Sample records for care simple tips

  1. Two-photon excited fluorescence from a pseudoisocyanine-attached gold-coated tip via a thin tapered fiber under a weak continuous wave excitation.

    PubMed

    Ren, Fang; Takashima, Hideaki; Tanaka, Yoshito; Fujiwara, Hideki; Sasaki, Keiji

    2013-11-18

    A simple tapered fiber based photonic-plasmonic hybrid nanostructure composed of a thin tapered fiber and a pseudoisocyanine (PIC)-attached Au-coated tip was demonstrated. Using this simple hybrid nanostructure, we succeeded in observing two-photon excited fluorescence from the PIC dye molecules under a weak continuous wave excitation condition. From the results of the tip-fiber distance dependence and excitation polarization dependence, we found that using a thin tapered fiber and an Au-coated tip realized efficient coupling of the incident light (~95%) and LSP excitation at the Au-coated tip, suggesting the possibility of efficiently inducing two-photon excited fluorescence from the PIC dye molecules attached on the Au-coated tip. This simple photonic-plasmonic hybrid system is one of the promising tools for single photon sources, highly efficient plasmonic sensors, and integrated nonlinear plasmonic devices.

  2. 77 FR 56912 - Proposed Collection; Comment Request for Form 2438

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-14

    ... Program for SIMPLE IRAs; Revenue Procedure 2006-30, Restaurant Tips--Attributed Tip Income Program (ATIP... Reporting Burden Hours: 25,870. (3) Title: Restaurant Tips--Attributed Tip Income Program (ATIP). OMB Number...

  3. Rapid determination of triclosan in personal care products using new in-tube based ultrasound-assisted salt-induced liquid-liquid microextraction coupled with high performance liquid chromatography-ultraviolet detection.

    PubMed

    Chen, Ming-Jen; Liu, Ya-Ting; Lin, Chiao-Wen; Ponnusamy, Vinoth Kumar; Jen, Jen-Fon

    2013-03-12

    This paper describes the development of a novel, simple and efficient in-tube based ultrasound-assisted salt-induced liquid-liquid microextraction (IT-USA-SI-LLME) technique for the rapid determination of triclosan (TCS) in personal care products by high performance liquid chromatography-ultraviolet (HPLC-UV) detection. IT-USA-SI-LLME method is based on the rapid phase separation of water-miscible organic solvent from the aqueous phase in the presence of high concentration of salt (salting-out phenomena) under ultrasonication. In the present work, an indigenously fabricated home-made glass extraction device (8-mL glass tube inbuilt with a self-scaled capillary tip) was utilized as the phase separation device for USA-SI-LLME. After the extraction, the upper extractant layer was narrowed into the self-scaled capillary tip by pushing the plunger plug; thus, the collection and measurement of the upper organic solvent layer was simple and convenient. The effects of various parameters on the extraction efficiency were thoroughly evaluated and optimized. Under optimal conditions, detection was linear in the concentration range of 0.4-100ngmL(-1) with correlation coefficient of 0.9968. The limit of detection was 0.09ngmL(-1) and the relative standard deviations ranged between 0.8 and 5.3% (n=5). The applicability of the developed method was demonstrated for the analysis of TCS in different commercial personal care products and the relative recoveries ranged from 90.4 to 98.5%. The present method was proven to be a simple, sensitive, less organic solvent consuming, inexpensive and rapid procedure for analysis of TCS in a variety of commercially available personal care products or cosmetic preparations. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Calculation of tip clearance effects in a transonic compressor rotor

    NASA Technical Reports Server (NTRS)

    Chima, R. V.

    1996-01-01

    The flow through the tip clearance region of a transonic compressor rotor (NASA rotor 37) was computed and compared to aerodynamic probe and laser anemometer data. Tip clearance effects were modeled both by gridding the clearance gap and by using a simple periodicity model across the ungridded gap. The simple model was run with both the full gap height, and with half the gap height to simulate a vena-contracta effect. Comparisons between computed and measured performance maps and downstream profiles were used to validate the models and to assess the effects of gap height on the simple clearance model. Recommendations were made concerning the use of the simple clearance model. Detailed comparisons were made between the gridded clearance gap solution and the laser anemometer data near the tip at two operating points. The computer results agreed fairly well with the data but overpredicted the extent of the casing separation and underpredicted the wake decay rate. The computations were then used to describe the interaction of the tip vortex, the passage shock, and the casing boundary layer.

  5. Time To Talk with Your Health Care Providers: 4 Tips to Start the Conversation

    MedlinePlus

    ... Y Z 4 Tips: Start Talking With Your Health Care Providers About Complementary Health Approaches Share: When patients ... fully informed and can help patients make wise health care decisions. Here are 4 tips to help you ...

  6. Nanotechnology in Space Exploration: Report of the National Nanotechnology Initiative Workshop Held in Palo Alto, California on 24-26 August 2004

    DTIC Science & Technology

    2006-01-01

    Nanosensors and Instrumentation Nanotechnology in Space Exploration 19 simple, rugged design. Multiwalled carbon nanotube ( MWCNT ) cathodes were grown...probe tips. Existing approaches use both SWCNTs and MWCNTs . A unique fabrication process development at NASA Ames (see ref. [4] in Chapter 6...produces very robust MWCNT tips with a high aspect ratio (> 1 µm in length and 10 nm to 20 nm in diameter). In addition, a novel and simple tip sharpening

  7. Evaluation of the overweight/obese child--practical tips for the primary health care provider: recommendations from the Childhood Obesity Task Force of the European Association for the Study of Obesity.

    PubMed

    Baker, Jennifer L; Farpour-Lambert, Nathalie J; Nowicka, Paulina; Pietrobelli, Angelo; Weiss, Ram

    2010-01-01

    The prevalence of obesity among children and adolescents is on the rise. The majority of overweight or obese children are treated by primary health care providers including paediatricians, family practitioners, dieticians, nurses, and school health services - and not by specialists. The majority of obese children have no underlying medical disorder causing their obesity yet a significant proportion might suffer from obesity-related co-morbidities. This text is aimed at providing simple and practical tools for the identification and management of children with or at risk of overweight and obesity in the primary care setting. The tips and tools provided are based on data from the recent body of work that has been published in this field, official statements of several scientific societies along with expert opinion provided by the members of the Childhood Obesity Task Force (COTF) of the European Association for the Study of Obesity (EASO). We have attempted to use an evidence-based approach while allowing flexibility for the practicing clinician in domains where evidence is currently lacking and ensuring that treating the obese child involves the entire family as well. Copyright 2010 S. Karger AG, Basel.

  8. Cellular and dendritic growth in a binary melt - A marginal stability approach

    NASA Technical Reports Server (NTRS)

    Laxmanan, V.

    1986-01-01

    A simple model for the constrained growth of an array of cells or dendrites in a binary alloy in the presence of an imposed positive temperature gradient in the liquid is proposed, with the dendritic or cell tip radius calculated using the marginal stability criterion of Langer and Muller-Krumbhaar (1977). This approach, an approach adopting the ad hoc assumption of minimum undercooling at the cell or dendrite tip, and an approach based on the stability criterion of Trivedi (1980) all predict tip radii to within 30 percent of each other, and yield a simple relationship between the tip radius and the growth conditions. Good agreement is found between predictions and data obtained in a succinonitrile-acetone system, and under the present experimental conditions, the dendritic tip stability parameter value is found to be twice that obtained previously, possibly due to a transition in morphology from a cellular structure with just a few side branches, to a more fully developed dendritic structure.

  9. Practical Parenting Tips: Over 1,500 Helpful Hints for the First Five Years. Revised and Updated.

    ERIC Educational Resources Information Center

    Lansky, Vicki

    Noting that other parents can be an excellent source of practical parenting advice, this book compiles over a thousand practical tips--those not generally found in baby care books or pediatrician's offices--with over 400 new tips compiled since the book's 1982 version. Major topics include: (1) new baby care, including cesarean deliveries,…

  10. The results of a wind tunnel investigation of a model rotor with a free tip

    NASA Technical Reports Server (NTRS)

    Stroub, Robert H.; Young, Larry A.

    1985-01-01

    The results of a wind-tunnel test of the free tip rotor are presented. The free tip extended over the outer 10% of the rotor blade and included a simple, passive controller mechanism. Wind-tunnel test hardware is described. The free-tip assembly, which includes the controller, functioned flawlessly throughout the test. The tip pitched freely and responded to airflow perturbation in a sharp, quick, and stable manner. Tip pitch-angle responses are presented for an advance ratio range of 0.1 to 0.397 and for a thrust coefficient range of 0.038 to 0.092. The free tip reduced power requirements, loads going into the control system, and some flatwise blade-bending moments. Chordwise loads were not reduced by the free tip.

  11. Sleep Tips: 7 Steps to Better Sleep

    MedlinePlus

    ... turn every night. Consider simple tips for better sleep, from setting a sleep schedule to including physical activity in your daily ... factors that can interfere with a good night's sleep — from work stress and family responsibilities to unexpected ...

  12. Top 10 Tips for Taking an Elderly Parent to the Emergency Department

    MedlinePlus

    ... Department Top 10 Tips for Taking an Elderly Parent to the Emergency Department With America's rapidly growing ... to seek emergency care. Caring for an elderly parent is one of the most important things an ...

  13. Compound parabolic concentrator optical fiber tip for FRET-based fluorescent sensors

    NASA Astrophysics Data System (ADS)

    Ul Hassan, Hafeez; Nielsen, Kristian; Aasmul, Soren; Bang, Ole

    2015-09-01

    The Compound Parabolic Concentrator (CPC) optical fiber tip shape has been proposed for intensity based fluorescent sensors working on the principle of FRET (Förster Resonance Energy Transfer). A simple numerical Zemax model has been used to optimize the CPC tip geometry for a step-index multimode polymer optical fiber for an excitation and emission wavelength of 550 nm and 650nm, respectively. The model suggests an increase of a factor of 1.6 to 4 in the collected fluorescent power for an ideal CPC tip, as compared to the plane-cut fiber tip for fiber lengths between 5 and 45mm.

  14. Talking about Complementary and Alternative Medicine with Health Care Providers: A Workbook and Tips

    Cancer.gov

    A workbook to help patients and doctors talk about the use of complementary and alternative medicine(CAM) during and after cancer care. Worksheets, tips, and resources are provided for patients and doctors to help track CAM use.

  15. Talking about Complementary and Alternative Medicine with Health Care Provider: A Workbook and Tips

    Cancer.gov

    A workbook to help patients and doctors talk about the use of complementary and alternative medicine(CAM) during and after cancer care. Worksheets, tips, and resources are provided for patients and doctors to help track CAM use.

  16. Contrast enhanced computed tomography and reconstruction of hepatic vascular system for transjugular intrahepatic portal systemic shunt puncture path planning.

    PubMed

    Qin, Jian-Ping; Tang, Shan-Hong; Jiang, Ming-De; He, Qian-Wen; Chen, Hong-Bin; Yao, Xin; Zeng, Wei-Zheng; Gu, Ming

    2015-08-28

    To describe a method for the transjugular intrahepatic portal systemic shunt (TIPS) placement performed with the aid of contrast-enhanced computed tomography (CECT) and three-dimensional reconstructed vascular images (3D RVIs), and to assess its safety and effectiveness. Four hundred and ninety patients were treated with TIPS between January 2005 and December 2012. All patients underwent liver CECT and reconstruction of 3D RVIs of the right hepatic vein to portal vein (PV) prior to the operation. The 3D RVIs were carefully reviewed to plan the puncture path from the start to target points for needle pass through the PV in the TIPS procedure. The improved TIPS procedure was successful in 483 (98.6%) of the 490 patients. The number of punctures attempted was one in 294 (60%) patients, 2 to 3 in 147 (30%) patients, 4 to 6 in 25 (5.1%) patients and more than 6 in 17 (3.5%) patients. Seven patients failed. Of the 490 patients, 12 had punctures into the artery, 15 into the bile duct, eight into the gallbladder, and 18 through the liver capsule. Analysis of the portograms from the 483 successful cases indicated that the puncture points were all located distally to the PV bifurcation on anteroposterior images, while the points were located proximally to the bifurcation in the three cases with intraabdominal bleeding. The complications included three cases of bleeding, of whom one died and two needed surgery. Use of CECT and 3D RVIs to plan the puncture path for TIPS procedure is safe, simple and effective for clinical use.

  17. Reference system for scanning probe tip fingerprinting

    NASA Astrophysics Data System (ADS)

    Turansky, Robert; Bamidele, Joseph; Sugawara, Yasuhiro; Kantorovitch, Lev; Stich, Ivan

    2012-02-01

    Knowledge of the chemical structure of the tip asperity in Non-Contact Atomic Force Microscopy (NC-AFM) is crucial as controlled manipulation of atoms and/or molecules on surfaces can only be performed if this information is available. However, a simple and robust protocol for ensuring a specific tip termination has not yet been developed. We propose a procedure for chemical tip finger printing and an example of a reference system, the oxygen-terminated Cu(110) surface, that enables one to ensure a specific tip termination with Si, Cu, or O atoms. To follow this up and unambiguously determine tip types, we performed a theoretical DFT study of the line scans with the tip models in question and found that the tip characterization made based on experimental results (Cu/O-terminated tip imaging Cu/O atoms) is in fact incorrect and the opposite is true (Cu/O-terminated tip imaging O/Cu atoms). This protocol allows the tip asperity's chemical structure to be verified and established both before as well as at any stage of the manipulation experiment when numerous tip changes may take place.

  18. Talking about Complementary and Alternative Medicine with your Health Care Provider: A workbook and tips

    Cancer.gov

    A workbook to help patients and doctors talk about the use of complementary and alternative medicine(CAM) during and after cancer care. Worksheets, tips, and resources are provided for patients and doctors to help track CAM use.

  19. Talking about complementary and alternative medicine with your health care provider: A workbook and Tips

    Cancer.gov

    A workbook to help patients and doctors talk about the use of complementary and alternative medicine(CAM) during and after cancer care. Worksheets, tips, and resources are provided for patients and doctors to help track CAM use.

  20. Make Celebrations Fun, Healthy, and Active: 10 Tips to Creating Healthy, Active Events

    MedlinePlus

    United States Department of Agriculture 10 tips Nutrition Education Series MyPlate MyWins Based on the Dietary Guidelines for Americans Make celebrations ... out some of the recipes on WhatsCooking.fns.usda.gov. 8 Keep it simple Have others participate ...

  1. A simple method to prevent hard X-ray-induced preheating effects inside the cone tip in indirect-drive fast ignition implosions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Dongxiao; Shan, Lianqiang; Zhou, Weimin

    During fast-ignition implosions, preheating of inside the cone tip caused by hard X-rays can strongly affect the generation and transport of hot electrons in the cone. Although indirect-drive implosions have a higher implosion symmetry, they cause stronger preheating effects than direct-drive implosions. To control the preheating of the cone tip, we propose the use of indirect-drive fast-ignition targets with thicker tips. Experiments carried out at the ShenGuang-III prototype laser facility confirmed that thicker tips are effective for controlling preheating. Moreover, these results were consistent with those of 1D radiation hydrodynamic simulations.

  2. Keep It Simple. Teaching Tips for Special Olympic Athletes.

    ERIC Educational Resources Information Center

    Johnston, Judith E.; And Others

    1996-01-01

    Physical educators can help Special Olympics athletes learn cross-lateral delivery techniques for bowling or throwing softballs by color coding the throwing arm and opposing foot. The article explains color coding, presenting teaching tips for both sports. A series of workshops on modifying exercise principles for individuals with physical…

  3. Thirty Simple Ideas for Interactive Whiteboards

    ERIC Educational Resources Information Center

    Adams, Caralee

    2011-01-01

    This article presents thirty simple ideas for interactive whiteboards and how IWB can make one's teaching life easier. These teaching ideas for the interactive whiteboard can be used by teachers every day. Tips for classroom management are also presented.

  4. Application of da Vinci(®) Robot in simple or radical hysterectomy: Tips and tricks.

    PubMed

    Iavazzo, Christos; Gkegkes, Ioannis D

    2016-01-01

    The first robotic simple hysterectomy was performed more than 10 years ago. These days, robotic-assisted hysterectomy is accepted as an alternative surgical approach and is applied both in benign and malignant surgical entities. The two important points that should be taken into account to optimize postoperative outcomes in the early period of a surgeon's training are how to achieve optimal oncological and functional results. Overcoming any technical challenge, as with any innovative surgical method, leads to an improved surgical operation timewise as well as for patients' safety. The standardization of the technique and recognition of critical anatomical landmarks are essential for optimal oncological and clinical outcomes on both simple and radical robotic-assisted hysterectomy. Based on our experience, our intention is to present user-friendly tips and tricks to optimize the application of a da Vinci® robot in simple or radical hysterectomies.

  5. Evaluation of the eZono 4000 with eZGuide for ultrasound-guided procedures.

    PubMed

    Gadsden, Jeff; Latmore, Malikah; Levine, Daniel M

    2015-05-01

    Ultrasound-guided procedures are increasingly common in a variety of acute care settings, such as the operating room, critical care unit and emergency room. However, accurate judgment of needle tip position using traditional ultrasound technology is frequently difficult, and serious injury can result from inadvertently advancing beyond or through the target. Needle navigation is a recent innovation that allows the clinician to visualize the needle position and trajectory in real time as it approaches the target. A novel ultrasound machine has recently been introduced that is portable and designed for procedural guidance. The eZono 4000™ features an innovative needle navigation technology that is simple to use and permits the use of a wide range of commercially available needles, avoiding the inconvenience and cost of proprietary equipment. This article discusses this new ultrasound machine in the context of other currently available ultrasound machines featuring needle navigation.

  6. DIY Tomography sample holder

    NASA Astrophysics Data System (ADS)

    Lari, L.; Wright, I.; Boyes, E. D.

    2015-10-01

    A very simple tomography sample holder at minimal cost was developed in-house. The holder is based on a JEOL single tilt fast exchange sample holder where its exchangeable tip was modified to allow high angle degree tilt. The shape of the tip was designed to retain mechanical stability while minimising the lateral size of the tip. The sample can be mounted on as for a standard 3mm Cu grids as well as semi-circular grids from FIB sample preparation. Applications of the holder on different sample systems are shown.

  7. Key findings on legal and regulatory barriers to HIV testing and access to care across Europe.

    PubMed

    Power, L; Hows, J; Jakobsen, S F

    2018-02-01

    The aim of this work within OptTEST by HiE has been to demonstrate the role of legal and regulatory barriers in hindering access to HIV testing, treatment and care across Europe and to produce tools to help dismantle them. An online survey to assess country-specific data on legal and regulatory barriers distributed widely across the WHO Europe region. Literature reviews conducted in January-October 2015 in English, in November 2015 in Russian, and updated in April 2017. Semi-structured interviews were conducted with 25 key actors within the HIV field to feed into case studies and tip sheets on how to dismantle legal and regulatory barriers. More than 160 individuals and organisations from 49 countries across the WHO European region provided responses which were analysed and cross checked with other data sources and a searchable database produced (legalbarriers.peoplewithhiveurope.org). The conducted literature reviews yielded 88 papers and reports which identify legal and regulatory barriers to key populations' access to HV testing and care. Based on the interviews with key actors, ranging from PLHIV activists to government officials, on lessons-learned, a series of tip sheets and ten case studies were written-up intended to inform and inspire the HIV community to address and overcome existing barriers (opttest.eu/Tools). While some of the barriers identified may require major changes to wider health systems, or long term legal reform, many are open to a simple change in regulations or custom and practice. We have the tools. Why can't we finish the job? © 2018 British HIV Association.

  8. Sensitive Detection of Small Particles in Fluids Using Optical Fiber Tip with Dielectrophoresis

    PubMed Central

    Tai, Yi-Hsin; Chang, Dao-Ming; Pan, Ming-Yang; Huang, Ding-Wei; Wei, Pei-Kuen

    2016-01-01

    This work presents using a tapered fiber tip coated with thin metallic film to detect small particles in water with high sensitivity. When an AC voltage applied to the Ti/Al coated fiber tip and indium tin oxide (ITO) substrate, a gradient electric field at the fiber tip induced attractive/repulsive force to suspended small particles due to the frequency-dependent dielectrophoresis (DEP) effect. Such DEP force greatly enhanced the concentration of the small particles near the tip. The increase of the local concentration also increased the scattering of surface plasmon wave near the fiber tip. Combined both DEP effect and scattering optical near-field, we show the detection limit of the concentration for 1.36 μm polystyrene beads can be down to 1 particle/mL. The detection limit of the Escherichia coli (E. coli) bacteria was 20 CFU/mL. The fiber tip sensor takes advantages of ultrasmall volume, label-free and simple detection system. PMID:26927128

  9. A novel method for accurate needle-tip identification in trans-rectal ultrasound-based high-dose-rate prostate brachytherapy.

    PubMed

    Zheng, Dandan; Todor, Dorin A

    2011-01-01

    In real-time trans-rectal ultrasound (TRUS)-based high-dose-rate prostate brachytherapy, the accurate identification of needle-tip position is critical for treatment planning and delivery. Currently, needle-tip identification on ultrasound images can be subject to large uncertainty and errors because of ultrasound image quality and imaging artifacts. To address this problem, we developed a method based on physical measurements with simple and practical implementation to improve the accuracy and robustness of needle-tip identification. Our method uses measurements of the residual needle length and an off-line pre-established coordinate transformation factor, to calculate the needle-tip position on the TRUS images. The transformation factor was established through a one-time systematic set of measurements of the probe and template holder positions, applicable to all patients. To compare the accuracy and robustness of the proposed method and the conventional method (ultrasound detection), based on the gold-standard X-ray fluoroscopy, extensive measurements were conducted in water and gel phantoms. In water phantom, our method showed an average tip-detection accuracy of 0.7 mm compared with 1.6 mm of the conventional method. In gel phantom (more realistic and tissue-like), our method maintained its level of accuracy while the uncertainty of the conventional method was 3.4mm on average with maximum values of over 10mm because of imaging artifacts. A novel method based on simple physical measurements was developed to accurately detect the needle-tip position for TRUS-based high-dose-rate prostate brachytherapy. The method demonstrated much improved accuracy and robustness over the conventional method. Copyright © 2011 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  10. Flu Prevention and Treatment Tips

    MedlinePlus

    Flu Prevention and Treatment Tips Expert Information from Healthcare Professionals Who Specialize in the Care of Older Adults Influenza, or the “flu,” is a contagious respiratory illness. It can cause ...

  11. Establishing a profitable skin care practice in a facial plastic surgery office.

    PubMed

    Cortez, Edwin A

    2010-11-01

    Facial plastic surgeons seeking information about establishing and maintaining a first-rate skin care program and practice in their office will learn practice management tips and business advice. This content begins with presenting steps in patient evaluation and continues through development of a care plan. Discussion includes approach to skin care products, sunscreen, and related preventive and restorative methods. Detailed discussion is included of developing a personalized skin care plan. The content concludes with essential business tips and marketing advice for the facial plastic surgeon to include skin care in the surgical practice, including the way in which these are handled in the author's practice. Copyright © 2010 Elsevier Inc. All rights reserved.

  12. A simple, cheap, one-minute method to mount insect pins for use as sharp-tipped probes in plant dissection.

    PubMed

    Frohlich, Michael W

    2005-08-01

    A new method is presented for twist mounting insect pins onto standard dissecting (teasing) needles. Insect pins, with their sharp points, are ideal for fine dissection of plants, especially of shoot tips and early developing flower buds. Twist mounting makes them convenient and effective dissecting tools to prepare specimens for SEM.

  13. One-by-one single-molecule detection of mutated nucleobases by monitoring tunneling current using a DNA tip.

    PubMed

    Bui, Phuc Tan; Nishino, Tomoaki; Shiigi, Hiroshi; Nagaoka, Tsutomu

    2015-01-31

    A DNA molecule was utilized as a probe tip to achieve single-molecule genetic diagnoses. Hybridization of the probe and target DNAs resulted in electron tunneling along the emergent double-stranded DNA. Simple stationary monitoring of the tunneling current leads to single-molecule DNA detection and discovery of base mismatches and methylation.

  14. Measuring water and sediment discharge from a road plot with a settling basin and tipping bucket

    Treesearch

    Thomas A. Black; Charles H. Luce

    2013-01-01

    A simple empirical method quantifies water and sediment production from a forest road surface, and is well suited for calibration and validation of road sediment models. To apply this quantitative method, the hydrologic technician installs bordered plots on existing typical road segments and measures coarse sediment production in a settling tank. When a tipping bucket...

  15. Fitness: Tips for Staying Motivated

    MedlinePlus

    ... life. Review these tips whenever you feel your motivation slipping. Identifying your fitness goals. American Heart Association. ... prescription. Primary Care. 2013;40:801. Physical activity: Motivation. Centers for Disease Control and Prevention. http://www. ...

  16. Psychiatric Mental Health Leadership at the Tipping Point.

    PubMed

    R Delaney, Kathleen

    2015-05-01

    Currently the United States health care system is responding to the Patient Protection and Affordable Care Act (PPACA) and the vision it contains for health care transformation. Along with sweeping changes in service delivery and payment structures, health care reform has championed concepts such as patient-centered care, integrated care, and wellness. Although these are not new ideas, their adaptation, in both ideology and service design has been accelerated in the context for reform. Indeed they are reaching a tipping point; the point where ideas gain wide acceptance and become influential trends. Although psychiatric mental health (PMH) nurses have been active in wellness, patient-centered care, and integrated care, at the current time they seem to be situated peripheral to these national trends. Increased presence of PMH nurses will facilitate their contribution to the development of these concepts within service structures and interventions. To increase knowledge and appreciation of PMH nurses' practice and unique perspective on these issues, leaders are needed who will connect and effectively communicate PMH nursing efforts to the broader health care arena. This article outlines the events that created a context for these three concepts (patient-centered care, wellness, and integrated care), and I suggest why they have reached a tipping point and discuss the need for greater PMH nursing presence in the American national dialog and the role of nursing leaders in facilitating these connections.

  17. The Power in Caring: Stepping in Where Others Don't Even Think to Tread.

    PubMed

    Denholm, Diana

    2015-01-01

    A caregiver, medical psychotherapist, and author of The Caregiving Wife's Handbook reveals that to move "from experience to empowerment," one must first recognize that his or her experience has value. Every caregiver has experienced something that calls out for improvement or change. Empowered acts can be as simple as monitoring the food choices hospitals offer our loved ones and reporting deficiencies. Yet, caregivers avoid discussing difficult issues and may be unable to communicate effectively about needs and/or solutions. Learned communication is the key to achieving what we wish, simultaneously creating the best possible relationships with those around us. Six easy steps, along with tips and tools, are given to help collaborate and create agreements.

  18. Masked ball: ethics, laws and financial contradictions in Hungarian health care.

    PubMed

    Szebik, Imre

    2003-01-01

    Corruption is a major problem in the societies of the post-communist Central European countries. Corruption in health care has some unique characteristics undermining the efficacy of and respect for Hungarian health care. One of the forms of corruption is tipping. This highly contested phenomenon is present in most of the patient/health professional's interactions in a sophisticated manner, raising serious ethical and legal dilemmas. The present paper analyzes tipping and other corruption-related factors, such as financial conflict of interest between industry and health care and argues that since ethical and legal considerations are often ignored in the country, patient care and clinical research are affected by these controversial issues to a great extent.

  19. 'On Your Feet to Earn Your Seat', a habit-based intervention to reduce sedentary behaviour in older adults: study protocol for a randomized controlled trial.

    PubMed

    Gardner, Benjamin; Thuné-Boyle, Ingela; Iliffe, Steve; Fox, Kenneth R; Jefferis, Barbara J; Hamer, Mark; Tyler, Nick; Wardle, Jane

    2014-09-20

    Many older adults are both highly sedentary (that is, spend considerable amounts of time sitting) and physically inactive (that is, do little physical activity). This protocol describes an exploratory trial of a theory-based behaviour change intervention in the form of a booklet outlining simple activities ('tips') designed both to reduce sedentary behaviour and to increase physical activity in older adults. The intervention is based on the 'habit formation' model, which proposes that consistent repetition leads to behaviour becoming automatic, sustaining activity gains over time. The intervention is being developed iteratively, in line with Medical Research Council complex intervention guidelines. Selection of activity tips was informed by semi-structured interviews and focus groups with older adults, and input from a multidisciplinary expert panel. An ongoing preliminary field test of acceptability among 25 older adults will inform further refinement. An exploratory randomized controlled trial will be conducted within a primary care setting, comparing the tips booklet with a control fact sheet. Retired, inactive and sedentary adults (n = 120) aged 60 to 74 years, with no physical impairments precluding light physical activity, will be recruited from general practices in north London, UK. The primary outcomes are recruitment and attrition rates. Secondary outcomes are changes in behaviour, habit, health and wellbeing over 12 weeks. Data will be used to inform study procedures for a future, larger-scale definitive randomized controlled trial. Current Controlled Trials ISRCTN47901994.

  20. A Rapid LC-HRMS Method for the Determination of Domoic Acid in Urine Using a Self-Assembly Pipette Tip Solid-Phase Extraction

    PubMed Central

    Zhang, Yiping; Chen, Dawei; Hong, Zhuan

    2015-01-01

    In this study, we developed a self-assembly pipette tip solid-phase extraction (PTSPE) method using a high molecular weight polymer material (PAX) as the adsorbent for the determination of domoic acid (DA) in human urine samples by liquid chromatography high-resolution mass spectrometry (LC-HRMS) analysis. The PTSPE cartridge, assembled by packing 9.1 mg of PAX as sorbent into a 200 μL pipette tip, showed high adsorption capacity for DA owing to the strong cationic properties of PAX. Compared with conventional SPE, the PTSPE is simple and fast, and shows some advantages in the aspects of less solvent consumption, low cost, the absence of the evaporation step, and short time requirement. All the parameters influencing the extraction efficiency such as pH, the amount of sorbent, the number of aspirating/dispensing cycles, and the type and volume of eluent in PTSPE were carefully investigated and optimized. Under the optimized conditions, the limit of detection (LOD) and limit of quantification (LOQ) values of DA were 0.12 μg/L and 0.37 μg/L respectively. The extraction recoveries of DA from the urine samples spiked at four different concentrations were in a range from 88.4% to 102.5%. The intra- and inter-day precisions varied from 2.1% to 7.6% and from 2.6% to 12.7%, respectively. The accuracy ranged from −1.9% to −7.4%. PMID:26729165

  1. Closed retrograde retrieval of the distal broken segment of femoral cannulated intramedullary nail using a ball-tipped guide wire.

    PubMed

    Metikala, Sreenivasulu; Mohammed, Riazuddin

    2011-07-01

    Extracting broken segments of intramedullay nails from long bones can be an operative challenge, particularly from the distal end. We report a case series where a simple and reproducible technique of extracting broken femoral cannulated nails using a ball-tipped guide wire is described. This closed technique involves no additional equipment or instruments. Eight patients who underwent the described method were included in the study. The technique involves using a standard plain guide wire passed through the cannulated distal broken nail segment after extraction of the proximal nail fragment. The plain guide wire is then advanced distally into the knee joint carefully under fluoroscopy imaging. Over this wire, a 5-millimeter (mm) cannulated large drill bit is used to create a track up to the distal broken nail segment. Through the small knee wound, a ball-tipped guide wire is passed, smooth end first, till the ball engages the end of the nail. The guide wire is then extracted along with the broken nail through the proximal wound. The method was successfully used in all eight patients for removal of broken cannulated intramedullary nail from the femoral canal without any complications. All patients underwent exchange nailing with successful bone union in six months. None of the patients had any problems at the knee joint at the final follow-up. We report a technique for successful extraction of the distal fragment of broken femoral intramedullary nails without additional surgical approaches.

  2. Homework for Parents -- Your Child's Back-To-School Health Checklist

    MedlinePlus

    ... Health & Safety Tips Campaigns Share this! EmergencyCareForYou » Health & Safety Tips » Homework for Parents — Your Child's Back-To-School Health Checklist Homework for Parents — Your Child's Back- ...

  3. Tips on Car Care & Safety for Deaf Drivers.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    Primarily intended for the deaf or hard of hearing driver, this booklet contains many tips useful to all drivers. It is divided into two sections: Signs of Car Trouble and What to Do, and Safe Driving Tips and Special Situations. The rationale for section 1 is that a hearing driver can often tell that his car is not running properly or that some…

  4. Spray Penetration with a Simple Fuel Injection Nozzle

    NASA Technical Reports Server (NTRS)

    Miller, Harold E; Beardsley, Edward G

    1926-01-01

    The purpose of the tests covered by this report was to obtain specific information on the rate of penetration of the spray from a simple injection nozzle, having a single orifice with a diameter of 0.015 inch when injecting into compressed gases. The results have shown that the effects of both chamber and fuel pressures on penetration are so marked that the study of sprays by means of high-speed photography or its equivalent is necessary if the effects are to be appreciated sufficiently to enable rational analysis. It was found for these tests that the negative acceleration of the spray tip is approximately proportional to the 1.5 power of the instantaneous velocity of the spray tip.

  5. Tips for Energy Savers In and Around the Home, On the Road, In the Marketplace. Don't Be Fuelish.

    ERIC Educational Resources Information Center

    Federal Energy Administration, Washington, DC.

    This pamphlet presents simple suggestions for energy conservation. Sections include: (1) In and around the home; (2) Using the family car; and (3) In the marketplace. The suggestions given are mostly common sense tips like dressing appropriately for either hot or cold weather, use electrical appliances and lights sparingly and at off-peak times,…

  6. Small, Lightweight Inspection Robot With 12 Degrees Of Freedom

    NASA Technical Reports Server (NTRS)

    Lee, Thomas S.; Ohm, Timothy R.; Hayati, Samad

    1996-01-01

    Small serpentine robot weighs only 6 lbs. and has link diameter of 1.5 in. Designed to perform inspections. Multiple degrees of freedom enables it to reach around obstacles and through small openings into simple or complexly shaped confined spaces to positions where difficult or impossible to perform inspections by other means. Fiber-optic borescope incorporated into robot arm, with inspection tip of borescope located at tip of arm. Borescope both conveys light along robot arm to illuminate scene inspected at tip and conveys image of scene back along robot arm to external imaging equipment.

  7. Digging the termite way: crowding simple robots to excavate ramification structures

    NASA Astrophysics Data System (ADS)

    Bardunias, Paul

    The complex ramification network that termites excavate in soil in search of resources has been shown to emerge from interactions between individuals during periodic crowding at the tips of tunnels. Excavation in these social insects is carried out by a rotation of termites removing soil from the tip of an expanding tunnel and depositing it back along the tunnel walls. Bristle bots, modified to either rock or turn on contact with soil in an artificial tunnel, were used to replicate this process. As in termites, congestion at tunnel tips leads to the widening and branching of tunnels.

  8. High-throughput, automated extraction of DNA and RNA from clinical samples using TruTip technology on common liquid handling robots.

    PubMed

    Holmberg, Rebecca C; Gindlesperger, Alissa; Stokes, Tinsley; Brady, Dane; Thakore, Nitu; Belgrader, Philip; Cooney, Christopher G; Chandler, Darrell P

    2013-06-11

    TruTip is a simple nucleic acid extraction technology whereby a porous, monolithic binding matrix is inserted into a pipette tip. The geometry of the monolith can be adapted for specific pipette tips ranging in volume from 1.0 to 5.0 ml. The large porosity of the monolith enables viscous or complex samples to readily pass through it with minimal fluidic backpressure. Bi-directional flow maximizes residence time between the monolith and sample, and enables large sample volumes to be processed within a single TruTip. The fundamental steps, irrespective of sample volume or TruTip geometry, include cell lysis, nucleic acid binding to the inner pores of the TruTip monolith, washing away unbound sample components and lysis buffers, and eluting purified and concentrated nucleic acids into an appropriate buffer. The attributes and adaptability of TruTip are demonstrated in three automated clinical sample processing protocols using an Eppendorf epMotion 5070, Hamilton STAR and STARplus liquid handling robots, including RNA isolation from nasopharyngeal aspirate, genomic DNA isolation from whole blood, and fetal DNA extraction and enrichment from large volumes of maternal plasma (respectively).

  9. Transverse vibration and buckling of a cantilevered beam with tip body under constant axial base acceleration

    NASA Technical Reports Server (NTRS)

    Storch, J.; Gates, S.

    1983-01-01

    The planar transverse bending behavior of a uniform cantilevered beam with rigid tip body subject to constant axial base acceleration was analyzed. The beam is inextensible and capable of small elastic transverse bending deformations only. Two classes of tip bodies are recognized: (1) mass centers located along the beam tip tangent line; and (2) mass centers with arbitrary offset towards the beam attachment point. The steady state response is studied for the beam end condition cases: free, tip mass, tip body with restricted mass center offset, and tip body with arbitrary mass center offset. The first three cases constitute classical Euler buckling problems, and the characteristic equation for the critical loads/accelerations are determined. For the last case a unique steady state solution exists. The free vibration response is examined for the two classes of tip body. The characteristic equation, eigenfunctions and their orthogonality properties are obtained for the case of restricted mass center offset. The vibration problem is nonhomogeneous for the case of arbitrary mass center offset. The exact solution is obtained as a sum of the steady state solution and a superposition of simple harmonic motions.

  10. Measurement and analysis of critical crack tip processes during fatigue crack growth

    NASA Technical Reports Server (NTRS)

    Davidson, D. L.; Hudak, S. J.; Dexter, R. J.

    1985-01-01

    The mechanics of fatigue crack growth under constant-amplitudes and variable-amplitude loading were examined. Critical loading histories involving relatively simple overload and overload/underload cycles were studied to provide a basic understanding of the underlying physical processes controlling crack growth. The material used for this study was 7091-T7E69, a powder metallurgy aluminum alloy. Local crack-tip parameters were measured at various times before, during, and after the overloads, these include crack-tip opening loads and displacements, and crack-tip strain fields. The latter were useed, in combination with the materials cyclic and monotonic stress-strain properties, to compute crack-tip residual stresses. The experimental results are also compared with analytical predictions obtained using the FAST-2 computer code. The sensitivity of the analytical model to constant-amplitude fatigue crack growth rate properties and to through-thickness constrain are studied.

  11. For Men: Tips for Good Health in Later Life

    MedlinePlus

    For Men: Tips for Good Health in Later Life Expert information from Healthcare Professionals Who Specialize in the Care ... Americans are living longer than ever, but American men still aren’t living as long as American ...

  12. Brakes: Traffic Safety Tips

    DOT National Transportation Integrated Search

    1996-01-01

    This fact sheet, NHTSA Facts: Summer 1996, describes traffic safety tips about brakes. It discusses drum brakes, disc brakes, and antilock braking systsms. It notes that there are government standards for brakes, and describes how to take care of bra...

  13. Engineering Novel Lab Devices Using 3D Printing and Microcontrollers.

    PubMed

    Courtemanche, Jean; King, Samson; Bouck, David

    2018-03-01

    The application of 3D printing and microcontrollers allows users to rapidly engineer novel hardware solutions useful in a laboratory environment. 3D printing is transformative as it enables the rapid fabrication of adapters, housings, jigs, and small structural elements. Microcontrollers allow for the creation of simple, inexpensive machines that receive input from one or more sensors to trigger a mechanical or electrical output. Bringing these technologies together, we have developed custom solutions that improve capabilities and reduce costs, errors, and human intervention. In this article, we describe three devices: JetLid, TipWaster, and Remote Monitoring Device (REMIND). JetLid employs a microcontroller and presence sensor to trigger a high-speed fan that reliably de-lids microtiter plates on a high-throughput screening system. TipWaster uses a presence sensor to activate an active tip waste chute when tips are ejected from a pipetting head. REMIND is a wireless, networked lab monitoring device. In its current implementation, it monitors the liquid level of waste collection vessels or bulk liquid reagent containers. The modularity of this device makes adaptation to other sensors (temperature, humidity, light/darkness, movement, etc.) relatively simple. These three devices illustrate how 3D printing and microcontrollers have enabled the process of rapidly turning ideas into useful devices.

  14. Progress Toward a Bulk Micromachined Tunneling Tip Microaccelerometer

    NASA Technical Reports Server (NTRS)

    Frank T. Hartley, Ben Dolgen, Paul M. Zavracky

    1995-01-01

    Ultrasensitive accelerometers are needed for microgravity measurement of orbital drag and active isolation systems. We have designed an accelerometer capable of measuring accelerations of the order of 10(i) g. A tunneling tip sensor can be used as a position sensor with a potential performance advantage of two orders of magnitude over capacitive sensors. In this paper, we disclose our progress in the fabrication and measurement of a bulk microaccelerometer which employs a tunneling tip. Fully assembled accelerometers consisting of four separate die have been fabricated. The device employs a unique folded spring system with a low spring constant. To protect the tunneling tip, we have employed electrostatic clamping. Stiction has not been observed, but the required clamping voltage is greater than expected. We have developed a simple model to analyze our results.

  15. Taking Care of Your Diabetes Means Taking Care of Your Heart (Tip Sheet)

    MedlinePlus

    ... Diabetes Means Taking Care of Your Heart Taking Care of Your Diabetes Means Taking Care of Your Heart Diabetes and Heart Disease For ... What you can do now Ask your health care team these questions: What can I do to ...

  16. Investigation of tip-depletion-induced fail in scanning capacitance microscopy for the determination of carrier type.

    PubMed

    Wang, Lin; Gautier, Brice; Sabac, Andrei; Bremond, Georges

    2017-03-01

    Scanning capacitance microscopy (SCM) was performed on an n-type Si multilayer structure doped by phosphorus whose concentration ranges from 2×10 17 to 2×10 19 cm -3 . Three types of tips were used, i.e. fresh Pt/Ir coated tip, worn Pt/Ir coated tip and non-coated commercial Si tip. The use of fresh Pt/Ir coated tips produces SCM result in good agreement with the doping profile including the correct identification of the carrier type. In contrast, a worn Pt/Ir coated tip which has lost its metal coating and a non-coated tip will fail to recognize successfully the carrier type for phosphorus dopant concentration above 8×10 18 cm -3 (identifying as p instead of n) due to the tip depletion effect. These results alert us to carefully interpret the SCM results, especially in the case for identification of carrier type inside the sample of interest which is unknown. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Wide angle near-field optical probes by reverse tube etching.

    PubMed

    Patanè, S; Cefalì, E; Arena, A; Gucciardi, P G; Allegrini, M

    2006-04-01

    We present a simple modification of the tube etching process for the fabrication of fiber probes for near-field optical microscopy. It increases the taper angle of the probe by a factor of two. The novelty is that the fiber is immersed in hydrofluoric acid and chemically etched in an upside-down geometry. The tip formation occurs inside the micrometer tube cavity formed by the polymeric jacket. By applying this approach, called reverse tube etching, to multimode fibers with 200/250 microm core/cladding diameter, we have fabricated tapered regions featuring high surface smoothness and average cone angles of approximately 30 degrees . A simple model based on the crucial role of the gravity in removing the etching products, explains the tip formation process.

  18. Family Caregivers and Transportation: A Few Survival Tips (Healthy Living Tips)

    MedlinePlus

    ... Plan ahead and allow plenty of time. • Show empathy and caring to your loved one. • Avoid rush ... INFORMATION ABOUT AOA U.S. DEPARTMENT OF HEALTH AND HUMAN SERVICES, ADMINISTRATION ON AGING, WASHINGTON, D.C. 20201 ...

  19. Cheaper, simpler, and better: tips for treating seniors with Parkinson disease.

    PubMed

    Ahlskog, J Eric

    2011-12-01

    Treatment of seniors with Parkinson disease is within the domain of primary care physicians and internists. A good working knowledge of carbidopa/levodopa principles should allow excellent care of most patients, at least during the early years of the disease. Even later, when levodopa responses become more complicated (eg, dyskinesias, motor fluctuations, insomnia, anxiety), levodopa adjustments may be all that is necessary. A dozen tips for optimizing treatment of Parkinson disease are discussed herein.

  20. Cheaper, Simpler, and Better: Tips for Treating Seniors With Parkinson Disease

    PubMed Central

    Ahlskog, J. Eric

    2011-01-01

    Treatment of seniors with Parkinson disease is within the domain of primary care physicians and internists. A good working knowledge of carbidopa/levodopa principles should allow excellent care of most patients, at least during the early years of the disease. Even later, when levodopa responses become more complicated (eg, dyskinesias, motor fluctuations, insomnia, anxiety), levodopa adjustments may be all that is necessary. A dozen tips for optimizing treatment of Parkinson disease are discussed herein. PMID:22134940

  1. In-place recalibration technique applied to a capacitance-type system for measuring rotor blade tip clearance

    NASA Technical Reports Server (NTRS)

    Barranger, J. P.

    1978-01-01

    The rotor blade tip clearance measurement system consists of a capacitance sensing probe with self contained tuning elements, a connecting coaxial cable, and remotely located electronics. Tests show that the accuracy of the system suffers from a strong dependence on probe tip temperature and humidity. A novel inplace recalibration technique was presented which partly overcomes this problem through a simple modification of the electronics that permits a scale factor correction. This technique, when applied to a commercial system significantly reduced errors under varying conditions of humidity and temperature. Equations were also found that characterize the important cable and probe design quantities.

  2. Near wakes of advanced turbopropellers

    NASA Technical Reports Server (NTRS)

    Hanson, D. B.; Patrick, W. P.

    1989-01-01

    The flow in the wake of a model single rotation Prop-Fan rotor operating in a wind tunnel was traversed with a hot-wire anemometer system designed to determine the 3 periodic velocity components. Special data acquisition and data reduction methods were required to deal with the high data frequency, narrow wakes, and large fluctuating air angles in the tip vortex region. The model tip helical Mach number was 1.17, simulating the cruise condition. Although the flow field is complex, flow features such as viscous velocity defects, vortex sheets, tip vortices, and propagating acoustic pulses are clearly identified with the aid of a simple analytical wake theory.

  3. Twelve tips for applying change models to curriculum design, development and delivery.

    PubMed

    McKimm, Judy; Jones, Paul Kneath

    2017-10-25

    Drawing primarily from business and management literature and the authors' experience, these 12 tips provide guidance to organizations, teams, and individuals involved in curriculum or program development at undergraduate, postgraduate, and continuing education levels. The tips are based around change models and approaches and can help underpin successful curriculum review, development, and delivery, as well as fostering appropriate educational innovation. A range of tools exist to support systematic program development and review, but even relatively simple changes need to take account of many factors, including the complexity of the environment, stakeholder engagement, cultural and psychological aspects, and the importance of followers.

  4. Hollow steel tips for reducing distal fiber burn-back during thulium fiber laser lithotripsy.

    PubMed

    Hutchens, Thomas C; Blackmon, Richard L; Irby, Pierce B; Fried, Nathaniel M

    2013-07-01

    The use of thulium fiber laser (TFL) as a potential alternative laser lithotripter to the clinical holmium:YAG laser is being studied. The TFL's Gaussian spatial beam profile provides efficient coupling of higher laser power into smaller core fibers without proximal fiber tip degradation. Smaller fiber diameters are more desirable, because they free up space in the single working channel of the ureteroscope for increased saline irrigation rates and allow maximum ureteroscope deflection. However, distal fiber tip degradation and "burn-back" increase as fiber diameter decreases due to both excessive temperatures and mechanical stress experienced during stone ablation. To eliminate fiber tip burn-back, the distal tip of a 150-μm core silica fiber was glued inside 1-cm-long steel tubing with fiber tip recessed 100, 250, 500, 1000, or 2000 μm inside the steel tubing to create the hollow-tip fiber. TFL pulse energy of 34 mJ with 500-μs pulse duration and 150-Hz pulse rate was delivered through the hollow-tip fibers in contact with human calcium oxalate monohydrate urinary stones during ex vivo studies. Significant fiber tip burn-back and degradation was observed for bare 150-μm core-diameter fibers. However, hollow steel tip fibers experienced minimal fiber burn-back without compromising stone ablation rates. A simple, robust, compact, and inexpensive hollow fiber tip design was characterized for minimizing distal fiber burn-back during the TFL lithotripsy. Although an increase in stone retropulsion was observed, potential integration of the hollow fiber tip into a stone basket may provide rapid stone vaporization, while minimizing retropulsion.

  5. Taking Care of Yourself - Advanced Cancer and Caregivers

    Cancer.gov

    Caring for someone with advanced cancer brings new challenges and concerns. It's important to take care of yourself and reach out for help. Find tips specific to caregivers of patients with advanced cancer.

  6. Lewy Body Dementia Glossary

    MedlinePlus

    ... go during the day for activities, socializing, education, physical therapy and health care. These services can TIP: Definitions ... care services, such as disease management, nursing care, physical therapy, occupational therapy, and speech therapy. Assistance with every ...

  7. Children with Special Health Care Needs

    MedlinePlus

    ... to the Hospital Heroes On Medicine's Front Line Observation Emergency Care Fact Sheet Health & Safety Tips Campaigns ... to all caregivers of children, such as babysitters, teachers, and school nurses. Resources Emergency Care For You ...

  8. Designing a Simple Apparatus for Measuring Kinematic Variables

    ERIC Educational Resources Information Center

    Temiz, Burak Kagan

    2014-01-01

    This study was conducted to develop a simple and inexpensive experimental apparatus that can measure the position of an object moving along a straight line at certain time intervals. For the construction of the apparatus, a battery-powered toy car, a fine-tipped paint brush, gouache (or watercolour) paint and paper tape were used. The working…

  9. Tips, Tricks & Techniques: Creating & Teaching with Simple Animation: Making Biology Instruction Come Alive

    ERIC Educational Resources Information Center

    Zanin, Mary K. B.

    2015-01-01

    Over the years, many of my students have reported that they enjoy lectures that include short, simple animations. To keep students engaged, I have developed a small set of teaching animations using PowerPoint and Camtasia Studio software packages. A survey of students who learned four difficult topics with traditional written lessons and with…

  10. Fiber-optic Singlet Oxygen [1O2 (1Δg)] Generator Device Serving as a Point Selective Sterilizer

    PubMed Central

    Aebisher, David; Zamadar, Matibur; Mahendran, Adaickapillai; Ghosh, Goutam; McEntee, Catherine; Greer, Alexander

    2016-01-01

    Traditionally, Type II heterogeneous photo-oxidations produce singlet oxygen via external irradiation of a sensitizer and external supply of ground-state oxygen. A potential improvement is reported here. A hollow-core fiber-optic device was developed with an “internal” supply of light and flowing oxygen, and a porous photosensitizer-end capped configuration. Singlet oxygen was delivered through the fiber tip. The singlet oxygen steady-state concentration in the immediate vicinity of the probe tip was ca 20 fM by N-benzoyl-DL-methionine trapping. The device is portable and the singlet oxygen-generating tip is maneuverable, which opened the door to simple disinfectant studies. Complete Escherichia coli inactivation was observed in 2 h when the singlet oxygen sensitizing probe tip was immersed in 0.1 mL aqueous samples of 0.1–4.4 × 107 cells. Photobleaching of the probe tip occurred after ca 12 h of use, requiring baking and sensitizer reloading steps for reuse. PMID:20497367

  11. Using a sharp metal tip to control the polarization and direction of emission from a quantum dot.

    PubMed

    Ghimire, Anil; Shafran, Eyal; Gerton, Jordan M

    2014-09-24

    Optical antennas can be used to manipulate the direction and polarization of radiation from an emitter. Usually, these metallic nanostructures utilize localized plasmon resonances to generate highly directional and strongly polarized emission, which is determined predominantly by the antenna geometry alone, and is thus not easily tuned. Here we show experimentally that the emission polarization can be manipulated using a simple, nonresonant scanning probe consisting of the sharp metallic tip of an atomic force microscope; finite element simulations reveal that the emission simultaneously becomes highly directional. Together, the measurements and simulations demonstrate that interference between light emitted directly into the far field with that elastically scattered from the tip apex in the near field is responsible for this control over polarization and directionality. Due to the relatively weak emitter-tip coupling, the tip must be positioned very precisely near the emitter, but this weak coupling also leads to highly tunable emission properties with a similar degree of polarization and directionality compared to resonant antennas.

  12. Carbon Nanotube Based Nano-Electro-Mechanical Systems (NEMS)

    NASA Technical Reports Server (NTRS)

    Han, Jie; Dai, Hongjie; Saini, Subhash

    1998-01-01

    Carbon nanotubes (CNT) enable nanoelectromechanical systems (NEMS) because of their inherent nanostructure, intrinsic electric conductivity and mechanical resilience. The collaborative work between Stanford (experiment) and NASA Ames (theory and simulation) has made progress in two types of CNT based NEMS for nanoelectronics and sensor applications. The CNT tipped scanning probe microscopy (SPM) is a NEMS in which CNT tips are used for nanoscale probing, imaging and manipulating. It showed great improvement in probing surfaces and biological systems over conventional tips. We have recently applied it to write (lithography) and read (image) uniform SiO2 lines on large Si surface area at speed up to 0.5 mm per s. Preliminary work using approximately 10 nm multiwall nanotube tips produced approximately 10 nm structures and showed that the CNT tips didn't wear down when crashed as conventional tips often do. This presents a solution to the long standing tip-wear problem in SPM nanolithography. We have also explored potential of CNT tips in imaging DNA in water. Preliminary experiment using 10 nm CNT tips reached 5 nm resolution. The 1 nm nanolithography and 1 nm DNA imaging can be expected by using approximately 1 nm CNT tips. In contrast to CNT tipped SPM, we also fabricated CNT devices on silicon wafer in which CNTs connect patterned metallic lines on SiO2/Si by a simple chemical vapor deposition process. Using conventional lithography for silicon wafer, we have been able to obtain CNT based transistors and sensors. Investigations of the CNT NEMS as physical, biological and chemical sensors are in progress and will be discussed.

  13. Cavitation and Wake Structure of Unsteady Tip Vortex Flows

    DTIC Science & Technology

    1992-12-10

    wake structure generated by three-dimensional lifting surfaces. No longer can the wake be modeled as a simple horseshoe vortex structure with the tip...first initiates. -13- Z Strtn vortex "~Bound vortex "’ ; b Wake 2 Figure 1.5 Far-Field Horseshoe Model of a Finite Wing This figure shows a finite wing...Figure 1.11 Simplified Illustration of Wake Structure Behind an Oscillating Wing This schematic shows a simplified model of the trailing vortex

  14. Modelling preventive effectiveness to estimate the equity tipping point: at what coverage can individual preventive interventions reduce socioeconomic disparities in diabetes risk?

    PubMed

    Manuel, D G; Ho, T H; Harper, S; Anderson, G M; Lynch, J; Rosella, L C

    2014-07-01

    Most individual preventive therapies potentially narrow or widen health disparities depending on the difference in community effectiveness across socioeconomic position (SEP). The equity tipping point (defined as the point at which health disparities become larger) can be calculated by varying components of community effectiveness such as baseline risk of disease, intervention coverage and/or intervention efficacy across SEP. We used a simple modelling approach to estimate the community effectiveness of diabetes prevention across SEP in Canada under different scenarios of intervention coverage. Five-year baseline diabetes risk differed between the lowest and highest income groups by 1.76%. Assuming complete coverage across all income groups, the difference was reduced to 0.90% (144 000 cases prevented) with lifestyle interventions and 1.24% (88 100 cases prevented) with pharmacotherapy. The equity tipping point was estimated to be a coverage difference of 30% for preventive interventions (100% and 70% coverage among the highest and lowest income earners, respectively). Disparities in diabetes risk could be measurably reduced if existing interventions were equally adopted across SEP. However, disparities in coverage could lead to increased inequity in risk. Simple modelling approaches can be used to examine the community effectiveness of individual preventive interventions and their potential to reduce (or increase) disparities. The equity tipping point can be used as a critical threshold for disparities analyses.

  15. Polymeric ionic liquid-based portable tip microextraction device for on-site sample preparation of water samples.

    PubMed

    Chen, Lei; Pei, Junxian; Huang, Xiaojia; Lu, Min

    2018-06-05

    On-site sample preparation is highly desired because it avoids the transportation of large-volume samples and ensures the accuracy of the analytical results. In this work, a portable prototype of tip microextraction device (TMD) was designed and developed for on-site sample pretreatment. The assembly procedure of TMD is quite simple. Firstly, polymeric ionic liquid (PIL)-based adsorbent was in-situ prepared in a pipette tip. After that, the tip was connected with a syringe which was driven by a bidirectional motor. The flow rates in adsorption and desorption steps were controlled accurately by the motor. To evaluate the practicability of the developed device, the TMD was used to on-site sample preparation of waters and combined with high-performance liquid chromatography with diode array detection to measure trace estrogens in water samples. Under the most favorable conditions, the limits of detection (LODs, S/N = 3) for the target analytes were in the range of 4.9-22 ng/L, with good coefficients of determination. Confirmatory study well evidences that the extraction performance of TMD is comparable to that of the traditional laboratory solid-phase extraction process, but the proposed TMD is more simple and convenient. At the same time, the TMD avoids complicated sampling and transferring steps of large-volume water samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Morphology dependent near-field response in atomistic plasmonic nanocavities.

    PubMed

    Chen, Xing; Jensen, Lasse

    2018-06-21

    In this work we examine how the atomistic morphologies of plasmonic dimers control the near-field response by using an atomistic electrodynamics model. At large separations, the field enhancement in the junction follows a simple inverse power law as a function of the gap separation, which agrees with classical antenna theory. However, when the separations are smaller than 0.8 nm, the so-called quantum size regime, the field enhancement is screened and thus deviates from the simple power law. Our results show that the threshold distance for the deviation depends on the specific morphology of the junction. The near field in the junction can be localized to an area of less than 1 nm2 in the presence of an atomically sharp tip, but the separation distances leading to a large confinement of near field depend strongly on the specific atomistic configuration. More importantly, the highly confined fields lead to large field gradients particularly in a tip-to-surface junction, which indicates that such a plasmonic structure favors observing strong field gradient effects in near-field spectroscopy. We find that for atomically sharp tips the field gradient becomes significant and depends strongly on the local morphology of a tip. We expect our findings to be crucial for understanding the origin of high-resolution near-field spectroscopy and for manipulating optical cavities through atomic structures in the strongly coupled plasmonic systems.

  17. [Over projected tip].

    PubMed

    Duron, J-B; Nguyen, P S; Levet, Y; Bardot, J; Aiach, G

    2014-12-01

    Overprojected tip is a pretty usual request not easy to manage. Preop analysis is crucial in order to evaluate tip support and skin thickness and ability to retract. For example, if the skin is very thick and has poor chance to retract, the surgeon should be very careful in the tip projection decreasing to avoid a skin pollybeak deformity. In such cases, he has to analyze the facial proportions, especially other areas projection (radix, dorsum and chin) and think about augmenting them to balance the profile rather than decreasing tip projection. Correction should always be conducted incrementally, starting with weakening the tip support mechanisms and, only if necessary, continue with alar cartilage interruption. This can be performed on many areas (lateral cruras, domes, medial cruras) and with several techniques (resection or interruption+overlapping). Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  18. On the origin of amplitude reduction mechanism in tapping mode atomic force microscopy

    NASA Astrophysics Data System (ADS)

    Keyvani, Aliasghar; Sadeghian, Hamed; Goosen, Hans; van Keulen, Fred

    2018-04-01

    The origin of amplitude reduction in Tapping Mode Atomic Force Microscopy (TM-AFM) is typically attributed to the shift in resonance frequency of the cantilever due to the nonlinear tip-sample interactions. In this paper, we present a different insight into the same problem which, besides explaining the amplitude reduction mechanism, provides a simple reasoning for the relationship between tip-sample interactions and operation parameters (amplitude and frequency). The proposed formulation, which attributes the amplitude reduction to an interference between the tip-sample and dither force, only deals with the linear part of the system; however, it fully agrees with experimental results and numerical solutions of the full nonlinear model of TM-AFM.

  19. Finding Health Care Services

    Cancer.gov

    If you have been diagnosed with cancer, finding a doctor and treatment hospital for your cancer care is an important step to getting the best treatment possible. Learn tips for choosing a doctor and treatment facility to manage your cancer care.

  20. Web-Based Tailored Intervention for Preparation of Parents and Children for Outpatient Surgery (WebTIPS): Formative Evaluation and Randomized Controlled Trial

    PubMed Central

    Fortier, Michelle A.; Bunzli, Elizabeth; Walthall, Jessica; Olshansky, Ellen; Saadat, Haleh; Santistevan, Ricci; Mayes, Linda; Kain, Zeev N.

    2015-01-01

    Background The purpose of this two-phase project was to conduct formative evaluation and test the preliminary efficacy of a newly developed web-based, tailored behavioral preparation program (WebTIPS) for children undergoing outpatient surgery and their parents Methods Phase I enrolled 13 children aged 2–7 years undergoing outpatient elective surgery and their parents for formative evaluation of WebTIPS. Parent participation focus groups which are common in qualitative research and are a method of asking research participants about their perceptions and attitudes regarding a product or concept. In phase II, children age 2–7 years in two medical centers were randomly assigned to receive the WebTIPS program (n = 38) compared to children receiving standard of care (n = 44). The primary outcome of phase II was child and parent preoperative anxiety. Results In phase I, parents reported WebTIPS to be both helpful (p < 0.001) and easy to use (p < 0.001). In phase II, children in the WebTIPS group (36.2 ± 14.1) were less anxious than children in the standard of care group (46.0 ± 19.0) at entrance to the operating room (p = 0.02; Cohen’s d = 0.59) and introduction of the anesthesia mask (43.5 ± 21.7 vs. 57.0 ± 21.2, respectively, p = 0.01; Cohen’s d = 0.63). Parents in the WebTIPS group (32.1 ± 7.4) also experienced less anxiety compared to parents in the control group (36.8 ± 7.1) in the preoperative holding area (p = 0.004; Cohen’s d = 0.65). Conclusions WebTIPS was well received by parents and children and led to reductions in preoperative anxiety. PMID:25790213

  1. Orthodontics for the dog. Treatment methods.

    PubMed

    Ross, D L

    1986-09-01

    This article considers the prevention of orthodontic problems, occlusal adjustments, simple tooth movements, rotational techniques, tipping problems, adjustment of crown height, descriptions of common orthodontic appliances, and problems associated with therapy.

  2. Top 10 Tips for Using Advance Care Planning Codes in Palliative Medicine and Beyond.

    PubMed

    Jones, Christopher A; Acevedo, Jean; Bull, Janet; Kamal, Arif H

    2016-12-01

    Although recommended for all persons with serious illness, advance care planning (ACP) has historically been a charitable clinical service. Inadequate or unreliable provisions for reimbursement, among other barriers, have spurred a gap between the evidence demonstrating the importance of timely ACP and recognition by payers for its delivery. 1 For the first time, healthcare is experiencing a dramatic shift in billing codes that support increased care management and care coordination. ACP, chronic care management, and transitional care management codes are examples of this newer recognition of the value of these types of services. ACP discussions are an integral component of comprehensive, high-quality palliative care delivery. The advent of reimbursement mechanisms to recognize these services has an enormous potential to impact palliative care program sustainability and growth. In this article, we highlight 10 tips to effectively using the new ACP codes reimbursable under Medicare. The importance of documentation, proper billing, and nuances regarding coding is addressed.

  3. Top 10 Tips for Using Advance Care Planning Codes in Palliative Medicine and Beyond

    PubMed Central

    Acevedo, Jean; Bull, Janet; Kamal, Arif H.

    2016-01-01

    Abstract Although recommended for all persons with serious illness, advance care planning (ACP) has historically been a charitable clinical service. Inadequate or unreliable provisions for reimbursement, among other barriers, have spurred a gap between the evidence demonstrating the importance of timely ACP and recognition by payers for its delivery.1 For the first time, healthcare is experiencing a dramatic shift in billing codes that support increased care management and care coordination. ACP, chronic care management, and transitional care management codes are examples of this newer recognition of the value of these types of services. ACP discussions are an integral component of comprehensive, high-quality palliative care delivery. The advent of reimbursement mechanisms to recognize these services has an enormous potential to impact palliative care program sustainability and growth. In this article, we highlight 10 tips to effectively using the new ACP codes reimbursable under Medicare. The importance of documentation, proper billing, and nuances regarding coding is addressed. PMID:27682147

  4. Ten Things Lesbians Should Discuss with Their Health Care Provider

    MedlinePlus

    ... for high blood pressure, cholesterol problems, and diabetes. Health care providers can also offer tips on quitting smoking, ... lesbians experience violence in their intimate relationships. However, health care providers do not ask lesbians about intimate partner ...

  5. Fabrication of near-field optical apertures in aluminium by a highly selective corrosion process in the evanescent field.

    PubMed

    Haefliger, D; Stemmer, A

    2003-03-01

    A simple, one-step process to fabricate high-quality apertures for scanning near-field optical microscope probes based on aluminium-coated silicon nitride cantilevers is presented. A thin evanescent optical field at a glass-water interface was used to heat the aluminium at the tip apex due to light absorption. The heat induced a breakdown of the passivating oxide layer and local corrosion of the metal, which selectively exposed the front-most part of the probe tip from the aluminium. Apertures with a protruding silicon nitride tip up to 72 nm in height were fabricated. The height of the protrusion was controlled by the extent of the evanescent field, whereas the diameter depended on the geometry of the probe substrate. The corrosion process proved to be self-terminating, yielding highly reproducible tip heights. Near-field optical resolution in a transmission mode of 85 nm was demonstrated.

  6. Study of mechanical behavior of AFM silicon tips under mechanical load

    NASA Astrophysics Data System (ADS)

    Kopycinska-Mueller, M.; Gluch, J.; Köhler, B.

    2016-11-01

    In this paper we address critical issues concerning calibration of AFM based methods used for nanoscale mechanical characterization of materials. It has been shown that calibration approaches based on macroscopic models for contact mechanics may yield excellent results in terms of the indentation modulus of the sample, but fail to provide a comprehensive and actual information concerning the tip-sample contact radius or the mechanical properties of the tip. Explanations for the severely reduced indentation modulus of the tip included the inadequacies of the models used for calculations of the tip-sample contact stiffness, discrepancies in the actual and ideal shape of the tip, presence of the amorphous silicon phase within the silicon tip, as well as negligence of the actual size of the stress field created in the tip during elastic interactions. To clarify these issues, we investigated the influence of the mechanical load applied to four AFM silicon tips on their crystalline state by exposing them to systematically increasing loads, evaluating the character of the tip-sample interactions via the load-unload stiffness curves, and assessing the state of the tips from HR-TEM images. The results presented in this paper were obtained in a series of relatively simple and basic atomic force acoustic microscopy (AFAM) experiments. The novel combination of TEM imaging of the AFM tips with the analysis of the load-unload stiffness curves gave us a detailed insight into their mechanical behavior under load conditions. We were able to identify the limits for the elastic interactions, as well as the hallmarks for phase transformation and dislocation formation and movement. The comparison of the physical dimensions of the AFM tips, geometry parameters determined from the values of the contact stiffness, and the information on the crystalline state of the tips allowed us a better understanding of the nanoscale contact.

  7. Twelve tips for "flipping" the classroom.

    PubMed

    Moffett, Jennifer

    2015-04-01

    The flipped classroom is a pedagogical model in which the typical lecture and homework elements of a course are reversed. The following tips outline the steps involved in making a successful transition to a flipped classroom approach. The tips are based on the available literature alongside the author's experience of using the approach in a medical education setting. Flipping a classroom has a number of potential benefits, for example increased educator-student interaction, but must be planned and implemented carefully to support effective learning.

  8. Long-Term Follow-Up After Successful Transjugular Intrahepatic Portosystemic Shunt Placement in a Pediatric Patient with Budd-Chiari Syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carnevale, Francisco Cesar, E-mail: fcarnevale@uol.com.br; Szejnfeld, Denis, E-mail: denis@cura.com.br; Moreira, Airton Mota

    Orthotopic liver transplantation is the standard of care in patients with Budd-Chiari syndrome (BCS), and transjugular intrahepatic portosystemic shunt (TIPS) has become an important adjunct procedure while the patient is waiting for a liver. No long-term follow up of TIPS in BCS patients has been published in children. We report successful 10-year follow-up of a child with BCS and iatrogenic TIPS dysfunction caused by oral contraceptive use.

  9. Get Screened

    MedlinePlus

    ... these tips on choosing a doctor you can trust . Make sure you get the results from every ... The Affordable Care Act , the health care reform law passed in 2010, requires most insurance plans to ...

  10. Find a Massage Therapist

    MedlinePlus

    ... tools to market your massage practice, expand your business and improve your professional growth. Explore Career Guidance » Take Care of Your Practice Marketing Tools Client Experience/Intake Forms Self-Care Tips ...

  11. Isolated Capsulorhexis Flap Technique in Femtosecond Laser-Assisted Cataract Surgery to Protect the Corneal Endothelial Cells.

    PubMed

    Li, Shaowei; Chen, Xu; Zhao, Jun; Xu, Man; Yu, Zhouxing

    2017-12-18

    To present a novel technique that using capsulorhexis flap to protect corneal endothelial cells during femtosecond laser-assisted cataract surgery. During the procedure, an isolated capsulorhexis flap was used to lift it up carefully by using OVD until the flap attached to the corneal inner layer. It kept steady during the phaco phase, and been removed by I/A tip after intraocular lens implantation. In our pilot study, the damage to the corneal endothelial cells from the phacoemulsification procedure were no more than the traditional phaco procedure, even femtosecond laser assisted cataract surgery. Isolated capsulorhexis flap technique initiate a new approach to protect the endothelial cell. It is a simple technique with a short learning curve, but still need a further investigation to prove the protection of corneal endothelial cells.

  12. Fall Prevention: Simple Tips to Prevent Falls

    MedlinePlus

    ... she can help you brainstorm other fall-prevention strategies. Some solutions are easily installed and relatively inexpensive. Others may require professional help or a larger investment. If you're concerned about the cost, remember ...

  13. Principles and Applications of the qPlus Sensor

    NASA Astrophysics Data System (ADS)

    Giessibl, Franz J.

    The concept of the atomic force microscope (AFM) is a very simple one: map the surface of a sample by a sharp probe that scans over the surface similar to the finger of a blind person that reads Braille characters. In AFM, the role of that finger is taken by the probe tip that senses the presence of the sample surface by detecting the force between the tip of the probe and a sample. The qPlus sensor is a self sensing cantilever based on a quartz tuning fork that supplements the traditional microfabricated cantilevers made of silicon. Quartz tuning forks are used in the watch industry in quantities of billions annually, with the positive effects on quality and perfection. Three properties of these quartz-based sensors simplify the AFM significantly: (1) the piezoelectricity of quartz allows simple self sensing, (2) the mechanical properties of quartz show very small variations with temperature, and (3) the given stiffness of many quartz tuning forks is close to the ideal stiffness of cantilevers. The key properties of the qPlus sensor are a large stiffness that allows small amplitude operation, the large size that allows to mount single-crystal probe tips, and the self-sensing piezoelectric detection mechanism.

  14. Evidence on Tips for Supporting Reading Skills at Home

    ERIC Educational Resources Information Center

    What Works Clearinghouse, 2018

    2018-01-01

    This document begins by providing four tips parents and care takers can use to supporting childrens' reading skills at home: (1) Have conversations before, during, and after reading together; (2) Help children learn how to break sentences into words and words into syllables; (3) Help children sound out words smoothly; and (4) Model reading…

  15. Questions for Your Prospective Massage Therapist

    MedlinePlus

    ... tools to market your massage practice, expand your business and improve your professional growth. Explore Career Guidance » Take Care of Your Practice Marketing Tools Client Experience/Intake Forms Self-Care Tips ...

  16. Tips for Daily Life

    MedlinePlus

    ... for Care Costs Paying for Care Insurance Social Security Disability Medicare Medicare Part D Benefits Medicaid Tax ... Ave. Floor 17 Chicago, IL 60601 Contact Us Security and Privacy Policy Copyrights and Reprints Pressroom Select ...

  17. A comparative study of epidural catheter colonization and infection in Intensive Care Unit and wards in a Tertiary Care Public Hospital.

    PubMed

    Harde, Minal; Bhadade, Rakesh; Iyer, Hemlata; Jatale, Amol; Tiwatne, Sagar

    2016-02-01

    Infection is a potentially serious complication of epidural analgesia and with an increase in its use in wards there is a necessity to demonstrate its safety. We aimed to compare the incidence of colonization of epidural catheters retained for short duration (for 48 h) postoperative analgesia in postanesthesia care unit and wards. It was a prospective observational study done in a tertiary care teaching public hospital over a period of 2 years and included 400 patients with 200 each belonged to two groups PACU and ward. We also studied epidural tip culture pattern, skin swab culture at the entry point of the catheter, their relation to each other and whether colonization is equivalent to infection. Data were analyzed using statistical software GraphPad. Overall positive tip culture was 6% (24), of them 7% (14) were from PACU and 5% (10) were from ward (P = 0.5285). Positive skin swab culture was 38% (150), of them 20% (80) were from PACU and 18% (70) were from ward (P = 0.3526). The relation between positive tip culture and positive skin swab culture in same patients is extremely significant showing a strong linear relationship (95% confidence interval = 0.1053-0.2289). The most common microorganism isolated was Staphylococcus epidermidis. No patient had signs of local or epidural infection. There is no difference in the incidence of epidural catheter tip culture and skin swab culture of patients from the general ward and PACU. Epidural analgesia can be administered safely for 48 h in general wards without added risk of infection. The presence of positive tip culture is not a predictor of epidural space infection, and colonization is not equivalent to infection; hence, routine culture is not needed. Bacterial migration from the skin along the epidural track is the most common mode of bacterial colonization; hence, strict asepsis is necessary.

  18. Development and testing of tip devices for horizontal axis wind turbines

    NASA Technical Reports Server (NTRS)

    Gyatt, G. W.; Lissaman, P. B. S.

    1985-01-01

    A theoretical and field experimental program has been carried out to investigate the use of tip devices on horizontal axis wind turbine rotors. The objective was to improve performance by the reduction of tip losses. While power output can always be increased by a simple radial tip extension, such a modification also results in an increased gale load both because of the extra projected area and longer moment arm. Tip devices have the potential to increase power output without such a structural penalty. A vortex lattice computer model was used to optimize three basic tip configuration types for a 25 kW stall limited commercial wind turbine. The types were a change in tip planform, and a single-element and double-element nonplanar tip extension (winglets). A complete data acquisition system was developed which recorded three wind speed components, ambient pressure, temperature, and turbine output. The system operated unattended and could perform real-time processing of the data, displaying the measured power curve as data accumulated in either a bin sort mode or polynomial curve fit. Approximately 270 hr of perormance data were collected over a three-month period. The sampling interval was 2.4 sec; thrus over 400,000 raw data points were logged. Results for each of the three new tip devices, compared with the original tip, showed a small decrease (of the order of 1 kW) in power output over the measured range of wind speeds from cut-in at about 4 m/s to over 20 m/s, well into the stall limiting region. Changes in orientation and angle-of-attack of the winglets were not made. For aircraft wing tip devices, favorable tip shapes have been reported and it is likely that the tip devices tested in this program did not improve rotor performance because they were not optimally adjusted.

  19. Tidal Energy Resource Assessment for McMurdo Station, Antarctica

    DTIC Science & Technology

    2016-12-01

    highest power coefficient possible, only to provide a high- fidelity data set for a simple geometry turbine model at reasonably high blade chord Reynolds...highest power coefficient possible, only to provide a high-fidelity data set for a simple geometry turbine model at reasonably high blade chord...Reynolds numbers. Tip speed ratio, , is defined as = where is the anglular velocity of the blade and is the

  20. Alveolar Ridge Split Technique Using Piezosurgery with Specially Designed Tips

    PubMed Central

    Moro, Alessandro; Foresta, Enrico; Falchi, Marco; De Angelis, Paolo; D'Amato, Giuseppe; Pelo, Sandro

    2017-01-01

    The treatment of patients with atrophic ridge who need prosthetic rehabilitation is a common problem in oral and maxillofacial surgery. Among the various techniques introduced for the expansion of alveolar ridges with a horizontal bone deficit is the alveolar ridge split technique. The aim of this article is to give a description of some new tips that have been specifically designed for the treatment of atrophic ridges with transversal bone deficit. A two-step piezosurgical split technique is also described, based on specific osteotomies of the vestibular cortex and the use of a mandibular ramus graft as interpositional graft. A total of 15 patients were treated with the proposed new tips by our department. All the expanded areas were successful in providing an adequate width and height to insert implants according to the prosthetic plan and the proposed tips allowed obtaining the most from the alveolar ridge split technique and piezosurgery. These tips have made alveolar ridge split technique simple, safe, and effective for the treatment of horizontal and vertical bone defects. Furthermore the proposed piezosurgical split technique allows obtaining horizontal and vertical bone augmentation. PMID:28246596

  1. Conical Tungsten Tips as Substrates for the Preparation of Ultramicroelectrodes

    PubMed Central

    Hermans, Andre; Wightman, R. Mark

    2008-01-01

    Here we describe a simple method to prepare voltammetric microelectrodes using tungsten wires as a substrate. Tungsten wires have high tensile modulus and enable the fabrication of electrodes that have small dimensions overall while retaining rigidity. In this work, 125 μm tungsten wires with a conical tip were employed. For the preparation of gold or platinum ultramicroelectrodes, commercial tungsten microelectrodes, completely insulated except at the tip, were used as substrates. Following removal of oxides from the exposed tungsten, platinum or gold was electroplated yielding surfaces with an electroactive area of between 1×10−6 cm2 to 2×10−6 cm2. Carbon surfaces on the etched tip of tungsten microwires were prepared by coating with photoresist followed by pyrolysis. The entire electrode was then insulated with Epoxylite except the tip yielding an exposed carbon surface with an area of around 4×10−6 cm2 to 6×10−6 cm2. All three types of ultramicroelectrodes fabricated on the tungsten wire had similar electrochemical behavior to electrodes fabricated from wires or fibers insulated with glass tubes. PMID:17129002

  2. Alveolar Ridge Split Technique Using Piezosurgery with Specially Designed Tips.

    PubMed

    Moro, Alessandro; Gasparini, Giulio; Foresta, Enrico; Saponaro, Gianmarco; Falchi, Marco; Cardarelli, Lorenzo; De Angelis, Paolo; Forcione, Mario; Garagiola, Umberto; D'Amato, Giuseppe; Pelo, Sandro

    2017-01-01

    The treatment of patients with atrophic ridge who need prosthetic rehabilitation is a common problem in oral and maxillofacial surgery. Among the various techniques introduced for the expansion of alveolar ridges with a horizontal bone deficit is the alveolar ridge split technique. The aim of this article is to give a description of some new tips that have been specifically designed for the treatment of atrophic ridges with transversal bone deficit. A two-step piezosurgical split technique is also described, based on specific osteotomies of the vestibular cortex and the use of a mandibular ramus graft as interpositional graft. A total of 15 patients were treated with the proposed new tips by our department. All the expanded areas were successful in providing an adequate width and height to insert implants according to the prosthetic plan and the proposed tips allowed obtaining the most from the alveolar ridge split technique and piezosurgery. These tips have made alveolar ridge split technique simple, safe, and effective for the treatment of horizontal and vertical bone defects. Furthermore the proposed piezosurgical split technique allows obtaining horizontal and vertical bone augmentation.

  3. Augmented reality guidance system for peripheral nerve blocks

    NASA Astrophysics Data System (ADS)

    Wedlake, Chris; Moore, John; Rachinsky, Maxim; Bainbridge, Daniel; Wiles, Andrew D.; Peters, Terry M.

    2010-02-01

    Peripheral nerve block treatments are ubiquitous in hospitals and pain clinics worldwide. State of the art techniques use ultrasound (US) guidance and/or electrical stimulation to verify needle tip location. However, problems such as needle-US beam alignment, poor echogenicity of block needles and US beam thickness can make it difficult for the anesthetist to know the exact needle tip location. Inaccurate therapy delivery raises obvious safety and efficacy issues. We have developed and evaluated a needle guidance system that makes use of a magnetic tracking system (MTS) to provide an augmented reality (AR) guidance platform to accurately localize the needle tip as well as its projected trajectory. Five anesthetists and five novices performed simulated nerve block deliveries in a polyvinyl alcohol phantom to compare needle guidance under US alone to US placed in our AR environment. Our phantom study demonstrated a decrease in targeting attempts, decrease in contacting of critical structures, and an increase in accuracy of 0.68 mm compared to 1.34mm RMS in US guidance alone. Currently, the MTS uses 18 and 21 gauge hypodermic needles with a 5 degree of freedom sensor located at the needle tip. These needles can only be sterilized using an ethylene oxide process. In the interest of providing clinicians with a simple and efficient guidance system, we also evaluated attaching the sensor at the needle hub as a simple clip-on device. To do this, we simultaneously performed a needle bending study to assess the reliability of a hub-based sensor.

  4. Using natural archives to detect climate and environmental tipping points in the Earth System

    NASA Astrophysics Data System (ADS)

    Thomas, Zoë A.

    2016-11-01

    'Tipping points' in the Earth system are characterised by a nonlinear response to gradual forcing, and may have severe and wide-ranging impacts. Many abrupt events result from simple underlying system dynamics termed 'critical transitions' or 'bifurcations'. One of the best ways to identify and potentially predict threshold behaviour in the climate system is through analysis of natural ('palaeo') archives. Specifically, on the approach to a tipping point, early warning signals can be detected as characteristic fluctuations in a time series as a system loses stability. Testing whether these early warning signals can be detected in highly complex real systems is a key challenge, since much work is either theoretical or only tested with simple models. This is particularly problematic in palaeoclimate and palaeoenvironmental records with low resolution, non-equidistant data, which can limit accurate analysis. Here, a range of different datasets are examined to explore generic rules that can be used to detect such dramatic events. A number of key criteria are identified to be necessary for the reliable identification of early warning signals in natural archives, most crucially, the need for a low-noise record of sufficient data length, resolution and accuracy. A deeper understanding of the underlying system dynamics is required to inform the development of more robust system-specific indicators, or to indicate the temporal resolution required, given a known forcing. This review demonstrates that time series precursors from natural archives provide a powerful means of forewarning tipping points within the Earth System.

  5. Implementation of a Transfer Intervention Procedure (TIP) to improve handovers from hospital to home: interrupted time series analysis.

    PubMed

    van Seben, Rosanne; Geerlings, Suzanne E; Verhaegh, Kim J M; Hilders, Carina G J M; Buurman, Bianca M

    2016-09-07

    Accurate and timely patient handovers from hospital to other health care settings are essential in order to provide high quality of care and to ensure patient safety. We aim to investigate the effect of a comprehensive discharge bundle, the Transfer Intervention Procedure (TIP), on the time between discharge and the time when the medical, medication and nursing handovers are sent to the next health care provider. Our goal is to reduce this time to 24 h after hospital discharge. Secondary outcomes are length of hospital stay and unplanned readmission within 30 days rates. The current study is set to implement the TIP, a structured discharge process for all patients admitted to the hospital, with the purpose to provide a safe, reliable and accurate discharge process. Eight hospitals in the Netherlands will implement the TIP on one internal medicine and one surgical ward. An interrupted time series (ITS) analysis, with pre-defined pre and post intervention periods, will be conducted. Patients over the age of 18 admitted for more than 48 h to the participating wards are eligible for inclusion. At least 1000 patients will be included in both the pre-implementation and post-implementation group. The primary outcome is the number of medical, medication and nursing handovers being sent within 24 h after discharge. Secondary outcomes are length of hospital stay and unplanned readmission within 30 days. With regard to potential confounders, data will be collected on patient's characteristics and information regarding the hospitalization. We will use segmented regression methods for analyzing the data, which allows assessing how much TIP changed the outcomes of interest immediately and over time. This study protocol describes the implementation of TIP, which provides the foundation for a safe, reliable and accurate discharge process. If effective, nationwide implementation of the discharge bundle may result from this study protocol. Dutch Trial Registry: NTR5951.

  6. SepticSmart Homeowners

    EPA Pesticide Factsheets

    EPA’s SepticSmart initiative is a nation-wide public education effort with resources for homeowners with septic systems, local organizations and government leaders to learn how septic systems work and simple, everyday tips on how to properly maintain them.

  7. Twelve tips on teaching and learning humanism in medical education.

    PubMed

    Cohen, Libby Gordon; Sherif, Youmna Ashraf

    2014-08-01

    The teaching of humanistic values is recognized as an essential component of medical education and continuing professional development of physicians. The application of humanistic values in medical care can benefit medical students, clinicians and patients. This article presents 12 tips on fostering humanistic values in medical education. The authors reviewed the literature and present 12 practical tips that are relevant to contemporary practices. The tips can be used in teaching and sustaining humanistic values in medical education. Humanistic values can be incorporated in formal preclinical environments, the transition into clinical settings, medical curricula and clinical clerkships. Additionally, steps can be taken so that medical educators and institutions promote and sustain humanistic values.

  8. Outcomes of Locoregional Tumor Therapy for Patients with Hepatocellular Carcinoma and Transjugular Intrahepatic Portosystemic Shunts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Padia, Siddharth A., E-mail: spadia@uw.edu; Chewning, Rush H., E-mail: rchewnin@uw.edu; Kogut, Matthew J., E-mail: kogutm@uw.edu

    PurposeLocoregional therapy for hepatocellular carcinoma (HCC) can be challenging in patients with a transjugular intrahepatic portosystemic shunt (TIPS). This study compares safety and imaging response of ablation, chemoembolization, radioembolization, and supportive care in patients with both TIPS and HCC.MethodsThis retrospective study included 48 patients who had both a TIPS and a diagnosis of HCC. Twenty-nine of 48 (60 %) underwent treatment for HCC, and 19/48 (40 %) received best supportive care (i.e., symptomatic management only). While etiology of cirrhosis and indication for TIPS were similar between the two groups, treated patients had better baseline liver function (34 vs. 67 % Child-Pugh class C).more » Tumor characteristics were similar between the two groups. A total of 39 ablations, 17 chemoembolizations, and 10 yttrium-90 radioembolizations were performed on 29 patients.ResultsAblation procedures resulted in low rates of hepatotoxicity and clinical toxicity. Post-embolization/ablation syndrome occurred more frequently in patients undergoing chemoembolization than ablation (47 vs. 15 %). Significant hepatic dysfunction occurred more frequently in the chemoembolization group than the ablation group. Follow-up imaging response showed objective response in 100 % of ablation procedures, 67 % of radioembolization procedures, and 50 % of chemoembolization procedures (p = 0.001). When censored for OLT, patients undergoing treatment survived longer than patients receiving supportive care (2273 v. 439 days, p = 0.001).ConclusionsAblation appears to be safe and efficacious for HCC in patients with TIPS. Catheter-based approaches are associated with potential increased toxicity in this patient population. Chemoembolization appears to be associated with increased toxicity compared to radioembolization.« less

  9. Chaos in Atomic Force Microscopy

    NASA Astrophysics Data System (ADS)

    Hu, Shuiqing; Raman, Arvind

    2006-01-01

    Chaotic oscillations of microcantilever tips in dynamic atomic force microscopy (AFM) are reported and characterized. Systematic experiments performed using a variety of microcantilevers under a wide range of operating conditions indicate that softer AFM microcantilevers bifurcate from periodic to chaotic oscillations near the transition from the noncontact to the tapping regimes. Careful Lyapunov exponent and noise titration calculations of the tip oscillation data confirm their chaotic nature. AFM images taken by scanning the chaotically oscillating tips over the sample show small, but significant metrology errors at the nanoscale due to this “deterministic” uncertainty.

  10. Centering Pregnancy: practical tips for your practice.

    PubMed

    DeCesare, Julie Z; Jackson, Jessica R

    2015-03-01

    With increased access to care, current health delivery systems will need expansion to meet higher demands and needs. To define Centering Pregnancy and practical tips for implementation into both private and academic practices. Evidence was gathered through literature reviews. It was found that Centering Pregnancy offers a patient-centered, evidence-based approach to helping with access issues, as well as improving outcomes. This article describes the benefits of Centering Pregnancy to the practice, the provider, and the patient. Practical implementation tips will be offered, with suggestions for negating common implementation barriers.

  11. Mentoring and Coaching Tips: How Educators Can Help Each Other

    ERIC Educational Resources Information Center

    Waterman, Sheryn Spencer

    2013-01-01

    This book is for educators at all levels and is packed with creative, use-now tips and activities to support new and struggling teachers. Combining real-life scenarios with current research, the author demonstrates how educators can get the most out of available resources, promote a school culture devoted to helping and caring, and meet common…

  12. Remote Navigation for Complex Arrhythmia

    PubMed Central

    Suman-Horduna, Irina; Babu-Narayan, Sonya V; Ernst, Sabine

    2013-01-01

    Magnetic navigation has been established as an alternative to conventional, manual catheter navigation for invasive electrophysiology interventions about a decade ago. Besides the obvious advantage of radiation protection for the operator who is positioned remotely from the patient, there are additional benefits of steering the tip of a very floppy catheter. This manuscript reviews the published evidence from simple arrhythmias in patients with normal cardiac anatomy to the most complex congenital heart disease. This progress was made possible by the introduction of improved catheters and most importantly irrigated-tip electrodes. PMID:26835041

  13. Self-navigation of a scanning tunneling microscope tip toward a micron-sized graphene sample.

    PubMed

    Li, Guohong; Luican, Adina; Andrei, Eva Y

    2011-07-01

    We demonstrate a simple capacitance-based method to quickly and efficiently locate micron-sized conductive samples, such as graphene flakes, on insulating substrates in a scanning tunneling microscope (STM). By using edge recognition, the method is designed to locate and to identify small features when the STM tip is far above the surface, allowing for crash-free search and navigation. The method can be implemented in any STM environment, even at low temperatures and in strong magnetic field, with minimal or no hardware modifications.

  14. Take Care of Your Teeth and Gums

    MedlinePlus

    ... This Topic En español Take Care of Your Teeth and Gums Browse Sections The Basics Overview Take ... Brushing Tips 3 of 5 sections Take Action: Dental Checkups Get regular checkups at the dentist. Visit ...

  15. Newborn Care: 10 Tips for Stressed-Out Parents

    MedlinePlus

    ... of Pediatrics Textbook of Pediatric Care. Elk Grove Village, Ill.: American Academy of Pediatrics; 2009:840. Jana ... From Birth to Reality. 3rd ed. Elk Grove Village, Ill.: American Academy of Pediatrics; 2015. Sept. 29, ...

  16. Note: High temperature pulsed solenoid valve.

    PubMed

    Shen, Wei; Sulkes, Mark

    2010-01-01

    We have developed a high temperature pulsed solenoid valve with reliable long term operation to at least 400 degrees C. As in earlier published designs, a needle extension sealing a heated orifice is lifted via solenoid actuation; the solenoid is thermally isolated from the heated orifice region. In this new implementation, superior sealing and reliability were attained by choosing a solenoid that produces considerably larger lifting forces on the magnetically actuated plunger. It is this property that facilitates easily attainable sealing and reliability, albeit with some tradeoff in attainable gas pulse durations. The cost of the solenoid valve employed is quite low and the necessary machining quite simple. Our ultimate level of sealing was attained by making a simple modification to the polished seal at the needle tip. The same sealing tip modification could easily be applied to one of the earlier high T valve designs, which could improve the attainability and tightness of sealing for these implementations.

  17. Recommendations for Achieving Accurate Numerical Simulation of Tip Clearance Flows in Transonic Compressor Rotors

    NASA Technical Reports Server (NTRS)

    VanZante, Dale E.; Strazisar, Anthony J.; Wood, Jerry R,; Hathaway, Michael D.; Okiishi, Theodore H.

    2000-01-01

    The tip clearance flows of transonic compressor rotors are important because they have a significant impact on rotor and stage performance. While numerical simulations of these flows are quite sophisticated. they are seldom verified through rigorous comparisons of numerical and measured data because these kinds of measurements are rare in the detail necessary to be useful in high-speed machines. In this paper we compare measured tip clearance flow details (e.g. trajectory and radial extent) with corresponding data obtained from a numerical simulation. Recommendations for achieving accurate numerical simulation of tip clearance flows are presented based on this comparison. Laser Doppler Velocimeter (LDV) measurements acquired in a transonic compressor rotor, NASA Rotor 35, are used. The tip clearance flow field of this transonic rotor was simulated using a Navier-Stokes turbomachinery solver that incorporates an advanced k-epsilon turbulence model derived for flows that are not in local equilibrium. Comparison between measured and simulated results indicates that simulation accuracy is primarily dependent upon the ability of the numerical code to resolve important details of a wall-bounded shear layer formed by the relative motion between the over-tip leakage flow and the shroud wall. A simple method is presented for determining the strength of this shear layer.

  18. PhenoTips: patient phenotyping software for clinical and research use.

    PubMed

    Girdea, Marta; Dumitriu, Sergiu; Fiume, Marc; Bowdin, Sarah; Boycott, Kym M; Chénier, Sébastien; Chitayat, David; Faghfoury, Hanna; Meyn, M Stephen; Ray, Peter N; So, Joyce; Stavropoulos, Dimitri J; Brudno, Michael

    2013-08-01

    We have developed PhenoTips: open source software for collecting and analyzing phenotypic information for patients with genetic disorders. Our software combines an easy-to-use interface, compatible with any device that runs a Web browser, with a standardized database back end. The PhenoTips' user interface closely mirrors clinician workflows so as to facilitate the recording of observations made during the patient encounter. Collected data include demographics, medical history, family history, physical and laboratory measurements, physical findings, and additional notes. Phenotypic information is represented using the Human Phenotype Ontology; however, the complexity of the ontology is hidden behind a user interface, which combines simple selection of common phenotypes with error-tolerant, predictive search of the entire ontology. PhenoTips supports accurate diagnosis by analyzing the entered data, then suggesting additional clinical investigations and providing Online Mendelian Inheritance in Man (OMIM) links to likely disorders. By collecting, classifying, and analyzing phenotypic information during the patient encounter, PhenoTips allows for streamlining of clinic workflow, efficient data entry, improved diagnosis, standardization of collected patient phenotypes, and sharing of anonymized patient phenotype data for the study of rare disorders. Our source code and a demo version of PhenoTips are available at http://phenotips.org. © 2013 WILEY PERIODICALS, INC.

  19. Trans-jugular intrahepatic porto-systemic shunt placement for refractory ascites: a ‘real-world’ UK health economic evaluation

    PubMed Central

    Parker, Matthew J; Guha, Neil; Stedman, Brian; Hacking, Nigel; Wright, Mark

    2013-01-01

    Objective To assess the benefit of trans-jugular intrahepatic porto-systemic shunt (TIPS) placement for refractory ascites. Design A retrospective observational study of all patients undergoing TIPS for refractory ascites in our hospital between 2003 and 2012. Setting Secondary care. Patients Cirrhotic patients with refractory ascites. Main outcome measures We examined direct real-world (National Health Service) health related costs in the year before and after the TIPS procedure took place. Data were collected relating to the need for reintervention and hepatic encephalopathy. Results Data were available for 24 patients who underwent TIPS for refractory ascites (86% of eligible patients). TIPS was technically successful in all cases. Mean number of bed days in the year prior to TIPS was 30.3 and 14.3 in the year following (p=0.005). No patient had ascites at the end of the year after the TIPS with less requirement for paracentesis over the course of the year (p<0.001). Mean reduction in cost was £2759 per patient. TIPS was especially cost-effective in patients requiring between 6 and 12 drains per year with a mean saving of £9204 per patient. Conclusions TIPS is both a clinically effective and economically advantageous therapeutic option for selected patients with refractory ascites. PMID:28839725

  20. Trans-jugular intrahepatic porto-systemic shunt placement for refractory ascites: a 'real-world' UK health economic evaluation.

    PubMed

    Parker, Matthew J; Guha, Neil; Stedman, Brian; Hacking, Nigel; Wright, Mark

    2013-07-01

    To assess the benefit of trans-jugular intrahepatic porto-systemic shunt (TIPS) placement for refractory ascites. A retrospective observational study of all patients undergoing TIPS for refractory ascites in our hospital between 2003 and 2012. Secondary care. Cirrhotic patients with refractory ascites. We examined direct real-world (National Health Service) health related costs in the year before and after the TIPS procedure took place. Data were collected relating to the need for reintervention and hepatic encephalopathy. Data were available for 24 patients who underwent TIPS for refractory ascites (86% of eligible patients). TIPS was technically successful in all cases. Mean number of bed days in the year prior to TIPS was 30.3 and 14.3 in the year following (p=0.005). No patient had ascites at the end of the year after the TIPS with less requirement for paracentesis over the course of the year (p<0.001). Mean reduction in cost was £2759 per patient. TIPS was especially cost-effective in patients requiring between 6 and 12 drains per year with a mean saving of £9204 per patient. TIPS is both a clinically effective and economically advantageous therapeutic option for selected patients with refractory ascites.

  1. Experimental framework to study tip vortex interactions in multirotor wakes

    NASA Astrophysics Data System (ADS)

    Yao, Rongnan; Araya, Daniel

    2017-11-01

    We present an experimental study to compare the dynamic characteristics of tip vortices shed from a propeller in a crossflow to similar characteristics of an isolated vortex column generated in a closed system. Our aim is to evaluate the feasibility of using this simple isolated system to study the more complicated three-dimensional vortex interactions inherent to multirotor wakes, where the local unsteadiness generated by one rotor can strongly impact the performance of nearby rotors. Time-resolved particle image velocimetry is used to measure the velocity field of the propeller wake flow in a wind tunnel and the vortex column in a water tank. Specific attention is placed on analyzing the observed vortex core precession in the isolated system and comparing this to characteristic tip-vortex wandering phenomenon.

  2. Electron-bombarded 〈110〉-oriented tungsten tips for stable tunneling electron emission

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamada, T. K.; Abe, T.; Nazriq, N. M. K.

    A clean tungsten (W) tip apex with a robust atomic plane is required for producing a stable tunneling electron emission under strong electric fields. Because a tip apex fabricated from a wire by aqueous chemical etching is covered by impurity layers, heating treatment in ultra-high vacuum is experimentally known to be necessary. However, strong heating frequently melts the tip apex and causes unstable electron emissions. We investigated quantitatively the tip apex and found a useful method to prepare a tip with stable tunneling electron emissions by controlling electron-bombardment heating power. Careful characterizations of the tip structures were performed with combinationsmore » of using field emission I–V curves, scanning electron microscopy, X-ray diffraction (transmitted Debye-Scherrer and Laue) with micro-parabola capillary, field ion microscopy, and field emission microscopy. Tips were chemically etched from (1) polycrystalline W wires (grain size ∼1000 nm) and (2) long-time heated W wires (grain size larger than 1 mm). Heating by 10-40 W (10 s) was found to be good enough to remove oxide layers and produced stable electron emission; however, around 60 W (10 s) heating was threshold power to increase the tip radius, typically +10 ± 5 nm (onset of melting). Further, the grain size of ∼1000 nm was necessary to obtain a conical shape tip apex.« less

  3. Facilitated giga-seal formation with a just originated glass surface.

    PubMed

    Böhle, T; Benndorf, K

    1994-07-01

    A simple technique of tip preparation in patch pipettes is described, which facilitates giga-seal formation. The pipettes were fabricated from thick-walled borosilicate glass tubing (external diameter 2.0 mm, internal diameter 0.5 mm) and the tips could be repeatedly broken in the bath. The pipette resistance correspondingly fell in steps of 3-20 M omega from about 80 M omega to about 2 M omega (double concentrated Tyrode). Scanning electron microscopy showed that the tip obtained after breaking was fairly plain. These broken tips were especially appropriate for patch-clamping. In cardiac myocytes in 11 out of 26 patches with Na+ channel activity, giga-seals developed spontaneously, i.e. without suction. In these patches the amplitude of the mean current with depolarizing pulses to -40 mV was significantly higher in comparison with patches formed under negative pressure. It is concluded that spontaneously sealed patches are most likely of planar configuration and the Na+ channel activity exceeds that in suction-induced patches.

  4. 10 Tips for Traveling with Your Loved One

    MedlinePlus

    ... Care Obesity at Midlife May Speed Alzheimer’s Onset Hello from my mom Easing the Behavior Problems of ... Managers Continuing Care FOR MORE ARTICLES CLICK HERE Hello from my mom Common Estate Planning Errors Alzheimer’s ...

  5. Maternity Leave: Tips for Returning to Work

    MedlinePlus

    ... set yourself up for a successful return to work: Find dependable child care. Consider local child care providers and facilities or make other arrangements. Look for a safe, stimulating environment and qualified caregivers. Ask your baby's doctor, friends, ...

  6. The Allium Test--A Simple, Eukaryote Genotoxicity Assay.

    ERIC Educational Resources Information Center

    Babich, H.; Segall, M. A.; Fox, K. D.

    1997-01-01

    Explains the allium test in which roots are excised from onion bulblets grown in aqueous solutions of a test agent. Root tips are then isolated and stained with aceto-orcein, and chromosomal aberrations are microscopically observed. (Author/AIM)

  7. 21 CFR 882.4310 - Powered simple cranial drills, burrs, trephines, and their accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... drilling instruments used on a patient's skull. The instruments are used with a power source but do not have a clutch mechanism to disengage the tip after penetrating the skull. (b) Classification. Class II...

  8. What's Inside the Shell?

    ERIC Educational Resources Information Center

    Hunt, John D.

    1983-01-01

    Marine hermit crabs are a simple and exciting way to introduce landlocked students to the ocean. Tips for keeping the crabs in the classroom, crab anatomy/behavior, and student activities (including a challenge to students to race their crabs) are discussed. (Author/JN)

  9. Tip localization of an atomic force microscope in transmission microscopy with nanoscale precision

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baumann, Fabian; Pippig, Diana A., E-mail: diana.pippig@physik.uni-muenchen.de; Gaub, Hermann E.

    Since the atomic force microscope (AFM) has evolved into a general purpose platform for mechanical experiments at the nanoscale, the need for a simple and generally applicable localization of the AFM cantilever in the reference frame of an optical microscope has grown. Molecular manipulations like in single molecule cut and paste or force spectroscopy as well as tip mediated nanolithography are prominent examples for the broad variety of applications implemented to date. In contrast to the different kinds of superresolution microscopy where fluorescence is used to localize the emitter, we, here, employ the absorbance of the tip to localize itsmore » position in transmission microscopy. We show that in a low aperture illumination, the tip causes a significant reduction of the intensity in the image plane of the microscope objective when it is closer than a few hundred nm. By independently varying the z-position of the sample slide, we could verify that this diffraction limited image of the tip is not caused by a near field effect but is rather caused by the absorbance of the transmitted light in the low apex needle-like tip. We localized the centroid position of this tip image with a precision of better than 6 nm and used it in a feedback loop to position the tip into nano-apertures of 110 nm radius. Single-molecule force spectroscopy traces on the unfolding of individual green fluorescent proteins within the nano-apertures showed that their center positions were repeatedly approached with very high fidelity leaving the specific handle chemistry on the tip’s surface unimpaired.« less

  10. Optical fiber tips for biological applications: From light confinement, biosensing to bioparticles manipulation.

    PubMed

    Paiva, Joana S; Jorge, Pedro A S; Rosa, Carla C; Cunha, João P S

    2018-05-01

    The tip of an optical fiber has been considered an attractive platform in Biology. The simple cleaved end of an optical fiber can be machined, patterned and/or functionalized, acquiring unique properties enabling the exploitation of novel optical phenomena. Prompted by the constant need to measure and manipulate nanoparticles, the invention of the Scanning Near-field Optical Microscopy (SNOM) triggered the optimization and development of novel fiber tip microfabrication methods. In fact, the fiber tip was soon considered a key element in SNOM by confining light to sufficiently small extensions, challenging the diffraction limit. As result and in consequence of the newly proposed "Lab On Tip" concept, several geometries of fiber tips were applied in three main fields: imaging (in Microscopy/Spectroscopy), biosensors and micromanipulation (Optical Fiber Tweezers, OFTs). These are able to exert forces on microparticles, trap and manipulate them for relevant applications, as biomolecules mechanical study or protein aggregates unfolding. This review presents an overview of the main achievements, most impactful studies and limitations of fiber tip-based configurations within the above three fields, along the past 10 years. OFTs could be in future a valuable tool for studying several cellular phenomena such as neurodegeneration caused by abnormal protein fibrils or manipulating organelles within cells. This could contribute to understand the mechanisms of some diseases or biophenomena, as the axonal growth in neurons. To the best of our knowledge, no other review article has so far provided such a broad view. Despite of the limitations, fiber tips have key roles in Biology/Medicine. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. A simple graphene-based pipette tip solid-phase extraction of malondialdehyde from human plasma and its determination by spectrofluorometry.

    PubMed

    Kaykhaii, Massoud; Yahyavi, Hossain; Hashemi, Mohammad; Khoshroo, Mohammad Reza

    2016-07-01

    Determination of malondialdehyde (MDA) in human blood plasma is important because of its role as a biomarker of lipid peroxidation in biological and medical sciences. In this work, a miniaturized graphene-based pipette tip solid-phase extraction technique was developed for very efficient extraction of MDA as its dithiobarbituric acid (TBA) adduct from human plasma. Two milligrams of graphene as sorbent were placed into a pipette tip and MDA-TBA compound was extracted and preconcentrated by it, after 4 repeated aspirating/dispensing cycles, then the column was eluted with 80 μL of dimethyl sulfoxide by 4 repeated aspirating/dispensing cycles and elusion was measured spectrofluorimetrically. Various effective parameters such as type and volume of eluent solvent, temperature, sample volume, number of cycles of extraction and desorption, derivatization reaction time, and pH of the sample solution were investigated and optimized. Under optimum conditions, a linear calibration curve was obtained in the range of 0.5-90 μg L(-1) (r (2) = 0.991) with a detection limit of 0.3 μg L(-1). The relative standard deviations for 8 replicate measurements of 10 and 40 μg L(-1) of MDA were found to be 4.51 and 3.78 % respectively. The developed protocol was successfully applied to the determination of MDA in a human blood plasma sample. Graphical Abstract A simple graphene-based pipette tip solid-phase extraction of malondialdehyde from human plasma and its determination by spectrofluorometry.

  12. Modelling of ‘sub-atomic’ contrast resulting from back-bonding on Si(111)-7×7

    PubMed Central

    Jarvis, Samuel P; Rashid, Mohammad A

    2016-01-01

    Summary It has recently been shown that ‘sub-atomic’ contrast can be observed during NC-AFM imaging of the Si(111)-7×7 substrate with a passivated tip, resulting in triangular shaped atoms [Sweetman et al. Nano Lett. 2014, 14, 2265]. The symmetry of the features, and the well-established nature of the dangling bond structure of the silicon adatom means that in this instance the contrast cannot arise from the orbital structure of the atoms, and it was suggested by simple symmetry arguments that the contrast could only arise from the backbonding symmetry of the surface adatoms. However, no modelling of the system has been performed in order to understand the precise origin of the contrast. In this paper we provide a detailed explanation for ‘sub-atomic’ contrast observed on Si(111)-7×7 using a simple model based on Lennard-Jones potentials, coupled with a flexible tip, as proposed by Hapala et al. [Phys. Rev. B 2014, 90, 085421] in the context of interpreting sub-molecular contrast. Our results show a striking similarity to experimental results, and demonstrate how ‘sub-atomic’ contrast can arise from a flexible tip exploring an asymmetric potential created due to the positioning of the surrounding surface atoms. PMID:27547610

  13. Cracks in Complex Bodies: Covariance of Tip Balances

    NASA Astrophysics Data System (ADS)

    Mariano, Paolo Maria

    2008-04-01

    In complex bodies, actions due to substructural changes alter (in some cases drastically) the force driving the tip of macroscopic cracks in quasi-static and dynamic growth, and must be represented directly. Here it is proven that tip balances of standard and substructural interactions are covariant. In fact, the former balance follows from the Lagrangian density’s requirement of invariance with respect to the action of the group of diffeomorphisms of the ambient space to itself, the latter balance accrues from an analogous invariance with respect to the action of a Lie group over the manifold of substructural shapes. The evolution equation of the crack tip can be obtained by exploiting invariance with respect to relabeling the material elements in the reference place. The analysis is developed by first focusing on general complex bodies that admit metastable states with substructural dissipation of viscous-like type inside each material element. Then we account for gradient dissipative effects that induce nonconservative stresses; the covariance of tip balances in simple bodies follows as a corollary. When body actions and boundary data of Dirichlet type are absent, the standard variational description of quasi-static crack growth is simply extended to the case of complex materials.

  14. The Preignition and Autoignition Oxidation of Alternatives to Petroleum Derived JP-8 and their Surrogate Components in a Pressurized Flow Reactor and Single Cylinder Research Engine

    DTIC Science & Technology

    2009-09-01

    sample probe consisted of TIG welding the 3/8” sample probe shaft to the sample probe tip (Koert, 1990 and Lenhert, 2004b). Silver solder was...was performed in the Drexel University Machine Shop. Conventional TIG welding was sufficient for welding the 3/8” O.D. tube to the sample probe tip...However, to TIG weld the thermocouple and the glass lined tube to the sample probe tip, extreme care had to be taken so as not to damage the

  15. For Caregivers: Coping with Burnout

    MedlinePlus

    ... with ALS and Caregivers ALS Registry Caregivers Assistive Technology for Caregivers Caregiving Tips and Hints The ALS Association Care Connection Coping With Burnout From One Caregiver to Another Respite Care Resources Military Veterans Stories of Courage Newly Diagnosed We’re here for ...

  16. Application of chromatic confocal displacement sensor in measurement of tip clearance

    NASA Astrophysics Data System (ADS)

    Bi, Chao; Li, Di; Fang, Jianguo; Zhang, Bin

    2016-10-01

    In the field of aeronautics, the tip clearance of rotor exerts a crucial influence on the performance of the aero engine. As defined as the radial distance between the top of the blade and the inner wall of the casing, the tip clearance of too large or small size will adversely affect the normal running of the engine. In order to realize accurate measurement of the tip clearance in a simple way, a non-contact measuring method by the chromatic confocal displacement sensor is proposed in the paper. The sensor possesses the advantages such as small volume, good signal-to-noise ratio, high accuracy and response frequency etc., which make it be widely used in engineering and industry. For testing the performance and potential application of the sensor, a simulation testing platform is established. In the platform, a simulation blisk is installed on the air bearing spindle and a chromatic confocal displacement sensor is fixed on the platform to measure the displacement variation of the blade tip, which can be used to characterize the variation of the tip clearance. In the simulation experiments, both of single and continuous measurement of the tip clearance of the 36 blades on the blisk is executed. As the results of experiments show, the chromatic confocal displacement sensor can meet the requirements of measuring task, in which both of high measuring efficiency and accuracy could be achieved. Therefore, the measuring method proposed in the paper can be utilized in the actual assembling sites of the aero engine.

  17. How to Do It. Using the Allium Test to Detect Environmental Pollutants.

    ERIC Educational Resources Information Center

    Kendler, Barry S.; Koritz, Helen G.

    1990-01-01

    Described is a simple test which uses micro- and macro-observations of onion root tips to demonstrate mutagenic and other toxic effects of various contaminants. Discussed are materials, methods, microscopic procedures, and applications of this activity. (CW)

  18. A Simple Demonstration of Allelopathy.

    ERIC Educational Resources Information Center

    Marcus, Bernard A.; Burz, Judy

    1994-01-01

    Uses members of the Cruciferae family such as radishes (Sp. Raphanus), to describe a process termed allelopathy by which a plant uses a chemical compound that escapes into the environment to harm another plant. Tips are provided for easy use in the classroom. (ZWH)

  19. Substance Abuse Treatment for Persons with HIV/AIDS. Treatment Improvement Protocol (TIP) Series 37.

    ERIC Educational Resources Information Center

    CDM Group, Inc.

    The role of substance abuse in the transmission of HIV and AIDS is clear, and the current trend in the pandemic shows that a disproportionate number of minorities in inner cities are affected or are at risk for contracting HIV. The recommendations and guidelines in this TIP support the creation of a comprehensive, integrated system of care for…

  20. Carbon Nanoelectrodes for Single-Cell Probing

    PubMed Central

    Anderson, Sean E.; Bau, Haim H.

    2015-01-01

    Carbon nanoelectrodes with tip diameters ranging from tens to hundreds of nm are fabricated by pyrolitic deposition of carbon films along the entire inner surfaces of pulled-glass pipettes. The pulled end of each glass pipette is then etched to expose a desired length (typically, a few µm) of carbon pipe. The carbon film provides an electrically conductive path from the nanoscopic carbon tip to the distal, macroscopic end of the pipette, bridging between the nanoscale tip and the macroscale handle, without a need for assembly. We used our nanoelectrodes to penetrate into individual cells and cell nuclei and measured the variations in the electrode impedance upon cell and nucleus penetration as well as the electrode impedance as a function of cell penetration depth. Theoretical predictions based on a simple circuit model were in good agreement with experimental data. PMID:25876625

  1. Nanomechanical dissipation at a tip-induced Kondo onset

    NASA Astrophysics Data System (ADS)

    Baruselli, Pier Paolo; Fabrizio, Michele; Tosatti, Erio

    2017-08-01

    The onset or demise of Kondo effect in a magnetic impurity on a metal surface can be triggered, as sometimes observed, by the simple mechanical nudging of a tip. Such a mechanically driven quantum phase transition must reflect in a corresponding mechanical dissipation peak; yet, this kind of signature has not been focused upon so far. Aiming at the simplest theoretical modeling, we treat the impurity as an Anderson impurity model, the tip action as a hybridization switching, and solve the problem by numerical renormalization group. Studying this model as function of temperature and magnetic field we are able to isolate the Kondo contribution to dissipation. While that is, reasonably, of the order of the Kondo energy, its temperature evolution shows a surprisingly large tail even above the Kondo temperature. The detectability of Kondo mechanical dissipation in atomic force microscopy is also discussed.

  2. [Studies on macroscopic and microscopic identification of Cordyceps sinensis and its counterfeits].

    PubMed

    Chan, Siutsau; Liu, Baoling; Zhao, Zhongzhen; Lam, Markin; Law, Kwokwai; Chen, Hubiao

    2011-05-01

    To provide a rapid, simple, accurate and reproducible identification method from which Cordyceps sinensis can be distinguished from other species. To observe the larva and stroma of Cordyceps family with macroscopic identification method, and with powder microscopic identification method. For macroscopic, only stroma of C. sinensis is mostly non-inflated, and un-obtuse at the tip, the caterpillar annulations of C. sinensis and the C. gracilis is distinct, about 20-30, and feet of above two are 8 pairs, 4 of 8 pairs are relatively distinct. The above appearance shows its unique characteristic. For microscopic identification, only C. sinensis exists microtrichia, the tip is pointed. The arranging order of stubby setae is irregular, the tip is blunt while the basal is gradually broader; the top of some setae bends slightly like a hook.

  3. Simple refractometer based on in-line fiber interferometers

    NASA Astrophysics Data System (ADS)

    Esteban, Ó.; Martínez Manuel, R.; Shlyagin, M. G.

    2015-09-01

    A very simple but accurate optical fiber refractometer based on the Fresnel reflection in the fiber tip and two in-line low-reflective mirrors for light intensity referencing is reported. Each mirror was generated by connecting together 2 fiber sections with FC/PC and FC/APC connectors using the standard FC/PC mating sleeve. For the sensor interrogation, a standard DFB diode laser pumped with a sawtooth-wave current was used. A resolution of 6 x 10-4 was experimentally demonstrated using different liquids. A simple sensor construction and the use of low cost components make the reported system interesting for many applications.

  4. Sickle Cell Disease

    MedlinePlus

    ... message, please visit this page: About CDC.gov . Learn Tips for Receiving Better Care in the Emergency Department in Our Fact ... related care in the United States. Read Supplement » VIDEO Sickle Cell Disease: When to Transfuse Learn about indications for blood transfusion in patients with ...

  5. Q-controlled amplitude modulation atomic force microscopy in liquids: An analysis

    NASA Astrophysics Data System (ADS)

    Hölscher, H.; Schwarz, U. D.

    2006-08-01

    An analysis of amplitude modulation atomic force microscopy in liquids is presented with respect to the application of the Q-Control technique. The equation of motion is solved by numerical and analytic methods with and without Q-Control in the presence of a simple model interaction force adequate for many liquid environments. In addition, the authors give an explicit analytical formula for the tip-sample indentation showing that higher Q factors reduce the tip-sample force. It is found that Q-Control suppresses unwanted deformations of the sample surface, leading to the enhanced image quality reported in several experimental studies.

  6. Protocol for Removal of Third Molar Root Tips from the Inferior Alveolar Canal-Crossing the line.

    PubMed

    Punga, Rohit; Keswani, Kiran

    2014-12-01

    The safe removal of third molars involved with the inferior alveolar canal (IAC) has been an area of concern since long. Many times we hesitate for the removal of third molars, fearing injury to the inferior alveolar nerve. The authors here describe a simple technique which can be used to remove third molars showing evidence of proximity to IAC on presurgical radiographic evaluation, as well as those root tips which, during removal, accidentally enter the IAC space. A step-by-step protocol is presented along with necessary precautions during the operative procedure.

  7. Electronic Transport Through Carbon Nanotubes: Effects of Structural Deformation and the Tube Chirality

    NASA Technical Reports Server (NTRS)

    Maiti, Amitesh; Svizhenko, Alexei; Anantram, M. P.; Biegel, Bryan (Technical Monitor)

    2001-01-01

    Atomistic simulations using a combination of classical force field and Density-Functional-Theory (DFT) show that carbon atoms remain essentially sp2 coordinated in either bent tubes or tubes pushed by an atomically sharp AFM tip. Subsequent Green's-function-based transport calculations reveal that for armchair tubes there is no significant drop in conductance, while for zigzag tubes the conductance can drop by several orders of magnitude in AFM-pushed tubes. The effect can be attributed to simple stretching of the tube under tip deformation, which opens up an energy gap at the Fermi surface.

  8. Silver nanowires for highly reproducible cantilever based AFM-TERS microscopy: towards a universal TERS probe.

    PubMed

    Walke, Peter; Fujita, Yasuhiko; Peeters, Wannes; Toyouchi, Shuichi; Frederickx, Wout; De Feyter, Steven; Uji-I, Hiroshi

    2018-04-26

    Tip-enhanced Raman scattering (TERS) microscopy is a unique analytical tool to provide complementary chemical and topographic information of surfaces with nanometric resolution. However, difficulties in reliably producing the necessary metallized scanning probe tips has limited its widespread utilisation, particularly in the case of cantilever-based atomic force microscopy. Attempts to alleviate tip related issues using colloidal or bottom-up engineered tips have so far not reported consistent probes for both Raman and topographic imaging. Here we demonstrate the reproducible fabrication of cantilever-based high-performance TERS probes for both topographic and Raman measurements, based on an approach that utilises noble metal nanowires as the active TERS probe. The tips show 10 times higher TERS contrasts than the most typically used electrochemically-etched tips, and show a reproducibility for TERS greater than 90%, far greater than found with standard methods. We show that TERS can be performed in tapping as well as contact AFM mode, with optical resolutions around or below 15 nm, and with a maximum resolution achieved in tapping-mode of 6 nm. Our work illustrates that superior TERS probes can be produced in a fast and cost-effective manner using simple wet-chemistry methods, leading to reliable and reproducible high-resolution and high-sensitivity TERS, and thus renders the technique applicable for a broad community.

  9. [A simple apparatus for controllable drinking without leaks for laboratory rats].

    PubMed

    Huber, D

    1989-01-01

    A simple device for watering laboratory rats is described. It has been made by using commercially available glass tubing (DURAN 50) with outside diameters of 8 mm, 6 mm, and 3 mm, respectively. The tubes were fused at their tips. The drinking tube is fitted to a rubber stopper at the top of a 250 ml soft polyethylene bottle. By this way water-soluble drugs can be administered to rats with high precision.

  10. Evaluation of carbon nanotube probes in critical dimension atomic force microscopes.

    PubMed

    Choi, Jinho; Park, Byong Chon; Ahn, Sang Jung; Kim, Dal-Hyun; Lyou, Joon; Dixson, Ronald G; Orji, Ndubuisi G; Fu, Joseph; Vorburger, Theodore V

    2016-07-01

    The decreasing size of semiconductor features and the increasing structural complexity of advanced devices have placed continuously greater demands on manufacturing metrology, arising both from the measurement challenges of smaller feature sizes and the growing requirement to characterize structures in more than just a single critical dimension. For scanning electron microscopy, this has resulted in increasing sophistication of imaging models. For critical dimension atomic force microscopes (CD-AFMs), this has resulted in the need for smaller and more complex tips. Carbon nanotube (CNT) tips have thus been the focus of much interest and effort by a number of researchers. However, there have been significant issues surrounding both the manufacture and use of CNT tips. Specifically, the growth or attachment of CNTs to AFM cantilevers has been a challenge to the fabrication of CNT tips, and the flexibility and resultant bending artifacts have presented challenges to using CNT tips. The Korea Research Institute for Standards and Science (KRISS) has invested considerable effort in the controlled fabrication of CNT tips and is collaborating with the National Institute of Standards and Technology on the application of CNT tips for CD-AFM. Progress by KRISS on the precise control of CNT orientation, length, and end modification, using manipulation and focused ion beam processes, has allowed us to implement ball-capped CNT tips and bent CNT tips for CD-AFM. Using two different generations of CD-AFM instruments, we have evaluated these tip types by imaging a line/space grating and a programmed line edge roughness specimen. We concluded that these CNTs are capable of scanning the profiles of these structures, including re-entrant sidewalls, but there remain important challenges to address. These challenges include tighter control of tip geometry and careful optimization of scan parameters and algorithms for using CNT tips.

  11. Scaling up ART adherence clubs in the public sector health system in the Western Cape, South Africa: a study of the institutionalisation of a pilot innovation.

    PubMed

    MacGregor, Hayley; McKenzie, Andrew; Jacobs, Tanya; Ullauri, Angelica

    2018-04-25

    In 2011, a decision was made to scale up a pilot innovation involving 'adherence clubs' as a form of differentiated care for HIV positive people in the public sector antiretroviral therapy programme in the Western Cape Province of South Africa. In 2016 we were involved in the qualitative aspect of an evaluation of the adherence club model, the overall objective of which was to assess the health outcomes for patients accessing clubs through epidemiological analysis, and to conduct a health systems analysis to evaluate how the model of care performed at scale. In this paper we adopt a complex adaptive systems lens to analyse planned organisational change through intervention in a state health system. We explore the challenges associated with taking to scale a pilot that began as a relatively simple innovation by a non-governmental organisation. Our analysis reveals how a programme initially representing a simple, unitary system in terms of management and clinical governance had evolved into a complex, differentiated care system. An innovation that was assessed as an excellent idea and received political backing, worked well whilst supported on a small scale. However, as scaling up progressed, challenges have emerged at the same time as support has waned. We identified a 'tipping point' at which the system was more likely to fail, as vulnerabilities magnified and the capacity for adaptation was exceeded. Yet the study also revealed the impressive capacity that a health system can have for catalysing novel approaches. We argue that innovation in largescale, complex programmes in health systems is a continuous process that requires ongoing support and attention to new innovation as challenges emerge. Rapid scaling up is also likely to require recourse to further resources, and a culture of iterative learning to address emerging challenges and mitigate complex system errors. These are necessary steps to the future success of adherence clubs as a cornerstone of differentiated care. Further research is needed to assess the equity and quality outcomes of a differentiated care model and to ensure the inclusive distribution of the benefits to all categories of people living with HIV.

  12. Nasal tip support: A finite element analysis of the role of the caudal septum during tip depression

    PubMed Central

    Manuel, Cyrus T.; Leary, Ryan; Protsenko, Dmitriy E.; Wong, Brian J.F.

    2014-01-01

    Objective/Hypothesis Although minor and major tip support mechanisms have been described in detail, no quantitative models exist to provide support for the relative contributions of the structural properties of the major alar cartilage, the fibrous attachments to surrounding structures, and the rigid support structures in an objective manner. Study Design The finite element method was used to compute the stress distribution in the nose during simple tip compression, and then identify the specific anatomic structures that resist deformation and thus contribute to “tip support”. Additionally, the impact of caudal septal resection on nasal tip support was examined. Method The computer models consisted of three tissue components with anatomically correct geometries for skin and bone derived from CT data. Septum, upper lateral cartilages, and major alar cartilages were fitted within the model using 3D CAD software. 5mm nasal tip compression was performed on the models with caudal septal resection (3mm and 5 mm) and without resection to simulate palpation, then the resulting spatial distribution of stress and displacement was calculated. Results The von Mises stress in the normal model was primarily concentrated along medial crural angle. As caudal septum length was reduced, stress was redistributed to adjacent soft tissue and bone, resulting in less force acting on the septum. In all models, displacement was greatest near the intermediate crura. Conclusions These models are the first step in the comprehensive mechanical analysis of nasal tip dynamics. Our model supports the concept of the caudal septum and major alar cartilage as providing the majority of critical load-bearing support. Level of Evidence N/A PMID:23878007

  13. Investigation of Unsteady Tip Clearance Flow in a Low-Speed One and Half Stage Axial Compressor with LES And PIV

    NASA Technical Reports Server (NTRS)

    Hah, Chunill; Hathaway, Michael; Katz, Joseph; Tan, David

    2015-01-01

    The primary focus of this paper is to investigate how a rotor's unsteady tip clearance flow structure changes in a low speed one and half stage axial compressor when the rotor tip gap size is increased from 0.5 mm (0.49% of rotor tip blade chord, 2% of blade span) to 2.4 mm (2.34% chord, 4% span) at the design condition are investigated. The changes in unsteady tip clearance flow with the 0.62 % tip gap as the flow rate is reduced to near stall condition are also investigated. A Large Eddy Simulation (LES) is applied to calculate the unsteady flow field at these three flow conditions. Detailed Stereoscopic PIV (SPIV) measurements of the current flow fields were also performed at the Johns Hopkins University in a refractive index-matched test facility which renders the compressor blades and casing optically transparent. With this setup, the unsteady velocity field in the entire flow domain, including the flow inside the tip gap, can be measured. Unsteady tip clearance flow fields from LES are compared with the PIV measurements and both LES and PIV results are used to study changes in tip clearance flow structures. The current study shows that the tip clearance vortex is not a single structure as traditionally perceived. The tip clearance vortex is formed by multiple interlaced vorticities. Therefore, the tip clearance vortex is inherently unsteady. The multiple interlaced vortices never roll up to form a single structure. When phased-averaged, the tip clearance vortex appears as a single structure. When flow rate is reduced with the same tip gap, the tip clearance vortex rolls further upstream and the tip clearance vortex moves further radially inward and away from the suction side of the blade. When the tip gap size is increased at the design flow condition, the overall tip clearance vortex becomes stronger and it stays closer to the blade suction side and the vortex core extends all the way to the exit of the blade passage. Measured and calculated unsteady flow fields inside the tip gap agree fairly well. Instantaneous velocity vectors inside the tip gap from both the PIV and LES do show flow separation and reattachment at the entrance of tip gap as some earlier studies suggested. This area at the entrance of tip gap flow (the pressure side of the blade) is confined very close to the rotor tip section. With a small tip gap (0.5mm), the gap flow looks like a simple two-dimensional channel flow with larger velocity near the casing for both flow rates. A small area with a sharp velocity gradient is observed just above the rotor tip. This strong shear layer is turned radially inward when it collides with the incoming flow and forms the core structure of the tip clearance vortex. When tip gap size is increased to 2.4 mm at the design operation, the radial profile of the tip gap flow changes drastically. With the large tip gap, the gap flow looks like a two-dimensional channel flow only near the casing. Near the rotor top section, a bigger region with very large shear and reversed flow is observed.

  14. The zipper effect: Why different positions along the chromosome suffer different selection pressures

    NASA Astrophysics Data System (ADS)

    de Oliveira, P. M. C.; Moss de Oliveira, S.

    2011-02-01

    Variability within diploid sexual populations comes from two ingredients: mutations and recombination (or crossing-over). On average, the first introduces genetic defects in offspring genomes, while the second is a mechanism which tends to eliminate them, continuously “cleaning” the population genetic pool from harmful mutations along the generations. Here, we propose that loci near the chromosome tips are more effectively cleaned by the recombination mechanism than loci near the chromosome centre. This result implies that clusters of neighbouring, orchestrated-functioning genes, supposed to be more robust against the effects of genetic mutations, are more likely found near the chromosome centres, while isolated genes are more likely found near the tips. We confirm the tip-centre asymmetry through a simple computer agent-based model. In order to test this effect in reality, we also analyse as an example the particular case of HOX genes distributed along the 24 human chromosomes and verify that indeed, most HOX genes belong to such clustered networks located near the chromosome centres. Accordingly, isolated HOX genes are located closer to the tips.

  15. Kinematics, controls, and path planning results for a redundant manipulator

    NASA Technical Reports Server (NTRS)

    Gretz, Bruce; Tilley, Scott W.

    1989-01-01

    The inverse kinematics solution, a modal position control algorithm, and path planning results for a 7 degree of freedom manipulator are presented. The redundant arm consists of two links with shoulder and elbow joints and a spherical wrist. The inverse kinematics problem for tip position is solved and the redundant joint is identified. It is also shown that a locus of tip positions exists in which there are kinematic limitations on self-motion. A computationally simple modal position control algorithm has been developed which guarantees a nearly constant closed-loop dynamic response throughout the workspace. If all closed-loop poles are assigned to the same location, the algorithm can be implemented with very little computation. To further reduce the required computation, the modal gains are updated only at discrete time intervals. Criteria are developed for the frequency of these updates. For commanding manipulator movements, a 5th-order spline which minimizes jerk provides a smooth tip-space path. Schemes for deriving a corresponding joint-space trajectory are discussed. Modifying the trajectory to avoid joint torque saturation when a tip payload is added is also considered. Simulation results are presented.

  16. Atomistic minimal model for estimating profile of electrodeposited nanopatterns

    NASA Astrophysics Data System (ADS)

    Asgharpour Hassankiadeh, Somayeh; Sadeghi, Ali

    2018-06-01

    We develop a computationally efficient and methodologically simple approach to realize molecular dynamics simulations of electrodeposition. Our minimal model takes into account the nontrivial electric field due a sharp electrode tip to perform simulations of the controllable coating of a thin layer on a surface with an atomic precision. On the atomic scale a highly site-selective electrodeposition of ions and charged particles by means of the sharp tip of a scanning probe microscope is possible. A better understanding of the microscopic process, obtained mainly from atomistic simulations, helps us to enhance the quality of this nanopatterning technique and to make it applicable in fabrication of nanowires and nanocontacts. In the limit of screened inter-particle interactions, it is feasible to run very fast simulations of the electrodeposition process within the framework of the proposed model and thus to investigate how the shape of the overlayer depends on the tip-sample geometry and dielectric properties, electrolyte viscosity, etc. Our calculation results reveal that the sharpness of the profile of a nano-scale deposited overlayer is dictated by the normal-to-sample surface component of the electric field underneath the tip.

  17. Improved design for a low temperature scanning tunneling microscope with an in situ tip treatment stage.

    PubMed

    Kim, J-J; Joo, S H; Lee, K S; Yoo, J H; Park, M S; Kwak, J S; Lee, Jinho

    2017-04-01

    The Low Temperature Scanning Tunneling Microscope (LT-STM) is an extremely valuable tool not only in surface science but also in condensed matter physics. For years, numerous new ideas have been adopted to perfect LT-STM performances-Ultra-Low Vibration (ULV) laboratory and the rigid STM head design are among them. Here, we present three improvements for the design of the ULV laboratory and the LT-STM: tip treatment stage, sample cleaving stage, and vibration isolation system. The improved tip treatment stage enables us to perform field emission for the purpose of tip treatment in situ without exchanging samples, while our enhanced sample cleaving stage allows us to cleave samples at low temperature in a vacuum without optical access by a simple pressing motion. Our newly designed vibration isolation system provides efficient space usage while maintaining vibration isolation capability. These improvements enhance the quality of spectroscopic imaging experiments that can last for many days and provide increased data yield, which we expect can be indispensable elements in future LT-STM designs.

  18. Novel germanetellones: XYGe=Te (X, Y = H, F, Cl, Br, I and CN) - structures and energetics. Comparison with the first synthetic successes.

    PubMed

    Jaufeerally, Naziah B; Abdallah, Hassan H; Ramasami, Ponnadurai; Schaefer, Henry F

    2014-03-14

    No stable germanetellone was described until Tbt(Dis)Ge=Te and Tbt(Tip)Ge=Te (Tbt = 2,4,6-tris[bis(trimethylsilyl)methyl]phenyl, Dis = bis(trimethylsilyl)methyl and Tip = 2,4,6-triisopropylphenyl) were reported in 1997. Following these initial experiments, there has arisen considerable interest in Ge[double bond, length as m-dash]Te systems. An obvious question is: why have the simple XYGe=Te (X, Y = H, F, Cl, Br, I and CN) molecules not yet been isolated? In view of the present situation, theoretical information may be of great help for further advances in germanetellone chemistry. A systematic investigation of the XYGe=Te molecules is carried out using the second order Møller-Plesset perturbation theory (MP2) and density functional theory (DFT). The structures and energetics, including ionization potentials (IPad and IPad(ZPVE)), four different forms of neutral-anion separations (EAad, EAad(ZPVE), VEA and VDE) and the singlet-triplet gaps, are reported. The electronegativity (χ) reactivity descriptor for the halogens (F, Cl, Br and I) and the natural charge separations of the Ge=Te moiety are used to assess the interrelated properties of germanetellone and its derivatives. The results are analyzed, discussed and compared with analogous studies of telluroformaldehyde, silanetellone and their derivatives. The thermodynamic viabilities of some of the novel germanetellones have also been evaluated in terms of the bond dissociation enthalpies of Tbt(Dis)Ge=Te and Tbt(Tip)Ge=Te. The simple mono-substituted germanetellones appear to be slightly more thermodynamically favored than Tbt(Dis)Ge=Te and Tbt(Tip)Ge=Te, since the bond dissociation enthalpies of these kinetically stabilized germanetellones are about 28 and 51 kcal mol(-1) lower, respectively.

  19. Trials of Improved Practices (TIPs): A Strategy for Making Long-Lasting Nets Last Longer?

    PubMed Central

    Harvey, Steven A.; Paredes Olórtegui, Maribel; Leontsini, Elli; Ramal Asayag, César; Scott, Kerry; Winch, Peter J.

    2013-01-01

    Long-lasting insecticidal net (LLIN) use is a proven malaria prevention method. Mass distribution has greatly expanded LLIN access in sub-Saharan Africa, but a gap remains between LLIN ownership and use. Furthermore, LLINs wear out more quickly than anticipated. This paper suggests a participatory research strategy—trials of improved practices (TIPs)—that could identify locally appropriate approaches to prolonging net life and increasing effective use. We used TIPs to overcome barriers to optimal net use in the Peruvian Amazon. Working with 15 families in three villages, we tested home treatment of cotton nets, use of an alternative netting fabric, and alternative washing and care instructions. TIPs helped confirm feasibility of these interventions. Although our findings are time- and context-specific, TIPs could help improve consistency and effectiveness of current LLIN use and prolong net lifespan in sub-Saharan Africa and elsewhere. This would help maximize the value of shrinking donor resources for malaria. PMID:23530074

  20. Inflation Fighters.

    ERIC Educational Resources Information Center

    Cohen, Sheldon H., Ed.

    1983-01-01

    Describes a low-cost, high-voltage, two-terminal, constant-current source for student use in electrophoresis experiments (includes circuit diagram) and a simple device for the continuous registering of gas flows. Also lists seven cost-saving tips for chemical reagent, including use decorative stones (purchased from nursery stores) in place of…

  1. How to Have a Healthy Winter | Poster

    Cancer.gov

    Without a doubt, winter is here. Between the icy weather and the recent hustle and bustle of the holidays, everyone is at an increased risk of getting sick. With that in mind, Occupational Health Services has a few simple tips for staying healthy this winter.

  2. A simple technique for transferring excised patches of membrane to different solutions for single channel measurements.

    PubMed

    Quartararo, N; Barry, P H

    1987-12-01

    A technical problem associated with the patch clamp technique has been the changing of solutions bathing the membrane patch. The simple technique described here solves this problem by means of a movable polythene sleeve placed on the shaft of the patch clamp pipette. The sleeve is initially placed so that the tip of the pipette is exposed. A gigaohm seal is formed using standard techniques. The patch is then excised and the sleeve is slipped down a few mm past the end of the tip of the pipette. When the pipette and sleeve is now removed from the solution, a small drop of solution covering the membrane patch is held in place at the end of the sleeve by surface tension. The pipette is then easily transferred to a different solution without passing the membrane patch through the air-water interface. The sleeve is then simply pulled back up the pipette shaft to expose the membrane patch to the new solution.

  3. The effect of the configuration of a single electrode corona discharge on its acoustic characteristics

    NASA Astrophysics Data System (ADS)

    Zhu, Xinlei; Zhang, Liancheng; Huang, Yifan; Wang, Jin; Liu, Zhen; Yan, Keping

    2017-07-01

    A new sparker system based on pulsed spark discharge with a single electrode has already been utilized for oceanic seismic exploration. However, the electro-acoustic energy efficiency of this system is lower than that of arc discharge based systems. A simple electrode structure was investigated in order to improve the electro-acoustic energy efficiency of the spark discharge. Experiments were carried out on an experimental setup with discharge in water driven by a pulsed power source. The voltage-current waveform, acoustic signal and bubble oscillation were recorded when the relative position of the electrode varied. The electro-acoustic energy efficiency was also calculated. The load voltage had a saltation for the invaginated electrode tip, namely an obvious voltage remnant. The more the electrode tip was invaginated, the larger the pressure peaks and first period became. The results show that electrode recessing into the insulating layer is a simple and effective way to improve the electro-acoustic energy efficiency from 2% to about 4%.

  4. Saw-tooth refractive lens for high energy x-ray focusing

    NASA Astrophysics Data System (ADS)

    Antimonov, Mikhail A.; Khounsary, Ali M.

    2014-09-01

    Saw-tooth refractive lens (SRL) provides a comparatively attractive option for X-ray focusing. An SRL assembly consists of two parts, each with an array of triangular structures (prisms), set tilted symmetrically with respect to the incoming beam. Its main advantage is a simple, continuous tunability in energy and focal length. SRLs can be used for both long and short focal length focusing. Long focal distance focusing of an SRL can accurately be predicted using simple analytical relations. However, the focus size at short focal distances focusing may deviate appreciably from the expected demagnified source size when: (1) the length of the SRL is comparable with the focusing distance, (2) the incident beam is not monochromatic, and (3) and the distance between adjacent prism tips, the tip step, is large . The first factor was considered in a previous work while the other two are addressed is this paper. This preliminary work is aimed at a better understanding of the SRL lenses for focusing an undulator beamline at the Advanced Photon Source (APS).

  5. Ectopic Varices in the Gastrointestinal Tract: Short- and Long-Term Outcomes of Percutaneous Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Macedo, Thanila A., E-mail: macedo.thanila@mayo.edu; Andrews, James C.; Kamath, Patrick S.

    2005-04-15

    To evaluate the results of percutaneous management of ectopic varices, a retrospective review was carried out of 14 patients (9 men, 5 women; mean age 58 years) who between 1992 and 2001 underwent interventional radiological techniques for management of bleeding ectopic varices. A history of prior abdominal surgery was present in 12 of 14 patients. The interval between the surgery and percutaneous intervention ranged from 2 to 38 years. Transhepatic portal venography confirmed ectopic varices to be the source of portal hypertension-related gastrointestinal bleeding. Embolization of the ectopic varices was performed by a transhepatic approach with coil embolization of themore » veins draining into the ectopic varices. Transjugular intrahepatic portosystemic shunt (TIPS) was performed in the standard fashion. Eighteen procedures (12 primary coil embolizations, 1 primary TIPS, 2 re-embolizations, 3 secondary TIPS) were performed in 13 patients. One patient was not a candidate for percutaneous treatment. All interventions but one (re-embolization) were technically successful. In 2 of 18 interventions, re-bleeding occurred within 72 hr (both embolization patients). Recurrent bleeding (23 days to 27 months after initial intervention) was identified in 9 procedures (8 coil embolizations, 1 TIPS due to biliary fistula). One patient had TIPS revision because of ultrasound surveillance findings. New encephalopathy developed in 2 of 4 TIPS patients. Percutaneous coil embolization is a simple and safe treatment for bleeding ectopic varices; however, recurrent bleeding is frequent and reintervention often required. TIPS can offer good control of bleeding at the expense of a more complex procedure and associated risk of encephalopathy.« less

  6. The Widom line and dynamical crossover in supercritical water: Popular water models versus experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Corradini, D.; Rovere, M.; Gallo, P., E-mail: gallop@fis.uniroma3.it

    2015-09-21

    In a previous study [Gallo et al., Nat. Commun. 5, 5806 (2014)], we have shown an important connection between thermodynamic and dynamical properties of water in the supercritical region. In particular, by analyzing the experimental viscosity and the diffusion coefficient obtained in simulations performed using the TIP4P/2005 model, we have found that the line of response function maxima in the one phase region, the Widom line, is connected to a crossover from a liquid-like to a gas-like behavior of the transport coefficients. This is in agreement with recent experiments concerning the dynamics of supercritical simple fluids. We here show howmore » different popular water models (TIP4P/2005, TIP4P, SPC/E, TIP5P, and TIP3P) perform in reproducing thermodynamic and dynamic experimental properties in the supercritical region. In particular, the comparison with experiments shows that all the analyzed models are able to qualitatively predict the dynamical crossover from a liquid-like to a gas-like behavior upon crossing the Widom line. Some of the models perform better in reproducing the pressure-temperature slope of the Widom line of supercritical water once a rigid shift of the phase diagram is applied to bring the critical points to coincide with the experimental ones.« less

  7. A Novel Passive Robotic Tool Interface

    NASA Astrophysics Data System (ADS)

    Roberts, Paul

    2013-09-01

    The increased capability of space robotics has seen their uses increase from simple sample gathering and mechanical adjuncts to humans, to sophisticated multi- purpose investigative and maintenance tools that substitute for humans for many external space tasks. As with all space missions, reducing mass and system complexity is critical. A key component of robotic systems mass and complexity is the number of motors and actuators needed. MDA has developed a passive tool interface that, like a household power drill, permits a single tool actuator to be interfaced with many Tool Tips without requiring additional actuators to manage the changing and storage of these tools. MDA's Multifunction Tool interface permits a wide range of Tool Tips to be designed to a single interface that can be pre-qualified to torque and strength limits such that additional Tool Tips can be added to a mission's "tool kit" simply and quickly.

  8. Evaluation of the electrical contact area in contact-mode scanning probe microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Celano, Umberto, E-mail: celano@imec.be, E-mail: u.celano@gmail.com; Chintala, Ravi Chandra; Vandervorst, Wilfried

    The tunneling current through an atomic force microscopy (AFM) tip is used to evaluate the effective electrical contact area, which exists between tip and sample in contact-AFM electrical measurements. A simple procedure for the evaluation of the effective electrical contact area is described using conductive atomic force microscopy (C-AFM) in combination with a thin dielectric. We characterize the electrical contact area for coated metal and doped-diamond tips operated at low force (<200 nN) in contact mode. In both cases, we observe that only a small fraction (<10 nm{sup 2}) of the physical contact (∼100 nm{sup 2}) is effectively contributing to the transportmore » phenomena. Assuming this reduced area is confined to the central area of the physical contact, these results explain the sub-10 nm electrical resolution observed in C-AFM measurements.« less

  9. Decorating fiber nanotip with single perovskite quantum dot and other luminescent nanocrystals synthesized in oil-phase

    NASA Astrophysics Data System (ADS)

    Qian, Yu; Xing, Xing; Xu, Ya; Lu, Zhenda; Zhang, Weihua

    2017-11-01

    We report a simple yet robust method for fabricating single perovskite quantum dot (QD) decorated fiber nanotips. In this method, a single QD is directly picked up and subsequently glued on the apex of a specially fabricated cantilever fiber tip with a high success rate (approx. 70%) without using expensive close-loop feedback systems. Thanks to the flexibility and robustness of the fiber tips, no damage of the tips was observed in the process. Moreover, nanocrystal (NC) dispersing technique was developed to avoid undesired aggregations of QDs, and it guarantees that only one QD is glued each time. Finally, we demonstrate that this technique can also be applied to other oil-phase synthesized NCs, including CdSe QDs and upconversion luminescent NCs. It leads to many important applications on probing the local environment using high performance luminescent nanoprobes.

  10. Development and experimental characterization of a new non contact sensor for blade tip timing

    NASA Astrophysics Data System (ADS)

    Brouckaert, Jean-Francois; Marsili, Roberto; Rossi, Gianluca; Tomassini, Roberto

    2012-06-01

    Performances of blade tip timing measurement systems (BTT), recently used for non contact turbine blade vibration measurements, in terms of uncertainty and resolution are strongly affected by sensor characteristics. The sensors used for BTT generate pulses, to be used also for precise measurements of turbine blades time of arrival. All the literature on this measurement techniques do not address this problem in a clear way, defining the relevant dynamic and static sensor characteristics, fundamental for this application. Till now proximity sensors used are based on optical, capacitive, eddy current and microwave measuring principle. Also pressure sensors has been used. In this paper a new sensing principle is proposed. A proximity sensor based on magnetoresistive sensing element has been assembled end tested. A simple and portable test bench with variable speed, blade tip width, variable clearance was built and used in order to characterize the main sensor performances.

  11. A new way to make diamond tip hosting an atomic sized defect

    NASA Astrophysics Data System (ADS)

    Zhou, Tony; Stohr, Rainer; Dovzhenko, Yuliya; Casola, Francesco; Yacoby, Amir

    The nitrogen-vacancy (NV) center in diamond has been fascinating people with its unique role in quantum information and magnetometry. NV magnetometry was used to investigate many fundamental physics studies and develop a number of industrial applications. One of the powerful aspects of NV magnetometry is the ability to scan in space to perform spatial magnetic field sensing with nano-meter resolution. As a new emerging scanning probe technique, it faces a huge challenge to be widely adopted due to its complexity in fabrication. Here, we report a new simple way of creating diamond tips with tools found in basic clean room facilities and mount the tips onto an experimental apparatus with common lab bench tools. Finally, scanning NV magnetometry was performed to demonstrate its application. This work is supported by the QuASAR project and the Gordon and Betty Moore Foundations EPiQS Initiative through Grant GBMF4531.

  12. Fifty-three years' experience with randomized clinical trials of emergency portacaval shunt for bleeding esophageal varices in Cirrhosis: 1958-2011.

    PubMed

    Orloff, Marshall J

    2014-02-01

    Emergency treatment of bleeding esophageal varices (BEV) consists mainly of endoscopic and pharmacologic measures, with transjugular intrahepatic portal-systemic shunt (TIPS) performed when bleeding is not controlled. Surgical shunt has been relegated to salvage. At the University of California, San Diego, Medical Center, our group has conducted 10 studies of emergency portacaval shunt (EPCS) during 46 years. To describe 2 randomized clinical trials (RCTs) conducted from 1988 to 2011 in unselected consecutive patients who received emergency treatment for BEV. In RCT No. 1, a total of 211 unselected consecutive patients with cirrhosis and acute BEV were randomized to emergency endoscopic sclerotherapy (EEST) (n=106) or EPCS (n=105). In RCT No. 2, a total of 154 unselected consecutive patients with cirrhosis and acute BEV were randomized to TIPS (n=78) or EPCS (n=76). Diagnostic workup was completed within 6 hours of initial contact, and primary treatment was initiated within 8 to 12 hours. Regular follow-up for up to 10 years was accomplished in 100% of the patients. In RCT No. 1, EEST or EPCS; in RCT No. 2, TIPS or EPCS. The 2 groups were compared with regard to survival, control of bleeding, portal-systemic encephalopathy, and direct cost of care. RESULTS Distribution in Child risk classes was almost identical. One-third of patients were in Child class C. Permanent control of bleeding was achieved by EEST in only 20% of the patients and by TIPS in only 22%. In contrast, EPCS permanently controlled bleeding in 97% and 100% of the patients in RCT No. 2 and RCT No. 1, respectively (P<.001). Survival was significantly greater following EPCS than after EEST and TIPS (P<.001). Median survival was more than 10 years following EPCS compared with 1.99 years after TIPS. Occlusion of TIPS was demonstrated in 84% of the patients, 63% of whom underwent TIPS revision, which failed in 80% of the cases. Recurrent portal-systemic encephalopathy developed in 35% of the patients who underwent EEST and 61% of those who received TIPS. In contrast, portal-systemic encephalopathy occurred in 15% of the patients who received EPCS in RCT No. 1 and 21% of those in RCT No. 2. Direct costs of care were 5 to 7 times greater in the EEST ($168100) and TIPS ($264800) groups than in the EPCS ($39000) group (P<.001). Emergency portacaval shunt permanently stopped variceal bleeding, almost never became occluded, accomplished 5 times the long-term survival than EEST or TIPS, and was much less costly than EEST or TIPS. The widespread practice of using EPCS mainly as salvage for failure of endoscopic therapy or TIPS is not supported by the definitive results of these long-term RCTs in unselected patients with cirrhosis. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT00690027 and NCT00734227.

  13. Magnetic energy flow imaging of magnetic recording head with enhanced resolution and sensitivity by A-MFM using high magnetic moment superparamagnetic tip

    NASA Astrophysics Data System (ADS)

    Kumar, Pawan; Cao, Yongze; Suzuki, Yudai; Yoshimura, Satoru; Saito, Hitoshi

    2018-06-01

    In this report, the magnetic energy flow of AC magnetic field is imaged from a perpendicular magnetic recording head by alternating magnetic force microscopy (A-MFM) with high magnetic moment Co0.43(GdOx)0.57 superparamagnetic (SP) tip. The present magnetic energy flow imaging phenomenon is able to detect the flow direction of AC magnetic field energy from the recording head. A simple model for the flow direction of the AC magnetic energy is given and revealed that when the AC magnetic field energy from the surface of main pole increases, the energy from the side cross section decreases due to the periodical change of magnetization direction at the main pole area. The A-MFM magnetic energy imaging performance by 100 nm Co0.43(GdOx)0.57 SP tip is compared with the magnetic field imaging with the 25 nm Co0.80Zr0.05Nb0.15 soft magnetic (SM) tip. The spatial resolution measured by Fourier analysis for Co0.43(GdOx)0.57 SP tip is enhanced dramatically to ˜10 nm with low thermal noise, as compared to ˜13 nm by Co0.80Zr0.05Nb0.15 SM tip as well as the previously reported MFM tip. Moreover, the sensitivity and resolution are investigated for a range of head current to confirm the suitability of the magnetic energy flow imaging by Co0.43(GdOx)0.57 SP tip to low as well as high magnetic field source. Further, the A-MFM measurements are performed with the 100 nm Au coated conducting tip to investigate the possibility of electrostatic contribution in magnetic energy imaging by Co0.43(GdOx)0.57 SP tip and revealed that the present A-MFM measurement is free from any electrostatic artifacts. The present magnetic energy flow imaging phenomena with the high magnetic moment Co0.43(GdOx)0.57 SP tip provides an avenue for the analysis of the magnetic field energy component from the head field profile.

  14. Simple Methods and Rational Design for Enhancing Aptamer Sensitivity and Specificity

    PubMed Central

    Kalra, Priya; Dhiman, Abhijeet; Cho, William C.; Bruno, John G.; Sharma, Tarun K.

    2018-01-01

    Aptamers are structured nucleic acid molecules that can bind to their targets with high affinity and specificity. However, conventional SELEX (Systematic Evolution of Ligands by EXponential enrichment) methods may not necessarily produce aptamers of desired affinity and specificity. Thus, to address these questions, this perspective is intended to suggest some approaches and tips along with novel selection methods to enhance evolution of aptamers. This perspective covers latest novel innovations as well as a broad range of well-established approaches to improve the individual binding parameters (aptamer affinity, avidity, specificity and/or selectivity) of aptamers during and/or post-SELEX. The advantages and limitations of individual aptamer selection methods and post-SELEX optimizations, along with rational approaches to overcome these limitations are elucidated in each case. Further the impact of chosen selection milieus, linker-systems, aptamer cocktails and detection modules utilized in conjunction with target-specific aptamers, on the overall assay performance are discussed in detail, each with its own advantages and limitations. The simple variations suggested are easily available for facile implementation during and/or post-SELEX to develop ultrasensitive and specific assays. Finally, success studies of established aptamer-based assays are discussed, highlighting how they utilized some of the suggested methodologies to develop commercially successful point-of-care diagnostic assays. PMID:29868605

  15. Simple Methods and Rational Design for Enhancing Aptamer Sensitivity and Specificity.

    PubMed

    Kalra, Priya; Dhiman, Abhijeet; Cho, William C; Bruno, John G; Sharma, Tarun K

    2018-01-01

    Aptamers are structured nucleic acid molecules that can bind to their targets with high affinity and specificity. However, conventional SELEX (Systematic Evolution of Ligands by EXponential enrichment) methods may not necessarily produce aptamers of desired affinity and specificity. Thus, to address these questions, this perspective is intended to suggest some approaches and tips along with novel selection methods to enhance evolution of aptamers. This perspective covers latest novel innovations as well as a broad range of well-established approaches to improve the individual binding parameters (aptamer affinity, avidity, specificity and/or selectivity) of aptamers during and/or post-SELEX. The advantages and limitations of individual aptamer selection methods and post-SELEX optimizations, along with rational approaches to overcome these limitations are elucidated in each case. Further the impact of chosen selection milieus, linker-systems, aptamer cocktails and detection modules utilized in conjunction with target-specific aptamers, on the overall assay performance are discussed in detail, each with its own advantages and limitations. The simple variations suggested are easily available for facile implementation during and/or post-SELEX to develop ultrasensitive and specific assays. Finally, success studies of established aptamer-based assays are discussed, highlighting how they utilized some of the suggested methodologies to develop commercially successful point-of-care diagnostic assays.

  16. Refined Dummy Atom Model of Mg(2+) by Simple Parameter Screening Strategy with Revised Experimental Solvation Free Energy.

    PubMed

    Jiang, Yang; Zhang, Haiyang; Feng, Wei; Tan, Tianwei

    2015-12-28

    Metal ions play an important role in the catalysis of metalloenzymes. To investigate metalloenzymes via molecular modeling, a set of accurate force field parameters for metal ions is highly imperative. To extend its application range and improve the performance, the dummy atom model of metal ions was refined through a simple parameter screening strategy using the Mg(2+) ion as an example. Using the AMBER ff03 force field with the TIP3P model, the refined model accurately reproduced the experimental geometric and thermodynamic properties of Mg(2+). Compared with point charge models and previous dummy atom models, the refined dummy atom model yields an enhanced performance for producing reliable ATP/GTP-Mg(2+)-protein conformations in three metalloenzyme systems with single or double metal centers. Similar to other unbounded models, the refined model failed to reproduce the Mg-Mg distance and favored a monodentate binding of carboxylate groups, and these drawbacks needed to be considered with care. The outperformance of the refined model is mainly attributed to the use of a revised (more accurate) experimental solvation free energy and a suitable free energy correction protocol. This work provides a parameter screening strategy that can be readily applied to refine the dummy atom models for metal ions.

  17. Tailored prevention of inpatient falls: development and usability testing of the fall TIPS toolkit.

    PubMed

    Zuyev, Lyubov; Benoit, Angela N; Chang, Frank Y; Dykes, Patricia C

    2011-02-01

    Patient falls and fall-related injuries are serious problems in hospitals. The Fall TIPS application aims to prevent patient falls by translating routine nursing fall risk assessment into a decision support intervention that communicates fall risk status and creates a tailored evidence-based plan of care that is accessible to the care team, patients, and family members. In our design and implementation of the Fall TIPS toolkit, we used the Spiral Software Development Life Cycle model. Three output tools available to be generated from the toolkit are bed poster, plan of care, and patient education handout. A preliminary design of the application was based on initial requirements defined by project leaders and informed by focus groups with end users. Preliminary design partially simulated the paper version of the Morse Fall Scale currently used in hospitals involved in the research study. Strengths and weaknesses of the first prototype were identified by heuristic evaluation. Usability testing was performed at sites where research study is implemented. Suggestions mentioned by end users participating in usability studies were either directly incorporated into the toolkit and output tools, were slightly modified, or will be addressed during training. The next step is implementation of the fall prevention toolkit on the pilot testing units.

  18. Chem 13 News, Number 72, November 1975.

    ERIC Educational Resources Information Center

    Friesen, R. J., Ed.; And Others

    This newsletter contains student experiments and demonstrations suitable for secondary chemistry instruction as well as laboratory safety tips, book reviews and several activities involving the chemistry of winemaking and crime detection. Articles include those on carbon disulfide bonding, the electrolysis of sodium chloride, a simple and accurate…

  19. The Physical Reality of Molecules: They're Dense and They Move Around!

    ERIC Educational Resources Information Center

    Silverstein, Todd P.

    1995-01-01

    Describes a simple and graphic demonstration of molecular motion that utilizes a hot plate, a beaker, tap water, India ink, and a Pasteur pipette with a rubber bulb. Provides tips on guiding students to an understanding of molecular motion using this demonstration. (DDR)

  20. Treatment planning considerations for molar uprighting.

    PubMed

    Kaur, Harsimrat; Pavithra, U S; Shabeer, N N; Reji, Abraham

    2014-01-01

    Molar uprighting cases require individualized treatment planning depending upon condition of ridge, growth pattern of patient, periodontal condition, lower facial height, position of third molar and anchorage. Uprighting of molar was done in two cases--effectively using simple tip back spring in one case and implant in another.

  1. Child Care Recipes: Food for Health and Fun. From USDA's Child and Adult Care Food Program.

    ERIC Educational Resources Information Center

    Food and Nutrition Service (USDA), Washington, DC.

    Intended to help child care providers show young children how to make healthy food choices, this collection contains standardized recipes and kitchen tips to help providers put together great tasting, nutritious meals that will appeal to young children. The recipe instructions are geared for groups of 25 and 50, and have been tested for product…

  2. Fatigue crack growth with single overload - Measurement and modeling

    NASA Technical Reports Server (NTRS)

    Davidson, D. L.; Hudak, S. J., Jr.; Dexter, R. J.

    1987-01-01

    This paper compares experiments with an analytical model of fatigue crack growth under variable amplitude. The stereoimaging technique was used to measure displacements near the tips of fatigue cracks undergoing simple variations in load amplitude-single overloads and overload/underload combinations. Measured displacements were used to compute strains, and stresses were determined from the strains. Local values of crack driving force (Delta-K effective) were determined using both locally measured opening loads and crack tip opening displacements. Experimental results were compared with simulations made for the same load variation conditions using Newman's FAST-2 model. Residual stresses caused by overloads, crack opening loads, and growth retardation periods were compared.

  3. Persistence length measurements from stochastic single-microtubule trajectories.

    PubMed

    van den Heuvel, M G L; Bolhuis, S; Dekker, C

    2007-10-01

    We present a simple method to determine the persistence length of short submicrometer microtubule ends from their stochastic trajectories on kinesin-coated surfaces. The tangent angle of a microtubule trajectory is similar to a random walk, which is solely determined by the stiffness of the leading tip and the velocity of the microtubule. We demonstrate that even a single-microtubule trajectory suffices to obtain a reliable value of the persistence length. We do this by calculating the variance in the tangent trajectory angle of an individual microtubule. By averaging over many individual microtubule trajectories, we find that the persistence length of microtubule tips is 0.24 +/- 0.03 mm.

  4. Determination of stress intensity factors for interface cracks under mixed-mode loading

    NASA Technical Reports Server (NTRS)

    Naik, Rajiv A.; Crews, John H., Jr.

    1992-01-01

    A simple technique was developed using conventional finite element analysis to determine stress intensity factors, K1 and K2, for interface cracks under mixed-mode loading. This technique involves the calculation of crack tip stresses using non-singular finite elements. These stresses are then combined and used in a linear regression procedure to calculate K1 and K2. The technique was demonstrated by calculating three different bimaterial combinations. For the normal loading case, the K's were within 2.6 percent of an exact solution. The normalized K's under shear loading were shown to be related to the normalized K's under normal loading. Based on these relations, a simple equation was derived for calculating K1 and K2 for mixed-mode loading from knowledge of the K's under normal loading. The equation was verified by computing the K's for a mixed-mode case with equal and normal shear loading. The correlation between exact and finite element solutions is within 3.7 percent. This study provides a simple procedure to compute K2/K1 ratio which has been used to characterize the stress state at the crack tip for various combinations of materials and loadings. Tests conducted over a range of K2/K1 ratios could be used to fully characterize interface fracture toughness.

  5. TIPS: Trends for Inclusive Pediatric Services.

    ERIC Educational Resources Information Center

    Connecticut Univ. Health Center, Farmington.

    This guide was developed as part of a project to provide practicing physicians with training to enhance their understanding of and involvement with early intervention and the special education system in Connecticut. The introductory section notes that best practices in both primary medical care and early intervention promote care that is family…

  6. Tips and Tidbits: A Book for Family Day Care Providers.

    ERIC Educational Resources Information Center

    Gonzalez-Mena, Janet

    This book provides practical information and advice designed to help family day care providers solve problems they confront in their daily work with children. The book is organized into 7 sections. Part I, "Effective Ways to Change Unacceptable Behavior," offers recommendations about discipline, alternatives to punishment, modeling, and…

  7. Involving Parents in Their Children's Dental Care.

    ERIC Educational Resources Information Center

    Becker, Donna

    1998-01-01

    Asserts that parent education is vital to good dental hygiene for the whole family. Discusses what Head Start staffers can do to ensure that children's dental needs are being met, particularly in assisting parents with taking responsibility for children's dental hygiene. Covers dental care tips for parents, questions and answers about dental…

  8. Clues about Reading Enrichment (CARE).

    ERIC Educational Resources Information Center

    Daly, Nancy Jo; And Others

    Compiled by members of the Reading Committee of the North Middlesex Regional School District (Massachusetts), this illustrated guide provides tips, suggestions, and activities that parents can follow at home to help their children read. The Clues about Reading Enrichment (CARE) guide notes that regularly reading aloud to and with children is an…

  9. Helping Your Child Learn Self-Care.

    ERIC Educational Resources Information Center

    Murphy, Linda; Corte, Suzanne Della

    1987-01-01

    Practical advice for parents of handicapped children is the focus of this issue on self-care skills including self-feeding, dressing, and personal hygiene. Ten initial tips for teaching skills to children include constant repetition, modeling, and keeping verbal instruction to a minimum. The section on self-feeding addresses the topics of…

  10. Management of Simple Clavicle Fractures by Primary Care Physicians.

    PubMed

    Stepanyan, Hayk; Gendelberg, David; Hennrikus, William

    2017-05-01

    The clavicle is the most commonly fractured bone. Children with simple fractures are often referred to orthopedic surgeons by primary care physician to ensure adequate care. The objective of this study was to show that simple clavicle fractures have excellent outcomes and are within the scope of primary care physician's practice. We performed a retrospective chart review of 16 adolescents with simple clavicle fractures treated with a sling. Primary outcomes were bony union, pain, and function. The patients with simple clavicle fractures had excellent outcomes with no complications or complaints of pain or restriction of their activities of daily living. The outcomes are similar whether treated by an orthopedic surgeon or a primary care physician. The cost to society and the patient is less when the primary care physician manages the fracture. Therefore, primary care physicians should manage simple clavicle fractures.

  11. Fall TIPS: strategies to promote adoption and use of a fall prevention toolkit.

    PubMed

    Dykes, Patricia C; Carroll, Diane L; Hurley, Ann; Gersh-Zaremski, Ronna; Kennedy, Ann; Kurowski, Jan; Tierney, Kim; Benoit, Angela; Chang, Frank; Lipsitz, Stuart; Pang, Justine; Tsurkova, Ruslana; Zuyov, Lyubov; Middleton, Blackford

    2009-11-14

    Patient falls are serious problems in hospitals. Risk factors for falls are well understood and nurses routinely assess for fall risk on all hospitalized patients. However, the link from nursing assessment of fall risk, to identification and communication of tailored interventions to prevent falls is yet to be established. The Fall TIPS (Tailoring Interventions for Patient Safety) Toolkit was developed to leverage existing practices and workflows and to employ information technology to improve fall prevention practices. The purpose of this paper is to describe the Fall TIPS Toolkit and to report on strategies used to drive adoption of the Toolkit in four acute care hospitals. Using the IHI "Framework for Spread" as a conceptual model, the research team describes the "spread" of the Fall TIPS Toolkit as means to integrate effective fall prevention practices into the workflow of interdisciplinary caregivers, patients and family members.

  12. Suspended chains damp wind-induced oscillations of tall flexible structures

    NASA Technical Reports Server (NTRS)

    Reed, W. H., III

    1968-01-01

    Hanging-chain system, which is a form of impact damper, suppresses wind-induced bending oscillations of tall cylindrical antenna masts. A cluster of chains enclosed in a neoprene shroud is suspended inside the tip of the antenna mast, forming a simple method of damping structural vibrations.

  13. Retrograde pyelogram using the flexible cystoscope.

    PubMed

    Reddy, P K; Hulbert, J C

    1986-12-01

    A retrograde pyelogram was performed on 2 men with the flexible choledochonephroscope and a 5F whistle-tip ureteral catheter. The procedure was done on an outpatient basis with topical anesthesia and patient tolerance was good. The technique is simple and is a useful alternative to the classical rigid cystoscopic technique.

  14. Creating a Classroom Kaleidoscope with the World Wide Web.

    ERIC Educational Resources Information Center

    Quinlan, Laurie A.

    1997-01-01

    Discusses the elements of classroom Web presentations: planning; construction, including design tips; classroom use; and assessment. Lists 14 World Wide Web resources for K-12 teachers; Internet search tools (directories, search engines and meta-search engines); a Web glossary; and an example of HTML for a simple Web page. (PEN)

  15. Long-term neurodevelopmental outcomes in children born with gastroschisis: the tiebreaker.

    PubMed

    Gorra, Adam S; Needelman, Howard; Azarow, Kenneth S; Roberts, Holly J; Jackson, Barbara J; Cusick, Robert A

    2012-01-01

    We evaluated 2-year neurodevelopmental outcomes in children with gastroschisis. We reviewed the records of children with gastroschisis treated between August 2001 and July 2008. Children discharged from the neonatal intensive care unit were referred to the state-sponsored Developmental Tracking Infant Progress Statewide (TIPS) program. We reviewed TIPS assessments performed before age 2 years. School districts evaluated children referred by TIPS and determined their eligibility for early intervention services. Poor outcomes were defined as scores of "failure" or "moderate/high risk" on the screening assessment or enrollment in early intervention services by 2 years. Children with gastroschisis were compared with case-matched nonsurgical, nonsyndromic children of similar gestational age and birth weight. One hundred five children were born with gastroschisis, and 46 were followed up with TIPS. There was no statistically significant difference in performance on screening assessments or in the rate of enrollment in early intervention services between the gastroschisis children and controls. Children born with gastroschisis have similar 2-year neurodevelopmental outcomes as nonsurgical, nonsyndromic neonatal intensive care unit children of similar gestational age and birth weight. Both groups of children have a higher rate of enrollment in early intervention than their healthy peers. These data suggest that neurodevelopmental outcomes in gastroschisis children are delayed secondary to prematurity rather than the presence of the surgical disease. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Patient Activated Care for Rural Elderly. A Program Development and Teaching Guide for Planners, Facilitators, and Coordinators.

    ERIC Educational Resources Information Center

    Gaarder, Lorin R.; Cohen, Saul

    This guide is an outline for developing and presenting programs in self health care for senior citizens. The guide is presented in two sections. The first section provides background information about elderly self-care and tips on teaching it and developing a program. Sample letters to prospective enrollees and sample news releases are included.…

  17. Numerical simulation of steady three-dimensional flows in axial turbomachinery bladerows

    NASA Astrophysics Data System (ADS)

    Basson, Anton Herman

    The formulation for and application of a numerical model for low Mach number steady three-dimensional flows in axial turbomachinery blade rows is presented. The formulation considered here includes an efficient grid generation scheme (particularly suited to computational grids for the analysis of turbulent turbomachinery flows) and a semi-implicit, pressure-based computational fluid dynamics scheme that directly includes artificial dissipation, applicable to viscous and inviscid flows. The grid generation technique uses a combination of algebraic and elliptic methods, in conjunction with the Minimal Residual Method, to economically generate smooth structured grids. For typical H-grids in turbomachinery bladerows, when compared to a purely elliptic grid generation scheme, the presented grid generation scheme produces grids with much improved smoothness near the leading and trailing edges, allows the use of small near wall grid spacing required by low Reynolds number turbulence models, and maintains orthogonality of the grid near the solid boundaries even for high flow angle cascades. A specialized embedded H-grid for application particularly to tip clearance flows is presented. This topology smoothly discretizes the domain without modifying the tip shape, while requiring only minor modifications to H-grid flow solvers. Better quantitative modeling of the tip clearance vortex structure than that obtained with a pinched tip approximation is demonstrated. The formulation of artificial dissipation terms for a semi-implicit, pressure-based (SIMPLE type) flow solver, is presented. It is applied to both the Euler and the Navier-Stokes equations, expressed in generalized coordinates using a non-staggered grid. This formulation is compared to some SIMPLE and time marching formulations, revealing the artificial dissipation inherent in some commonly used semi-implicit formulations. The effect of the amount of dissipation on the accuracy of the solution and the convergence rate is quantitatively demonstrated for a number of flow cases. The ability of the formulation to model complex steady turbomachinery flows is demonstrated, e.g. for pressure driven secondary flows, turbine nozzle wakes, turbulent boundary layers. The formulation's modeling of blade surface heat transfer is assessed. The numerical model is used to investigate the structure of phenomena associated with tip clearance flows in a turbine nozzle.

  18. Differences between the family-centered "COPCA" program and traditional infant physical therapy based on neurodevelopmental treatment principles.

    PubMed

    Dirks, Tineke; Blauw-Hospers, Cornill H; Hulshof, Lily J; Hadders-Algra, Mijna

    2011-09-01

    Evidence for effectiveness of pediatric physical therapy in infants at high risk for developmental motor disorders is limited. Therefore, "Coping With and Caring for Infants With Special Needs" (COPCA), a family-centered, early intervention program, was developed. The COPCA program is based on 2 components: (1) family involvement and educational parenting and (2) the neuromotor principles of the neuronal group selection theory. The COPCA coach uses principles of coaching to encourage the family's own capacities for solving problems of daily care and incorporating variation, along with trial and error in daily activities. The purpose of this study was to evaluate whether the content of sessions of the home-based, early intervention COPCA program differs from that of traditional infant physical therapy (TIP) sessions, which in the Netherlands are largely based on neurodevelopmental treatment. The study was conducted at the University Medical Center Groningen in the Netherlands. A quantitative video analysis of therapy sessions was conducted with infants participating in a 2-arm randomized trial. Forty-six infants at high risk for developmental motor disorders were randomly assigned to receive COPCA (n=21) or TIP (n=25) between 3 and 6 months corrected age. Intervention sessions were videotaped at 4 and 6 months corrected age and analyzed with a standardized observation protocol for the classification of physical therapy actions. Outcome parameters were relative amounts of time spent on specific physical therapy actions. The content of COPCA and TIP differed substantially. For instance, in TIP sessions, more time was spent on facilitation techniques, including handling, than in COPCA sessions (29% versus 3%, respectively). During COPCA, more time was spent on family coaching and education than during TIP (16% versus 4%, respectively). The major limitation of the study was its restriction to the Netherlands, implying that findings cannot be generalized automatically to other countries. The COPCA program differs broadly from TIP as applied in the Netherlands. Studies on the effectiveness of this family-centered program are needed.

  19. Structure and properties of small molecule-polymer blend semiconductors for organic thin film transistors.

    PubMed

    Kang, Jihoon; Shin, Nayool; Jang, Do Young; Prabhu, Vivek M; Yoon, Do Y

    2008-09-17

    A comprehensive structural and electrical characterization of solution-processed blend films of 6,13-bis(triisopropylsilylethynyl) pentacene (TIPS-pentacene) semiconductor and poly(alpha-methylstyrene) (PalphaMS) insulator was performed to understand and optimize the blend semiconductor films, which are very attractive as the active layer in solution-processed organic thin-film transistors (OTFTs). Our study, based on careful measurements of specular neutron reflectivity and grazing-incidence X-ray diffraction, showed that the blends with a low molecular-mass PalphaMS exhibited a strong segregation of TIPS-pentacene only at the air interface, but surprisingly the blends with a high molecular-mass PalphaMS showed a strong segregation of TIPS-pentacene at both air and bottom substrate interfaces with high crystallinity and desired orientation. This finding led to the preparation of a TIPS-pentacene/PalphaMS blend active layer with superior performance characteristics (field-effect mobility, on/off ratio, and threshold voltage) over those of neat TIPS-pentacene, as well as the solution-processability of technologically attractive bottom-gate/bottom-contact OTFT devices.

  20. Scabies

    MedlinePlus

    ... too. Wash clothing, sheets, and towels in hot water and dry on a hot setting. Put stuffed animals and other items that ... Sexually Transmitted Diseases (STDs) Tips for Taking Care of Your Skin ...

  1. Influence of Finite Span and Sweep on Active Flow Control Efficacy

    NASA Technical Reports Server (NTRS)

    Greenblatt, David; Washburn, Anthony E.

    2008-01-01

    Active flow control efficacy was investigated by means of leading-edge and flap-shoulder zero mass-flux blowing slots on a semispan wing model that was tested in unswept (standard) and swept configurations. On the standard configuration, stall commenced inboard, but with sweep the wing stalled initially near the tip. On both configurations, leading-edge perturbations increased CL,max and post stall lift, both with and without deflected flaps. Without sweep, the effect of control was approximately uniform across the wing span but remained effective to high angles of attack near the tip; when sweep was introduced a significant effect was noted inboard, but this effect degraded along the span and produced virtually no meaningful lift enhancement near the tip, irrespective of the tip configuration. In the former case, control strengthened the wingtip vortex; in the latter case, a simple semi-empirical model, based on the trajectory or "streamline" of the evolving perturbation, served to explain the observations. In the absence of sweep, control on finite-span flaps did not differ significantly from their nominally twodimensional counterpart. Control from the flap produced expected lift enhancement and CL,max improvements in the absence of sweep, but these improvements degraded with the introduction of sweep.

  2. A scanning probe mounted on a field-effect transistor: Characterization of ion damage in Si.

    PubMed

    Shin, Kumjae; Lee, Hoontaek; Sung, Min; Lee, Sang Hoon; Shin, Hyunjung; Moon, Wonkyu

    2017-10-01

    We have examined the capabilities of a Tip-On-Gate of Field-Effect Transistor (ToGoFET) probe for characterization of FIB-induced damage in Si surface. A ToGoFET probe is the SPM probe which the Field Effect Transistor(FET) is embedded at the end of a cantilever and a Pt tip was mounted at the gate of FET. The ToGoFET probe can detect the surface electrical properties by measuring source-drain current directly modulated by the charge on the tip. In this study, a Si specimen whose surface was processed with Ga+ ion beam was prepared. Irradiation and implantation with Ga+ ions induce highly localized modifications to the contact potential. The FET embedded on ToGoFET probe detected the surface electric field profile generated by schottky contact between the Pt tip and the sample surface. Experimentally, it was shown that significant differences of electric field due to the contact potential barrier in differently processed specimens were observed using ToGOFET probe. This result shows the potential that the local contact potential difference can be measured by simple working principle with high sensitivity. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Protein deposition on field-emitter tips and its removal by UV radiation

    NASA Astrophysics Data System (ADS)

    Panitz, J. A.; Giaever, I.

    1980-07-01

    Protein deposition on field-emitter tips has been examined using Transmission Electron Microscopy to view the protein coated tip profile. A single layer of adsorbed protein is barely if at all detectable, but double and triple layers produced by the immunologic reaction can be directly observed. As a result, the thickness and morphology of antigen-antibody layers has been directly observed for the first time. Tips exposed first to Bovine Serum Albumin (BSA) and then to anti-BSA rabbit serum are covered with a reasonably uniform, double protein layer ≈130 Å thick. This layer can be built-up to a triple layer ≈275 Å thick by additional exposure to anti-rabbit IgG goat serum. Surface tension forces during the drying process which follows protein deposition appear to affect the thickness and morphology of the protein layers. The oxidation and subsequent change in the morphology of a protein layer exposed to ultraviolet radiation has also been observed using TEM. The destruction of a triple protein layer at a rate of ≈0.5 Å/s is observed for tungsten tips exposed to ≈6 W of UV radiation from a high-pressure mercury arc in laboratory ambient. These results are compared to those obtained from a simple, visual test for protein layer adsorption in which submonolayer coverages of protein can be detected with the unaided eye.

  4. 3D PIC-MCC simulations of positive streamers in air gaps

    NASA Astrophysics Data System (ADS)

    Jiang, M.; Li, Y.; Wang, H.; Liu, C.

    2017-10-01

    Simulation of positive streamer evolution is important for understanding the microscopic physical process in discharges. Simulations described in this paper are done using a 3D Particle-In-Cell, Monte-Carlo-Collision code with photoionization. Three phases of a positive streamer evolution, identified as initiation, propagation, and branching are studied during simulations. A homogeneous electric field is applied between parallel-flat electrodes forming a millimeter air gap to make simulations and analysis more simple and general. Free electrons created by the photoionization process determine initiation, propagation, and branching of the streamers. Electron avalanches form a positive streamer tip, when the space charge of ions at the positive tip dominates the local electric field. The propagation of the positive tip toward a cathode is the result of combinations of the positive tip and secondary avalanches ahead of it. A curved feather-like channel is formed without obvious branches when the electric field between electrodes is 50 kV/cm. However, a channel is formed with obvious branches when the electric field increases up to 60 kV/cm. In contrast to the branches around a sharp needle electrode, branches near the flat anode are formed at a certain distance away from it. Simulated parameters of the streamer such as diameter, maximum electric field, propagation velocity, and electron density at the streamer tip are in a good agreement with those published earlier.

  5. Everyday TLC: Teaching, Learning, Caring, 2002.

    ERIC Educational Resources Information Center

    Durkin, Lisa L., Ed.; Miller, Sandy, Ed.

    2002-01-01

    This document is comprised of weekly newsletters for 2002, organized by month, for family child care providers. Each theme-based newsletter contains: (1) creative activities for use with mixed-age groups of 2- to 5-year-olds; (2) ideas on guiding behavior, organization tips, and a Monthly Planning Calendar; (3) special sections for infants and…

  6. Everyday TLC: Teaching, Learning, Caring, 2000.

    ERIC Educational Resources Information Center

    Durkin, Lisa L., Ed.

    2000-01-01

    This document is comprised of weekly newsletters for family child care providers for the year 2000. Each theme-based four-page newsletter contains: (1) creative activities for use with mixed-age groups of 2- to 5-year-olds; (2) ideas on guiding behavior, organization tips, and a Monthly Planning Calendar; (3) special sections for infants and…

  7. Tips on the Care and Adjustment of Vietnamese and Other Asian Children in the United States.

    ERIC Educational Resources Information Center

    Miller, Helen M.

    This handbook provides information related to the physical, emotional, and language problems that may face newly adopted Vietnamese or Korean children and their adoptive parents. Cultural differences among Vietnamese, Korean, and American families in such areas as diet, sleeping customs, clothing, child care, communication, toilet habits, and…

  8. Everyday TLC: Teaching, Learning, Caring, 2003.

    ERIC Educational Resources Information Center

    Durkin, Lisa L., Ed.; Miller, Sandy, Ed.

    2003-01-01

    This document is comprised of weekly newsletters, compiled by month, for family child care providers for the year 2003. Each theme-based four-page newsletter contains: (1) creative activities for use with mixed-age groups of 2- to 5-year-olds; (2) ideas on guiding behavior, organization tips, and Monthly Planning Calendar; (3) special sections for…

  9. College Student Self-Care Diary.

    ERIC Educational Resources Information Center

    Greenberg, Jerrold S.; Dintiman, George B.

    The purpose of this docoment is to help college students maintain health by keeping a weekly diary of health related behaviors including diet, exercise, and stress levels. In addition each weekly entry presents a self-care tip for health improvement. Discussions of the college student and health, health and lifestyle, instructions on use of the…

  10. Your Glucose Meter

    MedlinePlus

    ... Medical Devices Radiation-Emitting Products Vaccines, Blood & Biologics Animal & Veterinary Cosmetics Tobacco ... 164KB) En Español Basic Facts 7 Tips for Testing Your Blood Sugar and Caring for Your Meter ...

  11. Cultivar-Dependent Direct Organogenesis of Date Palm from Shoot Tip Explants.

    PubMed

    Abahmane, Larbi

    2017-01-01

    A number of public and private laboratories are working on date palm micropropagation to meet the increasing worldwide demand for date palm planting material. A standardized direct organogenesis protocol exists for the production of date palm plantlets to maintain the genetic fidelity of regenerated plants. Organogenesis has the advantage of using low concentrations of plant growth regulators and avoiding the callus phase. In addition, direct regeneration of vegetative buds minimizes the risk of somaclonal variation among plant regenerants. However, in vitro multiplication cycles should be limited in duration by frequent renewal of plant material. This chapter describes a simple and routine organogenesis protocol for date palm multiplication using shoot tip explants.

  12. Affordable Acoustic Disdrometer: Design, Calibration, Tests

    NASA Astrophysics Data System (ADS)

    van de Giesen, N.; Degen, C.; Hut, R.

    2009-12-01

    It would be a hydrological understatement to say that measuring rainfall correctly is important. Recent years have seen important lowering of the costs of raingauges capable of measuring rainfall intensities. Such raingauges are typically tipping bucket raingauges, connected to an event logger. Costs for such a raingauge are about 100. Accuracy is not always very high, especially during high intensity storms. The moving parts make them vulnerable to slight disruptions such as insects. We set out to design a raingauge without moving parts and at a better price/quality ratio than existing raingauges. After testing several potential candidates, we settled on a very simple piezo ceramic element, which measures the impact of single drops. Such an element costs around 1. The impact of each drop causes an acoustic signal that is transformed into a voltage. A typical impact gives an upswing of up to 1 V and the ringing lasts about 50 ms. With a surface area of about 20 cm2, there is almost never overlap between the signals of different drops. The basic assumption is that each drop will have reached terminal velocity and that the total energy of the impact can, thereby, be related to drop size. We calibrated this acoustic disdrometer by letting drops of different size fall on the disdrometer. A very encouraging calibration curve was obtained in this way. Further testing consisted of comparisons during rainstorms between the acoustic disdrometer and standard tipping bucket raingauges. During intensive storms, the acoustic disdrometer gave results that were very close to those of a nearby totaling raingauge. The signal of the tipping bucket raingauges was clearly saturated as these were not capable of keeping up with the rain. During low intensity events, tipping bucket raingauges performed better as drops too small to detect by the acoustic disdrometer became a significant part of the total rainfall. In first instance, a simple MP3 player with recording functionality ($50) was used as datalogger and processing was performed with a Matlab script. Presently, processing is done on-board of a simple custom built logger that logs the time and total energy of each drop. Post-processing converts the total energy to drop size and corrects for missing small drops by fitting the pdf’s to known raindrop distributions.

  13. CPTED 101: Crime Prevention through Environmental Design--The Fundamentals for Schools

    ERIC Educational Resources Information Center

    Schneider, Tod

    2010-01-01

    Crime Prevention through Environmental Design (CPTED) 101 applies to both new and existing schools and is built on three simple concepts: natural surveillance, natural access control, and territoriality. If a school's layout seems unsafe, adopting a few CPTED fundamentals may help make it significantly safer. This paper offers some tips for making…

  14. Tell It Again! Easy-to-Tell Stories with Activities for Young Children.

    ERIC Educational Resources Information Center

    Raines, Shirley C.; Isbell, Rebecca

    Listening to stories can expand children's knowledge, provide sheer enjoyment, and help children understand their world and how people relate to each other in it. This book compiles tips and suggestions from expert storytellers and teachers, and shows teachers and parents how to capture children's attention and imagination using simple, creative…

  15. Environmental Education, Drought and the Rural Man: Implications for Policy-Makers and Farmers in Sub-Saharan Africa.

    ERIC Educational Resources Information Center

    Ladele, Ademola A.

    2001-01-01

    Examines issues related to the nexus of some factors affecting the environment, specifically drought. Suggests that because small farmers are usually at the mercy of unpredictable weather, even simple tips on resource management, when properly packaged, could make tremendous change. (Contains 27 references.) (Author/YDS)

  16. Centers Made Simple: A Management and Activity Guide

    ERIC Educational Resources Information Center

    Reynolds, Laureen

    2005-01-01

    Drawing from her own experiences, teacher and author Laureen Reynolds shares management strategies, helpful suggestions, and quick tips to take the mystery out of setting up centers and demonstrates how to make the most of valuable classroom time. The activities outlined in this book are designed to appeal to students of all abilities, and range…

  17. Mammalian Cell Encapsulation in Alginate Beads Using a Simple Stirred Vessel.

    PubMed

    Hoesli, Corinne A; Kiang, Roger L J; Raghuram, Kamini; Pedroza, René G; Markwick, Karen E; Colantuoni, Antonio M R; Piret, James M

    2017-06-29

    Cell encapsulation in alginate beads has been used for immobilized cell culture in vitro as well as for immunoisolation in vivo. Pancreatic islet encapsulation has been studied extensively as a means to increase islet survival in allogeneic or xenogeneic transplants. Alginate encapsulation is commonly achieved by nozzle extrusion and external gelation. Using this method, cell-containing alginate droplets formed at the tip of nozzles fall into a solution containing divalent cations that cause ionotropic alginate gelation as they diffuse into the droplets. The requirement for droplet formation at the nozzle tip limits the volumetric throughput and alginate concentration that can be achieved. This video describes a scalable emulsification method to encapsulate mammalian cells in 0.5% to 10% alginate with 70% to 90% cell survival. By this alternative method, alginate droplets containing cells and calcium carbonate are emulsified in mineral oil, followed by a decrease in pH leading to internal calcium release and ionotropic alginate gelation. The current method allows the production of alginate beads within 20 min of emulsification. The equipment required for the encapsulation step consists in simple stirred vessels available to most laboratories.

  18. Managing Rosacea

    MedlinePlus

    ... System Vascular Changes Demodex & Microbes Bibliography Genetics The Ecology of Your Face It Works for Me: Patient ... Tips Skin Care & Cosmetics Causes of Rosacea The Ecology of Your Face It Works for Me: Patient ...

  19. OVERVIEW, PRACTICAL TIPS AND POTENTIAL PITFALLS OF USING AUTOMATIC EXPOSURE CONTROL IN CT: SIEMENS CARE DOSE 4D.

    PubMed

    Söderberg, Marcus

    2016-06-01

    Today, computed tomography (CT) systems routinely use automatic exposure control (AEC), which modulates the tube current. However, for optimal use, there are several aspects of an AEC system that need to be considered. The purpose of this study was to provide an overview of the Siemens CARE Dose 4D AEC system, discuss practical tips and demonstrate potential pitfalls. Two adult anthropomorphic phantoms were examined using two different Siemens CT systems. When optimising the CT radiation dose and image quality, the projection angle of the localiser, patient centring, protocol selection, scanning direction and the use of protective devices requires special attention. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. The African Origin of Complex Projectile Technology: An Analysis Using Tip Cross-Sectional Area and Perimeter

    PubMed Central

    Sisk, Matthew L.; Shea, John J.

    2011-01-01

    Despite a body of literature focusing on the functionality of modern and stylistically distinct projectile points, comparatively little attention has been paid to quantifying the functionality of the early stages of projectile use. Previous work identified a simple ballistics measure, the Tip Cross-Sectional Area, as a way of determining if a given class of stone points could have served as effective projectile armatures. Here we use this in combination with an alternate measure, the Tip Cross-Sectional Perimeter, a more accurate proxy of the force needed to penetrate a target to a lethal depth. The current study discusses this measure and uses it to analyze a collection of measurements from African Middle Stone Age pointed stone artifacts. Several point types that were rejected in previous studies are statistically indistinguishable from ethnographic projectile points using this new measure. The ramifications of this finding for a Middle Stone Age origin of complex projectile technology is discussed. PMID:21755048

  1. Imaging of viscoelastic soft matter with small indentation using higher eigenmodes in single-eigenmode amplitude-modulation atomic force microscopy.

    PubMed

    Nikfarjam, Miead; López-Guerra, Enrique A; Solares, Santiago D; Eslami, Babak

    2018-01-01

    In this short paper we explore the use of higher eigenmodes in single-eigenmode amplitude-modulation atomic force microscopy (AFM) for the small-indentation imaging of soft viscoelastic materials. In viscoelastic materials, whose response depends on the deformation rate, the tip-sample forces generated as a result of sample deformation increase as the tip velocity increases. Since the eigenfrequencies in a cantilever increase with eigenmode order, and since higher oscillation frequencies lead to higher tip velocities for a given amplitude (in viscoelastic materials), the sample indentation can in some cases be reduced by using higher eigenmodes of the cantilever. This effect competes with the lower sensitivity of higher eigenmodes, due to their larger force constant, which for elastic materials leads to greater indentation for similar amplitudes, compared with lower eigenmodes. We offer a short theoretical discussion of the key underlying concepts, along with numerical simulations and experiments to illustrate a simple recipe for imaging soft viscoelastic matter with reduced indentation.

  2. National Rosacea Society

    MedlinePlus

    ... System Vascular Changes Demodex & Microbes Bibliography Genetics The Ecology of Your Face It Works for Me: Patient ... Care & Cosmetics Makeup Tips Causes of Rosacea The Ecology of Your Face It Works for Me: Patient ...

  3. 3D printed, bio-inspired prototypes and analytical models for structured suture interfaces with geometrically-tuned deformation and failure behavior

    NASA Astrophysics Data System (ADS)

    Lin, Erica; Li, Yaning; Ortiz, Christine; Boyce, Mary C.

    2014-12-01

    Geometrically structured interfaces in nature possess enhanced, and often surprising, mechanical properties, and provide inspiration for materials design. This paper investigates the mechanics of deformation and failure mechanisms of suture interface designs through analytical models and experiments on 3D printed polymer physical prototypes. Suture waveforms with generalized trapezoidal geometries (trapezoidal, rectangular, anti-trapezoidal, and triangular) are studied and characterized by several important geometric parameters: the presence or absence of a bonded tip region, the tip angle, and the geometry. It is shown that a wide range (in some cases as great as an order of magnitude) in stiffness, strength, and toughness is achievable dependent on tip bonding, tip angle, and geometry. Suture interfaces with a bonded tip region exhibit a higher initial stiffness due to the greater load bearing by the skeletal teeth, a double peak in the stress-strain curve corresponding to the failure of the bonded tip and the failure of the slanted interface region or tooth, respectively, and an additional failure and toughening mechanism due to the failure of the bonded tip. Anti-trapezoidal geometries promote the greatest amplification of properties for suture interfaces with a bonded tip due the large tip interface area. The tip angle and geometry govern the stress distributions in the teeth and the ratio of normal to shear stresses in the interfacial layers, which together determine the failure mechanism of the interface and/or the teeth. Rectangular suture interfaces fail by simple shearing of the interfaces. Trapezoidal and triangular suture interfaces fail by a combination of shear and tensile normal stresses in the interface, leading to plastic deformation, cavitation events, and subsequent stretching of interface ligaments with mostly elastic deformation in the teeth. Anti-trapezoidal suture interfaces with small tip angles have high stress concentrations in the teeth and fail catastrophically by tooth failure, whereas larger tip angles exhibit a shear failure of the interfaces. Therefore, larger tip angles and trapezoidal or triangular geometries promote graceful failure, and smaller tip angles and anti-trapezoidal geometries promote more brittle-like failure. This dependence is reminiscent of biological systems, which exhibit a range of failure behaviors with limited materials and varied geometry. Triangular geometries uniquely exhibit uniform stress distributions in its teeth and promote the greatest amplification of mechanical properties. In both the bonded and unbonded cases, the predictions from the presented analytical models and experimental results on 3D printed prototypes show excellent agreement. This validates the analytical models and allows for the models to be used as a tool for the design of new materials and interfaces with tailored mechanical behavior.

  4. Kinematics of fault-related folding derived from a sandbox experiment

    NASA Astrophysics Data System (ADS)

    Bernard, Sylvain; Avouac, Jean-Philippe; Dominguez, StéPhane; Simoes, Martine

    2007-03-01

    We analyze the kinematics of fault tip folding at the front of a fold-and-thrust wedge using a sandbox experiment. The analog model consists of sand layers intercalated with low-friction glass bead layers, deposited in a glass-sided experimental device and with a total thickness h = 4.8 cm. A computerized mobile backstop induces progressive horizontal shortening of the sand layers and therefore thrust fault propagation. Active deformation at the tip of the forward propagating basal décollement is monitored along the cross section with a high-resolution CCD camera, and the displacement field between pairs of images is measured from the optical flow technique. In the early stage, when cumulative shortening is less than about h/10, slip along the décollement tapers gradually to zero and the displacement gradient is absorbed by distributed deformation of the overlying medium. In this stage of detachment tip folding, horizontal displacements decrease linearly with distance toward the foreland. Vertical displacements reflect a nearly symmetrical mode of folding, with displacements varying linearly between relatively well defined axial surfaces. When the cumulative slip on the décollement exceeds about h/10, deformation tends to localize on a few discrete shear bands at the front of the system, until shortening exceeds h/8 and deformation gets fully localized on a single emergent frontal ramp. The fault geometry subsequently evolves to a sigmoid shape and the hanging wall deforms by simple shear as it overthrusts the flat ramp system. As long as strain localization is not fully established, the sand layers experience a combination of thickening and horizontal shortening, which induces gradual limb rotation. The observed kinematics can be reduced to simple analytical expressions that can be used to restore fault tip folds, relate finite deformation to incremental folding, and derive shortening rates from deformed geomorphic markers or growth strata.

  5. History of Bioterrorism: Botulism

    MedlinePlus Videos and Cool Tools

    ... on this page will be unavailable. For more information about this message, please visit this page: About ... Emergency Responders: Tips for taking care of yourself Information on Specific Types of Emergencies Situation Awareness Hurricanes ...

  6. Rotator cuff - self-care

    MedlinePlus

    ... good posture in general to keep your shoulder blade and joint in their right positions. Other tips ... joint Good range of motion of your shoulder blade and upper spine No pain during certain physical ...

  7. Distributed force probe bending model of critical dimension atomic force microscopy bias

    NASA Astrophysics Data System (ADS)

    Ukraintsev, Vladimir A.; Orji, Ndubuisi G.; Vorburger, Theodore V.; Dixson, Ronald G.; Fu, Joseph; Silver, Rick M.

    2013-04-01

    Critical dimension atomic force microscopy (CD-AFM) is a widely used reference metrology technique. To characterize modern semiconductor devices, small and flexible probes, often 15 to 20 nm in diameter, are used. Recent studies have reported uncontrolled and significant probe-to-probe bias variation during linewidth and sidewall angle measurements. To understand the source of these variations, tip-sample interactions between high aspect ratio features and small flexible probes, and their influence on measurement bias, should be carefully studied. Using theoretical and experimental procedures, one-dimensional (1-D) and two-dimensional (2-D) models of cylindrical probe bending relevant to carbon nanotube (CNT) AFM probes were developed and tested. An earlier 1-D bending model was refined, and a new 2-D distributed force (DF) model was developed. Contributions from several factors were considered, including: probe misalignment, CNT tip apex diameter variation, probe bending before snapping, and distributed van der Waals-London force. A method for extracting Hamaker probe-surface interaction energy from experimental probe-bending data was developed. Comparison of the new 2-D model with 1-D single point force (SPF) model revealed a difference of about 28% in probe bending. A simple linear relation between biases predicted by the 1-D SPF and 2-D DF models was found. The results suggest that probe bending can be on the order of several nanometers and can partially explain the observed CD-AFM probe-to-probe variation. New 2-D and three-dimensional CD-AFM data analysis software is needed to take full advantage of the new bias correction modeling capabilities.

  8. Be More Involved in Your Health Care: Tips for Patients

    MedlinePlus

    ... Scientific Peer Review Award Process Post-Award Grant Management AHRQ Grantee Profiles Getting Recognition for Your AHRQ-Funded Study Contracts Project Research Online Database (PROD) Searchable database of AHRQ ...

  9. Care for an Uncircumcised Penis

    MedlinePlus

    ... tip of the penis. This is called foreskin retraction. Most boys will be able to retract their ... how to retract his own foreskin. But foreskin retraction should never be forced. Until the foreskin fully ...

  10. The EChemPen: A Guiding Hand to Learn Electrochemical Surface Modifications

    ERIC Educational Resources Information Center

    Valetaud, Mathieu; Loget, Gabriel; Roche, Je´rome; Hu¨sken, Nina; Fattah, Zahra; Badets, Vasilica; Fontaine, Olivier; Zigah, Dodzi

    2015-01-01

    The Electrochemical Pen (EChemPen) was developed as an attractive tool for learning electrochemistry. The fabrication, principle, and operation of the EChemPen are simple and can be easily performed by students in practical classes. It is based on a regular fountain pen principle, where the electrolytic solution is dispensed at a tip to locally…

  11. Simple Tips for Helping Students Become Safer, Smarter Social Media Users

    ERIC Educational Resources Information Center

    Agosto, Denise E.; Abbas, June

    2016-01-01

    In thinking about teens and online risks, school librarians need to know researchers generally agree that, despite the popular image of pedophiles and criminals lurking online waiting to harm innocent young people, in reality social media use is only about as risky as most everyday social interactions in the offline world (Agosto and Abbas 2013).…

  12. Troubleshooting Microcomputers. A Technical Guide for Polk County Schools.

    ERIC Educational Resources Information Center

    Black, B. R.; And Others

    This guide was started in 1986 as an effort to pull together a collection of several computer guides that had been written over the previous several years to assist schools in making simple computer repairs. The first of six sections contains general tips and hints, including sections on tool requirements, strobe disk speed adjustment, static…

  13. Construction of Ag/AgCl Reference Electrode from Used Felt-Tipped Pen Barrel for Undergraduate Laboratory

    ERIC Educational Resources Information Center

    Inamdar, Shaukatali N.; Bhat, Mohsin A.; Haram, Santosh K.

    2009-01-01

    A reference electrode is one of the prerequisites of electrochemical investigations. Many electrodes are commercially available but are expensive and prone to accidental breakage by students. Here we report a simple, easy-to-fabricate, inexpensive, reliable, unbreakable, and reproducible Ag/AgCl reference electrode. The empty barrel of a…

  14. From Cloud to Mobile: Drawing down Big Info into Little Apps

    ERIC Educational Resources Information Center

    Herther, Nancy K.

    2011-01-01

    With the release of Google's App Inventor for Android, though still officially in beta, the company sought to make app development "simple but powerful" so that teachers could create study tips and quizzes, anyone could create geographic information systems (GIS) to help people find their way to some destination, and people could communicate over…

  15. Thermomechanical coupling and dynamic strain ageing in ductile fracture

    NASA Astrophysics Data System (ADS)

    Delafosse, David

    1995-01-01

    This work is concerned with plastic deformation at the tip of a ductile tearing crack during propagation. Two kinds of effects are investigated: the thermomechanical coupling at the tip of a mobile ductile crack, and the influence of Dynamic Strain Aging (DSA) on ductile fracture. Three alloys are studied: a nickel based superalloy (N18), a soft carbon steel, and an Al-Li light alloy (2091). The experimental study of the thermo mechanical coupling effects by means of infrared thermography stresses the importance of plastic dissipation in the energy balance of ductile fracture. Numerical simulations involving plastic deformation as the only dissipation mechanism account for the main part of the measured heating. The effects of DSA on ductile tearing are investigated in the 2091 Al-Li alloy. Based on the strain rate/temperature dependence predicted by the standard model of DSA, an experimental procedure is set up for this purpose. Three main effects are evidenced. A maximum in tearing resistance is shown to be associated with the minimum of strain rate sensitivity. Through a simple model, this peak in tearing resistance is attributed to an increase in plastic dissipation as the strain rate sensitivity is decreased. Heterogenous plastic deformation is observed in the crack tip plastic zone. Comparison with uniaxial testing allows us to identify the observed strain heterogeneities as Portevin-Le Chatelier instabilities in the crack tip plastic zone. We perform a simplified numerical analysis of the effect of strain localization on crack tip screening. Finally, small crack propagation instabilities appear at temperatures slightly above that of the tearing resistance peak. These are interpreted as resulting from a positive feed-back between the local heating at the tip of a moving crack and the decrease in tearing resistance with increasing temperature.

  16. Tips for Divorcing Parents

    MedlinePlus

    ... More for Teens Teens site Sitio para adolescentes Body Mind Sexual Health Food & Fitness Diseases & Conditions Infections Drugs & ... your kids how to take good care of mind and body during difficult times can help them become more ...

  17. HealthCare.gov

    MedlinePlus

    ... Search 2018 Open Enrollment is over. Still need health insurance? You can enroll in or change plans if ... reminders, useful tips, and other information about your health insurance. Your information contains error(s): Please choose a state. ...

  18. Tips for Good Oral Health during Pregnancy

    MedlinePlus

    ... consumerbrochures. html. Resources Cavity Keep Away (brochure and poster in English and Spanish) produced by the California ... page/ patient_ education_ tools. Pregnancy and Dental Care (poster and wallet card) produced by the New York ...

  19. Self-Help Tips for Vulvar Skin Care

    MedlinePlus

    ... preventive strategy. Clothing and Laundry Wear all-white cotton underwear. Do not wear pantyhose (wear thigh high ... least 8 glasses of water daily. Use 100% cotton menstrual pads and tampons. Sexual intercourse Use a ...

  20. 6 Tips to Avoid Medication Mistakes

    MedlinePlus

    ... marketing the Electronic Medication Management Assistant (EMMA), a programmable device that stores and dispenses prescription medication for ... Of Your Health Care Team (article) Consumer Educational Materials: What You Need to Know to Use Medicine ...

  1. EFM data mapped into 2D images of tip-sample contact potential difference and capacitance second derivative.

    PubMed

    Lilliu, S; Maragliano, C; Hampton, M; Elliott, M; Stefancich, M; Chiesa, M; Dahlem, M S; Macdonald, J E

    2013-11-27

    We report a simple technique for mapping Electrostatic Force Microscopy (EFM) bias sweep data into 2D images. The method allows simultaneous probing, in the same scanning area, of the contact potential difference and the second derivative of the capacitance between tip and sample, along with the height information. The only required equipment consists of a microscope with lift-mode EFM capable of phase shift detection. We designate this approach as Scanning Probe Potential Electrostatic Force Microscopy (SPP-EFM). An open-source MATLAB Graphical User Interface (GUI) for images acquisition, processing and analysis has been developed. The technique is tested with Indium Tin Oxide (ITO) and with poly(3-hexylthiophene) (P3HT) nanowires for organic transistor applications.

  2. Tips Under the Skin: A Simple Modification of Extension Block Pinning for Mallet Fractures.

    PubMed

    Shin, Seung-Han; Lee, Yong-Suk; Kang, Jin-Woo; Kang, Wonwoo; Chung, Yang-Guk

    2018-03-01

    Pins exposed out of the skin after surgery for mallet fractures keep patients from washing their hands. The authors buried the tips of all pins under the skin while performing extension block pinning for 14 patients with mallet fractures. The patients were allowed to wash their hands 4 to 5 days postoperatively, without any dressing or splinting. The pins were removed at a mean of 8 weeks postoperatively. Solid union was achieved in all 14 fractures. No pull-out or subsidence of the pin was observed. No patient developed infection or other pin-related complications. Mean extension lag at final follow-up was 4°. [Orthopedics. 2018; 41(2):e299-e302.]. Copyright 2018, SLACK Incorporated.

  3. An effective technique to facilitate radiographic stone visualization with an internal stent during shock wave lithotripsy.

    PubMed

    Sundaram, C P; Saltzman, B

    1998-10-01

    We describe a simple method to assist stone localization during shock wave lithotripsy in the presence of a Double J stent. A 4F whistle tip ureteral catheter is passed alongside a previously inserted 6F Double J stent. The tip of the ureteral stent is positioned in the lower or mid third of the ureter. Contrast material is injected through the ureteral catheter during lithotripsy to assist stone localization. This technique has been successful in localization of poorly opacified renal stones during lithotripsy. Radiolucent and poorly calcified renal stones can be easily localized during shock wave lithotripsy, despite the presence of a Double J stent. No special catheters or stents are required for this technique.

  4. A statistical model of brittle fracture by transgranular cleavage

    NASA Astrophysics Data System (ADS)

    Lin, Tsann; Evans, A. G.; Ritchie, R. O.

    A MODEL for brittle fracture by transgranular cleavage cracking is presented based on the application of weakest link statistics to the critical microstructural fracture mechanisms. The model permits prediction of the macroscopic fracture toughness, KI c, in single phase microstructures containing a known distribution of particles, and defines the critical distance from the crack tip at which the initial cracking event is most probable. The model is developed for unstable fracture ahead of a sharp crack considering both linear elastic and nonlinear elastic ("elastic/plastic") crack tip stress fields. Predictions are evaluated by comparison with experimental results on the low temperature flow and fracture behavior of a low carbon mild steel with a simple ferrite/grain boundary carbide microstructure.

  5. Note: Design and fabrication of a simple versatile microelectrochemical cell and its accessories

    NASA Astrophysics Data System (ADS)

    Rajan, Viswanathan; Neelakantan, Lakshman

    2015-09-01

    A microelectrochemical cell housed in an optical microscope and custom-made accessories have been designed and fabricated, which allows performing spatially resolved corrosion measurements. The cell assembly was designed to directly integrate the reference electrode close to the capillary tip to avoid air bubbles. A hard disk along with an old optical microscope was re-engineered into a microgrinder, which made the vertical grinding of glass capillary tips very easy. A stepper motor was customized into a microsyringe pump to dispense a controlled volume of electrolyte through the capillary. A force sensitive resistor was used to achieve constant wetting area. The functionality of the developed instrument is demonstrated by studying μ-electrochemical behavior of worn surface on AA2014-T6 alloy.

  6. Guidelines for preparing software user documentation

    NASA Technical Reports Server (NTRS)

    Miller, Diane F.

    1987-01-01

    Clear, easy-to-use software user's manuals make strong demands on special technical communication techniques. Principles and guidelines are given for analyzing the audience and dealing with wide-ranging backgrounds of potential users. Types of information to be included in a complete manual are suggested, with a technique for creating a user-oriented rather than process-oriented organization. Accuracy verification is emphasized. Simple tips are gievn for formatting for quick comprehension and reference, for deciding on packaging, for creating helpful illustrations and examples, and for setting up clear and consistent conventions. Simple guidelines are offered for writing clearly and concisely and for editing.

  7. Significance of modeling internal damping in the control of structures

    NASA Technical Reports Server (NTRS)

    Banks, H. T.; Inman, D. J.

    1992-01-01

    Several simple systems are examined to illustrate the importance of the estimation of damping parameters in closed-loop system performance and stability. The negative effects of unmodeled damping are particularly pronounced in systems that do not use collocated sensors and actuators. An example is considered for which even the actuators (a tip jet nozzle and flexible hose) for a simple beam produce significant damping which, if ignored, results in a model that cannot yield a reasonable time response using physically meaningful parameter values. It is concluded that correct damping modeling is essential in structure control.

  8. Tip/tilt-compensated through-focus scanning optical microscopy

    NASA Astrophysics Data System (ADS)

    Lee, Jun Ho; Park, Jun Hyung; Jeong, Dohwan; Shin, Eun Ji; Park, Chris

    2016-11-01

    Through-Focus Optical Microscopy (TSOM), with nanometer scale lateral and vertical sensitivity matching those of scanning electron microscopy, has been demonstrated to be utilized for 3D inspection and metrology. There have been sensitivity and instability issues in acquiring through-focus images because TSOM 3D information is indirectly extracted by differentiating a target TSOM image from reference TSOM images. This paper first reports on the optical axis instability that occurs during the scanning process of TSOM when implemented in an existing patterned wafer inspection tool by moving the wafer plane; this is followed by quantitative confirmation of the optical/mechanical instability using a new TSOM tool on an optical bench with a Shack-Hartmann wavefront sensor and a tip/tilt sensor. Then, this paper proposes two tip/tilt compensated TSOM optical acquisition methods that can be applied with adaptive optics. The first method simply adopts a tip/tilt mirror with a quad cell in a simple closed loop, while the second method adopts a highorder deformable mirror with a Shack-Hartmann sensor. The second method is able to correct high-order residual aberrations as well as to perform through-focus scanning without z-axis movement, while the first method is easier to implement in pre-existing wafer inspection systems with only minor modification.

  9. Elimination of two viruses which interact synergistically from sweetpotato by shoot tip culture and cryotherapy.

    PubMed

    Wang, Q C; Valkonen, J P T

    2008-12-01

    Sweet potato chlorotic stunt virus (SPCSV; Closteroviridae) and Sweet potato feathery mottle virus (SPFMV; Potyviridae) interact synergistically and cause severe diseases in co-infected sweetpotato plants (Ipomoea batatas). Sweetpotato is propagated vegetatively and virus-free planting materials are pivotal for sustainable production. Using cryotherapy, SPCSV and SPCSV were eliminated from all treated single-virus-infected and co-infected shoot tips irrespective of size (0.5-1.5mm including 2-4 leaf primordia). While shoot tip culture also eliminated SPCSV, elimination of SPFMV failed in 90-93% of the largest shoot tips (1.5mm) using this technique. Virus distribution to different leaf primordia and tissues within leaf primordia in the shoot apex and petioles was not altered by co-infection of the viruses in the fully virus-susceptible sweetpotato genotype used. SPFMV was immunolocalized to all types of tissues and up to the fourth-youngest leaf primordium. In contrast, SPCSV was detected only in the phloem and up to the fifth leaf primordium. Because only cells in the apical dome of the meristem and the two first leaf primordia survived cryotherapy, all data taken together could explain the results of virus elimination. The simple and efficient cryotherapy protocol developed for virus elimination can also be used for preparation of sweetpotato materials for long-term preservation.

  10. Tips for a physician in getting the right job, part XXIII: starting a new job.

    PubMed

    Harolds, Jay A

    2015-06-01

    After signing a contract, the new doctor has much to do before starting work, such as licensing, credentialing, finding a new home, and moving. There are important tips for a new physician in doing well in a job, such as asking for frequent feedback, doing at least one's share of the work, being at the job and available when expected, being sensitive and helpful to the needs of patients and members of the health care team, cultivating relationships, and in some cases, marketing.

  11. Does Bedside Sonography Effectively Identify Nasogastric Tube Placements in Pediatric Critical Care Patients?

    PubMed

    Atalay, Yunus Oktay; Aydin, Ramazan; Ertugrul, Omer; Gul, Selim Baris; Polat, Ahmet Veysel; Paksu, Muhammet Sukru

    2016-12-01

    A nasogastric tube (NGT) insertion is a common procedure in intensive care units, with some serious complications that result from the malposition of the NGT tip. This pilot study was designed to investigate the efficiency of ultrasound in verifying correct NGT placement and to compare these results with radiographic findings. This was a single-center, double-blind prospective study of patients who had received an NGT in the pediatric critical care unit. Twenty-one patients aged 1 month to 18 years were included in this study. All NGTs were inserted by the same critical care physician. After insertion, the physician first confirmed NGT placement by the auscultation of the epigastrium following the insufflation of air. Confirmation was supplemented with an abdominal radiograph. A radiologist who was unaware of the radiographic findings performed bedside sonography on all patients and verified the location of the NGTs. The findings from these 2 physicians were then compared. NGTs were inserted without any complications, and none of the NGTs were positioned in the respiratory tract in any of the patients. All NGT tips were visualized by radiography and sonography with a sensitivity of 100%. Bedside sonography performed by a radiologist is an effective and sensitive diagnostic procedure for confirming the correct NGT position in patients in the pediatric critical care unit.

  12. Intravascular Ultrasound in the Creation of Transhepatic Portosystemic Shunts Reduces Needle Passes, Radiation Dose, and Procedure Time: A Retrospective Study of a Single-Institution Experience.

    PubMed

    Kao, Steven D; Morshedi, Maud M; Narsinh, Kazim H; Kinney, Thomas B; Minocha, Jeet; Picel, Andrew C; Newton, Isabel; Rose, Steven C; Roberts, Anne C; Kuo, Alexander; Aryafar, Hamed

    2016-08-01

    To assess whether intravascular ultrasound (US) guidance impacts number of needle passes, contrast usage, radiation dose, and procedure time during creation of transjugular intrahepatic portosystemic shunts (TIPS). Intravascular US-guided creation of TIPS in 40 patients was retrospectively compared with conventional TIPS in 49 patients between February 2010 and November 2015 at a single tertiary care institution. Patient sex and age, etiology of liver disease (hepatitis C virus, alcohol abuse, nonalcoholic steatohepatitis), severity of liver disease (mean Model for End-Stage Liver Disease score), and indications for TIPS (variceal bleeding, refractory ascites, refractory hydrothorax) in conventional and intravascular US-guided cases were recorded. The two groups were well matched by sex, age, etiology of liver disease, Child-Pugh class, Model for End-Stage Liver Disease scores, and indication for TIPS (P range = .19-.94). Fewer intrahepatic needle passes were required in intravascular US-guided TIPS creation compared with conventional TIPS (2 passes vs 6 passes, P < .01). Less iodinated contrast material was used in intravascular US cases (57 mL vs 140 mL, P < .01). Radiation exposure, as measured by cumulative dose, dose area product, and fluoroscopy time, was reduced with intravascular US (174 mGy vs 981 mGy, P < .01; 3,793 μGy * m(2) vs 21,414 μGy * m(2), P < .01; 19 min vs 34 min, P < .01). Procedure time was shortened with intravascular US (86 min vs 125 min, P < .01). Intravascular US guidance resulted in fewer intrahepatic needle passes, decreased contrast medium usage, decreased radiation dosage, and shortened procedure time in TIPS creation. Copyright © 2016 SIR. All rights reserved.

  13. Disinfection of Tonometers: A Report by the American Academy of Ophthalmology.

    PubMed

    Junk, Anna K; Chen, Philip P; Lin, Shan C; Nouri-Mahdavi, Kouros; Radhakrishnan, Sunita; Singh, Kuldev; Chen, Teresa C

    2017-12-01

    To examine the efficacy of various disinfection methods for reusable tonometer prisms in eye care and to highlight how disinfectants can damage tonometer tips and cause subsequent patient harm. Literature searches were conducted last in October 2016 in the PubMed and the Cochrane Library databases for original research investigations. Reviews, non-English language articles, nonophthalmology articles, surveys, and case reports were excluded. The searches initially yielded 64 unique citations. After exclusion criteria were applied, 10 laboratory studies remained for this review. Nine of the 10 studies used tonometer prisms and 1 used steel discs. The infectious agents covered in this assessment include adenovirus 8 and 19, herpes simplex virus (HSV) 1 and 2, human immunodeficiency virus 1, hepatitis C virus, enterovirus 70, and variant Creutzfeldt-Jakob disease. All 4 studies of adenovirus 8 concluded that after sodium hypochlorite (dilute bleach) disinfection, the virus was undetectable, but only 2 of the 4 studies found that 70% isopropyl alcohol (e.g., alcohol wipes or soaks) eradicated all viable virus. All 3 HSV studies concluded that both sodium hypochlorite and 70% isopropyl alcohol eliminated HSV. Ethanol, 70% isopropyl alcohol, dilute bleach, and mechanical cleaning all lack the ability to remove cellular debris completely, which is necessary to prevent prion transmission. Therefore, single-use tonometer tips or disposable tonometer covers should be considered when treating patients with suspected prion disease. Damage to tonometer prisms can be caused by sodium hypochlorite, 70% isopropyl alcohol, 3% hydrogen peroxide, ethyl alcohol, water immersion, ultraviolet light, and heat exposure. Disinfectants can cause tonometer tips to swell and crack by dissolving the glue that holds the hollow tip together. The tonometer tip cracks can irritate the cornea, harbor microbes, or allow disinfectants to enter the interior of the tonometer tip. Sodium hypochlorite (dilute bleach) offers effective disinfection against adenovirus and HSV, the viruses commonly associated with nosocomial outbreaks in eye care. Tonometer prisms should be examined regularly for signs of damage. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  14. Four Medication Safety Tips for Older Adults

    MedlinePlus

    ... are experiencing could be due to medications. 4. Review Medications with Your Health Care Provider Ideally, you ... taking (if any). If it’s not possible to review medications at each visit, schedule at least one ...

  15. African-American Hair: Tips for Everyday Care

    MedlinePlus

    ... Us Media contacts Advertising contacts AAD logo Advertising, marketing and sponsorships Legal notice Copyright © 2018 American Academy ... prohibited without prior written permission. AAD logo Advertising, marketing and sponsorships Legal notice Copyright © 2017 American Academy ...

  16. Coping with Rosacea: Managing Psychosocial Aspects of Rosacea

    MedlinePlus

    ... System Vascular Changes Demodex & Microbes Bibliography Genetics The Ecology of Your Face It Works for Me: Patient ... Tips Skin Care & Cosmetics Causes of Rosacea The Ecology of Your Face It Works for Me: Patient ...

  17. Smooth School Transitions: Tips for Military Families

    MedlinePlus

    ... family separation, and transition. Additional Information from HealthyChildren.org: Deployment and Children Military Families: Child Care Support ... CNN.com) Coming Together Around Military Families (zerotothree.org) FOCUS (Families OverComing Under Stress™) FOX News Talks ...

  18. Eye Drop Tips

    MedlinePlus

    ... Size Small Text Medium Text Large Text Contrast Dark on Light Light on Dark Donate Search Menu Donate What is Glaucoma? Care ... Low Vision Resources Medication Guide Resources on the Web » See All Articles Where the Money Goes Have ...

  19. CFC (Comment-First-Coding)--A Simple yet Effective Method for Teaching Programming to Information Systems Students

    ERIC Educational Resources Information Center

    Sengupta, Arijit

    2009-01-01

    Programming courses have always been a difficult part of an Information Systems curriculum. While we do not train Information Systems students to be developers, understanding how to build a system always gives students an added perspective to improve their system design and analysis skills. This teaching tip presents CFC (Comment-First-Coding)--a…

  20. Four-Wheel Vehicle Suspension System

    NASA Technical Reports Server (NTRS)

    Bickler, Donald B.

    1990-01-01

    Four-wheel suspension system uses simple system of levers with no compliant components to provide three-point suspension of chassis of vehicle while maintaining four-point contact with uneven terrain. Provides stability against tipping of four-point rectangular base, without rocking contact to which rigid four-wheel frame susceptible. Similar to six-wheel suspension system described in "Articulated Suspension Without Springs" (NPO-17354).

  1. Measuring Thicknesses of Wastewater Films

    NASA Technical Reports Server (NTRS)

    Schubert, F. H.; Davenport, R. J.

    1987-01-01

    Sensor determines when thickness of film of electrically conductive wastewater on rotating evaporator drum exceeds preset value. Sensor simple electrical probe that makes contact with liquid surface. Made of materials resistant to chemicals in liquid. Mounted on shaft in rotating cylinder, liquid-thickness sensor extends toward cylinder wall so tip almost touches. Sensor body accommodates probe measuring temperature of evaporated water in cylinder.

  2. Get Them Talking! Using Student-Led Book Talks in the Primary Grades

    ERIC Educational Resources Information Center

    Hudson, Alida K.

    2016-01-01

    This teaching tip details one teacher's implementation of student-led book talks in her primary-grade classroom. The author describes a simple gradual-release method that she has successfully used with her students in order to get them talking about the books that they are reading independently. She found that when used in the readers' workshop…

  3. Pipette-tip solid-phase extraction using poly(1-vinylimidazole-co-trimethylolpropane trimethacrylate) as a new molecularly imprinted polymer in the determination of avermectins and milbemycins in fruit juice and water samples.

    PubMed

    Teixeira, Roseane Andrade; Flores, Diego Hernando Ângulo; da Silva, Ricky Cássio Santos; Dutra, Flávia Viana Avelar; Borges, Keyller Bastos

    2018-10-01

    A simple HPLC method was developed for the determination of abamectin (ABA), eprinomectin (EPR), and moxidectin (MOX). Pipette-tip molecularly imprinted polymer solid-phase extraction (PT-MIP-SPE) using poly(1-vinylimidazole-co-trimethylolpropane trimethacrylate) as a selective adsorbent material was studied in detail, including the washing solvent, type and volume of eluent, pH, quantity of adsorbent material and sample volume. The performance criteria for linearity, sensitivity, precision, accuracy, recovery, robustness and stability have been assessed and were within the recommended guidelines. The mean extraction recoveries/relative standard deviation for ABA 1b, EPR, ABA 1a and MOX were 98.77 ± 3.82%, 88.19 ± 2.57%, 110.54 ± 1.52% and 100.42 ± 0.59%, respectively. Finally, the results proved that PT-MIP-SPE coupled to HPLC-UV is an economical, simple and easy-to-perform technique, and presented a high potential for extraction of macrocyclic lactones in mineral water and grape and juice samples. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Contact stiffness and damping of liquid films in dynamic atomic force microscope

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Rong-Guang; Leng, Yongsheng, E-mail: leng@gwu.edu

    2016-04-21

    The mechanical properties and dissipation behaviors of nanometers confined liquid films have been long-standing interests in surface force measurements. The correlation between the contact stiffness and damping of the nanoconfined film is still not well understood. We establish a novel computational framework through molecular dynamics (MD) simulation for the first time to study small-amplitude dynamic atomic force microscopy (dynamic AFM) in a simple nonpolar liquid. Through introducing a tip driven dynamics to mimic the mechanical oscillations of the dynamic AFM tip-cantilever assembly, we find that the contact stiffness and damping of the confined film exhibit distinct oscillations within 6-7 monolayermore » distances, and they are generally out-of-phase. For the solid-like film with integer monolayer thickness, further compression of the film before layering transition leads to higher stiffness and lower damping, while much lower stiffness and higher damping occur at non-integer monolayer distances. These two alternating mechanisms dominate the mechanical properties and dissipation behaviors of simple liquid films under cyclic elastic compression and inelastic squeeze-out. Our MD simulations provide a direct picture of correlations between the structural property, mechanical stiffness, and dissipation behavior of the nanoconfined film.« less

  5. What advice is given to newly qualified doctors on Twitter? An analysis of #TipsForNewDocs tweets.

    PubMed

    Rashid, Mohammed Ahmed; McKechnie, Doug; Gill, Deborah

    2018-07-01

    Twitter is a social media platform on which users post very brief messages that can be rapidly communicated across wide geographical areas and audiences. Many doctors use Twitter for personal as well as professional communications and networking. The #TipsForNewDocs hashtag is used on Twitter to give advice to newly qualified doctors as they commence their careers. This study explores the nature and focus of such advice. An analysis of Twitter activity containing the #TipsForNewDocs hashtag was performed using Symplur health care analytics software. Tweets sent during a peak 48-hour period in 2016 (immediately preceding the first day of work for newly qualified UK doctors) were studied. The geographical locations and professional backgrounds of participants were categorised and the content of tweets was subjected to thematic analysis. During 1 and 2 August 2016, 661 unique #TipsForNewDocs tweets were posted. A total of 621 (94.0%) were posted by people in the UK; 522 (79.0%) were posted by doctors, and the remainder by allied health care professionals and patients. The majority of included tweets focused on aspects of professional development, improving personal or professional knowledge, particularly tacit knowledge, and developing 'know-how'. These aspects of professional knowledge have previously been described as fundamental to professional education and training. However, a significant subset of tweets focused on accelerating socialisation into the profession, an essential step in joining a professional community. The tweets relating to socialisation were often humorous and colloquial in nature. Despite their brief and often jocular nature, #TipsForNewDocs tweets provided meaningful advice for newcomers to the profession, often focusing on tacit learning and professional socialisation. Hashtag-driven enquiries can be a valuable and time-efficient way of accessing and sharing tacitly held knowledge. Social media content analysis can provide valuable insights into key educational issues. © 2018 John Wiley & Sons Ltd and The Association for the Study of Medical Education.

  6. Modifiable risk factors for typhoid intestinal perforations during a large outbreak of typhoid fever, Kampala Uganda, 2015.

    PubMed

    Bulage, Lilian; Masiira, Ben; Ario, Alex R; Matovu, Joseph K B; Nsubuga, Peter; Kaharuza, Frank; Nankabirwa, Victoria; Routh, Janell; Zhu, Bao-Ping

    2017-09-25

    Between January and June, 2015, a large typhoid fever outbreak occurred in Kampala, Uganda, with 10,230 suspected cases. During the outbreak, area surgeons reported a surge in cases of typhoid intestinal perforation (TIP), a complication of typhoid fever. We conducted an investigation to characterize TIP cases and identify modifiable risk factors for TIP. We defined a TIP case as a physician-diagnosed typhoid patient with non-traumatic terminal ileum perforation. We identified cases by reviewing medical records at all five major hospitals in Kampala from 2013 to 2015. In a matched case-control study, we compared potential risk factors among TIP cases and controls; controls were typhoid patients diagnosed by TUBEX TF, culture, or physician but without TIP, identified from the outbreak line-list and matched to cases by age, sex and residence. Cases and controls were interviewed using a standard questionnaire from 1st -23rd December 2015. We used conditional logistic regression to assess risk factors for TIP and control for confounding. Of the 88 TIP cases identified during 2013-2015, 77% (68/88) occurred between January and June, 2015; TIPs sharply increased in January and peaked in March, coincident with the typhoid outbreak. The estimated risk of TIP was 6.6 per 1000 suspected typhoid infections (68/10,230). The case-fatality rate was 10% (7/68). Cases sought care later than controls; Compared with 29% (13/45) of TIP cases and 63% (86/137) of controls who sought treatment within 3 days of onset, 42% (19/45) of cases and 32% (44/137) of controls sought treatment 4-9 days after illness onset (OR adj  = 2.2, 95%CI = 0.83-5.8), while 29% (13/45) of cases and 5.1% (7/137) of controls sought treatment ≥10 days after onset (OR adj  = 11, 95%CI = 1.9-61). 68% (96/141) of cases and 23% (23/100) of controls had got treatment before being treated at the treatment centre (OR adj  = 9.0, 95%CI = 1.1-78). Delay in seeking treatment increased the risk of TIPs. For future outbreaks, we recommended aggressive community case-finding, and informational campaigns in affected communities and among local healthcare providers to increase awareness of the need for early and appropriate treatment.

  7. Trials of Improved Practices (TIPs) to Enhance the Dietary and Iron-Folate Intake during Pregnancy- A Quasi Experimental Study among Rural Pregnant Women of Varanasi, India.

    PubMed

    Shivalli, Siddharudha; Srivastava, Ratan Kumar; Singh, Gyan Prakash

    2015-01-01

    Behavior Change Communications (BCC) play a decisive role in modifying socio-cultural norms affecting the perception and nutritional practices during pregnancy. To examine the effectiveness of 'Trials of Improved Practices' (TIPs) on dietary and iron-folate intake during pregnancy. Community based quasi experimental study with a control group. Four villages of Chiraigaon Community Development Block of Varanasi, India from May 2010 and recruited from August 2010. End line assessment, after 12 weeks of intervention, was completed in April 2011. Pregnant women in 13-28 weeks of gestation. TIPs was implemented in addition to ongoing essential obstetric care services in two villages through 3 home (assessment, negotiation and evaluation) visits and only assessment and evaluation visits in the other two control villages. Interpersonal communication, endorsing the active participation of family members and home based reminder materials were the TIPs based strategies. The effect of TIPs was assessed by comparing key outcome variables at baseline and after 12 weeks of intervention. Hemoglobin%, anemia prevalence, weight gain, compliance for iron-folate supplementation and dietary intake of calorie, protein, calcium and iron. A total of 86 participants completed the study. At the end, mean hemoglobin levels were 11.5±1.24 g/dl and 10.37±1.38 g/dl in the TIPs and control groups, respectively. The prevalence of anemia reduced by half in TIPs group and increased by 2.4% in the control group. Weight gain (grams/week) was significantly (p<0.01) higher in TIPs group (326.9±91.8 vs. 244.6±97.4). More than 85% of the PW in TIPs group were compliant for Iron-folate and only 38% were compliant among controls. The mean intake of protein increased by 1.78gm in intervention group and decreased by 1.81 gm in controls (p<0.05). More than two thirds of PW in TIPs group were taking one extra meal and only one third of controls were doing the same. TIPs found to be an effective approach to improve the nutritional status of pregnant women in the study area. TIPs strategy could be further explored on larger sample representing different socio-cultural and geographical areas. Clinical Trial Registry of India CTRI/2015/02/005517.

  8. Velocity-jump instabilities in Hele-Shaw flow of associating polymer solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vlad, D.H.; Ignes-Mullol, J.; Maher, J.V.

    We study fracturelike flow instabilities that arise when water is injected into a Hele-Shaw cell filled with aqueous solutions of associating polymers. We explore various polymer architectures, molecular weights, and solution concentrations. Simultaneous measurements of the finger tip velocity and of the pressure at the injection point allow us to describe the dynamics of the finger in terms of the {open_quotes}finger mobility,{close_quotes} which relates the velocity to the pressure gradient. The flow discontinuities, characterized by jumps in the finger tip velocity, which are observed in experiments with some of the polymer solutions, can be modeled by using a nonmonotonic dependencemore » between a characteristic shear stress and the shear rate at the tip of the finger. A simple model, which is based on a viscosity function containing both a Newtonian and a non-Newtonian component, and which predicts nonmonotonic regions when the non-Newtonian component of the viscosity dominates, is shown to agree with the experimental data. {copyright} {ital 1999} {ital The American Physical Society}« less

  9. Improved efficiency of ZnO hierarchical particle based dye sensitized solar cell by incorporating thin passivation layer in photo-anode

    NASA Astrophysics Data System (ADS)

    Das, Priyanka; Mondal, Biswanath; Mukherjee, Kalisadhan

    2018-01-01

    Present article describes the DSSC performances of photo-anodes prepared using hydrothermal route derived ZnO particles having dissimilar morphologies i.e. simple micro-rod and nano-tips decorated micro-rod. The surface of nano-tips decorated micro-rod is uneven and patterned which facilitate more dye adsorption and better scattering of the incident light resulting superior photo-conversion efficiency (PCE) ( η 1.09%) than micro-rod ZnO ( η 0.86%). To further improve the efficiency of nano-tips decorated micro-rod ZnO based DSSC, thin passivation layer of ZnO is introduced in the corresponding photo-anode and a higher PCE ( η 1.29%) is achieved. The compact thin passivation layer here expedites the transportation of photo-excited electrons, restricts the undesired recombination reactions and prevents the direct contact of electrolyte with conducting substrates. Attempt is made to understand the effect of passivation layer on the transportation kinetics of photo-excited electrons by analyzing the electrochemical impedance spectra of the developed cells.

  10. Painless needle insertion in regional anesthesia of the eye.

    PubMed

    Vaalamo, M O; Paloheimo, M P; Nikki, P H

    1995-04-01

    We examined a new technique of applying topical anesthetic with cotton tip sticks to the conjunctiva before needle insertion in regional anesthesia of the eye. Oxybuprocaine 0.4% and lidocaine 4% were compared with balanced salt solution (BSS) as topical anesthetics of the conjunctiva in Study 1. Ninety patients were randomly assigned into three groups (n = 30) to receive one of the three topical anesthetics in a double-blind manner. Pain of the needle insertions was measured with visual analog scale score (VAS) and quantitative surface electromography (qEMG). Both oxybuprocaine and lidocaine reduced pain significantly when compared to BSS. In Study 2, with healthy volunteers, we compared our previous practice of merely applying three consecutive drops of oxybuprocaine on the conjunctiva before needle insertions to the new technique of placing additional cotton tip sticks soaked in oxybuprocaine on the conjunctiva. We found the needle insertion virtually pain free when the cotton tip sticks were added to the topical anesthesia. The use of this simple method of topical anesthesia before the eye block increases patient comfort significantly.

  11. Fabrication of PVDF-based blend membrane with a thin hydrophilic deposition layer and a network structure supporting layer via the thermally induced phase separation followed by non-solvent induced phase separation process

    NASA Astrophysics Data System (ADS)

    Wu, Zhiguo; Cui, Zhenyu; Li, Tianyu; Qin, Shuhao; He, Benqiao; Han, Na; Li, Jianxin

    2017-10-01

    A simple strategy of thermally induced phase separation followed by non-solvent induced phase separation (TIPS-NIPS) is reported to fabricate poly (vinylidene fluoride) (PVDF)-based blend membrane. The dissolved poly (styrene-co-maleic anhydride) (SMA) in diluent prevents the crystallization of PVDF during the cooling process and deposites on the established PVDF matrix in the later extraction. Compared with traditional coating technique, this one-step TIPS-NIPS method can not only fabricate a supporting layer with an interconnected network structure even via solid-liquid phase separation of TIPS, but also form a uniform SMA skin layer approximately as thin as 200 nm via surface deposition of NIPS. Besides the better hydrophilicity, what's interesting is that the BSA rejection ratio increases from 48% to 94% with the increase of SMA, which indicates that the separation performance has improved. This strategy can be conveniently extended to the creation of firmly thin layer, surface functionalization and structure controllability of the membrane.

  12. Determination of Stress Coefficient Terms in Cracked Solids for Monoclinic Materials with Plane Symmetry at x3 = 0

    NASA Technical Reports Server (NTRS)

    Yuan, F. G.

    1998-01-01

    Determination of all the coefficients in the crack tip field expansion for monoclinic materials under two-dimensional deformation is presented in this report. For monoclinic materials with a plane of material symmetry at x(sub 3) = 0, the in-plane deformation is decoupled from the anti-plane deformation. In the case of in-plane deformation, utilizing conservation laws of elasticity and Betti's reciprocal theorem, together with selected auxiliary fields, T-stress and third-order stress coefficients near the crack tip are evaluated first from path-independent line integrals. To determine the T-stress terms using the J-integral and Betti's reciprocal work theorem, auxiliary fields under a concentrated force and moment acting at the crack tip are used respectively. Through the use of Stroh formalism in anisotropic elasticity, analytical expressions for all the coefficients including the stress intensity factors are derived in a compact form that has surprisingly simple structure in terms of the Barnett-Lothe tensors, L. The solution forms for degenerated materials, orthotropic, and isotropic materials are presented.

  13. Fracture Mechanics Analyses for Interface Crack Problems - A Review

    NASA Technical Reports Server (NTRS)

    Krueger, Ronald; Shivakumar, Kunigal; Raju, Ivatury S.

    2013-01-01

    Recent developments in fracture mechanics analyses of the interfacial crack problem are reviewed. The intent of the review is to renew the awareness of the oscillatory singularity at the crack tip of a bimaterial interface and the problems that occur when calculating mode mixity using numerical methods such as the finite element method in conjunction with the virtual crack closure technique. Established approaches to overcome the nonconvergence issue of the individual mode strain energy release rates are reviewed. In the recent literature many attempts to overcome the nonconvergence issue have been developed. Among the many approaches found only a few methods hold the promise of providing practical solutions. These are the resin interlayer method, the method that chooses the crack tip element size greater than the oscillation zone, the crack tip element method that is based on plate theory and the crack surface displacement extrapolation method. Each of the methods is validated on a very limited set of simple interface crack problems. However, their utility for a wide range of interfacial crack problems is yet to be established.

  14. Effective Use of Social Media in Communicating Climate Science

    NASA Astrophysics Data System (ADS)

    Sinclair, P. W.

    2012-12-01

    The internet and social media have been a critical vector for misinformation on climate change. Scientists have not always been proactive or effective in utilizing the medium to bring attention to the best science, to correct misinformation and overcome urban myths. Similarly, mainstream journalists have been handicapped in dealing with the wide open nature of the medium, and often muted by editorial concerns or budget restrictions. Independent communicators who are highly motivated can make inroads in this area by using the internet's immediacy and connectivity to consistently connect viewers and readers to reliable information. Over the last 4 years, I have developed a series of you tube videos, made deliberately provocative to engage the internet's confrontational culture, but carefully crafted to bring the best science into the freewheeling community. In doing so, I have won the confidence of leading climate scientists, and in some cases assisted them in clarifying their message. This presentation will share simple tips, useful practices, and effective strategies for making complex material more clear and user friendly, and help scientists better convey the stories hidden in their data.

  15. Prevention of poison ivy dermatitis with oral homeopathic Rhus toxicodendron.

    PubMed

    Signore, Robert Joseph

    2017-01-15

    Acute allergic contact dermatitis to poison ivy is acommon and miserable dermatosis which affectsmillions of Americans each year. Preventativemeasures, such as avoidance, protective clothing,barrier creams, soaps, and solvents often fail despiteour patients' best attempts. Severe allergic reactionsto poison ivy are a significant source of decreasedemployee productivity owing to inability to work anda major health care expenditure. Patients may haveto leave their jobs and discontinue favorite outdoorrecreational activities as a result of severe urushiolsensitivity. Thus, a simple and effective method ofpreventing poison ivy dermatitis would be of greatbenefit to clinical dermatologists and their patients.Complementary and alternative medical practitionerscommonly prescribe homeopathic poison ivyproducts by mouth for the prevention of poisonivy dermatitis. Yet, conventional dermatologists aremostly unaware of this little known clinical pearl. Theauthor discusses two open studies and anecdotalexperience with administration of homeopathicpoison ivy in the prevention of acute allergic contactdermatitis related to poison ivy exposure. Potentialadvantages could include patient acceptability,ease of administration, affordability, and availability.Randomized clinical trials are needed to furtherevaluate the safety and efficacy of this interesting andpromising clinical tip.

  16. Multi-phase-fluid discrimination with local fibre-optical probes: I. Liquid/liquid flows

    NASA Astrophysics Data System (ADS)

    Fordham, E. J.; Holmes, A.; Ramos, R. T.; Simonian, S.; Huang, S.-M.; Lenn, C. P.

    1999-12-01

    We demonstrate the use of a novel design of fibre-optical sensor (or `local probe') for immiscible-fluid discrimination in multi-phase flows. These probes are made from standard silica fibres with plane oblique facets polished at the fibre tip, with various surface treatments, including a crucial one for wettability control. Total internal reflection is used to distinguish drops, bubbles or other regions of fluid in multi-phase flows, on the basis of refractive-index contrast. Such probes have quasi-binary outputs; we demonstrate in this paper their use in distinguishing water from oil (kerosene) in oil/water two-phase flows and compare the results with those obtained from a simple cleaved fibre relying on the (small) difference in Fresnel reflectivity for discrimination. Quantitative accuracy is demonstrated by comparison of profiles, across a pipe diameter, of local, time-averaged volume fractions (`hold-ups'), with pipe-averaged hold-ups determined from a carefully calibrated gradio-manometer in a fully developed region of the flow. Companion papers deal with the sensors used and results achieved in gas/liquid flows and three-phase flows.

  17. Military Families: Child Care Support During Deployments

    MedlinePlus

    ... us what to do.” Additional Information from HealthyChildren.org: Deployment and Children Smooth School Transitions: Tips for ... CNN.com) Coming Together Around Military Families (zerotothree.org) FOCUS (Families OverComing Under Stress™) FOX News Talks ...

  18. A simple device for teaching direct ophthalmoscopy to primary care practitioners.

    PubMed

    Chung, Kelly D; Watzke, Robert C

    2004-09-01

    Ophthalmoscopy, a valuable skill for primary care practitioners, can be challenging to learn. A simple and inexpensive device for teaching direct ophthalmoscopy to primary care practitioners is described. Device description. Cylindrical plastic canisters were altered to have an artificial pupil at one end and a replaceable fundus photograph at the other end to simulate the mechanics of performing direct ophthalmoscopy on a real eye. These were tested for ease of use by primary care students. The devices to aid in teaching ophthalmoscopy proved to be simple and inexpensive to construct. They allowed students to practice direct ophthalmoscopy technique and identification of funduscopic abnormalities. This simple device for teaching direct ophthalmoscopy to primary care practitioners is inexpensive to create and is a valuable aid for teaching direct ophthalmoscopy to primary care practitioners.

  19. Improved Patency of Transjugular Intrahepatic Portosystemic Shunt: The Efficacy of Cilostazol for the Prevention of Pseudointimal Hyperplasia in Swine TIPS Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Sang Woo; Cha, In Ho; Kim, Chul Hwan

    Purpose. To investigate the efficacy of oral administration of cilostazol to inhibit pseudointimal/intimal hyperplasia in swine TIPS models. Methods. Successful TIPS creation was carried out in 11 of 12 healthy young pigs (20-25 kg). In the treatment group (n = 6), both cilostazol and aspirin were administered daily, from the first day of TIPS creation. The control group (n = 5) was administered only aspirin. The animals were followed-up for 2 weeks and then killed. The specimen (including portal vein, hepatic parenchymal tract, hepatic vein, and inferior vena cava) and stents were carefully bisected in a longitudinal fashion. The controlmore » group was compared with the treatment group by means of a gross and histologic evaluation of the degree of pseudointimal/intimal hyperplasia in the shunt. Results. At the gross evaluation, the control group showed considerably more pseudointimal/intimal hyperplasia than the treatment group. Using microscopic evaluation, there was a statistically significant difference (p < 0.05) in the mean maximum pseudointimal/intimal hyperplasia thickness between the control group (2.97 {+-} 0.33 mm) and treatment group (0.73 {+-} 0.27 mm). Conclusion. Oral administration of cilostazol may have been effective in reducing pseudointimal/intimal hyperplasia in swine TIPS models.« less

  20. Label-free electrical quantification of amplified nucleic acids through nanofluidic diodes.

    PubMed

    Liu, Yifan; Yobas, Levent

    2013-12-15

    A label-free method of quantifying nucleic acids in polymerase chain reaction (PCR) is described and could be the basis for miniaturized devices that can amplify and detect target nucleic acids in real time. The method takes advantage of ionic current rectification effect discovered in nanofluidic channels exhibiting a broken symmetry in electrochemical potential - nanofluidic diodes. Nanofluidic diodes are prototyped here on nanopipettes readily pulled from individual thin-walled glass capillaries for a proof of concept demonstration yet the basic concept would be applicable to ionic rectifiers constructed through other means. When a nanopipette modified in the tip region with cationic polyelectrolytes is presented with an unpurified PCR product, the tip surface electrostatically interacts with the amplicons and modulates its ionic rectification direction in response to the intrinsic charge of those adsorbed. Modulations are gradual and correlate well with the mass concentration of the amplicons above 2.5 ng/μL, rather than their sizes, with adequate discrimination against the background. Moreover, the tip surface, following a measurement, is regenerated through a layer-by-layer assembly of cationic polyelectrolytes and amplicons. The regenerated tips are capable of measuring distinct mass concentrations without signs of noticeable degradation in sensitivity. Further, the tips are shown capable of reproducing the amplification curve of real-time PCR through sequential steps of surface regeneration and simple electrical readout during the intermediate reaction stages. This suggests that nanopipettes as nanofluidic diodes are at a capacity to be employed for monitoring the PCR progress. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Determination of Wind Turbine Near-Wake Length Based on Stability Analysis

    NASA Astrophysics Data System (ADS)

    Sørensen, Jens N.; Mikkelsen, Robert; Sarmast, Sasan; Ivanell, Stefan; Henningson, Dan

    2014-06-01

    A numerical study on the wake behind a wind turbine is carried out focusing on determining the length of the near-wake based on the instability onset of the trailing tip vortices shed from the turbine blades. The numerical model is based on large-eddy simulations (LES) of the Navier-Stokes equations using the actuator line (ACL) method. The wake is perturbed by applying stochastic or harmonic excitations in the neighborhood of the tips of the blades. The flow field is then analyzed to obtain the stability properties of the tip vortices in the wake of the wind turbine. As a main outcome of the study it is found that the amplification of specific waves (traveling structures) along the tip vortex spirals is responsible for triggering the instability leading to wake breakdown. The presence of unstable modes in the wake is related to the mutual inductance (vortex pairing) instability where there is an out-of-phase displacement of successive helix turns. Furthermore, using the non-dimensional growth rate, it is found that the pairing instability has a universal growth rate equal to π/2. Using this relationship, and the assumption that breakdown to turbulence occurs once a vortex has experienced sufficient growth, we provide an analytical relationship between the turbulence intensity and the stable wake length. The analysis leads to a simple expression for determining the length of the near wake. This expression shows that the near wake length is inversely proportional to thrust, tip speed ratio and the logarithmic of the turbulence intensity.

  2. Studies of ionic current rectification using polyethyleneimines coated glass nanopipettes.

    PubMed

    Liu, Shujuan; Dong, Yitong; Zhao, Wenbo; Xie, Xiang; Ji, Tianrong; Yin, Xiaohong; Liu, Yun; Liang, Zhongwei; Momotenko, Dmitry; Liang, Dehai; Girault, Hubert H; Shao, Yuanhua

    2012-07-03

    The modification of glass nanopipettes with polyethyleneimines (PEIs) has been successfully achieved by a relatively simple method, and the smallest tip opening is around 3 nm. Thus, in a much wider range of glass pipettes with radii from several nanometers to a few micrometers, the ion current rectification (ICR) phenomenon has been observed. The influences of different KCl concentrations, pH values, and tip radii on the ICR are investigated in detail. The sizes of PEIs have been determined by dynamic light scattering, and the effect of the sizes of PEIs for the modification, especially for a few nanometer-pipettes in radii, is also discussed. These findings systemically confirm and complement the theoretical model and provide a platform for possible selectively molecular detection and mimic biological ion channels.

  3. Visualization and quantification of magnetic nanoparticles into vesicular systems by combined atomic and magnetic force microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dong, C.; Department of Physics, SAPIENZA University of Rome, Piazzale A. Moro 5, 00185, Rome; Corsetti, S.

    2015-06-23

    We report a phenomenological approach for the quantification of the diameter of magnetic nanoparticles (MNPs) incorporated in non-ionic surfactant vesicles (niosomes) using magnetic force microscopy (MFM). After a simple specimen preparation, i.e., by putting a drop of solution containing MNPs-loaded niosomes on flat substrates, topography and MFM phase images are collected. To attempt the quantification of the diameter of entrapped MNPs, the method is calibrated on the sole MNPs deposited on the same substrates by analyzing the MFM signal as a function of the MNP diameter (at fixed tip-sample distance) and of the tip-sample distance (for selected MNPs). After calibration,more » the effective diameter of the MNPs entrapped in some niosomes is quantitatively deduced from MFM images.« less

  4. The SERS and TERS effects obtained by gold droplets on top of Si nanowires.

    PubMed

    Becker, M; Sivakov, V; Andrä, G; Geiger, R; Schreiber, J; Hoffmann, S; Michler, J; Milenin, A P; Werner, P; Christiansen, S H

    2007-01-01

    We show that hemispherical gold droplets on top of silicon nanowires when grown by the vapor-liquid-solid (VLS) mechanism, can produce a significant enhancement of Raman scattered signals. Signal enhancement for a few or even just single gold droplets is demonstrated by analyzing the enhanced Raman signature of malachite green molecules. For this experiment, trenches (approximately 800 nm wide) were etched in a silicon-on-insulator (SOI) wafer along <110> crystallographic directions that constitute sidewalls ({110} surfaces) suitable for the growth of silicon nanowires in <111> directions with the intention that the gold droplets on the silicon nanowires can meet somewhere in the trench when growth time is carefully selected. Another way to realize gold nanostructures in close vicinity is to attach a silicon nanowire with a gold droplet onto an atomic force microscopy (AFM) tip and to bring this tip toward another gold-coated AFM tip where malachite green molecules were deposited prior to the measurements. In both experiments, signal enhancement of characteristic Raman bands of malachite green molecules was observed. This indicates that silicon nanowires with gold droplets atop can act as efficient probes for tip-enhanced Raman spectroscopy (TERS). In our article, we show that a nanowire TERS probe can be fabricated by welding nanowires with gold droplets to AFM tips in a scanning electron microscope (SEM). TERS tips made from nanowires could improve the spatial resolution of Raman spectroscopy so that measurements on the nanometer scale are possible.

  5. A simple set for ıntrauterine fetal blood transfusion constructed by readily available materials in every clinic.

    PubMed

    Keskin, Uğur; Karasahin, Kazim Emre; Ulubay, Mustafa; Fidan, Ulaş; Gungor, Sadettin; Ergun, Ali

    2015-11-01

    Intrauterine fetal transfusion needs extensive experience and requires excellent eye-hand coordination, good equipment and experienced team workers to achieve success. While the needle is in the umbilical vein, an assistant withdraws and/or transfuses blood. The needle point should be kept still to prevent lacerations and dislodging. We propose a simple set for Intrauterine Fetal blood transfusion is constructed by readily available materials in every clinic to minimize needle tip movement and movements during syringe attachments and withdrawals during the intrauterine fetal transfusion. This makes possible to withdraw fetal blood sample, and to transfuse blood with minimal intervention.

  6. Prediction of destabilizing blade tip forces for shrouded and unshrouded turbines

    NASA Technical Reports Server (NTRS)

    Qiu, Y. J.; Martinezsanchez, M.

    1985-01-01

    The effect of a nonuniform flow field on the Alford force calculation is investigated. The ideas used here are based on those developed by Horlock and Greitzer. It is shown that the nonuniformity of the flow field does contribute to the Alford force calculation. An attempt is also made to include the effect of whirl speed. The values predicted by the model are compared with those obtained experimentally by Urlicks and Wohlrab. The possibility of using existing turbine tip loss correlations to predict beta is also exploited. The nonuniform flow field induced by the tip clearnance variation tends to increase the resultant destabilizing force over and above what would be predicted on the basis of the local variation of efficiency. On the one hand, the pressure force due to the nonuniform inlet and exit pressure also plays a part even for unshrouded blades, and this counteracts the flow field effects, so that the simple Alford prediction remains a reasonable approximation. Once the efficiency variation with clearance is known, the presented model gives a slightly overpredicted, but reasonably accurate destabilizing force. In the absence of efficiency vs. clearance data, an empirical tip loss coefficient can be used to give a reasonable prediction of destabilizing force. To a first approximation, the whirl does have a damping effect, but only of small magnitude, and thus it can be ignored for some purposes.

  7. Factors Predisposing to Maxillary Anchorage Loss: A Retrospective Study of 1403 Cases

    PubMed Central

    Su, Hong; Han, Bing; Li, Sa; Na, Bin; Ma, Wen; Xu, Tian-Min

    2014-01-01

    Anchorage loss is very disturbing for orthodontists and patients during orthodontic treatment, which usually results in bad treatment effects. Despite the same treatment strategy, different patients show different tendencies toward anchorage loss, which influences the treatment results and should preferably be predicted before the treatment is begun. However, relatively little research has been conducted on which patients are more likely to lose anchorage. The mesial tipping of the first molar marks the onset of anchorage loss, and changes in the angulation of the first molar are closely related to anchorage loss. This cross-sectional study aimed to determine how the mesiodistal angulation of the upper first molars changes during general orthodontic treatment and to identify the individual physiologic factors leading to these changes in a large sample of 1403 patients with malocclusion. The data indicate that the upper first molars tend to be tipped mesially during orthodontic treatment, and this constitutes a type of anchorage loss that orthodontists should consider carefully. Compared to treatment-related factors, patients' physiologic characteristics have a greater influence on changes in the angulation of the upper first molars during orthodontic treatment. The more distally tipped the upper first molars are before treatment, the more they will tip mesially during treatment. Mesial tipping of the upper first molars, and therefore, anchorage loss, is more likely to occur in adolescents, males, patients with class II malocclusion and patients who have undergone maxillary premolar extraction. This finding is of clinical significance to orthodontists who wish to prevent iatrogenic anchorage loss by tipping originally distally tipped upper molars forward, and provides a new perspective on anchorage during orthodontic treatment planning. PMID:25299164

  8. Factors predisposing to maxillary anchorage loss: a retrospective study of 1403 cases.

    PubMed

    Su, Hong; Han, Bing; Li, Sa; Na, Bin; Ma, Wen; Xu, Tian-Min

    2014-01-01

    Anchorage loss is very disturbing for orthodontists and patients during orthodontic treatment, which usually results in bad treatment effects. Despite the same treatment strategy, different patients show different tendencies toward anchorage loss, which influences the treatment results and should preferably be predicted before the treatment is begun. However, relatively little research has been conducted on which patients are more likely to lose anchorage. The mesial tipping of the first molar marks the onset of anchorage loss, and changes in the angulation of the first molar are closely related to anchorage loss. This cross-sectional study aimed to determine how the mesiodistal angulation of the upper first molars changes during general orthodontic treatment and to identify the individual physiologic factors leading to these changes in a large sample of 1403 patients with malocclusion. The data indicate that the upper first molars tend to be tipped mesially during orthodontic treatment, and this constitutes a type of anchorage loss that orthodontists should consider carefully. Compared to treatment-related factors, patients' physiologic characteristics have a greater influence on changes in the angulation of the upper first molars during orthodontic treatment. The more distally tipped the upper first molars are before treatment, the more they will tip mesially during treatment. Mesial tipping of the upper first molars, and therefore, anchorage loss, is more likely to occur in adolescents, males, patients with class II malocclusion and patients who have undergone maxillary premolar extraction. This finding is of clinical significance to orthodontists who wish to prevent iatrogenic anchorage loss by tipping originally distally tipped upper molars forward, and provides a new perspective on anchorage during orthodontic treatment planning.

  9. Inpatient Cost Assessment of Transjugular Intrahepatic Portosystemic Shunt in the USA from 2001 to 2012.

    PubMed

    Kuei, Andrew; Lee, Edward Wolfgang; Saab, Sammy; Busuttil, Ronald W; Durazo, Francisco; Han, Steven-Huy; ElKabany, Mohamed; McWilliams, Justin P; Kee, Stephen T

    2016-10-01

    Despite widespread use of transjugular intrahepatic portosystemic shunt (TIPS) for treatment of portal hypertension, a paucity of nationwide data exists on predictors of the economic impact related to TIPS. Using the National Inpatient Sample (NIS) database from 2001 to 2012, we aimed to evaluate factors contributing to hospital cost of patients admitted to US hospitals for TIPS. Using the NIS, we identified a discharge-weighted national estimate of 61,004 TIPS procedures from 2001 to 2012. Through independent sample analysis, we determined profile factors related to increases in hospital costs. Of all TIPS cases, the mean charge adjusted for inflation to the year 2012 is $125,044 ± $160,115. The mean hospital cost adjusted for inflation is $44,901 ± $54,565. Comparing pre- and post-2005, mean charges and cost have increased considerably ($98,154 vs. $142,652, p < 0.001 and $41,656 vs. $46,453, p < 0.001, respectively). Patients transferred from a different hospital, weekend admissions, Asian/Pacific Islander patients, and hospitals in the Northeastern and Western region had higher cost. Number of diagnoses and number of procedures show positive correlations with hospital cost, with number of procedures exhibiting stronger relationships (Pearson 0.613). Comorbidity measures with highest increases in cost were pulmonary circulation disorders ($32,157 increase, p < 0.001). The cost of the TIPS procedure is gradually rising for hospitals. Alongside recent healthcare reform through the Affordable Care Act, measures to reduce the economic burden of TIPS are of increasing importance. Data from this study are intended to aid physicians and hospitals in identifying improvements that could reduce hospital costs.

  10. Preventing Seal Leak During Negative Pressure Wound Therapy Near External Fixators: A Technical Tip.

    PubMed

    Mannino, Brian J; Pullen, Michael W; Gaines, Robert

    2017-03-01

    Negative pressure wound therapy is an effective tool for the treatment of open wounds. Occasionally these wounds are associated with injuries or procedures that require treatment with an external fixator. This article shows how a simple, inexpensive, and commercially available product can be used to prevent loss of suction around external fixator pins within the negative pressure wound treatment area.

  11. Measurement of Air Flow Characteristics Using Seven-Hole Cone Probes

    NASA Technical Reports Server (NTRS)

    Takahashi, Timothy T.

    1997-01-01

    The motivation for this work has been the development of a wake survey system. A seven-hole probe can measure the distribution of static pressure, total pressure, and flow angularity in a wind tunnel environment. The author describes the development of a simple, very efficient algorithm to compute flow properties from probe tip pressures. Its accuracy and applicability to unsteady, turbulent flow are discussed.

  12. Devising, Implementing, and Evaluating Interventions to Eliminate Health Care Disparities in Minority Children

    PubMed Central

    Flores, Glenn

    2010-01-01

    Despite an accumulating body of literature addressing racial/ethnic disparities in children’s health and health care, there have been few published studies of interventions that have been successful in eliminating these disparities. The objectives of this article, therefore, are to (1) describe 3 interventions that have been successful in eliminating racial/ethnic disparities in children’s health and health care, (2) high-light tips and pitfalls regarding devising, implementing, and evaluating pediatric disparities interventions, and (3) propose a research agenda for pediatric disparities interventions. Key characteristics of the 3 successful interventions include rigorous study designs; large sample sizes; appropriate comparison groups; community-based interventions that are culturally and linguistically sensitive and involve collaboration with participants; research staff from the same community as the participants; appropriate blinding of outcomes assessors; and statistical adjustment of outcomes for relevant covariates. On the basis of these characteristics, I propose tips, pitfalls, an approach, and a research agenda for devising, implementing, and evaluating successful pediatric disparities interventions. Examination of 3 successful interventions indicates that pediatric health care disparities can be eliminated. Achievement of this goal requires an intervention that is rigorous, evidence-based, and culturally and linguistically appropriate. The intervention must also include community collaboration, minimize attrition, adjust for potential confounders, and incorporate mechanisms for sustainability. PMID:19861473

  13. Devising, implementing, and evaluating interventions to eliminate health care disparities in minority children.

    PubMed

    Flores, Glenn

    2009-11-01

    Despite an accumulating body of literature addressing racial/ethnic disparities in children's health and health care, there have been few published studies of interventions that have been successful in eliminating these disparities. The objectives of this article, therefore, are to (1) describe 3 interventions that have been successful in eliminating racial/ethnic disparities in children's health and health care, (2) highlight tips and pitfalls regarding devising, implementing, and evaluating pediatric disparities interventions, and (3) propose a research agenda for pediatric disparities interventions. Key characteristics of the 3 successful interventions include rigorous study designs; large sample sizes; appropriate comparison groups; community-based interventions that are culturally and linguistically sensitive and involve collaboration with participants; research staff from the same community as the participants; appropriate blinding of outcomes assessors; and statistical adjustment of outcomes for relevant covariates. On the basis of these characteristics, I propose tips, pitfalls, an approach, and a research agenda for devising, implementing, and evaluating successful pediatric disparities interventions. Examination of 3 successful interventions indicates that pediatric health care disparities can be eliminated. Achievement of this goal requires an intervention that is rigorous, evidence-based, and culturally and linguistically appropriate. The intervention must also include community collaboration, minimize attrition, adjust for potential confounders, and incorporate mechanisms for sustainability.

  14. When Your Parent Has Cancer

    Cancer.gov

    Help for teens whose mom or dad has cancer. Learn how families cope and find support when a parent has cancer. Tips to help you talk with your friends, deal with stress, and take care of your mind and body are also shared.

  15. When Your Brother or Sister Has Cancer

    Cancer.gov

    Help when a brother or sister has cancer. Learn how families cope and find support when a sibling has cancer. Tips to help you talk with your friends, deal with stress, and take care of your mind and body are also shared.

  16. Talking about Complementary and Alternative Medicine with Your Health Care Providers: A Workbook and Tips

    MedlinePlus

    ... therapy Omega-3 fatty acids Osteopathy Probiotics Pulsed electromagnetic fields Qigong Reflexology Reiki Relaxation therapy Selenium Soy ... types of energy therapies are biofield therapies and electromagnetic-based therapies. Biofield therapy: A type of energy ...

  17. The price of palliative care: toward a complete accounting of costs and benefits.

    PubMed

    Boni-Saenz, Alexander A; Dranove, David; Emanuel, Linda L; Lo Sasso, Anthony T

    2005-02-01

    In this article, currently accepted standards for cost-benefit analysis of health care interventions are outlined, and a framework to evaluate palliative care within these standards is provided. Recent publications on the economic implications of palliative care are reviewed, which are only the "tip of the iceberg" of the potential costs and benefits. Using this framework, the authors offer guidelines for performing comprehensive cost-benefit analyses of palliative care and conclude that many of the issues beneath the surface may be substantial and deserving of closer scrutiny. Methods for gathering relevant cost-benefit information are detailed, along with potential obstacles to implementation. This approach is applicable to palliative care in general, including palliative care for elders.

  18. Recovery patterns, histological observations and genetic integrity in Malus shoot tips cryopreserved using droplet-vitrification and encapsulation-dehydration procedures.

    PubMed

    Li, Bai-Quan; Feng, Chao-Hong; Wang, Min-Rui; Hu, Ling-Yun; Volk, Gayle; Wang, Qiao-Chun

    2015-11-20

    A droplet-vitrification procedure is described for cryopreservation of Malus shoot tips. Survival patterns, recovery types, histological observations, and genetic integrity were compared for Malus shoot tips cryopreserved using this droplet-vitrification procedure and an encapsulation-dehydration procedure that was previously reported by us. In both procedures, three types of shoot tip recovery were observed following cryopreservation: callus formation without shoot regrowth, leaf formation without shoot regrowth, and shoot regrowth. Three categories of histological observations were also identified in cross-sections of shoot tips recovered after cryopreservation using the two cryogenic procedures. In category 1, almost all of the cells (94-95%) in the apical dome (AD) were damaged or killed and only some cells (30-32%) in the leaf primordia (LPs) survived. In category 2, only a few cells (18-20%) in the AD and some cells (30-31%) in the LPs survived. In category 3, majority of the cells (60-62%) in the AD and some cells (30-33%) in the LPs survived. These data suggest that shoot regrowth is correlated to the presence of a majority of surviving cells in the AD after liquid nitrogen exposure. No polymorphic bands were detected by inter-simple sequence repeats or by random amplified polymorphic DNA assessments, and ploidy levels analyzed by flow cytometry were unchanged when plants recovered after cryoexposure were compared to controls. The droplet-vitrification procedure appears to be robust since seven genotypes representing four Malus species and one hybrid recovered shoots following cryopreservation. Mean shoot regrowth levels of these seven genotypes were 48% in the droplet-vitrification method, which were lower than those (61%) in the encapsulation-dehydration procedure reported in our previous study, suggesting the latter may be preferred for routine cryobanking applications for Malus shoot tips. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Seismic pattern recognition techniques to predict large eruptions at the Popocatépetl, Mexico, volcano

    NASA Astrophysics Data System (ADS)

    Novelo-Casanova, D. A.; Valdés-González, C.

    2008-10-01

    Using pattern recognition techniques, we formulate a simple prediction rule for a retrospective prediction of the three last largest eruptions of the Popocatépetl, Mexico, volcano that occurred on 23 April-30 June 1997 (Eruption 1; VEI ~ 2-3); 11 December 2000-23 January 2001 (Eruption 2; VEI ~ 3-4) and 7 June-4 September 2002 (Eruption 3; explosive dome extrusion and destruction phase). Times of Increased Probability (TIP) were estimated from the seismicity recorded by the local seismic network from 1 January 1995 to 31 December 2005. A TIP is issued when a cluster of seismic events occurs under our algorithm considerations in a temporal window several days (or weeks) prior to large volcanic activity providing sufficient time to organize an effective alert strategy. The best predictions of the three analyzed eruptions were obtained when averaging seismicity rate over a 5-day window with a threshold value of 12 events and declaring an alarm for 45 days. A TIP was issued about six weeks before Eruption 1. TIPs were detected about one and four weeks before Eruptions 2 and 3, respectively. According to our objectives, in all cases, the observed TIPs would have allowed the development of an effective civil protection strategy. Although, under our model considerations the three eruptive events were successfully predicted, one false alarm was also issued by our algorithm. An analysis of the epicentral and depth distribution of the local seismicity used by our prediction rule reveals that successful TIPs were issued from microearthquakes that took place below and towards SE of the crater. On the contrary, the seismicity that issued the observed false alarm was concentrated below the summit of the volcano. We conclude that recording of precursory seismicity below and SE of the crater together with detection of TIPs as described here, could become an important tool to predict future large eruptions at Popocatépetl. Although our model worked well for events that occurred in the past, it is necessary to verify the real capability of the model for future eruptive events.

  20. Trials of Improved Practices (TIPs) to Enhance the Dietary and Iron-Folate Intake during Pregnancy- A Quasi Experimental Study among Rural Pregnant Women of Varanasi, India

    PubMed Central

    Shivalli, Siddharudha; Srivastava, Ratan Kumar; Singh, Gyan Prakash

    2015-01-01

    Background Behavior Change Communications (BCC) play a decisive role in modifying socio-cultural norms affecting the perception and nutritional practices during pregnancy. Objective To examine the effectiveness of ‘Trials of Improved Practices’ (TIPs) on dietary and iron-folate intake during pregnancy. Design Community based quasi experimental study with a control group Setting Four villages of Chiraigaon Community Development Block of Varanasi, India from May 2010 and recruited from August 2010. End line assessment, after 12 weeks of intervention, was completed in April 2011. Participants Pregnant women in 13–28 weeks of gestation Intervention TIPs was implemented in addition to ongoing essential obstetric care services in two villages through 3 home (assessment, negotiation and evaluation) visits and only assessment and evaluation visits in the other two control villages. Interpersonal communication, endorsing the active participation of family members and home based reminder materials were the TIPs based strategies. The effect of TIPs was assessed by comparing key outcome variables at baseline and after 12 weeks of intervention. Outcome Measures Hemoglobin%, anemia prevalence, weight gain, compliance for iron-folate supplementation and dietary intake of calorie, protein, calcium and iron. Results A total of 86 participants completed the study. At the end, mean hemoglobin levels were 11.5±1.24 g/dl and 10.37±1.38 g/dl in the TIPs and control groups, respectively. The prevalence of anemia reduced by half in TIPs group and increased by 2.4% in the control group. Weight gain (grams/week) was significantly (p<0.01) higher in TIPs group (326.9±91.8 vs. 244.6±97.4). More than 85% of the PW in TIPs group were compliant for Iron-folate and only 38% were compliant among controls. The mean intake of protein increased by 1.78gm in intervention group and decreased by 1.81 gm in controls (p<0.05). More than two thirds of PW in TIPs group were taking one extra meal and only one third of controls were doing the same. Conclusion TIPs found to be an effective approach to improve the nutritional status of pregnant women in the study area. TIPs strategy could be further explored on larger sample representing different socio-cultural and geographical areas. Trial Registration Clinical Trial Registry of India CTRI/2015/02/005517 PMID:26367775

  1. The application of an atomistic J-integral to a ductile crack.

    PubMed

    Zimmerman, Jonathan A; Jones, Reese E

    2013-04-17

    In this work we apply a Lagrangian kernel-based estimator of continuum fields to atomic data to estimate the J-integral for the emission dislocations from a crack tip. Face-centered cubic (fcc) gold and body-centered cubic (bcc) iron modeled with embedded atom method (EAM) potentials are used as example systems. The results of a single crack with a K-loading compare well to an analytical solution from anisotropic linear elastic fracture mechanics. We also discovered that in the post-emission of dislocations from the crack tip there is a loop size-dependent contribution to the J-integral. For a system with a finite width crack loaded in simple tension, the finite size effects for the systems that were feasible to compute prevented precise agreement with theory. However, our results indicate that there is a trend towards convergence.

  2. Design and development of flapping wing micro air vehicle

    NASA Astrophysics Data System (ADS)

    Hynes, N. Rajesh Jesudoss; Solomon, A. Jeffey Markus; Kathiresh, E.; Brighton, D.; Velu, P. Shenbaga

    2018-05-01

    Birds and insects have different methods of producing lift and thrust for hovering and forward flight. Most birds, however, cannot hover. Wing tips of birds follow simple paths in flight, whereas insects have very complicated wing tip paths, for hovering and forward flight, which vary with each species. FMAV based on avian flight. Development of Flapping Wing Air Vehicle (FWAV) is an on-going quest to master the natural flyers by mechanical means. It is characterized by unsteady aerodynamics, whose knowledge is still developing. The present work aims at include being capable of manoeuvring around and over obstacles by adjusting pitch, yaw, and roll, able to glide for five seconds under its own power, skilful at alternating between flapping and gliding with minimal disruption of flight pattern and being durable enough to withstand impacts with minimal to no damage.

  3. Engine spectrometer probe and method of use

    NASA Technical Reports Server (NTRS)

    Barkhoudarian, Sarkis (Inventor); Kittinger, Scott A. (Inventor)

    2006-01-01

    The engine spectrometer probe and method of using the same of the present invention provides a simple engine spectrometer probe which is both lightweight and rugged, allowing an exhaust plume monitoring system to be attached to a vehicle, such as the space shuttle. The engine spectrometer probe can be mounted to limit exposure to the heat and debris of the exhaust plume. The spectrometer probe 50 comprises a housing 52 having an aperture 55 and a fiber optic cable 60 having a fiber optic tip 65. The fiber optic tip 65 has an acceptance angle 87 and is coupled to the aperture 55 so that the acceptance angle 87 intersects the exhaust plume 30. The spectrometer probe can generate a spectrum signal from light in the acceptance angle 506 and the spectrum signal can be provided to a spectrometer 508.

  4. Separating the Influence of Environment from Stress Relaxation Effects on Dwell Fatigue Crack Growth

    NASA Technical Reports Server (NTRS)

    Telesman, Jack; Gabb, Tim; Ghosn, Louis J.

    2016-01-01

    Seven different microstructural variations of LSHR were produced by controlling the cooling rate and the subsequent aging and thermal exposure heat treatments. Through cyclic fatigue crack growth testing performed both in air and vacuum, it was established that four out of the seven LSHR heat treatments evaluated, possessed similar intrinsic environmental resistance to cyclic crack growth. For these four heat treatments, it was further shown that the large differences in dwell crack growth behavior which still persisted, were related to their measured stress relaxation behavior. The apparent differences in their dwell crack growth resistance were attributed to the inability of the standard linear elastic fracture mechanics (LEFM) stress intensity parameter to account for visco-plastic behavior. Crack tip stress relaxation controls the magnitude of the remaining local tensile stresses which are directly related to the measured dwell crack growth rates. It was hypothesized that the environmentally weakened grain boundary crack tip regions fail during the dwells when their strength is exceeded by the remaining local crack tip tensile stresses. It was shown that the classical creep crack growth mechanisms such as grain boundary sliding did not contribute to crack growth, but the local visco-plastic behavior still plays a very significant role by determining the crack tip tensile stress field which controls the dwell crack growth behavior. To account for the influence of the visco-plastic behavior on the crack tip stress field, an empirical modification to the LEFM stress intensity parameter, Kmax, was developed by incorporating into the formulation the remaining stress level concept as measured by simple stress relaxation tests. The newly proposed parameter, Ksrf, did an excellent job in correlating the dwell crack growth rates for the four heat treatments which were shown to have similar intrinsic environmental cyclic fatigue crack growth resistance.

  5. Nano-cone optical fiber array sensors for MiRNA profiling

    NASA Astrophysics Data System (ADS)

    Wang, Yunshan; Senapati, Satyajyoti; Stoddart, Paul; Howard, Scott; Chang, Hsueh-Chia

    2013-09-01

    Up/down regulation of microRNA panels has been correlated to cardiovascular diseases and cancer. Frequent miRNA profiling at home can hence allow early cancer diagnosis and home-use chronic disease monitoring, thus reducing both mortality rate and healthcare cost. However, lifetime of miRNAs is less than 1 hour without preservation and their concentrations range from pM to mM. Despite rapid progress in the last decade, modern nucleic acid analysis methods still do not allow personalized miRNA profiling---Real-time PCR and DNA micro-array both require elaborate miRNA preservation steps and expensive equipment and nano pore sensors cannot selectively quantify a large panel with a large dynamic range. We report a novel and low-cost optical fiber sensing platform, which has the potential to profile a panel of miRNA with simple LED light sources and detectors. The individual tips of an optical imaging fiber bundle (mm in diameter with 7000 fiber cores) were etched into cones with 10 nm radius of curvature and coated with Au. FRET (Forster Resonant Energy Transfer) hairpin oligo probes, with the loop complementary to a specific miRNA that can release the hairpin, were functionalized onto the conic tips. Exciting light in the optical fiber waveguide is optimally coupled to surface plasmonics on the gold surface, which then converges to the conic tips with two orders of magnitude enhancement in intensity. Unlike nanoparticle plasmonics, tip plasmonics can be excited over a large band width and hence the plasmonic enhanced fluorescence signal of the FRET reporter is also focused towards the tip--- and is further enhanced with the periodic resonant grid of the fiber array which gives rise to pronounced standing wave interference patterns. Multiplexing is realized by functionalizing different probes onto one fiber bundle using a photoactivation process.

  6. Solid surface wetting and the deployment of drops in microgravity

    NASA Technical Reports Server (NTRS)

    Trinh, E. H.; Depew, J.

    1994-01-01

    The complete or partial deployment of liquid samples in low gravity is primarily influenced by the interfacial properties of the specific liquid and solid materials used because the overwhelming bias of the Earth gravitational acceleration is removed. This study addresses the engineering aspects of injecting and deploying drops of prescribed volume into an acoustic positioning chamber in microgravity. The specific problems of interest are the design, testing, and implementation of injector tips to be used in a simultaneously retracting dual-injector system in the Drop Physics Module microgravity experiment facility. Prior to release, the liquid to be deployed must be retained within a restricted area at the very end of the injectors under dynamic stimuli from the continuous injection flow as well as from the stepped motion of the injectors. The final released drop must have a well determined volume and negligible residual linear or angular momentum. The outcome of Earth-based short-duration low gravity experiments had been the selection of two types of injector tips which were flown as back-up parts. They were successfully utilized during the USML-1 Spacelab mission as the primary tips. The combination of a larger contact surface, liquid pinning with a sharp edge, and selective coating of strategic tip surfaces with a non-wetting compound has allowed a significant increase in the success rate of deployment of simple and compound drops of aqueous solutions of glycerol and silicone oil. The diameter of the samples studied in the Drop Physics Module range between 0.3 and 2.7 cm. The tests conducted on-orbit with a manually operated small device have allowed the calibration of the volume deployed for a few drop sizes. The design for improved tips to be used during the next USML flight is based on these results.

  7. Tapered fiber optic applicator for laser ablation: Theoretical and experimental assessment of thermal effects on ex vivo model.

    PubMed

    Saccomandi, P; Di Matteo, F M; Schena, E; Quero, G; Massaroni, C; Giurazza, F; Costamagna, G; Silvestri, S

    2017-07-01

    Laser Ablation (LA) is a minimally invasive technique for tumor removal. The laser light is guided into the target tissue by a fiber optic applicator; thus the physical features of the applicator tip strongly influence size and shape of the tissue lesion. This study aims to verify the geometry of the lesion achieved by a tapered-tip applicator, and to investigate the percentage of thermally damaged cells induced by the tapered-tip fiber optic applicator. A theoretical model was implemented to simulate: i) the distribution of laser light fluence rate in the tissue through Monte Carlo method, ii) the induced temperature distribution, by means of the Bio Heat Equation, iii) the tissue injury, by Arrhenius integral. The results obtained by the implementation of the theoretical model were experimentally assessed. Ex vivo porcine liver underwent LA with tapered-tip applicator, at different laser settings (laser power of 1 W and 1.7 W, deposited energy equal to 330 J and 500 J, respectively). Almost spherical volume lesions were produced. The thermal damage was assessed by measuring the diameter of the circular-shaped lesion. The comparison between experimental results and theoretical prediction shows that the thermal damage discriminated by visual inspection always corresponds to a percentage of damaged cells of 96%. A tapered-tip applicator allows obtaining localized and reproducible damage close to spherical shape, whose diameter is related to the laser settings, and the simple theoretical model described is suitable to predict the effects, in terms of thermal damage, on ex vivo liver. Further trials should be addressed to adapt the model also on in vivo tissue, aiming to develop a tool useful to support the physician in clinical application of LA.

  8. Ten Tips To Aid Teachers Creating Multimedia Presentations.

    ERIC Educational Resources Information Center

    Ennis, Willie; Ennis, Demetria

    1996-01-01

    Suggestions to help teachers create original multimedia presentations and lessons include building resource teams, knowing intellectual property and copyright issues, analyzing target audiences, carefully selecting media, considering hardware and software requirements, seeking technical support, encouraging distribution on the World Wide Web,…

  9. Tips on Training.

    ERIC Educational Resources Information Center

    DePutte, Toni Van, Ed.; And Others

    The articles in this collection are addressed to athletic coaches or ancillary health personnel practitioners who treat athletes' injuries. Emphasis is upon proper immediate care, recognition and referral of serious injuries, and preventive measures to reduce injuries. Papers include: (1) "Planning a High School Athletic Training Program" (Stanley…

  10. A Simple Method for Closure of Urethrocutaneous Fistula after Tubularized Incised Plate Repair: Preliminary Results.

    PubMed

    Shirazi, Mehdi; Ariafar, Ali; Babaei, Amir Hossein; Ashrafzadeh, Abdosamad; Adib, Ali

    2016-11-01

    Urethrocutaneous fistula (UCF) is the most prevalent complication after hypospadias repair surgery. Many methods have been developed for UCF correction, and the best technique for UCF repair is determined based on the size, location, and number of fistulas, as well as the status of the surrounding skin. In this study, we introduced and evaluated a simple method for UCF correction after tubularized incised plate (TIP) repair. This clinical study was conducted on children with UCFs ≤ 4 mm that developed after TIP surgery for hypospadias repair. The skin was incised around the fistula and the tract was released from the surrounding tissues and the dartos fascia, then ligated with 5 - 0 polydioxanone (PDS) sutures. The dartos fascia, as the second layer, was covered on the fistula tract with PDS thread (gauge 5 - 0) by the continuous suture method. The skin was closed with 6 - 0 Vicryl sutures. After six months of follow-up, surgical outcomes were evaluated based on fistula relapse and other complications. After six months, relapse occurred in only one patient, a six-year-old boy with a single 4-mm distal opening, who had undergone no previous fistula repairs. Therefore, in 97.5% of the cases, relapse was non-existent. Other complications, such as urethral stenosis, intraurethral obstruction, and epidermal inclusion cysts, were not seen in the other patients during the six-month follow-up period. This repair method, which is simple, rapid, and easily learned, is highly applicable, with a high success rate for the closure of UCFs measuring up to 4 mm in any location.

  11. Safe surgical technique for associated acetabular fractures

    PubMed Central

    2013-01-01

    Associated acetabular fractures are challenging injuries to manage. The complex surgical approaches and the technical difficulty in achieving anatomical reduction imply that the learning curve to achieve high-quality care of patients with such challenging injuries is extremely steep. This first article in the Journal’s “Safe Surgical Technique” section presents the standard surgical care, in conjunction with intraoperative tips and tricks, for the safe management of all subgroups of associated acetabular fractures. PMID:23414782

  12. Bio-inspired Composites, a de novo Approach to the Conceptualization, Design and Synthesis of Tough Mesoscale Structures with Simple Building Blocks

    DTIC Science & Technology

    2013-02-01

    41   4.4.1   Ordered arrangement of nanoporous silica – Decreasing sensitivity to cracks 44...materials become insensitive to flaws, thus enabling them to reach their theoretical strength irrespective of cracks or defects. Furthermore, in...highlighting the essential role of large stiffness-ratios in reducing crack tip stress concentrations in lamellar structures [32, 33]. Furthermore, a

  13. Standardized methods for photography in procedural dermatology using simple equipment.

    PubMed

    Hexsel, Doris; Hexsel, Camile L; Dal'Forno, Taciana; Schilling de Souza, Juliana; Silva, Aline F; Siega, Carolina

    2017-04-01

    Photography is an important tool in dermatology. Reproducing the settings of before photos after interventions allows more accurate evaluation of treatment outcomes. In this article, we describe standardized methods and tips to obtain photographs, both for clinical practice and research procedural dermatology, using common equipment. Standards for the studio, cameras, photographer, patients, and framing are presented in this article. © 2017 The International Society of Dermatology.

  14. The role of self-regulatory skills and automaticity on the effectiveness of a brief weight loss habit-based intervention: secondary analysis of the 10 top tips randomised trial.

    PubMed

    Kliemann, Nathalie; Vickerstaff, Victoria; Croker, Helen; Johnson, Fiona; Nazareth, Irwin; Beeken, Rebecca J

    2017-09-05

    Habit-interventions are designed to promote the automaticity of healthy behaviours and may also enhance self-regulatory skills during the habit-formation process. A recent trial of habit-based advice for weight loss (10 Top Tips; 10TT), found that patients allocated to 10TT lost significantly more weight over 3 months than those allocated to usual care, and reported greater increases in automaticity for the target behaviours. The current study aimed to test the hypothesis that i) 10TT increased self-regulatory skills more than usual care, and ii) that self-regulatory skills and automaticity changes mediated the effect of 10TT on weight loss. 537 obese patients from 14 primary care practices in the UK were randomized to receive 10TT or usual care. Patients in the 10TT group received a leaflet containing tips for weight loss and healthy habits formation, a self-monitoring log book and a wallet-sized shopping guide on how to read food labels. Patients were weighed and completed validated questionnaires for self-regulation and automaticity at baseline and 3-month follow-up. Within-group and Between-group effects were explored using Paired T-test and ANCOVA, respectively. Mediation was assessed using bootstrapping to estimate indirect effects and the sobel test. Over 3 months patients who were given 10TT reported greater increases in self-regulatory skills (Mean difference: .08; 95% CI .01; .15) than those who received usual care. Changes in self-regulatory skills and automaticity over 3 months mediated the effect of the intervention on weight loss (β = .52, 95% Bias Corrected CI .17; .91). As hypothesised, 10TT enhanced self-regulatory skills and changes in self-regulatory skills and automaticity mediated the effect of the intervention on weight loss. This supports the proposition that self-regulatory training and habit formation are important features of weight loss interventions. This study was prospectively registered with the International Standard Randomised Controlled Trials ( ISRCTN16347068 ) on 26 September 2011.

  15. Twelve tips for delivering successful interprofessional case conferences.

    PubMed

    O'Brien, Bridget C; Patel, Shalini R; Pearson, Meg; Eastburn, Abigail P; Earnest, Gillian E; Strewler, Anna; Gager, Krista; Manuel, Jennifer K; Dulay, Maya; Bachhuber, Melissa R; Shunk, Rebecca

    2017-12-01

    Interprofessional case conferences (ICCs) offer an interactive, practical way to engage members of two or more health professions in discussions that involve learning and working together to improve patient care. Well-orchestrated ICCs provide opportunities to integrate interprofessional (IP) education into routine clinical practice. The authors provide 12 tips to support the conceptualization, planning, implementation, facilitation, evaluation, and sustainability of ICCs. They draw from extensive experience as IP educators and facilitators of ICCs and from literature on IP education, case-based learning, small-group facilitation, peer-assisted learning, and learner engagement - all of which offer insights into ICCs but have not been integrated and applied to this context.

  16. Digital chat reference in health science libraries: challenges in initiating a new service.

    PubMed

    Dee, Cheryl R; Newhouse, Joshua D

    2005-01-01

    Digital reference service adds a valuable new dimension to health science reference services, but the road to implementation can present questions that require carefully considered decisions. This article incorporates suggestions from the published literature, provides tips from interviews with practicing academic health science librarians, and reports on data from students' exploration of academic health science library Web sites' digital reference services. The goal of this study is to provide guidelines to plan new services, assess user needs, and select software, and to showcase potential benefits of collaboration and proactive and user-friendly marketing. In addition, tips for successful operation and evaluation of services are discussed.

  17. A Model Rotor in Axial Flight

    NASA Technical Reports Server (NTRS)

    McAlister, K. W.; Huang, S. S.; Abrego, A. I.

    2001-01-01

    A model rotor was mounted horizontally in the settling chamber of a wind tunnel to obtain performance and wake structure data under low climb conditions. The immediate wake of the rotor was carefully surveyed using 3-component particle image velocimetry to define the velocity and vortical content of the flow, and used in a subsequent study to validate a theory for the separate determination of induced and profile drag. Measurements were obtained for two collective pitch angles intended to render a predominately induced drag state and another with a marked increase in profile drag. A majority of the azimuthally directed vorticity in the wake was found to be concentrated in the tip vortices. However, adjacent layers of inboard vorticity with opposite sense were clearly present. At low collective, the close proximity of the tip vortex from the previous blade caused the wake from the most recent blade passage to be distorted. The deficit velocity component that was directed along the azimuth of the rotor blade was never more that 15 percent of the rotor tip speed, and except for the region of the tip vortex, appeared to have totally disappeared form the wake left by the previous blade.

  18. Tailored Prevention of Inpatient Falls

    PubMed Central

    ZUYEV, LYUBOV; BENOIT, ANGELA N.; CHANG, FRANK Y.; DYKES, PATRICIA C.

    2011-01-01

    Patient falls and fall-related injuries are serious problems in hospitals. The Fall TIPS application aims to prevent patient falls by translating routine nursing fall risk assessment into a decision support intervention that communicates fall risk status and creates a tailored evidence-based plan of care that is accessible to the care team, patients, and family members. In our design and implementation of the Fall TIPS toolkit, we used the Spiral Software Development Life Cycle model. Three output tools available to be generated from the toolkit are bed poster, plan of care, and patient education handout. A preliminary design of the application was based on initial requirements defined by project leaders and informed by focus groups with end users. Preliminary design partially simulated the paper version of the Morse Fall Scale currently used in hospitals involved in the research study. Strengths and weaknesses of the first prototype were identified by heuristic evaluation. Usability testing was performed at sites where research study is implemented. Suggestions mentioned by end users participating in usability studies were either directly incorporated into the toolkit and output tools, were slightly modified, or will be addressed during training. The next step is implementation of the fall prevention toolkit on the pilot testing units. PMID:20975543

  19. Accurate formulas for interaction force and energy in frequency modulation force spectroscopy

    NASA Astrophysics Data System (ADS)

    Sader, John E.; Jarvis, Suzanne P.

    2004-03-01

    Frequency modulation atomic force microscopy utilizes the change in resonant frequency of a cantilever to detect variations in the interaction force between cantilever tip and sample. While a simple relation exists enabling the frequency shift to be determined for a given force law, the required complementary inverse relation does not exist for arbitrary oscillation amplitudes of the cantilever. In this letter we address this problem and present simple yet accurate formulas that enable the interaction force and energy to be determined directly from the measured frequency shift. These formulas are valid for any oscillation amplitude and interaction force, and are therefore of widespread applicability in frequency modulation dynamic force spectroscopy.

  20. Simulation of fatigue crack growth under large scale yielding conditions

    NASA Astrophysics Data System (ADS)

    Schweizer, Christoph; Seifert, Thomas; Riedel, Hermann

    2010-07-01

    A simple mechanism based model for fatigue crack growth assumes a linear correlation between the cyclic crack-tip opening displacement (ΔCTOD) and the crack growth increment (da/dN). The objective of this work is to compare analytical estimates of ΔCTOD with results of numerical calculations under large scale yielding conditions and to verify the physical basis of the model by comparing the predicted and the measured evolution of the crack length in a 10%-chromium-steel. The material is described by a rate independent cyclic plasticity model with power-law hardening and Masing behavior. During the tension-going part of the cycle, nodes at the crack-tip are released such that the crack growth increment corresponds approximately to the crack-tip opening. The finite element analysis performed in ABAQUS is continued for so many cycles until a stabilized value of ΔCTOD is reached. The analytical model contains an interpolation formula for the J-integral, which is generalized to account for cyclic loading and crack closure. Both simulated and estimated ΔCTOD are reasonably consistent. The predicted crack length evolution is found to be in good agreement with the behavior of microcracks observed in a 10%-chromium steel.

  1. Carbon Nanotube Tip Probes: Stability and Lateral Resolution in Scanning Probe Microscopy and Application to Surface Science to Semiconductors

    NASA Technical Reports Server (NTRS)

    Nguyen, Cattien V.; Chao, Kuo-Jen; Stevens, Ramsey M. D.; Delzeit, Lance; Cassell, Alan; Han, Jie; Meyyappan, M.; Arnold, James (Technical Monitor)

    2001-01-01

    In this paper we present results on the stability and lateral resolution capability of carbon nanotube (CNT) scanning probes as applied to atomic force microscopy (AFM). Surface topography images of ultra-thin films (2-5 nm thickness) obtained with AFM are used to illustrate the lateral resolution capability of single-walled carbon nanotube probes. Images of metal films prepared by ion beam sputtering exhibit grain sizes ranging from greater than 10 nm to as small as approximately 2 nm for gold and iridium respectively. In addition, imaging stability and lifetime of multi-walled carbon nanotube scanning probes are studied on a relatively hard surface of silicon nitride (Si3N4). AFM images Of Si3N4 surface collected after more than 15 hrs of continuous scanning show no detectable degradation in lateral resolution. These results indicate the general feasibility of CNT tips and scanning probe microscopy for examining nanometer-scale surface features of deposited metals as well as non-conductive thin films. AFM coupled with CNT tips offers a simple and nondestructive technique for probing a variety of surfaces, and has immense potential as a surface characterization tool in integrated circuit manufacturing.

  2. Ten tips for authors of scientific articles.

    PubMed

    Hong, Sung-Tae

    2014-08-01

    Writing a good quality scientific article takes experience and skill. I propose 'Ten Tips' that may help to improve the quality of manuscripts for scholarly journals. It is advisable to draft first version of manuscript and revise it repeatedly for consistency and accuracy of the writing. During the drafting and revising the following tips can be considered: 1) focus on design to have proper content, conclusion, points compliant with scope of the target journal, appropriate authors and contributors list, and relevant references from widely visible sources; 2) format the manuscript in accordance with instructions to authors of the target journal; 3) ensure consistency and logical flow of ideas and scientific facts; 4) provide scientific confidence; 5) make your story interesting for your readers; 6) write up short, simple and attractive sentences; 7) bear in mind that properly composed and reflective titles increase chances of attracting more readers; 8) do not forget that well-structured and readable abstracts improve citability of your publications; 9) when revising adhere to the rule of 'First and Last' - open your text with topic paragraph and close it with resolution paragraph; 10) use connecting words linking sentences within a paragraph by repeating relevant keywords.

  3. Ten Tips for Authors of Scientific Articles

    PubMed Central

    2014-01-01

    Writing a good quality scientific article takes experience and skill. I propose 'Ten Tips' that may help to improve the quality of manuscripts for scholarly journals. It is advisable to draft first version of manuscript and revise it repeatedly for consistency and accuracy of the writing. During the drafting and revising the following tips can be considered: 1) focus on design to have proper content, conclusion, points compliant with scope of the target journal, appropriate authors and contributors list, and relevant references from widely visible sources; 2) format the manuscript in accordance with instructions to authors of the target journal; 3) ensure consistency and logical flow of ideas and scientific facts; 4) provide scientific confidence; 5) make your story interesting for your readers; 6) write up short, simple and attractive sentences; 7) bear in mind that properly composed and reflective titles increase chances of attracting more readers; 8) do not forget that well-structured and readable abstracts improve citability of your publications; 9) when revising adhere to the rule of 'First and Last' - open your text with topic paragraph and close it with resolution paragraph; 10) use connecting words linking sentences within a paragraph by repeating relevant keywords. PMID:25120310

  4. Non-contact lateral force microscopy.

    PubMed

    Weymouth, A J

    2017-08-16

    The goal of atomic force microscopy (AFM) is to measure the short-range forces that act between the tip and the surface. The signal recorded, however, includes long-range forces that are often an unwanted background. Lateral force microscopy (LFM) is a branch of AFM in which a component of force perpendicular to the surface normal is measured. If we consider the interaction between tip and sample in terms of forces, which have both direction and magnitude, then we can make a very simple yet profound observation: over a flat surface, long-range forces that do not yield topographic contrast have no lateral component. Short-range interactions, on the other hand, do. Although contact-mode is the most common LFM technique, true non-contact AFM techniques can be applied to perform LFM without the tip depressing upon the sample. Non-contact lateral force microscopy (nc-LFM) is therefore ideal to study short-range forces of interest. One of the first applications of nc-LFM was the study of non-contact friction. A similar setup is used in magnetic resonance force microscopy to detect spin flipping. More recently, nc-LFM has been used as a true microscopy technique to systems unsuitable for normal force microscopy.

  5. On the Connection Between Flap Side-Edge Noise and Tip Vortex Dynamics

    NASA Technical Reports Server (NTRS)

    Casalino, D.; Hazir, A.; Fares, E.; Duda, B.; Khorrami, M. R.

    2015-01-01

    The goal of the present work is to investigate how the dynamics of the vortical flow about the flap side edge of an aircraft determine the acoustic radiation. A validated lattice- Boltzmann CFD solution of the unsteady flow about a detailed business jet configuration in approach conditions is used for the present analysis. Evidence of the connection between the noise generated by several segments of the inboard flap tip and the aerodynamic forces acting on the same segments is given, proving that the noise generation mechanism has a spatially coherent and acoustically compact character on the scale of the flap chord, and that the edge-scattering effects are of secondary importance. Subsequently, evidence of the connection between the kinematics of the tip vortex system and the aerodynamic force is provided. The kinematics of the dual vortex system are investigated via a core detection technique. Emphasis is placed on the mutual induction effects between the two main vortices rolling up from the pressure and suction sides of the flap edge. A simple heuristic formula that relates the far-field noise spectrum and the cross-spectrum of the unsteady vortical positions is developed.

  6. Local flow measurements at the inlet spike tip of a Mach 3 supersonic cruise airplane

    NASA Technical Reports Server (NTRS)

    Johnson, H. J.; Montoya, E. J.

    1973-01-01

    The flow field at the left inlet spike tip of a YF-12A airplane was examined using at 26 deg included angle conical flow sensor to obtain measurements at free-stream Mach numbers from 1.6 to 3.0. Local flow angularity, Mach number, impact pressure, and mass flow were determined and compared with free-stream values. Local flow changes occurred at the same time as free-stream changes. The local flow usually approached the spike centerline from the upper outboard side because of spike cant and toe-in. Free-stream Mach number influenced the local flow angularity; as Mach number increased above 2.2, local angle of attack increased and local sideslip angle decreased. Local Mach number was generally 3 percent less than free-stream Mach number. Impact-pressure ratio and mass flow ratio increased as free-stream Mach number increased above 2.2, indicating a beneficial forebody compression effect. No degradation of the spike tip instrumentation was observed after more than 40 flights in the high-speed thermal environment encountered by the airplane. The sensor is rugged, simple, and sensitive to small flow changes. It can provide accurate imputs necessary to control an inlet.

  7. Coping with Chronic Illness

    MedlinePlus

    ... you develop strategies to regain a feeling of control. Support groups might help, too. You will find that you are not alone, and you may learn some new tips on how to cope. You may ... It is also important to find a health care provider that you can trust.

  8. Hard Facts.

    ERIC Educational Resources Information Center

    Shaw, Richard

    1998-01-01

    Discusses the selection of floor-care equipment so that the equipment's features and performance attributes can match their intended purposes. Offers tips such as buying only composite-material buckets and wringers, choosing cleaning machines with good maintenance track records, and buying automatic scrubbers that can operate in both large and…

  9. Obstacles to care in first-episode psychosis patients with a long duration of untreated psychosis.

    PubMed

    Bay, Nina; Bjørnestad, Jone; Johannessen, Jan O; Larsen, Tor K; Joa, Inge

    2016-02-01

    This qualitative study is a sub-study of the early 'Treatment and Intervention in Psychosis Study' (TIPS-2), a program for early intervention strategies for people experiencing a first episode of psychosis. We aimed to improve knowledge about factors that prevent or delay patients with a long duration of psychosis from accessing psychiatric health-care services at an earlier illness stage and their personal views on the impact of ongoing informational campaigns (ICs) on help-seeking behaviour. Following an interpretative-phenomenological approach, eight consecutive TIPS-2 patients with duration of untreated psychosis lasting for more than 6 months were interviewed. The interviews were analysed using a meaning condensation procedure. Five main themes were identified: (i) participants' failure to recognize symptoms of psychosis; (ii) difficulties expressing their experiences; (iii) concerns about stigma; (iv) poor psychosis detection skills among health-care professionals; and (v) participants' lack of awareness or understanding of ICs. The five themes identified may suggest that despite exposure to the targeted ICs, participants were unable to recognize or understand the severity of their symptoms. Further, although family members or others sometimes recognized the initial symptoms of psychosis development, these symptoms were attributed to reasons other than psychosis. Participants reported that health-care personnel also had trouble identifying emerging signs of psychosis. The ICs need to be carefully crafted to relay information to people who do not consider themselves as currently experiencing signs of psychosis. © 2014 Wiley Publishing Asia Pty Ltd.

  10. A therapist-focused knowledge translation intervention for improving patient adherence in musculoskeletal physiotherapy practice.

    PubMed

    Babatunde, Folarin Omoniyi; MacDermid, Joy Christine; MacIntyre, Norma

    2017-01-01

    Nonadherence to treatment remains high among patients with musculoskeletal conditions with negative impact on the treatment outcomes, use of personal and cost of care. An active knowledge translation (KT) strategy may be an effective strategy to support practice change. The purpose of this study was to deliver a brief, interactive, multifaceted and targeted KT program to improve physiotherapist knowledge and confidence in performing adherence enhancing activities related to risk, barriers, assessment and interventions. We utilised a 2-phase approach in this KT project. Phase 1 involved the development of an adherence tool kit following a synthesis of the literature and an iterative process involving 47 end-users. Clinicians treating patients with musculoskeletal conditions were recruited from two Physiotherapy and Occupational therapy national conferences in Canada. The intervention, based on the acronym SIMPLE TIPS was tested on 51 physiotherapists in phase 2. A pre- and post-repeated measures design was used in Phase 2. Graham's knowledge-to-action cycle was used as the conceptual framework. Participants completed a pre-intervention assessment, took part in a 1-h educational session and completed a post-intervention assessment. A questionnaire was used to measure knowledge of evidence-based treatment adherence barriers, interventions and measures and confidence to perform evidence-based adherence practice activities. Data was analysed using descriptive statistics (frequency and percentage), Fisher's exact test and Wilcoxon Sign-Ranked tests. Barriers and facilitators of adherence were identified under three domains (therapist, patient, health system) in phase 1. Seventy percent of the participants completed the questionnaire. Results indicated that 46.8% of respondents explored barriers including the use of behaviour change strategies and 45.7% reported that they measured adherence but none reported the use of validated outcomes. A significant improvement in post-self-efficacy scores for the four adherence enhancing activities was observed immediately after the workshop. The use of a multi-modal KT intervention is feasible in an educational setting. A brief interactive educational session was successfully implemented using a toolkit and caused a significant increase in physiotherapists' knowledge and confidence at performing adherence enhancing activities in the very short-term. Further testing of SIMPLE TIPS on long-term adherence practices could help advance best practices specific to treatment adherence in MSK practice.

  11. The Spatial Distribution of the Exocyst and Actin Cortical Patches Is Sufficient To Organize Hyphal Tip Growth

    PubMed Central

    Caballero-Lima, David; Kaneva, Iliyana N.; Watton, Simon P.

    2013-01-01

    In the hyphal tip of Candida albicans we have made detailed quantitative measurements of (i) exocyst components, (ii) Rho1, the regulatory subunit of (1,3)-β-glucan synthase, (iii) Rom2, the specialized guanine-nucleotide exchange factor (GEF) of Rho1, and (iv) actin cortical patches, the sites of endocytosis. We use the resulting data to construct and test a quantitative 3-dimensional model of fungal hyphal growth based on the proposition that vesicles fuse with the hyphal tip at a rate determined by the local density of exocyst components. Enzymes such as (1,3)-β-glucan synthase thus embedded in the plasma membrane continue to synthesize the cell wall until they are removed by endocytosis. The model successfully predicts the shape and dimensions of the hyphae, provided that endocytosis acts to remove cell wall-synthesizing enzymes at the subapical bands of actin patches. Moreover, a key prediction of the model is that the distribution of the synthase is substantially broader than the area occupied by the exocyst. This prediction is borne out by our quantitative measurements. Thus, although the model highlights detailed issues that require further investigation, in general terms the pattern of tip growth of fungal hyphae can be satisfactorily explained by a simple but quantitative model rooted within the known molecular processes of polarized growth. Moreover, the methodology can be readily adapted to model other forms of polarized growth, such as that which occurs in plant pollen tubes. PMID:23666623

  12. Liquid-intake flow around the tip of butterfly proboscis.

    PubMed

    Lee, Sang Joon; Lee, Seung Chul; Kim, Bo Heum

    2014-05-07

    Butterflies drink liquid through a slender proboscis using a large pressure gradient induced by the systaltic operation of a muscular pump inside their head. Although the proboscis is a naturally well-designed coiled micro conduit for liquid uptake and deployment, it has been regarded as a simple straw connected to the muscular pump. There are few studies on the transport of liquid food in the proboscis of a liquid-feeding butterfly. To understand the liquid-feeding mechanism in the proboscis of butterflies, the intake flow around the tip of the proboscis was investigated in detail. In this study, the intake flow was quantitatively visualized using a micro-PIV (particle image velocimetry) velocity field measurement technique. As a result, the liquid-feeding process consists of an intake phase, an ejection phase and a rest phase. When butterflies drink pooled liquid, the liquid is not sucked into the apical tip of the proboscis, but into the dorsal linkage aligned longitudinally along the proboscis. To analyze main characteristics of the intake flow around a butterfly proboscis, a theoretical model was established by assuming that liquid is sucked into a line sink whose suction rate linearly decreases proximally. In addition, the intake flow around the tip of a female mosquito׳s proboscis which has a distinct terminal opening was also visualized and modeled for comparison. The present results would be helpful to understand the liquid-feeding mechanism of a butterfly. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Fabrication and Evaluation of a Noncompliant Molar Distalizing Appliance: Bonded Molar Distalizer

    PubMed Central

    Sodagar, A.; Ahmad Akhoundi, M. S.; Rafighii, A.; Arab, S.

    2011-01-01

    Objective Attempts to treat class II malocclusions without extraction in non-compliant patients have led to utilization of intraoral molar distalizing appliances. The purpose of this study was to investigate dental and skeletal effects of Bonded Molar Distalizer (BMD) which is a simple molar distalizing appliance. Materials and Methods Sixteen patients (12 girls, four boys) with bilateral half-cusp class II molar relationship, erupted permanent second molars and normal or vertical growth pattern were selected for bilateral distalization of maxillary molars via BMD. The screws were activated every other day, alternately. Lateral cephalograms and study models were obtained before treatment and after 11 weeks activation of the appliance. Results Significant amounts of molar distalization, molar distal tipping and anchorage loss were observed. The mean maxillary first molar distal movement was 1.22±0.936 mm with a distal tipping of 2.97±3.74 degrees in 11 weeks. The rate of distal movement was 0.48 mm per month. Reciprocal mesial movement of the first premolars was 2.26±1.12 mm with a mesial tipping of 4.25±3.12 degrees. Maxillary incisors moved 3.55±1.46 mm and tipped 9.87±5.03 degrees mesially. Lower anterior face height (LAFH) decreased 1.28±1.36 mm. Conclusion BMD is appropriate for distalizing maxillary molars, especially in patients with critical LAFH, although significant amounts of anchorage loss occur using this appliance. PMID:22457837

  14. Axial compressor blade design for desensitization of aerodynamic performance and stability to tip clearance

    NASA Astrophysics Data System (ADS)

    Erler, Engin

    Tip clearance flow is the flow through the clearance between the rotor blade tip and the shroud of a turbomachine, such as compressors and turbines. This flow is driven by the pressure difference across the blade (aerodynamic loading) in the tip region and is a major source of loss in performance and aerodynamic stability in axial compressors of modern aircraft engines. An increase in tip clearance, either temporary due to differential radial expansion between the blade and the shroud during transient operation or permanent due to engine wear or manufacturing tolerances on small blades, increases tip clearance flow and results in higher fuel consumption and higher risk of engine surge. A compressor design that can reduce the sensitivity of its performance and aerodynamic stability to tip clearance increase would have a major impact on short and long-term engine performance and operating envelope. While much research has been carried out on improving nominal compressor performance, little had been done on desensitization to tip clearance increase beyond isolated observations that certain blade designs such as forward chordwise sweep, seem to be less sensitive to tip clearance size increase. The current project aims to identify through a computational study the flow features and associated mechanisms that reduces sensitivity of axial compressor rotors to tip clearance size and propose blade design strategies that can exploit these results. The methodology starts with the design of a reference conventional axial compressor rotor followed by a parametric study with variations of this reference design through modification of the camber line and of the stacking line of blade profiles along the span. It is noted that a simple desensitization method would be to reduce the aerodynamic loading of the blade tip which would reduce the tip clearance flow and its proportional contribution to performance loss. However, with the larger part of the work on the flow done in this region, this approach would entail a nominal performance penalty. Therefore, the chosen rotor design philosophy aims to keep the spanwise loading constant to avoid trading performance for desensitization. The rotor designs that resulted from this exercise are simulated in ANSYS CFX at different tip clearance sizes. The change in their performance with respect to tip clearance size (sensitivity) is compared both on an integral level in terms of pressure ratio and adiabatic efficiency, as well as on a detailed level in terms of aerodynamic losses and blockage associated with tip clearance flow. The sensitivity of aerodynamic stability is evaluated either directly through the simulations of the rotor characteristics up to the stall point (expensive in time and resources) for a few designs or indirectly through the position of the interface between the incoming and tip clearance flow with respect to the rotor leading edge plane. The latter approach is based on a generally observed stall criteria in modern axial compressors. The rotor designs are then assessed according to their sensitivity in comparison to that of the reference rotor design to detect features that can explain the trend in sensitivity to tip clearance size. These features can then be validated and the associated flow mechanisms explained through numerical simulations and modelling. Analysis of the database from the rotor parametric study shows that the observed trend in sensitivity cannot be explained by the shifting of the aerodynamic loading along the blade chord, as initially hypothesized based on the literature review. Instead, two flow features are found to reduce sensitivity of performance and stability to tip clearance, namely an increase in incoming meridional momentum in the tip region and a reduction/elimination of double leakage flow. Double leakage flow is the flow that exits the tip clearance of one blade and proceeds into the clearance of the adjacent blade rather than convecting downstream out of the local blade passage. These flow features are isolated and validated based on the reference rotor design through changes in the inlet total pressure condition to alter incoming flow momentum and blade number count to change double leakage rate. In terms of flow mechanism, double leakage is shown to be detrimental to performance and stability, and its proportional increase with tip clearance size explains the sensitivity increase in the presence of double leakage and, conversely, the desensitization effect of reducing or eliminating double leakage. The increase in incoming meridional momentum in the tip region reduces sensitivity to tip clearance through its reduction of double leakage as well as through improved mixing with tip clearance flow, as demonstrated by an analytical model without double leakage flow. The above results imply that any blade design strategy that exploits the two desensitizing flow features would reduce the performance and stability sensitivity to tip clearance size. The increase of the incoming meridional momentum can be achieved through forward chordwise sweep of the blade. The reduction of double leakage without changing blade pitch can be obtained by decreasing the blade stagger angle in the tip region. Examples of blade designs associated with these strategies are shown through CFX simulations to be successful in reducing sensitivity to tip clearance size.

  15. Hidden dangers revealed by misdiagnosed diabetic neuropathy: A comparison of simple clinical tests for the screening of vibration perception threshold at primary care level.

    PubMed

    Azzopardi, Kurt; Gatt, Alfred; Chockalingam, Nachiappan; Formosa, Cynthia

    2018-04-01

    Diabetic peripheral neuropathy is an important complication and contributes to the morbidity of diabetes mellitus. Evidence indicates early detection of diabetic peripheral neuropathy results in fewer foot ulcers and amputations. The aim of this study was to compare different screening modalities in the detection of diabetic peripheral neuropathy in a primary care setting. A prospective non-experimental comparative multi-centre cross sectional study was conducted in various Primary Health Centres. One hundred participants living with Type 2 diabetes for at least 10 years were recruited using a convenience sampling method. The Vibratip, 128Hz tuning fork and neurothesiometer were compared in the detection of vibration perception. This study showed different results of diabetic peripheral neuropathy screening tests, even in the same group of participants. This study has shown that the percentage of participants who did not perceive vibrations was highest when using the VibraTip (28.5%). This was followed by the neurothesiometer (21%) and the 128Hz tuning fork (12%) (p<0.001). Correct diagnosis and treatment of neuropathy in patients with diabetes is crucial. This study demonstrates that some instruments are more sensitive to vibration perception than others. We recommend that different modalities should be used in patients with diabetes and when results do not concur, further neurological evaluation should be performed. This would significantly reduce the proportion of patients with diabetes who would be falsely identified as having no peripheral neuropathy and subsequently denied the benefit of beneficial and effective secondary risk factor control. Copyright © 2017 Primary Care Diabetes Europe. Published by Elsevier Ltd. All rights reserved.

  16. Helicopter vibration suppression using simple pendulum absorbers on the rotor blade

    NASA Technical Reports Server (NTRS)

    Hamouda, M.-N. H.; Pierce, G. A.

    1981-01-01

    A design procedure is presented for the installation of simple pendulums on the blades of a helicopter rotor to suppress the root reactions. The procedure consists of a frequency response analysis for a hingeless rotor blade excited by a harmonic variation of spanwise airload distributions during forward flight, as well as a concentrated load at the tip. The structural modeling of the blade provides for elastic degrees of freedom in flap and lead-lag bending plus torsion. Simple flap and lead-lag pendulums are considered individually. Using a rational order scheme, the general nonlinear equations of motion are linearized. A quasi-steady aerodynamic representation is used in the formation of the airloads. The solution of the system equations derives from their representation as a transfer matrix. The results include the effect of pendulum tuning on the minimization of the hub reactions.

  17. Using simple manipulatives to improve student comprehension of a complex biological process: protein synthesis.

    PubMed

    Guzman, Karen; Bartlett, John

    2012-01-01

    Biological systems and living processes involve a complex interplay of biochemicals and macromolecular structures that can be challenging for undergraduate students to comprehend and, thus, misconceptions abound. Protein synthesis, or translation, is an example of a biological process for which students often hold many misconceptions. This article describes an exercise that was developed to illustrate the process of translation using simple objects to represent complex molecules. Animations, 3D physical models, computer simulations, laboratory experiments and classroom lectures are also used to reinforce the students' understanding of translation, but by focusing on the simple manipulatives in this exercise, students are better able to visualize concepts that can elude them when using the other methods. The translation exercise is described along with suggestions for background material, questions used to evaluate student comprehension and tips for using the manipulatives to identify common misconceptions. Copyright © 2012 Wiley Periodicals, Inc.

  18. How to Connect With Parents by Using Updated Lamaze Messages

    PubMed Central

    Gatewood, Ashley C.

    2009-01-01

    Lamaze International partnered with Edelman, an international public relations firm, to re-brand the organization through its messaging to elevate its relevance among key stakeholders. Sound primary and secondary research revealed new ways to communicate the Lamaze message to women, their families, and their care providers. Various tips and tools are presented in this article to enable childbirth educators, care providers, and birth advocates to communicate these new messages more effectively to parents. PMID:20514122

  19. Ready to Succeed in the Classroom: Summary Report. Teachers' Advice, Strategies and Tips to Help Students in the Foster Care System Succeed in the Classroom.

    ERIC Educational Resources Information Center

    Center for the Future of Teaching and Learning, 2010

    2010-01-01

    The issue of improving educational outcomes for children and youth in foster care is receiving some long-overdue attention, but the voices of classroom teachers have not been prominent in the discussions so far. To help fill this gap, a team from the Center for the Future of Teaching and Learning and funded by the Stuart Foundation convened six…

  20. A self-fitting hearing aid: need and concept.

    PubMed

    Convery, Elizabeth; Keidser, Gitte; Dillon, Harvey; Hartley, Lisa

    2011-12-01

    The need for reliable access to hearing health care services is growing globally, particularly in developing countries and in remotely located, underserved regions in many parts of the developed world. Individuals with hearing loss in these areas are at a significant disadvantage due to the scarcity of local hearing health care professionals and the high cost of hearing aids. Current approaches to making hearing rehabilitation services more readily available to underserved populations include teleaudiology and the provision of amplification devices outside of the traditional provider-client relationship. Both strategies require access to such resources as dedicated equipment and/or specially trained staff. Another possible strategy is a self-fitting hearing aid, a personal amplification device that is equipped with an onboard tone generator to enable user-controlled, automated, in situ audiometry; an onboard prescription to determine the initial hearing aid settings; and a trainable algorithm to enable user-controlled fine-tuning. The device is thus assembled, fitted, and managed by the user without the need for audiological or computer support. This article details the self-fitting concept and its potential application in both developing and developed countries. Potential advantages and disadvantages of such a device are discussed, and considerations for further investigations into the concept are presented. Overall, the concept is considered technologically viable with the main challenges anticipated to be development of clear, simple user instructions and a delivery model that ensures reliable supplies of instant-fit ear tips and batteries.

  1. A Self-Fitting Hearing Aid

    PubMed Central

    Keidser, Gitte; Dillon, Harvey; Hartley, Lisa

    2011-01-01

    The need for reliable access to hearing health care services is growing globally, particularly in developing countries and in remotely located, underserved regions in many parts of the developed world. Individuals with hearing loss in these areas are at a significant disadvantage due to the scarcity of local hearing health care professionals and the high cost of hearing aids. Current approaches to making hearing rehabilitation services more readily available to underserved populations include teleaudiology and the provision of amplification devices outside of the traditional provider-client relationship. Both strategies require access to such resources as dedicated equipment and/or specially trained staff. Another possible strategy is a self-fitting hearing aid, a personal amplification device that is equipped with an onboard tone generator to enable user-controlled, automated, in situ audiometry; an onboard prescription to determine the initial hearing aid settings; and a trainable algorithm to enable user-controlled fine-tuning. The device is thus assembled, fitted, and managed by the user without the need for audiological or computer support. This article details the self-fitting concept and its potential application in both developing and developed countries. Potential advantages and disadvantages of such a device are discussed, and considerations for further investigations into the concept are presented. Overall, the concept is considered technologically viable with the main challenges anticipated to be development of clear, simple user instructions and a delivery model that ensures reliable supplies of instant-fit ear tips and batteries. PMID:22143873

  2. A Hopping Good Time: Wood Frogs in the Classroom.

    ERIC Educational Resources Information Center

    Shimkanin, John; Ulm, Glenn; King, Trina

    1998-01-01

    Presents a case for using wood frogs to study biology with students. Offers tips on where to find the eggs, how to care for them, what to expect as they hatch, and how to engage students in a study of their stages of development. (DDR)

  3. Finding the Right Dentist and Other Tips for Accessing Dental Care

    ERIC Educational Resources Information Center

    Blende, David M.

    2008-01-01

    National health surveys prove that people with disabilities receive fewer routine health examinations, fewer immunizations, less mental healthcare, less prophylactic oral healthcare, and fewer opportunities for physical exercise and athletic achievement than do other Americans. Those with communication difficulties are especially at greater risk…

  4. Technology's Role in Security.

    ERIC Educational Resources Information Center

    Day, C. William

    1999-01-01

    Examines the use of technology to bolster the school security system, tips on selecting a security consultant, and several basic strategies to make buildings and grounds safer. Technological ideas discussed include the use of telephones in classrooms to expedite care in emergency situations, surveillance cameras to reduce crime, and metal…

  5. Stressed Out in the Classroom.

    ERIC Educational Resources Information Center

    Black, Susan

    2003-01-01

    Many teachers feel overwhelmed about meeting the needs of students getting ready for tests, and about relations with principals. Four exceptionally high-stress factors that teachers admit carrying into their classrooms are money management, health, relationships, and care giving. A sidebar lists tips for administrators to help alleviate teachers'…

  6. Developing Multiple Choice Tests: Tips & Techniques

    ERIC Educational Resources Information Center

    McCowan, Richard J.

    1999-01-01

    Item writing is a major responsibility of trainers. Too often, qualified staff who prepare lessons carefully and teach conscientiously use inadequate tests that do not validly reflect the true level of trainee achievement. This monograph describes techniques for constructing multiple-choice items that measure student performance accurately. It…

  7. Stretch That Budget!

    ERIC Educational Resources Information Center

    Walker, John R.

    1976-01-01

    Discusses ways in which industrial education teachers can stretch their budgets, which include reducing waste to a minimum, keeping an accurate and up-to-date inventory, trading surplus or excess materials with neighboring schools, and planning programs more carefully. Money-saving tips concerned with metals, plastics, woods, and printing are also…

  8. Menu Plans: Maximum Nutrition for Minimum Cost.

    ERIC Educational Resources Information Center

    Texas Child Care, 1995

    1995-01-01

    Suggests that menu planning is the key to getting maximum nutrition in day care meals and snacks for minimum cost. Explores United States Department of Agriculture food pyramid guidelines for children and tips for planning menus and grocery shopping. Includes suggested meal patterns and portion sizes. (HTH)

  9. Struggling to Sleep? Don't Let Apnea Steal Your Sweet Dreams

    MedlinePlus

    ... may be considered with advice from a physician familiar with your health. Everyone deserves a good night’s sleep. For self-care tips for breathing better while you’re sleeping, see the “Wise Choices” box. If you feel extremely sleepy during the ...

  10. Buyer's Guide to Classroom Furniture.

    ERIC Educational Resources Information Center

    Neugebauer, Roger

    1996-01-01

    Provides advice to child care center directors on purchasing the center's furniture. Contains a series of questions that directors should ask related to purchasing furniture, based on advice from manufacturers and dealers. Summarizes the key factors needed to consider when purchasing classroom furniture and includes tips on buying from catalogs…

  11. Business plans--tips from the toolkit 6.

    PubMed

    Steer, Neville

    2010-07-01

    General practice is a business. Most practices can stay afloat by having appointments, billing patients, managing the administration processes and working long hours. What distinguishes the high performance organisation from the average organisation is a business plan. This article examines how to create a simple business plan that can be applied to the general practice setting and is drawn from material contained in The Royal Australian College of General Practitioners' 'General practice management toolkit'.

  12. Herediatary anhidrotic ectodermal dysplasia. Studies in a Nigerian famil.

    PubMed

    Familusi, J B; Jaiyesimi, F; Ojo, C O; Attah, E B

    1975-08-01

    Studies in a Nigerian family with hereditary anhidrous ectodermal dysplasia are reported. Microscopical examinations of finger tips for sweat pores were diagnostic in phenotypes, and it is suggested that this simple nonsurgical procedure is a preferred alternative to skin biopsies in the diagnosis of the syndrome. The clinical implications of a tropical environment for the syndrome, as well as the factors that may favour maintenance of the gene in such an environment are discussed.

  13. You Have to Go to School - You're the Principal!: 101 Tips to Make It Better for Your Students, Your Staff, and Yourself

    ERIC Educational Resources Information Center

    Young, Paul G.

    2004-01-01

    What if you already had thirty-years' experience on your first day as a principal? What if, after 20 years as a principal, you felt as fresh and energized as you did on your first day? Principals need encouragement and revitalization for their school and their careers. Full of simple rules and meaningful insights, this compilation of suggestions…

  14. Universal aspects of brittle fracture, adhesion, and atomic force microscopy

    NASA Technical Reports Server (NTRS)

    Banerjea, Amitava; Ferrante, John; Smith, John R.

    1989-01-01

    This universal relation between binding energy and interatomic separation was originally discovered for adhesion at bimetallic interfaces involving the simple metals Al, Zn, Mg, and Na. It is shown here that the same universal relation extends to adhesion at transition-metal interfaces. Adhesive energies have been computed for the low-index interfaces of Al, Ni, Cu, Ag, Fe, and W, using the equivalent-crystal theory (ECT) and keeping the atoms in each semiinfinite slab fixed rigidly in their equilibrium positions. These adhesive energy curves can be scaled onto each other and onto the universal adhesion curve. The effect of tip shape on the adhesive forces in the atomic-force microscope (AFM) is studied by computing energies and forces using the ECT. While the details of the energy-distance and force-distance curves are sensitive to tip shape, all of these curves can be scaled onto the universal adhesion curve.

  15. Analysis of a photon assisted field emission device

    NASA Astrophysics Data System (ADS)

    Jensen, K. L.; Lau, Y. Y.; McGregor, D. S.

    2000-07-01

    A field emitter array held at the threshold of emission by a dc gate potential from which current pulses are triggered by the application of a laser pulse on the backside of the semiconductor may produce electron bunches ("density modulation") at gigahertz frequencies. We develop an analytical model of such optically controlled emission from a silicon tip using a modified Wentzel-Kramers-Brillouin and Airy function approach to solving Schrödinger's equation. Band bending and an approximation to the exchange-correlation effects on the image charge potential are included for an array of hyperbolic emitters with a distribution in tip radii and work function. For a simple relationship between the incident photon flux and the resultant electron density at the emission site, an estimation of the tunneling current is made. An example of the operation and design of such a photon-assisted field emission device is given.

  16. Fostering collaboration in the medical practice: twenty-five tips.

    PubMed

    Hills, Laura

    2013-01-01

    It's a given that collaboration is an important aspect of medical practice management. But achieving genuine collaboration among the members of your medical practice team may not be as simple as it seems. This article suggests 25 practical strategies for medical practice employees and their managers to help them create and foster collaboration in their medical practices. Tips for collaborative goal setting, communication, ground rules, task delineation, sustainability, problem solving, and anticipating and handling problems are all described. In addition, this article offers a four-step strategy for dealing with a domineering collaborator and a five-step strategy for dealing with a collaboration slacker. This article also includes a 20-question self-quiz to help you and your employees evaluate your collaborative work style. Finally, this article describes 10 common collaboration pitfalls and the strategies you and your staff can use to avoid falling victim to them.

  17. Calculation of stress intensity factors in an isotropic multicracked plate: Part 2: Symbolic/numeric implementation

    NASA Technical Reports Server (NTRS)

    Arnold, S. M.; Binienda, W. K.; Tan, H. Q.; Xu, M. H.

    1992-01-01

    Analytical derivations of stress intensity factors (SIF's) of a multicracked plate can be complex and tedious. Recent advances, however, in intelligent application of symbolic computation can overcome these difficulties and provide the means to rigorously and efficiently analyze this class of problems. Here, the symbolic algorithm required to implement the methodology described in Part 1 is presented. The special problem-oriented symbolic functions to derive the fundamental kernels are described, and the associated automatically generated FORTRAN subroutines are given. As a result, a symbolic/FORTRAN package named SYMFRAC, capable of providing accurate SIF's at each crack tip, was developed and validated. Simple illustrative examples using SYMFRAC show the potential of the present approach for predicting the macrocrack propagation path due to existing microcracks in the vicinity of a macrocrack tip, when the influence of the microcrack's location, orientation, size, and interaction are taken into account.

  18. Purification process for vertically aligned carbon nanofibers

    NASA Technical Reports Server (NTRS)

    Nguyen, Cattien V.; Delziet, Lance; Matthews, Kristopher; Chen, Bin; Meyyappan, M.

    2003-01-01

    Individual, free-standing, vertically aligned multiwall carbon nanotubes or nanofibers are ideal for sensor and electrode applications. Our plasma-enhanced chemical vapor deposition techniques for producing free-standing and vertically aligned carbon nanofibers use catalyst particles at the tip of the fiber. Here we present a simple purification process for the removal of iron catalyst particles at the tip of vertically aligned carbon nanofibers derived by plasma-enhanced chemical vapor deposition. The first step involves thermal oxidation in air, at temperatures of 200-400 degrees C, resulting in the physical swelling of the iron particles from the formation of iron oxide. Subsequently, the complete removal of the iron oxide particles is achieved with diluted acid (12% HCl). The purification process appears to be very efficient at removing all of the iron catalyst particles. Electron microscopy images and Raman spectroscopy data indicate that the purification process does not damage the graphitic structure of the nanotubes.

  19. Measuring protein-protein and protein-nucleic Acid interactions by biolayer interferometry.

    PubMed

    Sultana, Azmiri; Lee, Jeffrey E

    2015-02-02

    Biolayer interferometry (BLI) is a simple, optical dip-and-read system useful for measuring interactions between proteins, peptides, nucleic acids, small molecules, and/or lipids in real time. In BLI, a biomolecular bait is immobilized on a matrix at the tip of a fiber-optic sensor. The binding between the immobilized ligand and another molecule in an analyte solution produces a change in optical thickness at the tip and results in a wavelength shift proportional to binding. BLI provides direct binding affinities and rates of association and dissociation. This unit describes an efficient approach using streptavidin-based BLI to analyze DNA-protein and protein-protein interactions. A quantitative set of equilibrium binding affinities (K(d)) and rates of association and dissociation (k(a)/k(d)) can be measured in minutes using nanomole quantities of sample. Copyright © 2015 John Wiley & Sons, Inc.

  20. Measurement of the Critical Distance Parameter Against Icing Conditions on a NACA 0012 Swept Wing Tip

    NASA Technical Reports Server (NTRS)

    Vargas, Mario; Kreeger, Richard E.

    2011-01-01

    This work presents the results of three experiments, one conducted in the Icing Research Tunnel (IRT) at NASA Glenn Research Center and two in the Goodrich Icing Wind Tunnel (IWT). The experiments were designed to measure the critical distance parameter on a NACA 0012 Swept Wing Tip at sweep angles of 45deg, 30deg, and 15deg. A time sequence imaging technique (TSIT) was used to obtain real time close-up imaging data during the first 2 min of the ice accretion formation. The time sequence photographic data was used to measure the critical distance at each icing condition and to study how it develops in real time. The effect on the critical distance of liquid water content, drop size, total temperature, and velocity was studied. The results were interpreted using a simple energy balance on a roughness element

  1. Tipping points in the arctic: eyeballing or statistical significance?

    PubMed

    Carstensen, Jacob; Weydmann, Agata

    2012-02-01

    Arctic ecosystems have experienced and are projected to experience continued large increases in temperature and declines in sea ice cover. It has been hypothesized that small changes in ecosystem drivers can fundamentally alter ecosystem functioning, and that this might be particularly pronounced for Arctic ecosystems. We present a suite of simple statistical analyses to identify changes in the statistical properties of data, emphasizing that changes in the standard error should be considered in addition to changes in mean properties. The methods are exemplified using sea ice extent, and suggest that the loss rate of sea ice accelerated by factor of ~5 in 1996, as reported in other studies, but increases in random fluctuations, as an early warning signal, were observed already in 1990. We recommend to employ the proposed methods more systematically for analyzing tipping points to document effects of climate change in the Arctic.

  2. Functionalized core-shell hydrogel microsprings by anisotropic gelation with bevel-tip capillary

    PubMed Central

    Yoshida, Koki; Onoe, Hiroaki

    2017-01-01

    This study describes a novel microfluidic-based method for the synthesis of hydrogel microsprings that are capable of encapsulating various functional materials. A continuous flow of alginate pre-gel solution can spontaneously form a hydrogel microspring by anisotropic gelation around the bevel-tip of the capillary. This technique allows fabrication of hydrogel microsprings using only simple capillaries and syringe pumps, while their complex compartmentalization characterized by a laminar flow inside the capillary can contribute to the optimization of the microspring internal structure and functionality. Encapsulation of several functional materials including magnetic-responsive nanoparticles or cell dispersed collagen for tissue scaffold was demonstrated to functionalize the microsprings. Our core-shell hydrogel microsprings have immense potential for application in a number of fields, including biological/chemical microsensors, biocompatible soft robots/microactuators, drug release, self-assembly of 3D structures and tissue engineering. PMID:28378803

  3. Genotoxicity of municipal landfill leachate on root tips of Vicia faba.

    PubMed

    Sang, Nan; Li, Guangke

    2004-06-13

    The genotoxicity of municipal landfill leachate was studied using the Vicia faba root-tip cytogenetic bioassay. Results show that landfill leachates collected in different seasons decreased the mitotic index (MI) and caused significant increases of micronucleus (MN) frequencies and anaphase aberration (AA) frequencies in a concentration-dependent manner (concentration expressed as 'chemical oxygen demand' measured by the method of potassium dichromate oxidation (COD(Cr))). In addition, a seasonal difference in genotoxicity induced by leachate was observed. The results confirm that leachate is a genotoxic agent in plant cells and imply that exposure to leachate in the aquatic environment may pose a potential genotoxic risk to organisms. The results also show that the V. faba cytogenetic bioassay is efficient, simple and reproducible in genotoxicity studies of leachate, and that there is a correlation between the genotoxicity and the chemical measurement (COD(Cr)) of leachate.

  4. Local electrophoretic deposition using a nanopipette for micropillar fabrication

    NASA Astrophysics Data System (ADS)

    Iwata, Futoshi; Metoki, Junya

    2017-12-01

    A novel and simple technique was developed for the fabrication of micropillars using a nanopipette that is a tapered glass capillary with a micrometer-sized aperture at the tip. The nanopipette was filled with a colloidal solution that included metal nanoparticles. Its tip was put in contact with a substrate, and the substrate was moved downward for continuous deposition of the metal colloidal solution to form micropillars. To improve fabrication reproducibility, the amount of Au colloidal solution deposited was controlled by a feedback loop that maintained a predefined constant current during electrophoretic deposition. The stiffness of the fabricated micropillars was evaluated by applying a loading force using a microcantilever under scanning electron microscopy. The Young’s modulus of the fabricated pillars was measured to be in the range of 7.7-14.8 GPa, depending on the fabrication parameters of the predefined current and fabrication speed.

  5. Intravascular ultrasound in coronary atherosclerosis: a new approach to clinical assessment.

    PubMed

    Liebson, P R; Klein, L W

    1992-06-01

    Intravascular ultrasound evaluation of the coronary arteries by means of a selective coronary catheter attached to an ultrasound unit has afforded precise depiction of coronary lumen diameter and area at the level of the catheter tip. The arterial wall at this level can be evaluated for lipid, fibrous tissue, calcification, wall dissections, and intraluminal thrombi. The technique has the advantage over coronary angioscopy and angiography in that it does not require infusions or injections to allow visualization, and it has the ability to depict the inside of the arterial wall. The current disadvantages include the inability to visualize the vessel segments distal to the catheter tip. Three-dimensional reconstruction techniques allow depiction of the segment of the artery traversed by the catheter tip. The use of Doppler ultrasound imaging provides information on coronary flow velocities through coronary obstructions. Intravascular ultrasound images may provide information that complements the coronary arteriogram and may have an impact on patient care and clinical investigation strategies.

  6. Influence of the expansion screw height on the dental effects of the hyrax expander: a study with finite elements.

    PubMed

    Araugio, Rafael Marques de Sousa; Landre, Jánes; Silva, Diana de Lourdes Almeida; Pacheco, Wellington; Pithon, Matheus Melo; Oliveira, Dauro Douglas

    2013-02-01

    Our objective was to evaluate the influence of the expansion screw height of a hyrax expander on the degree of dental inclination during rapid maxillary expansion by using the finite element method. The hyrax expander and the maxillary arch were modeled by using Solidworks software (Dassault Systèmes, Paris, France). Three distinct finite element method models were created by simulating different screw heights relative to the plane that intersected the center of resistance of the maxillary first molars. These 3 relative positions were 10 mm below the maxillary first molars' center of resistance, at the same level as the maxillary first molars' center of resistance, and 10 mm above the maxillary first molars' center of resistance. The initial activation of the expanders was simulated, and tooth displacements for each finite element method model were registered in the buccolingual, corono-apical, and mesiodistal directions. The simulations tested showed that the 3 hyrax screw heights had different dental tipping tendencies. When the screw was simulated below the maxillary first molars' center of resistance, buccal tipping of the crowns and lingual tipping of the roots were registered. This tendency decreased when the screw was simulated at the same level as the maxillary first molars' center of resistance. However, when the screw was simulated above the maxillary first molars' center of resistance, the tipping tendency was inverted, with the crowns displaying lingual tipping and the roots displaying buccal tipping. These findings might explain the importance of carefully planning the height of the hyrax expander screw, since, depending on this position, different tooth movements can be achieved. From an orthopedic perspective, the ideal screw position might be slightly above the maxillary first molars' center of resistance; this would generate less dental tipping. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  7. Intraoperative use of a tablet computer to aid rhinoplasty.

    PubMed

    Tsounis, M; Papadopoulou, D; Faris, C

    2017-01-01

    Open septorhinoplasty enables excellent exposure to the structural components of the nasal tip. Nevertheless, it runs the risk of weakening its support mechanisms, which can lead to notable changes to tip projection and rotation as well as to the nasolabial angle. It is therefore paramount that the surgeon reconstructs the nose to the desired endpoint at the end of the operation. Currently, the gold standard of care in rhinoplasty uses preoperative photographs with the patient sitting or standing. However, this is not a true representation of the face in the operative position as the patient is placed supine and so gravity affects the appearance of the nose in a different way. Other factors such as head drapes and traction on the endotracheal tube can also cause subtle changes. We therefore advocate additional intraoperative profile view photographs to improve the accuracy of nasal tip positioning. In our department, in addition to standard preoperative photographs, immediate preoperative profile photos are taken with the patient supine, intubated and draped. Images are captured using a tablet computer at a distance of 1 meter from the patient. We ensure that the Frankfort plane is perpendicular to the floor. The picture is enlarged so that the image is full scale and the tablet is subsequently placed immediately behind the patient for direct comparison. This is then used during the procedure to check tip projection and rotation as well as at the end of the procedure following closure of the columellar incision to ensure correct placement of the nasal tip.

  8. Stability analysis of multiple-robot control systems

    NASA Technical Reports Server (NTRS)

    Wen, John T.; Kreutz, Kenneth

    1989-01-01

    In a space telerobotic service scenario, cooperative motion and force control of multiple robot arms are of fundamental importance. Three paradigms to study this problem are proposed. They are distinguished by the set of variables used for control design. They are joint torques, arm tip force vectors, and an accelerated generalized coordinate set. Control issues related to each case are discussed. The latter two choices require complete model information, which presents practical modeling, computational, and robustness problems. Therefore, focus is on the joint torque control case to develop relatively model independent motion and internal force control laws. The rigid body assumption allows the motion and force control problems to be independently addressed. By using an energy motivated Lyapunov function, a simple proportional derivative plus gravity compensation type of motion control law is always shown to be stabilizing. The asymptotic convergence of the tracing error to zero requires the use of a generalized coordinate with the contact constraints taken into account. If a non-generalized coordinate is used, only convergence to a steady state manifold can be concluded. For the force control, both feedforward and feedback schemes are analyzed. The feedback control, if proper care has been taken, exhibits better robustness and transient performance.

  9. Aerodynamic Analysis of Variable Geometry Raked Wingtips for Mid-Range Transonic Transport Aircraft

    NASA Astrophysics Data System (ADS)

    Jingeleski, David J.

    Previous applications have shown that a wingtip treatment on a commercial airliner will reduce drag and increase fuel efficiency and the most common types of treatment are blended winglets and raked wingtips. With Boeing currently investigating novel designs for its next generation of airliners, a variable geometry raked wingtip novel control effector (VGRWT/NCE) was studied to determine the aerodynamic performance benefits over an untreated wingtip. The Boeing SUGAR design employing a truss-braced wing was selected as the baseline. Vortex lattice method (VLM) and computational fluid dynamics (CFD) software was implemented to analyze the aerodynamic performance of such a configuration applied to a next-generation, transonic, mid-range transport aircraft. Several models were created to simulate various sweep positions for the VGRWT/NCE tip, as well as a baseline model with an untreated wingtip. The majority of investigation was conducted using the VLM software, with CFD used largely as a validation of the VLM analysis. The VGRWT/NCE tip was shown to increase the lift of the wing while also decreasing the drag. As expected, the unswept VGRWT/NCE tip increases the amount of lift available over the untreated wingtip, which will be very beneficial for take-off and landing. Similarly, the swept VGRWT/NCE tip reduced the drag of the wing during cruise compared to the unmodified tip, which will favorably impact the fuel efficiency of the aircraft. Also, the swept VGRWT/NCE tip showed an increase in moment compared to the unmodified wingtip, implying an increase in stability, as well providing an avenue for roll control and gust alleviation for flexible wings. CFD analysis validated VLM as a useful low fidelity tool that yielded quite accurate results. The main results of this study are tabulated "deltas" in the forces and moments on the VGRWT/NCE tip as a function of sweep angle and aileron deflection compared to the baseline wing. A side study of the effects of the joint between the main wing and the movable tip showed that the drag impact can be kept small by careful design.

  10. Real time observation and automated measurement of red blood cells agglutination inside a passive microfluidic biochip containing embedded reagents.

    PubMed

    Huet, Maxime; Cubizolles, Myriam; Buhot, Arnaud

    2017-07-15

    The process of agglutination is commonly used for the detection of biomarkers like proteins or viruses. The multiple bindings between micrometer sized particles, either latex beads or red blood cells (RBCs), create aggregates that are easily detectable and give qualitative information about the presence of the biomarkers. In most cases, the detection is made by simple naked-eye observation of agglutinates without any access to the kinetics of agglutination. In this study, we address the development of a real-time time observation of RBCs agglutination. Using ABO blood typing as a proof-of-concept, we developed i) an integrated biological protocol suitable for further use as point-of-care (POC) analysis and ii) two dedicated image processing algorithms for the real-time and quantitative measurement of agglutination. Anti-A or anti-B typing reagents were dried inside the microchannel of a passive microfluidic chip designed to enhance capillary flow. A blood drop deposit at the tip of the biochip established a simple biological protocol. In situ agglutination of autologous RBCs was achieved by means of embedded reagents and real time agglutination process was monitored by video recording. Using a training set of 24 experiments, two real-time indicators based on correlation and variance of gray levels were optimized and then further confirmed on a validation set. 100% correct discrimination between positive and negative agglutinations was performed within less than 2min by measuring real-time evolution of both correlation and variance indicators. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Always Kiss Me Good Night.

    ERIC Educational Resources Information Center

    Salt, J. S.

    1997-01-01

    Presents practical parenting tips obtained from 1,000 children ages 6 to 12 years from a variety of ethnic and economic backgrounds. Common themes included children's desire to receive respect, caring, and guidance from their parents. The most frequent instructions to parents were: "Don't yell at me,""Help me with my homework,"…

  12. Taking Care of Your Behavioral Health: Tips for Social Distancing, Quarantine, and Isolation

    MedlinePlus

    ... REDUCE FINANCIAL STRESS If you’re unable to work during this time, you may experience stress related to your job status or financial situation. 2 Toll-Free: 1-877-SAMHSA-7 ... you are away from work. ƒ Contact the U.S. Department of Labor toll- free ...

  13. 10 Tips to Protect Yourself from Unhealthy Air

    MedlinePlus

    ... parts of the country. Use hand-powered or electric lawn care equipment rather than gasoline-powered. Old two-stroke engines like lawnmowers and leaf or snow blowers often have no pollution control devices. They can pollute the air even more than cars, though engines sold since 2011 are cleaner. Don' ...

  14. School-Age NOTES, 2000-2001.

    ERIC Educational Resources Information Center

    Scofield, Richard T., Ed.

    2001-01-01

    This document is comprised of the 12 monthly issues of a newsletter providing support and information for providers of child care for school-age children. The featured articles for each month are: (1) "Re-Evaluating Praise" (September); (2) "Making the Season Brighter: Tips To Create More Inclusive Holiday Programs" (October);…

  15. Do Sweat the Small Stuff! Marketing That Matters.

    ERIC Educational Resources Information Center

    Wassom, Julie

    1999-01-01

    Provides tips for building enrollment in child care programs. Offers suggestions for the inquiry call, including enhancing the greeting, asking questions, and using prospect profiles; for the center visit, including treating visitors like welcome guests, meeting privately first, and asking questions; and for followup, including setting up a…

  16. Celebrate the Earth...Every Day!

    ERIC Educational Resources Information Center

    Laubenthal, Gail

    1995-01-01

    Discusses the importance of teaching young children to appreciate and care for the earth and how to integrate earth activities into the curriculum. Includes a year-round curriculum with ideas for hands-on activities appropriate to each month, an integrated unit called "Flowers Blooming," tips for evaluating science experiences, and a…

  17. Developing great abstracts and posters: how to use the tools of science communication.

    PubMed

    Bingham, Raymond; O'Neal, Daniel

    2013-01-01

    All nurses, clinicians and researchers are encouraged to share information on the programs they develop or the studies they conduct. This communication serves to advance the knowledge and clinical wisdom of the nursing and other health care professions. One way to do this is to submit an abstract or poster to a conference, where you can present your findings to other health care professionals. This article gives useful tips for developing successful abstracts and posters. © 2013 AWHONN.

  18. A simple nonlocal damage model for predicting failure of notched laminates

    NASA Technical Reports Server (NTRS)

    Kennedy, T. C.; Nahan, M. F.

    1995-01-01

    The ability to predict failure loads in notched composite laminates is a requirement in a variety of structural design circumstances. A complicating factor is the development of a zone of damaged material around the notch tip. The objective of this study was to develop a computational technique that simulates progressive damage growth around a notch in a manner that allows the prediction of failure over a wide range of notch sizes. This was accomplished through the use of a relatively simple, nonlocal damage model that incorporates strain-softening. This model was implemented in a two-dimensional finite element program. Calculations were performed for two different laminates with various notch sizes under tensile loading, and the calculations were found to correlate well with experimental results.

  19. Primary Palliative Care for the General Internist: Integrating Goals of Care Discussions into the Outpatient Setting

    PubMed Central

    Ahia, Chad L.; Blais, Christopher M.

    2014-01-01

    Background Primary palliative care consists of the palliative care competencies required of all primary care clinicians. Included in these competencies is the ability to assist patients and their families in establishing appropriate goals of care. Goals of care help patients and their families understand the patient's illness and its trajectory and facilitate medical care decisions consistent with the patient's values and goals. General internists and family medicine physicians in primary care are central to getting patients to articulate their goals of care and to have these documented in the medical record. Case Report Here we present the case of a 71-year-old male patient with chronic obstructive pulmonary disorder, congestive heart failure, and newly diagnosed Alzheimer dementia to model pertinent end-of-life care communication and discuss practical tips on how to incorporate it into practice. Conclusion General internists and family medicine practitioners in primary care are central to eliciting patients' goals of care and achieving optimal end-of-life outcomes for their patients. PMID:25598737

  20. Study on flow over finite wing with respect to F-22 raptor, Supermarine Spitfire, F-7 BG aircraft wing and analyze its stability performance and experimental values

    NASA Astrophysics Data System (ADS)

    Ali, Md. Nesar; Alam, Mahbubul

    2017-06-01

    A finite wing is a three-dimensional body, and consequently the flow over the finite wing is three-dimensional; that is, there is a component of flow in the span wise direction. The physical mechanism for generating lift on the wing is the existence of a high pressure on the bottom surface and a low pressure on the top surface. The net imbalance of the pressure distribution creates the lift. As a by-product of this pressure imbalance, the flow near the wing tips tends to curl around the tips, being forced from the high-pressure region just underneath the tips to the low-pressure region on top. This flow around the wing tips is shown in the front view of the wing. As a result, on the top surface of the wing, there is generally a span wise component of flow from the tip toward the wing root, causing the streamlines over the top surface to bend toward the root. On the bottom surface of the wing, there is generally a span wise component of flow from the root toward the tip, causing the streamlines over the bottom surface to bend toward the tip. Clearly, the flow over the finite wing is three-dimensional, and therefore we would expect the overall aerodynamic properties of such a wing to differ from those of its airfoil sections. The tendency for the flow to "leak" around the wing tips has another important effect on the aerodynamics of the wing. This flow establishes a circulatory motion that trails downstream of the wing; that is, a trailing vortex is created at each wing tip. The aerodynamics of finite wings is analyzed using the classical lifting line model. This simple model allows a closed-form solution that captures most of the physical effects applicable to finite wings. The model is based on the horseshoe-shaped vortex that introduces the concept of a vortex wake and wing tip vortices. The downwash induced by the wake creates an induced drag that did not exist in the two-dimensional analysis. Furthermore, as wingspan is reduced, the wing lift slope decreases, and the induced drag increases, reducing overall efficiency. To complement the high aspect ratio wing case, a slender wing model is formulated so that the lift and drag can be estimated for this limiting case as well. We analyze the stability performance of F-22 raptor, Supermarine Spitfire, F-7 BG Aircraft wing by using experimental method and simulation software. The experimental method includes fabrication of F-22 raptor, Supermarine Spitfire, F-7 BG Aircraft wing which making material is Gamahr wood. Testing this model wing in wind tunnel test and after getting expected data we also compared this value with analyzing software data for furthermore experiment.

  1. Retail clinic visits and receipt of primary care.

    PubMed

    Reid, Rachel O; Ashwood, J Scott; Friedberg, Mark W; Weber, Ellerie S; Setodji, Claude M; Mehrotra, Ateev

    2013-04-01

    An increasing number of patients are visiting retail clinics for simple acute conditions. Physicians worry that visits to retail clinics will interfere with primary care relationships. No prior study has evaluated the impact of retail clinics on receipt of primary care. To assess the association between retail clinic use and receipt of key primary care functions. We performed a retrospective cohort analysis using commercial insurance claims from 2007 to 2009. We identified patients who had a visit for a simple acute condition in 2008, the "index visit". We divided these 127,358 patients into two cohorts according to the location of that index visit: primary care provider (PCP) versus retail clinic. We evaluated three functions of primary care: (1) where patients first sought care for subsequent simple acute conditions; (2) continuity of care using the Bice-Boxerman index; and (3) preventive care and diabetes management. Using a difference-in-differences approach, we compared care received in the 365 days following the index visit to care received in the 365 days prior, using propensity score weights to account for selection bias. Visiting a retail clinic instead of a PCP for the index visit was associated with a 27.7 visits per 100 patients differential reduction (p < 0 .001) in subsequent PCP visits for new simple acute conditions. Visiting a retail clinic instead of a PCP was also associated with decreased subsequent continuity of care (10.9 percentage-point differential reduction in Bice-Boxerman index, p < 0 .001). There was no differential change between the cohorts in receipt of preventive care or diabetes management. Retail clinics may disrupt two aspects of primary care: whether patients go to a PCP first for new conditions and continuity of care. However, they do not negatively impact preventive care or diabetes management.

  2. Enabling Desktop Nanofabrication with the Targeted Use of Soft Materials

    NASA Astrophysics Data System (ADS)

    Eichelsdoerfer, Daniel James

    This thesis focuses on the application of soft materials to scanning probe-based molecular printing techniques, such as dip-pen nanolithography (DPN). The selective incorporation of soft materials in place of hard materials in traditional cantilever-based scanning probe lithography (SPL) systems not only enables the deposition of a broader range of materials, but also dramatically lowers the cost while simultaneously increasing the throughput of SPL. Chapter 1 introduces SPL and DPN, and highlights a few recent advances in using DPN to control surface chemical functionality at the nanoscale. In addition to introducing the material deposition capabilities of DPN, Chapter 1 introduces the development of the cantilever-free architecture, a relatively recent paradigm shift in high-throughput SPL. Furthermore, an in-depth synthetic methodology for making the most widely used cantilever-free tip arrays, consisting of elastomeric nanoscale pens adhered to an elastomeric backing layer on a glass slide, is included as an appendix. Chapter 2 discusses the synthesis of metal and metal oxide nanoparticles at specified locations by using DPN to deposit the precursors dispersed in a polymer matrix; after deposition, the precursors are annealed to form single nanoparticles. This work builds on previous soft material-based advances in DPN by utilizing the polymer as a "nanoreactor" to synthesize the desired nanoparticles, where the precursors can diffuse and coalesce into a single nanoparticle within each spot. The process of precursor aggregation and single nanoparticle formation is studied, and it is found that metal precursors follow one of three pathways based upon their reduction potential. Chapter 3 is the first of three chapters that highlights the power of soft materials in the cantilever-free architecture. In particular, Chapter 3 examines the role of the elastomeric backing layer as a compliant spring whose stiffness (as measured by the spring constant, k) can be tuned with a simple chemical change to the composition of the elastomer. In particular, the extent of cross-linking within the elastomer is found to dictate the k the backing layer, and arrays with spring constants tuned from 7 to 150 N/m are described. Furthermore, a simple geometric model is developed that explains the low variation of k within each cantilever-free array; this stands in contrast to arrays of cantilevers, which typically show large variations of k within an array. Chapter 4 addresses the problem of individual actuation in SPL by embedding resistive heaters directly beneath the elastomeric backing layer. This actuation scheme was chosen because the elastomer used in the cantilever-free tip arrays has extraordinary thermal expansion properties, and thorough exploration of their actuation behavior shows that the heater arrays are fast (> 100 microm/s) and powerful (> 4 microm) enough for actuation. After implementing several corrections for the tip height -- a problem that is intractable without the heaters, and has never been addressed before -- printing of alkanethiols onto Au is demonstrated with a 2D array of individually actuated probes. Chapter 5 examines the hypothesis that elastomeric tips can absorb solvent and be used to transport materials in the absence of environmental solvent. This is evaluated by first using tip arrays soaked in a nonpolar solvent to pattern a hydrophobic block copolymer that cannot be patterned by traditional DPN, and is subsequently explored for the case of water uptake into the pen arrays. Surprisingly, despite their poor water retention ability, the tip arrays can store enough water to pattern hydrophilic polymers in dry environments for over 2 hours. The dynamics of the solvent absorption are captured by a simple calculation that accounts for the dynamical behavior of water retention and the backing layer thickness, thereby allowing these results to be generalized to other solvents. This exploration of the subtle and dynamic role of absorbed solvent in cantilever-free pen arrays shows that proper pre-treatment of the arrays can be used to obviate the need for an environmental chamber in molecular printing. (Abstract shortened by UMI.)

  3. Using the Nudge and Shove Methods to Adjust Item Difficulty Values.

    PubMed

    Royal, Kenneth D

    2015-01-01

    In any examination, it is important that a sufficient mix of items with varying degrees of difficulty be present to produce desirable psychometric properties and increase instructors' ability to make appropriate and accurate inferences about what a student knows and/or can do. The purpose of this "teaching tip" is to demonstrate how examination items can be affected by the quality of distractors, and to present a simple method for adjusting items to meet difficulty specifications.

  4. The Role of the Private Sector in the National Response System

    DTIC Science & Technology

    2013-12-01

    p. 1). In addition, the authors also stress some of the obstacles preventing even further cooperation including access to information, sharing...classified a disaster. However, a simple event, such as a cow tipping over a lantern in a barn, can lead to an entire city burning down, claiming 1,200 lives...thousands of people trapped in the stifling heat of the convention center and Superdome, these supplies would have been instrumental in helping them

  5. Effect of Winglets on a First-Generation Jet Transport Wing. 2: Pressure and Spanwise Load Distributions for a Semispan Model at High Subsonic Speeds. [in the Langley 8 ft transonic tunnel

    NASA Technical Reports Server (NTRS)

    Montoya, L. C.; Flechner, S. G.; Jacobs, P. F.

    1977-01-01

    Pressure and spanwise load distributions on a first-generation jet transport semispan model at high subsonic speeds are presented for the basic wing and for configurations with an upper winglet only, upper and lower winglets, and a simple wing-tip extension. Selected data are discussed to show the general trends and effects of the various configurations.

  6. Modeling the growth and branching of plants: A simple rod-based model

    NASA Astrophysics Data System (ADS)

    Faruk Senan, Nur Adila; O'Reilly, Oliver M.; Tresierras, Timothy N.

    A rod-based model for plant growth and branching is developed in this paper. Specifically, Euler's theory of the elastica is modified to accommodate growth and remodeling. In addition, branching is characterized using a configuration force and evolution equations are postulated for the flexural stiffness and intrinsic curvature. The theory is illustrated with examples of multiple static equilibria of a branched plant and the remodeling and tip growth of a plant stem under gravitational loading.

  7. Preliminary experiments of a single x-ray view catheter 3D localization algorithm for targeted stem cell injections

    NASA Astrophysics Data System (ADS)

    Iovea, M.; Creed, J.; Perin, E.; Neagu, M.; Mateiasi, G.

    2009-02-01

    The aim of this study was to conduct a preliminary check of a new method for measuring the 3D catheter position based on only one X-Ray view (image) and a simple pre-calibration procedure for catheters that could be equipped with high-opacity equal-spaced markers. The application chosen for this experiment is the targeted delivery of cell based therapeutic via a transendocardial retrograde approach into the left ventricle. This approach has shown promising therapeutic retention data when injected directly into the myocardial tissue, but lacks in the ability of the user to confidently manipulate the catheter within the left ventricle cavity space under traditional fluoroscopic guidance using a needle based catheter. The need for a new technique arose from the potential for increased safety and therapeutic efficacy by improving the targeting of the agent. The new technique, destined for Image guided catheter navigation systems for cardiac interventions, is based on a measurement of the marker's size and distance between them and followed by a comparison with the referenced catheter position. Preliminary experiments made with a simple phantom are presented, emphasizing the ability of the new technique in measuring the markers and the catheter tip 3D position. An overall maximum error in positioning markers and catheter tip below 12% has been obtained, yielding a promising result for continuing the future work of improving the algorithm accuracy.

  8. Internet-based early intervention to prevent posttraumatic stress disorder in injury patients: randomized controlled trial.

    PubMed

    Mouthaan, Joanne; Sijbrandij, Marit; de Vries, Giel-Jan; Reitsma, Johannes B; van de Schoot, Rens; Goslings, J Carel; Luitse, Jan S K; Bakker, Fred C; Gersons, Berthold P R; Olff, Miranda

    2013-08-13

    Posttraumatic stress disorder (PTSD) develops in 10-20% of injury patients. We developed a novel, self-guided Internet-based intervention (called Trauma TIPS) based on techniques from cognitive behavioral therapy (CBT) to prevent the onset of PTSD symptoms. To determine whether Trauma TIPS is effective in preventing the onset of PTSD symptoms in injury patients. Adult, level 1 trauma center patients were randomly assigned to receive the fully automated Trauma TIPS Internet intervention (n=151) or to receive no early intervention (n=149). Trauma TIPS consisted of psychoeducation, in vivo exposure, and stress management techniques. Both groups were free to use care as usual (nonprotocolized talks with hospital staff). PTSD symptom severity was assessed at 1, 3, 6, and 12 months post injury with a clinical interview (Clinician-Administered PTSD Scale) by blinded trained interviewers and self-report instrument (Impact of Event Scale-Revised). Secondary outcomes were acute anxiety and arousal (assessed online), self-reported depressive and anxiety symptoms (Hospital Anxiety and Depression Scale), and mental health care utilization. Intervention usage was documented. The mean number of intervention logins was 1.7, SD 2.5, median 1, interquartile range (IQR) 1-2. Thirty-four patients in the intervention group did not log in (22.5%), 63 (41.7%) logged in once, and 54 (35.8%) logged in multiple times (mean 3.6, SD 3.5, median 3, IQR 2-4). On clinician-assessed and self-reported PTSD symptoms, both the intervention and control group showed a significant decrease over time (P<.001) without significant differences in trend. PTSD at 12 months was diagnosed in 4.7% of controls and 4.4% of intervention group patients. There were no group differences on anxiety or depressive symptoms over time. Post hoc analyses using latent growth mixture modeling showed a significant decrease in PTSD symptoms in a subgroup of patients with severe initial symptoms (n=20) (P<.001). Our results do not support the efficacy of the Trauma TIPS Internet-based early intervention in the prevention of PTSD symptoms for an unselected population of injury patients. Moreover, uptake was relatively low since one-fifth of individuals did not log in to the intervention. Future research should therefore focus on innovative strategies to increase intervention usage, for example, adding gameplay, embedding it in a blended care context, and targeting high-risk individuals who are more likely to benefit from the intervention. International Standard Randomized Controlled Trial Number (ISRCTN): 57754429; http://www.controlled-trials.com/ISRCTN57754429 (Archived by WebCite at http://webcitation.org/6FeJtJJyD).

  9. Attosecond control of electrons emitted from a nanoscale metal tip.

    PubMed

    Krüger, Michael; Schenk, Markus; Hommelhoff, Peter

    2011-07-06

    Attosecond science is based on steering electrons with the electric field of well controlled femtosecond laser pulses. It has led to the generation of extreme-ultraviolet pulses with a duration of less than 100 attoseconds (ref. 3; 1 as = 10(-18) s), to the measurement of intramolecular dynamics (by diffraction of an electron taken from the molecule under scrutiny) and to ultrafast electron holography. All these effects have been observed with atoms or molecules in the gas phase. Electrons liberated from solids by few-cycle laser pulses are also predicted to show a strong light-phase sensitivity, but only very small effects have been observed. Here we report that the spectra of electrons undergoing photoemission from a nanometre-scale tungsten tip show a dependence on the carrier-envelope phase of the laser, with a current modulation of up to 100 per cent. Depending on the carrier-envelope phase, electrons are emitted either from a single sub-500-attosecond interval of the 6-femtosecond laser pulse, or from two such intervals; the latter case leads to spectral interference. We also show that coherent elastic re-scattering of liberated electrons takes place at the metal surface. Owing to field enhancement at the tip, a simple laser oscillator reaches the peak electric field strengths required for attosecond experiments at 100-megahertz repetition rates, rendering complex amplified laser systems dispensable. Practically, this work represents a simple, extremely sensitive carrier-envelope phase sensor, which could be shrunk in volume to about one cubic centimetre. Our results indicate that the attosecond techniques developed with (and for) atoms and molecules can also be used with solids. In particular, we foresee subfemtosecond, subnanometre probing of collective electron dynamics (such as plasmon polaritons) in solid-state systems ranging in scale from mesoscopic solids to clusters and to single protruding atoms. ©2011 Macmillan Publishers Limited. All rights reserved

  10. Behavior of Triple Langmuir Probes in Non-Equilibrium Plasmas

    NASA Technical Reports Server (NTRS)

    Polzin, Kurt A.; Ratcliffe, Alicia C.

    2018-01-01

    The triple Langmuir probe is an electrostatic probe in which three probe tips collect current when inserted into a plasma. The triple probe differs from a simple single Langmuir probe in the nature of the voltage applied to the probe tips. In the single probe, a swept voltage is applied to the probe tip to acquire a waveform showing the collected current as a function of applied voltage (I-V curve). In a triple probe three probe tips are electrically coupled to each other with constant voltages applied between each of the tips. The voltages are selected such that they would represent three points on the single Langmuir probe I-V curve. Elimination of the voltage sweep makes it possible to measure time-varying plasma properties in transient plasmas. Under the assumption of a Maxwellian plasma, one can determine the time-varying plasma temperature T(sub e)(t) and number density n(sub e)(t) from the applied voltage levels and the time-histories of the collected currents. In the present paper we examine the theory of triple probe operation, specifically focusing on the assumption of a Maxwellian plasma. Triple probe measurements have been widely employed for a number of pulsed and timevarying plasmas, including pulsed plasma thrusters (PPTs), dense plasma focus devices, plasma flows, and fusion experiments. While the equilibrium assumption may be justified for some applications, it is unlikely that it is fully justifiable for all pulsed and time-varying plasmas or for all times during the pulse of a plasma device. To examine a simple non-equilibrium plasma case, we return to basic governing equations of probe current collection and compute the current to the probes for a distribution function consisting of two Maxwellian distributions with different temperatures (the two-temperature Maxwellian). A variation of this method is also employed, where one of the Maxwellians is offset from zero (in velocity space) to add a suprathermal beam of electrons to the tail of the main Maxwellian distribution (the bump-on-the-tail distribution function). For a range of parameters in these non-Maxwellian distributions, we compute the current collection to the probes. We compare the distribution function that was assumed a priori with the distribution function one would infer when applying standard triple probe theory to analyze the collected currents. For the assumed class of non-Maxwellian distribution functions this serves to illustrate the effect a non-Maxwellian plasma would have on results interpreted using the equilibrium triple probe current collection theory, allowing us to state the magnitudes of these deviations as a function of the assumed distribution function properties.

  11. A T-shape linear piezoelectric motor with single foot.

    PubMed

    Liu, Yingxiang; Chen, Weishan; Yang, Xiaohui; Liu, Junkao

    2015-02-01

    A new T-shape piezoelectric motor using the hybrid of two orthogonal longitudinal vibrations is proposed in this work. Six pieces of PZT ceramic plates are bonded on the upside and downside surfaces of a T-shape duralumin alloy base respectively to form the proposed motor. Elliptical movement can be generated on the driving tip by applying sine and cosine voltages to the PZT elements. The horizontal displacement of the driving tip will push the runner while the vertical displacement can overcome the preload. Finite element method is used to accomplish the design and analysis process. The resonance frequencies of the two vibration modes are tuned to be close by modal analysis, while the motion trajectory of the driving tip is observed by transient analysis. After the fabrication of a prototype, the vibration characteristics and mechanical output ability are measured. The no-load speed and the maximum output thrust force of the proposed motor are tested to be 718 mm/s and 3.5 N under an exciting frequency of 53.1 kHz. The proposed T-shape piezoelectric motor exhibits merits of simple structure, easy to realize miniaturization, easy to be fabricated, and high power-to-weight ratio. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Dynamic characteristics of pulsed supersonic fuel sprays

    NASA Astrophysics Data System (ADS)

    Pianthong, K.; Matthujak, A.; Takayama, K.; Milton, B. E.; Behnia, M.

    2008-06-01

    This paper describes the dynamic characteristics of pulsed, supersonic liquid fuel sprays or jets injected into ambient air. Simple, single hole nozzles were employed with the nozzle sac geometries being varied. Different fuel types, diesel fuel, bio-diesel, kerosene, and gasoline were used to determine the effects of fuel properties on the spray characteristics. A vertical two-stage light gas gun was employed as a projectile launcher to provide a high velocity impact to produce the liquid jet. The injection pressure was around 0.88-1.24 GPa in all cases. The pulsed, supersonic fuel sprays were visualized by using a high-speed video camera and shadowgraph method. The spray tip penetration and velocity attenuation and other characteristics were examined and are described here. An instantaneous spray tip velocity of 1,542 m/s (Mach number 4.52) was obtained. However, this spray tip velocity can be sustained for only a very short period (a few microseconds). It then attenuates very quickly. The phenomenon of multiple high frequency spray pulses generated by a single shot impact and the changed in the angle of the shock structure during the spray flight, which had already been observed in previous studies, is again noted. Multiple shock waves from the conical nozzle spray were also clearly captured.

  13. Novel synthetic lethality screening method identifies TIP60-dependent radiation sensitivity in the absence of BAF180.

    PubMed

    Hopkins, Suzanna R; McGregor, Grant A; Murray, Johanne M; Downs, Jessica A; Savic, Velibor

    2016-10-01

    In recent years, research into synthetic lethality and how it can be exploited in cancer treatments has emerged as major focus in cancer research. However, the lack of a simple to use, sensitive and standardised assay to test for synthetic interactions has been slowing the efforts. Here we present a novel approach to synthetic lethality screening based on co-culturing two syngeneic cell lines containing individual fluorescent tags. By associating shRNAs for a target gene or control to individual fluorescence labels, we can easily follow individual cell fates upon siRNA treatment and high content imaging. We have demonstrated that the system can recapitulate the functional defects of the target gene depletion and is capable of discovering novel synthetic interactors and phenotypes. In a trial screen, we show that TIP60 exhibits synthetic lethality interaction with BAF180, and that in the absence of TIP60, there is an increase micronuclei dependent on the level of BAF180 loss, significantly above levels seen with BAF180 present. Moreover, the severity of the interactions correlates with proxy measurements of BAF180 knockdown efficacy, which may expand its usefulness to addressing synthetic interactions through titratable hypomorphic gene expression. Copyright © 2016. Published by Elsevier B.V.

  14. Thermally dried ink-jet process for 6,13-bis(triisopropylsilylethynyl)-pentacene for high mobility and high uniformity on a large area substrate

    USGS Publications Warehouse

    Ryu, Gi Seong; Lee, Myung Won; Jeong, Seung Hyeon; Song, Chung Kun

    2012-01-01

    In this study we developed a simple ink-jet process for 6,13-bis(triisopropylsilylethynyl)-pentacene (TIPS-pentacene), which is known as a high-mobility soluble organic semiconductor, to achieve relatively high-mobility and high-uniformity performance for large-area applications. We analyzed the behavior of fluorescent particles in droplets and applied the results to determining a method of controlling the behavior of TIPS-pentacene molecules. The grain morphology of TIPS-pentacene varied depending on the temperature applied to the droplets during drying. We were able to obtain large and uniform grains at 46 degrees C without any "coffee stain". The process was applied to a large-size organic thin-film transistor (OTFT) backplane for an electrophoretic display panel containing 192 x 150 pixels on a 6-in.-sized substrate. The average of mobilities of 36 OTFTs, which were taken from different locations of the backplane, was 0.44 +/- 0.08 cm2.V-1.s-1, with a small deviation of 20%, over a 6-in.-size area comprising 28,800 OTFTs. This process providing high mobility and high uniformity can be achieved by simply maintaining the whole area of the substrate at a specific temperature (46 degrees C in this case) during drying of the droplets.

  15. Assessment of arsenic toxicity using Allium/Vicia root tip micronucleus assays.

    PubMed

    Wu, Lihua; Yi, Huilan; Yi, Min

    2010-04-15

    Arsenic is ubiquitous in the environment and is a potential human carcinogen. Its carcinogenicity has been demonstrated in several models. In this study, broad bean (Vicia faba L.) and common onion (Allium cepa L.), two plant species which are commonly used for detecting the genotoxic effects of environmental pollutants, were used to measure possible genotoxic effect of arsenite (0.3-30 mg/l). Present results showed that arsenite (As(III)) induced micronuclei (MN) formation in both Allium and Vicia root tips. MN frequency significantly increased in Vicia root cells exposed to 0.3-10 mg/l arsenite and in Allium root cells exposed to 1-30 mg/l arsenite, which indicated that Vicia root tip cells are more sensitive to arsenite than Allium. Mitotic index (MI) decreased in a concentration-dependent manner and showed significant differences in Vicia/Allium roots among treatments and the control, after exposure to 1-30 mg/l arsenite for at least 4 h. In the present study, MN frequency was positively associated with lipid peroxidation, which indicated that arsenite exposure can induce oxidative stress, cytotoxicity and genotoxicity in plant cells. The results also suggested that Vicia/Allium root micronucleus (MN) assays are simple, efficient and reproducible methods for the genotoxicity monitoring of arsenic water contamination. 2009 Elsevier B.V. All rights reserved.

  16. Life, Living, and Learning in the Teen Years.

    ERIC Educational Resources Information Center

    Wisconsin State Dept. of Public Instruction, Madison.

    This packet contains articles by and for teenagers and articles and tips sheets for educators and parents. Included are: (1) "What Teens Need from Teachers, Parents, and Other Adults" (Stephen Small); (2) "Visually Impaired, Deaf Teens Share Views"; (3) "Teens Benefit from Community Service" (Kelli Krueger); (4) "My Experience in Foster Care;" (5)…

  17. Tips for Reading Tutors = Consejos para los Tutores en Lectura.

    ERIC Educational Resources Information Center

    Department of Education, Washington, DC.

    Reading is the basis for learning and school success. While reading is learned primarily in the classroom, many students need extra time and help. Research shows that tutoring is a great way for individuals and groups outside school to support learning, but effective tutoring requires appropriate training and careful planning. This brochure,…

  18. Portfolio Preparation Tips for Teachers

    ERIC Educational Resources Information Center

    Hunter-Lombardi, Brooke

    2008-01-01

    As college deadlines loom, teachers may wonder if there is a magic portfolio formula for their students to follow. After twenty years of thought on portfolio development and the opportunity to review over 10,000 individual portfolios, the author is convinced that there is no single formula for success. With hard work, careful planning, and…

  19. Breast Cancer Screening in a Low Income Managed Care Populaton

    DTIC Science & Technology

    1999-10-01

    early to know for sure if these things affect breast cancer risk. can help prevent heart disease and osteoporosis after menopause. .,.- Experts generally...firmly in small massaging motions with the pads of your fingers (not the tips). Don’t forget the area in your armpit. Gently squeeze the nipple. Switch

  20. School-Age NOTES, 1999.

    ERIC Educational Resources Information Center

    Scofield, Richard T., Ed.

    1999-01-01

    This document is comprised of the 12 monthly issues of a newsletter providing support and information for providers of child care for school-age children. The featured articles for each month are: (1) "Tips for New and Old for the New School Year" (September); (2) "Train Them and Retain Them: Keeping Quality Staff" (October); (3) "What Older Kids…

  1. On the three-dimensional interaction of a rotor-tip vortex with a cylindrical surface

    NASA Astrophysics Data System (ADS)

    Radcliff, Thomas D.; Burggraf, Odus R.; Conlisk, A. T.

    2000-12-01

    The collision of a strong vortex with a surface is an important problem because significant impulsive loads may be generated. Prediction of helicopter fatigue lifetime may be limited by an inability to predict these loads accurately. Experimental results for the impingement of a helicopter rotor-tip vortex on a cylindrical airframe show a suction peak on the top of the airframe that strengthens and then weakens within milliseconds. A simple line-vortex model can predict the experimental results if the vortex is at least two vortex-core radii away from the airframe. After this, the model predicts continually deepening rather than lessening suction as the vortex stretches. Experimental results suggest that axial flow within the core of a tip vortex has an impact on the airframe pressure distribution upon close approach. The mechanism for this is hypothesized to be the inviscid redistribution of the vorticity field within the vortex as the axial velocity stagnates. Two models of a tip vortex with axial flow are considered. First, a classical axisymmetric line vortex with a cutoff parameter is superimposed with vortex ringlets suitably placed to represent the helically wound vortex shed by the rotor tip. Thus, inclusion of axial flow is found to advect vortex core thinning away from the point of closest interaction as the vortex stretches around the cylindrical surface during the collision process. With less local thinning, vorticity in the cutoff parameter model significantly overlaps the solid cylinder in an unphysical manner, highlighting the fact that the vortex core must deform from its original cylindrical shape. A second model is then developed in which axial and azimuthal vorticity are confined within a rectangular-section vortex. Area and aspect ratio of this vortex can be varied independently to simulate deformation of the vortex core. Both axial velocity and core deformation are shown to be important to calculate the local induced pressure loads properly. The computational results are compared with experiments conducted at the Georgia Institute of Technology.

  2. Charge injection in thin dielectric layers by atomic force microscopy: influence of geometry and material work function of the AFM tip on the injection process

    NASA Astrophysics Data System (ADS)

    Villeneuve-Faure, C.; Makasheva, K.; Boudou, L.; Teyssedre, G.

    2016-06-01

    Charge injection and retention in thin dielectric layers remain critical issues for the reliability of many electronic devices because of their association with a large number of failure mechanisms. To overcome this drawback, a deep understanding of the mechanisms leading to charge injection close to the injection area is needed. Even though the charge injection is extensively studied and reported in the literature to characterize the charge storage capability of dielectric materials, questions about charge injection mechanisms when using atomic force microscopy (AFM) remain open. In this paper, a thorough study of charge injection by using AFM in thin plasma-processed amorphous silicon oxynitride layers with properties close to that of thermal silica layers is presented. The study considers the impact of applied voltage polarity, work function of the AFM tip coating and tip curvature radius. A simple theoretical model was developed and used to analyze the obtained experimental results. The electric field distribution is computed as a function of tip geometry. The obtained experimental results highlight that after injection in the dielectric layer the charge lateral spreading is mainly controlled by the radial electric field component independently of the carrier polarity. The injected charge density is influenced by the nature of electrode metal coating (work function) and its geometry (tip curvature radius). The electron injection is mainly ruled by the Schottky injection barrier through the field electron emission mechanism enhanced by thermionic electron emission. The hole injection mechanism seems to differ from the electron one depending on the work function of the metal coating. Based on the performed analysis, it is suggested that for hole injection by AFM, pinning of the metal Fermi level with the metal-induced gap states in the studied silicon oxynitride layers starts playing a role in the injection mechanisms.

  3. Is traditional reading of the bedside chest radiograph appropriate to detect intraatrial central venous catheter position?

    PubMed

    Wirsing, Melanie; Schummer, Claudia; Neumann, Rotraud; Steenbeck, Jörg; Schmidt, Peter; Schummer, Wolfram

    2008-09-01

    Traditionally, the positioning of central venous catheters (CVCs) outside the right atrium (RA) in patients receiving intensive care is determined by surrogate landmarks on bedside chest radiographs (CXRs). The validity of this method was examined by comparing readings of radiologists with the results of transesophageal echocardiography (TEE). Prospective study at university hospital. Two hundred thirteen adults scheduled for cardiothoracic surgery were randomized to right or left internal jugular vein catheterization under ECG guidance. One senior radiologist and two radiologists in training independently read the CXRs, and determined whether the CVC tip ended in the RA and measured the vertical distance from the CVC tip to the carina (TC-distance). Two hundred twelve CVC tips could be identified by TEE. Only left-sided CVCs (n = 5) ended in the upper RA (2.4%). Three of those patients were shorter than 160 cm. Specificity was 94% for senior radiologist, 44% for the first radiologist in training, and 60% for the second radiologist in training. The TC-distance of intraatrial catheters was 39, 55, 59, 80, and 83 mm, respectively. Thus, a TC-distance < or = 55 mm ensured extraatrial tip position in four of five intraatrial CVCs (80%, p = 0.002). The TC-distance of extraatrial catheters ranged from - 26 to 102 mm. Reading of a bedside CXR alone is not very accurate to identify intraatrial CVC tip position. TC-distance is a helpful marker, and its specificity is as good as that of an experienced radiologist if a cutoff value of 55 mm is chosen.

  4. Twelve tips for teaching child development and disability to medical students.

    PubMed

    McDonald, Jenny

    2018-02-01

    Child development is a marker of well-being in childhood and recognition of developmental delay allows timely investigation and intervention for children with developmental disabilities. Despite this, child development and disabilities are not given emphasis in the medical curriculum. This under representation of teaching combined with the stigma associated with disabilities contributes to the sub-optimal health care of people with disabilities. As well as, addressing the stigma of disability a medical undergraduate curriculum should include: the key concepts of child development; the clinical presentation of the most common developmental disabilities; developmental history taking and the infant neurodevelopmental examination. The following twelve tips provide practical advice about how to teach this knowledge and these skills during medical training.

  5. Rotation Conversation: A Tip on How To Organize a Conversation Class; Amazing Sentences of Indian Students: A Simple Writing Activity that Triggered Profound Ideas; "Short and Sweet" in a Thai Classroom (A Lesson Plan Based on a Mini Literacy Text); A Pile of Pictures: Ten Practical Ideas for Your Classroom.

    ERIC Educational Resources Information Center

    Singleton, Pat; Dhanavel, P.; Lwin, Phyu Phyu; Yoel, Judith

    2002-01-01

    Techniques for teaching in the English-as-a-Second/Foreign-Language classroom are included. They focus on planning a conversation class, teaching writing, a lesson plan based on a multiliteracy text, and how a pile of pictures can be used in different ways. (Author/VWL)

  6. A Monograph of Papuan Psychodidae, Including Phlebotomus (Diptera)

    DTIC Science & Technology

    1967-10-10

    176. aponesos Quale 177. spinacia n. sp. 178. echinata n. sp. 179. veses n. sp. 𔃺:;&040.;1$. 180. concinna n. sp. 181. hastata n. sp. 182. serpentina ...fig. 81f. 182. serpentina 59 (44). Aedeagus simple, composed only of main shaft 60 Aedeagus bipartite, compost.’<i of main and lateral shafts 62 60 (59...paramere composed of pair of slender, setose lobes 182. serpentina 65 (64). Lateral shaft of aedeagus extends to tip of main shaft; dististyle longer

  7. Crack Growth of a Titanium-Aluminide Alloy under Thermal-Mechanical Fatigue

    DTIC Science & Technology

    1988-12-01

    the elastic-plastic fracture mechanics ( EPFM ) relations such as the J-integral or crack tip opening displacement (CTOD) must be used. Much more work...has been done in the area of LEFM, using stress intensity factor range AK as a correlating factor, than in EPFM . No matter which type of analysis is...thus obvious that a simple linear summation model such as Heil’s might not be applicable to this material. Other damage mechanisms were then investigated

  8. Back to the kitchen: food-grade agar is a low-cost alternative to bacteriological agar.

    PubMed

    Petrovski, Steve; Tillett, Daniel

    2012-10-15

    Food-grade agar can be used as a low-cost substitute for bacteriological agar in the preparation of solid microbial media. No difference was observed in the colony morphology, growth rate, or viability of bacteria grown on solid media prepared using food-grade agar as compared with using bacteriological-grade agar. This simple tip can reduce the cost of the most common solid media by 80% or more. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Effect of winglets on a first-generation jet transport wing. 3: Pressure and spanwise load distributions for a semispan model at Mach 0.30. [in the Langley 8 ft transonic tunnel

    NASA Technical Reports Server (NTRS)

    Montoya, L. C.; Jacobs, P. F.; Flechner, S. G.

    1977-01-01

    Pressure and spanwise load distributions on a first-generation jet transport semispan model at a Mach number of 0.30 are given for the basic wing and for configurations with an upper winglet only, upper and lower winglets, and a simple wing-tip extension. To simulate second-segment-climb lift conditions, leading- and/or trailing-edge flaps were added to some configurations.

  10. Comparison of electro and chemical cautery in the treatment of anterior epistaxis.

    PubMed

    Toner, J G; Walby, A P

    1990-08-01

    In the ENT Department of the Royal Victoria Hospital, Belfast, the impression (supported only by anecdotes) was that electro-cautery was superior to chemical cautery in the treatment of simple anterior epistaxis. Since no evaluation of the relative merits of electro and chemical cautery has been reported, a prospective randomized study was conducted to assess the effectiveness of electro-cautery and cautery with silver nitrate. The results of the study showed that there was no statistically significant difference between the two methods in either controlling the epistaxis or in the incidence of complications. It is concluded that since cautery with a silver nitrate tipped applicator is simpler, and of equal effectiveness, it would appear to be the treatment of choice for simple anterior epistaxis.

  11. Technical tips during implantation of selective upper airway stimulation.

    PubMed

    Heiser, Clemens; Thaler, Erica; Soose, Ryan J; Woodson, B Tucker; Boon, Maurits

    2018-03-01

    Selective upper airway stimulation is now well-established in the United States and in several European countries, with more than 1,000 patients implanted since U.S. Food and Drug Administration approval in April 2014. The authors herein, all head and neck surgeons, account for approximately one of every five implants completed to date. Several of the authors also provide comprehensive longitudinal care of their patients as dual-specialty sleep medicine physicians. Multi-center, retrospective clinical analysis. More than 300 implants have been evaluated and reviewed in five different implant centers (Germany, United States). This analysis shares tips and techniques from the collective experiences with more than 300 implants, which can help newer implanters learn vicariously both for standard practices in executing routine implants through activation and, importantly, for working through more challenging encounters with anatomy, special patient phenotypes, system testing, and troubleshooting. These tips should help new implanters handle most of the situations arising during implantation and avoid common pitfalls. Laryngoscope, 128:756-762, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  12. Caring for yourself during times of organizational change.

    PubMed

    Cook, C A; Buck, E A

    1999-09-01

    Mergers, acquisitions, and other organizational changes in the health care system pose many challenges and stresses for nursing leaders. Although considerable effort is expended helping staff adjust to change, nurse managers and executives often neglect their own vulnerability to occupational stress. The personal and organizational costs of managerial burnout are high, sometimes resulting in physical illness, mental exhaustion, and decreased productivity. This article emphasizes the importance of prevention through the recognition of potential or actual signs of organizational stress. Handy tips are provided on effective ways to cope with the stress of organizational change.

  13. How to Manage Hospital-Based Palliative Care Teams Without Full-Time Palliative Care Physicians in Designated Cancer Care Hospitals: A Qualitative Study.

    PubMed

    Sakashita, Akihiro; Kishino, Megumi; Nakazawa, Yoko; Yotani, Nobuyuki; Yamaguchi, Takashi; Kizawa, Yoshiyuki

    2016-07-01

    To clarify how highly active hospital palliative care teams can provide efficient and effective care regardless of the lack of full-time palliative care physicians. Semistructured focus group interviews were conducted, and content analysis was performed. A total of 7 physicians and 6 nurses participated. We extracted 209 codes from the transcripts and organized them into 3 themes and 21 categories, which were classified as follows: (1) tips for managing palliative care teams efficiently and effectively (7 categories); (2) ways of acquiring specialist palliative care expertise (9 categories); and (3) ways of treating symptoms that are difficult to alleviate (5 categories). The findings of this study can be used as a nautical chart of hospital-based palliative care team (HPCT) without full-time PC physician. Full-time nurses who have high management and coordination abilities play a central role in resource-limited HPCTs. © The Author(s) 2015.

  14. A radiographic investigation to determine the safety of suture anchor systems for pediatric modified Broström ankle ligament reconstruction.

    PubMed

    Hazratwala, Kaushik; Best, Alistair; Kopplin, Matthew; Giza, Eric; Sullivan, Martin

    2005-03-01

    The modified Broström ligament reconstruction using anchor sutures has been performed in adults with clinical success; however, the safety parameters for the use of suture anchors in adolescent lateral ankle ligament reconstruction have not been established. To perform a radiographic analysis comparing the depth of penetration of suture anchors in adult ankle ligament reconstruction with the average distance of the physis from the tip of the fibula in adolescents. Cross-sectional study, Level of evidence, 4. Forty postoperative ankle radiographs of adult patients who had a modified Broström procedure were compared with 40 normal adolescent ankle radiographs. In the adult group, the distance of the suture anchor penetration from the distal tip of the fibula was measured; in the adolescent group, the distance of the physis from the distal tip of the fibula was measured. The mean depth of the suture anchors was 17 mm (range, 14-21 mm) from the tip of the fibula in the adult group, and the mean distance of the growth plate was 23 mm (range, 18-29 mm) in the adolescent group. Eight radiographs from the adolescent group (20%) had a physis measurement of <22 mm on the anteroposterior or mortise view. Using careful preoperative planning and intraoperative technique, it is possible to safely perform lateral ankle ligament repair in the skeletally immature patient using suture anchors.

  15. Gestational Exposure to the Synthetic Cathinone Methylenedioxypyrovalerone Results in Reduced Maternal Care and Behavioral Alterations in Mouse Pups

    PubMed Central

    Gerecsei, László I.; Csillag, András; Zachar, Gergely; Gévai, Lőrinc; Simon, László; Dobolyi, Árpád; Ádám, Ágota

    2018-01-01

    The member of synthetic cathinone family, methylenedioxypyrovalerone (MDPV), is a frequently used psychoactive drug of abuse. The objective of our study was to determine the effect of MDPV (administered from the 8th to the 14th day of gestation) on the behavior of neonatal and adolescent mice, as well as its effect on maternal care. We measured maternal care (pup retrieval test, nest building), locomotor activity (open field test), and motor coordination (grip strength test) of dams, whereas on pups we examined locomotor activity at postnatal day 7 and day 21 (open field test) and motor coordination on day 21 (grip strength test). On fresh-frozen brain samples of the dams we examined the expression of two important peptides implicated in the regulation of maternal behavior and lactation: tuberoinfundibular peptide 39 (TIP39) mRNA in the thalamic posterior intralaminar complex, and amylin mRNA in the medial preoptic nucleus. We detected decreased birth rate and survival of offspring, and reduced maternal care in the drug-treated animals, whereas there was no difference between the motility of treated and control mothers. Locomotor activity of the pups was increased in the MDPV treated group both at 7 and 21 days of age, while motor coordination was unaffected by MDPV treatment. TIP39 and amylin were detected in their typical location but failed to show a significant difference of expression between the drug-treated and control groups. The results suggest that chronic systemic administration of the cathinone agent MDPV to pregnant mice can reduce birth rate and maternal care, and it also enhances motility (without impairment of motor coordination) of the offspring. PMID:29459818

  16. Backed Bending Actuator

    NASA Technical Reports Server (NTRS)

    Costen, Robert C.; Su, Ji

    2004-01-01

    Bending actuators of a proposed type would partly resemble ordinary bending actuators, but would include simple additional components that would render them capable of exerting large forces at small displacements. Like an ordinary bending actuator, an actuator according to the proposal would include a thin rectangular strip that would comprise two bonded layers (possibly made of electroactive polymers with surface electrodes) and would be clamped at one end in the manner of a cantilever beam. Unlike an ordinary bending actuator, the proposed device would include a rigid flat backplate that would support part of the bending strip against backward displacement; because of this feature, the proposed device is called a backed bending actuator. When an ordinary bending actuator is inactive, the strip typically lies flat, the tip displacement is zero, and the force exerted by the tip is zero. During activation, the tip exerts a transverse force and undergoes a bending displacement that results from the expansion or contraction of one or more of the bonded layers. The tip force of an ordinary bending actuator is inversely proportional to its length; hence, a long actuator tends to be weak. The figure depicts an ordinary bending actuator and the corresponding backed bending actuator. The bending, the tip displacement (d(sub t)), and the tip force (F) exerted by the ordinary bending actuator are well approximated by the conventional equations for the loading and deflection of a cantilever beam subject to a bending moment which, in this case, is applied by the differential expansion or contraction of the bonded layers. The bending, displacement, and tip force of the backed bending actuator are calculated similarly, except that it is necessary to account for the fact that the force F(sub b) that resists the displacement of the tip could be sufficient to push part of the strip against the backplate; in such a condition, the cantilever beam would be effectively shortened (length L*) and thereby stiffened and, hence, made capable of exerting a greater tip force for a given degree of differential expansion or contraction of the bonded layers. Taking all of these effects into account, the cantilever-beam equations show that F(sub b) would be approximately inversely proportional to d(sup 1/2) for d less than a calculable amount, denoted the transition displacement (dt). For d less than d(sub t), part of the strip would be pressed against the backplate. Therefore, the force F(sub b) would be very large for d at or near zero and would decrease as d increases toward d(sub t). At d greater than d(sub t), none of the strip would be pressed against the backplate and F(sub b) would equal the tip force F of the corresponding ordinary bending actuator. The advantage of the proposal is that a backed bending actuator could be made long to obtain large displacement when it encountered little resistance but it could also exert a large zero-displacement force, so that it could more easily start the movement of a large mass, throw a mechanical switch, or release a stuck mechanism.

  17. [Trauma-Informed Peer Counselling in the Care of Refugees with Trauma-Related Disorders].

    PubMed

    Wöller, Wolfgang

    2016-09-01

    Providing adequate culture-sensitive care for a large number of refugees with trauma-related disorders constitutes a major challenge. In this context, peer support and trauma-informed peer counselling can be regarded as a valuable means to complement the psychosocial care systems. In recent years, peer support and peer education have been successfully implemented e. g. in health care education, in psychiatric care, and in the treatment of traumatized individuals. Only little research data is available for traumatized refugees. However, results are encouraging. A program is presented which integrates trauma-informed peer educators (TIP) with migration background in the care of traumatized refugees. Peers' responsibility includes emotional support and understanding the refugees' needs, sensitizing for trauma-related disorders, providing psychoeducation, and teaching trauma-specific stabilization techniques under supervision of professional psychotherapists. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Multicultural Nursing: Providing Better Employee Care.

    PubMed

    Rittle, Chad

    2015-12-01

    Living in an increasingly multicultural society, nurses are regularly required to care for employees from a variety of cultural backgrounds. An awareness of cultural differences focuses occupational health nurses on those differences and results in better employee care. This article explores the concept of culturally competent employee care, some of the non-verbal communication cues among cultural groups, models associated with completing a cultural assessment, and how health disparities in the workplace can affect delivery of employee care. Self-evaluation of the occupational health nurse for personal preferences and biases is also discussed. Development of cultural competency is a process, and occupational health nurses must develop these skills. By developing cultural competence, occupational health nurses can conduct complete cultural assessments, facilitate better communication with employees from a variety of cultural backgrounds, and improve employee health and compliance with care regimens. Tips and guidelines for facilitating communication between occupational health nurses and employees are also provided. © 2015 The Author(s).

  19. Using Current Resources to Implement Wellness Programming for Preschoolers

    ERIC Educational Resources Information Center

    Cirignano, Sherri M.

    2013-01-01

    Currently, there is a nationwide effort to include preschool-aged children in wellness efforts for the prevention of obesity. National resources include guidelines, best practices, and tip sheets to assist in the implementation of these interventions. The Let's Move! Child Care Checklist is a resource that can be used to assess the level at…

  20. Teaching Concepts to Young Children Through Cultural Cooking Experiences. Bilingual/Bicultural Child Development Associate Pilot Project: Module XIV.

    ERIC Educational Resources Information Center

    Smith, Teresa R.

    This Child Development Associate (CDA) module, the fourteenth in a series of 16, suggests ways concepts can be taught by involving preschool children in carefully planned classroom cooking activities. Designed for bilingual/bicultural preschool teacher trainees, the module provides tips on food preparation as a learning experience. Required…

  1. Try to Be Complete on Something: Tips on Building a Highly Specialized Subject Collection

    ERIC Educational Resources Information Center

    Bottorff, Tim

    2011-01-01

    Wise and careful selection of materials remains among the most important and enduring duties of the librarian--and also among the most difficult. The author has found this to be especially true in a specialized-subject library, where traditional collection development methods do not always yield good results. While collection development practices…

  2. AUTOMOTIVE DIESEL MAINTENANCE 1. UNIT IV, MAINTAINING THE COOLING SYSTEM--DETROIT DIESEL ENGINES.

    ERIC Educational Resources Information Center

    Human Engineering Inst., Cleveland, OH.

    THIS MODULE OF A 30-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE OPERATION AND MAINTENANCE OF THE DIESEL ENGINE COOLING SYSTEM. TOPICS ARE PURPOSE OF THE COOLING SYSTEM, CARE MAINTENANCE OF THE COOLING SYSTEM, COOLING SYSTEM COMPONENTS, AND TROUBLESHOOTING TIPS. THE MODULE CONSISTS OF A SELF-INSTRUCTIONAL BRANCH PROGRAMED TRAINING…

  3. The Caring Teacher: Tips to Motivate Student Learning

    ERIC Educational Resources Information Center

    Johnson, L. Peter

    2008-01-01

    The most successful educators know that there are two components to teaching: the academic side and the human side. Contrary to what most people think, the human aspect of teaching is by far the most difficult to achieve. Teachers are expected to relate to and educate a wide range of personalities, levels of maturity, and emotions. It is very…

  4. Critical Care Coding for Neurologists.

    PubMed

    Nuwer, Marc R; Vespa, Paul M

    2015-10-01

    Accurate coding is an important function of neurologic practice. This contribution to Continuum is part of an ongoing series that presents helpful coding information along with examples related to the issue topic. Tips for diagnosis coding, Evaluation and Management coding, procedure coding, or a combination are presented, depending on which is most applicable to the subject area of the issue.

  5. Living in Spain. A Brief Introduction or Review of the Culture and Language of Spain for Visitors, Students, and Business Travelers. First Edition.

    ERIC Educational Resources Information Center

    Fantini, Alvino E.; Enriquez A., Cristina

    The guide offers practical information on various aspects of daily living, including: money; banks; food; restaurants; hotels; tipping; postal and telecommunications services; transportation; shopping; health and medical care; safety and security; electricity; measurement and clothing size conversions; greetings and leave-takings; titles and forms…

  6. Best Wishes for a Peaceful Classroom

    ERIC Educational Resources Information Center

    Childhood Education, 2005

    2005-01-01

    Every teacher has one particular wish, and it is usually for a peaceful classroom. This article features several tips for educators on how to have a peaceful classroom. They should plan carefully for their first week. They should write out half-hour segments of what they wish to accomplish. They should introduce a Peace Table, set up near their…

  7. Stress-intensity factors for a thick-walled cylinder containing an annular imbedded or external or internal surface crack

    NASA Technical Reports Server (NTRS)

    Erdol, R.; Erdogan, F.

    1976-01-01

    The elastostatic axisymmetric problem for a long thick-walled cylinder containing a ring-shaped internal or edge crack is considered. Using the standard transform technique the problem is formulated in terms of an integral equation which has a simple Cauchy kernel for the internal crack and a generalized Cauchy kernel for the edge crack as the dominant part. As examples the uniform axial load and the steady-state thermal stress problems have been solved and the related stress intensity factors have been calculated. Among other findings the results show that in the cylinder under uniform axial stress containing an internal crack the stress intensity factor at the inner tip is always greater than that at the outer tip for equal net ligament thicknesses and in the cylinder with an edge crack which is under a state of thermal stress the stress intensity factor is a decreasing function of the crack depth, tending to zero as the crack depth approaches the wall thickness.

  8. Building a flagellum in biological outer space.

    PubMed

    Evans, Lewis D B; Hughes, Colin; Fraser, Gillian M

    2014-02-01

    Flagella, the rotary propellers on the surface of bacteria, present a paradigm for how cells build and operate complex molecular 'nanomachines'. Flagella grow at a constant rate to extend several times the length of the cell, and this is achieved by thousands of secreted structural subunits transiting through a central channel in the lengthening flagellum to incorporate into the nascent structure at the distant extending tip. A great mystery has been how flagella can assemble far outside the cell where there is no conventional energy supply to fuel their growth. Recent work published by Evans et al. [ Nature (2013) 504: 287-290], has gone some way towards solving this puzzle, presenting a simple and elegant transit mechanism in which growth is powered by the subunits them selves as they link head-to-tail in a chain that is pulled through the length of the growing structure to the tip. This new mechanism answers an old question and may have resonance in other assembly processes.

  9. Tipping Points, Great and Small

    NASA Astrophysics Data System (ADS)

    Morrison, Foster

    2010-12-01

    The Forum by Jordan et al. [2010] addressed environmental problems of various scales in great detail, but getting the critical message through to the formulators of public policies requires going back to basics, namely, that exponential growth (of a population, an economy, or most anything else) is not sustainable. When have you heard any politician or economist from anywhere across the ideological spectrum say anything other than that more growth is essential? There is no need for computer models to demonstrate “limits to growth,” as was done in the 1960s. Of course, as one seeks more details, the complexity of modeling will rapidly outstrip the capabilities of both observation and computing. This is common with nonlinear systems, even simple ones. Thus, identifying all possible “tipping points,” as suggested by Jordan et al. [2010], and then stopping just short of them, is impractical if not impossible. The main thing needed to avoid environmental disasters is a bit of common sense.

  10. Filopodia Conduct Target Selection in Cortical Neurons Using Differences in Signal Kinetics of a Single Kinase.

    PubMed

    Mao, Yu-Ting; Zhu, Julia X; Hanamura, Kenji; Iurilli, Giuliano; Datta, Sandeep Robert; Dalva, Matthew B

    2018-05-16

    Dendritic filopodia select synaptic partner axons by interviewing the cell surface of potential targets, but how filopodia decipher the complex pattern of adhesive and repulsive molecular cues to find appropriate contacts is unknown. Here, we demonstrate in cortical neurons that a single cue is sufficient for dendritic filopodia to reject or select specific axonal contacts for elaboration as synaptic sites. Super-resolution and live-cell imaging reveals that EphB2 is located in the tips of filopodia and at nascent synaptic sites. Surprisingly, a genetically encoded indicator of EphB kinase activity, unbiased classification, and a photoactivatable EphB2 reveal that simple differences in the kinetics of EphB kinase signaling at the tips of filopodia mediate the choice between retraction and synaptogenesis. This may enable individual filopodia to choose targets based on differences in the activation rate of a single tyrosine kinase, greatly simplifying the process of partner selection and suggesting a general principle. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. A method for improving the light intensity distribution in dental light-curing units.

    PubMed

    Arikawa, Hiroyuki; Takahashi, Hideo; Minesaki, Yoshito; Muraguchi, Kouichi; Matsuyama, Takashi; Kanie, Takahito; Ban, Seiji

    2011-01-01

    A method for improving the uniformity of the radiation light from dental light-curing units (LCUs), and the effect on the polymerization of light-activated composite resin are investigated. Quartz-tungsten halogen, plasma-arc, and light-emitting diode LCUs were used, and additional optical elements such as a mixing tube and diffusing screen were employed to reduce the inhomogeneity of the radiation light. The distribution of the light intensity from the light guide tip was measured across the guide tip, as well as the distribution of the surface hardness of the light-activated resin emitted with the LCUs. Although the additional optical elements caused 13.2-25.9% attenuation of the light intensity, the uniformity of the light intensity of the LCUs was significantly improved in the modified LCUs, and the uniformity of the surface hardness of the resin was also improved. Our results indicate that the addition of optical elements to the LCU may be a simple and effective method for reducing inhomogeneity in radiation light from the LCUs.

  12. A novel fiber optic Fabry-Perot structure with a micrometric diameter tip

    NASA Astrophysics Data System (ADS)

    Wang, Xingwei; Xu, Juncheng; Wang, Zhuang; Cooper, Kristie L.; Wang, Anbo

    2006-08-01

    This paper presents a novel fiber optic Fabry-Perot (FP) structure with a micrometric diameter tip. The fabrication of micro scale probes has become essential in intracellular surgery, in cell sensing, manipulation, and injection. It is of great importance in many fields, such as genetics, pathology, criminology, pharmacogenetics, and food safety. With such a tiny protrusion, the sensor can be inserted into micron size cells, say, for DNA analysis. With the FP cavity inside the fiber, the change of optical path difference (OPD) caused by the environment can be demodulated. In addition, the structure is intrinsically capable of temperature compensation. What's more, it is simple, cost-efficient, and compact. Last but not the least, the structure shows promise for nanometric protrusion. Once this goal is achieved, the sensor can be inserted into most cells. The sensor could pave the way for faster, more accurate medical diagnostic tests for countless conditions and may ultimately save lives by allowing earlier disease detection and intervention.

  13. Visualizing the Role of Molecular Orbitals in Charge Transport through Individual Diarylethene Isomers

    PubMed Central

    2016-01-01

    Diarylethene molecules are prototype molecular switches with their two isomeric forms exhibiting strikingly different conductance, while maintaining similar length. We employed low-temperature scanning tunneling microscopy (STM) to resolve the energy and the spatial extend of the molecular orbitals of the open and closed isomers when lying on a Au(111) surface. We find an intriguing difference in the extension of the respective HOMOs and a peculiar energy splitting of the formerly degenerate LUMO of the open isomer. We then lift the two isomers with the tip of the STM and measure the current through the individual molecules. By a simple analytical model of the transport, we show that the previously determined orbital characteristics are essential ingredients for the complete understanding of the transport properties. We also succeeded in switching the suspended molecules by the current, while switching the ones which are in direct contact to the surface occurs nonlocally with the help of the electric field of the tip. PMID:27775886

  14. Electromagnetic articulography treatment for an adult with Broca's aphasia and apraxia of speech.

    PubMed

    Katz, W F; Bharadwaj, S V; Carstens, B

    1999-12-01

    Electromagnetic articulography (EMA) was explored as a means of remediating [s]/[symbol in text] articulation deficits in the speech of an adult with Broca's aphasia and apraxia of speech. Over a 1-month period, the subject was provided with 2 different treatments in a counterbalanced procedure: (1) visually guided biofeedback concerning tongue-tip position and (2) a foil treatment in which a computer program delivered voicing-contrast stimuli for simple repetition. Kinematic and perceptual data suggest improvement resulting from visually guided biofeedback, both for nonspeech oral and, to a lesser extent, speech motor tasks. In contrast, the phonetic contrast treated in the foil condition showed only marginal improvement during the therapy session, with performance dropping back to baseline 10 weeks post-treatment. Although preliminary, the findings suggest that visual biofeedback concerning tongue-tip position can be used to treat nonspeech oral and (to a lesser extent) speech motor behavior in adults with Broca's aphasia and apraxia of speech.

  15. Boeing 18-Inch Fan Rig Broadband Noise Test

    NASA Technical Reports Server (NTRS)

    Ganz, Ulrich W.; Joppa, Paul D.; Patten, Timothy J.; Scharpf, Daniel F.

    1998-01-01

    The purposes of the subject test were to identify and quantify the mechanisms by which fan broadband noise is produced, and to assess the validity of such theoretical models of those mechanisms as may be available. The test was conducted with the Boeing 18-inch fan rig in the Boeing Low-Speed Aeroacoustic Facility (LSAF). The rig was designed to be particularly clean and geometrically simple to facilitate theoretical modeling and to minimize sources of interfering noise. The inlet is cylindrical and is equipped with a boundary layer suction system. The fan is typical of modern high-by-pass ratio designs but is capable of operating with or without fan exit guide vanes (stators), and there is only a single flow stream. Fan loading and tip clearance are adjustable. Instrumentation included measurements of fan performance, the unsteady flow field incident on the fan and stators, and far-field and in-duct acoustic fields. The acoustic results were manipulated to estimate the noise generated by different sources. Significant fan broadband noise was found to come from the rotor self-noise as measured with clean inflow and no boundary layer. The rotor tip clearance affected rotor self-noise somewhat. The interaction of the rotor with inlet boundary layer turbulence is also a significant source, and is strongly affected by rotor tip clearance. High level noise can be generated by a high-order nonuniform rotating at a fraction of the fan speed, at least when tip clearance and loading are both large. Stator-generated noise is the loudest of the significant sources, by a small margin, at least on this rig. Stator noise is significantly affected by propagation through the fan.

  16. Off-axis reflective optical apparatus

    NASA Technical Reports Server (NTRS)

    Ames, Lawrence L. (Inventor); Leary, David F. (Inventor); Mammini, Paul V. (Inventor)

    2005-01-01

    Embodiments of the present invention are directed to a simple apparatus and a convenient and accurate method of mounting the components to form an off-axis reflective optical apparatus such as a collimator. In one embodiment, an off-axis reflective optical apparatus comprises a mounting block having a ferrule holder support surface and an off-axis reflector support surface which is generally perpendicular to the ferrule holder support surface. An optical reflector is mounted on the off-axis reflector support surface and has a reflected beam centerline. The optical reflector has a conic reflective surface and a conic center. A ferrule holder is mounted on the ferrule holder support surface. The ferrule holder provides a ferrule for coupling to an optical fiber and orienting a fiber tip of the optical fiber along a fiber axis toward the optical reflector. The fiber axis is nonparallel to the reflected beam centerline. Prior to mounting the optical reflector to the off-axis reflector support surface and prior to mounting the ferrule holder to the ferrule holder support surface, the optical reflector is movable on the off-axis reflector surface and the ferrule holder is movable on the ferrule holder support surface to align the conic center of the optical reflector with respect to the fiber tip of the optical fiber, and the apparatus has at least one of the following features: (1) the optical reflector is movable on the off-axis reflector support surface to adjust a focus of the fiber tip with respect to the optical reflector, and (2) the ferrule holder is movable on the ferrule holder support surface to adjust the focus of the fiber tip with respect to the optical reflector.

  17. Lack of Critical Slowing Down Suggests that Financial Meltdowns Are Not Critical Transitions, yet Rising Variability Could Signal Systemic Risk.

    PubMed

    Guttal, Vishwesha; Raghavendra, Srinivas; Goel, Nikunj; Hoarau, Quentin

    2016-01-01

    Complex systems inspired analysis suggests a hypothesis that financial meltdowns are abrupt critical transitions that occur when the system reaches a tipping point. Theoretical and empirical studies on climatic and ecological dynamical systems have shown that approach to tipping points is preceded by a generic phenomenon called critical slowing down, i.e. an increasingly slow response of the system to perturbations. Therefore, it has been suggested that critical slowing down may be used as an early warning signal of imminent critical transitions. Whether financial markets exhibit critical slowing down prior to meltdowns remains unclear. Here, our analysis reveals that three major US (Dow Jones Index, S&P 500 and NASDAQ) and two European markets (DAX and FTSE) did not exhibit critical slowing down prior to major financial crashes over the last century. However, all markets showed strong trends of rising variability, quantified by time series variance and spectral function at low frequencies, prior to crashes. These results suggest that financial crashes are not critical transitions that occur in the vicinity of a tipping point. Using a simple model, we argue that financial crashes are likely to be stochastic transitions which can occur even when the system is far away from the tipping point. Specifically, we show that a gradually increasing strength of stochastic perturbations may have caused to abrupt transitions in the financial markets. Broadly, our results highlight the importance of stochastically driven abrupt transitions in real world scenarios. Our study offers rising variability as a precursor of financial meltdowns albeit with a limitation that they may signal false alarms.

  18. Fungal Morphogenesis, from the Polarized Growth of Hyphae to Complex Reproduction and Infection Structures.

    PubMed

    Riquelme, Meritxell; Aguirre, Jesús; Bartnicki-García, Salomon; Braus, Gerhard H; Feldbrügge, Michael; Fleig, Ursula; Hansberg, Wilhelm; Herrera-Estrella, Alfredo; Kämper, Jörg; Kück, Ulrich; Mouriño-Pérez, Rosa R; Takeshita, Norio; Fischer, Reinhard

    2018-06-01

    Filamentous fungi constitute a large group of eukaryotic microorganisms that grow by forming simple tube-like hyphae that are capable of differentiating into more-complex morphological structures and distinct cell types. Hyphae form filamentous networks by extending at their tips while branching in subapical regions. Rapid tip elongation requires massive membrane insertion and extension of the rigid chitin-containing cell wall. This process is sustained by a continuous flow of secretory vesicles that depends on the coordinated action of the microtubule and actin cytoskeletons and the corresponding motors and associated proteins. Vesicles transport cell wall-synthesizing enzymes and accumulate in a special structure, the Spitzenkörper, before traveling further and fusing with the tip membrane. The place of vesicle fusion and growth direction are enabled and defined by the position of the Spitzenkörper, the so-called cell end markers, and other proteins involved in the exocytic process. Also important for tip extension is membrane recycling by endocytosis via early endosomes, which function as multipurpose transport vehicles for mRNA, septins, ribosomes, and peroxisomes. Cell integrity, hyphal branching, and morphogenesis are all processes that are largely dependent on vesicle and cytoskeleton dynamics. When hyphae differentiate structures for asexual or sexual reproduction or to mediate interspecies interactions, the hyphal basic cellular machinery may be reprogrammed through the synthesis of new proteins and/or the modification of protein activity. Although some transcriptional networks involved in such reprogramming of hyphae are well studied in several model filamentous fungi, clear connections between these networks and known determinants of hyphal morphogenesis are yet to be established. Copyright © 2018 American Society for Microbiology.

  19. Lack of Critical Slowing Down Suggests that Financial Meltdowns Are Not Critical Transitions, yet Rising Variability Could Signal Systemic Risk

    PubMed Central

    Hoarau, Quentin

    2016-01-01

    Complex systems inspired analysis suggests a hypothesis that financial meltdowns are abrupt critical transitions that occur when the system reaches a tipping point. Theoretical and empirical studies on climatic and ecological dynamical systems have shown that approach to tipping points is preceded by a generic phenomenon called critical slowing down, i.e. an increasingly slow response of the system to perturbations. Therefore, it has been suggested that critical slowing down may be used as an early warning signal of imminent critical transitions. Whether financial markets exhibit critical slowing down prior to meltdowns remains unclear. Here, our analysis reveals that three major US (Dow Jones Index, S&P 500 and NASDAQ) and two European markets (DAX and FTSE) did not exhibit critical slowing down prior to major financial crashes over the last century. However, all markets showed strong trends of rising variability, quantified by time series variance and spectral function at low frequencies, prior to crashes. These results suggest that financial crashes are not critical transitions that occur in the vicinity of a tipping point. Using a simple model, we argue that financial crashes are likely to be stochastic transitions which can occur even when the system is far away from the tipping point. Specifically, we show that a gradually increasing strength of stochastic perturbations may have caused to abrupt transitions in the financial markets. Broadly, our results highlight the importance of stochastically driven abrupt transitions in real world scenarios. Our study offers rising variability as a precursor of financial meltdowns albeit with a limitation that they may signal false alarms. PMID:26761792

  20. Solid Surface Wetting and the Deployment of Drops in Microgravity

    NASA Technical Reports Server (NTRS)

    Trinh, E. H.; Depew, J.

    1994-01-01

    The complete or partial deployment of liquid samples in low gravity is primarily influenced by the interfacial properties of the specific liquid and solid materials used because the overwhelming bias of the Earth gravitational acceleration is removed. This study addresses the engineering aspects of injecting and deploying drops of prescribed volume into an acoustic positioning chamber in microgravity. The specific problems of interest are the design, testing, and implementation of injector tips to be used in a simuttaneously retracting dual-injector system used in the Drop Physics Module microgravity experiment facility. Prior to release, the liquid to be deployed must be retained within a restricted area at the very end of the injectors even under dynamic stimuli due to continuous injection flow as well as to the stepped motion of the injectors, and the final released drop must have a well determined volume as well as negligible residual linear or angular momentum from the deployment process. The outcome of Earthbased short-duration low gravity experiments had been the selection of two types of injector tips which were flown as back-up parts and were successfully utilized during the USML-1 Spacelab mission. The combination of a larger contact surface, liquid pinning with a sharp edge, and selective coating of strategic tip surfaces with a non-wetting compound has allowed a significant increase in the success rate of deployment of simple and compound drops of aqueous solutions of glycerol and silicone oil. The diameter of the samples studied in the Drop Physics Module ranged between 0.3 and 2.7 cm. The tests conducted onsrbit with a manually operated small device have allowed the calibration of the volume deployed for a few drop sizes. The design for improved tips to be used during the next USML flight is based on these results.

  1. Tips for medical practice success in the upcoming accountable care era.

    PubMed

    Bobbitt, Julian D

    2012-01-01

    Due to the unsustainable cost of healthcare, the movement to accountable care will be inevitable. This author predicts that recent Medicare Accountable Care Organization (ACO) regulations will energize ACO development. There are specific practical strategies every medical practice leader should know in order to navigate this new healthcare environment successfully. There is a window of opportunity, which will not stay open long, to control a medical practice's destiny in molding a fair, sustainable, and successful ACO. Not being prepared and defaulting to the status quo through passivity is also a choice that promises more work for less compensation for medical practices. The choice is clear, and the blueprint for success is available.

  2. Pilot Testing Fall TIPS (Tailoring Interventions for Patient Safety): a Patient-Centered Fall Prevention Toolkit.

    PubMed

    Dykes, Patricia C; Duckworth, Megan; Cunningham, Stephanie; Dubois, Sasha; Driscoll, Melissa; Feliciano, Zinnia; Ferrazzi, Michael; Fevrin, Farah E; Lyons, Stephanie; Lindros, Mary Ellen; Monahan, Allison; Paley, Matthew M; Jean-Pierre, Saby; Scanlan, Maureen

    2017-08-01

    Patient falls during an acute hospitalization cause injury, reduced mobility, and increased costs. The laminated paper Fall TIPS Toolkit (Fall TIPS) provides clinical decision support at the bedside by linking each patient's fall risk assessment with evidence-based interventions. Strategies were needed to integrate this evidence into clinical practice. The Institute for Healthcare Improvement's Framework for Spread is the conceptual model for pilot implementation of Fall TIPS at Brigham and Women's Hospital (BWH; Boston) and Montefiore Medical Center (MMC; Bronx, New York). The key to translating the evidence into practice was engaging stakeholders by leveraging existing shared governance structures, identifying unit champions, holding training sessions for all staff, and implementing auditing to assess and provide feedback on protocol adherence and patient outcomes. BWH unit compliance with using Fall TIPS averaged 82%, the mean fall rate decreased from 3.28 to 2.80 falls per 1,000 patient-days from January through June 2015 versus 2016, and the mean fall with injury rate for these periods decreased from 1.00 to 0.54 per 1,000 patient-days. At MMC, compliance averaged 91%, but the mean fall rate increased marginally from 3.04 to 3.10, while the mean fall with injury rate decreased from 0.47 to 0.31 per 1,000 patient-days. Patient knowledge survey results show improvement in knowledge of the risks for falls and the ways to prevent falls. Engaging hospital and clinical leadership is critical in translating evidence-based care into clinical practice. Barriers to adoption of the protocol have been addressed and detailed to provide guidance for spread to other institutions. Copyright © 2017 The Joint Commission. Published by Elsevier Inc. All rights reserved.

  3. Dual Optical Levers for Atomic Force Microscopy

    NASA Astrophysics Data System (ADS)

    Kawakatsu, Hideki; Bleuler, Hannes; Saito, Takashi; Hiroshi, Kougami

    1995-06-01

    Development of micro machined cantilever and optical lever detection system has greatly facilitated the operation of atomic force microscopy. However, since the detection system measures only the deflection of the cantilever at one set point where the laser beam is focused, care must be taken in implementing force control or in interpreting the acquired data. In this paper, a dual optical lever detection system is introduced, which has the potential to resolve the deformation of the cantilever with multidegree of freedom and thus detect the position of the tip end point with resolution in the 10 pm order. The detection system proved to be effective in real-time monitoring of the behavior of the tip end point while scanning, and in explaining the scanning direction dependence of the acquired images.

  4. Blade vortex interaction noise reduction techniques for a rotorcraft

    NASA Technical Reports Server (NTRS)

    Charles, Bruce D. (Inventor); Hassan, Ahmed A. (Inventor); Tadghighi, Hormoz (Inventor); JanakiRam, Ram D. (Inventor); Sankar, Lakshmi N. (Inventor)

    1996-01-01

    An active control device for reducing blade-vortex interactions (BVI) noise generated by a rotorcraft, such as a helicopter, comprises a trailing edge flap located near the tip of each of the rotorcraft's rotor blades. The flap may be actuated in any conventional way, and is scheduled to be actuated to a deflected position during rotation of the rotor blade through predetermined regions of the rotor azimuth, and is further scheduled to be actuated to a retracted position through the remaining regions of the rotor azimuth. Through the careful azimuth-dependent deployment and retraction of the flap over the rotor disk, blade tip vortices which are the primary source for BVI noise are (a) made weaker and (b) pushed farther away from the rotor disk (that is, larger blade-vortex separation distances are achieved).

  5. Blade vortex interaction noise reduction techniques for a rotorcraft

    NASA Technical Reports Server (NTRS)

    Charles, Bruce D. (Inventor); JanakiRam, Ram D. (Inventor); Hassan, Ahmed A. (Inventor); Tadghighi, Hormoz (Inventor); Sankar, Lakshmi N. (Inventor)

    1998-01-01

    An active control device for reducing blade-vortex interactions (BVI) noise generated by a rotorcraft, such as a helicopter, comprises a trailing edge flap located near the tip of each of the rotorcraft's rotor blades. The flap may be actuated in any conventional way, and is scheduled to be actuated to a deflected position during rotation of the rotor blade through predetermined regions of the rotor azimuth, and is further scheduled to be actuated to a retracted position through the remaining regions of the rotor azimuth. Through the careful azimuth-dependent deployment and retraction of the flap over the rotor disk, blade tip vortices which are the primary source for BVI noise are (a) made weaker and (b) pushed farther away from the rotor disk (that is, larger blade-vortex separation distances are achieved).

  6. Algorithms for the assessment and management of insomnia in primary care

    PubMed Central

    Hilty, Donald; Young, Julie S; Bourgeois, James A; Klein, Sally; Hardin, Kimberly A

    2009-01-01

    Insomnia is a leading cause of sleep disturbance in primary care practice affecting >30% of people in the United States and can result in psychological and physiological consequences. We aim for a focused discussion of some of the underpinnings of insomnia and practical tips for management (eg, algorithms). A PubMed search was conducted using English language papers between 1997–2007, with the terms “sleep,” “insomnia”; “primary care” and “clinics”; “comorbid conditions”; “treatment” and “management.” Sleep, psychiatric and medical disorders significantly affect sleep, causing patient suffering, potentially worsening of other disorders and increasing the use of primary care services. We provide an outline for practical assessment and treatment of insomnia in primary care, including the strengths and weaknesses of medications. PMID:19936140

  7. Nanoscale patterning of gold-coated optical fibers for improved plasmonic sensing

    NASA Astrophysics Data System (ADS)

    Antohe, Iulia; Spasic, Dragana; Delport, Filip; Li, Jiaqi; Lammertyn, Jeroen

    2017-05-01

    Merging surface plasmon resonance (SPR) to fiber optic (FO) technology has brought remarkable achievements in the field by offering attractive advantages over the conventional prism-based SPR platforms, such as simplicity, cost-effectiveness and miniaturization. However, the performance of the existing FO-SPR instruments mainly depends on the device surface condition and in particular on the structural aspect of the thin gold (Au) plasmonic film deposited on the FO substrate. In this work, a simple cost-effective colloidal lithography technique (CLT) was adapted and applied for the first time to the micrometer-sized FO substrate, to design end reflection-type FO-SPR sensors with periodic arrays of Au triangularly-shaped nanostructures on the Au mirror FO tip distal end. The nanopatterned FO-SPR sensor tips were afterwards subjected to refractometric measurements in a sucrose dilution series and subsequently compared with their non-patterned counterparts. It was observed that the spectral dips of the nanopatterned FO-SPR sensor tips were shifted towards longer wavelengths after CLT patterning. Moreover, the sensor sensitivity was improved with up to 25% compared to the conventional non-patterned FO-SPR devices. The obtained results represent important steps in the development of a new generation of FO-SPR sensors with improved performance, which can ultimately be used in various applications, ranging from food analysis and environmental monitoring, to health control and medical diagnosis.

  8. Measurement of doubly differential electron bremsstrahlung cross sections at the end point (tip) for C, Al, Te, Ta and Au

    NASA Astrophysics Data System (ADS)

    García-Alvarez, J. A.; Fernández-Varea, J. M.; Vanin, V. R.; Santos, O. C. B.; Barros, S. F.; Malafronte, A. A.; Rodrigues, C. L.; Martins, M. N.; Koskinas, M. F.; Maidana, N. L.

    2017-08-01

    We have used the low-energy beam line of the São Paulo Microtron accelerator to study the maximum energy transfer point (tip) of electron-atom bremsstrahlung spectra for C, Al, Te, Ta and Au. Absolute cross sections differential in energy and angle of the emitted photon were measured for various electron kinetic energies between 20 and 100 keV, and photon emission angles of 35◦, 90◦ and 131◦. The bremsstrahlung spectra were collected with three HPGe detectors and their response functions were evaluated analytically. Rutherford backscattering spectrometry allowed us to obtain the thicknesses of the targets with good accuracy. We propose a simple model for the tip region of the bremsstrahlung spectrum emitted at a given angle, whose adjustable parameters are the mean energy of the incident beam and its spread as well as an amplitude. The model was fitted simultaneously to the pulse-height distributions recorded at the three angles, determining the doubly differential cross sections from the corresponding amplitudes. The measured values have uncertainties between 3% and 13%. The agreement of the experimental results with the theoretical partial-wave calculations of Pratt and co-workers depends on the analyzed element and angle but is generally satisfactory. In the case of Al and Au, the uncertainty attributed to the theory is probably overestimated.

  9. Thermally Dried Ink-Jet Process for 6,13-Bis(triisopropylsilylethynyl)-Pentacene for High Mobility and High Uniformity on a Large Area Substrate

    NASA Astrophysics Data System (ADS)

    Ryu, Gi Seong; Lee, Myung Won; Jeong, Seung Hyeon; Song, Chung Kun

    2012-05-01

    In this study we developed a simple ink-jet process for 6,13-bis(triisopropylsilylethynyl)-pentacene (TIPS-pentacene), which is known as a high-mobility soluble organic semiconductor, to achieve relatively high-mobility and high-uniformity performance for large-area applications. We analyzed the behavior of fluorescent particles in droplets and applied the results to determining a method of controlling the behavior of TIPS-pentacene molecules. The grain morphology of TIPS-pentacene varied depending on the temperature applied to the droplets during drying. We were able to obtain large and uniform grains at 46 °C without any “coffee stain”. The process was applied to a large-size organic thin-film transistor (OTFT) backplane for an electrophoretic display panel containing 192×150 pixels on a 6-in.-sized substrate. The average of mobilities of 36 OTFTs, which were taken from different locations of the backplane, was 0.44±0.08 cm2·V-1·s-1, with a small deviation of 20%, over a 6-in.-size area comprising 28,800 OTFTs. This process providing high mobility and high uniformity can be achieved by simply maintaining the whole area of the substrate at a specific temperature (46 °C in this case) during drying of the droplets.

  10. Controlled growth of hexagonal gold nanostructures during thermally induced self-assembling on Ge(001) surface

    PubMed Central

    Jany, B. R.; Gauquelin, N.; Willhammar, T.; Nikiel, M.; van den Bos, K. H. W.; Janas, A.; Szajna, K.; Verbeeck, J.; Van Aert, S.; Van Tendeloo, G.; Krok, F.

    2017-01-01

    Nano-sized gold has become an important material in various fields of science and technology, where control over the size and crystallography is desired to tailor the functionality. Gold crystallizes in the face-centered cubic (fcc) phase, and its hexagonal closed packed (hcp) structure is a very unusual and rare phase. Stable Au hcp phase has been reported to form in nanoparticles at the tips of some Ge nanowires. It has also recently been synthesized in the form of thin graphene-supported sheets which are unstable under electron beam irradiation. Here, we show that stable hcp Au 3D nanostructures with well-defined crystallographic orientation and size can be systematically created in a process of thermally induced self-assembly of thin Au layer on Ge(001) monocrystal. The Au hcp crystallite is present in each Au nanostructure and has been characterized by different electron microscopy techniques. We report that a careful heat treatment above the eutectic melting temperature and a controlled cooling is required to form the hcp phase of Au on a Ge single crystal. This new method gives scientific prospects to obtain stable Au hcp phase for future applications in a rather simple manner as well as redefine the phase diagram of Gold with Germanium. PMID:28195226

  11. Controlled growth of hexagonal gold nanostructures during thermally induced self-assembling on Ge(001) surface

    NASA Astrophysics Data System (ADS)

    Jany, B. R.; Gauquelin, N.; Willhammar, T.; Nikiel, M.; van den Bos, K. H. W.; Janas, A.; Szajna, K.; Verbeeck, J.; van Aert, S.; van Tendeloo, G.; Krok, F.

    2017-02-01

    Nano-sized gold has become an important material in various fields of science and technology, where control over the size and crystallography is desired to tailor the functionality. Gold crystallizes in the face-centered cubic (fcc) phase, and its hexagonal closed packed (hcp) structure is a very unusual and rare phase. Stable Au hcp phase has been reported to form in nanoparticles at the tips of some Ge nanowires. It has also recently been synthesized in the form of thin graphene-supported sheets which are unstable under electron beam irradiation. Here, we show that stable hcp Au 3D nanostructures with well-defined crystallographic orientation and size can be systematically created in a process of thermally induced self-assembly of thin Au layer on Ge(001) monocrystal. The Au hcp crystallite is present in each Au nanostructure and has been characterized by different electron microscopy techniques. We report that a careful heat treatment above the eutectic melting temperature and a controlled cooling is required to form the hcp phase of Au on a Ge single crystal. This new method gives scientific prospects to obtain stable Au hcp phase for future applications in a rather simple manner as well as redefine the phase diagram of Gold with Germanium.

  12. What do reviewers look for in an original research article?

    PubMed

    Shankar, P R

    2012-01-01

    In this article common errors committed by authors especially those, whose first language is not English, while writing an original research articleis described. Avoiding common errors and improving chances of publication has also been covered. This article may resemble instruction to the author. However, tips from reviewer's eyes has been given. The abstract is the section of the paper most commonly read and care should be taken while writing this section. Keywordsare usedto retrieve articles following searches and use of words from the MeSH database is recommended.The introduction describes work already conducted in the particular area and briefly mentions how the manuscript will add to the existing knowledge.The methods section describes how the study was conducted, is written in the past tense and is often the first part of the paper to be written. The results describe what was found in the study and is usually written after the methods section.The discussion compares the study with the literature and helps to put the study findings in context. The conclusions should be based on the results of the study. The references should be written strictly according to the journal format. Language should be simple, active voice should be used and jargon avoided. Avoid directly quoting from reference articles and paraphrase these in your own words to avoid plagiarism.

  13. Enhancing sensitivity of biconical tapered fiber sensors with multiple passes through the taper

    NASA Astrophysics Data System (ADS)

    Cohoon, Gregory; Boyter, Chris; Errico, Michael; Vandervoort, Kurt; Salik, Ertan

    2010-03-01

    A single biconical fiber taper is a simple and low-cost yet powerful sensor. With a distinct strength in refractive index (RI) sensing, biconical tapered fiber sensors can find their place in handheld sensor platforms, especially as biosensors that are greatly needed in health care, environmental protection, food safety, and biodefense. We report doubling of sensitivity for these sensors with two passes through the tapered region, which becomes possible through the use of sensitive and high-dynamic-range photodetectors. In a proof-of-principle experiment, we measured transmission through the taper when it was immersed in isopropyl alcohol-water mixtures of varying concentrations, in which a thin gold layer at the tip of the fiber acted as a mirror enabling two passes through the tapered region. This improved the sensitivity from 0.43 dB/vol % in the single-pass case to 0.78 dB/vol % with two passes through the taper. The refractive index detection limit was estimated to be ~1.2×10-5 RI units (RIU) and ~0.6×10-5 RIU in the single- and double-pass schemes, respectively. We predict that further enhancement of sensitivity may be achieved with a higher number of passes through the taper.

  14. Separating the Influence of Environment from Stress Relaxation Effects on Dwell Fatigue Crack Growth in a Nickel-Base Disk Alloy

    NASA Technical Reports Server (NTRS)

    Telesman, J.; Gabb, T. P.; Ghosn, L. J.

    2016-01-01

    Both environmental embrittlement and crack tip visco-plastic stress relaxation play a significant role in determining the dwell fatigue crack growth (DFCG) resistance of nickel-based disk superalloys. In the current study performed on the Low Solvus High Refractory (LSHR) disk alloy, the influence of these two mechanisms were separated so that the effects of each could be quantified and modeled. Seven different microstructural variations of LSHR were produced by controlling the cooling rate and the subsequent aging and thermal exposure heat treatments. Through cyclic fatigue crack growth testing performed both in air and vacuum, it was established that four out of the seven LSHR heat treatments evaluated, possessed similar intrinsic environmental resistance to cyclic crack growth. For these four heat treatments, it was further shown that the large differences in dwell crack growth behavior which still persisted, were related to their measured stress relaxation behavior. The apparent differences in their dwell crack growth resistance were attributed to the inability of the standard linear elastic fracture mechanics (LEFM) stress intensity parameter to account for visco-plastic behavior. Crack tip stress relaxation controls the magnitude of the remaining local tensile stresses which are directly related to the measured dwell crack growth rates. It was hypothesized that the environmentally weakened grain boundary crack tip regions fail during the dwells when their strength is exceeded by the remaining local crack tip tensile stresses. It was shown that the classical creep crack growth mechanisms such as grain boundary sliding did not contribute to crack growth, but the local visco-plastic behavior still plays a very significant role by determining the crack tip tensile stress field which controls the dwell crack growth behavior. To account for the influence of the visco-plastic behavior on the crack tip stress field, an empirical modification to the LEFM stress intensity parameter, Kmax, was developed by incorporating into the formulation the remaining stress level concept as measured by simple stress relaxation tests. The newly proposed parameter, Ksrf, did an excellent job in correlating the dwell crack growth rates for the four heat treatments which were shown to have similar intrinsic environmental cyclic fatigue crack growth resistance.

  15. Self-Care for Nurse Leaders in Acute Care Environment Reduces Perceived Stress: A Mixed-Methods Pilot Study Merits Further Investigation.

    PubMed

    Dyess, Susan Mac Leod; Prestia, Angela S; Marquit, Doren-Elyse; Newman, David

    2018-03-01

    Acute care practice settings are stressful. Nurse leaders face stressful demands of numerous competing priorities. Some nurse leaders experience unmanageable stress, but success requires self-care. This article presents a repeated measures intervention design study using mixed methods to investigate a self-care simple meditation practice for nurse leaders. Themes and subthemes emerged in association with the three data collection points: at baseline (pretest), after 6 weeks, and after 12 weeks (posttest) from introduction of the self-care simple meditation practice. An analysis of variance yielded a statistically significant drop in perceived stress at 6 weeks and again at 12 weeks. Conducting future research is merited.

  16. Hood of the truck statistics for food animal practitioners.

    PubMed

    Slenning, Barrett D

    2006-03-01

    This article offers some tips on working with statistics and develops four relatively simple procedures to deal with most kinds of data with which veterinarians work. The criterion for a procedure to be a "Hood of the Truck Statistics" (HOT Stats) technique is that it must be simple enough to be done with pencil, paper, and a calculator. The goal of HOT Stats is to have the tools available to run quick analyses in only a few minutes so that decisions can be made in a timely fashion. The discipline allows us to move away from the all-too-common guess work about effects and differences we perceive following a change in treatment or management. The techniques allow us to move toward making more defensible, credible, and more quantifiably "risk-aware" real-time recommendations to our clients.

  17. A miniature extrinsic fiber Fabry-Perot pressure sensor based on fiber etching

    NASA Astrophysics Data System (ADS)

    Ge, Yixian; Wang, Ming; Yang, Chundi

    2009-10-01

    This paper presents a miniature fiber optic pressure sensor based on Fabry-Perot interference fabricated on the tip of a single mode (SM) fiber. The sensor measures only 125μm in diameter. A Fabry-Perot cavity and a thin silica diaphragm are fabricated by simple techniques involving only fusion splicing, cleaving, and wet chemical etching. Interference pattern of the sensor is analyzed and issues in sensor design are discussed. The overall chemical reaction of the fiber wet etching is specifically represented. Pressure testing system is carried out. By tracing a peak point in the interference spectrum, the gap length of the sensor can be demodulated. The sensor is made entirely of fused silica, whose structure has good stability, cabinet, simple for fabrication and low cost. It may also find uses in medical applications.

  18. A miniature extrinsic fiber Fabry-Perot pressure sensor based on fiber etching

    NASA Astrophysics Data System (ADS)

    Ge, Yixian; Zhou, Junping; Wang, Tingting

    2011-11-01

    A miniature fiber optic pressure sensor based on Fabry-Perot interference fabricated on the tip of a single mode (SM) fiber is presented. The sensor measures only 125μm in diameter. A Fabry-Perot cavity and a thin silica diaphragm are fabricated by simple techniques involving only cleaving, wet chemical etching and fusion splicing. Interference pattern of the sensor is analyzed and issues in sensor design are discussed. The overall chemical reaction of the fiber wet etching is specifically represented. Pressure testing system is carried out. By tracing a peak point in the interference spectrum, the gap length of the sensor can be demodulated. Experimental results show the sensor has a good linearity. The sensor is made entirely of fused silica, whose structure has good stability, cabinet, simple for fabrication and low cost.

  19. The Kinematics of Plant Nutation Reveals a Simple Relation between Curvature and the Orientation of Differential Growth.

    PubMed

    Bastien, Renaud; Meroz, Yasmine

    2016-12-01

    Nutation is an oscillatory movement that plants display during their development. Despite its ubiquity among plants movements, the relation between the observed movement and the underlying biological mechanisms remains unclear. Here we show that the kinematics of the full organ in 3D give a simple picture of plant nutation, where the orientation of the curvature along the main axis of the organ aligns with the direction of maximal differential growth. Within this framework we reexamine the validity of widely used experimental measurements of the apical tip as markers of growth dynamics. We show that though this relation is correct under certain conditions, it does not generally hold, and is not sufficient to uncover the specific role of each mechanism. As an example we re-interpret previously measured experimental observations using our model.

  20. Out of pocket expenditure to deliver at public health facilities in India: a cross sectional analysis.

    PubMed

    Issac, Anns; Chatterjee, Susmita; Srivastava, Aradhana; Bhattacharyya, Sanghita

    2016-08-24

    To expand access to safe deliveries, some developing countries have initiated demand-side financing schemes promoting institutional delivery. In the context of conditional cash incentive scheme and free maternity care in public health facilities in India, studies have highlighted high out of pocket expenditure (OOPE) of Indian families for delivery and maternity care. In this context the study assesses the components of OOPE that women incurred while accessing maternity care in public health facilities in Uttar Pradesh, India. It also assesses the determinants of OOPE and the level of maternal satisfaction while accessing care from these facilities. It is a cross-sectional analysis of 558 recently delivered women who have delivered at four public health facilities in Uttar Pradesh, India. All OOPE related information was collected through interviews using structured pre-tested questionnaires. Frequencies, Mann-Whitney test and categorical regression were used for data reduction. The analysis showed that the median OOPE was INR 700 (US$ 11.48) which varied between INR 680 (US$ 11.15) for normal delivery and INR 970 (US$ 15.9) for complicated cases. Tips for getting services (consisting of gifts and tips for services) with a median value of INR 320 (US$ 5.25) contributed to the major share in OOPE. Women from households with income more than INR 4000 (US$ 65.57) per month, general castes, primi-gravida, complicated delivery and those not accompanied by community health workers incurred higher OOPE. The significant predictors for high OOPE were caste (General Vs. OBC, SC/ST), type of delivery (Complicated Vs. Normal), and presence of ASHA (No Vs. Yes). OOPE while accessing care for delivery was one among the least satisfactory items and 76 % women expressed their dissatisfaction. Even though services at the public health facilities in India are supposed to be provided free of cost, it is actually not free, and the women in this study paid almost half of their mandated cash incentives to obtain delivery care.

  1. Trauma-Informed Care for Children Exposed to Violence: "Tips for Teachers"

    ERIC Educational Resources Information Center

    Office of Juvenile Justice and Delinquency Prevention, 2011

    2011-01-01

    Children are very resilient--but they are not unbreakable. No matter what their age, children are deeply hurt when they are physically, sexually, or emotionally abused or when they see or hear violence in their homes and communities. When children see and hear too much that is frightening, their world feels unsafe and insecure. This brief report…

  2. Contraceptive Care of Adolescents: Overview, Tips, Strategies, and Implications for School Nurses

    ERIC Educational Resources Information Center

    Gabzdyl, Elizabeth Mary

    2010-01-01

    The United States has one of the highest unintended pregnancy rates of all industrialized nations in the world, with 13% of those occurring among the adolescent population. In 2005, the adolescent birthrate in the United States was 40.5 per 1,000 women and increased 3% in 2006 (Martin et al., 2009). Unintended pregnancy and motherhood can have a…

  3. Teachers Helping Parents To Raise the Level of Curiosity in Young Children.

    ERIC Educational Resources Information Center

    Green, Methlyn

    This paper presents methods by which teachers can show parents how to use opportunities they have in everyday life to peak the interest and curiosity of their children. It establishes steps to build a workshop for teachers and day care providers, sharing tips and advice and displaying books and materials which parents can use in their homes. After…

  4. Lesson Closure: An Important Piece of the Student Learning Puzzle

    ERIC Educational Resources Information Center

    Ganske, Kathy

    2017-01-01

    As we seek ways to improve literacy teaching and learning, we need to be careful not to overlook lesson closure as an opportunity to solidify student learning. This Teaching Tip describes the importance of taking time at the ends of lessons, days, and weeks to revisit what students have learned as a means for helping them synthesize and assimilate…

  5. Living in France. A Brief Introduction or Review of the Culture and Language of France for Visitors, Students and Business Travelers. Third revised Edition.

    ERIC Educational Resources Information Center

    Hawkinson, Anni; Moran, Patrick R.

    The guide offers practical information on various aspects of daily living in France, including: money; food; restaurants; hotels; postal and telecommunications services; transportation; shopping; health and medical care; safety and security; tipping; electricity; measurement and clothing size conversions; greetings and leave-takings; names,…

  6. Born To Read: How To Nurture a Baby's Love of Learning. [Videotape and Planner's Manual].

    ERIC Educational Resources Information Center

    Association for Library Service to Children, Chicago, IL.

    The "Born To Read" project helps parents raise children with healthy bodies and minds. Public librarians and health care professionals form partnerships and reach out to at-risk expectant and new parents. The video provides techniques and tips to plan successful programs for babies, including a segment for libraries to use with the…

  7. Clinical guidelines on central venous catheterisation. Swedish Society of Anaesthesiology and Intensive Care Medicine.

    PubMed

    Frykholm, P; Pikwer, A; Hammarskjöld, F; Larsson, A T; Lindgren, S; Lindwall, R; Taxbro, K; Oberg, F; Acosta, S; Akeson, J

    2014-05-01

    Safe and reliable venous access is mandatory in modern health care, but central venous catheters (CVCs) are associated with significant morbidity and mortality, This paper describes current Swedish guidelines for clinical management of CVCs The guidelines supply updated recommendations that may be useful in other countries as well. Literature retrieval in the Cochrane and Pubmed databases, of papers written in English or Swedish and pertaining to CVC management, was done by members of a task force of the Swedish Society of Anaesthesiology and Intensive Care Medicine. Consensus meetings were held throughout the review process to allow all parts of the guidelines to be embraced by all contributors. All of the content was carefully scored according to criteria by the Oxford Centre for Evidence-Based Medicine. We aimed at producing useful and reliable guidelines on bleeding diathesis, vascular approach, ultrasonic guidance, catheter tip positioning, prevention and management of associated trauma and infection, and specific training and follow-up. A structured patient history focused on bleeding should be taken prior to insertion of a CVCs. The right internal jugular vein should primarily be chosen for insertion of a wide-bore CVC. Catheter tip positioning in the right atrium or lower third of the superior caval vein should be verified for long-term use. Ultrasonic guidance should be used for catheterisation by the internal jugular or femoral veins and may also be used for insertion via the subclavian veins or the veins of the upper limb. The operator inserting a CVC should wear cap, mask, and sterile gown and gloves. For long-term intravenous access, tunnelled CVC or subcutaneous venous ports are preferred. Intravenous position of the catheter tip should be verified by clinical or radiological methods after insertion and before each use. Simulator-assisted training of CVC insertion should precede bedside training in patients. Units inserting and managing CVC should have quality assertion programmes for implementation and follow-up of routines, teaching, training and clinical outcome. Clinical guidelines on a wide range of relevant topics have been introduced, based on extensive literature retrieval, to facilitate effective and safe management of CVCs. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  8. Keep It Simple: A Lesson in Linking Teens to Health Care

    ERIC Educational Resources Information Center

    Eisler, Alexandra; Avellino, Lia; Chilcoat, Deborah; Schlanger, Karen

    2016-01-01

    The "Keep It Simple" package, which includes a short animated film (available online for streaming or download), a lesson plan, and supporting materials, was designed to be used with adolescents ages 15-19 to empower them to seek sexual and reproductive health care, and emphasize the availability of long-acting reversible contraception…

  9. Effects of underwater turbulence on laser beam propagation and coupling into single-mode optical fiber.

    PubMed

    Hanson, Frank; Lasher, Mark

    2010-06-01

    We characterize and compare the effects of turbulence on underwater laser propagation with theory. Measurements of the coupling efficiency of the focused beam into a single-mode fiber are reported. A simple tip-tilt control system, based on the position of the image centroid in the focal plane, was shown to maintain good coupling efficiency for a beam radius equal to the transverse coherence length, r(0). These results are relevant to high bandwidth communication technology that requires good spatial mode quality.

  10. Herediatary anhidrotic ectodermal dysplasia. Studies in a Nigerian famil.

    PubMed Central

    Familusi, J B; Jaiyesimi, F; Ojo, C O; Attah, E B

    1975-01-01

    Studies in a Nigerian family with hereditary anhidrous ectodermal dysplasia are reported. Microscopical examinations of finger tips for sweat pores were diagnostic in phenotypes, and it is suggested that this simple nonsurgical procedure is a preferred alternative to skin biopsies in the diagnosis of the syndrome. The clinical implications of a tropical environment for the syndrome, as well as the factors that may favour maintenance of the gene in such an environment are discussed. Images FIG. 1 FIG. 2 FIG. 4 FIG. 5 FIG. 6 PMID:1200681

  11. Superlubrication by phonon confinement

    NASA Astrophysics Data System (ADS)

    Wada, Noriyuki; Ishikawa, Makoto; Shiga, Takuma; Shiomi, Junichiro; Suzuki, Masaru; Miura, Kouji

    2018-04-01

    The superlubrication described here, involving confined phonons, is easily achievable and very simple because it uses only submicron islands, smaller than the mean free path of the phonons, to confine phonons. We can achieve superlubrication with a friction force of piconewton order at the submicron island. We can call this phononic lubrication or self-lubrication because phonons induced by tip shearing are confined within the submicron islands and decrease the friction during the subsequent sliding. Phonon confinement should make it possible to directly develop applications for lubricants and ultimately to open a novel avenue of tribology.

  12. Lattice constants of pure methane and carbon dioxide hydrates at low temperatures. Implementing quantum corrections to classical molecular dynamics studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Costandy, Joseph; Michalis, Vasileios K.; Economou, Ioannis G., E-mail: i.tsimpanogiannis@qatar.tamu.edu, E-mail: ioannis.economou@qatar.tamu.edu

    2016-03-28

    We introduce a simple correction to the calculation of the lattice constants of fully occupied structure sI methane or carbon dioxide pure hydrates that are obtained from classical molecular dynamics simulations using the TIP4PQ/2005 water force field. The obtained corrected lattice constants are subsequently used in order to obtain isobaric thermal expansion coefficients of the pure gas hydrates that exhibit a trend that is significantly closer to the experimental behavior than previously reported classical molecular dynamics studies.

  13. Totally implantable venous access devices: evaluation of complications and a prospective comparative study of two different port systems.

    PubMed

    Hartkamp, A; van Boxtel, A J; Zonnenberg, B A; Witteveen, P O

    2000-12-01

    Totally implantable venous access devices (TIVADs) are valuable instruments in case prolonged intravenous therapy is required, but implantation and use of these devices are associated with complications. The purpose of this study was to evaluate perioperative and long-term complications associated with TIVADs. In addition, we compared two different types of TIVADs with respect to implantation, care protocol and patients' comfort. In a retrospective study perioperative and long-term complications in a general oncology population were analysed. In a prospective randomized study comparison of two types of TIVADs was carried out. Perioperative complications occurred in 27 (21.4%) of 126 implanted TIVADs: catheter malposition (16.7%) in 21 patients, pneumothorax (0.8%) in one and haemorrhage (4.0%) in five. Long-term complications appeared in 31 (25.2%) out of 123 TIVADs: thrombosis in 9 (7.3%), especially associated with malposition of the tip of the catheter; infection in 10 (8.1%); extravasation in 2 (1.6%); migration of the catheter tip in 6 (4.8%); pain at reservoir in 3 (2.4%) and inaccessibility of the port in 1 (0.8%). No significant differences were found with respect to implantation, care accessibility and patients' comfort between the two TIVADs. The use of TIVADs is associated with some risk of serious perioperative and long-term complications. In case of thrombotic complications these systems can be saved with appropriate treatment. Correct positioning of the catheter tip is essential to prevent thrombotic complications. In case of TIVAD-related infectious complications, the possibility of saving the TIVAD depends on the causative microorganism and type of infection. Furthermore, to increase patients' satisfaction with TIVADs they should be well informed about the surgical procedure and possible disadvantages of these devices.

  14. Front teeth-to-carina distance in children undergoing cardiac catheterization.

    PubMed

    Hunyady, Agnes I; Pieters, Benjamin; Johnston, Troy A; Jonmarker, Christer

    2008-06-01

    Knowledge of normal front teeth-to-carina distance (FT-C) might prevent accidental bronchial intubation. The aim of the current study was to measure FT-C and to examine whether the Morgan formula for oral intubation depth, i.e., endotracheal tube (ETT) position at front teeth (cm) = 0.10 x height (cm) + 5, gives appropriate guidance when intubating children of different ages. FT-C was measured in 170 infants and children, aged 1 day to 19 yr, undergoing cardiac catheterization. FT-C was obtained as the sum of the ETT length at the upper front teeth/dental ridge and the distance from the ETT tip to the carina. The latter measure was taken from an anterior-posterior chest x-ray. There was close linear correlation between FT-C and height: FT-C (cm) = 0.12 x height (cm) + 5.2, R = 0.98. The linear correlation coefficients (R) for FT-C versus weight and age were 0.78 and 0.91, respectively. If the Morgan formula had been used for intubation, the ETT tip would have been at 90 +/- 4% of FT-C. No patient would have been bronchially intubated, but the ETT tip would have been less than 0.5 cm from the carina in 13 infants. FT-C can be well predicted from the height/length of the child. The Morgan formula provides good guidance for intubation in children but can result in a distal ETT tip position in small infants. Careful auscultation is necessary to ensure correct tube position.

  15. A molecular dynamics investigation into the mechanisms of subsurface damage and material removal of monocrystalline copper subjected to nanoscale high speed grinding

    NASA Astrophysics Data System (ADS)

    Li, Jia; Fang, Qihong; Liu, Youwen; Zhang, Liangchi

    2014-06-01

    This paper investigates the mechanisms of subsurface damage and material removal of monocrystalline copper when it is under a nanoscale high speed grinding of a diamond tip. The analysis was carried out with the aid of three-dimensional molecular dynamics simulations. The key factors that would influence the deformation of the material were carefully explored by analyzing the chip, dislocation movement, and workpiece deformation, which include grinding speed, depth of cut, grid tip radius, crystal orientation and machining angle of copper. An analytical model was also established to predict the emission of partial dislocations during the nanoscale high speed grinding. The investigation showed that a higher grinding velocity, a larger tip radius or a larger depth of cut would result in a larger chipping volume and a greater temperature rise in the copper workpiece. A lower grinding velocity would produce more intrinsic stacking faults. It was also found that the transition of deformation mechanisms depends on the competition between the dislocations and deformation twinning. There is a critical machining angle, at which a higher velocity, a smaller tip radius, or a smaller depth of cut will reduce the subsurface damage and improve the smoothness of a ground surface. The established analytical model showed that the Shockley dislocation emission is most likely to occur with the crystal orientations of (0 0 1)[1 0 0] at 45° angle.

  16. Liquid-phase microextraction for rapid AP-MALDI and quantitation of nortriptyline in biological matrices.

    PubMed

    Wu, Hui-Fen; Ku, Hsin-Yi; Yen, Jyh-Hao

    2008-07-01

    A liquid-phase microextraction (LPME) method using a micropipette with disposable tips was demonstrated for coupling to atmospheric pressure MALDI-MS (AP-MALDI/MS) as a concentrating probe for rapid analysis and quantitative determination of nortriptyline drug from biological matrices including human urine and human plasma. This technique was named as micropipette extraction (MPE). The best optimized parameters of MPE coupled to AP-MALDI/MS experiments were extraction solvent, toluene; extraction time, 5 min; sample agitation rate, 480 rpm; sample pH, 7; salt concentration, 30%; hole size of micropipette tips, 0.61 mm (id); and matrix concentration, 1000 ppm using alpha-cyano-4-hydroxycinnamic acid (CHCA) as a matrix. Three detection modes of AP-MALDI/MS analysis including full scan, selective ion monitor (SIM), and selective reaction monitor (SRM) of MS/MS were also compared for the MPE performance. The results clearly demonstrated that the MS/MS method provides a wider linear range and lower LODs but poor RSDs than the full scan and SIM methods. The LOD values for the MPE under SIM and MS/MS modes in water, urine, and plasma were 6.26, 47.5, and 94.9 nM, respectively. The enrichment factors (EFs) of this current approach were 36.5-43.0 fold in water. In addition, compared to single drop microextraction (SDME) and LPME using a dual gauge microsyringe with a hollow fiber (LPME-HF) technique, the LODs acquired by the MPE method under MS/MS modes were comparable to those of LPME-HF and SDME but it is more convenient than both methods. The advantages of this novel method are simple, easy to use, low cost, and no contamination between experiments since disposable tips were used for the micropipettes. The MPE has the potential to be widely used in the future because it only requires a simple micropipette to perform all extraction processes. We believe that this technique can be a powerful tool for MALDI/MS analysis of biological samples and clinical applications.

  17. Iterative user centered design for development of a patient-centered fall prevention toolkit.

    PubMed

    Katsulis, Zachary; Ergai, Awatef; Leung, Wai Yin; Schenkel, Laura; Rai, Amisha; Adelman, Jason; Benneyan, James; Bates, David W; Dykes, Patricia C

    2016-09-01

    Due to the large number of falls that occur in hospital settings, inpatient fall prevention is a topic of great interest to patients and health care providers. The use of electronic decision support that tailors fall prevention strategy to patient-specific risk factors, known as Fall T.I.P.S (Tailoring Interventions for Patient Safety), has proven to be an effective approach for decreasing hospital falls. A paper version of the Fall T.I.P.S toolkit was developed primarily for hospitals that do not have the resources to implement the electronic solution; however, more work is needed to optimize the effectiveness of the paper version of this tool. We examined the use of human factors techniques in the redesign of the existing paper fall prevention tool with the goal of increasing ease of use and decreasing inpatient falls. The inclusion of patients and clinical staff in the redesign of the existing tool was done to increase adoption of the tool and fall prevention best practices. The redesigned paper Fall T.I.P.S toolkit showcased a built in clinical decision support system and increased ease of use over the existing version. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Novel nano-OLED based probes for very high resolution optical microscopy

    NASA Astrophysics Data System (ADS)

    Zhao, Yiying

    Near-field scanning optical microscopy (NSOM) has been applied in the study of nanomaterials, microelectronics, photonics, plasmonics, cells, and molecules. However, conventional NSOM relies on optically pumped probes, suffering low optical transmission, heating of the tip, and poor reproducibility of probe fabrication, increasing the cost, impeding usability, reducing practical imaging resolution, and limiting NSOM's utility. In this thesis, I demonstrate a novel probe based on a nanoscale, electrically pumped organic light-emitting device (OLED) formed on the tip of a low-cost, commercially available atomic force microscopy (AFM) probe. I describe the structure, fabrication, and principles of this novel probe's operation, and discuss its potential to overcome the limitations of conventional NSOM probes. The broader significance of this work in the field of organic optoelectronics is also discussed. Briefly, OLEDs consist of organic thin films sandwiched between two electrodes. Under bias, electrons and holes are injected into the organic layers, leading to radiative recombination. Depositing a small molecular OLED in vacuum onto a pyramid-tipped AFM probe results in a laminar structure that is highly curved at the tip. Simple electrical modeling predicts concentration of electric field and localized electron injection into the organic layers at the tip, improving the local charge balance in an otherwise electron-starved OLED. Utilizing an "inverted" OLED structure (i.e. cathode on the "bottom"), light emission is localized to sub-200 nm sized, green light emitting regions on probe vertices; light output power in the range of 0.1-0.5 nanowatts was observed, comparable to that of typical fiber based NSOM probes but with greater power efficiency. Massive arrays of similar sub-micron OLEDs were also fabricated by depositing onto textured silicon substrates, demonstrating the superior scalability of the probe fabrication process (e.g. relative to pulled glass fibers). The investigation of the effect of non-planar substrate geometry on charge injection, transport and recombination provides broader insights into OLEDs made on rough substrates, general understanding of OLED operation (e.g. filamentary charge conduction) and degradation, and potentially helps to improve technologically important "inverted" OLED structures.

  19. After the Visit: An Overview of Government and Community Programs Supporting Children with Medical Complexity.

    PubMed

    Olson, Kaitlyn B

    2017-05-04

    The optimal care of children with medical complexity (CMC) requires involvement from a network of professionals that includes physicians, nurses, ancillary service providers, and educators. Pediatric health care providers typically have early and frequent contact with the families of CMC. Therefore, they are in a unique position to connect families to developmental, educational, and psychosocial supports. This article reviews important government and community programs that support CMC living in the United States. It outlines the educational rights of children with disabilities and offers practical tips for collaborating with Early Intervention and the public school system. The article also provides an overview of financial assistance programs, respite care services, and support groups that are beneficial to CMC and their families.

  20. Neurovascular risks of sacral screws with bicortical purchase: an anatomical study.

    PubMed

    Ergur, Ipek; Akcali, Omer; Kiray, Amac; Kosay, Can; Tayefi, Hamid

    2007-09-01

    The aim of this cadaver study is to define the anatomic structures on anterior sacrum, which are under the risk of injury during bicortical screw application to the S1 and S2 pedicles. Thirty formaldehyde-preserved human male cadavers were studied. Posterior midline incision was performed, and soft tissues and muscles were dissected from the posterior part of the lumbosacral region. A 6 mm pedicle screw was inserted between the superior facet of S1 and the S1 foramen. The entry point of the S2 pedicle screw was located between S1 and S2 foramina. S1 and S2 screws were placed on both right and the left sides of all cadavers. Then, all cadavers were turned into supine position. All abdominal and pelvic organs were moved away and carefully observed for any injury. The tips of the sacral screws were marked and the relations with the anatomic structures were defined. The position of the sacral screws relative to the middle and lateral sacral arteries and veins, and the sacral sympathetic trunk were measured. There was no injury to the visceral organs. In four cases, S1 screw tip was in direct contact with middle sacral artery. In two cases, S1 screw tip was in direct contact with middle sacral vein. It was observed that the S1 screw tips were in close proximity to sacral sympathetic trunk on both right and the left sides. The tip of the S2 screw was in contact with middle sacral artery on the left side only in one case. It is found that the tip of the S2 screw was closely located with the middle sacral vein in two cases. The tip of the S2 pedicle screw was in contact with the sacral sympathetic trunk in eight cases on the right side and seven cases on the left side. Lateral sacral vein was also observed to be disturbed by the S1 and S2 screws. As a conclusion, anterior cortical penetration during sacral screw insertion carries a risk of neurovascular injury. The risk of sacral sympathetic trunk and minor vascular structures together with the major neurovascular structures and viscera should be kept in mind.

  1. Twelve essential tools for living the life of whole person health care.

    PubMed

    Schlitz, Marilyn; Valentina, Elizabeth

    2013-01-01

    The integration of body, mind, and spirit has become a key dimension of health education and disease prevention and treatment; however, our health care system remains primarily disease centered. Finding simple steps to help each of us find our own balance can improve our lives, our work, and our relationships. On the basis of interviews with health care experts at the leading edge of the new model of medicine, this article identifies simple tools to improve the health of patients and caregivers.

  2. Deep Needle Procedures: Improving Safety With Ultrasound Visualization

    PubMed Central

    Peabody, Christopher R.; Mandavia, Diku

    2017-01-01

    Abstract Promoting patient safety and increasing health care quality have dominated the health care landscape during the last 15 years. Health care regulators and payers are now tying patient safety outcomes and best practices to hospital reimbursement. Many health care leaders are searching for new technologies that not only make health care for patients safer but also reduce overall health care costs. New advances in ultrasonography have made this technology available to health care providers at the patient’s bedside. Point-of-care ultrasound assistance now aids providers with real-time diagnosis and with visualization for procedural guidance. This is especially true for common deep needle procedures such as central venous catheter insertion, thoracentesis, and paracentesis. There is now mounting evidence that clinician-performed point-of-care ultrasound improves patient safety, enhances health care quality, and reduces health care cost for deep needle procedures. Furthermore, the miniaturization, ease of use, and the evolving affordability of ultrasound have now made this technology widely available. The adoption of point-of-care ultrasonography has reached a tipping point and should be seriously considered the safety standard for all hospital-based deep needle procedures. PMID:24786918

  3. The issue of being touched.

    PubMed

    Solvoll, Betty-Ann; Lindseth, Anders

    2016-06-01

    The purpose of this empirical paper is to shed light on the phenomenon of being touched in professional care practice. The study has a qualitative design and is a phenomenological hermeneutical exploration based on the story of a care provider. In her story, she describes how her interactions with a substance abuser touched her. The narrative data stems from dialogue with her colleagues and demonstrates a moral appeal and challenge in practical care. Investigations reveal that being touched is about allowing one's self to be awakened by the suffering of others. Being touched by others' suffering thus provides the ability "to see" what is at stake. Identifying with one's suffering and the awareness of what is at risk may be factors that "tip" a person's decision toward acting in the best interest of another person. Being touched may muster an individual's courage to engage in "risk-taking" actions in care. This process paves the way to care and represent essential practical knowledge for health care professionals.

  4. Practice tip. Producing newsletters - criteria for success.

    PubMed

    Eckermann, Sarah Louise; McIntyre, Ellen; Magarey, Anne

    2007-01-01

    Newsletters, while informal when compared to peer reviewed journals and organisational reports, are a popular communication tool used to provide and share information, for and about people with a common interest or need. Newsletters are an effective way to build networks and improve communication. As the editors of several newsletters in primary health care, the authors have developed criteria that aim to increase the success of a newsletter.

  5. Usability testing of a Falls Prevention Tool Kit for an inpatient acute care setting.

    PubMed

    Goldsmith, Denise; Zuyev, Lyubov; Benoit, Angie; Chang, Frank Y; Horsky, Jan; Dykes, Patricia

    2009-01-01

    Efforts to prevent falls in the hospital setting involves identifying patients at risk of falling and implementing fall prevention strategies. This poster describes the method and results of Performance Usability Testing on a web-based Fall Prevention Tool Kit (FPTK) developed as part of a research study, (Falls TIPS-Tailoring Interventions for Patient Safety) funded by The Robert Wood Johnson Foundation.

  6. The legal business of dentistry.

    PubMed

    Barrabee, Steve; Kowalski, Michael

    2009-09-01

    Upon graduation and licensure, most dentists anticipate going into the profession of providing dental heath care to patients in an office or clinic setting. The profession is also the business of dentistry. Failure to appreciate documentation requirements for the business of dentistry can result in legal battles that are time-consuming and emotionally draining. This article provides an introduction, issue spotting, and tips to avoid those legal battles.

  7. Doppler-guided retrograde catheterization system

    NASA Astrophysics Data System (ADS)

    Frazin, Leon J.; Vonesh, Michael J.; Chandran, Krishnan B.; Khasho, Fouad; Lanza, George M.; Talano, James V.; McPherson, David D.

    1991-05-01

    The purpose of this study was to investigate a Doppler guided catheterization system as an adjunctive or alternative methodology to overcome the disadvantages of left heart catheterization and angiography. These disadvantages include the biological effects of radiation and the toxic and volume effects of iodine contrast. Doppler retrograde guidance uses a 20 MHz circular pulsed Doppler crystal incorporated into the tip of a triple lumen multipurpose catheter and is advanced retrogradely using the directional flow information provided by the Doppler waveform. The velocity detection limits are either 1 m/second or 4 m/second depending upon the instrumentation. In a physiologic flow model of the human aortic arch, multiple data points revealed a positive wave form when flow was traveling toward the catheter tip indicating proper alignment for retrograde advancement. There was a negative wave form when flow was traveling away from the catheter tip if the catheter was in a branch or bent upon itself indicating improper catheter tip position for retrograde advancement. In a series of six dogs, the catheter was able to be accurately advanced from the femoral artery to the left ventricular chamber under Doppler signal guidance without the use of x-ray. The potential applications of a Doppler guided retrograde catheterization system include decreasing time requirements and allowing safer catheter guidance in patients with atherosclerotic vascular disease and suspected aortic dissection. The Doppler system may allow left ventricular pressure monitoring in the intensive care unit without the need for x-ray and it may allow left sided contrast echocardiography. With pulse velocity detection limits of 4 m/second, this system may allow catheter direction and passage into the aortic root and left ventricle in patients with aortic stenosis. A modification of the Doppler catheter may include transponder technology which would allow precise catheter tip localization once the catheter tip is placed in the aortic root. Such technology may conceivably assist in allowing selective coronary catheterization. These studies have demonstrated that Doppler guided retrograde catheterization provides an accurate method to catheterization the aortic root and left ventricular chamber without x-ray. In humans, it may prove useful in a variety of settings including the development of invasive ultrasonic diagnostic and therapeutic technology.

  8. Jet Injection of 1% buffered lidocaine versus topical ELA-Max for anesthesia before peripheral intravenous catheterization in children: a randomized controlled trial.

    PubMed

    Spanos, Stephanie; Booth, Rebekah; Koenig, Heidi; Sikes, Kendra; Gracely, Edward; Kim, In K

    2008-08-01

    Peripheral intravenous (PIV) catheter insertion is a frequent, painful procedure that is often performed with little or no anesthesia. Current approaches that minimize pain for PIV catheter insertion have several limitations: significant delay for onset of anesthesia, inadequate anesthesia, infectious disease exposure risk from needlestick injuries, and patients' needle phobia. Comparison of the anesthetic effectiveness of J-Tip needle-free jet injection of 1% buffered lidocaine to the anesthetic effectiveness of topical 4% ELA-Max for PIV catheter insertion. A prospective, block-randomized, controlled trial comparing J-Tip jet injection of 1% buffered lidocaine to a 30-minute application of 4% ELA-Max for topical anesthesia in children 8 to 15 years old presenting to a tertiary care pediatric emergency department for PIV catheter insertion. All subjects recorded self-reported visual analog scale (VAS) scores for pain at time of enrollment and pain felt following PIV catheter insertion. Jet injection subjects also recorded pain of jet injection. Subjects were videotaped during jet injection and PIV catheter insertion. Videotapes were reviewed by a single blinded reviewer for observer-reported VAS pain scores for jet injection and PIV catheter insertion. Of the 70 children enrolled, 35 were randomized to the J-Tip jet injection group and 35 to the ELA-Max group. Patient-recorded enrollment VAS scores for pain were similar between groups (P = 0.74). Patient-recorded VAS scores were significantly different between groups immediately after PIV catheter insertion (17.3 for J-Tip jet injection vs 44.6 for ELA-Max, P < 0.001). Blinded reviewer assessed VAS scores for pain after PIV catheter insertion demonstrated a similar trend, but the comparison was not statistically significant (21.7 for J-Tip jet injection vs 31.9 ELA-Max, P = 0.23). J-Tip jet injection of 1% buffered lidocaine provided greater anesthesia than a 30-minute application of ELA-Max according to patient self-assessment of pain for children aged 8 to 15 years undergoing PIV catheter insertion.

  9. Are abrupt climate changes predictable?

    NASA Astrophysics Data System (ADS)

    Ditlevsen, Peter

    2013-04-01

    It is taken for granted that the limited predictability in the initial value problem, the weather prediction, and the predictability of the statistics are two distinct problems. Lorenz (1975) dubbed this predictability of the first and the second kind respectively. Predictability of the first kind in a chaotic dynamical system is limited due to the well-known critical dependence on initial conditions. Predictability of the second kind is possible in an ergodic system, where either the dynamics is known and the phase space attractor can be characterized by simulation or the system can be observed for such long times that the statistics can be obtained from temporal averaging, assuming that the attractor does not change in time. For the climate system the distinction between predictability of the first and the second kind is fuzzy. This difficulty in distinction between predictability of the first and of the second kind is related to the lack of scale separation between fast and slow components of the climate system. The non-linear nature of the problem furthermore opens the possibility of multiple attractors, or multiple quasi-steady states. As the ice-core records show, the climate has been jumping between different quasi-stationary climates, stadials and interstadials through the Dansgaard-Oechger events. Such a jump happens very fast when a critical tipping point has been reached. The question is: Can such a tipping point be predicted? This is a new kind of predictability: the third kind. If the tipping point is reached through a bifurcation, where the stability of the system is governed by some control parameter, changing in a predictable way to a critical value, the tipping is predictable. If the sudden jump occurs because internal chaotic fluctuations, noise, push the system across a barrier, the tipping is as unpredictable as the triggering noise. In order to hint at an answer to this question, a careful analysis of the high temporal resolution NGRIP isotope record is presented. The result of the analysis points to a fundamental limitation in predictability of the third kind. Reference: P. D. Ditlevsen and S. Johnsen, "Tipping points: Early warning and wishful thinking", Geophys. Res. Lett., 37, 2010

  10. Three-dimensional movement analysis of handwriting in subjects with mild hemiparesis.

    PubMed

    Harada, Takako; Okajima, Yasutomo; Takahashi, Hidetoshi

    2010-08-01

    To investigate the effects of hemiparesis on handwriting using a 3-dimensional movement analyzer. Comparative case study. Ambulatory care clinic. Right-handed patients (n=25; mean age +/- SD, 62.3+/-10y) with mild right hemiparesis secondary to subcortical stroke, and age-matched (n=10; 65.6+/-13y) and age-unmatched (n=15; 32.4+/-10y) control subjects. Not applicable. Time required to write a Japanese character of 2 different sizes and average speed of handwriting at the pen tip. Average radii of tracks of the moving pen tip, metacarpal head of the index finger, and distal end of the forearm during writing. Correlation coefficients of the instantaneous speed-time graph of the pen tip with that of the index finger and with that of the distal forearm during writing. Time for writing with the hemiparetic right hand was longer than that with the unaffected left hand (P=.05 approximately .03), while it was shorter in healthy control subjects (P=.07 approximately .05). In contrast with the left-hand writing, the track radius of the pen tip of the right-hand writing in patients with hemiparesis with normal joint position sense was significantly larger than that of the finger or distal forearm (P=.01). The finding was the same as in the young and elderly control subjects. This right-left difference disappeared in the patients with hemiparesis with position sense impairment. The correlation coefficient of speed between the pen tip and the finger was larger in right-hand than left-hand writing in the control and sensory-normative patients with hemiparesis even though the difference was significant only in the healthy elderly subjects (P=.03). Irrespective of the right or left hand use, the correlation coefficient between the pen tip and the finger or distal forearm significantly increased as the character size increased (P=.03 approximately 6 x10(-6)) in all subjects and patients. However, this size-related difference was less significant in the patients with sensory impairment. The characteristics of handwriting movement by the dominant hand were preserved in patients with mild dominant-hand hemiparesis when joint position sense was normative but were lost in those with position sense impairment.

  11. A nontransferring dry adhesive with hierarchical polymer nanohairs.

    PubMed

    Jeong, Hoon Eui; Lee, Jin-Kwan; Kim, Hong Nam; Moon, Sang Heup; Suh, Kahp Y

    2009-04-07

    We present a simple yet robust method for fabricating angled, hierarchically patterned high-aspect-ratio polymer nanohairs to generate directionally sensitive dry adhesives. The slanted polymeric nanostructures were molded from an etched polySi substrate containing slanted nanoholes. An angled etching technique was developed to fabricate slanted nanoholes with flat tips by inserting an etch-stop layer of silicon dioxide. This unique etching method was equipped with a Faraday cage system to control the ion-incident angles in the conventional plasma etching system. The polymeric nanohairs were fabricated with tailored leaning angles, sizes, tip shapes, and hierarchical structures. As a result of controlled leaning angle and bulged flat top of the nanohairs, the replicated, slanted nanohairs showed excellent directional adhesion, exhibiting strong shear attachment (approximately 26 N/cm(2) in maximum) in the angled direction and easy detachment (approximately 2.2 N/cm(2)) in the opposite direction, with a hysteresis value of approximately 10. In addition to single scale nanohairs, monolithic, micro-nanoscale combined hierarchical hairs were also fabricated by using a 2-step UV-assisted molding technique. These hierarchical nanoscale patterns maintained their adhesive force even on a rough surface (roughness <20 microm) because of an increase in the contact area by the enhanced height of hierarchy, whereas simple nanohairs lost their adhesion strength. To demonstrate the potential applications of the adhesive patch, the dry adhesive was used to transport a large-area glass (47.5 x 37.5 cm(2), second-generation TFT-LCD glass), which could replace the current electrostatic transport/holding system with further optimization.

  12. A nontransferring dry adhesive with hierarchical polymer nanohairs

    PubMed Central

    Jeong, Hoon Eui; Lee, Jin-Kwan; Kim, Hong Nam; Moon, Sang Heup; Suh, Kahp Y.

    2009-01-01

    We present a simple yet robust method for fabricating angled, hierarchically patterned high-aspect-ratio polymer nanohairs to generate directionally sensitive dry adhesives. The slanted polymeric nanostructures were molded from an etched polySi substrate containing slanted nanoholes. An angled etching technique was developed to fabricate slanted nanoholes with flat tips by inserting an etch-stop layer of silicon dioxide. This unique etching method was equipped with a Faraday cage system to control the ion-incident angles in the conventional plasma etching system. The polymeric nanohairs were fabricated with tailored leaning angles, sizes, tip shapes, and hierarchical structures. As a result of controlled leaning angle and bulged flat top of the nanohairs, the replicated, slanted nanohairs showed excellent directional adhesion, exhibiting strong shear attachment (≈26 N/cm2 in maximum) in the angled direction and easy detachment (≈2.2 N/cm2) in the opposite direction, with a hysteresis value of ≈10. In addition to single scale nanohairs, monolithic, micro-nanoscale combined hierarchical hairs were also fabricated by using a 2-step UV-assisted molding technique. These hierarchical nanoscale patterns maintained their adhesive force even on a rough surface (roughness <20 μm) because of an increase in the contact area by the enhanced height of hierarchy, whereas simple nanohairs lost their adhesion strength. To demonstrate the potential applications of the adhesive patch, the dry adhesive was used to transport a large-area glass (47.5 × 37.5 cm2, second-generation TFT-LCD glass), which could replace the current electrostatic transport/holding system with further optimization. PMID:19304801

  13. Simple method for RF pulse measurement using gradient reversal.

    PubMed

    Landes, Vanessa L; Nayak, Krishna S

    2018-05-01

    To develop and evaluate a simple method for measuring the envelope of small-tip radiofrequency (RF) excitation waveforms in MRI, without extra hardware or synchronization. Gradient reversal approach to evaluate RF (GRATER) involves RF excitation with a constant gradient and reversal of that gradient during signal reception to acquire the time-reversed version of an RF envelope. An outer-volume suppression prepulse is used optionally to preselect a uniform volume. GRATER was evaluated in phantom and in vivo experiments. It was compared with the programmed waveform and the traditional pick-up coil method. In uniform phantom experiments, pick-up coil, GRATER, and outer-volume suppression + GRATER matched the programmed waveforms to less than 2.1%, less than 6.1%, and less than 2.4% normalized root mean square error, respectively, for real RF pulses with flip angle less than or equal to 30°, time-bandwidth product 2 to 8, and two to five excitation bands. For flip angles greater than 30°, GRATER measurement error increased as predicted by Bloch simulation. Fat-water phantom and in vivo experiments with outer-volume suppression + GRATER demonstrated less than 6.4% normalized root mean square error. The GRATER sequence measures small-tip RF envelopes without extra hardware or synchronization in just over two times the RF duration. The sequence may be useful in prescan calibration and for measurement and precompensation of RF amplifier nonlinearity. Magn Reson Med 79:2642-2651, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  14. Nurse staffing issues are just the tip of the iceberg: a qualitative study about nurses' perceptions of nurse staffing.

    PubMed

    van Oostveen, Catharina J; Mathijssen, Elke; Vermeulen, Hester

    2015-08-01

    To obtain in-depth insight into the perceptions of nurses in the Netherlands regarding current nurse staffing levels and use of nurse-to-patient-ratios (NPR) and patient classification systems (PCS). In response to rising health care demands due to ageing of the patient population and increasing complexity of healthcare, hospital boards have been implementing NPRs and PCSs. However, many nurses at the unit level believe that staffing levels have become critically low, endangering the quality and safety of their patient care. This descriptive phenomenological qualitative study was conducted in a 1000-bed Dutch university hospital among 24 wards of four specialties (surgery, internal medicine, neurology, gynaecology & obstetrics and paediatric care). Data were collected from September until December 2012. To collect data four focus groups (n=44 nurses) were organized. Additionally, a total of 27 interviews (20 head nurses, 4 nurse directors and 3 quality advisors) were conducted using purposive sampling. The focus groups and interviews were audiotaped, transcribed and subjected to thematic analysis. Nurse staffing issues appear to be merely the 'tip of the iceberg'. Below the surface three underlying main themes became clear - nursing behaviour, authority, and autonomy - which are linked by one overall theme: nurses' position. In general, nurses' behaviour, way of thinking, decision-making and communication of thoughts or information differs from other healthcare disciplines, e.g. physicians and quality advisors. This results in a perceived and actual lack of authority and autonomy. This in turn hinders them to plead for adequate nurse staffing in order to achieve the common goal of safe and high-quality patient care. Nurses desired a valid nursing care intensity system as an interdisciplinary and objective communication tool that makes nursing care visible and creates possibilities for better positioning of nurses in hospitals and further professionalization in terms of enhanced authority and autonomy. The perceived subservient position of nurses in the hospital appears to be the root cause of nurse staffing problems. It is yet unknown whether an objective PCS to measure nursing care intensity would help them communicate effectively and credibly, thereby improving their own position. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Design Principles for Rapid Prototyping Forces Sensors using 3D Printing.

    PubMed

    Kesner, Samuel B; Howe, Robert D

    2011-07-21

    Force sensors provide critical information for robot manipulators, manufacturing processes, and haptic interfaces. Commercial force sensors, however, are generally not adapted to specific system requirements, resulting in sensors with excess size, cost, and fragility. To overcome these issues, 3D printers can be used to create components for the quick and inexpensive development of force sensors. Limitations of this rapid prototyping technology, however, require specialized design principles. In this paper, we discuss techniques for rapidly developing simple force sensors, including selecting and attaching metal flexures, using inexpensive and simple displacement transducers, and 3D printing features to aid in assembly. These design methods are illustrated through the design and fabrication of a miniature force sensor for the tip of a robotic catheter system. The resulting force sensor prototype can measure forces with an accuracy of as low as 2% of the 10 N measurement range.

  16. Autonomous surgical robotics using 3-D ultrasound guidance: feasibility study.

    PubMed

    Whitman, John; Fronheiser, Matthew P; Ivancevich, Nikolas M; Smith, Stephen W

    2007-10-01

    The goal of this study was to test the feasibility of using a real-time 3D (RT3D) ultrasound scanner with a transthoracic matrix array transducer probe to guide an autonomous surgical robot. Employing a fiducial alignment mark on the transducer to orient the robot's frame of reference and using simple thresholding algorithms to segment the 3D images, we tested the accuracy of using the scanner to automatically direct a robot arm that touched two needle tips together within a water tank. RMS measurement error was 3.8% or 1.58 mm for an average path length of 41 mm. Using these same techniques, the autonomous robot also performed simulated needle biopsies of a cyst-like lesion in a tissue phantom. This feasibility study shows the potential for 3D ultrasound guidance of an autonomous surgical robot for simple interventional tasks, including lesion biopsy and foreign body removal.

  17. Dielectrophoresis of Cells

    PubMed Central

    Pohl, Herbert A.; Crane, Joe S.

    1971-01-01

    Dielectrophoresis, the motion produced by the action of nonuniform electric field upon a neutral object, is shown to be a simple and useful technique for the study of cellular organisms. In the present study of yeast (Saccharomyces cerevisiae) using a simple pin-pin electrode system of platinum and high-frequency alternating fields, one observes that the collectability of cells at the electrode tip, i.e. at the region of highest field strength, depends upon physical parameters such as field strength, field uniformity, frequency, cell concentration, suspension conductivity, and time of collection. The yield of cells collected is also observed to depend upon biological factors such as colony age, thermal treatment of the cells, and chemical poisons, but not upon irradiation with ultraviolet light. Several interesting side effect phenomena coincident with nonuniform electric field conditions were observed, including stirring (related to “jet” effects at localized electrode sites), discontinuous repulsions, and cellular rotation which was found to be frequency dependent. ImagesFIGURE 2 PMID:5132497

  18. Changing skewness: an early warning signal of regime shifts in ecosystems.

    PubMed

    Guttal, Vishwesha; Jayaprakash, Ciriyam

    2008-05-01

    Empirical evidence for large-scale abrupt changes in ecosystems such as lakes and vegetation of semi-arid regions is growing. Such changes, called regime shifts, can lead to degradation of ecological services. We study simple ecological models that show a catastrophic transition as a control parameter is varied and propose a novel early warning signal that exploits two ubiquitous features of ecological systems: nonlinearity and large external fluctuations. Either reduced resilience or increased external fluctuations can tip ecosystems to an alternative stable state. It is shown that changes in asymmetry in the distribution of time series data, quantified by changing skewness, is a model-independent and reliable early warning signal for both routes to regime shifts. Furthermore, using model simulations that mimic field measurements and a simple analysis of real data from abrupt climate change in the Sahara, we study the feasibility of skewness calculations using data available from routine monitoring.

  19. DESIGN ANALYSIS OF RADIAL INFLOW TURBINES

    NASA Technical Reports Server (NTRS)

    Glassman, A. J.

    1994-01-01

    This program performs a velocity-diagram analysis required for determining geometry and estimating performance for radial-inflow turbines. Input design requirements are power, mass flow rate, inlet temperature and pressure, and rotative rate. The design variables include stator-exit angle, rotor-exit-tip to rotor-inlet radius ratio, rotor-exit-hub to tip radius ratio, and the magnitude and radial distribution of rotor-exit tangential velocity. The program output includes diameters, total and static efficiences, all absolute and relative temperatures, pressures, and velocities, and flow angles at stator inlet, stator exit, rotor inlet, and rotor exit. Losses accounted for in this program by the internal loss model are three-dimensional (profile plus end wall) viscous losses in the stator and the rotor, the disk-friction loss on the back side of the rotor, the loss due to the clearance between the rotor tip and the outer casing, and the exit velocity loss. The flow analysis is one-dimensional at the stator inlet, stator exit, and rotor inlet, each of these calculation stations being at a constant radius. At the rotor exit where there is a variation in flow-field radius, an axisymmetric two-dimensional analysis is made using constant height sectors. Simple radial equilibrium is used to establish the static pressure gradient at the rotor exit. This program is written in FORTRAN V and has been implemented on a UNIVAC 1100 series computer with a memory requirement of approximately 22K of 36 bit words.

  20. High-temperature dynamic behavior in bulk liquid water: A molecular dynamics simulation study using the OPC and TIP4P-Ew potentials

    NASA Astrophysics Data System (ADS)

    Gabrieli, Andrea; Sant, Marco; Izadi, Saeed; Shabane, Parviz Seifpanahi; Onufriev, Alexey V.; Suffritti, Giuseppe B.

    2018-02-01

    Classical molecular dynamics simulations were performed to study the high-temperature (above 300 K) dynamic behavior of bulk water, specifically the behavior of the diffusion coefficient, hydrogen bond, and nearest-neighbor lifetimes. Two water potentials were compared: the recently proposed "globally optimal" point charge (OPC) model and the well-known TIP4P-Ew model. By considering the Arrhenius plots of the computed inverse diffusion coefficient and rotational relaxation constants, a crossover from Vogel-Fulcher-Tammann behavior to a linear trend with increasing temperature was detected at T* ≈ 309 and T* ≈ 285 K for the OPC and TIP4P-Ew models, respectively. Experimentally, the crossover point was previously observed at T* ± 315-5 K. We also verified that for the coefficient of thermal expansion α P ( T, P), the isobaric α P ( T) curves cross at about the same T* as in the experiment. The lifetimes of water hydrogen bonds and of the nearest neighbors were evaluated and were found to cross near T*, where the lifetimes are about 1 ps. For T < T*, hydrogen bonds persist longer than nearest neighbors, suggesting that the hydrogen bonding network dominates the water structure at T < T*, whereas for T > T*, water behaves more like a simple liquid. The fact that T* falls within the biologically relevant temperature range is a strong motivation for further analysis of the phenomenon and its possible consequences for biomolecular systems.

Top