Sample records for cardiac activation imaging

  1. Evaluation of the low dose cardiac CT imaging using ASIR technique

    NASA Astrophysics Data System (ADS)

    Fan, Jiahua; Hsieh, Jiang; Deubig, Amy; Sainath, Paavana; Crandall, Peter

    2010-04-01

    Today Cardiac imaging is one of the key driving forces for the research and development activities of Computed Tomography (CT) imaging. It requires high spatial and temporal resolution and is often associated with high radiation dose. The newly introduced ASIR technique presents an efficient method that offers the dose reduction benefits while maintaining image quality and providing fast reconstruction speed. This paper discusses the study of image quality of the ASIR technique for Cardiac CT imaging. Phantoms as well as clinical data have been evaluated to demonstrate the effectiveness of ASIR technique for Cardiac CT applications.

  2. Noninvasive reconstruction of the three-dimensional ventricular activation sequence during pacing and ventricular tachycardia in the rabbit heart.

    PubMed

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2011-01-01

    Ventricular arrhythmias represent one of leading causes for sudden cardiac death, a significant problem in public health. Noninvasive imaging of cardiac electric activities associated with ventricular arrhythmias plays an important role in better our understanding of the mechanisms and optimizing the treatment options. The present study aims to rigorously validate a novel three-dimensional (3-D) cardiac electrical imaging (3-DCEI) technique with the aid of 3-D intra-cardiac mapping during paced rhythm and ventricular tachycardia (VT) in the rabbit heart. Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in thirteen healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous norepinephrine (NE). The non-invasively imaged activation sequence correlated well with invasively measured counterparts, with a correlation coefficient of 0.72 and a relative error of 0.30 averaged over all paced beats and NE-induced PVCs and VT beats. The averaged distance from imaged site of initial activation to measured site determined from intra-cardiac mapping was ∼5mm. These promising results suggest that 3-DCEI is feasible to non-invasively localize the origins and image activation sequence of focal ventricular arrhythmias.

  3. Noninvasive Imaging of Three-dimensional Cardiac Activation Sequence during Pacing and Ventricular Tachycardia

    PubMed Central

    Han, Chengzong; Pogwizd, Steven M.; Killingsworth, Cheryl R.; He, Bin

    2011-01-01

    Background Imaging cardiac excitation within ventricular myocardium is important in the treatment of cardiac arrhythmias and might help improve our understanding of arrhythmia mechanisms. Objective This study aims to rigorously assess the imaging performance of a three-dimensional (3-D) cardiac electrical imaging (3-DCEI) technique with the aid of 3-D intra-cardiac mapping from up to 216 intramural sites during paced rhythm and norepinephrine (NE) induced ventricular tachycardia (VT) in the rabbit heart. Methods Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in thirteen healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous NE. Computer tomography images were obtained to construct geometry model. Results The non-invasively imaged activation sequence correlated well with invasively measured counterparts, with a correlation coefficient of 0.72±0.04, and a relative error of 0.30±0.02 averaged over 520 paced beats as well as 73 NE-induced PVCs and VT beats. All PVCs and VT beats initiated in the subendocardium by a nonreentrant mechanism. The averaged distance from imaged site of initial activation to pacing site or site of arrhythmias determined from intra-cardiac mapping was ~5mm. For dual-site pacing, the double origins were identified when they were located at contralateral sides of ventricles or at the lateral wall and the apex. Conclusion 3-DCEI can non-invasively delineate important features of focal or multi-focal ventricular excitation. It offers the potential to aid in localizing the origins and imaging activation sequence of ventricular arrhythmias, and to provide noninvasive assessment of the underlying arrhythmia mechanisms. PMID:21397046

  4. Efficacy of full-fat milk and diluted lemon juice in reducing infra-cardiac activity of (99m)Tc sestamibi during myocardial perfusion imaging.

    PubMed

    Purbhoo, Khushica; Vangu, Mboyo Di Tamba Willy

    2015-01-01

    When using (99m)Tc sestamibi for myocardial perfusion imaging, increased splanchnic activity creates a problem in the visual and quantitative interpretation of the inferior and infero-septal walls of the left ventricle. We sought to determine whether the administration of diluted lemon juice or full-fat milk would be effective in reducing interfering infra-cardiac activity and therefore result in an improvement in image quality. We compared the administration of full-fat milk and diluted lemon juice to a control group that had no intervention. The study was carried out prospectively. All patients referred to our institution for myocardial perfusion imaging from November 2009 to May 2012 were invited to be enrolled in the study. A total of 630 patients were randomised into three groups. Group 0 (G0), 246 patients, were given diluted lemon juice, group 1 (G1), 313 patients, were given full-fat milk, and group 2 (G2), 71 patients, had no intervention (control group). A routine two-day protocol was used and the patients were given the same intervention on both days. Raw data of both the stress and rest images were visually assessed for the presence of infra-cardiac activity, and quantitative grading of the relative intensity of myocardial activity to infra-cardiac activity was determined. The physicians were blinded to the intervention received and the data were reviewed simultaneously. The overall incidence of interfering infra-cardiac activity at stress was 84.1, 84.5 and 96.6% in G0, G1 and G2, respectively (p = 0.005). At rest it was 91.7, 90.1 and 100% in G0, G1 and G2, respectively (p = 0.0063). The visual and quantitative results favoured both milk and lemon juice in reducing the amount of interfering infra-cardiac activity versus no intervention. The administration of milk or lemon juice resulted in a significant decrease in the intensity of infra-cardiac activity compared to the control group. This reduction in intensity was even more significant in the milk group for patients assessed during rest myocardial perfusion imaging.

  5. [Image processing applying in analysis of motion features of cultured cardiac myocyte in rat].

    PubMed

    Teng, Qizhi; He, Xiaohai; Luo, Daisheng; Wang, Zhengrong; Zhou, Beiyi; Yuan, Zhirun; Tao, Dachang

    2007-02-01

    Study of mechanism of medicine actions, by quantitative analysis of cultured cardiac myocyte, is one of the cutting edge researches in myocyte dynamics and molecular biology. The characteristics of cardiac myocyte auto-beating without external stimulation make the research sense. Research of the morphology and cardiac myocyte motion using image analysis can reveal the fundamental mechanism of medical actions, increase the accuracy of medicine filtering, and design the optimal formula of medicine for best medical treatments. A system of hardware and software has been built with complete sets of functions including living cardiac myocyte image acquisition, image processing, motion image analysis, and image recognition. In this paper, theories and approaches are introduced for analysis of living cardiac myocyte motion images and implementing quantitative analysis of cardiac myocyte features. A motion estimation algorithm is used for motion vector detection of particular points and amplitude and frequency detection of a cardiac myocyte. Beatings of cardiac myocytes are sometimes very small. In such case, it is difficult to detect the motion vectors from the particular points in a time sequence of images. For this reason, an image correlation theory is employed to detect the beating frequencies. Active contour algorithm in terms of energy function is proposed to approximate the boundary and detect the changes of edge of myocyte.

  6. Toward microendoscopy-inspired cardiac optogenetics in vivo: technical overview and perspective

    NASA Astrophysics Data System (ADS)

    Klimas, Aleksandra; Entcheva, Emilia

    2014-08-01

    The ability to perform precise, spatially localized actuation and measurements of electrical activity in the heart is crucial in understanding cardiac electrophysiology and devising new therapeutic solutions for control of cardiac arrhythmias. Current cardiac imaging techniques (i.e. optical mapping) employ voltage- or calcium-sensitive fluorescent dyes to visualize the electrical signal propagation through cardiac syncytium in vitro or in situ with very high-spatiotemporal resolution. The extension of optogenetics into the cardiac field, where cardiac tissue is genetically altered to express light-sensitive ion channels allowing electrical activity to be elicited or suppressed in a precise cell-specific way, has opened the possibility for all-optical interrogation of cardiac electrophysiology. In vivo application of cardiac optogenetics faces multiple challenges and necessitates suitable optical systems employing fiber optics to actuate and sense electrical signals. In this technical perspective, we present a compendium of clinically relevant access routes to different parts of the cardiac electrical conduction system based on currently employed catheter imaging systems and determine the quantitative size constraints for endoscopic cardiac optogenetics. We discuss the relevant technical advancements in microendoscopy, cardiac imaging, and optogenetics and outline the strategies for combining them to create a portable, miniaturized fiber-based system for all-optical interrogation of cardiac electrophysiology in vivo.

  7. Mapping cardiac fiber orientations from high-resolution DTI to high-frequency 3D ultrasound

    NASA Astrophysics Data System (ADS)

    Qin, Xulei; Wang, Silun; Shen, Ming; Zhang, Xiaodong; Wagner, Mary B.; Fei, Baowei

    2014-03-01

    The orientation of cardiac fibers affects the anatomical, mechanical, and electrophysiological properties of the heart. Although echocardiography is the most common imaging modality in clinical cardiac examination, it can only provide the cardiac geometry or motion information without cardiac fiber orientations. If the patient's cardiac fiber orientations can be mapped to his/her echocardiography images in clinical examinations, it may provide quantitative measures for diagnosis, personalized modeling, and image-guided cardiac therapies. Therefore, this project addresses the feasibility of mapping personalized cardiac fiber orientations to three-dimensional (3D) ultrasound image volumes. First, the geometry of the heart extracted from the MRI is translated to 3D ultrasound by rigid and deformable registration. Deformation fields between both geometries from MRI and ultrasound are obtained after registration. Three different deformable registration methods were utilized for the MRI-ultrasound registration. Finally, the cardiac fiber orientations imaged by DTI are mapped to ultrasound volumes based on the extracted deformation fields. Moreover, this study also demonstrated the ability to simulate electricity activations during the cardiac resynchronization therapy (CRT) process. The proposed method has been validated in two rat hearts and three canine hearts. After MRI/ultrasound image registration, the Dice similarity scores were more than 90% and the corresponding target errors were less than 0.25 mm. This proposed approach can provide cardiac fiber orientations to ultrasound images and can have a variety of potential applications in cardiac imaging.

  8. Detection of Cardiac Quiescence from B-Mode Echocardiography Using a Correlation-Based Frame-to-Frame Deviation Measure

    PubMed Central

    Mcclellan, James H.; Ravichandran, Lakshminarayan; Tridandapani, Srini

    2013-01-01

    Two novel methods for detecting cardiac quiescent phases from B-mode echocardiography using a correlation-based frame-to-frame deviation measure were developed. Accurate knowledge of cardiac quiescence is crucial to the performance of many imaging modalities, including computed tomography coronary angiography (CTCA). Synchronous electrocardiography (ECG) and echocardiography data were obtained from 10 healthy human subjects (four male, six female, 23–45 years) and the interventricular septum (IVS) was observed using the apical four-chamber echocardiographic view. The velocity of the IVS was derived from active contour tracking and verified using tissue Doppler imaging echocardiography methods. In turn, the frame-to-frame deviation methods for identifying quiescence of the IVS were verified using active contour tracking. The timing of the diastolic quiescent phase was found to exhibit both inter- and intra-subject variability, suggesting that the current method of CTCA gating based on the ECG is suboptimal and that gating based on signals derived from cardiac motion are likely more accurate in predicting quiescence for cardiac imaging. Two robust and efficient methods for identifying cardiac quiescent phases from B-mode echocardiographic data were developed and verified. The methods presented in this paper will be used to develop new CTCA gating techniques and quantify the resulting potential improvement in CTCA image quality. PMID:26609501

  9. Physiome-model-based state-space framework for cardiac deformation recovery.

    PubMed

    Wong, Ken C L; Zhang, Heye; Liu, Huafeng; Shi, Pengcheng

    2007-11-01

    To more reliably recover cardiac information from noise-corrupted, patient-specific measurements, it is essential to employ meaningful constraining models and adopt appropriate optimization criteria to couple the models with the measurements. Although biomechanical models have been extensively used for myocardial motion recovery with encouraging results, the passive nature of such constraints limits their ability to fully count for the deformation caused by active forces of the myocytes. To overcome such limitations, we propose to adopt a cardiac physiome model as the prior constraint for cardiac motion analysis. The cardiac physiome model comprises an electric wave propagation model, an electromechanical coupling model, and a biomechanical model, which are connected through a cardiac system dynamics for a more complete description of the macroscopic cardiac physiology. Embedded within a multiframe state-space framework, the uncertainties of the model and the patient's measurements are systematically dealt with to arrive at optimal cardiac kinematic estimates and possibly beyond. Experiments have been conducted to compare our proposed cardiac-physiome-model-based framework with the solely biomechanical model-based framework. The results show that our proposed framework recovers more accurate cardiac deformation from synthetic data and obtains more sensible estimates from real magnetic resonance image sequences. With the active components introduced by the cardiac physiome model, cardiac deformations recovered from patient's medical images are more physiologically plausible.

  10. Mapping of Cardiac Electrical Activation with Electromechanical Wave Imaging: An in silico-in vivo Reciprocity Study

    PubMed Central

    Provost, Jean; Gurev, Viatcheslav; Trayanova, Natalia; Konofagou, Elisa E.

    2011-01-01

    Background Electromechanical Wave Imaging (EWI) is an entirely non-invasive, ultrasound-based imaging method capable of mapping the electromechanical activation sequence of the ventricles in vivo. Given the broad accessibility of ultrasound scanners in the clinic, the application of EWI could constitute a flexible surrogate for the 3D electrical activation. Objective The purpose of this report is to reproduce the electromechanical wave (EW) using an anatomically-realistic electromechanical model, and establish the capability of EWI to map the electrical activation sequence in vivo when pacing from different locations. Methods EWI was performed in one canine during pacing from three different sites. A high-resolution dynamic model of coupled cardiac electromechanics of the canine heart was used to predict the experimentally recorded electromechanical wave. The simulated 3D electrical activation sequence was then compared with the experimental EW. Results The electrical activation sequence and the EW were highly correlated for all pacing sites. The relationship between the electrical activation and the EW onset was found to be linear with a slope of 1.01 to 1.17 for different pacing schemes and imaging angles. Conclusions The accurate reproduction of the EW in simulations indicates that the model framework is capable of accurately representing the cardiac electromechanics and thus testing new hypotheses. The one-to-one correspondence between the electrical activation sequence and the EW indicates that EWI could be used to map the cardiac electrical activity. This opens the door for further exploration of the technique in assisting in the early detection, diagnosis and treatment monitoring of rhythm dysfunction. PMID:21185403

  11. Noninvasive imaging of three-dimensional cardiac activation sequence during pacing and ventricular tachycardia.

    PubMed

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2011-08-01

    Imaging cardiac excitation within ventricular myocardium is important in the treatment of cardiac arrhythmias and might help improve our understanding of arrhythmia mechanisms. This study sought to rigorously assess the imaging performance of a 3-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of 3D intracardiac mapping from up to 216 intramural sites during paced rhythm and norepinephrine (NE)-induced ventricular tachycardia (VT) in the rabbit heart. Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in 13 healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous NE. Computed tomography images were obtained to construct geometry models. The noninvasively imaged activation sequence correlated well with invasively measured counterpart, with a correlation coefficient of 0.72 ± 0.04, and a relative error of 0.30 ± 0.02 averaged over 520 paced beats as well as 73 NE-induced PVCs and VT beats. All PVCs and VT beats initiated in the subendocardium by a nonreentrant mechanism. The averaged distance from the imaged site of initial activation to the pacing site or site of arrhythmias determined from intracardiac mapping was ∼5 mm. For dual-site pacing, the double origins were identified when they were located at contralateral sides of ventricles or at the lateral wall and the apex. 3DCEI can noninvasively delineate important features of focal or multifocal ventricular excitation. It offers the potential to aid in localizing the origins and imaging activation sequences of ventricular arrhythmias, and to provide noninvasive assessment of the underlying arrhythmia mechanisms. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  12. Unusual scarring patterns on cardiac magnetic resonance imaging: A potentially treatable etiology not to be missed.

    PubMed

    Jordan, Andrew; Lyne, Jonathan; Wong, Tom

    2010-04-01

    A case of cardiomyopathy and ventricular tachycardia previously assumed to be idiopathic in origin is described. Investigation with cardiac magnetic resonance imaging prompted the diagnosis and successful treatment of an underlying disorder based on typical scarring patterns seen with late gadolinium enhancement. The present report suggests that clinicians should have a low threshold for actively excluding this condition in patients presenting with cardiomyopathy, even in the absence of other disease features, particularly if typical scarring patterns are found on cardiac magnetic resonance imaging because disease-specific therapy appears to significantly improve both symptoms and prognosis.

  13. Dynamic cardiac PET imaging: extraction of time-activity curves using ICA and a generalized Gaussian distribution model.

    PubMed

    Mabrouk, Rostom; Dubeau, François; Bentabet, Layachi

    2013-01-01

    Kinetic modeling of metabolic and physiologic cardiac processes in small animals requires an input function (IF) and a tissue time-activity curves (TACs). In this paper, we present a mathematical method based on independent component analysis (ICA) to extract the IF and the myocardium's TACs directly from dynamic positron emission tomography (PET) images. The method assumes a super-Gaussian distribution model for the blood activity, and a sub-Gaussian distribution model for the tissue activity. Our appreach was applied on 22 PET measurement sets of small animals, which were obtained from the three most frequently used cardiac radiotracers, namely: desoxy-fluoro-glucose ((18)F-FDG), [(13)N]-ammonia, and [(11)C]-acetate. Our study was extended to PET human measurements obtained with the Rubidium-82 ((82) Rb) radiotracer. The resolved mathematical IF values compare favorably to those derived from curves extracted from regions of interest (ROI), suggesting that the procedure presents a reliable alternative to serial blood sampling for small-animal cardiac PET studies.

  14. Effect of specific activity on cardiac uptake of iodine-123-MIBG.

    PubMed

    Farahati, J; Bier, D; Scheubeck, M; Lassmann, M; Schelper, L F; Grelle, I; Hanscheid, H; Biko, J; Graefe, K H; Reiners, C

    1997-03-01

    Radioiodinated meta-iodobenzylguanidine (MIBG), an analog of norepinephrine, has been used to assess myocardial sympathetic innervation. Recent in vivo studies predict enhanced cardiac uptake of this radiopharmaceutical with high specific activity. To clarify the effect of specific activity on cardiac uptake of radioiodinated MIBG, the distribution and kinetics of no-carrier-added [123I]MIBG (> or = 7.4 TBq/mumol) were compared with those of commercial [123I]MIBG (approximately 74 MBq/mumol) in three healthy volunteers by serial imaging and blood sampling. Higher specific activity result in higher uptake of radioiodinated MIBG in all volunteers in the heart (p < 0.05) and liver (p < 0.05) but not in the lung (p = 0.26). Due to rapid deiodination, a more pronounced accumulation of radioactivity was present in plasma after no-carrier-added MIBG than commercial [123I]MIBG, resulting in higher background and thyroid activity after administration of the former. Calculated heart-to-liver (p = 0.96) and heart-to-lung (p = 0.42) count ratios in all volunteers revealed no significant improvement in cardiac imaging with no-carrier-added [123I]MIBG compared to commercial [123I]MIBG. This study highlights the appreciably higher in vivo deiodination of no-carrier-added [123I]MIBG compared to commercial preparation of [123I]MIBG in humans. Cardiac images acquired with no-carrier-added [123I]MIBG do not seem to be superior to those obtained with commercial MIBG.

  15. Images as drivers of progress in cardiac computational modelling

    PubMed Central

    Lamata, Pablo; Casero, Ramón; Carapella, Valentina; Niederer, Steve A.; Bishop, Martin J.; Schneider, Jürgen E.; Kohl, Peter; Grau, Vicente

    2014-01-01

    Computational models have become a fundamental tool in cardiac research. Models are evolving to cover multiple scales and physical mechanisms. They are moving towards mechanistic descriptions of personalised structure and function, including effects of natural variability. These developments are underpinned to a large extent by advances in imaging technologies. This article reviews how novel imaging technologies, or the innovative use and extension of established ones, integrate with computational models and drive novel insights into cardiac biophysics. In terms of structural characterization, we discuss how imaging is allowing a wide range of scales to be considered, from cellular levels to whole organs. We analyse how the evolution from structural to functional imaging is opening new avenues for computational models, and in this respect we review methods for measurement of electrical activity, mechanics and flow. Finally, we consider ways in which combined imaging and modelling research is likely to continue advancing cardiac research, and identify some of the main challenges that remain to be solved. PMID:25117497

  16. Iodine-123 metaiodobenzylguanidine imaging of the heart in idiopathic congestive cardiomyopathy and cardiac transplants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glowniak, J.V.; Turner, F.E.; Gray, L.L.

    1989-07-01

    Iodine-123 metaiodobenzylguanidine ((/sup 123/I)MIBG) is a norepinephrine analog which can be used to image the sympathetic innervation of the heart. In this study, cardiac imaging with (/sup 123/I)MIBG was performed in patients with idiopathic congestive cardiomyopathy and compared to normal controls. Initial uptake, half-time of tracer within the heart, and heart to lung ratios were all significantly reduced in patients compared to normals. Uptake in lungs, liver, salivary glands, and spleen was similar in controls and patients with cardiomyopathy indicating that decreased MIBG uptake was not a generalized abnormality in these patients. Iodine-123 MIBG imaging was also performed in cardiacmore » transplant patients to determine cardiac nonneuronal uptake. Uptake in transplants was less than 10% of normals in the first 2 hr and nearly undetectable after 16 hr. The decreased uptake of MIBG suggests cardiac sympathetic nerve dysfunction while the rapid washout of MIBG from the heart suggests increased cardiac sympathetic nerve activity in idiopathic congestive cardiomyopathy.« less

  17. Noise removal using factor analysis of dynamic structures: application to cardiac gated studies.

    PubMed

    Bruyant, P P; Sau, J; Mallet, J J

    1999-10-01

    Factor analysis of dynamic structures (FADS) facilitates the extraction of relevant data, usually with physiologic meaning, from a dynamic set of images. The result of this process is a set of factor images and curves plus some residual activity. The set of factor images and curves can be used to retrieve the original data with reduced noise using an inverse factor analysis process (iFADS). This improvement in image quality is expected because the inverse process does not use the residual activity, assumed to be made of noise. The goal of this work is to quantitate and assess the efficiency of this method on gated cardiac images. A computer simulation of a planar cardiac gated study was performed. The simulated images were added with noise and processed by the FADS-iFADS program. The signal-to-noise ratios (SNRs) were compared between original and processed data. Planar gated cardiac studies from 10 patients were tested. The data processed by FADS-iFADS were subtracted to the original data. The result of the substraction was studied to evaluate its noisy nature. The SNR is about five times greater after the FADS-iFADS process. The difference between original and processed data is noise only, i.e., processed data equals original data minus some white noise. The FADS-iFADS process is successful in the removal of an important part of the noise and therefore is a tool to improve the image quality of cardiac images. This tool does not decrease the spatial resolution (compared with smoothing filters) and does not lose details (compared with frequential filters). Once the number of factors is chosen, this method is not operator dependent.

  18. Evaluation of respiratory and cardiac motion correction schemes in dual gated PET/CT cardiac imaging.

    PubMed

    Lamare, F; Le Maitre, A; Dawood, M; Schäfers, K P; Fernandez, P; Rimoldi, O E; Visvikis, D

    2014-07-01

    Cardiac imaging suffers from both respiratory and cardiac motion. One of the proposed solutions involves double gated acquisitions. Although such an approach may lead to both respiratory and cardiac motion compensation there are issues associated with (a) the combination of data from cardiac and respiratory motion bins, and (b) poor statistical quality images as a result of using only part of the acquired data. The main objective of this work was to evaluate different schemes of combining binned data in order to identify the best strategy to reconstruct motion free cardiac images from dual gated positron emission tomography (PET) acquisitions. A digital phantom study as well as seven human studies were used in this evaluation. PET data were acquired in list mode (LM). A real-time position management system and an electrocardiogram device were used to provide the respiratory and cardiac motion triggers registered within the LM file. Acquired data were subsequently binned considering four and six cardiac gates, or the diastole only in combination with eight respiratory amplitude gates. PET images were corrected for attenuation, but no randoms nor scatter corrections were included. Reconstructed images from each of the bins considered above were subsequently used in combination with an affine or an elastic registration algorithm to derive transformation parameters allowing the combination of all acquired data in a particular position in the cardiac and respiratory cycles. Images were assessed in terms of signal-to-noise ratio (SNR), contrast, image profile, coefficient-of-variation (COV), and relative difference of the recovered activity concentration. Regardless of the considered motion compensation strategy, the nonrigid motion model performed better than the affine model, leading to higher SNR and contrast combined with a lower COV. Nevertheless, when compensating for respiration only, no statistically significant differences were observed in the performance of the two motion models considered. Superior image SNR and contrast were seen using the affine respiratory motion model in combination with the diastole cardiac bin in comparison to the use of the whole cardiac cycle. In contrast, when simultaneously correcting for cardiac beating and respiration, the elastic respiratory motion model outperformed the affine model. In this context, four cardiac bins associated with eight respiratory amplitude bins seemed to be adequate. Considering the compensation of respiratory motion effects only, both affine and elastic based approaches led to an accurate resizing and positioning of the myocardium. The use of the diastolic phase combined with an affine model based respiratory motion correction may therefore be a simple approach leading to significant quality improvements in cardiac PET imaging. However, the best performance was obtained with the combined correction for both cardiac and respiratory movements considering all the dual-gated bins independently through the use of an elastic model based motion compensation.

  19. Pain-related somatosensory evoked potentials and functional brain magnetic resonance in the evaluation of neurologic recovery after cardiac arrest: a case study of three patients.

    PubMed

    Zanatta, Paolo; Messerotti Benvenuti, Simone; Baldanzi, Fabrizio; Bendini, Matteo; Saccavini, Marsilio; Tamari, Wadih; Palomba, Daniela; Bosco, Enrico

    2012-03-31

    This case series investigates whether painful electrical stimulation increases the early prognostic value of both somatosensory-evoked potentials and functional magnetic resonance imaging in comatose patients after cardiac arrest. Three single cases with hypoxic-ischemic encephalopathy were considered. A neurophysiological evaluation with an electroencephalogram and somatosensory-evoked potentials during increased electrical stimulation in both median nerves was performed within five days of cardiac arrest. Each patient also underwent a functional magnetic resonance imaging evaluation with the same neurophysiological protocol one month after cardiac arrest. One patient, who completely recovered, showed a middle latency component at a high intensity of stimulation and the activation of all brain areas involved in cerebral pain processing. One patient in a minimally conscious state only showed the cortical somatosensory response and the activation of the primary somatosensory cortex. The last patient, who was in a vegetative state, did not show primary somatosensory evoked potentials; only the activation of subcortical brain areas occurred. These preliminary findings suggest that the pain-related somatosensory evoked potentials performed to increase the prognosis of comatose patients after cardiac arrest are associated with regional brain activity showed by functional magnetic resonance imaging during median nerves electrical stimulation. More importantly, this cases report also suggests that somatosensory evoked potentials and functional magnetic resonance imaging during painful electrical stimulation may be sensitive and complementary methods to predict the neurological outcome in the acute phase of coma. Thus, pain-related somatosensory-evoked potentials may be a reliable and a cost-effective tool for planning the early diagnostic evaluation of comatose patients.

  20. Imaging cardiac activation sequence during ventricular tachycardia in a canine model of nonischemic heart failure.

    PubMed

    Han, Chengzong; Pogwizd, Steven M; Yu, Long; Zhou, Zhaoye; Killingsworth, Cheryl R; He, Bin

    2015-01-15

    Noninvasive cardiac activation imaging of ventricular tachycardia (VT) is important in the clinical diagnosis and treatment of arrhythmias in heart failure (HF) patients. This study investigated the ability of the three-dimensional cardiac electrical imaging (3DCEI) technique for characterizing the activation patterns of spontaneously occurring and norepinephrine (NE)-induced VTs in a newly developed arrhythmogenic canine model of nonischemic HF. HF was induced by aortic insufficiency followed by aortic constriction in three canines. Up to 128 body-surface ECGs were measured simultaneously with bipolar recordings from up to 232 intramural sites in a closed-chest condition. Data analysis was performed on the spontaneously occurring VTs (n=4) and the NE-induced nonsustained VTs (n=8) in HF canines. Both spontaneously occurring and NE-induced nonsustained VTs initiated by a focal mechanism primarily from the subendocardium, but occasionally from the subepicardium of left ventricle. Most focal initiation sites were located at apex, right ventricular outflow tract, and left lateral wall. The NE-induced VTs were longer, more rapid, and had more focal sites than the spontaneously occurring VTs. Good correlation was obtained between imaged activation sequence and direct measurements (averaged correlation coefficient of ∼0.70 over 135 VT beats). The reconstructed initiation sites were ∼10 mm from measured initiation sites, suggesting good localization in such a large animal model with cardiac size similar to a human. Both spontaneously occurring and NE-induced nonsustained VTs had focal initiation in this canine model of nonischemic HF. 3DCEI is feasible to image the activation sequence and help define arrhythmia mechanism of nonischemic HF-associated VTs. Copyright © 2015 the American Physiological Society.

  1. A three-dimensional model-based partial volume correction strategy for gated cardiac mouse PET imaging

    NASA Astrophysics Data System (ADS)

    Dumouchel, Tyler; Thorn, Stephanie; Kordos, Myra; DaSilva, Jean; Beanlands, Rob S. B.; deKemp, Robert A.

    2012-07-01

    Quantification in cardiac mouse positron emission tomography (PET) imaging is limited by the imaging spatial resolution. Spillover of left ventricle (LV) myocardial activity into adjacent organs results in partial volume (PV) losses leading to underestimation of myocardial activity. A PV correction method was developed to restore accuracy of the activity distribution for FDG mouse imaging. The PV correction model was based on convolving an LV image estimate with a 3D point spread function. The LV model was described regionally by a five-parameter profile including myocardial, background and blood activities which were separated into three compartments by the endocardial radius and myocardium wall thickness. The PV correction was tested with digital simulations and a physical 3D mouse LV phantom. In vivo cardiac FDG mouse PET imaging was also performed. Following imaging, the mice were sacrificed and the tracer biodistribution in the LV and liver tissue was measured using a gamma-counter. The PV correction algorithm improved recovery from 50% to within 5% of the truth for the simulated and measured phantom data and image uniformity by 5-13%. The PV correction algorithm improved the mean myocardial LV recovery from 0.56 (0.54) to 1.13 (1.10) without (with) scatter and attenuation corrections. The mean image uniformity was improved from 26% (26%) to 17% (16%) without (with) scatter and attenuation corrections applied. Scatter and attenuation corrections were not observed to significantly impact PV-corrected myocardial recovery or image uniformity. Image-based PV correction algorithm can increase the accuracy of PET image activity and improve the uniformity of the activity distribution in normal mice. The algorithm may be applied using different tracers, in transgenic models that affect myocardial uptake, or in different species provided there is sufficient image quality and similar contrast between the myocardium and surrounding structures.

  2. Computational Chemical Imaging for Cardiovascular Pathology: Chemical Microscopic Imaging Accurately Determines Cardiac Transplant Rejection

    PubMed Central

    Tiwari, Saumya; Reddy, Vijaya B.; Bhargava, Rohit; Raman, Jaishankar

    2015-01-01

    Rejection is a common problem after cardiac transplants leading to significant number of adverse events and deaths, particularly in the first year of transplantation. The gold standard to identify rejection is endomyocardial biopsy. This technique is complex, cumbersome and requires a lot of expertise in the correct interpretation of stained biopsy sections. Traditional histopathology cannot be used actively or quickly during cardiac interventions or surgery. Our objective was to develop a stain-less approach using an emerging technology, Fourier transform infrared (FT-IR) spectroscopic imaging to identify different components of cardiac tissue by their chemical and molecular basis aided by computer recognition, rather than by visual examination using optical microscopy. We studied this technique in assessment of cardiac transplant rejection to evaluate efficacy in an example of complex cardiovascular pathology. We recorded data from human cardiac transplant patients’ biopsies, used a Bayesian classification protocol and developed a visualization scheme to observe chemical differences without the need of stains or human supervision. Using receiver operating characteristic curves, we observed probabilities of detection greater than 95% for four out of five histological classes at 10% probability of false alarm at the cellular level while correctly identifying samples with the hallmarks of the immune response in all cases. The efficacy of manual examination can be significantly increased by observing the inherent biochemical changes in tissues, which enables us to achieve greater diagnostic confidence in an automated, label-free manner. We developed a computational pathology system that gives high contrast images and seems superior to traditional staining procedures. This study is a prelude to the development of real time in situ imaging systems, which can assist interventionists and surgeons actively during procedures. PMID:25932912

  3. Noninvasive cardiac activation imaging of ventricular arrhythmias during drug-induced QT prolongation in the rabbit heart.

    PubMed

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; Zhou, Zhaoye; He, Bin

    2013-10-01

    Imaging myocardial activation from noninvasive body surface potentials promises to aid in both cardiovascular research and clinical medicine. To investigate the ability of a noninvasive 3-dimensional cardiac electrical imaging technique for characterizing the activation patterns of dynamically changing ventricular arrhythmias during drug-induced QT prolongation in rabbits. Simultaneous body surface potential mapping and 3-dimensional intracardiac mapping were performed in a closed-chest condition in 8 rabbits. Data analysis was performed on premature ventricular complexes, couplets, and torsades de pointes (TdP) induced during intravenous administration of clofilium and phenylephrine with combinations of various infusion rates. The drug infusion led to a significant increase in the QT interval (from 175 ± 7 to 274 ± 31 ms) and rate-corrected QT interval (from 183 ± 5 to 262 ± 21 ms) during the first dose cycle. All the ectopic beats initiated by a focal activation pattern. The initial beat of TdPs arose at the focal site, whereas the subsequent beats were due to focal activity from different sites or 2 competing focal sites. The imaged results captured the dynamic shift of activation patterns and were in good correlation with the simultaneous measurements, with a correlation coefficient of 0.65 ± 0.02 averaged over 111 ectopic beats. Sites of initial activation were localized to be ~5 mm from the directly measured initiation sites. The 3-dimensional cardiac electrical imaging technique could localize the origin of activation and image activation sequence of TdP during QT prolongation induced by clofilium and phenylephrine in rabbits. It offers the potential to noninvasively investigate the proarrhythmic effects of drug infusion and assess the mechanisms of arrhythmias on a beat-to-beat basis. © 2013 Heart Rhythm Society. All rights reserved.

  4. Model-based imaging of cardiac electrical function in human atria

    NASA Astrophysics Data System (ADS)

    Modre, Robert; Tilg, Bernhard; Fischer, Gerald; Hanser, Friedrich; Messnarz, Bernd; Schocke, Michael F. H.; Kremser, Christian; Hintringer, Florian; Roithinger, Franz

    2003-05-01

    Noninvasive imaging of electrical function in the human atria is attained by the combination of data from electrocardiographic (ECG) mapping and magnetic resonance imaging (MRI). An anatomical computer model of the individual patient is the basis for our computer-aided diagnosis of cardiac arrhythmias. Three patients suffering from Wolff-Parkinson-White syndrome, from paroxymal atrial fibrillation, and from atrial flutter underwent an electrophysiological study. After successful treatment of the cardiac arrhythmia with invasive catheter technique, pacing protocols with stimuli at several anatomical sites (coronary sinus, left and right pulmonary vein, posterior site of the right atrium, right atrial appendage) were performed. Reconstructed activation time (AT) maps were validated with catheter-based electroanatomical data, with invasively determined pacing sites, and with pacing at anatomical markers. The individual complex anatomical model of the atria of each patient in combination with a high-quality mesh optimization enables accurate AT imaging, resulting in a localization error for the estimated pacing sites within 1 cm. Our findings may have implications for imaging of atrial activity in patients with focal arrhythmias.

  5. Multimodality cardiac imaging at IRCCS Policlinico San Donato: a new interdisciplinary vision.

    PubMed

    Lombardi, Massimo; Secchi, Francesco; Pluchinotta, Francesca R; Castelvecchio, Serenella; Montericcio, Vincenzo; Camporeale, Antonia; Bandera, Francesco

    2016-04-28

    Multimodality imaging is the efficient integration of various methods of cardiovascular imaging to improve the ability to diagnose, guide therapy, or predict outcome. This approach implies both the availability of different technologies in a single unit and the presence of dedicated staff with cardiologic and radiologic background and certified competence in more than one imaging technique. Interaction with clinical practice and existence of research programmes and educational activities are pivotal for the success of this model. The aim of this paper is to describe the multimodality cardiac imaging programme recently started at San Donato Hospital.

  6. Quantitatively accurate activity measurements with a dedicated cardiac SPECT camera: Physical phantom experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pourmoghaddas, Amir, E-mail: apour@ottawaheart.ca; Wells, R. Glenn

    Purpose: Recently, there has been increased interest in dedicated cardiac single photon emission computed tomography (SPECT) scanners with pinhole collimation and improved detector technology due to their improved count sensitivity and resolution over traditional parallel-hole cameras. With traditional cameras, energy-based approaches are often used in the clinic for scatter compensation because they are fast and easily implemented. Some of the cardiac cameras use cadmium-zinc-telluride (CZT) detectors which can complicate the use of energy-based scatter correction (SC) due to the low-energy tail—an increased number of unscattered photons detected with reduced energy. Modified energy-based scatter correction methods can be implemented, but theirmore » level of accuracy is unclear. In this study, the authors validated by physical phantom experiments the quantitative accuracy and reproducibility of easily implemented correction techniques applied to {sup 99m}Tc myocardial imaging with a CZT-detector-based gamma camera with multiple heads, each with a single-pinhole collimator. Methods: Activity in the cardiac compartment of an Anthropomorphic Torso phantom (Data Spectrum Corporation) was measured through 15 {sup 99m}Tc-SPECT acquisitions. The ratio of activity concentrations in organ compartments resembled a clinical {sup 99m}Tc-sestamibi scan and was kept consistent across all experiments (1.2:1 heart to liver and 1.5:1 heart to lung). Two background activity levels were considered: no activity (cold) and an activity concentration 1/10th of the heart (hot). A plastic “lesion” was placed inside of the septal wall of the myocardial insert to simulate the presence of a region without tracer uptake and contrast in this lesion was calculated for all images. The true net activity in each compartment was measured with a dose calibrator (CRC-25R, Capintec, Inc.). A 10 min SPECT image was acquired using a dedicated cardiac camera with CZT detectors (Discovery NM530c, GE Healthcare), followed by a CT scan for attenuation correction (AC). For each experiment, separate images were created including reconstruction with no corrections (NC), with AC, with attenuation and dual-energy window (DEW) scatter correction (ACSC), with attenuation and partial volume correction (PVC) applied (ACPVC), and with attenuation, scatter, and PVC applied (ACSCPVC). The DEW SC method used was modified to account for the presence of the low-energy tail. Results: T-tests showed that the mean error in absolute activity measurement was reduced significantly for AC and ACSC compared to NC for both (hot and cold) datasets (p < 0.001) and that ACSC, ACPVC, and ACSCPVC show significant reductions in mean differences compared to AC (p ≤ 0.001) without increasing the uncertainty (p > 0.4). The effect of SC and PVC was significant in reducing errors over AC in both datasets (p < 0.001 and p < 0.01, respectively), resulting in a mean error of 5% ± 4%. Conclusions: Quantitative measurements of cardiac {sup 99m}Tc activity are achievable using attenuation and scatter corrections, with the authors’ dedicated cardiac SPECT camera. Partial volume corrections offer improvements in measurement accuracy in AC images and ACSC images with elevated background activity; however, these improvements are not significant in ACSC images with low background activity.« less

  7. Evaluation of respiratory and cardiac motion correction schemes in dual gated PET/CT cardiac imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lamare, F., E-mail: frederic.lamare@chu-bordeaux.fr; Fernandez, P.; CNRS, INCIA, UMR 5287, F-33400 Talence

    Purpose: Cardiac imaging suffers from both respiratory and cardiac motion. One of the proposed solutions involves double gated acquisitions. Although such an approach may lead to both respiratory and cardiac motion compensation there are issues associated with (a) the combination of data from cardiac and respiratory motion bins, and (b) poor statistical quality images as a result of using only part of the acquired data. The main objective of this work was to evaluate different schemes of combining binned data in order to identify the best strategy to reconstruct motion free cardiac images from dual gated positron emission tomography (PET)more » acquisitions. Methods: A digital phantom study as well as seven human studies were used in this evaluation. PET data were acquired in list mode (LM). A real-time position management system and an electrocardiogram device were used to provide the respiratory and cardiac motion triggers registered within the LM file. Acquired data were subsequently binned considering four and six cardiac gates, or the diastole only in combination with eight respiratory amplitude gates. PET images were corrected for attenuation, but no randoms nor scatter corrections were included. Reconstructed images from each of the bins considered above were subsequently used in combination with an affine or an elastic registration algorithm to derive transformation parameters allowing the combination of all acquired data in a particular position in the cardiac and respiratory cycles. Images were assessed in terms of signal-to-noise ratio (SNR), contrast, image profile, coefficient-of-variation (COV), and relative difference of the recovered activity concentration. Results: Regardless of the considered motion compensation strategy, the nonrigid motion model performed better than the affine model, leading to higher SNR and contrast combined with a lower COV. Nevertheless, when compensating for respiration only, no statistically significant differences were observed in the performance of the two motion models considered. Superior image SNR and contrast were seen using the affine respiratory motion model in combination with the diastole cardiac bin in comparison to the use of the whole cardiac cycle. In contrast, when simultaneously correcting for cardiac beating and respiration, the elastic respiratory motion model outperformed the affine model. In this context, four cardiac bins associated with eight respiratory amplitude bins seemed to be adequate. Conclusions: Considering the compensation of respiratory motion effects only, both affine and elastic based approaches led to an accurate resizing and positioning of the myocardium. The use of the diastolic phase combined with an affine model based respiratory motion correction may therefore be a simple approach leading to significant quality improvements in cardiac PET imaging. However, the best performance was obtained with the combined correction for both cardiac and respiratory movements considering all the dual-gated bins independently through the use of an elastic model based motion compensation.« less

  8. Low-dose computed tomography scans with automatic exposure control for patients of different ages undergoing cardiac PET/CT and SPECT/CT.

    PubMed

    Yang, Ching-Ching; Yang, Bang-Hung; Tu, Chun-Yuan; Wu, Tung-Hsin; Liu, Shu-Hsin

    2017-06-01

    This study aimed to evaluate the efficacy of automatic exposure control (AEC) in order to optimize low-dose computed tomography (CT) protocols for patients of different ages undergoing cardiac PET/CT and single-photon emission computed tomography/computed tomography (SPECT/CT). One PET/CT and one SPECT/CT were used to acquire CT images for four anthropomorphic phantoms representative of 1-year-old, 5-year-old and 10-year-old children and an adult. For the hybrid systems investigated in this study, the radiation dose and image quality of cardiac CT scans performed with AEC activated depend mainly on the selection of a predefined image quality index. Multiple linear regression methods were used to analyse image data from anthropomorphic phantom studies to investigate the effects of body size and predefined image quality index on CT radiation dose in cardiac PET/CT and SPECT/CT scans. The regression relationships have a coefficient of determination larger than 0.9, indicating a good fit to the data. According to the regression models, low-dose protocols using the AEC technique were optimized for patients of different ages. In comparison with the standard protocol with AEC activated for adult cardiac examinations used in our clinical routine practice, the optimized paediatric protocols in PET/CT allow 32.2, 63.7 and 79.2% CT dose reductions for anthropomorphic phantoms simulating 10-year-old, 5-year-old and 1-year-old children, respectively. The corresponding results for cardiac SPECT/CT are 8.4, 51.5 and 72.7%. AEC is a practical way to reduce CT radiation dose in cardiac PET/CT and SPECT/CT, but the AEC settings should be determined properly for optimal effect. Our results show that AEC does not eliminate the need for paediatric protocols and CT examinations using the AEC technique should be optimized for paediatric patients to reduce the radiation dose as low as reasonably achievable.

  9. Processing and analysis of cardiac optical mapping data obtained with potentiometric dyes

    PubMed Central

    Laughner, Jacob I.; Ng, Fu Siong; Sulkin, Matthew S.; Arthur, R. Martin

    2012-01-01

    Optical mapping has become an increasingly important tool to study cardiac electrophysiology in the past 20 years. Multiple methods are used to process and analyze cardiac optical mapping data, and no consensus currently exists regarding the optimum methods. The specific methods chosen to process optical mapping data are important because inappropriate data processing can affect the content of the data and thus alter the conclusions of the studies. Details of the different steps in processing optical imaging data, including image segmentation, spatial filtering, temporal filtering, and baseline drift removal, are provided in this review. We also provide descriptions of the common analyses performed on data obtained from cardiac optical imaging, including activation mapping, action potential duration mapping, repolarization mapping, conduction velocity measurements, and optical action potential upstroke analysis. Optical mapping is often used to study complex arrhythmias, and we also discuss dominant frequency analysis and phase mapping techniques used for the analysis of cardiac fibrillation. PMID:22821993

  10. Cardiac Magnetic Resonance Imaging in Myocarditis Reveals Persistent Disease Activity Despite Normalization of Cardiac Enzymes and Inflammatory Parameters at 3-Month Follow-Up.

    PubMed

    Berg, Jan; Kottwitz, Jan; Baltensperger, Nora; Kissel, Christine K; Lovrinovic, Marina; Mehra, Tarun; Scherff, Frank; Schmied, Christian; Templin, Christian; Lüscher, Thomas F; Heidecker, Bettina; Manka, Robert

    2017-11-01

    There is a major unmet need to identify high-risk patients in myocarditis. Although decreasing cardiac and inflammatory markers are commonly interpreted as resolving myocarditis, this assumption has not been confirmed as of today. We sought to evaluate whether routine laboratory parameters at diagnosis predict dynamic of late gadolinium enhancement (LGE) as persistent LGE has been shown to be a risk marker in myocarditis. Myocarditis was diagnosed based on clinical presentation, high-sensitivity troponin T, and cardiac magnetic resonance imaging, after exclusion of obstructive coronary artery disease by angiography. Cardiac magnetic resonance imaging was repeated at 3 months. LGE extent was analyzed with the software GT Volume. Change in LGE >20% was considered significant. Investigated cardiac and inflammatory markers included high-sensitivity troponin T, creatine kinase, myoglobin, N-terminal B-type natriuretic peptide, C-reactive protein, and leukocyte count. Twenty-four patients were enrolled. Absolute levels of cardiac enzymes and inflammatory markers at baseline did not predict change in LGE at 3 months. Cardiac and inflammatory markers had normalized in 21 patients (88%). LGE significantly improved in 16 patients (67%); however, it persisted to a lesser degree in 17 of them (71%) and increased in a small percentage (21%) despite normalization of cardiac enzymes. This is the first study reporting that cardiac enzymes and inflammatory parameters do not sufficiently reflect LGE in myocarditis. Although a majority of patients with normalizing laboratory markers experienced improved LGE, in a small percentage LGE worsened. These data suggest that cardiac magnetic resonance imaging might add value to currently existing diagnostic tools for risk assessment in myocarditis. © 2017 American Heart Association, Inc.

  11. Coi-wiz: An interactive computer wizard for analyzing cardiac optical signals.

    PubMed

    Yuan, Xiaojing; Uyanik, Ilyas; Situ, Ning; Xi, Yutao; Cheng, Jie

    2009-01-01

    A number of revolutionary techniques have been developed for cardiac electrophysiology research to better study the various arrhythmia mechanisms that can enhance ablating strategies for cardiac arrhythmias. Once the three-dimensional high resolution cardiac optical imaging data is acquired, it is time consuming to manually go through them and try to identify the patterns associated with various arrhythmia symptoms. In this paper, we present an interactive computer wizard that helps cardiac electrophysiology researchers to visualize and analyze the high resolution cardiac optical imaging data. The wizard provides a file interface that accommodates different file formats. A series of analysis algorithms output waveforms, activation and action potential maps after spatial and temporal filtering, velocity field and heterogeneity measure. The interactive GUI allows the researcher to identify the region of interest in both the spatial and temporal domain, thus enabling them to study different heart chamber at their choice.

  12. In vivo high-resolution structural imaging of large arteries in small rodents using two-photon laser scanning microscopy

    NASA Astrophysics Data System (ADS)

    Megens, Remco T. A.; Reitsma, Sietze; Prinzen, Lenneke; Oude Egbrink, Mirjam G. A.; Engels, Wim; Leenders, Peter J. A.; Brunenberg, Ellen J. L.; Reesink, Koen D.; Janssen, Ben J. A.; Ter Haar Romeny, Bart M.; Slaaf, Dick W.; van Zandvoort, Marc A. M. J.

    2010-01-01

    In vivo (molecular) imaging of the vessel wall of large arteries at subcellular resolution is crucial for unraveling vascular pathophysiology. We previously showed the applicability of two-photon laser scanning microscopy (TPLSM) in mounted arteries ex vivo. However, in vivo TPLSM has thus far suffered from in-frame and between-frame motion artifacts due to arterial movement with cardiac and respiratory activity. Now, motion artifacts are suppressed by accelerated image acquisition triggered on cardiac and respiratory activity. In vivo TPLSM is performed on rat renal and mouse carotid arteries, both surgically exposed and labeled fluorescently (cell nuclei, elastin, and collagen). The use of short acquisition times consistently limit in-frame motion artifacts. Additionally, triggered imaging reduces between-frame artifacts. Indeed, structures in the vessel wall (cell nuclei, elastic laminae) can be imaged at subcellular resolution. In mechanically damaged carotid arteries, even the subendothelial collagen sheet (~1 μm) is visualized using collagen-targeted quantum dots. We demonstrate stable in vivo imaging of large arteries at subcellular resolution using TPLSM triggered on cardiac and respiratory cycles. This creates great opportunities for studying (diseased) arteries in vivo or immediate validation of in vivo molecular imaging techniques such as magnetic resonance imaging (MRI), ultrasound, and positron emission tomography (PET).

  13. Fast automatic delineation of cardiac volume of interest in MSCT images

    NASA Astrophysics Data System (ADS)

    Lorenz, Cristian; Lessick, Jonathan; Lavi, Guy; Bulow, Thomas; Renisch, Steffen

    2004-05-01

    Computed Tomography Angiography (CTA) is an emerging modality for assessing cardiac anatomy. The delineation of the cardiac volume of interest (VOI) is a pre-processing step for subsequent visualization or image processing. It serves the suppression of anatomic structures being not in the primary focus of the cardiac application, such as sternum, ribs, spinal column, descending aorta and pulmonary vasculature. These structures obliterate standard visualizations such as direct volume renderings or maximum intensity projections. In addition, outcome and performance of post-processing steps such as ventricle suppression, coronary artery segmentation or the detection of short and long axes of the heart can be improved. The structures being part of the cardiac VOI (coronary arteries and veins, myocardium, ventricles and atria) differ tremendously in appearance. In addition, there is no clear image feature associated with the contour (or better cut-surface) distinguishing between cardiac VOI and surrounding tissue making the automatic delineation of the cardiac VOI a difficult task. The presented approach locates in a first step chest wall and descending aorta in all image slices giving a rough estimate of the location of the heart. In a second step, a Fourier based active contour approach delineates slice-wise the border of the cardiac VOI. The algorithm has been evaluated on 41 multi-slice CT data-sets including cases with coronary stents and venous and arterial bypasses. The typical processing time amounts to 5-10s on a 1GHz P3 PC.

  14. The effects of nuclear magnetic resonance on patients with cardiac pacemakers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pavlicek, W.; Geisinger, M.; Castle, L.

    1983-04-01

    The effect of nuclear magnetic resonance (NMR) imaging on six representative cardiac pacemakers was studied. The results indicate that the threshold for initiating the asynchronous mode of a pacemaker is 17 gauss. Radiofrequency levels are present in an NMR unit and may confuse or possibly inhibit demand pacemakers, although sensing circuitry is normally provided with electromagnetic interference discrimination. Time-varying magnetic fields can generate pulse amplitudes and frequencies to mimic cardiac activity. A serious limitation in the possibility of imaging a patient with a pacemaker would be the alteration of normal pulsing parameters due to time-varying magnetic fields.

  15. The way to a man's heart is through his stomach: much 'diaphragmatic' attenuation is likely gastric, and effervescent granules enhance cardiac imaging.

    PubMed

    Munn, Samson

    2004-12-01

    Avoidance of falsely positive results depends on distinguishing reality from artifact, in turn depending on images of highest quality. In radionuclide cardiac imaging, an inferior wall artifactual defect, so called "diaphragmatic attenuation", is particularly common and vexing. Despite the historically held view, analysis and review of the literature suggest the defect is likely not diaphragmatic but rather primarily due to attenuation by nearby stomach wall. The explanation is based on gravity and anatomy. With this improved understanding, effervescent granules were given as a clinical, nonresearch measure to nine patients during myocardial scanning. It was observed that two-thirds demonstrated moderate or marked lessening of attenuation. An additional benefit is lessening of artifact by extracardiac activity. These benefits may also apply to other sorts of cardiac radionuclide imaging. The significance of this new imaging method is discussed and various avenues of research are proposed.

  16. Cardiac sarcoidosis: challenges in clinical practice.

    PubMed

    Bakker, Anne L; Grutters, Jan C; Keijsers, Ruth G; Post, Martijn C

    2017-09-01

    To address the current recommendations for screening, diagnosis, and treatment of cardiac sarcoidosis and the difficulties to put these recommendations into clinical practice. The incidence of cardiac sarcoidosis appears to be higher than earlier reported, probably because of improved imaging techniques. Late gadolinium enhancement with cardiac MRI (LGE-CMR) and fluorodeoxyglucose positron emission tomography obtained a central role in the diagnostic algorithm and monitoring of disease activity. New techniques are being investigated: T1 and T2 mapping for early detection in CMR, a sarcoid-specific tracer in PET, integrated positron emission tomography/MRI scanners, and assessment of scar with LGE in cardiac computed tomography. Isolated cardiac sarcoidosis is an increasingly recognized phenotype, but still an enormous challenge in clinical practice. The prognostic value of (and extent of) LGE-CMR should be taken into account for risk assessment and internal cardiac defbrillator therapy, even in patients with preserved left ventricular function. Unfortunately, randomized controlled trials to guide immunosuppressive therapy are still lacking. A multidisciplinary approach to diagnose and treat cardiac sarcoidosis patients in specialized centers is strongly recommendable. Cardiac sarcoidosis is increasingly recognized because of improved imaging techniques; however, treatment of cardiac sarcoidosis is still mainly based on expert opinion.

  17. Biomarkers and Imaging Findings of Anderson–Fabry Disease—What We Know Now

    PubMed Central

    Beirão, Idalina; Cabrita, Ana; Torres, Márcia; Silva, Fernando; Aguiar, Patrício; Laranjeira, Francisco; Gomes, Ana Marta

    2017-01-01

    Anderson–Fabry disease (AFD) is an X-linked lysosomal storage disorder, caused by deficiency or absence of the alpha-galactosidase A activity, with a consequent glycosphingolipid accumulation. Biomarkers and imaging findings may be useful for diagnosis, identification of an organ involvement, therapy monitoring and prognosis. The aim of this article is to review the current available literature on biomarkers and imaging findings of AFD patients. An extensive bibliographic review from PubMed, Medline and Clinical Key databases was performed by a group of experts from nephrology, neurology, genetics, cardiology and internal medicine, aiming for consensus. Lyso-GB3 is a valuable biomarker to establish the diagnosis. Proteinuria and creatinine are the most valuable to detect renal damage. Troponin I and high-sensitivity assays for cardiac troponin T can identify patients with cardiac lesions, but new techniques of cardiac imaging are essential to detect incipient damage. Specific cerebrovascular imaging findings are present in AFD patients. Techniques as metabolomics and proteomics have been developed in order to find an AFD fingerprint. Lyso-GB3 is important for evaluating the pathogenic mutations and monitoring the response to treatment. Many biomarkers can detect renal, cardiac and cerebrovascular involvement, but none of these have proved to be important to monitoring the response to treatment. Imaging features are preferred in order to find cardiac and cerebrovascular compromise in AFD patients. PMID:28933368

  18. A novel dual gating approach using joint inertial sensors: implications for cardiac PET imaging

    NASA Astrophysics Data System (ADS)

    Jafari Tadi, Mojtaba; Teuho, Jarmo; Lehtonen, Eero; Saraste, Antti; Pänkäälä, Mikko; Koivisto, Tero; Teräs, Mika

    2017-10-01

    Positron emission tomography (PET) is a non-invasive imaging technique which may be considered as the state of art for the examination of cardiac inflammation due to atherosclerosis. A fundamental limitation of PET is that cardiac and respiratory motions reduce the quality of the achieved images. Current approaches for motion compensation involve gating the PET data based on the timing of quiescent periods of cardiac and respiratory cycles. In this study, we present a novel gating method called microelectromechanical (MEMS) dual gating which relies on joint non-electrical sensors, i.e. tri-axial accelerometer and gyroscope. This approach can be used for optimized selection of quiescent phases of cardiac and respiratory cycles. Cardiomechanical activity according to echocardiography observations was investigated to confirm whether this dual sensor solution can provide accurate trigger timings for cardiac gating. Additionally, longitudinal chest motions originating from breathing were measured by accelerometric- and gyroscopic-derived respiratory (ADR and GDR) tracking. The ADR and GDR signals were evaluated against Varian real-time position management (RPM) signals in terms of amplitude and phase. Accordingly, high linear correlation and agreement were achieved between the reference electrocardiography, RPM, and measured MEMS signals. We also performed a Ge-68 phantom study to evaluate possible metal artifacts caused by the integrated read-out electronics including mechanical sensors and semiconductors. The reconstructed phantom images did not reveal any image artifacts. Thus, it was concluded that MEMS-driven dual gating can be used in PET studies without an effect on the quantitative or visual accuracy of the PET images. Finally, the applicability of MEMS dual gating for cardiac PET imaging was investigated with two atherosclerosis patients. Dual gated PET images were successfully reconstructed using only MEMS signals and both qualitative and quantitative assessments revealed encouraging results that warrant further investigation of this method.

  19. Ga-67 cardiac uptake

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, D.S.; Tipton, R.E.

    1983-12-01

    A case of positive Ga-67 image due to tuberculous pericarditis is presented. The pattern and distribution of the uptake suggested that the concentration of the activity was mainly in the inflamed pericardium. The known causes of Ga-67 cardiac uptake were reviewed, and a differential diagnosis is given.

  20. Targeted Nuclear Imaging Probes for Cardiac Amyloidosis.

    PubMed

    Bravo, Paco E; Dorbala, Sharmila

    2017-07-01

    The aim of the present manuscript is to review the latest advancements of radionuclide molecular imaging in the diagnosis and prognosis of individuals with cardiac amyloidosis. 99m Technetium labeled bone tracer scintigraphy had been known to image cardiac amyloidosis, since the 1980s; over the past decade, bone scintigraphy has been revived specifically to diagnose transthyretin cardiac amyloidosis. 18 F labeled and 11 C labeled amyloid binding radiotracers developed for imaging Alzheimer's disease, have been repurposed since 2013, to image light chain and transthyretin cardiac amyloidosis. 99m Technetium bone scintigraphy for transthyretin cardiac amyloidosis, and amyloid binding targeted PET imaging for light chain and transthyretin cardiac amyloidosis, are emerging as highly accurate methods. Targeted radionuclide imaging may soon replace endomyocardial biopsy in the evaluation of patients with suspected cardiac amyloidosis. Further research is warranted on the role of targeted imaging to quantify cardiac amyloidosis and to guide therapy.

  1. Comparative Analysis of Telomerase Activity in CD117⁺ CD34⁺ Cardiac Telocytes with Bone Mesenchymal Stem Cells, Cardiac Fibroblasts and Cardiomyocytes.

    PubMed

    Li, Yuan-Yuan; Lu, Shan-Shan; Xu, Ting; Zhang, Hong-Qi; Li, Hua

    2015-07-20

    This study characterized the cardiac telocyte (TC) population both in vivo and in vitro, and investigated its telomerase activity related to mitosis. Using transmission electron microscopy and a phase contrast microscope, the typical morphological features of cardiac TCs were observed; by targeting the cell surface proteins CD117 and CD34, CD117 + CD34 + cardiac TCs were sorted via flow cytometry and validated by immunofluorescence based on the primary cell culture. Then the optimized basal nutrient medium for selected population was examined with the cell counting kit 8. Under this conditioned medium, the process of cell division was captured, and the telomerase activity of CD117 + CD34 + cardiac TCs was detected in comparison with bone mesenchymal stem cells (BMSCs), cardiac fibroblasts (CFBs), cardiomyocytes (CMs). Cardiac TCs projected characteristic telopodes with thin segments (podomers) in alternation with dilation (podoms). In addition, 64% of the primary cultured cardiac TCs were composed of CD117 + CD34 + cardiac TCs; which was verified by immunofluorescence. In a live cell imaging system, CD117 + CD34 + cardiac TCs were observed to enter into cell division in a short time, followed by an significant invagination forming across the middle of the cell body. Using a real-time quantitative telomeric-repeat amplification assay, the telomerase concentration in CD117 + CD34 + cardiac TCs was obviously lower than in BMSCs and CFBs, and significantly higher than in CMs. Cardiac TCs represent a unique cell population and CD117 + CD34 + cardiac TCs have relative low telomerase activity that differs from BMSCs, CFBs and CMs and thus they might play an important role in maintaining cardiac homeostasis.

  2. Phantom studies investigating extravascular density imaging for partial volume correction of 3-D PET /sup 18/FDG studies

    NASA Astrophysics Data System (ADS)

    Wassenaar, R. W.; Beanlands, R. S. B.; deKemp, R. A.

    2004-02-01

    Limited scanner resolution and cardiac motion contribute to partial volume (PV) averaging of cardiac PET images. An extravascular (EV) density image, created from the subtraction of a blood pool scan from a transmission image, has been used to correct for PV averaging in H/sub 2//sup 15/O studies using 2-D imaging but not with 3-D imaging of other tracers such as /sup 18/FDG. A cardiac phantom emulating the left ventricle was used to characterize the method for use in 3-D PET studies. Measurement of the average myocardial activity showed PV losses of 32% below the true activity (p<0.001). Initial application of the EV density correction still yielded a myocardial activity 13% below the true value (p<0.001). This failure of the EV density image was due to the 1.66 mm thick plastic barrier separating the myocardial and ventricular chambers within the phantom. Upon removal of this artifact by morphological dilation of the blood pool, the corrected myocardial value was within 2% of the true value (p=ns). Spherical ROIs (diameter of 2 to 10 mm), evenly distributed about the myocardium, were also used to calculate the average activity. The EV density image was able to account for PV averaging throughout the range of diameters to within a 5% accuracy, however, a small bias was seen as the size of the ROIs increased. This indicated a slight mismatch between the emission and transmission image resolutions, a result of the difference in data acquisitions (i.e., span and ring difference) and default smoothing. These results show that the use of EV density image to correct for PV averaging is possible with 3-D PET. A method of correcting barrier effects in phantoms has been presented, as well as a process for evaluating resolution mismatch.

  3. Perspectives on Current Training Guidelines for Cardiac Imaging and Recommendations for the Future.

    PubMed

    Arrighi, James A; Kilic, Sena; Haines, Philip G

    2018-04-23

    To summarize current training guidelines for cardiac imaging and provide recommendations for future guidelines. The current structure of training in cardiac imaging is largely dictated by modality-specific guidelines. While there has been debate on how to define the advanced cardiac imager for over a decade, a uniform consensus has not emerged. We report the perspectives of three key stakeholders in this debate: a senior faculty member-former fellowship program director, a cardiology fellow, and an academic junior faculty imaging expert. The observations of these stakeholders suggest that there is no consensus on the definition of advanced cardiac imaging, leading to ambiguity in training guidelines. This may have negative impact on recruitment of fellows into cardiac imaging careers. Based on the current status of training in cardiac imaging, the authors suggest that the relevant professional groups reconvene to form a consensus in defining advanced cardiac imaging, in order to guide future revisions of training guidelines.

  4. Physics of cardiac imaging with multiple-row detector CT.

    PubMed

    Mahesh, Mahadevappa; Cody, Dianna D

    2007-01-01

    Cardiac imaging with multiple-row detector computed tomography (CT) has become possible due to rapid advances in CT technologies. Images with high temporal and spatial resolution can be obtained with multiple-row detector CT scanners; however, the radiation dose associated with cardiac imaging is high. Understanding the physics of cardiac imaging with multiple-row detector CT scanners allows optimization of cardiac CT protocols in terms of image quality and radiation dose. Knowledge of the trade-offs between various scan parameters that affect image quality--such as temporal resolution, spatial resolution, and pitch--is the key to optimized cardiac CT protocols, which can minimize the radiation risks associated with these studies. Factors affecting temporal resolution include gantry rotation time, acquisition mode, and reconstruction method; factors affecting spatial resolution include detector size and reconstruction interval. Cardiac CT has the potential to become a reliable tool for noninvasive diagnosis and prevention of cardiac and coronary artery disease. (c) RSNA, 2007.

  5. Comparison among Reconstruction Algorithms for Quantitative Analysis of 11C-Acetate Cardiac PET Imaging.

    PubMed

    Shi, Ximin; Li, Nan; Ding, Haiyan; Dang, Yonghong; Hu, Guilan; Liu, Shuai; Cui, Jie; Zhang, Yue; Li, Fang; Zhang, Hui; Huo, Li

    2018-01-01

    Kinetic modeling of dynamic 11 C-acetate PET imaging provides quantitative information for myocardium assessment. The quality and quantitation of PET images are known to be dependent on PET reconstruction methods. This study aims to investigate the impacts of reconstruction algorithms on the quantitative analysis of dynamic 11 C-acetate cardiac PET imaging. Suspected alcoholic cardiomyopathy patients ( N = 24) underwent 11 C-acetate dynamic PET imaging after low dose CT scan. PET images were reconstructed using four algorithms: filtered backprojection (FBP), ordered subsets expectation maximization (OSEM), OSEM with time-of-flight (TOF), and OSEM with both time-of-flight and point-spread-function (TPSF). Standardized uptake values (SUVs) at different time points were compared among images reconstructed using the four algorithms. Time-activity curves (TACs) in myocardium and blood pools of ventricles were generated from the dynamic image series. Kinetic parameters K 1 and k 2 were derived using a 1-tissue-compartment model for kinetic modeling of cardiac flow from 11 C-acetate PET images. Significant image quality improvement was found in the images reconstructed using iterative OSEM-type algorithms (OSME, TOF, and TPSF) compared with FBP. However, no statistical differences in SUVs were observed among the four reconstruction methods at the selected time points. Kinetic parameters K 1 and k 2 also exhibited no statistical difference among the four reconstruction algorithms in terms of mean value and standard deviation. However, for the correlation analysis, OSEM reconstruction presented relatively higher residual in correlation with FBP reconstruction compared with TOF and TPSF reconstruction, and TOF and TPSF reconstruction were highly correlated with each other. All the tested reconstruction algorithms performed similarly for quantitative analysis of 11 C-acetate cardiac PET imaging. TOF and TPSF yielded highly consistent kinetic parameter results with superior image quality compared with FBP. OSEM was relatively less reliable. Both TOF and TPSF were recommended for cardiac 11 C-acetate kinetic analysis.

  6. Enterogastroesophageal reflux detected on 99m-technetium sestamibi cardiac imaging as a cause of chest pain

    PubMed Central

    Erdoğan, Zeynep; Silov, Güler; Özdal, Ayşegül; Turhal, Özgül

    2013-01-01

    Myocardial perfusion imaging (MPI) with technetium-99m sestamibi (Tc-99m MIBI) is considered a diagnostic technique that is widely used for the investigation of suspected coronary artery disease. Incidental inspection of an extracardiac activity is indirect, but important marker, which can identify a potentially treatable non-coronary cause for chest pain that may mimic cardiac symptoms. Here, we present an illustrative case in which significant enterogastroesophageal reflux of Tc-99m MIBI occurred during the cardiac imaging following prompt hepatobiliary clearance. Because, there was normal myocardial perfusion on MPI, presence of gastroesophageal reflux (GER) on GER scintigraphy and detection of mild inflammation with pathologically confirmed hyperplastic polyp by endoscopy, in view of the above findings we concluded that the probable cause of chest pain was reflux. PMID:24019679

  7. Feasibility of myocardial PET imaging using a benzylguanidine analog: meta-(3-[18F]fluoropropyl)benzylguanidine ([18F]mFPBG).

    PubMed

    Woo, Sang-Keun; Moon, Byung Seok; Kim, Bom Sahn; Kim, Min Hwan; Lee, Yong Jin; Jung, Jae Ho; Lee, Kyo Chul; Seo, Youngho; Kim, Wook; Lim, Sang Moo; Lee, Byung Chul; Kim, Sang Eun

    2018-05-03

    Global and regional sympathetic activity in the heart can be evaluated using [ 123 I]meta-iodobenzylguanidine ([ 123 I]mIBG) imaging. However, [ 123 I]mIBG is associated with low image spatial resolution and sensitivity in cardiac imaging. We investigated the capability of an F-18-labeled mIBG derivative, meta-(3-[ 18 F]fluoropropyl)benzylguanidine ([ 18 F]mFPBG), for identifying ischemic and viable myocardium in a rat model of myocardial infarction. The ex vivo biodistribution and in vivo metabolic stability of [ 18 F]mFPBG were investigated in Sprague-Dawley rats. Selective cardiac adrenergic activation was confirmed via a blocking experiment involving pretreatment with desipramine (2 mg kg -1 ), followed by the administration of [ 18 F]mFPBG. Imaging properties of [ 18 F]mFPBG were compared with those of traditional cardiac imaging radiotracers ([ 123 I]mIBG and [ 99m Tc]MIBI) in a rat model of myocardial infarction. Non-invasive image-based measurements of infarct sizes were then compared with histological findings by using Bland-Altman analysis. The differences in infarct sizes determined using histological analysis and [ 18 F]mFPBG PET were -2.55 ± 4.99% (range: -12.33 to 7.22), -2.35 ± 3.32% (range: -8.87 to 4.16), and -3.15 ± 6.16% (range: -15.24 to 8.93) at 5, 20, and 40 min, respectively. Furthermore, [ 18 F]mFPBG PET was superior to traditional imaging methods in assessing the degree of ischemia in areas of myocardial infarction, as well as the actual infarct size. Compared to [ 123 I]mIBG, [ 18 F]mFPBG showed improved spatial resolution and sensitivity in a rat model of myocardial infarction. This result suggested that [ 18 F]mFPBG is a promising cardiac PET imaging agent for potential diagnostic application in PET cardiology. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Real-time magnetic resonance-guided ablation of typical right atrial flutter using a combination of active catheter tracking and passive catheter visualization in man: initial results from a consecutive patient series.

    PubMed

    Hilbert, Sebastian; Sommer, Philipp; Gutberlet, Matthias; Gaspar, Thomas; Foldyna, Borek; Piorkowski, Christopher; Weiss, Steffen; Lloyd, Thomas; Schnackenburg, Bernhard; Krueger, Sascha; Fleiter, Christian; Paetsch, Ingo; Jahnke, Cosima; Hindricks, Gerhard; Grothoff, Matthias

    2016-04-01

    Recently cardiac magnetic resonance (CMR) imaging has been found feasible for the visualization of the underlying substrate for cardiac arrhythmias as well as for the visualization of cardiac catheters for diagnostic and ablation procedures. Real-time CMR-guided cavotricuspid isthmus ablation was performed in a series of six patients using a combination of active catheter tracking and catheter visualization using real-time MR imaging. Cardiac magnetic resonance utilizing a 1.5 T system was performed in patients under deep propofol sedation. A three-dimensional-whole-heart sequence with navigator technique and a fast automated segmentation algorithm was used for online segmentation of all cardiac chambers, which were thereafter displayed on a dedicated image guidance platform. In three out of six patients complete isthmus block could be achieved in the MR scanner, two of these patients did not need any additional fluoroscopy. In the first patient technical issues called for a completion of the procedure in a conventional laboratory, in another two patients the isthmus was partially blocked by magnetic resonance imaging (MRI)-guided ablation. The mean procedural time for the MR procedure was 109 ± 58 min. The intubation of the CS was performed within a mean time of 2.75 ± 2.21 min. Total fluoroscopy time for completion of the isthmus block ranged from 0 to 7.5 min. The combination of active catheter tracking and passive real-time visualization in CMR-guided electrophysiologic (EP) studies using advanced interventional hardware and software was safe and enabled efficient navigation, mapping, and ablation. These cases demonstrate significant progress in the development of MR-guided EP procedures. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  9. ASCI 2010 contrast media guideline for cardiac imaging: a report of the Asian Society of Cardiovascular Imaging cardiac computed tomography and cardiac magnetic resonance imaging guideline working group.

    PubMed

    Jinzaki, Masahiro; Kitagawa, Kakuya; Tsai, I-Chen; Chan, Carmen; Yu, Wei; Yong, Hwan Seok; Choi, Byoung Wook

    2010-12-01

    The use of contrast media for cardiac imaging becomes increasing as the widespread of cardiac CT and cardiac MR. A radiologist needs to carefully consider the indication and the injection protocol of contrast media to be used as well as the possibility of adverse effect. There are several guidelines for contrast media in western countries. However, these are focusing the adverse effect of contrast media. The Asian Society of Cardiovascular Imaging, the only society dedicated to cardiovascular imaging in Asia, formed a Working Group and created a guideline, which summarizes the integrated knowledge of contrast media for cardiac imaging. In cardiac imaging, coronary artery evaluation is feasible by non-contrast MR angiography, which can be an alternative examination in high risk patients for the use of iodine contrast media. Furthermore, the body habitus of Asian patients is usually smaller than that of their western counterparts. This necessitates modifications in the injection protocol and in the formula for calculation of estimated glomerular filtration rate. This guideline provided fundamental information for the use of contrast media for Asian patients in cardiac imaging.

  10. ASCI 2010 contrast media guideline for cardiac imaging: a report of the Asian Society of Cardiovascular Imaging cardiac computed tomography and cardiac magnetic resonance imaging guideline working group

    PubMed Central

    Kitagawa, Kakuya; Tsai, I-Chen; Chan, Carmen; Yu, Wei; Yong, Hwan Seok; Choi, Byoung Wook

    2010-01-01

    The use of contrast media for cardiac imaging becomes increasing as the widespread of cardiac CT and cardiac MR. A radiologist needs to carefully consider the indication and the injection protocol of contrast media to be used as well as the possibility of adverse effect. There are several guidelines for contrast media in western countries. However, these are focusing the adverse effect of contrast media. The Asian Society of Cardiovascular Imaging, the only society dedicated to cardiovascular imaging in Asia, formed a Working Group and created a guideline, which summarizes the integrated knowledge of contrast media for cardiac imaging. In cardiac imaging, coronary artery evaluation is feasible by non-contrast MR angiography, which can be an alternative examination in high risk patients for the use of iodine contrast media. Furthermore, the body habitus of Asian patients is usually smaller than that of their western counterparts. This necessitates modifications in the injection protocol and in the formula for calculation of estimated glomerular filtration rate. This guideline provided fundamental information for the use of contrast media for Asian patients in cardiac imaging. PMID:20931289

  11. In vivo cardiac nano-imaging: A new technology for high-precision analyses of sarcomere dynamics in the heart.

    PubMed

    Shimozawa, Togo; Hirokawa, Erisa; Kobirumaki-Shimozawa, Fuyu; Oyama, Kotaro; Shintani, Seine A; Terui, Takako; Kushida, Yasuharu; Tsukamoto, Seiichi; Fujii, Teruyuki; Ishiwata, Shin'ichi; Fukuda, Norio

    2017-03-01

    The cardiac pump function is a result of a rise in intracellular Ca 2+ and the ensuing sarcomeric contractions [i.e., excitation-contraction (EC) coupling] in myocytes in various locations of the heart. In order to elucidate the heart's mechanical properties under various settings, cardiac imaging is widely performed in today's clinical as well as experimental cardiology by using echocardiogram, magnetic resonance imaging and computed tomography. However, because these common techniques detect local myocardial movements at a spatial resolution of ∼100 μm, our knowledge on the sub-cellular mechanisms of the physiology and pathophysiology of the heart in vivo is limited. This is because (1) EC coupling occurs in the μm partition in a myocyte and (2) cardiac sarcomeres generate active force upon a length change of ∼100 nm on a beat-to-beat basis. Recent advances in optical technologies have enabled measurements of intracellular Ca 2+ dynamics and sarcomere length displacements at high spatial and temporal resolution in the beating heart of living rodents. Future studies with these technologies are warranted to open a new era in cardiac research. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Reduced cardiac vagal activity in obese children and adolescents.

    PubMed

    Dangardt, Frida; Volkmann, Reinhard; Chen, Yun; Osika, Walter; Mårild, Staffan; Friberg, Peter

    2011-03-01

      Obese children present with various cardiovascular risk factors affecting their future health. In adults, cardiac autonomic function is a major risk factor, predicting cardiovascular morbidity and mortality. We hypothesized that obese children and adolescents had a lower cardiac vagal activity than lean subjects. We measured cardiac spontaneous baroreflex sensitivity (BRS), reflecting the dynamic regulation of cardiac vagal function, in large groups of obese and lean young individuals.   Cardiac BRS, using the sequence approach, was assessed in 120 obese (59 girls), 43 overweight (23 girls) and 148 lean subjects (78 girls). Obese subjects showed a decreased BRS compared to both overweight and lean subjects [16±7 versus 21±9 (P<0·01) and 22±10 ms per mmHg (P<0·0001), respectively]. The differences remained after correcting for age, gender and pubertal status.   Children with obesity had low vagal activity at rest, and there was no gender difference. © 2010 The Authors. Clinical Physiology and Functional Imaging © 2010 Scandinavian Society of Clinical Physiology and Nuclear Medicine.

  13. Electrical and Structural Substrate of Arrhythmogenic Right Ventricular Cardiomyopathy Determined Using Noninvasive Electrocardiographic Imaging and Late Gadolinium Magnetic Resonance Imaging.

    PubMed

    Andrews, Christopher M; Srinivasan, Neil T; Rosmini, Stefania; Bulluck, Heerajnarain; Orini, Michele; Jenkins, Sharon; Pantazis, Antonis; McKenna, William J; Moon, James C; Lambiase, Pier D; Rudy, Yoram

    2017-07-01

    Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a significant cause of sudden cardiac death in the young. Improved noninvasive assessment of ARVC and better understanding of the disease substrate are important for improving patient outcomes. We studied 20 genotyped ARVC patients with a broad spectrum of disease using electrocardiographic imaging (a method for noninvasive cardiac electrophysiology mapping) and advanced late gadolinium enhancement cardiac magnetic resonance scar imaging. Compared with 20 healthy controls, ARVC patients had longer ventricular activation duration (median, 52 versus 42 ms; P =0.007) and prolonged mean epicardial activation-recovery intervals (a surrogate for local action potential duration; median, 275 versus 241 ms; P =0.014). In these patients, we observed abnormal and varied epicardial activation breakthrough locations and regions of nonuniform conduction and fractionated electrograms. Nonuniform conduction and fractionated electrograms were present in the early concealed phase of ARVC. Electrophysiological abnormalities colocalized with late gadolinium enhancement scar, indicating a relationship with structural disease. Premature ventricular contractions were common in ARVC patients with variable initiation sites in both ventricles. Premature ventricular contraction rate increased with exercise, and within anatomic segments, it correlated with prolonged repolarization, electric markers of scar, and late gadolinium enhancement (all P <0.001). Electrocardiographic imaging reveals electrophysiological substrate properties that differ in ARVC patients compared with healthy controls. A novel mechanistic finding is the presence of repolarization abnormalities in regions where ventricular ectopy originates. The results suggest a potential role for electrocardiographic imaging and late gadolinium enhancement in early diagnosis and noninvasive follow-up of ARVC patients. © 2017 American Heart Association, Inc.

  14. New horizons in cardiac innervation imaging: introduction of novel 18F-labeled PET tracers.

    PubMed

    Kobayashi, Ryohei; Chen, Xinyu; Werner, Rudolf A; Lapa, Constantin; Javadi, Mehrbod S; Higuchi, Takahiro

    2017-12-01

    Cardiac sympathetic nervous activity can be uniquely visualized by non-invasive radionuclide imaging techniques due to the fast growing and widespread application of nuclear cardiology in the last few years. The norepinephrine analogue 123 I-meta-iodobenzylguanidine ( 123 I-MIBG) is a single photon emission computed tomography (SPECT) tracer for the clinical implementation of sympathetic nervous imaging for both diagnosis and prognosis of heart failure. Meanwhile, positron emission tomography (PET) imaging has become increasingly attractive because of its higher spatial and temporal resolution compared to SPECT, which allows regional functional and dynamic kinetic analysis. Nevertheless, wider use of cardiac sympathetic nervous PET imaging is still limited mainly due to the demand of costly on-site cyclotrons, which are required for the production of conventional 11 C-labeled (radiological half-life, 20 min) PET tracers. Most recently, more promising 18 F-labeled (half-life, 110 min) PET radiopharmaceuticals targeting sympathetic nervous system have been introduced. These tracers optimize PET imaging and, by using delivery networks, cost less to produce. In this article, the latest advances of sympathetic nervous imaging using 18 F-labeled radiotracers along with their possible applications are reviewed.

  15. Automated motion artifact removal for intravital microscopy, without a priori information.

    PubMed

    Lee, Sungon; Vinegoni, Claudio; Sebas, Matthew; Weissleder, Ralph

    2014-03-28

    Intravital fluorescence microscopy, through extended penetration depth and imaging resolution, provides the ability to image at cellular and subcellular resolution in live animals, presenting an opportunity for new insights into in vivo biology. Unfortunately, physiological induced motion components due to respiration and cardiac activity are major sources of image artifacts and impose severe limitations on the effective imaging resolution that can be ultimately achieved in vivo. Here we present a novel imaging methodology capable of automatically removing motion artifacts during intravital microscopy imaging of organs and orthotopic tumors. The method is universally applicable to different laser scanning modalities including confocal and multiphoton microscopy, and offers artifact free reconstructions independent of the physiological motion source and imaged organ. The methodology, which is based on raw data acquisition followed by image processing, is here demonstrated for both cardiac and respiratory motion compensation in mice heart, kidney, liver, pancreas and dorsal window chamber.

  16. Automated motion artifact removal for intravital microscopy, without a priori information

    PubMed Central

    Lee, Sungon; Vinegoni, Claudio; Sebas, Matthew; Weissleder, Ralph

    2014-01-01

    Intravital fluorescence microscopy, through extended penetration depth and imaging resolution, provides the ability to image at cellular and subcellular resolution in live animals, presenting an opportunity for new insights into in vivo biology. Unfortunately, physiological induced motion components due to respiration and cardiac activity are major sources of image artifacts and impose severe limitations on the effective imaging resolution that can be ultimately achieved in vivo. Here we present a novel imaging methodology capable of automatically removing motion artifacts during intravital microscopy imaging of organs and orthotopic tumors. The method is universally applicable to different laser scanning modalities including confocal and multiphoton microscopy, and offers artifact free reconstructions independent of the physiological motion source and imaged organ. The methodology, which is based on raw data acquisition followed by image processing, is here demonstrated for both cardiac and respiratory motion compensation in mice heart, kidney, liver, pancreas and dorsal window chamber. PMID:24676021

  17. ACTIVE DELIVERY CABLE TUNED TO DEVICE DEPLOYMENT STATE: ENHANCED VISIBILITY OF NITINOL OCCLUDERS DURING PRE-CLINICAL INTERVENTIONAL MRI

    PubMed Central

    Bell, Jamie A.; Saikus, Christina E.; Ratnayaka, Kanishka; Barbash, Israel M.; Faranesh, Anthony Z.; Franson, Dominique N.; Sonmez, Merdim; Slack, Michael C.; Lederman, Robert J.; Kocaturk, Ozgur

    2012-01-01

    Purpose To develop an active delivery system that enhances visualization of nitinol cardiac occluder devices during deployment under real-time MRI. Materials and Methods We constructed an active delivery cable incorporating a loopless antenna and a custom titanium microscrew to secure the occluder devices. The delivery cable was tuned and matched to 50Ω at 64 MHz with the occluder device attached. We used real-time balanced SSFP in a wide-bore 1.5T scanner. Device-related images were reconstructed separately and combined with surface-coil images. The delivery cable was tested in vitro in a phantom and in vivo in swine using a variety of nitinol cardiac occluder devices. Results In vitro, the active delivery cable provided little signal when the occluder device was detached and maximal signal with the device attached. In vivo, signal from the active delivery cable enabled clear visualization of occluder device during positioning and deployment. Device release resulted in decreased signal from the active cable. Post-mortem examination confirmed proper device placement. Conclusions The active delivery cable enhanced the MRI depiction of nitinol cardiac occluder devices during positioning and deployment, both in conventional and novel applications. We expect enhanced visibility to contribute to effectiveness and safety of new and emerging MRI-guided treatments. PMID:22707441

  18. Cardiac macrophages promote diastolic dysfunction.

    PubMed

    Hulsmans, Maarten; Sager, Hendrik B; Roh, Jason D; Valero-Muñoz, María; Houstis, Nicholas E; Iwamoto, Yoshiko; Sun, Yuan; Wilson, Richard M; Wojtkiewicz, Gregory; Tricot, Benoit; Osborne, Michael T; Hung, Judy; Vinegoni, Claudio; Naxerova, Kamila; Sosnovik, David E; Zile, Michael R; Bradshaw, Amy D; Liao, Ronglih; Tawakol, Ahmed; Weissleder, Ralph; Rosenzweig, Anthony; Swirski, Filip K; Sam, Flora; Nahrendorf, Matthias

    2018-02-05

    Macrophages populate the healthy myocardium and, depending on their phenotype, may contribute to tissue homeostasis or disease. Their origin and role in diastolic dysfunction, a hallmark of cardiac aging and heart failure with preserved ejection fraction, remain unclear. Here we show that cardiac macrophages expand in humans and mice with diastolic dysfunction, which in mice was induced by either hypertension or advanced age. A higher murine myocardial macrophage density results from monocyte recruitment and increased hematopoiesis in bone marrow and spleen. In humans, we observed a parallel constellation of hematopoietic activation: circulating myeloid cells are more frequent, and splenic 18 F-FDG PET/CT imaging signal correlates with echocardiographic indices of diastolic dysfunction. While diastolic dysfunction develops, cardiac macrophages produce IL-10, activate fibroblasts, and stimulate collagen deposition, leading to impaired myocardial relaxation and increased myocardial stiffness. Deletion of IL-10 in macrophages improves diastolic function. These data imply expansion and phenotypic changes of cardiac macrophages as therapeutic targets for cardiac fibrosis leading to diastolic dysfunction. © 2018 Hulsmans et al.

  19. A biophysical model for defibrillation of cardiac tissue.

    PubMed Central

    Keener, J P; Panfilov, A V

    1996-01-01

    We propose a new model for electrical activity of cardiac tissue that incorporates the effects of cellular microstructure. As such, this model provides insight into the mechanism of direct stimulation and defibrillation of cardiac tissue after injection of large currents. To illustrate the usefulness of the model, numerical stimulations are used to show the difference between successful and unsuccessful defibrillation of large pieces of tissue. Images FIGURE 2 FIGURE 3 FIGURE 4 FIGURE 5 FIGURE 6 FIGURE 7 FIGURE 8 FIGURE 9 PMID:8874007

  20. Cardiac magnetic resonance imaging has limited additional yield in cryptogenic stroke evaluation after transesophageal echocardiography.

    PubMed

    Liberman, Ava L; Kalani, Rizwan E; Aw-Zoretic, Jessie; Sondag, Matthew; Daruwalla, Vistasp J; Mitter, Sumeet S; Bernstein, Richard; Collins, Jeremy D; Prabhakaran, Shyam

    2017-12-01

    Background The use of cardiac magnetic resonance imaging is increasing, but its role in the diagnostic work-up following ischemic stroke has received limited study. We aimed to explore the added yield of cardiac magnetic resonance imaging to identify cardio-aortic sources not detected by transesophageal echocardiography among patients with cryptogenic stroke. Methods A retrospective single-center cohort study was performed from 01 January 2009 to 01 March 2013. Consecutive patients who had both a stroke protocol cardiac magnetic resonance imaging and a transesophageal echocardiography preformed during a single hospitalization were included. All cardiac magnetic resonance imaging studies underwent independent, blinded review by two investigators. We applied the causative classification system for ischemic stroke to all patients, first blinded to cardiac magnetic resonance imaging results; we then reapplied the causative classification system using cardiac magnetic resonance imaging. Standard statistical tests to evaluate stroke subtype reclassification rates were used. Results Ninety-three patients were included in the final analysis; 68.8% were classified as cryptogenic stroke after initial diagnostic evaluation. Among patients with cryptogenic stroke, five (7.8%) were reclassified due to cardiac magnetic resonance imaging findings: one was reclassified as "cardio-aortic embolism evident" due to the presence of a patent foramen ovale and focal cardiac infarct and four were reclassified as "cardio-aortic embolism possible" due to mitral valve thickening (n = 1) or hypertensive cardiomyopathy (n = 3). Overall, findings on cardiac magnetic resonance imaging reduced the percentage of patients with cryptogenic stroke by slightly more than 1%. Conclusion Our stroke subtype reclassification rate after the addition of cardiac magnetic resonance imaging results to a diagnostic work-up which includes transesophageal echocardiography was very low. Prospective studies evaluating the role of cardiac magnetic resonance imaging and transesophageal echocardiography among patients with cryptogenic stroke should be considered.

  1. Cardiac function and perfusion dynamics measured on a beat-by-beat basis in the live mouse using ultra-fast 4D optoacoustic imaging

    NASA Astrophysics Data System (ADS)

    Ford, Steven J.; Deán-Ben, Xosé L.; Razansky, Daniel

    2015-03-01

    The fast heart rate (~7 Hz) of the mouse makes cardiac imaging and functional analysis difficult when studying mouse models of cardiovascular disease, and cannot be done truly in real-time and 3D using established imaging modalities. Optoacoustic imaging, on the other hand, provides ultra-fast imaging at up to 50 volumetric frames per second, allowing for acquisition of several frames per mouse cardiac cycle. In this study, we combined a recently-developed 3D optoacoustic imaging array with novel analytical techniques to assess cardiac function and perfusion dynamics of the mouse heart at high, 4D spatiotemporal resolution. In brief, the heart of an anesthetized mouse was imaged over a series of multiple volumetric frames. In another experiment, an intravenous bolus of indocyanine green (ICG) was injected and its distribution was subsequently imaged in the heart. Unique temporal features of the cardiac cycle and ICG distribution profiles were used to segment the heart from background and to assess cardiac function. The 3D nature of the experimental data allowed for determination of cardiac volumes at ~7-8 frames per mouse cardiac cycle, providing important cardiac function parameters (e.g., stroke volume, ejection fraction) on a beat-by-beat basis, which has been previously unachieved by any other cardiac imaging modality. Furthermore, ICG distribution dynamics allowed for the determination of pulmonary transit time and thus additional quantitative measures of cardiovascular function. This work demonstrates the potential for optoacoustic cardiac imaging and is expected to have a major contribution toward future preclinical studies of animal models of cardiovascular health and disease.

  2. Hyperbaric oxygen can induce neuroplasticity and improve cognitive functions of patients suffering from anoxic brain damage

    PubMed Central

    Hadanny, A.; Golan, H.; Fishlev, G.; Bechor, Y.; Volkov, O.; Suzin, G.; Ben-Jacob, E.; Efrati, S.

    2015-01-01

    Abstract Purpose: Cognitive impairment may occur in 42–50% of cardiac arrest survivors. Hyperbaric oxygen therapy (HBO2) has recently been shown to have neurotherapeutic effects in patients suffering from chronic cognitive impairments (CCI) consequent to stroke and mild traumatic brain injury. The objective of this study was to assess the neurotherapeutic effect of HBO2 in patients suffering from CCI due to cardiac arrest. Methods: Retrospective analysis of patients with CCI caused by cardiac arrest, treated with 60 daily sessions of HBO2. Evaluation included objective computerized cognitive tests (NeuroTrax), Activity of Daily Living (ADL) and Quality of life questionnaires. The results of these tests were compared with changes in brain activity as assessed by single photon emission computed tomography (SPECT) brain imaging. Results: The study included 11 cases of CCI patients. Patients were treated with HBO2, 0.5–7.5 years (mean 2.6 ± 0.6 years) after the cardiac arrest. HBO2 was found to induce modest, but statistically significant improvement in memory, attention and executive function (mean scores) of 12% , 20% and 24% respectively. The clinical improvements were found to be well correlated with increased brain activity in relevant brain areas as assessed by computerized analysis of the SPECT imaging. Conclusions: Although further research is needed, the results demonstrate the beneficial effects of HBO2 on CCI in patients after cardiac arrest, even months to years after the acute event. PMID:26409406

  3. Real-time MRI guidance of cardiac interventions.

    PubMed

    Campbell-Washburn, Adrienne E; Tavallaei, Mohammad A; Pop, Mihaela; Grant, Elena K; Chubb, Henry; Rhode, Kawal; Wright, Graham A

    2017-10-01

    Cardiac magnetic resonance imaging (MRI) is appealing to guide complex cardiac procedures because it is ionizing radiation-free and offers flexible soft-tissue contrast. Interventional cardiac MR promises to improve existing procedures and enable new ones for complex arrhythmias, as well as congenital and structural heart disease. Guiding invasive procedures demands faster image acquisition, reconstruction and analysis, as well as intuitive intraprocedural display of imaging data. Standard cardiac MR techniques such as 3D anatomical imaging, cardiac function and flow, parameter mapping, and late-gadolinium enhancement can be used to gather valuable clinical data at various procedural stages. Rapid intraprocedural image analysis can extract and highlight critical information about interventional targets and outcomes. In some cases, real-time interactive imaging is used to provide a continuous stream of images displayed to interventionalists for dynamic device navigation. Alternatively, devices are navigated relative to a roadmap of major cardiac structures generated through fast segmentation and registration. Interventional devices can be visualized and tracked throughout a procedure with specialized imaging methods. In a clinical setting, advanced imaging must be integrated with other clinical tools and patient data. In order to perform these complex procedures, interventional cardiac MR relies on customized equipment, such as interactive imaging environments, in-room image display, audio communication, hemodynamic monitoring and recording systems, and electroanatomical mapping and ablation systems. Operating in this sophisticated environment requires coordination and planning. This review provides an overview of the imaging technology used in MRI-guided cardiac interventions. Specifically, this review outlines clinical targets, standard image acquisition and analysis tools, and the integration of these tools into clinical workflow. 1 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2017;46:935-950. © 2017 International Society for Magnetic Resonance in Medicine.

  4. Dynamic heart phantom with functional mitral and aortic valves

    NASA Astrophysics Data System (ADS)

    Vannelli, Claire; Moore, John; McLeod, Jonathan; Ceh, Dennis; Peters, Terry

    2015-03-01

    Cardiac valvular stenosis, prolapse and regurgitation are increasingly common conditions, particularly in an elderly population with limited potential for on-pump cardiac surgery. NeoChord©, MitraClipand numerous stent-based transcatheter aortic valve implantation (TAVI) devices provide an alternative to intrusive cardiac operations; performed while the heart is beating, these procedures require surgeons and cardiologists to learn new image-guidance based techniques. Developing these visual aids and protocols is a challenging task that benefits from sophisticated simulators. Existing models lack features needed to simulate off-pump valvular procedures: functional, dynamic valves, apical and vascular access, and user flexibility for different activation patterns such as variable heart rates and rapid pacing. We present a left ventricle phantom with these characteristics. The phantom can be used to simulate valvular repair and replacement procedures with magnetic tracking, augmented reality, fluoroscopy and ultrasound guidance. This tool serves as a platform to develop image-guidance and image processing techniques required for a range of minimally invasive cardiac interventions. The phantom mimics in vivo mitral and aortic valve motion, permitting realistic ultrasound images of these components to be acquired. It also has a physiological realistic left ventricular ejection fraction of 50%. Given its realistic imaging properties and non-biodegradable composition—silicone for tissue, water for blood—the system promises to reduce the number of animal trials required to develop image guidance applications for valvular repair and replacement. The phantom has been used in validation studies for both TAVI image-guidance techniques1, and image-based mitral valve tracking algorithms2.

  5. Noninvasive cardiovascular imaging.

    PubMed

    Hartman, Robert J

    2014-01-01

    Over the past 2 decades, use of noninvasive cardiovascular imaging has increased dramatically. This article provides a brief synopsis of the current state of several technologies-- echocardiography, cardiac magnetic resonance imaging, and cardiac computed tomography--as well as a glimpse at future possibilities in cardiac imaging.

  6. Cardiac memory in patients with Wolff-Parkinson-White syndrome: noninvasive imaging of activation and repolarization before and after catheter ablation.

    PubMed

    Ghosh, Subham; Rhee, Edward K; Avari, Jennifer N; Woodard, Pamela K; Rudy, Yoram

    2008-08-26

    Cardiac memory refers to a change in ventricular repolarization induced by and persisting for minutes to months after cessation of a period of altered ventricular activation (eg, resulting from pacing or preexcitation in patients with Wolff-Parkinson-White syndrome). ECG imaging (ECGI) is a novel imaging modality for noninvasive electroanatomic mapping of epicardial activation and repolarization. Fourteen pediatric patients with Wolff-Parkinson-White syndrome and no other congenital disease, were imaged with ECGI a day before and 45 minutes, 1 week, and 1 month after successful catheter ablation. ECGI determined that preexcitation sites were consistent with sites of successful ablation in all cases to within a 1-hour arc of each atrioventricular annulus. In the preexcited rhythm, activation-recovery interval (ARI) was the longest (349+/-6 ms) in the area of preexcitation leading to high average base-to-apex ARI dispersion of 95+/-9 ms (normal is approximately 40 ms). The ARI dispersion remained the same 45 minutes after ablation, although the activation sequence was restored to normal. ARI dispersion was still high (79+/-9 ms) 1 week later and returned to normal (45+/-6 ms) 1 month after ablation. The study demonstrates that ECGI can noninvasively localize ventricular insertion sites of accessory pathways to guide ablation and evaluate its outcome in pediatric patients with Wolff-Parkinson-White syndrome. Wolff-Parkinson-White is associated with high ARI dispersion in the preexcited rhythm that persists after ablation and gradually returns to normal over a period of 1 month, demonstrating the presence of cardiac memory. The 1-month time course is consistent with transcriptional reprogramming and remodeling of ion channels.

  7. Imaging the Propagation of the Electromechanical Wave in Heart Failure Patients with Cardiac Resynchronization Therapy.

    PubMed

    Bunting, Ethan; Lambrakos, Litsa; Kemper, Paul; Whang, William; Garan, Hasan; Konofagou, Elisa

    2017-01-01

    Current electrocardiographic and echocardiographic measurements in heart failure (HF) do not take into account the complex interplay between electrical activation and local wall motion. The utilization of novel technologies to better characterize cardiac electromechanical behavior may lead to improved response rates with cardiac resynchronization therapy (CRT). Electromechanical wave imaging (EWI) is a noninvasive ultrasound-based technique that uses the transient deformations of the myocardium to track the intrinsic EW that precedes myocardial contraction. In this paper, we investigate the performance and reproducibility of EWI in the assessment of HF patients and CRT. EWI acquisitions were obtained in five healthy controls and 16 HF patients with and without CRT pacing. Responders (n = 8) and nonresponders (n = 8) to CRT were identified retrospectively on the basis of left ventricular (LV) reverse remodeling. Electromechanical activation maps were obtained in all patients and used to compute a quantitative parameter describing the mean LV lateral wall activation time (LWAT). Mean LWAT was increased by 52.1 ms in HF patients in native rhythm compared to controls (P < 0.01). For all HF patients, CRT pacing initiated a different electromechanical activation sequence. Responders exhibited a 56.4-ms ± 28.9-ms reduction in LWAT with CRT pacing (P < 0.01), while nonresponders showed no significant change. In this initial feasibility study, EWI was capable of characterizing local cardiac electromechanical behavior as it pertains to HF and CRT response. Activation sequences obtained with EWI allow for quantification of LV lateral wall electromechanical activation, thus providing a novel method for CRT assessment. © 2016 Wiley Periodicals, Inc.

  8. A study of reconstruction accuracy for a cardiac SPECT system with multi-segmental collimation

    NASA Astrophysics Data System (ADS)

    Yu, D.-C.; Chang, W.; Pan, T.-S.

    1997-06-01

    To improve the geometric efficiency of cardiac SPECT imaging, the authors previously proposed to use a multi-segmental collimation with a cylindrical geometry. The proposed collimator consists of multiple parallel-hole collimators with most of the segments directed toward a small central region, where the patient's heart should be positioned. This technique provides a significantly increased detection efficiency for the central region, but at the expense of reduced efficiency for the surrounding region. The authors have used computer simulations to evaluate the implication of this technique on the accuracy of the reconstructed cardiac images. Two imaging situations were simulated: 1) the heart well placed inside the central region, and 2) the heart shifted and partially outside the central region. A neighboring high-uptake liver was simulated for both imaging situations. The images were reconstructed and corrected for attenuation with ML-EM and OS-FM methods using a complete attenuation map. The results indicate that errors caused by projection truncation are not significant and are not strongly dependent on the activity of the liver when the heart is well positioned within the central region. When the heart is partially outside the central region, hybrid emission data (a combination of high-count projections from the central region and low-count projections from the background region) can be used to restore the activity of the truncated section of the myocardium. However, the variance of the image in the section of the myocardium outside the central region is increased by 2-3 times when 10% of the collimator segments are used to image the background region.

  9. Image based cardiac acceleration map using statistical shape and 3D+t myocardial tracking models; in-vitro study on heart phantom

    NASA Astrophysics Data System (ADS)

    Pashaei, Ali; Piella, Gemma; Planes, Xavier; Duchateau, Nicolas; de Caralt, Teresa M.; Sitges, Marta; Frangi, Alejandro F.

    2013-03-01

    It has been demonstrated that the acceleration signal has potential to monitor heart function and adaptively optimize Cardiac Resynchronization Therapy (CRT) systems. In this paper, we propose a non-invasive method for computing myocardial acceleration from 3D echocardiographic sequences. Displacement of the myocardium was estimated using a two-step approach: (1) 3D automatic segmentation of the myocardium at end-diastole using 3D Active Shape Models (ASM); (2) propagation of this segmentation along the sequence using non-rigid 3D+t image registration (temporal di eomorphic free-form-deformation, TDFFD). Acceleration was obtained locally at each point of the myocardium from local displacement. The framework has been tested on images from a realistic physical heart phantom (DHP-01, Shelley Medical Imaging Technologies, London, ON, CA) in which the displacement of some control regions was known. Good correlation has been demonstrated between the estimated displacement function from the algorithms and the phantom setup. Due to the limited temporal resolution, the acceleration signals are sparse and highly noisy. The study suggests a non-invasive technique to measure the cardiac acceleration that may be used to improve the monitoring of cardiac mechanics and optimization of CRT.

  10. Hybrid cardiac imaging with MR-CAT scan: a feasibility study.

    PubMed

    Hillenbrand, C; Sandstede, J; Pabst, T; Hahn, D; Haase, A; Jakob, P M

    2000-06-01

    We demonstrate the feasibility of a new versatile hybrid imaging concept, the combined acquisition technique (CAT), for cardiac imaging. The cardiac CAT approach, which combines new methodology with existing technology, essentially integrates fast low-angle shot (FLASH) and echoplanar imaging (EPI) modules in a sequential fashion, whereby each acquisition module is employed with independently optimized imaging parameters. One important CAT sequence optimization feature is the ability to use different bandwidths for different acquisition modules. Twelve healthy subjects were imaged using three cardiac CAT acquisition strategies: a) CAT was used to reduce breath-hold duration times while maintaining constant spatial resolution; b) CAT was used to increase spatial resolution in a given breath-hold time; and c) single-heart beat CAT imaging was performed. The results obtained demonstrate the feasibility of cardiac imaging using the CAT approach and the potential of this technique to accelerate the imaging process with almost conserved image quality. Copyright 2000 Wiley-Liss, Inc.

  11. 2017 Multimodality Appropriate Use Criteria for Noninvasive Cardiac Imaging: Expert Consensus of the Asian Society of Cardiovascular Imaging.

    PubMed

    Beck, Kyongmin Sarah; Kim, Jeong A; Choe, Yeon Hyeon; Hian, Sim Kui; Hoe, John; Hong, Yoo Jin; Kim, Sung Mok; Kim, Tae Hoon; Kim, Young Jin; Kim, Yun Hyeon; Kuribayashi, Sachio; Lee, Jongmin; Leong, Lilian; Lim, Tae-Hwan; Lu, Bin; Park, Jae Hyung; Sakuma, Hajime; Yang, Dong Hyun; Yaw, Tan Swee; Wan, Yung-Liang; Zhang, Zhaoqi; Zhao, Shihua; Yong, Hwan Seok

    2017-01-01

    In 2010, the Asian Society of Cardiovascular Imaging (ASCI) provided recommendations for cardiac CT and MRI, and this document reflects an update of the 2010 ASCI appropriate use criteria (AUC). In 2016, the ASCI formed a new working group for revision of AUC for noninvasive cardiac imaging. A major change that we made in this document is the rating of various noninvasive tests (exercise electrocardiogram, echocardiography, positron emission tomography, single-photon emission computed tomography, radionuclide imaging, cardiac magnetic resonance, and cardiac computed tomography/angiography), compared side by side for their applications in various clinical scenarios. Ninety-five clinical scenarios were developed from eight selected pre-existing guidelines and classified into four sections as follows: 1) detection of coronary artery disease, symptomatic or asymptomatic; 2) cardiac evaluation in various clinical scenarios; 3) use of imaging modality according to prior testing; and 4) evaluation of cardiac structure and function. The clinical scenarios were scored by a separate rating committee on a scale of 1-9 to designate appropriate use, uncertain use, or inappropriate use according to a modified Delphi method. Overall, the AUC ratings for CT were higher than those of previous guidelines. These new AUC provide guidance for clinicians choosing among available testing modalities for various cardiac diseases and are also unique, given that most previous AUC for noninvasive imaging include only one imaging technique. As cardiac imaging is multimodal in nature, we believe that these AUC will be more useful for clinical decision making.

  12. Cardiac imaging of congenital heart diseases during interventional procedures continues to evolve: Pros and cons of the main techniques.

    PubMed

    Hascoët, Sebastien; Warin-Fresse, Karine; Baruteau, Alban-Elouen; Hadeed, Khaled; Karsenty, Clement; Petit, Jérôme; Guérin, Patrice; Fraisse, Alain; Acar, Philippe

    2016-02-01

    Cardiac catheterization has contributed to the progress made in the management of patients with congenital heart disease (CHD). First, it allowed clarification of the diagnostic assessment of CHD, by offering a better understanding of normal cardiac physiology and the pathophysiology and anatomy of complex malformations. Then, it became an alternative to surgery and a major component of the therapeutic approach for some CHD lesions. Nowadays, techniques have evolved and cardiac catheterization is widely used to percutaneously close intracardiac shunts, to relieve obstructive valvar or vessel lesions, and for transcatheter valve replacement. Accurate imaging is mandatory to guide these procedures. Cardiac imaging during catheterization of CHD must provide accurate images of lesions, surrounding cardiac structures, medical devices and tools used to deliver them. Cardiac imaging has to be 'real-time' with an excellent temporal resolution to ensure 'eyes-hands' synchronization and 'device-target area' accurate positioning. In this comprehensive review, we provide an overview of conventional cardiac imaging tools used in the catheterization laboratory in daily practice, as well as the effect of recent evolution and future imaging modalities. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  13. Dual-Gated Motion-Frozen Cardiac PET with Flurpiridaz F 18.

    PubMed

    Slomka, Piotr J; Rubeaux, Mathieu; Le Meunier, Ludovic; Dey, Damini; Lazewatsky, Joel L; Pan, Tinsu; Dweck, Marc R; Newby, David E; Germano, Guido; Berman, Daniel S

    2015-12-01

    A novel PET radiotracer, Flurpiridaz F 18, has undergone phase II clinical trial evaluation as a high-resolution PET cardiac perfusion imaging agent. In a subgroup of patients imaged with this agent, we assessed the feasibility and benefit of simultaneous correction of respiratory and cardiac motion. In 16 patients, PET imaging was performed on a 4-ring scanner in dual cardiac and respiratory gating mode. Four sets of data were reconstructed with high-definition reconstruction (HD•PET): ungated and 8-bin electrocardiography-gated images using 5-min acquisition, optimal respiratory gating (ORG)-as developed for oncologic imaging-using a narrow range of breathing amplitude around end-expiration level with 35% of the counts in a 7-min acquisition, and 4-bin respiration-gated and 8-bin electrocardiography-gated images (32 bins in total) using the 7-min acquisition (dual-gating, using all data). Motion-frozen (MF) registration algorithms were applied to electrocardiography-gated and dual-gated data, creating cardiac-MF and dual-MF images. We computed wall thickness, wall/cavity contrast, and contrast-to-noise ratio for standard, ORG, cardiac-MF, and dual-MF images to assess image quality. The wall/cavity contrast was similar for ungated (9.3 ± 2.9) and ORG (9.5 ± 3.2) images and improved for cardiac-MF (10.8 ± 3.6) and dual-MF images (14.8 ± 8.0) (P < 0.05). The contrast-to-noise ratio was 22.2 ± 9.1 with ungated, 24.7 ± 12.2 with ORG, 35.5 ± 12.8 with cardiac-MF, and 42.1 ± 13.2 with dual-MF images (all P < 0.05). The wall thickness was significantly decreased (P < 0.05) with dual-MF (11.6 ± 1.9 mm) compared with ungated (13.9 ± 2.8 mm), ORG (13.1 ± 2.9 mm), and cardiac-MF images (12.1 ± 2.7 mm). Dual (respiratory/cardiac)-gated perfusion imaging with Flurpiridaz F 18 is feasible and improves image resolution, contrast, and contrast-to-noise ratio when MF registration methods are applied. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  14. A joint procedural position statement on imaging in cardiac sarcoidosis: from the Cardiovascular and Inflammation & Infection Committees of the European Association of Nuclear Medicine, the European Association of Cardiovascular Imaging, and the American Society of Nuclear Cardiology.

    PubMed

    2017-10-01

    This joint position paper illustrates the role and the correct use of echocardiography, radionuclide imaging with 18F-fluorodeoxyglucose positron emission tomography, radionuclide myocardial perfusion imaging and cardiovascular magnetic resonance imaging for the evaluation and management of patients with known or suspected cardiac sarcoidosis. This position paper will aid in standardizing imaging for cardiac sarcoidosis and may facilitate clinical trials and pooling of multi-centre data on cardiac sarcoidosis. Proposed flow charts for the work up and management of cardiac sarcoidosis are included. Copyright © 2017 European Association of Nuclear Medicine, the European Association of Cardiovascular Imaging, and the American Society of Nuclear Cardiology.

  15. False dyssynchrony: problem with image-based cardiac functional analysis using x-ray computed tomography

    NASA Astrophysics Data System (ADS)

    Kidoh, Masafumi; Shen, Zeyang; Suzuki, Yuki; Ciuffo, Luisa; Ashikaga, Hiroshi; Fung, George S. K.; Otake, Yoshito; Zimmerman, Stefan L.; Lima, Joao A. C.; Higuchi, Takahiro; Lee, Okkyun; Sato, Yoshinobu; Becker, Lewis C.; Fishman, Elliot K.; Taguchi, Katsuyuki

    2017-03-01

    We have developed a digitally synthesized patient which we call "Zach" (Zero millisecond Adjustable Clinical Heart) phantom, which allows for an access to the ground truth and assessment of image-based cardiac functional analysis (CFA) using CT images with clinically realistic settings. The study using Zach phantom revealed a major problem with image-based CFA: "False dyssynchrony." Even though the true motion of wall segments is in synchrony, it may appear to be dyssynchrony with the reconstructed cardiac CT images. It is attributed to how cardiac images are reconstructed and how wall locations are updated over cardiac phases. The presence and the degree of false dyssynchrony may vary from scan-to-scan, which could degrade the accuracy and the repeatability (or precision) of image-based CT-CFA exams.

  16. Integrated imaging of cardiac anatomy, physiology, and viability.

    PubMed

    Arrighi, James A

    2009-03-01

    Technologic developments in imaging will have a significant impact on cardiac imaging over the next decade. These advances will permit more detailed assessment of cardiac anatomy, complex assessment of cardiac physiology, and integration of anatomic and physiologic data. The distinction between anatomic and physiologic imaging is important. For assessing patients with known or suspected coronary artery disease, physiologic and anatomic imaging data are complementary. The strength of anatomic imaging rests in its ability to detect the presence of disease, whereas physiologic imaging techniques assess the impact of disease, such as whether a coronary atherosclerotic lesion limits myocardial blood flow. Research indicates that physiologic data are more prognostically important than anatomic data, but both may be important in patient management decisions. Integrated cardiac imaging is an evolving field, with many potential indications. These include assessment of coronary stenosis, myocardial viability, anatomic and physiologic characterization of atherosclerotic plaque, and advanced molecular imaging.

  17. Magnetic Resonance Imaging as a Predictor of Survival Free of Life-Threatening Arrhythmias and Transplantation in Cardiac Sarcoidosis.

    PubMed

    Ekström, Kaj; Lehtonen, Jukka; Hänninen, Helena; Kandolin, Riina; Kivistö, Sari; Kupari, Markku

    2016-05-02

    Cardiac magnetic resonance imaging has a key role in today's diagnosis of cardiac sarcoidosis. We set out to investigate whether cardiac magnetic resonance imaging also helps predict outcome in cardiac sarcoidosis. Our work involved 59 patients with cardiac sarcoidosis (38 female, mean age 46±10 years) seen at our hospital since February 2004 and followed up after contrast-enhanced cardiac magnetic resonance imaging. The extent of myocardial late gadolinium enhancement (measured as percentage of left ventricular mass), the volumes and ejection fractions of the left and right ventricles, and the thickness of the basal interventricular septum were determined and analyzed for prognostic significance. By April 2015, 23 patients had reached the study's end point, consisting of a composite of cardiac death (n=3), cardiac transplantation (n=1), and occurrence of life-threatening ventricular tachyarrhythmias (n=19; ventricular fibrillation in 5 and sustained ventricular tachycardia in 14 patients). In univariate analysis, myocardial extent of late gadolinium enhancement predicted event-free survival, as did scar-like thinning (<4 mm) of the basal interventricular septum and the ejection fraction of the right ventricle (P<0.05 for all). In multivariate Cox regression analysis, extent of late gadolinium enhancement was the only independent predictor of outcome events on cardiac magnetic resonance imaging, with a hazard ratio of 2.22 per tertile (95% CI 1.07-4.59). An extent of late gadolinium enhancement >22% (third tertile) had positive and negative predictive values for serious cardiac events of 75% and 76%, respectively. Findings on cardiac magnetic resonance imaging and the extent of myocardial late gadolinium enhancement in particular help predict serious cardiac events in cardiac sarcoidosis. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  18. Extracting cardiac shapes and motion of the chick embryo heart outflow tract from four-dimensional optical coherence tomography images

    NASA Astrophysics Data System (ADS)

    Yin, Xin; Liu, Aiping; Thornburg, Kent L.; Wang, Ruikang K.; Rugonyi, Sandra

    2012-09-01

    Recent advances in optical coherence tomography (OCT), and the development of image reconstruction algorithms, enabled four-dimensional (4-D) (three-dimensional imaging over time) imaging of the embryonic heart. To further analyze and quantify the dynamics of cardiac beating, segmentation procedures that can extract the shape of the heart and its motion are needed. Most previous studies analyzed cardiac image sequences using manually extracted shapes and measurements. However, this is time consuming and subject to inter-operator variability. Automated or semi-automated analyses of 4-D cardiac OCT images, although very desirable, are also extremely challenging. This work proposes a robust algorithm to semi automatically detect and track cardiac tissue layers from 4-D OCT images of early (tubular) embryonic hearts. Our algorithm uses a two-dimensional (2-D) deformable double-line model (DLM) to detect target cardiac tissues. The detection algorithm uses a maximum-likelihood estimator and was successfully applied to 4-D in vivo OCT images of the heart outflow tract of day three chicken embryos. The extracted shapes captured the dynamics of the chick embryonic heart outflow tract wall, enabling further analysis of cardiac motion.

  19. Isolated, broad-based apical diverticulum: cardiac magnetic resonance is a "terminator" of cardiac imaging modality for the evaluation of cardiac apex.

    PubMed

    Ahn, Hyo-Suk; Kim, Hyung-Kwan; Park, Eun-Ah; Lee, Whal; Park, Jae-Hyung; Sohn, Dae-Won

    2013-10-01

    In spite of the frequent involvement of many cardiac diseases, it is difficult to evaluate the left ventricular apex in detail with transthoracic echocardiography, a first-line imaging modality in cardiovascular diseases, because the apex is very closely located at the echocardiographic probe. Cardiac magnetic resonance enables us to evaluate the cardiac apex without any limitation to the image acquisition. We here present a case regarding a broad-based apical diverticulum, which was initially confused with apical aneurysm.

  20. Noise suppressed partial volume correction for cardiac SPECT/CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chan, Chung; Liu, Chi, E-mail: chi.liu@yale.edu

    Purpose: Partial volume correction (PVC) methods typically improve quantification at the expense of increased image noise and reduced reproducibility. In this study, the authors developed a novel voxel-based PVC method that incorporates anatomical knowledge to improve quantification while suppressing noise for cardiac SPECT/CT imaging. Methods: In the proposed method, the SPECT images were first reconstructed using anatomical-based maximum a posteriori (AMAP) with Bowsher’s prior to penalize noise while preserving boundaries. A sequential voxel-by-voxel PVC approach (Yang’s method) was then applied on the AMAP reconstruction using a template response. This template response was obtained by forward projecting a template derived frommore » a contrast-enhanced CT image, and then reconstructed using AMAP to model the partial volume effects (PVEs) introduced by both the system resolution and the smoothing applied during reconstruction. To evaluate the proposed noise suppressed PVC (NS-PVC), the authors first simulated two types of cardiac SPECT studies: a {sup 99m}Tc-tetrofosmin myocardial perfusion scan and a {sup 99m}Tc-labeled red blood cell (RBC) scan on a dedicated cardiac multiple pinhole SPECT/CT at both high and low count levels. The authors then applied the proposed method on a canine equilibrium blood pool study following injection with {sup 99m}Tc-RBCs at different count levels by rebinning the list-mode data into shorter acquisitions. The proposed method was compared to MLEM reconstruction without PVC, two conventional PVC methods, including Yang’s method and multitarget correction (MTC) applied on the MLEM reconstruction, and AMAP reconstruction without PVC. Results: The results showed that the Yang’s method improved quantification, however, yielded increased noise and reduced reproducibility in the regions with higher activity. MTC corrected for PVE on high count data with amplified noise, although yielded the worst performance among all the methods tested on low-count data. AMAP effectively suppressed noise and reduced the spill-in effect in the low activity regions. However it was unable to reduce the spill-out effect in high activity regions. NS-PVC yielded superior performance in terms of both quantitative assessment and visual image quality while improving reproducibility. Conclusions: The results suggest that NS-PVC may be a promising PVC algorithm for application in low-dose protocols, and in gated and dynamic cardiac studies with low counts.« less

  1. 2017 Multimodality Appropriate Use Criteria for Noninvasive Cardiac Imaging: Expert Consensus of the Asian Society of Cardiovascular Imaging

    PubMed Central

    Beck, Kyongmin Sarah; Kim, Jeong A; Choe, Yeon Hyeon; Hian, Sim Kui; Hoe, John; Hong, Yoo Jin; Kim, Sung Mok; Kim, Tae Hoon; Kim, Young Jin; Kim, Yun Hyeon; Kuribayashi, Sachio; Lee, Jongmin; Leong, Lilian; Lim, Tae-Hwan; Lu, Bin; Park, Jae Hyung; Sakuma, Hajime; Yang, Dong Hyun; Yaw, Tan Swee; Wan, Yung-Liang; Zhang, Zhaoqi; Zhao, Shihua

    2017-01-01

    In 2010, the Asian Society of Cardiovascular Imaging (ASCI) provided recommendations for cardiac CT and MRI, and this document reflects an update of the 2010 ASCI appropriate use criteria (AUC). In 2016, the ASCI formed a new working group for revision of AUC for noninvasive cardiac imaging. A major change that we made in this document is the rating of various noninvasive tests (exercise electrocardiogram, echocardiography, positron emission tomography, single-photon emission computed tomography, radionuclide imaging, cardiac magnetic resonance, and cardiac computed tomography/angiography), compared side by side for their applications in various clinical scenarios. Ninety-five clinical scenarios were developed from eight selected pre-existing guidelines and classified into four sections as follows: 1) detection of coronary artery disease, symptomatic or asymptomatic; 2) cardiac evaluation in various clinical scenarios; 3) use of imaging modality according to prior testing; and 4) evaluation of cardiac structure and function. The clinical scenarios were scored by a separate rating committee on a scale of 1–9 to designate appropriate use, uncertain use, or inappropriate use according to a modified Delphi method. Overall, the AUC ratings for CT were higher than those of previous guidelines. These new AUC provide guidance for clinicians choosing among available testing modalities for various cardiac diseases and are also unique, given that most previous AUC for noninvasive imaging include only one imaging technique. As cardiac imaging is multimodal in nature, we believe that these AUC will be more useful for clinical decision making. PMID:29089819

  2. Assessing the Atrial Electromechanical Coupling during Atrial Focal Tachycardia, Flutter, and Fibrillation using Electromechanical Wave Imaging in Humans

    PubMed Central

    Provost, Jean; Costet, Alexandre; Wan, Elaine; Gambhir, Alok; Whang, William; Garan, Hasan; Konofagou, Elisa E.

    2015-01-01

    Minimally-invasive treatments of cardiac arrhythmias such as radio-frequency ablation are gradually gaining in importance in clinical practice but still lack a noninvasive imaging modality which provides insight into the source or focus of an arrhythmia. Cardiac deformations imaged at high temporal and spatial resolution can be used to elucidate the electrical activation sequence in normal and paced human subjects non-invasively and could potentially aid to better plan and monitor ablation-based arrhythmia treatments. In this study, a novel ultrasound-based method is presented that can be used to quantitatively characterize focal and reentrant arrhythmias. Spatio-temporal maps of the full-view of the atrial and ventricular mechanics were obtained in a single heartbeat, revealing with otherwise unobtainable detail the electromechanical patterns of atrial flutter, fibrillation, and tachycardia in humans. During focal arrhythmias such as premature ventricular complex and focal atrial tachycardia, the previously developed electromechanical wave imaging methodology is hereby shown capable of identifying the location of the focal zone and the subsequent propagation of cardiac activation. During reentrant arrhythmias such as atrial flutter and fibrillation, Fourier analysis of the strains revealed highly correlated mechanical and electrical cycle lengths and propagation patterns. High frame rate ultrasound imaging of the heart can be used non-invasively and in real time, to characterize the lesser-known mechanical aspects of atrial and ventricular arrhythmias, also potentially assisting treatment planning for intraoperative and longitudinal monitoring of arrhythmias. PMID:26361338

  3. Heart MRI

    MedlinePlus

    Magnetic resonance imaging - cardiac; Magnetic resonance imaging - heart; Nuclear magnetic resonance - cardiac; NMR - cardiac; MRI of the heart; Cardiomyopathy - MRI; Heart failure - MRI; Congenital heart disease - MRI

  4. Automated processing of first-pass radionuclide angiocardiography by factor analysis of dynamic structures.

    PubMed

    Cavailloles, F; Bazin, J P; Capderou, A; Valette, H; Herbert, J L; Di Paola, R

    1987-05-01

    A method for automatic processing of cardiac first-pass radionuclide study is presented. This technique, factor analysis of dynamic structures (FADS) provides an automatic separation of anatomical structures according to their different temporal behaviour, even if they are superimposed. FADS has been applied to 76 studies. A description of factor patterns obtained in various pathological categories is presented. FADS provides easy diagnosis of shunts and tricuspid insufficiency. Quantitative information derived from the factors (cardiac output and mean transit time) were compared to those obtained by the region of interest method. Using FADS, a higher correlation with cardiac catheterization was found for cardiac output calculation. Thus compared to the ROI method, FADS presents obvious advantages: a good separation of overlapping cardiac chambers is obtained; this operator independant method provides more objective and reproducible results. A number of parameters of the cardio-pulmonary function can be assessed by first-pass radionuclide angiocardiography (RNA) [1,2]. Usually, they are calculated using time-activity curves (TAC) from regions of interest (ROI) drawn on the cardiac chambers and the lungs. This method has two main drawbacks: (1) the lack of inter and intra-observers reproducibility; (2) the problem of crosstalk which affects the evaluation of the cardio-pulmonary performance. The crosstalk on planar imaging is due to anatomical superimposition of the cardiac chambers and lungs. The activity measured in any ROI is the sum of the activity in several organs and 'decontamination' of the TAC cannot easily be performed using the ROI method [3]. Factor analysis of dynamic structures (FADS) [4,5] can solve the two problems mentioned above. It provides an automatic separation of anatomical structures according to their different temporal behaviour, even if they are superimposed. The resulting factors are estimates of the time evolution of the activity in each structure (underlying physiological components), and the associated factor images are estimates of the spatial distribution of each factor. The aim of this study was to assess the reliability of FADS in first pass RNA and compare the results to those obtained by the ROI method which is generally considered as the routine procedure.

  5. Biodistribution and radiation dosimetry of LMI1195: first-in-human study of a novel 18F-labeled tracer for imaging myocardial innervation.

    PubMed

    Sinusas, Albert J; Lazewatsky, Joel; Brunetti, Jacqueline; Heller, Gary; Srivastava, Ajay; Liu, Yi-Hwa; Sparks, Richard; Puretskiy, Andrey; Lin, Shu-fei; Crane, Paul; Carson, Richard E; Lee, L Veronica

    2014-09-01

    A novel (18)F-labeled ligand for the norepinephrine transporter (N-[3-bromo-4-(3-(18)F-fluoro-propoxy)-benzyl]-guanidine [LMI1195]) is in clinical development for mapping cardiac nerve terminals in vivo using PET. Human safety, whole-organ biodistribution, and radiation dosimetry of LMI1195 were evaluated in a phase 1 clinical trial. Twelve healthy subjects at 3 clinical sites were injected intravenously with 150-250 MBq of LMI1195. Dynamic PET images were obtained over the heart for 10 min, followed by sequential whole-body images for approximately 5 h. Blood samples were obtained, and heart rate, electrocardiogram, and blood pressure were monitored before and during imaging. Residence times were determined from multiexponential regression of organ region-of-interest data normalized by administered activity (AA). Radiation dose estimates were calculated using OLINDA/EXM. Myocardial, lung, liver, and blood-pool standardized uptake values were determined at different time intervals. No adverse events due to LMI1195 were seen. Blood radioactivity cleared quickly, whereas myocardial uptake remained stable and uniform throughout the heart over 4 h. Liver and lung activity cleared relatively rapidly, providing favorable target-to-background ratios for cardiac imaging. The urinary bladder demonstrated the largest peak uptake (18.3% AA), followed by the liver (15.5% AA). The mean effective dose was 0.026 ± 0.0012 mSv/MBq. Approximately 1.6% AA was seen in the myocardium initially, remaining above 1.5% AA (decay-corrected) through 4 h after injection. The myocardium-to-liver ratio was approximately unity initially, increasing to more than 2 at 4 h. These preliminary data suggest that LMI1195 is well tolerated and yields a radiation dose comparable to that of other commonly used PET radiopharmaceuticals. The kinetics of myocardial and adjacent organ activity suggest that cardiac imaging should be possible with acceptable patient radiation dose. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  6. Lp-Norm Regularization in Volumetric Imaging of Cardiac Current Sources

    PubMed Central

    Rahimi, Azar; Xu, Jingjia; Wang, Linwei

    2013-01-01

    Advances in computer vision have substantially improved our ability to analyze the structure and mechanics of the heart. In comparison, our ability to observe and analyze cardiac electrical activities is much limited. The progress to computationally reconstruct cardiac current sources from noninvasive voltage data sensed on the body surface has been hindered by the ill-posedness and the lack of a unique solution of the reconstruction problem. Common L2- and L1-norm regularizations tend to produce a solution that is either too diffused or too scattered to reflect the complex spatial structure of current source distribution in the heart. In this work, we propose a general regularization with Lp-norm (1 < p < 2) constraint to bridge the gap and balance between an overly smeared and overly focal solution in cardiac source reconstruction. In a set of phantom experiments, we demonstrate the superiority of the proposed Lp-norm method over its L1 and L2 counterparts in imaging cardiac current sources with increasing extents. Through computer-simulated and real-data experiments, we further demonstrate the feasibility of the proposed method in imaging the complex structure of excitation wavefront, as well as current sources distributed along the postinfarction scar border. This ability to preserve the spatial structure of source distribution is important for revealing the potential disruption to the normal heart excitation. PMID:24348735

  7. Patient-specific models of cardiac biomechanics

    NASA Astrophysics Data System (ADS)

    Krishnamurthy, Adarsh; Villongco, Christopher T.; Chuang, Joyce; Frank, Lawrence R.; Nigam, Vishal; Belezzuoli, Ernest; Stark, Paul; Krummen, David E.; Narayan, Sanjiv; Omens, Jeffrey H.; McCulloch, Andrew D.; Kerckhoffs, Roy C. P.

    2013-07-01

    Patient-specific models of cardiac function have the potential to improve diagnosis and management of heart disease by integrating medical images with heterogeneous clinical measurements subject to constraints imposed by physical first principles and prior experimental knowledge. We describe new methods for creating three-dimensional patient-specific models of ventricular biomechanics in the failing heart. Three-dimensional bi-ventricular geometry is segmented from cardiac CT images at end-diastole from patients with heart failure. Human myofiber and sheet architecture is modeled using eigenvectors computed from diffusion tensor MR images from an isolated, fixed human organ-donor heart and transformed to the patient-specific geometric model using large deformation diffeomorphic mapping. Semi-automated methods were developed for optimizing the passive material properties while simultaneously computing the unloaded reference geometry of the ventricles for stress analysis. Material properties of active cardiac muscle contraction were optimized to match ventricular pressures measured by cardiac catheterization, and parameters of a lumped-parameter closed-loop model of the circulation were estimated with a circulatory adaptation algorithm making use of information derived from echocardiography. These components were then integrated to create a multi-scale model of the patient-specific heart. These methods were tested in five heart failure patients from the San Diego Veteran's Affairs Medical Center who gave informed consent. The simulation results showed good agreement with measured echocardiographic and global functional parameters such as ejection fraction and peak cavity pressures.

  8. Imaging the propagation of the electromechanical wave in heart failure patients with cardiac resynchronization therapy

    PubMed Central

    Bunting, Ethan; Lambrakos, Litsa; Kemper, Paul; Whang, William; Garan, Hasan; Konofagou, Elisa

    2016-01-01

    Background Current electrocardiographic and echocardiographic measurements in heart failure (HF) do not take into account the complex interplay between electrical activation and local wall motion. The utilization of novel technologies to better characterize cardiac electromechanical behavior may lead to improved response rates with cardiac resynchronization therapy (CRT). Electromechanical Wave Imaging (EWI) is a non-invasive ultrasound-based technique that uses the transient deformations of the myocardium to track the intrinsic electromechanical wave that precedes myocardial contraction. In this paper, we investigate the performance and reproducibility of EWI in the assessment of HF patients and CRT. Methods EWI acquisitions were obtained in 5 healthy controls and 16 HF patients with and without CRT pacing. Responders (n=8) and non-responders (n=8) to CRT were identified retrospectively on the basis of left ventricular (LV) reverse remodeling. Electromechanical activation maps were obtained in all patients and used to compute a quantitative parameter describing the mean activation time of the LV lateral wall (LWAT). Results Mean LWAT was increased by 52.1 ms in HF patients in native rhythm compared to controls (p<0.01). For all HF patients, CRT pacing initiated a different electromechanical activation sequence. Responders exhibited a 56.4±28.9 ms reduction in LWAT with CRT pacing (p<0.01), while non-responders showed no significant change. Conclusion In this initial feasibility study, EWI was capable of characterizing local cardiac electromechanical behavior as it pertains to HF and CRT response. Activation sequences obtained with EWI allow for quantification of LV lateral wall electromechanical activation, thus providing a novel method for CRT assessment. PMID:27790723

  9. Determination of Cardiac Output and Ejection Fraction with the Dual Cardiac Probe

    PubMed Central

    Cardenas, Carlos G.; Depuey, E. Gordon; Thompson, Wayne L.; Garcia, Efrain; Burdine, John A.

    1983-01-01

    Cardiac output and left ventricular ejection fraction were determined noninvasively at the bedside in 26 patients by using a dual scintillation probe. The probe is a nonimaging detector that records a high frequency time-activity curve of the passage of an intravenously injected radioactive bolus through the heart. Results were correlated with ejection fraction measured by biplane cineangiography (r = 0.80) and cardiac output determined by green dye dilution (R = 0.86). It is concluded that the dual probe provides an accurate noninvasive means of measuring these parameters, and that it may be particularly applicable to serial measurements in patients in the intensive care unit. Images PMID:15227151

  10. Feature tracking cardiac magnetic resonance imaging: A review of a novel non-invasive cardiac imaging technique

    PubMed Central

    Rahman, Zia Ur; Sethi, Pooja; Murtaza, Ghulam; Virk, Hafeez Ul Hassan; Rai, Aitzaz; Mahmod, Masliza; Schoondyke, Jeffrey; Albalbissi, Kais

    2017-01-01

    Cardiovascular disease is a leading cause of morbidity and mortality globally. Early diagnostic markers are gaining popularity for better patient care disease outcomes. There is an increasing interest in noninvasive cardiac imaging biomarkers to diagnose subclinical cardiac disease. Feature tracking cardiac magnetic resonance imaging is a novel post-processing technique that is increasingly being employed to assess global and regional myocardial function. This technique has numerous applications in structural and functional diagnostics. It has been validated in multiple studies, although there is still a long way to go for it to become routine standard of care. PMID:28515849

  11. Extracting cardiac myofiber orientations from high frequency ultrasound images

    NASA Astrophysics Data System (ADS)

    Qin, Xulei; Cong, Zhibin; Jiang, Rong; Shen, Ming; Wagner, Mary B.; Kirshbom, Paul; Fei, Baowei

    2013-03-01

    Cardiac myofiber plays an important role in stress mechanism during heart beating periods. The orientation of myofibers decides the effects of the stress distribution and the whole heart deformation. It is important to image and quantitatively extract these orientations for understanding the cardiac physiological and pathological mechanism and for diagnosis of chronic diseases. Ultrasound has been wildly used in cardiac diagnosis because of its ability of performing dynamic and noninvasive imaging and because of its low cost. An extraction method is proposed to automatically detect the cardiac myofiber orientations from high frequency ultrasound images. First, heart walls containing myofibers are imaged by B-mode high frequency (<20 MHz) ultrasound imaging. Second, myofiber orientations are extracted from ultrasound images using the proposed method that combines a nonlinear anisotropic diffusion filter, Canny edge detector, Hough transform, and K-means clustering. This method is validated by the results of ultrasound data from phantoms and pig hearts.

  12. Demons versus Level-Set motion registration for coronary 18F-sodium fluoride PET.

    PubMed

    Rubeaux, Mathieu; Joshi, Nikhil; Dweck, Marc R; Fletcher, Alison; Motwani, Manish; Thomson, Louise E; Germano, Guido; Dey, Damini; Berman, Daniel S; Newby, David E; Slomka, Piotr J

    2016-02-27

    Ruptured coronary atherosclerotic plaques commonly cause acute myocardial infarction. It has been recently shown that active microcalcification in the coronary arteries, one of the features that characterizes vulnerable plaques at risk of rupture, can be imaged using cardiac gated 18 F-sodium fluoride ( 18 F-NaF) PET. We have shown in previous work that a motion correction technique applied to cardiac-gated 18 F-NaF PET images can enhance image quality and improve uptake estimates. In this study, we further investigated the applicability of different algorithms for registration of the coronary artery PET images. In particular, we aimed to compare demons vs. level-set nonlinear registration techniques applied for the correction of cardiac motion in coronary 18 F-NaF PET. To this end, fifteen patients underwent 18 F-NaF PET and prospective coronary CT angiography (CCTA). PET data were reconstructed in 10 ECG gated bins; subsequently these gated bins were registered using demons and level-set methods guided by the extracted coronary arteries from CCTA, to eliminate the effect of cardiac motion on PET images. Noise levels, target-to-background ratios (TBR) and global motion were compared to assess image quality. Compared to the reference standard of using only diastolic PET image (25% of the counts from PET acquisition), cardiac motion registration using either level-set or demons techniques almost halved image noise due to the use of counts from the full PET acquisition and increased TBR difference between 18 F-NaF positive and negative lesions. The demons method produces smoother deformation fields, exhibiting no singularities (which reflects how physically plausible the registration deformation is), as compared to the level-set method, which presents between 4 and 8% of singularities, depending on the coronary artery considered. In conclusion, the demons method produces smoother motion fields as compared to the level-set method, with a motion that is physiologically plausible. Therefore, level-set technique will likely require additional post-processing steps. On the other hand, the observed TBR increases were the highest for the level-set technique. Further investigations of the optimal registration technique of this novel coronary PET imaging technique are warranted.

  13. Demons versus level-set motion registration for coronary 18F-sodium fluoride PET

    NASA Astrophysics Data System (ADS)

    Rubeaux, Mathieu; Joshi, Nikhil; Dweck, Marc R.; Fletcher, Alison; Motwani, Manish; Thomson, Louise E.; Germano, Guido; Dey, Damini; Berman, Daniel S.; Newby, David E.; Slomka, Piotr J.

    2016-03-01

    Ruptured coronary atherosclerotic plaques commonly cause acute myocardial infarction. It has been recently shown that active microcalcification in the coronary arteries, one of the features that characterizes vulnerable plaques at risk of rupture, can be imaged using cardiac gated 18F-sodium fluoride (18F-NaF) PET. We have shown in previous work that a motion correction technique applied to cardiac-gated 18F-NaF PET images can enhance image quality and improve uptake estimates. In this study, we further investigated the applicability of different algorithms for registration of the coronary artery PET images. In particular, we aimed to compare demons vs. level-set nonlinear registration techniques applied for the correction of cardiac motion in coronary 18F-NaF PET. To this end, fifteen patients underwent 18F-NaF PET and prospective coronary CT angiography (CCTA). PET data were reconstructed in 10 ECG gated bins; subsequently these gated bins were registered using demons and level-set methods guided by the extracted coronary arteries from CCTA, to eliminate the effect of cardiac motion on PET images. Noise levels, target-to-background ratios (TBR) and global motion were compared to assess image quality. Compared to the reference standard of using only diastolic PET image (25% of the counts from PET acquisition), cardiac motion registration using either level-set or demons techniques almost halved image noise due to the use of counts from the full PET acquisition and increased TBR difference between 18F-NaF positive and negative lesions. The demons method produces smoother deformation fields, exhibiting no singularities (which reflects how physically plausible the registration deformation is), as compared to the level-set method, which presents between 4 and 8% of singularities, depending on the coronary artery considered. In conclusion, the demons method produces smoother motion fields as compared to the level-set method, with a motion that is physiologically plausible. Therefore, level-set technique will likely require additional post-processing steps. On the other hand, the observed TBR increases were the highest for the level-set technique. Further investigations of the optimal registration technique of this novel coronary PET imaging technique are warranted.

  14. Cardiac and pericardial tumors: A potential application of positron emission tomography-magnetic resonance imaging.

    PubMed

    Fathala, Ahmed; Abouzied, Mohei; AlSugair, Abdul-Aziz

    2017-07-26

    Cardiac and pericardial masses may be neoplastic, benign and malignant, non-neoplastic such as thrombus or simple pericardial cysts, or normal variants cardiac structure can also be a diagnostic challenge. Currently, there are several imaging modalities for diagnosis of cardiac masses; each technique has its inherent advantages and disadvantages. Echocardiography, is typically the initial test utilizes in such cases, Echocardiography is considered the test of choice for evaluation and detection of cardiac mass, it is widely available, portable, with no ionizing radiation and provides comprehensive evaluation of cardiac function and valves, however, echocardiography is not very helpful in many cases such as evaluation of extracardiac extension of mass, poor tissue characterization, and it is non diagnostic in some cases. Cross sectional imaging with cardiac computed tomography provides a three dimensional data set with excellent spatial resolution but utilizes ionizing radiation, intravenous iodinated contrast and relatively limited functional evaluation of the heart. Cardiac magnetic resonance imaging (CMR) has excellent contrast resolution that allows superior soft tissue characterization. CMR offers comprehensive evaluation of morphology, function, tissue characterization. The great benefits of CMR make CMR a highly useful tool in the assessment of cardiac masses. (Fluorine 18) fluorodeoxygluocse (FDG) positron emission tomography (PET) has become a corner stone in several oncological application such as tumor staging, restaging, treatment efficiency, FDG is a very useful imaging modality in evaluation of cardiac masses. A recent advance in the imaging technology has been the development of integrated PET-MRI system that utilizes the advantages of PET and MRI in a single examination. FDG PET-MRI provides complementary information on evaluation of cardiac masses. The purpose of this review is to provide several clinical scenarios on the incremental value of PET and MRI in the evaluation of cardiac masses.

  15. Cardiac Metastasis from Invasive Thymoma Via the Superior Vena Cava: Cardiac MRI Findings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dursun, Memduh, E-mail: memduhdursun@yahoo.com; Sarvar, Sadik; Cekrezi, Bledi

    2008-07-15

    Cardiac tumors are rare, and metastatic deposits are more common than primary cardiac tumors. We present cardiac magnetic resonance imaging (MRI) findings of a 50-year-old woman with invasive thymoma. Cardiac MRI revealed a heterogeneous, lobulated anterior mediastinal mass invading the superior vena cava and extending to the right atrium. In cine images there was no invasion to the right atrial wall.

  16. Preparing hearts and minds: cardiac slowing and a cortical inhibitory network.

    PubMed

    Jennings, J R; van der Molen, M W; Tanase, C

    2009-11-01

    Preparing for a cued, speeded response induces a set of physiological changes. A review of the psychophysiology of preparation suggested that inhibition of action was an important process among the constellation of changes constituting attentive preparation. The current experiment combined event-related functional magnetic resonance imaging and cardiac inter-beat interval measures in an experiment that compared preparing for a response, watching stimuli without responding, and responding in the absence of preparation. Ten college-aged participants were tested in an initial psychophysiological experiment followed by two scanning sessions during which reverse spiral imaging was performed concurrent with inter-beat interval measurement. Two analytic approaches were used to confirm blood oxygenation level dependent responses during preparation, and these converged to show inferior prefrontal and related subthalamic nuclei activity in the context of other known changes related to brain attentional networks. Subthalamic nuclei changes were related to the depth of preparatory cardiac deceleration. This pattern of findings suggests that preparation involves the activation of a complex inhibitory neural network implicating brain and autonomic nervous systems.

  17. A System for Seismocardiography-Based Identification of Quiescent Heart Phases: Implications for Cardiac Imaging

    PubMed Central

    Wick, Carson A.; Su, Jin-Jyh; McClellan, James H.; Brand, Oliver; Bhatti, Pamela T.; Buice, Ashley L.; Stillman, Arthur E.; Tang, Xiangyang; Tridandapani, Srini

    2013-01-01

    Seismocardiography (SCG), a representation of mechanical heart motion, may more accurately determine periods of cardiac quiescence within a cardiac cycle than the electrically derived electrocardiogram (EKG) and, thus, may have implications for gating in cardiac computed tomography. We designed and implemented a system to synchronously acquire echocardiography, EKG, and SCG data. The device was used to study the variability between EKG and SCG and characterize the relationship between the mechanical and electrical activity of the heart. For each cardiac cycle, the feature of the SCG indicating Aortic Valve Closure was identified and its time position with respect to the EKG was observed. This position was found to vary for different heart rates and between two human subjects. A color map showing the magnitude of the SCG acceleration and computed velocity was derived, allowing for direct visualization of quiescent phases of the cardiac cycle with respect to heart rate. PMID:22581141

  18. The Utility of Cardiac Magnetic Resonance Imaging in the Diagnosis of Cardiac Sarcoidosis.

    PubMed

    Stanton, Kelly M; Ganigara, Madhusudan; Corte, Peter; Celermajer, David S; McGuire, Mark A; Torzillo, Paul J; Corte, Tamera J; Puranik, Rajesh

    2017-11-01

    Autopsy reports suggest that cardiac sarcoidosis occurs in 20 to 25% of patients with pulmonary sarcoidosis, yet the clinical ante-mortem diagnosis is made in only 5% of cases. Current diagnostic algorithms are complex and lack sensitivity. Cardiac Magnetic Resonance imaging (CMR) provides an opportunity to detect myocardial involvement in sarcoidosis. The aim of this study is to determine the prevalence and clinical significance of late gadolinium enhancement (LGE) on CMR in patients with sarcoidosis. Consecutive patients with biopsy-proven sarcoidosis undergoing CMR were retrospectively evaluated for cardiac sarcoidosis. Medical records were correlated with CMR. Forty-six patients were evaluated. Late gadolinium enhancement was present in 22%, indicating myocardial involvement, and 70% had corresponding hyper-intense T2 signal indicating active inflammation. Late gadolinium enhancement was 18%+/-9.7% of overall left ventricular (LV) mass and most commonly located in the basal to mid septum. There was no association between LGE and cardiovascular symptoms or pulmonary stage. Eighty per cent of patients with LGE did not fulfill conventional diagnostic criteria for cardiac sarcoidosis. However, LGE was associated with clinically significant arrhythmia (p<0.01) and a lower LVEF (p=0.04). Using CMR, we identified a higher prevalence of cardiac sarcoidosis than previously reported clinical studies, a prevalence which is more consistent with autopsy data. The presence of LGE was highly correlated with clinically significant arrhythmias and lower LVEF. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). All rights reserved.

  19. Imaging cardiac extracellular matrices: a blueprint for regeneration

    PubMed Central

    Jung, Jangwook P.; Squirrell, Jayne M.; Lyons, Gary E.; Eliceiri, Kevin W.; Ogle, Brenda M.

    2013-01-01

    Once damaged, cardiac tissue does not readily repair and is therefore a primary target of regenerative therapies. One regenerative approach is the development of scaffolds that functionally mimic the cardiac extracellular matrix (ECM) to deliver stem cells or cardiac precursor populations to the heart. Technological advances in micro/nanotechnology, stem cell biology, biomaterials and tissue decellularization have propelled this promising approach forward. Surprisingly, technological advances in optical imaging methods have not been fully utilized in the field of cardiac regeneration. Here, we describe and provide examples to demonstrate how advanced imaging techniques could revolutionize how ECM-mimicking cardiac tissues are informed and evaluated. PMID:22209562

  20. An integrated platform for image-guided cardiac resynchronization therapy

    NASA Astrophysics Data System (ADS)

    Ma, Ying Liang; Shetty, Anoop K.; Duckett, Simon; Etyngier, Patrick; Gijsbers, Geert; Bullens, Roland; Schaeffter, Tobias; Razavi, Reza; Rinaldi, Christopher A.; Rhode, Kawal S.

    2012-05-01

    Cardiac resynchronization therapy (CRT) is an effective procedure for patients with heart failure but 30% of patients do not respond. This may be due to sub-optimal placement of the left ventricular (LV) lead. It is hypothesized that the use of cardiac anatomy, myocardial scar distribution and dyssynchrony information, derived from cardiac magnetic resonance imaging (MRI), may improve outcome by guiding the physician for optimal LV lead positioning. Whole heart MR data can be processed to yield detailed anatomical models including the coronary veins. Cine MR data can be used to measure the motion of the LV to determine which regions are late-activating. Finally, delayed Gadolinium enhancement imaging can be used to detect regions of scarring. This paper presents a complete platform for the guidance of CRT using pre-procedural MR data combined with live x-ray fluoroscopy. The platform was used for 21 patients undergoing CRT in a standard catheterization laboratory. The patients underwent cardiac MRI prior to their procedure. For each patient, a MRI-derived cardiac model, showing the LV lead targets, was registered to x-ray fluoroscopy using multiple views of a catheter looped in the right atrium. Registration was maintained throughout the procedure by a combination of C-arm/x-ray table tracking and respiratory motion compensation. Validation of the registration between the three-dimensional (3D) roadmap and the 2D x-ray images was performed using balloon occlusion coronary venograms. A 2D registration error of 1.2 ± 0.7 mm was achieved. In addition, a novel navigation technique was developed, called Cardiac Unfold, where an entire cardiac chamber is unfolded from 3D to 2D along with all relevant anatomical and functional information and coupled to real-time device detection. This allowed more intuitive navigation as the entire 3D scene was displayed simultaneously on a 2D plot. The accuracy of the unfold navigation was assessed off-line using 13 patient data sets by computing the registration error of the LV pacing lead electrodes which was found to be 2.2 ± 0.9 mm. Furthermore, the use of Unfold Navigation was demonstrated in real-time for four clinical cases.

  1. Beyond fitness tracking: The use of consumer-grade wearable data from normal volunteers in cardiovascular and lipidomics research

    PubMed Central

    Teo, Jing Xian; Yang, Chengxi; Pua, Chee Jian; Blöcker, Christopher; Lim, Jing Quan; Ching, Jianhong; Yap, Jonathan Jiunn Liang; Tan, Swee Yaw; Sahlén, Anders; Chin, Calvin Woon-Loong; Teh, Bin Tean; Rozen, Steven G.; Cook, Stuart Alexander; Yeo, Khung Keong; Tan, Patrick

    2018-01-01

    The use of consumer-grade wearables for purposes beyond fitness tracking has not been comprehensively explored. We generated and analyzed multidimensional data from 233 normal volunteers, integrating wearable data, lifestyle questionnaires, cardiac imaging, sphingolipid profiling, and multiple clinical-grade cardiovascular and metabolic disease markers. We show that subjects can be stratified into distinct clusters based on daily activity patterns and that these clusters are marked by distinct demographic and behavioral patterns. While resting heart rates (RHRs) performed better than step counts in being associated with cardiovascular and metabolic disease markers, step counts identified relationships between physical activity and cardiac remodeling, suggesting that wearable data may play a role in reducing overdiagnosis of cardiac hypertrophy or dilatation in active individuals. Wearable-derived activity levels can be used to identify known and novel activity-modulated sphingolipids that are in turn associated with insulin sensitivity. Our findings demonstrate the potential for wearables in biomedical research and personalized health. PMID:29485983

  2. Echocardiography in the Era of Multimodality Cardiovascular Imaging

    PubMed Central

    Shah, Benoy Nalin

    2013-01-01

    Echocardiography remains the most frequently performed cardiac imaging investigation and is an invaluable tool for detailed and accurate evaluation of cardiac structure and function. Echocardiography, nuclear cardiology, cardiac magnetic resonance imaging, and cardiovascular-computed tomography comprise the subspeciality of cardiovascular imaging, and these techniques are often used together for a multimodality, comprehensive assessment of a number of cardiac diseases. This paper provides the general cardiologist and physician with an overview of state-of-the-art modern echocardiography, summarising established indications as well as highlighting advances in stress echocardiography, three-dimensional echocardiography, deformation imaging, and contrast echocardiography. Strengths and limitations of echocardiography are discussed as well as the growing role of real-time three-dimensional echocardiography in the guidance of structural heart interventions in the cardiac catheter laboratory. PMID:23878804

  3. The Potential of Clinical Phenotyping of Heart Failure With Imaging Biomarkers for Guiding Therapies: A Focused Update.

    PubMed

    Sengupta, Partho P; Kramer, Christopher M; Narula, Jagat; Dilsizian, Vasken

    2017-09-01

    The need for noninvasive assessment of cardiac volumes and ejection fraction (EF) ushered in the use of cardiac imaging techniques in heart failure (HF) trials that investigated the roles of pharmacological and device-based therapies. However, in contrast to HF with reduced EF (HFrEF), modern HF pharmacotherapy has not improved outcomes in HF with preserved EF (HFpEF), largely attributed to patient heterogeneity and incomplete understanding of pathophysiological insights underlying the clinical presentations of HFpEF. Modern cardiac imaging methods offer insights into many sets of changes in cardiac tissue structure and function that can precisely link cause with cardiac remodeling at organ and tissue levels to clinical presentations in HF. This has inspired investigators to seek a more comprehensive understanding of HF presentations using imaging techniques. This article summarizes the available evidence regarding the role of cardiac imaging in HF. Furthermore, we discuss the value of cardiac imaging techniques in identifying HF patient subtypes who share similar causes and mechanistic pathways that can be targeted using specific HF therapies. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  4. Extra-cardiac findings in cardiovascular magnetic resonance: what the imaging cardiologist needs to know.

    PubMed

    Rodrigues, Jonathan C L; Lyen, Stephen M; Loughborough, William; Amadu, Antonio Matteo; Baritussio, Anna; Dastidar, Amardeep Ghosh; Manghat, Nathan E; Bucciarelli-Ducci, Chiara

    2016-05-09

    Cardiovascular magnetic resonance (CMR) is an established non-invasive technique to comprehensively assess cardiovascular structure and function in a variety of acquired and inherited cardiac conditions. A significant amount of the neck, thorax and upper abdomen are imaged at the time of routine clinical CMR, particularly in the initial multi-slice axial and coronal images. The discovery of unsuspected disease at the time of imaging has ethical, financial and medico-legal implications. Extra-cardiac findings at the time of CMR are common, can be important and can change clinical management. Certain patient groups undergoing CMR are at particular risk of important extra-cardiac findings as several of the cardiovascular risk factors for atherosclerosis are also risk factors for malignancy. Furthermore, the presence of certain extra-cardiac findings may contribute to the interpretation of the primary cardiac pathology as some cardiac conditions have multi-systemic extra-cardiac involvement. The aim of this review is to give an overview of the type of extra-cardiac findings that may become apparent on CMR, subdivided by anatomical location. We focus on normal variant anatomy that may mimic disease, common incidental extra-cardiac findings and important imaging signs that help distinguish sinister pathology from benign disease. We also aim to provide a framework to the approach and potential further diagnostic work-up of incidental extra-cardiac findings discovered at the time of CMR. However, it is beyond the scope of this review to discuss and determine the clinical significance of extracardiac findings at CMR.

  5. ADAPTIVE REAL-TIME CARDIAC MRI USING PARADISE: VALIDATION BY THE PHYSIOLOGICALLY IMPROVED NCAT PHANTOM

    PubMed Central

    Sharif, Behzad; Bresler, Yoram

    2013-01-01

    Patient-Adaptive Reconstruction and Acquisition Dynamic Imaging with Sensitivity Encoding (PARADISE) is a dynamic MR imaging scheme that optimally combines parallel imaging and model-based adaptive acquisition. In this work, we propose the application of PARADISE to real-time cardiac MRI. We introduce a physiologically improved version of a realistic four-dimensional cardiac-torso (NCAT) phantom, which incorporates natural beat-to-beat heart rate and motion variations. Cardiac cine imaging using PARADISE is simulated and its performance is analyzed by virtue of the improved phantom. Results verify the effectiveness of PARADISE for high resolution un-gated real-time cardiac MRI and its superiority over conventional acquisition methods. PMID:24398475

  6. Single-shot turbo spin echo acquisition for in vivo cardiac diffusion MRI.

    PubMed

    Edalati, Masoud; Lee, Gregory R; Hui Wang; Taylor, Michael D; Li, Yu Y

    2016-08-01

    Diffusion MRI offers the ability to noninvasively characterize the microstructure of myocardium tissue and detect disease related pathology in cardiovascular examination. This study investigates the feasibility of in vivo cardiac diffusion MRI under free-breathing condition. A high-speed imaging technique, correlation imaging, is used to enable single-shot turbo spin echo for free-breathing cardiac data acquisition. The obtained in vivo cardiac diffusion-weighted images illustrate robust image quality and minor geometry distortions. The resultant diffusion scalar maps show reliable quantitative values consistent with those previously published in the literature. It is demonstrated that this technique has the potential for in vivo free-breathing cardiac diffusion MRI.

  7. Congenital and hereditary causes of sudden cardiac death in young adults: diagnosis, differential diagnosis, and risk stratification.

    PubMed

    Stojanovska, Jadranka; Garg, Anubhav; Patel, Smita; Melville, David M; Kazerooni, Ella A; Mueller, Gisela C

    2013-01-01

    Sudden cardiac death is defined as death from unexpected circulatory arrest-usually a result of cardiac arrhythmia-that occurs within 1 hour of the onset of symptoms. Proper and timely identification of individuals at risk for sudden cardiac death and the diagnosis of its predisposing conditions are vital. A careful history and physical examination, in addition to electrocardiography and cardiac imaging, are essential to identify conditions associated with sudden cardiac death. Among young adults (18-35 years), sudden cardiac death most commonly results from a previously undiagnosed congenital or hereditary condition, such as coronary artery anomalies and inherited cardiomyopathies (eg, hypertrophic cardiomyopathy, arrhythmogenic right ventricular cardiomyopathy [ARVC], dilated cardiomyopathy, and noncompaction cardiomyopathy). Overall, the most common causes of sudden cardiac death in young adults are, in descending order of frequency, hypertrophic cardiomyopathy, coronary artery anomalies with an interarterial or intramural course, and ARVC. Often, sudden cardiac death is precipitated by ventricular tachycardia or fibrillation and may be prevented with an implantable cardioverter defibrillator (ICD). Risk stratification to determine the need for an ICD is challenging and involves imaging, particularly echocardiography and cardiac magnetic resonance (MR) imaging. Coronary artery anomalies, a diverse group of congenital disorders with a variable manifestation, may be depicted at coronary computed tomographic angiography or MR angiography. A thorough understanding of clinical risk stratification, imaging features, and complementary diagnostic tools for the evaluation of cardiac disorders that may lead to sudden cardiac death is essential to effectively use imaging to guide diagnosis and therapy.

  8. Direct reconstruction of cardiac PET kinetic parametric images using a preconditioned conjugate gradient approach

    PubMed Central

    Rakvongthai, Yothin; Ouyang, Jinsong; Guerin, Bastien; Li, Quanzheng; Alpert, Nathaniel M.; El Fakhri, Georges

    2013-01-01

    Purpose: Our research goal is to develop an algorithm to reconstruct cardiac positron emission tomography (PET) kinetic parametric images directly from sinograms and compare its performance with the conventional indirect approach. Methods: Time activity curves of a NCAT phantom were computed according to a one-tissue compartmental kinetic model with realistic kinetic parameters. The sinograms at each time frame were simulated using the activity distribution for the time frame. The authors reconstructed the parametric images directly from the sinograms by optimizing a cost function, which included the Poisson log-likelihood and a spatial regularization terms, using the preconditioned conjugate gradient (PCG) algorithm with the proposed preconditioner. The proposed preconditioner is a diagonal matrix whose diagonal entries are the ratio of the parameter and the sensitivity of the radioactivity associated with parameter. The authors compared the reconstructed parametric images using the direct approach with those reconstructed using the conventional indirect approach. Results: At the same bias, the direct approach yielded significant relative reduction in standard deviation by 12%–29% and 32%–70% for 50 × 106 and 10 × 106 detected coincidences counts, respectively. Also, the PCG method effectively reached a constant value after only 10 iterations (with numerical convergence achieved after 40–50 iterations), while more than 500 iterations were needed for CG. Conclusions: The authors have developed a novel approach based on the PCG algorithm to directly reconstruct cardiac PET parametric images from sinograms, and yield better estimation of kinetic parameters than the conventional indirect approach, i.e., curve fitting of reconstructed images. The PCG method increases the convergence rate of reconstruction significantly as compared to the conventional CG method. PMID:24089922

  9. Direct reconstruction of cardiac PET kinetic parametric images using a preconditioned conjugate gradient approach.

    PubMed

    Rakvongthai, Yothin; Ouyang, Jinsong; Guerin, Bastien; Li, Quanzheng; Alpert, Nathaniel M; El Fakhri, Georges

    2013-10-01

    Our research goal is to develop an algorithm to reconstruct cardiac positron emission tomography (PET) kinetic parametric images directly from sinograms and compare its performance with the conventional indirect approach. Time activity curves of a NCAT phantom were computed according to a one-tissue compartmental kinetic model with realistic kinetic parameters. The sinograms at each time frame were simulated using the activity distribution for the time frame. The authors reconstructed the parametric images directly from the sinograms by optimizing a cost function, which included the Poisson log-likelihood and a spatial regularization terms, using the preconditioned conjugate gradient (PCG) algorithm with the proposed preconditioner. The proposed preconditioner is a diagonal matrix whose diagonal entries are the ratio of the parameter and the sensitivity of the radioactivity associated with parameter. The authors compared the reconstructed parametric images using the direct approach with those reconstructed using the conventional indirect approach. At the same bias, the direct approach yielded significant relative reduction in standard deviation by 12%-29% and 32%-70% for 50 × 10(6) and 10 × 10(6) detected coincidences counts, respectively. Also, the PCG method effectively reached a constant value after only 10 iterations (with numerical convergence achieved after 40-50 iterations), while more than 500 iterations were needed for CG. The authors have developed a novel approach based on the PCG algorithm to directly reconstruct cardiac PET parametric images from sinograms, and yield better estimation of kinetic parameters than the conventional indirect approach, i.e., curve fitting of reconstructed images. The PCG method increases the convergence rate of reconstruction significantly as compared to the conventional CG method.

  10. Simulation study on compressive laminar optical tomography for cardiac action potential propagation

    PubMed Central

    Harada, Takumi; Tomii, Naoki; Manago, Shota; Kobayashi, Etsuko; Sakuma, Ichiro

    2017-01-01

    To measure the activity of tissue at the microscopic level, laminar optical tomography (LOT), which is a microscopic form of diffuse optical tomography, has been developed. However, obtaining sufficient recording speed to determine rapidly changing dynamic activity remains major challenges. For a high frame rate of the reconstructed data, we here propose a new LOT method using compressed sensing theory, called compressive laminar optical tomography (CLOT), in which novel digital micromirror device-based illumination and data reduction in a single reconstruction are applied. In the simulation experiments, the reconstructed volumetric images of the action potentials that were acquired from 5 measured images with random pattern featured a wave border at least to a depth of 2.5 mm. Consequently, it was shown that CLOT has potential for over 200 fps required for the cardiac electrophysiological phenomena. PMID:28736675

  11. Performance evaluation of the Ingenuity TF PET/CT scanner with a focus on high count-rate conditions

    NASA Astrophysics Data System (ADS)

    Kolthammer, Jeffrey A.; Su, Kuan-Hao; Grover, Anu; Narayanan, Manoj; Jordan, David W.; Muzic, Raymond F.

    2014-07-01

    This study evaluated the positron emission tomography (PET) imaging performance of the Ingenuity TF 128 PET/computed tomography (CT) scanner which has a PET component that was designed to support a wider radioactivity range than is possible with those of Gemini TF PET/CT and Ingenuity TF PET/MR. Spatial resolution, sensitivity, count rate characteristics and image quality were evaluated according to the NEMA NU 2-2007 standard and ACR phantom accreditation procedures; these were supplemented by additional measurements intended to characterize the system under conditions that would be encountered during quantitative cardiac imaging with 82Rb. Image quality was evaluated using a hot spheres phantom, and various contrast recovery and noise measurements were made from replicated images. Timing and energy resolution, dead time, and the linearity of the image activity concentration, were all measured over a wide range of count rates. Spatial resolution (4.8-5.1 mm FWHM), sensitivity (7.3 cps kBq-1), peak noise-equivalent count rate (124 kcps), and peak trues rate (365 kcps) were similar to those of the Gemini TF PET/CT. Contrast recovery was higher with a 2 mm, body-detail reconstruction than with a 4 mm, body reconstruction, although the precision was reduced. The noise equivalent count rate peak was broad (within 10% of peak from 241-609 MBq). The activity measured in phantom images was within 10% of the true activity for count rates up to those observed in 82Rb cardiac PET studies.

  12. Subcutaneous Tissue Thickness is an Independent Predictor of Image Noise in Cardiac CT

    PubMed Central

    Staniak, Henrique Lane; Sharovsky, Rodolfo; Pereira, Alexandre Costa; de Castro, Cláudio Campi; Benseñor, Isabela M.; Lotufo, Paulo A.; Bittencourt, Márcio Sommer

    2014-01-01

    Background Few data on the definition of simple robust parameters to predict image noise in cardiac computed tomography (CT) exist. Objectives To evaluate the value of a simple measure of subcutaneous tissue as a predictor of image noise in cardiac CT. Methods 86 patients underwent prospective ECG-gated coronary computed tomographic angiography (CTA) and coronary calcium scoring (CAC) with 120 kV and 150 mA. The image quality was objectively measured by the image noise in the aorta in the cardiac CTA, and low noise was defined as noise < 30HU. The chest anteroposterior diameter and lateral width, the image noise in the aorta and the skin-sternum (SS) thickness were measured as predictors of cardiac CTA noise. The association of the predictors and image noise was performed by using Pearson correlation. Results The mean radiation dose was 3.5 ± 1.5 mSv. The mean image noise in CT was 36.3 ± 8.5 HU, and the mean image noise in non-contrast scan was 17.7 ± 4.4 HU. All predictors were independently associated with cardiac CTA noise. The best predictors were SS thickness, with a correlation of 0.70 (p < 0.001), and noise in the non-contrast images, with a correlation of 0.73 (p < 0.001). When evaluating the ability to predict low image noise, the areas under the ROC curve for the non-contrast noise and for the SS thickness were 0.837 and 0.864, respectively. Conclusion Both SS thickness and CAC noise are simple accurate predictors of cardiac CTA image noise. Those parameters can be incorporated in standard CT protocols to adequately adjust radiation exposure. PMID:24173136

  13. Robust temporal alignment of multimodal cardiac sequences

    NASA Astrophysics Data System (ADS)

    Perissinotto, Andrea; Queirós, Sandro; Morais, Pedro; Baptista, Maria J.; Monaghan, Mark; Rodrigues, Nuno F.; D'hooge, Jan; Vilaça, João. L.; Barbosa, Daniel

    2015-03-01

    Given the dynamic nature of cardiac function, correct temporal alignment of pre-operative models and intraoperative images is crucial for augmented reality in cardiac image-guided interventions. As such, the current study focuses on the development of an image-based strategy for temporal alignment of multimodal cardiac imaging sequences, such as cine Magnetic Resonance Imaging (MRI) or 3D Ultrasound (US). First, we derive a robust, modality-independent signal from the image sequences, estimated by computing the normalized cross-correlation between each frame in the temporal sequence and the end-diastolic frame. This signal is a resembler for the left-ventricle (LV) volume curve over time, whose variation indicates different temporal landmarks of the cardiac cycle. We then perform the temporal alignment of these surrogate signals derived from MRI and US sequences of the same patient through Dynamic Time Warping (DTW), allowing to synchronize both sequences. The proposed framework was evaluated in 98 patients, which have undergone both 3D+t MRI and US scans. The end-systolic frame could be accurately estimated as the minimum of the image-derived surrogate signal, presenting a relative error of 1.6 +/- 1.9% and 4.0 +/- 4.2% for the MRI and US sequences, respectively, thus supporting its association with key temporal instants of the cardiac cycle. The use of DTW reduces the desynchronization of the cardiac events in MRI and US sequences, allowing to temporally align multimodal cardiac imaging sequences. Overall, a generic, fast and accurate method for temporal synchronization of MRI and US sequences of the same patient was introduced. This approach could be straightforwardly used for the correct temporal alignment of pre-operative MRI information and intra-operative US images.

  14. Low-Cost Optical Mapping Systems for Panoramic Imaging of Complex Arrhythmias and Drug-Action in Translational Heart Models

    NASA Astrophysics Data System (ADS)

    Lee, Peter; Calvo, Conrado J.; Alfonso-Almazán, José M.; Quintanilla, Jorge G.; Chorro, Francisco J.; Yan, Ping; Loew, Leslie M.; Filgueiras-Rama, David; Millet, José

    2017-02-01

    Panoramic optical mapping is the primary method for imaging electrophysiological activity from the entire outer surface of Langendorff-perfused hearts. To date, it is the only method of simultaneously measuring multiple key electrophysiological parameters, such as transmembrane voltage and intracellular free calcium, at high spatial and temporal resolution. Despite the impact it has already had on the fields of cardiac arrhythmias and whole-heart computational modeling, present-day system designs precludes its adoption by the broader cardiovascular research community because of their high costs. Taking advantage of recent technological advances, we developed and validated low-cost optical mapping systems for panoramic imaging using Langendorff-perfused pig hearts, a clinically-relevant model in basic research and bioengineering. By significantly lowering financial thresholds, this powerful cardiac electrophysiology imaging modality may gain wider use in research and, even, teaching laboratories, which we substantiated using the lower-cost Langendorff-perfused rabbit heart model.

  15. Low-Cost Optical Mapping Systems for Panoramic Imaging of Complex Arrhythmias and Drug-Action in Translational Heart Models.

    PubMed

    Lee, Peter; Calvo, Conrado J; Alfonso-Almazán, José M; Quintanilla, Jorge G; Chorro, Francisco J; Yan, Ping; Loew, Leslie M; Filgueiras-Rama, David; Millet, José

    2017-02-27

    Panoramic optical mapping is the primary method for imaging electrophysiological activity from the entire outer surface of Langendorff-perfused hearts. To date, it is the only method of simultaneously measuring multiple key electrophysiological parameters, such as transmembrane voltage and intracellular free calcium, at high spatial and temporal resolution. Despite the impact it has already had on the fields of cardiac arrhythmias and whole-heart computational modeling, present-day system designs precludes its adoption by the broader cardiovascular research community because of their high costs. Taking advantage of recent technological advances, we developed and validated low-cost optical mapping systems for panoramic imaging using Langendorff-perfused pig hearts, a clinically-relevant model in basic research and bioengineering. By significantly lowering financial thresholds, this powerful cardiac electrophysiology imaging modality may gain wider use in research and, even, teaching laboratories, which we substantiated using the lower-cost Langendorff-perfused rabbit heart model.

  16. Cardiac fluid dynamics meets deformation imaging.

    PubMed

    Dal Ferro, Matteo; Stolfo, Davide; De Paris, Valerio; Lesizza, Pierluigi; Korcova, Renata; Collia, Dario; Tonti, Giovanni; Sinagra, Gianfranco; Pedrizzetti, Gianni

    2018-02-20

    Cardiac function is about creating and sustaining blood in motion. This is achieved through a proper sequence of myocardial deformation whose final goal is that of creating flow. Deformation imaging provided valuable contributions to understanding cardiac mechanics; more recently, several studies evidenced the existence of an intimate relationship between cardiac function and intra-ventricular fluid dynamics. This paper summarizes the recent advances in cardiac flow evaluations, highlighting its relationship with heart wall mechanics assessed through the newest techniques of deformation imaging and finally providing an opinion of the most promising clinical perspectives of this emerging field. It will be shown how fluid dynamics can integrate volumetric and deformation assessments to provide a further level of knowledge of cardiac mechanics.

  17. Image-Based Predictive Modeling of Heart Mechanics.

    PubMed

    Wang, V Y; Nielsen, P M F; Nash, M P

    2015-01-01

    Personalized biophysical modeling of the heart is a useful approach for noninvasively analyzing and predicting in vivo cardiac mechanics. Three main developments support this style of analysis: state-of-the-art cardiac imaging technologies, modern computational infrastructure, and advanced mathematical modeling techniques. In vivo measurements of cardiac structure and function can be integrated using sophisticated computational methods to investigate mechanisms of myocardial function and dysfunction, and can aid in clinical diagnosis and developing personalized treatment. In this article, we review the state-of-the-art in cardiac imaging modalities, model-based interpretation of 3D images of cardiac structure and function, and recent advances in modeling that allow personalized predictions of heart mechanics. We discuss how using such image-based modeling frameworks can increase the understanding of the fundamental biophysics behind cardiac mechanics, and assist with diagnosis, surgical guidance, and treatment planning. Addressing the challenges in this field will require a coordinated effort from both the clinical-imaging and modeling communities. We also discuss future directions that can be taken to bridge the gap between basic science and clinical translation.

  18. Using cardiovascular imaging modalities to determine cardiac disorders before starting sports activities.

    PubMed

    Ceylan, Özgür; Meşe, Timur; Gürsu, Alper Hazım

    2017-03-01

    We re-examined children who had previously been declared eligible to participate in competitive sports activities for cardiac disorders, using cardiac investigation protocol. Total of 250 children (224 males [89.6%], and 26 females [10.4%]) between the ages of 8 and 17 years who had just started or were already engaged in sports activities were included in the study. Participants had detailed physical examination evaluated by a pediatric cardiologist. Those with findings suggesting cardiac disorder in their history and/or physical examinations, and/or 12-channel electrocardiography (ECG) were examined with echocardiography (ECHO), 24-hour Holter monitoring, and exercise test. Mean duration of participation in sports activities was 13 months. Among all, 10.4% of the children had abnormalities on ECG. ECHO demonstrated cardiomyopathy in 1, mitral valve prolapse in 2, tricuspid insufficiency in 2, and mitral insufficiency in 1 participant. Holter monitoring revealed non-sustained ventricular tachycardia attacks in 1, and supraventricular tachycardia in another child. Three were ultimately disqualified from partaking in competitive sports. Sports and medical communities must work together to establish study protocols to prevent sudden death related to sports and to make these activities safer for athletes. Pediatric cardiology consultation for young athletes before they start sports activities is needed.

  19. Achieving high-value cardiac imaging: challenges and opportunities.

    PubMed

    Wiener, David H

    2014-01-01

    Cardiac imaging is under intense scrutiny as a contributor to health care costs, with multiple initiatives under way to reduce and eliminate inappropriate testing. Appropriate use criteria are valuable guides to selecting imaging studies but until recently have focused on the test rather than the patient. Patient-centered means are needed to define the true value of imaging for patients in specific clinical situations. This article provides a definition of high-value cardiac imaging. A paradigm to judge the efficacy of echocardiography in the absence of randomized controlled trials is presented. Candidate clinical scenarios are proposed in which echocardiography constitutes high-value imaging, as well as stratagems to increase the likelihood that high-value cardiac imaging takes place in those circumstances. Copyright © 2014 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

  20. Computer simulation comparison of tripolar, bipolar, and spline Laplacian electrocadiogram estimators.

    PubMed

    Chen, T; Besio, W; Dai, W

    2009-01-01

    A comparison of the performance of the tripolar and bipolar concentric as well as spline Laplacian electrocardiograms (LECGs) and body surface Laplacian mappings (BSLMs) for localizing and imaging the cardiac electrical activation has been investigated based on computer simulation. In the simulation a simplified eccentric heart-torso sphere-cylinder homogeneous volume conductor model were developed. Multiple dipoles with different orientations were used to simulate the underlying cardiac electrical activities. Results show that the tripolar concentric ring electrodes produce the most accurate LECG and BSLM estimation among the three estimators with the best performance in spatial resolution.

  1. Identification of Location Specific Feature Points in a Cardiac Cycle Using a Novel Seismocardiogram Spectrum System.

    PubMed

    Lin, Wen-Yen; Chou, Wen-Cheng; Chang, Po-Cheng; Chou, Chung-Chuan; Wen, Ming-Shien; Ho, Ming-Yun; Lee, Wen-Chen; Hsieh, Ming-Jer; Lin, Chung-Chih; Tsai, Tsai-Hsuan; Lee, Ming-Yih

    2018-03-01

    Seismocardiogram (SCG) or mechanocardiography is a noninvasive cardiac diagnostic method; however, previous studies used only a single sensor to detect cardiac mechanical activities that will not be able to identify location-specific feature points in a cardiac cycle corresponding to the four valvular auscultation locations. In this study, a multichannel SCG spectrum measurement system was proposed and examined for cardiac activity monitoring to overcome problems like, position dependency, time delay, and signal attenuation, occurring in traditional single-channel SCG systems. ECG and multichannel SCG signals were simultaneously recorded in 25 healthy subjects. Cardiac echocardiography was conducted at the same time. SCG traces were analyzed and compared with echocardiographic images for feature point identification. Fifteen feature points were identified in the corresponding SCG traces. Among them, six feature points, including left ventricular lateral wall contraction peak velocity, septal wall contraction peak velocity, transaortic peak flow, transpulmonary peak flow, transmitral ventricular relaxation flow, and transmitral atrial contraction flow were identified. These new feature points were not observed in previous studies because the single-channel SCG could not detect the location-specific signals from other locations due to time delay and signal attenuation. As the results, the multichannel SCG spectrum measurement system can record the corresponding cardiac mechanical activities with location-specific SCG signals and six new feature points were identified with the system. This new modality may help clinical diagnoses of valvular heart diseases and heart failure in the future.

  2. The Future of Cardiac Imaging: Report of a Think Tank Convened by the American College of Cardiology.

    PubMed

    Douglas, Pamela S; Cerqueira, Manuel D; Berman, Daniel S; Chinnaiyan, Kavitha; Cohen, Meryl S; Lundbye, Justin B; Patel, Rajan A G; Sengupta, Partho P; Soman, Prem; Weissman, Neil J; Wong, Timothy C

    2016-10-01

    The American College of Cardiology's Executive Committee and Cardiovascular Imaging Section Leadership Council convened a discussion regarding the future of cardiac imaging among thought leaders in the field during a 2 day Think Tank. Participants were charged with thinking broadly about the future of imaging and developing a roadmap to address critical challenges. Key areas of discussion included: 1) how can cardiac imaging services thrive in our new world of value-based health care? 2) Who is the cardiac imager of the future and what is the role of the multimodality imager? 3) How can we nurture innovation and research in imaging? And 4) how can we maximize imaging information and optimize outcomes? This document describes the proceedings of this Think Tank. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. ACR-SPR-STR Practice Parameter for the Performance of Cardiac Positron Emission Tomography - Computed Tomography (PET/CT) Imaging.

    PubMed

    Subramaniam, Rathan M; Janowitz, Warren R; Johnson, Geoffrey B; Lodge, Martin A; Parisi, Marguerite T; Ferguson, Mark R; Hellinger, Jeffrey C; Gladish, Gregory W; Gupta, Narainder K

    2017-12-01

    This clinical practice parameter has been developed collaboratively by the American College of Radiology (ACR), the Society for Pediatric Radiology (SPR), and the Society of Thoracic Radiology (STR). This document is intended to act as a guide for physicians performing and interpreting positron emission tomography-computed tomography (PET/CT) of cardiac diseases in adults and children. The primary value of cardiac PET/CT imaging include evaluation of perfusion, function, viability, inflammation, anatomy, and risk stratification for cardiac-related events such as myocardial infarction and death. Optimum utility of cardiac PET/CT is achieved when images are interpreted in conjunction with clinical information and laboratory data. Measurement of myocardial blood flow, coronary flow reserve and detection of balanced ischemia are significant advantages of cardiac PET perfusion studies. Increasingly cardiac PET/CT is used in diagnosis and treatment response assessment for cardiac sarcoidosis.

  4. Contribution of cardiac-induced brain pulsation to the noise of the diffusion tensor in Turboprop diffusion tensor imaging (DTI).

    PubMed

    Gui, Minzhi; Tamhane, Ashish A; Arfanakis, Konstantinos

    2008-05-01

    To assess the effects of cardiac-induced brain pulsation on the noise of the diffusion tensor in Turboprop (a form of periodically rotated overlapping parallel lines with enhanced reconstruction [PROPELLER] imaging) diffusion tensor imaging (DTI). A total of six healthy human subjects were imaged with cardiac-gated as well as nongated Turboprop DTI. Gated and nongated Turboprop DTI datasets were also simulated using actual data acquired exclusively during the diastolic or systolic period of the cardiac cycle. The total variance of the diffusion tensor (TVDT) was measured and compared between acquisitions. The TVDT near the ventricles was significantly reduced in cardiac-gated compared to nongated Turboprop DTI acquisitions. Furthermore, the effects of brain pulsation were reduced, but not eliminated, when increasing the amount of data collected. Finally, data corrupted by cardiac-induced pulsation were not consistently detected by the step of the conventional Turboprop reconstruction algorithm that evaluates the quality of data in different blades. Thus, the inherent quality weighting of the conventional Turboprop reconstruction algorithm was unable to compensate for the increased noise in the diffusion tensor due to brain pulsation. Cardiac-induced brain pulsation increases the TVDT in Turboprop DTI. Use of cardiac gating to limit data acquisition to the diastolic period of the cardiac cycle reduces the TVDT at the expense of imaging time. (c) 2008 Wiley-Liss, Inc.

  5. Technical aspects of cardiac PET/MRI.

    PubMed

    Masuda, Atsuro; Nemoto, Ayaka; Takeishi, Yasuchika

    2018-06-01

    PET/MRI is a novel modality that enables to combine PET and MR images, and has significant potential to evaluate various cardiac diseases through the combination of PET molecular imaging and MRI functional imaging. Precise management of technical issues, however, is necessary for cardiac PET/MRI. This article describes several technical points, including patient preparation, MR attenuation correction, parallel acquisition of PET with MRI, clinical aspects, and image quality control.

  6. Analytically based photon scatter modeling for a multipinhole cardiac SPECT camera.

    PubMed

    Pourmoghaddas, Amir; Wells, R Glenn

    2016-11-01

    Dedicated cardiac SPECT scanners have improved performance over standard gamma cameras allowing reductions in acquisition times and/or injected activity. One approach to improving performance has been to use pinhole collimators, but this can cause position-dependent variations in attenuation, sensitivity, and spatial resolution. CT attenuation correction (AC) and an accurate system model can compensate for many of these effects; however, scatter correction (SC) remains an outstanding issue. In addition, in cameras using cadmium-zinc-telluride-based detectors, a large portion of unscattered photons is detected with reduced energy (low-energy tail). Consequently, application of energy-based SC approaches in these cameras leads to a higher increase in noise than with standard cameras due to the subtraction of true counts detected in the low-energy tail. Model-based approaches with parallel-hole collimator systems accurately calculate scatter based on the physics of photon interactions in the patient and camera and generate lower-noise estimates of scatter than energy-based SC. In this study, the accuracy of a model-based SC method was assessed using physical phantom studies on the GE-Discovery NM530c and its performance was compared to a dual energy window (DEW)-SC method. The analytical photon distribution (APD) method was used to calculate the distribution of probabilities that emitted photons will scatter in the surrounding scattering medium and be subsequently detected. APD scatter calculations for 99m Tc-SPECT (140 ± 14 keV) were validated with point-source measurements and 15 anthropomorphic cardiac-torso phantom experiments and varying levels of extra-cardiac activity causing scatter inside the heart. The activity inserted into the myocardial compartment of the phantom was first measured using a dose calibrator. CT images were acquired on an Infinia Hawkeye (GE Healthcare) SPECT/CT and coregistered with emission data for AC. For comparison, DEW scatter projections (120 ± 6 keV ) were also extracted from the acquired list-mode SPECT data. Either APD or DEW scatter projections were subtracted from corresponding 140 keV measured projections and then reconstructed with AC (APD-SC and DEW-SC). Quantitative accuracy of the activity measured in the heart for the APD-SC and DEW-SC images was assessed against dose calibrator measurements. The difference between modeled and acquired projections was measured as the root-mean-squared-error (RMSE). APD-modeled projections for a clinical cardiac study were also evaluated. APD-modeled projections showed good agreement with SPECT measurements and had reduced noise compared to DEW scatter estimates. APD-SC reduced mean error in activity measurement compared to DEW-SC in images and the reduction was statistically significant where the scatter fraction (SF) was large (mean SF = 28.5%, T-test p = 0.007). APD-SC reduced measurement uncertainties as well; however, the difference was not found to be statistically significant (F-test p > 0.5). RMSE comparisons showed that elevated levels of scatter did not significantly contribute to a change in RMSE (p > 0.2). Model-based APD scatter estimation is feasible for dedicated cardiac SPECT scanners with pinhole collimators. APD-SC images performed better than DEW-SC images and improved the accuracy of activity measurement in high-scatter scenarios.

  7. Cirrhotic cardiomyopathy: Implications for the perioperative management of liver transplant patients

    PubMed Central

    Rahman, Suehana; Mallett, Susan V

    2015-01-01

    Cirrhotic cardiomyopathy is a disease that has only recently been recognised as a definitive clinical entity. In the setting of liver cirrhosis, it is characterized by a blunted inotropic and chronotropic response to stress, impaired diastolic relaxation of the myocardium and prolongation of the QT interval in the absence of other known cardiac disease. A key pathological feature is the persistent over-activation of the sympathetic nervous system in cirrhosis, which leads to down-regulation and dysfunction of the β-adrenergic receptor. Diagnosis can be made using a combination of echocardiography (resting and stress), tissue Doppler imaging, cardiac magnetic resonance imaging, 12-lead electrocardiogram and measurement of biomarkers. There are significant implications of cirrhotic cardiomyopathy in a number of clinical situations in which there is an increased physiological demand, which can lead to acute cardiac decompensation and heart failure. Prior to transplantation there is an increased risk of hepatorenal syndrome, cardiac failure following transjugular intrahepatic portosystemic shunt insertion and increased risk of arrhythmias during acute gastrointestinal bleeding. Liver transplantation presents the greatest physiological challenge with a further risk of acute cardiac decompensation. Peri-operative management should involve appropriate choice of graft and minimization of large fluctuations in preload and afterload. The avoidance of cardiac failure during this period has important prognostic implications, as there is evidence to suggest a long-term resolution of the abnormalities in cirrhotic cardiomyopathy. PMID:25848474

  8. PGC-1{alpha} accelerates cytosolic Ca{sup 2+} clearance without disturbing Ca{sup 2+} homeostasis in cardiac myocytes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Min, E-mail: chenminyx@gmail.com; Yunnan Centers for Diseases Prevention and Control, Kunming 650022; Wang, Yanru

    2010-06-11

    Energy metabolism and Ca{sup 2+} handling serve critical roles in cardiac physiology and pathophysiology. Peroxisome proliferator-activated receptor gamma coactivator 1 alpha (PGC-1{alpha}) is a multi-functional coactivator that is involved in the regulation of cardiac mitochondrial functional capacity and cellular energy metabolism. However, the regulation of PGC-1{alpha} in cardiac Ca{sup 2+} signaling has not been fully elucidated. To address this issue, we combined confocal line-scan imaging with off-line imaging processing to characterize calcium signaling in cultured adult rat ventricular myocytes expressing PGC-1{alpha} via adenoviral transduction. Our data shows that overexpressing PGC-1{alpha} improved myocyte contractility without increasing the amplitude of Ca{sup 2+}more » transients, suggesting that myofilament sensitivity to Ca{sup 2+} increased. Interestingly, the decay kinetics of global Ca{sup 2+} transients and Ca{sup 2+} waves accelerated in PGC-1{alpha}-expressing cells, but the decay rate of caffeine-elicited Ca{sup 2+} transients showed no significant change. This suggests that sarcoplasmic reticulum (SR) Ca{sup 2+}-ATPase (SERCA2a), but not Na{sup +}/Ca{sup 2+} exchange (NCX) contribute to PGC-1{alpha}-induced cytosolic Ca{sup 2+} clearance. Furthermore, PGC-1{alpha} induced the expression of SERCA2a in cultured cardiac myocytes. Importantly, overexpressing PGC-1{alpha} did not disturb cardiac Ca{sup 2+} homeostasis, because SR Ca{sup 2+} load and the propensity for Ca{sup 2+} waves remained unchanged. These data suggest that PGC-1{alpha} can ameliorate cardiac Ca{sup 2+} cycling and improve cardiac work output in response to physiological stress. Unraveling the PGC-1{alpha}-calcium handing pathway sheds new light on the role of PGC-1{alpha} in the therapy of cardiac diseases.« less

  9. Activation Time of Cardiac Tissue In Response to a Linear Array of Spatial Alternating Bipolar Electrodes

    NASA Astrophysics Data System (ADS)

    Mashburn, David; Wikswo, John

    2007-11-01

    Prevailing theories about the response of the heart to high field shocks predict that local regions of high resistivity distributed throughout the heart create multiple small virtual electrodes that hyperpolarize or depolarize tissue and lead to widespread activation. This resetting of bulk tissue is responsible for the successful functioning of cardiac defibrillators. By activating cardiac tissue with regular linear arrays of spatially alternating bipolar currents, we can simulate these potentials locally. We have studied the activation time due to distributed currents in both a 1D Beeler-Reuter model and on the surface of the whole heart, varying the strength of each source and the separation between them. By comparison with activation time data from actual field shock of a whole heart in a bath, we hope to better understand these transient virtual electrodes. Our work was done on rabbit RV using florescent optical imaging and our Phased Array Stimulator for driving the 16 current sources. Our model shows that for a total absolute current delivered to a region of tissue, the entire region activates faster if above-threshold sources are more distributed.

  10. AKAP-Lbc mobilizes a cardiac hypertrophy signaling pathway.

    PubMed

    Carnegie, Graeme K; Soughayer, Joseph; Smith, F Donelson; Pedroja, Benjamin S; Zhang, Fang; Diviani, Dario; Bristow, Michael R; Kunkel, Maya T; Newton, Alexandra C; Langeberg, Lorene K; Scott, John D

    2008-10-24

    Elevated catecholamines in the heart evoke transcriptional activation of the Myocyte Enhancer Factor (MEF) pathway to induce a cellular response known as pathological myocardial hypertrophy. We have discovered that the A-Kinase Anchoring Protein (AKAP)-Lbc is upregulated in hypertrophic cardiomyocytes. It coordinates activation and movement of signaling proteins that initiate MEF2-mediated transcriptional reprogramming events. Live-cell imaging, fluorescent kinase activity reporters, and RNA interference techniques show that AKAP-Lbc couples activation of protein kinase D (PKD) with the phosphorylation-dependent nuclear export of the class II histone deacetylase HDAC5. These studies uncover a role for AKAP-Lbc in which increased expression of the anchoring protein selectively amplifies a signaling pathway that drives cardiac myocytes toward a pathophysiological outcome.

  11. F-18 sodium fluoride PET/CT does not effectively image myocardial inflammation due to suspected cardiac sarcoidosis.

    PubMed

    Weinberg, Richard L; Morgenstern, Rachelle; DeLuca, Albert; Chen, Jennifer; Bokhari, Sabahat

    2017-12-01

    Sarcoidosis is an inflammatory disorder of unknown etiology that can involve the heart. While effective in imaging cardiac sarcoidosis, F-18 fluorodeoxyglucose (FDG) PET/CT often shows non-specific myocardial uptake. F-18 sodium fluoride (NaF) has been used to image inflammation in coronary artery plaques and has low background myocardial uptake. Here, we evaluated whether F-18 NaF can image myocardial inflammation due to clinically suspected cardiac sarcoidosis. We performed a single institution pilot study testing if F-18 NaF PET/CT can detect myocardial inflammation in patients with suspected cardiac sarcoidosis. Patients underwent cardiac PET/CT with F-18 FDG as part of their routine care and subsequently received an F-18 NaF PET/CT scan. Three patients underwent F-18 FDG and F-18 NaF imaging. In all patients, there was F-18 FDG uptake consistent with cardiac sarcoidosis. The F-18 NaF PET/CT scans showed no myocardial uptake. In this small preliminary study, PET/CT scan using F-18 NaF does not appear to detect myocardial inflammation caused by suspected cardiac sarcoidosis.

  12. Human torso phantom for imaging of heart with realistic modes of cardiac and respiratory motion

    DOEpatents

    Boutchko, Rostyslav; Balakrishnan, Karthikayan; Gullberg, Grant T; O& #x27; Neil, James P

    2013-09-17

    A human torso phantom and its construction, wherein the phantom mimics respiratory and cardiac cycles in a human allowing acquisition of medical imaging data under conditions simulating patient cardiac and respiratory motion.

  13. Anatomical-based partial volume correction for low-dose dedicated cardiac SPECT/CT

    NASA Astrophysics Data System (ADS)

    Liu, Hui; Chan, Chung; Grobshtein, Yariv; Ma, Tianyu; Liu, Yaqiang; Wang, Shi; Stacy, Mitchel R.; Sinusas, Albert J.; Liu, Chi

    2015-09-01

    Due to the limited spatial resolution, partial volume effect has been a major degrading factor on quantitative accuracy in emission tomography systems. This study aims to investigate the performance of several anatomical-based partial volume correction (PVC) methods for a dedicated cardiac SPECT/CT system (GE Discovery NM/CT 570c) with focused field-of-view over a clinically relevant range of high and low count levels for two different radiotracer distributions. These PVC methods include perturbation geometry transfer matrix (pGTM), pGTM followed by multi-target correction (MTC), pGTM with known concentration in blood pool, the former followed by MTC and our newly proposed methods, which perform the MTC method iteratively, where the mean values in all regions are estimated and updated by the MTC-corrected images each time in the iterative process. The NCAT phantom was simulated for cardiovascular imaging with 99mTc-tetrofosmin, a myocardial perfusion agent, and 99mTc-red blood cell (RBC), a pure intravascular imaging agent. Images were acquired at six different count levels to investigate the performance of PVC methods in both high and low count levels for low-dose applications. We performed two large animal in vivo cardiac imaging experiments following injection of 99mTc-RBC for evaluation of intramyocardial blood volume (IMBV). The simulation results showed our proposed iterative methods provide superior performance than other existing PVC methods in terms of image quality, quantitative accuracy, and reproducibility (standard deviation), particularly for low-count data. The iterative approaches are robust for both 99mTc-tetrofosmin perfusion imaging and 99mTc-RBC imaging of IMBV and blood pool activity even at low count levels. The animal study results indicated the effectiveness of PVC to correct the overestimation of IMBV due to blood pool contamination. In conclusion, the iterative PVC methods can achieve more accurate quantification, particularly for low count cardiac SPECT studies, typically obtained from low-dose protocols, gated studies, and dynamic applications.

  14. Effects of Radiation Exposure From Cardiac Imaging: How Good Are the Data?

    PubMed Central

    Einstein, Andrew J.

    2012-01-01

    Concerns about medical exposure to ionizing radiation have become heightened in recent years due to rapid growth in procedure volumes and the high radiation doses incurred from some procedures. This article summarizes the evidence base undergirding concerns about radiation exposure in cardiac imaging. After classifying radiation effects, explaining terminology used to quantify the radiation received by patients, and describing typical doses from cardiac imaging procedures, I address the major epidemiological studies having bearing on radiation effects at doses comparable to those received by patients undergoing cardiac imaging. These include studies of atomic bomb survivors, nuclear industry workers, and children exposed in utero to x-rays, all of which have evidenced increased cancer risks at low doses. Additional higher dose epidemiological studies of cohorts exposed to radiation in the context of medical treatment are described and found to be generally compatible with these cardiac-dose-level studies, albeit with exceptions. Using risk projection models developed by the US National Academies that incorporate these data and reflect several evidence-based assumptions, cancer risk from cardiac imaging can be estimated and compared to benefits from imaging. Several ongoing epidemiological studies will provide better understanding of radiation-associated cancer risks. PMID:22300689

  15. A Clinical Feasibility Study of Atrial and Ventricular Electromechanical Wave Imaging

    PubMed Central

    Provost, Jean; Gambhir, Alok; Vest, John; Garan, Hasan; Konofagou, Elisa E.

    2014-01-01

    Background Cardiac Resynchronization Therapy (CRT) and atrial ablation currently lack a noninvasive imaging modality for reliable treatment planning and monitoring. Electromechanical Wave Imaging (EWI) is an ultrasound-based method that has previously been shown to be capable of noninvasively and transmurally mapping the activation sequence of the heart in animal studies by estimating and imaging the electromechanical wave, i.e., the transient strains occurring in response to the electrical activation, at both very high temporal and spatial resolution. Objective Demonstrate the feasibility of noninvasive transthoracic EWI for mapping the activation sequence during different cardiac rhythms in humans. Methods EWI was performed in CRT patients with a left bundle-branch block (LBBB), during sinus rhythm, left-ventricular pacing, and right-ventricular pacing and in atrial flutter (AFL) patients before intervention and correlated with results from invasive intracardiac electrical mapping studies during intervention. Additionally, the feasibility of single-heartbeat EWI at 2000 frames/s, is demonstrated in humans for the first time in a subject with both AFL and right bundle-branch-block. Results The electromechanical activation maps demonstrated the capability of EWI to localize the pacing sites and characterize the LBBB activation sequence transmurally in CRT patients. In AFL patients, the propagation patterns obtained with EWI were in agreement with results obtained from invasive intracardiac mapping studies. Conclusion Our findings demonstrate the potential capability of EWI to aid in monitoring and follow-up of patients undergoing CRT pacing therapy and atrial ablation with preliminary validation in vivo. PMID:23454060

  16. AFFINE-CORRECTED PARADISE: FREE-BREATHING PATIENT-ADAPTIVE CARDIAC MRI WITH SENSITIVITY ENCODING

    PubMed Central

    Sharif, Behzad; Bresler, Yoram

    2013-01-01

    We propose a real-time cardiac imaging method with parallel MRI that allows for free breathing during imaging and does not require cardiac or respiratory gating. The method is based on the recently proposed PARADISE (Patient-Adaptive Reconstruction and Acquisition Dynamic Imaging with Sensitivity Encoding) scheme. The new acquisition method adapts the PARADISE k-t space sampling pattern according to an affine model of the respiratory motion. The reconstruction scheme involves multi-channel time-sequential imaging with time-varying channels. All model parameters are adapted to the imaged patient as part of the experiment and drive both data acquisition and cine reconstruction. Simulated cardiac MRI experiments using the realistic NCAT phantom show high quality cine reconstructions and robustness to modeling inaccuracies. PMID:24390159

  17. Segmentation and tracking in echocardiographic sequences: active contours guided by optical flow estimates

    NASA Technical Reports Server (NTRS)

    Mikic, I.; Krucinski, S.; Thomas, J. D.

    1998-01-01

    This paper presents a method for segmentation and tracking of cardiac structures in ultrasound image sequences. The developed algorithm is based on the active contour framework. This approach requires initial placement of the contour close to the desired position in the image, usually an object outline. Best contour shape and position are then calculated, assuming that at this configuration a global energy function, associated with a contour, attains its minimum. Active contours can be used for tracking by selecting a solution from a previous frame as an initial position in a present frame. Such an approach, however, fails for large displacements of the object of interest. This paper presents a technique that incorporates the information on pixel velocities (optical flow) into the estimate of initial contour to enable tracking of fast-moving objects. The algorithm was tested on several ultrasound image sequences, each covering one complete cardiac cycle. The contour successfully tracked boundaries of mitral valve leaflets, aortic root and endocardial borders of the left ventricle. The algorithm-generated outlines were compared against manual tracings by expert physicians. The automated method resulted in contours that were within the boundaries of intraobserver variability.

  18. Cardiac Sarcoidosis: Clinical Manifestations, Imaging Characteristics, and Therapeutic Approach

    PubMed Central

    Houston, Brian A; Mukherjee, Monica

    2014-01-01

    Sarcoidosis is a multi-system disease pathologically characterized by the accumulation of T-lymphocytes and mononuclear phagocytes into the sine qua non pathologic structure of the noncaseating granuloma. Cardiac involvement remains a key source of morbidity and mortality in sarcoidosis. Definitive diagnosis of cardiac sarcoidosis, particularly early enough in the disease course to provide maximal therapeutic impact, has proven a particularly difficult challenge. However, major advancements in imaging techniques have been made in the last decade. Advancements in imaging modalities including echocardiography, nuclear spectroscopy, positron emission tomography, and magnetic resonance imaging all have improved our ability to diagnose cardiac sarcoidosis, and in many cases to provide a more accurate prognosis and thus targeted therapy. Likewise, therapy for cardiac sarcoidosis is beginning to advance past a “steroids-only” approach, as novel immunosuppressant agents provide effective steroid-sparing options. The following focused review will provide a brief discussion of the epidemiology and clinical presentation of cardiac sarcoidosis followed by a discussion of up-to-date imaging modalities employed in its assessment and therapeutic approaches. PMID:25452702

  19. Role of imaging in evaluation of sudden cardiac death risk in hypertrophic cardiomyopathy.

    PubMed

    Geske, Jeffrey B; Ommen, Steve R

    2015-09-01

    Hypertrophic cardiomyopathy (HCM) is the most common heritable cardiomyopathy and is associated with sudden cardiac death (SCD) - an uncommon but devastating clinical outcome. This review is designed to assess the role of imaging in established risk factor assessment and its role in emerging SCD risk stratification. Recent publications have highlighted the crucial role of imaging in HCM SCD risk stratification. Left ventricular hypertrophy assessment remains the key imaging determinant of risk. Data continue to emerge on the role of systolic dysfunction, apical aneurysms, left atrial enlargement and left ventricular outflow tract obstruction as markers of risk. Quantitative assessment of delayed myocardial enhancement and T1 mapping on cardiac MRI continue to evolve. Recent multicenter trials have allowed multivariate SCD risk assessment in large HCM cohorts. Given aggregate risk with presence of multiple risk factors, a single parameter should not be used in isolation to determine implantable cardiac defibrillator candidacy. Use of all available imaging data, including cardiac magnetic resonance tissue characterization, allows a comprehensive approach to SCD stratification and implantable cardiac defibrillator decision-making.

  20. Cardiac radiology: centenary review.

    PubMed

    de Roos, Albert; Higgins, Charles B

    2014-11-01

    During the past century, cardiac imaging technologies have revolutionized the diagnosis and treatment of acquired and congenital heart disease. Many important contributions to the field of cardiac imaging were initially reported in Radiology. The field developed from the early stages of cardiac imaging, including the use of coronary x-ray angiography and roentgen kymography, to nowadays the widely used echocardiographic, nuclear medicine, cardiac computed tomographic (CT), and magnetic resonance (MR) applications. It is surprising how many of these techniques were not recognized for their potential during their early inception. Some techniques were described in the literature but required many years to enter the clinical arena and presently continue to expand in terms of clinical application. The application of various CT and MR contrast agents for the diagnosis of myocardial ischemia is a case in point, as the utility of contrast agents continues to expand the noninvasive characterization of myocardium. The history of cardiac imaging has included a continuous process of advances in our understanding of the anatomy and physiology of the cardiovascular system, along with advances in imaging technology that continue to the present day.

  1. SU-E-P-10: Imaging in the Cardiac Catheterization Lab - Technologies and Clinical Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fetterly, K

    2014-06-01

    Purpose: Diagnosis and treatment of cardiovascular disease in the cardiac catheterization laboratory is often aided by a multitude of imaging technologies. The purpose of this work is to highlight the contributions to patient care offered by the various imaging systems used during cardiovascular interventional procedures. Methods: Imaging technologies used in the cardiac catheterization lab were characterized by their fundamental technology and by the clinical applications for which they are used. Whether the modality is external to the patient, intravascular, or intracavity was specified. Specific clinical procedures for which multiple modalities are routinely used will be highlighted. Results: X-ray imaging modalitiesmore » include fluoroscopy/angiography and angiography CT. Ultrasound imaging is performed with external, trans-esophageal echocardiography (TEE), and intravascular (IVUS) transducers. Intravascular infrared optical coherence tomography (IVOCT) is used to assess vessel endothelium. Relatively large (>0.5 mm) anatomical structures are imaged with x-ray and ultrasound. IVUS and IVOCT provide high resolution images of vessel walls. Cardiac CT and MRI images are used to plan complex cardiovascular interventions. Advanced applications are used to spatially and temporally merge images from different technologies. Diagnosis and treatment of coronary artery disease frequently utilizes angiography and intra-vascular imaging, and treatment of complex structural heart conditions routinely includes use of multiple imaging modalities. Conclusion: There are several imaging modalities which are routinely used in the cardiac catheterization laboratory to diagnose and treat both coronary artery and structural heart disease. Multiple modalities are frequently used to enhance the quality and safety of procedures. The cardiac catheterization laboratory includes many opportunities for medical physicists to contribute substantially toward advancing patient care.« less

  2. Empiric versus imaging guided left ventricular lead placement in cardiac resynchronization therapy (ImagingCRT): study protocol for a randomized controlled trial.

    PubMed

    Sommer, Anders; Kronborg, Mads Brix; Poulsen, Steen Hvitfeldt; Böttcher, Morten; Nørgaard, Bjarne Linde; Bouchelouche, Kirsten; Mortensen, Peter Thomas; Gerdes, Christian; Nielsen, Jens Cosedis

    2013-04-26

    Cardiac resynchronization therapy (CRT) is an established treatment in heart failure patients. However, a large proportion of patients remain nonresponsive to this pacing strategy. Left ventricular (LV) lead position is one of the main determinants of response to CRT. This study aims to clarify whether multimodality imaging guided LV lead placement improves clinical outcome after CRT. The ImagingCRT study is a prospective, randomized, patient- and assessor-blinded, two-armed trial. The study is designed to investigate the effect of imaging guided left ventricular lead positioning on a clinical composite primary endpoint comprising all-cause mortality, hospitalization for heart failure, or unchanged or worsened functional capacity (no improvement in New York Heart Association class and <10% improvement in six-minute-walk test). Imaging guided LV lead positioning is targeted to the latest activated non-scarred myocardial region by speckle tracking echocardiography, single-photon emission computed tomography, and cardiac computed tomography. Secondary endpoints include changes in LV dimensions, ejection fraction and dyssynchrony. A total of 192 patients are included in the study. Despite tremendous advances in knowledge with CRT, the proportion of patients not responding to this treatment has remained stable since the introduction of CRT. ImagingCRT is a prospective, randomized study assessing the clinical and echocardiographic effect of multimodality imaging guided LV lead placement in CRT. The results are expected to make an important contribution in the pursuit of increasing response rate to CRT. Clinicaltrials.gov identifier NCT01323686. The trial was registered March 25, 2011 and the first study subject was randomized April 11, 2011.

  3. TU-G-BRA-08: BEST IN PHYSICS (JOINT IMAGING-THERAPY): Hybrid PET-MRI Imaging of Acute Radiation Induced Cardiac Toxicity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    El-Sherif, O; Xhaferllari, I; Gaede, S

    Purpose: To identify the presence of low-dose radiation induced cardiac toxicity in a canine model using hybrid positron emission tomography (PET) and magnetic resonance imaging (MRI). Methods: Research ethics board approval was obtained for a longitudinal imaging study of 5 canines after cardiac irradiation. Animals were imaged at baseline, 1 week post cardiac irradiation, and 1 month post cardiac irradiation using a hybrid PET- MRI system (Biograph mMR, Siemens Healthcare). The imaging protocol was designed to assess acute changes in myocardial perfusion and inflammation. Myocardial perfusion imaging was performed using N13-ammonia tracer followed by a dynamic PET acquisition scan. Amore » compartmental tracer kinetic model was used for absolute perfusion quantification. Myocardial inflammation imaging was performed using F18-fluorodeoxyglucose (FDG) tracer. The standard uptake value (SUV) over a region encompassing the whole heart was used to compare FDG scans. All animals received a simulation CT scan (GE Medical Systems) for radiation treatment planning. Radiation treatment plans were created using the Pinncale3 treatment planning system (Philips Radiation Oncology Systems) and designed to resemble the typical cardiac exposure during left-sided breast cancer radiotherapy. Cardiac irradiations were performed in a single fraction using a TrueBeam linear accelerator (Varian Medical Systems). Results: The delivered dose (mean ± standard deviation) to heart was 1.8±0.2 Gy. Reductions in myocardial stress perfusion relative to baseline were observed in 2 of the 5 animals 1 month post radiation. A global inflammatory response 1 month post radiation was observed in 4 of the 5 animals. The calculated SUV at 1 month post radiation was significantly higher (p=0.05) than the baseline SUV. Conclusion: Low doses of cardiac irradiation (< 2 Gy) may lead to myocardial perfusion defects and a global inflammatory response that can be detectable as early as 1 month post irradiation using hybrid PET-MRI imaging techniques.« less

  4. Low-dose 4D cardiac imaging in small animals using dual source micro-CT

    NASA Astrophysics Data System (ADS)

    Holbrook, M.; Clark, D. P.; Badea, C. T.

    2018-01-01

    Micro-CT is widely used in preclinical studies, generating substantial interest in extending its capabilities in functional imaging applications such as blood perfusion and cardiac function. However, imaging cardiac structure and function in mice is challenging due to their small size and rapid heart rate. To overcome these challenges, we propose and compare improvements on two strategies for cardiac gating in dual-source, preclinical micro-CT: fast prospective gating (PG) and uncorrelated retrospective gating (RG). These sampling strategies combined with a sophisticated iterative image reconstruction algorithm provide faster acquisitions and high image quality in low-dose 4D (i.e. 3D  +  Time) cardiac micro-CT. Fast PG is performed under continuous subject rotation which results in interleaved projection angles between cardiac phases. Thus, fast PG provides a well-sampled temporal average image for use as a prior in iterative reconstruction. Uncorrelated RG incorporates random delays during sampling to prevent correlations between heart rate and sampling rate. We have performed both simulations and animal studies to validate these new sampling protocols. Sampling times for 1000 projections using fast PG and RG were 2 and 3 min, respectively, and the total dose was 170 mGy each. Reconstructions were performed using a 4D iterative reconstruction technique based on the split Bregman method. To examine undersampling robustness, subsets of 500 and 250 projections were also used for reconstruction. Both sampling strategies in conjunction with our iterative reconstruction method are capable of resolving cardiac phases and provide high image quality. In general, for equal numbers of projections, fast PG shows fewer errors than RG and is more robust to undersampling. Our results indicate that only 1000-projection based reconstruction with fast PG satisfies a 5% error criterion in left ventricular volume estimation. These methods promise low-dose imaging with a wide range of preclinical applications in cardiac imaging.

  5. Aldosterone Target NGAL (Neutrophil Gelatinase-Associated Lipocalin) Is Involved in Cardiac Remodeling After Myocardial Infarction Through NFκB Pathway.

    PubMed

    Martínez-Martínez, Ernesto; Buonafine, Mathieu; Boukhalfa, Ines; Ibarrola, Jaime; Fernández-Celis, Amaya; Kolkhof, Peter; Rossignol, Patrick; Girerd, Nicolas; Mulder, Paul; López-Andrés, Natalia; Ouvrard-Pascaud, Antoine; Jaisser, Frédéric

    2017-12-01

    Myocardial infarction (MI) is accompanied by cardiac fibrosis, which contributes to cardiac dysfunction. Mineralocorticoid receptor (MR) antagonists have beneficial effects in patients with left ventricular (LV) dysfunction after MI. We herein investigated the role of the MR target NGAL (neutrophil gelatinase-associated lipocalin) in post-MI cardiac damages. Both higher baseline NGAL and a greater increase in serum NGAL levels during follow-up were significantly associated with lower 6-month LV ejection fraction recovery in a cohort of 119 post-MI patients, as assessed by cardiac magnetic resonance imaging. NGAL protein levels increased in the LV at 7 days post-MI in wild-type mice with MI. This effect was prevented by treatment with the nonsteroidal MR antagonist finerenone (1 mg/kg per day). NGAL knockout mice with MI had lower LV interstitial fibrosis and inflammation, better LV contractility and compliance, and greater stroke volume and cardiac output than wild-type mice with MI at 3 months post-MI. Aldosterone (10 -8 mol/L) increased NGAL expression in cultured human cardiac fibroblasts. Cells treated with aldosterone or NGAL (500 ng/mL) showed increased production of collagen type I. The effects of aldosterone were abolished by finerenone (10 -6 mol/L) or NGAL knockdown. This NGAL-mediated activity relied on NFκB (nuclear factor-κB) activation, confirmed by the use of the NFκB-specific inhibitor BAY11-7082, which prevented the effect of both aldosterone and NGAL on collagen type I production. In conclusion, NGAL, a downstream MR activation target, is a key mediator of post-MI cardiac damage. NGAL may be a potential therapeutic target in cardiovascular pathological situations in which MR is involved. © 2017 American Heart Association, Inc.

  6. Automatic Delineation of the Myocardial Wall from CT Images via Shape Segmentation and Variational Region Growing

    PubMed Central

    Zhu, Liangjia; Gao, Yi; Appia, Vikram; Yezzi, Anthony; Arepalli, Chesnal; Faber, Tracy; Stillman, Arthur; Tannenbaum, Allen

    2014-01-01

    Prognosis and diagnosis of cardiac diseases frequently require quantitative evaluation of the ventricle volume, mass, and ejection fraction. The delineation of the myocardial wall is involved in all of these evaluations, which is a challenging task due to large variations in myocardial shapes and image quality. In this work, we present an automatic method for extracting the myocardial wall of the left and right ventricles from cardiac CT images. In the method, the left and right ventricles are located sequentially, in which each ventricle is detected by first identifying the endocardium and then segmenting the epicardium. To this end, the endocardium is localized by utilizing its geometric features obtained on-line from a CT image. After that, a variational region-growing model is employed to extract the epicardium of the ventricles. In particular, the location of the endocardium of the left ventricle is determined via using an active contour model on the blood-pool surface. To localize the right ventricle, the active contour model is applied on a heart surface extracted based on the left ventricle segmentation result. The robustness and accuracy of the proposed approach is demonstrated by experimental results from 33 human and 12 pig CT images. PMID:23744658

  7. Myocardial Iron Loading Assessment by Automatic Left Ventricle Segmentation with Morphological Operations and Geodesic Active Contour on T2* images

    NASA Astrophysics Data System (ADS)

    Luo, Yun-Gang; Ko, Jacky Kl; Shi, Lin; Guan, Yuefeng; Li, Linong; Qin, Jing; Heng, Pheng-Ann; Chu, Winnie Cw; Wang, Defeng

    2015-07-01

    Myocardial iron loading thalassemia patients could be identified using T2* magnetic resonance images (MRI). To quantitatively assess cardiac iron loading, we proposed an effective algorithm to segment aligned free induction decay sequential myocardium images based on morphological operations and geodesic active contour (GAC). Nine patients with thalassemia major were recruited (10 male and 16 female) to undergo a thoracic MRI scan in the short axis view. Free induction decay images were registered for T2* mapping. The GAC were utilized to segment aligned MR images with a robust initialization. Segmented myocardium regions were divided into sectors for a region-based quantification of cardiac iron loading. Our proposed automatic segmentation approach achieve a true positive rate at 84.6% and false positive rate at 53.8%. The area difference between manual and automatic segmentation was 25.5% after 1000 iterations. Results from T2* analysis indicated that regions with intensity lower than 20 ms were suffered from heavy iron loading in thalassemia major patients. The proposed method benefited from abundant edge information of the free induction decay sequential MRI. Experiment results demonstrated that the proposed method is feasible in myocardium segmentation and was clinically applicable to measure myocardium iron loading.

  8. Endocardial left ventricle feature tracking and reconstruction from tri-plane trans-esophageal echocardiography data

    NASA Astrophysics Data System (ADS)

    Dangi, Shusil; Ben-Zikri, Yehuda K.; Cahill, Nathan; Schwarz, Karl Q.; Linte, Cristian A.

    2015-03-01

    Two-dimensional (2D) ultrasound (US) has been the clinical standard for over two decades for monitoring and assessing cardiac function and providing support via intra-operative visualization and guidance for minimally invasive cardiac interventions. Developments in three-dimensional (3D) image acquisition and transducer design and technology have revolutionized echocardiography imaging enabling both real-time 3D trans-esophageal and intra-cardiac image acquisition. However, in most cases the clinicians do not access the entire 3D image volume when analyzing the data, rather they focus on several key views that render the cardiac anatomy of interest during the US imaging exam. This approach enables image acquisition at a much higher spatial and temporal resolution. Two such common approaches are the bi-plane and tri-plane data acquisition protocols; as their name states, the former comprises two orthogonal image views, while the latter depicts the cardiac anatomy based on three co-axially intersecting views spaced at 600 to one another. Since cardiac anatomy is continuously changing, the intra-operative anatomy depicted using real-time US imaging also needs to be updated by tracking the key features of interest and endocardial left ventricle (LV) boundaries. Therefore, rapid automatic feature tracking in US images is critical for three reasons: 1) to perform cardiac function assessment; 2) to identify location of surgical targets for accurate tool to target navigation and on-target instrument positioning; and 3) to enable pre- to intra-op image registration as a means to fuse pre-op CT or MR images used during planning with intra-operative images for enhanced guidance. In this paper we utilize monogenic filtering, graph-cut based segmentation and robust spline smoothing in a combined work flow to process the acquired tri-plane TEE time series US images and demonstrate robust and accurate tracking of the LV endocardial features. We reconstruct the endocardial LV geometry using the tri-plane contours and spline interpolation, and assess the accuracy of the proposed work flow against gold-standard results from the GE Echopac PC clinical software according to quantitative clinical LV characterization parameters, such as the length, circumference, area and volume. Our proposed combined work flow leads to consistent, rapid and automated identification of the LV endocardium, suitable for intra-operative applications and "on-the-fly" computer-assisted assessment of ejection fraction for cardiac function monitoring.Two-dimensional (2D) ultrasound (US) has been the clinical standard for over two decades for monitoring and assessing cardiac function and providing support via intra-operative visualization and guidance for minimally invasive cardiac interventions. Developments in three-dimensional (3D) image acquisition and transducer design and technology have revolutionized echocardiography imaging enabling both real-time 3D trans-esophageal and intra-cardiac image acquisition. However, in most cases the clinicians do not access the entire 3D image volume when analyzing the data, rather they focus on several key views that render the cardiac anatomy of interest during the US imaging exam. This approach enables image acquisition at a much higher spatial and temporal resolution. Two such common approaches are the bi-plane and tri-plane data acquisition protocols; as their name states, the former comprises two orthogonal image views, while the latter depicts the cardiac anatomy based on three co-axially intersecting views spaced at 600 to one another. Since cardiac anatomy is continuously changing, the intra-operative anatomy depicted using real-time US imaging also needs to be updated by tracking the key features of interest and endocardial left ventricle (LV) boundaries. Therefore, rapid automatic feature tracking in US images is critical for three reasons: 1) to perform cardiac function assessment; 2) to identify location of surgical targets for accurate tool to target navigation and on-target instrument positioning; and 3) to enable pre- to intra-op image registration as a means to fuse pre-op CT or MR images used during planning with intra-operative images for enhanced guidance. In this paper we utilize monogenic filtering, graph-cut based segmentation and robust spline smoothing in a combined work flow to process the acquired tri-plane TEE time series US images and demonstrate robust and accurate tracking of the LV endocardial features. We reconstruct the endocardial LV geometry using the tri-plane contours and spline interpolation, and assess the accuracy of the proposed work flow against gold-standard results from the GE Echopac PC clinical software according to quantitative clinical LV characterization parameters, such as the length, circumference, area and volume. Our proposed combined work flow leads to consistent, rapid and automated identification of the LV endocardium, suitable for intra-operative applications and on-the- y" computer-assisted assessment of ejection fraction for cardiac function monitoring.

  9. In vivo Post-Cardiac Arrest Myocardial Dysfunction is Supported by CaMKII-Mediated Calcium Long-Term Potentiation and Mitigated by Alda-1, an Agonist of Aldehyde Dehydrogenase Type 2

    PubMed Central

    Downey, Peter; Zalewski, Adrian; Rubio, Gabriel R.; Liu, Jing; Homburger, Julian R.; Grunwald, Zachary; Qi, Wei; Bollensdorff, Christian; Thanaporn, Porama; Ali, Ayyaz; Riemer, Kirk; Kohl, Peter; Mochly-Rosen, Daria; Gerstenfeld, Edward; Large, Stephen; Ali, Ziad; Ashley, Euan

    2016-01-01

    Background Survival after sudden cardiac arrest is limited by post-arrest myocardial dysfunction but understanding of this phenomenon is constrained by lack of data from a physiological model of disease. In this study, we established an in vivo model of cardiac arrest and resuscitation, characterized the biology of the associated myocardial dysfunction, and tested novel therapeutic strategies. Methods We developed rodent models of in vivo post-arrest myocardial dysfunction using extra-corporeal membrane oxygenation (ECMO) resuscitation followed by invasive hemodynamics measurement. In post-arrest isolated cardiomyocytes, we assessed mechanical load and Ca2+ induced Ca2+ release (CICR) simultaneously using the micro-carbon-fiber technique and observed reduced function and myofilament calcium sensitivity. We used a novel-designed fiber optic catheter imaging system, and a genetically encoded calcium sensor GCaMP6f, to image CICR in vivo. Results We found potentiation of CICR in isolated cells from this ECMO model and also in cells isolated from an ischemia-reperfusion Langendorff model perfused with oxygenated blood from an arrested animal, but not when reperfused in saline. We established that CICR potentiation begins in vivo. The augmented CICR observed post-arrest was mediated by the activation of Ca2+/calmodulin kinase II (CaMKII). Increased phosphorylation of CaMKII, phospholamban and ryanodine receptor 2 (RyR2) was detected in the post-arrest period. Exogenous adrenergic activation in vivo recapitulated Ca2+ potentiation but was associated with lesser CaMKII activation. Since oxidative stress and aldehydic adduct formation were high post arrest, we tested a small molecule activator of aldehyde dehydrogenase type 2, Alda-1, which reduced oxidative stress, restored calcium and CaMKII homeostasis, and improved cardiac function and post-arrest outcome in vivo. Conclusions Cardiac arrest and reperfusion lead to CaMKII activation and calcium long-term potentiation which support cardiomyocyte contractility in the face of impaired post-ischemic myofilament calcium sensitivity. Alda-1 mitigates these effects, normalizes calcium cycling and improves outcome. PMID:27582424

  10. Nuclear cardiology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Penkava, R.R.

    1985-05-01

    Radionuclide cardiac imaging is a safe, noninvasive alternative to cardiac catheterization for observation and evaluation of cardiac wall motion and calculation of ejection fraction. Nuclide imaging offers a greater degree of sensitivity and specificity in detecting myocardial ischemia and infarction than do conventional electrocardiographic and cardiac enzyme studies. It is especially useful in problem cases. Myocardial infarction can usually be evaluated with respect to size and relative age of infarction.

  11. Cardiovascular applications of magnetic resonance imaging

    PubMed Central

    Pflugfelder, Peter W.; Wisenberg, Gerald; Prato, Frank S.

    1985-01-01

    Magnetic resonance (MR) imaging is a unique imaging modality that is gaining rapid acceptance for a variety of medical indications. Diagnostic information is obtained noninvasively, without the potential hazards of ionizing radiation. The spatial resolution and anatomic detail of MR imaging rival those of other currently available imaging methods. By gating to an electrocardiographic signal cardiac imaging is possible. Since March 1983 the authors have had experience with cardiac MR imaging in both animals and humans. Cardiac anatomy is well shown by this technique, which allows detection and characterization of intracardiac masses, congenital heart disease and anomalies of the great vessels. Myocardial infarction has been detected in both animals and humans without the use of contrast agents, and acute cardiac transplant rejection has been visualized in an animal model. Limitations of MR imaging primarily have been lengthy imaging times and the sensitivity of the images to motion. With further investigation and experience this technique may become useful for studying a wide variety of cardiovascular disorders. ImagesFig. 2Fig. 3Fig. 4Fig. 5Fig. 6 PMID:3904969

  12. Targeted transgenic overexpression of mitochondrial thymidine kinase (TK2) alters mitochondrial DNA (mtDNA) and mitochondrial polypeptide abundance: transgenic TK2, mtDNA, and antiretrovirals.

    PubMed

    Hosseini, Seyed H; Kohler, James J; Haase, Chad P; Tioleco, Nina; Stuart, Tami; Keebaugh, Erin; Ludaway, Tomika; Russ, Rodney; Green, Elgin; Long, Robert; Wang, Liya; Eriksson, Staffan; Lewis, William

    2007-03-01

    Mitochondrial toxicity limits nucleoside reverse transcriptase inhibitors (NRTIs) for acquired immune deficiency syndrome. NRTI triphosphates, the active moieties, inhibit human immunodeficiency virus reverse transcriptase and eukaryotic mitochondrial DNA polymerase pol-gamma. NRTI phosphorylation seems to correlate with mitochondrial toxicity, but experimental evidence is lacking. Transgenic mice (TGs) with cardiac overexpression of thymidine kinase isoforms (mitochondrial TK2 and cytoplasmic TK1) were used to study NRTI mitochondrial toxicity. Echocardiography and nuclear magnetic resonance imaging defined cardiac performance and structure. TK gene copy and enzyme activity, mitochondrial (mt) DNA and polypeptide abundance, succinate dehydrogenase and cytochrome oxidase histochemistry, and electron microscopy correlated with transgenesis, mitochondrial structure, and biogenesis. Antiretroviral combinations simulated therapy. Untreated hTK1 or TK2 TGs exhibited normal left ventricle mass. In TK2 TGs, cardiac TK2 gene copy doubled, activity increased 300-fold, and mtDNA abundance doubled. Abundance of the 17-kd subunit of complex I, succinate dehydrogenase histochemical activity, and cristae density increased. NRTIs increased left ventricle mass 20% in TK2 TGs. TK activity increased 3 logs in hTK1 TGs, but no cardiac phenotype resulted. NRTIs abrogated functional effects of transgenically increased TK2 activity but had no effect on TK2 mtDNA abundance. Thus, NRTI mitochondrial phosphorylation by TK2 is integral to clinical NRTI mitochondrial toxicity.

  13. Targeted Transgenic Overexpression of Mitochondrial Thymidine Kinase (TK2) Alters Mitochondrial DNA (mtDNA) and Mitochondrial Polypeptide Abundance

    PubMed Central

    Hosseini, Seyed H.; Kohler, James J.; Haase, Chad P.; Tioleco, Nina; Stuart, Tami; Keebaugh, Erin; Ludaway, Tomika; Russ, Rodney; Green, Elgin; Long, Robert; Wang, Liya; Eriksson, Staffan; Lewis, William

    2007-01-01

    Mitochondrial toxicity limits nucleoside reverse transcriptase inhibitors (NRTIs) for acquired immune deficiency syndrome. NRTI triphosphates, the active moieties, inhibit human immunodeficiency virus reverse transcriptase and eukaryotic mitochondrial DNA polymerase pol-γ. NRTI phosphorylation seems to correlate with mitochondrial toxicity, but experimental evidence is lacking. Transgenic mice (TGs) with cardiac overexpression of thymidine kinase isoforms (mitochondrial TK2 and cytoplasmic TK1) were used to study NRTI mitochondrial toxicity. Echocardiography and nuclear magnetic resonance imaging defined cardiac performance and structure. TK gene copy and enzyme activity, mitochondrial (mt) DNA and polypeptide abundance, succinate dehydrogenase and cytochrome oxidase histochemistry, and electron microscopy correlated with transgenesis, mitochondrial structure, and biogenesis. Antiretroviral combinations simulated therapy. Untreated hTK1 or TK2 TGs exhibited normal left ventricle mass. In TK2 TGs, cardiac TK2 gene copy doubled, activity increased 300-fold, and mtDNA abundance doubled. Abundance of the 17-kd subunit of complex I, succinate dehydrogenase histochemical activity, and cristae density increased. NRTIs increased left ventricle mass 20% in TK2 TGs. TK activity increased 3 logs in hTK1 TGs, but no cardiac phenotype resulted. NRTIs abrogated functional effects of transgenically increased TK2 activity but had no effect on TK2 mtDNA abundance. Thus, NRTI mitochondrial phosphorylation by TK2 is integral to clinical NRTI mitochondrial toxicity. PMID:17322372

  14. Registration of fast cine cardiac MR slices to 3D preprocedural images: toward real-time registration for MRI-guided procedures

    NASA Astrophysics Data System (ADS)

    Smolikova, Renata; Wachowiak, Mark P.; Drangova, Maria

    2004-05-01

    Interventional cardiac magnetic resonance (MR) procedures are the subject of an increasing number of research studies. Typically, during the procedure only two-dimensional images of oblique slices can be presented to the interventionalist in real time. There is a clear benefit to being able to register the real-time 2D slices to a previously acquired 3D computed tomography (CT) or MR image of the heart. Results from a study of the accuracy of registration of 2D cardiac images of an anesthetized pig to a 3D volume obtained in diastole are presented. Fast cine MR images representing twenty phases of the cardiac cycle were obtained of a 2D slice in a known oblique orientation. The 2D images were initially mis-oriented at distances ranging from 2 to 20 mm, and rotations of +/-10 degrees about all three axes. Images from all 20 cardiac phases were registered to examine the effect of timing between the 2D image and the 3D pre-procedural image. Linear registration using mutual information computed with 64 histogram bins yielded the highest accuracy. For the diastolic phases, mean translation and rotation errors ranged between 0.91 and 1.32 mm and between 1.73 and 2.10 degrees. Scans acquired at other phases also had high accuracy. These results are promising for the use of real time MR in image-guided cardiac interventions, and demonstrate the feasibility of registering 2D oblique MR slices to previously acquired single-phase volumes without preprocessing.

  15. Automatic initialization and quality control of large-scale cardiac MRI segmentations.

    PubMed

    Albà, Xènia; Lekadir, Karim; Pereañez, Marco; Medrano-Gracia, Pau; Young, Alistair A; Frangi, Alejandro F

    2018-01-01

    Continuous advances in imaging technologies enable ever more comprehensive phenotyping of human anatomy and physiology. Concomitant reduction of imaging costs has resulted in widespread use of imaging in large clinical trials and population imaging studies. Magnetic Resonance Imaging (MRI), in particular, offers one-stop-shop multidimensional biomarkers of cardiovascular physiology and pathology. A wide range of analysis methods offer sophisticated cardiac image assessment and quantification for clinical and research studies. However, most methods have only been evaluated on relatively small databases often not accessible for open and fair benchmarking. Consequently, published performance indices are not directly comparable across studies and their translation and scalability to large clinical trials or population imaging cohorts is uncertain. Most existing techniques still rely on considerable manual intervention for the initialization and quality control of the segmentation process, becoming prohibitive when dealing with thousands of images. The contributions of this paper are three-fold. First, we propose a fully automatic method for initializing cardiac MRI segmentation, by using image features and random forests regression to predict an initial position of the heart and key anatomical landmarks in an MRI volume. In processing a full imaging database, the technique predicts the optimal corrective displacements and positions in relation to the initial rough intersections of the long and short axis images. Second, we introduce for the first time a quality control measure capable of identifying incorrect cardiac segmentations with no visual assessment. The method uses statistical, pattern and fractal descriptors in a random forest classifier to detect failures to be corrected or removed from subsequent statistical analysis. Finally, we validate these new techniques within a full pipeline for cardiac segmentation applicable to large-scale cardiac MRI databases. The results obtained based on over 1200 cases from the Cardiac Atlas Project show the promise of fully automatic initialization and quality control for population studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. A 3D Hermite-based multiscale local active contour method with elliptical shape constraints for segmentation of cardiac MR and CT volumes.

    PubMed

    Barba-J, Leiner; Escalante-Ramírez, Boris; Vallejo Venegas, Enrique; Arámbula Cosío, Fernando

    2018-05-01

    Analysis of cardiac images is a fundamental task to diagnose heart problems. Left ventricle (LV) is one of the most important heart structures used for cardiac evaluation. In this work, we propose a novel 3D hierarchical multiscale segmentation method based on a local active contour (AC) model and the Hermite transform (HT) for LV analysis in cardiac magnetic resonance (MR) and computed tomography (CT) volumes in short axis view. Features such as directional edges, texture, and intensities are analyzed using the multiscale HT space. A local AC model is configured using the HT coefficients and geometrical constraints. The endocardial and epicardial boundaries are used for evaluation. Segmentation of the endocardium is controlled using elliptical shape constraints. The final endocardial shape is used to define the geometrical constraints for segmentation of the epicardium. We follow the assumption that epicardial and endocardial shapes are similar in volumes with short axis view. An initialization scheme based on a fuzzy C-means algorithm and mathematical morphology was designed. The algorithm performance was evaluated using cardiac MR and CT volumes in short axis view demonstrating the feasibility of the proposed method.

  17. White matter changes in comatose survivors of anoxic ischemic encephalopathy and traumatic brain injury: comparative diffusion-tensor imaging study.

    PubMed

    van der Eerden, Anke W; Khalilzadeh, Omid; Perlbarg, Vincent; Dinkel, Julien; Sanchez, Paola; Vos, Pieter E; Luyt, Charles-Edouard; Stevens, Robert D; Menjot de Champfleur, Nicolas; Delmaire, Christine; Tollard, Eleonore; Gupta, Rajiv; Dormont, Didier; Laureys, Steven; Benali, Habib; Vanhaudenhuyse, Audrey; Galanaud, Damien; Puybasset, Louis

    2014-02-01

    To analyze white matter pathologic abnormalities by using diffusion-tensor (DT) imaging in a multicenter prospective cohort of comatose patients following cardiac arrest or traumatic brain injury (TBI). Institutional review board approval and informed consent from proxies and control subjects were obtained. DT imaging was performed 5-57 days after insult in 49 cardiac arrest and 40 TBI patients. To control for DT imaging-processing variability, patients' values were normalized to those of 111 control subjects. Automated segmentation software calculated normalized axial diffusivity (λ1) and radial diffusivity (λ⊥) in 19 predefined white matter regions of interest (ROIs). DT imaging variables were compared by using general linear modeling, and side-to-side Pearson correlation coefficients were calculated. P values were corrected for multiple testing (Bonferroni). In central white matter, λ1 differed from that in control subjects in six of seven TBI ROIs and five of seven cardiac arrest ROIs (all P < .01). The λ⊥ differed from that in control subjects in all ROIs in both patient groups (P < .01). In hemispheres, λ1 was decreased compared with that in control subjects in three of 12 TBI ROIs (P < .05) and nine of 12 cardiac arrest ROIs (P < .01). The λ⊥ was increased in all TBI ROIs (P < .01) and in seven of 12 cardiac arrest ROIs (P < .05). Cerebral hemisphere λ1 was lower in cardiac arrest than in TBI in six of 12 ROIs (P < .01), while λ⊥ was higher in TBI than in cardiac arrest in eight of 12 ROIs (P < .01). Diffusivity values were symmetrically distributed in cardiac arrest (P < .001 for side-to-side correlation) but not in TBI patients. DT imaging findings are consistent with the known predominance of cerebral hemisphere axonal injury in cardiac arrest and chiefly central myelin injury in TBI. This consistency supports the validity of DT imaging for differentiating axon and myelin damage in vivo in humans. © RSNA, 2013

  18. Biomechanics of Early Cardiac Development

    PubMed Central

    Goenezen, Sevan; Rennie, Monique Y.

    2012-01-01

    Biomechanics affect early cardiac development, from looping to the development of chambers and valves. Hemodynamic forces are essential for proper cardiac development, and their disruption leads to congenital heart defects. A wealth of information already exists on early cardiac adaptations to hemodynamic loading, and new technologies, including high resolution imaging modalities and computational modeling, are enabling a more thorough understanding of relationships between hemodynamics and cardiac development. Imaging and modeling approaches, used in combination with biological data on cell behavior and adaptation, are paving the road for new discoveries on links between biomechanics and biology and their effect on cardiac development and fetal programming. PMID:22760547

  19. Ultrasound Imaging in Teaching Cardiac Physiology

    ERIC Educational Resources Information Center

    Johnson, Christopher D.; Montgomery, Laura E. A.; Quinn, Joe G.; Roe, Sean M.; Stewart, Michael T.; Tansey, Etain A.

    2016-01-01

    This laboratory session provides hands-on experience for students to visualize the beating human heart with ultrasound imaging. Simple views are obtained from which students can directly measure important cardiac dimensions in systole and diastole. This allows students to derive, from first principles, important measures of cardiac function, such…

  20. Stress Perfusion Cardiac Magnetic Resonance Imaging Effectively Risk Stratifies Diabetic Patients With Suspected Myocardial Ischemia.

    PubMed

    Heydari, Bobak; Juan, Yu-Hsiang; Liu, Hui; Abbasi, Siddique; Shah, Ravi; Blankstein, Ron; Steigner, Michael; Jerosch-Herold, Michael; Kwong, Raymond Y

    2016-04-01

    Diabetics remain at high risk of cardiovascular disease and mortality despite advancements in medical therapy. Noninvasive cardiac risk profiling is often more difficult in diabetics owing to the prevalence of silent ischemia with unrecognized myocardial infarction, reduced exercise capacity, nondiagnostic electrocardiographic changes, and balanced ischemia from diffuse epicardial coronary atherosclerosis and microvascular dysfunction. A consecutive cohort of 173 patients with diabetes mellitus (mean age, 61.7±11.9 years; 37% women) with suspected myocardial ischemia underwent stress perfusion cardiac magnetic resonance imaging. Patients were evaluated for adverse cardiac events after cardiac magnetic resonance imaging with mean follow-up time of 2.9±2.5 years. Mean hemoglobin A1c for the population was 7.9±1.8%. Primary end point was a composite of cardiac death and nonfatal myocardial infarction. Diabetics with no inducible ischemia (n=94) experienced an annualized event rate of 1.4% compared with 8.2% (P=0.0003) in those with inducible ischemia (n=79). Diabetics without late gadolinium enhancement or inducible ischemia had a low annual cardiac event rate (0.5% per year). The presence of inducible ischemia was the strongest unadjusted predictor (hazard ratio, 4.86; P<0.01) for cardiac death and nonfatal myocardial infarction. This association remained robust in adjusted stepwise multivariable Cox regression analysis (hazard ratio, 4.28; P=0.02). In addition, categorical net reclassification index using 5-year risk cutoffs of 5% and 10% resulted in reclassification of 43.4% of the diabetic cohort with net reclassification index of 0.38 (95% confidence interval, 0.20-0.56; P<0.0001). Stress perfusion cardiac magnetic resonance imaging provided independent prognostic utility and effectively reclassified risk in patients with diabetes mellitus referred for ischemic assessment. Further evaluation is required to determine whether a noninvasive imaging strategy with cardiac magnetic resonance imaging can favorably affect downstream outcomes and improve cost-effectiveness of care in diabetics. © 2016 American Heart Association, Inc.

  1. Clinical use of cardiac PET/MRI: current state-of-the-art and potential future applications.

    PubMed

    Krumm, Patrick; Mangold, Stefanie; Gatidis, Sergios; Nikolaou, Konstantin; Nensa, Felix; Bamberg, Fabian; la Fougère, Christian

    2018-05-01

    Combined PET/MRI is a novel imaging method integrating the advances of functional and morphological MR imaging with PET applications that include assessment of myocardial viability, perfusion, metabolism of inflammatory tissue and tumors, as well as amyloid deposition imaging. As such, PET/MRI is a promising tool to detect and characterize ischemic and non-ischemic cardiomyopathies. To date, the greatest benefit may be expected for diagnostic evaluation of systemic diseases and cardiac masses that remain unclear in cardiac MRI, as well as for clinical and scientific studies in the setting of ischemic cardiomyopathies. Diagnosis and therapeutic monitoring of cardiac sarcoidosis has the potential of a possible 'killer-application' for combined cardiac PET/MRI. In this article, we review the current evidence and discuss current and potential future applications of cardiac PET/MRI.

  2. Free-breathing imaging of the heart using 2D cine-GRICS (generalized reconstruction by inversion of coupled systems) with assessment of ventricular volumes and function.

    PubMed

    Vuissoz, Pierre-André; Odille, Freddy; Fernandez, Brice; Lohezic, Maelene; Benhadid, Adnane; Mandry, Damien; Felblinger, Jacques

    2012-02-01

    To assess cardiac function by means of a novel free-breathing cardiac magnetic resonance imaging (MRI) strategy. A stack of ungated 2D steady-state free precession (SSFP) slices was acquired during free breathing and reconstructed as cardiac cine imaging based on the generalized reconstruction by inversion of coupled systems (GRICS). A motion-compensated sliding window approach allows reconstructing cine movies with most motion artifacts cancelled. The proposed reconstruction uses prior knowledge from respiratory belts and electrocardiogram recordings and features a piecewise linear model that relates the electrocardiogram signal to cardiac displacements. The free-breathing protocol was validated in six subjects against a standard breath-held protocol. Image sharpness, as assessed by the image gradient entropy, was comparable to that of breath-held images and significantly better than in uncorrected images. Volumetric parameters of cardiac function in the left ventricle (LV) and right ventricle (RV) were similar, including end-systolic volumes, end-diastolic volumes and mass, stroke volumes, and ejection fractions (with differences of 3% ± 2.4 in the LV and 2.9% ± 4.4 in the RV). The duration of the free-breathing protocol was nearly the same as the breath-held protocol. Free-breathing cine-GRICS enables accurate assessment of volumetric parameters of cardiac function with efficient correction of motion. Copyright © 2011 Wiley Periodicals, Inc.

  3. Murine fetal echocardiography.

    PubMed

    Kim, Gene H

    2013-02-15

    Transgenic mice displaying abnormalities in cardiac development and function represent a powerful tool for the understanding the molecular mechanisms underlying both normal cardiovascular function and the pathophysiological basis of human cardiovascular disease. Fetal and perinatal death is a common feature when studying genetic alterations affecting cardiac development. In order to study the role of genetic or pharmacologic alterations in the early development of cardiac function, ultrasound imaging of the live fetus has become an important tool for early recognition of abnormalities and longitudinal follow-up. Noninvasive ultrasound imaging is an ideal method for detecting and studying congenital malformations and the impact on cardiac function prior to death. It allows early recognition of abnormalities in the living fetus and the progression of disease can be followed in utero with longitudinal studies. Until recently, imaging of fetal mouse hearts frequently involved invasive methods. The fetus had to be sacrificed to perform magnetic resonance microscopy and electron microscopy or surgically delivered for transillumination microscopy. An application of high-frequency probes with conventional 2-D and pulsed-wave Doppler imaging has been shown to provide measurements of cardiac contraction and heart rates during embryonic development with databases of normal developmental changes now available. M-mode imaging further provides important functional data, although, the proper imaging planes are often difficult to obtain. High-frequency ultrasound imaging of the fetus has improved 2-D resolution and can provide excellent information on the early development of cardiac structures.

  4. Compressed sensing reconstruction of cardiac cine MRI using golden angle spiral trajectories

    NASA Astrophysics Data System (ADS)

    Tolouee, Azar; Alirezaie, Javad; Babyn, Paul

    2015-11-01

    In dynamic cardiac cine Magnetic Resonance Imaging (MRI), the spatiotemporal resolution is limited by the low imaging speed. Compressed sensing (CS) theory has been applied to improve the imaging speed and thus the spatiotemporal resolution. The purpose of this paper is to improve CS reconstruction of under sampled data by exploiting spatiotemporal sparsity and efficient spiral trajectories. We extend k-t sparse algorithm to spiral trajectories to achieve high spatio temporal resolutions in cardiac cine imaging. We have exploited spatiotemporal sparsity of cardiac cine MRI by applying a 2D + time wavelet-Fourier transform. For efficient coverage of k-space, we have used a modified version of multi shot (interleaved) spirals trajectories. In order to reduce incoherent aliasing artifact, we use different random undersampling pattern for each temporal frame. Finally, we have used nonuniform fast Fourier transform (NUFFT) algorithm to reconstruct the image from the non-uniformly acquired samples. The proposed approach was tested in simulated and cardiac cine MRI data. Results show that higher acceleration factors with improved image quality can be obtained with the proposed approach in comparison to the existing state-of-the-art method. The flexibility of the introduced method should allow it to be used not only for the challenging case of cardiac imaging, but also for other patient motion where the patient moves or breathes during acquisition.

  5. Effects of radiation exposure from cardiac imaging: how good are the data?

    PubMed

    Einstein, Andrew J

    2012-02-07

    Concerns about medical exposure to ionizing radiation have become heightened in recent years as a result of rapid growth in procedure volumes and the high radiation doses incurred from some procedures. This paper summarizes the evidence base undergirding concerns about radiation exposure in cardiac imaging. After classifying radiation effects, explaining terminology used to quantify the radiation received by patients, and describing typical doses from cardiac imaging procedures, this paper will address the major epidemiological studies having bearing on radiation effects at doses comparable to those received by patients undergoing cardiac imaging. These include studies of atomic bomb survivors, nuclear industry workers, and children exposed in utero to x-rays, all of which have evidenced increased cancer risks at low doses. Additional higher-dose epidemiological studies of cohorts exposed to radiation in the context of medical treatment are described and found to be generally compatible with these cardiac dose-level studies, albeit with exceptions. Using risk projection models developed by the U.S. National Academies that incorporate these data and reflect several evidence-based assumptions, cancer risk from cardiac imaging can be estimated and compared with the benefits from imaging. Several ongoing epidemiological studies will provide better understanding of radiation-associated cancer risks. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. Accelerometer-Based Method for Extracting Respiratory and Cardiac Gating Information for Dual Gating during Nuclear Medicine Imaging

    PubMed Central

    Pänkäälä, Mikko; Paasio, Ari

    2014-01-01

    Both respiratory and cardiac motions reduce the quality and consistency of medical imaging specifically in nuclear medicine imaging. Motion artifacts can be eliminated by gating the image acquisition based on the respiratory phase and cardiac contractions throughout the medical imaging procedure. Electrocardiography (ECG), 3-axis accelerometer, and respiration belt data were processed and analyzed from ten healthy volunteers. Seismocardiography (SCG) is a noninvasive accelerometer-based method that measures accelerations caused by respiration and myocardial movements. This study was conducted to investigate the feasibility of the accelerometer-based method in dual gating technique. The SCG provides accelerometer-derived respiratory (ADR) data and accurate information about quiescent phases within the cardiac cycle. The correct information about the status of ventricles and atria helps us to create an improved estimate for quiescent phases within a cardiac cycle. The correlation of ADR signals with the reference respiration belt was investigated using Pearson correlation. High linear correlation was observed between accelerometer-based measurement and reference measurement methods (ECG and Respiration belt). Above all, due to the simplicity of the proposed method, the technique has high potential to be applied in dual gating in clinical cardiac positron emission tomography (PET) to obtain motion-free images in the future. PMID:25120563

  7. Register cardiac fiber orientations from 3D DTI volume to 2D ultrasound image of rat hearts

    NASA Astrophysics Data System (ADS)

    Qin, Xulei; Wang, Silun; Shen, Ming; Zhang, Xiaodong; Lerakis, Stamatios; Wagner, Mary B.; Fei, Baowei

    2015-03-01

    Two-dimensional (2D) ultrasound or echocardiography is one of the most widely used examinations for the diagnosis of cardiac diseases. However, it only supplies the geometric and structural information of the myocardium. In order to supply more detailed microstructure information of the myocardium, this paper proposes a registration method to map cardiac fiber orientations from three-dimensional (3D) magnetic resonance diffusion tensor imaging (MR-DTI) volume to the 2D ultrasound image. It utilizes a 2D/3D intensity based registration procedure including rigid, log-demons, and affine transformations to search the best similar slice from the template volume. After registration, the cardiac fiber orientations are mapped to the 2D ultrasound image via fiber relocations and reorientations. This method was validated by six images of rat hearts ex vivo. The evaluation results indicated that the final Dice similarity coefficient (DSC) achieved more than 90% after geometric registrations; and the inclination angle errors (IAE) between the mapped fiber orientations and the gold standards were less than 15 degree. This method may provide a practical tool for cardiologists to examine cardiac fiber orientations on ultrasound images and have the potential to supply additional information for diagnosis of cardiac diseases.

  8. Comparison of treadmill exercise stress cardiac MRI to stress echocardiography in healthy volunteers for adequacy of left ventricular endocardial wall visualization: A pilot study

    PubMed Central

    Thavendiranathan, Paaladinesh; Dickerson, Jennifer A.; Scandling, Debbie; Balasubramanian, Vijay; Pennell, Michael L.; Hinton, Alice; Raman, Subha V.; Simonetti, Orlando P.

    2013-01-01

    Purpose To compare exercise stress cardiac magnetic resonance (cardiac MR) to echocardiography in healthy volunteers with respect to adequacy of endocardial visualization and confidence of stress study interpretation. Materials and Methods 28 healthy volunteers (aged 28 ± 11 years, 15 males) underwent exercise stress echo and cardiac MR one week apart assigned randomly to one test first. Stress cardiac MR was performed using an MRI-compatible treadmill; stress echo was performed as per routine protocol. Cardiac MR and echo images were independently reviewed and scored for adequacy of endocardial visualization and confidence in interpretation of the stress study. Results Heart rate at the time of imaging was similar between the studies. Average time from cessation of exercise to start of imaging (21 vs. 31 seconds, p<0.001) and time to acquire stress images (20 vs. 51 seconds, p<0.001) was shorter for cardiac MR. The number of myocardial segments adequately visualized was significantly higher by cardiac MR at rest (99.8% versus 96.4%, p=0.002) and stress (99.8% versus 94.1%, p=0.001). The proportion of subjects in whom there was high confidence in the interpretation was higher for cardiac MR than echo (96% vs 60%, p=0.005). Conclusion Exercise stress cardiac MR to assess peak exercise wall motion is feasible and can be performed at least as rapidly as stress echo. PMID:24123562

  9. Benefits and limitations of multimodality imaging in the diagnosis of a primary cardiac lymphoma.

    PubMed

    Nijjar, Prabhjot Singh; Masri, Sofia Carolina; Tamene, Ashenafi; Kassahun, Helina; Liao, Kenneth; Valeti, Uma

    2014-12-01

    Primary cardiac tumors are far rarer than tumors metastatic to the heart. Angiosarcoma is the primary cardiac neoplasm most frequently detected; lymphomas constitute only 1% of primary cardiac tumors. We present the case of a 55-year-old woman with a recently diagnosed intracardiac mass who was referred to our institution for consideration of urgent orthotopic heart transplantation. Initial images suggested an angiosarcoma; however, a biopsy specimen of the mass was diagnostic for diffuse large B-cell lymphoma. The patient underwent chemotherapy rather than surgery, and she was asymptomatic 34 months later. We use our patient's case to discuss the benefits and limitations of multiple imaging methods in the evaluation of cardiac masses. Certain features revealed by computed tomography, cardiac magnetic resonance, and positron emission tomography can suggest a diagnosis of angiosarcoma rather than lymphoma. Cardiac magnetic resonance and positron emission tomography enable reliable distinction between benign and malignant tumors; however, the characteristics of different malignant tumors can overlap. Despite the great usefulness of multiple imaging methods for timely diagnosis, defining the extent of spread and the hemodynamic impact, and monitoring responses to treatment, we think that biopsy analysis is still warranted in order to obtain a correct histologic diagnosis in cases of suspected malignant cardiac tumors.

  10. Influence of cardiac and respiratory motion on tomographic reconstructions of the heart: implications for quantitative nuclear cardiology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ter-Pogossian, M.M.; Bergmann, S.R.; Sobel, B.E.

    1982-12-01

    The potential influence of physiological, periodic motions of the heart due to the cardiac cycle, the respiratory cycle, or both on quantitative image reconstruction by positron emission tomography (PET) has been largely neglected. To define their quantitative impact, cardiac PET was performed in 6 dogs after injection of /sup 11/C-palmitate under disparate conditions including: normal cardiac and respiration cycles and cardiac arrest with and without respiration. Although in vitro assay of myocardial samples demonstrated that palmitate uptake was homogeneous (coefficient of variation . 10.1%), analysis of the reconstructed images demonstrated significant heterogeneity of apparent cardiac distribution of radioactivity due tomore » both intrinsic cardiac and respiratory motion. Image degradation due to respiratory motion was demonstrated in a healthy human volunteer as well, in whom cardiac tomography was performed with Super PETT I during breath-holding and during normal breathing. The results indicate that quantitatively significant degradation of reconstructions of true tracer distribution occurs in cardiac PET due to both intrinsic cardiac and respiratory induced motion of the heart. They suggest that avoidance of or minimization of these influences can be accomplished by gating with respect to both the cardiac cycle and respiration or by employing brief scan times during breath-holding.« less

  11. Insights from Novel Noninvasive CT and ECG Imaging Modalities on Electromechanical Myocardial Activation in a Canine Model of Ischemic Dyssynchronous Heart Failure.

    PubMed

    Dawoud, Fady; Schuleri, Karl H; Spragg, David D; Horáček, B Milan; Berger, Ronald D; Halperin, Henry R; Lardo, Albert C

    2016-12-01

    The interplay between electrical activation and mechanical contraction patterns is hypothesized to be central to reduced effectiveness of cardiac resynchronization therapy (CRT). Furthermore, complex scar substrates render CRT less effective. We used novel cardiac computed tomography (CT) and noninvasive electrocardiographic imaging (ECGI) techniques in an ischemic dyssynchronous heart failure (DHF) animal model to evaluate electrical and mechanical coupling of cardiac function, tissue viability, and venous accessibility of target pacing regions. Ischemic DHF was induced in 6 dogs using coronary occlusion, left bundle ablation and tachy RV pacing. Full body ECG was recorded during native rhythm followed by volumetric first-pass and delayed enhancement CT. Regional electrical activation were computed and overlaid with segmented venous anatomy and scar regions. Reconstructed electrical activation maps show consistency with LBBB starting on the RV and spreading in a "U-shaped" pattern to the LV. Previously reported lines of slow conduction are seen parallel to anterior or inferior interventricular grooves. Mechanical contraction showed large septal to lateral wall delay (80 ± 38 milliseconds vs. 123 ± 31 milliseconds, P = 0.0001). All animals showed electromechanical correlation except dog 5 with largest scar burden. Electromechanical decoupling was largest in basal lateral LV segments. We demonstrated a promising application of CT in combination with ECGI to gain insight into electromechanical function in ischemic dyssynchronous heart failure that can provide useful information to study regional substrate of CRT candidates. © 2016 Wiley Periodicals, Inc.

  12. Intelligent platforms for disease assessment: novel approaches in functional echocardiography.

    PubMed

    Sengupta, Partho P

    2013-11-01

    Accelerating trends in the dynamic digital era (from 2004 onward) has resulted in the emergence of novel parametric imaging tools that allow easy and accurate extraction of quantitative information from cardiac images. This review principally attempts to heighten the awareness of newer emerging paradigms that may advance acquisition, visualization and interpretation of the large functional data sets obtained during cardiac ultrasound imaging. Incorporation of innovative cognitive software that allow advanced pattern recognition and disease forecasting will likely transform the human-machine interface and interpretation process to achieve a more efficient and effective work environment. Novel technologies for automation and big data analytics that are already active in other fields need to be rapidly adapted to the health care environment with new academic-industry collaborations to enrich and accelerate the delivery of newer decision making tools for enhancing patient care. Copyright © 2013. Published by Elsevier Inc.

  13. In vivo quantification of amyloid burden in TTR-related cardiac amyloidosis

    PubMed Central

    Kollikowski, Alexander Marco; Kahles, Florian; Kintsler, Svetlana; Hamada, Sandra; Reith, Sebastian; Knüchel, Ruth; Röcken, Christoph; Mottaghy, Felix Manuel; Marx, Nikolaus; Burgmaier, Mathias

    2017-01-01

    Summary Cardiac transthyretin-related (ATTR) amyloidosis is a severe cardiomyopathy for which therapeutic approaches are currently under development. Because non-invasive imaging techniques such as cardiac magnetic resonance imaging and echocardiography are non-specific, the diagnosis of ATTR amyloidosis is still based on myocardial biopsy. Thus, diagnosis of ATTR amyloidosis is difficult in patients refusing myocardial biopsy. Furthermore, myocardial biopsy does not allow 3D-mapping and quantification of myocardial ATTR amyloid. In this report we describe a 99mTc-DPD-based molecular imaging technique for non-invasive single-step diagnosis, three-dimensional mapping and semiquantification of cardiac ATTR amyloidosis in a patient with suspected amyloid heart disease who initially rejected myocardial biopsy. This report underlines the clinical value of SPECT-based nuclear medicine imaging to enable non-invasive diagnosis of cardiac ATTR amyloidosis, particularly in patients rejecting biopsy. PMID:29259858

  14. The benefits of the Atlas of Human Cardiac Anatomy website for the design of cardiac devices.

    PubMed

    Spencer, Julianne H; Quill, Jason L; Bateman, Michael G; Eggen, Michael D; Howard, Stephen A; Goff, Ryan P; Howard, Brian T; Quallich, Stephen G; Iaizzo, Paul A

    2013-11-01

    This paper describes how the Atlas of Human Cardiac Anatomy website can be used to improve cardiac device design throughout the process of development. The Atlas is a free-access website featuring novel images of both functional and fixed human cardiac anatomy from over 250 human heart specimens. This website provides numerous educational tutorials on anatomy, physiology and various imaging modalities. For instance, the 'device tutorial' provides examples of devices that were either present at the time of in vitro reanimation or were subsequently delivered, including leads, catheters, valves, annuloplasty rings and stents. Another section of the website displays 3D models of the vasculature, blood volumes and/or tissue volumes reconstructed from computed tomography and magnetic resonance images of various heart specimens. The website shares library images, video clips and computed tomography and MRI DICOM files in honor of the generous gifts received from donors and their families.

  15. An overview on development and application of an experimental platform for quantitative cardiac imaging research in rabbit models of myocardial infarction

    PubMed Central

    Feng, Yuanbo; Bogaert, Jan; Oyen, Raymond

    2014-01-01

    To exploit the advantages of using rabbits for cardiac imaging research and to tackle the technical obstacles, efforts have been made under the framework of a doctoral research program. In this overview article, by cross-referencing the current literature, we summarize how we have developed a preclinical cardiac research platform based on modified models of reperfused myocardial infarction (MI) in rabbits; how the in vivo manifestations of cardiac imaging could be closely matched with those ex vivo macro- and microscopic findings; how these imaging outcomes could be quantitatively analyzed, validated and demonstrated; and how we could apply this cardiac imaging platform to provide possible solutions to certain lingering diagnostic and therapeutic problems in experimental cardiology. In particular, tissue components in acute cardiac ischemia have been stratified and characterized, post-infarct lipomatous metaplasia (LM) as a common but hardly illuminated clinical pathology has been identified in rabbit models, and a necrosis avid tracer as well as an anti-ischemic drug have been successfully assessed for their potential utilities in clinical cardiology. These outcomes may interest the researchers in the related fields and help strengthen translational research in cardiovascular diseases. PMID:25392822

  16. An overview on development and application of an experimental platform for quantitative cardiac imaging research in rabbit models of myocardial infarction.

    PubMed

    Feng, Yuanbo; Bogaert, Jan; Oyen, Raymond; Ni, Yicheng

    2014-10-01

    To exploit the advantages of using rabbits for cardiac imaging research and to tackle the technical obstacles, efforts have been made under the framework of a doctoral research program. In this overview article, by cross-referencing the current literature, we summarize how we have developed a preclinical cardiac research platform based on modified models of reperfused myocardial infarction (MI) in rabbits; how the in vivo manifestations of cardiac imaging could be closely matched with those ex vivo macro- and microscopic findings; how these imaging outcomes could be quantitatively analyzed, validated and demonstrated; and how we could apply this cardiac imaging platform to provide possible solutions to certain lingering diagnostic and therapeutic problems in experimental cardiology. In particular, tissue components in acute cardiac ischemia have been stratified and characterized, post-infarct lipomatous metaplasia (LM) as a common but hardly illuminated clinical pathology has been identified in rabbit models, and a necrosis avid tracer as well as an anti-ischemic drug have been successfully assessed for their potential utilities in clinical cardiology. These outcomes may interest the researchers in the related fields and help strengthen translational research in cardiovascular diseases.

  17. An Efficient Framework for Compressed Sensing Reconstruction of Highly Accelerated Dynamic Cardiac MRI

    NASA Astrophysics Data System (ADS)

    Ting, Samuel T.

    The research presented in this work seeks to develop, validate, and deploy practical techniques for improving diagnosis of cardiovascular disease. In the philosophy of biomedical engineering, we seek to identify an existing medical problem having significant societal and economic effects and address this problem using engineering approaches. Cardiovascular disease is the leading cause of mortality in the United States, accounting for more deaths than any other major cause of death in every year since 1900 with the exception of the year 1918. Cardiovascular disease is estimated to account for almost one-third of all deaths in the United States, with more than 2150 deaths each day, or roughly 1 death every 40 seconds. In the past several decades, a growing array of imaging modalities have proven useful in aiding the diagnosis and evaluation of cardiovascular disease, including computed tomography, single photon emission computed tomography, and echocardiography. In particular, cardiac magnetic resonance imaging is an excellent diagnostic tool that can provide within a single exam a high quality evaluation of cardiac function, blood flow, perfusion, viability, and edema without the use of ionizing radiation. The scope of this work focuses on the application of engineering techniques for improving imaging using cardiac magnetic resonance with the goal of improving the utility of this powerful imaging modality. Dynamic cine imaging, or the capturing of movies of a single slice or volume within the heart or great vessel region, is used in nearly every cardiac magnetic resonance imaging exam, and adequate evaluation of cardiac function and morphology for diagnosis and evaluation of cardiovascular disease depends heavily on both the spatial and temporal resolution as well as the image quality of the reconstruction cine images. This work focuses primarily on image reconstruction techniques utilized in cine imaging; however, the techniques discussed are also relevant to other dynamic and static imaging techniques based on cardiac magnetic resonance. Conventional segmented techniques for cardiac cine imaging require breath-holding as well as regular cardiac rhythm, and can be time-consuming to acquire. Inadequate breath-holding or irregular cardiac rhythm can result in completely non-diagnostic images, limiting the utility of these techniques in a significant patient population. Real-time single-shot cardiac cine imaging enables free-breathing acquisition with significantly shortened imaging time and promises to significantly improve the utility of cine imaging for diagnosis and evaluation of cardiovascular disease. However, utility of real-time cine images depends heavily on the successful reconstruction of final cine images from undersampled data. Successful reconstruction of images from more highly undersampled data results directly in images exhibiting finer spatial and temporal resolution provided that image quality is sufficient. This work focuses primarily on the development, validation, and deployment of practical techniques for enabling the reconstruction of real-time cardiac cine images at the spatial and temporal resolutions and image quality needed for diagnostic utility. Particular emphasis is placed on the development of reconstruction approaches resulting in with short computation times that can be used in the clinical environment. Specifically, the use of compressed sensing signal recovery techniques is considered; such techniques show great promise in allowing successful reconstruction of highly undersampled data. The scope of this work concerns two primary topics related to signal recovery using compressed sensing: (1) long reconstruction times of these techniques, and (2) improved sparsity models for signal recovery from more highly undersampled data. Both of these aspects are relevant to the practical application of compressed sensing techniques in the context of improving image reconstruction of real-time cardiac cine images. First, algorithmic and implementational approaches are proposed for reducing the computational time for a compressed sensing reconstruction framework. Specific optimization algorithms based on the fast iterative/shrinkage algorithm (FISTA) are applied in the context of real-time cine image reconstruction to achieve efficient per-iteration computation time. Implementation within a code framework utilizing commercially available graphics processing units (GPUs) allows for practical and efficient implementation directly within the clinical environment. Second, patch-based sparsity models are proposed to enable compressed sensing signal recovery from highly undersampled data. Numerical studies demonstrate that this approach can help improve image quality at higher undersampling ratios, enabling real-time cine imaging at higher acceleration rates. In this work, it is shown that these techniques yield a holistic framework for achieving efficient reconstruction of real-time cine images with spatial and temporal resolution sufficient for use in the clinical environment. A thorough description of these techniques from both a theoretical and practical view is provided - both of which may be of interest to the reader in terms of future work.

  18. Cardiac structure and function in the obese: a cardiovascular magnetic resonance imaging study.

    PubMed

    Danias, Peter G; Tritos, Nicholas A; Stuber, Matthias; Kissinger, Kraig V; Salton, Carol J; Manning, Warren J

    2003-07-01

    Obesity is a major health problem in the Western world. Among obese subjects cardiac pathology is common, but conventional noninvasive imaging modalities are often suboptimal for detailed evaluation of cardiac structure and function. We investigated whether cardiovascular magnetic resonance imaging (CMR) can better characterize possible cardiac abnormalities associated with obesity, in the absence of other confounding comorbidities. In this prospective cross-sectional study, CMR was used to quantify left and right ventricular volumes, ejection fraction, mass, cardiac output, and apical left ventricular rotation in 25 clinically healthy obese men and 25 age-matched lean controls. Obese subjects had higher left ventricular mass (203 +/- 38 g vs. 163 +/- 22 g, p < 0.001), end-diastolic volume (176 +/- 29 mL vs. 156 +/- 25 mL, p < 0.05), and cardiac output (8.2 +/- 1.2 L/min vs. 6.4 +/- 1.3 L/min, p < 0.001). The obese also had increased right ventricular mass (105 +/- 25 g vs. 87 +/- 18 g, p < 0.005) and end-diastolic volume (179 +/- 36 mL vs. 155 +/- 28 mL, p < 0.05). When indexed for height, differences in left and right ventricular mass, and left ventricular end-diastolic volume remained significant. Apical left ventricular rotation and rotational velocity patterns were also different between obese and lean subjects. Obesity is independently associated with remodeling of the heart. Cardiovascular magnetic resonance imaging identifies subtle cardiac abnormalities and may be the preferred imaging technique to evaluate cardiac structure and function in the obese.

  19. Cardiac imaging with multi-sector data acquisition in volumetric CT: variation of effective temporal resolution and its potential clinical consequences

    NASA Astrophysics Data System (ADS)

    Tang, Xiangyang; Hsieh, Jiang; Taha, Basel H.; Vass, Melissa L.; Seamans, John L.; Okerlund, Darin R.

    2009-02-01

    With increasing longitudinal detector dimension available in diagnostic volumetric CT, step-and-shoot scan is becoming popular for cardiac imaging. In comparison to helical scan, step-and-shoot scan decouples patient table movement from cardiac gating/triggering, which facilitates the cardiac imaging via multi-sector data acquisition, as well as the administration of inter-cycle heart beat variation (arrhythmia) and radiation dose efficiency. Ideally, a multi-sector data acquisition can improve temporal resolution at a factor the same as the number of sectors (best scenario). In reality, however, the effective temporal resolution is jointly determined by gantry rotation speed and patient heart beat rate, which may significantly lower than the ideal or no improvement (worst scenario). Hence, it is clinically relevant to investigate the behavior of effective temporal resolution in cardiac imaging with multi-sector data acquisition. In this study, a 5-second cine scan of a porcine heart, which cascades 6 porcine cardiac cycles, is acquired. In addition to theoretical analysis and motion phantom study, the clinical consequences due to the effective temporal resolution variation are evaluated qualitative or quantitatively. By employing a 2-sector image reconstruction strategy, a total of 15 (the permutation of P(6, 2)) cases between the best and worst scenarios are studied, providing informative guidance for the design and optimization of CT cardiac imaging in volumetric CT with multi-sector data acquisition.

  20. Multiphysics and multiscale modelling, data-model fusion and integration of organ physiology in the clinic: ventricular cardiac mechanics.

    PubMed

    Chabiniok, Radomir; Wang, Vicky Y; Hadjicharalambous, Myrianthi; Asner, Liya; Lee, Jack; Sermesant, Maxime; Kuhl, Ellen; Young, Alistair A; Moireau, Philippe; Nash, Martyn P; Chapelle, Dominique; Nordsletten, David A

    2016-04-06

    With heart and cardiovascular diseases continually challenging healthcare systems worldwide, translating basic research on cardiac (patho)physiology into clinical care is essential. Exacerbating this already extensive challenge is the complexity of the heart, relying on its hierarchical structure and function to maintain cardiovascular flow. Computational modelling has been proposed and actively pursued as a tool for accelerating research and translation. Allowing exploration of the relationships between physics, multiscale mechanisms and function, computational modelling provides a platform for improving our understanding of the heart. Further integration of experimental and clinical data through data assimilation and parameter estimation techniques is bringing computational models closer to use in routine clinical practice. This article reviews developments in computational cardiac modelling and how their integration with medical imaging data is providing new pathways for translational cardiac modelling.

  1. Real-time dynamic display of registered 4D cardiac MR and ultrasound images using a GPU

    NASA Astrophysics Data System (ADS)

    Zhang, Q.; Huang, X.; Eagleson, R.; Guiraudon, G.; Peters, T. M.

    2007-03-01

    In minimally invasive image-guided surgical interventions, different imaging modalities, such as magnetic resonance imaging (MRI), computed tomography (CT), and real-time three-dimensional (3D) ultrasound (US), can provide complementary, multi-spectral image information. Multimodality dynamic image registration is a well-established approach that permits real-time diagnostic information to be enhanced by placing lower-quality real-time images within a high quality anatomical context. For the guidance of cardiac procedures, it would be valuable to register dynamic MRI or CT with intraoperative US. However, in practice, either the high computational cost prohibits such real-time visualization of volumetric multimodal images in a real-world medical environment, or else the resulting image quality is not satisfactory for accurate guidance during the intervention. Modern graphics processing units (GPUs) provide the programmability, parallelism and increased computational precision to begin to address this problem. In this work, we first outline our research on dynamic 3D cardiac MR and US image acquisition, real-time dual-modality registration and US tracking. Then we describe image processing and optimization techniques for 4D (3D + time) cardiac image real-time rendering. We also present our multimodality 4D medical image visualization engine, which directly runs on a GPU in real-time by exploiting the advantages of the graphics hardware. In addition, techniques such as multiple transfer functions for different imaging modalities, dynamic texture binding, advanced texture sampling and multimodality image compositing are employed to facilitate the real-time display and manipulation of the registered dual-modality dynamic 3D MR and US cardiac datasets.

  2. How much image noise can be added in cardiac x-ray imaging without loss in perceived image quality?

    NASA Astrophysics Data System (ADS)

    Gislason-Lee, Amber J.; Kumcu, Asli; Kengyelics, Stephen M.; Rhodes, Laura A.; Davies, Andrew G.

    2015-03-01

    Dynamic X-ray imaging systems are used for interventional cardiac procedures to treat coronary heart disease. X-ray settings are controlled automatically by specially-designed X-ray dose control mechanisms whose role is to ensure an adequate level of image quality is maintained with an acceptable radiation dose to the patient. Current commonplace dose control designs quantify image quality by performing a simple technical measurement directly from the image. However, the utility of cardiac X-ray images is in their interpretation by a cardiologist during an interventional procedure, rather than in a technical measurement. With the long term goal of devising a clinically-relevant image quality metric for an intelligent dose control system, we aim to investigate the relationship of image noise with clinical professionals' perception of dynamic image sequences. Computer-generated noise was added, in incremental amounts, to angiograms of five different patients selected to represent the range of adult cardiac patient sizes. A two alternative forced choice staircase experiment was used to determine the amount of noise which can be added to a patient image sequences without changing image quality as perceived by clinical professionals. Twenty-five viewing sessions (five for each patient) were completed by thirteen observers. Results demonstrated scope to increase the noise of cardiac X-ray images by up to 21% +/- 8% before it is noticeable by clinical professionals. This indicates a potential for 21% radiation dose reduction since X-ray image noise and radiation dose are directly related; this would be beneficial to both patients and personnel.

  3. Safety of capsule endoscopy using human body communication in patients with cardiac devices.

    PubMed

    Chung, Joo Won; Hwang, Hye Jin; Chung, Moon Jae; Park, Jeong Youp; Pak, Hui-Nam; Song, Si Young

    2012-06-01

    The MiroCam (IntroMedic, Ltd., Seoul, Korea) is a small-bowel capsule endoscope that uses human body communication to transmit data. The potential interactions between cardiac devices and the capsule endoscope are causes for concern, but no data are available for this matter. This clinical study was designed to evaluate the potential influence of the MiroCam capsules on cardiac devices. Patients with cardiac pacemakers or implantable cardiac defibrillators referred for evaluation of small bowel disease were prospectively enrolled in this study. Before capsule endoscopy, a cardiologist checked baseline electrocardiograms and functions of the cardiac devices. Cardiac rhythms were continuously monitored by 24-h telemetry during capsule endoscopy in the hospital. After completion of procedures, functions of the cardiac devices were checked again for interference. Images from the capsule endoscopy were reviewed and analyzed for technical problems. Six patients, three with pacemakers and three with implantable cardiac defibrillators, were included in the study. We identified no disturbances in the cardiac devices and no arrhythmias detected on telemetry monitoring during capsule endoscopy. No significant changes in the programmed parameters of the cardiac devices were noted after capsule endoscopy. There were no imaging disturbances from the cardiac devices on capsule endoscopy. Capsule endoscopy using human body communication to transmit data was safely performed in patients with cardiac pacemakers or implantable cardiac defibrillators. Images from the capsule endoscopy were not affected by cardiac devices. A further large-scale study is required to confirm the safety of capsule endoscopy with various types of cardiac devices.

  4. Thermal Infrared Imaging-Based Computational Psychophysiology for Psychometrics.

    PubMed

    Cardone, Daniela; Pinti, Paola; Merla, Arcangelo

    2015-01-01

    Thermal infrared imaging has been proposed as a potential system for the computational assessment of human autonomic nervous activity and psychophysiological states in a contactless and noninvasive way. Through bioheat modeling of facial thermal imagery, several vital signs can be extracted, including localized blood perfusion, cardiac pulse, breath rate, and sudomotor response, since all these parameters impact the cutaneous temperature. The obtained physiological information could then be used to draw inferences about a variety of psychophysiological or affective states, as proved by the increasing number of psychophysiological studies using thermal infrared imaging. This paper presents therefore a review of the principal achievements of thermal infrared imaging in computational physiology with regard to its capability of monitoring psychophysiological activity.

  5. Instant images of the human heart using a new, whole-body MR imaging system.

    PubMed

    Rzedzian, R R; Pykett, I L

    1987-08-01

    An extremely rapid MR imaging technique is described, and its use on a new 2.0-T high-speed MR system is demonstrated. This implementation permits complete filling of the two-dimensional spatial-frequency domain (k-space) within an acquisition window of 26 msec. With this acquisition window placed under the spin-echo signal envelope generated by a 90-180 degree pulse pair, the image contrast is the same as that of a conventional spin-echo pulse sequence. Resultant proton images have a motion-independent voxel resolution of 0.08 cm3 and a signal-to-noise ratio for cardiac muscle of approximately 30:1 (for TE = 30 msec) with no signal averaging. The pulse sequence yields images that are chemical shift-resolved. The total proton density distribution is optionally presented with lipid and water signals displayed in two different colors. Cardiac function is observed by displaying multiple images, acquired at different times in successive cardiac periods, in a cyclic movie format. Such motion pictures are obtained within a single period of suspended respiration, thereby assuring freedom from respiratory related motion artifacts. As preliminary examples, we present MR images of the normal adult human heart that have total acquisition times of only 40 msec/image and that show the major cardiac anatomy. Frames from movie loops show contraction of cardiac chambers and left ventricular wall thickening. The extremely rapid acquisition time of this technique suggests that it may hold promise for the routine and cost-effective evaluation of cardiac anatomy and function.

  6. Evaluation of motion-correction methods for dual-gated cardiac positron emission tomography/computed tomography imaging.

    PubMed

    Klén, Riku; Noponen, Tommi; Koikkalainen, Juha; Lötjönen, Jyrki; Thielemans, Kris; Hoppela, Erika; Sipilä, Hannu; Teräs, Mika; Knuuti, Juhani

    2016-09-01

    Dual gating is a method of dividing the data of a cardiac PET scan into smaller bins according to the respiratory motion and the ECG of the patient. It reduces the undesirable motion artefacts in images, but produces several images for interpretation and decreases the quality of single images. By using motion-correction techniques, the motion artefacts in the dual-gated images can be corrected and the images can be combined into a single motion-free image with good statistics. The aim of the present study is to develop and evaluate motion-correction methods for cardiac PET studies. We have developed and compared two different methods: computed tomography (CT)/PET-based and CT-only methods. The methods were implemented and tested with a cardiac phantom and three patient datasets. In both methods, anatomical information of CT images is used to create models for the cardiac motion. In the patient study, the CT-only method reduced motion (measured as the centre of mass of the myocardium) on average 43%, increased the contrast-to-noise ratio on average 6.0% and reduced the target size on average 10%. Slightly better figures (51, 6.9 and 28%) were obtained with the CT/PET-based method. Even better results were obtained in the phantom study for both the CT-only method (57, 68 and 43%) and the CT/PET-based method (61, 74 and 52%). We conclude that using anatomical information of CT for motion correction of cardiac PET images, both respiratory and pulsatile motions can be corrected with good accuracy.

  7. Three- and four-dimensional reconstruction of intra-cardiac anatomy from two-dimensional magnetic resonance images.

    PubMed

    Miquel, M E; Hill, D L G; Baker, E J; Qureshi, S A; Simon, R D B; Keevil, S F; Razavi, R S

    2003-06-01

    The present study was designed to evaluate the feasibility and clinical usefulness of three-dimensional (3D) reconstruction of intra-cardiac anatomy from a series of two-dimensional (2D) MR images using commercially available software. Sixteen patients (eight with structurally normal hearts but due to have catheter radio-frequency ablation of atrial tachyarrhythmias and eight with atrial septal defects (ASD) due for trans-catheter closure) and two volunteers were imaged at 1T. For each patient, a series of ECG-triggered images (5 mm thick slices, 2-3 mm apart) were acquired during breath holding. Depending on image quality, T1- or T2-weighted spin-echo images or gradient-echo cine images were used. The 3D reconstruction was performed off-line: the blood pools within cardiac chambers and great vessels were semi-automatically segmented, their outer surface was extracted using a marching cube algorithm and rendered. Intra- and inter-observer variability, effect of breath-hold position and differences between pulse sequences were assessed by imaging a volunteer. The 3D reconstructions were assessed by three cardiologists and compared with the 2D MR images and with 2D and 3D trans-esophagal and intra-cardiac echocardiography obtained during interventions. In every case, an anatomically detailed 3D volume was obtained. In the two patients where a 3 mm interval between slices was used, the resolution was not as good but it was still possible to visualize all the major anatomical structures. Spin-echo images lead to reconstructions more detailed than those obtained from gradient-echo images. However, gradient-echo images are easier to segment due to their greater contrast. Furthermore, because images were acquired at least at ten points in the cardiac cycles for every slice it was possible to reconstruct a cine loop and, for example, to visualize the evolution of the size and margins of the ASD during the cardiac cycle. 3D reconstruction proved to be an effective way to assess the relationship between the different parts of the cardiac anatomy. The technique was useful in planning interventions in these patients.

  8. Functional cardiac magnetic resonance microscopy

    NASA Astrophysics Data System (ADS)

    Brau, Anja Christina Sophie

    2003-07-01

    The study of small animal models of human cardiovascular disease is critical to our understanding of the origin, progression, and treatment of this pervasive disease. Complete analysis of disease pathophysiology in these animal models requires measuring structural and functional changes at the level of the whole heart---a task for which an appropriate non-invasive imaging method is needed. The purpose of this work was thus to develop an imaging technique to support in vivo characterization of cardiac structure and function in rat and mouse models of cardiovascular disease. Whereas clinical cardiac magnetic resonance imaging (MRI) provides accurate assessment of the human heart, the extension of cardiac MRI from humans to rodents presents several formidable scaling challenges. Acquiring images of the mouse heart with organ definition and fluidity of contraction comparable to that achieved in humans requires an increase in spatial resolution by a factor of 3000 and an increase in temporal resolution by a factor of ten. No single technical innovation can meet the demanding imaging requirements imposed by the small animal. A functional cardiac magnetic resonance microscopy technique was developed by integrating improvements in physiological control, imaging hardware, biological synchronization of imaging, and pulse sequence design to achieve high-quality images of the murine heart with high spatial and temporal resolution. The specific methods and results from three different sets of imaging experiments are presented: (1) 2D functional imaging in the rat with spatial resolution of 175 mum2 x 1 mm and temporal resolution of 10 ms; (2) 3D functional imaging in the rat with spatial resolution of 100 mum 2 x 500 mum and temporal resolution of 30 ms; and (3) 2D functional imaging in the mouse with spatial resolution down to 100 mum2 x 1 mm and temporal resolution of 10 ms. The cardiac microscopy technique presented here represents a novel collection of technologies capable of acquiring routine high-quality images of murine cardiac structure and function with minimal artifacts and markedly higher spatial resolution compared to conventional techniques. This work is poised to serve a valuable role in the evaluation of cardiovascular disease and should find broad application in studies ranging from basic pathophysiology to drug discovery.

  9. Calculation of Cardiac Kinetic Energy Index from PET images.

    PubMed

    Sims, John; Oliveira, Marco Antônio; Meneghetti, José Claudio; Gutierrez, Marco Antônio

    2015-01-01

    Cardiac function can be assessed from displacement measurements in imaging modalities from nuclear medicine Using positron emission tomography (PET) image sequences with Rubidium-82, we propose and estimate the total Kinetic Energy Index (KEf) obtained from the velocity field, which was calculated using 3D optical flow(OF) methods applied over the temporal image sequence. However, it was found that the brightness of the image varied unexpectedly between frames, violating the constant brightness assumption of the OF method and causing large errors in estimating the velocity field. Therefore total brightness was equalized across image frames and the adjusted configuration tested with rest perfusion images acquired from individuals with normal (n=30) and low (n=33) cardiac function. For these images KEf was calculated as 0.5731±0.0899 and 0.3812±0.1146 for individuals with normal and low cardiac function respectively. The ability of KEf to properly classify patients into the two groups was tested with a ROC analysis, with area under the curve estimated as 0.906. To our knowledge this is the first time that KEf has been applied to PET images.

  10. New cardiac cameras: single-photon emission CT and PET.

    PubMed

    Slomka, Piotr J; Berman, Daniel S; Germano, Guido

    2014-07-01

    Nuclear cardiology instrumentation has evolved significantly in the recent years. Concerns about radiation dose and long acquisition times have propelled developments of dedicated high-efficiency cardiac SPECT scanners. Novel collimator designs, such as multipinhole or locally focusing collimators arranged in geometries that are optimized for cardiac imaging, have been implemented to enhance photon-detection sensitivity. Some of these new SPECT scanners use solid-state photon detectors instead of photomultipliers to improve image quality and to reduce the scanner footprint. These new SPECT devices allow dramatic up to 7-fold reduction in acquisition times or similar reduction in radiation dose. In addition, new hardware for photon attenuation correction allowing ultralow radiation doses has been offered by some vendors. To mitigate photon attenuation artifacts for the new SPECT scanners not equipped with attenuation correction hardware, 2-position (upright-supine or prone-supine) imaging has been proposed. PET hardware developments have been primarily driven by the requirements of oncologic imaging, but cardiac imaging can benefit from improved PET image quality and improved sensitivity of 3D systems. The time-of-flight reconstruction combined with resolution recovery techniques is now implemented by all major PET vendors. These new methods improve image contrast and image resolution and reduce image noise. High-sensitivity 3D PET without interplane septa allows reduced radiation dose for cardiac perfusion imaging. Simultaneous PET/MR hybrid system has been developed. Solid-state PET detectors with avalanche photodiodes or digital silicon photomultipliers have been introduced, and they offer improved imaging characteristics and reduced sensitivity to electromagnetic MR fields. Higher maximum count rate of the new PET detectors allows routine first-pass Rb-82 imaging, with 3D PET acquisition enabling clinical utilization of dynamic imaging with myocardial flow measurements for this tracer. The availability of high-end CT component in most PET/CT configurations enables hybrid multimodality cardiac imaging protocols with calcium scoring or CT angiography or both. Copyright © 2014. Published by Elsevier Inc.

  11. The role of advanced reconstruction algorithms in cardiac CT

    PubMed Central

    Halliburton, Sandra S.; Tanabe, Yuki; Partovi, Sasan

    2017-01-01

    Non-linear iterative reconstruction (IR) algorithms have been increasingly incorporated into clinical cardiac CT protocols at institutions around the world. Multiple IR algorithms are available commercially from various vendors. IR algorithms decrease image noise and are primarily used to enable lower radiation dose protocols. IR can also be used to improve image quality for imaging of obese patients, coronary atherosclerotic plaques, coronary stents, and myocardial perfusion. In this article, we will review the various applications of IR algorithms in cardiac imaging and evaluate how they have changed practice. PMID:29255694

  12. Cardiac sarcoidosis demonstrated by Tl-201 and Ga-67 SPECT imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taki, J.; Nakajima, K.; Bunko, H.

    1990-09-01

    Ga-67 and Tl-201 SPECT was performed to evaluate cardiac sarcoidosis in a 15-year-old boy. Tl-201 SPECT imaging showed decreased uptake in the inferior to lateral wall and Ga-67 accumulation in the area of decreased Tl-201 uptake. These findings suggested cardiac sarcoidosis, and cardiac biopsy confirmed this diagnosis. After corticosteroid therapy, myocardial uptake of Ga-67 disappeared and myocardial TI-201 uptake became more homogeneous.

  13. Myocardial strain estimation from CT: towards computer-aided diagnosis on infarction identification

    NASA Astrophysics Data System (ADS)

    Wong, Ken C. L.; Tee, Michael; Chen, Marcus; Bluemke, David A.; Summers, Ronald M.; Yao, Jianhua

    2015-03-01

    Regional myocardial strains have the potential for early quantification and detection of cardiac dysfunctions. Although image modalities such as tagged and strain-encoded MRI can provide motion information of the myocardium, they are uncommon in clinical routine. In contrary, cardiac CT images are usually available, but they only provide motion information at salient features such as the cardiac boundaries. To estimate myocardial strains from a CT image sequence, we adopted a cardiac biomechanical model with hyperelastic material properties to relate the motion on the cardiac boundaries to the myocardial deformation. The frame-to-frame displacements of the cardiac boundaries are obtained using B-spline deformable image registration based on mutual information, which are enforced as boundary conditions to the biomechanical model. The system equation is solved by the finite element method to provide the dense displacement field of the myocardium, and the regional values of the three principal strains and the six strains in cylindrical coordinates are computed in terms of the American Heart Association nomenclature. To study the potential of the estimated regional strains on identifying myocardial infarction, experiments were performed on cardiac CT image sequences of ten canines with artificially induced myocardial infarctions. The leave-one-subject-out cross validations show that, by using the optimal strain magnitude thresholds computed from ROC curves, the radial strain and the first principal strain have the best performance.

  14. Diagnostic cardiology: Noninvasive imaging techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Come, P.C.

    1985-01-01

    This book contains 23 chapters. Some of the chapter titles are: The chest x-ray and cardiac series; Computed tomographic scanning of the heart, coronary arteries, and great vessels; Digital subtraction angiography in the assessment of cardiovascular disease; Magnetic resonance: technique and cardiac applications; Basics of radiation physics and instrumentation; and Nuclear imaging: the assessment of cardiac performance.

  15. An experimental phantom study of the effect of gadolinium-based MR contrast agents on PET attenuation coefficients and PET quantification in PET-MR imaging: application to cardiac studies.

    PubMed

    O' Doherty, Jim; Schleyer, Paul

    2017-12-01

    Simultaneous cardiac perfusion studies are an increasing trend in PET-MR imaging. During dynamic PET imaging, the introduction of gadolinium-based MR contrast agents (GBCA) at high concentrations during a dual injection of GBCA and PET radiotracer may cause increased attenuation effects of the PET signal, and thus errors in quantification of PET images. We thus aimed to calculate the change in linear attenuation coefficient (LAC) of a mixture of PET radiotracer and increasing concentrations of GBCA in solution and furthermore, to investigate if this change in LAC produced a measurable effect on the image-based PET activity concentration when attenuation corrected by three different AC strategies. We performed simultaneous PET-MR imaging of a phantom in a static scenario using a fixed activity of 40 MBq [18 F]-NaF, water, and an increasing GBCA concentration from 0 to 66 mM (based on an assumed maximum possible concentration of GBCA in the left ventricle in a clinical study). This simulated a range of clinical concentrations of GBCA. We investigated two methods to calculate the LAC of the solution mixture at 511 keV: (1) a mathematical mixture rule and (2) CT imaging of each concentration step and subsequent conversion to LAC at 511 keV. This comparison showed that the ranges of LAC produced by both methods are equivalent with an increase in LAC of the mixed solution of approximately 2% over the range of 0-66 mM. We then employed three different attenuation correction methods to the PET data: (1) each PET scan at a specific millimolar concentration of GBCA corrected by its corresponding CT scan, (2) each PET scan corrected by a CT scan with no GBCA present (i.e., at 0 mM GBCA), and (3) a manually generated attenuation map, whereby all CT voxels in the phantom at 0 mM were replaced by LAC = 0.1 cm -1 . All attenuation correction methods (1-3) were accurate to the true measured activity concentration within 5%, and there were no trends in image-based activity concentrations upon increasing the GBCA concentration of the solution. The presence of high GBCA concentration (representing a worst-case scenario in dynamic cardiac studies) in solution with PET radiotracer produces a minimal effect on attenuation-corrected PET quantification.

  16. Electromechanical Wave Imaging (EWI) validation in all four cardiac chambers with 3D electroanatomic mapping in canines in vivo

    PubMed Central

    Costet, Alexandre; Wan, Elaine; Bunting, Ethan; Grondin, Julien; Garan, Hasan; Konofagou, Elisa

    2016-01-01

    Characterization and mapping of arrhythmias is currently performed through invasive insertion and manipulation of cardiac catheters. Electromechanical wave imaging (EWI) is a non-invasive ultrasound-based imaging technique, which tracks the electromechanical activation that immediately follows electrical activation. Electrical and electromechanical activations were previously found to be linearly correlated in the left ventricle, but the relationship has not yet been investigated in the three other chambers of the heart. The objective of this study was to investigate the relationship between electrical and electromechanical activations and validate EWI in all four chambers of the heart with conventional 3D electroanatomical mapping. Six (n = 6) normal adult canines were used in this study. The electrical activation sequence was mapped in all four chambers of the heart, both endocardially and epicardially using the St Jude's EnSite 3D mapping system (St. Jude Medical, Secaucus, NJ). EWI acquisitions were performed in all four chambers during normal sinus rhythm, and during pacing in the left ventricle. Isochrones of the electromechanical activation were generated from standard echocardiographic imaging views. Electrical and electromechanical activation maps were co-registered and compared, and electrical and electromechanical activation times were plotted against each other and linear regression was performed for each pair of activation maps. Electromechanical and electrical activations were found to be directly correlated with slopes of the correlation ranging from 0.77 to 1.83, electromechanical delays between 9 and 58 ms and R2 values from 0.71 to 0.92. The linear correlation between electrical and electromechanical activations and the agreement between the activation maps indicate that the electromechanical activation follows the pattern of propagation of the electrical activation. This suggests that EWI may be used as a novel non-invasive method to accurately characterize and localize sources of arrhythmias. PMID:27782003

  17. Electromechanical wave imaging (EWI) validation in all four cardiac chambers with 3D electroanatomic mapping in canines in vivo.

    PubMed

    Costet, Alexandre; Wan, Elaine; Bunting, Ethan; Grondin, Julien; Garan, Hasan; Konofagou, Elisa

    2016-11-21

    Characterization and mapping of arrhythmias is currently performed through invasive insertion and manipulation of cardiac catheters. Electromechanical wave imaging (EWI) is a non-invasive ultrasound-based imaging technique, which tracks the electromechanical activation that immediately follows electrical activation. Electrical and electromechanical activations were previously found to be linearly correlated in the left ventricle, but the relationship has not yet been investigated in the three other chambers of the heart. The objective of this study was to investigate the relationship between electrical and electromechanical activations and validate EWI in all four chambers of the heart with conventional 3D electroanatomical mapping. Six (n  =  6) normal adult canines were used in this study. The electrical activation sequence was mapped in all four chambers of the heart, both endocardially and epicardially using the St Jude's EnSite 3D mapping system (St. Jude Medical, Secaucus, NJ). EWI acquisitions were performed in all four chambers during normal sinus rhythm, and during pacing in the left ventricle. Isochrones of the electromechanical activation were generated from standard echocardiographic imaging views. Electrical and electromechanical activation maps were co-registered and compared, and electrical and electromechanical activation times were plotted against each other and linear regression was performed for each pair of activation maps. Electromechanical and electrical activations were found to be directly correlated with slopes of the correlation ranging from 0.77 to 1.83, electromechanical delays between 9 and 58 ms and R 2 values from 0.71 to 0.92. The linear correlation between electrical and electromechanical activations and the agreement between the activation maps indicate that the electromechanical activation follows the pattern of propagation of the electrical activation. This suggests that EWI may be used as a novel non-invasive method to accurately characterize and localize sources of arrhythmias.

  18. Low b-value diffusion-weighted cardiac magnetic resonance imaging: initial results in humans using an optimal time-window imaging approach.

    PubMed

    Rapacchi, Stanislas; Wen, Han; Viallon, Magalie; Grenier, Denis; Kellman, Peter; Croisille, Pierre; Pai, Vinay M

    2011-12-01

    Diffusion-weighted imaging (DWI) using low b-values permits imaging of intravoxel incoherent motion in tissues. However, low b-value DWI of the human heart has been considered too challenging because of additional signal loss due to physiological motion, which reduces both signal intensity and the signal-to-noise ratio (SNR). We address these signal loss concerns by analyzing cardiac motion during a heartbeat to determine the time-window during which cardiac bulk motion is minimal. Using this information to optimize the acquisition of DWI data and combining it with a dedicated image processing approach has enabled us to develop a novel low b-value diffusion-weighted cardiac magnetic resonance imaging approach, which significantly reduces intravoxel incoherent motion measurement bias introduced by motion. Simulations from displacement encoded motion data sets permitted the delineation of an optimal time-window with minimal cardiac motion. A number of single-shot repetitions of low b-value DWI cardiac magnetic resonance imaging data were acquired during this time-window under free-breathing conditions with bulk physiological motion corrected for by using nonrigid registration. Principal component analysis (PCA) was performed on the registered images to improve the SNR, and temporal maximum intensity projection (TMIP) was applied to recover signal intensity from time-fluctuant motion-induced signal loss. This PCATMIP method was validated with experimental data, and its benefits were evaluated in volunteers before being applied to patients. Optimal time-window cardiac DWI in combination with PCATMIP postprocessing yielded significant benefits for signal recovery, contrast-to-noise ratio, and SNR in the presence of bulk motion for both numerical simulations and human volunteer studies. Analysis of mean apparent diffusion coefficient (ADC) maps showed homogeneous values among volunteers and good reproducibility between free-breathing and breath-hold acquisitions. The PCATMIP DWI approach also indicated its potential utility by detecting ADC variations in acute myocardial infarction patients. Studying cardiac motion may provide an appropriate strategy for minimizing the impact of bulk motion on cardiac DWI. Applying PCATMIP image processing improves low b-value DWI and enables reliable analysis of ADC in the myocardium. The use of a limited number of repetitions in a free-breathing mode also enables easier application in clinical conditions.

  19. Cardiac Hypertrophy Is Inhibited by a Local Pool of cAMP Regulated by Phosphodiesterase 2.

    PubMed

    Zoccarato, Anna; Surdo, Nicoletta C; Aronsen, Jan M; Fields, Laura A; Mancuso, Luisa; Dodoni, Giuliano; Stangherlin, Alessandra; Livie, Craig; Jiang, He; Sin, Yuan Yan; Gesellchen, Frank; Terrin, Anna; Baillie, George S; Nicklin, Stuart A; Graham, Delyth; Szabo-Fresnais, Nicolas; Krall, Judith; Vandeput, Fabrice; Movsesian, Matthew; Furlan, Leonardo; Corsetti, Veronica; Hamilton, Graham; Lefkimmiatis, Konstantinos; Sjaastad, Ivar; Zaccolo, Manuela

    2015-09-25

    Chronic elevation of 3'-5'-cyclic adenosine monophosphate (cAMP) levels has been associated with cardiac remodeling and cardiac hypertrophy. However, enhancement of particular aspects of cAMP/protein kinase A signaling seems to be beneficial for the failing heart. cAMP is a pleiotropic second messenger with the ability to generate multiple functional outcomes in response to different extracellular stimuli with strict fidelity, a feature that relies on the spatial segregation of the cAMP pathway components in signaling microdomains. How individual cAMP microdomains affect cardiac pathophysiology remains largely to be established. The cAMP-degrading enzymes phosphodiesterases (PDEs) play a key role in shaping local changes in cAMP. Here we investigated the effect of specific inhibition of selected PDEs on cardiac myocyte hypertrophic growth. Using pharmacological and genetic manipulation of PDE activity, we found that the rise in cAMP resulting from inhibition of PDE3 and PDE4 induces hypertrophy, whereas increasing cAMP levels via PDE2 inhibition is antihypertrophic. By real-time imaging of cAMP levels in intact myocytes and selective displacement of protein kinase A isoforms, we demonstrate that the antihypertrophic effect of PDE2 inhibition involves the generation of a local pool of cAMP and activation of a protein kinase A type II subset, leading to phosphorylation of the nuclear factor of activated T cells. Different cAMP pools have opposing effects on cardiac myocyte cell size. PDE2 emerges as a novel key regulator of cardiac hypertrophy in vitro and in vivo, and its inhibition may have therapeutic applications. © 2015 American Heart Association, Inc.

  20. 18-FDG-PET in a patient cohort suspected for cardiac sarcoidosis: Right ventricular uptake is associated with pathological uptake in mediastinal lymph nodes.

    PubMed

    Tuominen, Heikki; Haarala, Atte; Tikkakoski, Antti; Kähönen, Mika; Nikus, Kjell; Sipilä, Kalle

    2018-05-02

    In up to 65% of cardiac sarcoidosis patients, the disease is confined to the heart. Diagnosing isolated cardiac sarcoidosis is challenging due to the low sensitivity of endomyocardial biopsy. If cardiac sarcoidosis is part of biopsy-confirmed systemic sarcoidosis, the diagnosis can be based on cardiac imaging studies. We compared the imaging features of patients with isolated cardiac FDG uptake on positron emission tomography with those who had findings indicative of systemic sarcoidosis. 137 consecutive cardiac FDG-PET/CT studies performed on subjects suspected of having cardiac sarcoidosis were retrospectively analyzed. 33 patients had pathological left ventricular FDG uptake, and 12 of these also had pathological right ventricular uptake. 16/33 patients with pathological cardiac uptake had pathological extracardiac uptake. 10/12 patients with both LV- and RV-uptake patterns had extracardiac uptake compared to 6/21 of those with pathological LV uptake without RV uptake. SUVmax values in the myocardium were higher among patients with abnormal extracardiac uptake. The presence of extracardiac uptake was the only imaging-related factor that could predict a biopsy indicative of sarcoidosis. Right ventricular involvement seems to be more common in patients who also have findings suggestive of suspected systemic sarcoidosis, compared with patients with PET findings indicative of isolated cardiac disease.

  1. Magnetic Resonance Imaging of Iron Oxide-Labeled Human Embryonic Stem Cell-Derived Cardiac Progenitors.

    PubMed

    Skelton, Rhys J P; Khoja, Suhail; Almeida, Shone; Rapacchi, Stanislas; Han, Fei; Engel, James; Zhao, Peng; Hu, Peng; Stanley, Edouard G; Elefanty, Andrew G; Kwon, Murray; Elliott, David A; Ardehali, Reza

    2016-01-01

    Given the limited regenerative capacity of the heart, cellular therapy with stem cell-derived cardiac cells could be a potential treatment for patients with heart disease. However, reliable imaging techniques to longitudinally assess engraftment of the transplanted cells are scant. To address this issue, we used ferumoxytol as a labeling agent of human embryonic stem cell-derived cardiac progenitor cells (hESC-CPCs) to facilitate tracking by magnetic resonance imaging (MRI) in a large animal model. Differentiating hESCs were exposed to ferumoxytol at different time points and varying concentrations. We determined that treatment with ferumoxytol at 300 μg/ml on day 0 of cardiac differentiation offered adequate cell viability and signal intensity for MRI detection without compromising further differentiation into definitive cardiac lineages. Labeled hESC-CPCs were transplanted by open surgical methods into the left ventricular free wall of uninjured pig hearts and imaged both ex vivo and in vivo. Comprehensive T2*-weighted images were obtained immediately after transplantation and 40 days later before termination. The localization and dispersion of labeled cells could be effectively imaged and tracked at days 0 and 40 by MRI. Thus, under the described conditions, ferumoxytol can be used as a long-term, differentiation-neutral cell-labeling agent to track transplanted hESC-CPCs in vivo using MRI. The development of a safe and reproducible in vivo imaging technique to track the fate of transplanted human embryonic stem cell-derived cardiac progenitor cells (hESC-CPCs) is a necessary step to clinical translation. An iron oxide nanoparticle (ferumoxytol)-based approach was used for cell labeling and subsequent in vivo magnetic resonance imaging monitoring of hESC-CPCs transplanted into uninjured pig hearts. The present results demonstrate the use of ferumoxytol labeling and imaging techniques in tracking the location and dispersion of cell grafts, highlighting its utility in future cardiac stem cell therapy trials. ©AlphaMed Press.

  2. Cardiac imaging at 7 Tesla: Single- and two-spoke radiofrequency pulse design with 16-channel parallel excitation.

    PubMed

    Schmitter, Sebastian; DelaBarre, Lance; Wu, Xiaoping; Greiser, Andreas; Wang, Dingxin; Auerbach, Edward J; Vaughan, J Thomas; Uğurbil, Kâmil; Van de Moortele, Pierre-François

    2013-11-01

    Higher signal to noise ratio (SNR) and improved contrast have been demonstrated at ultra-high magnetic fields (≥7 Tesla [T]) in multiple targets, often with multi-channel transmit methods to address the deleterious impact on tissue contrast due to spatial variations in B1 (+) profiles. When imaging the heart at 7T, however, respiratory and cardiac motion, as well as B0 inhomogeneity, greatly increase the methodological challenge. In this study we compare two-spoke parallel transmit (pTX) RF pulses with static B1 (+) shimming in cardiac imaging at 7T. Using a 16-channel pTX system, slice-selective two-spoke pTX pulses and static B1 (+) shimming were applied in cardiac CINE imaging. B1 (+) and B0 mapping required modified cardiac triggered sequences. Excitation homogeneity and RF energy were compared in different imaging orientations. Two-spoke pulses provide higher excitation homogeneity than B1 (+) shimming, especially in the more challenging posterior region of the heart. The peak value of channel-wise RF energy was reduced, allowing for a higher flip angle, hence increased tissue contrast. Image quality with two-spoke excitation proved to be stable throughout the entire cardiac cycle. Two-spoke pTX excitation has been successfully demonstrated in the human heart at 7T, with improved image quality and reduced RF pulse energy when compared with B1 (+) shimming. Copyright © 2013 Wiley Periodicals, Inc.

  3. Spillover Compensation in the Presence of Respiratory Motion Embedded in SPECT Perfusion Data

    NASA Astrophysics Data System (ADS)

    Pretorius, P. Hendrik; King, Michael A.

    2008-02-01

    Spillover from adjacent significant accumulations of extra-cardiac activity decreases diagnostic accuracy of SPECT perfusion imaging in especially the inferior/septal cardiac region. One method of compensating for the spillover at some location outside of a structure is to estimate it as the counts blurred into this location when a template (3D model) of the structure undergoes simulated imaging followed by reconstruction. The objective of this study was to determine what impact uncorrected respiratory motion has on such spillover compensation of extra-cardiac activity in the right coronary artery (RCA) territory, and if it is possible to use manual segmentation to define the extra-cardiac activity template(s) used in spillover correction. Two separate MCAT phantoms (1283 matrices) were simulated to represent the source and attenuation distributions of patients with and without respiratory motion. For each phantom the heart was modeled: 1) with a normal perfusion pattern and 2) with an RCA defect equal to 50% of the normal myocardium count level. After Monte Carlo simulation of 64times64times120 projections with appropriate noise, data were reconstructed using the rescaled block iterative (RBI) algorithm with 30 subsets and 5 iterations with compensation for attenuation, scatter and resolution. A 3D Gaussian post-filter with a sigma of 0.476 cm was used to suppress noise. Manual segmentation of the liver in filtered emission slices was used to create 3D binary templates. The true liver distribution (with and without respiratory motion included) was also used as binary templates. These templates were projected using a ray-driven projector simulating the imaging system with the exclusion of Compton scatter and reconstructed using the same protocol as for the emission data, excluding scatter compensation. Reconstructed templates were scaled using reconstructed emission count levels from the liver, and spillover subtracted outside the template. It was evident from the polar maps that the manually segmented template reconstructions were unable to remove all the spillover originating in the liver from the inferior wall. This was especially noticeable when a perfusion defect is present. Templates based on the true liver distribution appreciably improved spillover correction. Thus the emerging combined SPECT/CT technology may play a vital role in identifying and segmenting extra-cardiac structures more reliably thereby facilitating spillover correction. This study also indicates that compensation for respiratory motion might play an important role in spillover compensation.

  4. Roles of Sensory Nerves in the Regulation of Radiation-Induced Structural and Functional Changes in the Heart

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sridharan, Vijayalakshmi; Tripathi, Preeti; Sharma, Sunil

    Purpose: Radiation-induced heart disease (RIHD) is a chronic severe side effect of radiation therapy of intrathoracic and chest wall tumors. The heart contains a dense network of sensory neurons that not only are involved in monitoring of cardiac events such as ischemia and reperfusion but also play a role in cardiac tissue homeostasis, preconditioning, and repair. The purpose of this study was to examine the role of sensory nerves in RIHD. Methods and Materials: Male Sprague-Dawley rats were administered capsaicin to permanently ablate sensory nerves, 2 weeks before local image-guided heart x-ray irradiation with a single dose of 21 Gy.more » During the 6 months of follow-up, heart function was assessed with high-resolution echocardiography. At 6 months after irradiation, cardiac structural and molecular changes were examined with histology, immunohistochemistry, and Western blot analysis. Results: Capsaicin pretreatment blunted the effects of radiation on myocardial fibrosis and mast cell infiltration and activity. By contrast, capsaicin pretreatment caused a small but significant reduction in cardiac output 6 months after irradiation. Capsaicin did not alter the effects of radiation on cardiac macrophage number or indicators of autophagy and apoptosis. Conclusions: These results suggest that sensory nerves, although they play a predominantly protective role in radiation-induced cardiac function changes, may eventually enhance radiation-induced myocardial fibrosis and mast cell activity.« less

  5. Image-based models of cardiac structure in health and disease

    PubMed Central

    Vadakkumpadan, Fijoy; Arevalo, Hermenegild; Prassl, Anton J.; Chen, Junjie; Kickinger, Ferdinand; Kohl, Peter; Plank, Gernot; Trayanova, Natalia

    2010-01-01

    Computational approaches to investigating the electromechanics of healthy and diseased hearts are becoming essential for the comprehensive understanding of cardiac function. In this article, we first present a brief review of existing image-based computational models of cardiac structure. We then provide a detailed explanation of a processing pipeline which we have recently developed for constructing realistic computational models of the heart from high resolution structural and diffusion tensor (DT) magnetic resonance (MR) images acquired ex vivo. The presentation of the pipeline incorporates a review of the methodologies that can be used to reconstruct models of cardiac structure. In this pipeline, the structural image is segmented to reconstruct the ventricles, normal myocardium, and infarct. A finite element mesh is generated from the segmented structural image, and fiber orientations are assigned to the elements based on DTMR data. The methods were applied to construct seven different models of healthy and diseased hearts. These models contain millions of elements, with spatial resolutions in the order of hundreds of microns, providing unprecedented detail in the representation of cardiac structure for simulation studies. PMID:20582162

  6. Attenuation correction for flexible magnetic resonance coils in combined magnetic resonance/positron emission tomography imaging.

    PubMed

    Eldib, Mootaz; Bini, Jason; Calcagno, Claudia; Robson, Philip M; Mani, Venkatesh; Fayad, Zahi A

    2014-02-01

    Attenuation correction for magnetic resonance (MR) coils is a new challenge that came about with the development of combined MR and positron emission tomography (PET) imaging. This task is difficult because such coils are not directly visible on either PET or MR acquisitions with current combined scanners and are therefore not easily localized in the field of view. This issue becomes more evident when trying to localize flexible MR coils (eg, cardiac or body matrix coil) that change position and shape from patient to patient and from one imaging session to another. In this study, we proposed a novel method to localize and correct for the attenuation and scatter of a flexible MR cardiac coil, using MR fiducial markers placed on the surface of the coil to allow for accurate registration of a template computed tomography (CT)-based attenuation map. To quantify the attenuation properties of the cardiac coil, a uniform cylindrical water phantom injected with 18F-fluorodeoxyglucose (18F-FDG) was imaged on a sequential MR/PET system with and without the flexible cardiac coil. After establishing the need to correct for the attenuation of the coil, we tested the feasibility of several methods to register a precomputed attenuation map to correct for the attenuation. To accomplish this, MR and CT visible markers were placed on the surface of the cardiac flexible coil. Using only the markers as a driver for registration, the CT image was registered to the reference image through a combination of rigid and deformable registration. The accuracy of several methods was compared for the deformable registration, including B-spline, thin-plate spline, elastic body spline, and volume spline. Finally, we validated our novel approach both in phantom and patient studies. The findings from the phantom experiments indicated that the presence of the coil resulted in a 10% reduction in measured 18F-FDG activity when compared with the phantom-only scan. Local underestimation reached 22% in regions of interest close to the coil. Various registration methods were tested, and the volume spline was deemed to be the most accurate, as measured by the Dice similarity metric. The results of our phantom experiments showed that the bias in the 18F-FDG quantification introduced by the presence of the coil could be reduced by using our registration method. An overestimation of only 1.9% of the overall activity for the phantom scan with the coil attenuation map was measured when compared with the baseline phantom scan without coil. A local overestimation of less than 3% was observed in the ROI analysis when using the proposed method to correct for the attenuation of the flexible cardiac coil. Quantitative results from the patient study agreed well with the phantom findings. We presented and validated an accurate method to localize and register a CT-based attenuation map to correct for the attenuation and scatter of flexible MR coils. This method may be translated to clinical use to produce quantitatively accurate measurements with the use of flexible MR coils during MR/PET imaging.

  7. Current Understanding of the Pathophysiology of Myocardial Fibrosis and Its Quantitative Assessment in Heart Failure

    PubMed Central

    Liu, Tong; Song, Deli; Dong, Jianzeng; Zhu, Pinghui; Liu, Jie; Liu, Wei; Ma, Xiaohai; Zhao, Lei; Ling, Shukuan

    2017-01-01

    Myocardial fibrosis is an important part of cardiac remodeling that leads to heart failure and death. Myocardial fibrosis results from increased myofibroblast activity and excessive extracellular matrix deposition. Various cells and molecules are involved in this process, providing targets for potential drug therapies. Currently, the main detection methods of myocardial fibrosis rely on serum markers, cardiac magnetic resonance imaging, and endomyocardial biopsy. This review summarizes our current knowledge regarding the pathophysiology, quantitative assessment, and novel therapeutic strategies of myocardial fibrosis. PMID:28484397

  8. Cardiac MRI in mice at 9.4 Tesla with a transmit-receive surface coil and a cardiac-tailored intensity-correction algorithm.

    PubMed

    Sosnovik, David E; Dai, Guangping; Nahrendorf, Matthias; Rosen, Bruce R; Seethamraju, Ravi

    2007-08-01

    To evaluate the use of a transmit-receive surface (TRS) coil and a cardiac-tailored intensity-correction algorithm for cardiac MRI in mice at 9.4 Tesla (9.4T). Fast low-angle shot (FLASH) cines, with and without delays alternating with nutations for tailored excitation (DANTE) tagging, were acquired in 13 mice. An intensity-correction algorithm was developed to compensate for the sensitivity profile of the surface coil, and was tailored to account for the unique distribution of noise and flow artifacts in cardiac MR images. Image quality was extremely high and allowed fine structures such as trabeculations, valve cusps, and coronary arteries to be clearly visualized. The tag lines created with the surface coil were also sharp and clearly visible. Application of the intensity-correction algorithm improved signal intensity, tissue contrast, and image quality even further. Importantly, the cardiac-tailored properties of the correction algorithm prevented noise and flow artifacts from being significantly amplified. The feasibility and value of cardiac MRI in mice with a TRS coil has been demonstrated. In addition, a cardiac-tailored intensity-correction algorithm has been developed and shown to improve image quality even further. The use of these techniques could produce significant potential benefits over a broad range of scanners, coil configurations, and field strengths. (c) 2007 Wiley-Liss, Inc.

  9. Inter- and Intraobserver Agreement of 18F-FDG PET/CT Image Interpretation in Patients Referred for Assessment of Cardiac Sarcoidosis.

    PubMed

    Ohira, Hiroshi; Ardle, Brian Mc; deKemp, Robert A; Nery, Pablo; Juneau, Daniel; Renaud, Jennifer M; Klein, Ran; Clarkin, Owen; MacDonald, Karen; Leung, Eugene; Nair, Girish; Beanlands, Rob; Birnie, David

    2017-08-01

    Recent studies have reported the usefulness of 18 F-FDG PET in aiding with the diagnosis and management of patients with cardiac sarcoidosis (CS). However, image interpretation of 18 F-FDG PET for CS is sometimes challenging. We sought to investigate the inter- and intraobserver agreement and explore factors that led to important discrepancies between readers. Methods: We studied consecutive patients with no significant coronary artery disease who were referred for assessment of CS. Two experienced readers masked to clinical information, imaging reports, independently reviewed 18 F-FDG PET/CT images. 18 F-FDG PET/CT images were interpreted according to a predefined standard operating procedure, with cardiac 18 F-FDG uptake patterns categorized into 5 patterns: none, focal, focal on diffuse, diffuse, and isolated lateral wall or basal uptake. Overall image assessment was classified as either consistent with active CS or not. Results: One hundred scans were included from 71 patients. Of these, 46 underwent 18 F-FDG PET/CT with a no-restriction diet (no-restriction group), and 54 underwent 18 F-FDG PET/CT with a low-carbohydrate, high-fat and protein-permitted diet (low-carb group). There was agreement of the interpretation category in 74 of 100 scans. The κ-value of agreement among all 5 categories was 0.64, indicating moderate agreement. For overall clinical interpretation, there was agreement in 93 of 100 scans (κ = 0.85). When scans were divided into the preparation groups, there was a trend toward higher agreement in the low-carb group versus the no-restriction group (80% vs. 67%, P = 0.08). Regarding the overall clinical interpretation, there was also a trend toward greater agreement in the low-carb group versus the no-restriction group (96% vs. 89%, P = 0.08). Conclusion : The interobserver agreement of cardiac 18 F-FDG uptake image patterns was moderate. However, agreement was better regarding overall interpretation of CS. Detailed prescan dietary preparation seemed to improve interobserver agreement. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  10. Image-guided optimization of the ECG trace in cardiac MRI.

    PubMed

    Barnwell, James D; Klein, J Larry; Stallings, Cliff; Sturm, Amanda; Gillespie, Michael; Fine, Jason; Hyslop, W Brian

    2012-03-01

    Improper electrocardiogram (ECG) lead placement resulting in suboptimal gating may lead to reduced image quality in cardiac magnetic resonance imaging (CMR). A patientspecific systematic technique for rapid optimization of lead placement may improve CMR image quality. A rapid 3 dimensional image of the thorax was used to guide the realignment of ECG leads relative to the cardiac axis of the patient in forty consecutive adult patients. Using our novel approach and consensus reading of pre- and post-correction ECG traces, seventy-three percent of patients had a qualitative improvement in their ECG tracings, and no patient had a decrease in quality of their ECG tracing following the correction technique. Statistically significant improvement was observed independent of gender, body mass index, and cardiac rhythm. This technique provides an efficient option to improve the quality of the ECG tracing in patients who have a poor quality ECG with standard techniques.

  11. Contrast-enhanced cardiac C-arm CT evaluation of radiofrequency ablation lesions in the left ventricle

    PubMed Central

    Girard, Erin E; Al-Ahmad, Amin A; Rosenberg, Jarrett; Luong, Richard; Moore, Teri; Lauritsch, Günter; Boese, Jan; Fahrig, Rebecca

    2011-01-01

    Objectives The purpose of this study was to evaluate use of cardiac C-arm computed tomography (CT) in the assessment of the dimensions and temporal characteristics of radiofrequency ablation (RFA) lesions. This imaging modality uses a standard C-arm fluoroscopy system rotating around the patient, providing CT-like images during the RFA procedure. Background Both magnetic resonance imaging (MRI) and CT can be used to assess myocardial necrotic tissue. Several studies have reported visualizing cardiac RF ablation lesions with MRI, however obtaining MR images during interventional procedures is not common practice. Direct visualization of RFA lesions using C-arm CT during the procedure may improve outcomes and circumvent complications associated with cardiac ablation procedures. Methods RFA lesions were created on the endocardial surface of the left ventricle of 9 swine using a 7-F RF ablation catheter. An ECG-gated C-arm CT imaging protocol was used to acquire projection images during iodine contrast injection and following the injection every 5 min for up to 30 min, with no additional contrast. Reconstructed images were analyzed offline. The mean and standard deviation of the signal intensity of the lesion and normal myocardium were measured in all images in each time series. Lesion dimensions and area were measured and compared in pathologic specimens and C-arm CT images. Results All ablation lesions (n=29) were visualized and lesion dimensions, as measured on C-arm CT, correlated well with postmortem tissue measurements (1D dimensions : concordance correlation = 0.87; area : concordance correlation = 0.90). Lesions were visualized as a perfusion defect on first-pass C-arm CT images with a signal intensity 95 HU lower than normal myocardium (95% confidence interval: -111 to -79 HU). Images acquired at 1 and 5 minutes exhibited an enhancing ring surrounding the perfusion defect in 24 (83%) lesions. Conclusions RFA lesion size, including transmurality, can be assessed using ECG-gated cardiac C-arm CT in the interventional suite. Visualization of RFA lesions using cardiac C-arm CT may facilitate the assessment of adequate lesion delivery and provide valuable feedback during cardiac ablation procedures. PMID:21414574

  12. Magnetic Resonance Imaging (MRI) for the Assessment of Myocardial Viability

    PubMed Central

    2010-01-01

    Executive Summary In July 2009, the Medical Advisory Secretariat (MAS) began work on Non-Invasive Cardiac Imaging Technologies for the Assessment of Myocardial Viability, an evidence-based review of the literature surrounding different cardiac imaging modalities to ensure that appropriate technologies are accessed by patients undergoing viability assessment. This project came about when the Health Services Branch at the Ministry of Health and Long-Term Care asked MAS to provide an evidentiary platform on effectiveness and cost-effectiveness of noninvasive cardiac imaging modalities. After an initial review of the strategy and consultation with experts, MAS identified five key non-invasive cardiac imaging technologies that can be used for the assessment of myocardial viability: positron emission tomography, cardiac magnetic resonance imaging, dobutamine echocardiography, and dobutamine echocardiography with contrast, and single photon emission computed tomography. A 2005 review conducted by MAS determined that positron emission tomography was more sensitivity than dobutamine echocardiography and single photon emission tomography and dominated the other imaging modalities from a cost-effective standpoint. However, there was inadequate evidence to compare positron emission tomography and cardiac magnetic resonance imaging. Thus, this report focuses on this comparison only. For both technologies, an economic analysis was also completed. A summary decision analytic model was then developed to encapsulate the data from each of these reports (available on the OHTAC and MAS website). The Non-Invasive Cardiac Imaging Technologies for the Assessment of Myocardial Viability is made up of the following reports, which can be publicly accessed at the MAS website at: www.health.gov.on.ca/mas or at www.health.gov.on.ca/english/providers/program/mas/mas_about.html Positron Emission Tomography for the Assessment of Myocardial Viability: An Evidence-Based Analysis Magnetic Resonance Imaging for the Assessment of Myocardial Viability: An Evidence-Based Analysis Objective The objective of this analysis is to assess the effectiveness and cost-effectiveness of cardiovascular magnetic resonance imaging (cardiac MRI) for the assessment of myocardial viability. To evaluate the effectiveness of cardiac MRI viability imaging, the following outcomes were examined: the diagnostic accuracy in predicting functional recovery and the impact of cardiac MRI viability imaging on prognosis (mortality and other patient outcomes). Clinical Need: Condition and Target Population Left Ventricular Systolic Dysfunction and Heart Failure Heart failure is a complex syndrome characterized by the heart’s inability to maintain adequate blood circulation through the body leading to multiorgan abnormalities and, eventually, death. Patients with heart failure experience poor functional capacity, decreased quality of life, and increased risk of morbidity and mortality. In 2005, more than 71,000 Canadians died from cardiovascular disease, of which, 54% were due to ischemic heart disease. Left ventricular (LV) systolic dysfunction due to coronary artery disease (CAD) 1 is the primary cause of heart failure accounting for more than 70% of cases. The prevalence of heart failure was estimated at one percent of the Canadian population in 1989. Since then, the increase in the older population has undoubtedly resulted in a substantial increase in cases. Heart failure is associated with a poor prognosis: one-year mortality rates were 32.9% and 31.1% for men and women, respectively in Ontario between 1996 and 1997. Treatment Options In general, there are three options for the treatment of heart failure: medical treatment, heart transplantation, and revascularization for those with CAD as the underlying cause. Concerning medical treatment, despite recent advances, mortality remains high among treated patients, while, heart transplantation is affected by the limited availability of donor hearts and consequently has long waiting lists. The third option, revascularization, is used to restore the flow of blood to the heart via coronary artery bypass grafting (CABG) or, in some cases, through minimally invasive percutaneous coronary interventions (balloon angioplasty and stenting). Both methods, however, are associated with important perioperative risks including mortality, so it is essential to properly select patients for this procedure. Myocardial Viability Left ventricular dysfunction may be permanent, due to the formation of myocardial scar, or it may be reversible after revascularization. Reversible LV dysfunction occurs when the myocardium is viable but dysfunctional (reduced contractility). Since only patients with dysfunctional but viable myocardium benefit from revascularization, the identification and quantification of the extent of myocardial viability is an important part of the work-up of patients with heart failure when determining the most appropriate treatment path. Various non-invasive cardiac imaging modalities can be used to assess patients in whom determination of viability is an important clinical issue, specifically: dobutamine echocardiography (echo), stress echo with contrast, SPECT using either technetium or thallium, cardiac magnetic resonance imaging (cardiac MRI), and positron emission tomography (PET). Dobutamine Echocardiography Stress echocardiography can be used to detect viable myocardium. During the infusion of low dose dobutamine (5 – 10 µg/kg/min), an improvement of contractility in hypokinetic and akentic segments is indicative of the presence of viable myocardium. Alternatively, a low-high dose dobutamine protocol can be used in which a biphasic response characterized by improved contractile function during the low-dose infusion followed by a deterioration in contractility due to stress induced ischemia during the high dose dobutamine infusion (dobutamine dose up to 40 ug/kg/min) represents viable tissue. Newer techniques including echocardiography using contrast agents, harmonic imaging, and power doppler imaging may help to improve the diagnostic accuracy of echocardiographic assessment of myocardial viability. Stress Echocardiography with Contrast Intravenous contrast agents, which are high molecular weight inert gas microbubbles that act like red blood cells in the vascular space, can be used during echocardiography to assess myocardial viability. These agents allow for the assessment of myocardial blood flow (perfusion) and contractile function (as described above), as well as the simultaneous assessment of perfusion to make it possible to distinguish between stunned and hibernating myocardium. SPECT SPECT can be performed using thallium-201 (Tl-201), a potassium analogue, or technetium-99 m labelled tracers. When Tl-201 is injected intravenously into a patient, it is taken up by the myocardial cells through regional perfusion, and Tl-201 is retained in the cell due to sodium/potassium ATPase pumps in the myocyte membrane. The stress-redistribution-reinjection protocol involves three sets of images. The first two image sets (taken immediately after stress and then three to four hours after stress) identify perfusion defects that may represent scar tissue or viable tissue that is severely hypoperfused. The third set of images is taken a few minutes after the re-injection of Tl-201 and after the second set of images is completed. These re-injection images identify viable tissue if the defects exhibit significant fill-in (> 10% increase in tracer uptake) on the re-injection images. The other common Tl-201 viability imaging protocol, rest-redistribution, involves SPECT imaging performed at rest five minutes after Tl-201 is injected and again three to four hours later. Viable tissue is identified if the delayed images exhibit significant fill-in of defects identified in the initial scans (> 10% increase in uptake) or if defects are fixed but the tracer activity is greater than 50%. There are two technetium-99 m tracers: sestamibi (MIBI) and tetrofosmin. The uptake and retention of these tracers is dependent on regional perfusion and the integrity of cellular membranes. Viability is assessed using one set of images at rest and is defined by segments with tracer activity greater than 50%. Cardiac Positron Emission Tomography Positron emission tomography (PET) is a nuclear medicine technique used to image tissues based on the distinct ways in which normal and abnormal tissues metabolize positron-emitting radionuclides. Radionuclides are radioactive analogs of common physiological substrates such as sugars, amino acids, and free fatty acids that are used by the body. The only licensed radionuclide used in PET imaging for viability assessment is F-18 fluorodeoxyglucose (FDG). During a PET scan, the radionuclides are injected into the body and as they decay, they emit positively charged particles (positrons) that travel several millimetres into tissue and collide with orbiting electrons. This collision results in annihilation where the combined mass of the positron and electron is converted into energy in the form of two 511 keV gamma rays, which are then emitted in opposite directions (180 degrees) and captured by an external array of detector elements in the PET gantry. Computer software is then used to convert the radiation emission into images. The system is set up so that it only detects coincident gamma rays that arrive at the detectors within a predefined temporal window, while single photons arriving without a pair or outside the temporal window do not active the detector. This allows for increased spatial and contrast resolution. Cardiac Magnetic Resonance Imaging Cardiac magnetic resonance imaging (cardiac MRI) is a non-invasive, x-ray free technique that uses a powerful magnetic field, radio frequency pulses, and a computer to produce detailed images of the structure and function of the heart. Two types of cardiac MRI are used to assess myocardial viability: dobutamine stress magnetic resonance imaging (DSMR) and delayed contrast-enhanced cardiac MRI (DE-MRI). DE-MRI, the most commonly used technique in Ontario, uses gadolinium-based contrast agents to define the transmural extent of scar, which can be visualized based on the intensity of the image. Hyper-enhanced regions correspond to irreversibly damaged myocardium. As the extent of hyper-enhancement increases, the amount of scar increases, so there is a lower the likelihood of functional recovery. Evidence-Based Analysis Research Questions What is the diagnostic accuracy of cardiac MRI for detecting myocardial viability? What is the impact of cardiac MRI viability imaging on prognosis (mortality and other clinical outcomes)? How does cardiac MRI compare with cardiac PET imaging for the assessment of myocardial viability? What is the contribution of cardiac MRI viability imaging to treatment decision making? Is cardiac MRI cost-effective compared with other cardiac imaging modalities for the assessment of myocardial viability? Literature Search A literature search was performed on October 9, 2009 using OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, EMBASE, the Cochrane Library, and the International Agency for Health Technology Assessment (INAHTA) for studies published from January 1, 2005 until October 9, 2009. Abstracts were reviewed by a single reviewer and, for those studies meeting the eligibility criteria full-text articles were obtained. In addition, published systematic reviews and health technology assessments were reviewed for relevant studies published before 2005. Reference lists were also examined for any additional relevant studies not identified through the search. The quality of evidence was assessed as high, moderate, low or very low according to GRADE methodology. Inclusion Criteria English language full-reports Published between January 1, 2005 and October 9, 2009 Health technology assessments, systematic reviews, meta-analyses, randomized controlled trials (RCTs), and observational studies Patients with chronic, known coronary artery disease (CAD) Used contrast-enhanced MRI Assessment of functional recovery ≥ 3 months after revascularization Exclusion Criteria < 20 patients < 18 years of age Patients with non-ischemic heart disease Studies conducted exclusively in patients with acute myocardial infarction (MI) Studies where TP, TN, FP, FN cannot be determined Outcomes of Interest Sensitivity Specificity Positive predictive value (PPV) Negative Predictive value (NPV) Positive likelihood ratio Negative likelihood ratio Diagnostic accuracy Mortality rate (for prognostic studies) Adverse events Summary of Findings Based on the available very low quality evidence, MRI is a useful imaging modality for the detection of viable myocardium. The pooled estimates of sensitivity and specificity for the prediction of regional functional recovery as a surrogate for viable myocardium are 84.5% (95% CI: 77.5% – 91.6%) and 71.0% (95% CI: 68.8% – 79.2%), respectively. Subgroup analysis demonstrated a statistically significant difference in the sensitivity of MRI to assess myocardial viability for studies using ≤25% hyperenhancement as a viability threshold versus studies using ≤50% hyperenhancement as their viability threshold [78.7 (95% CI: 69.1% - 88.2%) and 96.2 (95% CI: 91.8 – 100.6); p=0.0044 respectively]. Marked differences in specificity were observed [73.6 (95% CI: 62.6% - 84.6%) and 47.2 (95% CI: 22.2 – 72.3); p=0.2384 respectively]; however, these findings were not statistically significant. There were no statistically significant differences between the sensitivities or specificities for any other subgroups including mean preoperative LVEF, imaging method for function recovery assessment, and length of follow-up. There was no evidence available to determine whether patients with viable myocardium who are revascularized have a lower mortality rate than those who are treated with medical therapy. PMID:23074392

  13. Self-gated fetal cardiac MRI with tiny golden angle iGRASP: A feasibility study.

    PubMed

    Haris, Kostas; Hedström, Erik; Bidhult, Sebastian; Testud, Frederik; Maglaveras, Nicos; Heiberg, Einar; Hansson, Stefan R; Arheden, Håkan; Aletras, Anthony H

    2017-07-01

    To develop and assess a technique for self-gated fetal cardiac cine magnetic resonance imaging (MRI) using tiny golden angle radial sampling combined with iGRASP (iterative Golden-angle RAdial Sparse Parallel) for accelerated acquisition based on parallel imaging and compressed sensing. Fetal cardiac data were acquired from five volunteers in gestational week 29-37 at 1.5T using tiny golden angles for eddy currents reduction. The acquired multicoil radial projections were input to a principal component analysis-based compression stage. The cardiac self-gating (CSG) signal for cardiac gating was extracted from the acquired radial projections and the iGRASP reconstruction procedure was applied. In all acquisitions, a total of 4000 radial spokes were acquired within a breath-hold of less than 15 seconds using a balanced steady-state free precession pulse sequence. The images were qualitatively compared by two independent observers (on a scale of 1-4) to a single midventricular cine image from metric optimized gating (MOG) and real-time acquisitions. For iGRASP and MOG images, good overall image quality (2.8 ± 0.4 and 2.6 ± 1.3, respectively, for observer 1; 3.6 ± 0.5 and 3.4 ± 0.9, respectively, for observer 2) and cardiac diagnostic quality (3.8 ± 0.4 and 3.4 ± 0.9, respectively, for observer 1; 3.6 ± 0.5 and 3.6 ± 0.9, respectively, for observer 2) were obtained, with visualized myocardial thickening over the cardiac cycle and well-defined myocardial borders to ventricular lumen and liver/lung tissue. For iGRASP, MOG, and real time, left ventricular lumen diameter (14.1 ± 2.2 mm, 14.2 ± 1.9 mm, 14.7 ± 1.1 mm, respectively) and wall thickness (2.7 ± 0.3 mm, 2.6 ± 0.3 mm, 3.0 ± 0.4, respectively) showed agreement and no statistically significant difference was found (all P > 0.05). Images with iGRASP tended to have higher overall image quality scores compared with MOG and particularly real-time images, albeit not statistically significant in this feasibility study (P > 0.99 and P = 0.12, respectively). Fetal cardiac cine MRI can be performed with iGRASP using tiny golden angles and CSG. Comparison with other fetal cardiac cine MRI methods showed that the proposed method produces high-quality fetal cardiac reconstructions. 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:207-217. © 2017 International Society for Magnetic Resonance in Medicine.

  14. A cardiac giant hydatid cyst of the interventricular septum masquerading as ischemic heart disease: role of MR imaging.

    PubMed

    Unal, M; Tuncer, C; Serçe, K; Bostan, M; Erem, C; Gökçe, M

    1995-01-01

    Cardiac echinococcosis is a very rare disease, especially in girls. We report a case of interventricular septum echinococcosis. A 14-year-old girl was referred for chest pain. Magnetic resonance imaging and two-dimensional echocardiography revealed a cyst in the distal interventricular septum. We concluded that MR imaging is useful in diagnosis and planning of surgery. Cardiac hydatid cyst should be considered in the differential diagnosis of patients with anginalike pain in endemic areas.

  15. Magnetic resonance imaging (MRI) for the assessment of myocardial viability: an evidence-based analysis.

    PubMed

    2010-01-01

    In July 2009, the Medical Advisory Secretariat (MAS) began work on Non-Invasive Cardiac Imaging Technologies for the Assessment of Myocardial Viability, an evidence-based review of the literature surrounding different cardiac imaging modalities to ensure that appropriate technologies are accessed by patients undergoing viability assessment. This project came about when the Health Services Branch at the Ministry of Health and Long-Term Care asked MAS to provide an evidentiary platform on effectiveness and cost-effectiveness of noninvasive cardiac imaging modalities.After an initial review of the strategy and consultation with experts, MAS identified five key non-invasive cardiac imaging technologies that can be used for the assessment of myocardial viability: positron emission tomography, cardiac magnetic resonance imaging, dobutamine echocardiography, and dobutamine echocardiography with contrast, and single photon emission computed tomography.A 2005 review conducted by MAS determined that positron emission tomography was more sensitivity than dobutamine echocardiography and single photon emission tomography and dominated the other imaging modalities from a cost-effective standpoint. However, there was inadequate evidence to compare positron emission tomography and cardiac magnetic resonance imaging. Thus, this report focuses on this comparison only. For both technologies, an economic analysis was also completed.A summary decision analytic model was then developed to encapsulate the data from each of these reports (available on the OHTAC and MAS website).The Non-Invasive Cardiac Imaging Technologies for the Assessment of Myocardial Viability is made up of the following reports, which can be publicly accessed at the MAS website at: www.health.gov.on.ca/mas or at www.health.gov.on.ca/english/providers/program/mas/mas_about.htmlPOSITRON EMISSION TOMOGRAPHY FOR THE ASSESSMENT OF MYOCARDIAL VIABILITY: An Evidence-Based AnalysisMAGNETIC RESONANCE IMAGING FOR THE ASSESSMENT OF MYOCARDIAL VIABILITY: An Evidence-Based Analysis The objective of this analysis is to assess the effectiveness and cost-effectiveness of cardiovascular magnetic resonance imaging (cardiac MRI) for the assessment of myocardial viability. To evaluate the effectiveness of cardiac MRI viability imaging, the following outcomes were examined: the diagnostic accuracy in predicting functional recovery and the impact of cardiac MRI viability imaging on prognosis (mortality and other patient outcomes). CONDITION AND TARGET POPULATION LEFT VENTRICULAR SYSTOLIC DYSFUNCTION AND HEART FAILURE: Heart failure is a complex syndrome characterized by the heart's inability to maintain adequate blood circulation through the body leading to multiorgan abnormalities and, eventually, death. Patients with heart failure experience poor functional capacity, decreased quality of life, and increased risk of morbidity and mortality. In 2005, more than 71,000 Canadians died from cardiovascular disease, of which, 54% were due to ischemic heart disease. Left ventricular (LV) systolic dysfunction due to coronary artery disease (CAD) () is the primary cause of heart failure accounting for more than 70% of cases. The prevalence of heart failure was estimated at one percent of the Canadian population in 1989. Since then, the increase in the older population has undoubtedly resulted in a substantial increase in cases. Heart failure is associated with a poor prognosis: one-year mortality rates were 32.9% and 31.1% for men and women, respectively in Ontario between 1996 and 1997. IN GENERAL, THERE ARE THREE OPTIONS FOR THE TREATMENT OF HEART FAILURE: medical treatment, heart transplantation, and revascularization for those with CAD as the underlying cause. Concerning medical treatment, despite recent advances, mortality remains high among treated patients, while, heart transplantation is affected by the limited availability of donor hearts and consequently has long waiting lists. The third option, revascularization, is used to restore the flow of blood to the heart via coronary artery bypass grafting (CABG) or, in some cases, through minimally invasive percutaneous coronary interventions (balloon angioplasty and stenting). Both methods, however, are associated with important perioperative risks including mortality, so it is essential to properly select patients for this procedure. Left ventricular dysfunction may be permanent, due to the formation of myocardial scar, or it may be reversible after revascularization. Reversible LV dysfunction occurs when the myocardium is viable but dysfunctional (reduced contractility). Since only patients with dysfunctional but viable myocardium benefit from revascularization, the identification and quantification of the extent of myocardial viability is an important part of the work-up of patients with heart failure when determining the most appropriate treatment path. Various non-invasive cardiac imaging modalities can be used to assess patients in whom determination of viability is an important clinical issue, specifically: dobutamine echocardiography (echo),stress echo with contrast,SPECT using either technetium or thallium,cardiac magnetic resonance imaging (cardiac MRI), andpositron emission tomography (PET). Stress echocardiography can be used to detect viable myocardium. During the infusion of low dose dobutamine (5 - 10 µg/kg/min), an improvement of contractility in hypokinetic and akentic segments is indicative of the presence of viable myocardium. Alternatively, a low-high dose dobutamine protocol can be used in which a biphasic response characterized by improved contractile function during the low-dose infusion followed by a deterioration in contractility due to stress induced ischemia during the high dose dobutamine infusion (dobutamine dose up to 40 ug/kg/min) represents viable tissue. Newer techniques including echocardiography using contrast agents, harmonic imaging, and power doppler imaging may help to improve the diagnostic accuracy of echocardiographic assessment of myocardial viability. Intravenous contrast agents, which are high molecular weight inert gas microbubbles that act like red blood cells in the vascular space, can be used during echocardiography to assess myocardial viability. These agents allow for the assessment of myocardial blood flow (perfusion) and contractile function (as described above), as well as the simultaneous assessment of perfusion to make it possible to distinguish between stunned and hibernating myocardium. SPECT: SPECT can be performed using thallium-201 (Tl-201), a potassium analogue, or technetium-99 m labelled tracers. When Tl-201 is injected intravenously into a patient, it is taken up by the myocardial cells through regional perfusion, and Tl-201 is retained in the cell due to sodium/potassium ATPase pumps in the myocyte membrane. The stress-redistribution-reinjection protocol involves three sets of images. The first two image sets (taken immediately after stress and then three to four hours after stress) identify perfusion defects that may represent scar tissue or viable tissue that is severely hypoperfused. The third set of images is taken a few minutes after the re-injection of Tl-201 and after the second set of images is completed. These re-injection images identify viable tissue if the defects exhibit significant fill-in (> 10% increase in tracer uptake) on the re-injection images. The other common Tl-201 viability imaging protocol, rest-redistribution, involves SPECT imaging performed at rest five minutes after Tl-201 is injected and again three to four hours later. Viable tissue is identified if the delayed images exhibit significant fill-in of defects identified in the initial scans (> 10% increase in uptake) or if defects are fixed but the tracer activity is greater than 50%. There are two technetium-99 m tracers: sestamibi (MIBI) and tetrofosmin. The uptake and retention of these tracers is dependent on regional perfusion and the integrity of cellular membranes. Viability is assessed using one set of images at rest and is defined by segments with tracer activity greater than 50%. Positron emission tomography (PET) is a nuclear medicine technique used to image tissues based on the distinct ways in which normal and abnormal tissues metabolize positron-emitting radionuclides. Radionuclides are radioactive analogs of common physiological substrates such as sugars, amino acids, and free fatty acids that are used by the body. The only licensed radionuclide used in PET imaging for viability assessment is F-18 fluorodeoxyglucose (FDG). During a PET scan, the radionuclides are injected into the body and as they decay, they emit positively charged particles (positrons) that travel several millimetres into tissue and collide with orbiting electrons. This collision results in annihilation where the combined mass of the positron and electron is converted into energy in the form of two 511 keV gamma rays, which are then emitted in opposite directions (180 degrees) and captured by an external array of detector elements in the PET gantry. Computer software is then used to convert the radiation emission into images. The system is set up so that it only detects coincident gamma rays that arrive at the detectors within a predefined temporal window, while single photons arriving without a pair or outside the temporal window do not active the detector. This allows for increased spatial and contrast resolution. Cardiac magnetic resonance imaging (cardiac MRI) is a non-invasive, x-ray free technique that uses a powerful magnetic field, radio frequency pulses, and a computer to produce detailed images of the structure and function of the heart. (ABSTRACT TRUNCATED)

  16. Genetic modification of embryonic stem cells with VEGF enhances cell survival and improves cardiac function.

    PubMed

    Xie, Xiaoyan; Cao, Feng; Sheikh, Ahmad Y; Li, Zongjin; Connolly, Andrew J; Pei, Xuetao; Li, Ren-Ke; Robbins, Robert C; Wu, Joseph C

    2007-01-01

    Cardiac stem cell therapy remains hampered by acute donor cell death posttransplantation and the lack of reliable methods for tracking cell survival in vivo. We hypothesize that cells transfected with inducible vascular endothelial growth factor 165 (VEGF(165)) can improve their survival as monitored by novel molecular imaging techniques. Mouse embryonic stem (ES) cells were transfected with an inducible, bidirectional tetracycline (Bi-Tet) promoter driving VEGF(165) and renilla luciferase (Rluc). Addition of doxycycline induced Bi-Tet expression of VEGF(165) and Rluc significantly compared to baseline (p<0.05). Expression of VEGF(165) enhanced ES cell proliferation and inhibited apoptosis as determined by Annexin-V staining. For noninvasive imaging, ES cells were transduced with a double fusion (DF) reporter gene consisting of firefly luciferase and enhanced green fluorescence protein (Fluc-eGFP). There was a robust correlation between cell number and Fluc activity (R(2)=0.99). Analysis by immunostaining, histology, and RT-PCR confirmed that expression of Bi-Tet and DF systems did not affect ES cell self-renewal or pluripotency. ES cells were differentiated into beating embryoid bodies expressing cardiac markers such as troponin, Nkx2.5, and beta-MHC. Afterward, 5 x 10(5) cells obtained from these beating embryoid bodies or saline were injected into the myocardium of SV129 mice (n=36) following ligation of the left anterior descending (LAD) artery. Bioluminescence imaging (BLI) and echocardiography showed that VEGF(165) induction led to significant improvements in both transplanted cell survival and cardiac function (p<0.05). This is the first study to demonstrate imaging of embryonic stem cell-mediated gene therapy targeting cardiovascular disease. With further validation, this platform may have broad applications for current basic research and further clinical studies.

  17. Recent technological advancements in cardiac ultrasound imaging.

    PubMed

    Dave, Jaydev K; Mc Donald, Maureen E; Mehrotra, Praveen; Kohut, Andrew R; Eisenbrey, John R; Forsberg, Flemming

    2018-03-01

    About 92.1 million Americans suffer from at least one type of cardiovascular disease. Worldwide, cardiovascular diseases are the number one cause of death (about 31% of all global deaths). Recent technological advancements in cardiac ultrasound imaging are expected to aid in the clinical diagnosis of many cardiovascular diseases. This article provides an overview of such recent technological advancements, specifically focusing on tissue Doppler imaging, strain imaging, contrast echocardiography, 3D echocardiography, point-of-care echocardiography, 3D volumetric flow assessments, and elastography. With these advancements ultrasound imaging is rapidly changing the domain of cardiac imaging. The advantages offered by ultrasound imaging include real-time imaging, imaging at patient bed-side, cost-effectiveness and ionizing-radiation-free imaging. Along with these advantages, the steps taken towards standardization of ultrasound based quantitative markers, reviewed here, will play a major role in addressing the healthcare burden associated with cardiovascular diseases. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. [High non-specific binding of the beta(1) -selective radioligand 2-(125)I-ICI-H].

    PubMed

    Riemann, B; Law, M P; Kopka, K; Wagner, St; Luthra, S; Pike, V W; Neumann, J; Kirchhefer, U; Schmitz, W; Schober, O; Schäfers, M

    2003-08-01

    As results of cardiac biopsies suggest, myocardial beta(1) -adrenoceptor density is reduced in patients with chronic heart failure. However, changes in cardiac beta(2)-adrenoceptors vary. With suitable radiopharmaceuticals single photon emission computed tomography (SPECT) and positron emission tomography (PET) offer the opportunity to assess beta-adrenoceptors non-invasively. Among the novel racemic analogues of the established beta(1)-selective adrenoceptor antagonist ICI 89.406 the iodinated 2-I-ICI-H showed high affinity and selectivity to beta(1)-adrenoceptors in murine ventricular membranes. The aim of this study was its evaluation as a putative sub-type selective beta(1)-adrenergic radioligand in cardiac imaging. Competition studies in vitro and in vivo were used to investigate the kinetics of 2-I-ICI-H binding to cardiac beta-adrenoceptors in mice and rats. In addition, the radiosynthesis of 2-(125)I-ICI-H from the silylated precursor 2-SiMe(3)-ICI-H was established. The specific activity was 80 GBq/ micro mol, the radiochemical yield ranged from 70 to 80%. The unlabelled compound 2-I-ICI-H showed high beta(1)-selectivity and -affinity in the in vitro competition studies. In vivo biodistribution studies apparently showed low affinity to cardiac beta-adrenoceptors. The radiolabelled counterpart 2-(125)I-ICI-H showed a high degree of non-specific binding in vitro and no specific binding to cardiac beta(1)-adrenoceptors in vivo. Because of its high non-specific binding 2-(125)I-ICI-H is no suitable radiotracer for imaging in vivo.

  19. Thermal Infrared Imaging-Based Computational Psychophysiology for Psychometrics

    PubMed Central

    Cardone, Daniela; Pinti, Paola; Merla, Arcangelo

    2015-01-01

    Thermal infrared imaging has been proposed as a potential system for the computational assessment of human autonomic nervous activity and psychophysiological states in a contactless and noninvasive way. Through bioheat modeling of facial thermal imagery, several vital signs can be extracted, including localized blood perfusion, cardiac pulse, breath rate, and sudomotor response, since all these parameters impact the cutaneous temperature. The obtained physiological information could then be used to draw inferences about a variety of psychophysiological or affective states, as proved by the increasing number of psychophysiological studies using thermal infrared imaging. This paper presents therefore a review of the principal achievements of thermal infrared imaging in computational physiology with regard to its capability of monitoring psychophysiological activity. PMID:26339284

  20. Cardiac manifestations of sarcoidosis: diagnosis and management.

    PubMed

    Birnie, David H; Kandolin, Riina; Nery, Pablo B; Kupari, Markku

    2017-09-14

    Approximately 5% of patients with sarcoidosis will have clinically manifest cardiac involvement presenting with one or more of ventricular arrhythmias, conduction abnormalities, and heart failure. Cardiac presentations can be the first (and/or an unrecognized) manifestation of sarcoidosis in a variety of circumstances. Cardiac symptoms are usually dominant over extra-cardiac as most patients with clinically manifest disease have minimal extra-cardiac disease and up to two-thirds have isolated cardiac sarcoidosis (CS). It is estimated that another 20-25% of pulmonary/systemic sarcoidosis patients have asymptomatic cardiac involvement (clinically silent disease). The extent of left ventricular dysfunction seems to be the most important predictor of prognosis among patients with clinically manifest CS. In addition, the extent of myocardial late gadolinium enhancement is emerging as an important prognostic factor. The literature shows some controversy regarding outcomes for patients with clinically silent CS and larger studies are needed. Immunosuppression therapy (usually with corticosteroids) has been suggested for the treatment of clinically manifest CS despite minimal data supporting it. Fluorodeoxyglucose Positron Emission Tomography imaging is often used to detect active disease and guide immunosuppression. Patients with clinically manifest disease often need device therapy, typically with implantable cardioverter defibrillators. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  1. 4D motion modeling of the coronary arteries from CT images for robotic assisted minimally invasive surgery

    NASA Astrophysics Data System (ADS)

    Zhang, Dong Ping; Edwards, Eddie; Mei, Lin; Rueckert, Daniel

    2009-02-01

    In this paper, we present a novel approach for coronary artery motion modeling from cardiac Computed Tomography( CT) images. The aim of this work is to develop a 4D motion model of the coronaries for image guidance in robotic-assisted totally endoscopic coronary artery bypass (TECAB) surgery. To utilize the pre-operative cardiac images to guide the minimally invasive surgery, it is essential to have a 4D cardiac motion model to be registered with the stereo endoscopic images acquired intraoperatively using the da Vinci robotic system. In this paper, we are investigating the extraction of the coronary arteries and the modelling of their motion from a dynamic sequence of cardiac CT. We use a multi-scale vesselness filter to enhance vessels in the cardiac CT images. The centerlines of the arteries are extracted using a ridge traversal algorithm. Using this method the coronaries can be extracted in near real-time as only local information is used in vessel tracking. To compute the deformation of the coronaries due to cardiac motion, the motion is extracted from a dynamic sequence of cardiac CT. Each timeframe in this sequence is registered to the end-diastole timeframe of the sequence using a non-rigid registration algorithm based on free-form deformations. Once the images have been registered a dynamic motion model of the coronaries can be obtained by applying the computed free-form deformations to the extracted coronary arteries. To validate the accuracy of the motion model we compare the actual position of the coronaries in each time frame with the predicted position of the coronaries as estimated from the non-rigid registration. We expect that this motion model of coronaries can facilitate the planning of TECAB surgery, and through the registration with real-time endoscopic video images it can reduce the conversion rate from TECAB to conventional procedures.

  2. International Society for Heart and Lung Transplantation working formulation of a standardized nomenclature for cardiac allograft vasculopathy-2010.

    PubMed

    Mehra, Mandeep R; Crespo-Leiro, Maria G; Dipchand, Anne; Ensminger, Stephan M; Hiemann, Nicola E; Kobashigawa, Jon A; Madsen, Joren; Parameshwar, Jayan; Starling, Randall C; Uber, Patricia A

    2010-07-01

    The development of cardiac allograft vasculopathy remains the Achilles heel of cardiac transplantation. Unfortunately, the definitions of cardiac allograft vasculopathy are diverse, and there are no uniform international standards for the nomenclature of this entity. This consensus document, commissioned by the International Society of Heart and Lung Transplantation Board, is based on best evidence and clinical consensus derived from critical analysis of available information pertaining to angiography, intravascular ultrasound imaging, microvascular function, cardiac allograft histology, circulating immune markers, non-invasive imaging tests, and gene-based and protein-based biomarkers. This document represents a working formulation for an international nomenclature of cardiac allograft vasculopathy, similar to the development of the system for adjudication of cardiac allograft rejection by histology.

  3. Three-dimensional cardiac architecture determined by two-photon microtomy

    NASA Astrophysics Data System (ADS)

    Huang, Hayden; MacGillivray, Catherine; Kwon, Hyuk-Sang; Lammerding, Jan; Robbins, Jeffrey; Lee, Richard T.; So, Peter

    2009-07-01

    Cardiac architecture is inherently three-dimensional, yet most characterizations rely on two-dimensional histological slices or dissociated cells, which remove the native geometry of the heart. We previously developed a method for labeling intact heart sections without dissociation and imaging large volumes while preserving their three-dimensional structure. We further refine this method to permit quantitative analysis of imaged sections. After data acquisition, these sections are assembled using image-processing tools, and qualitative and quantitative information is extracted. By examining the reconstructed cardiac blocks, one can observe end-to-end adjacent cardiac myocytes (cardiac strands) changing cross-sectional geometries, merging and separating from other strands. Quantitatively, representative cross-sectional areas typically used for determining hypertrophy omit the three-dimensional component; we show that taking orientation into account can significantly alter the analysis. Using fast-Fourier transform analysis, we analyze the gross organization of cardiac strands in three dimensions. By characterizing cardiac structure in three dimensions, we are able to determine that the α crystallin mutation leads to hypertrophy with cross-sectional area increases, but not necessarily via changes in fiber orientation distribution.

  4. Advances in cardiac CT contrast injection and acquisition protocols.

    PubMed

    Scholtz, Jan-Erik; Ghoshhajra, Brian

    2017-10-01

    Cardiac computed tomography (CT) imaging has become an important part of modern cardiovascular care. Coronary CT angiography (CTA) is the first choice imaging modality for non-invasive visualization of coronary artery stenosis. In addition, cardiac CT does not only provide anatomical evaluation, but also functional and valvular assessment, and myocardial perfusion evaluation. In this article we outline the factors which influence contrast enhancement, give an overview of current contrast injection and acquisition protocols, with focus on current emerging topics such as pre-transcatheter aortic valve replacement (TAVR) planning, cardiac CT for congenital heart disease (CHD) patients, and myocardial CT perfusion (CTP). Further, we point out areas where we see potential for future improvements in cardiac CT imaging based on a closer interaction between CT scanner settings and contrast injection protocols to tailor injections to patient- and exam-specific factors.

  5. Advances in cardiac CT contrast injection and acquisition protocols

    PubMed Central

    Scholtz, Jan-Erik

    2017-01-01

    Cardiac computed tomography (CT) imaging has become an important part of modern cardiovascular care. Coronary CT angiography (CTA) is the first choice imaging modality for non-invasive visualization of coronary artery stenosis. In addition, cardiac CT does not only provide anatomical evaluation, but also functional and valvular assessment, and myocardial perfusion evaluation. In this article we outline the factors which influence contrast enhancement, give an overview of current contrast injection and acquisition protocols, with focus on current emerging topics such as pre-transcatheter aortic valve replacement (TAVR) planning, cardiac CT for congenital heart disease (CHD) patients, and myocardial CT perfusion (CTP). Further, we point out areas where we see potential for future improvements in cardiac CT imaging based on a closer interaction between CT scanner settings and contrast injection protocols to tailor injections to patient- and exam-specific factors. PMID:29255688

  6. Do Binucleate Cardiomyocytes Have A Role in Myocardial Repair? Insights Using Isolated Rodent Myocytes and Cell Culture

    PubMed Central

    Stephen, Michael J; Poindexter, Brian J; Moolman, Johan A; Sheikh-Hamad, David; Bick, Roger J

    2009-01-01

    Neonatal and adult cardiomyocytes were isolated from rat hearts. Some of the adult myocytes were cultured to allow for cell dedifferentiation, a phenomenon thought to mimic cell changes that occur in stressed myocardium, with myocytes regressing to a fetal pattern of metabolism and stellate neonatal shape. Using fluorescence deconvolution microscopy, cells were probed with fluorescent markers and scanned for a number of proteins associated with ion control, calcium movements and cardiac function. Image analysis of deconvoluted image stacks and sequential real-time image recordings of calcium transients of cells were made. All three myocyte groups were predominantly comprised of binucleate cells. Clustering of proteins to a single nucleus was a common observation, suggesting that one nucleus is active in protein synthesis pathways, while the other nucleus assumes a ‘dormant’ or different role and that cardiomyocytes might be mitotically active even in late development, or specific protein syntheses could be targeted and regulated for reintroduction into the cell cycle. Such possibilities would extend cardiac disease associated stem cell research and therapy options, while producing valuable insights into developmental and death pathways of binucleate cardiomyocytes (word count 183). PMID:19430572

  7. Integrated approach to ischemic heart disease. The one-stop shop.

    PubMed

    Kramer, C M

    1998-05-01

    Magnetic resonance imaging is unique in its variety of applications for imaging the cardiovascular system. A thorough assessment of myocardial structure, function, and perfusion; assessment of coronary artery anatomy and flow; and spectroscopic evaluation of cardiac energetics can be readily performed by magnetic resonance imaging. One key to the advancement of cardiac magnetic resonance imaging as a clinical tool in the evaluation, the so called one stop shop. Improvements in magnetic resonance hardware, software, and imaging speed now permit this integrated examination. Cardiac magnetic resonance is a powerful technique with the potential to replace or complement other commonly used techniques in the diagnostic armamentarium of physicians caring for patients with ischemic heart disease.

  8. Exercise training in Tgαq*44 mice during the progression of chronic heart failure: cardiac vs. peripheral (soleus muscle) impairments to oxidative metabolism.

    PubMed

    Grassi, Bruno; Majerczak, Joanna; Bardi, Eleonora; Buso, Alessia; Comelli, Marina; Chlopicki, Stefan; Guzik, Magdalena; Mavelli, Irene; Nieckarz, Zenon; Salvadego, Desy; Tyrankiewicz, Urszula; Skórka, Tomasz; Bottinelli, Roberto; Zoladz, Jerzy A; Pellegrino, Maria Antonietta

    2017-08-01

    Cardiac function, skeletal (soleus) muscle oxidative metabolism, and the effects of exercise training were evaluated in a transgenic murine model (Tgα q *44) of chronic heart failure during the critical period between the occurrence of an impairment of cardiac function and the stage at which overt cardiac failure ensues (i.e., from 10 to 12 mo of age). Forty-eight Tgα q *44 mice and 43 wild-type FVB controls were randomly assigned to control groups and to groups undergoing 2 mo of intense exercise training (spontaneous running on an instrumented wheel). In mice evaluated at the beginning and at the end of training we determined: exercise performance (mean distance covered daily on the wheel); cardiac function in vivo (by magnetic resonance imaging); soleus mitochondrial respiration ex vivo (by high-resolution respirometry); muscle phenotype [myosin heavy chain (MHC) isoform content; citrate synthase (CS) activity]; and variables related to the energy status of muscle fibers [ratio of phosphorylated 5'-AMP-activated protein kinase (AMPK) to unphosphorylated AMPK] and mitochondrial biogenesis and function [peroxisome proliferative-activated receptor-γ coactivator-α (PGC-1α)]. In the untrained Tgα q *44 mice functional impairments of exercise performance, cardiac function, and soleus muscle mitochondrial respiration were observed. The impairment of mitochondrial respiration was related to the function of complex I of the respiratory chain, and it was not associated with differences in CS activity, MHC isoforms, p-AMPK/AMPK, and PGC-1α levels. Exercise training improved exercise performance and cardiac function, but it did not affect mitochondrial respiration, even in the presence of an increased percentage of type 1 MHC isoforms. Factors "upstream" of mitochondria were likely mainly responsible for the improved exercise performance. NEW & NOTEWORTHY Functional impairments in exercise performance, cardiac function, and soleus muscle mitochondrial respiration were observed in transgenic chronic heart failure mice, evaluated in the critical period between the occurrence of an impairment of cardiac function and the terminal stage of the disease. Exercise training improved exercise performance and cardiac function, but it did not affect the impaired mitochondrial respiration. Factors "upstream" of mitochondria, including an enhanced cardiovascular O 2 delivery, were mainly responsible for the functional improvement. Copyright © 2017 the American Physiological Society.

  9. Assessment of mitral regurgitation in dogs: comparison of results of echocardiography with magnetic resonance imaging.

    PubMed

    Sargent, J; Connolly, D J; Watts, V; Mõtsküla, P; Volk, H A; Lamb, C R; Fuentes, V Luis

    2015-11-01

    Echocardiography is used routinely to assess mitral regurgitation severity, but echocardiographic measures of mitral regurgitation in dogs have not been compared with other quantitative methods. The study aim was to compare echocardiographic measures of mitral regurgitation with cardiac magnetic resonance imaging-derived mitral regurgitant fraction in small-breed dogs. Dogs with myxomatous mitral valve disease scheduled for magnetic resonance imaging assessment of neurological disease were recruited. Correlations were tested between cardiac magnetic resonance imaging-derived mitral regurgitant fraction and the following echocardiographic measures: vena contracta/aortic diameter, transmitral E-wave velocity, amplitude of mitral prolapse/aortic diameter, diastolic left ventricular diameter:aortic diameter, left atrium:aortic diameter, mitral regurgitation jet area ratio and regurgitant fraction calculated using the proximal isovelocity surface area method. Measurement of cardiac magnetic resonance imaging-derived mitral regurgitant fraction was attempted in 21 dogs. Twelve consecutive, complete studies were obtained and 10 dogs were included in the final analysis: vena contracta/aortic diameter (r = 0 · 89, p = 0 · 001) and E-wave velocity (r = 0 · 86, p = 0 · 001) had the strongest correlations with cardiac magnetic resonance imaging-derived mitral regurgitant fraction. E velocity had superior repeatability and could be measured in all dogs. The presence of multiple jets precluded vena contracta/aortic diameter measurement in one dog. Measurement of cardiac magnetic resonance imaging-derived mitral regurgitant fraction is feasible but technically demanding. The echocardiographic measures that correlated most closely with cardiac magnetic resonance imaging-derived mitral regurgitant fraction were vena contracta/aortic diameter and E-wave velocity. © 2015 British Small Animal Veterinary Association.

  10. A comparison study: image-based vs signal-based retrospective gating on microCT

    NASA Astrophysics Data System (ADS)

    Liu, Xuan; Salmon, Phil L.; Laperre, Kjell; Sasov, Alexander

    2017-09-01

    Retrospective gating on animal studies with microCT has gained popularity in recent years. Previously, we use ECG signals for cardiac gating and breathing airflow or video signals of abdominal motion for respiratory gating. This method is adequate and works well for most applications. However, through the years, researchers have noticed some pitfalls in the method. For example, the additional signal acquisition step may increase failure rate in practice. X-Ray image-based gating, on the other hand, does not require any extra step in the scanning. Therefore we investigate imagebased gating techniques. This paper presents a comparison study of the image-based versus signal-based approach to retrospective gating. The two application areas we have studied are respiratory and cardiac imaging for both rats and mice. Image-based respiratory gating on microCT is relatively straightforward and has been done by several other researchers and groups. This method retrieves an intensity curve of a region of interest (ROI) placed in the lung area on all projections. From scans on our systems based on step-and-shoot scanning mode, we confirm that this method is very effective. A detailed comparison between image-based and signal-based gating methods is given. For cardiac gating, breathing motion is not negligible and has to be dealt with. Another difficulty in cardiac gating is the relatively smaller amplitude of cardiac movements comparing to the respirational movements, and the higher heart rate. Higher heart rate requires high speed image acquisition. We have been working on our systems to improve the acquisition speed. A dual gating technique has been developed to achieve adequate cardiac imaging.

  11. Multimodality Imaging in Cardiac Sarcoidosis: Is There a Winner?

    PubMed Central

    Perez, Irving E.; Garcia, Mario J.; Taub, Cynthia C.

    2016-01-01

    Sarcoidosis is a multisystem granulomatous disease of unknown cause that can affect the heart. Cardiac sarcoidosis may be present in as many as 25% of patients with systemic sarcoidosis, and it is frequently underdiagnosed. The early and accurate diagnosis of myocardial involvement is challenging. Advanced imaging techniques play important roles in the diagnosis and management of patients with cardiac sarcoidosis. PMID:25784137

  12. Cardiac Radionuclide Imaging in Rodents: A Review of Methods, Results, and Factors at Play

    PubMed Central

    Cicone, Francesco; Viertl, David; Quintela Pousa, Ana Maria; Denoël, Thibaut; Gnesin, Silvano; Scopinaro, Francesco; Vozenin, Marie-Catherine; Prior, John O.

    2017-01-01

    The interest around small-animal cardiac radionuclide imaging is growing as rodent models can be manipulated to allow the simulation of human diseases. In addition to new radiopharmaceuticals testing, often researchers apply well-established probes to animal models, to follow the evolution of the target disease. This reverse translation of standard radiopharmaceuticals to rodent models is complicated by technical shortcomings and by obvious differences between human and rodent cardiac physiology. In addition, radionuclide studies involving small animals are affected by several extrinsic variables, such as the choice of anesthetic. In this paper, we review the major cardiac features that can be studied with classical single-photon and positron-emitting radiopharmaceuticals, namely, cardiac function, perfusion and metabolism, as well as the results and pitfalls of small-animal radionuclide imaging techniques. In addition, we provide a concise guide to the understanding of the most frequently used anesthetics such as ketamine/xylazine, isoflurane, and pentobarbital. We address in particular their mechanisms of action and the potential effects on radionuclide imaging. Indeed, cardiac function, perfusion, and metabolism can all be significantly affected by varying anesthetics and animal handling conditions. PMID:28424774

  13. Relationship between cardiac quiescent periods derived from seismocardiography and echocardiography.

    PubMed

    Wick, Carson A; Inan, Omer T; Bhatti, Pamela; Tridandapani, Srini

    2015-08-01

    The seismocardiogram (SCG) is a measure of chest wall acceleration due to cardiac motion that could potentially supplement the electrocardiogram (ECG) to more reliably predict cardiac quiescence. Accurate prediction is critical for modalities requiring minimal motion during imaging data acquisition, such as cardiac computed tomography (CT) and magnetic resonance imaging (MRI). For seven healthy subjects, SCG and B-mode echocardiography were used to identify quiescent periods on a beat-by-beat basis. Quiescent periods were detected as time intervals when the magnitude of the velocity signals calculated from SCG and echocardiography were less than a specified threshold. The quiescent periods detected from SCG were compared to those detected from B-mode echocardiography. The quiescent periods of the SCG were found to occur before those detected by echocardiography. A linear relationship between the delay from SCG- to echocardiography-detected phases with respect to heart rate was found. This delay could potentially be used to predict cardiac quiescence from SCG-observed quiescence for use with cardiac imaging modalities such as CT and MRI.

  14. Myocarditis in Patients With Antisynthetase Syndrome: Prevalence, Presentation, and Outcomes.

    PubMed

    Dieval, Céline; Deligny, Christophe; Meyer, Alain; Cluzel, Philippe; Champtiaux, Nicolas; Lefevre, Guillaume; Saadoun, David; Sibilia, Jean; Pellegrin, Jean-Luc; Hachulla, Eric; Benveniste, Olivier; Hervier, Baptiste

    2015-07-01

    Antisynthetase syndrome (aSS) corresponds to an overlapping inflammatory myopathy identified by various myositis-specific autoantibodies (directed against tRNA-synthetases). Myocardial involvement in this condition is poorly described.From a registry of 352 aSS patients, 12 cases of myocarditis were retrospectively identified on the basis of an unexplained increase in troponin T/I levels associated with either suggestive cardiac magnetic resonance imaging (MRI) findings, nonsignificant coronary artery abnormalities or positive endomyocardial biopsy.The prevalence of myocarditis in aSS is 3.4% and was not linked to any autoantibody specificity: anti-Jo1 (n = 8), anti-PL7 (n = 3), and anti-PL12 (n = 1). Myocarditis was a part of the first aSS manifestations in 42% of the cases and was asymptomatic (n = 2) or revealed by an acute (n = 4) or a subacute (n = 6) cardiac failure. It should be noted that myocarditis was always associated with an active myositis. When performed (n = 11), cardiac MRI revealed a late hypersignal in the T1-images in 73% of the cases (n = 8). Half of the patients required intensive care. Ten patients (83%) received dedicated cardiotropic drugs. Steroids and at least 1 immunosuppressive drug were given in all cases. After a median follow-up of 11 months (range 0-84) 9 (75%) patients recovered whereas 3 (25%) developed a chronic cardiac insufficiency. No patient died.The prevalence of myocarditis in aSS is similar to that of other inflammatory myopathies. Although the prognosis is relatively good, myocarditis is a severe condition and should be carefully considered as a possible manifestation in active aSS patients.

  15. Effect of hydration status on atrial and ventricular volumes and function in healthy adult volunteers.

    PubMed

    Schantz, Daryl I; Dragulescu, Andreea; Memauri, Brett; Grotenhuis, Heynric B; Seed, Mike; Grosse-Wortmann, Lars

    2016-10-01

    Assessment of cardiac chamber volumes is a fundamental part of cardiac magnetic resonance (CMR) imaging. While the effects of inter- and intraobserver variability have been studied and have a recognized effect on the comparability of serial cardiac MR imaging studies, the effect of differences in hydration status has not been evaluated. To evaluate the effects of volume administration on cardiac chamber volumes. Thirteen healthy adults underwent a baseline cardiac MR to evaluate cardiac chamber volumes after an overnight fast. They were then given two saline boluses of 10 ml/kg of body weight and the cardiac MR was repeated immediately after each bolus. From the baseline scan to the final scan there was a significant increase in all four cardiac chamber end-diastolic volumes. Right atrial volumes increased 8.0%, from 61.1 to 66.0 ml/m2 (P<0.001), and left atrial volumes increased 10.0%, from 50.0 to 55.0 ml/m2 (P<0.001). Right ventricular volumes increased 6.0%, from 91.1 to 96.5 ml/m2 (P<0.001), and left ventricular volumes increased 3.2%, from 87.0 to 89.8 ml/m2 (P<0.001). Hydration status has a significant effect on the end-diastolic volumes of all cardiac chambers assessed by cardiac MR. Thus, hydration represents a "variable" that should be taken into account when assessing cardiac chamber volumes, especially when performing serial imaging studies in a patient.

  16. First experience of simultaneous PET/MRI for the early detection of cardiac involvement in patients with Anderson-Fabry disease.

    PubMed

    Nappi, Carmela; Altiero, Michele; Imbriaco, Massimo; Nicolai, Emanuele; Giudice, Caterina Anna; Aiello, Marco; Diomiaiuti, Claudio Tommaso; Pisani, Antonio; Spinelli, Letizia; Cuocolo, Alberto

    2015-06-01

    Anderson-Fabry disease (AFD) is an X-linked lysosomal storage disorder associated with severe multiorgan dysfunction and premature death. Early diagnosis and treatment strategies play a key role in patient outcome. We investigated the potential role of hybrid PET/MR imaging in the assessment of early cardiac involvement in AFD patients. Thirteen AFD patients without cardiac symptoms and with normal left ventricular function underwent simultaneous cardiac PET/MR imaging after administration of (18)F-FDG. Cardiac FDG uptake was quantified by measuring the standardized uptake value in 17 myocardial segments in each subject. The coefficient of variation (COV, i.e. the standard deviation divided by the average) of the uptake of the 17 segments was calculated as an index of heterogeneity in the heart. Six patients exhibited focal late gadolinium enhancement (LGE) indicating intramyocardial fibrosis, and four of these also had positive short inversion time inversion recovery (STIR) sequences. All patients with LGE and positive STIR MR images showed focal FDG uptake in the corresponding myocardial segments indicating inflammation. Of the seven patients with negative LGE and STIR images, five showed homogeneous FDG cardiac uptake and two showed heterogeneous FDG uptake. The COV was significantly greater in patients with focal FDG uptake (0.25 ± 0.02) than in those without (0.14 ± 0.07, p < 0.01). PET/MR imaging is clinically feasible for the early detection of cardiac involvement in patients with AFD. Further studies evaluating the role of hybrid PET/MR imaging in management of the disease in larger patient populations are warranted.

  17. Transmural Ultrasound-based Visualization of Patterns of Action Potential Wave Propagation in Cardiac Tissue

    PubMed Central

    Luther, Stefan; Singh, Rupinder; Gilmour, Robert F.

    2010-01-01

    The pattern of action potential propagation during various tachyarrhythmias is strongly suspected to be composed of multiple re-entrant waves, but has never been imaged in detail deep within myocardial tissue. An understanding of the nature and dynamics of these waves is important in the development of appropriate electrical or pharmacological treatments for these pathological conditions. We propose a new imaging modality that uses ultrasound to visualize the patterns of propagation of these waves through the mechanical deformations they induce. The new method would have the distinct advantage of being able to visualize these waves deep within cardiac tissue. In this article, we describe one step that would be necessary in this imaging process—the conversion of these deformations into the action potential induced active stresses that produced them. We demonstrate that, because the active stress induced by an action potential is, to a good approximation, only nonzero along the local fiber direction, the problem in our case is actually overdetermined, allowing us to obtain a complete solution. Use of two- rather than three-dimensional displacement data, noise in these displacements, and/or errors in the measurements of the fiber orientations all produce substantial but acceptable errors in the solution. We conclude that the reconstruction of action potential-induced active stress from the deformation it causes appears possible, and that, therefore, the path is open to the development of the new imaging modality. PMID:20499183

  18. High-frequency ultrasound M-mode monitoring of HIFU ablation in cardiac tissue

    NASA Astrophysics Data System (ADS)

    Kumon, R. E.; Gudur, M. S. R.; Zhou, Y.; Deng, C. X.

    2012-10-01

    Effective real-time HIFU lesion detection is important for expanded use of HIFU in interventional electrophysiology (e.g., epicardial ablation of cardiac arrhythmia). The goal of this study was to investigate rapid, high-frequency M-mode ultrasound imaging for monitoring spatiotemporal changes in tissue during HIFU application. The HIFU application (4.33 MHz, 1000 Hz PRF, 50% duty cycle, 1 s exposure, 6100 W/cm2) was perpendicularly applied to porcine cardiac tissue with a high-frequency imaging system (Visualsonics Vevo 770, 55 MHz, 4.5 mm focal distance) confocally aligned. Radiofrequency (RF) M-mode data (1 kHz PRF, 4 s × 7 mm) was acquired before, during, and after HIFU treatment. Gross lesions were compared with M-mode data to correlate lesion and cavity formation. Integrated backscatter, echo-decorrelation parameters, and their cumulative extrema over time were analyzed for automatically identifying lesion width and bubble formation. Cumulative maximum integrated backscatter showed the best results for identifying the final lesion width, and a criterion based on line-to-line decorrelation was proposed for identification of transient bubble activity.

  19. The effects of center of rotation errors on cardiac SPECT imaging

    NASA Astrophysics Data System (ADS)

    Bai, Chuanyong; Shao, Ling; Ye, Jinghan; Durbin, M.

    2003-10-01

    In SPECT imaging, center of rotation (COR) errors lead to the misalignment of projection data and can potentially degrade the quality of the reconstructed images. In this work, we study the effects of COR errors on cardiac SPECT imaging using simulation, point source, cardiac phantom, and patient studies. For simulation studies, we generate projection data using a uniform MCAT phantom first without modeling any physical effects (NPH), then with the modeling of detector response effect (DR) alone. We then corrupt the projection data with simulated sinusoid and step COR errors. For other studies, we introduce sinusoid COR errors to projection data acquired on SPECT systems. An OSEM algorithm is used for image reconstruction without detector response correction, but with nonuniform attenuation correction when needed. The simulation studies show that, when COR errors increase from 0 to 0.96 cm: 1) sinusoid COR errors in axial direction lead to intensity decrease in the inferoapical region; 2) step COR errors in axial direction lead to intensity decrease in the distal anterior region. The intensity decrease is more severe in images reconstructed from projection data with NPH than with DR; and 3) the effects of COR errors in transaxial direction seem to be insignificant. In other studies, COR errors slightly degrade point source resolution; COR errors of 0.64 cm or above introduce visible but insignificant nonuniformity in the images of uniform cardiac phantom; COR errors up to 0.96 cm in transaxial direction affect the lesion-to-background contrast (LBC) insignificantly in the images of cardiac phantom with defects, and COR errors up to 0.64 cm in axial direction only slightly decrease the LBC. For the patient studies with COR errors up to 0.96 cm, images have the same diagnostic/prognostic values as those without COR errors. This work suggests that COR errors of up to 0.64 cm are not likely to change the clinical applications of cardiac SPECT imaging when using iterative reconstruction algorithm without detector response correction.

  20. Joint multi-object registration and segmentation of left and right cardiac ventricles in 4D cine MRI

    NASA Astrophysics Data System (ADS)

    Ehrhardt, Jan; Kepp, Timo; Schmidt-Richberg, Alexander; Handels, Heinz

    2014-03-01

    The diagnosis of cardiac function based on cine MRI requires the segmentation of cardiac structures in the images, but the problem of automatic cardiac segmentation is still open, due to the imaging characteristics of cardiac MR images and the anatomical variability of the heart. In this paper, we present a variational framework for joint segmentation and registration of multiple structures of the heart. To enable the simultaneous segmentation and registration of multiple objects, a shape prior term is introduced into a region competition approach for multi-object level set segmentation. The proposed algorithm is applied for simultaneous segmentation of the myocardium as well as the left and right ventricular blood pool in short axis cine MRI images. Two experiments are performed: first, intra-patient 4D segmentation with a given initial segmentation for one time-point in a 4D sequence, and second, a multi-atlas segmentation strategy is applied to unseen patient data. Evaluation of segmentation accuracy is done by overlap coefficients and surface distances. An evaluation based on clinical 4D cine MRI images of 25 patients shows the benefit of the combined approach compared to sole registration and sole segmentation.

  1. Carbon Tube Electrodes for Electrocardiography-Gated Cardiac Multimodality Imaging in Mice

    PubMed Central

    Choquet, Philippe; Goetz, Christian; Aubertin, Gaelle; Hubele, Fabrice; Sannié, Sébastien; Constantinesco, André

    2011-01-01

    This report describes a simple design of noninvasive carbon tube electrodes that facilitates electrocardiography (ECG) in mice during cardiac multimodality preclinical imaging. Both forepaws and the left hindpaw, covered by conductive gel, of mice were placed into the openings of small carbon tubes. Cardiac ECG-gated single-photon emission CT, X-ray CT, and MRI were tested (n = 60) in 20 mice. For all applications, electrodes were used in a warmed multimodality imaging cell. A heart rate of 563 ± 48 bpm was recorded from anesthetized mice regardless of the imaging technique used, with acquisition times ranging from 1 to 2 h. PMID:21333165

  2. Contactless magnetocardiographic mapping in anesthetized Wistar rats: evidence of age-related changes of cardiac electrical activity.

    PubMed

    Brisinda, Donatella; Caristo, Maria Emiliana; Fenici, Riccardo

    2006-07-01

    Magnetocardiography (MCG) is the recording of the magnetic field (MF) generated by cardiac electrophysiological activity. Because it is a contactless method, MCG is ideal for noninvasive cardiac mapping of small experimental animals. The aim of this study was to assess age-related changes of cardiac intervals and ventricular repolarization (VR) maps in intact rats by means of MCG mapping. Twenty-four adult Wistar rats (12 male and 12 female) were studied, under anesthesia, with the same unshielded 36-channel MCG instrumentation used for clinical recordings. Two sets of measurements were obtained from each animal: 1) at 5 mo of age (297.5 +/- 21 g body wt) and 2) at 14 mo of age (516.8 +/- 180 g body wt). RR and PR intervals, QRS segment, and QTpeak, QTend, JTpeak, JTend, and Tpeak-end were measured from MCG waveforms. MCG imaging was automatically obtained as MF maps and as inverse localization of cardiac sources with equivalent current dipole and effective magnetic dipole models. After 300 s of continuous recording were averaged, the signal-to-noise ratio was adequate for study of atrial and ventricular MF maps and for three-dimensional localization of the underlying cardiac sources. Clear-cut age-related differences in VR duration were demonstrated by significantly longer QTend, JTend, and Tpeak-end in older Wistar rats. Reproducible multisite noninvasive cardiac mapping of anesthetized rats is simpler with MCG methodology than with ECG recording. In addition, MCG mapping provides new information based on quantitative analysis of MF and equivalent sources. In this study, statistically significant age-dependent variations in VR intervals were found.

  3. Robust boundary detection of left ventricles on ultrasound images using ASM-level set method.

    PubMed

    Zhang, Yaonan; Gao, Yuan; Li, Hong; Teng, Yueyang; Kang, Yan

    2015-01-01

    Level set method has been widely used in medical image analysis, but it has difficulties when being used in the segmentation of left ventricular (LV) boundaries on echocardiography images because the boundaries are not very distinguish, and the signal-to-noise ratio of echocardiography images is not very high. In this paper, we introduce the Active Shape Model (ASM) into the traditional level set method to enforce shape constraints. It improves the accuracy of boundary detection and makes the evolution more efficient. The experiments conducted on the real cardiac ultrasound image sequences show a positive and promising result.

  4. Evaluation of athletes with complex congenital heart disease.

    PubMed

    Bates, Benjamin A; Richards, Camille; Hall, Michael; Kerut, Edmund K; Campbell, William; McMullan, Michael R

    2017-06-01

    As a result of improvements in congenital heart surgery, there are more adults alive today with congenital heart disease (CHD) than children. Individuals with cardiac birth defects may be able to participate in physical activities but require proper cardiovascular evaluation. The American Heart Association and American College of Cardiology released guidelines in 2015 for athletes with cardiovascular abnormalities. The guidelines express that although restriction from competitive athletics may be indicated for some, the majority of individuals with CHD can and should engage in some form of physical activity. This case study demonstrates the importance of combining all aspects of history, physical examination, ECG, and imaging modalities to evaluate cardiac anatomy and function in young athletes with complex CHD. © 2017, Wiley Periodicals, Inc.

  5. Emerging Cardiac Imaging Modalities for the Early Detection of Cardiotoxicity Due to Anticancer Therapies.

    PubMed

    López-Fernández, Teresa; Thavendiranathan, Paaladinesh

    2017-06-01

    The undeniable advances in the field of oncology have finally led to a decrease in overall cancer-related mortality. However, this population of long-term cancer survivors is now facing a shift toward a substantial increase in cardiovascular morbidity and mortality. Because the development of overt cardiotoxicity can be associated with poor outcomes, preclinical identification of cardiac toxicity is important. This will promote early instauration of treatments to prevent overt heart dysfunction and allow oncologists to continue cancer therapy in an uninterrupted manner. Surveillance strategies for the early detection of cardiac injury include cardiac imaging and biomarkers during treatment. In this review, we outline existing cardiac imaging modalities to detect myocardial changes in patients undergoing cancer treatment and in survivors, and their strengths and limitations. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  6. ASCI 2010 appropriateness criteria for cardiac computed tomography: a report of the Asian Society of Cardiovascular Imaging Cardiac Computed Tomography and Cardiac Magnetic Resonance Imaging Guideline Working Group.

    PubMed

    Tsai, I-Chen; Choi, Byoung Wook; Chan, Carmen; Jinzaki, Masahiro; Kitagawa, Kakuya; Yong, Hwan Seok; Yu, Wei

    2010-02-01

    In Asia, the healthcare system, populations and patterns of disease differ from Western countries. The current reports on the criteria for cardiac CT scans, provided by Western professional societies, are not appropriate for Asian cultures. The Asian Society of Cardiovascular Imaging, the only society dedicated to cardiovascular imaging in Asia, formed a Working Group and invited 23 Technical Panel members representing a variety of Asian countries to rate the 51 indications for cardiac CT in clinical practice in Asia. The indications were rated as 'appropriate' (7-9), 'uncertain' (4-6), or 'inappropriate' (1-3) on a scale of 1-9. The median score was used for the final result if there was no disagreement. The final ratings for indications were 33 appropriate, 14 uncertain and 4 inappropriate. And 20 of them are highly agreed (19 appropriate and 1 inappropriate). Specifically, the Asian representatives considered cardiac CT as an appropriate modality for Kawasaki disease and congenital heart diseases in follow up and in symptomatic patients. In addition, except for some specified conditions, cardiac CT was considered to be an appropriate modality for one-stop shop ischemic heart disease evaluation due to its general appropriateness in coronary, structure and function evaluation. This report is expected to have a significant impact on the clinical practice, research and reimbursement policy in Asia.

  7. A method to quantify mechanobiologic forces during zebrafish cardiac development using 4-D light sheet imaging and computational modeling

    PubMed Central

    Vedula, Vijay; Lee, Juhyun; Xu, Hao; Hsiai, Tzung K.

    2017-01-01

    Blood flow and mechanical forces in the ventricle are implicated in cardiac development and trabeculation. However, the mechanisms of mechanotransduction remain elusive. This is due in part to the challenges associated with accurately quantifying mechanical forces in the developing heart. We present a novel computational framework to simulate cardiac hemodynamics in developing zebrafish embryos by coupling 4-D light sheet imaging with a stabilized finite element flow solver, and extract time-dependent mechanical stimuli data. We employ deformable image registration methods to segment the motion of the ventricle from high resolution 4-D light sheet image data. This results in a robust and efficient workflow, as segmentation need only be performed at one cardiac phase, while wall position in the other cardiac phases is found by image registration. Ventricular hemodynamics are then quantified by numerically solving the Navier-Stokes equations in the moving wall domain with our validated flow solver. We demonstrate the applicability of the workflow in wild type zebrafish and three treated fish types that disrupt trabeculation: (a) chemical treatment using AG1478, an ErbB2 signaling inhibitor that inhibits proliferation and differentiation of cardiac trabeculation; (b) injection of gata1a morpholino oligomer (gata1aMO) suppressing hematopoiesis and resulting in attenuated trabeculation; (c) weak-atriumm58 mutant (wea) with inhibited atrial contraction leading to a highly undeveloped ventricle and poor cardiac function. Our simulations reveal elevated wall shear stress (WSS) in wild type and AG1478 compared to gata1aMO and wea. High oscillatory shear index (OSI) in the grooves between trabeculae, compared to lower values on the ridges, in the wild type suggest oscillatory forces as a possible regulatory mechanism of cardiac trabeculation development. The framework has broad applicability for future cardiac developmental studies focused on quantitatively investigating the role of hemodynamic forces and mechanotransduction during morphogenesis. PMID:29084212

  8. Comparison of the Extended Kalman Filter and the Unscented Kalman Filter for Magnetocardiography activation time imaging

    NASA Astrophysics Data System (ADS)

    Ahrens, H.; Argin, F.; Klinkenbusch, L.

    2013-07-01

    The non-invasive and radiation-free imaging of the electrical activity of the heart with Electrocardiography (ECG) or Magnetocardiography (MCG) can be helpful for physicians for instance in the localization of the origin of cardiac arrhythmia. In this paper we compare two Kalman Filter algorithms for the solution of a nonlinear state-space model and for the subsequent imaging of the activation/depolarization times of the heart muscle: the Extended Kalman Filter (EKF) and the Unscented Kalman Filter (UKF). The algorithms are compared for simulations of a (6×6) magnetometer array, a torso model with piecewise homogeneous conductivities, 946 current dipoles located in a small part of the heart (apex), and several noise levels. It is found that for all tested noise levels the convergence of the activation times is faster for the UKF.

  9. On the Design of an Efficient Cardiac Health Monitoring System Through Combined Analysis of ECG and SCG Signals.

    PubMed

    Sahoo, Prasan Kumar; Thakkar, Hiren Kumar; Lin, Wen-Yen; Chang, Po-Cheng; Lee, Ming-Yih

    2018-01-28

    Cardiovascular disease (CVD) is a major public concern and socioeconomic problem across the globe. The popular high-end cardiac health monitoring systems such as magnetic resonance imaging (MRI), computerized tomography scan (CT scan), and echocardiography (Echo) are highly expensive and do not support long-term continuous monitoring of patients without disrupting their activities of daily living (ADL). In this paper, the continuous and non-invasive cardiac health monitoring using unobtrusive sensors is explored aiming to provide a feasible and low-cost alternative to foresee possible cardiac anomalies in an early stage. It is learned that cardiac health monitoring based on sole usage of electrocardiogram (ECG) signals may not provide powerful insights as ECG provides shallow information on various cardiac activities in the form of electrical impulses only. Hence, a novel low-cost, non-invasive seismocardiogram (SCG) signal along with ECG signals are jointly investigated for the robust cardiac health monitoring. For this purpose, the in-laboratory data collection model is designed for simultaneous acquisition of ECG and SCG signals followed by mechanisms for the automatic delineation of relevant feature points in acquired ECG and SCG signals. In addition, separate feature points based novel approach is adopted to distinguish between normal and abnormal morphology in each ECG and SCG cardiac cycle. Finally, a combined analysis of ECG and SCG is carried out by designing a Naïve Bayes conditional probability model. Experiments on Institutional Review Board (IRB) approved licensed ECG/SCG signals acquired from real subjects containing 12,000 cardiac cycles show that the proposed feature point delineation mechanisms and abnormal morphology detection methods consistently perform well and give promising results. In addition, experimental results show that the combined analysis of ECG and SCG signals provide more reliable cardiac health monitoring compared to the standalone use of ECG and SCG.

  10. On the Design of an Efficient Cardiac Health Monitoring System Through Combined Analysis of ECG and SCG Signals

    PubMed Central

    Lin, Wen-Yen; Chang, Po-Cheng

    2018-01-01

    Cardiovascular disease (CVD) is a major public concern and socioeconomic problem across the globe. The popular high-end cardiac health monitoring systems such as magnetic resonance imaging (MRI), computerized tomography scan (CT scan), and echocardiography (Echo) are highly expensive and do not support long-term continuous monitoring of patients without disrupting their activities of daily living (ADL). In this paper, the continuous and non-invasive cardiac health monitoring using unobtrusive sensors is explored aiming to provide a feasible and low-cost alternative to foresee possible cardiac anomalies in an early stage. It is learned that cardiac health monitoring based on sole usage of electrocardiogram (ECG) signals may not provide powerful insights as ECG provides shallow information on various cardiac activities in the form of electrical impulses only. Hence, a novel low-cost, non-invasive seismocardiogram (SCG) signal along with ECG signals are jointly investigated for the robust cardiac health monitoring. For this purpose, the in-laboratory data collection model is designed for simultaneous acquisition of ECG and SCG signals followed by mechanisms for the automatic delineation of relevant feature points in acquired ECG and SCG signals. In addition, separate feature points based novel approach is adopted to distinguish between normal and abnormal morphology in each ECG and SCG cardiac cycle. Finally, a combined analysis of ECG and SCG is carried out by designing a Naïve Bayes conditional probability model. Experiments on Institutional Review Board (IRB) approved licensed ECG/SCG signals acquired from real subjects containing 12,000 cardiac cycles show that the proposed feature point delineation mechanisms and abnormal morphology detection methods consistently perform well and give promising results. In addition, experimental results show that the combined analysis of ECG and SCG signals provide more reliable cardiac health monitoring compared to the standalone use of ECG and SCG. PMID:29382098

  11. The Cardiac Atlas Project--an imaging database for computational modeling and statistical atlases of the heart.

    PubMed

    Fonseca, Carissa G; Backhaus, Michael; Bluemke, David A; Britten, Randall D; Chung, Jae Do; Cowan, Brett R; Dinov, Ivo D; Finn, J Paul; Hunter, Peter J; Kadish, Alan H; Lee, Daniel C; Lima, Joao A C; Medrano-Gracia, Pau; Shivkumar, Kalyanam; Suinesiaputra, Avan; Tao, Wenchao; Young, Alistair A

    2011-08-15

    Integrative mathematical and statistical models of cardiac anatomy and physiology can play a vital role in understanding cardiac disease phenotype and planning therapeutic strategies. However, the accuracy and predictive power of such models is dependent upon the breadth and depth of noninvasive imaging datasets. The Cardiac Atlas Project (CAP) has established a large-scale database of cardiac imaging examinations and associated clinical data in order to develop a shareable, web-accessible, structural and functional atlas of the normal and pathological heart for clinical, research and educational purposes. A goal of CAP is to facilitate collaborative statistical analysis of regional heart shape and wall motion and characterize cardiac function among and within population groups. Three main open-source software components were developed: (i) a database with web-interface; (ii) a modeling client for 3D + time visualization and parametric description of shape and motion; and (iii) open data formats for semantic characterization of models and annotations. The database was implemented using a three-tier architecture utilizing MySQL, JBoss and Dcm4chee, in compliance with the DICOM standard to provide compatibility with existing clinical networks and devices. Parts of Dcm4chee were extended to access image specific attributes as search parameters. To date, approximately 3000 de-identified cardiac imaging examinations are available in the database. All software components developed by the CAP are open source and are freely available under the Mozilla Public License Version 1.1 (http://www.mozilla.org/MPL/MPL-1.1.txt). http://www.cardiacatlas.org a.young@auckland.ac.nz Supplementary data are available at Bioinformatics online.

  12. Identification and Assessment of Cardiac Amyloidosis by Myocardial Strain Analysis of Cardiac Magnetic Resonance Imaging.

    PubMed

    Oda, Seitaro; Utsunomiya, Daisuke; Nakaura, Takeshi; Yuki, Hideaki; Kidoh, Masafumi; Morita, Kosuke; Takashio, Seiji; Yamamuro, Megumi; Izumiya, Yasuhiro; Hirakawa, Kyoko; Ishida, Toshifumi; Tsujita, Kenichi; Ueda, Mitsuharu; Yamashita, Taro; Ando, Yukio; Hata, Hiroyuki; Yamashita, Yasuyuki

    2017-06-23

    We explored the usefulness of myocardial strain analysis on cardiac magnetic resonance imaging (CMR) scans for the identification of cardiac amyloidosis.Methods and Results:The 61 patients with systemic amyloidosis underwent 3.0-T CMR, including CMR tagging and late-gadolinium enhanced (LGE) imaging. The circumferential strain (CS) of LGE-positive and LGE-negative patients was measured on midventricular short-axis images and compared. Logistic regression modeling of CMR parameters was performed to detect patients with LGE-positive cardiac amyloidosis. Of the 61 patients with systemic amyloidosis 48 were LGE-positive and 13 were LGE-negative. The peak CS was significantly lower in the LGE-positive than in the LGE-negative patients (-9.5±2.3 vs. -13.3±1.4%, P<0.01). The variability in the peak CS time was significantly greater in the LGE-positive than in the LGE-negative patients (46.1±24.5 vs. 21.2±20.1 ms, P<0.01). The peak CS significantly correlated with clinical biomarkers. The sensitivity, specificity, and accuracy of the diagnostic model using CS parameters for the identification of LGE-positive amyloidosis were 93.8%, 76.9%, and 90.2%, respectively. Myocardial strain analysis by CMR helped detect LGE-positive amyloidosis without the need for contrast medium. The peak CS and variability in the peak CS time may correlate with the severity of cardiac amyloid deposition and may be more sensitive than LGE imaging for the detection of early cardiac disease in patients with amyloidosis.

  13. Quantitative cardiac SPECT reconstruction with reduced image degradation due to patient anatomy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsui, B.M.W.; Zhao, X.D.; Gregoriou, G.K.

    1994-12-01

    Patient anatomy has complicated effects on cardiac SPECT images. The authors investigated reconstruction methods which substantially reduced these effects for improved image quality. A 3D mathematical cardiac-torso (MCAT) phantom which models the anatomical structures in the thorax region were used in the study. The phantom was modified to simulate variations in patient anatomy including regions of natural thinning along the myocardium, body size, diaphragmatic shape, gender, and size and shape of breasts for female patients. Distributions of attenuation coefficients and Tl-201 uptake in different organs in a normal patient were also simulated. Emission projection data were generated from the phantomsmore » including effects of attenuation and detector response. The authors have observed the attenuation-induced artifacts caused by patient anatomy in the conventional FBP reconstructed images. Accurate attenuation compensation using iterative reconstruction algorithms and attenuation maps substantially reduced the image artifacts and improved quantitative accuracy. They conclude that reconstruction methods which accurately compensate for non-uniform attenuation can substantially reduce image degradation caused by variations in patient anatomy in cardiac SPECT.« less

  14. Image reconstruction in higher dimensions: myocardial perfusion imaging of tracer dynamics with cardiac motion due to deformation and respiration

    DOE PAGES

    Shrestha, Uttam M.; Seo, Youngho; Botvinick, Elias H.; ...

    2015-10-09

    Myocardial perfusion imaging (MPI) using slow rotating large field of view cameras requires spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration. In vivo, MPI contains additional degrees of freedom involving unavoidable motion of the heart due to quasiperiodic beating and the effects of respiration, which can severely degrade the quality of the images. This work develops a technique for a single photon emission computed tomography (SPECT) that reconstructs the distribution of the radiotracer concentration in the myocardium using a tensor product of different sets of basis functions that approximately describe the spatiotemporal variationmore » of the radiotracer concentration and the motion of the heart. In this study the temporal B-spline basis functions are chosen to reflect the dynamics of the radiotracer, while the intrinsic deformation and the extrinsic motion of the heart are described by a product of a discrete set of Gaussian basis functions. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it deforms due to cardiac beating, and is displaced due to respiratory motion. We find these results are compared with the conventional 4D-spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. The higher dimensional reconstruction method proposed here improves bias, yet the signal-to-noise ratio (SNR) decreases slightly due to redistribution of the counts over the cardiac-respiratory gates. Finally, there is a trade-off between the number of gates and the number of projections per gate to achieve high contrast images.« less

  15. Therapeutic hypothermia after cardiac arrest: outcome predictors

    PubMed Central

    Leão, Rodrigo Nazário; Ávila, Paulo; Cavaco, Raquel; Germano, Nuno; Bento, Luís

    2015-01-01

    Objective The determination of coma patient prognosis after cardiac arrest has clinical, ethical and social implications. Neurological examination, imaging and biochemical markers are helpful tools accepted as reliable in predicting recovery. With the advent of therapeutic hypothermia, these data need to be reconfirmed. In this study, we attempted to determine the validity of different markers, which can be used in the detection of patients with poor prognosis under hypothermia. Methods Data from adult patients admitted to our intensive care unit for a hypothermia protocol after cardiac arrest were recorded prospectively to generate a descriptive and analytical study analyzing the relationship between clinical, neurophysiological, imaging and biochemical parameters with 6-month outcomes defined according to the Cerebral Performance Categories scale (good 1-2, poor 3-5). Neuron-specific enolase was collected at 72 hours. Imaging and neurophysiologic exams were carried out in the 24 hours after the rewarming period. Results Sixty-seven patients were included in the study, of which 12 had good neurological outcomes. Ventricular fibrillation and electroencephalographic theta activity were associated with increased likelihood of survival and improved neurological outcomes. Patients who had more rapid cooling (mean time of 163 versus 312 minutes), hypoxic-ischemic brain injury on magnetic resonance imaging or neuron-specific enolase > 58ng/mL had poor neurological outcomes (p < 0.05). Conclusion Hypoxic-ischemic brain injury on magnetic resonance imaging and neuron-specific enolase were strong predictors of poor neurological outcomes. Although there is the belief that early achievement of target temperature improves neurological prognoses, in our study, there were increased mortality and worse neurological outcomes with earlier target-temperature achievement. PMID:26761469

  16. Image reconstruction in higher dimensions: myocardial perfusion imaging of tracer dynamics with cardiac motion due to deformation and respiration

    NASA Astrophysics Data System (ADS)

    Shrestha, Uttam M.; Seo, Youngho; Botvinick, Elias H.; Gullberg, Grant T.

    2015-11-01

    Myocardial perfusion imaging (MPI) using slow rotating large field of view cameras requires spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration. In vivo, MPI contains additional degrees of freedom involving unavoidable motion of the heart due to quasiperiodic beating and the effects of respiration, which can severely degrade the quality of the images. This work develops a technique for a single photon emission computed tomography (SPECT) that reconstructs the distribution of the radiotracer concentration in the myocardium using a tensor product of different sets of basis functions that approximately describe the spatiotemporal variation of the radiotracer concentration and the motion of the heart. In this study the temporal B-spline basis functions are chosen to reflect the dynamics of the radiotracer, while the intrinsic deformation and the extrinsic motion of the heart are described by a product of a discrete set of Gaussian basis functions. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it deforms due to cardiac beating, and is displaced due to respiratory motion. These results are compared with the conventional 4D-spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. The higher dimensional reconstruction method proposed here improves bias, yet the signal-to-noise ratio (SNR) decreases slightly due to redistribution of the counts over the cardiac-respiratory gates. Additionally, there is a trade-off between the number of gates and the number of projections per gate to achieve high contrast images.

  17. Image reconstruction in higher dimensions: myocardial perfusion imaging of tracer dynamics with cardiac motion due to deformation and respiration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shrestha, Uttam M.; Seo, Youngho; Botvinick, Elias H.

    Myocardial perfusion imaging (MPI) using slow rotating large field of view cameras requires spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration. In vivo, MPI contains additional degrees of freedom involving unavoidable motion of the heart due to quasiperiodic beating and the effects of respiration, which can severely degrade the quality of the images. This work develops a technique for a single photon emission computed tomography (SPECT) that reconstructs the distribution of the radiotracer concentration in the myocardium using a tensor product of different sets of basis functions that approximately describe the spatiotemporal variationmore » of the radiotracer concentration and the motion of the heart. In this study the temporal B-spline basis functions are chosen to reflect the dynamics of the radiotracer, while the intrinsic deformation and the extrinsic motion of the heart are described by a product of a discrete set of Gaussian basis functions. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it deforms due to cardiac beating, and is displaced due to respiratory motion. We find these results are compared with the conventional 4D-spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. The higher dimensional reconstruction method proposed here improves bias, yet the signal-to-noise ratio (SNR) decreases slightly due to redistribution of the counts over the cardiac-respiratory gates. Finally, there is a trade-off between the number of gates and the number of projections per gate to achieve high contrast images.« less

  18. Image reconstruction in higher dimensions: myocardial perfusion imaging of tracer dynamics with cardiac motion due to deformation and respiration.

    PubMed

    Shrestha, Uttam M; Seo, Youngho; Botvinick, Elias H; Gullberg, Grant T

    2015-11-07

    Myocardial perfusion imaging (MPI) using slow rotating large field of view cameras requires spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration. In vivo, MPI contains additional degrees of freedom involving unavoidable motion of the heart due to quasiperiodic beating and the effects of respiration, which can severely degrade the quality of the images. This work develops a technique for a single photon emission computed tomography (SPECT) that reconstructs the distribution of the radiotracer concentration in the myocardium using a tensor product of different sets of basis functions that approximately describe the spatiotemporal variation of the radiotracer concentration and the motion of the heart. In this study the temporal B-spline basis functions are chosen to reflect the dynamics of the radiotracer, while the intrinsic deformation and the extrinsic motion of the heart are described by a product of a discrete set of Gaussian basis functions. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it deforms due to cardiac beating, and is displaced due to respiratory motion. These results are compared with the conventional 4D-spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. The higher dimensional reconstruction method proposed here improves bias, yet the signal-to-noise ratio (SNR) decreases slightly due to redistribution of the counts over the cardiac-respiratory gates. Additionally, there is a trade-off between the number of gates and the number of projections per gate to achieve high contrast images.

  19. Chronic AMPK activity dysregulation produces myocardial insulin resistance in the human Arg302Gln-PRKAG2 glycogen storage disease mouse model

    PubMed Central

    2013-01-01

    Background The cardiac PRKAG2 mutation in the γ2-subunit of adenosine monophosphate activated kinase (AMPK) is characterized by excessive glycogen deposition, hypertrophy, frequent arrhythmias, and progressive conduction system disease. We investigated whether myocardial glucose uptake (MGU) was augmented following insulin stimulation in a mouse model of the PRKAG2 cardiac syndrome. Methods Myocardial and skeletal muscle glucose uptake was assessed with 2-[18F]fluoro-2-deoxyglucose positron emission tomography imaging in n = 3 transgenic wildtype (TGwt) vs n = 7 PRKAG2 mutant (TGmut) mice at baseline and 1 week later, 30 min following acute insulin. Systolic function, cardiac glycogen stores, phospho-AMPK α, and insulin-receptor expression levels were analyzed to corroborate to the in vivo findings. Results TGmut Patlak Ki was reduced 56% at baseline compared to TGwt (0.3 ± 0.2 vs 0.7 ± 0.1, t test p = 0.01). MGU was augmented 71% in TGwt mice following acute insulin from baseline (0.7 ± 0.1 to 1.2 ± 0.2, t test p < 0.05). No change was observed in TGmut mice. As expected for this cardiac specific transgene, skeletal muscle was unaffected at baseline with a 33% to 38% increase (standard uptake values) for both genotypes following insulin stimulation. TGmut mice had a 47% reduction in systolic function with a fourfold increase in cardiac glycogen stores correlated with a 29% reduction in phospho-AMPK α levels. There was no difference in cardiac insulin receptor expression between mouse genotypes. Conclusions These results demonstrate a correlation between insulin resistance and AMPK activity and provide the basis for the use of this animal model for assessing metabolic therapy in the treatment of affected PRKAG2 patients. PMID:23829931

  20. Virtual and augmented medical imaging environments: enabling technology for minimally invasive cardiac interventional guidance.

    PubMed

    Linte, Cristian A; White, James; Eagleson, Roy; Guiraudon, Gérard M; Peters, Terry M

    2010-01-01

    Virtual and augmented reality environments have been adopted in medicine as a means to enhance the clinician's view of the anatomy and facilitate the performance of minimally invasive procedures. Their value is truly appreciated during interventions where the surgeon cannot directly visualize the targets to be treated, such as during cardiac procedures performed on the beating heart. These environments must accurately represent the real surgical field and require seamless integration of pre- and intra-operative imaging, surgical tracking, and visualization technology in a common framework centered around the patient. This review begins with an overview of minimally invasive cardiac interventions, describes the architecture of a typical surgical guidance platform including imaging, tracking, registration and visualization, highlights both clinical and engineering accuracy limitations in cardiac image guidance, and discusses the translation of the work from the laboratory into the operating room together with typically encountered challenges.

  1. Noninvasive assessment of the developing Xenopus cardiovascular system using optical coherence tomography

    PubMed Central

    Boppart, Stephen A.; Tearney, Gary J.; Bouma, Brett E.; Southern, James F.; Brezinski, Mark E.; Fujimoto, James G.

    1997-01-01

    Studies investigating normal and abnormal cardiac development are frequently limited by an inability to assess cardiovascular function within the intact organism. In this work, optical coherence tomography (OCT), a new method of micron-scale, noninvasive imaging based on the measurement of backscattered infrared light, was introduced for the high resolution assessment of structure and function in the developing Xenopus laevis cardiovascular system. Microstructural details, such as ventricular size and wall positions, were delineated with OCT at 16-μm resolution and correlated with histology. Three-dimensional representation of the cardiovascular system also was achieved by repeated cross-sectional imaging at intervals of 25 μm. In addition to structural information, OCT provides high speed in vivo axial ranging and imaging, allowing quantitative dynamic activity, such as ventricular ejection fraction, to be assessed. The sensitivity of OCT for dynamic assessment was demonstrated with an inotropic agent that altered cardiac function and dimensions. Optical coherence tomography is an attractive new technology for assessing cardiovascular development because of its high resolution, its ability to image through nontransparent structures, and its inexpensive portable design. In vivo and in vitro imaging are performed at a resolution approaching that of histopathology without the need for animal killing. PMID:9113976

  2. Automated segmentation of cardiac visceral fat in low-dose non-contrast chest CT images

    NASA Astrophysics Data System (ADS)

    Xie, Yiting; Liang, Mingzhu; Yankelevitz, David F.; Henschke, Claudia I.; Reeves, Anthony P.

    2015-03-01

    Cardiac visceral fat was segmented from low-dose non-contrast chest CT images using a fully automated method. Cardiac visceral fat is defined as the fatty tissues surrounding the heart region, enclosed by the lungs and posterior to the sternum. It is measured by constraining the heart region with an Anatomy Label Map that contains robust segmentations of the lungs and other major organs and estimating the fatty tissue within this region. The algorithm was evaluated on 124 low-dose and 223 standard-dose non-contrast chest CT scans from two public datasets. Based on visual inspection, 343 cases had good cardiac visceral fat segmentation. For quantitative evaluation, manual markings of cardiac visceral fat regions were made in 3 image slices for 45 low-dose scans and the Dice similarity coefficient (DSC) was computed. The automated algorithm achieved an average DSC of 0.93. Cardiac visceral fat volume (CVFV), heart region volume (HRV) and their ratio were computed for each case. The correlation between cardiac visceral fat measurement and coronary artery and aortic calcification was also evaluated. Results indicated the automated algorithm for measuring cardiac visceral fat volume may be an alternative method to the traditional manual assessment of thoracic region fat content in the assessment of cardiovascular disease risk.

  3. 23-year experience on diagnosis and surgical treatment of benign and malignant cardiac tumors.

    PubMed

    Kośmider, Anna; Jaszewski, Ryszard; Marcinkiewicz, Anna; Bartczak, Karol; Knopik, Jerzy; Ostrowski, Stanisław

    2013-10-31

    Although myxoma is the most frequent cardiac tumor, other conditions should be taken into consideration in the differential diagnosis. Transthoracic echocardiography (TTE), followed by transesophageal echocardiography (TEE) remain the principal methods for cardiac tumor screening and visualizing. The aim of the study was to compare the diagnostics, surgical treatment and prognosis of malignant and benign cardiac tumors. From 1986 to 2009 there were 121 patients with cardiac tumors operated on in the Cardiac Surgery Clinic of the Medical University in Lodz. Patients were referred to surgery mainly on the basis of the TTE and TEE image. In 4 cases valvular prosthesis implantation or valve repair were carried out. Patients remained under long-term observation in the Cardiac Surgery Outpatient Clinic. Myxoma was diagnosed in 114 cases. Malignancies were discovered in 7 cases. The left atrium was the most frequent localization. The echocardiographic image differed significantly in benign and malignant tumors. The postoperative period was complicated by embolic events or myocardial infarctions. Only malignant tumors were associated with mortality due to cardiovascular events. The survival for malignant tumors was significantly shorter. Short and long-term results of operative treatment are very good for benign tumors in contrast to cardiac malignancies. The TTE and TEE image can be very significant in the final diagnosis.

  4. Cardiac Magnetic Resonance Imaging for the Diagnosis of Coronary Artery Disease

    PubMed Central

    2010-01-01

    Executive Summary In July 2009, the Medical Advisory Secretariat (MAS) began work on Non-Invasive Cardiac Imaging Technologies for the Diagnosis of Coronary Artery Disease (CAD), an evidence-based review of the literature surrounding different cardiac imaging modalities to ensure that appropriate technologies are accessed by patients suspected of having CAD. This project came about when the Health Services Branch at the Ministry of Health and Long-Term Care asked MAS to provide an evidentiary platform on effectiveness and cost-effectiveness of non-invasive cardiac imaging modalities. After an initial review of the strategy and consultation with experts, MAS identified five key non-invasive cardiac imaging technologies for the diagnosis of CAD. Evidence-based analyses have been prepared for each of these five imaging modalities: cardiac magnetic resonance imaging, single photon emission computed tomography, 64-slice computed tomographic angiography, stress echocardiography, and stress echocardiography with contrast. For each technology, an economic analysis was also completed (where appropriate). A summary decision analytic model was then developed to encapsulate the data from each of these reports (available on the OHTAC and MAS website). The Non-Invasive Cardiac Imaging Technologies for the Diagnosis of Coronary Artery Disease series is made up of the following reports, which can be publicly accessed at the MAS website at: www.health.gov.on.ca/mas or at www.health.gov.on.ca/english/providers/program/mas/mas_about.html Single Photon Emission Computed Tomography for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis Stress Echocardiography for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis Stress Echocardiography with Contrast for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis 64-Slice Computed Tomographic Angiography for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis Cardiac Magnetic Resonance Imaging for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis Pease note that two related evidence-based analyses of non-invasive cardiac imaging technologies for the assessment of myocardial viability are also available on the MAS website: Positron Emission Tomography for the Assessment of Myocardial Viability: An Evidence-Based Analysis Magnetic Resonance Imaging for the Assessment of Myocardial Viability: an Evidence-Based Analysis The Toronto Health Economics and Technology Assessment Collaborative has also produced an associated economic report entitled: The Relative Cost-effectiveness of Five Non-invasive Cardiac Imaging Technologies for Diagnosing Coronary Artery Disease in Ontario [Internet]. Available from: http://theta.utoronto.ca/reports/?id=7 Objective The objective of this analysis was to determine the diagnostic accuracy of cardiac magnetic resonance imaging (MRI) for the diagnosis of patients with known/suspected coronary artery disease (CAD) compared to coronary angiography. Cardiac MRI Stress cardiac MRI is a non-invasive, x-ray free imaging technique that takes approximately 30 to 45 minutes to complete and can be performed using to two different methods, a) perfusion imaging following a first pass of an intravenous bolus of gadolinium contrast, or b) wall motion imaging. Stress is induced pharmacologically with either dobutamine, dipyridamole, or adenosine, as physical exercise is difficult to perform within the magnet bore and often induces motion artifacts. Alternatives to stress cardiac perfusion MRI include stress single-photon emission computed tomography (SPECT) and stress echocardiography (ECHO). The advantage of cardiac MRI is that it does not pose the radiation burden associated with SPECT. During the same sitting, cardiac MRI can also assess left and right ventricular dimensions, viability, and cardiac mass. It may also mitigate the need for invasive diagnostic coronary angiography in patients with intermediate risk factors for CAD. Evidence-Based Analysis Literature Search A literature search was performed on October 9, 2009 using OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, EMBASE, the Cumulative Index to Nursing & Allied Health Literature (CINAHL), the Cochrane Library, and the International Agency for Health Technology Assessment (INAHTA) for studies published from January 1, 2005 to October 9, 2008. Abstracts were reviewed by a single reviewer and, for those studies meeting the eligibility criteria, full-text articles were obtained. Reference lists were also examined for any relevant studies not identified through the search. Articles with unknown eligibility were reviewed with a second clinical epidemiologist and then a group of epidemiologists until consensus was established. The quality of evidence was assessed as high, moderate, low or very low according to GRADE methodology. Given the large amount of clinical heterogeneity of the articles meeting the inclusion criteria, as well as suggestions from an Expert Advisory Panel Meeting held on October 5, 2009, the inclusion criteria were revised to examine the effectiveness of cardiac MRI for the detection of CAD. Inclusion Criteria Exclusion Criteria Heath technology assessments, systematic reviews, randomized controlled trials, observational studies ≥20 adult patients enrolled. Published 2004-2009 Licensed by Health Canada For diagnosis of CAD: Reference standard is coronary angiography Significant CAD defined as ≥ 50% coronary stenosis Patients with suspected or known CAD Reported results by patient, not segment Non-English studies Grey literature Planar imaging MUGA Patients with recent MI (i.e., within 1 month) Patients with non-ischemic heart disease Studies done exclusively in special populations (e.g., women, diabetics) Outcomes of Interest Sensitivity and specificity Area under the curve (AUC) Diagnostic odds ratio (DOR) Summary of Findings Stress cardiac MRI using perfusion analysis yielded a pooled sensitivity of 0.91 (95% CI: 0.89 to 0.92) and specificity of 0.79 (95% CI: 0.76 to 0.82) for the detection of CAD. Stress cardiac MRI using wall motion analysis yielded a pooled sensitivity of 0.81 (95% CI: 0.77 to 0.84) and specificity of 0.85 (95% CI: 0.81 to 0.89) for the detection of CAD. Based on DORs, there was no significant difference between pooled stress cardiac MRI using perfusion analysis and pooled stress cardiac MRI using wall motion analysis (P=0.26) for the detection of CAD. Pooled subgroup analysis of stress cardiac MRI using perfusion analysis showed no significant difference in the DORs between 1.5T and 3T MRI (P=0.72) for the detection of CAD. One study (N=60) was identified that examined stress cardiac MRI using wall motion analysis with a 3T MRI. The sensitivity and specificity of 3T MRI were 0.64 (95% CI: 0.44 to 0.81) and 1.00 (95% CI: 0.89 to 1.00), respectively, for the detection of CAD. The effectiveness of stress cardiac MRI for the detection of CAD in unstable patients with acute coronary syndrome was reported in only one study (N=35). Using perfusion analysis, the sensitivity and specificity were 0.72 (95% CI: 0.53 to 0.87) and 1.00 (95% CI: 0.54 to 1.00), respectively, for the detection of CAD. Ontario Health System Impact Analysis According to an expert consultant, in Ontario: Stress first pass perfusion is currently performed in small numbers in London (London Health Sciences Centre) and Toronto (University Health Network at the Toronto General Hospital site and Sunnybrook Health Sciences Centre). Stress wall motion is only performed as part of research protocols and not very often. Cardiac MRI machines use 1.5T almost exclusively, with 3T used in research for first pass perfusion. On November 25 2009, the Cardiac Imaging Expert Advisory Panel met and made the following comments about stress cardiac MRI for perfusion analysis: Accessibility to cardiac MRI is limited and generally used to assess structural abnormalities. Most MRIs in Ontario are already in 24–hour, constant use and it would thus be difficult to add cardiac MRI for CAD diagnosis as an additional indication. The performance of cardiac MRI for the diagnosis of CAD can be technically challenging. GRADE Quality of Evidence for Cardiac MRI in the Diagnosis of CAD The quality of the body of evidence was assessed according to the GRADE Working Group criteria for diagnostic tests. For perfusion analysis, the overall quality was determined to be low and for wall motion analysis the overall quality was very low. PMID:23074389

  5. Optimized protocols for cardiac magnetic resonance imaging in patients with thoracic metallic implants.

    PubMed

    Olivieri, Laura J; Cross, Russell R; O'Brien, Kendall E; Ratnayaka, Kanishka; Hansen, Michael S

    2015-09-01

    Cardiac magnetic resonance (MR) imaging is a valuable tool in congenital heart disease; however patients frequently have metal devices in the chest from the treatment of their disease that complicate imaging. Methods are needed to improve imaging around metal implants near the heart. Basic sequence parameter manipulations have the potential to minimize artifact while limiting effects on image resolution and quality. Our objective was to design cine and static cardiac imaging sequences to minimize metal artifact while maintaining image quality. Using systematic variation of standard imaging parameters on a fluid-filled phantom containing commonly used metal cardiac devices, we developed optimized sequences for steady-state free precession (SSFP), gradient recalled echo (GRE) cine imaging, and turbo spin-echo (TSE) black-blood imaging. We imaged 17 consecutive patients undergoing routine cardiac MR with 25 metal implants of various origins using both standard and optimized imaging protocols for a given slice position. We rated images for quality and metal artifact size by measuring metal artifact in two orthogonal planes within the image. All metal artifacts were reduced with optimized imaging. The average metal artifact reduction for the optimized SSFP cine was 1.5+/-1.8 mm, and for the optimized GRE cine the reduction was 4.6+/-4.5 mm (P < 0.05). Quality ratings favored the optimized GRE cine. Similarly, the average metal artifact reduction for the optimized TSE images was 1.6+/-1.7 mm (P < 0.05), and quality ratings favored the optimized TSE imaging. Imaging sequences tailored to minimize metal artifact are easily created by modifying basic sequence parameters, and images are superior to standard imaging sequences in both quality and artifact size. Specifically, for optimized cine imaging a GRE sequence should be used with settings that favor short echo time, i.e. flow compensation off, weak asymmetrical echo and a relatively high receiver bandwidth. For static black-blood imaging, a TSE sequence should be used with fat saturation turned off and high receiver bandwidth.

  6. 4D micro-CT using fast prospective gating

    NASA Astrophysics Data System (ADS)

    Guo, Xiaolian; Johnston, Samuel M.; Qi, Yi; Johnson, G. Allan; Badea, Cristian T.

    2012-01-01

    Micro-CT is currently used in preclinical studies to provide anatomical information. But, there is also significant interest in using this technology to obtain functional information. We report here a new sampling strategy for 4D micro-CT for functional cardiac and pulmonary imaging. Rapid scanning of free-breathing mice is achieved with fast prospective gating (FPG) implemented on a field programmable gate array. The method entails on-the-fly computation of delays from the R peaks of the ECG signals or the peaks of the respiratory signals for the triggering pulses. Projection images are acquired for all cardiac or respiratory phases at each angle before rotating to the next angle. FPG can deliver the faster scan time of retrospective gating (RG) with the regular angular distribution of conventional prospective gating for cardiac or respiratory gating. Simultaneous cardio-respiratory gating is also possible with FPG in a hybrid retrospective/prospective approach. We have performed phantom experiments to validate the new sampling protocol and compared the results from FPG and RG in cardiac imaging of a mouse. Additionally, we have evaluated the utility of incorporating respiratory information in 4D cardiac micro-CT studies with FPG. A dual-source micro-CT system was used for image acquisition with pulsed x-ray exposures (80 kVp, 100 mA, 10 ms). The cardiac micro-CT protocol involves the use of a liposomal blood pool contrast agent containing 123 mg I ml-1 delivered via a tail vein catheter in a dose of 0.01 ml g-1 body weight. The phantom experiment demonstrates that FPG can distinguish the successive phases of phantom motion with minimal motion blur, and the animal study demonstrates that respiratory FPG can distinguish inspiration and expiration. 4D cardiac micro-CT imaging with FPG provides image quality superior to RG at an isotropic voxel size of 88 µm and 10 ms temporal resolution. The acquisition time for either sampling approach is less than 5 min. The radiation dose associated with the proposed method is in the range of a typical micro-CT dose (256 mGy for the cardiac study). Ignoring respiration does not significantly affect anatomic information in cardiac studies. FPG can deliver short scan times with low-dose 4D micro-CT imaging without sacrificing image quality. FPG can be applied in high-throughput longitudinal studies in a wide range of applications, including drug safety and cardiopulmonary phenotyping.

  7. Nuclear cardiac

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slutsky, R.; Ashburn, W.L.

    1982-01-01

    The relationship between nuclear medicine and cardiology has continued to produce a surfeit of interesting, illuminating, and important reports involving the analysis of cardiac function, perfusion, and metabolism. To simplify the presentation, this review is broken down into three major subheadings: analysis of myocardial perfusion; imaging of the recent myocardial infarction; and the evaluation of myocardial function. There appears to be an increasingly important relationship between cardiology, particularly cardiac physiology, and nuclear imaging techniques. (KRM)

  8. [Fever, atrial fibrillation, and angina pectoris in a 58-year-old man].

    PubMed

    Groebner, M; Südhoff, T; Doering, M; Kirmayer, M; Nitsch, T; Prügl, L; Römer, W; Wolf, H; Tacke, J; Massoudy, P; Nüsse, T; Elsner, D

    2014-05-01

    Primary cardiac lymphoma (PCL) respresents a very rare type of cardiac tumour. This report illustrates a case of PCL in an immunocompetent 58-year-old man presenting with atrial fibrillation and febrile syndrome. Comprehensive imaging [computer tomography (CT), cardiac magnetic resonance imaging (cMRI), 3-dimensional transesophageal echocardiography (3D-TEE)] identified a large right atrial tumour, leading to pericardial effusion. Isolated cardiac involvement was confirmed by positron emission tomography (PET)-CT. A diffuse large B-cell lymphoma (DLBCL) was diagnosed based on the results of a TEE-guided biopsy. A normalized PET scan (PETAL study) indicated complete remission following R-CHOP 14 immunochemotherapy. Thus, an interdisciplinary and multimodal approach avoided unnecessary cardiac surgery.

  9. Addressing Common Questions Encountered in the Diagnosis and Management of Cardiac Amyloidosis.

    PubMed

    Maurer, Mathew S; Elliott, Perry; Comenzo, Raymond; Semigran, Marc; Rapezzi, Claudio

    2017-04-04

    Advances in cardiac imaging have resulted in greater recognition of cardiac amyloidosis in everyday clinical practice, but the diagnosis continues to be made in patients with late-stage disease, suggesting that more needs to be done to improve awareness of its clinical manifestations and the potential of therapeutic intervention to improve prognosis. Light chain cardiac amyloidosis, in particular, if recognized early and treated with targeted plasma cell therapy, can be managed very effectively. For patients with transthyretin amyloidosis, there are numerous therapies that are currently in late-phase clinical trials. In this review, we address common questions encountered in clinical practice regarding etiology, clinical presentation, diagnosis, and management of cardiac amyloidosis, focusing on recent important developments in cardiac imaging and biochemical diagnosis. The aim is to show how a systematic approach to the evaluation of suspected cardiac amyloidosis can impact the prognosis of patients in the modern era. © 2017 American Heart Association, Inc.

  10. C.A.U.S.E.: Cardiac arrest ultra-sound exam--a better approach to managing patients in primary non-arrhythmogenic cardiac arrest.

    PubMed

    Hernandez, Caleb; Shuler, Klaus; Hannan, Hashibul; Sonyika, Chionesu; Likourezos, Antonios; Marshall, John

    2008-02-01

    Cardiac arrest is a condition frequently encountered by physicians in the hospital setting including the Emergency Department, Intensive Care Unit and medical/surgical wards. This paper reviews the current literature involving the use of ultrasound in resuscitation and proposes an algorithmic approach for the use of ultrasound during cardiac arrest. At present there is the need for a means of differentiating between various causes of cardiac arrest, which are not a direct result of a primary ventricular arrhythmia. Identifying the cause of pulseless electrical activity or asystole is important as the underlying cause is what guides management in such cases. This approach, incorporating ultrasound to manage cardiac arrest aids in the diagnosis of the most common and easily reversible causes of cardiac arrest not caused by primary ventricular arrhythmia, namely; severe hypovolemia, tension pneumothorax, cardiac tamponade, and massive pulmonary embolus. These four conditions are addressed in this paper using four accepted emergency ultrasound applications to be performed during resuscitation of a cardiac arrest patient with the aim of determining the underlying cause of a cardiac arrest. Identifying the underlying cause of cardiac arrest represents the one of the greatest challenges of managing patients with asystole or PEA and accurate determination has the potential to improve management by guiding therapeutic decisions. We include several clinical images demonstrating examples of cardiac tamponade, massive pulmonary embolus, and severe hypovolemia secondary to abdominal aortic aneurysm. In conclusion, this protocol has the potential to reduce the time required to determine the etiology of a cardiac arrest and thus decrease the time between arrest and appropriate therapy.

  11. The use of imaging for electrophysiological and devices procedures: a report from the first European Heart Rhythm Association Policy Conference, jointly organized with the European Association of Cardiovascular Imaging (EACVI), the Council of Cardiovascular Imaging and the European Society of Cardiac Radiology.

    PubMed

    Blomström Lundqvist, Carina; Auricchio, Angelo; Brugada, Josep; Boriani, Giuseppe; Bremerich, Jens; Cabrera, Jose Angel; Frank, Herbert; Gutberlet, Matthias; Heidbuchel, Hein; Kuck, Karl-Heinz; Lancellotti, Patrizio; Rademakers, Frank; Winkels, Gerard; Wolpert, Christian; Vardas, Panos E

    2013-07-01

    Implantations of cardiac devices therapies and ablation procedures frequently depend on accurate and reliable imaging modalities for pre-procedural assessments, intra-procedural guidance, detection of complications, and the follow-up of patients. An understanding of echocardiography, cardiovascular magnetic resonance imaging, nuclear cardiology, X-ray computed tomography, positron emission tomography, and vascular ultrasound is indispensable for cardiologists, electrophysiologists as well as radiologists, and it is currently recommended that physicians should be trained in several imaging modalities. There are, however, no current guidelines or recommendations by electrophysiologists, cardiac imaging specialists, and radiologists, on the appropriate use of cardiovascular imaging for selected patient indications, which needs to be addressed. A Policy Conference on the use of imaging in electrophysiology and device management, with representatives from different expert areas of radiology and electrophysiology and commercial developers of imaging and device technologies, was therefore jointly organized by European Heart Rhythm Association (EHRA), the Council of Cardiovascular Imaging and the European Society of Cardiac Radiology (ESCR). The objectives were to assess the state of the level of evidence and a first step towards a consensus document for currently employed imaging techniques to guide future clinical use, to elucidate the issue of reimbursement structures and health economy, and finally to define the need for appropriate educational programmes to ensure clinical competence for electrophysiologists, imaging specialists, and radiologists.

  12. Ultrasound Current Source Density Imaging in live rabbit hearts using clinical intracardiac catheter

    NASA Astrophysics Data System (ADS)

    Li, Qian

    Ultrasound Current Source Density Imaging (UCSDI) is a noninvasive modality for mapping electrical activities in the body (brain and heart) in 4-dimensions (space + time). Conventional cardiac mapping technologies for guiding the radiofrequency ablation procedure for treatment of cardiac arrhythmias have certain limitations. UCSDI can potentially overcome these limitations and enhance the electrophysiology mapping of the heart. UCSDI exploits the acoustoelectric (AE) effect, an interaction between ultrasound pressure and electrical resistivity. When an ultrasound beam intersects a current path in a material, the local resistivity of the material is modulated by the ultrasonic pressure, and a change in voltage signal can be detected based on Ohm's Law. The degree of modulation is determined by the AE interaction constant K. K is a fundamental property of any type of material, and directly affects the amplitude of the AE signal detected in UCSDI. UCSDI requires detecting a small AE signal associated with electrocardiogram. So sensitivity becomes a major challenge for transferring UCSDI to the clinic. This dissertation will determine the limits of sensitivity and resolution for UCSDI, balancing the tradeoff between them by finding the optimal parameters for electrical cardiac mapping, and finally test the optimized system in a realistic setting. This work begins by describing a technique for measuring K, the AE interaction constant, in ionic solution and biological tissue, and reporting the value of K in excised rabbit cardiac tissue for the first time. K was found to be strongly dependent on concentration for the divalent salt CuSO4, but not for the monovalent salt NaCl, consistent with their different chemical properties. In the rabbit heart tissue, K was determined to be 0.041 +/- 0.012 %/MPa, similar to the measurement of K in physiologic saline: 0.034 +/- 0.003 %/MPa. Next, this dissertation investigates the sensitivity limit of UCSDI by quantifying the relation between the recording electrode distance and the measured AE signal amplitude in gel phantoms and excised porcine heart tissue using a clinical intracardiac catheter. Sensitivity of UCSDI with catheter was 4.7 microV/mA (R2 = 0.999) in cylindrical gel (0.9% NaCl), and 3.2 microV/mA (R2 = 0.92) in porcine heart tissue. The AE signal was detectable more than 25 mm away from the source in cylindrical gel (0.9% NaCl). Effect of transducer properties on UCSDI sensitivity is also investigated using simulation. The optimal ultrasound transducer parameters chosen for cardiac imaging are center frequency = 0.5 MHz and f/number = 1.4. Last but not least, this dissertation shows the result of implementing the optimized ultrasound parameters in live rabbit heart preparation, the comparison of different recording electrode configuration and multichannel UCSDI recording and reconstruction. The AE signal detected using the 0.5 MHz transducer was much stronger (2.99 microV/MPa) than the 1.0 MHz transducer (0.42 microV/MPa). The clinical lasso catheter placed on the epicardium exhibited excellent sensitivity without being too invasive. 3-dimensional cardiac activation maps of the live rabbit heart using only one pair of recording electrodes were also demonstrated for the first time. Cardiac conduction velocity for atrial (1.31 m/s) and apical (0.67 m/s) pacing were calculated based on the activation maps. The future outlook of this dissertation includes integrating UCSDI with 2-dimensional ultrasound transducer array for fast imaging, and developing a multi-modality catheter with 4-dimensional UCSDI, multi-electrode recording and echocardiography capacity.

  13. External cardiac compression may be harmful in some scenarios of pulseless electrical activity.

    PubMed

    Hogan, T S

    2012-10-01

    Pulseless electrical activity occurs when organised or semi-organised electrical activity of the heart persists but the product of systemic vascular resistance and the increase in systemic arterial flow generated by the ejection of the left venticular stroke volume is not sufficient to produce a clinically detectable pulse. Pulseless electrical activity encompasses a very heterogeneous variety of severe circulatory shock states ranging in severity from pseudo-cardiac arrest to effective cardiac arrest. Outcomes of cardiopulmonary resuscitation for pulseless electrical activity are generally poor. Impairment of cardiac filling is the limiting factor to cardiac output in many scenarios of pulseless electrical activity, including extreme vasodilatory shock states. There is no evidence that external cardiac compression can increase cardiac output when impaired cardiac filling is the limiting factor to cardiac output. If impaired cardiac filling is the limiting factor to cardiac output and the heart is effectively ejecting all the blood returning to it, then external cardiac compression can only increase cardiac output if it increases venous return and cardiac filling. Repeated cardiac compression asynchronous with the patient's cardiac cycle and raised mean intrathoracic pressure due to chest compression can be expected to reduce rather than to increase cardiac filling and therefore to reduce rather than to increase cardiac output in such circumstances. The hypothesis is proposed that the performance of external cardiac compression will have zero or negative effect on cardiac output in pulseless electrical activity when impaired cardiac filling is the limiting factor to cardiac output. External cardiac compression may be both directly and indirectly harmful to significant sub-groups of patients with pulseless electrical activity. We have neither evidence nor theory to provide comfort that external cardiac compression is not harmful in many scenarios of pulseless electrical activity. Investigation using a variety of animal models of pulseless electrical activity produced by different shock-inducing mechanisms is required to provide an evidence base for resuscitation guidelines. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Intravital imaging of cardiac function at the single-cell level.

    PubMed

    Aguirre, Aaron D; Vinegoni, Claudio; Sebas, Matt; Weissleder, Ralph

    2014-08-05

    Knowledge of cardiomyocyte biology is limited by the lack of methods to interrogate single-cell physiology in vivo. Here we show that contracting myocytes can indeed be imaged with optical microscopy at high temporal and spatial resolution in the beating murine heart, allowing visualization of individual sarcomeres and measurement of the single cardiomyocyte contractile cycle. Collectively, this has been enabled by efficient tissue stabilization, a prospective real-time cardiac gating approach, an image processing algorithm for motion-artifact-free imaging throughout the cardiac cycle, and a fluorescent membrane staining protocol. Quantification of cardiomyocyte contractile function in vivo opens many possibilities for investigating myocardial disease and therapeutic intervention at the cellular level.

  15. Tracking brain motion during the cardiac cycle using spiral cine-DENSE MRI

    PubMed Central

    Zhong, Xiaodong; Meyer, Craig H.; Schlesinger, David J.; Sheehan, Jason P.; Epstein, Frederick H.; Larner, James M.; Benedict, Stanley H.; Read, Paul W.; Sheng, Ke; Cai, Jing

    2009-01-01

    Cardiac-synchronized brain motion is well documented, but the accurate measurement of such motion on the pixel-by-pixel basis has been hampered by the lack of proper imaging technique. In this article, the authors present the implementation of an autotracking spiral cine displacement-encoded stimulation echo (DENSE) magnetic resonance imaging (MRI) technique for the measurement of pulsatile brain motion during the cardiac cycle. Displacement-encoded dynamic MR images of three healthy volunteers were acquired throughout the cardiac cycle using the spiral cine-DENSE pulse sequence gated to the R wave of an electrocardiogram. Pixelwise Lagrangian displacement maps were computed, and 2D displacement as a function of time was determined for selected regions of interests. Different intracranial structures exhibited characteristic motion amplitude, direction, and pattern throughout the cardiac cycle. Time-resolved displacement curves revealed the pathway of pulsatile motion from brain stem to peripheral brain lobes. These preliminary results demonstrated that the spiral cine-DENSE MRI technique can be used to measure cardiac-synchronized pulsatile brain motion on the pixel-by-pixel basis with high temporal∕spatial resolution and sensitivity. PMID:19746774

  16. Image registration and analysis for quantitative myocardial perfusion: application to dynamic circular cardiac CT.

    PubMed

    Isola, A A; Schmitt, H; van Stevendaal, U; Begemann, P G; Coulon, P; Boussel, L; Grass, M

    2011-09-21

    Large area detector computed tomography systems with fast rotating gantries enable volumetric dynamic cardiac perfusion studies. Prospectively, ECG-triggered acquisitions limit the data acquisition to a predefined cardiac phase and thereby reduce x-ray dose and limit motion artefacts. Even in the case of highly accurate prospective triggering and stable heart rate, spatial misalignment of the cardiac volumes acquired and reconstructed per cardiac cycle may occur due to small motion pattern variations from cycle to cycle. These misalignments reduce the accuracy of the quantitative analysis of myocardial perfusion parameters on a per voxel basis. An image-based solution to this problem is elastic 3D image registration of dynamic volume sequences with variable contrast, as it is introduced in this contribution. After circular cone-beam CT reconstruction of cardiac volumes covering large areas of the myocardial tissue, the complete series is aligned with respect to a chosen reference volume. The results of the registration process and the perfusion analysis with and without registration are evaluated quantitatively in this paper. The spatial alignment leads to improved quantification of myocardial perfusion for three different pig data sets.

  17. C-SPECT - a Clinical Cardiac SPECT/Tct Platform: Design Concepts and Performance Potential

    PubMed Central

    Chang, Wei; Ordonez, Caesar E.; Liang, Haoning; Li, Yusheng; Liu, Jingai

    2013-01-01

    Because of scarcity of photons emitted from the heart, clinical cardiac SPECT imaging is mainly limited by photon statistics. The sub-optimal detection efficiency of current SPECT systems not only limits the quality of clinical cardiac SPECT imaging but also makes more advanced potential applications difficult to be realized. We propose a high-performance system platform - C-SPECT, which has its sampling geometry optimized for detection of emitted photons in quality and quantity. The C-SPECT has a stationary C-shaped gantry that surrounds the left-front side of a patient’s thorax. The stationary C-shaped collimator and detector systems in the gantry provide effective and efficient detection and sampling of photon emission. For cardiac imaging, the C-SPECT platform could achieve 2 to 4 times the system geometric efficiency of conventional SPECT systems at the same sampling resolution. This platform also includes an integrated transmission CT for attenuation correction. The ability of C-SPECT systems to perform sequential high-quality emission and transmission imaging could bring cost-effective high-performance to clinical imaging. In addition, a C-SPECT system could provide high detection efficiency to accommodate fast acquisition rate for gated and dynamic cardiac imaging. This paper describes the design concepts and performance potential of C-SPECT, and illustrates how these concepts can be implemented in a basic system. PMID:23885129

  18. PET imaging of cardiac hypoxia: Opportunities and challenges

    PubMed Central

    Handley, M.G.; Medina, R.A.; Nagel, E.; Blower, P.J.; Southworth, R.

    2012-01-01

    Myocardial hypoxia is a major factor in the pathology of cardiac ischemia and myocardial infarction. Hypoxia also occurs in microvascular disease and cardiac hypertrophy, and is thought to be a prime determinant of the progression to heart failure, as well as the driving force for compensatory angiogenesis. The non-invasive delineation and quantification of hypoxia in cardiac tissue therefore has the potential to be an invaluable experimental, diagnostic and prognostic biomarker for applications in cardiology. However, at this time there are no validated methodologies sufficiently sensitive or reliable for clinical use. PET imaging provides real-time spatial information on the biodistribution of injected radiolabeled tracer molecules. Its inherent high sensitivity allows quantitative imaging of these tracers, even when injected at sub-pharmacological (≥pM) concentrations, allowing the non-invasive investigation of biological systems without perturbing them. PET is therefore an attractive approach for the delineation and quantification of cardiac hypoxia and ischemia. In this review we discuss the key concepts which must be considered when imaging hypoxia in the heart. We summarize the PET tracers which are currently available, and we look forward to the next generation of hypoxia-specific PET imaging agents currently being developed. We describe their potential advantages and shortcomings compared to existing imaging approaches, and what is needed in terms of validation and characterization before these agents can be exploited clinically. PMID:21781973

  19. Hybrid cardiac imaging using PET/MRI: a joint position statement by the European Society of Cardiovascular Radiology (ESCR) and the European Association of Nuclear Medicine (EANM).

    PubMed

    Nensa, Felix; Bamberg, Fabian; Rischpler, Christoph; Menezes, Leon; Poeppel, Thorsten D; la Fougère, Christian; Beitzke, Dietrich; Rasul, Sazan; Loewe, Christian; Nikolaou, Konstantin; Bucerius, Jan; Kjaer, Andreas; Gutberlet, Matthias; Prakken, Niek H; Vliegenthart, Rozemarijn; Slart, Riemer H J A; Nekolla, Stephan G; Lassen, Martin L; Pichler, Bernd J; Schlosser, Thomas; Jacquier, Alexis; Quick, Harald H; Schäfers, Michael; Hacker, Marcus

    2018-05-02

    Positron emission tomography (PET) and magnetic resonance imaging (MRI) have both been used for decades in cardiovascular imaging. Since 2010, hybrid PET/MRI using sequential and integrated scanner platforms has been available, with hybrid cardiac PET/MR imaging protocols increasingly incorporated into clinical workflows. Given the range of complementary information provided by each method, the use of hybrid PET/MRI may be justified and beneficial in particular clinical settings for the evaluation of different disease entities. In the present joint position statement, we critically review the role and value of integrated PET/MRI in cardiovascular imaging, provide a technical overview of cardiac PET/MRI and practical advice related to the cardiac PET/MRI workflow, identify cardiovascular applications that can potentially benefit from hybrid PET/MRI, and describe the needs for future development and research. In order to encourage its wide dissemination, this article is freely accessible on the European Radiology and European Journal of Hybrid Imaging web sites. • Studies and case-reports indicate that PET/MRI is a feasible and robust technology. • Promising fields of application include a variety of cardiac conditions. • Larger studies are required to demonstrate its incremental and cost-effective value. • The translation of novel radiopharmaceuticals and MR-sequences will provide exciting new opportunities.

  20. A comparison study of atlas-based 3D cardiac MRI segmentation: global versus global and local transformations

    NASA Astrophysics Data System (ADS)

    Daryanani, Aditya; Dangi, Shusil; Ben-Zikri, Yehuda Kfir; Linte, Cristian A.

    2016-03-01

    Magnetic Resonance Imaging (MRI) is a standard-of-care imaging modality for cardiac function assessment and guidance of cardiac interventions thanks to its high image quality and lack of exposure to ionizing radiation. Cardiac health parameters such as left ventricular volume, ejection fraction, myocardial mass, thickness, and strain can be assessed by segmenting the heart from cardiac MRI images. Furthermore, the segmented pre-operative anatomical heart models can be used to precisely identify regions of interest to be treated during minimally invasive therapy. Hence, the use of accurate and computationally efficient segmentation techniques is critical, especially for intra-procedural guidance applications that rely on the peri-operative segmentation of subject-specific datasets without delaying the procedure workflow. Atlas-based segmentation incorporates prior knowledge of the anatomy of interest from expertly annotated image datasets. Typically, the ground truth atlas label is propagated to a test image using a combination of global and local registration. The high computational cost of non-rigid registration motivated us to obtain an initial segmentation using global transformations based on an atlas of the left ventricle from a population of patient MRI images and refine it using well developed technique based on graph cuts. Here we quantitatively compare the segmentations obtained from the global and global plus local atlases and refined using graph cut-based techniques with the expert segmentations according to several similarity metrics, including Dice correlation coefficient, Jaccard coefficient, Hausdorff distance, and Mean absolute distance error.

  1. Development of an organ-specific insert phantom generated using a 3D printer for investigations of cardiac computed tomography protocols.

    PubMed

    Abdullah, Kamarul A; McEntee, Mark F; Reed, Warren; Kench, Peter L

    2018-04-30

    An ideal organ-specific insert phantom should be able to simulate the anatomical features with appropriate appearances in the resultant computed tomography (CT) images. This study investigated a 3D printing technology to develop a novel and cost-effective cardiac insert phantom derived from volumetric CT image datasets of anthropomorphic chest phantom. Cardiac insert volumes were segmented from CT image datasets, derived from an anthropomorphic chest phantom of Lungman N-01 (Kyoto Kagaku, Japan). These segmented datasets were converted to a virtual 3D-isosurface of heart-shaped shell, while two other removable inserts were included using computer-aided design (CAD) software program. This newly designed cardiac insert phantom was later printed by using a fused deposition modelling (FDM) process via a Creatbot DM Plus 3D printer. Then, several selected filling materials, such as contrast media, oil, water and jelly, were loaded into designated spaces in the 3D-printed phantom. The 3D-printed cardiac insert phantom was positioned within the anthropomorphic chest phantom and 30 repeated CT acquisitions performed using a multi-detector scanner at 120-kVp tube potential. Attenuation (Hounsfield Unit, HU) values were measured and compared to the image datasets of real-patient and Catphan ® 500 phantom. The output of the 3D-printed cardiac insert phantom was a solid acrylic plastic material, which was strong, light in weight and cost-effective. HU values of the filling materials were comparable to the image datasets of real-patient and Catphan ® 500 phantom. A novel and cost-effective cardiac insert phantom for anthropomorphic chest phantom was developed using volumetric CT image datasets with a 3D printer. Hence, this suggested the printing methodology could be applied to generate other phantoms for CT imaging studies. © 2018 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology.

  2. A Two-dimensional Sixteen Channel Transmit/Receive Coil Array for Cardiac MRI at 7.0 Tesla: Design, Evaluation and Application

    PubMed Central

    Thalhammer, Christof; Renz, Wolfgang; Winter, Lukas; Hezel, Fabian; Rieger, Jan; Pfeiffer, Harald; Graessl, Andreas; Seifert, Frank; Hoffmann, Werner; von Knobelsdorff-Brenkenhoff, Florian; Tkachenko, Valeriy; Schulz-Menger, Jeanette; Kellman, Peter; Niendorf, Thoralf

    2012-01-01

    Purpose To design, evaluate and apply a two-dimensional 16 channel transmit/receive coil array tailored for cardiac MRI at 7.0 Tesla. Material and Methods The cardiac coil array consists of 2 sections each using 8 elements arranged in a 2 × 4 array. RF safety was validated by SAR simulations. Cardiac imaging was performed using 2D CINE FLASH imaging, T2* mapping and fat-water separation imaging. The characteristics of the coil array were analyzed including parallel imaging performance, left ventricular chamber quantification and overall image quality. Results RF characteristics were found to be appropriate for all subjects included in the study. The SAR values derived from the simulations fall well in the limits of legal guidelines. The baseline SNR advantage at 7.0 T was put to use to acquire 2D CINE images of the heart with a very high spatial resolution of (1 × 1 × 4) mm3. The proposed coil array supports 1D acceleration factors of up to R=4 without impairing image quality significantly. Conclusions The 16 channel TX/RX coil has the capability to acquire high contrast and high spatial resolution images of the heart at 7.0 Tesla. PMID:22706727

  3. Using learned under-sampling pattern for increasing speed of cardiac cine MRI based on compressive sensing principles

    NASA Astrophysics Data System (ADS)

    Zamani, Pooria; Kayvanrad, Mohammad; Soltanian-Zadeh, Hamid

    2012-12-01

    This article presents a compressive sensing approach for reducing data acquisition time in cardiac cine magnetic resonance imaging (MRI). In cardiac cine MRI, several images are acquired throughout the cardiac cycle, each of which is reconstructed from the raw data acquired in the Fourier transform domain, traditionally called k-space. In the proposed approach, a majority, e.g., 62.5%, of the k-space lines (trajectories) are acquired at the odd time points and a minority, e.g., 37.5%, of the k-space lines are acquired at the even time points of the cardiac cycle. Optimal data acquisition at the even time points is learned from the data acquired at the odd time points. To this end, statistical features of the k-space data at the odd time points are clustered by fuzzy c-means and the results are considered as the states of Markov chains. The resulting data is used to train hidden Markov models and find their transition matrices. Then, the trajectories corresponding to transition matrices far from an identity matrix are selected for data acquisition. At the end, an iterative thresholding algorithm is used to reconstruct the images from the under-sampled k-space datasets. The proposed approaches for selecting the k-space trajectories and reconstructing the images generate more accurate images compared to alternative methods. The proposed under-sampling approach achieves an acceleration factor of 2 for cardiac cine MRI.

  4. Live dynamic OCT imaging of cardiac structure and function in mouse embryos with 43 Hz direct volumetric data acquisition

    NASA Astrophysics Data System (ADS)

    Wang, Shang; Singh, Manmohan; Lopez, Andrew L.; Wu, Chen; Raghunathan, Raksha; Schill, Alexander; Li, Jiasong; Larin, Kirill V.; Larina, Irina V.

    2016-03-01

    Efficient phenotyping of cardiac dynamics in live mouse embryos has significant implications on understanding of early mammalian heart development and congenital cardiac defects. Recent studies established optical coherence tomography (OCT) as a powerful tool for live embryonic heart imaging in various animal models. However, current four-dimensional (4D) OCT imaging of the beating embryonic heart largely relies on gated data acquisition or postacquisition synchronization, which brings errors when cardiac cycles lack perfect periodicity and is time consuming and computationally expensive. Here, we report direct 4D OCT imaging of the structure and function of cardiac dynamics in live mouse embryos achieved by employing a Fourier domain mode-locking swept laser source that enables ~1.5 MHz A-line rate. Through utilizing both forward and backward scans of a resonant mirror, we obtained a ~6.4 kHz frame rate, which allows for a direct volumetric data acquisition speed of ~43 Hz, around 20 times of the early-stage mouse embryonic heart rate. Our experiments were performed on mouse embryos at embryonic day 9.5. Time-resolved 3D cardiodynamics clearly shows the heart structure in motion. We present analysis of cardiac wall movement and its velocity from the primitive atrium and ventricle. Our results suggest that the combination of ultrahigh-speed OCT imaging with live embryo culture could be a useful embryonic heart phenotyping approach for mouse mutants modeling human congenital heart diseases.

  5. Towards modeling of cardiac micro-structure with catheter-based confocal microscopy: a novel approach for dye delivery and tissue characterization.

    PubMed

    Lasher, Richard A; Hitchcock, Robert W; Sachse, Frank B

    2009-08-01

    This work presents a methodology for modeling of cardiac tissue micro-structure. The approach is based on catheter-based confocal imaging systems, which are emerging as tools for diagnosis in various clinical disciplines. A limitation of these systems is that a fluorescent marker must be available in sufficient concentration in the imaged region. We introduce a novel method for the local delivery of fluorescent markers to cardiac tissue based on a hydro-gel carrier brought into contact with the tissue surface. The method was tested with living rabbit cardiac tissue and applied to acquire three-dimensional image stacks with a standard inverted confocal microscope and two-dimensional images with a catheter-based confocal microscope. We processed these image stacks to obtain spatial models and quantitative data on tissue microstructure. Volumes of atrial and ventricular myocytes were 4901 +/- 1713 and 10 299 +/-3598 mum (3) (mean+/-sd), respectively. Atrial and ventricular myocyte volume fractions were 72.4 +/-4.7% and 79.7 +/- 2.9% (mean +/-sd), respectively. Atrial and ventricular myocyte density was 165 571 +/- 55 836 and 86 957 +/- 32 280 cells/mm (3) (mean+/-sd), respectively. These statistical data and spatial descriptions of tissue microstructure provide important input for modeling studies of cardiac tissue function. We propose that the described methodology can also be used to characterize diseased tissue and allows for personalized modeling of cardiac tissue.

  6. Assessment of Image Quality of Repeated Limited Transthoracic Echocardiography After Cardiac Surgery.

    PubMed

    Canty, David J; Heiberg, Johan; Tan, Jen A; Yang, Yang; Royse, Alistair G; Royse, Colin F; Mobeirek, Abdulelah; Shaer, Fayez El; Albacker, Turki; Nazer, Rakan I; Fouda, Muhammed; Bakir, Bakir M; Alsaddique, Ahmed A

    2017-06-01

    The use of limited transthoracic echocardiography (TTE) has been restricted in patients after cardiac surgery due to reported poor image quality. The authors hypothesized that the hemodynamic state could be evaluated in a high proportion of patients at repeated intervals after cardiac surgery. Prospective observational study. Tertiary university hospital. The study comprised 51 patients aged 18 years or older presenting for cardiac surgery. Patients underwent TTE before surgery and at 3 time points after cardiac surgery. Images were assessed offline using an image quality scoring system by 2 expert observers. Hemodynamic state was assessed using the iHeartScan protocol, and the primary endpoint was the proportion of limited TTE studies in which the hemodynamic state was interpretable at each of the 3 postoperative time points. Hemodynamic state interpretability varied over time and was highest before surgery (90%) and lowest on the first postoperative day (49%) (p<0.01). This variation in interpretability over time was reflected in all 3 transthoracic windows, ranging from 43% to 80% before surgery and from 2% to 35% on the first postoperative day (p<0.01). Image quality scores were highest with the apical window, ranging from 53% to 77% across time points, and lowest with the subcostal window, ranging from 4% to 70% across time points (p< 0.01). Hemodynamic state can be determined with TTE in a high proportion of cardiac surgery patients after extubation and removal of surgical drains. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Assessment of cardiovascular impairment in obese patients: Limitations and troubleshooting of available imaging tools.

    PubMed

    Gaudieri, V; Nappi, C; Acampa, W; Assante, R; Zampella, E; Magliulo, M; Petretta, M; Cuocolo, A

    The prevalence and severity of obesity have increased over recent decades, reaching worldwide epidemics. Obesity is associated to coronary artery disease and other risk factors, including hypertension, heart failure and atrial fibrillation, which are all increased in the setting of obesity. Several noninvasive cardiac imaging modalities, such as echocardiography, cardiac computed tomography, magnetic resonance and cardiac gated single-photon emission computed tomography, are available in assessing coronary artery disease and myocardial dysfunction. Yet, in patients with excess adiposity the diagnostic accuracy of these techniques may be limited due to some issues. In this review, we analyze challenges and possibilities to find the optimal cardiac imaging approach to obese population. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  8. Radiation dose management for pediatric cardiac computed tomography: a report from the Image Gently 'Have-A-Heart' campaign.

    PubMed

    Rigsby, Cynthia K; McKenney, Sarah E; Hill, Kevin D; Chelliah, Anjali; Einstein, Andrew J; Han, B Kelly; Robinson, Joshua D; Sammet, Christina L; Slesnick, Timothy C; Frush, Donald P

    2018-01-01

    Children with congenital or acquired heart disease can be exposed to relatively high lifetime cumulative doses of ionizing radiation from necessary medical imaging procedures including radiography, fluoroscopic procedures including diagnostic and interventional cardiac catheterizations, electrophysiology examinations, cardiac computed tomography (CT) studies, and nuclear cardiology examinations. Despite the clinical necessity of these imaging studies, the related ionizing radiation exposure could pose an increased lifetime attributable cancer risk. The Image Gently "Have-A-Heart" campaign is promoting the appropriate use of medical imaging studies in children with congenital or acquired heart disease while minimizing radiation exposure. The focus of this manuscript is to provide a comprehensive review of radiation dose management and CT performance in children with congenital or acquired heart disease.

  9. Noninvasive reconstruction of the three-dimensional ventricular activation sequence during pacing and ventricular tachycardia in the canine heart.

    PubMed

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2012-01-01

    Single-beat imaging of myocardial activation promises to aid in both cardiovascular research and clinical medicine. In the present study we validate a three-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of simultaneous 3D intracardiac mapping to assess its capability to localize endocardial and epicardial initiation sites and image global activation sequences during pacing and ventricular tachycardia (VT) in the canine heart. Body surface potentials were measured simultaneously with bipolar electrical recordings in a closed-chest condition in healthy canines. Computed tomography images were obtained after the mapping study to construct realistic geometry models. Data analysis was performed on paced rhythms and VTs induced by norepinephrine (NE). The noninvasively reconstructed activation sequence was in good agreement with the simultaneous measurements from 3D cardiac mapping with a correlation coefficient of 0.74 ± 0.06, a relative error of 0.29 ± 0.05, and a root mean square error of 9 ± 3 ms averaged over 460 paced beats and 96 ectopic beats including premature ventricular complexes, couplets, and nonsustained monomorphic VTs and polymorphic VTs. Endocardial and epicardial origins of paced beats were successfully predicted in 72% and 86% of cases, respectively, during left ventricular pacing. The NE-induced ectopic beats initiated in the subendocardium by a focal mechanism. Sites of initial activation were estimated to be ∼7 mm from the measured initiation sites for both the paced beats and ectopic beats. For the polymorphic VTs, beat-to-beat dynamic shifts of initiation site and activation pattern were characterized by the reconstruction. The present results suggest that 3DCEI can noninvasively image the 3D activation sequence and localize the origin of activation of paced beats and NE-induced VTs in the canine heart with good accuracy. This 3DCEI technique offers the potential to aid interventional therapeutic procedures for treating ventricular arrhythmias arising from epicardial or endocardial sites and to noninvasively assess the mechanisms of these arrhythmias.

  10. Noninvasive reconstruction of the three-dimensional ventricular activation sequence during pacing and ventricular tachycardia in the canine heart

    PubMed Central

    Han, Chengzong; Pogwizd, Steven M.; Killingsworth, Cheryl R.

    2012-01-01

    Single-beat imaging of myocardial activation promises to aid in both cardiovascular research and clinical medicine. In the present study we validate a three-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of simultaneous 3D intracardiac mapping to assess its capability to localize endocardial and epicardial initiation sites and image global activation sequences during pacing and ventricular tachycardia (VT) in the canine heart. Body surface potentials were measured simultaneously with bipolar electrical recordings in a closed-chest condition in healthy canines. Computed tomography images were obtained after the mapping study to construct realistic geometry models. Data analysis was performed on paced rhythms and VTs induced by norepinephrine (NE). The noninvasively reconstructed activation sequence was in good agreement with the simultaneous measurements from 3D cardiac mapping with a correlation coefficient of 0.74 ± 0.06, a relative error of 0.29 ± 0.05, and a root mean square error of 9 ± 3 ms averaged over 460 paced beats and 96 ectopic beats including premature ventricular complexes, couplets, and nonsustained monomorphic VTs and polymorphic VTs. Endocardial and epicardial origins of paced beats were successfully predicted in 72% and 86% of cases, respectively, during left ventricular pacing. The NE-induced ectopic beats initiated in the subendocardium by a focal mechanism. Sites of initial activation were estimated to be ∼7 mm from the measured initiation sites for both the paced beats and ectopic beats. For the polymorphic VTs, beat-to-beat dynamic shifts of initiation site and activation pattern were characterized by the reconstruction. The present results suggest that 3DCEI can noninvasively image the 3D activation sequence and localize the origin of activation of paced beats and NE-induced VTs in the canine heart with good accuracy. This 3DCEI technique offers the potential to aid interventional therapeutic procedures for treating ventricular arrhythmias arising from epicardial or endocardial sites and to noninvasively assess the mechanisms of these arrhythmias. PMID:21984548

  11. Cardiac magnetic resonance imaging for the diagnosis of coronary artery disease: an evidence-based analysis.

    PubMed

    2010-01-01

    In July 2009, the Medical Advisory Secretariat (MAS) began work on Non-Invasive Cardiac Imaging Technologies for the Diagnosis of Coronary Artery Disease (CAD), an evidence-based review of the literature surrounding different cardiac imaging modalities to ensure that appropriate technologies are accessed by patients suspected of having CAD. This project came about when the Health Services Branch at the Ministry of Health and Long-Term Care asked MAS to provide an evidentiary platform on effectiveness and cost-effectiveness of non-invasive cardiac imaging modalities.After an initial review of the strategy and consultation with experts, MAS identified five key non-invasive cardiac imaging technologies for the diagnosis of CAD. Evidence-based analyses have been prepared for each of these five imaging modalities: cardiac magnetic resonance imaging, single photon emission computed tomography, 64-slice computed tomographic angiography, stress echocardiography, and stress echocardiography with contrast. For each technology, an economic analysis was also completed (where appropriate). A summary decision analytic model was then developed to encapsulate the data from each of these reports (available on the OHTAC and MAS website).The Non-Invasive Cardiac Imaging Technologies for the Diagnosis of Coronary Artery Disease series is made up of the following reports, which can be publicly accessed at the MAS website at: www.health.gov.on.ca/mas or at www.health.gov.on.ca/english/providers/program/mas/mas_about.htmlSINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY FOR THE DIAGNOSIS OF CORONARY ARTERY DISEASE: An Evidence-Based AnalysisSTRESS ECHOCARDIOGRAPHY FOR THE DIAGNOSIS OF CORONARY ARTERY DISEASE: An Evidence-Based AnalysisSTRESS ECHOCARDIOGRAPHY WITH CONTRAST FOR THE DIAGNOSIS OF CORONARY ARTERY DISEASE: An Evidence-Based Analysis64-Slice Computed Tomographic Angiography for the Diagnosis of Coronary Artery Disease: An Evidence-Based AnalysisCARDIAC MAGNETIC RESONANCE IMAGING FOR THE DIAGNOSIS OF CORONARY ARTERY DISEASE: An Evidence-Based AnalysisPease note that two related evidence-based analyses of non-invasive cardiac imaging technologies for the assessment of myocardial viability are also available on the MAS website:POSITRON EMISSION TOMOGRAPHY FOR THE ASSESSMENT OF MYOCARDIAL VIABILITY: An Evidence-Based AnalysisMAGNETIC RESONANCE IMAGING FOR THE ASSESSMENT OF MYOCARDIAL VIABILITY: an Evidence-Based AnalysisThe Toronto Health Economics and Technology Assessment Collaborative has also produced an associated economic report entitled:The Relative Cost-effectiveness of Five Non-invasive Cardiac Imaging Technologies for Diagnosing Coronary Artery Disease in Ontario [Internet]. Available from: http://theta.utoronto.ca/reports/?id=7 OBJECTIVE: The objective of this analysis was to determine the diagnostic accuracy of cardiac magnetic resonance imaging (MRI) for the diagnosis of patients with known/suspected coronary artery disease (CAD) compared to coronary angiography. Stress cardiac MRI is a non-invasive, x-ray free imaging technique that takes approximately 30 to 45 minutes to complete and can be performed using to two different methods, a) perfusion imaging following a first pass of an intravenous bolus of gadolinium contrast, or b) wall motion imaging. Stress is induced pharmacologically with either dobutamine, dipyridamole, or adenosine, as physical exercise is difficult to perform within the magnet bore and often induces motion artifacts. Alternatives to stress cardiac perfusion MRI include stress single-photon emission computed tomography (SPECT) and stress echocardiography (ECHO). The advantage of cardiac MRI is that it does not pose the radiation burden associated with SPECT. During the same sitting, cardiac MRI can also assess left and right ventricular dimensions, viability, and cardiac mass. It may also mitigate the need for invasive diagnostic coronary angiography in patients with intermediate risk factors for CAD. EVIDENCE-BASED ANALYSIS: A literature search was performed on October 9, 2009 using OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, EMBASE, the Cumulative Index to Nursing & Allied Health Literature (CINAHL), the Cochrane Library, and the International Agency for Health Technology Assessment (INAHTA) for studies published from January 1, 2005 to October 9, 2008. Abstracts were reviewed by a single reviewer and, for those studies meeting the eligibility criteria, full-text articles were obtained. Reference lists were also examined for any relevant studies not identified through the search. Articles with unknown eligibility were reviewed with a second clinical epidemiologist and then a group of epidemiologists until consensus was established. The quality of evidence was assessed as high, moderate, low or very low according to GRADE methodology. Given the large amount of clinical heterogeneity of the articles meeting the inclusion criteria, as well as suggestions from an Expert Advisory Panel Meeting held on October 5, 2009, the inclusion criteria were revised to examine the effectiveness of cardiac MRI for the detection of CAD. Inclusion CriteriaExclusion CriteriaHeath technology assessments, systematic reviews, randomized controlled trials, observational studies≥20 adult patients enrolled.Published 2004-2009Licensed by Health CanadaFor diagnosis of CAD:Reference standard is coronary angiographySignificant CAD defined as ≥ 50% coronary stenosisPatients with suspected or known CADReported results by patient, not segmentNon-English studiesGrey literaturePlanar imagingMUGAPatients with recent MI (i.e., within 1 month)Patients with non-ischemic heart diseaseStudies done exclusively in special populations (e.g., women, diabetics) Sensitivity and specificityArea under the curve (AUC)Diagnostic odds ratio (DOR) SUMMARY OF FINDINGS: Stress cardiac MRI using perfusion analysis yielded a pooled sensitivity of 0.91 (95% CI: 0.89 to 0.92) and specificity of 0.79 (95% CI: 0.76 to 0.82) for the detection of CAD.Stress cardiac MRI using wall motion analysis yielded a pooled sensitivity of 0.81 (95% CI: 0.77 to 0.84) and specificity of 0.85 (95% CI: 0.81 to 0.89) for the detection of CAD.Based on DORs, there was no significant difference between pooled stress cardiac MRI using perfusion analysis and pooled stress cardiac MRI using wall motion analysis (P=0.26) for the detection of CAD.Pooled subgroup analysis of stress cardiac MRI using perfusion analysis showed no significant difference in the DORs between 1.5T and 3T MRI (P=0.72) for the detection of CAD.One study (N=60) was identified that examined stress cardiac MRI using wall motion analysis with a 3T MRI. The sensitivity and specificity of 3T MRI were 0.64 (95% CI: 0.44 to 0.81) and 1.00 (95% CI: 0.89 to 1.00), respectively, for the detection of CAD.The effectiveness of stress cardiac MRI for the detection of CAD in unstable patients with acute coronary syndrome was reported in only one study (N=35). Using perfusion analysis, the sensitivity and specificity were 0.72 (95% CI: 0.53 to 0.87) and 1.00 (95% CI: 0.54 to 1.00), respectively, for the detection of CAD. According to an expert consultant, in Ontario: Stress first pass perfusion is currently performed in small numbers in London (London Health Sciences Centre) and Toronto (University Health Network at the Toronto General Hospital site and Sunnybrook Health Sciences Centre).Stress wall motion is only performed as part of research protocols and not very often.Cardiac MRI machines use 1.5T almost exclusively, with 3T used in research for first pass perfusion.On November 25 2009, the Cardiac Imaging Expert Advisory Panel met and made the following comments about stress cardiac MRI for perfusion analysis: Accessibility to cardiac MRI is limited and generally used to assess structural abnormalities. Most MRIs in Ontario are already in 24-hour, constant use and it would thus be difficult to add cardiac MRI for CAD diagnosis as an additional indication.The performance of cardiac MRI for the diagnosis of CAD can be technically challenging. The quality of the body of evidence was assessed according to the GRADE Working Group criteria for diagnostic tests. For perfusion analysis, the overall quality was determined to be low and for wall motion analysis the overall quality was very low.

  12. Projection-based motion estimation for cardiac functional analysis with high temporal resolution: a proof-of-concept study with digital phantom experiment

    NASA Astrophysics Data System (ADS)

    Suzuki, Yuki; Fung, George S. K.; Shen, Zeyang; Otake, Yoshito; Lee, Okkyun; Ciuffo, Luisa; Ashikaga, Hiroshi; Sato, Yoshinobu; Taguchi, Katsuyuki

    2017-03-01

    Cardiac motion (or functional) analysis has shown promise not only for non-invasive diagnosis of cardiovascular diseases but also for prediction of cardiac future events. Current imaging modalities has limitations that could degrade the accuracy of the analysis indices. In this paper, we present a projection-based motion estimation method for x-ray CT that estimates cardiac motion with high spatio-temporal resolution using projection data and a reference 3D volume image. The experiment using a synthesized digital phantom showed promising results for motion analysis.

  13. A shot to the heart: a rare case of cardiac embolization

    PubMed Central

    Elsisi, Islam Fathi Hussein Ali; Kidambi, Ananth

    2018-01-01

    Summary This is a case report of intracardiac foreign bodies that gained access to the heart by migration from a peripheral vein. The case report describes the diagnostic findings on cardiac imaging and summarizes different approaches to management. Learning points: Appearance of embolized cardiac missiles with reverberation and acoustic shadowing. Role of different imaging modalities in the diagnosis of intracardiac foreign bodies. Indications for surgical or transcatheter retrieval. PMID:29440229

  14. Dynamic three-dimensional display of common congenital cardiac defects from reconstruction of two-dimensional echocardiographic images.

    PubMed

    Hsieh, K S; Lin, C C; Liu, W S; Chen, F L

    1996-01-01

    Two-dimensional echocardiography had long been a standard diagnostic modality for congenital heart disease. Further attempts of three-dimensional reconstruction using two-dimensional echocardiographic images to visualize stereotypic structure of cardiac lesions have been successful only recently. So far only very few studies have been done to display three-dimensional anatomy of the heart through two-dimensional image acquisition because such complex procedures were involved. This study introduced a recently developed image acquisition and processing system for dynamic three-dimensional visualization of various congenital cardiac lesions. From December 1994 to April 1995, 35 cases were selected in the Echo Laboratory here from about 3000 Echo examinations completed. Each image was acquired on-line with specially designed high resolution image grazmber with EKG and respiratory gating technique. Off-line image processing using a window-architectured interactive software package includes construction of 2-D ehcocardiographic pixel to 3-D "voxel" with conversion of orthogonal to rotatory axial system, interpolation, extraction of region of interest, segmentation, shading and, finally, 3D rendering. Three-dimensional anatomy of various congenital cardiac defects was shown, including four cases with ventricular septal defects, two cases with atrial septal defects, and two cases with aortic stenosis. Dynamic reconstruction of a "beating heart" is recorded as vedio tape with video interface. The potential application of 3D display of the reconstruction from 2D echocardiographic images for the diagnosis of various congenital heart defects has been shown. The 3D display was able to improve the diagnostic ability of echocardiography, and clear-cut display of the various congenital cardiac defects and vavular stenosis could be demonstrated. Reinforcement of current techniques will expand future application of 3D display of conventional 2D images.

  15. Diabetes mellitus: long-term prognostic value of whole-body MR imaging for the occurrence of cardiac and cerebrovascular events.

    PubMed

    Bamberg, Fabian; Parhofer, Klaus G; Lochner, Elena; Marcus, Roy P; Theisen, Daniel; Findeisen, Hannes M; Hoffmann, Udo; Schönberg, Stefan O; Schlett, Christopher L; Reiser, Maximilian F; Weckbach, Sabine

    2013-12-01

    To study the predictive value of whole-body magnetic resonance (MR) imaging for the occurrence of cardiac and cerebrovascular events in a cohort of patients with diabetes mellitus (DM). This HIPAA-compliant study was approved by the institutional review board. Informed consent was obtained from all patients before enrollment into the study. The authors followed up 65 patients with DM (types 1 and 2) who underwent a comprehensive, contrast material-enhanced whole-body MR imaging protocol, including brain, cardiac, and vascular sequences at baseline. Follow-up was performed by phone interview. The primary endpoint was a major adverse cardiac and cerebrovascular event (MACCE), which was defined as composite cardiac-cerebrovascular death, myocardial infarction, cerebrovascular event, or revascularization. MR images were assessed for the presence of systemic atherosclerotic vessel changes, white matter lesions, and myocardial changes. Kaplan-Meier survival and Cox regression analyses were performed to determine associations. Follow-up was completed in 61 patients (94%; median age, 67.5 years; 30 women [49%]; median follow-up, 70 months); 14 of the 61 patients (23%) experienced MACCE. Although normal whole-body MR imaging excluded MACCE during the follow-up period (0%; 95% confidence interval [CI]: 0%, 17%), any detectable ischemic and/or atherosclerotic changes at whole-body MR imaging (prevalence, 66%) conferred a cumulative event rate of 20% at 3 years and 35% at 6 years. Whole-body MR imaging summary estimate of disease was strongly predictive for MACCE (one increment of vessel score and each territory with atherosclerotic changes: hazard ratio, 13.2 [95% CI: 4.5, 40.1] and 3.9 [95% CI: 2.2, 7.5], respectively), also beyond clinical characteristics as well as individual cardiac or cerebrovascular MR findings. These initial data indicate that disease burden as assessed with whole-body MR imaging confers strong prognostic information in patients with DM. Online supplemental material is available for this article. © RSNA, 2013.

  16. Cardiac gating with a pulse oximeter for dual-energy imaging

    NASA Astrophysics Data System (ADS)

    Shkumat, N. A.; Siewerdsen, J. H.; Dhanantwari, A. C.; Williams, D. B.; Paul, N. S.; Yorkston, J.; Van Metter, R.

    2008-11-01

    The development and evaluation of a prototype cardiac gating system for double-shot dual-energy (DE) imaging is described. By acquiring both low- and high-kVp images during the resting phase of the cardiac cycle (diastole), heart misalignment between images can be reduced, thereby decreasing the magnitude of cardiac motion artifacts. For this initial implementation, a fingertip pulse oximeter was employed to measure the peripheral pulse waveform ('plethysmogram'), offering potential logistic, cost and workflow advantages compared to an electrocardiogram. A gating method was developed that accommodates temporal delays due to physiological pulse propagation, oximeter waveform processing and the imaging system (software, filter-wheel, anti-scatter Bucky-grid and flat-panel detector). Modeling the diastolic period allowed the calculation of an implemented delay, timp, required to trigger correctly during diastole at any patient heart rate (HR). The model suggests a triggering scheme characterized by two HR regimes, separated by a threshold, HRthresh. For rates at or below HRthresh, sufficient time exists to expose on the same heartbeat as the plethysmogram pulse [timp(HR) = 0]. Above HRthresh, a characteristic timp(HR) delays exposure to the subsequent heartbeat, accounting for all fixed and variable system delays. Performance was evaluated in terms of accuracy and precision of diastole-trigger coincidence and quantitative evaluation of artifact severity in gated and ungated DE images. Initial implementation indicated 85% accuracy in diastole-trigger coincidence. Through the identification of an improved HR estimation method (modified temporal smoothing of the oximeter waveform), trigger accuracy of 100% could be achieved with improved precision. To quantify the effect of the gating system on DE image quality, human observer tests were conducted to measure the magnitude of cardiac artifact under conditions of successful and unsuccessful diastolic gating. Six observers independently measured the artifact in 111 patient DE images. The data indicate that successful diastolic gating results in a statistically significant reduction (p < 0.001) in the magnitude of cardiac motion artifact, with residual artifact attributed primarily to gross patient motion.

  17. Acute effects of firefighting on cardiac performance.

    PubMed

    Fernhall, Bo; Fahs, Christopher A; Horn, Gavin; Rowland, Thomas; Smith, Denise

    2012-02-01

    This study examined standard echocardiographic measures of cardiac size and performance in response to a 3-h firefighting training exercise. Forty experienced male personnel completed a standardized 3 h live firefighting exercise. Before and after the firefighting activities, participants were weighed, height, heart rate, blood pressure and blood samples were obtained, and echocardiographic measurements were made. Firefighting produced significant decreases in left ventricular diastolic dimension, stroke volume, fractional shortening, and mitral E velocity, tachycardia, a rise in core temperature, and a reduction in calculated plasma volume. On tissue Doppler imaging, there were no changes in systolic contractile function, but a decreased lateral wall diastolic velocity was observed. These findings show that 3 h of live firefighting produced cardiac changes consistent with cardiac fatigue, coupled with a decrease in systemic arterial compliance. These data show that live firefighting produces significant cardiovascular changes and future work is needed to evaluate if these changes are related to the increase in cardiovascular risk during live firefighting.

  18. Myocardial ischaemia and cardiac pain – a mysterious relationship

    PubMed Central

    Fisher, Mike

    2013-01-01

    Pain related to cardiac disease has been recognised for centuries. However, the precise mechanisms of angina pectoris remain bafflingly obscure. Conventional cardiological angina management concentrates on methods to improve oxygen delivery to cardiac myocytes as our understanding of cardiac muscle cells’ response to hypoxia increases. In common with other chronic visceral pain syndromes, little is understood about how pain signals are generated and propagated by visceral nerves. Improved imaging and other physiological assessments have demonstrated important central nervous system (CNS) responses to myocardial ischaemia, including activation of CNS areas known to be ‘key players’ in chronic pain syndromes. Patients with stable angina usually have an excellent prognosis, especially if left ventricular function is preserved. Educating patients about their condition, teaching simple techniques known to help chronic pain patients and introducing targeted pain treatments specific to angina can be extremely helpful adjuncts to conventional cardiological treatments and will often bring about significant improvements in quality of life. PMID:26516494

  19. Integration of mechanical, structural and electrical imaging to understand response to cardiac resynchronization therapy.

    PubMed

    Silva, Etelvino; Bijnens, Bart; Berruezo, Antonio; Mont, Lluis; Doltra, Adelina; Andreu, David; Brugada, Josep; Sitges, Marta

    2014-10-01

    There is extensive controversy exists on whether cardiac resynchronization therapy corrects electrical or mechanical asynchrony. The aim of this study was to determine if there is a correlation between electrical and mechanical sequences and if myocardial scar has any relevant impact. Six patients with normal left ventricular function and 12 patients with left ventricular dysfunction and left bundle branch block, treated with cardiac resynchronization therapy, were studied. Real-time three-dimensional echocardiography and electroanatomical mapping were performed in all patients and, where applicable, before and after therapy. Magnetic resonance was performed for evaluation of myocardial scar. Images were postprocessed and mechanical and electrical activation sequences were defined and time differences between the first and last ventricular segment to be activated were determined. Response to therapy was defined as a reduction in left ventricular end-systolic volume ≥ 15% after 12 months of follow-up. Good correlation between electrical and mechanical timings was found in patients with normal left ventricular function (r(2) = 0.88; P = .005) but not in those with left ventricular dysfunction (r(2) = 0.02; P = not significant). After therapy, both timings and sequences were modified and improved, except in those with myocardial scar. Despite a close electromechanical relationship in normal left ventricular function, there is no significant correlation in patients with dysfunction. Although resynchronization therapy improves this correlation, the changes in electrical activation may not yield similar changes in left ventricular mechanics particularly depending on the underlying myocardial substrate. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  20. Non-invasive red light optogenetic pacing and optical coherence microscopy (OCM) imaging for drosophila melanogaster (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Men, Jing; Li, Airong; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2017-02-01

    Cardiac pacing could be a powerful tool for investigating mammalian cardiac electrical conduction systems as well as for treatment of certain cardiac pathologies. However, traditional electrical pacing using pacemaker requires an invasive surgical procedure. Electrical currents from the implanted electrodes can also cause damage to heart tissue, further restricting its utility. Optogenetic pacing has been developed as a promising, non-invasive alternative to electrical stimulation for controlling animal heart rhythms. It induces heart contractions by shining pulsed light on transgene-generated microbial opsins, which in turn activate the light gated ion channels in animal hearts. However, commonly used opsins in optogenetic pacing, such as channelrhodopsin-2 (ChR2), require short light wavelength stimulation (475 nm), which is strongly absorbed and scattered by tissue. Here, we performed optogenetic pacing by expression of recently engineered red-shifted microbial opsins, ReaChR and CsChrimson, in a well-established animal model, Drosophila melanogaster, using the 617 nm stimulation light pulses. The OCM technique enables non-invasive optical imaging of animal hearts with high speed and ultrahigh axial and transverse resolutions. We integrated a customized OCM system with the optical stimulation system to monitor the optogenetic pacing noninvasively. The use of red-sifted opsins enabled deeper penetration of simulating light at lower power, which is promising for applications of optogenetic pacing in mammalian cardiac pathology studies or clinical treatments in the future.

  1. Invasion of Peripheral Immune Cells into Brain Parenchyma after Cardiac Arrest and Resuscitation.

    PubMed

    Zhang, Can; Brandon, Nicole R; Koper, Kerryann; Tang, Pei; Xu, Yan; Dou, Huanyu

    2018-06-01

    Although a direct link has long been suspected between systemic immune responses and neuronal injuries after stroke, it is unclear which immune cells play an important role. A question remains as to whether the blood brain barrier (BBB) is transiently disrupted after circulatory arrest to allow peripheral immune cells to enter brain parenchyma. Here, we developed a clinically relevant cardiac arrest and resuscitation model in mice to investigate the BBB integrity using noninvasive magnetic resonance imaging. Changes in immune signals in the brain and periphery were assayed by immunohistochemistry and flow cytometry. Quantitative variance maps from T1-weighted difference images before and after blood-pool contrast clearance revealed BBB disruptions immediately after resuscitation and one day after reperfusion. Time profiles of hippocampal CA1 neuronal injuries correlated with the morphological changes of microglia activation. Cytotoxic T cells, CD11b + CD11c + dendritic cells, and CD11b + CD45 +hi monocytes and macrophages were significantly increased in the brain three days after cardiac arrest and resuscitation, suggesting direct infiltration of these cells following the BBB disruption. Importantly, these immune cell changes were coupled with a parallel increase in the same subset of immune cell populations in the bone marrow and blood. We conclude that neurovascular breakdown during the initial reperfusion phase contributes to the systemic immune cell invasion and subsequent neuropathogenesis affecting the long-term outcome after cardiac arrest and resuscitation.

  2. Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: Phantom and patient studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Chuan, E-mail: chuan.huang@stonybrookmedicine.edu; Department of Radiology, Harvard Medical School, Boston, Massachusetts 02115; Departments of Radiology, Psychiatry, Stony Brook Medicine, Stony Brook, New York 11794

    2015-02-15

    Purpose: Degradation of image quality caused by cardiac and respiratory motions hampers the diagnostic quality of cardiac PET. It has been shown that improved diagnostic accuracy of myocardial defect can be achieved by tagged MR (tMR) based PET motion correction using simultaneous PET-MR. However, one major hurdle for the adoption of tMR-based PET motion correction in the PET-MR routine is the long acquisition time needed for the collection of fully sampled tMR data. In this work, the authors propose an accelerated tMR acquisition strategy using parallel imaging and/or compressed sensing and assess the impact on the tMR-based motion corrected PETmore » using phantom and patient data. Methods: Fully sampled tMR data were acquired simultaneously with PET list-mode data on two simultaneous PET-MR scanners for a cardiac phantom and a patient. Parallel imaging and compressed sensing were retrospectively performed by GRAPPA and kt-FOCUSS algorithms with various acceleration factors. Motion fields were estimated using nonrigid B-spline image registration from both the accelerated and fully sampled tMR images. The motion fields were incorporated into a motion corrected ordered subset expectation maximization reconstruction algorithm with motion-dependent attenuation correction. Results: Although tMR acceleration introduced image artifacts into the tMR images for both phantom and patient data, motion corrected PET images yielded similar image quality as those obtained using the fully sampled tMR images for low to moderate acceleration factors (<4). Quantitative analysis of myocardial defect contrast over ten independent noise realizations showed similar results. It was further observed that although the image quality of the motion corrected PET images deteriorates for high acceleration factors, the images were still superior to the images reconstructed without motion correction. Conclusions: Accelerated tMR images obtained with more than 4 times acceleration can still provide relatively accurate motion fields and yield tMR-based motion corrected PET images with similar image quality as those reconstructed using fully sampled tMR data. The reduction of tMR acquisition time makes it more compatible with routine clinical cardiac PET-MR studies.« less

  3. Pre-clinical and Clinical Evaluation of High Resolution, Mobile Gamma Camera and Positron Imaging Devices

    DTIC Science & Technology

    2009-10-01

    Field-of-View, Mobile PET/SPECT System for Bedside Environments: A Dynamic Cardiac Phantom Study using 99mTc and 18F- FDG . Presented at the American...using Tc-99m tracers and viability imaging using F- 18 tracers [3]-[7]. For cardiac F-18 imaging in a bedside environment, the 511 keV SPECT approach...SPECT system may have difficulty imaging subtle myocardial defects with F-18 tracers , but it may effectively image moderate to severe defects. The

  4. 23-year experience on diagnosis and surgical treatment of benign and malignant cardiac tumors

    PubMed Central

    Jaszewski, Ryszard; Marcinkiewicz, Anna; Bartczak, Karol; Knopik, Jerzy; Ostrowski, Stanisław

    2013-01-01

    Introduction Although myxoma is the most frequent cardiac tumor, other conditions should be taken into consideration in the differential diagnosis. Transthoracic echocardiography (TTE), followed by transesophageal echocardiography (TEE) remain the principal methods for cardiac tumor screening and visualizing. The aim of the study was to compare the diagnostics, surgical treatment and prognosis of malignant and benign cardiac tumors. Material and methods From 1986 to 2009 there were 121 patients with cardiac tumors operated on in the Cardiac Surgery Clinic of the Medical University in Lodz. Patients were referred to surgery mainly on the basis of the TTE and TEE image. In 4 cases valvular prosthesis implantation or valve repair were carried out. Patients remained under long-term observation in the Cardiac Surgery Outpatient Clinic. Results Myxoma was diagnosed in 114 cases. Malignancies were discovered in 7 cases. The left atrium was the most frequent localization. The echocardiographic image differed significantly in benign and malignant tumors. The postoperative period was complicated by embolic events or myocardial infarctions. Only malignant tumors were associated with mortality due to cardiovascular events. The survival for malignant tumors was significantly shorter. Conclusions Short and long-term results of operative treatment are very good for benign tumors in contrast to cardiac malignancies. The TTE and TEE image can be very significant in the final diagnosis. PMID:24273564

  5. Comparison of simultaneous and sequential SPECT imaging for discrimination tasks in assessment of cardiac defects.

    PubMed

    Trott, C M; Ouyang, J; El Fakhri, G

    2010-11-21

    Simultaneous rest perfusion/fatty-acid metabolism studies have the potential to replace sequential rest/stress perfusion studies for the assessment of cardiac function. Simultaneous acquisition has the benefits of increased signal and lack of need for patient stress, but is complicated by cross-talk between the two radionuclide signals. We consider a simultaneous rest (99m)Tc-sestamibi/(123)I-BMIPP imaging protocol in place of the commonly used sequential rest/stress (99m)Tc-sestamibi protocol. The theoretical precision with which the severity of a cardiac defect and the transmural extent of infarct can be measured is computed for simultaneous and sequential SPECT imaging, and their performance is compared for discriminating (1) degrees of defect severity and (2) sub-endocardial from transmural defects. We consider cardiac infarcts for which reduced perfusion and metabolism are observed. From an information perspective, simultaneous imaging is found to yield comparable or improved performance compared with sequential imaging for discriminating both severity of defect and transmural extent of infarct, for three defects of differing location and size.

  6. Image quality improvement in MDCT cardiac imaging via SMART-RECON method

    NASA Astrophysics Data System (ADS)

    Li, Yinsheng; Cao, Ximiao; Xing, Zhanfeng; Sun, Xuguang; Hsieh, Jiang; Chen, Guang-Hong

    2017-03-01

    Coronary CT angiography (CCTA) is a challenging imaging task currently limited by the achievable temporal resolution of modern Multi-Detector CT (MDCT) scanners. In this paper, the recently proposed SMARTRECON method has been applied in MDCT-based CCTA imaging to improve the image quality without any prior knowledge of cardiac motion. After the prospective ECG-gated data acquisition from a short-scan angular span, the acquired data were sorted into several sub-sectors of view angles; each corresponds to a 1/4th of the short-scan angular range. Information of the cardiac motion was thus encoded into the data in each view angle sub-sector. The SMART-RECON algorithm was then applied to jointly reconstruct several image volumes, each of which is temporally consistent with the data acquired in the corresponding view angle sub-sector. Extensive numerical simulations were performed to validate the proposed technique and investigate the performance dependence.

  7. Embryonic stem cell grafting in normal and infarcted myocardium: serial assessment with MR imaging and PET dual detection.

    PubMed

    Qiao, Hui; Zhang, Hualei; Zheng, Yuanjie; Ponde, Datta E; Shen, Dinggang; Gao, Fabao; Bakken, Ashley B; Schmitz, Alexander; Kung, Hank F; Ferrari, Victor A; Zhou, Rong

    2009-03-01

    To use magnetic resonance (MR) imaging and positron emission tomography (PET) dual detection of cardiac-grafted embryonic stem cells (ESCs) to examine (a) survival and proliferation of ESCs in normal and infarcted myocardium, (b) host macrophage versus grafted ESC contribution to serial MR imaging signal over time, and (c) cardiac function associated with the formation of grafts and whether improvement in cardiac function is related to cardiac differentiation of ESCs. All animal procedures were approved by the institutional animal care and use committee. Murine ESCs were stably transfected with a mutant version of herpes simplex virus type 1 thymidine kinase, HSV1-sr39tk, and also were labeled with superparamagnetic iron oxide (SPIO) particles. Cells were injected directly in the border zone of the infarcted heart or in corresponding regions of normal hearts in athymic rats. PET and MR imaging were performed longitudinally for 4 weeks in the same animals. ESCs survived and underwent proliferation in the infarcted and normal hearts, as demonstrated by serial increases in 9-(4-[(18)F]fluoro-3-hydroxymethylbutyl) guanine PET signals. In parallel, the hypointense areas on MR images at the injection sites decreased over time. Double staining for host macrophages and SPIO particles revealed that the majority of SPIO-containing cells were macrophages at week 4 after injection. Left ventricular ejection fraction increased in the ESC-treated rats but decreased in culture media-treated rats, and border-zone function was preserved in ESC-treated animals; however, cardiac differentiation of ESCs was less than 0.5%. Dual-modality imaging permits complementary information in regard to cell survival and proliferation, graft formation, and effects on cardiac function. http://radiology.rsnajnls.org/cgi/content/full/250/3/821/DC1. RSNA, 2009

  8. Cardiac structure and function in Cushing's syndrome: a cardiac magnetic resonance imaging study.

    PubMed

    Kamenický, Peter; Redheuil, Alban; Roux, Charles; Salenave, Sylvie; Kachenoura, Nadjia; Raissouni, Zainab; Macron, Laurent; Guignat, Laurence; Jublanc, Christel; Azarine, Arshid; Brailly, Sylvie; Young, Jacques; Mousseaux, Elie; Chanson, Philippe

    2014-11-01

    Patients with Cushing's syndrome have left ventricular (LV) hypertrophy and dysfunction on echocardiography, but echo-based measurements may have limited accuracy in obese patients. No data are available on right ventricular (RV) and left atrial (LA) size and function in these patients. The objective of the study was to evaluate LV, RV, and LA structure and function in patients with Cushing's syndrome by means of cardiac magnetic resonance, currently the reference modality in assessment of cardiac geometry and function. Eighteen patients with active Cushing's syndrome and 18 volunteers matched for age, sex, and body mass index were studied by cardiac magnetic resonance. The imaging was repeated in the patients 6 months (range 2-12 mo) after the treatment of hypercortisolism. Compared with controls, patients with Cushing's syndrome had lower LV, RV, and LA ejection fractions (P < .001 for all) and increased end-diastolic LV segmental thickness (P < .001). Treatment of hypercortisolism was associated with an improvement in ventricular and atrial systolic performance, as reflected by a 15% increase in the LV ejection fraction (P = .029), a 45% increase in the LA ejection fraction (P < .001), and an 11% increase in the RV ejection fraction (P = NS). After treatment, the LV mass index and end-diastolic LV mass to volume ratio decreased by 17% (P < .001) and 10% (P = .002), respectively. None of the patients had late gadolinium myocardial enhancement. Cushing's syndrome is associated with subclinical biventricular and LA systolic dysfunctions that are reversible after treatment. Despite skeletal muscle atrophy, Cushing's syndrome patients have an increased LV mass, reversible upon correction of hypercortisolism.

  9. Alterations in apparent diffusion coefficient values of the kidney during the cardiac cycle: Evaluation with ECG-triggered diffusion-weighted MR imaging.

    PubMed

    Ito, Katsuyoshi; Hayashida, Minoru; Kanki, Akihiko; Yamamoto, Akira; Tamada, Tsutomu; Yoshida, Koji; Tanabe, Masahiro

    2018-05-17

    To evaluate dynamic changes in apparent diffusion coefficient (ADC) values of the kidney at different time points during the cardiac cycle using electrocardiographic (ECG)-triggered diffusion-weighted MR imaging in normal subjects, and to elucidate the differences in ADC values between the right and left kidneys during a cardiac cycle. The study was approved by our institutional review board and informed consent was obtained from subjects. Twenty healthy volunteers who underwent ECG-triggered diffusion-weighted MR imaging of the kidney were included. The differences in ADC values of each kidney during different cardiac phases were compared. Additionally, the differences in maximum and minimum ADC values between the right and left kidney were also evaluated. ADC values in the right and left kidney changed significantly during the cardiac cycle (P < 0.00001). Maximum and minimum ADC values during the cardiac cycle of the left kidney were significantly higher (P = 0.026 and 0.017, respectively) than those of the right kidney. Maximum ADC value in the left kidney had a significantly strong positive correlation with the left renal vein ratio (r = 0.83, P < 0.00001). In the right kidney, maximum ADC showed a weakly positive correlation with the diameter of the right renal vein (r = 0.45, P = 0.048). ADC values of the kidney obtained using ECG-triggered diffusion-weighted MR imaging change significantly during the cardiac cycle. Maximum (systolic) ADC during the cardiac cycle of the left kidney was significantly higher than that of the right kidney, probably due to the anatomical difference in the renal vein. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. WE-FG-202-06: The Use of Hybrid PET MRI for Identifying the Presence of Cardiac Inflammation Following External Beam Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    El-Sherif, O; Xhaferllari, I; Battista, J

    Purpose: To monitor the evolution of radiation-induced cardiac inflammation in a canine model using hybrid positron emission tomography (PET/magnetic resonance imaging (MRI). Methods: Research ethics approval was obtained for a longitudinal imaging study of 5 canines after cardiac irradiation. Animals were imaged at baseline, 3 months, 6 months, and 12 months post cardiac irradiation using a hybrid PET-MRI system (Biograph mMR, Siemens Healthcare). The imaging protocol was designed to assess changes in cardiac inflammation using {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) PET tracer. In order to image cardiac inflammation, the normal myocardial uptake of glucose was suppressed prior to the injection ofmore » {sup 18}F-FDG. The suppression of glycolysis was achieved through; fasting (16–21 hours prior to the start of imaging) and an intravenous injection of heparin immediately followed by a 20% lipid infusion 20 min prior to the injection of {sup 18}F-FDG. The standard uptake value (SUV) obtained from 17 myocardial regions were used to compare FDG scans. All animals received a simulation CT scan (GE Medical Systems) for radiation treatment planning. Radiation treatment plans were created using the Pinncale3 treatment planning system (Philips Radiation Oncology Systems) and designed to resemble the typical cardiac exposure during left-sided breast cancer radiotherapy. Cardiac irradiations were performed in a single fraction using a TrueBeam linear accelerator (Varian Medical Systems). Results: The delivered dose (mean ± standard error) to heart, left ventricle, and left anterior descending artery were 1.7±0.1 Gy, 2.7±0.1 Gy, and 5.5±0.3 Gy respectively. At these doses, a significant increase in {sup 18}F-FDG uptake within the entire heart relative to baseline (1.1±0.02 g/ml) uptake was observed. {sup 18}F-FDG uptake at 3 months, 6 months, and 12 months post irradiation were 1.8±0.03 g/ml, 2.4±0.06 g/ml, and 2.6±0.11 g/ml respectively. Conclusion: Low doses of limited cardiac irradiation show evidence of a persistent global inflammatory response that can be detected using {sup 18}F-FDG PET imaging. This work was supported through the Translational Breast Cancer Studentship award, funded in part by the Breast Cancer Society of Canada. Additional financial support is provided by the London Regional Cancer Program Catalyst Grant and the Thames Valley Veterinary Services.« less

  11. Cardiac Light-Sheet Fluorescent Microscopy for Multi-Scale and Rapid Imaging of Architecture and Function

    NASA Astrophysics Data System (ADS)

    Fei, Peng; Lee, Juhyun; Packard, René R. Sevag; Sereti, Konstantina-Ioanna; Xu, Hao; Ma, Jianguo; Ding, Yichen; Kang, Hanul; Chen, Harrison; Sung, Kevin; Kulkarni, Rajan; Ardehali, Reza; Kuo, C.-C. Jay; Xu, Xiaolei; Ho, Chih-Ming; Hsiai, Tzung K.

    2016-03-01

    Light Sheet Fluorescence Microscopy (LSFM) enables multi-dimensional and multi-scale imaging via illuminating specimens with a separate thin sheet of laser. It allows rapid plane illumination for reduced photo-damage and superior axial resolution and contrast. We hereby demonstrate cardiac LSFM (c-LSFM) imaging to assess the functional architecture of zebrafish embryos with a retrospective cardiac synchronization algorithm for four-dimensional reconstruction (3-D space + time). By combining our approach with tissue clearing techniques, we reveal the entire cardiac structures and hypertrabeculation of adult zebrafish hearts in response to doxorubicin treatment. By integrating the resolution enhancement technique with c-LSFM to increase the resolving power under a large field-of-view, we demonstrate the use of low power objective to resolve the entire architecture of large-scale neonatal mouse hearts, revealing the helical orientation of individual myocardial fibers. Therefore, our c-LSFM imaging approach provides multi-scale visualization of architecture and function to drive cardiovascular research with translational implication in congenital heart diseases.

  12. Non-invasive electromechanical activation imaging as a tool to study left ventricular dyssynchronous patients: Implication for CRT therapy.

    PubMed

    Dawoud, Fady; Spragg, David D; Berger, Ronald D; Cheng, Alan; Horáček, B Milan; Halperin, Henry R; Lardo, Albert C

    2016-01-01

    Electromechanical de-coupling is hypothesized to explain non-response of dyssynchrony patient to cardiac resynchronization therapy (CRT). In this pilot study, we investigated regional electromechanical uncoupling in 10 patients referred for CRT using two non-invasive electrical and mechanical imaging techniques (CMR tissue tracking and ECGI). Reconstructed regional electrical and mechanical activation captured delayed LBBB propagation direction from septal to anterior/inferior and finally to lateral walls as well as from LV apical to basal. All 5 responders demonstrated significantly delayed mechanical and electrical activation on the lateral LV wall at baseline compared to the non-responders (P<.05). On follow-up ECGI, baseline electrical activation patterns were preserved in native rhythm and global LV activation time was reduced with biventricular pacing. The combination of novel imaging techniques of ECGI and CMR tissue tracking can be used to assess spatial concordance of LV electrical and mechanical activation to gain insight into electromechanical coupling. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Interdepartmental conflict management and negotiation in cardiovascular imaging.

    PubMed

    Otero, Hansel J; Nallamshetty, Leelakrishna; Rybicki, Frank J

    2008-07-01

    Although the relationship between cardiologists and radiologists has a thorny history, advanced cardiac imaging technology and the promise of cardiac computed tomography are forcing both specialties back to the negotiation table. These discussions represent an opportunity for better communication, collaboration, and resource allocation. The authors address the aspects of interdepartmental conflict management and negotiation through their radiology department's ongoing efforts to provide high-quality advanced noninvasive cardiovascular imaging services at a large academic institution. The definition and causes of conflict are defined, with a specific focus on noninvasive cardiovascular imaging, followed by a description of steps used in the negotiation process. The authors encourage radiologists to entertain an open dialogue with cardiology, because in many cases, both sides can benefit. The benefits of a negotiated outcome include minimizing internal competitors, incorporating cardiologists' expertise to cardiac imaging algorithms, and more effective training opportunities.

  14. 3D/2D model-to-image registration by imitation learning for cardiac procedures.

    PubMed

    Toth, Daniel; Miao, Shun; Kurzendorfer, Tanja; Rinaldi, Christopher A; Liao, Rui; Mansi, Tommaso; Rhode, Kawal; Mountney, Peter

    2018-05-12

    In cardiac interventions, such as cardiac resynchronization therapy (CRT), image guidance can be enhanced by involving preoperative models. Multimodality 3D/2D registration for image guidance, however, remains a significant research challenge for fundamentally different image data, i.e., MR to X-ray. Registration methods must account for differences in intensity, contrast levels, resolution, dimensionality, field of view. Furthermore, same anatomical structures may not be visible in both modalities. Current approaches have focused on developing modality-specific solutions for individual clinical use cases, by introducing constraints, or identifying cross-modality information manually. Machine learning approaches have the potential to create more general registration platforms. However, training image to image methods would require large multimodal datasets and ground truth for each target application. This paper proposes a model-to-image registration approach instead, because it is common in image-guided interventions to create anatomical models for diagnosis, planning or guidance prior to procedures. An imitation learning-based method, trained on 702 datasets, is used to register preoperative models to intraoperative X-ray images. Accuracy is demonstrated on cardiac models and artificial X-rays generated from CTs. The registration error was [Formula: see text] on 1000 test cases, superior to that of manual ([Formula: see text]) and gradient-based ([Formula: see text]) registration. High robustness is shown in 19 clinical CRT cases. Besides the proposed methods feasibility in a clinical environment, evaluation has shown good accuracy and high robustness indicating that it could be applied in image-guided interventions.

  15. Semi-automated scar detection in delayed enhanced cardiac magnetic resonance images

    NASA Astrophysics Data System (ADS)

    Morisi, Rita; Donini, Bruno; Lanconelli, Nico; Rosengarden, James; Morgan, John; Harden, Stephen; Curzen, Nick

    2015-06-01

    Late enhancement cardiac magnetic resonance images (MRI) has the ability to precisely delineate myocardial scars. We present a semi-automated method for detecting scars in cardiac MRI. This model has the potential to improve routine clinical practice since quantification is not currently offered due to time constraints. A first segmentation step was developed for extracting the target regions for potential scar and determining pre-candidate objects. Pattern recognition methods are then applied to the segmented images in order to detect the position of the myocardial scar. The database of late gadolinium enhancement (LE) cardiac MR images consists of 111 blocks of images acquired from 63 patients at the University Hospital Southampton NHS Foundation Trust (UK). At least one scar was present for each patient, and all the scars were manually annotated by an expert. A group of images (around one third of the entire set) was used for training the system which was subsequently tested on all the remaining images. Four different classifiers were trained (Support Vector Machine (SVM), k-nearest neighbor (KNN), Bayesian and feed-forward neural network) and their performance was evaluated by using Free response Receiver Operating Characteristic (FROC) analysis. Feature selection was implemented for analyzing the importance of the various features. The segmentation method proposed allowed the region affected by the scar to be extracted correctly in 96% of the blocks of images. The SVM was shown to be the best classifier for our task, and our system reached an overall sensitivity of 80% with less than 7 false positives per patient. The method we present provides an effective tool for detection of scars on cardiac MRI. This may be of value in clinical practice by permitting routine reporting of scar quantification.

  16. Enhancing ejection fraction measurement through 4D respiratory motion compensation in cardiac PET imaging

    NASA Astrophysics Data System (ADS)

    Tang, Jing; Wang, Xinhui; Gao, Xiangzhen; Segars, W. Paul; Lodge, Martin A.; Rahmim, Arman

    2017-06-01

    ECG gated cardiac PET imaging measures functional parameters such as left ventricle (LV) ejection fraction (EF), providing diagnostic and prognostic information for management of patients with coronary artery disease (CAD). Respiratory motion degrades spatial resolution and affects the accuracy in measuring the LV volumes for EF calculation. The goal of this study is to systematically investigate the effect of respiratory motion correction on the estimation of end-diastolic volume (EDV), end-systolic volume (ESV), and EF, especially on the separation of normal and abnormal EFs. We developed a respiratory motion incorporated 4D PET image reconstruction technique which uses all gated-frame data to acquire a motion-suppressed image. Using the standard XCAT phantom and two individual-specific volunteer XCAT phantoms, we simulated dual-gated myocardial perfusion imaging data for normally and abnormally beating hearts. With and without respiratory motion correction, we measured the EDV, ESV, and EF from the cardiac-gated reconstructed images. For all the phantoms, the estimated volumes increased and the biases significantly reduced with motion correction compared with those without. Furthermore, the improvement of ESV measurement in the abnormally beating heart led to better separation of normal and abnormal EFs. The simulation study demonstrated the significant effect of respiratory motion correction on cardiac imaging data with motion amplitude as small as 0.7 cm. The larger the motion amplitude the more improvement respiratory motion correction brought about on the EF measurement. Using data-driven respiratory gating, we also demonstrated the effect of respiratory motion correction on estimating the above functional parameters from list mode patient data. Respiratory motion correction has been shown to improve the accuracy of EF measurement in clinical cardiac PET imaging.

  17. Cardio-chemical exchange saturation transfer magnetic resonance imaging reveals molecular signatures of endogenous fibrosis and exogenous contrast media.

    PubMed

    Vandsburger, Moriel; Vandoorne, Katrien; Oren, Roni; Leftin, Avigdor; Mpofu, Senzeni; Delli Castelli, Daniela; Aime, Silvio; Neeman, Michal

    2015-01-01

    Application of emerging molecular MRI techniques, including chemical exchange saturation transfer (CEST)-MRI, to cardiac imaging is desirable; however, conventional methods are poorly suited for cardiac imaging, particularly in small animals with rapid heart rates. We developed a CEST-encoded steady state and retrospectively gated cardiac cine imaging sequence in which the presence of fibrosis or paraCEST contrast agents was directly encoded into the steady-state myocardial signal intensity (cardioCEST). Development of cardioCEST: A CEST-encoded cardiac cine MRI sequence was implemented on a 9.4T small animal scanner. CardioCEST of fibrosis was serially performed by acquisition of a series of CEST-encoded cine images at multiple offset frequencies in mice (n=7) after surgically induced myocardial infarction. Scar formation was quantified using a spectral modeling approach and confirmed with histological staining. Separately, circulatory redistribution kinetics of the paramagnetic CEST agent Eu-HPDO3A were probed in mice using cardioCEST imaging, revealing rapid myocardial redistribution, and washout within 30 minutes (n=6). Manipulation of vascular tone resulted in heightened peak CEST contrast in the heart, but did not alter redistribution kinetics (n=6). At 28 days after myocardial infarction (n=3), CEST contrast kinetics in infarct zone tissue were altered, demonstrating gradual accumulation of Eu-HPDO3A in the increased extracellular space. cardioCEST MRI enables in vivo imaging of myocardial fibrosis using endogenous contrast mechanisms, and of exogenously delivered paraCEST agents, and can enable multiplexed imaging of multiple molecular targets at high-resolution coupled with conventional cardiac MRI scans. © 2013 American Heart Association, Inc.

  18. Combining clinical and thallium data optimizes preoperative assessment of cardiac risk before major vascular surgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eagle, K.A.; Coley, C.M.; Newell, J.B.

    1989-06-01

    STUDY OBJECTIVE: To determine whether clinical markers and preoperative dipyridamole-thallium imaging are both useful in predicting ischemic events after vascular surgery. Two hundred fifty-four consecutive patients were referred to a nuclear cardiology laboratory before surgery. Forty-four patients had surgery cancelled or postponed after clinical evaluation and dipyridamole-thallium imaging. Surgery was not confirmed for ten. Two hundred patients receiving prompt vascular surgery were the study group. Thirty patients (15%) had early postoperative cardiac ischemic events, with cardiac death in 6 (3%) and nonfatal myocardial infarction in 9 (4.5%). Logistic regression identified five clinical predictors (Q waves, history of ventricular ectopic activity,more » diabetes, advanced age, angina) and two dipyridamole-thallium predictors of postoperative events. Of patients with none of the clinical variables (n = 64), only 2 (3.1%; 95% CI, 0% to 8%) had ischemic events with no cardiac deaths. Ten of twenty (50%; 95% CI, 29% to 71%) patients with three or more clinical markers had events. Eighteen of one hundred sixteen (15.5%; 95% CI, 7% to 21%) patients with either 1 or 2 clinical predictors had events. Within this group, 2 of 62 (3.2%; 95% CI, 0% to 8%) patients without thallium redistribution had events compared with 16 events in 54 patients (29.6%; 95% CI, 16% to 44%) with thallium redistribution. The multivariate model using both clinical and thallium variables showed significantly higher specificity at equivalent sensitivity levels than models using either clinical or thallium variables alone. Preoperative dipyridamole-thallium imaging appears most useful to stratify vascular patients determined to be at intermediate risk by clinical evaluation.« less

  19. Normal and Pathological NCAT Image and PhantomData Based onPhysiologically Realistic Left Ventricle Finite-Element Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veress, Alexander I.; Segars, W. Paul; Weiss, Jeffrey A.

    2006-08-02

    The 4D NURBS-based Cardiac-Torso (NCAT) phantom, whichprovides a realistic model of the normal human anatomy and cardiac andrespiratory motions, is used in medical imaging research to evaluate andimprove imaging devices and techniques, especially dynamic cardiacapplications. One limitation of the phantom is that it lacks the abilityto accurately simulate altered functions of the heart that result fromcardiac pathologies such as coronary artery disease (CAD). The goal ofthis work was to enhance the 4D NCAT phantom by incorporating aphysiologically based, finite-element (FE) mechanical model of the leftventricle (LV) to simulate both normal and abnormal cardiac motions. Thegeometry of the FE mechanical modelmore » was based on gated high-resolutionx-ray multi-slice computed tomography (MSCT) data of a healthy malesubject. The myocardial wall was represented as transversely isotropichyperelastic material, with the fiber angle varying from -90 degrees atthe epicardial surface, through 0 degreesat the mid-wall, to 90 degreesat the endocardial surface. A time varying elastance model was used tosimulate fiber contraction, and physiological intraventricular systolicpressure-time curves were applied to simulate the cardiac motion over theentire cardiac cycle. To demonstrate the ability of the FE mechanicalmodel to accurately simulate the normal cardiac motion as well abnormalmotions indicative of CAD, a normal case and two pathologic cases weresimulated and analyzed. In the first pathologic model, a subendocardialanterior ischemic region was defined. A second model was created with atransmural ischemic region defined in the same location. The FE baseddeformations were incorporated into the 4D NCAT cardiac model through thecontrol points that define the cardiac structures in the phantom whichwere set to move according to the predictions of the mechanical model. Asimulation study was performed using the FE-NCAT combination toinvestigate how the differences in contractile function between thesubendocardial and transmural infarcts manifest themselves in myocardialSPECT images. The normal FE model produced strain distributions that wereconsistent with those reported in the literature and a motion consistentwith that defined in the normal 4D NCAT beating heart model based ontagged MRI data. The addition of a subendocardial ischemic region changedthe average transmural circumferential strain from a contractile value of0.19 to a tensile value of 0.03. The addition of a transmural ischemicregion changed average circumferential strain to a value of 0.16, whichis consistent with data reported in the literature. Model resultsdemonstrated differences in contractile function between subendocardialand transmural infarcts and how these differences in function aredocumented in simulated myocardial SPECT images produced using the 4DNCAT phantom. In comparison to the original NCAT beating heart model, theFE mechanical model produced a more accurate simulation for the cardiacmotion abnormalities. Such a model, when incorporated into the 4D NCATphantom, has great potential for use in cardiac imaging research. Withits enhanced physiologically-based cardiac model, the 4D NCAT phantom canbe used to simulate realistic, predictive imaging data of a patientpopulation with varying whole-body anatomy and with varying healthy anddiseased states of the heart that will provide a known truth from whichto evaluate and improve existing and emerging 4D imaging techniques usedin the diagnosis of cardiac disease.« less

  20. Imaging of Myocardial Fatty Acid Oxidation

    PubMed Central

    Mather, Kieren J; DeGrado, Tim

    2016-01-01

    Myocardial fuel selection is a key feature of the health and function of the heart, with clear links between myocardial function and fuel selection and important impacts of fuel selection on ischemia tolerance. Radiopharmaceuticals provide uniquely valuable tools for in vivo, non-invasive assessment of these aspects of cardiac function and metabolism. Here we review the landscape of imaging probes developed to provide noninvasive assessment of myocardial fatty acid oxidation (MFAO). Also, we review the state of current knowledge that myocardial fatty acid imaging has helped establish of static and dynamic fuel selection that characterizes cardiac and cardiometabolic disease and the interplay between fuel selection and various aspects of cardiac function. PMID:26923433

  1. Assessment of phase based dose modulation for improved dose efficiency in cardiac CT on an anthropomorphic motion phantom

    NASA Astrophysics Data System (ADS)

    Budde, Adam; Nilsen, Roy; Nett, Brian

    2014-03-01

    State of the art automatic exposure control modulates the tube current across view angle and Z based on patient anatomy for use in axial full scan reconstructions. Cardiac CT, however, uses a fundamentally different image reconstruction that applies a temporal weighting to reduce motion artifacts. This paper describes a phase based mA modulation that goes beyond axial and ECG modulation; it uses knowledge of the temporal view weighting applied within the reconstruction algorithm to improve dose efficiency in cardiac CT scanning. Using physical phantoms and synthetic noise emulation, we measure how knowledge of sinogram temporal weighting and the prescribed cardiac phase can be used to improve dose efficiency. First, we validated that a synthetic CT noise emulation method produced realistic image noise. Next, we used the CT noise emulation method to simulate mA modulation on scans of a physical anthropomorphic phantom where a motion profile corresponding to a heart rate of 60 beats per minute was used. The CT noise emulation method matched noise to lower dose scans across the image within 1.5% relative error. Using this noise emulation method to simulate modulating the mA while keeping the total dose constant, the image variance was reduced by an average of 11.9% on a scan with 50 msec padding, demonstrating improved dose efficiency. Radiation dose reduction in cardiac CT can be achieved while maintaining the same level of image noise through phase based dose modulation that incorporates knowledge of the cardiac reconstruction algorithm.

  2. Outcomes of surgical intervention for anomalous aortic origin of a coronary artery: A large contemporary prospective cohort study.

    PubMed

    Mery, Carlos M; De León, Luis E; Molossi, Silvana; Sexson-Tejtel, S Kristen; Agrawal, Hitesh; Krishnamurthy, Rajesh; Masand, Prakash; Qureshi, Athar M; McKenzie, E Dean; Fraser, Charles D

    2018-01-01

    The purpose of this study was to prospectively analyze the outcomes of patients with anomalous aortic origin of a coronary artery undergoing surgical intervention according to a standardized management algorithm. All patients aged 2 to 18 years undergoing surgical intervention for anomalous aortic origin of a coronary artery between December 2012 and April 2017 were prospectively included. Patients underwent stress nuclear perfusion imaging, stress cardiac magnetic resonance imaging, and retrospectively electrocardiogram-gated computed tomography angiography preoperatively. Patients were cleared for exercise at 3 months postoperatively if asymptomatic and repeat stress nuclear perfusion imaging, stress cardiac magnetic resonance imaging, and computed tomography angiography showed normal results. A total of 44 patients, with a median age of 14 years (8-18 years), underwent surgical intervention: 9 (20%) for the anomalous left coronary artery and 35 (80%) for the anomalous right coronary artery. Surgical procedures included unroofing in 35 patients (80%), translocation in 7 patients (16%), ostioplasty in 1 patient (2%), and side-side-anastomosis in 1 patient (2%). One patient who presented with aborted sudden cardiac death from an anomalous left coronary and underwent unroofing presented 1 year later with a recurrent episode and was found to have an unrecognized myocardial bridge and persistent compression of the coronary requiring reintervention. At last follow-up, 40 patients (91%) are asymptomatic and 4 patients have nonspecific chest pain; 42 patients (95%) have returned to full activity, and 2 patients are awaiting clearance. Surgical treatment for anomalous aortic origin of a coronary artery is safe and should aim to associate the coronary ostium with the correct sinus, away from the intercoronary pillar. After surgery, the majority of patients are cleared for exercise and remain asymptomatic. Longer follow-up is needed to assess the true efficacy of surgery in the prevention of sudden cardiac death. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  3. Sleep-disordered breathing, impaired cardiac adrenergic innervation and prognosis in heart failure.

    PubMed

    Scala, Oriana; Paolillo, Stefania; Formisano, Roberto; Pellegrino, Teresa; Rengo, Giuseppe; Gargiulo, Paola; De Michele, Fausto; Starace, Antonio; Rapacciuolo, Antonio; Parisi, Valentina; Prastaro, Maria; Piscopo, Valentina; Dellegrottaglie, Santo; Bruzzese, Dario; De Martino, Fabiana; Parente, Antonio; Leosco, Dario; Trimarco, Bruno; Cuocolo, Alberto; Perrone-Filardi, Pasquale

    2016-06-23

    Unfavourable effects of sleep-disordered breathing (SDB) in heart failure (HF) are mainly mediated by impaired sympathetic activity. Few data are available on SDB and cardiac adrenergic impairment evaluated at myocardial level. The aim of the study was to assess the relationship between SDB, cardiac sympathetic innervation assessed by 123 I-metaiodobenzylguanidine ( 123 I-MIBG) imaging and prognosis in HF. Observational, prospective study enrolling patients with HF and reduced systolic function. Patients underwent nocturnal cardiorespiratory monitoring to assess SDB presence by apnoea/hypopnoea index (AHI), and 123 I-MIBG imaging to calculate heart-to-mediastinum (H/M) ratios and washout rate. Patients were prospectively followed for 29±18 months for the combined endpoint of cardiovascular death and HF hospitalisation. Ninety-four patients (66.1±9.8 years; left ventricular ejection fraction 32±7%) were enrolled; 72 (77%) showed SDB and, compared with non-SDB, significantly reduced early (1.67±0.22 vs 1.77±0.13; p=0.019) and late H/M ratios (1.50±0.22 vs 1.61±0.23; p=0.038). Dividing patients into two groups according to SDB severity, patients with a moderate-severe disturbance (AHI >15; n=43) showed significantly worse survival for the composite study outcome (log-rank test, p=0.001) with respect to patients with mild or no disorder (AHI ≤15; n=51). Adding SDB variables to the already known prognostic role of 123 I-MIBG imaging, we observed a worse survival in patients with both SDB and H/M impairment. Patients with systolic HF and SDB show more impaired cardiac adrenergic innervation assessed by 123 I-MIBG imaging, and more adverse prognosis compared with HF patients without SDB. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  4. Dual regression physiological modeling of resting-state EPI power spectra: Effects of healthy aging.

    PubMed

    Viessmann, Olivia; Möller, Harald E; Jezzard, Peter

    2018-02-02

    Aging and disease-related changes in the arteriovasculature have been linked to elevated levels of cardiac cycle-induced pulsatility in the cerebral microcirculation. Functional magnetic resonance imaging (fMRI), acquired fast enough to unalias the cardiac frequency contributions, can be used to study these physiological signals in the brain. Here, we propose an iterative dual regression analysis in the frequency domain to model single voxel power spectra of echo planar imaging (EPI) data using external recordings of the cardiac and respiratory cycles as input. We further show that a data-driven variant, without external physiological traces, produces comparable results. We use this framework to map and quantify cardiac and respiratory contributions in healthy aging. We found a significant increase in the spatial extent of cardiac modulated white matter voxels with age, whereas the overall strength of cardiac-related EPI power did not show an age effect. Copyright © 2018. Published by Elsevier Inc.

  5. Interventricular membranous septal aneurysm: CT and MR manifestations.

    PubMed

    Carcano, Carolina; Kanne, Jeffrey P; Kirsch, Jacobo

    2016-02-01

    Advanced cardiac imaging is a valuable method to investigate cardiac malformations. The detection of the interventricular membranous septum has clinical significance due to thrombogenic and arrythmogenic predisposition, as well as a role in obstructing the pulmonary flow. This review describes six clinical presentations in which advanced cardiac imaging has been the tool for evaluation, with special emphasis in CT angiography and cardiac MRI sequences. Teaching Points • The interventricular membranous septum can predispose patients to thrombogenic and arrythmogenic events. • Subpulmonic stenosis relates to the protrusion of the aneurysm into the right ventricle • During surgery, ventricular pressures of the opened heart become balanced, making the aneurysm less evident.

  6. Real-time myocardium segmentation for the assessment of cardiac function variation

    NASA Astrophysics Data System (ADS)

    Zoehrer, Fabian; Huellebrand, Markus; Chitiboi, Teodora; Oechtering, Thekla; Sieren, Malte; Frahm, Jens; Hahn, Horst K.; Hennemuth, Anja

    2017-03-01

    Recent developments in MRI enable the acquisition of image sequences with high spatio-temporal resolution. Cardiac motion can be captured without gating and triggering. Image size and contrast relations differ from conventional cardiac MRI cine sequences requiring new adapted analysis methods. We suggest a novel segmentation approach utilizing contrast invariant polar scanning techniques. It has been tested with 20 datasets of arrhythmia patients. The results do not differ significantly more between automatic and manual segmentations than between observers. This indicates that the presented solution could enable clinical applications of real-time MRI for the examination of arrhythmic cardiac motion in the future.

  7. Optogenetic pacing in Drosophila melanogaster

    PubMed Central

    Alex, Aneesh; Li, Airong; Tanzi, Rudolph E.; Zhou, Chao

    2015-01-01

    Electrical stimulation is currently the gold standard for cardiac pacing. However, it is invasive and nonspecific for cardiac tissues. We recently developed a noninvasive cardiac pacing technique using optogenetic tools, which are widely used in neuroscience. Optogenetic pacing of the heart provides high spatial and temporal precisions, is specific for cardiac tissues, avoids artifacts associated with electrical stimulation, and therefore promises to be a powerful tool in basic cardiac research. We demonstrated optogenetic control of heart rhythm in a well-established model organism, Drosophila melanogaster. We developed transgenic flies expressing a light-gated cation channel, channelrhodopsin-2 (ChR2), specifically in their hearts and demonstrated successful optogenetic pacing of ChR2-expressing Drosophila at different developmental stages, including the larva, pupa, and adult stages. A high-speed and ultrahigh-resolution optical coherence microscopy imaging system that is capable of providing images at a rate of 130 frames/s with axial and transverse resolutions of 1.5 and 3.9 μm, respectively, was used to noninvasively monitor Drosophila cardiac function and its response to pacing stimulation. The development of a noninvasive integrated optical pacing and imaging system provides a novel platform for performing research studies in developmental cardiology. PMID:26601299

  8. Renin-Angiotensin System Blockade Improves Cardiac Indices in Acromegaly Patients.

    PubMed

    Thomas, Julia D J; Dattani, Abhishek; Zemrak, Filip; Burchell, Thomas; Akker, Scott A; Kaplan, Felicity J L; Khoo, Bernard; Aylwin, Simon; Grossman, Ashley B; Davies, L Ceri; Korbonits, Márta

    2017-06-01

    Blockade of the angiotensin-renin system, with angiotensin converting enzyme inhibitors (ACEi) and angiotensin receptor blockers (ARBs), has been shown to improve cardiac outcomes following myocardial infarction and delay progression of heart failure. Acromegaly is associated with a disease-specific cardiomyopathy, the pathogenesis of which is poorly understood.The cardiac indices of patients with active acromegaly with no hypertension (Group A, n=4), established hypertension not taking ACEi/ARBs (Group B, n=4) and established hypertension taking ACEi/ARBs (Group C, n=4) were compared using cardiac magnetic imaging.Patients taking ACEi/ARBs had lower end diastolic volume index (EDVi) and end systolic volume index (ESVi) than the other 2 groups ([C] 73.24 vs. [A] 97.92 vs. [B] 101.03 ml/m 2 , ANOVA p=0.034, B vs. C p<0.01). Groups A and B had EDVi and ESVi values at the top of published reference range values; Group C had values in the middle of the range.Acromegaly patients on ACEi/ARBs for hypertension demonstrate improved cardiac indices compared to acromegaly patients with hypertension not taking these medications. Further studies are needed to determine if these drugs have a beneficial cardiac effect in acromegaly in the absence of demonstrable hypertension. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Dual gated PET/CT imaging of small targets of the heart: method description and testing with a dynamic heart phantom.

    PubMed

    Kokki, Tommi; Sipilä, Hannu T; Teräs, Mika; Noponen, Tommi; Durand-Schaefer, Nicolas; Klén, Riku; Knuuti, Juhani

    2010-01-01

    In PET imaging respiratory and cardiac contraction motions interfere the imaging of heart. The aim was to develop and evaluate dual gating method for improving the detection of small targets of the heart. The method utilizes two independent triggers which are sent periodically into list mode data based on respiratory and ECG cycles. An algorithm for generating dual gated segments from list mode data was developed. The test measurements showed that rotational and axial movements of point source can be separated spatially to different segments with well-defined borders. The effect of dual gating on detection of small moving targets was tested with a moving heart phantom. Dual gated images showed 51% elimination (3.6 mm out of 7.0 mm) of contraction motion of hot spot (diameter 3 mm) and 70% elimination (14 mm out of 20 mm) of respiratory motion. Averaged activity value of hot spot increases by 89% when comparing to non-gated images. Patient study of suspected cardiac sarcoidosis shows sharper spatial myocardial uptake profile and improved detection of small myocardial structures such as papillary muscles. The dual gating method improves detection of small moving targets in a phantom and it is feasible in clinical situations.

  10. Design and testing of an MRI-compatible cycle ergometer for non-invasive cardiac assessments during exercise

    PubMed Central

    2012-01-01

    Background Magnetic resonance imaging (MRI) is an important tool for cardiac research, and it is frequently used for resting cardiac assessments. However, research into non-pharmacological stress cardiac evaluation is limited. Methods We aimed to design a portable and relatively inexpensive MRI cycle ergometer capable of continuously measuring pedalling workload while patients exercise to maintain target heart rates. Results We constructed and tested an MRI-compatible cycle ergometer for a 1.5 T MRI scanner. Resting and sub-maximal exercise images (at 110 beats per minute) were successfully obtained in 8 healthy adults. Conclusions The MRI-compatible cycle ergometer constructed by our research group enabled cardiac assessments at fixed heart rates, while continuously recording power output by directly measuring pedal force and crank rotation. PMID:22423637

  11. Reproducibility and Angle Independence of Electromechanical Wave Imaging for the Measurement of Electromechanical Activation during Sinus Rhythm in Healthy Humans.

    PubMed

    Melki, Lea; Costet, Alexandre; Konofagou, Elisa E

    2017-10-01

    Electromechanical wave imaging (EWI) is an ultrasound-based technique that can non-invasively map the transmural electromechanical activation in all four cardiac chambers in vivo. The objective of this study was to determine the reproducibility and angle independence of EWI for the assessment of electromechanical activation during normal sinus rhythm (NSR) in healthy humans. Acquisitions were performed transthoracically at 2000 frames/s on seven healthy human hearts in parasternal long-axis, apical four- and two-chamber views. EWI data was collected twice successively in each view in all subjects, while four successive acquisitions were obtained in one case. Activation maps were generated and compared (i) within the same acquisition across consecutive cardiac cycles; (ii) within same view across successive acquisitions; and (iii) within equivalent left-ventricular regions across different views. EWI was capable of characterizing electromechanical activation during NSR and of reliably obtaining similar patterns of activation. For consecutive heart cycles, the average 2-D correlation coefficient between the two isochrones across the seven subjects was 0.9893, with a mean average activation time fluctuation in LV wall segments across acquisitions of 6.19%. A mean activation time variability of 12% was obtained across different views with a measurement bias of only 3.2 ms. These findings indicate that EWI can map the electromechanical activation during NSR in human hearts in transthoracic echocardiography in vivo and results in reproducible and angle-independent activation maps. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  12. Positron emission tomography for the assessment of myocardial viability: an evidence-based analysis.

    PubMed

    2010-01-01

    In July 2009, the Medical Advisory Secretariat (MAS) began work on Non-Invasive Cardiac Imaging Technologies for the Assessment of Myocardial Viability, an evidence-based review of the literature surrounding different cardiac imaging modalities to ensure that appropriate technologies are accessed by patients undergoing viability assessment. This project came about when the Health Services Branch at the Ministry of Health and Long-Term Care asked MAS to provide an evidentiary platform on effectiveness and cost-effectiveness of non-invasive cardiac imaging modalities.After an initial review of the strategy and consultation with experts, MAS identified five key non-invasive cardiac imaging technologies that can be used for the assessment of myocardial viability: positron emission tomography, cardiac magnetic resonance imaging, dobutamine echocardiography, and dobutamine echocardiography with contrast, and single photon emission computed tomography.A 2005 review conducted by MAS determined that positron emission tomography was more sensitivity than dobutamine echocardiography and single photon emission tomography and dominated the other imaging modalities from a cost-effective standpoint. However, there was inadequate evidence to compare positron emission tomography and cardiac magnetic resonance imaging. Thus, this report focuses on this comparison only. For both technologies, an economic analysis was also completed.The Non-Invasive Cardiac Imaging Technologies for the Assessment of Myocardial Viability is made up of the following reports, which can be publicly accessed at the MAS website at: www.health.gov.on.ca/mas or at www.health.gov.on.ca/english/providers/program/mas/mas_about.htmlPOSITRON EMISSION TOMOGRAPHY FOR THE ASSESSMENT OF MYOCARDIAL VIABILITY: An Evidence-Based AnalysisMAGNETIC RESONANCE IMAGING FOR THE ASSESSMENT OF MYOCARDIAL VIABILITY: An Evidence-Based Analysis The objective of this analysis is to assess the effectiveness and safety of positron emission tomography (PET) imaging using F-18-fluorodeoxyglucose (FDG) for the assessment of myocardial viability. To evaluate the effectiveness of FDG PET viability imaging, the following outcomes are examined: the diagnostic accuracy of FDG PET for predicting functional recovery;the impact of PET viability imaging on prognosis (mortality and other patient outcomes); andthe contribution of PET viability imaging to treatment decision making and subsequent patient outcomes. CONDITION AND TARGET POPULATION LEFT VENTRICULAR SYSTOLIC DYSFUNCTION AND HEART FAILURE: Heart failure is a complex syndrome characterized by the heart's inability to maintain adequate blood circulation through the body leading to multiorgan abnormalities and, eventually, death. Patients with heart failure experience poor functional capacity, decreased quality of life, and increased risk of morbidity and mortality. In 2005, more than 71,000 Canadians died from cardiovascular disease, of which, 54% were due to ischemic heart disease. Left ventricular (LV) systolic dysfunction due to coronary artery disease (CAD) is the primary cause of heart failure accounting for more than 70% of cases. The prevalence of heart failure was estimated at one percent of the Canadian population in 1989. Since then, the increase in the older population has undoubtedly resulted in a substantial increase in cases. Heart failure is associated with a poor prognosis: one-year mortality rates were 32.9% and 31.1% for men and women, respectively in Ontario between 1996 and 1997. IN GENERAL, THERE ARE THREE OPTIONS FOR THE TREATMENT OF HEART FAILURE: medical treatment, heart transplantation, and revascularization for those with CAD as the underlying cause. Concerning medical treatment, despite recent advances, mortality remains high among treated patients, while, heart transplantation is affected by the limited availability of donor hearts and consequently has long waiting lists. The third option, revascularization, is used to restore the flow of blood to the heart via coronary artery bypass grafting (CABG) or through minimally invasive percutaneous coronary interventions (balloon angioplasty and stenting). Both methods, however, are associated with important perioperative risks including mortality, so it is essential to properly select patients for this procedure. Left ventricular dysfunction may be permanent if a myocardial scar is formed, or it may be reversible after revascularization. Reversible LV dysfunction occurs when the myocardium is viable but dysfunctional (reduced contractility). Since only patients with dysfunctional but viable myocardium benefit from revascularization, the identification and quantification of the extent of myocardial viability is an important part of the work-up of patients with heart failure when determining the most appropriate treatment path. Various non-invasive cardiac imaging modalities can be used to assess patients in whom determination of viability is an important clinical issue, specifically: dobutamine echocardiography (echo),stress echo with contrast,SPECT using either technetium or thallium,cardiac magnetic resonance imaging (cardiac MRI), andpositron emission tomography (PET). Stress echocardiography can be used to detect viable myocardium. During the infusion of low dose dobutamine (5 - 10 μg/kg/min), an improvement of contractility in hypokinetic and akentic segments is indicative of the presence of viable myocardium. Alternatively, a low-high dose dobutamine protocol can be used in which a biphasic response characterized by improved contractile function during the low-dose infusion followed by a deterioration in contractility due to stress induced ischemia during the high dose dobutamine infusion (dobutamine dose up to 40 ug/kg/min) represents viable tissue. Newer techniques including echocardiography using contrast agents, harmonic imaging, and power doppler imaging may help to improve the diagnostic accuracy of echocardiographic assessment of myocardial viability. Intravenous contrast agents, which are high molecular weight inert gas microbubbles that act like red blood cells in the vascular space, can be used during echocardiography to assess myocardial viability. These agents allow for the assessment of myocardial blood flow (perfusion) and contractile function (as described above), as well as the simultaneous assessment of perfusion to make it possible to distinguish between stunned and hibernating myocardium. SPECT: SPECT can be performed using thallium-201 (Tl-201), a potassium analogue, or technetium-99 m labelled tracers. When Tl-201 is injected intravenously into a patient, it is taken up by the myocardial cells through regional perfusion, and Tl-201 is retained in the cell due to sodium/potassium ATPase pumps in the myocyte membrane. The stress-redistribution-reinjection protocol involves three sets of images. The first two image sets (taken immediately after stress and then three to four hours after stress) identify perfusion defects that may represent scar tissue or viable tissue that is severely hypoperfused. The third set of images is taken a few minutes after the re-injection of Tl-201 and after the second set of images is completed. These re-injection images identify viable tissue if the defects exhibit significant fill-in (> 10% increase in tracer uptake) on the re-injection images. The other common Tl-201 viability imaging protocol, rest-redistribution, involves SPECT imaging performed at rest five minutes after Tl-201 is injected and again three to four hours later. Viable tissue is identified if the delayed images exhibit significant fill-in of defects identified in the initial scans (> 10% increase in uptake) or if defects are fixed but the tracer activity is greater than 50%. There are two technetium-99 m tracers: sestamibi (MIBI) and tetrofosmin. The uptake and retention of these tracers is dependent on regional perfusion and the integrity of cellular membranes. Viability is assessed using one set of images at rest and is defined by segments with tracer activity greater than 50%. Cardiac magnetic resonance imaging (cardiac MRI) is a non-invasive, x-ray free technique that uses a powerful magnetic field, radio frequency pulses, and a computer to produce detailed images of the structure and function of the heart. Two types of cardiac MRI are used to assess myocardial viability: dobutamine stress magnetic resonance imaging (DSMR) and delayed contrast-enhanced cardiac MRI (DE-MRI). DE-MRI, the most commonly used technique in Ontario, uses gadolinium-based contrast agents to define the transmural extent of scar, which can be visualized based on the intensity of the image. Hyper-enhanced regions correspond to irreversibly damaged myocardium. As the extent of hyper-enhancement increases, the amount of scar increases, so there is a lower the likelihood of functional recovery. Positron emission tomography (PET) is a nuclear medicine technique used to image tissues based on the distinct ways in which normal and abnormal tissues metabolize positron-emitting radionuclides. Radionuclides are radioactive analogs of common physiological substrates such as sugars, amino acids, and free fatty acids that are used by the body. The only licensed radionuclide used in PET imaging for viability assessment is F-18 fluorodeoxyglucose (FDG). During a PET scan, the radionuclides are injected into the body and as they decay, they emit positively charged particles (positrons) that travel several millimetres into tissue and collide with orbiting electrons. (ABSTRACT TRUNCATED)

  13. Review of cardiovascular imaging in The Journal of Nuclear Cardiology in 2014: Part 1 of 2: Positron emission tomography, computed tomography, and neuronal imaging.

    PubMed

    AlJaroudi, Wael A; Hage, Fadi G

    2015-06-01

    The year 2014 has been an exciting year for the cardiovascular imaging community with significant advances in the realm of nuclear and multimodality cardiac imaging. In this new feature of the Journal of Nuclear Cardiology, we will summarize some of the breakthroughs that were published in the Journal in 2014 in 2 sister articles. This first article will concentrate on publications dealing with cardiac positron emission tomography (PET), computed tomography (CT), and neuronal imaging.

  14. Optogenetic control of the cardiac conduction system (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Crocini, Claudia; Ferrantini, Cecilia; Coppini, Raffaele; Loew, Leslie M.; Cerbai, Elisabetta; Poggesi, Corrado; Pavone, Francesco S.; Sacconi, Leonardo

    2016-03-01

    Fatal cardiac arrhythmias are a major medical and social issue in Western countries. Current implantable pacemaker/defibrillators have limited effectiveness and are plagued by frequent malfunctions and complications. Here, we aim at setting up a new method to map and control the electrical activity of whole isolated mouse hearts. We employ a transgenic mouse model expressing Channel Rhodopsin-2 (ChR2) in the heart coupled with voltage optical mapping to monitor and control action potential propagation. The whole heart is loaded with the fluorinated red-shifted voltage sensitive dye (di-4-ANBDQPQ) and imaged with the central portion (128 x 128 pixel) of sCMOS camera operating at frame rate of 1.6 kHz. The wide-field imaging system is implemented with a random access ChR2 activation developed using two orthogonally-mounted acousto-optical deflectors (AODs). AODs rapidly scan different sites of the sample with a commutation time of 4 μs, allowing us to design ad hoc ChR2-stimulation pattern. First, we demonstrate the capability of our system in manipulating the conduction system of the whole mouse heart by changing the electrical propagation features. Then, we explore the efficacy of the random access ChR2 stimulation in inducing arrhythmias as well as to restore the cardiac sinus rhythm during an arrhythmic event. This work shows the potentiality of this new method for studying the mechanisms of arrhythmias and reentry in healthy and diseased hearts, as well as the basis of intra-ventricular dyssynchrony.

  15. W(h)ither human cardiac and body magnetic resonance at ultrahigh fields? technical advances, practical considerations, applications, and clinical opportunities.

    PubMed

    Niendorf, Thoralf; Paul, Katharina; Oezerdem, Celal; Graessl, Andreas; Klix, Sabrina; Huelnhagen, Till; Hezel, Fabian; Rieger, Jan; Waiczies, Helmar; Frahm, Jens; Nagel, Armin M; Oberacker, Eva; Winter, Lukas

    2016-09-01

    The objective of this study was to document and review advances and groundbreaking progress in cardiac and body MR at ultrahigh fields (UHF, B0 ≥ 7.0 T) with the goal to attract talent, clinical adopters, collaborations and resources to the biomedical and diagnostic imaging communities. This review surveys traits, advantages and challenges of cardiac and body MR at 7.0 T. The considerations run the gamut from technical advances to clinical opportunities. Key concepts, emerging technologies, practical considerations, frontier applications and future directions of UHF body and cardiac MR are provided. Examples of UHF cardiac and body imaging strategies are demonstrated. Their added value over the kindred counterparts at lower fields is explored along with an outline of research promises. The achievements of cardiac and body UHF-MR are powerful motivators and enablers, since extra speed, signal and imaging capabilities may be invested to overcome the fundamental constraints that continue to hamper traditional cardiac and body MR applications. If practical obstacles, concomitant physics effects and technical impediments can be overcome in equal measure, sophisticated cardiac and body UHF-MR will help to open the door to new MRI and MRS approaches for basic research and clinical science, with the lessons learned at 7.0 T being transferred into broad clinical use including diagnostics and therapy guiding at lower fields. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Real-time fusion of endoscopic views with dynamic 3-D cardiac images: a phantom study.

    PubMed

    Szpala, Stanislaw; Wierzbicki, Marcin; Guiraudon, Gerard; Peters, Terry M

    2005-09-01

    Minimally invasive robotically assisted cardiac surgical systems currently do not routinely employ 3-D image guidance. However, preoperative magnetic resonance and computed tomography (CT) images have the potential to be used in this role, if appropriately registered with the patient anatomy and animated synchronously with the motion of the actual heart. This paper discusses the fusion of optical images of a beating heart phantom obtained from an optically tracked endoscope, with volumetric images of the phantom created from a dynamic CT dataset. High quality preoperative dynamic CT images are created by first extracting the motion parameters of the heart from the series of temporal frames, and then applying this information to animate a high-quality heart image acquired at end systole. Temporal synchronization of the endoscopic and CT model is achieved by selecting the appropriate CT image from the dynamic set, based on an electrocardiographic trigger signal. The spatial error between the optical and virtual images is 1.4 +/- 1.1 mm, while the time discrepancy is typically 50-100 ms. Index Terms-Image guidance, image warping, minimally invasive cardiac surgery, virtual endoscopy, virtual reality.

  17. Optimization of Rb-82 PET acquisition and reconstruction protocols for myocardial perfusion defect detection

    NASA Astrophysics Data System (ADS)

    Tang, Jing; Rahmim, Arman; Lautamäki, Riikka; Lodge, Martin A.; Bengel, Frank M.; Tsui, Benjamin M. W.

    2009-05-01

    The purpose of this study is to optimize the dynamic Rb-82 cardiac PET acquisition and reconstruction protocols for maximum myocardial perfusion defect detection using realistic simulation data and task-based evaluation. Time activity curves (TACs) of different organs under both rest and stress conditions were extracted from dynamic Rb-82 PET images of five normal patients. Combined SimSET-GATE Monte Carlo simulation was used to generate nearly noise-free cardiac PET data from a time series of 3D NCAT phantoms with organ activities modeling different pre-scan delay times (PDTs) and total acquisition times (TATs). Poisson noise was added to the nearly noise-free projections and the OS-EM algorithm was applied to generate noisy reconstructed images. The channelized Hotelling observer (CHO) with 32× 32 spatial templates corresponding to four octave-wide frequency channels was used to evaluate the images. The area under the ROC curve (AUC) was calculated from the CHO rating data as an index for image quality in terms of myocardial perfusion defect detection. The 0.5 cycle cm-1 Butterworth post-filtering on OS-EM (with 21 subsets) reconstructed images generates the highest AUC values while those from iteration numbers 1 to 4 do not show different AUC values. The optimized PDTs for both rest and stress conditions are found to be close to the cross points of the left ventricular chamber and myocardium TACs, which may promote an individualized PDT for patient data processing and image reconstruction. Shortening the TATs for <~3 min from the clinically employed acquisition time does not affect the myocardial perfusion defect detection significantly for both rest and stress studies.

  18. Cardiac imaging: does radiation matter?

    PubMed Central

    Einstein, Andrew J.; Knuuti, Juhani

    2012-01-01

    The use of ionizing radiation in cardiovascular imaging has generated considerable discussion. Radiation should not be considered in isolation, but rather in the context of a careful examination of the benefits, risks, and costs of cardiovascular imaging. Such consideration requires an understanding of some fundamental aspects of the biology, physics, epidemiology, and terminology germane to radiation, as well as principles of radiological protection. This paper offers a concise, contemporary perspective on these areas by addressing pertinent questions relating to radiation and its application to cardiac imaging. PMID:21828062

  19. High Resolution Magnetic Images of Planar Wave Fronts Reveal Bidomain Properties of Cardiac Tissue

    PubMed Central

    Holzer, Jenny R.; Fong, Luis E.; Sidorov, Veniamin Y.; Wikswo, John P.; Baudenbacher, Franz

    2004-01-01

    We magnetically imaged the magnetic action field and optically imaged the transmembrane potentials generated by planar wavefronts on the surface of the left ventricular wall of Langendorff-perfused isolated rabbit hearts. The magnetic action field images were used to produce a time series of two-dimensional action current maps. Overlaying epifluorescent images allowed us to identify a net current along the wavefront and perpendicular to gradients in the transmembrane potential. This is in contrast to a traditional uniform double-layer model where the net current flows along the gradient in the transmembrane potential. Our findings are supported by numerical simulations that treat cardiac tissue as a bidomain with unequal anisotropies in the intra- and extracellular spaces. Our measurements reveal the anisotropic bidomain nature of cardiac tissue during plane wave propagation. These bidomain effects play an important role in the generation of the whole-heart magnetocardiogram and cannot be ignored. PMID:15377521

  20. Improved cardiac motion detection from ultrasound images using TDIOF: a combined B-mode/ tissue Doppler approach

    NASA Astrophysics Data System (ADS)

    Tavakoli, Vahid; Stoddard, Marcus F.; Amini, Amir A.

    2013-03-01

    Quantitative motion analysis of echocardiographic images helps clinicians with the diagnosis and therapy of patients suffering from cardiac disease. Quantitative analysis is usually based on TDI (Tissue Doppler Imaging) or speckle tracking. These methods are based on two independent techniques - the Doppler Effect and image registration, respectively. In order to increase the accuracy of the speckle tracking technique and cope with the angle dependency of TDI, herein, a combined approach dubbed TDIOF (Tissue Doppler Imaging Optical Flow) is proposed. TDIOF is formulated based on the combination of B-mode and Doppler energy terms in an optical flow framework and minimized using algebraic equations. In this paper, we report on validations with simulated, physical cardiac phantom, and in-vivo patient data. It is shown that the additional Doppler term is able to increase the accuracy of speckle tracking, the basis for several commercially available echocardiography analysis techniques.

  1. Cardiac magnetic resonance imaging and computed tomography in ischemic cardiomyopathy: an update*

    PubMed Central

    Assunção, Fernanda Boldrini; de Oliveira, Diogo Costa Leandro; Souza, Vitor Frauches; Nacif, Marcelo Souto

    2016-01-01

    Ischemic cardiomyopathy is one of the major health problems worldwide, representing a significant part of mortality in the general population nowadays. Cardiac magnetic resonance imaging (CMRI) and cardiac computed tomography (CCT) are noninvasive imaging methods that serve as useful tools in the diagnosis of coronary artery disease and may also help in screening individuals with risk factors for developing this illness. Technological developments of CMRI and CCT have contributed to the rise of several clinical indications of these imaging methods complementarily to other investigation methods, particularly in cases where they are inconclusive. In terms of accuracy, CMRI and CCT are similar to the other imaging methods, with few absolute contraindications and minimal risks of adverse side-effects. This fact strengthens these methods as powerful and safe tools in the management of patients. The present study is aimed at describing the role played by CMRI and CCT in the diagnosis of ischemic cardiomyopathies. PMID:26929458

  2. Cardiac hypertrophy induced by active Raf depends on Yorkie-mediated transcription

    PubMed Central

    Yu, Lin; Daniels, Joseph P.; Wu, Huihui; Wolf, Matthew J.

    2015-01-01

    Organ hypertrophy can result from enlargement of individual cells or from cell proliferation or both. Activating mutations in the serine-threonine kinase Raf cause cardiac hypertrophy and contribute to Noonan syndrome in humans. Cardiac-specific expression of activated Raf also causes hypertrophy in Drosophila melanogaster. We found that Yorkie (Yki), a transcriptional coactivator in the Hippo pathway that regulates organ size, is required for Raf-induced cardiac hypertrophy in flies. Although aberrant activation of Yki orthologs stimulates cardiac hyperplasia in mice, cardiac-specific expression of an activated mutant form of Yki in fruit flies caused cardiac hypertrophy without hyperplasia. Knockdown of Yki caused cardiac dilation without loss of cardiomyocytes and prevented Raf-induced cardiac hypertrophy. In flies, Yki-induced cardiac hypertrophy required the TEA domain–containing transcription factor Scalloped, and, in mammalian cells, expression of mouse RafL613V, an activated form of Raf with a Noonan syndrome mutation, increased Yki-induced Scalloped activity. Furthermore, overexpression of Tgi (a Tondu domain–containing Scalloped-binding corepressor) in the fly heart abrogated Yki- or Raf-induced cardiac hypertrophy. Thus, crosstalk between Raf and Yki occurs in the heart and can influence Raf-mediated cardiac hypertrophy. PMID:25650441

  3. Comprehensive Modeling and Visualization of Cardiac Anatomy and Physiology from CT Imaging and Computer Simulations

    PubMed Central

    Sun, Peng; Zhou, Haoyin; Ha, Seongmin; Hartaigh, Bríain ó; Truong, Quynh A.; Min, James K.

    2016-01-01

    In clinical cardiology, both anatomy and physiology are needed to diagnose cardiac pathologies. CT imaging and computer simulations provide valuable and complementary data for this purpose. However, it remains challenging to gain useful information from the large amount of high-dimensional diverse data. The current tools are not adequately integrated to visualize anatomic and physiologic data from a complete yet focused perspective. We introduce a new computer-aided diagnosis framework, which allows for comprehensive modeling and visualization of cardiac anatomy and physiology from CT imaging data and computer simulations, with a primary focus on ischemic heart disease. The following visual information is presented: (1) Anatomy from CT imaging: geometric modeling and visualization of cardiac anatomy, including four heart chambers, left and right ventricular outflow tracts, and coronary arteries; (2) Function from CT imaging: motion modeling, strain calculation, and visualization of four heart chambers; (3) Physiology from CT imaging: quantification and visualization of myocardial perfusion and contextual integration with coronary artery anatomy; (4) Physiology from computer simulation: computation and visualization of hemodynamics (e.g., coronary blood velocity, pressure, shear stress, and fluid forces on the vessel wall). Substantially, feedback from cardiologists have confirmed the practical utility of integrating these features for the purpose of computer-aided diagnosis of ischemic heart disease. PMID:26863663

  4. New techniques for motion-artifact-free in vivo cardiac microscopy

    PubMed Central

    Vinegoni, Claudio; Lee, Sungon; Aguirre, Aaron D.; Weissleder, Ralph

    2015-01-01

    Intravital imaging microscopy (i.e., imaging in live animals at microscopic resolution) has become an indispensable tool for studying the cellular micro-dynamics in cancer, immunology and neurobiology. High spatial and temporal resolution, combined with large penetration depth and multi-reporter visualization capability make fluorescence intravital microscopy compelling for heart imaging. However, tissue motion caused by cardiac contraction and respiration critically limits its use. As a result, in vitro cell preparations or non-contracting explanted heart models are more commonly employed. Unfortunately, these approaches fall short of understanding the more complex host physiology that may be dynamic and occur over longer periods of time. In this review, we report on novel technologies, which have been recently developed by our group and others, aimed at overcoming motion-induced artifacts and capable of providing in vivo subcellular resolution imaging in the beating mouse heart. The methods are based on mechanical stabilization, image processing algorithms, gated/triggered acquisition schemes or a combination of both. We expect that in the immediate future all these methodologies will have considerable applications in expanding our understanding of the cardiac biology, elucidating cardiomyocyte function and interactions within the organism in vivo, and ultimately improving the treatment of cardiac diseases. PMID:26029116

  5. Beam hardening correction in CT myocardial perfusion measurement

    NASA Astrophysics Data System (ADS)

    So, Aaron; Hsieh, Jiang; Li, Jian-Ying; Lee, Ting-Yim

    2009-05-01

    This paper presents a method for correcting beam hardening (BH) in cardiac CT perfusion imaging. The proposed algorithm works with reconstructed images instead of projection data. It applies thresholds to separate low (soft tissue) and high (bone and contrast) attenuating material in a CT image. The BH error in each projection is estimated by a polynomial function of the forward projection of the segmented image. The error image is reconstructed by back-projection of the estimated errors. A BH-corrected image is then obtained by subtracting a scaled error image from the original image. Phantoms were designed to simulate the BH artifacts encountered in cardiac CT perfusion studies of humans and animals that are most commonly used in cardiac research. These phantoms were used to investigate whether BH artifacts can be reduced with our approach and to determine the optimal settings, which depend upon the anatomy of the scanned subject, of the correction algorithm for patient and animal studies. The correction algorithm was also applied to correct BH in a clinical study to further demonstrate the effectiveness of our technique.

  6. Probabilistic-driven oriented Speckle reducing anisotropic diffusion with application to cardiac ultrasonic images.

    PubMed

    Vegas-Sanchez-Ferrero, G; Aja-Fernandez, S; Martin-Fernandez, M; Frangi, A F; Palencia, C

    2010-01-01

    A novel anisotropic diffusion filter is proposed in this work with application to cardiac ultrasonic images. It includes probabilistic models which describe the probability density function (PDF) of tissues and adapts the diffusion tensor to the image iteratively. For this purpose, a preliminary study is performed in order to select the probability models that best fit the stastitical behavior of each tissue class in cardiac ultrasonic images. Then, the parameters of the diffusion tensor are defined taking into account the statistical properties of the image at each voxel. When the structure tensor of the probability of belonging to each tissue is included in the diffusion tensor definition, a better boundaries estimates can be obtained instead of calculating directly the boundaries from the image. This is the main contribution of this work. Additionally, the proposed method follows the statistical properties of the image in each iteration. This is considered as a second contribution since state-of-the-art methods suppose that noise or statistical properties of the image do not change during the filter process.

  7. A Noninvasive Imaging Modality for Cardiac Arrhythmias

    PubMed Central

    Burnes, John E.; Taccardi, Bruno; Rudy, Yoram

    2007-01-01

    Background The last decade witnessed an explosion of information regarding the genetic, molecular, and mechanistic basis of heart disease. Translating this information into clinical practice requires the development of novel functional imaging modalities for diagnosis, localization, and guided intervention. A noninvasive modality for imaging cardiac arrhythmias is not yet available. Present electrocardiographic methods cannot precisely localize a ventricular tachycardia (VT) or its key reentrant circuit components. Recently, we developed a noninvasive electrocardiographic imaging modality (ECGI) that can reconstruct epicardial electrophysiological information from body surface potentials. Here, we extend its application to image reentrant arrhythmias. Methods and Results Epicardial potentials were recorded during VT with a 490 electrode sock during an open chest procedure in 2 dogs with 4-day-old myocardial infarctions. Body surface potentials were generated from these epicardial potentials in a human torso model. Realistic geometry errors and measurement noise were added to the torso data, which were then used to noninvasively reconstruct epicardial isochrones, electrograms, and potentials with excellent accuracy. ECGI reconstructed the reentry pathway and its key components, including (1) the central common pathway, (2) the VT exit site, (3) lines of block, and (4) regions of slow and fast conduction. This allowed for detailed characterization of the reentrant circuit morphology. Conclusions ECGI can noninvasively image arrhythmic activation on the epicardium during VT to identify and localize key components of the arrhythmogenic pathway that can be effective targets for antiarrhythmic intervention. PMID:11044435

  8. Analyzing Remodeling of Cardiac Tissue: A Comprehensive Approach Based on Confocal Microscopy and 3D Reconstructions

    PubMed Central

    Sachse, F. B.

    2015-01-01

    Microstructural characterization of cardiac tissue and its remodeling in disease is a crucial step in many basic research projects. We present a comprehensive approach for three-dimensional characterization of cardiac tissue at the submicrometer scale. We developed a compression-free mounting method as well as labeling and imaging protocols that facilitate acquisition of three-dimensional image stacks with scanning confocal microscopy. We evaluated the approach with normal and infarcted ventricular tissue. We used the acquired image stacks for segmentation, quantitative analysis and visualization of important tissue components. In contrast to conventional mounting, compression-free mounting preserved cell shapes, capillary lumens and extracellular laminas. Furthermore, the new approach and imaging protocols resulted in high signal-to-noise ratios at depths up to 60 μm. This allowed extensive analyses revealing major differences in volume fractions and distribution of cardiomyocytes, blood vessels, fibroblasts, myofibroblasts and extracellular space in control versus infarct border zone. Our results show that the developed approach yields comprehensive data on microstructure of cardiac tissue and its remodeling in disease. In contrast to other approaches, it allows quantitative assessment of all major tissue components. Furthermore, we suggest that the approach will provide important data for physiological models of cardiac tissue at the submicrometer scale. PMID:26399990

  9. Noninvasive Assessment of Tissue Heating During Cardiac Radiofrequency Ablation Using MRI Thermography

    PubMed Central

    Kolandaivelu, Aravindan; Zviman, Menekhem M.; Castro, Valeria; Lardo, Albert C.; Berger, Ronald D.; Halperin, Henry R.

    2010-01-01

    Background Failure to achieve properly localized, permanent tissue destruction is a common cause of arrhythmia recurrence after cardiac ablation. Current methods of assessing lesion size and location during cardiac radiofrequency ablation are unreliable or not suited for repeated assessment during the procedure. MRI thermography could be used to delineate permanent ablation lesions because tissue heating above 50°C is the cause of permanent tissue destruction during radiofrequency ablation. However, image artifacts caused by cardiac motion, the ablation electrode, and radiofrequency ablation currently pose a challenge to MRI thermography in the heart. In the current study, we sought to demonstrate the feasibility of MRI thermography during cardiac ablation. Methods and Results An MRI-compatible electrophysiology catheter and filtered radiofrequency ablation system was used to perform ablation in the left ventricle of 6 mongrel dogs in a 1.5-T MRI system. Fast gradient-echo imaging was performed before and during radiofrequency ablation, and thermography images were derived from the preheating and postheating images. Lesion extent by thermography was within 20% of the gross pathology lesion. Conclusions MR thermography appears to be a promising technique for monitoring lesion formation and may allow for more accurate placement and titration of ablation, possibly reducing arrhythmia recurrences. PMID:20657028

  10. Assessment of cardiac function using myocardial perfusion imaging technique on SPECT with 99mTc sestamibi

    NASA Astrophysics Data System (ADS)

    Gani, M. R. A.; Nazir, F.; Pawiro, S. A.; Soejoko, D. S.

    2016-03-01

    Suspicion on coronary heart disease can be confirmed by observing the function of left ventricle cardiac muscle with Myocardial Perfusion Imaging techniques. The function perfusion itself is indicated by the uptake of radiopharmaceutical tracer. The 31 patients were studied undergoing the MPI examination on Gatot Soebroto Hospital using 99mTc-sestamibi radiopharmaceutical with stress and rest conditions. Stress was stimulated by physical exercise or pharmacological agent. After two hours, the patient did rest condition on the same day. The difference of uptake percentage between stress and rest conditions will be used to determine the malfunction of perfusion due to ischemic or infarct. Degradation of cardiac function was determined based on the image-based assessment of five segments of left ventricle cardiac. As a result, 8 (25.8%) patients had normal myocardial perfusion and 11 (35.5%) patients suspected for having partial ischemia. Total ischemia occurred to 8 (25.8%) patients with reversible and irreversible ischemia and the remaining 4 (12.9%) patients for partial infarct with characteristic the percentage of perfusion ≤50%. It is concluded that MPI technique of image-based assessment on uptake percentage difference between stress and rest conditions can be employed to predict abnormal perfusion as complementary information to diagnose the cardiac function.

  11. [Cardiac Synchronization Function Estimation Based on ASM Level Set Segmentation Method].

    PubMed

    Zhang, Yaonan; Gao, Yuan; Tang, Liang; He, Ying; Zhang, Huie

    At present, there is no accurate and quantitative methods for the determination of cardiac mechanical synchronism, and quantitative determination of the synchronization function of the four cardiac cavities with medical images has a great clinical value. This paper uses the whole heart ultrasound image sequence, and segments the left & right atriums and left & right ventricles of each frame. After the segmentation, the number of pixels in each cavity and in each frame is recorded, and the areas of the four cavities of the image sequence are therefore obtained. The area change curves of the four cavities are further extracted, and the synchronous information of the four cavities is obtained. Because of the low SNR of Ultrasound images, the boundary lines of cardiac cavities are vague, so the extraction of cardiac contours is still a challenging problem. Therefore, the ASM model information is added to the traditional level set method to force the curve evolution process. According to the experimental results, the improved method improves the accuracy of the segmentation. Furthermore, based on the ventricular segmentation, the right and left ventricular systolic functions are evaluated, mainly according to the area changes. The synchronization of the four cavities of the heart is estimated based on the area changes and the volume changes.

  12. An update on technical and methodological aspects for cardiac PET applications.

    PubMed

    Presotto, Luca; Busnardo, Elena; Gianolli, Luigi; Bettinardi, Valentino

    2016-12-01

    Positron emission tomography (PET) is indicated for a large number of cardiac diseases: perfusion and viability studies are commonly used to evaluate coronary artery disease; PET can also be used to assess sarcoidosis and endocarditis, as well as to investigate amyloidosis. Furthermore, a hot topic for research is plaque characterization. Most of these studies are technically very challenging. High count rates and short acquisition times characterize perfusion scans while very small targets have to be imaged in inflammation/infection and plaques examinations. Furthermore, cardiac PET suffers from respiratory and cardiac motion blur. Each type of studies has specific requirements from the technical and methodological point of view, thus PET systems with overall high performances are required. Furthermore, in the era of hybrid PET/computed tomography (CT) and PET/Magnetic Resonance Imaging (MRI) systems, the combination of complementary functional and anatomical information can be used to improve diagnosis and prognosis. Moreover, PET images can be qualitatively and quantitatively improved exploiting information from the other modality, using advanced algorithms. In this review we will report the latest technological and methodological innovations for PET cardiac applications, with particular reference to the state of the art of the hybrid PET/CT and PET/MRI. We will also report the most recent advancements in software, from reconstruction algorithms to image processing and analysis programs.

  13. Estimating cardiac fiber orientations in pig hearts using registered ultrasound and MR image volumes

    NASA Astrophysics Data System (ADS)

    Dormer, James D.; Meng, Yuguang; Zhang, Xiaodong; Jiang, Rong; Wagner, Mary B.; Fei, Baowei

    2017-03-01

    Heart fiber mechanics can be important predictors in current and future cardiac function. Accurate knowledge of these mechanics could enable cardiologists to provide a diagnosis before conditions progress. Magnetic resonance diffusion tensor imaging (MR-DTI) has been used to determine cardiac fiber orientations. Ultrasound is capable of providing anatomical information in real time, enabling a physician to quickly adjust parameters to optimize image scans. If known fiber orientations from a template heart measured using DTI can be accurately deformed onto a cardiac ultrasound volume, fiber orientations could be estimated for the patient without the need for a costly MR scan while still providing cardiologists valuable information about the heart mechanics. In this study, we apply the method to pig hearts, which are a close representation of human heart anatomy. Experiments from pig hearts show that the registration method achieved an average Dice similarity coefficient (DSC) of 0.819 +/- 0.050 between the ultrasound and deformed MR volumes and that the proposed ultrasound-based method is able to estimate the cardiac fiber orientation in pig hearts.

  14. Left ventricular remodeling leads to heart failure in mice with cardiac-specific overexpression of VEGF-B167: echocardiography and magnetic resonance imaging study.

    PubMed

    Lottonen-Raikaslehto, Line; Rissanen, Riina; Gurzeler, Erika; Merentie, Mari; Huusko, Jenni; Schneider, Jurgen E; Liimatainen, Timo; Ylä-Herttuala, Seppo

    2017-03-01

    Cardiac-specific overexpression of vascular endothelial growth factor (VEGF)-B 167 is known to induce left ventricular hypertrophy due to altered lipid metabolism, in which ceramides accumulate to the heart and cause mitochondrial damage. The aim of this study was to evaluate and compare different imaging methods to find the most sensitive way to diagnose at early stage the progressive left ventricular remodeling leading to heart failure. Echocardiography and cardiovascular magnetic resonance imaging were compared for imaging the hearts of transgenic mice with cardiac-specific overexpression of VEGF-B 167 and wild-type mice from 5 to 14 months of age at several time points. Disease progression was verified by molecular biology methods and histology. We showed that left ventricular remodeling is already ongoing at the age of 5 months in transgenic mice leading to heart failure by the age of 14 months. Measurements from echocardiography and cardiovascular magnetic resonance imaging revealed similar changes in cardiac structure and function in the transgenic mice. Changes in histology, gene expressions, and electrocardiography supported the progression of left ventricular hypertrophy. Longitudinal relaxation time in rotating frame (T 1 ρ ) in cardiovascular magnetic resonance imaging could be suitable for detecting severe fibrosis in the heart. We conclude that cardiac-specific overexpression of VEGF-B 167 leads to left ventricular remodeling at early age and is a suitable model to study heart failure development with different imaging methods. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  15. Five-dimensional motion compensation for respiratory and cardiac motion with cone-beam CT of the thorax region

    NASA Astrophysics Data System (ADS)

    Sauppe, Sebastian; Hahn, Andreas; Brehm, Marcus; Paysan, Pascal; Seghers, Dieter; Kachelrieß, Marc

    2016-03-01

    We propose an adapted method of our previously published five-dimensional (5D) motion compensation (MoCo) algorithm1, developed for micro-CT imaging of small animals, to provide for the first time motion artifact-free 5D cone-beam CT (CBCT) images from a conventional flat detector-based CBCT scan of clinical patients. Image quality of retrospectively respiratory- and cardiac-gated volumes from flat detector CBCT scans is deteriorated by severe sparse projection artifacts. These artifacts further complicate motion estimation, as it is required for MoCo image reconstruction. For high quality 5D CBCT images at the same x-ray dose and the same number of projections as todays 3D CBCT we developed a double MoCo approach based on motion vector fields (MVFs) for respiratory and cardiac motion. In a first step our already published four-dimensional (4D) artifact-specific cyclic motion-compensation (acMoCo) approach is applied to compensate for the respiratory patient motion. With this information a cyclic phase-gated deformable heart registration algorithm is applied to the respiratory motion-compensated 4D CBCT data, thus resulting in cardiac MVFs. We apply these MVFs on double-gated images and thereby respiratory and cardiac motion-compensated 5D CBCT images are obtained. Our 5D MoCo approach processing patient data acquired with the TrueBeam 4D CBCT system (Varian Medical Systems). Our double MoCo approach turned out to be very efficient and removed nearly all streak artifacts due to making use of 100% of the projection data for each reconstructed frame. The 5D MoCo patient data show fine details and no motion blurring, even in regions close to the heart where motion is fastest.

  16. Free-breathing 3D Cardiac MRI Using Iterative Image-Based Respiratory Motion Correction

    PubMed Central

    Moghari, Mehdi H.; Roujol, Sébastien; Chan, Raymond H.; Hong, Susie N.; Bello, Natalie; Henningsson, Markus; Ngo, Long H.; Goddu, Beth; Goepfert, Lois; Kissinger, Kraig V.; Manning, Warren J.; Nezafat, Reza

    2012-01-01

    Respiratory motion compensation using diaphragmatic navigator (NAV) gating with a 5 mm gating window is conventionally used for free-breathing cardiac MRI. Due to the narrow gating window, scan efficiency is low resulting in long scan times, especially for patients with irregular breathing patterns. In this work, a new retrospective motion compensation algorithm is presented to reduce the scan time for free-breathing cardiac MRI that increasing the gating window to 15 mm without compromising image quality. The proposed algorithm iteratively corrects for respiratory-induced cardiac motion by optimizing the sharpness of the heart. To evaluate this technique, two coronary MRI datasets with 1.3 mm3 resolution were acquired from 11 healthy subjects (7 females, 25±9 years); one using a NAV with a 5 mm gating window acquired in 12.0±2.0 minutes and one with a 15 mm gating window acquired in 7.1±1.0 minutes. The images acquired with a 15 mm gating window were corrected using the proposed algorithm and compared to the uncorrected images acquired with the 5 mm and 15 mm gating windows. The image quality score, sharpness, and length of the three major coronary arteries were equivalent between the corrected images and the images acquired with a 5 mm gating window (p-value>0.05), while the scan time was reduced by a factor of 1.7. PMID:23132549

  17. A Phased Array Coil for Human Cardiac Imaging

    PubMed Central

    Constantinides, Chris D.; Westgate, Charles R.; O'Dell, Walter G.; Zerhouni, Elias A.; McVeigh, Elliot R.

    2007-01-01

    A prototype cardiac phased array receiver coil was constructed that comprised a cylindrical array and a separate planar array. Both arrays had two coil loops with the same coil dimensions. Data acquisition with the cylindrical array placed on the human chest, and the planar array placed under the back, yielded an overall enhancement of the signal-to-noise ratio (SNR) over the entire heart by a factor of 1.1–2.85 over a commercially available flexible coil and a commercially available four-loop planar phased array coil. This improvement in SNR can be exploited in cardiac imaging to increase the spatial resolution and reduce the image acquisition time. PMID:7674903

  18. Imaging approaches for the study of cell based cardiac therapies

    PubMed Central

    Lau, Joe F.; Anderson, Stasia A.; Adler, Eric; Frank, Joseph A.

    2009-01-01

    Despite promising preclinical data, the treatment of cardiovascular diseases using embryonic, bone-marrow-derived, and skeletal myoblast stem cells has not yet come to fruition within mainstream clinical practice. Major obstacles in cardiac stem cell investigations include the ability to monitor cell engraftment and survival following implantation within the myocardium. Several cellular imaging modalities, including reporter gene and MRI-based tracking approaches, have emerged that provide the means to identify, localize and monitor stem cells longitudinally in vivo following implantation. This Review will examine the various cardiac cellular tracking modalities, including the combinatorial use of several probes in multimodality imaging, with a focus on data from the last five years. PMID:20027188

  19. Cardiac gating with a pulse oximeter for dual-energy imaging.

    PubMed

    Shkumat, N A; Siewerdsen, J H; Dhanantwari, A C; Williams, D B; Paul, N S; Yorkston, J; Van Metter, R

    2008-11-07

    The development and evaluation of a prototype cardiac gating system for double-shot dual-energy (DE) imaging is described. By acquiring both low- and high-kVp images during the resting phase of the cardiac cycle (diastole), heart misalignment between images can be reduced, thereby decreasing the magnitude of cardiac motion artifacts. For this initial implementation, a fingertip pulse oximeter was employed to measure the peripheral pulse waveform ('plethysmogram'), offering potential logistic, cost and workflow advantages compared to an electrocardiogram. A gating method was developed that accommodates temporal delays due to physiological pulse propagation, oximeter waveform processing and the imaging system (software, filter-wheel, anti-scatter Bucky-grid and flat-panel detector). Modeling the diastolic period allowed the calculation of an implemented delay, t(imp), required to trigger correctly during diastole at any patient heart rate (HR). The model suggests a triggering scheme characterized by two HR regimes, separated by a threshold, HR(thresh). For rates at or below HR(thresh), sufficient time exists to expose on the same heartbeat as the plethysmogram pulse [t(imp)(HR) = 0]. Above HR(thresh), a characteristic t(imp)(HR) delays exposure to the subsequent heartbeat, accounting for all fixed and variable system delays. Performance was evaluated in terms of accuracy and precision of diastole-trigger coincidence and quantitative evaluation of artifact severity in gated and ungated DE images. Initial implementation indicated 85% accuracy in diastole-trigger coincidence. Through the identification of an improved HR estimation method (modified temporal smoothing of the oximeter waveform), trigger accuracy of 100% could be achieved with improved precision. To quantify the effect of the gating system on DE image quality, human observer tests were conducted to measure the magnitude of cardiac artifact under conditions of successful and unsuccessful diastolic gating. Six observers independently measured the artifact in 111 patient DE images. The data indicate that successful diastolic gating results in a statistically significant reduction (p < 0.001) in the magnitude of cardiac motion artifact, with residual artifact attributed primarily to gross patient motion.

  20. Vibration-synchronized magnetic resonance imaging for the detection of myocardial elasticity changes.

    PubMed

    Elgeti, Thomas; Tzschätzsch, Heiko; Hirsch, Sebastian; Krefting, Dagmar; Klatt, Dieter; Niendorf, Thoralf; Braun, Jürgen; Sack, Ingolf

    2012-04-01

    Vibration synchronized magnetic resonance imaging of harmonically oscillating tissue interfaces is proposed for cardiac magnetic resonance elastography. The new approach exploits cardiac triggered cine imaging synchronized with extrinsic harmonic stimulation (f = 22.83 Hz) to display oscillatory tissue deformations in magnitude images. Oscillations are analyzed by intensity threshold-based image processing to track wave amplitude variations over the cardiac cycle. In agreement to literature data, results in 10 volunteers showed that endocardial wave amplitudes during systole (0.13 ± 0.07 mm) were significantly lower than during diastole (0.34 ± 0.14 mm, P < 0.001). Wave amplitudes were found to decrease 117 ± 40 ms before myocardial contraction and to increase 75 ± 31 ms before myocardial relaxation. Vibration synchronized magnetic resonance imaging improves the temporal resolution of magnetic resonance elastography as it overcomes the use of extra motion encoding gradients, is less sensitive to susceptibility artifacts, and does not suffer from dynamic range constraints frequently encountered in phase-based magnetic resonance elastography. Copyright © 2012 Wiley Periodicals, Inc.

  1. USPIO-enhanced 3D-cine self-gated cardiac MRI based on a stack-of-stars golden angle short echo time sequence: Application on mice with acute myocardial infarction.

    PubMed

    Trotier, Aurélien J; Castets, Charles R; Lefrançois, William; Ribot, Emeline J; Franconi, Jean-Michel; Thiaudière, Eric; Miraux, Sylvain

    2016-08-01

    To develop and assess a 3D-cine self-gated method for cardiac imaging of murine models. A 3D stack-of-stars (SOS) short echo time (STE) sequence with a navigator echo was performed at 7T on healthy mice (n = 4) and mice with acute myocardial infarction (MI) (n = 4) injected with ultrasmall superparamagnetic iron oxide (USPIO) nanoparticles. In all, 402 spokes were acquired per stack with the incremental or the golden angle method using an angle increment of (360/402)° or 222.48°, respectively. A cylindrical k-space was filled and repeated with a maximum number of repetitions (NR) of 10. 3D cine cardiac images at 156 μm resolution were reconstructed retrospectively and compared for the two methods in terms of contrast-to-noise ratio (CNR). The golden angle images were also reconstructed with NR = 10, 6, and 3, to assess cardiac functional parameters (ejection fraction, EF) on both animal models. The combination of 3D SOS-STE and USPIO injection allowed us to optimize the identification of cardiac peaks on navigator signal and generate high CNR between blood and myocardium (15.3 ± 1.0). The golden angle method resulted in a more homogeneous distribution of the spokes inside a stack (P < 0.05), enabling reducing the acquisition time to 15 minutes. EF was significantly different between healthy and MI mice (P < 0.05). The method proposed here showed that 3D-cine images could be obtained without electrocardiogram or respiratory gating in mice. It allows precise measurement of cardiac functional parameters even on MI mice. J. Magn. Reson. Imaging 2016;44:355-365. © 2016 Wiley Periodicals, Inc.

  2. Cardiac Structure and Function in Cushing's Syndrome: A Cardiac Magnetic Resonance Imaging Study

    PubMed Central

    Roux, Charles; Salenave, Sylvie; Kachenoura, Nadjia; Raissouni, Zainab; Macron, Laurent; Guignat, Laurence; Jublanc, Christel; Azarine, Arshid; Brailly, Sylvie; Young, Jacques; Mousseaux, Elie; Chanson, Philippe

    2014-01-01

    Background: Patients with Cushing's syndrome have left ventricular (LV) hypertrophy and dysfunction on echocardiography, but echo-based measurements may have limited accuracy in obese patients. No data are available on right ventricular (RV) and left atrial (LA) size and function in these patients. Objectives: The objective of the study was to evaluate LV, RV, and LA structure and function in patients with Cushing's syndrome by means of cardiac magnetic resonance, currently the reference modality in assessment of cardiac geometry and function. Methods: Eighteen patients with active Cushing's syndrome and 18 volunteers matched for age, sex, and body mass index were studied by cardiac magnetic resonance. The imaging was repeated in the patients 6 months (range 2–12 mo) after the treatment of hypercortisolism. Results: Compared with controls, patients with Cushing's syndrome had lower LV, RV, and LA ejection fractions (P < .001 for all) and increased end-diastolic LV segmental thickness (P < .001). Treatment of hypercortisolism was associated with an improvement in ventricular and atrial systolic performance, as reflected by a 15% increase in the LV ejection fraction (P = .029), a 45% increase in the LA ejection fraction (P < .001), and an 11% increase in the RV ejection fraction (P = NS). After treatment, the LV mass index and end-diastolic LV mass to volume ratio decreased by 17% (P < .001) and 10% (P = .002), respectively. None of the patients had late gadolinium myocardial enhancement. Conclusion: Cushing's syndrome is associated with subclinical biventricular and LA systolic dysfunctions that are reversible after treatment. Despite skeletal muscle atrophy, Cushing's syndrome patients have an increased LV mass, reversible upon correction of hypercortisolism. PMID:25093618

  3. The Visible Heart® project and free-access website 'Atlas of Human Cardiac Anatomy'.

    PubMed

    Iaizzo, Paul A

    2016-12-01

    Pre- and post-evaluations of implantable cardiac devices require innovative and critical testing in all phases of the design process. The Visible Heart ® Project was successfully launched in 1997 and 3 years later the Atlas of Human Cardiac Anatomy website was online. The Visible Heart ® methodologies and Atlas website can be used to better understand human cardiac anatomy, disease states and/or to improve cardiac device design throughout the development process. To date, Visible ® Heart methodologies have been used to reanimate 75 human hearts, all considered non-viable for transplantation. The Atlas is a unique free-access website featuring novel images of functional and fixed human cardiac anatomies from >400 human heart specimens. Furthermore, this website includes education tutorials on anatomy, physiology, congenital heart disease and various imaging modalities. For instance, the Device Tutorial provides examples of commonly deployed devices that were present at the time of in vitro reanimation or were subsequently delivered, including: leads, catheters, valves, annuloplasty rings, leadless pacemakers and stents. Another section of the website displays 3D models of vasculature, blood volumes, and/or tissue volumes reconstructed from computed tomography (CT) and magnetic resonance images (MRI) of various heart specimens. A new section allows the user to interact with various heart models. Visible Heart ® methodologies have enabled our laboratory to reanimate 75 human hearts and visualize functional cardiac anatomies and device/tissue interfaces. The website freely shares all images, video clips and CT/MRI DICOM files in honour of the generous gifts received from donors and their families. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For Permissions, please email: journals.permissions@oup.com.

  4. Automated classification of LV regional wall motion based on spatio-temporal profiles from cardiac cine magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Mantilla, Juan; Garreau, Mireille; Bellanger, Jean-Jacques; Paredes, José Luis

    2013-11-01

    Assessment of the cardiac Left Ventricle (LV) wall motion is generally based on visual inspection or quantitative analysis of 2D+t sequences acquired in short-axis cardiac cine-Magnetic Resonance Imaging (MRI). Most often, cardiac dynamic is globally analized from two particular phases of the cardiac cycle. In this paper, we propose an automated method to classify regional wall motion in LV function based on spatio-temporal pro les and Support Vector Machines (SVM). This approach allows to obtain a binary classi cation between normal and abnormal motion, without the need of pre-processing and by exploiting all the images of the cardiac cycle. In each short- axis MRI slice level (basal, median, and apical), the spatio-temporal pro les are extracted from the selection of a subset of diametrical lines crossing opposites LV segments. Initialized at end-diastole phase, the pro les are concatenated with their corresponding projections into the succesive temporal phases of the cardiac cycle. These pro les are associated to di erent types of information that derive from the image (gray levels), Fourier, Wavelet or Curvelet domains. The approach has been tested on a set of 14 abnormal and 6 healthy patients by using a leave-one-out cross validation and two kernel functions for SVM classi er. The best classi cation performance is yielded by using four-level db4 wavelet transform and SVM with a linear kernel. At each slice level the results provided a classi cation rate of 87.14% in apical level, 95.48% in median level and 93.65% in basal level.

  5. Reduced Myocardial Flow Reserve by Positron Emission Tomography Predicts Cardiovascular Events After Cardiac Transplantation.

    PubMed

    Konerman, Matthew C; Lazarus, John J; Weinberg, Richard L; Shah, Ravi V; Ghannam, Michael; Hummel, Scott L; Corbett, James R; Ficaro, Edward P; Aaronson, Keith D; Colvin, Monica M; Koelling, Todd M; Murthy, Venkatesh L

    2018-06-01

    We evaluated the diagnostic and prognostic value of quantification of myocardial flow reserve (MFR) with positron emission tomography (PET) in orthotopic heart transplant patients. We retrospectively identified orthotopic heart transplant patients who underwent rubidium-82 cardiac PET imaging. The primary outcome was the composite of cardiovascular death, acute coronary syndrome, coronary revascularization, and heart failure hospitalization. Cox regression was used to evaluate the association of MFR with the primary outcome. The relationship of MFR and cardiac allograft vasculopathy severity in patients with angiography within 1 year of PET imaging was assessed using Spearman rank correlation and logistic regression. A total of 117 patients (median age, 60 years; 71% men) were identified. Twenty-one of 62 patients (34%) who underwent angiography before PET had cardiac allograft vasculopathy. The median time from orthotopic heart transplant to PET imaging was 6.4 years (median global MFR, 2.31). After a median of 1.4 years, 22 patients (19%) experienced the primary outcome. On an unadjusted basis, global MFR (hazard ratio, 0.22 per unit increase; 95% confidence interval, 0.09-0.50; P <0.001) and stress myocardial blood flow (hazard ratio, 0.48 per unit increase; 95% confidence interval, 0.29-0.79; P =0.004) were associated with the primary outcome. Decreased MFR independently predicted the primary outcome after adjustment for other variables. In 42 patients who underwent angiography within 12 months of PET, MFR and stress myocardial blood flow were associated with moderate-severe cardiac allograft vasculopathy (International Society of Heart and Lung Transplantation grade 2-3). MFR assessed by cardiac rubidium-82 PET imaging is a predictor of cardiovascular events after orthotopic heart transplant and is associated with cardiac allograft vasculopathy severity. © 2018 American Heart Association, Inc.

  6. Three-dimensional-printed cardiac prototypes aid surgical decision-making and preoperative planning in selected cases of complex congenital heart diseases: Early experience and proof of concept in a resource-limited environment.

    PubMed

    Kappanayil, Mahesh; Koneti, Nageshwara Rao; Kannan, Rajesh R; Kottayil, Brijesh P; Kumar, Krishna

    2017-01-01

    Three-dimensional. (3D) printing is an innovative manufacturing process that allows computer-assisted conversion of 3D imaging data into physical "printouts" Healthcare applications are currently in evolution. The objective of this study was to explore the feasibility and impact of using patient-specific 3D-printed cardiac prototypes derived from high-resolution medical imaging data (cardiac magnetic resonance imaging/computed tomography [MRI/CT]) on surgical decision-making and preoperative planning in selected cases of complex congenital heart diseases (CHDs). Five patients with complex CHD with previously unresolved management decisions were chosen. These included two patients with complex double-outlet right ventricle, two patients with criss-cross atrioventricular connections, and one patient with congenitally corrected transposition of great arteries with pulmonary atresia. Cardiac MRI was done for all patients, cardiac CT for one; specific surgical challenges were identified. Volumetric data were used to generate patient-specific 3D models. All cases were reviewed along with their 3D models, and the impact on surgical decision-making and preoperative planning was assessed. Accurate life-sized 3D cardiac prototypes were successfully created for all patients. The models enabled radically improved 3D understanding of anatomy, identification of specific technical challenges, and precise surgical planning. Augmentation of existing clinical and imaging data by 3D prototypes allowed successful execution of complex surgeries for all five patients, in accordance with the preoperative planning. 3D-printed cardiac prototypes can radically assist decision-making, planning, and safe execution of complex congenital heart surgery by improving understanding of 3D anatomy and allowing anticipation of technical challenges.

  7. Cardiac Magnetic Resonance Imaging Predictors of Short-Term Outcomes after High Risk Coronary Surgery.

    PubMed

    Sheriff, Mohammed J; Mouline, Omar; Hsu, Chijen; Grieve, Stuart M; Wilson, Michael K; Bannon, Paul G; Vallely, Michael P; Puranik, Rajesh

    2016-06-01

    The euroSCORE II is a widely used pre-coronary artery bypass graft surgery (CAGS) risk score, but its predictive power lacks the specificity to predict outcomes in high-risk patients (16) and left ventricular (LV) dysfunction (<40%) based on 2D-echocardiography who underwent CAGS and in whom CMRI (1.5T) was performed preoperatively were retrospectively studied. Cardiac magnetic resonance imaging parameters were assessed in patients who either had complications immediately post-surgery (n=35), six weeks post-surgery (n=20) or were uncomplicated. The average age of patients recruited was 69±5 years with high euroSCORE II (22±4) and low 2D-echocardiography LV ejection fraction (38%±2%). Cardiac magnetic resonance imaging results demonstrated that those with immediate complications had higher LV scar/infarct burden as a proportion of LV mass (17±3% vs 10±3%; p=0.04) with lower circumferential relaxation index (2.5±0.46 vs 2.8±0.56; p=0.05) compared to those with no complications. Early mortality from surgery was 17% (n=9) and was associated with lower RV stroke volume (55±12 vs 68±18; p=0.03) and higher LV infarct scar/burden (18±2% vs 10±2%, p=0.04). Cardiac magnetic resonance imaging showed patients with complications at six weeks post-surgery had higher LV scar/infarct burden (14.5±2% vs 6.8±2%, p=0.03) compared to those without complications. Cardiac magnetic resonance imaging preoperative LV and RV parameters are valuable in assessing the likelihood of successful outcomes from CAGS in high-risk patients with LV dysfunction. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  8. Cardiac Involvement in Sarcoidosis: Evolving Concepts in Diagnosis and Treatment

    PubMed Central

    Lynch, Joseph P.; Hwang, Jennifer; Bradfield, Jason; Fishbein, Michael; Shivkumar, Kalyanam; Tung, Roderick

    2014-01-01

    Clinically evident sarcoidosis involving the heart has been noted in at least 2 to 7% of patients with sarcoidosis, but occult involvement is much higher (> 20%). Cardiac sarcoidosis is often not recognized antemortem, as sudden death may be the presenting feature. Cardiac involvement may occur at any point during the course of sarcoidosis and may occur in the absence of pulmonary or systemic involvement. Sarcoidosis can involve any part of the heart, with protean manifestations. Prognosis of cardiac sarcoidosis is related to extent and site(s) of involvement. Most deaths due to cardiac sarcoidosis are due to arrhythmias or conduction defects, but granulomatous infiltration of the myocardium may be lethal. The definitive diagnosis of isolated cardiac sarcoidosis is difficult. The yield of endomyocardial biopsies is low; treatment of cardiac sarcoidosis is often warranted even in the absence of histologic proof. Radionuclide scans are integral to the diagnosis. Currently, 18F-fluorodeoxyglucose positron emission tomography/computed tomography and gadolinium-enhanced magnetic resonance imaging scans are the key imaging modalities to diagnose cardiac sarcoidosis. The prognosis of cardiac sarcoidosis is variable, but mortality rates of untreated cardiac sarcoidosis are high. Although randomized therapeutic trials have not been done, corticosteroids (alone or combined with additional immunosuppressive medications) remain the mainstay of treatment. Because of the potential for sudden cardiac death, implantable cardioverter-defibrillators should be placed in any patient with cardiac sarcoidosis and serious ventricular arrhythmias or heart block, and should be considered for cardiomyopathy. Cardiac transplantation is a viable option for patients with end-stage cardiac sarcoidosis refractory to medical therapy. PMID:25007089

  9. Computational Cardiac Anatomy Using MRI

    PubMed Central

    Beg, Mirza Faisal; Helm, Patrick A.; McVeigh, Elliot; Miller, Michael I.; Winslow, Raimond L.

    2005-01-01

    Ventricular geometry and fiber orientation may undergo global or local remodeling in cardiac disease. However, there are as yet no mathematical and computational methods for quantifying variation of geometry and fiber orientation or the nature of their remodeling in disease. Toward this goal, a landmark and image intensity-based large deformation diffeomorphic metric mapping (LDDMM) method to transform heart geometry into common coordinates for quantification of shape and form was developed. Two automated landmark placement methods for modeling tissue deformations expected in different cardiac pathologies are presented. The transformations, computed using the combined use of landmarks and image intensities, yields high-registration accuracy of heart anatomies even in the presence of significant variation of cardiac shape and form. Once heart anatomies have been registered, properties of tissue geometry and cardiac fiber orientation in corresponding regions of different hearts may be quantified. PMID:15508155

  10. Radiation Dose Estimation for Pediatric Patients Undergoing Cardiac Catheterization

    NASA Astrophysics Data System (ADS)

    Wang, Chu

    Patients undergoing cardiac catheterization are potentially at risk of radiation-induced health effects from the interventional fluoroscopic X-ray imaging used throughout the clinical procedure. The amount of radiation exposure is highly dependent on the complexity of the procedure and the level of optimization in imaging parameters applied by the clinician. For cardiac catheterization, patient radiation dosimetry, for key organs as well as whole-body effective, is challenging due to the lack of fixed imaging protocols, unlike other common X-ray based imaging modalities. Pediatric patients are at a greater risk compared to adults due to their greater cellular radio-sensitivities as well as longer remaining life-expectancy following the radiation exposure. In terms of radiation dosimetry, they are often more challenging due to greater variation in body size, which often triggers a wider range of imaging parameters in modern imaging systems with automatic dose rate modulation. The overall objective of this dissertation was to develop a comprehensive method of radiation dose estimation for pediatric patients undergoing cardiac catheterization. In this dissertation, the research is divided into two main parts: the Physics Component and the Clinical Component. A proof-of-principle study focused on two patient age groups (Newborn and Five-year-old), one popular biplane imaging system, and the clinical practice of two pediatric cardiologists at one large academic medical center. The Physics Component includes experiments relevant to the physical measurement of patient organ dose using high-sensitivity MOSFET dosimeters placed in anthropomorphic pediatric phantoms. First, the three-dimensional angular dependence of MOSFET detectors in scatter medium under fluoroscopic irradiation was characterized. A custom-made spherical scatter phantom was used to measure response variations in three-dimensional angular orientations. The results were to be used as angular dependence correction factors for the MOSFET organ dose measurements in the following studies. Minor angular dependence (< +/-20% at all angles tested, < +/-10% at clinically relevant angles in cardiac catheterization) was observed. Second, the cardiac dose for common fluoroscopic imaging techniques for pediatric patients in the two age groups was measured. Imaging technique settings with variations of individual key imaging parameters were tested to observe the quantitative effect of imaging optimization or lack thereof. Along with each measurement, the two standard system output indices, the Air Kerma (AK) and Dose-Area Product (DAP), were also recorded and compared to the measured cardiac and skin doses -- the lack of correlation between the indices and the organ doses shed light to the substantial limitation of the indices in representing patient radiation dose, at least within the scope of this dissertation. Third, the effective dose (ED) for Posterior-Anterior and Lateral fluoroscopic imaging techniques for pediatric patients in the two age groups was determined. In addition, the dosimetric effect of removing the anti-scatter grid was studied, for which a factor-of-two ED rate reduction was observed for the imaging techniques. The Clinical Component involved analytical research to develop a validated retrospective cardiac dose reconstruction formulation and to propose the new Optimization Index which evaluates the level of optimization of the clinician's imaging usage during a procedure; and small sample group of actual procedures were used to demonstrate applicability of these formulations. In its entirety, the research represents a first-of-its-kind comprehensive approach in radiation dosimetry for pediatric cardiac catheterization; and separately, it is also modular enough that each individual section can serve as study templates for small-scale dosimetric studies of similar purposes. The data collected and algorithmic formulations developed can be of use in areas of personalized patient dosimetry, clinician training, image quality studies and radiation-associated health effect research.

  11. Modeling Patient-Specific Deformable Mitral Valves.

    PubMed

    Ginty, Olivia; Moore, John; Peters, Terry; Bainbridge, Daniel

    2018-06-01

    Medical imaging has advanced enormously over the last few decades, revolutionizing patient diagnostics and care. At the same time, additive manufacturing has emerged as a means of reproducing physical shapes and models previously not possible. In combination, they have given rise to 3-dimensional (3D) modeling, an entirely new technology for physicians. In an era in which 3D imaging has become a standard for aiding in the diagnosis and treatment of cardiac disease, this visualization now can be taken further by bringing the patient's anatomy into physical reality as a model. The authors describe the generalized process of creating a model of cardiac anatomy from patient images and their experience creating patient-specific dynamic mitral valve models. This involves a combination of image processing software and 3D printing technology. In this article, the complexity of 3D modeling is described and the decision-making process for cardiac anesthesiologists is summarized. The management of cardiac disease has been altered with the emergence of 3D echocardiography, and 3D modeling represents the next paradigm shift. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Cardiac involvement in ANCA (+) and ANCA (-) Churg-Strauss syndrome evaluated by cardiovascular magnetic resonance.

    PubMed

    Mavrogeni, Sophie; Karabela, Georgia; Gialafos, Elias; Stavropoulos, Efthymios; Spiliotis, George; Katsifis, Gikas; Kolovou, Genovefa

    2013-10-01

    The cardiovascular magnetic resonance (CMR) pattern of Churg-Strauss syndrome (CSS) includes myopericarditis, diffuse subendocardial vasculitis or myocardial infarction with or without cardiac symptoms and is usually associated with lack of antineutrophil cytoplasmic antibodies (ANCA). To correlate the CMR pattern with ANCA in CSS, compare it with healthy controls and systemic lupus erythematosus (SLE) patients and re-evaluate 2 yrs after the first CMR. 28 consecutive CSS, aged 42±7 yrs, were referred for CMR and 2 yrs re-evaluation. The CMR included left ventricular ejection fraction (LVEF), T2-weighted (T2-W), early (EGE) and late gadolinium enhanced (LGE) imaging. Their results were compared with 28 systemic lupus erythematosus (SLE) under remission and 28 controls with normal myocardial perfusion, assessed by scintigraphy. CMR revealed acute cardiac lesions in all ANCA (-) CSS with active disease and acute cardiac symptoms and only in one asymptomatic ANCA (+) CSS, with active disease. Diffuse subendocardial fibrosis (DSF) or past myocarditis was identified in both ANCA(+) and ANCA (-) CSS, but with higher incidence and fibrosis amount in ANCA (-) CSS (p<0.05). In comparison to SLE, both ANCA (+) and ANCA (-) CSS had higher incidence of DSF, lower incidence of myocarditis and no evidence of myocardial infarction, due to coronary artery disease (p<0.05). In 2 yrs CMR follow up, 1/3 of CSS with DSF presented LV function deterioration and one died, although immunosuppressive treatment was given early after CSS diagnosis. Cardiac involvement either as DSF or myocarditis, can be detected in both ANCA (+) and ANCA (-) CSS, although more clinically overt in ANCA (-). DSF carries an ominous prognosis for LV function. CMR, due to its capability to detect disease severity, before cardiac dysfunction takes place, is an excellent tool for CSS risk stratification and treatment individualization.

  13. Anatomical and echocardiographic correlates of normal cardiac morphology in the late first trimester fetus.

    PubMed Central

    Allan, L. D.; Santos, R.; Pexieder, T.

    1997-01-01

    OBJECTIVES: To describe the normal cardiac morphology as seen by transvaginal ultrasound imaging in the first trimester fetus and to compare it with the morphology of the heart as seen by microdissection at the same gestational age. DESIGN: In 53 mothers undergoing early sonography, the fetal heart was examined and the images recorded. The gestational age range was 5-12 weeks of gestation, which represents 21 to 70 days after conception. Images were analysed frame by frame and compared with the anatomy of embryos and fetuses at the same gestational ages. RESULTS: After the 9th week of gestation, four cardiac chambers, the aortic origin, and the pulmonary artery could be identified on cross sectional echocardiography in conjunction with colour flow Doppler. At 9 weeks, the apex pointed anteriorly and the right ventricle and pulmonary artery lay to the right of the midline. By the 11th week of gestation, the apex pointed to the left and the pulmonary artery lay to the left of the midline as in the older fetus. Between 9 and 12 weeks' gestation the aorta was larger than the pulmonary artery. These findings were confirmed in the microdissected hearts. CONCLUSIONS: The current quality of ultrasound images obtained using transvaginal transducers in the first trimester fetus allows the study of fetal cardiac anatomy. Some of the later developmental changes can be demonstrated. As technology improves further the details of earlier cardiac morphogenesis may also become visible. Images PMID:9038698

  14. The contribution of coping related variables and cardiac vagal activity on the performance of a dart throwing task under pressure.

    PubMed

    Mosley, Emma; Laborde, Sylvain; Kavanagh, Emma

    2017-10-01

    The aims of this study were 1) to assess the predictive role of coping related variables (CRV) on cardiac vagal activity (derived from heart rate variability), and 2) to investigate the influence of CRV (including cardiac vagal activity) on a dart throwing task under low pressure (LP) and high pressure (HP) conditions. Participants (n=51) completed trait CRV questionnaires: Decision Specific Reinvestment Scale, Movement Specific Reinvestment Scale and Trait Emotional Intelligence Questionnaire. They competed in a dart throwing task under LP and HP conditions. Cardiac vagal activity measurements were taken at resting, task and during recovery for 5min. Self-reported ratings of stress were recorded at three time points via a visual analogue scale. Upon completion of the task, self-report measures of motivation, stress appraisal, attention, perceived pressure and dart throwing experience were completed. Results indicated that resting cardiac vagal activity had no predictors. Task cardiac vagal activity was predicted by resting cardiac vagal activity in both pressure conditions with the addition of a trait CRV in HP. Post task cardiac vagal activity was predicted by resting cardiac vagal activity in both conditions with the addition of a trait CRV in HP. Cardiac vagal reactivity (difference from resting to task) was predicted by a trait CRV in HP conditions. Cardiac vagal recovery (difference from task to post task) was predicted by a state CRV only in LP. Dart throwing task performance was predicted by a combination of both CRV and cardiac vagal activity. The current research suggests that coping related variables and cardiac vagal activity influence dart throwing task performance differently dependent on pressure condition. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. ⁶⁸Ga-DOTA-TOC-PET/CT detects heart metastases from ileal neuroendocrine tumors.

    PubMed

    Calissendorff, Jan; Sundin, Anders; Falhammar, Henrik

    2014-09-01

    Metastases from ileal neuroendocrine tumors (NETs) to the myocardium are rare and generally seen in patients with widespread metastatic NET disease. The objectives of this investigation were to describe the frequency of intracardiac metastases in ileal NET patients examined by (68)Ga-DOTA-TOC-PET/CT and to describe the cases in detail. All (68)Ga-DOTA-TOC-PET/CT examinations performed at the Karolinska University Hospital since 2010 until April 2012 were reviewed. In all, 128 out of 337 examinations were in patients with ileal NETs. Four patients had seven myocardiac metastases, yielding a frequency of 4.3 % in patients with ileal NETs. One patient had cardiac surgery while three were treated with somatostatin analogs. The cardiac metastases did not affect the patients' activity of daily life. (68)Ga-DOTA-TOC-PET/CT is an established imaging modality in identifying cardiac metastases in ileal NETs. Prospective studies are needed to confirm the true clinical value of (68)Ga-DOTA-TOC-PET/CT in detecting cardiac metastases in both ileal and non-ileal NETs.

  16. The challenge of cardiac modeling--interaction and integration.

    PubMed

    Sideman, Samuel

    2006-10-01

    The goal of clinical cardiology is to obtain an integrated picture of the interacting parameters of muscle and vessel mechanics, blood circulation and myocardial perfusion, oxygen consumption and energy metabolism, and electrical activation and heart rate, thus relating to the true physiological and pathophysiological characteristics of the heart. Scientific insight into the cardiac physiology and performance is achieved by utilizing life sciences, for example, molecular biology, genetics and related intra- and intercellular phenomena, as well as the exact sciences, for example, mathematics, computer science, and related imaging and visualization techniques. The tools to achieve these goals are based on the intimate interactions between engineering science and medicine and the developments of modern, medically oriented technology. Most significant is the beneficiary effect of the globalization of science, the Internet, and the unprecedented international interaction and scientific cooperation in facing difficult multidisciplined challenges. This meeting aims to explore some important interactions in the cardiac system and relate to the integration of spatial and temporal interacting system parameters, so as to gain better insight into the structure and function of the cardiac system, thus leading to better therapeutic modalities.

  17. Flexible reduced field of view magnetic resonance imaging based on single-shot spatiotemporally encoded technique

    NASA Astrophysics Data System (ADS)

    Li, Jing; Cai, Cong-Bo; Chen, Lin; Chen, Ying; Qu, Xiao-Bo; Cai, Shu-Hui

    2015-10-01

    In many ultrafast imaging applications, the reduced field-of-view (rFOV) technique is often used to enhance the spatial resolution and field inhomogeneity immunity of the images. The stationary-phase characteristic of the spatiotemporally-encoded (SPEN) method offers an inherent applicability to rFOV imaging. In this study, a flexible rFOV imaging method is presented and the superiority of the SPEN approach in rFOV imaging is demonstrated. The proposed method is validated with phantom and in vivo rat experiments, including cardiac imaging and contrast-enhanced perfusion imaging. For comparison, the echo planar imaging (EPI) experiments with orthogonal RF excitation are also performed. The results show that the signal-to-noise ratios of the images acquired by the proposed method can be higher than those obtained with the rFOV EPI. Moreover, the proposed method shows better performance in the cardiac imaging and perfusion imaging of rat kidney, and it can scan one or more regions of interest (ROIs) with high spatial resolution in a single shot. It might be a favorable solution to ultrafast imaging applications in cases with severe susceptibility heterogeneities, such as cardiac imaging and perfusion imaging. Furthermore, it might be promising in applications with separate ROIs, such as mammary and limb imaging. Project supported by the National Natural Science Foundation of China (Grant Nos. 11474236, 81171331, and U1232212).

  18. Adult congenital heart disease imaging with second-generation dual-source computed tomography: initial experiences and findings.

    PubMed

    Ghoshhajra, Brian B; Sidhu, Manavjot S; El-Sherief, Ahmed; Rojas, Carlos; Yeh, Doreen Defaria; Engel, Leif-Christopher; Liberthson, Richard; Abbara, Suhny; Bhatt, Ami

    2012-01-01

    Adult congenital heart disease patients present a unique challenge to the cardiac imager. Patients may present with both acute and chronic manifestations of their complex congenital heart disease and also require surveillance for sequelae of their medical and surgical interventions. Multimodality imaging is often required to clarify their anatomy and physiology. Radiation dose is of particular concern in these patients with lifelong imaging needs for their chronic disease. The second-generation dual-source scanner is a recently available advanced clinical cardiac computed tomography (CT) scanner. It offers a combination of the high-spatial resolution of modern CT, the high-temporal resolution of dual-source technology, and the wide z-axis coverage of modern cone-beam geometry CT scanners. These advances in technology allow novel protocols that markedly reduce scan time, significantly reduce radiation exposure, and expand the physiologic imaging capabilities of cardiac CT. We present a case series of complicated adult congenital heart disease patients imaged by the second-generation dual-source CT scanner with extremely low-radiation doses and excellent image quality. © 2012 Wiley Periodicals, Inc.

  19. In vivo imaging of cardiac development and function in zebrafish using light sheet microscopy.

    PubMed

    Weber, Michael; Huisken, Jan

    2015-01-01

    Detailed studies of heart development and function are crucial for our understanding of cardiac failures and pave the way for better diagnostics and treatment. However, the constant motion and close incorporation into the cardiovascular system prevent in vivo studies of the living, unperturbed heart. The complementary strengths of the zebrafish model and light sheet microscopy provide a useful platform to fill this gap. High-resolution images of the embryonic vertebrate heart are now recorded from within the living animal: deep inside the unperturbed heart we can follow cardiac contractions and measure action potentials and calcium transients. Three-dimensional reconstructions of the entire beating heart with cellular resolution give new insights into its ever-changing morphology and facilitate studies into how individual cells form the complex cardiac network. In addition, cardiac dynamics and robustness are now examined with targeted optical manipulation. Overall, the combination of zebrafish and light sheet microscopy represents a promising addition for cardiac research and opens the door to a better understanding of heart function and development.

  20. Targeted in-vivo computed tomography (CT) imaging of tissue ACE using concentrated lisinopril-capped gold nanoparticle solutions

    NASA Astrophysics Data System (ADS)

    Daniel, Marie-Christine; Aras, Omer; Smith, Mark F.; Nan, Anjan; Fleiter, Thorsten

    2010-04-01

    The development of cardiac and pulmonary fibrosis have been associated with overexpression of angiotensin-converting enzyme (ACE). Moreover, ACE inhibitors, such as lisinopril, have shown a benificial effect for patients diagnosed with heart failure or systemic hypertension. Thus targeted imaging of the ACE is of crucial importance for monitoring of the tissue ACE activity as well as the treatment efficacy in heart failure. In this respect, lisinopril-capped gold nanoparticles were prepared to provide a new type of probe for targeted molecular imaging of ACE by tuned K-edge computed tomography (CT) imaging. Concentrated solutions of these modified gold nanoparticles, with a diameter around 16 nm, showed high contrast in CT imaging. These new targeted imaging agents were thus used for in vivo imaging on rat models.

  1. Automatic Parameterization Strategy for Cardiac Electrophysiology Simulations.

    PubMed

    Costa, Caroline Mendonca; Hoetzl, Elena; Rocha, Bernardo Martins; Prassl, Anton J; Plank, Gernot

    2013-10-01

    Driven by recent advances in medical imaging, image segmentation and numerical techniques, computer models of ventricular electrophysiology account for increasingly finer levels of anatomical and biophysical detail. However, considering the large number of model parameters involved parameterization poses a major challenge. A minimum requirement in combined experimental and modeling studies is to achieve good agreement in activation and repolarization sequences between model and experiment or patient data. In this study, we propose basic techniques which aid in determining bidomain parameters to match activation sequences. An iterative parameterization algorithm is implemented which determines appropriate bulk conductivities which yield prescribed velocities. In addition, a method is proposed for splitting the computed bulk conductivities into individual bidomain conductivities by prescribing anisotropy ratios.

  2. Williams Syndrome and Anesthesia for Non-cardiac Surgery: High Risk Can Be Mitigated with Appropriate Planning.

    PubMed

    Brown, Morgan L; Nasr, Viviane G; Toohey, Rebecca; DiNardo, James A

    2018-03-23

    Patients with Williams syndrome are considered at high risk for anesthesia-related adverse events. At our institution, all William syndrome patients undergoing cardiac surgical, cardiac catheterization/interventional procedures, and cardiac imaging studies are cared for by cardiac anesthesiologists. All William syndrome patients undergoing non-cardiac surgical, interventional, or imaging studies are cared for by main operating room pediatric anesthesiologists with consultative input from a cardiac anesthesiologist. We reviewed our experience with 75 patients undergoing 202 separate anesthetics for 95 non-cardiac procedures and 107 cardiac procedures from 2012 to 2016. The mean age was 7.5 ± 7.0 years and the mean weight was 22.3 ± 17.0 kg. One hundred and eighty-seven patients had a general anesthetic (92.6%). Medications used included etomidate in 26.2%, propofol in 37.6%, isoflurane in 47.5%, and sevoflurane in 68.3%. Vasopressors and inotropes were required including calcium (22.8%), dopamine (10.4%), norepinephrine (17.3%), phenylephrine (35.1%), vasopressin (0.5%), and ephedrine (5.4%). The median length of stay after anesthesia was 2.8 days (range 0-32). No adverse events occurred in 89.6% of anesthetics. There were two cases of cardiac arrest, one of which required extracorporeal life support for resuscitation. Of the non-cardiac surgical procedures, 95.7% did not have a cardiovascular adverse event. Patients with Williams syndrome are at high risk for anesthesia, especially when undergoing cardiac procedures. The risk can be mitigated with appropriate planning and adherence to the hemodynamic goals for non-cardiac surgical procedures.

  3. Total Artificial Heart Implantation as a Bridge to Heart Transplantation in an Active Duty Service Member With Amyloid Cardiomyopathy.

    PubMed

    Scully, Michael S; Wessman, Dylan E; McKee, James M; Francisco, Gregory M; Nayak, Keshav R; Kobashigawa, Jon A

    2017-03-01

    Cardiac involvement by light-chain (AL) amyloid occurs in up to 50% of patients with primary AL amyloidosis. The prognosis of amyloid heart disease is poor with 1-year survival rates of 35 to 40%. Historically, heart transplantation was considered controversial for patients with AL amyloid cardiomyopathy (CM) given the systemic nature of the disease and poor survival. We present a case report of an active duty service member diagnosed with advanced cardiac amyloid who underwent total artificial heart transplant as a bridge to heart transplant and eventual autologous stem cell transplant. A 47-year-old active duty male initially evaluated for atypical chest pain was found to have severe concentric left ventricular hypertrophy on echocardiogram but normal voltage on electrocardiogram. Cardiac magnetic resonance imaging, laboratory studies, and bone marrow biopsy established the diagnosis of cardiac amyloidosis. At the time of diagnosis, the patient's prognosis was very poor with a median survival of 5 months on the basis of the Mayo Clinic revised prognostic staging system for amyloidosis. The patient developed rapidly progressive left ventricular dysfunction and heart failure leading to cardiac arrest. The patient received a total artificial heart as a bridge to orthotopic heart and kidney transplantation and eventual stem cell transplant. He continues to be in remission and has a fair functional capacity without restriction in activities of daily living or moderate exercise. Amyloid CM is a rare and devastating disease. The natural course of the disease has made heart transplant in these patients controversial. Modern advancements in chemotherapies and advanced heart failure treatments have improved outcomes for select patients with AL amyloid CM undergoing heart transplantation. There is ongoing research seeking improvement in treatment options and outcomes for patients with this deadly disease. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.

  4. Dual respiratory and cardiac motion estimation in PET imaging: Methods design and quantitative evaluation.

    PubMed

    Feng, Tao; Wang, Jizhe; Tsui, Benjamin M W

    2018-04-01

    The goal of this study was to develop and evaluate four post-reconstruction respiratory and cardiac (R&C) motion vector field (MVF) estimation methods for cardiac 4D PET data. In Method 1, the dual R&C motions were estimated directly from the dual R&C gated images. In Method 2, respiratory motion (RM) and cardiac motion (CM) were separately estimated from the respiratory gated only and cardiac gated only images. The effects of RM on CM estimation were modeled in Method 3 by applying an image-based RM correction on the cardiac gated images before CM estimation, the effects of CM on RM estimation were neglected. Method 4 iteratively models the mutual effects of RM and CM during dual R&C motion estimations. Realistic simulation data were generated for quantitative evaluation of four methods. Almost noise-free PET projection data were generated from the 4D XCAT phantom with realistic R&C MVF using Monte Carlo simulation. Poisson noise was added to the scaled projection data to generate additional datasets of two more different noise levels. All the projection data were reconstructed using a 4D image reconstruction method to obtain dual R&C gated images. The four dual R&C MVF estimation methods were applied to the dual R&C gated images and the accuracy of motion estimation was quantitatively evaluated using the root mean square error (RMSE) of the estimated MVFs. Results show that among the four estimation methods, Methods 2 performed the worst for noise-free case while Method 1 performed the worst for noisy cases in terms of quantitative accuracy of the estimated MVF. Methods 4 and 3 showed comparable results and achieved RMSE lower by up to 35% than that in Method 1 for noisy cases. In conclusion, we have developed and evaluated 4 different post-reconstruction R&C MVF estimation methods for use in 4D PET imaging. Comparison of the performance of four methods on simulated data indicates separate R&C estimation with modeling of RM before CM estimation (Method 3) to be the best option for accurate estimation of dual R&C motion in clinical situation. © 2018 American Association of Physicists in Medicine.

  5. Patient-Adaptive Reconstruction and Acquisition in Dynamic Imaging with Sensitivity Encoding (PARADISE)

    PubMed Central

    Sharif, Behzad; Derbyshire, J. Andrew; Faranesh, Anthony Z.; Bresler, Yoram

    2010-01-01

    MR imaging of the human heart without explicit cardiac synchronization promises to extend the applicability of cardiac MR to a larger patient population and potentially expand its diagnostic capabilities. However, conventional non-gated imaging techniques typically suffer from low image quality or inadequate spatio-temporal resolution and fidelity. Patient-Adaptive Reconstruction and Acquisition in Dynamic Imaging with Sensitivity Encoding (PARADISE) is a highly-accelerated non-gated dynamic imaging method that enables artifact-free imaging with high spatio-temporal resolutions by utilizing novel computational techniques to optimize the imaging process. In addition to using parallel imaging, the method gains acceleration from a physiologically-driven spatio-temporal support model; hence, it is doubly accelerated. The support model is patient-adaptive, i.e., its geometry depends on dynamics of the imaged slice, e.g., subject’s heart-rate and heart location within the slice. The proposed method is also doubly adaptive as it adapts both the acquisition and reconstruction schemes. Based on the theory of time-sequential sampling, the proposed framework explicitly accounts for speed limitations of gradient encoding and provides performance guarantees on achievable image quality. The presented in-vivo results demonstrate the effectiveness and feasibility of the PARADISE method for high resolution non-gated cardiac MRI during a short breath-hold. PMID:20665794

  6. 2D XD-GRASP provides better image quality than conventional 2D cardiac cine MRI for patients who cannot suspend respiration

    PubMed Central

    Piekarski, Eve; Chitiboi, Teodora; Ramb, Rebecca; Latson, Larry A; Bhatla, Puneet; Feng, Li; Axel, Leon

    2017-01-01

    Object Residual respiratory motion degrades image quality in conventional cardiac cine MRI (CCMR). We evaluated whether a free-breathing (FB) radial imaging CCMR sequence with compressed sensing reconstruction (eXtra-Dimension (e.g. cardiac and respiratory phases) Golden-angle RAdial Sparse Parallel, or XD-GRASP) could provide better image quality than a conventional Cartesian breath-held (BH) sequence, in an unselected population of patients undergoing clinical CCMR. Material and Methods 101 patients who underwent BH and FB imaging in a mid-ventricular short-axis plane at a matching location were included. Visual and quantitative image analysis was performed by two blinded experienced readers, using a 5-point qualitative scale to score overall image quality and visual signal-to-noise ratio (SNR) grade, with measures of noise and sharpness. End-diastole (ED) and end-systole (ES) left-ventricular areas were also measured and compared for both BH and FB images. Results Image quality was generally better with the BH cines (overall quality grade BH vs FB: 4 vs 2.9, p<0.001; noise 0.06 vs 0.08 p< 0.001; SNR grade: 4.1 vs 3, p<0.001), except for sharpness (p=0.48). There were no significant differences between BH and FB images regarding ED or ES areas (p=0.35 and 0.12). 18 of the 101 patients had impaired BH image quality (grades 1 or 2). In this subgroup, image quality of the FB images was better (p=0.0032), as was the SNR grade (p=0.003), but there were no significant differences regarding noise and sharpness (p=0.45, p=0.47). Conclusion Although FB XD-GRASP CCMR was visually inferior to conventional BH cardiac cine in general, it provided improved image quality in the subgroup of patients presenting respiratory motion-induced artifacts on breath-held images. PMID:29067539

  7. Temporal resolution improvement using PICCS in MDCT cardiac imaging

    PubMed Central

    Chen, Guang-Hong; Tang, Jie; Hsieh, Jiang

    2009-01-01

    The current paradigm for temporal resolution improvement is to add more source-detector units and∕or increase the gantry rotation speed. The purpose of this article is to present an innovative alternative method to potentially improve temporal resolution by approximately a factor of 2 for all MDCT scanners without requiring hardware modification. The central enabling technology is a most recently developed image reconstruction method: Prior image constrained compressed sensing (PICCS). Using the method, cardiac CT images can be accurately reconstructed using the projection data acquired in an angular range of about 120°, which is roughly 50% of the standard short-scan angular range (∼240° for an MDCT scanner). As a result, the temporal resolution of MDCT cardiac imaging can be universally improved by approximately a factor of 2. In order to validate the proposed method, two in vivo animal experiments were conducted using a state-of-the-art 64-slice CT scanner (GE Healthcare, Waukesha, WI) at different gantry rotation times and different heart rates. One animal was scanned at heart rate of 83 beats per minute (bpm) using 400 ms gantry rotation time and the second animal was scanned at 94 bpm using 350 ms gantry rotation time, respectively. Cardiac coronary CT imaging can be successfully performed at high heart rates using a single-source MDCT scanner and projection data from a single heart beat with gantry rotation times of 400 and 350 ms. Using the proposed PICCS method, the temporal resolution of cardiac CT imaging can be effectively improved by approximately a factor of 2 without modifying any scanner hardware. This potentially provides a new method for single-source MDCT scanners to achieve reliable coronary CT imaging for patients at higher heart rates than the current heart rate limit of 70 bpm without using the well-known multisegment FBP reconstruction algorithm. This method also enables dual-source MDCT scanner to achieve higher temporal resolution without further hardware modifications. PMID:19610302

  8. Temporal resolution improvement using PICCS in MDCT cardiac imaging.

    PubMed

    Chen, Guang-Hong; Tang, Jie; Hsieh, Jiang

    2009-06-01

    The current paradigm for temporal resolution improvement is to add more source-detector units and/or increase the gantry rotation speed. The purpose of this article is to present an innovative alternative method to potentially improve temporal resolution by approximately a factor of 2 for all MDCT scanners without requiring hardware modification. The central enabling technology is a most recently developed image reconstruction method: Prior image constrained compressed sensing (PICCS). Using the method, cardiac CT images can be accurately reconstructed using the projection data acquired in an angular range of about 120 degrees, which is roughly 50% of the standard short-scan angular range (approximately 240 degrees for an MDCT scanner). As a result, the temporal resolution of MDCT cardiac imaging can be universally improved by approximately a factor of 2. In order to validate the proposed method, two in vivo animal experiments were conducted using a state-of-the-art 64-slice CT scanner (GE Healthcare, Waukesha, WI) at different gantry rotation times and different heart rates. One animal was scanned at heart rate of 83 beats per minute (bpm) using 400 ms gantry rotation time and the second animal was scanned at 94 bpm using 350 ms gantry rotation time, respectively. Cardiac coronary CT imaging can be successfully performed at high heart rates using a single-source MDCT scanner and projection data from a single heart beat with gantry rotation times of 400 and 350 ms. Using the proposed PICCS method, the temporal resolution of cardiac CT imaging can be effectively improved by approximately a factor of 2 without modifying any scanner hardware. This potentially provides a new method for single-source MDCT scanners to achieve reliable coronary CT imaging for patients at higher heart rates than the current heart rate limit of 70 bpm without using the well-known multisegment FBP reconstruction algorithm. This method also enables dual-source MDCT scanner to achieve higher temporal resolution without further hardware modifications.

  9. [Isolated left ventricular non-compaction associated with Ebstein's anomaly. Multimodality non-invasive imaging for the assessment of congenital heart disease].

    PubMed

    Renilla, Alfredo; Santamarta, Elena; Corros, Cecilia; Martín, María; Barreiro, Manuel; de la Hera, Jesús

    2013-01-01

    To establish the etiology of heart failure in patients with congenital heart disease can be challenging. Multiple concomitant anomalies that can be missed after an initial diagnosis could be seen in these patients. In patients with congenital heart disease, a more accurate evaluation of cardiac morphology and left ventricular systolic function could be evaluated by recent non-invasive cardiac imaging techniques. We present a rare case where multimodal cardiac imaging was useful to establish the final diagnosis of left ventricular non-compaction associated with Ebstein's anomaly. Copyright © 2012 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  10. The continual innovation of commercial PET/CT solutions in nuclear cardiology: Siemens Healthineers.

    PubMed

    Bendriem, Bernard; Reed, Jessie; McCullough, Kathryn; Khan, Mohammad Raza; Smith, Anne M; Thomas, Damita; Long, Misty

    2018-04-10

    Cardiac PET/CT is an evolving, non-invasive imaging modality that impacts patient management in many clinical scenarios. Beyond offering the capability to assess myocardial perfusion, inflammatory cardiac pathologies, and myocardial viability, cardiac PET/CT also allows for the non-invasive quantitative assessment of myocardial blood flow (MBF) and myocardial flow reserve (MFR). Recognizing the need for an enhanced comprehension of coronary physiology, Siemens Healthineers implemented a sophisticated solution for the calculation of MBF and MFR in 2009. As a result, each aspect of their innovative scanner and image-processing technology seamlessly integrates into an efficient, easy-to-use workflow for everyday clinical use that maximizes the number of patients who potentially benefit from this imaging modality.

  11. Cardiac investigation in patients with diabetes.

    PubMed

    Tardif, Jean-Claude

    2006-02-01

    Most patients with type 2 diabetes die from heart disease. Screening for the presence of myocardial ischemia is of clinical importance in the management of this population. The pain response to ischemia can be either absent or blunted in diabetes, resulting in the absence of symptoms or an atypical presentation. Exercise electrocardiogram (ECG) should be the initial test in men who are able to exercise and have a normal resting ECG. Stress cardiac imaging should be the initial test in diabetic men with an abnormal resting ECG or who are not able to exercise. More widespread use of cardiac imaging is probably justified in diabetic women and patients with suspected coronary artery disease. Official guidelines for appropriate and cost-effective cardiac investigation should help physicians manage diabetic patients.

  12. Tracking Organs Composed of One or Multiple Regions Using Geodesic Active Region Models

    NASA Astrophysics Data System (ADS)

    Martínez, A.; Jiménez, J. J.

    In radiotherapy treatment it is very important to find out the target organs on the medical image sequence in order to determine and apply the proper dose. The techniques to achieve this goal can be classified into extrinsic and intrinsic. Intrinsic techniques only use image processing with medical images associated to the radiotherapy treatment, as we deal in this chapter. To accurately perform this organ tracking it is necessary to find out segmentation and tracking models that were able to be applied to several image modalities involved on a radiotherapy session (CT See Modality , MRI , etc.). The movements of the organs are mainly affected by two factors: breathing and involuntary movements associated with the internal organs or patient positioning. Among the several alternatives to track the organs of interest, a model based on geodesic active regions is proposed. This model has been tested over CT images from the pelvic, cardiac, and thoracic area. A new model for the segmentation of organs composed by more than one region is proposed.

  13. Addressing Common Questions Encountered in the Diagnosis and Management of Cardiac Amyloidosis

    PubMed Central

    Maurer, Mathew S.; Elliott, Perry; Comenzo, Raymond; Semigran, Marc; Rapezzi, Claudio

    2017-01-01

    Advances in cardiac imaging have resulted in greater recognition of cardiac amyloidosis (CA) in everyday clinical practice, but the diagnosis continues to be made in patients with late stage disease, suggesting that more needs to be done to improve awareness of its clinical manifestations and the potential of therapeutic intervention to improve prognosis. Light chain CA (AL-CA) in particular, if recognized early and treated with targeted plasma cell therapy, can be managed very effectively. For patients with transthyretin amyloidosis, there are numerous therapies that are currently in late phase clinical trials. In this review we address common questions encountered in clinical practice regarding etiology, clinical presentation, diagnosis and management of cardiac amyloidosis, focusing on recent important developments in cardiac imaging and biochemical diagnosis. The aim is to show how a systematic approach to the evaluation of suspected CA can impact the prognosis of patients in the modern era. PMID:28373528

  14. In vivo imaging of the Drosophila Melanogaster heart using a novel optical coherence tomography microscope

    NASA Astrophysics Data System (ADS)

    Izatt, Susan D.; Choma, Michael A.; Israel, Steven; Wessells, Robert J.; Bodmer, Rolf; Izatt, Joseph A.

    2005-03-01

    Real time in vivo optical coherence tomography (OCT) imaging of the adult fruit fly Drosophila melanogaster heart using a newly designed OCT microscope allows accurate assessment of cardiac anatomy and function. D. melanogaster has been used extensively in genetic research for over a century, but in vivo evaluation of the heart has been limited by available imaging technology. The ability to assess phenotypic changes with micrometer-scale resolution noninvasively in genetic models such as D. melanogaster is needed in the advancing fields of developmental biology and genetics. We have developed a dedicated small animal OCT imaging system incorporating a state-of-the-art, real time OCT scanner integrated into a standard stereo zoom microscope which allows for simultaneous OCT and video imaging. System capabilities include A-scan, B-scan, and M-scan imaging as well as automated 3D volumetric acquisition and visualization. Transverse and sagittal B-mode scans of the four chambered D. melanogaster heart have been obtained with the OCT microscope and are consistent with detailed anatomical studies from the literature. Further analysis by M-mode scanning is currently under way to assess cardiac function as a function of age and sex by determination of shortening fraction and ejection fraction. These studies create control cardiac data on the wild type D. melanogaster, allowing subsequent evaluation of phenotypic cardiac changes in this model after regulated genetic mutation.

  15. XD-GRASP: Golden-angle radial MRI with reconstruction of extra motion-state dimensions using compressed sensing.

    PubMed

    Feng, Li; Axel, Leon; Chandarana, Hersh; Block, Kai Tobias; Sodickson, Daniel K; Otazo, Ricardo

    2016-02-01

    To develop a novel framework for free-breathing MRI called XD-GRASP, which sorts dynamic data into extra motion-state dimensions using the self-navigation properties of radial imaging and reconstructs the multidimensional dataset using compressed sensing. Radial k-space data are continuously acquired using the golden-angle sampling scheme and sorted into multiple motion-states based on respiratory and/or cardiac motion signals derived directly from the data. The resulting undersampled multidimensional dataset is reconstructed using a compressed sensing approach that exploits sparsity along the new dynamic dimensions. The performance of XD-GRASP is demonstrated for free-breathing three-dimensional (3D) abdominal imaging, two-dimensional (2D) cardiac cine imaging and 3D dynamic contrast-enhanced (DCE) MRI of the liver, comparing against reconstructions without motion sorting in both healthy volunteers and patients. XD-GRASP separates respiratory motion from cardiac motion in cardiac imaging, and respiratory motion from contrast enhancement in liver DCE-MRI, which improves image quality and reduces motion-blurring artifacts. XD-GRASP represents a new use of sparsity for motion compensation and a novel way to handle motions in the context of a continuous acquisition paradigm. Instead of removing or correcting motion, extra motion-state dimensions are reconstructed, which improves image quality and also offers new physiological information of potential clinical value. © 2015 Wiley Periodicals, Inc.

  16. XD-GRASP: Golden-Angle Radial MRI with Reconstruction of Extra Motion-State Dimensions Using Compressed Sensing

    PubMed Central

    Feng, Li; Axel, Leon; Chandarana, Hersh; Block, Kai Tobias; Sodickson, Daniel K.; Otazo, Ricardo

    2015-01-01

    Purpose To develop a novel framework for free-breathing MRI called XD-GRASP, which sorts dynamic data into extra motion-state dimensions using the self-navigation properties of radial imaging and reconstructs the multidimensional dataset using compressed sensing. Methods Radial k-space data are continuously acquired using the golden-angle sampling scheme and sorted into multiple motion-states based on respiratory and/or cardiac motion signals derived directly from the data. The resulting under-sampled multidimensional dataset is reconstructed using a compressed sensing approach that exploits sparsity along the new dynamic dimensions. The performance of XD-GRASP is demonstrated for free-breathing three-dimensional (3D) abdominal imaging, two-dimensional (2D) cardiac cine imaging and 3D dynamic contrast-enhanced (DCE) MRI of the liver, comparing against reconstructions without motion sorting in both healthy volunteers and patients. Results XD-GRASP separates respiratory motion from cardiac motion in cardiac imaging, and respiratory motion from contrast enhancement in liver DCE-MRI, which improves image quality and reduces motion-blurring artifacts. Conclusion XD-GRASP represents a new use of sparsity for motion compensation and a novel way to handle motions in the context of a continuous acquisition paradigm. Instead of removing or correcting motion, extra motion-state dimensions are reconstructed, which improves image quality and also offers new physiological information of potential clinical value. PMID:25809847

  17. Automated Segmentation of Light-Sheet Fluorescent Imaging to Characterize Experimental Doxorubicin-Induced Cardiac Injury and Repair.

    PubMed

    Packard, René R Sevag; Baek, Kyung In; Beebe, Tyler; Jen, Nelson; Ding, Yichen; Shi, Feng; Fei, Peng; Kang, Bong Jin; Chen, Po-Heng; Gau, Jonathan; Chen, Michael; Tang, Jonathan Y; Shih, Yu-Huan; Ding, Yonghe; Li, Debiao; Xu, Xiaolei; Hsiai, Tzung K

    2017-08-17

    This study sought to develop an automated segmentation approach based on histogram analysis of raw axial images acquired by light-sheet fluorescent imaging (LSFI) to establish rapid reconstruction of the 3-D zebrafish cardiac architecture in response to doxorubicin-induced injury and repair. Input images underwent a 4-step automated image segmentation process consisting of stationary noise removal, histogram equalization, adaptive thresholding, and image fusion followed by 3-D reconstruction. We applied this method to 3-month old zebrafish injected intraperitoneally with doxorubicin followed by LSFI at 3, 30, and 60 days post-injection. We observed an initial decrease in myocardial and endocardial cavity volumes at day 3, followed by ventricular remodeling at day 30, and recovery at day 60 (P < 0.05, n = 7-19). Doxorubicin-injected fish developed ventricular diastolic dysfunction and worsening global cardiac function evidenced by elevated E/A ratios and myocardial performance indexes quantified by pulsed-wave Doppler ultrasound at day 30, followed by normalization at day 60 (P < 0.05, n = 9-20). Treatment with the γ-secretase inhibitor, DAPT, to inhibit cleavage and release of Notch Intracellular Domain (NICD) blocked cardiac architectural regeneration and restoration of ventricular function at day 60 (P < 0.05, n = 6-14). Our approach provides a high-throughput model with translational implications for drug discovery and genetic modifiers of chemotherapy-induced cardiomyopathy.

  18. Effect of respiratory and cardiac gating on the major diffusion-imaging metrics

    PubMed Central

    Hamaguchi, Hiroyuki; Sugimori, Hiroyuki; Nakanishi, Mitsuhiro; Nakagawa, Shin; Fujiwara, Taro; Yoshida, Hirokazu; Takamori, Sayaka; Shirato, Hiroki

    2016-01-01

    The effect of respiratory gating on the major diffusion-imaging metrics and that of cardiac gating on mean kurtosis (MK) are not known. For evaluation of whether the major diffusion-imaging metrics—MK, fractional anisotropy (FA), and mean diffusivity (MD) of the brain—varied between gated and non-gated acquisitions, respiratory-gated, cardiac-gated, and non-gated diffusion-imaging of the brain were performed in 10 healthy volunteers. MK, FA, and MD maps were constructed for all acquisitions, and the histograms were constructed. The normalized peak height and location of the histograms were compared among the acquisitions by use of Friedman and post hoc Wilcoxon tests. The effect of the repetition time (TR) on the diffusion-imaging metrics was also tested, and we corrected for its variation among acquisitions, if necessary. The results showed a shift in the peak location of the MK and MD histograms to the right with an increase in TR (p ≤ 0.01). The corrected peak location of the MK histograms, the normalized peak height of the FA histograms, the normalized peak height and the corrected peak location of the MD histograms varied significantly between the gated and non-gated acquisitions (p < 0.05). These results imply an influence of respiration and cardiac pulsation on the major diffusion-imaging metrics. The gating conditions must be kept identical if reproducible results are to be achieved. PMID:27073115

  19. Imaging system for cardiac planar imaging using a dedicated dual-head gamma camera

    DOEpatents

    Majewski, Stanislaw [Morgantown, VA; Umeno, Marc M [Woodinville, WA

    2011-09-13

    A cardiac imaging system employing dual gamma imaging heads co-registered with one another to provide two dynamic simultaneous views of the heart sector of a patient torso. A first gamma imaging head is positioned in a first orientation with respect to the heart sector and a second gamma imaging head is positioned in a second orientation with respect to the heart sector. An adjustment arrangement is capable of adjusting the distance between the separate imaging heads and the angle between the heads. With the angle between the imaging heads set to 180 degrees and operating in a range of 140-159 keV and at a rate of up to 500kHz, the imaging heads are co-registered to produce simultaneous dynamic recording of two stereotactic views of the heart. The use of co-registered imaging heads maximizes the uniformity of detection sensitivity of blood flow in and around the heart over the whole heart volume and minimizes radiation absorption effects. A normalization/image fusion technique is implemented pixel-by-corresponding pixel to increase signal for any cardiac region viewed in two images obtained from the two opposed detector heads for the same time bin. The imaging system is capable of producing enhanced first pass studies, bloodpool studies including planar, gated and non-gated EKG studies, planar EKG perfusion studies, and planar hot spot imaging.

  20. Impaired atrioventricular transport in patients with transposition of the great arteries palliated by atrial switch and preserved systolic right ventricular function: A magnetic resonance imaging study.

    PubMed

    Ladouceur, Magalie; Kachenoura, Nadjia; Soulat, Gilles; Bollache, Emilie; Redheuil, Alban; Azizi, Michel; Delclaux, Christophe; Chatellier, Gilles; Boutouyrie, Pierre; Iserin, Laurence; Bonnet, Damien; Mousseaux, Elie

    2017-07-01

    We aimed (1) determine if systemic right ventricle filling parameters influence systemic right ventricle stroke volume in adult patients with D-transposition of the great arteries (D-TGA) palliated by atrial switch, using cardiac magnetic resonance imaging and echocardiography, and (2) to study relationship of these diastolic parameters with exercise performance and BNP, in patients with preserved systolic systemic right ventricle function. Single-center, cross-sectional, prospective study. In patients with D-TGA palliated by atrial switch, diastolic dysfunction of the systemic right ventricle may precede systolic dysfunction. Forty-five patients with D-TGA and atrial switch and 45 age and sex-matched healthy subjects underwent cardiac magnetic resonance imaging and echocardiography. Filling flow-rates measured by phase-contrast cardiac magnetic resonance imaging were analyzed using customized software to estimate diastolic parameters and compared with exercise performance. In D-TGA, early filling of systemic right ventricle was impaired with a lower peak filling rate normalized by filling volume (Ef/FV measured by cardiac magnetic resonance imaging) and a higher early filling peak velocity normalized by early peak myocardial velocity (E US /Ea measured by echocardiography) compared with controls (P ≤ .04). Stroke volume of systemic right ventricle showed a direct and significant association with pulmonary venous pathway size (respectively r = 0.50, P < .01). Systemic right atrial area and systemic right ventricle mass/volume index measured by cardiac magnetic resonance imaging, as well as Ef/FV were significantly correlated with exercise performances and BNP (P < .01). All correlations were independent of age, gender, body mass index and blood pressure. Systemic right ventricle pre-load and stroke volume depend mainly on intraatrial pathway function. Moreover, systemic right ventricle remodeling and right atrial dysfunction impair systemic right ventricle filling, leading to BNP increase and exercise limitation. Cardiac magnetic resonance imaging should assess systemic right ventricle filling abnormalities in D-TGA patients. © 2017 Wiley Periodicals, Inc.

  1. Establishing a clinical cardiac MRI service.

    PubMed

    O'Regan, D P; Schmitz, S A

    2006-03-01

    After several years of research development cardiovascular MRI has evolved into a widely accepted clinical tool. It offers important diagnostic and prognostic information for a variety of clinical indications, which include ischaemic heart disease, cardiomyopathies, valvular dysfunction and congenital heart disorders. It is a safe non-invasive technique that employs a variety of imaging sequences optimized for temporal or spatial resolution, tissue-specific contrast, flow quantification or angiography. Cardiac MRI offers specific advantages over conventional imaging techniques for a significant number of patients. The demand for cardiac MRI studies from cardiothoracic surgeons, cardiologists and other referrers is likely to continue to rise with pressure for more widespread local service provision. Setting up a cardiac MRI service requires careful consideration regarding funding issues and how it will be integrated with existing service provision. The purchase of cardiac phased array coils, monitoring equipment and software upgrades must also be considered, as well as the training needs of those involved. The choice of appropriate imaging protocols will be guided by operator experience, clinical indication and equipment capability, and is likely to evolve as the service develops. Post-processing and offline analysis form a significant part of the time taken to report studies and an efficient method of providing quantitative reports is an important requirement. Collaboration between radiologists and cardiologists is needed to develop a successful service and multi-disciplinary meetings are key component of this. This review will explore these issues from our perspective of a new clinical cardiac MRI service operating over its first year in a teaching hospital imaging department.

  2. Cardiac Magnetic Resonance Imaging Using an Open 1.0T MR Platform: A Comparative Study with a 1.5T Tunnel System.

    PubMed

    Fischbach, Katharina; Kosiek, Otrud; Friebe, Björn; Wybranski, Christian; Schnackenburg, Bernhard; Schmeisser, Alexander; Smid, Jan; Ricke, Jens; Pech, Maciej

    2017-01-01

    Cardiac magnetic resonance imaging (cMRI) has become the non-invasive reference standard for the evaluation of cardiac function and viability. The introduction of open, high-field, 1.0T (HFO) MR scanners offers advantages for examinations of obese, claustrophobic and paediatric patients.The aim of our study was to compare standard cMRI sequences from an HFO scanner and those from a cylindrical, 1.5T MR system. Fifteen volunteers underwent cMRI both in an open HFO and in a cylindrical MR system. The protocol consisted of cine and unenhanced tissue sequences. The signal-to-noise ratio (SNR) for each sequence and blood-myocardium contrast for the cine sequences were assessed. Image quality and artefacts were rated. The location and number of non-diagnostic segments was determined. Volunteers' tolerance to examinations in both scanners was investigated. SNR was significantly lower in the HFO scanner (all p<0.001). However, the contrast of the cine sequence was significantly higher in the HFO platform compared to the 1.5T MR scanner (0.685±0.41 vs. 0.611±0.54; p<0.001). Image quality was comparable for all sequences (all p>0.05). Overall, only few non-diagnostic myocardial segments were recorded: 6/960 (0.6%) by the HFO and 17/960 (1.8%) segments by the cylindrical system. The volunteers expressed a preference for the open MR system (p<0.01). Standard cardiac MRI sequences in an HFO platform offer a high image quality that is comparable to the quality of images acquired in a cylindrical 1.5T MR scanner. An open scanner design may potentially improve tolerance of cardiac MRI and therefore allow to examine an even broader patient spectrum.

  3. A 128-channel receive-only cardiac coil for highly accelerated cardiac MRI at 3 Tesla.

    PubMed

    Schmitt, Melanie; Potthast, Andreas; Sosnovik, David E; Polimeni, Jonathan R; Wiggins, Graham C; Triantafyllou, Christina; Wald, Lawrence L

    2008-06-01

    A 128-channel receive-only array coil is described and tested for cardiac imaging at 3T. The coil is closely contoured to the body with a "clam-shell" geometry with 68 posterior and 60 anterior elements, each 75 mm in diameter, and arranged in a continuous overlapped array of hexagonal symmetry to minimize nearest neighbor coupling. Signal-to-noise ratio (SNR) and noise amplification for parallel imaging (G-factor) were evaluated in phantom and volunteer experiments. These results were compared to those of commercially available 24-channel and 32-channel coils in routine use for cardiac imaging. The in vivo measurements with the 128-channel coil resulted in SNR gains compared to the 24-channel coil (up to 2.2-fold in the apex). The 128- and 32-channel coils showed similar SNR in the heart, likely dominated by the similar element diameters of these coils. The maximum G-factor values were up to seven times better for a seven-fold acceleration factor (R=7) compared to the 24-channel coil and up to two-fold improved compared to the 32-channel coil. The ability of the 128-channel coil to facilitate highly accelerated cardiac imaging was demonstrated in four volunteers using acceleration factors up to seven-fold (R=7) in a single spatial dimension. Copyright (c) 2008 Wiley-Liss, Inc.

  4. Creation of an ensemble of simulated cardiac cases and a human observer study: tools for the development of numerical observers for SPECT myocardial perfusion imaging

    NASA Astrophysics Data System (ADS)

    O'Connor, J. Michael; Pretorius, P. Hendrik; Gifford, Howard C.; Licho, Robert; Joffe, Samuel; McGuiness, Matthew; Mehurg, Shannon; Zacharias, Michael; Brankov, Jovan G.

    2012-02-01

    Our previous Single Photon Emission Computed Tomography (SPECT) myocardial perfusion imaging (MPI) research explored the utility of numerical observers. We recently created two hundred and eighty simulated SPECT cardiac cases using Dynamic MCAT (DMCAT) and SIMIND Monte Carlo tools. All simulated cases were then processed with two reconstruction methods: iterative ordered subset expectation maximization (OSEM) and filtered back-projection (FBP). Observer study sets were assembled for both OSEM and FBP methods. Five physicians performed an observer study on one hundred and seventy-nine images from the simulated cases. The observer task was to indicate detection of any myocardial perfusion defect using the American Society of Nuclear Cardiology (ASNC) 17-segment cardiac model and the ASNC five-scale rating guidelines. Human observer Receiver Operating Characteristic (ROC) studies established the guidelines for the subsequent evaluation of numerical model observer (NO) performance. Several NOs were formulated and their performance was compared with the human observer performance. One type of NO was based on evaluation of a cardiac polar map that had been pre-processed using a gradient-magnitude watershed segmentation algorithm. The second type of NO was also based on analysis of a cardiac polar map but with use of a priori calculated average image derived from an ensemble of normal cases.

  5. Improvement of cardiac CT reconstruction using local motion vector fields.

    PubMed

    Schirra, Carsten Oliver; Bontus, Claas; van Stevendaal, Udo; Dössel, Olaf; Grass, Michael

    2009-03-01

    The motion of the heart is a major challenge for cardiac imaging using CT. A novel approach to decrease motion blur and to improve the signal to noise ratio is motion compensated reconstruction which takes motion vector fields into account in order to correct motion. The presented work deals with the determination of local motion vector fields from high contrast objects and their utilization within motion compensated filtered back projection reconstruction. Image registration is applied during the quiescent cardiac phases. Temporal interpolation in parameter space is used in order to estimate motion during strong motion phases. The resulting motion vector fields are during image reconstruction. The method is assessed using a software phantom and several clinical cases for calcium scoring. As a criterion for reconstruction quality, calcium volume scores were derived from both, gated cardiac reconstruction and motion compensated reconstruction throughout the cardiac phases using low pitch helical cone beam CT acquisitions. The presented technique is a robust method to determine and utilize local motion vector fields. Motion compensated reconstruction using the derived motion vector fields leads to superior image quality compared to gated reconstruction. As a result, the gating window can be enlarged significantly, resulting in increased SNR, while reliable Hounsfield units are achieved due to the reduced level of motion artefacts. The enlargement of the gating window can be translated into reduced dose requirements.

  6. Role of radionuclide imaging for diagnosis of device and prosthetic valve infections

    PubMed Central

    Sarrazin, Jean-François; Philippon, François; Trottier, Mikaël; Tessier, Michel

    2016-01-01

    Cardiovascular implantable electronic device (CIED) infection and prosthetic valve endocarditis (PVE) remain a diagnostic challenge. Cardiac imaging plays an important role in the diagnosis and management of patients with CIED infection or PVE. Over the past few years, cardiac radionuclide imaging has gained a key role in the diagnosis of these patients, and in assessing the need for surgery, mainly in the most difficult cases. Both 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) and radiolabelled white blood cell single-photon emission computed tomography/computed tomography (WBC SPECT/CT) have been studied in these situations. In their 2015 guidelines for the management of infective endocarditis, the European Society of Cardiology incorporated cardiac nuclear imaging as part of their diagnostic algorithm for PVE, but not CIED infection since the data were judged insufficient at the moment. This article reviews the actual knowledge and recent studies on the use of 18F-FDG PET/CT and WBC SPECT/CT in the context of CIED infection and PVE, and describes the technical aspects of cardiac radionuclide imaging. It also discusses their accepted and potential indications for the diagnosis and management of CIED infection and PVE, the limitations of these tests, and potential areas of future research. PMID:27721936

  7. Automatic cardiac LV segmentation in MRI using modified graph cuts with smoothness and interslice constraints.

    PubMed

    Albà, Xènia; Figueras I Ventura, Rosa M; Lekadir, Karim; Tobon-Gomez, Catalina; Hoogendoorn, Corné; Frangi, Alejandro F

    2014-12-01

    Magnetic resonance imaging (MRI), specifically late-enhanced MRI, is the standard clinical imaging protocol to assess cardiac viability. Segmentation of myocardial walls is a prerequisite for this assessment. Automatic and robust multisequence segmentation is required to support processing massive quantities of data. A generic rule-based framework to automatically segment the left ventricle myocardium is presented here. We use intensity information, and include shape and interslice smoothness constraints, providing robustness to subject- and study-specific changes. Our automatic initialization considers the geometrical and appearance properties of the left ventricle, as well as interslice information. The segmentation algorithm uses a decoupled, modified graph cut approach with control points, providing a good balance between flexibility and robustness. The method was evaluated on late-enhanced MRI images from a 20-patient in-house database, and on cine-MRI images from a 15-patient open access database, both using as reference manually delineated contours. Segmentation agreement, measured using the Dice coefficient, was 0.81±0.05 and 0.92±0.04 for late-enhanced MRI and cine-MRI, respectively. The method was also compared favorably to a three-dimensional Active Shape Model approach. The experimental validation with two magnetic resonance sequences demonstrates increased accuracy and versatility. © 2013 Wiley Periodicals, Inc.

  8. Contactless physiological signals extraction based on skin color magnification

    NASA Astrophysics Data System (ADS)

    Suh, Kun Ha; Lee, Eui Chul

    2017-11-01

    Although the human visual system is not sufficiently sensitive to perceive blood circulation, blood flow caused by cardiac activity makes slight changes on human skin surfaces. With advances in imaging technology, it has become possible to capture these changes through digital cameras. However, it is difficult to obtain clear physiological signals from such changes due to its fineness and noise factors, such as motion artifacts and camera sensing disturbances. We propose a method for extracting physiological signals with improved quality from skin colored-videos recorded with a remote RGB camera. The results showed that our skin color magnification method reveals the hidden physiological components remarkably in the time-series signal. A Korea Food and Drug Administration-approved heart rate monitor was used for verifying the resulting signal synchronized with the actual cardiac pulse, and comparisons of signal peaks showed correlation coefficients of almost 1.0. In particular, our method can be an effective preprocessing before applying additional postfiltering techniques to improve accuracy in image-based physiological signal extractions.

  9. In Situ Optical Mapping of Voltage and Calcium in the Heart

    PubMed Central

    Ewart, Paul; Ashley, Euan A.; Loew, Leslie M.; Kohl, Peter; Bollensdorff, Christian; Woods, Christopher E.

    2012-01-01

    Electroanatomic mapping the interrelation of intracardiac electrical activation with anatomic locations has become an important tool for clinical assessment of complex arrhythmias. Optical mapping of cardiac electrophysiology combines high spatiotemporal resolution of anatomy and physiological function with fast and simultaneous data acquisition. If applied to the clinical setting, this could improve both diagnostic potential and therapeutic efficacy of clinical arrhythmia interventions. The aim of this study was to explore this utility in vivo using a rat model. To this aim, we present a single-camera imaging and multiple light-emitting-diode illumination system that reduces economic and technical implementation hurdles to cardiac optical mapping. Combined with a red-shifted calcium dye and a new near-infrared voltage-sensitive dye, both suitable for use in blood-perfused tissue, we demonstrate the feasibility of in vivo multi-parametric imaging of the mammalian heart. Our approach combines recording of electrophysiologically-relevant parameters with observation of structural substrates and is adaptable, in principle, to trans-catheter percutaneous approaches. PMID:22876327

  10. Recent developments of cyclotron produced radionuclides for nuclear cardiology

    NASA Astrophysics Data System (ADS)

    Kulkarni, P. V.; Jansen, D. E.; Corbett, J. R.

    1987-04-01

    For over a decade myocardial perfusion imaging with thallium-201, a cyclotron product, has been routinely used in clinical medicine. Recent advances have allowed the efficient production of very high purity (> 99.8%) iodine-123. New metabolically active 123I labeled radiopharmaceuticals, including alkyl and phenyl fatty acids, and norepinephrine analogs, have been developed and are undergoing clinical trials. Fab' fragments of monoclonal antibodies to cardiac myosin have been labeled with indium-111 ( 111In) and are undergoing clinical evaluation for imaging myocardial infarcts. Monoclonal antibodies to platelets, fibrin, and the thrombolytic agent, tissue plasminogen activator (TPA), have recently been labeled with 111In. Together these developments in radiotracers and instrumentation should have a significant impact on the future of cardiovascular nuclear medicine. This manuscript will discuss developments in single photon emitting radiotracers for myocardial imaging.

  11. Evaluation of pleural and pericardial effusions by magnetic resonance imaging.

    PubMed

    Tscholakoff, D; Sechtem, U; de Geer, G; Schmidt, H; Higgins, C B

    1987-08-01

    MR examinations of 36 patients with pleural and/or pericardial effusions were retrospectively evaluated. The purpose of this study was to determine of MR imaging is capable of differentiating between pleural and pericardial effusions of different compositions using standard electrocardiogram (ECG)-gated and non-gated spin echo pulse sequences. Additional data was obtained from experimental pleural effusions in 10 dogs. The results of this study indicate that old hemorrhages into the pleural or pericardial space can be differentiated from other pleural or pericardial effusions. However, further differentiation between transudates, exudates and sanguinous effusions is not possible on MR images acquired with standard spin echo pulse sequences. Respiratory and cardiac motion are responsible for signal loss, particularly on first echo images. This was documented in experiments in dogs with induced effusions of known composition; "negative" T2 values consistent with fluid motion during imaging sequences were observed in 80% of cases. However, postmortem studies of the dogs with experimental effusions showed differences between effusions with low protein concentrations and higher protein concentrations. We conclude from our study that characterization of pleural and pericardial effusions on standard ECG-gated and non-gated MR examinations is limited to the positive identification of hemorrhage. Motion of the fluid due to cardiac and respiratory activity causes artifactual and unpredictable changes in intensity values negating the more subtle differences in intensity associated with increasing protein content.

  12. [Evaluation of cardiac tumors by multidetector computed tomography and magnetic resonance imaging].

    PubMed

    Mercado-Guzman, Marcela P; Meléndez-Ramírez, Gabriela; Castillo-Castellon, Francisco; Kimura-Hayama, Eric

    Cardiac tumors, are a rare pathology (0.002-0.3%) in all age groups, however, they have a clinic importance, due the affected organ. They are classified in primary (benign or malignant) and secondary (metastasis) types. Among primary type, mixoma, is the most common benign tumor, and sarcoma represents most of the malignant injuries. Cardiac metastasis are more frequent than primary tumors. Clinic effects of cardiac tumors are unspecific and vary according their location, size and agresivity. The use of Multidetector Computed Tomography (MDCT) and Magnetic Resonance Imaging (MRI) assist on the location, sizing, anatomical relationships and the compromise of adyacents structures, besides, MRI is useful for tissue characterization of the tumor. Due to the previous reasons, studies based on noninvasive cardiovascular imaging, have an important role on the characterization of these lesions and the differential diagnosis among them. Copyright © 2016 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  13. Cerebrospinal fluid bulk flow is driven by the cardiac cycle

    NASA Astrophysics Data System (ADS)

    Tithof, Jeffrey; Mestre, Humberto; Thomas, John; Nedergaard, Maiken; Kelley, Douglas

    2017-11-01

    Recent discoveries have uncovered a cerebrospinal fluid (CSF) transport system in the perivascular spaces (PVS) of the mammalian brain which clears excess extracellular fluid and protein waste products. The oscillatory pattern of CSF flow has long been attributed to arterial pulsations due to cardiac contractility but limitations in imaging techniques have impeded quantitative measurement of flow rates within the PVS. In this talk, we describe quantitative measurements from the first ever direct imaging of CSF flow in the PVS of a mouse brain. We perform particle tracking velocimetry to obtain time-resolved velocity measurements. To identify the cardiac and/or respiratory dependence of the flow, while imaging, we simultaneously record the mouse's electrocardiogram and respiration. Our measurements conclusively indicate that CSF pulsatility in the arterial PVS is directly driven by the cardiac cycle and not by the respiratory cycle or cerebral vasomotion. These results offer a substantial step forward in understanding bulk flow of CSF in the mammalian brain and may have important implications related to neurodegenerative diseases.

  14. Fast interactive real-time volume rendering of real-time three-dimensional echocardiography: an implementation for low-end computers

    NASA Technical Reports Server (NTRS)

    Saracino, G.; Greenberg, N. L.; Shiota, T.; Corsi, C.; Lamberti, C.; Thomas, J. D.

    2002-01-01

    Real-time three-dimensional echocardiography (RT3DE) is an innovative cardiac imaging modality. However, partly due to lack of user-friendly software, RT3DE has not been widely accepted as a clinical tool. The object of this study was to develop and implement a fast and interactive volume renderer of RT3DE datasets designed for a clinical environment where speed and simplicity are not secondary to accuracy. Thirty-six patients (20 regurgitation, 8 normal, 8 cardiomyopathy) were imaged using RT3DE. Using our newly developed software, all 3D data sets were rendered in real-time throughout the cardiac cycle and assessment of cardiac function and pathology was performed for each case. The real-time interactive volume visualization system is user friendly and instantly provides consistent and reliable 3D images without expensive workstations or dedicated hardware. We believe that this novel tool can be used clinically for dynamic visualization of cardiac anatomy.

  15. Dual lumen transducer probes for real-time 3-D interventional cardiac ultrasound.

    PubMed

    Lee, Warren; Idriss, Salim F; Wolf, Patrick D; Smith, Stephen W

    2003-09-01

    We have developed dual lumen probes incorporating a forward-viewing matrix array transducer with an integrated working lumen for delivery of tools in real-time 3-D (RT3-D) interventional echocardiography. The probes are of 14 Fr and 22 Fr sizes, with 112 channel 2-D arrays operating at 5 MHz. We obtained images of cardiac anatomy and simultaneous interventional device delivery with an in vivo sheep model, including: manipulation of a 0.36-mm diameter guidewire into the coronary sinus, guidance of a transseptal puncture using a 1.2-mm diameter Brockenbrough needle, and guidance of a right ventricular biopsy using 3 Fr biopsy forceps. We have also incorporated the 22 Fr probe within a 6-mm surgical trocar to obtain apical four-chamber ultrasound (US) scans from a subcostal position. Combining the imaging catheter with a working lumen in a single device may simplify cardiac interventional procedures by allowing clinicians to easily visualize cardiac structures and simultaneously direct interventional tools in a RT3-D image.

  16. Left Ventricular Endocardium Tracking by Fusion of Biomechanical and Deformable Models

    PubMed Central

    Gu, Jason

    2014-01-01

    This paper presents a framework for tracking left ventricular (LV) endocardium through 2D echocardiography image sequence. The framework is based on fusion of biomechanical (BM) model of the heart with the parametric deformable model. The BM model constitutive equation consists of passive and active strain energy functions. The deformations of the LV are obtained by solving the constitutive equations using ABAQUS FEM in each frame in the cardiac cycle. The strain energy functions are defined in two user subroutines for active and passive phases. Average fusion technique is used to fuse the BM and deformable model contours. Experimental results are conducted to verify the detected contours and the results are evaluated by comparing themto a created gold standard. The results and the evaluation proved that the framework has the tremendous potential to track and segment the LV through the whole cardiac cycle. PMID:24587814

  17. Brucellosis With Multi-Organ Involvement in a Patient With History of Composite Aortic Graft and Hepatitis B.

    PubMed

    Dehghan Manshadi, Seyed Ali; Rezahosseini, Omid; Abdi Liaei, Zahra

    2016-11-01

    The brucellosis with multi-organ involvement in a patient with a history of the composite aortic graft (Bentall procedure) and Hepatitis B infection is rare. A 35-year-old man presented to us with fever and loss of consciousness. Four years ago, he was IDU and underwent cardiac surgery because of endocarditis. Recently lumbar spondylodiscitis was diagnosed. The Wright (1/320) and Coombs Wright tests (1/640) were positive. After CNS imaging, lumbar puncture was done. The CSF pleocytosis was lymphocyte dominant. In cardiac echocardiography, large vegetation on prosthetic aortic valve leaflets was seen. The brain MRI was reported abnormal. Treatment of brucellosis started with Ceftriaxone, Doxycycline, Rifampin and Gentamycin. After 4 days, he became oriented, and fever was disappeared then we continued the treatment for 16 days. The patient discharged and followed by daily phone calls. As symptoms of abdominal pain and jaundice were presented on the fifth day, he re-admitted. The patient expired because of hepatorenal and cardiac insufficiency. Drug side effects, activation of Hepatitis B and embolism of cardiac vegetation to other organs were suspected causes of death. We do not suggest medical therapy without cardiac surgery in such cases. When combination therapy is necessary for brucellosis in an HBsAg-positive patient, hepatitis virus activity should be assess by HBV-DNA PCR and the dose of drugs with known hepatotoxic effects such as rifampin and co-trimoxazole should be adjust. Combination therapy with quinolones instead of hepatoxic drugs is one of our suggustions.

  18. Patient-specific cardiac phantom for clinical training and preprocedure surgical planning.

    PubMed

    Laing, Justin; Moore, John; Vassallo, Reid; Bainbridge, Daniel; Drangova, Maria; Peters, Terry

    2018-04-01

    Minimally invasive mitral valve repair procedures including MitraClip ® are becoming increasingly common. For cases of complex or diseased anatomy, clinicians may benefit from using a patient-specific cardiac phantom for training, surgical planning, and the validation of devices or techniques. An imaging compatible cardiac phantom was developed to simulate a MitraClip ® procedure. The phantom contained a patient-specific cardiac model manufactured using tissue mimicking materials. To evaluate accuracy, the patient-specific model was imaged using computed tomography (CT), segmented, and the resulting point cloud dataset was compared using absolute distance to the original patient data. The result, when comparing the molded model point cloud to the original dataset, resulted in a maximum Euclidean distance error of 7.7 mm, an average error of 0.98 mm, and a standard deviation of 0.91 mm. The phantom was validated using a MitraClip ® device to ensure anatomical features and tools are identifiable under image guidance. Patient-specific cardiac phantoms may allow for surgical complications to be accounted for preoperative planning. The information gained by clinicians involved in planning and performing the procedure should lead to shorter procedural times and better outcomes for patients.

  19. Higher-Order Motion-Compensation for In Vivo Cardiac Diffusion Tensor Imaging in Rats

    PubMed Central

    Welsh, Christopher L.; DiBella, Edward V. R.; Hsu, Edward W.

    2015-01-01

    Motion of the heart has complicated in vivo applications of cardiac diffusion MRI and diffusion tensor imaging (DTI), especially in small animals such as rats where ultra-high-performance gradient sets are currently not available. Even with velocity compensation via, for example, bipolar encoding pulses, the variable shot-to-shot residual motion-induced spin phase can still give rise to pronounced artifacts. This study presents diffusion-encoding schemes that are designed to compensate for higher-order motion components, including acceleration and jerk, which also have the desirable practical features of minimal TEs and high achievable b-values. The effectiveness of these schemes was verified numerically on a realistic beating heart phantom, and demonstrated empirically with in vivo cardiac diffusion MRI in rats. Compensation for acceleration, and lower motion components, was found to be both necessary and sufficient for obtaining diffusion-weighted images of acceptable quality and SNR, which yielded the first in vivo cardiac DTI demonstrated in the rat. These findings suggest that compensation for higher order motion, particularly acceleration, can be an effective alternative solution to high-performance gradient hardware for improving in vivo cardiac DTI. PMID:25775486

  20. Integrating light-sheet imaging with virtual reality to recapitulate developmental cardiac mechanics.

    PubMed

    Ding, Yichen; Abiri, Arash; Abiri, Parinaz; Li, Shuoran; Chang, Chih-Chiang; Baek, Kyung In; Hsu, Jeffrey J; Sideris, Elias; Li, Yilei; Lee, Juhyun; Segura, Tatiana; Nguyen, Thao P; Bui, Alexander; Sevag Packard, René R; Fei, Peng; Hsiai, Tzung K

    2017-11-16

    Currently, there is a limited ability to interactively study developmental cardiac mechanics and physiology. We therefore combined light-sheet fluorescence microscopy (LSFM) with virtual reality (VR) to provide a hybrid platform for 3D architecture and time-dependent cardiac contractile function characterization. By taking advantage of the rapid acquisition, high axial resolution, low phototoxicity, and high fidelity in 3D and 4D (3D spatial + 1D time or spectra), this VR-LSFM hybrid methodology enables interactive visualization and quantification otherwise not available by conventional methods, such as routine optical microscopes. We hereby demonstrate multiscale applicability of VR-LSFM to (a) interrogate skin fibroblasts interacting with a hyaluronic acid-based hydrogel, (b) navigate through the endocardial trabecular network during zebrafish development, and (c) localize gene therapy-mediated potassium channel expression in adult murine hearts. We further combined our batch intensity normalized segmentation algorithm with deformable image registration to interface a VR environment with imaging computation for the analysis of cardiac contraction. Thus, the VR-LSFM hybrid platform demonstrates an efficient and robust framework for creating a user-directed microenvironment in which we uncovered developmental cardiac mechanics and physiology with high spatiotemporal resolution.

  1. Integrating light-sheet imaging with virtual reality to recapitulate developmental cardiac mechanics

    PubMed Central

    Ding, Yichen; Abiri, Arash; Abiri, Parinaz; Li, Shuoran; Chang, Chih-Chiang; Hsu, Jeffrey J.; Sideris, Elias; Li, Yilei; Lee, Juhyun; Segura, Tatiana; Nguyen, Thao P.; Bui, Alexander; Sevag Packard, René R.; Hsiai, Tzung K.

    2017-01-01

    Currently, there is a limited ability to interactively study developmental cardiac mechanics and physiology. We therefore combined light-sheet fluorescence microscopy (LSFM) with virtual reality (VR) to provide a hybrid platform for 3D architecture and time-dependent cardiac contractile function characterization. By taking advantage of the rapid acquisition, high axial resolution, low phototoxicity, and high fidelity in 3D and 4D (3D spatial + 1D time or spectra), this VR-LSFM hybrid methodology enables interactive visualization and quantification otherwise not available by conventional methods, such as routine optical microscopes. We hereby demonstrate multiscale applicability of VR-LSFM to (a) interrogate skin fibroblasts interacting with a hyaluronic acid–based hydrogel, (b) navigate through the endocardial trabecular network during zebrafish development, and (c) localize gene therapy-mediated potassium channel expression in adult murine hearts. We further combined our batch intensity normalized segmentation algorithm with deformable image registration to interface a VR environment with imaging computation for the analysis of cardiac contraction. Thus, the VR-LSFM hybrid platform demonstrates an efficient and robust framework for creating a user-directed microenvironment in which we uncovered developmental cardiac mechanics and physiology with high spatiotemporal resolution. PMID:29202458

  2. Detection of occult pericardial hemorrhage early after open-heart surgery using technetium-99m red blood cell radionuclide ventriculography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bateman, T.M.; Czer, L.S.; Gray, R.J.

    1984-11-01

    Pericardial or mediastinal hemorrhage requiring reoperation occurs in 2% to 5% of patients, usually early (0 to 48 hours), after open-heart surgery. This hemorrhage may be occult, and resulting cardiac tamponade may easily be misinterpreted as ventricular dysfunction, common early postoperatively. In such cases, appropriate and timely intervention may not occur. Of 50 patients evaluated by technetium-99m red blood cell gated equilibrium radionuclide ventriculography (RNV) because of early postoperative cardiogenic shock of uncertain etiology, 17 had unique scintigraphic images suggestive of intrathoracic hemorrhage. Of these 17, 5 had a generalized halo of abnormal radioactivity surrounding small hyperdynamic right and leftmore » ventricles, 11 had localized regions of intense blood pool activity outside the cardiac chambers (two with compression of single chambers), and one demonstrated marked radionuclide activity in the right hemithorax (2000 ml of blood at reoperation). Twelve patients had exploratory reoperation for control of hemorrhage as a direct result of the scintigraphic findings, three were successfully treated with fresh frozen plasma and platelet infusions along with medical interventions to optimize cardiac performance, and two patients died in cardiogenic shock (presumed tamponade) without reoperation. In the 12 reoperated patients, all were confirmed to have active pericardial bleeding. Scintigraphic localization of abnormal blood pools within the pericardium corresponded to the sites at which active bleeding was witnessed at reoperation. The abnormal bleeding was etiologically related to the tamponade state, with marked improvement in hemodynamics after reoperation. Nine additional patients were reoperated for presumed tamponade after RNV revealed an exaggerated halo of photon deficiency surrounding the cardiac chambers.« less

  3. Split Bregman multicoil accelerated reconstruction technique: A new framework for rapid reconstruction of cardiac perfusion MRI

    PubMed Central

    Kamesh Iyer, Srikant; Tasdizen, Tolga; Likhite, Devavrat; DiBella, Edward

    2016-01-01

    Purpose: Rapid reconstruction of undersampled multicoil MRI data with iterative constrained reconstruction method is a challenge. The authors sought to develop a new substitution based variable splitting algorithm for faster reconstruction of multicoil cardiac perfusion MRI data. Methods: The new method, split Bregman multicoil accelerated reconstruction technique (SMART), uses a combination of split Bregman based variable splitting and iterative reweighting techniques to achieve fast convergence. Total variation constraints are used along the spatial and temporal dimensions. The method is tested on nine ECG-gated dog perfusion datasets, acquired with a 30-ray golden ratio radial sampling pattern and ten ungated human perfusion datasets, acquired with a 24-ray golden ratio radial sampling pattern. Image quality and reconstruction speed are evaluated and compared to a gradient descent (GD) implementation and to multicoil k-t SLR, a reconstruction technique that uses a combination of sparsity and low rank constraints. Results: Comparisons based on blur metric and visual inspection showed that SMART images had lower blur and better texture as compared to the GD implementation. On average, the GD based images had an ∼18% higher blur metric as compared to SMART images. Reconstruction of dynamic contrast enhanced (DCE) cardiac perfusion images using the SMART method was ∼6 times faster than standard gradient descent methods. k-t SLR and SMART produced images with comparable image quality, though SMART was ∼6.8 times faster than k-t SLR. Conclusions: The SMART method is a promising approach to reconstruct good quality multicoil images from undersampled DCE cardiac perfusion data rapidly. PMID:27036592

  4. Prognostic value of cardiac sympathetic nerve activity evaluated by [123I]m-iodobenzylguanidine imaging in patients with ST-segment elevation myocardial infarction.

    PubMed

    Kasama, Shu; Toyama, Takuji; Sumino, Hiroyuki; Kumakura, Hisao; Takayama, Yoshiaki; Minami, Kazutomo; Ichikawa, Shuichi; Matsumoto, Naoya; Sato, Yuichi; Kurabayashi, Masahiko

    2011-01-01

    Many studies have shown that cardiac sympathetic nerve activity evaluated by [(123)I]m-iodobenzylguanidine ([(123)I]MIBG) scintigraphic study during a stable period is useful for determining the prognosis of patients with chronic heart failure. To examine whether results of this imaging method performed 3 weeks after the onset of ST-segment elevation myocardial infarction (STEMI) are a reliable prognostic marker for patients with STEMI. The study analysed findings for 213 consecutive patients with STEMI undergoing [(123)I]MIBG scintigraphy. The left ventricular (LV) end-diastolic and end-systolic volume and LV ejection fraction (EF) were determined by left ventriculography or echocardiography 3 weeks after the onset of STEMI. The delayed total defect score, heart-to-mediastinum ratio and washout rate (WR) were also determined from [(123)I]MIBG scintigraphy at the same time. Of the 213 patients, 46 experienced major adverse cardiac events (MACE) during the study. The median follow-up period was 982 days. Patients were divided into an event-free group (n = 167; 78.4%) and a MACE group (n = 46; 21.6%). The LV and [(123)I]MIBG scintigraphic parameters in the event-free group were better than those in the MACE group. Multivariate Cox regression analyses revealed that WR was a significant predictor of MACE along with oral nicorandil (ATP-sensitive potassium channel opener) treatment and undergoing percutaneous coronary intervention. On Kaplan-Meier analysis, the event-free rate of patients with a WR<40% was significantly higher than that in patients with a WR ≥ 40% (p<0.001). Even when confined to patients with LVEF>45%, WR was a predictor of MACE, pump failure death, cardiac death and progression of heart failure in patients with STEMI. WR evaluated by [(123)I]MIBG scintigraphy 3 weeks after the onset of STEMI is a significant predictor of MACE in patients with STEMI, independent of LVEF.

  5. [Sudden cardiac death, a major scientific challenge].

    PubMed

    Haissaguerre, Michel; Hocini, Meleze; Sacher, Frédéric; Shah, Ashok

    2010-06-01

    Sudden death is responsible for 350,000 deaths each year in Europe, or 1000 deaths each day, equivalent to the combined mortality from the most lethal cancers (breast, lung and colorectal). Unfortunately, sudden death is widely considered to be "natural", being due to unknown but critical cardiac disorders leading to sudden arrest of cardiac activity. Awareness of its potential preventability is inadequate. Indeed, 80% of cases of sudden death are associated with extremely rapid heartbeats, an "electric tornado" called ventricular fibrillation, caused by ultrarapid firing of ectopic foci or chaotic wave propagation. This arrhythmia strikes like lightning Although it can be associated with myocardial infarction, most victims have structurally normal or slightly altered hearts. The cells which cause this ultrarapid firing originate from the Purkinje system, which constitutes just a fraction (2%) of total cardiac mass. This is borne out by the fact that the risk of fatal arrhythmic events can be reduced by focal thermoablation. What is most important is to identify subjects at risk of such events. It has been suggested that there exists an unidentified subclinical electrical disharmony, which converts into a tornado of ultimately fatal clinical events at a certain threshold level. High-resolution bioelectrical cardiac mapping, functional imaging, and treatment of electrical field disorders are major scientific challenges given their complexity, intraindividual dynamics and interindividual variability.

  6. Value of Formalin Fixation for the Prolonged Preservation of Rodent Myocardial Microanatomical Organization: Evidence by MR Diffusion Tensor Imaging.

    PubMed

    Giannakidis, Archontis; Gullberg, Grant T; Pennell, Dudley J; Firmin, David N

    2016-07-01

    Previous ex vivo diffusion tensor imaging (DTI) studies on formalin-fixed myocardial tissue assumed that, after some initial changes in the first 48 hr since the start of fixation, DTI parameters remain stable over time. Prolonged preservation of cardiac tissue in formalin prior to imaging has been seen many times in the DTI literature as it is considered orderly. Our objective is to define the effects of the prolonged cardiac tissue exposure to formalin on tissue microanatomical organization, as this is assessed by DTI parameters. DTI experiments were conducted on eight excised rodent hearts that were fixed by immersion in formalin. The samples were randomly divided into two equinumerous groups corresponding to shorter (∼2 weeks) and more prolonged (∼6-8 weeks) durations of tissue exposure to formalin prior to imaging. We found that when the duration of cardiac tissue exposure to formalin before imaging increased, water diffusion became less restricted, helix angle (HA) histograms flattened out and exhibited heavier tails (even though the classic HA transmural variation was preserved), and a significant loss of inter-voxel primary diffusion orientation integrity was introduced. The prolonged preservation of cardiac tissue in formalin profoundly affected its microstructural organization, as this was assessed by DTI parameters. The accurate interpretation of diffusivity profiles necessitates awareness of the pitfalls of prolonged cardiac tissue exposure duration to formalin. The acquired knowledge works to the advantage of a proper experimental design of DTI studies of fixed hearts. Anat Rec, 299:878-887, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  7. Implementation of a Computerized Order Entry Tool to Reduce the Inappropriate and Unnecessary Use of Cardiac Stress Tests With Imaging in Hospitalized Patients.

    PubMed

    Gertz, Zachary M; O'Donnell, William; Raina, Amresh; Balderston, Jessica R; Litwack, Andrew J; Goldberg, Lee R

    2016-10-15

    The rising use of imaging cardiac stress tests has led to potentially unnecessary testing. Interventions designed to reduce inappropriate stress testing have focused on the ambulatory setting. We developed a computerized order entry tool intended to reduce the use of imaging cardiac stress tests and improve appropriate use in hospitalized patients. The tool was evaluated using preimplementation and postimplementation cohorts at a single urban academic teaching hospital. All hospitalized patients referred for testing were included. The co-primary outcomes were the use of imaging stress tests as a percentage of all stress tests and the percentage of inappropriate tests, compared between the 2 cohorts. There were 478 patients in the precohort and 463 in the postcohort. The indication was chest pain in 66% and preoperative in 18% and was not significantly different between groups. The use of nonimaging stress tests increased from 4% in the pregroup to 15% in the postgroup (p <0.001). Among very low-risk chest pain patients, the use of nonimaging stress tests increased from 7% to 25% (p <0.001). Inappropriate testing did not change significantly between groups (12% vs 11%). Inappropriate tests were most often preoperative evaluations (83%). In conclusion, our computerized ordering tool significantly increased the use of nonimaging cardiac stress tests and reduced the use of imaging tests yet was not able to reduce inappropriate use. Our study highlights the differences in cardiac stress testing between hospitalized and ambulatory patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Predictors of change in sexual activity after cardiac diagnosis: Elements to inform sexual counseling.

    PubMed

    Mosack, Victoria; Hill, Twyla J; Steinke, Elaine E

    2017-06-01

    Safely returning to sexual activity after being diagnosed with a cardiac condition is at the core of sexual counseling strategies. To further inform sexual counseling, this study examined changes in sexual activity before and after a cardiac diagnosis. Logistic analysis was used to suggest factors that can contribute to a change in sexual activity among cardiac patients. Reduced frequency in sexual activity after a cardiac diagnosis was influenced by greater sexual concerns and a history of smoking, as well as by education and employment status. These findings suggest that cardiac patients experiencing significant concerns about resuming sexual activity need added support through the mental health system.

  9. Radiologic evaluation of acute chest pain--suspected myocardial ischemia.

    PubMed

    Stanford, William

    2007-08-15

    The American College of Radiology has developed appropriateness criteria for a number of clinical conditions and procedures. Criteria are available on imaging tests used in the evaluation of acute chest pain--suspected myocardial ischemia. Imaging tests for a suspected cardiac etiology include transthoracic echocardiography, transesophageal echocardiography, radionuclide perfusion imaging, radionuclide ventriculography, radionuclide infarct avid imaging, and positron emission tomography. If the cardiac ischemic work-up is negative or indeterminate, applicable tests include chest radiography; conventional, multidetector, and electron beam computed tomography; and magnetic resonance imaging. A summary of the criteria, with the advantages and limitations of each test, is presented in this article.

  10. [Assessment of Tricuspid Insufficiency and the Function of Right Ventricle Using Cardiac Magnetic Resonance Imaging Combined with Echocardiography].

    PubMed

    Chen, Hui; Zhao, Yanling; Yu, Jianqun

    2015-08-01

    Right-sided cardiac valvular diseases have traditionally been considered less important than disease of mitral or aortic valve. However, severe tricuspid regurgitation could lead to right ventricle dysfunction and reduce patients' survival rate. In clinic setting, tricuspid valve disease should be paid more attention for patients with secondary tricuspid regurgitation caused by left-sided valvular surgery combined with irreversible annular dilatation increasing the risk of reoperation. In this review, we summarize the epidemiology, anatomy, pathology, diagnosis, ultrasound and cardiac magnetic resonance imaging findings in patients with tricuspid regurgitation.

  11. Impact of enzyme replacement therapy on cardiac morphology and function and late enhancement in Fabry's cardiomyopathy.

    PubMed

    Beer, Meinrad; Weidemann, Frank; Breunig, Frank; Knoll, Anita; Koeppe, Sabrina; Machann, Wolfram; Hahn, Dietbert; Wanner, Christoph; Strotmann, Jörg; Sandstede, Jörn

    2006-05-15

    The present study evaluated the evolution of cardiac morphology, function, and late enhancement as a noninvasive marker of myocardial fibrosis, and their inter-relation during enzyme replacement therapy in patients with Fabry's disease using magnetic resonance imaging and color Doppler myocardial imaging. Late enhancement, which was present in up to 50% of patients, was associated with increased left ventricular mass, the failure of a significant regression of hypertrophy during enzyme replacement therapy, and worse segmental myocardial function. Late enhancement may predict the effect of enzyme replacement therapy on left ventricular mass and cardiac function.

  12. Rigor mortis at the myocardium investigated by post-mortem magnetic resonance imaging.

    PubMed

    Bonzon, Jérôme; Schön, Corinna A; Schwendener, Nicole; Zech, Wolf-Dieter; Kara, Levent; Persson, Anders; Jackowski, Christian

    2015-12-01

    Post-mortem cardiac MR exams present with different contraction appearances of the left ventricle in cardiac short axis images. It was hypothesized that the grade of post-mortem contraction may be related to the post-mortem interval (PMI) or cause of death and a phenomenon caused by internal rigor mortis that may give further insights in the circumstances of death. The cardiac contraction grade was investigated in 71 post-mortem cardiac MR exams (mean age at death 52 y, range 12-89 y; 48 males, 23 females). In cardiac short axis images the left ventricular lumen volume as well as the left ventricular myocardial volume were assessed by manual segmentation. The quotient of both (LVQ) represents the grade of myocardial contraction. LVQ was correlated to the PMI, sex, age, cardiac weight, body mass and height, cause of death and pericardial tamponade when present. In cardiac causes of death a separate correlation was investigated for acute myocardial infarction cases and arrhythmic deaths. LVQ values ranged from 1.99 (maximum dilatation) to 42.91 (maximum contraction) with a mean of 15.13. LVQ decreased slightly with increasing PMI, however without significant correlation. Pericardial tamponade positively correlated with higher LVQ values. Variables such as sex, age, body mass and height, cardiac weight and cause of death did not correlate with LVQ values. There was no difference in LVQ values for myocardial infarction without tamponade and arrhythmic deaths. Based on the observation in our investigated cases, the phenomenon of post-mortem myocardial contraction cannot be explained by the influence of the investigated variables, except for pericardial tamponade cases. Further research addressing post-mortem myocardial contraction has to focus on other, less obvious factors, which may influence the early post-mortem phase too. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  13. Semiautomatic segmentation of the heart from CT images based on intensity and morphological features

    NASA Astrophysics Data System (ADS)

    Redwood, Abena B.; Camp, Jon J.; Robb, Richard A.

    2005-04-01

    The incidence of certain types of cardiac arrhythmias is increasing. Effective, minimally invasive treatment has remained elusive. Pharmacologic treatment has been limited by drug intolerance and recurrence of disease. Catheter based ablation has been moderately successful in treating certain types of cardiac arrhythmias, including typical atrial flutter and fibrillation, but there remains a relatively high rate of recurrence. Additional side effects associated with cardiac ablation procedures include stroke, perivascular lung damage, and skin burns caused by x-ray fluoroscopy. Access to patient specific 3-D cardiac images has potential to significantly improve the process of cardiac ablation by providing the physician with a volume visualization of the heart. This would facilitate more effective guidance of the catheter, increase the accuracy of the ablative process, and eliminate or minimize the damage to surrounding tissue. In this study, a semiautomatic method for faithful cardiac segmentation was investigated using Analyze - a comprehensive processing software package developed at the Biomedical Imaging Resource, Mayo Clinic. This method included use of interactive segmentation based on math morphology and separation of the chambers based on morphological connections. The external surfaces of the hearts were readily segmented, while accurate separation of individual chambers was a challenge. Nonetheless, a skilled operator could manage the task in a few minutes. Useful improvements suggested in this paper would give this method a promising future.

  14. Two-photon induced collagen cross-linking in bioartificial cardiac tissue

    NASA Astrophysics Data System (ADS)

    Kuetemeyer, Kai; Kensah, George; Heidrich, Marko; Meyer, Heiko; Martin, Ulrich; Gruh, Ina; Heisterkamp, Alexander

    2011-08-01

    Cardiac tissue engineering is a promising strategy for regenerative therapies to overcome the shortage of donor organs for transplantation. Besides contractile function, the stiffness of tissue engineered constructs is crucial to generate transplantable tissue surrogates with sufficient mechanical stability to withstand the high pressure present in the heart. Although several collagen cross-linking techniques have proven to be efficient in stabilizing biomaterials, they cannot be applied to cardiac tissue engineering, as cell death occurs in the treated area. Here, we present a novel method using femtosecond (fs) laser pulses to increase the stiffness of collagen-based tissue constructs without impairing cell viability. Raster scanning of the fs laser beam over riboflavin-treated tissue induced collagen cross-linking by two-photon photosensitized singlet oxygen production. One day post-irradiation, stress-strain measurements revealed increased tissue stiffness by around 40% being dependent on the fibroblast content in the tissue. At the same time, cells remained viable and fully functional as demonstrated by fluorescence imaging of cardiomyocyte mitochondrial activity and preservation of active contraction force. Our results indicate that two-photon induced collagen cross-linking has great potential for studying and improving artificially engineered tissue for regenerative therapies.

  15. Quantitative determination of adenovirus-mediated gene delivery to rat cardiac myocytes in vitro and in vivo.

    PubMed Central

    Kass-Eisler, A; Falck-Pedersen, E; Alvira, M; Rivera, J; Buttrick, P M; Wittenberg, B A; Cipriani, L; Leinwand, L A

    1993-01-01

    To optimize the use of modified adenoviruses as vectors for gene delivery to the myocardium, we have characterized infection of cultured fetal and adult rat cardiac myocytes in vitro and of adult cardiac myocytes in vivo by using a replication-defective adenovirus carrying the chloramphenicol acetyltransferase (CAT) reporter gene driven by the cytomegalovirus promoter (AdCMVCATgD). In vitro, virtually all fetal or adult cardiocytes express the CAT gene when infected with 1 plaque-forming unit of virus per cell. CAT enzymatic activity can be detected in these cells as early as 4 hr after infection, reaching near-maximal levels at 48 hr. In fetal cells, CAT expression was maintained without a loss in activity for at least 1 week. Using in vitro studies as a guide, we introduced the AdCMVCATgD virus directly into adult rat myocardium and compared the expression results obtained from virus injection with those obtained by direct injection of pAdCMVCATgD plasmid DNA. The amount of CAT activity resulting from adenovirus infection of the myocardium was orders of magnitude higher than that seen from DNA injection and was proportional to the amount of input virus. Immunostaining for CAT protein in cardiac tissue sections following adenovirus injection demonstrated large numbers of positive cells, reaching nearly 100% of the myocytes in many regions of the heart. Expression of genes introduced by adenovirus peaked at 5 days but was still detectable 55 days following infection. Adenoviruses are therefore a very useful tool for high-efficiency gene transfer into the cardiovascular system. Images Fig. 1 Fig. 5 PMID:8265580

  16. Coronary imaging of anomalous origins and aneurysms of the left coronary artery by multislice computed tomography.

    PubMed

    Castorina, Sergio; Luca, Tonia; Privitera, Giovanna; Riccioli, Vincenzo

    2010-01-01

    In this paper, we describe two cases of anomalous origin of the left coronary artery and two cases of aneurysm on the left coronary artery. Detailed three-dimensional images were acquired by the multislice computed tomography (MSCT) SOMATOM Sensation Cardiac 64 during clinical studies of cardiac diseases. Copyright 2010. Published by Elsevier Inc.

  17. Automatic segmentation of the left ventricle in a cardiac MR short axis image using blind morphological operation

    NASA Astrophysics Data System (ADS)

    Irshad, Mehreen; Muhammad, Nazeer; Sharif, Muhammad; Yasmeen, Mussarat

    2018-04-01

    Conventionally, cardiac MR image analysis is done manually. Automatic examination for analyzing images can replace the monotonous tasks of massive amounts of data to analyze the global and regional functions of the cardiac left ventricle (LV). This task is performed using MR images to calculate the analytic cardiac parameter like end-systolic volume, end-diastolic volume, ejection fraction, and myocardial mass, respectively. These analytic parameters depend upon genuine delineation of epicardial, endocardial, papillary muscle, and trabeculations contours. In this paper, we propose an automatic segmentation method using the sum of absolute differences technique to localize the left ventricle. Blind morphological operations are proposed to segment and detect the LV contours of the epicardium and endocardium, automatically. We test the benchmark Sunny Brook dataset for evaluation of the proposed work. Contours of epicardium and endocardium are compared quantitatively to determine contour's accuracy and observe high matching values. Similarity or overlapping of an automatic examination to the given ground truth analysis by an expert are observed with high accuracy as with an index value of 91.30% . The proposed method for automatic segmentation gives better performance relative to existing techniques in terms of accuracy.

  18. Fully automatic multi-atlas segmentation of CTA for partial volume correction in cardiac SPECT/CT

    NASA Astrophysics Data System (ADS)

    Liu, Qingyi; Mohy-ud-Din, Hassan; Boutagy, Nabil E.; Jiang, Mingyan; Ren, Silin; Stendahl, John C.; Sinusas, Albert J.; Liu, Chi

    2017-05-01

    Anatomical-based partial volume correction (PVC) has been shown to improve image quality and quantitative accuracy in cardiac SPECT/CT. However, this method requires manual segmentation of various organs from contrast-enhanced computed tomography angiography (CTA) data. In order to achieve fully automatic CTA segmentation for clinical translation, we investigated the most common multi-atlas segmentation methods. We also modified the multi-atlas segmentation method by introducing a novel label fusion algorithm for multiple organ segmentation to eliminate overlap and gap voxels. To evaluate our proposed automatic segmentation, eight canine 99mTc-labeled red blood cell SPECT/CT datasets that incorporated PVC were analyzed, using the leave-one-out approach. The Dice similarity coefficient of each organ was computed. Compared to the conventional label fusion method, our proposed label fusion method effectively eliminated gaps and overlaps and improved the CTA segmentation accuracy. The anatomical-based PVC of cardiac SPECT images with automatic multi-atlas segmentation provided consistent image quality and quantitative estimation of intramyocardial blood volume, as compared to those derived using manual segmentation. In conclusion, our proposed automatic multi-atlas segmentation method of CTAs is feasible, practical, and facilitates anatomical-based PVC of cardiac SPECT/CT images.

  19. Functional optical coherence tomography for live dynamic analysis of mouse embryonic cardiogenesis

    NASA Astrophysics Data System (ADS)

    Wang, Shang; Lopez, Andrew L.; Larina, Irina V.

    2018-02-01

    Blood flow, heart contraction, and tissue stiffness are important regulators of cardiac morphogenesis and function during embryonic development. Defining how these factors are integrated is critically important to advance prevention, diagnostics, and treatment of congenital heart defects. Mammalian embryonic development is taking place deep within the female body, which makes cardiodynamic imaging and analysis during early developmental stages in humans inaccessible. With thousands of mutant lines available and well-established genetic manipulation tools, mouse is a great model to understand how biomechanical factors are integrated with molecular pathways to regulate cardiac function and development. Dynamic imaging and quantitative analysis of the biomechanics of live mouse embryos have become increasingly important, which demands continuous advancements in imaging techniques and live assessment approaches. This has been one of the major drives to keep pushing the frontier of embryonic imaging for better resolution, higher speed, deeper penetration, and more diverse and effective contrasts. Optical coherence tomography (OCT) has played a significant role in addressing such demands, and its features in non-labeling imaging, 3D capability, a large working distance, and various functional derivatives allow OCT to cover a number of specific applications in embryonic imaging. Recently, our group has made several technical improvements in using OCT to probe the biomechanical aspects of live developing mouse embryos at early stages. These include the direct volumetric structural and functional imaging of the cardiodynamics, four-dimensional quantitative Doppler imaging and analysis of the cardiac blood flow, and fourdimensional blood flow separation from the cardiac wall tissue in the beating embryonic heart. Here, we present a short review of these studies together with brief descriptions of the previous work that demonstrate OCT as a valuable and useful imaging tool for the research in developmental cardiology.

  20. Paediatric cardiac CT examinations: impact of the iterative reconstruction method ASIR on image quality--preliminary findings.

    PubMed

    Miéville, Frédéric A; Gudinchet, François; Rizzo, Elena; Ou, Phalla; Brunelle, Francis; Bochud, François O; Verdun, Francis R

    2011-09-01

    Radiation dose exposure is of particular concern in children due to the possible harmful effects of ionizing radiation. The adaptive statistical iterative reconstruction (ASIR) method is a promising new technique that reduces image noise and produces better overall image quality compared with routine-dose contrast-enhanced methods. To assess the benefits of ASIR on the diagnostic image quality in paediatric cardiac CT examinations. Four paediatric radiologists based at two major hospitals evaluated ten low-dose paediatric cardiac examinations (80 kVp, CTDI(vol) 4.8-7.9 mGy, DLP 37.1-178.9 mGy·cm). The average age of the cohort studied was 2.6 years (range 1 day to 7 years). Acquisitions were performed on a 64-MDCT scanner. All images were reconstructed at various ASIR percentages (0-100%). For each examination, radiologists scored 19 anatomical structures using the relative visual grading analysis method. To estimate the potential for dose reduction, acquisitions were also performed on a Catphan phantom and a paediatric phantom. The best image quality for all clinical images was obtained with 20% and 40% ASIR (p < 0.001) whereas with ASIR above 50%, image quality significantly decreased (p < 0.001). With 100% ASIR, a strong noise-free appearance of the structures reduced image conspicuity. A potential for dose reduction of about 36% is predicted for a 2- to 3-year-old child when using 40% ASIR rather than the standard filtered back-projection method. Reconstruction including 20% to 40% ASIR slightly improved the conspicuity of various paediatric cardiac structures in newborns and children with respect to conventional reconstruction (filtered back-projection) alone.

  1. In Vivo, High-Frequency Three-Dimensional Cardiac MR Elastography: Feasibility in Normal Volunteers

    PubMed Central

    Arani, Arvin; Glaser, Kevin L.; Arunachalam, Shivaram P.; Rossman, Phillip J.; Lake, David S.; Trzasko, Joshua D.; Manduca, Armando; McGee, Kiaran P.; Ehman, Richard L.; Araoz, Philip A.

    2016-01-01

    Purpose Noninvasive stiffness imaging techniques (elastography) can image myocardial tissue biomechanics in vivo. For cardiac MR elastography (MRE) techniques, the optimal vibration frequency for in vivo experiments is unknown. Furthermore, the accuracy of cardiac MRE has never been evaluated in a geometrically accurate phantom. Therefore, the purpose of this study was to determine the necessary driving frequency to obtain accurate three-dimensional (3D) cardiac MRE stiffness estimates in a geometrically accurate diastolic cardiac phantom and to determine the optimal vibration frequency that can be introduced in healthy volunteers. Methods The 3D cardiac MRE was performed on eight healthy volunteers using 80 Hz, 100 Hz, 140 Hz, 180 Hz, and 220 Hz vibration frequencies. These frequencies were tested in a geometrically accurate diastolic heart phantom and compared with dynamic mechanical analysis (DMA). Results The 3D Cardiac MRE was shown to be feasible in volunteers at frequencies as high as 180 Hz. MRE and DMA agreed within 5% at frequencies greater than 180 Hz in the cardiac phantom. However, octahedral shear strain signal to noise ratios and myocardial coverage was shown to be highest at a frequency of 140 Hz across all subjects. Conclusion This study motivates future evaluation of high-frequency 3D MRE in patient populations. PMID:26778442

  2. Exploration of flexible phenylpropylurea scaffold as novel cardiac myosin activators for the treatment of systolic heart failure.

    PubMed

    Manickam, Manoj; Jalani, Hitesh B; Pillaiyar, Thanigaimalai; Sharma, Niti; Boggu, Pulla Reddy; Venkateswararao, Eeda; Lee, You-Jung; Jeon, Eun-Seok; Jung, Sang-Hun

    2017-07-07

    A series of flexible urea derivatives have been synthesized and demonstrated as selective cardiac myosin ATPase activator. Among them 1-phenethyl-3-(3-phenylpropyl)urea (1, cardiac myosin ATPase activation at 10 μM = 51.1%; FS = 18.90; EF = 12.15) and 1-benzyl-3-(3-phenylpropyl)urea (9, cardiac myosin ATPase activation = 53.3%; FS = 30.04; EF = 18.27) showed significant activity in vitro and in vivo. The change of phenyl ring with tetrahydropyran-4-yl moiety viz., 1-(3-phenylpropyl)-3-((tetrahydro-2H-pyran-4-yl)methyl)urea (14, cardiac myosin ATPase activation = 81.4%; FS = 20.50; EF = 13.10), and morpholine moiety viz., 1-(2-morpholinoethyl)-3-(3-phenylpropyl)urea (21, cardiac myosin ATPase activation = 44.0%; FS = 24.79; EF = 15.65), proved to be efficient to activate the cardiac myosin. The potent compounds 1, 9, 14 and 21 were found to be selective for cardiac myosin over skeletal and smooth myosins. Thus, these urea derivatives are potent scaffold to develop as a newer cardiac myosin activator for the treatment of systolic heart failure. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  3. Computational modeling and analysis for left ventricle motion using CT/Echo image fusion

    NASA Astrophysics Data System (ADS)

    Kim, Ji-Yeon; Kang, Nahyup; Lee, Hyoung-Euk; Kim, James D. K.

    2014-03-01

    In order to diagnose heart disease such as myocardial infarction, 2D strain through the speckle tracking echocardiography (STE) or the tagged MRI is often used. However out-of-plane strain measurement using STE or tagged MRI is inaccurate. Therefore, strain for whole organ which are analyzed by simulation of 3D cardiac model can be applied in clinical diagnosis. To simulate cardiac contraction in a cycle, cardiac physical properties should be reflected in cardiac model. The myocardial wall in left ventricle is represented as a transversely orthotropic hyperelastic material, with the fiber orientation varying sequentially from the epicardial surface, through about 0° at the midwall, to the endocardial surface. A time-varying elastance model is simulated to contract myocardial fiber, and physiological intraventricular systolic pressure curves are employed for the cardiac dynamics simulation in a cycle. And an exact description of the cardiac motion should be acquired in order that essential boundary conditions for cardiac simulation are obtained effectively. Real time cardiac motion can be acquired by using echocardiography and exact cardiac geometrical 3D model can be reconstructed using 3D CT data. In this research, image fusion technology from CT and echocardiography is employed in order to consider patient-specific left ventricle movement. Finally, longitudinal strain from speckle tracking echocardiography which is known to fit actual left ventricle deformation relatively well is used to verify these results.

  4. Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera.

    PubMed

    Ben-Haim, Simona; Kacperski, Krzysztof; Hain, Sharon; Van Gramberg, Dean; Hutton, Brian F; Erlandsson, Kjell; Sharir, Tali; Roth, Nathaniel; Waddington, Wendy A; Berman, Daniel S; Ell, Peter J

    2010-08-01

    We compared simultaneous dual-radionuclide (DR) stress and rest myocardial perfusion imaging (MPI) with a novel solid-state cardiac camera and a conventional SPECT camera with separate stress and rest acquisitions. Of 27 consecutive patients recruited, 24 (64.5+/-11.8 years of age, 16 men) were injected with 74 MBq of (201)Tl (rest) and 250 MBq (99m)Tc-MIBI (stress). Conventional MPI acquisition times for stress and rest are 21 min and 16 min, respectively. Rest (201)Tl for 6 min and simultaneous DR 15-min list mode gated scans were performed on a D-SPECT cardiac scanner. In 11 patients DR D-SPECT was performed first and in 13 patients conventional stress (99m)Tc-MIBI SPECT imaging was performed followed by DR D-SPECT. The DR D-SPECT data were processed using a spill-over and scatter correction method. DR D-SPECT images were compared with rest (201)Tl D-SPECT and with conventional SPECT images by visual analysis employing the 17-segment model and a five-point scale (0 normal, 4 absent) to calculate the summed stress and rest scores. Image quality was assessed on a four-point scale (1 poor, 4 very good) and gut activity was assessed on a four-point scale (0 none, 3 high). Conventional MPI studies were abnormal at stress in 17 patients and at rest in 9 patients. In the 17 abnormal stress studies DR D-SPECT MPI showed 113 abnormal segments and conventional MPI showed 93 abnormal segments. In the nine abnormal rest studies DR D-SPECT showed 45 abnormal segments and conventional MPI showed 48 abnormal segments. The summed stress and rest scores on conventional SPECT and DR D-SPECT were highly correlated (r=0.9790 and 0.9694, respectively). The summed scores of rest (201)Tl D-SPECT and DR-DSPECT were also highly correlated (r=0.9968, p<0.0001 for all). In six patients stress perfusion defects were significantly larger on stress DR D-SPECT images, and five of these patients were imaged earlier by D-SPECT than by conventional SPECT. Fast and high-quality simultaneous DR MPI is feasible with D-SPECT in a single imaging session with comparable diagnostic performance and image quality to conventional SPECT and to a separate rest (201)Tl D-SPECT acquisition.

  5. Hybrid 3D printing: a game-changer in personalized cardiac medicine?

    PubMed

    Kurup, Harikrishnan K N; Samuel, Bennett P; Vettukattil, Joseph J

    2015-12-01

    Three-dimensional (3D) printing in congenital heart disease has the potential to increase procedural efficiency and patient safety by improving interventional and surgical planning and reducing radiation exposure. Cardiac magnetic resonance imaging and computed tomography are usually the source datasets to derive 3D printing. More recently, 3D echocardiography has been demonstrated to derive 3D-printed models. The integration of multiple imaging modalities for hybrid 3D printing has also been shown to create accurate printed heart models, which may prove to be beneficial for interventional cardiologists, cardiothoracic surgeons, and as an educational tool. Further advancements in the integration of different imaging modalities into a single platform for hybrid 3D printing and virtual 3D models will drive the future of personalized cardiac medicine.

  6. Cardiac multidetector computed tomography: basic physics of image acquisition and clinical applications.

    PubMed

    Bardo, Dianna M E; Brown, Paul

    2008-08-01

    Cardiac MDCT is here to stay. And, it is more than just imaging coronary arteries. Understanding the differences in and the benefits of one CT scanner from another will help you to optimize the capabilities of the scanner, but requires a basic understanding of the MDCT imaging physics.This review provides key information needed to understand the differences in the types of MDCT scanners, from 64 - 320 detectors, flat panels, single and dual source configurations, step and shoot prospective and retrospective gating, and how each factor influences radiation dose, spatial and temporal resolution, and image noise.

  7. Validating a new methodology for strain estimation from cardiac cine MRI

    NASA Astrophysics Data System (ADS)

    Elnakib, Ahmed; Beache, Garth M.; Gimel'farb, Georgy; Inanc, Tamer; El-Baz, Ayman

    2013-10-01

    This paper focuses on validating a novel framework for estimating the functional strain from cine cardiac magnetic resonance imaging (CMRI). The framework consists of three processing steps. First, the left ventricle (LV) wall borders are segmented using a level-set based deformable model. Second, the points on the wall borders are tracked during the cardiac cycle based on solving the Laplace equation between the LV edges. Finally, the circumferential and radial strains are estimated at the inner, mid-wall, and outer borders of the LV wall. The proposed framework is validated using synthetic phantoms of the material strains that account for the physiological features and the LV response during the cardiac cycle. Experimental results on simulated phantom images confirm the accuracy and robustness of our method.

  8. Light-sheet fluorescence imaging to localize cardiac lineage and protein distribution

    PubMed Central

    Ding, Yichen; Lee, Juhyun; Ma, Jianguo; Sung, Kevin; Yokota, Tomohiro; Singh, Neha; Dooraghi, Mojdeh; Abiri, Parinaz; Wang, Yibin; Kulkarni, Rajan P.; Nakano, Atsushi; Nguyen, Thao P.; Fei, Peng; Hsiai, Tzung K.

    2017-01-01

    Light-sheet fluorescence microscopy (LSFM) serves to advance developmental research and regenerative medicine. Coupled with the paralleled advances in fluorescence-friendly tissue clearing technique, our cardiac LSFM enables dual-sided illumination to rapidly uncover the architecture of murine hearts over 10 by 10 by 10 mm3 in volume; thereby allowing for localizing progenitor differentiation to the cardiomyocyte lineage and AAV9-mediated expression of exogenous transmembrane potassium channels with high contrast and resolution. Without the steps of stitching image columns, pivoting the light-sheet and sectioning the heart mechanically, we establish a holistic strategy for 3-dimentional reconstruction of the “digital murine heart” to assess aberrant cardiac structures as well as the spatial distribution of the cardiac lineages in neonates and ion-channels in adults. PMID:28165052

  9. Transesophageal echocardiographic strain imaging predicts aortic biomechanics: Beyond diameter.

    PubMed

    Emmott, Alexander; Alzahrani, Haitham; Alreishidan, Mohammed; Therrien, Judith; Leask, Richard L; Lachapelle, Kevin

    2018-03-11

    Clinical guidelines recommend resection of ascending aortic aneurysms at diameters 5.5 cm or greater to prevent rupture or dissection. However, approximately 40% of all ascending aortic dissections occur below this threshold. We propose new transesophageal echocardiography strain-imaging moduli coupled with blood pressure measurements to predict aortic dysfunction below the surgical threshold. A total of 21 patients undergoing aortic resection were recruited to participate in this study. Transesophageal echocardiography imaging of the aortic short-axis and invasive radial blood pressure traces were taken for 3 cardiac cycles. By using EchoPAC (GE Healthcare, Madison, Wis) and postprocessing in MATLAB (MathWorks, Natick, Mass), circumferential stretch profiles were generated and combined with the blood pressure traces. From these data, 2 in vivo stiffness moduli were calculated: the Cardiac Cycle Pressure Modulus and Cardiac Cycle Stress Modulus. From the resected aortic ring, testing squares were isolated for ex vivo mechanical analysis and histopathology. Each square underwent equibiaxial tensile testing to generate stress-stretch profiles for each patient. Two ex vivo indices were calculated from these profiles (energy loss and incremental stiffness) for comparison with the Cardiac Cycle Pressure Modulus and Cardiac Cycle Stress Modulus. The echo-derived stiffness moduli demonstrate positive significant covariance with ex vivo tensile biomechanical indices: energy loss (vs Cardiac Cycle Pressure Modulus: R 2  = 0.5873, P < .0001; vs Cardiac Cycle Stress Modulus: R 2  = 0.6401, P < .0001) and apparent stiffness (vs Cardiac Cycle Pressure Modulus: R 2  = 0.2079, P = .0378; vs Cardiac Cycle Stress Modulus: R 2  = 0.3575, P = .0042). Likewise, these transesophageal echocardiography-derived moduli are highly predictive of the histopathologic composition of collagen and elastin (collagen/elastin ratio vs Cardiac Cycle Pressure Modulus: R 2  = 0.6165, P < .0001; vs Cardiac Cycle Stress Modulus: R 2  = 0.6037, P < .0001). Transesophageal echocardiography-derived stiffness moduli correlate strongly with aortic wall biomechanics and histopathology, which demonstrates the added benefit of using simple echocardiography-derived biomechanics to stratify patient populations. Copyright © 2018. Published by Elsevier Inc.

  10. Ultrasound and Cadaveric Prosections as Methods for Teaching Cardiac Anatomy: A Comparative Study

    ERIC Educational Resources Information Center

    Griksaitis, Michael J.; Sawdon, Marina A.; Finn, Gabrielle M.

    2012-01-01

    This study compared the efficacy of two cardiac anatomy teaching modalities, ultrasound imaging and cadaveric prosections, for learning cardiac gross anatomy. One hundred and eight first-year medical students participated. Two weeks prior to the teaching intervention, students completed a pretest to assess their prior knowledge and to ensure that…

  11. Virtual Humans for Implantable Device Safety Assessment in MRI: Mitigating Magnetic Resonance Imaging Hazards for Implanted Medical Devices.

    PubMed

    Brown, James E; Qiang, Rui; Stadnik, Paul J; Stotts, Larry J; Von Arx, Jeffrey A

    2017-01-01

    Magnetic resonance imaging (MRI) is the preferred modality for soft tissue imaging because of its nonionizing radiation and lack of contrast agent. Due to interactions between the MR system and active implantable medical devices (AIMDs), patients with implants such as pacemakers are generally denied access to MRI, which presents a detriment to that population. It has been estimated that 50-75% of patients with a cardiac device were denied access to MRI scanning and, moreover, that 17% of pacemaker patients need an MRI within 12 months of implantation [1]. In recent years, AIMD manufacturers, such as Biotronik, have assessed the conditional safety of devices in MRI.

  12. (99m)Tc-pyrophosphate scintigraphy for differentiating light-chain cardiac amyloidosis from the transthyretin-related familial and senile cardiac amyloidoses.

    PubMed

    Bokhari, Sabahat; Castaño, Adam; Pozniakoff, Ted; Deslisle, Susan; Latif, Farhana; Maurer, Mathew S

    2013-03-01

    Differentiating immunoglobulin light-chain (AL) from transthyretin-related cardiac amyloidoses (ATTR) is imperative given implications for prognosis, therapy, and genetic counseling. We validated the discriminatory ability of (99m)Tc-pyrophosphate ((99m)Tc-PYP) scintigraphy in AL versus ATTR. Forty-five subjects (12 AL, 16 ATTR wild type, and 17 ATTR mutants) underwent (99m)Tc-PYP planar and single-photon positive emission computed tomography cardiac imaging. Scans were performed by experienced nuclear cardiologists blinded to the subjects' cohort assignment. Cardiac retention was assessed with both a semiquantitative visual score (range, 0; no uptake to 3, diffuse uptake) and by quantitative analysis by drawing a region of interest over the heart corrected for contralateral counts and calculating a heart-to-contralateral ratio. Subjects with ATTR cardiac amyloid had a significantly higher semiquantitative cardiac visual score than the AL cohort (2.9±0.06 versus 0.8±0.27; P<0.0001) as well as a higher quantitative score (1.80±0.04 versus 1.21±0.04; P<0.0001). Using a heart-to-contralateral ratio >1.5 consistent with intensely diffuse myocardial tracer retention had a 97% sensitivity and 100% specificity with area under the curve 0.992, P<0.0001 for identifying ATTR cardiac amyloidosis. (99m)Tc-PYP cardiac imaging distinguishes AL from ATTR cardiac amyloidosis and may be a simple, widely available method for identifying subjects with ATTR cardiac amyloidosis, which should be studied in a larger prospective manner.

  13. Improved virtual cardiac phantom with variable diastolic filling rates and coronary artery velocities

    NASA Astrophysics Data System (ADS)

    Sturgeon, Gregory M.; Richards, Taylor W.; Samei, E.; Segars, W. P.

    2017-03-01

    To facilitate studies of measurement uncertainty in computed tomography angiography (CTA), we investigated the cardiac motion profile and resulting coronary artery motion utilizing innovative dynamic virtual and physical phantoms. The four-chamber cardiac finite element (FE) model developed in the Living Heart Project (LHP) served as the computational basis for our virtual cardiac phantom. This model provides deformation or strain information at high temporal and spatial resolution, exceeding that of speckle tracking echocardiography or tagged MRI. This model was extended by fitting its motion profile to left ventricular (LV) volume-time curves obtained from patient echocardiography data. By combining the dynamic patient variability from echo with the local strain information from the FE model, a series of virtual 4D cardiac phantoms were developed. Using the computational phantoms, we characterized the coronary motion and its effect on plaque imaging under a range of heart rates subject to variable diastolic function. The coronary artery motion was sampled at 248 spatial locations over 500 consecutive time frames. The coronary artery velocities were calculated as their average velocity during an acquisition window centered at each time frame, which minimized the discretization error. For the initial set of twelve patients, the diastatic coronary artery velocity ranged from 36.5 mm/s to 2.0 mm/s with a mean of 21.4 mm/s assuming an acquisition time of 75 ms. The developed phantoms have great potential in modeling cardiac imaging, providing a known truth and multiple realistic cardiac motion profiles to evaluate different image acquisition or reconstruction methods.

  14. Imaging of cardiac perfusion of free-breathing small animals using dynamic phase-correlated micro-CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sawall, Stefan; Kuntz, Jan; Socher, Michaela

    Purpose:Mouse models of cardiac diseases have proven to be a valuable tool in preclinical research. The high cardiac and respiratory rates of free breathing mice prohibit conventional in vivo cardiac perfusion studies using computed tomography even if gating methods are applied. This makes a sacrification of the animals unavoidable and only allows for the application of ex vivo methods. Methods: To overcome this issue the authors propose a low dose scan protocol and an associated reconstruction algorithm that allows for in vivo imaging of cardiac perfusion and associated processes that are retrospectively synchronized to the respiratory and cardiac motion ofmore » the animal. The scan protocol consists of repetitive injections of contrast media within several consecutive scans while the ECG, respiratory motion, and timestamp of contrast injection are recorded and synchronized to the acquired projections. The iterative reconstruction algorithm employs a six-dimensional edge-preserving filter to provide low-noise, motion artifact-free images of the animal examined using the authors' low dose scan protocol. Results: The reconstructions obtained show that the complete temporal bolus evolution can be visualized and quantified in any desired combination of cardiac and respiratory phase including reperfusion phases. The proposed reconstruction method thereby keeps the administered radiation dose at a minimum and thus reduces metabolic inference to the animal allowing for longitudinal studies. Conclusions: The authors' low dose scan protocol and phase-correlated dynamic reconstruction algorithm allow for an easy and effective way to visualize phase-correlated perfusion processes in routine laboratory studies using free-breathing mice.« less

  15. CT cardiac imaging: evolution from 2D to 3D backprojection

    NASA Astrophysics Data System (ADS)

    Tang, Xiangyang; Pan, Tinsu; Sasaki, Kosuke

    2004-04-01

    The state-of-the-art multiple detector-row CT, which usually employs fan beam reconstruction algorithms by approximating a cone beam geometry into a fan beam geometry, has been well recognized as an important modality for cardiac imaging. At present, the multiple detector-row CT is evolving into volumetric CT, in which cone beam reconstruction algorithms are needed to combat cone beam artifacts caused by large cone angle. An ECG-gated cardiac cone beam reconstruction algorithm based upon the so-called semi-CB geometry is implemented in this study. To get the highest temporal resolution, only the projection data corresponding to 180° plus the cone angle are row-wise rebinned into the semi-CB geometry for three-dimensional reconstruction. Data extrapolation is utilized to extend the z-coverage of the ECG-gated cardiac cone beam reconstruction algorithm approaching the edge of a CT detector. A helical body phantom is used to evaluate the ECG-gated cone beam reconstruction algorithm"s z-coverage and capability of suppressing cone beam artifacts. Furthermore, two sets of cardiac data scanned by a multiple detector-row CT scanner at 16 x 1.25 (mm) and normalized pitch 0.275 and 0.3 respectively are used to evaluate the ECG-gated CB reconstruction algorithm"s imaging performance. As a reference, the images reconstructed by a fan beam reconstruction algorithm for multiple detector-row CT are also presented. The qualitative evaluation shows that, the ECG-gated cone beam reconstruction algorithm outperforms its fan beam counterpart from the perspective of cone beam artifact suppression and z-coverage while the temporal resolution is well maintained. Consequently, the scan speed can be increased to reduce the contrast agent amount and injection time, improve the patient comfort and x-ray dose efficiency. Based up on the comparison, it is believed that, with the transition of multiple detector-row CT into volumetric CT, ECG-gated cone beam reconstruction algorithms will provide better image quality for CT cardiac applications.

  16. Phantom evaluation of a cardiac SPECT/VCT system that uses a common set of solid-state detectors for both emission and transmission scans.

    PubMed

    Bai, Chuanyong; Conwell, Richard; Kindem, Joel; Babla, Hetal; Gurley, Mike; De Los Santos, Romer; Old, Rex; Weatherhead, Randy; Arram, Samia; Maddahi, Jamshid

    2010-06-01

    We developed a cardiac SPECT system (X-ACT) with low dose volume CT transmission-based attenuation correction (AC). Three solid-state detectors are configured to form a triple-head system for emission scans and reconfigured to form a 69-cm field-of-view detector arc for transmission scans. A near mono-energetic transmission line source is produced from the collimated fluorescence x-ray emitted from a lead target when the target is illuminated by a narrow polychromatic x-ray beam from an x-ray tube. Transmission scans can be completed in 1 min with insignificant patient dose (deep dose equivalent <5 muSv). We used phantom studies to evaluate (1) the accuracy of the reconstructed attenuation maps, (2) the effect of AC on image uniformity, and (3) the effect of AC on defect contrast (DC). The phantoms we used included an ACR phantom, an anthropomorphic phantom with a uniform cardiac insert, and an anthropomorphic phantom with two defects in the cardiac insert. The reconstructed attenuation coefficient of water at 140 keV was .150 +/- .003/cm in the uniform region of the ACR phantom, .151 +/- .003/cm and .151 +/- .002/cm in the liver and cardiac regions of the anthropomorphic phantom. The ACR phantom images with AC showed correction of the bowing effect due to attenuation in the images without AC (NC). The 17-segment scores of the images of the uniform cardiac insert were 78.3 +/- 6.5 before and 87.9 +/- 3.3 after AC (average +/- standard deviation). The inferior-to-anterior wall ratio and the septal-to-lateral wall ratio were .99 and 1.16 before and 1.02 and 1.00 after AC. The DC of the two defects was .528 and .156 before and .628 and .173 after AC. The X-ACT system generated accurate attenuation maps with 1-minute transmission scans. AC improved image quality and uniformity over NC.

  17. Long-Term Outcomes of Catheter Ablation of Ventricular Tachycardia in Patients With Cardiac Sarcoidosis.

    PubMed

    Muser, Daniele; Santangeli, Pasquale; Pathak, Rajeev K; Castro, Simon A; Liang, Jackson J; Magnani, Silvia; Hayashi, Tatsuya; Garcia, Fermin C; Hutchinson, Mathew D; Supple, Gregory E; Frankel, David S; Riley, Michael P; Lin, David; Schaller, Robert D; Desjardins, Benoit; Dixit, Sanjay; Callans, David J; Zado, Erica S; Marchlinski, Francis E

    2016-08-01

    Catheter ablation (CA) of ventricular tachycardia (VT) in patients with cardiac sarcoidosis can be challenging because of the complex underlying substrate. We sought to determine the long-term outcome of CA of VT in patients with cardiac sarcoidosis. We enrolled 31 patients (age, 55±10 years) with diagnosis of cardiac sarcoidosis based on Heart Rhythm Society criteria and VT who underwent CA. In 23 (74%) patients, preprocedure cardiac magnetic resonance imaging and positron emission tomographic (PET) evaluation were performed. Preprocedure magnetic resonance imaging was positive for late gadolinium enhancement in 21 of 23 (91%) patients, whereas abnormal 18-fluorodeoxyglucose uptake was found in 15 of 23 (65%) cases. In 14 of 15 patients with positive PET at baseline, PET was repeated after 6.1±3.7-month follow-up. After a median follow-up of 2.5 (range, 0-10.5) years, 1 (3%) patient died and 4 (13%) underwent heart transplant. Overall VT-free survival was 55% at 2-year follow-up. Among the 16 (52%) patients with VT recurrences, CA resulted in a significant reduction of VT burden, with 8 (50%) having only isolated (1-3) VT episodes and only 1 patient with recurrent VT storm. The presence of late gadolinium enhancement at magnetic resonance imaging, a positive PET at baseline, and lack of PET improvement over follow-up were associated with increased risk of recurrent VT. In patients with cardiac sarcoidosis and VT, CA is effective in achieving long-term freedom from VT or improvement in VT burden in the majority of patients. The presence of late gadolinium enhancement at magnetic resonance imaging, a positive PET scan at baseline, or lack of improvement at repeat PET over follow-up predict worse arrhythmia-free survival. © 2016 American Heart Association, Inc.

  18. Multi-Physics MRI-Based Two-Layer Fluid-Structure Interaction Anisotropic Models of Human Right and Left Ventricles with Different Patch Materials: Cardiac Function Assessment and Mechanical Stress Analysis

    PubMed Central

    Tang, Dalin; Yang, Chun; Geva, Tal; Gaudette, Glenn; del Nido, Pedro J.

    2011-01-01

    Multi-physics right and left ventricle (RV/LV) fluid-structure interaction (FSI) models were introduced to perform mechanical stress analysis and evaluate the effect of patch materials on RV function. The FSI models included three different patch materials (Dacron scaffold, treated pericardium, and contracting myocardium), two-layer construction, fiber orientation, and active anisotropic material properties. The models were constructed based on cardiac magnetic resonance (CMR) images acquired from a patient with severe RV dilatation and solved by ADINA. Our results indicate that the patch model with contracting myocardium leads to decreased stress level in the patch area, improved RV function and patch area contractility. PMID:21765559

  19. Automatic Parameterization Strategy for Cardiac Electrophysiology Simulations

    PubMed Central

    Costa, Caroline Mendonca; Hoetzl, Elena; Rocha, Bernardo Martins; Prassl, Anton J; Plank, Gernot

    2014-01-01

    Driven by recent advances in medical imaging, image segmentation and numerical techniques, computer models of ventricular electrophysiology account for increasingly finer levels of anatomical and biophysical detail. However, considering the large number of model parameters involved parameterization poses a major challenge. A minimum requirement in combined experimental and modeling studies is to achieve good agreement in activation and repolarization sequences between model and experiment or patient data. In this study, we propose basic techniques which aid in determining bidomain parameters to match activation sequences. An iterative parameterization algorithm is implemented which determines appropriate bulk conductivities which yield prescribed velocities. In addition, a method is proposed for splitting the computed bulk conductivities into individual bidomain conductivities by prescribing anisotropy ratios. PMID:24729986

  20. Multimodality Molecular Imaging of Cardiac Cell Transplantation: Part I. Reporter Gene Design, Characterization, and Optical in Vivo Imaging of Bone Marrow Stromal Cells after Myocardial Infarction

    PubMed Central

    Parashurama, Natesh; Ahn, Byeong-Cheol; Ziv, Keren; Ito, Ken; Paulmurugan, Ramasamy; Willmann, Jürgen K.; Chung, Jaehoon; Ikeno, Fumiaki; Swanson, Julia C.; Merk, Denis R.; Lyons, Jennifer K.; Yerushalmi, David; Teramoto, Tomohiko; Kosuge, Hisanori; Dao, Catherine N.; Ray, Pritha; Patel, Manishkumar; Chang, Ya-fang; Mahmoudi, Morteza; Cohen, Jeff Eric; Goldstone, Andrew Brooks; Habte, Frezghi; Bhaumik, Srabani; Yaghoubi, Shahriar; Robbins, Robert C.; Dash, Rajesh; Yang, Phillip C.; Brinton, Todd J.; Yock, Paul G.; McConnell, Michael V.

    2016-01-01

    Purpose To use multimodality reporter-gene imaging to assess the serial survival of marrow stromal cells (MSC) after therapy for myocardial infarction (MI) and to determine if the requisite preclinical imaging end point was met prior to a follow-up large-animal MSC imaging study. Materials and Methods Animal studies were approved by the Institutional Administrative Panel on Laboratory Animal Care. Mice (n = 19) that had experienced MI were injected with bone marrow–derived MSC that expressed a multimodality triple fusion (TF) reporter gene. The TF reporter gene (fluc2-egfp-sr39ttk) consisted of a human promoter, ubiquitin, driving firefly luciferase 2 (fluc2), enhanced green fluorescent protein (egfp), and the sr39tk positron emission tomography reporter gene. Serial bioluminescence imaging of MSC-TF and ex vivo luciferase assays were performed. Correlations were analyzed with the Pearson product-moment correlation, and serial imaging results were analyzed with a mixed-effects regression model. Results Analysis of the MSC-TF after cardiac cell therapy showed significantly lower signal on days 8 and 14 than on day 2 (P = .011 and P = .001, respectively). MSC-TF with MI demonstrated significantly higher signal than MSC-TF without MI at days 4, 8, and 14 (P = .016). Ex vivo luciferase activity assay confirmed the presence of MSC-TF on days 8 and 14 after MI. Conclusion Multimodality reporter-gene imaging was successfully used to assess serial MSC survival after therapy for MI, and it was determined that the requisite preclinical imaging end point, 14 days of MSC survival, was met prior to a follow-up large-animal MSC study. © RSNA, 2016 Online supplemental material is available for this article. PMID:27308957

  1. Non-Cartesian Balanced SSFP Pulse Sequences for Real-Time Cardiac MRI

    PubMed Central

    Feng, Xue; Salerno, Michael; Kramer, Christopher M.; Meyer, Craig H.

    2015-01-01

    Purpose To develop a new spiral-in/out balanced steady-state free precession (bSSFP) pulse sequence for real-time cardiac MRI and compare it with radial and spiral-out techniques. Methods Non-Cartesian sampling strategies are efficient and robust to motion and thus have important advantages for real-time bSSFP cine imaging. This study describes a new symmetric spiral-in/out sequence with intrinsic gradient moment compensation and SSFP refocusing at TE=TR/2. In-vivo real-time cardiac imaging studies were performed to compare radial, spiral-out, and spiral-in/out bSSFP pulse sequences. Furthermore, phase-based fat-water separation taking advantage of the refocusing mechanism of the spiral-in/out bSSFP sequence was also studied. Results The image quality of the spiral-out and spiral-in/out bSSFP sequences was improved with off-resonance and k-space trajectory correction. The spiral-in/out bSSFP sequence had the highest SNR, CNR, and image quality ratings, with spiral-out bSSFP sequence second in each category and the radial bSSFP sequence third. The spiral-in/out bSSFP sequence provides separated fat and water images with no additional scan time. Conclusions In this work a new spiral-in/out bSSFP sequence was developed and tested. The superiority of spiral bSSFP sequences over the radial bSSFP sequence in terms of SNR and reduced artifacts was demonstrated in real-time MRI of cardiac function without image acceleration. PMID:25960254

  2. Effect of respiratory and cardiac gating on the major diffusion-imaging metrics.

    PubMed

    Hamaguchi, Hiroyuki; Tha, Khin Khin; Sugimori, Hiroyuki; Nakanishi, Mitsuhiro; Nakagawa, Shin; Fujiwara, Taro; Yoshida, Hirokazu; Takamori, Sayaka; Shirato, Hiroki

    2016-08-01

    The effect of respiratory gating on the major diffusion-imaging metrics and that of cardiac gating on mean kurtosis (MK) are not known. For evaluation of whether the major diffusion-imaging metrics-MK, fractional anisotropy (FA), and mean diffusivity (MD) of the brain-varied between gated and non-gated acquisitions, respiratory-gated, cardiac-gated, and non-gated diffusion-imaging of the brain were performed in 10 healthy volunteers. MK, FA, and MD maps were constructed for all acquisitions, and the histograms were constructed. The normalized peak height and location of the histograms were compared among the acquisitions by use of Friedman and post hoc Wilcoxon tests. The effect of the repetition time (TR) on the diffusion-imaging metrics was also tested, and we corrected for its variation among acquisitions, if necessary. The results showed a shift in the peak location of the MK and MD histograms to the right with an increase in TR (p ≤ 0.01). The corrected peak location of the MK histograms, the normalized peak height of the FA histograms, the normalized peak height and the corrected peak location of the MD histograms varied significantly between the gated and non-gated acquisitions (p < 0.05). These results imply an influence of respiration and cardiac pulsation on the major diffusion-imaging metrics. The gating conditions must be kept identical if reproducible results are to be achieved. © The Author(s) 2016.

  3. Novel Three-Dimensional Image Fusion Software to Facilitate Guidance of Complex Cardiac Catheterization : 3D image fusion for interventions in CHD.

    PubMed

    Goreczny, Sebastian; Dryzek, Pawel; Morgan, Gareth J; Lukaszewski, Maciej; Moll, Jadwiga A; Moszura, Tomasz

    2017-08-01

    We report initial experience with novel three-dimensional (3D) image fusion software for guidance of transcatheter interventions in congenital heart disease. Developments in fusion imaging have facilitated the integration of 3D roadmaps from computed tomography or magnetic resonance imaging datasets. The latest software allows live fusion of two-dimensional (2D) fluoroscopy with pre-registered 3D roadmaps. We reviewed all cardiac catheterizations guided with this software (Philips VesselNavigator). Pre-catheterization imaging and catheterization data were collected focusing on fusion of 3D roadmap, intervention guidance, contrast and radiation exposure. From 09/2015 until 06/2016, VesselNavigator was applied in 34 patients for guidance (n = 28) or planning (n = 6) of cardiac catheterization. In all 28 patients successful 2D-3D registration was performed. Bony structures combined with the cardiovascular silhouette were used for fusion in 26 patients (93%), calcifications in 9 (32%), previously implanted devices in 8 (29%) and low-volume contrast injection in 7 patients (25%). Accurate initial 3D roadmap alignment was achieved in 25 patients (89%). Six patients (22%) required realignment during the procedure due to distortion of the anatomy after introduction of stiff equipment. Overall, VesselNavigator was applied successfully in 27 patients (96%) without any complications related to 3D image overlay. VesselNavigator was useful in guidance of nearly all of cardiac catheterizations. The combination of anatomical markers and low-volume contrast injections allowed reliable 2D-3D registration in the vast majority of patients.

  4. Physician Decision-Making And Trends In Use Of Cardiac Stress Testing To Diagnose Coronary Heart Disease In The United States, 1993–2010

    PubMed Central

    Ladapo, Joseph A.; Blecker, Saul; Douglas, Pamela S.

    2014-01-01

    Background Cardiac stress testing, particularly with imaging, has been the focus of debates about rising health care costs, inappropriate use, and patient safety in the context of radiation exposure. Objective To determine whether U.S. trends in cardiac stress test use may be attributable to population shifts in demographics, risk factors, and provider characteristics and evaluate whether racial/ethnic disparities exist in physician decision making. Design Analyses of repeated cross-sectional data. Setting National Ambulatory Medical Care Survey and National Hospital Ambulatory Medical Care Survey (1993 to 2010). Patients Adults without coronary heart disease. Measurements Cardiac stress test referrals and inappropriate use. Results Between 1993 to 1995 and 2008 to 2010, the annual number of U.S. ambulatory visits in which a cardiac stress test was ordered or performed increased from 28 per 10 000 visits to 45 per 10 000 visits. No trend was found toward more frequent testing after adjustment for patient characteristics, risk factors, and provider characteristics (P = 0.134). Cardiac stress tests with imaging comprised a growing portion of all tests, increasing from 59% in 1993 to 1995 to 87% in 2008 to 2010. At least 34.6% were probably inappropriate, with associated annual costs and harms of $501 million and 491 future cases of cancer. Authors found no evidence of a lower likelihood of black patients receiving a cardiac stress test (odds ratio, 0.91 [95% CI, 0.69 to 1.21]) than white patients, although some evidence of disparity in Hispanic patients was found (odds ratio, 0.75 [CI, 0.55 to 1.02]). Limitations Cross-sectional design with limited clinical data. Conclusion National growth in cardiac stress test use can largely be explained by population and provider characteristics, but use of imaging cannot. Physician decision making about cardiac stress test use does not seem to contribute to racial/ethnic disparities in cardiovascular disease. PMID:25285541

  5. Pyridostigmine protects against cardiomyopathy associated with adipose tissue browning and improvement of vagal activity in high-fat diet rats.

    PubMed

    Lu, Yi; Wu, Qing; Liu, Long-Zhu; Yu, Xiao-Jiang; Liu, Jin-Jun; Li, Man-Xiang; Zang, Wei-Jin

    2018-04-01

    Obesity, a major contributor to the development of cardiovascular diseases, is associated with an autonomic imbalance characterized by sympathetic hyperactivity and diminished vagal activity. Vagal activation plays important roles in weight loss and improvement of cardiac function. Pyridostigmine is a reversible acetylcholinesterase inhibitor, but whether it ameliorates cardiac lipid accumulation and cardiac remodeling in rats fed a high-fat diet has not been determined. This study investigated the effects of pyridostigmine on high-fat diet-induced cardiac dysfunction and explored the potential mechanisms. Rats were fed a normal or high-fat diet and treated with pyridostigmine. Vagal discharge was evaluated using the BL-420S system, and cardiac function by echocardiograms. Lipid deposition and cardiac remodeling were determined histologically. Lipid utility was assessed by qPCR. A high-fat diet led to a significant reduction in vagal discharge and lipid utility and a marked increase in lipid accumulation, cardiac remodeling, and cardiac dysfunction. Pyridostigmine improved vagal activity and lipid metabolism disorder and cardiac remodeling, accompanied by an improvement of cardiac function in high-fat diet-fed rats. An increase in the browning of white adipose tissue in pyridostigmine-treated rats was also observed and linked to the expression of UCP-1 and CIDEA. Additionally, pyridostigmine facilitated activation of brown adipose tissue via activation of the SIRT-1/AMPK/PGC-1α pathway. In conclusion, a high-fat diet resulted in cardiac lipid accumulation, cardiac remodeling, and a significant decrease in vagal discharge. Pyridostigmine ameliorated cardiomyopathy, an effect related to reduced cardiac lipid accumulation, and facilitated the browning of white adipose tissue while activating brown adipose tissue. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Vitamin D treatment attenuates cardiac FGF23/FGFR4 signaling and hypertrophy in uremic rats.

    PubMed

    Leifheit-Nestler, Maren; Grabner, Alexander; Hermann, Laura; Richter, Beatrice; Schmitz, Karin; Fischer, Dagmar-Christiane; Yanucil, Christopher; Faul, Christian; Haffner, Dieter

    2017-09-01

    Vitamin D deficiency and excess of circulating fibroblast growth factor 23 (FGF23) contribute to cardiovascular mortality in patients with chronic kidney disease (CKD). FGF23 activates FGF receptor 4 and (FGFR4) calcineurin/nuclear factor of activated T cells (NFAT) signaling in cardiac myocytes, thereby causing left ventricular hypertrophy (LVH). Here, we determined if 1,25-dihydroxyvitamin D (calcitriol) inhibits FGF23-induced cardiac signaling and LVH. 5/6 nephrectomized (5/6 Nx) rats were treated with different doses of calcitriol for 4 or 10 weeks and cardiac expression of FGF23/FGFR4 and activation of calcineurin/NFAT as well as LVH were analyzed. FGFR4 activation and hypertrophic cell growth were studied in cultured cardiac myocytes that were co-treated with FGF23 and calcitriol. In 5/6Nx rats with LVH, we detected elevated FGF23 expression in bone and myocardium, increased cardiac expression of FGFR4 and elevated cardiac activation of calcineurin/NFAT signaling. Cardiac expression levels of FGF23 and FGFR4 significantly correlated with the presence of LVH in uremic rats. Treatment with calcitriol reduced LVH as well as cardiac FGFR4 expression and calcineurin/NFAT activation. Bone and cardiac FGF23 expression were further stimulated by calcitriol in a dose-dependent manner, but levels of intact cardiac FGF23 protein were suppressed by high-dose calcitriol. In cultured cardiac myocytes, co-treatment with calcitriol blocked FGF23-induced activation of FGFR4 and hypertrophic cell growth. Our data suggest that in CKD, cardioprotective effects of calcitriol stem from its inhibitory actions on the cardiac FGF23/FGFR4 system, and based on their counterbalancing effects on cardiac myocytes, high FGF23 and low calcitriol synergistically contribute to cardiac hypertrophy. © The Author 2017. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  7. Hydatid cyst of the interventricular septum and contribution of magnetic resonance imaging.

    PubMed

    Kulan, K; Tuncer, C; Kulan, C; Serce, K; Goldeli, O; Irhan, S; Komsuoglu, B

    1995-01-01

    Cardiac echinococcosis has not been reported frequently. Because of the risk of potentially lethal complications, early diagnosis and definitive treatment are very important. We report a case of a cardiac echinococcal cyst in the interventricular septum. The cyst that caused angina and showed ischemic changes in electrocardiogram was diagnosed by two-dimensional echocardiography and magnetic resonance imaging and was treated surgically.

  8. Induced apnea enhances image quality and visualization of cardiopulmonary anatomic during contrastenhanced cardiac computerized tomographic angiography in children

    PubMed Central

    Chakravarthy, Murali; Sunilkumar, Gubbihalli; Pargaonkar, Sumant; Hosur, Rajathadri; Harivelam, Chidananda; Kavaraganahalli, Deepak; Srinivasan, Pradeep

    2015-01-01

    Objective: The purpose of our study was to determine the effect of induced apnea on quality of cardiopulmonary structures during computerized tomographic (CT) angiography images in children with congenital heart diseases. Methods: Pediatric patients with congenital heart defects undergoing cardiac CT angiography at our facility in the past 3 years participated in this study. The earlier patients underwent cardiac CT angiography without induced apnea and while, later, apnea was induced in patients, which was followed by electrocardiogram gated cardiac CT angiography. General anesthesia was induced using sleep dose of intravenous propofol. After the initial check CT, on request by the radiologist, apnea was induced by the anesthesiologist by administering 1 mg/kg of intravenous suxamethonium. Soon after apnea ensued, the contrast was injected, and CT angiogram carried out. CT images in the “apnea group” were compared with those in “nonapnea group.” After the completion of the procedure, the patients were mask ventilated with 100% oxygen till the spontaneous ventilation was restored. Results: We studied 46 patients, of whom 36 with apnea and yet another 10 without. The quality of the image, visualization of structures such as cardiac wall, outflow tracts, lung field, aortopulmonary shunts, and coronary arteries were analyzed and subjected to statistical analysis (Mann–Whitney U, Fischer's exact test and Pearson's Chi-square test). In the induced apnea group, overall image quality was considered excellent in 89% (n = 33) of the studies, while in the “no apnea group,” only 30% of studies were excellent. Absent or minimal motion artifacts were seen in a majority of the studies in apnea group (94%). In the nonapnea group, the respiratory and body motion artifacts were severe in 50%, moderate in 30%, and minimal in 20%, but they were significantly lesser in the apnea group. All the studied parameters were statistically significant in the apnea group in contrast to nonapnea group (P < 0.000). Conclusion: The image quality of cardiac CT angiography greatly improves, and motion artifact significantly decreases with the use of induced apnea in pediatrics patients being evaluated for congenital heart disease. This technique poses no additional morbidity of significance. PMID:25849686

  9. Integrated RFA/OCT catheter for real-time guidance of cardiac RFA therapy (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Fu, Xiaoyong; Blumenthal, Colin; Dosluoglu, Deniz; Wang, Yves T.; Jenkins, Michael W.; Souza, Rakesh; Snyder, Christopher; Arruda, Mauricio; Rollins, Andrew M.

    2016-03-01

    Currently, cardiac radiofrequency ablation is guided by indirect signals. We demonstrate an integrated radiofrequency ablation (RFA) and optical coherence tomography (OCT) probe for directly monitoring of the RFA procedure with OCT images in real time. The integrated RFA/OCT probe is modified from a standard commercial RFA catheter, and a newly designed and fabricated miniature forward-viewing cone-scanning OCT probe is integrated into the modified probe. The OCT system is verified with the human finger images, and the results show the integrated RFA/OCT probe can acquire high quality OCT images. The radiofrequency energy delivering function of the integrated probe is verified by comparing the RFA lesion sizes with standard commercial RFA probe. For the standard commercial probe, the average width and depth of the 10 lesions were 3.5 mm and 1.8 mm respectively. For the integrated RFA/OCT probe, the average width and depth of the 10 lesions were 3.6 mm and 1.7 mm respectively. The lesions created by the two probes are indistinguishable in size. This demonstrates that our glass window in the integrated probe has little effect on the RF energy delivery. And the integrated probe is used to monitoring the cardiac RFA procedure in real time. The results show that the RFA lesion formation can be confirmed by the loss of birefringence in the heart tissue. The system can potentially in vivo image of the cardiac wall to aid RFA therapy for cardiac arrhythmias.

  10. Circuit weight training and cardiac morphology: a trial with magnetic resonance imaging.

    PubMed

    Camargo, M D; Stein, R; Ribeiro, J P; Schvartzman, P R; Rizzatti, M O; Schaan, B D

    2008-02-01

    Aerobic training (AT) and circuit weight training (CWT) improve peak oxygen uptake (VO(2)peak). During CWT the circulatory system is exposed to higher pressure, which could induce left ventricle morphological adaptations, possibly distinct from those derived from aerobic training. To compare the effects of aerobic training and CWT upon morphological and functional cardiac adaptations detected by magnetic resonance imaging. Twenty healthy sedentary individuals were randomly assigned to participate in a 12-week programme of aerobic training (n = 6), CWR (n = 7) or no intervention (n = 7, controls). Training programmes consisted of 36 sessions, 35 min each, 3 times per week, at 70% of maximal heart rate, and CWT included series of resistance exercises performed at 60% of 1 maximal repetition. Cardiopulmonary exercise testing and cardiac magnetic resonance imaging were performed before and after the intervention. There was a similar improvement in VO(2)peak following aerobic training (mean (SD) increment: 12 (4)%) and CWT (12 (4)%), while there was no change in the control group. Aerobic training (12 (6)%) and CWT (16 (5)%) improved strength in the lower limbs, and only CWT resulted in improvement of 13 (4)% in the strength of the upper limbs. However, there were no detectable changes in left ventricular mass, end-diastolic volume, stroke volume or ejection fraction. In previously sedentary individuals, short-term CWT and aerobic training induce similar improvement in functional capacity without any adaptation in cardiac morphology detectable by cardiac magnetic resonance imaging.

  11. A STUDY OF CHANGES IN DEFORMATION AND METABOLISM IN LEFT VENTRICLE AS A FUNCTION OF HYPERTROPHY IN SPONTANEOUS HYPERTENSIVE RATS USING MICROPET TECHNOLOGY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gullberg, Grant, T; Huesman, Ronald, H; Reutter, Bryan, W

    Problem: In the case of hypertrophy caused by pressure overload (hypertension) there is an increase in cardiac mass and modification cardiac metabolism. Aim: This study was designed to study the changes in glucose metabolism, ejection fraction, and deformation in the left ventricle with the progression of hypertrophy in spontaneous hypertensive rats (SHR). Methods: Dynamic PET data were acquired using the microPET II at UC Davis. Two rats were imaged at 10-week intervals for 18 months. Each time a dose of approximately 1- 1.5 mCi of F-18-FDG was injected into a normotensive Wistar Kyoto (WKY) rat and the same dose wasmore » injected into a SHR rat. Each rat was imaged using a gated dynamic acquisition for 80 minutes acquiring list mode data with cardiac gating of approximately 600-900 million total counts. For the analysis of glucose of metabolism, the list mode data were histogrammed into a dynamic sequence (42 frames over 80 mins). For each time frame, projection data of 1203 140x210 sinograms of 0.582 mm bins were formed by summing the last three gates before and one after the R-wave trigger to correspond to the diastolic phase of the cardiac cycle. Dynamic sequences of 128x128x83 matrices of 0.4x0.4x0.582 mm3 voxels in x, y, and z were reconstructed using an iterative MAP reconstruction which used a prior that penalized the high frequency components of the reconstruction using appropriate weighting between 26 nearest neighboring voxels. Time activity curves were generated from the dynamic reconstructed sequence for the blood and left ventricular tissue regions of interest which were fit to a 2-compartment model to obtain a least squares fit for the kinetic parameters. For the analysis of deformation, the list mode data were histogrammed into 8 gates of the cardiac cycle, each gate was the total sum of the later 60 mins of the 80 min acquisition. Images of 128x128x83 matrices for each gate were reconstructed using the same iterative MAP reconstruction used to reconstruct the dynamic sequence. The in-plane image dimensions were doubled to 256x256x83 in order to increase the resolution for the Warping analyses. These image data sets were then cropped to 128x128x83. The end-systolic image data sets were designated as the template images and the end-diastole image data sets were designated as the target images, thus providing an analysis of the diastolic relaxation and filling phases of the cardiac cycle. The template images were manually segmented to create surface definitions representing the epi- and endocardial surfaces. Finite element models of the left ventricles were created using the segmented surfaces and defining a transversely isotropic material with fiber angles varying from the epicardial surface to the endocardial surface. A Warping analyses was performed to obtain the LV strain tensor and fiber stretch distributions. Results: In one study, the average first principal Green-Lagrange strain, fiber stretch, ejection fraction, and metabolic rate of F-18-FDG was 0.22, 1.08, 80%, 0.1 for the WKY rat and 0.16, 1.06, 50%, 0.25 for the SHR rat, respectively. These same rats studied a year later presented with a metabolic rate of F-18-FDG of 0.11 and 0.25 for the WKY and SHR, respectively. A follow-up study the average strain (n=10) and ejection fraction (n=18) was 0.21, 72.7% for WKY and 0.17, 69.8% for the SHR, respectively. Conclusion: In the case of pressure overload there is an increased reliance on carbohydrate oxidation in an attempt to maintain contractile function.« less

  12. Marketing cardiac CT programs.

    PubMed

    Scott, Jason

    2010-01-01

    There are two components of cardiac CT discussed in this article: coronary artery calcium scoring (CACS) and coronary computed tomography angiography (CCTA).The distinctive advantages of each CT examination are outlined. In order to ensure a successful cardiac CT program, it is imperative that imaging facilities market their cardiac CT practices effectively in order to gain a competitive advantage in this valuable market share. If patients receive quality care by competent individuals, they are more likely to recommend the facility's cardiac CT program. Satisfied patients will also be more willing to come back for any further testing.

  13. Cardiac CT for myocardial ischaemia detection and characterization--comparative analysis.

    PubMed

    Bucher, A M; De Cecco, C N; Schoepf, U J; Wang, R; Meinel, F G; Binukrishnan, S R; Spearman, J V; Vogl, T J; Ruzsics, B

    2014-11-01

    The assessment of patients presenting with symptoms of myocardial ischaemia remains one of the most common and challenging clinical scenarios faced by physicians. Current imaging modalities are capable of three-dimensional, functional and anatomical views of the heart and as such offer a unique contribution to understanding and managing the pathology involved. Evidence has accumulated that visual anatomical coronary evaluation does not adequately predict haemodynamic relevance and should be complemented by physiological evaluation, highlighting the importance of functional assessment. Technical advances in CT technology over the past decade have progressively moved cardiac CT imaging into the clinical workflow. In addition to anatomical evaluation, cardiac CT is capable of providing myocardial perfusion parameters. A variety of CT techniques can be used to assess the myocardial perfusion. The single energy first-pass CT and dual energy first-pass CT allow static assessment of myocardial blood pool. Dynamic cardiac CT imaging allows quantification of myocardial perfusion through time-resolved attenuation data. CT-based myocardial perfusion imaging (MPI) is showing promising diagnostic accuracy compared with the current reference modalities. The aim of this review is to present currently available myocardial perfusion techniques with a focus on CT imaging in light of recent clinical investigations. This article provides a comprehensive overview of currently available CT approaches of static and dynamic MPI and presents the results of corresponding clinical trials.

  14. A Magnetic Resonance Imaging-Conditional External Cardiac Defibrillator for Resuscitation Within the Magnetic Resonance Imaging Scanner Bore.

    PubMed

    Schmidt, Ehud J; Watkins, Ronald D; Zviman, Menekhem M; Guttman, Michael A; Wang, Wei; Halperin, Henry A

    2016-10-01

    Subjects undergoing cardiac arrest within a magnetic resonance imaging (MRI) scanner are currently removed from the bore and then from the MRI suite, before the delivery of cardiopulmonary resuscitation and defibrillation, potentially increasing the risk of mortality. This precludes many higher-risk (acute ischemic and acute stroke) patients from undergoing MRI and MRI-guided intervention. An MRI-conditional cardiac defibrillator should enable scanning with defibrillation pads attached and the generator ON, enabling application of defibrillation within the seconds of MRI after a cardiac event. An MRI-conditional external defibrillator may improve patient acceptance for MRI procedures. A commercial external defibrillator was rendered 1.5 Tesla MRI-conditional by the addition of novel radiofrequency filters between the generator and commercial disposable surface pads. The radiofrequency filters reduced emission into the MRI scanner and prevented cable/surface pad heating during imaging, while preserving all the defibrillator monitoring and delivery functions. Human volunteers were imaged using high specific absorption rate sequences to validate MRI image quality and lack of heating. Swine were electrically fibrillated (n=4) and thereafter defibrillated both outside and inside the MRI bore. MRI image quality was reduced by 0.8 or 1.6 dB, with the generator in monitoring mode and operating on battery or AC power, respectively. Commercial surface pads did not create artifacts deeper than 6 mm below the skin surface. Radiofrequency heating was within US Food and Drug Administration guidelines. Defibrillation was completely successful inside and outside the MRI bore. A prototype MRI-conditional defibrillation system successfully defibrillated in the MRI without degrading the image quality or increasing the time needed for defibrillation. It can increase patient acceptance for MRI procedures. © 2016 American Heart Association, Inc.

  15. Changing Utilization of Noninvasive Diagnostic Imaging Over 2 Decades: An Examination Family-Focused Analysis of Medicare Claims Using the Neiman Imaging Types of Service Categorization System.

    PubMed

    Rosman, David A; Duszak, Richard; Wang, Wenyi; Hughes, Danny R; Rosenkrantz, Andrew B

    2018-02-01

    The objective of our study was to use a new modality and body region categorization system to assess changing utilization of noninvasive diagnostic imaging in the Medicare fee-for-service population over a recent 20-year period (1994-2013). All Medicare Part B Physician Fee Schedule services billed between 1994 and 2013 were identified using Physician/Supplier Procedure Summary master files. Billed codes for diagnostic imaging were classified using the Neiman Imaging Types of Service (NITOS) coding system by both modality and body region. Utilization rates per 1000 beneficiaries were calculated for families of services. Among all diagnostic imaging modalities, growth was greatest for MRI (+312%) and CT (+151%) and was lower for ultrasound, nuclear medicine, and radiography and fluoroscopy (range, +1% to +31%). Among body regions, service growth was greatest for brain (+126%) and spine (+74%) imaging; showed milder growth (range, +18% to +67%) for imaging of the head and neck, breast, abdomen and pelvis, and extremity; and showed slight declines (range, -2% to -7%) for cardiac and chest imaging overall. The following specific imaging service families showed massive (> +100%) growth: cardiac CT, cardiac MRI, and breast MRI. NITOS categorization permits identification of temporal shifts in noninvasive diagnostic imaging by specific modality- and region-focused families, providing a granular understanding and reproducible analysis of global changes in imaging overall. Service family-level perspectives may help inform ongoing policy efforts to optimize imaging utilization and appropriateness.

  16. Low-Contrast and Low-Radiation Dose Protocol in Cardiac Computed Tomography: Usefulness of Low Tube Voltage and Knowledge-Based Iterative Model Reconstruction Algorithm.

    PubMed

    Iyama, Yuji; Nakaura, Takeshi; Yokoyama, Koichi; Kidoh, Masafumi; Harada, Kazunori; Oda, Seitaro; Tokuyasu, Shinichi; Yamashita, Yasuyuki

    This study aimed to evaluate the feasibility of a low contrast, low-radiation dose protocol of 80-peak kilovoltage (kVp) with prospective electrocardiography-gated cardiac computed tomography (CT) using knowledge-based iterative model reconstruction (IMR). Thirty patients underwent an 80-kVp prospective electrocardiography-gated cardiac CT with low-contrast agent (222-mg iodine per kilogram of body weight) dose. We also enrolled 30 consecutive patients who were scanned with a 120-kVp cardiac CT with filtered back projection using the standard contrast agent dose (370-mg iodine per kilogram of body weight) as a historical control group. We evaluated the radiation dose for the 2 groups. The 80-kVp images were reconstructed with filtered back projection (protocol A), hybrid iterative reconstruction (HIR, protocol B), and IMR (protocol C). We compared CT numbers, image noise, and contrast-to-noise ratio among 120-kVp protocol, protocol A, protocol B, and protocol C. In addition, we compared the noise reduction rate between HIR and IMR. Two independent readers compared image contrast, image noise, image sharpness, unfamiliar image texture, and overall image quality among the 4 protocols. The estimated effective dose (ED) of the 80-kVp protocol was 74% lower than that of the 120-kVp protocol (1.4 vs 5.4 mSv). The contrast-to-noise ratio of protocol C was significantly higher than that of protocol A. The noise reduction rate of IMR was significantly higher than that of HIR (P < 0.01). There was no significant difference in almost all qualitative image quality between 120-kVp protocol and protocol C except for image contrast. A 80-kVp protocol with IMR yields higher image quality with 74% decreased radiation dose and 40% decreased contrast agent dose as compared with a 120-kVp protocol, while decreasing more image noise compared with the 80-kVp protocol with HIR.

  17. Application of the Karhunen-Loeve transform temporal image filter to reduce noise in real-time cardiac cine MRI

    NASA Astrophysics Data System (ADS)

    Ding, Yu; Chung, Yiu-Cho; Raman, Subha V.; Simonetti, Orlando P.

    2009-06-01

    Real-time dynamic magnetic resonance imaging (MRI) typically sacrifices the signal-to-noise ratio (SNR) to achieve higher spatial and temporal resolution. Spatial and/or temporal filtering (e.g., low-pass filtering or averaging) of dynamic images improves the SNR at the expense of edge sharpness. We describe the application of a temporal filter for dynamic MR image series based on the Karhunen-Loeve transform (KLT) to remove random noise without blurring stationary or moving edges and requiring no training data. In this paper, we present several properties of this filter and their effects on filter performance, and propose an automatic way to find the filter cutoff based on the autocorrelation of the eigenimages. Numerical simulation and in vivo real-time cardiac cine MR image series spanning multiple cardiac cycles acquired using multi-channel sensitivity-encoded MRI, i.e., parallel imaging, are used to validate and demonstrate these properties. We found that in this application, the noise standard deviation was reduced to 42% of the original with no apparent image blurring by using the proposed filter cutoff. Greater noise reduction can be achieved by increasing the length of the image series. This advantage of KLT filtering provides flexibility in the form of another scan parameter to trade for SNR.

  18. Cardiac SPECT/CCTA hybrid imaging : One answer to two questions?

    PubMed

    Kaufmann, P A; Buechel, R R

    2016-08-01

    Noninvasive cardiac imaging has witnessed tremendous advances in the recent past, particularly with regard to coronary computed tomography angiography (CCTA) where substantial improvements in image quality have been achieved while at the same time patients' radiation dose exposure has been reduced to the sub-millisievert range. Similarly, for single-photon emission computed tomography (SPECT) the introduction of novel cadmium-zinc-telluride-based semiconductor detectors has significantly improved system sensitivity and image quality, enabling fast image acquisition within less than 2-3 min or reduction of radiation dose exposure to less than 5 mSv. However, neither imaging modality alone is able to fully cover the two aspects of coronary artery disease (CAD), that is, morphology and function. Both modalities have distinct advantages and shortcomings: While CCTA may prove a superb modality for excluding CAD through its excellent negative predictive value, it does not allow for assessment of hemodynamic relevance if obstructive coronary lesions are detected. Conversely, SPECT myocardial perfusion imaging cannot provide any information on the presence or absence of subclinical coronary atherosclerosis. This article aims to highlight the great potential of cardiac hybrid imaging that allows for a comprehensive evaluation of CAD through combination of both morphological and functional information by fusing SPECT with CCTA.

  19. Standardised imaging technique for guided M-mode and Doppler echocardiography in the horse.

    PubMed

    Long, K J; Bonagura, J D; Darke, P G

    1992-05-01

    Eighteen echocardiographic images useful for diagnostic imaging, M-mode echocardiography, and Doppler echocardiography of the equine heart were standardised by relating the position of the axial beam to various intracardiac landmarks. The transducer orientation required for each image was recorded in 14 adult horses by describing the degree of sector rotation and the orientation of the axial beam relative to the thorax. Repeatable images could be obtained within narrow limits of angulation and rotation for 14 of the 18 standardised images evaluated. Twenty-seven National Hunt horses were subsequently examined using this standardised technique. Selected cardiac dimensions were measured from two-dimensional and guided M-mode studies. Satisfactory results were achieved in 26 of the 27 horses. There was no linear correlation between any of the measured cardiac values and bodyweight. There was no significant difference between measurements taken from the left and the right hemithorax. Six horses were imaged on three consecutive days to assess the repeatability of the measurements. No significant difference was found between measurements obtained on different days. This study demonstrates a method for standardised echocardiographic evaluation of the equine heart that is repeatable, valuable for teaching techniques of equine echocardiography, applicable for diagnostic imaging and quantification of cardiac size, and useful for the evaluation of blood-flow patterns by Doppler ultrasound.

  20. Effect of autogenic training on cardiac autonomic nervous activity in high-risk fire service workers for posttraumatic stress disorder.

    PubMed

    Mitani, Satoko; Fujita, Masatoshi; Sakamoto, Satoko; Shirakawa, Taro

    2006-05-01

    We investigated the effect of autogenic training (AT) on cardiac autonomic nervous activity in fire services workers with the use of the questionnaire of the Japanese-language version of Impact of Event Scale-Revised (IES-R-J) and indexes of heart rate variability. We studied 22 male fire services workers who were divided into posttraumatic stress disorder (PTSD)-related stress group (n=10) and control group (n=12). They underwent AT twice or three times a week for 2 months. Posttraumatic stress disorder-related stress group showed a significantly higher cardiac sympathetic nervous activity and a significantly lower cardiac parasympathetic nervous activity than control group at baseline. Autogenic training significantly decreased cardiac sympathetic nervous activity and significantly increased cardiac parasympathetic nervous activity in both groups. These changes were accompanied by a significant decrease in the total points of IES-R-J. Autogenic training is effective for ameliorating the disturbance of cardiac autonomic nervous activity and psychological issues secondary to PTSD.

  1. Toward computer-assisted image-guided congenital heart defect repair: an initial phantom analysis.

    PubMed

    Kwartowitz, David M; Mefleh, Fuad N; Baker, G Hamilton

    2017-10-01

    Radiation exposure in interventional cardiology is an important consideration, due to risk of cancer and other morbidity to the patient and clinical staff. Cardiac catheterizations rely heavily on fluoroscopic imaging exposing both patient and clinician to ionizing radiation. An image-guided surgery system capable of facilitating cardiac catheterizations was developed and tested to evaluate dose reduction. Several electromagnetically tracked tools were constructed specifically a 7-Fr catheter with five 5-degree-of-freedom magnetic seeds. Catheter guidance was accomplished using our image guidance system Kit for Navigation by Image-Focused Exploration and fluoroscopy alone. A cardiac phantom was designed and 3D printed to validate the image guidance procedure. In mock procedures, an expert clinician guided and deployed an occluder across the septal defect of the phantom heart. The image guidance method resulted in a dose of 1.26 mSv of radiation dose per procedure, while traditional guidance resulted in a dose of 3.33 mSv. Average overall dose savings for the image-guided method was nearly 2.07 mSv or 62 %. The work showed significant ([Formula: see text]) decrease in radiation dose with use of image guidance methods at the expense of a modest increase in procedure time. This study lays the groundwork for further exploration of image guidance applications in pediatric cardiology.

  2. Advances in the development of an imaging device for plaque measurement in the area of the carotid artery.

    PubMed

    Ličev, Lačezar; Krumnikl, Michal; Škuta, Jaromír; Babiuch, Marek; Farana, Radim

    2014-03-04

    This paper describes the advances in the development and subsequent testing of an imaging device for three-dimensional ultrasound measurement of atherosclerotic plaque in the carotid artery. The embolization from the atherosclerotic carotid plaque is one of the most common causes of ischemic stroke and, therefore, we consider the measurement of the plaque as extremely important. The paper describes the proposed hardware for enhancing the standard ultrasonic probe to provide a possibility of accurate probe positioning and synchronization with the cardiac activity, allowing the precise plaque measurements that were impossible with the standard equipment. The synchronization signal is derived from the output signal of the patient monitor (electrocardiogram (ECG)), processed by a microcontroller-based system, generating the control commands for the linear motion moving the probe. The controlling algorithm synchronizes the movement with the ECG waveform to obtain clear images not disturbed by the heart activity.

  3. Cardiac T1 Imaging

    PubMed Central

    Jerosch-Herold, Michael; Kwong, Raymond Y.

    2014-01-01

    T1 mapping of the heart has evolved into a valuable tool to evaluate myocardial tissue properties, with or without contrast injection, including assessment of myocardial edema and free water content, extra-cellular volume (expansion), and most recently cardiomyocyte hypertrophy. The MRI pulse sequence techniques developed for these applications have had to address at least two important considerations for cardiac applications: measure magnetization inversion recoveries during cardiac motion with sufficient temporal resolution for the shortest expected T1 values, and, secondly, obtain these measurements within a time during which a patient can comfortably suspend breathing. So-called Look-Locker techniques, and variants thereof, which all sample multiple points of a magnetization recovery after each magnetization preparation have therefore become a mainstay in this field. The rapid pace of advances and new findings based on cardiac T1 mapping for assessment of diffuse fibrosis, or myocardial edema show that these techniques enrich the capabilities of MRI for myocardial tissue profiling, which is arguably unmatched by other cardiac imaging modalities. PMID:24509619

  4. The dynamic natural history of cerebral aneurysms from cardiac myxomas: A review of the natural history of myxomatous aneurysms.

    PubMed

    Flores, Paloma Largo; Haglund, Felix; Bhogal, Pervinder; Yeo Leong Litt, Leonard; Södermann, Michael

    2018-06-01

    We describe two contrasting patients with multiple cerebral aneurysms and a previous history of resected cardiac myxomas with no cardiac recurrence on follow-up echocardiography. Both patients presented with stroke- like symptoms; one with a left visual defect and the other with right hemiplegia. Magnetic resonance imaging of the brain of both patients showed the presence of multiple cerebral aneurysms that was later confirmed on conventional angiography. Both patients' aneurysms were managed conservatively. Serial angiograms were performed during their follow-up, which spanned several years. One patient's aneurysms remained static while the evolution of the other patient's aneurysms displayed a dynamic quality with some increasing in size while others diminished. This is the first description in which some aneurysms progressed while others regressed simultaneously in the same patient. Aneurysms in patients with a history of cardiac myxoma can be active years after primary tumor resection and it is difficult to predict how they will develop. We reviewed the literature of all patients with multiple myxomatous aneurysms who were treated conservatively to better understand the natural history of this rare disease. Long-term follow-up of these patients may be necessary.

  5. Isn't it time to abandon cine film?

    PubMed

    Holmes, D R; Wondrow, M A; Gray, J E

    1990-05-01

    Cine has served our needs well since the early 1950s. For the first time, it allowed recording of motion studies of the cardiac structures on film. The cine technique has been standardized over the years, both the camera and the display. Cine filming techniques, however, have not advanced, except for new film products with faster emulsions and better-quality films. Video electronic imaging has made rapid advancements. These were prompted by the broadcast industry when the requirements for color were developed in the 1960s and by the advent of new recording techniques that provided a very stable video time base from analog tape recorders. The medical field has been able to capitalize on these developments and to produce some of our own that have not been applied in the broadcast world. These include pulsed progressive 525-line video acquisition of cardiac images in the cardiac catheterization laboratory. We also have been able to capitalize on the improved detector technology that the broadcast world has developed, such as the plumbicon pickup tubes, which produce images with very little lag and so provide images with improved resolution. These developments also have enabled us to reduce radiation to both the patient and the laboratory personnel, especially with implementation of the pulsed progressive acquisition, with which the dose has been reduced 50%. With the advent of interventional procedures in the cardiac catheterization laboratory, the need to assess images immediately cannot be fulfilled by cine filming because of the requirement for the processing of the film with its inherent delays. Quantification of cardiac structures is required to assess the outcome of interventional techniques.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. Aviator's Heart: A Case of Athlete's Heart in an Active Duty Male Naval Aviator.

    PubMed

    Ryaboy, Ilya V; Watts, James A; Barnwell, Megan L

    2018-05-31

    Athlete's heart is the condition of cardiac remodeling as a result of physiologic stress induced by regular strenuous physical activity by professional or elite amateur individuals. The literature describes several characteristics of the athletic heart, including left ventricular hypertrophy, increased left ventricular mass, right ventricular dilatation, atrial enlargement, electrocardiographic changes, and abnormalities on cardiac magnetic resonance imaging. We present a case of athletic heart in an exceptionally physically fit active duty naval aviator who experienced syncope and underwent extensive cardiac testing. He was found to have borderline hypertrophic changes as well as delayed gadolinium enhancement initially concerning for myocarditis. Cardiopulmonary exercise testing revealed an exercise capacity of 120% above the maximum measurable value for his age and gender. He was then diagnosed with athlete's heart and released to active duty with no limitations to his flight status. A challenge is posed to the practicing clinician in differentiating the athletic heart from the heart of an athlete suffering from underlying pathophysiology. Athlete's heart is an elusive diagnosis and may be associated with findings concerning for more insidious pathology, including hypertrophic cardiomyopathy and dilated cardiomyopathy. Additionally, patients with athlete's heart have been noted to have delayed gadolinium enhancement similar to that seen in patients with a history of myocarditis; the clinical significance of this finding is yet to be fully elucidated. In a military setting, distinguishing the heart of the healthy and athletic service member from the unfortunate one who has cardiomyopathy remains an important clinical distinction warranting further study.

  7. Myocardial Tissue Characterization by Magnetic Resonance Imaging

    PubMed Central

    Ferreira, Vanessa M.; Piechnik, Stefan K.; Robson, Matthew D.; Neubauer, Stefan

    2014-01-01

    Cardiac magnetic resonance (CMR) imaging is a well-established noninvasive imaging modality in clinical cardiology. Its unsurpassed accuracy in defining cardiac morphology and function and its ability to provide tissue characterization make it well suited for the study of patients with cardiac diseases. Late gadolinium enhancement was a major advancement in the development of tissue characterization techniques, allowing the unique ability of CMR to differentiate ischemic heart disease from nonischemic cardiomyopathies. Using T2-weighted techniques, areas of edema and inflammation can be identified in the myocardium. A new generation of myocardial mapping techniques are emerging, enabling direct quantitative assessment of myocardial tissue properties in absolute terms. This review will summarize recent developments involving T1-mapping and T2-mapping techniques and focus on the clinical applications and future potential of these evolving CMR methodologies. PMID:24576837

  8. Improving Low-dose Cardiac CT Images based on 3D Sparse Representation

    NASA Astrophysics Data System (ADS)

    Shi, Luyao; Hu, Yining; Chen, Yang; Yin, Xindao; Shu, Huazhong; Luo, Limin; Coatrieux, Jean-Louis

    2016-03-01

    Cardiac computed tomography (CCT) is a reliable and accurate tool for diagnosis of coronary artery diseases and is also frequently used in surgery guidance. Low-dose scans should be considered in order to alleviate the harm to patients caused by X-ray radiation. However, low dose CT (LDCT) images tend to be degraded by quantum noise and streak artifacts. In order to improve the cardiac LDCT image quality, a 3D sparse representation-based processing (3D SR) is proposed by exploiting the sparsity and regularity of 3D anatomical features in CCT. The proposed method was evaluated by a clinical study of 14 patients. The performance of the proposed method was compared to the 2D spares representation-based processing (2D SR) and the state-of-the-art noise reduction algorithm BM4D. The visual assessment, quantitative assessment and qualitative assessment results show that the proposed approach can lead to effective noise/artifact suppression and detail preservation. Compared to the other two tested methods, 3D SR method can obtain results with image quality most close to the reference standard dose CT (SDCT) images.

  9. High prevalence of cardiac hypertophy without detectable signs of fibrosis in patients with untreated active acromegaly: an in vivo study using magnetic resonance imaging.

    PubMed

    Bogazzi, Fausto; Lombardi, Massimo; Strata, Elisabetta; Aquaro, Giovanni; Di Bello, Vitantonio; Cosci, Chiara; Sardella, Chiara; Talini, Enrica; Martino, Enio

    2008-03-01

    Left ventricular (LV) hypertrophy and myocardial fibrosis are considered the main pathological features of acromegalic cardiomyopathy. The aim of the study was to evaluate the proportion of LV hypertrophy and the presence of fibrosis in acromegalic cardiomyopathy in vivo using cardiac magnetic resonance (CMR). Fourteen consecutive patients (eight women, mean age 46 +/- 10 years) with untreated active acromegaly were submitted to two-dimensional (2D) colour Doppler and integrated backscatter (IBS) echocardiography and CMR. LV volume, mass and wall thickness and myocardial tissue characterization (IBS and CMR). On echocardiography: mean LV mass (LVM) and LVM index (LVMi) were 209 +/- 48 g and 110 +/- 24 g/m(2), respectively; hypertrophy was revealed in five patients (36%); abnormal diastolic function [evaluated by isovolumic relaxation time (IVRT) or early (E) to late or atrial (A) peak velocities (E/A ratio)] was found in four patients (29%). Systolic function evaluated by measuring LV ejection fraction (LVEF) was normal (mean 72 +/- 12%) in all patients. Six patients (43%) had increased IBS (mean 57.4 +/- 6.2%). On CMR: mean LVM and LVMi were 151 +/- 17 g and 76 +/- 9 g/m(2), respectively; 10 patients (72%) had LV hypertrophy. Contrastographic delayed hyperenhancement was absent in all patients; on the contrary, mild enhancement was revealed in one patient. Systolic function was normal in all patients (LVEF 67 +/- 11%). LVMi was not related to serum IGF-1 concentrations or the estimated duration of disease. CMR is considered to be the gold standard for evaluating cardiac hypertrophy, fibrosis and systolic function. Using CMR, 72% patients with untreated active acromegaly had LV hypertrophy, which was only detected in 36% patients by echocardiography. However, cardiac fibrosis was absent in all patients irrespective of the estimated duration of disease. Although a very small increase in collagen content (as suggested by increased cardiac reflectivity at IBS), not detectable by CMR, could not be ruled out, it is unlikely that it would significantly affect cardiac function.

  10. Cardiac-restricted Overexpression of TRAF3 Interacting Protein 2 (TRAF3IP2) Results in Spontaneous Development of Myocardial Hypertrophy, Fibrosis, and Dysfunction *

    PubMed Central

    Sakamuri, Siva S. V. P.; Siddesha, Jalahalli M.; Saifudeen, Zubaida; Ma, Lixin; Siebenlist, Ulrich; Gardner, Jason D.; Chandrasekar, Bysani

    2016-01-01

    TRAF3IP2 (TRAF3 interacting protein 2; previously known as CIKS or Act1) is a key intermediate in the normal inflammatory response and the pathogenesis of various autoimmune and inflammatory diseases. Induction of TRAF3IP2 activates IκB kinase (IKK)/NF-κB, JNK/AP-1, and c/EBPβ and stimulates the expression of various inflammatory mediators with negative myocardial inotropic effects. To investigate the role of TRAF3IP2 in heart disease, we generated a transgenic mouse model with cardiomyocyte-specific TRAF3IP2 overexpression (TRAF3IP2-Tg). Echocardiography, magnetic resonance imaging, and pressure-volume conductance catheterization revealed impaired cardiac function in 2-month-old male transgenic (Tg) mice as evidenced by decreased ejection fraction, stroke volume, cardiac output, and peak ejection rate. Moreover, the male Tg mice spontaneously developed myocardial hypertrophy (increased heart/body weight ratio, cardiomyocyte cross-sectional area, GATA4 induction, and fetal gene re-expression). Furthermore, TRAF3IP2 overexpression resulted in the activation of IKK/NF-κB, JNK/AP-1, c/EBPβ, and p38 MAPK and induction of proinflammatory cytokines, chemokines, and extracellular matrix proteins in the heart. Although myocardial hypertrophy decreased with age, cardiac fibrosis (increased number of myofibroblasts and enhanced expression and deposition of fibrillar collagens) increased progressively. Despite these adverse changes, TRAF3IP2 overexpression did not result in cell death at any time period. Interestingly, despite increased mRNA expression, TRAF3IP2 protein levels and activation of its downstream signaling intermediates remained unchanged in the hearts of female Tg mice. The female Tg mice also failed to develop myocardial hypertrophy. In summary, these results demonstrate that overexpression of TRAF3IP2 in male mice is sufficient to induce myocardial hypertrophy, cardiac fibrosis, and contractile dysfunction. PMID:27466370

  11. Heart-Brain Interactions in the MR Environment: Characterization of the Ballistocardiogram in EEG Signals Collected During Simultaneous fMRI.

    PubMed

    Marino, Marco; Liu, Quanying; Del Castello, Mariangela; Corsi, Cristiana; Wenderoth, Nicole; Mantini, Dante

    2018-05-01

    The ballistocardiographic (BCG) artifact is linked to cardiac activity and occurs in electroencephalographic (EEG) recordings acquired inside the magnetic resonance (MR) environment. Its variability in terms of amplitude, waveform shape and spatial distribution over subject's scalp makes its attenuation a challenging task. In this study, we aimed to provide a detailed characterization of the BCG properties, including its temporal dependency on cardiac events and its spatio-temporal dynamics. To this end, we used high-density EEG data acquired during simultaneous functional MR imaging in six healthy volunteers. First, we investigated the relationship between cardiac activity and BCG occurrences in the EEG recordings. We observed large variability in the delay between ECG and subsequent BCG events (ECG-BCG delay) across subjects and non-negligible epoch-by-epoch variations at the single subject level. The inspection of spatial-temporal variations revealed a prominent non-stationarity of the BCG signal. We identified five main BCG waves, which were common across subjects. Principal component analysis revealed two spatially distinct patterns to explain most of the variance (85% in total). These components are possibly related to head rotation and pulse-driven scalp expansion, respectively. Our results may inspire the development of novel, more effective methods for the removal of the BCG, capable of isolating and attenuating artifact occurrences while preserving true neuronal activity.

  12. Rapid multislice T1 mapping of mouse myocardium: Application to quantification of manganese uptake in α-Dystrobrevin knockout mice.

    PubMed

    Jiang, Kai; Li, Wen; Li, Wei; Jiao, Sen; Castel, Laurie; Van Wagoner, David R; Yu, Xin

    2015-11-01

    The aim of this study was to develop a rapid, multislice cardiac T1 mapping method in mice and to apply the method to quantify manganese (Mn(2+)) uptake in a mouse model with altered Ca(2+) channel activity. An electrocardiography-triggered multislice saturation-recovery Look-Locker method was developed and validated both in vitro and in vivo. A two-dose study was performed to investigate the kinetics of T1 shortening, Mn(2+) relaxivity in myocardium, and the impact of Mn(2+) on cardiac function. The sensitivity of Mn(2+)-enhanced MRI in detecting subtle changes in altered Ca(2+) channel activity was evaluated in a mouse model with α-dystrobrevin knockout. Validation studies showed strong agreement between the current method and an established method. High Mn(2+) dose led to significantly accelerated T1 shortening. Heart rate decreased during Mn(2+) infusion, while ejection ratio increased slightly at the end of imaging protocol. No statistical difference in cardiac function was detected between the two dose groups. Mice with α-dystrobrevin knockout showed enhanced Mn(2+) uptake in vivo. In vitro patch-clamp study showed increased Ca(2+) channel activity. The saturation recovery method provides rapid T1 mapping in mouse hearts, which allowed sensitive detection of subtle changes in Mn(2+) uptake in α-dystrobrevin knockout mice. © 2014 Wiley Periodicals, Inc.

  13. Reflective lens-free imaging on high-density silicon microelectrode arrays for monitoring and evaluation of in vitro cardiac contractility

    PubMed Central

    Pauwelyn, Thomas; Stahl, Richard; Mayo, Lakyn; Zheng, Xuan; Lambrechts, Andy; Janssens, Stefan; Lagae, Liesbet; Reumers, Veerle; Braeken, Dries

    2018-01-01

    The high rate of drug attrition caused by cardiotoxicity is a major challenge for drug development. Here, we developed a reflective lens-free imaging (RLFI) approach to non-invasively record in vitro cell deformation in cardiac monolayers with high temporal (169 fps) and non-reconstructed spatial resolution (352 µm) over a field-of-view of maximally 57 mm2. The method is compatible with opaque surfaces and silicon-based devices. Further, we demonstrated that the system can detect the impairment of both contractility and fast excitation waves in cardiac monolayers. Additionally, the RLFI device was implemented on a CMOS-based microelectrode array to retrieve multi-parametric information of cardiac cells, thereby offering more in-depth analysis of drug-induced (cardiomyopathic) effects for preclinical cardiotoxicity screening applications. PMID:29675322

  14. Nuclear cardiac imaging: Principles and applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iskandrian, A.S.

    1987-01-01

    This book is divided into 11 chapters. The first three provide a short description of the instrumentation, radiopharmaceuticals, and imaging techniques used in nuclear cardiology. Chapter 4 discusses exercise testing. Chapter 5 gives the theory, technical aspects, and interpretations of thallium-201 myocardial imaging and radionuclide ventriculography. The remaining chapters discuss the use of these techniques in patients with coronary artery disease, acute myocardial infarction, valvular heart disease, and other forms of cardiac disease. The author intended to emphasize the implications of nuclear cardiology procedures on patient care management and to provide a comprehensive bibliography.

  15. Respiratory motion compensated overlay of surface models from cardiac MR on interventional x-ray fluoroscopy for guidance of cardiac resynchronization therapy procedures

    NASA Astrophysics Data System (ADS)

    Manzke, R.; Bornstedt, A.; Lutz, A.; Schenderlein, M.; Hombach, V.; Binner, L.; Rasche, V.

    2010-02-01

    Various multi-center trials have shown that cardiac resynchronization therapy (CRT) is an effective procedure for patients with end-stage drug invariable heart failure (HF). Despite the encouraging results of CRT, at least 30% of patients do not respond to the treatment. Detailed knowledge of the cardiac anatomy (coronary venous tree, left ventricle), functional parameters (i.e. ventricular synchronicity) is supposed to improve CRT patient selection and interventional lead placement for reduction of the number of non-responders. As a pre-interventional imaging modality, cardiac magnetic resonance (CMR) imaging has the potential to provide all relevant information. With functional information from CMR optimal implantation target sites may be better identified. Pre-operative CMR could also help to determine whether useful vein target segments are available for lead placement. Fused with X-ray, the mainstay interventional modality, improved interventional guidance for lead-placement could further help to increase procedure outcome. In this contribution, we present novel and practicable methods for a) pre-operative functional and anatomical imaging of relevant cardiac structures to CRT using CMR, b) 2D-3D registration of CMR anatomy and functional meshes with X-ray vein angiograms and c) real-time capable breathing motion compensation for improved fluoroscopy mesh overlay during the intervention based on right ventricular pacer lead tracking. With these methods, enhanced interventional guidance for left ventricular lead placement is provided.

  16. Depression is associated with increased vagal withdrawal during unpleasant emotional imagery after cardiac surgery.

    PubMed

    Patron, Elisabetta; Messerotti Benvenuti, Simone; Favretto, Giuseppe; Gasparotto, Renata; Palomba, Daniela

    2015-05-01

    The aim of this study was to examine the influence of depression on heart rate and heart rate variability (HRV) during emotional imagery in patients after cardiac surgery. Based on the scores of the Center for Epidemiological Studies of Depression (CES-D) scale, 28 patients after cardiac surgery were assigned either to the group with depression (CES-D scores ≥ 16; N = 14) or the one without depression (CES-D scores<16; N = 14). Each patient completed a rest period and an emotional imagery including pleasant, neutral and unpleasant scripts. Inter-beat intervals (IBIs) and HRV were measured during the entire protocol. Compared to nondepressed patients, those with depression had greater reductions in high frequency expressed in normalized units (HF n.u.) during the imaging of the unpleasant script (p = .003, Cohen's d = 1.34). Moreover, HF n.u. were lower during the imaging of the unpleasant script than the pleasant one in depressed patients only (p = .020, Cohen's d = 0.55). CES-D scores were also inversely correlated with residualized changes in IBIs (r = -.38, p = .045) and HF n.u. (r = -.49, p = .008) from rest to the imaging of the unpleasant script. The relationship between depression and increased vagal withdrawal during unpleasant emotional imagery extends to patients after cardiac surgery. The present study suggests that increased vagal withdrawal to negative emotions in patients after cardiac surgery may mediate the conferral of cardiac risk by depression. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. A spectral approach for the quantitative description of cardiac collagen network from nonlinear optical imaging.

    PubMed

    Masè, Michela; Cristoforetti, Alessandro; Avogaro, Laura; Tessarolo, Francesco; Piccoli, Federico; Caola, Iole; Pederzolli, Carlo; Graffigna, Angelo; Ravelli, Flavia

    2015-01-01

    The assessment of collagen structure in cardiac pathology, such as atrial fibrillation (AF), is essential for a complete understanding of the disease. This paper introduces a novel methodology for the quantitative description of collagen network properties, based on the combination of nonlinear optical microscopy with a spectral approach of image processing and analysis. Second-harmonic generation (SHG) microscopy was applied to atrial tissue samples from cardiac surgery patients, providing label-free, selective visualization of the collagen structure. The spectral analysis framework, based on 2D-FFT, was applied to the SHG images, yielding a multiparametric description of collagen fiber orientation (angle and anisotropy indexes) and texture scale (dominant wavelength and peak dispersion indexes). The proof-of-concept application of the methodology showed the capability of our approach to detect and quantify differences in the structural properties of the collagen network in AF versus sinus rhythm patients. These results suggest the potential of our approach in the assessment of collagen properties in cardiac pathologies related to a fibrotic structural component.

  18. Dynamic single photon emission computed tomography—basic principles and cardiac applications

    PubMed Central

    Gullberg, Grant T; Reutter, Bryan W; Sitek, Arkadiusz; Maltz, Jonathan S; Budinger, Thomas F

    2011-01-01

    The very nature of nuclear medicine, the visual representation of injected radiopharmaceuticals, implies imaging of dynamic processes such as the uptake and wash-out of radiotracers from body organs. For years, nuclear medicine has been touted as the modality of choice for evaluating function in health and disease. This evaluation is greatly enhanced using single photon emission computed tomography (SPECT), which permits three-dimensional (3D) visualization of tracer distributions in the body. However, to fully realize the potential of the technique requires the imaging of in vivo dynamic processes of flow and metabolism. Tissue motion and deformation must also be addressed. Absolute quantification of these dynamic processes in the body has the potential to improve diagnosis. This paper presents a review of advancements toward the realization of the potential of dynamic SPECT imaging and a brief history of the development of the instrumentation. A major portion of the paper is devoted to the review of special data processing methods that have been developed for extracting kinetics from dynamic cardiac SPECT data acquired using rotating detector heads that move as radiopharmaceuticals exchange between biological compartments. Recent developments in multi-resolution spatiotemporal methods enable one to estimate kinetic parameters of compartment models of dynamic processes using data acquired from a single camera head with slow gantry rotation. The estimation of kinetic parameters directly from projection measurements improves bias and variance over the conventional method of first reconstructing 3D dynamic images, generating time–activity curves from selected regions of interest and then estimating the kinetic parameters from the generated time–activity curves. Although the potential applications of SPECT for imaging dynamic processes have not been fully realized in the clinic, it is hoped that this review illuminates the potential of SPECT for dynamic imaging, especially in light of new developments that enable measurement of dynamic processes directly from projection measurements. PMID:20858925

  19. TOPICAL REVIEW: Dynamic single photon emission computed tomography—basic principles and cardiac applications

    NASA Astrophysics Data System (ADS)

    Gullberg, Grant T.; Reutter, Bryan W.; Sitek, Arkadiusz; Maltz, Jonathan S.; Budinger, Thomas F.

    2010-10-01

    The very nature of nuclear medicine, the visual representation of injected radiopharmaceuticals, implies imaging of dynamic processes such as the uptake and wash-out of radiotracers from body organs. For years, nuclear medicine has been touted as the modality of choice for evaluating function in health and disease. This evaluation is greatly enhanced using single photon emission computed tomography (SPECT), which permits three-dimensional (3D) visualization of tracer distributions in the body. However, to fully realize the potential of the technique requires the imaging of in vivo dynamic processes of flow and metabolism. Tissue motion and deformation must also be addressed. Absolute quantification of these dynamic processes in the body has the potential to improve diagnosis. This paper presents a review of advancements toward the realization of the potential of dynamic SPECT imaging and a brief history of the development of the instrumentation. A major portion of the paper is devoted to the review of special data processing methods that have been developed for extracting kinetics from dynamic cardiac SPECT data acquired using rotating detector heads that move as radiopharmaceuticals exchange between biological compartments. Recent developments in multi-resolution spatiotemporal methods enable one to estimate kinetic parameters of compartment models of dynamic processes using data acquired from a single camera head with slow gantry rotation. The estimation of kinetic parameters directly from projection measurements improves bias and variance over the conventional method of first reconstructing 3D dynamic images, generating time-activity curves from selected regions of interest and then estimating the kinetic parameters from the generated time-activity curves. Although the potential applications of SPECT for imaging dynamic processes have not been fully realized in the clinic, it is hoped that this review illuminates the potential of SPECT for dynamic imaging, especially in light of new developments that enable measurement of dynamic processes directly from projection measurements.

  20. Ligands for SPECT and PET imaging of muscarinic-cholinergic receptors of the heart and brain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knapp, F.F. Jr.; McPherson, D.W.; Luo, H.

    1995-06-01

    Interest in the potential use of cerebral SPECT and PET imaging for determination of the density and activity of muscarinic-cholinergic receptors (mAChR) has been stimulated by the changes in these receptors which occur in many neurological diseases. In addition, the important involvement of mAChR in modulating negative inotropic cardiac activity suggests that such receptor ligands may have important applications in evaluation of changes which may occur in cardiac disease. In this paper, the properties of several key muscarinic receptor ligands being developed or which have been used for clinical SPECT and PET are discussed. In addition, the ORNL development ofmore » the new iodinated IQNP ligand based on QNB and the results of in vivo biodistribution studies in rats, in vitro competitive binding studies and ex vivo autoradiographic experiments are described. The use of radioiodinated IQNP may offer several advantages in comparison to IQNB because of its easy and high yield preparation and high brain uptake and the potential usefulness of the {open_quotes}partial{close_quotes} subtype selective IONP isomers. We also describe the development of new IQNP-type analogues which offer the opportunity for radiolabeling with positron-emitting radioisotopes (carbon-11, fluorine-18 and bromine-76) for potential use with PET.« less

Top