Sample records for case study installation

  1. Byers Auto Group: A Case Study Into The Economics, Zoning, and Overall Process of Installing Small Wind Turbines at Two Automotive Dealerships in Ohio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oteri, F.; Sinclair, K.

    This paper provides the talking points about a case study on the installation of a $600,000 small wind project, the installation process, estimated annual energy production and percentage of energy needs met by the turbines.

  2. Byers Auto Group: A Case Study Into The Economics, Zoning, and Overall Process of Installing Small Wind Turbines at Two Automotive Dealerships in Ohio (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sinclair, K.; Oteri, F.

    This presentation provides the talking points about a case study on the installation of a $600,000 small wind project, the installation process, estimated annual energy production and percentage of energy needs met by the turbines.

  3. Colorado State University: A Midscale Market Solar Customer Case Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holm, Alison; Chernyakhovskiy, Ilya

    Despite substantial increases in solar photovoltaic (PV) deployment between 2005 and 2015, a large untapped market for solar PV deployment still exists in midscale market investments by universities. Recent estimates show that if all universities in the United States installed enough solar PV to meet 25% of their annual electricity consumption, this would cumulatively result in just over 16 gigawatts (GW) of additional installed PV capacity. Within this context, midscale market projects - loosely defined as solar PV installations ranging from 100 kilowatts (kW) to 2 megawatts (MW), but more broadly representing installations not captured in the residential or utility-scalemore » sectors - could be an attractive option for universities. This case study focuses on one university solar customer, Colorado State University (CSU), to provide a detailed example of the challenges, solutions, and opportunities associated with university solar power procurement. Between 2009 and 2015, a combined 6,754 kW of both ground-mounted and rooftop solar PV was installed across multiple CSU campuses in Fort Collins, Colorado. This case study highlights CSU's decision-making process, campus engagement strategies, and relationships with state, local, and utility partners, which have culminated in significant on-campus PV deployment.« less

  4. A statistical evaluation of formation disturbance produced by well- casing installation methods

    USGS Publications Warehouse

    Morin, R.H.; LeBlanc, D.R.; Teasdale, W.E.

    1988-01-01

    Water-resources investigations concerned with contaminant transport through aquifers comprised of very loose, unconsolidated sediments have shown that small-scale variations in aquifer characteristics can significantly affect solute transport and dispersion. Commonly, measurement accuracy and resolution have been limited by a borehole environment consisting of an annulus of disturbed sediments produced by the casing-installation method. In an attempt to quantify this disturbance and recognize its impact on the characterization of unconsolidated deposits, three installation methods were examined and compared in a sand-and-gravel outwash at a test site on Cape Cod, Massachusetts. These installation methods were: 1) casing installed in a mud-rotary hole; 2) casing installed in an augered hole; and 3) flush-joint steel casing hammer-driven from land surface. Fifteen wells were logged with epithermal neutron and natural gamma tools. Concludes that augering is the most disruptive of the three casing-installation methods and that driving casing directly, though typically a more time-consuming operation, transmits the least amount of disturbance into the surrounding formation. -from Authors

  5. Structural considerations for solar installers : an approach for small, simplified solar installations or retrofits.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richards, Elizabeth H.; Schindel, Kay; Bosiljevac, Tom

    2011-12-01

    Structural Considerations for Solar Installers provides a comprehensive outline of structural considerations associated with simplified solar installations and recommends a set of best practices installers can follow when assessing such considerations. Information in the manual comes from engineering and solar experts as well as case studies. The objectives of the manual are to ensure safety and structural durability for rooftop solar installations and to potentially accelerate the permitting process by identifying and remedying structural issues prior to installation. The purpose of this document is to provide tools and guidelines for installers to help ensure that residential photovoltaic (PV) power systemsmore » are properly specified and installed with respect to the continuing structural integrity of the building.« less

  6. Effects of loop detector installation on the Portland cement concrete pavement lifespan : case study on I-5.

    DOT National Transportation Integrated Search

    2010-08-01

    The installation of loop detectors in portland cement concrete pavement (PCCP) may shorten affected panel life, thus prematurely worsening the condition of the overall pavement. This study focuses on the performance of those loop embedded panels (LEP...

  7. Study on installation of the submersible mixer

    NASA Astrophysics Data System (ADS)

    Tian, F.; Shi, W. D.; He, X. H.; Jiang, H.; Xu, Y. H.

    2013-12-01

    Study on installation of the submersible mixer for sewage treatment has been limited. In this article, large-scale computational fluid dynamics software FLUENT6.3 was adopted. ICEM software was used to build an unstructured grid of sewage treatment pool. After that, the sewage treatment pool was numerically simulated by dynamic coordinate system technology and RNG k-ε turbulent model and PIOS algorithm. Agitation pools on four different installation location cases were simulated respectively, and the external characteristic of the submersible mixer and the velocity cloud of the axial section were respectively comparatively analyzed. The best stirring effect can be reached by the installation location of case C, which is near the bottom of the pool 600 mm and blade distance the bottom at least for 200 mm wide and wide edge and narrow edge distance by 4:3. The conclusion can guide the engineering practice.

  8. 76 FR 65419 - Airworthiness Directives; SOCATA Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-21

    ... case of inverted installation of aileron control cables in the wing. The shortest cable was found... states: A TBM 700 operator reported a case of inverted installation of aileron control cables in the wing... inspection to verify the correct installation of the aileron control cables and, in case of discrepancies...

  9. Interactive mechanism of working environments and construction behaviors with cognitive work analysis: an elevator installation case study.

    PubMed

    Wang, Yanqing; Chong, Heap-Yih; Liao, Pin-Chao; Ren, Hantao

    2017-09-25

    Unsafe behavior is a leading factor in accidents, and the working environment significantly affects behaviors. However, few studies have focused on detailed mechanisms for addressing unsafe behaviors resulting from environmental constraints. This study aims to delineate these mechanisms using cognitive work analysis (CWA) for an elevator installation case study. Elevator installation was selected for study because it involves operations at heights: falls from heights remain a major cause of construction worker mortality. This study adopts a mixed research approach based on three research methodology stages. This research deconstructs the details of the working environment, the workers' decision-making processes, the strategies chosen given environmental conditions and the conceptual model for workers' behaviors, which jointly depict environment-behavior mechanisms at length. By applying CWA to the construction industry, environmental constraints can easily be identified, and targeted engineering suggestions can be generated.

  10. New safety rules challenge U. K. operators, regulators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hudson, J.

    1994-08-15

    Offshore safety regulations based on lessons learned from the Piper Alpha blast of 1988 have been in operation in the U.K. for a year. The Offshore Installations (Safety Case) Regulations 1992 make operators of fixed and mobile installations (the duty holders'') responsible for producing a formal safety assessment, or safety case, for each installation. After the end of November 1995 it will be an offense to operate an installation without a safety case which has been approved by the government's Health and Safety Executive (HSE). Producing safety cases for installations is a major task for duty holder, while assessing themmore » is a huge under taking for HSE's Offshore Safety Division (OSD). This paper reviews how HSE has established management arrangements to handle safety cases, considers progress in assessment, highlights some of the important lessons learned, and look to the future.« less

  11. Seismic Stability Evaluation of Ririe Dam and Reservoir Project. Report 1. Construction History and Field and Laboratory Studies. Volume 1. Main Text

    DTIC Science & Technology

    1991-09-01

    truck Service truck Steel casing, 8-foot diameter with 3/4-inch wall thickness, was installed as the shaft was advanced. A shaft cover, constructed of... steel mats. was hoisted over the shaft at night for security. To obtain in-situ density tests at selected intervals in the bottom of the shaft...subcontractor installed the three wells using an air-rotary rig, and driving steel casing as the wells were advanced. He then perforated the casings

  12. Case report: silicatosis in a carpet installer.

    PubMed

    Szeinuk, Jaime; Wilk-Rivard, Elizabeth J

    2007-06-01

    Chronic exposure to talc in the course of carpet installation can result in pneumoconiosis. We present a case of a young carpet installer who was diagnosed with silicatosis of the lung. Review of occupational history revealed that the patient had been working as a carpet installer for approximately 15 years, since he was 15 years of age. The patient was exposed to talc in the course of his work. Exposure to talc in the course of carpet installation has not been reported as a possible cause of pneumoconiosis. In this article we review different causes of silicatosis and discuss chronic exposure in the course of carpet installation and development of pneumoconiosis. In addition, we also review the relevance of mycobacterial infection in cases of silicosis and silicatosis. Exposure to talc in the course of carpet installation should be added to conditions that can cause pneumoconioses, specifically silicatosis of the lung.

  13. Effect of emergency department CT on neuroimaging case volume and positive scan rates.

    PubMed

    Oguz, Kader Karli; Yousem, David M; Deluca, Tom; Herskovits, Edward H; Beauchamp, Norman J

    2002-09-01

    The authors performed this study to determine the effect a computed tomographic (CT) scanner in the emergency department (ED) has on neuroimaging case volume and positive scan rates. The total numbers of ED visits and neuroradiology CT scans requested from the ED were recorded for 1998 and 2000, the years before and after the installation of a CT unit in the ED. For each examination type (brain, face, cervical spine), studies were graded for major findings (those that affected patient care), minor findings, and normal findings. The CT utilization rates and positive study rates were compared for each type of study performed for both years. There was a statistically significant increase in the utilization rate after installation of the CT unit (P < .001). The fractions of studies with major findings, minor findings, and normal findings changed significantly after installation of the CT unit for facial examinations (P = .002) but not for brain (P = .12) or cervical spine (P = .24) examinations. In all types of studies, the percentage of normal examinations increased. In toto, there was a significant decrease in the positive scan rate after installation of the CT scanner (P = .004). After installation of a CT scanner in the ED, there was increased utilization and a decreased rate of positive neuroradiologic examinations, the latter primarily due to lower positive rates for facial CT scans.

  14. [Robot-Assisted Laparoscopic Radical Prostatectomy for Patients with Prostatic Cancer and Factors Promoting Installation of the Robotic Surgical Equipment-Questionnaire Survey].

    PubMed

    Tsukamoto, Taiji; Tanaka, Shigeru

    2015-08-01

    We conducted a questionnaire survey of hospitals with robot-assisted surgical equipment to study changes of the surgical case loads after its installation and the managerial strategies for its purchase. The study included 154 hospitals (as of April 2014) that were queried about their radical prostatectomy case loads from January 2009 to December 2013, strategies for installation of the equipment in their hospitals, and other topics related to the study purpose. The overall response rate of hospitals was 63%, though it marginally varied according to type and area. The annual case load was determined based on the results of the questionnaire and other modalities. It increased from 3,518 in 2009 to 6,425 in 2013. The case load seemed to be concentrated in hospitals with robot equipment since the increase of their number was very minimal over the 5 years. The hospitals with the robot treated a larger number of newly diagnosed patients with the disease than before. Most of the patients were those having localized cancer that was indicated for radical surgery, suggesting again the concentration of the surgical case loads in the hospitals with robots. While most hospitals believed that installation of a robot was necessary as an option for treatment procedures, the future strategy of the hospital, and other reasons, the action of the hospital to gain prestige may be involved in the process of purchasing the equipment. In conclusion, robot-assisted laparoscopic radical prostatectomy has become popular as a surgical procedure for prostate cancer in our society. This may lead to a concentration of the surgical case load in a limited number of hospitals with robots. We also discuss the typical action of an acute-care hospital when it purchases expensive clinical medical equipment.

  15. Building America Case Study: Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test, Minneapolis, Minnesota

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    T. Schirber, B. Schoenbauer

    High-performance water heaters are typically more time consuming and costly to install in retrofit applications, making high-performance water heaters difficult to justify economically. However, recent advancements in high-performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high-efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands.

  16. Thermal and fluid-dynamics behavior of circulating systems in the case of pressure relief

    NASA Astrophysics Data System (ADS)

    Moeller, L.

    Aspects of safety in the case of large-scale installations with operational high-pressure conditions must be an important consideration already during the design of such installations, taking into account all conceivable disturbances. Within an analysis of such disturbances, studies related to pressure relief processes will have to occupy a central position. For such studies, it is convenient to combine experiments involving small-scale models of the actual installation with suitable computational programs. The experiments can be carried out at lower pressures and temperatures if the actual fluid is replaced by another medium, such as, for instance, a refrigerant. This approach has been used in the present investigation. The obtained experimental data are employed as a basis for a verification of the results provided by the computational model 'Frelap-UK' which has been expressly developed for the analysis of system behavior in the case of pressure relief. It is found that the computer fluid-dynamics characteristics agree with the experimental results.

  17. 49 CFR 192.361 - Service lines: Installation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... installed with at least 12 inches (305 millimeters) of cover in private property and at least 18 inches (457 millimeters) of cover in streets and roads. However, where an underground structure prevents installation at... building must: (1) In the case of a metal service line, be protected against corrosion; (2) In the case of...

  18. Chemical plant innovative safety investments decision-support methodology.

    PubMed

    Reniers, G L L; Audenaert, A

    2009-01-01

    This article examines the extent to which investing in safety during the creation of a new chemical installation proves profitable. The authors propose a management supporting cost-benefit model that identifies and evaluates investments in safety within a chemical company. This innovative model differentiates between serious accidents and less serious accidents, thus providing an authentic image of prevention-related costs and benefits. In classic cost-benefit analyses, which do not make such differentiations, only a rudimentary image of potential profitability resulting from investments in safety is obtained. The resulting management conclusions that can be drawn from such classical analyses are of a very limited nature. The proposed model, however, is applied to a real case study and the proposed investments in safety at an appointed chemical installation are weighed against the estimated hypothetical benefits resulting from the preventive measures to be installed at the installation. In the case-study carried out in question, it would appear that the proposed prevention investments are justified. Such an economic exercise may be very important to chemical corporations trying to (further) improve their safety investments.

  19. Pedestrian safety impacts of curb extensions : a case study : final report.

    DOT National Transportation Integrated Search

    2005-07-01

    This report documents a case study evaluating motorist yielding behavior at a crosswalk in Albany, Oregon. In 2003 the City of Albany installed curb extensions, continental markings and advance stop bars at several uncontrolled intersections along th...

  20. Dispersed storage and generation case studies

    NASA Technical Reports Server (NTRS)

    Bahrami, K.; Stallkamp, J. A.; Walton, A.

    1980-01-01

    Three installations utilizing separate dispersed storage and generation (DSG) technologies were investigated. Each of the systems is described in costs and control. Selected institutional and environmental issues are discussed, including life cycle costs. No unresolved technical, environmental, or institutional problems were encountered in the installations. The wind and solar photovoltaic DSG were installed for test purposes, and appear to be presently uneconomical. However, a number of factors are decreasing the cost of DSG relative to conventional alternatives, and an increased DSG penetration level may be expected in the future.

  1. Downhole geophysical observatories: best installation practices and a case history from Turkey

    NASA Astrophysics Data System (ADS)

    Prevedel, Bernhard; Bulut, Fatih; Bohnhoff, Marco; Raub, Christina; Kartal, Recai F.; Alver, Fatih; Malin, Peter E.

    2015-09-01

    Downhole sensors of different types and in various environments provide substantial benefit to signal quality. They also add the depth dimension to measurements performed at the Earths' surface. Sensor types that particularly benefit from downhole installation due to the absence of near-surface noise include piezometers, seismometers, strainmeters, thermometers, and tiltmeters. Likewise, geochemical and environmental measurements in a borehole help eliminate near-surface weathering and cultural effects. Installations from a few hundred meter deep to a few kilometer deep dramatically reduce surface noise levels—the latter noticeably also reduces the hypocentral distance for shallow microearthquakes. The laying out of a borehole network is always a compromise of local boundary conditions and the involved drilling costs. The installation depth and procedure for a long-term downhole observatory can range from time limited installations, with a retrieval option, to permanently cemented sensors. Permanently cemented sensors have proven to be long-term stable with non-deteriorating coupling and borehole integrity. However, each type needs to be carefully selected and planned according to the research aims. A convenient case study is provided by a new installation of downhole seismometers along the shoreline of the eastern Marmara Sea in Turkey. These stations are being integrated into the regional net for monitoring the North Anatolian Fault Zone. Here we discuss its design, installation, and first results. We conclude that, despite the logistical challenges and installation costs, the superior quality of downhole data puts this technique at the forefront of applied and fundamental research.

  2. Does drywall installers' innovative idea reduce the ergonomic exposures of ceiling installation: A field case study.

    PubMed

    Dasgupta, Priyadarshini Sengupta; Punnett, Laura; Moir, Susan; Kuhn, Sarah; Buchholz, Bryan

    2016-07-01

    The study was conducted to assess an intervention suggested by the workers to reduce the physical or ergonomic exposures of the drywall installation task. The drywall installers were asked to brainstorm on innovative ideas that could reduce their ergonomic exposures during the drywall installation work. The workers proposed the idea of using a 'deadman' (narrow panel piece) to hold the panels to the ceiling while installing them. The researcher collected quantitative exposure data (PATH, 3DSSPP) at the baseline and intervention phases and compared the phases to find out any change in the exposure while using the 'deadman'. Results showed that ergonomic exposures (such as overhead arm and awkward trunk postures and heavy load handling) were reduced at the intervention phase while using the 'deadman' with an electrically operated lift. The concept of the 'deadman', which was shown to help reduce musculoskeletal exposures during ceiling installation, can be used to fabricate a permanent ergonomic tool to support the ceiling drywall panel. Copyright © 2016 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  3. Installed Base Registration of Decentralised Solar Panels with Applications in Crisis Management

    NASA Astrophysics Data System (ADS)

    Aarsen, R.; Janssen, M.; Ramkisoen, M.; Biljecki, F.; Quak, W.; Verbree, E.

    2015-08-01

    In case of a calamity in the Netherlands - e.g. a dike breach - parts of the nationwide electric network can fall out. In these occasions it would be useful if decentralised energy sources of the Smart Grid would contribute to balance out the fluctuations of the energy network. Decentralised energy sources include: solar energy, wind energy, combined heat and power, and biogas. In this manner, parts of the built environment - e.g. hospitals - that are in need of a continuous power flow, could be secured of this power. When a calamity happens, information about the Smart Grid is necessary to control the crisis and to ensure a shared view on the energy networks for both the crisis managers and network operators. The current situation of publishing, storing and sharing data of solar energy has been shown a lack of reliability about the current number, physical location, and capacity of installed decentralised photovoltaic (PV) panels in the Netherlands. This study focuses on decentralised solar energy in the form of electricity via PV panels in the Netherlands and addresses this challenge by proposing a new, reliable and up-to-date database. The study reveals the requirements for a registration of the installed base of PV panels in the Netherlands. This new database should serve as a replenishment for the current national voluntary registration, called Production Installation Register of Energy Data Services Netherland (EDSN-PIR), of installed decentralised PV panel installations in the Smart Grid, and provide important information in case of a calamity.

  4. Characterization Of Station Quality From The CHILE RAMP Deployment - Direct Burial Sensor Installation And Its Data

    NASA Astrophysics Data System (ADS)

    Arias, E. Y.; Beaudoin, B. C.; Barstow, N.; Slad, G.

    2010-12-01

    IRIS PASSCAL supported a NSF-funded project to collect an open community dataset from a portable seismograph deployment following the magnitude 8.8 earthquake that occurred off the coast of Chile on February 27, 2010 (an experiment of the Rapid Array Mobilization Program - RAMP). In part, due to logistical constraints, the broadband sensors (Guralp CMG3T) for this deployment were buried directly in soil. Direct burial refers to installation of a broadband sensor in a small hand-dug hole, encased in plastic bags, and ideally backfilled with well tamped and dampened sand. Field conditions did not provide ideal installations in all cases. Because of the variability in actual installation practices, the Chile RAMP data provide an opportunity to examine the impact of several factors on the direct burial data quality. Using McNamara and Boaz (2005) PQLX statistical analysis software, which calculates the power spectral density (PSD) and plots the probability density function (PDF)(McNamara and Buland, 2004), we characterize the background seismic noise levels and signal quality for 58 directly buried installations at the Chile RAMP. Data return and data quality during the deployment (April -September 2010) will be evaluated considering a variety of parameters including installation technique, site characteristics, and equipment performance. Preliminary results using data from two service runs (April - June), suggest variation in the data quality and recovery due to slightly different installation practices and/or possibly environmental factors. We seek to evaluate and characterize parameters that affect the resulting data recovery and their quality; this study is an important test case for future PASSCAL and RAMP installations. If possible we would like to compare data from other local networks to identify distinctive characteristics from different installation set-ups.

  5. 40 CFR 147.1955 - Requirements for wells authorized by permit.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (ii) Cemented back to the surface by recirculating the cement; and (2) Long string casing and tubing... volume. (3) For new enhanced recovery wells, install tubing or long string casing extending to the injection zone. (4) For new salt water disposal wells, install long string casing and tubing extending to...

  6. Case Study: Fuel Cells Provide Combined Heat and Power at Verizon's Garden City Central Office

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2010-12-01

    This case study describes how Verizon's Central Office in Garden City, NY, installed a 1.4-MW phosphoric acid fuel cell system as an alternative solution to bolster electric reliability, optimize the company's energy use, and reduce costs in an environmentally responsible manner.

  7. The choice of primary energy source including PV installation for providing electric energy to a public utility building - a case study

    NASA Astrophysics Data System (ADS)

    Radomski, Bartosz; Ćwiek, Barbara; Mróz, Tomasz M.

    2017-11-01

    The paper presents multicriteria decision aid analysis of the choice of PV installation providing electric energy to a public utility building. From the energy management point of view electricity obtained by solar radiation has become crucial renewable energy source. Application of PV installations may occur a profitable solution from energy, economic and ecologic point of view for both existing and newly erected buildings. Featured variants of PV installations have been assessed by multicriteria analysis based on ANP (Analytic Network Process) method. Technical, economical, energy and environmental criteria have been identified as main decision criteria. Defined set of decision criteria has an open character and can be modified in the dialog process between the decision-maker and the expert - in the present case, an expert in planning of development of energy supply systems. The proposed approach has been used to evaluate three variants of PV installation acceptable for existing educational building located in Poznań, Poland - the building of Faculty of Chemical Technology, Poznań University of Technology. Multi-criteria analysis based on ANP method and the calculation software Super Decisions has proven to be an effective tool for energy planning, leading to the indication of the recommended variant of PV installation in existing and newly erected public buildings. Achieved results show prospects and possibilities of rational renewable energy usage as complex solution to public utility buildings.

  8. Reducing Propulsion Airframe Aeroacoustic Interactions with Uniquely Tailored Chevrons. 2; Installed Nozzles

    NASA Technical Reports Server (NTRS)

    Mengle, Vinod G.; Elkoby, Ronen; Brusniak, Leon; Thomas, Russ H.

    2006-01-01

    Propulsion airframe aeroacoustic (PAA) interactions arise due to the manner in which an engine is installed on the airframe and lead to an asymmetry in the flow/acoustic environment, for example, for under-the-wing installations due to the pylon, the wing and the high-lift devices. In this work we study how we can affect these PAA interactions to reduce the overall jet-related installed noise by tailoring the chevron shapes on fan and core nozzles in a unique fashion to take advantage of this asymmetry. In part 1 of this trio of papers we introduced the concept of azimuthally varying chevrons (AVC) and showed how some types of AVCs can be more beneficial than the conventional chevrons when tested on "isolated" scaled nozzles inclusive of the pylon effect. In this paper, we continue to study the effect of installing these AVC nozzles under a typical scaled modern wing with high-lift devices placed in a free jet. The noise benefits of these installed nozzles, as well as their installation effects are systematically studied for several fan/core AVC combinations at typical take-off conditions with high bypass ratio. We show, for example, that the top-enhanced mixing T-fan AVC nozzle (with enhanced mixing near the pylon and less mixing away from it) when combined with conventional chevrons on the core nozzle is quieter than conventional chevrons on both nozzles, and hardly produces any high-frequency lift, just as in the isolated case; however, its installed nozzle benefit is less than its isolated nozzle benefit. This suppression of take-off noise benefit under installed conditions, compared to its isolated nozzle benefit, is seen for all other chevron nozzles. We show how these relative noise benefits are related to the relative installation effects of AVCs and baseline nozzles.

  9. Casing pipe damage detection with optical fiber sensors: a case study in oil well constructions

    NASA Astrophysics Data System (ADS)

    Zhou, Zhi; He, Jianping; Huang, Minghua; He, Jun; Ou, Jinping; Chen, Genda

    2010-04-01

    Casing pipes in oil well constructions may suddenly buckle inward as their inside and outside hydrostatic pressure difference increases. For the safety of construction workers and the steady development of oil industries, it is critically important to measure the stress state of a casing pipe. This study develops a rugged, real-time monitoring, and warning system that combines the distributed Brillouin Scattering Time Domain Reflectometry (BOTDR) and the discrete fiber Bragg grating (FBG) measurement. The BOTDR optical fiber sensors were embedded with no optical fiber splice joints in a fiber reinforced polymer (FRP) rebar and the FBG sensors were wrapped in epoxy resins and glass clothes, both installed during the segmental construction of casing pipes. In-situ tests indicate that the proposed sensing system and installation technique can survive the downhole driving process of casing pipes, withstand a harsh service environment, and remain in tact with the casing pipes for compatible strain measurements. The relative error of the measured strains between the distributed and discrete sensors is less than 12%. The FBG sensors successfully measured the maximum horizontal principal stress with a relative error of 6.7% in comparison with a cross multi-pole array acoustic instrument.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giles, Carrie; Ryder, Carrie; Lommele, Stephen

    This case study features the experiences of university partners in the U.S. Department of Energy's (DOE) Workplace Charging Challenge with the installation and management of plug-in electric vehicle (PEV) charging stations.

  11. Case study comparison of two pellet heating facilities in southeastern Alaska

    Treesearch

    David Nicholls; Allen Brackley; Robert Deering; Daniel Parrent; Brian Kleinhenz; Craig. Moore

    2016-01-01

    Over the past decade, wood-energy use in Alaska has grown dramatically. Since 2000, several dozen new wood-energy installations have been established, with numerous others in the design or construction phase. This case study report compares two wood-pellet heating systems in Juneau, Alaska. The Tlingit-Haida Regional Housing Authority, a native housing authority that...

  12. Overview of the experimental tests in prototype

    NASA Astrophysics Data System (ADS)

    Egusquiza, Eduard; Valentín, David; Presas, Alexandre; Valero, Carme

    2017-04-01

    Experimental tests in prototype are necessary to understand the dynamic behaviour of the machine during different operating points. Hydraulic phenomena as well as its effect on the structure need to be studied in order to avoid instabilities during operation and to extend the life-time of the different components. For this purpose, a complete experimental study of a large Francis turbine prototype has been performed installing several sensors along the machine. Pressure sensors were installed in the penstock, spiral case, runner and draft tube, strain gauges were installed in the runner, vibration sensors were used in the stationary parts and different electrical and operational parameters were also measured. All these signals were acquired simultaneously for different operating points of the turbine.

  13. 'Worst case' methodology for the initial assessment of societal risk from proposed major accident installations.

    PubMed

    Carter, D A; Hirst, I L

    2000-01-07

    This paper considers the application of one of the weighted risk indicators used by the Major Hazards Assessment Unit (MHAU) of the Health and Safety Executive (HSE) in formulating advice to local planning authorities on the siting of new major accident hazard installations. In such cases the primary consideration is to ensure that the proposed installation would not be incompatible with existing developments in the vicinity, as identified by the categorisation of the existing developments and the estimation of individual risk values at those developments. In addition a simple methodology, described here, based on MHAU's "Risk Integral" and a single "worst case" even analysis, is used to enable the societal risk aspects of the hazardous installation to be considered at an early stage of the proposal, and to determine the degree of analysis that will be necessary to enable HSE to give appropriate advice.

  14. Systems analysis of the installation, mounting, and activation of emergency locator transmitters in general aviation aircraft

    NASA Technical Reports Server (NTRS)

    Hall, D. S.

    1980-01-01

    A development program was developed to design and improve the Emergency Locator Transmitter (ELT) transmitter and to improve the installation in the aircraft and its activation subsystem. There were 1135 general aviation fixed wing aircraft accident files reviewed. A detailed description of the damage to the aircraft was produced. The search aspects of these accidents were studied. As much information as possible about the ELT units in these cases was collected. The data should assist in establishing installation and mounting criteria, better design standards for activation subsystems, and requirements for the new ELT system design in the area of crashworthiness.

  15. Department of Defense Base Reuse Implementation Manual, DOD 4165.66-M

    DTIC Science & Technology

    1997-12-01

    applications? SPECIAL CONSIDERATION In the case of representatives of the homeless whose applications have been approved by HHS under Title V of the...2) In the case of installations approved for closure under a base closure law before the date of the enactment of this Act, not later than 15 days...realignment, as the case may be, of such installation under the applicable base closure law expires. (3) The term "redevelopment authority", in the case

  16. Minimization of the energy storage requirements of a stand-alone wind power installation by means of photovoltaic panels

    NASA Astrophysics Data System (ADS)

    Kaldellis, J. K.; Kostas, P.; Filios, A.

    2006-07-01

    Autonomous wind power systems are among the most interesting and environmentally friendly technological solutions for the electrification of remote consumers. In many cases, however, the battery contribution to the initial or the total operational cost is found to be dominant, discouraging further penetration of the available wind resource. This is basically the case for areas possessing a medium-low wind potential. On the other hand, several isolated consumers are located in regions having the regular benefit of an abundant and reliable solar energy supply. In this context the present study investigates the possibility of reducing the battery size of a stand-alone wind power installation by incorporating a small photovoltaic generator. For this purpose an integrated energy production installation based exclusively on renewable energy resources is hereby proposed. Subsequently a new numerical algorithm is developed that is able to estimate the appropriate dimensions of a similar system. According to the results obtained by long-term experimental measurements, the introduction of the photovoltaic panels considerably improves the operational and financial behaviour of the complete installation owing to the imposed significant battery capacity diminution. Copyright

  17. Industrial application of low voltage bidirectional automatic release of reserve

    NASA Astrophysics Data System (ADS)

    Popa, G. N.; Diniş, C. M.; Iagăr, A.; Deaconu, S. I.; Popa, I.

    2018-01-01

    The paper presents an analysis on low voltage industrial electrical installation controlled by bidirectional automatic release of reserve. Industrial electrical installation is for removing smoke in case of fire from a textile company. The main parts of the installation of removing smoke in case of fire are: general electrical panel; reserve electrical panel; three-phase induction motors for driven fans; electrical actuators for inlet and outlet valves; clean air inlet pipe, respectively, the outlet pipe for smoke. The operation and checking of bidirectional automatic release of reserve are present in the paper.

  18. 76 FR 37247 - Airworthiness Directives; Learjet Inc. Model 45 Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-27

    ... the left engine accessory compartment, and corrective actions if necessary. This new AD also requires...) Replace the left engine fuel and hydraulic tubing and install a tubing support channel using new parts. (2... other damage of the case drain tube from the hydraulic pump case installed on the left-hand engine, and...

  19. Acoustic and other factors relating to the use of sound field systems in classrooms

    NASA Astrophysics Data System (ADS)

    Carey, Anne; Shield, Bridget; Dockrell, Julie; Rigby, Kate

    2005-04-01

    A study has been made of thirty-five primary school classrooms which have Sound Field Systems (SFS) installed. Acoustic surveys of the classrooms have been undertaken and detailed observations made of the physical characteristics of each room such as its construction and design, plus any acoustic treatment. The positioning and type, e.g., column or separate speakers, of SFS installed were also noted. Details of the procedures for purchasing, installing, and maintaining the SFS were obtained where possible, together with information concerning training of teachers in their use. Results from these surveys suggest that in many cases SFS are installed in rooms where their performance may be compromised because of inadequate acoustic conditions. Additionally problems may arise due to inappropriate installation, choice of system, poor maintenance, or lack of training. The effectiveness of acoustic treatment such as absorption applied to ceilings and walls has also been investigated in a range of classrooms and its impact on the use of SFS considered.

  20. Apparatus for installing condition-sensing means in subterranean earth formations

    DOEpatents

    Shuck, Lowell Z.

    1981-01-01

    The present invention is directed to an apparatus for installing strain gages or other sensors-transducers in wellbores penetrating subterranean earth formations. The subject apparatus comprises an assembly which is lowered into the wellbore, secured in place, and then actuated to sequentially clean the wellbore or casing surface at a selected location with suitable solvents, etchants and neutralizers, grind the surface to a relatively smooth finish, apply an adhesive to the surface, and attach the strain gages or the like to the adhesive-bearing surface. After installing the condition-sensing gages to the casing or earth formation the assembly is withdrawn from the wellbore leaving the sensing gages securely attached to the casing or the subterranean earth formation.

  1. Groundwater data for selected wells within the Eastern San Joaquin Groundwater Subbasin, California, 2003-8

    USGS Publications Warehouse

    Clark, Dennis A.; Izbicki, John A.; Metzger, Loren F.; Everett, Rhett; Smith, Gregory A.; O'Leary, David R.; Teague, Nicholas F.; Burgess, Matthew K.

    2012-01-01

    Data were collected by the U.S. Geological Survey from 2003 through 2008 in the Eastern San Joaquin Groundwater Subbasin, 80 miles east of San Francisco, California, as part of a study of the increasing chloride concentrations in groundwater processes. Data collected include geologic, geophysical, chemical, and hydrologic data collected during and after the installation of five multiple-well monitoring sites, from three existing multiple-well sites, and from 79 selected public-supply, irrigation, and domestic wells. Each multiple-well monitoring site installed as part of this study contained three to five 2-inch diameter polyvinyl chloride (PVC)-cased wells ranging in depth from 68 to 880 feet below land surface. Continuous water-level data were collected from the 19 wells installed at these 5 sites and from 10 existing monitoring wells at 3 additional multiple-well sites in the study area. Thirty-one electromagnetic logs were collected seasonally from the deepest PVC-cased monitoring well at seven multiple-well sites. About 200 water samples were collected from 79 wells in the study area. Coupled well-bore flow data and depth-dependent water-quality data were collected from 12 production wells under pumped conditions, and well-bore flow data were collected from 10 additional wells under unpumped conditions.

  2. 27 CFR 53.99 - Sales of installment accounts.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 2 2012-04-01 2011-04-01 true Sales of installment... AMMUNITION Special Provisions Applicable to Manufacturers Taxes § 53.99 Sales of installment accounts. (a) In general. Except as provided in paragraph (d) of this section, in case of a sale or other disposition by a...

  3. Business Case Analysis of the Marine Corps Base Pendleton Virtual Smart Grid

    DTIC Science & Technology

    2017-06-01

    Metering Infrastructure on DOD installations. An examination of five case studies highlights the costs and benefits of the Virtual Smart Grid (VSG...studies highlights the costs and benefits of the Virtual Smart Grid (VSG) developed by Space and Naval Warfare Systems Command for use at Marine Corps...41 A. SMART GRID BENEFITS .....................................................................41 B. SUMMARY OF VSG ESTIMATED COSTS AND BENEFITS

  4. Sonic Onyx: Case Study of an Interactive Artwork

    NASA Astrophysics Data System (ADS)

    Ahmed, Salah Uddin; Jaccheri, Letizia; M'kadmi, Samir

    Software supported art projects are increasing in numbers in recent years as artists are exploring how computing can be used to create new forms of live art. Interactive sound installation is one kind of art in this genre. In this article we present the development process and functional description of Sonic Onyx, an interactive sound installation. The objective is to show, through the life cycle of Sonic Onyx, how a software dependent interactive artwork involves its users and raises issues related to its interaction and functionalities.

  5. Reliability of excess-flow check-valves in turbine lubrication systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dundas, R.E.

    1996-12-31

    Reliability studies on excess-flow check valves installed in a gas turbine lubrication system for prevention of spray fires subsequent to fracture or separation of lube lines were conducted. Fault-tree analyses are presented for the case of failure of a valve to close when called upon by separation of a downstream line, as well as for the case of accidental closure during normal operation, leading to interruption of lubricating oil flow to a bearing. The probabilities of either of these occurrences are evaluated. The results of a statistical analysis of accidental closure of excess-flow check valves in commercial airplanes in themore » period 1986--91 are also given, as well as a summary of reliability studies on the use of these valves in residential gas installations, conducted under the sponsorship of the Gas Research Institute.« less

  6. Posthole Broadband Sensor Emplacement vs. Surface Vaults: Observations of Comparative Noise Performance and Trade-offs

    NASA Astrophysics Data System (ADS)

    Sweet, J. R.; Beaudoin, B. C.; Barstow, N.; Pfeifer, M.; Anderson, K. R.; Frassetto, A.

    2015-12-01

    Advances in seismometer design have diversified the range of instruments available for use in temporary field installations. IRIS programs, primarily PASSCAL and the Transportable Array (TA), have helped steer development of these new instruments to meet these evolving needs. PASSCAL operates a small pool of posthole broadband sensors, purpose built for direct burial. Near surface posthole installations are a new, cost effective, and logistically simple technique for broadband emplacement that is an alternative to the vault installations used in portable broadband seismic experiments for nearly 30 years. Direct burial installation is limited to the time and effort required to dig the borehole and emplace the sensor, thus reducing both material costs and time to install. Also, in Alaska, extreme environments and difficult logistics make standard TA tank vaults inappropriate for most sites. TA has developed improved deployment strategies for these environments. There, holes for posthole sensors are hammer- drilled or augered to several meters depth in soil, permafrost, or bedrock and then cased. These emplacement costs are generally less than standard TA vaults. We compare various installation techniques for test cases as well as general deployments of PASSCAL and TA stations. Automated noise performance analyses have been part of the TA throughout its operation, but until recently vault performance for portable installations supported by the PASSCAL program was sparse. In this study, we select a suite of co-located direct burial and surface vault installations and compare their noise performance using probability density functions. Our initial analyses suggest that direct burial sensors have lower noise levels than vault installations on both horizontal and vertical channels across a range of periods spanning <1 s to 100 s. However, most of these initial experiments for PASSCAL were with sensors not purpose built for direct burial and it became obvious that a sensor designed for direct burial was necessary. For the TA, direct emplacement of purpose-built sensors has routinely improved noise levels, particularly beyond about 20 s, by tens of dB. These results suggest that moving towards an instrument pool composed primarily of purpose-built direct burial sensors could yield higher-quality data at lower cost.

  7. Core curriculum illustration: rib fractures.

    PubMed

    Dunham, Gregor M; Perez-Girbes, Alexandre; Linnau, Ken F

    2017-06-01

    This is the 24th installment of a series that will highlight one case per publication issue from the bank of cases available online as part of the American Society of Emergency Radiology (ASER) educational resources. Our goal is to generate more interest in and use of our online materials. To view more cases online, please visit the ASER Core Curriculum and Recommendations for Study online at http://www.aseronline.org/curriculum/toc.htm .

  8. Description of piezometers installed in the middle Rio Grande basin area, 1997-99, central New Mexico

    USGS Publications Warehouse

    Bartolino, J.R.; Rankin, D.R.

    2000-01-01

    Since 1993, the Santa Fe Group aquifer system in the Middle Rio Grande Basin, and particularly in the Albuquerque area, has been the focus of studies to further define the extent of the most productive parts of the aquifer and to gain a better understanding of how ground- water levels are changing over time. The U.S. Geological Survey, in cooperation with the New Mexico Office of the State Engineer, installed nine piezometers during 1998-99 at five sites in and near the margin of the Middle Rio Grande Basin in central New Mexico. In addition, the New Mexico Office of the State Engineer installed another nine piezometers at three sites during 1997. These piezometers allow for collection of ground-water-level data in areas for which little information is available. Most of the piezometers were constructed of 2.5-inch-diameter flush-joint polyvinyl chloride (PVC) schedule 80 casing with 10-foot stainless steel screens; the shallow piezometer at the Tome site has a 40-foot screen, and the single piezometers at the Dome Road and Phoenix Road sites have steel casing with welded joints and a 10- and a 20-foot screen, respectively. Steel casing with a locking lid covers the uppermost 2 feet of the piezometer casing. Drillers' logs and petrophysical logs were collected from the deepest borehole at each site.

  9. 26 CFR 48.4216(d)-1 - Sales of installment accounts.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 16 2011-04-01 2011-04-01 false Sales of installment accounts. 48.4216(d)-1... Manufacturers Taxes § 48.4216(d)-1 Sales of installment accounts. (a) In general. Except as provided in paragraph (d) of this section, in case of a sale or other disposition by a manufacturer, producer, or...

  10. 26 CFR 48.4216(d)-1 - Sales of installment accounts.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Sales of installment accounts. 48.4216(d)-1... Manufacturers Taxes § 48.4216(d)-1 Sales of installment accounts. (a) In general. Except as provided in paragraph (d) of this section, in case of a sale or other disposition by a manufacturer, producer, or...

  11. 78 FR 57253 - Airworthiness Directives; Honeywell ASCa Inc. Emergency Locator Transmitters Installed on Various...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-18

    ... detect and correct discrepancies of the battery wiring installation inside the TU, which could result in... TUs revealed battery wiring installation discrepancies inside the TU that may result in an electrical short. The AAIB noted that in case of an electrical short, the ELT battery could provide the energy for...

  12. Volumetric change of silts following cyclic loading.

    DOT National Transportation Integrated Search

    2013-06-01

    Estimating the settlement of adjacent structures during pile installation in silts is a challenging problem for : practicing engineers. The current state-of-practice relies primarily on local case studies and monitoring efforts, such as : inclinomete...

  13. State Grade Crossing Programs : A Case Study

    DOT National Transportation Integrated Search

    1974-09-01

    This report reviews the California Railroad-Highway Grade Crossing Program, analyzing the factors influencing the reduction in grade crossing accidents. The repor concludes that the greater than average success in grade crossing installation and main...

  14. The National Model for Minority Education and Training Demonstration (NMMETD) Case Study

    EPA Pesticide Factsheets

    NMMETD targeted minority and indigent residents by educating homeowners about the management of onsite systems and assisting residents with funding options for managing, installing, and disseminating information about onsite wastewater systems.

  15. Energy information data base: report number codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1979-09-01

    Each report processed by the US DOE Technical Information Center is identified by a unique report number consisting of a code plus a sequential number. In most cases, the code identifies the originating installation. In some cases, it identifies a specific program or a type of publication. Listed in this publication are all codes that have been used by DOE in cataloging reports. This compilation consists of two parts. Part I is an alphabetical listing of report codes identified with the issuing installations that have used the codes. Part II is an alphabetical listing of installations identified with codes eachmore » has used. (RWR)« less

  16. DAMS: A Model to Assess Domino Effects by Using Agent-Based Modeling and Simulation.

    PubMed

    Zhang, Laobing; Landucci, Gabriele; Reniers, Genserik; Khakzad, Nima; Zhou, Jianfeng

    2017-12-19

    Historical data analysis shows that escalation accidents, so-called domino effects, have an important role in disastrous accidents in the chemical and process industries. In this study, an agent-based modeling and simulation approach is proposed to study the propagation of domino effects in the chemical and process industries. Different from the analytical or Monte Carlo simulation approaches, which normally study the domino effect at probabilistic network levels, the agent-based modeling technique explains the domino effects from a bottom-up perspective. In this approach, the installations involved in a domino effect are modeled as agents whereas the interactions among the installations (e.g., by means of heat radiation) are modeled via the basic rules of the agents. Application of the developed model to several case studies demonstrates the ability of the model not only in modeling higher-level domino effects and synergistic effects but also in accounting for temporal dependencies. The model can readily be applied to large-scale complicated cases. © 2017 Society for Risk Analysis.

  17. PERFORMANCE GOALS CASE STUDY: ELIZABETH CITY, NC

    EPA Science Inventory

    Permeable reactive barriers (PRB's) are an emerging, alternative in-situ approach for remediating groundwater contamination that combine subsurface fluid flow management with a passive chemical treatment zone. The few pilot and commercial installations which have been implemented...

  18. The potential for PVs in Greek commercial buildings

    NASA Astrophysics Data System (ADS)

    Samouil, Chris

    The photovoltaic sector has been growing explosively, worldwide, for the past few years. At present, grid-connected installations dominate the world market. The photovoltaic technology, types of systems, applications and the market of PVs are presented, placing emphasis on installations regarding the building sector. The main focus of the project is concentrated on Greece. The fact that Greece has favourable natural conditions for the exploitation of solar energy, coupled with the support scheme on phototovoltaics introduced with the new law on renewable energy sources voted in June 2006, makes it very interesting to invest in the Greek PV market. Using a newly built office building in Athens with a roof-top PV installation as a case study, this project looks at the viability of grid-connected systems in the building sector. The annual energy output of the system and CO2 emissions reduction were modelled. Embodied energy, installation cost and annual savings were also considered to determine payback periods. The economic payback period of the system was found to be shorter than its lifetime at 16.2 years, reducing to 9.7 years when grants were included. The carbon payback period was calculated at 6.3 years. A sensitivity analysis on the effect of different factors affecting the viability of the PV installation was carried out. Assuming constant electricity rate increases or a more favourable location for the project the results are more attractive. The same case study in Crete would have a payback period reduced by almost 20% compared to that in Athens. A method to extrapolate the findings for the whole building sector of Attica is proposed as a future research project. As an indication it is found that 60,000 similar to the base case roof-top PV systems can produce around 3.1% of the country's thermally produced electricity and save 0.9% of its CO2 emissions. Finally, the strengths and weeknesses of the new RES law are identified and suggestions are made in order to smoothen PV implementation in Greece.

  19. ASER core curriculum illustration project: aortic intramural hematoma (IMH).

    PubMed

    Perez-Girbes, Alexandre; Dunham, Gregor M; Linnau, Ken F

    2017-04-01

    This is the 23rd installment of a series that will highlight one case per publication issue from the bank of cases available online as part of the American Society of Emergency Radiology (ASER) educational resources. Our goal is to generate more interest in and use of our online materials. To view more cases online, please visit the ASER Core Curriculum and Recommendations for Study online at http://www.aseronline.org/curriculum/toc.htm .

  20. Hurdling barriers through market uncertainty: Case studies ininnovative technology adoption

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Payne, Christopher T.; Radspieler Jr., Anthony; Payne, Jack

    The crisis atmosphere surrounding electricity availability in California during the summer of 2001 produced two distinct phenomena in commercial energy consumption decision-making: desires to guarantee energy availability while blackouts were still widely anticipated, and desires to avoid or mitigate significant price increases when higher commercial electricity tariffs took effect. The climate of increased consideration of these factors seems to have led, in some cases, to greater willingness on the part of business decision-makers to consider highly innovative technologies. This paper examines three case studies of innovative technology adoption: retrofit of time-and-temperature signs on an office building; installation of fuel cellsmore » to supply power, heating, and cooling to the same building; and installation of a gas-fired heat pump at a microbrewery. We examine the decision process that led to adoption of these technologies. In each case, specific constraints had made more conventional energy-efficient technologies inapplicable. We examine how these barriers to technology adoption developed over time, how the California energy decision-making climate combined with the characteristics of these innovative technologies to overcome the barriers, and what the implications of hurdling these barriers are for future energy decisions within the firms.« less

  1. Installed Transonic 2D Nozzle Nacelle Boattail Drag Study

    NASA Technical Reports Server (NTRS)

    Malone, Michael B.; Peavey, Charles C.

    1999-01-01

    The Transonic Nozzle Boattail Drag Study was initiated in 1995 to develop an understanding of how external nozzle transonic aerodynamics effect airplane performance and how strongly those effects are dependent on nozzle configuration (2D vs. axisymmetric). MDC analyzed the axisymmetric nozzle. Boeing subcontracted Northrop-Grumman to analyze the 2D nozzle. AU participants analyzed the AGARD nozzle as a check-out and validation case. Once the codes were checked out and the gridding resolution necessary for modeling the separated flow in this region determined, the analysis moved to the installed wing/body/nacelle/diverter cases. The boat tail drag validation case was the AGARD B.4 rectangular nozzle. This test case offered both test data and previous CFD analyses for comparison. Results were obtained for test cases B.4.1 (M=0.6) and B.4.2 (M=0.938) and compared very well with the experimental data. Once the validation was complete a CFD grid was constructed for the full Ref. H configuration (wing/body/nacelle/diverter) using a combination of patched and overlapped (Chimera) grids. This was done to ensure that the grid topologies and density would be adequate for the full model. The use of overlapped grids allowed the same grids from the full configuration model to be used for the wing/body alone cases, thus eliminating the risk of grid differences affecting the determination of the installation effects. Once the full configuration model was run and deemed to be suitable the nacelle/diverter grids were removed and the wing/body analysis performed. Reference H wing/body results were completed for M=0.9 (a=0.0, 2.0, 4.0, 6.0 and 8.0), M=1.1 (a=4.0 and 6.0) and M=2.4 (a=0.0, 2.0, 4.4, 6.0 and 8.0). Comparisons of the M=0.9 and M=2.4 cases were made with available wind tunnel data and overall comparisons were good. The axi-inlet/2D nozzle nacelle was analyzed isolated. The isolated nacelle data coupled with the wing/body result enabled the interference effects of the installed nacelles to be determined. Isolated nacelle mm were made at M=0.9 and M=1.1 for both the supersonic and transonic nozzle settings. AU of the isolated nacelle cases were run at alpha=0. Full configuration runs were to be made at Mach numbers of 0.9, 1.1, and 2.4 (the same as the wing/body and isolated nacelles). Both the isolated nacelles and installed nacelles were run with inlet conditions designed to give zero spillage. This was to be done in order to isolate the boattail effects as much as possible. Full configuration runs with the supersonic nozzles were completed for M=0.9 and 1.1 at a=4.0 and 6.0 (4 runs total) and with the transonic nozzles at M=0.9 and 1.1 at a=2.0, 4.0 and 6.0 (6 runs total). Drag breakdowns were completed for the M=0.9 and M= 1.1 showing favorable interference drag for both cases.

  2. Case studies of soil in art

    NASA Astrophysics Data System (ADS)

    Feller, C.; Landa, E. R.; Toland, A.; Wessolek, G.

    2015-08-01

    The material and symbolic appropriations of soil in artworks are numerous and diverse, spanning many centuries and artistic traditions, from prehistoric painting and ceramics to early Renaissance works in Western literature, poetry, paintings, and sculpture, to recent developments in film, architecture, and contemporary art. Case studies focused on painting, installation, and film are presented with the view of encouraging further exploration of art about, in, and with soil as a contribution to raising soil awareness.

  3. Fiberglass distribution poles: A case study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, M.F.; Hosford, G.S.; Boozer, J.F. III

    1995-01-01

    This paper addresses the design considerations and manufacturing techniques along with mechanical test results of fiberglass reinforced composite (FRC) primary distribution poles. With it`s light weight, and virtually no maintenance it offers a viable alternative for use in remote and inaccessible locations. This paper also discusses a case study where seventy five FRC primary distribution poles have been installed on a distribution system in a remote area accessible only by foot and helicopter.

  4. An Evaluation of Installation Methods for STS-1 Seismometers

    USGS Publications Warehouse

    Holcomb, L. Gary; Hutt, Charles R.

    1992-01-01

    INTRODUCTION This report documents the results of a series of experiments conducted by the authors at the Albuquerque Seismological Laboratory (ASl) during the spring and summer of 1991; the object of these experiments was to obtain and document quantitative performance comparisons of three methods of installing STS-1 seismometers. Historically, ASL has installed STS-1 sensors by cementing their thick glass base plates to the concrete floor of the vault (see Peterson and Tilgner, 1985, p 44 and Figure 31, p 51 for the details of this installation technique). This installation technique proved to be fairly satisfactory for the China Digital Seismic Network and for several sets of STS-1 sensors installed in other locations since that time. However, the cementing operation is rather labor intensive and the concrete requires a lengthy (about 1 week) curing time during which the sensor installed on it is noisy. In addition it is difficult to assure that all air bubbles have been removed from the interface between the cement and the glass base plate. If air bubbles are present beneath the plate, horizontal sensors can be unacceptably noisy. Moving a sensor installed in this manner requires the purchase of a new glass base plate because the old plate normally can not be removed without breakage. Therefore, this study was undertaken with the aim of developing an improved method of installing STS-1's. The goals were to develop a method which requires less field site labor during the installation and assures a higher quality installation when finished. In addition, the improved installation technique should promote portability. Two alternate installation techniques were evaluated in this study. One method replaces the cement between the base plate and the vault floor with sand. This method has been used in the French Geoscope program and in several IRIS/IDA installations made by the University of California at San Diego (UCSD) and possibly others. It is easily implemented in the field and is quite cheap. The other method utilizes a so called warpless housing designed by E. Wielandt and implemented at ASL. This housing is quite similar to the case design of the STS-2 sensor system. It is designed to minimize the effects of atmospheric pressure variations on the sealed housing.

  5. Mitigating contaminant transport in utility installation.

    DOT National Transportation Integrated Search

    2003-01-01

    In recent years, the Virginia Department of Transportation (VDOT) has experienced problems with various forms of contamination (primarily from underground storage tanks, USTs) migrating into its right-of-way. In many cases VDOT has had to install cul...

  6. The utilization of automated external defibrillators in Taiwan.

    PubMed

    Wang, Tsung-Hsi; Wu, Hsi-Wen; Hou, Peter C; Tseng, Hao-Jui

    2018-03-24

    Increasing attention to care of patient succumbed to out-of-hospital cardiac arrest (OHCA) and evidence for improved survival have resulted in many countries to encourage the use automated external defibrillators (AEDs) by legislation. In Taiwan, the amendment of the Emergency Medical Services Act mandated the installation of AEDs in designated areas in 2013. Since then, 6151 AEDs have been installed and registered in mandated and non-mandated locations. The purpose of this study was to investigate the utilization of AEDs at mandated and non-mandated locations. This paper analyzed 217 cases in whom AEDs was used between July 11, 2013 and July 31, 2015. Descriptive statistics were used to analyze the data. The highest frequency of AEDs used was in long-term care facilities, accounting for 34 (15.7%) cases. The second and third highest was in schools and commuting stations. The highest utilization rate of registered AED was in long-term care facilities (73.9%), the second was in residential areas, and the third was in hot spring areas. Employees at the designated locations or medical personnel operated the AED in 143 cases (84.6%), and bystanders, relatives, friends or others operated the AEDs in 26 cases (15.4%). On-site Return of Spontaneous Circulation (ROSC) after applying AEDs occurred in 76 cases (45.8%). Long-term care facilities had the highest utilization of AEDs and government should pay more attention to enforce the installing of AEDs in these places. The government also needs to promote the education public on how to search the AEDs locations. Copyright © 2018. Published by Elsevier B.V.

  7. Trillium Horizon, A Small Portable Observatory Grade Seismometer For Direct Bury And Vault Use

    NASA Astrophysics Data System (ADS)

    Moores, A.; Parker, T.; Bainbridge, G.

    2017-12-01

    As of August 2017 almost 5 years of data have been collected from broadband seismic sensors designed for direct burial applications. These first posthole instruments have been deployed in a wide range of extremely challenging environments such as dynamic ice and snow environments, extreme wet and dry conditions in soils of high clay content, and steep creeping terrain. In all use cases the direct burial approach has consistently provided high quality data when compared to shallow vault installations. In this presentation we extract and analyze operational performance data, including tilt information from mass position time series recorded at direct burial installations and at temporary shallow vault deployments. This data shows that while higher tilt tolerance is required for data quality outcome certainty in some installations, the majority of installations can be addressed by a smaller instrument with a narrower tilt range hence reducing size and cost. The lessons learned from this real world field data have guided the development of a new smaller, less expensive instrument, Trillium Horizon.Based on this analysis and and user feedback from many direct burial deployments, the Trillium Horizon seismometer has been developed as a simple versatile instrument to span the majority of deployment scenarios and specific use cases including shallow direct bury deployments, traditional piers, and problematic wet vault installs. With its small size, robust waterproof case and connector, +/-1.5° tilt range, dual-purpose cable, and accessories for both posthole and vault installation, Trillium Horizon is optimized for usability as well as performance.

  8. Arthropods in Decomposing Wood of the Atchafalaya River Basin

    Treesearch

    B.G. Lockaby; B.D. Keeland; John A. Stanturf; M.D. Rice; G. Hodges; R.M. Governo

    2002-01-01

    Changes in arthropod populations (numbers of individuals identified to the family level in most cases) were studied during the decomposition of coarse woody debris (CWD) in the Atchafalaya River Basin of Louisiana. The arthropod study was linked with a CWD decomposition study installed after disturbance by Hurricane Andrew. Arthropod numbers were compared between two...

  9. Evaluation of experimental installation of fly ash concrete in Louisa : Concrete case study number 32.

    DOT National Transportation Integrated Search

    1979-01-01

    The objective of this study was to investigate the resistance of field concretes containing fly ash to damage from cycles of freezing and thawing as evidenced by scaling, based upon a reevaluation of a field project. In 1955 and 1956 an experimental ...

  10. Land-use efficiency of big solar.

    PubMed

    Hernandez, Rebecca R; Hoffacker, Madison K; Field, Christopher B

    2014-01-21

    As utility-scale solar energy (USSE) systems increase in size and numbers globally, there is a growing interest in understanding environmental interactions between solar energy development and land-use decisions. Maximizing the efficient use of land for USSE is one of the major challenges in realizing the full potential of solar energy; however, the land-use efficiency (LUE; Wm(-2)) of USSE remains ambiguous. We quantified the capacity-based LUE of 183 USSE installations (>20 MW; planned, under construction, and operating) using California as a case study. In California, USSE installations are concentrated in the Central Valley and interior regions of southern California and have a LUE of 35.0 Wm(-2). The installations occupy approximately 86,000 ha and more land is allocated for photovoltaic schemes (72 294 ha) than for concentrating solar power (13,604 ha). Photovoltaic installations are greater in abundance (93%) than concentrating solar power, but technology type and nameplate capacity has no impact on capacity-based LUE. More USSE installations are on private land (80%) and have a significantly greater LUE (35.8 Wm(-2)) than installations on public land (25.4 Wm(-2)). Our findings can be used to better understand and improve the LUE of USSE, thereby maximizing economic, energetic, and environmental returns on investments.

  11. Using a Combined Platform of Swarm Intelligence Algorithms and GIS to Provide Land Suitability Maps for Locating Cardiac Rehabilitation Defibrillators

    PubMed Central

    KAFFASH-CHARANDABI, Neda; SADEGHI-NIARAKI, Abolghasem; PARK, Dong-Kyun

    2015-01-01

    Background: Cardiac arrest is a condition in which the heart is completely stopped and is not pumping any blood. Although most cardiac arrest cases are reported from homes or hospitals, about 20% occur in public areas. Therefore, these areas need to be investigated in terms of cardiac arrest incidence so that places of high incidence can be identified and cardiac rehabilitation defibrillators installed there. Methods: In order to investigate a study area in Petersburg, Pennsylvania State, and to determine appropriate places for installing defibrillators with 5-year period data, swarm intelligence algorithms were used. Moreover, the location of the defibrillators was determined based on the following five evaluation criteria: land use, altitude of the area, economic conditions, distance from hospitals and approximate areas of reported cases of cardiac arrest for public places that were created in geospatial information system (GIS). Results: The A-P HADEL algorithm results were more precise about 27.36%. The validation results indicated a wider coverage of real values and the verification results confirmed the faster and more exact optimization of the cost function in the PSO method. Conclusion: The study findings emphasize the necessity of applying optimal optimization methods along with GIS and precise selection of criteria in the selection of optimal locations for installing medical facilities because the selected algorithm and criteria dramatically affect the final responses. Meanwhile, providing land suitability maps for installing facilities across hot and risky spots has the potential to save many lives. PMID:26587471

  12. U. K. pressing campaign to improve offshore safety

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knott, D.

    1994-02-14

    The U.K. government is making progress in its campaign to improve the safety of personnel working offshore. The government's Health and Safety Executive (HSE) plans to assess and pass judgment on at lease one safety plan, called a safety case, from each U.K. North Sea operator as soon as possible. HSE has agreed with the industry on a list of 61 priority safety cases, known as exemplars. Feedback from exemplar assessment will help operators review safety management and assist in preparation or revision of future safety cases. It also will give HSE practice in assessing a range of case types.more » The requirement for a safety program is part of new U.K. offshore legislation designed to prevent another accident similar to the Piper Alpha platform fire and explosion of 1988. After the transition period it will be against the law to operate an oil and gas installation in British waters without an accepted safety case. Besides existing installations, safety cases are also required for new installations reaching design stage by May 31, 1993, the date safety case regulations went into force. The paper describes the Cullen report, companies' experiences with the new law, and the safety assessment progress so far.« less

  13. Outsourcing a High Speed Internet Access Project: An Information Technology Class Case Study in Three Parts

    ERIC Educational Resources Information Center

    Platt, Richard G.; Carper, William B.; McCool, Michael

    2010-01-01

    In early 2004, the Hilton Hotels Corporation (HHC) required that all of its hotels (both owned and franchised) install high-speed Internet access (HSIA) in all of their rooms by June 2004. This case focuses on how one of its franchise properties located on the northern gulf coast of Florida (the Hilton Sandestin Beach Golf Resort &…

  14. Methods for protecting subsea pipelines and installations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rochelle, W.R.; Simpson, D.M.

    1981-01-01

    The hazards for subsea pipelines and installations are described. Methods currently being used to protect subsea pipelines and installations are discussed with the emphasis on various trenching methods and equipment. Technical data on progress rates for trenching and feasible depths of trench are given. Possible methods for protection against icebergs are discussed. A case for more comprehensive data on icebergs is presented. Should a pipeline become damaged, repair methods are noted.

  15. Energy Storage Systems: A Manufacturer’s Perspective

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gallant, Eric

    From a manufacturer’s perspective, Eric Gallant of GS Battery presents a case study of energy storage installations, emphasizing energy storage in terms of its impact on people’s lives, as well as changes in such related areas as evolving codes and standards.

  16. Retrospective chart analysis on survival rate of fixtures installed at the tuberosity bone for cases with missing unilateral upper molars: a study of 7 cases.

    PubMed

    Park, Young-Jin; Cho, Sung-Am

    2010-06-01

    To evaluate the survival rate of implants placed in the maxillary tuberosity region using the fixed prosthesis in partially edentulous cases. Of implant-treated patients who visited Kyung Pook National University Hospital, 7 partially edentulous patients (2 male and 5 female; mean age, 52.3 years; range, approximately 43 to 65) were selected according to the following criteria: 1) less than 3-mm thickness alveolar bone reaming at the first molar area and 2) 1 to 2 fixture premolars, with the additional implant at the maxillary tuberosity region. For the control group, patients who had nontuberosity areas were selected. After 1 to 7 years, marginal bone level, fixture mobility, and radiolucency of tuberosity fixtures of the fixed prostheses were evaluated by digital panorama (Starpacs, Infinitt, Seoul, Korea). None of the fixtures of the tuberosity-installed implants for 1 to 7 years failed. The marginal bone level around the implants of the maxillary tuberosity 1 to 6 years (average 3.4 years) after the final prostheses was approximately 0.6 to 1.3 mm, with an average of 0.94 mm. The fixture installation at the maxillary tuberosity using the unilateral partially edentulous implant-fixed prosthesis would be a clinically acceptable treatment module. 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  17. The Land-Use Efficiency of Big Solar

    NASA Astrophysics Data System (ADS)

    Hernandez, R. R.; Hoffacker, M.; Field, C. B.

    2013-12-01

    As utility-scale solar energy (USSE) systems increase in size and numbers globally, there is a growing interest in understanding environmental interactions between solar energy development and land-use decisions. Maximizing the efficient use of land for USSE is one of the major challenges in realizing the full potential of solar energy, however, the land-use efficiency (LUE; Wm-2) of USSE remains unknown. We quantified the nominal LUE of 183 USSE installations (> 20 megawatts; planned, under construction, and operating) using California as a case study. In California, we found that USSE installations are concentrated in the Central Valley and desert interior of southern California and have a LUE of 35.01 Wm-2. The installations comprise approximately 86,000 hectares (ha) and more land is allocated for photovoltaic schemes (72,294 ha) than for concentrating solar power (13,604 ha). Photovoltaic installations are greater in abundance (93%) than concentrating solar power, but technology type and nameplate capacity has no impact on LUE. More USSE installations are on private land (80%) and have a significantly greater LUE (35.83 Wm-2) than installations on public land (25.42 Wm-2). We show how LUE can be improved and how co-benefit opportunities can be integrated with USSE enterprises to maximize their economic, energetic, and environmental returns on investment. (Left) The distribution of utility-scale solar energy installations in California (constructed and in progress) by technology type: concentrating solar power and photovoltaic with county lines shown. (Right) The distribution of utility-scale solar energy installations in California (constructed and in progress) by location: public or privately owned land. Larger capacity installations (megawatts) have relatively greater point size.

  18. Leukemia-related mortality in towns lying in the vicinity of metal production and processing installations.

    PubMed

    García-Pérez, Javier; López-Cima, María Felicitas; Boldo, Elena; Fernández-Navarro, Pablo; Aragonés, Nuria; Pollán, Marina; Pérez-Gómez, Beatriz; López-Abente, Gonzalo

    2010-10-01

    Releases to the environment of toxic substances stemming from industrial metal production and processing installations can pose a health problem to populations in their vicinity. To investigate whether there might be excess leukemia-related mortality in populations residing in towns in the vicinity of Spanish metal industries included in the European Pollutant Emission Register. Ecologic study designed to examine mortality due to leukemia at a municipal level, during the period 1994-2003. Population exposure to pollution was estimated on the basis of distance from town of residence to pollution source. Using Poisson regression models, we analyzed: risk of dying from leukemia in a 5-kilometer zone around installations which had become operational prior to 1990; effect of pollution discharge route and type of industrial activity; and risk gradient within a 50-kilometer radius of such installations. Excess mortality (relative risk, 95% confidence interval) was detected in the vicinity of pre-1990 installations (1.07, 1.02-1.13 in men; 1.05, 1.00-1.11 in women), with this being more elevated in the case of installations that released pollution to air versus water. On stratifying by type of industrial activity, statistically significant associations were also observed among women residing in the vicinity of galvanizing installations (1.58, 1.09-2.29) and surface-treatment installations using an electrolytic or chemical process (1.34, 1.10-1.62), which released pollution to air. There was an effect whereby risk increased with proximity to certain installations. The results suggest an association between risk of dying due to leukemia and proximity to Spanish metal industries. Copyright 2010 Elsevier Ltd. All rights reserved.

  19. A 12-year National Study of Suicide by Jumping From Bridges in Norway.

    PubMed

    Sæheim, Aleksandra; Hestetun, Ingebjørg; Mork, Erlend; Nrugham, Latha; Mehlum, Lars

    2017-01-01

    Studies from several countries suggest that erecting fences on bridges more commonly used for suicide by jumping may be an effective way of reducing the risk of suicide by jumping from these bridges. Distribution of suicides by jumping off bridges has not yet been studied on a national level in any country. This study included all suicides by jumping from high places registered in the Norwegian Cause of Death Registry (COD) in the period 1999-2010 (n = 319). Combining data from the COD registry and information from police records, 71 cases of suicide by jumping off a bridge were identified involving 36 bridges. This form of suicide constituted approximately 1% of all suicides in Norway in the period 1999-2010. Almost half of these suicides were registered at only 6 bridges. Three Norwegian bridges were secured during the observation period of this study. Two bridges had barriers installed on the full length of the bridge with 11 suicides registered before barriers were installed, and none after. On the 1 bridge that was only partially secured, no change in numbers of suicides was observed after barriers were installed. One-third of jumps from bridges occurred over land. We found that although suicide by jumping off bridges was a relatively rare event, there is a potential for saving lives by installing physical barriers on bridges that are more commonly used for suicide by jumping.

  20. Development of a Semi-submersible Barge for the installation of a TLP floating substructure. TLPWIND® case study

    NASA Astrophysics Data System (ADS)

    Amate, Juan; Sánchez, Gustavo D.; González, Gonzalo

    2016-09-01

    One of the biggest challenges to introduce Tension Leg Platform (TLP) technology into the Offshore Wind market are the Transport & Installation (T&I) stages, since most of TLPs are not self-stable as semisubmersible or SPAR platforms, and consequently requires additional means to perform these operations. This paper addresses this problem that has been overcome through the development of a Semi-submersible “Transport & Installation” Barge (SSB) for Iberdrola's TLPWIND® floating support structure. The Semi-submersible Barge has been designed both through the use of numerical models and an extensive basin testing campaign carried out at the University of Strathclyde facilities. This paper also includes an estimation of the duration in time to carry out the installation process of a Floating Offshore Wind Farm, comprising 100x5MW TLPWIND® units in different scenarios.

  1. Car Safety Seat Usage and Selection Among Families Attending University Hospital Limerick.

    PubMed

    Scully, P; Finner, N; Letshwiti, J B; O'Gorman, C

    2016-05-10

    The safest way for children to travel within a car is by provision of a weight-appropriate safety-seat. To investigate this, we conducted a cross-sectional study of adult parents who had children under 12 years, and collected information related to: car use, safety-seat legislation, and type of safety-seat employed. Data were reviewed on 120 children from 60 respondents. Ninety-eight (81.7%) children were transported daily by car. Forty-eight (81.4%) respondents were aware that current safety-seat legislation is based on the weight of the child. One hundred and seven (89.9%) children were restrained during travel using a car safety-seat. One hundred and two (96.2%) safety seats were newly purchased, installed in 82.3% (88) cases by family members with installation instructions fully read in 58 (55.2%) cases. Ninety-nine (83.2%) children were restrained using an appropriate safety-seat for their weight. The results show that four out of five families are employing the most appropriate safety-seat for their child, so providing an effective mechanism to reduce car-related injury. However, the majority of safety-seats are installed by family members, which may have child safety consequences.

  2. Novel Use of Flu Surveillance Data: Evaluating Potential of Sentinel Populations for Early Detection of Influenza Outbreaks.

    PubMed

    Daughton, Ashlynn R; Velappan, Nileena; Abeyta, Esteban; Priedhorsky, Reid; Deshpande, Alina

    2016-01-01

    Influenza causes significant morbidity and mortality each year, with 2-8% of weekly outpatient visits around the United States for influenza-like-illness (ILI) during the peak of the season. Effective use of existing flu surveillance data allows officials to understand and predict current flu outbreaks and can contribute to reductions in influenza morbidity and mortality. Previous work used the 2009-2010 influenza season to investigate the possibility of using existing military and civilian surveillance systems to improve early detection of flu outbreaks. Results suggested that civilian surveillance could help predict outbreak trajectory in local military installations. To further test that hypothesis, we compare pairs of civilian and military outbreaks in seven locations between 2000 and 2013. We find no predictive relationship between outbreak peaks or time series of paired outbreaks. This larger study does not find evidence to support the hypothesis that civilian data can be used as sentinel surveillance for military installations. We additionally investigate the effect of modifying the ILI case definition between the standard Department of Defense definition, a more specific definition proposed in literature, and confirmed Influenza A. We find that case definition heavily impacts results. This study thus highlights the importance of careful selection of case definition, and appropriate consideration of case definition in the interpretation of results.

  3. Baxter Community—High Performance Green Building

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2009-02-16

    This case study describes the Baxter community built by David Weekley Homes, which is reducing their energy demand through a number of techniques including advanced air sealing techniques, the installation of SEER 14 air conditioners, and Low-e windows in conjunction with conventional framing and insulation.

  4. Energy System Basics and Distribution Integration Video Series | Energy

    Science.gov Websites

    renewablesparticularly solar photovoltaic (PV) technologiesonto the distribution grid. Solar Energy Technologies PV Integration Case Studies Integrating Photovoltaic Systems onto Secondary Network Distribution Systems Standards and Codes for U.S. Photovoltaic System Installation Network-Optimal Control of Photovoltaics on

  5. Technology Solutions Case Study: Guidance on Taped Insulating Sheathing Drainage Planes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    The energy efficiency-based financial benefits of adding exterior insulation are well accepted by the building industry, and using exterior insulation as the drainage plane is the next logical step. This case study focuses on the field implementation of taped board insulation as the drainage plane in both new and retrofit residential applications, and provides information and recommendations for insulation contractors, general contractors, builders, remodelers, mechanical contractors, and homeowners. The order of work completed during home construction and retrofit improvements is important. Health and safety issues must be addressed first and are more important than durability issues, and durability issues aremore » more important than saving energy. Three significant items are required to make taped insulating sheathing a simple, long term, and durable drainage plane: first, horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists, use superior materials; and, frequent installation inspection and regular trade training are required to maintain proper installation.« less

  6. Building America Case Study: Duct in Conditioned Space in a Dropped Ceiling or Fur-down, Gainesville, Florida (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2014-09-01

    Forced air distribution systems (duct systems) typically are installed out of sight for aesthetic reasons, most often in unconditioned areas such as an attic or crawlspace. Any leakage of air to or from the duct system (duct leakage) in unconditioned space not only loses energy, but impacts home and equipment durability and indoor air quality. An obvious solution to this problem is to bring the duct system into the interior of the house, either by sealing the area where the ducts are installed (sealed attic or crawlspace) or by building an interior cavity or chase above the ceiling plane (raisedmore » ceiling or fur-up chase) or below the ceiling plane (dropped ceiling or fur-down) for the duct system. This case study examines one Building America builder partner's implementation of an inexpensive, quick and effective method of building a fur-down or dropped ceiling chase.« less

  7. A case study in innovative outreach--combining training, research, and technology transfer to address real-world problems.

    PubMed Central

    Chang, D P

    1998-01-01

    Outreach, training, technology transfer, and research are often treated as programmatically distinct activities. The interdisciplinary and applied aspects of the Superfund Basic Research Program offer an opportunity to explore different models. A case study is presented that describes a collaborative outreach effort that combines all of the above. It involves the University of California's Davis and Berkeley program projects, the University of California Systemwide Toxic Substances Research and Teaching Program, the U.S. Navy's civilian workforce at the former Mare Island Naval Shipyard, Vallejo, California (MINSY), a Department of Defense (DoD) Environmental Education Demonstration Grant program, and the Private Industry Council of Napa and Sonoma counties in California. The effort applied a Superfund-developed technology to a combined waste, radium and polychlorinated biphenyl contamination, stemming from a problematic removal action at an installation/restoration site at MINSY. The effort demonstrates that opportunities for similar collaborations are possible at DoD installations. PMID:9703494

  8. Modeling zero-modified count and semicontinuous data in health services research part 2: case studies.

    PubMed

    Neelon, Brian; O'Malley, A James; Smith, Valerie A

    2016-11-30

    This article is the second installment of a two-part tutorial on the analysis of zero-modified count and semicontinuous data. Part 1, which appears as a companion piece in this issue of Statistics in Medicine, provides a general background and overview of the topic, with particular emphasis on applications to health services research. Here, we present three case studies highlighting various approaches for the analysis of zero-modified data. The first case study describes methods for analyzing zero-inflated longitudinal count data. Case study 2 considers the use of hurdle models for the analysis of spatiotemporal count data. The third case study discusses an application of marginalized two-part models to the analysis of semicontinuous health expenditure data. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  9. Effects of counter torque and transposition (transfer) of installed implants timing on their integration in dog tibia

    PubMed Central

    Fathi, Shima; Ghanavati, Farzin

    2015-01-01

    PURPOSE The purpose of this research was to evaluate the amount of reosseointegration after counter torquing (reverse torque) and transposing the installed implants at different times. MATERIALS AND METHODS This study was done on ten tibiae of five cross-bred dogs. At the first day one implant was installed in each tibia. After one week half of the implants were randomly counter torqued (1WCT) and the other half were explanted and reimplanted in a new juxtaposition site (transposed)(1WT). At the same time three new implants were installed in each dog, one of them was considered as one week control (1WC) and remaining two as 8 week groups (8WCT&8WT). After eight weeks the 1WCT and 1WT implants were loosened by counter torque and the quantity of needed force for liberation was measured with the digital device (BGI). At the same time one implant was installed in each dog as eight week control (8WC) and the same protocol was repeated for 8 week groups after another 8 weeks. RESULTS All implants were osseointegrated. Mean quantities of osseointegration in case groups indicated better amounts rather than control groups. CONCLUSION Counter torque or transposition of the installed implants one week or eight weeks after the implantation did lead to osseointegration. PMID:25722840

  10. Case Study: Installation and Monitoring of Green Infrastructure Stormwater Controls in Louisville, Kentucky

    EPA Science Inventory

    In 2005, the Louisville and Jefferson County Metropolitan Sewer District (MSD) entered into a Consent Decree with the U.S. Environmental Protection Agency (EPA), Kentucky Department for Environmental Protection, and the U.S. Department of Justice. In 2009, MSD submitted the Inte...

  11. Multi-Protocol LAN Design and Implementation: A Case Study.

    ERIC Educational Resources Information Center

    Hazari, Sunil

    1995-01-01

    Reports on the installation of a local area network (LAN) at East Carolina University. Topics include designing the network; computer labs and electronic mail; Internet connectivity; LAN expenses; and recommendations on planning, equipment, administration, and training. A glossary of networking terms is also provided. (AEF)

  12. A case study : Michigan Intelligent Transportation System Center : use of a design/build/warranty contract

    DOT National Transportation Integrated Search

    2000-03-01

    Many ITS projects are stand-alone in nature, and do not have to be procured under rules for construction. The installation of field devices and communications infrastructure often meets the definition of construction. However, if a project involves t...

  13. Justification of indirect methods of bending stresses polyethylene pipes evaluation

    NASA Astrophysics Data System (ADS)

    Serebrennikov, A. A.; Serebrennikov, D. A.; Hakimov, Z. R.

    2017-10-01

    The world and Russian companies have a long experience of the polyethylene pipeline installation and operation. At the same time, the significant attention is paid to the improvement of the relevant machines and the production technology. The polyethylene pipeline installation experience proves that its operation properties (reliability and durability) depend on physical and mechanical characteristics of polyethylene, which should be saved during its installation. Defects can occur, including in cases when the pipe is subjected to the significant bending stresses during installation. To evaluate these stresses, including when exposed to cold weather conditions, an indirect method based on the relationship between strength characteristics and occurred deformations is proposed.

  14. 47 CFR 80.913 - Radiotelephone receivers.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... pursuant to § 80.909 of this part. (c) If a very high frequency radiotelephone installation is provided... radiotelephone installation must have a sensitivity of at least 50 microvolts in the case of MF equipment, and 1... be capable of efficient operation when energized by the reserve source of energy. (g) The sensitivity...

  15. 47 CFR 80.913 - Radiotelephone receivers.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... pursuant to § 80.909 of this part. (c) If a very high frequency radiotelephone installation is provided... radiotelephone installation must have a sensitivity of at least 50 microvolts in the case of MF equipment, and 1... be capable of efficient operation when energized by the reserve source of energy. (g) The sensitivity...

  16. 47 CFR 80.913 - Radiotelephone receivers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... pursuant to § 80.909 of this part. (c) If a very high frequency radiotelephone installation is provided... radiotelephone installation must have a sensitivity of at least 50 microvolts in the case of MF equipment, and 1... be capable of efficient operation when energized by the reserve source of energy. (g) The sensitivity...

  17. 47 CFR 80.913 - Radiotelephone receivers.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... pursuant to § 80.909 of this part. (c) If a very high frequency radiotelephone installation is provided... radiotelephone installation must have a sensitivity of at least 50 microvolts in the case of MF equipment, and 1... be capable of efficient operation when energized by the reserve source of energy. (g) The sensitivity...

  18. 47 CFR 80.913 - Radiotelephone receivers.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... pursuant to § 80.909 of this part. (c) If a very high frequency radiotelephone installation is provided... radiotelephone installation must have a sensitivity of at least 50 microvolts in the case of MF equipment, and 1... be capable of efficient operation when energized by the reserve source of energy. (g) The sensitivity...

  19. 40 CFR 75.66 - Petitions to the Administrator.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... for each submission. (b) Alternative flow monitoring method petition. In cases where no location exists for installation of a flow monitor in either the stack or the ducts serving an affected unit that satisfies the minimum physical siting criteria in appendix A of this part or where installation of a flow...

  20. 40 CFR 75.66 - Petitions to the Administrator.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... for each submission. (b) Alternative flow monitoring method petition. In cases where no location exists for installation of a flow monitor in either the stack or the ducts serving an affected unit that satisfies the minimum physical siting criteria in appendix A of this part or where installation of a flow...

  1. 40 CFR 75.66 - Petitions to the Administrator.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... for each submission. (b) Alternative flow monitoring method petition. In cases where no location exists for installation of a flow monitor in either the stack or the ducts serving an affected unit that satisfies the minimum physical siting criteria in appendix A of this part or where installation of a flow...

  2. 40 CFR 75.66 - Petitions to the Administrator.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... for each submission. (b) Alternative flow monitoring method petition. In cases where no location exists for installation of a flow monitor in either the stack or the ducts serving an affected unit that satisfies the minimum physical siting criteria in appendix A of this part or where installation of a flow...

  3. A New Standard Installation Method of the Offline Seismic Observation Station in Heavy Snowfall Area of Tohoku Region

    NASA Astrophysics Data System (ADS)

    Hirahara, S.; Nakayama, T.; Hori, S.; Sato, T.; Chiba, Y.; Okada, T.; Matsuzawa, T.

    2015-12-01

    Soon after the 2011 Tohoku earthquake, seismic activity of Tohoku region, NE Japan is induced in the inland area of Akita prefecture and the border area between Fukushima and Yamagata prefectures. We plan to install a total of 80 offline seismic observation stations in these areas for studying the effect of megathrust earthquake on the activities of inland earthquakes. In our project, maintenance will be held twice-a-year for 4 years from 2015 by using 2.0Hz short-period 3-component seismometer, KVS-300 and ultra-low-power data logger, EDR-X7000 (DC12V 0.08W power supply). We installed seismometer on the rock surface or the slope of the natural ground at the possible sites confirmed with low noise level to obtain distinct seismic waveform data. We report an improvement in installation method of the offline seismic observation station in the heavy snowfall area of Tohoku region based on the retrieved data. In the conventional method, seismometer was installed in the hand-dug hole of a slope in case it is not waterproof. Data logger and battery were installed in the box container on the ground surface, and then, GPS antenna was installed on the pole fixed by stepladder. There are risks of the inclination of seismometer and the damage of equipment in heavy snowfall area. In the new method, seismometer is installed in the robust concrete box on the buried basement consists of precast concrete mass to keep its horizontality. Data logger, battery, and GPS antenna are installed on a high place by using a single pole with anchor bolt and a pole mount cabinet to enhance their safety. As a result, total costs of installation are kept down because most of the equipment is reusable. Furthermore, an environmental burden of waste products is reduced.

  4. Statistical Analysis of CFD Solutions from the Third AIAA Drag Prediction Workshop

    NASA Technical Reports Server (NTRS)

    Morrison, Joseph H.; Hemsch, Michael J.

    2007-01-01

    The first AIAA Drag Prediction Workshop, held in June 2001, evaluated the results from an extensive N-version test of a collection of Reynolds-Averaged Navier-Stokes CFD codes. The code-to-code scatter was more than an order of magnitude larger than desired for design and experimental validation of cruise conditions for a subsonic transport configuration. The second AIAA Drag Prediction Workshop, held in June 2003, emphasized the determination of installed pylon-nacelle drag increments and grid refinement studies. The code-to-code scatter was significantly reduced compared to the first DPW, but still larger than desired. However, grid refinement studies showed no significant improvement in code-to-code scatter with increasing grid refinement. The third Drag Prediction Workshop focused on the determination of installed side-of-body fairing drag increments and grid refinement studies for clean attached flow on wing alone configurations and for separated flow on the DLR-F6 subsonic transport model. This work evaluated the effect of grid refinement on the code-to-code scatter for the clean attached flow test cases and the separated flow test cases.

  5. Safety distance assessment of industrial toxic releases based on frequency and consequence: a case study in Shanghai, China.

    PubMed

    Yu, Q; Zhang, Y; Wang, X; Ma, W C; Chen, L M

    2009-09-15

    A case study on the safety distance assessment of a chemical industry park in Shanghai, China, is presented in this paper. Toxic releases were taken into consideration. A safety criterion based on frequency and consequence of major hazard accidents was set up for consequence analysis. The exposure limits for the accidents with the frequency of more than 10(-4), 10(-5)-10(-4) and 10(-6)-10(-5) per year were mortalities of 1% (or SLOT), 50% (SLOD) and 75% (twice of SLOD) respectively. Accidents with the frequency of less than 10(-6) per year were considered incredible and ignored in the consequence analysis. Taking the safety distance of all the hazard installations in a chemical plant into consideration, the results based on the new criterion were almost smaller than those based on LC50 or SLOD. The combination of the consequence and risk based results indicated that the hazard installations in two of the chemical plants may be dangerous to the protection targets and measurements had to be taken to reduce the risk. The case study showed that taking account of the frequency of occurrence in the consequence analysis would give more feasible safety distances for major hazard accidents and the results were more comparable to those calculated by risk assessment.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Im, Piljae; Liu, Xiaobing

    High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This paper highlights the findings of a case study of one of the ARRA-funded GSHP demonstration projects, a ground-source variable refrigerant flow (GS-VRF) system installed at the Human Health Building at Oakland University in Rochester, Michigan.more » This case study is based on the analysis of measured performance data, maintenance records, construction costs, and simulations of the energy consumption of conventional central heating, ventilation, and air-conditioning (HVAC) systems providing the same level of space conditioning as the demonstrated GS-VRF system. The evaluated performance metrics include the energy efficiency of the heat pump equipment and the overall GS-VRF system, pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of the GS-VRF system compared with conventional HVAC systems. This case study also identified opportunities for reducing uncertainties in the performance evaluation, improving the operational efficiency, and reducing the installed cost of similar GSHP systems in the future.« less

  7. Can Learning Motivation Predict Learning Achievement? A Case Study of a Mobile Game-Based English Learning Approach

    ERIC Educational Resources Information Center

    Tsai, Chia-Hui; Cheng, Ching-Hsue; Yeh, Duen-Yian; Lin, Shih-Yun

    2017-01-01

    This study applied a quasi-experimental design to investigate the influence and predictive power of learner motivation for achievement, employing a mobile game-based English learning approach. A system called the Happy English Learning System, integrating learning material into a game-based context, was constructed and installed on mobile devices…

  8. Optimization of turbine positioning in water distribution networks. A Sicilian case study

    NASA Astrophysics Data System (ADS)

    Milici, Barbara; Messineo, Simona; Messineo, Antonio

    2017-11-01

    The potential energy of water in Water Distribution Networks (WDNs), is usually dissipated by Pressure Reduction Valves (PRVs), thanks to which water utilities manage the pressure level in selected nodes of the network. The present study explores the use of economic hydraulic machines, pumps as turbines (PATs), to produce energy in a small network with the aim to avoid dissipation in favour of renewable energy production. The proposed study is applied to a WDN located in a town close to Palermo (Sicily), where users often install private tanks, to collect water during the period of water scarcity conditions. As expected, the economic benefit of PATs installation in WDNs is affected by the presence of private tanks, whose presence deeply modifies the network from designed condition. The analysis is carried out by means of a mathematical model, which is able to simulate dynamically water distribution networks with private tanks and PATs. As expected, the advantage of PATs' installation in terms of renewable energy recovery is strictly conditioned by their placement in the WDN.

  9. Rapid Assessment of Remedial Effectiveness and Rebound in Fractured Bedrock

    DTIC Science & Technology

    2017-10-01

    Permanent 5-inch diameter steel casing was then installed to a depth of 58.3 ft-bgs, and pressure-grouted in place using cement /bentonite grout. Once the...collected from 64 feet to 78 feet bgs. A 2-inch stainless steel well, screened from 64 to 74 feet bgs, was installed within the borehole. A filter pack was...installed from 63.5 ft to 74.5 ft bgs, and the remainder of the borehole was sealed with a bentonite seal and cement /bentonite grout. Therefore

  10. The installation and correction of compasses in airplanes

    NASA Technical Reports Server (NTRS)

    Schoeffel, M F

    1927-01-01

    The saving of time that results from flying across country on compass headings is beginning to be widely recognized. At the same time the general use of steel tube fuselages has made a knowledge of compass correction much more necessary than was the case when wooden fuselages were the rule. This paper has been prepared primarily for the benefit of the pilot who has never studied navigation and who does not desire to go into the subject more deeply than to be able to fly compass courses with confidence. It also contains material for the designer who wishes to install his compasses with the expectation that they may be accurately corrected.

  11. RADON MITIGATION IN SCHOOLS: CASE STUDIES OF RADON MITIGATION SYSTEMS INSTALLED BY EPA IN FOUR MARYLAND SCHOOLS ARE PRESENTED

    EPA Science Inventory

    The first part of this two-part paper discusses radon entry into schools, radon mitigation approaches for schools, and school characteristics (e.g., heating, ventilation, and air-conditioning -- HVAC-- system design and operation) that influence radon entry and mitigation system ...

  12. Case Study: Installation and Monitoring of Green Infrastructure Stormwater Controls in Louisville, Kentucky (Abstract)

    EPA Science Inventory

    In 2005, the Louisville and Jefferson County Metropolitan Sewer District (MSD) entered into a Consent Decree with the U.S. Environmental Protection Agency (EPA), Kentucky Dept. of Environmental Protection, and the U.S. Department of Justice. In 2009, the MSD submitted the Integr...

  13. Case Study: Installation and Monitoring of Green Infrastructure Stormwater Controls in Louisville, Kentucky - slides

    EPA Science Inventory

    In 2005, the Louisville and Jefferson County Metropolitan Sewer District (MSD) entered into a Consent Decree with the U.S. Environmental Protection Agency (EPA), Kentucky Department for Environmental Protection, and the U.S. Department of Justice. MSD committed to monitor the pe...

  14. Technical Approach for In Situ Biological Treatment Research: Bench- Scale Experiments

    DTIC Science & Technology

    1993-08-01

    1 CONVERSION FACTORS, NON-SI TO SI (METRIC) UNITS OF MEASUREMENT . . 5 PART I: INTRODUCTION...141 REFERENCES ....................... .............................. 142 TABLES 1 -4 APPENDIX A: IN SITU IMPLEMENTATION CASE STUDIES...TREATMENT RESEARCH: BENCH-SCALE EXPERIMENTS PART I: INTRODUCTION Background 1 . Many US Army installations have areas of contamination requiring

  15. USDA and Florida Power & Light Company Successfully Save $85K/year with UESC Collaboration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Case study features the U.S. Department of Agriculture's (USDA) Miami Subtropical Horticulture Research Station, which was in need of several energy upgrades. USDA teamed up with Florida Light & Power to install much needed facility improvements are creating a savings of $85,000 per year.

  16. Environmental Mitigation in Transportation Planning : Case Studies in Meeting SAFETEA-LU Section 6001 Requirements for the FHWA, Office of Planning Environment and Realty

    DOT National Transportation Integrated Search

    1996-12-01

    THIS PROJECT IDENTIFIED TRAFFIC PARAMETERS AND THEIR REQUIRED ACCURACIES FOR CHARACTERIZING TRAFFIC FLOW IN CONVENTIONAL AND NEWER INTELLIGENT TRANSPORTATION SYSTEMS (ITS), OBTAINED STATE-OF-THE-ART DETECTORS AND INSTALLED AND EVALUATED THEM IN THREE...

  17. Geothermal Heat Pumps Score High Marks in Schools.

    ERIC Educational Resources Information Center

    National Renewable Energy Lab (DOE).

    Geothermal heat pumps (GHPs) are showing their value in providing lower operating and maintenance costs, energy efficiency, and superior classroom comfort. This document describes what GHPs are and the benefits a school can garner after installing a GHP system. Three case studies are provided that illustrate these benefits. Finally, the Department…

  18. Are Australian consumers willing to pay for the installation of reversing cameras in motor vehicles?

    PubMed

    Jones, Sandra C; Telenta, Joanne

    2010-04-01

    In Australia, more than one toddler per month dies from being run over in a driveway and many more are injured. While there is currently no regulation in Australia regarding reverse warning systems, the issue has been debated over the years following several high profile cases. A computer-assisted telephone interview (CATI) survey of NSW households was undertaken in March 2008. Respondents were asked about their willingness to pay for the installation of vehicle reversing cameras at the expense of the purchaser. The survey was completed by 590 respondents. There were no significant differences between males and females for willingness to pay $500 or $300 for a reversing camera in their current vehicle; however females were more willing to pay $150. There were no significant differences between age groups in willingness to pay for the installation. More than two-thirds of respondents would support legislation if it increased the cost of new cars by $300 and more than half if it increased by $500. This study suggests that the majority of adults would be prepared to pay a small amount of money to install a reversing camera in their current vehicle, but not sufficient to cover the full cost of installation.

  19. 30 CFR 250.518 - What are the requirements for casing pressure management?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...? Once you install your wellhead, you must meet the casing pressure management requirements of API RP 90... there is a conflict between API RP 90 and the casing pressure requirements of this subpart, you must...

  20. Electromagnetically levitated vibration isolation system for the manufacturing process of silicon monocrystals

    NASA Technical Reports Server (NTRS)

    Kanemitsu, Yoichi; Watanabe, Katsuhide; Yano, Kenichi; Mizuno, Takayuki

    1994-01-01

    This paper introduces a study on an Electromagnetically Levitated Vibration Isolation System (ELVIS) for isolation control of large-scale vibration. This system features no mechanical contact between the isolation table and the installation floor, using a total of four electromagnetic actuators which generate magnetic levitation force in the vertical and horizontal directions. The configuration of the magnet for the vertical direction is designed to prevent any generation of restoring vibratory force in the horizontal direction. The isolation system is set so that vibration control effects due to small earthquakes can be regulated to below 5(gal) versus horizontal vibration levels of the installation floor of up t 25(gal), and those in the horizontal relative displacement of up to 30 (mm) between the floor and levitated isolation table. In particular, studies on the relative displacement between the installation floor and the levitated isolation table have been made for vibration control in the horizontal direction. In case of small-scale earthquakes (Taft wave scaled: max. 25 gal), the present system has been confirmed to achieve a vibration isolation to a level below 5 gal. The vibration transmission ratio of below 1/10 has been achieved versus continuous micro-vibration (approx. one gal) in the horizontal direction on the installation floor.

  1. 40 CFR 265.301 - Design and operating requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... landfill unit must install two or more liners and a leachate collection and removal system above and between such liners, and operate the leachate collection and removal system, in accordance with § 264.301... case of any unit in which the liner and leachate collection system has been installed pursuant to the...

  2. 40 CFR 265.301 - Design and operating requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... landfill unit must install two or more liners and a leachate collection and removal system above and between such liners, and operate the leachate collection and removal system, in accordance with § 264.301... case of any unit in which the liner and leachate collection system has been installed pursuant to the...

  3. 40 CFR 265.301 - Design and operating requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... landfill unit must install two or more liners and a leachate collection and removal system above and between such liners, and operate the leachate collection and removal system, in accordance with § 264.301... case of any unit in which the liner and leachate collection system has been installed pursuant to the...

  4. 40 CFR 265.301 - Design and operating requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... landfill unit must install two or more liners and a leachate collection and removal system above and between such liners, and operate the leachate collection and removal system, in accordance with § 264.301... case of any unit in which the liner and leachate collection system has been installed pursuant to the...

  5. 40 CFR 265.301 - Design and operating requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... landfill unit must install two or more liners and a leachate collection and removal system above and between such liners, and operate the leachate collection and removal system, in accordance with § 264.301... case of any unit in which the liner and leachate collection system has been installed pursuant to the...

  6. 75 FR 8551 - Airworthiness Directives; Airbus Model A300, A300-600, and A310 Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-25

    ... when combined with an air duct leak, air conditioning system contamination or, if installed... combined with an air duct leak, air conditioning system contamination or, if installed, malfunction of the... some cases, the air conditioning system was contaminated with hydraulic mist. The leakage of the check...

  7. Existing Whole-House Solutions Case Study: Bay Ridge Gardens - Mixed Humid Affordable Multifamily Housing Deep Energy Retrofit, Annapolis, Maryland

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2013-10-01

    Under this project, the BA-PIRC research team evaluated the installation, measured performance, and cost-effectiveness of efficiency upgrade measures for a tenant-in-place deep energy retrofit at the Bay Ridge multifamily development in Annapolis, Maryland. The design and construction phase of the Bay Ridge project was completed in August 2012. This case study summarizes system commissioning, short-term test results, utility bill data analysis, and analysis of real-time data collected over a one-year period after the retrofit was complete.

  8. Using a personal digital assistant to document clinical pharmacy services in an intensive care unit.

    PubMed

    Lau, A; Balen, R M; Lam, R; Malyuk, D L

    2001-07-01

    Management Case Studies describe approaches to real-life management problems in health systems. Each installment is a brief description of a problem and how it was dealt with. The cases are intended to help readers deal with similar experiences in their own work sites. Problem solving, not hypothesis testing, is emphasized. Successful resolution of the management issue is not a criterion for publication--important lessons can be learned from failures, too.

  9. Novel use of flu surveillance data: Evaluating potential of sentinel populations for early detection of influenza outbreaks

    DOE PAGES

    Daughton, Ashlynn R.; Velappan, Nileena; Abeyta, Esteban; ...

    2016-07-08

    Influenza causes significant morbidity and mortality each year, with 2–8% of weekly outpatient visits around the United States for influenza-like-illness (ILI) during the peak of the season. Effective use of existing flu surveillance data allows officials to understand and predict current flu outbreaks and can contribute to reductions in influenza morbidity and mortality. Previous work used the 2009–2010 influenza season to investigate the possibility of using existing military and civilian surveillance systems to improve early detection of flu outbreaks. Results suggested that civilian surveillance could help predict outbreak trajectory in local military installations. To further test that hypothesis, we comparemore » pairs of civilian and military outbreaks in seven locations between 2000 and 2013. We find no predictive relationship between outbreak peaks or time series of paired outbreaks. This larger study does not find evidence to support the hypothesis that civilian data can be used as sentinel surveillance for military installations. We additionally investigate the effect of modifying the ILI case definition between the standard Department of Defense definition, a more specific definition proposed in literature, and confirmed Influenza A. We find that case definition heavily impacts results. In conclusion, this study thus highlights the importance of careful selection of case definition, and appropriate consideration of case definition in the interpretation of results.« less

  10. Novel use of flu surveillance data: Evaluating potential of sentinel populations for early detection of influenza outbreaks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daughton, Ashlynn R.; Velappan, Nileena; Abeyta, Esteban

    Influenza causes significant morbidity and mortality each year, with 2–8% of weekly outpatient visits around the United States for influenza-like-illness (ILI) during the peak of the season. Effective use of existing flu surveillance data allows officials to understand and predict current flu outbreaks and can contribute to reductions in influenza morbidity and mortality. Previous work used the 2009–2010 influenza season to investigate the possibility of using existing military and civilian surveillance systems to improve early detection of flu outbreaks. Results suggested that civilian surveillance could help predict outbreak trajectory in local military installations. To further test that hypothesis, we comparemore » pairs of civilian and military outbreaks in seven locations between 2000 and 2013. We find no predictive relationship between outbreak peaks or time series of paired outbreaks. This larger study does not find evidence to support the hypothesis that civilian data can be used as sentinel surveillance for military installations. We additionally investigate the effect of modifying the ILI case definition between the standard Department of Defense definition, a more specific definition proposed in literature, and confirmed Influenza A. We find that case definition heavily impacts results. In conclusion, this study thus highlights the importance of careful selection of case definition, and appropriate consideration of case definition in the interpretation of results.« less

  11. Novel Use of Flu Surveillance Data: Evaluating Potential of Sentinel Populations for Early Detection of Influenza Outbreaks

    PubMed Central

    Velappan, Nileena; Abeyta, Esteban; Priedhorsky, Reid; Deshpande, Alina

    2016-01-01

    Influenza causes significant morbidity and mortality each year, with 2–8% of weekly outpatient visits around the United States for influenza-like-illness (ILI) during the peak of the season. Effective use of existing flu surveillance data allows officials to understand and predict current flu outbreaks and can contribute to reductions in influenza morbidity and mortality. Previous work used the 2009–2010 influenza season to investigate the possibility of using existing military and civilian surveillance systems to improve early detection of flu outbreaks. Results suggested that civilian surveillance could help predict outbreak trajectory in local military installations. To further test that hypothesis, we compare pairs of civilian and military outbreaks in seven locations between 2000 and 2013. We find no predictive relationship between outbreak peaks or time series of paired outbreaks. This larger study does not find evidence to support the hypothesis that civilian data can be used as sentinel surveillance for military installations. We additionally investigate the effect of modifying the ILI case definition between the standard Department of Defense definition, a more specific definition proposed in literature, and confirmed Influenza A. We find that case definition heavily impacts results. This study thus highlights the importance of careful selection of case definition, and appropriate consideration of case definition in the interpretation of results. PMID:27391232

  12. Update on Geothermal Direct-Use Installations in the United States

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beckers, Koenraad J; Young, Katherine R; Snyder, Diana M.

    Direct-use of geothermal energy currently has limited penetration in the United States, with an estimated installed capacity of about 500 MWth, supplying on the order of 0.01% of the total annual U.S. heat demand (about 30 EJ). We see higher penetration levels in other countries such as Iceland (about 90%) and Hungary (2.5%). An updated database of geothermal direct-use systems in the U.S. has been compiled and analyzed, building upon the Oregon Institute of Technology (OIT) Geo-Heat Center direct-use database. Types of directuse applications examined include hot springs resorts and pools, aquaculture farms, greenhouses, and district heating systems, among others;more » power-generating facilities and ground-source heat pumps were excluded. Where possible, the current operation status, open and close dates, well data, and other technical data were obtained for each entry. The database contains 545 installations, of which 407 are open, 108 are closed, and 30 have an unknown status. Spas are the most common type of installation, accounting for 50% of installations by number. Aquaculture installations (46 out of 407 open installations) account for the largest percentage (26%) of installed capacity in operation (129 MWth out of 501 MWth). Historical deployment curves show the installed capacity significantly increased in the 1970s and 1980s mainly due to development of geothermal district heating, aquaculture, and greenhouse systems. Since the 2000s, geothermal direct-use development appears to have slowed, and the number of sites in operation decreased due to closures. Case studies reveal multiple barriers to geothermal direct-use implementation and operation, including 1) existence of an information gap among stakeholders, developers, and the general public, 2) competition from cheap natural gas, and 3) the family-owned, small-scale nature of businesses might result in discontinuation among generations.« less

  13. Assessment of electrical resistivity imaging for pre-tunneling geological characterization - A case study of the Qingdao R3 metro line tunnel

    NASA Astrophysics Data System (ADS)

    Li, Shucai; Xu, Shan; Nie, Lichao; Liu, Bin; Liu, Rentai; Zhang, Qingsong; Zhao, Yan; Liu, Quanwei; Wang, Houtong; Liu, Haidong; Guo, Qin

    2018-06-01

    Water inrush during tunneling is a significant problem in the underground infrastructure construction. Electrical resistivity imaging (ERI) is a technique that can detect and characterize a water body in an open fracture or fault by exploiting the resistivity contrast that exists between the water body and the surrounding materials. ERI is an efficient method for pre-tunneling geological characterization. In this study, a case study is presented in which tunnel-face and borehole ERI (TBERI) is performed by using the probe hole to detect a water body during tunnel construction. The construction site is a metro line site, situated in the city of Qingdao, China. Unlike the traditional cross-hole observation mode, TBERI only use a single borehole. The installation of injection electrodes inside the probe hole and the installation of measuring electrodes on the tunnel face is proposed as the observation mode. Furthermore, a numerical simulation is carried out before the real field experiment, and the simulation results show that the TBERI is capable of detecting a deeply buried water body. In addition, the water body in the field case is also identified by TBERI. The water body appears as a strongly conductive anomaly relative to the background materials. This study highlights the respective strengths and weaknesses of the TBERI for pre-tunneling geological characterization. This method is a relatively rapid means of investigating the studied area. This study clearly demonstrates the suitability of TBERI in a tunneling scenario.

  14. ALPHA: A Case Study in Upgrading.

    ERIC Educational Resources Information Center

    Granick, Leonard P. R.; And Others

    An industry-focused upgrading model, based upon job redesigns of entry-level and higher skill positions and a multi-step diagonal/vertical progression ladder was installed in a company having a 150-employee blue collar work force. The model provided for rapid promotion and wage increases of both present employees and new hires, supported by skills…

  15. Validation of in situ networks via field sampling: case study in the South Fork Experimental Watershed

    USDA-ARS?s Scientific Manuscript database

    The calibration and validation of soil moisture remote sensing products is complicated by the logistics of installing a soil moisture network for a long term period in an active landscape. Therefore, these stations are located along field boundaries or in non-representative sites with regards to so...

  16. Pollution Prevention Case Studies: Implications for Army Institutional Processes

    DTIC Science & Technology

    1994-06-01

    waste (FAMC), Optical Fabrication by switching from glass to Laboratory (OFL) plastiC lens production Fort Lewis FORSCOM Develop installation...Role of Compliance Pressures ...................................................................................... 51 6.8 Waste and Recyclables ...Anny Depot AMC Reduce chromium waste (CCAD) through change in Aluminum coating process Fitzsimmons Anny Medical Center HSC Decrease heavy metal

  17. A case study of the design, installation, and early performance of a nineteen-millimeter superpave mix.

    DOT National Transportation Integrated Search

    1999-07-01

    An attempt was made to design and construct a coarse matrix high binder (CMHB) mix. When the design of the CMHB mix was unsuccessful a coarse 19.0-mm Superpave mix was substituted. This report describes the attempted design of the CMHB mix, as well a...

  18. Occupational Health and Industrial Wind Turbines: A Case Study

    ERIC Educational Resources Information Center

    Rand, Robert W.; Ambrose, Stephen E.; Krogh, Carmen M. E.

    2011-01-01

    Industrial wind turbines (IWTs) are being installed at a fast pace globally. Researchers, medical practitioners, and media have reported adverse health effects resulting from living in the environs of IWTs. While there have been some anecdotal reports from technicians and other workers who work in the environs of IWTs, little is known about the…

  19. Technology vs the Academic Book Thief

    ERIC Educational Resources Information Center

    American School and University, 1972

    1972-01-01

    Three case studies describe successful installations of three leading book security manufacturers. Reports on a 92 percent book loss cut at West Leyden High School, Northlake, Illinois; a substantial savings and a loss cut at the Charles Stewart Mott Library, Flint, Michigan; and a 75 percent loss cut at Chabot College, Hayward, California. (EA)

  20. Alternative Fuels Data Center: North Carolina Transportation Data for

    Science.gov Websites

    ) 2,115 Source: BioFuels Atlas from the National Renewable Energy Laboratory Case Studies Video thumbnail CNG Installation a Boost Aug. 19, 2015 Video thumbnail for Biodiesel Offers an Easy Alternative for Fleets Biodiesel Offers an Easy Alternative for Fleets Aug. 18, 2015 Video thumbnail for Blue Skies

  1. Federal land management, carbon sequestration, and climate change in the Southeastern U.S.: a case study with fort benning

    USGS Publications Warehouse

    Zhao, S.; Liu, S.; Li, Z.; Sohl, Terry L.

    2010-01-01

    Land use activities can have a major impact on the temporal trendsandspatialpatternsofregionalland-atmosphereexchange of carbon. Federal lands generally have substantially different land management strategies from surrounding areas, and the carbon consequences have rarely been quantified and assessed. Using the Fort Benning Installation as a case study, we used the General Ensemble biogeochemical Modeling System (GEMS) to simulate and compare ecosystem carbon sequestration between the U.S. Army's Fort Benning and surrounding areas from 1992 to 2050. Our results indicate that the military installation sequestered more carbon than surrounding areas from 1992 to 2007 (76.7 vs 18.5 g C m-2 yr-1), and is projected to continue sequestering more carbon from 2008 to 2050 (75.7 vs 25.6 g C m-2 yr-1), mostly because of the proactive management approaches adopted on military training lands. Our results suggest that federal lands might play a positive and important role in sequestering and conserving atmospheric carbon because some anthropogenic disturbances (e.g., urbanization, forest harvesting, and agriculture) can be minimized or prevented on federal lands

  2. Projects without a purpose: Why a top down strategy to resilience matters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kingery, Kristine M.; Fowler, Kimberly M.; Harrove

    Energy resilience is a key focus of the current administration and Department of Defense (DoD) leaders, and is in the title of every energy conference session. Most case studies and success stories focus on resilience projects hardening systems or microgriding critical infrastructure. Some case studies focus on unique financing approaches to bring private sector innovation and increased investment to military installations. Many times, what initially look like innovative resilience projects, end as isolated systems or stranded infrastructure. This article will explore how the DoD can make greater strides advancing resilience objectives and ultimately developing projects that support installation mission readinessmore » by first focusing on top down strategies. The Army established energy and water security/resilience requirements, developed a comprehensive measurement framework, is evolving integrated planning approaches in collaboration with local communities, and is supporting project development activities across third-party and appropriated programs. The Army’s multi-year strategic energy and water security planning activities can provide helpful guidance to both the lifecycle of programs or individual projects, and ensure resilience projects both have and achieve a purpose.« less

  3. A combined experimental and numerical approach for the control and monitoring of the SPES target during operation at high temperature

    NASA Astrophysics Data System (ADS)

    Ballan, Michele; Manzolaro, Mattia; Meneghetti, Giovanni; Andrighetto, Alberto; Monetti, Alberto; Bisoffi, Giovanni; Prete, Gianfranco

    2016-06-01

    The SPES project at INFN-LNL aims at the production of neutron-rich Radioactive Ion Beams (RIBs) using the ISOL (Isotope Separation On Line) technique. A 40 MeV 200 μA proton beam will directly impinge a uranium carbide target, generating approximately 1013 fissions per second. The target system is installed under vacuum inside a water-cooled chamber, and have to maintain high working temperatures, close to 2000 °C. During operation the proton beam provides the heating power required to keep the target at the desired temperature level. As a consequence, its characteristics have to be strictly controlled in order to avoid undesired overheating. According to the original design of the control system, the proton beam can be suddenly interrupted in case of out of range vacuum or cooling water flow levels. With the aim to improve the reliability of the control system a set of temperature sensors has been installed close to the target. Their types and installation positions were defined taking into consideration the detailed information coming from a dedicated thermal-electric model that allowed to investigate the most critical and inaccessible target hot-spots. This work is focused on the definition and experimental validation of the aforementioned numerical model. Its results were used to appropriately install two type C thermocouples, a PT100 thermo-resistance and a residual primary beam current detector. In addition the numerical model will be used for the definition of appropriate thresholds for each installed temperature sensor, since it allows to define a relationship between the locally measured values with the overall calculated temperature field. In case of over temperatures the monitoring system will send warning signals or in case interrupt the proton beam.

  4. 30 CFR 250.442 - What are the requirements for a subsea BOP stack?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations...) When you drill with a subsea BOP stack, you must install the BOP system before drilling below surface casing. The District Manager may require you to install a subsea BOP system before drilling below the...

  5. Effect of distributed generation installation on power loss using genetic algorithm method

    NASA Astrophysics Data System (ADS)

    Hasibuan, A.; Masri, S.; Othman, W. A. F. W. B.

    2018-02-01

    Injection of the generator distributed in the distribution network can affect the power system significantly. The effect that occurs depends on the allocation of DG on each part of the distribution network. Implementation of this approach has been made to the IEEE 30 bus standard and shows the optimum location and size of the DG which shows a decrease in power losses in the system. This paper aims to show the impact of distributed generation on the distribution system losses. The main purpose of installing DG on a distribution system is to reduce power losses on the power system.Some problems in power systems that can be solved with the installation of DG, one of which will be explored in the use of DG in this study is to reduce the power loss in the transmission line. Simulation results from case studies on the IEEE 30 bus standard system show that the system power loss decreased from 5.7781 MW to 1,5757 MW or just 27,27%. The simulated DG is injected to the bus with the lowest voltage drop on the bus number 8.

  6. Method of making an aero-derivative gas turbine engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiebe, David J.

    A method of making an aero-derivative gas turbine engine (100) is provided. A combustor outer casing (68) is removed from an existing aero gas turbine engine (60). An annular combustor (84) is removed from the existing aero gas turbine engine. A first row of turbine vanes (38) is removed from the existing aero gas turbine engine. A can annular combustor assembly (122) is installed within the existing aero gas turbine engine. The can annular combustor assembly is configured to accelerate and orient combustion gasses directly onto a first row of turbine blades of the existing aero gas turbine engine. Amore » can annular combustor assembly outer casing (108) is installed to produce the aero-derivative gas turbine engine (100). The can annular combustor assembly is installed within an axial span (85) of the existing aero gas turbine engine vacated by the annular combustor and the first row of turbine vanes.« less

  7. Volume Stamping on Hydraulic Presses (Selected Portions),

    DTIC Science & Technology

    1981-07-02

    with press, it is recessary to connect one or the cther number of cylinders. In t1tis case freguently are created the adverse cornditicns of loading...also cn the- srecially creatid installation/sstting ur. for the percussive effect Af flcu cr the sa ]eqs/sp~cim~ns 1 FCOTNOTE IL. Work on the study of...pressure senscI [5]. Page 76. In the majority of thp cases in the hydroFressps the parameters change during the relatively lcnqg tire. Based on this

  8. Expert Elicitation Methods in Quantifying the Consequences of Acoustic Disturbance from Offshore Renewable Energy Developments.

    PubMed

    Donovan, Carl; Harwood, John; King, Stephanie; Booth, Cormac; Caneco, Bruno; Walker, Cameron

    2016-01-01

    There are many developments for offshore renewable energy around the United Kingdom whose installation typically produces large amounts of far-reaching noise, potentially disturbing many marine mammals. The potential to affect the favorable conservation status of many species means extensive environmental impact assessment requirements for the licensing of such installation activities. Quantification of such complex risk problems is difficult and much of the key information is not readily available. Expert elicitation methods can be employed in such pressing cases. We describe the methodology used in an expert elicitation study conducted in the United Kingdom for combining expert opinions based on statistical distributions and copula-like methods.

  9. USAF solar thermal applications case studies

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The potential of solar energy technologies to meet mission related applications for process heat was investigated. The reduction of the dependence of military installations on fossil fuels by promoting the use of more abundant resources where liquid hydrocarbons and natural gas are now used is examined. The evaluation and utilization of renewable energy systems to provide process heat and space heating are emphasized. The application of thermal energy systems is divided into four steps: (1) investigation of the potential operational cost effectiveness of selected thermal technologies; (2) selection of a site and preliminary design of point focussing solar thermal plant; (3) construction and test of an engineering prototype; and (4) installation and operation of a solar thermal energy plant.

  10. Brief: Field measurements of casing tension forces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quigley, M.S.; Lewis, D.B.; Boswell, R.S.

    1995-02-01

    Tension forces acting on individual casing joints were accurately measured during installation of 10,158 ft of 9 5/8-in. {times} 47-lbm/ft casing and 11,960 ft of 11 7/8-in. {times} 71.8-lbm/ft casing. A unique casing load table (CLT) weighed the casing string after the addition of each casing joint. Strain gauges attached inside the pin ends of instrumented casing joints (ICJ`s) directly measured tension force on those joints. A high-speed computer data-acquisition system (DAS) automatically recorded data from all the sensors. Several casing joints were intentionally subjected to extreme deceleration to determine upper limits for dynamic tension forces. Data from these testsmore » clearly show effects of wellbore friction and casing handling conditions. In every case, tension forces in the casing during maximum deceleration were considerably less than expected. In some cases, the highest tension forces occurred when the casing lifted out of the slips. Peak tension forces caused by setting the casing slips were typically no more than 5% greater than tension forces in the casing at rest. This dynamic amplification was far less than the 60% value used in the previous casing design method. Reducing the safety factor for installation loads has permitted use of lighter, less-expensive casing than dictated by older design criteria.« less

  11. Residential grid-connected photovoltaics adoption in north central Texas: Lessons from the Solarize Plano project

    NASA Astrophysics Data System (ADS)

    Jack, Katherine G.

    Residential Grid-Connected Photovoltaics (GPV) systems hold remarkable promise in their potential to reduce energy use, air pollution, greenhouse gas emissions, and energy costs to consumers, while also providing grid efficiency and demand-side management benefits to utilities. Broader adoption of customer-sited GPV also has the potential to transform the traditional model of electricity generation and delivery. Interest and activity has grown in recent years to promote GPV in north central Texas. This study employs a mixed methods design to better understand the status of residential GPV adoption in the DFW area, and those factors influencing a homeowner's decision of whether or not to install a system. Basic metrics are summarized, including installation numbers, distribution and socio-demographic information for the case study city of Plano, the DFW region, Texas, and the United States. Qualitative interview methods are used to gain an in-depth understanding of the factors influencing adoption for the Solarize Plano case study participants; to evaluate the effectiveness of the Solarize Plano program; and to identify concepts that may be regionally relevant. Recommendations are presented for additional research that may advance GPV adoption in north central Texas.

  12. Final Report: Assessment of Combined Heat and Power Premium Power Applications in California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Norwood, Zack; Lipman, Tim; Marnay, Chris

    2008-09-30

    This report analyzes the current economic and environmental performance of combined heat and power (CHP) systems in power interruption intolerant commercial facilities. Through a series of three case studies, key trade-offs are analyzed with regard to the provision of black-out ridethrough capability with the CHP systems and the resutling ability to avoid the need for at least some diesel backup generator capacity located at the case study sites. Each of the selected sites currently have a CHP or combined heating, cooling, and power (CCHP) system in addition to diesel backup generators. In all cases the CHP/CCHP system have a smallmore » fraction of the electrical capacity of the diesel generators. Although none of the selected sites currently have the ability to run the CHP systems as emergency backup power, all could be retrofitted to provide this blackout ride-through capability, and new CHP systems can be installed with this capability. The following three sites/systems were used for this analysis: (1) Sierra Nevada Brewery - Using 1MW of installed Molten Carbonate Fuel Cells operating on a combination of digestor gas (from the beer brewing process) and natural gas, this facility can produce electricty and heat for the brewery and attached bottling plant. The major thermal load on-site is to keep the brewing tanks at appropriate temperatures. (2) NetApp Data Center - Using 1.125 MW of Hess Microgen natural gas fired reciprocating engine-generators, with exhaust gas and jacket water heat recovery attached to over 300 tons of of adsorption chillers, this combined cooling and power system provides electricity and cooling to a data center with a 1,200 kW peak electrical load. (3) Kaiser Permanente Hayward Hospital - With 180kW of Tecogen natural gas fired reciprocating engine-generators this CHP system generates steam for space heating, and hot water for a city hospital. For all sites, similar assumptions are made about the economic and technological constraints of the power generation system. Using the Distributed Energy Resource Customer Adoption Model (DER-CAM) developed at the Lawrence Berkeley National Laboratory, we model three representative scenarios and find the optimal operation scheduling, yearly energy cost, and energy technology investments for each scenario below: Scenario 1 - Diesel generators and CHP/CCHP equipment as installed in the current facility. Scenario 1 represents a baseline forced investment in currently installed energy equipment. Scenario 2 - Existing CHP equipment installed with blackout ride-through capability to replace approximately the same capacity of diesel generators. In Scenario 2 the cost of the replaced diesel units is saved, however additional capital cost for the controls and switchgear for blackout ride-through capability is necessary. Scenario 3 - Fully optimized site analysis, allowing DER-CAM to specify the number of diesel and CHP/CCHP units (with blackout ride-through capability) that should be installed ignoring any constraints on backup generation. Scenario 3 allows DER-CAM to optimize scheduling and number of generation units from the currently available technologies at a particular site. The results of this analysis, using real data to model the optimal schedulding of hypothetical and actual CHP systems for a brewery, data center, and hospital, lead to some interesting conclusions. First, facilities with high heating loads will typically prove to be the most appropriate for CHP installation from a purely economic standpoint. Second, absorption/adsorption cooling systems may only be economically feasible if the technology for these chillers can increase above current best system efficiency. At a coefficient of performance (COP) of 0.8, for instance, an adsorption chiller paired with a natural gas generator with waste heat recovery at a facility with large cooling loads, like a data center, will cost no less on a yearly basis than purchasing electricity and natural gas directly from a utility. Third, at marginal additional cost, if the reliability of CHP systems proves to be at least as high as diesel generators (which we expect to be the case), the CHP system could replace the diesel generator at little or no additional cost. This is true if the thermal to electric (relative) load of those facilities was already high enough to economically justify a CHP system. Last, in terms of greenhouse gas emissions, the modeled CHP and CCHP systems provide some degree of decreased emissions relative to systems with less CHP installed. The emission reduction can be up to 10% in the optimized case (Scenario 3) in the application with the highest relative thermal load, in this case the hospital. Although these results should be qualified because they are only based on the three case studies, the general results and lessons learned are expected to be applicable across a broad range of potential and existing CCHP systems.« less

  13. Business Case Analysis for Replacing the Mazak 30Y Mill-Turn Machine in SM-39. Summary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Booth, Steven Richard; Dinehart, Timothy Grant; Benson, Faith Ann

    2015-03-19

    Business case studies are being looked at to support procurement of new machines and capital equipment in the SM-39 and TA-03-0102 machine shops. The first effort conducted economic analysis of replacing the Mazak 30Y Mill-Turn Machine located in SM-39. To determine the value of switching machinery, a baseline scenario was compared with a future scenario where new machinery was purchased and installed. The conditions under the two scenarios were defined via interviews with subject matter experts in terms of one-time and periodic costs. The results of the analysis were compiled in a life-cycle cost/benefit table. The costs of procuring, installing,more » and maintaining a new machine were balanced against the costs avoided by replacing older machinery. Productivity savings were included as a measure to show the costs avoided by being able to produce parts at a quicker and more efficient pace.« less

  14. Spectral ratio techniques as a tool for soil-structure interaction assessment

    NASA Astrophysics Data System (ADS)

    Ladina, C.; Lovati, S.; Marzorati, S.; Massa, M.

    2009-04-01

    In the last years many papers focused the attention on the estimation of site effects in correspondence of inhabited areas with the aim to evaluate if the free oscillations of a structure are able to modify the estimation of the fundamental frequency of the soil. In particular, a correct understanding of the source of a resonance amplification peak becomes relevant in the case where the frequencies of vibration of the buildings fall into the range where soil amplification is expected: in this case damage might increase in case of an earthquake due to an amplified structural response of the structure. In this work the results coming from ambient seismic noise measurements computed at 4 sites of Northern Italy, where seismic stations are installed inside buildings, are presented and discussed. The considered sites were selected in correspondence of very populated areas where both civil structures and industrial facilities are present: moreover in a such area, since the high level of background noise, where is not simple to find out site for a good seismic installation. The noise measurements were performed closed to 4 strong motion stations characterized by different types of installation: Bagolino station (BAG8), managed by the INGV (Italian National Institute for Geophysic and Vulcanology), installed in the basament of a primary school, with the sensor directly connected to the rock (limestone and dolomite); Aulla station (AUL), managed by the DPC (Italian Civil Protection), installed in the cellar of an ancient medieval fortress with the sensor directly connected to the rock (serpentine); Asolo station (ASO7), managed by the INGV, installed at the bottom of an ancient medieval fortress builded on an isolated hill (hard sandstone); in this case the sensor is installed on the foundations; Vobarno station (VOBA) managed by the INGV, located at the bottom of a primary school with the sensor installed on the foundations (plate foundation). The school, a two-stories RC structure, is built on lithological units characterized by alluvial deposits. All noise measurements, characterized by a minimum duration of 30 minutes (sampling rate 100 Hz), were performed using a Lennartz LE3D-5s seismometer (flat response 0.2 - 40 Hz) coupled with a 24 bits Reftek 130/01 digital recorder. To investigate the dynamic characterization of buildings both standard spectral ratio (SSR) and horizontal to vertical spectral ratio (HVNR) techniques were applied to the recorded data; in the first case two simultaneous measures, computed at the bottom and at the top of the structure were considered. For the stations where earthquakes recordings were available, the results from ambients noise were compared, to those obtained from earthquakes (HVSR). For all records the linear trend and the instrumental response were removed and a band-pass Butterworth 4 poles filter between 0.2 and 25 Hz was applied. Then each component of noise was windowed in time series of 120 s length (cosine taper 5%), the horizontal components were rotated between 0° and 175° with step of 5° and the power spectral density (PSD) were calculated using a Konno and Ohmachi (1998) window (b=20). Finally, for each considered azimuth average HVNRs were computed calculating for each time window the spectral ratio between the spectrum of the radial component over the spectrum of the vertical one. For earthquake the data processing were performed as described for noise but considering different portion of signal: 5 s and 15 s of S waves, starting 0.5 s before the S-waves picking, and 20 s of coda were selected. Also in this case for each selected window HVSR were calculated through a directional analysis as that described for HVNR. The results highlight the fundamental role of the installation. For BAG8 and AUL, where the sensors are directly installed on rock, the vibrations of the structure do not affect HVNR at the bottom, which show flat responses in the whole frequency range: in both cases the eigenfrequency of the building is given by the HVNR computed at the top of the structure. On the contrary for ASO7 and VOBA, where the sensors are directly connected with the foundations, both the amplification peaks between 5 and 9 Hz (ASO7) and between 5.5 and 7 Hz (VOBA) include the contribution of the free oscillations of the buildings. Particularly for VOBA, HVNRs performed outside building highlight possible soil-structure resonance effects in case of an earthquake.

  15. Calibration of Elasto-Magnetic Sensors on In-Service Cable-Stayed Bridges for Stress Monitoring.

    PubMed

    Cappello, Carlo; Zonta, Daniele; Laasri, Hassan Ait; Glisic, Branko; Wang, Ming

    2018-02-05

    The recent developments in measurement technology have led to the installation of efficient monitoring systems on many bridges and other structures all over the world. Nowadays, more and more structures have been built and instrumented with sensors. However, calibration and installation of sensors remain challenging tasks. In this paper, we use a case study, Adige Bridge, in order to present a low-cost method for the calibration and installation of elasto-magnetic sensors on cable-stayed bridges. Elasto-magnetic sensors enable monitoring of cable stress. The sensor installation took place two years after the bridge construction. The calibration was conducted in two phases: one in the laboratory and the other one on site. In the laboratory, a sensor was built around a segment of cable that was identical to those of the cable-stayed bridge. Then, the sample was subjected to a defined tension force. The sensor response was compared with the applied load. Experimental results showed that the relationship between load and magnetic permeability does not depend on the sensor fabrication process except for an offset. The determination of this offset required in situ calibration after installation. In order to perform the in situ calibration without removing the cables from the bridge, vibration tests were carried out for the estimation of the cables' tensions. At the end of the paper, we show and discuss one year of data from the elasto-magnetic sensors. Calibration results demonstrate the simplicity of the installation of these sensors on existing bridges and new structures.

  16. Calibration of Elasto-Magnetic Sensors on In-Service Cable-Stayed Bridges for Stress Monitoring

    PubMed Central

    Ait Laasri, Hassan; Glisic, Branko; Wang, Ming

    2018-01-01

    The recent developments in measurement technology have led to the installation of efficient monitoring systems on many bridges and other structures all over the world. Nowadays, more and more structures have been built and instrumented with sensors. However, calibration and installation of sensors remain challenging tasks. In this paper, we use a case study, Adige Bridge, in order to present a low-cost method for the calibration and installation of elasto-magnetic sensors on cable-stayed bridges. Elasto-magnetic sensors enable monitoring of cable stress. The sensor installation took place two years after the bridge construction. The calibration was conducted in two phases: one in the laboratory and the other one on site. In the laboratory, a sensor was built around a segment of cable that was identical to those of the cable-stayed bridge. Then, the sample was subjected to a defined tension force. The sensor response was compared with the applied load. Experimental results showed that the relationship between load and magnetic permeability does not depend on the sensor fabrication process except for an offset. The determination of this offset required in situ calibration after installation. In order to perform the in situ calibration without removing the cables from the bridge, vibration tests were carried out for the estimation of the cables’ tensions. At the end of the paper, we show and discuss one year of data from the elasto-magnetic sensors. Calibration results demonstrate the simplicity of the installation of these sensors on existing bridges and new structures. PMID:29401751

  17. The importance of user centered design methods applied to the design of a new workstation: a case study.

    PubMed

    Duschenes, Ronaldo; Mendes, Andressa; Betiol, Adriana; Barreto, Suzana

    2012-01-01

    This paper presents a case study of the application of user centered design methodologies in the product development for a line of ergonomic office furniture. The study aimed to analyze the experience of using a workstation from the perspective of two groups of users, installers and end users. The observation of users in their natural context of use not only allowed the development team to identify key needs and strategies of the users, transforming them into design solutions, but mainly it warned them of the importance and impact of user involvement in the product development cycle.

  18. Reading Teachers' Beliefs and Utilization of Computer and Technology: A Case Study

    ERIC Educational Resources Information Center

    Remetio, Jessica Espinas

    2014-01-01

    Many researchers believe that computers have the ability to help improve the reading skills of students. In an effort to improve the poor reading scores of students on state tests, as well as improve students' overall academic performance, computers and other technologies have been installed in Frozen Bay School classrooms. As the success of these…

  19. Existing Whole-House Solutions Case Study: Habitat for Humanity South Sarasota County, Venice, Florida

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2011-11-01

    PNNL and Calcs Plus helped the South Sarasota County Florida Habitat for Humanity retrofit a 1978 single-story home by stripping old drywall, air sealing concrete block walls, and installing rigid insulation, furring strips, and new drywall. The attic was sealed and insulated with spray foam to house a new heat pump.

  20. 30 CFR 250.1608 - Well casing and cementing.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Well casing and cementing. 250.1608 Section 250.1608 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND... inch (psi). (3) The lessee shall install casing designed to withstand the anticipated stresses imposed...

  1. Surgical Treatment, Oral Rehabilitation, and Orthognathic Surgery After Failure of Pharmacologic Treatment of Central Giant Cell Lesion: A Case Report.

    PubMed

    Maia Nogueira, Renato Luiz; Osterne, Rafael Lima Verde; Cavalcante, Roberta Barroso; Abreu, Ricardo Teixeira

    2016-12-01

    Although pharmacologic treatments for central giant cell lesions have gained much emphasis, these treatment modalities do not always have successful outcomes, and surgical treatment may be necessary. The purpose of the present study was to report a case of aggressive central giant cell lesion initially treated by nonsurgical methods without satisfactory results, necessitating segmental mandibular resection for definitive treatment and oral rehabilitation. A 20-year-old woman was diagnosed with an aggressive central giant cell lesion in the mandible. The patient was first treated with intralesional corticosteroid injections. Subsequently, the lesion increased in size. Therefore, a second pharmacologic treatment was proposed with salmon calcitonin nasal spray, but no signs of a treatment response were noted. Because of the lack of response, surgical excision was performed, and a mandibular reconstruction plate was installed. At 12 months after surgical resection, the patient underwent mandibular reconstruction with bone grafts. After 6 months, 7 dental implants were installed, and fixed prostheses were made. After installation of the prostheses, the patient experienced persistent mandibular laterognathism, and a mandibular orthognathic surgery was performed to correct the laterognathia. The follow-up examination 4 years after orthognathic surgery showed no signs of recurrence and good facial symmetry. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Analysis Impact of Distributed Generation Injection to Profile of Voltage and Short-Circuit Fault in 20 kV Distribution Network System

    NASA Astrophysics Data System (ADS)

    Mulyadi, Y.; Sucita, T.; Rahmawan, M. D.

    2018-01-01

    This study was a case study in PT. PLN (Ltd.) APJ Bandung area with the subject taken was the installation of distributed generation (DG) on 20-kV distribution channels. The purpose of this study is to find out the effect of DG to the changes in voltage profile and three-phase short circuit fault in the 20-kV distribution system with load conditions considered to be balanced. The reason for this research is to know how far DG can improve the voltage profile of the channel and to what degree DG can increase the three-phase short circuit fault on each bus. The method used in this study was comparing the simulation results of power flow and short-circuit fault using ETAP Power System software with manual calculations. The result obtained from the power current simulation before the installation of DG voltage was the drop at the end of the channel at 2.515%. Meanwhile, the three-phase short-circuit current fault before the DG installation at the beginning of the channel was 13.43 kA. After the installation of DG with injection of 50%, DG power obtained voltage drop at the end of the channel was 1.715% and the current fault at the beginning network was 14.05 kA. In addition, with injection of 90%, DG power obtained voltage drop at the end of the channel was 1.06% and the current fault at the beginning network was 14.13%.

  3. Measuring the Hydraulic Effectiveness of Low Impact Development Practices in a Heavily Urbanised Environment: A Case Study from London, UK

    NASA Astrophysics Data System (ADS)

    El Hattab, M. H.; Vernon, D.; Mijic, A.

    2017-12-01

    Low impact development practices (LID) are deemed to have a synergetic effect in mitigating urban storm water flooding. Designing and implementing effective LID practices require reliable real-life data about their performance in different applications; however, there are limited studies providing such data. In this study an innovative micro-monitoring system to assess the performance of porous pavement and rain gardens as retrofitting technologies was developed. Three pilot streets in London, UK were selected as part of Thames Water Utilities Limited's Counters Creek scheme. The system includes a V-notch weir installed at the outlet of each LID device to provide an accurate and reliable quantification over a wide range of discharges. In addition to, a low flow sensor installed downstream of the V-notch to cross-check the readings. Having a flow survey time-series of the pre-retrofitting conditions from the study streets, extensive laboratory calibrations under different flow conditions depicting the exact site conditions were performed prior to installing the devices in the field. The micro-monitoring system is well suited for high-resolution temporal monitoring and enables accurate long-term evaluation of LID components' performance. Initial results from the field validated the robustness of the system in fulfilling its requirements.

  4. Modelling of different measures for improving removal in a stormwater pond.

    PubMed

    German, J; Jansons, K; Svensson, G; Karlsson, D; Gustafsson, L G

    2005-01-01

    The effect of retrofitting an existing pond on removal efficiency and hydraulic performance was modelled using the commercial software Mike21 and compartmental modelling. The Mike21 model had previously been calibrated on the studied pond. Installation of baffles, the addition of culverts under a causeway and removal of an existing island were all studied as possible improvement measures in the pond. The subsequent effect on hydraulic performance and removal of suspended solids was then evaluated. Copper, cadmium, BOD, nitrogen and phosphorus removal were also investigated for that specific improvement measure showing the best results. Outcomes of this study reveal that all measures increase the removal efficiency of suspended solids. The hydraulic efficiency is improved for all cases, except for the case where the island is removed. Compartmental modelling was also used to evaluate hydraulic performance and facilitated a better understanding of the way each of the different measures affected the flow pattern and performance. It was concluded that the installation of baffles is the best of the studied measures resulting in a reduction in the annual load on the receiving lake by approximately 8,000 kg of suspended solids (25% reduction of the annual load), 2 kg of copper (10% reduction of the annual load) and 600 kg of BOD (10% reduction of the annual load).

  5. Final Technical Report for EE0006091: H2Pump Hydrogen Recycling System Demonstration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Staudt, Rhonda

    The objective of this project is to demonstrate the product readiness and to quantify the benefits and customer value proposition of H2Pump’s Hydrogen Recycling System (HRS-100™) by installing and analyzing the operation of multiple prototype 100-kg per day systems in real world customer locations. The data gathered will be used to measure reliability, demonstrate the value proposition to customers, and validate our business model. H2Pump will install, track and report multiple field demonstration systems in industrial heat treating and semi-conductor applications. The customer demonstrations will be used to develop case studies and showcase the benefits of the technology to drivemore » market adoption.« less

  6. Seismic detection system for blocking the dangerous installations in case of strong earthquake occurrence

    NASA Astrophysics Data System (ADS)

    Ghica, Daniela; Corneliu Rau, Dan; Ionescu, Constantin; Grigore, Adrian

    2010-05-01

    During the last 70 years, four major earthquakes occurred in the Vrancea seismic area affected Romania territory: 10 November 1940 (Mw = 7.7, 160 km depth), 4 March 1977 (Mw = 7.5, 100 km depth), 30 August 1986 (Mw = 7.2, 140 km depth), 30 May 30 1990 (Mw = 6.9, 80 km depth). Romania is a European country with significant seismicity. So far, the 1977 event had the most catastrophic consequences: about 33,000 residences were totally destroyed or partially deteriorated, 1,571 people dies and another 11,300 were injured. Moreover, 61 natural-gas pipelines were damaged, causing destructive fires. The total losses were estimated at 3 mld. U.S. dollars. Recent studies clearly pointed out that in case of a strong earthquake occurrence in Vrancea region (Ms above 7), the biggest danger regarding the major cities comes from explosions and fires started immediately after the earthquake, and the most important factor of risk are the natural gas distribution networks. The damages are strongly amplified by the fact that, simultaneously, water and electric energy lines distributions are damaged too, making impossible the efficient firemen intervention, for localizing the fire sources. Presently, in Romania safe and efficient accepted solutions for improving the buildings securing, using antiseismic protection of the dangerous installations as natural-gas pipelines are not available. Therefore, we propose a seismic detection system based on a seismically actuated gas shut-off valve, which is automatically shut down in case of a seismic shock. The device is intended to be installed in the natural-gas supply line outside of buildings, as well at each user (group of users), inside of the buildings. The seismic detection system for blocking the dangerous installations in case of a strong earthquake occurrence was designed on the basis of 12 criteria enforced by the US regulations for seismic valves, aimed to eliminate the critical situations as fluids and under pressure gases leakage caused by the seismic shocks. The system is mechanical actuated (no external power sources needed) and consists of two main parts: the element for energy accumulation, i.e. elicoidal spring, and the blocking system for shut-off and secured positioning of the installation. The criteria of the energy accumulating and storing are successfully accomplished by the torsion spring: the exact amount of needed mechanical energy is stored, the certain rotation couple is ensured, the mechanical energy is not influenced by the external factors (temperature, humidity, radiation etc.), the energy stored is time-stable and no energy loss is possible during the operation. The device is self-functioning, independent of any energy source, and the mechanism used in the locking system is not involving gravitational field; moreover, the blocking down energy is stored and adjustable, being possible to overrun several times the minimum necessary energy needed for locking the system, with a high level of stability. Additionally, the blocking system of the seismic valve remains closed (visibly) until the device is manually unblocked and armed, after a preliminary checking of the full installation functionality. The device conception and execution allow a very stable operation for more than 30 years. Since the fluid is not flowing through the blocking mechanism, the system can be successfully used for: natural gases installations, protection of GPL tanks, corrosive poisonous substances, polluting agents etc.

  7. WASTE MINIMIZATION AUDIT REPORT: CASE STUDIES OF MINIMIZATION OF SOLVENT WASTES AND ELECTROPLATING WASTES AT A DOD (DEPARTMENT OF DEFENSE) INSTALLATION

    EPA Science Inventory

    The report results of a waste minimization audit carried out in 1987 at a tank reconditioning facility operated by the DOD. The audit team developed recommendations for reducing the generation FOO6 wastewater treatment sludge, and FOO2, and FOO4 solvent wastes. In addition to det...

  8. The Impact of Public Spending in a Low-Income Rural Area: A Case Study of Fort Leonard Wood, Mo.

    ERIC Educational Resources Information Center

    Holmes, O. Wendell

    The economic effects of Government spending at public installations in rural areas was investigated. Fort Leonard Wood, Missouri, was chosen because of its location in a low-income rural area with relatively high outmigration, a declining agricultural industry base, and few employment opportunities. All of the data relating to Government spending…

  9. Schools Going Solar: A Guide to Schools Enjoying the Power of Solar Energy. Volume 2.

    ERIC Educational Resources Information Center

    Hitchcock, Susan Tyler

    This companion document updates an April 1998 volume on designing schools to use solar energy as a power source. Volume 2 presents numerous case studies of solar installations in new and existing schools across the United States and Europe, updates and presents new examples of solar education programs, and offers an updated resource listing of…

  10. Case study of landfill leachate recirculation using small-diameter vertical wells.

    PubMed

    Jain, Pradeep; Ko, Jae Hac; Kumar, Dinesh; Powell, Jon; Kim, Hwidong; Maldonado, Lizmarie; Townsend, Timothy; Reinhart, Debra R

    2014-11-01

    A case study of landfill liquids addition using small diameter (5 cm) vertical wells is reported. More than 25,000 m(3) of leachate was added via 134 vertical wells installed 3 m, 12 m, and 18 m deep over five years in a landfill in Florida, US. Liquids addition performance (flow rate per unit screen length per unit liquid head) ranged from 5.6×10(-8) to 3.6×10(-6) m(3) s(-1) per m screen length per m liquid head. The estimated radial hydraulic conductivity ranged from 3.5×10(-6) to 4.2×10(-4) m s(-1). The extent of lateral moisture movement ranged from 8 to 10 m based on the responses of moisture sensors installed around vertical well clusters, and surface seeps were found to limit the achievable liquids addition rates, despite the use of concrete collars under a pressurized liquids addition scenario. The average moisture content before (51 samples) and after (272 samples) the recirculation experiments were 23% (wet weight basis) and 45% (wet weight basis), respectively, and biochemical methane potential measurements of excavated waste indicated significant (p<0.025) decomposition. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Bathroom scald burns in Queensland Children.

    PubMed

    Gole, Hobia; Kimble, Roy; Stockton, Kellie

    2017-05-01

    To evaluate the current characteristics of bathroom scald injuries in Queensland Children. Data was collected from patients who presented with a bathroom scald injury to the Stuart Pegg Paediatric Burns Centre at the Royal Children's Hospital and Lady Cilento Children's Hospital, Brisbane from January 2013 to December 2014. Bathroom scald burns represented 2.6% of total burns cases with an inpatient rate of 39%. The family home is the location of injury in 84% of cases and in 79% the patient was aged 2 years of age or younger. Total body surface area ranged from 0.5% to 20% with a median of 1.75% (IQR 0.63, 3.38%). In our study 8% of patients underwent grafting and 24% received follow up for scar management. Injuries occurred in rental properties in 47% of tempering valve survey respondents. The rate of installation of tempering valves was 23%. Bathroom scald burns continue to be over-represented in inpatient data. Tempering valves were not consistently installed after injury, this intervention would require further legislation to be an effective prevention strategy. This study provides important insights into paediatric bathroom scald injuries and will assist with the development of prevention strategies. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  12. 40 CFR 146.22 - Construction requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... caliper logs before casing is installed; and (B) A cement bond, temperature, or density log after the...; and (C) A cement bond, temperature, or density log after the casing is set and cemented. (g) At a... drinking water. The casing and cement used in the construction of each newly drilled well shall be designed...

  13. Automatic Publication of a MIS Product to GeoNetwork: Case of the AIS Indexer

    DTIC Science & Technology

    2012-11-01

    installation and configuration The following instructions are for installing and configuring the software packages Java 1.6 and MySQL 5.5 which are...An Automatic Identification System (AIS) reception indexer Java application was developed in the summer of 2011, based on the work of Lapinski and...release; distribution unlimited 13. SUPPLEMENTARY NOTES 14. ABSTRACT An Automatic Identification System (AIS) reception indexer Java application was

  14. Influence of forces acting on side of machine on precision machining of large diameter holes

    NASA Astrophysics Data System (ADS)

    Fedorenko, M. A.; Bondarenko, J. A.; Sanina, T. M.

    2018-03-01

    One of the most important factors that increase efficiency, durability and reliability of rotating units is precision installation, preventive maintenance work, timely replacing of a failed or worn components and assemblies. These works should be carried out in the operation of the equipment, as the downtime in many cases leads to large financial losses. Stop of one unit of an industrial enterprise can interrupt the technological chain of production, resulting in a possible stop of the entire equipment. Improving the efficiency and optimization of the repair process increases accuracy of installation work when installing equipment, conducting restoration under operating conditions relevant for enterprises of different industries because it eliminates dismantling the equipment, sending it to maintenance, the expectation of equipment return, the new installation with the required quality and accuracy of repair.

  15. Grid-connected photovoltaic (PV) systems with batteries storage as solution to electrical grid outages in Burkina Faso

    NASA Astrophysics Data System (ADS)

    Abdoulaye, D.; Koalaga, Z.; Zougmore, F.

    2012-02-01

    This paper deals with a key solution for power outages problem experienced by many African countries and this through grid-connected photovoltaic (PV) systems with batteries storage. African grids are characterized by an insufficient power supply and frequent interruptions. Due to this fact, users who especially use classical grid-connected photovoltaic systems are unable to profit from their installation even if there is sun. In this study, we suggest the using of a grid-connected photovoltaic system with batteries storage as a solution to these problems. This photovoltaic system works by injecting the surplus of electricity production into grid and can also deliver electricity as a stand-alone system with all security needed. To achieve our study objectives, firstly we conducted a survey of a real situation of one African electrical grid, the case of Burkina Faso (SONABEL: National Electricity Company of Burkina). Secondly, as study case, we undertake a sizing, a modeling and a simulation of a grid-connected PV system with batteries storage for the LAME laboratory at the University of Ouagadougou. The simulation shows that the proposed grid-connected system allows users to profit from their photovoltaic installation at any time even if the public electrical grid has some failures either during the day or at night.

  16. Student Team Achievement Divisions: Its Effect on Electrical Motor Installation Knowledge Competence

    NASA Astrophysics Data System (ADS)

    Hanafi, Ahmad; Basuki, Ismet

    2018-04-01

    Student team achievement division (STAD) was an active learning strategy with the small group inside of the classroom members. The students would work in small heterogeneous groups (of five to six members) and help one another to comprehend the material given. To achieve the objectives of the study, this research aims to know the effect of STAD on competence of electrical motor installation. The objective of the student competence was knowledge competence. The data was collected from 30 students. the participants were the students of second class at electrical installation techniques, SMKN 1 Pungging Indonesia. The design of empirical test in this research was one shot case study. The result of knowledge test would be compared by criteria for minimum competence, which was 75. Knowledge competence was analyzed with one sample t test technique. From the analysis got average 84.93, which meant average of student competence had reached criteria for minimum competence. From that analyze, It could be concluded that STAD was effective on electrical motor installation knowledge competence. STAD could grow student motivation to learn better than other models. But, in the application of cooperative learning teacher should prepare carefully before the learning process to avoid problems that could arise during group learning such as students who were less active in the groups. The problem could be resolved by away the teachers took around to check each group. It was felt could minimize the problems.

  17. A Framework for Statewide Analysis of Site Suitability, Energy Estimation, Life Cycle Costs, Financial Feasibility and Environmental Assessment of Wind Farms: A Case Study of Indiana

    NASA Astrophysics Data System (ADS)

    Kumar, Indraneel

    In the last decade, Midwestern states including Indiana have experienced an unprecedented growth in utility scale wind energy farms. For example, by end of 2013, Indiana had 1.5 GW of wind turbines installed, which could provide electrical energy for as many as half-a-million homes. However, there is no statewide systematic framework available for the evaluation of wind farm impacts on endangered species, required necessary setbacks and proximity standards to infrastructure, and life cycle costs. This research is guided to fill that gap and it addresses the following questions. How much land is suitable for wind farm siting in Indiana given the constraints of environmental, ecological, cultural, settlement, physical infrastructure and wind resource parameters? How much wind energy can be obtained? What are the life cycle costs and economic and financial feasibility? Is wind energy production and development in a state an emission free undertaking? The framework developed in the study is applied to a case study of Indiana. A fuzzy logic based AHP (Analytic Hierarchy Process) spatial site suitability analysis for wind energy is formulated. The magnitude of wind energy that could be sited and installed comprises input for economic and financial feasibility analysis for 20-25 years life cycle of wind turbines in Indiana. Monte Carlo simulation is used to account for uncertainty and nonlinearity in various costs and price parameters. Impacts of incentives and cost variables such as production tax credits, costs of capital, and economies of scale are assessed. Further, an economic input-output (IO) based environmental assessment model is developed for wind energy, where costs from financial feasibility analysis constitute the final demand vectors. This customized model for Indiana is used to assess emissions for criteria air pollutants, hazardous air pollutants and greenhouse gases (GHG) across life cycle events of wind turbines. The findings of the case study include that, Indiana has adequate suitable land area available to locate wind farms with installed capacity between 11 and 51 GW if 100 meters high turbines are used. For a 1.5 MW standard wind turbine, financial feasibility analysis shows that production tax credits and property tax abatements are helpful for financial success in Indiana. Also, the wind energy is not entirely emission free if life cycle events of wind turbine manufacturing, production, installation, construction and decommissioning are considered. The research developed a replicable and integrated framework for statewide life cycle analysis of wind energy production accounting for uncertainty into the analyses. Considering the complexity of life cycle analysis and lack of state specific data on performance of wind turbines and wind farms, this study should be considered an intermediate step.

  18. Energy Optimization Modeling of Geothermal Power Plant (Case Study: Darajat Geothermal Field Unit III)

    NASA Astrophysics Data System (ADS)

    Sinaga, R. H. M.; Darmanto, P. S.

    2016-09-01

    Darajat unit III geothermal power plant is developed by PT. Chevron Geothermal Indonesia (CGI). The plant capacity is 121 MW and load 110%. The greatest utilization power is consumed by Hot Well Pump (HWP) and Cooling Tower Fan (CTF). Reducing the utility power can be attempted by utilizing the wet bulb temperature fluctuation. In this study, a modelling process is developed by using Engineering Equation Solver (EES) software version 9.430.The possibility of energy saving is indicated by Specific Steam Consumption (SSC) net in relation to wet bulb temperature fluctuation from 9°C up to 20.5°C. Result shows that the existing daily operation reaches its optimum condition. The installation of Variable Frequency Drive (VFD) could be applied to optimize both utility power of HWP and CTF. The highest gain is obtained by VFD HWP installation as much as 0.80% when wet bulb temperature 18.5 °C.

  19. Progress in distributed fiber optic temperature sensing

    NASA Astrophysics Data System (ADS)

    Hartog, Arthur H.

    2002-02-01

    The paper reviews the adoption of distributed temperature sensing (DTS) technology based on Raman backscatter. With one company alone having installed more than 400 units, the DTS is becoming accepted practice in several applications, notably in energy cable monitoring, specialised fire detection and oil production monitoring. The paper will provide case studies in these applications. In each case the benefit (whether economic or safety) will be addressed, together with key application engineering issues. The latter range from the selection and installation of the fibre sensor, the specific performance requirements of the opto-electronic equipment and the issues of data management. The paper will also address advanced applications of distributed sensing, notably the problem of monitoring very long ranges, which apply in subsea DC energy cables or in subsea oil wells linked to platforms through very long (e.g. 30km flowlines). These applications are creating the need for a new generation of DTS systems able to achieve measurements at up to 40km with very high temperature resolution, without sacrificing spatial resolution. This challenge is likely to drive the development of new concepts in the field of distributed sensing.

  20. Application of a Resilience Framework to Military Installations: A Methodology for Energy Resilience Business Case Decisions

    DTIC Science & Technology

    2016-10-04

    analysis (due to site-level evaluations), but could be added in the future, include: wind turbines (the installations we visited were not interested due...procurement, operation, maintenance , testing, and fueling of the generators, detailed inventory and cost data is difficult to obtain. The DPW is often...understaffed, leading to uneven testing and maintenance of the equipment despite their best efforts. The reliability of these generators is typically

  1. Historic Properties Report: Harry Diamond Laboratories, Maryland and Satellite Installations Woodbridge Research Facility, Virginia and Blossom Point Field Test Facility, Maryland

    DTIC Science & Technology

    1984-07-01

    HISTORIC PROPERTIES REPORT HARRY DIAMOND LABORATORIES, MARYLAND ,’ / .’- AND SATELLITE INSTALLATIONS ~WOODBRIDGE RESEARCH FACILITY, VIRGINIA AND ,00... report . METHODOLOGY 1. Documentary Research Harry Diamond Laboratories (HDL) and its two satellite facilities at Woodbridge and Blossom Point are...drawings, and written history. Interagency Archeological Services and U.S. Army, Harry Diamond Laboratories. 106 Case Report and Mitigation Plan: Ballast

  2. Fixation of the stressed state of glass plates by coating them with thin films using a plasma focus installation

    NASA Astrophysics Data System (ADS)

    Kolokoltsev, V. N.; Degtiarev, V. F.; Borovitskaya, I. V.; Nikulin, V. Ya.; Peregudova, E. N.; Silin, P. V.; Eriskin, A. A.

    2018-01-01

    Elastic deformation in transparent mediums is usually studied by the photoelasticity method. For opaque mediums the method of film coating and strain gauge method are used. After the external load was removed, the interference pattern corresponding to elastic deformation of the material disappears. It is found that the elastic deformation state of the thin glass plate under the action of concentrated load can be fixed during the deposition of a thin metal film. Deposition of thin copper films was carried out by passing of plasma through the copper tube installed inside the Plasma Focus installation. After removing of the load, interference pattern on the glass plates was observed in the form of Newton’s rings and isogers in non-monochromatic light on the CCD scanners which uses uorescent lamps with cold cathode. It is supposed that the copper film fixes the relief of the surface of the glass plate at the time of deformation and saves it when the load is removed. In the case of a concentrated load, this relief has the shape of a thin lens of large radius. For this reason, the interference of coherent light rays in a thin air gap between the glass of the scanners atbed and the lens surface has the shape of Newton's rings. In this case, when scanning the back side of the plate, isogyres are observed. The presented method can be used in the analysis of the mechanical stress in a various optical elements.

  3. Mom told me scary things about this animal: parents installing fear beliefs in their children via the verbal information pathway.

    PubMed

    Muris, Peter; van Zwol, Lisanne; Huijding, Jorg; Mayer, Birgit

    2010-04-01

    This study investigated whether fear beliefs can be installed in children after parents had received negatively tinted information about a novel stimulus. Parents of children aged 8-13 years (N = 88) were presented with negative, positive, or ambiguous information about an unknown animal and then given a number of open-ended vignettes describing confrontations with the animal with the instruction to tell their children what would happen in these situations. Results indicated that children's fear beliefs were influenced by the information that was provided to the parent. That is, parents who had received negative information provided more threatening narratives about the animal and hence installed higher levels of fear beliefs in their children than parents who had received positive information. In the case of ambiguous information, the transmission of fear was dependent on parents' trait anxiety levels. More precisely, high trait anxious parents told more negative stories about the unknown animal, which produced higher fear levels in children. 2009 Elsevier Ltd. All rights reserved.

  4. Implementing Stakeholders' Access to Expertise: Experimenting on Nuclear Installations' Safety Cases - 12160

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gilli, Ludivine; Charron, Sylvie

    2012-07-01

    In 2009 and 2010, the Institute for Nuclear Safety and Radiation Protection (IRSN) led two pilot actions dealing with nuclear installations' safety cases. One concerned the periodical review of the French 900 MWe nuclear reactors, the other concerned the decommissioning of a workshop located on the site of Areva's La Hague fuel-reprocessing plant site in Northwestern France. The purpose of both these programs was to test ways for IRSN and a small number of stakeholders (Non-Governmental Organizations (NGOs) members, local elected officials, etc.) to engage in technical discussions. The discussions were intended to enable the stakeholders to review future applicationsmore » and provide valuable input. The test cases confirmed there is a definite challenge in successfully opening a meaningful dialogue to discuss technical issues, in particular the fact that most expertise reports were not public and the conflict that exists between the contrary demands of transparency and confidentiality of information. The test case also confirmed there are ways to further improvement of stakeholders' involvement. (authors)« less

  5. Solar-heated municipal swimming pools, a case study: Dade County, Florida

    NASA Astrophysics Data System (ADS)

    Levin, M.

    1981-09-01

    The installation of a solar energy system to heat the water in the swimming pool in one of Dade County, Florida's major parks is described. The mechanics of solar heated swimming pools are explained. The solar heating system consists of 216 unglazed polypropylene tube collectors, a differential thermostat, and the distribution system. The systems performance and economics as well as future plants are discussed.

  6. Economic and environmental benefits of community-scale cordwood hydronic heaters in Alaska—three case studies

    Treesearch

    David L. Nicholls; Allen M. Brackley; Daniel J. Parrent

    2015-01-01

    Over the past decade, the use of wood for thermal energy in Alaska has grown significantly. Since 2000, nearly 30 new thermal wood-energy installations in Alaska have been established. Cordwood units, burning primarily firewood and other forms of roundwood, have played an integral part in this success and are well suited to many rural communities in Alaska. In this...

  7. Repair and Rehabilitation of Dams: Case Studies

    DTIC Science & Technology

    1999-09-01

    with fiber - reinforced , acrylic- polymer modi- fied concrete (FRAPMC) and eliminating leakage into the trunnion recesses. FRAPMC consists of mortar...coarse aggregate, and reinforcement fibers . It is mixed in a mortar mixer as a two-component system consisting of a liquid polymer emulsion of...seat was removed and replaced with fiber - reinforced , acrylic- polymer modified concrete (FRAPMC). New bridge seats were installed, allowing for more

  8. Building America Case Study: Simplified Air Distribution, Desuperheaters, and Sub-Slab Geothermal Heat Exchangers, Pittsburgh, Pennsylvania

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab.

  9. [Breast cancer screening process indicators in Mexico: a case study].

    PubMed

    Uscanga-Sánchez, Santos; Torres-Mejía, Gabriela; Ángeles-Llerenas, Angélica; Domínguez-Malpica, Raúl; Lazcano-Ponce, Eduardo

    2014-01-01

    To identify, measure and compare the performance indicators of productivity, effective access and quality service for the early detection breast cancer program in Mexico. By means of a study case based on the 2011 Women Cancer Information System (SICAM), the indicators were measured and compared with the Mexican official standard NOM-041-SSA2-2011 and international standards. The analysis showed insufficient installed capacity (37%), low coverage in screening (15%), diagnostic evaluation (16%), biopsy (44%) and treatment (57%), and very low effectiveness in confirmed cases by the total number of screening mammograms performed (0.04%). There was no information available, from SICAM, to estimate the rest of the indicators proposed. Efficient health information systems are required in order to monitor indicators and generate performance observatories of screening programs.

  10. Realized field tests

    NASA Astrophysics Data System (ADS)

    Cordes, V.

    1983-09-01

    Three solar generator projects in developing countries are discussed. A brackish water desalination unit was developed and built. A 2.4 kW solar generator supplies the desalination unit which produces 1.5 cum drinking water per day, and the pump installed for a hoisting depth of 20 m. The unit switches on if the solar energy is sufficiently high; a 160 Ahr battery guarantees constant operation. A photovoltaically supplied UHF transmitter was installed. A 3.6 kW solar generator and a battery make transmitter and air traffic warning illumination self-sufficient. A small diesel generator is installed for emergency cases. Experience shows that solar generator (4 kW) and battery have to be enlarged. An emergency solar energy generator was installed in a hospital. The solar generator has a maximum power of 150 W; together with a battery it can deliver the energy for a minimum 5 hr of emergency illumination.

  11. SHARP User Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Y. Q.; Shemon, E. R.; Thomas, J. W.

    SHARP is an advanced modeling and simulation toolkit for the analysis of nuclear reactors. It is comprised of several components including physical modeling tools, tools to integrate the physics codes for multi-physics analyses, and a set of tools to couple the codes within the MOAB framework. Physics modules currently include the neutronics code PROTEUS, the thermal-hydraulics code Nek5000, and the structural mechanics code Diablo. This manual focuses on performing multi-physics calculations with the SHARP ToolKit. Manuals for the three individual physics modules are available with the SHARP distribution to help the user to either carry out the primary multi-physics calculationmore » with basic knowledge or perform further advanced development with in-depth knowledge of these codes. This manual provides step-by-step instructions on employing SHARP, including how to download and install the code, how to build the drivers for a test case, how to perform a calculation and how to visualize the results. Since SHARP has some specific library and environment dependencies, it is highly recommended that the user read this manual prior to installing SHARP. Verification tests cases are included to check proper installation of each module. It is suggested that the new user should first follow the step-by-step instructions provided for a test problem in this manual to understand the basic procedure of using SHARP before using SHARP for his/her own analysis. Both reference output and scripts are provided along with the test cases in order to verify correct installation and execution of the SHARP package. At the end of this manual, detailed instructions are provided on how to create a new test case so that user can perform novel multi-physics calculations with SHARP. Frequently asked questions are listed at the end of this manual to help the user to troubleshoot issues.« less

  12. Economic Analysis Case Studies of Battery Energy Storage with SAM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DiOrio, Nicholas; Dobos, Aron; Janzou, Steven

    2015-11-01

    Interest in energy storage has continued to increase as states like California have introduced mandates and subsidies to spur adoption. This energy storage includes customer sited behind-the-meter storage coupled with photovoltaics (PV). This paper presents case study results from California and Tennessee, which were performed to assess the economic benefit of customer-installed systems. Different dispatch strategies, including manual scheduling and automated peak-shaving were explored to determine ideal ways to use the storage system to increase the system value and mitigate demand charges. Incentives, complex electric tariffs, and site specific load and PV data were used to perform detailed analysis. Themore » analysis was performed using the free, publically available System Advisor Model (SAM) tool. We find that installation of photovoltaics with a lithium-ion battery system priced at $300/kWh in Los Angeles under a high demand charge utility rate structure and dispatched using perfect day-ahead forecasting yields a positive net-present value, while all other scenarios cost the customer more than the savings accrued. Different dispatch strategies, including manual scheduling and automated peak-shaving were explored to determine ideal ways to use the storage system to increase the system value and mitigate demand charges. Incentives, complex electric tariffs, and site specific load and PV data were used to perform detailed analysis. The analysis was performed using the free, publically available System Advisor Model (SAM) tool. We find that installation of photovoltaics with a lithium-ion battery system priced at $300/kWh in Los Angeles under a high demand charge utility rate structure and dispatched using perfect day-ahead forecasting yields a positive net-present value, while all other scenarios cost the customer more than the savings accrued.« less

  13. Smart home in a box: usability study for a large scale self-installation of smart home technologies.

    PubMed

    Hu, Yang; Tilke, Dominique; Adams, Taylor; Crandall, Aaron S; Cook, Diane J; Schmitter-Edgecombe, Maureen

    2016-07-01

    This study evaluates the ability of users to self-install a smart home in a box (SHiB) intended for use by a senior population. SHiB is a ubiquitous system, developed by the Washington State University Center for Advanced Studies in Adaptive Systems (CASAS). Participants involved in this study are from the greater Palouse region of Washington State, and there are 13 participants in the study with an average age of 69.23. The SHiB package, which included several different types of components to collect and transmit sensor data, was given to participants to self-install. After installation of the SHiB, the participants were visited by researchers for a check of the installation. The researchers evaluated how well the sensors were installed and asked the resident questions about the installation process to help improve the SHiB design. The results indicate strengths and weaknesses of the SHiB design. Indoor motion tracking sensors are installed with high success rate, low installation success rate was found for door sensors and setting up the Internet server.

  14. Smart home in a box: usability study for a large scale self-installation of smart home technologies

    PubMed Central

    Hu, Yang; Tilke, Dominique; Adams, Taylor; Crandall, Aaron S.; Schmitter-Edgecombe, Maureen

    2017-01-01

    This study evaluates the ability of users to self-install a smart home in a box (SHiB) intended for use by a senior population. SHiB is a ubiquitous system, developed by the Washington State University Center for Advanced Studies in Adaptive Systems (CASAS). Participants involved in this study are from the greater Palouse region of Washington State, and there are 13 participants in the study with an average age of 69.23. The SHiB package, which included several different types of components to collect and transmit sensor data, was given to participants to self-install. After installation of the SHiB, the participants were visited by researchers for a check of the installation. The researchers evaluated how well the sensors were installed and asked the resident questions about the installation process to help improve the SHiB design. The results indicate strengths and weaknesses of the SHiB design. Indoor motion tracking sensors are installed with high success rate, low installation success rate was found for door sensors and setting up the Internet server. PMID:28936390

  15. Safety analysis in test facility design

    NASA Astrophysics Data System (ADS)

    Valk, A.; Jonker, R. J.

    1990-09-01

    The application of safety analysis techniques as developed in, for example nuclear and petrochemical industry, can be very beneficial in coping with the increasing complexity of modern test facility installations and their operations. To illustrate the various techniques available and their phasing in a project, an overview of the most commonly used techniques is presented. Two case studies are described: the hazard and operability study techniques and safety zoning in relation to the possible presence of asphyxiating atmospheres.

  16. Risk Factors for Intracardiac Thrombosis in the Right Atrium and Superior Vena Cava in Critically Ill Neonates who Required the Installation of a Central Venous Catheter.

    PubMed

    Ulloa-Ricardez, Alfredo; Romero-Espinoza, Lizett; Estrada-Loza, María de Jesús; González-Cabello, Héctor Jaime; Núñez-Enríquez, Juan Carlos

    2016-08-01

    Central venous catheter (CVC) installation is essential for the treatment of critically ill neonates; however, it is associated with the development of neonatal intracardiac thrombosis, which is a complication that is associated with a poor prognosis. We aimed to identify specific risk factors for the development of intracardiac thrombosis in the right atrium (RA) and superior vena cava (SVC) related to the use of CVC in critically ill neonates. A case-control study was conducted at the tertiary referral neonatal intensive care unit of the Pediatric Hospital Siglo XXI in Mexico City, Mexico from 2008 to 2013. The included cases (n = 43) were de novo patients with intracardiac thrombosis in the RA and SVC diagnosed by echocardiography. The controls (n = 43) were neonates without intracardiac thrombosis or thrombosis at other sites. A logistic regression analysis was conducted, and odds ratios (ORs) and 95% confidence intervals (95% CIs) were calculated. The independent risk factors for intracardiac thrombosis in the RA and SVC were the surgical cut-down insertion technique (OR = 2.98; 95% CI: 1.18-9.10), a maternal history of gestational diabetes/diabetes mellitus (OR = 10.64; 95% CI: 1.13-121.41), Staphylococcus epidermidis infection (OR = 7.09; 95% CI: 1.09-45.92), and CVC placement in the SVC (OR = 5.77; 95% CI: 1.10-30.18). This study allowed us to identify several contributing factors to the development of intracardiac thrombosis in the RA and SVC related to the installation of a CVC in a subgroup of critically ill neonates. Multicenter and well-designed studies with a larger number of patients could help validate our findings and/or identify other risk factors that were not identified in the present study. Copyright © 2015. Published by Elsevier B.V.

  17. The Zond Victory Garden Phase 4 windfarm: A planning, installation, and performance case study. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chapman, J.

    1994-07-01

    This is one of a series of reports that document the steps taken to plan and install a utility-scale windfarm and follow its energy production performance. The reports are intended to help utility planners and others better understand the issues involved in installing and operating a windfarm. This report describes the Zond Victory Garden Phase IV (VGIV) windfarm in the Tehachapi mountain region, 100 miles north of Los Angeles. The Victory Garden series of windfarms were planned and installed and are operated by Zond Systems, Inc. of Tehachapi, California. The VGIV installation, which became operational in stages from January throughmore » June 1990, consists of 98 Vestas V27--225 wind turbines. The total rated capacity is 22 MW with a projected annual average net energy production of 54.3 million kWh/yr, equivalent to an annual capacity factor of 0.28. This energy projection, based on extensive wind resource measurements and an average wind turbine availability of 97%, includes the effects of a number of operational loss factors. The report includes descriptions of the windfarm layout, the wind turbine component, and the electrical layout. Particular attention is paid to one of the most important issues in implementing a windfarm, namely, the wind resource assessment and its use in projecting and updating the expected annual-average energy production of the facility. Also included are details of the planning, construction, and commissioning of the windfarm along with a description of the operations and maintenance procedures employed.« less

  18. Building America Case Study: Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test, Minneapolis, Minnesota

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    High performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiencymore » water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.« less

  19. TWO-LAYER MODEL FOR PULL-OUT BEHAVIOR OF POST-INSTALLED ANCHOR

    NASA Astrophysics Data System (ADS)

    Saleem, Muhammad; Tsubaki, Tatsuya

    A new two-layer anchor-infill assembly structure for the post-installed anchor is introduced with the analytical model to simulate its pull-out deformational response. The post-installed anchor is such that used in strengthening techniques for reinforced concrete structures. The properties of the infill material used for post-installed anchor are characterized by nonlinear interfaces. Because of the mechanical properties of the infill layer the existing pull-out model of deformed bars is not applicable in this case. Interfacial de-bonding is examined using energy criterion and strength criterion. The effect of the interface properties such as stiffness and strength on the pull-out behavior of a post-installed anchor is investigated. Using sensitivity analysis, the effect of these parameters on load-displacement curve, shear stress distribution, de-bonded length and damage to the surrounding concrete is clarified. Then, the optimum combination of these parameters is presented. It is confirmed that the elastic modulus of infill should be large to reduce the pull-out displacement and the increase of the shear strength of infill makes the pull-out load larger.

  20. 30 CFR 250.1722 - If I install a subsea protective device, what requirements must I meet?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... protective covering, the casing stub or mud line suspension equipment, or the trawl, and a discussion of any... subsea wellheads, casing stubs, mud line suspensions, or other obstructions in water depths less than 300... reveals that a casing stub or mud line suspension is no longer properly protected, or if the trawl does...

  1. CernVM WebAPI - Controlling Virtual Machines from the Web

    NASA Astrophysics Data System (ADS)

    Charalampidis, I.; Berzano, D.; Blomer, J.; Buncic, P.; Ganis, G.; Meusel, R.; Segal, B.

    2015-12-01

    Lately, there is a trend in scientific projects to look for computing resources in the volunteering community. In addition, to reduce the development effort required to port the scientific software stack to all the known platforms, the use of Virtual Machines (VMs)u is becoming increasingly popular. Unfortunately their use further complicates the software installation and operation, restricting the volunteer audience to sufficiently expert people. CernVM WebAPI is a software solution addressing this specific case in a way that opens wide new application opportunities. It offers a very simple API for setting-up, controlling and interfacing with a VM instance in the users computer, while in the same time offloading the user from all the burden of downloading, installing and configuring the hypervisor. WebAPI comes with a lightweight javascript library that guides the user through the application installation process. Malicious usage is prohibited by offering a per-domain PKI validation mechanism. In this contribution we will overview this new technology, discuss its security features and examine some test cases where it is already in use.

  2. Energy Policy Case Study - Texas: Wind, Markets, and Grid Modernization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Orrell, Alice C.; Homer, Juliet S.; Bender, Sadie R.

    This document presents a case study of energy policies in Texas related to power system transformation, renewable energy and distributed energy resources (DERs). Texas has experienced a dramatic increase in installed wind capacity, from 116 MW in 2000 to over 15,000 MW in 2015. This achievement was enabled by the designation of Competitive Renewable Energy Zones (CREZs) and new transmission lines that transmit wind to load centers. This report highlights nascent efforts to include DERs in the ERCOT market. As costs decline and adoption rates increase, ERCOT expects distributed generation to have an increasing effect on grid operations, while bringingmore » potentially valuable new resources to the wholesale markets.« less

  3. Natural Flow Air Cooled Photovoltaics

    NASA Astrophysics Data System (ADS)

    Tanagnostopoulos, Y.; Themelis, P.

    2010-01-01

    Our experimental study aims to investigate the improvement in the electrical performance of a photovoltaic installation on buildings through cooling of the photovoltaic panels with natural air flow. Our experimental study aims to investigate the improvement in the electrical performance of a photovoltaic installation on buildings through cooling of the photovoltaic panels with natural air flow. We performed experiments using a prototype based on three silicon photovoltaic modules placed in series to simulate a typical sloping building roof with photovoltaic installation. In this system the air flows through a channel on the rear side of PV panels. The potential for increasing the heat exchange from the photovoltaic panel to the circulating air by the addition of a thin metal sheet (TMS) in the middle of air channel or metal fins (FIN) along the air duct was examined. The operation of the device was studied with the air duct closed tightly to avoid air circulation (CLOSED) and the air duct open (REF), with the thin metal sheet (TMS) and with metal fins (FIN). In each case the experiments were performed under sunlight and the operating parameters of the experimental device determining the electrical and thermal performance of the system were observed and recorded during a whole day and for several days. We collected the data and form PV panels from the comparative diagrams of the experimental results regarding the temperature of solar cells, the electrical efficiency of the installation, the temperature of the back wall of the air duct and the temperature difference in the entrance and exit of the air duct. The comparative results from the measurements determine the improvement in electrical performance of the photovoltaic cells because of the reduction of their temperature, which is achieved by the naturally circulating air.

  4. Fast Deployment on the Cloud of Integrated Postgres, API and a Jupyter Notebook for Geospatial Collaboration

    NASA Astrophysics Data System (ADS)

    Fatland, R.; Tan, A.; Arendt, A. A.

    2016-12-01

    We describe a Python-based implementation of a PostgreSQL database accessed through an Application Programming Interface (API) hosted on the Amazon Web Services public cloud. The data is geospatial and concerns hydrological model results in the glaciated catchment basins of southcentral and southeast Alaska. This implementation, however, is intended to be generalized to other forms of geophysical data, particularly data that is intended to be shared across a collaborative team or publicly. An example (moderate-size) dataset is provided together with the code base and a complete installation tutorial on GitHub. An enthusiastic scientist with some familiarity with software installation can replicate the example system in two hours. This installation includes database, API, a test Client and a supporting Jupyter Notebook, specifically oriented towards Python 3 and markup text to comprise an executable paper. The installation 'on the cloud' often engenders discussion and consideration of cloud cost and safety. By treating the process as somewhat "cookbook" we hope to first demonstrate the feasibility of the proposition. A discussion of cost and data security is provided in this presentation and in the accompanying tutorial/documentation. This geospatial data system case study is part of a larger effort at the University of Washington to enable research teams to take advantage of the public cloud to meet challenges in data management and analysis.

  5. Case study of a central-station grid-intertie photovoltaic system with V-trough concentration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Freilich, J.; Gordon, J.M.

    1991-01-01

    This presentation is a cast study of an installed, central-station (no storage), utility-intertie photovoltaic (PV) system in Sede Boqer, Israel (latitude 30.9{degree}N). The nominally 12 kW peak PV system is comprised of 189 polycrystalline silicon modules mounted on inexpensive, one-axis north-south horizontal trackers with V-trough mirrors for optical boost. The power conditioning unit operates at a fixed voltage rather than at maximum power point (MPP). The primary task in analyzing the installed system was to investigate the cause of measured power output significantly below the design predictions of the installers, and to recommend system design modifications. Subsequent tasks included themore » quantitative assessment of fixed-voltage operation and of the energetic value of V-trough concentration and one-axis tracking for this system. Sample results show: (1) fixed-voltage operation at the best fixed voltage (BFV) can achieve around 96% of the yearly energy of MPP operation; (2) the sensitivity of the yearly energy delivery to the selection of fixed voltage and its marked asymmetry about the BFV; (3) the influences of inverter current constraints on yearly energy delivery and BFV; and (4) how the separate effects of tracking and optical concentration increase yearly energy delivery.« less

  6. A Case Study on Engineering Failure Analysis of Link Chain

    PubMed Central

    Lee, Seong-Beom; Lee, Hong-Chul

    2010-01-01

    Objectives The objective of this study was to investigate the effect of chain installation condition on stress distribution that could eventually cause disastrous failure from sudden deformation and geometric rupture. Methods Fractographic method used for the failed chain indicates that over-stress was considered as the root cause of failure. 3D modeling and finite element analysis for the chain, used in a crane hook, were performed with a three-dimensional interactive application program, CATIA, commercial finite element analysis and computational fluid dynamic software, ANSYS. Results The results showed that the state of stress was changed depending on the initial position of the chain that was installed in the hook. Especially, the magnitude of the stress was strongly affected by the bending forces, which are 2.5 times greater (under the simulation condition currently investigated) than that from the plain tensile load. Also, it was noted that the change of load state is strongly related to the failure of parts. The chain can hold an ultimate load of about 8 tons with only the tensile load acting on it. Conclusion The conclusions of this research clearly showed that a reduction of the loss from similar incidents can be achieved when an operator properly handles the installation of the chain. PMID:22953162

  7. 47 CFR 101.131 - Transmitter construction and installation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... by the licensee. (b) In any case where the maximum modulating frequency of a transmitter is prescribed by the Commission, the transmitter must be equipped with a low-pass or band-pass modulation filter of suitable performance characteristics. In those cases where a modulation limiter is employed, the...

  8. One Family's Journey: Medical Home and the Network of Supports It Offers Children and Youth with Special Healthcare Needs--Medical Homes in Hospital Systems. Part Six

    ERIC Educational Resources Information Center

    Macdonald, Sarah; Hoffman, Alisa; Hagenbach, Tracy; Rusert, Julia

    2008-01-01

    In this 12 installment Medical Home series, "Exceptional Parent" presents a case study about the American Academy of Pediatrics' Medical Home Initiative. A "Medical Home" is not a building but an approach to providing healthcare services to children with special healthcare needs. This sixth part of the Medical Home series describes the experiences…

  9. One Family's Journey: Medical Home and the Network of Supports It Offers Children and Youth with Special Health Care Needs--Parent Partners

    ERIC Educational Resources Information Center

    Townsend, Sabra; Pola-Money, Gina; Gatto, Molly

    2007-01-01

    In this 12 installment Medical Home series, "EP" will present a case study about the American Academy of Pediatrics' Medical Home Initiative. A "Medical Home" is not a building. It is an approach to providing healthcare services to children with special healthcare needs. This article presents Part 3 in the series as readers learn more about Amita…

  10. Campus Energy Approach, REopt Overview, and Solar for Universities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elgqvist, Emma M; Van Geet, Otto D

    2017-10-19

    This presentation gives an overview of the climate neutral research campus framework for reducing energy use and meeting net zero electricity on research campuses. It gives an overview of REopt and the REopt Lite web tool, which can be used to evaluate cost optimal sizes of behind the meter PV and storage. It includes solar PV installation trends at universities and case studies for projects implemented on university campuses.

  11. The SmartOR: a distributed sensor network to improve operating room efficiency.

    PubMed

    Huang, Albert Y; Joerger, Guillaume; Fikfak, Vid; Salmon, Remi; Dunkin, Brian J; Bass, Barbara L; Garbey, Marc

    2017-09-01

    Despite the significant expense of OR time, best practice achieves only 70% efficiency. Compounding this problem is a lack of real-time data. Most current OR utilization programs require manual data entry. Automated systems require installation and maintenance of expensive tracking hardware throughout the institution. This study developed an inexpensive, automated OR utilization system and analyzed data from multiple operating rooms. OR activity was deconstructed into four room states. A sensor network was then developed to automatically capture these states using only three sensors, a local wireless network, and a data capture computer. Two systems were then installed into two ORs, recordings captured 24/7. The SmartOR recorded the following events: any room activity, patient entry/exit time, anesthesia time, laparoscopy time, room turnover time, and time of preoperative patient identification by the surgeon. From November 2014 to December 2015, data on 1003 cases were collected. The mean turnover time was 36 min, and 38% of cases met the institutional goal of ≤30 min. Data analysis also identified outlier cases (>1 SD from mean) in the domains of time from patient entry into the OR to intubation (11% of cases) and time from extubation to patient exiting the OR (11% of cases). Time from surgeon identification of patient to scheduled procedure start time was 11 min (institution bylaws require 20 min before scheduled start time), yet OR teams required 22 min on average to bring a patient into the room after surgeon identification. The SmartOR automatically and reliably captures data on OR room state and, in real time, identifies outlier cases that may be examined closer to improve efficiency. As no manual entry is required, the data are indisputable and allow OR teams to maintain a patient-centric focus.

  12. KENNEDY SPACE CENTER, FLA. - Armando Oliu, Final Inspection Team lead for the Shuttle program, speaks to reporters about the aid the Image Analysis Lab is giving the FBI in a kidnapping case. Oliu oversees the image lab that is using an advanced SGI® TP9500 data management system to review the tape of the kidnapping in progress in Sarasota, Fla. KSC installed the new $3.2 million system in preparation for Return to Flight of the Space Shuttle fleet. The lab is studying the Sarasota kidnapping video to provide any new information possible to law enforcement officers. KSC is joining NASA’s Marshall Space Flight Center in Alabama in reviewing the tape.

    NASA Image and Video Library

    2004-02-04

    KENNEDY SPACE CENTER, FLA. - Armando Oliu, Final Inspection Team lead for the Shuttle program, speaks to reporters about the aid the Image Analysis Lab is giving the FBI in a kidnapping case. Oliu oversees the image lab that is using an advanced SGI® TP9500 data management system to review the tape of the kidnapping in progress in Sarasota, Fla. KSC installed the new $3.2 million system in preparation for Return to Flight of the Space Shuttle fleet. The lab is studying the Sarasota kidnapping video to provide any new information possible to law enforcement officers. KSC is joining NASA’s Marshall Space Flight Center in Alabama in reviewing the tape.

  13. KENNEDY SPACE CENTER, FLA. - Reporters are eager to hear from Armando Oliu about the aid the Image Analysis Lab is giving the FBI in a kidnapping case. Oliu, Final Inspection Team lead for the Shuttle program, oversees the lab that is using an advanced SGI® TP9500 data management system to review the tape of the kidnapping in progress in Sarasota, Fla. KSC installed the new $3.2 million system in preparation for Return to Flight of the Space Shuttle fleet. The lab is studying the Sarasota kidnapping video to provide any new information possible to law enforcement officers. KSC is joining NASA’s Marshall Space Flight Center in Alabama in reviewing the tape.

    NASA Image and Video Library

    2004-02-04

    KENNEDY SPACE CENTER, FLA. - Reporters are eager to hear from Armando Oliu about the aid the Image Analysis Lab is giving the FBI in a kidnapping case. Oliu, Final Inspection Team lead for the Shuttle program, oversees the lab that is using an advanced SGI® TP9500 data management system to review the tape of the kidnapping in progress in Sarasota, Fla. KSC installed the new $3.2 million system in preparation for Return to Flight of the Space Shuttle fleet. The lab is studying the Sarasota kidnapping video to provide any new information possible to law enforcement officers. KSC is joining NASA’s Marshall Space Flight Center in Alabama in reviewing the tape.

  14. Quieting Weinberg 5C: a case study in hospital noise control.

    PubMed

    MacLeod, Mark; Dunn, Jeffrey; Busch-Vishniac, Ilene J; West, James E; Reedy, Anita

    2007-06-01

    Weinberg 5C of Johns Hopkins Hospital is a very noisy hematological cancer unit in a relatively new building of a large medical campus. Because of the requirements for dealing with immuno-suppressed patients, options for introducing sound absorbing materials are limited. In this article, a case study of noise control in a hospital, the sound environment in the unit before treatment is described, the chosen noise control approach of adding custom-made sound absorbing panels is presented, and the impact of the noise control installation is discussed. The treatment of Weinberg 5C involved creating sound absorbing panels of 2-in.-thick fiberglass wrapped in an anti-bacterial fabric. Wallpaper paste was used to hold the fabric to the backing of the fiberglass. Installation of these panels on the ceiling and high on corridor walls had a dramatic effect. The noise on the unit (as measured by the equivalent sound pressure level) was immediately reduced by 5 dB(A) and the reverberation time dropped by a factor of over 2. Further, this drop in background noise and reverberation time understates the dramatic impact of the change. Surveys of staff and patients before and after the treatment indicated a change from viewing the unit as very noisy to a view of the unit as relatively quiet.

  15. Testing and Performance Verification of a High Bypass Ratio Turbofan Rotor in an Internal Flow Component Test Facility

    NASA Technical Reports Server (NTRS)

    VanZante, Dale E.; Podboy, Gary G.; Miller, Christopher J.; Thorp, Scott A.

    2009-01-01

    A 1/5 scale model rotor representative of a current technology, high bypass ratio, turbofan engine was installed and tested in the W8 single-stage, high-speed, compressor test facility at NASA Glenn Research Center (GRC). The same fan rotor was tested previously in the GRC 9x15 Low Speed Wind Tunnel as a fan module consisting of the rotor and outlet guide vanes mounted in a flight-like nacelle. The W8 test verified that the aerodynamic performance and detailed flow field of the rotor as installed in W8 were representative of the wind tunnel fan module installation. Modifications to W8 were necessary to ensure that this internal flow facility would have a flow field at the test package that is representative of flow conditions in the wind tunnel installation. Inlet flow conditioning was designed and installed in W8 to lower the fan face turbulence intensity to less than 1.0 percent in order to better match the wind tunnel operating environment. Also, inlet bleed was added to thin the casing boundary layer to be more representative of a flight nacelle boundary layer. On the 100 percent speed operating line the fan pressure rise and mass flow rate agreed with the wind tunnel data to within 1 percent. Detailed hot film surveys of the inlet flow, inlet boundary layer and fan exit flow were compared to results from the wind tunnel. The effect of inlet casing boundary layer thickness on fan performance was quantified. Challenges and lessons learned from testing this high flow, low static pressure rise fan in an internal flow facility are discussed.

  16. Using Advanced Tensiometers to Monitor Temporal Variations in Pore Pressure

    NASA Astrophysics Data System (ADS)

    Nichols, R. L.; Young, M. H.; Dixon, K. L.; Rossabi, J.; Hyde, W. K.; Holmes-Burns, H.

    2002-12-01

    The Savannah River Site has installed a comprehensive vadose zone monitoring system (VZMS) at it's low level radioactive waste disposal facility to collect the necessary information to calculate contaminant flux. The VZMS includes water content reflectometers, suction lysimeters, advanced tensiometers (ATs), water flux meters, access ports for neutron probes, and a tipping bucket rain gauge. Forty one ATs were installed from 1999 to 2001 at depths ranging from 2 to 60 feet and have been operated continuously. The installation depths were based on a hydrostatigraphic model developed from core logs, cone penetrometer logs, moisture content profiles, water retention curves model that were obtained during the phased installation of the VZMS. An AT consists of a porous cup installed at a prescribed depth with casing back to the surface and a pressure transducer that is lowered into the casing and connects with the porous cup. The pressure transducer transmits it's signal to a datalogger where the data is stored for future retrieval using a cellular phone communications package. Results from the 2 year operating period show that the AT calibrations are stable and t ATs are capable of extended monitoring of pore pressures in the 0 to 300 cm H2 O range. The ATs had sufficient resolution to detect the naturally occurring fluctuations in pore pressure (1 to 100 cm H2 O over 1 to 72 hours) that resulted from infiltration events at the site. The stable performance of the ATs combined with their ability to detect naturally occurring fluctuations in pore pressure make the ATs a useful tool in measuring temporal pore pressure variations for use in calibrating numerical models of fluid flow in variably saturated porous media.

  17. Assessment of Augmented Electronic Fuel Controls for Modular Engine Diagnostics and Condition Monitoring

    DTIC Science & Technology

    1978-12-01

    not retumn it to the originator. Unclassified READ INSTRUCTIONSJ EPORT DOCUMENTATION PAGE BEFORE COMPLETING FORMJ. GOVT ACCESSr - ECIPIENT’S CATALOG...responsible for low engine performance of an installed engine. In the case of the T700, a study was completed in Nov. 197 7 which def8 nod an analytical...ECM study has been completed . T" e results of the various systems considered areo presented below. &sateim A - Az exponsive system foaturing in- X ~(X

  18. Tentative Study on Performance of Darriues-Type Hydroturbine Operated in Small Open Water Channel

    NASA Astrophysics Data System (ADS)

    Matsushita, D.; Moriyama, R.; Nakashima, K.; Watanabe, S.; Okuma, K.; Furukawa, A.

    2014-03-01

    The development of small hydropower is one of the realistic and preferable utilizations of renewable energy, but the extra-low head hydropower less than 2 m is almost undeveloped yet for some reasons. The authors have developed several types of Darrieus-type hydro-turbine system, and among them, the Darrieus-turbine with a wear and a nozzle installed upstream of turbine is so far in success to obtain more output power, i.e. more shaft torque, by gathering all water into the turbine. However, there can several cases exist, in which installing the wear covering all the flow channel width is unrealistic. Then, in the present study, the hydraulic performances of Darrieus-type hydro-turbine with the inlet nozzle is investigated, putting alone in a small open channel without upstream wear. In the experiment, the five-bladed Darrieus-type runner with the pitch-circle diameter of 300 mm and the blade span of 300 mm is vertically installed in the open channel with the width of 1,200 mm. The effectiveness of the shape of the inlet nozzle is also examined using two types of two-dimensional symmetric nozzle, the straight line nozzle (SL nozzle) with the converging angle of 45 degrees and the half diameter curved nozzle (HD nozzle) whose radius is a half diameter of runner pitch circle. Inlet and outlet nozzle widths are in common for the both nozzles, which are 540 mm and 240 mm respectively. All the experiments are carried out under the conditions with constant flow rate and downstream water level, and performances are evaluated by measured output torque and the measured head difference between the water levels upstream and downstream of the turbine. As a result, it is found that the output power is remarkably increased by installing the inlet nozzle, and the turbine with SL nozzle produces larger power than that with HD nozzle. However, the peak efficiency is deteriorated in both cases. The speed ratio defined by the rotor speed divided by the downstream water velocity at the peak efficiency is larger in both cases with the inlet nozzle, partly due to the increase of inflow velocity into the turbine. In order to understand the cause of the differences of power, i.e. torque characteristics of the turbine with SL and HD nozzles, twodimensional CFD simulation is carried out. It is found that the instantaneous torque variation is important for the overall turbine performances, indicating the possibility of further performance improvement through the optimization of nozzle geometry.

  19. Development of a pin-post insulator with built-in metal oxide varistors for distribution lines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fujiwara, N.; Yoneyama, T.; Hamada, Y.

    1996-04-01

    A 6.6 kV pin-post insulator, incorporating ZnO varistors, has been developed in order to reduce line faults caused by direct lighting strikes, thereby reducing and simplifying maintenance work on distribution systems. The developed insulators are interchangeable with conventional pin insulators and can withstand internal fault currents twice upon their failures. The simulated results regarding the response of the developed insulators to direct lightning strikes on an overhead ground wire agreed well with the experimental results. Simulation studies also revealed that installing the developed insulators on every two poles reduces the line-fault rate of present distribution lines in case of directmore » lightning strikes by 33%, while installing them on every pole reduces the rate by 97.5% or about 1/40 of the original value.« less

  20. How can sludge dewatering devices be assessed? Development of a new DSS and its application to real case studies.

    PubMed

    Bertanza, Giorgio; Papa, Matteo; Canato, Matteo; Collivignarelli, Maria Cristina; Pedrazzani, Roberta

    2014-05-01

    A key issue in biological Waste Water Treatment Plants (WWTPs) operation is represented by the sludge management. Mechanical dewatering is a crucial stage for sludge volume reduction; though, being a costly operation, its optimization is required. We developed an original experimental methodology to evaluate the technical (dewatering efficiency) and financial (total treatment costs) performance of dewatering devices, which might be used as a DSS (Decision Support System) for WWTP managers. This tool was then applied to two real case studies for comparing, respectively, three industrial size centrifuges, and two different operation modes of the same machine (fixed installation vs. outsourcing service). In both the cases, the best option was identified, based jointly on economic and (site-specific) technical evaluations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. The Evolving Market Structure of the U.S. Residential Solar PV Installation Industry, 2000-2016

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    OShaughnessy, Eric J.

    This study uses data on over 900,000 solar PV installations to summarize the evolving market structure of the U.S. residential solar PV installation industry. Over 8,000 companies have installed residential PV systems in the United States. The vast majority of these installers are small local companies. At the same time, a subset of national-scale high-volume PV installation companies hold high market shares. This study examines the factors behind these trends in market concentration, including the role of customer financing options.

  2. Baseline studies to select the most sound and sensitive sites to install continuous monitoring per sismo-geochemical networks. The case history of the Norcia-Amatrice-Spoleto seismic sequences (2016-2017)

    NASA Astrophysics Data System (ADS)

    Quattrocchi, F.; Gallo, F.

    2017-12-01

    The paper review methodologically and historically - in the frame of seismo-geochemical studies in Italy and abroad to select the most "sensitive" sites along active faults, mostly where structural geology is not able to discover "blind" faults or complex fault crossing systems, with maximum fluids-faults interaction. The paper is highlighting the "site specific" case histories and processes helping in networks design, gathered in occasion of strong-moderate earthquakes, gas-burst or groundwater evolution in geothermal-hydrocarbons field during EU projects (i.e., Geochemical Seismic Zonation, 3F-Faults-Fractures-Fluids Corinth). Some concepts are highlighted based on gather experimental data in 25 years: - if the network is in soil gas is necessary a preliminary study on groundwater too, to understand the sectors of shallow aquifers, as "buffer" bodies, more prone to be oversaturated by geogas from depth; a preliminary grid should consider both the CO2-CH4-Rn fluxes, all gas concentrations and isotopes analyses (TDIC, CH4 CO2 , rare gas) case by case described here, mostly where the regional faults are crossing each other and where a carrier gas is acting i.e., CO2. It is very un-correct to install mono-parametric stations, i.e. only Radon to understand the real WRI processes. - if the network is in groundwater is very important a preliminary study before, during and after seismic sequences, to realize where the maximum anomalies (i.e., anomalous animal behavior, temperature increasing, geochemical anomalies, new gas relase) are and will be envisaged, as found for the Umbria-Marche border (the Colfiorito 1997-1998 and the 2016-2017 Norcia-Amatrice seismic sequences), where a deep pore-pressure dominated situation could be constrained by seismo-geochemistry, along "still silent" close fault segments too. if the network is in groundwater is very important a geochemical multidisciplinary approach to constrain the segment length and relative maximum magnitude.

  3. Role of water-saving devices in reducing urban water consumption in the mega-city of Tehran, case study: a residential complex.

    PubMed

    Bidhendi, Gholamreza Nabi; Nasrabadi, Touraj; Vaghefi, Hamid Reza Sharif; Hoveidi, Hassan; Jafari, Hamid Reza

    2008-04-01

    Iran is one of 27 countries that are likely to face increasing water shortage crises between now and 2025 unless action is taken to reduce currently high-per-capita urban water consumption. Accordingly, consumption control in the mega-city of Tehran will be an invaluable achievement. A study of Tehran water consumers has determined that household consumers are responsible for 70 percent of the total consumption. Keeping that figure in mind, the authors set out to assess rates of consumption by water fixtures, with an emphasis on household users, and to examine the effects of installing subcounters and reducers. They selected an apartment complex in which it was possible to install water subcounters for each unit. The first step was to evaluate resident attitudes. Block 3, which had 10 units, was selected to cooperate with the project. The second step was to install counters for all 10 units to determine consumption by different fixtures. (The counters were installed in kitchens, in bathrooms, on toilets, on washing machines, and on flash tanks). In the next step, data entry forms for fixture consumption were completed for a period of 10 days. Then single-handle faucets and reducers were installed, and the outcomes were logged for a period of 10 days. Counter readings were performed by the volunteer residents or by educated personnel every 24 hours, and the total volume of inside consumption was compared with the consumption registered by a base counter placed outside each unit. In the course of the project, the consumption per capita was calculated every 24 hours to yield a real and unbiased model that is applicable to city of Tehran. The results showed a total reduction in water consumption of about 20 percent. Thus, with suitable planning and application of cultural and technical methods, it is possible to optimize consumption in Tehran in the near future.

  4. Development of a methodology for strategic environmental assessment: application to the assessment of golf course installation policy in Taiwan.

    PubMed

    Chen, Ching-Ho; Wu, Ray-Shyan; Liu, Wei-Lin; Su, Wen-Ray; Chang, Yu-Min

    2009-01-01

    Some countries, including Taiwan, have adopted strategic environmental assessment (SEA) to assess and modify proposed policies, plans, and programs (PPPs) in the planning phase for pursuing sustainable development. However, there were only some sketchy steps focusing on policy assessment in the system of Taiwan. This study aims to develop a methodology for SEA in Taiwan to enhance the effectiveness associated with PPPs. The proposed methodology comprises an SEA procedure involving PPP management and assessment in various phases, a sustainable assessment framework, and an SEA management system. The SEA procedure is devised based on the theoretical considerations by systems thinking and the regulative requirements in Taiwan. The positive and negative impacts on ecology, society, and economy are simultaneously considered in the planning (including policy generation and evaluation), implementation, and control phases of the procedure. This study used the analytic hierarchy process, Delphi technique, and systems analysis to develop a sustainable assessment framework. An SEA management system was built based on geographic information system software to process spatial, attribute, and satellite image data during the assessment procedure. The proposed methodology was applied in the SEA of golf course installation policy in 2001 as a case study, which was the first SEA in Taiwan. Most of the 82 existing golf courses in 2001 were installed on slope lands and caused a serious ecological impact. Assessment results indicated that 15 future golf courses installed on marginal lands (including buffer zones, remedied lands, and wastelands) were acceptable because the comprehensive environmental (ecological, social, and economic) assessment value was better based on environmental characteristics and management regulations of Taiwan. The SEA procedure in the planning phase for this policy was completed but the implementation phase of this policy was not begun because the related legislation procedure could not be arranged due to a few senators' resistance. A self-review of the control phase was carried out in 2006 using this methodology. Installation permits for 12 courses on slope lands were terminated after 2001 and then 27 future courses could be installed on marginal lands. The assessment value of this policy using the data on ecological, social, and economic conditions from 2006 was higher than that using the data from 2001. The analytical results illustrate that the proposed methodology can be used to effectively and efficiently assist the related authorities for SEA.

  5. Feasibility study of strengthening the public-private partnership for tuberculosis case detection in Bandung City, Indonesia.

    PubMed

    Lestari, Bony Wiem; Arisanti, Nita; Siregar, Adiatma Y M; Sihaloho, Estro Dariatno; Budiman, Gelar; Hill, Philip C; Alisjahbana, Bachti; McAllister, Susan

    2017-08-14

    Private practitioner's (PPs) collaboration for detection, diagnosis and treatment of tuberculosis (TB) is recommended by the World Health Organization and encouraged by the Indonesian National TB control programme. TB case management by PPs, however, are mostly not in line with current guidelines. Therefore, we developed an intervention package for PPs comprising of TB training, implementation of a mobile phone application for notification of TB cases and a 6-month regular follow-up with PPs. This study aimed to evaluate the feasibility of the intervention package to increase TB case detection and notification rates among PPs in five community health centre areas in Bandung City, Indonesia. A total of 87 PPs were registered within the study area of whom 17 attended the training and 12 had the mobile phone application successfully installed. The remaining five PPs had phones that did not support the application. During the follow-up period, five PPs registered patients with TB symptoms and cases into the application. A total of 36 patients with TB symptoms were identified and 17 were confirmed TB positive.

  6. A study of pressure losses in residential air distribution systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abushakra, Bass; Walker, Iain S.; Sherman, Max H.

    2002-07-01

    An experimental study was conducted to evaluate the pressure drop characteristics of residential duct system components that are either not available or not thoroughly (sometimes incorrectly) described in existing duct design literature. The tests were designed to imitate cases normally found in typical residential and light commercial installations. The study included three different sizes of flexible ducts, under different compression configurations, splitter boxes, supply boots, and a fresh air intake hood. The experimental tests conformed to ASHRAE Standard 120P--''Methods of Testing to Determine Flow Resistance of HVAC Air Ducts and Fittings''. The flexible duct study covered compressibility and bending effectsmore » on the total pressure drop, and the results showed that the available published references tend to underestimate the effects of compression in flexible ducts that can increase pressure drops by up to a factor of nine. The supply boots were tested under different configurations including a setup where a flexible duct elbow connection was considered as an integral part of the supply boot. The supply boots results showed that diffusers can increase the pressure drop by up to a factor of two in exit fittings, and the installation configuration can increase the pressure drop by up to a factor of five. The results showed that it is crucial for designers and contractors to be aware of the compressibility effects of the flexible duct, and the installation of supply boots and diffusers.« less

  7. Towards Integrated Marmara Strong Motion Network

    NASA Astrophysics Data System (ADS)

    Durukal, E.; Erdik, M.; Safak, E.; Ansal, A.; Ozel, O.; Alcik, H.; Mert, A.; Kafadar, N.; Korkmaz, A.; Kurtulus, A.

    2009-04-01

    Istanbul has a 65% chance of having a magnitude 7 or above earthquake within the next 30 years. As part of the preparations for the future earthquake, strong motion networks have been installed in and around Istanbul. The Marmara Strong Motion Network, operated by the Department of Earthquake Engineering of Kandilli Observatory and Earthquake Research Institute, encompasses permanent systems outlined below. It is envisaged that the networks will be run by a single entity responsible for technical management and maintanence, as well as for data management, archiving and dissemination through dedicated web-based interfaces. • Istanbul Earthquake Rapid Response and Early Warning System - IERREWS (one hundred 18-bit accelerometers for rapid response; ten 24-bit accelerometers for early warning) • IGDAŞ Gas Shutoff Network (100 accelerometers to be installed in 2010 and integrated with IERREWS) • Structural Monitoring Arrays - Fatih Sultan Mehmet Suspension Bridge (1200m-long suspension bridge across the Bosphorus, five 3-component accelerometers + GPS sensors) - Hagia Sophia Array (1500-year-old historical edifice, 9 accelerometers) - Süleymaniye Mosque Array (450-year-old historical edifice,9 accelerometers) - Fatih Mosque Array (237-year-old historical edifice, 9 accelerometers) - Kanyon Building Array (high-rise office building, 5 accelerometers) - Isbank Tower Array (high-rise office building, 5 accelerometers) - ENRON Array (power generation facility, 4 acelerometers) - Mihrimah Sultan Mosque Array (450-year-old historical edifice,9 accelerometers + tiltmeters, to be installed in 2009) - Sultanahmet Mosque Array, (390-year-old historical edifice, 9 accelerometers + tiltmeters, to be installed in 2009) • Special Arrays - Atakoy Vertical Array (four 3-component accelerometers at 25, 50, 75, and 150 m depths) - Marmara Tube Tunnel (1400 m long submerged tunnel, 128 ch. accelerometric data, 24 ch. strain data, to be installed in 2010) - Air-Force Academy Array (72 ch. dense accelerometric array to be installed in 2010) - Gemlik Array (a dense basin array of 8 stations, to be installed in 2010) The objectives of these systems and networks are: (1) to produce rapid earthquake intensity, damage and loss assessment information after an earthquake (in the case of IERREWS), (2) to monitor conditions of structural systems, (3) to develop real-time data processing, analysis, and damage detection and location tools (in the case of structural networks) after an extreme event, (4) to assess spatial properties of strong ground motion and ground strain, and to characterise basin response (in the case of special arrays), (5) to investigate site response and wave propagation (in the case of vertical array). Ground motion data obtained from these strong motion networks have and are being used for investigations of attenuation, spatial variation (coherence), simulation benchmarking, source modeling, site response, seismic microzonation, system identification and structural model verification and structural health control. In addition to the systems and networks outlined above there are two temporary networks: KIMNET - a dense urban noise and microtremor network consisting of 50 broadband stations expected to be operational in mid 2009, and SOSEWIN - a 20-station, self-organizing structural integrated array at Ataköy in Istanbul.

  8. 16 CFR § 1406.2 - Background.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... BURNING APPLIANCES-NOTIFICATION OF PERFORMANCE AND TECHNICAL DATA § 1406.2 Background. (a) Fire data... burning appliances. Many of these cases involve improper installation of the appliances, especially where...

  9. RHIC Prefire Protection Masks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drees, A.; Biscardi, C.; Curcio, T.

    2015-01-07

    The protection of the RHIC experimental detectors from damage due to beam hitting close upstream elements in cases of abort kicker prefires requires some dedicated precautionary measures with two general options: to bring the beam close to a limiting aperture (i.e. the beam pipe wall), as far upstream of the detector components as possible or, alternatively, to bring a limiting aperture close to the circulating beam. During the FY 2014 RHIC Heavy Ion run the first option was chosen because of the limited time available for preparation before the start of the run. For future runs the second option, inmore » this case the installation of dual-sided movable masks, is preferred. The installation of the masks, one per ring, is planned before the start of the FY 2015 run.« less

  10. Possibility of heat recovery from gray water in residential building

    NASA Astrophysics Data System (ADS)

    Mazur, Aleksandra; Słyś, Daniel

    2017-12-01

    Recovery of waste heat from gray water can be an interesting alternative to other energy saving systems in a building, including alternative energy sources. Mainly, due to a number of advantages including independence from weather conditions, small investment outlay, lack of user support, or a slight interference with the installation system. The purpose of this article is to present the financial effectiveness of installations which provide hot, usable water to a detached house, using a Drain Water Heat Recovery (DWHR) system depending on the number of system users and the various combinations of bathing time in the shower, which has an influence on the daily warm water demand in each of the considered options. The economic analysis of the adopted installation variants is based on the Life Cycle Cost (LCC) method, which is characterized by the fact that it also includes the operating costs in addition to the capital expenditure during the entire analysis period. For each case, the necessary devices were selected and the cost of their installation was estimated.

  11. An evaluation of a risk-based environmental regulation in Brazil: Limitations to risk management of hazardous installations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Naime, Andre, E-mail: andre.naime.ibama@gmail.com

    The environmental regulation of hazardous projects with risk-based decision-making processes can lead to a deficient management of human exposure to technological hazards. Such an approach for regulation is criticized for simplifying the complexity of decisions involving the economic, social, and environmental aspects of the installation and operation of hazardous facilities in urban areas. Results of a Brazilian case study indicate that oil and gas transmission pipelines may represent a threat to diverse communities if the relationship between such linear projects and human populations is overlooked by regulatory bodies. Results also corroborate known challenges to the implementation of EIA processes andmore » outline limitations to an effective environmental and risk management. Two preliminary topics are discussed to strengthen similar regulatory practices. Firstly, an effective integration between social impact assessment and risk assessment in EIA processes to have a more comprehensive understanding of the social fabric. Secondly, the advancement of traditional management practices for hazardous installations to pursue a strong transition from assessment and evaluation to management and control and to promote an effective interaction between land-use planning and environmental regulation.« less

  12. Analysis of thermal characteristics of electrical wiring for load groups in cattle barns.

    PubMed

    Kim, Doo Hyun; Yoo, Sang-Ok; Kim, Sung Chul; Hwang, Dong Kyu

    2015-01-01

    The purpose of the current study is to analyze the thermal characteristics of electrical wirings depending on the number of operating load by connecting four types of electrical wirings that are selected by surveying the conditions for the electric fans, automatic waterers and halogen warm lamps that were installed in cattle barns in different years. The conditions of 64 cattle barns were surveyed and an experimental test was conducted at a cattle barn. The condition-survey covered inappropriate design, construction and misuse of electrical facility, including electrical wiring mostly used, and the mode of load current was evaluated. The survey showed that the mode of load current increased as the installation year of the fans, waterers and halogen lamps became older. Accordingly, the cattle barn manager needed to increase the capacity of the circuit breaker, which promoted the degradation of insulation of the electrical wires' sheath and increased possibility for electrical fires in the long-run. The test showed that the saturation temperature of the wire insulated sheath increased depending on the installation year of the load groups, in case of VCTFK and VFF electric wires, therefore, requiring their careful usage in the cattle barns.

  13. Analysis of thermal characteristics of electrical wiring for load groups in cattle barns

    PubMed Central

    KIM, Doo Hyun; YOO, Sang-Ok; KIM, Sung Chul; HWANG, Dong Kyu

    2015-01-01

    The purpose of the current study is to analyze the thermal characteristics of electrical wirings depending on the number of operating load by connecting four types of electrical wirings that are selected by surveying the conditions for the electric fans, automatic waterers and halogen warm lamps that were installed in cattle barns in different years. The conditions of 64 cattle barns were surveyed and an experimental test was conducted at a cattle barn. The condition-survey covered inappropriate design, construction and misuse of electrical facility, including electrical wiring mostly used, and the mode of load current was evaluated. The survey showed that the mode of load current increased as the installation year of the fans, waterers and halogen lamps became older. Accordingly, the cattle barn manager needed to increase the capacity of the circuit breaker, which promoted the degradation of insulation of the electrical wires’ sheath and increased possibility for electrical fires in the long-run. The test showed that the saturation temperature of the wire insulated sheath increased depending on the installation year of the load groups, in case of VCTFK and VFF electric wires, therefore, requiring their careful usage in the cattle barns. PMID:26118855

  14. Building America Case Study: Standard- Versus High-Velocity Air Distribution in High-Performance Townhomes, Denver, Colorado

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A. Poerschke, R. Beach, T. Begg

    IBACOS investigated the performance of a small-diameter high-velocity heat pump system compared to a conventional system in a new construction triplex townhouse. A ductless heat pump system also was installed for comparison, but the homebuyer backed out because of aesthetic concerns about that system. In total, two buildings, having identical solar orientation and comprised of six townhomes, were monitored for comfort and energy performance.

  15. Installation and assembly device and method of using

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kolsun, G.J.

    1995-12-31

    The present invention relates to an installation and assembly device and method for facilitating the fitup of mating components during blind or remote installation and assembly, especially where close fitup tolerances are involved. The present invention is particularly useful for the purpose of facilitating vertical and/or radial relative positioning of a pump impeller within a mating inlet nozzle during a blind assembly wherein actual fitup cannot be observed during installation. The information within identifies just one successful application of the installation and assembly alignment device for a pump. The device, however, is not solely limited to pump assembly but canmore » be used in other cases where fitup of a sleeve inside a mating bore is required under conditions of close tolerance during a blind or remote assembly. The device is likewise not limited to circular configurations but can be used for many other shapes or configurations. Any material that can be machined and hold reasonably close tolerances can be used for the device. Also, because the sleeve position is adjusted by set screws or bolts, the concentricity can be radially biased, if required, to achieve particular alignment conditions.« less

  16. Reeled pipelay cost reduction using workboat-based installation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoffman, J.G.; El Laithy, W.F.; Rothberg, R.H.

    1995-11-01

    Coiled ``tubing`` is a rapidly growing pipeline technology. because this technology is relatively new, cost can vary significantly depending on deployment strategies and installation techniques. Up until recently coiled pipe was used primarily by service companies for coiled tubing workovers. As the technology expanded the industry began using coiled tubing for other applications such as drilling, coring, logging, well cleanout operations and artificial lift. With the recent advent of larger sizes, three and one half inches, it was now possible to consider using coiled tubing as pipelines. The coiled pipe was proving to be a low cost, time saving, economicmore » alternative to conventional welded pipe for flowlines. Coiled pipe applications have been used in 4 to 100 feet of water in the Gulf of Mexico area and the installation techniques have varied significantly. Considerable engineering work has been done in preparation for GUPCO`s first dynamic lay installation for a subsea well tie-in on Ramadan 22. Subsequently GUPCO installed the worlds longest known coiled pipeline on SB 367. This paper will cover the significant findings of that engineering work and present actual field case histories on Egypt`s first two coiled pipeline projects.« less

  17. 32 CFR 644.391 - Predisposal conference.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... economy of the local community. For this purpose, installations, in many cases, will be reported to GSA... will be developed in conjunction with appropriate using command and GSA representatives. Its purpose...

  18. Emerging Technologies for Real-Time Continuous Monitoring of Wellbore Integrity

    NASA Astrophysics Data System (ADS)

    Freifeld, B. M.

    2017-12-01

    Assessment of a well's integrity has traditionally been carried out through periodic wireline logging, often performed only when an operational problem was noted at the surface. There are several emerging technologies that can be installed permanently as part of the well completion and offer the ability to monitor operations while providing continuous indicators to evaluate the structural health of a well. Permanent behind casing instrumentation, such as pressure and temperature gauges can monitor for behind casing leakage. Similarly, fiber-optic distributed temperature and acoustic sensing provide additional information for assessing unwanted movement of fluid, which is indicative of problems either inside or outside of casing. Furthermore, these technologies offer the benefit of providing real-time continuous streams of information that serve as leading-indicators of wellbore problems to allow for early intervention. Additional research is still needed to develop best practices for the installation and operation of these technologies, as they increase cost and add additional risks that must be managed.

  19. Using the Spatial Distribution of Installers to Define Solar Photovoltaic Markets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Shaughnessy, Eric; Nemet, Gregory F.; Darghouth, Naim

    2016-09-01

    Solar PV market research to date has largely relied on arbitrary jurisdictional boundaries, such as counties, to study solar PV market dynamics. This paper seeks to improve solar PV market research by developing a methodology to define solar PV markets. The methodology is based on the spatial distribution of solar PV installers. An algorithm is developed and applied to a rich dataset of solar PV installations to study the outcomes of the installer-based market definitions. The installer-based approach exhibits several desirable properties. Specifically, the higher market granularity of the installer-based approach will allow future PV market research to study themore » relationship between market dynamics and pricing with more precision.« less

  20. 40 CFR 146.12 - Construction requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... potential, porosity, and gamma ray logs before the casing is installed; (B) Fracture finder logs; and (C) A... wells: (1) Fluid pressure; (2) Temperature; (3) Fracture pressure; (4) Other physical and chemical...

  1. 40 CFR 146.12 - Construction requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... potential, porosity, and gamma ray logs before the casing is installed; (B) Fracture finder logs; and (C) A... wells: (1) Fluid pressure; (2) Temperature; (3) Fracture pressure; (4) Other physical and chemical...

  2. 40 CFR 146.12 - Construction requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... potential, porosity, and gamma ray logs before the casing is installed; (B) Fracture finder logs; and (C) A... wells: (1) Fluid pressure; (2) Temperature; (3) Fracture pressure; (4) Other physical and chemical...

  3. Efficient Solutions for Existing Homes Case Study: Demonstration House of Cold-Climate Solutions for Affordable Housing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    T. Schirber, C. Ojczyk, and R. Jacobson

    2016-05-01

    Single family homes in urban areas that are available for renovation by nonprofit developers are often in rough shape (1MM to 2MM nationally). Budgeting has historically focused on improving homes to meet basic housing standards. A rising interest in the long-term impact of homeownership has introduced the need to balance basic needs with home performance. This demonstration project aims to help nonprofit affordable housing developers become familiar with three Building America performance measures, the installation processes, and impacts and benefits of each. A story and a half home in North Minneapolis, MN was presented by Urban Homeworks our local nonprofitmore » partner. The team helped them install three researched upgrade measures: exterior roof insulation or 'overcoat,' exterior foundation insulation, or 'excavationless', and a combined space and water heating HVAC system or 'combi.'« less

  4. Comparison of the Intensity of Ventilation at Windows Exchange in the Room - Case Study

    NASA Astrophysics Data System (ADS)

    Kapalo, Peter; Voznyak, Orest

    2017-06-01

    Doing the replacement of old wooden windows in a new plastic windows, in the old buildings, we get the great reducing of the building heat loss. Simpler maintenance and attendance of window is the next advantage. New windows are characterized by better tightness. The aim of the article is determination due to the performed experimental measurements, how much more are reduce the uncontrolled ventilation that is caused of the infiltration windows. In the article there is presented the experimental measurement of indoor air quality in the room in two phases. In the first phase there is the room installed by 55 year old wood window. In the second phase there is the same room installed by new plastic window. Due to the experimental measurement of indoor air quality it is calculated intensity of ventilation - infiltration. These results of ventilation intensity are reciprocally compared.

  5. Ranking of Sites for Installation of Hydropower Plant Using MLP Neural Network Trained with GA: A MADM Approach

    PubMed Central

    Singh, Kh. Manglem; Khelchandra, Thongam; Mehta, R. K.

    2017-01-01

    Every energy system which we consider is an entity by itself, defined by parameters which are interrelated according to some physical laws. In recent year tremendous importance is given in research on site selection in an imprecise environment. In this context, decision making for the suitable location of power plant installation site is an issue of relevance. Environmental impact assessment is often used as a legislative requirement in site selection for decades. The purpose of this current work is to develop a model for decision makers to rank or classify various power plant projects according to multiple criteria attributes such as air quality, water quality, cost of energy delivery, ecological impact, natural hazard, and project duration. The case study in the paper relates to the application of multilayer perceptron trained by genetic algorithm for ranking various power plant locations in India. PMID:28331490

  6. RF Coupling into the Fuel Tank of a Large Transport Aircraft from Intentionally Transmitting Peds in the Passenger Cabin

    NASA Technical Reports Server (NTRS)

    Nguyen, Truong X.; Dudley, Kenneth L.; Scearce, Stephen A.; Ely, Jay J.; Richardson, Robert E.; Hatfield, Michael O.

    2000-01-01

    An investigation was performed to study the potential for radio frequency (RF) power radiated from Portable Electronic Devices (PEDs) to create an arcing/sparking event within the fuel tank of a large transport aircraft. This paper describes the experimental methods used for measuring RF coupling to the fuel tank and Fuel Quantity Indication System (FQIS) wiring from PED sources located in the passenger cabin. To allow comparison of voltage/current data obtained in a laboratory chamber FQIS installation to an actual aircraft FQIS installation, aircraft fuel tank RF reverberation characteristics were also measured. Results from the measurements, along with a survey of threats from typical intentional transmitting PEDs are presented. The resulting worst-case power coupled onto fuel tank FQIS wiring is derived. The same approach can be applied to measure RF coupling into various other aircraft systems.

  7. Ranking of Sites for Installation of Hydropower Plant Using MLP Neural Network Trained with GA: A MADM Approach.

    PubMed

    Shimray, Benjamin A; Singh, Kh Manglem; Khelchandra, Thongam; Mehta, R K

    2017-01-01

    Every energy system which we consider is an entity by itself, defined by parameters which are interrelated according to some physical laws. In recent year tremendous importance is given in research on site selection in an imprecise environment. In this context, decision making for the suitable location of power plant installation site is an issue of relevance. Environmental impact assessment is often used as a legislative requirement in site selection for decades. The purpose of this current work is to develop a model for decision makers to rank or classify various power plant projects according to multiple criteria attributes such as air quality, water quality, cost of energy delivery, ecological impact, natural hazard, and project duration. The case study in the paper relates to the application of multilayer perceptron trained by genetic algorithm for ranking various power plant locations in India.

  8. Visual privacy by context: proposal and evaluation of a level-based visualisation scheme.

    PubMed

    Padilla-López, José Ramón; Chaaraoui, Alexandros Andre; Gu, Feng; Flórez-Revuelta, Francisco

    2015-06-04

    Privacy in image and video data has become an important subject since cameras are being installed in an increasing number of public and private spaces. Specifically, in assisted living, intelligent monitoring based on computer vision can allow one to provide risk detection and support services that increase people's autonomy at home. In the present work, a level-based visualisation scheme is proposed to provide visual privacy when human intervention is necessary, such as at telerehabilitation and safety assessment applications. Visualisation levels are dynamically selected based on the previously modelled context. In this way, different levels of protection can be provided, maintaining the necessary intelligibility required for the applications. Furthermore, a case study of a living room, where a top-view camera is installed, is presented. Finally, the performed survey-based evaluation indicates the degree of protection provided by the different visualisation models, as well as the personal privacy preferences and valuations of the users.

  9. Technology Solutions Case Study: Duct in Conditioned Space in a Dropped Ceiling or Fur-down, Gainesville, Florida

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2014-09-01

    Forced-air distribution systems (duct systems) typically are installed out of sight for aesthetic reasons, most often in unconditioned areas such as attics or crawlspaces. Any leakage of air to or from the duct system in unconditioned space not only loses energy, but impacts home and equipment durability and indoor air quality. An obvious solution is to bring the duct system into the interior of the house, either by sealing the area where the ducts are installed (attic or crawlspace) or by building an interior cavity or chase above the ceiling plane (raised ceiling or fur-up chase) or below the ceilingmore » plane (dropped ceiling or fur-down) for the duct system. In this project, Building America Partnership for Improved Residential Construction team partnered with Tommy Williams Homes to implement an inexpensive, quick, and effective method of building a fur-down chase.« less

  10. 40 CFR 147.1655 - Requirements for wells authorized by permit.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... New York § 147.1655 Requirements for wells authorized by permit. (a) The owner or operator of a Class... largest casing string. (b) The owner or operator of a new Class II well authorized by permit shall: (1... volume. (3) For new enhanced recovery wells, install tubing or long string casing extending to the...

  11. 77 FR 50855 - Oil and Gas and Sulphur Operations on the Outer Continental Shelf-Increased Safety Measures for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-22

    ... according to the design. The third- subsea function and pressure tests party verification must include...; Requires new casing and cementing integrity tests; Establishes new requirements for subsea secondary BOP... that, for the final casing string (or liner if it is the final string), an operator must install one...

  12. 40 CFR 89.328 - Inlet and exhaust restrictions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... at maximum air flow, as specified by the engine manufacturer for a clean air cleaner. A system representative of the installed engine may be used. In other cases a test shop system may be used. (2) The... cases a test shop system may be used. [59 FR 31335, June 17, 1994. Redesignated and amended at 63 FR...

  13. 40 CFR 89.328 - Inlet and exhaust restrictions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... at maximum air flow, as specified by the engine manufacturer for a clean air cleaner. A system representative of the installed engine may be used. In other cases a test shop system may be used. (2) The... cases a test shop system may be used. [59 FR 31335, June 17, 1994. Redesignated and amended at 63 FR...

  14. 40 CFR 89.328 - Inlet and exhaust restrictions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... at maximum air flow, as specified by the engine manufacturer for a clean air cleaner. A system representative of the installed engine may be used. In other cases a test shop system may be used. (2) The... cases a test shop system may be used. [59 FR 31335, June 17, 1994. Redesignated and amended at 63 FR...

  15. 40 CFR 89.328 - Inlet and exhaust restrictions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... at maximum air flow, as specified by the engine manufacturer for a clean air cleaner. A system representative of the installed engine may be used. In other cases a test shop system may be used. (2) The... cases a test shop system may be used. [59 FR 31335, June 17, 1994. Redesignated and amended at 63 FR...

  16. 40 CFR 89.328 - Inlet and exhaust restrictions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... at maximum air flow, as specified by the engine manufacturer for a clean air cleaner. A system representative of the installed engine may be used. In other cases a test shop system may be used. (2) The... cases a test shop system may be used. [59 FR 31335, June 17, 1994. Redesignated and amended at 63 FR...

  17. Calibration and verification of models of organic carbon removal kinetics in Aerated Submerged Fixed-Bed Biofilm Reactors (ASFBBR): a case study of wastewater from an oil-refinery.

    PubMed

    Trojanowicz, Karol; Wójcik, Włodzimierz

    2011-01-01

    The article presents a case-study on the calibration and verification of mathematical models of organic carbon removal kinetics in biofilm. The chosen Harremöes and Wanner & Reichert models were calibrated with a set of model parameters obtained both during dedicated studies conducted at pilot- and lab-scales for petrochemical wastewater conditions and from the literature. Next, the models were successfully verified through studies carried out utilizing a pilot ASFBBR type bioreactor installed in an oil-refinery wastewater treatment plant. During verification the pilot biofilm reactor worked under varying surface organic loading rates (SOL), dissolved oxygen concentrations and temperatures. The verification proved that the models can be applied in practice to petrochemical wastewater treatment engineering for e.g. biofilm bioreactor dimensioning.

  18. Diatomite filtration of water for injection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olmsted, B.C. Jr.; Bell, G.R.

    1966-01-01

    A discussion is presented of the capabilities, problems, and answers, in the performance of diatomite filters. The discussion includes a description of diatomite filtration, new developments, design criteria, and some case histories. Diatomite filters, when properly designed and installed, and when properly applied, can provide effective clarification of waters for injection at low capital and operating costs. Design, installation, and proper application, effectiveness, and capital and operating costs can be placed in the proper perspective in the light of general experience and recent pilot plant tests in the southern California area. (30 refs.)

  19. Business Case for Fuel Cells 2016

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Curtin, Sandra; Gangi, Jennifer; Benjamin, Thomas G.

    The report provides an overview of recent private sector fuel cell installations at U.S. businesses as of December 31, 2016. This list is by no means exhaustive. Over the past few decades, hundreds of thousands of fuel cells have been installed around the world, for primary or backup power, as well as in various other applications including portable and emergency backup power. Fuel cells have also been deployed in other applications such as heat and electricity for homes and apartments, material handling, passenger vehicles, buses, and remote, off-grid sites.

  20. Economic impact and policy implications from urban shared transportation: The case of Pittsburgh’s shared bike system

    PubMed Central

    Zacharias, Christos; Kokkodis, Marios; Lappas, Theodoros

    2017-01-01

    During the last years the number of cities that have installed and started operating shared bike systems has significantly increased. These systems provide an alternative and sustainable mean of transportation to the city dwellers. Apart from the energy sustainability benefits, shared bike systems can have a positive effect on residents’ health, air quality and the overall condition of the currently crumbling road network infrastructure. Anecdotal stories and survey studies have also identified that bike lanes have a positive impact on local businesses. In this study, driven by the rapid adoption of shared bike systems by city governments and their potential positive effects on a number of urban life facets we opt to study and quantify the value of these systems. We focus on a specific aspect of this value and use evidence from the real estate market in the city of Pittsburgh to analyze the effect on dwellers’ properties of the shared bike system installed in the city in June 2015. We use quasi-experimental techniques and find that the shared bike system led to an increase in the housing prices (both sales and rental prices) in the zip codes where shared bike stations were installed. We further bring into the light potential negative consequences of this impact (i.e., gentrification) and discuss/propose two public policies that can exploit the impact of the system for the benefit of both the local government as well as the city dwellers. PMID:28859121

  1. Economic impact and policy implications from urban shared transportation: The case of Pittsburgh's shared bike system.

    PubMed

    Pelechrinis, Konstantinos; Zacharias, Christos; Kokkodis, Marios; Lappas, Theodoros

    2017-01-01

    During the last years the number of cities that have installed and started operating shared bike systems has significantly increased. These systems provide an alternative and sustainable mean of transportation to the city dwellers. Apart from the energy sustainability benefits, shared bike systems can have a positive effect on residents' health, air quality and the overall condition of the currently crumbling road network infrastructure. Anecdotal stories and survey studies have also identified that bike lanes have a positive impact on local businesses. In this study, driven by the rapid adoption of shared bike systems by city governments and their potential positive effects on a number of urban life facets we opt to study and quantify the value of these systems. We focus on a specific aspect of this value and use evidence from the real estate market in the city of Pittsburgh to analyze the effect on dwellers' properties of the shared bike system installed in the city in June 2015. We use quasi-experimental techniques and find that the shared bike system led to an increase in the housing prices (both sales and rental prices) in the zip codes where shared bike stations were installed. We further bring into the light potential negative consequences of this impact (i.e., gentrification) and discuss/propose two public policies that can exploit the impact of the system for the benefit of both the local government as well as the city dwellers.

  2. Comparing U.S. Army suicide cases to a control sample: initial data and methodological lessons.

    PubMed

    Alexander, Cynthia L; Reger, Mark A; Smolenski, Derek J; Fullerton, Nicole R

    2014-10-01

    Identification of risk and protective factors for suicide is a priority for the United States military, especially in light of the recent steady increase in military suicide rates. The Department of Defense Suicide Event Report contains comprehensive data on suicides for active duty military personnel, but no analogous control data is available to permit identification of factors that differentially determine suicide risk. This proof-of-concept study was conducted to determine the feasibility of collecting such control data. The study employed a prospective case-control design in which control cases were randomly selected from a large Army installation at a rate of four control participants for every qualifying Army suicide. Although 111 Army suicides were confirmed during the study period, just 27 control soldiers completed the study. Despite the small control sample, preliminary analyses comparing suicide cases to controls identified several factors more frequently reported for suicide cases, including recent failed intimate relationships, outpatient mental health history, mood disorder diagnosis, substance abuse history, and prior self-injury. No deployment-related risk factors were found. These data are consistent with existing literature and form a foundation for larger control studies. Methodological lessons learned regarding study design and recruitment are discussed to inform future studies. Reprint & Copyright © 2014 Association of Military Surgeons of the U.S.

  3. 7 CFR 3300.7 - General.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... phases: (a) Measurement of the insulating capacity, that is, the K-coefficient, of the insulated body. (b) Determination of the efficiency of the thermal appliance as installed in the insulated body. In the case of...

  4. Planning, implementation, and history of the first 5 years of operation of the Craig, Alaska, pool and school biomass heating system—a case study

    Treesearch

    Allen M. Brackley; K. Petersen

    2016-01-01

    A wood-based energy project in Craig, Alaska, to heat the community's aquatic center and two of its schools was the first such installation in Alaska to convert from fossil fuels to a renewable energy source. Initial interest in the project started in 2004. The system came online in April 2008. This report provides an overview of the new heating system's...

  5. Lean, Mean, and Green: An Expeditionary Imperative

    DTIC Science & Technology

    2010-04-29

    possible to the USMC Expeditionary Power and Energy Symposium in New Orleans, LA. I would be remiss if I did not acknowledge the patience and support...mindsets are akin to fielding a new , lethal weapons system. 3 II. Soviet/Afghan War Case Study American forces can gain perspective on this issue, and...the nation’s capital, Kabul. 11 The Soviets intended to swiftly install a new pro-Moscow govemment followed by garrison duty, rather than entering

  6. DOE Zero Energy Ready Home Case Study: Palo Duro Homes, Albuquerque, New Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2013-09-01

    Palo Duro uses advanced framing techniques like 2x6 24-inch on-center framing, open headers above windows on non-load-bearing walls, 2-stud corners, ladder blocking where walls intersect, and single top and bottom plates. These techniques reduce the amount of lumber in the wall, allowing more room for insulation and reducing costs and installation time. The builder garnered a 2013 Housing Innovation Award in the production builder category.

  7. KENNEDY SPACE CENTER, FLA. - Armando Oliu, Final Inspection Team lead for the Shuttle program, speaks to reporters about the aid the Image Analysis Lab is giving the FBI in a kidnapping case. Behind him at right is Mike Rein, External Affairs division chief. Oliu oversees the image lab that is using an advanced SGI® TP9500 data management system to review the tape of the kidnapping in progress in Sarasota, Fla. KSC installed the new $3.2 million system in preparation for Return to Flight of the Space Shuttle fleet. The lab is studying the Sarasota kidnapping video to provide any new information possible to law enforcement officers. KSC is joining NASA’s Marshall Space Flight Center in Alabama in reviewing the tape.

    NASA Image and Video Library

    2004-02-04

    KENNEDY SPACE CENTER, FLA. - Armando Oliu, Final Inspection Team lead for the Shuttle program, speaks to reporters about the aid the Image Analysis Lab is giving the FBI in a kidnapping case. Behind him at right is Mike Rein, External Affairs division chief. Oliu oversees the image lab that is using an advanced SGI® TP9500 data management system to review the tape of the kidnapping in progress in Sarasota, Fla. KSC installed the new $3.2 million system in preparation for Return to Flight of the Space Shuttle fleet. The lab is studying the Sarasota kidnapping video to provide any new information possible to law enforcement officers. KSC is joining NASA’s Marshall Space Flight Center in Alabama in reviewing the tape.

  8. DEVELOPING AN INTEGRATED MANAGEMENT SYSTEM FOR URBAN AND ENERGY PLANNING TOWARDS A LOW-CARBON CITY

    NASA Astrophysics Data System (ADS)

    Maeda, Hideto; Nakakubo, Toyohiko; Tokai, Akihiro

    In this study, we developed an integrated management model that supports local government to make a promising energy saving measure on a block-scale combined with urban planning. We applied the model to Osaka city and estimated CO2 emissions from the residential and commercial buildings to 2050. The urban renewal cases selected in this study included advanced multipole accumulation case, normal multipole accumulation case, and actual trend continuation case. The energy saving options introduced in each case included all-electric HP system, micro grid system, and we also set the option where the greater CO2 reduction one is selected in each block. The results showed that CO2 emission in 2050 would be reduced by 54.8-57.6% relative to the actual condition by introducing the new energy system in all cases. In addition, the amount of CO2 reduction in actual trend continuation case was highest. The major factor was that the effect of CO2 emission reductions by installing the solar power generation panel was higher than the effect by utilizing heated water mutually on the high-density blocks in terms of total urban buildings' energy consumption.

  9. MindSeer: a portable and extensible tool for visualization of structural and functional neuroimaging data

    PubMed Central

    Moore, Eider B; Poliakov, Andrew V; Lincoln, Peter; Brinkley, James F

    2007-01-01

    Background Three-dimensional (3-D) visualization of multimodality neuroimaging data provides a powerful technique for viewing the relationship between structure and function. A number of applications are available that include some aspect of 3-D visualization, including both free and commercial products. These applications range from highly specific programs for a single modality, to general purpose toolkits that include many image processing functions in addition to visualization. However, few if any of these combine both stand-alone and remote multi-modality visualization in an open source, portable and extensible tool that is easy to install and use, yet can be included as a component of a larger information system. Results We have developed a new open source multimodality 3-D visualization application, called MindSeer, that has these features: integrated and interactive 3-D volume and surface visualization, Java and Java3D for true cross-platform portability, one-click installation and startup, integrated data management to help organize large studies, extensibility through plugins, transparent remote visualization, and the ability to be integrated into larger information management systems. We describe the design and implementation of the system, as well as several case studies that demonstrate its utility. These case studies are available as tutorials or demos on the associated website: . Conclusion MindSeer provides a powerful visualization tool for multimodality neuroimaging data. Its architecture and unique features also allow it to be extended into other visualization domains within biomedicine. PMID:17937818

  10. MindSeer: a portable and extensible tool for visualization of structural and functional neuroimaging data.

    PubMed

    Moore, Eider B; Poliakov, Andrew V; Lincoln, Peter; Brinkley, James F

    2007-10-15

    Three-dimensional (3-D) visualization of multimodality neuroimaging data provides a powerful technique for viewing the relationship between structure and function. A number of applications are available that include some aspect of 3-D visualization, including both free and commercial products. These applications range from highly specific programs for a single modality, to general purpose toolkits that include many image processing functions in addition to visualization. However, few if any of these combine both stand-alone and remote multi-modality visualization in an open source, portable and extensible tool that is easy to install and use, yet can be included as a component of a larger information system. We have developed a new open source multimodality 3-D visualization application, called MindSeer, that has these features: integrated and interactive 3-D volume and surface visualization, Java and Java3D for true cross-platform portability, one-click installation and startup, integrated data management to help organize large studies, extensibility through plugins, transparent remote visualization, and the ability to be integrated into larger information management systems. We describe the design and implementation of the system, as well as several case studies that demonstrate its utility. These case studies are available as tutorials or demos on the associated website: http://sig.biostr.washington.edu/projects/MindSeer. MindSeer provides a powerful visualization tool for multimodality neuroimaging data. Its architecture and unique features also allow it to be extended into other visualization domains within biomedicine.

  11. Meals on Wheels? A Decade of Megafaunal Visual and Acoustic Observations from Offshore Oil & Gas Rigs and Platforms in the North and Irish Seas.

    PubMed

    Todd, Victoria Louise Georgia; Warley, Jane Clare; Todd, Ian Boyer

    2016-01-01

    A decade of visual and acoustic detections of marine megafauna around offshore Oil & Gas (O&G) installations in the North and Irish Seas are presented. Marine megafauna activity was monitored visually and acoustically by Joint Nature Conservation Committee (JNCC) qualified and experienced Marine Mammal Observers (MMO) and Passive Acoustic Monitoring (PAM) Operators respectively, with real-time towed PAM in combination with industry standard software, PAMGuard. Monitoring was performed during routine O&G industrial operations for underwater noise mitigation purposes, and to ensure adherence to regulatory guidelines. Incidental sightings by off-effort MMOs and installation crew were also reported. Visual and acoustic monitoring spanned 55 non-consecutive days between 2004 and 2014. A total of 47 marine mammal sightings were recorded by MMOs on dedicated watch, and 10 incidental sightings of marine megafauna were reported over 10 years. Species included: harbour porpoise (Phocoena phocoena), Atlantic white-sided dolphin (Lagenorhynchus acutus), white beaked dolphin (Lagenorhynchus albirostris), common dolphin (Delphinus delphis), minke whale (Balaenoptera acutorostrata), common seal (Phoca vitulina), grey seal (Halichoerus grypus) and, basking shark (Cetorhinus maximus). Passive Acoustic Monitoring was conducted on two occasions in 2014; 160 PAM hours over 12 days recorded a total of 308 individual clicks identified as harbour porpoises. These appear to be the first such acoustic detections obtained from a North Sea drilling rig whilst using a typically configured hydrophone array designed for towing in combination with real-time PAMGuard software. This study provides evidence that marine megafauna are present around mobile and stationary offshore O&G installations during routine operational activities. On this basis, Environmental Impact Assessments (EIAs) for decommissioning O&G platforms should be carried-out on a case-by-case basis, and must include provisions for hitherto overlooked marine megafauna.

  12. How reliable are odour assessments?

    PubMed

    Bokowa, A; Beukes, J A

    2012-01-01

    This paper will demonstrate the differences found in odour test results, when odour sampling is performed at the same sources by two different consultants. By examining two case studies, this paper will highlight that the difference between the results can be significant. Both studies are based on odour sampling programs determining the odour removal efficiency of odour control units installed at two different facilities: a pet food facility and an oil/grease recycling facility. The first study is based on odour measurements at the inlet and outlet of the unit installed by Applied Plasma Physics AS at the pet food facility. Odour assessments were performed by two separate consultants at the same time. The second study is based on testing of the odour removal effectiveness of two units: a scrubber and a biofilter at an oil/grease recycling facility. During this study two odour sampling programs were performed by two consultants at different times, but under the same process conditions. This paper will show how varying results can play a role in choosing the adequate odour control technologies. The final results suggest that although, an odour control unit may appear to be insufficient, it actually is successful at removing the odours.

  13. FIELD STUDIES OF GEOMEMBRANE INSTALLATION TECHNIQUES

    EPA Science Inventory

    Fourteen construction sites where geomembranes were being installed were visited to observe subgrade preparation and liner installation techniques. These sites were visited during a study conducted for the U.S. EPA, Solid and Hazardous Waste Research Division. The sites included ...

  14. Using Residential Solar PV Quote Data to Analyze the Relationship Between Installer Pricing and Firm Size

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Shaughnessy, Eric; Margolis, Robert

    2017-05-18

    We use residential solar photovoltaic (PV) quote data to study the role of firm size in PV installer pricing. We find that large installers (those that installed more than 1,000 PV systems in any year from 2013 to 2015) quote higher prices for customer-owned systems, on average, than do other installers. The results suggest that low prices are not the primary value proposition of large installers.

  15. Using Residential Solar PV Quote Data to Analyze the Relationship Between Installer Pricing and Firm Size

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Shaughnessy, Eric; Margolis, Robert

    2017-05-19

    We use residential solar photovoltaic (PV) quote data to study the role of firm size in PV installer pricing. We find that large installers (those that installed more than 1,000 PV systems in any year from 2013 to 2015) quote higher prices for customer-owned systems, on average, than do other installers. The results suggest that low prices are not the primary value proposition of large installers.

  16. Landslide hazard analysis for pipelines: The case of the Simonette river crossing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grivas, D.A.; Schultz, B.C.; O`Neil, G.

    1995-12-31

    The overall objective of this study is to develop a probabilistic methodology to analyze landslide hazards and their effects on the safety of buried pipelines. The methodology incorporates a range of models that can accommodate differences in the ground movement modes and the amount and type of information available at various site locations. Two movement modes are considered, namely (a) instantaneous (catastrophic) slides, and (b) gradual ground movement which may result in cumulative displacements over the pipeline design life (30--40 years) that are in excess of allowable values. Probabilistic analysis is applied in each case to address the uncertainties associatedmore » with important factors that control slope stability. Availability of information ranges from relatively well studied, instrumented installations to cases where data is limited to what can be derived from topographic and geologic maps. The methodology distinguishes between procedures applied where there is little information and those that can be used when relatively extensive data is available. important aspects of the methodology are illustrated in a case study involving a pipeline located in Northern Alberta, Canada, in the Simonette river valley.« less

  17. PV systems for remote villages: Service-learning and communal sharing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duffy, J.; Soper, P.; Prasitpianchai, S.

    1999-07-01

    The remote village of Malvas in the Andes seems typical of many in Peru. The 500 descendants of the Quechua once ruled by the Inca have no electricity, no running water, one telephone, and mud adobe houses. At a 10,000-foot altitude, residents survive with subsistence farming. A group designed and installed a photovoltaic system to provide a vaccine refrigerator, lights, and a transceiver radio system in the town medical clinic last August. They installed light systems in four other town medical clinics in January. This project involves service-learning: combining service with academic subject matter, in this case solar engineering. Keymore » elements of the project also include: letting people define their needs, sustainable infrastructure development, community sharing of installation and virtual ownership (to go along with almost everything else that is shared in common).« less

  18. Long-term acceptability, durability and bio-efficacy of ZeroVector® durable lining for vector control in Papua New Guinea.

    PubMed

    Kuadima, Joseph J; Timinao, Lincoln; Naidi, Laura; Tandrapah, Anthony; Hetzel, Manuel W; Czeher, Cyrille; Pulford, Justin

    2017-02-28

    This study examined the acceptability, durability and bio-efficacy of pyrethroid-impregnated durable lining (DL) over a three-year period post-installation in residential homes across Papua New Guinea (PNG). ZeroVector ® ITPS had previously been installed in 40 homes across four study sites representing a cross section of malaria transmission risk and housing style. Structured questionnaires, DL visual inspections and group interviews (GIs) were completed with household heads at 12- and 36-months post-installation. Three DL samples were collected from all households in which it remained 36-months post-installation to evaluate the bio-efficacy of DL on Anopheles mosquitoes. Bio-efficacy testing followed WHO guidelines for the evaluation of indoor residual spraying. The DL was still intact in 86 and 39% of study homes at the two time periods, respectively. In homes in which the DL was still intact, 92% of household heads considered the appearance at 12-months post installation to be the same as, or better than, that at installation compared to 59% at 36-months post-installation. GIs at both time points confirmed continuing high acceptance of DL, based in large part of the perceived attractiveness and functionality of the material. However, participants frequently asserted that they, or their family members, had ceased or reduced their use of mosquito nets as a result of the DL installation. A total of 16 houses were sampled for bio-efficacy testing across the 4 study sites at 36-months post-installation. Overall, combining all sites and samples, both knock-down at 30 min and mortality at 24 h were 100%. The ZeroVector ® DL installation remained highly acceptable at 36-months post-installation, the material and fixtures proved durable and the efficacy against malaria vectors did not decrease. However, the DL material had been removed from over 50% of the original study homes 3 years post-installation, largely due to deteriorating housing infrastructure. Furthermore, the presence of the DL installation appeared to reduce ITN use among many participating householders. The study findings suggest DL may not be an appropriate vector control method for large-scale use in the contemporary PNG malaria control programme.

  19. Tuberculosis among nonimmigrant visitors to US Military installations.

    PubMed

    Aaron, Christopher L; Fotinos, Meletios J; West, Kevin B; Goodwin, Donald J; Mancuso, James D

    2013-03-01

    Nonimmigrant visitors are not required to be evaluated for tuberculosis (TB) before entering the country. Little literature exists describing the challenges of TB control among this demographic. This report reviews the challenges in managing TB in this population on U.S. military installations. Six cases were identified from reportable medical event reports. Information was obtained from public health personnel via phone interviews. Verified cases from 2004 to 2011 were included. Challenges were congruent among locations including: lack of procedures to screen for infection and disease among individuals at time of entry allowing one case to be admitted with acquired immunodeficiency syndrome and another concurrently on treatment for active TB; delays in the diagnosis of active TB as median time from entry to diagnosis was 62 days; and the need to conduct an effective contact investigation as the mean contact index was 77 including 1 secondary case of active TB. These cases emphasize the need for screening for TB in visitors from high-risk countries at time of entry, prompt diagnosis and treatment if found, procedures for evaluation of contacts, and interjurisdictional cooperation in large contact investigations. These challenges are common to nonimmigrants in both military and civilian settings. Reprint & Copyright © 2013 Association of Military Surgeons of the U.S.

  20. Assessment of exposure to EMF in a Danish case-control study of childhood cancer.

    PubMed

    Jensen, J K; Olsen, J H; Folkersen, E

    1994-01-01

    In Denmark it is permitted to draw overhead lines across residential areas. In connection with a Danish case-control study we developed a method for estimating the historical values of magnetic fields at residences. The study included 1,707 cases with childhood cancer and 4,788 matched population controls. A total of 16,082 different addresses had been occupied by the families from the time of conception until the date of diagnosis. The values of the extreme, maximum, middle and minimum 50 Hz magnetic field strengths originating from a 50-400 kV high-voltage installation were estimated for each of the dwellings included in a potential exposure area. 30 children were exposed to an average level of magnetic fields of 0.1 microT or more. The evaluated Danish method of exposure assessment was compared with the method for residential wiring codes developed by Wertheimer and Leeper /1/. We concluded that the US wiring codes are inappropriate for use in connection with the Danish electricity transmission system.

  1. 47 CFR 78.33 - Special temporary authority.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... facilities, a request may be made for special temporary authority to install and operate new equipment or to... with § 78.18: Provided, however, That in the case of events of widespread interest and importance that...

  2. 46 CFR 52.01-130 - Installation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... that for a cylindrical part of a boiler or a knuckle in the casing of a water-tube boiler, these... as necessary to prevent oil draining into the bilges. (c) Boiler uptakes. (1) Where dampers are...

  3. Two case studies in river naturalization: planform migration and bank erosion control

    NASA Astrophysics Data System (ADS)

    Abad, J. D.; Guneralp, I.; Rhoads, B. L.; Garcia, M. H.

    2005-05-01

    A sound understanding of river planform evolution and bank erosion control, along with integration of expertise from several disciplines is required for the development of predictive models for river naturalization. Over the last few years, several methodologies have been presented for naturalization projects, from purely heuristic to more advanced methods. Since the time and space scales of concern in naturalization vary widely, there is a need for appropriate tools at a variety of time and space scales. This study presents two case studies at different scales. The first case study describes the prediction of river planform evolution for a remeandering project based on a simplified two-dimensional hydrodynamic model. The second case study describes the applicability of a Computational Fluid Dynamics (CFD) model for evaluating the effectiveness of bank-erosion control structures in individual meander bends. Understanding the hydrodynamic influence of control structures on flow through bends allows accurate prediction of depositional and erosional distribution patterns, resulting in better assessment on river planform stability, especially for the case of natural complex systems. The first case study introduces a mathematical model for evolution of meandering rivers that can be used in remeandering projects. In United States in particular, several rivers have been channelized in the past causing environmental and ecological problems. Following Newton's third law, "for every action, there is a reaction", naturalization techniques evolve as natural reactive solutions to channelization. This model (herein referred as RVR Meander) can be used as a stand-alone Windows application or as module in a Geographic Information System. The model was applied to the Poplar Creek re-meanderization project and used to evaluate re-meandering alternatives for an approximately 800-meter long reach of Poplar Creek that was straightened in 1938. The second case study describes a streambank protection project using bendway weirs. In the State of Illinois, bendway weirs constructed of rock have been installed at hundreds of sites, especially on small streams, to control streambank erosion. Bendway weirs are low hard structures installed in the concave bank of a meander bend. Design criteria for these weirs are approximate and have not been rigorously evaluated for overall effectiveness at low-, medium- and high flows. This initial step of the study attempted to describe the hydrodynamics around the weirs and the influence of the hydrodynamic patterns on sediment transport (near-field and far-field). To do that, a state-of-the-art three-dimensional CFD model was used to simulate flow through meander bends where 3D velocity measurements have been obtained to validate model predictions at low stages. Results indicate that the weirs produce highly complex patterns of flow around the weirs, which in some cases may actually increase erosional potential near the outer bank. These two case studies represent components of an emerging initiative to develop predictive tools for naturalization over a range of spatial and temporal scales

  4. The Effect of Mounting Vortex Generators on the DTU 10MW Reference Wind Turbine Blade

    NASA Astrophysics Data System (ADS)

    Skrzypiński, Witold; Gaunaa, Mac; Bak, Christian

    2014-06-01

    The aim of the current work is to analyze possible advantages of mounting Vortex Generators (VG's) on a wind turbine blade. Specifically, the project aims at investigating at which radial sections of the DTU 10 MW Reference Wind Turbine blade it is most beneficial to mount the VG's in order to increase the Annual Energy Production (AEP) under realistic conditions. The present analysis was carried out in several steps: (1) The clean two dimensional airfoil characteristics were first modified to emulate the effect of all possible combinations of VG's (1% high at suction side x/c=0.2-0.25) and two Leading Edge Roughness (LER) values along the whole blade span. (2) The combinations from Step 1, including the clean case were subsequently modified to take into account three dimensional effects. (3) BEM computations were carried out to determine the aerodynamic rotor performance using each of the datasets from Step 2 along the whole blade span for all wind speeds in the turbine control scheme. (4) Employing the assumption of radial independence between sections of the blades, and using the results of the BEM computations described in Step 3, it is possible to determine for each radial position independently whether it is beneficial to install VG's in the smooth and LER cases, respectively. The results indicated that surface roughness that corresponds to degradation of the power curve may to some extent be mitigated by installation of VG's. The present results also indicated that the optimal VG configuration in terms of maximizing AEP depends on the degree of severity of the LER. This is because, depending on the condition of blade surface, installation of VG's on an incorrect blade span or installation of VG's too far out on the blade may cause loss in AEP. The results also indicated that the worse condition of the blade surface, the more gain may be obtained from the installation of VG's.

  5. [Risk factors for multidrug-resistant tuberculosis in the city of Kinshasa in the Democratic Republic of Congo].

    PubMed

    Misombo-Kalabela, André; Nguefack-Tsague, Georges; Kalla, Ginette Claude Mireille; Ze, Emmanuel Afane; Diangs, Kimpanga; Panda, Tshapenda; Kebela, Ilunga; Fueza, Serge Bisuta; Magazani, Nzanzu; Mbopi-Kéou, François-Xavier

    2016-01-01

    The aim of this study was to determine the risk factors for multidrug-resistant tuberculosis (TB) in the city of Kinshasa in the Democratic Republic of Congo. This was a case control study. The cases included all TB patients notified as resistant to rifampicin and isoniazid in Kinshasa from January 2012 to June 2013. The controls included TB patients treated during the same period as the cases and declared cured at the end of treatment. For this study, we obtained ethical clearance. The sample consisted of 213 participants, 132 men (62%) and 81 women (38%). The median age was 31 years (16-73 years). Factors associated with significant (p< 0,05) multidrug-resistant tuberculosis were the non-observance of the hours of taking drugs (0R = 111) (80% cases, 4% controls), the failure of treatment (0R = 20 (76% cases, 13% controls); the concept of multidrug-resistant tuberculosis in the family (0R = 6.4) (28% cases, 6% controls); a lack of knowledge of multidrug-resistant tuberculosis (0R = 3.2) (31% cases, 59% controls); a stay in prison (0R = 7.6) (10% cases, 1% controls) and the interruption of treatment (0R = 6.1) (59% cases, 19% controls). The emergence of multidrug-resistant tuberculosis can be avoided by the installation of suitable diagnosis and treatment strategies.

  6. An evaluation of energy-absorbing guide rail terminals in New Brunswick

    NASA Astrophysics Data System (ADS)

    Esligar, Ryan W.

    2011-12-01

    Energy-absorbing guide rail terminals (EAGRTs) are a form of end treatment designed to absorb energy during a collision and prevent intrusion into the impacting vehicle. After several years of use in New Brunswick there is evidence to suggest these systems may not always perform as expected. This study was conducted to evaluate the real-world performance of EAGRT systems in collisions throughout the Province. A retrospective review of data for 103 collisions that occurred prior to the study was supplemented with an in-depth analysis and reconstruction of 18 collisions that occurred during the study. The study revealed that two types of EAGRTs are used in New Brunswick; the ET-Plus and the SKT-350. Between 2007 and 2010 approximately 80% of all EAGRT collisions were PDO, nearly 19% resulted in injuries, while one collision resulted in a fatality. In most cases the EAGRT absorbed a significant amount of energy (an average of 315 KJ per crash); however, there were several problems identified. It was determined that not all EAGRT systems are being installed in accordance with the manufacturer's guidelines. Intrusion into the vehicle was documented in three collisions. It was also discovered that many of the collision configurations were different than the NCHRP Report 350 tests. The major recommendations focused on installation and maintenance issues identified during the study. The study also revealed areas in need of further research. These areas include the feasibility of using the FLEAT system in New Brunswick, the installation of rumble strips on the median shoulder, and whether or not additional crash test configurations should be incorporated into NCHRP Report 350 or Project 22-14(2).

  7. Airburst height computation method of Sea-Impact Test

    NASA Astrophysics Data System (ADS)

    Kim, Jinho; Kim, Hyungsup; Chae, Sungwoo; Park, Sungho

    2017-05-01

    This paper describes the ways how to measure the airburst height of projectiles and rockets. In general, the airburst height could be determined by using triangulation method or the images from the camera installed on the radar. There are some limitations in these previous methods when the missiles impact the sea surface. To apply triangulation method, the cameras should be installed so that the lines of sight intersect at angles from 60 to 120 degrees. There could be no effective observation towers to install the optical system. In case the range of the missile is more than 50km, the images from the camera of the radar could be useless. This paper proposes the method to measure the airburst height of sea impact projectile by using a single camera. The camera would be installed on the island near to the impact area and the distance could be computed by using the position and attitude of camera and sea level. To demonstrate the proposed method, the results from the proposed method are compared with that from the previous method.

  8. The Interaction of Solar wind Discontinuities with the Earth's Bow Shock

    NASA Technical Reports Server (NTRS)

    Sibeck, David G.

    2000-01-01

    Funding from NASA Grant No. NAG54679 was received in three installments. The first year's installment amounted to only one month of salary support and was used to prepare survey plots. The second year's installment allowed us to complete two research papers concerning the interaction of solar wind discontinuities with the Earth's bow shock. In the first (published) paper, we reported that the discontinuities launch slow mode waves into the magnetosheath and the slow mode waves always propagate antisunward through the flank magnetosheath. Because the sunward/antisunward sense of the magnetosheath magnetic field reverses across local noon, so does the (north/south or east/west) sense of the velocity fluctuations associated with the waves. Wind, Geotail, and IMP-8 observations were used for this study. In the second study, we used Wind and Interball-1 observations to demonstrate that pressure pulses in the magnetosheath occur in pairs and that they bound pressure cavities and/or brief intervals of outward magnetopause motion. This paper is now in press. Funding from the third year's installment has been used to investigate the two aspects of the foreshock. Two manuscripts are now in preparation for submission to the Journal of Geophysical Research. The first reports that waves within the foreshock account for many instances of poor correlations between two solar wind monitors. Remaining cases of poor correlation occur during intervals of nearly constant IMF orientations and magnetic field strengths. While the former category pose a significant difficulty for space weather forecasts, the latter do not. The second study surveys IMP-8 observations of the foreshock. We find that diamagnetic cavities are common, particularly during periods of high solar wind velocity and low solar wind density. Plasma densities, temperatures, and magnetic field strengths fall during intervals of enhanced energetic particle fluxes. The cavities are bounded by regions of decelerated solar wind plasma and enhanced densities and magnetic field strengths.

  9. Installation of child safety seats in selected 1988-1989 model year automobiles

    DOT National Transportation Integrated Search

    1989-06-01

    The study tested whether currently marketed child safety seats are difficult to install in current model automobiles. The study also tested whether once installed, the child seats remain securely fastened when rocked or tilted. Thirteen toddler and f...

  10. Crash history after installation of traffic signals : warranted vs. unwarranted.

    DOT National Transportation Integrated Search

    2008-01-01

    The objective of this study was to determine the change in crash history at intersections after installation of a traffic signal. Signals installed based on the warrants from an engineering study resulted in a decrease in angle collisions with an inc...

  11. Potential climatic impacts and reliability of large-scale offshore wind farms

    NASA Astrophysics Data System (ADS)

    Wang, Chien; Prinn, Ronald G.

    2011-04-01

    The vast availability of wind power has fueled substantial interest in this renewable energy source as a potential near-zero greenhouse gas emission technology for meeting future world energy needs while addressing the climate change issue. However, in order to provide even a fraction of the estimated future energy needs, a large-scale deployment of wind turbines (several million) is required. The consequent environmental impacts, and the inherent reliability of such a large-scale usage of intermittent wind power would have to be carefully assessed, in addition to the need to lower the high current unit wind power costs. Our previous study (Wang and Prinn 2010 Atmos. Chem. Phys. 10 2053) using a three-dimensional climate model suggested that a large deployment of wind turbines over land to meet about 10% of predicted world energy needs in 2100 could lead to a significant temperature increase in the lower atmosphere over the installed regions. A global-scale perturbation to the general circulation patterns as well as to the cloud and precipitation distribution was also predicted. In the later study reported here, we conducted a set of six additional model simulations using an improved climate model to further address the potential environmental and intermittency issues of large-scale deployment of offshore wind turbines for differing installation areas and spatial densities. In contrast to the previous land installation results, the offshore wind turbine installations are found to cause a surface cooling over the installed offshore regions. This cooling is due principally to the enhanced latent heat flux from the sea surface to lower atmosphere, driven by an increase in turbulent mixing caused by the wind turbines which was not entirely offset by the concurrent reduction of mean wind kinetic energy. We found that the perturbation of the large-scale deployment of offshore wind turbines to the global climate is relatively small compared to the case of land-based installations. However, the intermittency caused by the significant seasonal wind variations over several major offshore sites is substantial, and demands further options to ensure the reliability of large-scale offshore wind power. The method that we used to simulate the offshore wind turbine effect on the lower atmosphere involved simply increasing the ocean surface drag coefficient. While this method is consistent with several detailed fine-scale simulations of wind turbines, it still needs further study to ensure its validity. New field observations of actual wind turbine arrays are definitely required to provide ultimate validation of the model predictions presented here.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dillon, Heather E.; Antonopoulos, Chrissi A.; Solana, Amy E.

    As the model energy codes are improved to reach efficiency levels 50 percent greater than current codes, use of on-site renewable energy generation is likely to become a code requirement. This requirement will be needed because traditional mechanisms for code improvement, including envelope, mechanical and lighting, have been pressed to the end of reasonable limits. Research has been conducted to determine the mechanism for implementing this requirement (Kaufman 2011). Kaufmann et al. determined that the most appropriate way to structure an on-site renewable requirement for commercial buildings is to define the requirement in terms of an installed power density permore » unit of roof area. This provides a mechanism that is suitable for the installation of photovoltaic (PV) systems on future buildings to offset electricity and reduce the total building energy load. Kaufmann et al. suggested that an appropriate maximum for the requirement in the commercial sector would be 4 W/ft{sup 2} of roof area or 0.5 W/ft{sup 2} of conditioned floor area. As with all code requirements, there must be an alternative compliance path for buildings that may not reasonably meet the renewables requirement. This might include conditions like shading (which makes rooftop PV arrays less effective), unusual architecture, undesirable roof pitch, unsuitable building orientation, or other issues. In the short term, alternative compliance paths including high performance mechanical equipment, dramatic envelope changes, or controls changes may be feasible. These options may be less expensive than many renewable systems, which will require careful balance of energy measures when setting the code requirement levels. As the stringency of the code continues to increase however, efficiency trade-offs will be maximized, requiring alternative compliance options to be focused solely on renewable electricity trade-offs or equivalent programs. One alternate compliance path includes purchase of Renewable Energy Credits (RECs). Each REC represents a specified amount of renewable electricity production and provides an offset of environmental externalities associated with non-renewable electricity production. The purpose of this paper is to explore the possible issues with RECs and comparable alternative compliance options. Existing codes have been examined to determine energy equivalence between the energy generation requirement and the RECs alternative over the life of the building. The price equivalence of the requirement and the alternative are determined to consider the economic drivers for a market decision. This research includes case studies that review how the few existing codes have incorporated RECs and some of the issues inherent with REC markets. Section 1 of the report reviews compliance options including RECs, green energy purchase programs, shared solar agreements and leases, and other options. Section 2 provides detailed case studies on codes that include RECs and community based alternative compliance methods. The methods the existing code requirements structure alternative compliance options like RECs are the focus of the case studies. Section 3 explores the possible structure of the renewable energy generation requirement in the context of energy and price equivalence. The price of RECs have shown high variation by market and over time which makes it critical to for code language to be updated frequently for a renewable energy generation requirement or the requirement will not remain price-equivalent over time. Section 4 of the report provides a maximum case estimate for impact to the PV market and the REC market based on the Kaufmann et al. proposed requirement levels. If all new buildings in the commercial sector complied with the requirement to install rooftop PV arrays, nearly 4,700 MW of solar would be installed in 2012, a major increase from EIA estimates of 640 MW of solar generation capacity installed in 2009. The residential sector could contribute roughly an additional 2,300 MW based on the same code requirement levels of 4 W/ft{sup 2} of roof area. Section 5 of the report provides a basic framework for draft code language recommendations based on the analysis of the alternative compliance levels.« less

  13. Integrated modelling of stormwater treatment systems uptake.

    PubMed

    Castonguay, A C; Iftekhar, M S; Urich, C; Bach, P M; Deletic, A

    2018-05-24

    Nature-based solutions provide a variety of benefits in growing cities, ranging from stormwater treatment to amenity provision such as aesthetics. However, the decision-making process involved in the installation of such green infrastructure is not straightforward, as much uncertainty around the location, size, costs and benefits impedes systematic decision-making. We developed a model to simulate decision rules used by local municipalities to install nature-based stormwater treatment systems, namely constructed wetlands, ponds/basins and raingardens. The model was used to test twenty-four scenarios of policy-making, by combining four asset selection, two location selection and three budget constraint decision rules. Based on the case study of a local municipality in Metropolitan Melbourne, Australia, the modelled uptake of stormwater treatment systems was compared with attributes of real-world systems for the simulation period. Results show that the actual budgeted funding is not reliable to predict systems' uptake and that policy-makers are more likely to plan expenditures based on installation costs. The model was able to replicate the cumulative treatment capacity and the location of systems. As such, it offers a novel approach to investigate the impact of using different decision rules to provide environmental services considering biophysical and economic factors. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. AIDE - Advanced Intrusion Detection Environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Cathy L.

    2013-04-28

    Would you like to know when someone has dropped an undesirable executable binary on our system? What about something less malicious such as a software installation by a user? What about the user who decides to install a newer version of mod_perl or PHP on your web server without letting you know beforehand? Or even something as simple as when an undocumented config file change is made by another member of the admin group? Do you even want to know about all the changes that happen on a daily basis on your server? The purpose of an intrusion detection systemmore » (IDS) is to detect unauthorized, possibly malicious activity. The purpose of a host-based IDS, or file integrity checker, is check for unauthorized changes to key system files, binaries, libraries, and directories on the system. AIDE is an Open Source file and directory integrity checker. AIDE will let you know when a file or directory has been added, deleted, modified. It is included with the Red Hat Enterprise 6. It is available for other Linux distros. This is a case study describing the process of configuring AIDE on an out of the box RHEL6 installation. Its goal is to illustrate the thinking and the process by which a useful AIDE configuration is built.« less

  15. Design and implementation of relational databases relevant to the diverse needs of a tuberculosis case contact study in the Gambia.

    PubMed

    Jeffries, D J; Donkor, S; Brookes, R H; Fox, A; Hill, P C

    2004-09-01

    The data requirements of a large multidisciplinary tuberculosis case contact study are complex. We describe an ACCESS-based relational database system that meets our rigorous requirements for data entry and validation, while being user-friendly, flexible, exportable, and easy to install on a network or stand alone system. This includes the development of a double data entry package for epidemiology and laboratory data, semi-automated entry of ELISPOT data directly from the plate reader, and a suite of new programmes for the manipulation and integration of flow cytometry data. The double entered epidemiology and immunology databases are combined into a separate database, providing a near-real-time analysis of immuno-epidemiological data, allowing important trends to be identified early and major decisions about the study to be made and acted on. This dynamic data management model is portable and can easily be applied to other studies.

  16. On vortex bursting

    NASA Technical Reports Server (NTRS)

    Werle, H.

    1984-01-01

    Vortex bursting is studied by means of visualization. The physical behavior of the phenomenon is emphasized, and its similarity with boundary layer separation or wake bursting becomes apparent. The essential influence of an increasing pressure gradient on the initiation, the position and the type of bursting is clearly confirmed. The evolution of the phenomena as a function of several parameters is analyzed in the case of delta wings, alone or installed on aircraft models, and compared with the results of similar wind tunnel or flight tests.

  17. Structured Problem Solving and the Basic Graphic Methods within a Total Quality Leadership Setting: Case Study

    DTIC Science & Technology

    1992-02-01

    develop,, and maintains computer programs for the Department of the Navy. It provides life cycle support for over 50 computer programs installed at over...the computer programs . Table 4 presents a list of possible product or output measures of functionality for ACDS Block 0 programs . Examples of output...were identified as important "causes" of process performance. Functionality of the computer programs was the result or "effect" of the combination of

  18. Development of flat-plate solar plate collector: Evaporator

    NASA Astrophysics Data System (ADS)

    Abramzon, B.; Yaron, I.

    1981-11-01

    In the present study the thermal performance of a flat plate solar collector is analyzed theoretically for the case in which the working fluid may undergo a phase change within the tubes of the collector. In addition to the common domestic applications, such a collector - evaporator may be used as a generator of vapors for the production of mechanical or electrical energy, e.g., solar water pumps, solar power stations, etc., as well as for solar - powered absorption refrigeration machines, distillation installations, etc.

  19. Evaluating and optimizing the NERSC workload on Knights Landing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnes, T; Cook, B; Deslippe, J

    2017-01-30

    NERSC has partnered with 20 representative application teams to evaluate performance on the Xeon-Phi Knights Landing architecture and develop an application-optimization strategy for the greater NERSC workload on the recently installed Cori system. In this article, we present early case studies and summarized results from a subset of the 20 applications highlighting the impact of important architecture differences between the Xeon-Phi and traditional Xeon processors. We summarize the status of the applications and describe the greater optimization strategy that has formed.

  20. Evaluating and Optimizing the NERSC Workload on Knights Landing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnes, Taylor; Cook, Brandon; Doerfler, Douglas

    2016-01-01

    NERSC has partnered with 20 representative application teams to evaluate performance on the Xeon-Phi Knights Landing architecture and develop an application-optimization strategy for the greater NERSC workload on the recently installed Cori system. In this article, we present early case studies and summarized results from a subset of the 20 applications highlighting the impact of important architecture differences between the Xeon-Phi and traditional Xeon processors. We summarize the status of the applications and describe the greater optimization strategy that has formed.

  1. From soil in art towards Soil Art

    NASA Astrophysics Data System (ADS)

    Feller, C.; Landa, E. R.; Toland, A.; Wessolek, G.

    2015-02-01

    The range of art forms and genres dealing with soil is wide and diverse, spanning many centuries and artistic traditions, from prehistoric painting and ceramics to early Renaissance works in Western literature, poetry, paintings, and sculpture, to recent developments in cinema, architecture and contemporary art. Case studies focused on painting, installation, and cinema are presented with the view of encouraging further exploration of art about, in, with, or featuring soil or soil conservation issues, created by artists, and occasionally scientists, educators or collaborative efforts thereof.

  2. Effect of Component Failures on Economics of Distributed Photovoltaic Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lubin, Barry T.

    2012-02-02

    This report describes an applied research program to assess the realistic costs of grid connected photovoltaic (PV) installations. A Board of Advisors was assembled that included management from the regional electric power utilities, as well as other participants from companies that work in the electric power industry. Although the program started with the intention of addressing effective load carrying capacity (ELCC) for utility-owned photovoltaic installations, results from the literature study and recommendations from the Board of Advisors led investigators to the conclusion that obtaining effective data for this analysis would be difficult, if not impossible. The effort was then re-focusedmore » on assessing the realistic costs and economic valuations of grid-connected PV installations. The 17 kW PV installation on the University of Hartford's Lincoln Theater was used as one source of actual data. The change in objective required a more technically oriented group. The re-organized working group (changes made due to the need for more technically oriented participants) made site visits to medium-sized PV installations in Connecticut with the objective of developing sources of operating histories. An extensive literature review helped to focus efforts in several technical and economic subjects. The objective of determining the consequences of component failures on both generation and economic returns required three analyses. The first was a Monte-Carlo-based simulation model for failure occurrences and the resulting downtime. Published failure data, though limited, was used to verify the results. A second model was developed to predict the reduction in or loss of electrical generation related to the downtime due to these failures. Finally, a comprehensive economic analysis, including these failures, was developed to determine realistic net present values of installed PV arrays. Two types of societal benefits were explored, with quantitative valuations developed for both. Some societal benefits associated with financial benefits to the utility of having a distributed generation capacity that is not fossil-fuel based have been included into the economic models. Also included and quantified in the models are several benefits to society more generally: job creation and some estimates of benefits from avoiding greenhouse emissions. PV system failures result in a lowering of the economic values of a grid-connected system, but this turned out to be a surprisingly small effect on the overall economics. The most significant benefit noted resulted from including the societal benefits accrued to the utility. This provided a marked increase in the valuations of the array and made the overall value proposition a financially attractive one, in that net present values exceeded installation costs. These results indicate that the Department of Energy and state regulatory bodies should consider focusing on societal benefits that create economic value for the utility, confirm these quantitative values, and work to have them accepted by the utilities and reflected in the rate structures for power obtained from grid-connected arrays. Understanding and applying the economic benefits evident in this work can significantly improve the business case for grid-connected PV installations. This work also indicates that the societal benefits to the population are real and defensible, but not nearly as easy to justify in a business case as are the benefits that accrue directly to the utility.« less

  3. Statistical analysis of electromagnetic radiation measurements in the vicinity of GSM/UMTS base station installed on buildings in Serbia.

    PubMed

    Koprivica, Mladen; Slavkovic, Vladimir; Neskovic, Natasa; Neskovic, Aleksandar

    2016-03-01

    As a result of dense deployment of public mobile base stations, additional electromagnetic (EM) radiation occurs in the modern human environment. At the same time, public concern about the exposure to EM radiation emitted by such sources has increased. In order to determine the level of radio frequency radiation generated by base stations, extensive EM field strength measurements were carried out for 664 base station locations, from which 276 locations refer to the case of base stations with antenna system installed on buildings. Having in mind the large percentage (42 %) of locations with installations on buildings, as well as the inevitable presence of people in their vicinity, a detailed analysis of this location category was performed. Measurement results showed that the maximum recorded value of total electric field strength has exceeded International Commission on Non-Ionizing Radiation Protection general public exposure reference levels at 2.5 % of locations and Serbian national reference levels at 15.6 % of locations. It should be emphasised that the values exceeding the reference levels were observed only outdoor, while in indoor total electric field strength in no case exceeded the defined reference levels. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. A methodology to evaluate occupational internal exposure to fluorine-18.

    PubMed

    Oliveira, C M; Dantas, A L A; Dantas, B M

    2009-11-15

    The objective of this work is to develop procedures for internal monitoring of (18)F to be applied in cases of possible incorporation of fluoride and (18)FDG, using in vivo and in vitro methods of measurements. The Na I (Tl) 8" x 4" scintillation detector installed at IRD-Whole Body Counter was calibrated for measurements with a whole body anthropomorphic phantom, simulating homogeneous distribution of (18)F in the body. The NaI(Tl) 3"x 3" scintillation detector installed at the IRD-Whole Body Counter was calibrated for in vivo measurements with a brain phantom inserted in an artificial skull, simulating (18)FDG incorporation. The HPGe detection system installed at the IRD-Bioassay Laboratory was calibrated for in vitro measurements of urine samples with 1 liter plastic bottles containing a standard liquid source. A methodology for bioassay data interpretation, based on standard ICRP models edited with the software AIDE-version 6, was established. It is concluded that in vivo measurements have sufficient sensitivity for monitoring (18)F in the forms of fluoride and (18)FDG. The use of both in vitro and in vivo bioassay data can provide useful information for the interpretation of bioassay data in cases of accidental incorporation in order to identify the chemical form of (18)F incorporated.

  5. Building America Case Study: Trade-Friendly Retrofit Insulated Panels for Existing Buildings, Albany, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    This project evaluated the effectiveness and affordability of integrating retrofit insulated panels into a re-siding project. The Partnership for Home Innovation (PHI) teamed with New York State Energy Research and Development Authority (NYSERDA), the Albany Housing Authority (AHA), and the New York State Weatherization Assistance Program (WAP) administered by Albany Community Action Partnership to demonstrate an energy retrofit and siding upgrade on a two-story, seven unit, multifamily building in Albany New York (CZ 5). The project focused on accomplishing three goals - doubling the existing wall thermal resistance (from approximately R-13 to a weighted average of R-27), reduction of buildingmore » air leakage, and completion of the retrofit within a budget where the additional cost for upgrading wall's thermal resistance is equal to the cost of the standard re-siding effort (i.e., the total cost of the energy efficient re-siding scope of work is not more than double the cost of the standard re-siding effort). Lessons learned from the project strongly indicate that the retrofit panel technology can be installed using common installation practices and with minimal training. Other lessons learned include limitation on the use of standard air sealing materials during cold weather installations and the need to develop better installation guidance for trades working with the level of tolerances that may be present in the existing structure. This technology demonstration showed that exterior retrofit panels provide a viable and reasonable option for the siding trades to increase market opportunities and achieve synergistic benefits for aesthetic upgrades to a building's exterior.« less

  6. Building America Case Study: Field Trial of an Aerosol-Based Enclosure Sealing Technology, Clovis, California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    This report presents the results from several demonstrations of a new method for sealing building envelope air leaks using an aerosol sealing process developed by the Western Cooling Efficiency Center at UC Davis. The process involves pressurizing a building while applying an aerosol sealant to the interior. As air escapes through leaks in the building envelope, the aerosol particles are transported to the leaks where they collect and form a seal that blocks the leak. Standard blower door technology is used to facilitate the building pressurization, which allows the installer to track the sealing progress during the installation and automaticallymore » verify the final building tightness. Each aerosol envelope sealing installation was performed after drywall was installed and taped, and the process did not appear to interrupt the construction schedule or interfere with other trades working in the homes. The labor needed to physically seal bulk air leaks in typical construction will not be replaced by this technology. However, this technology is capable of bringing the air leakage of a building that was built with standard construction techniques and HERS-verified sealing down to levels that would meet DOE Zero Energy Ready Homes program requirements. When a developer is striving to meet a tighter envelope leakage specification, this technology could greatly reduce the cost to achieve that goal by providing a simple and relatively low cost method for reducing the air leakage of a building envelope with little to no change in their common building practices.« less

  7. The effectiveness of platform screen doors for the prevention of subway suicides in South Korea.

    PubMed

    Chung, Yong Woon; Kang, Sung Jin; Matsubayashi, Tetsuya; Sawada, Yasuyuki; Ueda, Michiko

    2016-04-01

    Subway suicide can significantly impact the general public. Platform Screen Doors (PSDs) are considered to be an effective strategy to prevent suicides at subway stations, but the evidence on their effectiveness is limited. We assessed the effectiveness of installing half- and full-height platform screen doors in reducing subway suicides using Poisson regression analysis. Ten-year monthly panel data for 121 subway stations between 2003 and 2012 in the Seoul metropolitan area were used for the analysis. We found that installing PSDs decreases fatal suicide cases by 89% (95% CI: 57-97%). We also found that the installation of full-height PSDs resulted in the elimination of subway suicides by completely blocking access to the track area; however, half-height PSDs, which do not extend to the ceiling of the platform, were not as effective as full-height ones. Our findings were based on the data from a single subway operator for a limited period of time. Accordingly, we did not consider the possibility that some passengers choose to die at a station run by other operators. Our study did not examine the potential substitution effects of other suicide methods. Installing physical barriers at subway stations can be an effective strategy to reduce the number of subway suicides; however, half-height PSDs are not as effective as full-height ones, even when they are as high as the height of an adult. Thus, these barriers should be made high enough so that nobody can climb over them. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Framework for the mapping of the monthly average daily solar radiation using an advanced case-based reasoning and a geostatistical technique.

    PubMed

    Lee, Minhyun; Koo, Choongwan; Hong, Taehoon; Park, Hyo Seon

    2014-04-15

    For the effective photovoltaic (PV) system, it is necessary to accurately determine the monthly average daily solar radiation (MADSR) and to develop an accurate MADSR map, which can simplify the decision-making process for selecting the suitable location of the PV system installation. Therefore, this study aimed to develop a framework for the mapping of the MADSR using an advanced case-based reasoning (CBR) and a geostatistical technique. The proposed framework consists of the following procedures: (i) the geographic scope for the mapping of the MADSR is set, and the measured MADSR and meteorological data in the geographic scope are collected; (ii) using the collected data, the advanced CBR model is developed; (iii) using the advanced CBR model, the MADSR at unmeasured locations is estimated; and (iv) by applying the measured and estimated MADSR data to the geographic information system, the MADSR map is developed. A practical validation was conducted by applying the proposed framework to South Korea. It was determined that the MADSR map developed through the proposed framework has been improved in terms of accuracy. The developed MADSR map can be used for estimating the MADSR at unmeasured locations and for determining the optimal location for the PV system installation.

  9. Occupational exposure to electromagnetic fields and sex-differential risk of uveal melanoma.

    PubMed

    Behrens, Thomas; Lynge, Elsebeth; Cree, Ian; Sabroe, Svend; Lutz, Jean-Michel; Afonso, Noemia; Eriksson, Mikael; Guénel, Pascal; Merletti, Franco; Morales-Suarez-Varela, Maria; Stengrevics, Aivars; Févotte, Joëlle; Llopis-González, Agustin; Gorini, Giuseppe; Sharkova, Galina; Hardell, Lennart; Ahrens, Wolfgang

    2010-11-01

    The association between occupational exposure to electromagnetic fields (EMF) and the risk of uveal melanoma was investigated in a case-control study in nine European countries. Incident cases of uveal melanoma and population as well as hospital controls were included and frequency matched by country, 5-year birth cohort and sex. Subjects were asked whether they had worked close to high-voltage electrical transmission installations, computer screens and various electrical machines, or in complex electrical environments. Measurements of two Scandinavian job-exposure matrices were applied to estimate lifelong cumulative EMF exposure. Unconditional logistic regression analyses, stratified by sex and eye colour were calculated, adjusting for several potential confounders. 293 patients with uveal melanoma and 3198 control subjects were interviewed. Women exposed to electrical transmission installations showed elevated risks (OR 5.81, 95% CI 1.72 to 19.66). Positive associations with exposure to control rooms were seen among men and women, but most risk increases were restricted to subjects with dark iris colour. Application of published EMF measurements revealed stronger risk increases among women compared to men. Again, elevated risks were restricted to subjects with dark eye colour. Although based on a low prevalence of exposure to potential occupational sources of EMF, our data indicate that exposed dark-eyed women may be at particular risk for uveal melanoma.

  10. Going Large or Going Small in Plant Design: Comparison between a P.P. with three small Kaplan turbines and a P.P. with just one Large Kaplan turbine

    NASA Astrophysics Data System (ADS)

    Castro-Otero, C.

    2017-04-01

    Very often small turbine manufacturers are requested to produce sizeable turbines, too large in terms of physical dimensions, power or designing capacity. In these cases clever alternative solutions should be found to meet customers’ needs. For instance: in the old times twin runner Francis turbines were an option instead of one large machine, or if a too large Pelton turbine cannot be manufactured or designed, a good option is to install a medium size Francis and a small Pelton. Likewise, a similar approach needs to be taken should the manufacturer be asked for a too large Kaplan. Facing this situation a good option is to install three or more small Kaplan turbines. This particular case was studied in depth and after all the considerations had been made, the following question arouse: Is this a way out for the manufacturer or is it really the best option for the customer? The choice made as a way out for the manufacturer became the best option for the customer and a success for both parties. This paper aims to encourage developers and engineering firms to search for more options than the traditional one to find the best option in plant design.

  11. Handbook of experiences in the design and installation of solar heating and cooling systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ward, D.S.; Oberoi, H.S.

    1980-07-01

    A large array of problems encountered are detailed, including design errors, installation mistakes, cases of inadequate durability of materials and unacceptable reliability of components, and wide variations in the performance and operation of different solar systems. Durability, reliability, and design problems are reviewed for solar collector subsystems, heat transfer fluids, thermal storage, passive solar components, piping/ducting, and reliability/operational problems. The following performance topics are covered: criteria for design and performance analysis, domestic hot water systems, passive space heating systems, active space heating systems, space cooling systems, analysis of systems performance, and performance evaluations. (MHR)

  12. NanTroSEIZE observatories: Installation of a long-term borehole monitoring systems offshore the Kii Peninsula, Japan

    NASA Astrophysics Data System (ADS)

    Kopf, A.; Saffer, D. M.; Davis, E. E.; Araki, E.; Kinoshita, M.; Lauer, R. M.; Wheat, C. G.; Kitada, K.; Kimura, T.; Toczko, S.; Eguchi, N. O.; Science Parties, E.

    2010-12-01

    The IODP Nankai Trough Seismogenic Zone Experiment (NanTroSEIZE) is a multi-expedition drilling program designed to investigate fault mechanics, fault slip behavior, and strain accumulation along subduction megathrusts, through coring, logging, and long-term monitoring experiments. One key objective is the development and installation of a borehole observatory network extending from locations above the outer, presumably aseismic accretionary wedge to the seismogenic and interseismically locked plate interface, to record seismicity and slip transients, monitor strain accumulation, document hydraulic transients associated with deformation events, and quantify in situ pore fluid pressure and temperature. As part of recent NanTroSEIZE operations, borehole instruments have been developed for deployment at two sites: (1) Site C0010, which penetrates a major out-of-sequence thrust fault termed the “megasplay” at ca. 400 mbsf, and (2) Site C0002 in the Kumano forearc basin at a location that overlies both the updip edge of the inferred interseismically locked portion of the plate interface, and clusters of very low frequency thrust and reverse earthquakes located within the accretionary prism and potentially on the megasplay fault. In 2009, Site C0010 was drilled and cased with screens to access the megasplay fault, and a simple pore pressure and temperature monitoring system (a ”smartplug”) was installed. The simple observatory unit includes pressure and temperature sensors and a data logging package mounted beneath a mechanically set retrievable casing packer, and includes two pressure sensors, one in hydraulic communication with the formation through the casing screens below the packer, and the other to the open borehole above the packer to record hydrostatic reference pressure and ocean loading signals. Temperatures are recorded within the instrument package using a platinum thermometer and by a self-contained miniature temperature logger (MTL). In fall 2010, the smartplug will be retrieved and replaced with an upgraded instrument package that also includes an autonomous osmotic geochemical sampling system and microbial colonization experiment. Fall 2010 operations will also drill and case Site C0002 to ca. 1000 m depth and install a newly developed multi-sensor permanent observatory system, which includes a volumetric strainmeter, a broadband seismometer, tiltmeter, thermister string, and multi-level pore-pressure sensors. The strain, seismometer, and tilt sensors will be cemented with the basal mudstones of the Kumano basin, and pore pressure will be monitored within both the underlying accretionary prism and within the lower basin sediments. The observatory will ultimately be connected to the seafloor fiber-optic cable network DONET. Here, we report on the retrieval of the smartplug, installation and configuration of the new multi-sensor permanent observatory, and preliminary data obtained from the smartplug deployment.

  13. Air Force Smart Bases

    DTIC Science & Technology

    2017-10-19

    the future. Then to design an information and data architecture to enable many use cases for further mission experimentation and acquisition strategy...development. A key feature of the future of smart cities (or, in our case , smart bases) is that citizen engagement with one another and with their...cybersecurity on Air Force installations. Participants The design sprint brought in over 30 participants from across the military and industry

  14. 26 CFR 1.453-9 - Gain or loss on disposition of installment obligations.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) the amount realized, in the case of satisfaction at other than face value or in the case of a sale or... the face value of the obligation over an amount equal to the income which would be returnable were the.... Face value of notes 15,000 Amount of income returnable were the notes satisfied in full, 50 percent of...

  15. 26 CFR 1.453-9 - Gain or loss on disposition of installment obligations.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) the amount realized, in the case of satisfaction at other than face value or in the case of a sale or... the face value of the obligation over an amount equal to the income which would be returnable were the.... Face value of notes 15,000 Amount of income returnable were the notes satisfied in full, 50 percent of...

  16. 26 CFR 1.453-9 - Gain or loss on disposition of installment obligations.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) the amount realized, in the case of satisfaction at other than face value or in the case of a sale or... the face value of the obligation over an amount equal to the income which would be returnable were the.... Face value of notes 15,000 Amount of income returnable were the notes satisfied in full, 50 percent of...

  17. 26 CFR 1.453-9 - Gain or loss on disposition of installment obligations.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) the amount realized, in the case of satisfaction at other than face value or in the case of a sale or... the face value of the obligation over an amount equal to the income which would be returnable were the.... Face value of notes 15,000 Amount of income returnable were the notes satisfied in full, 50 percent of...

  18. 26 CFR 1.453-9 - Gain or loss on disposition of installment obligations.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) the amount realized, in the case of satisfaction at other than face value or in the case of a sale or... the face value of the obligation over an amount equal to the income which would be returnable were the.... Face value of notes 15,000 Amount of income returnable were the notes satisfied in full, 50 percent of...

  19. Environmental management framework for wind farm siting: methodology and case study.

    PubMed

    Tegou, Leda-Ioanna; Polatidis, Heracles; Haralambopoulos, Dias A

    2010-11-01

    This paper develops an integrated framework to evaluate land suitability for wind farm siting that combines multi-criteria analysis (MCA) with geographical information systems (GIS); an application of the proposed framework for the island of Lesvos, Greece, is further illustrated. A set of environmental, economic, social, and technical constraints, based on recent Greek legislation, identifies the potential sites for wind power installation. Furthermore, the area under consideration is evaluated by a variety of criteria, such as wind power potential, land cover type, electricity demand, visual impact, land value, and distance from the electricity grid. The pair-wise comparison method in the context of the analytic hierarchy process (AHP) is applied to estimate the criteria weights in order to establish their relative importance in site evaluation. The overall suitability of the study region for wind farm siting is appraised through the weighted summation rule. Results showed that only a very small percentage of the total area of Lesvos could be suitable for wind farm installation, although favourable wind potential exists in many more areas of the island. Copyright 2010 Elsevier Ltd. All rights reserved.

  20. Real-time monitoring of methanol concentration using a shear horizontal surface acoustic wave sensor for direct methanol fuel cell without reference liquid measurement

    NASA Astrophysics Data System (ADS)

    Tada, Kyosuke; Nozawa, Takuya; Kondoh, Jun

    2017-07-01

    In recent years, there has been an increasing demand for sensors that continuously measure liquid concentrations and detect abnormalities in liquid environments. In this study, a shear horizontal surface acoustic wave (SH-SAW) sensor is applied for the continuous monitoring of liquid concentrations. As the SH-SAW sensor functions using the relative measurement method, it normally needs a reference at each measurement. However, if the sensor is installed in a liquid flow cell, it is difficult to measure a reference liquid. Therefore, it is important to establish an estimation method for liquid concentrations using the SH-SAW sensor without requiring a reference measurement. In this study, the SH-SAW sensor is installed in a direct methanol fuel cell to monitor the methanol concentration. The estimated concentration is compared with a conventional density meter. Moreover, the effect of formic acid is examined. When the fuel temperature is higher than 70 °C, it is necessary to consider the influence of liquid conductivity. Here, an estimation method for these cases is also proposed.

  1. DOE/NREL supported wind energy activities in Indonesia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drouilhet, S.

    1997-12-01

    This paper describes three wind energy related projects which are underway in Indonesia. The first is a USAID/Winrock Wind for Island and Nongovernmental Development (WIND) project. The objectives of this project are to train local nongovernmental organizations (NGOs) in the siting, installation, operation, and maintenance of small wind turbines. Then to install up to 20 wind systems to provide electric power for productive end uses while creating micro-enterprises which will generate enough revenue to sustain the wind energy systems. The second project is a joint Community Power Corporation/PLN (Indonesian National Electric Utility) case study of hybrid power systems in villagemore » settings. The objective is to evaluate the economic viability of various hybrid power options for several different situations involving wind/photovoltaics/batteries/diesel. The third project is a World Bank/PLN preliminary market assessment for wind/diesel hybrid systems. The objective is to estimate the size of the total potential market for wind/diesel hybrid power systems in Indonesia. The study will examine both wind retrofits to existing diesel mini-grids and new wind-diesel plants in currently unelectrified villages.« less

  2. Design considerations in clustering nuclear rocket engines

    NASA Technical Reports Server (NTRS)

    Sager, Paul H.

    1992-01-01

    An initial investigation of the design considerations in clustering nuclear rocket engines for space transfer vehicles has been made. The clustering of both propulsion modules (which include start tanks) and nuclear rocket engines installed directly to a vehicle core tank appears to be feasible. Special provisions to shield opposite run tanks and the opposite side of a core tank - in the case of the boost pump concept - are required; the installation of a circumferential reactor side shield sector appears to provide an effective solution to this problem. While the time response to an engine-out event does not appear to be critical, the gimbal displacement required appears to be important. Since an installation of three engines offers a substantial reduction in gimbal requirements for engine-out and it may be possible to further enhance mission reliability with the greater number of engines, it is recommended that a cluster of four engines be considered.

  3. Statistical analysis of electromagnetic radiation measurements in the vicinity of indoor microcell GSM/UMTS base stations in Serbia.

    PubMed

    Koprivica, Mladen; Petrić, Majda; Nešković, Nataša; Nešković, Aleksandar

    2016-01-01

    To determine the level of radiofrequency radiation generated by base stations of Global System for Mobile Communications and Universal Mobile Telecommunication System, extensive electromagnetic field strength measurements were carried out in the vicinity of 664 base station locations. These were classified into three categories: indoor, masts, and locations with installations on buildings. Although microcell base stations with antennas installed indoors typically emit less power than outdoor macrocell base stations, the fact that people can be found close to antennas requires exposure originating from these base stations to be carefully considered. Measurement results showed that maximum recorded value of electric field strength exceeded International Commission on Non-Ionizing Radiation Protection reference levels at 7% of indoor base station locations. At the same time, this percentage was much lower in the case of masts and installations on buildings (0% and 2.5%, respectively). © 2015 Wiley Periodicals, Inc.

  4. Design considerations in clustering nuclear rocket engines

    NASA Astrophysics Data System (ADS)

    Sager, Paul H.

    1992-07-01

    An initial investigation of the design considerations in clustering nuclear rocket engines for space transfer vehicles has been made. The clustering of both propulsion modules (which include start tanks) and nuclear rocket engines installed directly to a vehicle core tank appears to be feasible. Special provisions to shield opposite run tanks and the opposite side of a core tank - in the case of the boost pump concept - are required; the installation of a circumferential reactor side shield sector appears to provide an effective solution to this problem. While the time response to an engine-out event does not appear to be critical, the gimbal displacement required appears to be important. Since an installation of three engines offers a substantial reduction in gimbal requirements for engine-out and it may be possible to further enhance mission reliability with the greater number of engines, it is recommended that a cluster of four engines be considered.

  5. Performance and Economic Modeling of Horizontally Drilled Ground-Source Heat Pumps in Select California Climates

    NASA Astrophysics Data System (ADS)

    Wiryadinata, Steven

    Service life modeling was performed to gage the viability of unitary 3.5 kWt, ground-source terminal heat pumps (GTHP) employing horizontal directionally drilled geothermal heat exchangers (GHX) over air-source terminal heat pumps (PTHP) in hotels and motels and residential apartment building sectors in California's coastal and inland climates. Results suggest the GTHP can reduce hourly peak demand for the utility by 7%-25% compared to PTHP, depending on the climate and building type. The annual energy savings, which range from -1% to 5%, are highly dependent on the GTHP pump energy use relative to the energy savings attributed to the difference in ground and air temperatures (DeltaT). In mild climates with small ?T, the pump energy use may overcome any advantage to utilizing a GHX. The majority of total levelized cost savings - ranging from 0.18/ft2 to 0.3/ft 2 - are due to reduced maintenance and lifetime capital cost normally associated with geothermal heat pump systems. Without these reductions (not validated for the GTHP system studied), the GTHP technology does not appear to offer significant advantages over PTHP in the climate zones studied here. The GTHP levelized cost was most sensitive to variations in installed cost and in some cases, energy use (influenced by climate zone choice), which together highlights the importance of climate selection for installation, and the need for larger market penetration of ground-source systems in order to bring down installed costs as the technology matures.

  6. Installation-Wide Energy Conservation Demonstration at Fort McClellan, Alabama

    DTIC Science & Technology

    1988-11-01

    Inefficient Electrical Motors 12 Dispensary Chiller Installation 12 Combustion Optimization of Gas-fired Heating Equipment 12 Infiltration Study of Family... Chiller Installation 34 5 FAMILY HOUSING .................................................... 37 Combustion Optimization of Gas-fired Heating...in Outdoor Air Ventilation 59 Replacement of Inefficient Electric Motors 59 Dispensary Chiller Installation 60 Combustion Optimization of Gas-fired

  7. 40 CFR 89.413 - Raw sampling procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... emissions. (a) The gaseous emission sampling probe must be installed at least 0.5 m or 3 times the diameter... the case of a multi-cylinder engine with a branched exhaust manifold, the inlet of the probe shall be...

  8. 40 CFR 89.413 - Raw sampling procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... emissions. (a) The gaseous emission sampling probe must be installed at least 0.5 m or 3 times the diameter... the case of a multi-cylinder engine with a branched exhaust manifold, the inlet of the probe shall be...

  9. Before you install exterior wood-based siding

    Treesearch

    Mark T. Knaebe

    1995-01-01

    Moisture accumulation and extreme fluctuations in moisture levels can adversely affect the service life of components, such as wood siding and windows. Adverse moisture conditions can induce checking, warping, paint failure, and in severe cases, rotting of the wood.

  10. Permanent installation of fibre-optic DTS cables in boreholes for temperature monitoring

    NASA Astrophysics Data System (ADS)

    Henninges, J.; Schrötter, J.; Erbas, K.; Böde, S.; Huenges, E.

    2003-04-01

    Temperature measurements have become an important tool for the monitoring of dynamic processes in the subsurface both in academia and industry. An innovative experimental design for the monitoring of spatial and temporal variations of temperature along boreholes was developed and successfully applied under extreme arctic conditions during a field experiment, which was carried out within the framework of the Mallik 2002 Production Research Well Program*. Three 40 m spaced, 1200 m deep wells were equipped with permanent fibre-optic sensor cables and the variation of temperature was measured deploying the Distributed Temperature Sensing (DTS) technology. The used DTS system enables the simultaneous online registration of temperature profiles along the three boreholes with a maximum spatial resolution of 0.25 m and a minimum sampling interval of 7 sec. After an individual calibration of the fibre-optic sensor cables a resolution of 0.3 °C of the measured temperature data could be achieved. A special feature of the experiment design is the installation of the sensor cables outside the borehole casing. The fibre-optic cables were attached to the outer side of the casing at every connector within intervals of approx. 12 m with cable clamps. The clamps enable a defined positioning of the cable around the perimeter of the casing and are protecting the cable from mechanical damage during installation. After completion the sensor cables are located in the cement annulus between casing and borehole wall. As an example of the performance of the described temperature logging technology data from the reaming of a 300 m thick cement plug inside the borehole is displayed, offering a unique opportunity to explore thermal processes in the near vicinity of a borehole during drilling. The temperature changes image the progress of the drill bit as well as changes in the mud circulation. Furthermore, local effects can be observed that relate to local thermal properties and technical features of the cable installation. (*) The program participants include 8 partners; The Geological Survey of Canada (GSC), The Japan National Oil Corporation (JNOC), GeoForschungsZentrum Potsdam (GFZ), United States Geological Survey (USGS), United States Department of the Energy (USDOE), India Ministry of Petroleum and Natural Gas (MOPNG)/Gas Authority of India (GAIL) and the Chevron-BP-Burlington joint venture group.

  11. Testing various modes of installation for permanent broadband stations in open field environment

    NASA Astrophysics Data System (ADS)

    Vergne, Jérôme; Charade, Olivier; Arnold, Benoît; Louis-Xavier, Thierry

    2014-05-01

    In the framework of the RESIF (Réseau Sismologique et géodésique Français) project, we plan to install more than one hundred new permanent broadband stations in metropolitan France within the next 6 years. Whenever possible, the sensors will be installed in natural or artificial underground cavities that provide a stable thermal environment. However such places do not exist everywhere and we expect that about half the future stations will have to be set up in open fields. For such sites, we are thus looking for a standard model of hosting infrastructure for the sensors that would be easily replicated and would provide good noise level performances at long periods. Since early 2013, we have been operating a prototype station at Clévilliers, a small location in the sedimentary Beauce plain, where we test three kinds of buried seismic vaults and a down-hole installation. The cylindrical seismic vaults are 3m deep and 1m wide and only differ by the type of coupling between the casing and the concrete slab where we installed insulated Trillium T120PA seismometers. The down-hole installation consists in a 3m deep well hosting a Trillium Posthole seismometer. For reference, another sensor has been installed in a ~50cm deep hole, similarly to the way we test every new potential site. Here we compare the noise level in each infrastructure at different frequencies. We observe quite similar performances for the vertical component recorded in the different wells. Conversely, the noise levels on the horizontal components at periods greater than 10s vary by more than 20dB depending on the installation condition. The best results are obtained in the completely decoupled vault and for the down-hole setting, both showing performances comparable to some of our permanent stations installed in tunnels. The amplitude of the horizontal noise also appears to be highly correlated to wind speed recorded on site, even at long periods. The variable response of each vault to such external forcing can partly explain the variations of the seismic noise levels.

  12. United States Air Force 611th Air Support Group/Civil Engineering Squadron Elmendorf AFB, Alaska. Remedial investigation and feasibility study. Bullen Point Radar Installation, Alaska. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karmi, S.

    1996-03-18

    The United States Air Force (Air Force) has prepared this Remedial investigation/Feasibility Study (RI/FS) report as part of the Installation Restoration Program (IRP) to present results of RI/FS activities at five sites at the Bullen Point radar installation. The IRP provides for investigating, quantifying, and remediating environmental contamination from past waste management activities at Air Force installations throughout the United States.

  13. Cost of installing and operating an electronic clinical decision support system for maternal health care: case of Tanzania rural primary health centres.

    PubMed

    Saronga, Happiness Pius; Dalaba, Maxwell Ayindenaba; Dong, Hengjin; Leshabari, Melkizedeck; Sauerborn, Rainer; Sukums, Felix; Blank, Antje; Kaltschmidt, Jens; Loukanova, Svetla

    2015-04-02

    Poor quality of care is among the causes of high maternal and newborn disease burden in Tanzania. Potential reason for poor quality of care is the existence of a "know-do gap" where by health workers do not perform to the best of their knowledge. An electronic clinical decision support system (CDSS) for maternal health care was piloted in six rural primary health centers of Tanzania to improve performance of health workers by facilitating adherence to World Health Organization (WHO) guidelines and ultimately improve quality of maternal health care. This study aimed at assessing the cost of installing and operating the system in the health centers. This retrospective study was conducted in Lindi, Tanzania. Costs incurred by the project were analyzed using Ingredients approach. These costs broadly included vehicle, computers, furniture, facility, CDSS software, transport, personnel, training, supplies and communication. These were grouped into installation and operation cost; recurrent and capital cost; and fixed and variable cost. We assessed the CDSS in terms of its financial and economic cost implications. We also conducted a sensitivity analysis on the estimations. Total financial cost of CDSS intervention amounted to 185,927.78 USD. 77% of these costs were incurred in the installation phase and included all the activities in preparation for the actual operation of the system for client care. Generally, training made the largest share of costs (33% of total cost and more than half of the recurrent cost) followed by CDSS software- 32% of total cost. There was a difference of 31.4% between the economic and financial costs. 92.5% of economic costs were fixed costs consisting of inputs whose costs do not vary with the volume of activity within a given range. Economic cost per CDSS contact was 52.7 USD but sensitive to discount rate, asset useful life and input cost variations. Our study presents financial and economic cost estimates of installing and operating an electronic CDSS for maternal health care in six rural health centres. From these findings one can understand exactly what goes into a similar investment and thus determine sorts of input modification needed to fit their context.

  14. Building America Case Study: Control Retrofits for Multifamily Domestic Hot Water Recirculation Systems, Brooklyn, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperaturemore » modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7 percent after implementing the demand control technique, 2 percent after implementing temperature modulation, and 15 percent after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8 percent, 1 percent, and 14 percent for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.« less

  15. Building America Case Study: Control Retrofits for Multifamily Domestic Hot Water Recirculation Systems, Brooklyn, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Dentz; E. Ansanelli, H. Henderson, Jr.; K. Varshney

    Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperaturemore » modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7% after implementing the demand control technique, 2% after implementing temperature modulation, and 15% after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8%, 1%, and 14% for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.« less

  16. The Effects of Market Concentration on Residential Solar PV Prices: Competition, Installer Scale, and Soft Costs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    OShaughnessy, Eric J

    Competition among residential solar photovoltaic (PV) installers may reduce PV price markups and yield lower prices. At the same time, competition may reduce installer experience and opportunities for cost reductions through learning-by-doing and economies of scale. These dynamics suggest that PV non-hardware or 'soft' costs and installed prices depend on the distribution of market shares among installers, also known as market concentration. This study leverages a rich data set of 226,769 residential PV systems to examine the relationship between market concentration, soft costs, and PV prices. The results show that PV prices are lower, on average, in more concentrated markets,more » i.e., markets with fewer installers or where few installers hold high market share. The study provides evidence that this relationship is non-linear, such that prices are minimized in markets with an optimal balance of the benefits of market concentration and the benefits of competition.« less

  17. Performance of buried pipe installation.

    DOT National Transportation Integrated Search

    2010-05-01

    The purpose of this study is to determine the effects of geometric and mechanical parameters : characterizing the soil structure interaction developed in a buried pipe installation located under : roads/highways. The drainage pipes or culverts instal...

  18. Core-collapse SNe of type IIP and their progenitors: The case study of PNV J01315945+3328458

    NASA Astrophysics Data System (ADS)

    Dastidar, Raya; Kumar, Brijesh; Sahu, Devendra Kumar; Misra, Kuntal; Singh, Mridweeka; Gangopadhyay, Anjasha; Anapuma, Gadiyara Chakrapani; Pandey, Shashi Bhushan

    2018-04-01

    The type II supernovae (SNe) are hydrogen-rich cosmic explosions resulting from the collapse of massive stars. The impetus of studying individual events arises from its cosmological importance and the diverse understanding of the evolution and explosion mechanism of such events. In this work, we present the preliminary photometric and spectroscopic analysis of a recent type IIP explosion, PNV J01315945+3328458 in the galaxy NGC 582. While the initial phases of these energetic events are bright enough to be observed with the 1-2m class telescopes, the supernovae fade below the detection limit of these telescopes in the nebular phase. In addition, the class of sub-luminous events with Mv ˜ -15 or the events occurring at higher redshift, fade below the detection limit of these telescopes very early in their evolution. Large aperture telescopes like the newly installed 3.6m Devasthal Optical Telescope (DOT) will ensure a longer coverage of such events and also to probe deeper into the Universe. With the 3.6m telescope installed in Devasthal (DOT), we plan to study the progenitor environment of CCSNe to infer the metallicity at the explosion site.

  19. Performance of Subsurface Tube Drainage System in Saline Soils: A Case Study

    NASA Astrophysics Data System (ADS)

    Pali, A. K.

    2015-06-01

    In order to improve the saline and water logged soils caused due to groundwater table rise, installation of subsurface drainage system is considered as one of the best remedies. However, the design of the drainage system has to be accurate so that the field performance results conform to the designed results. In this investigation, the field performance of subsurface tube drainage system installed at the study area was evaluated. The performance was evaluated on the basis of comparison of the designed value of water table drop as 30 cm after 2 days of drainage and predicted and field measured hydraulic heads for a consecutive drainage period of 14 days. The investigation revealed that the actual drop of water table after 2 days of drainage was 25 cm, about 17 % less than the designed value of 30 cm after 2 days of drainage. The comparison of hydraulic heads predicted by Van Schilfgaarde equation of unsteady drainage with the field-measured hydraulic heads showed that the deviation of predicted hydraulic heads varied within a range of ±8 % indicating high acceptability of Van Schlifgaarde equation for designing subsurface drainage system in saline and water logged soils resembling to that of the study area.

  20. Influence of matrix attachment installation load on movement and resultant forces in implant overdentures.

    PubMed

    Goto, Takaharu; Nagao, Kan; Ishida, Yuichi; Tomotake, Yoritoki; Ichikawa, Tetsuo

    2015-02-01

    This in vitro study investigated the effect of attachment installation conditions on the load transfer and denture movements of implant overdentures, and aims to clarify the differences among the three types of attachments, namely ball, Locator, and magnet attachments. Three types of attachments, namely ball, Locator, and magnetic attachments were used. An acrylic resin mandibular edentulous model with two implants placed in the bilateral canine regions and removable overdenture were prepared. The two implants and bilateral molar ridges were connected to three-axis load-cell transducers, and a universal testing machine was used to apply a 50 N vertical force to each site of the occlusal table in the first molar region. The denture movement was measured using a G(2) motion sensor. Three installation conditions, namely, the application of 0, 50, and 100 N loads were used to install each attachment on the denture base. The load transfer and denture movement were then evaluated. The resultant force decreased with increasing installation load for all attachments. In particular, the resultant force on implants on the loading side of the Locator attachment significantly decreased when the installation load was increased from 0 to 50 N, and that for magnetic attachment significantly decreased when the installation load was increased from 50 to 100 N. For the residual ridges on the loading side, the direction of the forces for all attachments changed to downward with increasing installation load. Furthermore, the yaw Euler angle increased with increasing installation load for the magnetic attachment. Subject to the limitations of this study, the use of any installation load greater than 0 N is recommended for the installation of ball and Locator attachments on a denture base. Regarding magnetic attachments, our results also recommend installation on a denture base using any installation load greater than 0 N, and suggest that the resultant force acting on the implant can be decreased by increasing the installation load; however, a large installation load of 100 N should be avoided when installing the attachment on the denture base to avoid increasing the denture movement. © 2014 by the American College of Prosthodontists.

  1. Energy from wood waste - A case study

    NASA Technical Reports Server (NTRS)

    Scola, R.; Daughtrey, K.

    1980-01-01

    A joint study has been conducted by NASA and Army installations collocated in a dense forest in southwestern Mississippi in order to determine the technical and economic feasibility of using wood waste as a renewable energy source. The study has shown that, with proper forest management, the timber on government lands could eventually support the total energy requirements of 832 billion Btu/yr. Analysis of the current conversion technologies indicates that the direct combustion spreader stoker approach is the best demonstrated technology for this specific application. The economics of the individual powerplants reveal them as attractive alternatives to fossil fueled plants. Environmental aspects are also discussed.

  2. Social Media Participation in Urban Planning: a New way to Interact and Take Decisions

    NASA Astrophysics Data System (ADS)

    López-Ornelas, E.; Abascal-Mena, R.; Zepeda-Hernández, S.

    2017-09-01

    Social Media Participation can be very important when you have to make an important decision about a topic related to urban planning. Textual analysis to identify the sentiment about a topic or, community detection and user analysis to identify the actors involved on a discussion can be very important for the persons or institutions that have to take an important decision. In this paper we propose a methodological design to analyse participation in social media. We study the installation of a new airport in Mexico City as a case of study to highlight the importance of conducting a study of this nature.

  3. Integrating Photovoltaic Systems into Low-Income Housing Developments: A Case Study on the Creation of a New Residential Financing Model and Low-Income Resident Job Training Program, September 2011 (Brochure)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dean, J.; Smith-Dreier, C.; Mekonnen, G.

    2011-09-01

    This case study covers the process of successfully integrating photovoltaic (PV) systems into a low-income housing development in northeast Denver, Colorado, focusing specifically on a new financing model and job training. The Northeast Denver Housing Center (NDHC), working in cooperation with Del Norte Neighborhood Development Corporation, Groundwork Denver, and the National Renewable Energy Laboratory (NREL), was able to finance the PV system installations by blending private equity funding with utility rebates, federal tax credits, and public sector funding. A grant provided by the Governor's Energy Office allowed for the creation of the new financing model. In addition, the program incorporatedmore » an innovative low-income job training program and an energy conservation incentive program.« less

  4. Practical Applications of a Building Method to Construct Aerodynamic Database of Guided Missile Using Wind Tunnel Test Data

    NASA Astrophysics Data System (ADS)

    Kim, Duk-hyun; Lee, Hyoung-Jin

    2018-04-01

    A study of efficient aerodynamic database modeling method was conducted. A creation of database using periodicity and symmetry characteristic of missile aerodynamic coefficient was investigated to minimize the number of wind tunnel test cases. In addition, studies of how to generate the aerodynamic database when the periodicity changes due to installation of protuberance and how to conduct a zero calibration were carried out. Depending on missile configurations, the required number of test cases changes and there exist tests that can be omitted. A database of aerodynamic on deflection angle of control surface can be constituted using phase shift. A validity of modeling method was demonstrated by confirming that the result which the aerodynamic coefficient calculated by using the modeling method was in agreement with wind tunnel test results.

  5. Visual Privacy by Context: Proposal and Evaluation of a Level-Based Visualisation Scheme

    PubMed Central

    Padilla-López, José Ramón; Chaaraoui, Alexandros Andre; Gu, Feng; Flórez-Revuelta, Francisco

    2015-01-01

    Privacy in image and video data has become an important subject since cameras are being installed in an increasing number of public and private spaces. Specifically, in assisted living, intelligent monitoring based on computer vision can allow one to provide risk detection and support services that increase people's autonomy at home. In the present work, a level-based visualisation scheme is proposed to provide visual privacy when human intervention is necessary, such as at telerehabilitation and safety assessment applications. Visualisation levels are dynamically selected based on the previously modelled context. In this way, different levels of protection can be provided, maintaining the necessary intelligibility required for the applications. Furthermore, a case study of a living room, where a top-view camera is installed, is presented. Finally, the performed survey-based evaluation indicates the degree of protection provided by the different visualisation models, as well as the personal privacy preferences and valuations of the users. PMID:26053746

  6. Household food waste separation behavior and the importance of convenience.

    PubMed

    Bernstad, Anna

    2014-07-01

    Two different strategies aiming at increasing household source-separation of food waste were assessed through a case-study in a Swedish residential area (a) use of written information, distributed as leaflets amongst households and (b) installation of equipment for source-segregation of waste with the aim of increasing convenience food waste sorting in kitchens. Weightings of separately collected food waste before and after distribution of written information suggest that this resulted in neither a significant increased amount of separately collected food waste, nor an increased source-separation ratio. After installation of sorting equipment in households, both the amount of separately collected food waste as well as the source-separation ratio increased vastly. Long-term monitoring shows that results where longstanding. Results emphasize the importance of convenience and existence of infrastructure necessary for source-segregation of waste as important factors for household waste recycling, but also highlight the need of addressing these aspects where waste is generated, i.e. already inside the household. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. [The profile urological emergencies at the Conakry University Teaching Hospital, Guinea].

    PubMed

    Bobo Diallo, A; Bah, I; Diallo, T M O; Bah, O R; Amougou, B; Bah, M D; Guirassy, S; Bobo Diallo, M

    2010-03-01

    To stick out the profile urological emergencies at the Conakry University Teaching Hospital, Guinea. This retrospective study, carried out over a period of 3 years (January 2005-December 2007), included 757 urological emergencies admitted to the urology department of the university hospital of Conakry, Guinea. The mean age of patients was 56 years. These patients had an age equal to or higher than 60 years in 58% of the cases. The sex ratio (M/F) was 16.6. According to the social profession, the farmer (40,6%) and workers (21%) were the dominant patients. The most frequent illness was vesical urinary retention (73.9%), hematuria (9.6%) and genito-urinary system trauma (7%). The most performed procedures were the installation of a urethral catheter (55.25%) and the installation of a suprapubic catheter (24.14%). The most frequent urological emergency in our country was vesical urinary retention, the hematuria and genito-urinary system trauma are not rare there. Copyright 2009 Elsevier Masson SAS. All rights reserved.

  8. Energy and economic analysis of the carbon dioxide capture installation with the use of monoethanolamine and ammonia

    NASA Astrophysics Data System (ADS)

    Bochon, Krzysztof; Chmielniak, Tadeusz

    2015-03-01

    In the study an accurate energy and economic analysis of the carbon capture installation was carried out. Chemical absorption with the use of monoethanolamine (MEA) and ammonia was adopted as the technology of carbon dioxide (CO2) capture from flue gases. The energy analysis was performed using a commercial software package to analyze the chemical processes. In the case of MEA, the demand for regeneration heat was about 3.5 MJ/kg of CO2, whereas for ammonia it totalled 2 MJ/kg CO2. The economic analysis was based on the net present value (NPV) method. The limit price for CO2 emissions allowances at which the investment project becomes profitable (NPV = 0) was more than 160 PLN/Mg for MEA and less than 150 PLN/Mg for ammonia. A sensitivity analysis was also carried out to determine the limit price of CO2 emissions allowances depending on electricity generation costs at different values of investment expenditures.

  9. GIS-based planning system for managing the flow of construction and demolition waste in Brazil.

    PubMed

    Paz, Diogo Henrique Fernandes da; Lafayette, Kalinny Patrícia Vaz; Sobral, Maria do Carmo

    2018-05-01

    The objective of this article was to plan a network for municipal management of construction and demolition waste in Brazil with the assistance of a geographic information system, using the city of Recife as a case study. The methodology was carried out in three stages. The first was to map the illegal construction and demolition of waste disposal points across Recife and classify the waste according to its recyclability. In sequence, a method for indicating suitable areas for installation of voluntary delivery points, for small waste generators, are presented. Finally, a method for indicating suitable areas for the installation of trans-shipment and waste sorting areas, developed for large generators, is presented. The results show that a geographic information system is an essential tool in the planning of municipal construction and demolition waste management, in order to facilitate the spatial analysis and control the generation, sorting, collection, transportation, and final destination of construction and demolition waste, increasing the rate of recovery and recycling of materials.

  10. 29 CFR 785.24 - Principles noted in Portal-to-Portal Bulletin.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... his machine, or install a new cutting tool. Such activities are an integral part of the principal activity, and are included within such term. (2) In the case of a garment worker in a textile mill, who is...

  11. Hybrid Laser/GMAW of High Strength Steel Gas Transmission Pipelines

    DOT National Transportation Integrated Search

    2008-07-01

    Pipelines will be an integral part of our energy distribution systems for the foreseeable future. Operators are currently considering the installation of tens of billions of dollars of pipeline infrastructure. In a number of cases, the cost of export...

  12. Solar energy for process heat: Design/cost studies of four industrial retrofit applications

    NASA Technical Reports Server (NTRS)

    French, R. L.; Bartera, R. E.

    1978-01-01

    Five specific California plants with potentially attractive solar applications were identified in a process heat survey. These five plants were visited, process requirements evaluated, and conceptual solar system designs were generated. Four DOE (ERDA) sponsored solar energy system demonstration projects were also reviewed and compared to the design/cost cases included in this report. In four of the five cases investigated, retrofit installations providing significant amounts of thermal energy were found to be feasible. The fifth was rejected because of the condition of the building involved, but the process (soap making) appears to be an attractive potential solar application. Costs, however, tend to be high. Several potential areas for cost reduction were identified including larger collector modules and higher duty cycles.

  13. Performance evaluation of buried pipe installation.

    DOT National Transportation Integrated Search

    2010-05-01

    The purpose of this study is to determine the effects of geometric and mechanical parameters characterizing the soil structure interaction developed in a buried pipe installation located under roads/highways. The drainage pipes or culverts installed ...

  14. Levels-of-growing-stock cooperative study in Douglas-fir: report no. 18--Rocky Brook, 1963-2006.

    Treesearch

    Robert O. Curtis; David D. Marshall

    2009-01-01

    This report documents the history and results of the Rocky Brook installation of the cooperative levels-of-growing-stock (LOGS) study in Douglas-fir (Pseudotsuga menziesii (Mirb.) Franco), over the 41-year period 1965 to 2006. This 1938 plantation is one of the two site-IV installations among the nine installations in the study. Much public...

  15. Evaluation of appropriate system for reclaimed wastewater reuse in each area of Tokyo using GIS-based water balance model.

    PubMed

    Aramaki, T; Sugimoto, R; Hanaki, K; Matsuo, T

    2001-01-01

    The appropriate type of reclaimed wastewater reuse system in each area of Tokyo was evaluated from the aspect of economic efficiency, using a GIS-based water balances model. The following four reclaimed wastewater reuse systems and conventional waterworks and sewerage system were evaluated; "Rain water storage and use system", "Onsite wastewater treatment and reuse system", "Sewage treatment and reuse at an intermediate point on the sewer pipe" and "Treated water supply system in sewage treatment plant". In the case that we install them to office and residential buildings, the supplied volume by reclaimed wastewater reuse systems is 693 thousands m3/d, this corresponds to 15% of total water demand in the area. Furthermore, the effects of the following scenarios brought about by technological innovation in water treatment were investigated; the case that flush water in toilet and wastewater from kitchen are also available as source in a "onsite wastewater treatment and reuse system" and the case that reclaimed water is used for laundering in residential buildings. When reclaimed water is used for laundering in residential buildings, the supplied volume by these systems increases to 814 thousand m3/d in the case that these systems are installed to office and residential buildings.

  16. Program design for incentivizing ignition interlock installation for alcohol-impaired drivers: The Ontario approach.

    PubMed

    Ma, Tracey; Byrne, Patrick A; Bhatti, Junaid A; Elzohairy, Yoassry

    2016-10-01

    Drinking and driving is a major risk factor for traffic injuries. Although ignition interlocks reduce drinking and driving while installed, several issues undermine their implementation including delayed eligibility for installation, low installation once eligible, and a return to previous risk levels after de-installation. The Canadian province of Ontario introduced a "Reduced Suspension with Ignition Interlock Conduct Review" Program, significantly changing pre-existing interlock policy. The Program incentivizes interlock installation and an "early" guilty plea. It also attempts to reduce long-term recidivism through behavioural feedback and compliance-based removal. This evaluation is the first in assessing Program impact. Ontario drivers with a first time alcohol-impaired driving conviction between July 1, 2005 and November 25, 2014 comprised the study cohort. Longitudinal analyses, using interrupted time series and Cox regression, were conducted in which exposure was the Program and the outcomes were ignition interlock installation (N=30,200), pre-trial elapsed time (N=30,200), and post-interlock recidivism (N=9326). After Program implementation, installation rates increased by 54% and pre-trial elapsed time decreased by 146 days. Results suggest no effect on post-interlock recidivism. Through an incentive-based design, this Program was effective at addressing two commonly cited barriers to interlock implementation- delayed eligibility for installation and low installation once eligible. Results reveal that installation rates are responsive not only to incentivization but also to other external factors, thus presenting an opportunity for policy makers to find unique ways to influence interlock uptake, and thereby, to extend their deterrent effects to a larger subset of the population. This study is one of the few that do not rely on proxy measures of installation rate. Copyright © 2016 Crown. Published by Elsevier Ltd.. All rights reserved.

  17. Teaching infant car seat installation via interactive visual presence: An experimental trial.

    PubMed

    Schwebel, David C; Johnston, Anna; Rouse, Jenni

    2017-02-17

    A large portion of child restraint systems (car seats) are installed incorrectly, especially when first-time parents install infant car seats. Expert instruction greatly improves the accuracy of car seat installation but is labor intensive and difficult to obtain for many parents. This study was designed to evaluate the efficacy of 3 ways of communicating instructions for proper car seat installation: phone conversation; HelpLightning, a mobile application (app) that offers virtual interactive presence permitting both verbal and interactive (telestration) visual communication; and the manufacturer's user manual. A sample of 39 young adults of child-bearing age who had no previous experience installing car seats were recruited and randomly assigned to install an infant car seat using guidance from one of those 3 communication sources. Both the phone and interactive app were more effective means to facilitate accurate car seat installation compared to the user manual. There was a trend for the app to offer superior communication compared to the phone, but that difference was not significant in most assessments. The phone and app groups also installed the car seat more efficiently and perceived the communication to be more effective and their installation to be more accurate than those in the user manual group. Interactive communication may help parents install car seats more accurately than using the manufacturer's manual alone. This was an initial study with a modestly sized sample; if results are replicated in future research, there may be reason to consider centralized "call centers" that provide verbal and/or interactive visual instruction from remote locations to parents installing car seats, paralleling the model of centralized Poison Control centers in the United States.

  18. Venting through multiple-layer insulation on Space Station Freedom. II - Ascent rate pressure chamber testing

    NASA Technical Reports Server (NTRS)

    Sharp, Jeffrey B.; Buitekant, Alan; Fay, John F.; Holladay, Jon B.

    1993-01-01

    A test was conducted to determine the venting characteristics of the multiple-layer insulation (MLI) to be installed on the Space Station Freedom (SSF). A full MLI blanket with inter-blanket joints was installed onto a model of a section of the SSF pressure wall, support structure, and debris shield. Data were taken from this test and were used to predict the venting of the actual Space Station pressure-wall/MLI/debris-shield assemply during launch and possible re-entry. It was found that the pressure differences across the debris shields and MLI blankets were well within the specified limits in all cases.

  19. Anesthesia information management systems: a review of functionality and installation considerations.

    PubMed

    Ehrenfeld, Jesse M; Rehman, Mohamed A

    2011-02-01

    The functionality and rate of implementation of Anesthesia Information Management Systems (AIMS) has markedly risen over the past decade. These systems have now become much more than the generic automated record keepers, originally proposed and developed in the 1980s. AIMS have now become complex integrated systems, which have been shown to improve patient care and, in some cases, the financial performance of a department. Although the underlying technology has improved greatly over the past 5 years, the process of selecting and completing an AIMS installation still presents a number of challenges, and must be approached carefully in order to maximize the benefits provided by these systems.

  20. A comparison of fuel savings in the residential and commercial sectors generated by the installation of solar heating and cooling systems under three tax credit scenarios

    NASA Astrophysics Data System (ADS)

    Moden, R.

    An analysis of expected energy savings between 1977 and 1980 under three different solar tax credit scenarios is presented. The results were obtained through the solar heating and cooling of buildings (SHACOB) commercialization model. This simulation provides projected savings of conventional fuels through the installation of solar heating and cooling systems on buildings in the residential and commercial sectors. The three scenarios analyzed considered the tax credits contained in the Windfall Profits Tax of April 1980, the National Tax Act of November 1978, and a case where no tax credit is in effect.

  1. Validating the use of scintillation proxies to study ionospheric scintillation over the Ugandan region

    NASA Astrophysics Data System (ADS)

    Amabayo, Emirant B.; Jurua, Edward; Cilliers, Pierre J.

    2015-06-01

    In this study, we compare the standard scintillation indices (S4 and σΦ) from a SCINDA receiver with scintillation proxies (S4p and | sDPR |) derived from two IGS GPS receivers. Amplitude (S4) and phase (σΦ) scintillation data were obtained from the SCINDA installed at Makerere University (0.34°N, 32.57°E). The corresponding amplitude (S4p) and phase (| sDPR |) scintillation proxies were derived from data archived by IGS GPS receivers installed at Entebbe (0.04°N, 32.44°E) and Mbarara (0.60°S, 30.74°E). The results show that for most of the cases analysed in this study, σΦ and | sDPR | are in agreement. Amplitude scintillation occurrence estimated using the S4p are fairly consistent with the standard S4, mainly between 17:00 UT and 21:00 UT, despite a few cases of over and under estimation of scintillation levels by S4p. Correlation coefficients between σΦ and the | sDPR | proxy revealed positive correlation. Generally, S4p and S4 exhibits both moderate and strong positive correlation. TEC depletions associated with equatorial plasma bubbles are proposed as the cause of the observed scintillation over the region. These equatorial plasma bubbles were evident along the ray paths to satellites with PRN 2, 15, 27 and 11 as observed from MBAR and EBBE. In addition to equatorial plasma bubbles, atmospheric gravity waves with periods similar to those of large scale traveling ionospheric disturbances were also observed as one of the mechanisms for scintillation occurrence. The outcome of this study implies that GPS derived scintillation proxies can be used to quantify scintillation levels in the absence of standard scintillation data in the equatorial regions.

  2. Parabolic Trough Collector Cost Update for the System Advisor Model (SAM)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurup, Parthiv; Turchi, Craig S.

    2015-11-01

    This report updates the baseline cost for parabolic trough solar fields in the United States within NREL's System Advisor Model (SAM). SAM, available at no cost at https://sam.nrel.gov/, is a performance and financial model designed to facilitate decision making for people involved in the renewable energy industry. SAM is the primary tool used by NREL and the U.S. Department of Energy (DOE) for estimating the performance and cost of concentrating solar power (CSP) technologies and projects. The study performed a bottom-up build and cost estimate for two state-of-the-art parabolic trough designs -- the SkyTrough and the Ultimate Trough. The SkyTroughmore » analysis estimated the potential installed cost for a solar field of 1500 SCAs as $170/m 2 +/- $6/m 2. The investigation found that SkyTrough installed costs were sensitive to factors such as raw aluminum alloy cost and production volume. For example, in the case of the SkyTrough, the installed cost would rise to nearly $210/m 2 if the aluminum alloy cost was $1.70/lb instead of $1.03/lb. Accordingly, one must be aware of fluctuations in the relevant commodities markets to track system cost over time. The estimated installed cost for the Ultimate Trough was only slightly higher at $178/m 2, which includes an assembly facility of $11.6 million amortized over the required production volume. Considering the size and overall cost of a 700 SCA Ultimate Trough solar field, two parallel production lines in a fully covered assembly facility, each with the specific torque box, module and mirror jigs, would be justified for a full CSP plant.« less

  3. AGOR 28

    DTIC Science & Technology

    2016-01-17

    sea trials 5 Spill pipe modification for chain locker installed. This should increase chain wrap around windlass. Divers cleaned hull...the ladder coming up from main to focstle deck and near the entrance to the deck locker stbd side forward. In the case of the deck locker moving

  4. 32 CFR Appendix A to Part 636 - References

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... INVESTIGATIONS MOTOR VEHICLE TRAFFIC SUPERVISION (SPECIFIC INSTALLATIONS) Pt. 636, App. A Appendix A to Part 636... 3946, Military Police Traffic Accident Report DA Form 3975, Military Police Report DD Form 1920... Understanding, Subject: Seizure of Assets for Administrative Forfeiture in Drug Related Cases. ...

  5. 32 CFR Appendix A to Part 636 - References

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... INVESTIGATIONS MOTOR VEHICLE TRAFFIC SUPERVISION (SPECIFIC INSTALLATIONS) Pt. 636, App. A Appendix A to Part 636... 3946, Military Police Traffic Accident Report DA Form 3975, Military Police Report DD Form 1920... Understanding, Subject: Seizure of Assets for Administrative Forfeiture in Drug Related Cases. ...

  6. Egypt`s first subsea completion: A Gulf of Suez case history

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    El Hawary, A.; Hoffman, J.G.

    1996-06-01

    A case history of the Gulf of Suez Petroleum Co.`s (Gupco) first subsea completion is provided. The first completion was for Well GS 373-2, a previously drilled and tested exploration well located in the south portion of the gulf of Suez. Subsea technology was used to economically justify development of this one-well marginal field, which was discovered in 1978. Traditional methods proved to be too costly for development, therefore application of a low-cost subsea tree was used to capture the resources. In the Gulf of Suez, many fields have been discovered but have not been developed because of low reserves.more » These marginal projects can have a profound impact on the revenue and shareholder value if an economic method is used to exploit these opportunities. Platform installation was not feasible because of reserve size, hence the well has remained abandoned until recently. This paper presents a summarized look at subsea completion technology. The cost comparison of traditional development methods will be made, given the local cost structure in Egypt. The application of this technology has some limitations and constraints that will be discussed in the paper. Furthermore, the actual field installation of Egypt`s first subsea tree will be summarized. Also included is a discussion on simple remote controls and offshore installation operations.« less

  7. A cost analysis of a smoke alarm installation and fire safety education program.

    PubMed

    Parmer, John E; Corso, Phaedra S; Ballesteros, Michael F

    2006-01-01

    While smoke alarm installation programs can help prevent residential fire injuries, the costs of running these programs are not well understood. We conducted a retrospective cost analysis of a smoke alarm installation program in 12 funded communities across four states. Costs included financial and economic resources needed for training, canvassing, installing, and following-up, within four cost categories: (a) personnel, (b) transportation, (c) facility, and (d) supplies. Local cost per completed home visit averaged 214.54 dollars, with an average local cost per alarm installed of 115.02 dollars. Combined state and local cost per alarm installed across all four states averaged 132.15 dollars. For every 1% increase in alarm installation, costs per alarm decrease by 1.32 dollars. As more smoke alarms are installed, the average installation cost per alarm decreases. By demonstrating effective economies of scale, this study suggests that smoke alarm programs can be implemented efficiently and receive positive economic returns on investment.

  8. Using Residential Solar PV Quote Data to Analyze the Relationship Between Installer Pricing and Firm Size

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Shaughnessy, Eric; Margolis, Robert

    2017-04-01

    The vast majority of U.S. residential solar PV installers are small local-scale companies, however the industry is relatively concentrated in a few large national-scale installers. We develop a novel approach using solar PV quote data to study the price behavior of large solar PV installers in the United States. Through a paired differences approach, we find that large installer quotes are about higher, on average, than non-large installer quotes made to the same customer. The difference is statistically significant and robust after controlling for factors such as system size, equipment quality, and time effects. The results suggest that low pricesmore » are not the primary value proposition of large installer systems. We explore several hypotheses for this finding, including that large installers are able to exercise some market power and/or earn returns from reputations.« less

  9. Case Study Analysis of U.S. Policy Solutions to Enable China New Energy Cities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simon, J.; Tian, T.; Liu, C.

    2015-05-28

    This report summarizes various policies for encouraging investment and installation of renewable energy across the country. In particular, we attempt to explain the benefits of, and considerations behind, each policy type and provide examples of implementation across the United States While recognized as important, this report does not address policies or examples of successful energy efficiency or alternative-fuel vehicle strategies. In addition, we summarize the renewable energy policy strategies undertaken by three areas of the United States: New Jersey, Hawaii, and San Francisco.

  10. Final Quality Assurance Project Plan, Installation Restoration Program Remedial Investigation/Feasibility Study, Kotzebue Long Range Radar Station, Alaska. Volume 2

    DTIC Science & Technology

    1994-10-01

    right side door. To minimize retinal exposure to UV, use UV protective eyeglasses and use the offset dental mirror to read the micrometer 6.7.4.3 To...States Air Force) Volatiles Analysis by GC/MS Method 8260 - (United States Air Force) Organochlorine Pesticides and PCBs by GC/ECD Method 8081...decreasing throughout the three or four exposures . The RSD will sometimes be higher than normal in these cases. Samples that are affected by possible carry

  11. Financial Optimization of Electricity Security Assets at Military Installations: Including Case Studies of Dover Air Force Base, Fort Benning, and MCAGCC Twentynine Palms

    DTIC Science & Technology

    2014-01-01

    kW) and Energy (kWh) Charges, Including Time-of-Use Energy Charges X X X X X Power Factor Improvement X X Emergency Demand Response... Capacity Market) X X X X X Other Capacity Sales X X X Frequency Regulation X X X X Spinning/Synchronous Reserve X X Blackstart Capacity X X X...Policy, Organizational, and Other Factors that can Accelerate Prudent Electricity Security Asset Investments and Uses 0% 2% 4% 6% 8% 10% 12% 14% 16

  12. Assessing Installation Ethnobotanical Resources Using Land Condition Trend Analysis (LCTA) Data: A Fort Riley, Kansas, Case Study

    DTIC Science & Technology

    1998-07-01

    Festuca arundinacea 3.3 4.0 S Fragaria virginiana 3.0 3.0 S Grindelia squarrosa 4.0 S Helianthus annuus 4.0 S Hieracium longipilum 4.0 G Hordeum...B Ceanothus serrulatus G L Asclepias verticillata S B Celastrus scandens S B Asclepias viridiflora S B Celtis occidentalis S B Asclepias viridis G...F Lythrum alatum S F Fragaria virginiana S B Lythrum califomicum S L Madura pomifera S B Polygonum aviculare S B Madia yosemitana G L Polygonum

  13. Guest Room Lighting at the Hilton Columbus Downtown

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2014-06-30

    At the Hilton Columbus Downtown hotel in Ohio, DOE's Better Buildings Alliance conducted a demonstration of Next Generation Luminaires-winning downlights installed in all guest rooms and suites prior to the hotel's 2012 opening. After a post-occupancy assessment, the LED downlights not only provided the aesthetic appearance and dimming functionality desired, but also provided 50% energy savings relative to a comparable CFL downlight and enabled the lighting power to be more than 20% below that allowed by code. This document is a summary case study of the report.

  14. Assessing health benefits of controlling air pollution from power generation: the case of a lignite-fired power plant in Thailand.

    PubMed

    Thanh, B D; Lefevre, T

    2001-02-01

    The impact pathway approach (IPA) is used to estimate quantitatively the level of health effects caused by particulate matter (PM10) and sulfur dioxide (SO2) emission from a lignite-fired power plant located in the Mae Moh area in northern region of Thailand. Health benefits are then assessed by comparing the levels of estimated health impacts without and with the installation of the flue gas desulfurization (FGD) equipment. The US EPA industrial source complex model is used to model air pollution dispersion at the local scale, and the sector average limited mixing meso-scale model is used to model air pollution transport at the regional scale. The quantification of the health end points in physical terms is carried out using the dose-response functions established recently for the population in Bangkok, Thailand. Monetarization of these effects is based on the benefit transfer method with appropriate adjustment. Finally, it has been found that the installation of the FGD to control SO2 emission at Mae Moh significantly reduces adverse health effects not only on the population living near the power plant but also all over the country. A FGD unit installed at the 300-MW power unit can result, on average, in 16 fewer cases of acute mortality, 12 fewer cases of respiratory and cardiac hospital admissions, and almost 354,000 fewer days with acute respiratory symptoms annually. In monetary terms this benefit is equivalent to US $18.2 million (1995 prices) per annum. This benefit is much higher than the annualized investment and operation costs of FGD (US $7.4 million/yr). Copyright 2001 Springer-Verlag

  15. Helicopter internal noise control: Three case histories

    NASA Technical Reports Server (NTRS)

    Edwards, B. D.; Cox, C. R.

    1978-01-01

    Case histories are described in which measurable improvements in the cabin noise environments of the Bell 214B, 206B, and 222 were realized. These case histories trace the noise control efforts followed in each vehicle. Among the design approaches considered, the addition of a fluid pulsation damper in a hydraulic system and the installation of elastomeric engine mounts are highlighted. It is concluded that substantial weight savings result when the major interior noise sources are controlled by design, both in altering the noise producing mechanism and interrupting the sound transmission paths.

  16. Residential solar energy users: a review of empirical research and related literature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Unseld, C.T.; Crews, R.

    1979-12-01

    This report reviews 15 empirical studies of residential solar energy users and related literature on residential solar energy use. The purpose of the review is to summarize and analyze the experiences of residential solar users for helping formulate policies concerning the accelerated commercialization of solar technologies. Four of the studies employed case histories or focus group techniques. The 11 questionnaire studies represented interviews with over 1,600 owners of solar systems. The demographic characteristics of samples are listed and compared; research findings and conclusions are presented. Findings on user satisfaction and system performance, possible reasons for evidence of lacking correlation betweenmore » them, and implications for consumer protection and future research are discussed. General findings are: (1) systematic research on the experiences of solar users is lacking - much research remains to be done; (2) the reported overall experiences of users has been very positive; (3) user reports indicate that system performance is generally good but there is some evidence that user reports are not accurate measures of actual performance; (4) a need exists for adequate consumer protection; (5) design or installation problems are evidenced in significant numbers of early solar installations; and (6) these problems evidently are resolvable. An annotated bibliography describes 10 other studies in progress.« less

  17. Geographical variation in mortality from leukaemia and other cancers in England and Wales in relation to proximity to nuclear installations, 1969-78.

    PubMed Central

    Cook-Mozaffari, P. J.; Darby, S. C.; Doll, R.; Forman, D.; Hermon, C.; Pike, M. C.; Vincent, T.

    1989-01-01

    The distribution of mortality from 11 causes of death (lymphoid leukaemia, other leukaemia, leukaemia of all types, Hodgkin's disease, other lymphomas, all lymphomas, multiple myeloma, lung cancer, other malignancies, all malignancies and all other causes) has been examined in three age groups throughout England and Wales over the period 1969-78. The reorganisation of local authority administration in 1974 meant that the smallest areas that could be examined were 400 county districts or (in some cases) approximate county districts formed by aggregating pre-1974 local authority areas. The variation in the numbers of deaths observed about the numbers expected was assessed using log-linear models to estimate the effect on the relative risk in each district associated with social class, rural status, population size, health authority region and proximity to one of 15 nuclear installations. Trends in risk with increasing proximity to an installation (as judged by the proportion of the population resident within 10 miles) were examined after adjustment for the other four variables. The results showed that in districts near to an installation there were significant excess mortalities in persons under 25 years of age from leukaemia (RR = 1.15, P = 0.01) and especially from lymphoid leukaemia (RR 1.21, P = 0.01) and from Hodgkin's disease (RR 1.24, P = 0.05) and a significant deficiency of mortality from lymphoid leukaemia in persons aged 25-64 years. No significant trends were observed with an increasing proportion of the population near to the installations and the greatest excess mortality from lymphoid leukaemia in young persons was observed in the districts with the intermediate proportion of the population (10.0-65.9%) near an installation. PMID:2930718

  18. Early warning system for potential churners among mortgage customers

    NASA Astrophysics Data System (ADS)

    Irpan, Hamidah Muhd; Aidid, Sharifah Sakinah Syed Hassan; Mohmad, Sarahiza; Ibrahim, Noorazilah

    2014-07-01

    Retaining existing customer is a major task for many companies because cost to acquire new customers is higher than retaining existing customers. For mortgage business in Bank X, customer relationship management plays a big role to understand their customers' profile and churners so that suitable action can be done to retain their potential churners. Objectives of this study are (1) understanding their customers' profile and churners, (2) modeling potential churners using neural network model and (3) to deploy the model to identify potential churners. Data was divided into two parts: sampling (67,470 cases) and scoring (4,488 cases). Analysis was done using SAS Enterprise Miner. Dependent variable is churner/non churner while independent variables are balance and amount of loan, interest rate offered installment amount, loan performance, months in arrear, vintage, tenure, age, race and gender. Potential churners were identified as Malays, followed by Indian, other races and Chinese. Nonperforming loan and male customers tend to churn compared to performing loan and female customers. Younger customers with small loan amount, balance and monthly instalment, higher interest rate, have many months in arrears, longer vintage and tenure have higher tendency to churn from Bank X. Hence, Bank X should focus on the potential churners for their campaign to minimize the expenses of retaining existing customers by doing an effective campaign with high successful rate.

  19. Impacts of potential CO2-reduction policies on air quality in the United States.

    PubMed

    Trail, Marcus A; Tsimpidi, Alexandra P; Liu, Peng; Tsigaridis, Kostas; Hu, Yongtao; Rudokas, Jason R; Miller, Paul J; Nenes, Athanasios; Russell, Armistead G

    2015-04-21

    Impacts of emissions changes from four potential U.S. CO2 emission reduction policies on 2050 air quality are analyzed using the community multiscale air quality model (CMAQ). Future meteorology was downscaled from the Goddard Institute for Space Studies (GISS) ModelE General Circulation Model (GCM) to the regional scale using the Weather Research Forecasting (WRF) model. We use emissions growth factors from the EPAUS9r MARKAL model to project emissions inventories for two climate tax scenarios, a combined transportation and energy scenario, a biomass energy scenario and a reference case. Implementation of a relatively aggressive carbon tax leads to improved PM2.5 air quality compared to the reference case as incentives increase for facilities to install flue-gas desulfurization (FGD) and carbon capture and sequestration (CCS) technologies. However, less capital is available to install NOX reduction technologies, resulting in an O3 increase. A policy aimed at reducing CO2 from the transportation sector and electricity production sectors leads to reduced emissions of mobile source NOX, thus reducing O3. Over most of the U.S., this scenario leads to reduced PM2.5 concentrations. However, increased primary PM2.5 emissions associated with fuel switching in the residential and industrial sectors leads to increased organic matter (OM) and PM2.5 in some cities.

  20. Costs to Automate Demand Response - Taxonomy and Results from Field Studies and Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piette, Mary A.; Schetrit, Oren; Kiliccote, Sila

    During the past decade, the technology to automate demand response (DR) in buildings and industrial facilities has advanced significantly. Automation allows rapid, repeatable, reliable operation. This study focuses on costs for DR automation in commercial buildings with some discussion on residential buildings and industrial facilities. DR automation technology relies on numerous components, including communication systems, hardware and software gateways, standards-based messaging protocols, controls and integration platforms, and measurement and telemetry systems. This report compares cost data from several DR automation programs and pilot projects, evaluates trends in the cost per unit of DR and kilowatts (kW) available from automated systems,more » and applies a standard naming convention and classification or taxonomy for system elements. Median costs for the 56 installed automated DR systems studied here are about $200/kW. The deviation around this median is large with costs in some cases being an order of magnitude great or less than the median. This wide range is a result of variations in system age, size of load reduction, sophistication, and type of equipment included in cost analysis. The costs to automate fast DR systems for ancillary services are not fully analyzed in this report because additional research is needed to determine the total cost to install, operate, and maintain these systems. However, recent research suggests that they could be developed at costs similar to those of existing hot-summer DR automation systems. This report considers installation and configuration costs and does include the costs of owning and operating DR automation systems. Future analysis of the latter costs should include the costs to the building or facility manager costs as well as utility or third party program manager cost.« less

  1. Long Valley Deep Hole Geophysical Observatory --- Strain Instrumentation and Installation.

    NASA Astrophysics Data System (ADS)

    Sacks, S. I.; Linde, A.; Malin, P.; Roeloffs, E. A.; Hill, D. P.; Ellsworth, W. L.

    2003-12-01

    The Long Valley Exploratory Well, drilled in the middle of the resurgent dome in the Long Valley caldera, was started in 1989 and after rather checkered progress eventually reached a depth of about 9,831 feet. The hole is cased to a depth of 7178 feet with bare rock below that. At 8,500 feet there is an open fracture system with substantial permeability. One of the goals of the instrument installation is to enable monitoring of this deep aquifer. The most satisfactory rock away from obvious large fractures was at about 7,400 feet, and this was the installation depth. The instrumentation package consisted of a bottom hole seismometer at a depth of about 8500 feet, and a coupled instrument string that was cemented to the rock at a depth of 7400 feet. The instrument string, 73 feet long, had an inflatable packer with an extension at the bottom, coupled to a seismometer with a cement exit port above it, a 22 foot long spacing tube connected to a 20 foot long sensing volume strainmeter assembly. The strainmeter unit is essentially an annulus with the cementing pipe passing through it. In addition, two seismometer cables, two water bypass tubes and a packer inflation tube, pass through the strainmeter, which is actually two concentric strainmeters. The outer unit is a dilatometer and the inner unit is a vertical component strainmeter. Before installation, the strainmeters and the 8000 foot long stainless steel coupling tubes were filled with filtered and degassed water. The instrument string and attached bottom hole seismometer were then lowered down the hole attached to drill pipe. Two optical fiber vertical strainmeters (one interferometer and one time-of-flight loop) consisting of three fibers were attached to the drill pipe as it was installed. After the drill pipe reached target depth, it was secured to the well head. The packer, at the bottom of the instrument package, was inflated, thus providing a sealed bottom for the cement. Cement was then pumped down the drill pipe, through the strainmeter assembly and out the tube about 25 feet below the bottom of the strain sensing assembly. About 450 feet of the hole was cemented, the cement going into the casing. The coupling tubes from the strainmeters were connected to a surface mounted sensing head that had hydraulic amplification and electronic transducers. Pressure changes in the lower aquifer cause flow through two 1/4 inch diameter tubes into the annulus outside the mounting and cementing pipe. An opening sleeve in the installed pipe will allow the resulting water level changes to be monitored in a protected environment. All installed instrumentation seems to be functioning satisfactorily.

  2. Marginal and apical bone stability after staged sinus floor augmentation using bone condensing implants with variable-thread design: a two-dimensional analysis.

    PubMed

    Younes, F; Eghbali, A; De Troyer, S; De Bruyckere, T; Cleymaet, R; Cosyn, J

    2016-09-01

    Studies on the vertical stability of augmented bone after sinus lifting differ substantially. In addition, long healing periods are usually advocated prior to implant installation. The purpose of this case series study was to evaluate the changes in bone height after sinus lifting with a bovine-derived xenograft and to evaluate the clinical outcome of bone condensing implants installed after a short healing period. Patients treated during the years 2010-2013 were re-examined using peri-apical radiographs to evaluate the changes in augmented bone height (BH) and marginal bone loss (BL). Fifty-seven of 70 eligible subjects (28 male and 29 female, mean age 56 years) attended for reassessment. Data were available for 53 sinus lifts and 105 implants installed after a mean healing period of 4.6±1.5 months. Implant survival was 99% after a mean time in function of 19±9 months. Baseline BH, BH at implant placement, and final BH were on average 3.87±1.74mm, 13.75±2.12mm, and 13.11±2.12mm, respectively (P<0.001). Mean BL was 0.51±0.65mm. Only limited resorption is to be expected after sinus lifting in the short term. A bone condensing implant can be used in the early healing phase with successful outcomes in terms of implant survival and bone adaptation. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. Permeability profiles in granular aquifers using flowmeters in direct-push wells

    USGS Publications Warehouse

    Paradis, D.; Lefebvre, R.; Morin, R.H.; Gloaguen, E.

    2010-01-01

    Numerical hydrogeological models should ideally be based on the spatial distribution of hydraulic conductivity (K), a property rarely defined on the basis of sufficient data due to the lack of efficient characterization methods. Electromagnetic borehole flowmeter measurements during pumping in uncased wells can effectively provide a continuous vertical distribution of K in consolidated rocks. However, relatively few studies have used the flowmeter in screened wells penetrating unconsolidated aquifers, and tests conducted in gravel-packed wells have shown that flowmeter data may yield misleading results. This paper describes the practical application of flowmeter profiles in direct-push wells to measure K and delineate hydrofacies in heterogeneous unconsolidated aquifers having low-to-moderate K (10−6 to 10−4 m/s). The effect of direct-push well installation on K measurements in unconsolidated deposits is first assessed based on the previous work indicating that such installations minimize disturbance to the aquifer fabric. The installation and development of long-screen wells are then used in a case study validating Kprofiles from flowmeter tests at high-resolution intervals (15 cm) with K profiles derived from multilevel slug tests between packers at identical intervals. For 119 intervals tested in five different wells, the difference in log K values obtained from the two methods is consistently below 10%. Finally, a graphical approach to the interpretation of flowmeter profiles is proposed to delineate intervals corresponding to distinct hydrofacies, thus providing a method whereby both the scale and magnitude of K contrasts in heterogeneous unconsolidated aquifers may be represented.

  4. Permeability profiles in granular aquifers using flowmeters in direct-push wells.

    PubMed

    Paradis, Daniel; Lefebvre, René; Morin, Roger H; Gloaguen, Erwan

    2011-01-01

    Numerical hydrogeological models should ideally be based on the spatial distribution of hydraulic conductivity (K), a property rarely defined on the basis of sufficient data due to the lack of efficient characterization methods. Electromagnetic borehole flowmeter measurements during pumping in uncased wells can effectively provide a continuous vertical distribution of K in consolidated rocks. However, relatively few studies have used the flowmeter in screened wells penetrating unconsolidated aquifers, and tests conducted in gravel-packed wells have shown that flowmeter data may yield misleading results. This paper describes the practical application of flowmeter profiles in direct-push wells to measure K and delineate hydrofacies in heterogeneous unconsolidated aquifers having low-to-moderate K (10(-6) to 10(-4) m/s). The effect of direct-push well installation on K measurements in unconsolidated deposits is first assessed based on the previous work indicating that such installations minimize disturbance to the aquifer fabric. The installation and development of long-screen wells are then used in a case study validating K profiles from flowmeter tests at high-resolution intervals (15 cm) with K profiles derived from multilevel slug tests between packers at identical intervals. For 119 intervals tested in five different wells, the difference in log K values obtained from the two methods is consistently below 10%. Finally, a graphical approach to the interpretation of flowmeter profiles is proposed to delineate intervals corresponding to distinct hydrofacies, thus providing a method whereby both the scale and magnitude of K contrasts in heterogeneous unconsolidated aquifers may be represented. Journal compilation © 2010 National Ground Water Association. No claim to original US government works.

  5. Finite elements analysis of an underground collector installed by pipe-jacking method

    NASA Astrophysics Data System (ADS)

    María Díaz-Díaz, Luis; Omer, Joshua; Arias, Daniel; Pando, Luis

    2016-04-01

    This study presents a useful analysis method for estimating simultaneously the stability, stress distribution and groundwater seepage as micro - tunnel is being advanced into the ground. The research is mainly concerned with the results of a case study conducted on a project to create a long industrial collector of effluent network in the east bank of the river Avilés (north coast of Spain). This coastal city has significant port and industrial installations in its environs. The geology of the location comprises Quaternary deposits on both flanks of the estuary and includes different highly variable geotechnical behavior. The industrial effluent network, constructed in the year 2010, has a length of 13.087 km and consists of 1.5 m diameter pipes, reaching a maximum depth of 5.8 m below the surface. Only the first 7.0 km of the collector (south area) were formed using pipe-jacking method whilst the rest were formed in open excavations or surface laid. Using the commercial software RS2, a 2D finite element program for soil and rock application, the ground response to pipe jacking in pipeline installation in Avilés was analyzed. Both axi-symmetric and plane strain analyses were carried out in RS2 to simulate in 3D the ground response to pipe advancement. The results demonstrate how much of deformation there is at ground surface in the immediate vicinity of the pipeline. The main objective is to show the possible patterns of ground subsidence and tunnel stresses to inform designers as to whether the tunnel will be stable and safe.

  6. Future landfill emissions and the effect of final cover installation--a case study.

    PubMed

    Laner, David; Fellner, Johann; Brunner, Paul H

    2011-07-01

    Municipal solid waste (MSW) landfills are potential long-term sources of emissions. Hence, they need to be managed after closure until they do not pose a threat to humans or the environment. The case study on the Breitenau MSW landfill was performed to evaluate future emission levels for this site and to illustrate the effect of final cover installation with respect to long-term environmental risks. The methodology was based on a comprehensive assessment of the state of the landfill and included analysis of monitoring data, investigations of landfilled waste, and an evaluation of containment systems. A model to estimate future emission levels was established and site-specific predictions of leachate emissions were presented based on scenario analysis. The results are used to evaluate the future pollution potential of the landfill and to compare different aftercare concepts in view of long-term emissions. As some leachable substances became available for water flow during cover construction due to a change in the water flow pattern of the waste, a substantial increase in leachate concentrations could be observed at the site (e.g. concentrations of chloride increased from 200 to 800 mg/l and of ammonia-nitrogen from 140 to about 500 mg/l). A period of intensive flushing before the final cover installation could have reduced the amount of leachable substances within the landfill body and rapidly decreased the leachate concentrations to 11 mg Cl/l and 79 mg NH(4)-N/l within 50 years. Contrarily, the minimization of water infiltration is associated with leachate concentrations in a high range for centuries (above 400 mg Cl/l and 200 mg NH(4)-N/l) with low concomitant annual emission loads (below 12 kg/year of Cl or 9 kg/year of NH(4)-N, respectively). However, an expected gradual decrease of barrier efficiency over time would be associated with higher emission loads of 50 kg of chloride and 30 kg of ammonia-nitrogen at the maximum, but a faster decrease of leachate concentration levels. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. [Effects of performance-volume limit on the institutional financing of the Clinical Centre of the University of Pécs, Hungary].

    PubMed

    Endrei, Dóra; Kollár, Lajos; Bódis, József; Imhof, Gábor; Zemplényi, Antal; Vas, Gábor; Boncz, Imre

    2010-08-01

    The aim of our study is to demonstrate the effects of performance-volume limit (PVL) on the institutional financing of the Clinical Centre of the University of Pécs (CC UP). The data involved in the analysis are based on the reports towards the National Health Insurance Fund Administration (NHIFA), concerning the active inpatient care by specialist in the period between 2004 and 2008. We determined the real NHIFA reimbursement per weighted case number and the financial loss caused by the PVL. We analyzed the proportion of local health care obligation and urgency cases in comparison of various clinics. The reimbursement per weighted case number of CC UP has been less than the pre-announced NHIFA amounts after the installation of PVL. During the examined 5 years, i.e. 2004-2008, the loss in case of CC UP has been up to 3.256 million HUF due to the PVL. Concerning the whole of CC UP it means that 25.3 % of the treated cases and 24.5 % of the executed weighted case number has been out of local health care obligation. Studying the ratio of urgency cases inside the total volume of medical attendance, it is represented that 31.5 % of the cases and 36.1 % of the weighted case numbers came from the treatment of urgency cases. The introduction of performance-volume limit considerably reduced the health insurance financing of CC UP between 2004 and 2008.

  8. Feasibility and acceptability of insecticide-treated plastic sheeting (ITPS) for vector control in Papua New Guinea

    PubMed Central

    2012-01-01

    Background This study assessed the feasibility and acceptability of utilizing insecticide-treated plastic sheeting (ITPS) as a malaria control intervention in Papua New Guinea (PNG). Methods ZeroVector® ITPS was installed in 40 homes across four study sites representing a cross section of malaria transmission risk and housing style. Structured questionnaires were completed at the time of ITPS installation (n=40) and at four weeks post installation (n=40) with the household head. Similarly, group interviews with the male and/or female household heads were completed at installation (n=5) and four-week follow-up (n=4). Results ZeroVector® ITPS was successfully installed in a range of homes employing traditional and/or modern building materials in PNG. The ITPS installations remained intact over the course of the four-week trial period and were highly acceptable to both male and female household heads. No dissatisfaction with the ITPS product was reported at four-week follow-up; however, the installation process was time consuming, participants reported a reduction in mosquito net use following ITPS installation and many participants expressed concern about the longevity of ITPS over the longer term. Conclusion ZeroVector® ITPS installation is feasible and highly acceptable in a diverse range of PNG contexts and is likely to be favourably received as a vector control intervention if accessible en masse. A longer-term evaluation is required before firm policy or public health decisions can be made regarding the potential application of ITPS in the national malaria control programme. The positive study findings suggest a longer-term evaluation of this promising malaria control intervention warrants consideration. PMID:23046535

  9. Feasibility and acceptability of insecticide-treated plastic sheeting (ITPS) for vector control in Papua New Guinea.

    PubMed

    Pulford, Justin; Tandrapah, Anthony; Atkinson, Jo-An; Kaupa, Brown; Russell, Tanya; Hetzel, Manuel W

    2012-10-09

    This study assessed the feasibility and acceptability of utilizing insecticide-treated plastic sheeting (ITPS) as a malaria control intervention in Papua New Guinea (PNG). ZeroVector® ITPS was installed in 40 homes across four study sites representing a cross section of malaria transmission risk and housing style. Structured questionnaires were completed at the time of ITPS installation (n=40) and at four weeks post installation (n=40) with the household head. Similarly, group interviews with the male and/or female household heads were completed at installation (n=5) and four-week follow-up (n=4). ZeroVector® ITPS was successfully installed in a range of homes employing traditional and/or modern building materials in PNG. The ITPS installations remained intact over the course of the four-week trial period and were highly acceptable to both male and female household heads. No dissatisfaction with the ITPS product was reported at four-week follow-up; however, the installation process was time consuming, participants reported a reduction in mosquito net use following ITPS installation and many participants expressed concern about the longevity of ITPS over the longer term. ZeroVector® ITPS installation is feasible and highly acceptable in a diverse range of PNG contexts and is likely to be favourably received as a vector control intervention if accessible en masse. A longer-term evaluation is required before firm policy or public health decisions can be made regarding the potential application of ITPS in the national malaria control programme. The positive study findings suggest a longer-term evaluation of this promising malaria control intervention warrants consideration.

  10. Solar For Schools: A Case Study in Identifying and Implementing Solar Photovoltaic (PV) Projects in Three California School Districts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kandt, A.

    2011-01-01

    The Department of Energy's (DOE) Solar America Showcase program seeks to accelerate demand for solar technologies among key end use market sectors. As part of this activity, DOE provides technical assistance through its national laboratories to large-scale, high-visibility solar installation projects. The Solar Schools Assessment and Implementation Project (SSAIP) in the San Francisco Bay Area was selected for a 2009 DOE Solar America Showcase award. SSAIP was formed through the efforts of the nonprofit Sequoia Foundation and includes three school districts: Berkeley, West Contra Costa, and Oakland Unified School Districts. This paper summarizes the technical assistance efforts that resulted frommore » this technical assistance support. It serves as a case study and reference document detailing the steps and processes that could be used to successfully identify, fund, and implement solar photovoltaics (PV) projects in school districts across the country.« less

  11. Meals on Wheels? A Decade of Megafaunal Visual and Acoustic Observations from Offshore Oil & Gas Rigs and Platforms in the North and Irish Seas

    PubMed Central

    Todd, Victoria Louise Georgia; Todd, Ian Boyer

    2016-01-01

    A decade of visual and acoustic detections of marine megafauna around offshore Oil & Gas (O&G) installations in the North and Irish Seas are presented. Marine megafauna activity was monitored visually and acoustically by Joint Nature Conservation Committee (JNCC) qualified and experienced Marine Mammal Observers (MMO) and Passive Acoustic Monitoring (PAM) Operators respectively, with real-time towed PAM in combination with industry standard software, PAMGuard. Monitoring was performed during routine O&G industrial operations for underwater noise mitigation purposes, and to ensure adherence to regulatory guidelines. Incidental sightings by off-effort MMOs and installation crew were also reported. Visual and acoustic monitoring spanned 55 non-consecutive days between 2004 and 2014. A total of 47 marine mammal sightings were recorded by MMOs on dedicated watch, and 10 incidental sightings of marine megafauna were reported over 10 years. Species included: harbour porpoise (Phocoena phocoena), Atlantic white-sided dolphin (Lagenorhynchus acutus), white beaked dolphin (Lagenorhynchus albirostris), common dolphin (Delphinus delphis), minke whale (Balaenoptera acutorostrata), common seal (Phoca vitulina), grey seal (Halichoerus grypus) and, basking shark (Cetorhinus maximus). Passive Acoustic Monitoring was conducted on two occasions in 2014; 160 PAM hours over 12 days recorded a total of 308 individual clicks identified as harbour porpoises. These appear to be the first such acoustic detections obtained from a North Sea drilling rig whilst using a typically configured hydrophone array designed for towing in combination with real-time PAMGuard software. This study provides evidence that marine megafauna are present around mobile and stationary offshore O&G installations during routine operational activities. On this basis, Environmental Impact Assessments (EIAs) for decommissioning O&G platforms should be carried-out on a case-by-case basis, and must include provisions for hitherto overlooked marine megafauna. PMID:27078153

  12. Designing effective incentives for energy conservation in the public sector

    NASA Astrophysics Data System (ADS)

    Drezner, Jeffrey Alan

    Understanding why government officials behave in certain ways under particular circumstances is an important theme in political science. This research explores the design of policies and incentives targeted at public sector officials, in particular the use of market based policy tools in a non-market environment, and the influence of that organizational environment on the effectiveness of the policy. The research examines the case of Department of Defense (DoD) facility energy management. DoD energy policy includes a provision for the retention of savings generated by conservation activities: two-thirds of the savings is retained at the installation generating the savings, half to used for further investment in energy conservation, and half to be used for general morale, welfare, and recreation activities. This policy creates a financial incentive for installation energy managers to establish higher quality and more active conservation programs. A formal written survey of installation energy managers within DoD was conducted, providing data to test hypotheses regarding policy effectiveness and factors affecting policy implementation. Additionally, two detailed implementation case studies were conducted in order to gain further insights. Results suggest that policy design needs to account for the environment within which the policy will be implemented, particularly organizational culture and standard operating procedures. The retention of savings policy failed to achieve its intended outcome---retention of savings for re-investment in energy conservation---because the role required of the financial management community was outside its normal mode of operation and interests and the budget process for allocating resources did not include a mechanism for retention of savings. The policy design did not adequately address these start-up barriers to implementation. This analysis has shown that in order for retention of savings, or similar policies based on market-type mechanisms, to be effective in the public sector context, the required cultural changes and appropriate implementing mechanisms must be provided for in the policy design.

  13. Interactions of Marine Hydrokinetic Devices in Complex Bathymetries: Numerical Simulations in the Chacao Channel in Southern Chile.

    NASA Astrophysics Data System (ADS)

    Soto, K. A.; Escauriaza, C. R.; Richter, D. H.

    2015-12-01

    Many coastal areas in the South Pacific Ocean can provide significant marine energy resources in the near future. The installation of marine hydrokinetic (MHK) devices in these regions will require new approaches to understand physical and environmental processes that are relevant for the installation of turbine arrays, which are also specific of each site. The coastal morphology of the Chacao channel in southern Chile, which separates the Chiloé island from the main continent (41º47'S, 73º31'W) stands out as an important energy resource that can potentially contribute a significant power capacity. This coastal area not only sustains delicate ecosystems with limited anthropic intervention, but it is characterized by a complex bathymetry that can have important effects on the performance of MHK devices and their local impacts. To understand the interactions of the local bathymetry and ambient turbulence with turbine arrays, we carry out a series of numerical simulations with a coherent-structure resolving turbulence model using the actuator disk parameterization. The main objective of this study is to further our understanding on the physical processes associated with the installation of the turbine arrays. We perform simulations with different geometries and inlet boundary conditions, from simple cases in a rectangular channel, to more complex cases that include the high-resolution bathymetry of an extensive area of the Chacao channel. The results show how the interactions between the MHK devices, the local flow, and the bed can affect the energy flux and potential generation in specific sites. The results also provide new insights of local impacts of MHK devices and they can also help to optimize turbine arrays in natural environments. This work has been supported by Fondecyt project 1130940, and the Marine Energy Research & Innovation Center (MERIC) financed by Corfo and based in Santiago, Chile.

  14. Ground-source heat pump case studies and utility programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lienau, P.J.; Boyd, T.L.; Rogers, R.L.

    1995-04-01

    Ground-source heat pump systems are one of the promising new energy technologies that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to consumers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school and commercial building applications. In order to verify the performance, information was collected for 253 case studies from mainly utilities throughout the United States. The casemore » studies were compiled into a database. The database was organized into general information, system information, ground system information, system performance, and additional information. Information was developed on the status of demand-side management of ground-source heat pump programs for about 60 electric utility and rural electric cooperatives on marketing, incentive programs, barriers to market penetration, number units installed in service area, and benefits.« less

  15. An evaluation of retrofit engineering control interventions to reduce perchloroethylene exposures in commercial dry-cleaning shops.

    PubMed

    Earnest, G Scott; Ewers, Lynda M; Ruder, Avima M; Petersen, Martin R; Kovein, Ronald J

    2002-02-01

    Real-time monitoring was used to evaluate the ability of engineering control devices retrofitted on two existing dry-cleaning machines to reduce worker exposures to perchloroethylene. In one dry-cleaning shop, a refrigerated condenser was installed on a machine that had a water-cooled condenser to reduce the air temperature, improve vapor recovery, and lower exposures. In a second shop, a carbon adsorber was retrofitted on a machine to adsorb residual perchloroethylene not collected by the existing refrigerated condenser to improve vapor recovery and reduce exposures. Both controls were successful at reducing the perchloroethylene exposures of the dry-cleaning machine operator. Real-time monitoring was performed to evaluate how the engineering controls affected exposures during loading and unloading the dry-cleaning machine, a task generally considered to account for the highest exposures. The real-time monitoring showed that dramatic reductions occurred in exposures during loading and unloading of the dry-cleaning machine due to the engineering controls. Peak operator exposures during loading and unloading were reduced by 60 percent in the shop that had a refrigerated condenser installed on the dry-cleaning machine and 92 percent in the shop that had a carbon adsorber installed. Although loading and unloading exposures were dramatically reduced, drops in full-shift time-weighted average (TWA) exposures were less dramatic. TWA exposures to perchloroethylene, as measured by conventional air sampling, showed smaller reductions in operator exposures of 28 percent or less. Differences between exposure results from real-time and conventional air sampling very likely resulted from other uncontrolled sources of exposure, differences in shop general ventilation before and after the control was installed, relatively small sample sizes, and experimental variability inherent in field research. Although there were some difficulties and complications with installation and maintenance of the engineering controls, this study showed that retrofitting engineering controls may be a feasible option for some dry-cleaning shop owners to reduce worker exposures to perchloroethylene. By installing retrofit controls, a dry-cleaning facility can reduce exposures, in some cases dramatically, and bring operators into compliance with the Occupational Safety and Health Administration (OSHA) peak exposure limit of 300 ppm. Retrofit engineering controls are also likely to enable many dry-cleaning workers to lower their overall personal TWA exposures to perchloroethylene.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, W.M.; Tison, M.; Bahoumina, A.

    The tieback of eleven 10 3/4-in., high-pressure risers in Elf Congo`s offshore N`Kossa field used a cold-forge tieback system to create a metal seal. The time-saving tieback method allows for placing the risers in residual tension. The installation work was completed in the fall of 1995. Average time to complete the 10 3/4-in. casing tiebacks, including test and nipple-up and nipple-down times, averaged 52 hr/well. Tiebacks for all three casing strings averaged 90 hr for all surface and subsea operations including BOP test and nipple-up/nipple-down time. Metal sealing of the primary casing annulus has been made practical because the offshoremore » industry has gone toward compact-wellheads and hanging of the completion on a mandrel. Hanging the completion on a mandrel, however, has it own set of considerations. Exact riser length may be difficult to predict before running because the riser must first be locked into the mudline casing hanger and then landed out on the support shoulder in the surface head. Also, a general desire is that riser tieback strings should be in tension after installation. This is not always easy with a passive or dumb hanger and fixed should configuration. Threaded, adjustable mandrel hanger systems exist but can require very close casing string space-out to achieve the desired residual riser tension. The paper describes the objectives, forged sleeves, running sequence, cold forging, and the prototype test.« less

  17. Case Study of Airborne Pathogen Dispersion Patterns in Emergency Departments with Different Ventilation and Partition Conditions

    PubMed Central

    Cheong, Chang Heon; Lee, Seonhye

    2018-01-01

    The prevention of airborne infections in emergency departments is a very important issue. This study investigated the effects of architectural features on airborne pathogen dispersion in emergency departments by using a CFD (computational fluid dynamics) simulation tool. The study included three architectural features as the major variables: increased ventilation rate, inlet and outlet diffuser positions, and partitions between beds. The most effective method for preventing pathogen dispersion and reducing the pathogen concentration was found to be increasing the ventilation rate. Installing partitions between the beds and changing the ventilation system’s inlet and outlet diffuser positions contributed only minimally to reducing the concentration of airborne pathogens. PMID:29534043

  18. Case Study of Airborne Pathogen Dispersion Patterns in Emergency Departments with Different Ventilation and Partition Conditions.

    PubMed

    Cheong, Chang Heon; Lee, Seonhye

    2018-03-13

    The prevention of airborne infections in emergency departments is a very important issue. This study investigated the effects of architectural features on airborne pathogen dispersion in emergency departments by using a CFD (computational fluid dynamics) simulation tool. The study included three architectural features as the major variables: increased ventilation rate, inlet and outlet diffuser positions, and partitions between beds. The most effective method for preventing pathogen dispersion and reducing the pathogen concentration was found to be increasing the ventilation rate. Installing partitions between the beds and changing the ventilation system's inlet and outlet diffuser positions contributed only minimally to reducing the concentration of airborne pathogens.

  19. France: Thrust and parry over nuclear risks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balter, M.

    1997-01-31

    Claims about the health risks posed by nuclear-power installations are always controversial, but nowhere more so than in France, where some 75% of the nation`s electricity is generated from nuclear energy. So, it was no surprise that publication of a study by two French epidemiologists earlier this month claiming to show a link between cases of childhood leukemia and the nuclear-waste reprocessing plant at La Hague on the Normandy coast sparked fireworks in the French press. Several French epidemiologists sharply criticized the study`s methodology and conclusions. Their attacks have now drawn an unusual response from the British Medical Journal (BMJ),more » in which the paper appeared.« less

  20. Technoeconomic evaluation of urban plant factories: The case of basil (Ocimum basilicum).

    PubMed

    Liaros, Stelios; Botsis, Konstantinos; Xydis, George

    2016-06-01

    Greece is currently in a turmoil, experiencing the effects of more than half a decade of economic crisis. Public health and welfare, jobs and wages, labor market concerning employment as long as employability of the work force, inequality, life satisfaction and housing, tourism and environment, economic and energy poverty are heavily impacted by Greece's disadvantageous economic situation. Real estate market could not have gotten away from the financial commotion, being currently in a halt after years of rapid decline. Fired from the present situation of Greece's real estate market, the present study is concerned with the investigation of alternative ways to support the local real estate market. With respect to sustainable development's ethics, the development, implementation, installation and operation of small, inexpensive plant factories within the urban environment is evaluated. Installations such are those, will encourage the penetration of a new market for the untapped buildings' resource, advancing new investing opportunities, promoting economic growth and productivity while creating a new labor market. The study will rely on the basic principles of Life Cycle Costing Assessment and develop a methodology upon which different scenarios will be evaluated against the "Do Nothing" scenario. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. The Cost-Effectiveness of Lowering Permissible Noise Levels Around U.S. Airports

    PubMed Central

    Jiao, Boshen; Zafari, Zafar; Will, Brian; Ruggeri, Kai

    2017-01-01

    Aircraft noise increases the risk of cardiovascular diseases and mental illness. The allowable limit for sound in the vicinity of an airport is 65 decibels (dB) averaged over a 24-h ‘day and night’ period (DNL) in the United States. We evaluate the trade-off between the cost and the health benefits of changing the regulatory DNL level from 65 dB to 55 dB using a Markov model. The study used LaGuardia Airport (LGA) as a case study. In compliance with 55 dB allowable limit of aircraft noise, sound insulation would be required for residential homes within the 55 dB to 65 dB DNL. A Markov model was built to assess the cost-effectiveness of installing sound insulation. One-way sensitivity analyses and Monte Carlo simulation were conducted to test uncertainty of the model. The incremental cost-effectiveness ratio of installing sound insulation for residents exposed to airplane noise from LGA was $11,163/QALY gained (95% credible interval: cost-saving and life-saving to $93,054/QALY gained). Changing the regulatory standard for noise exposure around airports from 65 dB to 55 dB comes at a very good value. PMID:29207473

  2. The Cost-Effectiveness of Lowering Permissible Noise Levels Around U.S. Airports.

    PubMed

    Jiao, Boshen; Zafari, Zafar; Will, Brian; Ruggeri, Kai; Li, Shukai; Muennig, Peter

    2017-12-02

    Aircraft noise increases the risk of cardiovascular diseases and mental illness. The allowable limit for sound in the vicinity of an airport is 65 decibels (dB) averaged over a 24-h 'day and night' period (DNL) in the United States. We evaluate the trade-off between the cost and the health benefits of changing the regulatory DNL level from 65 dB to 55 dB using a Markov model. The study used LaGuardia Airport (LGA) as a case study. In compliance with 55 dB allowable limit of aircraft noise, sound insulation would be required for residential homes within the 55 dB to 65 dB DNL. A Markov model was built to assess the cost-effectiveness of installing sound insulation. One-way sensitivity analyses and Monte Carlo simulation were conducted to test uncertainty of the model. The incremental cost-effectiveness ratio of installing sound insulation for residents exposed to airplane noise from LGA was $11,163/QALY gained (95% credible interval: cost-saving and life-saving to $93,054/QALY gained). Changing the regulatory standard for noise exposure around airports from 65 dB to 55 dB comes at a very good value.

  3. Business Case Analysis of Prototype Fabrication Division Recapitalization Plan. Summary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Booth, Steven Richard; Benson, Faith Ann; Dinehart, Timothy Grant

    Business case studies were completed to support procurement of new machines and capital equipment in the Prototype Fabrication (PF) Division SM-39 and TA-03-0102 machine shops. Economic analysis was conducted for replacing the Mazak 30Y Mill-Turn Machine in SM-39, the Haas Vertical CNC Mill in Building 102, and the Hardinge Q10/65-SP Lathe in SM-39. Analysis was also conducted for adding a NanoTech Lathe in Building 102 and a new electrical discharge machine (EDM) in SM-39 to augment current capabilities. To determine the value of switching machinery, a baseline scenario was compared with a future scenario where new machinery was purchased andmore » installed. Costs and benefits were defined via interviews with subject matter experts.« less

  4. Desk-top publishing using IBM-compatible computers.

    PubMed

    Grencis, P W

    1991-01-01

    This paper sets out to describe one Medical Illustration Departments' experience of the introduction of computers for desk-top publishing. In this particular case, after careful consideration of all the options open, an IBM-compatible system was installed rather than the often popular choice of an Apple Macintosh.

  5. 7 CFR 1755.3 - Field trials.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... installations of the materials or equipment in closely monitored situations designed to determine, to RUS's... concepts untried within the telephone industry is defined as “an experiment” and shall be handled as a special case using procedures considered appropriate by RUS to meet the individual experiment. (b) To...

  6. 30 CFR 250.292 - What must the DWOP contain?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Information Deepwater Operations Plans (dwop) § 250.292 What must the DWOP contain? You must include the following information in your DWOP: (a) A description and schematic of the typical wellbore, casing, and completion; (b) Structural design, fabrication, and installation information for each surface system...

  7. 40 CFR 264.254 - Monitoring and inspection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... in the case of existing portions of piles exempt from § 264.251(a)) and cover systems (e.g., membranes, sheets, or coatings) must be inspected for uniformity, damage, and imperfections (e.g., holes, cracks, thin spots, or foreign materials). Immediately after construction or installation: (1) Synthetic...

  8. 40 CFR 264.254 - Monitoring and inspection.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... in the case of existing portions of piles exempt from § 264.251(a)) and cover systems (e.g., membranes, sheets, or coatings) must be inspected for uniformity, damage, and imperfections (e.g., holes, cracks, thin spots, or foreign materials). Immediately after construction or installation: (1) Synthetic...

  9. 40 CFR 264.254 - Monitoring and inspection.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... in the case of existing portions of piles exempt from § 264.251(a)) and cover systems (e.g., membranes, sheets, or coatings) must be inspected for uniformity, damage, and imperfections (e.g., holes, cracks, thin spots, or foreign materials). Immediately after construction or installation: (1) Synthetic...

  10. 40 CFR 264.254 - Monitoring and inspection.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... in the case of existing portions of piles exempt from § 264.251(a)) and cover systems (e.g., membranes, sheets, or coatings) must be inspected for uniformity, damage, and imperfections (e.g., holes, cracks, thin spots, or foreign materials). Immediately after construction or installation: (1) Synthetic...

  11. 40 CFR 264.254 - Monitoring and inspection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... in the case of existing portions of piles exempt from § 264.251(a)) and cover systems (e.g., membranes, sheets, or coatings) must be inspected for uniformity, damage, and imperfections (e.g., holes, cracks, thin spots, or foreign materials). Immediately after construction or installation: (1) Synthetic...

  12. Technical-financial evaluation of rainwater harvesting systems in commercial buildings-case ase studies from Sonae Sierra in Portugal and Brazil.

    PubMed

    Sousa, Vitor; Silva, Cristina Matos; Meireles, Inês C

    2017-11-10

    Water is an essential and increasingly scarce resource that should be preserved. The evolution of the human population and communities has contributed to the global decrease of potable water availability and the reduction of its consumption is now compulsory. Rainwater harvesting systems (RWHS) are emerging as a viable alternative source for water consumption in non-potable uses. The present study aims to contribute to the promotion of water efficiency, focusing on the application of rainwater harvesting systems in commercial buildings, and comprises four stages: (i) development of a technical evaluation tool to aid the design of RWHS and support their financial evaluation; (ii) validation of the tool using operational data from an existing RWHS installed at Colombo Shopping Center, in Lisbon, Portugal; (iii) assessment of the sensibility of the technical evaluation tool results to the variation of the inputs, namely the precipitation and consumption, through a parametric analysis for the Colombo Shopping Center; and (iv) comparison of the performance and financial feasibility of hypothetical RWHS in two existing commercial buildings. The technical tool was applied to two Sonae Sierra's shopping centers, one in Portugal and one in Brazil. The installation of a 200-m 3 tank is advised for the first case study, allowing non-potable water savings of 60% but a payback period of about 19 years. In the Brazilian shopping, the implementation of a tank with a capacity ranging from 100 to 400 m 3 leads to non-potable savings between 20 and 50%, but with smaller payback period, under 2 years, due to the relatively lower investment costs and higher water fees.

  13. Work-related falls from ladders--a follow-back study of US emergency department cases.

    PubMed

    Lombardi, David A; Smith, Gordon S; Courtney, Theodore K; Brennan, Melanye J; Kim, Jae Young; Perry, Melissa J

    2011-11-01

    Ladder falls comprise 16% of all US workplace fall-related fatalities, and ladder use may be particularly hazardous among older workers. This follow-back study of injured workers from a nationally representative sample of US emergency departments (ED) focused on factors related to ladder falls in three domains of the work environment: work equipment, work practices, and worker-related factors. Risk factors for fractures, the most frequent and severe outcome, were also evaluated. Workers injured from a ladder fall, treated in one of the 65 participating ED in the occupational National Electronic Injury Surveillance System (NEISS) were asked to participate. The questionnaire included worker demographics, injury, ladder and work equipment and environment characteristics, work tasks, and activities. Multivariate logistic regression models estimated odds ratios and 95% confidence intervals of a work-related fracture. Three-hundred and six workers experiencing an injury from an--on average--7.5-foot-fall from a step, extension, or straight ladder were interviewed primarily from construction, installation, maintenance, and repair professions. Injuries were most frequently to the arm, elbow or shoulder; head, neck, or face with diagnoses were primarily fracture, strain, sprain, contusion or abrasion. Workers were most frequently standing or sitting on the ladder while installing, hanging an item, or performing a repair when they fell. Ladder movement was the mechanism in 40% of falls. Environmental conditions played a role in <10% of cases. There was a significant association between fracture risk and fall height while working on the ladder that was also influenced by older work age. This study advances knowledge of falls from ladders to support those who specify means and methods, select equipment, and plan, supervise, or manage the performance of employees working at heights.

  14. Effects of long-term exposure on LDEF fastener assemblies

    NASA Astrophysics Data System (ADS)

    Spear, Steve; Dursch, Harry

    1992-09-01

    This presentation summarizes the Systems Special Investigations Group (SIG) findings from testing and analysis of fastener assemblies used on the Long Duration Exposure Facility (LDEF) structure, the tray mounting clamps, and by the various experimenters. The LDEF deintegration team and several experimenters noted severe fastener damage and hardware removal difficulties during post-flight activities. The System SIG has investigated all reported instances, and in all cases examined to date, the difficulties were attributed to galling during installation or post-flight removal. To date, no evidence of coldwelding was found. Correct selection of materials and lubricants as well as proper mechanical procedures is essential to ensure successful on-orbit or post-flight installation and removal of hardware.

  15. Effects of long-term exposure on LDEF fastener assemblies

    NASA Technical Reports Server (NTRS)

    Spear, Steve; Dursch, Harry

    1992-01-01

    This presentation summarizes the Systems Special Investigations Group (SIG) findings from testing and analysis of fastener assemblies used on the Long Duration Exposure Facility (LDEF) structure, the tray mounting clamps, and by the various experimenters. The LDEF deintegration team and several experimenters noted severe fastener damage and hardware removal difficulties during post-flight activities. The System SIG has investigated all reported instances, and in all cases examined to date, the difficulties were attributed to galling during installation or post-flight removal. To date, no evidence of coldwelding was found. Correct selection of materials and lubricants as well as proper mechanical procedures is essential to ensure successful on-orbit or post-flight installation and removal of hardware.

  16. The Business Case for Fuel Cells: Delivering Sustainable Value

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Curtin, Sandra; Gangi, Jennifer

    This report, written and compiled by Argonne National Laboratory and the Fuel Cell and Hydrogen Energy Association with support from the Fuel Cell Technologies Office, provides an overview of private sector fuel cell installations at U.S. businesses as of December 31, 2016. Over the past few decades, hundreds of thousands of fuel cells have been installed around the world, for primary or backup power, as well as in various other applications including portable and emergency backup power. Fuel cells have also been deployed in other applications such as heat and electricity for homes and apartments, material handling, passenger vehicles, buses,more » and remote, off-grid sites.« less

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilkerson, Andrea M.; Davis, Robert G.

    The Yuma Sector Border Patrol Area is a high temperature and high solar radiation environment, providing an opportunity for the U.S. Department of Energy (DOE) to study thermal effects on outdoor light-emitting diode (LED) luminaires outside of the testing laboratory. Six LED luminaires were installed on three poles on the U.S.- Mexico border in February 2014 as part of a trial installation, which was detailed in a prior GATEWAY report.1 The initial trial installation was intended as a short - term test of six luminaires installed on three poles before proceeding with the complete installation of over 400 luminaires. Unexpectedmore » delays in the full installation have prevented the detailed evaluations initially planned, but the six installed LED luminaires continue to be monitored, and over the past year illuminance measurements were recorded initially in February 2014 and again in September 2014 at about 2500 hours of operation and in March 2015 at about 5000 hours of operation.« less

  18. The influence of installation angle of GGIs on full-tensor gravity gradient measurement

    NASA Astrophysics Data System (ADS)

    Wei, Hongwei; Wu, Meiping

    2018-03-01

    Gravity gradient plays an important role in many disciplines as a fundamental signal to reflect the information of the earth. Full-tensor gravity gradient measurement (FGGM) is an effective way to obtain the gravity gradient signal. In this paper, the installation mode of GGIs in FGGM is studied. It is expected that the accuracy of FGGM will be improved by optimizing the installation mode of GGIs. In addition, we analysed the relationship between GGIs’ installation angle and FGGM by establishing the measurement model of FGGM. Then the following conclusions was proved that there was no relationship between GGIs’ installation angle and the measurement result. This conclusion showed that there was no optimal angle for the GGIs’ installation in FGGM, and the installation angle only need to satisfy the relationship shown in the conclusion section of this paper. Finally, this conclusion was demonstrated by computer simulations.

  19. An Automatic System of Testing the Best Stress of Installation for Semiconductor Refrigeration Piece

    NASA Astrophysics Data System (ADS)

    Chen, Hongyan; Song, Ping

    Concerning the problems of the impact on the factors of installation about semiconductor refrigeration piece are rarely studied in China and abroad, a reasonable structure of test device is designed, using stepper motor to test the temperature of the cold surface under different stress of installation to get the best stress of installation for the semiconductor refrigeration piece. Experiments shows that the system is of good noise immunity, high controlling and measuring precision.

  20. 46 CFR 120.372 - Equipment and conductor grounding.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Equipment and conductor grounding. 120.372 Section 120... INSTALLATION Power Sources and Distribution Systems § 120.372 Equipment and conductor grounding. (a) All... together to a common ground by a normally non-current carrying conductor. Metallic cases of instruments and...

  1. 46 CFR 120.372 - Equipment and conductor grounding.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Equipment and conductor grounding. 120.372 Section 120... INSTALLATION Power Sources and Distribution Systems § 120.372 Equipment and conductor grounding. (a) All... together to a common ground by a normally non-current carrying conductor. Metallic cases of instruments and...

  2. Legal Issues Affecting Faculty and Administration in Higher Education.

    ERIC Educational Resources Information Center

    Peach, Larry E.; Reddick, Thomas L.

    Legal aspects of college teaching and administration are discussed. The faculty and college are liable by tort law for students in three ways: intentional acts or interference, strict liability, and negligence. Intentional acts include improperly installed or dangerous equipment, while strict liability cases usually occur where fault is not…

  3. 47 CFR 74.432 - Licensing requirements and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... authorized to establish standby circuits from places where official broadcasts may be made during times of... unattended in accordance with the following: (1) The station must be designed, installed, and protected so...) In cases where a series of broadcasts are to be made from the same location, portable or mobile...

  4. 47 CFR 74.432 - Licensing requirements and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... authorized to establish standby circuits from places where official broadcasts may be made during times of... unattended in accordance with the following: (1) The station must be designed, installed, and protected so...) In cases where a series of broadcasts are to be made from the same location, portable or mobile...

  5. 47 CFR 74.432 - Licensing requirements and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... authorized to establish standby circuits from places where official broadcasts may be made during times of... unattended in accordance with the following: (1) The station must be designed, installed, and protected so...) In cases where a series of broadcasts are to be made from the same location, portable or mobile...

  6. 47 CFR 74.432 - Licensing requirements and procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... authorized to establish standby circuits from places where official broadcasts may be made during times of... unattended in accordance with the following: (1) The station must be designed, installed, and protected so...) In cases where a series of broadcasts are to be made from the same location, portable or mobile...

  7. 32 CFR 775.6 - Planning considerations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., installation, and operation of utility (e.g., water, sewer, electrical) and communication systems (e.g., data... systems, and/or facilities; (37) Decisions to close facilities, decommission equipment, and/or temporarily... environment. The agency decision in the case of an EIS is reflected in a ROD. (b) Where a proposed major...

  8. 32 CFR 775.6 - Planning considerations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., installation, and operation of utility (e.g., water, sewer, electrical) and communication systems (e.g., data... systems, and/or facilities; (37) Decisions to close facilities, decommission equipment, and/or temporarily... environment. The agency decision in the case of an EIS is reflected in a ROD. (b) Where a proposed major...

  9. In-Soil and Down-Hole Soil Water Sensors: Characteristics for Irrigation Management

    USDA-ARS?s Scientific Manuscript database

    The past use of soil water sensors for irrigation management was variously hampered by high cost, onerous regulations in the case of the neutron probe (NP), difficulty of installation or maintenance, and poor accuracy. Although many sensors are now available, questions of their utility still abound....

  10. In-Situ Air Sparaing: Engineering and Design

    DTIC Science & Technology

    2008-01-31

    Construction Materials. Although PVC casing is commonly used, flexible or rigid polyethylene pipe may be more efficient for certain excavation methods, such as...depth, etc.) Piping insulation/ heat tape installed Piping flushed/cleaned/pressure tested Subsurface as-built equipment...4-4 Figure 4-2 Pilot-Scale Piping and Instrumentation Diagram

  11. The Case for Authentic Tasks in Content Literacy

    ERIC Educational Resources Information Center

    Parsons, Seth A.; Ward, Allison E.

    2011-01-01

    Motivation, academic vocabulary, and the role of teachers have been themes of previous Content Literacy columns. In this installment, we suggest that the tasks, or assignments, students complete are an important aspect of content literacy because they influence students' understandings of content and reading. Additionally, we demonstrate how…

  12. 76 FR 6088 - Installed Systems and Equipment for Use by the Flightcrew

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-03

    ... requirements proposed here with the intent of achieving that balance. General Discussion of the Proposal..., ``General requirements.'' Under that section, the FAA is charged with prescribing regulations and minimum... appropriate balance is needed among them. There have been cases in the past where design characteristics known...

  13. 14 CFR 121.279 - Control of engine rotation.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Control of engine rotation. 121.279 Section... REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.279 Control... case of turbine engine installations, a means of stopping the rotation need be provided only if the...

  14. 16 CFR 1211.16 - UL marking requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... will be readily visible—after installation, in the case of a permanently connected appliance—with: (1... shall be included unless the full-load power factor is 80 percent or more, or, for a cord-connected... to identify the accessory intended to be connected to the terminals or connectors. The accessory...

  15. 14 CFR 23.1325 - Static pressure system.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... the correlation between air pressure in the static pressure system and true ambient atmospheric static... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Static pressure system. 23.1325 Section 23...: Installation § 23.1325 Static pressure system. (a) Each instrument provided with static pressure case...

  16. 14 CFR 23.1325 - Static pressure system.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the correlation between air pressure in the static pressure system and true ambient atmospheric static... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Static pressure system. 23.1325 Section 23...: Installation § 23.1325 Static pressure system. (a) Each instrument provided with static pressure case...

  17. 14 CFR 23.1325 - Static pressure system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... the correlation between air pressure in the static pressure system and true ambient atmospheric static... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Static pressure system. 23.1325 Section 23...: Installation § 23.1325 Static pressure system. (a) Each instrument provided with static pressure case...

  18. 14 CFR 23.1325 - Static pressure system.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... the correlation between air pressure in the static pressure system and true ambient atmospheric static... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Static pressure system. 23.1325 Section 23...: Installation § 23.1325 Static pressure system. (a) Each instrument provided with static pressure case...

  19. Testing and Modeling of a 3-MW Wind Turbine Using Fully Coupled Simulation Codes (Poster)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LaCava, W.; Guo, Y.; Van Dam, J.

    This poster describes the NREL/Alstom Wind testing and model verification of the Alstom 3-MW wind turbine located at NREL's National Wind Technology Center. NREL,in collaboration with ALSTOM Wind, is studying a 3-MW wind turbine installed at the National Wind Technology Center(NWTC). The project analyzes the turbine design using a state-of-the-art simulation code validated with detailed test data. This poster describes the testing and the model validation effort, and provides conclusions about the performance of the unique drive train configuration used in this wind turbine. The 3-MW machine has been operating at the NWTC since March 2011, and drive train measurementsmore » will be collected through the spring of 2012. The NWTC testing site has particularly turbulent wind patterns that allow for the measurement of large transient loads and the resulting turbine response. This poster describes the 3-MW turbine test project, the instrumentation installed, and the load cases captured. The design of a reliable wind turbine drive train increasingly relies on the use of advanced simulation to predict structural responses in a varying wind field. This poster presents a fully coupled, aero-elastic and dynamic model of the wind turbine. It also shows the methodology used to validate the model, including the use of measured tower modes, model-to-model comparisons of the power curve, and mainshaft bending predictions for various load cases. The drivetrain is designed to only transmit torque to the gearbox, eliminating non-torque moments that are known to cause gear misalignment. Preliminary results show that the drivetrain is able to divert bending loads in extreme loading cases, and that a significantly smaller bending moment is induced on the mainshaft compared to a three-point mounting design.« less

  20. CUBES: cassegrain U-band Brazil-ESO spectrograph

    NASA Astrophysics Data System (ADS)

    Barbuy, B.; Bawden Macanhan, V.; Bristow, P.; Castilho, B.; Dekker, H.; Delabre, B.; Diaz, M.; Gneiding, C.; Kerber, F.; Kuntschner, H.; La Mura, G.; Maciel, W.; Meléndez, J.; Pasquini, L.; Pereira, C. B.; Petitjean, P.; Reiss, R.; Siqueira-Mello, C.; Smiljanic, R.; Vernet, J.

    2014-11-01

    CUBES is a high-efficiency, medium-resolution ( R˜20,000) ground based UV (300-400 nm) spectrograph, to be installed in the cassegrain focus of one of ESO's VLT unit telescopes in 2017/18. The CUBES project is a joint venture between ESO and IAG/USP, and LNA/MCTI. CUBES will provide access to a wealth of new and relevant information for stellar as well as extragalactic sources. Main science cases include the study of beryllium and heavy elements in metal-poor stars, the direct determination of carbon, nitrogen and oxygen abundances by study of molecular bands in the UV range, as well as the study of active galactic nuclei and the quasar absorption lines. With a streamlined modern instrument design, high efficiency dispersing elements and UV-sensitive detectors, it will give a significant gain in sensitivity over existing ground based medium-high resolution spectrographs, enabling vastly increased sample sizes accessible to the astronomical community. We present here a brief overview of the project including the status, science cases and a discussion of the design options.

  1. Campaign for Levitation in LDX

    NASA Astrophysics Data System (ADS)

    Garnier, D. T.; Hansen, A. K.; Mauel, M. E.; Ortiz, E. E.; Boxer, A. C.; Ellsworth, J. L.; Karim, I.; Kesner, J.; Michael, P. C.; Zhukovsky, A.

    2006-10-01

    In the past year, preparations have been made for the first flight of the Levitated Dipole Experiment (LDX). LDX, which consists of a 560 kg superconducting coil floating within a 5 m diameter vacuum chamber, is designed to study fusion relevant plasmas confined in a dipole magnetic field. During the spring, a high temperature superconducting levitation coil was integrated into the LDX facility. Testing was undertaken to verify the thermal performance of the coil under expected levitation conditions. In addition, a real-time operating system digital control system was developed that will be used for the levitation control. In July, plasma experiments were conducted with all superconducting magnets in operation. While still supported, roughly 75% of the weight of the floating coil was magnetically lifted by the levitation coil above. A series of plasma experiments were conducted with the same magnetic geometry as will be the case during levitation. During August, the second generation launcher system will be installed. The launcher, which retracts beyond the plasma's last closed field lines during operation, is designed to safely catch the floating coil following an unexpected loss of control. After this installation, levitation experiments will commence.

  2. A speed limit compliance model for dynamic speed display sign.

    PubMed

    Ardeshiri, Anam; Jeihani, Mansoureh

    2014-12-01

    Violating speed limits is a major cause of motor vehicle crashes. Various techniques have been adopted to ensure that posted speed limits are obeyed by drivers. This study investigates the effect of dynamic speed display signs (DSDSs) on drivers' compliance with posted speed limit. An extensive speed data collection upstream of, adjacent to, and downstream of DSDS locations on multiple road classes with different speed limits (25, 35, and 45 mph) was performed short-term and long-term after DSDS installation. Conventional statistical analysis, regression models, and a Bayesian network were developed to assess the DSDS's effectiveness. General compliance with speed limit (upstream of the DSDS location), time of day, day of week, duration of DSDS operation, and distance from the DSDS location were significantly correlated with speed limit compliance adjacent to the DSDS. While compliance with the speed limit due to the DSDS increased by 5%, speed reduction occurred in 40% of the cases. Since drivers were likely to increase their speed after passing the DSDS, it should be installed on critical points supplemented with enforcement. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Boosting a Low-Cost Smart Home Environment with Usage and Access Control Rules.

    PubMed

    Barsocchi, Paolo; Calabrò, Antonello; Ferro, Erina; Gennaro, Claudio; Marchetti, Eda; Vairo, Claudio

    2018-06-08

    Smart Home has gained widespread attention due to its flexible integration into everyday life. Pervasive sensing technologies are used to recognize and track the activities that people perform during the day, and to allow communication and cooperation of physical objects. Usually, the available infrastructures and applications leveraging these smart environments have a critical impact on the overall cost of the Smart Home construction, require to be preferably installed during the home construction and are still not user-centric. In this paper, we propose a low cost, easy to install, user-friendly, dynamic and flexible infrastructure able to perform runtime resources management by decoupling the different levels of control rules. The basic idea relies on the usage of off-the-shelf sensors and technologies to guarantee the regular exchange of critical information, without the necessity from the user to develop accurate models for managing resources or regulating their access/usage. This allows us to simplify the continuous updating and improvement, to reduce the maintenance effort and to improve residents’ living and security. A first validation of the proposed infrastructure on a case study is also presented.

  4. Estimation of solar collector area for water heating in buildings of Malaysia

    NASA Astrophysics Data System (ADS)

    Manoj Kumar, Nallapaneni; Sudhakar, K.; Samykano, M.

    2018-04-01

    Solar thermal energy (STE) utilization for water heating at various sectorial levels became popular and still growing especially for buildings in the residential area. This paper aims to study and identify the solar collector area needed based on the user requirements in an efficient manner. A step by step mathematical approach is followed to estimate the area in Sq. m. Four different cases each having different hot water temperatures (45°, 50°C, 55°C, and 60°C) delivered by the solar water heating system (SWHS) for typical residential application at Kuala Lumpur City, Malaysia is analysed for the share of hot and cold water mix. As the hot water temperature levels increased the share of cold water mix is increased to satisfy the user requirement temperature, i.e. 40°C. It is also observed that as the share of hot water mix is reduced, the collector area can also be reduced. Following this methodology at the installation stage would help both the user and installers in the effective use of the solar resource.

  5. New Whole-House Solutions Case Study: Exterior Rigid Foam Insulation at the Edge of a Slab Foundation, Fresno, California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Exterior rigid foam insulation at the edge of the slab foundation was a unique feature for this low-load, unoccupied test house in a hot-dry climate and may be more appropriate for climates with higher heating loads. U.S. Department of Energy Building America research team IBACOS worked with National Housing Quality Award winner Wathen-Castanos Hybrid Homes, Inc., to assess the performance of this feature in a single-family detached ranch house with three bedrooms and two full bathrooms constructed on a slab-on-grade foundation in Fresno, California. One challenge during installation of the system was the attachment of the butyl flashing to themore » open framing. To solve this constructability issue, the team added a nailer to the base of the wall to properly attach and lap the flashing. In this strategy, R-7.5, 1.5-in.-thick extruded polystyrene was installed on the exterior of the slab for a modeled savings of 4,500 Btu/h on the heating load.« less

  6. Parental awareness and perception for correct use of child restraint systems and airbags in Brazil.

    PubMed

    Souza, Bruno Gonçalves Schröder E; Evangelista de Melo, Tiago; Pereira Lisboa, Tales; Bastos Miranda, Marcos; Schroder E Souza, Thiago Gonçalves; de Oliveira, Valdeci Manoel

    2017-02-17

    The objective of this study was to obtain information about the current knowledge and habits of parents who transport children in cars in Brazil. A cross-sectional survey was conducted using specifically designed self-report questionnaires to parents of children attending a private pediatric office in a town in southwest Brazil. Data were collected regarding children's age, gender, height, and weight and possession of an automobile child restraint system (CRS), its type, frequency and adequacy of use, and reasons for not possessing or not using the devices. Parents were asked whether their cars were equipped with airbags and about the use of the restraints in seats with airbags. We interviewed parents of 293 children transported in cars who met the criteria for use of a CRS. Children were younger than 1 year in 15.3% of the cases, between 1 and 4 years in 38.6%, and older than 4 in 46.1%. Cars were equipped with CRS in 78.5% of the cases, but in only 58% of the cases was the device proper for child's age and adequately installed in the seat. Among owners of the devices, 84.3% reported that they always used it. Reasons for infrequency were forgetting the device at home or in another car (6.4%), the child disliking the device (3.2%), or the false impression that the child was grown enough not to use it (3.2%)l 87.1% did not justify why they did not always use the CRS. Considering type of CRS, correct installation of the seat, and frequency of use, only 44.4% of children under 1 year, 69.9% of those 1 to 4 years, and 52.6% over age 4 were protected. Only 28.6% of the parents knew that children should never be positioned in a seat with active airbags. Considering appropriateness for age, correctness of installation (in the back seat in the correct orientation), and frequency of use, only 50.85% (149/293) of the children were reported as always protected with a CRS. Children between 1 and 4 years were more likely to always use a CRS in this Brazilian survey. We were also able to identify an important gap in the knowledge about airbags among parents. Further efforts are needed to correct those distortions.

  7. Investigation of a computer virus outbreak in the pharmacy of a tertiary care teaching hospital.

    PubMed

    Bailey, T C; Reichley, R M

    1992-10-01

    A computer virus outbreak was recognized, verified, defined, investigated, and controlled using an infection control approach. The pathogenesis and epidemiology of computer virus infection are reviewed. Case-control study. Pharmacy of a tertiary care teaching institution. On October 28, 1991, 2 personal computers in the drug information center manifested symptoms consistent with the "Jerusalem" virus infection. The same day, a departmental personal computer began playing "Yankee Doodle," a sign of "Doodle" virus infection. An investigation of all departmental personal computers identified the "Stoned" virus in an additional personal computer. Controls were functioning virus-free personal computers within the department. Cases were associated with users who brought diskettes from outside the department (5/5 cases versus 5/13 controls, p = .04) and with College of Pharmacy student users (3/5 cases versus 0/13 controls, p = .012). The detection of a virus-infected diskette or personal computer was associated with the number of 5 1/4-inch diskettes in the files of personal computers, a surrogate for rate of media exchange (mean = 17.4 versus 152.5, p = .018, Wilcoxon rank sum test). After education of departmental personal computer users regarding appropriate computer hygiene and installation of virus protection software, no further spread of personal computer viruses occurred, although 2 additional Stoned-infected and 1 Jerusalem-infected diskettes were detected. We recommend that virus detection software be installed on personal computers where the interchange of diskettes among computers is necessary, that write-protect tabs be placed on all program master diskettes and data diskettes where data are being read and not written, that in the event of a computer virus outbreak, all available diskettes be quarantined and scanned by virus detection software, and to facilitate quarantine and scanning in an outbreak, that diskettes be stored in organized files.

  8. Job analysis of maintenance-mechanic position for the nuclear power plant maintenance personnel reliability model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siegel, A.I.; Bartter, W.D.; Kopstein, F.F.

    1982-06-01

    The task list method of job survey was used. In collaboration with BWR and PWR personnel, a list of 107 tasks performed by maintenance mechanics was developed, grouped into: remove and install, test and repair, inspect and perform preventive maintenance, miscellaneous, communication, and report preparation. For each listed task, the questionnaire form inquired into: frequency of performance, task completion time, safety consequences of improper performance, and the amount of training required to perform the task proficiently. Scaled information was requested about seven abilities: (1) visual speed, accuracy, and recognition; (2) gross motor coordination; (3) fine manual dexterity; (4) strength andmore » stamina; (5) cognition; (6) memory; and (7) problem solving required for function completion. Survey forms were distributed to 27 nuclear power plants. Thirty-one maintenance mechanics representing 17 plants returned the completed forms. Frequency of performing tasks was bimodally distributed: (1) between once a year and once every six months, and (2) about once a week. More than half of the tasks have potential risk consequences if improperly performed. The five tasks with the greatest risk implications in the case of inadequate performance were: (1) remove and install reactor and dry-well heads, (2) test and repair reactor system components, (3) remove and install pressurizer mechanical relief valves, (4) test and repair pressurizer relief valves, (5) remove and install core spray pumps, seals, and valves. Hierarchically, the public risk associated with the various functions was: (1) remove and install, (2) test and repair, (3) preventive maintenance, (4) miscellaneous tasks, (5) communication, and (6) report preparation.« less

  9. Waste incineration, Part I: Technology.

    PubMed

    1990-02-01

    Based upon an overview of the technology of incineration and the nature of hospital waste, HHMM offers the following suggestions: Old retort or other excess air incinerators should be replaced regardless of age. Even if emissions control equipment and monitoring devices can be retrofitted, excess-air incinerators are no longer cost-effective in terms of capacity, fuel consumption, and heat recovery. Audit (or have a specialist audit) your waste stream thoroughly. Consult a qualified engineering company experienced in hospital installations to get a system specified as exactly as possible to your individual conditions and needs. Make sure that the capacity of your incinerator will meet projections for future use. Anticipate the cost of emissions control and monitoring devices whether your state currently requires them or not. Make sure that your incinerator installation is engineered to accept required equipment in the future. Develop a strong community relations program well in advance of committing to incinerator installation. Take a proactive position by inviting your neighbors in during the planning stages. Be sure the contract governing incinerator purchase and installation has a cancellation clause, preferably without penalties, in case community action or a change in state regulations makes installation and operation impractical. The technology is available to enable hospitals to burn waste effectively, efficiently, and safely. HHMM echoes the concerns of Frank Cross--that healthcare facilities, as well as regional incinerators and municipalities, show the same concern for environmental protection as for their bottom lines. When emissions are under control and heat is recovered, both the environment and the bottom line are healthier.

  10. Work-related injuries among union drywall carpenters in Washington State, 1989-2008.

    PubMed

    Schoenfisch, Ashley L; Lipscomb, Hester; Marshall, Steve; Cameron, Wilfred; Richardson, David; Casteel, Carri

    2013-10-01

    Drywall installers are at high-risk of work-related injury. Comprehensive descriptive epidemiology of injuries among drywall installers, particularly over time, is lacking. We identified worker-hours and reported and accepted workers' compensation (WC) claims for a 20-year (1989-2008) cohort of 24,830 Washington State union carpenters. Stratified by predominant type of work (drywall installation, other carpentry), work-related injury rates were examined over calendar time and by worker characteristics. Expert interviews provided contextual details. Drywall installers' injury rates, higher than those of other carpenters, declined substantially over this period by 73.6%. Common injury mechanisms were struck by/against, overexertion and falls. Drywall material was considered a contributing factor in 19.7% of injuries. One-third of these drywall material-related injuries resulted in paid lost time, compared to 19.4% of injuries from other sources. Rates of injury were particularly high among workers with 2 to <4 years in the union. Notable declines over time in rates of overexertion injury in which drywall material was a contributing factor were still observed after controlling for secular temporal trends. Experts highlighted changes over the past 20 years that improved both work safety and, in some cases, production. Declines in drywall installers' injury rates over time likely reflect, in part, enhanced workplace safety, including efforts to reduce overexertion hazards associated with handling drywall. Continued injury prevention efforts are needed, particularly for less tenured workers. Given the potential for under-reporting to WC, additional sources of health outcomes data may provide a more complete picture of workers' health. Copyright © 2013 Wiley Periodicals, Inc.

  11. New Opportunities for Cabled Ocean Observatories

    NASA Astrophysics Data System (ADS)

    Duennebier, F. K.; Butler, R.; Karl, D. M.; Roger, L. B.

    2002-12-01

    With the decommissioning of transoceanic telecommunications cables as they become obsolete or uneconomical, there is an opportunity to use these systems for ocean observatories. Two coaxial cables, TPC-1 and HAW-2 are currently in use for observatories, and another, ANZCAN, is scheduled to be used beginning in 2004 to provide a cabled observatory at Station ALOHA, north of Oahu. The ALOHA observatory will provide several Mb/s data rates and about 1 kW of power to experiments installed at Station ALOHA. Sensors can be installed either by wet mateable connection to a junction box on the ocean floor using an ROV, or by acoustic data link to the system. In either case real-time data will be provided to users over the Internet. A Small Experiment Module, to be first installed at the Hawaii-2 Observatory, and later at Station ALOHA, will provide relatively cheap and uncomplicated access to the observatories for relatively simple sensors. Within the next few years, the first electro-optical cables installed in the 1980's will be decommissioned and could be available for scientific use. These cables could provide long "extension cords" (thousands of km) with very high bandwidth and reasonable power to several observatories in remote locations in the ocean. While they could be used in-place, a more exciting scenario is to use cable ships to pick up sections of cable and move them to locations of higher scientific interest. While such moves would not be cheap, the costs would rival the cost of installation and maintenance of a buoyed observatory, with far more bandwidth and power available for science use.

  12. Installing plastic tubing to collect sugar maple sap

    Treesearch

    H. Clay Smith; Albert G., Jr. Snow; Albert G. Snow

    1972-01-01

    The research unit of the Northeastern Forest Experiment Station at Burlington, Vermont, has been doing research on methods of installing tubing since 1966. We have studied several ways of hanging tubing and have found that there are certain techniques to use if plastic tubing is to be installed and to operate successfully.

  13. The Influence of Vacuum Circuit Breakers and Different Motor Models on Switching Overvoltages in Motor Circuits

    NASA Astrophysics Data System (ADS)

    Wong, Cat S. M.; Snider, L. A.; Lo, Edward W. C.; Chung, T. S.

    Switching of induction motors with vacuum circuit breakers continues to be a concern. In this paper the influence on statistical overvoltages of the stochastic characteristics of vacuum circuit breakers, high frequency models of motors and transformers, and network characteristics, including cable lengths and network topology are evaluated and a general view of the overvoltages phenomena is presented. Finally, a real case study on the statistical voltage levels and risk-of-failure resulting from switching of a vacuum circuit breaker in an industrial installation in Hong Kong is presented.

  14. Dust mass concentrations from the UK volcanic ash lidar network compared with in-situ aircraft measurements

    NASA Astrophysics Data System (ADS)

    Osborne, Martin; Marenco, Franco; Adam, Mariana; Buxmann, Joelle; Haywood, Jim

    2018-04-01

    The Met Office has recently established a series of 10 lidar / sun-photometer installations across the UK, consolidating their ash / aerosol remote sensing capabilities [1]. In addition to this network, the Met Office have acquired the Civil Contingency Aircraft (MOCCA) which allows airborne in-situ measurements of ash / aerosol scattering and size-distributions. Two case studies are presented in which mass concentrations of Saharan dust are obtained remotely using lidar returns, and are then compared with those obtained in-situ. A thorough analysis of the mass concentration uncertainty will be provided at the conference.

  15. Flexible Case - Grain Interaction in Ballistic Weapon Systems. Volume I. Technical Accomplishments.

    DTIC Science & Technology

    1976-10-01

    Summary of Test Measurements for Motor No. 2 K-i Appendix I Software Documentation and User ’s Manual L-1 Multiplexor Driver Program for the F Varian...the - .4 case. Thus, any force applied to the steel pl ug causes a slight deflectionof the strain gaged element that can be interpreted as a stress...were extruded by manual pressure.The failure gages were installed in a similar manner with the exception that they were bonded in place with standard AGC

  16. Vapor port and groundwater sampling well

    DOEpatents

    Hubbell, Joel M.; Wylie, Allan H.

    1996-01-01

    A method and apparatus has been developed for combining groundwater monitoring wells with unsaturated-zone vapor sampling ports. The apparatus allows concurrent monitoring of both the unsaturated and the saturated zone from the same well at contaminated areas. The innovative well design allows for concurrent sampling of groundwater and volatile organic compounds (VOCs) in the vadose (unsaturated) zone from a single well, saving considerable time and money. The sample tubes are banded to the outer well casing during installation of the well casing.

  17. Vapor port and groundwater sampling well

    DOEpatents

    Hubbell, J.M.; Wylie, A.H.

    1996-01-09

    A method and apparatus have been developed for combining groundwater monitoring wells with unsaturated-zone vapor sampling ports. The apparatus allows concurrent monitoring of both the unsaturated and the saturated zone from the same well at contaminated areas. The innovative well design allows for concurrent sampling of groundwater and volatile organic compounds (VOCs) in the vadose (unsaturated) zone from a single well, saving considerable time and money. The sample tubes are banded to the outer well casing during installation of the well casing. 10 figs.

  18. Breakeven Prices for Photovoltaics on Supermarkets in the United States

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ong, S.; Clark, N.; Denholm, P.

    The photovoltaic (PV) breakeven price is the PV system price at which the cost of PV-generated electricity equals the cost of electricity purchased from the grid. This point is also called 'grid parity' and can be expressed as dollars per watt ($/W) of installed PV system capacity. Achieving the PV breakeven price depends on many factors, including the solar resource, local electricity prices, customer load profile, PV incentives, and financing. In the United States, where these factors vary substantially across regions, breakeven prices vary substantially across regions as well. In this study, we estimate current and future breakeven prices formore » PV systems installed on supermarkets in the United States. We also evaluate key drivers of current and future commercial PV breakeven prices by region. The results suggest that breakeven prices for PV systems installed on supermarkets vary significantly across the United States. Non-technical factors -- including electricity rates, rate structures, incentives, and the availability of system financing -- drive break-even prices more than technical factors like solar resource or system orientation. In 2020 (where we assume higher electricity prices and lower PV incentives), under base-case assumptions, we estimate that about 17% of supermarkets will be in utility territories where breakeven conditions exist at a PV system price of $3/W; this increases to 79% at $1.25/W (the DOE SunShot Initiative's commercial PV price target for 2020). These percentages increase to 26% and 91%, respectively, when rate structures favorable to PV are used.« less

  19. Analysis of the Earthquake Impact towards water-based fire extinguishing system

    NASA Astrophysics Data System (ADS)

    Lee, J.; Hur, M.; Lee, K.

    2015-09-01

    Recently, extinguishing system installed in the building when the earthquake occurred at a separate performance requirements. Before the building collapsed during the earthquake, as a function to maintain a fire extinguishing. In particular, the automatic sprinkler fire extinguishing equipment, such as after a massive earthquake without damage to piping also must maintain confidentiality. In this study, an experiment installed in the building during the earthquake, the water-based fire extinguishing saw grasp the impact of the pipe. Experimental structures for water-based fire extinguishing seismic construction step by step, and then applied to the seismic experiment, the building appears in the extinguishing of the earthquake response of the pipe was measured. Construction of acceleration caused by vibration being added to the size and the size of the displacement is measured and compared with the data response of the pipe from the table, thereby extinguishing water piping need to enhance the seismic analysis. Define the seismic design category (SDC) for the four groups in the building structure with seismic criteria (KBC2009) designed according to the importance of the group and earthquake seismic intensity. The event of a real earthquake seismic analysis of Category A and Category B for the seismic design of buildings, the current fire-fighting facilities could have also determined that the seismic performance. In the case of seismic design categories C and D are installed in buildings to preserve the function of extinguishing the required level of seismic retrofit design is determined.

  20. Experimental study of the structure of vapor phase during boiling of R134a on heat exchange surfaces of heat pump

    NASA Astrophysics Data System (ADS)

    Ustinov, D. A.; Sukhikh, A. A.; Sidenkov, D. V.; Ustinov, V. A.

    2017-10-01

    The heat supply by means of heat pumps is considered now as a rational method of local heating which can lead to economy of primary fuel. At use of low-potential heat, for example, the heat of a ground (5 … 18 °C) or ground waters (8 … 10°C) only small depressing of temperature of these sources (on 3 … 5°C) is possible that demands application of heat exchangers with intensified heatmass transfer surfaces. In thermal laboratory of TOT department the 200 W experimental installation has been developed for research of process of boiling of freon R134a. The principle of action of the installation consists in realisation of reverse thermodynamic cycle and consecutive natural measurement of characteristics of elements of surfaces of heat exchangers of real installations at boiling points of freon from-10°C to +10°C and condensing temperatures from 15°C to 50 °C. The evaporator casing has optical windows for control of process of boiling of freon on ribbed on technology of distorting cut tubes. Temperature measurement in characteristic points of a cycle is provided by copper-constantan thermocouples which by means of ADT are connected to the computer that allows treat results of measurements in a real time mode. The structure of a two-phase flow investigated by means of the optical procedure based on laser technique.

  1. Posthole Sensor Performance in the USArray Transportable Array - Results from Testing and Initial Deployments in Alaska and Canada

    NASA Astrophysics Data System (ADS)

    Frassetto, A.; Busby, R. W.; Hafner, K.; Sauter, A.; Woodward, R.

    2014-12-01

    To prepare for the deployment of EarthScope's USArray Transportable Array (TA) in Alaska and adjacent Canada over the next several years, IRIS has evaluated different strategies for emplacing posthole seismometers. The goal of this work has been to maintain or enhance a TA station's noise performance while reducing the weight and logistical considerations required for its installation. Motivating this research are developments in posthole broadband seismometer design and the unique conditions for operating in this region, where many potential sites are located on frost-fractured outcrops or underlain by permafrost, in either case only accessible by helicopter. Current emplacement methods use a portable rig to auger or hammer-drill a hole 2.5-5 meters deep, in unconsolidated materials and permafrost, or by diamond bit coring 1-3 meters into rock. These emplacements are used at new TA installations and upgrades to existing AK network stations, and we compare their performance to the lower-48 TA vault installations. Through July 2014 there are eight TA and six upgraded AK stations operating under USArray; including five since at least October 2012, providing a detailed record of seasonal and/or site-specific behavior. We also discuss testing of different downhole configurations for 13 stations deployed at Piñon Flat Observatory in California since April 2014. Station performance is presented and compared using probability density functions summed from hourly power spectral density calculations. These are computed for the continuous time series of seismic data recorded on each seismic channel. Our results show that the noise performance of seismometers in Alaska with cased- or core- hole installations sometimes exceeds that of the quietest TA stations in the lower-48, particularly for the horizontal channels at long periods. We analyze and discuss the performance of example stations, comparing to other nearby seismometers. We also examine the performance of AK stations before and after they have been converted from surface vault to posthole configuration. At Piñon Flat, different methods for packing the seismometer and clamping its cables within cased holes has guided development of field procedure. The new posthole emplacements generally improve upon the mean performance of the lower-48 TA vaults.

  2. Vehicle characteristics associated with LATCH use and correct use in real-world child restraint installations.

    PubMed

    Cicchino, Jessica B; Jermakian, Jessica S

    2015-06-01

    The objective of this study was to determine if vehicle features associated with LATCH ease-of-use in laboratory studies with volunteers predict LATCH use and misuse in real-world child restraint installations. Vehicle characteristics were extracted from prior surveys of more than 100 top-selling 2010-13 vehicles. Use and correct use of LATCH was determined from records of more than 14,000 child restraint installations in these vehicles that were inspected by child passenger safety technicians at Safe Kids car seat checkup events during 2010-12. Logistic regression was used to examine the association between vehicle features and use and correct use of lower anchors and top tethers, controlling for other relevant installation features. Lower anchors were more likely to be used and correctly used when the clearance angle around them was greater than 54°, the force required to attach them to the lower anchors was less than 178N, and their depth within the seat bight was less than 4cm. Restraints were more likely to be attached correctly when installed with the lower anchors than with the seat belt. After controlling for lower anchor use and other installation features, the likelihood of tether use and correct use in installations of forward-facing restraints was significantly higher when there was no hardware present that could potentially be confused with the tether anchor or when the tether anchor was located on the rear deck, which is typical in sedans. There is converging evidence from laboratory studies with volunteers and real-world child restraint installations that vehicle features are associated with correct LATCH use. Vehicle designs that improve the ease of installing child restraints with LATCH could improve LATCH use rates and reduce child restraint misuse. Copyright © 2015 Elsevier Ltd and National Safety Council. All rights reserved.

  3. A comparison of safety benefits of pedestrian countdown signals with and without pushbuttons in Michigan.

    PubMed

    Boateng, Richard Atta; Kwigizile, Valerian; Oh, Jun-Seok

    2018-04-11

    This study evaluated the safety impacts of PCSs with and without pushbuttons based on pedestrian crashes and pedestrian injuries in Michigan. This study used ten years of intersection data: five years before PCSs were installed and five years after they were installed, along with a comparison group, to evaluate the crash impacts of PCSs: at 107 intersections the PCS had a pushbutton and at 96 it did not. At these intersections, and at their comparison sites (where no PCS was installed), crash data (from 2004-2016) were examined, along with traffic and geometric characteristics, population, education and poverty levels data. Intersections where PCSs with pushbuttons have been installed showed a 29 percent reduction in total pedestrian crashes and a 30 percent reduction in fatal/injury pedestrian crashes. Further, when considering only pedestrians age 65 and below, these respective reductions are 33 and 35 percent. Intersections with PCSs but without pushbuttons did not show any significant change in any type of pedestrian crash. Although the Manual of Uniform Traffic Control Devices (FHWA, 2009) requires the use of PCSs at new traffic signal installations, this study suggests a safety benefit of installing PCSs with pushbutton at signals where a PCS without a pushbutton is present.

  4. Voltage dips at the terminals of wind power installations

    NASA Astrophysics Data System (ADS)

    Bollen, Math H. J.; Olguin, Gabriel; Martins, Marcia

    2005-07-01

    This article gives an overview of the kind of voltage dips that can be expected at the terminals of a wind power installation. The overview is based on the study of those dips at the terminals of industrial installations and provides a guideline for the testing of wind power installations against voltage dips. For voltage dips due to faults, a classification into different types is presented. Five types appear at the terminals of sensitive equipment and thus have to be included when testing the wind power installation against disturbances coming from the grid. A distinction is made between installations connected at transmission level and those connected at distribution level. For the latter the phase angle jump has to be considered. Dips due to other causes (motor, transformer and capacitor switching) are briefly discussed as well as the voltage recovery after a dip. Finally some thoughts are presented on the way in which voltage tolerance requirements should be part of the design process for wind power installations. Copyright

  5. Growth phenology of coast Douglas-fir seed sources planted in diverse environments.

    PubMed

    Gould, Peter J; Harrington, Constance A; St Clair, J Bradley

    2012-12-01

    The timing of periodic life cycle events in plants (phenology) is an important factor determining how species and populations will react to climate change. We evaluated annual patterns of basal-area and height growth of coast Douglas-fir (Pseudotusga menziesii var. menziesii (Mirb.) Franco) seedlings from four seed sources that were planted in four diverse environments as part of the Douglas-fir Seed-Source Movement Trial. Stem diameters and heights were measured periodically during the 2010 growing season on 16 open-pollinated families at each study installation. Stem diameters were measured on a subset of trees with electronic dendrometers during the 2010 and 2011 growing seasons. Trees from the four seed sources differed in phenology metrics that described the timing of basal-area and height-growth initiation, growth cessation and growth rates. Differences in the height-growth metrics were generally larger than differences in the basal-area growth metrics and differences among installations were larger than differences among seed sources, highlighting the importance of environmental signals on growth phenology. Variations in the height- and basal-area growth metrics were correlated with different aspects of the seed-source environments: precipitation in the case of height growth and minimum temperature in the case of basal-area growth. The detailed dendrometer measurements revealed differences in growth patterns between seed sources during distinct periods in the growing season. Our results indicate that multiple aspects of growth phenology should be considered along with other traits when evaluating adaptation of populations to future climates.

  6. Content management systems and E-commerce: a comparative case study

    NASA Astrophysics Data System (ADS)

    Al Rasheed, Amal A.; El-Masri, Samir D.

    2011-12-01

    The need for CMS's to create and edit e-commerce websites has increased with the growing importance of e-commerce. In this paper, the various features essential for e-commerce CMS's are explored. The aim of the paper was to find the best CMS solution for e-commerce which includes the best of both CMS and store management. Accordingly, we conducted a study on three popular open source CMS's for e-commerce: VirtueMart from Joomla!, Ubercart from Drupal, and Magento. We took into account features like hosting and installation, performance, support/community, content management, add on modules and functional features. We concluded with improvements that could be made in order to alleviate problems.

  7. Advanced automotive diesel engine system study

    NASA Technical Reports Server (NTRS)

    1983-01-01

    A conceptual study of an advanced automotive diesel engine is discussed. The engine concept selected for vehicle installation was a supercharged 1.4 liter, 4 cylinder spark assisted diesel of 14:1 compression ratio. A compounding unit consisting of a Lysholm compressor and expander is connected to the engine crankshaft by a belt drive. The inlet air charge is heated by the expander exhaust gas via a heat exchanger. Four levels of technology achievement on the selected engine concept were evaluated, from state-of-the-art to the ideal case. This resulted in the fuel economy increasing from 53.2 mpg to 81.7 mpg, and the 0-60 mph time decreasing from 17.6 seconds to 10.9 seconds.

  8. PET/MRI in cancer patients: first experiences and vision from Copenhagen.

    PubMed

    Kjær, Andreas; Loft, Annika; Law, Ian; Berthelsen, Anne Kiil; Borgwardt, Lise; Löfgren, Johan; Johnbeck, Camilla Bardram; Hansen, Adam Espe; Keller, Sune; Holm, Søren; Højgaard, Liselotte

    2013-02-01

    Combined PET/MRI systems are now commercially available and are expected to change the medical imaging field by providing combined anato-metabolic image information. We believe this will be of particular relevance in imaging of cancer patients. At the Department of Clinical Physiology, Nuclear Medicine & PET at Rigshospitalet in Copenhagen we installed an integrated PET/MRI in December 2011. Here, we describe our first clinical PET/MR cases and discuss some of the areas within oncology where we envision promising future application of integrated PET/MR imaging in clinical routine. Cases described include brain tumors, pediatric oncology as well as lung, abdominal and pelvic cancer. In general the cases show that PET/MRI performs well in all these types of cancer when compared to PET/CT. However, future large-scale clinical studies are needed to establish when to use PET/MRI. We envision that PET/MRI in oncology will prove to become a valuable addition to PET/CT in diagnosing, tailoring and monitoring cancer therapy in selected patient populations.

  9. 32 CFR 552.82 - Exercise of “off limits” authority.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 3 2014-07-01 2014-07-01 false Exercise of âoff limitsâ authority. 552.82 Section 552.82 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY MILITARY... Reservations § 552.82 Exercise of “off limits” authority. (a) In appropriate cases, installation commanders may...

  10. 32 CFR 552.82 - Exercise of “off limits” authority.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 3 2011-07-01 2009-07-01 true Exercise of âoff limitsâ authority. 552.82 Section 552.82 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY MILITARY... Reservations § 552.82 Exercise of “off limits” authority. (a) In appropriate cases, installation commanders may...

  11. 32 CFR 552.82 - Exercise of “off limits” authority.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 3 2013-07-01 2013-07-01 false Exercise of âoff limitsâ authority. 552.82 Section 552.82 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY MILITARY... Reservations § 552.82 Exercise of “off limits” authority. (a) In appropriate cases, installation commanders may...

  12. 32 CFR 552.82 - Exercise of “off limits” authority.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 3 2012-07-01 2009-07-01 true Exercise of âoff limitsâ authority. 552.82 Section 552.82 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY MILITARY... Reservations § 552.82 Exercise of “off limits” authority. (a) In appropriate cases, installation commanders may...

  13. 32 CFR 552.82 - Exercise of “off limits” authority.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 3 2010-07-01 2010-07-01 true Exercise of âoff limitsâ authority. 552.82 Section 552.82 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY MILITARY... Reservations § 552.82 Exercise of “off limits” authority. (a) In appropriate cases, installation commanders may...

  14. Measurement of soil creep by inclinometer

    Treesearch

    Robert R. Ziemer

    1977-01-01

    Abstract - Continued inclinometer measurements at borehole sites installed in 1964 in northern California suggest that previously reported rates of soil creep are excessively high. Upon analysis of 35 access casings located in forested and grassland sites, no consistent direction of soil movement could be detected. In addition, no significant rate of soil creep could...

  15. Power Purchase Agreements | Climate Neutral Research Campuses | NREL

    Science.gov Websites

    . Examples of how some research campuses have used PPAs are provided below. Power Purchase Agreements , primarily to implement on-site energy installations. The owner, in this case a research campus, is typically Power Purchase Agreements Research campuses can use power purchase agreements (PPAs), such as

  16. Knowledge Value Added (KVA) Methodology as a Tool for Measuring the Utilization of Knowledge Assets Aboard Marine Corps Installations

    DTIC Science & Technology

    2008-06-01

    make better technology investment decisions. C. FOLLOW-ON RESEARCH POTENTIAL Like most assets, knowledge is only valuable if it can be transmuted ...CID Agent Sexual Assault Investigations Training E5 5 Conduct preliminary investigation on referable cases 5811 Basic Military Police Intelligence In

  17. 75 FR 12315 - Pacific Gas and Electric Company; Diablo Canyon Independent Spent Fuel Storage Installation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-15

    ... cases to mail copies on electronic storage media. Participants may not submit paper copies of their... holidays. Participants who believe that they have a good cause for not submitting documents electronically..., such as social security numbers, home addresses, or home phone numbers in their filings, unless an NRC...

  18. 14 CFR 125.177 - Control of engine rotation.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Control of engine rotation. 125.177 Section... Requirements § 125.177 Control of engine rotation. (a) Except as provided in paragraph (b) of this section... flight. (b) In the case of turbine engine installations, a means of stopping rotation need be provided...

  19. 30 CFR 250.517 - Tubing and wellhead equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... pressure integrity and is otherwise suitable for its intended use. (b) In the event of prolonged operations... Manager. (c) When the tree is installed, you must equip wells to monitor for casing pressure according to... platform wells, the wellhead, all annuli (A, B, C, D, etc., annuli). (2) subsea wells, the tubing head, the...

  20. 14 CFR 29.1325 - Static pressure and pressure altimeter systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... between air pressure in the static pressure system and true ambient atmospheric static pressure is not... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Static pressure and pressure altimeter...: Installation § 29.1325 Static pressure and pressure altimeter systems. (a) Each instrument with static air case...

  1. 46 CFR 58.25-85 - Special requirements for tank vessels.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... must meet equivalent standards to the satisfaction of the Commanding Officer, Marine Safety Center. (d... installed are non-duplicated hydraulic and if— (1) The actuators comply with § 58.25-60; and (2) In case of... (e), (h), (i), and (j); (2) Ensure working access to machinery and controls in the steering-gear...

  2. 46 CFR 58.25-85 - Special requirements for tank vessels.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... must meet equivalent standards to the satisfaction of the Commanding Officer, Marine Safety Center. (d... installed are non-duplicated hydraulic and if— (1) The actuators comply with § 58.25-60; and (2) In case of... (e), (h), (i), and (j); (2) Ensure working access to machinery and controls in the steering-gear...

  3. 78 FR 51816 - Notice of Actions on Special Permit Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-21

    ... OtterBox, Fort transportation in commerce Collins, CO. of a lithium ion battery which is permanently installed in a cell phone case as ``Lithium batteries contained in equipment.'' (modes 1, 4, 5) Denied 11296.... transportation in commerce of certain damaged or defective lithium batteries. (modes 1, 2, 3) Emergency Special...

  4. 46 CFR 95.05-10 - Fixed fire extinguishing systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... in special cases: (1) A fixed foam system may be used in cargo tanks. (2) A water sprinkling system.... Alternately, the Commandant may permit the installation of an approved water sprinkler system or other... is contracted for on or after November 19, 1952, a fixed carbon dioxide, foam, or water spray system...

  5. 46 CFR 95.05-10 - Fixed fire extinguishing systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... in special cases: (1) A fixed foam system may be used in cargo tanks. (2) A water sprinkling system.... Alternately, the Commandant may permit the installation of an approved water sprinkler system or other... is contracted for on or after November 19, 1952, a fixed carbon dioxide, foam, or water spray system...

  6. 46 CFR 95.05-10 - Fixed fire extinguishing systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... in special cases: (1) A fixed foam system may be used in cargo tanks. (2) A water sprinkling system.... Alternately, the Commandant may permit the installation of an approved water sprinkler system or other... is contracted for on or after November 19, 1952, a fixed carbon dioxide, foam, or water spray system...

  7. 46 CFR 95.05-10 - Fixed fire extinguishing systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... in special cases: (1) A fixed foam system may be used in cargo tanks. (2) A water sprinkling system.... Alternately, the Commandant may permit the installation of an approved water sprinkler system or other... is contracted for on or after November 19, 1952, a fixed carbon dioxide, foam, or water spray system...

  8. 14 CFR 29.1325 - Static pressure and pressure altimeter systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...: Installation § 29.1325 Static pressure and pressure altimeter systems. (a) Each instrument with static air case... between air pressure in the static pressure system and true ambient atmospheric static pressure is not... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Static pressure and pressure altimeter...

  9. 14 CFR 29.1325 - Static pressure and pressure altimeter systems.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...: Installation § 29.1325 Static pressure and pressure altimeter systems. (a) Each instrument with static air case... between air pressure in the static pressure system and true ambient atmospheric static pressure is not... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Static pressure and pressure altimeter...

  10. 14 CFR 29.1325 - Static pressure and pressure altimeter systems.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...: Installation § 29.1325 Static pressure and pressure altimeter systems. (a) Each instrument with static air case... between air pressure in the static pressure system and true ambient atmospheric static pressure is not... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Static pressure and pressure altimeter...

  11. 14 CFR 29.1325 - Static pressure and pressure altimeter systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...: Installation § 29.1325 Static pressure and pressure altimeter systems. (a) Each instrument with static air case... between air pressure in the static pressure system and true ambient atmospheric static pressure is not... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Static pressure and pressure altimeter...

  12. Characterization of the Effect of Wing Surface Instrumentation on UAV Airfoil Performance

    NASA Technical Reports Server (NTRS)

    Ratnayake, Nalin A.

    2009-01-01

    Recently proposed flight research at NASA Dryden Flight Research Center (DFRC) has prompted study into the aerodynamic effects of modifications made to the surfaces of laminar airfoils. The research is focused on the high-aspect ratio, laminar-flow type wings commonly found on UAVs and other aircraft with a high endurance requirement. A broad range of instrumentation possibilities, such as structural, pressure, and temperature sensing devices may require the alteration of the airfoil outer mold line as part of the installation process. This study attempts to characterize the effect of installing this additiona1 instrumentation on key airfoil performance factors, such as transition location, lift and drag curves, and stall point. In particular, the general case of an airfoil that is channeled in the spanwise direction is considered, and the impact on key performance characteristics is assessed. Particular attention is focused on exploring the limits of channel depth and low-Reynolds number on performance and stall characteristics. To quantify the effect of increased skin friction due to premature transition caused by protruding or recessed instrumentation, two simplified, conservative scenarios are used to consider two potential sources of diaturbance: A) that leading edge alterations would cause linearly expanding areas (triangles) of turbulent flow on both surfaces of the wing upstream of the natural transition point, and B) that a channel or bump on the upper surface would trip turbulent flow across the whole upper surface upstream of the natural transition point. A potentially more important consideration than the skin friction drag increment is the change in overall airfoil performance due to the installation of instrumentation along most of the wingspan. To quantify this effect, 2D CFD simulations of the flow over a representative mid-span airfoil section were conducted in order to assess the change in lift and drag curves for the airfoil in the presence of disturbed flow due to the installed instrumentation. A discussion as to the impact on high-altitude and low-speed operation of this and similar aircraft is provided.

  13. Traumatic injury among drywall installers, 1992 to 1995.

    PubMed

    Chiou, S S; Pan, C S; Keane, P

    2000-11-01

    This study examined the traumatic-injury characteristics associated with one of the high-risk occupations in the construction industry--drywall installers--through an analysis of the traumatic-injury data obtained from the Bureau of Labor Statistics. An additional objective was to demonstrate a feasible and economic approach to identify risk factors associated with a specific occupation by using an existing database. An analysis of nonfatal traumatic injuries with days away from work among wage-and-salary drywall installers was performed for 1992 through 1995 using the Occupational Injury and Illness Survey conducted by the Bureau of Labor Statistics. Results from this study indicate that drywall installers are at a high risk of overexertion and falls to a lower level. More than 40% of the injured drywall installers suffered sprains, strains, and/or tears. The most frequently injured body part was the trunk. More than one-third of the trunk injuries occurred while handling solid building materials, mainly drywall. In addition, the database analysis used in this study is valid in identifying overall risk factors for specific occupations.

  14. Flow Simulation of Modified Duct System Wind Turbines Installed on Vehicle

    NASA Astrophysics Data System (ADS)

    Rosly, N.; Mohd, S.; Zulkafli, M. F.; Ghafir, M. F. Abdul; Shamsudin, S. S.; Muhammad, W. N. A. Wan

    2017-10-01

    This study investigates the characteristics of airflow with a flow guide installed and output power generated by wind turbine system being installed on a pickup truck. The wind turbine models were modelled by using SolidWorks 2015 software. In order to investigate the characteristic of air flow inside the wind turbine system, a computer simulation (by using ANSYS Fluent software) is used. There were few models being designed and simulated, one without the rotor installed and another two with rotor installed in the wind turbine system. Three velocities being used for the simulation which are 16.7 m/s (60 km/h), 25 m/s (90 km/h) and 33.33 m/s (120 km/h). The study proved that the flow guide did give an impact to the output power produced by the wind turbine system. The predicted result from this study is the velocity of the air inside the ducting system of the present model is better that reference model. Besides, the flow guide implemented in the ducting system gives a big impact on the characteristics of the air flow.

  15. Clinical and biological analysis in graftless maxillary sinus lift.

    PubMed

    Parra, Marcelo; Olate, Sergio; Cantín, Mario

    2017-08-01

    Maxillary sinus lift for dental implant installation is a well-known and versatile technique; new techniques are presented based on the physiology of intrasinus bone repair. The aim of this review was to determine the status of graftless maxillary sinus lift and analyze its foundations and results. A search was conducted of the literature between 1995 and 2015 in the Medline, ScienceDirect, and SciELO databases using the keywords "maxillary sinus lift," "blood clot," "graftless maxillary sinus augmentation," and "dental implant placement." Ten articles were selected for our analysis of this technique and its results. Despite the limited information, cases that were followed for at least six months and up to four years had a 90% success rate. Published techniques included a lateral window, elevation of the sinus membrane, drilling and dental implant installation, descent of the membrane with variations in the installation of the lateral wall access and suturing. The physiology behind this new bone formation response and the results of the present research were also discussed. We concluded that this is a promising and viable technique under certain inclusion criteria.

  16. Techniques for Embedding Instrumentation in Pressure Vessel Test Articles

    NASA Technical Reports Server (NTRS)

    Cornelius, Michael

    2006-01-01

    Many interesting structural and thermal events occur in materials that are housed within a surrounding pressure vessel. In order to measure the environment during these events and explore their causes instrumentation must be installed on or in the material. Transducers can be selected that are small enough to be embedded within the test material but these instruments must interface with an external system in order to apply excitation voltages and output the desired data. The methods for installing the instrumentation and creating an interface are complicated when the material is located in a case or housing containing high pressures and hot gases. Installation techniques for overcoming some of these difficulties were developed while testing a series of small-scale solid propellant and hybrid rocket motors at Marshall Space Flight Center. These techniques have potential applications in other test articles where data are acquired from materials that require containment due to the severe environment encountered during the test process. This severe environment could include high pressure, hot gases, or ionized atmospheres. The development of these techniques, problems encountered, and the lessons learned from the ongoing testing process are summarized.

  17. Detecting a Defective Casing Seal at the Top of a Bedrock Aquifer.

    PubMed

    Richard, Sandra K; Chesnaux, Romain; Rouleau, Alain

    2016-03-01

    An improperly sealed casing can produce a direct hydraulic connection between two or more originally isolated aquifers with important consequences regarding groundwater quantity and quality. A recent study by Richard et al. (2014) investigated a monitoring well installed in a fractured rock aquifer with a defective casing seal at the soil-bedrock interface. A hydraulic short circuit was detected that produced some leakage between the rock and the overlying deposits. A falling-head permeability test performed in this well showed that the usual method of data interpretation is not valid in this particular case due to the presence of a piezometric error. This error is the direct result of the preferential flow originating from the hydraulic short circuit and the subsequent re-equilibration of the piezometric levels of both aquifers in the vicinity of the inlet and the outlet of the defective seal. Numerical simulations of groundwater circulation around the well support the observed impact of the hydraulic short circuit on the results of the falling-head permeability test. These observations demonstrate that a properly designed falling-head permeability test may be useful in the detection of defective casing seals. © 2015, National Ground Water Association.

  18. Global cost analysis on adaptation to sea level rise based on RCP/SSP scenarios

    NASA Astrophysics Data System (ADS)

    Kumano, N.; Tamura, M.; Yotsukuri, M.; Kuwahara, Y.; Yokoki, H.

    2017-12-01

    Low-lying areas are the most vulnerable to sea level rise (SLR) due to climate change in the future. In order to adapt to SLR, it is necessary to decide whether to retreat from vulnerable areas or to install dykes to protect them from inundation. Therefore, cost- analysis of adaptation using coastal dykes is one of the most essential issues in the context of climate change and its countermeasures. However, few studies have globally evaluated the future costs of adaptation in coastal areas. This study tries to globally analyze the cost of adaptation in coastal areas. First, global distributions of projected inundation impacts induced by SLR including astronomical high tide were assessed. Economic damage was estimated on the basis of the econometric relationship between past hydrological disasters, affected population, and per capita GDP using CRED's EM-DAT database. Second, the cost of adaptation was also determined using the cost database and future scenarios. The authors have built a cost database for installed coastal dykes worldwide and applied it to estimating the future cost of adaptation. The unit costs of dyke construction will increase with socio-economic scenario (SSP) such as per capita GDP. Length of vulnerable coastline is calculated by identifying inundation areas using ETOPO1. Future cost was obtained by multiplying the length of vulnerable coastline and the unit cost of dyke construction. Third, the effectiveness of dyke construction was estimated by comparing cases with and without adaptation.As a result, it was found that incremental adaptation cost is lower than economic damage in the cases of SSP1 and SSP3 under RCP scenario, while the cost of adaptation depends on the durability of the coastal dykes.

  19. Acceptance testing for PACS: from methodology to design to implementation

    NASA Astrophysics Data System (ADS)

    Liu, Brent J.; Huang, H. K.

    2004-04-01

    Acceptance Testing (AT) is a crucial step in the implementation process of a PACS within a clinical environment. AT determines whether the PACS is ready for clinical use and marks the official sign off of the PACS product. Most PACS vendors have Acceptance Testing (AT) plans, however, these plans do not provide a complete and robust evaluation of the full system. In addition, different sites will have different special requirements that vendor AT plans do not cover. The purpose of this paper is to introduce a protocol for AT design and present case studies of AT performed on clinical PACS. A methodology is presented that includes identifying testing components within PACS, quality assurance for both functionality and performance, and technical testing focusing on key single points-of-failure within the PACS product. Tools and resources that provide assistance in performing AT are discussed. In addition, implementation of the AT within the clinical environment and the overall implementation timeline of the PACS process are presented. Finally, case studies of actual AT of clinical PACS performed in the healthcare environment will be reviewed. The methodology for designing and implementing a robust AT plan for PACS was documented and has been used in PACS acceptance tests in several sites. This methodology can be applied to any PACS and can be used as a validation for the PACS product being acquired by radiology departments and hospitals. A methodology for AT design and implementation was presented that can be applied to future PACS installations. A robust AT plan for a PACS installation can increase both the utilization and satisfaction of a successful implementation of a PACS product that benefits both vendor and customer.

  20. Residual Stress Measurements After Proof and Flight: ETP-0403

    NASA Technical Reports Server (NTRS)

    Webster, Ronald L..

    1997-01-01

    The intent of this testing was to evaluate the residual stresses that occur in and around the attachment details of a case stiffener segment that has been subjected to flight/recovery followed by proof loading. Not measured in this test were stresses relieved at joint disassembly due to out-of-round and interference effects, and those released by cutting the specimens out of the case segment. The test article was lightweight case stiffener segment 1U50715, S/N L023 which was flown in the forward stiffener position on flight SRM 14A and in the aft position on flight SRM24A. Both of these flights were flown with the 3 stiffener ring configuration. Stiffener L023 had a stiffener ring installed only on the aft stub in its first flight, and it had both rings installed on its second flight. No significant post flight damage was found on either flight. Finally, the segment was used on the DM-8 static test motor in the forward position. No stiffener rings were installed. It had only one proof pressurization prior to assignment to its first use, and it was cleaned and proof tested after each flight. Thus, the segment had seen 3 proof tests, two flight pressurizations, and two low intensity water impacts prior to manufacturing for use on DM-8. On DM-8 it received one static firing pressurization in the horizontal configuration. Residual stresses at the surface and in depth were evaluated by both the x-ray diffraction and neutron beam diffraction methods. The x-ray diffraction evaluations were conducted by Technology for Energy Corporation (TEC) at their facilities in Knoxville, TN. The neutron beam evaluations were done by Atomic Energy of Canada Limited (AECL) at the Chalk River Nuclear Laboratories in Ontario. The results showed general agreement with relatively high compressive residual stresses on the surface and moderate to low subsurface tensile residual stresses.

Top