Sample records for capture therapy problems

  1. A comparison of the COG and MCNP codes in computational neutron capture therapy modeling, Part I: boron neutron capture therapy models.

    PubMed

    Culbertson, C N; Wangerin, K; Ghandourah, E; Jevremovic, T

    2005-08-01

    The goal of this study was to evaluate the COG Monte Carlo radiation transport code, developed and tested by Lawrence Livermore National Laboratory, for neutron capture therapy related modeling. A boron neutron capture therapy model was analyzed comparing COG calculational results to results from the widely used MCNP4B (Monte Carlo N-Particle) transport code. The approach for computing neutron fluence rate and each dose component relevant in boron neutron capture therapy is described, and calculated values are shown in detail. The differences between the COG and MCNP predictions are qualified and quantified. The differences are generally small and suggest that the COG code can be applied for BNCT research related problems.

  2. Neutron therapy of cancer

    NASA Technical Reports Server (NTRS)

    Frigerio, N. A.; Nellans, H. N.; Shaw, M. J.

    1969-01-01

    Reports relate applications of neutrons to the problem of cancer therapy. The biochemical and biophysical aspects of fast-neutron therapy, neutron-capture and neutron-conversion therapy with intermediate-range neutrons are presented. Also included is a computer program for neutron-gamma radiobiology.

  3. Capturing and missing the patient's story through outcome measures: A thematic comparison of patient-generated items in PSYCHLOPS with CORE-OM and PHQ-9.

    PubMed

    Sales, Célia Md; Neves, Inês Td; Alves, Paula G; Ashworth, Mark

    2017-11-22

    There is increasing interest in individualized patient-reported outcome measures (I-PROMS), where patients themselves indicate the specific problems they want to address in therapy and these problems are used as items within the outcome measurement tool. This paper examined the extent to which 279 items reported in an I-PROM (PSYCHLOPS) added qualitative information which was not captured by two well-established outcome measures (CORE-OM and PHQ-9). Comparison of items was only conducted for patients scoring above the "caseness" threshold on the standardized measures. 107 patients were participating in therapy within addiction and general psychiatric clinical settings. Almost every patient (95%) reported at least one item whose content was not covered by PHQ-9, and 71% reported at least one item not covered by CORE-OM. Results demonstrate the relevance of individualized outcome assessment for capturing data describing the issues of greatest concern to patients, as nomothetic measures do not always seem to capture the whole story. © 2017 The Authors Health Expectations Published by John Wiley & Sons Ltd.

  4. A comparison of the COG and MCNP codes in computational neutron capture therapy modeling, Part II: gadolinium neutron capture therapy models and therapeutic effects.

    PubMed

    Wangerin, K; Culbertson, C N; Jevremovic, T

    2005-08-01

    The goal of this study was to evaluate the COG Monte Carlo radiation transport code, developed and tested by Lawrence Livermore National Laboratory, for gadolinium neutron capture therapy (GdNCT) related modeling. The validity of COG NCT model has been established for this model, and here the calculation was extended to analyze the effect of various gadolinium concentrations on dose distribution and cell-kill effect of the GdNCT modality and to determine the optimum therapeutic conditions for treating brain cancers. The computational results were compared with the widely used MCNP code. The differences between the COG and MCNP predictions were generally small and suggest that the COG code can be applied to similar research problems in NCT. Results for this study also showed that a concentration of 100 ppm gadolinium in the tumor was most beneficial when using an epithermal neutron beam.

  5. A theoretical model for the production of Ac-225 for cancer therapy by neutron capture transmutation of Ra-226.

    PubMed

    Melville, G; Melville, P

    2013-02-01

    Radium needles that were once implanted into tumours as a cancer treatment are now obsolete and constitute a radioactive waste problem, as their half-life is 1600 years. We are investigating the reduction of radium by transmutation by bombarding Ra-226 with high-energy neutrons from a neutron source to produce Ra-225 and hence Ac-225, which can be used as a generator to produce Bi-213 for use in 'Targeted Alpha Therapy' for cancer. This paper examines the possibility of producing Ac-225 by neutron capture using a theoretical model in which neutron energy is convoluted with the corresponding neutron cross sections of Ra-226. The total integrated yield can then be obtained. This study shows that an intense beam of high-energy neutrons could initiate neutron capture on Ra-226 to produce Ra-225 and hence practical amounts of Ac-225 and a useful reduction of Ra-226. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Accelerator-driven boron neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Edgecock, Rob

    2014-05-01

    Boron Neutron Capture Therapy is a binary treatment for certain types of cancer. It works by loading the cancerous cells with a boron-10 carrying compound. This isotope has a large cross-section for thermal neutrons, the reaction producing a lithium nucleus and alpha particle that kill the cell in which they are produced. Recent studies of the boron carrier compound indicate that the uptake process works best in particularly aggressive cancers. Most studied is glioblastoma multiforme and a trial using a combination of BNCT and X-ray radiotherapy has shown an increase of nearly a factor of two in mean survival over the state of the art. However, the main technical problem with BNCT remains producing a sufficient flux of neutrons for a reasonable treatment duration in a hospital environment. This paper discusses this issue.

  7. The Effect of Deep Brain Stimulation Therapy on Fear-Related Capture of Attention in Parkinson's Disease and Essential Tremor: A Comparison to Healthy Individuals.

    PubMed

    Camalier, Corrie R; McHugo, Maureen; Zald, David H; Neimat, Joseph S

    2018-01-01

    In addition to motor symptoms, Parkinson's disease (PD) involves significant non-motor sequelae, including disruptions in cognitive and emotional processing. Fear recognition appears to be affected both by the course of the disease and by a common interventional therapy, deep brain stimulation of the subthalamic nucleus (STN-DBS). Here, we examined if these effects extend to other aspects of emotional processing, such as attentional capture by negative emotional stimuli. Performance on an emotional attentional blink (EAB) paradigm, a common paradigm used to study emotional capture of attention, was examined in a cohort of individuals with PD, both on and off STN-DBS therapy (n=20). To contrast effects of healthy aging and other movement disorder and DBS targets, we also examined performance in a healthy elderly (n=20) and young (n=18) sample on the same task, and a sample diagnosed with Essential Tremor (ET) undergoing therapeutic deep brain stimulation of the ventral-intermediate nucleus (VIM-DBS, n=18). All four groups showed a robust attentional capture of emotional stimuli, irrespective of aging processes, movement disorder diagnosis, or stimulation. PD patients on average had overall worse performance, but this decrement in performance was not related to the emotional capture of attention. PD patients exhibited a robust EAB, indicating that the ability of emotion to direct attention remains intact in PD. Congruent with other recent data, these findings suggest that fear recognition deficits in PD may instead reflect a highly specific problem in recognition, rather than a general deficit in emotional processing of fearful stimuli.

  8. Perspectives of boron-neutron capture therapy of malignant brain tumors

    NASA Astrophysics Data System (ADS)

    Kanygin, V. V.; Kichigin, A. I.; Krivoshapkin, A. L.; Taskaev, S. Yu.

    2017-09-01

    Boron neutron capture therapy (BNCT) is characterized by a selective effect directly on the cells of malignant tumors. The carried out research showed the perspective of the given kind of therapy concerning malignant tumors of the brain. However, the introduction of BNCT into clinical practice is hampered by the lack of a single protocol for the treatment of patients and the difficulty in using nuclear reactors to produce a neutron beam. This problem can be solved by using a compact accelerator as a source of neutrons, with the possibility of installation in a medical institution. Such a neutron accelerator for BNCT was developed at Budker Institute of Nuclear Physics, Novosibirsk. A neutron beam was obtained on this accelerator, which fully complies with the requirements of BNCT, as confirmed by studies on cell cultures and experiments with laboratory animals. The conducted experiments showed the relative safety of the method with the absence of negative effects on cell cultures and living organisms, and also confirmed the effectiveness of BNCT for malignant brain tumors.

  9. Workshop on neutron capture therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fairchild, R.G.; Bond, V.P.

    1986-01-01

    Potentially optimal conditions for Neutron Capture Therapy (NCT) may soon be in hand due to the anticipated development of band-pass filtered beams relatively free of fast neutron contaminations, and of broadly applicable biomolecules for boron transport such as porphyrins and monoclonal antibodies. Consequently, a number of groups in the US are now devoting their efforts to exploring NCT for clinical application. The purpose of this Workshop was to bring these groups together to exchange views on significant problems of mutual interest, and to assure a unified and effective approach to the solutions. Several areas of preclinical investigation were deemed tomore » be necessary before it would be possible to initiate clinical studies. As neither the monomer nor the dimer of sulfhydryl boron hydride is unequivocally preferable at this time, studies on both compounds should be continued until one is proven superior.« less

  10. Boron containing compounds and their preparation and use in neutron capture therapy

    DOEpatents

    Gabel, D.

    1992-09-01

    The present invention pertains to boron containing thiouracil derivatives, their method of preparations, and their use in the therapy of malignant melanoma using boron neutron capture therapy. No Drawings

  11. Neutron capture therapy: Years of experimentation---Years of reflection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farr, L.E.

    1991-12-16

    This report describes early research on neutron capture therapy over a number of years, beginning in 1950, speaking briefly of patient treatments but dwelling mostly on interpretations of our animal experiments. This work carried out over eighteen years, beginning over forty years ago. Yet, it is only fitting to start by relating how neutron capture therapy became part of Brookhaven`s Medical Research Center program.

  12. Neutron capture therapy: Years of experimentation---Years of reflection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farr, L.E.

    1991-12-16

    This report describes early research on neutron capture therapy over a number of years, beginning in 1950, speaking briefly of patient treatments but dwelling mostly on interpretations of our animal experiments. This work carried out over eighteen years, beginning over forty years ago. Yet, it is only fitting to start by relating how neutron capture therapy became part of Brookhaven's Medical Research Center program.

  13. Thiourea derivatives, methods of their preparation and their use in neutron capture therapy of malignant melanoma

    DOEpatents

    Gabel, D.

    1991-06-04

    The present invention pertains to boron containing thiouracil derivatives, their method of preparations, and their use in the therapy of malignant melanoma using boron neutron capture therapy. No Drawings

  14. Dynamic Geometry Capture with a Multi-View Structured-Light System

    DTIC Science & Technology

    2014-12-19

    funding was never a problem during my studies . One of the best parts of my time at UC Berkeley has been working with colleagues within the Video and...scientific and medical applications such as quantifying improvement in physical therapy and measuring unnatural poses in ergonomic studies . Specifically... cases with limited scene texture. This direct generation of surface geometry provides us with a distinct advantage over multi-camera based systems. For

  15. Gadolinium as a Neutron Capture Therapy Agent

    NASA Astrophysics Data System (ADS)

    Shih, Jing-Luen Allen

    The clinical results of treating brain tumors with boron neutron capture therapy are very encouraging and researchers around the world are once again making efforts to develop this therapeutic modality. Boron-10 is the agent receiving the most attention for neutron capture therapy but ^{157}Gd is a nuclide that also holds interesting properties of being a neutron capture therapy agent. The objective of this study is to evaluate ^{157}Gd as a neutron capture therapy agent. In this study it is determined that tumor concentrations of about 300 mug ^{157}Gd/g tumor can be achieved in brain tumors with some FDA approved MRI contrast agents such as Gd-DTPA and Gd-DOTA, and up to 628 mug ^{157 }Gd/g tumor can be established in bone tumors with Gd-EDTMP. Monte Carlo calculations show that with only 250 ppm of ^{157}Gd in tumor, neutron capture therapy can deliver 2,000 cGy to a tumor of 2 cm diameter or larger with 5 times 10^{12} n/cm ^2 fluence at the tumor. Dose measurements which were made with films and TLD's in phantoms verified these calculations. More extended Monte Carlo calculations demonstrate that neutron capture therapy with Gd possesses comparable dose distribution to B neutron capture therapy. With 5 times 10^{12 } n/cm^2 thermal neutrons at the tumor, Auger electrons from the Gd produced an optical density enhancement on the films that is similar to the effect caused by about 300 cGy of Gd prompt gamma dose which will further enhance the therapeutic effects. A technique that combines brachytherapy with Gd neutron capture therapy has been evaluated. Monte Carlo calculations show that 5,000 cGy of prompt gamma dose can be delivered to a treatment volume of 40 cm^3 with a 3-plane implant of a total of 9 Gd needles. The tumor to normal tissue advantage of this method is as good as ^{60} Co brachytherapy. Measurements of prompt gamma dose with films and TLD-700's in a lucite phantom verify the Monte Carlo evaluation. A technique which displays the Gd distribution and its relative concentration in samples has been developed. Concentrations of ^{157}Gd in samples range from 20 ppm to 500 ppm can be determined with this technique. The intrinsic spatial resolution of the imaging system in 70 mum.

  16. Approach to magnetic neutron capture therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuznetsov, Anatoly A.; Podoynitsyn, Sergey N.; Filippov, Victor I.

    2005-11-01

    Purpose: The method of magnetic neutron capture therapy can be described as a combination of two methods: magnetic localization of drugs using magnetically targeted carriers and neutron capture therapy itself. Methods and Materials: In this work, we produced and tested two types of particles for such therapy. Composite ultradispersed ferro-carbon (Fe-C) and iron-boron (Fe-B) particles were formed from vapors of respective materials. Results: Two-component ultradispersed particles, containing Fe and C, were tested as magnetic adsorbent of L-boronophenylalanine and borax and were shown that borax sorption could be effective for creation of high concentration of boron atoms in the area ofmore » tumor. Kinetics of boron release into the physiologic solution demonstrate that ultradispersed Fe-B (10%) could be applied for an effective magnetic neutron capture therapy. Conclusion: Both types of the particles have high magnetization and magnetic homogeneity, allow to form stable magnetic suspensions, and have low toxicity.« less

  17. Using Conversation Topics for Predicting Therapy Outcomes in Schizophrenia

    PubMed Central

    Howes, Christine; Purver, Matthew; McCabe, Rose

    2013-01-01

    Previous research shows that aspects of doctor-patient communication in therapy can predict patient symptoms, satisfaction and future adherence to treatment (a significant problem with conditions such as schizophrenia). However, automatic prediction has so far shown success only when based on low-level lexical features, and it is unclear how well these can generalize to new data, or whether their effectiveness is due to their capturing aspects of style, structure or content. Here, we examine the use of topic as a higher-level measure of content, more likely to generalize and to have more explanatory power. Investigations show that while topics predict some important factors such as patient satisfaction and ratings of therapy quality, they lack the full predictive power of lower-level features. For some factors, unsupervised methods produce models comparable to manual annotation. PMID:23943658

  18. Gyrotron-driven high current ECR ion source for boron-neutron capture therapy neutron generator

    NASA Astrophysics Data System (ADS)

    Skalyga, V.; Izotov, I.; Golubev, S.; Razin, S.; Sidorov, A.; Maslennikova, A.; Volovecky, A.; Kalvas, T.; Koivisto, H.; Tarvainen, O.

    2014-12-01

    Boron-neutron capture therapy (BNCT) is a perspective treatment method for radiation resistant tumors. Unfortunately its development is strongly held back by a several physical and medical problems. Neutron sources for BNCT currently are limited to nuclear reactors and accelerators. For wide spread of BNCT investigations more compact and cheap neutron source would be much more preferable. In present paper an approach for compact D-D neutron generator creation based on a high current ECR ion source is suggested. Results on dense proton beams production are presented. A possibility of ion beams formation with current density up to 600 mA/cm2 is demonstrated. Estimations based on obtained experimental results show that neutron target bombarded by such deuteron beams would theoretically yield a neutron flux density up to 6·1010 cm-2/s. Thus, neutron generator based on a high-current deuteron ECR source with a powerful plasma heating by gyrotron radiation could fulfill the BNCT requirements significantly lower price, smaller size and ease of operation in comparison with existing reactors and accelerators.

  19. Halogenated sulfidohydroboranes for nuclear medicine and boron neutron capture therapy

    DOEpatents

    Miura, Michiko; Slatkin, Daniel N.

    1997-03-18

    A method for performing boron neutron capture therapy for the treatment of tumors is disclosed. The method includes administering to a patient an iodinated sulfidohydroborane, a boron-10-containing compound. The site of the tumor is localized by visualizing the increased concentration of the iodine labelled compound at the tumor. The targeted tumor is then irradiated with a beam of neutrons having an energy distribution effective for neutron capture. Destruction of the tumor occurs due to high LET particle irradiation of the tissue secondary to the incident neutrons being captured by the boron-10 nuclei. Iodinated sulfidohydroboranes are disclosed which are especially suitable for the method of the invention. In a preferred embodiment, a compound having the formula Na.sub.4 B.sub.12 I.sub.11 SSB.sub.12 I.sub.11, or another pharmaceutically acceptable salt of the compound, may be administered to a cancer patient for boron neutron capture therapy.

  20. Halogenated sulfidohydroboranes for nuclear medicine and boron neutron capture therapy

    DOEpatents

    Miura, Michiko; Slatkin, Daniel N.

    1995-10-03

    A method for performing boron neutron capture therapy for the treatment of tumors is disclosed. The method includes administering to a patient an iodinated sulfidohydroborane, a boron-10-containing compound. The site of the tumor is localized by visualizing the increased concentration of the iodine labelled compound at the tumor. The targeted tumor is then irradiated with a beam of neutrons having an energy distribution effective for neutron capture. Destruction of the tumor occurs due to high LET particle irradiation of the tissue secondary to the incident neutrons being captured by the boron-10 nuclei. Iodinated sulfidohydroboranes are disclosed which are especially suitable for the method of the invention. In a preferred embodiment, a compound having the formula Na.sub.4 B.sub.12 I.sub.11 SSB.sub.12 I.sub.11, or another pharmaceutically acceptable salt of the compound, may be administered to a cancer patient for boron neutron capture therapy.

  1. Halogenated sulfidohydroboranes for nuclear medicine and boron neutron capture therapy

    DOEpatents

    Miura, Michiko; Slatkin, Daniel N.

    1997-08-05

    A method for performing boron neutron capture therapy for the treatment of tumors is disclosed. The method includes administering to a patient an iodinated sulfidohydroborane, a boron-10-containing compound. The site of the tumor is localized. by visualizing the increased concentration of the iodine labelled compound at the tumor. The targeted tumor is then irradiated with a beam of neutrons having an energy distribution effective for neutron capture. Destruction of the tumor occurs due to high LET particle irradiation of the tissue secondary to the incident neutrons being captured by the boron-10 nuclei. Iodinated sulfidohydroboranes are disclosed which are especially suitable for the method of the invention. In a preferred embodiment, a compound having the formula Na.sub.4 B.sub.12 I.sub.11 SSB.sub.12 I.sub.11, or another pharmaceutically acceptable salt of the compound, may be administered to a cancer patient for boron neutron capture therapy.

  2. Halogenated sulfidohydroboranes for nuclear medicine and boron neutron capture therapy

    DOEpatents

    Miura, M.; Slatkin, D.N.

    1995-10-03

    A method for performing boron neutron capture therapy for the treatment of tumors is disclosed. The method includes administering to a patient an iodinated sulfidohydroborane, a boron-10-containing compound. The site of the tumor is localized by visualizing the increased concentration of the iodine labelled compound at the tumor. The targeted tumor is then irradiated with a beam of neutrons having an energy distribution effective for neutron capture. Destruction of the tumor occurs due to high LET particle irradiation of the tissue secondary to the incident neutrons being captured by the boron-10 nuclei. Iodinated sulfidohydroboranes are disclosed which are especially suitable for the method of the invention. In a preferred embodiment, a compound having the formula Na{sub 4}B{sub 12}I{sub 11}SSB{sub 12}I{sub 11}, or another pharmaceutically acceptable salt of the compound, may be administered to a cancer patient for boron neutron capture therapy. 1 fig.

  3. Halogenated sulfidohydroboranes for nuclear medicine and boron neutron capture therapy

    DOEpatents

    Miura, M.; Slatkin, D.N.

    1997-03-18

    A method for performing boron neutron capture therapy for the treatment of tumors is disclosed. The method includes administering to a patient an iodinated sulfidohydroborane, a boron-10-containing compound. The site of the tumor is localized by visualizing the increased concentration of the iodine labelled compound at the tumor. The targeted tumor is then irradiated with a beam of neutrons having an energy distribution effective for neutron capture. Destruction of the tumor occurs due to high LET particle irradiation of the tissue secondary to the incident neutrons being captured by the boron-10 nuclei. Iodinated sulfidohydroboranes are disclosed which are especially suitable for the method of the invention. In a preferred embodiment, a compound having the formula Na{sub 4}B{sub 12}I{sub 11}SSB{sub 12}I{sub 11}, or another pharmaceutically acceptable salt of the compound, may be administered to a cancer patient for boron neutron capture therapy. 1 fig.

  4. Halogenated sulfidohydroboranes for nuclear medicine and boron neutron capture therapy

    DOEpatents

    Miura, M.; Slatkin, D.N.

    1997-08-05

    A method for performing boron neutron capture therapy for the treatment of tumors is disclosed. The method includes administering to a patient an iodinated sulfidohydroborane, a boron-10-containing compound. The site of the tumor is localized by visualizing the increased concentration of the iodine labelled compound at the tumor. The targeted tumor is then irradiated with a beam of neutrons having an energy distribution effective for neutron capture. Destruction of the tumor occurs due to high LET particle irradiation of the tissue secondary to the incident neutrons being captured by the boron-10 nuclei. Iodinated sulfidohydroboranes are disclosed which are especially suitable for the method of the invention. In a preferred embodiment, a compound having the formula Na{sub 4}B{sub 12}I{sub 11}SSB{sub 12}I{sub 11}, or another pharmaceutically acceptable salt of the compound, may be administered to a cancer patient for boron neutron capture therapy. 1 fig.

  5. Neutron capture therapies

    DOEpatents

    Yanch, Jacquelyn C.; Shefer, Ruth E.; Klinkowstein, Robert E.

    1999-01-01

    In one embodiment there is provided an application of the .sup.10 B(n,.alpha.).sup.7 Li nuclear reaction or other neutron capture reactions for the treatment of rheumatoid arthritis. This application, called Boron Neutron Capture Synovectomy (BNCS), requires substantially altered demands on neutron beam design than for instance treatment of deep seated tumors. Considerations for neutron beam design for the treatment of arthritic joints via BNCS are provided for, and comparisons with the design requirements for Boron Neutron Capture Therapy (BNCT) of tumors are made. In addition, exemplary moderator/reflector assemblies are provided which produce intense, high-quality neutron beams based on (p,n) accelerator-based reactions. In another embodiment there is provided the use of deuteron-based charged particle reactions to be used as sources for epithermal or thermal neutron beams for neutron capture therapies. Many d,n reactions (e.g. using deuterium, tritium or beryllium targets) are very prolific at relatively low deuteron energies.

  6. Boron Neutron Capture Therapy in the Treatment of Locally Recurred Head and Neck Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kankaanranta, Leena; Seppaelae, Tiina; Koivunoro, Hanna

    2007-10-01

    Purpose: Head and neck carcinomas that recur locally after conventional irradiation pose a difficult therapeutic problem. We evaluated safety and efficacy of boron neutron capture therapy (BNCT) in the treatment of such cancers. Methods and Materials: Twelve patients with inoperable, recurred, locally advanced (rT3, rT4, or rN2) head and neck cancer were treated with BNCT in a prospective, single-center Phase I-II study. Prior treatments consisted of surgery and conventionally fractionated photon irradiation to a cumulative dose of 56-74 Gy administered with or without concomitant chemotherapy. Tumor responses were assessed using the RECIST (Response Evaluation Criteria in Solid Tumors) criteria andmore » adverse effects using the National Cancer Institute common toxicity grading v3.0. Intravenously administered boronophenylalanine-fructose (BPA-F, 400 mg/kg) was used as the boron carrier. Each patient was scheduled to be treated twice with BNCT. Results: Ten patients received BNCT twice; 2 were treated once. Ten (83%) patients responded to BNCT, and 2 (17%) had tumor growth stabilization for 5.5 and 7.6 months. The median duration of response was 12.1 months; six responses were ongoing at the time of analysis or death (range, 4.9-19.2 months). Four (33%) patients were alive without recurrence with a median follow-up of 14.0 months (range, 12.8-19.2 months). The most common acute adverse effects were mucositis, fatigue, and local pain; 2 patients had a severe (Grade 3) late adverse effect (xerostomia, 1; dysphagia, 1). Conclusions: Boron neutron capture therapy is effective and safe in the treatment of inoperable, locally advanced head and neck carcinomas that recur at previously irradiated sites.« less

  7. Cellular uptake and in vitro antitumor efficacy of composite liposomes for neutron capture therapy.

    PubMed

    Peters, Tanja; Grunewald, Catrin; Blaickner, Matthias; Ziegner, Markus; Schütz, Christian; Iffland, Dorothee; Hampel, Gabriele; Nawroth, Thomas; Langguth, Peter

    2015-02-22

    Neutron capture therapy for glioblastoma has focused mainly on the use of (10)B as neutron capture isotope. However, (157)Gd offers several advantages over boron, such as higher cross section for thermal neutrons and the possibility to perform magnetic resonance imaging during neutron irradiation, thereby combining therapy and diagnostics. We have developed different liposomal formulations of gadolinium-DTPA (Magnevist®) for application in neutron capture therapy of glioblastoma. The formulations were characterized physicochemically and tested in vitro in a glioma cell model for their effectiveness. Liposomes entrapping gadolinium-DTPA as neutron capture agent were manufactured via lipid/film-extrusion method and characterized with regard to size, entrapment efficiency and in vitro release. For neutron irradiation, F98 and LN229 glioma cells were incubated with the newly developed liposomes and subsequently irradiated at the thermal column of the TRIGA reactor in Mainz. The dose rate derived from neutron irradiation with (157)Gd as neutron capturing agent was calculated via Monte Carlo simulations and set in relation to the respective cell survival. The liposomal Gd-DTPA reduced cell survival of F98 and LN229 cells significantly. Differences in liposomal composition of the formulations led to distinctly different outcome in cell survival. The amount of cellular Gd was not at all times proportional to cell survival, indicating that intracellular deposition of formulated Gd has a major influence on cell survival. The majority of the dose contribution arises from photon cross irradiation compared to a very small Gd-related dose. Liposomal gadolinium formulations represent a promising approach for neutron capture therapy of glioblastoma cells. The liposome composition determines the uptake and the survival of cells following radiation, presumably due to different uptake pathways of liposomes and intracellular deposition of gadolinium-DTPA. Due to the small range of the Auger and conversion electrons produced in (157)Gd capture, the proximity of Gd-atoms to cellular DNA is a crucial factor for infliction of lethal damage. Furthermore, Gd-containing liposomes may be used as MRI contrast agents for diagnostic purposes and surveillance of tumor targeting, thus enabling a theranostic approach for tumor therapy.

  8. Treatment Planning for Accelerator-Based Boron Neutron Capture Therapy

    NASA Astrophysics Data System (ADS)

    Herrera, María S.; González, Sara J.; Minsky, Daniel M.; Kreiner, Andrés J.

    2010-08-01

    Glioblastoma multiforme and metastatic melanoma are frequent brain tumors in adults and presently still incurable diseases. Boron Neutron Capture Therapy (BNCT) is a promising alternative for this kind of pathologies. Accelerators have been proposed for BNCT as a way to circumvent the problem of siting reactors in hospitals and for their relative simplicity and lower cost among other advantages. Considerable effort is going into the development of accelerator-based BNCT neutron sources in Argentina. Epithermal neutron beams will be produced through appropriate proton-induced nuclear reactions and optimized beam shaping assemblies. Using these sources, computational dose distributions were evaluated in a real patient with diagnosed glioblastoma treated with BNCT. The simulated irradiation was delivered in order to optimize dose to the tumors within the normal tissue constraints. Using Monte Carlo radiation transport calculations, dose distributions were generated for brain, skin and tumor. Also, the dosimetry was studied by computing cumulative dose-volume histograms for volumes of interest. The results suggest acceptable skin average dose and a significant dose delivered to tumor with low average whole brain dose for irradiation times less than 60 minutes, indicating a good performance of an accelerator-based BNCT treatment.

  9. Treatment Planning for Accelerator-Based Boron Neutron Capture Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herrera, Maria S.; Gonzalez, Sara J.; Minsky, Daniel M.

    2010-08-04

    Glioblastoma multiforme and metastatic melanoma are frequent brain tumors in adults and presently still incurable diseases. Boron Neutron Capture Therapy (BNCT) is a promising alternative for this kind of pathologies. Accelerators have been proposed for BNCT as a way to circumvent the problem of siting reactors in hospitals and for their relative simplicity and lower cost among other advantages. Considerable effort is going into the development of accelerator-based BNCT neutron sources in Argentina. Epithermal neutron beams will be produced through appropriate proton-induced nuclear reactions and optimized beam shaping assemblies. Using these sources, computational dose distributions were evaluated in a realmore » patient with diagnosed glioblastoma treated with BNCT. The simulated irradiation was delivered in order to optimize dose to the tumors within the normal tissue constraints. Using Monte Carlo radiation transport calculations, dose distributions were generated for brain, skin and tumor. Also, the dosimetry was studied by computing cumulative dose-volume histograms for volumes of interest. The results suggest acceptable skin average dose and a significant dose delivered to tumor with low average whole brain dose for irradiation times less than 60 minutes, indicating a good performance of an accelerator-based BNCT treatment.« less

  10. Epithermal neutron beams from the 7 Li(p,n) reaction near the threshold for neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Porras, I.; Praena, J.; Arias de Saavedra, F.; Pedrosa, M.; Esquinas, P.; L. Jiménez-Bonilla, P.

    2016-11-01

    Two applications for neutron capture therapy of epithermal neutron beams calculated from the 7Li ( p , n reaction are discussed. In particular, i) for a proton beam of 1920 keV of a 30 mA, a neutron beam of adequate features for BNCT is found at an angle of 80° from the forward direction; and ii) for a proton beam of 1910 keV, a neutron beam is obtained at the forward direction suitable for performing radiobiology experiments for the determination of the biological weighting factors of the fast dose component in neutron capture therapy.

  11. In vivo evaluation of neutron capture therapy effectivity using calcium phosphate-based nanoparticles as Gd-DTPA delivery agent.

    PubMed

    Dewi, Novriana; Mi, Peng; Yanagie, Hironobu; Sakurai, Yuriko; Morishita, Yasuyuki; Yanagawa, Masashi; Nakagawa, Takayuki; Shinohara, Atsuko; Matsukawa, Takehisa; Yokoyama, Kazuhito; Cabral, Horacio; Suzuki, Minoru; Sakurai, Yoshinori; Tanaka, Hiroki; Ono, Koji; Nishiyama, Nobuhiro; Kataoka, Kazunori; Takahashi, Hiroyuki

    2016-04-01

    A more immediate impact for therapeutic approaches of current clinical research efforts is of major interest, which might be obtained by developing a noninvasive radiation dose-escalation strategy, and neutron capture therapy represents one such novel approach. Furthermore, some recent researches on neutron capture therapy have focused on using gadolinium as an alternative or complementary for currently used boron, taking into account several advantages that gadolinium offers. Therefore, in this study, we carried out feasibility evaluation for both single and multiple injections of gadolinium-based MRI contrast agent incorporated in calcium phosphate nanoparticles as neutron capture therapy agent. In vivo evaluation was performed on colon carcinoma Col-26 tumor-bearing mice irradiated at nuclear reactor facility of Kyoto University Research Reactor Institute with average neutron fluence of 1.8 × 10(12) n/cm(2). Antitumor effectivity was evaluated based on tumor growth suppression assessed until 27 days after neutron irradiation, followed by histopathological analysis on tumor slice. The experimental results showed that the tumor growth of irradiated mice injected beforehand with Gd-DTPA-incorporating calcium phosphate-based nanoparticles was suppressed up to four times higher compared to the non-treated group, supported by the results of histopathological analysis. The results of antitumor effectivity observed on tumor-bearing mice after neutron irradiation indicated possible effectivity of gadolinium-based neutron capture therapy treatment.

  12. Monte Carlo based dosimetry for neutron capture therapy of brain tumors

    NASA Astrophysics Data System (ADS)

    Zaidi, Lilia; Belgaid, Mohamed; Khelifi, Rachid

    2016-11-01

    Boron Neutron Capture Therapy (BNCT) is a biologically targeted, radiation therapy for cancer which combines neutron irradiation with a tumor targeting agent labeled with a boron10 having a high thermal neutron capture cross section. The tumor area is subjected to the neutron irradiation. After a thermal neutron capture, the excited 11B nucleus fissions into an alpha particle and lithium recoil nucleus. The high Linear Energy Transfer (LET) emitted particles deposit their energy in a range of about 10μm, which is of the same order of cell diameter [1], at the same time other reactions due to neutron activation with body component are produced. In-phantom measurement of physical dose distribution is very important for BNCT planning validation. Determination of total absorbed dose requires complex calculations which were carried out using the Monte Carlo MCNP code [2].

  13. Porphyrins for boron neutron capture therapy

    DOEpatents

    Miura, Michiko; Gabel, Detlef

    1990-01-01

    Novel compounds for treatment of brain tumors in Boron Neutron Capture Therapy are disclosed. A method for preparing the compounds as well as pharmaceutical compositions containing said compounds are also disclosed. The compounds are water soluble, non-toxic and non-labile boronated porphyrins which show significant uptake and retention in tumors.

  14. Insights into the use of gadolinium and gadolinium/boron-based agents in imaging-guided neutron capture therapy applications.

    PubMed

    Deagostino, Annamaria; Protti, Nicoletta; Alberti, Diego; Boggio, Paolo; Bortolussi, Silva; Altieri, Saverio; Crich, Simonetta Geninatti

    2016-05-01

    Gadolinium neutron capture therapy (Gd-NCT) is currently under development as an alternative approach for cancer therapy. All of the clinical experience to date with NCT is done with (10)B, known as boron neutron capture therapy (BNCT), a binary treatment combining neutron irradiation with the delivery of boron-containing compounds to tumors. Currently, the use of Gd for NCT has been getting more attention because of its highest neutron cross-section. Although Gd-NCT was first proposed many years ago, its development has suffered due to lack of appropriate tumor-selective Gd agents. This review aims to highlight the recent advances for the design, synthesis and biological testing of new Gd- and B-Gd-containing compounds with the task of finding the best systems able to improve the NCT clinical outcome.

  15. Direct and indirect capture of near-Earth asteroids in the Earth-Moon system

    NASA Astrophysics Data System (ADS)

    Tan, Minghu; McInnes, Colin; Ceriotti, Matteo

    2017-09-01

    Near-Earth asteroids have attracted attention for both scientific and commercial mission applications. Due to the fact that the Earth-Moon L1 and L2 points are candidates for gateway stations for lunar exploration, and an ideal location for space science, capturing asteroids and inserting them into periodic orbits around these points is of significant interest for the future. In this paper, we define a new type of lunar asteroid capture, termed direct capture. In this capture strategy, the candidate asteroid leaves its heliocentric orbit after an initial impulse, with its dynamics modeled using the Sun-Earth-Moon restricted four-body problem until its insertion, with a second impulse, onto the L2 stable manifold in the Earth-Moon circular restricted three-body problem. A Lambert arc in the Sun-asteroid two-body problem is used as an initial guess and a differential corrector used to generate the transfer trajectory from the asteroid's initial obit to the stable manifold associated with Earth-Moon L2 point. Results show that the direct asteroid capture strategy needs a shorter flight time compared to an indirect asteroid capture, which couples capture in the Sun-Earth circular restricted three-body problem and subsequent transfer to the Earth-Moon circular restricted three-body problem. Finally, the direct and indirect asteroid capture strategies are also applied to consider capture of asteroids at the triangular libration points in the Earth-Moon system.

  16. Theoretical and experimental physical methods of neutron-capture therapy

    NASA Astrophysics Data System (ADS)

    Borisov, G. I.

    2011-09-01

    This review is based to a substantial degree on our priority developments and research at the IR-8 reactor of the Russian Research Centre Kurchatov Institute. New theoretical and experimental methods of neutron-capture therapy are developed and applied in practice; these are: A general analytical and semi-empiric theory of neutron-capture therapy (NCT) based on classical neutron physics and its main sections (elementary theories of moderation, diffuse, reflection, and absorption of neutrons) rather than on methods of mathematical simulation. The theory is, first of all, intended for practical application by physicists, engineers, biologists, and physicians. This theory can be mastered by anyone with a higher education of almost any kind and minimal experience in operating a personal computer.

  17. Catch as Catch Can: The History of the Theory of Gravitational Capture.

    ERIC Educational Resources Information Center

    Osipov, Y.

    1992-01-01

    Traces cosmogonic history of solar system from Laplace's hypothesis of revolving gas nebulae, to Newton's two-body problem with its mathematical impossibility of gravitational capture, to the isosceles three-body problem of Schmidt and Sitnikov with its notion of partial capture, and finally to the total capture model of Alexeyev verified by the…

  18. Proceedings of the first international symposium on neutron capture therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fairchild, R.G.; Brownell, G.L.

    This meeting was arranged jointly by MIT and BNL in order to illuminate progress in the synthesis and targeting of boron compounds and to evaluate and document progress in radiobiological and dosimetric aspects of neutron capture therapy. It is hoped that this meeting will facilitate transfer of information between groups working in these fields, and encourage synergistic collaboration.

  19. Patient-directed therapy during in-patient stroke rehabilitation: stroke survivors' views of feasibility and acceptability.

    PubMed

    Horne, Maria; Thomas, Nessa; McCabe, Candy; Selles, Rudd; Vail, Andy; Tyrrell, Pippa; Tyson, Sarah

    2015-01-01

    Patient-led therapy, in which patients work outside therapy sessions without direct supervision, is a possible way to increase the amount of therapy stroke patients' receive without increasing staff demands. Here, we report patients' views of patient-led mirror therapy and lower limb exercises. 94 stroke survivors with upper and lower limb limitations at least 1-week post-stroke undertook 4 weeks of daily patient-led mirror therapy or lower limb exercise, then completed questionnaires regarding their experience and satisfaction. A convenience random sample of 20 participants also completed a semi-structured telephone interview to consider their experience in more detail and to capture their longer term impressions. Participants were generally positive about patient-led therapy. About 71% found it useful; 68% enjoyed it; 59% felt it "worked" and 88% would recommend it to other patients. Exercise was viewed more positively than the mirror therapy. Difficulties included arranging the equipment and their position, particularly for more severe strokes, loss of motivation and concerns about working unsupervised. Patient-led mirror therapy and lower limb exercises during in-patient rehabilitation is generally feasible and acceptable to patients but "light touch" supervision to deal with any problems, and strategies to maintain focus and motivation are needed. Implications for Rehabilitation Most stroke patients receive insufficient therapy to maximize recovery during rehabilitation. As increases in staffing are unlikely there is an imperative to find ways for patients to increase the amount of exercise and practice of functional tasks they undertake without increasing demands on staff. Patient-led therapy (also known as patient-directed therapy or independent practice), in which patients undertake exercises or functional tasks practice prescribed by a professional outside formal therapy sessions is one way of achieving this. It is widely used in community-based rehabilitation but is uncommon in hospital-based stroke care. We explored the feasibility and acceptability of two types of patient-led therapy during hospital-based stroke care; mirror therapy for the upper limb and exercises (without a mirror) for the lower limb. Here, we report patients' experiences of undertaking patient-led therapy. Patient-led mirror therapy and lower limb exercises during in-patient stroke rehabilitation is generally feasible and acceptable to patients but "light touch" supervision to deal with any problems, and strategies to maintain focus and motivation are needed.

  20. Application of boronated anti-CEA immunoliposome to tumour cell growth inhibition in in vitro boron neutron capture therapy model.

    PubMed Central

    Yanagië, H.; Tomita, T.; Kobayashi, H.; Fujii, Y.; Takahashi, T.; Hasumi, K.; Nariuchi, H.; Sekiguchi, M.

    1991-01-01

    An immunoliposome containing a 10B-compound has been examined as a selective drug delivery system in boron neutron-capture therapy. Liposomes, conjugated with monoclonal antibodies specific for carcinoembryonic antigen (CEA) were shown to bind selectively to cells bearing CEA on their surface. The immunoliposomes attached to tumour cells suppressed growth in vitro upon thermal neutron irradiation and suppression was dependent upon the concentration of the 10B-compound in the liposomes and on the density of antibody conjugated to the liposomes. The results suggest that immunoliposomes containing the 10B-compound could act as a selective and efficient carrier of 10B atoms to target tumour cells in boron neutron-capture therapy. Images Figure 1 PMID:2021537

  1. Study on a liquid-moderator-based neutron spectrometer for BNCT-Development and experimental test of the prototype spectrometer

    NASA Astrophysics Data System (ADS)

    Tamaki, S.; Sato, F.; Murata, I.

    2017-10-01

    Boron neutron capture therapy (BNCT) is known to be an effective radiation cancer therapy that requires neutron irradiation. A neutron field generated by an accelerator-based neutron source has various energy spectra, and it is necessary to evaluate the neutron spectrum in the treatment field. However, the method used to measure the neutron spectrum in the treatment field is not well established, and many researchers are making efforts to improve the spectrometers used. In the present study, we developed a prototype of a new neutron spectrometer that can measure the neutron spectra more accurately and precisely. The spectrometer is based on the same theory as that of the Bonner sphere spectrometer, and it uses a liquid moderator and an absorber. By carrying out an experimental test of the developed spectrometer, we finally revealed the problems and necessary conditions of the prototype detector.

  2. Boron neutron capture therapy as new treatment for clear cell sarcoma: trial on different animal model.

    PubMed

    Andoh, Tooru; Fujimoto, Takuya; Sudo, Tamotsu; Suzuki, Minoru; Sakurai, Yoshinori; Sakuma, Toshiko; Moritake, Hiroshi; Sugimoto, Tohru; Takeuchi, Tamotsu; Sonobe, Hiroshi; Epstein, Alan L; Fukumori, Yoshinobu; Ono, Koji; Ichikawa, Hideki

    2014-06-01

    Clear cell sarcoma (CCS) is a rare malignant tumor with a poor prognosis. In our previous study, the tumor disappeared under boron neutron capture therapy (BNCT) on subcutaneously-transplanted CCS-bearing animals. In the present study, the tumor disappeared under this therapy on model mice intramuscularly implanted with three different human CCS cells. BNCT led to the suppression of tumor-growth in each of the different model mice, suggesting its potentiality as an alternative to, or integrative option for, the treatment of CCS. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Antiretroviral therapy outcomes among HIV infected clients in Gweru City, Zimbabwe 2006 - 2011: a cohort analysis.

    PubMed

    Shambira, Gerald; Gombe, Notion Tafara; Hall, Casey Daniel; Park, Meeyoung Mattie; Frimpong, Joseph Asamoah

    2017-01-01

    The government of Zimbabwe began providing antiretroviral therapy (ART) to People Living with HIV/AIDS (PLHIV) in public institutions in 2004. In Midlands province two clinics constituted the most active HIV care service points, with patients being followed up through a comprehensive patient monitoring and tracking system which captured specific patient variables and outcomes over time. The data from 2006 to 2011 were subjected to analysis to answer specific research questions and this case study is based on that analysis. The goal of this case study is to build participants' capacity to undertake secondary data analysis and interpretation using a dataset for HIV antiretroviral therapy in Zimbabwe and to draw conclusions which inform recommendations. Case studies in applied epidemiology allow students to practice applying epidemiologic skills in the classroom to address real-world public health problems. Case studies as a vital component of an applied epidemiology curriculum are instrumental in reinforcing principles and skills covered in lectures or in background reading. The target audience includes Field Epidemiology and Laboratory Training Programs (FELTPs), university students, district health executives, and health information officers.

  4. Boronated porhyrins and methods for their use

    DOEpatents

    Miura, Michiko; Shelnutt, John A.; Slatkin, Daniel N.

    1999-03-02

    The present invention covers boronated porphyrins containing multiple carborane cages which selectively accumulate in neoplastic tissue within the irradiation volume and thus can be used in cancer therapies such as boron neutron capture therapy and photodynamic therapy.

  5. Physics of epi-thermal boron neutron capture therapy (epi-thermal BNCT).

    PubMed

    Seki, Ryoichi; Wakisaka, Yushi; Morimoto, Nami; Takashina, Masaaki; Koizumi, Masahiko; Toki, Hiroshi; Fukuda, Mitsuhiro

    2017-12-01

    The physics of epi-thermal neutrons in the human body is discussed in the effort to clarify the nature of the unique radiologic properties of boron neutron capture therapy (BNCT). This discussion leads to the computational method of Monte Carlo simulation in BNCT. The method is discussed through two examples based on model phantoms. The physics is kept at an introductory level in the discussion in this tutorial review.

  6. Are young people hospitalised with psychosis interested in psychological therapy?

    PubMed

    Mitchison, Deborah; Jakes, Simon; Kelly, Siobhan; Rhodes, John

    2015-01-01

    Psychotic clients may be difficult to engage in psychological therapy, and many potential participants decline to participate in controlled trials of cognitive behavioural therapy. The aim of this study was to investigate psychotic patients' perspectives regarding therapy. The design was qualitative and used thematic analysis to investigate emerging themes. Methods A total of 46 inpatients with psychosis were interviewed about their views on therapy. Interview summaries were submitted to thematic analysis. A total of 41% of participants were rated as interested, 36% were rated as not interested and 23% appeared ambivalent, or their interest in therapy was unable to be assessed. Themes related to interest in therapy included the desire to build skills, to address (usually non-psychotic) symptoms and for a therapeutic relationship. Themes related to not wanting therapy included a denial of psychological problems, distrust in the healthcare system and psychologists and low perceived efficacy in therapy. A large minority of psychotic patients may be interested in therapy, although mostly not to address psychotic symptoms. Future research on pre-treatment approaches to disconfirm negative perceptions and increase interest in therapy is warranted. The reasons why some patients with psychosis are not interested in receiving psychological therapy may relate to past negative experiences with psychologists, negative perceptions of psychologists as a group and low perceived efficacy of therapy. These barriers may be addressed through interactions with psychotic patients during an admission to a hospital that disconfirms these perceptions and provides a positive alternative experience with a psychologist. Patients who are hospitalized with psychosis may be interested in receiving psychological therapy; however, the reason for this likely will not be to address psychotic symptoms. Rather, the therapist should be willing to work with the patient on a range of other presenting problems. If a patient has a lack of insight into their psychotic symptoms, this does not always negate them from perceiving other psychological problems for which they may desire support in addressing. Thus, therapists should be encouraged to approach all psychotic patients on a ward, even when there is an apparent lack of awareness of their psychotic symptoms. The themes related to patients' perspectives were generated from psychologists' summaries of interviews with patients and not directly from verbatim transcripts. Although this meant that the reasons given for participants being interested or not interested in therapy were interpreted by the psychologist, efforts were made to relate the exact reasons provided by the participants. Eighteen (29%) of the potential participants were not interviewed, usually as a result of their being discharged or transferred prior to arrangement of an interview. This meant we were unable to capture the views of these patients. Discharge prior to being seen by a psychologist is a barrier to engaging a patient in therapy and preventing them falling through the gaps of service provision. Copyright © 2013 John Wiley & Sons, Ltd.

  7. Boronated porhyrins and methods for their use

    DOEpatents

    Miura, M.; Shelnutt, J.A.; Slatkin, D.N.

    1999-03-02

    The present invention covers boronated porphyrins containing multiple carborane cages which selectively accumulate in neoplastic tissue within the irradiation volume and thus can be used in cancer therapies such as boron neutron capture therapy and photodynamic therapy. 3 figs.

  8. Satellite capture as a restricted 2 + 2 body problem

    NASA Astrophysics Data System (ADS)

    Kanaan, Wafaa; Farrelly, David; Lanchares, Víctor

    2018-04-01

    A restricted 2 + 2 body problem is proposed as a possible mechanism to explain the capture of small bodies by a planet. In particular, we consider two primaries revolving in a circular mutual orbit and two small bodies of equal mass, neither of which affects the motion of the primaries. If the small bodies are temporarily captured in the Hill sphere of the smaller primary, they may get close enough to each other to exchange energy in such a way that one of them becomes permanently captured. Numerical simulations show that capture is possible for both prograde and retrograde orbits.

  9. A new electrocardiogram algorithm for diagnosing loss of ventricular capture during cardiac resynchronisation therapy.

    PubMed

    Ganière, Vincent; Domenichini, Giulia; Niculescu, Viviana; Cassagneau, Romain; Defaye, Pascal; Burri, Haran

    2013-03-01

    The prerequisite for cardiac resynchronization therapy (CRT) is ventricular capture, which may be verified by analysis of the surface electrocardiogram (ECG). Few algorithms exist to diagnose loss of ventricular capture. Electrocardiograms from 126 CRT patients were analysed during biventricular (BV), right ventricular (RV), and left ventricular (LV) pacing. An algorithm evaluating QRS narrowing in the limb leads and increasing negativity in lead I to diagnose changes in ventricular capture was devised, prospectively validated, and compared with two existing algorithms. Performance of the algorithm according to ventricular lead position was also assessed. Our algorithm had an accuracy of 88% to correctly identify the changes in ventricular capture (either loss or gain of RV or LV capture). The algorithm had a sensitivity of 94% and a specificity of 96% with an accuracy of 96% for identifying loss of LV capture (the most clinically relevant change), and compared favourably with the existing algorithms. Performance of the algorithms was not significantly affected by RV or LV lead position. A simple two-step algorithm evaluating QRS width in the limb leads and changes in negativity in lead I can accurately diagnose the lead responsible for intermittent loss of ventricular capture in CRT. This simple tool may be of particular use outside the setting of specialized device clinics.

  10. Electrostatic design and beam transport for a folded tandem electrostatic quadrupole accelerator facility for accelerator-based boron neutron capture therapy.

    PubMed

    Vento, V Thatar; Bergueiro, J; Cartelli, D; Valda, A A; Kreiner, A J

    2011-12-01

    Within the frame of an ongoing project to develop a folded Tandem-Electrostatic-Quadrupole (TESQ) accelerator facility for Accelerator-Based Boron Neutron Capture Therapy (AB-BNCT), we discuss here the electrostatic design of the machine, including the accelerator tubes with electrostatic quadrupoles and the simulations for the transport and acceleration of a high intensity beam. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. [Possibilities of boron neutron capture therapy in the treatment of malignant brain tumors].

    PubMed

    Kanygin, V V; Kichigin, A I; Gubanova, N V; Taskaev, S Yu

    2015-01-01

    Boron neutron capture therapy (BNCT) that is of the highest attractiveness due to its selective action directly on malignant tumor cells is a promising approach to treating cancers. Clinical interest in BNCT focuses in neuro-oncology on therapy for gliomas, glioblastoma in particular, and BNCT may be used in brain metastatic involvement. This needs an epithermal neutron source that complies with the requirements for BNCT, as well as a 10B-containing agent that will selectively accumulate in tumor tissue. The introduction of BNCT into clinical practice to treat patients with glial tumors will be able to enhance therapeutic efficiency.

  12. An Approach to Scoring Collaboration in Online Game Environments

    ERIC Educational Resources Information Center

    Scoular, Claire; Care, Esther; Awwal, Nafisa

    2017-01-01

    With technological advances, it is now possible to use games to capture information-rich behaviours that reveal processes by which players interact and solve problems. Recent problem-based games have been designed to assess and record detailed interactions between the problem solver and the game environment, and thereby capture salient solution…

  13. Orthogonal-blendshape-based editing system for facial motion capture data.

    PubMed

    Li, Qing; Deng, Zhigang

    2008-01-01

    The authors present a novel data-driven 3D facial motion capture data editing system using automated construction of an orthogonal blendshape face model and constrained weight propagation, aiming to bridge the popular facial motion capture technique and blendshape approach. In this work, a 3D facial-motion-capture-editing problem is transformed to a blendshape-animation-editing problem. Given a collected facial motion capture data set, we construct a truncated PCA space spanned by the greatest retained eigenvectors and a corresponding blendshape face model for each anatomical region of the human face. As such, modifying blendshape weights (PCA coefficients) is equivalent to editing their corresponding motion capture sequence. In addition, a constrained weight propagation technique allows animators to balance automation and flexible controls.

  14. Synthesis and in vitro evaluation of thiododecaborated α, α- cycloalkylamino acids for the treatment of malignant brain tumors by boron neutron capture therapy.

    PubMed

    Hattori, Yoshihide; Kusaka, Shintaro; Mukumoto, Mari; Ishimura, Miki; Ohta, Yoichiro; Takenaka, Hiroshi; Uehara, Kouki; Asano, Tomoyuki; Suzuki, Minoru; Masunaga, Shin-Ichiro; Ono, Koji; Tanimori, Shinji; Kirihata, Mitsunori

    2014-12-01

    Boron-neutron capture therapy (BNCT) is an attractive technique for cancer treatment. As such, α, α-cycloalkyl amino acids containing thiododecaborate ([B12H11](2-)-S-) units were designed and synthesized as novel boron delivery agents for BNCT. In the present study, new thiododecaborate α, α-cycloalkyl amino acids were synthesized, and biological evaluation of the boron compounds as boron carrier for BNCT was carried out.

  15. Boron neutron capture therapy for oral precancer: proof of principle in an experimental animal model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A. Monti Hughes; ECC Pozzi; S. Thorp

    Field-cancerized tissue can give rise to second primary tumours, causing therapeutic failure. Boron neutron capture therapy (BNCT) is based on biological targeting and would serve to treat undetectable foci of malignant transformation. The aim of this study was to optimize BNCT for the integral treatment for oral cancer, with particular emphasis on the inhibitory effect on tumour development originating in precancerous conditions, and radiotoxicity of different BNCT protocols in a hamster cheek pouch oral precancer model.

  16. Towards boron neutron capture therapy: the formulation and preliminary in vitro evaluation of liposomal vehicles for the therapeutic delivery of the dequalinium salt of bis-nido-carborane.

    PubMed

    Theodoropoulos, Dimitrios; Rova, Aikaterini; Smith, James R; Barbu, Eugen; Calabrese, Gianpiero; Vizirianakis, Ioannis S; Tsibouklis, John; Fatouros, Dimitrios G

    2013-11-15

    Liposomes of phosphatidylcholine or of dimyristoylphosphatidylcholine that incorporate bis-nido-carborane dequalinium salt are stable in physiologically relevant media and have in vitro toxicity profiles that appear to be compatible with potential therapeutic applications. These features render the structures suitable candidate boron-delivery vehicles for evaluation in the boron neutron capture therapy of cancer. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Intracellular delivery and passive tumor targeting of a self-assembled nanogel containing carborane clusters for boron neutron capture therapy.

    PubMed

    Kawasaki, Riku; Sasaki, Yoshihiro; Akiyoshi, Kazunari

    2017-01-29

    Boron neutron capture therapy, based on the release of thermal neutron irradiation from boron, is a targeted radiation therapy for cancer. Targeted and sufficient accumulation of boron in tumor cells to achieve cytotoxic efficacy and reduce off-target effects remains a challenge. Carborane has been investigated for use as a delivery agent in boron neutron capture therapy because of its high boron content and chemical stability; however, it is cytotoxic, making safe delivery difficult. The aim of this study was to investigate the potential of carborane-bearing pullulan nanogels to safely and effectively deliver boron to tumor cells in vitro and in vivo and, consequently, assess their potential as a boron neutron capture therapeutic. Murine fibrosarcoma cells (CMS5a) were used for in vitro investigations of nanogel cytotoxicity, cell uptake. A mouse fibrosarcoma xenograft model was used to investigate the bio-distribution of nanogels after intravenous administration. The nanogels produced no apparent cytotoxicity and underwent cell uptake in CMS5a cells after a 24 h incubation at up to 2000 μg/mL and 400 μg/mL, respectively. The internalized nanogels were localized around the nuclear membrane. The nanogels were administered intravenously to mice bearing fibrosarcoma xenografts. Nanogel tumor localization likely occurred through the enhanced permeation and retention effect. The nanogels successfully reduced the cytotoxicity of carborane, were internalized into tumor cells, acted as a dual-delivery therapeutic and accumulated in tumors in vivo. Consequently, they demonstrate significant potential as a boron neutron capture therapeutic. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Improving the image discontinuous problem by using color temperature mapping method

    NASA Astrophysics Data System (ADS)

    Jeng, Wei-De; Mang, Ou-Yang; Lai, Chien-Cheng; Wu, Hsien-Ming

    2011-09-01

    This article mainly focuses on image processing of radial imaging capsule endoscope (RICE). First, it used the radial imaging capsule endoscope (RICE) to take the images, the experimental used a piggy to get the intestines and captured the images, but the images captured by RICE were blurred due to the RICE has aberration problems in the image center and lower light uniformity affect the image quality. To solve the problems, image processing can use to improve it. Therefore, the images captured by different time can use Person correlation coefficient algorithm to connect all the images, and using the color temperature mapping way to improve the discontinuous problem in the connection region.

  19. Design of a boron neutron capture enhanced fast neutron therapy assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Zhonglu

    The use of boron neutron capture to boost tumor dose in fast neutron therapy has been investigated at several fast neutron therapy centers worldwide. This treatment is termed boron neutron capture enhanced fast neutron therapy (BNCEFNT). It is a combination of boron neutron capture therapy (BNCT) and fast neutron therapy (FNT). It is believed that BNCEFNT may be useful in the treatment of some radioresistant brain tumors, such as glioblastoma multiform (GBM). A boron neutron capture enhanced fast neutron therapy assembly has been designed for the Fermilab Neutron Therapy Facility (NTF). This assembly uses a tungsten filter and collimator nearmore » the patient's head, with a graphite reflector surrounding the head to significantly increase the dose due to boron neutron capture reactions. The assembly was designed using Monte Carlo radiation transport code MCNP version 5 for a standard 20x20 cm 2 treatment beam. The calculated boron dose enhancement at 5.7-cm depth in a water-filled head phantom in the assembly with a 5x5 cm 2 collimation was 21.9% per 100-ppm 10B for a 5.0-cm tungsten filter and 29.8% for a 8.5-cm tungsten filter. The corresponding dose rate for the 5.0-cm and 8.5-cm thick filters were 0.221 and 0.127 Gy/min, respectively; about 48.5% and 27.9% of the dose rate of the standard 10x10 cm 2 fast neutron treatment beam. To validate the design calculations, a simplified BNCEFNT assembly was built using four lead bricks to form a 5x5 cm 2 collimator. Five 1.0-cm thick 20x20 cm 2 tungsten plates were used to obtain different filter thicknesses and graphite bricks/blocks were used to form a reflector. Measurements of the dose enhancement of the simplified assembly in a water-filled head phantom were performed using a pair of tissue-equivalent ion chambers. One of the ion chambers is loaded with 1000-ppm natural boron (184-ppm 10B) to measure dose due to boron neutron capture. The measured dose enhancement at 5.0-cm depth in the head phantom for the 5.0-cm thick tungsten filter is (16.6 ± 1.8)%, which agrees well with the MCNP simulation of the simplified BNCEFNT assembly, (16.4 ± 0.5)%. The error in the calculated dose enhancement only considers the statistical uncertainties. The total dose rate measured at 5.0-cm depth using the non-borated ion chamber is (0.765 ± 0.076) Gy/MU, about 61% of the fast neutron standard dose rate (1.255Gy/MU) at 5.0-cm depth for the standard 10x10 cm 2 treatment beam. The increased doses to other organs due to the use of the BNCEFNT assembly were calculated using MCNP5 and a MIRD phantom. The activities of the activation products produced in the BNCEFNT assembly after neutron beam delivery were computed. The photon ambient dose rate due to the radioactive activation products was also estimated.« less

  20. The Role of Day-to-Day Emotions, Sleep, and Social Interactions in Pediatric Anxiety Treatment

    PubMed Central

    Wallace, Meredith L.; McMakin, Dana L.; Tan, Patricia Z.; Rosen, Dana; Forbes, Erika E.; Ladouceur, Cecile D.; Ryan, Neal D.; Siegle, Greg J.; Dahl, Ronald E.; Kendall, Philip C.; Mannarino, Anthony; Silk, Jennifer S.

    2016-01-01

    Do day-to-day emotions, social interactions, and sleep play a role in determining which anxious youth respond to supportive child-centered therapy (CCT) versus cognitive behavioral therapy (CBT)? We explored whether measures of day-to-day functioning (captured through ecological momentary assessment, sleep diary, and actigraphy), along with clinical and demographic measures, were predictors or moderators of treatment outcome in 114 anxious youth randomized to CCT or CBT. We statistically combined individual moderators into a single, optimal composite moderator to characterize subgroups for which CCT or CBT may be preferable. The strongest predictors of better outcome included: (a) experiencing higher positive affect when with one’s mother and (b) fewer self-reported problems with sleep duration. The composite moderator indicated that youth for whom CBT was indicated had: (a) more day-to-day sleep problems related to sleep quality, efficiency, and waking, (b) day-to-day negative events related to interpersonal concerns, (c) more DSM-IV anxiety diagnoses, and (d) college-educated parents. These findings illustrate the value of both day-to-day functioning characteristics and more traditional sociodemographic and clinical characteristics in identifying optimal anxiety treatment assignment. Future studies will need to enhance the practicality of real-time measures for use in clinical decision making and evaluate additional anxiety treatments. PMID:28013054

  1. Multinational Prospective Study of Patient-Reported Outcomes After Prostate Radiation Therapy: Detailed Assessment of Rectal Bleeding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Jae Y.; Daignault-Newton, Stephanie; Heath, Gerard

    Purpose: The new short Expanded Prostate Cancer Index Composite for Clinical Practice (EPIC-CP) patient-reported health-related quality of life (HRQOL) tool has removed the rectal bleeding question from the previous much longer version, EPIC-26. Herein, we assess the impact of losing the dedicated rectal bleeding question in 2 independent prospective multicenter cohorts. Methods and Materials: In a prospective multicenter test cohort (n=865), EPIC-26 patient-reported HRQOL data were collected for 2 years after treatment from patients treated with prostate radiation therapy from 2003 to 2011. A second prospective multicenter cohort (n=442) was used for independent validation. A repeated-effects model was used to predictmore » the change from baseline in bowel summary scores from longer EPIC instruments using the change in EPIC-CP bowel summary scores with and without rectal bleeding scores. Results: Two years after radiation therapy, 91% of patients were free of bleeding, and only 2.6% reported bothersome bleeding problems. Correlations between EPIC-26 and EPIC-CP bowel scores were very high (r{sup 2}=0.90-0.96) and were statistically improved with the addition of rectal bleeding information (r{sup 2}=0.94-0.98). Considering all patients, only 0.2% of patients in the test cohort and 0.7% in the validation cohort reported bothersome bleeding and had clinically relevant HRQOL changes missed with EPIC-CP. However, of the 2.6% (n=17) of men with bothersome rectal bleeding in the test cohort, EPIC-CP failed to capture 1 patient (6%) as experiencing meaningful declines in bowel HRQOL. Conclusions: Modern prostate radiation therapy results in exceptionally low rates of bothersome rectal bleeding, and <1% of patients experience bothersome bleeding and are not captured by EPIC-CP as having meaningful HRQOL declines after radiation therapy. However, in the small subset of patients with bothersome rectal bleeding, the longer EPIC-26 should strongly be considered, given its superior performance in this patient subset.« less

  2. Hierarchical calibration and validation of computational fluid dynamics models for solid sorbent-based carbon capture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lai, Canhai; Xu, Zhijie; Pan, Wenxiao

    2016-01-01

    To quantify the predictive confidence of a solid sorbent-based carbon capture design, a hierarchical validation methodology—consisting of basic unit problems with increasing physical complexity coupled with filtered model-based geometric upscaling has been developed and implemented. This paper describes the computational fluid dynamics (CFD) multi-phase reactive flow simulations and the associated data flows among different unit problems performed within the said hierarchical validation approach. The bench-top experiments used in this calibration and validation effort were carefully designed to follow the desired simple-to-complex unit problem hierarchy, with corresponding data acquisition to support model parameters calibrations at each unit problem level. A Bayesianmore » calibration procedure is employed and the posterior model parameter distributions obtained at one unit-problem level are used as prior distributions for the same parameters in the next-tier simulations. Overall, the results have demonstrated that the multiphase reactive flow models within MFIX can be used to capture the bed pressure, temperature, CO2 capture capacity, and kinetics with quantitative accuracy. The CFD modeling methodology and associated uncertainty quantification techniques presented herein offer a solid framework for estimating the predictive confidence in the virtual scale up of a larger carbon capture device.« less

  3. Discrepancies in Autonomy and Relatedness Promoting Behaviors of Substance Using Mothers and Their Children: The Effects of a Family Systems Intervention.

    PubMed

    Zhang, Jing; Slesnick, Natasha

    2017-03-01

    Parents' and children's autonomy and relatedness behaviors are associated with a wide range of child outcomes. Yet, little is known about how parents and children's autonomy and relatedness behaviors jointly influence child outcomes. The current study captured this joint influence by exploring the longitudinal trajectory of mother-child discrepancies in autonomy and relatedness behaviors and its association with child problem behaviors. The effects of a family systems intervention on the trajectory of mother-child discrepancies were also examined. The sample included 183 substance using mothers and their children (M age = 11.54 years, SD = 2.55, range 8-16; 48 % females). Both the mother and child completed an assessment at baseline, 6- and 18-month post-baseline. A person-centered analysis identified subgroups varying in mother-child discrepancy patterns in their autonomy and relatedness behaviors. The results also showed that participation in the family systems therapy was associated with decreased mother-child discrepancies, and also a synchronous increase in mother's and child's autonomy and relatedness. Additionally, increased mother-child discrepancies and mother-child dyads showing no change in autonomy and relatedness was associated with higher levels of children's problem behaviors. The findings reveal a dynamic process of mother-child discrepancies in autonomy and relatedness behaviors related to child outcomes. The findings also support the effectiveness of the family systems therapy, and highlight the importance of understanding the complexities in family interactions when explaining children's problem behaviors.

  4. Optimal ballistically captured Earth-Moon transfers

    NASA Astrophysics Data System (ADS)

    Ricord Griesemer, Paul; Ocampo, Cesar; Cooley, D. S.

    2012-07-01

    The optimality of a low-energy Earth-Moon transfer terminating in ballistic capture is examined for the first time using primer vector theory. An optimal control problem is formed with the following free variables: the location, time, and magnitude of the transfer insertion burn, and the transfer time. A constraint is placed on the initial state of the spacecraft to bind it to a given initial orbit around a first body, and on the final state of the spacecraft to limit its Keplerian energy with respect to a second body. Optimal transfers in the system are shown to meet certain conditions placed on the primer vector and its time derivative. A two point boundary value problem containing these necessary conditions is created for use in targeting optimal transfers. The two point boundary value problem is then applied to the ballistic lunar capture problem, and an optimal trajectory is shown. Additionally, the problem is then modified to fix the time of transfer, allowing for optimal multi-impulse transfers. The tradeoff between transfer time and fuel cost is shown for Earth-Moon ballistic lunar capture transfers.

  5. A critical assessment of boron target compounds for boron neutron capture therapy.

    PubMed

    Hawthorne, M Frederick; Lee, Mark W

    2003-01-01

    Boron neutron capture therapy (BNCT) has undergone dramatic developments since its inception by Locher in 1936 and the development of nuclear energy during World War II. The ensuing Cold War spawned the entirely new field of polyhedral borane chemistry, rapid advances in nuclear reactor technology and a corresponding increase in the number to reactors potentially available for BNCT. This effort has been largely oriented toward the eradication of glioblastoma multiforme (GBM) and melanoma with reduced interest in other types of malignancies. The design and synthesis of boron-10 target compounds needed for BNCT was not channeled to those types of compounds specifically required for GBM or melanoma. Consequently, a number of potentially useful boron agents are known which have not been biologically evaluated beyond a cursory examination and only three boron-10 enriched target species are approved for human use following their Investigational New Drug classification by the US Food and Drug Administration; BSH, BPA and GB-10. All ongoing clinical trials with GBM and melanoma are necessarily conducted with one of these three species and most often with BPA. The further development of BNCT is presently stalled by the absence of strong support for advanced compound evaluation and compound discovery driven by recent advances in biology and chemistry. A rigorous demonstration of BNCT efficacy surpassing that of currently available protocols has yet to be achieved. This article discusses the past history of compound development, contemporary problems such as compound classification and those problems which impede future advances. The latter include means for biological evaluation of new (and existing) boron target candidates at all stages of their development and the large-scale synthesis of boron target species for clinical trials and beyond. The future of BNCT is bright if latitude is given to the choice of clinical disease to be treated and if a recognized study demonstrating improved efficacy is completed. Eventually, BNCT in some form will be commercialized.

  6. Boron Neutron Capture Therapy in the Treatment of Recurrent Laryngeal Cancer.

    PubMed

    Haapaniemi, Aaro; Kankaanranta, Leena; Saat, Riste; Koivunoro, Hanna; Saarilahti, Kauko; Mäkitie, Antti; Atula, Timo; Joensuu, Heikki

    2016-05-01

    To investigate the safety and efficacy of boron neutron capture therapy (BNCT) as a larynx-preserving treatment option for patients with recurrent laryngeal cancer. Six patients with locally recurrent squamous cell laryngeal carcinoma and 3 patients with persistent laryngeal cancer after prior treatment were treated with BNCT at the FiR1 facility (Espoo, Finland) in 2006 to 2012. The patients had received prior radiation therapy with or without concomitant chemotherapy to a cumulative median dose of 66 Gy. The median tumor diameter was 2.9 cm (range, 1.4-10.9 cm) before BNCT. Boron neutron capture therapy was offered on a compassionate basis to patients who either refused laryngectomy (n=7) or had an inoperable tumor (n=2). Boronophenylalanine-fructose (400 mg/kg) was used as the boron carrier and was infused over 2 hours intravenously before neutron irradiation. Six patients received BNCT once and 3 twice. The estimated average gross tumor volume dose ranged from 22 to 38 Gy (W) (mean; 29 Gy [W]). Six of the 8 evaluable patients responded to BNCT; 2 achieved complete and 4 partial response. One patient died early and was not evaluable for response. Most common side effects were stomatitis, fatigue, and oral pain. No life-threatening or grade 4 toxicity was observed. The median time to progression within the target volume was 6.6 months, and the median overall survival time 13.3 months after BNCT. One patient with complete response is alive and disease-free with a functioning larynx 60 months after BNCT. Boron neutron capture therapy given after prior external beam radiation therapy is well tolerated. Most patients responded to BNCT, but long-term survival with larynx preservation was infrequent owing to cancer progression. Selected patients with recurrent laryngeal cancer may benefit from BNCT. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Boron Neutron Capture Therapy in the Treatment of Recurrent Laryngeal Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haapaniemi, Aaro, E-mail: aaro.haapaniemi@hus.fi; Kankaanranta, Leena; Saat, Riste

    2016-05-01

    Purpose: To investigate the safety and efficacy of boron neutron capture therapy (BNCT) as a larynx-preserving treatment option for patients with recurrent laryngeal cancer. Methods and Materials: Six patients with locally recurrent squamous cell laryngeal carcinoma and 3 patients with persistent laryngeal cancer after prior treatment were treated with BNCT at the FiR1 facility (Espoo, Finland) in 2006 to 2012. The patients had received prior radiation therapy with or without concomitant chemotherapy to a cumulative median dose of 66 Gy. The median tumor diameter was 2.9 cm (range, 1.4-10.9 cm) before BNCT. Boron neutron capture therapy was offered on a compassionate basis to patientsmore » who either refused laryngectomy (n=7) or had an inoperable tumor (n=2). Boronophenylalanine-fructose (400 mg/kg) was used as the boron carrier and was infused over 2 hours intravenously before neutron irradiation. Results: Six patients received BNCT once and 3 twice. The estimated average gross tumor volume dose ranged from 22 to 38 Gy (W) (mean; 29 Gy [W]). Six of the 8 evaluable patients responded to BNCT; 2 achieved complete and 4 partial response. One patient died early and was not evaluable for response. Most common side effects were stomatitis, fatigue, and oral pain. No life-threatening or grade 4 toxicity was observed. The median time to progression within the target volume was 6.6 months, and the median overall survival time 13.3 months after BNCT. One patient with complete response is alive and disease-free with a functioning larynx 60 months after BNCT. Conclusions: Boron neutron capture therapy given after prior external beam radiation therapy is well tolerated. Most patients responded to BNCT, but long-term survival with larynx preservation was infrequent owing to cancer progression. Selected patients with recurrent laryngeal cancer may benefit from BNCT.« less

  8. Health Problems Discovery from Motion-Capture Data of Elderly

    NASA Astrophysics Data System (ADS)

    Pogorelc, B.; Gams, M.

    Rapid aging of the population of the developed countries could exceed the society's capacity for taking care for them. In order to help solving this problem, we propose a system for automatic discovery of health problems from motion-capture data of gait of elderly. The gait of the user is captured with the motion capture system, which consists of tags attached to the body and sensors situated in the apartment. Position of the tags is acquired by the sensors and the resulting time series of position coordinates are analyzed with machine learning algorithms in order to identify the specific health problem. We propose novel features for training a machine learning classifier that classifies the user's gait into: i) normal, ii) with hemiplegia, iii) with Parkinson's disease, iv) with pain in the back and v) with pain in the leg. Results show that naive Bayes needs more tags and less noise to reach classification accuracy of 98 % than support vector machines for 99 %.

  9. Tandem-ESQ for Accelerator-Based Boron Neutron Capture Therapy (AB-BNCT)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kreiner, A. J.; Escuela de Ciencia y Tecnologia, Universidad de Gral San Martin; CONICET,

    2007-02-12

    A folded tandem, with 1.25 MV terminal voltage, combined with an ElectroStatic Quadrupole (ESQ) chain is being proposed as a machine for Accelerator-Based Boron Neutron Capture Therapy (AB-BNCT). The machine is shown to be capable of accelerating a 30 mA proton beam to 2.5 MeV. These are the specifications needed to produce sufficiently intense and clean epithermal neutron beams, based on the on the 7Li(p,n)7Be reaction, to perform BNCT treatment for deep seated tumors in less than an hour.

  10. Clinical trials of boron neutron capture therapy [in humans] [at Beth Israel Deaconess Medical Center][at Brookhaven National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wallace, Christine

    2001-05-29

    Assessment of research records of Boron Neutron Capture Therapy was conducted at Brookhaven National Laboratory and Beth Israel Deaconess Medical Center using the Code of Federal Regulations, FDA Regulations and Good Clinical Practice Guidelines. Clinical data were collected from subjects' research charts, and differences in conduct of studies at both centers were examined. Records maintained at Brookhaven National Laboratory were not in compliance with regulatory standards. Beth Israel's records followed federal regulations. Deficiencies discovered at both sites are discussed in the reports.

  11. Metrics for Performance Evaluation of Patient Exercises during Physical Therapy.

    PubMed

    Vakanski, Aleksandar; Ferguson, Jake M; Lee, Stephen

    2017-06-01

    The article proposes a set of metrics for evaluation of patient performance in physical therapy exercises. Taxonomy is employed that classifies the metrics into quantitative and qualitative categories, based on the level of abstraction of the captured motion sequences. Further, the quantitative metrics are classified into model-less and model-based metrics, in reference to whether the evaluation employs the raw measurements of patient performed motions, or whether the evaluation is based on a mathematical model of the motions. The reviewed metrics include root-mean square distance, Kullback Leibler divergence, log-likelihood, heuristic consistency, Fugl-Meyer Assessment, and similar. The metrics are evaluated for a set of five human motions captured with a Kinect sensor. The metrics can potentially be integrated into a system that employs machine learning for modelling and assessment of the consistency of patient performance in home-based therapy setting. Automated performance evaluation can overcome the inherent subjectivity in human performed therapy assessment, and it can increase the adherence to prescribed therapy plans, and reduce healthcare costs.

  12. White Paper: Movement System Diagnoses in Neurologic Physical Therapy.

    PubMed

    Hedman, Lois D; Quinn, Lori; Gill-Body, Kathleen; Brown, David A; Quiben, Myla; Riley, Nora; Scheets, Patricia L

    2018-04-01

    The APTA recently established a vision for physical therapists to transform society by optimizing movement to promote health and wellness, mitigate impairments, and prevent disability. An important element of this vision entails the integration of the movement system into the profession, and necessitates the development of movement system diagnoses by physical therapists. At this point in time, the profession as a whole has not agreed upon diagnostic classifications or guidelines to assist in developing movement system diagnoses that will consistently capture an individual's movement problems. We propose that, going forward, diagnostic classifications of movement system problems need to be developed, tested, and validated. The Academy of Neurologic Physical Therapy's Movement System Task Force was convened to address these issues with respect to management of movement system problems in patients with neurologic conditions. The purpose of this article is to report on the work and recommendations of the Task Force. The Task Force identified 4 essential elements necessary to develop and implement movement system diagnoses for patients with primarily neurologic involvement from existing movement system classifications. The Task Force considered the potential impact of using movement system diagnoses on clinical practice, education and, research. Recommendations were developed and provided recommendations for potential next steps to broaden this discussion and foster the development of movement system diagnostic classifications. The Task Force proposes that diagnostic classifications of movement system problems need to be developed, tested, and validated with the long-range goal to reach consensus on and adoption of a movement system diagnostic framework for clients with neurologic injury or disease states.Video Abstract available for more insights from the authors (see Video, Supplemental Digital Content 1, available at: http://links.lww.com/JNPT/A198).

  13. Family Therapy Training at the Ackerman Institute: Thoughts of Form and Substance.

    ERIC Educational Resources Information Center

    LaPerriere, Kitty

    1979-01-01

    Presents the history, philosophy, and form of training at the Ackerman Institute for Family Therapy, and attempts to capture the spirit and atmosphere of the program rather than enumerate details. The program teaches family therapy and a systems perspective on human behavior to professionals who have completed basic professional training. (Author)

  14. System and method for delivery of neutron beams for medical therapy

    DOEpatents

    Nigg, David W.; Wemple, Charles A.

    1999-01-01

    A neutron delivery system that provides improved capability for tumor control during medical therapy. The system creates a unique neutron beam that has a bimodal or multi-modal energy spectrum. This unique neutron beam can be used for fast-neutron therapy, boron neutron capture therapy (BNCT), or both. The invention includes both an apparatus and a method for accomplishing the purposes of the invention.

  15. Cyclic-RGDyC functionalized liposomes for dual-targeting of tumor vasculature and cancer cells in glioblastoma: An in vitro boron neutron capture therapy study.

    PubMed

    Kang, Weirong; Svirskis, Darren; Sarojini, Vijayalekshmi; McGregor, Ailsa L; Bevitt, Joseph; Wu, Zimei

    2017-05-30

    The efficacy of boron neutron capture therapy depends on the selective delivery of 10B to the target. Integrins αvβ3 are transmembrane receptors over-expressed in both glioblastoma cells and its neovasculature. In this study, a novel approach to dual-target glioblastoma vasculature and tumor cells was investigated. Liposomes (124 nm) were conjugated with a αvβ3 ligand, cyclic arginine-glycine-aspartic acid-tyrosine-cysteine peptide (c(RGDyC)-LP) (1% molar ratio) through thiol-maleimide coupling. Expression of αvβ3 in glioblastoma cells (U87) and human umbilical vein endothelial cells (HUVEC), representing tumor angiogenesis, was determined using Western Blotting with other cells as references. The results showed that both U87 and HUVEC had stronger expression of αvβ3 than other cell types, and the degree of cellular uptake of c(RGDyC)-LP correlated with the αvβ3-expression levels of the cells. In contrast, control liposomes without c(RGDyC) showed little cellular uptake, regardless of cell type. In an in vitro boron neutron capture therapy study, the c(RGDyC)-LP containing sodium borocaptate generated more rapid and significant lethal effects to both U87 and HUVEC than the control liposomes and drug solution. Interestingly, neutron irradiated U87 and HUVEC showed different types of subsequent cell death. In conclusion, this study has demonstrated the potential of a new dual-targeting strategy using c(RGDyC)-LP to improve boron neutron capture therapy for glioblastoma.

  16. Cyclic-RGDyC functionalized liposomes for dual-targeting of tumor vasculature and cancer cells in glioblastoma: An in vitro boron neutron capture therapy study

    PubMed Central

    Kang, Weirong; Svirskis, Darren; Sarojini, Vijayalekshmi; McGregor, Ailsa L.; Bevitt, Joseph; Wu, Zimei

    2017-01-01

    The efficacy of boron neutron capture therapy depends on the selective delivery of 10B to the target. Integrins αvβ3 are transmembrane receptors over-expressed in both glioblastoma cells and its neovasculature. In this study, a novel approach to dual-target glioblastoma vasculature and tumor cells was investigated. Liposomes (124 nm) were conjugated with a αvβ3 ligand, cyclic arginine-glycine-aspartic acid-tyrosine-cysteine peptide (c(RGDyC)-LP) (1% molar ratio) through thiol-maleimide coupling. Expression of αvβ3 in glioblastoma cells (U87) and human umbilical vein endothelial cells (HUVEC), representing tumor angiogenesis, was determined using Western Blotting with other cells as references. The results showed that both U87 and HUVEC had stronger expression of αvβ3 than other cell types, and the degree of cellular uptake of c(RGDyC)-LP correlated with the αvβ3-expression levels of the cells. In contrast, control liposomes without c(RGDyC) showed little cellular uptake, regardless of cell type. In an in vitro boron neutron capture therapy study, the c(RGDyC)-LP containing sodium borocaptate generated more rapid and significant lethal effects to both U87 and HUVEC than the control liposomes and drug solution. Interestingly, neutron irradiated U87 and HUVEC showed different types of subsequent cell death. In conclusion, this study has demonstrated the potential of a new dual-targeting strategy using c(RGDyC)-LP to improve boron neutron capture therapy for glioblastoma. PMID:28402271

  17. Boron neutron capture therapy: Moving toward targeted cancer therapy.

    PubMed

    Mirzaei, Hamid Reza; Sahebkar, Amirhossein; Salehi, Rasoul; Nahand, Javid Sadri; Karimi, Ehsan; Jaafari, Mahmoud Reza; Mirzaei, Hamed

    2016-01-01

    Boron neutron capture therapy (BNCT) occurs when a stable isotope, boton-10, is irradiated with low-energy thermal neutrons to yield stripped down helium-4 nuclei and lithium-7 nuclei. It is a binary therapy in the treatment of cancer in which a cytotoxic event is triggered when an atom placed in a cancer cell. Here, we provide an overview on the application of BNCT in cancer therapy as well as current preclinical and clinical evidence on the efficacy of BNCT in the treatment of melanoma, brain tumors, head and neck cancer, and thyroid cancer. Several studies have shown that BNCT is effective in patients who had been treated with a full dose of conventional radiotherapy, because of its selectivity. In addition, BNCT is dependent on the normal/tumor tissue ratio of boron distribution. Increasing evidence has shown that BNCT can be combined with different drug delivery systems to enhance the delivery of boron to cancer cells. The flexibility of BNCT to be used in combination with different tumor-targeting approaches has made this strategy a promising option for cancer therapy. This review aims to provide a state-of-the-art overview of the recent advances in the use of BNCT for targeted therapy of cancer.

  18. Boron neutron capture therapy of malignant brain tumors at the Brookhaven Medical Research Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joel, D.D.; Coderre, J.A.; Chanana, A.D.

    1996-12-31

    Boron neutron capture therapy (BNCT) is a bimodal form of radiation therapy for cancer. The first component of this treatment is the preferential localization of the stable isotope {sup 10}B in tumor cells by targeting with boronated compounds. The tumor and surrounding tissue is then irradiated with a neutron beam resulting in thermal neutron/{sup 10}B reactions ({sup 10}B(n,{alpha}){sup 7}Li) resulting in the production of localized high LET radiation from alpha and {sup 7}Li particles. These products of the neutron capture reaction are very damaging to cells, but of short range so that the majority of the ionizing energy released ismore » microscopically confined to the vicinity of the boron-containing compound. In principal it should be possible with BNCT to selectively destroy small nests or even single cancer cells located within normal tissue. It follows that the major improvements in this form of radiation therapy are going to come largely from the development of boron compounds with greater tumor selectivity, although there will certainly be advances made in neutron beam quality as well as the possible development of alternative sources of neutron beams, particularly accelerator-based epithermal neutron beams.« less

  19. Intracellular delivery and passive tumor targeting of a self-assembled nanogel containing carborane clusters for boron neutron capture therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kawasaki, Riku; JST-ERATO, Japan Science and Technology Agency; Sasaki, Yoshihiro

    Boron neutron capture therapy, based on the release of thermal neutron irradiation from boron, is a targeted radiation therapy for cancer. Targeted and sufficient accumulation of boron in tumor cells to achieve cytotoxic efficacy and reduce off-target effects remains a challenge. Carborane has been investigated for use as a delivery agent in boron neutron capture therapy because of its high boron content and chemical stability; however, it is cytotoxic, making safe delivery difficult. The aim of this study was to investigate the potential of carborane-bearing pullulan nanogels to safely and effectively deliver boron to tumor cells in vitro and in vivo and,more » consequently, assess their potential as a boron neutron capture therapeutic. Murine fibrosarcoma cells (CMS5a) were used for in vitro investigations of nanogel cytotoxicity, cell uptake. A mouse fibrosarcoma xenograft model was used to investigate the bio-distribution of nanogels after intravenous administration. The nanogels produced no apparent cytotoxicity and underwent cell uptake in CMS5a cells after a 24 h incubation at up to 2000 μg/mL and 400 μg/mL, respectively. The internalized nanogels were localized around the nuclear membrane. The nanogels were administered intravenously to mice bearing fibrosarcoma xenografts. Nanogel tumor localization likely occurred through the enhanced permeation and retention effect. The nanogels successfully reduced the cytotoxicity of carborane, were internalized into tumor cells, acted as a dual-delivery therapeutic and accumulated in tumors in vivo. Consequently, they demonstrate significant potential as a boron neutron capture therapeutic. - Highlights: • A carborane-bearing pullulan nanogel is developed as a boron delivery agent. • The nanogels are cell-friendly and show effective cell uptake for drug delivery. • The nanogels show passive tumor targeting by enhanced permeation and retention.« less

  20. Estimation of sex-specific survival from capture-recapture data when sex is not always known

    USGS Publications Warehouse

    Nichols, J.D.; Kendall, W.L.; Hines, J.E.; Spendelow, J.A.

    2004-01-01

    Many animals lack obvious sexual dimorphism, making assignment of sex difficult even for observed or captured animals. For many such species it is possible to assign sex with certainty only at some occasions; for example, when they exhibit certain types of behavior. A common approach to handling this situation in capture-recapture studies has been to group capture histories into those of animals eventually identified as male and female and those for which sex was never known. Because group membership is dependent on the number of occasions at which an animal was caught or observed (known sex animals, on average, will have been observed at more occasions than unknown-sex animals), survival estimates for known-sex animals will be positively biased, and those for unknown animals will be negatively biased. In this paper, we develop capture-recapture models that incorporate sex ratio and sex assignment parameters that permit unbiased estimation in the face of this sampling problem. We demonstrate the magnitude of bias in the traditional capture-recapture approach to this sampling problem, and we explore properties of estimators from other ad hoc approaches. The model is then applied to capture-recapture data for adult Roseate Terns (Sterna dougallii) at Falkner Island, Connecticut, 1993-2002. Sex ratio among adults in this population favors females, and we tested the hypothesis that this population showed sex-specific differences in adult survival. Evidence was provided for higher survival of adult females than males, as predicted. We recommend use of this modeling approach for future capture-recapture studies in which sex cannot always be assigned to captured or observed animals. We also place this problem in the more general context of uncertainty in state classification in multistate capture-recapture models.

  1. Metalloporphyrins and their uses as radiosensitizers for radiation therapy

    DOEpatents

    Miura, Michiko; Slatkin, Daniel N.

    2004-07-06

    The present invention covers radiosensitizers containing as an active ingredient halogenated derivatives of boronated porphyrins containing multiple carborane cages having the structure ##STR1## which selectively accumulate in neoplastic tissue within the irradiation volume and thus can be used in cancer therapies including, but not limited to, boron neutron--capture therapy and photodynamic therapy. The present invention also covers methods for using these radiosensitizers in tumor imaging and cancer treatment.

  2. System and method for delivery of neutron beams for medical therapy

    DOEpatents

    Nigg, D.W.; Wemple, C.A.

    1999-07-06

    A neutron delivery system that provides improved capability for tumor control during medical therapy is disclosed. The system creates a unique neutron beam that has a bimodal or multi-modal energy spectrum. This unique neutron beam can be used for fast-neutron therapy, boron neutron capture therapy (BNCT), or both. The invention includes both an apparatus and a method for accomplishing the purposes of the invention. 5 figs.

  3. Potential of boron neutron capture therapy (BNCT) for malignant peripheral nerve sheath tumors (MPNST).

    PubMed

    Fujimoto, Takuya; Andoh, Tooru; Sudo, Tamotsu; Fujita, Ikuo; Fukase, Naomasa; Takeuchi, Tamotsu; Sonobe, Hiroshi; Inoue, Masayoshi; Hirose, Tkanori; Sakuma, Toshiko; Moritake, Hiroshi; Sugimoto, Tohru; Kawamoto, Teruya; Fukumori, Yoshinobu; Yamamoto, Satomi; Atagi, Shinji; Sakurai, Yoshinori; Kurosaka, Masahiro; Ono, Koji; Ichikawa, Hideki; Suzuki, Minoru

    2015-12-01

    Malignant peripheral nerve sheath tumors (MPNST) are relatively rare neoplasms with poor prognosis. At present there is no effective treatment for MPNST other than surgical resection. Nonetheless, the anti-tumor effect of boron neutron capture therapy (BNCT) was recently demonstrated in two patients with MPNST. Subsequently, tumor-bearing nude mice subcutaneously transplanted with a human MPNST cell line were injected with p-borono-L-phenylalanine (L-BPA) and subjected to BNCT. Pathological studies then revealed that the MPNST cells were selectively destroyed by BNCT. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Correlation between radiation dose and histopathological findings in patients with gliblastoma treated with boron neutron capture therapy (BNCT).

    PubMed

    Kageji, T; Mizobuchi, Y; Nagahiro, S; Nakagawa, Y; Kumada, H

    2014-06-01

    The purpose of this study was to clarify the correlation between the radiation dose and histopathological findings in patients with glioblastoma multiforme (GBM) treated with boron neutron capture therapy (BNCT). Histopathological studies were performed on specimens from 8 patients, 3 had undergone salvage surgery and 5 were autopsied. For histopathological cure of GBM at the primary site, the optimal minimal dose to the gross tumor volume (GTV) and the clinical target volume (CTV) were 68Gy(w) and 44Gy(w), respectively. Copyright © 2014. Published by Elsevier Ltd.

  5. Boron neutron capture therapy (BNCT) for newly-diagnosed glioblastoma: comparison of clinical results obtained with BNCT and conventional treatment.

    PubMed

    Kageji, Teruyoshi; Nagahiro, Shinji; Mizobuchi, Yoshifumi; Matsuzaki, Kazuhito; Nakagawa, Yoshinobu; Kumada, Hiroaki

    2014-01-01

    The purpose of this study was to evaluate the clinical outcome of boron neutron capture therapy (BNCT) and conventional treatment in patients with newly diagnosed glioblastoma. Since 1998 we treated 23 newly-diagosed GBM patients with BNCT without any additional chemotherapy. Their median survival time was 19.5 months; the 2-, 3-, and 5-year survival rates were 31.8%, 22.7%, and 9.1%, respectively. The clinical results of BNCT in patients with GBM are similar to those of recent conventional treatments based on radiotherapy with concomitant and adjuvant temozolomide.

  6. Discrepancies in Autonomy and Relatedness Promoting Behaviors of Substance Using Mothers and Their Children: The Effects of a Family Systems Intervention

    PubMed Central

    Slesnick, Natasha

    2016-01-01

    Parents’ and children’s autonomy and relatedness behaviors are associated with a wide range of child outcomes. Yet, little is known about how parents and children’s autonomy and relatedness behaviors jointly influence child outcomes. The current study captured this joint influence by exploring the longitudinal trajectory of mother–child discrepancies in autonomy and relatedness behaviors and its association with child problem behaviors. The effects of a family systems intervention on the trajectory of mother–child discrepancies were also examined. The sample included 183 substance using mothers and their children (M age = 11.54 years, SD = 2.55, range 8–16; 48 % females). Both the mother and child completed an assessment at baseline, 6- and 18-month post-baseline. A person-centered analysis identified subgroups varying in mother–child discrepancy patterns in their autonomy and relatedness behaviors. The results also showed that participation in the family systems therapy was associated with decreased mother–child discrepancies, and also a synchronous increase in mother’s and child’s autonomy and relatedness. Additionally, increased mother–child discrepancies and mother–child dyads showing no change in autonomy and relatedness was associated with higher levels of children’s problem behaviors. The findings reveal a dynamic process of mother–child discrepancies in autonomy and relatedness behaviors related to child outcomes. The findings also support the effectiveness of the family systems therapy, and highlight the importance of understanding the complexities in family interactions when explaining children’s problem behaviors. PMID:27480271

  7. NEUTRON CAPTURE THERAPY OF A CEREBELLAR HEMANGIOSARCOMA AFTER SURGICAL AND RADIATION TREATMENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farr, L.E.; Yamamoto, L.Y.

    1961-10-01

    A patient with a hioghly maliognant vascular sarcoma of the cerebellum was treated hv neutron capture therapy. Almost complete elimination of the neoplasm was attained. Other than the skin, normal tissues about and within the neoplastioc mass did not appear to be adversely affected. An unusual and unexpected bulbar conjunctivitis was observed as a complication. The degree of control attained by this experimental procedure was more positive than that previously attained by surgery or conventional x-ray therapy. This is the first attempt to control an intracranial tumor other than glioblastoma multiforme by this procedure. The patient is noteworthy for themore » extreme retention of carbon dioxiode, 60 milli-equivalents per liter in the blood, apparently resulting from functional disturbances of the respiratory center. (auth)« less

  8. Universal algorithm for diagnosis of biventricular capture in patients with cardiac resynchronization therapy.

    PubMed

    Jastrzebski, Marek; Kukla, Piotr; Fijorek, Kamil; Czarnecka, Danuta

    2014-08-01

    An accurate and universal method for diagnosis of biventricular (BiV) capture using a standard 12-lead electrocardiogram (ECG) would be useful for assessment of cardiac resynchronization therapy (CRT) patients. Our objective was to develop and validate such an ECG method for BiV capture diagnosis that would be independent of pacing lead positions-a major confounder that significantly influences the morphologies of paced QRS complexes. On the basis of an evaluation of 789 ECGs of 443 patients with heart failure and various right ventricular (RV) and left ventricular (LV) lead positions, the following algorithm was constructed and validated. BiV capture was diagnosed if the QRS in lead I was predominantly negative and either V1 QRS was predominantly positive or V6 QRS was of negative onset and predominantly negative (step 1), or if QRS complex duration was <160 ms (step 2). All other ECGs were classified as loss of LV capture. The algorithm showed good accuracy (93%), sensitivity (97%), and specificity (90%) for detection of loss of LV capture. The performance of the algorithm did not differ among apical, midseptal, and outflow tract RV lead positions and various LV lead positions. LV capture leaves diagnostic hallmarks in the fused BiV QRS related to different vectors of depolarization and more rapid depolarization of the ventricles. An accurate two-step ECG algorithm for BiV capture diagnosis was developed and validated. This algorithm is universally applicable to all CRT patients, regardless of the positions of the pacing leads. ©2014 Wiley Periodicals, Inc.

  9. The role of day-to-day emotions, sleep, and social interactions in pediatric anxiety treatment.

    PubMed

    Wallace, Meredith L; McMakin, Dana L; Tan, Patricia Z; Rosen, Dana; Forbes, Erika E; Ladouceur, Cecile D; Ryan, Neal D; Siegle, Greg J; Dahl, Ronald E; Kendall, Philip C; Mannarino, Anthony; Silk, Jennifer S

    2017-03-01

    Do day-to-day emotions, social interactions, and sleep play a role in determining which anxious youth respond to supportive child-centered therapy (CCT) versus cognitive behavioral therapy (CBT)? We explored whether measures of day-to-day functioning (captured through ecological momentary assessment, sleep diary, and actigraphy), along with clinical and demographic measures, were predictors or moderators of treatment outcome in 114 anxious youth randomized to CCT or CBT. We statistically combined individual moderators into a single, optimal composite moderator to characterize subgroups for which CCT or CBT may be preferable. The strongest predictors of better outcome included: (a) experiencing higher positive affect when with one's mother and (b) fewer self-reported problems with sleep duration. The composite moderator indicated that youth for whom CBT was indicated had: (a) more day-to-day sleep problems related to sleep quality, efficiency, and waking, (b) day-to-day negative events related to interpersonal concerns, (c) more DSM-IV anxiety diagnoses, and (d) college-educated parents. These findings illustrate the value of both day-to-day functioning characteristics and more traditional sociodemographic and clinical characteristics in identifying optimal anxiety treatment assignment. Future studies will need to enhance the practicality of real-time measures for use in clinical decision making and evaluate additional anxiety treatments. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Problem solving therapy - use and effectiveness in general practice.

    PubMed

    Pierce, David

    2012-09-01

    Problem solving therapy (PST) is one of the focused psychological strategies supported by Medicare for use by appropriately trained general practitioners. This article reviews the evidence base for PST and its use in the general practice setting. Problem solving therapy involves patients learning or reactivating problem solving skills. These skills can then be applied to specific life problems associated with psychological and somatic symptoms. Problem solving therapy is suitable for use in general practice for patients experiencing common mental health conditions and has been shown to be as effective in the treatment of depression as antidepressants. Problem solving therapy involves a series of sequential stages. The clinician assists the patient to develop new empowering skills, and then supports them to work through the stages of therapy to determine and implement the solution selected by the patient. Many experienced GPs will identify their own existing problem solving skills. Learning about PST may involve refining and focusing these skills.

  11. Metalloporphyrins and their uses as imageable tumor-targeting agents for radiation therapy

    DOEpatents

    Miura, Michiko; Slatkin, Daniel N.

    2003-05-20

    The present invention covers halogenated derivatives of boronated porphyrins containing multiple carborane cages having the formula ##STR1## which selectively accumulate in neoplastic tissue within the irradiation volume and thus can be used in cancer therapies including, but not limited to, boron neutron- capture therapy and photodynamic therapy. The present invention also covers methods for using these halogenated derivatives of boronated porphyrins in tumor imaging and cancer treatment.

  12. Use of novel metalloporphyrins as imageable tumor-targeting agents for radiation therapy

    DOEpatents

    Miura, Michiko; Slatkin, Daniel N.

    2005-10-04

    The present invention covers halogenated derivatives of boronated phorphyrins containing multiple carborane cages having the formula ##STR1## which selectively accumulate in neoplastic tissue within the irradiation volume and thus can be used in cancer therapies including, but not limited to, boron neutron-capture therapy and photodynamic therapy. The present invention also covers methods for using these halogenated derivatives of boronated porphyrins in tumor imaging and cancer treatment.

  13. Couples' Reports of Relationship Problems in a Naturalistic Therapy Setting

    ERIC Educational Resources Information Center

    Boisvert, Marie-Michele; Wright, John; Tremblay, Nadine; McDuff, Pierre

    2011-01-01

    Understanding couples' relationship problems is fundamental to couple therapy. Although research has documented common relationship problems, no study has used open-ended questions to explore problems in couples seeking therapy in naturalistic settings. The present study used a reliable coding system to explore the relationship problems reported…

  14. Non-responders to cardiac resynchronization therapy: Insights from multimodality imaging and electrocardiography. A brief review.

    PubMed

    Carità, Patrizia; Corrado, Egle; Pontone, Gianluca; Curnis, Antonio; Bontempi, Luca; Novo, Giuseppina; Guglielmo, Marco; Ciaramitaro, Gianfranco; Assennato, Pasquale; Novo, Salvatore; Coppola, Giuseppe

    2016-12-15

    Cardiac resynchronization therapy (CRT) is a successful strategy for heart failure (HF) patients. The pre-requisite for the response is the evidence of electrical dyssynchrony on the surface electrocardiogram usually as left bundle branch block (LBBB). Non-response to CRT is a significant problem in clinical practice. Patient selection, inadequate delivery and sub-optimal left ventricle lead position may be important causes. In an effort to improve CRT response multimodality imaging (especially echocardiography, computed tomography and cardiac magnetic resonance) could play a decisive role and extensive literature has been published on the matter. However, we are so far from routinary use in clinical practice. Electrocardiography (with respect to left ventricle capture and QRS narrowing) may represent a simple and low cost approach for early prediction of potential non-responder, with immediate practical implications. This brief review covers the current recommendations for CRT in HF patients with particular attention to the potential benefits of multimodality imaging and electrocardiography in improving response rate. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Hydrodynamics of the Capture Zone of a Partially Penetrating Well in a Confined Aquifer

    NASA Astrophysics Data System (ADS)

    Faybishenko, Boris A.; Javandel, Iraj; Witherspoon, Paul A.

    1995-04-01

    In the pump and treat approach to the problem of managing a contaminated aquifer, a key problem is to design an effective capture system that collects only the polluted groundwater without allowing any of it to escape. At present, it is customary to design a capture system using fully penetrating withdrawal wells. Very often, however, only part of the vertical thickness of the aquifer is contaminated, so the question may arise whether a more efficient capture system can be achieved using partially penetrating wells. Very little work has been done on the application of partially penetrating wells to this problem. A new semianalytic method that can be used in determining the geometry of the capture zone for steady state flow to a partially penetrating well that is screened from the top (or from the bottom) of a confined aquifer has been developed. By combining the velocity potentials for flow to the well with that for the regional flow field, a three-dimensional velocity potential that can be used in determining the complete geometry of the capture surface has been developed. The results have shown that with a constant pumping rate the maximum horizontal extent of the capture surface at the top (or bottom) of the aquifer increases as the degree of penetration decreases. As one would expect, the maximum vertical extent increases as the depth of penetration increases. Thus, if one knows the actual location of the contaminant plume, an appropriate combination of the degree of penetration and pumping rate can be selected to create an effective capture zone.

  16. Asymmetric capture of Dirac dark matter by the Sun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blennow, Mattias; Clementz, Stefan

    2015-08-18

    Current problems with the solar model may be alleviated if a significant amount of dark matter from the galactic halo is captured in the Sun. We discuss the capture process in the case where the dark matter is a Dirac fermion and the background halo consists of equal amounts of dark matter and anti-dark matter. By considering the case where dark matter and anti-dark matter have different cross sections on solar nuclei as well as the case where the capture process is considered to be a Poisson process, we find that a significant asymmetry between the captured dark particles andmore » anti-particles is possible even for an annihilation cross section in the range expected for thermal relic dark matter. Since the captured number of particles are competitive with asymmetric dark matter models in a large range of parameter space, one may expect solar physics to be altered by the capture of Dirac dark matter. It is thus possible that solutions to the solar composition problem may be searched for in these type of models.« less

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blennow, Mattias; Clementz, Stefan, E-mail: emb@kth.se, E-mail: scl@kth.se

    Current problems with the solar model may be alleviated if a significant amount of dark matter from the galactic halo is captured in the Sun. We discuss the capture process in the case where the dark matter is a Dirac fermion and the background halo consists of equal amounts of dark matter and anti-dark matter. By considering the case where dark matter and anti-dark matter have different cross sections on solar nuclei as well as the case where the capture process is considered to be a Poisson process, we find that a significant asymmetry between the captured dark particles andmore » anti-particles is possible even for an annihilation cross section in the range expected for thermal relic dark matter. Since the captured number of particles are competitive with asymmetric dark matter models in a large range of parameter space, one may expect solar physics to be altered by the capture of Dirac dark matter. It is thus possible that solutions to the solar composition problem may be searched for in these type of models.« less

  18. Synthesis and biological evaluation of new boron-containing chlorin derivatives as agents for both photodynamic therapy and boron neutron capture therapy of cancer.

    PubMed

    Asano, Ryuji; Nagami, Amon; Fukumoto, Yuki; Miura, Kaori; Yazama, Futoshi; Ito, Hideyuki; Sakata, Isao; Tai, Akihiro

    2014-03-01

    New boron-containing chlorin derivatives 9 and 13 as agents for both photodynamic therapy (PDT) and boron neutron capture therapy (BNCT) of cancer were synthesized from photoprotoporphyrin IX dimethyl ester (2) and L-4-boronophenylalanine-related compounds. The in vivo biodistribution and clearance of 9 and 13 were investigated in tumor-bearing mice. The time to maximum accumulation of compound 13 in tumor tissue was one-fourth of that of compound 9, and compound 13 showed rapid clearance from normal tissues within 24h after injection. The in vivo therapeutic efficacy of PDT using 13 was evaluated by measuring tumor growth rates in tumor-bearing mice with 660 nm light-emitting diode irradiation at 3h after injection of 13. Tumor growth was significantly inhibited by PDT using 13. These results suggested that 13 might be a good candidate for both PDT and BNCT of cancer. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Driving personalized medicine: capturing maximum net present value and optimal return on investment.

    PubMed

    Roth, Mollie; Keeling, Peter; Smart, Dave

    2010-01-01

    In order for personalized medicine to meet its potential future promise, a closer focus on the work being carried out today and the foundation it will provide for that future is imperative. While big picture perspectives of this still nascent shift in the drug-development process are important, it is more important that today's work on the first wave of targeted therapies is used to build specific benchmarking and financial models against which further such therapies may be more effectively developed. Today's drug-development teams need a robust tool to identify the exact drivers that will ensure the successful launch and rapid adoption of targeted therapies, and financial metrics to determine the appropriate resource levels to power those drivers. This special report will describe one such benchmarking and financial model that is specifically designed for the personalized medicine field and will explain how the use of this or similar models can help to capture the maximum net present value of targeted therapies and help to realize optimal return on investment.

  20. Final Stage in the Design of a Boron Neutron Capture Therapy facility at CEADEN, Cuba

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cabal, F. Padilla; Martin, G.

    A neutron beam simulation study is carried out to determine the most suitable neutron energy for treatment of shallow and deep-seated brain tumors in the context of Boron Neutron Capture Therapy (BNCT). Two figures-of-merit, the therapeutic gain and the neutron fluence are utilized as beam assessment parameters. An irradiation cavity is used instead of a parallel beam port for the therapy. Calculations are performed using the MCNP5 code. After the optimization of our beam-shaper a study of the dose distribution in the head, neck, tyroids, lungs and upper and middle spine had been made. The therapeutic gain is increased whilemore » the current required for one hour treatment is decreased in comparison with the trading prototypes of NG used for BNCT.« less

  1. Biological activity of N(4)-boronated derivatives of 2'-deoxycytidine, potential agents for boron-neutron capture therapy.

    PubMed

    Nizioł, Joanna; Uram, Łukasz; Szuster, Magdalena; Sekuła, Justyna; Ruman, Tomasz

    2015-10-01

    Boron-neutron capture therapy (BNCT) is a binary anticancer therapy that requires boron compound for nuclear reaction during which high energy alpha particles and lithium nuclei are formed. Unnatural, boron-containing nucleoside with hydrophobic pinacol moiety was investigated as a potential BNCT boron delivery agent. Biological properties of this compound are presented for the first time and prove that boron nucleoside has low cytotoxicity and that observed apoptotic effects suggest alteration of important functions of cancer cells. Mass spectrometry analysis of DNA from cancer cells proved that boron nucleoside is inserted into nucleic acids as a functional nucleotide derivative. NMR studies present very high degree of similarity of natural dG-dC base pair with dG-boron nucleoside system. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. A guided interview process to improve student pharmacists' identification of drug therapy problems.

    PubMed

    Rovers, John; Miller, Michael J; Koenigsfeld, Carrie; Haack, Sally; Hegge, Karly; McCleeary, Erin

    2011-02-10

    To measure agreement between advanced pharmacy practice experience students using a guided interview process and experienced clinical pharmacists using standard practices to identify drug therapy problems. Student pharmacists enrolled in an advanced pharmacy practice experience (APPE) and clinical pharmacists conducted medication therapy management interviews to identify drug therapy problems in elderly patients recruited from the community. Student pharmacists used a guided interview tool, while clinical pharmacists' interviews were conducted using their usual and customary practices. Student pharmacists also were surveyed to determine their perceptions of the interview tool. Fair to moderate agreement was observed on student and clinical pharmacists' identification of 4 of 7 drug therapy problems. Of those, agreement was significantly higher than chance for 3 drug therapy problems (adverse drug reaction, dosage too high, and needs additional drug therapy) and not significant for 1 (unnecessary drug therapy). Students strongly agreed that the interview tool was useful but agreed less strongly on recommending its use in practice. The guided interview process served as a useful teaching aid to assist student pharmacists to identify drug therapy problems.

  3. A Guided Interview Process to Improve Student Pharmacists' Identification of Drug Therapy Problems

    PubMed Central

    Miller, Michael J.; Koenigsfeld, Carrie; Haack, Sally; Hegge, Karly; McCleeary, Erin

    2011-01-01

    Objective To measure agreement between advanced pharmacy practice experience students using a guided interview process and experienced clinical pharmacists using standard practices to identify drug therapy problems. Methods Student pharmacists enrolled in an advanced pharmacy practice experience (APPE) and clinical pharmacists conducted medication therapy management interviews to identify drug therapy problems in elderly patients recruited from the community. Student pharmacists used a guided interview tool, while clinical pharmacists' interviews were conducted using their usual and customary practices. Student pharmacists also were surveyed to determine their perceptions of the interview tool. Results Fair to moderate agreement was observed on student and clinical pharmacists' identification of 4 of 7 drug therapy problems. Of those, agreement was significantly higher than chance for 3 drug therapy problems (adverse drug reaction, dosage too high, and needs additional drug therapy) and not significant for 1 (unnecessary drug therapy). Students strongly agreed that the interview tool was useful but agreed less strongly on recommending its use in practice. Conclusions The guided interview process served as a useful teaching aid to assist student pharmacists to identify drug therapy problems. PMID:21451770

  4. Evaluation of a Gait Assessment Module Using 3D Motion Capture Technology

    PubMed Central

    Baskwill, Amanda J.; Belli, Patricia; Kelleher, Leila

    2017-01-01

    Background Gait analysis is the study of human locomotion. In massage therapy, this observation is part of an assessment process that informs treatment planning. Massage therapy students must apply the theory of gait assessment to simulated patients. At Humber College, the gait assessment module traditionally consists of a textbook reading and a three-hour, in-class session in which students perform gait assessment on each other. In 2015, Humber College acquired a three-dimensional motion capture system. Purpose The purpose was to evaluate the use of 3D motion capture in a gait assessment module compared to the traditional gait assessment module. Participants Semester 2 massage therapy students who were enrolled in Massage Theory 2 (n = 38). Research Design Quasi-experimental, wait-list comparison study. Intervention The intervention group participated in an in-class session with a Qualisys motion capture system. Main Outcome Measure(s) The outcomes included knowledge and application of gait assessment theory as measured by quizzes, and students’ satisfaction as measured through a questionnaire. Results There were no statistically significant differences in baseline and post-module knowledge between both groups (pre-module: p = .46; post-module: p = .63). There was also no difference between groups on the final application question (p = .13). The intervention group enjoyed the in-class session because they could visualize the content, whereas the comparison group enjoyed the interactivity of the session. The intervention group recommended adding the assessment of gait on their classmates to their experience. Both groups noted more time was needed for the gait assessment module. Conclusions Based on the results of this study, it is recommended that the gait assessment module combine both the traditional in-class session and the 3D motion capture system. PMID:28293329

  5. Study of low energy neutron beam formation based on GEANT4 simulations

    NASA Astrophysics Data System (ADS)

    Avagyan, R.; Avetisyan, R.; Ivanyan, V.; Kerobyan, I.

    2017-07-01

    The possibility of obtaining thermal/epithermal energy neutron beams using external protons from cyclotron C18/18 is studied based on GEANT4 simulations. This study will be the basis of the Beam Shaped Assembly (BSA) development for future Boron Neutron Capture Therapy (BNCT). Proton induced reactions on 9Be target are considered as a neutron source, and dependence of neutron yield on target thickness is investigated. The problem of reducing the ratio of gamma to neutron yields by inserting a lead sheet after the beryllium target is studied as well. By GEANT4 modeling the optimal thicknesses of 9Be target and lead absorber are determined and the design characteristics of beam shaping assembly, including the materials and thicknesses of reflector and moderator are considered.

  6. Development of high intensity ion sources for a Tandem-Electrostatic-Quadrupole facility for Accelerator-Based Boron Neutron Capture Therapy.

    PubMed

    Bergueiro, J; Igarzabal, M; Sandin, J C Suarez; Somacal, H R; Vento, V Thatar; Huck, H; Valda, A A; Repetto, M; Kreiner, A J

    2011-12-01

    Several ion sources have been developed and an ion source test stand has been mounted for the first stage of a Tandem-Electrostatic-Quadrupole facility For Accelerator-Based Boron Neutron Capture Therapy. A first source, designed, fabricated and tested is a dual chamber, filament driven and magnetically compressed volume plasma proton ion source. A 4 mA beam has been accelerated and transported into the suppressed Faraday cup. Extensive simulations of the sources have been performed using both 2D and 3D self-consistent codes. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Boron neutron capture therapy (BNCT) as a new approach for clear cell sarcoma (CCS) treatment: Trial using a lung metastasis model of CCS.

    PubMed

    Andoh, Tooru; Fujimoto, Takuya; Suzuki, Minoru; Sudo, Tamotsu; Sakurai, Yoshinori; Tanaka, Hiroki; Fujita, Ikuo; Fukase, Naomasa; Moritake, Hiroshi; Sugimoto, Tohru; Sakuma, Toshiko; Sasai, Hiroshi; Kawamoto, Teruya; Kirihata, Mitsunori; Fukumori, Yoshinobu; Akisue, Toshihiro; Ono, Koji; Ichikawa, Hideki

    2015-12-01

    Clear cell sarcoma (CCS) is a rare malignant tumor with a poor prognosis. In the present study, we established a lung metastasis animal model of CCS and investigated the therapeutic effect of boron neutron capture therapy (BNCT) using p-borono-L-phenylalanine (L-BPA). Biodistribution data revealed tumor-selective accumulation of (10)B. Unlike conventional gamma-ray irradiation, BNCT significantly suppressed tumor growth without damaging normal tissues, suggesting that it may be a potential new therapeutic option to treat CCS lung metastases. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Boron neutron capture therapy for clear cell sarcoma (CCS): biodistribution study of p-borono-L-phenylalanine in CCS-bearing animal models.

    PubMed

    Andoh, T; Fujimoto, T; Sudo, T; Fujita, I; Imabori, M; Moritake, H; Sugimoto, T; Sakuma, Y; Takeuchi, T; Kawabata, S; Kirihata, M; Akisue, T; Yayama, K; Kurosaka, M; Miyatake, S; Fukumori, Y; Ichikawa, H

    2011-12-01

    Clear cell sarcoma (CCS) is a rare melanocytic malignant tumor with a poor prognosis. Our previous study demonstrated that in vitro cultured CCS cells have the ability to highly uptake l-BPA and thus boron neutron capture therapy could be a new option for CCS treatment. This paper proved that a remarkably high accumulation of (10)B (45-74 ppm) in tumor was obtained even in a CCS-bearing animal with a well-controlled biodistribution followed by intravenous administration of L-BPA-fructose complex (500 mg BPA/kg). Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Experiments to increase the parameters of the vacuum insulation tandem accelerator for boron neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Kasatov, D. A.; Kolesnikov, J. A.; Koshkarev, A. M.; Kuznetsov, A. S.; Makarov, A. N.; Sokolova, E. O.; Sorokin, I. N.; Sycheva, T. V.; Taskaev, S. Yu.; Shchudlo, I. M.

    2016-12-01

    An epithermal neutron source that is based on a vacuum insulation tandem accelerator (VITA) and lithium target was created in the Budker Institute of Nuclear Physics for the development of boron neutron capture therapy (BNCT). A stationary proton beam with 2 MeV energy and 1.6 mA current has been obtained. To carry out BNCT, it is necessary to increase the beam parameters up to 2.3 MeV and 3 mA. Ways to increase the parameters of the proton beam have been proposed and discussed in this paper. The results of the experiments are presented.

  10. Application of an ultraminiature thermal neutron monitor for irradiation field study of accelerator-based neutron capture therapy

    PubMed Central

    Ishikawa, Masayori; Tanaka, Kenichi; Endo, Satrou; Hoshi, Masaharu

    2015-01-01

    Abstract Phantom experiments to evaluate thermal neutron flux distribution were performed using the Scintillator with Optical Fiber (SOF) detector, which was developed as a thermal neutron monitor during boron neutron capture therapy (BNCT) irradiation. Compared with the gold wire activation method and Monte Carlo N-particle (MCNP) calculations, it was confirmed that the SOF detector is capable of measuring thermal neutron flux as low as 105 n/cm2/s with sufficient accuracy. The SOF detector will be useful for phantom experiments with BNCT neutron fields from low-current accelerator-based neutron sources. PMID:25589504

  11. Molecular Medicine: Synthesis and In Vivo Detection of Agents for use in Boron Neutron Capture Therapy. Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kabalka, G. W.

    2005-06-28

    The primary objective of the project was the development of in vivo methods for the detection and evaluation of tumors in humans. The project was focused on utilizing positron emission tomography (PET) to monitor the distribution and pharamacokinetics of a current boron neutron capture therapy (BNCT) agent, p-boronophenylalanine (BPA) by labeling it with a fluorine-18, a positron emitting isotope. The PET data was then used to develop enhanced treatment planning protocols. The study also involved the synthesis of new tumor selective BNCTagents that could be labeled with radioactive nuclides for the in vivo detection of boron.

  12. A microdosimetric study of {sup 10}B(n,{alpha}){sup 7}Li and {sup 157}Gd(n,{gamma}) reactions for neutron capture therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, C.K.C.; Sutton, M.; Evans, T.M.

    1999-01-01

    This paper presents the microdosimetric analysis for the most interesting cell survival experiment recently performed at the Brookhaven National Laboratory (BNL). In this experiment, the cells were first treated with a gadolinium (Gd) labeled tumor-seeking boronated porphyrin (Gd-BOPP) or with BOPP alone, and then irradiated with thermal neutrons. The resulting cell-survival curves indicate that the {sup 157}Gd(n,{gamma}) reactions are very effective in cell killing. The death of a cell treated with Gd-BOPP was attributed to either the {sup 10}B(n,{alpha}){sup 7}Li reactions or the {sup 157}Gd(n,{gamma}) reactions (or both). However, the quantitative relationship between the two types of reaction and themore » cell-survival fraction was not clear. This paper presents the microdosimetric analysis for the BNL experiment based on the measured experimental parameters, and the results clearly suggest a quantitative relationship between the two types of reaction and the cell survival fraction. The results also suggest new research in gadolinium neutron capture therapy (GdNCT) which may lead to a more practical modality than the boron neutron capture therapy (BNCT) for treating cancers.« less

  13. Preliminary dosimetric study on feasibility of multi-beam boron neutron capture therapy in patients with diffuse intrinsic pontine glioma without craniotomy.

    PubMed

    Lee, Jia-Cheng; Chuang, Keh-Shih; Chen, Yi-Wei; Hsu, Fang-Yuh; Chou, Fong-In; Yen, Sang-Hue; Wu, Yuan-Hung

    2017-01-01

    Diffuse intrinsic pontine glioma is a very frustrating disease. Since the tumor infiltrates the brain stem, surgical removal is often impossible. For conventional radiotherapy, the dose constraint of the brain stem impedes attempts at further dose escalation. Boron neutron capture therapy (BNCT), a targeted radiotherapy, carries the potential to selectively irradiate tumors with an adequate dose while sparing adjacent normal tissue. In this study, 12 consecutive patients treated with conventional radiotherapy in our institute were reviewed to evaluate the feasibility of BNCT. NCTPlan Ver. 1.1.44 was used for dose calculations. Compared with two and three fields, the average maximal dose to the normal brain may be lowered to 7.35 ± 0.72 Gy-Eq by four-field irradiation. The mean ratio of minimal dose to clinical target volume and maximal dose to normal tissue was 2.41 ± 0.26 by four-field irradiation. A therapeutic benefit may be expected with multi-field boron neutron capture therapy to treat diffuse intrinsic pontine glioma without craniotomy, while the maximal dose to the normal brain would be minimized by using the four-field setting.

  14. Preliminary dosimetric study on feasibility of multi-beam boron neutron capture therapy in patients with diffuse intrinsic pontine glioma without craniotomy

    PubMed Central

    Lee, Jia-Cheng; Chuang, Keh-Shih; Chen, Yi-Wei; Hsu, Fang-Yuh; Chou, Fong-In; Yen, Sang-Hue

    2017-01-01

    Diffuse intrinsic pontine glioma is a very frustrating disease. Since the tumor infiltrates the brain stem, surgical removal is often impossible. For conventional radiotherapy, the dose constraint of the brain stem impedes attempts at further dose escalation. Boron neutron capture therapy (BNCT), a targeted radiotherapy, carries the potential to selectively irradiate tumors with an adequate dose while sparing adjacent normal tissue. In this study, 12 consecutive patients treated with conventional radiotherapy in our institute were reviewed to evaluate the feasibility of BNCT. NCTPlan Ver. 1.1.44 was used for dose calculations. Compared with two and three fields, the average maximal dose to the normal brain may be lowered to 7.35 ± 0.72 Gy-Eq by four-field irradiation. The mean ratio of minimal dose to clinical target volume and maximal dose to normal tissue was 2.41 ± 0.26 by four-field irradiation. A therapeutic benefit may be expected with multi-field boron neutron capture therapy to treat diffuse intrinsic pontine glioma without craniotomy, while the maximal dose to the normal brain would be minimized by using the four-field setting. PMID:28662135

  15. Democratisation or Management and Corporate Capture?: Theses on the Governance Crisis of Australia's Semi-Privatised Public Universities

    ERIC Educational Resources Information Center

    Bonnell, Andrew G.

    2016-01-01

    This paper proceeds from the view that managerial capture has already become a fundamental problem after a couple of decades of largely untrammelled managerialism in our public universities, and that this problem is likely to be compounded by further shifts towards deregulation and de facto privatisation, which is the direction that current…

  16. Using Multiple Calibration Indices in Order to Capture the Complex Picture of What Affects Students' Accuracy of Feeling of Confidence

    ERIC Educational Resources Information Center

    Boekaerts, Monique; Rozendaal, Jeroen S.

    2010-01-01

    The present study used multiple calibration indices to capture the complex picture of fifth graders' calibration of feeling of confidence in mathematics. Specifically, the effects of gender, type of mathematical problem, instruction method, and time of measurement (before and after problem solving) on calibration skills were investigated. Fourteen…

  17. A New Approach for Identifying Patients with Undiagnosed Chronic Obstructive Pulmonary Disease

    PubMed Central

    Mannino, David; Leidy, Nancy Kline; Malley, Karen G.; Bacci, Elizabeth D.; Barr, R. Graham; Bowler, Russ P.; Han, MeiLan K.; Houfek, Julia F.; Make, Barry; Meldrum, Catherine A.; Rennard, Stephen; Thomashow, Byron; Walsh, John; Yawn, Barbara P.

    2017-01-01

    Rationale: Chronic obstructive pulmonary disease (COPD) is often unrecognized and untreated. Objectives: To develop a method for identifying undiagnosed COPD requiring treatment with currently available therapies (FEV1 <60% predicted and/or exacerbation risk). Methods: We conducted a multisite, cross-sectional, case-control study in U.S. pulmonary and primary care clinics that recruited subjects from primary care settings. Cases were patients with COPD and at least one exacerbation in the past year or FEV1 less than 60% of predicted without exacerbation in the past year. Control subjects were persons with no COPD or with mild COPD (FEV1 ≥60% predicted, no exacerbation in the past year). In random forests analyses, we identified the smallest set of questions plus peak expiratory flow (PEF) with optimal sensitivity (SN) and specificity (SP). Measurements and Main Results: PEF and spirometry were recorded in 186 cases and 160 control subjects. The mean (SD) age of the sample population was 62.7 (10.1) years; 55% were female; 86% were white; and 16% had never smoked. The mean FEV1 percent predicted for cases was 42.5% (14.2%); for control subjects, it was 82.5% (15.7%). A five-item questionnaire, CAPTURE (COPD Assessment in Primary Care to Identify Undiagnosed Respiratory Disease and Exacerbation Risk), was used to assess exposure, breathing problems, tiring easily, and acute respiratory illnesses. CAPTURE exhibited an SN of 95.7% and an SP of 44.4% for differentiating cases from all control subjects, and an SN of 95.7% and an SP of 67.8% for differentiating cases from no-COPD control subjects. The PEF (males, <350 L/min; females, <250 L/min) SN and SP were 88.0% and 77.5%, respectively, for differentiating cases from all control subjects, and they were 88.0% and 90.8%, respectively, for distinguishing cases from no-COPD control subjects. The CAPTURE plus PEF exhibited improved SN and SP for all cases versus all control subjects (89.7% and 78.1%, respectively) and for all cases versus no-COPD control subjects (89.7% and 93.1%, respectively). Conclusions: CAPTURE with PEF can identify patients with COPD who would benefit from currently available therapy and require further diagnostic evaluation. Clinical trial registered with clinicaltrials.gov (NCT01880177). PMID:27783539

  18. Simulating variable source problems via post processing of individual particle tallies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bleuel, D.L.; Donahue, R.J.; Ludewigt, B.A.

    2000-10-20

    Monte Carlo is an extremely powerful method of simulating complex, three dimensional environments without excessive problem simplification. However, it is often time consuming to simulate models in which the source can be highly varied. Similarly difficult are optimization studies involving sources in which many input parameters are variable, such as particle energy, angle, and spatial distribution. Such studies are often approached using brute force methods or intelligent guesswork. One field in which these problems are often encountered is accelerator-driven Boron Neutron Capture Therapy (BNCT) for the treatment of cancers. Solving the reverse problem of determining the best neutron source formore » optimal BNCT treatment can be accomplished by separating the time-consuming particle-tracking process of a full Monte Carlo simulation from the calculation of the source weighting factors which is typically performed at the beginning of a Monte Carlo simulation. By post-processing these weighting factors on a recorded file of individual particle tally information, the effect of changing source variables can be realized in a matter of seconds, instead of requiring hours or days for additional complete simulations. By intelligent source biasing, any number of different source distributions can be calculated quickly from a single Monte Carlo simulation. The source description can be treated as variable and the effect of changing multiple interdependent source variables on the problem's solution can be determined. Though the focus of this study is on BNCT applications, this procedure may be applicable to any problem that involves a variable source.« less

  19. Problem-solving therapy and supportive therapy in older adults with major depression and executive dysfunction.

    PubMed

    Areán, Patricia A; Raue, Patrick; Mackin, R Scott; Kanellopoulos, Dora; McCulloch, Charles; Alexopoulos, George S

    2010-11-01

    The purpose of this study was to determine whether problem-solving therapy is an effective treatment in older patients with depression and executive dysfunction, a population likely to be resistant to antidepressant drugs. Participants were adults age 60 and older with major depression and executive dysfunction. Problem-solving therapy was modified to be accessible to this population. Participants were randomly assigned to 12 weekly sessions of problem-solving therapy or supportive therapy and assessed at weeks 3, 6, 9, and 12. Of the 653 individuals referred for this study, 221 met selection criteria and were enrolled in the study. Reduction of depressive symptom severity was comparable for the two treatment groups during the first 6 weeks of treatment, but at weeks 9 and 12 the problem-solving therapy group had a greater reduction in symptom severity, a greater response rate, and a greater remission rate than the supportive therapy group (response rates at week 9: 47.1% and 29.3%; at week 12:56.7% and 34.0%; remission rates at week 9: 37.9% and 21.7%; at week 12: 45.6% and 27.8%). Problem-solving therapy yielded one additional response or remission over supportive therapy for every 4.4-5.6 patients by the end of the trial. These results suggest that problem-solving therapy is effective in reducing depressive symptoms and leading to treatment response and remission in a considerable number of older patients with major depression and executive dysfunction. The clinical value of this finding is that problem-solving therapy may be a treatment alternative in an older patient population likely to be resistant to pharmacotherapy.

  20. The Generic Data Capture Facility

    NASA Technical Reports Server (NTRS)

    Connell, Edward B.; Barnes, William P.; Stallings, William H.

    1987-01-01

    The Generic Data Capture Facility, which can provide data capture support for a variety of different types of spacecraft while enabling operations costs to be carefully controlled, is discussed. The data capture functions, data protection, isolation of users from data acquisition problems, data reconstruction, and quality and accounting are addressed. The TDM and packet data formats utilized by the system are described, and the development of generic facilities is considered.

  1. Early Design Choices: Capture, Model, Integrate, Analyze, Simulate

    NASA Technical Reports Server (NTRS)

    Malin, Jane T.

    2004-01-01

    I. Designs are constructed incrementally to meet requirements and solve problems: a) Requirements types: objectives, scenarios, constraints, ilities. etc. b) Problem/issue types: risk/safety, cost/difficulty, interaction, conflict, etc. II. Capture requirements, problems and solutions: a) Collect design and analysis products and make them accessible for integration and analysis; b) Link changes in design requirements, problems and solutions; and c) Harvest design data for design models and choice structures. III. System designs are constructed by multiple groups designing interacting subsystems a) Diverse problems, choice criteria, analysis methods and point solutions. IV. Support integration and global analysis of repercussions: a) System implications of point solutions; b) Broad analysis of interactions beyond totals of mass, cost, etc.

  2. A Design Support Framework through Dynamic Deployment of Hypothesis and Verification in the Design Process

    NASA Astrophysics Data System (ADS)

    Nomaguch, Yutaka; Fujita, Kikuo

    This paper proposes a design support framework, named DRIFT (Design Rationale Integration Framework of Three layers), which dynamically captures and manages hypothesis and verification in the design process. A core of DRIFT is a three-layered design process model of action, model operation and argumentation. This model integrates various design support tools and captures design operations performed on them. Action level captures the sequence of design operations. Model operation level captures the transition of design states, which records a design snapshot over design tools. Argumentation level captures the process of setting problems and alternatives. The linkage of three levels enables to automatically and efficiently capture and manage iterative hypothesis and verification processes through design operations over design tools. In DRIFT, such a linkage is extracted through the templates of design operations, which are extracted from the patterns embeded in design tools such as Design-For-X (DFX) approaches, and design tools are integrated through ontology-based representation of design concepts. An argumentation model, gIBIS (graphical Issue-Based Information System), is used for representing dependencies among problems and alternatives. A mechanism of TMS (Truth Maintenance System) is used for managing multiple hypothetical design stages. This paper also demonstrates a prototype implementation of DRIFT and its application to a simple design problem. Further, it is concluded with discussion of some future issues.

  3. First-order logic theory for manipulating clinical practice guidelines applied to comorbid patients: a case study.

    PubMed

    Michalowski, Martin; Wilk, Szymon; Tan, Xing; Michalowski, Wojtek

    2014-01-01

    Clinical practice guidelines (CPGs) implement evidence-based medicine designed to help generate a therapy for a patient suffering from a single disease. When applied to a comorbid patient, the concurrent combination of treatment steps from multiple CPGs is susceptible to adverse interactions in the resulting combined therapy (i.e., a therapy established according to all considered CPGs). This inability to concurrently apply CPGs has been shown to be one of the key shortcomings of CPG uptake in a clinical setting1. Several research efforts are underway to address this issue such as the K4CARE2 and GuideLine INteraction Detection Assistant (GLINDA)3 projects and our previous research on applying constraint logic programming to developing a consistent combined therapy for a comorbid patient4. However, there is no generalized framework for mitigation that effectively captures general characteristics of the problem while handling nuances such as time and ordering requirements imposed by specific CPGs. In this paper we propose a first-order logic-based (FOL) approach for developing a generalized framework of mitigation. This approach uses a meta-algorithm and entailment properties to mitigate (i.e., identify and address) adverse interactions introduced by concurrently applied CPGs. We use an illustrative case study of a patient suffering from type 2 diabetes being treated for an onset of severe rheumatoid arthritis to show the expressiveness and robustness of our proposed FOL-based approach, and we discuss its appropriateness as the basis for the generalized theory.

  4. 76 FR 61722 - National Heart, Lung, and Blood Institute; Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-05

    ... Institute Special Emphasis Panel, Data Coordinating Center for the Cardiovascular Cell Therapy Research... Special Emphasis Panel, Regional Clinical Center for the Cardiovascular Cell Therapy Research Network... Capture Agents for Cardiovascular Research. Date: October 24, 2011. Time: 1 p.m. to 3 p.m. Agenda: To...

  5. Changes in problem-solving appraisal after cognitive therapy for the prevention of suicide.

    PubMed

    Ghahramanlou-Holloway, M; Bhar, S S; Brown, G K; Olsen, C; Beck, A T

    2012-06-01

    Cognitive therapy has been found to be effective in decreasing the recurrence of suicide attempts. A theoretical aim of cognitive therapy is to improve problem-solving skills so that suicide no longer remains the only available option. This study examined the differential rate of change in problem-solving appraisal following suicide attempts among individuals who participated in a randomized controlled trial for the prevention of suicide. Changes in problem-solving appraisal from pre- to 6-months post-treatment in individuals with a recent suicide attempt, randomized to either cognitive therapy (n = 60) or a control condition (n = 60), were assessed by using the Social Problem-Solving Inventory-Revised, Short Form. Improvements in problem-solving appraisal were similarly observed for both groups within the 6-month follow-up. However, during this period, individuals assigned to the cognitive therapy condition demonstrated a significantly faster rate of improvement in negative problem orientation and impulsivity/carelessness. More specifically, individuals receiving cognitive therapy were significantly less likely to report a negative view toward life problems and impulsive/carelessness problem-solving style. Cognitive therapy for the prevention of suicide provides rapid changes within 6 months on negative problem orientation and impulsivity/carelessness problem-solving style. Given that individuals are at the greatest risk for suicide within 6 months of their last suicide attempt, the current study demonstrates that a brief cognitive intervention produces a rapid rate of improvement in two important domains of problem-solving appraisal during this sensitive period.

  6. Minimum required capture radius in a coplanar model of the aerial combat problem

    NASA Technical Reports Server (NTRS)

    Breakwell, J. V.; Merz, A. W.

    1977-01-01

    Coplanar aerial combat is modeled with constant speeds and specified turn rates. The minimum capture radius which will always permit capture, regardless of the initial conditions, is calculated. This 'critical' capture radius is also the maximum range which the evader can guarantee indefinitely if the initial range, for example, is large. A composite barrier is constructed which gives the boundary, at any heading, of relative positions for which the capture radius is less than critical.

  7. Boron neutron capture therapy for malignant melanoma: first clinical case report in China

    PubMed Central

    Yong, Zhong; Song, Zewen; Zhou, Yongmao; Liu, Tong; Zhang, Zizhu; Zhao, Yanzhong; Chen, Yang; Jin, Congjun; Chen, Xiang; Lu, Jianyun; Han, Rui; Li, Pengzhou; Sun, Xulong; Wang, Guohui; Shi, Guangqing; Zhu, Shaihong

    2016-01-01

    A phase I/II clinical trial for treating malignant melanoma by boron neutron capture therapy (BNCT) was designed to evaluate whether the world’s first in-hospital neutron irradiator (IHNI) was qualified for BNCT. In this clinical trial planning to enroll 30 patients, the first case was treated on August 19, 2014. We present the protocol of this clinical trial, the treating procedure, and the clinical outcome of this first case. Only grade 2 acute radiation injury was observed during the first four weeks after BNCT and the injury healed after treatment. No late radiation injury was found during the 24-month follow-up. Based on positron emission tomography-computed tomography (PET/CT) scan, pathological analysis and gross examination, the patient showed a complete response to BNCT, indicating that BNCT is a potent therapy against malignant melanoma and IHNI has the potential to enable the delivery of BNCT in hospitals. PMID:28174492

  8. SIENA Customer Problem Statement and Requirements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    L. Sauer; R. Clay; C. Adams

    2000-08-01

    This document describes the problem domain and functional requirements of the SIENA framework. The software requirements and system architecture of SIENA are specified in separate documents (called SIENA Software Requirement Specification and SIENA Software Architecture, respectively). While currently this version of the document describes the problems and captures the requirements within the Analysis domain (concentrating on finite element models), it is our intention to subsequent y expand this document to describe problems and capture requirements from the Design and Manufacturing domains. In addition, SIENA is designed to be extendible to support and integrate elements from the other domains (see SIENAmore » Software Architecture document).« less

  9. Building an information model (with the help of PSL/PSA). [Problem Statement Language/Problem Statement Analyzer

    NASA Technical Reports Server (NTRS)

    Callender, E. D.; Farny, A. M.

    1983-01-01

    Problem Statement Language/Problem Statement Analyzer (PSL/PSA) applications, which were once a one-step process in which product system information was immediately translated into PSL statements, have in light of experience been shown to result in inconsistent representations. These shortcomings have prompted the development of an intermediate step, designated the Product System Information Model (PSIM), which provides a basis for the mutual understanding of customer terminology and the formal, conceptual representation of that product system in a PSA data base. The PSIM is initially captured as a paper diagram, followed by formal capture in the PSL/PSA data base.

  10. A data model that captures clinical reasoning about patient problems.

    PubMed Central

    Barrows, R. C.; Johnson, S. B.

    1995-01-01

    We describe a data model that has been implemented for the CPMC Ambulatory Care System, and exemplify its function for patient problems. The model captures some nuances of clinical thinking about patients that are not accommodated in most other models, such as an evolution of clinical understanding about patient problems. A record of this understanding has clinical utility, and serves research interests as well as medical audit concerns. The model is described with an example, and advantages and limitations in the current implementation are discussed. PMID:8563311

  11. Hierarchical calibration and validation for modeling bench-scale solvent-based carbon capture. Part 1: Non-reactive physical mass transfer across the wetted wall column: Original Research Article: Hierarchical calibration and validation for modeling bench-scale solvent-based carbon capture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Chao; Xu, Zhijie; Lai, Canhai

    A hierarchical model calibration and validation is proposed for quantifying the confidence level of mass transfer prediction using a computational fluid dynamics (CFD) model, where the solvent-based carbon dioxide (CO2) capture is simulated and simulation results are compared to the parallel bench-scale experimental data. Two unit problems with increasing level of complexity are proposed to breakdown the complex physical/chemical processes of solvent-based CO2 capture into relatively simpler problems to separate the effects of physical transport and chemical reaction. This paper focuses on the calibration and validation of the first unit problem, i.e. the CO2 mass transfer across a falling ethanolaminemore » (MEA) film in absence of chemical reaction. This problem is investigated both experimentally and numerically using nitrous oxide (N2O) as a surrogate for CO2. To capture the motion of gas-liquid interface, a volume of fluid method is employed together with a one-fluid formulation to compute the mass transfer between the two phases. Bench-scale parallel experiments are designed and conducted to validate and calibrate the CFD models using a general Bayesian calibration. Two important transport parameters, e.g. Henry’s constant and gas diffusivity, are calibrated to produce the posterior distributions, which will be used as the input for the second unit problem to address the chemical adsorption of CO2 across the MEA falling film, where both mass transfer and chemical reaction are involved.« less

  12. A Large-Scale Study of Fingerprint Matching Systems for Sensor Interoperability Problem

    PubMed Central

    Hussain, Muhammad; AboAlSamh, Hatim; AlZuair, Mansour

    2018-01-01

    The fingerprint is a commonly used biometric modality that is widely employed for authentication by law enforcement agencies and commercial applications. The designs of existing fingerprint matching methods are based on the hypothesis that the same sensor is used to capture fingerprints during enrollment and verification. Advances in fingerprint sensor technology have raised the question about the usability of current methods when different sensors are employed for enrollment and verification; this is a fingerprint sensor interoperability problem. To provide insight into this problem and assess the status of state-of-the-art matching methods to tackle this problem, we first analyze the characteristics of fingerprints captured with different sensors, which makes cross-sensor matching a challenging problem. We demonstrate the importance of fingerprint enhancement methods for cross-sensor matching. Finally, we conduct a comparative study of state-of-the-art fingerprint recognition methods and provide insight into their abilities to address this problem. We performed experiments using a public database (FingerPass) that contains nine datasets captured with different sensors. We analyzed the effects of different sensors and found that cross-sensor matching performance deteriorates when different sensors are used for enrollment and verification. In view of our analysis, we propose future research directions for this problem. PMID:29597286

  13. Capturing the complexity of first opinion small animal consultations using direct observation

    PubMed Central

    Robinson, N. J.; Brennan, M. L.; Cobb, M.; Dean, R. S.

    2015-01-01

    Various different methods are currently being used to capture data from small animal consultations. The aim of this study was to develop a tool to record detailed data from consultations by direct observation. A second aim was to investigate the complexity of the consultation by examining the number of problems discussed per patient. A data collection tool was developed and used during direct observation of small animal consultations in eight practices. Data were recorded on consultation type, patient signalment and number of problems discussed. During 16 weeks of data collection, 1901 patients were presented. Up to eight problems were discussed for some patients; more problems were discussed during preventive medicine consultations than during first consultations (P<0.001) or revisits (P<0.001). Fewer problems were discussed for rabbits than cats (P<0.001) or dogs (P<0.001). Age was positively correlated with discussion of specific health problems and negatively correlated with discussion of preventive medicine. Consultations are complex with multiple problems frequently discussed, suggesting comorbidity may be common. Future research utilising practice data should consider how much of this complexity needs to be captured, and use appropriate methods accordingly. The findings here have implications for directing research and education as well as application in veterinary practice. PMID:25262057

  14. A Large-Scale Study of Fingerprint Matching Systems for Sensor Interoperability Problem.

    PubMed

    AlShehri, Helala; Hussain, Muhammad; AboAlSamh, Hatim; AlZuair, Mansour

    2018-03-28

    The fingerprint is a commonly used biometric modality that is widely employed for authentication by law enforcement agencies and commercial applications. The designs of existing fingerprint matching methods are based on the hypothesis that the same sensor is used to capture fingerprints during enrollment and verification. Advances in fingerprint sensor technology have raised the question about the usability of current methods when different sensors are employed for enrollment and verification; this is a fingerprint sensor interoperability problem. To provide insight into this problem and assess the status of state-of-the-art matching methods to tackle this problem, we first analyze the characteristics of fingerprints captured with different sensors, which makes cross-sensor matching a challenging problem. We demonstrate the importance of fingerprint enhancement methods for cross-sensor matching. Finally, we conduct a comparative study of state-of-the-art fingerprint recognition methods and provide insight into their abilities to address this problem. We performed experiments using a public database (FingerPass) that contains nine datasets captured with different sensors. We analyzed the effects of different sensors and found that cross-sensor matching performance deteriorates when different sensors are used for enrollment and verification. In view of our analysis, we propose future research directions for this problem.

  15. Neutron-beam-shaping assembly for boron neutron-capture therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zaidi, L.; Kashaeva, E. A.; Lezhnin, S. I.

    A neutron-beam-shaping assembly consisting of a moderator, a reflector, and an absorber is used to form a therapeutic neutron beam for the boron neutron-capture therapy of malignant tumors at accelerator neutron sources. A new structure of the moderator and reflector is proposed in the present article, and the results of a numerical simulation of the neutron spectrum and of the absorbed dose in a modified Snyder head phantom are presented. The application of a composite moderator and of a composite reflector and the implementation of neutron production at the proton energy of 2.3MeV are shown to permit obtaining a high-qualitymore » therapeutic neutron beam.« less

  16. Monte Carlo calculations of lung dose in ORNL phantom for boron neutron capture therapy.

    PubMed

    Krstic, D; Markovic, V M; Jovanovic, Z; Milenkovic, B; Nikezic, D; Atanackovic, J

    2014-10-01

    Monte Carlo simulations were performed to evaluate dose for possible treatment of cancers by boron neutron capture therapy (BNCT). The computational model of male Oak Ridge National Laboratory (ORNL) phantom was used to simulate tumours in the lung. Calculations have been performed by means of the MCNP5/X code. In this simulation, two opposite neutron beams were considered, in order to obtain uniform neutron flux distribution inside the lung. The obtained results indicate that the lung cancer could be treated by BNCT under the assumptions of calculations. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Single step synthesis of nanostructured boron nitride for boron neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Singh, Bikramjeet; Singh, Paviter; Kumar, Manjeet; Thakur, Anup; Kumar, Akshay

    2015-05-01

    Nanostructured Boron Nitride (BN) has been successfully synthesized by carbo-thermic reduction of Boric Acid (H3BO3). This method is a relatively low temperature synthesis route and it can be used for large scale production of nanostructured BN. The synthesized nanoparticles have been characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) and differential thermal analyzer (DTA). XRD analysis confirmed the formation of single phase nanostructured Boron Nitride. SEM analysis showed that the particles are spherical in shape. DTA analysis showed that the phase is stable upto 900 °C and the material can be used for high temperature applications as well boron neutron capture therapy (BNCT).

  18. Pilot clinical study of boron neutron capture therapy for recurrent hepatic cancer involving the intra-arterial injection of a (10)BSH-containing WOW emulsion.

    PubMed

    Yanagie, Hironobu; Higashi, Syushi; Seguchi, Koji; Ikushima, Ichiro; Fujihara, Mituteru; Nonaka, Yasumasa; Oyama, Kazuyuki; Maruyama, Syoji; Hatae, Ryo; Suzuki, Minoru; Masunaga, Shin-ichiro; Kinashi, Tomoko; Sakurai, Yoshinori; Tanaka, Hiroki; Kondo, Natsuko; Narabayashi, Masaru; Kajiyama, Tetsuya; Maruhashi, Akira; Ono, Koji; Nakajima, Jun; Ono, Minoru; Takahashi, Hiroyuki; Eriguchi, Masazumi

    2014-06-01

    A 63-year-old man with multiple HCC in his left liver lobe was enrolled as the first patient in a pilot study of boron neutron capture therapy (BNCT) involving the selective intra-arterial infusion of a (10)BSH-containing water-in-oil-in-water emulsion ((10)BSH-WOW). The size of the tumorous region remained stable during the 3 months after the BNCT. No adverse effects of the BNCT were observed. The present results show that (10)BSH-WOW can be used as novel intra-arterial boron carriers during BNCT for HCC. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Measurement of in-phantom neutron flux and gamma dose in Tehran research reactor boron neutron capture therapy beam line.

    PubMed

    Bavarnegin, Elham; Sadremomtaz, Alireza; Khalafi, Hossein; Kasesaz, Yaser

    2016-01-01

    Determination of in-phantom quality factors of Tehran research reactor (TRR) boron neutron capture therapy (BNCT) beam. The doses from thermal neutron reactions with 14N and 10B are calculated by kinetic energy released per unit mass approach, after measuring thermal neutron flux using neutron activation technique. Gamma dose is measured using TLD-700 dosimeter. Different dose components have been measured in a head phantom which has been designed and constructed for BNCT purpose in TRR. Different in-phantom beam quality factors have also been determined. This study demonstrates that the TRR BNCT beam line has potential for treatment of superficial tumors.

  20. Individual heterogeneity and identifiability in capture-recapture models

    USGS Publications Warehouse

    Link, W.A.

    2004-01-01

    Individual heterogeneity in detection probabilities is a far more serious problem for capture-recapture modeling than has previously been recognized. In this note, I illustrate that population size is not an identifiable parameter under the general closed population mark-recapture model Mh. The problem of identifiability is obvious if the population includes individuals with pi = 0, but persists even when it is assumed that individual detection probabilities are bounded away from zero. Identifiability may be attained within parametric families of distributions for pi, but not among parametric families of distributions. Consequently, in the presence of individual heterogeneity in detection probability, capture-recapture analysis is strongly model dependent.

  1. Synthesis and biological evaluation of new BSH-conjugated chlorin derivatives as agents for both photodynamic therapy and boron neutron capture therapy of cancer.

    PubMed

    Asano, Ryuji; Nagami, Amon; Fukumoto, Yuki; Miura, Kaori; Yazama, Futoshi; Ito, Hideyuki; Sakata, Isao; Tai, Akihiro

    2014-11-01

    New disodium mercaptoundecahydro-closo-dodecaborate (BSH)-conjugated chlorin derivatives 11, 12, 16 and 20 as agents for both photodynamic therapy (PDT) and boron neutron capture therapy (BNCT) of cancer were synthesized. The in vivo biodistribution and clearance of 11, 12, 16 and 20 were investigated in tumor-bearing mice. Compounds 12 and 16 showed good tumor-selective accumulation among the four derivatives. The time to maximum accumulation of compound 16 in tumor tissue was one-fourth of that of compound 12, and clearance from normal tissues of compound 16 was similar to that of compound 12. The in vivo therapeutic efficacy of PDT using 16, which has twice as many boron atoms as 12, was evaluated by measuring tumor growth rates in tumor-bearing mice with 660 nm light-emitting diode irradiation at 6h after injection of 16. Tumor growth was significantly inhibited by PDT using 16. These results suggested that 16 is a good candidate for both PDT and BNCT of cancer. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Where biomedicalisation and magic meet: Therapeutic innovations of elite sports injury in British professional football and cycling.

    PubMed

    Faulkner, Alex; McNamee, Michael; Coveney, Catherine; Gabe, Jonathan

    2017-04-01

    Injury is a conspicuous feature of the practice and public spectacle of contemporary elite sports. The paper argues that the 'biomedicalisation' thesis (medico-industrial nexus, techno-scientific drivers, medical optimisation, biologisation, the rise of evidence and health surveillance) goes some way to capturing the use in elite sports injury of some highly specialised mainstream therapies and some highly maverick biological therapies, which are described. Nevertheless, these main strands of biomedicalisation do not capture the full range of these phenomena in the contexts of sports medicine and athletes' practices in accessing innovative, controversial therapies. Drawing on multi-method qualitative research on top-level professional football and cycling in the UK, 2014-2016, we argue that concepts of 'magic' and faith-based healing, mediated by notions of networking behaviour and referral systems, furnish a fuller explanation. We touch on the concept of 'medical pluralism', concluding that this should be revised in order to take account of belief-based access to innovative bio-therapies amongst elite sportspeople and organisations. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Analysis of MCNP simulated gamma spectra of CdTe detectors for boron neutron capture therapy.

    PubMed

    Winkler, Alexander; Koivunoro, Hanna; Savolainen, Sauli

    2017-06-01

    The next step in the boron neutron capture therapy (BNCT) is the real time imaging of the boron concentration in healthy and tumor tissue. Monte Carlo simulations are employed to predict the detector response required to realize single-photon emission computed tomography in BNCT, but have failed to correctly resemble measured data for cadmium telluride detectors. In this study we have tested the gamma production cross-section data tables of commonly used libraries in the Monte Carlo code MCNP in comparison to measurements. The cross section data table TENDL-2008-ACE is reproducing measured data best, whilst the commonly used ENDL92 and other studied libraries do not include correct tables for the gamma production from the cadmium neutron capture reaction that is occurring inside the detector. Furthermore, we have discussed the size of the annihilation peaks of spectra obtained by cadmium telluride and germanium detectors. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. The efficacy of problem solving therapy to reduce post stroke emotional distress in younger (18-65) stroke survivors.

    PubMed

    Chalmers, Charlotte; Leathem, Janet; Bennett, Simon; McNaughton, Harry; Mahawish, Karim

    2017-11-26

    To investigate the efficacy of problem solving therapy for reducing the emotional distress experienced by younger stroke survivors. A non-randomized waitlist controlled design was used to compare outcome measures for the treatment group and a waitlist control group at baseline and post-waitlist/post-therapy. After the waitlist group received problem solving therapy an analysis was completed on the pooled outcome measures at baseline, post-treatment, and three-month follow-up. Changes on outcome measures between baseline and post-treatment (n = 13) were not significantly different between the two groups, treatment (n = 13), and the waitlist control group (n = 16) (between-subject design). The pooled data (n = 28) indicated that receiving problem solving therapy significantly reduced participants levels of depression and anxiety and increased quality of life levels from baseline to follow up (within-subject design), however, methodological limitations, such as the lack of a control group reduce the validity of this finding. The between-subject results suggest that there was no significant difference between those that received problem solving therapy and a waitlist control group between baseline and post-waitlist/post-therapy. The within-subject design suggests that problem solving therapy may be beneficial for younger stroke survivors when they are given some time to learn and implement the skills into their day to day life. However, additional research with a control group is required to investigate this further. This study provides limited evidence for the provision of support groups for younger stroke survivors post stroke, however, it remains unclear about what type of support this should be. Implications for Rehabilitation Problem solving therapy is no more effective for reducing post stroke distress than a wait-list control group. Problem solving therapy may be perceived as helpful and enjoyable by younger stroke survivors. Younger stroke survivors may use the skills learnt from problem solving therapy to solve problems in their day to day lives. Younger stroke survivors may benefit from age appropriate psychological support; however, future research is needed to determine what type of support this should be.

  5. Clinical trials for treating recurrent head and neck cancer with boron neutron capture therapy using the Tsing-Hua Open Pool Reactor.

    PubMed

    Wang, Ling-Wei; Liu, Yen-Wan Hsueh; Chou, Fong-In; Jiang, Shiang-Huei

    2018-06-19

    Head and neck (HN) cancer is an endemic disease in Taiwan, China. Locally recurrent HN cancer after full-dose irradiation poses a therapeutic challenge, and boron neutron capture therapy (BNCT) may be a solution that could provide durable local control with tolerable toxicity. The Tsing-Hua Open Pool Reactor (THOR) at National Tsing-Hua University in Hsin-Chu, provides a high-quality epithermal neutron source for basic and clinical BNCT research. Our first clinical trial, entitled "A phase I/II trial of boron neutron capture therapy for recurrent head and neck cancer at THOR", was carried out between 2010 and 2013. A total of 17 patients with 23 recurrent HN tumors who had received high-dose photon irradiation were enrolled in the study. The fructose complex of L-boronophenylalanine was used as a boron carrier, and a two-fraction BNCT treatment regimen at 28-day intervals was used for each patient. Toxicity was acceptable, and although the response rate was high (12/17), re-recurrence within or near the radiation site was common. To obtain better local control, another clinical trial entitled "A phase I/II trial of boron neutron capture therapy combined with image-guided intensity-modulated radiotherapy (IG-IMRT) for locally recurrent HN cancer" was initiated in 2014. The first administration of BNCT was performed according to our previous protocol, and IG-IMRT was initiated 28 days after BNCT. As of May 2017, seven patients have been treated with this combination. The treatment-related toxicity was similar to that previously observed with two BNCT applications. Three patients had a complete response, but locoregional recurrence was the major cause of failure despite initially good responses. Future clinical trials combining BNCT with other local or systemic treatments will be carried out for recurrent HN cancer patients at THOR.

  6. Our solution for fusion of simultaneusly acquired whole body scintigrams and optical images, as usesful tool in clinical practice in patients with differentiated thyroid carcinomas after radioiodine therapy. A useful tool in clinical practice.

    PubMed

    Matovic, Milovan; Jankovic, Milica; Barjaktarovic, Marko; Jeremic, Marija

    2017-01-01

    After radioiodine therapy of differentiated thyroid cancer (DTC) patients, whole body scintigraphy (WBS) is standard procedure before releasing the patient from the hospital. A common problem is the precise localization of regions where the iod-avide tissue is located. Sometimes is practically impossible to perform precise topographic localization of such regions. In order to face this problem, we have developed a low-cost Vision-Fusion system for web-camera image acquisition simultaneously with routine scintigraphic whole body acquisition including the algorithm for fusion of images given from both cameras. For image acquisition in the gamma part of the spectra we used e.cam dual head gamma camera (Siemens, Erlangen, Germany) in WBS modality, with matrix size of 256×1024 pixels and bed speed of 6cm/min, equipped with high energy collimator. For optical image acquisition in visible part of spectra we have used web-camera model C905 (Logitech, USA) with Carl Zeiss® optics, native resolution 1600×1200 pixels, 34 o field of view, 30g weight, with autofocus option turned "off" and auto white balance turned "on". Web camera is connected to upper head of gamma camera (GC) by a holder of lightweight aluminum rod and a plexiglas adapter. Our own Vision-Fusion software for image acquisition and coregistration was developed using NI LabVIEW programming environment 2015 (National Instruments, Texas, USA) and two additional LabVIEW modules: NI Vision Acquisition Software (VAS) and NI Vision Development Module (VDM). Vision acquisition software enables communication and control between laptop computer and web-camera. Vision development module is image processing library used for image preprocessing and fusion. Software starts the web-camera image acquisition before starting image acquisition on GC and stops it when GC completes the acquisition. Web-camera is in continuous acquisition mode with frame rate f depending on speed of patient bed movement v (f=v/∆ cm , where ∆ cm is a displacement step that can be changed in Settings option of Vision-Fusion software; by default, ∆ cm is set to 1cm corresponding to ∆ p =15 pixels). All images captured while patient's bed is moving are processed. Movement of patient's bed is checked using cross-correlation of two successive images. After each image capturing, algorithm extracts the central region of interest (ROI) of the image, with the same width as captured image (1600 pixels) and the height that is equal to the ∆ p displacement in pixels. All extracted central ROI are placed next to each other in the overall whole-body image. Stacking of narrow central ROI introduces negligible distortion in the overall whole-body image. The first step for fusion of the scintigram and the optical image was determination of spatial transformation between them. We have made an experiment with two markers (point radioactivity sources of 99m Tc pertechnetate 1MBq) visible in both images (WBS and optical) to find transformation of coordinates between images. The distance between point markers is used for spatial coregistration of the gamma and optical images. At the end of coregistration process, gamma image is rescaled in spatial domain and added to the optical image (green or red channel, amplification changeable from user interface). We tested our system for 10 patients with DTC who received radioiodine therapy (8 women and two men, with average age of 50.10±12.26 years). Five patients received 5.55Gbq, three 3.70GBq and two 1.85GBq. Whole-body scintigraphy and optical image acquisition were performed 72 hours after application of radioiodine therapy. Based on our first results during clinical testing of our system, we can conclude that our system can improve diagnostic possibility of whole body scintigraphy to detect thyroid remnant tissue in patients with DTC after radioiodine therapy.

  7. Conceptual model and economic experiments to explain nonpersistence and enable mechanism designs fostering behavioral change.

    PubMed

    Djawadi, Behnud Mir; Fahr, René; Turk, Florian

    2014-12-01

    Medical nonpersistence is a worldwide problem of striking magnitude. Although many fields of studies including epidemiology, sociology, and psychology try to identify determinants for medical nonpersistence, comprehensive research to explain medical nonpersistence from an economics perspective is rather scarce. The aim of the study was to develop a conceptual framework that augments standard economic choice theory with psychological concepts of behavioral economics to understand how patients' preferences for discontinuing with therapy arise over the course of the medical treatment. The availability of such a framework allows the targeted design of mechanisms for intervention strategies. Our conceptual framework models the patient as an active economic agent who evaluates the benefits and costs for continuing with therapy. We argue that a combination of loss aversion and mental accounting operations explains why patients discontinue with therapy at a specific point in time. We designed a randomized laboratory economic experiment with a student subject pool to investigate the behavioral predictions. Subjects continue with therapy as long as experienced utility losses have to be compensated. As soon as previous losses are evened out, subjects perceive the marginal benefit of persistence lower than in the beginning of the treatment. Consequently, subjects start to discontinue with therapy. Our results highlight that concepts of behavioral economics capture the dynamic structure of medical nonpersistence better than does standard economic choice theory. We recommend that behavioral economics should be a mandatory part of the development of possible intervention strategies aimed at improving patients' compliance and persistence behavior. Copyright © 2014 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  8. Neutron capture therapy with deep tissue penetration using capillary neutron focusing

    DOEpatents

    Peurrung, Anthony J.

    1997-01-01

    An improved method for delivering thermal neutrons to a subsurface cancer or tumor which has been first doped with a dopant having a high cross section for neutron capture. The improvement is the use of a guide tube in cooperation with a capillary neutron focusing apparatus, or neutron focusing lens, for directing neutrons to the tumor, and thereby avoiding damage to surrounding tissue.

  9. Experimental and Simulated Characterization of a Beam Shaping Assembly for Accelerator- Based Boron Neutron Capture Therapy (AB-BNCT)

    NASA Astrophysics Data System (ADS)

    Burlon, Alejandro A.; Girola, Santiago; Valda, Alejandro A.; Minsky, Daniel M.; Kreiner, Andrés J.

    2010-08-01

    In the frame of the construction of a Tandem Electrostatic Quadrupole Accelerator facility devoted to the Accelerator-Based Boron Neutron Capture Therapy, a Beam Shaping Assembly has been characterized by means of Monte-Carlo simulations and measurements. The neutrons were generated via the 7Li(p, n)7Be reaction by irradiating a thick LiF target with a 2.3 MeV proton beam delivered by the TANDAR accelerator at CNEA. The emerging neutron flux was measured by means of activation foils while the beam quality and directionality was evaluated by means of Monte Carlo simulations. The parameters show compliance with those suggested by IAEA. Finally, an improvement adding a beam collimator has been evaluated.

  10. Single step synthesis of nanostructured boron nitride for boron neutron capture therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Bikramjeet; Singh, Paviter; Kumar, Akshay, E-mail: akshaykumar.tiet@gmail.com

    2015-05-15

    Nanostructured Boron Nitride (BN) has been successfully synthesized by carbo-thermic reduction of Boric Acid (H{sub 3}BO{sub 3}). This method is a relatively low temperature synthesis route and it can be used for large scale production of nanostructured BN. The synthesized nanoparticles have been characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) and differential thermal analyzer (DTA). XRD analysis confirmed the formation of single phase nanostructured Boron Nitride. SEM analysis showed that the particles are spherical in shape. DTA analysis showed that the phase is stable upto 900 °C and the material can be used for high temperature applications asmore » well boron neutron capture therapy (BNCT)« less

  11. Optimal moderator materials at various proton energies considering photon dose rate after irradiation for an accelerator-driven ⁹Be(p, n) boron neutron capture therapy neutron source.

    PubMed

    Hashimoto, Y; Hiraga, F; Kiyanagi, Y

    2015-12-01

    We evaluated the accelerator beam power and the neutron-induced radioactivity of (9)Be(p, n) boron neutron capture therapy (BNCT) neutron sources having a MgF2, CaF2, or AlF3 moderator and driven by protons with energy from 8 MeV to 30 MeV. The optimal moderator materials were found to be MgF2 for proton energies less than 10 MeV because of lower required accelerator beam power and CaF2 for higher proton energies because of lower photon dose rate at the treatment position after neutron irradiation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Capture orbits around asteroids by hitting zero-velocity curves

    NASA Astrophysics Data System (ADS)

    Wang, Wei; Yang, Hongwei; Zhang, Wei; Ma, Guangfu

    2017-12-01

    The problem of capturing a spacecraft from a heliocentric orbit into a high parking orbit around binary asteroids is investigated in the current study. To reduce the braking Δ V, a new capture strategy takes advantage of the three-body gravity of the binary asteroid to lower the inertial energy before applying the Δ V. The framework of the circular restricted three-body problem (CR3BP) is employed for the binary asteroid system. The proposed capture strategy is based on the mechanism by which inertial energy can be decreased sharply near zero-velocity curves (ZVCs). The strategy has two steps, namely, hitting the target ZVC and raising the periapsis by a small Δ V at the apoapsis. By hitting the target ZVC, the positive inertial energy decreases and becomes negative. Using a small Δ V, the spacecraft inserts into a bounded orbit around the asteroid. In addition, a rotating mass dipole model is employed for elongated asteroids, which leads to dynamics similar to that of the CR3BP. With this approach, the proposed capture strategy can be applied to elongated asteroids. Numerical simulations validate that the proposed capture strategy is applicable for the binary asteroid 90 Antiope and the elongated asteroid 216 Kleopatra.

  13. Real-World Switching to Riociguat: Management and Practicalities in Patients with PAH and CTEPH.

    PubMed

    Gall, Henning; Vachiéry, Jean-Luc; Tanabe, Nobuhiro; Halank, Michael; Orozco-Levi, Mauricio; Mielniczuk, Lisa; Chang, MiKyung; Vogtländer, Kai; Grünig, Ekkehard

    2018-06-01

    A proportion of patients with pulmonary arterial hypertension (PAH) and chronic thromboembolic pulmonary hypertension (CTEPH) do not achieve treatment goals or experience side effects on their current therapy. In such cases, switching patients to a new drug while discontinuing the first may be a viable and appropriate treatment option. CAPTURE was designed to investigate how physicians manage the switching of patients to riociguat in real-world clinical practice. Observations from the study were used to assess whether recommendations in the riociguat prescribing information are reflected in clinical practice. CAPTURE was an international, multicenter, uncontrolled, retrospective chart review that collected data from patients with PAH or inoperable or persistent/recurrent CTEPH who switched to riociguat from another pulmonary hypertension (PH)-targeted medical therapy. The primary objective of the study was to understand the procedure undertaken in real-world clinical practice for patients switching to riociguat. Of 127 patients screened, 125 were enrolled in CAPTURE. The majority of patients switched from a phosphodiesterase type 5 inhibitor (PDE5i) to riociguat and the most common reason for switching was lack of efficacy. Physicians were already using the recommended treatment-free period when switching patients to riociguat from sildenafil, but a slightly longer period than recommended for tadalafil. In line with the contraindication, the majority of patients did not receive riociguat and PDE5i therapy concomitantly. Physicians also followed the recommended dose-adjustment procedure for riociguat. Switching to riociguat from another PH-targeted therapy may be feasible in real-world clinical practice in the context of the current recommendations.

  14. From the Nano- to the Macroscale - Bridging Scales for the Moving Contact Line Problem

    NASA Astrophysics Data System (ADS)

    Nold, Andreas; Sibley, David; Goddard, Benjamin; Kalliadasis, Serafim; Complex Multiscale Systems Team

    2016-11-01

    The moving contact line problem remains an unsolved fundamental problem in fluid mechanics. At the heart of the problem is its multiscale nature: a nanoscale region close to the solid boundary where the continuum hypothesis breaks down, must be resolved before effective macroscale parameters such as contact line friction and slip can be obtained. To capture nanoscale properties very close to the contact line and to establish a link to the macroscale behaviour, we employ classical density-functional theory (DFT), in combination with extended Navier-Stokes-like equations. Using simple models for viscosity and slip at the wall, we compare our computations with the Molecular Kinetic Theory, by extracting the contact line friction, depending on the imposed temperature of the fluid. A key fluid property captured by DFT is the fluid layering at the wall-fluid interface, which has a large effect on the shearing properties of a fluid. To capture this crucial property, we propose an anisotropic model for the viscosity, which also allows us to scrutinize the effect of fluid layering on contact line friction.

  15. Unresolved Problems by Shock Capturing: Taming the Overheating Problem

    NASA Technical Reports Server (NTRS)

    Liou, Meng-Sing

    2012-01-01

    The overheating problem, first observed by von Neumann [1] and later studied extensively by Noh [2] using both Eulerian and Lagrangian formulations, remains to be one of the unsolved problems by shock capturing. It is historically well known to occur when a flow is under compression, such as when a shock wave hits and reflects from a wall or when two streams collides with each other. The overheating phenomenon is also found numerically in a smooth flow undergoing rarefaction created by two streams receding from each other. This is in contrary to one s intuition expecting a decrease in internal energy. The excessive amount in the temperature increase does not reduce by refining the mesh size or increasing the order of accuracy. This study finds that the overheating in the receding flow correlates with the entropy generation. By requiring entropy preservation, the overheating is eliminated and the solution is grid convergent. The shock-capturing scheme, as being practiced today, gives rise to the entropy generation, which in turn causes the overheating. This assertion stands up to the convergence test.

  16. Modeling Thermally Driven Flow Problems with a Grid-Free Vortex Filament Scheme: Part 1

    DTIC Science & Technology

    2018-02-01

    provision has been made to include grid-free energy particles and thus a capability of capturing 2-way coupling between momentum and energy via barotropic...vorticity generation associated with thermal gradients. The validation studies have focused on natural convection following a release of energy into...a stagnant field and show that this new method is capable of capturing the correct physics of 3-D natural convection problems. vortex filament, energy

  17. Atmospheric inverse modeling via sparse reconstruction

    NASA Astrophysics Data System (ADS)

    Hase, Nils; Miller, Scot M.; Maaß, Peter; Notholt, Justus; Palm, Mathias; Warneke, Thorsten

    2017-10-01

    Many applications in atmospheric science involve ill-posed inverse problems. A crucial component of many inverse problems is the proper formulation of a priori knowledge about the unknown parameters. In most cases, this knowledge is expressed as a Gaussian prior. This formulation often performs well at capturing smoothed, large-scale processes but is often ill equipped to capture localized structures like large point sources or localized hot spots. Over the last decade, scientists from a diverse array of applied mathematics and engineering fields have developed sparse reconstruction techniques to identify localized structures. In this study, we present a new regularization approach for ill-posed inverse problems in atmospheric science. It is based on Tikhonov regularization with sparsity constraint and allows bounds on the parameters. We enforce sparsity using a dictionary representation system. We analyze its performance in an atmospheric inverse modeling scenario by estimating anthropogenic US methane (CH4) emissions from simulated atmospheric measurements. Different measures indicate that our sparse reconstruction approach is better able to capture large point sources or localized hot spots than other methods commonly used in atmospheric inversions. It captures the overall signal equally well but adds details on the grid scale. This feature can be of value for any inverse problem with point or spatially discrete sources. We show an example for source estimation of synthetic methane emissions from the Barnett shale formation.

  18. Integrative Problem-Centered Therapy: Toward the Synthesis of Family and Individual Psychotherapies.

    ERIC Educational Resources Information Center

    Pinsof, William M.

    1983-01-01

    Presents an overview of the Integrative Problem-Centered Therapy (IPCT) Model, and describes its core principles and premises, and basic methodological steps. The IPCT provides a technique for applying individual and family therapy and behavioral, communicational, and psychodynamic orientations to client problems. Its goal is to create efficient…

  19. The Effectiveness of Art Therapy in Reducing Internalizing and Externalizing Problems of Female Adolescents.

    PubMed

    Bazargan, Yasaman; Pakdaman, Shahla

    2016-01-01

    The internalizing and externalizing problems relating to childhood and adolescent have always been significant. Because there is special considerations in establishing communication with them and hence, the therapeutic methods for these problems must take into account these considerations. As establishing a therapeutic relationship is an important component of effective counseling, it seems that art therapy may help alleviate these problems. The purpose of this study is to determine the effectiveness of art therapy in reducing internalizing and externalizing problems of adolescent girls (14 - 18 years old). This is a semi-experimental study carried out in the form of a pre-test/post-test design with control group. The population of this study includes female students of Gole Laleh School of Art in district 3 of Tehran, Iran, out of which 30 students with internalizing problems and 30 individuals with externalizing problems were selected through targeted sampling. Students were randomly assigned to control and experimental groups. Experimental groups participated in 6 painting sessions designed based on Art therapy theories and previous studies. The material used for diagnosis of the problems in posttest and pretest was an Achenbach self-assessment form. Data were analyzed using a mixed analysis of variance (ANOVA). Our results showed that Art therapy significantly reduced internalizing problems (F = 17.61, P < 0.001); however, its effect in reducing externalizing problems was not significant (F = 3.93, P = 0.06). Art therapy as a practical therapeutic method can be used to improve internalizing problems. To reduce externalizing problems, more sessions may be needed. Thus, future studies are required to insure these findings.

  20. Using the critical incident technique to define a minimal data set for requirements elicitation in public health.

    PubMed

    Olvingson, Christina; Hallberg, Niklas; Timpka, Toomas; Greenes, Robert A

    2002-12-18

    The introduction of computer-based information systems (ISs) in public health provides enhanced possibilities for service improvements and hence also for improvement of the population's health. Not least, new communication systems can help in the socialization and integration process needed between the different professions and geographical regions. Therefore, development of ISs that truly support public health practices require that technical, cognitive, and social issues be taken into consideration. A notable problem is to capture 'voices' of all potential users, i.e., the viewpoints of different public health practitioners. Failing to capture these voices will result in inefficient or even useless systems. The aim of this study is to develop a minimal data set for capturing users' voices on problems experienced by public health professionals in their daily work and opinions about how these problems can be solved. The issues of concern thus captured can be used both as the basis for formulating the requirements of ISs for public health professionals and to create an understanding of the use context. Further, the data can help in directing the design to the features most important for the users.

  1. Neutron capture therapy with deep tissue penetration using capillary neutron focusing

    DOEpatents

    Peurrung, A.J.

    1997-08-19

    An improved method is disclosed for delivering thermal neutrons to a subsurface cancer or tumor which has been first doped with a dopant having a high cross section for neutron capture. The improvement is the use of a guide tube in cooperation with a capillary neutron focusing apparatus, or neutron focusing lens, for directing neutrons to the tumor, and thereby avoiding damage to surrounding tissue. 1 fig.

  2. Characteristics of a heavy water photoneutron source in boron neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Danial, Salehi; Dariush, Sardari; M. Salehi, Jozani

    2013-07-01

    Bremsstrahlung photon beams produced by medical linear accelerators are currently the most commonly used method of radiation therapy for cancerous tumors. Photons with energies greater than 8-10 MeV potentially generate neutrons through photonuclear interactions in the accelerator's treatment head, patient's body, and treatment room ambient. Electrons impinging on a heavy target generate a cascade shower of bremsstrahlung photons, the energy spectrum of which shows an end point equal to the electron beam energy. By varying the target thickness, an optimum thickness exists for which, at the given electron energy, maximum photon flux is achievable. If a source of high-energy photons i.e. bremsstrahlung, is conveniently directed to a suitable D2O target, a novel approach for production of an acceptable flux of filterable photoneturons for boron neutron capture therapy (BNCT) application is possible. This study consists of two parts. 1. Comparison and assessment of deuterium photonuclear cross section data. 2. Evaluation of the heavy water photonuclear source.

  3. Boron Neutron Capture Therapy (BNCT) Dose Calculation using Geometrical Factors Spherical Interface for Glioblastoma Multiforme

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zasneda, Sabriani; Widita, Rena

    2010-06-22

    Boron Neutron Capture Therapy (BNCT) is a cancer therapy by utilizing thermal neutron to produce alpha particles and lithium nuclei. The superiority of BNCT is that the radiation effects could be limited only for the tumor cells. BNCT radiation dose depends on the distribution of boron in the tumor. Absorbed dose to the cells from the reaction 10B (n, {alpha}) 7Li was calculated near interface medium containing boron and boron-free region. The method considers the contribution of the alpha particle and recoiled lithium particle to the absorbed dose and the variation of Linear Energy Transfer (LET) charged particles energy. Geometricalmore » factor data of boron distribution for the spherical surface is used to calculate the energy absorbed in the tumor cells, brain and scalp for case Glioblastoma Multiforme. The result shows that the optimal dose in tumor is obtained for boron concentrations of 22.1 mg {sup 10}B/g blood.« less

  4. Advances in boron neutron capture therapy (BNCT) at kyoto university - From reactor-based BNCT to accelerator-based BNCT

    NASA Astrophysics Data System (ADS)

    Sakurai, Yoshinori; Tanaka, Hiroki; Takata, Takushi; Fujimoto, Nozomi; Suzuki, Minoru; Masunaga, Shinichiro; Kinashi, Yuko; Kondo, Natsuko; Narabayashi, Masaru; Nakagawa, Yosuke; Watanabe, Tsubasa; Ono, Koji; Maruhashi, Akira

    2015-07-01

    At the Kyoto University Research Reactor Institute (KURRI), a clinical study of boron neutron capture therapy (BNCT) using a neutron irradiation facility installed at the research nuclear reactor has been regularly performed since February 1990. As of November 2014, 510 clinical irradiations were carried out using the reactor-based system. The world's first accelerator-based neutron irradiation system for BNCT clinical irradiation was completed at this institute in early 2009, and the clinical trial using this system was started in 2012. A shift of BCNT from special particle therapy to a general one is now in progress. To promote and support this shift, improvements to the irradiation system, as well as its preparation, and improvements in the physical engineering and the medical physics processes, such as dosimetry systems and quality assurance programs, must be considered. The recent advances in BNCT at KURRI are reported here with a focus on physical engineering and medical physics topics.

  5. A Delphi survey of the views of adult male patients with personality disorders on psychoeducation and social problem-solving therapy.

    PubMed

    McMurran, Mary; Wilmington, Rebekah

    2007-01-01

    Psychoeducation and social problem-solving therapy are treatment components that work well in tandem for offenders with personality disorders, hence it is worthwhile to maintain and improve their effectiveness. The aim was to seek patients' views of these therapies to contribute to their development. A Delphi survey was conducted with all 12 male inpatients of a personality disorder hospital treatment unit. Round 1 produced 30 statements for psychoeducation and 59 for social problem-solving therapy to be rated in Round 2. There was consensus at a level of 70% for all items. Both psychoeducation and social problem-solving therapies were viewed as useful by these patients. The men also suggested improvements in psychoeducation, including minimizing the delay between assessment and feedback, provision of reference material, preparation for the work and support afterwards. Areas identified for improvement in social problem-solving therapy included more frequent review of progress, greater consistency of delivery, eliciting problems more effectively, providing reference material, supporting patients in group work, and the development of an advanced therapy. A Delphi approach to evaluation of therapies with the people receiving them is not only feasible but seems to offer a practical way of making useful clinical adjustments to the work. Further research with larger samples might usefully focus on whether such an approach enhances treatment compliance. 2007 John Wiley & Sons, Ltd

  6. High Dynamic Range Digital Imaging of Spacecraft

    NASA Technical Reports Server (NTRS)

    Karr, Brian A.; Chalmers, Alan; Debattista, Kurt

    2014-01-01

    The ability to capture engineering imagery with a wide degree of dynamic range during rocket launches is critical for post launch processing and analysis [USC03, NNC86]. Rocket launches often present an extreme range of lightness, particularly during night launches. Night launches present a two-fold problem: capturing detail of the vehicle and scene that is masked by darkness, while also capturing detail in the engine plume.

  7. Subcellular SIMS imaging of gadolinium isotopes in human glioblastoma cells treated with a gadolinium containing MRI agent

    NASA Astrophysics Data System (ADS)

    Smith, Duane R.; Lorey, Daniel R.; Chandra, Subhash

    2004-06-01

    Neutron capture therapy is an experimental binary radiotherapeutic modality for the treatment of brain tumors such as glioblastoma multiforme. Recently, neutron capture therapy with gadolinium-157 has gained attention, and techniques for studying the subcellular distribution of gadolinium-157 are needed. In this preliminary study, we have been able to image the subcellular distribution of gadolinium-157, as well as the other six naturally abundant isotopes of gadolinium, with SIMS ion microscopy. T98G human glioblastoma cells were treated for 24 h with 25 mg/ml of the metal ion complex diethylenetriaminepentaacetic acid Gd(III) dihydrogen salt hydrate (Gd-DTPA). Gd-DTPA is a contrast enhancing agent used for MRI of brain tumors, blood-brain barrier impairment, diseases of the central nervous system, etc. A highly heterogeneous subcellular distribution was observed for gadolinium-157. The nuclei in each cell were distinctly lower in gadolinium-157 than in the cytoplasm. Even within the cytoplasm the gadolinium-157 was heterogeneously distributed. The other six naturally abundant isotopes of gadolinium were imaged from the same cells and exhibited a subcellular distribution consistent with that observed for gadolinium-157. These observations indicate that SIMS ion microscopy may be a viable approach for subcellular studies of gadolinium containing neutron capture therapy drugs and may even play a major role in the development and validation of new gadolinium contrast enhancing agents for diagnostic MRI applications.

  8. Outcomes of Treatment Targeting Syntax Production in People with Broca's-Type Aphasia: Evidence from Psycholinguistic Assessment Tasks and Everyday Conversation

    ERIC Educational Resources Information Center

    Carragher, Marcella; Sage, Karen; Conroy, Paul

    2015-01-01

    Background: Capturing evidence of the effects of therapy within everyday communication is the holy grail of aphasia treatment design and evaluation. Whilst impaired sentence production is a predominant symptom of Broca's-type aphasia, the effects of sentence production therapy on everyday conversation have not been investigated. Given the…

  9. Comparison between proton boron fusion therapy (PBFT) and boron neutron capture therapy (BNCT): a monte carlo study.

    PubMed

    Jung, Joo-Young; Yoon, Do-Kun; Barraclough, Brendan; Lee, Heui Chang; Suh, Tae Suk; Lu, Bo

    2017-06-13

    The aim of this study is to compare between proton boron fusion therapy (PBFT) and boron neutron capture therapy (BNCT) and to analyze dose escalation using a Monte Carlo simulation. We simulated a proton beam passing through the water with a boron uptake region (BUR) in MCNPX. To estimate the interaction between neutrons/protons and borons by the alpha particle, the simulation yielded with a variation of the center of the BUR location and proton energies. The variation and influence about the alpha particle were observed from the percent depth dose (PDD) and cross-plane dose profile of both the neutron and proton beams. The peak value of the maximum dose level when the boron particle was accurately labeled at the region was 192.4% among the energies. In all, we confirmed that prompt gamma rays of 478 keV and 719 keV were generated by the nuclear reactions in PBFT and BNCT, respectively. We validated the dramatic effectiveness of the alpha particle, especially in PBFT. The utility of PBFT was verified using the simulation and it has a potential for application in radiotherapy.

  10. Therapeutic efficacy for hepatocellular carcinoma by boric acid-mediated boron neutron capture therapy in a rat model.

    PubMed

    Lin, Sy-Yu; Lin, Chen-Jou; Liao, Jiunn-Wang; Peir, Jinn-Jer; Chen, Wei-Lin; Chi, Chin-Wen; Lin, Yung-Chang; Liu, Yu-Ming; Chou, Fong-In

    2013-11-01

    Hepatocellular carcinoma (HCC) is a common malignant tumor with poor prognosis. Boron neutron capture therapy (BNCT) may provide an alternative therapy for HCC. This study investigated the therapeutic efficacy of boric acid (BA)-mediated BNCT for HCC in a rat model. The pharmacokinetic and biodistribution of BA in N1S1 tumor-bearing rats were analyzed. Rats were injected with 25 mg B/kg body weight via tail veins before neutron irradiation at the Tsing Hua Open-pool Reactor, and the efficacy of BNCT was evaluated from the tumor size, tumor blood flow, and biochemical analyses. HCC-bearing rats administered BNCT showed reductions in tumor size on ultrasound imaging, as well as an obvious reduction in the distribution of tumor blood flow. The lesion located in livers had disappeared on the 80th day after BNCT; a recovery of values to normal levels was also recorded. BA-mediated BNCT is a promising alternative for liver cancer therapy since the present study demonstrated the feasibility of curing a liver tumor and restoring liver function in rats. Efforts are underway to investigate the histopathological features and the detailed mechanisms of BA-mediated BNCT.

  11. Comparison between proton boron fusion therapy (PBFT) and boron neutron capture therapy (BNCT): a Monte Carlo study

    PubMed Central

    Barraclough, Brendan; Lee, Heui Chang; Suh, Tae Suk; Lu, Bo

    2017-01-01

    The aim of this study is to compare between proton boron fusion therapy (PBFT) and boron neutron capture therapy (BNCT) and to analyze dose escalation using a Monte Carlo simulation. We simulated a proton beam passing through the water with a boron uptake region (BUR) in MCNPX. To estimate the interaction between neutrons/protons and borons by the alpha particle, the simulation yielded with a variation of the center of the BUR location and proton energies. The variation and influence about the alpha particle were observed from the percent depth dose (PDD) and cross-plane dose profile of both the neutron and proton beams. The peak value of the maximum dose level when the boron particle was accurately labeled at the region was 192.4% among the energies. In all, we confirmed that prompt gamma rays of 478 keV and 719 keV were generated by the nuclear reactions in PBFT and BNCT, respectively. We validated the dramatic effectiveness of the alpha particle, especially in PBFT. The utility of PBFT was verified using the simulation and it has a potential for application in radiotherapy. PMID:28427153

  12. Internet-based cognitive behaviour therapy and physical exercise - Effects studied by automated telephone assessments in mental ill-health patients; a randomized controlled trial.

    PubMed

    Strid, Catharina; Andersson, Claes; Forsell, Yvonne; Öjehagen, Agneta; Lundh, Lars-Gunnar

    2016-11-01

    Mental ill-health has become a large health problem and it is important for caregivers to provide effective treatment alternatives. REGASSA is a randomized controlled study performed in primary care to study the effects of 12 weeks of Internet-based cognitive behaviour therapy (ICBT) and physical exercise (PE) compared with treatment as usual (TAU) in patients with mild-to-moderate mental ill-health. The present study aimed to examine the results of these treatment alternatives on psychological functioning, stress, and sleep disturbances. The study comprised 879 patients with mental ill-health taking part in the REGASSA study. Data were collected by Interactive Voice Response (IVR), a computerized, automated telephone technique. The treatments were compared at baseline, twice during treatment, at the end of treatment and at three follow-ups after treatment. Measures used were the Outcome Questionnaire-45, the short versions of the Perceived Stress Scale, and the Karolinska Sleep Questionnaire. Linear mixed models showed that the patients in ICBT and PE had better results than in TAU on psychological functioning and sleep disturbances, p < .001, with weak-to-moderate effect sizes. On stress there were no differences; all groups made improvements. Women had stronger effects than men. More patients recovered on psychological functioning (OQ-45) in ICBT and PE than in TAU. Internet-based cognitive behaviour therapy and PE proved to be effective treatment alternatives for patients with mild-to-moderate mental ill-health in improving psychological functioning, stress, and sleep disturbances and could be useful alternatives in primary care. Internet-based cognitive behaviour therapy and physical exercise proved to be effective treatment alternatives for mental ill-health patients in primary care. Automated techniques (Interactive Voice Response) could be useful for following treatment course in large groups of patients in the health care. It is important to use measures that capture different aspects of patients' health problems. The recruitment of participants was based on patients' interest and inclusion criteria which may have affect the generalizability. © 2016 The British Psychological Society.

  13. Clinical trial designs for testing biomarker-based personalized therapies

    PubMed Central

    Lai, Tze Leung; Lavori, Philip W; Shih, Mei-Chiung I; Sikic, Branimir I

    2014-01-01

    Background Advances in molecular therapeutics in the past decade have opened up new possibilities for treating cancer patients with personalized therapies, using biomarkers to determine which treatments are most likely to benefit them, but there are difficulties and unresolved issues in the development and validation of biomarker-based personalized therapies. We develop a new clinical trial design to address some of these issues. The goal is to capture the strengths of the frequentist and Bayesian approaches to address this problem in the recent literature and to circumvent their limitations. Methods We use generalized likelihood ratio tests of the intersection null and enriched strategy null hypotheses to derive a novel clinical trial design for the problem of advancing promising biomarker-guided strategies toward eventual validation. We also investigate the usefulness of adaptive randomization (AR) and futility stopping proposed in the recent literature. Results Simulation studies demonstrate the advantages of testing both the narrowly focused enriched strategy null hypothesis related to validating a proposed strategy and the intersection null hypothesis that can accommodate to a potentially successful strategy. AR and early termination of ineffective treatments offer increased probability of receiving the preferred treatment and better response rates for patients in the trial, at the expense of more complicated inference under small-to-moderate total sample sizes and some reduction in power. Limitations The binary response used in the development phase may not be a reliable indicator of treatment benefit on long-term clinical outcomes. In the proposed design, the biomarker-guided strategy (BGS) is not compared to ‘standard of care’, such as physician’s choice that may be informed by patient characteristics. Therefore, a positive result does not imply superiority of the BGS to ‘standard of care’. The proposed design and tests are valid asymptotically. Simulations are used to examine small-to-moderate sample properties. Conclusion Innovative clinical trial designs are needed to address the difficulties and issues in the development and validation of biomarker-based personalized therapies. The article shows the advantages of using likelihood inference and interim analysis to meet the challenges in the sample size needed and in the constantly evolving biomarker landscape and genomic and proteomic technologies. PMID:22397801

  14. Magnetically modified bioсells in constant magnetic field

    NASA Astrophysics Data System (ADS)

    Abramov, E. G.; Panina, L. K.; Kolikov, V. A.; Bogomolova, E. V.; Snetov, V. N.; Cherepkova, I. A.; Kiselev, A. A.

    2017-02-01

    Paper addresses the inverse problem in determining the area, where the external constant magnetic field captures the biological cells modified by the magnetic nanoparticles. Zero velocity isolines, in area where the modified cells are captured by the magnetic field were determined by numerical method for two locations of the magnet. The problem was solved taking into account the gravitational field, magnetic induction, density of medium, concentration and size of cells, and size and magnetization of nanoparticles attached to the cell. Increase in the number of the nanoparticles attached to the cell and decrease in the cell' size, enlarges the area, where the modified cells are captured and concentrated by the magnet. Solution is confirmed by the visible pattern formation of the modified cells Saccharomyces cerevisiae.

  15. Multi-Body Capture to Low-altitude Circular Orbits at Europa

    NASA Technical Reports Server (NTRS)

    Grebow, Daniel J.; Petropoulos, Anastassios E.; Finlayson, Paul A.

    2011-01-01

    For capture to a 200-km circular orbit around Europa, millions of different points along the orbit are simulated in the Jupiter-Europa Restricted 3-Body Problem. The transfers exist as members of families of trajectories, where certain families consistently outperform the others. The trajectories are not sensitive to changes in inclination for the final circular orbit. The top performing trajectories appear to follow the invariant manifolds of L2 Lyapunov orbits for capture into a retrograde orbit, and in some cases saving up to 40% of the from the patched 2-body problem. Transfers are attached to the current nominal mission for NASA's Jupiter-Europa Orbiter, where the total cost is roughly 100 m/s less than the baseline mission.

  16. Detection of vancomycin resistances in enterococci within 3 1/2 hours

    NASA Astrophysics Data System (ADS)

    Schröder, U. -Ch.; Beleites, C.; Assmann, C.; Glaser, U.; Hübner, U.; Pfister, W.; Fritzsche, W.; Popp, J.; Neugebauer, U.

    2015-02-01

    Vancomycin resistant enterococci (VRE) constitute a challenging problem in health care institutions worldwide. Novel methods to rapidly identify resistances are highly required to ensure an early start of tailored therapy and to prevent further spread of the bacteria. Here, a spectroscopy-based rapid test is presented that reveals resistances of enterococci towards vancomycin within 3.5 hours. Without any specific knowledge on the strain, VRE can be recognized with high accuracy in two different enterococci species. By means of dielectrophoresis, bacteria are directly captured from dilute suspensions, making sample preparation very easy. Raman spectroscopic analysis of the trapped bacteria over a time span of two hours in absence and presence of antibiotics reveals characteristic differences in the molecular response of sensitive as well as resistant Enterococcus faecalis and Enterococcus faecium. Furthermore, the spectroscopic fingerprints provide an indication on the mechanisms of induced resistance in VRE.

  17. The Fibromyalgia Impact Questionnaire (FIQ): a review of its development, current version, operating characteristics and uses.

    PubMed

    Bennett, R

    2005-01-01

    The Fibromyalgia Impact Questionnaire (FIQ) was developed in the late 1980s by clinicians at Oregon Health & Science University in an attempt to capture the total spectrum of problems related to fibromyalgia and the responses to therapy. It was first published in 1991 and since that time has been extensively used as an index of therapeutic efficacy. Overall, it has been shown to have a credible construct validity, reliable test-retest characteristics and a good sensitivity in demonstrating therapeutic change. The original questionnaire was modified in 1997 and 2002, to reflect ongoing experience with the instrument and to clarify the scoring system. The latest version of the FIQ can be found at the web site of the Oregon Fibromyalgia Foundation (www.myalgia.com/FIQ/FIQ). The FIQ has now been translated into eight languages, and the translated versions have shown operating characteristics similar to the English version.

  18. Boron Neutron Capture Therapy for Malignant Brain Tumors

    PubMed Central

    MIYATAKE, Shin-Ichi; KAWABATA, Shinji; HIRAMATSU, Ryo; KUROIWA, Toshihiko; SUZUKI, Minoru; KONDO, Natsuko; ONO, Koji

    2016-01-01

    Boron neutron capture therapy (BNCT) is a biochemically targeted radiotherapy based on the nuclear capture and fission reactions that occur when non-radioactive boron-10, which is a constituent of natural elemental boron, is irradiated with low energy thermal neutrons to yield high linear energy transfer alpha particles and recoiling lithium-7 nuclei. Therefore, BNCT enables the application of a high dose of particle radiation selectively to tumor cells in which boron-10 compound has been accumulated. We applied BNCT using nuclear reactors for 167 cases of malignant brain tumors, including recurrent malignant gliomas, newly diagnosed malignant gliomas, and recurrent high-grade meningiomas from January 2002 to May 2014. Here, we review the principle and history of BNCT. In addition, we introduce fluoride-18-labeled boronophenylalanine positron emission tomography and the clinical results of BNCT for the above-mentioned malignant brain tumors. Finally, we discuss the recent development of accelerators producing epithermal neutron beams. This development could provide an alternative to the current use of specially modified nuclear reactors as a neutron source, and could allow BNCT to be performed in a hospital setting. PMID:27250576

  19. Boron Neutron Capture Therapy for Malignant Brain Tumors.

    PubMed

    Miyatake, Shin-Ichi; Kawabata, Shinji; Hiramatsu, Ryo; Kuroiwa, Toshihiko; Suzuki, Minoru; Kondo, Natsuko; Ono, Koji

    2016-07-15

    Boron neutron capture therapy (BNCT) is a biochemically targeted radiotherapy based on the nuclear capture and fission reactions that occur when non-radioactive boron-10, which is a constituent of natural elemental boron, is irradiated with low energy thermal neutrons to yield high linear energy transfer alpha particles and recoiling lithium-7 nuclei. Therefore, BNCT enables the application of a high dose of particle radiation selectively to tumor cells in which boron-10 compound has been accumulated. We applied BNCT using nuclear reactors for 167 cases of malignant brain tumors, including recurrent malignant gliomas, newly diagnosed malignant gliomas, and recurrent high-grade meningiomas from January 2002 to May 2014. Here, we review the principle and history of BNCT. In addition, we introduce fluoride-18-labeled boronophenylalanine positron emission tomography and the clinical results of BNCT for the above-mentioned malignant brain tumors. Finally, we discuss the recent development of accelerators producing epithermal neutron beams. This development could provide an alternative to the current use of specially modified nuclear reactors as a neutron source, and could allow BNCT to be performed in a hospital setting.

  20. Study on High Speed Lithium Jet For Neutron Source of Boron Neutron Capture Therapy (BNCT)

    NASA Astrophysics Data System (ADS)

    Takahashi, Minoru; Kobayashi, Tooru; Zhang, Mingguang; Mák, Michael; Štefanica, Jirí; Dostál, Václav; Zhao, Wei

    The feasibility study of a liquid lithium type proton beam target was performed for the neutron source of the boron neutron capture therapy (BNCT). As the candidates of the liquid lithium target, a thin sheet jet and a thin film flow on a concave wall were chosen, and a lithium flow experiment was conducted to investigate the hydrodynamic stability of the targets. The surfaces of the jets and film flows with a thickness of 0.5 mm and a width of 50 mm were observed by means of photography. It has been found that a stable sheet jet and a stable film flow on a concave wall can be formed up to certain velocities by using a straight nozzle and a curved nozzle with the concave wall, respectively.

  1. Conceptual design project: Accelerator complex for nuclear physics studies and boron neutron capture therapy application at the Yerevan Physics Institute (YerPhI) Yerevan, Armenia

    NASA Astrophysics Data System (ADS)

    Avagyan, R. H.; Kerobyan, I. A.

    2015-07-01

    The final goal of the proposed project is the creation of a Complex of Accelerator Facilities at the Yerevan Physics Institute (CAF YerPhI) for nuclear physics basic researches, as well as for applied programs including boron neutron capture therapy (BNCT). The CAF will include the following facilities: Cyclotron C70, heavy material (uranium) target/ion source, mass-separator, LINAC1 (0.15-1.5 MeV/u) and LINAC2 (1.5-10 MeV/u). The delivered by C70 proton beams with energy 70 MeV will be used for investigations in the field of basic nuclear physics and with energy 30 MeV for use in applications.

  2. Boron neutron capture therapy (BNCT) in Finland: technological and physical prospects after 20 years of experiences.

    PubMed

    Savolainen, Sauli; Kortesniemi, Mika; Timonen, Marjut; Reijonen, Vappu; Kuusela, Linda; Uusi-Simola, Jouni; Salli, Eero; Koivunoro, Hanna; Seppälä, Tiina; Lönnroth, Nadja; Välimäki, Petteri; Hyvönen, Heini; Kotiluoto, Petri; Serén, Tom; Kuronen, Antti; Heikkinen, Sami; Kosunen, Antti; Auterinen, Iiro

    2013-05-01

    Boron Neutron Capture Therapy (BNCT) is a binary radiotherapy method developed to treat patients with certain malignant tumours. To date, over 300 treatments have been carried out at the Finnish BNCT facility in various on-going and past clinical trials. In this technical review, we discuss our research work in the field of medical physics to form the groundwork for the Finnish BNCT patient treatments, as well as the possibilities to further develop and optimize the method in the future. Accordingly, the following aspects are described: neutron sources, beam dosimetry, treatment planning, boron imaging and determination, and finally the possibilities to detect the efficacy and effects of BNCT on patients. Copyright © 2012 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  3. Hybrid data capture for monitoring patients on highly active antiretroviral therapy (HAART) in urban Botswana.

    PubMed

    Bussmann, Hermann; Wester, C William; Ndwapi, Ndwapi; Vanderwarker, Chris; Gaolathe, Tendani; Tirelo, Geoffrey; Avalos, Ava; Moffat, Howard; Marlink, Richard G

    2006-02-01

    Individual patient care and programme evaluation are pivotal for the success of antiretroviral treatment programmes in resource-limited countries. While computer-aided documentation and data storage are indispensable for any large programme, several important issues need to be addressed including which data are to be collected, who collects it and how it is entered into an electronic database. We describe a patient-monitoring approach, which uses patient encounter forms (in hybrid paper + electronic format) based on optical character recognition, piloted at Princess Marina Hospital in Gaborone, Botswana's first public highly active antiretroviral therapy (HAART) outpatient clinic. Our novel data capture approach collects "key" data for tracking patient and programme outcomes. It saves physician time and does not detract from clinical care.

  4. Hybrid data capture for monitoring patients on highly active antiretroviral therapy (HAART) in urban Botswana.

    PubMed Central

    Bussmann, Hermann; Wester, C. William; Ndwapi, Ndwapi; Vanderwarker, Chris; Gaolathe, Tendani; Tirelo, Geoffrey; Avalos, Ava; Moffat, Howard; Marlink, Richard G.

    2006-01-01

    Individual patient care and programme evaluation are pivotal for the success of antiretroviral treatment programmes in resource-limited countries. While computer-aided documentation and data storage are indispensable for any large programme, several important issues need to be addressed including which data are to be collected, who collects it and how it is entered into an electronic database. We describe a patient-monitoring approach, which uses patient encounter forms (in hybrid paper + electronic format) based on optical character recognition, piloted at Princess Marina Hospital in Gaborone, Botswana's first public highly active antiretroviral therapy (HAART) outpatient clinic. Our novel data capture approach collects "key" data for tracking patient and programme outcomes. It saves physician time and does not detract from clinical care. PMID:16501730

  5. Randomized Controlled Trial of Problem-Solving Therapy for Minor Depression in Home Care

    ERIC Educational Resources Information Center

    Gellis, Zvi D.; McGinty, Jean; Tierney, Lynda; Jordan, Cindy; Burton, Jean; Misener, Elizabeth

    2008-01-01

    Objective: Data are presented from a pilot research program initiated to develop, refine, and test the outcomes of problem-solving therapy that targets the needs of older adults with minor depression in home care settings. Method: A pilot randomized clinical trial compares the impact of problem-solving therapy for home care to treatment as usual…

  6. Findings of VA/DoD CPG on CAM Therapies for PTSD

    DTIC Science & Technology

    2011-01-26

    reaching than formal diagnoses – Suicide, adjustment problems, relationship & family problems, divorce, risky behaviors , etc. 2011 MHS Conference PTSD...restructuring; or stress inoculation training B •Imagery Rehearsal Therapy C •Patient Education •Psychodynamic Therapy • Hypnosis •Relaxation...Techniques •Group Therapy I •Family Therapy •Web-based CBT •Dialectical Behavioral 2011 MHS Conference PTSD Treatment: Pharmacotherapy SR

  7. How wilderness therapy works: an examination of the wilderness therapy process to treat adolescents with behavioral problems and addictions

    Treesearch

    Keith C. Russell; John C. Hendee; Dianne Phillips-Miller

    2000-01-01

    This paper summarizes findings from a detailed study of the processes employed by four leading wilderness therapy programs focusing on how wilderness therapy works, the kinds of behavioral problems to which it is commonly applied, expected outcomes and the role of wilderness in the intervention and treatment process (Russell, 1999). Wilderness therapy is an emerging...

  8. Design knowledge capture for a corporate memory facility

    NASA Technical Reports Server (NTRS)

    Boose, John H.; Shema, David B.; Bradshaw, Jeffrey M.

    1990-01-01

    Currently, much of the information regarding decision alternatives and trade-offs made in the course of a major program development effort is not represented or retained in a way that permits computer-based reasoning over the life cycle of the program. The loss of this information results in problems in tracing design alternatives to requirements, in assessing the impact of change in requirements, and in configuration management. To address these problems, the problem was studied of building an intelligent, active corporate memory facility which would provide for the capture of the requirements and standards of a program, analyze the design alternatives and trade-offs made over the program's lifetime, and examine relationships between requirements and design trade-offs. Early phases of the work have concentrated on design knowledge capture for the Space Station Freedom. Tools are demonstrated and extended which helps automate and document engineering trade studies, and another tool is being developed to help designers interactively explore design alternatives and constraints.

  9. On the problem of origin of periodic comets.

    NASA Astrophysics Data System (ADS)

    Guliev, A. S.

    The problem of origin of periodic comets is viewed under various aspects. A steady growth of the fraction of these comets in the overall population of comets is emphasized. The number of discovered periodic comets with small eccentricities and with the Jacobi constant close to 3 is also growing eventually. Comparison of maximum magnitudes of the same comets in different apparitions at the same elongations as well as the analysis of exhausted comets indicate that the age of these objects does not exceed 1000 years. Capture is considered as an efficient mechanism for preserving equilibrium over reasonable time intervals. The analysis of the data given by Everhart and the calculations of the evolution of cometary orbits reveal small efficiency of capture. Comparison of the number of well established capture cases with the corresponding time interval shows that the age of the system of periodic comets must be 17000 years within the framework of this mechanism. This is most unlikely. Secular variations in the distributions of semimajor axes, inclinations, longitudes of perihelia, eccentricities of orbits of periodic comets are analysed. On the average, the eccentricities tend to increase, but this conflicts with the capture mechanism. A conclusion is made that the concept of capture in its classical and modern versions is unable to solve the problem of the origin of periodic comets on the whole. Other, more effective sources and mechanisms seem to be also in operation in enlarging the cometary system.

  10. Ultra-fast electron capture by electrosterically-stabilized gold nanoparticles.

    PubMed

    Ghandi, Khashayar; Findlater, Alexander D; Mahimwalla, Zahid; MacNeil, Connor S; Awoonor-Williams, Ernest; Zahariev, Federico; Gordon, Mark S

    2015-07-21

    Ultra-fast pre-solvated electron capture has been observed for aqueous solutions of room-temperature ionic liquid (RTIL) surface-stabilized gold nanoparticles (AuNPs; ∼9 nm). The extraordinarily large inverse temperature dependent rate constants (k(e)∼ 5 × 10(14) M(-1) s(-1)) measured for the capture of electrons in solution suggest electron capture by the AuNP surface that is on the timescale of, and therefore in competition with, electron solvation and electron-cation recombination reactions. The observed electron transfer rates challenge the conventional notion that radiation induced biological damage would be enhanced in the presence of AuNPs. On the contrary, AuNPs stabilized by non-covalently bonded ligands demonstrate the potential to quench radiation-induced electrons, indicating potential applications in fields ranging from radiation therapy to heterogeneous catalysis.

  11. Cost effectiveness of treatment for alcohol problems: findings of the randomised UK alcohol treatment trial (UKATT).

    PubMed

    2005-09-10

    To compare the cost effectiveness of social behaviour and network therapy, a new treatment for alcohol problems, with that of the proved motivational enhancement therapy. Cost effectiveness analysis alongside a pragmatic randomised trial. Seven treatment sites around Birmingham, Cardiff, and Leeds. 742 clients with alcohol problems; 617 (83.2%) were interviewed at 12 months and full economic data were obtained on 608 (98.5% of 617). Main economic measures Quality adjusted life years (QALYs), costs of trial treatments, and consequences for public sector resources (health care, other alcohol treatment, social services, and criminal justice services). Both therapies saved about five times as much in expenditure on health, social, and criminal justice services as they cost. Neither net savings nor cost effectiveness differed significantly between the therapies, despite the average cost of social behaviour and network therapy (221 pounds sterling; 385 dollars; 320 euros) being significantly more than that of motivational enhancement therapy (129 pounds sterling). If a QALY were worth 30,000 pounds sterling, then the motivational therapy would have 58% chance of being more cost effective than the social therapy, and the social therapy would have 42% chance of being more cost effective than the motivational therapy. Participants reported highly significant reductions in drinking and associated problems and costs. The novel social behaviour and network therapy did not differ significantly in cost effectiveness from the proved motivational enhancement therapy.

  12. New teaching aid “Physical Methods of Medical Introscopy”

    NASA Astrophysics Data System (ADS)

    Ulin, S. E.

    2017-01-01

    Description of a new teaching aid, in which new methods of reconstruction of hidden images by means of nuclear magnetic resonance, X-gamma-ray, and ultrasonic tomography, is presented. The diagnostics and therapy methods of various oncological diseases with the use of medicine proton and ions beams, as well as neutron capture therapy, are considered. The new teaching aid is intended for senior students and postgraduates.

  13. Optimal Allocation of Sampling Effort in Depletion Surveys

    EPA Science Inventory

    We consider the problem of designing a depletion or removal survey as part of estimating animal abundance for populations with imperfect capture or detection rates. In a depletion survey, animals are captured from a given area, counted, and withheld from the population. This proc...

  14. Comparative study of high-resolution shock-capturing schemes for a real gas

    NASA Technical Reports Server (NTRS)

    Montagne, J.-L.; Yee, H. C.; Vinokur, M.

    1987-01-01

    Recently developed second-order explicit shock-capturing methods, in conjunction with generalized flux-vector splittings, and a generalized approximate Riemann solver for a real gas are studied. The comparisons are made on different one-dimensional Riemann (shock-tube) problems for equilibrium air with various ranges of Mach numbers, densities and pressures. Six different Riemann problems are considered. These tests provide a check on the validity of the generalized formulas, since theoretical prediction of their properties appears to be difficult because of the non-analytical form of the state equation. The numerical results in the supersonic and low-hypersonic regimes indicate that these produce good shock-capturing capability and that the shock resolution is only slightly affected by the state equation of equilibrium air. The difference in shock resolution between the various methods varies slightly from one Riemann problem to the other, but the overall accuracy is very similar. For the one-dimensional case, the relative efficiency in terms of operation count for the different methods is within 30%. The main difference between the methods lies in their versatility in being extended to multidimensional problems with efficient implicit solution procedures.

  15. Family Therapy and Psychosomatic Illness.

    ERIC Educational Resources Information Center

    Waring, Edward M.

    1980-01-01

    Reviews the use of family therapy in dealing with illnesses such as childhood diabetes, asthma, pain, and anorexia nervosa. Marital and family therapy may be effective in treating some psychosomatic problems. Family assessment is helpful in the management of all psychosomatic problems. (Author/JAC)

  16. Evaluation of a novel sodium borocaptate-containing unnatural amino acid as a boron delivery agent for neutron capture therapy of the F98 rat glioma.

    PubMed

    Futamura, Gen; Kawabata, Shinji; Nonoguchi, Naosuke; Hiramatsu, Ryo; Toho, Taichiro; Tanaka, Hiroki; Masunaga, Shin-Ichiro; Hattori, Yoshihide; Kirihata, Mitsunori; Ono, Koji; Kuroiwa, Toshihiko; Miyatake, Shin-Ichi

    2017-01-23

    Boron neutron capture therapy (BNCT) is a unique particle radiation therapy based on the nuclear capture reactions in boron-10. We developed a novel boron-10 containing sodium borocaptate (BSH) derivative, 1-amino-3-fluorocyclobutane-1-carboxylic acid (ACBC)-BSH. ACBC is a tumor selective synthetic amino acid. The purpose of this study was to assess the biodistribution of ACBC-BSH and its therapeutic efficacy following Boron Neutron Capture Therapy (BNCT) of the F98 rat glioma. We evaluated the biodistribution of three boron-10 compounds, ACBC-BSH, BSH and boronophenylalanine (BPA), in vitro and in vivo, following intravenous (i.v.) administration and intratumoral (i.t.) convection-enhanced delivery (CED) in F98 rat glioma bearing rats. For BNCT studies, rats were stratified into five groups: untreated controls, neutron-irradiation controls, BNCT with BPA/i.v., BNCT with ACBC-BSH/CED, and BNCT concomitantly using BPA/i.v. and ACBC-BSH/CED. In vitro, ACBC-BSH attained higher cellular uptake F98 rat glioma cells compared with BSH. In vivo biodistribution studies following i.v. administration and i.t. CED of ACBC-BSH attained significantly higher boron concentrations than that of BSH, but much lower than that of BPA. However, following convection enhanced delivery (CED), ACBC-BSH attained significantly higher tumor concentrations than BPA. The i.t. boron-10 concentrations were almost equal between the ACBC-BSH/CED group and BPA/i.v. group of rats. The tumor/brain boron-10 concentration ratio was higher with ACBC-BSH/CED than that of BPA/i.v. group. Based on these data, BNCT studies were carried out in F98 glioma bearing rats using BPA/i.v. and ACBC-BSH/CED as the delivery agents. The corresponding mean survival times were 37.4 ± 2.6d and 44.3 ± 8.0d, respectively, and although modest, these differences were statistically significant. Our findings suggest that further studies are warranted to evaluate ACBC-BSH/CED as a boron delivery agent.

  17. Improved Vote Aggregation Techniques for the Geo-Wiki Cropland Capture Crowdsourcing Game

    NASA Astrophysics Data System (ADS)

    Baklanov, Artem; Fritz, Steffen; Khachay, Michael; Nurmukhametov, Oleg; Salk, Carl; See, Linda; Shchepashchenko, Dmitry

    2016-04-01

    Crowdsourcing is a new approach for solving data processing problems for which conventional methods appear to be inaccurate, expensive, or time-consuming. Nowadays, the development of new crowdsourcing techniques is mostly motivated by so called Big Data problems, including problems of assessment and clustering for large datasets obtained in aerospace imaging, remote sensing, and even in social network analysis. By involving volunteers from all over the world, the Geo-Wiki project tackles problems of environmental monitoring with applications to flood resilience, biomass data analysis and classification of land cover. For example, the Cropland Capture Game, which is a gamified version of Geo-Wiki, was developed to aid in the mapping of cultivated land, and was used to gather 4.5 million image classifications from the Earth's surface. More recently, the Picture Pile game, which is a more generalized version of Cropland Capture, aims to identify tree loss over time from pairs of very high resolution satellite images. Despite recent progress in image analysis, the solution to these problems is hard to automate since human experts still outperform the majority of machine learning algorithms and artificial systems in this field on certain image recognition tasks. The replacement of rare and expensive experts by a team of distributed volunteers seems to be promising, but this approach leads to challenging questions such as: how can individual opinions be aggregated optimally, how can confidence bounds be obtained, and how can the unreliability of volunteers be dealt with? In this paper, on the basis of several known machine learning techniques, we propose a technical approach to improve the overall performance of the majority voting decision rule used in the Cropland Capture Game. The proposed approach increases the estimated consistency with expert opinion from 77% to 86%.

  18. [Attempt at scientific theoretical classification of behavior therapy].

    PubMed

    Reinecker, H

    1976-01-01

    Following the discussion about the position of behavior therapy there are mentioned some problems of behaviorism, the connection between behavior therapy and learning theory and problems of etiology and treatment. The usefulness of known criteria (formal as well as non-formal) should be demonstrated. There are discussed three different positions of behavior therapy within the scientific disciplines.

  19. Capturing Problem-Solving Processes Using Critical Rationalism

    ERIC Educational Resources Information Center

    Chitpin, Stephanie; Simon, Marielle

    2012-01-01

    The examination of problem-solving processes continues to be a current research topic in education. Knowing how to solve problems is not only a key aspect of learning mathematics but is also at the heart of cognitive theories, linguistics, artificial intelligence, and computers sciences. Problem solving is a multistep, higher-order cognitive task…

  20. Effective motion planning strategy for space robot capturing targets under consideration of the berth position

    NASA Astrophysics Data System (ADS)

    Zhang, Xin; Liu, Jinguo

    2018-07-01

    Although many motion planning strategies for missions involving space robots capturing floating targets can be found in the literature, relatively little has discussed how to select the berth position where the spacecraft base hovers. In fact, the berth position is a flexible and controllable factor, and selecting a suitable berth position has a great impact on improving the efficiency of motion planning in the capture mission. Therefore, to make full use of the manoeuvrability of the space robot, this paper proposes a new viewpoint that utilizes the base berth position as an optimizable parameter to formulate a more comprehensive and effective motion planning strategy. Considering the dynamic coupling, the dynamic singularities, and the physical limitations of space robots, a unified motion planning framework based on the forward kinematics and parameter optimization technique is developed to convert the planning problem into the parameter optimization problem. For getting rid of the strict grasping position constraints in the capture mission, a new conception of grasping area is proposed to greatly simplify the difficulty of the motion planning. Furthermore, by utilizing the penalty function method, a new concise objective function is constructed. Here, the intelligent algorithm, Particle Swarm Optimization (PSO), is worked as solver to determine the free parameters. Two capturing cases, i.e., capturing a two-dimensional (2D) planar target and capturing a three-dimensional (3D) spatial target, are studied under this framework. The corresponding simulation results demonstrate that the proposed method is more efficient and effective for planning the capture missions.

  1. Family therapy in treatment of the deaf: a case report.

    PubMed

    Shapiro, R J; Harris, R I

    1976-03-01

    Deaf patients with psychological problems have developmental handicaps and clinical characteristics that reduce the effectiveness of traditional modes of psychotherapy. Attempts have been made to utilize individual and group therapy, but family therapy has been largely overlooked as a method of alleviating problems of the deaf. Clinical and research writings provide us with rich insights into the family dynamics of the deaf. These data suggest to the authors that the problems of deaf individuals are largely related to family problems, and therefore merit a family orientation as the focus for treatment. This paper describes an attempt to apply family therapy with a range of deaf patients over a period of two years. From a review of their work, the authors conclude that family therapy can be effective, particularly in the treatment of deaf adolescents and children.

  2. Why Is the Overheating Problem Difficult: the Role of Entropy

    NASA Technical Reports Server (NTRS)

    Liou, Meng-Sing

    2013-01-01

    The development of computational fluid dynamics over the last few decades has yielded enormous successes and capabilities being routinely employed today; however there remain some open problems to be properly resolved-some are fundamental in nature and some resolvable by operational changes. These two categories are distinguished and broadly explored previously. One, that belongs to the former, is the so-called overheating problem, especially in rarefying flow. This problem up to date still dogs every method known to the author; a solution to it remains elusive. The study in this paper concludes that: (1) the entropy increase is quantitatively linked to the increase in the temperature increase, (2) it is argued that the overheating is inevitable in the current shock capturing or traditional finite difference framework, and (3) a simple hybrid method is proposed that removes the overheating problem in the rarefying problems, but also retains the property of accurate shock capturing. This remedy (enhancement of current numerical methods) can be included easily in the present Eulerian codes.

  3. An Ontology of Therapies

    NASA Astrophysics Data System (ADS)

    Eccher, Claudio; Ferro, Antonella; Pisanelli, Domenico M.

    Ontologies are the essential glue to build interoperable systems and the talk of the day in the medical community. In this paper we present the ontology of medical therapies developed in the course of the Oncocure project, aimed at building a guideline based decision support integrated with a legacy Electronic Patient Record (EPR). The therapy ontology is based upon the DOLCE top level ontology. It is our opinion that our ontology, besides constituting a model capturing the precise meaning of therapy-related concepts, can serve for several practical purposes: interfacing automatic support systems with a legacy EPR, allowing the automatic data analysis, and controlling possible medical errors made during EPR data input.

  4. Estimating breeding proportions and testing hypotheses about costs of reproduction with capture-recapture data

    USGS Publications Warehouse

    Nichols, James D.; Hines, James E.; Pollock, Kenneth H.; Hinz, Robert L.; Link, William A.

    1994-01-01

    The proportion of animals in a population that breeds is an important determinant of population growth rate. Usual estimates of this quantity from field sampling data assume that the probability of appearing in the capture or count statistic is the same for animals that do and do not breed. A similar assumption is required by most existing methods used to test ecologically interesting hypotheses about reproductive costs using field sampling data. However, in many field sampling situations breeding and nonbreeding animals are likely to exhibit different probabilities of being seen or caught. In this paper, we propose the use of multistate capture-recapture models for these estimation and testing problems. This methodology permits a formal test of the hypothesis of equal capture/sighting probabilities for breeding and nonbreeding individuals. Two estimators of breeding proportion (and associated standard errors) are presented, one for the case of equal capture probabilities and one for the case of unequal capture probabilities. The multistate modeling framework also yields formal tests of hypotheses about reproductive costs to future reproduction or survival or both fitness components. The general methodology is illustrated using capture-recapture data on female meadow voles, Microtus pennsylvanicus. Resulting estimates of the proportion of reproductively active females showed strong seasonal variation, as expected, with low breeding proportions in midwinter. We found no evidence of reproductive costs extracted in subsequent survival or reproduction. We believe that this methodological framework has wide application to problems in animal ecology concerning breeding proportions and phenotypic reproductive costs.

  5. Calibration of the borated ion chamber at NIST reactor thermal column.

    PubMed

    Wang, Z; Hertel, N E; Lennox, A

    2007-01-01

    In boron neutron capture therapy and boron neutron capture enhanced fast neutron therapy, the absorbed dose of tissue due to the boron neutron capture reaction is difficult to measure directly. This dose can be computed from the measured thermal neutron fluence rate and the (10)B concentration at the site of interest. A borated tissue-equivalent (TE) ion chamber can be used to directly measure the boron dose in a phantom under irradiation by a neutron beam. Fermilab has two Exradin 0.5 cm(3) Spokas thimble TE ion chambers, one loaded with boron, available for such measurements. At the Fermilab Neutron Therapy Facility, these ion chambers are generally used with air as the filling gas. Since alpha particles and lithium ions from the (10)B(n,alpha)(7)Li reactions have very short ranges in air, the Bragg-Gray principle may not be satisfied for the borated TE ion chamber. A calibration method is described in this paper for the determination of boron capture dose using paired ion chambers. The two TE ion chambers were calibrated in the thermal column of the National Institute of Standards and Technology (NIST) research reactor. The borated TE ion chamber is loaded with 1,000 ppm of natural boron (184 ppm of (10)B). The NIST thermal column has a cadmium ratio of greater than 400 as determined by gold activation. The thermal neutron fluence rate during the calibration was determined using a NIST fission chamber to an accuracy of 5.1%. The chambers were calibrated at two different thermal neutron fluence rates: 5.11 x 10(6) and 4.46 x 10(7)n cm(-2) s(-1). The non-borated ion chamber reading was used to subtract collected charge not due to boron neutron capture reactions. An optically thick lithium slab was used to attenuate the thermal neutrons from the neutron beam port so the responses of the chambers could be corrected for fast neutrons and gamma rays in the beam. The calibration factor of the borated ion chamber was determined to be 1.83 x 10(9) +/- 5.5% (+/- 1sigma) n cm(-2) per nC at standard temperature and pressure condition.

  6. MCNP simulation of the dose distribution in liver cancer treatment for BNC therapy

    NASA Astrophysics Data System (ADS)

    Krstic, Dragana; Jovanovic, Zoran; Markovic, Vladimir; Nikezic, Dragoslav; Urosevic, Vlade

    2014-10-01

    The Boron Neutron Capture Therapy ( BNCT) is based on selective uptake of boron in tumour tissue compared to the surrounding normal tissue. Infusion of compounds with boron is followed by irradiation with neutrons. Neutron capture on 10B, which gives rise to an alpha particle and recoiled 7Li ion, enables the therapeutic dose to be delivered to tumour tissue while healthy tissue can be spared. Here, therapeutic abilities of BNCT were studied for possible treatment of liver cancer using thermal and epithermal neutron beam. For neutron transport MCNP software was used and doses in organs of interest in ORNL phantom were evaluated. Phantom organs were filled with voxels in order to obtain depth-dose distributions in them. The result suggests that BNCT using an epithermal neutron beam could be applied for liver cancer treatment.

  7. Human radiation studies: Remembering the early years: Oral history of physician James S. Robertson, M.D., Ph.D., conducted January 20, 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-09-01

    This report is a transcript of in interview of Dr. James S. Robertson by representatives of the DOE Office of Human Radiation Experiments. Dr. Robertson was chosen for this interview because of his research at Brookhaven National Laboratory, especially on Boron Neutron Capture Therapy (BNCT); his work at the United States Naval Defense Laboratory; and his work at the Atomic Energy Commission. After a brief biographical sketch Dr. Robertson discusses research on human subjects at Berkeley, his contributions to the beginnings of Neutron Capture Therapy at Brookhaven, his participation with the Brookhaven Human Use Committee, his involvement in the studymore » of the effects of Castle Bravo event on the Marshallese, and his work with the Naval Radiological Defense Laboratory.« less

  8. Analysis on the emission and potential application of Cherenkov radiation in boron neutron capture therapy: A Monte Carlo simulation study.

    PubMed

    Shu, Di-Yun; Geng, Chang-Ran; Tang, Xiao-Bin; Gong, Chun-Hui; Shao, Wen-Cheng; Ai, Yao

    2018-07-01

    This paper was aimed to explore the physics of Cherenkov radiation and its potential application in boron neutron capture therapy (BNCT). The Monte Carlo toolkit Geant4 was used to simulate the interaction between the epithermal neutron beam and the phantom containing boron-10. Results showed that Cherenkov photons can only be generated from secondary charged particles of gamma rays in BNCT, in which the 2.223 MeV prompt gamma rays are the main contributor. The number of Cherenkov photons per unit mass generated in the measurement region decreases linearly with the increase of boron concentration in both water and tissue phantom. The work presented the fundamental basis for applications of Cherenkov radiation in BNCT. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Boron analysis for neutron capture therapy using particle-induced gamma-ray emission.

    PubMed

    Nakai, Kei; Yamamoto, Yohei; Okamoto, Emiko; Yamamoto, Tetsuya; Yoshida, Fumiyo; Matsumura, Akira; Yamada, Naoto; Kitamura, Akane; Koka, Masashi; Satoh, Takahiro

    2015-12-01

    The neutron source of BNCT is currently changing from reactor to accelerator, but peripheral facilities such as a dose-planning system and blood boron analysis have still not been established. To evaluate the potential application of particle-induced gamma-ray emission (PIGE) for boron measurement in clinical boron neutron capture therapy, boronophenylalanine dissolved within a cell culture medium was measured using PIGE. PIGE detected 18 μgB/mL f-BPA in the culture medium, and all measurements of any given sample were taken within 20 min. Two hours of f-BPA exposure was required to create a boron distribution image. However, even though boron remained in the cells, the boron on the cell membrane could not be distinguished from the boron in the cytoplasm. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. E-therapy for mental health problems: a systematic review.

    PubMed

    Postel, Marloes G; de Haan, Hein A; De Jong, Cor A J

    2008-09-01

    The widespread availability of the Internet offers opportunities for improving access to therapy for people with mental health problems. There is a seemingly infinite supply of Internet-based interventions available on the World Wide Web. The aim of the present study is to systematically assess the methodological quality of randomized controlled trials (RCTs) concerning e-therapy for mental health problems. Two reviewers independently assessed the methodological quality of the RCTs, based on a list of criteria for the methodological quality assessment as recommended by the Cochrane Back Review Group. The search yielded 14 papers that reported RCTs concerning e-therapy for mental-health problems. The methodological quality of studies included in this review was generally low. It is concluded that e-therapy may turn out to be an appropriate therapeutic entity, but the evidence needs to be more convincing. Recommendations are made concerning the method of reporting RCTs and the need to add some content items to an e-therapy study.

  11. Biocompatibility of functionalized boron phosphate (BPO4) nanoparticles for boron neutron capture therapy (BNCT) application.

    PubMed

    Achilli, Cesare; Grandi, Stefania; Ciana, Annarita; Guidetti, Gianni F; Malara, Alessandro; Abbonante, Vittorio; Cansolino, Laura; Tomasi, Corrado; Balduini, Alessandra; Fagnoni, Maurizio; Merli, Daniele; Mustarelli, Piercarlo; Canobbio, Ilaria; Balduini, Cesare; Minetti, Giampaolo

    2014-04-01

    Boron neutron capture therapy (BNCT) is a radiotherapy treatment based on the accumulation in the tumor of a (10)B-containing drug and subsequent irradiation with low energy neutrons, which bring about the decay of (10)B to (7)Li and an α particle, causing the death of the neoplastic cell. The effectiveness of BNCT is limited by the low delivery and accumulation of the used boron-containing compounds. Here we report the development and the characterization of BPO4 nanoparticles (NPs) as a novel possible alternative drug for BNCT. An extensive analysis of BPO4 NP biocompatibility was performed using both mature blood cells (erythrocytes, neutrophils and platelets) and a model of hematopoietic progenitor cells. A time- and concentration-dependent cytotoxicity study was performed on neoplastic coloncarcinoma and osteosarcoma cell lines. BPO4 functionalization with folic acid, introduced to improve the uptake by tumor cells, appeared to effectively limit the unwanted effects of NPs on the analyzed blood components. Boron neutron capture therapy (BNCT) is a radiotherapy treatment modality based on the accumulation of a (10)B-containing drug and subsequent irradiation with low energy neutrons, inducing the decay of (10)B to (7)Li and an α particle, causing neoplastic cell death. This team of authors reports on a folic acid functionalized BPO4 nanoparticle with improved characteristics compared with conventional BNCT approaches, as demonstrated in tumor cell lines, and hopefully to be followed by translational human studies. © 2014.

  12. Intrathecal baclofen therapy in paediatrics: a study protocol for an Australian multicentre, 10-year prospective audit

    PubMed Central

    Stewart, Kirsty; Hutana, Gavin; Kentish, Megan

    2017-01-01

    Introduction Increasing clinical use of Intrathecal baclofen (ITB) in Australian tertiary paediatric hospitals, along with the need for standardised assessment and reporting of adverse events, saw the formation of the Australian Paediatric ITB Research Group (APIRG). APIRG developed a National ITB Audit tool designed to capture clinical outcomes and adverse events data for all Australian children and adolescents receiving ITB therapy. Methods and analysis The Australian ITB Audit is a 10 year, longitudinal, prospective, clinical audit collecting all adverse events and assessment data across body functions and structure, participation and activity level domains of the ICF. Data will be collected at baseline, 6 and 12 months with ongoing capture of all adverse event data. This is the first Australian study that aims to capture clinical and adverse event data from a complete population of children with neurological impairment receiving a specific intervention between 2011 and 2021. This multi-centre study will inform ITB clinical practice in children and adolescents, direct patient selection, record and aid decision making regarding adverse events and investigate the impact of ITB therapy on family and patient quality of life. Ethics and dissemination This project was approved by the individual Human Research Ethics committees at the six Australian tertiary hospitals involved in the study. Results will be published in various peer reviewed journals and presented at national and international conferences. Trial registration number ACTRN 12610000323022; Pre-results. PMID:28637739

  13. A theranostic approach based on the use of a dual boron/Gd agent to improve the efficacy of Boron Neutron Capture Therapy in the lung cancer treatment.

    PubMed

    Alberti, Diego; Protti, Nicoletta; Toppino, Antonio; Deagostino, Annamaria; Lanzardo, Stefania; Bortolussi, Silva; Altieri, Saverio; Voena, Claudia; Chiarle, Roberto; Geninatti Crich, Simonetta; Aime, Silvio

    2015-04-01

    This study aims at developing an innovative theranostic approach for lung tumor and metastases treatment, based on Boron Neutron Capture Therapy (BNCT). It relies on to the use of low density lipoproteins (LDL) as carriers able to maximize the selective uptake of boron atoms in tumor cells and, at the same time, to quantify the in vivo boron distribution by magnetic resonance imaging (MRI). Tumor cells uptake was initially assessed by ICP-MS and MRI on four types of tumor (TUBO, B16-F10, MCF-7, A549) and one healthy (N-MUG) cell lines. Lung metastases were generated by intravenous injection of a Her2+ breast cancer cell line (i.e. TUBO) in BALB/c mice and transgenic EML4-ALK mice were used as primary tumor model. After neutron irradiation, tumor growth was followed for 30-40 days by MRI. Tumor masses of boron treated mice increased markedly slowly than the control group. From the clinical editor: In this article, the authors described an improvement to existing boron neutron capture therapy. The dual MRI/BNCT agent, carried by LDLs, was able to maximize the selective uptake of boron in tumor cells, and, at the same time, quantify boron distribution in tumor and in other tissues using MRI. Subsequent in vitro and in vivo experiments showed tumor cell killing after neutron irradiation. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Novel Hyaluronan Formulation Enhances the Efficacy of Boron Neutron Capture Therapy for Murine Mesothelioma.

    PubMed

    Sasai, Masao; Nakamura, Hiroyuki; Sougawa, Nagako; Sakurai, Yoshinori; Suzuki, Minoru; Lee, Chun Man

    2016-03-01

    Malignant pleural mesothelioma (MPM) is a refractory cancer of the pleura caused by asbestos exposure. MPM is difficult to treat because it easily disseminates. Boron neutron capture therapy (BNCT) is a radiotherapy in which cancer cells that selectively take up (10)Boron-containing compounds are destroyed, and normal cells are uninjured. Hyaluronan (HA) is a ligand of cluster of differentiation 44 (CD44), that is expressed on MPM cells. In order to enhance BNCT for MPM tumors, we developed a novel HA-containing (10)B (sodium borocaptate: BSH) formulation (HA-BND-S). We examined the efficacy of HA-BND-S using MPM cells and a mouse MPM model. HA-BND-S preferentially bound MPM cells dose-dependently, and increased the cytotoxicity of BNCT compared to BSH in vitro. HA-BND-S administration significantly increased the survival of MPM tumor-bearing mice compared to BSH at the same (10)B dosage in BNCT. Modifying BSH with HA is a promising strategy for enhancing the efficacy of BNCT for therapy of MPM. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  15. A Look to Future Directions in Gene Therapy Research for Monogenic Diseases

    PubMed Central

    Porteus, Matthew H; Connelly, Jon P; Pruett, Shondra M

    2006-01-01

    The concept of gene therapy has long appealed to biomedical researchers and clinicians because it promised to treat certain diseases at their origins. In the last several years, there have been several trials in which patients have benefited from gene therapy protocols. This progress, however, has revealed important problems, including the problem of insertional oncogenesis. In this review, which focuses on monogenic diseases, we discuss the problem of insertional oncogenesis and identify areas for future research, such as developing more quantitative assays for risk and efficacy, and ways of minimizing the genotoxic effects of gene therapy protocols, which will be important if gene therapy is to fulfill its conceptual promise. PMID:17009872

  16. Couple therapy for depression.

    PubMed

    Whisman, Mark A; Beach, Steven R H

    2012-05-01

    Relationship problems and depression often influence one another in a bidirectional, recursive fashion. Results from several clinical trials have demonstrated that couple therapy is effective in improving depression and reducing relationship problems. In this article, we describe an approach to working with depression in partnered individuals who are also unhappy in their relationship. This cognitive-behavior approach strives to (a) eliminate major stressors and reestablish positive activities in the relationship, (b) improve communication and problem solving in the relationship, and (c) solidify gains made in therapy and prevent relapse. The typical course of therapy is described and demonstrated in a case illustration. Couple therapy is a promising treatment for depressed individuals in distressed relationships. © 2012 Wiley Periodicals, Inc.

  17. Benchmark Problems for Spacecraft Formation Flying Missions

    NASA Technical Reports Server (NTRS)

    Carpenter, J. Russell; Leitner, Jesse A.; Burns, Richard D.; Folta, David C.

    2003-01-01

    To provide high-level focus to distributed space system flight dynamics and control research, several benchmark problems are suggested. These problems are not specific to any current or proposed mission, but instead are intended to capture high-level features that would be generic to many similar missions.

  18. Quantitative analysis of arm movement smoothness

    NASA Astrophysics Data System (ADS)

    Szczesna, Agnieszka; Błaszczyszyn, Monika

    2017-07-01

    The paper deals with the problem of motion data quantitative smoothness analysis. We investigated values of movement unit, fluidity and jerk for healthy and paralyzed arm of patients with hemiparesis after stroke. Patients were performing drinking task. To validate the approach, movement of 24 patients were captured using optical motion capture system.

  19. Application of an octa-anionic 5,10,15,20-tetra[3,5-(nido-carboranylmethyl)phenyl]porphyrin (H2OCP) as dual sensitizer for BNCT and PDT

    USDA-ARS?s Scientific Manuscript database

    The applications of the octa-anionic 5,10,15,20-tetra[3,5-(nidocarboranylmethyl) phenyl]porphyrin (H2OCP) as a boron delivery agent in boron neutron capture therapy (BNCT) and a photosensitizer in photodynamic therapy (PDT) have been investigated. Using F98 Rat glioma cells, we evaluated the cytotox...

  20. L-Phenylalanine preloading reduces the (10)B(n, α)(7)Li dose to the normal brain by inhibiting the uptake of boronophenylalanine in boron neutron capture therapy for brain tumours.

    PubMed

    Watanabe, Tsubasa; Tanaka, Hiroki; Fukutani, Satoshi; Suzuki, Minoru; Hiraoka, Masahiro; Ono, Koji

    2016-01-01

    Boron neutron capture therapy (BNCT) is a cellular-level particle radiation therapy that combines the selective delivery of boron compounds to tumour tissue with neutron irradiation. Previously, high doses of one of the boron compounds used for BNCT, L-BPA, were found to reduce the boron-derived irradiation dose to the central nervous system. However, injection with a high dose of L-BPA is not feasible in clinical settings. We aimed to find an alternative method to improve the therapeutic efficacy of this therapy. We examined the effects of oral preloading with various analogues of L-BPA in a xenograft tumour model and found that high-dose L-phenylalanine reduced the accumulation of L-BPA in the normal brain relative to tumour tissue. As a result, the maximum irradiation dose in the normal brain was 19.2% lower in the L-phenylalanine group relative to the control group. This study provides a simple strategy to improve the therapeutic efficacy of conventional boron compounds for BNCT for brain tumours and the possibility to widen the indication of BNCT to various kinds of other tumours. Copyright © 2015. Published by Elsevier Ireland Ltd.

  1. Effective capture and release of circulating tumor cells using core-shell Fe3O4@MnO2 nanoparticles

    NASA Astrophysics Data System (ADS)

    Xiao, Liang; He, Zhao-Bo; Cai, Bo; Rao, Lang; Cheng, Long; Liu, Wei; Guo, Shi-Shang; Zhao, Xing-Zhong

    2017-01-01

    Circulating tumor cells (CTCs) have been believed to hold significant insights for cancer diagnosis and therapy. Here, we developed a simple and effective method to capture and release viable CTCs using core-shell Fe3O4@MnO2 nanoparticles. Fe3O4@MnO2 nanoparticles bioconjugated with anti-EpCAM antibody have characteristics of specific recognition, magnetic-driven cell isolation and oxalic acid-assisted cell release. The capture and release efficiency of target cancer cells were ∼83% and ∼55%, respectively. And ∼70% of released cells kept good viability, which could facilitate the subsequent cellular analysis.

  2. Psychosocial distress of part-time occlusion in children with intermittent exotropia.

    PubMed

    Kim, Ungsoo Samuel; Park, Subin; Yoo, Hee Jeong; Hwang, Jeong-Min

    2013-01-01

    To evaluate the psychosocial distress of part-time occlusion therapy in intermittent exotropia. A total of 25 children (15 males and 10 females, aged 3 to 7 years, mean age 4.7 years) with intermittent exotropia were enrolled. Behavioral and psychosocial problems were assessed by the Korean Child Behavior Checklist (K-CBCL), which consists of eight categories of withdrawal, somatic problems, depression/anxiety, social problems, thought problems, attention problems, delinquent behavior, and aggressive behavior, and the Amblyopia Treatment Index (ATI). The ATI was designed to evaluate the three factors of compliance, adverse effect, and social stigma. The Parenting Stress Index (PSI) is a parent self-report designed to identify potentially dysfunctional parent-child systems. The K-CBCL was obtained before and after occlusion therapy, and the ATI and PSI were taken from parents only after occlusion therapy. We evaluated the change on the K-CBCL and the correlation between the K-CBCL and ATI. The attention problem assessed by the K-CBCL significantly decreased after occlusion therapy. On the ATI, the social stigma was relatively lower than compliance and adverse effect factors (Likert scale 2.64, 3.11, and 3.11, respectively). The somatic problem assessed by the K-CBCL and compliance on the ATI were significantly correlated (p = 0.014). There was no significant change in percentile scores of each subscale (parental dominant scale and child dominant scale) of the PSI. Total stress index before and after occlusion therapy was 97.16 ± 8.38 and 97.00 ± 8.16 respectively (p = 0.382). Occlusion therapy may influence the psychosocial impact on intermittent exotropia patients. Part-time occlusion significantly decreased the attention problem in children with intermittent strabismus. Children with a high somatic problem score on the KCBCL showed poor compliance to the part-time occlusion.

  3. Summary of the Tandem Cylinder Solutions from the Benchmark Problems for Airframe Noise Computations-I Workshop

    NASA Technical Reports Server (NTRS)

    Lockard, David P.

    2011-01-01

    Fifteen submissions in the tandem cylinders category of the First Workshop on Benchmark problems for Airframe Noise Computations are summarized. Although the geometry is relatively simple, the problem involves complex physics. Researchers employed various block-structured, overset, unstructured and embedded Cartesian grid techniques and considerable computational resources to simulate the flow. The solutions are compared against each other and experimental data from 2 facilities. Overall, the simulations captured the gross features of the flow, but resolving all the details which would be necessary to compute the noise remains challenging. In particular, how to best simulate the effects of the experimental transition strip, and the associated high Reynolds number effects, was unclear. Furthermore, capturing the spanwise variation proved difficult.

  4. Monitoring Affect States during Effortful Problem Solving Activities

    ERIC Educational Resources Information Center

    D'Mello, Sidney K.; Lehman, Blair; Person, Natalie

    2010-01-01

    We explored the affective states that students experienced during effortful problem solving activities. We conducted a study where 41 students solved difficult analytical reasoning problems from the Law School Admission Test. Students viewed videos of their faces and screen captures and judged their emotions from a set of 14 states (basic…

  5. Student Errors in Dynamic Mathematical Environments

    ERIC Educational Resources Information Center

    Brown, Molly; Bossé, Michael J.; Chandler, Kayla

    2016-01-01

    This study investigates the nature of student errors in the context of problem solving and Dynamic Math Environments. This led to the development of the Problem Solving Action Identification Framework; this framework captures and defines all activities and errors associated with problem solving in a dynamic math environment. Found are three…

  6. Path Planning Algorithms for Autonomous Border Patrol Vehicles

    NASA Astrophysics Data System (ADS)

    Lau, George Tin Lam

    This thesis presents an online path planning algorithm developed for unmanned vehicles in charge of autonomous border patrol. In this Pursuit-Evasion game, the unmanned vehicle is required to capture multiple trespassers on its own before any of them reach a target safe house where they are safe from capture. The problem formulation is based on Isaacs' Target Guarding problem, but extended to the case of multiple evaders. The proposed path planning method is based on Rapidly-exploring random trees (RRT) and is capable of producing trajectories within several seconds to capture 2 or 3 evaders. Simulations are carried out to demonstrate that the resulting trajectories approach the optimal solution produced by a nonlinear programming-based numerical optimal control solver. Experiments are also conducted on unmanned ground vehicles to show the feasibility of implementing the proposed online path planning algorithm on physical applications.

  7. The Assessment of Change in Training and Therapy.

    ERIC Educational Resources Information Center

    Belasco, James A.; Trice, Harrison M.

    Designed to serve training oriented professionals, therapy oriented practitioners, and practicing managers, this book presents insights into the change process, along with problems contained in efforts to evaluate this process in management training and in therapy. First, the four essential strategic problems of evaluation are set forth: setting…

  8. Using Rational-Emotive Therapy to Prevent Classroom Problems.

    ERIC Educational Resources Information Center

    Webber, Jo; Coleman, Maggie

    1988-01-01

    Teachers are encouraged to utilize rational-emotive therapy to prevent and deal with classroom behavior problems. Rational-emotive therapy is defined, the ABC model of rational thinking briefly explained, types of irrational thinking identified, and suggestions for becoming a rational thinker are offered. Classroom examples are given. (DB)

  9. Basic Research Needs for Carbon Capture: Beyond 2020

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alivisatos, Paul; Buchanan, Michelle

    2010-03-04

    This report is based on a SC/FE workshop on Carbon Capture: Beyond 2020, held March 4–5, 2010, to assess the basic research needed to address the current technical bottlenecks in carbon capture processes and to identify key research priority directions that will provide the foundations for future carbon capture technologies. The problem of thermodynamically efficient and scalable carbon capture stands as one of the greatest challenges for modern energy researchers. The vast majority of US and global energy use derives from fossil fuels, the combustion of which results in the emission of carbon dioxide into the atmosphere. These anthropogenic emissionsmore » are now altering the climate. Although many alternatives to combustion are being considered, the fact is that combustion will remain a principal component of the global energy system for decades to come. Today’s carbon capture technologies are expensive and cumbersome and energy intensive. If scientists could develop practical and cost-effective methods to capture carbon, those methods would at once alter the future of the largest industry in the world and provide a technical solution to one of the most vexing problems facing humanity. The carbon capture problem is a true grand challenge for today’s scientists. Postcombustion CO2 capture requires major new developments in disciplines spanning fundamental theoretical and experimental physical chemistry, materials design and synthesis, and chemical engineering. To start with, the CO2 molecule itself is thermodynamically stable and binding to it requires a distortion of the molecule away from its linear and symmetric arrangement. This binding of the gas molecule cannot be too strong, however; the sheer quantity of CO2 that must be captured ultimately dictates that the capture medium must be recycled over and over. Hence the CO2 once bound, must be released with relatively little energy input. Further, the CO2 must be rapidly and selectively pulled out of a mixture that contains many other gaseous components. The related processes of precombustion capture and oxycombustion pose similar challenges. It is this nexus of high-speed capture with high selectivity and minimal energy loss that makes this a true grand challenge problem, far beyond any of today’s artificial molecular manipulation technologies, and one whose solution will drive the advancement of molecular science to a new level of sophistication. We have only to look to nature, where such chemical separations are performed routinely, to imagine what may be achieved. The hemoglobin molecule transports oxygen in the blood rapidly and selectively and releases it with minimal energy penalty. Despite our improved understanding of how this biological system works, we have yet to engineer a molecular capture system that uses the fundamental cooperativity process that lies at the heart of the functionality of hemoglobin. While such biological examples provide inspiration, we also note that newly developed theoretical and computational capabilities; the synthesis of new molecules, materials, and membranes; and the remarkable advances in characterization techniques enabled by the Department of Energy’s measurement facilities all create a favorable environment for a major new basic research push to solve the carbon capture problem within the next decade. The Department of Energy has established a comprehensive strategy to meet the nation’s needs in the carbon capture arena. This framework has been developed following a series of workshops that have engaged all the critical stakeholder communities. The strategy that has emerged is based upon a tiered approach, with Fossil Energy taking the lead in a series of applied research programs that will test and extend our current systems. ARPA-E (Advanced Research Projects Agency–Energy) is supporting potential breakthroughs based upon innovative proposals to rapidly harness today’s technical capabilities in ways not previously considered. These needs and plans have been well summarized in the report from a recent workshop—Carbon Capture 2020, held in October 5 and 6, 2009—focused on near-term strategies for carbon capture improvements (http://www.netl.doe.gov/publications/ proceedings/09/CC2020/pdfs/Richards_Summary.pdf ). Yet the fact remains that when the carbon capture problem is looked at closely, we see today’s technologies fall far short of making carbon capture an economically viable process. This situation reinforces the need for a parallel, intensive use-inspired basic research effort to address the problem. This was the overwhelming conclusion of a recent workshop—Carbon Capture: Beyond 2020, held March 4 and 5, 2010—and is the subject of the present report. To prepare for the second workshop, an in-depth assessment of current technologies for carbon capture was conducted; the result of this study was a factual document, Technology and Applied R&D Needs for Carbon Capture: Beyond 2020. This document, which was prepared by experts in current carbon capture processes, also summarized the technological gaps or bottlenecks that limit currently available carbon capture technologies. The report considered the separation processes needed for all three CO2 emission reduction strategies—postcombustion, precombustion, and oxycombustion—and assessed three primary separation technologies based on liquid absorption, membranes, and solid adsorption. The workshop “Carbon Capture: Beyond 2020” convened approximately 80 attendees from universities, national laboratories, and industry to assess the basic research needed to address the current technical bottlenecks in carbon capture processes and to identify key research priority directions that will provide the foundations for future carbon capture technologies. The workshop began with a plenary session including speakers who summarized the extent of the carbon capture challenge, the various current approaches, and the limitations of these technologies. Workshop attendees were then given the charge to identify high-priority basic research directions that could provide revolutionary new concepts to form the basis for separation technologies in 2020 and beyond. The participants were divided into three major panels corresponding to different approaches for separating gases to reduce carbon emissions—liquid absorption, solid adsorption, and membrane separations. Two other panels were instructed to attend each of these three technology panels to assess crosscutting issues relevant to characterization and computation. At the end of the workshop, a final plenary session was convened to summarize the most critical research needs identified by the workshop attendees in each of the three major technical panels and from the two cross-cutting panels. The reports of the three technical panels included a set of high level Priority Research Directions meant to serve as inspiration to researchers in multiple disciplines—materials science, chemistry, biology, computational science, engineering, and others—to address the huge scientific challenges facing this nation and the world as we seek technologies for large-scale carbon capture beyond 2020. These Priority Research Directions were clustered around three main areas, all tightly coupled: Understand and control the dynamic atomic-level and molecular-level interactions of the targeted species with the separation media. Discover and design new materials that incorporate designed structures and functionalities tuned for optimum separation properties. Tailor capture/release processes with alternative driving forces, taking advantage of a new generation of materials. In each of the technical panels, the participants identified two major crosscutting research themes. The first was the development of new analytical tools that can characterize materials structure and molecular processes across broad spatial and temporal scales and under realistic conditions that mimic those encountered in actual separation processes. Such tools are needed to examine interfaces and thin films at the atomic and molecular levels, achieving an atomic/molecular-scale understanding of gas–host structures, kinetics, and dynamics, and understanding and control of nanoscale synthesis in multiple dimensions. A second major crosscutting theme was the development of new computational tools for theory, modeling, and simulation of separation processes. Computational techniques can be used to elucidate mechanisms responsible for observed separations, predict new desired features for advanced separations materials, and guide future experiments, thus complementing synthesis and characterization efforts. These two crosscut areas underscored the fact that the challenge for future carbon capture technologies will be met only with multidisciplinary teams of scientists and engineers. In addition, it was noted that success in this fundamental research area must be closely coupled with successful applied research to ensure the continuing assessment and maturation of new technologies as they undergo scale-up and deployment. Carbon capture is a very rich scientific problem, replete with opportunity for basic researchers to advance the frontiers of science as they engage on one of the most important technical challenges of our times. This workshop report outlines an ambitious agenda for addressing the very difficult problem of carbon capture by creating foundational new basic science. This new science will in turn pave the way for many additional advances across a broad range of scientific disciplines and technology sectors.« less

  10. Apoptosis through Bcl-2/Bax and Cleaved Caspase Up-Regulation in Melanoma Treated by Boron Neutron Capture Therapy

    PubMed Central

    Faião-Flores, Fernanda; Coelho, Paulo Rogério Pinto; Toledo Arruda-Neto, João Dias; Maria-Engler, Silvya Stuchi; Tiago, Manoela; Capelozzi, Vera Luiza; Giorgi, Ricardo Rodrigues; Maria, Durvanei Augusto

    2013-01-01

    Boron neutron capture therapy (BNCT) is a binary treatment involving selective accumulation of boron carriers in a tumor followed by irradiation with a thermal or epithermal neutron beam. The neutron capture reaction with a boron-10 nucleus yields high linear energy transfer (LET) particles, alpha and 7Li, with a range of 5 to 9 µm. These particles can only travel very short distances and release their damaging energy directly into the cells containing the boron compound. We aimed to evaluate proliferation, apoptosis and extracellular matrix (ECM) modifications of B16F10 melanoma and normal human melanocytes after BNCT. The amounts of soluble collagen and Hsp47, indicating collagen synthesis in the ECM, as well as the cellular markers of apoptosis, were investigated. BNCT decreased proliferation, altered the ECM by decreasing collagen synthesis and induced apoptosis by regulating Bcl-2/Bax in melanoma. Additionally, BNCT also increased the levels of TNF receptor and the cleaved caspases 3, 7, 8 and 9 in melanoma. These results suggest that multiple pathways related to cell death and cell cycle arrest are involved in the treatment of melanoma by BNCT. PMID:23527236

  11. Amphiphilic Polycarbonates from Carborane-Installed Cyclic Carbonates as Potential Agents for Boron Neutron Capture Therapy.

    PubMed

    Xiong, Hejian; Wei, Xing; Zhou, Dongfang; Qi, Yanxin; Xie, Zhigang; Chen, Xuesi; Jing, Xiabin; Huang, Yubin

    2016-09-21

    Carboranes with rich boron content have showed significant applications in the field of boron neutron capture therapy. Biodegradable derivatives of carborane-conjugated polymers with well-defined structure and tunable loading of boron atoms are far less explored. Herein, a new family of amphiphilic carborane-conjugated polycarbonates was synthesized by ring-opening polymerization of a carborane-installed cyclic carbonate monomer. Catalyzed by TBD from a poly(ethylene glycol) macroinitiator, the polymerization proceeded to relatively high conversions (>65%), with low polydispersity in a certain range of molecular weight. The boron content was readily tuned by the feed ratio of the monomer and initiator. The resultant amphiphilic polycarbonates self-assembled in water into spherical nanoparticles of different sizes depending on the hydrophilic-to-hydrophobic ratio. It was demonstrated that larger nanoparticles (PN150) were more easily subjected to protein adsorption and captured by the liver, and smaller nanoparticles (PN50) were more likely to enter cancer cells and accumulate at the tumor site. PN50 with thermal neutron irradiation exhibited the highest therapeutic efficacy in vivo. The new synthetic method utilizing amphiphilic biodegradable boron-enriched polymers is useful for developing more-selective and -effective boron delivery systems for BNCT.

  12. Hybrid asymptotic-numerical approach for estimating first-passage-time densities of the two-dimensional narrow capture problem.

    PubMed

    Lindsay, A E; Spoonmore, R T; Tzou, J C

    2016-10-01

    A hybrid asymptotic-numerical method is presented for obtaining an asymptotic estimate for the full probability distribution of capture times of a random walker by multiple small traps located inside a bounded two-dimensional domain with a reflecting boundary. As motivation for this study, we calculate the variance in the capture time of a random walker by a single interior trap and determine this quantity to be comparable in magnitude to the mean. This implies that the mean is not necessarily reflective of typical capture times and that the full density must be determined. To solve the underlying diffusion equation, the method of Laplace transforms is used to obtain an elliptic problem of modified Helmholtz type. In the limit of vanishing trap sizes, each trap is represented as a Dirac point source that permits the solution of the transform equation to be represented as a superposition of Helmholtz Green's functions. Using this solution, we construct asymptotic short-time solutions of the first-passage-time density, which captures peaks associated with rapid capture by the absorbing traps. When numerical evaluation of the Helmholtz Green's function is employed followed by numerical inversion of the Laplace transform, the method reproduces the density for larger times. We demonstrate the accuracy of our solution technique with a comparison to statistics obtained from a time-dependent solution of the diffusion equation and discrete particle simulations. In particular, we demonstrate that the method is capable of capturing the multimodal behavior in the capture time density that arises when the traps are strategically arranged. The hybrid method presented can be applied to scenarios involving both arbitrary domains and trap shapes.

  13. A problem-based learning curriculum for occupational therapy education.

    PubMed

    Royeen, C B

    1995-04-01

    To prepare practitioners and researchers who are well equipped to deal with the inevitable myriad changes in health care and in society coming in the 21st century, a new focus is needed in occupational therapy education. In addition to proficiency in clinical skills and technical knowledge, occupational therapy graduates will need outcome competencies underlying the skills of critical reflection. In this article, the author presents (a) the rationale for the need for change in occupational therapy education, (b) key concepts of clinical reasoning and critical reflection pertaining to the outcome such change in occupational therapy education should address, (c) problem-based learning as a process and educational method to prepare occupational therapists in these competencies, and (d) the experience of the Program in Occupational Therapy at Shenandoah University in Winchester, Virginia, in implementing a problem-based learning curriculum.

  14. A controlled trial of trauma-focused therapy versus problem-solving in Islamic children affected by civil conflict and disaster in Aceh, Indonesia.

    PubMed

    Dawson, Katie; Joscelyne, Amy; Meijer, Catherine; Steel, Zachary; Silove, Derrick; Bryant, Richard A

    2018-03-01

    To evaluate the relative efficacies of trauma-focused cognitive behavior therapy and problem-solving therapy in treating post-traumatic stress disorder in children affected by civil conflict in Aceh, Indonesia. A controlled trial of children with post-traumatic stress disorder ( N = 64) randomized children to either five individual weekly sessions of trauma-focused cognitive behavior therapy or problem-solving therapy provided by lay-counselors who were provided with brief training. Children were assessed by blind independent assessors at pretreatment, posttreatment and 3-month follow-up on post-traumatic stress disorder, depression and anger, as well as caregiver ratings of the child's post-traumatic stress disorder levels. Intent-to-treat analyses indicated no significant linear time × treatment condition interaction effects for post-traumatic stress disorder at follow-up ( t(129.05) = -0.55, p = 0.58), indicating the two conditions did not differ. Across both conditions, there were significant reductions in post-traumatic stress disorder on self-reported ( t(131.26) = -9.26, p < 0.001) and caregiver-reported ( t(170.65) = 3.53, p = 0.001) measures and anger ( t(127.66) = -7.14, p < 0.001). Across both conditions, there was a large effect size for self-reported post-traumatic stress disorder (cognitive behavior therapy: 3.73, 95% confidence interval = [2.75, 3.97]; problem-solving: 2.68, 95% confidence interval = [2.07, 3.29]). These findings suggest that trauma-focused cognitive behavior therapy and problem-solving approaches are comparably successful in reducing post-traumatic stress disorder and anger in treating mental health in children in a post-conflict setting. This pattern may reflect the benefits of non-specific therapy effects or gains associated with trauma-focused or problem-solving approaches.

  15. A study on the optimum fast neutron flux for boron neutron capture therapy of deep-seated tumors.

    PubMed

    Rasouli, Fatemeh S; Masoudi, S Farhad

    2015-02-01

    High-energy neutrons, named fast neutrons which have a number of undesirable biological effects on tissue, are a challenging problem in beam designing for Boron Neutron Capture Therapy, BNCT. In spite of this fact, there is not a widely accepted criterion to guide the beam designer to determine the appropriate contribution of fast neutrons in the spectrum. Although a number of researchers have proposed a target value for the ratio of fast neutron flux to epithermal neutron flux, it can be shown that this criterion may not provide the optimum treatment condition. This simulation study deals with the determination of the optimum contribution of fast neutron flux in the beam for BNCT of deep-seated tumors. Since the dose due to these high-energy neutrons damages shallow tissues, delivered dose to skin is considered as a measure for determining the acceptability of the designed beam. To serve this purpose, various beam shaping assemblies that result in different contribution of fast neutron flux are designed. The performances of the neutron beams corresponding to such configurations are assessed in a simulated head phantom. It is shown that the previously used criterion, which suggests a limit value for the contribution of fast neutrons in beam, does not necessarily provide the optimum condition. Accordingly, it is important to specify other complementary limits considering the energy of fast neutrons. By analyzing various neutron spectra, two limits on fast neutron flux are proposed and their validity is investigated. The results show that considering these limits together with the widely accepted IAEA criteria makes it possible to have a more realistic assessment of sufficiency of the designed beam. Satisfying these criteria not only leads to reduction of delivered dose to skin, but also increases the advantage depth in tissue and delivered dose to tumor during the treatment time. The Monte Carlo Code, MCNP-X, is used to perform these simulations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Boron neutron capture therapy (BNCT) for glioblastoma multiforme: a phase II study evaluating a prolonged high-dose of boronophenylalanine (BPA).

    PubMed

    Henriksson, Roger; Capala, Jacek; Michanek, Annika; Lindahl, Sten-Ake; Salford, Leif G; Franzén, Lars; Blomquist, Erik; Westlin, Jan-Erik; Bergenheim, A Tommy

    2008-08-01

    To evaluate the efficacy and safety of boron neutron capture therapy (BNCT) for glioblastoma multiforme (GBM) using a novel protocol for the boronophenylalanine-fructose (BPA-F) infusion. This phase II study included 30 patients, 26-69 years old, with a good performance status of which 27 have undergone debulking surgery. BPA-F (900 mg BPA/kg body weight) was given i.v. over 6h. Neutron irradiation started 2h after the completion of the infusion. Follow-up reports were monitored by an independent clinical research institute. The boron-blood concentration during irradiation was 15.2-33.7 microg/g. The average weighted absorbed dose to normal brain was 3.2-6.1 Gy (W). The minimum dose to the tumour volume ranged from 15.4 to 54.3 Gy (W). Seven patients suffered from seizures, 8 from skin/mucous problem, 5 patients were stricken by thromboembolism and 4 from abdominal disturbances in close relation to BNCT. Four patients displayed 9 episodes of grade 3-4 events (WHO). At the time for follow-up, minimum ten months, 23 out of the 29 evaluable patients were dead. The median time from BNCT treatment to tumour progression was 5.8 months and the median survival time after BNCT was 14.2 months. Following progression, 13 patients were given temozolomide, two patients were re-irradiated, and two were re-operated. Patients treated with temozolomide lived considerably longer (17.7 vs. 11.6 months). The quality of life analysis demonstrated a progressive deterioration after BNCT. Although, the efficacy of BNCT in the present protocol seems to be comparable with conventional radiotherapy and the treatment time is shorter, the observed side effects and the requirement of complex infrastructure and higher resources emphasize the need of further phase I and II studies, especially directed to improve the accumulation of (10)B in tumour cells.

  17. High-power electron beam tests of a liquid-lithium target and characterization study of (7)Li(p,n) near-threshold neutrons for accelerator-based boron neutron capture therapy.

    PubMed

    Halfon, S; Paul, M; Arenshtam, A; Berkovits, D; Cohen, D; Eliyahu, I; Kijel, D; Mardor, I; Silverman, I

    2014-06-01

    A compact Liquid-Lithium Target (LiLiT) was built and tested with a high-power electron gun at Soreq Nuclear Research Center (SNRC). The target is intended to demonstrate liquid-lithium target capabilities to constitute an accelerator-based intense neutron source for Boron Neutron Capture Therapy (BNCT) in hospitals. The lithium target will produce neutrons through the (7)Li(p,n)(7)Be reaction and it will overcome the major problem of removing the thermal power >5kW generated by high-intensity proton beams, necessary for sufficient therapeutic neutron flux. In preliminary experiments liquid lithium was flown through the target loop and generated a stable jet on the concave supporting wall. Electron beam irradiation demonstrated that the liquid-lithium target can dissipate electron power densities of more than 4kW/cm(2) and volumetric power density around 2MW/cm(3) at a lithium flow of ~4m/s, while maintaining stable temperature and vacuum conditions. These power densities correspond to a narrow (σ=~2mm) 1.91MeV, 3mA proton beam. A high-intensity proton beam irradiation (1.91-2.5MeV, 2mA) is being commissioned at the SARAF (Soreq Applied Research Accelerator Facility) superconducting linear accelerator. In order to determine the conditions of LiLiT proton irradiation for BNCT and to tailor the neutron energy spectrum, a characterization of near threshold (~1.91MeV) (7)Li(p,n) neutrons is in progress based on Monte-Carlo (MCNP and Geant4) simulation and on low-intensity experiments with solid LiF targets. In-phantom dosimetry measurements are performed using special designed dosimeters based on CR-39 track detectors. © 2013 Elsevier Ltd. All rights reserved.

  18. Development and application of a mark-recapture model incorporating predicted sex and transitory behaviour

    USGS Publications Warehouse

    Conroy, M.J.; Senar, J.C.; Hines, J.E.; Domenech, J.

    1999-01-01

    We developed an extension of Cormack-Jolly-Seber models to handle a complex mark-recapture problem in which (a) the sex of birds cannot be determined prior to first moult, but can be predicted on the basis of body measurements, and (b) a significant portion of captured birds appear to be transients (i.e. are captured once but leave the area or otherwise become ' untrappable'). We applied this methodology to a data set of 4184 serins (Serinus serinus) trapped in northeastern Spain during 1985-96, in order to investigate age-, sex-, and time-specific variation in survival rates. Using this approach, we were able to successfully incorporate the majority of ringings of serins. Had we eliminated birds not previously captured (as has been advocated to avoid the problem of transience) we would have reduced our sample sizes by >2000 releases. In addition, we were able to include 1610 releases of birds of unknown (but predicted) sex; these data contributed to the precision of our estimates and the power of statistical tests. We discuss problems with data structure, encoding of the algorithms to compute parameter estimates, model selection, identifiability of parameters, and goodness-of-fit, and make recommendations for the design and analysis of future studies facing similar problems.

  19. Development and application of a mark-recapture model incorporating predicted sex and transitory behaviour

    USGS Publications Warehouse

    Conroy, M.J.; Senar, J.C.; Hines, J.E.; Domenech, J.

    1999-01-01

    We developed an extension of Cormack-Jolly-Seber models to handle a complex mark-recapture problem in which (a) the sex of birds cannot be determined prior to first moult, but can be predicted on the basis of body measurements, and (b) a significant portion of captured birds appear to be transients (i.e. are captured once but leave the area or otherwise become 'untrappable'). We applied this methodology to a data set of 4184 serins (Serinus serinus) trapped in northeastern Spain during 1985-96, in order to investigate age-, sex-, and time-specific variation in survival rates. Using this approach, we were able to successfully incorporate the majority of ringings of serins. Had we eliminated birds not previously captured (as has been advocated to avoid the problem of transience) we would have reduced our sample sizes by >2000 releases. In addition, we were able to include 1610 releases of birds of unknown (but predicted) sex; these data contributed to the precision of our estimates and the power of statistical tests. We discuss problems with data structure, encoding of the algorithms to compute parameter estimates, model selection, identifiability of parameters, and goodness-of-fit, and make recommendations for the design and analysis of future studies facing similar problems.

  20. Factors influencing the variation in capture rates of shrews in southern California, USA

    USGS Publications Warehouse

    Laakkonen, Juha; Fisher, Robert N.; Case, Ted J.

    2003-01-01

    We examined the temporal variation in capture rates of shrewsNotiosorex crawfordi (Coues, 1877) and Sorex ornatus (Merriam, 1895) in 20 sites representing fragmented and continuous habitats in southern California, USA. InN. crawfordi, the temporal variation was significantly correlated with the mean capture rates. Of the 6 landscape variables analyzed (size of the landscape, size of the sample area, altitude, edge, longitude and latitude), sample area was positively correlated with variation in capture rates ofN. crawfordi. InS. ornatus, longitude was negatively correlated with variation in capture rates. Analysis of the effect of precipitation on the short- and long-term capture rates at 2 of the sites showed no correlation between rainfall and capture rates of shrews even though peak number of shrews at both sites were reached during the year of highest amount of rainfall. A key problem confounding capture rates of shrews in southern California is the low overall abundance of both shrew species in all habitats and seasons.

  1. The roles of the Q (q) wave in lead I and QRS frontal axis for diagnosing loss of left ventricular capture during cardiac resynchronization therapy.

    PubMed

    Cao, Yuan-Yuan; Su, Yan-Gang; Bai, Jin; Wang, Wei; Wang, Jing-Feng; Qin, Sheng-Mei; Ge, Jun-Bo

    2015-01-01

    Loss of left ventricular (LV) capture may lead to deterioration of heart failure in patients with cardiac resynchronization therapy (CRT). Recognition of loss of LV capture in time is important in clinical practice. A total of 422 electrocardiograms were acquired and analyzed from 53 CRT patients at 8 different pacing settings (LV only, right ventricle [RV] only, biventricular [BV] pacing with LV preactivation of 60, 40, 20, and 0 milliseconds and RV preactivation of 20 and 40 milliseconds). A modified Ammann algorithm by adding a third step-presence of Q (q, or QS) wave-to the original 2-step Ammann algorithm and a QRS axis shift method were devised to identify the loss of LV capture. The accuracy of modified Ammann algorithm was significantly higher than that of Ammann algorithm (78.9% vs. 69.1%, P < 0.001). The accuracy of the axis shift method was 66.4%, which was significantly lower than the modified Ammann algorithm (P < 0.001) and similar to the original one (P = 0.412). However, in the ECGs with QRS axis shift, 96.8% were correctly classified. LV preactivation or simultaneous BV activation and LV lead positioned in nonposterior or noninferior wall could elevate the accuracies of the modified Ammann algorithm and the QRS axis shift method. The accuracy of the modified Ammann algorithm is greatly improved. The QRS axis shift method can help diagnose LV capture. The LV preactivation, or simultaneous BV activation and LV lead positioned in nonposterior or noninferior wall can increase the diagnostic power of the modified Ammann algorithm and QRS axis shift method. © 2014 Wiley Periodicals, Inc.

  2. Use of regularized principal component analysis to model anatomical changes during head and neck radiation therapy for treatment adaptation and response assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chetvertkov, Mikhail A., E-mail: chetvertkov@wayne

    2016-10-15

    Purpose: To develop standard (SPCA) and regularized (RPCA) principal component analysis models of anatomical changes from daily cone beam CTs (CBCTs) of head and neck (H&N) patients and assess their potential use in adaptive radiation therapy, and for extracting quantitative information for treatment response assessment. Methods: Planning CT images of ten H&N patients were artificially deformed to create “digital phantom” images, which modeled systematic anatomical changes during radiation therapy. Artificial deformations closely mirrored patients’ actual deformations and were interpolated to generate 35 synthetic CBCTs, representing evolving anatomy over 35 fractions. Deformation vector fields (DVFs) were acquired between pCT and syntheticmore » CBCTs (i.e., digital phantoms) and between pCT and clinical CBCTs. Patient-specific SPCA and RPCA models were built from these synthetic and clinical DVF sets. EigenDVFs (EDVFs) having the largest eigenvalues were hypothesized to capture the major anatomical deformations during treatment. Results: Principal component analysis (PCA) models achieve variable results, depending on the size and location of anatomical change. Random changes prevent or degrade PCA’s ability to detect underlying systematic change. RPCA is able to detect smaller systematic changes against the background of random fraction-to-fraction changes and is therefore more successful than SPCA at capturing systematic changes early in treatment. SPCA models were less successful at modeling systematic changes in clinical patient images, which contain a wider range of random motion than synthetic CBCTs, while the regularized approach was able to extract major modes of motion. Conclusions: Leading EDVFs from the both PCA approaches have the potential to capture systematic anatomical change during H&N radiotherapy when systematic changes are large enough with respect to random fraction-to-fraction changes. In all cases the RPCA approach appears to be more reliable at capturing systematic changes, enabling dosimetric consequences to be projected once trends are established early in a treatment course, or based on population models.« less

  3. Research on Capturing of Customer Requirements Based on Innovation Theory

    NASA Astrophysics Data System (ADS)

    junwu, Ding; dongtao, Yang; zhenqiang, Bao

    To exactly and effectively capture customer requirements information, a new customer requirements capturing modeling method was proposed. Based on the analysis of function requirement models of previous products and the application of technology system evolution laws of the Theory of Innovative Problem Solving (TRIZ), the customer requirements could be evolved from existing product designs, through modifying the functional requirement unit and confirming the direction of evolution design. Finally, a case study was provided to illustrate the feasibility of the proposed approach.

  4. Assessment of numerical methods for the solution of fluid dynamics equations for nonlinear resonance systems

    NASA Technical Reports Server (NTRS)

    Przekwas, A. J.; Yang, H. Q.

    1989-01-01

    The capability of accurate nonlinear flow analysis of resonance systems is essential in many problems, including combustion instability. Classical numerical schemes are either too diffusive or too dispersive especially for transient problems. In the last few years, significant progress has been made in the numerical methods for flows with shocks. The objective was to assess advanced shock capturing schemes on transient flows. Several numerical schemes were tested including TVD, MUSCL, ENO, FCT, and Riemann Solver Godunov type schemes. A systematic assessment was performed on scalar transport, Burgers' and gas dynamic problems. Several shock capturing schemes are compared on fast transient resonant pipe flow problems. A system of 1-D nonlinear hyperbolic gas dynamics equations is solved to predict propagation of finite amplitude waves, the wave steepening, formation, propagation, and reflection of shocks for several hundred wave cycles. It is shown that high accuracy schemes can be used for direct, exact nonlinear analysis of combustion instability problems, preserving high harmonic energy content for long periods of time.

  5. Capture of Planetesimals into a Circumterrestrial Swarm

    NASA Technical Reports Server (NTRS)

    Weidenschilling, S. J.

    1985-01-01

    The lunar origin model considered in this report involves processing of protolunar material through a circumterrestrial swarm of particles. Once such a swarm has formed, it can gain mass by capturing infalling planetesimals and ejecta from giant impacts on the Earth, although the angular momentum supply from these sources remains a problem. The first stage of formation of a geocentric swarm by capture of planetesimals from initially heliocentric orbits is examined. The only plausible capture mechanism that is not dependent on very low approach velocities is the mutual collision of planetesimals passing within Earth's sphere of influence. The dissipation of energy in inelastic collisions or accretion events changes the value of the Jacobi parameter, allowing capture into bound geocentric orbits. This capture scenario was tested directly by many body numerical integration of planetesimal orbits in near Earth space.

  6. Algorithm For Hypersonic Flow In Chemical Equilibrium

    NASA Technical Reports Server (NTRS)

    Palmer, Grant

    1989-01-01

    Implicit, finite-difference, shock-capturing algorithm calculates inviscid, hypersonic flows in chemical equilibrium. Implicit formulation chosen because overcomes limitation on mathematical stability encountered in explicit formulations. For dynamical portion of problem, Euler equations written in conservation-law form in Cartesian coordinate system for two-dimensional or axisymmetric flow. For chemical portion of problem, equilibrium state of gas at each point in computational grid determined by minimizing local Gibbs free energy, subject to local conservation of molecules, atoms, ions, and total enthalpy. Major advantage: resulting algorithm naturally stable and captures strong shocks without help of artificial-dissipation terms to damp out spurious numerical oscillations.

  7. Hydrogen fluoride capture by imidazolium acetate ionic liquid

    NASA Astrophysics Data System (ADS)

    Chaban, Vitaly

    2015-04-01

    Extraction of hydrofluoric acid (HF) from oils is a drastically important problem in petroleum industry, since HF causes quick corrosion of pipe lines and brings severe health problems to humanity. Some ionic liquids (ILs) constitute promising scavenger agents thanks to strong binding to polar compounds and tunability. PM7-MD simulations and hybrid density functional theory are employed here to consider HF capture ability of ILs. Discussing the effects and impacts of the cation and the anion separately and together, we evaluate performance of imidazolium acetate and outline systematic search guidelines for efficient adsorption and extraction of HF.

  8. Fast Sampling Gas Chromatography (GC) System for Speciation in a Shock Tube

    DTIC Science & Technology

    2016-10-31

    capture similar ethylene decomposition rates for temperature-dependent shock experiments. (a) Papers published in peer-reviewed journals (N/A for none...3 GC Sampling System Validation Experiments ............................................................................... 5 Ethylene ...results for cold shock experiments, and both techniques capture similar ethylene decomposition rates for temperature-dependent shock experiments. Problem

  9. Interactive Drawing Therapy and Chinese Migrants with Gambling Problems

    ERIC Educational Resources Information Center

    Zhang, Wenli; Everts, Hans

    2012-01-01

    Ethnic Chinese migrants in a country like New Zealand face a range of well-documented challenges. A proportion of such migrants find that recreational gambling turns into a pernicious gambling problem. This issue is addressed through illustrated case studies of Interactive Drawing Therapy, a drawing-based modality of therapy that facilitates…

  10. Treatment Adherence, Competence, and Outcome in Individual and Family Therapy for Adolescent Behavior Problems

    ERIC Educational Resources Information Center

    Hogue, Aaron; Henderson, Craig E.; Dauber, Sarah; Barajas, Priscilla C.; Fried, Adam; Liddle, Howard A.

    2008-01-01

    This study examined the impact of treatment adherence and therapist competence on treatment outcome in a controlled trial of individual cognitive-behavioral therapy (CBT) and multidimensional family therapy (MDFT) for adolescent substance use and related behavior problems. Participants included 136 adolescents (62 CBT, 74 MDFT) assessed at intake,…

  11. Comparison of Family Therapy Outcome with Alcohol-Abusing, Runaway Adolescents

    ERIC Educational Resources Information Center

    Slesnick, Natasha; Prestopnik, Jillian L

    2009-01-01

    Treatment evaluation for alcohol problem, runaway adolescents and their families is rare. This study recruited primary alcohol problem adolescents (N = 119) and their primary caretakers from two runaway shelters and assigned them to (a) home-based ecologically based family therapy (EBFT), (b) office-based functional family therapy (FFT), or (c)…

  12. Family Psychology and Family Therapy in Japan.

    ERIC Educational Resources Information Center

    Kameguchi, Kenji; Murphy-Shigematsu, Stephen

    2001-01-01

    Reviews the development of family psychology and family therapy in Japan, tracing the origins of these movements, explaining how these fields were activated by the problem of school refusal, and describing an approach to family therapy that has been developed to work with families confronting this problem, as well as preventive programs of family…

  13. The impact of group therapy training on social communications of Afghan immigrants

    PubMed Central

    Mehrabi, Tayebeh; Musavi, Tayebeh; Ghazavi, Zahra; Zandieh, Zahra; Zamani, Ahmadreza

    2011-01-01

    BACKGROUND: Mental training considers sharing of mental health care information as the primary objective. The secondary objectives include facilitating dialogue about feelings such as isolation, sadness, labeling, loneliness and possible strategies for confronting with these feelings. Group therapy trainings have supportive functioning in accepting the environment so that the members are able to be part of the indigenous groups. However, no study has been ever done on the impact of this educational method on the communication problems of this group. This study aimed to determine the impact of group therapy training on the communication problems of Afghan immigrants. METHODS: This was a clinical trial study. Eighty-eight Afghan men were investigated. Sampling method was simple sampling method. Thereafter, the study subjects were divided randomly into two groups of test and control based on the inclusion criteria. Data collection tool was a self-made questionnaire about the social problems. For analyzing the data, software SPSS, independent t-test and paired t-test were used. RESULTS: Reviewing the data indicated lower mean score of the social problems after implementing the group therapy training in social communication compared with before implementing the group therapy training. Paired t-test showed a significant difference between mean scores of the social communication problems before and after the implementation of group therapy training. CONCLUSIONS: Given the effectiveness of the intervention, group therapy training on social problems in social communication of Afghan immigrants is recommended. This program should be part of continuous education and training of the Afghan immigrants. PMID:22224098

  14. The problem of latent attentional capture: Easy visual search conceals capture by task-irrelevant abrupt onsets.

    PubMed

    Gaspelin, Nicholas; Ruthruff, Eric; Lien, Mei-Ching

    2016-08-01

    Researchers are sharply divided regarding whether irrelevant abrupt onsets capture spatial attention. Numerous studies report that they do and a roughly equal number report that they do not. This puzzle has inspired numerous attempts at reconciliation, none gaining general acceptance. The authors propose that abrupt onsets routinely capture attention, but the size of observed capture effects depends critically on how long attention dwells on distractor items which, in turn, depends critically on search difficulty. In a series of spatial cuing experiments, the authors show that irrelevant abrupt onsets produce robust capture effects when visual search is difficult, but not when search is easy. Critically, this effect occurs even when search difficulty varies randomly across trials, preventing any strategic adjustments of the attentional set that could modulate probability of capture by the onset cue. The authors argue that easy visual search provides an insensitive test for stimulus-driven capture by abrupt onsets: even though onsets truly capture attention, the effects of capture can be latent. This observation helps to explain previous failures to find capture by onsets, nearly all of which used an easy visual search. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  15. The Problem of Latent Attentional Capture: Easy Visual Search Conceals Capture by Task-Irrelevant Abrupt Onsets

    PubMed Central

    Gaspelin, Nicholas; Ruthruff, Eric; Lien, Mei-Ching

    2016-01-01

    Researchers are sharply divided regarding whether irrelevant abrupt onsets capture spatial attention. Numerous studies report that they do and a roughly equal number report that they do not. This puzzle has inspired numerous attempts at reconciliation, none gaining general acceptance. We propose that abrupt onsets routinely capture attention, but the size of observed capture effects depends critically on how long attention dwells on distractor items which, in turn, depends critically on search difficulty. In a series of spatial cuing experiments, we show that irrelevant abrupt onsets produce robust capture effects when visual search is difficult, but not when search is easy. Critically, this effect occurs even when search difficulty varies randomly across trials, preventing any strategic adjustments of the attentional set that could modulate probability of capture by the onset cue. We argue that easy visual search provides an insensitive test for stimulus-driven capture by abrupt onsets: even though onsets truly capture attention, the effects of capture can be latent. This observation helps to explain previous failures to find capture by onsets, nearly all of which employed an easy visual search. PMID:26854530

  16. Gadolinium diethylenetriaminopentaacetic acid-loaded chitosan microspheres for gadolinium neutron-capture therapy.

    PubMed

    Saha, Tapan Kumar; Ichikawa, Hideki; Fukumori, Yoshinobu

    2006-12-11

    In order to provide a suitable device that would contain water-soluble drugs, highly water-soluble gadolinium diethylenetriaminopentaacetic acid-loaded chitosan microspheres (CMS-Gd-DTPA) were prepared by the emulsion method using glutaraldehyde as a cross-linker and Span 80 as a surfactant for gadolinium neutron-capture therapy of cancer. The gadolinium content and the mass median diameter of CMS-Gd-DTPA were estimated. The size and morphology of the CMS-Gd-DTPA were strongly influenced by the initial applied weight ratio of Gd-DTPA:chitosan. FTIR spectra showed that the electrostatic interaction between chitosan and Gd-DTPA accelerated the formation of gadolinium-enriched chitosan microspheres. Sufficient amounts of glutaraldehyde and Span 80 were necessary for producing discrete CMS-Gd-DTPA. The CMS-Gd-DTPA having a mass median diameter 11.7microm and 11.6% of gadolinium could be used in Gd-NCT following intratumoral injection.

  17. Carboranylporphyrins and uses thereof

    DOEpatents

    Miura, Michiko; Renner, Mark W

    2012-10-16

    The present invention is directed to low toxicity boronated compounds and methods for their use in the treatment, visualization, and diagnosis of tumors. More specifically, the present invention is directed to low toxicity carborane-containing porphyrin compounds with halide, amine, or nitro groups and methods for their use particularly in boron neutron capture therapy (BNCT), X-ray radiation therapy (XRT), and photodynamic therapy (PDT) for the treatment of tumors of the brain, head and neck, and surrounding tissue. The invention is also directed to using these carborane-containing porphyrin compounds in methods of tumor imaging and/or diagnosis such as MRI, SPECT, or PET.

  18. Carbonylporphyrins and uses thereof

    DOEpatents

    Miura, Michiko; Renner, Mark W

    2014-03-18

    The present invention is directed to low toxicity boronated compounds and methods for their use in the treatment, visualization, and diagnosis of tumors. More specifically, the present invention is directed to low toxicity carborane-containing porphyrin compounds with halide, amine, or nitro groups and methods for their use particularly in boron neutron capture therapy (BNCT), X-ray radiation therapy (XRT), and photodynamic therapy (PDT) for the treatment of tumors of the brain, head and neck, and surrounding tissue. The invention is also directed to using these carborane-containing porphyrin compounds in methods of tumor imaging and/or diagnosis such as MRI, SPECT, or PET.

  19. 3DUI assisted lower and upper member therapy.

    PubMed

    Uribe-Quevedo, Alvaro; Perez-Gutierrez, Byron

    2012-01-01

    3DUIs are becoming very popular among researchers, developers and users as they allow more immersive and interactive experiences by taking advantage of the human dexterity. The features offered by these interfaces outside the gaming environment, have allowed the development of applications in the medical area by enhancing the user experience and aiding the therapy process in controlled and monitored environments. Using mainstream videogame 3DUIs based on inertial and image sensors available in the market, this work presents the development of a virtual environment and its navigation through lower member captured gestures for assisting motion during therapy.

  20. Liposome-based delivery of a boron-containing cholesteryl ester for high-LET particle-induced damage of prostate cancer cells: a boron neutron capture therapy study.

    PubMed

    Gifford, Ian; Vreeland, Wyatt; Grdanovska, Slavica; Burgett, Eric; Kalinich, John; Vergara, Vernieda; Wang, C-K Chris; Maimon, Eric; Poster, Dianne; Al-Sheikhly, Mohamad

    2014-06-01

    The efficacy of a boron-containing cholesteryl ester compound (BCH) as a boron neutron capture therapy (BNCT) agent for the targeted irradiation of PC-3 human prostate cancer cells was examined. Liposome-based delivery of BCH was quantified with inductively coupled plasma-mass spectrometry (ICP-MS) and high-performance liquid chromatography (HPLC). Cytotoxicity of the BCH-containing liposomes was evaluated with neutral red, 3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium (MTS), and lactate dehydrogenase assays. Colony formation assays were utilized to evaluate the decrease in cell survival due to high-linear energy transfer (LET) particles resulting from (10)B thermal neutron capture. BCH delivery by means of encapsulation in a lipid bilayer resulted in a boron uptake of 35.2 ± 4.3 μg/10(9) cells, with minimal cytotoxic effects. PC-3 cells treated with BCH and exposed to a 9.4 × 10(11) n/cm(2) thermal neutron fluence yielded a 20-25% decrease in clonogenic capacity. The decreased survival is attributed to the generation of high-LET α particles and (7)Li nuclei that deposit energy in densely ionizing radiation tracks. Liposome-based delivery of BCH is capable of introducing sufficient boron to PC-3 cells for BNCT. High-LET α particles and (7)Li nuclei generated from (10)B thermal neutron capture significantly decrease colony formation ability in the targeted PC-3 cells.

  1. Dynamics and control of robot for capturing objects in space

    NASA Astrophysics Data System (ADS)

    Huang, Panfeng

    Space robots are expected to perform intricate tasks in future space services, such as satellite maintenance, refueling, and replacing the orbital replacement unit (ORU). To realize these missions, the capturing operation may not be avoided. Such operations will encounter some challenges because space robots have some unique characteristics unfound on ground-based robots, such as, dynamic singularities, dynamic coupling between manipulator and space base, limited energy supply and working without a fixed base, and so on. In addition, since contacts and impacts may not be avoided during capturing operation. Therefore, dynamics and control problems of space robot for capturing objects are significant research topics if the robots are to be deployed for the space services. A typical servicing operation mainly includes three phases: capturing the object, berthing and docking the object, then repairing the target. Therefore, this thesis will focus on resolving some challenging problems during capturing the object, berthing and docking, and so on. In this thesis, I study and analyze the dynamics and control problems of space robot for capturing objects. This work has potential impact in space robotic applications. I first study the contact and impact dynamics of space robot and objects. I specifically focus on analyzing the impact dynamics and mapping the relationship of influence and speed. Then, I develop the fundamental theory for planning the minimum-collision based trajectory of space robot and designing the configuration of space robot at the moment of capture. To compensate for the attitude of the space base during the capturing approach operation, a new balance control concept which can effectively balance the attitude of the space base using the dynamic couplings is developed. The developed balance control concept helps to understand of the nature of space dynamic coupling, and can be readily applied to compensate or minimize the disturbance to the space base. After capturing the object, the space robot must complete the following two tasks: one is to berth the object, and the other is to re-orientate the attitude of the whole robot system for communication and power supply. Therefore, I propose a method to accomplish these two tasks simultaneously using manipulator motion only. The ultimate goal of space services is to realize the capture and manipulation autonomously. Therefore, I propose an affective approach based on learning human skill to track and capture the objects automatically in space. With human-teaching demonstration, the space robot is able to learn and abstract human tracking and capturing skill using an efficient neural-network learning architecture that combines flexible Cascade Neural Networks with Node Decoupled Extended Kalman Filtering (CNN-NDEKF). The simulation results attest that this approach is useful and feasible in tracking trajectory planning and capturing of space robot. Finally I propose a novel approach based on Genetic Algorithms (GAs) to optimize the approach trajectory of space robots in order to realize effective and stable operations. I complete the minimum-torque path planning in order to save the limited energy in space, and design the minimum jerk trajectory for the stabilization of the space manipulator and its space base. These optimal algorithms are very important and useful for the application of space robot.

  2. A simple level set method for solving Stefan problems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, S.; Merriman, B.; Osher, S.

    1997-07-15

    Discussed in this paper is an implicit finite difference scheme for solving a heat equation and a simple level set method for capturing the interface between solid and liquid phases which are used to solve Stefan problems.

  3. Intrathecal baclofen therapy in paediatrics: a study protocol for an Australian multicentre, 10-year prospective audit.

    PubMed

    Stewart, Kirsty; Hutana, Gavin; Kentish, Megan

    2017-06-21

    Increasing clinical use of Intrathecal baclofen (ITB) in Australian tertiary paediatric hospitals, along with the need for standardised assessment and reporting of adverse events, saw the formation of the Australian Paediatric ITB Research Group (APIRG). APIRG developed a National ITB Audit tool designed to capture clinical outcomes and adverse events data for all Australian children and adolescents receiving ITB therapy. The Australian ITB Audit is a 10 year, longitudinal, prospective, clinical audit collecting all adverse events and assessment data across body functions and structure, participation and activity level domains of the ICF. Data will be collected at baseline, 6 and 12 months with ongoing capture of all adverse event data. This is the first Australian study that aims to capture clinical and adverse event data from a complete population of children with neurological impairment receiving a specific intervention between 2011 and 2021. This multi-centre study will inform ITB clinical practice in children and adolescents, direct patient selection, record and aid decision making regarding adverse events and investigate the impact of ITB therapy on family and patient quality of life. This project was approved by the individual Human Research Ethics committees at the six Australian tertiary hospitals involved in the study. Results will be published in various peer reviewed journals and presented at national and international conferences. ACTRN 12610000323022; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Patterns of Chemotherapy Use in a U.S.-Based Cohort of Patients with Metastatic Pancreatic Cancer.

    PubMed

    Abrams, Thomas A; Meyer, Gary; Meyerhardt, Jeffrey A; Wolpin, Brian M; Schrag, Deborah; Fuchs, Charles S

    2017-08-01

    Few population studies have examined patterns of systemic therapy administration in metastatic pancreatic cancer (MPC) or the predictors associated with specific treatment choices. We assessed 4,011 consecutive MPC patients who received chemotherapy between January 2005 and December 2015 at academic, private, and community-based oncology practices subscribing to a U.S.-wide chemotherapy order entry system capturing disease, patient, provider, and treatment data. Multivariate analyses of these prospectively recorded characteristics identified significant predictors of specific therapeutic choices. Overall, 100 different regimens were used in first-line treatment of MPC. First-line gemcitabine monotherapy usage fell steadily from 72% in 2006 to 16% in 2015. This steep decline mirrored increases in first-line usage of both 5 fluorouracil, leucovorin, irinotecan and oxaliplatin (FOLFIRINOX) and gemcitabine + nab-paclitaxel. Younger male patients were more likely to receive FOLFIRINOX as first-line treatment, whereas patients treated at community practices and by oncologists with lower MPC patient volume were more likely to receive gemcitabine plus nab-paclitaxel (all p  ≤ .05). Among all patients receiving first-line chemotherapy for MPC, 49% went on to receive second-line therapy and 19% received third-line therapy; administration of second- and third-line therapies increased steadily over the time course of follow-up. Younger patients and those treated by oncologists with higher MPC patient volume were more likely to receive second- and third-line therapies. This population-based study provides insight into treatment patterns of MPC in the U.S. Usage patterns varied greatly according to patient and provider characteristics. This study examined real world metastatic pancreatic cancer treatment patterns in the United States with the goals of understanding changes in chemotherapy treatment frequencies over time and determining the individual predictors that underlie the chemotherapy choices oncologists make for their patients. Our data set is unique in that it captured not only patient-level data, but also oncologist-level data. It also captured data from private and community practices as well as academic centers. To our knowledge, this is the only data set that can give this degree of insight into oncologist decision making practices. © AlphaMed Press 2017.

  5. The Practical Side of Working with Parent-Child Interaction Therapy with Preschool Children with Language Impairments

    ERIC Educational Resources Information Center

    Klatte, Inge S.; Roulstone, Sue

    2016-01-01

    A common early intervention approach for preschool children with language problems is parent-child interaction therapy (PCIT). PCIT has positive effects for children with expressive language problems. It appears that speech and language therapists (SLTs) conduct this therapy in many different ways. This might be because of the variety of…

  6. Witnessing Stories: Definitional Ceremonies in Narrative Therapy with Adults Who Stutter

    ERIC Educational Resources Information Center

    Leahy, Margaret M.; O'Dwyer, Mary; Ryan, Fiona

    2012-01-01

    Background: Narrative therapy (White & Epston, 1990) was developed as an approach to counselling, as a response to the power relations that influence people's lives. Its use with people who stutter has been documented. A basic tenet of narrative therapy is that the dominant problem-saturated narrative is challenged by externalizing the problem, in…

  7. Separating the Problem and the Person: Insights from Narrative Therapy with People Who Stutter

    ERIC Educational Resources Information Center

    Ryan, Fiona; O'Dwyer, Mary; Leahy, Margaret M.

    2015-01-01

    Stuttering is a complex disorder of speech that encompasses motor speech and emotional and cognitive factors. The use of narrative therapy is described here, focusing on the stories that clients tell about the problems associated with stuttering that they have encountered in their lives. Narrative therapy uses these stories to understand, analyze,…

  8. Meeting the expectations of chronic tinnitus patients: comparison of a structured group therapy program for tinnitus management with a problem-solving group.

    PubMed

    Wise, K; Rief, W; Goebel, G

    1998-06-01

    Two different group treatments were evaluated in 144 in-patients suffering from impairment due to chronic tinnitus. A tinnitus management therapy (TMT) was developed using principles of cognitive-behavioral therapy and compared with problem solving group therapy. Self-ratings were used to evaluate the help patients found in dealing with life problems and tinnitus as well as the degree to which they felt they were being properly treated and taken seriously. Patients showed significantly more satisfaction with the TMT group and evaluated the help they found in coping with tinnitus and life problems significantly higher. Thus, in the light of unsatisfactory medical solutions and the poor acceptance of some psychological treatments for tinnitus, TMT appears to be an acceptable and helpful treatment program.

  9. Problems Inhibiting Attentional Capture by Irrelevant Stimuli in Patients with Frontotemporal Dementia

    ERIC Educational Resources Information Center

    Piquard, Ambre; Lacomblez, Lucette; Derouesne, Christian; Sieroff, Eric

    2009-01-01

    We studied the role of the frontal lobes in orienting spatial attention and inhibiting attentional capture by goal-irrelevant stimuli, using a spatial cueing method in patients with frontotemporal dementia (FTD). Two blocks of trials were presented, one with non-predictive cues and the other with counter-predictive cues. FTD patients showed a…

  10. Boron neutron capture therapy for recurrent high-grade meningiomas.

    PubMed

    Kawabata, Shinji; Hiramatsu, Ryo; Kuroiwa, Toshihiko; Ono, Koji; Miyatake, Shin-Ichi

    2013-10-01

    Similar to glioblastomas, high-grade meningiomas are difficult pathologies to control. In this study, the authors used boron neutron capture therapy (BNCT), a tumor-selective intensive particle radiation modality, to treat high-grade meningioma. From June 2005 to September 2011, BNCT was applied 28 times in 20 cases of recurrent high-grade meningioma. All patients had previously undergone intensive treatments such as repetitive surgeries and multiple sessions of radiation therapy. Fluorine-18-labeled boronophenylalanine ((18)F-BPA) PET was performed before BNCT in 19 of the 20 cases; BPA is itself a therapeutic compound. Compound uptake, tumor shrinkage, long-term control rate including survival time, and failure pattern of the treated patients were all evaluated. Eighteen of 19 cases studied using (18)F-BPA PET showed good BPA uptake, with ratios of tumor to normal brain greater than 2.7. These ratios indicated the likely effects of BNCT prior to neutron irradiation. The original tumor sizes were between 4.3 cm(3) and 109 cm(3). A mean tumor volume reduction of 64.5% was obtained after BNCT within just 2 months. The median follow-up duration was 13 months. Six patients are still alive; at present, the median survival times after BNCT and diagnosis are 14.1 months (95% CI 8.6-40.4 months) and 45.7 months (95% CI 32.4-70.7 months), respectively. Clinical symptoms before BNCT, such as hemiparesis and facial pain, were improved after BNCT in symptomatic cases. Systemic metastasis, intracranial distant recurrence outside the radiation field, CSF dissemination, and local tumor progression were observed in 6, 7, 3, and 3 cases, respectively, during the clinical course. Apparent pseudoprogression was observed in at least 3 cases. Symptomatic radiation injuries occurred in 6 cases, and were controllable in all but 1 case. Boron neutron capture therapy may be especially effective in cases of high-grade meningioma.

  11. Dendrimer-based nanoparticles for cancer therapy.

    PubMed

    Baker, James R

    2009-01-01

    Recent work has suggested that nanoparticles in the form of dendrimers may be a keystone in the future of therapeutics. The field of oncology could soon be revolutionized by novel strategies for diagnosis and therapy employing dendrimer-based nanotherapeutics. Several aspects of cancer therapy would be involved. Diagnosis using imaging techniques such as MRI will be improved by the incorporation of dendrimers as advanced contrast agents. This might involve novel contrast agents targeted specifically to cancer cells. Dendrimers can also be being applied to a variety of cancer therapies to improve their safety and efficacy. A strategy, somewhat akin to the "Trojan horse," involves targeting anti-metabolite drugs via vitamins or hormones that tumors need for growth. Further applications of dendrimers in photodynamic therapy, boron neutron capture therapy, and gene therapy for cancer are being examined. This presentation will cover the fundamentals of research utilizing dendrimers for cancer diagnosis and therapy. An evaluation of this new technologies will detail what advantage dendrimer based therapeutics might have over conventional cancer drugs.

  12. Sarcopenia during neoadjuvant therapy for oesophageal cancer: characterising the impact on muscle strength and physical performance.

    PubMed

    Guinan, Emer M; Doyle, S L; Bennett, A E; O'Neill, L; Gannon, J; Elliott, J A; O'Sullivan, J; Reynolds, J V; Hussey, J

    2018-05-01

    Preoperative chemo(radio)therapy for oesophageal cancer (OC) may have an attritional impact on body composition and functional status, impacting postoperative outcome. Physical decline with skeletal muscle loss has not been previously characterised in OC and may be amenable to physical rehabilitation. This study characterises skeletal muscle mass and physical performance from diagnosis to post-neoadjuvant therapy in patients undergoing preoperative chemo(radio)therapy for OC. Measures of body composition (axial computerised tomography), muscle strength (handgrip), functional capacity (walking distance), anthropometry (weight, height and waist circumference), physical activity, quality-of-life and nutritional status were captured prospectively. Sarcopenia status was defined as pre-sarcopenic (low muscle mass only), sarcopenic (low muscle mass and low muscle strength or function) or severely sarcopenic (low muscle mass and low muscle strength and low muscle function). Twenty-eight participants were studied at both time points (mean age 62.86 ± 8.18 years, n = 23 male). Lean body mass reduced by 4.9 (95% confidence interval 3.2 to 6.7) kg and mean grip strength reduced by 4.3 (2.5 to 6.1) kg from pre- to post-neoadjuvant therapy. Quality-of-life scores capturing gastrointestinal symptoms improved. Measures of anthropometry, walking distance, physical activity and nutritional status did not change. There was an increase in sarcopenic status from diagnosis (pre-sarcopenic n = 2) to post-treatment (pre-sarcopenic n = 5, severely sarcopenic n = 1). Despite maintenance of body weight, functional capacity and activity habits, participants experience declines in muscle mass and strength. Interventions involving exercise and/or nutritional support to build muscle mass and strength during preoperative therapy, even in patients who are functioning normally, are warranted.

  13. Boron Neutron Capture Therapy for HER2+ breast cancers: A feasibility study evaluating BNCT for potential role in breast conservation therapies

    NASA Astrophysics Data System (ADS)

    Jenkins, Peter Anthony

    A novel Boron Neutron Capture Therapy (BNCT) regimen for the treatment of HER2+ breast cancers has been proposed as an alternative to whole breast irradiation for breast conservation therapy patients. The proposed therapy regimen is based on the assumed production of boron delivery agents that would be synthesized from compounds of Trastuzumab (Herceptin ®) and oligomeric phosphate diesters (OPDs). The combination of the anti-HER2 monoclonal antibody and the high boron loading capability of OPDs has led to the assumption that boron could be delivered to the HER2+ cancer cells at Tumor to Healthy Tissue ratios (T:H) of up to 35:1 and boron concentrations above 50 μg/g. This significantly increased boron delivery efficiency has opened new BNCT possibilities. This proof of concept study examined treatment parameters derived as the results in previous efforts in the context of patient-specific geometry and compared calculated dose results to those observed during actual patient therapy. These results were based on dose calculations performed with a set of calculated Kerma coefficients derived from tissues specific to the regions of interest for breast cancer. A comparison was made of the dose to the tumor region, the patient's skin, and the peripheral organs. The results of this study demonstrated that, given the performance of the proposed boron delivery agent, the BNCT treatment regimen is feasible. The feasibility is based on the findings that the equivalent dose could be delivered to the treatment volume with less dose to the skin and peripheral organs. This is anticipated to improve the treatment outcomes by maintaining local control of tumor cells while reducing dose to healthy tissues.

  14. L-Boronophenylalanine-Mediated Boron Neutron Capture Therapy for Malignant Glioma Progressing After External Beam Radiation Therapy: A Phase I Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kankaanranta, Leena; Seppaelae, Tiina; Koivunoro, Hanna

    Purpose: To investigate the safety of boronophenylalanine-mediated boron neutron capture therapy (BNCT) in the treatment of malignant gliomas that progress after surgery and conventional external beam radiation therapy. Methods and Materials: Adult patients who had histologically confirmed malignant glioma that had progressed after surgery and external beam radiotherapy were eligible for this Phase I study, provided that >6 months had elapsed from the last date of radiation therapy. The first 10 patients received a fixed dose, 290 mg/kg, of L-boronophenylalanine-fructose (L-BPA-F) as a 2-hour infusion before neutron irradiation, and the remaining patients were treated with escalating doses of L-BPA-F, eithermore » 350 mg/kg, 400 mg/kg, or 450 mg/kg, using 3 patients on each dose level. Adverse effects were assessed using National Cancer Institute Common Toxicity Criteria version 2.0. Results: Twenty-two patients entered the study. Twenty subjects had glioblastoma, and 2 patients had anaplastic astrocytoma, and the median cumulative dose of prior external beam radiotherapy was 59.4 Gy. The maximally tolerated L-BPA-F dose was reached at the 450 mg/kg level, where 4 of 6 patients treated had a grade 3 adverse event. Patients who were given >290 mg/kg of L-BPA-F received a higher estimated average planning target volume dose than those who received 290 mg/kg (median, 36 vs. 31 Gy [W, i.e., a weighted dose]; p = 0.018). The median survival time following BNCT was 7 months. Conclusions: BNCT administered with an L-BPA-F dose of up to 400 mg/kg as a 2-hour infusion is feasible in the treatment of malignant gliomas that recur after conventional radiation therapy.« less

  15. Tetrakis(p-carboranylthio-tetrafluorophenyl)chlorin (TPFC): application for photodynamic therapy and boron neutron capture therapy.

    PubMed

    Hiramatsu, Ryo; Kawabata, Shinji; Tanaka, Hiroki; Sakurai, Yoshinori; Suzuki, Minoru; Ono, Koji; Miyatake, Shin-ichi; Kuroiwa, Toshihiko; Hao, Erhong; Vicente, M Graça H

    2015-03-01

    Carboranyl-containing chlorins have emerged as promising dual sensitizers for use in both photodynamic therapy (PDT) and boron neutron capture therapy (BNCT), by virtue of their known tumor affinity, low cytotoxicity in dark conditions, and their strong absorptions in the red region of the optical spectrum. Tetrakis(p-carboranylthio-tetrafluorophenyl)chlorin (TPFC) is a new synthetic carboranyl-containing chlorin of high boron content (24% by weight). To evaluate TPFC's applicability as sensitizer for both PDT and BNCT, we performed an in vitro and in vivo study using F98 rat glioma cells and F98 rat glioma-bearing brain tumor models. For the in vivo BNCT study, we used boronophenylalanine (BPA), which is currently used in clinical BNCT studies, via intravenous administration (i.v.) and/or used TPFC via convection-enhanced delivery (CED), a method for local drug infusion directly into the brain. In the in vitro PDT study, the cell surviving fraction following laser irradiation (9 J/cm(2) ) was 0.035 whereas in the in vitro BNCT study, the cell surviving fraction following neutron irradiation (thermal neutron = 1.73 × 10(12) n/cm(2) ) was 0.04. In the in vivo BNCT study, the median survival time following concomitant administration of BPA (i.v.) and TPFC (CED) was 42 days (95% confidence interval; 37-43 days). © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  16. Tetrakis(p-Carboranylthio-Tetrafluorophenyl)Chlorin (TPFC): Application for Photodynamic Therapy and Boron Neutron Capture Therapy

    PubMed Central

    HIRAMATSU, RYO; KAWABATA, SHINJI; TANAKA, HIROKI; SAKURAI, YOSHINORI; SUZUKI, MINORU; ONO, KOJI; MIYATAKE, SHIN-ICHI; KUROIWA, TOSHIHIKO; HAO, ERHONG; VICENTE, M. GRAÇA H.

    2015-01-01

    Carboranyl-containing chlorins have emerged as promising dual sensitizers for use in both photodynamic therapy (PDT) and boron neutron capture therapy (BNCT), by virtue of their known tumor affinity, low cytotoxicity in dark conditions, and their strong absorptions in the red region of the optical spectrum. Tetrakis(p-carboranylthio-tetrafluorophenyl)chlorin (TPFC) is a new synthetic carboranyl-containing chlorin of high boron content (24% by weight). To evaluate TPFC’s applicability as sensitizer for both PDT and BNCT, we performed an in vitro and in vivo study using F98 rat glioma cells and F98 rat glioma-bearing brain tumor models. For the in vivo BNCT study, we used boronophenylalanine (BPA), which is currently used in clinical BNCT studies, via intravenous administration (i.v.) and/or used TPFC via convection-enhanced delivery (CED), a method for local drug infusion directly into the brain. In the in vitro PDT study, the cell surviving fraction following laser irradiation (9 J/cm2) was 0.035 whereas in the in vitro BNCT study, the cell surviving fraction following neutron irradiation (thermal neutron = 1.73 × 1012 n/cm2) was 0.04. In the in vivo BNCT study, the median survival time following concomitant administration of BPA (i.v.) and TPFC (CED) was 42 days (95% confidence interval; 37–43 days). PMID:25546823

  17. Multiple-predators-based capture process on complex networks

    NASA Astrophysics Data System (ADS)

    Ramiz Sharafat, Rajput; Pu, Cunlai; Li, Jie; Chen, Rongbin; Xu, Zhongqi

    2017-03-01

    The predator/prey (capture) problem is a prototype of many network-related applications. We study the capture process on complex networks by considering multiple predators from multiple sources. In our model, some lions start from multiple sources simultaneously to capture the lamb by biased random walks, which are controlled with a free parameter $\\alpha$. We derive the distribution of the lamb's lifetime and the expected lifetime $\\left\\langle T\\right\\rangle $. Through simulation, we find that the expected lifetime drops substantially with the increasing number of lions. We also study how the underlying topological structure affects the capture process, and obtain that locating on small-degree nodes is better than large-degree nodes to prolong the lifetime of the lamb. Moreover, dense or homogeneous network structures are against the survival of the lamb.

  18. Development of real-time thermal neutron monitor using boron-loaded plastic scintillator with optical fiber for boron neutron capture therapy.

    PubMed

    Ishikawa, M; Ono, K; Sakurai, Y; Unesaki, H; Uritani, A; Bengua, G; Kobayashi, T; Tanaka, K; Kosako, T

    2004-11-01

    A new thermal neutron monitor for boron neutron capture therapy was developed in this study. We called this monitor equipped boron-loaded plastic scintillator that uses optical fiber for signal transmission as an [scintillator with optical fiber] SOF detector. A water phantom experiment was performed to verify how the SOF detector compared with conventional method of measuring thermal neutron fluence. Measurements with a single SOF detector yielded indistinguishable signals for thermal neutrons and gamma rays. To account for the gamma ray contribution in the signal recorded by the SOF detector, a paired SOF detector system was employed. This was composed of an SOF detector with boron-loaded scintillator and an SOF detector with a boron-free scintillator. The difference between the recorded counts of these paired SOF detectors was used as the measure of the gamma ray contribution in the measured neutron fluence. The paired SOF detectors were ascertained to be effective in measuring thermal neutron flux in the range above 10(6)(n/cm(2)/s). Clinical trials using paired SOF to measure thermal neutron flux during therapy confirmed that paired SOF detectors were effective as a real-time thermal neutron flux monitor.

  19. Is gardening a stimulating activity for people with advanced Huntington's disease?

    PubMed

    Spring, Josephine A; Viera, Marc; Bowen, Ceri; Marsh, Nicola

    2014-11-01

    This study evaluated adapted gardening as an activity for people with advanced Huntington's disease (HD) and explored its therapeutic aspects. Visitors and staff completed a questionnaire and participated in structured interviews to capture further information, whereas a pictorial questionnaire was designed for residents with communication difficulties. Staff reported that gardening was a constructive, outdoor activity that promoted social interaction, physical activity including functional movement and posed cognitive challenges. Half the staff thought the activity was problem free and a third used the garden for therapy. Visitors used the garden to meet with residents socially. Despite their disabilities, HD clients enjoyed growing flourishing flowers and vegetables, labelling plants, being outside in the sun and the quiet of the garden. The garden is valued by all three groups. The study demonstrates the adapted method of gardening is a stimulating and enjoyable activity for people with advanced HD. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  20. [Development of Researches on Cytokine Mechanisms in Analgesia and Anti-inflammation in Acupuncture Therapy for Rheumatoid Arthritis].

    PubMed

    Hong, Shou-Hai; Ding, Sha-Sha; Zhang, Kuo; Xu, Yuan; Zhao, Xue; Xuan, Li-Hua; Guo, Yi

    2016-10-25

    Cytokines are closely related to the occurrence and development of rheumatoid arthritis(RA). Acupuncture exerts anti-inflammatory and analgesic effects via elevating anti-inflammatory cytokine level and reducing pro-inflammatory cytokine level and regulating Th 1/Th 2 balance, which reflects the dual directional regulatory effect of acupuncture. However, problems exist in the current researches, such as inadequate depth, limited breadth and not so up-to-date research focus. The mediocre research level and the phenomena of some contradictory results among studies also need being concerned. Therefore, progress may be attained if a holistic, dynamic and networked study is conducted on the influence of acupuncture on cytokines by combining the latest progress in the mechanisms of network of cytokines and neuroendocrine immune network, and high throughput cytokine capture assay. In this way, the mechanism of cytokines in multi-targets (such as local joints, peripheral blood circulation, central nervous system) involving the effects of acupuncture in improving RA will be known more.

  1. Microchip-Based Single-Cell Functional Proteomics for Biomedical Applications

    PubMed Central

    Lu, Yao; Yang, Liu; Wei, Wei; Shi, Qihui

    2017-01-01

    Cellular heterogeneity has been widely recognized but only recently have single cell tools become available that allow characterizing heterogeneity at the genomic and proteomic levels. We review the technological advances in microchip-based toolkits for single-cell functional proteomics. Each of these tools has distinct advantages and limitations, and a few have advanced toward being applied to address biological or clinical problems that fail to be addressed by traditional population-based methods. High-throughput single-cell proteomic assays generate high-dimensional data sets that contain new information and thus require developing new analytical framework to extract new biology. In this review article, we highlight a few biological and clinical applications in which the microchip-based single-cell proteomic tools provide unique advantages. The examples include resolving functional heterogeneity and dynamics of immune cells, dissecting cell-cell interaction by creating well-contolled on-chip microenvironment, capturing high-resolution snapshots of immune system functions in patients for better immunotherapy and elucidating phosphoprotein signaling networks in cancer cells for guiding effective molecularly targeted therapies. PMID:28280819

  2. Pacemaker leads: performance and progress.

    PubMed

    de Voogt, W G

    1999-03-11

    Pacing leads remain the "weaker link" of the permanent pacing system. Lead failure has been an issue since the beginning of implantable pacemaker therapy. Modern electronics have brought about considerable progress in pacing technology, but lead design has been slower to evolve and problems persist. IS-1 standardization must be considered a significant advance, but some issues regarding IS-1 standardization persist and have been the cause of some compatibility problems. With respect to lead insulation, silicone has proved to offer total reliability for > 30 years. In the search for better handling characteristics, polyurethane 80A was employed for bipolar leads, but it failed to demonstrate satisfactory insulating properties. New insulation materials, such as ethylene-fluoro-ethylene (ETFE), and coated wire technology look promising, having shown 99.32% survival at 5-year follow-up. Reliability is the main objective in lead design, but leads should provide low battery consumption as well. Low coil resistance, with high electrode impedance in steroid-eluting leads, is the standard at present. Low polarization is a desirable property for 2 main reasons: (1) in conjunction with low-threshold leads, it decreases battery consumption; and (2) it allows capture detection and, therefore, safer pacing at low battery consumption. Lead tip design as well as pacing pulse configuration can influence polarization.

  3. Can Students Identify the Relevant Information to Solve a Problem?

    ERIC Educational Resources Information Center

    Zhang, Lishan; Yu, Shengquan; Li, Baoping; Wang, Jing

    2017-01-01

    Solving non-routine problems is one of the most important skills for the 21st century. Traditional paper-pencil tests cannot assess this type of skill well because of their lack of interactivity and inability to capture procedural data. Tools such as MicroDYN and MicroFIN have proved to be trustworthy in assessing complex problem-solving…

  4. Problem-Based Learning in Professional Entry-Level Therapy Education: A Review of Controlled Evaluation Studies

    ERIC Educational Resources Information Center

    O'Donoghue, Grainne; McMahon, Sinead; Doody, Catherine; Smith, Kathyrn; Cusack, Tara

    2011-01-01

    Although there has been growing interest in problem-based learning (PBL) by professional entry-level therapy educators, its effectiveness is as yet unclear. Existing overviews of the field do not provide high-quality evidence in terms of the effectiveness or otherwise of PBL in professional therapy education. The purposes of this article is to…

  5. Software support environment design knowledge capture

    NASA Technical Reports Server (NTRS)

    Dollman, Tom

    1990-01-01

    The objective of this task is to assess the potential for using the software support environment (SSE) workstations and associated software for design knowledge capture (DKC) tasks. This assessment will include the identification of required capabilities for DKC and hardware/software modifications needed to support DKC. Several approaches to achieving this objective are discussed and interim results are provided: (1) research into the problem of knowledge engineering in a traditional computer-aided software engineering (CASE) environment, like the SSE; (2) research into the problem of applying SSE CASE tools to develop knowledge based systems; and (3) direct utilization of SSE workstations to support a DKC activity.

  6. Broad-search algorithms for the spacecraft trajectory design of Callisto-Ganymede-Io triple flyby sequences from 2024 to 2040, Part II: Lambert pathfinding and trajectory solutions

    NASA Astrophysics Data System (ADS)

    Lynam, Alfred E.

    2014-01-01

    Triple-satellite-aided capture employs gravity-assist flybys of three of the Galilean moons of Jupiter in order to decrease the amount of ΔV required to capture a spacecraft into Jupiter orbit. Similarly, triple flybys can be used within a Jupiter satellite tour to rapidly modify the orbital parameters of a Jovicentric orbit, or to increase the number of science flybys. In order to provide a nearly comprehensive search of the solution space of Callisto-Ganymede-Io triple flybys from 2024 to 2040, a third-order, Chebyshev's method variant of the p-iteration solution to Lambert's problem is paired with a second-order, Newton-Raphson method, time of flight iteration solution to the V∞-matching problem. The iterative solutions of these problems provide the orbital parameters of the Callisto-Ganymede transfer, the Ganymede flyby, and the Ganymede-Io transfer, but the characteristics of the Callisto and Io flybys are unconstrained, so they are permitted to vary in order to produce an even larger number of trajectory solutions. The vast amount of solution data is searched to find the best triple-satellite-aided capture window between 2024 and 2040.

  7. Source Update Capture in Information Agents

    NASA Technical Reports Server (NTRS)

    Ashish, Naveen; Kulkarni, Deepak; Wang, Yao

    2003-01-01

    In this paper we present strategies for successfully capturing updates at Web sources. Web-based information agents provide integrated access to autonomous Web sources that can get updated. For many information agent applications we are interested in knowing when a Web source to which the application provides access, has been updated. We may also be interested in capturing all the updates at a Web source over a period of time i.e., detecting the updates and, for each update retrieving and storing the new version of data. Previous work on update and change detection by polling does not adequately address this problem. We present strategies for intelligently polling a Web source for efficiently capturing changes at the source.

  8. A Randomized Trial of Brief Interventions for Problem and Pathological Gamblers

    ERIC Educational Resources Information Center

    Petry, Nancy M.; Weinstock, Jeremiah; Ledgerwood, David M.; Morasco, Benjamin

    2008-01-01

    Limited research exists regarding methods for reducing problem gambling. Problem gamblers (N = 180) were randomly assigned to assessment only control, 10 min of brief advice, 1 session of motivational enhancement therapy (MET), or 1 session of MET plus 3 sessions of cognitive-behavioral therapy. Gambling was assessed at baseline, at 6 weeks, and…

  9. Automated generation and optimization of ballistic lunar capture transfer trajectories

    NASA Astrophysics Data System (ADS)

    Griesemer, Paul Ricord

    The successful completion of the Hiten mission in 1991 provided real-world validation of a class of trajectories defined as ballistic lunar capture transfers. This class of transfers is often considered for missions to the Moon and for tours of the moons of other planets. In this study, the dynamics of the three and four body problems are examined to better explain the mechanisms of low energy transfers in the Earth-Moon system, and to determine their optimality. Families of periodic orbits in the restricted Earth-Sun-spacecraft three body problem are shown to be generating families for low energy transfers between orbits of the Earth. The low energy orbit-to-orbit transfers are shown to require less fuel than optimal direct transfers between the same orbits in the Earth-Sun-spacecraft circular restricted three body problem. The low energy transfers are categorized based on their generating family and the number of flybys in the reference three body trajectory. The practical application of these generating families to spacecraft mission design is demonstrated through a robust nonlinear targeting algorithm for finding Sun-Earth-Moon-spacecraft four body transfers based on startup transfers indentified in the Earth-Sun three body problem. The local optimality of the transfers is examined through use of Lawden's primer vector theory, and new conditions of optimality for single-impulse-to-capture lunar transfers are established.

  10. Experiences and Perceptions of Problem Gamblers on Cognitive and Exposure Therapies When Taking Part in a Randomised Controlled Trial: A Qualitative Study.

    PubMed

    Smith, David; Pols, Rene; Lavis, Tiffany; Battersby, Malcolm; Harvey, Peter

    2016-12-01

    In South Australia (SA) problem gambling is mainly a result of the widespread availability of electronic gaming machines. A key treatment provider in SA offers free cognitive and behavioural therapy (CBT) to help-seeking problem gamblers. The CBT program focuses on the treatment of clients' urge to gamble using exposure therapy (ET) and cognitive therapy (CT) to restructure erroneous gambling beliefs. The aim of this study was to explore treatment specific and non-specific effects for CT alone and ET alone using qualitative interviews. Interviewees were a sub-sample of participants from a randomised trial that investigated the relative efficacy of CT versus ET. Findings revealed that all interviewees gained benefit from their respective therapies and their comments did not appear to favour one therapy over another. Both treatment specific and treatment non-specific effects were well supported as playing a therapeutic role to recovery. Participants' comments in both therapy groups suggested that symptom reduction was experienced on a gambling related urge-cognition continuum. In addition to symptom improvement from therapy-specific mechanisms, ET participants described a general acquisition of "rational thought" from their program of therapy and CT participants had "taken-over" their gambling urges. The findings also highlighted areas for further improvement including therapy drop-out.

  11. [Theraplay--interactive therapy between parent and child in juvenile mental problems].

    PubMed

    Mäkelä, Jukka; Salo, Saara

    2011-01-01

    Parent-child interaction therapy is an effective means to prevent and correct children's mental problems. Interactive interventions shown to be effective share common features: the focus is on the support of the parent's sensitivity, positive guiding ability and reflective capability. Simultaneous participation of both parents in the therapy, application of video observation and affirmation of positive collaborative relationship with the parents seem to increase the efficacy of the intervention. The above-mentioned elements are utilized in an interactive therapy method called Theraplay.

  12. Accelerator driven neutron source design via beryllium target and 208Pb moderator for boron neutron capture therapy in alternative treatment strategy by Monte Carlo method.

    PubMed

    Khorshidi, Abdollah

    2017-01-01

    The reactor has increased its area of application into medicine especially boron neutron capture therapy (BNCT); however, accelerator-driven neutron sources can be used for therapy purposes. The present study aimed to discuss an alternative method in BNCT functions by a small cyclotron with low current protons based on Karaj cyclotron in Iran. An epithermal neutron spectrum generator was simulated with 30 MeV proton energy for BNCT purposes. A low current of 300 μA of the proton beam in spallation target concept via 9Be target was accomplished to model neutron spectrum using 208Pb moderator around the target. The graphite reflector and dual layer collimator were planned to prevent and collimate the neutrons produced from proton interactions. Neutron yield per proton, energy distribution, flux, and dose components in the simulated head phantom were estimated by MCNPX code. The neutron beam quality was investigated by diverse filters thicknesses. The maximum epithermal flux transpired using Fluental, Fe, Li, and Bi filters with thicknesses of 7.4, 3, 0.5, and 4 cm, respectively; as well as the epithermal to thermal neutron flux ratio was 161. Results demonstrated that the induced neutrons from a low energy and low current proton may be effective in tumor therapy using 208Pb moderator with average lethargy and also graphite reflector with low absorption cross section to keep the generated neutrons. Combination of spallation-based BNCT and proton therapy can be especially effective, if a high beam intensity cyclotron becomes available.

  13. Drug therapy problems and medication discrepancies during care transitions in super-utilizers.

    PubMed

    Surbhi, Satya; Munshi, Kiraat D; Bell, Paula C; Bailey, James E

    First, to investigate the prevalence and types of drug therapy problems and medication discrepancies among super-utilizers, and associated patient characteristics. Second, to examine the outcomes of pharmacist recommendations and estimated cost avoidance through care transitions support focused on medication management. Retrospective analysis of the pharmacist-led interventions as part of the SafeMed Program. A large nonprofit health care system serving the major medically underserved areas in Memphis, Tennessee. Three hundred seventy-four super-utilizing SafeMed participants with multiple chronic conditions and polypharmacy. Comprehensive medication review, medication therapy management, enhanced discharge planning, home visits, telephone follow-up, postdischarge medication reconciliation, and care coordination with physicians. Types of drug therapy problems, outcomes of pharmacist recommendations, estimated cost avoided, medication discrepancies, and self-reported medication adherence. Prevalence of drug therapy problems and postdischarge medication discrepancies was 80.7% and 75.4%, respectively. The most frequently occurring drug therapy problems were enrollee not receiving needed medications (33.4%), underuse of medications (16.9%), and insufficient dose or duration (11.2%). Overall 50.8% of the pharmacist recommendations were accepted by physicians and patients, resulting in an estimated cost avoidance of $293.30 per drug therapy problem identified. Multivariate analysis indicated that participants with a higher number of comorbidities were more likely to have medication discrepancies (odds ratio 1.23 [95% CI 1.05-1.44]). Additional contributors to postdischarge medication discrepancies were difficulty picking up and paying for medications and not being given necessary prescriptions before discharge. Drug therapy problems and medication discrepancies are common in super-utilizers with multiple chronic conditions and polypharmacy during transitions of care, and greater levels of comorbidity magnify risk. Pharmacist-led interventions in the SafeMed Program have demonstrated success in resolving enrollees' medication-related issues, resulting in substantial estimated cost savings. Preliminary evidence suggests that the SafeMed model's focus on medication management has great potential to improve outcomes while reducing costs for vulnerable super-utilizing populations nationwide. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  14. Obstacle Crossing During Gait in Children With Cerebral Palsy: Cross-Sectional Study With Kinematic Analysis of Dynamic Balance and Trunk Control.

    PubMed

    Malone, Ailish; Kiernan, Damien; French, Helen; Saunders, Valerie; O'Brien, Timothy

    2016-08-01

    Balance problems are common in children who have cerebral palsy (CP) but are active and ambulant. Control of the whole-body center of mass is critical in maintaining dynamic stability during challenging mobility tasks, such as clearing an obstacle while walking. The objective of this study was to compare trunk and lower limb kinematics and center-of-mass control in children with CP and those in children with typical development during obstacle crossing. This was a cross-sectional study. Thirty-four children who were 5 to 17 years of age (17 with CP and 17 with typical development) and matched in age and height completed 2 gait trials involving crossing a 10-cm obstacle. Three-dimensional kinematic and kinetic data were captured with a general-purpose 3-dimensional motion tracking system and forceplates. Trunk data were captured with a validated model. All children cleared the obstacle with similar hip and knee kinematics, step length, and single-support duration. In children with CP, step width was increased by 4.81 cm, and center-of-mass velocity was significantly slower at lead limb toe-off (0.31 m/s) and during lead limb clearance (0.2 m/s). Children with CP showed altered trunk and pelvis movement, characterized by significantly greater pelvic obliquity, pelvic tilt, and trunk rotation throughout the task, increased lateral trunk lean during lead limb crossing (3.7°), and greater sagittal trunk movement as the trail limb crossed (5.1°). The study was not powered to analyze differences between children with diplegia and those with hemiplegia. Children with CP required greater adjustments at the trunk and pelvis to achieve successful obstacle crossing. The increase in trunk movement could have been compensatory for reduced stability distally or for a primary problem reflecting poor proximal control. The findings suggest that rehabilitation should focus on both proximal trunk control and distal stability to improve balance. © 2016 American Physical Therapy Association.

  15. Music therapy with bereaved teenagers: a mixed methods perspective.

    PubMed

    McFerran, Katrina; Roberts, Melina; O'Grady, Lucy

    2010-07-01

    Qualitative investigations have indicated that music therapy groups may be beneficial for bereaved teenagers. The existing relationship between young people and music serves as a platform for connectedness and emotional expression that is utilised within a therapeutic, support group format. This investigation confirms this suggestion through grounded theory analysis of focus group interviews. Changes in self-perception were not found as a result of participation, however practically significant results were found on adolescent coping. These cannot be generalized because of the small sample size. Grief specific tools are recommended for use in future investigations in order to capture the emotional impact of music therapy grief work with adolescents.

  16. A new proportion measure of the treatment effect captured by candidate surrogate endpoints.

    PubMed

    Kobayashi, Fumiaki; Kuroki, Manabu

    2014-08-30

    The use of surrogate endpoints is expected to play an important role in the development of new drugs, as they can be used to reduce the sample size and/or duration of randomized clinical trials. Biostatistical researchers and practitioners have proposed various surrogacy measures; however, (i) most of these surrogacy measures often fall outside the range [0,1] without any assumptions, (ii) these surrogacy measures do not provide a cut-off value for judging a surrogacy level of candidate surrogate endpoints, and (iii) most surrogacy measures are highly variable; thus, the confidence intervals are often unacceptably wide. In order to solve problems (i) and (ii), we propose a new surrogacy measure, a proportion of the treatment effect captured by candidate surrogate endpoints (PCS), on the basis of the decomposition of the treatment effect into parts captured and non-captured by the candidate surrogate endpoints. In order to solve problem (iii), we propose an estimation method based on the half-range mode method with the bootstrap distribution of the estimated surrogacy measures. Finally, through numerical experiments and two empirical examples, we show that the PCS with the proposed estimation method overcomes these difficulties. The results of this paper contribute to the reliable evaluation of how much of the treatment effect is captured by candidate surrogate endpoints. Copyright © 2014 John Wiley & Sons, Ltd.

  17. Validation of an enzyme-linked immunosorbent assay that detects Histoplasma capsulatum antigenuria in Colombian patients with AIDS for diagnosis and follow-up during therapy.

    PubMed

    Caceres, Diego H; Scheel, Christina M; Tobón, Angela M; Ahlquist Cleveland, Angela; Restrepo, Angela; Brandt, Mary E; Chiller, Tom; Gómez, Beatriz L

    2014-09-01

    We validated an antigen capture enzyme-linked immunosorbent assay (ELISA) in Colombian persons with AIDS and proven histoplasmosis and evaluated the correlation between antigenuria and clinical improvement during follow-up. The sensitivity of the Histoplasma capsulatum ELISA was 86%, and the overall specificity was 94%. The antigen test successfully monitored the response to therapy. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  18. Sex Therapy

    MedlinePlus

    Sex therapy Overview Sex therapy is a type of psychotherapy — a general term for treating mental health problems by talking with a mental health professional. Through sex therapy, you can address concerns about sexual function, ...

  19. Graft Immunocomplex Capture Fluorescence Analysis to Detect Donor-Specific Antibodies and HLA Antigen Complexes in the Allograft.

    PubMed

    Nakamura, Tsukasa; Ushigome, Hidetaka; Watabe, Kiyoko; Imanishi, Yui; Masuda, Koji; Matsuyama, Takehisa; Harada, Shumpei; Koshino, Katsuhiro; Iida, Taku; Nobori, Shuji; Yoshimura, Norio

    2017-04-01

    Immunocomplex capture fluorescence analysis (ICFA) is an attractive method to detect donor-specific anti-HLA antibodies (DSA) and HLA antigen complexes. Currently, antibody-mediated rejection (AMR) due to DSA is usually diagnosed by C4d deposition and serological DSA detection. Conversely, there is a discrepancy between these findings frequently. Thereupon, our graft ICFA technique may contribute to establish the diagnosis of AMR. Graft samples were obtained by a percutaneous needle biopsy. Then, the specimen was dissolved in PBS by the lysis buffer. Subsequently, HLA antigens were captured by anti-HLA beads. Then, DSA-HLA complexes were detected by PE-conjugated anti-human IgG antibodies, where DSA had already reacted with the allograft in vivo, analyzed by a Luminex system. A ratio (sample MFI/blank beads MFI) was calculated: ≥ 1.0 was determined as positive. We found that DSA-HLA complexes in the graft were successfully detected from only slight positive 1.03 to 79.27 in a chronic active AMR patient by graft ICFA. Next, positive graft ICFA had predicted the early phase of AMR (MFI ratio: 1.38) even in patients with no serum DSA. Finally, appropriate therapies for AMR deleted DSA deposition (MFI ratio from 0.3 to 0.7) from allografts. This novel application would detect early phase or incomplete pathological cases of AMR, which could lead to a correct diagnosis and initiation of appropriate therapies. Moreover, graft ICFA might address a variety of long-standing questions in terms of DSA. AMR: Antibody-mediated rejection; DSA: Donor-specific antibodies; ICFA: Immunocomplex capture fluorescence analysis.

  20. The Strategic Systems Therapies: Measuring the Models.

    ERIC Educational Resources Information Center

    Rohrbaugh, Michael

    As family therapy becomes a serious intellectual disipline, the relationships among its leading variations require closer examination. To examine similarities and differences among four closely related approaches (brief, problem-focused therapy; structural family therapy; strategic family therapy; and systemic family therapy) and to determine if…

  1. Developments in capture-γ libraries for nonproliferation applications

    NASA Astrophysics Data System (ADS)

    Hurst, A. M.; Firestone, R. B.; Sleaford, B. W.; Bleuel, D. L.; Basunia, M. S.; Bečvář, F.; Belgya, T.; Bernstein, L. A.; Carroll, J. J.; Detwiler, B.; Escher, J. E.; Genreith, C.; Goldblum, B. L.; Krtička, M.; Lerch, A. G.; Matters, D. A.; McClory, J. W.; McHale, S. R.; Révay, Zs.; Szentmiklosi, L.; Turkoglu, D.; Ureche, A.; Vujic, J.

    2017-09-01

    The neutron-capture reaction is fundamental for identifying and analyzing the γ-ray spectrum from an unknown assembly because it provides unambiguous information on the neutron-absorbing isotopes. Nondestructive-assay applications may exploit this phenomenon passively, for example, in the presence of spontaneous-fission neutrons, or actively where an external neutron source is used as a probe. There are known gaps in the Evaluated Nuclear Data File libraries corresponding to neutron-capture γ-ray data that otherwise limit transport-modeling applications. In this work, we describe how new thermal neutron-capture data are being used to improve information in the neutron-data libraries for isotopes relevant to nonproliferation applications. We address this problem by providing new experimentally-deduced partial and total neutron-capture reaction cross sections and then evaluate these data by comparison with statistical-model calculations.

  2. Reduced stress and improved physical functional ability in elderly with mental health problems following a horticultural therapy program.

    PubMed

    Han, Ah-Reum; Park, Sin-Ae; Ahn, Byung-Eun

    2018-06-01

    This study aimed to determine the effects of a plant cultivation-based horticultural therapy program for elderly people with mental health problems. Pre- and post-test design with experimental and control groups. Twenty-eight elderly Korean people with mental health problems participated from April to June 2017 at a farm located in Suwon, South Korea. The participants were randomly assigned to either the control (n = 14) or horticultural therapy group (n = 14); the latter participated in once-weekly sessions of a previously designed 10-session horticultural therapy program. The pre-test occurred 1 week before starting the horticultural therapy program. The post-test was completed within 1 week after finishing the final program session. Cortisol levels were measured in saliva samples collected from both groups. The Senior Fitness Test was used to assess physical functional ability in both groups. In the horticultural therapy group, the cortisol levels decreased significantly from before to after the horticultural therapy program, and the post-test scores for six subtests of the Senior Fitness Test improved significantly. No significant improvements were seen in either measure in the control group. This study demonstrates the potential ability of horticultural therapy to improve the stress levels and physical functional abilities of elderly people with mental health problems. In future studies, it would be interesting to verify the long-term effects of this horticultural therapy program and to compare its effects with regard to sex, age, and various mental symptoms. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Optimal Low Energy Earth-Moon Transfers

    NASA Technical Reports Server (NTRS)

    Griesemer, Paul Ricord; Ocampo, Cesar; Cooley, D. S.

    2010-01-01

    The optimality of a low-energy Earth-Moon transfer is examined for the first time using primer vector theory. An optimal control problem is formed with the following free variables: the location, time, and magnitude of the transfer insertion burn, and the transfer time. A constraint is placed on the initial state of the spacecraft to bind it to a given initial orbit around a first body, and on the final state of the spacecraft to limit its Keplerian energy with respect to a second body. Optimal transfers in the system are shown to meet certain conditions placed on the primer vector and its time derivative. A two point boundary value problem containing these necessary conditions is created for use in targeting optimal transfers. The two point boundary value problem is then applied to the ballistic lunar capture problem, and an optimal trajectory is shown. Additionally, the ballistic lunar capture trajectory is examined to determine whether one or more additional impulses may improve on the cost of the transfer.

  4. Evolution of neurocognitive function in long-term survivors of childhood acute lymphoblastic leukemia treated with chemotherapy only.

    PubMed

    Liu, Wei; Cheung, Yin Ting; Conklin, Heather M; Jacola, Lisa M; Srivastava, DeoKumar; Nolan, Vikki G; Zhang, Hongmei; Gurney, James G; Huang, I-Chan; Robison, Leslie L; Pui, Ching-Hon; Hudson, Melissa M; Krull, Kevin R

    2018-06-01

    The purpose of this study was to determine the evolution of neurocognitive problems from therapy completion to long-term follow-up in survivors of childhood acute lymphoblastic leukemia treated with chemotherapy only. We evaluated whether attention problems observed at therapy completion evolve into long-term executive dysfunction in 158 survivors treated on a single institution protocol. Treatment data (high-dose intravenous methotrexate exposure [serum concentration] and triple intrathecal chemotherapy injections) were collected. Parent report of behavior and direct cognitive testing of survivors was conducted at end of therapy, and survivors completed neurocognitive testing when > 5 years post-diagnosis. At the end of chemotherapy, survivors (52% female; mean age 9.2 years) demonstrated higher frequency of impairment in sustained attention (38%) and parent-reported inattention (20%) compared to population expectations (10%). At long-term follow-up, survivors (mean age 13.7 years; 7.6 years post-diagnosis) demonstrated higher impairment in executive function (flexibility 24%, fluency 21%), sustained attention (15%), and processing speed (15%). Sustained attention improved from end of therapy to long-term follow-up (p < 0.001). Higher methotrexate AUC and greater number of intrathecal injections were associated with attention problems (p = 0.009, p = 0.002, respectively) at the end of chemotherapy and executive function (p < 0.001, p = 0.02, respectively) problems at long-term follow-up. Attention problems at the end of therapy were not associated with executive function problems at long-term follow-up (p's > 0.05). The direct effect of chemotherapy exposure predicted outcomes at both time points. Survivors should be monitored for neurocognitive problems well into long-term survivorship, regardless of whether they show attention problems at the end of therapy. Treatment exposures are the best predictor of long-term complications.

  5. Post-treatment skin reactions reported by cancer patients differ by race, not by treatment or expectations

    PubMed Central

    Ryan, J L; Bole, C; Hickok, J T; Figueroa-Moseley, C; Colman, L; Khanna, R C; Pentland, A P; Morrow, G R

    2007-01-01

    Cancer patients may experience skin problems while undergoing chemotherapy and radiation therapy. Frequency of skin reactions may be influenced by skin pigmentation and psychological factors. A Symptom Inventory completed by 656 cancer patients nationwide before and after chemotherapy, radiation therapy, or chemotherapy plus radiation therapy was analysed to determine if treatment type, race (Black vs White), and pretreatment expectations influenced post-treatment skin reactions. Subsequent analysis of a local Symptom Inventory completed weekly for 5 weeks by 308 patients receiving radiation therapy examined severity of reported skin reactions. Significantly more patients receiving radiation therapy had stronger expectations of skin problems (62%) than patients receiving chemotherapy (40%, P=0.001) or chemotherapy plus radiation therapy (45%, P=0.003). Overall, expectations did not correlate with patient reported post-treatment skin problems in white (r=0.014, P=0.781) or black (r=0.021, P=0.936) patients. Although no significant difference was found between black and white patients in their pretreatment expectations of skin problems (P=0.32), black patients (10 out of 18, 56%) reported more skin problems than white patients (90 out of 393, 23%, P=0.001). Similarly, the local study showed that significantly more black patients (1 out of 5, 20%) reported severe skin reactions at the treatment site than white patients (12 out of 161, 8%). A direct correlation was observed between severity of skin problems and pain at the treatment site (r=0.541, P<0.001). Total radiation exposure did not significantly correlate with the report of skin problems at the treatment site for white or black patients. Overall, black patients reported more severe post-treatment skin problems than white patients. Our results suggest that symptom management for post-treatment skin reactions in cancer patients receiving radiation treatment could differ depending on their racial background. PMID:17565347

  6. Predicting Behavioral Problems in Craniopharyngioma Survivors after Conformal Radiation Therapy

    PubMed Central

    Dolson, Eugenia P.; Conklin, Heather M.; Li, Chenghong; Xiong, Xiaoping; Merchant, Thomas E.

    2009-01-01

    Background Although radiation therapy is a primary treatment for craniopharyngioma, it can exacerbate existing problems related to the tumor and pre-irradiation management. Survival is often marked by neurologic deficits, panhypopituitarism, diabetes insipidus, cognitive deficiencies and behavioral and social problems. Procedure The Achenbach Child Behavior Checklist (CBCL) was used to evaluate behavioral and social problems during the first five years of follow-up in 27 patients with craniopharyngioma treated with conformal radiation therapy. Results All group averages for the CBCL scales were within the age-typical range at pre-irradiation baseline. Extent of surgical resection was implicated in baseline differences for the Internalizing, Externalizing, Behavior Problem and Social scores. Significant longitudinal changes were found in Internalizing, Externalizing, Behavior Problem and School scores that correlated with tumor and treatment related factors. Conclusions The most common variables implicated in post-irradiation behavioral and social problems were CSF shunting, presence of an Ommaya reservoir, diabetes insipidus, and low pre-irradiation growth hormone levels. PMID:19191345

  7. Randomized Trial of Treatment for Children with Sexual Behavior Problems: Ten-Year Follow-Up

    ERIC Educational Resources Information Center

    Carpentier, Melissa Y.; Silovsky, Jane F.; Chaffin, Mark

    2006-01-01

    This study prospectively follows 135 children 5-12 years of age with sexual behavior problems from a randomized trial comparing a 12-session group cognitive-behavioral therapy (CBT) with group play therapy and follows 156 general clinic children with nonsexual behavior problems. Ten-year follow-up data on future juvenile and adult arrests and…

  8. [Application of music therapy for managing agitated behavior in older people with dementia].

    PubMed

    Sung, Huei-Chuan; Chang, Anne M; Abbey, Jennifer

    2006-10-01

    Older people with dementia may display negative emotions, memory problems, sleep disturbance, and agitated behavior. Among these symptoms, agitated behavior has been identified by families and nursing staff as the care problem that presents the greatest challenge. Several studies have found that music therapy reduced agitated behaviors in those with dementia and recommended use of music as an effective strategy in managing this behavioral problem. Music therapy represents a lower cost, effective care approach that nursing staff can easily learn and apply to those with dementia. Furthermore, reductions in agitated behavior in dementia patients that result from music therapy can also alleviate caregiver stress and burden of care, leading to improvements in the health and quality of life of both dementia patients and their caregivers. This paper aims to introduce the principles and application of music therapy in the management of agitated behavior in those with dementia.

  9. What is occupational therapy’s role in addressing sleep problems among older adults?

    PubMed Central

    Leland, Natalie E.; Marcione, Nicole; Niemiec, Stacey L. Schepens; Don Fogelberg, Kaivalya Kelkar

    2014-01-01

    Sleep problems, prevalent among older adults, are associated with poor outcomes and high healthcare costs. In 2008, rest and sleep became its own area of occupation in the AOTA Occupational Therapy Practice Framework. This scoping review examined a broad context of sleep research in order to highlight efficacious interventions for older adults that fall within the occupational therapy scope of practice and present an agenda for research and practice. Four sleep intervention areas clearly aligned with the Practice Framework, including cognitive behavioral therapy for insomnia, physical activity, and multi-component interventions. Occupational therapy is primed to address sleep problems by targeting the context and environment, performance patterns, and limited engagement in evening activities that may contribute to poor sleep. Occupational therapy researchers and clinicians need to work collaboratively to establish the evidence-base for occupation-centered sleep interventions in order to improve the health and quality of life of the older adult. PMID:24844879

  10. Meaning and challenges in the practice of multiple therapeutic massage modalities: a combined methods study.

    PubMed

    Porcino, Antony J; Boon, Heather S; Page, Stacey A; Verhoef, Marja J

    2011-09-20

    Therapeutic massage and bodywork (TMB) practitioners are predominantly trained in programs that are not uniformly standardized, and in variable combinations of therapies. To date no studies have explored this variability in training and how this affects clinical practice. Combined methods, consisting of a quantitative, population-based survey and qualitative interviews with practitioners trained in multiple therapies, were used to explore the training and practice of TMB practitioners in Alberta, Canada. Of the 5242 distributed surveys, 791 were returned (15.1%). Practitioners were predominantly female (91.7%), worked in a range of environments, primarily private (44.4%) and home clinics (35.4%), and were not significantly different from other surveyed massage therapist populations. Seventy-seven distinct TMB therapies were identified. Most practitioners were trained in two or more therapies (94.4%), with a median of 8 and range of 40 therapies. Training programs varied widely in number and type of TMB components, training length, or both. Nineteen interviews were conducted. Participants described highly variable training backgrounds, resulting in practitioners learning unique combinations of therapy techniques. All practitioners reported providing individualized patient treatment based on a responsive feedback process throughout practice that they described as being critical to appropriately address the needs of patients. They also felt that research treatment protocols were different from clinical practice because researchers do not usually sufficiently acknowledge the individualized nature of TMB care provision. The training received, the number of therapies trained in, and the practice descriptors of TMB practitioners are all highly variable. In addition, clinical experience and continuing education may further alter or enhance treatment techniques. Practitioners individualize each patient's treatment through a highly adaptive process. Therefore, treatment provision is likely unique to each practitioner. These results may be of interest to researchers considering similar practice issues in other professions. The use of a combined-methods design effectively captured this complexity of TMB practice. TMB research needs to consider research approaches that can capture or adapt to the individualized nature of practice.

  11. Pharmaco-thermodynamics of deuterium-induced oedema in living rat brain via 1H2O MRI: implications for boron neutron capture therapy of malignant brain tumours

    NASA Astrophysics Data System (ADS)

    Medina, Daniel C.; Li, Xin; Springer, Charles S., Jr.

    2005-05-01

    In addition to its common usage as a tracer in metabolic and physiological studies, deuterium possesses anti-tumoural activity and confers protection against γ-irradiation. A more recent interest in deuterium emanates from the search for alternatives capable of improving neutron penetrance whilst reducing healthy tissue radiation dose deposition in boron neutron capture therapy of malignant brain tumours. Despite this potential clinical application, deuterium induces brain oedema, which is detrimental to neutron capture therapy. In this study, five adult male rats were titrated with deuterated drinking water while brain oedema was monitored via water proton magnetic resonance imaging. This report concludes that deuterium, as well as deuterium-induced brain oedema, possesses a uniform brain bio-distribution. At a steady-state blood fluid deuteration value of 16%, when the deuterium isotope fraction in drinking water was 25%, a mean oedematous volume change of 9 ± 2% (p-value <0.001) was observed in the rat brain—this may account for neurological and behavioural abnormalities found in mammals drinking highly deuterated water. In addition to characterizing the pharmaco-thermodynamics of deuterium-induced oedema, this report also estimates the impact of oedema on thermal neutron enhancement and effective dose reduction factors using simple linear transport calculations. While body fluid deuteration enhances thermal neutron flux penetrance and reduces dose deposition, oedema has the opposite effect because it increases the volume of interest, e.g., the brain volume. Thermal neutron enhancement and effective dose reduction factors could be reduced by as much as ~10% in the presence of a 9% water volume increase (oedema). All three authors have contributed equally to this work.

  12. DNA damage induced by boron neutron capture therapy is partially repaired by DNA ligase IV.

    PubMed

    Kondo, Natsuko; Sakurai, Yoshinori; Hirota, Yuki; Tanaka, Hiroki; Watanabe, Tsubasa; Nakagawa, Yosuke; Narabayashi, Masaru; Kinashi, Yuko; Miyatake, Shin-ichi; Hasegawa, Masatoshi; Suzuki, Minoru; Masunaga, Shin-ichiro; Ohnishi, Takeo; Ono, Koji

    2016-03-01

    Boron neutron capture therapy (BNCT) is a particle radiation therapy that involves the use of a thermal or epithermal neutron beam in combination with a boron ((10)B)-containing compound that specifically accumulates in tumor. (10)B captures neutrons and the resultant fission reaction produces an alpha ((4)He) particle and a recoiled lithium nucleus ((7)Li). These particles have the characteristics of high linear energy transfer (LET) radiation and therefore have marked biological effects. High-LET radiation is a potent inducer of DNA damage, specifically of DNA double-strand breaks (DSBs). The aim of the present study was to clarify the role of DNA ligase IV, a key player in the non-homologous end-joining repair pathway, in the repair of BNCT-induced DSBs. We analyzed the cellular sensitivity of the mouse embryonic fibroblast cell lines Lig4-/- p53-/- and Lig4+/+ p53-/- to irradiation using a thermal neutron beam in the presence or absence of (10)B-para-boronophenylalanine (BPA). The Lig4-/- p53-/- cell line had a higher sensitivity than the Lig4+/+ p53-/-cell line to irradiation with the beam alone or the beam in combination with BPA. In BNCT (with BPA), both cell lines exhibited a reduction of the 50 % survival dose (D 50) by a factor of 1.4 compared with gamma-ray and neutron mixed beam (without BPA). Although it was found that (10)B uptake was higher in the Lig4+/+ p53-/- than in the Lig4-/- p53-/- cell line, the latter showed higher sensitivity than the former, even when compared at an equivalent (10)B concentration. These results indicate that BNCT-induced DNA damage is partially repaired using DNA ligase IV.

  13. Scientific perspectives on music therapy.

    PubMed

    Hillecke, Thomas; Nickel, Anne; Bolay, Hans Volker

    2005-12-01

    What needs to be done on the long road to evidence-based music therapy? First of all, an adequate research strategy is required. For this purpose the general methodology for therapy research should be adopted. Additionally, music therapy needs a variety of methods of allied fields to contribute scientific findings, including mathematics, natural sciences, behavioral and social sciences, as well as the arts. Pluralism seems necessary as well as inevitable. At least two major research problems can be identified, however, that make the path stony: the problem of specificity and the problem of eclecticism. Neuroscientific research in music is giving rise to new ideas, perspectives, and methods; they seem to be promising prospects for a possible contribution to a theoretical and empirical scientific foundation for music therapy. Despite the huge heterogeneity of theoretical approaches in music therapy, an integrative model of working ingredients in music therapy is useful as a starting point for empirical studies in order to question what specifically works in music therapy. For this purpose, a heuristic model, consisting of five music therapy working factors (attention modulation, emotion modulation, cognition modulation, behavior modulation, and communication modulation) has been developed by the Center for Music Therapy Research (Viktor Dulger Institute) in Heidelberg. Evidence shows the effectiveness of music therapy for treating certain diseases, but the question of what it is in music therapy that works remains largely unanswered. The authors conclude with some questions to neuroscientists, which we hope may help elucidate relevant aspects of a possible link between the two disciplines.

  14. The use of auxiliary variables in capture-recapture and removal experiments

    USGS Publications Warehouse

    Pollock, K.H.; Hines, J.E.; Nichols, J.D.

    1984-01-01

    The dependence of animal capture probabilities on auxiliary variables is an important practical problem which has not been considered in the development of estimation procedures for capture-recapture and removal experiments. In this paper the linear logistic binary regression model is used to relate the probability of capture to continuous auxiliary variables. The auxiliary variables could be environmental quantities such as air or water temperature, or characteristics of individual animals, such as body length or weight. Maximum likelihood estimators of the population parameters are considered for a variety of models which all assume a closed population. Testing between models is also considered. The models can also be used when one auxiliary variable is a measure of the effort expended in obtaining the sample.

  15. Subcellular boron and fluorine distributions with SIMS ion microscopy in BNCT and cancer research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Subhash Chandra

    2008-05-30

    The development of a secondary ion mass spectrometry (SIMS) based technique of Ion Microscopy in boron neutron capture therapy (BNCT) was the main goal of this project, so that one can study the subcellular location of boron-10 atoms and their partitioning between the normal and cancerous tissue. This information is fundamental for the screening of boronated drugs appropriate for neutron capture therapy of cancer. Our studies at Cornell concentrated mainly on studies of glioblastoma multiforme (GBM). The early years of the grant were dedicated to the development of cryogenic methods and correlative microscopic approaches so that a reliable subcellular analysismore » of boron-10 atoms can be made with SIMS. In later years SIMS was applied to animal models and human tissues of GBM for studying the efficacy of potential boronated agents in BNCT. Under this grant the SIMS program at Cornell attained a new level of excellence and collaborative SIMS studies were published with leading BNCT researchers in the U.S.« less

  16. Nuclear magnetic resonance study of Gd-based nanoparticles to tag boron compounds in boron neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Corti, M.; Bonora, M.; Borsa, F.; Bortolussi, S.; Protti, N.; Santoro, D.; Stella, S.; Altieri, S.; Zonta, C.; Clerici, A. M.; Cansolino, L.; Ferrari, C.; Dionigi, P.; Porta, A.; Zanoni, G.; Vidari, G.

    2011-04-01

    We report the investigation of new organic complexes containing a magnetic moment (Gd-based molecular nanomagnets), which can serve the double purpose of acting as boron neutron capture therapy (BNCT) agents, and at the same time act as contrast agents to detect the molecule in the tissue by a proton magnetic resonance imaging (MRI). We also explore the possibility of monitoring the concentration of the BNCT agent directly via proton and boron NMR relaxation. The absorption of 10B-enriched molecules inside tumoral liver tissues has been shown by NMR measurements and confirmed by α spectroscopy. A new molecular Gd-tagged nanomagnet and BNCT agent (GdBPA) has been synthesized and characterized measuring its relaxivity R1 between 10 kHz and 66 MHz, and its use as a contrast agent in MRI has been demonstrated. The NMR-based evidence of the absorption of GdBPA into living tumoral cells is also shown.

  17. Monitoring the distribution of prompt gamma rays in boron neutron capture therapy using a multiple-scattering Compton camera: A Monte Carlo simulation study

    NASA Astrophysics Data System (ADS)

    Lee, Taewoong; Lee, Hyounggun; Lee, Wonho

    2015-10-01

    This study evaluated the use of Compton imaging technology to monitor prompt gamma rays emitted by 10B in boron neutron capture therapy (BNCT) applied to a computerized human phantom. The Monte Carlo method, including particle-tracking techniques, was used for simulation. The distribution of prompt gamma rays emitted by the phantom during irradiation with neutron beams is closely associated with the distribution of the boron in the phantom. Maximum likelihood expectation maximization (MLEM) method was applied to the information obtained from the detected prompt gamma rays to reconstruct the distribution of the tumor including the boron uptake regions (BURs). The reconstructed Compton images of the prompt gamma rays were combined with the cross-sectional images of the human phantom. Quantitative analysis of the intensity curves showed that all combined images matched the predetermined conditions of the simulation. The tumors including the BURs were distinguishable if they were more than 2 cm apart.

  18. Quantitative bioimaging of p-boronophenylalanine in thin liver tissue sections as a tool for treatment planning in boron neutron capture therapy.

    PubMed

    Reifschneider, Olga; Schütz, Christian L; Brochhausen, Christoph; Hampel, Gabriele; Ross, Tobias; Sperling, Michael; Karst, Uwe

    2015-03-01

    An analytical method using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) was developed and applied to assess enrichment of 10B-containing p-boronophenylalanine-fructose (BPA-f) and its pharmacokinetic distribution in human tissues after application for boron neutron capture therapy (BNCT). High spatial resolution (50 μm) and limits of detection in the low parts-per-billion range were achieved using a Nd:YAG laser of 213 nm wavelength. External calibration by means of 10B-enriched standards based on whole blood proved to yield precise quantification results. Using this calibration method, quantification of 10B in cancerous and healthy tissue was carried out. Additionally, the distribution of 11B was investigated, providing 10B enrichment in the investigated tissues. Quantitative imaging of 10B by means of LA-ICP-MS was demonstrated as a new option to characterise the efficacy of boron compounds for BNCT.

  19. Boron Neutron Capture Therapy - A Literature Review

    PubMed Central

    Nedunchezhian, Kavitaa; Thiruppathy, Manigandan; Thirugnanamurthy, Sarumathi

    2016-01-01

    Boron Neutron Capture Therapy (BNCT) is a radiation science which is emerging as a hopeful tool in treating cancer, by selectively concentrating boron compounds in tumour cells and then subjecting the tumour cells to epithermal neutron beam radiation. BNCT bestows upon the nuclear reaction that occurs when Boron-10, a stable isotope, is irradiated with low-energy thermal neutrons to yield α particles (Helium-4) and recoiling lithium-7 nuclei. A large number of 10 Boron (10B) atoms have to be localized on or within neoplastic cells for BNCT to be effective, and an adequate number of thermal neutrons have to be absorbed by the 10B atoms to maintain a lethal 10B (n, α) lithium-7 reaction. The most exclusive property of BNCT is that it can deposit an immense dose gradient between the tumour cells and normal cells. BNCT integrates the fundamental focusing perception of chemotherapy and the gross anatomical localization proposition of traditional radiotherapy. PMID:28209015

  20. An accelerator-based Boron Neutron Capture Therapy (BNCT) facility based on the 7Li(p,n)7Be

    NASA Astrophysics Data System (ADS)

    Musacchio González, Elizabeth; Martín Hernández, Guido

    2017-09-01

    BNCT (Boron Neutron Capture Therapy) is a therapeutic modality used to irradiate tumors cells previously loaded with the stable isotope 10B, with thermal or epithermal neutrons. This technique is capable of delivering a high dose to the tumor cells while the healthy surrounding tissue receive a much lower dose depending on the 10B biodistribution. In this study, therapeutic gain and tumor dose per target power, as parameters to evaluate the treatment quality, were calculated. The common neutron-producing reaction 7Li(p,n)7Be for accelerator-based BNCT, having a reaction threshold of 1880.4 keV, was considered as the primary source of neutrons. Energies near the reaction threshold for deep-seated brain tumors were employed. These calculations were performed with the Monte Carlo N-Particle (MCNP) code. A simple but effective beam shaping assembly (BSA) was calculated producing a high therapeutic gain compared to previously proposed facilities with the same nuclear reaction.

  1. Hybrid Calcium Phosphate-Polymeric Micelles Incorporating Gadolinium Chelates for Imaging-Guided Gadolinium Neutron Capture Tumor Therapy.

    PubMed

    Mi, Peng; Dewi, Novriana; Yanagie, Hironobu; Kokuryo, Daisuke; Suzuki, Minoru; Sakurai, Yoshinori; Li, Yanmin; Aoki, Ichio; Ono, Koji; Takahashi, Hiroyuki; Cabral, Horacio; Nishiyama, Nobuhiro; Kataoka, Kazunori

    2015-06-23

    Gadolinium (Gd) chelates-loaded nanocarriers have high potential for achieving magnetic resonance imaging (MRI)-guided Gd neutron capture therapy (GdNCT) of tumors. Herein, we developed calcium phosphate micelles hybridized with PEG-polyanion block copolymers, and incorporated with the clinical MRI contrast agent Gd-diethylenetriaminepentaacetic acid (Gd-DTPA/CaP). The Gd-DTPA/CaP were nontoxic to cancer cells at the concentration of 100 μM based on Gd-DTPA, while over 50% of the cancer cells were killed by thermal neutron irradiation at this concentration. Moreover, the Gd-DTPA/CaP showed a dramatically increased accumulation of Gd-DTPA in tumors, leading to the selective contrast enhancement of tumor tissues for precise tumor location by MRI. The enhanced tumor-to-blood distribution ratio of Gd-DTPA/CaP resulted in the effective suppression of tumor growth without loss of body weight, indicating the potential of Gd-DTPA/CaP for safe cancer treatment.

  2. Rapid Isolation of Viable Circulating Tumor Cells from Patient Blood Samples

    PubMed Central

    Hughes, Andrew D.; Mattison, Jeff; Powderly, John D.; Greene, Bryan T.; King, Michael R.

    2012-01-01

    Circulating tumor cells (CTC) are cells that disseminate from a primary tumor throughout the circulatory system and that can ultimately form secondary tumors at distant sites. CTC count can be used to follow disease progression based on the correlation between CTC concentration in blood and disease severity1. As a treatment tool, CTC could be studied in the laboratory to develop personalized therapies. To this end, CTC isolation must cause no cellular damage, and contamination by other cell types, particularly leukocytes, must be avoided as much as possible2. Many of the current techniques, including the sole FDA-approved device for CTC enumeration, destroy CTC as part of the isolation process (for more information see Ref. 2). A microfluidic device to capture viable CTC is described, consisting of a surface functionalized with E-selectin glycoprotein in addition to antibodies against epithelial markers3. To enhance device performance a nanoparticle coating was applied consisting of halloysite nanotubes, an aluminosilicate nanoparticle harvested from clay4. The E-selectin molecules provide a means to capture fast moving CTC that are pumped through the device, lending an advantage over alternative microfluidic devices wherein longer processing times are necessary to provide target cells with sufficient time to interact with a surface. The antibodies to epithelial targets provide CTC-specificity to the device, as well as provide a readily adjustable parameter to tune isolation. Finally, the halloysite nanotube coating allows significantly enhanced isolation compared to other techniques by helping to capture fast moving cells, providing increased surface area for protein adsorption, and repelling contaminating leukocytes3,4. This device is produced by a straightforward technique using off-the-shelf materials, and has been successfully used to capture cancer cells from the blood of metastatic cancer patients. Captured cells are maintained for up to 15 days in culture following isolation, and these samples typically consist of >50% viable primary cancer cells from each patient. This device has been used to capture viable CTC from both diluted whole blood and buffy coat samples. Ultimately, we present a technique with functionality in a clinical setting to develop personalized cancer therapies. PMID:22733259

  3. Derivation of capture probabilities for the corotation eccentric mean motion resonances

    NASA Astrophysics Data System (ADS)

    El Moutamid, Maryame; Sicardy, Bruno; Renner, Stéfan

    2017-08-01

    We study in this paper the capture of a massless particle into an isolated, first-order corotation eccentric resonance (CER), in the framework of the planar, eccentric and restricted three-body problem near a m + 1: m mean motion commensurability (m integer). While capture into Lindblad eccentric resonances (where the perturber's orbit is circular) has been investigated years ago, capture into CER (where the perturber's orbit is elliptic) has not yet been investigated in detail. Here, we derive the generic equations of motion near a CER in the general case where both the perturber and the test particle migrate. We derive the probability of capture in that context, and we examine more closely two particular cases: (I) if only the perturber is migrating, capture is possible only if the migration is outward from the primary. Notably, the probability of capture is independent of the way the perturber migrates outward; (II) if only the test particle is migrating, then capture is possible only if the algebraic value of its migration rate is a decreasing function of orbital radius. In this case, the probability of capture is proportional to the radial gradient of migration. These results differ from the capture into Lindblad eccentric resonance (LER), where it is necessary that the orbits of the perturber and the test particle converge for capture to be possible.

  4. A Typology for Modeling Processes in Clinical Guidelines and Protocols

    NASA Astrophysics Data System (ADS)

    Tu, Samson W.; Musen, Mark A.

    We analyzed the graphical representations that are used by various guideline-modeling methods to express process information embodied in clinical guidelines and protocols. From this analysis, we distilled four modeling formalisms and the processes they typically model: (1) flowcharts for capturing problem-solving processes, (2) disease-state maps that link decision points in managing patient problems over time, (3) plans that specify sequences of activities that contribute toward a goal, (4) workflow specifications that model care processes in an organization. We characterized the four approaches and showed that each captures some aspect of what a guideline may specify. We believe that a general guideline-modeling system must provide explicit representation for each type of process.

  5. Mathematical Modeling and Evaluation of Human Motions in Physical Therapy Using Mixture Density Neural Networks

    PubMed Central

    Vakanski, A; Ferguson, JM; Lee, S

    2016-01-01

    Objective The objective of the proposed research is to develop a methodology for modeling and evaluation of human motions, which will potentially benefit patients undertaking a physical rehabilitation therapy (e.g., following a stroke or due to other medical conditions). The ultimate aim is to allow patients to perform home-based rehabilitation exercises using a sensory system for capturing the motions, where an algorithm will retrieve the trajectories of a patient’s exercises, will perform data analysis by comparing the performed motions to a reference model of prescribed motions, and will send the analysis results to the patient’s physician with recommendations for improvement. Methods The modeling approach employs an artificial neural network, consisting of layers of recurrent neuron units and layers of neuron units for estimating a mixture density function over the spatio-temporal dependencies within the human motion sequences. Input data are sequences of motions related to a prescribed exercise by a physiotherapist to a patient, and recorded with a motion capture system. An autoencoder subnet is employed for reducing the dimensionality of captured sequences of human motions, complemented with a mixture density subnet for probabilistic modeling of the motion data using a mixture of Gaussian distributions. Results The proposed neural network architecture produced a model for sets of human motions represented with a mixture of Gaussian density functions. The mean log-likelihood of observed sequences was employed as a performance metric in evaluating the consistency of a subject’s performance relative to the reference dataset of motions. A publically available dataset of human motions captured with Microsoft Kinect was used for validation of the proposed method. Conclusion The article presents a novel approach for modeling and evaluation of human motions with a potential application in home-based physical therapy and rehabilitation. The described approach employs the recent progress in the field of machine learning and neural networks in developing a parametric model of human motions, by exploiting the representational power of these algorithms to encode nonlinear input-output dependencies over long temporal horizons. PMID:28111643

  6. Mathematical Modeling and Evaluation of Human Motions in Physical Therapy Using Mixture Density Neural Networks.

    PubMed

    Vakanski, A; Ferguson, J M; Lee, S

    2016-12-01

    The objective of the proposed research is to develop a methodology for modeling and evaluation of human motions, which will potentially benefit patients undertaking a physical rehabilitation therapy (e.g., following a stroke or due to other medical conditions). The ultimate aim is to allow patients to perform home-based rehabilitation exercises using a sensory system for capturing the motions, where an algorithm will retrieve the trajectories of a patient's exercises, will perform data analysis by comparing the performed motions to a reference model of prescribed motions, and will send the analysis results to the patient's physician with recommendations for improvement. The modeling approach employs an artificial neural network, consisting of layers of recurrent neuron units and layers of neuron units for estimating a mixture density function over the spatio-temporal dependencies within the human motion sequences. Input data are sequences of motions related to a prescribed exercise by a physiotherapist to a patient, and recorded with a motion capture system. An autoencoder subnet is employed for reducing the dimensionality of captured sequences of human motions, complemented with a mixture density subnet for probabilistic modeling of the motion data using a mixture of Gaussian distributions. The proposed neural network architecture produced a model for sets of human motions represented with a mixture of Gaussian density functions. The mean log-likelihood of observed sequences was employed as a performance metric in evaluating the consistency of a subject's performance relative to the reference dataset of motions. A publically available dataset of human motions captured with Microsoft Kinect was used for validation of the proposed method. The article presents a novel approach for modeling and evaluation of human motions with a potential application in home-based physical therapy and rehabilitation. The described approach employs the recent progress in the field of machine learning and neural networks in developing a parametric model of human motions, by exploiting the representational power of these algorithms to encode nonlinear input-output dependencies over long temporal horizons.

  7. Aptamer functionalized noble metal particles for bioanalytical and biomedical applications

    NASA Astrophysics Data System (ADS)

    Yasun, Emir

    Noble metal particles, especially gold (Au) and silver (Ag) have been exploited in a broad range of biological applications due to their unique intrinsic features that depend on their physical appearance or optoelectronic properties, which can be tuned with the change in the size or shape of those particles. Thus, this tunability enables gold nanoparticles (AuNPs) to be used in biomedical diagnostic and therapeutical applications. In photothermal therapy applications, nanomaterials, which can absorb efficiently in NIR region, are utilized since the healthy tissue or cells can't absorb at this spectral region. Among AuNPs, gold nanorods (AuNRs) are one of the best candidates for hyperthermia therapy of cancer cells with their high absorption cross-sections and tunable absorption maxima in NIR region. When this unique optical property is combined with the specificity against cancer cells utilized by aptamer conjugations, AuNRs become to be one of the most important nanoparticles employed in both cancer cell sensing and therapy. However, one drawback of AuNRs is having the surfactant CTAB on their surface, which can cause nonspecificity and cytotoxicity. In this research, the side effects of CTAB are passivated by BSA modification, where the nonspecificity and cytotoxicity are dramatically decreased prior to the NIR treatment. Recognition of changes in the rare cancer protein abundances can lead the early diagnosis of cancer, so capturing these low abundance proteins has a great significance. In this research, firstly, aptamer conjugated AuNRs were used to capture 1ng of a-thrombin effectively from plasma samples as model system. Then both aptamer conjugated AuNRs and silver microspheres (SMSs) are used to capture the biomarker proteins of a colon cancer cell line, DLD-1. Gold and silver surfaces can easily be modified through thiolate chemistry, compared to the tedious modification steps for the magnetic particles, so more aptamer immobilization can be achieved for AuNRs and SMSs, which can increase the possibility of binding to the target protein. Furthermore, SMSs offer a novel separation method, gravitational separation owing to their heavy nature. In this way, there is no need for an external stimuli to separate the captured proteins and protein isolation can take only seconds.

  8. Two-proton capture on the 68Se nucleus with a new self-consistent cluster model

    NASA Astrophysics Data System (ADS)

    Hove, D.; Garrido, E.; Jensen, A. S.; Sarriguren, P.; Fynbo, H. O. U.; Fedorov, D. V.; Zinner, N. T.

    2018-07-01

    We investigate the two-proton capture reaction of the prominent rapid proton capture waiting point nucleus, 68Se, that produces the borromean nucleus 70Kr (68Se + p + p). We apply a recently formulated general model where the core nucleus, 68Se, is treated in the mean-field approximation and the three-body problem of the two valence protons and the core is solved exactly. We compare using two popular Skyrme interactions, SLy4 and SkM*. We calculate E2 electromagnetic two-proton dissociation and capture cross sections, and derive the temperature dependent capture rates. We vary the unknown 2+ resonance energy without changing any of the structures computed self-consistently for both core and valence particles. We find rates increasing quickly with temperature below 2-4 GK after which we find rates varying by about a factor of two independent of 2+ resonance energy. The capture mechanism is sequential through the f5/2 proton-core resonance, but the continuum background contributes significantly.

  9. Broad-search algorithms for finding triple-and quadruple-satellite-aided captures at Jupiter from 2020 to 2080

    NASA Astrophysics Data System (ADS)

    Lynam, Alfred E.

    2015-04-01

    Multiple-satellite-aided capture is a -efficient technique for capturing a spacecraft into orbit at Jupiter. However, finding the times when the Galilean moons of Jupiter align such that three or four of them can be encountered in a single pass is difficult using standard astrodynamics algorithms such as Lambert's problem. In this paper, we present simple but powerful techniques that simplify the dynamics and geometry of the Galilean satellites so that many of these triple- and quadruple-satellite-aided capture sequences can be found quickly over an extended 60-year time period from 2020 to 2080. The techniques find many low-fidelity trajectories that could be used as initial guesses for future high-fidelity optimization. Results indicate the existence of approximately 3,100 unique triple-satellite-aided capture trajectories and 6 unique quadruple-satellite-aided capture trajectories during the 60-year time period. The entire search takes less than one minute of computational time.

  10. Cancer rehabilitation with a focus on evidence-based outpatient physical and occupational therapy interventions.

    PubMed

    Silver, Julie K; Gilchrist, Laura S

    2011-05-01

    Cancer rehabilitation is an important part of survivorship as a distinct phase of treatment. Although cancer rehabilitation may involve many disciplines, this article specifically covers evidence-based treatment in physical and occupational therapy. Patients may need physical and occupational therapy services for a variety of cancer-related or cancer-treatment-related problems, including pain, fatigue, deconditioning, and difficulty with gait. They may also have problems resuming their previous level of function, which can impact on activities of daily living, instrumental activities of daily living, return to previous home and community activity levels, and return to work. This review discusses the role of physical and occupational therapy in helping cancer patients improve pain and musculoskeletal issues, deconditioning and endurance effects, fatigue, balance and falls, and lymphedema and psychosocial problems.

  11. Targeting Ballistic Lunar Capture Trajectories Using Periodic Orbits in the Sun-Earth CRTBP

    NASA Technical Reports Server (NTRS)

    Cooley, D.S.; Griesemer, Paul Ricord; Ocampo, Cesar

    2009-01-01

    A particular periodic orbit in the Earth-Sun circular restricted three body problem is shown to have the characteristics needed for a ballistic lunar capture transfer. An injection from a circular parking orbit into the periodic orbit serves as an initial guess for a targeting algorithm. By targeting appropriate parameters incrementally in increasingly complicated force models and using precise derivatives calculated from the state transition matrix, a reliable algorithm is produced. Ballistic lunar capture trajectories in restricted four body systems are shown to be able to be produced in a systematic way.

  12. Microdosimetry: Principles and applications

    PubMed Central

    Santa Cruz, Gustavo A.

    2016-01-01

    Aim to present the most important aspects of Microdosimetry, a research field in radiation biophysics. Background microdosimetry is the branch of radiation biophysics that systematically studies the spatial, temporal and spectral aspects of the stochastic nature of the energy deposition processes in microscopic structures. Materials and Methods we briefly review its history, the people, the formalism and the theories and devices that allowed researchers to begin to understand the true nature of radiation action on living matter. Results and Conclusions we outline some of its applications, especially to Boron Neutron Capture Therapy, attempting to explain the biological effectiveness of the boron thermal neutron capture reaction. PMID:26933397

  13. Youth social behaviour and network therapy (Y-SBNT): adaptation of a family and social network intervention for young people who misuse alcohol and drugs - a randomised controlled feasibility trial.

    PubMed

    Watson, Judith; Toner, Paul; Day, Ed; Back, Donna; Brady, Louca-Mai; Fairhurst, Caroline; Renwick, Charlotte; Templeton, Lorna; Akhtar, Shabana; Lloyd, Charlie; Li, Jinshuo; Cocks, Kim; Ambegaokar, Sangeeta; Parrott, Steve; McArdle, Paul; Gilvarry, Eilish; Copello, Alex

    2017-03-01

    Family interventions appear to be effective at treating young people's substance misuse. However, implementation of family approaches in UK services is low. This study aimed to demonstrate the feasibility of recruiting young people to an intervention based on an adaptation of adult social behaviour and network therapy. It also sought to involve young people with experience of using substance misuse services in the research process. To demonstrate the feasibility of recruiting young people to family and social network therapy and to explore ways in which young people with experience of using substance misuse services could be involved in a study of this nature. A pragmatic, two-armed, randomised controlled open feasibility trial. Two UK-based treatment services for young people with substance use problems, with recruitment taking place from May to November 2014. Young people aged 12-18 years, newly referred and accepted for structured interventions for drug and/or alcohol problems. A remote, web-based computer randomisation system allocated young people to adapted youth social behaviour and network therapy (Y-SBNT) or treatment as usual (TAU). Y-SBNT participants were intended to receive up to six 50-minute sessions over a maximum of 12 weeks. TAU participants continued to receive usual care delivered by their service. Feasibility was measured by recruitment rates, retention in treatment and follow-up completion rates. The main clinical outcome was the proportion of days on which the main problem substance was used in the preceding 90-day period as captured by the Timeline Follow-Back interview at 3 and 12 months. In total, 53 young people were randomised (Y-SBNT, n  = 26; TAU, n  = 27) against a target of 60 (88.3%). Forty-two young people attended at least one treatment session [Y-SBNT 22/26 (84.6%); TAU 20/27 (74.1%)]; follow-up rates were 77.4% at month 3 and 73.6% at month 12. Data for nine young people were missing at both months 3 and 12, so the main clinical outcome analysis was based on 24 young people (92.3%) in the Y-SBNT group and 20 young people (74.1%) in the TAU group. At month 12, the average proportion of days that the main problem substance was used in the preceding 90 days was higher in the Y-SBNT group than in the TAU group (0.54 vs. 0.41; adjusted mean difference 0.13, 95% confidence interval -0.12 to 0.39; p  = 0.30). No adverse events were reported. Seventeen young people with experience of substance misuse services were actively involved throughout the study. They informed key elements of the intervention and research process, ensuring that the intervention was acceptable and relevant to our target groups; contributing to the design of key trial documents, ideas for a new model of public involvement and this report. Two parents were also involved. The adapted intervention could be delivered in young people's services, and qualitative interviews found that Y-SBNT was acceptable to young people, family members and staff. Engagement of family and network members proved difficult within the intervention and research aspects. The study proved the feasibility of this work in routine services but outcome measurement based on narrow substance use variables may be limited and may fail to capture other important changes in wider areas of functioning for young people. Validation of the EuroQol-5 Dimensions for young people aged 12-18 years should be considered and flexible models for involvement of young people in research are required to achieve inclusive representation throughout all aspects of the research process. Although recommendation of a full trial of the Y-SBNT intervention compared with TAU is not supported, this study can inform future intervention development and UK research within routine addiction services. Current Controlled Trials ISRCTN93446265. This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment ; Vol. 21, No. 15. See the NIHR Journals Library website for further project information.

  14. The efficacy of problem-solving treatments after deliberate self-harm: meta-analysis of randomized controlled trials with respect to depression, hopelessness and improvement in problems.

    PubMed

    Townsend, E; Hawton, K; Altman, D G; Arensman, E; Gunnell, D; Hazell, P; House, A; Van Heeringen, K

    2001-08-01

    Brief problem-solving therapy is regarded as a pragmatic treatment for deliberate self-harm (DSH) patients. A recent meta-analysis of randomized controlled trials (RCTs) evaluating this approach indicated a trend towards reduced repetition of DSH but the pooled odds ratio was not statistically significant. We have now examined other important outcomes using this procedure, namely depression, hopelessness and improvement in problems. Six trials in which problem-solving therapy was compared with control treatment were identified from an extensive literature review of RCTs of treatments for DSH patients. Data concerning depression, hopelessness and improvement in problems were extracted. Where relevant statistical data (e.g. standard deviations) were missing these were imputed using various statistical methods. Results were pooled using meta-analytical procedures. At follow-up, patients who were offered problem-solving therapy had significantly greater improvement in scores for depression (standardized mean difference = -0.36; 95% CI -0.61 to -0.11) and hopelessness (weighted mean difference =-3.2; 95% CI -4.0 to -2.41), and significantly more reported improvement in their problems (odds ratio = 2.31; 95% CI 1.29 to 4.13), than patients who were in the control treatment groups. Problem-solving therapy for DSH patients appears to produce better results than control treatment with regard to improvement in depression, hopelessness and problems. It is desirable that this finding is confirmed in a large trial, which will also allow adequate testing of the impact of this treatment on repetition of DSH.

  15. An Assessment of the Potential Use of BNNTs for Boron Neutron Capture Therapy.

    PubMed

    Ferreira, Tiago H; Miranda, Marcelo C; Rocha, Zildete; Leal, Alexandre S; Gomes, Dawidson A; Sousa, Edesia M B

    2017-04-12

    Currently, nanostructured compounds have been standing out for their optical, mechanical, and chemical features and for the possibilities of manipulation and regulation of complex biological processes. One of these compounds is boron nitride nanotubes (BNNTs), which are a nanostructured material analog to carbon nanotubes, but formed of nitrogen and boron atoms. BNNTs present high thermal stability along with high chemical inertia. Among biological applications, its biocompatibility, cellular uptake, and functionalization potential can be highlighted, in addition to its eased utilization due to its nanometric size and tumor cell internalization. When it comes to new forms of therapy, we can draw attention to boron neutron capture therapy (BNCT), an experimental radiotherapy characterized by a boron-10 isotope carrier inside the target and a thermal neutron beam focused on it. The activation of the boron-10 atom by a neutron generates a lithium atom, a gamma ray, and an alpha particle, which can be used to destroy tumor tissues. The aim of this work was to use BNNTs as a boron-10 carrier for BNCT and to demonstrate its potential. The nanomaterial was characterized through XRD, FTIR, and SEM. The WST-8 assay was performed to confirm the cell viability of BNNTs. The cells treated with BNNTs were irradiated with the neutron beam of a Triga reactor, and the apoptosis caused by the activation of the BNNTs was measured with a calcein AM/propidium iodide test. The results demonstrate that this nanomaterial is a promising candidate for cancer therapy through BNCT.

  16. Application of an incident taxonomy for radiation therapy: Analysis of five years of data from three integrated cancer centres.

    PubMed

    Greenham, Stuart; Manley, Stephen; Turnbull, Kirsty; Hoffmann, Matthew; Fonseca, Amara; Westhuyzen, Justin; Last, Andrew; Aherne, Noel J; Shakespeare, Thomas P

    2018-01-01

    To develop and apply a clinical incident taxonomy for radiation therapy. Capturing clinical incident information that focuses on near-miss events is critical for achieving higher levels of safety and reliability. A clinical incident taxonomy for radiation therapy was established; coding categories were prescription, consent, simulation, voluming, dosimetry, treatment, bolus, shielding, imaging, quality assurance and coordination of care. The taxonomy was applied to all clinical incidents occurring at three integrated cancer centres for the years 2011-2015. Incidents were managed locally, audited and feedback disseminated to all centres. Across the five years the total incident rate (per 100 courses) was 8.54; the radiotherapy-specific coded rate was 6.71. The rate of true adverse events (unintended treatment and potential patient harm) was 1.06. Adverse events, where no harm was identified, occurred at a rate of 2.76 per 100 courses. Despite workload increases, overall and actual rates both exhibited downward trends over the 5-year period. The taxonomy captured previously unidentified quality assurance failures; centre-specific issues that contributed to variations in incident trends were also identified. The application of a taxonomy developed for radiation therapy enhances incident investigation and facilitates strategic interventions. The practice appears to be effective in our institution and contributes to the safety culture. The ratio of near miss to actual incidents could serve as a possible measure of incident reporting culture and could be incorporated into large scale incident reporting systems.

  17. Circulating Tumor Cells: What Is in It for the Patient? A Vision towards the Future

    PubMed Central

    van de Stolpe, Anja; den Toonder, Jaap M. J.

    2014-01-01

    Knowledge on cellular signal transduction pathways as drivers of cancer growth and metastasis has fuelled development of “targeted therapy” which “targets” aberrant oncogenic signal transduction pathways. These drugs require nearly invariably companion diagnostic tests to identify the tumor-driving pathway and the cause of the abnormal pathway activity in a tumor sample, both for therapy response prediction as well as for monitoring of therapy response and emerging secondary drug resistance. Obtaining sufficient tumor material for this analysis in the metastatic setting is a challenge, and circulating tumor cells (CTCs) may provide an attractive alternative to biopsy on the premise that they can be captured from blood and the companion diagnostic test results are correctly interpreted. We discuss novel companion diagnostic directions, including the challenges, to identify the tumor driving pathway in CTCs, which in combination with a digital pathology platform and algorithms to quantitatively interpret complex CTC diagnostic results may enable optimized therapy response prediction and monitoring. In contrast to CTC-based companion diagnostics, CTC enumeration is envisioned to be largely replaced by cell free tumor DNA measurements in blood for therapy response and recurrence monitoring. The recent emergence of novel in vitro human model systems in the form of cancer-on-a-chip may enable elucidation of some of the so far elusive characteristics of CTCs, and is expected to contribute to more efficient CTC capture and CTC-based diagnostics. PMID:24879438

  18. DEVELOPMENT OF A MULTIMODAL MONTE CARLO BASED TREATMENT PLANNING SYSTEM.

    PubMed

    Kumada, Hiroaki; Takada, Kenta; Sakurai, Yoshinori; Suzuki, Minoru; Takata, Takushi; Sakurai, Hideyuki; Matsumura, Akira; Sakae, Takeji

    2017-10-26

    To establish boron neutron capture therapy (BNCT), the University of Tsukuba is developing a treatment device and peripheral devices required in BNCT, such as a treatment planning system. We are developing a new multimodal Monte Carlo based treatment planning system (developing code: Tsukuba Plan). Tsukuba Plan allows for dose estimation in proton therapy, X-ray therapy and heavy ion therapy in addition to BNCT because the system employs PHITS as the Monte Carlo dose calculation engine. Regarding BNCT, several verifications of the system are being carried out for its practical usage. The verification results demonstrate that Tsukuba Plan allows for accurate estimation of thermal neutron flux and gamma-ray dose as fundamental radiations of dosimetry in BNCT. In addition to the practical use of Tsukuba Plan in BNCT, we are investigating its application to other radiation therapies. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Occurrence of simultaneous cathodal-anodal capture with left ventricular quadripolar leads for cardiac resynchronization therapy: an electrocardiogram evaluation.

    PubMed

    Occhetta, Eraldo; Dell'Era, Gabriele; Giubertoni, Ailia; Magnani, Andrea; Rametta, Francesco; Blandino, Alessandro; Magnano, Vincenzo; Malacrida, Maurizio; Marino, Paolo

    2017-04-01

    The occurrence of left ventricular (LV) anodal activation during pacing with modern multipolar cardiac resynchronization therapy (CRT) systems has never been reported. The aim of our study was to demonstrate, by means of electrocardiogram (ECG) analysis, the occurrence of simultaneous cathodal-anodal LV capture with quadripolar LV leads. We studied 10 first-time recipients of a CRT device equipped with a quadripolar LV lead. During follow-up, standard supine 12-lead ECGs were obtained in available cathode-to-anode LV pacing configurations with a pulse amplitude equal to twice the pacing threshold. The occurrence of simultaneous cathodal-anodal LV capture was defined as the presence of variations in electrocardiographic ventricular activation (EVA) when the distal tip (cathode)-to-device can (anode) pacing configuration was compared with the distal tip (cathode)-to-proximal ring (anode) configuration. In eight patients, we found differences in EVA when different LV sites were paced through the unipolar LV tip and unipolar LV ring configurations. In these patients, a difference in EVA was detected in 61.5% (59 of 96) of the ECG leads (marked difference in 31.3%, slight difference in 30.2%). Changes in EVA between unipolar tip-to-can and bipolar tip-to-ring pacing that were suggestive of cathodal-anodal LV capture were found in six patients. In these patients, a total of 30 (41.7%) ECG leads showed a difference in EVA (marked difference in 20.8%, slight difference in 20.8%). In our experience, additional anodal capture by the proximal LV ring during LV pacing is provable in most recipients of a resynchronization device equipped with a multipolar LV lead. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  20. Capturing and stitching images with a large viewing angle and low distortion properties for upper gastrointestinal endoscopy

    NASA Astrophysics Data System (ADS)

    Liu, Ya-Cheng; Chung, Chien-Kai; Lai, Jyun-Yi; Chang, Han-Chao; Hsu, Feng-Yi

    2013-06-01

    Upper gastrointestinal endoscopies are primarily performed to observe the pathologies of the esophagus, stomach, and duodenum. However, when an endoscope is pushed into the esophagus or stomach by the physician, the organs behave similar to a balloon being gradually inflated. Consequently, their shapes and depth-of-field of images change continually, preventing thorough examination of the inflammation or anabrosis position, which delays the curing period. In this study, a 2.9-mm image-capturing module and a convoluted mechanism was incorporated into the tube like a standard 10- mm upper gastrointestinal endoscope. The scale-invariant feature transform (SIFT) algorithm was adopted to implement disease feature extraction on a koala doll. Following feature extraction, the smoothly varying affine stitching (SVAS) method was employed to resolve stitching distortion problems. Subsequently, the real-time splice software developed in this study was embedded in an upper gastrointestinal endoscope to obtain a panoramic view of stomach inflammation in the captured images. The results showed that the 2.9-mm image-capturing module can provide approximately 50 verified images in one spin cycle, a viewing angle of 120° can be attained, and less than 10% distortion can be achieved in each image. Therefore, these methods can solve the problems encountered when using a standard 10-mm upper gastrointestinal endoscope with a single camera, such as image distortion, and partial inflammation displays. The results also showed that the SIFT algorithm provides the highest correct matching rate, and the SVAS method can be employed to resolve the parallax problems caused by stitching together images of different flat surfaces.

  1. Pharmacist care plans and documentation of follow-up before the Iowa Pharmaceutical Case Management program.

    PubMed

    Becker, CoraLynn; Bjornson, Darrel C; Kuhle, Julie W

    2004-01-01

    To document drug therapy problems and their causes and assess pharmacist follow-up of patients with identified drug therapy problems. Cross-sectional analysis. Iowa. 160 pharmacists who submitted 754 pharmaceutical care plans in an effort to qualify for participation in the Iowa Pharmaceutical Case Management program. Care plans were assessed for drug therapy problems and causes and for documentation of pharmacist follow-up (actual, none, or intent to follow up). Pharmacists documented a wide variety of drug therapy problems and causes, including adverse drug reactions (20.1% of care plans), need for additional drug therapy (18.9%), lack of patient adherence to therapy (16.3%), incorrect medication being prescribed (14.1%), and drug dose too high (10.0%). Pharmacist follow-up with patients was not optimal, with 31% of care plans providing documentation of actual follow-up. Another 42.2% of plans indicated that the pharmacist intended to contact the patient for follow-up but either did not do so or did not record the intervention. No actual follow-up or intent to follow up was recorded in 26.8% of care plans. Pharmacists practicing in independent pharmacies followed up with patients more frequently than those in other settings (36.4% of care plans, compared with 22.7%, 23.2%, and 28.4% for chain, clinic, and franchise pharmacies). Pharmacists were more likely to follow up when the identified problem involved drug safety rather than effectiveness (36.2% versus 28.3% of care plans). Documentation of pharmacist follow-up with patients was less than optimal. In addition to identifying drug therapy problems and causes, pharmacists must complete the care continuum through documentation of patient monitoring and follow-up to transform the philosophy and vision of the pharmaceutical care concept into a practice of pharmacy recognized and rewarded by patients and payers.

  2. Capture of planetesimals into a circumterrestrial swarm

    NASA Technical Reports Server (NTRS)

    Weidenschilling, S. J.

    1984-01-01

    The lunar origin model considered involves processing of protolunar material through a circumterrestrial swarm of particles. Once such a swarm has formed, it can gain mass by capturing infalling planetesimals and ejecta from giant impacts on the Earth, although the angular momentum supply from these sources remains a problem. Examined is the first stage of formation of a geocentric swarm by capture of planetesimals from initialy heliocentric orbits. The only plausible capture mechanism that is not dependent on very low approach velocities is the mutual collision of planetesimals passing within Earth's sphere of influence. This capture scenario was tested directly by many body numerical integration of planetesimal orbits in near Earth space. Results agree that the systematic contribution of angular momentum is insufficient to maintain an orbiting swarm under heavy bombardment. Thus, a circumterrestrial swarm can be formed rather easily, but is hard to sustain because the mean net angular momentum of a many body swarm is small.

  3. FlyCap: Markerless Motion Capture Using Multiple Autonomous Flying Cameras.

    PubMed

    Xu, Lan; Liu, Yebin; Cheng, Wei; Guo, Kaiwen; Zhou, Guyue; Dai, Qionghai; Fang, Lu

    2017-07-18

    Aiming at automatic, convenient and non-instrusive motion capture, this paper presents a new generation markerless motion capture technique, the FlyCap system, to capture surface motions of moving characters using multiple autonomous flying cameras (autonomous unmanned aerial vehicles(UAVs) each integrated with an RGBD video camera). During data capture, three cooperative flying cameras automatically track and follow the moving target who performs large-scale motions in a wide space. We propose a novel non-rigid surface registration method to track and fuse the depth of the three flying cameras for surface motion tracking of the moving target, and simultaneously calculate the pose of each flying camera. We leverage the using of visual-odometry information provided by the UAV platform, and formulate the surface tracking problem in a non-linear objective function that can be linearized and effectively minimized through a Gaussian-Newton method. Quantitative and qualitative experimental results demonstrate the plausible surface and motion reconstruction results.

  4. Reaching the Problem Child Through Psychological Techniques as an Aid to Elementary School Counselors

    ERIC Educational Resources Information Center

    Campanelle, Thomas; Hawkey, Helen

    1973-01-01

    This discussion outlines the techniques used in play therapy. Play therapy helps children to express verbally their innermost concerns, thus offering the counselor a way of understanding and helping the child who may have emotional or learning problems. (JC)

  5. Interpersonal Circumplex Profiles Of Persistent Depression: Goals, Self-Efficacy, Problems, And Effects Of Group Therapy.

    PubMed

    Locke, Kenneth D; Sayegh, Liliane; Penberthy, J Kim; Weber, Charlotte; Haentjens, Katherine; Turecki, Gustavo

    2017-06-01

    We assessed severely and persistently depressed patients' interpersonal self-efficacy, problems, and goals, plus changes in interpersonal functioning and depression during 20 weeks of group therapy. Outpatients (32 female, 26 male, mean age = 45 years) completed interpersonal circumplex measures of goals, efficacy, and problems before completing 20 weeks of manualized group therapy, during which we regularly assessed depression and interpersonal style. Compared to normative samples, patients lacked interpersonal agency, including less self-efficacy for expressive/assertive actions; stronger motives to avoid conflict, scorn, and humiliation; and more problems with being too submissive, inhibited, and accommodating. Behavioral Activation and especially Cognitive Behavioral Analysis System of Psychotherapy interventions produced improvements in depression and interpersonal agency, with increases in "agentic and communal" efficacy predicting subsequent decreases in depression. While severely and persistently depressed patients were prone to express maladaptive interpersonal dispositions, over the course of group therapy, they showed increasingly agentic and beneficial patterns of cognitions, motives, and behaviors. © 2016 Wiley Periodicals, Inc.

  6. Patient baseline interpersonal problems as moderators of outcome in two psychotherapies for bulimia nervosa.

    PubMed

    Gomez Penedo, Juan Martin; Constantino, Michael J; Coyne, Alice E; Bernecker, Samantha L; Smith-Hansen, Lotte

    2018-01-19

    We tested an aptitude by treatment interaction; namely, whether patients' baseline interpersonal problems moderated the comparative efficacy of cognitive-behavioral therapy (CBT) vs. interpersonal psychotherapy (IPT) for bulimia nervosa (BN). Data derived from a randomized-controlled trial. Patients reported on their interpersonal problems at baseline; purge frequency at baseline, midtreatment, and posttreatment; and global eating disorder severity at baseline and posttreatment. We estimated the rate of change in purge frequency across therapy, and the likelihood of attaining clinically meaningful improvement (recovery) in global eating disorder severity by posttreatment. We then tested the interpersonal problem by treatment interactions as predictors of both outcomes. Patients with more baseline overly communal/friendly problems showed steeper reduction in likelihood of purging when treated with CBT vs. IPT. Patients with more problems of being under communal/cold had similar reductions in likelihood of purging across both treatments. Patients with more baseline problems of being overly agentic were more likely to recover when treated with IPT vs. CBT, whereas patients with more problems of being under agentic were more likely to recover when treated with CBT vs. IPT. Interpersonal problems related to communion and agency may inform treatment fit among two empirically supported therapies for BN.

  7. A Project of Boron Neutron Capture Therapy System based on a Proton Linac Neutron Source

    NASA Astrophysics Data System (ADS)

    Kiyanagi, Yoshikai; Asano, Kenji; Arakawa, Akihiro; Fukuchi, Shin; Hiraga, Fujio; Kimura, Kenju; Kobayashi, Hitoshi; Kubota, Michio; Kumada, Hiroaki; Matsumoto, Hiroshi; Matsumoto, Akira; Sakae, Takeji; Saitoh, Kimiaki; Shibata, Tokushi; Yoshioka, Masakazu

    At present, the clinical trials of Boron Neutron Capture Therapy (BNCT) are being performed at research reactor facilities. However, an accelerator based BNCT has a merit that it can be built in a hospital. So, we just launched a development project for the BNCT based on an accelerator in order to establish and to spread the BNCT as an effective therapy in the near future. In the project, a compact proton linac installed in a hospital will be applied as a neutron source, and energy of the proton beam is planned to be less than about 10 MeV to reduce the radioactivity. The BNCT requires epithermal neutron beam with an intensity of around 1x109 (n/cm2/sec) to deliver the therapeutic dose to a deeper region in a body and to complete the irradiation within an hour. From this condition, the current of the proton beam required is estimated to be a few mA on average. Enormous heat deposition in the target is a big issue. We are aiming at total optimization of the accelerator based BNCT from the linac to the irradiation position. Here, the outline of the project is introduced and the moderator design is presented.

  8. Boron neutron capture therapy induces cell cycle arrest and cell apoptosis of glioma stem/progenitor cells in vitro.

    PubMed

    Sun, Ting; Zhang, Zizhu; Li, Bin; Chen, Guilin; Xie, Xueshun; Wei, Yongxin; Wu, Jie; Zhou, Youxin; Du, Ziwei

    2013-08-06

    Glioma stem cells in the quiescent state are resistant to clinical radiation therapy. An almost inevitable glioma recurrence is due to the persistence of these cells. The high linear energy transfer associated with boron neutron capture therapy (BNCT) could kill quiescent and proliferative cells. The present study aimed to evaluate the effects of BNCT on glioma stem/progenitor cells in vitro. The damage induced by BNCT was assessed using cell cycle progression, apoptotic cell ratio and apoptosis-associated proteins expression. The surviving fraction and cell viability of glioma stem/progenitor cells were decreased compared with differentiated glioma cells using the same boronophenylalanine pretreatment and the same dose of neutron flux. BNCT induced cell cycle arrest in the G2/M phase and cell apoptosis via the mitochondrial pathway, with changes in the expression of associated proteins. Glioma stem/progenitor cells, which are resistant to current clinical radiotherapy, could be effectively killed by BNCT in vitro via cell cycle arrest and apoptosis using a prolonged neutron irradiation, although radiosensitivity of glioma stem/progenitor cells was decreased compared with differentiated glioma cells when using the same dose of thermal neutron exposure and boronophenylalanine pretreatment. Thus, BNCT could offer an appreciable therapeutic advantage to prevent tumor recurrence, and may become a promising treatment in recurrent glioma.

  9. Multi-Family Pediatric Pain Group Therapy: Capturing Acceptance and Cultivating Change.

    PubMed

    Huestis, Samantha E; Kao, Grace; Dunn, Ashley; Hilliard, Austin T; Yoon, Isabel A; Golianu, Brenda; Bhandari, Rashmi P

    2017-12-07

    Behavioral health interventions for pediatric chronic pain include cognitive-behavioral (CBT), acceptance and commitment (ACT), and family-based therapies, though literature regarding multi-family therapy (MFT) is sparse. This investigation examined the utility and outcomes of the Courage to Act with Pain: Teens Identifying Values, Acceptance, and Treatment Effects (CAPTIVATE) program, which included all three modalities (CBT, ACT, MFT) for youth with chronic pain and their parents. Program utility, engagement, and satisfaction were evaluated via quantitative and qualitative feedback. Pain-specific psychological, behavioral, and interpersonal processes were examined along with outcomes related to disability, quality of life, pain interference, fatigue, anxiety, and depressive symptoms. Participants indicated that CAPTIVATE was constructive, engaging, and helpful for social and family systems. Clinical and statistical improvements with large effect sizes were captured for pain catastrophizing, acceptance, and protective parenting but not family functioning. Similar effects were found for functional disability, pain interference, fatigue, anxiety, and depression. Given the importance of targeting multiple systems in the management of pediatric chronic pain, preliminary findings suggest a potential new group-based treatment option for youth and families. Next steps involve evaluating the differential effect of the program over treatment as usual, as well as specific CBT, ACT, and MFT components and processes that may affect outcomes.

  10. Therapist Adherence in Brief Strategic Family Therapy for Adolescent Drug Abusers

    PubMed Central

    Robbins, Michael S.; Feaster, Daniel J.; Horigian, Viviana E.; Puccinelli, Marc J.; Henderson, Craig; Szapocznik, José

    2012-01-01

    Objective Therapist adherence has been shown to predict clinical outcomes in family therapy. In prior studies, adherence has been represented broadly by core principles and a consistent family (vs. individual) focus. To date, these studies have not captured the range of clinical skills that are represented in complex family-based approaches or examined how variations in these skills predict different clinically relevant outcomes over the course of treatment. In this study, the authors examined the reliability and validity of an observational adherence measure and the relationship between adherence and outcome in a sample of drug-using adolescents who received brief strategic family therapy within a multisite effectiveness study. Method Participants were 480 adolescents (age 12–17) and their family members, who were randomized to the Brief Strategic Family Therapist treatment condition (J. Szapocznik, U. Hervis, & S. Schwartz, 2003) or treatment as usual. The adolescents were mostly male (377 vs. 103 female) and Hispanic (213), whereas 148 were White, and 110 were Black. Therapists were also randomly assigned to treatment condition within agencies. Results Results supported the proposed factor structure of the adherence measure, providing evidence that it is possible to capture and discriminate between distinct dimensions of family therapy. Analyses demonstrated that the mean levels of the factors varied over time in theoretically and clinically relevant ways and that therapist adherence was associated with engagement and retention in treatment, improvements in family functioning, and reductions in adolescent drug use. Conclusions Clinical implications and future research directions are discussed, including the relevance of these findings on training therapists and studies focusing on mechanisms of action in family therapy. PMID:21261433

  11. A Randomized Controlled Trial of Problem-Solving Therapy Compared to Cognitive Therapy for the Treatment of Insomnia in Adults

    PubMed Central

    Pech, Melissa; O'Kearney, Richard

    2013-01-01

    Study Objectives: To compare the efficacy of problem-solving therapy (PST) combined with behavioral sleep strategies to standard cognitive therapy (CT) combined with behavioral sleep strategies in the treatment of insomnia. Design: A six-week randomized controlled trial with one month follow-up. Setting: The Australian National University Psychology Clinic, Canberra, Australia. Participants: Forty-seven adults aged 18-60 years recruited from the community meeting the Research Diagnostic Criteria for insomnia. Interventions: Participants received 6 weeks of treatment including one group session (sleep education and hygiene, stimulus control instructions and progressive muscle relaxation) followed by 5 weeks of individual treatment of PST or CT. Measurements and Results: Primary outcomes included sleep efficiency (SE) from sleep diaries, the Insomnia Severity Index (ISI), and the Pittsburgh Sleep Quality Index (PSQI). Secondary measures assessed dysfunctional sleep beliefs, problem-solving skills and orientations, and worry. Both treatments produced significant post therapy improvements in sleep which were maintained at 1 month follow-up (on SE Cohen d = 1.42, 95% CI 1.02-1.87 for PST; d = 1.26, 95% CI 0.81-1.65 for CT; on ISI d = 1.46, 95% CI 1.03-1.88 for PST; d = 1.95, 95% CI 0.52-2.38 for CT; for PSQI d = 0.97, 95% CI 0.55-1.40 for PST and d = 1.34, 95% CI 0.90-1.79 for the CT). There were no differences in PST and CT in the size or rate of improvement in sleep although CT produced a significant faster rate of decline in negative beliefs about sleep than PST and there was a trend (P = 0.08) for PST to produce a faster rate of improvement in negative problem orientation than CT. Conclusions: The results provide preliminary support for problem solving treatment as an equally efficacious alternative component to cognitive therapy in psychological interventions for insomnia. Citation: Pech M; O'Kearney R. A randomized controlled trial of problem-solving therapy compared to cognitive therapy for the treatment of insomnia in adults. SLEEP 2013;36(5):739-749. PMID:23633757

  12. Lecture-Capture Software and the Teaching of Soils

    NASA Astrophysics Data System (ADS)

    Brevik, Eric C.

    2014-05-01

    Several companies now offer software that can record academic lectures and place them on password-protected course websites for future review by students. Using lecture-capture software offers several advantages for the instructor and the students, including: 1) The ability for students who miss class for legitimate reasons (e.g., participation in school-sanctioned extra-curricular activities, illness or family emergencies) to get lecture materials by logging into the class website. This provides these students with a more complete exposure to the material than simply copying a classmate's notes. 2) The instructor is able to direct students who miss class for legitimate reasons to the recorded lecture rather than needing to spend time going over the material with those students and that recap does not end up being rushed. 3) The ability to address course conflicts for graduating seniors by allowing them to take the lecture portion of the class via recorded lecture. 4) Students who desire more in-depth learning are able to go back to selected portions of previous lectures to review and reconsider a topic of discussion or to fill in vague sections of their notes. There are also potential disadvantages to the use of lecture-capture software, including: 1) decreased student attendance in class because they feel they can watch class later at a time of their own choosing, 2) additional time spent by the instructor dealing with the technology, and 3) problems with hardware or software during class time that prevents recording a given day's lecture. These problems can often be addressed or justified relatively easily. If problem 1 is of concern to an instructor it can be addressed by blocking online access to individual students who have a poor record of class attendance. In the case of problem 2, the extra time spent with the technology is often offset by a reduction in time answering questions from students who have missed class. Problem 3 does happen, but in the author's experience it is fairly rare, representing less than 5% of class sessions per semester. Student comments have been overwhelmingly favorable towards the use of captured lectures since the technology was first adopted in the author's classes in 2009.

  13. A Class of High-Resolution Explicit and Implicit Shock-Capturing Methods

    NASA Technical Reports Server (NTRS)

    Yee, H. C.

    1994-01-01

    The development of shock-capturing finite difference methods for hyperbolic conservation laws has been a rapidly growing area for the last decade. Many of the fundamental concepts, state-of-the-art developments and applications to fluid dynamics problems can only be found in meeting proceedings, scientific journals and internal reports. This paper attempts to give a unified and generalized formulation of a class of high-resolution, explicit and implicit shock capturing methods, and to illustrate their versatility in various steady and unsteady complex shock waves, perfect gases, equilibrium real gases and nonequilibrium flow computations. These numerical methods are formulated for the purpose of ease and efficient implementation into a practical computer code. The various constructions of high-resolution shock-capturing methods fall nicely into the present framework and a computer code can be implemented with the various methods as separate modules. Included is a systematic overview of the basic design principle of the various related numerical methods. Special emphasis will be on the construction of the basic nonlinear, spatially second and third-order schemes for nonlinear scalar hyperbolic conservation laws and the methods of extending these nonlinear scalar schemes to nonlinear systems via the approximate Riemann solvers and flux-vector splitting approaches. Generalization of these methods to efficiently include real gases and large systems of nonequilibrium flows will be discussed. Some perbolic conservation laws to problems containing stiff source terms and terms and shock waves are also included. The performance of some of these schemes is illustrated by numerical examples for one-, two- and three-dimensional gas-dynamics problems. The use of the Lax-Friedrichs numerical flux to obtain high-resolution shock-capturing schemes is generalized. This method can be extended to nonlinear systems of equations without the use of Riemann solvers or flux-vector splitting approaches and thus provides a large savings for multidimensional, equilibrium real gases and nonequilibrium flow computations.

  14. Gd@C82 metallofullerenes for neutron capture therapy—fullerene solubilization by poly(ethylene glycol)-block-poly(2-(N, N-diethylamino)ethyl methacrylate) and resultant efficacy in vitro

    PubMed Central

    Horiguchi, Yukichi; Kudo, Shinpei; Nagasaki, Yukio

    2011-01-01

    Poly(ethylene glycol)-block-poly(2-(N,N-diethylamino)ethyl methacrylate) (PEG-b-PAMA) was found to solubilize fullerenes such as C60, and this technique was applied to metallofullerenes. Gd@C82 was easily dissolved in water in the presence of PEG-b-PAMA without any covalent derivatization, forming a transparent complex about 20–30 nm in diameter. Low cytotoxicity was confirmed in vitro. Neutron irradiation of cultured cells (colon-26 adenocarcinoma) with Gd@C82-PEG-b-PAMA-complexed nanoparticles showed effective cytotoxicity, indicating the effective emission of gamma rays and internal conversion electrons produced from the neutron capture reaction of Gd. This result suggests a potentially valuable approach to gadolinium-based neutron capture therapy. PMID:27877415

  15. Effectiveness of Parent-Child Interaction Therapy (PCIT) among Chinese Families

    ERIC Educational Resources Information Center

    Leung, Cynthia; Tsang, Sandra; Heung, Kitty; Yiu, Ivan

    2009-01-01

    Objective: This study examined the effectiveness of Parent-Child Interaction Therapy (PCIT) among Chinese parents and children in Hong Kong with significant behavior problems. Method: The participants (intervention group, 48; comparison group, 62) completed questionnaires on child behavior problems and parenting stress before and after…

  16. Problems and solutions for patients with fibromyalgia: Building new helping relationships.

    PubMed

    Montesó-Curto, Pilar; García-Martinez, Montserrat; Romaguera, Sara; Mateu, María Luisa; Cubí-Guillén, María Teresa; Sarrió-Colas, Lidia; Llàdser, Anna Núria; Bradley, Stephen; Panisello-Chavarria, María Luisa

    2018-02-01

    The aim of this study was to identify the main biological, psychological and sociological problems and potential solutions for patients diagnosed with fibromyalgia by use of Group Problem-Solving Therapy. Group Problem-Solving Therapy is a technique for identifying and solving problems, increasing assertiveness, self-esteem and eliminating negative thoughts. Qualitative phenomenological interpretive design: Group Problem-Solving Therapy sessions conducted with patients suffering fibromyalgia were studied; participants recruited via the Rheumatology Department at a general hospital and associations in Catalonia, Spain with sessions conducted in nearby university setting. The study included 44 people diagnosed with fibromyalgia (43 female, 1 male) from 6 Group Problem-Solving Therapy sessions. Data collected from March-June 2013. A total of 24 sessions were audio recorded, all with prior informed consent. Data were transcribed and then analysed in accordance with established methods of inductive thematic analysis, via a process of reduction to manage and classify data. Five themes were identified: (1) Current problems are often related to historical trauma; (2) There are no "one size fits all" solutions; (3) Fibromyalgia is life-changing; (4) Fibromyalgia is widely misunderstood; (5) Statistically Significant impacts on physical, psychological and social are described. The majority of patients' problems were associated with their previous history and the onset of fibromyalgia; which may be related to trauma in adolescence, early adulthood or later. The solutions provided during the groups appeared to be accepted by the participants. These findings can improve the self-management of fibromyalgia patients by helping to enhance adaptive behaviours and incorporating the female gender approach. © 2017 John Wiley & Sons Ltd.

  17. Problems associated with pooling mark-recapture data prior to estimating stopover length for migratory passerines

    Treesearch

    Sara R. Morris; Erica M. Turner; David A. Liebner; Amanda M. Larracuente; H. David Sheets

    2005-01-01

    One measure of the importance of a stopover site is the length of time that migrants spend at an area, however measuring the time birds spend at a stopover site has proven difficult. Most banding studies have presented only minimum length of stopover, based on the difference between initial capture and final recapture of birds that are captured more than once. Cormack-...

  18. Model-Based Systems Engineering for Capturing Mission Architecture System Processes with an Application Case Study - Orion Flight Test 1

    NASA Technical Reports Server (NTRS)

    Bonanne, Kevin H.

    2011-01-01

    Model-based Systems Engineering (MBSE) is an emerging methodology that can be leveraged to enhance many system development processes. MBSE allows for the centralization of an architecture description that would otherwise be stored in various locations and formats, thus simplifying communication among the project stakeholders, inducing commonality in representation, and expediting report generation. This paper outlines the MBSE approach taken to capture the processes of two different, but related, architectures by employing the Systems Modeling Language (SysML) as a standard for architecture description and the modeling tool MagicDraw. The overarching goal of this study was to demonstrate the effectiveness of MBSE as a means of capturing and designing a mission systems architecture. The first portion of the project focused on capturing the necessary system engineering activities that occur when designing, developing, and deploying a mission systems architecture for a space mission. The second part applies activities from the first to an application problem - the system engineering of the Orion Flight Test 1 (OFT-1) End-to-End Information System (EEIS). By modeling the activities required to create a space mission architecture and then implementing those activities in an application problem, the utility of MBSE as an approach to systems engineering can be demonstrated.

  19. [Advances in the research of effects of music therapy on pain and anxiety in burn patients].

    PubMed

    Jinyi, Li; Yungui, Wang

    2015-06-01

    Pain and anxiety engender major psychic problems during all phases of treatment for burn patients. Analgesic alone does not allay these problems satisfactorily in these patients. Music therapy, as an important complementary and alternative therapy, has been widely used in multiple medical fields. However, its positive effect on alleviation of pain and anxiety in burn patients is undefined. The objective of this review is to summarize the feasibility, application fields, methods, and the effectiveness of music therapy in allaying pain and anxiety of burn patients during the whole course of treatment.

  20. Free terminal time optimal control problem of an HIV model based on a conjugate gradient method.

    PubMed

    Jang, Taesoo; Kwon, Hee-Dae; Lee, Jeehyun

    2011-10-01

    The minimum duration of treatment periods and the optimal multidrug therapy for human immunodeficiency virus (HIV) type 1 infection are considered. We formulate an optimal tracking problem, attempting to drive the states of the model to a "healthy" steady state in which the viral load is low and the immune response is strong. We study an optimal time frame as well as HIV therapeutic strategies by analyzing the free terminal time optimal tracking control problem. The minimum duration of treatment periods and the optimal multidrug therapy are found by solving the corresponding optimality systems with the additional transversality condition for the terminal time. We demonstrate by numerical simulations that the optimal dynamic multidrug therapy can lead to the long-term control of HIV by the strong immune response after discontinuation of therapy.

  1. Carboranylporphyrins and uses thereof

    DOEpatents

    Wu, Haitao; Miura, Michiko

    2006-02-07

    The present invention is directed to low toxicity boronated compounds and methods for their use in the treatment, visualization, and diagnosis of tumors. More specifically, the present invention is directed to low toxicity carborane-containing 5, 10, 15, 20-tetraphenylporphyrin compounds and methods for their use particularly in boron neutron capture therapy (BNCT) and photodynamic therapy (PDT) for the treatment of tumors of the brain, head and neck, and surrounding tissue. The invention is also directed to using these carborane-containing tetraphenyl porphyrin compounds to methods of tumor imaging and/or diagnosis such as MRI, SPECT, or PET.

  2. Carboranylporphyrins and uses thereof

    DOEpatents

    Wu, Haitao; Miura, Michiko

    2006-01-24

    The present invention is directed to low toxicity boronated compounds and methods for their use in the treatment, visualization, and diagnosis of tumors. More specifically, the present invention is directed to low toxicity carborane-containing 5, 10, 15, 20-tetraphenylporphyrin compounds and methods for their use particularly in boron neutron capture therapy (BNCT) and photodynamic therapy (PDT) for the treatment of tumors of the brain, head, neck, and surrounding tissue. The invention is also directed to using these carborane-containing tetraphenyl porphyrin compounds to methods of tumor imaging and/or diagnosis such as MRI, SPECT, or PET.

  3. A preliminary, qualitative exploration of the influences associated with drop-out from cognitive-behavioural therapy for problem gambling: an Australian perspective.

    PubMed

    Dunn, Kirsten; Delfabbro, Paul; Harvey, Peter

    2012-06-01

    It has been estimated that 80% of Australians engage in some form of gambling, with approximately 115,000 Australians experiencing severe problems (Productivity Commission 2010). Very few people with problem gambling seek help and, of those who do, large numbers drop-out of therapy before completing their program. To gain insights into these problems, participants who had either completed or withdrawn prematurely from an individual CBT-based problem gambling treatment program were interviewed to examine factors predictive of premature withdrawal from therapy as well as people's 'readiness' for change. The results indicated that there might be some early indicators of risk for early withdrawal. These included: gambling for pleasure or social interaction; non-compliance with homework tasks; gambling as a strategy to avoid personal issues or dysphoric mood; high levels of guilt and shame; and a lack of readiness for change. The study further showed that application of the term 'drop-out' to some clients may be an unnecessarily negative label in that a number appear to have been able to reduce their gambling urges even after a short exposure to therapy.

  4. Massive digoxin ingestion. Report of a case and review of currently available therapies.

    PubMed Central

    Bremner, W F; Third, J L; Lawrie, T D

    1977-01-01

    Recent reports of treatment of massive digoxin overdosage have emphasized the success of medical therapy. This report describes a fatal outcome to this problem despite aggressive medical management, including pervenous cardiac pacing and draws attention to deficiencies in current treatment of a serious problem. PMID:328024

  5. Problem-Solving Therapy for Depression in Adults: A Systematic Review

    ERIC Educational Resources Information Center

    Gellis, Zvi D.; Kenaley, Bonnie

    2008-01-01

    Objectives: This article presents a systematic review of the evidence on problem-solving therapy (PST) for depressive disorders in noninstitutionalized adults. Method: Intervention studies using randomized controlled designs are included and methodological quality is assessed using a standard set of criteria from the Cochrane Collaborative Review…

  6. The Doctor's and the Patient's Problems in Treating Obesity

    PubMed Central

    Keegan, D. L.

    1977-01-01

    The major difficulties for physicians and patients alike in the management of obesity are lack of goals, poor understanding of their roles in diet therapy and often a negative, helpless attitude toward therapy itself. Physicians clearly have a key role as coordinators of a weight reduction program, through their skills in assessing overweight problems. In addition, the physician plays an important role in education, communication, motivation and organization of the weight reduction therapy. PMID:21304867

  7. INEL BNCT Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ackermann, A.L.

    1991-08-01

    This Bulletin presents a summary of accomplishments and highlights in the Idaho National Engineering Laboratory's (INEL) Boron Neutron Capture Therapy (BNCT) Program for August 1991. This bulletin includes information on the brain tumor and melanoma research programs, Power Burst Facility (PBF) technical support and modifications, PBF operations, and updates to the animal data charts.

  8. An algorithm for verifying biventricular capture based on evoked-response morphology.

    PubMed

    Diotallevi, Paolo; Ravazzi, Pier Antonio; Gostoli, Enrico; De Marchi, Giuseppe; Militello, Carmelo; Kraetschmer, Hannes

    2005-01-01

    Cardiac resynchronization therapy relies on consistent beat-by-beat myocardial capture in both ventricles. A pacemaker ensuring right (RV) and left ventricular (LV) capture through reliable capture verification and automatic output adjustment would contribute to patients' safety and quality of life. We studied the feasibility of an algorithm based on evoked-response (ER) morphology for capture verification in both the ventricles. RV and LV ER signals were recorded in 20 patients (mean age 72.5 years, range 64.3-80.4 years, 4 females and 16 males) during implantation of biventricular (BiV) pacing systems. Leads of several manufacturers were tested. Pacing and intracardiac electrogram (IEGM) recording were performed using an external pulse generator. IEGM and surface-lead electrocardiogram (ECG) signals were recorded under different pacing conditions for 10 seconds each: RV pacing only, LV pacing only, and BiV pacing with several interventricular delays. Based on morphology characteristics, ERs were classified manually for capture and failure to capture, and the validity of the classification was assessed by reference to the ECG. A total of 3,401 LV- and 3,345 RV-paced events were examined. In the RV and LV, the sensitivities of the algorithm were 95.6% and 96.1% in the RV and LV, respectively, and the corresponding specificities were 91.4% and 95.2%, respectively. The lower sensitivity in the RV was attributed to signal blanking in both channels during BiV pacing with a nonzero interventricular delay. The analysis revealed that the algorithm for identifying capture and failure to capture based on the ER-signal morphology was safe and effective in each ventricle with all leads tested in the study.

  9. Anodal right ventricular capture during left ventricular stimulation in CRT-implantable cardioverter defibrillators.

    PubMed

    Thibault, Bernard; Roy, Denis; Guerra, Peter G; Macle, Laurent; Dubuc, Marc; Gagné, Pierre; Greiss, Isabelle; Novak, Paul; Furlani, Aldo; Talajic, Mario

    2005-07-01

    Cardiac resynchronization therapy (CRT) has been shown to improve symptoms of patients with moderate to severe heart failure. Optimal CRT involves biventricular or left ventricular (LV) stimulation alone, atrio-ventricular (AV) delay optimization, and possibly interventricular timing adjustment. Recently, anodal capture of the right ventricle (RV) has been described for patients with CRT-pacemakers. It is unknown whether the same phenomenon exists in CRT systems associated with defibrillators (CRT-ICD). The RV leads used in these systems are different from pacemaker leads: they have a larger diameter and shocking coils, which may affect the occurrence of anodal capture. We looked for anodal RV capture during LV stimulation in 11 consecutive patients who received a CRT-ICD system with RV leads with a true bipolar design. Fifteen patients who had RV leads with an integrated design were used as controls. Anodal RV and LV thresholds were determined at pulse width (pw) durations of 0.2, 0.5, and 1.0 ms. RV anodal capture during LV pacing was found in 11/11 patients at some output with true bipolar RV leads versus 0/15 patients with RV leads with an integrated bipolar design. Anodal RV capture threshold was more affected by changes in pw duration than LV capture threshold. In CRT-ICD systems, RV leads with a true bipolar design with the proximal ring also used as the anode for LV pacing are associated with a high incidence of anodal RV capture during LV pacing. This may affect the clinical response to alternative resynchronization methods using single LV stimulation or interventricular delay programming.

  10. Electrolyte imbalance and sleep problems during anti-retroviral therapy: an under-recognized problem.

    PubMed

    Manzar, Md Dilshad; Sony, Peter; Salahuddin, Mohammed; Kumalo, Abera; Geneto, Mathewos; Pandi-Perumal, Seithikurippu R; Moscovitch, Adam; BaHammam, Ahmed S

    2017-01-01

    Human immunodeficiency virus (HIV) infection, and the anti-retroviral therapy (ART) associated complications necessitate that the medical care system keeps evolving for proper management of this group of patients. Electrolyte imbalance and sleep problems are common in patients on ART. Both of these conditions are associated with increased morbidity (such as acute kidney injury, chronic kidney disease, low CD4 count, non-adherence and depression) and mortality. Therefore, screening for both sleep problems and electrolytes imbalance may help to decrease the risk of complications in patients on ART.

  11. Electrolyte imbalance and sleep problems during anti-retroviral therapy: an under-recognized problem

    PubMed Central

    Manzar, Md Dilshad; Sony, Peter; Salahuddin, Mohammed; Kumalo, Abera; Geneto, Mathewos; Pandi-Perumal, Seithikurippu R; Moscovitch, Adam; BaHammam, Ahmed S

    2017-01-01

    Human immunodeficiency virus (HIV) infection, and the anti-retroviral therapy (ART) associated complications necessitate that the medical care system keeps evolving for proper management of this group of patients. Electrolyte imbalance and sleep problems are common in patients on ART. Both of these conditions are associated with increased morbidity (such as acute kidney injury, chronic kidney disease, low CD4 count, non-adherence and depression) and mortality. Therefore, screening for both sleep problems and electrolytes imbalance may help to decrease the risk of complications in patients on ART. PMID:28966741

  12. Assessing Health-Related Quality of Life with Antimicrobial Photodynamic Therapy (APDT) and Low Level Laser Therapy (LLLT) after Third Molar Removal.

    PubMed

    Batinjan, Goran; Filipović Zore, Irina; Rupić, Ivana; Bago Jurič, Ivona; Zore, Zvonimir; Gabrić Pandurić, Dragana

    2013-01-01

    The purpose of this study was to evaluate the antimicrobial photodynamic therapy (APDT) and low level laser therapy (LLLT) on wound healing, pain intensity, swelling problems, halitosis and the postoperative usage of analgesics after surgical removal of lower third molars. One hundred and fifty patients, randomly divided into three groups were selected (50 per each group). The P1 group received the APDT after a third molar surgery, the P2 group received the LLLT and the C group (control group) was without any additional therapy after surgery. A photoactive substance was applied in the APDT study group before suturing. After 60 seconds the photosensitive substance was thoroughly washed with saline water and the laser light was applied in two intervals (30 seconds each). The irradiation power was 50 mW while the wavelength was 660 nm. The laser therapy in P2 group was performed before suturing and the laser light was applied also in two intervals (90 seconds each), the irradiation power was 90 mW while the wavelength was the same as in the first group - 660 nm. Postoperative follow-ups were scheduled on the third and the seventh day in patients who received laser therapy. The results of the postoperative evaluation showed that there was a statistically significant difference in the postoperative wound healing, pain intensity, swelling problems, halitosis and analgesics intake between patients in all three groups (p<0.001). The patients that were subjected to APDT (P1) had the least postoperative problems. After the laser therapy (P1 and P2) wound healing was without any complications, opposite from the patients from the C group (p<0.001). Postoperative application of a laser therapy significantly reduced patient's use of analgesics over the observed period of time (p<0.001). Both modalities of laser therapy significantly reduced postoperative problems after surgical removal of third lower molars with the best results in both laser groups.

  13. Assessment of a targeted resequencing assay as a support tool in the diagnosis of lysosomal storage disorders

    PubMed Central

    2014-01-01

    Background With over 50 different disorders and a combined incidence of up to 1/3000 births, lysosomal storage diseases (LSDs) constitute a major public health problem and place an enormous burden on affected individuals and their families. Many factors make LSD diagnosis difficult, including phenotype and penetrance variability, shared signs and symptoms, and problems inherent to biochemical diagnosis. Developing a powerful diagnostic tool could mitigate the protracted diagnostic process for these families, lead to better outcomes for current and proposed therapies, and provide the basis for more appropriate genetic counseling. Methods We have designed a targeted resequencing assay for the simultaneous testing of 57 lysosomal genes, using in-solution capture as the enrichment method and two different sequencing platforms. A total of 84 patients with high to moderate-or low suspicion index for LSD were enrolled in different centers in Spain and Portugal, including 18 positive controls. Results We correctly diagnosed 18 positive blinded controls, provided genetic diagnosis to 25 potential LSD patients, and ended with 18 diagnostic odysseys. Conclusion We report the assessment of a next–generation-sequencing-based approach as an accessory tool in the diagnosis of LSDs, a group of disorders which have overlapping clinical profiles and genetic heterogeneity. We have also identified and quantified the strengths and limitations of next generation sequencing (NGS) technology applied to diagnosis. PMID:24767253

  14. Capturing Students' Abstraction While Solving Organic Reaction Mechanism Problems across a Semester

    ERIC Educational Resources Information Center

    Weinrich, M. L.; Sevian, H.

    2017-01-01

    Students often struggle with solving mechanism problems in organic chemistry courses. They frequently focus on surface features, have difficulty attributing meaning to symbols, and do not recognize tasks that are different from the exact tasks practiced. To be more successful, students need to be able to extract salient features, map similarities…

  15. Seeing Mathematics through a New Lens: Using Photos in the Mathematics Classroom

    ERIC Educational Resources Information Center

    Bragg, Leicha A.; Nicol, Cynthia

    2011-01-01

    In this article, the authors present an approach to developing open-ended problems through capturing contextualised mathematics in photographs. They draw upon their research with the Problem Posing Research Project, a collaborative venture between an Australian and a Canadian university to broaden pre-service teachers pedagogical practices in the…

  16. Latent Class Analysis of Conduct Problems of Elementary Students Receiving Special Education Services

    ERIC Educational Resources Information Center

    Toupin, Jean; Déry, Michèle; Verlaan, Pierrette; Lemelin, Jean-Pascal; Lecocq, Aurélie; Jagiellowicz, Jadwiga

    2016-01-01

    Students with conduct problems (CPs) may present heterogeneity in terms of behavioral manifestations and service needs. Previous studies using Latent Class Analysis (LCA) to capture this heterogeneity have been conducted mostly with community samples and have often applied a narrow definition of CP. Considering this context, this study…

  17. A new shock-capturing numerical scheme for ideal hydrodynamics

    NASA Astrophysics Data System (ADS)

    Fecková, Z.; Tomášik, B.

    2015-05-01

    We present a new algorithm for solving ideal relativistic hydrodynamics based on Godunov method with an exact solution of Riemann problem for an arbitrary equation of state. Standard numerical tests are executed, such as the sound wave propagation and the shock tube problem. Low numerical viscosity and high precision are attained with proper discretization.

  18. Correction of Line Interleaving Displacement in Frame Captured Aerial Video Imagery

    Treesearch

    B. Cooke; A. Saucier

    1995-01-01

    Scientists with the USDA Forest Service are currently assessing the usefulness of aerial video imagery for various purposes including midcycle inventory updates. The potential of video image data for these purposes may be compromised by scan line interleaving displacement problems. Interleaving displacement problems cause features in video raster datasets to have...

  19. Skin damage associated with intravenous therapy: common problems and strategies for prevention.

    PubMed

    Thayer, Debra

    2012-01-01

    Infusion therapy is among the most common health care interventions, with approximately 90% of hospitalized patients receiving vascular access and an estimated 1.3 million home infusion therapies delivered annually. Whereas most individuals complete their therapy uneventfully, others experience alterations in skin integrity, some significant enough to disrupt therapy. There are limited published data on the incidence of skin damage associated with infusion therapy, and the etiology of damage has not been previously described in detail. Wound, ostomy, and continence (WOC) nurses have developed a significant understanding of skin-related problems and effective prevention strategies from over 40 years of experience with ostomy patients--another population in which adhesive wear is a constant and localized, superficial skin damage is common. This article will offer a WOC nursing perspective of skin damage and seek to provide a context for understanding and preventing skin damage in the infusion therapy patient.

  20. Sampling design considerations for demographic studies: a case of colonial seabirds

    USGS Publications Warehouse

    Kendall, William L.; Converse, Sarah J.; Doherty, Paul F.; Naughton, Maura B.; Anders, Angela; Hines, James E.; Flint, Elizabeth

    2009-01-01

    For the purposes of making many informed conservation decisions, the main goal for data collection is to assess population status and allow prediction of the consequences of candidate management actions. Reducing the bias and variance of estimates of population parameters reduces uncertainty in population status and projections, thereby reducing the overall uncertainty under which a population manager must make a decision. In capture-recapture studies, imperfect detection of individuals, unobservable life-history states, local movement outside study areas, and tag loss can cause bias or precision problems with estimates of population parameters. Furthermore, excessive disturbance to individuals during capture?recapture sampling may be of concern because disturbance may have demographic consequences. We address these problems using as an example a monitoring program for Black-footed Albatross (Phoebastria nigripes) and Laysan Albatross (Phoebastria immutabilis) nesting populations in the northwestern Hawaiian Islands. To mitigate these estimation problems, we describe a synergistic combination of sampling design and modeling approaches. Solutions include multiple capture periods per season and multistate, robust design statistical models, dead recoveries and incidental observations, telemetry and data loggers, buffer areas around study plots to neutralize the effect of local movements outside study plots, and double banding and statistical models that account for band loss. We also present a variation on the robust capture?recapture design and a corresponding statistical model that minimizes disturbance to individuals. For the albatross case study, this less invasive robust design was more time efficient and, when used in combination with a traditional robust design, reduced the standard error of detection probability by 14% with only two hours of additional effort in the field. These field techniques and associated modeling approaches are applicable to studies of most taxa being marked and in some cases have individually been applied to studies of birds, fish, herpetofauna, and mammals.

  1. Designing capture trajectories to unstable periodic orbits around Europa

    NASA Technical Reports Server (NTRS)

    Russell, Ryan P.; Lam, Try

    2006-01-01

    The hostile environment of third body perturbations restricts a mission designer's ability to find well-behaved reproducible capture trajectories when dealing with limited control authority as is typical with low-thrust missions. The approach outlined in this paper confronts this shortcoming by utilizing dynamical systems theory and an extensive preexisting database of Restricted Three Body Problem (RTBP) periodic orbits. The stable manifolds of unstable periodic orbits are utilized to attract a spacecraft towards Europa. By selecting an appropriate periodic orbit, a mission designer can control important characteristics of the captured state including stability, minimum altitudes, characteristic inclinations, and characteristic radii among others. Several free parameters are optimized in the non-trivial mapping from the RTBP to a more realistic model. Although the ephemeris capture orbit is ballistic by design, low-thrust is used to target the state that leads to the capture orbit, control the spacecraft after arriving on the unstable quasi-periodic orbit, and begin the spiral down towards the science orbit. The approach allows a mission designer to directly target fuel efficient captures at Europa in an ephemeris model. Furthermore, it provides structure and controllability to the design of capture trajectories that reside in a chaotic environment.

  2. The multidisciplinary treatment plan: a format for enhancing activity therapy department involvement.

    PubMed

    Lang, E; Mattson, M

    1985-01-01

    A structured, goal-oriented format for enhancing the involvement of activity therapy disciplines in the multidisciplinary treatment planning process has been developed in a large private psychiatric teaching hospital. The format, an adaptation of the problem-oriented record, encompasses formal procedures for identifying and recording relevant problems, goals, methods, and objectives for activity therapy treatment. The benefits of this approach include the development of specific, measurable, attainable functional goals; increased accountability in treatment planning and delivery; less time spent in documentation; and education of other staff about the role and function of activities therapy. Patients have a better understanding of their goals and the steps needed to achieve them and show increased participation in the therapy process.

  3. Effectiveness of a Web-based Intervention for Problem Drinkers and Reasons for Dropout: Randomized Controlled Trial

    PubMed Central

    de Haan, Hein A; ter Huurne, Elke D; Becker, Eni S; de Jong, Cor AJ

    2010-01-01

    Background Online self-help interventions for problem drinkers show promising results, but the effectiveness of online therapy with active involvement of a therapist via the Internet only has not been examined. Objective The objective of our study was to evaluate an e-therapy program with active therapeutic involvement for problem drinkers, with the hypotheses that e-therapy would (1) reduce weekly alcohol consumption, and (2) improve health status. Reasons for dropout were also systematically investigated. Method In an open randomized controlled trial, Dutch-speaking problem drinkers in the general population were randomly assigned (in blocks of 8, according to a computer-generated random list) to the 3-month e-therapy program (n = 78) or the waiting list control group (n = 78). The e-therapy program consisted of a structured 2-part online treatment program in which the participant and the therapist communicated asynchronously, via the Internet only. Participants in the waiting list control group received “no-reply” email messages once every 2 weeks. The primary outcome measures were (1) the difference in the score on weekly alcohol consumption, and (2) the proportion of participants drinking under the problem drinking limit. Intention-to-treat analyses were performed using multiple imputations to deal with loss to follow-up. A dropout questionnaire was sent to anyone who did not complete the 3-month assessment. Reasons for dropout were independently assessed by the first and third author. Results Of the 156 individuals who were randomly assigned, 102 (65%) completed assessment at 3 months. In the intention-to-treat analyses, the e-therapy group (n = 78) showed a significantly greater decrease in alcohol consumption than those in the control group (n = 78) at 3 months. The e-therapy group decreased their mean weekly alcohol consumption by 28.8 units compared with 3.1 units in the control group, a difference in means of 25.6 units on a weekly basis (95% confidence interval 15.69-35.80, P < .001). The between-group effect size (pooled SD) was large (d = 1.21). The results also showed that 68% (53/78) of the e-therapy group was drinking less than 15 (females) or 22 (males) units a week, compared with 15% (12/78) in the control group (OR 12.0, number needed to treat 1.9, P < .001). Dropout analysis showed that the main reasons for dropouts (n = 54) were personal reasons unrelated to the e-therapy program, discomfort with the treatment protocol, and satisfaction with the positive results achieved. Conclusions E-therapy for problem drinking is an effective intervention that can be delivered to a large population who otherwise do not seek help for their drinking problem. Insight into reasons for dropout can help improve e-therapy programs to decrease the number of dropouts. Additional research is needed to directly compare the effectiveness of the e-therapy program with a face-to-face treatment program. Trial registration ISRCTN39104853; http://controlled-trials.com/ISRCTN39104853/ISRCTN39104853 (Archived by WebCite at http://www.webcitation.org/5uX1R5xfW) PMID:21163776

  4. A mixed-methods evaluation of complementary therapy services in palliative care: yoga and dance therapy.

    PubMed

    Selman, L E; Williams, J; Simms, V

    2012-01-01

    To inform service provision and future research, we evaluated two complementary therapy services: yoga classes and dance therapy [The Lebed Method (TLM)]. Both were run as 6-week group courses. Patients completed the Measure Yourself Concerns and Wellbeing questionnaire pre- and post-course. Mean change over time was calculated for patient-nominated concern and well-being scores. Qualitative data regarding factors affecting health other than the therapy and benefits of the service were analysed using content analysis. Eighteen patients participated (mean age 63.8 years; 16 female; 14 cancer diagnoses); 10 were doing yoga, five TLM, and three both yoga and TLM; 14 completed more than one assessed course. Patients' most prevalent concerns were: mobility/fitness (n= 20), breathing problems (n= 20), arm, shoulder and neck problems (n= 18), difficulty relaxing (n= 8), back/postural problems (n= 8), fear/anxiety (n= 5). Factors affecting patients' health other than the therapy were prevalent and predominantly negative (e.g. treatment side effects). Patients reported psycho-spiritual, physical and social benefits. Concern scores improved significantly (P < 0.001) for both therapies; improved well-being was clinically significant for yoga. Evaluations of group complementary therapy services are feasible, can be conducted effectively and have implications for future research. Yoga and TLM may be of benefit in this population. © 2011 Blackwell Publishing Ltd.

  5. Predicting the performance uncertainty of a 1-MW pilot-scale carbon capture system after hierarchical laboratory-scale calibration and validation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Zhijie; Lai, Canhai; Marcy, Peter William

    2017-05-01

    A challenging problem in designing pilot-scale carbon capture systems is to predict, with uncertainty, the adsorber performance and capture efficiency under various operating conditions where no direct experimental data exist. Motivated by this challenge, we previously proposed a hierarchical framework in which relevant parameters of physical models were sequentially calibrated from different laboratory-scale carbon capture unit (C2U) experiments. Specifically, three models of increasing complexity were identified based on the fundamental physical and chemical processes of the sorbent-based carbon capture technology. Results from the corresponding laboratory experiments were used to statistically calibrate the physical model parameters while quantifying some of theirmore » inherent uncertainty. The parameter distributions obtained from laboratory-scale C2U calibration runs are used in this study to facilitate prediction at a larger scale where no corresponding experimental results are available. In this paper, we first describe the multiphase reactive flow model for a sorbent-based 1-MW carbon capture system then analyze results from an ensemble of simulations with the upscaled model. The simulation results are used to quantify uncertainty regarding the design’s predicted efficiency in carbon capture. In particular, we determine the minimum gas flow rate necessary to achieve 90% capture efficiency with 95% confidence.« less

  6. Laser Capture Microdissection in the Genomic and Proteomic Era: Targeting the Genetic Basis of Cancer

    PubMed Central

    Domazet, Barbara; MacLennan, Gregory T.; Lopez-Beltran, Antonio; Montironi, Rodolfo; Cheng, Liang

    2008-01-01

    The advent of new technologies has enabled deeper insight into processes atsubcellular levels, which will ultimately improve diagnostic procedures and patient outcome. Thanks to cell enrichment methods, it is now possible to study cells in their native environment. This has greatly contributed to a rapid growth in several areas, such as gene expression analysis, proteomics, and metabolonomics. Laser capture microdissection (LCM) as a method of procuring subpopulations of cells under direct visual inspection is playing an important role in these areas. This review provides an overview of existing LCM technology and its downstream applications in genomics, proteomics, diagnostics and therapy. PMID:18787684

  7. Laser capture microdissection in the genomic and proteomic era: targeting the genetic basis of cancer.

    PubMed

    Domazet, Barbara; Maclennan, Gregory T; Lopez-Beltran, Antonio; Montironi, Rodolfo; Cheng, Liang

    2008-03-15

    The advent of new technologies has enabled deeper insight into processes at subcellular levels, which will ultimately improve diagnostic procedures and patient outcome. Thanks to cell enrichment methods, it is now possible to study cells in their native environment. This has greatly contributed to a rapid growth in several areas, such as gene expression analysis, proteomics, and metabolonomics. Laser capture microdissection (LCM) as a method of procuring subpopulations of cells under direct visual inspection is playing an important role in these areas. This review provides an overview of existing LCM technology and its downstream applications in genomics, proteomics, diagnostics and therapy.

  8. Sexual Functioning in Clinical Couples: Discriminant Validity of the Sexual Interaction System Scale.

    ERIC Educational Resources Information Center

    Woody, Jane D.; And Others

    1994-01-01

    Examines whether a new instrument for measuring couple functioning would differentiate couples in therapy for sexual dysfunction from couples in therapy for other problems. While the other-problems group had greater sexual satisfaction than the sex dysfunction group, the groups were similar in experiencing moderate marital distress. (JPS)

  9. Multisystemic Therapy for Child Non-Externalizing Psychological and Health Problems: A Preliminary Review

    ERIC Educational Resources Information Center

    Pane, Heather T.; White, Rachel S.; Nadorff, Michael R.; Grills-Taquechel, Amie; Stanley, Melinda A.

    2013-01-01

    Multisystemic therapy (MST) is effective for decreasing or preventing delinquency and other externalizing behaviors and increasing prosocial or adaptive behaviors. The purpose of this project was to review the literature examining the efficacy of MST for other child psychological and health problems reflecting non-externalizing behaviors,…

  10. Intimacy Is a Transdiagnostic Problem for Cognitive Behavior Therapy: Functional Analytical Psychotherapy Is a Solution

    ERIC Educational Resources Information Center

    Wetterneck, Chad T.; Hart, John M.

    2012-01-01

    Problems with intimacy and interpersonal issues are exhibited across most psychiatric disorders. However, most of the targets in Cognitive Behavioral Therapy are primarily intrapersonal in nature, with few directly involved in interpersonal functioning and effective intimacy. Functional Analytic Psychotherapy (FAP) provides a behavioral basis for…

  11. On the use of secondary capture-recapture samples to estimate temporary emigration and breeding proportions

    USGS Publications Warehouse

    Kendall, W.L.; Nichols, J.D.; North, P.M.; Nichols, J.D.

    1995-01-01

    The use of the Cormack- Jolly-Seber model under a standard sampling scheme of one sample per time period, when the Jolly-Seber assumption that all emigration is permanent does not hold, leads to the confounding of temporary emigration probabilities with capture probabilities. This biases the estimates of capture probability when temporary emigration is a completely random process, and both capture and survival probabilities when there is a temporary trap response in temporary emigration, or it is Markovian. The use of secondary capture samples over a shorter interval within each period, during which the population is assumed to be closed (Pollock's robust design), provides a second source of information on capture probabilities. This solves the confounding problem, and thus temporary emigration probabilities can be estimated. This process can be accomplished in an ad hoc fashion for completely random temporary emigration and to some extent in the temporary trap response case, but modelling the complete sampling process provides more flexibility and permits direct estimation of variances. For the case of Markovian temporary emigration, a full likelihood is required.

  12. VAP/VAT: video analytics platform and test bed for testing and deploying video analytics

    NASA Astrophysics Data System (ADS)

    Gorodnichy, Dmitry O.; Dubrofsky, Elan

    2010-04-01

    Deploying Video Analytics in operational environments is extremely challenging. This paper presents a methodological approach developed by the Video Surveillance and Biometrics Section (VSB) of the Science and Engineering Directorate (S&E) of the Canada Border Services Agency (CBSA) to resolve these problems. A three-phase approach to enable VA deployment within an operational agency is presented and the Video Analytics Platform and Testbed (VAP/VAT) developed by the VSB section is introduced. In addition to allowing the integration of third party and in-house built VA codes into an existing video surveillance infrastructure, VAP/VAT also allows the agency to conduct an unbiased performance evaluation of the cameras and VA software available on the market. VAP/VAT consists of two components: EventCapture, which serves to Automatically detect a "Visual Event", and EventBrowser, which serves to Display & Peruse of "Visual Details" captured at the "Visual Event". To deal with Open architecture as well as with Closed architecture cameras, two video-feed capture mechanisms have been developed within the EventCapture component: IPCamCapture and ScreenCapture.

  13. Characterisation of an accelerator-based neutron source for BNCT versus beam energy

    NASA Astrophysics Data System (ADS)

    Agosteo, S.; Curzio, G.; d'Errico, F.; Nath, R.; Tinti, R.

    2002-01-01

    Neutron capture in 10B produces energetic alpha particles that have a high linear energy transfer in tissue. This results in higher cell killing and a higher relative biological effectiveness compared to photons. Using suitably designed boron compounds which preferentially localize in cancerous cells instead of healthy tissues, boron neutron capture therapy (BNCT) has the potential of providing a higher tumor cure rate within minimal toxicity to normal tissues. This clinical approach requires a thermal neutron source, generally a nuclear reactor, with a fluence rate sufficient to deliver tumorcidal doses within a reasonable treatment time (minutes). Thermal neutrons do not penetrate deeply in tissue, therefore BNCT is limited to lesions which are either superficial or otherwise accessible. In this work, we investigate the feasibility of an accelerator-based thermal neutron source for the BNCT of skin melanomas. The source was designed via MCNP Monte Carlo simulations of the thermalization of a fast neutron beam, generated by 7 MeV deuterons impinging on a thick target of beryllium. The neutron field was characterized at several deuteron energies (3.0-6.5 MeV) in an experimental structure installed at the Van De Graaff accelerator of the Laboratori Nazionali di Legnaro, in Italy. Thermal and epithermal neutron fluences were measured with activation techniques and fast neutron spectra were determined with superheated drop detectors (SDD). These neutron spectrometry and dosimetry studies indicated that the fast neutron dose is unacceptably high in the current design. Modifications to the current design to overcome this problem are presented.

  14. Technology in Parkinson disease: Challenges and Opportunities

    PubMed Central

    Espay, Alberto J.; Bonato, Paolo; Nahab, Fatta; Maetzler, Walter; Dean, John M.; Klucken, Jochen; Eskofier, Bjoern M.; Merola, Aristide; Horak, Fay; Lang, Anthony E.; Reilmann, Ralf; Giuffrida, Joe; Nieuwboer, Alice; Horne, Malcolm; Little, Max A.; Litvan, Irene; Simuni, Tanya; Dorsey, E. Ray; Burack, Michelle A.; Kubota, Ken; Kamondi, Anita; Godinho, Catarina; Daneault, Jean-Francois; Mitsi, Georgia; Krinke, Lothar; Hausdorff, Jeffery M.; Bloem, Bastiaan R.; Papapetropoulos, Spyros

    2016-01-01

    The miniaturization, sophistication, proliferation, and accessibility of technologies are enabling the capturing of more and previously inaccessible phenomena in Parkinson disease (PD). However, more information has not translated into greater understanding of disease complexity to satisfy diagnostic and therapeutic needs. Challenges include non-compatible technology platforms, the need for wide-scale and long-term deployment of sensor technology (in particular among vulnerable elderly patients), and the gap between the “big data” acquired with sensitive measurement technologies and their limited clinical application. Major opportunities could be realized if new technologies are developed as part of open-source and/or open-hardware platforms enabling multi-channel data capture, sensitive to the broad range of motor and non-motor problems that characterize PD, and adaptable into self-adjusting, individualized treatment delivery systems. The International Parkinson and Movement Disorders Society Task Force on Technology is entrusted to convene engineers, clinicians, researchers, and patients to promote the development of integrated measurement and closed-loop therapeutic systems with high patient adherence that also serve to: 1) encourage the adoption of clinico-pathophysiologic phenotyping and early detection of critical disease milestones; 2) enhance tailoring of symptomatic therapy; 3) improve subgroup targeting of patients for future testing of disease modifying treatments; and 4) identify objective biomarkers to improve longitudinal tracking of impairments in clinical care and research. This article summarizes the work carried out by the Task Force toward identifying challenges and opportunities in the development of technologies with potential for improving the clinical management and quality of life of individuals with PD. PMID:27125836

  15. Rapid differentiation of rocky mountain spotted fever from chickenpox, measles, and enterovirus infections and bacterial meningitis by frequency-pulsed electron capture gas-liquid chromatographic analysis of sera.

    PubMed Central

    Brooks, J B; McDade, J E; Alley, C C

    1981-01-01

    Normal sera and sera from patients with Rocky Mountain spotted fever, chickenpox, enterovirus infections, measles, and Neisseria meningitidis infections were extracted with organic solvents under acidic and basic conditions and then derivatized with trichloroethanol or heptafluorobutyric anhydride-ethanol to form electron-capturing derivatives of organic acids, alcohols, and amines. The derivatives were analyzed by frequency-pulsed electron capture gas-liquid chromatography (FPEC-GLC). There were unique differences in the FPEC-GLC profiles of sera obtained from patients with these respective diseases. With Rocky Mountain spotted fever patients, typical profiles were detected as early as 1 day after onset of disease and before antibody could be detected in the serum. Rapid diagnosis of Rocky Mountain spotted fever by FPEC-GLC could permit early and effective therapy, thus preventing many deaths from this disease. PMID:7276147

  16. Deep magnetic capture of magnetically loaded cells for spatially targeted therapeutics.

    PubMed

    Huang, Zheyong; Pei, Ning; Wang, Yanyan; Xie, Xinxing; Sun, Aijun; Shen, Li; Zhang, Shuning; Liu, Xuebo; Zou, Yunzeng; Qian, Juying; Ge, Junbo

    2010-03-01

    Magnetic targeting has recently demonstrated potential in promoting magnetically loaded cell delivery to target lesion, but its application is limited by magnetic attenuation. For deep magnetic capture of cells for spatial targeting therapeutics, we designed a magnetic pole, in which the magnetic field density can be focused at a distance from the pole. As flowing through a tube served as a model of blood vessels, the magnetically loaded mesenchymal stem cells (MagMSCs) were highly enriched at the site distance from the magnetic pole. The cell capture efficiency was positively influenced by the magnetic flux density, and inversely influenced by the flow velocity, and well-fitted with the deductive value by theoretical considerations. It appeared to us that the spatially-focused property of the magnetic apparatus promises a new deep targeting strategy to promote homing and engraftment for cellular therapy. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  17. Prompt gamma and neutron detection in BNCT utilizing a CdTe detector.

    PubMed

    Winkler, Alexander; Koivunoro, Hanna; Reijonen, Vappu; Auterinen, Iiro; Savolainen, Sauli

    2015-12-01

    In this work, a novel sensor technology based on CdTe detectors was tested for prompt gamma and neutron detection using boronated targets in (epi)thermal neutron beam at FiR1 research reactor in Espoo, Finland. Dedicated neutron filter structures were omitted to enable simultaneous measurement of both gamma and neutron radiation at low reactor power (2.5 kW). Spectra were collected and analyzed in four different setups in order to study the feasibility of the detector to measure 478 keV prompt gamma photons released from the neutron capture reaction of boron-10. The detector proved to have the required sensitivity to detect and separate the signals from both boron neutron and cadmium neutron capture reactions, which makes it a promising candidate for monitoring the spatial and temporal development of in vivo boron distribution in boron neutron capture therapy. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Impaired Contingent Attentional Capture Predicts Reduced Working Memory Capacity in Schizophrenia

    PubMed Central

    Mayer, Jutta S.; Fukuda, Keisuke; Vogel, Edward K.; Park, Sohee

    2012-01-01

    Although impairments in working memory (WM) are well documented in schizophrenia, the specific factors that cause these deficits are poorly understood. In this study, we hypothesized that a heightened susceptibility to attentional capture at an early stage of visual processing would result in working memory encoding problems. 30 patients with schizophrenia and 28 demographically matched healthy participants were presented with a search array and asked to report the orientation of the target stimulus. In some of the trials, a flanker stimulus preceded the search array that either matched the color of the target (relevant-flanker capture) or appeared in a different color (irrelevant-flanker capture). Working memory capacity was determined in each individual using the visual change detection paradigm. Patients needed considerably more time to find the target in the no-flanker condition. After adjusting the individual exposure time, both groups showed equivalent capture costs in the irrelevant-flanker condition. However, in the relevant-flanker condition, capture costs were increased in patients compared to controls when the stimulus onset asynchrony between the flanker and the search array was high. Moreover, the increase in relevant capture costs correlated negatively with working memory capacity. This study demonstrates preserved stimulus-driven attentional capture but impaired contingent attentional capture associated with low working memory capacity in schizophrenia. These findings suggest a selective impairment of top-down attentional control in schizophrenia, which may impair working memory encoding. PMID:23152783

  19. Impaired contingent attentional capture predicts reduced working memory capacity in schizophrenia.

    PubMed

    Mayer, Jutta S; Fukuda, Keisuke; Vogel, Edward K; Park, Sohee

    2012-01-01

    Although impairments in working memory (WM) are well documented in schizophrenia, the specific factors that cause these deficits are poorly understood. In this study, we hypothesized that a heightened susceptibility to attentional capture at an early stage of visual processing would result in working memory encoding problems. 30 patients with schizophrenia and 28 demographically matched healthy participants were presented with a search array and asked to report the orientation of the target stimulus. In some of the trials, a flanker stimulus preceded the search array that either matched the color of the target (relevant-flanker capture) or appeared in a different color (irrelevant-flanker capture). Working memory capacity was determined in each individual using the visual change detection paradigm. Patients needed considerably more time to find the target in the no-flanker condition. After adjusting the individual exposure time, both groups showed equivalent capture costs in the irrelevant-flanker condition. However, in the relevant-flanker condition, capture costs were increased in patients compared to controls when the stimulus onset asynchrony between the flanker and the search array was high. Moreover, the increase in relevant capture costs correlated negatively with working memory capacity. This study demonstrates preserved stimulus-driven attentional capture but impaired contingent attentional capture associated with low working memory capacity in schizophrenia. These findings suggest a selective impairment of top-down attentional control in schizophrenia, which may impair working memory encoding.

  20. The effect of salutogenic treatment principles on coping with mental health problems A randomised controlled trial.

    PubMed

    Langeland, Eva; Riise, Trond; Hanestad, Berit R; Nortvedt, Monica W; Kristoffersen, Kjell; Wahl, Astrid K

    2006-08-01

    Although the theory of salutogenesis provides generic understanding of how coping may be created, this theoretical perspective has not been explored sufficiently within research among people suffering from mental health problems. The aim of this study is to investigate the effect of talk-therapy groups based on salutogenic treatment principles on coping with mental health problems. In an experimental design, the participants (residents in the community) were randomly allocated to a coping-enhancing experimental group (n=59) and a control group (n=47) receiving standard care. Coping was measured using the sense of coherence (SOC) questionnaire. Coping improved significantly in the experiment group (+6 points) compared with the control group (-2 points). The manageability component contributed most to this improvement. Talk-therapy groups based on salutogenic treatment principles improve coping among people with mental health problems. Talk-therapy groups based on salutogenic treatment principles may be helpful in increasing coping in the recovery process among people with mental health problems and seem to be applicable to people with various mental health problems.

  1. Quo vadis radiotherapy? Technological advances and the rising problems in cancer management.

    PubMed

    Allen, Barry J; Bezak, Eva; Marcu, Loredana G

    2013-01-01

    Despite the latest technological advances in radiotherapy, cancer control is still challenging for several tumour sites. The survival rates for the most deadly cancers, such as ovarian and pancreatic, have not changed over the last decades. The solution to the problem lies in the change of focus: from local treatment to systemic therapy. The aim of this paper is to present the current status as well as the gaps in radiotherapy and, at the same time, to look into potential solutions to improve cancer control and survival. The currently available advanced radiotherapy treatment techniques have been analysed and their cost-effectiveness discussed. The problem of systemic disease management was specifically targeted. Clinical studies show limited benefit in cancer control from hadron therapy. However, targeted therapies together with molecular imaging could improve treatment outcome for several tumour sites while controlling the systemic disease. The advances in photon therapy continue to be competitive with the much more expensive hadron therapy. To justify the cost effectiveness of proton/heavy ion therapy, there is a need for phase III randomised clinical trials. Furthermore, the success of systemic disease management lies in the fusion between radiation oncology technology and microbiology.

  2. How problems evolve and dissolve: integrating narrative and strategic concepts.

    PubMed

    Eron, J B; Lund, T W

    1993-09-01

    This article presents an approach to therapy that links narrative and strategic concepts. The term "strategic" is used not in the prescriptive, impositional sense that has come to be associated with the method, but in terms of having a clear therapeutic direction in promoting change. The authors outline an approach to therapy that expands upon the fundamental principles of the MRI (Mental Research Institute) Brief Therapy model, elaborating more upon its constructivist premises than its prescriptive practices. They propose that by mapping how ordinary life events affect a person's preferred view, the therapist can locate the key narrative elements that shape the course of the problem and direct its solution. The authors suggest a framework for how problems evolve and dissolve. When new events are construed as contradicting family members' preferred narrative accounts, problems evolve. Problems dissolve when family members see the event, and the ideas and actions of others, as consonant with their preferred ways of being and acting.

  3. A community effort towards a knowledge-base and mathematical model of the human pathogen Salmonella Typhimurium LT2.

    PubMed

    Thiele, Ines; Hyduke, Daniel R; Steeb, Benjamin; Fankam, Guy; Allen, Douglas K; Bazzani, Susanna; Charusanti, Pep; Chen, Feng-Chi; Fleming, Ronan M T; Hsiung, Chao A; De Keersmaecker, Sigrid C J; Liao, Yu-Chieh; Marchal, Kathleen; Mo, Monica L; Özdemir, Emre; Raghunathan, Anu; Reed, Jennifer L; Shin, Sook-il; Sigurbjörnsdóttir, Sara; Steinmann, Jonas; Sudarsan, Suresh; Swainston, Neil; Thijs, Inge M; Zengler, Karsten; Palsson, Bernhard O; Adkins, Joshua N; Bumann, Dirk

    2011-01-18

    Metabolic reconstructions (MRs) are common denominators in systems biology and represent biochemical, genetic, and genomic (BiGG) knowledge-bases for target organisms by capturing currently available information in a consistent, structured manner. Salmonella enterica subspecies I serovar Typhimurium is a human pathogen, causes various diseases and its increasing antibiotic resistance poses a public health problem. Here, we describe a community-driven effort, in which more than 20 experts in S. Typhimurium biology and systems biology collaborated to reconcile and expand the S. Typhimurium BiGG knowledge-base. The consensus MR was obtained starting from two independently developed MRs for S. Typhimurium. Key results of this reconstruction jamboree include i) development and implementation of a community-based workflow for MR annotation and reconciliation; ii) incorporation of thermodynamic information; and iii) use of the consensus MR to identify potential multi-target drug therapy approaches. Taken together, with the growing number of parallel MRs a structured, community-driven approach will be necessary to maximize quality while increasing adoption of MRs in experimental design and interpretation.

  4. A community effort towards a knowledge-base and mathematical model of the human pathogen Salmonella Typhimurium LT2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thiele, Ines; Hyduke, Daniel R.; Steeb, Benjamin

    2011-01-01

    Metabolic reconstructions (MRs) are common denominators in systems biology and represent biochemical, genetic, and genomic (BiGG) knowledge-bases for target organisms by capturing currently available information in a consistent, structured manner. Salmonella enterica subspecies I serovar Typhimurium is a human pathogen, causes various diseases and its increasing antibiotic resistance poses a public health problem. Here, we describe a community-driven effort, in which more than 20 experts in S. Typhimurium biology and systems biology collaborated to reconcile and expand the S. Typhimurium BiGG knowledge-base. The consensus MR was obtained starting from two independently developed MRs for S. Typhimurium. Key results of thismore » reconstruction jamboree include i) development and implementation of a community-based workflow for MR annotation and reconciliation; ii) incorporation of thermodynamic information; and iii) use of the consensus MR to identify potential multi-target drug therapy approaches. Finally, taken together, with the growing number of parallel MRs a structured, community-driven approach will be necessary to maximize quality while increasing adoption of MRs in experimental design and interpretation.« less

  5. Capturing, using, and managing quality assurance knowledge for shuttle post-MECO flight design

    NASA Technical Reports Server (NTRS)

    Peters, H. L.; Fussell, L. R.; Goodwin, M. A.; Schultz, Roger D.

    1991-01-01

    Ascent initialization values used by the Shuttle's onboard computer for nominal and abort mission scenarios are verified by a six degrees of freedom computer simulation. The procedure that the Ascent Post Main Engine Cutoff (Post-MECO) group uses to perform quality assurance (QA) of the simulation is time consuming. Also, the QA data, checklists and associated rationale, though known by the group members, is not sufficiently documented, hindering transfer of knowledge and problem resolution. A new QA procedure which retains the current high level of integrity while reducing the time required to perform QA is needed to support the increasing Shuttle flight rate. Documenting the knowledge is also needed to increase its availability for training and problem resolution. To meet these needs, a knowledge capture process, embedded into the group activities, was initiated to verify the existing QA checks, define new ones, and document all rationale. The resulting checks were automated in a conventional software program to achieve the desired standardization, integrity, and time reduction. A prototype electronic knowledge base was developed with Macintosh's HyperCard to serve as a knowledge capture tool and data storage.

  6. Multiplexed phase-space imaging for 3D fluorescence microscopy.

    PubMed

    Liu, Hsiou-Yuan; Zhong, Jingshan; Waller, Laura

    2017-06-26

    Optical phase-space functions describe spatial and angular information simultaneously; examples of optical phase-space functions include light fields in ray optics and Wigner functions in wave optics. Measurement of phase-space enables digital refocusing, aberration removal and 3D reconstruction. High-resolution capture of 4D phase-space datasets is, however, challenging. Previous scanning approaches are slow, light inefficient and do not achieve diffraction-limited resolution. Here, we propose a multiplexed method that solves these problems. We use a spatial light modulator (SLM) in the pupil plane of a microscope in order to sequentially pattern multiplexed coded apertures while capturing images in real space. Then, we reconstruct the 3D fluorescence distribution of our sample by solving an inverse problem via regularized least squares with a proximal accelerated gradient descent solver. We experimentally reconstruct a 101 Megavoxel 3D volume (1010×510×500µm with NA 0.4), demonstrating improved acquisition time, light throughput and resolution compared to scanning aperture methods. Our flexible patterning scheme further allows sparsity in the sample to be exploited for reduced data capture.

  7. Economics of fluid therapy in critically ill patients.

    PubMed

    Lyu, Peter F; Murphy, David J

    2014-08-01

    Fluid therapy practices are an ongoing debate in critical care as evidence continues to emerge on the clinical effectiveness of different fluids and regimens. Although fluid therapy is a frequent and often costly treatment in the ICU, cost considerations have been largely absent from these studies. To facilitate a more structured approach to understanding fluid therapy costs and their role in clinical practice, we summarize currently available options and describe a framework for identifying and organizing relevant costs. Fluid therapy is a complex area of care that has been rarely studied from a cost-effectiveness perspective. We identify seven cost areas that capture fluid therapy-related costs during preutilization, point-of-utilization, and postutilization periods. These costs are driven by decisions on the type of fluid and administration strategy. Although estimates for some cost areas could be informed by medical literature, other cost areas remain unclear and require further investigation. Given the growing emphasis on the value of care, providers must recognize the important cost consequences of clinical decisions in fluid therapy. Future research into fluid therapy costs is needed and can be guided by this framework. Developing a complete cost picture is an initial and necessary step for improving values for patients, hospitals, and healthcare systems.

  8. Low-energy near Earth asteroid capture using Earth flybys and aerobraking

    NASA Astrophysics Data System (ADS)

    Tan, Minghu; McInnes, Colin; Ceriotti, Matteo

    2018-04-01

    Since the Sun-Earth libration points L1 and L2 are regarded as ideal locations for space science missions and candidate gateways for future crewed interplanetary missions, capturing near-Earth asteroids (NEAs) around the Sun-Earth L1/L2 points has generated significant interest. Therefore, this paper proposes the concept of coupling together a flyby of the Earth and then capturing small NEAs onto Sun-Earth L1/L2 periodic orbits. In this capture strategy, the Sun-Earth circular restricted three-body problem (CRTBP) is used to calculate target Lypaunov orbits and their invariant manifolds. A periapsis map is then employed to determine the required perigee of the Earth flyby. Moreover, depending on the perigee distance of the flyby, Earth flybys with and without aerobraking are investigated to design a transfer trajectory capturing a small NEA from its initial orbit to the stable manifolds associated with Sun-Earth L1/L2 periodic orbits. Finally, a global optimization is carried out, based on a detailed design procedure for NEA capture using an Earth flyby. Results show that the NEA capture strategies using an Earth flyby with and without aerobraking both have the potential to be of lower cost in terms of energy requirements than a direct NEA capture strategy without the Earth flyby. Moreover, NEA capture with an Earth flyby also has the potential for a shorter flight time compared to the NEA capture strategy without the Earth flyby.

  9. From blackbirds to black holes: Investigating capture-recapture methods for time domain astronomy

    NASA Astrophysics Data System (ADS)

    Laycock, Silas G. T.

    2017-07-01

    In time domain astronomy, recurrent transients present a special problem: how to infer total populations from limited observations. Monitoring observations may give a biassed view of the underlying population due to limitations on observing time, visibility and instrumental sensitivity. A similar problem exists in the life sciences, where animal populations (such as migratory birds) or disease prevalence, must be estimated from sparse and incomplete data. The class of methods termed Capture-Recapture is used to reconstruct population estimates from time-series records of encounters with the study population. This paper investigates the performance of Capture-Recapture methods in astronomy via a series of numerical simulations. The Blackbirds code simulates monitoring of populations of transients, in this case accreting binary stars (neutron star or black hole accreting from a stellar companion) under a range of observing strategies. We first generate realistic light-curves for populations of binaries with contrasting orbital period distributions. These models are then randomly sampled at observing cadences typical of existing and planned monitoring surveys. The classical capture-recapture methods, Lincoln-Peterson, Schnabel estimators, related techniques, and newer methods implemented in the Rcapture package are compared. A general exponential model based on the radioactive decay law is introduced which is demonstrated to recover (at 95% confidence) the underlying population abundance and duty cycle, in a fraction of the observing visits (10-50%) required to discover all the sources in the simulation. Capture-Recapture is a promising addition to the toolbox of time domain astronomy, and methods implemented in R by the biostats community can be readily called from within python.

  10. Identification of a putative protein profile associated with tamoxifen therapy resistance in breast cancer.

    PubMed

    Umar, Arzu; Kang, Hyuk; Timmermans, Annemieke M; Look, Maxime P; Meijer-van Gelder, Marion E; den Bakker, Michael A; Jaitly, Navdeep; Martens, John W M; Luider, Theo M; Foekens, John A; Pasa-Tolić, Ljiljana

    2009-06-01

    Tamoxifen resistance is a major cause of death in patients with recurrent breast cancer. Current clinical factors can correctly predict therapy response in only half of the treated patients. Identification of proteins that are associated with tamoxifen resistance is a first step toward better response prediction and tailored treatment of patients. In the present study we intended to identify putative protein biomarkers indicative of tamoxifen therapy resistance in breast cancer using nano-LC coupled with FTICR MS. Comparative proteome analysis was performed on approximately 5,500 pooled tumor cells (corresponding to approximately 550 ng of protein lysate/analysis) obtained through laser capture microdissection (LCM) from two independently processed data sets (n = 24 and n = 27) containing both tamoxifen therapy-sensitive and therapy-resistant tumors. Peptides and proteins were identified by matching mass and elution time of newly acquired LC-MS features to information in previously generated accurate mass and time tag reference databases. A total of 17,263 unique peptides were identified that corresponded to 2,556 non-redundant proteins identified with > or = 2 peptides. 1,713 overlapping proteins between the two data sets were used for further analysis. Comparative proteome analysis revealed 100 putatively differentially abundant proteins between tamoxifen-sensitive and tamoxifen-resistant tumors. The presence and relative abundance for 47 differentially abundant proteins were verified by targeted nano-LC-MS/MS in a selection of unpooled, non-microdissected discovery set tumor tissue extracts. ENPP1, EIF3E, and GNB4 were significantly associated with progression-free survival upon tamoxifen treatment for recurrent disease. Differential abundance of our top discriminating protein, extracellular matrix metalloproteinase inducer, was validated by tissue microarray in an independent patient cohort (n = 156). Extracellular matrix metalloproteinase inducer levels were higher in therapy-resistant tumors and significantly associated with an earlier tumor progression following first line tamoxifen treatment (hazard ratio, 1.87; 95% confidence interval, 1.25-2.80; p = 0.002). In summary, comparative proteomics performed on laser capture microdissection-derived breast tumor cells using nano-LC-FTICR MS technology revealed a set of putative biomarkers associated with tamoxifen therapy resistance in recurrent breast cancer.

  11. Age-related perception of stature, acceptance of therapy, and psychosocial functioning in human growth hormone-treated girls with Turner's syndrome.

    PubMed

    Lagrou, K; Xhrouet-Heinrichs, D; Heinrichs, C; Craen, M; Chanoine, J P; Malvaux, P; Bourguignon, J P

    1998-05-01

    This study evaluated the perception of stature, acceptance of therapy, and psychosocial functioning in relation to age at onset and time on treatment during 2 yr of GH therapy in 31 girls with Turner's syndrome grouped by age (group A: 3.7-5.8 yr, n = 9; group B: 7.2-11.8 yr, n = 13; group C: 12.5-16.4 yr, n = 9). The growth response after 2 yr was significant in the 3 groups when calculated in terms of growth norms for untreated Turner girls (mean increase in height SD score: +1.2, +1.5, and +1.1, respectively). The effect was less marked in terms of growth norms for normal girls, particularly in group B (+0.5 SD score). Height was perceived as a problem by most patients, except in the youngest girls at the start of treatment (group A) and in the majority of the adolescents after 2 yr of GH therapy (group C), without evidence of relation to growth response during therapy. The GH injections were fairly well accepted by all patients, except those younger than 6 yr. In all patients, expected adult height was unrealistic and became more realistic with age, whereas no consistent changes were observed in relation to growth response to GH therapy. The Child Behavior Checklist revealed elevated mean scores at the behavioral subscales of attention problems (group A and B), social problems, withdrawal, and anxiety-depression (most obviously in group B). No significant changes were seen during GH therapy. In group C, an elevated mean social problem score at the Youth Self Report and a low mean social self-esteem score at the Self-Esteem Inventory were observed before therapy and showed a significant improvement during 2 yr of GH treatment. These results, however, might be biased due to an increase in social desirability during therapy. We conclude that the perception of height, acceptance of GH therapy, and psychosocial functioning in girls with Turner's syndrome show important differences between age groups, with only slight changes observed during GH therapy.

  12. Borderline Personality Disorder in an Intermediate Psychological Therapies Service

    ERIC Educational Resources Information Center

    Ryan, Seamus; Danquah, Adam N.; Berry, Katherine; Hopper, Mary

    2017-01-01

    The intermediate psychological therapies service is provided for individuals referred with common mental health problems within the primary care psychological therapies service, but whose difficulties are longstanding and/or complex. The prevalence of borderline personality disorder (BPD) in intermediate psychological therapy services has not been…

  13. Walking Problems

    MedlinePlus

    ... as Parkinson's disease Diseases such as arthritis or multiple sclerosis Vision or balance problems Treatment of walking problems depends on the cause. Physical therapy, surgery, or mobility aids may help.

  14. Use of Representation Mapping to Capture Abstraction in Problem Solving in Different Courses in Chemistry

    ERIC Educational Resources Information Center

    Sevian, H.; Bernholt, S.; Szteinberg, G. A.; Auguste, S.; Pérez, L. C.

    2015-01-01

    A perspective is presented on how the representation mapping framework by Hahn and Chater (1998) may be used to characterize reasoning during problem solving in chemistry. To provide examples for testing the framework, an exploratory study was conducted with students and professors from three different courses in the middle of the undergraduate…

  15. Fostering Persistence: 3D Printing and the Unforeseen Impact on Equity

    ERIC Educational Resources Information Center

    FitzPatrick, Daniel L.; Dominguez, Victoria S.

    2017-01-01

    Teaching persistence and problem solving must begin with selecting a problem that can be solved mathematically, that allows for multiple methods of solving, and that generally captures the attention and curiosity of the student (Marcus and Fey 2003; NCTM 1991; Van de Walle 2003). This article shows how a STEM three-dimensional (3D) printing…

  16. The Art of Problem Solving: A Resource for the Mathematics Teacher.

    ERIC Educational Resources Information Center

    Posamentier, Alfred S.; Schulz, Wolfgang

    This book is designed to give mathematics teachers a host of interesting and useful ideas thereby raising their consciousness level and enabling an enrichment of the mathematics instruction program. The chapters in this book capture a broad spectrum of ideas in the area of mathematics problem solving. Chapters are: (1) "Strategies for Problem…

  17. Music Therapy with Children: A Review of Clinical Utility and Application to Special Populations.

    ERIC Educational Resources Information Center

    Yeaw, John David Andrew

    This paper reviews the effectiveness of music therapy in treating children with psychiatric and developmental problems. The clinical utility of music therapy is first evaluated by examining the foundational effects of music on affect and behavior. Next, the two broad approaches to music therapy, active and passive music therapy, are discussed.…

  18. A CAT scan for cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2009-01-01

    Recently, a team of scientists from Berkeley Lab, Stanford University, and the University of California, San Francisco used Berkeley Lab's National Center for X-ray Tomography to capture the changes that occur when Candida albicans is exposed to a new and promising antifungal therapy. http://newscenter.lbl.gov/feature-stories/2009/12/10/cat-scan-cells/

  19. Boron-containing amino carboxylic acid compounds and uses thereof

    DOEpatents

    Kabalka, George W.; Srivastava, Rajiv R.

    2000-03-14

    Novel compounds which are useful for boron neutron capture therapy (BNCT) are disclosed. The compounds comprise a stable boron-containing group and an aminocycloalkane carboxylic acid group or a boronated acyclic hydrocarbon-linked amino carboxylic acid. Methods for synthesis of the compounds and for use of the compounds in BNCT are disclosed.

  20. INEL BNCT Program: Volume 5, No. 9

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ackermann, A.L.

    1991-01-01

    This Bulletin presents a summary of accomplishments and highlights of the Idaho National Engineering Laboratory's (INEL) Boron Neutron Capture Therapy (BNCT) Program for September 1991. This bulletin includes information on the brain tumor and melanoma research programs, Power Burst Facility (PBF) technical support and modifications, PBF operations, and updates to the animal data charts.

  1. Filipino Arts among Elders in Institutionalized Care Settings

    ERIC Educational Resources Information Center

    de Guzman, Allan B.; Satuito, James Cyril B.; Satumba, Miko Anne E.; Segui, Diego Rey A.; Serquina, Faith Evelyn C.; Serrano, Lawrence Jan P.; Sevilla, Madelyn D.

    2011-01-01

    The use of traditional art in recreational therapies is unexplored. This paper, thus, attempts to surface the unique power of traditional Filipino arts (TFA) as synergizing lens in capturing the individual and the collective experiences of a select group of Filipino elderly in an institutionalized care setting relative to their feelings of…

  2. Interactive psychoeducational group therapy in the treatment of authority problems in combat-related posttraumatic stress disorder.

    PubMed

    Lubin, H; Johnson, D R

    2000-07-01

    The use of Interactive Psychoeducational Group Therapy to ameliorate authority problems of veterans with combat-related posttraumatic stress disorder is described. Despite the common occurrence of authority problems in this population, and the degree of damage they have caused in family, work, and legal domains, they are rarely specifically targeted by treatment interventions. A conceptual framework linking psychological trauma with distortions in authority relations is presented, followed by the format, procedures, and case examples of this form of group therapy. By uncovering the distorted beliefs associated with traumatic schemas as they emerge in the group interaction, the group therapist can first help the clients question their assumptions about authority, and then explore more adaptive behaviors. The need to examine in greater detail the causes and impact of authority problems among clients with posttraumatic stress disorder is emphasized.

  3. Targeting glioma stem cells enhances anti-tumor effect of boron neutron capture therapy

    PubMed Central

    Sun, Ting; Li, Yanyan; Huang, Yulun; Zhang, Zizhu; Yang, Weilian; Du, Ziwei; Zhou, Youxin

    2016-01-01

    The uptake of (10)boron by tumor cells plays an important role for cell damage in boron neutron capture therapy (BNCT). CD133 is frequently expressed in the membrane of glioma stem cells (GSCs), resistant to radiotherapy and chemotherapy, and represents a potential therapeutic target. To increase (10)boron uptake in GSCs, we created a polyamido amine dendrimer, conjugated CD133 monoclonal antibodies, encapsulating mercaptoundecahydrododecaborate (BSH) in void spaces, and monitored the uptake of the bioconjugate nanoparticles by GSCs in vitro and in vivo. Fluorescence microscopy showed the specific uptake of the bioconjugate nanoparticles by CD133-positive GSCs. Treatment with the biconjugate nanoparticles resulted in a significant lethal effect after neutron radiation due to efficient and CD133-independent cellular targeting and uptake in CD133-expressing GSCs. A significantly longer survival occurred in combination with the biconjugate nanoparticles and BSH compared with BSH alone in human intracranial GBM models employing CD133-positive GSCs xenografts. Our data demonstrated that this bioconjugate nanoparticle targets human CD133-positive GSCs and is a potential boron agent in BNCT. PMID:27191269

  4. Targeting glioma stem cells enhances anti-tumor effect of boron neutron capture therapy.

    PubMed

    Sun, Ting; Li, Yanyan; Huang, Yulun; Zhang, Zizhu; Yang, Weilian; Du, Ziwei; Zhou, Youxin

    2016-07-12

    The uptake of (10)boron by tumor cells plays an important role for cell damage in boron neutron capture therapy (BNCT). CD133 is frequently expressed in the membrane of glioma stem cells (GSCs), resistant to radiotherapy and chemotherapy, and represents a potential therapeutic target. To increase (10)boron uptake in GSCs, we created a polyamido amine dendrimer, conjugated CD133 monoclonal antibodies, encapsulating mercaptoundecahydrododecaborate (BSH) in void spaces, and monitored the uptake of the bioconjugate nanoparticles by GSCs in vitro and in vivo. Fluorescence microscopy showed the specific uptake of the bioconjugate nanoparticles by CD133-positive GSCs. Treatment with the biconjugate nanoparticles resulted in a significant lethal effect after neutron radiation due to efficient and CD133-independent cellular targeting and uptake in CD133-expressing GSCs. A significantly longer survival occurred in combination with the biconjugate nanoparticles and BSH compared with BSH alone in human intracranial GBM models employing CD133-positive GSCs xenografts. Our data demonstrated that this bioconjugate nanoparticle targets human CD133-positive GSCs and is a potential boron agent in BNCT.

  5. Influence of p53 status on the effects of boron neutron capture therapy in glioblastoma.

    PubMed

    Seki, Keiko; Kinashi, Yuko; Takahashi, Sentaro

    2015-01-01

    The tumor suppressor gene p53 is mutated in glioblastoma. We studied the relationship between the p53 gene and the biological effects of boron neutron capture therapy (BNCT). The human glioblastoma cells; A172, expressing wild-type p53, and T98G, with mutant p53, were irradiated by the Kyoto University Research Reactor (KUR). The biological effects after neutron irradiation were evaluated by the cell killing effect, 53BP1 foci assay and apoptosis induction. The survival-fraction data revealed that A172 was more radiosensitive than T98G, but the difference was reduced when boronophenylalanine (BPA) was present. Both cell lines exhibited similar numbers of foci, suggesting that the initial levels of DNA damage did not depend on p53 function. Detection of apoptosis revealed a lower rate of apoptosis in the T98G. BNCT causes cell death in glioblastoma cells, regardless of p53 mutation status. In T98G cells, cell killing and apoptosis occurred effectively following BNCT. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  6. Lithium Nitride Synthesized by in situ Lithium Deposition and Ion Implantation for Boron Neutron Capture Therapy

    NASA Astrophysics Data System (ADS)

    Ishitama, Shintaro; Baba, Yuji; Fujii, Ryo; Nakamura, Masaru; Imahori, Yoshio

    Li3N synthesis on Li deposition layer was conducted without H2O and O2 by in situ lithium deposition in high vacuum chamber of 10-6 Pa and ion implantation techniques and the thermo-chemical stability of the Li3N/Li/Cu tri-layered target for Boron Neutron Capture Therapy (BNCT) under laser heating and air exposure was characterized by X-ray photoelectron spectroscopy (XPS). Following conclusions were derived; (1) Li3N/Li/Cu tri-layered target with very low oxide and carbon contamination was synthesized by in situ lithium vacuum deposition and N2+ ion implantation without H2O and O2 additions, (2) The starting temperature of evaporation of Li3N/Li/Cu tri-layered target increased by 120K compared to that of the Li/Cu target and (3) Remarkable oxidation and carbon contamination were observed on the surface of Li3N/Li/Cu after air exposure and these contaminated compositions was not removed by Ar+ heavy sputtering.

  7. The accelerator neutron source for boron neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Kasatov, D.; Koshkarev, A.; Kuznetsov, A.; Makarov, A.; Ostreinov, Yu; Shchudlo, I.; Sorokin, I.; Sycheva, T.; Taskaev, S.; Zaidi, L.

    2016-11-01

    The accelerator based epithermal neutron source for Boron Neutron Capture Therapy (BNCT) is proposed, created and used in the Budker Institute of Nuclear Physics. In 2014, with the support of the Russian Science Foundation created the BNCT laboratory for the purpose to the end of 2016 get the neutron flux, suitable for BNCT. For getting 3 mA 2.3 MeV proton beam, was created a new type accelerator - tandem accelerator with vacuum isolation. On this moment, we have a stationary proton beam with 2.3 MeV and current 1.75 mA. Generation of neutrons is carried out by dropping proton beam on to lithium target as a result of threshold reaction 7Li(p,n)7Be. Established facility is a unique scientific installation. It provides a generating of neutron flux, including a monochromatic energy neutrons, gamma radiation, alpha-particles and positrons, and may be used by other research groups for carrying out scientific researches. The article describes an accelerator neutron source, presents and discusses the result of experiments and declares future plans.

  8. MAGIC polymer gel for dosimetric verification in boron neutron capture therapy

    PubMed Central

    Heikkinen, Sami; Kotiluoto, Petri; Serén, Tom; Seppälä, Tiina; Auterinen, Iiro; Savolainen, Sauli

    2007-01-01

    Radiation‐sensitive polymer gels are among the most promising three‐dimensional dose verification tools developed to date. We tested the normoxic polymer gel dosimeter known by the acronym MAGIC (methacrylic and ascorbic acid in gelatin initiated by copper) to evaluate its use in boron neutron capture therapy (BNCT) dosimetry. We irradiated a large cylindrical gel phantom (diameter: 10 cm; length: 20 cm) in the epithermal neutron beam of the Finnish BNCT facility at the FiR 1 nuclear reactor. Neutron irradiation was simulated with a Monte Carlo radiation transport code MCNP. To compare dose–response, gel samples from the same production batch were also irradiated with 6 MV photons from a medical linear accelerator. Irradiated gel phantoms then underwent magnetic resonance imaging to determine their R2 relaxation rate maps. The measured and normalized dose distribution in the epithermal neutron beam was compared with the dose distribution calculated by computer simulation. The results support the feasibility of using MAGIC gel in BNCT dosimetry. PACS numbers: 87.53.Qc, 87.53.Wz, 87.66.Ff PMID:17592463

  9. INEL BNCT Research Program Annual Report 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Venhuizen, J.R.

    1994-08-01

    This report is a summary of the progress and research produced for the Idaho National Engineering Laboratory Boron Neutron Capture Therapy Research Program for calendar year 1993. Contributions from all the principal investigators are included, covering chemistry (pituitary tumor studies, boron drug development including liposomes, lipoproteins, and carboranylalanine derivatives), pharmacology (murine screenings, toxicity testing, boron drug analysis), physics (radiation dosimetry software, neutron beam and filter design, neutron beam measurement dosimetry), and radiation biology (tissue and efficacy studies of small and large animal models). Information on the potential toxicity of borocaptate sodium and boronophenylalanine is presented. Results of 21 spontaneous-tumor-bearing dogsmore » that have been treated with boron neutron capture therapy at the Brookhaven National Laboratory are updated. Boron-containing drug purity verification is discussed in some detail. Advances in magnetic resonance imaging of boron in vivo are discussed. Several boron-carrying drugs exhibiting good tumor uptake are described. Significant progress in the potential of treating pituitary tumors is presented. Measurement of the epithermal-neutron flux of the Petten (The Netherlands) High Flux Reactor beam (HFB11B), and comparison to predictions are shown.« less

  10. [Survey on drug-related problems in Lithuania's pharmacies].

    PubMed

    Kubiliene, Loreta; Liukenskyte, Simona; Savickas, Arūnas; Jureniene, Kristina

    2006-01-01

    to survey the most common and the most important drug-related problems in Lithuania, to explore their solution and factors influencing it, to formulate recommendations for solving drug-related problems. Pharmacists from community pharmacies participated in a random survey. They filled in questionnaires about drug-related problems and their solutions. It was the first survey on drug-related problems ever carried out in Lithuania. For the first time, it was found out that in Lithuania pharmacists most commonly encountered drug-related problem--additional drug therapy (52.03% of respondents)--and most rarely encountered drug-related problem--dosage too high (3% of respondents). Pharmacists stated that all categories of drug-related problems were of equal importance. It was established that pharmacists commonly solved drug-related problems associated with noncompliance with instructions (72.5% of respondents) and rarely met the problem when improper drug was selected (39.56% of respondents). Patients taking prescription medicines commonly encounter additional drug therapy problem, and patients taking nonprescription medications commonly encounter problems related to noncompliance with instructions.

  11. Identification of a putative protein profile associating with tamoxifen therapy resistance in breast cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Umar, Arzu; Kang, Hyuk; Timmermans, A. M.

    2009-06-01

    Tamoxifen-resistance is a major cause of death in patients with recurrent breast cancer. Current clinical factors can correctly predict therapy response in only half of the treated patients. Identification of proteins that associate with tamoxifen-resistance is a first step towards better response prediction and tailored treatment of patients. In the present study we intended to identify putative protein biomarkers indicative of tamoxifen therapy-resistance in breast cancer, using nanoLC coupled with FTICR MS. Comparative proteome analysis was performed on ~5,500 pooled tumor cells (corresponding to ~550 ng protein lysate/analysis) obtained through laser capture microdissection (LCM) from two independently processed data setsmore » (n=24 and n=27) containing both tamoxifen therapy-sensitive and therapy-resistant tumors. Peptides and proteins were identified by matching mass and elution time of newly acquired LC-MS features to information in previously generated accurate mass and time tag (AMT) reference databases.« less

  12. Boron neutron capture therapy induces cell cycle arrest and cell apoptosis of glioma stem/progenitor cells in vitro

    PubMed Central

    2013-01-01

    Background Glioma stem cells in the quiescent state are resistant to clinical radiation therapy. An almost inevitable glioma recurrence is due to the persistence of these cells. The high linear energy transfer associated with boron neutron capture therapy (BNCT) could kill quiescent and proliferative cells. Methods The present study aimed to evaluate the effects of BNCT on glioma stem/progenitor cells in vitro. The damage induced by BNCT was assessed using cell cycle progression, apoptotic cell ratio and apoptosis-associated proteins expression. Results The surviving fraction and cell viability of glioma stem/progenitor cells were decreased compared with differentiated glioma cells using the same boronophenylalanine pretreatment and the same dose of neutron flux. BNCT induced cell cycle arrest in the G2/M phase and cell apoptosis via the mitochondrial pathway, with changes in the expression of associated proteins. Conclusions Glioma stem/progenitor cells, which are resistant to current clinical radiotherapy, could be effectively killed by BNCT in vitro via cell cycle arrest and apoptosis using a prolonged neutron irradiation, although radiosensitivity of glioma stem/progenitor cells was decreased compared with differentiated glioma cells when using the same dose of thermal neutron exposure and boronophenylalanine pretreatment. Thus, BNCT could offer an appreciable therapeutic advantage to prevent tumor recurrence, and may become a promising treatment in recurrent glioma. PMID:23915425

  13. Histamine reduces boron neutron capture therapy-induced mucositis in an oral precancer model.

    PubMed

    Monti Hughes, A; Pozzi, Ecc; Thorp, S I; Curotto, P; Medina, V A; Martinel Lamas, D J; Rivera, E S; Garabalino, M A; Farías, R O; Gonzalez, S J; Heber, E M; Itoiz, M E; Aromando, R F; Nigg, D W; Trivillin, V A; Schwint, A E

    2015-09-01

    Searching for more effective and selective therapies for head and neck cancer, we demonstrated the therapeutic effect of boron neutron capture therapy (BNCT) to treat oral cancer and inhibit long-term tumor development from field-cancerized tissue in the hamster cheek pouch model. However, BNCT-induced mucositis in field-cancerized tissue was dose limiting. In a clinical scenario, oral mucositis affects patients' treatment and quality of life. Our aim was to evaluate different radioprotectors, seeking to reduce the incidence of BNCT-induced severe mucositis in field-cancerized tissue. Cancerized pouches treated with BNCT mediated by boronophenylalanine at 5 Gy were treated as follows: control: saline solution; Hishigh : histamine 5 mg kg(-1) ; Hislow : histamine 1 mg kg(-1) ; and JNJ7777120: 10 mg kg(-1). Hislow reduced the incidence of severe mucositis in field-cancerized tissue to 17% vs 55%; Hishigh : 67%; JNJ7777120: 57%. Hislow was non-toxic and did not compromise the long-term therapeutic effect of BNCT or alter gross boron concentration. Histamine reduces BNCT-induced mucositis in experimental oral precancer without jeopardizing therapeutic efficacy. The fact that both histamine and boronophenylalanine are approved for use in humans bridges the gap between experimental work and potential clinical application to reduce BNCT-induced radiotoxicity in patients with head and neck cancer. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Novel Problem Solving - The NASA Solution Mechanism Guide

    NASA Technical Reports Server (NTRS)

    Keeton, Kathryn E.; Richard, Elizabeth E.; Davis, Jeffrey R.

    2014-01-01

    Over the past five years, the Human Health and Performance (HH&P) Directorate at the NASA Johnson Space Center (JSC) has conducted a number of pilot and ongoing projects in collaboration and open innovation. These projects involved the use of novel open innovation competitions that sought solutions from "the crowd", non-traditional problem solvers. The projects expanded to include virtual collaboration centers such as the NASA Human Health and Performance Center (NHHPC) and more recently a collaborative research project between NASA and the National Science Foundation (NSF). These novel problem-solving tools produced effective results and the HH&P wanted to capture the knowledge from these new tools, to teach the results to the directorate, and to implement new project management tools and coursework. The need to capture and teach the results of these novel problem solving tools, the HH&P decided to create a web-based tool to capture best practices and case studies, to teach novice users how to use new problem solving tools and to change project management training/. This web-based tool was developed with a small, multi-disciplinary group and named the Solution Mechanism Guide (SMG). An alpha version was developed that was tested against several sessions of user groups to get feedback on the SMG and determine a future course for development. The feedback was very positive and the HH&P decided to move to the beta-phase of development. To develop the web-based tool, the HH&P utilized the NASA Tournament Lab (NTL) to develop the software with TopCoder under an existing contract. In this way, the HH&P is using one new tool (the NTL and TopCoder) to develop the next generation tool, the SMG. The beta-phase of the SMG is planed for release in the spring of 2014 and results of the beta-phase testing will be available for the IAC meeting in September. The SMG is intended to disrupt the way problem solvers and project managers approach problem solving and to increase the use of novel and more cost and time effective problem solving tools such as open innovation, collaborative research, and virtual collaborative project centers. The HH&P envisions changing project management coursework by including the SMG in the teaching of project management problem solving tools.

  15. Within-Group Effect-Size Benchmarks for Problem-Solving Therapy for Depression in Adults

    ERIC Educational Resources Information Center

    Rubin, Allen; Yu, Miao

    2017-01-01

    This article provides benchmark data on within-group effect sizes from published randomized clinical trials that supported the efficacy of problem-solving therapy (PST) for depression among adults. Benchmarks are broken down by type of depression (major or minor), type of outcome measure (interview or self-report scale), whether PST was provided…

  16. Family Behavior Therapy for Substance Abuse and Other Associated Problems: A Review of Its Intervention Components and Applicability

    ERIC Educational Resources Information Center

    Donohue, Brad; Azrin, Nathan; Allen, Daniel N.; Romero, Valerie; Hill, Heather H.; Tracy, Kendra; Lapota, Holly; Gorney, Suzanne; Abdel-al, Ruweida; Caldas, Diana; Herdzik, Karen; Bradshaw, Kelsey; Valdez, Robby; Van Hasselt, Vincent B.

    2009-01-01

    A comprehensive evidence-based treatment for substance abuse and other associated problems (Family Behavior Therapy) is described, including its application to both adolescents and adults across a wide range of clinical contexts (i.e., criminal justice, child welfare). Relevant to practitioners and applied clinical researchers, topic areas include…

  17. The Effect of Cognitive Behavioral Therapy (CBT) on Depression: The Role of Problem-Solving Appraisal

    ERIC Educational Resources Information Center

    Chen, Szu-Yu; Jordan, Catheleen; Thompson, Sanna

    2006-01-01

    Objective: Many studies have confirmed the efficacy of cognitive behavioral therapy (CBT) as a treatment for depression. However, the mechanism of CBT for depression reduction is still not well understood. This study explored the mechanism of CBT from the perspective of individuals' problem-solving appraisal. Method: A one-group pretest-posttest…

  18. Emotion Regulation Enhancement of Cognitive Behavior Therapy for College Student Problem Drinkers: A Pilot Randomized Controlled Trial

    ERIC Educational Resources Information Center

    Ford, Julian D.; Grasso, Damion J.; Levine, Joan; Tennen, Howard

    2018-01-01

    This pilot randomized clinical trial tested an emotion regulation enhancement to cognitive behavior therapy (CBT) with 29 college student problem drinkers with histories of complex trauma and current clinically significant traumatic stress symptoms. Participants received eight face-to-face sessions of manualized Internet-supported CBT for problem…

  19. Effectiveness of Group Activity Play Therapy on Internalizing and Externalizing Behavior Problems of Preadolescent Orphans in Uganda

    ERIC Educational Resources Information Center

    Ojiambo, Deborah

    2011-01-01

    This pilot study investigated the impact of group activity play therapy (GAPT) on displaced orphans aged 10 to 12 years living in a large children's village in Uganda. Teachers and housemothers identified 60 preadolescents exhibiting clinical levels of internalizing and externalizing behavior problems. The participants' ethnicity was African and…

  20. A virtual patient software program to improve pharmacy student learning in a comprehensive disease management course.

    PubMed

    Douglass, Mark A; Casale, Jillian P; Skirvin, J Andrew; DiVall, Margarita V

    2013-10-14

    To implement and assess the impact of a virtual patient pilot program on pharmacy students' clinical competence skills. Pharmacy students completed interactive software-based patient case scenarios embedded with drug-therapy problems as part of a course requirement at the end of their third year. Assessments included drug-therapy problem competency achievement, performance on a pretest and posttest, and pilot evaluation survey instrument. Significant improvements in students' posttest scores demonstrated advancement of clinical skills involving drug-therapy problem solving. Students agreed that completing the pilot program improved their chronic disease management skills and the program summarized the course series well. Using virtual patient technology allowed for assessment of student competencies and improved learning outcomes.

  1. [Acceptance and commitment therapy (ACT) and addiction: a literature review].

    PubMed

    De Groot, F; Morrens, M; Dom, G

    2014-01-01

    Acceptance and commitment therapy (ACT) is a recent form of cognitive behavioural therapy, based on the relational frame theory (RFT). act is being used to treat a wide range of problems, including addiction. To review the literature on the use of act to treat addiction. We searched the literature systematically using PubMed en Psycinfo. We found 16 studies, 10 of which were rct's. Eight studies dealt with drug problems or mixed substance problems, 7 studies focused on cigarette smoking, and only 1 publication concerned alcohol treatment. The majority of studies reported positive results for act following treatment and at follow-up. Although more research is needed, act is shown itself to be a promising treatment for addiction.

  2. Successful treatment of capture myopathy in three wild greater sandhill cranes (Grus canadensis tabida).

    PubMed

    Businga, Nancy K; Langenberg, Julie; Carlson, LaVinda

    2007-12-01

    Two adult and 1 juvenile free-flying greater sandhill cranes (Grus canadensis tabida) were diagnosed with capture myopathy after alpha-chloralose baiting and physical capture during a banding and feeding ecologic study. Blood samples were collected for serum biochemical analysis at the time of capture for the 2 adults, and at 24 hours postcapture, at various intervals during treatment, and at the time of release for all 3 birds. Concentrations of creatine kinase, aspartate transaminase, and lactate dehydrogenase were high within 1 hour of capture and peaked approximately 3 days after capture. By days 10-17 after capture, creatine kinase and lactate dehydrogenase concentrations both decreased to within the reference range measured for cranes at capture, but aspartate transaminase concentrations remained 2-5 times higher than the measured reference range. Treatment consisted of corticosteroids, selenium/vitamin E, parenteral fluids, and gavage feedings. Physical therapy consisted of assisting the cranes to stand and walk 2-8 times a day, massaging leg muscles, and moving limbs manually through the range of motion. The adults were released when they were able to stand up independently and were pacing in the pen. The juvenile was released 12 hours after it was able to stand independently but was returned to the pen when it fell and could not rise. It was treated supportively for an additional 3 days and then successfully released. Both adult cranes were observed on their territories with their original mates after release and returned to their territories for the subsequent 8 years, raising chicks most years. After release, the juvenile was observed in a flock of cranes near its natal territory for the next 2 days.

  3. Microfluidic device with integrated microfilter of conical-shaped holes for high efficiency and high purity capture of circulating tumor cells

    NASA Astrophysics Data System (ADS)

    Tang, Yadong; Shi, Jian; Li, Sisi; Wang, Li; Cayre, Yvon E.; Chen, Yong

    2014-08-01

    Capture of circulating tumor cells (CTCs) from peripheral blood of cancer patients has major implications for metastatic detection and therapy analyses. Here we demonstrated a microfluidic device for high efficiency and high purity capture of CTCs. The key novelty of this approach lies on the integration of a microfilter with conical-shaped holes and a micro-injector with cross-flow components for size dependent capture of tumor cells without significant retention of non-tumor cells. Under conditions of constant flow rate, tumor cells spiked into phosphate buffered saline could be recovered and then cultured for further analyses. When tumor cells were spiked in blood of healthy donors, they could also be recovered at high efficiency and high clearance efficiency of white blood cells. When the same device was used for clinical validation, CTCs could be detected in blood samples of cancer patients but not in that of healthy donors. Finally, the capture efficiency of tumor cells is cell-type dependent but the hole size of the filter should be more closely correlated to the nuclei size of the tumor cells. Together with the advantage of easy operation, low-cost and high potential of integration, this approach offers unprecedented opportunities for metastatic detection and cancer treatment monitoring.

  4. Psycho-education with problem solving (PEPS) therapy for adults with personality disorder: a pragmatic multi-site community-based randomised clinical trial.

    PubMed

    McMurran, Mary; Crawford, Mike J; Reilly, Joseph G; McCrone, Paul; Moran, Paul; Williams, Hywel; Adams, Clive E; Duggan, Conor; Delport, Juan; Whitham, Diane; Day, Florence

    2011-08-24

    Impairment in social functioning is a key component of personality disorder. Therefore psycho-education and problem solving (PEPS) therapy may benefit people with this disorder. Psycho-education aims to educate, build rapport, and motivate people for problem solving therapy. Problem solving therapy aims to help clients solve interpersonal problems positively and rationally, thereby improving social functioning and reducing distress. PEPS therapy has been evaluated with community adults with personality disorder in an exploratory trial. At the end of treatment, compared to a wait-list control group, those treated with PEPS therapy showed better social functioning, as measured by the Social Functioning Questionnaire (SFQ). A definitive evaluation is now being conducted to determine whether PEPS therapy is a clinically and cost-effective treatment for people with personality disorder This is a pragmatic, two-arm, multi-centre, parallel, randomised controlled clinical trial. The target population is community-dwelling adults with one or more personality disorder, as identified by the International Personality Disorder Examination (IPDE). Inclusion criteria are: Living in the community (including residential or supported care settings); presence of one or more personality disorder; aged 18 or over; proficiency in spoken English; capacity to provide informed consent. Exclusion criteria are: Primary diagnosis of a functional psychosis; insufficient degree of literacy, comprehension or attention to be able to engage in trial therapy and assessments; currently engaged in a specific programme of psychological treatment for personality disorder or likely to start such treatment during the trial period; currently enrolled in any other trial. Suitable participants are randomly allocated to PEPS therapy plus treatment as usual (TAU) or TAU only. We aim to recruit 340 men and women. The primary outcome is social functioning as measured by the SFQ. A reduction (i.e., an improvement) of 2 points or more on the SFQ at follow-up 72 weeks post-randomisation is our pre-specified index of clinically significant change. Secondary outcomes include a reduction of unscheduled service usage and an increase in scheduled service usage; improved quality of life; and a reduction in mental distress. PEPS therapy has potential as an economical, accessible, and acceptable intervention for people with personality disorder. The results from this randomised controlled trial will tell us if PEPS therapy is effective and cost-effective. If so, then it will be a useful treatment for inclusion in a broader menu of treatment options for this group of service users. International Standard Randomised Controlled Trial Number - ISRCTN70660936.

  5. Psycho-education with problem solving (PEPS) therapy for adults with personality disorder: A pragmatic multi-site community-based randomised clinical trial

    PubMed Central

    2011-01-01

    Background Impairment in social functioning is a key component of personality disorder. Therefore psycho-education and problem solving (PEPS) therapy may benefit people with this disorder. Psycho-education aims to educate, build rapport, and motivate people for problem solving therapy. Problem solving therapy aims to help clients solve interpersonal problems positively and rationally, thereby improving social functioning and reducing distress. PEPS therapy has been evaluated with community adults with personality disorder in an exploratory trial. At the end of treatment, compared to a wait-list control group, those treated with PEPS therapy showed better social functioning, as measured by the Social Functioning Questionnaire (SFQ). A definitive evaluation is now being conducted to determine whether PEPS therapy is a clinically and cost-effective treatment for people with personality disorder Methods This is a pragmatic, two-arm, multi-centre, parallel, randomised controlled clinical trial. The target population is community-dwelling adults with one or more personality disorder, as identified by the International Personality Disorder Examination (IPDE). Inclusion criteria are: Living in the community (including residential or supported care settings); presence of one or more personality disorder; aged 18 or over; proficiency in spoken English; capacity to provide informed consent. Exclusion criteria are: Primary diagnosis of a functional psychosis; insufficient degree of literacy, comprehension or attention to be able to engage in trial therapy and assessments; currently engaged in a specific programme of psychological treatment for personality disorder or likely to start such treatment during the trial period; currently enrolled in any other trial. Suitable participants are randomly allocated to PEPS therapy plus treatment as usual (TAU) or TAU only. We aim to recruit 340 men and women. The primary outcome is social functioning as measured by the SFQ. A reduction (i.e., an improvement) of 2 points or more on the SFQ at follow-up 72 weeks post-randomisation is our pre-specified index of clinically significant change. Secondary outcomes include a reduction of unscheduled service usage and an increase in scheduled service usage; improved quality of life; and a reduction in mental distress. Discussion PEPS therapy has potential as an economical, accessible, and acceptable intervention for people with personality disorder. The results from this randomised controlled trial will tell us if PEPS therapy is effective and cost-effective. If so, then it will be a useful treatment for inclusion in a broader menu of treatment options for this group of service users. Trial Registration International Standard Randomised Controlled Trial Number - ISRCTN70660936 PMID:21864370

  6. Art Therapy in Theory & Practice.

    ERIC Educational Resources Information Center

    Ulman, Elinor, Ed.; Dachinger, Penny, Ed.

    The essays in this collection are grounded in theoretical underpinnings which range from Freud to Montessori. The focus encompasses educational and psychiatric concerns. Essays are organized in 4 parts. Part 1, "Theory of Art Therapy," includes: (1) "Art Therapy: Problems of Definition" (Elinor Ulman); (2) "Therapy is Not Enough: The Contribution…

  7. Play Therapy: A Review

    ERIC Educational Resources Information Center

    Porter, Maggie L.; Hernandez-Reif, Maria; Jessee, Peggy

    2009-01-01

    This article discusses the current issues in play therapy and its implications for play therapists. A brief history of play therapy is provided along with the current play therapy approaches and techniques. This article also touches on current issues or problems that play therapists may face, such as interpreting children's play, implementing…

  8. Mechanical Chevrons and Fluidics for Advanced Military Aircraft Noise Reduction

    DTIC Science & Technology

    2011-03-01

    at or near the nozzle lip. Therefore, for the problem at hand, the simulations will need to accurately capture shock waves , unsteady large-scale...simulations could accurately capture the flow field and near-field noise from representative jet engine nozzles and indeed this was a go/no-go...mixing noise. The first two types of noise are related to the shock waves that are present in the high-speed jet flow. While the mixing noise

  9. From analytic inversion to contemporary IMRT optimization: Radiation therapy planning revisited from a mathematical perspective

    PubMed Central

    Censor, Yair; Unkelbach, Jan

    2011-01-01

    In this paper we look at the development of radiation therapy treatment planning from a mathematical point of view. Historically, planning for Intensity-Modulated Radiation Therapy (IMRT) has been considered as an inverse problem. We discuss first the two fundamental approaches that have been investigated to solve this inverse problem: Continuous analytic inversion techniques on one hand, and fully-discretized algebraic methods on the other hand. In the second part of the paper, we review another fundamental question which has been subject to debate from the beginning of IMRT until the present day: The rotation therapy approach versus fixed angle IMRT. This builds a bridge from historic work on IMRT planning to contemporary research in the context of Intensity-Modulated Arc Therapy (IMAT). PMID:21616694

  10. A Piagetian view of family therapy: Selvini-Palazzoli and the Invariant Approach.

    PubMed

    Gelcer, E; Schwartzbein, D

    1989-12-01

    The Invariant Approach of Mara Selvini-Palazzoli is a new development in the Milan approach to family therapy. In order to distinguish and explain it, an overview of the Invariant Approach is given. Jean Piaget's theory of cognitive development is used to provide a framework for explaining how Selvini-Palazzoli's therapy alters the family's epistemology and facilitates change in the "family game." It is suggested that family members in therapy tend to think about their problems in a style that resembles Piaget's preoperational period. The process of therapy can be seen as geared to facilitate a shift from a preoperational to an operational style of cognitive functioning. This shift gives family members access to more adaptive ways of thinking about their problem-solving strategies.

  11. Spacecraft Stabilization and Control for Capture of Non-Cooperative Space Objects

    NASA Technical Reports Server (NTRS)

    Joshi, Suresh; Kelkar, Atul G.

    2014-01-01

    This paper addresses stabilization and control issues in autonomous capture and manipulation of non-cooperative space objects such as asteroids, space debris, and orbital spacecraft in need of servicing. Such objects are characterized by unknown mass-inertia properties, unknown rotational motion, and irregular shapes, which makes it a challenging control problem. The problem is further compounded by the presence of inherent nonlinearities, signi cant elastic modes with low damping, and parameter uncertainties in the spacecraft. Robust dissipativity-based control laws are presented and are shown to provide global asymptotic stability in spite of model uncertainties and nonlinearities. It is shown that robust stabilization can be accomplished via model-independent dissipativity-based controllers using thrusters alone, while stabilization with attitude and position control can be accomplished using thrusters and torque actuators.

  12. Motion data classification on the basis of dynamic time warping with a cloud point distance measure

    NASA Astrophysics Data System (ADS)

    Switonski, Adam; Josinski, Henryk; Zghidi, Hafedh; Wojciechowski, Konrad

    2016-06-01

    The paper deals with the problem of classification of model free motion data. The nearest neighbors classifier which is based on comparison performed by Dynamic Time Warping transform with cloud point distance measure is proposed. The classification utilizes both specific gait features reflected by a movements of subsequent skeleton joints and anthropometric data. To validate proposed approach human gait identification challenge problem is taken into consideration. The motion capture database containing data of 30 different humans collected in Human Motion Laboratory of Polish-Japanese Academy of Information Technology is used. The achieved results are satisfactory, the obtained accuracy of human recognition exceeds 90%. What is more, the applied cloud point distance measure does not depend on calibration process of motion capture system which results in reliable validation.

  13. Benchmark Problems for Space Mission Formation Flying

    NASA Technical Reports Server (NTRS)

    Carpenter, J. Russell; Leitner, Jesse A.; Folta, David C.; Burns, Richard

    2003-01-01

    To provide a high-level focus to distributed space system flight dynamics and control research, several benchmark problems are suggested for space mission formation flying. The problems cover formation flying in low altitude, near-circular Earth orbit, high altitude, highly elliptical Earth orbits, and large amplitude lissajous trajectories about co-linear libration points of the Sun-Earth/Moon system. These problems are not specific to any current or proposed mission, but instead are intended to capture high-level features that would be generic to many similar missions that are of interest to various agencies.

  14. Symmetric and asymmetric halogen-containing metallocarboranylporphyrins and uses thereof

    DOEpatents

    Miura, Michiko; Wu, Haitao

    2013-05-21

    The present invention is directed to low toxicity boronated compounds and methods for their use in the treatment, visualization, and diagnosis of tumors. More specifically, the present invention is directed to low toxicity halogenated, carborane-containing 5,10,15,20-tetraphenylporphyrin compounds and methods for their use particularly in boron neutron capture therapy (BNCT) and photodynamic therapy (PDT) for the treatment of tumors of the brain, head and neck, and surrounding tissue. The invention is also directed to using these halogenated, carborane-containing tetraphenylporphyrin compounds in methods of tumor imaging and/or diagnosis such as MRI, SPECT, or PET.

  15. Light field reconstruction robust to signal dependent noise

    NASA Astrophysics Data System (ADS)

    Ren, Kun; Bian, Liheng; Suo, Jinli; Dai, Qionghai

    2014-11-01

    Capturing four dimensional light field data sequentially using a coded aperture camera is an effective approach but suffers from low signal noise ratio. Although multiplexing can help raise the acquisition quality, noise is still a big issue especially for fast acquisition. To address this problem, this paper proposes a noise robust light field reconstruction method. Firstly, scene dependent noise model is studied and incorporated into the light field reconstruction framework. Then, we derive an optimization algorithm for the final reconstruction. We build a prototype by hacking an off-the-shelf camera for data capturing and prove the concept. The effectiveness of this method is validated with experiments on the real captured data.

  16. Rapid identification and susceptibility testing of uropathogenic microbes via immunosorbent ATP-bioluminescence assay on a microfluidic simulator for antibiotic therapy.

    PubMed

    Dong, Tao; Zhao, Xinyan

    2015-02-17

    The incorporation of pathogen identification with antimicrobial susceptibility testing (AST) was implemented on a concept microfluidic simulator, which is well suited for personalizing antibiotic treatment of urinary tract infections (UTIs). The microfluidic device employs a fiberglass membrane sandwiched between two polypropylene components, with capture antibodies immobilized on the membrane. The chambers in the microfluidic device share the same geometric distribution as the wells in a standard 384-well microplate, resulting in compatibility with common microplate readers. Thirteen types of common uropathogenic microbes were selected as the analytes in this study. The microbes can be specifically captured by various capture antibodies and then quantified via an ATP bioluminescence assay (ATP-BLA) either directly or after a variety of follow-up tests, including urine culture, antibiotic treatment, and personalized antibiotic therapy simulation. Owing to the design of the microfluidic device, as well as the antibody specificity and the ATP-BLA sensitivity, the simulator was proven to be able to identify UTI pathogen species in artificial urine samples within 20 min and to reliably and simultaneously verify the antiseptic effects of eight antibiotic drugs within 3-6 h. The measurement range of the device spreads from 1 × 10(3) to 1 × 10(5) cells/mL in urine samples. We envision that the medical simulator might be broadly employed in UTI treatment and could serve as a model for the diagnosis and treatment of other diseases.

  17. Hybrid Capture-Based Tumor Sequencing and Copy Number Analysis to Confirm Origin of Metachronous Metastases in BRCA1-Mutant Cholangiocarcinoma Harboring a Novel YWHAZ-BRAF Fusion.

    PubMed

    Lim, Huat C; Montesion, Meagan; Botton, Thomas; Collisson, Eric A; Umetsu, Sarah E; Behr, Spencer C; Gordan, John D; Stephens, Phil J; Kelley, Robin K

    2018-04-05

    Biliary tract cancers such as cholangiocarcinoma represent a heterogeneous group of cancers that can be difficult to diagnose. Recent comprehensive genomic analyses in large cholangiocarcinoma cohorts have defined important molecular subgroups within cholangiocarcinoma that may relate to anatomic location and etiology [1-4] and may predict responsiveness to targeted therapies in development [5-7]. These emerging data highlight the potential for tumor genomics to inform diagnosis and treatment options in this challenging tumor type. We report the case of a patient with a germline BRCA1 mutation who presented with a cholangiocarcinoma driven by the novel YWHAZ-BRAF fusion. Hybrid capture-based DNA sequencing and copy number analysis performed as part of clinical care demonstrated that two later-occurring tumors were clonally derived from the primary cholangiocarcinoma rather than distinct new primaries, revealing an unusual pattern of late metachronous metastasis. We discuss the clinical significance of these genetic alterations and their relevance to therapeutic strategies. Hybrid capture-based next-generation DNA sequencing assays can provide diagnostic clarity in patients with unusual patterns of metastasis and recurrence in which the pathologic diagnosis is ambiguous.To our knowledge, this is the first reported case of a YWHAZ-BRAF fusion in pancreaticobiliary cancer, and a very rare case of cholangiocarcinoma in the setting of a germline BRCA1 mutation.The patient's BRCA1 mutation and YWHAZ-BRAF fusion constitute potential targets for future therapy. © AlphaMed Press 2018.

  18. Radiobiological response of U251MG, CHO-K1 and V79 cell lines to accelerator-based boron neutron capture therapy

    PubMed Central

    Sato, Eisuke; Zaboronok, Alexander; Yamamoto, Tetsuya; Nakai, Kei; Taskaev, Sergey; Volkova, Olga; Mechetina, Ludmila; Taranin, Alexander; Kanygin, Vladimir; Isobe, Tomonori; Mathis, Bryan J; Matsumura, Akira

    2018-01-01

    Abstract In the current article, we provide in vitro efficacy evaluation of a unique accelerator-based neutron source, constructed at the Budker Institute of Nuclear Physics (Novosibirsk, Russian Federation), for boron neutron capture therapy (BNCT), which is particularly effective in the case of invasive cancers. U251MG, CHO-K1 and V79 cells were incubated and irradiated in various concentrations of boric acid with epithermal neutrons for 2–3 h in a plexiglass phantom, using 2.0 MeV proton energy and 1.5–3.0 mA proton current, resulting in a neutron fluence of 2.16 × 1012 cm−2. The survival curves of cells loaded with boron were normalized to those irradiated without boron (to exclude the influence of the fast neutron and gamma dose components) and fit to the linear–quadratic (LQ) model. Colony formation assays showed the following cell survival rates (means ± SDs): CHO-K1: 0.348 ± 0.069 (10 ppm), 0.058 ± 0.017 (20 ppm), 0.018 ± 0.005 (40 ppm); V79: 0.476 ± 0.160 (10 ppm), 0.346 ± 0.053 (20 ppm), 0.078 ± 0.015 (40 ppm); and U251MG: 0.311 ± 0.061 (10 ppm), 0.131 ± 0.022 (20 ppm), 0.020 ± 0.010 (40 ppm). The difference between treated cells and controls was significant in all cases (P < 0.01) and confirmed that the neutron source and irradiation regimen were sufficient for control over cell colony formation. We believe our study will serve as a model for ongoing in vitro experiments on neutron capture therapy to advance in this area for further development of accelerator-based BNCT into the clinical phase. PMID:29281044

  19. Validation and Comparison of the Therapeutic Efficacy of Boron Neutron Capture Therapy Mediated By Boron-Rich Liposomes in Multiple Murine Tumor Models

    DOE PAGES

    Maitz, Charles A.; Khan, Aslam A.; Kueffer, Peter J.; ...

    2017-08-01

    Boron neutron capture therapy (BNCT) was performed at the University of Missouri Research Reactor in mice bearing CT26 colon carcinoma flank tumors and the results were compared with previously performed studies with mice bearing EMT6 breast cancer flank tumors. We implanted mice with CT26 tumors subcutaneously in the caudal flank and were given two separate tail vein injections of unilamellar liposomes composed of cholesterol, 1,2-distearoyl-sn-glycer-3-phosphocholine, and K[nido-7-CH 3(CH 2) 15–7,8-C 2B 9H 11] in the lipid bilayer and encapsulated Na 3[1-(2`-B 10H 9)-2-NH 3B 10H 8] within the liposomal core. Mice were irradiated 30 hours after the second injection inmore » a thermal neutron beam for various lengths of time. The tumor size was monitored daily for 72 days. In spite of relatively lower tumor boron concentrations, as compared to EMT6 tumors, a 45 minute neutron irradiation BNCT resulted in complete resolution of the tumors in 50% of treated mice, 50% of which never recurred. Median time to tumor volume tripling was 38 days in BNCT treated mice, 17 days in neutron-irradiated mice given no boron compounds, and 4 days in untreated controls. Tumor response in mice with CT26 colon carcinoma was markedly more pronounced than in previous reports of mice with EMT6 tumors, a difference which increased with dose. The slope of the dose response curve of CT26 colon carcinoma tumors is 1.05 times tumor growth delay per Gy compared to 0.09 times tumor growth delay per Gy for EMT6 tumors, indicating that inherent radiosensitivity of tumors plays a role in boron neutron capture therapy and should be considered in the development of clinical applications of BNCT in animals and man.« less

  20. Validation and Comparison of the Therapeutic Efficacy of Boron Neutron Capture Therapy Mediated By Boron-Rich Liposomes in Multiple Murine Tumor Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maitz, Charles A.; Khan, Aslam A.; Kueffer, Peter J.

    Boron neutron capture therapy (BNCT) was performed at the University of Missouri Research Reactor in mice bearing CT26 colon carcinoma flank tumors and the results were compared with previously performed studies with mice bearing EMT6 breast cancer flank tumors. We implanted mice with CT26 tumors subcutaneously in the caudal flank and were given two separate tail vein injections of unilamellar liposomes composed of cholesterol, 1,2-distearoyl-sn-glycer-3-phosphocholine, and K[nido-7-CH 3(CH 2) 15–7,8-C 2B 9H 11] in the lipid bilayer and encapsulated Na 3[1-(2`-B 10H 9)-2-NH 3B 10H 8] within the liposomal core. Mice were irradiated 30 hours after the second injection inmore » a thermal neutron beam for various lengths of time. The tumor size was monitored daily for 72 days. In spite of relatively lower tumor boron concentrations, as compared to EMT6 tumors, a 45 minute neutron irradiation BNCT resulted in complete resolution of the tumors in 50% of treated mice, 50% of which never recurred. Median time to tumor volume tripling was 38 days in BNCT treated mice, 17 days in neutron-irradiated mice given no boron compounds, and 4 days in untreated controls. Tumor response in mice with CT26 colon carcinoma was markedly more pronounced than in previous reports of mice with EMT6 tumors, a difference which increased with dose. The slope of the dose response curve of CT26 colon carcinoma tumors is 1.05 times tumor growth delay per Gy compared to 0.09 times tumor growth delay per Gy for EMT6 tumors, indicating that inherent radiosensitivity of tumors plays a role in boron neutron capture therapy and should be considered in the development of clinical applications of BNCT in animals and man.« less

  1. Problem behaviours and parenting in preschool children with cystic fibrosis.

    PubMed

    Ward, C; Massie, J; Glazner, J; Sheehan, J; Canterford, L; Armstrong, D; Jaffe, A; Hiscock, H

    2009-05-01

    Problems with sleep, eating and adherence to therapy may adversely affect health outcomes in children with cystic fibrosis (CF). Data on the prevalence of such problems, associated parenting styles and caregiver mental health are limited. To determine: (a) the prevalence of sleep, mealtime, therapy adherence and externalising and internalising behavioural problems in preschool children with CF; (b) the prevalence of caregiver mental health problems and poor sleep quality; and (c) associations between child behavioural problems and parenting styles. This was a cross sectional survey of caregivers of children aged 6 months to 5 years attending CF outpatient clinics at Royal Children's Hospital (Melbourne), Monash Medical Centre (Melbourne) and Sydney Children's Hospital. Main outcome measures were child externalising and internalising behaviours, sleep, eating and adherence with therapy; the predictor was parenting styles (harsh, inconsistent, overprotective). 117 of 139 families participated. Problems were common with child sleep (small 31.6%; moderate/large problem: 21.9%), eating (32.4%) and adherence with physiotherapy (50.4%). Compared to normative data, sleep and mealtime problems were more prevalent. Caregivers reported high rates of symptoms indicating depression (33.3%), anxiety (16.4%) and stress (34.2%). Harsh parenting was associated with internalising behaviours (adjusted OR 3.9, 95% CI 1.16 to 13.17, p = 0.03). Problems with sleeping, eating and physiotherapy adherence were common in preschool children with CF. Caregivers reported high rates of symptoms indicative of mental health problems. Harsh parenting was associated with internalising problems. An intervention targeting child problem behaviours and parental mental health would be appropriate for CF families.

  2. Longitudinal Assessment of Neurocognitive Outcomes in Survivors of Childhood Acute Lymphoblastic Leukemia Treated on a Contemporary Chemotherapy Protocol.

    PubMed

    Jacola, Lisa M; Krull, Kevin R; Pui, Ching-Hon; Pei, Deqing; Cheng, Cheng; Reddick, Wilburn E; Conklin, Heather M

    2016-04-10

    Survivors of childhood acute lymphoblastic leukemia (ALL) treated with CNS-directed chemotherapy are at risk for neurocognitive deficits. Prospective longitudinal studies are needed to clarify the neurodevelopmental trajectory in this vulnerable population. Patients enrolled in the St. Jude Total Therapy Study XV, which omitted prophylactic cranial radiation therapy in all patients, completed comprehensive neuropsychological assessments at induction (n = 142), end of maintenance (n = 243), and 2 years after completion of therapy (n = 211). We report on longitudinal change in neurocognitive function and predictors of neurocognitive outcomes 2 years after completing therapy. Neurocognitive function was largely age appropriate 2 years after completing therapy; however, the overall group demonstrated significant attention deficits and a significantly greater frequency of learning problems as compared with national normative data (all P ≤ .005). Higher-intensity CNS-directed chemotherapy conferred elevated risk for difficulties in attention, processing speed, and academics (all P ≤ .01). The rate and direction of change in performance and caregiver-reported attention difficulties differed significantly by age at diagnosis and sex. End-of-therapy attention problems predicted lower academic scores 2 years later, with small to moderate effect sizes (│r│= 0.17 to 0.25, all P ≤ .05). Two years after chemotherapy-only treatment, neurocognitive function is largely age appropriate. Nonetheless, survivors remain at elevated risk for attention problems that impact real-world functioning. Attention problems at the end of therapy predicted decreased academics 2 years later, suggesting an amplified functional impact of discrete neurocognitive difficulties. Age at diagnosis and patient sex may alter neurocognitive development in survivors of childhood ALL treated with chemotherapy-only protocols. © 2016 by American Society of Clinical Oncology.

  3. Validated Measures of Illness Perception and Behavior in People with Knee Pain and Knee Osteoarthritis: A Scoping Review.

    PubMed

    Hamilton, Clayon B; Wong, Ming-Kin; Gignac, Monique A M; Davis, Aileen M; Chesworth, Bert M

    2017-01-01

    To identify validated measures that capture illness perception and behavior and have been used to assess people who have knee pain/osteoarthritis. A scoping review was performed. Nine electronic databases were searched for records from inception through April 19, 2015. Search terms included illness perception, illness behavior, knee, pain, osteoarthritis, and their related terms. This review included English language publications of primary data on people with knee pain/osteoarthritis who were assessed with validated measures capturing any of 4 components of illness perception and behavior: monitor body, define and interpret symptoms, take remedial action, and utilize sources of help. Seventy-one publications included relevant measures. Two reviewers independently coded and analyzed each relevant measure within the 4 components. Sixteen measures were identified that capture components of illness perception and behavior in the target population. These measures were originally developed to capture constructs that include coping strategies/skills/styles, illness belief, illness perception, self-efficacy, and pain behavior. Coding results indicated that 5, 11, 12, and 5 of these measures included the monitor body, define and interpret symptoms, take remedial action, and utilize sources of help components, respectively. Several validated measures were interpreted as capturing some components, and only 1 measure was interpreted as capturing all of the components of illness perception and behavior in the target population. A measure that comprehensively captures illness perception and behavior could be valuable for informing and evaluating therapy for patients along a continuum of symptomatic knee osteoarthritis. © 2016 World Institute of Pain.

  4. [Frequency and consequences of financial problems in patients undergoing outpatient psychosomatic treatment].

    PubMed

    Wagner, Stefanie; Münster, Eva; Beutel, Manfred E

    2010-01-01

    About seven million people in Germany are affected by overindebtedness and insolvency. Being severely in debt is a very stressful situation that can result in social marginalisation, reducted overall activity, and physical and mental illness. The present study investigated the frequency of financial problems and their effects on physical and mental disorders at a university psychosomatic clinic. The study included a total of 659 patients. Their mental status was assessed with the Symptom Checklist (SCL-90-R), their physical status with the Gießener Beschwerdebogen (GBB). 37 percent of the subjects reported experiencing financial problems. We found that subjects with financial problems reported more physical and mental disorders than those without financial problems. Furthermore, therapists more often recommended that patients with financial problems receive inpatient therapy than patients without financial problems. The study suggests that financial problems should be included in any anamnesis, therapeutic recommendation, and actual therapy of patients in psychosomatic treatment.

  5. Modular Approach to Therapy for Anxiety, Depression, Trauma, or Conduct Problems in outpatient child and adolescent mental health services in New Zealand: study protocol for a randomized controlled trial.

    PubMed

    Lucassen, Mathijs F G; Stasiak, Karolina; Crengle, Sue; Weisz, John R; Frampton, Christopher M A; Bearman, Sarah Kate; Ugueto, Ana M; Herren, Jennifer; Cribb-Su'a, Ainsleigh; Faleafa, Monique; Kingi-'Ulu'ave, Denise; Loy, Jik; Scott, Rebecca M; Hartdegen, Morgyn; Merry, Sally N

    2015-10-12

    Mental health disorders are common and disabling for young people because of the potential to disrupt key developmental tasks. Implementation of evidence-based psychosocial therapies in New Zealand is limited, owing to the inaccessibility, length, and cost of training in these therapies. Furthermore, most therapies address one problem area at a time, although comorbidity and changing clinical needs commonly occur in practice. A more flexible approach is needed. The Modular Approach to Therapy for Children with Anxiety, Depression, Trauma, or Conduct Problems (MATCH-ADTC) is designed to overcome these challenges; it provides a range of treatment modules addressing different problems, within a single training program. A clinical trial of MATCH-ADTC in the USA showed that MATCH-ADTC outperformed usual care and standard evidence-based treatment on several clinical measures. We aim to replicate these findings and evaluate the impact of providing training and supervision in MATCH-ADTC to: (1) improve clinical outcomes for youth attending mental health services; (2) increase the amount of evidence-based therapy content; (3) increase the efficiency of service delivery. This is an assessor-blinded multi-site effectiveness randomized controlled trial. Randomization occurs at two levels: (1) clinicians (≥60) are randomized to intervention or usual care; (2) youth participants (7-14 years old) accepted for treatment in child and adolescent mental health services (with a primary disorder that includes anxiety, depression, trauma-related symptoms, or disruptive behavior) are randomly allocated to receive MATCH-ADTC or usual care. Youth participants are recruited from 'mainstream', Māori-specific, and Pacific-specific child and adolescent mental health services. We originally planned to recruit 400 youth participants, but this has been revised to 200 participants. Centralized computer randomization ensures allocation concealment. The primary outcome measures are: (i) the difference in trajectory of change of clinical severity between groups (using the parent-rated Brief Problem Monitor); (ii) clinicians' use of evidence-based treatment procedures during therapy sessions; (iii) total time spent by clinicians delivering therapy. If MATCH-ADTC demonstrates effectiveness it could offer a practical efficient method to increase access to evidence-based therapies, and improve outcomes for youth attending secondary care services. Australian and New Zealand Clinical Trials Registry ACTRN12614000297628 .

  6. Is It All about the Higher Dose? Why Psychoanalytic Therapy Is an Effective Treatment for Major Depression.

    PubMed

    Zimmermann, Johannes; Löffler-Stastka, Henriette; Huber, Dorothea; Klug, Günther; Alhabbo, Sarah; Bock, Astrid; Benecke, Cord

    2015-01-01

    Empirical evidence for the effectiveness of long-term psychodynamic psychotherapy (LTPP) in patients with mood disorders is growing. However, it is unclear whether the effectiveness of LTPP is due to distinctive features of psychodynamic/psychoanalytic techniques or to a higher number of sessions. We tested these rival hypotheses in a quasi-experimental study comparing psychoanalytic therapy (i.e., high-dose LTPP) with psychodynamic therapy (i.e., low-dose LTPP) and cognitive-behavioural therapy (CBT) for depression. Analyses were based on a subsample of 77 subjects, with 27 receiving psychoanalytic therapy, 26 receiving psychodynamic therapy and 24 receiving CBT. Depressive symptoms, interpersonal problems and introject affiliation were assessed prior to treatment, after treatment and at the 1-, 2- and 3-year follow-ups. Psychoanalytic techniques were assessed from three audiotaped middle sessions per treatment using the Psychotherapy Process Q-Set. Subjects receiving psychoanalytic therapy reported having fewer interpersonal problems, treated themselves in a more affiliative way directly after treatment and tended to improve in depressive symptoms and interpersonal problems during follow-up as compared with patients receiving psychodynamic therapy and/or CBT. Multilevel mediation analyses suggested that post-treatment differences in interpersonal problems and introject affiliation were mediated by the higher number of sessions, and follow-up differences in depressive symptoms were mediated by the more pronounced application of psychoanalytic techniques. We also found some evidence for indirect treatment effects via psychoanalytic techniques on changes in introject affiliation during follow-up. These results provide support for the prediction that both a high dose and the application of psychoanalytic techniques facilitate therapeutic change in patients with major depression. Psychoanalytic therapy is an effective treatment for major depression, especially in the long run. The differential effectiveness of psychoanalytic therapy cannot be fully explained by its higher dose. Distinctive features of psychoanalytic technique (e.g., focusing on patients' dreams, fantasies, sexual experiences or childhood memories) may play an important role in establishing sustained therapeutic change. Copyright © 2014 John Wiley & Sons, Ltd.

  7. Interpersonal Problems Predict Differential Response to Cognitive Versus Behavioral Treatment in a Randomized Controlled Trial

    PubMed Central

    Newman, Michelle G.; Jacobson, Nicholas C.; Erickson, Thane M.; Fisher, Aaron J.

    2016-01-01

    Objective We examined dimensional interpersonal problems as moderators of cognitive behavioral therapy (CBT) versus its components (cognitive therapy [CT] and behavioral therapy [BT]). We predicted that people with generalized anxiety disorder (GAD) whose interpersonal problems reflected more dominance and intrusiveness would respond best to a relaxation-based BT compared to CT or CBT, based on studies showing that people with personality features associated with a need for autonomy respond best to treatments that are more experiential, concrete, and self-directed compared to therapies involving abstract analysis of one’s problems (e.g., containing CT). Method This was a secondary analysis of Borkovec, Newman, Pincus, and Lytle (2002). Forty-seven participants with principal diagnoses of GAD were assigned randomly to combined CBT (n = 16), CT (n = 15), or BT (n = 16). Results As predicted, compared to participants with less intrusiveness, those with dimensionally more intrusiveness responded with greater GAD symptom reduction to BT than to CBT at posttreatment and greater change to BT than to CT or CBT across all follow-up points. Similarly, those with more dominance responded better to BT compared to CT and CBT at all follow-up points. Additionally, being overly nurturant at baseline was associated with GAD symptoms at baseline, post, and all follow-up time-points regardless of therapy condition. Conclusions Generally anxious individuals with domineering and intrusive problems associated with higher need for control may respond better to experiential behavioral interventions than to cognitive interventions, which may be perceived as a direct challenge of their perceptions. PMID:28077221

  8. Interpersonal Problems Predict Differential Response to Cognitive Versus Behavioral Treatment in a Randomized Controlled Trial.

    PubMed

    Newman, Michelle G; Jacobson, Nicholas C; Erickson, Thane M; Fisher, Aaron J

    2017-01-01

    We examined dimensional interpersonal problems as moderators of cognitive behavioral therapy (CBT) versus its components (cognitive therapy [CT] and behavioral therapy [BT]). We predicted that people with generalized anxiety disorder (GAD) whose interpersonal problems reflected more dominance and intrusiveness would respond best to a relaxation-based BT compared to CT or CBT, based on studies showing that people with personality features associated with a need for autonomy respond best to treatments that are more experiential, concrete, and self-directed compared to therapies involving abstract analysis of one's problems (e.g., containing CT). This was a secondary analysis of Borkovec, Newman, Pincus, and Lytle (2002). Forty-seven participants with principal diagnoses of GAD were assigned randomly to combined CBT (n = 16), CT (n = 15), or BT (n = 16). As predicted, compared to participants with less intrusiveness, those with dimensionally more intrusiveness responded with greater GAD symptom reduction to BT than to CBT at posttreatment and greater change to BT than to CT or CBT across all follow-up points. Similarly, those with more dominance responded better to BT compared to CT and CBT at all follow-up points. Additionally, being overly nurturant at baseline was associated with GAD symptoms at baseline, post, and all follow-up time-points regardless of therapy condition. Generally anxious individuals with domineering and intrusive problems associated with higher need for control may respond better to experiential behavioral interventions than to cognitive interventions, which may be perceived as a direct challenge of their perceptions. Copyright © 2016. Published by Elsevier Ltd.

  9. Monte Carlo treatment planning for molecular targeted radiotherapy within the MINERVA system

    NASA Astrophysics Data System (ADS)

    Lehmann, Joerg; Hartmann Siantar, Christine; Wessol, Daniel E.; Wemple, Charles A.; Nigg, David; Cogliati, Josh; Daly, Tom; Descalle, Marie-Anne; Flickinger, Terry; Pletcher, David; DeNardo, Gerald

    2005-03-01

    The aim of this project is to extend accurate and patient-specific treatment planning to new treatment modalities, such as molecular targeted radiation therapy, incorporating previously crafted and proven Monte Carlo and deterministic computation methods. A flexible software environment is being created that allows planning radiation treatment for these new modalities and combining different forms of radiation treatment with consideration of biological effects. The system uses common input interfaces, medical image sets for definition of patient geometry and dose reporting protocols. Previously, the Idaho National Engineering and Environmental Laboratory (INEEL), Montana State University (MSU) and Lawrence Livermore National Laboratory (LLNL) had accrued experience in the development and application of Monte Carlo based, three-dimensional, computational dosimetry and treatment planning tools for radiotherapy in several specialized areas. In particular, INEEL and MSU have developed computational dosimetry systems for neutron radiotherapy and neutron capture therapy, while LLNL has developed the PEREGRINE computational system for external beam photon-electron therapy. Building on that experience, the INEEL and MSU are developing the MINERVA (modality inclusive environment for radiotherapeutic variable analysis) software system as a general framework for computational dosimetry and treatment planning for a variety of emerging forms of radiotherapy. In collaboration with this development, LLNL has extended its PEREGRINE code to accommodate internal sources for molecular targeted radiotherapy (MTR), and has interfaced it with the plugin architecture of MINERVA. Results from the extended PEREGRINE code have been compared to published data from other codes, and found to be in general agreement (EGS4—2%, MCNP—10%) (Descalle et al 2003 Cancer Biother. Radiopharm. 18 71-9). The code is currently being benchmarked against experimental data. The interpatient variability of the drug pharmacokinetics in MTR can only be properly accounted for by image-based, patient-specific treatment planning, as has been common in external beam radiation therapy for many years. MINERVA offers 3D Monte Carlo-based MTR treatment planning as its first integrated operational capability. The new MINERVA system will ultimately incorporate capabilities for a comprehensive list of radiation therapies. In progress are modules for external beam photon-electron therapy and boron neutron capture therapy (BNCT). Brachytherapy and proton therapy are planned. Through the open application programming interface (API), other groups can add their own modules and share them with the community.

  10. Side Effects of Long-Term Continuous Intra-arterial Nimodipine Infusion in Patients with Severe Refractory Cerebral Vasospasm after Subarachnoid Hemorrhage.

    PubMed

    Kieninger, Martin; Flessa, Julia; Lindenberg, Nicole; Bele, Sylvia; Redel, Andreas; Schneiker, André; Schuierer, Gerhard; Wendl, Christina; Graf, Bernhard; Silbereisen, Vera

    2018-02-01

    Long-term continuous intra-arterial nimodipine infusion (CIAN) is a rescue therapy option in cases of severe refractory cerebral vasospasm (CV) following acute non-traumatic subarachnoid hemorrhage (SAH). However, CIAN therapy can be associated with relevant side effects. Available studies focus on intracerebral complications, whereas extracerebral side effects are rarely examined. Aim of the present study was to generate descriptive data on the clinical course during CIAN therapy and expectable extracerebral side effects. All patients treated with CIAN therapy for at least 5 days between May 2011 and December 2015 were included. We retrospectively extracted data from the patient data management system regarding the period between 2 days before the beginning and 5 days after the termination of CIAN therapy to analyze the course of ventilation parameters and pulmonary gas exchange, hemodynamic support, renal and liver function, integrity of the gastrointestinal tract, and the occurrence of infectious complications. In addition, we recorded the mean daily values of intracranial pressure (ICP) and intracerebral problems associated with CIAN therapy. Data from 28 patients meeting inclusion criteria were analyzed. The mean duration of long-term CIAN therapy was 10.5 ± 4.5 days. Seventeen patients (60.7%) reached a good outcome level (Glasgow Outcome Scale [GOS] 4-5) 6 months after SAH. An impairment of the pulmonary gas exchange occurred only at the very beginning of CIAN therapy. The required vasopressor support with norepinephrine was significantly higher on all days during and the first day after CIAN therapy compared to the situation before starting CIAN therapy. Two patients required short-time resuscitation due to cardiac arrest during CIAN therapy. Acute kidney injury was observed in four patients, and one of them required renal replacement therapy with sustained low-efficiency daily dialysis. During CIAN therapy, 23 patients (82.1%) needed the escalation of a previous antiinfective therapy or the onset of antibiotics which was in line with a significant increase of C-reactive protein and white blood cell count. Obstipation was observed in 22 patients (78.6%). Ten patients (35.7%) even showed insufficient defecation on at least seven consecutive days. Compared to the situation before, ICP was significantly higher during the whole period of CIAN therapy. Long-term CIAN therapy is associated with diverse side effects. The leading problems are an impairment of the hemodynamic situation and cardiac problems, an increase in infectious complications, a worsening of the motility of the gastrointestinal tract, and rising ICP values. Teams on neurointensive care units must be aware of these side effects to avoid that the beneficial effects of CIAN therapy on CV reported elsewhere are foiled by the problems this technique can be associated with.

  11. Piaget and psychotherapy.

    PubMed

    Friedman, T L

    1978-04-01

    It is difficult to apply Piaget's theory to psychotherapy because the place of affect in it is ambiguous. When the alternatives are considered, it seems most consistent with Piaget's ideas to regard both cognitive and affective phenomena as problem-solving organizations. Piaget's remarkable discoveries in the cognitive sphere are a consequence of the easy access in that sphere to the kind of problems that need solving, and the phasic development of solutions. But the nature of the problems to be solved or the values to be guarded by a patient in psychotherapy are not knowable independently of the patient's actual behavior. In one respect all that is left from Piaget's approach for psychotherapy generally is the truism that therapy fosters differentiation and integration. However, even if we cannot frame a peculiarly Piagetian paradigm of psychotherapy, Piaget is valuable in posing a subsidiary question, namely, what in therapy fosters problem-solving activity. A reading of Piaget suggests that a patient learns by acting on his therapist and tacitly interpreting the results of his actions, that difficulties in therapy are the material from which therapy proceeds, and that in order to grasp the situation of the patient, the therapist himself may need to act on him and not just think about him. An implied lesson for training would be that supervision should instill a professional identity that is reinforced rather than challenged by therapy difficulties, and does not rely solely on theoretical categorizing.

  12. Privacy-preserving screen capture: towards closing the loop for health IT usability.

    PubMed

    Cooley, Joseph; Smith, Sean

    2013-08-01

    As information technology permeates healthcare (particularly provider-facing systems), maximizing system effectiveness requires the ability to document and analyze tricky or troublesome usage scenarios. However, real-world health IT systems are typically replete with privacy-sensitive data regarding patients, diagnoses, clinicians, and EMR user interface details; instrumentation for screen capture (capturing and recording the scenario depicted on the screen) needs to respect these privacy constraints. Furthermore, real-world health IT systems are typically composed of modules from many sources, mission-critical and often closed-source; any instrumentation for screen capture can rely neither on access to structured output nor access to software internals. In this paper, we present a tool to help solve this problem: a system that combines keyboard video mouse (KVM) capture with automatic text redaction (and interactively selectable unredaction) to produce precise technical content that can enrich stakeholder communications and improve end-user influence on system evolution. KVM-based capture makes our system both application-independent and OS-independent because it eliminates software-interface dependencies on capture targets. Using a corpus of EMR screenshots, we present empirical measurements of redaction effectiveness and processing latency to demonstrate system performances. We discuss how these techniques can translate into instrumentation systems that improve real-world health IT deployments. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. The Application of Acceptance and Commitment Therapy to Problem Anger

    ERIC Educational Resources Information Center

    Eifert, Georg H.; Forsyth, John P.

    2011-01-01

    The goal of this paper is to familiarize clinicians with the use of Acceptance and Commitment Therapy (ACT) for problem anger by describing the application of ACT to a case of a 45-year-old man struggling with anger. ACT is an approach and set of intervention technologies that support acceptance and mindfulness processes linked with commitment and…

  14. Students' Problem Solving as Mediated by Their Cognitive Tool Use: A Study of Tool Use Patterns

    ERIC Educational Resources Information Center

    Liu, M.; Horton, L. R.; Corliss, S. B.; Svinicki, M. D.; Bogard, T.; Kim, J.; Chang, M.

    2009-01-01

    The purpose of this study was to use multiple data sources, both objective and subjective, to capture students' thinking processes as they were engaged in problem solving, examine the cognitive tool use patterns, and understand what tools were used and why they were used. The findings of this study confirmed previous research and provided clear…

  15. 40 CFR 63.4567 - How do I establish the emission capture system and add-on control device operating limits during...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Hazardous Air Pollutants for Surface Coating of Plastic Parts and Products Compliance Requirements for the... procedures. If problems are found during the catalyst activity test, you must replace the catalyst bed or... inspection of the catalytic oxidizer system, including the burner assembly and fuel supply lines for problems...

  16. 40 CFR 63.4567 - How do I establish the emission capture system and add-on control device operating limits during...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Hazardous Air Pollutants for Surface Coating of Plastic Parts and Products Compliance Requirements for the... procedures. If problems are found during the catalyst activity test, you must replace the catalyst bed or... inspection of the catalytic oxidizer system, including the burner assembly and fuel supply lines for problems...

  17. How Levels of Interactivity in Tutorials Affect Students' Learning of Modeling Transportation Problems in a Spreadsheet

    ERIC Educational Resources Information Center

    Seal, Kala Chand; Przasnyski, Zbigniew H.; Leon, Linda A.

    2010-01-01

    Do students learn to model OR/MS problems better by using computer-based interactive tutorials and, if so, does increased interactivity in the tutorials lead to better learning? In order to determine the effect of different levels of interactivity on student learning, we used screen capture technology to design interactive support materials for…

  18. New Directions in Evaluating Social Problem Solving in Childhood: Early Precursors and Links to Adolescent Social Competence

    ERIC Educational Resources Information Center

    Landry, Susan H.; Smith, Karen E.; Swank, Paul R.

    2009-01-01

    A major objective of this chapter is to present a novel, ecologically sensitive social problem-solving task for school-aged children that captures the complexity of social and cognitive demands placed on children in naturalistic situations. Competence on this task correlates with a range of skills including executive functions, verbal reasoning,…

  19. War and Peace in Literature. Prose, Drama and Poetry Which Illuminate the Problem of War.

    ERIC Educational Resources Information Center

    Dougall, Lucy, Comp.

    Literary works that will help teachers of humanities and conflict resolution courses lead their students to a better understanding of the problems of war and peace are summarized. The document is based on two premises: (1) literature that captures the experience and the meaning of war leads to an understanding of that phenomenon, and (2) the…

  20. Exercise Sensing and Pose Recovery Inference Tool (ESPRIT) - A Compact Stereo-based Motion Capture Solution For Exercise Monitoring

    NASA Technical Reports Server (NTRS)

    Lee, Mun Wai

    2015-01-01

    Crew exercise is important during long-duration space flight not only for maintaining health and fitness but also for preventing adverse health problems, such as losses in muscle strength and bone density. Monitoring crew exercise via motion capture and kinematic analysis aids understanding of the effects of microgravity on exercise and helps ensure that exercise prescriptions are effective. Intelligent Automation, Inc., has developed ESPRIT to monitor exercise activities, detect body markers, extract image features, and recover three-dimensional (3D) kinematic body poses. The system relies on prior knowledge and modeling of the human body and on advanced statistical inference techniques to achieve robust and accurate motion capture. In Phase I, the company demonstrated motion capture of several exercises, including walking, curling, and dead lifting. Phase II efforts focused on enhancing algorithms and delivering an ESPRIT prototype for testing and demonstration.

  1. A Reversed Photosynthesis-like Process for Light-Triggered CO2 Capture, Release, and Conversion.

    PubMed

    Wang, Dingguan; Liao, Shenglong; Zhang, Shiming; Wang, Yapei

    2017-06-22

    Materials for CO 2 capture have been extensively exploited for climate governance and gas separation. However, their regeneration is facing the problems of high energy cost and secondary CO 2 contamination. Herein, a reversed photosynthesis-like process is proposed, in which CO 2 is absorbed in darkness while being released under light illumination. The process is likely supplementary to natural photosynthesis of plants, in which, on the contrary, CO 2 is released during the night. Remarkably, the material used here is able to capture 9.6 wt.% CO 2 according to its active component. Repeatable CO 2 capture at room temperature and release under light irradiation ensures its convenient and cost-effective regeneration. Furthermore, CO 2 released from the system is successfully converted into a stable compound in tandem with specific catalysts. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. The Isolation of Pure Populations of Neurons by Laser Capture Microdissection: Methods and Application in Neuroscience.

    PubMed

    Morris, Renée; Mehta, Prachi

    2018-01-01

    In mammals, the central nervous system (CNS) is constituted of various cellular elements, posing a challenge to isolating specific cell types to investigate their expression profile. As a result, tissue homogenization is not amenable to analyses of motor neurons profiling as these represent less than 10% of the total spinal cord cell population. One way to tackle the problem of tissue heterogeneity and obtain meaningful genomic, proteomic, and transcriptomic profiling is to use laser capture microdissection technology (LCM). In this chapter, we describe protocols for the capture of isolated populations of motor neurons from spinal cord tissue sections and for downstream transcriptomic analysis of motor neurons with RT-PCR. We have also included a protocol for the immunological confirmation that the captured neurons are indeed motor neurons. Although focused on spinal cord motor neurons, these protocols can be easily optimized for the isolation of any CNS neurons.

  3. Light-Triggered CO2 Breathing Foam via Nonsurfactant High Internal Phase Emulsion.

    PubMed

    Zhang, Shiming; Wang, Dingguan; Pan, Qianhao; Gui, Qinyuan; Liao, Shenglong; Wang, Yapei

    2017-10-04

    Solid materials for CO 2 capture and storage have attracted enormous attention for gaseous separation, environmental protection, and climate governance. However, their preparation and recovery meet the problems of high energy and financial cost. Herein, a controllable CO 2 capture and storage process is accomplished in an emulsion-templated polymer foam, in which CO 2 is breathed-in under dark and breathed-out under light illumination. Such a process is likely to become a relay of natural CO 2 capture by plants that on the contrary breathe out CO 2 at night. Recyclable CO 2 capture at room temperature and release under light irradiation guarantee its convenient and cost-effective regeneration in industry. Furthermore, CO 2 mixed with CH 4 is successfully separated through this reversible breathing in and out system, which offers great promise for CO 2 enrichment and practical methane purification.

  4. Automatic human body modeling for vision-based motion capture system using B-spline parameterization of the silhouette

    NASA Astrophysics Data System (ADS)

    Jaume-i-Capó, Antoni; Varona, Javier; González-Hidalgo, Manuel; Mas, Ramon; Perales, Francisco J.

    2012-02-01

    Human motion capture has a wide variety of applications, and in vision-based motion capture systems a major issue is the human body model and its initialization. We present a computer vision algorithm for building a human body model skeleton in an automatic way. The algorithm is based on the analysis of the human shape. We decompose the body into its main parts by computing the curvature of a B-spline parameterization of the human contour. This algorithm has been applied in a context where the user is standing in front of a camera stereo pair. The process is completed after the user assumes a predefined initial posture so as to identify the main joints and construct the human model. Using this model, the initialization problem of a vision-based markerless motion capture system of the human body is solved.

  5. Drug-related problems and pharmacist interventions in a cohort of patients with asthma and chronic obstructive pulmonary disease.

    PubMed

    Apikoglu-Rabus, Sule; Yesilyaprak, Gozde; Izzettin, Fikret Vehbi

    2016-11-01

    Asthma and chronic obstructive pulmonary disease are preventable and treatable chronic airway diseases with high incidence and prevalence. Pharmacists and clinical pharmacy based pharmaceutical care services have positive impact on therapy outcomes. The aim of this study is to describe drug related problems in a cohort of patients with asthma and chronic obstructive pulmonary disease and to assess interventions provided by the pharmacist to address these problems in a community pharmacy. Study population consisted of patients with asthma and chronic obstructive pulmonary disease older than 18 years who visited the study pharmacy during the pre-determined six-month period. The patients whose disease control states were "not fully controlled" were included in our study for further steps. On the first interview, present and potential drug related problems were addressed, interventions were provided. Follow-up interviews were held one month and two months later than the first interview. For the 44 patients with asthma, 59 drug-related problems and 134 causes for these problems were identified. Eighty-four interventions were made to resolve the problems; and 54.2% of the problems were resolved. For the 37 patients with chronic obstructive pulmonary disease, 60 drug-related problems and 128 causes for these problems were identified. Ninety-five interventions were made to resolve the problems; and 63.3% of the problems were resolved. Pharmacists taking part in therapy and management of asthma and chronic obstructive pulmonary disease can help patients be more educated about their disease and medications; and improve disease control and therapy outcomes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Massage therapy research review

    PubMed Central

    Field, Tiffany

    2017-01-01

    In this review, massage therapy has been shown to have beneficial effects on varying conditions including prenatal depression, preterm infants, full-term infants, autism, skin conditions, pain syndromes including arthritis and fibromyalgia, hypertension, autoimmune conditions including asthma and multiple sclerosis, immune conditions including HIV and breast cancer and aging problems including Parkinson's and dementia. Although many of the studies have involved comparisons between massage therapy and standard treatment control groups, several have compared different forms of massage (e.g. Swedish versus Thai massage), and different active therapies such as massage versus exercise. Typically, the massage therapy groups have experienced more positive effects than the control or comparison groups. This may relate to the massage therapy providing more stimulation of pressure receptors, in turn enhancing vagal activity and reducing Cortisol levels. Some of the researchers have assessed physical, physiological and biochemical effects, although most have relied exclusively on self-report measures. Despite these methodological problems and the dearth of research from the U.S., the massage therapy profession has grown significantly and massage therapy is increasingly practiced in traditional medical settings, highlighting the need for more rigorous research. PMID:27502797

  7. Massage therapy research review.

    PubMed

    Field, Tiffany

    2016-08-01

    In this review, massage therapy has been shown to have beneficial effects on varying conditions including prenatal depression, preterm infants, full-term infants, autism, skin conditions, pain syndromes including arthritis and fibromyalgia, hypertension, autoimmune conditions including asthma and multiple sclerosis, immune conditions including HIV and breast cancer and aging problems including Parkinson's and dementia. Although many of the studies have involved comparisons between massage therapy and standard treatment control groups, several have compared different forms of massage (e.g. Swedish versus Thai massage), and different active therapies such as massage versus exercise. Typically, the massage therapy groups have experienced more positive effects than the control or comparison groups. This may relate to the massage therapy providing more stimulation of pressure receptors, in turn enhancing vagal activity and reducing cortisol levels. Some of the researchers have assessed physical, physiological and biochemical effects, although most have relied exclusively on self-report measures. Despite these methodological problems and the dearth of research from the U.S., the massage therapy profession has grown significantly and massage therapy is increasingly practiced in traditional medical settings, highlighting the need for more rigorous research. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Orthodontics for the dog. Treatment methods.

    PubMed

    Ross, D L

    1986-09-01

    This article considers the prevention of orthodontic problems, occlusal adjustments, simple tooth movements, rotational techniques, tipping problems, adjustment of crown height, descriptions of common orthodontic appliances, and problems associated with therapy.

  9. A Conceptual Framework for Predicting Error in Complex Human-Machine Environments

    NASA Technical Reports Server (NTRS)

    Freed, Michael; Remington, Roger; Null, Cynthia H. (Technical Monitor)

    1998-01-01

    We present a Goals, Operators, Methods, and Selection Rules-Model Human Processor (GOMS-MHP) style model-based approach to the problem of predicting human habit capture errors. Habit captures occur when the model fails to allocate limited cognitive resources to retrieve task-relevant information from memory. Lacking the unretrieved information, decision mechanisms act in accordance with implicit default assumptions, resulting in error when relied upon assumptions prove incorrect. The model helps interface designers identify situations in which such failures are especially likely.

  10. Computational cameras for moving iris recognition

    NASA Astrophysics Data System (ADS)

    McCloskey, Scott; Venkatesha, Sharath

    2015-05-01

    Iris-based biometric identification is increasingly used for facility access and other security applications. Like all methods that exploit visual information, however, iris systems are limited by the quality of captured images. Optical defocus due to a small depth of field (DOF) is one such challenge, as is the acquisition of sharply-focused iris images from subjects in motion. This manuscript describes the application of computational motion-deblurring cameras to the problem of moving iris capture, from the underlying theory to system considerations and performance data.

  11. Effects of heat conduction on artificial viscosity methods for shock capturing

    DOE PAGES

    Cook, Andrew W.

    2013-12-01

    Here we investigate the efficacy of artificial thermal conductivity for shock capturing. The conductivity model is derived from artificial bulk and shear viscosities, such that stagnation enthalpy remains constant across shocks. By thus fixing the Prandtl number, more physical shock profiles are obtained, only on a larger scale. The conductivity model does not contain any empirical constants. It increases the net dissipation of a computational algorithm but is found to better preserve symmetry and produce more robust solutions for strong-shock problems.

  12. How does routinely delivered cognitive-behavioural therapy for gambling disorder compare to "gold standard" clinical trial?

    PubMed

    Smith, David P; Fairweather-Schmidt, A Kate; Harvey, Peter W; Battersby, Malcolm W

    2018-03-01

    Currently, it is unknown whether treatment outcomes derived from randomized controlled trials (RCTs) of cognitive-behavioural therapy (CBT) for problem gamblers still hold when applied to patients seen in routine practice. Thus, data from an RCT of cognitive therapy versus exposure therapy for problem gambling versus patients of a gambling help service were compared. Assessments of problem gambling severity, psychosocial impairment, and alcohol use were undertaken at baseline and post-treatment and evaluated within a counterfactual framework. Findings showed that the contrast between routine CBT for pokies and horse betting had a significant effect, indicative of a 62% lower gambling urge score if routine CBT recipients had all been horse/track betters opposed to gambling with "pokies." However, the majority of contrasts indicated therapeutic outcomes achieved in routine CBT treatments were of equivalent robustness relative to RCT conditions. The present findings infer routine practice treatment outcomes are as efficacious as those generated in RCT contexts. Copyright © 2017 John Wiley & Sons, Ltd.

  13. The development of PROQOL-HIV: an international instrument to assess the health-related quality of life of persons living with HIV/AIDS.

    PubMed

    Duracinsky, Martin; Herrmann, Susan; Berzins, Baiba; Armstrong, Andrew R; Kohli, Rewa; Le Coeur, Sophie; Diouf, Assane; Fournier, Isabelle; Schechter, Mauro; Chassany, Olivier

    2012-04-15

    Health-related quality of life (HRQL) is an important outcome in HIV/AIDS infection and treatment. However, most existing HIV-HRQL instruments miss important issues (eg, sleeping problems, lipodystrophy). They were developed before highly active antiretroviral therapy (pre-HAART), and in a single language. We sought to develop a contemporary HIV-HRQL instrument (PROQOL-HIV) in multiple languages that accounts for HAART treatment and side effects. This article details the 3-stage content validation phase of PROQOL-HIV. In stage 1, we developed a conceptual model of HIV-HRQL and questionnaire item bank from thematic analysis of 152 patient interviews conducted simultaneously across 9 countries. In stage 2, pilot items were selected by an expert panel to form the pilot instrument. Stage 3 involved linguistic validation and harmonization of selected items to form an equivalent instrument in 9 target languages. Analysis of 3375 pages of interview text revealed 11 underlying themes: general health perception, social relationships, emotions, energy/fatigue, sleep, cognitive functioning, physical and daily activity, coping, future, symptoms, and treatment. Seven issues new to HIV-HRQL measurement were subsumed by these themes: infection fears, future concerns, satisfaction with care, self-esteem problems, sleep problems, work disruption, and treatment issues. Of the 442 theme-related items banked, 70 items met the retention criteria and formed the pilot PROQOL-HIV instrument. HIV patients across 11 countries attributed a wide range of physical, mental, and social issues to their condition, many of which were not measured by existing HIV-HRQL instruments. The pilot PROQOL-HIV instrument captures these issues, is sensitive to sociocultural context, disease stage, and HAART.

  14. A Noninferiority Trial of a Problem-Solving Intervention for Hospice Caregivers: In Person versus Videophone

    PubMed Central

    Parker Oliver, Debra; Wittenberg-Lyles, Elaine; Washington, Karla; Doorenbos, Ardith; Rue, Tessa; Berry, Donna

    2012-01-01

    Abstract Purpose of the study Problem-solving therapy (PST) has been found effective when delivered to informal caregivers of patients with various conditions. In hospice, however, its translation to practice is impeded by the increased resources needed for its delivery. The study purpose was to compare the effectiveness of a PST intervention delivered face-to-face with one delivered via videophone to hospice primary caregivers. Design and methods The study design was a randomized noninferiority trial with two groups, Group 1 in which caregivers received PST face-to-face, and Group 2 in which caregivers received PST via videophone. Family hospice caregivers were recruited from two urban hospice agencies and received the PST intervention (in three visits for Group 1 or three video-calls in Group 2) in an approximate period of 20 days after hospice admission. Standard caregiver demographic data were collected. Psychometric instruments administered to caregivers at baseline and at study completion included the CQLI-R (Caregiver Quality of Life Index–Revised), the STAI (State-Trait Anxiety Inventory), and the PSI (Problem-Solving Inventory). Results One hundred twenty-six caregivers were recruited in the study; 77 were randomly assigned to Group 1 and 49 to Group 2. PST delivered via video was not inferior to face-to-face delivery. The observed changes in scores were similar for each group. Caregiver quality of life improved and state anxiety decreased under both conditions. Conclusions The delivery of PST via videophone was not inferior to face-to-face. Audiovisual feedback captured by technology may be sufficient, providing a solution to the geographic barriers that often inhibit the delivery of these types of interventions to older adults in hospice. PMID:22536989

  15. A Virtual Patient Software Program to Improve Pharmacy Student Learning in a Comprehensive Disease Management Course

    PubMed Central

    Casale, Jillian P.; Skirvin, J. Andrew; DiVall, Margarita V.

    2013-01-01

    Objective. To implement and assess the impact of a virtual patient pilot program on pharmacy students’ clinical competence skills. Design. Pharmacy students completed interactive software-based patient case scenarios embedded with drug-therapy problems as part of a course requirement at the end of their third year. Assessment. Assessments included drug-therapy problem competency achievement, performance on a pretest and posttest, and pilot evaluation survey instrument. Significant improvements in students’ posttest scores demonstrated advancement of clinical skills involving drug-therapy problem solving. Students agreed that completing the pilot program improved their chronic disease management skills and the program summarized the course series well. Conclusion. Using virtual patient technology allowed for assessment of student competencies and improved learning outcomes. PMID:24159213

  16. Cognitive-behavioral therapy and hypnotic relaxation to treat sleep problems in an adolescent with diabetes.

    PubMed

    Perfect, Michelle M; Elkins, Gary R

    2010-11-01

    Inadequate sleep among adolescents frequently contributes to obesity and reduced academic performance, along with symptoms of anxiety, depression, fatigue, and attention deficits. The etiological bases of sleep quality has been associated with both stress and sleep habits. These problems tend to be especially important for adolescents with diabetes as the effects of poor sleep complicate health outcomes. This case example concerns a 14-year-old adolescent girl with a history of type I diabetes and stress-related sleep difficulties. Treatment included cognitive-behavioral methods and hypnotic relaxation therapy. Results of this case example and other controlled research suggest that hypnotic relaxation therapy is well accepted, results in good compliance, and serves as a useful adjunctive to cognitive-behavioral intervention for sleep problems. © 2010 Wiley Periodicals, Inc.

  17. Viscous constraints on predator:food size ratios in microscale feeding

    NASA Astrophysics Data System (ADS)

    Jabbarzadeh, Mehdi; Fu, Henry

    2014-11-01

    Small organisms such as protists or copepods may try to capture food by manipulating food with cilia, limbs, or feeding appendages. At these small scales, viscous flow may complicate the ability of a feeding appendage to closely approach a food particle. As a simplified but tractable model of such feeding approach, we consider the problem of two spheres approaching in a Stokes fluid. The first ``feeding'' sphere, which represents a body part or feeding appendage, is pushed with a constant force towards a force-free ``food'' sphere. When the feeding sphere reaches within a cutoff distance of the food sphere we assume that nonhydrodynamic interactions lead to capture. We examine approach for a range of size ratios between the feeding and food sphere. To investigate the approach efficiency, we examine the time required for the feeding sphere to capture the food sphere, as well as how far the feeding sphere must move before it captures the food sphere. We also examine the effect of varying the cutoff distance for capture. We find that hydrodynamic interactions strongly affect the results when the size of the spheres is comparable. We describe what relative sizes between feeding sphere and food particles may be most effective for food capture.

  18. INEL BNCT Program: Volume 5, No. 9. Bulletin, September 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ackermann, A.L.

    1991-12-31

    This Bulletin presents a summary of accomplishments and highlights of the Idaho National Engineering Laboratory`s (INEL) Boron Neutron Capture Therapy (BNCT) Program for September 1991. This bulletin includes information on the brain tumor and melanoma research programs, Power Burst Facility (PBF) technical support and modifications, PBF operations, and updates to the animal data charts.

  19. Farm Tractors, Occupational Therapy, and Four-Wheel Drive: Transforming a Military Vehicle into a Cultural Icon

    ERIC Educational Resources Information Center

    Iarocci, Andrew

    2010-01-01

    The armed forces of World War II employed unprecedented numbers of mechanical transport vehicles, precipitating a spike in demand for automotive manufactures. Eager to capture a share of the less certain postwar automobile marketplace, defense contractors such as Willys-Overland pursued a diverse range of product development and advertising…

  20. [Mediative behavior therapy in complex behavioral problems. Illustrative cases from a psychogeriatric nursing home].

    PubMed

    Geelen, R; Bleijenberg, G

    1999-04-01

    An application in a psychogeriatric nursing home. This article describes the application of mediative behaviour therapy in a psychogeriatric nursing home. Behavioural interventions carried out by the nursing team addressed a variety of problems: quarreling between an institutionalised woman and her visiting husband, complaining about this staff by the husband to team members of another department, and the patient who let herself drop on the floor about once a week. Special regard is given to the analysis of the problems, the learning of appropriate responses by team members, as well as changing their cognitions and emotions about the problem behaviours. A meaningful reduction of the problem behaviours and of the burden experienced by team members was achieved.

Top