehensive genomic analyses in large cholangiocarcinoma cohorts have defined important molecular subgroups within cholangiocarcinoma that may relate to anatomic location and etiology [1-4] and may predict responsiveness to targeted therapies in development [5-7]. These emerging data highlight the potential for tumor genomics to inform diagnosis and treatment options in this challenging tumor type. We report the case of a patient with a germline BRCA1 mutation who presented with a cholangiocarcinoma driven by the novel YWHAZ-BRAF fusion. Hybrid capture-based DNA sequencing and copy number analysis performed as part of clinical care demonstrated that two later-occurring tumors were clonally derived from the primary cholangiocarcinoma rather than distinct new primaries, revealing an unusual pattern of late metachronous metastasis. We discuss the clinical significance of these genetic alterations and their relevance to therapeutic strategies. Hybrid capture-based next-generation DNA sequencing assays can provide diagnostic clarity in patients with unusual patterns of metastasis and recurrence in which the pathologic diagnosis is ambiguous.To our knowledge, this is the first reported case of a YWHAZ-BRAF fusion in pancreaticobiliary cancer, and a very rare case of cholangiocarcinoma in the setting of a germline BRCA1 mutation.The patient's BRCA1 mutation and YWHAZ-BRAF fusion constitute potential targets for future therapy. © AlphaMed Press 2018.

  5. Radiobiological response of U251MG, CHO-K1 and V79 cell lines to accelerator-based boron neutron capture therapy

    PubMed Central

    Sato, Eisuke; Zaboronok, Alexander; Yamamoto, Tetsuya; Nakai, Kei; Taskaev, Sergey; Volkova, Olga; Mechetina, Ludmila; Taranin, Alexander; Kanygin, Vladimir; Isobe, Tomonori; Mathis, Bryan J; Matsumura, Akira

    2018-01-01

    Abstract In the current article, we provide in vitro efficacy evaluation of a unique accelerator-based neutron source, constructed at the Budker Institute of Nuclear Physics (Novosibirsk, Russian Federation), for boron neutron capture therapy (BNCT), which is particularly effective in the case of invasive cancers. U251MG, CHO-K1 and V79 cells were incubated and irradiated in various concentrations of boric acid with epithermal neutrons for 2–3 h in a plexiglass phantom, using 2.0 MeV proton energy and 1.5–3.0 mA proton current, resulting in a neutron fluence of 2.16 × 1012 cm−2. The survival curves of cells loaded with boron were normalized to those irradiated without boron (to exclude the influence of the fast neutron and gamma dose components) and fit to the linear–quadratic (LQ) model. Colony formation assays showed the following cell survival rates (means ± SDs): CHO-K1: 0.348 ± 0.069 (10 ppm), 0.058 ± 0.017 (20 ppm), 0.018 ± 0.005 (40 ppm); V79: 0.476 ± 0.160 (10 ppm), 0.346 ± 0.053 (20 ppm), 0.078 ± 0.015 (40 ppm); and U251MG: 0.311 ± 0.061 (10 ppm), 0.131 ± 0.022 (20 ppm), 0.020 ± 0.010 (40 ppm). The difference between treated cells and controls was significant in all cases (P < 0.01) and confirmed that the neutron source and irradiation regimen were sufficient for control over cell colony formation. We believe our study will serve as a model for ongoing in vitro experiments on neutron capture therapy to advance in this area for further development of accelerator-based BNCT into the clinical phase. PMID:29281044

  6. Validated Measures of Illness Perception and Behavior in People with Knee Pain and Knee Osteoarthritis: A Scoping Review.

    PubMed

    Hamilton, Clayon B; Wong, Ming-Kin; Gignac, Monique A M; Davis, Aileen M; Chesworth, Bert M

    2017-01-01

    To identify validated measures that capture illness perception and behavior and have been used to assess people who have knee pain/osteoarthritis. A scoping review was performed. Nine electronic databases were searched for records from inception through April 19, 2015. Search terms included illness perception, illness behavior, knee, pain, osteoarthritis, and their related terms. This review included English language publications of primary data on people with knee pain/osteoarthritis who were assessed with validated measures capturing any of 4 components of illness perception and behavior: monitor body, define and interpret symptoms, take remedial action, and utilize sources of help. Seventy-one publications included relevant measures. Two reviewers independently coded and analyzed each relevant measure within the 4 components. Sixteen measures were identified that capture components of illness perception and behavior in the target population. These measures were originally developed to capture constructs that include coping strategies/skills/styles, illness belief, illness perception, self-efficacy, and pain behavior. Coding results indicated that 5, 11, 12, and 5 of these measures included the monitor body, define and interpret symptoms, take remedial action, and utilize sources of help components, respectively. Several validated measures were interpreted as capturing some components, and only 1 measure was interpreted as capturing all of the components of illness perception and behavior in the target population. A measure that comprehensively captures illness perception and behavior could be valuable for informing and evaluating therapy for patients along a continuum of symptomatic knee osteoarthritis. © 2016 World Institute of Pain.

  7. Geological Sequestration of CO2 A Brief Overview and Potential for Application for Oklahoma

    EPA Science Inventory

    Geologic sequestration of CO2 is a component of C capture and storage (CCS), an emerging technology for reducing CO2 emissions to the atmosphere, and involves injection of captured CO2 into deep subsurface formations. Similar to the injection of hazardous wastes, before injection...

  8. Aerial-broadcast application of diphacinone bait for rodent control in Hawai`i: Efficacy and non-target species risk assessment

    USGS Publications Warehouse

    Foote, David; Spurr, Eric B.; Lindsey, Gerald D.; Forbes Perry, Charlotte

    2015-01-01

    Introduced rats (Rattus rattus, R. exulans, and R. norvegicus) have been implicated in the decline or extinction of numerous species of plants and animals in Hawai‘i. This study investigated the efficacy of aerial-broadcast application of Ramik® Green baits containing 50 ppm (0.005%) diphacinone in reducing rat and mouse populations and the risk to non-target species. The study was undertaken in paired 45.56-ha treatment and non-treatment plots in Hawai‘i Volcanoes National Park. All 21 radio-collared rats in the treatment plot died within nine days of bait application, whereas none of the 18 radio-collared rats in the non-treatment plot died. There was a 99% drop in both the rat capture rate and percentage of non-toxic census bait blocks gnawed by rats in the treatment plot relative to the non-treatment plot three weeks after bait application. The only rat captured in the treatment plot three weeks after bait application was not ear-tagged (i.e., it was not a recapture), whereas 44% of the 52 rats captured in the non-treatment plot were ear-tagged. Most of the bait had disappeared from the forest floor within about one month of application. No birds likely to have eaten bait were found dead, although residues of diphacinone were found in the livers of three species of introduced seed-eating/omnivorous birds captured alive after bait application. No predatory birds were found dead one month or three months after bait application. The remains of a Hawaiian hawk (Buteo solitarius) were found six months after bait application, but it was not possible to determine the cause of death. This study demonstrated the efficacy of aerially broadcast diphacinone bait for control of rats and mice in Hawaiian montane forests, and was part of the dataset submitted to the U.S. Environmental Protection Agency for the national registration of a diphacinone bait for the control of rat populations in conservation areas.

  9. An evaluation of the various aspects of the progress in clinical applications of laser driven ionizing radiation

    NASA Astrophysics Data System (ADS)

    Hideghéty, K.; Szabó, E. R.; Polanek, R.; Szabó, Z.; Ughy, B.; Brunner, S.; Tőkés, T.

    2017-03-01

    There has been a vast development of laser-driven particle acceleration (LDPA) using high power lasers. This has initiated by the radiation oncology community to use the dose distribution and biological advantages of proton/heavy ion therapy in cancer treatment with a much greater accessibility than currently possible with cyclotron/synchrotron acceleration. Up to now, preclinical experiments have only been performed at a few LDPA facilities; technical solutions for clinical LDPA have been theoretically developed but there is still a long way to go for the clinical introduction of LDPA. Therefore, to explore the further potential bio-medical advantages of LDPA has pronounced importance. The main characteristics of LDPA are the ultra-high beam intensity, the flexibility in beam size reduction and the potential particle and energy selection whilst conventional accelerators generate single particle, quasi mono-energetic beams. There is a growing number of studies on the potential advantages and applications of Energy Modulated X-ray Radiotherapy, Modulated Electron Radiotherapy and Very High Energy Electron (VHEE) delivery system. Furthermore, the ultra-high space and/or time resolution of super-intense beams are under intensive investigation at synchrotrons (microbeam radiation and very high dose rate (> 40 Gy/s) electron accelerator flash irradiation) with growing evidence of significant improvement of the therapeutic index. Boron Neutron Capture Therapy (BNCT) is an advanced cell targeted binary treatment modality. Because of the high linear energy transfer (LET) of the two particles (7Li and 4He) released by 10BNC reaction, all of the energy is deposited inside the tumour cells, killing them with high probability, while the neighbouring cells are not damaged. The limited availability of appropriate neutron sources, prevent the more extensive exploration of clinical benefit of BNCT. Another boron-based novel binary approach is the 11B-Proton Fusion, which result in the release of three high LET alpha particles. These promising, innovative approaches for cancer therapy present huge challenges for dose calculation, dosimetry and for investigation of the biological effects. The planned LDPA (photons, VHEE, protons, carbon ions) at ELI facilities has the unique property of ultra-high dose rate (> Gy/s-10), short pulses, and at ELI-ALPS high repetition rate, have the potential to develop and establish encouraging novel methods working towards compact hospital-based clinical applications.

  10. Under-reporting of road traffic mortality in developing countries: application of a capture-recapture statistical model to refine mortality estimates.

    PubMed

    Samuel, Jonathan C; Sankhulani, Edward; Qureshi, Javeria S; Baloyi, Paul; Thupi, Charles; Lee, Clara N; Miller, William C; Cairns, Bruce A; Charles, Anthony G

    2012-01-01

    Road traffic injuries are a major cause of preventable death in sub-Saharan Africa. Accurate epidemiologic data are scarce and under-reporting from primary data sources is common. Our objectives were to estimate the incidence of road traffic deaths in Malawi using capture-recapture statistical analysis and determine what future efforts will best improve upon this estimate. Our capture-recapture model combined primary data from both police and hospital-based registries over a one year period (July 2008 to June 2009). The mortality incidences from the primary data sources were 0.075 and 0.051 deaths/1000 person-years, respectively. Using capture-recapture analysis, the combined incidence of road traffic deaths ranged 0.192-0.209 deaths/1000 person-years. Additionally, police data were more likely to include victims who were male, drivers or pedestrians, and victims from incidents with greater than one vehicle involved. We concluded that capture-recapture analysis is a good tool to estimate the incidence of road traffic deaths, and that capture-recapture analysis overcomes limitations of incomplete data sources. The World Health Organization estimated incidence of road traffic deaths for Malawi utilizing a binomial regression model and survey data and found a similar estimate despite strikingly different methods, suggesting both approaches are valid. Further research should seek to improve capture-recapture data through utilization of more than two data sources and improving accuracy of matches by minimizing missing data, application of geographic information systems, and use of names and civil registration numbers if available.

  11. Under-Reporting of Road Traffic Mortality in Developing Countries: Application of a Capture-Recapture Statistical Model to Refine Mortality Estimates

    PubMed Central

    Samuel, Jonathan C.; Sankhulani, Edward; Qureshi, Javeria S.; Baloyi, Paul; Thupi, Charles; Lee, Clara N.; Miller, William C.; Cairns, Bruce A.; Charles, Anthony G.

    2012-01-01

    Road traffic injuries are a major cause of preventable death in sub-Saharan Africa. Accurate epidemiologic data are scarce and under-reporting from primary data sources is common. Our objectives were to estimate the incidence of road traffic deaths in Malawi using capture-recapture statistical analysis and determine what future efforts will best improve upon this estimate. Our capture-recapture model combined primary data from both police and hospital-based registries over a one year period (July 2008 to June 2009). The mortality incidences from the primary data sources were 0.075 and 0.051 deaths/1000 person-years, respectively. Using capture-recapture analysis, the combined incidence of road traffic deaths ranged 0.192–0.209 deaths/1000 person-years. Additionally, police data were more likely to include victims who were male, drivers or pedestrians, and victims from incidents with greater than one vehicle involved. We concluded that capture-recapture analysis is a good tool to estimate the incidence of road traffic deaths, and that capture-recapture analysis overcomes limitations of incomplete data sources. The World Health Organization estimated incidence of road traffic deaths for Malawi utilizing a binomial regression model and survey data and found a similar estimate despite strikingly different methods, suggesting both approaches are valid. Further research should seek to improve capture-recapture data through utilization of more than two data sources and improving accuracy of matches by minimizing missing data, application of geographic information systems, and use of names and civil registration numbers if available. PMID:22355338

  12. A Machine-Learning-Driven Sky Model.

    PubMed

    Satylmys, Pynar; Bashford-Rogers, Thomas; Chalmers, Alan; Debattista, Kurt

    2017-01-01

    Sky illumination is responsible for much of the lighting in a virtual environment. A machine-learning-based approach can compactly represent sky illumination from both existing analytic sky models and from captured environment maps. The proposed approach can approximate the captured lighting at a significantly reduced memory cost and enable smooth transitions of sky lighting to be created from a small set of environment maps captured at discrete times of day. The author's results demonstrate accuracy close to the ground truth for both analytical and capture-based methods. The approach has a low runtime overhead, so it can be used as a generic approach for both offline and real-time applications.

  13. Examples of the nonlinear dynamics of ballistic capture and escape in the earth-moon system

    NASA Technical Reports Server (NTRS)

    Belbruno, Edward A.

    1990-01-01

    An example of a trajectory is given which is initially captured in an elliptic resonant orbit about the earth and then ballistically escapes the earth-moon system. This is demonstrated by a numerical example in three-dimensions using a planetary ephemeris. Another example shows a mechanism of how an elliptic orbit about the earth can increase its energy by performing a complex nonlinear transition to an elliptic orbit of a larger semi-major axis. Capture is also considered. An application of ballistic capture at the moon via an unstable periodic orbit using the four-body sun-earth-moon-S/C interaction is described.

  14. Research on Capturing of Customer Requirements Based on Innovation Theory

    NASA Astrophysics Data System (ADS)

    junwu, Ding; dongtao, Yang; zhenqiang, Bao

    To exactly and effectively capture customer requirements information, a new customer requirements capturing modeling method was proposed. Based on the analysis of function requirement models of previous products and the application of technology system evolution laws of the Theory of Innovative Problem Solving (TRIZ), the customer requirements could be evolved from existing product designs, through modifying the functional requirement unit and confirming the direction of evolution design. Finally, a case study was provided to illustrate the feasibility of the proposed approach.

  15. A review of ion sources for medical accelerators (invited)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muramatsu, M.; Kitagawa, A.

    2012-02-15

    There are two major medical applications of ion accelerators. One is a production of short-lived isotopes for radionuclide imaging with positron emission tomography and single photon emission computer tomography. Generally, a combination of a source for negative ions (usually H- and/or D-) and a cyclotron is used; this system is well established and distributed over the world. Other important medical application is charged-particle radiotherapy, where the accelerated ion beam itself is being used for patient treatment. Two distinctly different methods are being applied: either with protons or with heavy-ions (mostly carbon ions). Proton radiotherapy for deep-seated tumors has become widespreadmore » since the 1990s. The energy and intensity are typically over 200 MeV and several 10{sup 10} pps, respectively. Cyclotrons as well as synchrotrons are utilized. The ion source for the cyclotron is generally similar to the type for production of radioisotopes. For a synchrotron, one applies a positive ion source in combination with an injector linac. Carbon ion radiotherapy awakens a worldwide interest. About 6000 cancer patients have already been treated with carbon beams from the Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences in Japan. These clinical results have clearly verified the advantages of carbon ions. Heidelberg Ion Therapy Center and Gunma University Heavy Ion Medical Center have been successfully launched. Several new facilities are under commissioning or construction. The beam energy is adjusted to the depth of tumors. It is usually between 140 and 430 MeV/u. Although the beam intensity depends on the irradiation method, it is typically several 10{sup 8} or 10{sup 9} pps. Synchrotrons are only utilized for carbon ion radiotherapy. An ECR ion source supplies multi-charged carbon ions for this requirement. Some other medical applications with ion beams attract developer's interests. For example, the several types of accelerators are under development for the boron neutron capture therapy. This treatment is conventionally demonstrated by a nuclear reactor, but it is strongly expected to replace the reactor by the accelerator. We report status of ion source for medical application and such scope for further developments.« less

  16. Design of photon converter and photoneutron target for High power electron accelerator based BNCT.

    PubMed

    Rahmani, Faezeh; Seifi, Samaneh; Anbaran, Hossein Tavakoli; Ghasemi, Farshad

    2015-12-01

    An electron accelerator, ILU-14, with current of 10 mA and 100 kW in power has been considered as one of the options for neutron source in Boron Neutron Capture Therapy (BNCT). The final design of neutron target has been obtained using MCNPX to optimize the neutron production. Tungsten in strip shape and D2O in cylindrical form have been proposed as the photon converter and the photoneutron target, respectively. In addition calculation of heat deposition in the photon target design has been considered to ensure mechanical stability of target. The results show that about 8.37×10(12) photoneutron/s with average energy of 615 keV can be produced by this neutron source design. In addition, using an appropriate beam shaping assembly an epithermal neutron flux of the order of 1.24×10(8) cm(-2) s(-1) can be obtained for BNCT applications. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Neutron measurement at the thermal column of the Malaysian Triga Mark II reactor using gold foil activation method and TLD

    NASA Astrophysics Data System (ADS)

    Shalbi, Safwan; Salleh, Wan Norhayati Wan; Mohamad Idris, Faridah; Aliff Ashraff Rosdi, Muhammad; Syahir Sarkawi, Muhammad; Liyana Jamsari, Nur; Nasir, Nur Aishah Mohd

    2018-01-01

    In order to design facilities for boron neutron capture therapy (BNCT), the neutron measurement must be considered to obtain the optimal design of BNCT facility such as collimator and shielding. The previous feasibility study showed that the thermal column could generate higher thermal neutrons yield for BNCT application at the TRIGA MARK II reactor. Currently, the facility for BNCT are planned to be developed at thermal column. Thus, the main objective was focused on the thermal neutron and epithermal neutron flux measurement at the thermal column. In this measurement, pure gold and cadmium were used as a filter to obtain the thermal and epithermal neutron fluxes from inside and outside of the thermal column door of the 200kW reactor power using a gold foil activation method. The results were compared with neutron fluxes using TLD 600 and TLD 700. The outcome of this work will become the benchmark for the design of BNCT collimator and the shielding

  18. Application of Pharmacokinetic and Pharmacodynamic Analysis to the Development of Liposomal Formulations for Oncology

    PubMed Central

    Ait-Oudhia, Sihem; Mager, Donald E.; Straubinger, Robert M.

    2014-01-01

    Liposomal formulations of anticancer agents have been developed to prolong drug circulating lifetime, enhance anti-tumor efficacy by increasing tumor drug deposition, and reduce drug toxicity by avoiding critical normal tissues. Despite the clinical approval of numerous liposome-based chemotherapeutics, challenges remain in the development and clinical deployment of micro- and nano-particulate formulations, as well as combining these novel agents with conventional drugs and standard-of-care therapies. Factors requiring optimization include control of drug biodistribution, release rates of the encapsulated drug, and uptake by target cells. Quantitative mathematical modeling of formulation performance can provide an important tool for understanding drug transport, uptake, and disposition processes, as well as their role in therapeutic outcomes. This review identifies several relevant pharmacokinetic/pharmacodynamic models that incorporate key physical, biochemical, and physiological processes involved in delivery of oncology drugs by liposomal formulations. They capture observed data, lend insight into factors determining overall antitumor response, and in some cases, predict conditions for optimizing chemotherapy combinations that include nanoparticulate drug carriers. PMID:24647104

  19. Developing an eBook-Integrated High-Fidelity Mobile App Prototype for Promoting Child Motor Skills and Taxonomically Assessing Children's Emotional Responses Using Face and Sound Topology.

    PubMed

    Brown, William; Liu, Connie; John, Rita Marie; Ford, Phoebe

    2014-01-01

    Developing gross and fine motor skills and expressing complex emotion is critical for child development. We introduce "StorySense", an eBook-integrated mobile app prototype that can sense face and sound topologies and identify movement and expression to promote children's motor skills and emotional developmental. Currently, most interactive eBooks on mobile devices only leverage "low-motor" interaction (i.e. tapping or swiping). Our app senses a greater breath of motion (e.g. clapping, snapping, and face tracking), and dynamically alters the storyline according to physical responses in ways that encourage the performance of predetermined motor skills ideal for a child's gross and fine motor development. In addition, our app can capture changes in facial topology, which can later be mapped using the Facial Action Coding System (FACS) for later interpretation of emotion. StorySense expands the human computer interaction vocabulary for mobile devices. Potential clinical applications include child development, physical therapy, and autism.

  20. In vitro pharmacokinetic/pharmacodynamic models in anti-infective drug development: focus on TB

    PubMed Central

    Vaddady, Pavan K; Lee, Richard E; Meibohm, Bernd

    2011-01-01

    For rapid anti-tuberculosis (TB) drug development in vitro pharmacokinetic/pharmacodynamic (PK/PD) models are useful in evaluating the direct interaction between the drug and the bacteria, thereby guiding the selection of candidate compounds and the optimization of their dosing regimens. Utilizing in vivo drug-clearance profiles from animal and/or human studies and simulating them in an in vitro PK/PD model allows the in-depth characterization of antibiotic activity of new and existing antibacterials by generating time–kill data. These data capture the dynamic interplay between mycobacterial growth and changing drug concentration as encountered during prolonged drug therapy. This review focuses on important PK/PD parameters relevant to anti-TB drug development, provides an overview of in vitro PK/PD models used to evaluate the efficacy of agents against mycobacteria and discusses the related mathematical modeling approaches of time–kill data. Overall, it provides an introduction to in vitro PK/PD models and their application as critical tools in evaluating anti-TB drugs. PMID:21359155

  1. Layer-by-layer assemblies for cancer treatment and diagnosis

    PubMed Central

    Liu, Xi Qiu; Picart, Catherine

    2016-01-01

    The layer-by-layer (LbL) technique was introduced in the early 90s by Profs Moehwald, Lvov and Decher. Since then, it has undergone a series of technological developments, making it possible to engineer various theranostic platforms such as films and capsules, with precise control at the nanometer and micrometer scales. This Research News article highlights recent progress in the applications of LbL assemblies in the field of cancer therapy, diagnosis and fundamental biology study. The potentials of LbL-based systems as drug carriers are discussed, especially with regard to the engineering of innovative stimuli-responsive systems, and their advantageous multifunctionality in the development of new therapeutic tools. Then, the diagnostic functions of LbL assemblies are illustrated for detection and capture of rare cancer cells. Finally, LbL mimicking extracellular environments demonstrate the emerging potential for the study of cancer cell behaviors in vitro. We conclude by highlighting the advantages of LbL systems, important challenges that need to be overcome, and future perspectives in clinical practice. PMID:26390356

  2. A hybrid fuzzy-ontology based intelligent system to determine level of severity and treatment recommendation for Benign Prostatic Hyperplasia.

    PubMed

    Torshizi, Abolfazl Doostparast; Zarandi, Mohammad Hossein Fazel; Torshizi, Ghazaleh Doostparast; Eghbali, Kamyar

    2014-01-01

    This paper deals with application of fuzzy intelligent systems in diagnosing severity level and recommending appropriate therapies for patients having Benign Prostatic Hyperplasia. Such an intelligent system can have remarkable impacts on correct diagnosis of the disease and reducing risk of mortality. This system captures various factors from the patients using two modules. The first module determines severity level of the Benign Prostatic Hyperplasia and the second module, which is a decision making unit, obtains output of the first module accompanied by some external knowledge and makes an appropriate treatment decision based on its ontology model and a fuzzy type-1 system. In order to validate efficiency and accuracy of the developed system, a case study is conducted by 44 participants. Then the results are compared with the recommendations of a panel of experts on the experimental data. Then precision and accuracy of the results were investigated based on a statistical analysis. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  3. Synthesis of water dispersible boron core silica shell (B@SiO2) nanoparticles

    NASA Astrophysics Data System (ADS)

    Walton, Nathan I.; Gao, Zhe; Eygeris, Yulia; Ghandehari, Hamidreza; Zharov, Ilya

    2018-04-01

    Water dispersible boron nanoparticles have great potential as materials for boron neutron capture therapy of cancer and magnetic resonance imaging, if they are prepared on a large scale with uniform size and shape and hydrophilic modifiable surface. We report the first method to prepare spherical, monodisperse, water dispersible boron core silica shell nanoparticles (B@SiO2 NPs) suitable for aforementioned biomedical applications. In this method, 40 nm elemental boron nanoparticles, easily prepared by mechanical milling and carrying 10-undecenoic acid surface ligands, are hydrosilylated using triethoxysilane, followed by base-catalyzed hydrolysis of tetraethoxysilane, which forms a 10-nm silica shell around the boron core. This simple two-step process converts irregularly shaped hydrophobic boron particles into the spherically shaped uniform nanoparticles. The B@SiO2 NPs are dispersible in water and the silica shell surface can be modified with primary amines that allow for the attachment of a fluorophore and, potentially, of targeting moieties. [Figure not available: see fulltext.

  4. Multifaceted Applications of Chitosan in Cancer Drug Delivery and Therapy.

    PubMed

    Babu, Anish; Ramesh, Rajagopal

    2017-03-27

    Chitosan is a versatile polysaccharide of biological origin. Due to the biocompatible and biodegradable nature of chitosan, it is intensively utilized in biomedical applications in scaffold engineering as an absorption enhancer, and for bioactive and controlled drug release. In cancer therapy, chitosan has multifaceted applications, such as assisting in gene delivery and chemotherapeutic delivery, and as an immunoadjuvant for vaccines. The present review highlights the recent applications of chitosan and chitosan derivatives in cancer therapy.

  5. Multifaceted Applications of Chitosan in Cancer Drug Delivery and Therapy

    PubMed Central

    Babu, Anish; Ramesh, Rajagopal

    2017-01-01

    Chitosan is a versatile polysaccharide of biological origin. Due to the biocompatible and biodegradable nature of chitosan, it is intensively utilized in biomedical applications in scaffold engineering as an absorption enhancer, and for bioactive and controlled drug release. In cancer therapy, chitosan has multifaceted applications, such as assisting in gene delivery and chemotherapeutic delivery, and as an immunoadjuvant for vaccines. The present review highlights the recent applications of chitosan and chitosan derivatives in cancer therapy. PMID:28346381

  6. Study on data acquisition system based on reconfigurable cache technology

    NASA Astrophysics Data System (ADS)

    Zhang, Qinchuan; Li, Min; Jiang, Jun

    2018-03-01

    Waveform capture rate is one of the key features of digital acquisition systems, which represents the waveform processing capability of the system in a unit time. The higher the waveform capture rate is, the larger the chance to capture elusive events is and the more reliable the test result is. First, this paper analyzes the impact of several factors on the waveform capture rate of the system, then the novel technology based on reconfigurable cache is further proposed to optimize system architecture, and the simulation results show that the signal-to-noise ratio of signal, capacity, and structure of cache have significant effects on the waveform capture rate. Finally, the technology is demonstrated by the engineering practice, and the results show that the waveform capture rate of the system is improved substantially without significant increase of system's cost, and the technology proposed has a broad application prospect.

  7. Quantitative evaluation of boron neutron capture therapy (BNCT) drugs for boron delivery and retention at subcellular scale resolution in human glioblastoma cells with imaging secondary ion mass spectrometry (SIMS)

    PubMed Central

    Chandra, S.; Ahmad, T.; Barth, R. F.; Kabalka, G. W.

    2014-01-01

    Boron neutron capture therapy (BNCT) of cancer depends on the selective delivery of a sufficient number of boron-10 (10B) atoms to individual tumor cells. Cell killing results from the 10B (n, α)7Li neutron capture and fission reactions that occur if a sufficient number of 10B atoms are localized in the tumor cells. Intranuclear 10B localization enhances the efficiency of cell killing via damage to the DNA. The net cellular content of 10B atoms reflects both bound and free pools of boron in individual tumor cells. The assessment of these pools, delivered by a boron delivery agent, currently cannot be made at subcellular scale resolution by clinically applicable techniques such as PET and MRI. In this study, secondary ion mass spectrometry (SIMS) based imaging instrument, a CAMECA IMS 3f ion microscope, capable of 500 nm spatial resolution was employed. Cryogenically prepared cultured human T98G glioblastoma cells were evaluated for boron uptake and retention of two delivery agents. The first, L-p-boronophenylalanine (BPA), has been used clinically for BNCT of high grade gliomas, recurrent tumors of the head and neck region and melanomas. The second, a boron analogue of an unnatural amino acid, 1-amino-3-borono-cyclopentanecarboxylic acid (cis-ABCPC), has been studied in rodent glioma and melanoma models by quantification of boron in the nucleus and cytoplasm of individual tumor cells. The bound and free pools of boron were assessed by exposure of cells to boron-free nutrient medium. Both BPA and cis-ABCPC delivered almost 70% of the pool of boron in the free or loosely bound form to the nucleus and cytoplasm of human glioblastoma cells. This free pool of boron could be easily mobilized out of the cell and was in some sort of equilibrium with extracellular boron. In the case of BPA, the intracellular free pool of boron also was affected by the presence of phenylalanine in the nutrient medium. This suggests that it might be advantageous if patients were placed on a low phenylalanine diet prior to the initiation of BNCT. Since BPA currently is used clinically for BNCT, our observations may have direct relevance to future clinical studies utilizing this agent and provides support for individualized treatment planning regimens rather than the use of fixed BPA infusion protocols. PMID:24684609

  8. Quantitative evaluation of boron neutron capture therapy (BNCT) drugs for boron delivery and retention at subcellular-scale resolution in human glioblastoma cells with imaging secondary ion mass spectrometry (SIMS).

    PubMed

    Chandra, S; Ahmad, T; Barth, R F; Kabalka, G W

    2014-06-01

    Boron neutron capture therapy (BNCT) of cancer depends on the selective delivery of a sufficient number of boron-10 ((10)B) atoms to individual tumour cells. Cell killing results from the (10)B (n, α)(7) Li neutron capture and fission reactions that occur if a sufficient number of (10)B atoms are localized in the tumour cells. Intranuclear (10)B localization enhances the efficiency of cell killing via damage to the DNA. The net cellular content of (10)B atoms reflects both bound and free pools of boron in individual tumour cells. The assessment of these pools, delivered by a boron delivery agent, currently cannot be made at subcellular-scale resolution by clinically applicable techniques such as positron emission tomography and magnetic resonance imaging. In this study, a secondary ion mass spectrometry based imaging instrument, a CAMECA IMS 3f ion microscope, capable of 500 nm spatial resolution was employed. Cryogenically prepared cultured human T98G glioblastoma cells were evaluated for boron uptake and retention of two delivery agents. The first, L-p-boronophenylalanine (BPA), has been used clinically for BNCT of high-grade gliomas, recurrent tumours of the head and neck region and melanomas. The second, a boron analogue of an unnatural amino acid, 1-amino-3-borono-cyclopentanecarboxylic acid (cis-ABCPC), has been studied in rodent glioma and melanoma models by quantification of boron in the nucleus and cytoplasm of individual tumour cells. The bound and free pools of boron were assessed by exposure of cells to boron-free nutrient medium. Both BPA and cis-ABCPC delivered almost 70% of the pool of boron in the free or loosely bound form to the nucleus and cytoplasm of human glioblastoma cells. This free pool of boron could be easily mobilized out of the cell and was in some sort of equilibrium with extracellular boron. In the case of BPA, the intracellular free pool of boron also was affected by the presence of phenylalanine in the nutrient medium. This suggests that it might be advantageous if patients were placed on a low phenylalanine diet prior to the initiation of BNCT. Since BPA currently is used clinically for BNCT, our observations may have direct relevance to future clinical studies utilizing this agent and provides support for individualized treatment planning regimens rather than the use of fixed BPA infusion protocols. © 2014 The Authors Journal of Microscopy © 2014 Royal Microscopical Society.

  9. In the palm of your hand.

    PubMed

    Monteverdi, B

    2001-01-01

    The explosive growth of handheld personal digital assistants (PDAs) in health care has been nothing short of amazing. What applications--business and clinical--do these devices have in medicine, and what is their potential? PDAs are simple and intuitive; their applications require minimal interaction time, so they have minimal impact on work flow: the investment is small; and the lightweight form is relatively nonintrusive during a patient encounter. The devices are being used to capture charges for medical services at the point of care. Encounter capture, online prescription writing and other applications will soon come on the scene. This article discusses current and possible future uses for PDAs in health care, interfaces with other technologies and security concerns.

  10. High-throughput screening of metal-porphyrin-like graphenes for selective capture of carbon dioxide

    PubMed Central

    Bae, Hyeonhu; Park, Minwoo; Jang, Byungryul; Kang, Yura; Park, Jinwoo; Lee, Hosik; Chung, Haegeun; Chung, ChiHye; Hong, Suklyun; Kwon, Yongkyung; Yakobson, Boris I.; Lee, Hoonkyung

    2016-01-01

    Nanostructured materials, such as zeolites and metal-organic frameworks, have been considered to capture CO2. However, their application has been limited largely because they exhibit poor selectivity for flue gases and low capture capacity under low pressures. We perform a high-throughput screening for selective CO2 capture from flue gases by using first principles thermodynamics. We find that elements with empty d orbitals selectively attract CO2 from gaseous mixtures under low CO2 pressures (~10−3 bar) at 300 K and release it at ~450 K. CO2 binding to elements involves hybridization of the metal d orbitals with the CO2 π orbitals and CO2-transition metal complexes were observed in experiments. This result allows us to perform high-throughput screening to discover novel promising CO2 capture materials with empty d orbitals (e.g., Sc– or V–porphyrin-like graphene) and predict their capture performance under various conditions. Moreover, these findings provide physical insights into selective CO2 capture and open a new path to explore CO2 capture materials. PMID:26902156

  11. High-throughput screening of metal-porphyrin-like graphenes for selective capture of carbon dioxide.

    PubMed

    Bae, Hyeonhu; Park, Minwoo; Jang, Byungryul; Kang, Yura; Park, Jinwoo; Lee, Hosik; Chung, Haegeun; Chung, ChiHye; Hong, Suklyun; Kwon, Yongkyung; Yakobson, Boris I; Lee, Hoonkyung

    2016-02-23

    Nanostructured materials, such as zeolites and metal-organic frameworks, have been considered to capture CO2. However, their application has been limited largely because they exhibit poor selectivity for flue gases and low capture capacity under low pressures. We perform a high-throughput screening for selective CO2 capture from flue gases by using first principles thermodynamics. We find that elements with empty d orbitals selectively attract CO2 from gaseous mixtures under low CO2 pressures (~10(-3) bar) at 300 K and release it at ~450 K. CO2 binding to elements involves hybridization of the metal d orbitals with the CO2 π orbitals and CO2-transition metal complexes were observed in experiments. This result allows us to perform high-throughput screening to discover novel promising CO2 capture materials with empty d orbitals (e.g., Sc- or V-porphyrin-like graphene) and predict their capture performance under various conditions. Moreover, these findings provide physical insights into selective CO2 capture and open a new path to explore CO2 capture materials.

  12. High-throughput screening of metal-porphyrin-like graphenes for selective capture of carbon dioxide

    NASA Astrophysics Data System (ADS)

    Bae, Hyeonhu; Park, Minwoo; Jang, Byungryul; Kang, Yura; Park, Jinwoo; Lee, Hosik; Chung, Haegeun; Chung, Chihye; Hong, Suklyun; Kwon, Yongkyung; Yakobson, Boris I.; Lee, Hoonkyung

    2016-02-01

    Nanostructured materials, such as zeolites and metal-organic frameworks, have been considered to capture CO2. However, their application has been limited largely because they exhibit poor selectivity for flue gases and low capture capacity under low pressures. We perform a high-throughput screening for selective CO2 capture from flue gases by using first principles thermodynamics. We find that elements with empty d orbitals selectively attract CO2 from gaseous mixtures under low CO2 pressures (~10-3 bar) at 300 K and release it at ~450 K. CO2 binding to elements involves hybridization of the metal d orbitals with the CO2 π orbitals and CO2-transition metal complexes were observed in experiments. This result allows us to perform high-throughput screening to discover novel promising CO2 capture materials with empty d orbitals (e.g., Sc- or V-porphyrin-like graphene) and predict their capture performance under various conditions. Moreover, these findings provide physical insights into selective CO2 capture and open a new path to explore CO2 capture materials.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agelastos, Anthony; Allan, Benjamin; Brandt, Jim

    A detailed understanding of HPC applications’ resource needs and their complex interactions with each other and HPC platform resources are critical to achieving scalability and performance. Such understanding has been difficult to achieve because typical application profiling tools do not capture the behaviors of codes under the potentially wide spectrum of actual production conditions and because typical monitoring tools do not capture system resource usage information with high enough fidelity to gain sufficient insight into application performance and demands. In this paper we present both system and application profiling results based on data obtained through synchronized system wide monitoring onmore » a production HPC cluster at Sandia National Laboratories (SNL). We demonstrate analytic and visualization techniques that we are using to characterize application and system resource usage under production conditions for better understanding of application resource needs. Furthermore, our goals are to improve application performance (through understanding application-to-resource mapping and system throughput) and to ensure that future system capabilities match their intended workloads.« less

  14. Multiple-predators-based capture process on complex networks

    NASA Astrophysics Data System (ADS)

    Ramiz Sharafat, Rajput; Pu, Cunlai; Li, Jie; Chen, Rongbin; Xu, Zhongqi

    2017-03-01

    The predator/prey (capture) problem is a prototype of many network-related applications. We study the capture process on complex networks by considering multiple predators from multiple sources. In our model, some lions start from multiple sources simultaneously to capture the lamb by biased random walks, which are controlled with a free parameter $\\alpha$. We derive the distribution of the lamb's lifetime and the expected lifetime $\\left\\langle T\\right\\rangle $. Through simulation, we find that the expected lifetime drops substantially with the increasing number of lions. We also study how the underlying topological structure affects the capture process, and obtain that locating on small-degree nodes is better than large-degree nodes to prolong the lifetime of the lamb. Moreover, dense or homogeneous network structures are against the survival of the lamb.

  15. INEL BNCT Program: Volume 5, No. 9. Bulletin, September 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ackermann, A.L.

    1991-12-31

    This Bulletin presents a summary of accomplishments and highlights of the Idaho National Engineering Laboratory`s (INEL) Boron Neutron Capture Therapy (BNCT) Program for September 1991. This bulletin includes information on the brain tumor and melanoma research programs, Power Burst Facility (PBF) technical support and modifications, PBF operations, and updates to the animal data charts.

  16. Farm Tractors, Occupational Therapy, and Four-Wheel Drive: Transforming a Military Vehicle into a Cultural Icon

    ERIC Educational Resources Information Center

    Iarocci, Andrew

    2010-01-01

    The armed forces of World War II employed unprecedented numbers of mechanical transport vehicles, precipitating a spike in demand for automotive manufactures. Eager to capture a share of the less certain postwar automobile marketplace, defense contractors such as Willys-Overland pursued a diverse range of product development and advertising…

  17. Alemtuzumab: validation of a sensitive and simple enzyme-linked immunosorbent assay.

    PubMed

    Jilani, Iman; Keating, Michael; Giles, Francis J; O'Brien, Susan; Kantarjian, Hagop M; Albitar, Maher

    2004-12-01

    Alemtuzumab (MabCampath) is a humanized rat monoclonal antibody that targets the CD52 antigen. It has been approved for the treatment of patients with resistant chronic lymphocytic leukaemia (CLL). Measuring plasma/serum levels of alemtuzumab is important for optimizing the dosing and scheduling of therapy; however, current assays in serum or plasma, based on the capture of alemtuzumab using CD52, are complicated and difficult to adapt for high throughput testing. We developed a simple sandwich enzyme-linked immunosorbent assay (ELISA) to measure alemtuzumab that takes advantage of the remaining rat sequence in alemtuzumab. Using specific anti-rat immunoglobulin (Ig) antibodies (absorbed against human Ig), alemtuzumab levels were measured in the serum and plasma of patients treated with alemtuzumab. Levels were similar between plasma and serum samples, in fresh samples and samples stored at 4 degrees C for 24 h, but were significantly lower in samples stored at room temperature for 24h. The assay was successfully used to determine serum alemtuzumab pre- and post-treatment. This assay is simple and adaptable for high throughput testing, with a limit of detection of 0.05 microg/ml and a coefficient of variation of +/-12.5%. No false positivity was observed in >200 samples tested. This validated assay should help optimize the dosing and scheduling of alemtuzumab therapy. The underlying principles are also applicable to the measurement of other humanized antibodies using an appropriate anti-Ig.

  18. Freeze the Moment: High Speed Capturing of Weakly Bonded Dynamic Nanoparticle Assemblies in Solution by Ag Ion Soldering.

    PubMed

    Wang, Yueliang; Fang, Lingling; Chen, Gaoli; Song, Lei; Deng, Zhaoxiang

    2018-02-01

    Despite the versatile forms of colloidal aggregates, these spontaneously formed structures are often hard to find a suitable application in nanotechnology and materials science. A determinate reason is the lack of a suitable method to capture the transiently formed and quickly evolving colloidal structures in solution. To address this challenge, a simple but highly efficient strategy is herein reported to capture the dynamic and metastable colloidal assemblies formed in an aqueous or nonaqueous solution. This process takes advantage of a recently developed Ag ion soldering reaction to realize a rapid fixation of as-formed metastable assemblies. This method works efficiently for both solid (3D) nanoparticle aggregates and weakly bonded fractal nanoparticle chains (1D). In both cases, very high capturing speed and close to 100% efficiency are achieved to fully retain a quickly growing structure. The soldered nanochains further enable a fabrication of discrete, uniform, and functionalizable nanoparticle clusters with enriched linear conformation by mechanical shearing, which would otherwise be difficult to make. The captured products are water dispersible and mechanically robust, favoring an exploration of their properties toward possible applications. The work paves a way to previously untouched aspects of colloidal science and thus would create new chances in nanotechnology. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Albumin-coated monodisperse magnetic poly(glycidyl methacrylate) microspheres with immobilized antibodies: application to the capture of epithelial cancer cells.

    PubMed

    Horák, Daniel; Svobodová, Zuzana; Autebert, Julien; Coudert, Benoit; Plichta, Zdeněk; Královec, Karel; Bílková, Zuzana; Viovy, Jean-Louis

    2013-01-01

    Monodisperse (4 μm) macroporous crosslinked poly(glycidyl methacrylate) (PGMA) microspheres for use in microfluidic immunomagnetic cell sorting, with a specific application to the capture of circulating tumor cells (CTCs), were prepared by multistep swelling polymerization in the presence of cyclohexyl acetate porogen and hydrolyzed and ammonolyzed. Iron oxide was then precipitated in the microspheres to render them magnetic. Repeated precipitation made possible to raise the iron oxide content to more than 30 wt %. To minimize nonspecific adsorption of the microspheres in a microchannel and of cells on the microspheres, they were coated with albumin crosslinked with glutaraldehyde. Antibodies of epithelial cell adhesion molecule (anti-EpCAM) were then immobilized on the albumin-coated magnetic microspheres using the carbodiimide method. Capture of breast cancer MCF7 cells as a model of CTCs by the microspheres with immobilized anti-EpCAM IgG was performed in a batch experiment. Finally, MCF7 cells were captured by the anti-EpCAM-immobilized albumin-coated magnetic microspheres in an Ephesia chip. A very good rejection of lymphocytes was achieved. Thus, albumin-coated monodisperse magnetic PGMA microspheres with immobilized anti-EpCAM seem to be promising for capture of CTCs in a microfluidic device. Copyright © 2012 Wiley Periodicals, Inc.

  20. NCI support for particle therapy: past, present, future.

    PubMed

    Deye, James A

    2012-11-01

    In light of the rising worldwide interest in particle therapy, and proton therapy specifically in the United States, the National Cancer Institute (NCI) is being asked more often about funding for such research and facilities. Many of the questions imply that NCI is naive to the exciting possibilities inherent in particle therapies, and thus they wish to encourage NCI to initiate and underwrite such programs. In fact, NCI has a long track record of support for the translation of hadrons from the physics laboratory to the therapy clinic by way of technology development and scientific investigations of physical and biological processes as well as clinical outcomes. Early work has included continuous funding since 1961 of proton treatments for more than 15,000 patients and facility construction at the Harvard/Massachusetts General Hospital (MGH) site; treatment of 227 patients with the pi-meson facility at Los Alamos between 1974 and 1981; funding of more than $69M for seven neutron therapy centers between 1971 and 1989; many funded projects in boron neutron capture radiation therapy through the present time; and numerous radiobiology projects over the past 50 y. NCI continues to play an active role in the incorporation of protons into randomized clinical trials through the Children's Oncology Group, Radiation Therapy Oncology Group, and the Program Project Grant (P01), which is co-directed by the MGH and MD Anderson Cancer Center. This has required funding development and implementation of guidelines that enable intercomparison of dosimetry and treatment between facilities. NCI has also funded recent efforts to develop new physical processes for the production of particles such as protons. With regard to the future, while it is true that there are no specific funding opportunity announcements directed to particle therapy research, it is also true that NCI remains open to reviewing any research that is compatible with an established mechanism. However, given the very substantial resources that these facilities currently require along with the highly competitive economic environment that now exists, it is clear that scientific review of such grant applications will look to leverage the scientific pursuits that are the NCI mandate with the reality of the clinical practices, just as is the case for photon radiation research. Such leveraging should be enhanced by the growing opportunities and need for international collaborations. On the other hand, these collaborations are complicated by the fact that these particle therapies are now fully reimbursable modalities, which makes it difficult to separate research (the NCI mission) from clinical practice development. This paper seeks to illuminate these new realities in order to encourage the pursuit and funding of the scientific underpinnings of physical methods, radiobiology, and clinical practice with particle therapy.

  1. WE-D-BRB-04: Clinical Applications of CBCT for Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teo, B.

    The goal of this session is to review the physics of proton therapy, treatment planning techniques, and the use of volumetric imaging in proton therapy. The course material covers the physics of proton interaction with matter and physical characteristics of clinical proton beams. It will provide information on proton delivery systems and beam delivery techniques for double scattering (DS), uniform scanning (US), and pencil beam scanning (PBS). The session covers the treatment planning strategies used in DS, US, and PBS for various anatomical sites, methods to address uncertainties in proton therapy and uncertainty mitigation to generate robust treatment plans. Itmore » introduces the audience to the current status of image guided proton therapy and clinical applications of CBCT for proton therapy. It outlines the importance of volumetric imaging in proton therapy. Learning Objectives: Gain knowledge in proton therapy physics, and treatment planning for proton therapy including intensity modulated proton therapy. The current state of volumetric image guidance equipment in proton therapy. Clinical applications of CBCT and its advantage over orthogonal imaging for proton therapy. B. Teo, B.K Teo had received travel funds from IBA in 2015.« less

  2. Thermoresponsive release of viable microfiltrated Circulating Tumor Cells (CTCs) for precision medicine applications

    PubMed Central

    Ao, Zheng; Parasido, Erika; Rawal, Siddarth; Williams, Anthony; Schlegel, Richard; Liu, Stephen; Albanese, Chris; Cote, Richard J.; Agarwal, Ashutosh; Datar, Ram H.

    2015-01-01

    Stimulus responsive release of Circulating Tumor Cells (CTCs), with high recovery rates from their capture platform, is highly desirable for off-chip analyses. Here, we present a temperature responsive polymer coating method to achieve both release as well as culture of viable CTCs captured from patient blood samples. PMID:26426331

  3. Bayesian Estimation of Random Coefficient Dynamic Factor Models

    ERIC Educational Resources Information Center

    Song, Hairong; Ferrer, Emilio

    2012-01-01

    Dynamic factor models (DFMs) have typically been applied to multivariate time series data collected from a single unit of study, such as a single individual or dyad. The goal of DFMs application is to capture dynamics of multivariate systems. When multiple units are available, however, DFMs are not suited to capture variations in dynamics across…

  4. Synthesis of amino-rich silica coated magnetic nanoparticles and their application in the capture of DNA for PCR

    USDA-ARS?s Scientific Manuscript database

    Magnetic separation has great advantages over traditional bioseparation methods and has become popular in the development of methods for the detection of bacterial pathogens, viruses, and transgenic crops. Functionalization of magnetic nanoparticles is a key factor in allowing efficient capture of t...

  5. Exploring Emotion in the Higher Education Workplace: Capturing Contrasting Perspectives Using Q Methodology

    ERIC Educational Resources Information Center

    Woods, Charlotte

    2012-01-01

    This article presents an original application of Q methodology in investigating the challenging arena of emotion in the Higher Education (HE) workplace. Q's strength lies in capturing holistic, subjective accounts of complex and contested phenomena but is unusual in employing a statistical procedure within an interpretivist framework. Here Q is…

  6. Electron Beam Analysis of Micrometeoroids Captured in Aerogel as Stardust Analogues

    NASA Technical Reports Server (NTRS)

    Graham, G. A.; Sheffield-Parker, J.; Bradley, P.; Kearsley, A. T.; Dai, Z. R.; Mayo, S. C.; Teslich, N.; Snead, C.; Westphal, A. J.; Ishii, H.

    2005-01-01

    In January 2004, NASA s Stardust spacecraft passed through the tail of Comet 81P/Wild-2. The on-board dust flux monitor instrument indicated that numerous micro- and nano-meter sized cometary dust particles were captured by the dedicated silica aerogel capture cell. The collected cometary particles will be returned to Earth in January 2006. Current Stardust analogues are: (i) Light-gas-gun accelerated individual mineral grains and carbonaceous meteoritic material in aerogels at the Stardust encounter velocity ca.approximately 6 kilometers per second. (ii) Aerogels exposed in low-Earth orbit (LEO) containing preserved cosmic dust grains. Studies of these impacts offer insight into the potential state of the captured cometary dust by Stardust and the suitability of various analytical techniques. A number of papers have discussed the application of sophisticated synchrotron analytical techniques to analyze Stardust particles. Yet much of the understanding gained on the composition and mineralogy of interplanetary dust particles (IDPs) has come from electron microscopy studies. Here we discuss the application of scanning electron microscopy (SEM) for Stardust during the preliminary phase of post-return investigations.

  7. Accuracy of human motion capture systems for sport applications; state-of-the-art review.

    PubMed

    van der Kruk, Eline; Reijne, Marco M

    2018-05-09

    Sport research often requires human motion capture of an athlete. It can, however, be labour-intensive and difficult to select the right system, while manufacturers report on specifications which are determined in set-ups that largely differ from sport research in terms of volume, environment and motion. The aim of this review is to assist researchers in the selection of a suitable motion capture system for their experimental set-up for sport applications. An open online platform is initiated, to support (sport)researchers in the selection of a system and to enable them to contribute and update the overview. systematic review; Method: Electronic searches in Scopus, Web of Science and Google Scholar were performed, and the reference lists of the screened articles were scrutinised to determine human motion capture systems used in academically published studies on sport analysis. An overview of 17 human motion capture systems is provided, reporting the general specifications given by the manufacturer (weight and size of the sensors, maximum capture volume, environmental feasibilities), and calibration specifications as determined in peer-reviewed studies. The accuracy of each system is plotted against the measurement range. The overview and chart can assist researchers in the selection of a suitable measurement system. To increase the robustness of the database and to keep up with technological developments, we encourage researchers to perform an accuracy test prior to their experiment and to add to the chart and the system overview (online, open access).

  8. Laser Capture Microdissection for Protein and NanoString RNA analysis

    PubMed Central

    Golubeva, Yelena; Salcedo, Rosalba; Mueller, Claudius; Liotta, Lance A.; Espina, Virginia

    2013-01-01

    Laser capture microdissection (LCM) allows the precise procurement of enriched cell populations from a heterogeneous tissue, or live cell culture, under direct microscopic visualization. Histologically enriched cell populations can be procured by harvesting cells of interest directly, or isolating specific cells by ablating unwanted cells. The basic components of laser microdissection technology are a) visualization of cells via light microscopy, b) transfer of laser energy to a thermolabile polymer with either the formation of a polymer-cell composite (capture method) or transfer of laser energy via an ultraviolet laser to photovolatize a region of tissue (cutting method), and c) removal of cells of interest from the heterogeneous tissue section. The capture and cutting methods (instruments) for laser microdissection differ in the manner by which cells of interest are removed from the heterogeneous sample. Laser energy in the capture method is infrared (810nm), while in the cutting mode the laser is ultraviolet (355nm). Infrared lasers melt a thermolabile polymer that adheres to the cells of interest, whereas ultraviolet lasers ablate cells for either removal of unwanted cells or excision of a defined area of cells. LCM technology is applicable to an array of applications including mass spectrometry, DNA genotyping and loss-of-heterozygosity analysis, RNA transcript profiling, cDNA library generation, proteomics discovery, and signal kinase pathway profiling. This chapter describes laser capture microdissection using an ArcturusXT instrument for protein LCM sample analysis, and using a mmi CellCut Plus® instrument for RNA analysis via NanoString technology. PMID:23027006

  9. Our solution for fusion of simultaneusly acquired whole body scintigrams and optical images, as usesful tool in clinical practice in patients with differentiated thyroid carcinomas after radioiodine therapy. A useful tool in clinical practice.

    PubMed

    Matovic, Milovan; Jankovic, Milica; Barjaktarovic, Marko; Jeremic, Marija

    2017-01-01

    After radioiodine therapy of differentiated thyroid cancer (DTC) patients, whole body scintigraphy (WBS) is standard procedure before releasing the patient from the hospital. A common problem is the precise localization of regions where the iod-avide tissue is located. Sometimes is practically impossible to perform precise topographic localization of such regions. In order to face this problem, we have developed a low-cost Vision-Fusion system for web-camera image acquisition simultaneously with routine scintigraphic whole body acquisition including the algorithm for fusion of images given from both cameras. For image acquisition in the gamma part of the spectra we used e.cam dual head gamma camera (Siemens, Erlangen, Germany) in WBS modality, with matrix size of 256×1024 pixels and bed speed of 6cm/min, equipped with high energy collimator. For optical image acquisition in visible part of spectra we have used web-camera model C905 (Logitech, USA) with Carl Zeiss® optics, native resolution 1600×1200 pixels, 34 o field of view, 30g weight, with autofocus option turned "off" and auto white balance turned "on". Web camera is connected to upper head of gamma camera (GC) by a holder of lightweight aluminum rod and a plexiglas adapter. Our own Vision-Fusion software for image acquisition and coregistration was developed using NI LabVIEW programming environment 2015 (National Instruments, Texas, USA) and two additional LabVIEW modules: NI Vision Acquisition Software (VAS) and NI Vision Development Module (VDM). Vision acquisition software enables communication and control between laptop computer and web-camera. Vision development module is image processing library used for image preprocessing and fusion. Software starts the web-camera image acquisition before starting image acquisition on GC and stops it when GC completes the acquisition. Web-camera is in continuous acquisition mode with frame rate f depending on speed of patient bed movement v (f=v/∆ cm , where ∆ cm is a displacement step that can be changed in Settings option of Vision-Fusion software; by default, ∆ cm is set to 1cm corresponding to ∆ p =15 pixels). All images captured while patient's bed is moving are processed. Movement of patient's bed is checked using cross-correlation of two successive images. After each image capturing, algorithm extracts the central region of interest (ROI) of the image, with the same width as captured image (1600 pixels) and the height that is equal to the ∆ p displacement in pixels. All extracted central ROI are placed next to each other in the overall whole-body image. Stacking of narrow central ROI introduces negligible distortion in the overall whole-body image. The first step for fusion of the scintigram and the optical image was determination of spatial transformation between them. We have made an experiment with two markers (point radioactivity sources of 99m Tc pertechnetate 1MBq) visible in both images (WBS and optical) to find transformation of coordinates between images. The distance between point markers is used for spatial coregistration of the gamma and optical images. At the end of coregistration process, gamma image is rescaled in spatial domain and added to the optical image (green or red channel, amplification changeable from user interface). We tested our system for 10 patients with DTC who received radioiodine therapy (8 women and two men, with average age of 50.10±12.26 years). Five patients received 5.55Gbq, three 3.70GBq and two 1.85GBq. Whole-body scintigraphy and optical image acquisition were performed 72 hours after application of radioiodine therapy. Based on our first results during clinical testing of our system, we can conclude that our system can improve diagnostic possibility of whole body scintigraphy to detect thyroid remnant tissue in patients with DTC after radioiodine therapy.

  10. Compact, Lightweight Adsorber and Sabatier Reactor for CO2 Capture and Reduction for Consumable and Propellant Production

    NASA Technical Reports Server (NTRS)

    Junaedi, Christian; Hawley, Kyle; Walsh, Dennis; Roychoudhury, Subir; Busby, Stacy A.; Abney, Morgan B.; Perry, Jay L.; Knox, James C.

    2012-01-01

    The utilization of CO2 to produce (or recycle) life support consumables, such as O2 and H2O, and to generate propellant fuels is an important aspect of NASA's concept for future, long duration planetary exploration. One potential approach is to capture and use CO2 from the Martian atmosphere to generate the consumables and propellant fuels. Precision Combustion, Inc. (PCI), with support from NASA, continues to develop its regenerable adsorber technology for capturing CO2 from gaseous atmospheres (for cabin atmosphere revitalization and in-situ resource utilization applications) and its Sabatier reactor for converting CO2 to methane and water. Both technologies are based on PCI's Microlith(R) substrates and have been demonstrated to reduce size, weight, and power consumption during CO2 capture and methanation process. For adsorber applications, the Microlith substrates offer a unique resistive heating capability that shows potential for short regeneration time and reduced power requirements compared to conventional systems. For the Sabatier applications, the combination of the Microlith substrates and durable catalyst coating permits efficient CO2 methanation that favors high reactant conversion, high selectivity, and durability. Results from performance testing at various operating conditions will be presented. An effort to optimize the Sabatier reactor and to develop a bench-top Sabatier Development Unit (SDU) will be discussed.

  11. Mind-body interventions: applications in neurology.

    PubMed

    Wahbeh, Helané; Elsas, Siegward-M; Oken, Barry S

    2008-06-10

    Half of the adults in the United States use complementary and alternative medicine with mind-body therapy being the most commonly used form. Neurology patients often turn to their physicians for insight into the effectiveness of the therapies and resources to integrate them into their care. The objective of this article is to give a clinical overview of mind-body interventions and their applications in neurology. Medline and PsychInfo were searched on mind-body therapies and neurologic disease search terms for clinical trials and reviews and published evidence was graded. Meditation, relaxation, and breathing techniques, yoga, tai chi, and qigong, hypnosis, and biofeedback are described. Mind-body therapy application to general pain, back and neck pain, carpal tunnel syndrome, headaches, fibromyalgia, multiple sclerosis, epilepsy, muscular dysfunction, stroke, aging, Parkinson disease, stroke, and attention deficit-hyperactivity disorder are reviewed. There are several conditions where the evidence for mind-body therapies is quite strong such as migraine headache. Mind-body therapies for other neurology applications have limited evidence due mostly to small clinical trials and inadequate control groups.

  12. Smartphone Spectrometers

    PubMed Central

    Willmott, Jon R.; Mims, Forrest M.; Parisi, Alfio V.

    2018-01-01

    Smartphones are playing an increasing role in the sciences, owing to the ubiquitous proliferation of these devices, their relatively low cost, increasing processing power and their suitability for integrated data acquisition and processing in a ‘lab in a phone’ capacity. There is furthermore the potential to deploy these units as nodes within Internet of Things architectures, enabling massive networked data capture. Hitherto, considerable attention has been focused on imaging applications of these devices. However, within just the last few years, another possibility has emerged: to use smartphones as a means of capturing spectra, mostly by coupling various classes of fore-optics to these units with data capture achieved using the smartphone camera. These highly novel approaches have the potential to become widely adopted across a broad range of scientific e.g., biomedical, chemical and agricultural application areas. In this review, we detail the exciting recent development of smartphone spectrometer hardware, in addition to covering applications to which these units have been deployed, hitherto. The paper also points forward to the potentially highly influential impacts that such units could have on the sciences in the coming decades. PMID:29342899

  13. Computerized image analysis for acetic acid induced intraepithelial lesions

    NASA Astrophysics Data System (ADS)

    Li, Wenjing; Ferris, Daron G.; Lieberman, Rich W.

    2008-03-01

    Cervical Intraepithelial Neoplasia (CIN) exhibits certain morphologic features that can be identified during a visual inspection exam. Immature and dysphasic cervical squamous epithelium turns white after application of acetic acid during the exam. The whitening process occurs visually over several minutes and subjectively discriminates between dysphasic and normal tissue. Digital imaging technologies allow us to assist the physician analyzing the acetic acid induced lesions (acetowhite region) in a fully automatic way. This paper reports a study designed to measure multiple parameters of the acetowhitening process from two images captured with a digital colposcope. One image is captured before the acetic acid application, and the other is captured after the acetic acid application. The spatial change of the acetowhitening is extracted using color and texture information in the post acetic acid image; the temporal change is extracted from the intensity and color changes between the post acetic acid and pre acetic acid images with an automatic alignment. The imaging and data analysis system has been evaluated with a total of 99 human subjects and demonstrate its potential to screening underserved women where access to skilled colposcopists is limited.

  14. The influence of capture-recapture methodology on the evolution of the North American Bird Banding Program

    USGS Publications Warehouse

    Tautin, J.; Lebreton, J.-D.; North, P.M.

    1993-01-01

    Capture-recapture methodology has advanced greatly in the last twenty years and is now a major factor driving the continuing evolution of the North American bird banding program. Bird banding studies are becoming more scientific with improved study designs and analytical procedures. Researchers and managers are gaining more reliable knowledge which in turn betters the conservation of migratory birds. The advances in capture-recapture methodology have benefited gamebird studies primarily, but nongame bird studies will benefit similarly as they expand greatly in the next decade. Further theoretical development of capture-recapture methodology should be encouraged, and, to maximize benefits of the methodology, work on practical applications should be increased.

  15. Enhanced protein retention on poly(caprolactone) via surface initiated polymerization of acrylamide

    NASA Astrophysics Data System (ADS)

    Ma, Yuhao; Cai, Mengtan; He, Liu; Luo, Xianglin

    2016-01-01

    To enhance the biocompatibility or extend the biomedical application of poly(caprolactone) (PCL), protein retention on PCL surface is often required. In this study, poly(acrylamide) (PAAm) brushes were grown from PCL surface via surface-initiated atom transfer radical polymerization (SI-ATRP) and served as a protein-capturing platform. Grafted PAAm was densely packed on surface and exhibited superior protein retention ability. Captured protein was found to be resistant to washing under detergent environment. Furthermore, protein structure after being captured was investigated by circular dichroism (CD) spectroscopy, and the CD spectra verified that secondary structure of captured proteins was maintained, indicating no denaturation of protein happened for retention process.

  16. Free stream capturing in fluid conservation law for moving coordinates in three dimensions

    NASA Technical Reports Server (NTRS)

    Obayashi, Shigeru

    1991-01-01

    The free-stream capturing technique for both the finite-volume (FV) and finite-difference (FD) framework is summarized. For an arbitrary motion of the grid, the FV analysis shows that volumes swept by all six surfaces of the cell have to be computed correctly. This means that the free-stream capturing time-metric terms should be calculated not only from a surface vector of a cell at a single time level, but also from a volume swept by the cell surface in space and time. The FV free-stream capturing formulation is applicable to the FD formulation by proper translation from an FV cell to an FD mesh.

  17. Enhancement of tumor responsiveness to aminolevulinate-photodynamic therapy (ALA-PDT) using differentiation-promoting agents in mouse models of skin carcinoma

    NASA Astrophysics Data System (ADS)

    Anand, Sanjay; Honari, Golara; Paliwal, Akshat; Hasan, Tayyaba; Maytin, Edward V.

    2009-06-01

    Aminolevulinic acid-mediated photodynamic therapy (ALA-PDT) is an emerging treatment for cancers. ALA, given as a prodrug, selectively accumulates and is metabolized in cancer cells to form protoporphyrin IX (PpIX). Targeted local irradiation with light induces cell death. Since the efficacy of ALA-PDT for large or deep tumors is currently limited, we are developing a new approach that combines differentiation-inducing agents with ALA-PDT to improve the clinical response. Here, we tested this new combination paradigm in the following two models of skin carcinoma in mice: 1) tumors generated by topical application of chemical carcinogens (DMBA-TPA); 2) human SCC cells (A431) implanted subcutaneously. To achieve a differentiated state of the tumors, pretreatment with a low concentration of methotrexate (MTX) or Vitamin D (Vit D) was administered for 72 h prior to exposure to ALA. Confocal images of histological sections were captured and digitally analyzed to determine relative PpIX levels. PpIX in the tumors was also monitored by real-time in vivo fluorescence dosimetry. In both models, a significant increase in levels of PpIX was observed following pretreatment with MTX or Vit D, as compared to no-pretreatment controls. This enhancing effect was observed at very low, non-cytotoxic concentrations, and was highly specific to cancer cells as compared to normal cells. These results suggest that use of differentiating agents such as MTX or Vit D, as a short-term combination therapy given prior to ALA-PDT, can increase the production of PpIX photosensitizer and enhance the therapeutic response of skin cancers.

  18. A method to assess social sustainability of capture fisheries: An application to a Norwegian trawler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veldhuizen, L.J.L., E-mail: linda.veldhuizen@wur.nl; Berentsen, P.B.M.; Bokkers, E.A.M.

    Social sustainability assessment of capture fisheries is, both in terms of method development and measurement, not well developed. The objective of this study, therefore, was to develop a method consisting of indicators and rubrics (i.e. categories that articulate levels of performance) to assess social sustainability of capture fisheries. This method was applied to a Norwegian trawler that targets cod and haddock in the northeast Atlantic. Based on previous research, 13 social sustainability issues were selected. To measure the state of these issues, 17 process and outcome indicators were determined. To interpret indicator values, rubrics were developed for each indicator, usingmore » standards set by international conventions or data retrieved from national statistics, industry agreements or scientific publications that explore rubric scales. The indicators and rubrics were subsequently used in a social sustainability assessment of a Norwegian trawler. This assessment indicated that overall, social sustainability of this trawler is relatively high, with high rubric scores, for example, for worker safety, provisions aboard for the crew and companies' salary levels. The assessment also indicated that the trawler could improve on healthy working environment, product freshness and fish welfare during capture. This application demonstrated that our method provides insight into social sustainability at the level of the vessel and can be used to identify potential room for improvement. This method is also promising for social sustainability assessment of other capture fisheries. - Highlights: • A method was developed for social sustainability assessment of capture fisheries. • This method entailed determining outcome and process indicators for important issues. • To interpret indicator values, a rubric was developed for each indicator. • Use of this method gives insight into social sustainability and improvement options. • This method is promising for social sustainability assessment of capture fisheries.« less

  19. Transit safety retrofit package development : applications requirements document.

    DOT National Transportation Integrated Search

    2014-05-01

    This Application Requirements Document for the Transit Safety Retrofit Package (TRP) Development captures the system, hardware and software requirements towards fulfilling the technical objectives stated within the contract. To achieve the objective ...

  20. High-throughput identification of antigen-specific TCRs by TCR gene capture.

    PubMed

    Linnemann, Carsten; Heemskerk, Bianca; Kvistborg, Pia; Kluin, Roelof J C; Bolotin, Dmitriy A; Chen, Xiaojing; Bresser, Kaspar; Nieuwland, Marja; Schotte, Remko; Michels, Samira; Gomez-Eerland, Raquel; Jahn, Lorenz; Hombrink, Pleun; Legrand, Nicolas; Shu, Chengyi Jenny; Mamedov, Ilgar Z; Velds, Arno; Blank, Christian U; Haanen, John B A G; Turchaninova, Maria A; Kerkhoven, Ron M; Spits, Hergen; Hadrup, Sine Reker; Heemskerk, Mirjam H M; Blankenstein, Thomas; Chudakov, Dmitriy M; Bendle, Gavin M; Schumacher, Ton N M

    2013-11-01

    The transfer of T cell receptor (TCR) genes into patient T cells is a promising approach for the treatment of both viral infections and cancer. Although efficient methods exist to identify antibodies for the treatment of these diseases, comparable strategies to identify TCRs have been lacking. We have developed a high-throughput DNA-based strategy to identify TCR sequences by the capture and sequencing of genomic DNA fragments encoding the TCR genes. We establish the value of this approach by assembling a large library of cancer germline tumor antigen-reactive TCRs. Furthermore, by exploiting the quantitative nature of TCR gene capture, we show the feasibility of identifying antigen-specific TCRs in oligoclonal T cell populations from either human material or TCR-humanized mice. Finally, we demonstrate the ability to identify tumor-reactive TCRs within intratumoral T cell subsets without knowledge of antigen specificities, which may be the first step toward the development of autologous TCR gene therapy to target patient-specific neoantigens in human cancer.

  1. Hadron Therapy in Latin America

    NASA Astrophysics Data System (ADS)

    Kreiner, A. J.; Bergueiro, J.; Burlon, A. A.; Di Paolo, H.; Castell, W.; Thatar Vento, V.; Levinas, P.; Cartelli, D.; Kesque, J. M.; Valda, A. A.; Ilardo, J. C.; Baldo, M.; Erhardt, J.; Debray, M. E.; Somacal, H. R.; Minsky, D. M.; Estrada, L.; Hazarabedian, A.; Johann, F.; Suarez Sandin, J. C.; Igarzabal, M.; Huck, H.; Repetto, M.; Obligado, M.; Lell, J.; Padulo, J.; Herrera, M.; Gonzalez, S. R.; Capoulat, M. E.; Davidson, J.; Davidson, M.

    2010-08-01

    The use of proton and heavy ion beams for radiotherapy is a well established cancer treatment modality in the first world, which is becoming increasingly widespread, due to its clear advantages over conventional photon-based treatments. This strategy is suitable when the tumor is spatially well localized. Also the use of neutrons has tradition. Here Boron Neutron Capture Therapy (BNCT) stands out, though on a much smaller scale, being a promising alternative for tumors which are diffuse and infiltrating. On this sector, so far only nuclear reactors have been used as neutron sources. In this paper we briefly describe the situation in Latin America and in particular we discuss the present status of an ongoing project to develop a folded Tandem-ElectroStatic-Quadrupole (TESQ) accelerator for Accelerator-Based (AB)-Boron Neutron Capture Therapy (BNCT) at the Atomic Energy Commission of Argentina. The project goal is a machine capable of delivering 30 mA of 2.4 MeV protons to be used in conjunction with a neutron production target based on the 7Li(p,n)7Be reaction. These are the specifications needed to produce sufficiently intense and clean epithermal neutron beams to perform BNCT for deep-seated tumors in less than an hour. The machine being currently designed and constructed is a folded TESQ with a terminal at 0.6 MV as a smaller scale prototype. Since the concept is modular the same structure will be used for the 1.2 MV final accelerator.

  2. Maximizing profitability in a hospital outpatient pharmacy.

    PubMed

    Jorgenson, J A; Kilarski, J W; Malatestinic, W N; Rudy, T A

    1989-07-01

    This paper describes the strategies employed to increase the profitability of an existing ambulatory pharmacy operated by the hospital. Methods to generate new revenue including implementation of a home parenteral therapy program, a home enteral therapy program, a durable medical equipment service, and home care disposable sales are described. Programs to maximize existing revenue sources such as increasing the capture rate on discharge prescriptions, increasing "walk-in" prescription traffic and increasing HMO prescription volumes are discussed. A method utilized to reduce drug expenditures is also presented. By minimizing expenses and increasing the revenues for the ambulatory pharmacy operation, net profit increased from +26,000 to over +140,000 in one year.

  3. Coronary Sinus Lead Positioning.

    PubMed

    Roka, Attila; Borgquist, Rasmus; Singh, Jagmeet

    2015-12-01

    Although cardiac resynchronization therapy improves morbidity and mortality in patients with cardiomyopathy, heart failure, and electrical dyssynchrony, the rate of nonresponders using standard indications and implant techniques is still high. Optimal coronary sinus lead positioning is important to increase the chance of successful resynchronization. Patient factors such as cause of heart failure, type of dyssynchrony, scar burden, coronary sinus anatomy, and phrenic nerve capture may affect the efficacy of the therapy. Several modalities are under investigation. Alternative left ventricular lead implantation strategies are occasionally required when the transvenous route is not feasible or would result in a suboptimal lead position. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Coronary Sinus Lead Positioning.

    PubMed

    Roka, Attila; Borgquist, Rasmus; Singh, Jagmeet

    2017-01-01

    Although cardiac resynchronization therapy improves morbidity and mortality in patients with cardiomyopathy, heart failure, and electrical dyssynchrony, the rate of nonresponders using standard indications and implant techniques is still high. Optimal coronary sinus lead positioning is important to increase the chance of successful resynchronization. Patient factors such as cause of heart failure, type of dyssynchrony, scar burden, coronary sinus anatomy, and phrenic nerve capture may affect the efficacy of the therapy. Several modalities are under investigation. Alternative left ventricular lead implantation strategies are occasionally required when the transvenous route is not feasible or would result in a suboptimal lead position. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Feasibility of a novel one-stop ISET device to capture CTCs and its clinical application

    PubMed Central

    Zheng, Liang; Zhi, Xuan; Cheng, Boran; Chen, Yuanyuan; Zhang, Chunxiao; Shi, Dongdong; Song, Haibin; Cai, Congli; Zhou, Pengfei; Xiong, Bin

    2017-01-01

    Introduction Circulating tumor cells (CTCs) play a crucial role in cancer metastasis. In this study, we introduced a novel isolation method by size of epithelial tumor cells (ISET) device with automatic isolation and staining procedure, named one-stop ISET (osISET) and validated its feasibility to capture CTCs from cancer patients. Moreover, we aim to investigate the correlation between clinicopathologic features and CTCs in colorectal cancer (CRC) in order to explore its clinical application. Results The capture efficiency ranged from 80.3% to 88% with tumor cells spiked into medium while 67% to 78.3% with tumor cells spiked into healthy donors’ blood. In detection blood samples of 72 CRC patients, CTCs and clusters of circulating tumor cells (CTC-clusters) were detected with a positive rate of 52.8% (38/72) and 18.1% (13/72) respectively. Moreover, CTC positive rate was associated with factors of lymphatic or venous invasion, tumor depth, lymph node metastasis and TNM stage in CRC patients (p < 0.01). Lymphocyte count and neutrophil to lymphocyte ratio (NLR) were significantly different between CTC positive and negative groups (p < 0.01). Materials and Methods The capture efficiency of the device was tested by spiking cancer cells (MCF-7, A549, SW480, Hela) into medium or blood samples of healthy donors. Blood samples of 72 CRC patients were detected by osISET device. The clinicopathologic characteristics of 72 CRC patients were collected and the association with CTC positive rate or CTC count were analyzed. Conclusions Our osISET device was feasible to capture and identify CTCs and CTC-clusters from cancer patients. In addition, our device holds a potential for application in cancer management. PMID:27935872

  6. Data Provenance Hybridization Supporting Extreme-Scale Scientific WorkflowApplications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elsethagen, Todd O.; Stephan, Eric G.; Raju, Bibi

    As high performance computing (HPC) infrastructures continue to grow in capability and complexity, so do the applications that they serve. HPC and distributed-area computing (DAC) (e.g. grid and cloud) users are looking increasingly toward workflow solutions to orchestrate their complex application coupling, pre- and post-processing needs To gain insight and a more quantitative understanding of a workflow’s performance our method includes not only the capture of traditional provenance information, but also the capture and integration of system environment metrics helping to give context and explanation for a workflow’s execution. In this paper, we describe IPPD’s provenance management solution (ProvEn) andmore » its hybrid data store combining both of these data provenance perspectives.« less

  7. General features of the dissociative recombination of polyatomic molecules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pratt, S. T.; Jungen, Ch.; Schneider, I. F.

    We discuss some aspects of a simple expression for the low-energy dissociative recombination cross section that applies when the recombination process is dominated by the indirect mechanism. In most previous applications, this expression has been applied to capture into vibrationally excited Rydberg states with the assumption that capture is always followed by prompt dissociation. Here we consider the dissociative recombination of larger polyatomic ions and electrons. More specifically, we consider capture into electronically core-excited Rydberg states, and begin to assess its potential importance for larger systems.

  8. General features of the dissociative recombination of polyatomic molecules

    DOE PAGES

    Pratt, S. T.; Jungen, Ch.; Schneider, I. F.; ...

    2015-01-29

    We discuss some aspects of a simple expression for the low-energy dissociative recombination cross section that applies when the recombination process is dominated by the indirect mechanism. In most previous applications, this expression has been applied to capture into vibrationally excited Rydberg states with the assumption that capture is always followed by prompt dissociation. Here we consider the dissociative recombination of larger polyatomic ions and electrons. More specifically, we consider capture into electronically core-excited Rydberg states, and begin to assess its potential importance for larger systems.

  9. Application of Polynomial Neural Networks to Classification of Acoustic Warfare Signals

    DTIC Science & Technology

    1993-04-01

    on Neural Networks, Vol. II, Jun’e, 1987. [66] Shynk, J.J., "Adaptive IIR filtering," IEEE ASSP Magazine, Vol. 6, No. 2, Apr. 1989. 175 I [67] Specht ...rows This is the size of the yellow capture window which will be displayed on the screen. The best setting for pixel-rows is two greater than exemplar...exemplar size of 4 to be captured by the PNN. The pixel-rows setting is 6, which allows all four rows of I the retina data to fit inside yellow capture

  10. Managing the potential and pitfalls during clinical translation of emerging stem cell therapies

    PubMed Central

    2014-01-01

    We are moving into a new era of stem cell research where many possibilities for treatment of degenerative, chronic and/or fatal diseases and injuries are becoming primed for clinical trial. These reports have led millions of people worldwide to hope that regenerative medicine is about to revolutionise biomedicine: either through transplantation of cells grown in the laboratory, or by finding ways to stimulate a patient’s intrinsic stem cells to repair diseased and damaged organs. While major contributions of stem cells to drug discovery, safety and efficacy testing, as well as modelling ‘diseases in a dish’ are also expected, it is the in vivo use of stem cells that has captured the general public’s attention. However, public misconceptions of stem cell potential and applications can leave patients vulnerable to the influences of profit driven entities selling unproven treatments without solid scientific basis or appropriate clinical testing or follow up. This review provides a brief history of stem cell clinical translation together with an overview of the properties, potential, and current clinical application of various stem cell types. In doing so it presents a clearer picture of the inherent risks and opportunities associated with stem cell research translation, and thus offers a framework to help realise invested expectations more quickly, safely and effectively. PMID:24949190

  11. Laboratory Directed Research and Development Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ogeka, G.J.; Romano, A.J.

    This report briefly discusses the following research: Advances in Geoexploration; Transvenous Coronary Angiography with Synchrotron X-Rays; Borehole Measurements of Global Warming; Molecular Ecology: Development of Field Methods for Microbial Growth Rate and Activity Measurements; A New Malaria Enzyme - A Potential Source for a New Diagnostic Test for Malaria and a Target for a New Antimalarial Drug; Basic Studies on Thoron and Thoron Precursors; Cloning of the cDNA for a Human Serine/Threonine Protein Kinase that is Activated Specifically by Double-Stranded DNA; Development of an Ultra-Fast Laser System for Accelerator Applications; Cluster Impact Fusion; Effect of a Bacterial Spore Protein onmore » Mutagenesis; Structure and Function of Adenovirus Penton Base Protein; High Resolution Fast X-Ray Detector; Coherent Synchrotron Radiation Longitudinal Bunch Shape Monitor; High Grain Harmonic Generation Experiment; BNL Maglev Studies; Structural Investigations of Pt-Based Catalysts; Studies on the Cellular Toxicity of Cocaine and Cocaethylene; Human Melanocyte Transformation; Exploratory Applications of X-Ray Microscopy; Determination of the Higher Ordered Structure of Eukaryotic Chromosomes; Uranium Neutron Capture Therapy; Tunneling Microscopy Studies of Nanoscale Structures; Nuclear Techiques for Study of Biological Channels; RF Sources for Accelerator Physics; Induction and Repair of Double-Strand Breaks in the DNA of Human Lymphocytes; and An EBIS Source of High Charge State Ions up to Uranium.« less

  12. Laboratory Directed Research and Development Program. Annual report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ogeka, G.J.; Romano, A.J.

    This report briefly discusses the following research: Advances in Geoexploration; Transvenous Coronary Angiography with Synchrotron X-Rays; Borehole Measurements of Global Warming; Molecular Ecology: Development of Field Methods for Microbial Growth Rate and Activity Measurements; A New Malaria Enzyme - A Potential Source for a New Diagnostic Test for Malaria and a Target for a New Antimalarial Drug; Basic Studies on Thoron and Thoron Precursors; Cloning of the cDNA for a Human Serine/Threonine Protein Kinase that is Activated Specifically by Double-Stranded DNA; Development of an Ultra-Fast Laser System for Accelerator Applications; Cluster Impact Fusion; Effect of a Bacterial Spore Protein onmore » Mutagenesis; Structure and Function of Adenovirus Penton Base Protein; High Resolution Fast X-Ray Detector; Coherent Synchrotron Radiation Longitudinal Bunch Shape Monitor; High Grain Harmonic Generation Experiment; BNL Maglev Studies; Structural Investigations of Pt-Based Catalysts; Studies on the Cellular Toxicity of Cocaine and Cocaethylene; Human Melanocyte Transformation; Exploratory Applications of X-Ray Microscopy; Determination of the Higher Ordered Structure of Eukaryotic Chromosomes; Uranium Neutron Capture Therapy; Tunneling Microscopy Studies of Nanoscale Structures; Nuclear Techiques for Study of Biological Channels; RF Sources for Accelerator Physics; Induction and Repair of Double-Strand Breaks in the DNA of Human Lymphocytes; and An EBIS Source of High Charge State Ions up to Uranium.« less

  13. Metal–organic framework based mixed matrix membranes: a solution for highly efficient CO2 capture?† †Electronic supplementary information (ESI) available. See DOI: 10.1039/c4cs00437j Click here for additional data file.

    PubMed Central

    Seoane, Beatriz; Coronas, Joaquin; Gascon, Ignacio; Benavides, Miren Etxeberria; Karvan, Oğuz; Caro, Jürgen; Kapteijn, Freek

    2015-01-01

    The field of metal–organic framework based mixed matrix membranes (M4s) is critically reviewed, with special emphasis on their application in CO2 capture during energy generation. After introducing the most relevant parameters affecting membrane performance, we define targets in terms of selectivity and productivity based on existing literature on process design for pre- and post-combustion CO2 capture. Subsequently, the state of the art in M4s is reviewed against these targets. Because final application of these membranes will only be possible if thin separation layers can be produced, the latest advances in the manufacture of M4 hollow fibers are discussed. Finally, the recent efforts in understanding the separation performance of these complex composite materials and future research directions are outlined. PMID:25692487

  14. Electrochemistry-based Battery Modeling for Prognostics

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew J.; Kulkarni, Chetan Shrikant

    2013-01-01

    Batteries are used in a wide variety of applications. In recent years, they have become popular as a source of power for electric vehicles such as cars, unmanned aerial vehicles, and commericial passenger aircraft. In such application domains, it becomes crucial to both monitor battery health and performance and to predict end of discharge (EOD) and end of useful life (EOL) events. To implement such technologies, it is crucial to understand how batteries work and to capture that knowledge in the form of models that can be used by monitoring, diagnosis, and prognosis algorithms. In this work, we develop electrochemistry-based models of lithium-ion batteries that capture the significant electrochemical processes, are computationally efficient, capture the effects of aging, and are of suitable accuracy for reliable EOD prediction in a variety of usage profiles. This paper reports on the progress of such a model, with results demonstrating the model validity and accurate EOD predictions.

  15. Doped phosphorene for hydrogen capture: A DFT study

    NASA Astrophysics Data System (ADS)

    Zhang, Hong-ping; Hu, Wei; Du, Aijun; Lu, Xiong; Zhang, Ya-ping; Zhou, Jian; Lin, Xiaoyan; Tang, Youhong

    2018-03-01

    Hydrogen capture and storage is the core of hydrogen energy application. With its high specific surface area, direct bandgap, and variety of potential applications, phosphorene has attracted much research interest. In this study, density functional theory (DFT) is utilized to study the interactions between doped phosphorenes and hydrogen molecules. The effects of different dopants and metallic or nonmetallic atoms on phosphorene/hydrogen interactions is systematically studied by adsorption energy, electron density difference, partial density of states analysis, and Hirshfeld population. Our results indicate that the metallic dopants Pt, Co, and Ni can help to improve the hydrogen capture ability of phosphorene, whereas the nonmetallic dopants have no effect on it. Among the various metallic dopants, Pt performs very differently, such that it can help to dissociate H2 on phosphorene. Specified doped phosphorene could be a promising candidate for hydrogen storage, with behaviors superior to those of intrinsic graphene sheet.

  16. Pre-Capture Privacy for Small Vision Sensors.

    PubMed

    Pittaluga, Francesco; Koppal, Sanjeev Jagannatha

    2017-11-01

    The next wave of micro and nano devices will create a world with trillions of small networked cameras. This will lead to increased concerns about privacy and security. Most privacy preserving algorithms for computer vision are applied after image/video data has been captured. We propose to use privacy preserving optics that filter or block sensitive information directly from the incident light-field before sensor measurements are made, adding a new layer of privacy. In addition to balancing the privacy and utility of the captured data, we address trade-offs unique to miniature vision sensors, such as achieving high-quality field-of-view and resolution within the constraints of mass and volume. Our privacy preserving optics enable applications such as depth sensing, full-body motion tracking, people counting, blob detection and privacy preserving face recognition. While we demonstrate applications on macro-scale devices (smartphones, webcams, etc.) our theory has impact for smaller devices.

  17. Laser Capture Microdissection Revisited as a Tool for Transcriptomic Analysis: Application of an Excel-Based qPCR Preparation Software (PREXCEL-Q)

    USDA-ARS?s Scientific Manuscript database

    The ability to reliably analyze cellular and molecular profiles of normal or diseased tissues is frequently obfuscated by the inherent heterogeneous nature of tissues. Laser Capture Microdissection (LCM) is an innovative technique that allows the isolation and enrichment of pure subpopulations of c...

  18. Understanding perception of wood household furniture: application of a policy capturing approach

    Treesearch

    David Brinberg; Matthew Bumgardner; Kim Daniloski

    2007-01-01

    Consumer and retailer perceptions of wood household furniture were modeled using a policy capturing approach. A sample of consumers and retailers evaluated four pictures of wood furniture on eight visual cues deemed representative of the furniture purchasing environment. These cues were then regressed on respondents' judgment of willingness to pay for each...

  19. Study of the Effectiveness of OCR for Decentralized Data Capture and Conversion. Final Report.

    ERIC Educational Resources Information Center

    Liston, David M.; And Others

    The ERIC network conversion to an OCR (Optical Character Recognition) mode of data entry was studied to analyze the potential effectiveness of OCR data entry for future EPC/s (Editorial Processing Centers). Study results are also applicable to any other system involving decentralized bibliographic data capture and conversion functions. The report…

  20. What's in a Name? Degree Programs and What They Tell Us about "Applied Linguistics" in Australia

    ERIC Educational Resources Information Center

    Murray, Neil; Crichton, Jonathan

    2010-01-01

    In this paper we explore the provision of applied linguistics within Australian universities. We focus on how the "what" of applied linguistics, as captured in scholarly definitions of the discipline, accords with the "where", as captured in potential contexts of application as these are manifested in provision. In doing so, we…

  1. Geant4 beam model for boron neutron capture therapy: investigation of neutron dose components.

    PubMed

    Moghaddasi, Leyla; Bezak, Eva

    2018-03-01

    Boron neutron capture therapy (BNCT) is a biochemically-targeted type of radiotherapy, selectively delivering localized dose to tumour cells diffused in normal tissue, while minimizing normal tissue toxicity. BNCT is based on thermal neutron capture by stable [Formula: see text]B nuclei resulting in emission of short-ranged alpha particles and recoil [Formula: see text]Li nuclei. The purpose of the current work was to develop and validate a Monte Carlo BNCT beam model and to investigate contribution of individual dose components resulting of neutron interactions. A neutron beam model was developed in Geant4 and validated against published data. The neutron beam spectrum, obtained from literature for a cyclotron-produced beam, was irradiated to a water phantom with boron concentrations of 100 μg/g. The calculated percentage depth dose curves (PDDs) in the phantom were compared with published data to validate the beam model in terms of total and boron depth dose deposition. Subsequently, two sensitivity studies were conducted to quantify the impact of: (1) neutron beam spectrum, and (2) various boron concentrations on the boron dose component. Good agreement was achieved between the calculated and measured neutron beam PDDs (within 1%). The resulting boron depth dose deposition was also in agreement with measured data. The sensitivity study of several boron concentrations showed that the calculated boron dose gradually converged beyond 100 μg/g boron concentration. This results suggest that 100μg/g tumour boron concentration may be optimal and above this value limited increase in boron dose is expected for a given neutron flux.

  2. Rational Emotive Behavior Therapy: Origins, Constructs, and Applications.

    ERIC Educational Resources Information Center

    Watson, Joshua C.

    In 1956, Dr. Albert Ellis presented his seminal work on Rational Therapy, subsequently renamed Rational Emotive Behavior Therapy (REBT) in 1993. This paper explores the origins, theoretical foundations, applications, and implications of REBT and provides a look at the empirical research available in support of the approach's efficacy. REBT is…

  3. Treatment Planning for Accelerator-Based Boron Neutron Capture Therapy

    NASA Astrophysics Data System (ADS)

    Herrera, María S.; González, Sara J.; Minsky, Daniel M.; Kreiner, Andrés J.

    2010-08-01

    Glioblastoma multiforme and metastatic melanoma are frequent brain tumors in adults and presently still incurable diseases. Boron Neutron Capture Therapy (BNCT) is a promising alternative for this kind of pathologies. Accelerators have been proposed for BNCT as a way to circumvent the problem of siting reactors in hospitals and for their relative simplicity and lower cost among other advantages. Considerable effort is going into the development of accelerator-based BNCT neutron sources in Argentina. Epithermal neutron beams will be produced through appropriate proton-induced nuclear reactions and optimized beam shaping assemblies. Using these sources, computational dose distributions were evaluated in a real patient with diagnosed glioblastoma treated with BNCT. The simulated irradiation was delivered in order to optimize dose to the tumors within the normal tissue constraints. Using Monte Carlo radiation transport calculations, dose distributions were generated for brain, skin and tumor. Also, the dosimetry was studied by computing cumulative dose-volume histograms for volumes of interest. The results suggest acceptable skin average dose and a significant dose delivered to tumor with low average whole brain dose for irradiation times less than 60 minutes, indicating a good performance of an accelerator-based BNCT treatment.

  4. Nanostructured Boron Nitride With High Water Dispersibility For Boron Neutron Capture Therapy

    PubMed Central

    Singh, Bikramjeet; Kaur, Gurpreet; Singh, Paviter; Singh, Kulwinder; Kumar, Baban; Vij, Ankush; Kumar, Manjeet; Bala, Rajni; Meena, Ramovatar; Singh, Ajay; Thakur, Anup; Kumar, Akshay

    2016-01-01

    Highly water dispersible boron based compounds are innovative and advanced materials which can be used in Boron Neutron Capture Therapy for cancer treatment (BNCT). Present study deals with the synthesis of highly water dispersible nanostructured Boron Nitride (BN). Unique and relatively low temperature synthesis route is the soul of present study. The morphological examinations (Scanning/transmission electron microscopy) of synthesized nanostructures showed that they are in transient phase from two dimensional hexagonal sheets to nanotubes. It is also supported by dual energy band gap of these materials calculated from UV- visible spectrum of the material. The theoretically calculated band gap also supports the same (calculated by virtual nano lab Software). X-ray diffraction (XRD) analysis shows that the synthesized material has deformed structure which is further supported by Raman spectroscopy. The structural aspect of high water disperse ability of BN is also studied. The ultra-high disperse ability which is a result of structural deformation make these nanostructures very useful in BNCT. Cytotoxicity studies on various cell lines (Hela(cervical cancer), human embryonic kidney (HEK-293) and human breast adenocarcinoma (MCF-7)) show that the synthesized nanostructures can be used for BNCT. PMID:27759052

  5. Treatment Planning for Accelerator-Based Boron Neutron Capture Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herrera, Maria S.; Gonzalez, Sara J.; Minsky, Daniel M.

    2010-08-04

    Glioblastoma multiforme and metastatic melanoma are frequent brain tumors in adults and presently still incurable diseases. Boron Neutron Capture Therapy (BNCT) is a promising alternative for this kind of pathologies. Accelerators have been proposed for BNCT as a way to circumvent the problem of siting reactors in hospitals and for their relative simplicity and lower cost among other advantages. Considerable effort is going into the development of accelerator-based BNCT neutron sources in Argentina. Epithermal neutron beams will be produced through appropriate proton-induced nuclear reactions and optimized beam shaping assemblies. Using these sources, computational dose distributions were evaluated in a realmore » patient with diagnosed glioblastoma treated with BNCT. The simulated irradiation was delivered in order to optimize dose to the tumors within the normal tissue constraints. Using Monte Carlo radiation transport calculations, dose distributions were generated for brain, skin and tumor. Also, the dosimetry was studied by computing cumulative dose-volume histograms for volumes of interest. The results suggest acceptable skin average dose and a significant dose delivered to tumor with low average whole brain dose for irradiation times less than 60 minutes, indicating a good performance of an accelerator-based BNCT treatment.« less

  6. Sonoporation as an enhancing method for boron neutron capture therapy for squamous cell carcinomas

    PubMed Central

    2013-01-01

    Background Boron neutron capture therapy (BNCT) is a selective radiotherapy that is dependent on the accumulation of 10B compound in tumors. Low-intensity ultrasound produces a transient pore on cell membranes, sonoporation, which enables extracellular materials to enter cells. The effect of sonoporation on BNCT was examined in oral squamous cell carcinoma (SCC) xenografts in nude mice. Materials and methods Tumor-bearing mice were administrated boronophenylalanine (BPA) or boronocaptate sodium (BSH) intraperitoneally. Two hours later, tumors were subjected to sonoporation using microbubbles followed by neutron irradiation. Results The 10B concentration was higher in tumors treated with sonoporation than in untreated tumors, although the difference was not significant in BPA. When tumors in mice that received BPA intraperitoneally were treated with sonoporation followed by exposure to thermal neutrons, tumor volume was markedly reduced and the survival rate was prolonged. Such enhancements by sonoporation were not observed in mice treated with BSH-mediated BNCT. Conclusions These results indicate that sonoporation enhances the efficiency of BPA-mediated BNCT for oral SCC. Sonoporation may modulate the microlocalization of BPA and BSH in tumors and increase their intracellular levels. PMID:24295213

  7. Assessing advantages of sequential boron neutron capture therapy (BNCT) in an oral cancer model with normalized blood vessels.

    PubMed

    Molinari, Ana J; Thorp, Silvia I; Portu, Agustina M; Saint Martin, Gisela; Pozzi, Emiliano C C; Heber, Elisa M; Bortolussi, Silva; Itoiz, Maria E; Aromando, Romina F; Monti Hughes, Andrea; Garabalino, Marcela A; Altieri, Saverio; Trivillin, Verónica A; Schwint, Amanda E

    2015-01-01

    We previously demonstrated the therapeutic success of sequential boron neutron capture therapy (Seq-BNCT) in the hamster cheek pouch oral cancer model. It consists of BPA-BNCT followed by GB-10-BNCT 24 or 48 hours later. Additionally, we proved that tumor blood vessel normalization with thalidomide prior to BPA-BNCT improves tumor control. The aim of the present study was to evaluate the therapeutic efficacy and explore potential boron microdistribution changes in Seq-BNCT preceded by tumor blood vessel normalization. Tumor bearing animals were treated with thalidomide for tumor blood vessel normalization, followed by Seq-BNCT (Th+ Seq-BNCT) or Seq-Beam Only (Th+ Seq-BO) in the window of normalization. Boron microdistribution was assessed by neutron autoradiography. Th+ Seq-BNCT induced overall tumor response of 100%, with 87 (4)% complete tumor response. No cases of severe mucositis in dose-limiting precancerous tissue were observed. Differences in boron homogeneity between tumors pre-treated and not pre-treated with thalidomide were observed. Th+ Seq-BNCT achieved, for the first time, response in all treated tumors. Increased homogeneity in tumor boron microdistribution is associated to an improvement in tumor control.

  8. Predicted performance of a PG-SPECT system using CZT primary detectors and secondary Compton-suppression anti-coincidence detectors under near-clinical settings for boron neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Hales, Brian; Katabuchi, Tatsuya; Igashira, Masayuki; Terada, Kazushi; Hayashizaki, Noriyosu; Kobayashi, Tooru

    2017-12-01

    A test version of a prompt-gamma single photon emission computed tomography (PG-SPECT) system for boron neutron capture therapy (BNCT) using a CdZnTe (CZT) semiconductor detector with a secondary BGO anti-Compton suppression detector has been designed. A phantom with healthy tissue region of pure water, and 2 tumor regions of 5 wt% borated polyethylene was irradiated to a fluence of 1.3 × 109 n/cm2. The number of 478 keV foreground, background, and net counts were measured for each detector position and angle. Using only experimentally measured net counts, an image of the 478 keV production from the 10B(n , α) 7Li* reaction was reconstructed. Using Monte Carlo simulation and the experimentally measured background counts, the reliability of the system under clinically accurate parameters was extrapolated. After extrapolation, it was found that the value of the maximum-value pixel in the reconstructed 478 keV γ-ray production image overestimates the simulated production by an average of 9.2%, and that the standard deviation associated with the same value is 11.4%.

  9. Intracavitary moderator balloon combined with (252)Cf brachytherapy and boron neutron capture therapy, improving dosimetry in brain tumour and infiltrations.

    PubMed

    Brandão, S F; Campos, T P R

    2015-07-01

    This article proposes a combination of californium-252 ((252)Cf) brachytherapy, boron neutron capture therapy (BNCT) and an intracavitary moderator balloon catheter applied to brain tumour and infiltrations. Dosimetric evaluations were performed on three protocol set-ups: (252)Cf brachytherapy combined with BNCT (Cf-BNCT); Cf-BNCT with a balloon catheter filled with light water (LWB) and the same set-up with heavy water (HWB). Cf-BNCT-HWB has presented dosimetric advantages to Cf-BNCT-LWB and Cf-BNCT in infiltrations at 2.0-5.0 cm from the balloon surface. However, Cf-BNCT-LWB has shown superior dosimetry up to 2.0 cm from the balloon surface. Cf-BNCT-HWB and Cf-BNCT-LWB protocols provide a selective dose distribution for brain tumour and infiltrations, mainly further from the (252)Cf source, sparing the normal brain tissue. Malignant brain tumours grow rapidly and often spread to adjacent brain tissues, leading to death. Improvements in brain radiation protocols have been continuously achieved; however, brain tumour recurrence is observed in most cases. Cf-BNCT-LWB and Cf-BNCT-HWB represent new modalities for selectively combating brain tumour infiltrations and metastasis.

  10. Nanostructured Boron Nitride With High Water Dispersibility For Boron Neutron Capture Therapy

    NASA Astrophysics Data System (ADS)

    Singh, Bikramjeet; Kaur, Gurpreet; Singh, Paviter; Singh, Kulwinder; Kumar, Baban; Vij, Ankush; Kumar, Manjeet; Bala, Rajni; Meena, Ramovatar; Singh, Ajay; Thakur, Anup; Kumar, Akshay

    2016-10-01

    Highly water dispersible boron based compounds are innovative and advanced materials which can be used in Boron Neutron Capture Therapy for cancer treatment (BNCT). Present study deals with the synthesis of highly water dispersible nanostructured Boron Nitride (BN). Unique and relatively low temperature synthesis route is the soul of present study. The morphological examinations (Scanning/transmission electron microscopy) of synthesized nanostructures showed that they are in transient phase from two dimensional hexagonal sheets to nanotubes. It is also supported by dual energy band gap of these materials calculated from UV- visible spectrum of the material. The theoretically calculated band gap also supports the same (calculated by virtual nano lab Software). X-ray diffraction (XRD) analysis shows that the synthesized material has deformed structure which is further supported by Raman spectroscopy. The structural aspect of high water disperse ability of BN is also studied. The ultra-high disperse ability which is a result of structural deformation make these nanostructures very useful in BNCT. Cytotoxicity studies on various cell lines (Hela(cervical cancer), human embryonic kidney (HEK-293) and human breast adenocarcinoma (MCF-7)) show that the synthesized nanostructures can be used for BNCT.

  11. Capturing intraoperative deformations: research experience at Brigham and Women's Hospital.

    PubMed

    Warfield, Simon K; Haker, Steven J; Talos, Ion-Florin; Kemper, Corey A; Weisenfeld, Neil; Mewes, Andrea U J; Goldberg-Zimring, Daniel; Zou, Kelly H; Westin, Carl-Fredrik; Wells, William M; Tempany, Clare M C; Golby, Alexandra; Black, Peter M; Jolesz, Ferenc A; Kikinis, Ron

    2005-04-01

    During neurosurgical procedures the objective of the neurosurgeon is to achieve the resection of as much diseased tissue as possible while achieving the preservation of healthy brain tissue. The restricted capacity of the conventional operating room to enable the surgeon to visualize critical healthy brain structures and tumor margin has lead, over the past decade, to the development of sophisticated intraoperative imaging techniques to enhance visualization. However, both rigid motion due to patient placement and nonrigid deformations occurring as a consequence of the surgical intervention disrupt the correspondence between preoperative data used to plan surgery and the intraoperative configuration of the patient's brain. Similar challenges are faced in other interventional therapies, such as in cryoablation of the liver, or biopsy of the prostate. We have developed algorithms to model the motion of key anatomical structures and system implementations that enable us to estimate the deformation of the critical anatomy from sequences of volumetric images and to prepare updated fused visualizations of preoperative and intraoperative images at a rate compatible with surgical decision making. This paper reviews the experience at Brigham and Women's Hospital through the process of developing and applying novel algorithms for capturing intraoperative deformations in support of image guided therapy.

  12. Accelerator-based neutron source for boron neutron capture therapy (BNCT) and method

    DOEpatents

    Yoon, W.Y.; Jones, J.L.; Nigg, D.W.; Harker, Y.D.

    1999-05-11

    A source for boron neutron capture therapy (BNCT) comprises a body of photoneutron emitter that includes heavy water and is closely surrounded in heat-imparting relationship by target material; one or more electron linear accelerators for supplying electron radiation having energy of substantially 2 to 10 MeV and for impinging such radiation on the target material, whereby photoneutrons are produced and heat is absorbed from the target material by the body of photoneutron emitter. The heavy water is circulated through a cooling arrangement to remove heat. A tank, desirably cylindrical or spherical, contains the heavy water, and a desired number of the electron accelerators circumferentially surround the tank and the target material as preferably made up of thin plates of metallic tungsten. Neutrons generated within the tank are passed through a surrounding region containing neutron filtering and moderating materials and through neutron delimiting structure to produce a beam or beams of epithermal neutrons normally having a minimum flux intensity level of 1.0{times}10{sup 9} neutrons per square centimeter per second. Such beam or beams of epithermal neutrons are passed through gamma ray attenuating material to provide the required epithermal neutrons for BNCT use. 3 figs.

  13. Closing the Loop in ICU Decision Support: Physiologic Event Detection, Alerts, and Documentation

    PubMed Central

    Norris, Patrick R.; Dawant, Benoit M.

    2002-01-01

    Automated physiologic event detection and alerting is a challenging task in the ICU. Ideally care providers should be alerted only when events are clinically significant and there is opportunity for corrective action. However, the concepts of clinical significance and opportunity are difficult to define in automated systems, and effectiveness of alerting algorithms is difficult to measure. This paper describes recent efforts on the Simon project to capture information from ICU care providers about patient state and therapy in response to alerts, in order to assess the value of event definitions and progressively refine alerting algorithms. Event definitions for intracranial pressure and cerebral perfusion pressure were studied by implementing a reliable system to automatically deliver alerts to clinical users’ alphanumeric pagers, and to capture associated documentation about patient state and therapy when the alerts occurred. During a 6-month test period in the trauma ICU at Vanderbilt University Medical Center, 530 alerts were detected in 2280 hours of data spanning 14 patients. Clinical users electronically documented 81% of these alerts as they occurred. Retrospectively classifying documentation based on therapeutic actions taken, or reasons why actions were not taken, provided useful information about ways to potentially improve event definitions and enhance system utility.

  14. Accelerator-based neutron source for boron neutron capture therapy (BNCT) and method

    DOEpatents

    Yoon, Woo Y.; Jones, James L.; Nigg, David W.; Harker, Yale D.

    1999-01-01

    A source for boron neutron capture therapy (BNCT) comprises a body of photoneutron emitter that includes heavy water and is closely surrounded in heat-imparting relationship by target material; one or more electron linear accelerators for supplying electron radiation having energy of substantially 2 to 10 MeV and for impinging such radiation on the target material, whereby photoneutrons are produced and heat is absorbed from the target material by the body of photoneutron emitter. The heavy water is circulated through a cooling arrangement to remove heat. A tank, desirably cylindrical or spherical, contains the heavy water, and a desired number of the electron accelerators circumferentially surround the tank and the target material as preferably made up of thin plates of metallic tungsten. Neutrons generated within the tank are passed through a surrounding region containing neutron filtering and moderating materials and through neutron delimiting structure to produce a beam or beams of epithermal neutrons normally having a minimum flux intensity level of 1.0.times.10.sup.9 neutrons per square centimeter per second. Such beam or beams of epithermal neutrons are passed through gamma ray attenuating material to provide the required epithermal neutrons for BNCT use.

  15. Using Conversation Topics for Predicting Therapy Outcomes in Schizophrenia

    PubMed Central

    Howes, Christine; Purver, Matthew; McCabe, Rose

    2013-01-01

    Previous research shows that aspects of doctor-patient communication in therapy can predict patient symptoms, satisfaction and future adherence to treatment (a significant problem with conditions such as schizophrenia). However, automatic prediction has so far shown success only when based on low-level lexical features, and it is unclear how well these can generalize to new data, or whether their effectiveness is due to their capturing aspects of style, structure or content. Here, we examine the use of topic as a higher-level measure of content, more likely to generalize and to have more explanatory power. Investigations show that while topics predict some important factors such as patient satisfaction and ratings of therapy quality, they lack the full predictive power of lower-level features. For some factors, unsupervised methods produce models comparable to manual annotation. PMID:23943658

  16. Topical Application of Liposomal Antioxidant’s for Protection Against CEES Induced Skin Damage

    DTIC Science & Technology

    2006-07-01

    14. ABSTRACT The objective of this study is to develop an effective prophylactic therapy against an analog of mustard gas, 2-chloroethylethyl...sulfide (CEES). The therapy for CEES-induced skin damage will be based on the topical application of antioxidant liposomes. We will use EpiDerm cultured...to develop an effective prophylactic therapy against CEES-induced skin damage (analogous to HD effect) based on the topical application of

  17. Theoretical calculating the thermodynamic properties of solid sorbents for CO{sub 2} capture applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duan, Yuhua

    2012-11-02

    Since current technologies for capturing CO{sub 2} to fight global climate change are still too energy intensive, there is a critical need for development of new materials that can capture CO{sub 2} reversibly with acceptable energy costs. Accordingly, solid sorbents have been proposed to be used for CO{sub 2} capture applications through a reversible chemical transformation. By combining thermodynamic database mining with first principles density functional theory and phonon lattice dynamics calculations, a theoretical screening methodology to identify the most promising CO{sub 2} sorbent candidates from the vast array of possible solid materials has been proposed and validated. The calculatedmore » thermodynamic properties of different classes of solid materials versus temperature and pressure changes were further used to evaluate the equilibrium properties for the CO{sub 2} adsorption/desorption cycles. According to the requirements imposed by the pre- and post- combustion technologies and based on our calculated thermodynamic properties for the CO{sub 2} capture reactions by the solids of interest, we were able to screen only those solid materials for which lower capture energy costs are expected at the desired pressure and temperature conditions. Only those selected CO{sub 2} sorbent candidates were further considered for experimental validations. The ab initio thermodynamic technique has the advantage of identifying thermodynamic properties of CO{sub 2} capture reactions without any experimental input beyond crystallographic structural information of the solid phases involved. Such methodology not only can be used to search for good candidates from existing database of solid materials, but also can provide some guidelines for synthesis new materials. In this presentation, we first introduce our screening methodology and the results on a testing set of solids with known thermodynamic properties to validate our methodology. Then, by applying our computational method to several different kinds of solid systems, we demonstrate that our methodology can predict the useful information to help developing CO{sub 2} capture Technologies.« less

  18. A review of research into the uses of low level ultrasound in cancer therapy.

    PubMed

    Yu, Tinghe; Wang, Zhibiao; Mason, Timothy J

    2004-04-01

    The use of low power ultrasound in therapeutic medicine is a developing field and this review will concentrate on the applications of this technology in cancer therapy. The effects of low power ultrasound have been evaluated in terms of the biological changes induced in the structure and function of tissue. The main fields of study have been in sonodynamic therapy, improving chemotherapy, gene therapy and apoptosis therapy. The range of ultrasonic power levels that can be effectively employed in therapy appears to be narrow and this may have hindered past research in the applications in cancer treatment.

  19. SU-E-T-21: A D-D Based Neutron Generator System for Boron Neutron Capture Therapy: A Feasibility Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsieh, M; Liu, Y; Nie, L

    2015-06-15

    Purpose: To investigate the feasibility of a deuterium-deuterium (DD) neutron generator for application in boron neutron capture therapy (BNCT) of brain cancer Methods: MCNP simulations were performed using a head phantom and a monoenergetic neutron source, which resembles the point source in a DD generator that emits 2.45-MeV neutrons. Source energies ranging from 5eV to 2.45MeV were simulated to determine the optimal treatment energy. The phantom consisted of soft tissue, brain tissue, skull, skin layer, and a brain tumor of 5 cm in diameter. Tumor depth was varied from 5–10 cm. Boron-10 concentrations of 10 ppm, 15 ppm, and 30more » ppm were used in the soft/brain tissues, skin, and tumor, respectively. The neutron flux required to deliver 60 Gy to the tumor as well as the normal tissue doses were determined. Results: Beam energies between 5eV and 10keV obtained doses with the highest dose ratios (3.3–25.9) between the tumor and the brain at various depths. The dose ratio with 2.45-MeV neutrons ranged from 0.8–6.6. To achieve the desired tumor dose in 40 minutes, the required neutron flux for a DD generator was between 8.8E10 and 5.2E11 n/s and the resulting brain dose was between 2.3 and 18 Gy, depending on the tumor depth. The skin and soft tissue doses were within acceptable tolerances. The boron-neutron interaction accounted for 54–58% of the total dose. Conclusion: This study shows that the DD neutron generator can be a feasible neutron source for BNCT. The required neutron flux for treatment is achievable with the current DD neutron technology. With a well-designed beam shaping assembly and treatment geometry, the neutron flux can be further improved and a 60-Gy prescription can be accurately delivered to the target while maintaining tolerable normal tissue doses. Further experimental studies will be developed and conducted to validate the simulation results.« less

  20. Circulating tumor cells in localized prostate cancer: isolation, cultivation in vitro and relationship to T-stage and Gleason score.

    PubMed

    Kolostova, Katarina; Broul, Marek; Schraml, Jan; Cegan, Martin; Matkowski, Rafal; Fiutowski, Marek; Bobek, Vladimir

    2014-07-01

    The most promising near-term application of circulating tumor cells (CTCs) monitoring relates to the development of targeted cancer therapies, and the need to tailor such treatments to individual tumor characteristics. A high number of new innovative technologies to improve methods for detecting CTCs, with extraordinarily high sensitivity, have recently been presented. The identification and characterization of CTCs require extremely sensitive and specific methods that are able to isolate CTCs with the possibility of cultivation and downstream analysis of in vitro culture of separated CTCs. In this original research paper, we demonstrate that it is possible to isolate human CTCs from a patient with prostate cancer, with subsequent cultivation and proliferation in vitro. We show that the use of a filtration device implemented by MetaCell® can fulfil all the requirements mentioned above. Fifty-five patients with localized prostate cancer have so far been enrolled into the study. CTCs were detected in the blood samples of 28 (52%) out of the 55 patients. We report successful isolation of CTCs from patients with prostate cancer, capturing cells with a proliferative capacity in 18 (64.3%) out of the 28 CTC-positive patients. Direct correlation with Gleason score and T stage was not proven. The cells, captured by a size-based filtration approach, remain in a good state, unaffected by any antibodies or lysing solutions. During the filtration process, no interactions occurred between antibodies and antigens on the surface of CTCs. This biological interaction is specific for immunomagnetic methods. The MetaCell device provides the possibility of reaching virgin CTCs suitable for subsequent cultivation or single-cell analysis. This aspect will have an important impact on the future design of clinical trials testing new drugs against targets expressed on metastatic cancer cells. In addition to measurement of CTC counts, future trials with targeted therapies should also include the assessment of the specific therapeutic target on CTCs. Copyright© 2014 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

Top