Using impedance cardiography with postural change to stratify patients with hypertension.
DeMarzo, Arthur P
2011-06-01
Early detection of cardiovascular disease in patients with hypertension could initiate appropriate treatment to control blood pressure and prevent the progression of cardiovascular disease. The goal of this study was to show how impedance cardiography waveform analysis with postural change can be used to detect subclinical cardiovascular disease in patients with high blood pressure. Patients with high blood pressure had impedance cardiography data obtained in two positions, standing upright and supine. In 50 adults, impedance cardiography indicated that all patients had abnormal data, with 44 (88%) having multiple abnormalities. Impedance cardiography showed 32 (64%) had ventricular dysfunction, 48 (96%) had vascular load abnormalities, 34 (68%) had hemodynamic abnormalities, 2 (4%) had hypovolemia, and 3 (6%) had hypervolemia. Hypertensive patients have diverse cardiovascular abnormalities that can be quantified by impedance cardiography. By stratifying patients with ventricular, vascular, and hemodynamic abnormalities, treatment could be customized based on the abnormal underlying mechanisms with the potential to rapidly control blood pressure, prevent progression of cardiovascular disease, and possibly reverse remodeling.
NASA Astrophysics Data System (ADS)
Peczalski, K.; Palko, T.; Wojciechowski, D.; Dunajski, Z.; Kowalewski, M.
2013-04-01
The cardiac resynchronization therapy is an effective treatment for systolic failure patients. Independent electrical stimulation of left and right ventricle corrects mechanical ventricular dyssynchrony. About 30-40% treated patients do not respond to therapy. In order to improve clinical outcome authors propose the two channels impedance cardiography for assessment of ventricular dyssynchrony. The proposed method is intended for validation of patients diagnosis and optimization of pacemaker settings for cardiac resynchronization therapy. The preliminary study has showed that bichannel impedance cardiography is a promising tool for assessment of ventricular dyssynchrony.
Andreas, Martin; Kuessel, Lorenz; Kastl, Stefan P; Wirth, Stefan; Gruber, Kathrin; Rhomberg, Franziska; Gomari-Grisar, Fatemeh A; Franz, Maximilian; Zeisler, Harald; Gottsauner-Wolf, Michael
2016-06-01
Pregnancy associated cardiovascular pathologies have a significant impact on outcome for mother and child. Bioimpedance cardiography may provide additional outcome-relevant information early in pregnancy and may also be used as a predictive instrument for pregnancy-associated diseases. We performed a prospective longitudinal cohort trial in an outpatient setting and included 242 pregnant women. Cardiac output and concomitant hemodynamic data were recorded from 11(th)-13(th) week of gestation every 5(th) week as well as at two occasions post partum employing bioimpedance cardiography. Cardiac output increased during pregnancy and peaked early in the third trimester. A higher heart rate and a decreased systemic vascular resistance were accountable for the observed changes. Women who had a pregnancy-associated disease during a previous pregnancy or developed hypertension or preeclampsia had a significantly increased cardiac output early in pregnancy. Furthermore, an effect of cardiac output on birthweight was found in healthy pregnancies and could be confirmed with multiple linear regression analysis. Cardiovascular adaptation during pregnancy is characterized by distinct pattern described herein. These may be altered in women at risk for preeclampsia or reduced birthweigth. The assessment of cardiac parameters by bioimpedance cardiography could be performed at low costs without additional risks.
Beyond auscultation: acoustic cardiography in clinical practice.
Wen, Yong-Na; Lee, Alex Pui-Wai; Fang, Fang; Jin, Chun-Na; Yu, Cheuk-Man
2014-04-01
Cardiac auscultation by stethoscope is widely used but limited by low sensitivity and accuracy. Phonocardiogram was developed in an attempt to provide quantitative and qualitative information of heart sounds and murmurs by transforming acoustic signal into visual wavelet. Although phonocardiogram provides objective heart sound information and holds diagnostic potentials of different heart problems, its examination procedure is time-consuming and it requires specially trained technicians to operate the device. Acoustic cardiography (AUDICOR, Inovise Medical, Inc., Portland, OR, USA) is a major recent advance in the evolution of cardiac auscultation technology. The technique is more efficient and less operator-dependent. It synchronizes cardiac auscultation with ECG recording and provides a comprehensive assessment of both mechanical and electronic function of the heart. The application of acoustic cardiography is far beyond auscultation only. It generates various parameters which have been proven to correlate with gold standards in heart failure diagnosis and ischemic heart disease detection. Its application can be extended to other diseases, including LV hypertrophy, constrictive pericarditis, sleep apnea and ventricular fibrillation. The newly developed ambulatory acoustic cardiography is potentially used in heart failure follow-up in both home and hospital setting. This review comprehensively summarizes acoustic cardiographic research, including the most recent development. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Muñoz, Jesús Escrivá; Gambús, Pedro; Jensen, Erik W; Vallverdú, Montserrat
2018-01-01
This works investigates the time-frequency content of impedance cardiography signals during a propofol-remifentanil anesthesia. In the last years, impedance cardiography (ICG) is a technique which has gained much attention. However, ICG signals need further investigation. Time-Frequency Distributions (TFDs) with 5 different kernels are used in order to analyze impedance cardiography signals (ICG) before the start of the anesthesia and after the loss of consciousness. In total, ICG signals from one hundred and thirty-one consecutive patients undergoing major surgery under general anesthesia were analyzed. Several features were extracted from the calculated TFDs in order to characterize the time-frequency content of the ICG signals. Differences between those features before and after the loss of consciousness were studied. The Extended Modified Beta Distribution (EMBD) was the kernel for which most features shows statistically significant changes between before and after the loss of consciousness. Among all analyzed features, those based on entropy showed a sensibility, specificity and area under the curve of the receiver operating characteristic above 60%. The anesthetic state of the patient is reflected on linear and non-linear features extracted from the TFDs of the ICG signals. Especially, the EMBD is a suitable kernel for the analysis of ICG signals and offers a great range of features which change according to the patient's anesthesia state in a statistically significant way. Schattauer GmbH.
Impedance cardiography: What is the source of the signal?
NASA Astrophysics Data System (ADS)
Patterson, R. P.
2010-04-01
Impedance cardiography continues to be investigated for various applications. Instruments for its use are available commercially. Almost all of the recent presentations and articles along with commercial advertisements have assumed that aortic volume pulsation is the source of the signal. A review of the literature will reveal that there is no clear evidence for this assumption. Starting with the first paper on impedance cardiography in 1964, which assumed the lung was the source of the signal, the presentation will review many studies in the 60's, 70's and 80's, which suggest the aorta and other vessels as well as atria and again the lung as possible sources. Current studies based on high resolution thoracic models will be presented that show the aorta as contributing only approximately 1% of the total impedance measurement, making it an unlikely candidate for the major contributor to the signal. Combining the results of past studies along with recent work based on models, suggest other vessels and regions as possible sources.
NASA Technical Reports Server (NTRS)
1996-01-01
Under contract to Johnson Space Center, the University of Minnesota developed the concept of impedance cardiography as an alternative to thermodilution to access astronaut heart function in flight. NASA then contracted Space Labs, Inc. to construct miniature space units based on this technology. Several companies then launched their own impedance cardiography, including Renaissance Technologies, which manufactures the IQ System. The IQ System is 5 to 17 times cheaper than thermodilution, and features the signal processing technology called TFD (Time Frequency Distribution). TFD provides three- dimensional distribution of the blood circulation force signals, allowing visualization of changes in power, frequency and time.
[Current status of noninvasive hemodynamics in hypertension].
Waisman, G
Hypertension is a haemodynamic disorder resulting from a persistent mismatch between cardiac output and peripheral resistance. Hypertension undergoes haemodynamic progression during its natural history. Impedance cardiography is a method of evaluating the cardiovascular system that obtains haemodynamic information from beat to beat through the analysis of variations in the impedance of the thorax on the passage of an electric current. Impedance cardiography unmasks the haemodynamic deterioration underlying the increase in blood pressure as age and systolic blood pressure increases. This method may help to improve blood pressure control through individualized treatment with reduction of peripheral resistance, maintenance of cardiac output or its increase, improvement of arterial compliance and preservation of organ-tissue perfusion. It is useful in the management of patients with resistant hypertension, since a greater percentage of patients controlled with changes in the treatment in relation to the haemodynamic measurements are obtained. Impedance cardiography is important and has prognostic utility in relation to a haemodynamic deterioration pattern and increased cardiovascular events. Copyright © 2017 SEH-LELHA. Publicado por Elsevier España, S.L.U. All rights reserved.
The IMPACT shirt: textile integrated and portable impedance cardiography.
Ulbrich, Mark; Mühlsteff, Jens; Sipilä, Auli; Kamppi, Merja; Koskela, Anne; Myry, Manu; Wan, Tingting; Leonhardt, Steffen; Walter, Marian
2014-06-01
Measurement of hemodynamic parameters such as stroke volume (SV) via impedance cardiography (ICG) is an easy, non-invasive and inexpensive way to assess the health status of the heart. We present a possibility to use this technology for monitoring risk patients at home. The IMPACT Shirt (IMPedAnce Cardiography Textile) has been developed with integrated textile electrodes and textile wiring, as well as with portable miniaturized hardware. Several textile materials were characterized in vitro and in vivo to analyze their performance with regard to washability, and electrical characteristics such as skin-electrode impedance, capacitive coupling and subjective tactile feeling. The small lightweight hardware measures ECG and ICG continuously and transmits wireless data via Bluetooth to a mobile phone (Android) or PC for further analysis. A lithium polymer battery supplies the circuit and can be charged via a micro-USB. Results of a proof-of-concept trial show excellent agreement between SV assessed by a commercial device and the developed system. The IMPACT Shirt allows monitoring of SV and ECG on a daily basis at the patient's home.
Novel characterization method of impedance cardiography signals using time-frequency distributions.
Escrivá Muñoz, Jesús; Pan, Y; Ge, S; Jensen, E W; Vallverdú, M
2018-03-16
The purpose of this document is to describe a methodology to select the most adequate time-frequency distribution (TFD) kernel for the characterization of impedance cardiography signals (ICG). The predominant ICG beat was extracted from a patient and was synthetized using time-frequency variant Fourier approximations. These synthetized signals were used to optimize several TFD kernels according to a performance maximization. The optimized kernels were tested for noise resistance on a clinical database. The resulting optimized TFD kernels are presented with their performance calculated using newly proposed methods. The procedure explained in this work showcases a new method to select an appropriate kernel for ICG signals and compares the performance of different time-frequency kernels found in the literature for the case of ICG signals. We conclude that, for ICG signals, the performance (P) of the spectrogram with either Hanning or Hamming windows (P = 0.780) and the extended modified beta distribution (P = 0.765) provided similar results, higher than the rest of analyzed kernels. Graphical abstract Flowchart for the optimization of time-frequency distribution kernels for impedance cardiography signals.
Legendre, Antoine; Bonnet, D; Bosquet, L
2018-01-01
Global ventricular response to exercise may be useful in follow-up of patients with residual right outflow tract lesions after congenital heart disease repair. In this context, impedance cardiography is considered accurate for stroke volume (SV) measurement during exercise testing, however, to date, only partial assessment of its reliability has been reported. We retrospectively evaluated relative and absolute reliability of peak SV by impedance cardiography during exercise using intraclass correlation (ICC) and standard error of measurement (SEM) in this population. Peak SV was measured in 30 young patients (mean age 14.4 years ± 2.1) with right ventricular outflow tract reconstruction who underwent two cardiopulmonary exercise tests at a mean one-year interval. SV was measured using a signal morphology impedance cardiography analysis device (PhysioFlow ® ) and was indexed to body surface area. ICC of peak indexed SV measurement was 0.80 and SEM was 10.5%. High heterogeneity was seen when comparing patients according to peak indexed SV; in patients with peak SV < 50 ml/m 2 (15 patients), ICC rose to 0.95 and SEM dropped to 2.7%, while in patients with a peak SV > 50 ml/m 2 relative and absolute reliability decreased (ICC = 0.45, SEM = 12.2%). Peak exercise SV assessment by a PhysioFlow ® device represents a highly reliable method in patients with residual right outflow tract lesions after congenital heart disease repair, especially in patients with peak SV < 50 ml/m 2 . In this latter group, a peak SV decrease > 7.3% (corresponding to the minimum "true" difference) should be considered a clinically-relevant decrease in global ventricular performance and taken into account when deciding whether to perform residual lesion removal.
Panfili, G; Piccini, L; Maggi, L; Parini, S; Andreoni, G
2006-01-01
In this study we explored the possibility to realize a low power device for Cardiac Output continuous monitoring based on impedance cardiography technique. We assessed the possibility to develop a system able to record data allow an intra-subjective analysis based on the daily variations of this measure. The device was able to acquire and to send signals using a wireless Bluetooth transmission. The electronic circuit was designed in order to minimize power consumption, dimension and weight. The reported results were interesting for what concerns the power consumption and then noise level. In this way was obtained a wearable device that will permit to define specific clinical protocols based on continuous monitoring of the Cardiac Output signal.
Cardiac output and cardiac contractility by impedance cardiography during exercise of runners
NASA Technical Reports Server (NTRS)
Kubicek, W. G.; Tracy, R. A.
1994-01-01
Most of the solid state electronic engineering of the system now generally known as the Minnesota Impedance Cardiograph was performed with the support of a five-year contract, NAS9-4500, with the NASA Lyndon B. Johnson Space Center, Houston, Texas. This contract ran from 1965 to 1970. In addition to the engineering design and development of the hardware, the contract called for testing on both animals and human subjects. This project also provided funds to construct twenty impedance cardiographs and place them in selected research and clinical facilities for further evaluation. This, then, led to the First Symposium on Impedance Cardiography, held at the NASA Lyndon B. Johnson Space Center, Houston, Texas, 2-4 June 1969. Twenty-four excellent papers were presented.
Wavelet analysis of the impedance cardiogram waveforms
NASA Astrophysics Data System (ADS)
Podtaev, S.; Stepanov, R.; Dumler, A.; Chugainov, S.; Tziberkin, K.
2012-12-01
Impedance cardiography has been used for diagnosing atrial and ventricular dysfunctions, valve disorders, aortic stenosis, and vascular diseases. Almost all the applications of impedance cardiography require determination of some of the characteristic points of the ICG waveform. The ICG waveform has a set of characteristic points known as A, B, E ((dZ/dt)max) X, Y, O and Z. These points are related to distinct physiological events in the cardiac cycle. Objective of this work is an approbation of a new method of processing and interpretation of the impedance cardiogram waveforms using wavelet analysis. A method of computer thoracic tetrapolar polyrheocardiography is used for hemodynamic registrations. Use of original wavelet differentiation algorithm allows combining filtration and calculation of the derivatives of rheocardiogram. The proposed approach can be used in clinical practice for early diagnostics of cardiovascular system remodelling in the course of different pathologies.
DeMarzo, Arthur P
2018-06-01
New guidelines on hypertension eliminated the classification of prehypertension and divided those blood pressure (BP) levels into elevated BP and stage 1 hypertension. For elevated BP, this study showed that cardiovascular (CV) abnormalities were prevalent in adults over 40 years of age with at least 2 CV risk factors. Detecting abnormalities of the CV system moves a patient from being at high risk to having earlystage cardiovascular disease (CVD) and supports a decision to treat. By redefining stage 1 and lowering the target BP, the new guidelines have set an ambitious goal for early intervention to prevent progression of CVD. Proper drug selection and titration are critical. Hypertensive patients have diverse CV abnormalities that can be quantified by impedance cardiography. By stratifying patients with ventricular, vascular, and hemodynamic abnormalities, treatment can be customized based on the abnormal underlying mechanisms to rapidly control BP and prevent progression of CVD.
Petersen, John W; Liu, Jing; Chi, Yueh-Yun; Lingis, Melissa; Williams, R Stan; Rhoton-Vlasak, Alice; Segal, Mark S; Conrad, Kirk P
2017-04-01
Various non-invasive methods are available to measure cardiac output (CO) during pregnancy. We compared serial measures of CO using various methods to determine which provided the least variability. Ten patients with spontaneous pregnancy had estimation of CO at baseline prior to becoming pregnant and at the end of the first and third trimesters. Echocardiographic data were used to estimate CO using the Teichholz method, Simpson's biplane method, and the Doppler determined velocity time integral (VTI) method. In addition, a Bioz Dx device was used to estimate CO by impedance cardiography. CO estimated with the VTI method had the lowest beat-to-beat variability. CO estimated with the VTI method was higher than CO estimated with the 2D-Teichholz method and Simpson's method. The percent change in CO during pregnancy was similar for all echo methods (VTI, Teichholz, and Simpson's biplane). Baseline CO determined with impedance cardiography was higher than CO determined with the VTI method. However, change in CO during pregnancy was significantly lower when measured with impedance cardiography. There was marked heterogeneity in the degree of rise in CO during the first trimester (-3 to 55%). The wide variation in the gestational rise in CO was unexpected, and at least in part secondary to variable increase in heart rate. We recommend the use of the Doppler determined VTI method for the estimation of CO in pregnancy. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.
NASA Technical Reports Server (NTRS)
Cowings, Patricia S.; Naifeh, Karen; Thrasher, Chet
1988-01-01
This report contains the source code and documentation for a computer program used to process impedance cardiography data. The cardiodynamic measures derived from impedance cardiography are ventricular stroke column, cardiac output, cardiac index and Heather index. The program digitizes data collected from the Minnesota Impedance Cardiograph, Electrocardiography (ECG), and respiratory cycles and then stores these data on hard disk. It computes the cardiodynamic functions using interactive graphics and stores the means and standard deviations of each 15-sec data epoch on floppy disk. This software was designed on a Digital PRO380 microcomputer and used version 2.0 of P/OS, with (minimally) a 4-channel 16-bit analog/digital (A/D) converter. Applications software is written in FORTRAN 77, and uses Digital's Pro-Tool Kit Real Time Interface Library, CORE Graphic Library, and laboratory routines. Source code can be readily modified to accommodate alternative detection, A/D conversion and interactive graphics. The object code utilizing overlays and multitasking has a maximum of 50 Kbytes.
Borodiciene, Jurgita; Gudaityte, Jurate; Macas, Andrius
2015-05-06
Although the prone position providing better exposure for anorectal surgery is required it can cause a reduction of cardiac output and cardiac index. The goal was to compare haemodynamic changes assessed by impedance cardiography during anorectal surgery under low-dose spinal anaesthesia in lithotomy and jack-knife position. The prospective randomized controlled study included 104, ASA I-II adult patients admitted for elective minor anorectal surgery, assigned to be performed in lithotomy (groupL, n = 52) or jack-knife position (groupJ, n = 52). After arrival to operating room the standard monitoring, impedance cardiography device was connected to the patient, and the following variables were recorded: cardiac output, cardiac index, systemic vascular resistance, stroke index at times of arrival to operating room, placement for, start and end of surgery and placement to bed. Spinal block was made in the sitting position with 4 mg of 0.5% hyperbaric bupivacaine and 10 μg of Fentanyl injected over 2 min. Comparison was based on haemodynamic changes between and inside groups over time. Student's t, chi square tests were used for statistical analysis with p < 0.05 regarded as statistically significant. The reduction of cardiac output was statistically significant after placement of the patient into the prone position: from baseline 7.4+/-1.6 to 4.9+/-1.2 after placement for and 4.7+/-1.2 at the start and end of surgery (mean +/-SD l/min). The difference of cardiac output between groups was 2.0 l/min after positioning for and the start of surgery and 1.5 l/min at the end of surgery (p < 0.05). Mean cardiac index reduced from baseline 3.9+/-0.8 to 2.6+/-0.7 and 2.4+/-0.6 (mean+/-SD l/min/m(2)) in groupJ and between groups: by 1.0 l/min/m(2) after placement for, 1.1 at the start and 0.8 at the end of surgery (p < 0.05). Systemic vascular resistance increased from baseline 1080+/-338 to 1483+/-479 after placement for, 1523+/-481 at the start and 1525+/-545 at the end of surgery in groupJ (mean+/-SD dynes/sec/cm(-5), p < 0.05). According to impedance cardiography, jack-knife position after low-dose spinal anaesthesia produces transitory, but statistically significant reduction of cardiac output and cardiac index with increase of systemic vascular resistance, compared to insignificant changes in lithotomy position. Clinical Trials NCT02115178.
A portable device to assess underwater changes of cardio dynamic variables by impedance cardiography
NASA Astrophysics Data System (ADS)
Tocco, F.; Crisafulli, A.; Marongiu, E.; Milia, R.; Kalb, A.; Concu, A.
2012-12-01
Data concerning heart rate (HR), stroke volume (SV), and cardiac output (CO) during dynamic apnoea (DA) were collected from 10 healthy male, elite divers by means of an impedance cardiograph adapted to the underwater environment (C. O. Re., from 2C Technologies Inc, Italy). Three trials were performed by the divers in a 3-m-deep pool with a water temperature of 25°C: 3-minute head-out immersion during normal breathing (A), till exhaustion immersed at the surface (B) and at 3m depth (C). Both B and C conditions did not led to changes in HR, SV and CO compared to A. Data indicate that typical diving response consisting in a reduction of HR, SV and CO was not present during DA, probably due to sympathetic activation induced by exercise during DA, which partially obscured the effects of the diving response. Moreover, this study highlights the innovative role of our portable, impedance cardiography device, i.e. the C. O. Re., in easily assessing cardiodynamic changes in subjects engaged in exercise schedules including phases of underwater, dynamic apnoea.
Demarzo, Arthur P
2009-01-01
Early detection of cardiovascular disease (CVD) could initiate appropriate treatment and prevent progression. This study used impedance cardiography (ICG) waveform analysis with postural change to detect functional CVD in women older than 40 years with no history of CVD and >or=2 of the following risk factors: cigarette smoking, poor diet, physical inactivity, central adiposity, family history of premature CVD, hypertension, and dyslipidemia. A study group of 32 women underwent ICG in standing and supine positions. An age-matched control group had 20 women with an active lifestyle, no risk factors, and no history of CVD. All women in the control group had normal ICG data. All women in the study group had some abnormal ICG data, with 28 (87.5%) having multiple ICG abnormalities. ICG data indicated that 13 (40.6%) had ventricular dysfunction, 14 (43.8%) had high vascular resistive load, and 30 (93.8%) had elevated vascular pulsatile load. The data suggest that subclinical CVD, detectable by ICG, is prevalent in women older than 40 years with multiple risk factors. Abnormal ICG results could expedite the initiation of customized treatment as part of a preventive approach to CVD. (c) 2009 Wiley Periodicals, Inc.
DeMarzo, Arthur P; Kelly, Russell F; Calvin, James E
2007-01-01
Early detection of asymptomatic left ventricular systolic dysfunction (LVSD) is beneficial in managing heart failure. Recent studies have cast doubt on the usefulness of cardiac output as an indicator of LVSD. In impedance cardiography (ICG), the dZ/dt waveform has a systolic wave called the E wave. This study looked at measurements of the amplitude and area of the E wave compared with ICG-derived cardiac output, stroke volume, cardiac index, and stroke index as methods of assessing LVSD. ICG data were obtained from patients (n=26) admitted to a coronary care unit. Clinical LVSD severity was stratified into 4 groups (none, mild, moderate, and severe) based on echocardiography data and standard clinical assessment by a cardiologist blinded to ICG data. Statistical analysis showed that the E wave amplitude and area were better indicators of the level of LVSD than cardiac output, stroke volume, cardiac index, or stroke index. ICG waveform analysis has potential as a simple point-of-care test for detecting LVSD in asymptomatic patients at high risk for developing heart failure and for monitoring LVSD in patients being treated for heart failure.
Air Saturation Dive 4 - 8 February 1980, CEDD Test Number 1-80.
1980-09-01
heart rate. Blood pressure measurements will be recorded. A finger-prick blood sample will be required from each subject for microhematocrit...manoeuvres on command from the surface. Termination Criteria. With the exception of the finger-prick blood sample for microhematocrit determination, all...each experimental period. 3. Scissors, alligator clips - 4 clips/subject. 4. Metric steel tape measure. 5. Impedance cardiography connecting cables - I
DeMarzo, Arthur P; Calvin, James E; Kelly, Russell F; Stamos, Thomas D
2005-01-01
For the diagnosis and management of heart failure, it would be useful to have a simple point-of-care test for assessing ventricular function that could be performed by a nurse. An impedance cardiography (ICG) parameter called systolic amplitude (SA) can serve as an indicator of left ventricular systolic function (LVSF). This study tested the hypothesis that patients with normal LVSF should have a significant increase in SA in response to an increase in end-diastolic volume caused by postural change from sitting upright to supine, while patients with depressed LVSF associated with heart failure should have a minimal increase or a decrease in SA from upright to supine. ICG data were obtained in 12 patients without heart disease and with normal LVSF and 18 patients with clinically diagnosed heart failure. Consistent with the hypothesis, patients with normal LVSF had a significant increase in SA from upright to supine, whereas heart failure patients had a minimal increase or a decrease in SA from upright to supine. This ICG procedure may be useful for monitoring the trend of patient response to titration of beta blockers and other medications. ICG potentially could be used to detect worsening LVSF and provide a means of measurement for adjusting treatment.
Cardiovascular Imaging and Image Processing: Theory and Practice - 1975
NASA Technical Reports Server (NTRS)
Harrison, Donald C. (Editor); Sandler, Harold (Editor); Miller, Harry A. (Editor); Hood, Manley J. (Editor); Purser, Paul E. (Editor); Schmidt, Gene (Editor)
1975-01-01
Ultrasonography was examined in regard to the developmental highlights and present applicatons of cardiac ultrasound. Doppler ultrasonic techniques and the technology of miniature acoustic element arrays were reported. X-ray angiography was discussed with special considerations on quantitative three dimensional dynamic imaging of structure and function of the cardiopulmonary and circulatory systems in all regions of the body. Nuclear cardiography and scintigraphy, three--dimensional imaging of the myocardium with isotopes, and the commercialization of the echocardioscope were studied.
Hargens, Trent A; Aron, Adrian; Newsome, Laura J; Austin, Joseph L; Shafer, Brooke M
2015-01-01
Obstructive sleep apnea (OSA) is a prevalent form of sleep-disordered breathing. Evidence suggests that OSA may lead to cardiac remodeling, although the literature is equivocal. Previous literature suggests a high percentage of individuals entering a cardiac rehabilitation (CR) program also have OSA. The objective of this study was to determine whether resting hemodynamic variables were altered in OSA subjects entering CR compared with those without OSA, as determined by impedance cardiography. Subjects entering an early outpatient CR program were screened for OSA using an at-home screening device and verified by a sleep physician. Subjects were divided into an OSA group (n = 48) or a control group (n = 25) on the basis of the screening results. Hemodynamic variables were measured during supine rest using impedance cardiography. A 6-minute walk test was performed to assess functional capacity. The proportion of cardiac diagnoses was similar between groups. Overall, 66% of the subjects were positive for OSA. Subject groups did not differ by age, body mass index, heart rate, diastolic blood pressure, or functional capacity. Cardiac output, cardiac index, stroke volume, contractility index, and left cardiac work index were all significantly decreased in the OSA group compared with the control group (P < .05). Findings suggest that OSA results in decreased cardiac function in patients entering CR, likely because of pressure and volume changes associated with apneic events. This may place those individuals at a disadvantage in recovering from their cardiac event, and place them at increased risk for secondary complications.
Central Hemodynamics Measured During 5 Repetition Maximum Free Weight Resistance Exercise.
Howard, Jonathan S; McLester, Cherilyn N; Evans, Thomas W; McLester, John R; Calloway, Jimmy P
2018-01-01
The PhysioFlow™ is a piece of equipment that uses bioimpedance cardiography to measure central hemodynamics. The purpose of this research was to explore the novel approach of monitoring central hemodynamics during free weight resistance exercise using bioimpedance cardiography throughout a 5 repetition maximum (5RM). Thirty participants ranging from beginner to advanced lifters (16 males and 14 females) completed a 5RM for back squat, seated push press, and bicep curl while connected to the PhysioFlow™ to assess the response of heart rate (HR), stroke volume (SV), cardiac output (Q), and ejection fraction (EF). Participants were cued for form and to breathe normally throughout the lifts. The PhysioFlow™ detected an increase in HR and Q for all lifts between rest and each repetition ( p < 0.05). There was also an increase in HR and Q from repetition 1 to repetition 5 for all lifts ( p < 0.05). No changes in EF or SV were detected between resting measurements and each repetition for all lifts ( p > 0.05) and no changes in EF or SV were detected when all repetitions were compared to each other for all lifts ( p > 0.05). In conclusion, the PhysioFlow™ was able to detect changes in HR and Q during dynamic free weight resistance exercise. This novel approach may provide a mechanism for monitoring central hemodynamics during free weight resistance training. However, more research needs to be conducted as the exercise protocol for this investigation did not allow for a comparison to a reference method.
DeMarzo, Arthur P
2013-06-01
Early detection of cardiovascular disease (CVD) in prehypertension could initiate appropriate treatment and prevent progression. Impedance cardiography (ICG) is a noninvasive technology that can be used to assess cardiovascular function. This study used ICG waveform analysis with postural change to detect CVD in asymptomatic prehypertensive adults over 40 years of age with no history of CVD and at least 2 cardiovascular risk factors: cigarette smoking, poor diet, physical inactivity, central obesity, family history of premature CVD, elevated blood glucose, and dyslipidemia. A study group of 25 apparently healthy adults was tested by ICG in standing and supine positions. Criteria for an age-matched control group of 16 healthy subjects included an active lifestyle, no risk factor, and no history of CVD. In addition to hemodynamic measurements of systemic vascular resistance (SVR) and cardiac index (CI), ICG used SVR to assess vascular resistive load, an index of arterial compliance and a widening of the systolic waveform to assess vascular pulsatile load, and waveform analysis and measured wave amplitude to detect ventricular dysfunction. All subjects in the study group had some abnormal ICG data, with an average of 2.9 ± 1.5 abnormalities per person. ICG indicated that 24 (96%) had elevated vascular load, 13 (52%) had some type of ventricular dysfunction, and 12 (48%) had abnormal hemodynamics. For the control group, ICG showed none (0%) with elevated vascular load, none (0%) with ventricular dysfunction, and 7 (44%) with high CI. Prehypertensives over 40 years of age with multiple risk factors have different cardiovascular abnormalities. This ICG test could be used as part of a prevention program for early detection of CVD. An abnormal ICG test could expedite the initiation of customized treatment that targets the subclinical CVD.
Digoxin and bepridil: pharmacokinetic and pharmacodynamic interactions.
Belz, G G; Wistuba, S; Matthews, J H
1986-01-01
The influence of bepridil on steady-state serum digoxin concentrations (SDCs) and the pharmacodynamic actions of both drugs were tested in 48 healthy subjects in a randomized, double-blind study. Subjects were assigned to one of two groups of 24 subjects each: One group received placebo 1, while the other received digoxin, 0.375 mg/day, loaded with doubled doses on days 1 and 2, for 14 days. After 7 days the groups were subdivided into four groups of 12 subjects each and received concurrent dosing of digoxin with either placebo 2 or bepridil, 300 mg/day, loaded with 900 mg on day 8. Mean (+/- SD) SDCs rose during concurrent bepridil dosing from 0.93 +/- 0.22 to 1.25 +/- 0.25 ng/ml (P less than 0.001). Noninvasive cardiovascular parameters from ECG, systolic time intervals, and electrical impedance cardiography were not influenced by the placebos. Digoxin and bepridil reduced heart rate and prolonged the PQ interval because of negative chronotropic and dromotropic properties. Positive inotropism from digoxin shortened the corrected electromechanical systole (QS2c) and the preejection period and increased impedance cardiography [(dZ/dt)/RZ index]; the opposite effects occurred after bepridil, indicating negative inotropism. The QT interval corrected for heart rate (QTc) showed a similar pattern of changes, as did QS2c for each drug. Concurrent dosing of both drugs resulted in an addition of their chronotropic effects, whereas the dromotropic effects of each drug alone was not intensified. The strengthened digoxin effect from the increased SDC diminished the negative inotropic effect of bepridil. Overall, drug coadministration resulted in a nearly unchanged digoxin-induced positive inotropism.(ABSTRACT TRUNCATED AT 250 WORDS)
Guerra, Stefania; Boscari, Federico; Avogaro, Angelo; Di Camillo, Barbara; Sparacino, Giovanni; de Kreutzenberg, Saula Vigili
2011-08-01
The metabolic syndrome (MS), a predisposing condition for cardiovascular disease, presents disturbances in hemodynamics; impedance cardiography (ICG) can assess these alterations. In subjects with MS, the morphology of the pulses present in the ICG time series is more irregular/complex than in normal subjects. Therefore, the aim of the present study was to quantitatively assess the complexity of ICG times series in 53 patients, with or without MS, through a nonlinear analysis algorithm, the approximate entropy, a method employed in recent years for the study of several biological signals, which provides a scalar index, ApEn. We correlated ApEn computed from ICG times series data during fasting and postprandial phase with the presence of alterations in the parameters defining MS [Adult Treatment Panel (ATP) III (Grundy SM, Brewer HB Jr, Cleeman JI, Smith SC Jr, Lenfant C; National Heart, Lung, and Blood Institute; American Heart Association. Circulation 109: 433-438, 2004) and the International Diabetes Federation (IDF) definition]. Results show that ApEn was significantly higher in subjects with MS compared with those without (1.81 ± 0.09 vs. 1.65 ± 0.13; means ± SD; P = 0.0013, with ATP III definition; 1.82 ± 0.09 vs. 1.67 ± 0.12; P = 0.00006, with the IDF definition). We also demonstrated that ApEn increase parallels the number of components of MS. ApEn was then correlated to each MS component: mean ApEn values of subjects belonging to the first and fourth quartiles of the distribution of MS parameters were statistically different for all parameters but HDL cholesterol. No difference was observed between ApEn values evaluated in fasting and postprandial states. In conclusion, we identified that MS is characterized by an increased complexity of ICG signals: this may have a prognostic relevance in subjects with this condition.
Ziegeler, Stephan; Grundmann, Ulrich; Fuerst, Oliver; Raddatz, Alexander; Kreuer, Sascha
2007-02-01
Impedance Cardiography (ICG) has been shown to be a feasible and accurate method for non-invasive measurement of cardiac index (CI). Aim of this investigation was the correlation of hemodynamic variables under exercise as measured by a specific ICG-monitor (Solar IKG-Modul, Version 3.0, GE-Healthcare, Freiburg, Germany) with metabolic variables. Ten healthy volunteers were included in the investigation doing ergometer exercise (5 min equilibration followed by 5 min each at 50, 75, 100 and 125 W). Hemodynamic parameters were obtained by ICG. Metabolic variables were assessed by indirect calorimetry with the Deltatrac II Metabolic monitor using a helmet system for spontaneous respiration. CI increased throughout exercise (baseline: 3.0 +/- 0.4 l/min/m(2); 125 W: 4.8 +/- 0.5 l/min/m(2)). Heart rate (baseline: 87.2 +/- 13.4 bpm; 125 W: 152.7 +/- 22.4 bpm) and contractility (velocity index) (baseline: 48.9 +/- 9.3/1000 s; 125 W: 70.5 +/- 10.0/1000 s) showed a continuous rise while the stroke index decreased after an initial rise (baseline: 35.0 +/- 4.6 ml/m(2); 50 W: 37.6 +/- 4.9 ml/m(2); 75 W: 41.2 +/- 5.9 ml/m(2); 125 W: 32.3 +/- 6.1 ml/m(2)). VO(2) (baseline: 335.2 +/- 84.1 ml/min; 125 W: 1298.9 +/- 282.3 ml/min) and VCO(2)(baseline: 255.4 +/- 74.5 ml/min; 125 W: 1342.5 +/- 282.5 ml/min) increased throughout exercise. There was a good correlation in the individual fits between hemodynamic and metabolic variables. CI in healthy volunteers, as measured by the Solar IKG-Modul, correlates well with O(2)-consumption and CO(2)-production in individual subjects, thus indicating the metabolic needs under exercise conditions in healthy individuals.
NASA Technical Reports Server (NTRS)
Harrison, D. C.; Kates, R.
1982-01-01
The effect of bed rest on drug disposition and physiological function was investigated as part of a project to determine the cardiovascular effects of space flight. One group of subjects was given doses of lidocane, penicillin-G, and ICG during a control period and following seven days of bed rest. Cardiac function was evaluated by echo-cardiography. Renal function was evaluated in a second group before and after several days of bed rest. Inulin, para-aminohippurate, and dextran clearances were studied. In the first group, the post-bed rest parameters were not statistically different from the pre-bed rest valves. In the second study, renal function did not change significantly after seven days of bed rest. Plans for future research are reviewed.
Murata, Makoto; Adachi, Hitoshi; Oshima, Shigeru; Kurabayashi, Masahiko
2017-01-01
In a given individual, a consistent relationship exists between oxygen uptake (V˙O 2 ) and heart rate (HR) during exercise. The quotient of V˙O 2 and HR (V˙O 2 /HR) is called the oxygen pulse (O 2 pulse), and its value is dependent on stroke volume (SV). However, it is difficult to believe that the O 2 pulse would indicate the SV when HR has been modified as with the use of beta-adrenergic receptor blockers (BB). Until now, the effect of BB on peak O 2 pulse has not been precisely studied. We tried to clarify the effect of BB on the relationship between O 2 pulse and SV. Of 699 consecutive heart disease subjects who performed cardiopulmonary exercise tests (CPX) from 2012 to 2014, we enrolled 430 subjects who had sinus rhythm and could perform CPX until exhaustion. One hundred and fifty-seven subjects were taking BB. SV was evaluated during CPX using impedance cardiography, and we compared the peak O 2 pulse with peak SV between patients without BB (Group A) and with BB (Group B). The HRs at rest and peak exercise in Group A were greater than those in Group B (74.4±13.0/min vs. 71.8±11.3/min, p<0.01, 134.9±21.7/min vs. 124.9±23.6/min, p<0.01, respectively). The regression line of the peak O 2 pulse against the peak SV was steeper in Group B than in Group A. When we divided the patients into two groups according to the average values of the peak SV and peak V˙O 2 , O 2 pulse/SV ratio in Group B above the average was greater than that in Group A, whereas it was similar in the two groups that were below average. We found that the increase in the O 2 pulse was disproportionately greater than the SV that was measured by impedance cardiography when a BB was used in patients with preserved SV and exercise tolerance. Copyright © 2016. Published by Elsevier Ltd.
Decoding carotid pressure waveforms recorded by laser Doppler vibrometry: Effects of rebreathing
NASA Astrophysics Data System (ADS)
Casaccia, Sara; Sirevaag, Erik J.; Richter, Edward; O'Sullivan, Joseph A.; Scalise, Lorenzo; Rohrbaugh, John W.
2014-05-01
The principal goal of this study was to assess the capability of the laser Doppler vibrometry (LDV) method for assessing cardiovascular activity. A rebreathing task was used to provoke changes within individuals in cardiac and vascular performance. The rebreathing task is known to produce multiple effects, associated with changes in autonomic drive as well as alterations in blood gases. The rise in CO2 (hypercapnia), in particular, produces changes in the cerebral and systemic circulation. The results from a rebreathing task (involving rebreathing the same air in a rubber bag) are presented for 35 individuals. The LDV pulse was measured from a site overlying the carotid artery. For comparison and validation purposes, several conventional measures of cardiovascular function were also obtained, with an emphasis on the electrocardiogram (ECG), continuous blood pressure (BP) from the radial artery, and measures of myocardial performance using impedance cardiography (ICG). During periods of active rebreathing, ventilation increased. The conventional cardiovascular effects included increased mean arterial BP and systemic vascular resistance, and decreased cardiac stroke volume (SV) and pulse transit time (PTT). These effects were consistent with a pattern of α-adrenergic stimulation. During the immediate post-rebreathing segments, in contrast, mean BP was largely unaffected but pulse BP increased, as did PTT and SV, whereas systemic vascular resistance decreased-a pattern consistent with β-adrenergic effects in combination with the direct effects of hypercapnia on the vascular system. Measures of cardiovascular activity derived from the LDV pulse velocity and displacement waveforms revealed patterns of changes that mirrored the results obtained using conventional measures. In particular, the ratio of the maximum early peak in the LDV velocity pulse to the maximum amplitude of the LDV displacement pulse (in an early systolic interval) closely mirrored the conventional SV effects. Additionally, changes in an augmentation ratio (computed as the maximum amplitude of the LDV displacement pulse during systole / amplitude at the end of the incident wave) were very similar to changes in systemic vascular resistance. Heart rates measured from the ECG and LDV were nearly identical. These preliminary results suggest that measures derived using the non-contact LDV technique can provide surrogate measures for those obtained using impedance cardiography.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Savukov, Igor Mykhaylovich; Boshier, Malcolm Geoffrey
Atomic magnetometers (AM) are finding many applications in biomagnetism, national security, industry, and science. Fiber-coupled (FC) designs promise to make them compact and flexible for operation. Most FC designs are based on a single-beam configuration or electrical heating. Here, we demonstrate a two-beam FC AM with laser heating that has 5 fT/Hz 1/2 sensitivity at low frequency (50 Hz), which is higher than that of other fiber-coupled magnetometers and can be improved to the sub-femtotesla level. Here, this magnetometer is widely tunable from DC to very high frequencies (as high as 100 MHz; the only issue might be the applicationmore » of a suitable uniform and stable bias field) with a sensitivity under 10 fT/Hz 1/2 and can be used for magneto-encephalography (MEG), magneto-cardiography (MCG), underground communication, ultra-low MRI/NMR, NQR detection, and other applications.« less
A high-sensitivity tunable two-beam fiber-coupled high-density magnetometer with laser heating
Savukov, Igor Mykhaylovich; Boshier, Malcolm Geoffrey
2016-10-13
Atomic magnetometers (AM) are finding many applications in biomagnetism, national security, industry, and science. Fiber-coupled (FC) designs promise to make them compact and flexible for operation. Most FC designs are based on a single-beam configuration or electrical heating. Here, we demonstrate a two-beam FC AM with laser heating that has 5 fT/Hz 1/2 sensitivity at low frequency (50 Hz), which is higher than that of other fiber-coupled magnetometers and can be improved to the sub-femtotesla level. Here, this magnetometer is widely tunable from DC to very high frequencies (as high as 100 MHz; the only issue might be the applicationmore » of a suitable uniform and stable bias field) with a sensitivity under 10 fT/Hz 1/2 and can be used for magneto-encephalography (MEG), magneto-cardiography (MCG), underground communication, ultra-low MRI/NMR, NQR detection, and other applications.« less
New diagnostic modalities in the diagnosis of heart failure.
Mitchell, Judith E.; Palta, Sanjeev
2004-01-01
Heart failure (HF) is the one cardiovascular disease that is increasing in prevalence in the United States. As the population continues to age, the incidence will certainly be amplified. However, some studies have shown that HF is correctly diagnosed initially in only 50% of affected patients. Despite the use of history, physical examination, echocardiogram, and chest x-ray, the percentage of correct initial diagnosis of HF is low. Recognizing the symptoms of HF decompensations is often problematic because other diagnoses can mimic them. There are two new diagnostic modalities that offer promise in improving HF diagnostic accuracy and identifying early HF decompensations. These diagnostic modalities include tests utilizing impedance cardiography and the B-type natriuretic peptide assay. They have the potential of increasing the accuracy of HF diagnosis and guide pharmacological treatment in the inpatient and outpatient settings. They may also assist in the recognition (or prediction) of acute HF decompensations. Images Figure 2 PMID:15586645
Cardiovascular dynamics during the initial period of head-down tilt
NASA Technical Reports Server (NTRS)
Tomaselli, Clare Marie; Kenney, Richard A.; Frey, Mary Anne Bassett; Hoffler, G. Wyckliffe
1987-01-01
The cardiovascular response to 1 h of 60-deg head-down tilt was studied in 12 male subjects, ages 30-39 years, to simulate the early effects of weightlessness. Fluid shifts, hemodynamic variables, and indices of myocardial contractility were evaluated by utilizing electrocardiography, systolic time intervals, impedance cardiography, sphygmomanometry, and measurement of calf circumference. Most cardiovascular variables remained stable throughout the initial 30 min of the protocol, even though translocation of fluid from the legs to the thorax commenced immediately with the onset of head-down tilt. In contrast, minutes 30-60 were characterized by reduced stroke volume, cardiac output, mean stroke ejection rate, and Heather index concomitant with an elevation in mean arterial pressure. Intrathoracic fluid volume continued to increase, while leg volume continued to decrease. This latter physiological response suggests intrathoracic sequestration of fluid volume; blood was apparently redistributed to the pulmonary circulation rather than being retained in the great veins.
Effect of a central redistribution of fluid volume on response to lower-body negative pressure
NASA Technical Reports Server (NTRS)
Tomaselli, Clare M.; Frey, Mary A. B.; Kenney, Richard A.; Hoffler, G. Wyckliffe
1990-01-01
Cardiovascular responses to lower-body negative pressure (LBNP) were studied following 1 hour of 6-deg head-down tilt to determine whether a redistribution of blood volume toward the central circulation modifies the subsequent response to orthostatic stress. Responses of 12 men, ages 30-39 years, were evaluated by electrocardiography, impedance cardiography, sphygmomanometry, and measurement of calf circumference. During the LBNP that followed head-down tilt, as compared with control LBNP (no preceding head-down tilt) subjects, had smaller stroke volume and cardiac output, greater total peripheral resistance, and less calf enlargement. These differences reflect differences in the variables immediately preceding LBNP. Magnitudes of the responses from pre-LBNP to each pressure stage of the LBNP procedure did not differ between protocols. Mean and diastolic arterial pressures were slightly elevated after LBNP-control, but they fell slightly during LBNP post-tilt.
Silvia, Paul J; Beaty, Roger E; Nusbaum, Emily C; Eddington, Kari M; Kwapil, Thomas R
2014-10-01
Executive approaches to creativity emphasize that generating creative ideas can be hard and requires mental effort. Few studies, however, have examined effort-related physiological activity during creativity tasks. Using motivational intensity theory as a framework, we examined predictors of effort-related cardiac activity during a creative challenge. A sample of 111 adults completed a divergent thinking task. Sympathetic (PEP and RZ) and parasympathetic (RSA and RMSSD) outcomes were assessed using impedance cardiography. As predicted, people with high creative achievement (measured with the Creative Achievement Questionnaire) showed significantly greater increases in sympathetic activity from baseline to task, reflecting higher effort. People with more creative achievements generated ideas that were significantly more creative, and creative performance correlated marginally with PEP and RZ. The results support the view that creative thought can be a mental challenge. Copyright © 2014 Elsevier B.V. All rights reserved.
A High-Sensitivity Tunable Two-Beam Fiber-Coupled High-Density Magnetometer with Laser Heating
Savukov, Igor; Boshier, Malcolm G.
2016-01-01
Atomic magnetometers (AM) are finding many applications in biomagnetism, national security, industry, and science. Fiber-coupled (FC) designs promise to make them compact and flexible for operation. Most FC designs are based on a single-beam configuration or electrical heating. Here, we demonstrate a two-beam FC AM with laser heating that has 5 fT/Hz1/2 sensitivity at low frequency (50 Hz), which is higher than that of other fiber-coupled magnetometers and can be improved to the sub-femtotesla level. This magnetometer is widely tunable from DC to very high frequencies (as high as 100 MHz; the only issue might be the application of a suitable uniform and stable bias field) with a sensitivity under 10 fT/Hz1/2 and can be used for magneto-encephalography (MEG), magneto-cardiography (MCG), underground communication, ultra-low MRI/NMR, NQR detection, and other applications. PMID:27754358
Wearable Sensing of Cardiac Timing Intervals from Cardiogenic Limb Vibration Signals
Wiens, Andrew D.; Johnson, Ann; Inan, Omer T.
2017-01-01
In this paper we describe a new method to measure aortic valve opening (AVO) and closing (AVC) from cardiogenic limb vibrations (i.e., wearable ballistocardiogram [BCG] signals). AVO and AVC were detected for each heartbeat with accelerometers on the upper arm (A), wrist (W), and knee (K) of 22 subjects following isometric exercise. Exercise-induced changes were recorded with impedance cardiography. The method, Filter BCG, detects peaks in distal vibrations after filtering with individually-tuned bandpass filters. In agreement with recent studies, we did not find peaks at AVO and AVC in limb vibrations directly. Interestingly, distal vibrations filtered with FilterBCG yielded reliable peaks at AVO (r2 = 0.95 A, 0.94 W, 0.77 K) and AVC (r2= 0.92 A, 0.89 W, 0.68 K). FilterBCG measures AVO and AVC accurately from arm, wrist, and knee vibrations, and it outperforms the standard R-J interval method. PMID:29123459
Development of improved superconductive axial gradiometers for biomagnetic SQUID applications
NASA Astrophysics Data System (ADS)
Budnyk, M. M.; Minov, Yu. D.; Lyakhno, V. Yu.; Desnenko, V. A.; Linnik, A. S.; Shopen, O. B.
2018-03-01
SQUID magnetometers for biomagnetic measurements are equipped with superconductive gradiometers which are required to provide a high signal-to-noise ratio at low frequencies, sufficient mechanical strength and sustained performance under repeated thermal cycles, as well as a low level of intrinsic magnetic noise. This paper describes the design of a gradiometer made with a carbon-fiber reinforced composite material for magnetic cardiography measurements. The thermal coefficient of linear expansion (TCLE) of the carbon fiber composite can be precisely adjusted to match that of the superconducting detector coil wire. This is achieved thanks to the difference in the TCLE of carbon fibers in the longitudinal and transverse directions and is realized by varying the laying directions of the fiber in the composite. The data of magnetic susceptibility measurements on carbon fiber composite are reported, showing the magnetic susceptibility about six times smaller than that of graphite. The presented gradiometer design provides a high degree of balancing and is patented along side other specific techniques.
Sack, Martin; Lempa, Wolfgang; Steinmetz, Adrian; Lamprecht, Friedhelm; Hofmann, Arne
2008-10-01
EMDR combines stimuli that evoke divided attention--e.g. eye movements--with exposure to traumatic memories. Our objective was to investigate psycho-physiological correlates of EMDR during treatment sessions. A total of 55 treatment sessions from 10 patients with PTSD was monitored applying impedance cardiography. Onset of every stimulation/exposure period (n=811) was marked and effects within and across stimulation sets on heart rate (HR), heart rate variability (HRV), pre-ejection period (PEP) and respiration rate were examined. At stimulation onsets a sharp increase of HRV and a significant decrease of HR was noticed indicating de-arousal. During ongoing stimulation, PEP and HRV decreased significantly while respiration rate significantly increased, indicating stress-related arousal. However, across entire sessions a significant decrease of psycho-physiological activity was noticed, evidenced by progressively decreasing HR and increasing HRV. These findings suggest that EMDR is associated with patterns of autonomic activity associated with substantial psycho-physiological de-arousal over time.
Variability of maximum systolic amplitude of ΔZ/Δt curve in pregnancy. Perennial observations
NASA Astrophysics Data System (ADS)
Ilyin, I.; Karpov, A.; Korotkova, M.
2010-04-01
Maximum systolic amplitude is quite an important component of the impedance cardiogram ΔZ/Δt curve. Its values make it possible to calculate many hemodynamic indices. Therefore it is necessary to keep informed about monthly, annual and perennial maximum systolic amplitude trend. We can produce the measuring data of the maximum systolic amplitude for a fifteen-year period (from 1994 to 2009). The impedance cardiograms were obtained with the help of an electric impedance analyzer "RA-5" (1 mA, 70 kHz) with disk ECG electrodes. The data analyzed were taken from the pregnant women with non-complicated pregnancy (n=5709). We have analyzed the average monthly and annual changes of the maximum systolic amplitude ΔZ/Δt curve. It allowed us to reveal the six-year periodicity of the maximum systolic amplitude changes. There were discovered statistically significant peak values difference of the amplitude (p>0.001). The data obtained should be taken into consideration when using impedance cardiography in clinical practice. The article is supplied with tables and diagrams.
Sattel, Heribert; Schmidt, Ulrike; Sack, Martin
2018-01-01
ABSTRACT Background: Patients suffering from dissociative disorders (DD) are characterized by an avoidance of aversive stimuli. Clinical experience has shown that DD patients typically avoid the confrontation with their own faces in a mirror (CFM). Objective: To investigate potential CFM-associated self-reported and psychophysiological stress reactions of DD patients, which most likely inform on the still unknown pathophysiology of dysfunctional self-perception in DD. Method: Eighteen DD patients and 18 healthy controls (HCs) underwent CFM. They were assessed for CFM-induced subjective self-reported stress, acute dissociative symptoms and sympathetic and parasympathetic drive using impedance cardiography. Results: DD patients experienced more subjective stress and acute dissociation than HCs upon CFM. Their psychological stress response did not activate the sympathetic and parasympathetic nervous system. Conclusions: In DD patients, CFM constitutes serious self-reported stress and is associated with a blunted autonomic reactivity. Therapeutic approaches promoting self-perception and self-compassion, in particular by using CFM, might serve as goal-oriented diagnostic and therapeutic tools in DD.
Schäflein, Eva; Sattel, Heribert; Schmidt, Ulrike; Sack, Martin
2018-01-01
Background : Patients suffering from dissociative disorders (DD) are characterized by an avoidance of aversive stimuli. Clinical experience has shown that DD patients typically avoid the confrontation with their own faces in a mirror (CFM). Objective : To investigate potential CFM-associated self-reported and psychophysiological stress reactions of DD patients, which most likely inform on the still unknown pathophysiology of dysfunctional self-perception in DD. Method : Eighteen DD patients and 18 healthy controls (HCs) underwent CFM. They were assessed for CFM-induced subjective self-reported stress, acute dissociative symptoms and sympathetic and parasympathetic drive using impedance cardiography. Results : DD patients experienced more subjective stress and acute dissociation than HCs upon CFM. Their psychological stress response did not activate the sympathetic and parasympathetic nervous system. Conclusions : In DD patients, CFM constitutes serious self-reported stress and is associated with a blunted autonomic reactivity. Therapeutic approaches promoting self-perception and self-compassion, in particular by using CFM, might serve as goal-oriented diagnostic and therapeutic tools in DD.
Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review
Bera, Tushar Kanti
2014-01-01
Under the alternating electrical excitation, biological tissues produce a complex electrical impedance which depends on tissue composition, structures, health status, and applied signal frequency, and hence the bioelectrical impedance methods can be utilized for noninvasive tissue characterization. As the impedance responses of these tissue parameters vary with frequencies of the applied signal, the impedance analysis conducted over a wide frequency band provides more information about the tissue interiors which help us to better understand the biological tissues anatomy, physiology, and pathology. Over past few decades, a number of impedance based noninvasive tissue characterization techniques such as bioelectrical impedance analysis (BIA), electrical impedance spectroscopy (EIS), electrical impedance plethysmography (IPG), impedance cardiography (ICG), and electrical impedance tomography (EIT) have been proposed and a lot of research works have been conducted on these methods for noninvasive tissue characterization and disease diagnosis. In this paper BIA, EIS, IPG, ICG, and EIT techniques and their applications in different fields have been reviewed and technical perspective of these impedance methods has been presented. The working principles, applications, merits, and demerits of these methods has been discussed in detail along with their other technical issues followed by present status and future trends. PMID:27006932
Vahabi, Zahra; Amirfattahi, Rasoul; Shayegh, Farzaneh; Ghassemi, Fahimeh
2015-09-01
Considerable efforts have been made in order to predict seizures. Among these methods, the ones that quantify synchronization between brain areas, are the most important methods. However, to date, a practically acceptable result has not been reported. In this paper, we use a synchronization measurement method that is derived according to the ability of bi-spectrum in determining the nonlinear properties of a system. In this method, first, temporal variation of the bi-spectrum of different channels of electro cardiography (ECoG) signals are obtained via an extended wavelet-based time-frequency analysis method; then, to compare different channels, the bi-phase correlation measure is introduced. Since, in this way, the temporal variation of the amount of nonlinear coupling between brain regions, which have not been considered yet, are taken into account, results are more reliable than the conventional phase-synchronization measures. It is shown that, for 21 patients of FSPEEG database, bi-phase correlation can discriminate the pre-ictal and ictal states, with very low false positive rates (FPRs) (average: 0.078/h) and high sensitivity (100%). However, the proposed seizure predictor still cannot significantly overcome the random predictor for all patients.
Cardiovascular indicators of disgust.
Rohrmann, Sonja; Hopp, Henrik
2008-06-01
A bradycardia and an increasing parasympathetic activity are often recommended as characteristic physiological disgust reactions. However, findings concerning the influence of disgust on heart rate and autonomic control are heterogenous. Apart from this, only a few studies examined cardiovascular reactions to disgust, besides heart rate. The aim of this study is a differentiated description of cardiovascular reactions going along with disgust using impedance cardiography. Moreover, it will be surveyed if different cardiovascular responses are associated with content-specific disgust-inductions. One-hundred subjects watched three films: A neutral film (screensaver), a filmclip showing an amputation of the upper extremity and a filmclip displaying a person who is vomiting. The latter films are regarded as disease- and food-related disgust stimuli respectively, representing two superior disgust domains. Subjective, electrodermal and cardiovascular reactions to these films were compared using Repeated Measures ANOVAs. Strong subjective, electrodermal and cardiovascular reactions towards the filmclips with disgusting content were observed. The cardiovascular reactions of the disease- and food-related disgust stimuli differed in subjective and physiological parameters. Thus, a decrease in heart rate could only be observed as a response to disease-related disgust-induction. The observed differences are discussed as an endorsement for a domain-specific organisation of disgust reactions.
A New Frontier for Cardiac Monitoring
NASA Technical Reports Server (NTRS)
2001-01-01
CardioDynamics International Corporation (CDIC) has created the BioZ(TM) System through a Small Business Innovation Research (SBIR) award from Johnson Space Center, providing patients and physicians with a cost-effective and highly accurate monitoring system.The BioZ non-invasive heart monitor is based on a technology known as Impedance Cardiography (ICG). BioZ provides the physician with vital information about the heart's ability to deliver blood to the body, the force one's heart exerts with each beat, and the amount of fluid in the chest. Specially designed bioimpedance sensors placed on the neck and chest monitor 12 different parameters, including cardiac output, contractility, systemic vascular resistance, and thoracic fluid content. These sensors monitor the electrical conductivity of the body-information that is converted into blood flow data and is displayed in real time on a monitoring screen. BioZ.com(TM) and BioZ.pc(TM) are two additional products that incorporate the same sensors present in the original BioZ system. The "com" in BioZ.com stands for cardiac output monitor. This fully integrated system is essentially a smaller version of the BioZ, combining the same abilities with a compact, lightweight design, while providing greater portability.
Heart Rate Variability During Early Adaptation to Space
NASA Technical Reports Server (NTRS)
Toscano, W. B.; Cowings, P. S.
1994-01-01
A recent report hypothesized that episodes of space motion sickness (SMS) were reliably associated with low frequency oscillations (less than 0.03 to less than 0.01 Hz) in heart rate variability. This paper archives a large data set for review of investigators in this field which may facilitate the evaluation of this hypothesis. Continuous recording of Electro-cardiography (ECG) and other measures were made for 6 to 12 hours per day (waking hours) of six Shuttle crewmembers for the first 3 mission days of two separate Shuttle flights. Spectral analyses of heart rate variability during approximately 200 hours of inflight is presented. In addition, nearly 200 hours of data collected on these same individuals during ground tests prior to the mission are presented. The Purpose of this Publication is to document the incidence of low frequency oscillations of heart rate in 4 people exposed to microgravity over a period of five days. In addition, this report contains spectral analyses of heart rate data collected on these same individuals during ground-based mission simulations. By archiving these data in this manner, it is our intention to make this information available to other investigators interested in studying this phenomena.
Silvia, Paul J.; Nusbaum, Emily C.; Eddington, Kari M.; Beaty, Roger E.; Kwapil, Thomas R.
2014-01-01
Motivational approaches to depression emphasize the role of dysfunctional motivational dynamics, particularly diminished reward and incentive processes associated with anhedonia. A study examined how anhedonic depressive symptoms, measured continuously across a wide range of severity, influenced the physiological mobilization of effort during a cognitive task. Using motivational intensity theory as a guide, we expected that the diminished incentive value associated with anhedonic depressive symptoms would reduce effort during a “do your best” challenge (also known as an unfixed or self-paced challenge), in which effort is a function of the value of achieving the task’s goal. Using impedance cardiography, two cardiac autonomic responses were assessed: pre-ejection period (PEP), a measure of sympathetic activity and our primary measure of interest, and respiratory sinus arrhythmia (RSA), a measure of parasympathetic activity. As expected, PEP slowed from baseline to task as anhedonic depressive symptoms increased (as measured with the DASS Depression scale), indicating diminished effort-related sympathetic activity. No significant effects appeared for RSA. The findings support motivational intensity theory as a translational model of effort processes in depression and clarify some inconsistent effects of depressive symptoms on effort-related physiology found in past work. PMID:25431505
Henry, Isaac C; Bernstein, Donald P; Banet, Matt J
2012-01-01
Stroke volume (SV) is the quantity of blood ejected by the cardiac ventricles per each contraction. When SV is multiplied by heart rate, cardiac output is the result. Cardiac output (CO), in conjunction with hemoglobin concentration and arterial oxygen saturation are the cornerstones of oxygen transport. Measurement of CO is important, especially in sick humans suffering from decompensated heart disease and systemic diseases affecting the contractility or loading conditions of the heart. Although reasonably accurate invasive cardiac output methods are available, their use is restricted to those individuals hospitalized in the intensive care units. Thus, a robust noninvasive alternative is considered desirable. Impedance cardiography (ICG) is one such method, but in patients with severe heart disease and/or excess extravascular lung water, the method is inaccurate. This paper concerns the introduction of a new method, transbrachial electrical bioimpedance velocimetry (TBEV). The technique involves passage of a constant magnitude, high frequency, and low amperage ac from the upper arm to the antecubital fossa. In all other respects, the operational aspects of TBEV are consistent with ICG. There is good evidence suggesting that the TBEV waveform and its derivatives are generated by blood resistivity changes only.
Prenatal stress and balance of the child's cardiac autonomic nervous system at age 5-6 years.
van Dijk, Aimée E; van Eijsden, Manon; Stronks, Karien; Gemke, Reinoud J B J; Vrijkotte, Tanja G M
2012-01-01
Autonomic nervous system (ANS) misbalance is a potential causal factor in the development of cardiovascular disease. The ANS may be programmed during pregnancy due to various maternal factors. Our aim is to study maternal prenatal psychosocial stress as a potential disruptor of cardiac ANS balance in the child. Mothers from a prospective birth cohort (ABCD study) filled out a questionnaire at gestational week 16 [IQR 12-20], that included validated instruments for state anxiety, depressive symptoms, pregnancy-related anxiety, parenting daily hassles and job strain. A cumulative stress score was also calculated (based on 80(th) percentiles). Indicators of cardiac ANS in the offspring at age 5-6 years are: pre-ejection period (PEP), heart rate (HR), respiratory sinus arrhythmia (RSA) and cardiac autonomic balance (CAB), measured with electrocardiography and impedance cardiography in resting supine and sitting positions. 2,624 mother-child pairs, only single births, were available for analysis. The stress scales were not significantly associated with HR, PEP, RSA and CAB (p≥0.17). Accumulation of maternal stress was also not associated with HR, PEP, RSA and CAB (p≥0.07). Results did not support the hypothesis that prenatal maternal psychosocial stress deregulates cardiac ANS balance in the offspring, at least in rest, and at the age of five-six years.
A new approach for low-cost noninvasive detection of asymptomatic heart disease at rest.
DeMarzo, Arthur P; Calvin, James E
2007-01-01
It would be useful to have an inexpensive, noninvasive point-of-care test for early detection of asymptomatic heart disease. This study used impedance cardiography (ICG) in a new way to assess heart function that did not use stroke volume or cardiac output. There is a model of the ICG dZ/dt waveform that may be used as a template to represent normal heart function. The hypothesis was that a dZ/dt waveform which deviates from that template should indicate heart dysfunction and therefore heart disease. The objective was to assess the accuracy of this new ICG approach, using echocardiography as the standard. Thirty-four outpatients undergoing echocardiographic testing were tested by ICG while sitting upright and supine. All patients had no symptoms or history of a structural or functional heart disorder. Echocardiographic testing showed 17 patients with abnormalities and 17 as normal. ICG testing yielded 16 true positives for heart dysfunction with 1 false negative (sensitivity = 94%) and 17 true negatives with no false positives (specificity = 100%). Considering that the cost, technical skill, and time required for this ICG test are comparable to those of an electrocardiograph, this new approach has potential as a point-of-care screening test for asymptomatic heart disease.
Sleegers, Willem W. A.; Proulx, Travis
2015-01-01
People maintain systems of beliefs that provide them with a sense of belongingness, control, identity, and meaning, more generally. Recent research shows that when these beliefs are threatened a syndrome of negatively valenced arousal is evoked that motivates people to seek comfort in their ideologies or other personally valued beliefs. In this paper we will provide an overview of this process and discuss areas for future research. Beginning with the neural foundations of meaning violations, we review findings that show the anterior cingulate cortex is responsible for detecting inconsistencies, and importantly, that this is experienced as aversive. Next, we evaluate the evidential support for a psychophysiological arousal response as measured by cardiography and skin conductance. We discuss how current theorizing proposes that subsequent behavioral approach ameliorates the negative arousal and serves as an effective, well-adapted coping response, but we also aim to further integrate this process in the existing threat-compensation literature. Finally, we speculate on whether approach motivation is likely to result when one feels capable of handling the threat, thereby incorporating the biopsychosocial model that distinguishes between challenge and threat into the motivational threat-response literature. We believe the current literature on threat and meaning has much to offer and we aim to provide new incentives for further development. PMID:25620950
Chinese medicine shenfu injection for heart failure: a systematic review and meta-analysis.
Wen-Ting, Song; Fa-Feng, Cheng; Li, Xu; Cheng-Ren, Lin; Jian-Xun, Liu
2012-01-01
Objective. Heart failure (HF) is a global public health problem. Early literature studies manifested that Shenfu injection (SFI) is one of the most commonly used traditional Chinese patent medicine for HF in China. This article intended to systematically evaluate the efficacy and safety of SFI for HF. Methods. An extensive search was performed within 6 English and Chinese electronic database up to November 2011. Ninety-nine randomized controlled trails (RCTs) were collected, irrespective of languages. Two authors extracted data and assessed the trial quality independently. RevMan 5.0.2 was used for data analysis. Results. Compared with routine treatment and/or device support, SFI combined with routine treatment and/or device support showed better effect on clinical effect rate, mortality, heart rate, NT-proBNP and 6-minute walk distance. Results in ultrasonic cardiography also showed that SFI combined with routine treatment improved heart function of HF patients. There were no significant difference in blood pressure between SFI and routine treatment groups. Adverse events were reported in thirteen trails with thirteen specific symptoms, while no serious adverse effect was reported. Conclusion. SFI appear to be effective for treating HF. However, further rigorously designed RCTs are warranted because of insufficient methodological rigor in the majority of included trials.
Transesophageal Echocardiographic Study of Decompression-Induced Venous Gas Emboli
NASA Technical Reports Server (NTRS)
Butler, B. D.; Morris, W. P.
1995-01-01
Transesophageal echo-cardiography was used to evaluate venous bubbles produced in nine anesthetized dogs following decompression from 2.84 bar after 120 min at pressure. In five dogs a pulsed Doppler cuff probe was placed around the inferior vena cava for bubble grade determination. The transesophageal echo images demonstrated several novel or less defined events. In each case where the pulmonary artery was clearly visualized, the venous bubbles were seen to oscillate back and forth several times, bringing into question the effect of coincidental counting in routine bubble grade analysis using precordial Doppler. A second finding was that in all cases, extensive bubbling occurred in the portal veins with complete extraction by the liver sinusoids, with one exception where a portal-to-hepatic venous anastomosis was observed. Compression of the bowel released copious numbers of bubbles into the portal veins, sometimes more than were released into the inferior vena cava. Finally, large masses of foam were routinely observed in the non-dependent regions of the inferior vena cava that not only delayed the appearance of bubbles in the pulmonary artery but also allowed additional opportunity for further reaction with blood products and for coalescence to occur before reaching the pulmonary microcirculation. These novel observations are discussed in relation to the decompression process.
NASA Technical Reports Server (NTRS)
Cowings, Patricia; Toscano, William; Winther, Sean; Martinez, Jacqueline; Dominguez, Margaret
2012-01-01
Susceptibility of healthy astronauts to orthostatic hypotension and presyncope is exacerbated upon return from spaceflight. The effect of altered gravity during space flight and planetary transition on human cardiovascular function is of critical importance to maintenance of astronaut health and safety. Hypovolemia, reduced plasma volume, is suspected to play an important role in cardiovascular deconditioning following exposure to spaceflight, which may lead to increased peripheral resistance, attenuated arterial baroreflex, and changes in cardiac function. A promising countermeasure for post-flight orthostatic intolerance is fluid loading used to restore lost plasma volume by giving crew salt tablets and water prior to re-entry. The main purpose of the proposed study is to define the temporal profile of cardiac responses to simulated 0-G conditions before and following a fluid loading countermeasure. 8 men and 8 women will be tested during 4 hour exposures at 6o head down tilt (HDT). Each subject will be given two exposures to HDT on separate days, one with and one without fluid loading (one liter of 0.9% saline solution). Stand tests (orthostatic stress) will be done before and after each HDT. Cardiac measures will be obtained with both impedance cardiography and echo ultrasound
Social Support Versus Social Evaluation: Unique Effects on Vascular and Myocardial Response Patterns
Christian, Lisa M.; Stoney, Catherine M.
2010-01-01
Objectives This study examined the effects of companion presence and evaluation on cardiovascular reactivity to an acute stressor. Methods Eighty-two women completed a speech task in one of four conditions: with an evaluative companion present, with a nonevaluative companion present, alone while being evaluated by a companion with a video camera, or alone while the companion waited outside. Results A significant interaction between companion condition and evaluative condition on systolic blood pressure was found; women who were evaluated while alone demonstrated significantly greater reactivity than did women who were in the nonevaluative alone condition. Furthermore, both potential for evaluation and the presence of a companion had important influences on hemodynamic parameters underlying the blood pressure response. Specifically, those in evaluative conditions showed greater myocardial responding than those in nonevaluative conditions and those in alone conditions showed greater vascular responding than did those with companions present. Taken together, those in the evaluative alone condition demonstrated systolic blood pressure responses reflecting both myocardial and vascular contributions. Conclusions Social support and social evaluation have unique effects on vascular and myocardial responding. The implications for future research include focus on the stress-buffering model of social support and the value of including impedance cardiography measures in investigations of cardiovascular functioning. PMID:17079702
Development of a wearable multi-frequency impedance cardiography device.
Weyer, Sören; Menden, Tobias; Leicht, Lennart; Leonhardt, Steffen; Wartzek, Tobias
2015-02-01
Cardiovascular diseases as well as pulmonary oedema can be early diagnosed using vital signs and thoracic bio-impedance. By recording the electrocardiogram (ECG) and the impedance cardiogram (ICG), vital parameters are captured continuously. The aim of this study is the continuous monitoring of ECG and multi-frequency ICG by a mobile system. A mobile measuring system, based on 'low-power' ECG, ICG and an included radio transmission is described. Due to the high component integration, a board size of only 6.5 cm×5 cm could be realized. The measured data can be transmitted via Bluetooth and visualized on a portable monitor. By using energy-efficient hardware, the system can operate for up to 18 hs with a 3 V battery, continuously sending data via Bluetooth. Longer operating times can be realized by decreased transfer rates. The relative error of the impedance measurement was less than 1%. The ECG and ICG measurements allow an approximate calculation of the heart stroke volume. The ECG and the measured impedance showed a high correlation to commercial devices (r=0.83, p<0.05). In addition to commercial devices, the developed system allows a multi-frequency measurement of the thoracic impedance between 5-150 kHz.
[Galectin-3 in Patients With Paroxysmal and Persistent Atrial Fibrillation and Metabolic Syndrome].
A, V A; Zaslavskaya, E L; Soboleva, A V; Baranova, E I; Listopad, O V; Nifontov, S E; Nrady, A O; Shlyakhto, E V
2016-06-01
To evaluate serum galectin 3 and to determine the potential clinical value of this parameter in patients with atrial fibrillation - AF (paroxysmal and persistent) and metabolic syndrome (MS). We examined 100 patients with MS (50 with paroxysmal or persistent AF and 50 without arrhythmia) and 50 healthy persons. Serum galectin 3 measured by ELISA method, ECHO cardiography was performed to all examined persons. Galectin 3 in patients with MS and AF was higher, than in patients with MS without arrhythmia and much more higher than galectin 3 in healthy persons 0,72 (0,44;1,36), 0,44 (0,42;1,22) and 0,32 (0,28;0,42) ng/ml (<0,01). In patients with persistent AF levels of galectin 3 is higher than in patients with paroxysmal AF. Positive correlation between the levels of galectin 3 and duration arrhythmia was revealed (r=0,301; p<0,01). Higher level of galectin 3 was revealed in patients with frequent paroxysms of AF and ineffective antiarrhythmic therapy. Marker of myocardial fibrosis serum galectin 3 in patients with atrial fibrillation and metabolic syndrome is higher than in patients with the metabolic syndrome, without this arrhythmia and higher than in healthy controls. In patients with persistent AF level of galectin 3 was higher than in patients with paroxysmal AF.
NASA Astrophysics Data System (ADS)
Ermishkin, V. V.; Kolesnikov, V. A.; Lukoshkova, E. V.; Sonina, R. S.
2013-04-01
The impedance cardiography (ICG) is widely used for beat-to-beat noninvasive evaluation of the left ventricular stroke volume and contractility. It implies the correct determination of the ejection start and end points and the amplitudes of certain peaks in the differentiated impedance cardiogram. An accurate identification of ejection onset by ICG is often problematic, especially in the cardiologic patients, due to peculiar waveforms. Using a simple theoretical model, we tested the hypothesis that two major processes are responsible for the formation of impedance systolic wave: (1) the changes in the heart geometry and surrounding vessels produced by ventricular contraction, which occur during the isovolumic phase and precede ejection, and (2) expansion of aorta and adjacent arteries during the ejection phase. The former process initiates the preejection wave WpE and the latter triggers the ejection wave WEj. The model predicts a potential mechanism of generating the abnormal shapes of dZ/dt due to the presence of preejection waves and explains the related errors in ICG time and amplitude parameters. An appropriate decomposition method is a promising way to avoid the masking effects of these waves and a further step to correct determination of the onset of ejection and the corresponding peak amplitudes from 'pathologically shaped' ICG signals.
Responses to Exercise Differ For Chronic Fatigue Syndrome Patients with Fibromyalgia
Cook, Dane B.; Stegner, Aaron J.; Nagelkirk, Paul R.; Meyer, Jacob D.; Togo, Fumiharu; Natelson, Benjamin H.
2011-01-01
Chronic fatigue syndrome (CFS) and fibromyalgia (FM) are chronic multisymptom illnesses with substantial clinical and diagnostic overlap. We have previously shown that when controlling for aerobic fitness and accounting for comorbid FM, CFS patients do not exhibit abnormal cardiorespiratory responses during maximal aerobic exercise compared to healthy controls, despite differences in pain and exertion. Purpose The purpose of the present study was to examine cardiac and perceptual responses to steady-state, submaximal exercise in CFS patients and healthy controls. Methods Twenty-one CFS patients [13 CFS with comorbid FM (CFS+FM)] and 14 controls completed 20 minutes of submaximal cycling exercise. Impedance cardiography was used to determine cardiac responses during exercise. Systolic blood pressure (SBP), perceived exertion (RPE) and leg-muscle pain were also measured. Data were analyzed using a doubly-multivariate, repeated-measures MANOVA to model the exercise response. Results There was a significant multivariate Time by Group interaction (p < 0.05). The CFS+FM group exhibited an exercise response characterized by higher stoke index, ventilatory equivalents for oxygen and carbon dioxide and RPE, lower SBP and similar HR responses. Conclusions The present results extend upon our previous work with maximal exercise and show that CFS and CFS+FM differ in their responses to steady-state exercise. These results highlight the importance of accounting for comorbid conditions when conducting CFS research, particularly when examining psychophysiological responses to exercise. PMID:22157881
Value of Impedance Cardiography during 6‐Minute Walk Test in Pulmonary Hypertension
Alkukhun, Laith; Arelli, Vineesha; Ramos, José; Newman, Jennie; McCarthy, Kevin; Pichurko, Bohdan; Minai, Omar A.; Dweik, Raed A.
2013-01-01
Abstract Background Methods that predict prognosis and response to therapy in pulmonary hypertension (PH) are lacking. We tested whether the noninvasive estimation of hemodynamic parameters during 6‐minute walk test (6MWT) in PH patients provides information that can improve the value of the test. Methods We estimated hemodynamic parameters during the 6MWT using a portable, signal‐morphology‐based, impedance cardiograph (PhysioFlow Enduro) with real‐time wireless monitoring via a bluetooth USB adapter. Results We recruited 48 subjects in the study (30 with PH and 18 healthy controls). PH patients had significantly lower maximum stroke volume (SV) and CI and slower cardiac output (CO) acceleration and decelerations slopes during the test when compared with healthy controls. In PH patients, CI change was associated with total distance walked (R = 0.62; P < 0.001) and percentage of predicted (R = 0.4, P = 0.03), HR recovery at 1 minute (0.57, P < 0.001), 2 minutes (0.65, P < 0.001), and 3 minutes (0.66, P < 0.001). Interestingly, in PH patients CO change during the test was predominantly related to an increase in SV instead of HR. Conclusions Estimation of hemodynamic parameters such as cardiac index during 6‐minute walk test is feasible and may provide useful information in patients with PH. Clin Trans Sci 2013; Volume #: 1–7 PMID:24330692
Spartano, Nicole L; Heffernan, Kevin S; Dumas, Amy K; Gump, Brooks B
2017-01-01
Cardiovascular reactivity has been associated with future hypertension and cardiovascular mortality. Higher physical activity (PA) has been associated with lower cardiovascular reactivity in adults, but little data is available in children. The purpose of this study was to examine the relationship between PA and cardiovascular reactivity to mental stress in children. Cross-sectional study. This study sample included children from the Oswego Lead Study (n=79, 46% female, 9-11 years old). Impedance cardiography was performed while children participated in a stress response protocol. Children were also asked to wear Actigraph accelerometers on their wrists for 3 days to measure intensity and duration of PA and sedentary time. In multivariable models, moderate to vigorous (MV) PA was associated with lower body mass index (BMI) percentile and lower total peripheral resistance (TPR) response to stress (beta=-0.025, p=0.02; beta=-0.009, p=0.05). After additional adjustment for BMI, MVPA was also associated with lower diastolic blood pressure response to stress (beta=-0.01, p=0.03). Total PA and sedentary time were not associated with BMI or cardiovascular responses to stress. A modest, inverse relation of PA to vascular reactivity to mental stress was observed in children. These data provide confirmatory evidence that the promotion of PA recommendations for children are important for cardiovascular health. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Preejection period can be calculated using R peak instead of Q.
Seery, Mark D; Kondrak, Cheryl L; Streamer, Lindsey; Saltsman, Thomas; Lamarche, Veronica M
2016-08-01
Preejection period (PEP) is a common measure of sympathetic nervous system activation in psychophysiological research, which makes it important to measure reliably for as many participants as possible. PEP is typically calculated as the interval between the onset or peak of the electrocardiogram Q wave and the impedance cardiography B point, but the Q wave can lack clear definition and even its peak is not visible for all participants. We thus investigated the feasibility of using the electrocardiogram R wave peak (Rpeak ) instead of Q because it can be consistently identified with ease and precision. Across four samples (total N = 408), young adult participants completed a variety of minimally metabolically demanding laboratory tasks after a resting baseline. Results consistently supported a close relationship between absolute levels of the Rpeak -B interval and PEP (accounting for approximately 90% of the variance at baseline and 89% during task performance, on average), but for reactivity values, Rpeak -B was practically indistinguishable from PEP (accounting for over 98% of the variance, on average). Given that using Rpeak rather than the onset or peak of Q saves time, eliminates potential subjectivity, and can be applied to more participants (i.e., those without a visible Q wave), findings suggest that Rpeak -B likely provides an adequate estimate of PEP when absolute levels are of interest and clearly does so for within-person changes. © 2016 Society for Psychophysiological Research.
User Interactive Software for Analysis of Human Physiological Data
NASA Technical Reports Server (NTRS)
Cowings, Patricia S.; Toscano, William; Taylor, Bruce C.; Acharya, Soumydipta
2006-01-01
Ambulatory physiological monitoring has been used to study human health and performance in space and in a variety of Earth-based environments (e.g., military aircraft, armored vehicles, small groups in isolation, and patients). Large, multi-channel data files are typically recorded in these environments, and these files often require the removal of contaminated data prior to processing and analyses. Physiological data processing can now be performed with user-friendly, interactive software developed by the Ames Psychophysiology Research Laboratory. This software, which runs on a Windows platform, contains various signal-processing routines for both time- and frequency- domain data analyses (e.g., peak detection, differentiation and integration, digital filtering, adaptive thresholds, Fast Fourier Transform power spectrum, auto-correlation, etc.). Data acquired with any ambulatory monitoring system that provides text or binary file format are easily imported to the processing software. The application provides a graphical user interface where one can manually select and correct data artifacts utilizing linear and zero interpolation and adding trigger points for missed peaks. Block and moving average routines are also provided for data reduction. Processed data in numeric and graphic format can be exported to Excel. This software, PostProc (for post-processing) requires the Dadisp engineering spreadsheet (DSP Development Corp), or equivalent, for implementation. Specific processing routines were written for electrocardiography, electroencephalography, electromyography, blood pressure, skin conductance level, impedance cardiography (cardiac output, stroke volume, thoracic fluid volume), temperature, and respiration
Mukai, C N; Lathers, C M; Charles, J B; Bennett, B S
1994-05-01
Physiologic changes to repetitive hyper- and hypogravity stresses occurring during eight to ten parabolas on NASA's KC-135 aircraft were studied. Hemodynamic responses in 11 subjects in 4 different postures (supine, standing, sitting, and semisupine Space Shuttle launch position) were determined using noninvasive impedance cardiography. Five seconds of heart rate, cardiac index, thoracic fluid index, stroke index, ejection velocity index, and ventricular ejection time data were averaged during four different gravity (g) states: 1.3g (before parabola onset); 1.9g (parabola entry); 0g (parabola peak); and 1.7g (parabola exit) for each subject. The standing position was associated with the largest changes in the cardiovascular response to hypo- and hypergravity. The thoracic fluid index did not indicate a headward redistribution during transition from a simulated launch position to weightlessness. Analysis of the eight to ten parabolas revealed that, in general, values obtained at 1.8g differed from 1.6g, 0g differed from 1.6 and 1.3g, and 1.6g differed from 1.3g. The factors of gravity, thoracic fluid index, and cardiac index exhibited significant differences that were most likely to occur between parabola 1 versus parabolas 6, 7, and 8, and parabola 2 versus parabolas 4 through 8. Only the parameter of thoracic fluid index exhibited significance for parabolas 3 versus parabolas 6 and 7.
Life Satisfaction and Hemodynamic Reactivity to Mental Stress.
Schwerdtfeger, Andreas; Gaisbachgrabner, Kerstin; Traunmüller, Claudia
2017-06-01
Satisfaction with life has been considered a health-protective variable, which could impact cardiovascular morbidity and mortality. However, few studies have examined the physiological pathways involved in the potentially salutary effect of life satisfaction. It was hypothesized that life satisfaction should be associated with a cardiovascular response profile that signals challenge (i.e., higher cardiac output, lower peripheral resistance), rather than threat during a mental stress task. A sample of 75 healthy, medication-free men without clinical signs of psychological disorders who worked full-time and occupied highly demanding positions participated in this study. They performed two mental stress tasks (n-back) with varying degrees of difficulty. The tasks were embedded between a baseline and a recovery period. Cardiovascular and hemodynamic variables (heart rate, blood pressure, cardiac output, total peripheral resistance) were recorded by means of impedance cardiography. Individuals who were more satisfied with their life displayed higher cardiac output and lower peripheral resistance levels during the stress tasks, indicating a challenge rather than a threat profile. Findings were robust when controlled for physical activity, smoking, age, and depressive symptoms. Life satisfaction could be positively correlated with beneficial hemodynamic stress reactivity, indicating that individuals with higher levels of life satisfaction can more adaptively cope with stress. Increased cardiac output and decreased peripheral resistance during stress may constitute one route through which life satisfaction can benefit health.
NASA Technical Reports Server (NTRS)
Mukai, C. N.; Lathers, C. M.; Charles, J. B.; Bennett, B. S.
1994-01-01
Physiologic changes to repetitive hyper- and hypogravity stresses occurring during eight to ten parabolas on NASA's KC-135 aircraft were studied. Hemodynamic responses in 11 subjects in 4 different postures (supine, standing, sitting, and semisupine Space Shuttle launch position) were determined using noninvasive impedance cardiography. Five seconds of heart rate, cardiac index, thoracic fluid index, stroke index, ejection velocity index, and ventricular ejection time data were averaged during four different gravity (g) states: 1.3g (before parabola onset); 1.9g (parabola entry); 0g (parabola peak); and 1.7g (parabola exit) for each subject. The standing position was associated with the largest changes in the cardiovascular response to hypo- and hypergravity. The thoracic fluid index did not indicate a headward redistribution during transition from a simulated launch position to weightlessness. Analysis of the eight to ten parabolas revealed that, in general, values obtained at 1.8g differed from 1.6g, 0g differed from 1.6 and 1.3g, and 1.6g differed from 1.3g. The factors of gravity, thoracic fluid index, and cardiac index exhibited significant differences that were most likely to occur between parabola 1 versus parabolas 6, 7, and 8, and parabola 2 versus parabolas 4 through 8. Only the parameter of thoracic fluid index exhibited significance for parabolas 3 versus parabolas 6 and 7.
Salomon, Kristen; Bylsma, Lauren M; White, Kristi E; Panaite, Vanessa; Rottenberg, Jonathan
2013-10-01
Prior work has repeatedly demonstrated that people who have current major depression exhibit blunted cardiovascular reactivity to acute stressors (e.g., Salomon et al., 2009). A key question regards the psychobiological basis for these deficits, including whether such deficits are depressed mood-state dependent or whether these effects are trait-like and are observed outside of depression episodes in vulnerable individuals. To examine this issue, we assessed cardiovascular reactivity to a speech stressor task and a forehead cold pressor in 50 individuals with current major depressive disorder (MDD), 25 with remitted major depression (RMD), and 45 healthy controls. Heart rate (HR), blood pressure and impedance cardiography were assessed and analyses controlled for BMI and sex. Significant group effects were found for SBP, HR, and PEP for the speech preparation period and HR, CO, and PEP during the speech. For each of these parameters, only the MDD group exhibited attenuated reactivity as well as impaired SBP recovery. Reactivity and recovery in the RMD group more closely resembled the healthy controls. Speeches given by the MDD group were rated as less persuasive than the RMD or healthy controls' speeches. No significant differences were found for the cold pressor. Blunted cardiovascular reactivity and impaired recovery in current major depression may be mood-state dependent phenomena and may be more reflective of motivational deficits than deficits in the physiological integrity of the cardiovascular system. Copyright © 2013 Elsevier B.V. All rights reserved.
Studying the determinant factors leading to congenital heart disease in newborns.
Arjmandnia, Mohammadhossein; Besharati, Mahsa; Rezvan, Sajad
2018-01-01
Congenital heart disease (CHD) is an important cause of death during the 1 st year of life and includes a special group of cardiac diseases that exist from birth. These conditions arise due to the abnormal development of an embryo's normal structures. A case-control study was conducted to investigate the determinant factors leading to CHD. All newborns who have been diagnosed with CHD upon echocardiography in 2013 were considered as cases. The number of samples required was randomly selected from the newborns who lacked CHD on cardiography. The mothers of both groups were handed the questionnaires. SPSS 23 was employed to analyze the data. A statistically significant association was seen between CHD and a positive family history (FH) ( P < 0.001), consanguinity ( P < 0.001), maternal diabetes ( P = 0.004), the use of antiepileptics during the first 45 days of gestation ( P = 0.002), and the mother's education status ( P > 0.001). No significant association was observed between CHD in the newborn and the age below 20 and above 35 years and ( P = 0.11), maternal body mass index (BMI) ( P = 0.44), smoking during the first 45 days of gestation ( P = 0.017), and maternal rheumatologic diseases ( P = 0.4). Newborns are at a greater risk of having CHD born from mothers with a FH of CHD, from consanguineous marriages, history of diabetes, antiepileptic use, and lack of folic acid use. However, no significant associations were found between newborn CHD and maternal age, BMI, or cigarette smoking.
Thomas, M; Heyll, A; Meckenstock, G; Vogt, M; Aul, C
1992-05-08
A 50-year-old man complained of lumbar pains, lack of energy, dysarthria and ataxic gait. Investigation revealed progressive anaemia (haemoglobin initially 10.5 g/dl, later 6.8 g/dl) and thrombocytopenia (initially 67,000/microliters, later 25,000/microliters). In addition he had unexplained pyrexia of up to 39.8 degrees C. Lactate dehydrogenase was 780 U/l and fragmented red cells were noted in the blood film. Because of suspicion of thrombotic thrombocytopenic purpura, treatment with fresh plasma by infusion was immediately initiated. On the third day of treatment he developed left ventricular failure; auscultation revealed a blowing early diastolic murmur over Erb's point together with a spindle-shaped early diastolic murmur over the right second intercostal space. Computed tomography of the skull showed recent haemorrhage into the left half of the cerebellum and an older right posterior infarct. The abdominal ultrasound scan suggested a haemorrhagic spleen infarct. In view of these findings the diagnosis was revised to embolizing aortic endocarditis with aortic reflux (confirmed by colour Doppler echo-cardiography). Aortic valve replacement was performed immediately, and the patient was treated with gentamycin 80 mg/d and teicoplanin 400 mg/d for four weeks. Postoperatively he was given 12 units of platelet concentrate and the platelet count remained stable thereafter (greater than 100,000/microliters). Splenectomy became necessary because the splenic haematoma increased in size during oral anticoagulant therapy. After a 6 week hospital stay the patient was discharged in good condition.
Attenuated heart rate responses to public speaking in individuals with alcohol dependence.
Panknin, Tera L; Dickensheets, Stacey L; Nixon, Sara J; Lovallo, William R
2002-06-01
Because individuals with alcohol dependence (AD) have shown blunted cortisol responses to psychological stress, we assessed whether they also show attenuated cardiovascular responses. This study examined the cardiovascular responses of people meeting DSM-IV criteria for AD to orthostasis and public speaking. Heart rate (HR), stroke volume, cardiac output, total peripheral resistance, mean arterial pressure, systolic blood pressure, and diastolic blood pressure during orthostasis and public speaking were assessed by use of impedance cardiography and Dinamap blood pressure monitoring in 20 AD subjects abstinent for 21 to 28 days and in 10 age-matched controls. Orthostasis consisted of standing, whereas public speaking involved preparing and presenting two speeches. Self-reported mood state was also assessed during the tasks. AD subjects had significantly lower resting BP compared with controls. Cardiovascular responses to orthostasis were similar between groups. AD subjects had attenuated HR during public speaking but reported similar anxiety responses to controls. Comparable cardiovascular responses to orthostasis in controls and AD subjects suggest intact reflex control of circulation. AD subjects had blunted HR responses to public speaking; this is consistent with the attenuated cortisol responses observed in this sample and in previous studies. This suggests a possible alteration in limbic system regulation of hypothalamic and brainstem responses to psychological stress. Cardiovascular responses of AD subjects that are inconsistent with subjective accounts of tension and anxiety suggest a disconnection between perception of threat and resulting physiologic responses in AD subjects.
Ephedrine fails to accelerate the onset of neuromuscular block by vecuronium.
Komatsu, Ryu; Nagata, Osamu; Ozaki, Makoto; Sessler, Daniel I
2003-08-01
The onset time of neuromuscular blocking drugs is partially determined by circulatory factors, including muscle blood flow and cardiac output. We thus tested the hypothesis that a bolus of ephedrine accelerates the onset of vecuronium neuromuscular block by increasing cardiac output. A prospective, randomized study was conducted in 53 patients scheduled for elective surgery. After the induction of anesthesia, the ulnar nerve was stimulated supramaximally every 10 s, and the evoked twitch response of the adductor pollicis was recorded with accelerometry. Patients were maintained under anesthesia with continuous infusion of propofol for 10 min and then randomly assigned to ephedrine 210 microg/kg (n = 27) or an equivalent volume of saline (n = 26). The test solution was given 1 min before the administration of 0.1 mg/kg of vecuronium. Cardiac output was monitored with impedance cardiography. Ephedrine, but not saline, increased cardiac index (17%; P = 0.003). Nonetheless, the onset of 90% neuromuscular block was virtually identical in the patients given ephedrine (183 +/- 41 s) and saline (181 +/- 47 s). There was no correlation between cardiac index and onset of the blockade. We conclude that the onset of the vecuronium-induced neuromuscular block is primarily determined by factors other than cardiac output. The combination of ephedrine and vecuronium thus cannot be substituted for rapid-acting nondepolarizing muscle relaxants. Ephedrine increased cardiac index but failed to speed onset of neuromuscular block with vecuronium. We conclude that ephedrine administration does not shorten the onset time of vecuronium.
Salomon, Kristen; Bylsma, Lauren M.; White, Kristi E.; Panaite, Vanessa; Rottenberg, Jonathan
2015-01-01
Prior work has repeatedly demonstrated that people who have current major depression exhibit blunted cardiovascular reactivity to acute stressors (e.g., Salomon et al., 2009). A key question regards the psychobiological basis for these deficits, including whether such deficits are depressed mood-state dependent or whether these effects are trait-like and are observed outside of depression episodes invulnerable individuals. To examine this issue, we assessed cardiovascular reactivity to a speech stressor task and a forehead cold pressor in 50 individuals with current major depressive disorder (MDD), 25 with remitted major depression (RMD), and 45 healthy controls. Heart rate (HR), blood pressure and impedance cardiography were assessed and analyses controlled for BMI and sex. Significant group effects were found for SBP, HR, and PEP for the speech preparation period and HR, CO, and PEP during the speech. For each of these parameters, only the MDD group exhibited attenuated reactivity as well as impaired SBP recovery. Reactivity and recovery in the RMD group more closely resembled the healthy controls. Speeches given by the MDD group were rated as less persuasive than the RMD or healthy controls' speeches. No significant differences were found for the cold pressor. Blunted cardiovascular reactivity and impaired recovery in current major depression may be mood-state dependent phenomena and may be more reflective of motivational deficits than deficits in the physiological integrity of the cardiovascular system. PMID:23756147
NASA Astrophysics Data System (ADS)
Hildebrandt, Wulf; Schütze, Harald; Stegemann, J.
Rapid quantification of the human baro-reflex control of heart rate has been achieved on a beat-by-beat basis using a neck-chamber with quick ECG-triggered pressure changes. Referring to recent findings on heart rate and stroke volume, the present study uses this technique to compare cardiac output as well as blood pressure changes in supine and upright position to investigate feedback effects and to confirm postural reflex modifications not revealed by RR-interval changes. A suction profile starting at +40 mmHg and running 7 steps of pressure decrease down to -65 mmHg was examined in 0° and 90° tilting position while beat-by-beat recordings were done of heart rate, stroke volume (impedance-cardiography) and blood pressure (Finapres tm) (n=16). The percentual heart rate decrease failed to be significantly different between positions. A suction-induced stroke volume increase led to a cardiac output almost maintained when supine and significantly increased when upright. A decrease in all blood pressure values was found during suction, except for systolic values in upright position which increased. Conclusively, (a) it is confirmed that different inotropy accounts for the seen gravitational effect on the cardiac output not represented by heart rate; (b) identical suction levels in different positions lead to different stimuli at the carotid receptor. This interference has to be considered in microgravity studies by beat-by-beat measurement of cardiac output and blood pressure.
Effects of posture on upper and lower limb peripheral resistance following submaximal cycling.
Swan, P D; Spitler, D L; Todd, M K; Maupin, J L; Lewis, C L; Darragh, P M
1989-09-01
The purpose of this study was to determine postural effects on upper and lower limb peripheral resistance (PR) after submaximal exercise. Twelve subjects (six men and six women) completed submaximal cycle ergometer tests (60% age-predicted maximum heart rate) in the supine and upright seated positions. Each test included 20 minutes of rest, 20 minutes of cycling, and 15 minutes of recovery. Stroke volume and heart rate were determined by impedance cardiography, and blood pressure was measured by auscultation during rest, immediately after exercise, and at minutes 1-5, 7.5, 10, 12.5, and 15 of recovery. Peripheral resistance was calculated from values of mean arterial pressure and cardiac output. No significant (p less than 0.05) postural differences in PR were noted during rest for either limb. Immediately after exercise, PR decreased (55% to 61%) from resting levels in both limbs, independent of posture. Recovery ankle PR values were significantly different between postures. Upright ankle PR returned to 92% of the resting level within four minutes of recovery, compared to 76% of the resting level after 15 minutes in the supine posture. Peripheral resistance values in the supine and upright arm were not affected by posture and demonstrated a gradual pattern of recovery similar to the supine ankle recovery response (85% to 88% of rest within 15 minutes). The accelerated recovery rate of PR after upright exercise may result from local vasoconstriction mediated by a central regulatory response to stimulation from gravitational pressure on lower body circulation.
McGrath, Susan P; Ryan, Kathy L; Wendelken, Suzanne M; Rickards, Caroline A; Convertino, Victor A
2011-02-01
The primary objective of this study was to determine whether alterations in the pulse oximeter waveform characteristics would track progressive reductions in central blood volume. We also assessed whether changes in the pulse oximeter waveform provide an indication of blood loss in the hemorrhaging patient before changes in standard vital signs. Pulse oximeter data from finger, forehead, and ear pulse oximeter sensors were collected from 18 healthy subjects undergoing progressive reduction in central blood volume induced by lower body negative pressure (LBNP). Stroke volume measurements were simultaneously recorded using impedance cardiography. The study was conducted in a research laboratory setting where no interventions were performed. Pulse amplitude, width, and area under the curve (AUC) features were calculated from each pulse wave recording. Amalgamated correlation coefficients were calculated to determine the relationship between the changes in pulse oximeter waveform features and changes in stroke volume with LBNP. For pulse oximeter sensors on the ear and forehead, reductions in pulse amplitude, width, and area were strongly correlated with progressive reductions in stroke volume during LBNP (R(2) ≥ 0.59 for all features). Changes in pulse oximeter waveform features were observed before profound decreases in arterial blood pressure. The best correlations between pulse features and stroke volume were obtained from the forehead sensor area (R(2) = 0.97). Pulse oximeter waveform features returned to baseline levels when central blood volume was restored. These results support the use of pulse oximeter waveform analysis as a potential diagnostic tool to detect clinically significant hypovolemia before the onset of cardiovascular decompensation in spontaneously breathing patients.
Kuznetsov, Alexey N; Rybalko, Natalia V; Daminov, Vadim D; Luft, Andreas R
2013-01-01
Background. Stroke frequently leaves survivors with hemiparesis. To prevent persistent deficits, rehabilitation may be more effective if started early. Early training is often limited because of orthostatic reactions. Tilt-table stepping robots and functional electrical stimulation (FES) may prevent these reactions. Objective. This controlled convenience sample study compares safety and feasibility of robotic tilt-table training plus FES (ROBO-FES) and robotic tilt-table training (ROBO) against tilt-table training alone (control). A preliminary assessment of efficacy is performed. Methods. Hemiparetic ischemic stroke survivors (age 58.3 ± 1.2 years, 4.6 ± 1.2 days after stroke) were assigned to 30 days of ROBO-FES (n = 38), ROBO (n = 35), or control (n = 31) in addition to conventional physical therapy. Impedance cardiography and transcranial doppler sonography were performed before, during, and after training. Hemiparesis was assessed using the British Medical Research Council (MRC) strength scale. Results. No serious adverse events occurred; 8 patients in the tilt-table group prematurely quit the study because of orthostatic reactions. Blood pressure and CBFV dipped <10% during robot training. In 52% of controls mean arterial pressure decreased by ≥20%. ROBO-FES increased leg strength by 1.97 ± 0.88 points, ROBO by 1.50 ± 0.85 more than control (1.03 ± 0.61, P < 0.05). CBFV increased in both robotic groups more than in controls (P < 0.05). Conclusions. Robotic tilt-table exercise with or without FES is safe and may be more effective in improving leg strength and cerebral blood flow than tilt table alone.
Quantifying and Reducing Posture-Dependent Distortion in Ballistocardiogram Measurements
Javaid, Abdul Q.; Wiens, Andrew D.; Fesmire, N. Forrest; Weitnauer, Mary A.; Inan, Omer T.
2015-01-01
Ballistocardiography is a non-invasive measurement of the mechanical movement of the body caused by cardiac ejection of blood. Recent studies have demonstrated that ballistocardiogram (BCG) signals can be measured using a modified home weighing scale, and used to track changes in myocardial contractility and cardiac output. With this approach, the BCG can potentially be used both for preventive screening and for chronic disease management applications. However, for achieving high signal quality, subjects are required to stand still on the scale in an upright position for the measurement; the effects of intentional (for user comfort) or unintentional (due to user error) modifications in the position or posture of the subject during the measurement have not been investigated in the existing literature. In this study, we quantified the effects of different standing and seated postures on the measured BCG signals, and on the most salient BCG-derived features compared to reference standard measurements (e.g., impedance cardiography). We determined that the standing upright posture led to the least distorted signals as hypothesized, and that the correlation between BCG-derived timing interval features (R-J interval) and the pre-ejection period, PEP (measured using ICG), decreased significantly with impaired posture or sitting position. We further implemented two novel approaches to improve the PEP estimates from other standing and sitting postures, using system identification and improved J-wave detection methods. These approaches can improve the usability of standing BCG measurements in unsupervised settings (i.e. the home), by improving the robustness to non-ideal posture, as well as enabling high quality seated BCG measurements. PMID:26058064
The influence of social stress on time perception and psychophysiological reactivity.
van Hedger, Kathryne; Necka, Elizabeth A; Barakzai, Anam K; Norman, Greg J
2017-05-01
Time perception is a fundamental component of everyday life. Although time can be measured using standard units, the relationship between an individual's experience of perceived time and a standard unit is highly sensitive to context. Stressful and threatening stimuli have been previously shown to produce time distortion effects, such that individuals perceive the stimuli as lasting for different amounts of time as compared to a standard unit. As a highly social species, humans are acutely sensitive to social stressors; however, time distortion effects have not been studied in the context of social stress. We collected psychophysiological (electrocardiogram and impedance cardiography) and time perception data before, during, and after a modified version of the Trier Social Stress Test for 42 participants. Based on prior theories and evidence from the time perception literature, we hypothesized that experiencing a stressful event would result in time distortion. This hypothesis was supported by the data, with individuals on average reproducing short and long duration negative and positive stimuli as lasting longer after experiencing social stress, t(41) = -3.55, p = .001, and t(41) = -4.12, p < .001 for negative stimuli, and t(41) = -2.43, p = .02, and t(41) = -3.07, p = .004 for positive stimuli. However, changes in time perception were largely unrelated to psychophysiological reactivity to social stress. These findings are in line with some other studies of time distortion, and provide evidence for the interoceptive salience model of time perception. Implications for mechanisms of time distortion are discussed. © 2017 Society for Psychophysiological Research.
Shibata, Yohei; Ishii, Hideki; Suzuki, Susumu; Tanaka, Akihito; Tatami, Yosuke; Harata, Shingo; Ota, Tomoyuki; Shimbo, Yusaku; Takayama, Yohei; Kunimura, Ayako; Hirayama, Kenshi; Harada, Kazuhiro; Osugi, Naohiro; Murohara, Toyoaki
2017-05-01
Previous studies have shown that aortic valve calcification (AVC) was associated with cardiovascular events and mortality. On the other hand, periprocedural myocardial injury (PMI) in percutaneous coronary intervention (PCI) is a well-known predictor of subsequent mortality and poor clinical outcomes. The purpose of the study was to assess the hypothesis that the presence of AVC could predict PMI in PCI. This study included 370 patients treated with PCI for stable angina pectoris. AVC was defined as bright echoes >1 mm on one or more cusps of the aortic valve on ultrasound cardiography (UCG). PMI was defined as an increase in high-sensitivity troponin T level of >5 times the upper normal limit (>0.070 ng/ml) at 24 hours after PCI. AVC was detected in 45.9% of the patients (n=170). The incidence of PMI was significantly higher in the patients with AVC than in those without AVC (43.5% vs 21.0%, p<0.001). The presence of AVC independently predicted PMI after adjusting for other significant variables (odds ratio 2.26, 95% confidence interval 1.37-3.74, p=0.002). Other predictors were male sex, age, estimated glomerular filtration rate, and total stent length. Furthermore to predict PMI, adding AVC to the established risk factors significantly improved the area under the receiver operating characteristic curves, from 0.68 to 0.72, of the PMI prediction model (p=0.025). The presence of AVC detected in UCG could predict the incidence of PMI.
Impaired cardiorespiratory coupling in young normotensives with a family history of hypertension.
Xie, Lin; Li, Mengjun; Dang, Shijie; Li, Chaomin; Wang, Xiaoni; Liu, Binbin; Mei, Mengqi; Zhang, Jianbao
2018-05-24
Although recent animal studies have highlighted the importance of cardiorespiratory coupling in the pathogenesis of hypertension, little research has assessed the cardiorespiratory coupling in humans at high risk of developing hypertension. The aim of this study was to investigate the cardiorespiratory coupling in healthy young individuals genetically predisposed to hypertension at both rest and mental stress conditions. We studied 39 normotensive male participants [21 with (FH+) and 18 without (FH-) a family history of hypertension]. Electrocardiography, impedance cardiography, beat-to-beat blood pressure and respiratory signal were simultaneously recorded during 5 min of rest and 5 min of mental arithmetic task (MAT). Stroke volume, cardiac output, systemic vascular resistance, baroreflex sensitivity and aortic pulse wave velocity were calculated. Autonomic activity was approximated noninvasively by the spectral analysis of cardiovascular variability. Respiratory sinus arrhythmia (RSA) and cardiorespiratory phase synchronization (CRPS) were used to define the amplitude and phase relationships of cardiorespiratory coupling. All resting parameters were similar between FH- and FH+ groups except resting CRPS, which was lower in FH+ group. Furthermore, the changes in hemodynamic parameters and cardiovascular variability at MAT were comparable in FH- and FH+ groups. Moreover, MAT elicited a decrease in CRPS of FH- group, whereas CRPS of participants in FH+ group remained unchanged during MAT. Healthy offspring of hypertensive parents have lower CRPS at rest, indicating an early impairment of cardiorespiratory coupling. Furthermore, CRPS decreased under mental stress in participants without a family history of hypertension, whereas this reactivity of CRPS was absent in participants with a family history of hypertension.
Kuznetsov, Alexey N.; Rybalko, Natalia V.; Daminov, Vadim D.; Luft, Andreas R.
2013-01-01
Background. Stroke frequently leaves survivors with hemiparesis. To prevent persistent deficits, rehabilitation may be more effective if started early. Early training is often limited because of orthostatic reactions. Tilt-table stepping robots and functional electrical stimulation (FES) may prevent these reactions. Objective. This controlled convenience sample study compares safety and feasibility of robotic tilt-table training plus FES (ROBO-FES) and robotic tilt-table training (ROBO) against tilt-table training alone (control). A preliminary assessment of efficacy is performed. Methods. Hemiparetic ischemic stroke survivors (age 58.3 ± 1.2 years, 4.6 ± 1.2 days after stroke) were assigned to 30 days of ROBO-FES (n = 38), ROBO (n = 35), or control (n = 31) in addition to conventional physical therapy. Impedance cardiography and transcranial doppler sonography were performed before, during, and after training. Hemiparesis was assessed using the British Medical Research Council (MRC) strength scale. Results. No serious adverse events occurred; 8 patients in the tilt-table group prematurely quit the study because of orthostatic reactions. Blood pressure and CBFV dipped <10% during robot training. In 52% of controls mean arterial pressure decreased by ≥20%. ROBO-FES increased leg strength by 1.97 ± 0.88 points, ROBO by 1.50 ± 0.85 more than control (1.03 ± 0.61, P < 0.05). CBFV increased in both robotic groups more than in controls (P < 0.05). Conclusions. Robotic tilt-table exercise with or without FES is safe and may be more effective in improving leg strength and cerebral blood flow than tilt table alone. PMID:23691432
Crisafulli, Antonio; Tangianu, Flavio; Tocco, Filippo; Concu, Alberto; Mameli, Ombretta; Mulliri, Gabriele; Caria, Marcello A
2011-08-01
Brief episodes of nonlethal ischemia, commonly known as "ischemic preconditioning" (IP), are protective against cell injury induced by infarction. Moreover, muscle IP has been found capable of improving exercise performance. The aim of the study was the comparison of standard exercise performances carried out in normal conditions with those carried out following IP, achieved by brief muscle ischemia at rest (RIP) and after exercise (EIP). Seventeen physically active, healthy male subjects performed three incremental, randomly assigned maximal exercise tests on a cycle ergometer up to exhaustion. One was the reference (REF) test, whereas the others were performed after the RIP and EIP sessions. Total exercise time (TET), total work (TW), and maximal power output (W(max)), oxygen uptake (VO(2max)), and pulmonary ventilation (VE(max)) were assessed. Furthermore, impedance cardiography was used to measure maximal heart rate (HR(max)), stroke volume (SV(max)), and cardiac output (CO(max)). A subgroup of volunteers (n = 10) performed all-out tests to assess their anaerobic capacity. We found that both RIP and EIP protocols increased in a similar fashion TET, TW, W(max), VE(max), and HR(max) with respect to the REF test. In particular, W(max) increased by ∼ 4% in both preconditioning procedures. However, preconditioning sessions failed to increase traditionally measured variables such as VO(2max), SV(max,) CO(max), and anaerobic capacity(.) It was concluded that muscle IP improves performance without any difference between RIP and EIP procedures. The mechanism of this effect could be related to changes in fatigue perception.
Árbol, Javier Rodríguez; Perakakis, Pandelis; Garrido, Alba; Mata, José Luis; Fernández-Santaella, M Carmen; Vila, Jaime
2017-03-01
The preejection period (PEP) is an index of left ventricle contractility widely used in psychophysiological research. Its computation requires detecting the moment when the aortic valve opens, which coincides with the B point in the first derivative of impedance cardiogram (ICG). Although this operation has been traditionally made via visual inspection, several algorithms based on derivative calculations have been developed to enable an automatic performance of the task. However, despite their popularity, data about their empirical validation are not always available. The present study analyzes the performance in the estimation of the aortic valve opening of three popular algorithms, by comparing their performance with the visual detection of the B point made by two independent scorers. Algorithm 1 is based on the first derivative of the ICG, Algorithm 2 on the second derivative, and Algorithm 3 on the third derivative. Algorithm 3 showed the highest accuracy rate (78.77%), followed by Algorithm 1 (24.57%) and Algorithm 2 (13.82%). In the automatic computation of PEP, Algorithm 2 resulted in significantly more missed cycles (48.57%) than Algorithm 1 (6.3%) and Algorithm 3 (3.5%). Algorithm 2 also estimated a significantly lower average PEP (70 ms), compared with the values obtained by Algorithm 1 (119 ms) and Algorithm 3 (113 ms). Our findings indicate that the algorithm based on the third derivative of the ICG performs significantly better. Nevertheless, a visual inspection of the signal proves indispensable, and this article provides a novel visual guide to facilitate the manual detection of the B point. © 2016 Society for Psychophysiological Research.
Shibata, Yohei; Suzuki, Susumu; Tanaka, Akihito; Tatami, Yosuke; Harata, Shingo; Ota, Tomoyuki; Shimbo, Yusaku; Takayama, Yohei; Kunimura, Ayako; Hirayama, Kenshi; Harada, Kazuhiro; Osugi, Naohiro; Murohara, Toyoaki
2017-01-01
Aims: Previous studies have shown that aortic valve calcification (AVC) was associated with cardiovascular events and mortality. On the other hand, periprocedural myocardial injury (PMI) in percutaneous coronary intervention (PCI) is a well-known predictor of subsequent mortality and poor clinical outcomes. The purpose of the study was to assess the hypothesis that the presence of AVC could predict PMI in PCI. Methods: This study included 370 patients treated with PCI for stable angina pectoris. AVC was defined as bright echoes > 1 mm on one or more cusps of the aortic valve on ultrasound cardiography (UCG). PMI was defined as an increase in high-sensitivity troponin T level of > 5 times the upper normal limit (> 0.070 ng/ml) at 24 hours after PCI. Results: AVC was detected in 45.9% of the patients (n = 170). The incidence of PMI was significantly higher in the patients with AVC than in those without AVC (43.5% vs 21.0%, p < 0.001). The presence of AVC independently predicted PMI after adjusting for other significant variables (odds ratio 2.26, 95% confidence interval 1.37–3.74, p = 0.002). Other predictors were male sex, age, estimated glomerular filtration rate, and total stent length. Furthermore to predict PMI, adding AVC to the established risk factors significantly improved the area under the receiver operating characteristic curves, from 0.68 to 0.72, of the PMI prediction model (p = 0.025). Conclusion: The presence of AVC detected in UCG could predict the incidence of PMI. PMID:27733732
Cerebral blood velocity and other cardiovascular responses to 2 days of head-down tilt
NASA Technical Reports Server (NTRS)
Frey, Mary A. B.; Mader, Thomas H.; Bagian, James P.; Charles, John B.; Meehan, Richard T.
1993-01-01
Spaceflight induces a cephalad redistribution of fluid volume and blood flow within the human body, and space motion sickness, which is a problem during the first few days of space flight, could be related to these changes in fluid status and in blood flow of the cerebrum and vestibular system. To evaluate possible changes in cerebral blood flow during simulated weightlessness, we measured blood velocity in the middle cerebral artery (MCA) along with retinal vascular diameters, intraocular pressure, impedance cardiography, and sphygmomanometry on nine men (26.2 +/- 6.6 yr) morning and evening for 2 days during continuous 10 deg head-down tilt (HDT). When subjects went from seated to head-down bed rest, their heart rate and retinal diameters decreased, and intraocular pressures increased. After 48 h of HDT, blood flow velocity in the MCA was decreased and thoracic impedance was increased, indicating less fluid in the thorax. Percent changes in blood flow velocities in the MCA after 48 h of HDT were inversely correlated with percent changes in retinal vascular diameters. Blood flow velocities in the MCA were inversely correlated (intersubject) with arterial pressures and retinal vascular diameters. Heart rate, stroke volume, cardiac output, systolic arterial pressure, and at times pulse pressure and blood flow velocities in the MCA were greater in the evening. Total peripheral resistance was higher in the morning. Although cerebral blood velocity is reduced after subjects are head down for 2 days, the inverse relationship with retinal vessel diameters, which have control analogous to that of cerebral vessels, indicates cerebral blood flow is not reduced.
Athanasopoulos, Dimitris; Louvaris, Zafeiris; Cherouveim, Evgenia; Andrianopoulos, Vasilis; Roussos, Charis; Zakynthinos, Spyros
2010-01-01
We investigated whether expiratory muscle loading induced by the application of expiratory flow limitation (EFL) during exercise in healthy subjects causes a reduction in quadriceps muscle blood flow in favor of the blood flow to the intercostal muscles. We hypothesized that, during exercise with EFL quadriceps muscle blood flow would be reduced, whereas intercostal muscle blood flow would be increased compared with exercise without EFL. We initially performed an incremental exercise test on eight healthy male subjects with a Starling resistor in the expiratory line limiting expiratory flow to ∼ 1 l/s to determine peak EFL exercise workload. On a different day, two constant-load exercise trials were performed in a balanced ordering sequence, during which subjects exercised with or without EFL at peak EFL exercise workload for 6 min. Intercostal (probe over the 7th intercostal space) and vastus lateralis muscle blood flow index (BFI) was calculated by near-infrared spectroscopy using indocyanine green, whereas cardiac output (CO) was measured by an impedance cardiography technique. At exercise termination, CO and stroke volume were not significantly different during exercise, with or without EFL (CO: 16.5 vs. 15.2 l/min, stroke volume: 104 vs. 107 ml/beat). Quadriceps muscle BFI during exercise with EFL (5.4 nM/s) was significantly (P = 0.043) lower compared with exercise without EFL (7.6 nM/s), whereas intercostal muscle BFI during exercise with EFL (3.5 nM/s) was significantly (P = 0.021) greater compared with that recorded during control exercise (0.4 nM/s). In conclusion, increased respiratory muscle loading during exercise in healthy humans causes an increase in blood flow to the intercostal muscles and a concomitant decrease in quadriceps muscle blood flow. PMID:20507965
Widnes, Christian; Flo, Kari; Acharya, Ganesh
2017-01-01
Placental blood flow is closely associated with fetal growth and wellbeing. Recent studies suggest that there are differences in blood flow between male and female fetuses. We hypothesized that sexual dimorphism exists in fetal and placental blood flow at 22-24 weeks of gestation. This was a prospective cross-sectional study of 520 healthy pregnant women. Blood flow velocities of the middle cerebral artery (MCA), umbilical artery (UA), umbilical vein (UV) and the uterine arteries (UtA) were measured using Doppler ultrasonography. UV and UtA diameters were measured using two-dimensional ultrasonography and power Doppler angiography. Volume blood flows (Q) of the UV and UtA were calculated. Maternal haemodynamics was assessed with impedance cardiography. UtA resistance (R uta ) was computed as MAP/Q uta . UA PI was significantly (p = 0.008) higher in female fetuses (1.19 ± 0.15) compared with male fetuses (1.15 ± 0.14). MCA PI, cerebro-placental ratio (MCA PI/UA PI), Q uv, UtA PI, Q uta and R uta were not significantly different between groups. At delivery, the mean birth weight and placental weight of female infants (3504 g and 610 g) were significantly (p = 0.0005 and p = 0.039) lower than that of the male infants (3642 g and 634 g). We have demonstrated sexual dimorphism in UA PI, a surrogate for placental vascular resistance, at 22-24 weeks of gestation. Therefore, it would be useful to know when this difference emerges and whether it translates into blood flow differences that may impact upon the fetal growth trajectory. Copyright © 2016 Elsevier Ltd. All rights reserved.
Zhang, Qing; Fung, Jeffrey Wing-Hong; Chan, Yat-Sun; Chan, Hamish Chi-Kin; Lin, Hong; Chan, Skiva; Yu, Cheuk-Man
2008-02-29
Cardiac resynchronization therapy (CRT) is an effective therapy for heart failure patients with electromechanical delay. Optimization of atrioventricular interval (AVI) is a cardinal component for the benefits. However, it is unknown if the AVI needs to be re-optimized during long-term follow-up. Thirty-one patients (66+/-11 years, 20 males) with sinus rhythm who received CRT underwent serial optimization of AVI at day 1, 3-month and during long-term follow-up by pulse Doppler echocardiography (PDE). At long-term follow-up, the optimal AVI and cardiac output (CO) estimated by non-invasive impedance cardiography (ICG) were compared with those by PDE. The follow-up was 16+/-11 months. There was no significant difference in the mean optimal AVI when compared between any 2 time points among day 1 (99+/-30 ms), 3-month (97+/-28 ms) and long-term follow-up (94+/-28 ms). However, in individual patient, the optimal AVI remained unchanged only in 14 patients (44%), and was shortened in 12 (38%) and lengthened in 6 patients (18%). During long-term follow-up, although the mean optimal AVIs obtained by PDE or ICG (94+/-28 vs. 92+/-29 ms) were not different, a discrepancy was found in 14 patients (45%). For the same AVI, the CO measured by ICG was systematically higher than that by PDE (3.5+/-0.8 Vs. 2.7+/-0.6 L/min, p<0.001). Optimization of AVI after CRT appears necessary during follow-up as it was readjusted in 55% of patients. Although AVI optimization by ICG was feasible, further studies are needed to confirm its role in optimizing AVI after CRT.
Aatola, Heikki; Koivistoinen, Teemu; Tuominen, Heikki; Juonala, Markus; Lehtimäki, Terho; Viikari, Jorma S A; Raitakari, Olli T; Kähönen, Mika; Hutri-Kähönen, Nina
2017-09-01
Elevated blood pressure (BP) in childhood has been associated with increased adult arterial stiffness, the independent predictor of cardiovascular and all-cause mortality. The favorable BP change from childhood to adulthood and the risk of high adult arterial stiffness has not been reported. We examined the effect of child and adult BP on pulse wave velocity (PWV) assessed in adulthood among 1540 white adults followed-up for 27 years since baseline (1980, aged 6-18 years). Childhood elevated BP was defined according to the tables from the National High Blood Pressure Education Program. In adulthood, BP was classified as elevated if systolic BP ≥120 mm Hg, diastolic BP ≥80 mm Hg, or self-reported use of antihypertensive medications. PWV was measured in 2007 by whole-body impedance cardiography, and high PWV was defined as values at or above the age-, sex-, and heart rate-specific 80th percentile. Individuals with persistently elevated BP and individuals with normal child but elevated adult BP had increased risk of high adult PWV (relative risk [95% confidence interval], 3.18 [2.22-4.55] and 2.64 [1.79-3.88], respectively) in comparison with individuals with normal (both child and adult) BP. In contrast, individuals with elevated BP in childhood but not in adulthood did not have significantly increased risk of high PWV (relative risk [95% confidence interval], 1.26[0.80-1.99]). The results were consistent when different definitions for child and adult elevated BP were applied. These findings highlight the importance of BP control in the primary prevention of cardiovascular diseases. © 2017 American Heart Association, Inc.
Cardiac autonomic function and hot flashes among perimenopausal and postmenopausal women.
Gibson, Carolyn J; Mendes, Wendy Berry; Schembri, Michael; Grady, Deborah; Huang, Alison J
2017-07-01
Abnormalities in autonomic function are posited to play a pathophysiologic role in menopausal hot flashes. We examined relationships between resting cardiac autonomic activity and hot flashes in perimenopausal and postmenopausal women. Autonomic function was assessed at baseline and 12 weeks among perimenopausal and postmenopausal women (n = 121, mean age 53 years) in a randomized trial of slow-paced respiration for hot flashes. Pre-ejection period (PEP), a marker of sympathetic activation, was measured with impedance cardiography. Respiratory sinus arrhythmia (RSA), a marker of parasympathetic activation, was measured with electrocardiography. Participants self-reported hot flash frequency and severity in 7-day symptom diaries. Analysis of covariance models were used to relate autonomic function and hot flash frequency and severity at baseline, and to relate changes in autonomic function to changes in hot flash frequency and severity over 12 weeks, adjusting for age, body mass index, and intervention assignment. PEP was not associated with hot flash frequency or severity at baseline or over 12 weeks (P > 0.05 for all). In contrast, there was a trend toward greater frequency of moderate-to-severe hot flashes with higher RSA at baseline (β = 0.43, P = 0.06), and a positive association between change in RSA and change in frequency of moderate-to-severe hot flashes over 12 weeks (β = 0.63, P = 0.04). Among perimenopausal and postmenopausal women with hot flashes, variations in hot flash frequency and severity were not explained by variations in resting sympathetic activation. Greater parasympathetic activation was associated with more frequent moderate-to-severe hot flashes, which may reflect increased sensitivity to perceiving hot flashes.
Ferreira, J; Seoane, F; Lindecrantz, K
2013-01-01
Personalised Health Systems (PHS) that could benefit the life quality of the patients as well as decreasing the health care costs for society among other factors are arisen. The purpose of this paper is to study the capabilities of the System-on-Chip Impedance Network Analyser AD5933 performing high speed single frequency continuous bioimpedance measurements. From a theoretical analysis, the minimum continuous impedance estimation time was determined, and the AD5933 with a custom 4-Electrode Analog Front-End (AFE) was used to experimentally determine the maximum continuous impedance estimation frequency as well as the system impedance estimation error when measuring a 2R1C electrical circuit model. Transthoracic Electrical Bioimpedance (TEB) measurements in a healthy subject were obtained using 3M gel electrodes in a tetrapolar lateral spot electrode configuration. The obtained TEB raw signal was filtered in MATLAB to obtain the respiration and cardiogenic signals, and from the cardiogenic signal the impedance derivative signal (dZ/dt) was also calculated. The results have shown that the maximum continuous impedance estimation rate was approximately 550 measurements per second with a magnitude estimation error below 1% on 2R1C-parallel bridge measurements. The displayed respiration and cardiac signals exhibited good performance, and they could be used to obtain valuable information in some plethysmography monitoring applications. The obtained results suggest that the AD5933-based monitor could be used for the implementation of a portable and wearable Bioimpedance plethysmograph that could be used in applications such as Impedance Cardiography. These results combined with the research done in functional garments and textile electrodes might enable the implementation of PHS applications in a relatively short time from now.
Hemodynamic effects of nitroglycerin ointment in emergency department patients.
Mumma, Bryn E; Dhingra, Kapil R; Kurlinkus, Charley; Diercks, Deborah B
2014-08-01
Nitroglycerin ointment is commonly used in the treatment of emergency department (ED) patients with suspected acute heart failure (AHF) or suspected acute coronary syndrome (ACS), but its hemodynamic effects in this population are not well described. Our objective was to assess the effect of nitroglycerin ointment on mean arterial pressure (MAP) and systemic vascular resistance (SVR) in ED patients receiving nitroglycerin. We hypothesized that nitroglycerin ointment would result in a reduction of MAP and SVR in the acute treatment of patients. We conducted a prospective, observational pilot study in a convenience sample of adult patients from a single ED who were treated with nitroglycerin ointment. Impedance cardiography was used to measure MAP, SVR, cardiac output (CO), stroke volume (SV), and thoracic fluid content (TFC) at baseline and at 30, 60, and 120 min after application of nitroglycerin ointment. Mixed effects regression models with random slope and random intercept were used to analyze changes in hemodynamic parameters from baseline to 30, 60, and 120 min after adjusting for age, sex, and final ED diagnosis of AHF. Sixty-four subjects with mean age of 55 years (interquartile range, 48-67 years) were enrolled; 59% were male. In the adjusted analysis, MAP and TFC decreased after application of nitroglycerin ointment (p=0.001 and p=0.043, respectively). Cardiac index, CO, SVR, and SV showed no change (p=0.113, p=0.085, p=0.570, and p=0.076, respectively) over time. Among ED patients who are treated with nitroglycerin ointment, MAP and TFC decrease over time. However, other hemodynamic parameters do not change after application of nitroglycerin ointment in these patients. Copyright © 2014 Elsevier Inc. All rights reserved.
Hemodynamic Effects of Nitroglycerin Ointment in Emergency Department Patients
Mumma, Bryn E.; Dhingra, Kapil R.; Kurlinkus, Charley; Diercks, Deborah B.
2014-01-01
Background Nitroglycerin ointment is commonly used in the treatment of emergency department (ED) patients with suspected acute heart failure (AHF) or suspected acute coronary syndrome (ACS), but its hemodynamic effects in this population are not well described. Objectives Our objective was to assess effect of nitroglycerin ointment on mean arterial pressure (MAP) and systemic vascular resistance (SVR) in ED patients receiving nitroglycerin. We hypothesized that nitroglycerin ointment would result in a reduction of MAP and SVR in the acute treatment of patients. Methods We conducted a prospective, observational pilot study in a convenience sample of adult patients from a single ED who were treated with nitroglycerin ointment. Impedance cardiography was used to measure MAP, SVR, cardiac output (CO), stroke volume (SV), and thoracic fluid content (TFC) at baseline and at 30, 60, and 120 minutes following application of nitroglycerin ointment. Mixed effects regression models with random slope and random intercept were used to analyze changes in hemodynamic parameters from baseline to 30, 60, and 120 minutes after adjusting for age, sex, and final ED diagnosis of AHF. Results Sixty-four subjects with mean age 55 years (IQR 48-67) were enrolled; 59% were male. In the adjusted analysis, MAP and TFC decreased following application of nitroglycerin ointment (p=0.001 and p=0.043, respectively). CI, CO, SVR, and SV showed no change (p=0.113, p=0.085, p=0.570, and p=0.076, respectively) over time. Conclusions Among ED patients who are treated with nitroglycerin ointment, MAP and TFC decrease over time. However, other hemodynamic parameters do not change following application of nitroglycerin ointment in these patients. PMID:24698507
A new mouse model of metabolic syndrome and associated complications
Wang, Yun; Zheng, Yue; Nishina, Patsy M; Naggert, Jürgen K.
2010-01-01
Metabolic Syndrome (MS) encompasses a clustering of risk factors for cardiovascular disease, including obesity, insulin resistance, and dyslipidemia. We characterized a new mouse model carrying a dominant mutation, C57BL/6J-Nmf15/+ (B6-Nmf15/+), which develops additional complications of MS such as adipose tissue inflammation and cardiomyopathy. A backcross was used to genetically map the Nmf15 locus. Mice were examined in the CLAMS™ animal monitoring system, and dual energy X-ray absorptiometry and blood chemistry analyses were performed. Hypothalamic LepR, SOCS1 and STAT3 phosphorylation were examined. Cardiac function was assessed by Echo- and Electro Cardiography. Adipose tissue inflammation was characterized by in situ hybridization and measurement of Jun kinase activity. The Nmf15 locus mapped to distal mouse chromosome 5 with a LOD score of 13.8. Nmf15 mice developed obesity by 12 weeks of age. Plasma leptin levels were significantly elevated in pre-obese Nmf15 mice at 8 weeks of age and an attenuated STAT3 phosphorylation in the hypothalamus suggests a primary leptin resistance. Adipose tissue from Nmf15 mice showed a remarkable degree of inflammation and macrophage infiltration as indicated by expression of the F4/80 marker and increased phosphorylation of JNK1/2. Lipidosis was observed in tubular epithelial cells and glomeruli of the kidney. Nmf15 mice demonstrate both histological and pathophysiological evidence of cardiomyopathy. The Nmf15 mouse model provides a new entry point into pathways mediating leptin resistance and obesity. It is one of few models that combine many aspects of metabolic syndrome and can be useful for testing new therapeutic approaches for combating obesity complications, particularly cardiomyopathy. PMID:19398498
Psychophysiological Correlates of Systemic Inflammation in Black and White Men
Lockwood, Kimberly G.; Jennings, J. Richard; Matthews, Karen A.
2016-01-01
Inflammation plays a critical role in the pathophysiology of cardiovascular disease (CVD) and levels of circulating inflammatory markers are associated with future CVD risk. However, the physiological mechanisms that control systemic levels of circulating inflammatory markers are not well understood. Here, we explore possible autonomic nervous system mechanisms by testing whether resting and stressor-evoked cardiovascular responses are associated with two markers of systemic inflammation: interleukin(IL)-6 and C-reactive protein (CRP). Subjects were 159 Black and 129 White men (M = 33.0 years) who completed a laboratory protocol including an anger recall speech task. Electrocardiography and impedance cardiography data were collected during a resting baseline, the speech task, and a final recovery period. Hierarchical regressions tested whether resting or stressor-evoked levels of heart rate (HR), high-frequency heart rate variability (HF-HRV), pre-ejection period (PEP), and pulse transit time (PTT) were associated with CRP or IL-6. Higher resting HR was associated with higher CRP (β = .19, p = .003) and IL-6 (β = .13, p < .05). Similarly, shorter resting PTT was associated with higher CRP (β = −.21, p < .001) and IL-6 (β = −.14, p = .02). In addition, greater stressor-evoked decreases in HF-HRV were associated with higher CRP (β = −.14, p = .01). Associations were independent of age, race, body mass index (BMI), smoking behavior, and socioeconomic status. Resting HF-HRV and PEP were also associated with CRP and IL-6, but associations were not significant after controlling for BMI and smoking behavior. These findings indicate that resting HR and PTT, as well stressor-evoked HF-HRV reactivity, are associated with systemic inflammation. Our results suggest that both tonic and stressor-evoked sympathetic and parasympathetic nervous system activity may contribute to regulation of systemic inflammation. PMID:27568363
Malfatto, Gabriella; Della Rosa, Francesco; Rella, Valeria; Villani, Alessandra; Branzi, Giovanna; Blengino, Simonetta; Giglio, Alessia; Facchini, Mario; Parati, Gianfranco
2014-04-01
Optimization of inotropic treatment in worsening heart failure sometimes requires invasive hemodynamic assessment in selected patients. Impedance cardiography (ICG) may be useful for a noninvasive hemodynamic evaluation. ICG was performed in 40 patients (69 ± 8 years; left ventricular ejection fraction 27.5 ± 5.6%; New York Heart Association 3.18 ± 0.34; Interagency Registry for Mechanically Assisted Circulatory Support 5.48 ± 0.96, before and after infusion of Levosimendan (0.1–0.2 µg/kg per min for up to 24 h). Echocardiogram, ICG [measuring cardiac index (CI), total peripheral resistances (TPRs) and thoracic fluid content (TFC)] and plasma levels of brain natriuretic peptide (BNP) were obtained; in nine patients, right heart catheterization was also carried out. When right catheterization and ICG were performed simultaneously, a significant relationship was observed between values of CI and TPR, and between TFC and pulmonary wedge pressure. ICG detected the Levosimendan-induced recovery of the hemodynamic status, associated with improved systolic and diastolic function and reduction in BNP levels. One-year mortality was 4.4%. At multivariate analysis, independent predictors of mortality were: no improvement in the severity of mitral regurgitation, a persistent restrictive filling pattern (E/E’ > 15), a reduction of BNP levels below 30% and a change below 10% in CI, TPR and TFC. When combined, absence of hemodynamic improvement at ICG could predict 1-year mortality with better sensitivity (86%) and specificity (85%) than the combination of echocardiographic and BNP criteria only (sensitivity 80% and specificity 36%). Noninvasive hemodynamic evaluation of heart failure patients during infusion of inodilator drugs is reliable and may help in their prognostic stratification.
Järvelä, K; Koskinen, M; Kaukinen, S; Kööbi, T
2001-04-01
To compare the effects of hypertonic (7.5%) saline (HS), normal (0.9%) saline (NS), and 6% hydroxyethyl starch (HES) on extracellular fluid volumes in the early postoperative period after cardiopulmonary bypass. A prospective, randomized, double-blind study. University teaching hospital. Forty-eight patients scheduled for elective coronary artery bypass graft surgery. Patients were randomly allocated to receive 4 mL/kg of HS, NS, or HES during 30 minutes when volume loading was needed during the postoperative rewarming period in the intensive care unit. Plasma volume was measured using a dilution of iodine-125-labeled human serum albumin. Extracellular water and cardiac output were measured by whole-body impedance cardiography. Plasma volume had increased by 19 +/- 7% in the HS group and by 10 +/- 3% in the NS group (p = 0.001) at the end of the study fluid infusion. After 1-hour follow-up time, the plasma volume increase was greatest (23 +/- 8%) in the group receiving HES (p < 0.001). The increase of extracellular water was greater than the infused volume in the HS and HES groups at the end of the infusion. One-hour diuresis after the study infusion was greater in the HS group (536 +/- 280 mL) than in the NS (267 +/- 154 mL, p = 0.006) and HES groups (311 +/- 238 mL, p = 0.025). The effect of HS on plasma volume was short-lasting, but it stimulated excretion of excess body fluid accumulated during cardiopulmonary bypass and cardiac surgery. HS may be used in situations in which excess free water administration is to be avoided but the intravascular volume needs correction. Copyright 2001 by W.B. Saunders Company
Postprandial hypotension in older adults: Can it be prevented by drinking water before the meal?
Grobéty, Bastien; Grasser, Erik Konrad; Yepuri, Gayathri; Dulloo, Abdul G; Montani, Jean-Pierre
2015-10-01
An important consequence of ageing is a tendency for postprandial blood pressure to decline, which can lead to fainting. As a possible countermeasure, we investigated in healthy older adults the impact of drinking water before a breakfast meal on postprandial cardiovascular and autonomic functions. After a stable cardiovascular baseline recording for at least 20 min, twelve older adult (67 ± 1 y) test subjects ingested, in a crossover study design, either 100 mL or 500 mL of tap water over 4 min, which was followed by the consumption of the test breakfast meal (1708 kJ) over a period of 15 min. Then, cardiovascular recordings were resumed for 90 min after the meal. Eleven young (25 ± 1 y) and healthy subjects served as a control group. Measurements included beat-to-beat blood pressure, heart rate, impedance cardiography and autonomic variables. In older adults, systolic and diastolic blood pressure started to decline around 30 min after the meal, with the lowest values around 60 min; these effects were not observed in the young control group. Postprandial systolic blood pressure decreased between 30 and 90 min to a greater extent in response to 100 mL than to 500 mL (-6.4 vs. -3.3 mmHg, P < 0.05). Drinking 500 mL of water tended to increase stroke volume, cardiac output and vagal markers to a greater extent than 100 mL. Our data suggest that drinking a large volume (500 mL) of water before a meal may attenuate postprandial hypotension in older adults. Copyright © 2014 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Gayda, Mathieu; Gremeaux, Vincent; Bherer, Louis; Juneau, Martin; Drigny, Joffrey; Dupuy, Olivier; Lapierre, Gabriel; Labelle, Véronique; Fortier, Annik; Nigam, Anil
2017-01-01
Chronic exercise has been shown to prevent or slow age-related decline in cognitive functions in otherwise healthy, asymptomatic individuals. We sought to assess cognitive function in a stable coronary heart disease (CHD) sample and its relationship to cerebral oxygenation-perfusion, cardiac hemodynamic responses, and [Formula: see text] peak compared to age-matched and young healthy control subjects. Twenty-two young healthy controls (YHC), 20 age-matched old healthy controls (OHC) and 25 patients with stable CHD were recruited. Cognitive function assessment included short term-working memory, perceptual abilities, processing speed, cognitive inhibition and flexibility and long-term verbal memory. Maximal cardiopulmonary function (gas exchange analysis), cardiac hemodynamic (impedance cardiography) and left frontal cerebral oxygenation-perfusion (near-infra red spectroscopy) were measured during and after a maximal incremental ergocycle test. Compared to OHC and CHD, YHC had higher [Formula: see text] peak, maximal cardiac index (CI max), cerebral oxygenation-perfusion (ΔO2 Hb, ΔtHb: exercise and recovery) and cognitive function (for all items) (P<0.05). Compared to OHC, CHD patients had lower [Formula: see text] peak, CI max, cerebral oxygenation-perfusion (during recovery) and short term-working memory, processing speed, cognitive inhibition and flexibility and long-term verbal memory (P<0.05). [Formula: see text] peak and CI max were related to exercise cerebral oxygenation-perfusion and cognitive function (P<0.005). Cerebral oxygenation-perfusion (exercise) was related to cognitive function (P<0.005). Stable CHD patients have a worse cognitive function, a similar cerebral oxygenation/perfusion during exercise but reduced one during recovery vs. their aged-matched healthy counterparts. In the all sample, cognitive functions correlated with [Formula: see text] peak, CI max and cerebral oxygenation-perfusion.
The Effect of Posture on Cheyne-Stokes Respirations and Hemodynamics in Patients with Heart Failure
Soll, Bruce A.G.; Keong Yeo, Khung; Davis, James W.; Seto, Todd B.; Schatz, Irwin J.; Shen, Edward N.
2009-01-01
Study Objectives: Cheyne-Stokes respirations occur in 40% of patients with heart failure. Orthopnea is a cardinal symptom of heart failure and may affect the patient's sleeping angle. The objective of this study was to assess the respiratory and hemodynamic response to sleeping angle in a group of subjects with stable heart failure. Design: Twenty-five patients underwent overnight polysomnography with simultaneous and continuous impedance cardiographic monitoring. Sleeping polysomnographic and impedance cardiographic data were recorded. Setting: The study was conducted in a sleep center. Patients: All 25 patients had clinically stable heart failure and left ventricular ejection fractions < 40%. Interventions: The patients slept at 0°, 15°, 30°, and 45° in random order. Measurements and Results: Seventeen patients had Cheyne-Stokes apneas (index > 5/h) and 23 patients had hypopneas (index > 5/h). The hypopnea index showed no response to sleeping angle. The Cheyne-Stokes apnea index decreased with increasing sleeping angle (P < 0.001). This effect was seen only during supine sleep and non-rapid eye movement sleep and was absent in non-supine sleep, rapid eye movement sleep, and during periods of wakefulness. Thoracic fluid content index and left ventricular hemodynamics measured by impedance cardiography showed no response to sleeping angle. Conclusions: Changing the heart failure patient's sleeping angle from 0° to 45° results in a significant decrease in Cheyne-Stokes apneas. This decrease occurs on a constant base of hypopneas. The changes in Cheyne-Stokes apneas are not related to changes in lung congestion and left ventricular hemodynamics. Citation: Soll BAG; Yeo KK; Davis JW; Seto TB; Schatz IJ; Shen EN. The effect of posture on Cheyne-Stokes respirations and hemodynamics in patients with heart failure. SLEEP 2009;32(11):1499-1506. PMID:19928389
McLaughlin, Katie A.; Sheridan, Margaret A.; Alves, Sonia; Mendes, Wendy Berry
2014-01-01
OBJECTIVE Disruptions in stress response system development have been posited as mechanisms linking child maltreatment (CM) to psychopathology. Existing theories predict elevated sympathetic nervous system (SNS) reactivity following CM, but evidence for this is inconsistent. We present a novel framework for conceptualizing stress reactivity following CM using the biopsychosocial model of challenge and threat. We predicted that in the context of a social-evaluative stressor, maltreated adolescents would exhibit a threat pattern of reactivity, involving SNS activation paired with elevated vascular resistance and blunted cardiac output (CO) reactivity. METHODS A sample of 168 adolescents (mean age=14.9 years) participated. Recruitment targeted maltreated adolescents; 38.2% qualified as maltreated. Electrocardiogram, impedance cardiography, and blood pressure were acquired at rest and during an evaluated social stressor (Trier Social Stress Test). Pre-ejection period (PEP), CO, and total peripheral resistance (TPR) reactivity were computed during task preparation, speech-delivery, and verbal mental-arithmetic. Internalizing and externalizing symptoms were assessed. RESULTS Maltreatment was unrelated to PEP reactivity during preparation or speech, but maltreated adolescents had reduced PEP reactivity during math. Maltreatment exposure (F(1,145)=3.8-9.4, p=.053-<.001) and severity (β=−.10-.12, p=.030-.007) were associated with significantly reduced CO reactivity during all components of the stress-task and marginally associated with elevated TPR reactivity (F(1,145)=3.8-9.4, p=.053-<.001; β=.07-.11, p=.11-.009, respectively). Threat reactivity was negatively associated with externalizing symptoms. CONCLUSIONS Child maltreatment is associated with a dysregulated pattern of physiological reactivity consistent with theoretical conceptualizations of threat but not previously examined in relation to maltreatment, suggesting a more nuanced pattern of stress reactivity than predicted by current theoretical models. PMID:25170753
A real-time approach for heart rate monitoring using a Hilbert transform in seismocardiograms.
Jafari Tadi, Mojtaba; Lehtonen, Eero; Hurnanen, Tero; Koskinen, Juho; Eriksson, Jonas; Pänkäälä, Mikko; Teräs, Mika; Koivisto, Tero
2016-11-01
Heart rate monitoring helps in assessing the functionality and condition of the cardiovascular system. We present a new real-time applicable approach for estimating beat-to-beat time intervals and heart rate in seismocardiograms acquired from a tri-axial microelectromechanical accelerometer. Seismocardiography (SCG) is a non-invasive method for heart monitoring which measures the mechanical activity of the heart. Measuring true beat-to-beat time intervals from SCG could be used for monitoring of the heart rhythm, for heart rate variability analysis and for many other clinical applications. In this paper we present the Hilbert adaptive beat identification technique for the detection of heartbeat timings and inter-beat time intervals in SCG from healthy volunteers in three different positions, i.e. supine, left and right recumbent. Our method is electrocardiogram (ECG) independent, as it does not require any ECG fiducial points to estimate the beat-to-beat intervals. The performance of the algorithm was tested against standard ECG measurements. The average true positive rate, positive prediction value and detection error rate for the different positions were, respectively, supine (95.8%, 96.0% and ≃0.6%), left (99.3%, 98.8% and ≃0.001%) and right (99.53%, 99.3% and ≃0.01%). High correlation and agreement was observed between SCG and ECG inter-beat intervals (r > 0.99) for all positions, which highlights the capability of the algorithm for SCG heart monitoring from different positions. Additionally, we demonstrate the applicability of the proposed method in smartphone based SCG. In conclusion, the proposed algorithm can be used for real-time continuous unobtrusive cardiac monitoring, smartphone cardiography, and in wearable devices aimed at health and well-being applications.
[Circulatory Function Tests for Home & Community Use.
Shimetani, Naoto
2016-05-01
Currently, the main circulatory function-testing tools for home use are blood pressure monitors and elec- trocardiography devices. Just like blood pressure monitors that are already widespread for home use, some devices with an electrocardiographic function have recently become available for purchase for personal use by the general public. On the other hand, clinic equipment on loan from doctors to patients in need can perform circulatory function tests like 24-hour ambulatory blood pressure monitoring (ABPM), Holter monitoring, and real-time electrocardiography. We introduce the actual clinical usage of ABPM and real-time electro- cardiography, and discuss the usefulness of these procedures. ABPM uses a blood pressure measurement device worn on the body for 24 hours a day to measure blood pressure at regular intervals. This makes it possible to check blood pressure changes throughout the day in a way in which conventional home-use blood pressure monitors cannot, like during sleep. This method al- lows the identification of masked hypertension like early-morning and nocturnal hypertension, stress hyper- tension including workplace hypertension, and white coat hypertension that only occurs in the doctor's office. Under routine care, there are few opportunities to perform electrocardiography at the time a patient is experiencing symptoms. Now, real-time electrocardiography has begun to be used in routine care, and pa- tients can record an electrocardiogram by themselves anytime, anywhere, and send the data by telephone or the Internet for analysis and diagnosis. Transmission-capable electrocardiography devices can play an im- portant role in the event of dangerous symptoms like arrhythmia, angina, or acute myocardial infarction. The spread of ABPM and event heart monitors is likely to make the early treatment and prevention of stroke and heart disease possible. We are expecting rapid development in this field in the future.
Cerebro- and Cardio-vascular Responses to Energy Drink in Young Adults: Is there a Gender Effect?
Monnard, Cathríona R; Montani, Jean-Pierre; Grasser, Erik K
2016-01-01
Energy drinks (EDs) are suspected to induce potential adverse cardiovascular effects and have recently been shown to reduce cerebral blood flow velocity (CBFV) in young, healthy subjects. Gender differences in CBFV in response to EDs have not previously been investigated, despite the fact that women are more prone to cardiovascular disturbances such as neurocardiogenic syncope than men. Therefore, the aim of this study was to explore gender differences in cerebrovascular and cardiovascular responses to EDs. We included 45 subjects in a retrospective analysis of pooled data from two previous randomized trials carried out in our laboratory with similar protocols. Beat-to-beat blood pressure, impedance cardiography, transcranial Doppler, and end-tidal carbon dioxide (etCO2) measurements were made for at least 20 min baseline and for 80 min following the ingestion of 355 mL of a sugar-sweetened ED. Gender and time differences in cerebrovascular and cardiovascular parameters were investigated. CBFV was significantly reduced in response to ED, with the greatest reduction observed in women compared with men (-12.3 ± 0.8 vs. -9.7 ± 0.8%, P < 0.05). Analysis of variance indicated significant time (P < 0.01) and gender × time (P < 0.01) effects. The percentage change in CBFV in response to ED was independent of body weight and etCO2. No significant gender difference in major cardiovascular parameters in response to ED was observed. ED ingestion reduced CBFV over time, with a greater reduction observed in women compared with men. Our results have potential implications for women ED consumers, as well as high-risk individuals.
Vogiatzis, Ioannis; Andrianopoulos, Vasileios; Louvaris, Zafeiris; Cherouveim, Evgenia; Spetsioti, Stavroula; Vasilopoulou, Maroula; Athanasopoulos, Dimitrios
2011-07-01
In this study, we wished to determine whether the observed reduction in quadriceps muscle oxygen availability, reported during repetitive bouts of isometric exercise in simulated sailing efforts (i.e. hiking), is because of restricted muscle blood flow. Six national-squad Laser sailors initially performed three successive 3-min hiking bouts followed by three successive 3-min cycling tests sustained at constant intensities reproducing the cardiac output recorded during each of the three hiking bouts. The blood flow index (BFI) was determined from assessment of the vastus lateralis using near-infrared spectroscopy in association with the light-absorbing tracer indocyanine green dye, while cardiac output was determined from impedance cardiography. At equivalent cardiac outputs (ranging from 10.3±0.5 to 14.8±0.86 L · min(-1)), the increase from baseline in vastus lateralis BFI across the three hiking bouts (from 1.1±0.2 to 3.1±0.6 nM · s(-1)) was lower (P = 0.036) than that seen during the three cycling bouts (from 1.1±0.2 to 7.2±1.4 nM · s(-1)) (Cohen's d: 3.80 nM · s(-1)), whereas the increase from baseline in deoxygenated haemoglobin (by ∼17.0±2.9 μM) (an index of tissue oxygen extraction) was greater (P = 0.006) during hiking than cycling (by ∼5.3±2.7 μM) (Cohen's d: 4.17 μM). The results suggest that reduced vastus lateralis muscle oxygen availability during hiking arises from restricted muscle blood flow in the isometrically acting quadriceps muscles.
Can echocardiographic findings predict falls in older persons?
van der Velde, Nathalie; Stricker, Bruno H Ch; Roelandt, Jos R T C; Ten Cate, Folkert J; van der Cammen, Tischa J M
2007-07-25
The European and American guidelines state the need for echocardiography in patients with syncope. 50% of older adults with syncope present with a fall. Nonetheless, up to now no data have been published addressing echocardiographic abnormalities in older fallers. In order to determine the association between echocardiographic abnormalities and falls in older adults, we performed a prospective cohort study, in which 215 new consecutive referrals (age 77.4, SD 6.0) of a geriatric outpatient clinic of a Dutch university hospital were included. During the previous year, 139 had experienced a fall. At baseline, all patients underwent routine two-dimensional and Doppler echocardiography. Falls were recorded during a three-month follow-up. Multivariate adjustment for confounders was performed with a Cox proportional hazards model. 55 patients (26%) fell at least once during follow-up. The adjusted hazard ratio of a fall during follow-up was 1.35 (95% CI, 1.08-1.71) for pulmonary hypertension, 1.66 (95% CI, 1.01 to 2.89) for mitral regurgitation, 2.41 (95% CI, 1.32 to 4.37) for tricuspid regurgitation and 1.76 (95% CI, 1.03 to 3.01) for pulmonary regurgitation. For aortic regurgitation the risk of a fall was also increased, but non-significantly (hazard ratio, 1.57 [95% CI, 0.85 to 2.92]). Trend analysis of the severity of the different regurgitations showed a significant relationship for mitral, tricuspid and pulmonary valve regurgitation and pulmonary hypertension. Echo (Doppler) cardiography can be useful in order to identify risk indicators for falling. Presence of pulmonary hypertension or regurgitation of mitral, tricuspid or pulmonary valves was associated with a higher fall risk. Our study indicates that the diagnostic work-up for falls in older adults might be improved by adding an echo (Doppler) cardiogram in selected groups.
Zeng, Shao-ying; Shi, Ji-jun; Li, Hong; Zhang, Zhi-wei; Li, Yu-fen
2010-08-01
To simplify the methods of transcatheter mapping and ablation in the pediatric patients with left posterior fascicular tachycardia. While in sinus rhythm, the fascicular potential can be mapped at the posterior septal region (1 - 2 cm below inferior margin of orifice of coronary sinus vein), which display a biphasic wave before ventricular wave, and exist equipotential lines between them. When the fascicular potential occurs 20 ms later than the bundle of His' potential, radiofrequency was applied. Before applying radiofrequency, catheter position must be observed using double angle viewing (LAO 45°RAO 30°), and it should be made sure that the catheter is not at His' bundle. If the electrocardiogram displays left posterior fascicular block, the correct region is identified and ablation can continue for 60 s. Electrocardiogram monitoring should continue for 24 - 48 hours after operation, and notice abnormal repolarization after termination of ventricular tachycardia. Aspirin [2 - 3 mg/(kg·d)] was used for 3 months, and antiarrhythmic drug was discontinued. Surface electrocardiogram, chest X-ray and ultrasound cardiography were rechecked 1 d after operation. Follow-up was made at 1 month and 3 months post-discharge. Recheck was made half-yearly or follow-up was done by phone from then on. Fifteen pediatric patients were ablated successfully, and their electrocardiograms all displayed left posterior fascicular block after ablation. None of the patients had recurrences during the 3 to 12 months follow-up period. In one case, the electrocardiogram did not change after applying radiofrequency ablation and the ventricular tachycardia remained; however, on second attempt after remapping, the electrocardiogram did change. The radiofrequency lasted for 90 seconds and ablation was successful. This case had no recurrences at 6 months follow-up. Transcatheter ablation of the fascicular potential in pediatric patients with left posterior fascicular tachycardia can simplify mapping, reduce operative difficulty and produce a distinct endpoint for ablation.
Michael, Scott; Jay, Ollie; Graham, Kenneth S; Davis, Glen M
2017-08-01
Systolic time intervals (STIs) provide noninvasive insights into cardiac sympathetic neural activity (cSNA). As the effect of exercise intensity on postexercise STI recovery is unclear, this study investigated the STI recovery profile after different exercise intensities. Eleven healthy males cycled for 8 min at 3 separate intensities: LOW (40%-45%), MOD (75%-80%), and HIGH (90%-95%) of heart-rate (HR) reserve. Bio-impedance cardiography was used to assess STIs - primarily pre-ejection period (PEP; inversely correlated with cSNA), as well as left ventricular ejection time (LVET) and PEP:LVET - during 10 min seated recovery immediately postexercise. Heart-rate variability (HRV), i.e., natural-logarithm of root mean square of successive differences (Ln-RMSSD), was calculated as an index of cardiac parasympathetic neural activity (cPNA). Higher preceding exercise intensity elicited a slower recovery of HR and Ln-RMSSD (p < 0.001), and these measures did not return to baseline by 10 min following any intensity (p ≤ 0.009). Recovery of STIs was also slower following higher intensity exercise (p ≤ 0.002). By 30 s postexercise, higher preceding intensity resulted in a lower PEP (98 ± 14 ms, 75 ± 6 ms, 66 ± 5 ms for LOW, MOD, and HIGH, respectively, p < 0.001). PEP recovered to baseline (143 ± 11 ms) by 5 min following LOW (139 ± 13 ms, p = 0.590) and by 10 min following MOD (145 ± 17 ms, p = 0.602), but was still suppressed at 10 min following HIGH (123 ± 21 ms, p = 0.012). Higher preceding exercise intensity attenuated the recovery of indices for cSNA (from STIs) and cPNA (from HRV) in a graded dose-response fashion. While exercise intensity must be considered, acute recovery may be a valuable period during which to concurrently monitor these noninvasive indices, to identify potentially abnormal cardiac autonomic responses.
Oral N-acetylcysteine and exercise tolerance in mild chronic obstructive pulmonary disease.
Hirai, Daniel M; Jones, Joshua H; Zelt, Joel T; da Silva, Marianne L; Bentley, Robert F; Edgett, Brittany A; Gurd, Brendon J; Tschakovsky, Michael E; O'Donnell, Denis E; Neder, J Alberto
2017-05-01
Heightened oxidative stress is implicated in the progressive impairment of skeletal muscle vascular and mitochondrial function in chronic obstructive pulmonary disease (COPD). Whether accumulation of reactive oxygen species contributes to exercise intolerance in the early stages of COPD is unknown. The purpose of the present study was to determine the effects of oral antioxidant treatment with N -acetylcysteine (NAC) on respiratory, cardiovascular, and locomotor muscle function and exercise tolerance in patients with mild COPD. Thirteen patients [forced expiratory volume in 1 s (FEV 1 )-to-forced vital capacity ratio < lower limit of normal (LLN) and FEV 1 ≥ LLN) were enrolled in a double-blind, randomized crossover study to receive NAC (1,800 mg/day) or placebo for 4 days. Severe-intensity constant-load exercise tests were performed with noninvasive measurements of central hemodynamics (stroke volume, heart rate, and cardiac output via impedance cardiography), arterial blood pressure, pulmonary ventilation and gas exchange, quadriceps muscle oxygenation (near-infrared spectroscopy), and estimated capillary blood flow. Nine patients completed the study with no major adverse clinical effects. Although NAC elevated plasma glutathione by ~27% compared with placebo ( P < 0.05), there were no differences in exercise tolerance (placebo: 325 ± 47 s, NAC: 336 ± 51 s), central hemodynamics, arterial blood pressure, pulmonary ventilation or gas exchange, locomotor muscle oxygenation, or capillary blood flow from rest to exercise between conditions ( P > 0.05 for all). In conclusion, modulation of plasma redox status with oral NAC treatment was not translated into beneficial effects on central or peripheral components of the oxygen transport pathway, thereby failing to improve exercise tolerance in nonhypoxemic patients with mild COPD. NEW & NOTEWORTHY Acute antioxidant treatment with N -acetylcysteine (NAC) elevated plasma glutathione but did not modulate central or peripheral components of the O 2 transport pathway, thereby failing to improve exercise tolerance in patients with mild chronic obstructive pulmonary disease (COPD). Copyright © 2017 the American Physiological Society.
Tahvanainen, Anna; Leskinen, Miia; Koskela, Jenni; Ilveskoski, Erkki; Alanko, Juha; Kähönen, Mika; Kööbi, Tiit; Lehtimäki, Lauri; Moilanen, Eeva; Mustonen, Jukka; Pörsti, Ilkka
2009-01-01
AIMS To examine the effects of salbutamol and L-arginine, two compounds acting largely on the endothelium, and the endothelium-independent agent nitroglycerin on blood pressure, arterial compliance, cardiac function and vascular resistance. METHODS Continuous radial pulse wave analysis, whole-body impedance cardiography, and plethysmographic blood pressure from fingers in the supine position and during head-up tilt were recorded in nine healthy subjects. Data were captured before and after L-arginine (10 mg mg−1 min−1) or saline infusion, salbutamol (400 µg) or placebo inhalation, and sublingual nitroglycerin (0.25 mg) or placebo resoriblet. RESULTS The results of all measurements were comparable before drug administration. The effects of inhaled salbutamol were apparent in the supine position: systemic vascular resistance (−9.2 ± 2.6%) and augmentation index (−4.0 ± 1.5%) decreased, and heart rate (8.6 ± 2.5%) and cardiac output (8.8 ± 3.1%) increased. L-arginine had no clear effects on supine haemodynamics, but during head-up tilt blood pressure was moderately decreased and reduction in aortic reflection time prevented, indicating improved large arterial compliance. Nitroglycerin reduced supine vascular resistance (−6.7 ± 1.8%) and augmentation index (−7.4 ± 1.6%), and increased cardiac output (+9.2 ± 2.7%). During head-up tilt, nitroglycerin increased cardiac output (+10.6 ± 5.6%) and heart rate (+40 ± 7.5%), decreased vascular resistance (−7.8 ± 5.8%) and augmentation index (−18.7 ± 3.2%), and prevented the decrease in aortic reflection time. CONCLUSIONS Inhaled salbutamol predominantly changed supine haemodynamics, whereas the moderate effects of L-arginine were observed during the head-up tilt. In contrast, small doses of nitroglycerin induced major changes in haemodynamics both supine and during the head-up tilt. Altogether, these results emphasize the importance of haemodynamic measurements in both the supine and upright positions. PMID:19660000
Kazimierczak, Anna; Krzesiński, Paweł; Gielerak, Grzegorz; Uziębło-Życzkowska, Beata; Smurzyński, Paweł; Ryczek, Robert; Cwetsch, Andrzej; Skrobowski, Andrzej
2016-08-25
BACKGROUND Advanced heart failure (HF) is commonly accompanied by central sleep apnea (CSA) with Cheyne-Stokes respiration (CSR). The aim of this study was to evaluate the relationship between CSA/CSR and other clinical features of HF, with particular emphasis on cardiovascular hemodynamics. MATERIAL AND METHODS In 161 stable HF patients with left ventricular ejection fraction (LVEF) ≤45% (NYHA class I-III; mean LVEF 32.8%) the clinical evaluation included: LVEF; left and right ventricular end-diastolic diameter (LVDd, RVDd); ratio of early transmitral flow velocity to early diastolic septal mitral annulus velocity (E/e') assessed by echocardiography; stroke index (SI); heart rate (HR); cardiac index (CI); and systemic vascular resistance index (SVRI) assessed by impedance cardiography (ICG). The comparison was performed between 2 subgroups: one with moderate/severe CSA/CSR - CSR_ [+] (n=51), and one with mild or no CSA/CSR - CSR_ [-] (n=110). RESULTS CSR_ [+] patients presented more advanced NYHA class (p<0.001) and more frequently had permanent atrial fibrillation (p=0.018). Moreover, they had: lower LVEF (p<0.0001); higher LVDd (p<0.0001), RVDd (p<0.001), and E/e' (p<0.001); lower SI (p<0.001) and CI (p=0.009); and higher HR (p=0.044) and SVRI (p=0.016). The following predictors of CSR_ [+] were identified: NYHA class (OR=3.34 per class, p<0.001, which was the only independent predictor); atrial fibrillation (OR=2.29, p=0.019); RV enlargement (OR=2.75, p=0.005); LVEF<35% (OR=3.38, p=0.001); E/e' (OR=3.15; p=0.003); and SI<35 ml/m2 (OR=2.96, p=0.003). CONCLUSIONS Presence of CSA/CSR in HF is associated with NYHA class, atrial fibrillation and more advanced impairment of cardiovascular structure and hemodynamics. Patient functional state remains the main determinant of CSR.
Determinants of left ventricular diastolic dysfunction in hypertensive patients.
Nazário Leão, R; Marques da Silva, P; Marques Pocinho, R; Alves, M; Virella, D; Palma Dos Reis, R
2018-02-02
The progression of hypertensive heart disease leads to the left ventricular diastolic dysfunction (LVDD), which is associated with increased cardiovascular morbidity and mortality. The purpose of this analysis is to explore the determinants for LVDD in patients with hypertension. This is a secondary analysis of data of Impedance Cardiography in the Evaluation of Left Ventricular Diastolic Dysfunction in Patients with Arterial Hypertension (IMPEDDANS) Study. Mann-Whitney and Chi-square tests were used for univariable analysis. Multiple logistic regression was used to model for LVDD occurrence and discriminative capacity of the model assessed by the value of the area under the curve given by the receiver-operating characteristic curve. Older age (65 vs. 58 years, p<0.001), longer duration of hypertension (160 vs. 48 months, p<0.001), uncontrolled hypertension (59.8 vs. 15.9%, p<0.001), tobacco smoking (17.8 vs. 3.8%, p=0.016), higher systolic blood pressure (133 vs. 124mmHg, p=0.001) and slower heart rate (62 vs. 66bpm, p=0.023) were associated with LVDD. Multivariate model identified uncontrolled hypertension (AdjOR 36.90; 95% CI 7.94-171.58; p<0.001), smoking (AdjOR 6.66; 95% CI 1.63-27.26; p=0.008), eccentric hypertrophy (AdjOR 3.59; 95% CI 0.89-14.39; p=0.072), duration of hypertension (AdjOR 1.03; 95% CI 1.02-1.05; p<0.001) and concentric remodeling (AdjOR 0.19; 95% CI 0.04-0.93; p=0.041) as the more determinant for occurrence of LVDD. The discriminative capacity of the model was AUC=0.95 (95% CI 0.91-0.98). The occurrence of LVDD in hypertensive patients was strongly associated to long-lasting, uncontrolled hypertension, tobacco smoking, concentric remodeling and eccentric hypertrophy. Copyright © 2017 SEH-LELHA. Publicado por Elsevier España, S.L.U. All rights reserved.
Cerebral Hemodynamics During Exercise and Recovery in Heart Transplant Recipients.
Gayda, Mathieu; Desjardins, Audrey; Lapierre, Gabriel; Dupuy, Olivier; Fraser, Sarah; Bherer, Louis; Juneau, Martin; White, Michel; Gremeaux, Vincent; Labelle, Véronique; Nigam, Anil
2016-04-01
The aims of this work were (1) to compare cerebral oxygenation-perfusion (COP), central hemodynamics, and peak oxygen uptake (V˙o2peak) in heart transplant recipients (HTRs) vs age-matched healthy controls (AMHCs) during exercise and recovery and (2) to study the relationships between COP, central hemodynamics, and V˙o2peak in HTRs and AMHCs. Twenty-six HTRs (3 women) and 27 AMHCs (5 women) were recruited. Maximal cardiopulmonary function (gas exchange analysis), cardiac hemodynamics (impedance cardiography), and left frontal COP (near-infrared spectroscopy) were measured continuously during and after a maximal ergocycle (Ergoline 800S, Bitz, Germany) test. Compared with AMHCs, HTRs had lower V˙o2peak, maximal cardiac index (CImax), and maximal ventilatory variables (P < 0.05). COP was lower during exercise (oxyhemoglobin [ΔO2Hb], 50% and 75% of V˙O2peak, total hemoglobin [ΔtHb], 100% of V˙O2peak; P < 0.05), and recovery in HTRs (ΔO2Hb, minutes 2-5; ΔtHb, minutes 1-5; P < 0.05) compared with AMHCs. End-tidal pressure of CO2 was lower during exercise compared with that in AMHCs (P < 0.0001). In HTRs, CImax was positively correlated with exercise cerebral hemodynamics (R = 0.54-0.60; P < 0.01). In HTRs, COP was reduced during exercise and recovery compared with that in AMHCs, potentially because of a combination of blunted cerebral vasodilation by CO2, cerebrovascular dysfunction, reduced cardiac function, and medication. The impaired V˙O2peak observed in HTRs was mainly caused by reduced maximal ventilation and CI. In HTRs, COP is impaired and is correlated with cardiac function, potentially impacting cognitive function. Therefore, we need to study which interventions (eg, exercise training) are most effective for improving or normalizing (or both) COP during and after exercise in HTRs. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Thoracoscopic sympathectomy increases efferent cardiac vagal activity and baroreceptor sensitivity.
Bygstad, Elisabeth; Terkelsen, Astrid J; Pilegaard, Hans K; Hansen, John; Mølgaard, Henning; Hjortdal, Vibeke E
2013-09-01
Thoracoscopic sympathectomy at levels T2 or T2-T3 is a treatment for focal hyperhidrosis and facial blushing. These levels of the sympathetic trunk innervate the heart, and consequently, the procedure is reported to change the heart rate variability due to changes in efferent cardiac autonomic activity. Our objective was to investigate the effects of thoracoscopic sympathectomy on global autonomic control, including baroreceptor sensitivity. Eight patients (6 F, median age 28 years [range 20-58 years]) were exposed to the tilt-table test and cardiopulmonary exercise test before, and 3 months after, thoracoscopic sympathectomy. Eight healthy age-, gender- and BMI-matched controls were used as controls and underwent the same tests once. During tilt-table testing electrocardiogram, blood pressure, impedance cardiography and respiration were measured continuously, and efferent cardiac autonomic balance was estimated. The heart rate measured during orthostatic stress test was lowered after thoracoscopic sympathectomy (between-group; P = 0.01) due to a change in autonomic tone, with increased vagal (high-frequency power n.u.; P = 0.001), and reduced sympathetic efferent cardiac activity (low-frequency power n.u.; P < 0.001). Baroreceptor sensitivity measured during rest was increased (26 ± 13 vs 44 ± 19 ms/mmHg; P = 0.01), and diastolic blood pressure reduced after surgery (P = 0.01). The increases in systolic blood pressure and the sympathetic marker CCV-LF in response to orthostatic stress were higher before sympathectomy, with almost no increases post-surgically (condition × group interaction; P = 0.01 and P = 0.001, respectively). We found no change in post-procedure exercise capacity, although patients had a lower peak VO2 and maximal cardiac index than controls. Thoracoscopic sympathectomy changes the autonomic tone towards increased vagal activity; this is potentially cardioprotective. To our knowledge, this is the first study to show increased baroreceptor sensitivity after thoracoscopic sympathectomy.
Salvadego, Desy; Lazzer, Stefano; Marzorati, Mauro; Porcelli, Simone; Rejc, Enrico; Simunic, Bostjan; Pisot, Rado; di Prampero, Pietro Enrico; Grassi, Bruno
2011-12-01
A functional evaluation of skeletal muscle oxidative metabolism during dynamic knee extension (KE) incremental exercises was carried out following a 35-day bed rest (BR) (Valdoltra 2008 BR campaign). Nine young male volunteers (age: 23.5 ± 2.2 yr; mean ± SD) were evaluated. Pulmonary gas exchange, heart rate and cardiac output (by impedance cardiography), skeletal muscle (vastus lateralis) fractional O(2) extraction, and brain (frontal cortex) oxygenation (by near-infrared spectroscopy) were determined during incremental KE. Values at exhaustion were considered "peak". Peak heart rate (147 ± 18 beats/min before vs. 146 ± 17 beats/min after BR) and peak cardiac output (17.8 ± 3.3 l/min before vs. 16.1 ± 1.8 l/min after BR) were unaffected by BR. As expected, brain oxygenation did not decrease during KE. Peak O(2) uptake was lower after vs. before BR, both when expressed as liters per minute (0.99 ± 0.17 vs. 1.26 ± 0.27) and when normalized per unit of quadriceps muscle mass (46.5 ± 6.4 vs. 56.9 ± 11.0 ml·min(-1)·100 g(-1)). Skeletal muscle peak fractional O(2) extraction, expressed as a percentage of the maximal values obtained during a transient limb ischemia, was lower after (46.3 ± 12.1%) vs. before BR (66.5 ± 11.2%). After elimination, by the adopted exercise protocol, of constraints related to cardiovascular O(2) delivery, a decrease in peak O(2) uptake and muscle peak capacity of fractional O(2) extraction was found after 35 days of BR. These findings suggest a substantial impairment of oxidative function at the muscle level, "downstream" with respect to bulk blood flow to the exercising muscles, that is possibly at the level of blood flow distribution/O(2) utilization inside the muscle, peripheral O(2) diffusion, and intracellular oxidative metabolism.
Kubota, Satoshi; Endo, Yutaka; Kubota, Mitsue; Shigemasa, Tomohiko
2017-01-01
Background Downward shifts in blood volume with changing position generally cause tachycardic responses. Age-related decreases in vagal nerve activity could contribute to orthostatic hypotension in older individuals. Fowler’s position is a reclined position with the back between 30° and 60°, used to facilitate breathing, eating, and other routine daily activities in frail and elderly patients. Objective This study examined whether stroke volume (SV) was higher and heart rate (HR) lower in Fowler’s position with an upright upper trunk than in Fowler’s position with the whole trunk upright in both older and younger subjects, based on the assumption that lower HR would result from reduced sympathetic activation in older individuals. Methods We assessed hemodynamics and HR variability from electrocardiography, noninvasive arterial pressure and impedance cardiography in 11 younger male subjects (age range, 20–22 years) and 11 older male subjects (age range, 64–79 years), using three positions: supine, or Fowler’s positions with either 30° of lower trunk inclination and 60° of upper trunk inclination (UT60) or 60° of whole trunk inclination (WT60). Comparisons were then made between age groups and between positions. Results Reductions in SV and tachycardic response were smaller with UT60 than with WT60, in both younger and older subjects. In addition, reduced tachycardic response with upright upper trunk appeared attributable to decreased vagal withdrawal in younger subjects and to reduced sympathetic activation in older subjects. Conclusion Our findings indicate that an upright upper trunk during Fowler’s position allowed maintenance of SV and inhibited tachycardic response compared to an upright whole trunk regardless of age, although the autonomic mechanisms underlying tachycardic responses differed between younger and older adults. An upright upper trunk in Fowler’s position might help to reduce orthostatic stress and facilitate routine activities and conversation in frail patients. PMID:28408809
Kubota, Satoshi; Endo, Yutaka; Kubota, Mitsue; Shigemasa, Tomohiko
2017-01-01
Downward shifts in blood volume with changing position generally cause tachycardic responses. Age-related decreases in vagal nerve activity could contribute to orthostatic hypotension in older individuals. Fowler's position is a reclined position with the back between 30° and 60°, used to facilitate breathing, eating, and other routine daily activities in frail and elderly patients. This study examined whether stroke volume (SV) was higher and heart rate (HR) lower in Fowler's position with an upright upper trunk than in Fowler's position with the whole trunk upright in both older and younger subjects, based on the assumption that lower HR would result from reduced sympathetic activation in older individuals. We assessed hemodynamics and HR variability from electrocardiography, noninvasive arterial pressure and impedance cardiography in 11 younger male subjects (age range, 20-22 years) and 11 older male subjects (age range, 64-79 years), using three positions: supine, or Fowler's positions with either 30° of lower trunk inclination and 60° of upper trunk inclination (UT60) or 60° of whole trunk inclination (WT60). Comparisons were then made between age groups and between positions. Reductions in SV and tachycardic response were smaller with UT60 than with WT60, in both younger and older subjects. In addition, reduced tachycardic response with upright upper trunk appeared attributable to decreased vagal withdrawal in younger subjects and to reduced sympathetic activation in older subjects. Our findings indicate that an upright upper trunk during Fowler's position allowed maintenance of SV and inhibited tachycardic response compared to an upright whole trunk regardless of age, although the autonomic mechanisms underlying tachycardic responses differed between younger and older adults. An upright upper trunk in Fowler's position might help to reduce orthostatic stress and facilitate routine activities and conversation in frail patients.
Effects of Vestibular Loss on Orthostatic Responses to Tilts in the Pitch Plane
NASA Technical Reports Server (NTRS)
Wood, Scott J.; Serrador, Jorge M.; Black, F. Owen; Rupert,Angus H.; Schlegel, Todd T.
2004-01-01
The purpose of this study was to determine the extent to which vestibular loss might impair orthostatic responses to passive tilts in the pitch plane in human subjects. Data were obtained from six subjects having chronic bilateral vestibular loss and six healthy individuals matched for age, gender, and body mass index. Vestibular loss was assessed with a comprehensive battery including dynamic posturography, vestibulo-ocular and optokinetic reflexes, vestibular evoked myogenic potentials, and ocular counterrolling. Head up tilt tests were conducted using a motorized two-axis table that allowed subjects to be tilted in the pitch plane from either a supine or prone body orientation at a slow rate (8 deg/s). The sessions consisted of three tilts, each consisting of20 min rest in a horizontal position, tilt to 80 deg upright for 10 min, and then return to the horizontal position for 5 min. The tilts were performed in darkness (supine and prone) or in light (supine only). Background music was used to mask auditory orientation cues. Autonomic measurements included beat-to-beat recordings of blood pressure (Finapres), heart rate (ECG), cerebral blood flow velocity in the middle cerebral artery (transcranial Doppler), end tidal CO2, respiratory rate and volume (Respritrace), and stroke volume (impedance cardiography). For both patients and control subjects, cerebral blood flow appeared to exhibit the most rapid adjustment following transient changes in posture. Outside of a greater cerebral hypoperfusion in patients during the later stages of tilt, responses did not differ dramatically between the vestibular loss and control subjects, or between tilts performed in light and dark room conditions. Thus, with the 'exception of cerebrovascular regulation, we conclude that orthostatic responses during slow postural tilts are not substantially impaired in humans following chronic loss of vestibular function, a result that might reflect compensation by nonvisual graviceptor inputs (e.g., somatosensory) or other circulatory reflex mechanisms.
Beeler, Remo; Schoenenberger, Andreas W; Bauer, Peter; Kobza, Richard; Bergner, Michael; Mueller, Xavier; Schlaepfer, Reinhard; Zuber, Michel; Erne, Susanne; Erne, Paul
2014-03-01
Device-based pacing-induced diaphragmatic stimulation (PIDS) may have therapeutic potential for chronic heart failure (HF) patients. We studied the effects of PIDS on cardiac function and functional outcomes. In 24 chronic HF patients with CRT, an additional electrode was attached to the left diaphragm. Randomized into two groups, patients received the following PIDS modes for 3 weeks in a different sequence: (i) PIDS off (control group); (ii) PIDS 0 ms mode (PIDS simultaneously with ventricular CRT pulse); or (iii) PIDS optimized mode (PIDS with optimized delay to ventricular CRT pulse). For PIDS optimization, acoustic cardiography was used. Effects of each PIDS mode on dyspnoea, power during exercise testing, and LVEF were assessed. Dyspnoea improved with the PIDS 0 ms mode (P = 0.057) and the PIDS optimized mode (P = 0.034) as compared with the control group. Maximal power increased from median 100.5 W in the control group to 104.0 W in the PIDS 0 ms mode (P = 0.092) and 109.5 W in the PIDS optimized mode (P = 0.022). Median LVEF was 33.5% in the control group, 33.0% in the PIDS 0 ms mode, and 37.0% in the PIDS optimized mode (P = 0.763 and P = 0.009 as compared with the control group, respectively). PIDS was asymptomatic in all patients. PIDS improves dyspnoea, working capacity, and LVEF in chronic HF patients over a 3 week period in addition to CRT. This pilot study demonstrates proof of principle of an innovative technology which should be confirmed in a larger sample. NCT00769678. © 2013 The Authors. European Journal of Heart Failure © 2013 European Society of Cardiology.
NASA Astrophysics Data System (ADS)
Irimia, Andrei; Swinney, Kenneth R.; Wikswo, John P.
2009-05-01
In this paper, we clearly demonstrate that the electric potential and the magnetic field can contain different information about current sources in three-dimensional conducting media. Expressions for the magnetic fields of electric dipole and quadrupole current sources immersed in an infinite conducting medium are derived, and it is shown that two different point dipole distributions that are electrically equivalent have different magnetic fields. Although measurements of the electric potential are not sufficient to determine uniquely the characteristics of a quadrupolar source, the radial component of the magnetic field can supply the additional information needed to resolve these ambiguities and to determine uniquely the configuration of dipoles required to specify the electric quadrupoles. We demonstrate how the process can be extended to even higher-order terms in an electrically silent series of magnetic multipoles. In the context of a spherical brain source model, it has been mathematically demonstrated that the part of the neuronal current generating the electric potential lives in the orthogonal complement of the part of the current generating the magnetic potential. This implies a mathematical relationship of complementarity between electroencephalography and magnetoencephalography, although the theoretical result in question does not apply to the nonspherical case [G. Dassios, Math. Med. Biol. 25, 133 (2008)]. Our results have important practical applications in cases where electrically silent sources that generate measurable magnetic fields are of interest. Moreover, electrically silent, magnetically active moments of higher order can be useful when cancellation due to superposition of fields can occur, since this situation leads to a substantial reduction in the measurable amplitude of the signal. In this context, information derived from magnetic recordings of electrically silent, magnetically active multipoles can supplement electrical recordings for the purpose of studying the physiology of the brain. Magnetic fields of the electric multipole sources in a conducting medium surrounded by an insulating spherical shell are also presented and the relevance of this calculation to cardiographic and encephalographic experimentation is discussed.
Ashouri, Hazar; Inan, Omer T
2017-06-15
Seismocardiography (SCG), the measurement of the local chest vibrations due to the movements of blood and the heart, is a non-invasive technique for assessing myocardial contractility via the pre-ejection period (PEP). Recently, SCG-based extraction of PEP has been shown to be an effective means of classifying decompensated from compensated heart failure patients, and thus can be potentially used for monitoring such patients at home. Accurate extraction of PEP from SCG signals hinges on lab-based population data (i.e., regression curves) linking particular time-domain features of the SCG signal to corresponding features from reference standard bulky instruments such as impedance cardiography (ICG). Such regression curves, in the case of SCG, have always been estimated based on the "ideal" positioning of the SCG sensor on the chest. However, in settings such as the home where users may position the SCG measurement hardware on the chest without supervision, it is likely that the sensor will not always be placed exactly on this "ideal" location on the sternum, but rather on other positions on the chest as well. In this study, we show for the first time that the regression curve for estimating PEP from SCG signals differs significantly as the position of the sensor changes. We further devise a method to automatically detect when the sensor is placed in any position other than the desired one in order to avoid inaccurate systolic time interval estimation. Our classification algorithm for this purpose resulted in 0.83 precision and 0.82 recall when classifying whether the sensor is placed in the desired position or not. The classifier was tested with heartbeats taken both at rest, and also during exercise recovery to ensure that waveform changes due to positioning could be accurately discriminated from those due to physiological effects.
Echocardiography as an indication of continuous-time cardiac quiescence
NASA Astrophysics Data System (ADS)
Wick, C. A.; Auffermann, W. F.; Shah, A. J.; Inan, O. T.; Bhatti, P. T.; Tridandapani, S.
2016-07-01
Cardiac computed tomography (CT) angiography using prospective gating requires that data be acquired during intervals of minimal cardiac motion to obtain diagnostic images of the coronary vessels free of motion artifacts. This work is intended to assess B-mode echocardiography as a continuous-time indication of these quiescent periods to determine if echocardiography can be used as a cost-efficient, non-ionizing modality to develop new prospective gating techniques for cardiac CT. These new prospective gating approaches will not be based on echocardiography itself but on CT-compatible modalities derived from the mechanics of the heart (e.g. seismocardiography and impedance cardiography), unlike the current standard electrocardiogram. To this end, echocardiography and retrospectively-gated CT data were obtained from ten patients with varied cardiac conditions. CT reconstructions were made throughout the cardiac cycle. Motion of the interventricular septum (IVS) was calculated from both echocardiography and CT reconstructions using correlation-based, deviation techniques. The IVS was chosen because it (1) is visible in echocardiography images, whereas the coronary vessels generally are not, and (2) has been shown to be a suitable indicator of cardiac quiescence. Quiescent phases were calculated as the minima of IVS motion and CT volumes were reconstructed for these phases. The diagnostic quality of the CT reconstructions from phases calculated from echocardiography and CT data was graded on a four-point Likert scale by a board-certified radiologist fellowship-trained in cardiothoracic radiology. Using a Wilcoxon signed-rank test, no significant difference in the diagnostic quality of the coronary vessels was found between CT volumes reconstructed from echocardiography- and CT-selected phases. Additionally, there was a correlation of 0.956 between the echocardiography- and CT-selected phases. This initial work suggests that B-mode echocardiography can be used as a tool to develop CT-compatible gating techniques based on modalities derived from cardiac mechanics rather than relying on the ECG alone.
Anyfanti, Panagiota; Triantafyllou, Areti; Gkaliagkousi, Eugenia; Triantafyllou, Georgios; Koletsos, Nikolaos; Chatzimichailidou, Sophia; Panagopoulos, Panagiotis; Botis, Ioannis; Aslanidis, Spyros; Douma, Stella
2017-06-01
Cardiac involvement is common in rheumatoid arthritis. Subendocardial viability ratio (SEVR) is a non-invasive measure of microvascular coronary perfusion, yet it remains unclear whether it is affected in rheumatoid arthritis patients. We additionally sought predictors of SEVR in rheumatoid arthritis among a wide range of disease-related parameters, cardiac and hemodynamic factors, and markers of atherosclerosis, arteriosclerosis, and endothelial dysfunction. SEVR was estimated in rheumatoid arthritis patients and healthy controls by applanation tonometry, which was also used to evaluate arterial stiffness (pulse wave velocity and augmentation index). In the rheumatoid arthritis group, carotid intima-media thickness (cIMT) was additionally estimated by ultrasound, cardiac and hemodynamic parameters by impedance cardiography, and endothelial dysfunction by measurement of asymmetric dimethylarginine (ADMA). In a total of 122 participants, SEVR was lower among 91 patients with rheumatoid arthritis compared to 31 controls (141.4 ± 21.9 vs 153.1 ± 18.7%, p = 0.009) and remained so among 29 rheumatoid arthritis patients without hypertension, diabetes, or cardiovascular diseases, compared to the control group (139.7 ± 21.7 vs 153.1 ± 18.7%, p = 0.013). SEVR did not significantly correlate with arterial stiffness, cIMT, ADMA, or disease-related parameters. Multivariate analysis revealed gender (p = 0.007), blood pressure (p = 0.028), heart rate (p = 0.025), cholesterol levels (p = 0.008), cardiac index (p < 0.001) and left ventricular ejection time (p = 0.004) as independent predictors of SEVR among patients with rheumatoid arthritis. Patients with rheumatoid arthritis exhibit lower values of SEVR compared to healthy individuals. Cardiac and hemodynamic parameters, rather than functional indices of endothelial and macrovascular dysfunction, may be useful as predictors of myocardial perfusion in rheumatoid arthritis.
Kazimierczak, Anna; Krzesiński, Paweł; Gielerak, Grzegorz; Uziebło-Życzkowska, Beata; Smurzyński, Paweł; Ryczek, Robert; Cwetsch, Andrzej; Skrobowski, Andrzej
2016-01-01
Background Advanced heart failure (HF) is commonly accompanied by central sleep apnea (CSA) with Cheyne-Stokes respiration (CSR). The aim of this study was to evaluate the relationship between CSA/CSR and other clinical features of HF, with particular emphasis on cardiovascular hemodynamics. Material/Methods In 161 stable HF patients with left ventricular ejection fraction (LVEF) ≤45% (NYHA class I–III; mean LVEF 32.8%) the clinical evaluation included: LVEF; left and right ventricular end-diastolic diameter (LVDd, RVDd); ratio of early transmitral flow velocity to early diastolic septal mitral annulus velocity (E/e’) assessed by echocardiography; stroke index (SI); heart rate (HR); cardiac index (CI); and systemic vascular resistance index (SVRI) assessed by impedance cardiography (ICG). The comparison was performed between 2 subgroups: one with moderate/severe CSA/CSR - CSR_ [+] (n=51), and one with mild or no CSA/CSR – CSR_ [−] (n=110). Results CSR_ [+] patients presented more advanced NYHA class (p<0.001) and more frequently had permanent atrial fibrillation (p=0.018). Moreover, they had: lower LVEF (p<0.0001); higher LVDd (p<0.0001), RVDd (p<0.001), and E/e’ (p<0.001); lower SI (p<0.001) and CI (p=0.009); and higher HR (p=0.044) and SVRI (p=0.016). The following predictors of CSR_ [+] were identified: NYHA class (OR=3.34 per class, p<0.001, which was the only independent predictor); atrial fibrillation (OR=2.29, p=0.019); RV enlargement (OR=2.75, p=0.005); LVEF<35% (OR=3.38, p=0.001); E/e’ (OR=3.15; p=0.003); and SI<35 ml/m2 (OR=2.96, p=0.003). Conclusions Presence of CSA/CSR in HF is associated with NYHA class, atrial fibrillation and more advanced impairment of cardiovascular structure and hemodynamics. Patient functional state remains the main determinant of CSR. PMID:27558771
NASA Technical Reports Server (NTRS)
Doerr, Donald F.; Ratliff, Duane A.; Sithole, Joseph; Convertino, Victor A.
2005-01-01
Background: The real time, beat-by-beat, non-invasive determination of stroke volume (SV) is an important parameter in many aerospace related physiologic protocols. In this study, we compared simultaneous estimates of SV calculated from peripheral pulse waveforms with a more conventional non-invasive technique. Methods: Using a prospective, randomized blinded protocol, ten males and nine females completed 12-mm tilt table protocols. The relative change (%(Delta)) in beat-to-beat SV was estimated non-invasively from changes in pulse waveforms measured by application of infrared finger photoplethysmography (IFP) with a Portapres(Registered TradeMark) blood pressure monitoring device and by thoracic impedance cardiography (TIC). The %(Delta) SV values were calculated from continuous SV measurements in the supine posture and over the first 10 s (T1), second 10 s (T2), and 3.5 minutes (T3) of 80deg head-up tilt (HUT). Results: The average %(Delta) SV measured by IFP at T1 (-11.7 +/- 3.7 %) was statistically less (P <0.02) than the average %(Delta) SV measured by TIC at T1 (-21.7 +/- 3.1 %), while the average %(Delta) SV measured by 1FF at T2 (-16.2 +/- 3.9 %) and T3 (-19.1 +/- 3.8 %) were not statistically distinguishable (P > or = 0.322) than the average %(Delta) SV measured by TIC at T2 (-21.8 +/- 2.5 %), and T3 (-22.6 +/- 2.9 %). Correlation coefficients (r(sup 2)) between IFP and TIC were 0.117 (T1), 0.387 (T2), and 0.7 18 (T3). Conclusion: IFP provides beat-to-beat (real time) assessment of %(Delta) SV after 20 sec of transition to an orthostatic challenge that is comparable to the commonly accepted TIC. Our data support the notion that IFP technology which has flown during space missions can be used to accurately assess physiological status and countermeasure effectiveness for orth static problems that may arise in astronauts after space flight. While the peripherally measured IFP response is slightly delayed, the ease of implementing this monitor in the field is advantageous.
Fiskum, Charlotte; Andersen, Tonje G.; Bornas, Xavier; Aslaksen, Per M.; Flaten, Magne A.; Jacobsen, Karl
2018-01-01
Background: Internalizing psychopathology and dysregulated negative affect are characterized by dysregulation in the autonomic nervous system and reduced heart rate variability (HRV) due to increases in sympathetic activity alongside reduced vagal tone. The neurovisceral system is however, a complex nonlinear system, and nonlinear indices related to psychopathology are so far less studied in children. Essential nonlinear properties of a system can be found in two main domains: the informational domain and the invariant domain. sample entropy (SampEn) is a much-used method from the informational domain, while detrended fluctuation analysis (DFA) represents a widely-used method from the invariant domain. To see if nonlinear HRV can provide information beyond linear indices of autonomic activation, this study investigated SampEn and DFA as discriminators of internalizing psychopathology and negative affect alongside measures of vagally-mediated HRV and sympathetic activation. Material and Methods: Thirty-Two children with internalizing difficulties and 25 healthy controls (aged 9–13) were assessed with the Child Behavior Checklist and the Early Adolescent Temperament Questionnaire, Revised, giving an estimate of internalizing psychopathology, negative affect and effortful control, a protective factor against psychopathology. Five minute electrocardiogram and impedance cardiography recordings were collected during a resting baseline, giving estimates of SampEn, DFA short-term scaling exponent α1, root mean square of successive differences (RMSSD), and pre-ejection period (PEP). Between-group differences and correlations were assessed with parametric and non-parametric tests, and the relationships between cardiac variables, psychopathology and negative affect were assessed using generalized linear modeling. Results: SampEn and DFA were not significantly different between the groups. SampEn was weakly negatively related to heart rate (HR) in the controls, while DFA was moderately negatively related to RMSSD in both groups, and moderately positively related to HR in the clinical sample. SampEn was significantly associated with internalizing psychopathology and negative affect. DFA was significantly related to internalizing psychopathology. Conclusions: Higher invariant self-similarity was linked to less psychopathology. Higher informational entropy was related to less psychopathology and less negative affect, and may provide an index of the organizational flexibility of the neurovisceral system. PMID:29875679
Fiskum, Charlotte; Andersen, Tonje G; Bornas, Xavier; Aslaksen, Per M; Flaten, Magne A; Jacobsen, Karl
2018-01-01
Background: Internalizing psychopathology and dysregulated negative affect are characterized by dysregulation in the autonomic nervous system and reduced heart rate variability (HRV) due to increases in sympathetic activity alongside reduced vagal tone. The neurovisceral system is however, a complex nonlinear system, and nonlinear indices related to psychopathology are so far less studied in children. Essential nonlinear properties of a system can be found in two main domains: the informational domain and the invariant domain. sample entropy (SampEn) is a much-used method from the informational domain, while detrended fluctuation analysis (DFA) represents a widely-used method from the invariant domain. To see if nonlinear HRV can provide information beyond linear indices of autonomic activation, this study investigated SampEn and DFA as discriminators of internalizing psychopathology and negative affect alongside measures of vagally-mediated HRV and sympathetic activation. Material and Methods: Thirty-Two children with internalizing difficulties and 25 healthy controls (aged 9-13) were assessed with the Child Behavior Checklist and the Early Adolescent Temperament Questionnaire, Revised, giving an estimate of internalizing psychopathology, negative affect and effortful control, a protective factor against psychopathology. Five minute electrocardiogram and impedance cardiography recordings were collected during a resting baseline, giving estimates of SampEn, DFA short-term scaling exponent α 1 , root mean square of successive differences (RMSSD), and pre-ejection period (PEP). Between-group differences and correlations were assessed with parametric and non-parametric tests, and the relationships between cardiac variables, psychopathology and negative affect were assessed using generalized linear modeling. Results: SampEn and DFA were not significantly different between the groups. SampEn was weakly negatively related to heart rate (HR) in the controls, while DFA was moderately negatively related to RMSSD in both groups, and moderately positively related to HR in the clinical sample. SampEn was significantly associated with internalizing psychopathology and negative affect. DFA was significantly related to internalizing psychopathology. Conclusions: Higher invariant self-similarity was linked to less psychopathology. Higher informational entropy was related to less psychopathology and less negative affect, and may provide an index of the organizational flexibility of the neurovisceral system.
Niedzwiecki, Pawel; Naskret, Dariusz; Pilacinski, Stanislaw; Pempera, Maciej; Uruska, Aleksandra; Adamska, Anna; Zozulinska-Ziolkiewicz, Dorota
2017-06-01
The aim of this study was to assess the hemodynamic parameters analyzed in bioimpedance cardiography during maximal exercise in patients with type 1 diabetes differing in insulin resistance. The study group consisted of 40 men with type 1 diabetes. Tissue sensitivity to insulin was assessed on the basis of the glucose disposal rate (GDR) analyzed during hyperinsulinemic-euglycemic clamp. Patients were divided into groups with GDR <4.5 mg/kg/min (G1 group-lower insulin sensitivity) and GDR ≥4.5 mg/kg/min (G2 group-higher insulin sensitivity). During the exercise test, the heart rate, systolic volume, cardiac output, cardiac index were measured by the impedance meter (PhysioFlow). Compared with the G2 group, the G1 group had a lower cardiac output (CO): during exercise 8.6 (IQR 7.7-10.0) versus 12.8 (IQR 10.8-13.7) L/min; P < 0.0001, at the maximal effort 13.1 (IQR 12.2-16.7) versus 18.6 (IQR 16.9-20.2) L/min; P = 0.001, and during observation after exercise 8.4 (IQR 6.3-9.6) versus 11.9 (IQR 10.1-13.1) L/min; P < 0.0001. We noticed a positive correlation of GDR and cardiac output: during the exercise test (r = 0.63, P = 0.0002), at the maximal effort (Rs 0.56, P = 0.001), and during observation after the exercise test (r = 0.72, P < 0.0001). In multivariate logistic regression, cardiac output during exercise and during observation was associated with high GDR, regardless of the age and duration of diabetes [OR: 1.98 (95% CI 1.10-3.56), P = 0.02 and OR: 1.91 (95% CI 1.05-3.48), P = 0.03; respectively]. In nonobese subjects with type 1 diabetes, with good metabolic control, insulin resistance is associated with cardiac hemodynamic parameters assessed during and after exercise. The higher the insulin resistance the lower the cardiac output during maximal exercise in men with type 1 diabetes.
Krzesinski, P; Gielerak, G; Stanczyk, A; Piotrowicz, K; Skrobowski, A
2015-06-01
Impedance cardiography (ICG) revealed to be useful in tailoring antihypertensive therapy to the patient's individual hemodynamic profile but little is known who benefits more from such therapeutic approach. The aim of this study was to estimate the effectiveness of ICG-guided antihypertensive therapy in 12-weeks observation with respect to baseline blood pressure (BP). This analysis involved 272 patients with untreated AH, recruited in two randomized, prospective and controlled trials (www.nauka-polska.pl: ID227062 and ClinicalTrials.gov: NCT01996085). After baseline evaluation including office blood pressure measurement (OBPM: OSBP, ODBP, OMBP) and ambulatory blood pressure monitoring (ABPM: 24-mean_SBP, 24-mean_DBP) the subjects were randomly assigned to groups of: [GE] empiric and [HD] ICG-guided antihypertensive therapy. The effectiveness of ICG-guided therapy was evaluated after 12 weeks in subgroups derived from median of OMBP (110 mmHg) of: higher (n = 120) and lower baseline OMBP (n = 121). The comparative analysis included absolute change of BP (d_OSBP, d_ODBP, d_24-mean_SBP, d_24-mean_DBP) and percentage of patients with change of BP equal or higher than 10 mmHg (d10_OSBP, d10_ODBP, d10_24-mean_SBP, d10_24-mean_DBP). In the whole study group the BP reduction in HD group was higher than in GE group: d_OSBP (18.3 vs. 14.3 mmHg; p = 0.011), d_ODBP (11.9 vs. 8.5 mmHg; p = 0.011), d_24-mean SBP (15.9 vs. 11.6 mmHg; p = 0.011) and d_24-mean SBP (10.4 vs. 8.9 mmHg; p = 0.147). However, the effect of ICG-guided therapy was significantly more pronounced in subjects with higher baseline OMBP - Table.(Figure is included in full-text article.) : The ICG-guided therapy effects with increased BP reduction in patients with AH, especially those with higher baseline BP. The patients with advanced AH can benefit more from individual these therapeutic approach.
LBNP as useful tool for pilot candidates selection to the Polish Air Force: a preliminary study.
Romuald, M; Mariusz, Z; Artur, D; Krzysztof, R
2001-07-01
Candidates to the Polish Air Force are to fulfill strict medical conditions. Every candidate, wanting to become a fighter pilot or not, has to pass a rigorous centrifuge examination. This is a costly and especially stressful process for the candidates, as first-timers. This article explores possibility for different approach to candidates fitness to fly assessment. 14 candidates (21-22 yrs old) were subjected to a regular GOR centrifuge profile (0.1 G/s; up to +7.0 Gz; unprotected) and to lower body negative pressure (LBNP) examination (2 min. rest period followed by 3 min. at -40 mm Hg; supine position). Both, centrifuge and LBNP examinations were carried out the same day, with about 1 hour gap between them. ECG and impedance cardiography (ICG) were being recorded during both tests. The following parameters were calculated: HR and QZ (time between ventricular depolarization [beginning of the Q wave in ECG] and local maximum of the first derivative [dZ/dt] in ICG). QZ was considered to be an effective measure of dynamic heart function. +Gz tolerance for the group was +5.94 +/- 0.98 Gz. Correlation between +Gz tolerance and QZ values during LBNP test (-40 mm Hg) for all subjects was equal to r=0.6. Correlation between sets of parameters (canonical analysis) for LBNP and centrifuge was equal to r=0.78. Both results were statistically insignificant (p<0.09). Baseline HR values were 121 +/- 19 bpm and 75 +/- 12 bpm, and maximal HR values were 172 +/- 21 bpm and 81 +/- 13 bpm, respectively for centrifuge and LBNP. For both, baseline and maximal HR during LBNP and G exposure canonical correlation was equal to r=0.72. The results were statistically not significant, however. Centrifuge examination is much more stressful than LBNP test. This could have implication on the objective results of centrifuge test. The results may suggest that LBNP test could be a used in pilot candidates selection, especially those presenting high baseline HR values.
Network design for telemedicine--e-health using satellite technology.
Graschew, Georgi; Roelofs, Theo A; Rakowsky, Stefan; Schlag, Peter M
2008-01-01
Over the last decade various international Information and Communications Technology networks have been created for a global access to high-level medical care. OP 2000 has designed and validated the high-end interactive video communication system WinVicos especially for telemedical applications, training of the physician in a distributed environment, teleconsultation and second opinion. WinVicos is operated on a workstation (WoTeSa) using standard hardware components and offers a superior image quality at a moderate transmission bandwidth of up to 2 Mbps. WoTeSa / WinVicos have been applied for IP-based communication in different satellite-based telemedical networks. In the DELTASS-project a disaster scenario was analysed and an appropriate telecommunication system for effective rescue measures for the victims was set up and evaluated. In the MEDASHIP project an integrated system for telemedical services (teleconsultation, teleelectro-cardiography, telesonography) on board of cruise ships and ferries has been set up. EMISPHER offers an equal access for most of the countries of the Euro-Mediterranean area to on-line services for health care in the required quality of service. E-learning applications, real-time telemedicine and shared management of medical assistance have been realized. The innovative developments in ICT with the aim of realizing a ubiquitous access to medical resources for everyone at any time and anywhere (u-Health) bear the risk of creating and amplifying a digital divide in the world. Therefore we have analyzed how the objective needs of the heterogeneous partners can be joined with the result that there is a need for real integration of the various platforms and services. A virtual combination of applications serves as the basic idea for the Virtual Hospital. The development of virtual hospitals and digital medicine helps to bridge the digital divide between different regions of the world and enables equal access to high-level medical care. Pre-operative planning, intra-operative navigation and minimally-invasive surgery require a digital and virtual environment supporting the perception of the physician. As data and computing resources in a virtual hospital are distributed over many sites the concept of the Grid should be integrated with other communication networks and platforms.
Stidsen, Jacob Volmer; Nielsen, Jens Steen; Henriksen, Jan Erik; Friborg, Søren Gunnar; Olesen, Thomas Bastholm; Olsen, Michael Hecht; Beck-Nielsen, Henning
2017-01-01
Introduction We present the protocol for a multifactorial intervention study designed to test whether individualised treatment, based on pathophysiological phenotyping and individualised treatment goals, improves type 2 diabetes (T2D) outcomes. Methods and analysis We will conduct a prospective controlled multicentre open-label intervention study, drawing on the longitudinal cohort of the Danish Centre for Strategic Research in Type 2 Diabetes (DD2). New clinically diagnosed patients with T2D in the intervention group will be assigned to receive individualised treatment by their general practitioner. Intervention patients will be compared with a matched control cohort of DD2 patients receiving routine clinical care. Among intervention patients, we will first do pathophysiological phenotyping to classify patients into WHO-defined T2D or other specific types of diabetes (monogenic diabetes, secondary diabetes etc). Patients with WHO-defined T2D will then be further subcharacterised by their beta-cell function (BCF) and insulin sensitivity (IS), using the revised homeostatic assessment model, as having either insulinopaenic T2D (high IS and low BCF), classical T2D (low IS and low BCF) or hyperinsulinaemic T2D (low IS and high BCF). For each subtype, a specific treatment algorithm will target the primary pathophysiological defect. Similarly, antihypertensive treatment will be targeted at the specific underlying pathophysiology, characterised by impedance cardiography (relative importance of vascular resistance, intravascular volume and cardiac inotropy). All treatment goals will be based on individual patient assessment of expected positive versus adverse effects. Web-based and face-to-face individualised lifestyle intervention will also be implemented to empower patients to make a sustainable improvement in daily physical activity and to change to a low-carbohydrate diet. Ethics and dissemination The study will use well-known pharmacological agents according to their labels; patient safety is therefore considered high. Study results will be published in international peer-reviewed journals. Trial registration number NCT02015130; Pre-results. PMID:29229652
Shin, Jae-Young; Lee, Jun-Hwan; Ku, Boncho; Bae, Jang Han; un, Min-Ho; Kim, Jaeuk U.; Kim, Tae-Hun
2016-01-01
Introduction: This study aims to investigate the effects of acupuncture stimulation on the radial artery’s pressure pulse wave, along with various hemodynamic parameters, and to explore the possible underlying mechanism of pulse diagnosis in healthy participants in their twenties. Methods and analysis: This study is a prospective, single-arm, exploratory clinical study. A total of 25 healthy participants, without regard to gender, in their twenties will be recruited by physicians. Written informed consent will be obtained from all participants. The participants will receive acupuncture once at ST36 on both sides. The radial arterial pulse waves will be measured on the left arm of the subjects by using an applicable pulse tonometric device (KIOM-PAS). On the right arm (appearing twice), electrocardiogram (ECG), photoplethysmogram (PPG), respiration and cardiac output (CO) signals, will be measured using a physiological data acquisition system (Biopac module), while the velocity of blood flow, and the diameter and the depth of the blood vessel will be measured using an ultrasonogram machine on the right arm (appearing twice). All measurements will be conducted before, during, and after acupuncture. The primary outcome will be the spectral energy at high frequencies above 10 Hz (SE10-30Hz) calculated from the KIOM-PAS device signal. Secondary outcomes will be various variables obtained from the KIOM-PAS device, ECG, PPG, impedance cardiography modules, and an ultrasonogram machine. Discussion: The results of this trial will provide information regarding the physiological and the hemodynamic mechanisms underlying acupuncture stimulation and clinical evidence for the influence of acupuncture on the pressure pulse wave in the radial artery. Ethics and dissemination: This study was approved by the Institutional Review Board (IRB) of Kyung Hee University’s Oriental Medical Center, Seoul, Korea (KOMCIRB-150818-HR-030). The study findings will be published in peer-reviewed journals and presented at national and international conferences. Trial registration number: This trial was registered with the Clinical Research Information Service (CRIS) at the Korea National Institute of Health (NIH), Republic of Korea (KCT0001663), which is a registry in the World Health Organization’s (WHO’s) Registry Network. PMID:27695628
Takahashi, T; Okada, A; Saitoh, T; Hayano, J; Miyamoto, Y
2000-02-01
Cardiovascular responses were examined in seven healthy male subjects during 10 min of recovery in the upright or supine position following 5 min of upright cycle exercise at 80% peak oxygen uptake. An initial rapid decrease in heart rate (fc) during the early phase of recovery followed by much slower decrease was observed for both the upright and supine positions. The average fc at the 10th min of recovery was significantly lower (P < 0.05) in the supine position than in the upright position, while they were both significantly greater than the corresponding pre-exercise levels (each P < 0.05). Accordingly, the amplitude of the high frequency (HF) component of R-R interval variability (by spectrum analysis) in both positions was reduced with a decrease in mean R-R interval, the relationship being expressed by a regression line--mean R-R interval = 0.006 x HF amplitude + 0.570 (r = 0.905, n = 28, P < 0.001). These results would suggest that the slower reduction in fc following the initial rapid reduction in both positions is partly attributable to a retardation in the restoration of the activity of the cardiac parasympathetic nervous system. Post-exercise upright stroke volume (SV, by impedance cardiography) decreased gradually to just below the pre-exercise level, whereas post-exercise supine SV increased markedly to a level similar to that at rest before exercise. The resultant cardiac output (Qc) and the total peripheral vascular resistance (TPR) in the upright and supine positions returned gradually to their respective pre-exercise levels in the corresponding positions. At the 10th min of recovery, both average SV and Qc were significantly greater (each P < 0.005) in the supine than in the upright position, while average TPR was significantly lower (P < 0.05) in the supine than in the upright position. In contrast, immediately after exercise, mean blood pressure dropped markedly in both the supine and upright positions, and their levels at the 10th min of recovery were similar. Therefore we concluded that arterial blood pressure is maintained relatively constant through various compensatory mechanisms associated with fc, SV, Qc, and TPR during rest and recovery in different body positions.
Comparison of cardiovascular function during the early hours of bed rest and space flight
NASA Technical Reports Server (NTRS)
Lathers, C. M.; Charles, J. B.
1994-01-01
This paper reviews the cardiovascular responses of six healthy male subjects to 6 hours in a 5 degrees head-down bed rest model of weightlessness, and compares these responses to those obtained when subjects were positioned in head-up tilts of 10 degrees, 20 degrees, and 42 degrees, simulating 1/6, 1/3, and 2/3 G, respectively. Thoracic fluid index, cardiac output, stroke volume, and peak flow were measured using impedance cardiography. Cardiac dimensions and volumes were determined from two-dimensional guided M-mode echocardiograms in the left lateral decubitus position at 0, 2, 4, and 6 hours. Cardiovascular response to a stand test were compared before and after bed rest. The impedance values were related to tilt angle for the first 2 hours of tilt; however, after 3 hours, at all four angles, values began to converge, indicating that cardiovascular homeostatic mechanisms seek a common adapted state, regardless of effective gravity level (tilt angle) up to 2/3 G. Echocardiography revealed that left ventricular end-diastolic and end-systolic volume, stroke volume, ejection fraction, heart rate, and cardiac output had returned to control values by hour 6 for all tilt angles. The lack of a significant immediate change in left ventricular end-diastolic volume, despite decrements in stroke volume (P < .05) and heart rate (not significant), indicates that multiple factors may play a role in the adaptation to simulated hypogravity. The echocardiography data indicated that no angle of tilt, whether head-down or head-up for 4 to 6 hours, mimicked exactly the changes in cardiovascular function recorded after 4 to 6 hours of space flight. Changes in left ventricular end-diastolic volume during space flight and tilt may be similar, but follow a different time course. Nevertheless, head-down tilt at 5 degrees for 6 hours mimics some (stroke volume, systolic and diastolic blood pressure, mean arterial blood pressure, and total resistance), but not all, of the changes occurring in an equivalent time of space flight. The magnitude of the change in the mean heart rate response to standing was greater after six hours of tilt at -5 degrees or 10 degrees. Thus, results from the stand test after 6 hours of bed rest at -5 degrees and 10 degrees, but not at 20 degrees or 42 degrees, are similar to those obtained after space flight.
Youssef, Marylen; Ghassemi, Azadeh; Carvajal Gonczi, Catalina Marysol; Kugathasan, Thiffya Arabi; Kilgour, Robert D; Darlington, Peter J
2018-06-01
The cold pressor test (CPT) involves acute hand or foot exposure to cold water. CPT hyper-responders have unique traits, including risk of hypertension and a greater vasoconstrictor reserve and g force tolerance compared to hypo-responders. The purpose of this study was to uncover differences in cardiovascular and sympathetic biomarkers between responder types. Healthy volunteers (N = 30) submerged one hand into cold water (3.3 ± 0.8°C) for 5 min. Blood pressure, heart rate, cardiac output, and cardiac parameters were recorded using an automated monitor, impedance cardiography, and a beat-to-beat monitoring system. We analyzed for salivary α-amylase (SαA), which is a convenient biomarker of the sympathetic nervous system. Subjects were stratified post hoc into hyper-responders (≥ 22 mmHg) and hypo-responders (< 22 mmHg) based on change in systolic blood pressure during CPT. Hyper-responders had a significantly lower baseline heart rate (64 ± 7 bpm), cardiac output (5.6 ± 0.9 L · min-1), and SαA (60 ± 37 U · mL-1) compared to hypo-responders (73 ± 9 bpm, 6.9 ± 1.3 L · min-1, 165 ± 122 U · mL-1). During the cold immersion, hyper-responders had significantly higher systolic blood pressure (150 ± 14 mmHg), diastolic blood pressure (91 ± 10 mmHg), mean arterial pressure (129 ± 17 mmHg), and systemic vascular resistance (1780 ± 640 dyn · s-1 · cm-5) than hypo-responders (130 ± 14 mmHg, 81 ± 10 mmHg, 110 ± 9 mmHg, 1290 ± 220 dyn · s-1 · cm-5). The change in systolic blood pressure correlated with baseline SαA (r = -0.455, P = 0.011) and baseline heart rate (r = -0.374, P = 0.042). Baseline characteristics influenced by sympathetic tone such as SαA, heart rate, and cardiac output are indicative of responses to CPT. Our data supports the use of baseline values to predict blood pressure response to acute cold exposure and indicates an intrinsic difference between CPT responder phenotypes.Youssef M, Ghassemi A, Carvajal Gonczi CM, Kugathasan TA, Kilgour RD, Darlington PJ. Low baseline sympathetic tone correlates to a greater blood pressure change in the cold pressor test. Aerosp Med Hum Perform. 2018; 89(6):503-509.
Arveschoug, A K; Revsbech, P; Brøchner-Mortensen, J
1998-07-01
Using the determination of distal blood pressure (DBP) measured using the strain gauge technique as an example of a routine clinical physiological investigation involving many different observers (laboratory technicians), the present study was carried out to assess (1) the influence of the number of observers and the number of analyses made by each observer on the precision of a definitive value; and (2) the minimal difference between two determinations to detect a real change. A total of 45 patients participated in the study. They were all referred for DBP determination on suspicion of arterial peripheral vascular disease. In 30 of the patients, the DBP curves were read twice, with a 5-week interval, by 10 laboratory technicians. The results were analysed using the variance component model. The remaining 15 patients had their DBP determined twice on two different days with an interval of 1-3 days and the total day-to-day variation (SDdiff) of DBP was determined. The inter- and intraobserver variations were, respectively, 5.7 and 4.9 mmHg at ankle level and 3.5 and 2.7 mmHg at toe level. The index values as related to systolic pressure were somewhat lower. The mean day-to-day variation was 11 mmHg at ankle level and 10 mmHg at toe level, thereby giving a minimal significant difference between two DBP determinations of 22 mmHg at ankle and 20 mmHg at toe level. To decrease the value of SD (standard deviation) on a definitive determination of DBP and index values, it was slightly more effective if the value was based on two observers performing one independent DBP curve reading than if one observer made one or two DBP curve readings. The reduction in SDdiff was greatest at ankle level. The extent of the Sddiff decrease was greatest when two different observers made a single DBP reading each at both determinations compared with one different observer making two readings at each determination. Surprisingly, about half of the maximum reduction in the SDdiff was achieved just by increasing the number of observers from one to two. We have found variance component analyses to be a suitable method for determining intra- and interobserver variation when several different observers take part in a routine laboratory investigation. It may be applied to other laboratory methods such as renography, isotope cardiography and myocardial perfusion single-photon emission computerized tomography (SPECT) scintigraphy, in which the final result may be affected by individual judgement during processing.
2012-01-01
Background In this paper a new non-invasive, operator-free, continuous ventricular stroke volume monitoring device (Hemodynamic Cardiac Profiler, HCP) is presented, that measures the average stroke volume (SV) for each period of 20 seconds, as well as ventricular volume-time curves for each cardiac cycle, using a new electric method (Ventricular Field Recognition) with six independent electrode pairs distributed over the frontal thoracic skin. In contrast to existing non-invasive electric methods, our method does not use the algorithms of impedance or bioreactance cardiography. Instead, our method is based on specific 2D spatial patterns on the thoracic skin, representing the distribution, over the thorax, of changes in the applied current field caused by cardiac volume changes during the cardiac cycle. Since total heart volume variation during the cardiac cycle is a poor indicator for ventricular stroke volume, our HCP separates atrial filling effects from ventricular filling effects, and retrieves the volume changes of only the ventricles. Methods ex-vivo experiments on a post-mortem human heart have been performed to measure the effects of increasing the blood volume inside the ventricles in isolation, leaving the atrial volume invariant (which can not be done in-vivo). These effects have been measured as a specific 2D pattern of voltage changes on the thoracic skin. Furthermore, a working prototype of the HCP has been developed that uses these ex-vivo results in an algorithm to decompose voltage changes, that were measured in-vivo by the HCP on the thoracic skin of a human volunteer, into an atrial component and a ventricular component, in almost real-time (with a delay of maximally 39 seconds). The HCP prototype has been tested in-vivo on 7 human volunteers, using G-suit inflation and deflation to provoke stroke volume changes, and LVot Doppler as a reference technique. Results The ex-vivo measurements showed that ventricular filling caused a pattern over the thorax quite distinct from that of atrial filling. The in-vivo tests of the HCP with LVot Doppler resulted in a Pearson’s correlation of R = 0.892, and Bland-Altman plotting of SV yielded a mean bias of -1.6 ml and 2SD =14.8 ml. Conclusions The results indicate that the HCP was able to track the changes in ventricular stroke volume reliably. Furthermore, the HCP produced ventricular volume-time curves that were consistent with the literature, and may be a diagnostic tool as well. PMID:22900831
Belyi, D; Pleskach, G; Nastina, O; Sidorenko, G; Kursina, N; Bazyka, O; Kovalev, O; Chumak, A; Abramenko, I
2016-12-01
This study devoted to specific features of coronary heart disease (CHD) development in emergency work ers (EW) of the accident at the Chernobyl nuclear power plant (ChNPP) based on analysis the interaction between radiation and non radiation risk factors and single nucleotide polymorphism (SNP) rs966221 of phosphodiesterase (PDE) 4D gene. It was examined 397 men with CHD, including 274 EW of 1986-1987 and 123 non irradiated persons (con trol group) who were 66±10 and 69±11 years old relatively. The program studies included clinical examination, elec trocardiography (ECG), ECG daily monitoring, ECG stress testing, echo doppler cardiography, analysis of serum lipid spectrum, polymerase chain reaction with restriction of reaction products, retrospective analysis of case histories. Diagnosis of CHD or its approval was carried out in accordance with the standards of diagnosis, accepted in Ukraine. All EW before their taking part in cleaning ChNPP territory did not suffered from CHD. According to the analysis of contingency tables, carriers of the TT genotype of rs966221 increased the risk of myocardial infarction (MI) in 2.538 times compared with carriers of genotypes CC and CT. The use of Kaplan Meier method showed that a half of EW with the TT genotype developed MI before 64 years old, while with the other geno types up to 78.7 years old. In the control group statistically significant increase of cumulative proportion of patients with MI, carriers of the TT genotype, began from 60 years old. Compared to the non irradiated patients EW fell ill with CHD on 9.4 years earlier. Using proportional hazards analysis (Cox regression), it was found that EW had 3.9 times higher risk of CHD than in non irradiated individuals. Smoking and overweight brought three times less but significant risk - 1.37 and 1.33 respectively. The TT genotype unlike genotypes CC and CT gene PDE4D increased risk of MI in 1.757 times more both in EW and control group. The risk of CHD development was determined by radiation factor, such as the involvement in the emer gency works of the accident consequences, as well as non radiation factors, namely smoking and overweight. Only one factor, the TT genotype of rs966221 PDE4D gene, determined the risk of MI occurrence in EW and non irradiated controls. In the post emergency period, CHD developed 6 years earlier in EW with the TT genotype than in patients with genotypes CC and CT. D. Belyi, G. Pleskach, O. Nastina, G. Sidorenko, N. Kursina, O. Bazyka, O. Kovalev, A. Chumak, I. Abramenko.
L-arginine-induced vasodilation in healthy humans: pharmacokinetic–pharmacodynamic relationship
Bode-Böger, Stefanie M; Böger, Rainer H; Galland, Andrea; Tsikas, Dimitrios; Frölich, Jürgen C
1998-01-01
Aims Administration of l-arginine by intravenous infusion or via oral absorption has been shown to induce peripheral vasodilation in humans, and to improve endothelium-dependent vasodilation. We investigated the pharmacokinetics and pharmacokinetic-pharmacodynamic relationship of l-arginine after a single intravenous infusion of 30 g or 6 g, or after a single oral application of 6 g, as compared with the respective placebo, in eight healthy male human subjects. Methods l-arginine levels were determined by h.p.l.c. The vasodilator effects of l-arginine were assessed non-invasively by blood pressure monitoring and impedance cardiography. Urinary nitrate and cyclic GMP excretion rates were measured as non-invasive indicators of endogenous NO production. Results Plasma l-arginine levels increased to (mean±s.e.mean) 6223±407 (range, 5100–7680) and 822±59 (527–955) μmol l−1 after intravenous infusion of 30 g and 6 g l-arginine, respectively, and to 310±152 (118–1219) μmol l−1 after oral ingestion of 6 g l-arginine. Oral bioavailability of l-arginine was 68±9 (51–87)%. Clearance was 544±24 (440–620), 894±164 (470–1190), and 1018±230 (710–2130) ml min−1, and elimination half-life was calculated as 41.6±2.3 (34–55), 59.6±9.1 (24–98), and 79.5±9.3 (50–121) min, respectively, for 30 g i.v., 6 g i.v., and 6 g p.o. of l-arginine. Blood pressure and total peripheral resistance were significantly decreased after intravenous infusion of 30 g l-arginine by 4.4±1.4% and 10.4±3.6%, respectively, but were not significantly changed after oral or intravenous administration of 6 g l-arginine. l-arginine (30 g) also significantly increased urinary nitrate and cyclic GMP excretion rates by 97±28 and 66±20%, respectively. After infusion of 6 g l-arginine, urinary nitrate excretion also significantly increased, (nitrate by 47±12% [P < 0.05], cyclic GMP by 67±47% [P = ns]), although to a lesser and more variable extent than after 30 g of l-arginine. The onset and the duration of the vasodilator effect of l-arginine and its effects on endogenous NO production closely corresponded to the plasma concentration half-life of l-arginine, as indicated by an equilibration half-life of 6±2 (3.7–8.4) min between plasma concentration and effect in pharmacokinetic-pharmacodynamic analysis, and the lack of hysteresis in the plasma concentration-versus-effect plot. Conclusions The vascular effects of l-arginine are closely correlated with its plasma concentrations. These data may provide a basis for the utilization of l-arginine in cardiovascular diseases. PMID:9833603
Taha, Nima; Zhang, Jing; Ranjan, Rupesh; Daneshvar, Samuel; Castillo, Edilzar; Guillen, Elizabeth; Montoya, Martha C; Velasquez, Giovanna; Naqvi, Tasneem Z
2010-08-01
Doppler echocardiography of mitral inflow or aortic outflow or both has been validated and advocated to guide biventricular (Biv) pacemaker optimization. A comprehensive and tailored Doppler echocardiographic evaluation may be required in patients with heart failure to assist with Biv pacemaker optimization. The third heart sound (S(3)), an acoustic cardiographic parameter, has been demonstrated to be a highly specific finding for hemodynamic evaluation in patients with heart failure. The aims of this study were to evaluate the use of comprehensive Doppler echocardiography as a guide during Biv pacemaker optimization in patients after cardiac resynchronization therapy and to evaluate the feasibility of S(3) intensity to be a cost-efficient parameter for Biv pacemaker optimization compared with Doppler echocardiography. Comprehensive Doppler echocardiographic evaluations were performed during Biv pacemaker optimization in 44 patients referred for pacemaker optimization (mean age, 71 + or - 12 years; mean left ventricular ejection fraction, 34 + or - 11%). Blinded assessment of S(3) intensity was performed simultaneously using acoustic cardiography. The correlation and improvement in cardiac hemodynamics were analyzed between the methods. Echocardiographically guided optimization resulted in significant improvements in the left ventricular outflow velocity-time integral (15.92 + or - 4.77 to 18.51 + or - 5.19 cm, P < .001), ejection time (278 + or - 40 to 293 + or - 40 ms, P < .001), myocardial performance index (0.57 + or - 0.19 to 0.44 + or - 0.14, P < .002), and peak pulmonary artery systolic pressure (42 + or - 13 to 36 + or - 11 mm Hg, P < .04) and decreased S(3) intensity from 4.81 + or - 1.84 at baseline to 3.96 + or - 1.22 after optimization (P < .02) for the overall study group and from 6.63 + or - 1.37 to 4.85 + or - 1.13 (P < .001) in the 18 patients with baseline S(3) intensity > 5.0. The correlation between echocardiographic and acoustic cardiographic S(3) intensity for optimal atrioventricular delay was 0.86 (P < .001) and for optimal interventricular delay was 0.64 (P < .001). Optimal atrioventricular delay was identical by echocardiographic and acoustic cardiographic S(3) intensity in 56%, and optimal interventricular delay was identical in 75% of patients. Pacemakers were permanently programmed on the basis of echocardiographic evaluation. In 35 patients available for follow up, the mean New York Heart Association class reduced from 2.55 + or - 0.81 to 1.77 + or - 0.90 (P < .001) and the mean quality-of-life score as assessed by Minnesota Living With Heart Failure Questionnaire improved from 45 + or - 28 to 32 + or - 28 (P = .08) at 2.5 + or - 2.1 months. Comprehensive echocardiographically guided Biv pacemaker optimization produces significant improvement in Doppler echocardiographic hemodynamics, a reduction in S(3) intensity, and an improvement in functional class in patients after cardiac resynchronization therapy. Copyright 2010 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Baranov, V. M.; Baevsky, R. M.; Drescher, J.; Tank, J.
parameters describing the results of the function of these systems like heart rate, arterial pressure, cardiac output, or breathing frequency, concentration of O2 and CO2 , etc. Missing significant changes of these parameters during weightlessness supports the hypothesis that adaptational and compensatory mechanisms are sufficient and guarantee cardiovascular homeostasis under changing environmental conditions. characteristic changes of the vegetative balance and of the activity of different regulatory elements at the brainstem and subcortical level. This changes guaranteed the adaptation to long term weightlessness. However, it remains unclear to what extent the different levels are involved. Moreover, the criteria describing the efficacy of cardiorespiratory interaction for the different functional states are not defined yet. The investigation of this problems is highly relevant in order to improve the medical control, especially if considering that the disruption of regulatory systems mostly precedes dangerous destruction of homeostasis. cardiovascular and respiratory function on Board the International Space Station (ISS) aiming to obtain new insights into the interaction between different regulatory elements. "Puls" is measures ECG, photoplethysmogram (PPG), and the pneumotachogram (PTG). The ECG is used to measure time series of R-R intervals and to analyse HRV. PPG is used to define the pulse wave velocity, phases of the cardiac cycle, and an estimate of the filling of finger vessels. The variability of these parameters is also calculated and compared to HRV. The analysis of the PTG allows to describe the interaction of the regulatory parameters of the cardiovascular and respiratory systems. Hence, an important feature of the experiment "Puls" is the investigation of regulatory mechanisms rather than of cardiovascular homeostasis. cardiography) and left ventricular contractility (seismocardiography) will be obtained. This expansion is of major importance because, it allows us to get deeper insight into regulatory mechanisms of the cardiorespiratory system and into the state of cardiovascular homeostasis. have the same size (90 x 60 x 20 mm), identical technology, and identical interfaces with the computer. the onboard experiment and to store the obtained data; 2) "Editor": to archive and dearchive the obtained data, to edit them and to insert necessary comments and markers; 3) "Earth": to edit and analyse the data under laboratory conditions.The subprogram "Earth" is an original software package for data analysis, peak detection, calculation of a variety of parameters, time series forming and editing, statistical and spectral time series analysis. Furthermore, a specialized data base is designated for storing of the biosignals, results of analysis, information about the investigated subjects and comments of simple autonomic function tests will allow to assess different elements of the regulatory mechanisms. Special interest will be given to respiratory tests in order to evaluate the interaction between the cardiovascular system and respiration. volunteers and in patients with different cardiovascular diseases. The results were used to establish normal values and criteria for the prognosis of pathologic changes. These materials will be used at valuation the data obtained during researches on ISS. respiratory systems onboard the ISS are the following: 1) definition of the most important parameters, which can be measured simple and reliable during weightlessness; 2) development of miniaturized devices which can be kept on the astronauts body and which could be used in future as an autonomic system of operational medical control; 3) development of original software packages which allow to detect prognostic changes of the regulatory pattern preceding diseases and based on time series analysis of a large number of cardiorespiratory parameters.
Maternal hemodynamics: a method to classify hypertensive disorders of pregnancy.
Ferrazzi, Enrico; Stampalija, Tamara; Monasta, Lorenzo; Di Martino, Daniela; Vonck, Sharona; Gyselaers, Wilfried
2018-01-01
The classification of hypertensive disorders of pregnancy is based on the time at the onset of hypertension, proteinuria, and other associated complications. Maternal hemodynamic interrogation in hypertensive disorders of pregnancy considers not only the peripheral blood pressure but also the entire cardiovascular system, and it might help to classify the different clinical phenotypes of this syndrome. This study aimed to examine cardiovascular parameters in a cohort of patients affected by hypertensive disorders of pregnancy according to the clinical phenotypes that prioritize fetoplacental characteristics and not the time at onset of hypertensive disorders of pregnancy. At the fetal-maternal medicine unit of Ziekenhuis Oost-Limburg (Genk, Belgium), maternal cardiovascular parameters were obtained through impedance cardiography using a noninvasive continuous cardiac output monitor with the patients placed in a standing position. The patients were classified as pregnant women with hypertensive disorders of pregnancy who delivered appropriate- and small-for-gestational-age fetuses. Normotensive pregnant women with an appropriate-for-gestational-age fetus at delivery were enrolled as the control group. The possible impact of obesity (body mass index ≥30 kg/m 2 ) on maternal hemodynamics was reassessed in the same groups. Maternal age, parity, body mass index, and blood pressure were not significantly different between the hypertensive disorders of pregnancy/appropriate-for-gestational-age and hypertensive disorders of pregnancy/small-for-gestational-age groups. The mean uterine artery pulsatility index was significantly higher in the hypertensive disorders of pregnancy/small-for-gestational-age group. The cardiac output and cardiac index were significantly lower in the hypertensive disorders of pregnancy/small-for-gestational-age group (cardiac output 6.5 L/min, cardiac index 3.6) than in the hypertensive disorders of pregnancy/appropriate-for-gestational-age group (cardiac output 7.6 L/min, cardiac index 3.9) but not between the hypertensive disorders of pregnancy/appropriate-for-gestational-age and control groups (cardiac output 7.6 L/min, cardiac index 4.0). Total vascular resistance was significantly higher in the hypertensive disorders of pregnancy/small-for-gestational-age group than in the hypertensive disorders of pregnancy/appropriate-for-gestational-age group and the control group. All women with hypertensive disorders of pregnancy showed signs of central arterial dysfunction. The cardiovascular parameters were not influenced by gestational age at the onset of hypertensive disorders of pregnancy, and no difference was observed between the women with appropriate-for-gestational-age fetuses affected by preeclampsia or by gestational hypertension with appropriate-for-gestational-age fetuses. Women in the obese/hypertensive disorders of pregnancy/appropriate-for-gestational-age and obese/hypertensive disorders of pregnancy/small-for-gestational-age groups showed a significant increase in cardiac output, as well as significant changes in other parameters, compared with the nonobese/hypertensive disorders of pregnancy/appropriate-for-gestational-age and nonobese/hypertensive disorders of pregnancy/small-for-gestational-age groups. Significantly low cardiac output and high total vascular resistance characterized the women with hypertensive disorders of pregnancy associated with small for gestational age due to placental insufficiency, independent of the gestational age at the onset of hypertension. The cardiovascular parameters were not significantly different in the women with appropriate-for-gestational-age or small-for-gestational-age fetuses affected by preeclampsia or gestational hypertension. These findings support the view that maternal hemodynamics may be a candidate diagnostic tool to identify hypertensive disorders in pregnancies associated with small-for-gestational-age fetuses. This additional tool matches other reported evidence provided by uterine Doppler velocimetry, low vascular growth factors in the first trimester, and placental pathology. Obesity is associated with a significantly higher cardiac output and outweighs other determinants of hemodynamics in pregnancy; therefore, in future studies on hypertensive disorders, obesity should be studied as an additional disease and not simply as a demographic characteristic. Copyright © 2017 Elsevier Inc. All rights reserved.