Effect of four different opalescence tooth-whitening products on enamel microhardness.
Majeed, A; Grobler, S R; Moola, M H; Rossouw, R J; van Kotze, T J W
2008-06-01
The purpose was to evaluate the effect of various Opalescence tooth-whitening products on enamel. Enamel blocks were exposed to Opalescence PF 10% Carbamide Peroxide (n = 10), Opalescence PF 20% Carbamide Peroxide (n = 10), Opalescence Trèswhite Supreme 10% Hydrogen Peroxide (n = 10) and Opalescence Quick PF 45% Carbamide Peroxide (n = 10) according to the manufacturer's instructions. The control group was enamel blocks (n = 10) kept in artificial saliva. The values were obtained before exposure and after the 14-days treatment period. Enamel blocks were kept in saliva between treatments. Indent marks on enamel blocks were examined using the scanning electron microscope for treatment effects. All four different Opalescence products damaged enamel. The most damage was done when treated for a long period (112 hours). SEM images also showed damage to enamel by all 4 products. Opalescence with 10% and with 20% Carbamide Peroxide showed the highest damage, which also differed significantly (p < 0.05) from the saliva control group (p < 0.05; Tukey-Kramer Multiple comparison test). All 4 Opalescence products damaged enamel. Higher damage was done by the 10% carbamide peroxide and 20% carbamide peroxide products because of the much longer exposure period (112 hours in comparison to 7 hours).
Vahid Dastjerdi, Elahe; Khaloo, Negar; Mojahedi, Seyed Masoud; Azarsina, Mohadese
2015-11-01
Bleaching treatments decrease shear bond strength between orthodontic brackets and teeth; although definite results have not been reported in this regard. This study determined the effects of different bleaching protocols on the shear bond strength of orthodontic brackets to teeth. This experimental study was performed in Iran. Forty-eight extracted human premolars were randomly assigned into four groups. In the control group, no bleaching treatment was performed. In groups 2 - 4, the bleaching procedures were performed using carbamide peroxide 45%, carbamide peroxide 20% and diode laser, respectively. Two weeks later, brackets were bonded to teeth and thermocycled. The shear bond strengths of the brackets to the teeth were measured. Data was analyzed by one-way ANOVA and Dunnett post-hoc test. Shear bond strength of the brackets to the teeth were 10.54 ± 1.51, 6.37 ± 0.92, 7.67 ± 1.01 and 7.49 ± 1.19 MPa, in groups 1 - 4, respectively. Significant differences were found between control group and all other groups (P < 0.001); and also between groups 2 and 3 (P < 0.05). No significant differences were found between the other groups. The bleaching procedures using 20% carbamide peroxide and 45% carbamide peroxide and diode laser significantly decreased shear bond strength of brackets to the teeth. 45% carbamide peroxide had a more significant effect on bond strength compared to 20% carbamide peroxide. The difference in bond strength was not significant between laser group and either carbamide peroxide groups.
Badole, Gautam P; Warhadpande, Manjusha M; Bahadure, Rakesh N; Badole, Shital G
2013-01-01
Discolouration of teeth, especially the anteriores, can result in considerably cosmetic impairment in person. Combine effects of intrinsic and extrinsic colour determines the appearance of teeth. Whitening of teeth with bleaching is a more conservative therapeutic method than full crowns, veneers or composite restorations which is more invasive and expensive. Among bleaching techniques, in office bleaching with carbamide peroxide provide superior aesthetic result in short period of time with no adverse effects. This paper presents case series of tooth discolouration in non-vital tooth which was successfully bleached using 35 % carbamide peroxide. After 1 year follow up the prognosis was good with no reversal of tooth discolouration. This case report allows the better understanding of the concept of nonvital tooth bleaching with carbamide peroxide which gives a non-invasive alternative for aesthetic purpose in preserving the natural tooth structure. PMID:24551731
Nitrogen-containing superlow-carbon austenitic steel 02Kh25N22AM2
NASA Astrophysics Data System (ADS)
Fe'ldgandler, É. G.; Svistunova, T. V.; Savkina, L. Ya.; Lapshina, O. B.
1996-02-01
At present the equipment for manufacturing carbamide mineral fertilizers is produced from domestic steel 03Kh17N14M3 having "carbamide quality." Imported equipment also used in the industry is produced from steel of the 25-22-2 (Cr -Ni-Mo) type shipped by various firms, namely, 2RE69 (Sandvik, Sweden), 254SFER (Avesta, Sweden), 2522LCN (VDM, Germany), DM 1.4466 (Germany), and X2CrNiMo 25-22-2 (Dalmine, Italy). The imported steels are used because in some units steel 03Khl7Nl4M3 does not provide the requisite corrosion resistance in an intensified process of carbamide manufacturing. We currently possess domestic high-alloyed steel for producing new and repairing imported equipment operating under the severe conditions of carbamide synthesis. The present paper concerns the structure, mechanical properties, and corrosion resistance of industrially produced steel 02Kh25N22AM2 (ChS-108) and the recommended range of its application.
In vitro study on tooth enamel lesions related to whitening dentifrice.
de Araújo, Danilo Barral; Silva, Luciana Rodrigues; Campos, Elisângela de Jesus; Correia de Araújo, Roberto Paulo
2011-01-01
The tooth whitening substances for extrinsic use that are available in Brazil contain hydrogen peroxide or carbamide peroxide. Several studies have attributed the appearance of lesions in the enamel morphology, including hypersensitivity, to these substances. Such lesions justify fluoride therapy and application of infrared lasers, among other procedures. However, there is no consensus among researchers regarding the relevance of the severity of lesions detected on the tooth surface. The present study was carried out with an aim of evaluating in vitro the effects of the hydrogen peroxide, carbamide peroxide and sodium bicarbonate contained in dentifrice formulations, on human tooth enamel. After darkening process in laboratory, human premolars were brushed using dentifrice containing the two whitening substances (Rembrandt - carbamide peroxide and Mentadent - hydrogen peroxide) and the abrasive product (Colgate - sodium bicarbonate). The degree of specimen staining before and after this procedure was determined using spectrophotometry. Scanning electron microscopy (SEM) was used to obtain images, which were analyzed to show the nature of the lesions that appeared on the enamel surface. The effectiveness of the whitening caused by hydrogen peroxide and carbamide peroxide and the abrasion caused by bicarbonate were confirmed, given that the treated test pieces returned to their original coloration. Based on SEM, evaluation of the enamel surfaces subjected to the test products showed that different types of morphologic lesions of varying severity appeared. Whitening dentifrice containing hydrogen peroxide and carbamide peroxide produced lesions on the enamel surface such that the greatest sequelae were associated with exposure to hydrogen peroxide.
Araujo, Danilo Barral; Silva, Luciana Rodrigues; de Araujo, Roberto Paulo Correia
2010-01-01
Tooth whitening agents containing hydrogen peroxide and carbamide peroxide are used frequently in esthetic dental procedures. However, lesions on the enamel surface have been attributed to the action of these products. Using conventional procedures for separating and isolating biological structures, powdered enamel was obtained and treated with hydrogen peroxide, carbamide peroxide, and sodium bicarbonate, ingredients typically found in dentifrices. The enamel was exposed to different pH levels, and atomic emission spectrometry was used to determine calcium release rates. As the pH level increased, the rate of calcium release from enamel treated with dentifrices containing whitening agents decreased. Carbamide peroxide produced the lowest amount of decalcification, while sodium bicarbonate produced the highest release rates at all pH levels.
Kumar, A Ashok; Hariharavel, V P; Narayanan, Ashwin; Murali, S
2015-01-01
The aim of the study was to evaluate the microleakage on the marginal integrity of nanohybrid composite during bleaching with carbamide peroxide after applying a protective coating of G-Coat plus (GC, Japan). Class V cavities were prepared and restored with nanohybrid composite restoration in 60 freshly extracted noncarious premolars extracted for orthodontic reasons. Then they were divided into 3 groups. Group 1 - bleaching with carbamide peroxide without G coat plus (n = 20), Group 2 - bleaching with carbamide peroxide with G-Coat plus (n = 20), Group 3 - without bleaching procedure (n = 20) (control group). In Group 2, G coat plus was applied over the restorative surface and margins. Then all teeth in Groups 1 and 2 were taken and mounted in dental stone. Bleaching trays were custom fabricated over the cast with the help of a heated vacuum-forming machine. 10% carbamide peroxide (opalescence PF) was applied over the tooth, and the bleaching process was done for about 2 weeks. Then all samples underwent thermocycling and were then immersed in the 2% methylene blue solution for 24 h and observed under a stereomicroscope to evaluate the amount of dye penetration. Data were compared using Kruskal-Wallis test and Mann-Whitney test using SPSS Inc.; Chicago, IL, USA, Version 17.0. Mann-Whitney test shows that the difference in microleakage between Group 1-Group 2 and Group 2-Group 3 is statistically significant (P < 0.05). Significant reduction in microleakage was seen in Group 2 when compared to other groups.
A Study for Tooth Bleaching via Carbamide Peroxide-Loaded Hollow Calcium Phosphate Spheres.
Qin, Tao; Mellgren, Torbjörn; Jefferies, Steven; Xia, Wei; Engqvist, Håkan
2016-12-26
The objective of this study was to investigate if a prolonged bleaching effect of carbamide peroxide-loaded hollow calcium phosphate spheres (HCPS) can be achieved. HCPS was synthesized via a hydrothermal reaction method. Carbamide peroxide (CP) was-loaded into HCPS by mixing with distilled water as solvent. We developed two bleaching gels containing CP-loaded HCPS: one gel with low HP concentration as at-home bleaching gel, and one with high HP concentration as in-office gel. Their bleaching effects on stained human permanent posterior teeth were investigated by measuring the color difference before and after bleaching. The effect of gels on rhodamine B degradation was also studied. To investigate the potential effect of remineralization of using HCPS, bleached teeth were soaked in phosphate buffer solution (PBS) containing calcium and magnesium ions. Both bleaching gels had a prolonged whitening effect, and showed a strong ability to degrade rhodamine B. After soaking in PBS for 3 days, remineralization was observed at the sites where HCPS attached to the teeth surface. CP-loaded HCPS could prolong the HP release behavior and improve the bleaching effect. HCPS was effective in increasing the whitening effect of carbamide peroxide and improving remineralization after bleaching process.
Samiei, Mohammad; Janani, Maryam; Vahdati, Amin; Alemzadeh, Yalda; Bahari, Mahmoud
2017-01-01
The present study evaluated the element distribution in completely set calcium-enriched mixture (CEM) cement after application of 35% carbamide peroxide, 40% hydrogen peroxide and sodium perborate as commercial bleaching agents using an energy-dispersive x-ray microanalysis (EDX) system. The surface structure was also observed using the scanning electron microscope (SEM). Twenty completely set CEM cement samples, measuring 4×4 mm 2 , were prepared in the present in vitro study and randomly divided into 4 groups based on the preparation technique as follows: the control group; 35% carbamide peroxide group in contact for 30-60 min for 4 times; 40% hydrogen peroxide group with contact time of 15-20 min for 3 times; and sodium perborate group, where the powder and liquid were mixed and placed on CEM cement surface 4 times. Data were analyzed at a significance level of 0.05 through the one Way ANOVA and Tukey's post hoc tests. EDX showed similar element distribution of oxygen, sodium, calcium and carbon in CEM cement with the use of carbamide peroxide and hydroxide peroxide; however, the distribution of silicon was different ( P <0.05). In addition, these bleaching agents resulted in significantly higher levels of oxygen and carbon ( P <0.05) and a lower level of calcium ( P <0.05) compared to the control group. SEM of the control group showed plate-like and globular structure. Sodium perborate was similar to control group due to its weak oxidizing properties. Globular structures and numerous woodpecker holes were observed on the even surface on the carbamide peroxide group. The mean elemental distribution of completely set CEM cement was different when exposed to sodium perborate, carbamide peroxide and hydrogen peroxide.
Basting, R T; Rodrigues Júnior, A L; Serra, M C
2001-01-01
This in situ study evaluated the microhardness of sound and demineralized enamel and dentin submitted to treatment with 10% carbamide peroxide for three weeks. A 10% carbamide peroxide bleaching agent--Opalescence/Ultradent (OPA)--was evaluated against a placebo agent (PLA). Two hundred and forty dental fragments--60 sound enamel fragments (SE), 60 demineralized enamel fragments (DE), 60 sound dentin fragments (SD) and 60 demineralized dentin fragments (DD)--were randomly fixed on the vestibular surface of the first superior molars and second superior premolars of 30 volunteers. The volunteers were divided into two groups that received bleaching or the placebo agent at different sequences and periods at a double blind 2 x 2 crossover study with a wash-out period of two weeks. Microhardness tests were performed on the enamel and dentin surface. The SE and DE submitted to treatment with OPA showed lower microhardness values than the SE and DE submitted to treatment with PLA. There were no statistical differences in microhardness values for SD and DD submitted to the treatment with OPA and PLA. The results suggest that treatment with 10% carbamide peroxide bleaching material for three weeks alters the enamel microhardness, although it does not seem to alter the dentin microhardness.
Preparation and characterization of porous Mg-Zn-Ca alloy by space holder technique
NASA Astrophysics Data System (ADS)
Annur, D.; Lestari, Franciska P.; Erryani, A.; Sijabat, Fernando A.; G. P. Astawa, I. N.; Kartika, I.
2018-04-01
Magnesium had been recently researched as a future biodegradable implant material. In the recent study, porous Mg-Zn-Ca alloys were developed using space holder technique in powder metallurgy process. Carbamide (10-20%wt) was added into Mg-6Zn-1Ca (in wt%) alloy system as a space holder to create porous structure material. Sintering process was done in a tube furnace under Argon atmosphere in 610 °C for 5 hours. Porous structure of the resulted alloy was examined using Scanning Electron Microscope (SEM), while the phase formation was characterized by X-ray diffraction analysis (XRD). Further, mechanical properties of porous Mg-Zn-Ca alloy was examined through compression testing. Microstructure characterization showed higher content of Carbamide in the alloy would give different type of pores. However, compression test showed that mechanical properties of Mg-Zn-Ca alloy would decrease significantly when higher content of carbamide was added.
Carbamide peroxide whitening of nonvital single discolored teeth: case reports.
Caughman, W F; Frazier, K B; Haywood, V B
1999-03-01
Patients who present with a single discolored tooth represent a significant restorative challenge. These case reports describe an economic and conservative treatment option for these patients. The situations presented demonstrate techniques for bleaching with carbamide peroxide in a traditional nightguard or with an inside-outside technique to achieve acceptable esthetic results on isolated nonvital discolored teeth. Although these techniques may not be effective in all cases, they do not compromise or eliminate any future treatment options.
Penumatsa, Narendra Varma; Kaminedi, Raja Rajeswari; Baroudi, Kusai; Barakath, Ola
2015-01-01
Objective: The aim of this study was to evaluate the potential of casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) in remineralizing the bleached enamel surface using micro-hardness. Materials and Methods: Thirty human enamel slabs were randomly divided into three groups (n = 10). Groups A and B were exposed to 20% carbamide peroxide and 35% carbamide peroxide gel, respectively. After the exposure to the bleaching agent, the slabs were kept in artificial saliva for 1-week. Group C (control group) were kept in artificial saliva for 1-week. Vickers micro-hardness test was performed by Leica VMHT-Mot micro-hardness tester. CPP-ACP (Gc Tooth Mousse, Melbourne, Australia) was then applied to specimens of Groups A and B for 3 min for 2 weeks. Micro-hardness values of postbleach Group A (Ar) and Group B (Br) were recorded and statistically analyzed by paired t-test and one-way analysis of variance at the significance level of α =0.05. Results: There was a significant decrease in micro-hardness of enamel in carbamide peroxide bleached groups. However, there was a significant increase in micro-hardness after the remineralization by CPP-ACP and the extent of remineralization is more for the Group B. Conclusions: That bleaching agents reduced enamel micro-hardness and the use of CPP-ACP after bleaching can significantly enhance the micro-hardness of bleached enamel. PMID:26538923
Lu, Jing; Ding, Xiao-jun; Yu, Xiao-ping; Gong, Yi-ming
2015-10-01
To evaluate the effect of casein phosphopeptide-amorphouscalcium phosphate (CPP-ACP) treatment on the shear bond strength of orthodontic brackets after tooth bleaching. One hundred extracted human premolars were randomly divided and treated according to 5 groups (n=20) : (1) no treatment; (2) 10% carbamide peroxide bleaching; (3) 38% hydrogen peroxide bleaching; (4)10% carbamide peroxide bleaching and CPP-ACP paste; (5)38% hydrogen peroxide bleaching and CPP-ACP paste. In all groups, the brackets were bonded using a conventional acid-etch and bond system (Transbond XT, 3M Unitek, Monrovia, Calif). The shear bond strength adhesive remnant index (ARI) of the brackets were determined and the data was analyzed by ANOVA and Bonferroni test using SPSS13.0 software package. The use of 10% carbamide peroxide and 38% hydrogen peroxide bleaching significantly decreased the shear bond strength of orthodontic brackets when compared with untreated group (P<0.05). After combination of tooth bleaching and CPP-ACP treatment, group 4 (10% carbamide peroxide bleaching + CPP-ACP) and group 5 (38% hydrogen peroxide bleaching + CPP-ACP) showed higher levels of shear bond strength than group 2 and 3; however, no significant difference was found (P>0.05). The ARI did not show any significant difference before and after CPP-ACP treatment. After tooth bleaching, CPP-ACP treatment have little influence on the shear bond strength of orthodontic brackets.
Effect of Catalase and Sodium Fluoride on Human Enamel bleached with 35% Carbamide Peroxide.
Thakur, Ruchi; Shigli, Anand L; Sharma, Divya S; Thakur, Gagan
2015-01-01
To evaluate the effects of postbleaching antioxidant application fluoridation treatment on the surface morphology and microhardness of human enamel. Ten freshly extracted human maxillary central incisors were cut at cementoenamel junction. Crown portion was sectioned into six slabs which were divided into five groups: group A - untreated controls; group B - 35% carbamide peroxide (CP); group C - 35% CP and catalase; group D - treatment with 35% CP and 5% sodium fluoride; group E - 35% CP, catalase and 5% sodium fluoride. Thirty-five percent carbamide peroxide application included two applications of 30 minutes each at a 5-day interval. After treatment, the slabs were thoroughly washed with water for 10 seconds and stored in artificial saliva at 37°C until the next treatment. Two percent sodium fluoride included application for 5 minutes. Three catalase included application for 3 minutes. After 5 days, groups B and C showed significantly decreased enamel microhardness compared to control. Group D specimens showed relatively less reduction in enamel micro-hardness than group C specimens. There is a marked increase in enamel microhardness in group E specimens. Fluoride take up was comparatively enhanced after catalase application resulting in less demineralization and increased microhardness. How to cite this article: Thakur R, Shigli AL, Sharma DS, Thakur G. Effect of Catalase and Sodium Fluoride on Human Enamel bleached with 35% Carbamide Peroxide. Int J Clin Pediatr Dent 2015;8(1):12-17.
2018-01-01
Objectives The aim of this in vitro study was to evaluate the bond strength of 2 universal adhesives used in different application modes to bleached enamel. Materials and Methods Extracted 160 sound human incisors were used for the study. Teeth were divided into 4 treatment groups: No treatment, 35% hydrogen peroxide, 16% carbamid peroxide, 7.5% carbamid peroxide. After bleaching treatments, groups were divided into subgroups according to the adhesive systems used and application modes (n = 10): 1) Single Bond Universal, etch and rinse mode; 2) Single Bond Universal, self-etch mode; 3) Gluma Universal, etch and rinse mode; 4) Gluma Universal, self-etch mode. After adhesive procedures nanohybrid composite resin cylinders were bonded to the enamel surfaces. All specimens were subjected to shear bond strength (SBS) test after thermocycling. Data were analyzed using a 3-way analysis of variance (ANOVA) and Tukey post hoc test. Results No significant difference were found among bleaching groups (35% hydrogen peroxide, 16% carbamid peroxide, 7.5% carbamid peroxide, and no treatment groups) in the mean SBS values. There was also no difference in SBS values between Single Bond Universal and Gluma Universal at same application modes, whereas self-etch mode showed significantly lower SBS values than etch and rinse mode (p < 0.05). Conclusions The bonding performance of the universal adhesives was enhanced with the etch and rinse mode application to bleached enamel and non-bleached enamel. PMID:29765900
Effect of Catalase and Sodium Fluoride on Human Enamel bleached with 35% Carbamide Peroxide
Shigli, Anand L; Sharma, Divya S; Thakur, Gagan
2015-01-01
ABSTRACT Aim: To evaluate the effects of postbleaching antioxidant application fluoridation treatment on the surface morphology and microhardness of human enamel. Materials and methods: Ten freshly extracted human maxillary central incisors were cut at cementoenamel junction. Crown portion was sectioned into six slabs which were divided into five groups: group A – untreated controls; group B – 35% carbamide peroxide (CP); group C – 35% CP and catalase; group D – treatment with 35% CP and 5% sodium fluoride; group E – 35% CP, catalase and 5% sodium fluoride. Thirty-five percent carbamide peroxide application included two applications of 30 minutes each at a 5-day interval. After treatment, the slabs were thoroughly washed with water for 10 seconds and stored in artificial saliva at 37°C until the next treatment. Two percent sodium fluoride included application for 5 minutes. Three catalase included application for 3 minutes. Results: After 5 days, groups B and C showed significantly decreased enamel microhardness compared to control. Group D specimens showed relatively less reduction in enamel micro-hardness than group C specimens. There is a marked increase in enamel microhardness in group E specimens. Conclusions: Fluoride take up was comparatively enhanced after catalase application resulting in less demineralization and increased microhardness. How to cite this article: Thakur R, Shigli AL, Sharma DS, Thakur G. Effect of Catalase and Sodium Fluoride on Human Enamel bleached with 35% Carbamide Peroxide. Int J Clin Pediatr Dent 2015;8(1):12-17. PMID:26124575
NASA Astrophysics Data System (ADS)
Kamyshnaya, K. S.; Khabas, T. A.
2016-11-01
In this paper porous ceramics on the base of ZrO2 nanopowders and micropowders has been developed by freeze-casting method. A zirconia/carbamide slurry was frozen in mold and dehydrated in CaCl2 at room temperature. This simple process enabled the formation of porous ceramics with highly aligned pores as a replica of the carbamide crystals. The samples showed higher porosity of 47.9%. In addition, these materials could be used as membrane for air cleaning.
Influence of tooth bleaching on dental enamel microhardness: a systematic review and meta-analysis.
Zanolla, J; Marques, Abc; da Costa, D C; de Souza, A S; Coutinho, M
2017-09-01
Several studies have investigated the effect of bleaching on dental tissues. The evaluation of the effect of home bleaching with 10% carbamide peroxide is important for assessing alterations in enamel microhardness that may affect dental health in terms of resistance to masticatory forces. This meta-analysis was performed in order to determine scientific evidence regarding the effects of home vital bleaching with 10% carbamide peroxide gel on the microhardness of human dental enamel. A systematic electronic literature search was conducted in the PubMed and Web of Science databases using search terms. Two independent researchers evaluated the information and methodological quality of the studies. Inclusion and exclusion criteria were established for article selection; further, only studies published in English were selected. Thirteen studies that met all of the inclusion and exclusion criteria were selected and underwent statistical analysis. The results of this meta-analysis showed no significant changes in enamel microhardness when using the 10% carbamide peroxide bleaching gel over periods of 7, 14 and 21 days. © 2016 Australian Dental Association.
The effect of bleaching agents on the microhardness of dental aesthetic restorative materials.
Türker, S B; Biskin, T
2002-07-01
This study investigated the effects of three home bleaching agents on the microhardness of various dental aesthetic restorative materials. The restorative materials were: feldspatic porcelain, microfilled composite resin and light-cured modified glass-ionomer cement and the bleaching agents Nite-White (16% carbamide peroxide), Opalescence (10% carbamide peroxide and carbapol jel) and Rembrandt (10% carbamide peroxide jel). A total of 90 restorative material samples were prepared 1 cm diameter and 6 mm thick and kept in distilled water for 24 h before commencing bleaching which was carried out for 8 h day-1 for 4 weeks. Microhardness measurements were then made using a Tukon tester. Statistically significant differences with respect to unbleached controls were found only for the feldspatic porcelain and microfilled composite resins (P <0.05) for Nite-White and Opalescence. All the bleaching agents decreased the microhardness of the porcelain and increased that of the light cured modified glass-ionomer cement. For the composite resin, whereas Nite-White increased its microhardness, the other bleaching agents decreased it. There were no significant differences between the bleaching agents for any of the restorative materials.
High-performance supercapacitors using flexible and freestanding MnOx/carbamide carbon nanofibers
NASA Astrophysics Data System (ADS)
Samuel, Edmund; Jo, Hong Seok; Joshi, Bhavana; Park, Hyun Goo; Kim, Yong Il; An, Seongpil; Swihart, Mark T.; Yun, Je Moon; Kim, Kwang Ho; Yoon, Sam S.
2017-11-01
We demonstrate the fabrication of a MnOx/carbamide carbon nanofiber (CCNF) composite consisting of MnO particles embedded in CCNFs as a highly flexible and freestanding electrode material for supercapacitors. A sacrificial polymer component, polymethylmethacrylate, included in the precursor solution, pyrolyzes during heating, resulting in pores in the fibers, some of which are filled by the MnO nanocrystals. Carbamide is added to control the size of the MnOx particles as well as to increase the carbon content of the composite and hence its conductivity. The X-ray diffraction and Raman spectra of the composite show that the MnO particles formed have low crystallinity. Transmission electron microscopy confirms that the MnO particles are distributed very uniformly over the CCNFs. Symmetric supercapacitors constructed using electrodes of this composite exhibit specific capacitances of 498 F•g-1 at a scan rate of 10 mV•s-1 and 271 F•g-1 at a current density of 1 A•g-1. They also exhibit excellent long-term cycling performance, retaining 93% of their initial capacity after 5000 cycles of galvanostatic charging/discharging.
Peroxide as a Novel Treatment for Ecchymoses
Sroa, Novie; Campbell, Shannon M.; Bechtel, Mark A.; Mitch Opremcak, E.
2010-01-01
Ecchymoses, commonly known as bruises, frequently occur after injury to the skin causes extravasation of red blood cells into interstitial tissue. This extravasation can lead to an inflammatory cascade. The case report presented details one patient who displayed rapid improvement in the pain and appearance of a partially treated bruise on her thigh after an eight-hour application of hydrogen peroxide 15% carbamide gel under occlusion. Hydrogen peroxide 15% carbamide gel may represent a novel treatment for ecchymoses. This potential new treatment for bruises needs to be studied further to detail its adverse effects, safety profile, and efficacy profile. PMID:21103315
Evaluation of the bleached human enamel by Scanning Electron Microscopy.
Miranda, Carolina Baptista; Pagani, Clovis; Benetti, Ana Raquel; Matuda, Fábio da Silva
2005-06-01
Since bleaching has become a popular procedure, the effect of peroxides on dental hard tissues is of great interest in research. The aim of this in vitro study was to perform a qualitative analysis of the human enamel after the application of in-office bleaching agents, using Scanning Electron Microscopy (SEM). Twenty intact human third molars extracted for orthodontic reasons were randomly divided into four groups (n=5) treated as follows: G1- storage in artificial saliva (control group); G2- four 30-minute applications of 35% carbamide peroxide (total exposure: 2h); G3- four 2-hour exposures to 35% carbamide peroxide (total exposure: 8h); G4- two applications of 35% hydrogen peroxide, which was light-activated with halogen lamp at 700mW/cm² during 7min and remained in contact with enamel for 20min (total exposure: 40min). All bleaching treatments adopted in this study followed the application protocols advised by manufacturers. Evaluation of groups submitted to 35% carbamide peroxide was carried out after two time intervals (30 minutes and 2 hours per session), following the extreme situations recommended by the manufacturer. Specimens were prepared for SEM analysis performing gold sputter coating under vacuum and were examined using 15kV at 500x and 2000x magnification. Morphological alterations on the enamel surface were similarly detected after bleaching with either 35% carbamide peroxide or 35% hydrogen peroxide. Surface porosities were characteristic of an erosive process that took place on human enamel. Depression areas, including the formation of craters, and exposure of enamel rods could also be detected. Bleaching effects on enamel morphology were randomly distributed throughout enamel surface and various degrees of enamel damage could be noticed. In-office bleaching materials may adversely affect enamel morphology and therefore should be used with caution.
The potential of dental-protective chewing gum in oral health interventions.
Ly, Kiet A; Milgrom, Peter; Rothen, Marilynn
2008-05-01
The authors provide an overview of chewing gum as a delivery vehicle for dental-protective agents, highlighting xylitol and its potential application in caries-prevention programs for children. The authors reviewed selected clinical investigations and previous reviews associated with chewing gum containing substances such as calcium, bicarbonate, carbamide, chlorhexidine, fluoride and xylitol and their effects on reducing caries. They searched the MEDLINE database by using the key words "dental caries," "oral health," "calcium," "bicarbonate," "carbamide," "chlorhexidine," "fluoride" and "xylitol." Chewing gum is being used as a delivery vehicle for substances such as calcium, bicarbonate, carbamide, chlorhexidine, fluoride and xylitol to improve oral health and reduce caries. These substances exhibit properties that are protective of the oral environment and mediate common oral diseases. The debate for advocating xylitol use in caries prevention is advancing; however, chewing gum use by young schoolchildren in the United States is hindered by choking hazard concerns and lack of specific xylitol dosing recommendations. The use of chewing gum containing dental-protective substances, particularly xylitol, in caries-prevention programs can reduce the tooth decay epidemic. Chewing gum use by children in the school setting should be reconsidered.
Bollineni, Swetha; Janga, Ravi Kumar; Venugopal, L; Reddy, Indukuri Ravikishore; Babu, P Ravisekhar; Kumar, Sunil S
2014-05-01
The use of self-administered carbamide peroxide bleaching gels has become increasingly popular for whitening of discolored vital teeth. Studies have reported that its use may induce increased levels of sensitivity and surface roughness of the tooth due to demineralization. This study evaluates the effect of fluoride addition to the bleaching agent - its remineralizing capacity and alterations in the whitening properties. Twenty-four extracted lower third molar teeth, with the pretreatment shade determined, were taken up in the study. Each tooth was sectioned into four and labeled as groups A, B, C, and D. The tooth quadrants in group A-C were demineralized; groups A and B were treated with 10% carbamide peroxide gel (group-A without fluoride and group-B with 0.463% fluoride addition) (no further treatment was carried out for group c) group-D remained as the control. The post-treatment shade was determined. The tooth samples were sectioned (approximately 200 μm) for evaluation under a light microscope. The depth of demineralization was analyzed at five different equidistant points. Statistical analysis was carried out with t-tests, accepting ≤0.05 as significant. Addition of fluoride caused remineralization of demineralized enamel. The tooth whitening system showed that the remineralization properties did not affect the whitening properties.
A clinical assessment of the effects of 10% carbamide peroxide gel on human pulp tissue.
Anderson, D G; Chiego, D J; Glickman, G N; McCauley, L K
1999-04-01
Bleaching vital teeth with 10% carbamide peroxide gel is a routine procedure in which there has been no evidence of associated permanent pulpal damage. Synthesis of the enzyme heme oxygenase-1 (HO-1) is increased after exposure of eukaryotic cells to conditions of oxidative stress (including H2O2) as a defense against the damaging effects of free radicals. Dental pulps were evaluated for HO-1 (aka Heat Shock Protein 32) presence in teeth treated with 10% carbamide peroxide. Seventeen intact first premolars scheduled for orthodontic extraction were bleached for 4 h immediately preceding extraction. Fourteen additional premolars from the same individuals were not bleached. All 31 teeth were extracted, fixed, demineralized, frozen, sectioned, and immunostained with anti-HO-1 antibody using a standard ABC protocol. There was no significant difference in the presence of HO-1 between total bleached versus total unbleached teeth using the Fisher's Exact Test (p < or = 0.05). However, the histological findings could be interpreted to suggest that coronal odontoblasts and endothelial cells in the underlying pulp proper may have the potential to respond to oxidative stress by increasing the synthesis of HO-1 (HSP32). This could represent a component of an initial defensive response by specific cells in strategic locations in the pulp that precedes classical inflammatory pathways.
Madhu, Ks; Hegde, Swaroop; Mathew, Sylvia; Lata, DA; Bhandi, Shilpa H; N, Shruthi
2013-08-01
Non vital bleaching is simple, conservative procedure for esthetic correction of discolored endodontically treated teeth. The aim of this study was to determine and compare the amount of peroxide leakage from four different bleaching agents i.e superoxol, sodium perborate, combination of superoxol & sodium perborate and carbamide peroxide during intracoronal bleaching, as the safe and effective bleaching is the need of the hour. 50 extracted maxillary centrals were selected for the study. Following standardized protocol access, cleaning and shaping by step back technique and obturation was done using guttapercha and AH plus sealer. Access was sealed with Cavit G and outer root surface was coated with wax and nail varnish. The teeth were separated into crown and root and the root portion was placed in plastic tube containing distilled water for 7days.After incubation, 3mm of gutta-percha was removed below CEJ and 2mm glass ionomer cement base was placed. Grouped into five categories based on the bleaching agent placed in pulp chamber as -group1 (control)-distilled water, group 2-sodium perborate with distilled water , group 3- 30% hydrogen peroxide ,group 4-mixture of sodium perborate and 30% hydrogen peroxide and group 5-10% carbamide peroxide gel. Peroxide leakage was measured after 24hrs using ferrothiocyanate method and optical density using spectrophotometer. Statistical analysis of the data was conducted using ANOVA and multiple comparisons within the groups was done using BONFERRONI method (Post-Hoc tests). The results showed highest peroxide penetration from 30% hydrogen peroxide followed by mixture of sodium perborate with 30% hydrogen peroxide, mixture of sodium perborate with distilled water and least penetration from 10% carbamide peroxide gel. The results were statistically significant. Radicular peroxide leakage in 10% carbamide peroxide was significantly lower than the other tested bleaching agents making it a very safe alternative for intracoronal bleaching. How to cite this article: Madhu KS, Hegde S, Mathew S, Lata DA, Bhandi SH, Shruthi N. Comparison of Radicular Peroxide Leakage from four Commonly used Bleaching agents following Intracoronal Bleaching in Endodontically treated teeth - An In Vitro Study. J Int Oral Health 2013; 5(4):49-55.
Salome, Paloma; Bueno, Renata Pla Rizzolo; Nascimento, Paulo Cicero; Pozzobon, Roselaine Terezinha
2012-01-01
The purpose of this article was to assess in vitro the effects of a catalase-based neutralizer gel in the release of residual oxygen in permanent human teeth specimens exposed to 10% carbamide peroxide. Thirty teeth specimens (5.0 x 5.0 x 3.0 mm3) were randomly divided into three groups (n = 10): Group 1, nonbleached negative control specimens; Group 2, bleached positive control specimens; and Group 3, bleached specimens exposed to a catalase-based gel. The bleaching treatment was performed six hours per day for 14 days. At the end of the bleaching treatment, Group 3 specimens were immersed in a receptacle containing the catalase-based experimental gel for three minutes. Titrations were performed to determine the quantity of residual oxygen that each test specimen released, starting immediately after the end of the bleaching treatment and exposure (or not) to the catalase-based gel, and repeated on days 1-5, 10, and 15. The values obtained were statistically analyzed by ANOVA and a Tukey post hoc test (P < 0.05). The release values of residual O2 for Group 2 were equal to those of Group 1 after 10 days and to those of Group 3 after five days. The use of a catalase-based experimental neutralizer gel, applied for three minutes, reduced by half the time required for complete release of residual oxygen from tooth structure after exposure to a 10% carbamide peroxide bleaching agent.
Structure of complexes of uranyl succinate with carbamide and dimethylurea
NASA Astrophysics Data System (ADS)
Serezhkina, L. B.; Grigor'ev, M. S.; Seliverstova, N. V.; Serezhkin, V. N.
2017-09-01
Three new succinate-containing complexes of uranyl with carbamide ( Urea) and N,N'-dimethylurea ( s-Dmur) are synthesized and studied by IR spectroscopy and X-ray diffraction. Structures of the same type, [UO2( Urea)4(H2O)][(UO2)2(C4H4O4)3] · 3H2O and [UO2( Urea)4(H2O)][(UO2)2(C4H4O4)3] · 2 Urea contain two sorts of uranium-containing complex groups, namely, mononuclear [UO2( Urea)4(H2O)]2+ cations and two-dimensional [(UO2)2(C4H4O4)3]2- anions described by crystal-chemical formulas AM 5 1 and A 2 Q 3 02, respectively ( A = UO2 2+, M 1 = Urea or H2O, Q 02 = C4H4O4 2-), and differ only in the nature of noncoordinated molecules—water and carbamide. The main structural groups of the [(UO2)2(C4H4O4)2( s-Dmur)3] crystals are [(UO2)2(C4H4O4)2( s-Dmur)3] chains belonging to the A 2 Q 2 02 M 3 1 ( A = UO2 2+, Q 02 = C4H4O4 2-, M 1 = s-Dmur) crystal-chemical group. Specific features of intermolecular interactions in the crystal structures are revealed using the Voronoi-Dirichlet method of molecular polyhedra.
Cadenaro, Milena; Breschi, Lorenzo; Nucci, Cesare; Antoniolli, Francesca; Visintini, Erika; Prati, Carlo; Matis, Bruce A; Di Lenarda, Roberto
2008-01-01
This study evaluated the morphological effects produced in vivo by two in-office bleaching agents on enamel surface roughness using a noncontact profilometric analysis of epoxy replicas. The null hypothesis tested was that there would be no difference in the micromorphology of the enamel surface during or after bleaching with two different bleaching agents. Eighteen subjects were selected and randomly assigned to two treatment groups (n=9). The tooth whitening materials tested were 38% hydrogen peroxide (HP) (Opalescence Xtra Boost) and 35% carbamide peroxide (CP) (Rembrandt Quik Start). The bleaching agents were applied in accordance with manufacturer protocols. The treatments were repeated four times at one-week intervals. High precision impressions of the upper right incisor were taken at baseline as the control (CTRL) and after each bleaching treatment (T0: first application, T1: second application at one week, T2: third application at two weeks and T3: fourth application at three weeks). Epoxy resin replicas were poured from impressions, and the surface roughness was analyzed by means of a non-contact profilometer (Talysurf CLI 1000). Epoxy replicas were then observed using SEM. All data were statistically analyzed using ANOVA and differences were determined with a t-test. No significant differences in surface roughness were found on enamel replicas using either 38% hydrogen peroxide or 35% carbamide peroxide in vivo. This in vivo study supports the null hypothesis that two in-office bleaching agents, with either a high concentration of hydrogen or carbamide peroxide, do not alter enamel surface roughness, even after multiple applications.
NASA Astrophysics Data System (ADS)
Sorozini, M.; Dos Santos, R. S.; Silva, E. M.; Dos Anjos, M. J.; Perez, C. R.
2017-05-01
Tooth bleaching is a simple technique performed with gels based on hydrogen peroxide molecules responsible for removing the tooth structure's pigmentation. The effects of the overuse of these agents on the tooth structure are not well established. Energy dispersive X-ray fluorescence (EDXRF) can be employed to analyze objects of biological origin as bone and tooth. It is very suitable analytical technique to detect demineralization processes in these tissues. The objective of this study was to use x-ray fluorescence to evaluate the effects on mineral content of enamel submitted to eight-week protocols of home bleaching gels (10% carbamide peroxide and 9.5% hydrogen peroxide), as well as bleaching strips. Four enamel fragments obtained from five teeth were subjected to bleaching for 8 weeks: Group 1- artificial saliva; Group 2-10% carbamide peroxide gel, 6 h daily; Group 3-9.5% hydrogen peroxide gel, two 30-minute applications; and Group 4-bleaching strips, twice daily for 30 min. The change in mineral content was assessed weekly using X-ray fluorescence (Artax 200). Differences were basically found in Group 4 for the concentrations of Ca and P after treatment with bleaching strips containing 10% hydrogen peroxide. For the Ca/P ratio, the differences were found in Group 2-15% carbamide peroxide (p < 0.05). X-ray fluorescence proved to be a suitable method for the evaluation of the mineral content, presenting the advantage of being able to evaluate the same area at different stages of the methodology.
Influence of Bleaching Agents on Color and Translucency of Aged Resin Composites.
Lago, Maristela; Mozzaquatro, Lisandra R; Rodrigues, Camila; Kaizer, Marina R; Mallmann, André; Jacques, Letícia B
2017-09-01
Evaluate the influence of two bleaching agents (16% carbamide peroxide-CP and 35% hydrogen peroxide-HP) on color and translucency of one resin composite (Filtek Z350 XT) in two opacities (enamel and dentin) previously aged in deionized water or red wine. Sixty specimens of each material were divided in two groups (n = 30): aged in water or red wine for 14 days. Then the specimens were divided in three subgroups (n = 10): control/no treatment, treated with 16% carbamide peroxide (Mix Night), treated with 35% hydrogen peroxide (Mix One). Color readings were performed 24 hours after polishing (baseline); after the 14 days of aging; and after bleaching treatment. Color coordinates CIE L*a*b* were measured using a spectrophotometer (SP60 X-Rite). Color change (CIEDE2000) and translucency parameter were calculated. Data were analyzed with repeated measures two-way ANOVA, and Student-Newman-Keuls tests (5%). Bleaching decreased color change in stained resin composites (aged in red wine), whereas increased it in non-stained enamel resin composites (aged in water). CP had better bleaching results with stained resin composites than HP. Translucency of non-stained dentin resin composite decreased with aging, but did not change with bleaching. For stained resin composites, aging caused reduced translucency, whereas bleaching increased it. Effective bleaching of discolored resin composites aged in an acidic and alcoholic media rich in staining agents was achieved, improving color and translucency. Carbamide peroxide showed better performance than hydrogen peroxide for the bleaching of stained resin composites. (J Esthet Restor Dent 29:368-377, 2017). © 2016 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arifvianto, B., E-mail: b.arifvianto@tudelft.nl; L
The present research was aimed at gaining an understanding of the porous structure changes from the green body through water leaching and sintering to titanium scaffolds. Micro-computed tomography (micro-CT) was performed to generate 3D models of titanium scaffold preforms containing carbamide space-holding particles and sintered scaffolds containing macro- and micro-pores. The porosity values and structural parameters were determined by means of image analysis. The result showed that the porosity values, macro-pore sizes, connectivity densities and specific surface areas of the titanium scaffolds sintered at 1200 °C for 3 h did not significantly deviate from those of the green structures withmore » various volume fractions of the space holder. Titanium scaffolds with a maximum specific surface area could be produced with an addition of 60–65 vol% carbamide particles to the matrix powder. The connectivity of pores inside the scaffold increased with rising volume fraction of the space holder. The shrinkage of the scaffolds prepared with > 50 vol% carbamide space holder, occurring during sintering, was caused by the reductions of macro-pore sizes and micro-pore sizes as well as the thickness of struts. In conclusion, the final porous structural characteristics of titanium scaffolds could be estimated from those of the green body. - Highlights: •Porous structures of green body and sintered titanium scaffolds was studied. •Porous structures of both samples were quantitatively characterized with micro-CT. •Porous structures of scaffolds could be controlled from the green body. •Shrinkage mechanisms of titanium scaffolds during sintering was established.« less
Ivanoff, Chris S; Wu, Jie Jayne; Mirzajani, Hadi; Cheng, Cheng; Yuan, Quan; Kevorkyan, Stepan; Gaydarova, Radostina; Tomlekova, Desislava
2016-10-01
AC electrokinetics (ACEK) has been shown to deliver certain drugs into human teeth more effectively than diffusion. However, using electrical wires to power intraoral ACEK devices poses risks to patients. The study demonstrates a novel interdigitated electrode arrays (IDE) assembly powered by inductive coupling to induce ACEK effects at appropriate frequencies to motivate drugs wirelessly. A signal generator produces the modulating signal, which multiplies with the carrier signal to produce the amplitude modulated (AM) signal. The AM signal goes through the inductive link to appear on the secondary coil, then rectified and filtered to dispose of its carrier signal, and the positive half of the modulating signal appears on the load. After characterizing the device, the device is validated under light microscopy by motivating carboxylate-modified microspheres, tetracycline, acetaminophen, benzocaine, lidocaine and carbamide peroxide particles with induced ACEK effects. The assembly is finally tested in a common dental bleaching application. After applying 35 % carbamide peroxide to human teeth topically or with the IDE at 1200 Hz, 5 Vpp for 20 min, spectrophotometric analysis showed that compared to diffusion, the IDE enhanced whitening in specular optic and specular optic excluded modes by 215 % and 194 % respectively. Carbamide peroxide absorbance by the ACEK group was two times greater than diffusion as measured by colorimetric oxidation-reduction and UV-Vis spectroscopy at 550 nm. The device motivates drugs of variable molecular weight and structure wirelessly. Wireless transport of drugs to intraoral targets under ACEK effects may potentially improve the efficacy and safety of drug delivery in dentistry.
Effect of bleaching agents and whitening dentifrices on the surface roughness of human teeth enamel.
Özkan, Pelin; Kansu, Gülay; Özak, Sule Tuğba; Kurtulmuş-Yilmaz, Sevcan; Kansu, Pelin
2013-01-01
The aim of this in vitro study was to evaluate the surface roughness of human enamel bleached with 10% carbamide peroxide or 10% hydrogen peroxide bleaching agents at different times and also subjected to different superficial cleaning treatments. One hundred and forty flat enamel samples were divided into 14 groups, Group 1-Group 14 (G1-G14). G1-G7 were treated with 10% carbamide peroxide and different dentifrices, G8-G14 were treated with 10% hydrogen peroxide and different dentifrices (G1 and G8: not brushed as control groups; G2 and G9: brushed with Ipana® toothpaste; G3 and G10: brushed with Clinomyn® toothpaste; G4 and G11: brushed with Moos Dent® toothpaste; G5 and G12: brushed with Signal® toothpaste; G6 and G13: brushed with Colgate® toothpaste; G7 and G14: brushed without dentifrice). A profilometer was used to measure average roughness values of the initial surface roughness and at each 7-day-interval. The bleaching was performed for 6 h a day and the surface cleaning treatment was performed 3-times a day, 2 min each time, for 4 weeks. The samples were stored in distilled water during the test period. Statistical analysis revealed significant differences in surface roughness values over time for all groups except G1 and G8 (not brushed). The results of the surface roughness of all groups were nearly the same. The bleaching with 10% hydrogen peroxide and 10% carbamide peroxide did not alter the enamel surface roughness, but when the bleaching treatment was performed combined with abrasive dentifrices, a significant increase in roughness values was observed.
Bolay, Sukran; Cakir, Filiz Yalcin; Gurgan, Sevil
2012-09-01
The aim of this in vitro study was to evaluate the surface roughness and hardness of both unbleached and bleached (opalescence; 10% carbamide peroxide) human enamel brushed with water (without dentifrice), fluoride abrasive dentifrice (Colgate Total) and whitening dentifrice (Natural White). Human enamel samples were obtained from third molars and randomly divided into five groups (n = 8): G1 - Control (brushed with water without dentifrice), G2 - Colgate Total (fluoride abrasive dentifrice), G3 - Natural White (whitening dentifrice), G4 - Opalescence (10% carbamide peroxide) and then brushed with Colgate Total, G5 - Opalescence (10% carbamide peroxide) and then brushed with Natural White. Bleaching regimen was applied according to manufacturers' instructions. The brushing process was performed with a modified Nyffenegger's brushing machine. Surface roughness was analyzed with a profilometer. Microhardness testing was performed with a Brinell hardness tester. Results were statistically analyzed by Kruskal-Wallis, one-way ANOVA analysis and Mann-Whitney U, Wilcoxon matched-pairs signed-ranks tests. There were significant differences in surface roughness values for all groups, which showed an increase in roughness (p < 0.05). When the bleaching treatment combined with brushing with whitening dentifrice was performed (G5), there was a significant decrease in hardness values (p < 0.05). The other groups (G1, G2, G3, G4) showed no significant hardness differences (p > 0.05). It was concluded that toothbrushing procedures increased the enamel surface roughness, and that bleaching regimen performed with cleaning treatment, through brushing with whitening dentifrice decreased hardness values. When applied together, bleaching and cleaning treatments may alter the enamel surface roughness and hardness values.
Does the Use of a "Walking Bleaching" Technique Increase Bone Resorption Markers?
Bersezio, C; Vildósola, P; Sáez, M; Sánchez, F; Vernal, R; Oliveira, O B; Jorquera, G; Basualdo, J; Loguercio, A; Fernández, E
This randomized clinical trial evaluated the effect of 35% hydrogen peroxide in comparison with 37% carbamide peroxide in a nonvital bleaching technique of "walking bleaching" (four sessions of treatment) on periodontal markers: nuclear factor kappa B-ligand (RANK-L-process of root resorption marker) and interleukin 1β (IL-1β-inflammatory response marker). Fifty volunteers presenting with discoloration of nonvital teeth and endodontic treatment in good condition participated. Fifty teeth were randomly divided into two study groups according to bleaching gel: HP = 35% hydrogen peroxide (n=25) and 37% carbamide peroxide (n=25). Nonvital bleaching was performed with a walking bleaching technique consisting of four sessions of bleach application. Gingival crevicular fluid samples were taken in order to quantify the RANK-L and IL-1β levels by enzyme-linked immunosorbent assay. Samples were obtained from six periodontal sites for each bleached tooth: three vestibular and three palatine (mesial, middle, and distal) at seven time periods: baseline, after each of the four sessions of nonvital bleaching, at one week, and at one month after nonvital bleaching. Tooth color variations were analyzed in each session by VITA Bleachedguide 3D-MASTER (ΔSGU). Significant increments in the RANK-L and IL-1β levels were detected in each evaluated time compared with baseline ( p<0.05); however, no differences were detected between hydrogen peroxide and carbamide peroxide on increments of the biomarkers studied. The change of color was effective for both nonvital bleaching therapies ( p<0.05). Nonvital bleaching induced a significant increment in the RANK-L and IL-1β levels in periodontal tissues around bleached, nonvital teeth.
Synthesis and X-ray diffraction study of new uranyl malonate and oxalate complexes with carbamide
DOE Office of Scientific and Technical Information (OSTI.GOV)
Medvedkov, Ya. A.; Serezhkina, L. B., E-mail: Lserezh@samsu.ru; Grigor’ev, M. S.
2016-05-15
Two new malonate-containing uranyl complexes with carbamide of the formulas [UO{sub 2}(C{sub 3}H{sub 2}O{sub 4})(Urea){sub 2}] (I) and [UO{sub 2}(C{sub 3}H{sub 2}O{sub 4})(Urea){sub 3}] (II), where Urea is carbamide, and one uranyl oxalate complex of the formula [UO{sub 2}(C{sub 2}O{sub 4})(Urea){sub 3}] (III) were synthesized, and their crystals were studied by X-ray diffraction. The main structural units in crystals I are the electroneutral chains [UO{sub 2}(C{sub 3}H{sub 2}O{sub 4})(Urea){sub 2}]{sub ∞} belonging to the crystal-chemical group AT{sup 11}M{sub 2}{sup 1} (A = UO{sub 2}{sup 2+}, T{sup 11} = C{sub 3}H{sub 2}O{sub 4}{sup 2-}, M{sup 1} = Urea) of uranyl complexes.more » Crystals II and III are composed of the molecular complexes [UO{sub 2}(L)(Urea){sub 3}], where L = C{sub 3}H{sub 2}O{sub 4}{sup 2-} or C{sub 2}O{sub 4}{sup 2-}, belonging to the crystal-chemical group AB{sup 01}M{sub 3}{sup 1} (A = UO{sub 2}{sup 2+}, B{sup 01} = C{sub 3}H{sub 2}O{sub 4}{sup 2-} or C{sub 2}O{sub 4}{sup 2-}, M{sup 1} = Urea). The characteristic features of the packing of the uranium-containing complexes are discussed in terms of molecular Voronoi–Dirichlet polyhedra. The effect of the Urea: U ratio on the structure of uranium-containing structural units is considered.« less
Cibirka, R M; Myers, M; Downey, M C; Nelson, S K; Browning, W D; Hawkins, I K; Dickinson, G L
1999-01-01
Prescribed, patient-applied tooth lightening agents, or nightguard vital bleaching, typically utilizes a 10% carbamide peroxide agent applied during nocturnal hours. The purpose of this randomized double-blind study was to compare the amount of tooth color change in two groups of subjects using dentist-supervised, patient-applied 10% carbamide peroxide gel. One group used Opalescence (Ultradent Products Inc., South Jordan, Utah) and the other NiteWhite Excel (Discus Dental, Inc., Los Angeles, California). Evaluation of tooth color for the six maxillary anterior teeth was done using a Vita shade guide at baseline, 1, 2, and 4 weeks. Subjects were instructed to apply the gel nocturnally using a custom-made soft tray 8 hours per day for 2 weeks. The 16 tabs of the shade guide were ranked according to value from darkest to lightest. The number (1-16) that correlated to the shade tab selected as the match for each tooth was the outcome variable. A Kruskal-Wallis one way analysis of variance on ranks was used. The test revealed no statistically significant difference between Opalescence and NiteWhite Excel for lightening the teeth (p = .807). The color change was still significant after 2 weeks without further bleaching activity. The baseline evaluation of the maxillary incisors and canines for all subjects, regardless of group, demonstrated a significant shade difference, with the canines being darker. This difference was not seen after 2 weeks of active bleaching or at the 4-week evaluation. In this study comparing bleaching products, patients using Opalescence and NiteWhite Excel experienced a significant change in the color of their teeth relative to baseline values after 2 weeks of active treatment.
Erosion and abrasion on dental structures undergoing at-home bleaching
Demarco, Flávio Fernando; Meireles, Sônia Saeger; Sarmento, Hugo Ramalho; Dantas, Raquel Venâncio Fernandes; Botero, Tatiana; Tarquinio, Sandra Beatriz Chaves
2011-01-01
This review investigates erosion and abrasion in dental structures undergoing at- home bleaching. Dental erosion is a multifactorial condition that may be idiopathic or caused by a known acid source. Some bleaching agents have a pH lower than the critical level, which can cause changes in the enamel mineral content. Investigations have shown that at-home tooth bleaching with low concentrations of hydrogen or carbamide peroxide have no significant damaging effects on enamel and dentin surface properties. Most studies where erosion was observed were in vitro. Even though the treatment may cause side effects like sensitivity and gingival irritation, these usually disappear at the end of treatment. Considering the literature reviewed, we conclude that tooth bleaching agents based on hydrogen or carbamide peroxide have no clinically significant influence on enamel/dentin mineral loss caused by erosion or abrasion. Furthermore, the treatment is tolerable and safe, and any adverse effects can be easily reversed and controlled. PMID:23674914
Fabrication and characterization of magnesium scaffold using different processing parameters
NASA Astrophysics Data System (ADS)
Toghyani, Saeid; Khodaei, Mohammad
2018-03-01
Structural and mechanical properties of scaffolds are important for hard tissue reconstruction. In this study, magnesium scaffolds were fabricated using space holder method for bone tissue reconstruction and the effect of cold compaction pressure and also volume percent of porosity on structural and mechanical properties of scaffolds were investigated using scanning electron microscopy (SEM) and uniaxial compression test. The carbamide spacer agent was also removed after pellet compaction, using NaOH solution and ethanol for the first time and their effect on phases present in scaffold after sintering was investigated using x-ray diffraction (XRD) analysis. Based on the results of mechanical and structural assessments, the optimum cold compaction pressure was selected 350 MPa for pellet compaction. The elastic modulus and strength of magnesium scaffolds including 67 vol.% porosity were in the range of 0.20–0.28 GPa and 4–4.25 MPa, respectively which is comparable to cancellous bone tissue. The mechanical properties of magnesium scaffolds decreased by increasing the porosity. The results also revealed that ethanol is a more suitable liquid for carbamide removal compared to NaOH solution.
Study of sintering on Mg-Zn-Ca alloy system
NASA Astrophysics Data System (ADS)
Annur, Dhyah; Lestari, Franciska P.; Erryani, Aprilia; Kartika, Ika
2018-05-01
Magnesium and its alloy have gained a lot of interest to be used in biomedical application due to its biodegradable and biocompatible properties. In this study, sintering process in powder metallurgy was chosen to fabricatenonporous Mg-6Zn-1Ca (in wt%) alloy and porous Mg-6Zn-1Ca-10 Carbamide alloy. For creating porous alloy, carbamide (CO(NH2)2 was added to alloy system as the space holder to create porous structure material. Effect of the space holder addition and sintering temperature on porosity, phase formation, mechanical properties, and corrosion properties was observed. Sintering process was done in a tube furnace under Argon atmosphere in for 5 hours. The heat treatment was done in two steps; heated up at 250 °C for 4 hours to decompose spacer particle, followed by heated up at 580 °C or 630 °C for 5 hours. The porous structure of the resulted alloys was examined using Scanning Electron Microscope (SEM), while the phase formation was characterized by X-ray diffraction (XRD) analysis. Mechanical properties were examined using compression testing. From this study, increasing sintering temperature up to 630 °C reduced the mechanical properties of Mg-Zn-Ca alloy.
Soares, Diana Gabriela; Ribeiro, Ana Paula Dias; Sacono, Nancy Tomoko; Loguércio, Alessandro Dourado; Hebling, Josimeri; Costa, Carlos Alberto de Souza
2013-01-01
The aim of this study was to compare the effect of a 16% carbamide peroxide (CP) gel and a 10% CP gel on mineralized enamel content and morphology. Enamel blocks from bovine incisors were subjected to a 14-day treatment (8 h/day) with 10% or 16% CP gels. Knoop microhardness was evaluated before bleaching and at 1, 7 or 14 days after this treatment (50 g/15 s). Mineral content (energy-dispersive x-ray spectroscopy), surface roughness and topography (atomic force microscopy) were evaluated at the 14-day period. Data were analyzed statistically by two-way ANOVA and Tukey's test (α=0.05). Significant microhardness reduction was observed at the 7 th and 14 th days for 10% CP gel, and for all bleaching times for 16% CP gel (p<0.05). At the 14-day period, a significant decrease in Ca and P content, increase on surface roughness (p<0.05) as well as on picks and valleys distance were observed when both bleaching gels were used. These enamel alterations were more intense for 16% CP gel. It was concluded that both CP-based gels promoted loss of mineral structure from enamel, resulting in a rough and porous surface. However, 16% CP gel caused the most intense adverse effects on enamel.
Melo, Carolina França de Medeiros; Manfroi, Fernanda Borguetti; Spohr, Ana Maria
2014-01-01
Background: This in situ study evaluated the roughness and microhardness of enamel bleached with 10% carbamide peroxide (PC10) and brushed with different toothpastes. Materials and Methods: Two groups of volunteers received PC10 and placebo agents for 21 days in two phases in a crossover 2 × 3 study. Fragments of human enamel were distributed among intraoral removable appliances (IRA). Nine fragments, divided into three triplets, were used in each IRA, and these were brushed with toothpastes R (Colgate), W (Colgate Total 12 Whiteness Gel) or BS (Colgate Whitening Oxygen Bubbles Fluoride). Treatments agents were applied for 8 h overnight. After brushing, the volunteers used the IRA for about 16 h/day. After a washout period, new IRAs were distributed and the volunteers were crossed over to the alternate agent for 21 days. Roughness and microhardness were measured before and after each phase. Results: According to the paired Student’s t-test, roughness of enamel increased and microhardness decreased (P < 0.05). According to analysis of variance generalized linear models, only the toothpaste factor was significant (P = 0.037) for roughness. Conclusion: Enamel microhardness and surface roughness are altered when PC10 bleaching is associated with tooth brushing using toothpastes BS, R, and W. PMID:25214727
Smile restoration through use of enamel microabrasion associated with tooth bleaching.
Sundfeld, Renato Herman; Rahal, Vanessa; de Alexandre, Rodrigo Sversut; Briso, André Luiz Fraga; Sundfeld Neto, Daniel
2011-01-01
Enamel microabrasion can eliminate enamel irregularities and discoloration defects, improving the appearance of teeth. This article presents the latest treatment protocol of enamel microabrasion to remove stains on the enamel surface. It has been verified that teeth submitted to microabrasion acquire a yellowish color because of the thinness of the remaining enamel, revealing the color of dentinal tissue to a greater degree. In these clinical conditions, correction of the color pattern of these teeth can be obtained with a considerable margin of clinical success using products containing carbamide peroxide in custom trays. Thus, patients can benefit from combined enamel microabrasion/tooth bleaching therapy, which yields attractive cosmetic results. Esthetics plays an important role in contemporary dentistry, especially because the media emphasizes beauty and health. Currently, in many countries, a smile is considered beautiful if it imitates a natural appearance, with clear, well-aligned teeth and defined anatomical shapes. Enamel microabrasion is one technique that can be used to correct discolored enamel. This technique has been elucidated and strongly advocated by Croll and Cavanaugh since 1986, and by other investigators who suggested mechanical removal of enamel stains using acidic substances in conjunction with abrasive agents. Enamel microabrasion is indicated to remove intrinsic stains of any color and of hard texture, and is contraindicated for extrinsic stains, dentinal stains, for patients with deficient labial seals, and in cases where there is no possibility to place a rubber dam adequately during the microabrasion procedure. It should be emphasized that enamel microabrasion causes a microreduction on the enamel surface, and, in some cases, teeth submitted to microabrasion may appear a darker or yellowish color because the thin remaining enamel surface can reveal some of the dentinal tissue color. In these situations, according to Haywood and Heymann in 1989, correction of the color pattern of teeth can be obtained through the use of whitening products containing carbamide peroxide in custom trays. A considerable margin of clinical success has been shown when diligence to at-home protocols is achieved by the patient and supervised by the professional. Considering these possibilities, this article presents the microabrasion technique for removal of stains on dental enamel, followed by tooth bleaching with carbamide peroxide and composite resin restoration, if required.
Evaluating the bonding of two adhesive systems to enamel submitted to whitening dentifrices.
Briso, André Luiz Fraga; Toseto, Roberta Mariano; de Arruda, Alex Mendes; Tolentino, Patricia Ramos; de Alexandre, Rodrigo Sversut; dos Santos, Paulo Henrique
2010-01-01
The aim of this study was to evaluate by micro-shear bond strength test, the bond strength of composite resin restoration to enamel submitted to whitening dentifrices. Forty bovine teeth were embedded in polystyrene resin and polished. The specimens were randomly divided into eight groups (n=5), according to the dentifrice (carbamide peroxide, hydrogen peroxide and conventional dentifrice) and the adhesive system (Prime & Bond 2.1 and Adper Single Bond 2). Dentifrice was applied for 15 minutes a day, for 21 days. Thirty minutes after the last exposure to dentifrice, the samples were submitted to a bonding procedure with the respective adhesive system. After that, four buttons of resin were bonded in each sample using transparent cylindrical molds. After 24 hours, the teeth were submitted to the micro-shear bond strength test and subsequent analysis of the fracture mode. Data were submitted to analysis of variance and Fisher's PLSD test (alpha = 0.05). The micro-shear bond strength showed no difference between adhesives systems but a significant reduction was found between the control and carbamide groups (p = 0.0145) and the control and hydrogen groups (p = 0.0370). The evaluation of the failures modes showed that adhesive failures were predominant. Cohesive failures were predominant in group IV The use of dentifrice with peroxides can decrease bonding strength in enamel.
Clinical and Spectrophotometric Evaluation of LED and Laser Activated Teeth Bleaching.
Lo Giudice, R; Pantaleo, G; Lizio, A; Romeo, U; Castiello, G; Spagnuolo, G; Giudice, G Lo
2016-01-01
Auxiliary power sources (LED and laser) are used in in-office teeth bleaching techniques to accelerate the redox reaction of the whitening gel to increase ease of use, to improve comfort and safety, and to decrease the procedure time. The aim this study is to evaluate the efficiency of the teeth whitening procedures performed with hydrogen peroxide and carbamide peroxide, LED or Laser activated. 18 patients, affected by exogenous dyschromia, were treated with a bleaching agent composed by 35% hydrogen peroxide and 10% carbamide peroxide. They were divided into two groups: in the first group the bleaching agent was activated by a LED lamp; in the second group it was activated by a Laser diode lamp. Both groups were subjected to 3 bleaching cycle of 15' each. The chromatic evaluations were performed before and after one week from the treatment, using a chromatic scale and a spectrophotometer. The mean value of pre, post bleaching and follow-up were analyzed using a T-test, with results statistically significant for P<0,05. Results showed that the variations in brightness, chroma and hue are significantly influenced by the interaction between the whitening agent and the original colour of the teeth. Laser-activation has marginally improved the bleaching effectiveness. All patients treated with laser activation complained an increase in dental sensitivity. The use of laser-activating systems did not improve the efficacy of bleaching.
N-(Adamantan-1-yl)-1,2,3,4-tetra-hydro-iso-quinoline-2-carbo-thio-amide.
El-Emam, Ali A; Al-Abdullah, Ebtehal S; Al-Tuwaijri, Hanaa M; Chidan Kumar, C S; Fun, Hoong-Kun
2013-11-23
In the title compound, C20H26N2S, the N-containing six-membered ring adopts a boat conformation and the dihedral angle between the thio-carbamide group and the benzene ring is 49.67 (9)°. An intra-molecular C-H⋯S hydrogen bond generates an S(6) ring motif. The N-H group is sterically hindered and there are no significant inter-molecular inter-actions beyond van der Waals contacts.
NASA Astrophysics Data System (ADS)
Shkir, Mohd.; Irfan, Ahmad; AlFaify, S.; Ganesh, V.; Arora, M.; Muhammad, Shabbir; Al-Sehemi, Abdullah G.; Yahia, I. S.
2018-03-01
Large size single crystals of Diiodo-bis(carbamide)-zinc(II) [ZnI2. 2[CO(NH2)2] were grown successfully for the first time by slow evaporation techniques at room temperature within the evaporation time of two weeks. The single phase and high crystalline nature of the grown crystals was confirmed by X-ray diffraction analysis. Quantum chemically the geometrical parameters were found in good correlation with experimental values calculated at B3LYP/6-31G* (LANL2DZ), B2LYPD/6-31G* (LANL2DZ), M062X/6-31G* (LANL2DZ) and MP2/6-31G* (LANL2DZ) level of theories. Additionally, the experimental vibrational modes also have shown a good agreement with calculated ones. The optical transparency and band gap were calculated and found to be ∼80% and 4.706 eV, respectively. The calculated value of HOMO-LUMO gap was found in correlation with experimental energy gap. The electronic properties were investigated by shedding light on the frontier molecular orbitals, partial density of states (PDOS), and total density of states (TDOS). The mechanical and dielectric studies show that the grown crystals possess quite good mechanical strength and dielectric constant. The dielectric loss revealed that the grown crystal contains low defects. The total ac electrical conductivity was increased with frequency and the frequency components confirm the sudden hoping mechanism in the grown crystal.
Separate whitening effects on enamel and dentin after fourteen days.
Kugel, Gerard; Petkevis, Jason; Gurgan, Sevil; Doherty, Eileen
2007-01-01
The purpose of this study was to investigate the mechanism of action of a bleaching agent, as it relates to enamel and dentin. Twenty-six extracted human molar teeth were sectioned at the cemento-enamel junction and were randomly assigned to two groups. L*a*b* readings were taken with a spectrophotometer: on buccal surfaces of the crown, at enamel and dentin. The teeth were exposed to carbamide peroxide or placebo gel and L*a*b* scores were again recorded to determine color changes. Treatments were compared using ancova test with baseline color as the covariate. Relative to placebo, buccal surfaces exhibited the greatest Deltab* and DeltaL* color change. On buccal surfaces, the adjusted mean (SE) treatment differences were -7.8 (1.00) for Deltab* and 5.7 (0.97) for DeltaL, with groups differing significantly (p < 0.0001). On enamel surfaces, treatment differences were -3.6 (0.61) for Deltab* and 4.6 (0.80) for DeltaL* (p < 0.0001). Dentin exhibited the least color improvement. Adjusted mean (SE) treatment differences were -1.9 (0.87) for Deltab* and 2.4 (1.10) for DeltaL*, with groups differing significantly (p < 0.02) on dentin color change. The majority of color change seen on the buccal surface of tooth crowns exposed to carbamide peroxide 15% was because of the color change in enamel. As compared to enamel, dentin was less affected after 14 days.
Soares, Diana Gabriela; Ribeiro, Ana Paula Dias; Lima, Adriano Fonseca; Sacono, Nancy Tomoko; Hebling, Josimeri; de Souza Costa, Carlos Alberto
2013-01-01
The aim of this study was to evaluate the possibility of fluoride solutions applied to enamel to protect pulp cells against the trans-enamel and transdentinal cytotoxicity of a 16% carbamide peroxide (CP) bleaching gel. The CP gel was applied to enamel/dentin discs adapted to aicial pulp chambers (8 h/day) during 1, 7 or 14 days, followed by fluoride (0.05% or 0.2%) application for 1 min. The extracts (culture medium in contact with dentin) were applied to MDPC-23 cells for 1 h, and cell metabolism (MTT assay), alkaline phosphatase (ALP) activity and cell membrane damage (flow cytometry) were analyzed. Knoop microhardness of enamel was also evaluated. Data were analyzed statistically by ANOVA and Kruskal-Wallis tests (α=0.05). For the MTT assay and ALP activity, significant reductions between the control and the bleached groups were observed (p<0.05). No statistically significant difference occurred among bleached groups (p>0.05), regardless of fluoride application or treatment days. Flow cytometry analysis demonstrated 30% of cell membrane damage in all bleached groups. After 14 days of treatment, the fluoride-treated enamel presented significantly higher microhardness values than the bleached-only group (p<0.05). It was concluded that, regardless of the increase in enamel hardness due to the application of fluoride solutions, the treated enamel surface did not prevent the toxic effects caused by the 16% CP gel to odontoblast-like cells.
Clinical and Spectrophotometric Evaluation of LED and Laser Activated Teeth Bleaching
Lo Giudice, R.; Pantaleo, G.; Lizio, A.; Romeo, U.; Castiello, G.; Spagnuolo, G.; Giudice, G. Lo
2016-01-01
Background: Auxiliary power sources (LED and laser) are used in in-office teeth bleaching techniques to accelerate the redox reaction of the whitening gel to increase ease of use, to improve comfort and safety, and to decrease the procedure time. Objective: The aim this study is to evaluate the efficiency of the teeth whitening procedures performed with hydrogen peroxide and carbamide peroxide, LED or Laser activated. Method: 18 patients, affected by exogenous dyschromia, were treated with a bleaching agent composed by 35% hydrogen peroxide and 10% carbamide peroxide. They were divided into two groups: in the first group the bleaching agent was activated by a LED lamp; in the second group it was activated by a Laser diode lamp. Both groups were subjected to 3 bleaching cycle of 15’ each. The chromatic evaluations were performed before and after one week from the treatment, using a chromatic scale and a spectrophotometer. The mean value of pre, post bleaching and follow-up were analyzed using a T-test, with results statistically significant for P<0,05. Results: Results showed that the variations in brightness, chroma and hue are significantly influenced by the interaction between the whitening agent and the original colour of the teeth. Laser-activation has marginally improved the bleaching effectiveness. All patients treated with laser activation complained an increase in dental sensitivity. Conclusion: The use of laser-activating systems did not improve the efficacy of bleaching. PMID:27386010
Llena, Carmen; Esteve, Irene; Forner, Leopoldo
2017-07-01
The aim of the study was to evaluate the bleaching effect, morphological changes, and variations in calcium (Ca) and phosphate (P) in the enamel with hydrogen peroxide (HP) and carbamide peroxide (CP) after the use of different application regimens. Four groups of five teeth were randomly assigned, according to the treatment protocol: HP 37.5% applied for 30 or 60 minutes (HP30, HP60), CP 16% applied for 14 or 28 hours (CP14, CP28). Changes in dental color were evaluated, according to the following formula: ΔE = [(L a -L b ) 2 +(a a -a b ) 2 + (b a -b b ) 2 ] 1/2 . Enamel morphology and Ca and P compositions were evaluated by confocal laser scanning microscope and environmental scanning electron microscopy. ΔE HP30 was significantly greater than CP14 (10.37 ± 2.65/8.56 ± 1.40), but not between HP60 and CP28. HP60 shows greater morphological changes than HP30. No morphological changes were observed in the groups treated with CP. The reduction in Ca and P was significantly greater in HP60 than in CP28 (p < 0.05). Both formulations improved tooth color; HP produced morphological changes and Ca and P a gradual decrease, while CP produced no morphological changes, and the decrease in mineral component was smaller. CP 16% applied during 2 weeks could be equally effective and safer for tooth whitening than to administer two treatment sessions with HP 37.5%.
Chauhan, Vikas; Kumar, Piush; Sharma, Payal; Shetty, Divya
2017-01-01
To investigate the effect of different intracoronal bleaching methods on the shear bond strength and site of failure of ceramic brackets. Sixty freshly extracted human maxillary incisors were randomly divided into four groups ( n = 15). Endodontic access cavity was prepared and root canals were filled, root fillings were removed 2mm apical to the cementoenamel junction, and a 2-mmthick layer of glass ionomer cement base was applied. Group 1 served as the control. Intracoronal bleaching was performed with 35% carbamide peroxide in group 2, sodium perborate in group 3, and 37.5% hydrogen peroxide in group 4. The teeth were immersed in artificial saliva for 4 weeks before bracket bonding. Ceramic brackets were bonded with composite resin and cured with LED light. After bonding, the shear bond strength of the brackets was tested with a universal testing machine. The site of bond failure was determined by modified ARI (Adhesive Remnant Index). The highest value of shear bond strength was measured in control group (18.67 ± 1.59 MPa), which was statistically significant from groups 2,3, and 4. There was no significant difference between groups 2 and 4. The lowest shear bond strength was measured in group 3. ARI scores were not significant from each other. Intracoronal bleaching significantly affected the shear bond strength of ceramic brackets even after 4 weeks of bleaching. Bleaching with sodium perborate affects shear bond strength more adversely than does bleaching with other agents like hydrogen peroxide and carbamide peroxide.
Maran, Bianca Medeiros; Vochikovski, Laína; de Andrade Hortkoff, Diego Rafael; Stanislawczuk, Rodrigo; Loguercio, Alessandro D; Reis, Alessandra
2018-05-01
Desensitizing agents are usually included in the composition of bleaching agents to reduce bleaching-induced tooth sensitivity (TS). This randomized clinical trial (RCT) evaluated the risk and intensity of TS and color change after at-home bleaching with a desensitizing-containing (3% potassium nitrate and 0.2% sodium fluoride) and desensitizing-free 10% carbamide peroxide (CP) gel (Whiteness Perfect, FGM). A triple-blind, within-person RCT was conducted on 60 caries-free adult patients. Each participant used the gel in a bleaching tray for 3 h daily for 21 days in both the upper and lower dental arches. The absolute risk and intensity of TS were assessed daily through the 0-10 VAS and NRS scale for 21 days. Color change was recorded using shade guides (Vita Classical and Vita Bleachedguide) and the Easyshade spectrophotometer at baseline, weekly and 30 days after the end of the bleaching. The risk and intensity of TS were evaluated by the McNemar and Wilcoxon Signed Rank tests, respectively. Color change (ΔSGU and ΔE) were evaluated by the Mann-Whitney test and a paired t-test, respectively (α = 0.05). No difference in the TS and color change was observed (p > 0.05). The incorporation of potassium nitrate and sodium fluoride in 10% carbamide peroxide at-home bleaching gel tested in this study did not reduce the TS and did not affect color change (RBR-4M6YR2). Copyright © 2018 Elsevier Ltd. All rights reserved.
Inflammatory response of human dental pulp to at-home and in-office tooth bleaching
Vaz, Maysa Magalhães; Lopes, Lawrence Gonzaga; Cardoso, Paula Carvalho; de Souza, João Batista; Batista, Aline Carvalho; Costa, Nádia Lago; Torres, Érica Miranda; Estrela, Carlos
2016-01-01
ABSTRACT Tooth bleaching is a technique of choice to obtain a harmonious smile, but bleaching agents may damage the dental pulp. Objective: This study evaluated the inflammatory responses of human dental pulp after the use of two bleaching techniques. Material and Methods: Pulp samples were collected from human third molars extracted for orthodontic reasons and divided into three groups: control - no tooth bleaching (CG) (n=7); at-home bleaching with 15% carbamide peroxide (AH) (n = 10), and in-office bleaching with 38% hydrogen peroxide (IO) (n=12). Pulps were removed and stained with hematoxylin-eosin for microscopic analysis of inflammation intensity, collagen degradation, and pulp tissue organization. Immunohistochemistry was used to detect mast cells (tryptase+), blood vessels (CD31+), and macrophages (CD68+). Chi-square, Kruskal-Wallis, and Mann Whitney tests were used for statistical analysis. The level of significance was set at p<.05. Results: The inflammation intensity and the number of macrophages were significantly greater in IO than in AH and CG (p<0.05). The results of CD31+ (blood vessels per mm2) were similar in CG (61.39±20.03), AH (52.29±27.62), and IO (57.43±8.69) groups (p>0.05). No mast cells were found in the pulp samples analyzed. Conclusion: In-office bleaching with 38% hydrogen peroxide resulted in more intense inflammation, higher macrophages migration, and greater pulp damage then at-home bleaching with 15% carbamide peroxide, however, these bleaching techniques did not induce migration of mast cells and increased the number of blood vessels. PMID:27812622
Effect of bleaching on microhardness of esthetic restorative materials.
Malkondu, Özlem; Yurdagüven, Haktan; Say, Esra Can; Kazazoğlu, Ender; Soyman, Mübin
2011-01-01
This study evaluated the effect of a high-concentration carbamide peroxide–containing home bleaching system (Opalescence PF) and a hydrogen peroxide–containing over-the-counter bleaching system (Treswhite Supreme) on the microhardness of two nanocomposites (Filtek Supreme XT and Premise) and leucite-reinforced glass ceramic (Empress Esthetic), glass ceramic (Empress 2 layering), and feldspathic porcelain (Matchmaker MC). A total of 100 specimens, 20 of each kind of the restorative materials, 2 mm in thickness and 10 mm in diameter, were fabricated. Then the specimens were polished with SiC paper and 1 μm alumina polishing paste. After polishing, porcelain specimens were glazed in accordance with the manufacturer's instructions. Each type of restorative material was then randomly divided into two groups (n=10), and the specimens were treated with either Opalescence PF or Treswhite Supreme. The microhardness of the specimens before bleaching (baseline) and after bleaching was determined using a digital microhardness tester. Data were analyzed using the Mann-Whitney U-test and the Wilcoxon test. Opalescence PF significantly influenced the hardness of all the restorative materials. Statistically significant decreases with respect to before bleaching were found for Premise (p=0.005), Empress Esthetic (p=0.003), Empress 2 layering (p=0.005), and Matchmaker-MC (p=0.003), whereas a statistically significant increase was observed in Filtek Supreme XT (p=0.028). The difference in the microhardness values between before and after bleaching using Treswhite Supreme was statistically significant only for Premise (p=0.022). High-concentration carbamide peroxide–containing home bleaching may affect the microhardness of restorative materials.
Polytherm of the CO(NH2)2-KNO3-H2O phase diagram
NASA Astrophysics Data System (ADS)
Yulina, I. V.; Trunin, A. S.
2017-05-01
The crystallization polytherm of the ternary CO(NH2)2-KNO3-H2O system is plotted for the first time via visual polythermal analysis and calculating ternary eutonics characteristics from data on the boundary elements of two-component systems. The ternary eutonics modeling error does not exceed 3.5%. In addition to the crystallization fields of individual components, the field of the redox reaction that occurs in the system between potassium nitrate and carbamide is shown in the CO(NH2)2-KNO3-H2O diagram by a dashed outline.
Wang, Xiao-ling; Xu, Juan; Zhao, Xin-yi; He, Hui-ming
2011-01-01
To evaluate the effect of carbamide peroxide (CP) bleaching agents at different concentrations and with different carriers on the micro-leakage of composite resin interface. Class V cavity (2 mm in diameter and 2 mm in depth) preparations were made at the enamelo-cemental junction on the buccal and lingual surfaces of 35 extracted human premolars. The cavities were filled with hybrid composite resin. The teeth were stored for 24 h in distilled water at 37 degrees celsius; before thermocyling for 500 times between 5 and 55 degrees celsius;. The teeth were then randomly assigned into 7 groups, and in groups 1-6, the bleaching gels containing 10% or 20% of CP were applied on the buccal and lingual surface of the teeth for two weeks (6-8 h/day, 37 degrees celsius;, 100% relative humidity) using Carbopol, PVP or Poloxamer as the thickening carriers, respectively. The seventh group served as the control without bleaching treatment. Nail polish was applied to the surface of the tooth, and all the teeth were immersed in ammoniacal silver nitrate solution followed by developing solution. The teeth were finally sectioned through the midline of the restoration and observed under stereomicroscope. SEM micrographs were also made to observe the interface. With the same bleaching agent, the micro-leakage in the gingival wall was slightly greater than in the occlusive wall, but the difference was not significant. Only 20% CP with Poloxamer as the thickening agent significantly increased the leakage of dentine-resin composite interface, and 10% and 20% CP with Carbopol or PVP as the thickening agents and 10% CP with Poloxamer produced minimal effects on filling the micro-leakage. Thickening carriers and the concentration of CP (20% or below) have no significant effect on micro-leakage of composite resin.
Oliveira, Jbs; Sarlo, R S; Bresciani, E; Caneppele, Tmf
The aim of this study was to compare the effectiveness of whitening mouth rinses on teeth previously whitened or not, exposed to food dyes. One hundred twenty enamel-dentin specimens, 3 mm in diameter, were obtained from bovine incisors. The specimens were stained for 14 days in staining broth. After staining, the initial color reading was performed via a spectrophotometer CM-2600d (Konica Minolta). Half of specimens were submitted to whitening (10% carbamide peroxide [CP]) for 14 days. They were then divided into three groups and were submitted to cycles of staining (five minutes) and mouth rinses (two minutes) for 12 weeks, with the following: CP-LI, Listerine Whitening; CP-PL, Plax Whitening; CP-BP, bromelain + papain; CP-DW, deionized water. LI, PL, BP, and DW groups were submitted to the same cited cycles but with no prior bleaching. The color measurements were performed after four, eight, and 12 weeks of treatment with mouth rinses. Data were submitted to repeated measures analysis of variance (ANOVA) and Tukey's test for multiple comparisons, with significance level at 5%. The results showed that the CP-LI, CP-PL, LI, and PL groups had greater color change than did the others. The CP-BP and BP groups were similar to CP-DW and DW. We therefore conclude that Listerine Whitening mouth rinse presented the highest bleaching effect, followed by Plax Whitening mouth rinse. Both maintained CP bleaching effect after 12 weeks of dye-rinse cycles. However, none of these rinses were able to produce whitening similar to CP. Bromelain- and papain-containing mouth rinses did not show bleaching effect, being similar to the control groups.
Saladi, Hari Krishna; Bollu, Indira Priyadarshini; Burla, Devipriya; Ballullaya, Srinidhi Vishnu; Devalla, Srihari; Maroli, Sohani; Jayaprakash, Thumu
2015-01-01
Introduction The bond strength of the composite to the bleached enamel plays a very important role in the success and longevity of an aesthetic restoration. Aim The aim of this study was to compare and evaluate the effect of Aloe Vera with 10% Sodium Ascorbate on the Shear bond strength of composite resin to bleached human enamel. Materials and Methods Fifty freshly extracted human maxillary central incisors were selected and divided into 5 groups. Group I and V are unbleached and bleached controls groups respectively. Group II, III, IV served as experimental groups. The labial surfaces of groups II, III, IV, V were treated with 35% Carbamide Peroxide for 30mins. Group II specimens were subjected to delayed composite bonding. Group III and IV specimens were subjected to application of 10% Sodium Ascorbate and leaf extract of Aloe Vera following the Carbamide Peroxide bleaching respectively. Specimens were subjected to shear bond strength using universal testing machine and the results were statistically analysed using ANOVA test. Tukey (HSD) Honest Significant Difference test was used to comparatively analyse statistical differences between the groups. A p-value <0.05 is taken as statistically significant. Results The mean shear bond strength values of Group V showed significantly lower bond strengths than Groups I, II, III, IV (p-value <0.05). There was no statistically significant difference between the shear bond strength values of groups I, II, III, IV. Conclusion Treatment of the bleached enamel surface with Aloe Vera and 10% Sodium Ascorbate provided consistently better bond strength. Aloe Vera may be used as an alternative to 10% Sodium Ascorbate. PMID:26674656
Adebayo, O A; Burrow, M F; Tyas, M J
2007-11-01
To evaluate (a) the enamel microshear bond strength (MSBS) of a universal adhesive and (b) the effects of conditioning with a self-etching primer adhesive with/without prior bleaching and/or casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) application. Thirty-five molars were cut into four sections, assigned randomly to four groups (no treatment; 16% carbamide peroxide bleaching; CPP-ACP-containing paste (Tooth Mousse, TM); bleaching and TM) and treated accordingly. Specimens were divided into two for bonding with either a self-etching primer (Clearfil SE Bond, CSE) or a total-etch adhesive (Single Bond, SB). Specimens for CSE bonding were subdivided for one of four preconditioning treatments (no conditioning; 30-40% phosphoric acid (PA); 15% EDTA; 20% polyacrylic acid conditioner (Cavity conditioner, CC) and treated. The adhesives were applied and resin composite bonded to the enamel using microtubes (internal diameter 0.75mm). Bonds were stressed in shear until failure, mean MSBS calculated and data analysed using ANOVA with Tukey's HSD test (alpha=0.05). The modes of bond failure were assessed and classified. Two-way ANOVA revealed significant differences between treatments (P<0.0001), conditioners (P<0.0001) and a significant interaction between treatments and conditioners (P=0.001). One-way ANOVA revealed no significant differences in MSBS following any of the treatments for SB; following TM application for CSE without preconditioning; and significant differences in MSBS following bleaching with and without TM application for CSE. With preconditioning, applying PA before CSE post-bleaching and either PA or CC before CSE post-TM application, resulted in significant differences in MSBS (P<0.05). The use of conditioners prior to bonding with the self-etching primer adhesive system on treated enamel may significantly improve bond strengths.
A model for prediction of color change after tooth bleaching based on CIELAB color space
NASA Astrophysics Data System (ADS)
Herrera, Luis J.; Santana, Janiley; Yebra, Ana; Rivas, María. José; Pulgar, Rosa; Pérez, María. M.
2017-08-01
An experimental study aiming to develop a model based on CIELAB color space for prediction of color change after a tooth bleaching procedure is presented. Multivariate linear regression models were obtained to predict the L*, a*, b* and W* post-bleaching values using the pre-bleaching L*, a*and b*values. Moreover, univariate linear regression models were obtained to predict the variation in chroma (C*), hue angle (h°) and W*. The results demonstrated that is possible to estimate color change when using a carbamide peroxide tooth-bleaching system. The models obtained can be applied in clinic to predict the colour change after bleaching.
City sewer collectors biocorrosion
NASA Astrophysics Data System (ADS)
Ksiażek, Mariusz
2014-12-01
This paper presents the biocorrosion of city sewer collectors impregnated with special polymer sulphur binders, polymerized sulphur, which is applied as the industrial waste material. The city sewer collectors are settled with a colony of soil bacteria which have corrosive effects on its structure. Chemoautotrophic nitrifying bacteria utilize the residues of halites (carbamide) which migrate in the city sewer collectors, due to the damaged dampproofing of the roadway and produce nitrogen salts. Chemoorganotrophic bacteria utilize the traces of organic substrates and produce a number of organic acids (formic, acetic, propionic, citric, oxalic and other). The activity of microorganisms so enables the origination of primary and secondary salts which affect physical properties of concretes in city sewer collectors unfavourably.
Dental whitening--revisiting the myths.
Perdigão, Jorge
2010-01-01
The popularity of dental bleaching has increased with the introduction of at-home whitening. Currently available whitening methods include those prescribed by a dental professional for use at home, those applied by the professional in the dental office, a combination of the two, or systems available over the counter. This article reviews the effect, efficacy, and safety of bleaching techniques and materials. Most whitening techniques are considered effective and safe when carried out under the supervision of a dental professional. This article also compares the efficacy and safety of some of the most popular bleaching techniques, including at-home whitening with carbamide peroxide, over-the-counter (OTC) systems, and in-office whitening. Some of these whitening techniques are illustrated in this article.
Swarupa, V; Chaudhury, A; Krishna Sarma, P V G
2017-03-01
The present study aimed to investigate the anti-Staphylococcus aureus and anti-biofilm properties of 4-methoxy-1-methyl-2-oxopyridine-3-carbamide (MMOXC) on S. aureus UDP-MurNAc-pentapeptide (MurF), peptidyl deformylase (PDF) and uridine monophosphate kinase (UMPK). The in vitro efficacy of MMOXC was evaluated using quantitative polymerase chain reaction, in vitro assays and broth microdilution methods. Further, the minimum inhibitory concentration (MIC), IC 50 and zone of inhibition were recorded in addition to the anti-biofilm property. MMOXC inhibited pure recombinant UMPK and PDF enzymes with a K i of 0·37 and 0·49 μmol l -1 . However K i was altered for MurF with varying substrates. The MurF K i for UMT, d-Ala-d-Ala and ATP as substrates was 0·3, 0·25 and 1·4 μmol l -1 , respectively. Real-time PCR analysis showed a significant reduction in PDF and MurF expression which correlated with the MIC 90 at 100 μmol l -1 and IC 50 in the range 42 ± 1·5 to 50 ± 1 μmol l -1 against all strains tested. At 5 μmol l -1 MMOXC was able completely to remove preformed biofilms of S. aureus and other drug resistant strains. MMOXC was able to kill S. aureus and drug resistant strains tested by inhibiting MurF, UMPK and PDF enzymes and completely obliterated preformed biofilms. Growth reduction and biofilm removal are prerequisites for controlling S. aureus infections. In this study MMOXC exhibited prominent anti-S. aureus and anti-biofilm properties by blocking cell wall formation, RNA biosynthesis and protein maturation. © 2016 The Society for Applied Microbiology.
Fatima, Nazish
2016-01-01
To evaluate the effect of home-use bleaching agent containing 16% Carbamide Peroxide (CP) and in-office bleaching agent with 38% Hydrogen Peroxide (HP) on surface micro-morphology of enamel. An experimental study. The discs were prepared at Material Engineering Department of NED University of Engineering and Technology, Karachi, and surface morphology was analyzed at Centralized Science Laboratory of Karachi University, Pakistan. Duration of study was one year from January to December 2012. Forty five sound human third molar crowns, extracted for periodontal reason, were included in the study. Longitudinal sections were made using diamond disks (0.2 mm) under water lubrication to obtain enamel slabs measuring (3 mm x 3 mm). The slabs were embedded in polystyrene resin by using 2.0 cm diameter PVC molds, leaving the outer enamel surface uncovered by the resin. Ninety dental enamel slabs were prepared. The slabs were then randomly divided into 3 groups. Each group contained thirty specimens (n=30). Group 1 was kept in artificial saliva at 37°C in incubator (Memart, Germany) during whole experiment. Group 2 was treated with power whitening gel (White Smile 2011, Germany). Group 3 was treated with tooth whitening pen (White Smile 2011, Germany). The most central region or the region that was most representative of the entire surface area was used. The SEM (Jeol-Japan-JSM6380A, JAPAN) micrographs were examined to determine the type of surface presented. The enamel changes were classified as no or mild alteration, moderate alteration and severe altered surface. Regarding micro-morphology, the enamel surface of control groups showed smooth surface in general with some scattered clear scratches due to the polishing procedure. The specimens bleached in group 2 and group 3, represented areas of mild erosion. Bleaching with 38% Hydrogen Peroxide (HP) and 16% Carbamide Peroxide (CP) resulted in mild changes in surface micro-morphology of enamel.
Effect of various tooth-whitening products on enamel microhardness.
Grobler, S R; Majeed, A; Moola, M H
2009-11-01
The purpose of this in vitro study was to evaluate the effect of various tooth-whitening products containing carbamide peroxide (CP) or hydrogen peroxide (HP), on enamel microhardness. Enamel blocks were exposed to: Nite White ACP 10% CP (Group 2, n=10); Yotuel Patient 10% CP (Group 3, n=10); Opalescence PF 10% CP (Group 4, n=10); Opalescence PF 20% CP (Group 5, n=10); Opalescence Treswhite Supreme 10% HP (Group 6, n=10); Yotuel 10 Minutes 30% CP (Group 7, n=10); Opalescence Quick 45% CP (Group 8, n=10), Yotuel Special 35% HP (Group 9, n=10), Opalescence Boost 38% HP (Group 10, n=10) according to the instructions of the manufacturers. The control (Group 1, n=10) was enamel blocks kept in artificial saliva at 37 degrees C without any treatment. The microhardness values were obtained before exposure and after a 14-day treatment period. Specimens were kept in artificial saliva at 37 degrees C between treatments. Data were analysed using Kruskal-Wallis one-way ANOVA and Tukey-Kramer Multiple Comparison Test. Indent marks on the enamel blocks were also examined under the Scanning Electron Microscope. All whitening products decreased enamel microhardness except group 10 but only Groups 2, 3, 4, 5 and 7 showed significant decrease in enamel microhardness as compared to the control group (p < 0.05). Groups 2, 3 and 7 differed significantly from all the other groups (p < 0.05). The highest damage was recorded for Group 2 (Nite White ACP 10% CP), which differed significantly from Groups 3 and 7. SEM images also showed damage to enamel. All products tested in this study decreased enamel microhardness except Opalescence Boost 38% HP. The products containing carbamide peroxide were more damaging to enamel because of the longer application times. Nite White ACP 10% CP showed the highest reduction in enamel microhardness as compared to other products tested.
Aka, Betül; Celik, Esra Uzer
2017-09-01
This randomized controlled clinical trial compared the bleaching efficacy of two different at-home bleaching systems on teeth of different shades and their color stability after a 6-month follow-up. Ninety-two patients (777 teeth) were randomly divided into three groups: (a) negative control, (b) patients treated with a custom-made tray containing 10% carbamide peroxide (10% CP/PF) (Opalescence PF), and (c) patients treated with a pre-loaded tray containing 6% hydrogen peroxide (6% HP/Go) (Opalescence Go). Teeth in all groups were divided into three sub-groups according to the VITA Classic Shade Guide: light (A1-C1), medium dark (C2-B3), and dark (A3.5-C4). Bleaching systems were performed in accordance with manufacturers' instructions for 14 days. The color values were measured at the baseline, 10 days and 14 days of bleaching, 2 weeks, and 6 months after bleaching. Three-way ANOVA and Mann-Whitney U tests were used for statistical analysis (α = 0.05). Irrespective of original shade, both bleaching groups showed significantly higher ΔE* values than the control groups, and the ΔE* values were significantly higher in the 10% CP/PF groups than those in the 6% HP/Go groups (p < 0.05). In both bleaching systems, the dark teeth showed higher ΔE* values than the light teeth (p < 0.05). The ΔE* values decreased significantly only in the 10% CP/PF groups after 6 months (p < 0.05). Both bleaching agents produced a bleaching effect, but 10% CP/PF was more effective. A pre-loaded tray system may be used for dental bleaching, but it is still less effective than conventional a 10% carbamide peroxide system, irrespective of the initial shade. (J Esthet Restor Dent 29:325-338, 2017). © 2017 Wiley Periodicals, Inc.
Stain removal effect of novel papain- and bromelain-containing gels applied to enamel.
Münchow, Eliseu A; Hamann, Henry J; Carvajal, M Teresa; Pinal, Rodolfo; Bottino, Marco C
2016-11-01
The aims of the study are to prepare novel stain removal gel-based formulations containing papain or bromelain and to investigate their stain removal effect when applied to enamel. Experimental bromelain- and papain-based stain removal gels were prepared. Next, enamel/dentin tooth samples (6 × 6 mm 2 , 4 mm in thickness) were obtained from bovine teeth, stained in coffee solution for 1 week, and measured with a digital spectrophotometer (Easyshade, Vita Zahnfabrik) for color assessment (baseline). The samples were then randomly allocated into four groups (n = 7), according to the stain removal agent applied: ContrastPM+ (Discus Dental, LLC), which is based on 20 wt.% carbamide peroxide (positive control); bromelain-based; papain-based; and no agent (negative control). The materials were applied once a week, three times per day, during 4 weeks, and following the directions of use from positive control. The samples were measured again with the Easyshade and using the CIEL * a * b * color system. The color change (ΔE * ) results were obtained by subtracting the baseline values from the final color values obtained at each time point. The data were statistically analyzed using two-way repeated-measures analysis of variance and Student Newman Keuls's test as a post hoc test (α = 5 %). All stain removal agents produced greater color change than the negative control (p < .001), with the positive control demonstrating greater ΔE * values when compared to the experimental gels (p ≤ .004). The second application of all gels resulted in greater ΔE * values compared to the first application (p ≤ .025), although no color change was observed after the third application (p ≥ .051), regardless of the material evaluated. The proposed gels containing proteolytic enzymes (bromelain or papain) of vegetal origin may hold significant clinical potential as active agents for the preparation of stain removal agents free of hydrogen/carbamide peroxide.
Comparative trial of serotonin antagonists in the management of migraine.
Lance, J W; Anthony, M; Somerville, B
1970-05-09
The effectiveness of five different serotonin antagonists in the prevention of migraine was compared in 290 patients followed for periods of up to three years. Methysergide 3-6 mg. daily was most effective, with 20% of treated patients becoming headache-free and a further 44% remaining more than "half improved." The corresponding figures for BC105 were 10% and 40%, respectively.The results with BC105 were significantly better than those with placebo (P<0.02). The total improvement rates with methdilazine (45%) and cyproheptadine (43%) were better than those with placebo (32%) but did not achieve statistical significance. A new preparation, methylergol carbamide maleate, which is chemically related to methysergide, did not give better results than placebo.
Amorphous Silica Micro Powder Additive Influence on Tensile Strength of One-Ply Particle Board
NASA Astrophysics Data System (ADS)
Pitukhin, A. V.; Kolesnikov, G. N.; Panov, N. G.; Vasilyev, S. B.
2018-03-01
The methods and results of experimental investigation on the additive influence of amorphous silica micro powder when mixed in the glue for one-ply particle board are presented in the article. Wooden particles of coniferous and hardwood species as well as glue solution based on carbamide-formaldehyde resin were used for boards manufacturing. The amorphous silica micro powder contained particles on the average 8 μm by the size and specific surface 120…400 m2/g was used in experiment. The samples were tested to determine their physical-mechanical properties. It was found that 1 % amorphous silica micro powder additive increases the breaking point of one-ply particle board under tensile stress by 143 %.
Micro-structural integrity of dental enamel subjected to two tooth whitening regimes.
Tanaka, Reina; Shibata, Yo; Manabe, Atsufumi; Miyazaki, Takashi
2010-04-01
Colour modification of tooth enamel has proven successful, but it is unclear how various bleaching applications affect micro-structural integrity of the whitened enamel. To investigate the internal structural integrity of human intact tooth enamel with the application of two commonly used whitening regimes (in-office power bleaching with 35% hydrogen peroxide and home bleaching with 10% carbamide peroxide), evaluations were performed on teeth of identical colour classification. After the bleaching applications, the enamel mineral density was quantified and visualised with micro-computed tomography. The micro-structural differences between the whitened tooth enamel samples were distinctive, though the colour parameter changes within the samples were equivalent. Home bleaching achieved colour modification by demineralisation, whereas in-office bleaching depended on redistribution of the minerals after treatment and subsequent enhanced mineralisation.
Effect of bleaching agents and soft drink on titanium surface topography.
Faverani, Leonardo P; Barão, Valentim A R; Ramalho-Ferreira, Gabriel; Ferreira, Mayara B; Garcia-Júnior, Idelmo R; Assunção, Wirley G
2014-01-01
The effects of carbamide peroxide, hydrogen peroxide and cola soft drink on the topographic modifications of commercially-pure titanium (CP-Ti) and Ti-6Al-4V were investigated. Ti discs were divided into 18 groups (n = 4) based on the solution treatment and Ti type. Specimens were immersed in 3 mL of each solution for 4 h per day (for the remaining 20 h, discs were left dry or immersed in artificial saliva) for 15 days. For control, specimens were immersed in only artificial saliva. Ti surfaces were examined using scanning electron (SEM) and atomic force (AFM) microscopes and their surface roughness (in µm) and surface chemical modifications were investigated. Data were analyzed by ANOVA and Tukey's test (α = 0.05). Groups immersed in 35% hydrogen peroxide showed the highest roughness (Ra) (171.65 ± 4.04 for CP-Ti and 145.91 ± 14.71 for Ti-6Al-4V) (p < 0.05), followed by groups treated with carbamide peroxide 16% (110.91 ± 0.8 for CP-Ti and 49.28 ± 0.36 for Ti-6Al-4V) and 35% (65.67 ± 1.6 for CP-Ti and 53.87 ± 1.98 for Ti-6Al-4V); treatment with artificial saliva did not affect the results. These values were statistically superior to those observed prior to the treatment and to those of the control group (31.0 ± 0.99 for CP-Ti and 29.95 ± 0.58 for Ti-6Al-4V). Cola soft drink did not alter the surface roughness of either Ti type (p > 0.05). SEM and AFM revealed dramatic changes in the specimens surfaces immersed in the 35% hydrogen peroxide, mainly for CP-Ti. No detectable chemical modifications on the Ti surface were observed. Bleaching agents promoted significant changes in Ti topography, which could affect the longevity of implants treatments. Copyright © 2013 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Murthy, P. Krishna; Sheena Mary, Y.; Shyma Mary, Y.; Panicker, C. Yohannan; Suneetha, V.; Armaković, Stevan; Armaković, Sanja J.; Van Alsenoy, C.; Suchetan, P. A.
2017-04-01
4-benzyl-5-oxomorpholine-3-carbamide has been synthesized; single crystals were grown by slow evaporation solution growth technique at room temperature and characterized by single crystal X-ray diffraction, FT-IR, FT-Raman and 1H-NMR. The compound crystallizes in the monoclinic space group P21/n. The molecular geometry of the compound was optimized by using Density Functional Theory (DFT/B3LYP) method with 6-311++G(d,p) basis set in the ground state and geometric parameters are in agreement with the X-ray analysis results of the structure. The experimental vibrational spectra were compared with the calculated spectra and each vibrational wave number was assigned on the basis of potential energy distribution (PED). The electronic and charge transfer properties have been explained on the basis of highest occupied molecular orbital's (HOMOs) and lowest unoccupied molecular orbital's (LUMOs). Besides molecular electrostatic potential (MEP), frontier molecular orbital's (FMOs), some global reactivity descriptors, thermodynamic properties, non-linear optical (NLO) behavior and Mullikan charge analysis of the title compound were computed with the same method in gas phase, theoretically. Potential reactive sites of the title compound have been identified by average local ionization energy and Fukui functions, both mapped to the electron density surface. Bond dissociation energies for all single acyclic bonds have been calculated in order to investigate autoxidation and degradation properties of the title compound. Atoms with pronounced interactions with water molecules have been detected by calculations of radial distribution functions after molecular dynamics simulations. The experimental results are compared with the theoretical calculations using DFT methods for the fortification of the paper. Further the docking studies revealed that the title compound as a docked ligand forms a stable complex with pyrrole inhibitor with a binding affinity value of -7.5 kcal/mol. This suggests that the title compound might exhibit inhibitory activity against pyrrole inhibitor. To confirm the potential practical applicability of the title compound antimicrobial activity was tested against gram negative and gram positive bacteria.
Dielectrophoresis enhances the whitening effect of carbamide peroxide on enamel.
Ivanoff, Chris S; Hottel, Timothy L; Garcia-Godoy, Franklin; Riga, Alan T
2011-10-01
To compare the enamel whitening effect of a 20-minute dielectrophoresis enhanced electrochemical delivery to a 20-minute diffusion treatment. Forty freshly extracted human teeth without detectable caries or restoration were stored in distilled water at 4 degrees C and used within 1 month of extraction. Two different bleaching gels (Plus White 5 Minute Speed Whitening Gel and 35% Opalescence PF gel) were tested. The study had two parts: Part 1--Quantitative comparison of hydrogen peroxide (H2O2, HP) absorption--following application of an over-the-counter 35% HP whitening gel (Plus White 5 Minute Speed Whitening Gel) to 30 (n = 30) extracted human teeth by conventional diffusion or dielectrophoresis. The amount of H2O2 that diffused from the dentin was measured by a colorimetric oxidation-reduction reaction kit. HP concentration was measured by UV-Vis spectroscopy at 550 nm. Part 2--HP diffusion in stained teeth--35% carbamide peroxide whitening gel (35% Opalescence PF gel) was applied to 10 extracted human teeth (n = 10) stained by immersion in a black tea solution for 48 hours. The teeth were randomly assigned to the 20-minute dielectrophoresis or diffusion treatment group; whitening was evaluated by a dental spectrophotometer and macro-photography. Part 1: The analysis found significant differences between both groups with relative percent errors of 3% or less (a single outlier had an RPE of 12%). The average absorbance for the dielectrophoresis group in round 1 was 79% greater than the diffusion group. The average absorbance for the dielectrophoresis group in round 2 was 130% greater than the diffusion group. A single-factor ANOVA found a statistically significant difference between the diffusion and dielectrophoresis groups (P = 0.01). Part 2--The average change in Shade Guide Units (SGU) was 0.6 for the diffusion group, well under the error of measurement of 0.82 SGU. The average change in SGU for the dielectrophoresis group was 9, significantly above the error of measurement and 14 times or 1,400% greater than the diffusion group average. A single-factor ANOVA found a statistically significant difference between the diffusion and dielectrophoresis treatment groups (P < 0.001).
Efficacy of hydrogen-peroxide-based mouthwash in altering enamel color.
Jaime, Ivone Maria de Lima; França, Fabiana Mantovani Gomes; Basting, Roberta Tarkany; Turssi, Cecilia Pedroso; Amaral, Flávia Lucisano Botelho
2014-02-01
To analyze the efficacy of Colgate Plax Whitening mouthwash containing 1.5% hydrogen peroxide. 30 enamel fragments, obtained from the proximal surfaces of human third molars were darkened with Orange II methyl orange. The fragments were divided into three groups according to the type of bleaching agent applied (n = 10): (1) 10% carbamide peroxide gel (positive control, PC) was applied for 2 hours/day for 28 days; (2) a solution containing 1.5% hydrogen peroxide (Plax) was applied for 4 minutes once a day for 28 days, and (3) no bleaching agent, kept in artificial saliva (negative control, AS). The specimens were kept in artificial saliva between treatment intervals. The specimens were photographed before darkening (baseline), after darkening and before lightening and on the 28th day of whitening. Afterwards, they were analyzed with color measurement software using the CIELab system. The data for the L*, a* and b* parameters were submitted to two-way ANOVA with repeated measures. The values of deltaL *, deltaa *, deltab * and deltaE* were calculated using two procedures: (1) darkened versus original, and (2) bleached versus darkened. This data was submitted to the one-way ANOVA test. Multiple comparisons were conducted using the Tukey test (alpha = 0.05). When the specimens were subjected to bleaching agents, there was a significant increase in the brightness (L* parameter) of the enamel exposed to the gel and also to the bleaching solution. However, higher brightness was observed for the PC (gel) group. As for the axis a* parameters, there were no significant differences between the bleaching products. Regarding the axis b* parameters, the PC group underwent major changes (indicating a color change toward blue chroma), statistically greater than those of the Plax group. After bleaching, there was a significantly greater color change (deltaE*) in the PC group. Although the Plax solution caused a color change, it was less than that produced by the gel. The slightest color change was observed in the control group, in which no bleach was used. The mouthwash containing hydrogen peroxide was able to lighten the darkened human enamel, but to a lesser degree than the lightening produced by 10% carbamide peroxide.
A clinical evaluation of 10 percent vs. 15 percent carbamide peroxide tooth-whitening agents.
Kihn, P W; Barnes, D M; Romberg, E; Peterson, K
2000-10-01
Agents with carbamide peroxide, or CP, in various concentrations are widely prescribed for at-home tooth whitening. It is not clear, however, if the more concentrated gels will whitening teeth to a greater extent, as no controlled clinical trials have been reported. The authors conducted a double-blind study of human subjects to evaluate whether a 15 percent CP tooth-whitening system was more effective than a 10 percent CP system, and to determine if tooth sensitivity increased with use of the higher concentration. The authors recruited 57 subjects with maxillary anterior teeth of shade A3 or darker (as gauged against a value-oriented shade guide). The subjects were 18 to 65 years of age and in good general and dental health. After matching the subjects by sex and age, the authors randomly assigned them to either a control group, which used a 10 percent CP whitening agent, or an experimental group, which used a 15 percent CP agent. The results indicated that there was no significant difference in shade change between the groups after one week of treatment (t = 1.455, P = .05), but there was a significant difference at the end of the treatment period (t = 2.303, P < .05), as well as two weeks after treatment concluded (t = 2.248, P < .05). There was no significant difference in sensitivity (t = 1.399, P > .05). There was a significant difference in color change between the 10 percent CP and 15 percent CP groups at the end of the study period. There was no significant difference in level of tooth sensitivity between the two groups, and the incidence was equal; there was, however, a significant difference in variability of tooth sensitivity between the two groups. If performed under the careful guidance of a dentist, at-home whitening is an effective treatment, regardless of whether 10 percent CP or 15 percent CP is used. There may be added color change and varying sensitivity with the use of 15 percent CP.
Double-blind whitening Night-Guard study using ten percent carbamide peroxide.
Ouellet, D; Los, S; Case, H; Healy, R
1992-01-01
The conservative technique of professionally dispensed and supervised, home-administered vital bleaching is now a routine treatment in the dental profession. This double-blind study evaluated the Rembrandt Lightening Gel and Whitening Toothpaste for shade change, colorimeter shade change. As well, it evaluated soft tissue health by periodontal probing, plaque index, and bleeding index. A patient questionnaire evaluated perception of whitening, perception of oral hygiene, average hours per day, and average days per week. Bleaching trays were worn over a 4-week period. The bleaching system showed definitive whitening effects as evaluated with the Vita shade guide and the colorimeter. The bleaching system had no deleterious effects on the soft tissue. The Rembrandt toothpaste alone demonstrated two-shade lightening. This vital bleaching system shows definitive whitening of the teeth in short periods of time with no adverse effects.
Perdigão, J; Lam, V Q; Burseth, B G; Real, C
This clinical report illustrates a conservative technique to mask enamel discolorations in maxillary anterior teeth caused by hypomineralization associated with enamel fluorosis and subsequent direct resin composite to improve the anterior esthetics. The treatment consisted of at-home whitening with 10% carbamide peroxide gel with potassium nitrate and sodium fluoride in a custom-fitted tray to mask the brown-stained areas, followed by resin infiltration to mask the white spot areas. An existing resin composite restoration in the maxillary right central incisor was subsequently replaced after completion of the whitening and resin infiltration procedures, whereas the two misaligned and rotated maxillary lateral incisors were built up with direct resin composite restorations to provide the illusion of adequate arch alignment, as the patient was unable to use orthodontic therapy.
Rapid analysis of fertilizers by the direct-reading thermometric method.
Sajó, I; Sipos, B
1972-05-01
The authors have developed rapid methods for the determination of the main components of fertilizers, namely phosphate, potassium and nitrogen fixed in various forms. In the absence of magnesium ions phosphate is precipitated with magnesia mixture; in the presence of magnesium ions ammonium phosphomolybdate is precipitated and the excess of molybdate is reacted with hydrogen peroxide. Potassium is determined by precipitation with silico-fluoride. For nitrogen fixed as ammonium salts the ammonium ions are condensed in a basic solution with formalin to hexamethylenetetramine; for nitrogen fixed as carbamide the latter is decomposed with sodium nitrite; for nitrogen fixed as nitrate the latter is reduced with titanium(III). In each case the temperature change of the test solution is measured. Practically all essential components of fertilizers may be determined by direct-reading thermometry; with this method and special apparatus the time of analysis is reduced to at most about 15 min for any determination.
Fuel additives and heat treatment effects on nanocrystalline zinc ferrite phase composition
NASA Astrophysics Data System (ADS)
Hu, Ping; Pan, De-an; Wang, Xin-feng; Tian, Jian-jun; Wang, Jian; Zhang, Shen-gen; Volinsky, Alex A.
2011-03-01
Nanocrystalline ZnFe 2O 4 powder was prepared by the auto-combustion method using citric acid, acetic acid, carbamide and acrylic acid as fuel additives. Pure spinel zinc ferrite with the crystallite size of about 15 nm can be obtained by using acrylic acid as fuel additive. Samples prepared using other fuel additives contain ZnO impurities. In order to eliminate ZnO impurities, the sample prepared with citric acid as fuel additive was annealed at different temperatures up to 1000 °C in air and in argon. Annealed powders have pure ZnFe 2O 4 phase when annealing temperature is higher than 650 °C in air. Sample annealed at 650 °C in air is paramagnetic. However, annealed powders become a mixture of Fe 3O 4 and FeO after annealing at 1000 °C in argon atmosphere due to Zn volatility and the reduction reaction.
In Vitro Comparative Study of Two Different Bleaching Agents on Micro-hardness Dental Enamel.
Fatima, Nazish; Ali Abidi, Syed Yawar; Meo, Ashraf Ali
2016-02-01
To evaluate the effect of home-use bleaching agent containing 16% Carbamide Peroxide (CP) and in-office bleaching agent containing 38% Hydrogen Peroxide (HP) on enamel micro-hardness. An in vitroexperimental study. Department of Operative Dentistry and Science of Dental Materials at Dr. Ishrat-ul-Ebad Khan Institute of Oral Health Sciences, Dow University of Health Sciences and Material Engineering Department of NED University of Engineering and Technology, Karachi, from July to December 2014. Atotal of 90 enamel slabs from 45 sound human 3rd molar were randomly divided into 3 groups. Each group contained 30 specimens (n=30). Group 1 was kept in artificial saliva at 37°C in incubator during the whole experiment. However, Groups 2 and 3 were treated with power whitening gel and tooth whitening pen respectively. After bleaching session, specimens were thoroughly rinsed with deionized water again for 10 seconds and then stored in artificial saliva at 37°C in incubator. Artificial saliva was changed after every 2 days. The Vickers hardness tester (Wolpert 402 MVD, Germany) was adjusted to a load of 0.1 kg (100 gm) and dwell time of 5 seconds. Three Vickers were performed on each specimen using a hardness tester according to the ISO 6507-3:1998 specification. Micro-hardness measurements were performed before and after bleaching at day 1, 7 and 14. In the control group, the baseline micro-hardness was 181.1 ±9.3 which was reduced after the storage on day 1, 7 and 14 (p = 0.104). In Group 2, baseline micro-hardness was 180.4 ±10.1 which was reduced to 179.79 ±10.0 units after day 1. Whereas, on day 7 and 14, the values of micro-hardness were 179.8 ±10 and 179.7 ±10.29, respectively (p=0.091). Furthermore, the baseline micro-hardness in Group 3 was 174.0 ±22.9 units which was reduced to 173 ±23 on day 1, 170 ±30 on day 7 and 173 ±23 on day 14 (p = 0.256). The statistically insignificant difference was found among micro-hardness values of different bleaching agents (p = 0.118). Bleaching with 38% Hydrogen Peroxide (HP) and 16% Carbamide Peroxide (CP) resulted in insignificant effect on surface micro-hardness of enamel.
Preparation of Titanium nitride nanomaterials for electrode and application in energy storage
NASA Astrophysics Data System (ADS)
Tang, Shun; Cheng, Qi; Zhao, Jinxing; Liang, Jiyuan; Liu, Chang; Lan, Qian; Cao, Yuan-Cheng; Liu, Jiyan
The Titanium nitride was made by the carbamide and titanic chloride precursors. XRD results indicate that the precursor ratio N:Ti 3:1 leads to higher crystallinity. SEM and EDX demonstrated that Ti and N elements were distributed uniformly with the ratio of 1:1. The TiN used as the electrode material for supercapacitor was also studied. The specific capacities were changed from 407 F.g-1 to 385 F.g-1, 364 F.g-1 and 312 F.g-1, when the current densities were changed from 1 A.g-1 to 2 A.g-1, 5 A.g-1 and 10 A.g-1, respectively. Chronopotentiometry tests showed high coulombic efficiency. Cycling performance of the TiN electrode was evaluated by CV at a scanning rate of 50 mV.s-1 for 20,000 cycles and there was about 9.8% loss. These results indicate that TiN is a promising electrode material for the supercapacitors.
Effect of bleaching agent and topical fluoride application on color and gloss of dental ceramics.
Pires-de-Souza, Fernanda de Carvalho Panzeri; Contente, Marta Maria Martins Giamatei; Alandia-Román, Carla Cecilia; Vicente, Sergio Augusto de Freitas; Tonani, Rafaella
2016-01-01
The aim of this study was to evaluate the effect of 16% carbamide peroxide and 1.23% acidulated phosphate fluoride application and their association with a change in color (ΔE*) and brightness of dental ceramic submitted to different finishing procedures. A total of 120 test specimens were fabricated and randomly divided into 3 groups (n = 40) according to the type of finishing: glazing; polishing; or polishing and glazing. Initial color and brightness readouts were taken, and the finished specimens were divided into groups (n = 10) according to the treatment to which they were submitted: fluoride; bleaching; bleaching and fluoride; or control. After this, final color and brightness readouts were taken. The type of polishing had no influence on ΔE* or brightness (P > 0.05). Regardless of which solution was used, a decrease in brightness occurred only for the group treated with bleach and fluoride (P < 0.05). The results showed the use of fluoride after bleaching may interfere with the esthetics of a restoration.
Hilgenberg, Sérgio Paulo; Pinto, Shelon Cristina Souza; Farago, Paulo Vitor; Santos, Fábio André; Wambier, Denise Stadler
2011-01-01
This in vitro study evaluated the physical-chemical characteristics of whitening toothpastes and their effect on bovine enamel after application of a bleaching agent (16% carbamide peroxide). Physical-chemical analysis was made considering mass loss by desiccation, ash content and pH of the toothpastes. Thirty bovine dental enamel fragments were prepared for roughness measurements. The samples were subjected to bleaching treatments and simulated brushing: G1. Sorriso Dentes Brancos (Conventional toothpaste), G2. Close-UP Whitening (Whitening toothpaste), and G3. Sensodyne Branqueador (Whitening toothpaste). The average roughness (Ra) was evaluated prior to the bleaching treatment and after brushing. The results revealed differences in the physical-chemical characteristics of the toothpastes (p < 0.0001). The final Ra had higher values (p < 0.05) following the procedures. The mean of the Ra did not show significant differences, considering toothpaste groups and bleaching treatment. Interaction (toothpaste and bleaching treatment) showed significant difference (p < 0.0001). The whitening toothpastes showed differences in their physical-chemical properties. All toothpastes promoted changes to the enamel surface, probably by the use of a bleaching agent.
The effect of light-activation sources on tooth bleaching
Baroudi, Kusai; Hassan, Nadia Aly
2014-01-01
Vital bleaching is one of the most requested cosmetic dental procedures asked by patients who seek a more pleasing smile. This procedure consists of carbamide or hydrogen peroxide gel applications that can be applied in-office or by the patient (at-home/overnight bleaching system). Some in-office treatments utilise whitening light with the objective of speeding up the whitening process. The objective of this article is to review and summarise the current literature with regard to the effect of light-activation sources on in-office tooth bleaching. A literature search was conducted using Medline, accessed via the National Library of Medicine Pub Med from 2003 to 2013 searching for articles relating to effectiveness of light activation sources on in-office tooth bleaching. This study found conflicting evidence on whether light truly improve tooth whitening. Other factors such as, type of stain, initial tooth colour and subject age which can influence tooth bleaching outcome were discussed. Conclusions: The use of light activator sources with in-office bleaching treatment of vital teeth did not increase the efficacy of bleaching or accelerate the bleaching. PMID:25298598
Effect of a New Bleaching Gel on Tooth Whitening.
Barry, T N; Bailey, C W; Ashcraft-Olmscheid, D; Vandewalle, K S
The purpose of this study was to compare the whitening efficacy of a novel bleaching agent containing a unique tribarrel hydremide-peroxide gel (KöR) with a traditional bleaching system of hydrogen peroxide or carbamide peroxide (Opalescence). Bovine incisors were mounted into a custom resin, arch-shaped mounting device. Four groups of 10 teeth were created using mounting devices containing five teeth each. The in-office and home bleaching gels of KöR and Opalescence were applied to the teeth alone and in trays to simulate a combination of in-office and home bleaching or home bleaching only. Spectrophotometer readings of L* a* b* were performed at baseline, the end of active bleaching (immediate), and three and six months postbleaching. Immediately postbleaching, the use of Opalescence gel resulted in greater change in ΔE* and Δb* (less yellow) for combined and home bleaching techniques compared with KöR. After six months, Opalescence had significantly greater ΔE* and Δb* compared with KöR for home bleaching only. There was no significant difference in ΔL* between Opalescence and KöR at any time period with either technique.
Effect of in-office bleaching agents on physical properties of dental composite resins.
Mourouzis, Petros; Koulaouzidou, Elisabeth A; Helvatjoglu-Antoniades, Maria
2013-04-01
The physical properties of dental restorative materials have a crucial effect on the longevity of restorations and moreover on the esthetic demands of patients, but they may be compromised by bleaching treatments. The purpose of this study was to evaluate the effects of in-office bleaching agents on the physical properties of three composite resin restorative materials. The bleaching agents used were hydrogen peroxide and carbamide peroxide at high concentrations. Specimens of each material were prepared, cured, and polished. Measurements of color difference, microhardness, and surface roughness were recorded before and after bleaching and data were examined statistically by analysis of variance (ANOVA) and Tukey HSD post-hoc test at P < .05. The measurements showed that hue and chroma of silorane-based composite resin altered after the bleaching procedure (P < .05). No statistically significant differences were found when testing the microhardness and surface roughness of composite resins tested (P > .05). The silorane-based composite resin tested showed some color alteration after bleaching procedures. The bleaching procedure did not alter the microhardness and the surface roughness of all composite resins tested.
Present and future technologies of tooth whitening.
Viscio, D; Gaffar, A; Fakhry-Smith, S; Xu, T
2000-01-01
Dental stains can be broadly classified as intrinsic or extrinsic. Intrinsic stains are a result of defects in tooth development, fluorosis, or acquired through the use of tetracycline. Extrinsic stains are localized mainly in the pellicle and are generated by the reaction between sugars and amino acids or acquired from the retention of exogenous chromophores in the pellicle. Three clinical methods are currently used for measuring stain removal and tooth whitening in the development of new whitening technologies: Lobene Stain Index, Shade Guide Color Change, and Minolta ChromaMeter. Professional tooth whitening products rely on proven technologies--35% hydrogen peroxide for in-office power bleaching or 10% to 15% carbamide peroxide for at-home bleaching--to reduce intrinsic stain and change the inherent tooth color. Over-the-counter tooth whitening products use a combination of surfactants, abrasives, anticalculus agents, and low levels of hydrogen peroxide to reduce extrinsic stain and help maintain tooth whiteness after professional treatment. Future technologies for whitening teeth could involve the use of activating agents to enhance the performance of hydrogen peroxide and natural enzymes.
Comparative clinical evaluation of two professional tooth-whitening products.
Kowitz, G M; Nathoo, S A; Wong, R
1994-01-01
A 2-week study was conducted to compare the tooth-whitening efficacy of two 10% carbamide peroxide products: Colgate Platinum Professional Toothwhitening System and Rembrandt Lighten Bleaching Gel. Fifty subjects were divided into two groups and assigned a product to use for 2 weeks. Change in tooth color was measured by reflectance spectroscopy at the initiation of study, at 1 week, and at 2 weeks into the study. Color change was calculated using the color-difference equation established by the Commission International de L'Eclairage. Results showed that Colgate Platinum was 62% more effective at tooth whitening after 1 week and 83% more effective after 2 weeks of treatment vs Rembrandt. At the termination of the study, the mean color difference (deltaE) for Colgate Platinum was 4.29 and 2.34 for Rembrandt. Statistical analysis demonstrated that the Colgate product is significantly superior at increasing tooth whiteness, increasing tooth lightness, reducing redness, and reducing yellowness. In this study, no adverse reactions were noted on clinical examination and none were reported by panelists with normal healthy dentition.
Sharma, Himanshu; Sharma, Divya S
Children/adolescent's orodental structures are different in anatomy and physiology from that of adults, therefore require special attention for bleaching with oxidative materials. Hydroxyl radical (OH . ) generation from bleaching agents has been considered directly related to both its clinical efficacy and hazardous effect on orodental structures. Nonetheless bleaching agents, indirectly releasing hydrogen peroxide (H 2 O 2 ), are considered safer yet clinically efficient. Apart from OH . , perhydroxyl radicals (HO 2 . ) too, were detected in bleaching chemistry but not yet in dentistry. Therefore, the study aims to detect the OH . and HO 2 . from bleaching agents with their relative integral value (RIV) using 31 P nuclear magnetic resonance ( 31 PNMR) spectroscope. Radicals were generated with UV light in 30% H 2 O 2 , 35% carbamide peroxide (CP), sodium perborate tetrahydrate (SPT) and; neutral and alkaline 30% H 2 O 2 . Radicals were spin-trapped with DIPPMPO in NMR tubes for each test agents as a function of time (0, 1, 2, 3min) at their original pH. Peaks were detected for OH . and HO 2 . on NMR spectrograph. RIV were read and compared for individual radicals detected. Only OH . were detected from acidic and neutral bleaching agent (30% acidic and neutral H 2 O 2 , 35%CP); both HO 2 . and OH . from 30% alkaline H 2 O 2 ; while only HO 2 . from more alkaline SPT. RIV for OH . was maximum at 1min irradiation of acidic 30%H 2 O 2 and 35%CP and minimum at 1min irradiation of neutral 30%H 2 O 2 . RIV for HO 2 . was maximum at 0min irradiation of alkaline 30%H 2 O 2 and minimum at 2min irradiation of SPT. The bleaching agents having pH- neutral and acidic were always associated with OH . ; weak alkaline with both OH . and HO 2 . ; and strong alkaline with HO 2 . only. It is recommended to check the pH of the bleaching agents and if found acidic, should be made alkaline to minimize oxidative damage to enamel itself and then to pulp/periodontal tissues. H 2 O 2 : hydrogen peroxide CP: carbamide peroxide SP: sodium perborate SPT: sodium perborate tetrahydrate ROS: reactive oxygen species 31 PNMR: 31 P nuclear magnetic resonance spectroscope RIV: relative integral value OH 2 . : hydroxyl radical HO 2 . : perhydroxyl radical O 2 . : super oxide radical DIPPMPO: 5-(Diisopropoxyphosphoryl)-5-methyl-1-pyrroline-N-oxide DEPMPO: 5-diethoxyphosphoryl-5-methyl-1-pyrroline-n-oxide DMPO: 5,5-dimethyl-1-pyrroline-N-oxide D 2 O: heavy water EDTA: ethylene diamine tetra acetic acid.
Murine T cell activation is regulated by surfen (bis-2-methyl-4-amino-quinolyl-6-carbamide)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warford, Jordan, E-mail: jordan.warford@dal.ca; Doucette, Carolyn D., E-mail: carolyn.doucette@dal.ca; Hoskin, David W., E-mail: d.w.hoskin@dal.ca
2014-01-10
Highlights: •Surfen is the first inhibitor of glycosaminoglycan function to be studied in murine T cells. •Surfen reduces T cell proliferation stimulated in vitro and in vivo. •Surfen reduces CD25 expression in T cells activated in vivo but not in vitro. •Surfen increases T cell proliferation when T cell receptor activation is bypassed. •Surfen’s effects are blocked by co-administration of heparin sulfate. -- Abstract: Surfen (bis-2-methyl-4-amino-quinolyl-6-carbamide) binds to glycosaminoglycans (GAGs) and has been shown to influence their function, and the function of proteoglycans (complexes of GAGs linked to a core protein). T cells synthesize, secrete and express GAGs and proteoglycansmore » which are involved in several aspects of T cell function. However, there are as yet no studies on the effect of GAG-binding agents such as surfen on T cell function. In this study, surfen was found to influence murine T cell activation. Doses between 2.5 and 20 μM produced a graduated reduction in the proliferation of T cells activated with anti-CD3/CD28 antibody-coated T cell expander beads. Surfen (20 mg/kg) was also administered to mice treated with anti-CD3 antibody to activate T cells in vivo. Lymphocytes from surfen-treated mice also showed reduced proliferation and lymph node cell counts were reduced. Surfen reduced labeling with a cell viability marker (7-ADD) but to a much lower extent than its effect on proliferation. Surfen also reduced CD25 (the α-subunit of the interleukin (IL)-2 receptor) expression with no effect on CD69 expression in T cells treated in vivo but not in vitro. When receptor activation was bypassed by treating T cells in vitro with phorbyl myristate acetate (10 ng/ml) and ionomycin (100 ng/ml), surfen treatment either increased proliferation (10 μM) or had no effect (2.5, 5 and 20 μM). In vitro treatment of T cells with surfen had no effect on IL-2 or interferon-γ synthesis and did not alter proliferation of the IL-2 dependent cell line CTLL-2. The effect of surfen was antagonized dose-dependently by co-treatment with heparin sulfate. We conclude that surfen inhibits T cell proliferation in vitro and in vivo. When T cell receptor-driven activation is bypassed surfen had a neutral or stimulatory effect on T cell proliferation. The results imply that endogenous GAGs and proteoglycans play a complex role in promoting or inhibiting different aspects of T cell activation.« less
Effect of bleaching on color change and surface topography of composite restorations.
Pruthi, Gunjan; Jain, Veena; Kandpal, H C; Mathur, Vijay Prakash; Shah, Naseem
2010-01-01
This study was conducted to determine the effect of 15% carbamide peroxide bleaching agent on color change and surface topography of different composite veneering materials (Filtek Z350 (3M ESPE), Esthet X (Dentsply India), and Admira (Voco, Germany). Methods. 30 samples were fabricated for evaluation of color change using CIELAB color system and Gonioreflectometer (GK 311/M, ZEISS). 45 disc-shaped specimens were made for evaluation of surface topography after bleaching (Nupro White Gold; Dentsply) using SEM. Statistical analysis. One way ANOVA and Multiple comparison tests were used to analyze the data. Statistical significance was declared if the P value was .05 or less. Results and conclusion. All the specimens showed significant discoloration (ΔE > 3.3) after their immersion in solutions representing food and beverages. The total color change after bleaching as compared to baseline color was significant in Filtek Z350 (P = .000) and Esthet X (P = .002), while it was insignificant for Admira (P = .18). Esthet X showed maximum surface roughness followed by Admira and Filtek Z350. Bleaching was effective in reducing the discoloration to a clinically acceptable value in all the three groups (ΔE < 3.3).
A review of the effect of vital teeth bleaching on the mechanical properties of tooth enamel.
Elfallah, Hunida M; Swain, Michael V
2013-09-01
Tooth whitening is considered the easiest and most cost-effective procedure for treating tooth discoloration. Contemporary bleaching agents contain hydrogen peroxide as the active ingredient. It is either applied directly or produced from its precursor, carbamide peroxide. A review of the published literature was undertaken to investigate the potential adverse effects of whitening products on dental enamel, with a focus on its mechanical properties and the influence of various parameters on study outcomes. There appear to be considerable differences in opinion as to whether changes in mechanical properties occur as a result of tooth whitening. However, the mechanical property findings of those studies appear to be related to the load applied during the indentation tests. Most studies which used loads higher than 500mN to determine enamel hardness showed no effect of bleaching, whereas those using lower loads were able to detect hardness reduction in the surface layer of enamel. In conclusion, bleaching reduces the hardness of the enamel surface of enamel, and that is more readily detected with instrumented low load testing systems. This hardness reduction may arise due to degradation or denaturation of enamel matrix proteins by the peroxide oxidation.
Zhang, Dandan; Wu, Mengting; Guo, Yuxing; Xun, Mingyue; Wang, Wenwen; Wu, Zhen; Pan, Daodong
2017-09-01
Surface-layer proteins (SLP) have been found in the outermost layer of the cell wall in many types of lactobacillus are considered to be an important factor with respect to intestinal immunity. The present study compared the effects of SLP extracted by different concentrations of LiCl and carbamide, and subsequently identified by sodium dodecyl sulfate-polyacrylamide gel electrophoresis, circular dichroism and differential scanning calorimetry. Furthermore, RAW 264.7 cells were used to evaluate the immunomodulatory effects of SLP. SLP were derived from Lactobacillus acidophilus CICC6074 with a molecular weight of 46 kDa, and consisted of 16.9% α-helix, 42.3% β-sheet, 20.8% β-turns and 22.5% random coils. SLP promoted NO secretion and higher quantities of NO were produced as the SLP concentrations increased. SLP concentrations over 50 µg mL -1 significantly decreased the amount of tumor necrosis factor-α secreted by RAW264.7 cells. SLP can trigger immunomodulatory effects in RAW 264.7 cells. This provides crucial information that will enable the further use of L. acidophilus in food, medicine and other products. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
NASA Astrophysics Data System (ADS)
Nam, S. H.; Hong, J. W.; Lee, H. J.; Jeon, Y. C.; Kim, G. C.
2017-08-01
The purpose of this study was to evaluate the influence of bleaching with nonthermal atmospheric pressure plasma and 15% hydrogen peroxide (HP) or 15% carbamide peroxide (CP). Sixty human enamel and dentin slabs were randomly assigned to six groups as follows: Group 1 was a control group and did not receive any treatment; Group 2 was exposed only to plasma, as a negative control; Group 3 was treated with 15% HP; Group 4 was treated with 15% HP plus plasma; Group 5 was treated with 15% CP alone; and Group 6 was treated with 15% CP plus plasma during 30 min bleaching treatments. A microhardness measurement was conducted according to a microhardness tester. The amount of calcium (Ca), phosphorus (P), chloride (Cl), sodium (Na), magnesium (Mg), and zinc (Zn) in the enamel and dentin was quantified with an electron probe microanalyzer (EPMA). The data were analyzed by using the Student’s t test and one-way analysis of variance (ANOVA), complemented by Tukey’s test. The statistical analysis did not show any significant differences in microhardness values and six mineral contents in all groups (p > 0.05). Therefore, we believe that the application of nonthermal atmospheric pressure plasma is a safe energy source for tooth bleaching.
Repeated-dose toxicity of common ragweed on rats
Kiss, Tivadar; Szabó, Andrea; Oszlánczi, Gábor; Lukács, Anita; Tímár, Zoltán; Tiszlavicz, László
2017-01-01
Ambrosia artemisiifolia L. is an invasive species with highly allergenic pollens. Ragweed originates from North America, but it also occurs and is spreading in Europe, causing seasonal allergic rhinitis for millions of people. Recently, the herb of A. artemisiifolia has gained popularity as medicinal plant and food. The effects of its long-term intake are unknown; there are no toxicological data to support the safe use of this plant. The aim of our study was to assess the repeated dose toxicity of A. artemisiifolia on animals. Ragweed puree was administered in low dose (500 mg/kg b. w.) and high dose (1000 mg/kg b. w.) to male Wistar rats according to 407 OECD Guidelines for the Testing of Chemicals. Clinical symptoms, various blood chemical parameters, body weight and organ weights of the rats were measured. Reduced liver function enzymes (AST, ALT), reduced triglyceride level in the low dose and increased carbamide level in the high dose group were observed. The weight of the liver relative to body weight was significantly reduced in both groups, while the brain weight relative to body weight was significantly elevated in both groups. According to our results, the repeated use of ragweed resulted in toxic effects in rats and these results question the safety of long-term human consumption of common ragweed. PMID:28472131
Justification of the Production Process of Pressed Wood and Study of its Properties
NASA Astrophysics Data System (ADS)
Polilov, A. N.; Dornyak, O. R.; Shamaev, V. A.; Rumachik, M. M.
2018-05-01
Results of a numerical analysis of the stress-strain state of wood during its pressing in different symmetry directions of the anisotropic material are presented. It is shown that the anisotropy of mechanical properties of wood is an important factor determining both the structural characteristics of the porous system and its strength. A mathematical modeling of the process of pressing wood as a three-phase anisotropic rheologically complex capillary-porous system allows one to predict parameters of the resulting wood composite. The compressed wood obtained by the production modes developed has a tensile strength eight times greater than that of the natural one, which is comparable to the strength of the St3 steel, but its specific strength is higher than that of the St45 steel. Compression and impregnation of softwood species with an aqueous solution of carbamide allows one to harden them. This kind of treatment endows the wood with enhanced strength characteristics comparable to the characteristics of the St3 steel. The special features of tensile tests used to estimate the elastic modulus and strength characteristics of such materials are considered. Data obtained by different testing methods are correlated, and characteristics of the strengthened wood and some brends of steel are compared.
Pinheiro, Helena Burlamaqui; Cardoso, Paulo Eduardo Capel
2011-06-01
To investigate the influence of calcium phosphate enhanced home whitening agents on human enamel and dentin surface microhardness and ultramorphology. Five intact molars crowns were used for ultrastructural analysis and five for microhardness test. Each resulting coronal structure was cut in slices. After measuring baseline Knoop Hardness Number (KHN) of the enamel and dentin, the slices were divided into six experimental groups and one control (n= 5). G1= 15% carbamide peroxide (CP); G2= 16% CP; G3= Ca and PO4 (remineralizing agent); G4= 16% CP with Ca and PO4; G5= 7.5% hydrogen peroxide (HP) with Ca and PO4; G6=7.5% HP with Ca. After each daily session of treatment, specimens were stored in distilled water (37 degrees C) until the next session. Products were applied for 2 weeks, according to manufacturers' instructions. Additional KHN weredetermined. Conventional whitening agents (G1; G2) and the gel with Ca (G6), caused KHN decrease (P< 0.05).The remineralizing and whitening agents with Ca and PO4 (G3; G4; G5) did not change KHN. A change of morphology was observed on enamel and dentin surfaces in G1; G2; G5.
Effect of tooth-bleaching on the carbonate concentration in dental enamel by Raman spectroscopy.
Vargas-Koudriavtsev, Tatiana; Herrera-Sancho, Óscar-Andrey
2017-01-01
There are not many studies evaluating the effects of surface treatments at the molecular level. The aim of this in vitro study was to analyze the concentration of carbonate molecules in dental enamel by Raman spectroscopy after the application of in-office and home whitening agents. Sixty human teeth were randomly divided into six groups and exposed to three different home bleaching gels (Day White) and three in-office whitening agents (Zoom! Whitespeed and PolaOffice) according to the manufacturer´s instructions. The concentration of carbonate molecules in enamel was measured prior to and during the treatment by means of Raman spectroscopy. Statistical analysis included repeated measures analysis of variance ( p ≤0.05) and Bonferroni pairwise comparisons. At home bleaching agents depicted a decrease in the carbonate molecule. This decrease was statistically significant for the bleaching gel with the highest hydrogen peroxide concentration ( p ≤0,05). In-office whitening agents caused an increase in carbonate, which was significant for all three groups ( p ≤0,05). In-office bleaching gels seem to cause a gain in carbonate of the enamel structure, whilst at-home whitening gels caused a loss in carbonate. Key words: Bleaching, whitening, hydrogen peroxide, carbamide peroxide, Raman spectroscopy, carbonate.
Effect of tooth-bleaching on the carbonate concentration in dental enamel by Raman spectroscopy
Vargas-Koudriavtsev, Tatiana; Herrera-Sancho, Óscar-Andrey
2017-01-01
Background There are not many studies evaluating the effects of surface treatments at the molecular level. The aim of this in vitro study was to analyze the concentration of carbonate molecules in dental enamel by Raman spectroscopy after the application of in-office and home whitening agents. Material and Methods Sixty human teeth were randomly divided into six groups and exposed to three different home bleaching gels (Day White) and three in-office whitening agents (Zoom! Whitespeed and PolaOffice) according to the manufacturer´s instructions. The concentration of carbonate molecules in enamel was measured prior to and during the treatment by means of Raman spectroscopy. Statistical analysis included repeated measures analysis of variance (p≤0.05) and Bonferroni pairwise comparisons. Results At home bleaching agents depicted a decrease in the carbonate molecule. This decrease was statistically significant for the bleaching gel with the highest hydrogen peroxide concentration (p≤0,05). In-office whitening agents caused an increase in carbonate, which was significant for all three groups (p≤0,05). Conclusions In-office bleaching gels seem to cause a gain in carbonate of the enamel structure, whilst at-home whitening gels caused a loss in carbonate. Key words:Bleaching, whitening, hydrogen peroxide, carbamide peroxide, Raman spectroscopy, carbonate. PMID:28149472
Does at-home bleaching induce systemic oxidative stress in healthy subjects?
Akbari, M; Nejat, A H; Farkhondeh, N; Mehraban Moghadam, S; Hashemy, S I; Mohammadipour, H S
2017-03-01
At-home bleaching is a technique characterized by the use of carbamide peroxide or hydrogen peroxide as a tooth-whitening agent. However, no data exist regarding systemic safety of this technique. The aim of this study was to investigate the effect of at-home bleaching on serum redox homeostasis. Twenty-nine healthy volunteers who requested tooth-whitening participated in this study. Specified bleaching trays were fabricated for the maxilla and mandible arches. Each participant was given two syringes containing 9% hydrogen peroxide gel to use for 30 min/night for 14 nights consecutively. To evaluate the redox status, the serum concentrations of malondialdehyde (MDA), total antioxidant capacity (TAC) and pro-oxidant-antioxidant balance (PAB) were measured. Blood samples were obtained in the morning prior to initiation of study and the morning after expiration of the bleaching period. The collected data were analyzed using Student's t-test with 95% confidence interval. Twenty-three subjects completed the study. MDA, PAB and TAC were significantly increased after the bleaching period (P = 0.001, 0.001 and 0.002, respectively). At-home bleaching revealed the potential to disturb oxidant-antioxidant balance and induce oxidative stress. Its clinical relevance is unfavourable and potential side-effects of at-home bleaching should be considered. © 2016 Australian Dental Association.
Effect of tooth bleaching agents on protein content and mechanical properties of dental enamel.
Elfallah, Hunida M; Bertassoni, Luiz E; Charadram, Nattida; Rathsam, Catherine; Swain, Michael V
2015-07-01
This study investigated the effect of two bleaching agents, 16% carbamide peroxide (CP) and 35% hydrogen peroxide (HP), on the mechanical properties and protein content of human enamel from freshly extracted teeth. The protein components of control and treated enamel were extracted and examined on sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). Marked reduction of the protein matrix and random fragmentation of the enamel proteins after bleaching treatments was found. The mechanical properties were analyzed with Vickers indentations to characterize fracture toughness, and nanoindentation to establish enamel hardness, elastic modulus and creep deformation. Results indicate that the hardness and elastic modulus of enamel were significantly reduced after treatment with CP and HP. After bleaching, the creep deformation at maximum load increased and the recovery upon unloading reduced. Crack lengths of CP and HP treated enamel were increased, while fracture toughness decreased. Additionally, the microstructures of fractured and indented samples were examined with field emission gun scanning electron microscopy (FEG-SEM) showing distinct differences in the fracture surface morphology between pre- and post-bleached enamel. In conclusion, tooth bleaching agents can produce detrimental effects on the mechanical properties of enamel, possibly as a consequence of damaging or denaturing of its protein components. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
de Souza, Fernanda Lopes; Oliveira, Mariana; Nunes, Marianne Brochado; Serafim, Lucas Horstmann; Azambuja, Alan Arrieira; Braga, Luisa Maria G. de M.; Saur, Lisiani; de Souza, Maria Antonieta Lopes; Xavier, Léder Leal
2014-01-01
Oral squamous cell carcinoma (OSCC) is a public health problem. The hamster buccal pouch model is ideal for analyzing the development of OSCC. This research analysed the effects of sunitinib (tyrosine kinase inhibitor) in precancerous lesions induced by 7,12-dimethylbenz(a)anthracene (DMBA) in this model. Thirty-four male hamsters, divided into six groups: control—C (n = 7), acetone—A (n = 12), carbamide peroxide—CP (n = 5 ), acetone and CP—A+CP (n = 8), 1% DMBA in acetone and CP—DA+CP (n = 6), and 1% DMBA in acetone and CP and 4-week treatment with sunitinib—DA+CP+S (n = 7). The aspects evaluated were anatomopathological features (peribuccal area, paws, nose, and fur), histological sections of the hamster buccal pouches (qualitatively analyzed), epithelium thickness, and the rete ridge density (estimated). Sunitinib was unable to attenuate the decrease in weight gain induced by DMBA; no increase in volume was detected in the pouch and/or ulceration, observed in 43% of the animals in the DA+CP group. DA+CP groups presented a significant increase in rete ridge density compared to the control groups (P < 0.01) which was reverted by sunitinib in the DA+CP+S group. Sunitinib seems to have important benefits in early stage carcinogenesis and may be useful in chemoprevention. PMID:24693453
Rattacaso, Raphael Mendes Bezerra; da Fonseca Roberti Garcia, Lucas; Aguilar, Fabiano Gamero; Consani, Simonides; de Carvalho Panzeri Pires-de-Souza, Fernanda
2011-04-01
The purpose of this study was to evaluate the bleaching agent action on color stability, surface roughness and microhardness of composites (Charisma, Filtek Supreme and Heliomolar - A2) submitted to accelerated artificial aging (AAA). A Teflon matrix (12 x 2 mm) was used to fabricate 18 specimens (n=6) which, after polishing (Sof-Lex), were submitted to initial color reading (ΔE), Knoop microhardness (KHN) (50 g/15 s load) and roughness (R(a)) (cut-off 0.25 mm) tests. Afterwards, the samples were submitted to AAA for 384 hours and new color, microhardness and roughness readings were performed. After this, the samples were submitted to daily application (4 weeks) of 16% Carbamide Peroxide (NiteWhite ACP) for 8 hours and kept in artificial saliva for 16 hours. New color, microhardness and roughness readings were made at the end of the cycle, and 15 days after bleaching. Comparison of the ΔE means (2-way ANOVA, Bonferroni, P<.05) indicated clinically unacceptable color alteration for all composites after AAA, but without significant difference. Statistically significant increase in the KHN values after AAA was observed, but without significant alterations 15 days after bleaching. For R(a) there was no statistically significant difference after AAA and 15 days after bleaching. The alterations promoted by the bleaching agent and AAA are material dependent.
Gurgan, Sevil; Yalcin Cakir, Filiz
2008-09-01
This in vitro study evaluated the effects of three mouthrinses (Listerine--alcohol containing, Oral B--alcohol free and Rembrandt Plus--peroxide whitening rinse) on the surface hardness, gloss and colour of a nanofill (Filtek Supreme) and nanohybrid (Simile) composite resin that had been subjected to bleaching treatment. 30 specimens of each material were fabricated and randomly divided into three groups of 10. The hardness, gloss and CIE Lab colour parameters of each specimen were assessed prior to the experiments. Specimens were exposed to the 10% carbamide peroxide bleaching agent (Vivastyle) for 2 hours per day for 14 days. Following the bleaching treatment measurements were repeated. The specimens were then conditioned with mouthrinses for 12 hours which was equivalent in time to 1 year of two minutes daily use. The specimens were measured again for hardness, gloss and colour and data were subjected to the statistical analysis. The result of this study showed no statististical difference between the restorative materials after bleaching and the use of mouthrinses (p > 0.05). Bleaching treatment and the use of mouthrinses af fected the hardness, gloss and colour of both resins. Significant differences were observed with the use of mouthrinses for all parameters (p < 0.05). Rembrandt Plus promoted the greatest changes, followed by Listerine and Oral B.
Titanium dioxide in dental enamel as a trace element and its variation with bleaching
Durán-Sedó, Randall; Herrera-Sancho, Óscar-Andrey
2018-01-01
Background Titanium is a less studied trace element in dental enamel. Literature relates an increased Titanium concentration with a decreased enamel crystal domain size, which in turn is related to a higher color value. The aim of our study was to analyze the effect of tooth bleaching agents on its concentration in dental enamel by means of confocal Raman spectroscopy. Material and Methods Human teeth were randomly distributed in six experimental groups (n=10) and submitted to different bleaching protocols according to the manufacturer´s instructions. Confocal Raman spectroscopy was carried out in order to identify and quantify the presence of titanium dioxide molecules in enamel prior to and during whitening. Statistical analysis included repeated measures analysis of variance (p≤0.05) and Bonferroni pairwise comparisons. Results Titanium dioxide concentration was negatively affected by the longer bleaching protocols (at-home bleaching gels). All in-office whitening products increased significantly the studied molecule (p≤0,05). Conclusions All dental specimens depicted the presence of titanium dioxide as a trace element in dental enamel. Bleaching gels that have to be applied at higher concentrations but for shorter periods of time increase the concentration of titanium dioxide, whilst at-home whitening gels used for longer periods of time despite the lower concentration caused a loss in titanium. Key words:Bleaching, whitening, hydrogen peroxide, carbamide peroxide, Raman spectroscopy, titanium dioxide. PMID:29930771
Titanium dioxide in dental enamel as a trace element and its variation with bleaching.
Vargas-Koudriavtsev, Tatiana; Durán-Sedó, Randall; Herrera-Sancho, Óscar-Andrey
2018-06-01
Titanium is a less studied trace element in dental enamel. Literature relates an increased Titanium concentration with a decreased enamel crystal domain size, which in turn is related to a higher color value. The aim of our study was to analyze the effect of tooth bleaching agents on its concentration in dental enamel by means of confocal Raman spectroscopy. Human teeth were randomly distributed in six experimental groups (n=10) and submitted to different bleaching protocols according to the manufacturer´s instructions. Confocal Raman spectroscopy was carried out in order to identify and quantify the presence of titanium dioxide molecules in enamel prior to and during whitening. Statistical analysis included repeated measures analysis of variance ( p ≤0.05) and Bonferroni pairwise comparisons. Titanium dioxide concentration was negatively affected by the longer bleaching protocols (at-home bleaching gels). All in-office whitening products increased significantly the studied molecule ( p ≤0,05). All dental specimens depicted the presence of titanium dioxide as a trace element in dental enamel. Bleaching gels that have to be applied at higher concentrations but for shorter periods of time increase the concentration of titanium dioxide, whilst at-home whitening gels used for longer periods of time despite the lower concentration caused a loss in titanium. Key words: Bleaching, whitening, hydrogen peroxide, carbamide peroxide, Raman spectroscopy, titanium dioxide.
Teixeira, Erica C N; Ritter, André V; Thompson, Jeffrey Y; Leonard, Ralph H; Swift, Edward J
2004-12-01
To evaluate the effect of tray-based and trayless tooth whitening systems on surface and subsurface microhardness of human enamel. Enamel slabs were obtained from recently extracted human third molars. Specimens were randomly assigned to six groups according to tooth whitening treatment (n = 10): 6.0% hydrogen peroxide (HP) (Crest Whitestrips), 6.5% HP (Crest Professional Whitestrips), 7.5% HP (Day White Excel 3), 9.5% HP (Day White Excel 3), 10% carbamide peroxide (Opalescence), and a control group (untreated). Specimens were treated for 14 days following manufacturers' recommended protocols, and were immersed in artificial saliva between treatments. Enamel surface Knoop microhardness (KHN) was measured immediately before treatment, and at days 1, 7, and 14 of treatment. After treatment, subsurface microhardness was measured at depths of 50-500 microm. Data were analyzed for statistical significance using analysis of variance. Differences in microhardness for treated vs. untreated enamel surface were not statistically significant at any time interval. For 6.5% and 9.5% HP, there was a decrease in surface microhardness values during treatment, but at the end of treatment the microhardness values were not statistically different from the baseline values. For the enamel subsurface values, no differences were observed between treated vs. untreated specimens at each depth. Trayless and tray-based tooth whitening treatments do not significantly affect surface or subsurface enamel microhardness.
In vitro Comparison of Impact of Different Bleaching Agents on the Microhardness of Enamel.
Dey, Subhra; Pandey, Vinisha; Kumar, Anuj; Awasthi, Neha; Sahu, Anshu; Pujari, Sudarshan C
2016-03-01
Various agents are used these days for increasing the esthetics. One such procedure is bleaching that offers various advantages, as it is minimal invasive and cheap option to color the teeth and remove stain. The altered enamel after the bleaching process shows surface demineralization and porosities. The present study aimed to evaluate the effect of different bleaching agents on the microhardness of enamel. A total of 100 freshly human extracted maxillary premolar teeth were selected for the study. Teeth with sound tooth structure were included for the study. All the specimens were randomly divided into four groups with 25 specimens in each group depending upon the type of bleaching agent used: Group A, artificial saliva (Control group); Group B, 35% hydrogen peroxide (HP); Group C, 25% HP; Group D, 10% carbamide peroxide (CP). Knoop Hardness Number (KHN) was calculated at 24, 48-hour, and 7-week interval. Results showed no statistical significant differences between the microhardness of enamel of different groups (p < 0.005). A slight fall in the value of KHN was seen in all the groups, except for the control group, although the results were statistically nonsignificant (p > 0.005). Although nonsignificantly, all the bleaching solutions produced some amount of alterations in the microstructure of enamel. More studies with higher study groups and more advanced estimation technologies are required to minimize microstructure alterations and promote for better outcome of bleaching procedures.
Effect of bleaching on color stability and roughness of composite resins aged in staining beverage.
Rodrigues, Camila Silva; Mozzaquatro, Lisandra Rossato; Dala Nora, Bárbara; Jacques, Letícia Borges; Mallmann, André
2017-01-01
Composite resin properties can be affected by contact with gel during bleaching procedures; however, there is no consensus about the effect of this contact on resin susceptibility to color change. This study aimed to evaluate staining susceptibility and surface roughness changes in 2 composite resins (Filtek Z250 XT and Filtek Z350 XT) after application of bleaching peroxides and storage in different media. Forty-two disc-shaped specimens of each composite were made, polished, and divided into 3 groups according to treatment type (35% hydrogen peroxide, 16% carbamide peroxide, or deionized water as a control group). These groups were subdivided into 2 groups according to immersion media (n = 7): deionized water or red wine. Color and average roughness (Ra) measurements were taken 24 hours after specimen preparation (T0), immediately after bleaching procedures (T1), and immediately after aging (staining; T2). Statistical analyses were performed using 2-way analyses of variance for repeated measurements and the Tukey test (P < 0.05). Bleaching resulted in minimal color change (ΔE* < 1) in all groups. Filtek Z350 XT specimens presented greater mean values of color change. The Ra values did not increase significantly after bleaching procedures or aging (staining) in all groups. Thus, bleaching agents did not significantly change the color or roughness of the composite resins used in this study.
Conde, Artur; Diallinas, George; Chaumont, François; Chaves, Manuela; Gerós, Hernâni
2010-06-01
The recent breakthrough discoveries of transport systems assigned with atypical functions provide evidence for complexity in membrane transport biochemistry. Some channels are far from being simple pores creating hydrophilic passages for solutes and can, unexpectedly, act as enzymes, or mediate high-affinity uptake, and some transporters are surprisingly able to function as sensors, channels or even enzymes. Furthermore, numerous transport studies have demonstrated complex multiphasic uptake kinetics for organic and mineral nutrients. The biphasic kinetics of glucose uptake in Saccharomyces cerevisiae, a result of several genetically distinct uptake systems operating simultaneously, is a classical example that is a subject of continuous debate. In contrast, some transporters display biphasic kinetics, being bona fidae dual-affinity transporters, their kinetic properties often modulated by post-translational regulation. Also, aquaporins have recently been reported to exhibit diverse transport properties and can behave as highly adapted, multifunctional channels, transporting solutes such as CO(2), hydrogen peroxide, urea, ammonia, glycerol, polyols, carbamides, purines and pyrimidines, metalloids, glycine, and lactic acid, rather than being simple water pores. The present review provides an overview on some atypical functions displayed by transporter proteins and discusses how this novel knowledge on cellular uptake systems may be related to complex multiphasic uptake kinetics often seen in a wide variety of living organisms and the intriguing diffusive uptake of sugars and other solutes. Copyright 2009 Elsevier Ltd. All rights reserved.
Effect of Home Bleaching on the Translucency of CAD/CAM Systems.
Karci, Muhammet; Demir, Necla
2017-11-10
To evaluate the effect of a home bleaching agent (Opalescence PF) on the translucency of CAD/CAM ceramic systems. The 28 sintered ceramic specimens (IPS Empress CAD and IPS e.max CAD; 15 mm long, 10 mm wide, 1 mm thick) were divided into two subgroups as control and bleaching groups (n = 7). Carbamide peroxide (CP), 16%, home bleaching agent was applied onto the surface of each specimen for 6 hours per day for 7 days. A spectrophotometer (VITA Easyshade Advance) was used to measure the CIE L * a * b * coordinates and the reflectance value (Y) of the specimens on white and black backgrounds. The translucency parameter (TP), contrast ratio (CR), and opalescence parameter (OP) of the specimens were calculated. The data were statistically analyzed using Kolmogorov-Smirnov, one-way ANOVA, Tukey's test, and Pearson's correlation. Statistically significant differences in the TP values after 16% CP bleaching treatment were observed (p ˂ 0.05); however, no significant differences were found in the OP and CR values after the surface treatment (p ˃ 0.05). According to our study, patients who have all-ceramic restorations in their mouths should be careful when using home bleaching agents, because whitening agents can affect the translucency of all-ceramic restorations such as e.max CAD and Empress CAD. © 2017 by the American College of Prosthodontists.
Clinical evaluation of a new 10% carbamide peroxide tooth-whitening agent.
Barnes, D M; Kihn, P W; Romberg, E; George, D; DePaola, L; Medina, E
1998-10-01
NUPRO Gold Tooth Whitening System was evaluated for efficacy according to the proposed ADA guidelines for acceptance. Sixty participants with discolored anterior teeth participated in a 14-day, double-blind, clinical trial. The participants were matched for age, gender, and oral health status and were given either a placebo gel without the active agent or the NUPRO Gold active gel, which they wore in a custom-fabricated mouth guard for home use. The shade of each participant's maxillary anterior teeth was evaluated using a value-oriented Vita Lumin Vacuum Shade Guide before the study. The same shade guide was used to determine shade changes. Time of use of the agent and potential side effects, such as tooth and gingival hypersensitivity and tissue irritation, were assessed at all recall examinations and were recorded by participants in daily diaries. The average shade change for the placebo users was less than one shade. The average shade change for the NUPRO Gold users was 6.96 shades. Tooth hypersensitivity varied from none to severe. Tissue irritation was minimal. The results of these evaluations indicate that NUPRO Gold is effective as a tooth-whitening system, when administered properly under the supervision of a dentist, with commonly reported side effects of transient tooth sensitivity and minimal gingival sensitivity. Little or no change in tissue health was noted. This study was supported by Dentsply Preventive Care (York, Pennsylvania).
Jiang, Jian-Guo; Zhao, Zhen-Zhen; Du, Xue-Juan; Sui, Ji-Chao; Wu, Shi-Yao
2007-04-01
The straw contains a high content of lignin, which cannot be well utilized by anaerobic bacteria in high solid anaerobic digestion process. This paper presents the experimental investigation of the straw pre-treatment, which aims to destroy the complex structure of the lignin to enhance its high solid anaerobic digestion. The straw is pre-treated in different solutions including NaOH, ammonia, H2SO4, and carbamide. The pre-treating effects are expressed by COD concentration dissolved in the solutions and the 14-day biogas generation in the enhanced aerogenic experiment. Different affecting factors, such as the concentration of the chemical solution, the species of the straw, the pre-treatment reaction time, the reaction temperature and the size of the straw, are investigated. The results show that NaOH solution is the most effective pre-treatment chemical among the four different solutions. The experimental results still indicate that the accumulative biogas production can be 1 500 mL (10 g straw) in 14 days after pre-treatment in 4 mg/L NaOH solution and the dissolved COD in the solution reaches 39 000 mg/L after 24 hours. In addition, the experiment shows that the lignin content in the straw is reduced from 28% to 19% after pre-treatment in 1.5% (in weight) NaOH solution, and it can improve the straw treatment efficiency using high solid anaerobic digestion process.
Chen, He; Niu, Jinfeng; Qin, Tao; Ma, Qi; Wang, Lei; Shu, Guowei
2015-01-01
Lactobacillus acidophilus not only improves the intestinal flora balance but also inhabits the growth of undesirable microorganisms in intestine, which is benefit to the health of humans and animals. Plackett-Burman and steepest ascent experiment are the rapid and concise ways of screening the main effective factors. This study is aimed to select the main influence factors and optimize the medium for Lactobacillus acidophilus by Plackett-Burman experiment and steepest ascent experiment. The ideal carbon source was screened among glucose, maltose, lactose and whey powder, and the ideal nitrogen source was screened among casein hydrolysate, peptone, yeast extract powder, fish meal, carbamide, ammonium sulfate and sodium nitrate by single factor experiment. Plackett-Burman and steepest ascent experiment were applied to screen the main effective factors of Lactobacillus acidophilus among peptone, beef extract, yeast extract powder, glucose, K2HPO4, C6H14O7N2, CH3COONa, MgSO4 and Tween-80. Result. The results indicated that glucose (p = 0.01510) as negative factor and K2HPO4 (p = 0.02017) as positive effect were the significant growth factors of Lactobacillus acidophilus, CH3COONa (p = 0.09273) as positive effect was an important factor, and the optimized medium was as follows: glucose - 21 g/L, K2HPO4 - 3.5 g/L, CH3COONa - 6.5 g/L, peptone - 10 g/L, beef extract - 8 g/L, yeast extract pow. nd. Lactobacillus acidophilus not only improves the intestinal flora balance but also inhabits the growth of undesirable microorganisms in intestine, which is benefit to the health of humans and animals. Plackett-Burman and steepest ascent experiment are the rapid and concise ways of screening the main effective factors. This study is aimed to select the main influence factors and optimize the medium for Lactobacillus acidophilus by Plackett-Burman experiment and steepest ascent experiment. Material and methods. The ideal carbon source was screened among glucose, maltose, lactose and whey powder, and the ideal nitrogen source was screened among casein hydrolysate, peptone, yeast extract powder, fish meal, carbamide, ammonium sulfate and sodium nitrate by single factor experiment. Plackett-Burman and steepest ascent experiment were applied to screen the main effective factors of Lactobacillus acidophilus among peptone, beef extract, yeast extract powder, glucose, K2HPO4, C6H14O7N2, CH3COONa, MgSO4 and Tween-80. Result. The results indicated that glucose (p = 0.01510) as negative factor and K2HPO4 (p = 0.02017) as positive effect were the significant growth factors of Lactobacillus acidophilus, CH3COONa (p = 0.09273) as positive effect was an important factor, and the optimized medium was as follows: glucose - 21 g/L, K2HPO4 - 3.5 g/L, CH3COONa - 6.5 g/L, peptone - 10 g/L, beef extract - 8 g/L, yeast extract powder - 8 g/L, C6H14O7N2 - 2 g/L, MgSO4 - 0.2 g/L and Tween-80 - 1 mL/L when the maximum viable count could achieve 2.72·109 cfu/mL. The experimental model is reliable and the experimental results are of good stability. Variance analysis is performed to determine the adequacy and significance of the linear model. Thus, Plackett-Burman and steepest ascent experiment improve the veracity of optimization the medium for Lactobacillus acidophilus compared with the previous research.
Dantas, Andréa Abi Rached; Bortolatto, Janaina Freitas; Roncolato, Ávery; Merchan, Hugo; Floros, Michael Christopher; Kuga, Milton Carlos; Oliveira Junior, Osmir Batista de
2015-01-01
The purpose of this in vitro study was to compare the efficacy of a bleaching toothpaste containing Blue Covarine vs. conventional tooth bleaching techniques using peroxides (both in-office and at-home). Samples were randomly distributed into five experimental groups (n=15): C - Control; BC - Bleaching toothpaste containing Blue Covarine; WBC - Bleaching toothpaste without Blue Covarine; HP35 - In-office bleaching using 35% hydrogen peroxide; and CP10 - At-home bleaching with 10% carbamide peroxide. The dental bleaching efficacy was determined by the color difference (ΔE), luminosity (ΔL), green-red axis (Δa), and blue-yellow axis (Δb). The CIELab coordinates were recorded with reflectance spectroscopy at different times: T0 - baseline, T1 - immediately after bleaching, T2 - 7 days, T3 - 14 days, and T4 - 21 days after the end of treatments. Data were analyzed by a repeated measures mixed ANOVA and post hoc Bonferroni test, with a significance level of 5%. No significant differences were found between the treatment groups C, BC, and WBC. The groups HP35 and CP10 showed significantly higher whitening efficacy than groups C, BC, and WBC. There were no significant differences in the whitening efficacy between a Blue Covarine containing toothpaste, a standard whitening toothpaste, and a control. Neither of the whitening toothpastes tested were as effective as in-office or at-home bleaching treatments.
DANTAS, Andréa Abi Rached; BORTOLATTO, Janaina Freitas; RONCOLATO, Ávery; MERCHAN, Hugo; FLOROS, Michael Christopher; KUGA, Milton Carlos; de OLIVEIRA, Osmir Batista
2015-01-01
ABSTRACT Objective The purpose of this in vitro study was to compare the efficacy of a bleaching toothpaste containing Blue Covarine vs. conventional tooth bleaching techniques using peroxides (both in-office and at-home). Material and Methods Samples were randomly distributed into five experimental groups (n=15): C - Control; BC – Bleaching toothpaste containing Blue Covarine; WBC – Bleaching toothpaste without Blue Covarine; HP35 - In-office bleaching using 35% hydrogen peroxide; and CP10 – At-home bleaching with 10% carbamide peroxide. The dental bleaching efficacy was determined by the color difference (ΔE), luminosity (ΔL), green-red axis (Δa), and blue-yellow axis (Δb). The CIELab coordinates were recorded with reflectance spectroscopy at different times: T0 - baseline, T1 – immediately after bleaching, T2 - 7 days, T3 - 14 days, and T4 - 21 days after the end of treatments. Data were analyzed by a repeated measures mixed ANOVA and post hoc Bonferroni test, with a significance level of 5%. Results No significant differences were found between the treatment groups C, BC, and WBC. The groups HP35 and CP10 showed significantly higher whitening efficacy than groups C, BC, and WBC. Conclusions There were no significant differences in the whitening efficacy between a Blue Covarine containing toothpaste, a standard whitening toothpaste, and a control. Neither of the whitening toothpastes tested were as effective as in-office or at-home bleaching treatments. PMID:26814462
Influence of Enamel Thickness on Bleaching Efficacy: An In-Depth Color Analysis
Públio, Juliana do Carmo; D’Arce, Maria Beatriz Freitas; Catelan, Anderson; Ambrosano, Gláucia Maria Bovi; Aguiar, Flávio Henrique Baggio; Lovadino, José Roberto; Lima, Débora Alves Nunes Leite
2016-01-01
This study evaluated the influence of different enamel thicknesses and bleaching agents on treatment efficacy in-depth by spectrophotometry color analysis. Eighty bovine dental fragments were previously stained in black tea solution and randomly assigned into eight groups (n=10), 1.75mm dentin thickness and different enamel thicknesses as follows: 0.5mm, 1.0mm planned, 1.0mm unplanned (aprismatic enamel), and absence of enamel. The 10% carbamide peroxide (CP) and 35% hydrogen peroxide (HP) bleaching gels were applied on the enamel surface following the manufacturer's recommendations. Color of underlying dentin was evaluated at four times: after staining with tea (baseline) and after each one of the three weeks of bleaching treatment, by CIE L*a*b* system using reflectance spectrophotometer (CM 700d, Konica Minolta). The ΔE, ΔL, Δa, and Δb values were recorded and subjected to repeated measures ANOVA and Tukey’s test (α=0.05). The results showed an increase on lightness (L*), with decreased redness (a*) and yellowness (b*). At first and second week, bleaching with CP showed higher whitening effectiveness compared to bleaching with HP and the presence of aprismatic enamel significantly reduced ΔE for bleaching with CP. After three weeks of bleaching, few differences were observed between CP and HP groups, and outer enamel layer caused no influence on bleaching effectiveness. Overall, both at-home and in-office bleaching treatments were effective and the presence of aprismatic enamel did not interfere on the whitening efficacy. PMID:27708725
Influence of Enamel Thickness on Bleaching Efficacy: An In-Depth Color Analysis.
Públio, Juliana do Carmo; D'Arce, Maria Beatriz Freitas; Catelan, Anderson; Ambrosano, Gláucia Maria Bovi; Aguiar, Flávio Henrique Baggio; Lovadino, José Roberto; Lima, Débora Alves Nunes Leite
2016-01-01
This study evaluated the influence of different enamel thicknesses and bleaching agents on treatment efficacy in-depth by spectrophotometry color analysis. Eighty bovine dental fragments were previously stained in black tea solution and randomly assigned into eight groups (n=10), 1.75mm dentin thickness and different enamel thicknesses as follows: 0.5mm, 1.0mm planned, 1.0mm unplanned (aprismatic enamel), and absence of enamel. The 10% carbamide peroxide (CP) and 35% hydrogen peroxide (HP) bleaching gels were applied on the enamel surface following the manufacturer's recommendations. Color of underlying dentin was evaluated at four times: after staining with tea (baseline) and after each one of the three weeks of bleaching treatment, by CIE L*a*b* system using reflectance spectrophotometer (CM 700d, Konica Minolta). The ΔE, ΔL, Δa, and Δb values were recorded and subjected to repeated measures ANOVA and Tukey's test (α=0.05). The results showed an increase on lightness (L*), with decreased redness (a*) and yellowness (b*). At first and second week, bleaching with CP showed higher whitening effectiveness compared to bleaching with HP and the presence of aprismatic enamel significantly reduced ΔE for bleaching with CP. After three weeks of bleaching, few differences were observed between CP and HP groups, and outer enamel layer caused no influence on bleaching effectiveness. Overall, both at-home and in-office bleaching treatments were effective and the presence of aprismatic enamel did not interfere on the whitening efficacy.
Attia, Mariana Lerner; Cavalli, Vanessa; do Espírito Santo, Ana Maria; Martin, Airton Abrahão; D'Arce, Maria Beatriz Freitas; Aguiar, Flávio Henrique Baggio; Lovadino, José Roberto; do Rego, Marcos Augusto; Cavalcanti, Andréa Nóbrega; Liporoni, Priscila Christiane Suzy
2015-07-01
The purpose of this study was to evaluate surface roughness and changes in the composition of enamel submitted to different bleaching protocols and toothbrushing with regular and whitening toothpastes. Bleaching treatment could promote morphological and chemical changes in enamel surface. Enamel blocks were randomized into nine groups (n=10) according to the bleaching treatment (no bleaching, control group; 6% hydrogen peroxide, HP; or 10% carbamide peroxide, CP) and toothpaste used (placebo, PL; regular, R; or whitening dentifrice, W). Bleaching was performed according to manufacturers' instructions and all groups were submitted to 30,000 cycles of simulated toothbrushing with toothpaste (PL, R, or W). Mineral content evaluation and enamel roughness were evaluated initially (T1), after bleaching (T2), and after toothbrushing (T3), using an energy-dispersive micro X-ray fluorescence spectrometer and profilometry, respectively. Data were statistically analyzed with two way ANOVA, Tukey, and Dunnett tests (5%). Enamel surface roughness was influenced by bleaching and toothbrushing. Surface roughness increased for the groups that brushed with the placebo dentifrice (CP+PL, HP+PL, C+PL) and for the control group that brushed with whitening dentifrice (C+W). Enamel Ca/P ratio decreased after bleaching, but toothbrushing, regardless of the dentifrice used, did not reduce the enamel mineral content. The bleaching treatment resulted in a decrease of enamel mineral content, but the studied dentifrices did not contribute to surface mineral loss.
Influence of bleaching agents on surface roughness of sound or eroded dental enamel specimens.
Azrak, Birgül; Callaway, Angelika; Kurth, Petra; Willershausen, Brita
2010-12-01
The aim of the present in vitro study was to assess the effect of bleaching agents on eroded and sound enamel specimens. Enamel specimens prepared from human permanent anterior teeth were incubated with different bleaching agents containing active ingredients as 7.5 or 13.5% hydrogen peroxide or 35% carbamide peroxide, ranging in pH from 4.9 to 10.8. The effect of the tooth whitening agents on surface roughness was tested for sound enamel surfaces as well as for eroded enamel specimens. To provoke erosive damage, the enamel specimens were incubated for 10 hours with apple juice (pH = 3.4). Afterwards, pretreated and untreated dental slices were incubated with one of the bleaching agents for 10 hours. The surface roughness (R(a)) of all enamel specimens (N = 80) was measured using an optical profilometric device. A descriptive statistical analysis of the R(a) values was performed. The study demonstrated that exposure to an acidic bleaching agent (pH = 4.9) resulted in a higher surface roughness (p = 0.043) than treatment with a high peroxide concentration (pH = 6.15). If the enamel surface was previously exposed to erosive beverages, subsequent bleaching may enhance damage to the dental hard tissue. Bleaching agents with a high concentration of peroxide or an acidic pH can influence the surface roughness of sound or eroded enamel. © 2010, COPYRIGHT THE AUTHORS. JOURNAL COMPILATION © 2010, WILEY PERIODICALS, INC.
Pintado-Palomino, Karen; Tirapelli, Camila
2015-01-01
Objective: This study aimed to evaluate in vitro the effect of formulations containing Biosilicate to treat enamel and dentin bovine samples exposed to dental bleaching agents. Materials and Methods: On enamel and dentin bleached with commercial gels containing 16% carbamide peroxide (CP) (14 days/4 h) or 35% hydrogen peroxide (single session/45 min), desensitizing dentifrices (Sensodyne®; experimental dentifrice of Biosilicate®; Odontis RX®; Sorriso®) were applied along 14 days and desensitizing pastes (Biosilicate®/water 1:1; Dessensebilize NanoP®; Bioglass type 45S5/water 1:1) were applied on days 1, 3, 7, 10 and 14. Distilled water was the control. Microhardness (MH) and roughness measurements were the variables measured on the samples before and after the treatments. Student's t-test analyzed differences before and after the treatments. Two-way analysis of variance and post-hoc Tukey test analyzed differences among the factors desensitizing, bleaching agents and substrate. Results: Tukey test showed no differences in roughness for both bleaching treatments and among the desensitizing agents (P > 0.05). Differences in MH appeared on enamel treated with in-home bleaching when control group (lower values) was compared with Sensodyne, Biosilicate dentifrice, Biosilicate paste, and Bioglass paste (higher values). Comparisons between desensitizing agents on dentin treated with both bleaching gels showed no statistical differences. Conclusions: The effect of formulations containing Biosilicate (Biosilicate dentifrice and paste) was significant in the MH of enamel bleached with 16% CP. PMID:25713487
The effect of different drinks on tooth color after home bleaching
Karadas, Muhammet; Seven, Nilgun
2014-01-01
Objective: This study evaluated the influence of coffee, tea, cola, and red wine staining on the color of teeth after home bleaching. Materials and Methods: A total of 45 samples were obtained from 45 sound maxillary central incisors. The home bleaching procedure was performed using 10% carbamide peroxide gel applied to the sample surface for a period of 6 h each day, for 14 days. After bleaching, baseline color measurements were taken, and the samples were immersed in four staining solutions (coffee, tea, cola, and red wine) or artificial saliva (n = 9). Following 15 min and 6 h of immersion on the first day and next day, respectively, the samples were washed with distilled water for 10 s. After 15 min, 6 h, 1 week, and 1 month immersions, the color values of each sample were remeasured and the color change values (∆E) were calculated. Color change analysis was performed using a spectrophotometer. The results were analyzed using analysis of variance and Tukey's honestly significant difference test (P <0.05). Results: Of all the staining solutions, the lowest ∆E values were observed with coffee staining versus artificial saliva (control group), for all time intervals evaluated after whitening. Although no statistically differences were observed between the coffee and control group at all the time points evaluated, there were statistically significant differences between the red wine, cola, and tea solutions. Conclusion: Following tooth whitening, patients should avoid drinks that cause tooth staining, particularly red wine, tea and cola. PMID:24966778
Kinetic release of hydrogen peroxide from different whitening products.
da Silva Marques, Duarte Nuno; Silveira, Joao Miguel; Marques, Joana Rita; Amaral, Joao Almeida; Guilherme, Nuno Marques; da Mata, António Duarte
2012-01-01
The objective of this in vitro study was to evaluate the kinetics of hydrogen peroxide (HP) release from five different bleaching products: VivaStyle® 10% fitted tray gel, VivaStyle® 30% in-office bleaching gel, VivaStyle® Paint-On Plus paint-on bleaching varnish, Opalescence PF® 10% carbamide peroxide gel and Trèswhite Supreme 10% HP gel. Each product was firstly titrated for its HP content by a described method. HP release kinetics was assessed by a modified spectrophotometric technique. One sample t test was performed to test for differences between the manufacturers' claimed HP concentrations and the titrated HP content in the whitening products. Analysis of variance plus Tamhane's post hoc tests and Pearson correlation analysis were used as appropriate. Values of P < 0.05 were taken as significant. Titrated HP revealed an increased content when compared to the manufacturer's specifications for all the products tested (P < 0.05), although only products from one manufacturer produced significantly higher results. All products presented a significant (P < 0.05) and sustained release of HP. However, the product with paint-on cellulose-based matrix resulted in significantly (P < 0.05) faster kinetics when compared to other products tested. These results are consistent with manufacturers' reduced recommended application times. The results of this study suggest that modifying the matrix composition may be a viable alternative to HP concentration increase, since this may result in faster release kinetics without exposure to high HP concentrations.
Tay, Lidia Yileng; Kose, Carlos; Herrera, Daniel Rodrigo; Reis, Alessandra; Loguercio, Alessandro Dourado
2012-08-01
This parallel, double-blind randomized clinical trial evaluated the 2-year bleaching efficacy and sensitivity produced by at-home (AH) and in-office (IO) bleaching therapies. 60 participants with tooth color darker than C2, without restorations in the anterior dentition and older than 18 years old, were randomly allocated into two groups to receive either IO with 35% hydrogen peroxide or AH with 16% carbamide peroxide. Color was recorded at baseline (BA); 1-week (1W); end of the treatment (ET); and 2 years (2Y) after bleaching, using the Vita Classical shade guide. The perception of TS was recorded on a 0-4 scale during and 2Y after bleaching. The variation in shade guide units (deltaSGU) from BA vs. 1W was compared to deltaSGU from BA vs. 2Y using paired t-test. The percentage of subjects who reported TS was evaluated by Fisher's exact test. The intensity of TS was evaluated by a Mann-Whitney test (alpha=0.05). Both bleaching techniques demonstrated equivalent and significant tooth color shade lightening. No significant color rebound occurred after 2Y for both techniques (P= 0.77 and 0.87, for AH and IO respectively). The absolute risk of TS was similar for IO and AH (P= 0.12), however the intensity of TS was significantly higher for IO (P= 0.001). No subjects reported sensitivity after 2Y.
Influence of surfactants on the effectiveness of bleaching gels.
Caneppele, Taciana Marco Ferraz; Torres, Carlos Rocha Gomes
2011-02-01
This study evaluated the influence of surfactants on the effectiveness of 35% hydrogen peroxide (HP) and 10% carbamide peroxide (CP) bleaching gels. One hundred and forty bovine teeth were used, which were stained by immersion in a coffee, red wine, and tobacco mixture for 7 days. At the end of this process, the color measurement at baseline was taken with the Vita Easyshade spectrophotometer. The teeth were divided into seven groups: (a) negative control (NC), (b) positive control for HP (PC-35), (c) HP + Tween 20 (T20-35), (d) HP + laurel sodium sulfate (LSS-35), (e) positive control for CP (PC-10), (f) CP + Tween 20 (T20-10), and (g) CP + laurel sodium sulfate (LSS-10). Group NC was kept in artificial saliva for 21 days. Groups PC-35, T20-35, and LSS 35 received three applications of bleaching gel for 10 min; the process was repeated after 7 days. Groups PC-10, T20-10, and LSS-10 received the gel for 8 h per day for 14 days. After the bleaching process, the final color was measured. The analysis of variance and Tukey tests showed statistically significant differences for the parameters of ∆L, ∆b, and ∆E of the HP gels with surfactant and positive control group (PC-35). Within the limits of this in vitro study, the addition of surfactants to HP bleaching gel increased the bleaching effectiveness.
Clinical comparison of Colgate Platinum Toothwhitening System and Rembrandt Gel Plus.
Kowitz, G M; Nathoo, S A; Rustogi, K N; Chmielewski, M B; Liang, L J; Wong, R
1994-01-01
A 2-week, three-cell study was conducted to evaluate the tooth-whitening efficacy of the Colgate Platinum Professional Toothwhitening System vs Rembrandt Gel Plus (a regimen of products consisting of a 10% carbamide peroxide gel, a whitening toothpaste, and a mouthrinse), and a placebo paste. Seventy subjects completed this parallel, single-blind, three-compartment, randomized clinical study. The subjects were balanced into two groups based on a minimal shade of A3 on the Vita shade guide and assigned a product. The duration of product usage was 1 hour twice daily for 2 weeks. Change in tooth color was measured by reflectance spectroscopy using a colorimeter. The readings were taken in the L*, a*, b* color space at the initiation, at 1 week, and at 2 weeks of the study. Calculation of color change (delta E) was performed using the color difference equation established by the Commission Internationale de L'Eclairage. Visual evaluation of shade changes was performed using the Vita shade guide. Results from this clinical study showed that Colgate Platinum was 77.7% more effective at tooth whitening after 1 week and 41.8% more effective after 2 weeks of treatment vs the Rembrandt regimen. Results showed that the Colgate product is significantly superior vs Rembrandt at increasing tooth whiteness (increase in delta E). Shade guide changes showed an overall improvement of 7.08 Vita tabs for the Colgate product and 5.12 Vita tabs for the Rembrandt regimen.
Efficacy of whitening oral rinses and dentifrices on color stability of bleached teeth
Karadas, Muhammet
2015-01-01
Abstract Objective: This study aimed to evaluate the effect of whitening toothpastes and mouthrinses on the color stability of teeth bleached with 16% carbamide peroxide (CP) after immersion in coffee solution. Materials and methods: Specimens obtained from bovine incisors were bleached with 16% CP for 14 days. After bleaching, the specimens were stained in coffee solution for 24 h and randomly divided into eight groups according to the following products (n = 10): distilled water (control group, DW), Scope White mouthrinse (SW), Crest 3D White mouthrinse (CWR), Crest 3D White toothpaste (CWT), Crest 3D White toothpaste and Crest 3D White mouthrinse (CWT + CWR), Listerine Whitening toothpaste (LWT), Listerine Whitening mouthrinse (LWR), and Listerine Whitening mouthrinse and Listerine Whitening toothpaste (LWR + LWT). Color measurements were conducted using a spectrophotometer. The data were assessed by analysis of variance for repeated measures and Tukey’s multiple comparison test (p < 0.05). Results: Immersion in coffee solution after bleaching caused perceptible staining on tooth specimens (ΔE > 3.46). The whitening effect of CWR on teeth stained after bleaching was significantly greater than that in the other groups (p < 0.001). Tooth whitening (ΔE) in each group showed no significant difference from 6 to 12 weeks (p > 0.05). The combination of mouthrinse and toothpaste did not increase the degree of tooth whitening. Conclusion: Whitening mouthrinse and toothpaste had similar effects on the control group in terms of whitening of teeth stained after bleaching. Nevertheless, Crest 3D White mouthrinse produced the greatest recovery whitening effect among all the products tested. PMID:28642898
Machado, Lucas Silveira; Anchieta, Rodolfo Bruniera; dos Santos, Paulo Henrique; Briso, André Luiz; Tovar, Nick; Janal, Malvin N; Coelho, Paulo Guilherme; Sundfeld, Renato Herman
2016-01-01
The objective of this split-mouth clinical study was to compare a combination of in-office and at-home dental bleaching with at-home bleaching alone. Two applications of in-office bleaching were performed, with one appointment per week, using 38% hydrogen peroxide. At-home bleaching was performed with or without in-office bleaching using 10% carbamide peroxide in a custom-made tray every night for 2 weeks. The factor studied was the bleaching technique on two levels: Technique 1 (in-office bleaching combined with home bleaching) and Technique 2 (home bleaching only). The response variables were color change, dental sensitivity, morphology, and surface roughness. The maxillary right and left hemiarches of the participants were submitted to in-office placebo treatment and in-office bleaching, respectively (Phase 1), and at-home bleaching (Phase 2) treatment was performed on both hemiarches, characterizing a split-mouth design. Enamel surface changes and roughness were analyzed with scanning electron microscopy and optical interferometry using epoxy replicas. No statistically significant differences were observed between the bleaching techniques for either the visual or the digital analyses. There was a significant difference in dental sensitivity when both dental bleaching techniques were used, with in-office bleaching producing the highest levels of dental sensitivity after the baseline. Microscopic analysis of the morphology and roughness of the enamel surface showed no significant changes between the bleaching techniques. The two techniques produced similar results in color change, and the combination technique produced the highest levels of sensitivity. Neither technique promoted changes in morphology or surface roughness of enamel.
Mineral loss and color change of enamel after bleaching and staining solutions combination.
de Araújo, Larissa Sgarbosa Napoleão; dos Santos, Paulo Henrique; Anchieta, Rodolfo Bruniera; Catelan, Anderson; Fraga Briso, André Luiz; Fraga Zaze, Ana Carolina Soares; Sundfeld, Renato Herman
2013-10-01
Pigments of food and beverages could affect dental bleaching efficacy. The aim of this investigation was to evaluate color change and mineral loss of tooth enamel as well as the influence of staining solutions normally used by adolescent patients undergoing home bleaching. Initial hardness and baseline color were measured on enamel blocks. Specimens were divided into five groups (n=5): G1 (control) specimens were kept in artificial saliva throughout the experiment (3 weeks); G2 enamel was exposed to 10% carbamide peroxide for 6 h daily, and after this period, the teeth were cleaned and stored in artificial saliva until the next bleaching session; and G3, G4, and G5 received the same treatments as G2, but after bleaching, they were stored for 1 h in cola soft drink, melted chocolate, or red wine, respectively. Mineral loss was obtained by the percentage of hardness reduction, and color change was determined by the difference between the data obtained before and after treatments. Data were subjected to analysis of variance and Fisher's test (α=0.05). G3 and G5 showed higher mineral loss (92.96 ± 5.50 and 94.46 ± 1.00, respectively) compared to the other groups (p ≤ 0.05). G5 showed high-color change (9.34 ± 2.90), whereas G1 presented lower color change (2.22 ± 0.44) (p ≤ 0.05). Acidic drinks cause mineral loss of the enamel, which could modify the surface and reduce staining resistance after bleaching.
Ghanbarzadeh, Majid; Akbari, Majid; Hamzei, Haniye
2015-01-01
Background There is little data regarding the effect of tooth whitening on microhardness of white spot lesions. This study was conducted to investigate the effect of home-bleaching and laser-assisted in-office bleaching on microhardness of demineralized enamel. Material and Methods Forty bovine incisors were selected and immersed in a demineralizing solution for 12 weeks to induce white spot lesions. Enamel blocks were prepared and randomly assigned to two groups of 20 each. The first group underwent home bleaching with 15% carbamide peroxide which was applied for 8 hours a day over a period of 15 days. In the second group, in-office bleaching was performed by 40% hydrogen peroxide and powered by irradiation from an 810 nm gallium-aluminum-arsenide (GaAlAs) diode laser (CW, 2W). This process was performed for 3 sessions every seven days, in 15 days. The specimens were stored in Fusayama Meyer artificial saliva during the experiment. Surface microhardness was assessed before and after the bleaching therapies in both groups. Results Microhardness decreased significantly following both home bleaching and laser-assisted in-office bleaching (p<0.05). There were no significant differences in hardness values among the two groups either before (p=0.131) or after (p=0.182) the bleaching procedures. Conclusions Tooth whitening through home bleaching or laser-assisted in-office bleaching can result in a significant reduction in microhardness of white spot lesions. Therefore, it is suggested to take protective measures on bleached demineralized enamel. Key words:White spot lesion, bleaching, laser, microhardness, demineralized enamel, home bleaching, in-office bleaching. PMID:26330939
Uthappa, Roshan; Suprith, M L; Bhandary, Shreetha; Dash, Sumit
2012-11-01
The purpose of the study was to compare two different commercial bleaching agents, Opalescence with Colgate Platinum, and 30% phosphoric acid used as aggressive agent on the morphology of human enamel. Ten freshly extracted, noncarious, human maxillary central incisors extracted for periodontal reasons were used in this study. The labial surface of the disinfected teeth were polished using a polishing paste with the help of rubber cup and a slow speed handpiece. Each tooth was sectioned at cement-enamel junction and the crown was separated into four specimens, all taken from labial surface. Group 1 was treated with Colgate Platinum for 7 hours, group 2 with Opalescence for 7 hours, group 3 was treated with 30% phosphoric acid for 30 seconds and group 4 was untreated and used as control. After the treatment period, the specimens were washed with normal saline and stored in sterile bottle and sealed. Photomicrographs obtained from the scanning electron microscopy (SEM) after surface treatments were examined for no alteration, slight alteration, moderate alteration and severe alterations. The specimens treated with commercial bleaching agents revealed no enamel surface morphologic alterations compared to control group. The specimen treated with phosphoric acid showed severe alterations. Ten percent carbamide peroxide evaluated in this study does not etch tooth enamel or alter enamel surface morphology as do conventional etching techniques. Carbamine peroxide is a safe and effective tooth whitening agent even when used for extended period of time. The enamel surface remains smooth which reduces caries due to plaque collection.
Efficacy of mouth rinses and toothpaste on tooth whitening.
Torres, C R G; Perote, L C C C; Gutierrez, N C; Pucci, C R; Borges, A B
2013-01-01
People increasingly desire tooth whitening. Considering the wide range of whitening products on the market, this study evaluated the efficacy of whitening toothpastes and mouth rinses compared with the 10% carbamide peroxide (CP) whitening gel. We obtained 120 cylindrical specimens from bovine teeth, which were darkened for 24 hours in a coffee solution. The color measurement was performed by a spectrophotometer using the CIE L*a*b* system, and specimens were divided into six groups according to the use of the following agents: group 1, conventional fluoridated toothpaste; group 2, Close Up White Now; group 3, Listerine Whitening; group 4, Colgate Plax Whitening; group 5, experimental mouth rinse with Plasdone; and group 6, 10% CP Whiteness Perfect. After the simulation of 12 weeks of treatment for groups 1 to 5 and 14 days of treatment for group 6, the specimens were subjected to a new color reading. Data were subjected to one-way analysis of variance (α=0.05), which showed significant differences among groups after 12 weeks for ΔE (p=0.001). Results of the Tukey test revealed that groups 3, 4, and 6 presented significantly higher color alteration than groups 1, 2, and 5. The whitening toothpaste Close Up White Now and the experimental mouth rinse with Plasdone showed similar color alteration as conventional toothpaste after a 12-week treatment simulation. These groups presented significantly lower color alteration compared with whitening mouth rinses Listerine and Colgate Plax Whitening, which showed similar results to those observed after 14 days of bleaching with 10% CP treatment.
Effect of Discharge Time on Plasma Electrolytic Borocarbonitriding of Pure Iron
NASA Astrophysics Data System (ADS)
Jin, Xiaoyue; Wu, Jie; Wang, Bin; Yang, Xuan; Chen, Lin; Qu, Yao; Xue, Wenbin
The plasma electrolytic borocarbonitriding (PEB/C/N) process on pure iron was carried out in 25% borax solution with glycerine and carbamide additives under different discharge time at 360V. The morphology and structure of PEB/C/N hardened layers were analyzed by SEM and XRD. The hardness profiles of hardened layers were measured by microhardness test. Corrosion behavior of PEB/C/N layers was evaluated by potentiodynamic polarization and electrochemical impedance spectroscopy (EIS). Their wear performance was carried out using a pin-disc friction and wear tester under dry sliding test. The PEB/C/N samples mainly consisted of α-Fe, Fe2B, Fe3C, FeN, FeB, Fe2O3 and Fe4N phases, and the Fe2B phase was the dominant phase in the boride layer. It was found that the thickness of boride layer increased with the discharge time and reached 14μm after 60min treatment. The microhardness of the boride layer was up to 2100HV, which was much higher than that of the bare pure iron (about 150HV). After PEB/C/N treatment, the corrosion resistance of pure iron was slightly improved. The friction coefficient of PEB/C/N treated pure iron decreased to 0.129 from 0.556 of pure iron substrate. The wear rate of the PEB/C/N layer after 60min under dry sliding against ZrO2 ball was only 1/10 of that of the bare pure iron. The PEB/C/N treatment is an effective way to improve the wear behavior of pure iron.
Oliveira de Oliveira, Laura Beatriz; Faccin Bampi, Vinícius; Ferreira Gomes, Carolina; Braga da Silva, Jefferson Luis; Encarnação Fiala Rechsteiner, Sandra Mara
2014-01-01
The word angiogenesis indicates the formation of new vascular segments from existing vessels such as capillaries and venules. Blood vessel formation in tumors is the result of rapid, disorganized vascular growth through two distinct mechanisms: sprouting and intussusceptive angiogenesis. The objective of this study was to elucidate the morphological aspects of these two vascular growth mechanisms in oral squamous cell carcinoma induced in hamster buccal pouch. Eight Syrian golden hamsters had their right buccal pouch treated with DMBA 0.5% and 10% carbamide peroxide for 90 days in order to produce squamous cell carcinoma in this site. Next, buccal pouches of the animals were submitted to the vascular corrosion technique and then analyzed by scanning electron microscopy. The vascular figures of sprouts were observed in the entire vascular network of the buccal pouches, as opposed to the intussusceptive angiogenesis that was predominantly observed in the sub-epithelial network. It was possible to differentiate the figures of sprouts from artifacts by the analysis of the blind ending of these structures. Intussusceptive angiogenesis was identified by the presence of holes trespassing the lumen of the capillaries. Vascular expansion occurred through intussusceptive angiogenesis in two ways: by the fusion of the pillars to form a new capillary and, by increasing the girth of the pillar to form meshes. The method of corrosion associated with scanning electron microscopy proved to be an excellent tool to study the two types of angiogenesis in oral squamous cell carcinoma in the hamster buccal pouch. © 2013 Wiley Periodicals, Inc.
Sundfeld, Daniel; Pavani, Caio Cesar; Schott, Timm Cornelius; Machado, Lucas Silveira; Pini, Núbia Inocêncya Pavesi; Bertoz, André Pinheiro de Magalhães; Sundfeld, Renato Herman
2018-04-20
The present dental bleaching case report describes a new method that precisely quantifies the daily wearing-times of the bleaching product by inserting a microsensor in the acetate custom tray. The bleaching efficacy was also discussed since the patient was previously submitted to enamel microabrasion. The patient was submitted to enamel microabrasion in 1987, and bleaching treatment was performed in 2005. In 2017, re-bleaching was executed using 10% peroxide carbamide. The electronic microsensor, TheraMon (TheraMon® microelectronic system; Sales Agency Gschladt, Hargelsberg, Austria), was embedded in the labial region of the upper and lower acetate trays to evaluate the wearing-times of the acetate trays/bleaching product. The patient was instructed to wear the tray for 6 to 8 h/day while sleeping. After 24 days of bleaching treatment, the data obtained from the TheraMon electronic devices was collected and interpreted. The patient did not entirely follow the bleaching treatment as recommended, as there was no evidence of use of the upper and lower trays for some days; additionally, the bleaching product was used for shorter and longer periods than was instructed. The TheraMon microeletronic device precisely measured the wearing-times of the acetate tray/bleaching product during the bleaching treatment. Teeth submitted to enamel microabrasion presented with a healthy clinical appearance after 30 years. Measuring the length and frequency of use of an acetate tray/bleaching product can be important to clinicians and patients for obtaining a controlled and adequate bleaching treatment.
Santos, Luciane Geanini Pena Dos; Felippe, Wilson Tadeu; Souza, Beatriz Dulcineia Mendes de; Konrath, Andrea Cristina; Cordeiro, Mabel Mariela Rodríguez; Felippe, Mara Cristina Santos
2017-01-01
To assess tooth crown's color after intracanal treatment with triple antibiotic paste (TAP) or calcium hydroxide (CH); cervical sealing with glass ionomer cement (GIC) or mineral trioxide aggregate (MTA); and bleaching with carbamide peroxide. After pulp removal and color spectrophotometer measurement, 50 bovine incisors were divided into 4 experimental groups and one control (untreated). Experiments were performed in phases (Ph). Ph1: TAP (ciprofloxacin, metronidazole, minocycline), TAPM (ciprofloxacin, metronidazole, amoxicillin), DAP (ciprofloxacin, metronidazole), or CH treatment groups. After 1 and 3 days (d); 1, 2, 3 weeks (w); and 1, 2, 3 and 4 months (m), color was measured and medications were removed. Ph2: GIC or MTA cervical sealing, each using half of the specimens from each group. Color was assessed after 1d, 3d; 1w, 2w, 3w; 1m and 2m. Ph3: Two bleaching sessions, each followed by color measurement. Data were analyzed with ANOVA and post-hoc Holm-Sidak method. Ph1: Specimens of TAP group presented higher color alteration (ΔE) mean than those of TAPM group. No significant difference was found among TAP or TAPM and CH, DAP or Control groups. Ph2: cervical sealing materials showed no influence on color alteration. Ph3: Different ΔE means (from different groups), prior to bleaching, became equivalent after one bleaching session. TAP induces higher color alteration than TAPM; color alteration increases over time; cervical sealing material has no influence on color alteration; and, dental bleaching was able to recover, at least partially, the tooth crown's color.
Effect of different bleaching strategies on microhardness of a silorane-based composite resin.
Bahari, Mahmoud; Savadi Oskoee, Siavash; Mohammadi, Narmin; Ebrahimi Chaharom, Mohammad Esmaeel; Godrati, Mostafa; Savadi Oskoee, Ayda
2016-01-01
Background. Dentists' awareness of the effects of bleaching agents on the surface and mechanical properties of restorative materials is of utmost importance. Therefore, this in vitro study was undertaken to investigate the effects of different bleaching strategies on the microhardness of a silorane-based composite resin. Methods. Eighty samples of a silorane-based composite resin (measuring 4 mm in diameter and 2 mm in thickness) were prepared within acrylic molds. The samples were polished and randomly assigned to 4 groups (n=20). Group 1 (controls) were stored in distilled water for 2 weeks. The samples in group 2 underwent a bleaching procedure with 15% carbamide peroxide for two weeks two hours daily. The samples in group 3 were bleached with 35% hydrogen peroxide twice 5 days apart for 30 minutes each time. The samples in group 4 underwent a bleaching procedure with light-activated 35% hydrogen peroxide under LED light once for 40 minutes. Then the microhardness of the samples was determined using Vickers method. Data were analyzed with one-way ANOVA and post hoc Tukey tests (P < 0.05). Results. All the bleaching agents significantly decreased microhardness compared to the control group (P < 0.05). In addition, there were significant differences in microhardness between groups 2 and 4 (P = 0.001) and between groups 3 and 4 (P<0.001). However, no significant differences were detected in microhardness between groups 2 and 3 (P > 0.05). Conclusion. Bleaching agents decreased microhardness of silorane-based composite resin restorations, the magnitude of which depending on the bleaching strategy used.
Sever, Ivan; Klaric, Eva; Tarle, Zrinka
2016-07-01
Dental microhardness experiments are influenced by unobserved factors related to the varying tooth characteristics that affect measurement reproducibility. This paper explores the appropriate analytical tools for modeling different sources of unobserved variability to reduce the biases encountered and increase the validity of microhardness studies. The enamel microhardness of human third molars was measured by Vickers diamond. The effects of five bleaching agents-10, 16, and 30 % carbamide peroxide, and 25 and 38 % hydrogen peroxide-were examined, as well as the effect of artificial saliva and amorphous calcium phosphate. To account for both between- and within-tooth heterogeneity in evaluating treatment effects, the statistical analysis was performed in the mixed-effects framework, which also included the appropriate weighting procedure to adjust for confounding. The results were compared to those of the standard ANOVA model usually applied. The weighted mixed-effects model produced the parameter estimates of different magnitude and significance than the standard ANOVA model. The results of the former model were more intuitive, with more precise estimates and better fit. Confounding could seriously bias the study outcomes, highlighting the need for more robust statistical procedures in dental research that account for the measurement reliability. The presented framework is more flexible and informative than existing analytical techniques and may improve the quality of inference in dental research. Reported results could be misleading if underlying heterogeneity of microhardness measurements is not taken into account. The confidence in treatment outcomes could be increased by applying the framework presented.
Rahul, M; Kumar, P Anil; Nair, Amal S; Mathew, Shino; Amaladas, Antony Shijoy; Ommen, Anna
2017-01-01
This study aimed to evaluate the effects of at-home and in-office bleaching on the shear bond strength (SBS) of metal, ceramic, and composite orthodontic brackets and to compare their SBSs. A total of 96 human lower premolar teeth were used for this study. Six teeth were used for scanning electron microscopic study while the remaining ninety were divided into three equal groups. Each group was further subdivided into three subgroups with ten samples each. Three protocols were used. In the at-home bleaching group (n = 30), opalescence non-PF (potassium nitrate and fluoride) bleaching agent (10% carbamide peroxide) was applied onto the teeth daily for 14 days and left for 8 h each day. Teeth in the in-office group (n = 30) were treated twice in consecutive days with Opalescence boost PF (40% hydrogen peroxide). After bleaching, the specimens were stored in distilled water for 1 day before bonding. SBS testing was performed on all teeth using Instron universal testing machine. Analysis of variance indicated a significant difference (P < 0.005) among the groups. Maximum SBS was shown by ceramic brackets in control group (Ib) and minimum was shown by composite brackets of in-office bleached group (IIIc). The results showed that at-home bleaching did not affect the SBS significantly whereas in-office bleaching reduced SBS of metal, ceramic, and composite brackets significantly. It is preferable to use metal or ceramic brackets than composite brackets for bonding 24 h after bleaching.
Shamsedin, Mana; Arash, Valiollah; Jahromi, Masoud Babaei; Moghadamnia, Ali Akbar; Kamel, Manouchehr Rahmati; Ezoji, Fariba; Bijani, Ali; Kavoli, Samira; Ghasemi, Tania; Ramezani, Gholamhossein
2017-01-01
To evaluate comparatively the effect of quercetin on postbleaching shear bond strength (SBS) and adhesive remnant index (ARI). Intact maxillary premolars were divided randomly into 12 groups of 10 each: (1) bonding the bracket immediately after bleaching, (2) bonding 1 week after bleaching, (3-8) application of three experimental concentrations of quercetin (0.1%, 0.5%, and 1%) at two time durations (5 and 10 min), (9-10) application of the solvent of quercetin at two time periods (5 and 10 min), (11) application of 10% sodium ascorbate for 10 min, and (12) bonding the brackets on nonbleached teeth. Bleaching was performed using 15% carbamide peroxide gel for 5 days (6 h daily). After incubation and thermocycling, the SBS of brackets was measured. The ARI too was recorded at ×20. The data were analyzed statistically (α =0.05). Bleaching reduced the SBS below 10 Megapascal (MPa) level ( P < 0.05) while all the postbleaching treatments (except the application of the solvent of quercetin) recovered the SBS back to values greater than 10 MPa ( P < 0.05) and also back to nonbleached SBS levels ( P > 0.01). All eight postbleaching treatments had rather similar efficacies ( P = 0.1396). The concentration of quercetin (beta = 0.259, P = 0.042) but not its duration (beta = 0.213, P = 0.093) significantly improved its efficacy. Bleaching can weaken the bond strength of orthodontic brackets below acceptable levels. The application of quercetin or Vitamin C or delaying the bracket bonding improved the postbleaching SBS.
Unusual extrinsic staining following microabrasion in a girl with amelogenesis imperfecta.
Rogers, H J; Yesudian, G; Rodd, H D
2016-08-01
Developmental defects of enamel (DDE), such as amelogenesis imperfecta (AI), may present with tooth discolouration that is of aesthetic concern to the affected individual. Children and young people with DDE may therefore seek dental interventions to improve their dental appearance. The most commonly employed approaches include microabrasion, bleaching and/or placement of composite resin veneers. A 13-year-old girl with hypomature AI requested treatment for the 'marks' on her teeth which were having a negative impact on her social interactions. Clinical examination revealed generalised dense white opacities, and a microabrasion approach was performed on 11, 12 and 13 using a commercial preparation of 6.6 % hydrochloric acid. Concerningly, the girl's father phoned the next day reporting that his daughter's teeth had turned 'orange'. An urgent review revealed that the treated teeth had indeed become an orange colour. Further enquiry found that the patient had eaten a tomato pizza immediately after her dental treatment and this was believed to have caused the severe extrinsic staining. The patient was provided with a 16 % carbamide peroxide preparation for night-time use in a laboratory-made tray. A 2-week review revealed complete resolution of the staining. Direct composite resin restorations were subsequently provided for the girl's maxillary anterior teeth to achieve an optimal cosmetic result and she has remained pleased with her dental appearance. Clinicians should be aware of the potential for extrinsic staining following microabrasion or tooth bleaching. Patients should be advised against consuming coloured food and drink for at least 48 h after their treatment.
Surface discoloration of composite resins: Effects of staining and bleaching.
Poggio, Claudio; Beltrami, Riccardo; Scribante, Andrea; Colombo, Marco; Chiesa, Marco
2012-09-01
The purpose of this in vitro study was to evaluate surface discoloration of three microhybrid composite resins (Esthet•X HD, Clearfil AP-X, Gradia Direct) and five nanohybrid composite resins (Ceram•X, GC Kalore, G-aenial, Grandio, GrandioSO), after staining and bleaching procedures. The composite resins were polymerized with a curing light (Celalux II, Voco, Cuxhaven, Germany) into 160 silicon molds (6,4 mm in diameter and 2 mm in thickness) to obtain identical specimens. Twenty samples for each composite resin were prepared. The specimens were polished using an automated polishing machine with the sequence of 600-, 800-, 1000-grit abrasive paper under water irrigation. The specimens were immersed in tea and distilled water: the specimens were dipped for 20 min, once a day (every 24 h), for 14 days into the drinks. The specimens were then bleached with carbamide peroxide at 17% (Perfect Bleach-Voco). The color of specimens was measured with a spectrophotometer according to the CIE L(*)a(*)b(*) system after light-polymerization of composite resin specimens, after 7 days, after 14 days, and after bleaching. The color difference h index (DEab(*)) between each measurement was calculated. Statistical analysis was made using analysis of variance (ANOVA). All specimens showed a significant increase in staining with a similar trend and no significant differences between microhybrid and nanohybrid composite resins. After whitening procedures, materials tested showed both significant and unsignificant differences of the h index. Microhybrid and nanohybrid composite resins had similar in vitro surface discoloration in tea. After bleaching, discoloration was removed from some composite resins tested.
Surface discoloration of composite resins: Effects of staining and bleaching
Poggio, Claudio; Beltrami, Riccardo; Scribante, Andrea; Colombo, Marco; Chiesa, Marco
2012-01-01
Background: The purpose of this in vitro study was to evaluate surface discoloration of three microhybrid composite resins (Esthet•X HD, Clearfil AP-X, Gradia Direct) and five nanohybrid composite resins (Ceram•X, GC Kalore, G-aenial, Grandio, GrandioSO), after staining and bleaching procedures. Materials and Methods: The composite resins were polymerized with a curing light (Celalux II, Voco, Cuxhaven, Germany) into 160 silicon molds (6,4 mm in diameter and 2 mm in thickness) to obtain identical specimens. Twenty samples for each composite resin were prepared. The specimens were polished using an automated polishing machine with the sequence of 600-, 800-, 1000-grit abrasive paper under water irrigation. The specimens were immersed in tea and distilled water: the specimens were dipped for 20 min, once a day (every 24 h), for 14 days into the drinks. The specimens were then bleached with carbamide peroxide at 17% (Perfect Bleach-Voco). The color of specimens was measured with a spectrophotometer according to the CIE L*a*b* system after light-polymerization of composite resin specimens, after 7 days, after 14 days, and after bleaching. The color difference h index (DEab*) between each measurement was calculated. Statistical analysis was made using analysis of variance (ANOVA). Results: All specimens showed a significant increase in staining with a similar trend and no significant differences between microhybrid and nanohybrid composite resins. After whitening procedures, materials tested showed both significant and unsignificant differences of the h index. Conclusions: Microhybrid and nanohybrid composite resins had similar in vitro surface discoloration in tea. After bleaching, discoloration was removed from some composite resins tested. PMID:23559921
The effect of enamel bleaching on the shear bond strengths of metal and ceramic brackets.
Oztaş, E; Bağdelen, G; Kiliçoğlu, H; Ulukapi, H; Aydin, I
2012-04-01
The aim of this study was to evaluate the effects of bleaching and delayed bonding on the shear bond strengths of metal and ceramic brackets bonded with light and chemically cure composite resin to human enamel. One hundred and twenty extracted human premolar teeth were randomly divided into three groups of 40 each. The first two groups were bleached with 20 per cent carbamide peroxide (CP) at-home bleaching agent. No bleaching procedures were applied to the third group and served as control. The first two and control groups were divided into equal subgroups according to different adhesive-bracket combinations. Specimens in group 1 (n = 40) were bonded 24 hours after bleaching process was completed while the specimens in group 2 (n = 40) were bonded 14 days after. The specimens in all groups were debonded with a Universal testing machine while the modified adhesive remnant index was used to evaluate fracture properties. No statistically significant differences were found between the shear bond strengths of metal and ceramic brackets bonded to bleached enamel after 24 hours, 14 days, and unbleached enamel with light or chemical cure adhesives (P > 0.05). The mode of failure was mostly at the bracket/adhesive interface and cohesive failures within the resin were also observed. Our findings indicated that at-home bleaching agents that contain 20 per cent CP did not significantly affect the shear bond strength of metal and ceramic orthodontic brackets to enamel when bonding is performed 24 hours or 14 days after bleaching.
NASA Astrophysics Data System (ADS)
Emnova, E. E.; Daraban, O. V.; Bizgan, Ya. V.; Toma, S. I.; Vozian, V. I.; Iacobuta, M. D.
2015-05-01
Three varieties (Aura, Magie, and Indra) of soybean ( Glycine max [L.] Merr.) were grown in a small-plot experiment on a calcic chernozem with the application of two types of nitrogen fertilizers: ammonium nitrate (Nan) or carbamide (Nc). These fertilizers at the rate of 20 kg N/ha were applied before sowing together with potassium phosphate (60 kg P2O5/ha). The microbial nitrification capacity and the activity of enzymes related to the nitrogen cycle (urease and nitrate reductase) were measured in the rhizosphere (0-20 cm) at the stage of soybean flowering. It was determined that the biological (enzyme) activity of the calcic chernozem in the soybean rhizosphere was more intense on the plots with the Nan fertilizer than on the plots with the Nc fertilizer. The urease activity depended on the type of nitrogen fertilizer (Nan or Nc) under the conditions of soil water deficiency. In the soil under the Aura variety, the urease activity was significantly lower in the treatments with Nc application, and this was accompanied by a decrease in the crop yield. The nitrification capacity of the calcic chernozem was generally low; in the case of the Nc fertilizer, it was significantly lower than in the case of the Nan fertilizer. The nitrate reductase activity of the soil was also lower in the case of the Nc fertilizer. Each of the three soybean varieties had its own response to changes in the nitrogen nutrition aimed at improving the soybean tolerance to fluctuations in the soil water content during the growing season.
Association Between In-Office And At-Home Tooth Bleaching: A Single Blind Randomized Clinical Trial.
Rodrigues, João Lima; Rocha, Patrícia Souza; Pardim, Silvia Letícia de Souza; Machado, Ana Cláudia Vieira; Faria-E-Silva, André Luis; Seraidarian, Paulo Isaías
2018-01-01
This controlled randomized clinical trial evaluated the effect of associating at-home and in-office bleaching procedures on tooth sensitivity (TS) and bleaching effectiveness. Forty patients subjected to on session of in-office bleaching with 38% peroxide hydrogen. Subsequently, the patients were randomly allocated to receive a second session of in-office bleaching or to use a tray containing 10% carbamide peroxide delivered during 7 consecutive days. The worst TS score reported during or after each bleaching procedure was recorded using a verbal rating scale and TS risk (score different from 0) was calculated. Color changes were measured 7 days after each in-office session (for patients receiving in-office procedures only) or after the end of at-home bleaching (for the combined protocol), and 6 months after the last procedure for both bleaching protocols. Color was assessed by a spectrophotometer and by color match with the Vita Classical and Bleach guide scales. Statistical analyses were carried out to assess possible differences between the protocols regarding the outcomes and to analyze the effect of time of assessment on color changes. The bleaching protocol did not affect the risk for and the maximum level of TS reported, irrespective of the time of assessment. In the color evaluation, the bleaching protocol also did not affect the ultimate tooth color. In conclusion, after one in-office bleaching session, there was no difference in bleaching effectiveness and TS between performing a second in-office session and associating it with 1-week at-home bleaching.
Effects of in-office bleaching on human enamel and dentin. Morphological and mineral changes.
Llena, Carmen; Esteve, Irene; Forner, Leopoldo
2018-05-01
The effects of HP-based products upon dental enamel and dentin are inconclusive. To evaluate changes in micromorphology and composition of calcium (Ca) and phosphate (P) in enamel and dentin after the application of 37.5% hydrogen peroxide (HP) and 35% carbamide peroxide (CP) METHODS: Crowns of 20 human teeth were divided in two halves. One half was used as control specimen and the other as experimental specimen. The control specimens were kept in artificial saliva, and the experimental specimens were divided into four groups (n=5 each): group 1 (enamel HP for 45min); group 2 (dentin HP for 45min); group 3 (enamel CP for 90min); and group 4 (dentin CP for 90min). The morphological changes were evaluated using confocal laser scanning microscopy (CLSM), while the changes in the composition of Ca and P were assessed using environmental scanning electron microscopy combined with a microanalysis system (ESEM+EDX). The results within each group and between groups were compared using the Wilcoxon test and Mann-Whitney U-test, respectively (p<0.05). Similar morphological changes in the enamel and no changes in dentin were assessed with both products. Ca and P decreased in enamel and dentin, without significant differences between them or with respect to their control specimens (p>0.05). When bleaching products with a neutral pH are used in clinical practice, both, the concentration and the application time should be taken into account in order to avoid possible structural and mineral changes in enamel and dentin. Copyright © 2018 Elsevier GmbH. All rights reserved.
Topically applied hypericin exhibits skin penetrability on nude mice.
Li, Zhuo-Heng; Li, Yuan-Yuan; Hou, Min; Yang, Tao; Lu, Lai-Chun; Xu, Xiao-Yu
2018-06-13
Hypericin, a powerful natural photosensitizer in photodynamic therapy (PDT), is suitable for treating skin diseases involving excess capillary proliferation. In the present study, we aimed to evaluate the skin penetrability of topically applied hypericin, expecting a reduced risk of prolonged skin photosensitivity, which often occurs after systemic administration. Firstly, the Franz diffusion cell assays were performed to evaluate the penetration effects of different enhancers, including menthol, propylene glycol, camphanone, azone, and carbamide. In view of above evaluation results, we selected menthol as the enhancer in the subsequent in vivo studies. The setting groups were as follows: the blank control group, the light-exposure control group, the gel-base control group, the hypericin gel group, and a hypericin gel-containing menthol group. Except for the blank control, all other animals were irradiated by a LED light. Then, fluorescence microscopy was performed to examine the distribution of hypericin in the skin of nude mouse. Macroscopic and microscopic analyses were also carried out to detect pathological changes in the skin after topical hypericin-PDT treatment. Immunohistochemistry was used to determine the expression change of PECAM-1. As shown in the results, menthol facilitated hypericin penetrate the skin of nude mice most. The results of in vivo assays revealed that hypericin penetrated nude mouse skin, spread to the dermis, and resulted in obvious photosensitivity reaction on the dermal capillaries. Moreover, skin injured by the photosensitive reaction induced by hypericin-PDT treatment was replaced by normal skin within 7 days. We concluded that topical applied hypericin could penetrate nude mouse skin well and has a great potential in PDT treatment of skin diseases.
Gouveia, Thayla Hellen Nunes; Públio, Juliana do Carmo; Ambrosano, Glaucia Maria Bovi; Paulillo, Luís Alexandre Maffei Sartini; Aguiar, Flávio Henrique Baggio; Lima, Débora Alves Nunes Leite
2016-01-01
To evaluate the influence of 16% carbamide peroxide (CP) containing different thickeners on the physical characteristics of a nanocomposite resin submitted or not to accelerated artificial aging (AAA). One hundred samples were randomly distributed into two groups (n = 50) according to AAA. Each group was divided into 5 subgroups (n = 10) depending on the bleaching/thickener treatment: CP + carbopol, CP + natrosol, carbopol, natrosol, and no treatment (control). The physical properties tested were color (ΔE), gloss (GU), mean roughness (Ra), and Knoop microhardness (KHN). The resin surface was performed with atomic force microscopy (AFM). The color (variable Δ E) was assessed with two-way analysis of variance (ANOVA) and additionally with Tukey's and Dunnett's tests, the roughness values were submitted to Kruskal-Wallis, Dunn's, and Mann-Whitney's tests. Data on gloss and KHN were submitted to two-way ANOVA and Tukey's test (α = 0.05). Among the physical properties evaluated, CP + carbopol promoted a reduction in composite microhardness only, thus differing statistically from the controls. As for CP + natrosol, such a change was not observed. The aging process reduced all the physical properties, thus differing statistically from the nonaging group. CP + carbopol increased the roughness and decreased the gloss of aged resins, whereas natrosol reduced gloss only, which differed statistically from the controls. AFM showed evidence of the loss of organic matrix and exposure to load particles in the aged samples. Therefore, the replacement of carbopol with natrosol provided maintenance of the composite microhardness following bleaching. The aging process reduced the physical properties evaluated, and some changes were enhanced by the application of bleaching.
Bhattarai, Shanta Raj; Khalil, Khalil Abdel-Razek; Dewidar, Montasser; Hwang, Pyoung Han; Yi, Ho Keun; Kim, Hak Yong
2008-08-01
Porous metals are attractive due to its unique physical, mechanical, and new bone tissue ingrowth properties. In the present study, the production of highly porous Ti-6Al-4V parts by powder metallurgical technology and subsequently it's uses in in vitro bone tissue engineering is described. A space-holder method using carbamide with different particle size to produce parts with porosities between 35 and 70% were applied. The compressive strength and Young's modulus of porous Ti-6Al-4V were determined. Results indicated that stress and Young's modulus decrease with increasing porosity and pore size. The porous parts are characterized by scanning electron microscopy. Furthermore, study was to investigate the effects of three different porosities of porous Ti-6Al-4V (35, 50, and 70%) on proliferation, differentiation, and cell-matrix interaction of mouse osteoblast-like cells, MC-3T3. Results showed that the cell proliferation was significantly (p < 0.05) higher on 70% porous Ti-6Al-4V. However, synthesis of different types of extra cellular matrix proteins was also more abundant on 70% porous Ti-6Al-4V than 35 and 50% porous Ti-6Al-4V disk except some specific proteins. An increase in alkaline phosphate activity was significantly (p < 0.05) higher on 70 and 50% porous Ti-6Al-4V disk after 12 days of MC-3T3 cells incubation. Above all, results indicated that porosity (nearly 70%) of porous Ti-6Al-4V topography affects proliferation and differentiation of osteoblast-like MC-3T3 cells. The results showed that this novel process is a promise to fabricate porous biomaterials for bone implants.
Dietschi, Didier; Benbachir, Nacer; Krejci, Ivo
2010-06-01
Various bleaching modalities are now offered to patients, either monitored by the dental office or self-directed, for which relative efficiency is unknown. The aim of this in vitro study was to evaluate the ability of bleaching products and protocols to lighten enamel and dentin. Bovine tooth specimens of standardized thickness (2.5 +/- 0.025 mm with similar dentin and enamel thickness) were prepared and stained with whole blood and hemolysate before being submitted to seven supervised or self-directed bleaching regimens: tray-based bleaching using 10% (Opalescence, Ultradent; Nite White, Discus Dental) or light-activated 30% (Metatray, Metatray) carbamide peroxide (CP); 6% (Zoom, Discus Dental) or 9% (TresWhite, Ultradent) hydrogen peroxide (HP); strips (Whitening Strips, Oral B-Rembrandt); and paint-on gel (Paint on Plus, Ivoclar Vivadent) containing 8.1% and 6% HP, respectively. Colorimetric measurements were performed on each specimen side, according to the CIE L*a*b* system, before and after staining, as well as after 5, 10, and the recommended number of bleaching applications. Color change after recommended number of applications (DEr) varied from 15.72 (Metatray) to 29.67 (Nite White) at enamel and 14.91 (Paint on Plus) to 41.43 (Nite White) at dentin side; Nite White (10% CP) and TresWhite (9% HP) were more effective than Metatray (30% CP) and Paint on Plus (6% HP) after 5 or the recommended number of applications. In this in vitro study based on bovine teeth, tray-based systems produced the faster and better bleaching effect, regardless of the product and concentration used, at both enamel and dentin sides.
Clinical efficacy of a bleaching enzyme-based toothpaste. A double-blind controlled clinical trial.
Llena, Carmen; Oteo, Carlos; Oteo, Jesús; Amengual, José; Forner, Leopoldo
2016-01-01
To assess the efficacy of a bleaching enzyme-based toothpaste. A randomized clinical trial was carried out, comprising 48 participants with teeth exhibiting color A3 or higher according to the Vita Classical guide. One-half of the sample received the bleaching enzyme-based toothpaste (White Kin(®)), while the other received placebo toothpaste. Both products were supplied in identical containers and had the same composition except for the active components. The teeth color was measured with a spectrophotometer. The patients were instructed to brush their teeth three times a day during 3 min with the assigned product, during 12 weeks. The color measurements were repeated after 3, 6, 9 and 12 weeks of treatment. Color variation was based on the CIE L*a*b* coordinates, ΔE and the EW index. The relationship of these variables at different observation times were performed using a generalized estimating equations model, which evaluated the effect of treatment, time and interaction. The patients using the bleaching enzyme-based toothpaste showed an increase in lightness (80.14 -treatment- versus 79.25 -control group-) and a reduction in component b*. ΔE was found higher in the treatment group (p=0.064), close to statistical significance. The bleaching enzyme-based toothpaste could be potentially efficient in the modification in tooth color progressing from the third to ninth week of treatment, tending to stabilize after the ninth week. A very low carbamide peroxide concentration, with the incorporation of lactoperoxidase, tooth paste, tends to offer clinically satisfactory results, in terms of modifications in tooth color, nevertheless no significant differences were founded when compared to the control group, with an oral hygiene controlled along the study. Copyright © 2015 Elsevier Ltd. All rights reserved.
Torabi, Kianoosh; Rasaeipour, Sasan; Ghodsi, Safoura; Khaledi, Amir Ali Reza; Vojdani, Mahroo
2014-07-01
The exponential usage of esthetic restorative materials is beholden to society needs and desires. Interaction between the bleaching agents and the esthetic restorative materials is of critical importance. This in vitro study has been conducted to evaluate the effect of a home bleaching agent, carbamide peroxide (CP) 38%, on the microhardness of the fiber reinforced composite (FRC), overglazed, autoglazed, or polished porcelain specimens. For overglazed, autoglazed, polished ceramics and also FRC cylindrical specimens (n = 20 per group) were prepared. The specimens were stored in distilled water at 37°C for 48 hours prior to testing. Six samples from each group were selected randomly as negative controls which were stored in distilled water at 37°C that was changed daily. CP 38% was applied on the test specimens for 15 minutes, twice a day for 14 days. By using Knoop-microhardness tester microhardness testing for baseline, control and test specimens was conducted. Data were statistically analyzed using paired t-test, Mann-Whitney test, and Kruskal-Wallis test. Home bleaching significantly decreased the surface microhardness of all the test samples (p < 0.05), whereas the control groups did not show statistically significant changes after 2 weeks. The polished porcelain and polished composite specimens showed the most significant change in microhard-ness after bleaching process (p < 0.05). Although the type of surface preparation affects the susceptibility of the porcelain surface to the bleaching agent, no special preparation can preclude such adverse effects. The contact of home bleaching agents with esthetic restorative materials is unavoidable. Therefore protecting these restorations from bleaching agents and reglazing or at least polishing the restorations after bleaching is recommended.
The Influence of Post Bleaching Treatments in Stain Absorption and Microhardness
Moosavi, Horieh; Darvishzadeh, Fatemeh
2016-01-01
Objectives: This study investigated the effects of post bleaching treatments to prevent restaining and the change of enamel surface microhardness after dental bleaching in vitro. Methods: Sixty intact human incisor teeth were stained in tea solution and randomly assigned into four groups (n=15). Then samples were bleached for two weeks (8 hours daily) by 15% carbamide peroxide. Tooth color was determined both with a spectrophotometer and visually before bleaching (T1) and immediately after bleaching (T2). Next, it was applied in group 1 fluoride (Naf 2%) gel for 2 minutes, and in group 2 a fractional CO2 laser (10 mJ, 200 Hz, 10 s), and in group 3, nanohydroxyapatite gel for 2 minutes. The bleached teeth in group 4 remained untreated (control group). Then teeth placed in tea solution again. Color examinations were repeated after various post bleaching treatments (T3) and restaining with tea (T4) and color change values recorded. The microhardness was measured at the enamel surface of samples. Data was analyzed using ANOVA, Tukey HSD test and Dunnett T3 (α = 0.05). Results: Directly after bleaching (ΔE T3-T2), the treatment with nanohydroxyapatite showed significantly the least color lapse in colorimetric evaluation. In experimental groups, the color change between T3 and T4 stages (ΔE T4-T3) was significantly lower than control group (P < 0.05). Different methods of enamel treatment caused a significant increase in surface microhardness compared to control group (P < 0.05). Significance: Application of fluoride, fractional CO2 laser and nanohydroxyapatite as post bleaching treatments are suggested for prevention of stain absorption and increasing the hardening of bleached enamel. PMID:27099635
High levels of hydrogen peroxide in overnight tooth-whitening formulas: effects on enamel and pulp.
Pugh, George; Zaidel, Lynette; Lin, Nora; Stranick, Michael; Bagley, Daniel
2005-01-01
Limited data are available to assess the safety of high levels of hydrogen peroxide in overnight tooth-whitening formulas. The purpose of this study was to assess the effects of hydrogen peroxide on enamel microhardness, pulp penetration, and enamel morphology. Colgate Platinum Professional Overnight Whitening System (Colgate Oral Pharmaceuticals, Inc., Canton, MA, USA) (10% carbamide peroxide, equivalent to 3.5% hydrogen peroxide) was compared with two prototype formulations containing either 7.0% or 12.0% hydrogen peroxide. In the pulp chamber studies, human extracted teeth were exposed to 3.5%, 7.0%, or 12.0% hydrogen peroxide for 30 minutes, 4 hours, or 7 hours. Microhardness, electron spectroscopy for chemical analysis, and atomic force microscopy evaluations were made from enamel blocks cut from human extracted molars. The enamel blocks were evaluated following 14 7-hour treatments (98 h total). At 7 hours' post-treatment, hydrogen peroxide penetrated the pulp chamber at 23.12 +/- 10.09, 24.58 +/- 6.90, and 26.39 +/- 5.43 microg for 3.5%, 7.0%, and 12.0% hydrogen peroxide, respectively. With regard to enamel morphology, pulp penetration, microhardness, and elemental composition, no statistically significant differences were observed between treatment groups following 98 hours of treatment. Hydrogen peroxide does not adversely affect enamel morphology or microhardness. The levels recovered in pulp indicate that hydrogen peroxide is not expected to inhibit pulpal enzymes. Overnight tray products containing levels of hydrogen peroxide of 3.5%, 7.0%, and 12.0% are not expected to adversely affect the enamel or pulpal enzymes. Additional safety studies are needed to assess the potential for tooth sensitivity and gingival irritation.
Tooth Whitening: What We Now Know
Carey, Clifton M.
2014-01-01
Declarative Title Current research about tooth whitening shows that it is safe and effective when manufacturer’s protocol is followed, yet there are risks of which the profession and users should be aware. This update provides a summary of current research and assessment of the safety and efficacy of tooth whitening regimens. Background Tooth whitening has become one of the most frequently requested dental procedures by the public. The public has come to demand whiter, more perfect smiles and in response many choices for tooth whitening have been made available. These include home-based products such as toothpastes, gels, and films, as well as in-office based systems where products containing highly concentrated bleaching agents are applied under professional supervision. The profession and public have been aware of certain risks related to tooth whitening such as increased tooth sensitivity and gingival irritation. New research has shown that there are other risks such as tooth surface roughening and softening, increased potential for demineralization, degradation of dental restorations, and unacceptable color change of dental restorations. The new research is also focused on optimizing whitening procedures to reduce tooth sensitivity and to increase the persistence of the whitening. Methods Current reports in the literature are reviewed that are related to the use of peroxide based whitening methods. These reports include in vitro studies for method optimization and mechanism as well as clinical studies on effects of various whitening regimens. Conclusions When manufacturer’s instructions are followed, hydrogen peroxide and carbamide peroxide based tooth whitening is safe and effective. Patients should be informed of the risks associated with tooth whitening and instructed on identification of adverse occurrences so that they may seek professional help asneeded. PMID:24929591
Dionysopoulos, Dimitrios; Strakas, Dimitrios; Koliniotou-Koumpia, Eugenia
2015-08-01
The purpose of this in vitro study was to evaluate the influence of a novel in-office tooth whitening procedure using Er,Cr:YSGG laser radiation on bovine enamel. Forty-eight enamel specimens were prepared from bovine canines and divided into four groups: Group 1 specimens (control) received no whitening treatment; Group 2 received whitening treatment with an at-home whitening agent (22% carbamide peroxide) for 7 days; Group 3 received whitening treatment with a novel in-office whitening agent (35% H(2)O(2)); Group 4 received the same in-office whitening therapy with Group 3 using Er,Cr:YSGG laser in order to accelerate the whitening procedure. The specimens were stored for 10 days after the whitening treatment in artificial saliva. Vickers hardness was determined using a microhardness tester and surface roughness was evaluated using a VSI microscope. Three specimens of each experimental group were examined under SEM and the mineral composition of the specimens was evaluated using EDS. Data were statistically analyzed using one-way ANOVA, Tukey's post-hoc test, Wilcoxon signed rank and Kruskal-Wallis tests (a = 0.05). The surface microhardness of the enamel was reduced after the in-office whitening treatments (P< 0.05), but not influenced after the at-home whitening treatment (P> 0.05). Moreover, the surface roughness was not significantly changed after tooth whitening. EDS analysis did not show alterations in the enamel mineral composition, while SEM observations indicated changes in the surface morphology, especially after in-office tooth whitening (P< 0.05). The laser-assisted whitening treatment with Er,Cr:YSGG laser did not affect the alterations in enamel surface compared with the conventional in-office whitening technique. © 2015 Wiley Periodicals, Inc.
Briso, André Luiz Fraga; Rahal, Vanessa; Azevedo, Fernanda Almeida de; Gallinari, Marjorie de Oliveira; Gonçalves, Rafael Simões; Santos, Paulo Henrique Dos; Cintra, Luciano Tavares Angelo
2018-01-01
Objective The objective of this study was to evaluate dental sensitivity using visual analogue scale, a Computerized Visual Analogue Scale (CoVAS) and a neurosensory analyzer (TSA II) during at-home bleaching with 10% carbamide peroxide, with and without potassium oxalate. Materials and Methods Power Bleaching 10% containing potassium oxalate was used on one maxillary hemi-arch of the 25 volunteers, and Opalescence 10% was used on the opposite hemi-arch. Bleaching agents were used daily for 3 weeks. Analysis was performed before treatment, 24 hours later, 7, 14, and 21 days after the start of the treatment, and 7 days after its conclusion. The spontaneous tooth sensitivity was evaluated using the visual analogue scale and the sensitivity caused by a continuous 0°C stimulus was analyzed using CoVAS. The cold sensation threshold was also analyzed using the TSA II. The temperatures obtained were statistically analyzed using ANOVA and Tukey's test (α=5%). Results The data obtained with the other methods were also analyzed. 24 hours, 7 and 14 days before the beginning of the treatment, over 20% of the teeth presented spontaneous sensitivity, the normal condition was restored after the end of the treatment. Regarding the cold sensation temperatures, both products sensitized the teeth (p<0.05) and no differences were detected between the products in each period (p>0.05). In addition, when they were compared using CoVAS, Power Bleaching caused the highest levels of sensitivity in all study periods, with the exception of the 14th day of treatment. Conclusion We concluded that the bleaching treatment sensitized the teeth and the product with potassium oxalate was not able to modulate tooth sensitivity.
Briso, André Luiz Fraga; Rahal, Vanessa; de Azevedo, Fernanda Almeida; Gallinari, Marjorie de Oliveira; Gonçalves, Rafael Simões; dos Santos, Paulo Henrique; Cintra, Luciano Tavares Angelo
2018-01-01
Abstract Objective The objective of this study was to evaluate dental sensitivity using visual analogue scale, a Computerized Visual Analogue Scale (CoVAS) and a neurosensory analyzer (TSA II) during at-home bleaching with 10% carbamide peroxide, with and without potassium oxalate. Materials and Methods Power Bleaching 10% containing potassium oxalate was used on one maxillary hemi-arch of the 25 volunteers, and Opalescence 10% was used on the opposite hemi-arch. Bleaching agents were used daily for 3 weeks. Analysis was performed before treatment, 24 hours later, 7, 14, and 21 days after the start of the treatment, and 7 days after its conclusion. The spontaneous tooth sensitivity was evaluated using the visual analogue scale and the sensitivity caused by a continuous 0°C stimulus was analyzed using CoVAS. The cold sensation threshold was also analyzed using the TSA II. The temperatures obtained were statistically analyzed using ANOVA and Tukey's test (α=5%). Results The data obtained with the other methods were also analyzed. 24 hours, 7 and 14 days before the beginning of the treatment, over 20% of the teeth presented spontaneous sensitivity, the normal condition was restored after the end of the treatment. Regarding the cold sensation temperatures, both products sensitized the teeth (p<0.05) and no differences were detected between the products in each period (p>0.05). In addition, when they were compared using CoVAS, Power Bleaching caused the highest levels of sensitivity in all study periods, with the exception of the 14th day of treatment. Conclusion We concluded that the bleaching treatment sensitized the teeth and the product with potassium oxalate was not able to modulate tooth sensitivity. PMID:29742258
The Influence of Post Bleaching Treatments in Stain Absorption and Microhardness.
Moosavi, Horieh; Darvishzadeh, Fatemeh
2016-01-01
This study investigated the effects of post bleaching treatments to prevent restaining and the change of enamel surface microhardness after dental bleaching in vitro. Sixty intact human incisor teeth were stained in tea solution and randomly assigned into four groups (n=15). Then samples were bleached for two weeks (8 hours daily) by 15% carbamide peroxide. Tooth color was determined both with a spectrophotometer and visually before bleaching (T1) and immediately after bleaching (T2). Next, it was applied in group 1 fluoride (Naf 2%) gel for 2 minutes, and in group 2 a fractional CO2 laser (10 mJ, 200 Hz, 10 s), and in group 3, nanohydroxyapatite gel for 2 minutes. The bleached teeth in group 4 remained untreated (control group). Then teeth placed in tea solution again. Color examinations were repeated after various post bleaching treatments (T3) and restaining with tea (T4) and color change values recorded. The microhardness was measured at the enamel surface of samples. Data was analyzed using ANOVA, Tukey HSD test and Dunnett T3 (α = 0.05). Directly after bleaching (ΔE T3-T2), the treatment with nanohydroxyapatite showed significantly the least color lapse in colorimetric evaluation. In experimental groups, the color change between T3 and T4 stages (ΔE T4-T3) was significantly lower than control group (P < 0.05). Different methods of enamel treatment caused a significant increase in surface microhardness compared to control group (P < 0.05). Application of fluoride, fractional CO2 laser and nanohydroxyapatite as post bleaching treatments are suggested for prevention of stain absorption and increasing the hardening of bleached enamel.
Effect of bleaching agent extracts on murine macrophages.
Fernandes, Aletéia M M; Vilela, Polyana G F; Valera, Marcia C; Bolay, Carola; Hiller, Karl Anton; Schweikl, Helmut; Schmalz, Gottfried
2018-05-01
The aim of this study was to evaluate the cytotoxicity and the influence of bleaching agents on immunologically cell surface antigens of murine macrophages in vitro. RAW 264.7 cells were exposed to bleaching gel extracts (40% hydrogen peroxide or 20% carbamide peroxide) and different H 2 O 2 concentrations after 1 and 24-h exposure periods and 1-h exposure and 23-h recovery. Tests were performed with and without N-acetyl cysteine (NAC) and buthionine sulfoximine (BSO). Cell viability was determined by MTT assay. The expression of surface markers CD14, CD40, and CD54 with and without LPS stimulation was detected by flow cytometry, while the production of TNF-α was measured by ELISA. Statistical analysis was performed using the Mann-Whitney U test (α = 0.05). Extracts of bleaching agents were cytotoxic for cells after a 1-h exposure; cells could not recover after 24 h. This effect can be mitigated by the antioxidant NAC and increased by BSO, an inhibitor of glutathione (GSH) synthesis. LPS stimulated expression of all surface markers and TNF-α production. Exposure to bleaching agent extracts and H 2 O 2 leads to a reduction of TNF-α, CD14, and CD40 expression, while the expression of CD54 was upregulated at non-cytotoxic concentrations. Whereas NAC reduced this effect, it was increased in the presence of BSO. Extracts of bleaching agents were irreversibly cytotoxic to macrophages after a 1-h exposure. Only the expression of CD54 was upregulated. The reactions are mediated by the non-enzymatic antioxidant GSH. The addition of an antioxidant can downregulate unfavorable effects of dental bleaching.
Dentin bond strength and nanoleakage of the adhesive interface after intracoronal bleaching.
Cavalli, Vanessa; Sebold, Maicon; Shinohara, Mirela Sanae; Pereira, Patrícia Nóbrega Rodrigues; Giannini, Marcelo
2018-04-01
This study evaluated dentin bond strength (BS) and nanoleakage of non- and pre-etched dentin immediately (T 0 ,), 7 days (T 7 ), and 14 days (T 14 ) after bleaching. Bovine incisors (150) were selected and half of them submitted to intrapulpal dentin etching (e). Non- and pre-etched dentin were subjected to the following (n = 15): no bleaching/control (C); 35% carbamide peroxide (CP); 35% hydrogen peroxide (35% HP); 25% hydrogen peroxide (25% HP); and sodium perborate (SP). Bleaching agents were applied to the pulp chamber four times within a 72-h interval. Afterwards, pulp chamber dentin was prepared for the BS test at different evaluation times (n = 5): T 0 , T 7 , and T 14 . Composite blocks were built on pulp chamber and sectioned in slices. Slices were reduced to an hour-glass shape with a cross-sectional area of 0.8 mm 2 and submitted to microtensile BS test. Two additional specimens for each group were prepared for nanoleakage evaluation by transmission electron microscopy (TEM). Results were analyzed by ANOVA (two-way) and Dunnett's test (p < .05). BS decreased immediately after intracoronal bleaching for both sound and pre-etched dentin (p < .05). At T 14 , the BS of non-etched bleached dentin increased for all groups, whereas the pre-etched SPe group presented BS similar to the Ce. Nanoleakage within the hybrid layer was perceptible immediately after bleaching, although a decrease in nanoleakage was observed for all groups at T 14 . Adhesive restorations should be performed 7-14 days after bleaching, according to the bleaching agent used. Intracoronal bleaching should be performed preferably with sodium perborate if previous dentin etching is applied. © 2018 Wiley Periodicals, Inc.
Tang, Wei; Li, Zhezhe; Li, Chunhua; Yu, Xianhong; Wang, Fei; Wan, Xin; Wang, Yaping; Ma, Lixin
2016-06-01
Aminopeptidases are widely used for creating protein hydrolysates and peptide sequencing. The ywaD gene from a new Bacillus isolate, named Bacillus subtilis subsp. subtilis str. BSP1, was cloned into the yeast expression vector pHBM905A and expressed and secreted by Pichia pastoris strain GS115. The deduced amino acid sequence of the aminopeptidase encoded by the ywaD gene shared up to 98% identity with aminopeptidases from B. subtilis strains 168 and zj016. The yield (3.81 g/l) and specific activity (788 U/mg) of recombinant YwaD in high-density fermentation were extremely high. And 829.83 mg of the purified enzyme (4089.72 U/mg) were harvested. YwaD was glycosylated, and its activity decreased after deglycosylation, which was similar to that of the aminopeptidase from B. subtilis strain zj016. YwaD was most active toward l-arginine-4-nitroanilide. Moreover, it exhibited high resistance to carbamide, which was not true for aminopeptidases from B. subtilis strains 168 and zj016, which could simplify the purification of YwaD. Moreover, the expression and parts of characterization of the aminopeptidase from B. subtilis strain 168 in Pichia pastoris were added as supplementary material. The sequence and other characteristics of YwaD were compared with those of aminopeptidases from B. subtilis strains 168 and zj016, and they will provide a solid foundation for further research on the influence of amino acid mutations on the function of aminopeptidases. Copyright © 2016 Elsevier Inc. All rights reserved.
Torabi, Kianoosh; Rasaeipour, Sasan; Khaledi, Amir Alireza; Vojdani, Mahroo; Ghodsi, Safoura
2014-05-01
Pressing esthetic demands of good looking make people undergo bleaching procedures. However, the effect of bleaching agents on esthetic restorative materials with different surface preparations has been poorly studied. The aim of this study was to examine the effect of a homebleaching agent (carbamide peroxide: CP 38%) on the surface roughness of the polished fiber reinforced composite (FRC), overglazed, autoglazed, or polished ceramic samples. Twenty standardized cylindrical specimens were made of each of the following groups: over-glazed, autoglazed, polished porcelain and also FRC. The test specimens exposed to the CP 38%, 15 minutes, twice a day for 2 weeks according to the manufacturer's recommendation. Six samples from each group were selected randomly to form negative controls. Surface roughness measurements (Ra, micrometer) for baseline, test and control specimens were performed by use of a profilometer. Paired t-test, Mann-Whitney test, and Kruskal-Wallis test were used for statistical analyses. The data showed that bleaching with CP 38% significantly increased the surface roughness of all the test samples (p < 0.05). The type of surface preparation caused significant differences between the susceptibility of porcelain subgroups to bleaching (p < 0.05). The polished porcelain specimens showed the highest changes after bleaching. CP 38% significantly increases the surface roughness of the porcelains and FRC. The type of surface condition affects the amenability of the porcelain surface to the bleaching agent. Glazed porcelains were more resistant to roughness than the polished porcelains and also the composite. Roughening of porcelain and FRC occur following bleaching procedure. No special surface preparation of indirect esthetic restorative materials can completely preserve these materials from adverse effects of bleaching agents.
Cengiz, Esra; Kurtulmus-Yilmaz, Sevcan; Ulusoy, Nuran; Deniz, Sule Tugba; Yuksel-Devrim, Ece
2016-05-01
The aim of this study was to investigate the effect of hydrogen peroxide (HP) and carbamide peroxide (CP) on the surface roughness of five different composite resins using profilometer and scanning electron microscope (SEM). Thirty-six specimens (1 mm thick, 10 mm in diameter) of five composite resins were fabricated. Each composite group was equally divided into three subgroups as control, CP and HP. In control group, specimens were stored in daily refreshed distilled water during the 14-day testing period. In other groups, 10% HP (Opalescence Treswhite) and 10% CP (Opalescence PF) were applied and surface roughness values (Ra) of each specimen were measured with a profilometer at the end of 14 days. Additionally, SEM analysis was performed to evaluate the surface deformations of composite resins. Data were analyzed with Kruskal-Wallis and Mann-Whitney U tests. Ra values of composite groups exposed to bleaching agents were statistically higher than control group (p < 0.05). There was no significant difference between Ra values after HP and CP application within each composite group while SEM micrographs showed higher surface alterations at HP group compared to CP. Among the composite resins tested, Ceram-X Mono revealed the lowest Ra values after CP and HP applications as seen at SEM images. Home bleaching agents increased the surface roughness of all composites. Except CP applied Ceram-X mono specimens, Ra values of all composite resins evaluated in this study exceeded the critical limit of 0.2 μm. Ceram-X mono was the least affected composite material after bleaching application. SCANNING 38:277-283, 2016. © 2016 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.
Niat, Alireza Boruzi; Yazdi, Fatmeh Maleknejad; Koohestanian, Niloufar
2012-12-01
To determine the effect of drying agents and adhesive solvents on the bond strength of resin composite to enamel immediately after bleaching. Sixty healthy human premolars were bleached using 15% carbamide peroxide gel and randomly divided into three groups according to the immersing solutions applied immediately after bleaching: 70% alcohol, acetone, and distilled water. Each group was randomly divided into two subgroups according to the adhesives that were applied: an alcohol-based adhesive (Single Bond) and an acetone-based adhesive (One Step). By using rubber washers, composite Z100 was placed onto the enamel and shear bond strength was evaluated in a universal testing machine at a crosshead speed of 1 mm/min. The type of failure was also assessed using a stereomicroscope. The data were statistically analyzed by two-way ANOVA and Tukey's post-hoc test (α = 0.05). Fisher's Exact test was used to evaluate differences in the failure modes. Statistical analysis showed that the bond strength of the distilled water groups was significantly lower than that of the other groups, but the bond strengths of the two groups where a drying agent was applied were similar to that of the unbleached group. The acetone-based adhesive (One Step) provided higher bond strength than did the alcohol-based adhesive (Single Bond) (p < 0.05). There was no interaction between the two variables (p > 0.05). Fisher's Exact test showed there was no significant difference in the failure mode of all the experimental groups (p > 0.05). The application of drying agents improves the bond strength of resin composite to bleached enamel. Furthermore, the acetone-based adhesive used in the study had a higher bond strength to bleached enamel than did the alcohol-based adhesive used.
Kılınç, Halil İbrahim; Aslan, Tuğrul; Kılıç, Kerem; Er, Özgür; Kurt, Gökmen
2016-07-01
This study evaluated the effect of delayed bonding and antioxidant application (AA, 10% sodium ascorbate) after internal bleaching (35% carbamide peroxide) on the shear bond strength of an adhesive cement to enamel. Eighty-four human maxillary central incisors were endodontically treated. The control group remained unbleached with no AA. Experimental groups were all internally bleached. The buccal enamel was finished and polished with metallographic paper to a refinement of #600, in order to obtain a 5-mm(2) flat bonding area. An adhesive cement (Clearfil Esthetic) was placed into a plastic tube with internal diameter of 3 mm and a 3-mm height and cured on the enamel. Bonding occurred either immediately after bleaching (group Im), a 7-day delay (group 7), or a 14-day delay (group 14), and half the specimens were treated with antioxidant application (groups Im-AA, 7-AA, and 14-AA). Shear bond strength testing was performed on a universal testing machine, and data were analyzed with ANOVA and Fisher test (5%). Delaying of bonding is a useful factor for enhancing shear bond strength (p < 0.05), whereas AA only enhanced shear bond strength after 7 days delayed bleaching (p < 0.05). The highest bond strength was noted in groups 7-AA (20.51 ± 4.5 MPa), 14 (19.82 ± 4.6), 14-AA (20.27 ± 4.4), and control (20.51 ± 5.1), which were not significantly different from each other. After internal bleaching, adhesive cementation to enamel is recommended only when delayed 14 days, or delayed 7 days with sodium ascorbate application. © 2015 by the American College of Prosthodontists.
Incidence of tooth sensitivity after home whitening treatment.
Jorgensen, Michael G; Carroll, William B
2002-08-01
A potential side effect of dentist-dispensed home tooth-whitening systems is tooth sensitivity. The authors conducted a randomized prospective double-blind study to determine the incidence of tooth sensitivity after home whitening treatment. Fifty adult subjects used a gel containing 15 percent carbamide peroxide and 0.11 percent fluoride ion; an additional 50 adult subjects used a placebo gel daily for four weeks. Each subject's plaque index score, gingival recession status, caries status, current dentifrice and smoking history were recorded at baseline. The researchers evaluated sensitivity weekly by interview for four weeks. Fifty-four percent of subjects in both test and control groups reported mild sensitivity; 10 percent of test subjects and 2 percent of control subjects reported moderate sensitivity; 4 percent of test subjects and no control subjects reported severe sensitivity. Sensitivity decreased with time; by the second week, no severe sensitivity was reported, and by the fourth week, no moderate sensitivity was reported. The authors found a statistically significant positive correlation between reported sensitivity and gingival recession. They found no statistically significant correlations between sensitivity and any of the other recorded parameters. Mild tooth sensitivity can be expected in approximately one-half of patients who undergo home whitening treatment using the gel studied. Approximately 10 percent of patients may experience moderate sensitivity, and 4 percent of patients may experience severe sensitivity for one to two weeks. Patients with gingival recession appear more likely to experience tooth sensitivity during home whitening treatment. Patients considering home whitening treatment should be advised that mild tooth sensitivity is a common side effect and that severe tooth sensitivity occasionally occurs. If gingival recession is present, the probability of tooth sensitivity increases, and tooth sensitivity tends to decrease as treatment progresses.
Basir, Mahshid Mohammadi; Rezvani, Mohammad Bagher; Chiniforush, Nasim; Moradi, Zohreh
2016-01-01
Tooth restoration immediately after bleaching is challenging due to the potential problems in achieving adequate bond strength. The aim of this study was to evaluate the effect of surface treatment with ER:YAG, ND:YAG, CO2 lasers and 10% sodium ascorbate solution on immediate microtensile bond strength of composite resin to recently bleached enamel. Ninety sound molar teeth were randomly divided into three main groups (n:30) : NB (without bleaching), HB (bleached with 38% carbamide peroxide) and OB (bleached with Heydent bleaching gel assisted by diode laser). Each group was divided into five subgroups (n:6) : Si (without surface treatment), Er (Er:YAG laser), CO2 (CO2 laser), Nd (Nd:YAG laser) and As (Immersion in 10% sodium ascorbate solution). The bonding system was then applied and composite build-ups were constructed. The teeth were sectioned by low speed saw to obtain enamel- resin sticks and submitted to microtensile bond testing. Statistical analyses were done using two- way ANOVA, Tukey and Tamhane tests. µTBS of bleached teeth irradiated with ND:YAG laser was not significantly different from NB-Nd group. Microtensile bond strength of OB-Er group was higher than NB-Er and HB-Er groups. The mean µTBS of HB-CO2 group was higher than NB-CO2 group; the average µTBS of HB-As and OB-As groups was also higher than NB-As group. Use of Nd:YAG, CO2 lasers and 10% sodium ascorbate solution could improve the bond strength in home-bleached specimens. Application of ND:YAG laser on nonbleached specimens and Er:YAG laser on office-bleached specimens led to the highest µTBS in comparison to other surface treatments in each main group.
A randomized CIE L*a*b* evaluation of external bleaching therapy effects on fluorotic enamel stains.
Knösel, Michael; Attin, Rengin; Becker, Klaus; Attin, Thomas
2008-05-01
To evaluate the effect of external bleaching on the color and luminosity of fluorotic stains and adjacent, normally mineralized enamel areas by means of CIE L*a*b* colorimetry. Eighteen adolescents with mild to moderate fluorotic stains were randomly assigned to either bleaching group A (n = 9) or control group B. Eligibility criteria were fluorotic stained maxillary incisors or canines and the informed consent of the participants and their guardians. Using a colorimeter, CIE L*a*b* values of maxillary incisors and canines were assessed at baseline (T1) in the center of the fluorotic stained area (F1) and at adjacent, normally mineralized enamel areas (F2). Then, external bleaching with Illumine office (30% hydrogen peroxide, Dentsply DeTrey) was performed for 60 minutes, followed by color reassessment (T2). After 14 days (T3), a 2-week home bleaching period with a daily bleaching time of 1 hour with Illumine home (15% carbamide peroxide, Dentsply DeTrey) was conducted with subsequent color determination (T4). After completion of bleaching therapy, 96.0% of all fluorotic areas (F1) and 100% of normal enamel areas (F2) showed a significant change within group A, compared to 29.4% in control group B. Comparing the collective DeltaE (L*, a*, b*) of F1 and F2, 60.0% of all areas showed significant differences after completion of bleaching therapy, compared to 88.0% initially. Of group B sites, 82.4% showed color differences in the beginning (T1) and 88.2% at the end (T4). Whereas a single 1-hour session of in-office bleaching with 30% hydrogen peroxide does not significantly affect the color and luminosity of fluorotic teeth, a 14-day period of home bleaching leads to an assimilation of the color of the fluorotic stain with the color of surrounding enamel areas due to different responses of sound and fluorotic enamel to the bleaching regime.
dos SANTOS, Luciane Geanini Pena; FELIPPE, Wilson Tadeu; de SOUZA, Beatriz Dulcineia Mendes; KONRATH, Andrea Cristina; CORDEIRO, Mabel Mariela Rodríguez; FELIPPE, Mara Cristina Santos
2017-01-01
Abstract Regenerative endodontic procedure (REP) has been proposed as a new approach to treat immature permanent teeth. However, materials used in REP for root canal disinfection or cervical sealing may induce tooth discoloration. Objectives To assess tooth crown’s color after intracanal treatment with triple antibiotic paste (TAP) or calcium hydroxide (CH); cervical sealing with glass ionomer cement (GIC) or mineral trioxide aggregate (MTA); and bleaching with carbamide peroxide. Material and Methods After pulp removal and color spectrophotometer measurement, 50 bovine incisors were divided into 4 experimental groups and one control (untreated). Experiments were performed in phases (Ph). Ph1: TAP (ciprofloxacin, metronidazole, minocycline), TAPM (ciprofloxacin, metronidazole, amoxicillin), DAP (ciprofloxacin, metronidazole), or CH treatment groups. After 1 and 3 days (d); 1, 2, 3 weeks (w); and 1, 2, 3 and 4 months (m), color was measured and medications were removed. Ph2: GIC or MTA cervical sealing, each using half of the specimens from each group. Color was assessed after 1d, 3d; 1w, 2w, 3w; 1m and 2m. Ph3: Two bleaching sessions, each followed by color measurement. Data were analyzed with ANOVA and post-hoc Holm-Sidak method. Results Ph1: Specimens of TAP group presented higher color alteration (ΔE) mean than those of TAPM group. No significant difference was found among TAP or TAPM and CH, DAP or Control groups. Ph2: cervical sealing materials showed no influence on color alteration. Ph3: Different ΔE means (from different groups), prior to bleaching, became equivalent after one bleaching session. Conclusions TAP induces higher color alteration than TAPM; color alteration increases over time; cervical sealing material has no influence on color alteration; and, dental bleaching was able to recover, at least partially, the tooth crown’s color. PMID:28403365
Effects of different preparation procedures during tooth whitening on enamel bonding.
Wilson, Dustin; Xu, Changqi; Hong, Liang; Wang, Yong
2009-04-01
The objective of this study was to assess effects of some clinically related preparation procedures during tooth whitening on enamel bonding properties. Sixty-two extracted human teeth were cleaned and divided into four groups. Forty-two of the teeth were left with their natural surface intact while 20 teeth were polished to form a flat surface. Half of the tooth served as the experimental side and received one of the two whitening products: Opalescence (10% carbamide peroxide) and Crest Whitestrips (6.5% hydrogen peroxide), for 2 weeks. Post-bleaching intervals included: 1 day, 1 week, and 2 weeks. On these days, tooth (10 mm x 1.5 mm x 1.5 mm) sections were evaluated using Raman spectroscopy, scanning electron microscopy and tensile bond strength tests. T-test, ANOVA test, and mixed model regression analysis were used to assess the differences. No significant difference existed between natural surface and polished surface teeth for all groups at both Day One and Week Two (P > 0.05). On Day One, both treated groups had significant lower bond strength than the control group (P = 0.002). After 2 weeks, no significant difference existed between any group (P = 0.381). SEM indicated that resin-enamel interfaces in bleached enamel exhibited more defects in granular formations when compared to the control. Raman results indicated a lower degree of polymerization (DP) of adhesive at the interface for treated teeth surfaces. In summary, pre-bleaching surface treatments such as polish or non-polish, had no effect on bond strength. Bleaching significantly decreased bond strength initially, but after 2 weeks, bleaching had no significant effect on bond strength. Storage time had significant effect on Opalescence treated enamel, but not on control and Whitestrip treated enamel. The decrease of bond strength may be related to interfacial defects and low DP due to oxygen release after bleaching.
Effects of bleaching agents on human enamel light reflectance.
Markovic, Ljubisa; Fotouhi, Kasra; Lorenz, Heribert; Jordan, Rainer A; Gaengler, Peter; Zimmer, Stefan
2010-01-01
Tooth whitening has been associated with splitting-up chromogenic molecules by hydrogen peroxides. Though micromorphological alterations are well documented, little is known about optical changes as a function of shifting in wavelengths. Therefore, the aim of the current study was to measure reflectance changes after bleaching in vitro by using a spectrometer. Forty-eight enamel slabs (diameter = 5 mm) were prepared from the sound enamel of extracted human teeth that were: 1) fully impacted, 2) from juveniles ages 10 to 16 years, 3) from adults 35 to 45 years of age and 4) from seniors older than age 65. In all specimens, the baseline total reflectance measurement was performed with a computer-assisted spectrometer (Ocean Optics, Dunedin, FL, USA) within wavelengths (wl) from 430 nm to 800 nm. Four enamel samples of each age group were exposed to either 10% or 15% carbamide peroxide (Illuminé Home, Dentsply, Konstanz, Germany) or 35% hydrogen peroxide (Pola Office, SDI Limited, Victoria, Australia). After surface treatment, all slabs underwent total reflectance measurement again. Statistical analysis was calculated at wl 450, 500 and 750 nm using the Student's paired t-test and one-way variance analysis. Total reflectance significantly increased after bleaching at all enamel maturation stages, irrespective of the bleaching agent concentration, for wl 450 nm (blue) and 500 nm (green) with p<0.0001. At 750 nm (red), significant changes only occurred in enamel from adults and seniors (p<0.04). However, the efficacy of bleaching was significantly increased in the blue and green light spectra as compared to the red spectra (p<0.0001). The results of the current study showed that the exclusive assumption of the "chromophore effect" in dental bleaching could not be sustained, because whitening of the dental enamel works at different maturation stages, even in impacted teeth. This effect is irrespective of the bleaching protocol used and the bleaching agent concentration.
Spectrophotometric evaluation of dental bleaching under orthodontic bracket in enamel and dentin
Correr, Americo-Bortolazzo; Rastelli, Alessandra-Nara-Souza; Lima, Débora-Alves-Nunes-Leite; Consani, Rafael-Leonardo-Xediek
2014-01-01
Aware of the diffusion capacity of bleaching in the dental tissues, many orthodontists are subjecting their patients to dental bleaching during orthodontic treatment for esthetic purposes or to anticipate the exchange of esthetic restorations after the orthodontic treatment. For this purpose specific products have been developed in pre-loaded whitening trays designed to fit over and around brackets and wires, with clinical efficacy proven. Objective: The objective of this study was to evaluate, through spectrophotometric reflectance, the effectiveness of dental bleaching under orthodontic bracket. Material and Methods: Thirty-two bovine incisors crown blocks of 8 mm x 8 mm height lengths were used. Staining of tooth blocks with black tea was performed for six days. They were distributed randomly into 4 groups (1-home bleaching with bracket, 2- home bleaching without bracket, 3- office bleaching with bracket, 4 office bleaching without bracket). The color evaluation was performed (CIE L * a * b *) using color reflectance spectrophotometer. Metal brackets were bonded in groups 1 and 3. The groups 1 and 2 samples were subjected to the carbamide peroxide at 15%, 4 hours daily for 21 days. Groups 3 and 4 were subjected to 3 in-office bleaching treatment sessions, hydrogen peroxide 38%. After removal of the brackets, the second color evaluation was performed in tooth block, difference between the area under the bracket and around it, and after 7 days to verified color stability. Data analysis was performed using the paired t-test and two-way variance analysis and Tukey’s. Results: The home bleaching technique proved to be more effective compared to the office bleaching. There was a significant difference between the margin and center color values of the specimens that were subjected to bracket bonding. Conclusions: The bracket bond presence affected the effectiveness of both the home and office bleaching treatments. Key words:Tooth bleaching, spectrophotometry, orthodontics. PMID:25593650
Moghadam, Fatemeh Velayati; Majidinia, Sara; Chasteen, Joseph; Ghavamnasiri, Marjaneh
2013-01-01
Aim: The purpose of the present randomized clinical trial was to evaluate the color change, rebound effect and sensitivity of at-home bleaching with 15% carbamide peroxide and power bleaching using 38% hydrogen peroxide. Materials and Methods: For bleaching techniques, 20 subjects were randomized in a split mouth design (at-home and power bleaching): In maxillary and mandibular anterior teeth (n = 20). Color was recorded before bleaching, immediately after bleaching, at 2 weeks, 1, 3 and 6 month intervals. Tooth sensitivity was recorded using the visual analog scale. The Mann-Whitney test was used to compare both groups regarding bleaching effectiveness (ΔE1), rebound effect (ΔE2) and color difference between the rebounded tooth color and unbleached teeth (ΔE3) while the Wilcoxon compared ΔE within each group. Distribution of sensitivity was evaluated using the Chi-square test (α =0.05). Results: There was no significant difference between groups regarding ΔE1 and ΔE3 (P > 0.05). Even though, ΔE2 showed no significant difference between groups after bleaching as well as at 2 week, 1 month and 3 month follow-up periods (P > 0.05). Although, significant difference was found in ΔE2 (P < 0.05 Mann-Whitney) between two methods after 6 months and a high degree of rebound effect was obtained with power bleaching. Within each group, there was no significant difference between ΔE1 and ΔE3 (P < 0.05 Wilcoxon). The distribution of sensitivity was identical with both techniques (P > 0.05). Conclusion: Bleaching techniques resulted in identical tooth whitening and post-operative sensitivity using both techniques, but faster color regression was found with power bleaching even though color regression to the baseline of the teeth in both groups was the same after 6 months. PMID:24932113
The effect of long-term use of tooth bleaching products on the human enamel surface.
Polydorou, Olga; Scheitza, Sophia; Spraul, Mathias; Vach, Kirstin; Hellwig, Elmar
2018-01-01
The aim of this in vitro study was to evaluate the long-term effect of bleaching on human enamel. Four groups of enamel specimens were prepared (n = 20): group 1: bleaching with Opalescence Boost [40% hydrogen peroxide (H 2 O 2 ), 3 × 20 min/week]; group 2: control group (the specimens were stored in human saliva); group 3: beaching with Vivastyle Paint on Plus (6% H 2 O 2 , 2 × 10 min/day), and group 4: bleaching with Opalescence PF 16% [16% carbamide peroxide (CP), 6 h/day]. After each bleaching session the specimens were stored in human saliva. Knoop microhardness and surface roughness were measured: before bleaching, after 2-week and after 8-week bleaching. After 2-week treatment, surface roughness was significantly increased in all experimental groups (p < 0.05), while among them no significant difference was found (p > 0.05). The roughness changes exerted after 8-week bleaching were not significantly higher than the ones after 2 weeks (p > 0.05). After 8-week treatment, the increase in roughness caused by 16% CP was significantly higher (p < 0.05) than the one caused by 40% H 2 O 2 . Microhardness increased in all groups including control; however, only 40% H 2 O 2 increased the microhardness significantly (p < 0.05). The effect of bleaching on enamel was not shown to be dependent on the method or the H 2 O 2 concentration. Bleaching with CP 16% resulted in higher roughness than bleaching with H 2 O 2 , while 40% H 2 O 2 caused the higher microhardness increase. The present study showed that in-office bleaching with 40% H 2 O 2 seems to be at least as safe as home bleaching as far as their effects on human enamel are concerned.
Iska, Divya; Devanna, Raghu; Singh, Madhvi; Chitumalla, Rajkiran; Balasubramanian, Sai C Bala; Goutam, Manish
2017-12-01
Esthetics is one of the common issues because of which patients consult dental orthodontic treatment. Two ways of tooth bleaching are available these days, which includes in-office bleach and home bleach. Various bleaching protocols are available these days for treating the tooth surfaces. Hence, we planned the present study for investigating the impact of various intracoronal bleaching protocols on shear bond strength of ceramic brackets bonded to tooth surface after bleaching. The present study included assessment of 100 extracted maxillary central incisors with the integrated buccal surface. A resin block was made and individual teeth were embedded in each block. Root canal therapy procedure was performed in all the teeth, after which 2 mm short of tooth apex up to the level of cementoenamel junction, removal of the root canal filling was done. All the samples were broadly divided into four study groups with 25 samples in each group. Bleaching procedure was carried in all the samples intracoronally followed by testing of shear bond strength using universal force testing machine. Following the modified adhesive remnant index (AI), assessment of remaining adhesive on the brackets was done. All the results were compiled and analyzed by Statistical Package for the Social Sciences (SPSS) software version 17.0. In the control group, mean shear bond strength was found to be 17.9 MPa. While comparing the carbamide peroxide (CP) group with sodium perborate study group, we observed a statistically significant difference. Nonsignificant results were obtained while comparing the shear bond strength in between sodium perborate group and hydrogen peroxide (HP) group. Intracoronal bleaching does affect the shear bond strength of ceramic brackets. Sodium perborate bleaching influences shear bond strength more strongly than other bleaching agents such as CP and HP. In patients undergoing orthodontic treatment, HP is a preferred agent where bleaching has to be followed by orthodontic bonding to the tooth surface.
Yu, Dandan; Gao, Shanshan; Min, Jie; Zhang, Qianqian; Gao, Shuai; Yu, Haiyang
2015-12-01
Teeth bleaching cases had increased with people's desire for oral aesthetic; however, bleached teeth would still undertake chewing actions and remineralizing process in saliva. Nanotribological and nanomechanical properties are proper displays for dental performance of bleached teeth. The purpose of the research was to reveal the effect of bleaching and remineralization on the nanotribological and nanomechanical properties of teeth in wet environment. The specimens were divided into four groups according to the bleaching products used: 12 % hydrogen peroxide (HP) (12HP group); 15 % carbamide peroxide (CP) (15CP group); 35 % CP (35CP group); and artificial saliva (control group). The nanotribological and nanomechanical property changes of tooth enamel after bleaching and remineralization were evaluated respectively by nanoscratch and nanoindentation tests in wet environment, imitating the wet oral environment. The morphology changes were evaluated by statistical parametric mapping (SPM) and scanning electron microscopy (SEM). After bleaching, 12HP group and 15CP group showed increased scratch depth with more pile ups on the scratch edges, decreased nanohardness, and corroded surface appearance. While the 35CP group showed an increase in nanoscratch depth, no change in nanohardness and surface appearance was observed. The control group showed no change in these measurements. After remineralization, the three bleaching groups showed decreased nanoscratch depth and no change of nanohardness compared with the bleached teeth. And the control group showed no changes in nanotribological and nanomechanical properties. The nanotribological and nanomechanical properties of the 12HP group and 15CP group were affected by bleaching, but the nanotribological properties recovered partly and the nanomechanical properties got no change after 1 week of remineralization. As for the 35CP group, the nanotribological properties were influenced and the nanomechanical properties were not affected. These results remind us of taking actions to protect our teeth during bleaching.
Nightguard vital bleaching: side effects and patient satisfaction 10 to 17 years post-treatment.
Boushell, Lee W; Ritter, André V; Garland, Glenn E; Tiwana, Karen K; Smith, Lynn R; Broome, Angela; Leonard, Ralph H
2012-06-01
The long-term patient satisfaction and safety of nightguard vital bleaching (NGVB) requires further evaluation. The purpose of this study was to evaluate patients' satisfaction and identify side effects of NGVB up to 17 years post-treatment. Thirty-one participants who had completed previous NGVB studies using 10% carbamide peroxide were contacted at least 10 years post-treatment (range 10-17 years, average 12.3 years). Participants reported shade satisfaction (very satisfied [VS], partially satisfied [PS], or not satisfied [NS]) as well as potential complications. Participants had teeth # 6 to 11 examined for tooth vitality, gingival inflammation (Löe's Gingival Index [GI]), and radiographically for external cervical resorption (ECR). All of the participants had successful lightening of their teeth. Sixty-one percent (19) had not retreated their teeth. Of those who had not retreated their teeth and who responded to the question of whitening satisfaction, 31% (4/13) were VS, 54% (7/13) were PS, and 15% (2/13) were NS with their current shade. Of those who had retreated their teeth, all were VS or PS. Ninety-one percent of the examined teeth had GI = 0 (normal), 7% had GI = 1 (mild inflammation), and 2% had GI = 2 (moderate inflammation). Sixty-nine percent of teeth tested responded to a cold stimulus. Radiographs did not detect ECR or apical lesions. No participant reported having a gingival biopsy post-treatment, and 87% would whiten again. Patient satisfaction with NGVB may last as long as 12.3 years in average (range 10-17 years) post-treatment. GI and ECR findings were considered within the normal expectations for the sample studied, suggesting minimal clinical post-NGVB side effects up to 17 years. Nightguard vital bleaching provides patient satisfaction with minimal side effects up to 17 years post-treatment. © 2011 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Yu, Dandan; Gao, Shanshan; Min, Jie; Zhang, Qianqian; Gao, Shuai; Yu, Haiyang
2015-12-01
Teeth bleaching cases had increased with people's desire for oral aesthetic; however, bleached teeth would still undertake chewing actions and remineralizing process in saliva. Nanotribological and nanomechanical properties are proper displays for dental performance of bleached teeth. The purpose of the research was to reveal the effect of bleaching and remineralization on the nanotribological and nanomechanical properties of teeth in wet environment. The specimens were divided into four groups according to the bleaching products used: 12 % hydrogen peroxide (HP) (12HP group); 15 % carbamide peroxide (CP) (15CP group); 35 % CP (35CP group); and artificial saliva (control group). The nanotribological and nanomechanical property changes of tooth enamel after bleaching and remineralization were evaluated respectively by nanoscratch and nanoindentation tests in wet environment, imitating the wet oral environment. The morphology changes were evaluated by statistical parametric mapping (SPM) and scanning electron microscopy (SEM). After bleaching, 12HP group and 15CP group showed increased scratch depth with more pile ups on the scratch edges, decreased nanohardness, and corroded surface appearance. While the 35CP group showed an increase in nanoscratch depth, no change in nanohardness and surface appearance was observed. The control group showed no change in these measurements. After remineralization, the three bleaching groups showed decreased nanoscratch depth and no change of nanohardness compared with the bleached teeth. And the control group showed no changes in nanotribological and nanomechanical properties. The nanotribological and nanomechanical properties of the 12HP group and 15CP group were affected by bleaching, but the nanotribological properties recovered partly and the nanomechanical properties got no change after 1 week of remineralization. As for the 35CP group, the nanotribological properties were influenced and the nanomechanical properties were not affected. These results remind us of taking actions to protect our teeth during bleaching.
Explosives detection using photoneutrons produced by X-rays
NASA Astrophysics Data System (ADS)
Yang, Yigang; Li, Yuanjing; Wang, Haidong; Li, Tiezhu; Wu, Bin
2007-08-01
The detection of explosives has become a critical issue after recent terrorist attacks. This paper describes research on explosives detection using photoneutrons from a photoneutron convertor that consists of 20 kg heavy water in an aluminum container whose shape was optimized to most effectively convert X-rays to photoneutrons. The X-rays were produced by a 9 MeV electron accelerator with an average electron current of 100 μA, resulted in a photoneutron yield of >10 11 n/s. Monte-Carlo simulations show that the radiation field is composed of X-ray pulses, fast neutron pulses and thermal neutrons. Both the X-ray and fast neutron pulses are 5 μs wide with a 300 Hz repetition frequency. The thermal neutron flux, which is higher than 10 4 n/cm 2/s, is essentially time invariant. A time shielding circuit was developed for the spectrometry system to halt the sampling process during the intense X-ray pulses. Paraffin, boron carbide and lead were used to protect the detector from interference from the X-rays, fast neutrons, thermal neutrons and background γ-rays coming from the system materials induced by photoneutrons. 5″×5″ NaI (Tl) scintillators were chosen as the detectors to detect the photoneutrons induced γ-rays from the inspected explosive simulant. Nitrogen (6.01 cps) 10.828 MeV γ-rays were detected with one detector from a 50 kg carbamide block placed 60 cm in front of the detector. A collimator was used to reduce the number of background 10.828 MeV γ-rays coming from the nitrogen in the air to improve the signal to background ratio from 0.136 to 1.81. A detector array of seven 5″×5″ NaI (Tl) detectors was used to measure the 2-D distributions of N and H in the sample. The combination of photoneutron analysis and X-ray imaging shows promise for enhancing explosives detection capabilities.
Salomão, Dlf; Santos, Dm; Nogueira, Rd; Palma-Dibb, Rg; Geraldo-Martins, Vr
2014-01-01
The aim of the current study was to assess the acid demineralization susceptibility of bleached dental enamel submitted to different fluoride regimens. One hundred bovine enamel blocks (6×6×3 mm) were randomly divided into 10 groups (n=10). Groups 1 and 2 received no bleaching. Groups 3 to 6 were submitted to an at-home bleaching technique using 6% hydrogen peroxide (HP; G3 and G4) or 10% carbamide peroxide (CP; G5 and G6). Groups 7 to 10 were submitted to an in-office bleaching technique using 35% HP (G7 and G8) or 35% CP (G9 and G10). During bleaching, a daily fluoridation regimen of 0.05% sodium fluoride (NaF) solution was performed on groups 3, 5, 7, and 9, while weekly fluoridation with a 2% NaF gel was performed on groups 4, 6, 8, and 10. The samples in groups 2 to 10 were pH cycled for 14 consecutive days. The samples from all groups were then assessed by cross-sectional Knoop microhardness at different depths from the outer enamel surface. The average Knoop hardness numbers (KHNs) were compared using one-way analysis of variance and Tukey tests (α=0.05). The comparison between groups 1 and 2 showed that the demineralization method was effective. The comparison among groups 2 to 6 showed the same susceptibility to acid demineralization, regardless of the fluoridation method used. However, the samples from groups 8 and 10 showed more susceptibility to acid demineralization when compared with group 2 (p<0.05). Groups 7 and 9 provided similar results to group 2, but the results of those groups were different when compared with groups 8 and 10. The use of 6% HP and 10% CP associated with daily or weekly fluoridation regimens did not increase the susceptibility of enamel to acid demineralization. However, the use of 35% HP and 35% CP must be associated with a daily fluoridation regimen, otherwise the in-office bleaching makes the bleached enamel more susceptible to acid demineralization.
Carlos, N R; Bridi, E C; Amaral, Flb; França, Fmg; Turssi, C P; Basting, R T
The purpose of this study was to evaluate bleaching methods containing hydrogen peroxide (HP) or carbamide peroxide (CP), dispensed in customized or prefilled trays, in terms of color change, tooth sensitivity, gingival irritation, acceptance, and comfort. Seventy-five volunteers were randomly selected and distributed according to the whitening agent (n=25): 10% HP dispensed in prefilled trays (Opalescence Go 10%) and 9.5% HP (Pola Day) and 10% CP both delivered in customized trays (Opalescence PF 10%). HP was applied for 30 min/d for 14 days (d), and CP for 8 h/d for 14 days. Evaluations were performed at baseline and at 7 days and 14 days of treatment. Color change was measured with Commission internationale de l'éclairage color coordinates (L*, a*, b*), Vita Classical, and 3D Master scales. A visual analog scale was used to assess tooth sensitivity, acceptance of the method and degree of comfort of the tray. Gingival irritation was evaluated as present or absent and localized or generalized. Regarding gingival irritation, tray acceptance, and tooth sensitivity, no differences were observed among the groups at any time (p>0.05). As for degree of comfort, 10% HP showed lower scores (comfortable) than 10% CP, with significant differences (p<0.05) from the other groups (comfortable to very comfortable). In terms of ΔL, Δa, and ΔE, no difference was observed among the groups or between the time periods (p>0.05). The Δb average was higher at 14 days (p<0.05), and there was no difference among the groups (p>0.05). Localized gingival irritation was observed in both tray methods. Mild tooth sensitivity was observed with time, regardless of the bleaching agent concentration or the application time. Color change was similar for all the groups at 7 days and 14 days, but there was a greater reduction in the yellow hue at 14 days. All the bleaching methods were highly accepted and effective in promoting whitening. Although prefilled trays are generally comfortable, they proved less comfortable than customized trays.
Effect of two different bleaching regimens on the gloss of tooth colored restorative materials.
Yalcin, Filiz; Gürgan, Sevil
2005-05-01
Vital tooth bleaching with peroxide is one of the most common cosmetic procedures in dentistry and can be accomplished using a variety of methods or regimens. Recently, new generation of tooth color restorative materials were introduced to market. The purpose of this in vitro study was to determine the gloss changes of three different tooth color restorative materials: Flowable composite (Filtek Flow/3M), packable composite (Filtek P60/3M) and ormocer (Definite/DEGUSSA) after two different bleaching regimens (Vivastyle/VIVADENT) and (Crest Professional Whitestrips/PROCTER and GAMBLE). 16 specimens 30 x 30 x 2 mm size were fabricated from each restorative material. After gloss values were measured with gloss meter, at two different angles of illumination (20 and 60 degrees ), 10% carbamide peroxide (Vivastyle) was applied for 2 h per day for fourteen days to the half of the specimens while 6.5% hydrogen peroxide strip bands (Crest Professional Whitestrips) were applied to the remaining eight of the specimens for 30 min twice daily for 14 days. During the test period the specimens were stored in 37 degrees C and 100% relative humidity. At the end of bleaching regimen the gloss measurements were repeated and the data were subjected to statistical analysis. The Wilcoxon Signed Rank Test analysis revealed that the gloss values were affected by both bleaching regimens (P=0.012). Whitestrips decreased the gloss values of Filtek P60 (at 20 and 60 degrees , P<0.001) and Filtek Flow (at 20 degrees , P=0.05 and at 60 degrees , P=0.05) significantly compared to Vivastyle, while the gloss values of Definite did not show any significant change between Vivastyle and Whitestrips application (at 20 degrees P=0.279; at 60 degrees , P=0.279, Mann-Whitney U Test). The gloss values of materials were significantly different before (at 20 degrees P<0.001; at 60 degrees , P=0.003) and after bleaching (at 20 degrees P<0.05; at 60 degrees , P<0.05) with the highest value of Filtek Flow followed Filtek P60 and then by Definite (Kruskal Wallis test). As the gloss of tooth colored restorative materials could be affected by bleaching regimens, it is necessary to consider the type of the material before starting the treatment.
Electrochemical corrosion and surface analyses of a ni-cr alloy in bleaching agents.
Tamam, Evşen; Aydın, A Kevser; Bilgiç, Semra
2014-10-01
The aim of this study was to evaluate the corrosion behavior of a Ni-Cr dental casting alloy subjected to 10% hydrogen peroxide (HP) and 10% carbamide peroxide (CP) bleaching solutions and to determine the composition of the surface oxide layer formed on the alloy specimens. Ten cylindrical specimens (4 mm in diameter × 25 mm in height) were cast from a Ni-Cr alloy (Wiron 99) and divided into two groups (n = 5). A potentiodynamic polarization test was used to compare the corrosion rates of specimens in HP and CP (pH = 6.5). Before cyclic polarization tests, all alloy specimens were allowed to reach a steady open circuit potential (Ecorr ) for a period of 1 hour. Then tests were initiated at 100 mV versus standard calomel electrode (SCE) below Ecorr and scanned at a rate of 1 mV/s in the anodic direction until reaching 1000 mV over the Ecorr value. The scan then was reversed back to the Ecorr of the specimens. The open circuit potentials (Ecorr ) and the current densities (Icorr ) were determined using the anodic Tafel regions extrapolating from the curves. Differences in Ecorr and Icorr were determined using one-way ANOVA (α = 0.05). In addition, corrosion rates were calculated from these curves. Before and after polarization tests, a scanning electron microscope (SEM) examination accompanied by energy dispersive X-ray spectroscopy (EDS) was used to analyze the surface morphology. The surface characterization of the passive film formed on alloy specimens was also performed by using X-ray photoelectron spectroscopy (XPS). In this study, bleaching agents had an effect on the anodic process for two groups. Although no statistical difference was identified between the groups for both corrosion parameters, results indicated that the effect of CP on the corrosion behavior was less than that of HP. These results agreed with the SEM observations. XPS data showed that oxide layers formed on all groups contained mainly Cr2 O3 , NiO, and MoO3 , and the amounts of oxides formed on CP-treated specimens were higher than HP treated ones. Also, molybdenum rates were increased with CP application compared to HP. The comparison of the effects of the two bleaching agents at 10% showed that the alloy suffered less corrosion with CP than HP. This result was also confirmed by the SEM and XPS data. The presence of Mo on the oxide layer affected the oxide layer, leading to lower corrosion rates. © 2014 by the American College of Prosthodontists.
Techno-economic analysis for the evaluation of three UCG synthesis gas end use approaches
NASA Astrophysics Data System (ADS)
Nakaten, Natalie; Kempka, Thomas; Burchart-Korol, Dorota; Krawczyk, Piotr; Kapusta, Krzysztof; Stańczyk, Krzysztof
2016-04-01
Underground coal gasification (UCG) enables the utilization of coal reserves that are economically not exploitable because of complex geological boundary conditions. In the present study we investigate UCG as a potential economic approach for conversion of deep-seated coals into a synthesis gas and its application within three different utilization options. Related to geological boundary conditions and the chosen gasification agent, UCG synthesis gas composes of varying methane, hydrogen, nitrogen, carbon monoxide and carbon dioxide amounts. In accordance to its calorific value, the processed UCG synthesis gas can be utilized in different manners, as for electricity generation in a combined cycle power plant or for feedstock production making use of its various chemical components. In the present study we analyze UCG synthesis gas utilization economics in the context of clean electricity generation with an integrated carbon capture and storage process (CCS) as well as synthetic fuel and fertilizer production (Kempka et al., 2010) based on a gas composition achieved during an in situ UCG trial in the Wieczorek Mine. Hereby, we also consider chemical feedstock production in order to mitigate CO2 emissions. Within a sensitivity analysis of UCG synthesis gas calorific value variations, we produce a range of capital and operational expenditure bandwidths that allow for an economic assessment of different synthesis gas end use approaches. To carry out the integrated techno-economic assessment of the coupled systems and the sensitivity analysis, we adapted the techno-economic UCG-CCS model developed by Nakaten et al. (2014). Our techno-economic modeling results demonstrate that the calorific value has a high impact on the economics of UCG synthesis gas utilization. In the underlying study, the synthesis gas is not suitable for an economic competitive electricity generation, due to the relatively low calorific value of 4.5 MJ/Nm³. To be a profitable option for electricity production, the UCG synthesis gas should have a calorific value of at least 7 MJ/Nm³. However, UCG feedstock production in view of the underlying geological and chemical boundary conditions can compete on the market. Kempka, T., Plötz, M.L., Hamann, J., Deowan, S.A., Azzam, R. (2010) Carbon dioxide utilisation for carbamide production by application of the coupled UCG-urea process. Energy Procedia 4: 2200-2205. Nakaten, N., Schlüter, R., Azzam, R., Kempka, T. (2014) Development of a techno-economic model for dynamic calculation of COE, energy demand and CO2 emissions of an integrated UCG-CCS process. Energy (in print). Doi 10.1016/j.energy.2014.01.014
Gurbuz, Ayhan; Ozkan, Pelin; Yilmaz, Kerem; Yilmaz, Burak; Durkan, Rukiye
2013-01-01
Oxygenating agents like carbamide peroxide or H(2) O(2) are commonly used whitening agents. They have varying influence on the color and surface roughness of resin-based restorative materials and teeth. The aim of this study was to evaluate the effect of an at-home peroxide whitening agent applied through a whitening strip on the color and surface roughness of a nanofilled composite resin and an ormocer-based resin. Disc-shaped (2 mm thick, 10 mm diameter) nanofilled resin composite (n = 10) and ormocer (n = 10) specimens were prepared. All specimens were treated with a whitening strip. Whitening procedures were performed applying a 6.5% hydrogen peroxide whitening strip (Crest White Strips Professional) for 30 minutes twice each day for a period of 21 consecutive days. During the test intervals, the specimens were rinsed under running distilled water for 1 minute to remove the whitening agents and immersed in 37°C distilled water until the next treatment. Surface roughness and color of the specimens were measured with a profilometer and a colorimeter, respectively, before and after whitening. Color changes were calculated (ΔE) using L*, a*, and b* coordinates. Repeated measures of variance analysis and Duncan test were used for statistical evaluation (α= 0.05). The average surface roughness of composite increased from 1.4 Ra to 2.0 Ra, and from 0.8 Ra to 0.9 Ra for the ormocer material; however, these changes in roughness after whitening were not significant (p > 0.05). Also, when two materials were compared, the surface roughness of restorative materials was not different before and after whitening (p > 0.05). L* and b* values for each material changed significantly after whitening (p < 0.05). ΔE values (before/after whitening) calculated for composite (11.9) and ormocer (16.1) were not significantly different from each other (p > 0.05). The tested whitening agent did not affect the surface roughness of either resin-based restorative material. Both materials became brighter after whitening. The behavior of the materials in the yellow/blue axis was opposite to each other after whitening. Each material had clinically unacceptable color change after whitening (ΔE > 5.5); however, the magnitude of the color change of materials was similar (p > 0.05). According to the results of this study, with the use of materials tested, patients should be advised that existing composite restorations may bleach along with the natural teeth, and replacement of these restorations after whitening may not be required. © 2012 by the American College of Prosthodontists.
NASA Astrophysics Data System (ADS)
Nakaten, Natalie; Kapusta, Krzysztof; Burchart-Korol, Dorota; Kempka, Thomas
2017-04-01
Underground coal gasification (UCG) enables the utilization of coal reserves that are economically not exploitable because of complex geological boundary conditions. In the present study, we investigate site-specific commercial-scale onshore and offshore UCG-systems combined with carbon capture and storage (CCS) in line with electricity, synthetic natural gas (SNG) and fertilizer (urea) production based on data of in-situ trail undertaken at the Wieczorek coal mine (Silesian Basin, Poland) [1] and ex-situ tests on different Polish coals. Hereby, techno-economic modeling approaches according to Kempka et al. [2] and Nakaten et al. [3] have been applied to determine onshore and offshore levelized end-use product costs as well as cost bandwidths resulting from economical, technical and geological uncertainties. Our analysis results show that the investigated onshore UCG end-use options are by 3 % (SNG), 27 % (electricity) and 47 % (urea) lower than the according market prices, and thus competitive on the Polish energy market. However, due to high costs for the offshore platform and the related infrastructure, offshore UCG end-use products are not economic in view of the EU raw materials and energy market. For UCG-CCS systems, a relevant approach to decrease production costs is a precise management of the oxidizer composition: an oxygen ratio below 30 % by volume and a high UCG-to-syngas conversion efficiency favor the economics of electricity and SNG production, whereby cost-effective urea production under the given boundary conditions is characterized by high CO2 and H2 ratios in the synthesis gas composition. As drilling costs have a limited share on total levelized production costs of 3 % in maximum, uncertainties related to model input parameters affected by drilling costs, e.g., UCG reactor width, are negligible. From our techno-economic modeling results, we conclude that competitiveness of the investigated onshore UCG-CCS end-use options will be even more profitable in view of the expected future development of natural gas prices. [1] Stanczyk, K., Howaniec, N., Smolinski, A., Swiadrowski, J., Kapusta, K., Wiatowski, M., Grabowski, J., Rogut, J. (2011): Gasification of lignite and hard coal with air and oxygen enriched air in a pilot scale ex-situ reactor for underground gasification. Fuel, 90, p. 1953-1962, doi:10.1016/j.fuel.2010.12.007. [2] Kempka, T., Schlüter, R., Hamann, J., Deowan, S., Azzam, R. (2011): Carbon dioxide utilisation for carbamide production by application of the coupled UCG-Urea process. Energy Procedia, 4, p. 2200-2205, doi.org/10.1016/j.egypro.2011.02.107. [3] Nakaten, N.C., Schlüter, R., Azzam, R. and Kempka, T. (2014): Development of a techno-economic model for dynamic calculation of COE, energy demand and CO2 emissions of an integrated UCG-CCS process. Energy, 66, p. 779-790, doi: 10.1016/j.energy.2014.01.014.
NASA Astrophysics Data System (ADS)
Nakaten, Natalie; Islam, Rafiqul; Kempka, Thomas
2014-05-01
The application of underground coal gasification (UCG) with proven carbon mitigation techniques may provide a carbon neutral approach to tackle electricity and fertilizer supply shortages in Bangladesh. UCG facilitates the utilization of deep-seated coal seams, not economically exploitable by conventional coal mining. The high-calorific synthesis gas produced by UCG can be used for e.g. electricity generation or as chemical raw material for hydrogen, methanol and fertilizer production. Kempka et al. (2010) carried out an integrated assessment of UCG operation, demonstrating that about 19 % of the CO2 produced during UCG may be mitigated by CO2 utilization in fertilizer production. In the present study, we investigated an extension of the UCG system by introducing excess CO2 storage in the gas deposit of the Bahkrabad gas field (40 km east of Dhaka, Bangladesh). This gas field still holds natural gas resources of 12.8 million tons of LNG equivalent, but is close to abandonment due to a low reservoir pressure. Consequently, applying enhanced gas recovery (EGR) by injection of excess carbon dioxide from the coupled UCG-urea process may mitigate carbon emissions and support natural gas production from the Bahkrabad gas field. To carry out an integrated techno-economic assessment of the coupled system, we adapted the techno-economic UCG-CCS model developed by Nakaten et al. (2014) to consider the urea and EGR processes. Reservoir simulations addressing EGR in the Bakhrabad gas field by utilization of excess carbon dioxide from the UCG process were carried out to account for the induced pressure increase in the reservoir, and thus additional gas recovery potentials. The Jamalganj coal field in Northwest Bangladesh provides favorable geological and infrastructural conditions for a UCG operation at coal seam depths of 640 m to 1,158 m. Excess CO2 can be transported via existing pipeline networks to the Bahkrabad gas field (about 300 km distance from the coal deposit) to be injected in the scope of the scheduled EGR operation. Our techno-economic modeling results considering EGR reservoir simulations demonstrate that an economic and carbon neutral operation of UCG combined with fertilizer production and CCS is feasible. The suggested approach may provide a bridging technology to tackle fertilizer and power supply shortages in Bangladesh, and in addition support further production from depleting natural gas deposits. References Kempka, T., Plötz, M.L., Hamann, J., Deowan, S.A., Azzam, R. (2010) Carbon dioxide utilisation for carbamide production by application of the coupled UCG-urea process. Energy Procedia 4: 2200-2205. Nakaten, N., Schlüter, R., Azzam, R., Kempka, T. (2014) Development of a techno-economic model for dynamic calculation of COE, energy demand and CO2 emissions of an integrated UCG-CCS process. Energy (in print). Doi 10.1016/j.energy.2014.01.014
Jain, Veena; Das, Taposh K; Pruthi, Gunjan; Shah, Naseem; Rajendiran, Suresh
2015-01-01
Change in color and loss of marginal adaptation of tooth colored restorative materials is not acceptable. Bleaching is commonly used for treating discolored teeth. However, the literature is scanty regarding its effect on color and marginal adaptation of direct and indirect composite laminate veneers (CLVs) under in vivo conditions. Purpose of the study was to determine the effect of bleaching on color change and marginal adaptation of direct and indirect CLVs over a period of time when exposed to the oral environment. For this purpose, a total of 14 subjects irrespective of age and sex indicated for CLV restorations on maxillary anterior teeth were selected following the inclusion and exclusion criteria. For each subject, indirect CLVs were fabricated and looted in the first quadrant (Group 1) and direct CLV's (Group 2), were given in the second quadrant. Color change was assessed clinically using intra-oral digital spectrophotometer and marginal adaptation was assessed on epoxy resin replica of the tooth-restoration interface under scanning electron microscope. After 6 months, the subjects underwent a home bleaching regimen for 14 days using 10% carbamide peroxide. The assessment of color change and marginal adaptation was done at 6 months after veneering (0-180 days), immediately after the bleaching regimen (0-194 days) and 3 months after the bleaching regimen (0-284 days). The difference in median color change (ΔE) between the groups was tested using Wilcoxon rank sum test while the median color change with time within the groups was tested using Wilcoxon signed rank test. The difference in the rates of marginal adaptation was tested between the groups using Chi-square/Fisher's exact test. Bleaching led to statistically significant color change at cervical (CE), middle and incisal (IE) regions when direct and indirect composites were compared (P < 0.05). During intra-group comparison, direct CLV's showed significant color change at CE and IE regions when ΔE was compared at 180 days and 284 days (CE 10 vs. CE 30, P = 0.008, IE 10 vs. IE 30, P = 0.003). No significant differences were found when within group comparison was made for indirect laminates. Intergroup comparison between the groups showed significant difference in marginal adaptation at CE margin at all.time points (at baseline, P = 0.005; at 180 days, P = 0.007; 194 days, P = 0.025; at 284 days, P = 0.067). After bleaching, indirect CLVs performed better in terms of color stability whereas direct CLVs performed better in terms of marginal adaptation. Indirect composites should be preferred to direct composites as veneering materials as they have better color stability. Special attention should be given to their marginal adaptation especially in the CE region. Bleaching should be avoided in patients with composite restorations in the mouth.