21 CFR 888.5960 - Cast removal instrument.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cast removal instrument. 888.5960 Section 888.5960...) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5960 Cast removal instrument. (a) Identification. A cast removal instrument is an AC-powered, hand-held device intended to remove a cast from a...
Nath, Rahul K; Somasundaram, Chandra
2016-01-01
Assessment of surgical outcomes of biceps tendon lengthening (BTL) surgery in obstetric brachial plexus injury (OBPI) patients with elbow flexion contractures, who had unsuccessful serial casting. Serial casting and splinting have been shown to be effective in correcting elbow flexion contractures in OBPI. However, the possibilities of radial head dislocations and other complications have been reported in serial casting and splinting. Literature indicates surgical intervention when such nonoperative techniques and range-of-motion exercises fail. Here, we demonstrated a significant reduction of the contractures of the affected elbow and improvement in arm length to more normal after BTL in these patients, who had unsuccessful serial casting. Ten OBPI patients (6 girls and 4 boys) with an average age of 11.2 years (4-17.7 years) had BTL surgery after unsuccessful serial casting. Mean elbow flexion contracture was 40° before and 37° (average) after serial casting. Mean elbow flexion contracture was reduced to 8° (0°-20°) post-BTL surgical procedure with an average follow-up of 11 months. This was 75% improvement and statistically significant (P < .001) when compared to 7% insignificant (P = .08) improvement after serial casting. These OBPI patients in our study had 75% significant reduction in elbow flexion contractures and achieved an improved and more normal length of the affected arm after the BTL surgery when compared to only 7% insignificant reduction and no improvement in arm length after serial casting.
21 CFR 888.5940 - Cast component.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cast component. 888.5940 Section 888.5940 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5940 Cast component. (a) Identification. A cast component is a...
21 CFR 888.5940 - Cast component.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cast component. 888.5940 Section 888.5940 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5940 Cast component. (a) Identification. A cast component is a...
21 CFR 888.5940 - Cast component.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cast component. 888.5940 Section 888.5940 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5940 Cast component. (a) Identification. A cast component is a...
21 CFR 888.5980 - Manual cast application and removal instrument.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual cast application and removal instrument... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5980 Manual cast application and removal instrument. (a) Identification. A manual cast application and removal instrument is a...
Casting materials and their application in research and teaching.
Haenssgen, Kati; Makanya, Andrew N; Djonov, Valentin
2014-04-01
From a biological point of view, casting refers to filling of anatomical and/or pathological spaces with extraneous material that reproduces a three-dimensional replica of the space. Casting may be accompanied by additional procedures such as corrosion, in which the soft tissue is digested out, leaving a clean cast, or the material may be mixed with radiopaque substances to allow x-ray photography or micro computed topography (µCT) scanning. Alternatively, clearing of the surrounding soft tissue increases transparency and allows visualization of the casted cavities. Combination of casting with tissue fixation allows anatomical dissection and didactic surgical procedures on the tissue. Casting materials fall into three categories namely, aqueous substances (India ink, Prussian blue ink), pliable materials (gelatins, latex, and silicone rubber), or hard materials (methyl methacrylates, polyurethanes, polyesters, and epoxy resins). Casting has proved invaluable in both teaching and research and many phenomenal biological processes have been discovered through casting. The choice of a particular material depends inter alia on the targeted use and the intended subsequent investigative procedures, such as dissection, microscopy, or µCT. The casting material needs to be pliable where anatomical and surgical manipulations are intended, and capillary-passable for ultrastructural investigations.
Somasundaram, Chandra
2016-01-01
Objective: Assessment of surgical outcomes of biceps tendon lengthening (BTL) surgery in obstetric brachial plexus injury (OBPI) patients with elbow flexion contractures, who had unsuccessful serial casting. Background: Serial casting and splinting have been shown to be effective in correcting elbow flexion contractures in OBPI. However, the possibilities of radial head dislocations and other complications have been reported in serial casting and splinting. Literature indicates surgical intervention when such nonoperative techniques and range-of-motion exercises fail. Here, we demonstrated a significant reduction of the contractures of the affected elbow and improvement in arm length to more normal after BTL in these patients, who had unsuccessful serial casting. Methods and Patients: Ten OBPI patients (6 girls and 4 boys) with an average age of 11.2 years (4-17.7 years) had BTL surgery after unsuccessful serial casting. Results: Mean elbow flexion contracture was 40° before and 37° (average) after serial casting. Mean elbow flexion contracture was reduced to 8° (0°-20°) post-BTL surgical procedure with an average follow-up of 11 months. This was 75% improvement and statistically significant (P < .001) when compared to 7% insignificant (P = .08) improvement after serial casting. Conclusion: These OBPI patients in our study had 75% significant reduction in elbow flexion contractures and achieved an improved and more normal length of the affected arm after the BTL surgery when compared to only 7% insignificant reduction and no improvement in arm length after serial casting. PMID:27648115
21 CFR 888.5960 - Cast removal instrument.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cast removal instrument. 888.5960 Section 888.5960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5960 Cast removal instrument. (a) Identification...
21 CFR 888.5960 - Cast removal instrument.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cast removal instrument. 888.5960 Section 888.5960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5960 Cast removal instrument. (a) Identification...
21 CFR 888.5960 - Cast removal instrument.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cast removal instrument. 888.5960 Section 888.5960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5960 Cast removal instrument. (a) Identification...
21 CFR 888.5960 - Cast removal instrument.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cast removal instrument. 888.5960 Section 888.5960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5960 Cast removal instrument. (a) Identification...
Comparison of Growing Rod Instrumentation Versus Serial Cast Treatment for Early-Onset Scoliosis.
Johnston, Charles E; McClung, Anna M; Thompson, George H; Poe-Kochert, Connie; Sanders, James O
2013-09-01
A comparison of 2 methods of early-onset scoliosis treatment using radiographic measures and complication rates. To determine whether a delaying tactic (serial casting) has comparable efficacy to a surgical method (insertion of growing rod instrumentation [GRI]) in the initial phase of early-onset deformity management. Serial casts are used in experienced centers to delay operative management of curves of surgical magnitude (greater than 50°) in children up to age 6 years. A total of 27 casted patients from 3 institutions were matched with 27 patients from a multicenter database according to age (within 6 months of each other), curve magnitude (within 10° of each other), and diagnosis. Outcomes were compared according to major curve magnitude, spine length (T1-S1), duration and number of treatment encounters, and complications. There was no difference in age (5.5 years) or initial curve magnitude (65°) between groups, which reflects the accuracy of the matching process. Six pairs of patients had neuromuscular diagnoses, 11 had idiopathic deformities, and 10 had syndromic scoliosis. Growing rod instrumentation patients had smaller curves (45.9° vs. 64.9°; p = .002) at follow-up, but there was no difference in absolute spine length (GRI = 32.0 cm; cast = 30.6 cm; p = .26), even though GRI patients had been under treatment for a longer duration (4.5 vs. 2.4 years; p < .0001) and had undergone a mean of 5.5 lengthenings compared with 4.0 casts. Growing rod instrumentation patients had a 44% complication rate, compared with 1 cast complication. Of 27 casted patients, 15 eventually had operative treatment after a mean delay of 1.7 years after casting. Cast treatment is a valuable delaying tactic for younger children with early-onset scoliosis. Spine deformity is adequately controlled, spine length is not compromised, and surgical complications associated with early GRI treatment are avoided. Copyright © 2013 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.
21 CFR 888.5980 - Manual cast application and removal instrument.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Manual cast application and removal instrument. 888.5980 Section 888.5980 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5980 Manual cast application...
21 CFR 888.5980 - Manual cast application and removal instrument.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Manual cast application and removal instrument. 888.5980 Section 888.5980 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5980 Manual cast application...
21 CFR 888.5980 - Manual cast application and removal instrument.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Manual cast application and removal instrument. 888.5980 Section 888.5980 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5980 Manual cast application...
21 CFR 888.5980 - Manual cast application and removal instrument.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Manual cast application and removal instrument. 888.5980 Section 888.5980 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5980 Manual cast application...
NASA Astrophysics Data System (ADS)
Shen, Shuwei; Zhao, Zuhua; Wang, Haili; Han, Yilin; Dong, Erbao; Liu, Bin; Liu, Wendong; Cromeens, Barrett; Adler, Brent; Besner, Gail; Ray, William; Hoehne, Brad; Xu, Ronald
2016-03-01
Appropriate surgical planning is important for improved clinical outcome and minimal complications in many surgical operations, such as a conjoined twin separation surgery. We combine 3D printing with casting and assembling to produce a solid phantom of high fidelity to help surgeons for better preparation of the conjoined twin separation surgery. 3D computer models of individual organs were reconstructed based on CT scanned data of the conjoined twins. The models were sliced, processed, and converted to an appropriate format for Fused Deposition Modeling (FDM). The skeletons of the phantom were printed directly by FDM using Acrylonitrile-Butadiene-Styrene (ABS) material, while internal soft organs were fabricated by casting silicon materials of different compositions in FDM printed molds. The skeleton and the internal organs were then assembled with appropriate fixtures to maintain their relative positional accuracies. The assembly was placed in a FMD printed shell mold of the patient body for further casting. For clear differentiation of different internal organs, CT contrast agents of different compositions were added in the silicon cast materials. The produced phantom was scanned by CT again and compared with that of the original computer models of the conjoined twins in order to verify the structural and positional fidelity. Our preliminary experiments showed that combining 3D printing with casting is an effective way to produce solid phantoms of high fidelity for the improved surgical planning in many clinical applications.
After aesthetic rhinoplasty: new looks and psychological outlooks on post-surgical satisfaction.
Moses, S; Last, U; Mahler, D
1984-01-01
Thirty-four female patients who underwent rhinoplasty were followed through assessment of post-surgical satisfaction (pss), perception of subjective improvement, objective improvement (surgeon's ratings), and objective post-surgical nasal deformity. Assessments of pss and subjective improvement were obtained on 3 occasions: T1, 1 week after surgery, on cast removal; T2, 1 month after cast removal; and T3, 3 months after cast removal. The investigation was aimed at examination of the relationship of patients' subjective post-surgical appraisals of the operation with objective indices of outcome of rhinoplasty. Results indicated that at T1, pss is totally dissociated from objective outcome or its appraisal by the patient. At T2 an association between objective outcome and pss and subjective appraisal of outcome is evident, but seems to reflect the total reliance of the patients' judgment on surgeons' appraisals. At T3 a paradoxical trend is indicated: slim objective favorable outcomes correlate with high pss, while a considerable share of patients with whom a highly favorable outcome has been attained express relatively low pss. This paradoxical trend may be well understood when applying Cognitive Dissonance Theory. The whole pattern of results point again at highly complex and powerful psychological processes, some of them seemingly irrational, operating within patients when relating to rhinoplasty, a simple superficial surgical procedure.
McCrory, Emma; McGuinness, Niall Jp; Ulhaq, Aman
2018-06-01
To determine the reproducibility of Index of Orthognathic Functional Treatment Need (IOFTN) scores derived from plaster casts and their three-dimensional (3D) digital equivalents. Pilot study, prospective analytical. UK hospital orthodontic department. Thirty casts and their digital equivalents, representing the pre-treatment malocclusions of patients requiring orthodontic-orthognathic surgical treatment, were scored by four clinicians using IOFTN. Casts were scanned using a 3Shape digital scanner and 3D models produced using OrthoAnalyzer TM (3Shape Ltd, Copenhagen, Denmark). Examiners independently determined the IOFTN scores for the casts and digital models, to test their inter- and intra-operator reliability using weighted Kappa scores. Intra-operator agreement with IOFTN major categories (1-5: treatment need) was very good for plaster casts (0.83-0.98) and good-very good for digital models (0.78-0.83). Inter-operator agreement was moderate-very good for casts (0.58-0.82) and good-very good for digital models (0.65-0.92). Intra-operator agreement with IOFTN sub-categories (1-14: feature of malocclusion) was good-very good for casts (0.70-0.97) and digital models (0.80-0.94). Inter-operator agreement was moderate-good for casts (0.53-0.77); and moderate-very good for the digital models (0.58-0.90). Digital models are an acceptable alternative to plaster casts for examining the malocclusion of patients requiring combined orthodontic-orthognathic surgical treatment and determining treatment need.
Evans, Angela; Chowdhury, Mamun; Rana, Sohel; Rahman, Shariar; Mahboob, Abu Hena
2017-01-01
The management of congenital talipes equino varus ( clubfoot deformity ) has been transformed in the last 20 years as surgical correction has been replaced by the non-surgical Ponseti method. The Ponseti method, consists of corrective serial casting followed by maintenance bracing, and has been repeatedly demonstrated to give best results - regarded as the 'gold standard' treatment for paediatric clubfoot. To develop the study protocol Level 2 evidence was used to modify the corrective casting phase of the Ponseti method in children aged up to 12 months. Using Level 4 evidence, the percutaneous Achilles tenotomy (PAT) was performed using a 19-gauge needle instead of a scalpel blade, a technique found to reduce bleeding and scarring. A total of 123 children participated in this study; 88 male, 35 female. Both feet were affected in 67 cases, left only in 22 cases, right only in 34 cases. Typical clubfeet were found in 112/123 cases, six atypical, five syndromic. The average age at first cast was 51 days (13-240 days).The average number of casts applied was five (2-10 casts). The average number of days between the first cast and brace was 37.8 days (10-122 days), including 21 days in a post-PAT cast. Hence, average time of corrective casts was 17 days.Parents preferred the reduced casting time, and were less concerned about unseen skin wounds.PAT was performed in 103/123 cases, using the needle technique. All post tenotomy casts were in situ for three weeks. Minor complications occurred in seven cases - four cases had skin lesions, three cases disrupted casting phase. At another site, 452 PAT were performed using the needle technique. The 'fast cast' protocol Ponseti casting was successfully used in infants aged less than 8 months. Extended manual manipulation of two minutes was the essential modification. Parents preferred the faster treatment phase, and ability to closer observe the foot and skin. The treating physiotherapists preferred the 'fast cast' protocol, achieving better correction with less complication. The needle technique for PAT is a further improvement for the Ponseti method.
Shen, Shuwei; Wang, Haili; Xue, Yue; Yuan, Li; Zhou, Ximing; Zhao, Zuhua; Dong, Erbao; Liu, Bin; Liu, Wendong; Cromeens, Barrett; Adler, Brent; Besner, Gail; Xu, Ronald X
2017-09-08
Preoperative assessment of tissue anatomy and accurate surgical planning is crucial in conjoined twin separation surgery. We developed a new method that combines three-dimensional (3D) printing, assembling, and casting to produce anatomic models of high fidelity for surgical planning. The related anatomic features of the conjoined twins were captured by computed tomography (CT), classified as five organ groups, and reconstructed as five computer models. Among these organ groups, the skeleton was produced by fused deposition modeling (FDM) using acrylonitrile-butadiene-styrene. For the other four organ groups, shell molds were prepared by FDM and cast with silica gel to simulate soft tissues, with contrast enhancement pigments added to simulate different CT and visual contrasts. The produced models were assembled, positioned firmly within a 3D printed shell mold simulating the skin boundary, and cast with transparent silica gel. The produced phantom was subject to further CT scan in comparison with that of the patient data for fidelity evaluation. Further data analysis showed that the produced model reassembled the geometric features of the original CT data with an overall mean deviation of less than 2 mm, indicating the clinical potential to use this method for surgical planning in conjoined twin separation surgery.
Pediatric laryngeal simulator using 3D printed models: A novel technique.
Kavanagh, Katherine R; Cote, Valerie; Tsui, Yvonne; Kudernatsch, Simon; Peterson, Donald R; Valdez, Tulio A
2017-04-01
Simulation to acquire and test technical skills is an essential component of medical education and residency training in both surgical and nonsurgical specialties. High-quality simulation education relies on the availability, accessibility, and reliability of models. The objective of this work was to describe a practical pediatric laryngeal model for use in otolaryngology residency training. Ideally, this model would be low-cost, have tactile properties resembling human tissue, and be reliably reproducible. Pediatric laryngeal models were developed using two manufacturing methods: direct three-dimensional (3D) printing of anatomical models and casted anatomical models using 3D-printed molds. Polylactic acid, acrylonitrile butadiene styrene, and high-impact polystyrene (HIPS) were used for the directly printed models, whereas a silicone elastomer (SE) was used for the casted models. The models were evaluated for anatomic quality, ease of manipulation, hardness, and cost of production. A tissue likeness scale was created to validate the simulation model. Fleiss' Kappa rating was performed to evaluate interrater agreement, and analysis of variance was performed to evaluate differences among the materials. The SE provided the most anatomically accurate models, with the tactile properties allowing for surgical manipulation of the larynx. Direct 3D printing was more cost-effective than the SE casting method but did not possess the material properties and tissue likeness necessary for surgical simulation. The SE models of the pediatric larynx created from a casting method demonstrated high quality anatomy, tactile properties comparable to human tissue, and easy manipulation with standard surgical instruments. Their use in a reliable, low-cost, accessible, modular simulation system provides a valuable training resource for otolaryngology residents. N/A. Laryngoscope, 127:E132-E137, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Wiley, Marcel R; Riccio, Anthony I; Felton, Kevin; Rodgers, Jennifer A; Wimberly, Robert L; Johnston, Charles E
Quengel casting was introduced in 1922 for nonsurgical treatment of knee flexion contractures (KFC) associated with hemophilic arthropathy. It consists of an extension-desubluxation hinge fixed to a cast allowing for gradual correction of a flexion deformity while preventing posterior tibial subluxation. The purpose of this study is to report 1 center's experience with this technique for the treatment of pediatric KFC. A retrospective review was conducted over a 26-year period. All patients with KFC treated with Quengel casting were included. Demographic data, associated medical conditions, adjunctive soft tissue releases, complications, and the need for late surgical intervention were recorded. Tibiofemoral angle measurements in maximal extension were recorded at initiation and termination of casting, 1-year follow-up, and final follow-up. Success was defined as no symptomatic recurrence of KFC or need for subsequent surgery. Eighteen patients (26 knees) were treated for KFC with Quengel casting. Average age at initiation of casting was 8.1 years with average follow-up of 59.9 months. Fifteen knees (58%) underwent soft tissue releases before casting. An average of 1.5 casts per knee were applied over an average of 23.9 days. Average KFC before casting was 50.6 degrees (range, 15 to 100 degrees) which improved to 5.96 degrees (0 to 40 degrees) at cast removal (P<0.00001). Sixteen patients (22 knees) had 1-year follow-up or failed casting before 1 year. Of these, 11 knees (50%) had a successful outcome. Residual KFC of those treated successfully was 6.8 degrees (range, 0 to 30 degrees) at 1 year and 8.2 degrees (range, 0 to 30 degrees) at final follow-up, averaging 71.4 months (P=0.81). Of the 11 knees deemed failures, all had recurrence of deformity within an average of 1 year from cast removal. Surgical release before Quengel casting did not improve the chances for success (P=0.09). Quengel casting can improve pediatric KFC an average of 44.2 degrees with minimal complications. Although 50% of treated patients will demonstrate significant recurrence or need later surgery, the majority of those treated successfully have durable results at intermediate term follow-up. Level IV-therapeutic study.
ABSTRACTS OF RESEARCH REPORTS.
DENTISTRY, ABSTRACTS), TEETH, DISEASES, MOUTH, TRANSPLANTATION, HYGIENE, STERILIZATION, FLUORIDES, HISTOLOGY, SURGICAL IMPLANTATION, OXYTETRACYCLINE , GELATINS, CELLULOSE, CASTING, PROGRAMMED INSTRUCTION, TRAINING DEVICES
Collins, Ruaraidh; Sudlow, Alexis; Loizou, Constantinos; Loveday, David T; Smith, George
2018-04-01
The relative benefits of surgical and conservative treatment of Achilles tendon rupture are widely debated. With modern conservative management protocols, the re-rupture risk appears to fall to one similar to surgical repair with negligible loss of function. Conservative management typically employs a period of time in an equinus cast with sequential ankle dorsiflexion in a functional orthosis. The optimal duration of immobilisation and rate of dorsiflexion is unknown. We aimed to quantify the change in Achilles tendon approximation achieved in common immobilisation techniques to assist the design of rehabilitation protocols. Twelve fresh-frozen cadaveric specimens had 2.5cm of Achilles tendon excised. The gap between the tendon ends were measured via windowed full equinus casts and compared with functional boots with successively removed heel wedges. The greatest tendon apposition was achieved with the equinus cast. Each wedge removed decreased the reapproximation by approximately 5mm. This paper supports the early use of maximal equinus casting in early management of acute Achilles tendon ruptures. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Miller, Nancy H; Carry, Patrick M; Mark, Bryan J; Engelman, Glenn H; Georgopoulos, Gaia; Graham, Sue; Dobbs, Matthew B
2016-01-01
Despite being recognized as the gold standard in isolated clubfoot treatment, the Ponseti casting method has yielded variable results. Few studies have directly compared common predictors of treatment failure between institutions with high versus low failure rates. We asked: (1) is the provider's rigid adherence to the Ponseti method associated with a lower likelihood of unplanned clubfoot surgery, and (2) at the institution that did not adhere rigidly to Ponseti's principles, are any demographic or treatment-related factors associated with increased likelihood of unplanned clubfoot surgery? After institutional review board approval, a consecutive series of patients with a diagnosis of isolated clubfoot who underwent treatment between January 2003 and December 2007 were identified. At Institution 1, 91 of 133 patients met the eligibility criteria and were followed for a minimum of 2 years compared with 58 of 58 patients at Institution 2. At Institution 1, 16 providers managed care using a conservative casting approach based on the Ponseti method. However, treatment was adapted by the provider(s). At Institution 2, one orthopaedic surgeon managed care with strict adherence to the Ponseti method. Surgical indications at both institutions included the presence of a persistent equinovarus foot position while standing. A chart review was used to collect data related to proportion of patients undergoing unplanned additional treatment for deformity recurrences after Ponseti casting, demographics, and treatment patterns. The proportion of subjects who underwent unplanned major surgical intervention was greater (odds ratio [OR], 51.1; 95% CI, 6.8-384.0; p < 0.001) at Institution 1 (60 of 131, 47%) compared with Institution 2 (two of 91, 2%). There was no difference (p = 0.200) in the proportion of patients who underwent additional casting, repeat tendo Achilles lengthening, and/or anterior tibialis tendon transfer only (minor recurrence) at Institution 1 (nine of 131, 7%) compared with Institution 2 (11 of 91, 13%). At Institution 1, an increase in the number of revision casts (multiple vs no casts, hazard ratio [HR] = 3.9; 95% CI, 2.0-7.6; p < 0.001) and an increase in the number of cast-related complications (multiple vs no complications, HR = 2.8; 95% CI, 1.2-6.7; p = 0.019) were associated with increased risk of major surgery in the multivariate analysis. Rigid commitment to the Ponseti method in the conservative treatment of patients with isolated clubfoot was associated with a lower risk of subsequent unplanned surgical intervention. In addition, clubfoot treatment programs that use a care model that prioritizes continuity in care and dedication to the Ponseti method may decrease the proportion of patients who undergo unplanned surgical intervention. Level III, therapeutic study.
Ryan, Justin R; Chen, Tsinsue; Nakaji, Peter; Frakes, David H; Gonzalez, L Fernando
2015-11-01
Educational simulators provide a means for students and experts to learn and refine surgical skills. Educators can leverage the strengths of medical simulators to effectively teach complex and high-risk surgical procedures, such as placement of an external ventricular drain. Our objective was to develop a cost-effective, patient-derived medical simulacrum for cerebral lateral ventriculostomy. A cost-effective, patient-derived medical simulacrum was developed for placement of an external lateral ventriculostomy. Elastomeric and gel casting techniques were used to achieve realistic brain geometry and material properties. 3D printing technology was leveraged to develop accurate cranial properties and dimensions. An economical, gravity-driven pump was developed to provide normal and abnormal ventricular pressures. A small pilot study was performed to gauge simulation efficacy using a technology acceptance model. An accurate geometric representation of the brain was developed with independent lateral cerebral ventricular chambers. A gravity-driven pump pressurized the ventricular cavities to physiologic values. A qualitative study illustrated that the simulation has potential as an educational tool to train medical professionals in the ventriculostomy procedure. The ventricular simulacrum can improve learning in a medical education environment. Rapid prototyping and multi-material casting techniques can produce patient-derived models for cost-effective and realistic surgical training scenarios. Copyright © 2015 Elsevier Inc. All rights reserved.
Surgical Anatomy of the Gastrointestinal Tract and Its Vasculature in the Laboratory Rat
Vdoviaková, Katarína; Petrovová, Eva; Maloveská, Marcela; Krešáková, Lenka; Teleky, Jana; Elias, Mario Zefanias Joao; Petrášová, Darina
2016-01-01
The aim of this study was to describe and illustrate the morphology of the stomach, liver, intestine, and their vasculature to support the planning of surgical therapeutic methods in abdominal cavity. On adult Wistar rats corrosion casts were prepared from the arterial system and Duracryl Dental and PUR SP were used as a casting medium and was performed macroscopic anatomical dissection of the stomach, liver, and intestine was performed. The rat stomach was a large, semilunar shaped sac with composite lining. On the stomach was very marked fundus, which formed a blind sac (saccus cecus). The rat liver was divided into six lobes, but without gall bladder. Intestine of the rat was simple, but cecum had a shape as a stomach. The following variations were observed in the origin of the cranial mesenteric artery. On the corrosion cast specimens we noticed the presence of the anastomosis between middle colic artery (a. colica media) and left colic artery (a. colica sinistra). We investigated the second anastomosis between middle colic artery and left colic artery. The results of this study reveal that the functional anatomical relationship between the rat stomach, liver and intestine is important for the development of surgical research in human and veterinary medicine. PMID:26819602
Dias, Joseph; Brealey, Stephen; Choudhary, Surabhi; Cook, Liz; Costa, Matthew; Fairhurst, Caroline; Hewitt, Catherine; Hodgson, Stephen; Jefferson, Laura; Jeyapalan, Kanagaratnam; Keding, Ada; Leighton, Paul; Rangan, Amar; Richardson, Gerry; Rothery, Claire; Taub, Nicholas; Thompson, John; Torgerson, David
2016-06-04
A scaphoid fracture is the most common type of carpal fracture affecting young active people. The optimal management of this fracture is uncertain. When treated with a cast, 88 to 90 % of these fractures unite; however, for the remaining 10-12 % the non-union almost invariably leads to arthritis. The alternative is surgery to fix the scaphoid with a screw at the outset. We will conduct a randomised controlled trial (RCT) of 438 adult patients with a "clear" and "bicortical" scaphoid waist fracture on plain radiographs to evaluate the clinical effectiveness and cost-effectiveness of plaster cast treatment (with fixation of those that fail to unite) versus early surgical fixation. The plaster cast treatment will be immobilisation in a below elbow cast for 6 to 10 weeks followed by mobilisation. If non-union is confirmed on plain radiographs and/or Computerised Tomogram at 6 to 12 weeks, then urgent surgical fixation will be performed. This is being compared with immediate surgical fixation with surgeons using their preferred technique and implant. These treatments will be undertaken in trauma units across the United Kingdom. The primary outcome and end-point will be the Patient Rated Wrist Evaluation (a patient self-reported assessment of wrist pain and function) at 52 weeks and also measured at 6, 12, 26 weeks and 5 years. Secondary outcomes include an assessment of radiological union of the fracture; quality of life; recovery of wrist range and strength; and complications. We will also qualitatively investigate patient experiences of their treatment. Scaphoid fractures are an important public health problem as they predominantly affect young active individuals in the more productive working years of their lives. Non-union, if untreated, can lead to arthritis which can disable patients at a very young age. There is a rapidly increasing trend for immediate surgical fixation of these fractures but there is insufficient evidence from existing RCTs to support this. The SWIFFT Trial is a rigorously designed and adequately powered study which aims to contribute to the evidence-base to inform clinical decisions for the treatment of this common fracture in adults. The trial is registered with the International Standard Randomised Controlled Trial Register ( ISRCTN67901257 ). Date registration assigned was 13/02/2013.
[Neglected ipsilateral simultaneous ruptures of patellar and quadriceps tendon].
Karahasanoğlu, İlker; Yoloğlu, Osman; Kerimoğlu, Servet; Turhan, Ahmet Uğur
2015-01-01
Neglected patellar and quadriceps tendon rupture is a rare injury, but ipsilateral simultaneous patellar and quadriceps tendon rupture was not described in the literature to our knowledge. In this article, we report a 40-year-old healthy male patient with neglected ipsilateral patellar and quadriceps tendon ruptures treated by peroneus longus tendon autograft. Patient had received some conservative and surgical treatments for patellar fracture before applying to our clinic. After our treatment using peroneus longus autograft and interference nails, patient was immobilized for six weeks in cylindrical cast. Flexion exercises and full weight bearing were started after cast removal. Patient had no complaint at postoperative second year. Patient was a neglected case. Surgical repair and early rehabilitation enabled us to achieve a satisfactory outcome.
Reliability of implant surgical guides based on soft-tissue models.
Maney, Pooja; Simmons, David E; Palaiologou, Archontia; Kee, Edwin
2012-12-01
The purpose of this study was to determine the accuracy of implant surgical guides fabricated on diagnostic casts. Guides were fabricated with radiopaque rods representing implant positions. Cone beam computerized tomograms were taken with guides in place. Accuracy was evaluated using software to simulate implant placement. Twenty-two sites (47%) were considered accurate (13 of 24 maxillary and 9 of 23 mandibular sites). Soft-tissue models do not always provide sufficient accuracy for fabricating implant surgical guides.
The distribution of cataract surgery services in a public health eye care program in Nepal.
Marseille, E; Brand, R
1997-11-01
The cost-effectiveness of public health cataract programs in low-income countries has been well documented. Equity, another important dimension of program quality which has received less attention is analyzed here by comparisons of surgical coverage rates for major sub-groups within the intended beneficiary population of the Nepal blindness program (NBP). Substantial differences in surgical coverage were found between males and females and between different age groups of the same gender. Among the cataract blind, the surgical coverage of males was 70% higher than that of females. For both genders, the cataract blind over 55 received proportionately fewer services than younger people blind from cataract. Blind males aged 45-54 had a 500% higher rate of surgical coverage than blind males over 65. Blind females aged 35-44 had nearly a 600% higher rate of surgical coverage than blind females over 65. There was wide variation in overall surgical coverage between geographic zones, but little variation by terrain type, an indicator of the logistical difficulties in delivery of services. Members of the two highest caste groupings had somewhat lower surgical coverage than members of lower castes. Program managers should consider developing methods to increase services to women and to those over 65. Reaching these populations will become increasingly important as those most readily served receive surgery and members of the under-served groups form a growing portion of the remaining cataract backlog.
The University Münster Model Surgery System for Orthognathic Surgery. Part II -- KD-MMS.
Ehmer, Ulrike; Joos, Ulrich; Ziebura, Thomas; Flieger, Stefanie; Wiechmann, Dirk
2013-01-04
Model surgery is an integral part of the planning procedure in orthognathic surgery. Most concepts comprise cutting the dental cast off its socket. The standardized spacer plates of the KD-MMS provide for a non-destructive, reversible and reproducible means of maxillary and/or mandibular plaster cast separation. In the course of development of the system various articulator types were evaluated with regard to their capability to provide a means of realizing the concepts comprised of the KD-MMS. Special attention was dedicated to the ability to perform three-dimensional displacements without cutting of plaster casts. Various utilities were developed to facilitate maxillary displacement in accordance to the planning. Objectives of this development comprised the ability to implement the values established in the course of two-dimensional ceph planning. The system - KD-MMS comprises a set of hardware components as well as a defined procedure. Essential hardware components are red spacer and blue mounting plates. The blue mounting plates replace the standard yellow SAM mounting elements. The red spacers provide for a defined leeway of 8 mm for three-dimensional movements. The non-destructive approach of the KD-MMS makes it possible to conduct different model surgeries with the same plaster casts as well as to restore the initial, pre-surgical situation at any time. Thereby, surgical protocol generation and gnathologic splint construction are facilitated. The KD-MMS hardware components in conjunction with the defined procedures are capable of increasing efficiency and accuracy of model surgery and splint construction. In cases where different surgical approaches need to be evaluated in the course of model surgery, a significant reduction of chair time may be achieved.
Serial Derotational Casting in Idiopathic and Non-Idiopathic Progressive Early-Onset Scoliosis.
Gussous, Yazeed M; Tarima, Sergey; Zhao, Shi; Khan, Safdar; Caudill, Angela; Sturm, Peter; Hammerberg, Kim W
2015-05-01
Serial derotational casting has been used as a definitive treatment or as delaying strategy in progressive idiopathic (IS) and non-idiopathic (NIS) early-onset scoliosis (EOS). Retrospective chart and radiographic review of patients who underwent serial casting for progressive EOS between 2005 and 2012 at a single institution. A total of 74 consecutive patients entered serial cast treatment. Twenty-eight were currently being casted, 30 completed cast treatment and were converted to thoracolumbosacral orthosis (TLSO), 9 were treated surgically, 6 were lost to follow-up, and 1 had no further treatment. The researchers diagnosed IS in 41 patients; 33 had NIS. At presentation the IS group had an average Cobb angle (CA) of 49° and a rib vertebral angle difference (RVAD) of 37°. The NIS group had a CA of 51° (p = .69) and RVAD of 37° (p = .94). In patients currently being casted, 19 IS patients had a decreased CA, from 47° to 27°. The 9 NIS patients had a decreased CA, from 62° to 57° (p = .0002). Cobb angle improvement was significantly better in IS (p = .0005). In the TLSO group the 17 IS patients had a decreased average CA, from 46° to 18°, after serial casting and the 13 NIS patients decreased CA from 42° to 32°. Patients with IS had better improvement in CA than the NIS group (p < .001). At last follow-up, this was reduced to 11° in the IS group and maintained at 32° in the NIS. In the IS group, 5 of 41 patients were converted to growth constructs, and 4 of 26 in the NIS group. Casting initiated before age 2 years yielded better curve correction for IS (p < .01) compared with NIS. Progressive idiopathic scoliosis patients had better curve correction with casting than NIS patients. Casting in IS patients before age 24 months yielded better curve correction. Patients who required surgery had a higher age and Cobb angle at presentation than those who transitioned to a TLSO. The surgical group was observed for a similar duration of time and there was no significant statistical difference. Although RVAD is a predictor of progression in infantile IS, it did not show a predictive value in the response to casting of either the IS or NIS groups. Copyright © 2015 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.
Kim, Dae-Seung; Woo, Sang-Yoon; Yang, Hoon Joo; Huh, Kyung-Hoe; Lee, Sam-Sun; Heo, Min-Suk; Choi, Soon-Chul; Hwang, Soon Jung; Yi, Won-Jin
2014-12-01
Accurate surgical planning and transfer of the planning in orthognathic surgery are very important in achieving a successful surgical outcome with appropriate improvement. Conventionally, the paper surgery is performed based on a 2D cephalometric radiograph, and the results are expressed using cast models and an articulator. We developed an integrated orthognathic surgery system with 3D virtual planning and image-guided transfer. The maxillary surgery of orthognathic patients was planned virtually, and the planning results were transferred to the cast model by image guidance. During virtual planning, the displacement of the reference points was confirmed by the displacement from conventional paper surgery at each procedure. The results of virtual surgery were transferred to the physical cast models directly through image guidance. The root mean square (RMS) difference between virtual surgery and conventional model surgery was 0.75 ± 0.51 mm for 12 patients. The RMS difference between virtual surgery and image-guidance results was 0.78 ± 0.52 mm, which showed no significant difference from the difference of conventional model surgery. The image-guided orthognathic surgery system integrated with virtual planning will replace physical model surgical planning and enable transfer of the virtual planning directly without the need for an intermediate splint. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Onyx resorbtion with AVM recanalization after complete AVM obliteration.
Bauer, Andrew M; Bain, Mark D; Rasmussen, Peter A
2015-06-01
Brain arteriovenous malformations (BAVM) are some of the most complex lesions treated by clinical neuroscientists. The recent publication of the ARUBA trial, showing higher complication rates with treatment compared with the natural history over a short period of follow-up, puts even more pressure on the physician to achieve complete BAVM eradication without complication. These lesions are often treated by multimodality therapy with some combination of endovascular embolization, radiosurgery, and microsurgical resection; however, multimodality therapy involves the additive risk of procedural complication with each procedure. While surgical resection has long been accepted as monotherapy with good cure rates, staged pre-operative endovascular embolization has facilitated microsurgical resection with lower blood loss. Endovascular embolization is more often utilized in conjunction with surgical resection, and often the portions of the AVM and feeders that are completely embolized with Onyx or glue may not be surgically resected since they have been "internally obliterated." We present a case where the AVM was preoperatively embolized with Onyx and subsequently partially surgically resected. Post-operative angiography showed complete obliteration or "cure" of the AVM with no filling of the nidus or early venous drainage. The patient presented 12 months later with seizures and imaging showed volume loss in the residual Onyx cast and recanalization of the AVM nidus. The patient subsequently underwent repeat resection with complete removal of the residual AVM and Onyx cast. To our knowledge this is the first published report of volume loss within the Onyx cast leading to recanalization of the AVM nidus. This suggests that extreme care should be taken with partial resection of the AVM nidus or with embolization for cure, as late recanalization may occur. © The Author(s) 2015.
Onyx resorbtion with AVM recanalization after complete AVM obliteration
Bain, Mark D; Rasmussen, Peter A
2015-01-01
Brain arteriovenous malformations (BAVM) are some of the most complex lesions treated by clinical neuroscientists. The recent publication of the ARUBA trial, showing higher complication rates with treatment compared with the natural history over a short period of follow-up, puts even more pressure on the physician to achieve complete BAVM eradication without complication. These lesions are often treated by multimodality therapy with some combination of endovascular embolization, radiosurgery, and microsurgical resection; however, multimodality therapy involves the additive risk of procedural complication with each procedure. While surgical resection has long been accepted as monotherapy with good cure rates, staged pre-operative endovascular embolization has facilitated microsurgical resection with lower blood loss. Endovascular embolization is more often utilized in conjunction with surgical resection, and often the portions of the AVM and feeders that are completely embolized with Onyx or glue may not be surgically resected since they have been “internally obliterated.” We present a case where the AVM was preoperatively embolized with Onyx and subsequently partially surgically resected. Post-operative angiography showed complete obliteration or “cure” of the AVM with no filling of the nidus or early venous drainage. The patient presented 12 months later with seizures and imaging showed volume loss in the residual Onyx cast and recanalization of the AVM nidus. The patient subsequently underwent repeat resection with complete removal of the residual AVM and Onyx cast. To our knowledge this is the first published report of volume loss within the Onyx cast leading to recanalization of the AVM nidus. This suggests that extreme care should be taken with partial resection of the AVM nidus or with embolization for cure, as late recanalization may occur. PMID:26015523
Serial casting for reconstruction of a deformed Charcot foot: a case report.
Rosenblum, Jonathan I; Weiss, Shmuel; Gazes, Michael; Amit-Kohn, Michal
2015-05-01
Charcot neuroarthropathy may occur in patients with peripheral neuropathy who do not notice pain while their bones and joints collapse or breakdown under the constant pressure of body weight. This can lead to ulcerations from severe deformity and potentially limb-threatening and life-threatening infections. Current treatments vary from immobilization to extensive reconstructive surgical interventions. Serial casting, used to correct many pediatric deformities while bones are often more pliable, was used with a 63-year-old male patient who presented with an active phase of Charcot foot with ulceration. The patient previously underwent foot reconstruction and had all hardware removed prior to serial casting. Due to the potential pliability of the bones, serial casting was attempted to reform the shape and position of the foot in a reverse Ponseti-type serial casting to create a more stable structure with less deformity that could lead to epithelial breakdown. The patient regained full ambulation with a plantargrade foot and no wounds, and was followed without complications for 36 months. Serial weekly casting was an effective modality for treatment of this patient's Charcot foot deformity.
A new conservative-dynamic treatment for the acute ruptured Achilles tendon.
Neumayer, Felix; Mouhsine, Elyazid; Arlettaz, Yvan; Gremion, Gérald; Wettstein, Michael; Crevoisier, Xavier
2010-03-01
There is a trend towards surgical treatment of acute ruptured Achilles tendon. While classical open surgical procedures have been shown to restore good functional capacity, they are potentially associated with significant complications like wound infection and paresthesia. Modern mini-invasive surgical techniques significantly reduce these complications and are also associated with good functional results so that they can be considered as the surgical treatment of choice. Nevertheless, there is still a need for conservative alternative and recent studies report good results with conservative treatment in rigid casts or braces. We report the use of a dynamic ankle brace in the conservative treatment of Achilles tendon rupture in a prospective non-randomised study of 57 consecutive patients. Patients were evaluated at an average follow-up time of 5 years using the modified Leppilahti Ankle Score, and the first 30 patients additionally underwent a clinical examination and muscular testing with a Cybex isokinetic dynamometer at 6 and 12 months. We found good and excellent results in most cases. We observed five complete re-ruptures, almost exclusively in case of poor patient's compliance, two partial re-ruptures and one deep venous thrombosis complicated by pulmonary embolism. Although prospective comparison with other modern treatment options is still required, the functional outcome after early ankle mobilisation in a dynamic cast is good enough to ethically propose this method as an alternative to surgical treatment.
Serious infectious complications related to extremity cast/splint placement in children.
Delasobera, B Elizabeth; Place, Rick; Howell, John; Davis, Jonathan E
2011-07-01
Extremity injuries necessitating splinting or casting are commonly seen in the emergency department (ED) setting. Subsequently, it is not uncommon for patients to present to the ED with complaints related to an extremity cast or splint. To present a literature-based approach to the identification and initial management of patients with possible infectious cast/splint complications in the ED setting. We present two cases of serious infectious complications arising from extremity cast/splint placement seen in a single pediatric ED: a case of toxic shock syndrome in an 8-year-old child, and a case of necrotizing fasciitis resulting in upper extremity amputation in a 3-year-old child. A wide spectrum of potential extremity cast/splint infectious complications may be seen, which include limb- or life-threatening infections such as toxic shock syndrome and necrotizing fasciitis. Simply considering these diagnoses, and removing the cast or splint to carefully inspect the affected extremity, are potential keys to early identification and optimal outcome of cast/splint complications. It is also prudent to maintain particular vigilance when treating a patient with a water-exposed cast, which may lead to moist padding, skin breakdown, and potential infection. In patients with suspected serious infections, aggressive fluid management and antibiotic therapy should be initiated and appropriate surgical consultation obtained without delay. Copyright © 2011 Elsevier Inc. All rights reserved.
Ryan, Justin R; Almefty, Kaith K; Nakaji, Peter; Frakes, David H
2016-04-01
Neurosurgery simulator development is growing as practitioners recognize the need for improved instructional and rehearsal platforms to improve procedural skills and patient care. In addition, changes in practice patterns have decreased the volume of specific cases, such as aneurysm clippings, which reduces the opportunity for operating room experience. The authors developed a hands-on, dimensionally accurate model for aneurysm clipping using patient-derived anatomic data and three-dimensional (3D) printing. Design of the model focused on reproducibility as well as adaptability to new patient geometry. A modular, reproducible, and patient-derived medical simulacrum was developed for medical learners to practice aneurysmal clipping procedures. Various forms of 3D printing were used to develop a geometrically accurate cranium and vascular tree featuring 9 patient-derived aneurysms. 3D printing in conjunction with elastomeric casting was leveraged to achieve a patient-derived brain model with tactile properties not yet available from commercial 3D printing technology. An educational pilot study was performed to gauge simulation efficacy. Through the novel manufacturing process, a patient-derived simulacrum was developed for neurovascular surgical simulation. A follow-up qualitative study suggests potential to enhance current educational programs; assessments support the efficacy of the simulacrum. The proposed aneurysm clipping simulator has the potential to improve learning experiences in surgical environment. 3D printing and elastomeric casting can produce patient-derived models for a dynamic learning environment that add value to surgical training and preparation. Copyright © 2016 Elsevier Inc. All rights reserved.
A Method for Immobilizing the Forelimbs of Rabbits.
Thunder, Richard M.; Chang, James; Broome, Rosemary L.; Most, Daniel
1998-09-01
Immobilizing the forelimbs of rabbits after surgical procedures is necessary to allow healing, yet it often can be difficult, because rabbits are often able to pull the repaired limb from its cast soon after surgery and well before adequate tissue repair has taken place. We describe here a method of immobilization that uses 3 layers of cast material combined with flexion of the radiocarpal and radiohumeral joints. This method resulted in successful immobilization in 97% of the rabbits on which it was used.
Healing of rotator cuff tendons using botulinum toxin A and immobilization in a rat model.
Gilotra, Mohit N; Shorofsky, Michael J; Stein, Jason A; Murthi, Anand M
2016-03-15
We evaluated effects of botulinum toxin A (Botox) and cast immobilization on tendon healing in a rat model. Injection of Botox into rat supraspinatus was hypothesized to reduce muscle active force and improved healing. Eighty-four supraspinatus tendons were surgically transected and repaired in 42 Sprague-Dawley rats (transosseous technique). After repair, supraspinatus muscle was injected with saline or Botox (3 or 6 U/kg). Half the shoulders were cast-immobilized for the entire postoperative period; half were allowed free cage activity. Histology was examined at 2, 4, 8, and 12 weeks. A healing zone cross-sectional area was measured, and biomechanical testing of repair strength and tendon viscoelastic properties was conducted at 4 and 12 weeks. Botox alone and cast immobilization alone exhibited increased ultimate load compared with controls (saline injection, no immobilization) at 4 weeks. No difference in ultimate load occurred between Botox-only and cast-only groups. At 12 weeks, the Botox (6 U/kg) plus cast immobilization group was significantly weakest (p < 0.05). A trend was shown toward decreased healing zone cross-sectional areas in casted groups. Supraspinatus Botox injection after rotator cuff repair might help protect the repair. However, cast immobilization plus Botox administration is harmful to rotator cuff healing in a rat tendon model.
Precision of Fit of Titanium and Cast Implant Frameworks Using a New Matching Formula
Sierraalta, Marianella; Vivas, Jose L.; Razzoog, Michael E.; Wang, Rui-Feng
2012-01-01
Statement of the Problem. Fit of prosthodontic frameworks is linked to the lifetime survival of dental implants and maintenance of surrounding bone. Purpose. The purpose of this study was to evaluate and compare the precision of fit of milled one-piece Titanium fixed complete denture frameworks to that of conventional cast frameworks. Material and Methods. Fifteen casts fabricated from a single edentulous CAD/CAM surgical guide were separated in two groups and resin patterns simulating the framework for a fixed complete denture developed. Five casts were sent to dental laboratories to invest, cast in a Palladium-Gold alloy and fit the framework. Ten casts had the resin pattern scanned for fabrication of milled bars in Titanium. Using measuring software, positions of implant replicas in the definitive model were recorded. The three dimensional spatial orientation of each implant replica was matched to the implant replica. Results. Results demonstrated the mean vertical gap of the Cast framework was 0.021 (+0.004) mm and 0.012 (0.002) mm determined by fixed and unfixed best-fit matching coordinate system. For Titanium frameworks they were 0.0037 (+0.0028) mm and 0.0024 (+0.0005) mm, respectively. Conclusions. Milled one-piece Titanium fixed complete denture frameworks provided a more accurate precision of fit then traditional cast frameworks. PMID:22550486
Hui, Catherine; Joughin, Elaine; Nettel-Aguirre, Alberto; Goldstein, Simon; Harder, James; Kiefer, Gerhard; Parsons, David; Brauer, Carmen; Howard, Jason
2014-01-01
Background The Ponseti method of congenital idiopathic clubfoot correction has traditionally specified plaster of Paris (POP) as the cast material of choice; however, there are negative aspects to using POP. We sought to determine the influence of cast material (POP v. semirigid fibreglass [SRF]) on clubfoot correction using the Ponseti method. Methods Patients were randomized to POP or SRF before undergoing the Ponseti method. The primary outcome measure was the number of casts required for clubfoot correction. Secondary outcome measures included the number of casts by severity, ease of cast removal, need for Achilles tenotomy, brace compliance, deformity relapse, need for repeat casting and need for ancillary surgical procedures. Results We enrolled 30 patients: 12 randomized to POP and 18 to SRF. There was no difference in the number of casts required for clubfoot correction between the groups (p = 0.13). According to parents, removal of POP was more difficult (p < 0.001), more time consuming (p < 0.001) and required more than 1 method (p < 0.001). At a final follow-up of 30.8 months, the mean times to deformity relapse requiring repeat casting, surgery or both were 18.7 and 16.4 months for the SRF and POP groups, respectively. Conclusion There was no significant difference in the number of casts required for correction of clubfoot between the 2 materials, but SRF resulted in a more favourable parental experience, which cannot be ignored as it may have a positive impact on psychological well-being despite the increased cost associated. PMID:25078929
Bae, Donald S; Lynch, Hayley; Jamieson, Katherine; Yu-Moe, C Winnie; Roussin, Christopher
2017-09-06
The purpose of this investigation was to characterize the clinical efficacy and cost-effectiveness of simulation training aimed at reducing cast-saw injuries. Third-year orthopaedic residents underwent simulation-based instruction on distal radial fracture reduction, casting, and cast removal using an oscillating saw. The analysis compared incidences of cast-saw injuries and associated costs before and after the implementation of the simulation curriculum. Actual and potential costs associated with cast-saw injuries included wound care, extra clinical visits, and potential total payment (indemnity and expense payments). Curriculum costs were calculated through time-derived, activity-based accounting methods. The researchers compared the costs of cast-saw injuries and the simulation curriculum to determine overall savings and return on investment. In the 2.5 years prior to simulation, cast-saw injuries occurred in approximately 4.3 per 100 casts cut by orthopaedic residents. For the 2.5-year period post-simulation, the injury rate decreased significantly to approximately 0.7 per 100 casts cut (p = 0.002). The total cost to implement the casting simulation was $2,465.31 per 6-month resident rotation. On the basis of historical data related to cast-saw burns (n = 6), total payments ranged from $2,995 to $25,000 per claim. The anticipated savings from averted cast-saw injuries and associated medicolegal payments in the 2.5 years post-simulation was $27,131, representing an 11-to-1 return on investment. Simulation-based training for orthopaedic surgical residents was effective in reducing cast-saw injuries and had a high theoretical return on investment. These results support further investment in simulation-based training as cost-effective means of improving patient safety and clinical outcomes. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Analysis and comparison of the biomechanical properties of univalved and bivalved cast models.
Crickard, Colin V; Riccio, Anthony I; Carney, Joseph R; Anderson, Terrence D
2011-01-01
Fiberglass casts are frequently valved to relieve the pressure associated with upper extremity swelling after a surgical procedure or when applied after reduction of a displaced fracture in a child. Although different opinions exist regarding the valving of casts, no research to date has explored the biomechanical effects of this commonly used technique. As cast integrity is essential for the maintenance of fracture reduction, it is important to understand whether casts are structurally compromised after valving. Understanding the effects of valving on cast integrity may help guide clinicians in the technique of valving while minimizing the potential for a loss of fracture reduction. Thirty standardized cylindrical fiberglass cast models were created. Ten models were left intact, 10 were univalved, and 10 were bivalved. All the models were mechanically tested by a 3-point bending apparatus secured to a biaxial materials testing system. Load to failure and bending stiffness were recorded for each sample. Differences in load of failure and bending stiffness were compared among the groups. Unvalved cast models had the highest failure load and bending stiffness, whereas bivalved casts showed the lowest value for both failure load and bending stiffness. Univalved casts had a failure load measured to be between those of unvalved and bivalved cast models. Analysis of variance showed significance when failure load and bending stiffness data among all the groups were compared. A post hoc Bonferroni statistical analysis showed significance in bending stiffness between intact and bivalved models (P < 0.01), intact and univalved models (P < 0.01), but no significant difference in bending stiffness between univalved and bivalved models (P > 0.01). Differences in measured failure load values were found to be statistically significant among all cast models (P < 0.01). Valving significantly decreases the bending stiffness and load to failure of fiberglass casts. Univalved casts have a higher load to failure than bivalved casts. Valving adversely alters the structural integrity of fiberglass casts. This may impair a cast's ability to effectively immobilize an extremity or maintain a fracture reduction.
Lin, Yen-Kun; Yau, Hong-Tzong; Wang, I-Chung; Zheng, Cheng; Chung, Kwok-Hung
2015-06-01
Stereoscopic visualization concept combined with head-mounted displays may increase the accuracy of computer-aided implant surgery. The aim of this study was to develop an augmented reality-based dental implant placement system and evaluate the accuracy of the virtually planned versus the actual prepared implant site created in vitro. Four fully edentulous mandibular and four partially edentulous maxillary duplicated casts were used. Six implants were planned in the mandibular and four in the maxillary casts. A total of 40 osteotomy sites were prepared in the casts using stereolithographic template integrated with augmented reality-based surgical simulation. During the surgery, the dentist could be guided accurately through a head-mounted display by superimposing the virtual auxiliary line and the drill stop. The deviation between planned and prepared positions of the implants was measured via postoperative computer tomography generated scan images. Mean and standard deviation of the discrepancy between planned and prepared sites at the entry point, apex, angle, depth, and lateral locations were 0.50 ± 0.33 mm, 0.96 ± 0.36 mm, 2.70 ± 1.55°, 0.33 ± 0.27 mm, and 0.86 ± 0.34 mm, respectively, for the fully edentulous mandible, and 0.46 ± 0.20 mm, 1.23 ± 0.42 mm, 3.33 ± 1.42°, 0.48 ± 0.37 mm, and 1.1 ± 0.39 mm, respectively, for the partially edentulous maxilla. There was a statistically significant difference in the apical deviation between maxilla and mandible in this surgical simulation (p < .05). Deviation of implant placement from planned position was significantly reduced by integrating surgical template and augmented reality technology. © 2013 Wiley Periodicals, Inc.
Radiation enteritis and radiation scoliosis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shah, M.; Eng, K.; Engler, G.L.
1980-09-01
Any patient with radiation scoliosis should be suspected of having a visceral lesion as well. Chronic radiation enteritis may be manifested by intestinal obstruction, fistulas, perforation, and hemorrhage. Intestinal obstruction is the most common complication, and must be differentiated from postoperative cast or from spinal-traction syndrome. Obstruction that does not respond promptly to conservative measures must be treated surgically. Irradiated bowel is ischemic, and necrosis with spontaneous perforation can only be avoided with early diagnosis and surgical intervention.
Onyx extravasation during embolization of a brain arteriovenous malformation.
Ikeda, Hiroyuki; Imamura, Hirotoshi; Agawa, Yuji; Imai, Yukihiro; Tani, Shoichi; Adachi, Hidemitsu; Ishikawa, Tatsuya; Mineharu, Yohei; Sakai, Nobuyuki
2017-04-01
During Onyx embolization to treat brain arteriovenous malformation (AVM), carefully observing the penetration of Onyx to the nidus is important in order to avoid complications such as hemorrhage, ischemia, and difficulty with microcatheter removal. We encountered a case of Onyx extravasation during embolization of a cerebellar AVM confirmed by surgical resection and pathological analysis. The patient was a 44-year-old man with Spetzler-Martin grade I cerebellar AVM who underwent Onyx embolization prior to resection of the brain AVM. While injecting Onyx into the nidus using the "plug-and-push" technique, Onyx extravasation was observed. Onyx injection was paused and subsequently restarted, thereby allowing continuation of embolization. An oblate Onyx cast that was entirely covered in cerebellar tissue was removed during total resection of the AVM, performed the same day. The surgically removed oblate Onyx cast did not contain brain tissue or vessel wall, and immunohistochemical staining against glial fibrillary acidic protein (GFAP) showed Onyx penetration into GFAP-positive cerebellar tissue. Onyx extravasation was confirmed based on intraoperative findings during resection as well as pathological findings. The patient has been followed for four years postoperatively, and adverse events caused by Onyx extravasation have not been observed. Unexpected cast of Onyx, remote from the vascular architecture of the AVM, may represent an intra-parenchymal extravasation.
Onyx extravasation during embolization of a brain arteriovenous malformation
Imamura, Hirotoshi; Agawa, Yuji; Imai, Yukihiro; Tani, Shoichi; Adachi, Hidemitsu; Ishikawa, Tatsuya; Mineharu, Yohei; Sakai, Nobuyuki
2016-01-01
During Onyx embolization to treat brain arteriovenous malformation (AVM), carefully observing the penetration of Onyx to the nidus is important in order to avoid complications such as hemorrhage, ischemia, and difficulty with microcatheter removal. We encountered a case of Onyx extravasation during embolization of a cerebellar AVM confirmed by surgical resection and pathological analysis. The patient was a 44-year-old man with Spetzler-Martin grade I cerebellar AVM who underwent Onyx embolization prior to resection of the brain AVM. While injecting Onyx into the nidus using the “plug-and-push” technique, Onyx extravasation was observed. Onyx injection was paused and subsequently restarted, thereby allowing continuation of embolization. An oblate Onyx cast that was entirely covered in cerebellar tissue was removed during total resection of the AVM, performed the same day. The surgically removed oblate Onyx cast did not contain brain tissue or vessel wall, and immunohistochemical staining against glial fibrillary acidic protein (GFAP) showed Onyx penetration into GFAP-positive cerebellar tissue. Onyx extravasation was confirmed based on intraoperative findings during resection as well as pathological findings. The patient has been followed for four years postoperatively, and adverse events caused by Onyx extravasation have not been observed. Unexpected cast of Onyx, remote from the vascular architecture of the AVM, may represent an intra-parenchymal extravasation. PMID:27903925
Resistant metatarsus adductus: prospective randomized trial of casting versus orthosis.
Herzenberg, John E; Burghardt, Rolf D
2014-03-01
Metatarsus adductus is a common pediatric foot deformity related to intrauterine molding. It is usually a mild deformity that responds well to simple observation or minimal treatment with a home program of stretching. Resistant cases may need a more aggressive approach such as serial casting or special bracing to avoid the need for surgical intervention. We compared clinical outcomes using serial casting with orthoses for resistant metatarsus adductus. We prospectively treated 27 infants (43 feet) between the ages 3 and 9 months who failed home stretching treatment. Patients were randomized to either serial plaster casting or Bebax orthoses. Footprints and simulated weight-bearing anteroposterior and lateral view radiographs were made at entry and follow-up. There was no statistical difference between casting and Bebax for the following parameters: age at study entry, length of treatment, number of clinic visits, follow-up, and follow-up maintenance treatments. Both groups showed improvement in footprint and radiographic measurements post-treatment, without worsening of heel valgus. The Bebax group had greater improvement in the footprint heel bisector measurement than the casting group. The Bebax treatment requires more active parental cooperation. A simulated cost analysis of materials and office visit charges, however, revealed that Bebax treatment was significantly less expensive, about half the cost of casting. Because of the cost savings and virtually identical clinical results, we recommend the Bebax orthosis for resistant metatarsus in pre-walking infants with parents who are compliant. Other considerations include specific insurance plans, which may pay for casts but not orthoses.
Surgical Management of Chyloptysis.
Gillaspie, Erin A; Lim, Kaiser; Nichols, Francis C
2018-02-01
Chyloptysis is a rare clinical presentation. Diagnosis is challenging and requires recognition of milky-sputum or bronchial casts. We describe a case of chyloptysis secondary to thoracic lymphangiectasia that necessitated surgical ligation of the main thoracic duct and accessory branches. The patient had no postoperative complications, and at 6-month follow-up remained symptom-free. A paucity of literature describes the management of chyloptysis. We review diagnosis, treatment considerations and operative principles. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Cervical osteotomy in ankylosing spondylitis: evaluation of new developments.
Langeloo, Danielle D; Journee, Henricus L; Pavlov, Paul W; de Kleuver, Marinus
2006-04-01
Cervical osteotomy can be performed on patients with cervical kyphosis due to ankylosing spondylitis. This study reviews the role of two new developments in cervical osteotomy surgery: internal fixation and transcranial electrical stimulated motor evoked potential monitoring (TES-MEP). From 1999 to 2004, 16 patients underwent a C7-osteotomy with internal fixation. In 11 patients, cervical osteotomy was performed in a sitting position with halo-cast immobilization (group S), five patients underwent surgery in prone position with Mayfield clamp fixation (group P). In group P, longer fusion towards T4-T6 could be obtained that created a more stable fixation. Therefore, post-operative immobilization protocol of group P was simplified from halo-cast to cervical orthosis. Consolidation was obtained in all patients without loss of correction. Post-operative chin-brow to vertical angle measured 5 degrees (range 0-15). TES-MEP was successfully performed during all surgical procedures. In total, nine neurological events were registered. Additional surgical intervention resulted in recovery of amplitudes in six of nine events. In two patients spontaneous recovery took place. One patient showed no recovery of amplitudes despite surgical intervention and a partial C6 spinal cord lesion occurred. We conclude that C7 osteotomy with internal fixation has been shown to be a reliable and stable technique. When surgery is performed the in prone position, distal fixation can be optimally obtained allowing post-operative treatment by cervical orthosis instead of a halo-cast. TES-MEP monitoring has been shown to be a reliable neuromonitoring technique with high clinical relevancy during cervical osteotomy because it allows timely intervention before occurrence of permanent cord damage in a large proportion of the patients.
Spines of Steel: A Case of Surgical Enthusiasm in Cold War America.
Linker, Beth
2016-01-01
Just as the prevalence of scoliosis began to decline precipitously after World War II, American orthopedic surgeon Dr. Paul R. Harrington devised a new, invasive surgical system whereby implantable prosthetic metal rods and hooks were used to straighten curved backs. By the 1970s, "Harrington rods" had become the gold standard of surgical scoliosis care in the United States, replacing more conventional methods of exercise, bracing, and casting. This article situates the success of Harrington rods within a much larger and historically longer debate about why, when compared to those in other nations, American surgeons appear to be "more aggressive" and "knife-happy." Using Harrington's papers and correspondence, I argue that patients played a vital role in the rise of spinal surgery. As such, this article examines not only how surgical enthusiasm has been historically measured, defined, and morally evaluated, but also how scoliosis became classified as a debility in need of surgical management.
Harris, Ian, A; Naylor, Justine, M; Buchbinder, Rachelle; Ivers, Rebecca; Balogh, Zsolt; Smith, Paul; Mittal, Rajat; Xuan, Wei; Howard, Kirsten; Vafa, Arezoo; Yates, Piers; Rieger, Bertram; Smith, Geoff; Elkinson, Ilia; Kim, Woosung; Chehade, Mellick; Sungaran, Jai; Latendresse, Kim; Wong, James; Viswanathan, Sameer; Richardson, Martin; Shrestha, Kush; Drobetz, Herwig; Tran, Phong; Loveridge, Jeremy; Page, Richard; Hau, Raphael; Bingham, Roger; Mulford, Jonathan; Incoll, Ian
2017-01-01
Fractures of the distal radius are common and occur in all age groups. The incidence is high in older populations due to osteoporosis and increased falls risk. Considerable practice variation exists in the management of distal radius fractures in older patients ranging from closed reduction with cast immobilisation to open reduction with plate fixation. Plating is currently the most common surgical treatment. While there is evidence showing no significant advantage for some forms of surgical fixation over conservative treatment, and no difference between different surgical techniques, there is a lack of evidence comparing two of the most common treatments used: closed reduction and casting versus plating. Surgical management involves significant costs and risks compared with conservative management. High-level evidence is required to address practice variation, justify costs and to provide the best clinical outcomes for patients. Methods and analysis This pragmatic, multicentre randomised comparative effectiveness trial aims to determine whether plating leads to better pain and function and is more cost-effective than closed reduction and casting of displaced distal radius fractures in adults aged 60 years and older. The trial will compare the two techniques but will also follow consenting patients who are unwilling to be randomised in a separate, observational cohort. Inclusion of non-randomised patients addresses selection bias, provides practice and outcome insights about standard care, and improves the generalisability of the results from the randomised trial. Ethics and dissemination CROSSFIRE(Combined Randomised and Observational Study of Surgery for Fractures In the distal Radius in the Elderly) was reviewed and approved by The Hunter New England HREC (HNEHREC Reference No: 16/02/17/3.04). The results of the trial will be published in a peer-reviewed journal and will be disseminated via various forms of media. Results will be incorporated in clinical recommendations and practice guidelines produced by professional bodies. Registration CROSSFIRE has been registered with the Australian and New Zealand Clinical Trials Registry (ANZCTR: ACTRN12616000969460). PMID:28645976
Harris, Ian A; Naylor, Justine M; Lawson, Andrew; Buchbinder, Rachelle; Ivers, Rebecca; Balogh, Zsolt; Smith, Paul; Mittal, Rajat; Xuan, Wei; Howard, Kirsten; Vafa, Arezoo; Yates, Piers; Rieger, Bertram; Smith, Geoff; Elkinson, Ilia; Kim, Woosung; Chehade, Mellick; Sungaran, Jai; Latendresse, Kim; Wong, James; Viswanathan, Sameer; Richardson, Martin; Shrestha, Kush; Drobetz, Herwig; Tran, Phong; Loveridge, Jeremy; Page, Richard; Hau, Raphael; Bingham, Roger; Mulford, Jonathan; Incoll, Ian
2017-06-23
Fractures of the distal radius are common and occur in all age groups. The incidence is high in older populations due to osteoporosis and increased falls risk. Considerable practice variation exists in the management of distal radius fractures in older patients ranging from closed reduction with cast immobilisation to open reduction with plate fixation. Plating is currently the most common surgical treatment. While there is evidence showing no significant advantage for some forms of surgical fixation over conservative treatment, and no difference between different surgical techniques, there is a lack of evidence comparing two of the most common treatments used: closed reduction and casting versus plating. Surgical management involves significant costs and risks compared with conservative management. High-level evidence is required to address practice variation, justify costs and to provide the best clinical outcomes for patients. This pragmatic, multicentre randomised comparative effectiveness trial aims to determine whether plating leads to better pain and function and is more cost-effective than closed reduction and casting of displaced distal radius fractures in adults aged 60 years and older. The trial will compare the two techniques but will also follow consenting patients who are unwilling to be randomised in a separate, observational cohort. Inclusion of non-randomised patients addresses selection bias, provides practice and outcome insights about standard care, and improves the generalisability of the results from the randomised trial. CROSSFIRE(Combined Randomised and Observational Study of Surgery for Fractures In the distal Radius in the Elderly) was reviewed and approved by The Hunter New England HREC (HNEHREC Reference No: 16/02/17/3.04). The results of the trial will be published in a peer-reviewed journal and will be disseminated via various forms of media. Results will be incorporated in clinical recommendations and practice guidelines produced by professional bodies. CROSSFIRE has been registered with the Australian and New Zealand Clinical Trials Registry (ANZCTR: ACTRN12616000969460). © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Coetzee, J F; Edwards, L N; Mosher, R A; Bello, N M; O'Connor, A M; Wang, B; Kukanich, B; Blasi, D A
2012-03-01
Castration in weaned calves is stressful and affects profitability by reducing ADG and increasing susceptibility to disease. This study evaluated the effect of meloxicam, a nonsteroidal anti-inflammatory drug (NSAID), on performance and health of calves received as steers compared with bull calves surgically castrated on arrival at the feedlot. British × Continental bulls (n = 145) and steers (n = 113; BW = 193 to 285 kg) were transported for 12 h in 3 truckloads (d 0), weighed, and randomly assigned to receive either lactose placebo (CONT; 1 mg/kg) or meloxicam (MEL; 1 mg/kg) suspended in water and administered per os, 24 h before castration. On d 1, bulls were surgically castrated (CAST) and steers were processed without castration (STR). Combinations of CONT/MEL and CAST/STR were allocated to 24 pens (6 pens per treatment) of 8 to 14 calves each. Pen was the experimental unit. Plasma meloxicam concentrations at the time of castration (d 1) were determined by HPLC-mass spectroscopy. Pen-level ADG, DMI, and G:F were estimated using BW obtained on d 0, 14, and 28 and weigh-back of feed. Individual animals were classified as sick based on a depression score of ≥2 on a 5-point scale and a rectal temperature of ≥39.8°C. On d 0, 1, and 14, calf chute temperament was evaluated using a 4-point scale. Data were analyzed using generalized linear mixed models and survival curve analyses. Castration reduced pen ADG (P < 0.001) and G:F (P < 0.001) from d 1 to 14, yet no effects (P > 0.45) were apparent by d 28. For all treatment groups, DMI increased with days on feed (P < 0.0001) but was less in CAST compared with STR calves (P < 0.016) throughout the study. From d 15 to 28, ADG increased (P = 0.0011) in CAST but not STR calves, and G:F decreased (P = 0.0004) in STR but not CAST calves. In CAST calves only, MEL treatment reduced the pen-level first pull rate (P = 0.04) and reduced bovine respiratory disease morbidity rate (P = 0.03). The frequency of chute escape behavior was greater on arrival and at castration in CAST vs. STR calves (P < 0.01) but not significantly different at d 14 (P = 0.22). Mean MEL concentrations at castration were no different between treated STR and CAST calves (P = 0.70). Meloxicam administration before castration in postweaning calves reduced the incidence of respiratory disease at the feedlot. These findings have implications for developing NSAID protocols for use in calves at castration with respect to addressing animal health and welfare concerns.
Rereduction for Redisplacement of Both-Bone Forearm Shaft Fractures in Children.
Eismann, Emily A; Parikh, Shital N; Jain, Viral V
2016-06-01
There is a high rate of redisplacement after closed reduction and cast treatment of displaced both-bone forearm shaft fractures in children. Little evidence is available on the efficacy of rereduction of these redisplaced fractures. This study evaluates the impact of rereduction on radiographic outcomes and compares the cost to surgical stabilization. This retrospective study included 31 children (mean age, 6.3 y; 18 boys) treated with rereduction for redisplacement of a displaced both-bone forearm shaft fracture between 2008 and 2013. Angulation was measured on anteroposterior and lateral radiographs of the radius and ulna at injury, after reduction, at redisplacement, after rereduction, and at fracture union. Average procedure costs for rereduction and surgical stabilization were calculated. Initial reduction decreased apex volar angulation (initially >20 degrees) of both bones to a median of ≤2 degrees. After an average of 15 days (range, 4 to 35 d), apex volar angulation of the radius worsened to 9 degrees, and apex ulnar angulation worsened to >10 degrees for both bones. For every 5 days after initial reduction, apex ulnar angulation of the radius worsened by 4 degrees. Rereduction reduced apex ulnar and volar angulation of both bones to <5 degrees, which was maintained after cast removal. There were no complications. The average procedure cost for rereduction was $2056 compared with $4589 for surgical stabilization with or without implant removal. Rereduction of both-bone forearm shaft fractures after redisplacement following initial closed reduction had satisfactory radiographic outcomes and is a safe, effective, and less expensive option than surgical stabilization. Level IV-therapeutic.
Treating the Proximal Interphalangeal Joint in Swan Neck and Boutonniere Deformities.
Fox, Paige M; Chang, James
2018-05-01
Swan neck and boutonniere deformities of the proximal interphalangeal (PIP) joint are challenging to treat. In a swan neck deformity, the PIP joint is hyperextended with flexion at the distal interphalangeal (DIP) joint. In a boutonniere deformity, there is flexion the PIP joint with hyperextension of the DIP joint. When the deformities are flexible, treatment begins with splinting. However, when the deformity is fixed, serial casting or surgery is often necessary to restore joint motion before surgical correction. Many surgical techniques have been described to treat both conditions. Unfortunately, incomplete correction and deformity recurrence are common. Published by Elsevier Inc.
Watanabe, Jun; Maruya, Jun; Nishimaki, Keiichi; Ito, Yasushi
2016-01-01
Most dural arteriovenous fistula (DAVF) in superior sagittal sinus (SSS) requires multimodal treatment. Onyx embolization is useful for DAVF; however, scalp artery embolization has cast extrusion risk. A 59-year-old male presented with involuntary movements of both legs and progressive dementia. Cerebral angiography demonstrated the DAVF in the SSS fed by bilateral superficial temporal, occipital, and middle meningeal arteries. The posterior SSS was thrombosed, and the main drainers were cortical veins. Combined treatment with transarterial embolization using Onyx and transvenous embolization using coils was performed. Although symptoms were improved, a small DAVF remained. Two months later, Onyx cast extrusion through the scalp was observed, requiring removal and debridement because of infection at the extrusion sites. Surgery for the residual DAVF would be difficult because of scalp condition; therefore, an additional endovascular treatment was conducted, completely occluding DAVF. Onyx embolization is useful for DAVF; however, scalp artery embolization has cast extrusion risk. Therefore, scalp infection should be considered because it may preclude additional surgical procedures.
de Negreiros, Wagner Araujo; Verde, Marcus Aurelio Rabelo Lima; da Silva, Antonio Materson; Pinto, Lecio Pitombeira
2012-04-01
This clinical report shows the use of extraoral implants to rehabilitate an ocular defect, focusing the surgical and prosthetic procedures. Using local anesthesia and a surgical template obtained from the diagnostic wax ocular pattern, two cylinder dental implants were strategically placed in the lateral aspect of the right infraorbital region. Four months later, an acrylic framework including two spherical magnets was made using plastic UCLA abutments. After casting laboratory steps, a customized silicon prosthetic appliance was fabricated from the diagnostic wax ocular pattern and attached to the Co-Cr framework, observing its profile and seating aspects. The patient was satisfied with the treatment result, due to the retention, esthetics, and adhesive-free method to anchor his ocular prostheses. © 2012 by the American College of Prosthodontists.
Arunyanak, Sirikarn P; Harris, Bryan T; Grant, Gerald T; Morton, Dean; Lin, Wei-Shao
2016-07-01
This report describes a digital approach for computer-guided surgery and immediate provisionalization in a partially edentulous patient. With diagnostic data obtained from cone-beam computed tomography and intraoral digital diagnostic scans, a digital pathway of virtual diagnostic waxing, a virtual prosthetically driven surgical plan, a computer-aided design and computer-aided manufacturing (CAD/CAM) surgical template, and implant-supported screw-retained interim restorations were realized with various open-architecture CAD/CAM systems. The optional CAD/CAM diagnostic casts with planned implant placement were also additively manufactured to facilitate preoperative inspection of the surgical template and customization of the CAD/CAM-fabricated interim restorations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
[Operative vs. non-operative treatment of acute Achilles tendon rupture].
Bulatović, Nikola; Aligrudić, Velisa; Dasić, Zarko; Pepić, Dzihad; Jusković, Aleksandar
2013-01-01
It affects most frequently middle aged recreational male sportsmen (30-50 years old), previously followed by prodromal symptoms (5-33%). Rupture spot is 3 to 5 cm above heel bone vertex (90-95%) Retrospective study. WORKING OBJECTIVE: Comparison of functional re-. suits and complications of cast immobilization non-operative treatment and open suture surgical treatment. Overall 46 patients included who were treated at the Clinic for Orthopedics and Traumatology within the Clinical Center of Montenegro in Podgorica between 2004 and 2012. Patients were divided into two groups: I group consisted of 21 patients (45.65%) who were treated by cast immobilization and the II (control) group consisted of 25 patients (54.35%) who were treated by open surgical technique. Division by gender: 44 male patients (95.65%) and 2 female patients (4.35%). WORKING RESULTS: The average age of patients was 38.8 +/- 2.79 (21-60 years of age); for the patients treated operationally 37.1 +/- 3.98 years of age, for the patients treated non-operationally 40.2 +/- 2.39; 28 right side patients (60.86%), 18 left side patients (39.14%); Surface infection detected on 1 patient (2.17%); 2 patients with partial rupture, while 3 patients had complete rupture during early rehabilitation period after immobilization was taken off. Complete rupture detected on 3 patients (6.25%) has been recovered surgically. Thromboembolism noticed on 3 patients (6.52%) while 2 patients (4.34%) were affected by pulmonary embolism. Tendon elongation present on 3 patients (Magnetic Resonance (MR) Diagnostics) and on 1 patient reoperation was performed 3 months after the primary surgical intervention. This study didn't show significant statistical difference between two ways of treatment, but early immobilization is recommended because of better results. In case of Achilles tendon rupture, the advantage should be given to the surgical treatment, especially if younger population is treated.
21 CFR 888.3540 - Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis.
Code of Federal Regulations, 2013 CFR
2013-04-01
...: Articulating Surfaces Made of Metal, Ceramic and Plastic Materials,” and (viii) ISO 9001:1994 “Quality Systems... of Porous Metal Coatings,” (v) F 1108-97 “Titanium-6 Aluminum-4 Vanadium Alloy Castings for Surgical Implants,” (vi) F 1147-95 “Test Method for Tension Testing of Porous Metal Coatings,” (vii) F 1537-94...
21 CFR 888.3540 - Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis.
Code of Federal Regulations, 2014 CFR
2014-04-01
...: Articulating Surfaces Made of Metal, Ceramic and Plastic Materials,” and (viii) ISO 9001:1994 “Quality Systems... of Porous Metal Coatings,” (v) F 1108-97 “Titanium-6 Aluminum-4 Vanadium Alloy Castings for Surgical Implants,” (vi) F 1147-95 “Test Method for Tension Testing of Porous Metal Coatings,” (vii) F 1537-94...
21 CFR 888.3540 - Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis.
Code of Federal Regulations, 2012 CFR
2012-04-01
...: Articulating Surfaces Made of Metal, Ceramic and Plastic Materials,” and (viii) ISO 9001:1994 “Quality Systems... of Porous Metal Coatings,” (v) F 1108-97 “Titanium-6 Aluminum-4 Vanadium Alloy Castings for Surgical Implants,” (vi) F 1147-95 “Test Method for Tension Testing of Porous Metal Coatings,” (vii) F 1537-94...
A simple customized surgical guide for orthodontic miniplates with tube.
Paek, Janghyun; Su, Ming-Jeaun; Kwon, Soon-Yong; Kim, Seong-Hun; Chung, Kyu-Rhim; Nelson, Gerald
2012-09-01
This article reports the use of a customized surgical guide for simple and precise C-tube plate placement with minimized incision. Patients who were planning to have orthodontic miniplate treatment because of narrow interradicular space were recruited for this study. A combined silicone and stainless steel wire surgical guide for the C-tube was fabricated on the cast model. The taller wire of the positioning guide is used to accurately start the incision. The incision guide-wire position is verified by placing the miniplate on the coronal horizontal wire to confirm that the incision will coordinate with the screw holes. Because the miniplate is firmly held in place, there is no risk of the miniplate anchoring screws (diameter, 1.5 mm; length, 4 mm) sliding on the bone surface during placement with a manual hand driver. The surgical guide was placed on the clinical site, and it allowed precise placement of the miniplate with minimum incision and preventing from slippage or path-of-insertion angulation errors that might interfere with accurate placement. Customized surgical guide enables precise planning for miniplate positions in anatomically complex sites.
Heterofunctional nanosheet controlling cell adhesion properties by collagen coating.
Niwa, Daisuke; Fujie, Toshinori; Lang, Thorsten; Goda, Nobuhito; Takeoka, Shinji
2012-08-01
Recently, biomaterials have been widely used in a variety of medical applications. We previously reported that a poly-l-lactic acid (PLLA) nanosheet shows anti-adhesive properties and constitutes a useful biomaterial for preventing unwanted wound adhesion in surgical operations. In this article, we examine whether the PLLA nanosheet can be specifically modified with biomacromolecules on one surface only. Such an approach would endow each side of the nanosheet with discrete functions, that is anti-adhesive and pro-healing properties. We fabricated two distinct PLLA nanosheets: (i) collagen cast on the surface of a PLLA nanosheet (Col-Cast-PLLA) and (ii) collagen spin-coated on the nanosheet (Col-Spin-PLLA). In the Col-Spin-PLLA nanosheet, the collagen layer had a thickness of 5-10 nm on the PLLA surface and displayed increased hydrophilicity compared to both PLLA and Col-Cast-PLLA nanosheets. In addition, atomic force microscopy showed disorganized collagen fibril formation on the PLLA layer when covered using the spin-coating method, while apparent bundle formations of collagen were formed in the Col-Cast-PLLA nanosheet. The Col-Spin-PLLA nanosheet provided a microenvironment for cells to adhere and spread. By contrast, the Col-Cast-PLLA nanosheet displayed reduced cell adhesion compared to the Col-Spin-PLLA nanosheet. Consistent with these findings, immunocytochemical analysis clearly showed fine networks of actin filaments in cells cultured on the Col-Spin-PLLA, but not the Col-Cast-PLLA nanosheet. Therefore, the Col-Spin-PLLA nanosheet was shown to be more suitable for acting as a scaffold. In conclusion, we have succeeded in developing a heterofunctional nanosheet comprising a collagen modified side, which has the ability to rapidly adhere cells, and an unmodified side, which acts as an adhesion barrier, by using a spin-coating technique.
Watanabe, Jun; Maruya, Jun; Nishimaki, Keiichi; Ito, Yasushi
2016-01-01
Background: Most dural arteriovenous fistula (DAVF) in superior sagittal sinus (SSS) requires multimodal treatment. Onyx embolization is useful for DAVF; however, scalp artery embolization has cast extrusion risk. Case Description: A 59-year-old male presented with involuntary movements of both legs and progressive dementia. Cerebral angiography demonstrated the DAVF in the SSS fed by bilateral superficial temporal, occipital, and middle meningeal arteries. The posterior SSS was thrombosed, and the main drainers were cortical veins. Combined treatment with transarterial embolization using Onyx and transvenous embolization using coils was performed. Although symptoms were improved, a small DAVF remained. Two months later, Onyx cast extrusion through the scalp was observed, requiring removal and debridement because of infection at the extrusion sites. Surgery for the residual DAVF would be difficult because of scalp condition; therefore, an additional endovascular treatment was conducted, completely occluding DAVF. Conclusion: Onyx embolization is useful for DAVF; however, scalp artery embolization has cast extrusion risk. Therefore, scalp infection should be considered because it may preclude additional surgical procedures. PMID:27313969
Mobius Syndrome: A 35-Year Single Institution Experience.
K McClure, Philip; Kilinc, Eray; Oishi, Scott; I Riccio, Anthony; A Karol, Lori
Mobius syndrome is a rare syndrome that is known to be associated with a variety of orthopaedic conditions including scoliosis, clubfoot, transverse limb deficiencies, Poland syndrome, and a myriad of hand conditions. To date, no large series exist to characterize the orthopaedic manifestations of Mobius syndrome. Medical records at a single tertiary pediatric institution were reviewed for all patients diagnosed with Mobius syndrome from January 1, 1980 to December 31, 2015. Records and radiographs were reviewed for associated orthopaedic conditions and their management. In total, 44 patients with Mobius syndrome were identified. Age at presentation ranged from 6 days to 14 years. When compared with the general population, patients with Mobius syndrome had an increased incidence of clubfoot (41%), Poland syndrome (20%), and scoliosis (14%). Clubfoot treated both before and after the institution of Ponseti casting had a high rate of requiring posteromedial release, with a significant rate of subsequent revision. Hip dysplasia was noted in 1 patient and required surgical correction. Other associated syndromes included arthrogryposis, Pierre Robin syndrome, and chromosome 10 defect. Mobius syndrome is accompanied by an increased rate of several orthopaedic problems; most notably clubfoot, scoliosis, and upper extremity differences that often require surgical treatment. The management of clubfoot in the setting of Mobius syndrome often requires surgical intervention due to failure of casting, and seems to have a higher rate of need for revision. Early involvement of orthopaedists in the care of patients with Mobius syndrome is often necessary. Orthopaedist should counsel families that treatment may be more complex than that of idiopathic disease. Level IV-case series.
[Legg-Calvé-Perthes disease (LCPD). Principles of diagnosis and treatment].
Manig, M
2013-10-01
The clinical course of Legg-Calvé-Perthes disease (LCPD) is variable. Diagnosis, nonsurgical and surgical methods of treatment have evolved over many decades, from abduction casts and braces to advanced surgical containment methods which are now the mainstay of treatment. This article presents a general view and a critical evaluation of the literature. The main prognostic factors are patient age at the onset of LCPD, the range of motion and the extent of the necrotic process according to the classification of Herring and Catterall. The main aims of surgical and nonsurgical treatment of LCPD are to prevent prearthrotic deformity of the femoral head, relief of symptoms, containment of the femoral head and restoration of congruence of the hip joint. Each patient needs to be evaluated individually. Every child must receive an adapted treatment and continued follow-up at regular intervals.
Selvaraj, Sunantha; Dorairaj, Jayachandran; Mohan, Jayashree; Simon, Paul
2016-01-01
Introduction: An accurate and passive fit of implant framework prosthesis, as well as the successful surgical operation is suggested as one of the critical requirements for long-term implant success. Objective: The purpose of this in vitro study was to evaluate the accuracy of the master cast using open tray impression technique with conventional and novel splinting materials. Methodology: A mandibular reference model with four ADIN implants was done. Ten custom trays were fabricated using the light curable resin sheets. Medium body polyether impression material was used. These trays were randomly divided between the two groups, with five trays in each group. Impression techniques were divided into two groups namely: Group A: Direct impression technique with open tray impression copings splinted with autopolymerizing acrylic resin (GC pattern resin). Group B: Direct impression technique with open tray impression copings splinted with Pro-temp TM 4 (bis-GMA) syringable temporization material. Thus, final impressions were made. Total of 10 master casts were fabricated. Evaluation of casts using Dynascope-Vision Engineering, TESA microhite two- dimension and coordinate measuring machine were used. Results: Statistical comparisons were made using ANOVA test and post-hoc test. Same amount of deviation values obtained with resin splinted and bis-GMA splinted impression copings. Conclusion: The master cast obtained by both the splinting material exhibits no difference from the reference model. So bis-GMA can be used, which is easy to handle, less time consuming, less technique sensitive, rigid, and readily available material in clinics. PMID:27141167
Hribernik, Marija; Trotovšek, Blaž
2014-04-01
The aim of this study is to present the anatomical data about intrahepatic venous anastomoses found in normal human livers. The focus is on the middle hepatic vein (MHV) anastomoses, because their existence or non-existence could be of crucial importance in tumour resections as well as in split or living donor liver transplantations. The frequency of livers with intrahepatic venous anastomoses was determined on 164 corrosion casts and the diameter of each anastomosis was measured. Additionally, the type of connection and the position within the liver (liver segment) was determined for each MHV anastomosis. Intrahepatic venous anastomoses were found in 46 % (75/164), whereas MHV anastomoses were found in 28 % (44/164) of liver casts. Most commonly (39/44), MHV had anastomotic connections with the right hepatic vein (RHV), and also with the inferior RHV, the left hepatic vein and the short subhepatic vein. In more than three quarters of liver casts, MHV-RHV anastomoses were found in liver segment 8; in 45 % of cases, there was more than one anastomosis in this liver segment. The diameter of MHV-RHV anastomoses found in segment 8 was ≥1 mm in 90.6 % of cases. As MHV anastomoses were present in more than a quarter of all examined liver casts, we believe that detailed anatomical data presented in this article, together with up to date radiologic technics which enable even 3D reconstruction of venous anastomoses in the liver, could contribute to the clinician's decisions when planning surgical procedures.
Willett, Keith; Keene, David J; Mistry, Dipesh; Nam, Julian; Tutton, Elizabeth; Handley, Robert; Morgan, Lesley; Roberts, Emma; Briggs, Andrew; Lall, Ranjit; Chesser, Timothy J S; Pallister, Ian; Lamb, Sarah E
2016-10-11
Ankle fractures cause substantial morbidity in older persons. Surgical fixation is the contemporary intervention but is associated with infection and other healing complications. To determine whether initial fracture treatment with close contact casting, a molded below-knee cast with minimal padding, offers outcome equivalent to that with immediate surgery, with fewer complications and less health resource use. This was a pragmatic, equivalence, randomized clinical trial with blinded outcome assessors. A pilot study commenced in May 2004, followed by multicenter recruitment from July 2010 to November 2013; follow-up was completed May 2014. Recruitment was from 24 UK major trauma centers and general hospitals. Participants were 620 adults older than 60 years with acute, overtly unstable ankle fracture. Exclusions were serious limb or concomitant disease or substantial cognitive impairment. Participants were randomly assigned to surgery (n = 309) or casting (n = 311). Casts were applied in the operating room under general or spinal anesthesia by a trained surgeon. The primary 6-month, per-protocol outcome was the Olerud-Molander Ankle Score at 6 months (OMAS; range, 0-100; higher scores indicate better outcomes and fewer symptoms), equivalence prespecified as ±6 points. Secondary outcomes were quality of life, pain, ankle motion, mobility, complications, health resource use, and patient satisfaction. Among 620 adults (mean age, 71 years; 460 [74%] women) who were randomized, 593 (96%) completed the study. Nearly all participants (579/620; 93%) received allocated treatment; 52 of 275 (19%) who initially received casting later converted to surgery, which was allowable in the casting treatment pathway to manage early loss of fracture reduction. At 6 months, casting resulted in ankle function equivalent to that with surgery (OMAS score, 66.0 [95% CI, 63.6-68.5] for surgery vs 64.5 [95% CI, 61.8-67.2] for casting; mean difference, -0.6 [95% CI, -3.9 to 2.6]; P for equivalence = .001). Infection and wound breakdown were more common with surgery (29/298 [10%] vs 4/275 [1%]; odds ratio [OR], 7.3 [95% CI, 2.6-20.2]), as were additional operating room procedures (18/298 [6%] for surgery and 3/275 [1%] for casting; OR, 5.8 [95% CI, 1.8-18.7]). Radiologic malunion was more common in the casting group (38/249 [15%] vs 8/274 [3%] for surgery; OR, 6.0 [95% CI, 2.8-12.9]). Casting required less operating room time compared with surgery (mean difference [minutes/participant], -54 [95% CI, -58 to -50]). There were no significant differences in other secondary outcomes: quality of life, pain, ankle motion, mobility, and patient satisfaction. Among older adults with unstable ankle fracture, the use of close contact casting compared with surgery resulted in similar functional outcomes at 6 months. Close contact casting may be an appropriate treatment for such patients. isrctn.com Identifier: ISRCTN04180738.
Management and Case Outcome of Gastric Impaction in Four Raptors: A Case Series.
Applegate, Jeffrey R; Van Wettere, Arnaud; Christiansen, Emily F; Degernes, Laurel A
2017-03-01
Four captive raptors, an American kestrel ( Falco sparverius ), peregrine falcon ( Falco peregrinus ), golden eagle ( Aquila chrysaetos ), and barn owl ( Tyto alba ), were diagnosed with ventricular and/or proventricular foreign material impactions consisting of artificial turf substrate, paper and plastic substrate, grass, and newspaper. Partial or total anorexia was reported in all birds and decreased casting in 2 birds. Survey radiographs confirmed presence of gastric enlargement in all 4 birds. The kestrel and eagle were treated unsuccessfully with gastroscopy and gastric lavage, respectively, followed by surgical intervention to remove the ventricular impactions. Both birds died of undetermined causes after surgery. The peregrine falcon died before medical or surgical intervention was started, and the owl was managed successfully with oral mineral oil and liquid diet to facilitate egestion of the foreign material as a pellet. Lead poisoning was suspected as the predisposing cause for foreign body ingestion in the eagle, but underlying causes for pica in the other birds were not determined. Radiographs can provide useful diagnostic information in sick raptors that exhibit vomiting or changes in appetite or casting frequency, and may help guide treatment decisions of impacted birds. Careful consideration of substrate, enrichment items, and access to potential foreign material that could be ingested may be the best pre-emptive management strategy in captive raptors.
A novel workflow for computer guided implant surgery matching digital dental casts and CBCT scan
DE VICO, G.; FERRARIS, F.; ARCURI, L.; GUZZO, F.; SPINELLI, D.
2016-01-01
SUMMARY Nowadays computer-guided “flap-less” surgery for implant placement using stereolithographic tem-plates is gaining popularity among clinicians and patients. The advantages of this surgical protocol are its minimally invasive nature, accuracy of implant placement, predictability, less post-surgical discomfort and reduced time required for definitive rehabilitation. Aim of this work is to describe a new protocol (Smart Fusion by Nobel Biocare), thanks to which is now possible to do a mini-invasive static guided implant surgery, in partially edentulous patients with at least 6 remaining teeth, without the use of a radiographic guide. This is possible thanks to a procedure named surface mapping based on the matching between numerous points on the surface of patient’s dental casts and the corresponding anatomical surface points in the CBCT data. The full protocol is examined focusing the attention on the clinical and laboratory procedures. Conclusions Also with some critical points and needing an adequate learning curve, this protocol allows to select the ideal implant position in depth, inclination and mesio-distal distance between natural teeth and or other implants enabling a very safe and predictable rehabilitation compared with conventional surgery. It represents a good tool for the best compromise between anatomy, function and aesthetic, able to guarantee better results in all clinical situations. PMID:28042429
Sardari Nia, Peyman; Heuts, Samuel; Daemen, Jean; Luyten, Peter; Vainer, Jindrich; Hoorntje, Jan; Cheriex, Emile; Maessen, Jos
2017-02-01
Mitral valve repair performed by an experienced surgeon is superior to mitral valve replacement for degenerative mitral valve disease; however, many surgeons are still deterred from adapting this procedure because of a steep learning curve. Simulation-based training and planning could improve the surgical performance and reduce the learning curve. The aim of this study was to develop a patient-specific simulation for mitral valve repair and provide a proof of concept of personalized medicine in a patient prospectively planned for mitral valve surgery. A 65-year old male with severe symptomatic mitral valve regurgitation was referred to our mitral valve heart team. On the basis of three-dimensional (3D) transoesophageal echocardiography and computed tomography, 3D reconstructions of the patient's anatomy were constructed. By navigating through these reconstructions, the repair options and surgical access were chosen (minimally invasive repair). Using rapid prototyping and negative mould fabrication, we developed a process to cast a patient-specific mitral valve silicone replica for preoperative repair in a high-fidelity simulator. Mitral valve and negative mould were printed in systole to capture the pathology when the valve closes. A patient-specific mitral valve silicone replica was casted and mounted in the simulator. All repair techniques could be performed in the simulator to choose the best repair strategy. As the valve was printed in systole, no special testing other than adjusting the coaptation area was required. Subsequently, the patient was operated, mitral valve pathology was validated and repair was successfully done as in the simulation. The patient-specific simulation and planning could be applied for surgical training, starting the (minimally invasive) mitral valve repair programme, planning of complex cases and the evaluation of new interventional techniques. The personalized medicine could be a possible pathway towards enhancing reproducibility, patient's safety and effectiveness of a complex surgical procedure. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
van Niekerk, Michael; Jawad, Farrah; Huntley, James S; McCowan, Stuart
2011-05-01
Compartment syndrome complicating a ruptured Achilles tendon has previously been reported in a surgically treated patient. However--to our knowledge--this is the first report of compartment syndrome following conservative treatment. A 45-year-old man ruptured his Achilles tendon and elected to have treatment in an equinus cast. Three weeks later, he developed compartment syndrome and despite fasciotomy, required surgical debridement of his anterior compartment. Delay in both diagnosis and subsequent fasciotomy resulted in a poor outcome. Any suspicion of compartment syndrome mandates early compartmental pressure monitoring. The exact aetiology is uncertain but we speculate that the equinus position of his ankle combined with weight-bearing, was a major contributing factor.
In vivo characterization of the integration and vascularization of a silk-derived surgical scaffold.
Kijanska, Monika; Marmaras, Anastasios; Hegglin, Alicia; Kurtcuoglu, Vartan; Giovanoli, Pietro; Lindenblatt, Nicole
2016-08-01
The application of acellular matrices, biomaterials, and polymeric scaffolds in reconstructive surgery facilitates postsurgical tissue remodeling and is increasingly used clinically in order to improve tissue healing and implant coverage. This study presents an in vivo investigation of the integration of the knitted, silk-derived surgical scaffold, SERI(®) with regard to angiogenesis and wound healing. SERI(®) Surgical Scaffold was implanted into a full-thickness skin defect in male C57BL/6J mice (n = 45) via the dorsal skinfold chamber (DSC). Skin tissue samples were collected for histology on days 2, 5, 7, 10, 14, and 21 (n = 5 per time point) post implantation. Immunohistochemistry was performed for various angiogenic and inflammatory markers, as well as collagen deposition (CD31, VEGF, CD3, CD45, Desmin, and Sirius red). Vascular corrosion casting was used to assess the neovasculature within the silk and was visualized with scanning electron microscopy. We observed both early and late stages of inflammation during the healing process characterized by the infiltration of regenerating tissue by different subsets of leukocytes. Histological analysis displayed capillary-containing granulation tissue with full scaffold integration. In addition, collagen deposition within the scaffold and full skin defect was significantly increased over time. Qualitative analysis of the regenerated vasculature through corrosion casting and scanning electron microscopy revealed a complex, angiogenic network of capillaries originating from the wound bed. Based on these findings, SERI(®) displays the potential to be a promising resorbable bioengineered material for use in reconstructive surgery. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Ackermann, O; Heigel, U; Lazic, D; Vogel, T; Schofer, M D; Rülander, C
2012-04-01
For the clinical planning of mass events the emergency departments are of critical importance, but there are still no data available for the workload in these cases. As this is essential for an effective medical preparation, we calculated the workload based on the ICD codes of the vicitims at the Loveparade 2010 in Duisburg. Based on the patient data of the Loveparade 2010 we used a filter diagnosis to estimate the number of shock room patients, regular admittances, surgical wound treatments, applications of casts or splints, and diagnosis of drug abuse. In addition every patient was classified to a Manchester Triage System category. This resulted in a chronological and quantitative work-load profile of the emergency department, which was evaluated by the clinical experiences of the departmental medical staff. The workload profile as a whole displayed a realistic image of the real true situation on July 24, 2010. While only the number, diagnosis and chronology of medical surgical patients was realistic, the MTS classification was not. The emergency department had a maximum of 6 emergency room admittances, 6 regular admittances, 4-5 surgical wound treatments, 3 casts and 2 drug abuse patients per hour. The calculation of workload from the ICD data is a reasonable tool for retrospective estimation of the workload of an emergency department, the data can be used for future planning. The retrospective MTS grouping is at present not suitable for a realistic calculation. Retrospective measures in the MTS groups are at present not sufficiently suitable for valid data publication. © Georg Thieme Verlag KG Stuttgart · New York.
A step-by-step development of real-size chest model for simulation of thoracoscopic surgery.
Morikawa, Toshiaki; Yamashita, Makoto; Odaka, Makoto; Tsukamoto, Yo; Shibasaki, Takamasa; Mori, Shohei; Asano, Hisatoshi; Akiba, Tadashi
2017-08-01
For the purpose of simulating thoracoscopic surgery, we have conducted stepwise development of a life-like chest model including thorax and intrathoracic organs. First, CT data of the human chest were obtained. First-generation model: based on the CT data, each component of the chest was made from a 3D printer. A hard resin was used for the bony thorax and a rubber-like resin for the vessels and bronchi. Lung parenchyma, muscles and skin were not created. Second-generation model: in addition to the 3D printer, a cast moulding method was used. Each part was casted using a 3D printed master and then assembled. The vasculature and bronchi were casted using silicon resin. The lung parenchyma and mediastinum organs were casted using urethane foam. Chest wall and bony thorax were also casted using a silicon resin. Third-generation model: foamed polyvinyl alcohol (PVA) was newly developed and casted onto the lung parenchyma. The vasculature and bronchi were developed using a soft resin. A PVA plate was made as the mediastinum, and all were combined. The first-generation model showed real distribution of the vasculature and bronchi; it enabled an understanding of the anatomy within the lung. The second-generation model is a total chest dry model, which enabled observation of the total anatomy of the organs and thorax. The third-generation model is a wet organ model. It allowed for realistic simulation of surgical procedures, such as cutting, suturing, stapling and energy device use. This single-use model achieved realistic simulation of thoracoscopic surgery. As the generation advances, the model provides a more realistic simulation of thoracoscopic surgery. Further improvement of the model is needed. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Anatomical variations of the right hepatic veins and their relevance to surgery.
Hribernik, Marija; de Cecchis, Lucio; Trotovsek, Blaz; Gadzijev, Eldar M; Ravnik, Dean
2003-01-01
In a morphological study of the right hepatic veins anatomical characteristics of surgical importance were looked for. 110 cadaveric human livers were prepared by the corrosion casts method. The confluence patterns of the superior right hepatic vein, the hepatocaval confluence, the accessory right hepatic veins and the anastomoses between hepatic veins in the right hemiliver were examined. Four types of the superior right hepatic vein, based on the length of its trunk and the confluence pattern of its main tributaries were determined and their frequency was calculated. Type I was found in 20%, type II in 40%, type III in 25% and type IV in 15%. Accessory right hepatic veins with a minimal caliber of 0.4 cm, which were always present in type IV, were also found in other types, all together in 27% of the casts. The tributary-free part of the superior right hepatic vein at hepatocaval confluence was longer than 1 cm in 77%. In the right hemiliver 109 anastomoses were found in 29/110 liver casts. Knowing the characteristics of different superior right hepatic vein types and of the accessory right hepatic veins may be useful in segment-oriented liver resections and in right side living donor resections.
Three-Dimensional Printing in Orthopedic Surgery.
Eltorai, Adam E M; Nguyen, Eric; Daniels, Alan H
2015-11-01
Three-dimensional (3D) printing is emerging as a clinically promising technology for rapid prototyping of surgically implantable products. With this commercially available technology, computed tomography or magnetic resonance images can be used to create graspable objects from 3D reconstructed images. Models can enhance patients' understanding of their pathology and surgeon preoperative planning. Customized implants and casts can be made to match an individual's anatomy. This review outlines 3D printing, its current applications in orthopedics, and promising future directions. Copyright 2015, SLACK Incorporated.
Robicsek, Francis; Watts, Larry T
2010-11-01
Pectus carinatum or keel chest is a spectrum of progressive inborn anomalies of the anterior chest wall, named after the keel (carina) of ancient Roman ships. It defines a wide spectrum of inborn protrusion anomalies of the sternum and/or the adjacent costal cartilages. Pectus carinatum is often associated with various conditions, notably Marfan disease, homocystinuria, prune belly, Morquio syndrome, osteogenesis imperfecta, Noonan syndrome, and mitral valve prolapse. Treatment of pectus carinatum by nonsurgical methods such as exercise and casting has not been worthwhile, whereas surgical management is simple and successful.
RapidSplint: virtual splint generation for orthognathic surgery - results of a pilot series.
Adolphs, Nicolai; Liu, Weichen; Keeve, Erwin; Hoffmeister, Bodo
2014-01-01
Within the domain of craniomaxillofacial surgery, orthognathic surgery is a special field dedicated to the correction of dentofacial anomalies resulting from skeletal malocclusion. Generally, in such cases, an interdisciplinary orthodontic and surgical treatment approach is required. After initial orthodontic alignment of the dental arches, skeletal discrepancies of the jaws can be corrected by distinct surgical strategies and procedures in order to achieve correct occlusal relations, as well as facial balance and harmony within individualized treatment concepts. To transfer the preoperative surgical planning and reposition the mobilized dental arches with optimal occlusal relations, surgical splints are typically used. For this purpose, different strategies have been described which use one or more splints. Traditionally, these splints are manufactured by a dental technician based on patient-specific dental casts; however, computer-assisted technologies have gained increasing importance with respect to preoperative planning and its subsequent surgical transfer. In a pilot study of 10 patients undergoing orthognathic corrections by a one-splint strategy, two final occlusal splints were produced for each patient and compared with respect to their clinical usability. One splint was manufactured in the traditional way by a dental technician according to the preoperative surgical planning. After performing a CBCT scan of the patient's dental casts, a second splint was designed virtually by an engineer and surgeon working together, according to the desired final occlusion. For this purpose, RapidSplint, a custom-made software platform, was used. After post-processing and conversion of the datasets into .stl files, the splints were fabricated by the PolyJet procedure using photo polymerization. During surgery, both splints were inserted after mobilization of the dental arches then compared with respect to their clinical usability according to the occlusal fitting. Using the workflow described above, virtual splints could be designed and manufactured for all patients in this pilot study. Eight of 10 virtual splints could be used clinically to achieve and maintain final occlusion after orthognathic surgery. In two cases virtual splints were not usable due to insufficient occlusal fitting, and even two of the traditional splints were not clinically usable. In five patients where both types of splints were available, their occlusal fitting was assessed as being equivalent, and in one case the virtual splint showed even better occlusal fitting than the traditional splint. In one case where no traditional splint was available, the virtual splint proved to be helpful in achieving the final occlusion. In this pilot study it was demonstrated that clinically usable splints for orthognathic surgery can be produced by computer-assisted technology. Virtual splint design was realized by RapidSplint®, an in-house software platform which might contribute in future to shorten preoperative workflows for the production of orthognathic surgical splints.
Ultrasound-guided minimally invasive surgery for achilles tendon rupture: preliminary results.
Wang, Chen-Chie; Chen, Pei-Yu; Wang, Ting-Ming; Wang, Chung-Li
2012-07-01
Many surgeons prefer surgical repair for Achilles tendon ruptures in an attempt to reduce the risk of rerupture. To minimize wound complications, the use of minimally invasive surgery has become more popular recently. In line with this, the use of ultrasound to guide Achilles tendon repair is reported in this study. From March 2005 to January 2008, 23 patients with Achilles tendon rupture were repaired by the same surgeon. The ages of the patients ranged from 19 to 67 years old, with an average of 43 years old. The repair of the Achilles tendon was achieved through a stab wound under the guidance of ultrasonography. A control group consisted of 25 patients who received traditional open Achilles tendon repair. The average operation time was 52 minutes, and the average wound size was 1.1 cm. The short leg cast was removed 4 weeks after the surgery, and serial casting was used for another 3 to 4 weeks. The postoperative AOFAS ankle-hindfoot scores were 98.7 in the experimental group, 96.5 in the control group with no significant difference. The rates of local infection, stiffness of the ankle, pain of the scar and sural nerve injury were better in the experimental group than in the control group with significant difference. Ultrasound-guided surgery was a good choice due to its availability and real-time soft tissue visualization. It can further minimize the size of the surgical wound. Our method has the potential to achieve reliable results.
2016-01-01
Background: The aim of this study is to determine the best surgical/orthodontic treatment plan for the complete bilateral and unilateral cleft lip and palate patient to achieve all treatment goals of facial aesthetics, speech, dental function, and psychosocial development. Methods: Review of 40 years of serial complete bilateral cleft lip and palate and complete unilateral cleft lip and palate dental casts and photographs from birth to adolescence, with serial cephs starting at 4 years. This was part of a multicenter international 3-dimensional palatal growth study of serial dental casts of patients who developed good speech, occlusion, and facial growth. Results: Nasoalveolar molding and gingivoperiosteoplasty were introduced without proven longitudinal benefits. The procedure bodily retruded the premaxilla, which “telescoped” backward causing synostosis at the premaxillary vomerine suture. The resulting midfacial recessiveness with an anterior dental crossbite can only be corrected by midfacial protraction or a Le Fort I surgery. Conclusions: Staged orthodontic/surgical treatment limiting premaxillary retraction forces to lip adhesion or forces that cause only premaxillary ventroflexion produce the best results. The palatal cleft should be closed between 18 and 24 months when the ratio of the cleft to the palatal size medial to the alveolar ridge is at least 10%. The protruding premaxilla should only be ventroflexed but never bodily retruded. The facial growth pattern and degree of palatal bone deficiency are the main items to be considered in treatment planning. PMID:27579230
Cassetta, M; Giansanti, M
2016-07-01
A reduction in orthodontic treatment time can be attained using corticotomies. The aggressive nature of corticotomy due to the elevation of muco-periosteal flaps and to the duration of the surgery raised reluctance for its employ among patients and dental community. This study aims to provide detailed information on the design and manufacture of a 3D-printed CAD-CAM (computer-aided design and computer-aided manufacturing) surgical guide which can aid the clinician in achieving a minimally-invasive, flapless corticotomy. An impression of dental arches was created; the models were digitally-acquired using a 3D scanner and saved as STereoLithography ( STL ) files. The patient underwent cone beam computed tomography (CBCT): images of jaws and teeth were transformed into 3D models and saved as an STL file. An acrylic template with the design of a surgical guide was manufactured and scanned. The STLs of jaws, scanned casts, and acrylic templates were matched. 3D modeling software allowed the view of the 3D models from different perspectives and planes with perfect rendering. The 3D model of the acrylic template was transformed into a surgical guide with slots designed to guide, at first, a scalpel blade and then a piezoelectric cutting insert. The 3D STL model of the surgical guide was printed. This procedure allowed the manufacturing of a 3D-printed CAD/CAM surgical guide, which overcomes the disadvantages of the corticotomy, removing the need for flap elevation. No discomfort, early surgical complications or unexpected events were observed. The effectiveness of this minimally-invasive surgical technique can offer the clinician a valid alternative to other methods currently in use.
[Early onset scoliosis. What are the options?].
Farrington, D M; Tatay-Díaz, A
2013-01-01
The prognosis of children with progressive early onset scoliosis has improved considerably due to recent advances in surgical and non-surgical techniques and the understanding of the importance of preserving the thoracic space. Improvements in existing techniques and development of new methods have considerably improved the management of this condition. Derotational casting can be considered in children with documented progression of a <60° curve without previous surgical treatment. Both single and dual growing rods are effective, but the latter seem to offer better results. Hybrid constructs may be a better option in children who require a low-profile proximal anchor. The vertical expandable prosthetic titanium rib (VEPTR(®)) appears to be beneficial for patients with congenital scoliosis and fused ribs, and thoracic Insufficiency Syndrome. Children with medical comorbidities who may not tolerate repeated lengthenings should be considered for Shilla or Luque Trolley technique. Growth modulation using shape memory alloy staples or other tethers seem promising for mild curves, although more research is required to define their precise indications. Copyright © 2013 SECOT. Published by Elsevier Espana. All rights reserved.
Cho, Jin-Hyung; Park, Wonse; Park, Kyeong-Mee; Kim, Seo-Yul
2017-01-01
Digital dentistry has influenced many dental procedures, such as three-dimensional (3D) diagnosis and treatment planning, surgical splints, and prosthetic treatments. Patient-specific protective appliances (PSPAs) prevent dental injury during endotracheal intubation. However, the required laboratory work takes time, and there is the possibility of tooth extraction while obtaining the dental impression. In this technical report, we utilized new digital technology for creating PSPAs, using direct intraoral scanners and 3D printers for dental cast fabrication. PMID:28879329
Cho, Jin-Hyung; Park, Wonse; Park, Kyeong-Mee; Kim, Seo-Yul; Kim, Kee-Deog
2017-03-01
Digital dentistry has influenced many dental procedures, such as three-dimensional (3D) diagnosis and treatment planning, surgical splints, and prosthetic treatments. Patient-specific protective appliances (PSPAs) prevent dental injury during endotracheal intubation. However, the required laboratory work takes time, and there is the possibility of tooth extraction while obtaining the dental impression. In this technical report, we utilized new digital technology for creating PSPAs, using direct intraoral scanners and 3D printers for dental cast fabrication.
Tatematsu, Tsutomu; Suzuki, Ayumi; Oda, Risa; Sakane, Tadashi; Kawano, Osamu; Haneda, Hiroshi; Moriyama, Satoru; Sasaki, Hidefumi; Nakanishi, Ryoichi
2017-01-01
Background A gatekeeper T790M mutation is thought to cause resistance to epidermal growth factor receptor tyrosine kinase inhibitor (EGFR-TKI) treatment. The detection of a 2nd mutation is important for planning the next therapy when patients acquire resistance to the first line EGFR-TKI. Methods We used a competitive allele-specific polymerase chain reaction (CAST-PCR) to analyze the incidence and clinical significance of T790M mutations in 153 lung adenocarcinomas with EGFR-activating mutations. To increase the sensitivity and specificity of the detection of T790M mutations, we subjected 20 of the 153 cases to a digital PCR. The genomic DNAs were extracted from frozen, surgically resected tumor tissue specimens. Results The CAST-PCR detected T790M mutations in 45 (29.4%) of the 153 cases. The analytical sensitivity in the detection T790M mutations was 0.13–2.65% (average 0.27%, median 0.20%). In contrast, the digital PCR, detected T790M mutations in 8 (40%) out of 20 cases. Conclusions Our study shows that the pretreatment incidence of T790M mutation was less than that reported in previous studies. In order to clinically use pretreatment EGFR T790M mutation identification method, we should clarify the adequate methods and tissue preserved status. PMID:28932544
Matthews, Paul A; Scammell, Brigitte E; Ali, Arfan; Coughlin, Timothy; Nightingale, Jessica; Khan, Tanvir; Ollivere, Ben J
2018-05-31
Following surgical fixation of ankle fractures, the traditional management has included immobilisation for 6 weeks in a below-knee cast. However, this can lead to disuse atrophy of the affected leg and joint stiffness. While early rehabilitation from 2 weeks post surgery is viewed as safe, controversy remains regarding its benefits. We will compare the effectiveness of early motion and directed exercise (EMADE) ankle rehabilitation, against usual care, i.e. 6 weeks' immobilisation in a below-knee cast. We have designed a pragmatic randomised controlled trial (p-RCT) to compare the EMADE intervention against usual care. We will recruit 144 independently living adult participants, absent of tissue-healing comorbidities, who have undergone surgical stabilisation of isolated Weber B ankle fractures. The EMADE intervention consists of a non-weight-bearing progressive home exercise programme, complemented with manual therapy and education. Usual care consists of immobilisation in a non-weight-bearing below-knee cast. The intervention period is between week 2 and week 6 post surgery. The primary outcome is the Olerud and Molander Ankle Score (OMAS) patient-reported outcome measure (PROM) at 12 weeks post surgery. Secondary PROMs include the EQ-5D-5 L questionnaire, return to work and return to driving, with objective outcomes including ankle range of motion. Analysis will be on an intention-to-treat basis. An economic evaluation will be included. The EMADE intervention is a package of care designed to address the detrimental effects of disuse atrophy and joint stiffness. An advantage of the OMAS is the potential of meta-analysis with other designs. Within the economic evaluation, the cost-utility analysis, may be used by commissioners, while the use of patient-relevant outcomes, such as return to work and driving, will ensure that the study remains pertinent to patients and their families. As it is being conducted in the clinical environment, this p-RCT has high external validity. Accordingly, if significant clinical benefits and cost-effectiveness are demonstrated, EMADE should become a worthwhile treatment option. A larger-scale, multicentre trial may be required to influence national guidelines. ISRCTN, ID: ISRCTN11212729 . Registered retrospectively on 20 March 2017.
Core Concepts: Orthopedic Intern Curriculum Boot Camp.
Seeley, Mark A; Kazarian, Erick; King, Brandon; Biermann, Janet S; Carpenter, James E; Caird, Michelle S; Irwin, Todd A
2016-01-01
Orthopedic surgical interns must gain a broad array of clinical skills in a short time. However, recent changes in health care have limited resident-patient exposures. With the reported success of simulation training in the surgical literature, the American Board of Orthopaedic Surgery (ABOS) and Residency Review Committee for Orthopaedic Surgery have required that surgical simulation training be a component of the intern curricula in orthopedic surgical residencies. This study examined the short-term effectiveness of an orthopedic "intern boot camp" covering 7 of 17 simulation training concept modules published by the ABOS. Eight orthopedic post-graduate year 1 (PGY-1) residents (study group) completed a structured 3-month curriculum and were compared with 7 post-graduate year 2 (PGY-2) residents (comparison group) who had just completed their orthopedic surgical internship. Seven core skills were assessed using both task-specific and global rating scales. The PGY-1 residents demonstrated a statistically significant improvement in all 7 modules with respect to their task-specific pre-test scores: sterile technique (P=.001), wound closure (P<.001), knot tying (P=.017), casting and splinting (P<.001), arthrocentesis (P=.01), basics of internal fixation (P<.001), and compartment syndrome evaluation (P=.004). After the camp, PGY-1 and -2 scores in task-specific measures were not significantly different. A 3-month simulation-based boot camp instituted early in orthopedic internship elevated a variety of clinical skills to levels exhibited by PGY-2 residents. Copyright 2016, SLACK Incorporated.
Fuchigami, T; Kimura, N; Kibe, T; Tezuka, M; Amir, M S; Suga, H; Takemoto, Y; Hashiguchi, M; Maeda-Iino, A; Nakamura, N
2017-11-01
To investigate the effects of pre-surgical nasoalveolar moulding (PNAM) on the maxillary arch and nasal form in patients with unilateral cleft lip and palate (UCLP). This is a retrospective case series study. The subjects were infants with complete UCLP who were treated with PNAM (n = 18) at Kagoshima University Medical and Dental Hospital (Japan) between 2006 and 2013. Maxillary dental casts and facial photographs were taken at the time of the first visit and immediately prior to lip surgery to evaluate the maxillary arch and nasal form changes. The dental casts were scanned with a laser scanner, and changes in the 3-Dimensional coordinates of anatomical landmarks and alveolar cleft width were analysed. Moreover, we investigated the correlation between the changes in the maxillary alveolar arch and nasal form. Regarding the maxillary alveolar arch form, the anterior points of the major segment had moved significantly to the cleft side just prior to the time of lip repair, and the alveolar cleft width was significantly decreased. For nasal form, the inclination and displacement of the columella were significantly improved. The improvement of columella inclination was moderately correlated with the posterior movement of the anterior points of the major segment. These findings indicate that PNAM for infants with UCLP enhanced symmetry in the maxillary alveolar arch and nasolabial form. In addition, the posterior movement of the anterior points of the maxillary alveolar arch was correlated with the improvement of columella deformation. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Reichert, Paulo R.; Renz, John F.; D’Albuquerque, Luiz A. C.; Rosenthal, Philip; Lim, Robert C.; Roberts, John P.; Ascher, Nancy L.; Emond, Jean C.
2000-01-01
Objective To evaluate intrahepatic vascular and biliary anatomy of the left lateral segment (LLS) as applied to living-donor and split-liver transplantation. Summary Background Data Living-donor and split-liver transplantation are innovative surgical techniques that have expanded the donor pool. Fundamental to the application of these techniques is an understanding of intrahepatic vascular and biliary anatomy. Methods Pathologic data obtained from cadaveric liver corrosion casts and liver dissections were clinically correlated with the anatomical findings obtained during split-liver, living-donor, and reduced-liver transplants. Results The anatomical relation of the left bile duct system with respect to the left portal venous system was constant, with the left bile duct superior to the extrahepatic transverse portion of the left portal vein. Four specific patterns of left biliary anatomy and three patterns of left hepatic venous drainage were identified and described. Conclusions Although highly variable, the biliary and hepatic venous anatomy of the LLS can be broadly categorized into distinct patterns. The identification of the LLS duct origin lateral to the umbilical fissure in segment 4 in 50% of cast specimens is significant in the performance of split-liver and living-donor transplantation, because dissection of the graft pedicle at the level of the round ligament will result in separate ducts from segments 2 and 3 in most patients, with the further possibility of an anterior segment 4 duct. A connective tissue bile duct plate, which can be clinically identified, is described to guide dissection of the segment 2 and 3 biliary radicles. PMID:11066137
Ramírez, Norman; Flynn, John M; Fernández, Samuel; Seda, Wallace; Macchiavelli, Raul E
2011-09-01
Idiopathic talipes equinovarus is the most common congenital defect characterized by the presence of a congenital dysplasia of all musculoskeletal tissues distal to the knee. For many years, the treatment has been based on extensive surgery after manipulation and cast trial. Owing to poor surgical results, Ponseti developed a new treatment protocol consisting of manipulation with cast and an Achilles tenotomy. The new technique requires 4 years of orthotic management to guarantee good results. The most recent studies have emphasized how difficult it is to comply with the orthotic posttreatment protocol. Poor compliance has been attributed to parent's low educational and low income level. The purpose of the study is to evaluate if poor compliance is due to the complexity of the orthotic use or if it is related to family education, cultural, or income factors. Fifty-three patients with 73 idiopathic talipes equinovarus feet were treated with the Ponseti technique and followed for 48 months after completing the cast treatment. There was a male predominance (72%). The mean age at presentation was 1 month (range: 1 wk to 7 mo). Twenty patients (38%) had bilateral involvement, 17 patients (32%) had right side affected, and 16 patients (30%) had the left side involved. The mean time of manipulation and casting treatment was 6 weeks (range: 4 to 10 wk). Thirty-eight patients (72%) required Achilles tenotomy as stipulated by the protocol. Recurrence was considered if there was a deterioration of the Dimeglio severity score requiring remanipulation and casting. Twenty-four out of 73 feet treated by our service showed the evidence of recurrence (33%). Sex, age at presentation, cast treatment duration, unilateral or bilateral, severity score, the necessity of Achilles tenotomy, family educational, or income level did not reveal any significant correlation with the recurrence risk. Noncompliance with the orthotic use showed a significant correlation with the recurrence rate. The noncompliance rate did not show any correlation with the patient demographic data or parent's education level, insurance, or cultural factors as proposed previously. The use of the brace is extremely relevant with the Ponseti technique outcome (recurrence) in the treatment of idiopathic talipes equinovarus. Noncompliance is not related to family education, cultural, or income level. The Ponseti postcasting orthotic protocol needs to be reevaluated to a less demanding option to improve outcome and brace compliance.
Accelerated treatment protocols: full arch treatment with interim and definitive prostheses.
Drago, Carl
2012-01-01
With the advent of titanium, root form implants and osseointegration, dental treatment has undergone a metamorphosis in recent years. These new techniques enable dentists to provide anchorage for various kinds of prostheses that improve masticatory function, esthetics, and comfort for patients. Implant treatment protocols have been improved relative to implant macro- and micro-geometries, surgical and prosthetic components, and treatment times. Over the past 20 years, immediate occlusal function (also known as loading) has been established as a predictable treatment modality, provided certain specific criteria are met. In many cases, edentulous patients, crippled by the loss of their teeth, can undergo outpatient surgical and prosthetic procedures and return to a masticatory function that is near normal--sometimes after only one day of surgical and prosthetic treatment. This treatment option is also available for patients with advanced, generalized periodontal disease. Computer-assisted design/Computer-assisted manufacturing (CAD/CAM) has transformed how dental prostheses are made, offering improved accuracy, longevity, and biocompatibility; along with reduced labor costs and fewer complications than casting technologies. This article reviews the principles associated with immediate occlusal loading and illustrates one specific accelerated prosthodontic treatment protocol used to treat edentulous and partially edentulous patients with interim and definitive prostheses.
Peixoto, Adriano Porto; Pinto, Ary dos Santos; Garib, Daniela Gamba; Gonçalves, João Roberto
2014-01-01
Introduction This study assessed the three-dimensional changes in the dental arch of patients submitted to orthodontic-surgical treatment for correction of Class II malocclusions at three different periods. Methods Landmarks previously identified on upper and lower dental casts were digitized on a three-dimensional digitizer MicroScribe-3DX and stored in Excel worksheets in order to assess the width, length and depth of patient's dental arches. Results During orthodontic preparation, the maxillary and mandibular transverse dimensions measured at the premolar regions were increased and maintained throughout the follow-up period. Intercanine width was increased only in the upper arch during orthodontic preparation. Maxillary arch length was reduced during orthodontic finalization, only. Upper and lower arch depths were stable in the study periods. Differences between centroid and gingival changes suggested that upper and lower arch premolars buccaly proclined during the pre-surgical period. Conclusions Maxillary and mandibular dental arches presented transverse expansion at premolar regions during preoperative orthodontic preparation, with a tendency towards buccal tipping. The transverse dimensions were not altered after surgery. No sagittal or vertical changes were observed during the follow-up periods. PMID:25279524
Peixoto, Adriano Porto; dos Santos Pinto, Ary; Garib, Daniela Gamba; Gonçalves, João Roberto
2014-01-01
This study assessed the three-dimensional changes in the dental arch of patients submitted to orthodontic-surgical treatment for correction of Class II malocclusions at three different periods. Landmarks previously identified on upper and lower dental casts were digitized on a three-dimensional digitizer MicroScribe-3DX and stored in Excel worksheets in order to assess the width, length and depth of patient's dental arches. During orthodontic preparation, the maxillary and mandibular transverse dimensions measured at the premolar regions were increased and maintained throughout the follow-up period. Intercanine width was increased only in the upper arch during orthodontic preparation. Maxillary arch length was reduced during orthodontic finalization, only. Upper and lower arch depths were stable in the study periods. Differences between changes in centroid and gingival points suggested that upper and lower premolars buccaly proclined during the pre-surgical period. Maxillary and mandibular dental arches presented transverse expansion at premolar regions during preoperative orthodontic preparation, with a tendency towards buccal tipping. The transverse dimensions were not altered after surgery. No sagittal or vertical changes were observed during the follow-up periods.
Topical anaesthesia reduces sensitivity of castration wounds in neonatal piglets
Windsor, Peter A.
2017-01-01
The aim of this study was to do determine the efficacy of the topical anaesthetic Tri-Solfen® in the amelioration of the pain of castration in piglets. The trial was conducted over a three day period, and blocked across six litters with 12 piglets treated on days one and two, and 16 on day three. The piglets were randomly allocated by weight and litter to 1 of 4 treatment groups: (i) sham castration (SHAM; n = 10); (ii) surgical castration with no anaesthetic intervention (CAST; n = 10); (iii) surgical castration with post-operative topical anaesthesia (TRI; n = 10); (iv) surgical castration with a pre-operative intra-testicular lignocaine hydrochloride injection (LIG; n = 10). Wound sensitivity testing involved von Frey monofilaments of weights 4g and 300g, and an 18 gauge needle, used to stimulate the wound and surrounding skin respectively, at various pre-determined sites. Neonatal piglets receiving topical anaesthesia (Tri-Solfen®) spray into castration wounds had significantly lower wound sensitivity responses for up to 4h, compared to those castrated following intra-testicular lignocaine injection or those with no treatment. The use of topical anaesthetic is suggested as a practical and affordable method of improving piglet welfare during castration. PMID:29140997
Occupational therapy and Colles' fractures.
Christensen, O M; Kunov, A; Hansen, F F; Christiansen, T C; Krasheninnikoff, M
2001-01-01
In this randomized trial, we enrolled 30 patients treated for a distal radius Colles' type fracture. The fractures were reduced if necessary and fixed in a below-elbow plaster cast for 5 weeks. One group consisting of 14 patients received instructions for shoulder; elbow and finger exercise and the other group consisting of 16 patients had occupational therapy. At 5 weeks, 3 and 9 months we measured the functional scores. There were no statistically significant differences between the groups at any time. It seems that for non-surgically treated patients with a distal radius fracture only instructions are necessary.
Intramedullary nailing: evolutions of femoral intramedullary nailing: first to fourth generations.
Russell, Thomas A
2011-12-01
Intramedullary femoral nailing is the gold standard for femoral shaft fixation but only in the past 27 years. This rapid replacement of closed traction and cast techniques in North America was a controversial and contentious evolution in surgery. As we enter the fourth generation of implant design, capabilities, and surgical technique, it is important to understand the driving forces for this technology. These forces included changes in radiographic imaging capabilities, biomaterial design and computer-assisted manufacturing, and the recognition of the importance of mobilization of the trauma patient to avoid systemic complications and optimize functional recovery.
Willett, Keith; Keene, David J; Morgan, Lesley; Gray, Bridget; Handley, Robert; Chesser, Tim; Pallister, Ian; Tutton, Elizabeth; Knox, Christopher; Lall, Ranjit; Briggs, Andrew; Lamb, Sarah E
2014-03-12
Ankle fractures account for 9% of all fractures with a quarter of these occurring in adults over 60 years. The short term disability and long-term consequences of this injury can be considerable. Current opinion favours open reduction and internal fixation (ORIF) over non-operative treatment (fracture manipulation and the application of a standard moulded cast) for older people. Both techniques are associated with complications but the limited published research indicates higher complication rates of fracture malunion (poor position at healing) with casting. The aim of this study is to compare ORIF with a modification of existing casting techniques, Close Contact Casting (CCC). We propose that CCC may offer an equivalent functional outcome to ORIF and avoid the risks associated with surgery. This study is a pragmatic multi-centre equivalence randomised controlled trial. 620 participants will be randomised to receive ORIF or CCC after sustaining an isolated displaced unstable ankle fracture. Participants will be recruited from a minimum of 20 National Health Service (NHS) acute hospitals throughout England and Wales. Participants will be aged over 60 years and be ambulatory prior to injury. Follow-up will be at six weeks and six months after randomisation. The primary outcome is the Olerud & Molander Ankle Score, a functional patient reported outcome measure, at 6 months. Follow-up will also include assessments of mobility, ankle range of movement, health related quality of life and complications. The six-month follow-up will be conducted face-to-face by an assessor blinded to the allocated intervention. A parallel economic evaluation will consider both a health service and a broader societal perspective including the individual and their family. In order to explore patient experience of their treatment and recovery, a purposive sample of 40 patients will also be interviewed using a semi-structured interview schedule between 6-10 weeks post treatment. This multicentre study was open to recruitment July 2010 and recruitment is due to be completed in December 2013. Current Controlled Trials ISRCTN04180738.
Miyazawa, Ken; Kawaguchi, Misuzu; Tabuchi, Masako; Goto, Shigemi
2010-12-01
Miniscrew implants have proven to be effective in providing absolute orthodontic anchorage. However, as self-drilling miniscrew implants have become more popular, a problem has emerged, i.e. root contact, which can lead to perforation and other root injuries. To avoid possible root damage, a surgical guide was fabricated and cone-beam computed tomography (CBCT) was used to incorporate guide tubes drilled in accordance with the planned direction of the implants. Eighteen patients (5 males and 13 females; mean age 23.8 years; minimum 10.7, maximum 45.5) were included in the study. Forty-four self-drilling miniscrew implants (diameter 1.6, and length 8 mm) were placed in interradicular bone using a surgical guide procedure, the majority in the maxillary molar area. To determine the success rates, statistical analysis was undertaken using Fisher's exact probability test. CBCT images of post-surgical self-drilling miniscrew implant placement showed no root contact (0/44). However, based on CBCT evaluation, it was necessary to change the location or angle of 52.3 per cent (23/44) of the guide tubes prior to surgery in order to obtain optimal placement. If orthodontic force could be applied to the screw until completion of orthodontic treatment, screw anchorage was recorded as successful. The total success rate of all miniscrews was 90.9 per cent (40/44). Orthodontic self-drilling miniscrew implants must be inserted carefully, particularly in the case of blind placement, since even guide tubes made on casts frequently require repositioning to avoid the roots of the teeth. The use of surgical guides, fabricated using CBCT images, appears to be a promising technique for placement of orthodontic self-drilling miniscrew implants adjacent to the dental roots and maxillary sinuses.
[Acute injuries of lateral ankle joint ligaments].
Lacko, M; Sidor, Z; Stolfa, S; Cellár, R; Vasko, G
2010-08-01
Acute injuries of the lateral ankle ligaments are one of the most common form of injury involving the musculoskeletal apparatus. Treatment usually range from cast immobilisation or acute surgical repair to functional rehabilitation. The aim of our study was to evaluate the incidence of different grades of acute injuries of lateral ligaments of the ankle joint in our patients group and to compare the results of non surgical versus surgical treatment of third grade injuries. 3148 patients were treated for acute lateral ankle sprain in a period of 5 years at our department. Each patient had stress X-ray of the ankle for evaluation of instability at the first visit. From the 234 patients with third grade injury, 39 were enrolled in our study with non surgical treatment and 18 with surgical treatment. Each group was divided regarding to the age in two subgroups. Functional outcome was evaluated 12 and 24 months after injury with AOFAS clinical rating scale and Sports Ankle Rating System--Single Assessment Numeric Evaluation. Statistical analysis was done with Pearson's Chi quadrate test with P < 0.05. First grade injury was present in 62%, second grade in 31% and only 7% of the patients had third grade injury of the lateral ankle ligaments. Further only third grade injuries were studied. Statistically significant better results were seen in patients under the age of 25, in the patient group with surgical treatment compared to patients over 25 years of age. Also statistically significant better results were seen in patient with surgical treatment to non surgical treatment in each age group. No significant difference was observed in the non surgical treatment group regarding to age. Although the injuries of the ankle ligaments belong to the most common injuries of the musculoskeletal system, there is no consensus in the treatment of such disorders. Our experiences and the results of our study show, that surgical treatment in indicated cases provides better results in residual pain and instability of the ankle joint after acute injury of the lateral ankle ligaments.;
Koop, S E; Winter, R B; Lonstein, J E
1984-03-01
In a retrospective review of the cases of thirteen skeletally immature children and adolescents (four to eighteen years old) with instability of the upper part of the cervical spine (occiput to fifth cervical vertebra), we determined the efficacy of posterior arthrodesis and halo-cast immobilization in the management of this condition. The patients were divided into two groups: those with congenital vertebral anomalies alone (fusion or structural defects, or both) and those with cervical anomalies and systemic disorders (dwarfism, juvenile rheumatoid arthritis, Down syndrome, and cerebral palsy). Two patterns of instability were found: instabilities at intervertebral joints adjacent to vertebral fusions, and instabilities located in vertebral defects. For all patients treatment included a posterior arthrodesis with external immobilization by a halo cast, and in two patients internal fixation with wire was also used. Solid arthrodesis was obtained in the twelve patients who were treated with autogenous grafts (iliac cancellous bone in eleven and rib bone in one), and a non-union developed in a child who was treated with bank-bone rib segments. Posterior cervical arthrodesis with wire fixation carries some risk of neural injury and often is not applicable in children with anomalous vertebrae. Spine fusion using delicate exposure, decortication using an air-drill, and placement of autogenous cancellous iliac grafts with external immobilization by a halo cast minimizes the risk of neural damage and is a reliable way to obtain a solid arthrodesis.
Dehghan, Niloofar; McKee, Michael D; Jenkinson, Richard J; Schemitsch, Emil H; Stas, Venessa; Nauth, Aaron; Hall, Jeremy A; Stephen, David J; Kreder, Hans J
2016-07-01
The aim of this study was to compare early weightbearing and range of motion (ROM) to nonweightbearing and immobilization in a cast after surgical fixation of unstable ankle fractures. Multicentre randomized controlled trial. Two-level one trauma centers. One hundred ten patients who underwent open reduction and internal fixation of an unstable ankle fracture were recruited and randomized. One of 2 rehabilitation protocols: (1) Early weightbearing (weightbearing and ROM at 2 weeks, Early WB) or (2) Late weightbearing (nonweightbearing and cast immobilization for 6 weeks, Late WB). The primary outcome measure was time to return to work (RTW). Secondary outcome measures included: ankle ROM, SF-36 heath outcome scores, Olerud/Molander ankle function score, and rates of complications. There was no difference in RTW. At 6 weeks postoperatively, patients in the Early WB group had significantly improved ankle ROM (41 vs. 29, P < 0.0001); Olerud/Molander ankle function scores (45 vs. 32, P = 0.0007), and SF-36 scores on both the physical (51 vs. 42, P = 0.008) and mental (66 vs. 54, P = 0.0008) components. There were no differences with regard to wound complications or infections and no cases of fixation failure or loss of reduction. Patients in the Late WB group had higher rates of planned/performed hardware removal due to plate irritation (19% vs. 2%, P = 0.005). Given the convenience for the patient, early improved functional outcome, and the lack of an increased complication rate, we recommend early postoperative weightbearing and ROM in patients with surgically treated ankle fractures. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
Rivara, Federico; Lumetti, Simone; Calciolari, Elena; Toffoli, Andrea; Forlani, Gianfranco; Manfredi, Edoardo
2016-06-01
The position of dental implants placed with software-guided systems should be highly accurate in order to ensure safety and a passive fit of the immediate prosthesis. The purpose of this study was to measure the discrepancy between the clinical and software-planned position of dental implants by applying a photogrammetric method. Two casts were obtained, 1 from the surgical template and 1 from the actual position of the implants on the alveolar ridge of a patient. Photogrammetry was then applied to precisely locate the position of each implant on the casts. Because this mathematical technique required the identification of image points and of the relative spatial coordinates, 4 marks were drilled on the implant screw. The position of the implants was then identified as the geometric center of the 4 marks, while the orientation of the implant axis was represented by a vector normal to the plane fitting the points. A series of 16 convergent images all around the object was made using a high-resolution digital camera. A mathematical method called "rototranslation" was used to superimpose the cast images for the comparison. The tests performed on the casts resulted in an average precision level of 4 μm for the locations and less than 1 degree for the axis of the implants. A series of empirical and numerical tests were performed to assess the performance of the procedure and of the measurement protocol. The photogrammetric method is reproducible and can be used to measure the discrepancy between the software-planned and the real position of dental implants. Considering that the average precision level required for an implant-based prosthesis is approximately 50 μm, the error associated with this method can be considered as negligible. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Chandrakanth, Udayakumar; Sudesh, Pebam; Gopinathan, NirmalRaj; Prakash, Mahesh; Goni, Vijay G
2016-01-01
Congenital talipes equinovarus (CTEV )/clubfoot is the most common congenital orthopedic condition. The success rate of Ponseti casting in the hands of the legend himself is not 100%. The prediction of difficult to correct foot and recurrences still remains a mystery to be solved. We all know that tarsal bones are dysplastic in clubfoot and considering it; we hypothesize that the amount of tarsal dysplasia can predict management duration and outcome. In literature we were not able to find studies that satisfactorily quantify the amount of tarsal dysplasia. Hence, it was considered worthwhile to quantify the amount of dysplasia in tarsal bone and to correlate these parameters with the duration and outcome of treatment by conventional method. A total of 25 infants with unilateral idiopathic clubfoot that have not taken any previous treatment were included in the study. An initial ultrasonography was done before start of treatment in 3 standard planes to measure the maximum length of 3 tarsal bones (talus, calcaneus, and navicular). Ponseti method of treatment was used; pirani scoring was done at each OPD (out patient department) visit. Number of casts required for complete correction and need for any surgical intervention were taken as the outcome parameters. We found that there is a significant correlation between number of casts required and the dysplasia of talus (α error=0.05). We also found a significant negative correlation between relative dysplasia of talus and number of casts required (r=-0.629 sig=0.001, r=-0.552 sig=0.004). Tarsal bone dysplasia as quantified by using ultrasonography can be used as a prognostic indicator in congenital idiopathic clubfoot. Although promising the method needs further studies and can be more useful after long-term follow-up where recurrences if any can be documented. Level II.
Sninsky, Brian C; Sehgal, Priyanka D; Hinshaw, J Louis; McDermott, John C; Nakada, Stephen Y
2014-07-01
We evaluated the efficacy of ureteroscopic therapy (electrohydraulic lithotripsy [EHL] and intraductal laser lithotripsy [ILL]) in patients with challenging biliary stones secondary to anatomic variations resulting from a previous surgical procedure, including liver transplantation. A retrospective chart review was performed for all patients with previous surgical alteration of the gastrointestinal (GI) tract who underwent EHL or ILL via peroral or percutaneous access for choledocholithiasis by a single surgeon at our institution from 2000 to 2012. A database containing clinical and surgical variables was created, and long-term follow-up was conducted (3-138 months; median, 99 months). Thirteen patients (51.7±20.0 years; M:F, 10:3) in whom endoscopic retrograde cholangiopancreatography (ERCP), percutaneous transhepatic cholangiography (PTHC), or both failed were identified. Failure of ERCP/PTHC was because of inaccessibility of the calculi in all cases. Stone clearance was achieved in 12/13 (93%) patients; 8/12 (62%) after one procedure, and 4/12 (31%) after two procedures. One patient with biliary cast syndrome needed four interventions over 9 years. Major complications were low, with only one patient with hypotension and cholangitis that resolved with 24 hours of administration of intravenous fluids and antibiotics. Both endoscopic and percutaneous lithotripsies are effective treatments for refractory biliary calculi resulting from the post-surgical GI tract. Although a staged second procedure may be necessary in patients with significant stone burden, this is significantly better than extensive open surgery.
Tran, Ngoc Hieu; Tantidhnazet, Syrina; Raocharernporn, Somchart; Kiattavornchareon, Sirichai; Pairuchvej, Verasak; Wongsirichat, Natthamet
2018-05-01
The benefit of computer-assisted planning in orthognathic surgery (OGS) has been extensively documented over the last decade. This study aimed to evaluate the accuracy of three-dimensional (3D) virtual planning in surgery-first OGS. Fifteen patients with skeletal class III malocclusion who underwent bimaxillary OGS with surgery-first approach were included. A composite skull model was reconstructed using data from cone-beam computed tomography and stereolithography from a scanned dental cast. Surgical procedures were simulated using Simplant O&O software, and the virtual plan was transferred to the operation room using 3D-printed splints. Differences of the 3D measurements between the virtual plan and postoperative results were evaluated, and the accuracy was reported using root mean square deviation (RMSD) and the Bland-Altman method. The virtual planning was successfully transferred to surgery. The overall mean linear difference was 0.88 mm (0.79 mm for the maxilla and 1 mm for the mandible), and the overall mean angular difference was 1.16°. The RMSD ranged from 0.86 to 1.46 mm and 1.27° to 1.45°, within the acceptable clinical criteria. In this study, virtual surgical planning and 3D-printed surgical splints facilitated the diagnosis and treatment planning, and offered an accurate outcome in surgery-first OGS.
Maxillary growth in a congenital cleft palate canine model for surgical research.
Paradas-Lara, Irene; Casado-Gómez, Inmaculada; Martín, Conchita; Martínez-Sanz, Elena; López-Gordillo, Yamila; González, Pablo; Rodríguez-Bobada, Cruz; Chamorro, Manuel; Arias, Pablo; Maldonado, Estela; Ortega, Ricardo; Berenguer, Beatriz; Martínez-Álvarez, Concepción
2014-01-01
We have recently presented the Old Spanish Pointer dog, with a 15-20% spontaneous congenital cleft palate rate, as a unique experimental model of this disease. This study aimed to describe the cleft palate of these dogs for surgical research purposes and to determine whether congenital cleft palate influences maxillofacial growth. Seven newborn Old Spanish Pointer dogs of both sexes, comprising a cleft palate group (n = 4) and a normal palate group (n = 3), were fed using the same technique. Macroscopic photographs and plaster casts from the palate, lateral radiographs and computer tomograms of the skull were taken sequentially over 41 weeks, starting at week 5. The cleft morphology, the size and the tissue characteristics in these dogs resembled the human cleft better than current available animal models. During growth, the cleft width varies. Most of the transverse and longitudinal measures of the palate were statistically lower in the cleft palate group. The cleft palate group showed hypoplasia of the naso-maxillary complex. This model of congenital cleft palate seems suitable for surgical research purposes. A reduced maxillofacial pre- and post-natal development is associated to the congenital cleft palate in the Old Spanish Pointer dog. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Patterson, Steve M; Picconatto, William J; Alexander, Julie A; Johnson, Rachel L
2011-01-01
To present the case of an acute traumatic extensor carpi ulnaris (ECU) subluxation in a National Collegiate Athletic Association Division II female basketball player. The ECU tendon is stabilized in the ulnar groove by a subsheath located inferior to the extensor retinaculum. The subsheath can be injured with forced supination, ulnar deviation, and wrist flexion, resulting in the ECU tendon subluxing in the palmar and ulnar directions during wrist circumduction. Several methods of intervention exist, but controversy remains on how to best treat this condition. Distal ulnar fracture, ulnar collateral ligament sprain, triangular fibrocartilage complex lesion, lunotriquetral instability, distal radioulnar joint injury, pisotriquetral joint injury, ECU tendinopathy or subluxation. The wrist was placed in a short-arm cast in slight extension and radial deviation for 4 weeks. At that time, the patient was still able to actively sublux the ECU tendon, so a long-arm cast was applied with the wrist in slight extension, radial deviation, and pronation for an additional 4 weeks. The ECU tendon was then found to be stable. She wore a rigid wrist brace for 3 more weeks while she pursued rehabilitation. At the final follow-up appointment, the ECU tendon remained stable, and the wrist was asymptomatic. Subluxations of the ECU are rare. If the patient does not improve with conservative measures, surgical intervention is warranted to repair the sixth dorsal compartment. A long-arm cast with the elbow flexed to 90° and the wrist in approximately 30° of extension, radial deviation, and pronation was appropriate treatment for this type of injury.
2011-01-01
Background A precise placement of dental implants is a crucial step to optimize both prosthetic aspects and functional constraints. In this context, the use of virtual guiding systems has been recognized as a fundamental tool to control the ideal implant position. In particular, complex periodontal surgeries can be performed using preoperative planning based on CT data. The critical point of the procedure relies on the lack of accuracy in transferring CT planning information to surgical field through custom-made stereo-lithographic surgical guides. Methods In this work, a novel methodology is proposed for monitoring loss of accuracy in transferring CT dental information into periodontal surgical field. The methodology is based on integrating 3D data of anatomical (impression and cast) and preoperative (radiographic template) models, obtained by both CT and optical scanning processes. Results A clinical case, relative to a fully edentulous jaw patient, has been used as test case to assess the accuracy of the various steps concurring in manufacturing surgical guides. In particular, a surgical guide has been designed to place implants in the bone structure of the patient. The analysis of the results has allowed the clinician to monitor all the errors, which have been occurring step by step manufacturing the physical templates. Conclusions The use of an optical scanner, which has a higher resolution and accuracy than CT scanning, has demonstrated to be a valid support to control the precision of the various physical models adopted and to point out possible error sources. A case study regarding a fully edentulous patient has confirmed the feasibility of the proposed methodology. PMID:21338504
Ploch, Caitlin C; Mansi, Chris S S A; Jayamohan, Jayaratnam; Kuhl, Ellen
2016-06-01
Three-dimensional (3D) printing holds promise for a wide variety of biomedical applications, from surgical planning, practicing, and teaching to creating implantable devices. The growth of this cheap and easy additive manufacturing technology in orthopedic, plastic, and vascular surgery has been explosive; however, its potential in the field of neurosurgery remains underexplored. A major limitation is that current technologies are unable to directly print ultrasoft materials like human brain tissue. In this technical note, the authors present a new technology to create deformable, personalized models of the human brain. The method combines 3D printing, molding, and casting to create a physiologically, anatomically, and tactilely realistic model based on magnetic resonance images. Created from soft gelatin, the model is easy to produce, cost-efficient, durable, and orders of magnitude softer than conventionally printed 3D models. The personalized brain model cost $50, and its fabrication took 24 hours. In mechanical tests, the model stiffness (E = 25.29 ± 2.68 kPa) was 5 orders of magnitude softer than common 3D printed materials, and less than an order of magnitude stiffer than mammalian brain tissue (E = 2.64 ± 0.40 kPa). In a multicenter surgical survey, model size (100.00%), visual appearance (83.33%), and surgical anatomy (81.25%) were perceived as very realistic. The model was perceived as very useful for patient illustration (85.00%), teaching (94.44%), learning (100.00%), surgical training (95.00%), and preoperative planning (95.00%). With minor refinements, personalized, deformable brain models created via 3D printing will improve surgical training and preoperative planning with the ultimate goal to provide accurate, customized, high-precision treatment. Copyright © 2016 Elsevier Inc. All rights reserved.
Raffat, Arsalah; Ijaz, Abida
2009-06-01
To determine retraction and alignment of protruded and rotated premaxillary segment and to measure increase in columellar length by using modified orthopaedic plate with anterior acrylic ring in newborn babies with non syndromic bilateral cleft lip and palate. Pre surgical infant orthopaedic treatment of ten non syndromic bilateral cleft lip and palate new born babies was done. Modified orthopaedic plate with anterior acrylic ring was used. This was adjusted every week by adding increments of 1 mm acrylic along the inner surface contacting labial surface of pre maxillary segment and trimming the same amount along the anterior margin of the plate. Pre and post treatment dental cast and a 1:1 photocopy of dental cast was obtained to analyze the retraction, angulations and arch form. Data was compiled and analyzed in SPSS 10. A significant pre maxillary retraction, correction of rotation as well as increase of columellar length was achieved. The appliance proved most successful being used immediately after birth, making use of plasticity of the neonate cartilage due to maternal estrogen levels. Moreover the appliance maintained arch form facilitated function and rendered initial lip repair easy and tension free.
2014-01-01
Background Ankle fractures account for 9% of all fractures with a quarter of these occurring in adults over 60 years. The short term disability and long-term consequences of this injury can be considerable. Current opinion favours open reduction and internal fixation (ORIF) over non-operative treatment (fracture manipulation and the application of a standard moulded cast) for older people. Both techniques are associated with complications but the limited published research indicates higher complication rates of fracture malunion (poor position at healing) with casting. The aim of this study is to compare ORIF with a modification of existing casting techniques, Close Contact Casting (CCC). We propose that CCC may offer an equivalent functional outcome to ORIF and avoid the risks associated with surgery. Methods/Design This study is a pragmatic multi-centre equivalence randomised controlled trial. 620 participants will be randomised to receive ORIF or CCC after sustaining an isolated displaced unstable ankle fracture. Participants will be recruited from a minimum of 20 National Health Service (NHS) acute hospitals throughout England and Wales. Participants will be aged over 60 years and be ambulatory prior to injury. Follow-up will be at six weeks and six months after randomisation. The primary outcome is the Olerud & Molander Ankle Score, a functional patient reported outcome measure, at 6 months. Follow-up will also include assessments of mobility, ankle range of movement, health related quality of life and complications. The six-month follow-up will be conducted face-to-face by an assessor blinded to the allocated intervention. A parallel economic evaluation will consider both a health service and a broader societal perspective including the individual and their family. In order to explore patient experience of their treatment and recovery, a purposive sample of 40 patients will also be interviewed using a semi-structured interview schedule between 6-10 weeks post treatment. Discussion This multicentre study was open to recruitment July 2010 and recruitment is due to be completed in December 2013. Trial registration Current Controlled Trials ISRCTN04180738. PMID:24621174
A Review of Brachial Plexus Birth Palsy: Injury and Rehabilitation.
Raducha, Jeremy E; Cohen, Brian; Blood, Travis; Katarincic, Julia
2017-11-01
Brachial plexus injuries during the birthing process can leave infants with upper extremity deficits corresponding to the location of the lesion within the complex plexus anatomy. Manifestations can range from mild injuries with complete resolution to severe and permanent disability. Overall, patients have a high rate of spontaneous recovery (66-92%).1,2 Initially, all lesions are managed with passive range motion and observation. Prevention and/or correction of contractures with occupational therapy and serial splinting/casting along with encouraging normal development are the main goals of non-operative treatment. Surgical intervention may be war- ranted, depending on functional recovery. [Full article available at http://rimed.org/rimedicaljournal-2017-11.asp].
[Treatment of metacarpal fractures].
Prokop, A; Jubel, A; Helling, H J; Kulus, S; Rehm, K E
2002-09-01
Conservative treatment of metacarpal fractures is recommended if there is no joint displacement, malrotation, displacement of over 30 degrees ad axim and shortening of over 5 mm. Surgery should be performed in open fractures and serial fractures of metacarpal bone. Early functional treatment should be carried out in stable, not displaced fractures. A cast can be used for a short period in full extended position of fingers and flexion in metacarpo-phalangeal joint in 60 - 90 degrees. Twin-tape fixation allows functional treatment after soft-tissue swelling has disappeared. Closed reduction of displaced fractures of the fifth metacarpal bone (boxer's fracture) is not successful. Cases with displacement of over 30 degrees may be treated surgically by intramedullary stabilisation.
Effect of Casting Material on the Cast Pressure After Sequential Cast Splitting.
Roberts, Aaron; Shaw, K Aaron; Boomsma, Shawn E; Cameron, Craig D
2017-01-01
Circumferential casting is a vital component of nonoperative fracture management. These casts are commonly valved to release pressure and decrease the risk of complications from swelling. However, little information exists regarding the effect of different casting supplies on the pressure within the cast. Seventy-five long-arm casts were performed on human volunteers, divided between 5 experimental groups with 15 casts in each groups. Testing groups consisted of 2 groups with a plaster short-arm cast overwrapped with fiberglass to a long arm with either cotton or synthetic cast padding. The 3 remaining groups included fiberglass long-arm casts with cotton, synthetic, or waterproof cast padding. A pediatric blood pressure cuff bladder was placed within the cast and inflated to 100 mm Hg. After inflation, the cast was sequentially released with pressure reading preformed after each stage. Order of release consisted of cast bivalve, cast padding release, and cotton stockinet release. After release, the cast was overwrapped with a loose elastic bandage. Difference in pressure readings were compared based upon the cast material. Pressures within the cast were found to decrease with sequential release of cast. The cast type had no effect of change in pressure. Post hoc testing demonstrated that the type of cast padding significantly affected the cast pressures with waterproof padding demonstrating the highest pressure readings at all time-points in the study, followed by synthetic padding. Cotton padding had the lowest pressure readings at all time-points. Type of cast padding significantly influences the amount of pressure within a long-arm cast, even after bivalving the cast and cutting the cast padding. Cotton cast padding allows for the greatest change in pressure. Cotton padding demonstrates the greatest change in pressure within a long-arm cast after undergoing bivalve. Synthetic and waterproof cast padding should not be used in the setting of an acute fracture to accommodate swelling.
Reddy, S Srikanth; Revathi, Kakkirala; Reddy, S Kranthikumar
2013-01-01
Conventional casting technique is time consuming when compared to accelerated casting technique. In this study, marginal accuracy of castings fabricated using accelerated and conventional casting technique was compared. 20 wax patterns were fabricated and the marginal discrepancy between the die and patterns were measured using Optical stereomicroscope. Ten wax patterns were used for Conventional casting and the rest for Accelerated casting. A Nickel-Chromium alloy was used for the casting. The castings were measured for marginal discrepancies and compared. Castings fabricated using Conventional casting technique showed less vertical marginal discrepancy than the castings fabricated by Accelerated casting technique. The values were statistically highly significant. Conventional casting technique produced better marginal accuracy when compared to Accelerated casting. The vertical marginal discrepancy produced by the Accelerated casting technique was well within the maximum clinical tolerance limits. Accelerated casting technique can be used to save lab time to fabricate clinical crowns with acceptable vertical marginal discrepancy.
A Unique Bonding Technique for Immediate Orthognathic Surgery
Ayinipully, Hariprasad; Paul, Rosaline Tina; Ponnambathayil, Shaji Aboobacker; Rasheed, Althaf Thanimoottil
2015-01-01
Introduction A challenge in orthodontics is achieving ideal bracket position which determines treatment results and finishing. A new bonding method is done indirectly on the cast and bonded directly on the teeth, but it does not require conventional trays to carry the brackets to the teeth. Materials and Methods Heavy sized archwires like 0.019″x0.025″ or 0.018″ SS are bent to the malocclusion to generate a template which comprises of an Bracket -Archwire Assembly (BAA). This assembly is transferred onto the teeth using the molar bands with tubes which serves as a jig for proper orientation of the BAA, then the adhesive is cured at one shot to complete the bonding procedure. Results Two surgical cases successfully bonded with this technique is presented in this article. Conclusion This bonding method finds specific advantages in surgical orthodontics – when the surgeon decides on a surgery-first treatment objective, management of single or a couple of periodontally extruded teeth, management of impacted teeth and in patients needing fixed functional appliance immediately before the completion of growth spurt. PMID:26266212
Assessment of "YouTube" Content for Distal Radius Fracture Immobilization.
Addar, Abdullah; Marwan, Yousef; Algarni, Nizar; Berry, Gregory
Distal radius fractures (DRFs) are the most common orthopedic fractures, with >70% of cases treated by closed immobilization using a short arm cast or a sugar tong splint. However, inadequate immobilization is a risk factor for loss of reduction requiring repeat reduction or surgical treatment. Therefore, education of clinical skills for appropriate immobilization of DRFs is important. With the increasing use of web-based information by medical learners, our aim was to assess the quality and quantity of videos regarding closed immobilization of DRFs on YouTube. Retrospective review of YouTube videos on distal radius fracture immobilization using specific search terms. Identified videos were analyzed for their educational value, quality of the technical skill demonstrated, and overall metrics. Educational value was scored on a 5-point scale, with "1" indicative of low quality and "5" of high quality. Not applicable. Among the 68,366 videos identified, 16 met our inclusion criteria of being in English; performed by a health care professional or institution; and with casting being the major theme of the educational information provided. Of these 16 videos, 6 had an educational value score of 4 or 5, with the remaining 10 having a score ≤3. Although immobilization was demonstrated by cast technician specialized in orthopedics, skills were also performed by orthopedic attendants, urgent care physicians, orthopedic residents, and nurse practitioners. The credentials of the performer in 3 videos were not identified. There is a need to promote high-quality educational videos produced by established medical school faculty members on open, web-based, portals. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Renard, Yohann; Hossu, Gabriela; Chen, Bailiang; Krebs, Marine; Labrousse, Marc; Perez, Manuela
2018-01-01
The objective of this study was to develop a simple and useful injection protocol for imaging cadaveric vascularization and dissection. Mixtures of contrast agent and cast product should provide adequate contrast for two types of ex vivo imaging (MRI and CT) and should harden to allow gross dissection of the injected structures. We tested the most popular contrast agents and cast products, and selected the optimal mixture composition based on their availability and ease of use. All mixtures were first tested in vitro to adjust dilution parameters of each contrast agent and to fine-tune MR imaging acquisition sequences. Mixtures were then injected in 24 pig livers and one human pancreas for MR and computed tomography (CT) imaging before anatomical dissection. Colorized latex, gadobutrol and barite mixture met the above objective. Mixtures composed of copper sulfate (CuSO 4 ) gadoxetic acid (for MRI) and iodine (for CT) gave an inhomogeneous signal or extravasation of the contrast agent. Agar did not harden sufficiently for gross dissection but appears useful for CT and magnetic resonance imaging (MRI) studies without dissection. Silicone was very hard to inject but achieved the goals of the study. Resin is particularly difficult to use but could replace latex as an alternative for corrosion instead of dissection. This injection protocol allows CT and MRI images to be obtained of cadaveric vascularization and anatomical casts in the same anatomic specimen. Post-imaging processing software allow easy 3D reconstruction of complex anatomical structures using this technique. Applications are numerous, e.g. surgical training, teaching methods, postmortem anatomic studies, pathologic studies, and forensic diagnoses. © 2017 Anatomical Society.
Tran, Ngoc Hieu; Tantidhnazet, Syrina; Raocharernporn, Somchart; Kiattavornchareon, Sirichai; Pairuchvej, Verasak; Wongsirichat, Natthamet
2018-01-01
Background The benefit of computer-assisted planning in orthognathic surgery (OGS) has been extensively documented over the last decade. This study aimed to evaluate the accuracy of three-dimensional (3D) virtual planning in surgery-first OGS. Methods Fifteen patients with skeletal class III malocclusion who underwent bimaxillary OGS with surgery-first approach were included. A composite skull model was reconstructed using data from cone-beam computed tomography and stereolithography from a scanned dental cast. Surgical procedures were simulated using Simplant O&O software, and the virtual plan was transferred to the operation room using 3D-printed splints. Differences of the 3D measurements between the virtual plan and postoperative results were evaluated, and the accuracy was reported using root mean square deviation (RMSD) and the Bland-Altman method. Results The virtual planning was successfully transferred to surgery. The overall mean linear difference was 0.88 mm (0.79 mm for the maxilla and 1 mm for the mandible), and the overall mean angular difference was 1.16°. The RMSD ranged from 0.86 to 1.46 mm and 1.27° to 1.45°, within the acceptable clinical criteria. Conclusion In this study, virtual surgical planning and 3D-printed surgical splints facilitated the diagnosis and treatment planning, and offered an accurate outcome in surgery-first OGS. PMID:29581806
Costa, Vania; Tu, Hong Anh; Wells, David; Weir, Mark; Holubowich, Corinne; Walter, Melissa
2017-01-01
Background Diabetic neuropathic foot ulcers are a risk factor for lower leg amputation. Many experts recommend offloading with fibreglass total contact casting, removable cast walkers, and irremovable cast walkers as a way to treat these ulcers. Methods We completed a health technology assessment, which included an evaluation of clinical benefits and harms, value for money, and patient preferences for offloading devices. We performed a systematic literature search on August 17, 2016, to identify randomized controlled trials that compared fibreglass total contact casting, removable cast walkers, and irremovable cast walkers with other treatments (offloading or non-offloading) in patients with diabetic neuropathic foot ulcers. We developed a decision-analytic model to assess the cost-effectiveness of fibreglass total contact casting, removable cast walkers, and irremovable cast walkers, and we conducted a 5-year budget impact analysis. Finally, we interviewed people with diabetes who had lived experience with foot ulcers, asking them about the different offloading devices and the factors that influenced their treatment choices. Results We identified 13 randomized controlled trials. The evidence suggests that total contact casting, removable cast walkers, and irremovable cast walkers are beneficial in the treatment of neuropathic, noninfected foot ulcers in patients with diabetes but without severe peripheral arterial disease. Compared to removable cast walkers, ulcer healing was improved with total contact casting (moderate quality evidence; risk difference 0.17 [95% confidence interval 0.00–0.33]) and irremovable cast walkers (low quality evidence; risk difference 0.21 [95% confidence interval 0.01–0.40]). We found no difference in ulcer healing between total contact casting and irremovable cast walkers (low quality evidence; risk difference 0.02 [95% confidence interval −0.11–0.14]). The economic analysis showed that total contact casting and irremovable cast walkers were less expensive and led to more health outcome gains (e.g., ulcers healed and quality-adjusted life-years) than removable cast walkers. Irremovable cast walkers were as effective as total contact casting and were associated with lower costs. The 5-year budget impact of funding total contact casting, removable cast walkers, and irremovable cast walkers (device costs only at 100% access) would be $17 to $20 million per year. The patients we interviewed felt that wound healing was improved with total contact casting than with removable cast walkers, but that removable cast walkers were more convenient and came with a lower cost burden. They reported no experience or familiarity with irremovable cast walkers. Conclusions Ulcer healing improved with total contact casting, irremovable cast walkers, and removable cast walkers, but total contact casting and irremovable cast walkers had higher rates of ulcer healing than removable cast walkers. Increased access to offloading devices could result in cost savings for the health system because of fewer amputations. Patients with diabetic foot ulcers reported a preference for total contact casting over removable cast walkers, largely because they perceived wound healing to be improved with total contact casting. However, cost, comfort, and convenience are concerns for patients. PMID:28989556
2017-01-01
Diabetic neuropathic foot ulcers are a risk factor for lower leg amputation. Many experts recommend offloading with fibreglass total contact casting, removable cast walkers, and irremovable cast walkers as a way to treat these ulcers. We completed a health technology assessment, which included an evaluation of clinical benefits and harms, value for money, and patient preferences for offloading devices. We performed a systematic literature search on August 17, 2016, to identify randomized controlled trials that compared fibreglass total contact casting, removable cast walkers, and irremovable cast walkers with other treatments (offloading or non-offloading) in patients with diabetic neuropathic foot ulcers. We developed a decision-analytic model to assess the cost-effectiveness of fibreglass total contact casting, removable cast walkers, and irremovable cast walkers, and we conducted a 5-year budget impact analysis. Finally, we interviewed people with diabetes who had lived experience with foot ulcers, asking them about the different offloading devices and the factors that influenced their treatment choices. We identified 13 randomized controlled trials. The evidence suggests that total contact casting, removable cast walkers, and irremovable cast walkers are beneficial in the treatment of neuropathic, noninfected foot ulcers in patients with diabetes but without severe peripheral arterial disease. Compared to removable cast walkers, ulcer healing was improved with total contact casting (moderate quality evidence; risk difference 0.17 [95% confidence interval 0.00-0.33]) and irremovable cast walkers (low quality evidence; risk difference 0.21 [95% confidence interval 0.01-0.40]). We found no difference in ulcer healing between total contact casting and irremovable cast walkers (low quality evidence; risk difference 0.02 [95% confidence interval -0.11-0.14]). The economic analysis showed that total contact casting and irremovable cast walkers were less expensive and led to more health outcome gains (e.g., ulcers healed and quality-adjusted life-years) than removable cast walkers. Irremovable cast walkers were as effective as total contact casting and were associated with lower costs. The 5-year budget impact of funding total contact casting, removable cast walkers, and irremovable cast walkers (device costs only at 100% access) would be $17 to $20 million per year. The patients we interviewed felt that wound healing was improved with total contact casting than with removable cast walkers, but that removable cast walkers were more convenient and came with a lower cost burden. They reported no experience or familiarity with irremovable cast walkers. Ulcer healing improved with total contact casting, irremovable cast walkers, and removable cast walkers, but total contact casting and irremovable cast walkers had higher rates of ulcer healing than removable cast walkers. Increased access to offloading devices could result in cost savings for the health system because of fewer amputations. Patients with diabetic foot ulcers reported a preference for total contact casting over removable cast walkers, largely because they perceived wound healing to be improved with total contact casting. However, cost, comfort, and convenience are concerns for patients.
Coetzee, Johann F; Gehring, Ronette; Tarus-Sang, Jepkoech; Anderson, David E
2010-11-01
To describe the pharmacokinetics, cortisol response and behavioral changes associated with administration of sub-anesthetic xylazine and ketamine prior to castration. Prospective, randomized experiment. Twenty-two male beef calves (260-310 kg). Calves were randomly assigned to receive the following treatment immediately prior to surgical or simulated castration; 1) uncastrated, placebo-treated control (CONT) (n=4),2) Castrated, placebo treated control (CAST) (n=6), 3) castrated with intravenous xylazine (X) (0.05 mg kg(-1)) (n=6), and 4) castrated with IV xylazine (X) (0.05 mg kg(-1) ) combined with ketamine (K) (0.1 mg kg(-1)) (n=6). Blood samples collected over 10 hours post-castration were analyzed by LC-MS-MS for drug concentrations and chemiluminescent immunoassay for cortisol determination. Drug concentrations during the first 60 minutes post-castration fit a one-compartment open model with first-order elimination. The harmonic mean elimination half-lives (± pseudo SD) for X, X with K and K were 12.9 ± 1.2, 11.2 ± 3.1 and 10.6 ± 2.8 minutes, respectively. The proportion of the total area under the effect curve (AUEC) for cortisol during this period was significantly lower in the X group (13 ± 3%; p=0.006) and the X+K group (14 ± 2%; p=0.016) compared with the CAST calves (21 ± 2%). However, after 300 minutes the AUEC in the X group was higher than CAST. Significantly more calves demonstrated attitude that was unchanged from pre-manipulation behavior in the CONT (p=0.021) and X+K treated calves (p=0.0051) compared with the CAST calves. Behavioral changes and lower serum cortisol concentrations during the first 60 minutes post-castration were associated with quantifiable xylazine and ketamine concentrations. Low doses of xylazine and ketamine administered immediately prior to castration may offer a safe, efficacious and cost-effective systemically administered alternative or adjunct to local anesthesia. © 2010 The Authors. Veterinary Anaesthesia and Analgesia © 2010 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesiologists.
Soft cast versus rigid cast for treatment of distal radius buckle fractures in children.
Witney-Lagen, Caroline; Smith, Christine; Walsh, Graham
2013-04-01
Buckle fractures are extremely common and their optimum management is still under debate. This study aimed to ascertain whether buckle fractures of the distal radius can be safely and effectively treated in soft cast with only a single orthopaedic outpatient clinic appointment. A total of 232 children with buckle fractures of the distal radius were included in the study. 111 children with 112 distal radius fractures were treated in full rigid cast and 121 children with 123 fractures were treated with soft cast. The rigid cast children attended outpatient clinic for removal of cast at 3 weeks. Soft casts were removed by parents unwinding the cast at home after 3 weeks. Follow-up was conducted prospectively by telephone questionnaire at an average of 6 weeks post-injury. Outcome data were available for 117 children treated in soft cast and for 102 children treated in rigid cast. The most common mechanism of injury was a fall sustained from standing or running, followed by falls from bikes and then trampoline accidents. Overall, both groups recovered well. Overall satisfaction with the outcome of treatment was 97.4% in soft cast and 95.2% in rigid cast. Casts were reported as comfortable by 95.7% in soft cast and 93.3% in rigid cast. Cast changes were required for 6.8% of soft casts and 11.5% of rigid casts. The most frequent cause for changing rigid casts was getting the cast wet. None of the improved scores seen in the soft cast group were statistically significant. No re-fractures were seen in either group. Nearly all (94.9%) children in soft cast did bathe, shower or swim in their cast. Parents of both groups preferred treatment with soft cast (p < 0.001). Reasons given for preferring the soft cast included the ability to get the cast wet, avoidance of the plaster saw and not having to take time off work to attend a follow-up visit for cast removal. Buckle fractures of the distal radius can be safely and effectively treated in soft cast with only a single orthopaedic outpatient clinic appointment. Copyright © 2012 Elsevier Ltd. All rights reserved.
3D printed mitral valve models: affordable simulation for robotic mitral valve repair.
Premyodhin, Ned; Mandair, Divneet; Ferng, Alice S; Leach, Timothy S; Palsma, Ryan P; Albanna, Mohammad Z; Khalpey, Zain I
2018-01-01
3D printed mitral valve (MV) models that capture the suture response of real tissue may be utilized as surgical training tools. Leveraging clinical imaging modalities, 3D computerized modelling and 3D printing technology to produce affordable models complements currently available virtual simulators and paves the way for patient- and pathology-specific preoperative rehearsal. We used polyvinyl alcohol, a dissolvable thermoplastic, to 3D print moulds that were casted with liquid platinum-cure silicone yielding flexible, low-cost MV models capable of simulating valvular tissue. Silicone-moulded MV models were fabricated for 2 morphologies: the normal MV and the P2 flail. The moulded valves were plication and suture tested in a laparoscopic trainer box with a da Vinci Si robotic surgical system. One cardiothoracic surgery fellow and 1 attending surgeon qualitatively evaluated the ability of the valves to recapitulate tissue feel through surveys utilizing the 5-point Likert-type scale to grade impressions of the valves. Valves produced with the moulding and casting method maintained anatomical dimensions within 3% of directly 3D printed acrylonitrile butadiene styrene controls for both morphologies. Likert-type scale mean scores corresponded with a realistic material response to sutures (5.0/5), tensile strength that is similar to real MV tissue (5.0/5) and anatomical appearance resembling real MVs (5.0/5), indicating that evaluators 'agreed' that these aspects of the model were appropriate for training. Evaluators 'somewhat agreed' that the overall model durability was appropriate for training (4.0/5) due to the mounting design. Qualitative differences in repair quality were notable between fellow and attending surgeon. 3D computer-aided design, 3D printing and fabrication techniques can be applied to fabricate affordable, high-quality educational models for technical training that are capable of differentiating proficiency levels among users. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Ponseti method in the management of clubfoot under 2 years of age: A systematic review
Luximon, Ameersing; Al-Jumaily, Adel; Balasankar, Suchita Kothe; Naik, Ganesh R.
2017-01-01
Background Congenital talipes equinovarus (CTEV), also known as clubfoot, is common congenital orthopedic foot deformity in children characterized by four components of foot deformities: hindfoot equinus, hindfoot varus, midfoot cavus, and forefoot adduction. Although a number of conservative and surgical methods have been proposed to correct the clubfoot deformity, the relapses of the clubfoot are not uncommon. Several previous literatures discussed about the technical details of Ponseti method, adherence of Ponseti protocol among walking age or older children. However there is a necessity to investigate the relapse pattern, compliance of bracing, number of casts used in treatment and the percentages of surgical referral under two years of age for clear understanding and better practice to achieve successful outcome without or reduce relapse. Therefore this study aims to review the current evidence of Ponseti method (manipulation, casting, percutaneous Achilles tenotomy, and bracing) in the management of clubfoot under two years of age. Materials and methods Articles were searched from 2000 to 2015, in the following databases to identify the effectiveness of Ponseti method treatment for clubfoot: Medline, Cumulative Index to Nursing and Allied Health Literature (CINHAL), PubMed, and Scopus. The database searches were limited to articles published in English, and articles were focused on the effectiveness of Ponseti method on children with less than 2 years of age. Results Of the outcome of 1095 articles from four electronic databases, twelve articles were included in the review. Pirani scoring system, Dimeglio scoring system, measuring the range of motion and rate of relapses were used as outcome measures. Conclusions In conclusion, all reviewed, 12 articles reported that Ponseti method is a very effective method to correct the clubfoot deformities. However, we noticed that relapses occur in nine studies, which is due to the non-adherence of bracing regime and other factors such as low income and social economic status. PMID:28632733
Alanazi, Reham Muqbil; Alanazi, Ashjan Aqeel; Alenezi, Ibtihaj Qaseem; Alsulobi, Anwar Matar; Almutairy, Abdulrhman Fahad; Ali, Wafaa Mohamed Bakr; Alanazi, Mohammed Abdullah; Alkhidhr, Mohammed Abdullah; Elfetoh, Nagah Mohamed Abo; Ali, Abdalla Mohamed Bakr
2017-01-01
Background Deep venous thrombosis (DVT) is a condition that occurs frequently among surgical, as well as acutely ill hospitalized medical patients, and is responsible for significant morbidity and mortality in hospitalized patients. Risk factors include older age, surgery and immobilization (as with bed rest, orthopedic casts, and sitting on long flights. Objective This study was conducted to identify the frequency and factors associated with occurrence of DVT among elderly patients referred to King Abdulaziz University (KAU) Hospital, Jeddah, Kingdom of Saudi Arabia. Methods The current study is a hospital based cross sectional study. The emergency, inpatients and outpatients’ departments at KAU hospital were reviewed. We studied all the referred elderly subjects during the study period. All elderly patients (540) referred to or admitted to the hospital departments and who were clinically suspected to have DVT and subjected to Doppler examination were included in the study. Data were analyzed using descriptive statistics and Chi square test. Results Based on the results of Doppler examination, DVT was detected in 97 (18.0%) of the studied elderly population. There were no significant differences in gender between patients who developed DVT and those who were negative by Doppler examination (p=0.018). Other comorbidities as diabetes, IHD and hypertension were significantly associated with the occurrence of DVT among the participants (p=0.05, 0.05 and 0.04 respectively). Furthermore, the other investigated factors such as being bed ridden, cancer, orthopedic cast and previous DVT were not significantly associated with the development of DVT among the studied elderly patients (p=0.42, 0.16, 0.45 and 0.75 respectively). Conclusion DVT has high prevalence in Jeddah; KSA. Thrombophilia screening should be regular for elderly patients with diabetes, hypertension and bed-ridden patients with recurrent DVT or patients with other risk factors. Knowing the most common risk factors and their significance in developing DVT is essential for early detection of DVT to prevent unwanted complications for elderlies. PMID:29403615
Incidence and etiology of unplanned cast changes for fractures in the pediatric population.
DiPaola, Matthew J; Abzug, Joshua M; Pizzutillo, Peter D; Herman, Martin J
2014-09-01
The majority of pediatric fractures are treated in casts due to the child's ability to heal rapidly and remodel. Unplanned cast changes are a time and economic burden with potentially adverse effects on fracture management. The purpose of this study is to document the incidence, etiology, and complications related to unplanned cast changes. A prospective study was conducted over a 6-month period to determine the incidence of unplanned cast changes. All casts applied were nonwaterproof. Data collected include the reason for cast placement, type of cast placed, duration of wear before the unplanned change, reason for the unplanned change, experience level of the original cast applicator, and cast-related complications. A total of 1135 casts were placed with 58% placed by a resident, 38% by a cast technician, 2% by a physician's assistant, and 2% by an attending physician. Sixty casts (5.3%) required an unplanned change including 19 short-arm casts, 18 short-leg casts, 17 long-arm casts, 4 thumb spica casts, and 2 long-leg casts. The average duration from cast application until the unplanned change was 13 days. Twenty-eight (47%) were changed for wetness, 20 (33%) for wear/breakage, 2 (3%) for skin irritation, and 10 (17%) for other reasons including objects in the cast and patient self-removal. Two patients had superficial skin infections requiring oral antibiotics. No fracture reductions were lost secondary to an unplanned cast change. The need for an unplanned cast change did not correlate with the level of experience of the applicator. Most unplanned cast changes were the result of patient nonadherence to instructions and not related to cast application technique. Improved patient and family education regarding cast care may reduce the frequency of unplanned cast changes, thus reducing an economic and time burden on the health care system. Level II--prognostic study.
Difazio, Rachel L; Harris, Marie; Feldman, Lanna; Mahan, Susan T
2017-12-01
Cast immobilization remains the mainstay of pediatric orthopaedic care, yet little is known about the incidence of cast-related skin complications in children treated with cast immobilization. The purposes of this quality improvement project were to: (1) establish a baseline rate of cast-related skin complications in children treated with cast immobilization, (2) identify trends in children who experienced cast-related skin complications, (3) design an intervention aimed at decreasing the rate of cast-related skin complications, and (4) determine the effectiveness of the intervention. A prospective interrupted time-series design was used to determine the incidence of cast-related skin complications overtime and compare the rates of skin complications before and after an intervention designed to decrease the incidence of cast-related heel complications. All consecutive patients who were treated with cast immobilization from September 2012 to September 2014 were included. A cast-related skin complications data collection tool was used to capture all cast-related skin complications. A high rate of heel events was noted in our preliminary analysis and an intervention was designed to decrease the rate of cast-related skin complications, including the addition of padding during casting and respective provider education. The estimated cast-related skin events rate for all patients was 8.9 per 1000 casts applied. The rate for the total preintervention sample was 13.6 per 1000 casts which decreased to 6.6 in the postintervention sample. When examining the heel-only group, the rate was 17.1 per 1000 lower extremity casts applied in the preintervention group and 6.8 in the postintervention group. Incorporating padding to the heel of lower extremity cast was an effective intervention in decreasing the incidence of cast-related skin complications in patients treated with cast immobilization. Level II.
Comparison of three facebow/semi-adjustable articulator systems for planning orthognathic surgery.
O'Malley, A M; Milosevic, A
2000-06-01
Our aim was to measure the steepness of the occlusal plane produced by three different semi-adjustable articulators: the Dentatus Type ARL, Denar MkII, and the Whipmix Quickmount 8800, and to assess the influence of possible systematic errors in positioning of study casts on articulators that are used to plan orthognathic surgery. Twenty patients (10 skeletal class II, and 10 skeletal class III) who were having pre-surgical orthodontics at Liverpool University Dental Hospital were studied. The measurement of the steepness of the occlusal plane was taken as the angle between the facebow bite-fork and the horizontal arm of the articulator. This was compared with the angle of the maxillary occlusal plane to the Frankfort plane as measured on lateral cephalometry (the gold standard). The Whipmix was closest to the gold standard as it flattened the occlusal plane by only 2 degrees (P<0.05). The results of the Denar and Dentatus differed significantly from those of the cephalogram as they flattened the occlusal plane by 5 degrees and 6. 5 degrees (P<0.01), respectively. Clinicians are encouraged to verify the steepness of the occlusal plane on mounted study casts before the technician makes the model. Copyright 2000 The British Association of Oral and Maxillofacial Surgeons.
Determining casting defects in near-net shape casting aluminum parts by computed tomography
NASA Astrophysics Data System (ADS)
Li, Jiehua; Oberdorfer, Bernd; Habe, Daniel; Schumacher, Peter
2018-03-01
Three types of near-net shape casting aluminum parts were investigated by computed tomography to determine casting defects and evaluate quality. The first, second, and third parts were produced by low-pressure die casting (Al-12Si-0.8Cu-0.5Fe-0.9Mg-0.7Ni-0.2Zn alloy), die casting (A356, Al-7Si-0.3Mg), and semi-solid casting (A356, Al-7Si-0.3Mg), respectively. Unlike die casting (second part), low-pressure die casting (first part) significantly reduced the formation of casting defects (i.e., porosity) due to its smooth filling and solidification under pressure. No significant casting defect was observed in the third part, and this absence of defects indicates that semi-solid casting could produce high-quality near-net shape casting aluminum parts. Moreover, casting defects were mostly distributed along the eutectic grain boundaries. This finding reveals that refinement of eutectic grains is necessary to optimize the distribution of casting defects and reduce their size. This investigation demonstrated that computed tomography is an efficient method to determine casting defects in near-net shape casting aluminum parts.
Moulin, N; François, I; Coté, N; Alford, C; Cleary, O; Desjardins, M R
2018-01-19
Despite the recommendation of plate fixation for propagating condylar fractures of the third metacarpal (McIII) or third metatarsal bone (MtIII), lag screw fixation can be a viable surgical option. To evaluate short-term outcome and long-term racing performance of horses that underwent lag screw fixation of long condylar fractures of the McIII/MtIII. Retrospective case series. Medical records, post-surgical racing performance and outcome of 26 horses with propagating fractures of the medial and/or lateral condyle of McIII/MtIII were reviewed. Medical information included were age, breed, sex, physical examination at admission, circumstances of fracture, radiographic evaluation, anaesthesia and recovery records, surgical and post-operative management, as well as complications. Outcome included racing data and information from telephone interviews. Twenty-six horses (9 Standardbreds and 17 Thoroughbreds) were admitted with a long condylar fracture of the McIII/MtIII. Fore- and hindlimbs were equally represented with the left hindlimb being more frequently involved. Most of the fractures had a spiralling component (76%) and four (15%) were comminuted. Fifteen (58%) horses raced post-surgery including nine Standardbreds (100%) and six Thoroughbreds (35%). Twelve of them were placed in at least one race and 11 won at least once. One horse sustained a severe complication in recovery. No significant difference was observed in the racing performances before and after surgery. Follow-up method and duration were not standardised and there is a low number of cases with six surgeons. Long condylar fractures can be repaired using lag fashion technique combined with a half-limb or full-limb tight cast for recovery as a good surgical alternative. Similar results to plate fixation can be expected, with a return to racing of more than 50%, and the prognosis being even better for pacers. © 2018 EVJ Ltd.
... tubular epithelial casts; Waxy casts; Casts in the urine; Fatty casts; Red blood cell casts; White blood ... The urine sample you provide may need to be from your first morning urine. The sample needs to be ...
ERIC Educational Resources Information Center
Wright, Michael D.; And Others
1992-01-01
Three articles discuss (1) casting technology as it relates to industry, with comparisons of shell casting, shell molding, and die casting; (2) evaporative pattern casting for metals; and (3) high technological casting with silicone rubber. (JOW)
Pihlajamäki, Harri; Hietaniemi, Kalevi; Paavola, Mika; Visuri, Tuomo; Mattila, Ville M
2010-10-20
Some have recommended surgical treatment of Grade-III lateral ligament injuries in very active individuals with high functional demands on the ankle. The purpose of this study was to establish whether surgery provides better long-term results than functional treatment for acute ruptures of the lateral ligaments of the ankle. Physically active Finnish men (mean age, 20.4 years) with an acute Grade-III lateral ligament rupture of the ankle were randomly allocated to surgical (n = 25) or functional (n = 26) treatment. Ligament injury was confirmed with stress radiographs. Surgical treatment comprised suture repair of the injured ligament(s) within the first week after injury. A below-the-knee plaster cast was worn for six weeks with full weight-bearing. Functional treatment consisted of the use of an Aircast ankle brace for three weeks. The main outcome measures included final follow-up examinations, calculation of an ankle score, stress radiographs, and magnetic resonance imaging scans. Fifteen (60%) of twenty-five surgically treated patients and eighteen (69%) of twenty-six functionally treated patients returned for long-term follow-up (mean duration, fourteen years). All patients in both groups had recovered their preinjury activity level and reported that they could walk and run normally. The prevalence of reinjury was one of fifteen in the surgical group and seven of eighteen in the functional treatment group (risk difference: 32%; 95% confidence interval: 6% to 58%). The mean ankle score did not differ significantly between the groups (mean difference: 8.3 points; 95% confidence interval: -0.03 to 16.6 points). Stress radiographs revealed no difference between groups with regard to the mean anterior drawer (-1 mm in the surgical group and 0 mm in the functional treatment group; mean difference: 0.7 mm; 95% confidence interval: -1.4 to 2.7 mm) or mean tilt angle (0° in both groups; mean difference: 0.1°; 95% confidence interval: -3.2° to 3.5°). Grade-II osteoarthritis was observed on magnetic resonance images of four of the fifteen surgically treated patients and in none of the eighteen functionally treated patients (risk difference: 27%; 95% confidence interval: 4% to 49%). These findings indicate that, in terms of recovery of the preinjury activity level, the long-term results of surgical treatment of acute lateral ligament rupture of the ankle correspond with those of functional treatment. Although surgery appeared to decrease the prevalence of reinjury of the lateral ligaments, there may be an increased risk for the subsequent development of osteoarthritis.
Electronic gap sensor and method
Williams, R.S.; King, E.L.; Campbell, S.L.
1991-08-06
Disclosed are an apparatus and method for regulating the gap between a casting nozzle and a casting wheel in which the gap between the casting nozzle and the casting wheel is monitored by means of at least one sensing element protruding from the face of the casting nozzle. The sensing element is preferably connected to a voltage source and the casting wheel grounded. When the sensing element contacts the casting wheel, an electric circuit is completed. The completion of the circuit can be registered by an indicator, and the presence or absence of a completed circuit indicates the relative position of the casting nozzle to the casting wheel. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. 5 figures.
Electronic gap sensor and method
Williams, Robert S.; King, Edward L.; Campbell, Steven L.
1991-01-01
An apparatus and method for regulating the gap between a casting nozzle and a casting wheel in which the gap between the casting nozzle and the casting wheel is monitored by means of at least one sensing element protruding from the face of the casting nozzle. The sensing element is preferably connected to a voltage source and the casting wheel grounded. When the sensing element contacts the casting wheel, an electric circuit is completed. The completion of the circuit can be registered by an indicator, and the presence or absence of a completed circuit indicates the relative position of the casting nozzle to the casting wheel. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces.
Method of casting articles of a bulk-solidifying amorphous alloy
Lin, X.; Johnson, W.L.; Peker, A.
1998-08-25
A casting charge of a bulk-solidifying amorphous alloy is cast into a mold from a temperature greater than its crystallized melting temperature, and permitted to solidify to form an article. The oxygen content of the casting charge is limited to an operable level, as excessively high oxygen contents produce premature crystallization during the casting operation. During melting, the casting charge is preferably heated to a temperature above a threshold temperature to eliminate heterogeneous crystallization nucleation sites within the casting charge. The casting charge may be cast from above the threshold temperature, or it may be cooled to the casting temperature of more than the crystallized melting point but not more than the threshold temperature, optionally held at this temperature for a period of time, and thereafter cast. 8 figs.
Method of casting articles of a bulk-solidifying amorphous alloy
Lin, Xianghong; Johnson, William L.; Peker, Atakan
1998-01-01
A casting charge of a bulk-solidifying amorphous alloy is cast into a mold from a temperature greater than its crystallized melting temperature, and permitted to solidify to form an article. The oxygen content of the casting charge is limited to an operable level, as excessively high oxygen contents produce premature crystallization during the casting operation. During melting, the casting charge is preferably heated to a temperature above a threshold temperature to eliminate heterogeneous crystallization nucleation sites within the casting charge. The casting charge may be cast from above the threshold temperature, or it may be cooled to the casting temperature of more than the crystallized melting point but not more than the threshold temperature, optionally held at this temperature for a period of time, and thereafter cast.
Analysis of primary gingivoperiosteoplasty in alveolar cleft repair. Part I: Facial growth.
Henkel, K O; Gundlach, K K
1997-10-01
The primary gingivoperiosteoplasty by Millard consists of presurgical active orthognathic treatment ('Latham device') of the alveolar margins at the age of 3 months and of surgical closure of the alveolar cleft with local gingivoperiosteal flaps at the age of 5 months. The aim of this investigation was to analyse the facial growth following this treatment. The following material was studied: lateral head X-rays and plaster casts from 146 patients with unilateral (UCLP) and bilateral (BCLP) clefts of lip and palate from birth to 16 years of age. Ninety-one of these patients formed the control group, who received neither gingivoperiosteoplasty nor pre-surgical active orthognathic treatment. The same surgeon and orthodontist treated all 146 patients. A three-dimensional growth disturbance after gingivoperiosteoplasty was observed: 42% patients with UCLP and 40% patients with BCLP had an 'open bite' following closure of the alveolar cleft (control group 5%/10%). The length of the upper jaw in patients who underwent gingivoperiosteoplasty was shorter than in the control group. The frequency of posterior cross bite was also higher in the gingivoperiosteoplasty group. These results demonstrate that treatment with a 'Latham device' disturbs facial growth. Therefore, this treatment should be abandoned.
Lamah, L; Diallo, M; Tékpa, J B D; Bah, M L; Keita, K; Sidime, S; Soumah, M T; Diallo, I
2017-06-01
The aim of this study was to analyze the epidemiologic, etiologic, and therapeutic aspects of open wounds of the Achilles tendon managed in the Donka University Hospital. This 3-year prospective included all patients admitted for an Achilles tendon injury. Closed injuries, suppurating wounds, and those that occurred more than 24 hours before admission were excluded. Surgical treatment consisted in debridement and tendon repair, with plaster cast protection for 6 weeks. The study included 36 patients with a mean age of 23.4 years, 29 of whom were male. The primary cause was traffic accidents (n = 21), mainly due to motorcycle taxis (n = 18). The mean follow-up was 9 months. Infection (7 cases) and skin necrosis (5 cases) were the main postoperative complications. The functional result, evaluated by the McComis score, was excellent in 20 cases, good or satisfactory in 10, and poor in 6 cases. Open injuries of the Achilles tendon are common in Guinea-Conakry and mostly due to motorcycle taxis. Outcome of surgical treatment depends on the severity of the injury. Infection and skin necrosis are frequent complications, and their management is challenging in this setting.
Virtual Planning of a Complex Three-Part Bimaxillary Osteotomy
Anghinoni, Marilena Laura
2017-01-01
In maxillofacial surgery, every patient presents special problems requiring careful evaluation. Conventional methods to study the deformities are still reliable, but the advent of tridimensional (3D) imaging, especially computed tomography (CT) scan and laser scanning of casts, created the opportunity to better understanding the skeletal support and the soft tissue structures. Nowadays, virtual technologies are increasingly employed in maxillofacial surgery and demonstrated precision and reliability. However, in complex surgical procedures, these new technologies are still controversial. Especially in the less frequent cases of three-part maxillary surgery, the experience is limited, and scientific literature cannot give a clear support. This paper presents the case of a young patient affected by a complex long face dentofacial deformity treated by a bimaxillary surgery with three-part segmentation of the maxilla. The operator performed the surgical study completely with a virtual workflow. Pre- and postoperative CT scan and optical scanning of plaster models were collected and compared. Every postoperatory maxillary piece was superimposed with the presurgical one, and the differences were examined in a color-coded map. Only mild differences were found near the osteotomy lines, when the bony surface and the teeth demonstrated an excellent coincidence. PMID:29318057
Maffulli, Gayle; Buono, Angelo Del; Richards, Paula; Oliva, Francesco; Maffulli, Nicola
2017-01-01
At present, it is unclear which is the best management for Achilles tendon rupture. We assess the clinical, functional and imaging outcomes of active patients undergoing 3 different types of management for acute subcutaneous rupture of the Achilles tendon, including conservative cast immobilization, traditional open surgery and percutaneous repair. 26 active patients were managed for a rupture of the Achilles Tendon from January 2007 to March 2008. Anthropometric measurements, Functional assessment, Isometric strength, Ultrasonographic assessment, Patient satisfaction, Working life, Physical activity, Functional score and Complications were recorded retrospectively. All 23 (21 men, 2 women) patients were reviewed at a minimum follow-up of 24 months (average 25.7, range 24 to 32 months, SD: 6.3) from the index injury. Thermann scores and patient satisfaction were significantly higher following surgery than conservative management with no significance between open and minimally invasive operated patients. Sensitive disturbances occur in up to 12% of open repairs and 1.8% of patients managed nonsurgically. Clinical and functional outcomes following surgical repair, percutaneous and open, of the Achilles tendon are significantly improved than following conservative management. Level III.
Extrahepatic arteries of the human liver - anatomical variants and surgical relevancies.
Németh, Károly; Deshpande, Rahul; Máthé, Zoltán; Szuák, András; Kiss, Mátyás; Korom, Csaba; Nemeskéri, Ágnes; Kóbori, László
2015-10-01
The purpose of our study was to investigate the anatomical variations of the extrahepatic arterial structures of the liver with particular attention to rare variations and their potential impact on liver surgery. A total of 50 human abdominal organ complexes were used to prepare corrosion casts. A multicomponent resin mixture was injected into the abdominal aorta. The portal vein was injected with a different colored resin in 16 cases. Digestion of soft tissues was achieved using cc. KOH solution at 60-65 °C. Extrahepatic arterial variations were classified according to Michels. All specimens underwent 3D volumetric CT reconstruction. Normal anatomy was seen in 42% of cases, and variants were seen in the other 58%. No Michels type VI or X variations were present; however, in 18% of cases the extrahepatic arterial anatomy did not fit into Michels' classification. We report four new extrahepatic arterial variations. In contrast to the available data, normal anatomy was found much less frequently, whereas the prevalence of unclassified arterial variations was higher. We detected four previously unknown variations. Our data may contribute to the reduction of complications during surgical and radiological interventions in the upper abdomen. © 2015 Steunstichting ESOT.
How to Avoid Cast Saw Complications.
Halanski, Matthew A
2016-06-01
As casts are routinely used in pediatric orthopaedics, casts saws are commonly used to remove such casts. Despite being a viewed as the "conservative" and therefore often assumed safest treatment modality, complications associated with the use of casts and cast saws occur. In this manuscript, we review the risk factors associated with cast saw injuries. Cast saw injuries are thermal or abrasive (or both) in nature. Thermal risk factors include: cast saw specifications (including a lack of attached vacuum), use of a dull blade, cutting in a concavity, too thin padding, and overly thick casting materials. Risk factors associated with abrasive injuries include: sharp blades, thin padding, and cutting over boney prominences. Because nearly all clinicians contact the skin with the blade during cast removal, appropriate "in-out technique" is critical. Such technique prevents a hot blade from remaining in contact with the skin for any significant time, diminishing the risk of burn. Similarly, using such technique prevents "dragging the blade" that may pull the skin taught, cutting it. It may be useful to teach proper technique as perforating a cast rather than cutting a cast.
[Manufacture and clinical application of 215 IPS-Empress casting ceramic restorations].
Zhao, Na; Zhou, Jian
2008-08-01
To explore the manufacture and clinical application of IPS-Empress casting ceramic restorations. The problems in manufacture and clinical operation of 215 casting ceramic restorations were analyzed. In 215 casting ceramic restorations, 12 (5.58%) casting ceramic restorations were affected by clinical design or application, 15 (6.98%) casting ceramic restorations were affected by some manufacture problems, and 14 (6.51%) casting ceramic restorations were affected by clinical try-in. Through 2-3 years' follow-up, the achievement ratio of 215 IPS-Empress casting ceramic restorations was 94.88%, and 11 casting ceramic restorations were affected by some problems. Beauty and simultaneous enamel wear are the characteristics of casting ceramic restorations. But because of its brittle, the indications should be strictly selected.
Thompson, Geoffrey A; Luo, Qing; Hefti, Arthur
2013-12-01
Previous studies have shown casting methodology to influence the as-cast properties of dental casting alloys. It is important to consider clinically important mechanical properties so that the influence of casting can be clarified. The purpose of this study was to evaluate how torch/centrifugal and inductively cast and vacuum-pressure casting machines may affect the castability, microhardness, chemical composition, and microstructure of 2 high noble, 1 noble, and 1 base metal dental casting alloys. Two commonly used methods for casting were selected for comparison: torch/centrifugal casting and inductively heated/ vacuum-pressure casting. One hundred and twenty castability patterns were fabricated and divided into 8 groups. Four groups were torch/centrifugally cast in Olympia (O), Jelenko O (JO), Genesis II (G), and Liberty (L) alloys. Similarly, 4 groups were cast in O, JO, G, and L by an inductively induction/vacuum-pressure casting machine. Each specimen was evaluated for casting completeness to determine a castability value, while porosity was determined by standard x-ray techniques. Each group was metallographically prepared for further evaluation that included chemical composition, Vickers microhardness, and grain analysis of microstructure. Two-way ANOVA was used to determine significant differences among the main effects. Statistically significant effects were examined further with the Tukey HSD procedure for multiple comparisons. Data obtained from the castability experiments were non-normal and the variances were unequal. They were analyzed statistically with the Kruskal-Wallis rank sum test. Significant results were further investigated statistically with the Steel-Dwass method for multiple comparisons (α=.05). The alloy type had a significant effect on surface microhardness (P<.001). In contrast, the technique used for casting did not affect the microhardness of the test specimen (P=.465). Similarly, the interaction between the alloy and casting technique was not significant (P=.119). A high level of castability (98.5% on average) was achieved overall. The frequency of casting failures as a function of alloy type and casting method was determined. Failure was defined as a castability index score of <100%. Three of 28 possible comparisons between alloy and casting combinations were statistically significant. The results suggested that casting technique affects the castability index of alloys. Radiographic analysis detected large porosities in regions near the edge of the castability pattern and infrequently adjacent to noncast segments. All castings acquired traces of elements found in the casting crucibles. The grain size for each dental casting alloy was generally finer for specimens produced by the induction/vacuum-pressure method. The difference was substantial for JO and L. This study demonstrated a relation between casting techniques and some physical properties of metal ceramic casting alloys. Copyright © 2013 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Salvaged castings and methods of salvaging castings with defective cast cooling bumps
Johnson, Robert Alan; Schaeffer, Jon Conrad; Lee, Ching-Pang; Abuaf, Nesim; Hasz, Wayne Charles
2002-01-01
Castings for gas turbine parts exposed on one side to a high-temperature fluid medium have cast-in bumps on an opposite cooling surface side to enhance heat transfer. Areas on the cooling surface having defectively cast bumps, i.e., missing or partially formed bumps during casting, are coated with a braze alloy and cooling enhancement material to salvage the part.
Ye, Hao; Luo, Heng; Ng, Hui Wen; Meehan, Joe; Ge, Weigong; Tong, Weida; Hong, Huixiao
2016-01-01
ToxCast data have been used to develop models for predicting in vivo toxicity. To predict the in vivo toxicity of a new chemical using a ToxCast data based model, its ToxCast bioactivity data are needed but not normally available. The capability of predicting ToxCast bioactivity data is necessary to fully utilize ToxCast data in the risk assessment of chemicals. We aimed to understand and elucidate the relationships between the chemicals and bioactivity data of the assays in ToxCast and to develop a network analysis based method for predicting ToxCast bioactivity data. We conducted modularity analysis on a quantitative network constructed from ToxCast data to explore the relationships between the assays and chemicals. We further developed Nebula (neighbor-edges based and unbiased leverage algorithm) for predicting ToxCast bioactivity data. Modularity analysis on the network constructed from ToxCast data yielded seven modules. Assays and chemicals in the seven modules were distinct. Leave-one-out cross-validation yielded a Q(2) of 0.5416, indicating ToxCast bioactivity data can be predicted by Nebula. Prediction domain analysis showed some types of ToxCast assay data could be more reliably predicted by Nebula than others. Network analysis is a promising approach to understand ToxCast data. Nebula is an effective algorithm for predicting ToxCast bioactivity data, helping fully utilize ToxCast data in the risk assessment of chemicals. Published by Elsevier Ltd.
Dimensional control of die castings
NASA Astrophysics Data System (ADS)
Karve, Aniruddha Ajit
The demand for net shape die castings, which require little or no machining, is steadily increasing. Stringent customer requirements are forcing die casters to deliver high quality castings in increasingly short lead times. Dimensional conformance to customer specifications is an inherent part of die casting quality. The dimensional attributes of a die casting are essentially dependent upon many factors--the quality of the die and the degree of control over the process variables being the two major sources of dimensional error in die castings. This study focused on investigating the nature and the causes of dimensional error in die castings. The two major components of dimensional error i.e., dimensional variability and die allowance were studied. The major effort of this study was to qualitatively and quantitatively study the effects of casting geometry and process variables on die casting dimensional variability and die allowance. This was accomplished by detailed dimensional data collection at production die casting sites. Robust feature characterization schemes were developed to describe complex casting geometry in quantitative terms. Empirical modeling was utilized to quantify the effects of the casting variables on dimensional variability and die allowance for die casting features. A number of casting geometry and process variables were found to affect dimensional variability in die castings. The dimensional variability was evaluated by comparisons with current published dimensional tolerance standards. The casting geometry was found to play a significant role in influencing the die allowance of the features measured. The predictive models developed for dimensional variability and die allowance were evaluated to test their effectiveness. Finally, the relative impact of all the components of dimensional error in die castings was put into perspective, and general guidelines for effective dimensional control in the die casting plant were laid out. The results of this study will contribute to enhancement of dimensional quality and lead time compression in the die casting industry, thus making it competitive with other net shape manufacturing processes.
Lower limb intracast pressures generated by different types of immobilisation casts.
Chaudhury, Salma; Hazlerigg, Alexandra; Vusirikala, Anuhya; Nguyen, Joseph; Matthews, Stuart
2017-02-18
To determine if complete, split casts and backslabs [plaster of Paris (POP) and fiberglass] generate different intracast pressures and pain. Increased swelling within casts was modeled by a closed water system attached to an expandable bag placed directly under different types of casts applied to a healthy lower limb. Complete fiberglass and POP casts, split casts and backslabs were applied. Twenty-five milliliter aliquots of saline were injected into the system and the generated intracast pressures were measured using a sphygmomanometer. The subject was blinded to the pressure scores to avoid bias. All casts were applied to the same right limb on the same subject to avoid the effects of variations in anatomy or physiology on intracast pressures. Pain levels were evaluated using the Visual Analogue Score after each sequential saline injection. Each type of cast was reapplied four times and the measurements were repeated on four separate occasions. Sample sizes were determined by a pre-study 90% power calculation to detect a 20% difference in intracast pressures between cast groups. A significant difference between the various types of casts was noted when the saline volume was greater than 100 mL ( P = 0.009). The greatest intracast pressure was generated by complete fiberglass casts, which were significantly higher than complete POP casts or backslabs ( P = 0.018 and P = 0.008 respectively) at intracast saline volumes of 100 mL and higher. Backslabs produced a significantly lower intracast pressure compared to complete POP only once the saline volume within casts exceeded 225 mL ( P = 0.009). Intracast pressures were significantly lower in split casts ( P = 0.003). Split POP and fiberglass casts produced the lowest intracast pressures, even compared to backslabs ( P = 0.009). Complete fiberglass casts generated the highest pain levels at manometer pressures of 75 mmHg and greater ( P = 0.001). Split fiberglass casts had significantly reduced pain levels ( P = 0.001). In contrast, a split complete POP cast did not produce significantly reduced pain levels at pressures between 25-150 mmHg. There was no difference in pain generated by complete POP and backslabs at manometer pressures of 200 mmHg and lower. Fibreglass casts generate significantly higher intracast pressures and pain than POP casts. Split casts cause lower intracast pressures regardless of material, than complete casts and backslabs.
Riser Feeding Evaluation Method for Metal Castings Using Numerical Analysis
NASA Astrophysics Data System (ADS)
Ahmad, Nadiah
One of the design aspects that continues to create a challenge for casting designers is the optimum design of casting feeders (risers). As liquid metal solidifies, the metal shrinks and forms cavities inside the casting. In order to avoid shrinkage cavities, risers are added to the casting shape to supply additional molten metal when shrinkage occurs during solidification. The shrinkage cavities in the casting are compensated by controlling the cooling rate to promote directional solidification. This control can be achieved by designing the casting such that the cooling begins at the sections that are farthest away from the risers and ends at the risers. Therefore, the risers will solidify last and feed the casting with the molten metal. As a result, the shrinkage cavities formed during solidification are in the risers which are later removed from the casting. Since casting designers have to usually go through iterative processes of validating the casting designs which are very costly due to expensive simulation processes or manual trials and errors on actual casting processes, this study investigates more efficient methods that will help casting designers utilize their casting experiences systematically to develop good initial casting designs. The objective is to reduce the casting design method iterations; therefore, reducing the cost involved in that design processes. The aim of this research aims at finding a method that can help casting designers design effective risers used in sand casting process of aluminum-silicon alloys by utilizing the analysis of solidification simulation. The analysis focuses on studying the significance of pressure distribution of the liquid metal at the early stage of casting solidification, when heat transfer and convective fluid flow are taken into account in the solidification simulation. The mathematical model of casting solidification was solved using the finite volume method (FVM). This study focuses to improve our understanding of the feeding behavior in aluminum-silicon alloys and the effective feeding by considering the pressure gradient distribution of the molten metal at casting dendrite coherency point. For this study, we will identify the relationship between feeding efficiency, shrinkage behavior and how the change in riser size affects the pressure gradient in the casting. This understanding will be used to help in the design of effective risers.
The Role of Indian Caste Identity and Caste Inconsistent Norms on Status Representation
Sankaran, Sindhuja; Sekerdej, Maciek; von Hecker, Ulrich
2017-01-01
The Indian caste system is a complex social structure wherein social roles like one’s profession became ‘hereditary,’ resulting in restricted social mobility and fixed status hierarchies. Furthermore, we argue that the inherent property of caste heightens group identification with one’s caste. Highly identified group members would protect the identity of the group in situations when group norms are violated. In this paper, we were interested in examining the consequence of caste norm violation and how an individual’s status is mentally represented. High caste norms are associated with moral values while the lower caste norms are associated with immorality. We predicted a ‘black sheep effect,’ that is, when high caste individuals’ group identity (caste norm violation condition) is threatened their salient high caste identity would increase, thereby resulting in devaluing the status of their fellow in-group member if the latter is perceived as perpetrator. We presented participants with a social conflict situation of a victim and a perpetrator that is ‘Caste norm consistent’ (Lower caste individual as a perpetrator and higher caste individual as a victim) and vice versa ‘Caste norm inconsistent’ condition (higher caste individual as perpetrator and lower caste individual as a victim). Then, participants had to choose from nine pictorial depictions representing the protagonists in the story on a vertical line, with varying degrees of status distance. Results showed evidence for the black sheep effect and, furthermore, revealed that no other identity (religious, national, and regional) resulted in devaluing the status of fellow in-group member. These results help us understand the ‘black sheep’ effect in the context of moral norms and status representation and are discussed in the framework of the Indian society. PMID:28408896
The Role of Indian Caste Identity and Caste Inconsistent Norms on Status Representation.
Sankaran, Sindhuja; Sekerdej, Maciek; von Hecker, Ulrich
2017-01-01
The Indian caste system is a complex social structure wherein social roles like one's profession became 'hereditary,' resulting in restricted social mobility and fixed status hierarchies. Furthermore, we argue that the inherent property of caste heightens group identification with one's caste. Highly identified group members would protect the identity of the group in situations when group norms are violated. In this paper, we were interested in examining the consequence of caste norm violation and how an individual's status is mentally represented. High caste norms are associated with moral values while the lower caste norms are associated with immorality. We predicted a 'black sheep effect,' that is, when high caste individuals' group identity (caste norm violation condition) is threatened their salient high caste identity would increase, thereby resulting in devaluing the status of their fellow in-group member if the latter is perceived as perpetrator. We presented participants with a social conflict situation of a victim and a perpetrator that is ' Caste norm consistent' (Lower caste individual as a perpetrator and higher caste individual as a victim) and vice versa 'Caste norm inconsistent' condition (higher caste individual as perpetrator and lower caste individual as a victim). Then, participants had to choose from nine pictorial depictions representing the protagonists in the story on a vertical line, with varying degrees of status distance. Results showed evidence for the black sheep effect and, furthermore, revealed that no other identity (religious, national, and regional) resulted in devaluing the status of fellow in-group member. These results help us understand the 'black sheep' effect in the context of moral norms and status representation and are discussed in the framework of the Indian society.
Rehabilitation for ankle fractures in adults.
Lin, Chung-Wei Christine; Donkers, Nicole A J; Refshauge, Kathryn M; Beckenkamp, Paula R; Khera, Kriti; Moseley, Anne M
2012-11-14
Rehabilitation after ankle fracture can begin soon after the fracture has been treated, either surgically or non-surgically, by the use of different types of immobilisation that allow early commencement of weight-bearing or exercise. Alternatively, rehabilitation, including the use of physical or manual therapies, may start following the period of immobilisation. This is an update of a Cochrane review first published in 2008. To assess the effects of rehabilitation interventions following conservative or surgical treatment of ankle fractures in adults. We searched the Specialised Registers of the Cochrane Bone, Joint and Muscle Trauma Group and the Cochrane Rehabilitation and Related Therapies Field, CENTRAL via The Cochrane Library (2011 Issue 7), MEDLINE via PubMed, EMBASE, CINAHL, PEDro, AMED, SPORTDiscus and clinical trials registers up to July 2011. In addition, we searched reference lists of included studies and relevant systematic reviews. Randomised and quasi-randomised controlled trials with adults undergoing any interventions for rehabilitation after ankle fracture were considered. The primary outcome was activity limitation. Secondary outcomes included quality of life, patient satisfaction, impairments and adverse events. Two review authors independently screened search results, assessed risk of bias and extracted data. Risk ratios and 95% confidence intervals (95% CIs) were calculated for dichotomous variables, and mean differences or standardised mean differences and 95% CIs were calculated for continuous variables. End of treatment and end of follow-up data were presented separately. For end of follow-up data, short term follow-up was defined as up to three months after randomisation, and long-term follow-up as greater than six months after randomisation. Meta-analysis was performed where appropriate. Thirty-eight studies with a total of 1896 participants were included. Only one study was judged at low risk of bias. Eight studies were judged at high risk of selection bias because of lack of allocation concealment and over half the of the studies were at high risk of selective reporting bias.Three small studies investigated rehabilitation interventions during the immobilisation period after conservative orthopaedic management. There was limited evidence from two studies (106 participants in total) of short-term benefit of using an air-stirrup versus an orthosis or a walking cast. One study (12 participants) found 12 weeks of hypnosis did not reduce activity or improve other outcomes.Thirty studies investigated rehabilitation interventions during the immobilisation period after surgical fixation. In 10 studies, the use of a removable type of immobilisation combined with exercise was compared with cast immobilisation alone. Using a removable type of immobilisation to enable controlled exercise significantly reduced activity limitation in five of the eight studies reporting this outcome, reduced pain (number of participants with pain at the long term follow-up: 10/35 versus 25/34; risk ratio (RR) 0.39, 95% confidence interval (CI) 0.22 to 0.68; 2 studies) and improved ankle dorsiflexion range of motion. However, it also led to a higher rate of mainly minor adverse events (49/201 versus 20/197; RR 2.30, 95% CI 1.49 to 3.56; 7 studies).During the immobilisation period after surgical fixation, commencing weight-bearing made a small improvement in ankle dorsiflexion range of motion (mean difference in the difference in range of motion compared with the non-fractured side at the long term follow-up 6.17%, 95% CI 0.14 to 12.20; 2 studies). Evidence from one small but potentially biased study (60 participants) showed that neurostimulation, an electrotherapy modality, may be beneficial in the short-term. There was little and inconclusive evidence on what type of support or immobilisation was the best. One study found no immobilisation improved ankle dorsiflexion and plantarflexion range of motion compared with cast immobilisation, but another showed using a backslab improved ankle dorsiflexion range of motion compared with using a bandage.Five studies investigated different rehabilitation interventions following the immobilisation period after either conservative or surgical orthopaedic management. There was no evidence of effect for stretching or manual therapy in addition to exercise, or exercise compared with usual care. One small study (14 participants) at a high risk of bias found reduced ankle swelling after non-thermal compared with thermal pulsed shortwave diathermy. There is limited evidence supporting early commencement of weight-bearing and the use of a removable type of immobilisation to allow exercise during the immobilisation period after surgical fixation. Because of the potential increased risk of adverse events, the patient's ability to comply with the use of a removable type of immobilisation to enable controlled exercise is essential. There is little evidence for rehabilitation interventions during the immobilisation period after conservative orthopaedic management and no evidence for stretching, manual therapy or exercise compared to usual care following the immobilisation period. Small, single studies showed that some electrotherapy modalities may be beneficial. More clinical trials that are well-designed and adequately-powered are required to strengthen current evidence.
Casting fine grained, fully dense, strong inorganic materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Sam W.; Spencer, Larry S.; Phillips, Michael R.
2015-11-24
Methods and apparatuses for casting inorganic materials are provided. The inorganic materials include metals, metal alloys, metal hydrides and other materials. Thermal control zones may be established to control the propagation of a freeze front through the casting. Agitation from a mechanical blade or ultrasonic energy may be used to reduce porosity and shrinkage in the casting. After solidification of the casting, the casting apparatus may be used to anneal the cast part.
Liang, Qin-ye; Wu, Xia-yi; Lin, Xue-feng
2012-04-01
To investigate the surface roughness property of the titanium castings cast in a new investment for titanium casting. Six wax patterns (20 mm × 20 mm × 0.5 mm) were invested using two investments: three in a new titanium investment material and three in the control material (Rematitan Plus). Six titanium specimens were obtained by conventional casting. After casting, surface roughness of the specimens were evaluated with a surface profilometer. The surface roughness of the specimens cast in new titanium investment material was (1.72 ± 0.08) µm, which was much smaller than that from Rematitan Plus [(1.91 ± 0.15) µm, P < 0.05]. The surfaces of titanium cast using these two investment materials are both smooth enough to fulfill the demand of the titanium precision-casting for prosthodontic clinical use.
Alex, Deepa; Shetty, Y Bharath; Miranda, Glynis Anita; Prabhu, M Bharath; Karkera, Reshma
2015-01-01
Conventional investing and casting techniques are time-consuming and usually requires 2-4 h for completion. Accelerated nonstandard, casting techniques have been reported to achieve similar quality results in significantly less time, namely, in 30-40 min. During casting, it is essential to achieve compensation for the shrinkage of solidifying alloy by investment expansion. The metal casting ring restricts the thermal expansion of investment because the thermal expansion of the ring is lesser than that of the investment. The use of casting ring was challenged with the introduction of the ringless technique. A total of 40 test samples of nickel chromium (Ni-Cr) cast copings were obtained from the patterns fabricated using inlay casting wax. The 20 wax patterns were invested using metal ring and 20 wax patterns were invested using the ringless investment system. Of both the groups, 10 samples underwent conventional casting, and the other 10 underwent accelerated casting. The patterns were casted using the induction casting technique. All the test samples of cast copings were evaluated for vertical marginal gaps at four points on the die employing a stereo optical microscope. The vertical marginal discrepancy data obtained were tabulated. Mean and standard deviations were obtained. Vertical discrepancies were analyzed using analysis of variance and Tukey honestly significantly different. The data obtained were found to be very highly significant (P < 0.001). Mean vertical gap was the maximum for Group II (53.64 μm) followed by Group IV (47.62 μm), Group I (44.83 μm) and Group III (35.35 μm). The Ni-Cr cast copings fabricated with the conventional casting using ringless investment system showed significantly better marginal fit than that of cast copings fabricated from conventional and accelerated casting with metal ring investment and accelerated casting using ringless investment since those copings had shown the least vertical marginal discrepancies among the four methods evaluated in this study.
Braithwaite, Irene; Mackintosh, Stephen; Buchanan, Samantha; Schwarzenlander, Kerstin; De Ruyter, Bernadette
2017-02-01
We investigated popliteal venous haemodynamics of the VenaJet Jet Impulse Technology system within a below-knee fibreglass cast. Randomized controlled trial. Twenty-four healthy participants aged 18-54 had both feet placed within the Jet Impulse Technology system and were randomised for one or other leg to be within a below-knee fibreglass cast. Pacific Radiology, Lower Hutt, Wellington. The primary outcome variable was peak systolic velocity (cm/s) compared between legs with and without the cast at 60 min (after 10 min Jet Impulse Technology activation), using a mixed linear model and a non-inferiority bound of 4.8 cm/s. Secondary outcome variables were the difference in peak systolic velocity between the casted limb and the non-casted limb at baseline and 40 min after casting, and the difference in mean flow velocity (cm/s), vein diameter (mm), and total volume flow (L/min) between the casted limb and the non-casted limb at baseline, 40 and 60 min. The mean (standard deviation) peak systolic velocity was 4.6(1.5), 4.8(1.1), 28.8(16.1), and 4.3(1.2), 4.8(1.4) and 29.3(19.0) cm/s at baseline, 40 and 60 min in the casted and non-casted leg, respectively. The difference (95% confidence interval) between cast and no-cast at 60 min was -0.8 (-6.5 to 4.9) cm/s, P = 0.78. The peak systolic velocity, flow velocity and total volume flow at 40 min were not statistically significantly different from baseline for both casted and non-casted limb. In healthy volunteers, the popliteal venous haemodynamics of the Jet Impulse Technology system was similar between the legs with and without a below-knee fibreglass cast. In-cast Jet Impulse Technology may provide a non-pharmacological option for venous thromboembolism prophylaxis for lower-limb cast-immobility.
Schoenecker, P L
1986-09-01
Legg-Calvé-Perthes disease, or osteochondrosis of the femoral head, occurs predominantly in boys 4 to 7 years of age. The disease progresses through synovitis, necrosis, fragmentation, and a residual stage. Outcome can be affected by age at disease onset, the extent of femoral head involvement as determined by x-ray, and the degree to which normal range of motion is maintained. The goal of treatment is to minimize residual deformity of the femoral head and acetabulum. This is accomplished by containing the femoral head well within the acetabulum and maintaining range of motion while the disease process runs its course. In extremely young patients, containment is often achieved during normal daily living activities. Containment treatment methods include abduction casting or orthosis; surgical containment can be accomplished by femoral or innominate osteotomy.
Wasiak, K; Paczkowski, P M; Garlicki, J M
2006-01-01
The authors present their experience in the treatment of chronic lower limb ischaemia resulting from atherosclerosis by below knee amputation according to Ghormley's technique, with the immediate application of a semi-rigid plaster cast and early rehabilitation. From a group of 664 patients requiring major amputations, 61 patients (52 men) aged 64 +/- 11 fulfilled the criteria for unilateral below-knee amputation for critical limb ischaemia for atherosclerosis consequences. Peri-operative (30-days) mortality was of 3.28%. Stump healing was very good or good (no need for further surgery) in over 2/3 of patients, but in 20% the need for above-knee amputation developed. Postoperative knee contracture (defined as 15 degrees or more limitation to the movement range) was observed in 11.5% of patients.
1988-06-30
casting. 68 Figure 1-9: Line printer representation of roll solidification. 69 Figure I1-1: Test casting model. 76 Figure 11-2: Division of test casting...writing new casting analysis and design routines. The new routines would take advantage of advanced criteria for predicting casting soundness and cast...properties and technical advances in computer hardware and software. 11 2. CONCLUSIONS UPCAST, a comprehensive software package, has been developed for
Method and apparatus for in-situ drying investigation and optimization of slurry drying methodology
Armstrong, Beth L.; Daniel, Claus; Howe, Jane Y.; Kiggans, Jr, James O.; Sabau, Adrian S.; Wood, III, David L.; Kalnaus, Sergiy
2016-05-10
A method of drying casted slurries that includes calculating drying conditions from an experimental model for a cast slurry and forming a cast film. An infrared heating probe is positioned on one side of the casted slurry and a thermal probe is positioned on an opposing side of the casted slurry. The infrared heating probe may control the temperature of the casted slurry during drying. The casted slurry may be observed with an optical microscope, while applying the drying conditions from the experimental model. Observing the casted slurry includes detecting the incidence of micro-structural changes in the casted slurry during drying to determine if the drying conditions from the experimental model are optimal.
Watkins, WS; Thara, R; Mowry, BJ; Zhang, Y; Witherspoon, DJ; Tolpinrud, W; Bamshad, MJ; Tirupati, S; Padmavati, R; Smith, H; Nancarrow, D; Filippich, C; Jorde, LB
2008-01-01
Background Major population movements, social structure, and caste endogamy have influenced the genetic structure of Indian populations. An understanding of these influences is increasingly important as gene mapping and case-control studies are initiated in South Indian populations. Results We report new data on 155 individuals from four Tamil caste populations of South India and perform comparative analyses with caste populations from the neighboring state of Andhra Pradesh. Genetic differentiation among Tamil castes is low (RST = 0.96% for 45 autosomal short tandem repeat (STR) markers), reflecting a largely common origin. Nonetheless, caste- and continent-specific patterns are evident. For 32 lineage-defining Y-chromosome SNPs, Tamil castes show higher affinity to Europeans than to eastern Asians, and genetic distance estimates to the Europeans are ordered by caste rank. For 32 lineage-defining mitochondrial SNPs and hypervariable sequence (HVS) 1, Tamil castes have higher affinity to eastern Asians than to Europeans. For 45 autosomal STRs, upper and middle rank castes show higher affinity to Europeans than do lower rank castes from either Tamil Nadu or Andhra Pradesh. Local between-caste variation (Tamil Nadu RST = 0.96%, Andhra Pradesh RST = 0.77%) exceeds the estimate of variation between these geographically separated groups (RST = 0.12%). Low, but statistically significant, correlations between caste rank distance and genetic distance are demonstrated for Tamil castes using Y-chromosome, mtDNA, and autosomal data. Conclusion Genetic data from Y-chromosome, mtDNA, and autosomal STRs are in accord with historical accounts of northwest to southeast population movements in India. The influence of ancient and historical population movements and caste social structure can be detected and replicated in South Indian caste populations from two different geographic regions. PMID:19077280
Dykes, Charles D.; Daniel, Sabah S.; Wood, J. F. Barry
1990-02-20
In continuously casting molten metal into cast product by a twin-belt machine, it is desirable to achieve dramatic increases in speed (linear feet per minute) at which cast product exits the machine, particularly in installations where steel cast product is intended to feed a downstream regular rolling mill (as distinct from a planetary mill) operating in tandem with the twin-belt caster. Such high-speed casting produces product with a relatively thin shell and molten interior, and the shell tends to bulge outwardly due to metallostatic head pressure of the molten center. A number of cooperative features enable high-speed, twin-belt casting: (1) Each casting belt is slidably supported adjacent to the caster exit pulley for bulge control and enhanced cooling of cast product. (2) Lateral skew steering of each belt provides an effective increase in moving mold length plus a continuity of heat transfer not obtained with prior art belt steering apparatus. (3) The exiting slab is contained and supported downstream from the casting machine to prevent bulging of the shell of the cast product, and (4) spray cooling is incorporated in the exit containment apparatus for secondary cooling of cast product.
Kalavathi, M; Sachin, Bhuvana; Prasanna, B G; Shreeharsha, T V; Praveen, B; Ragher, Mallikarjuna
2016-02-01
The thermal expansion of the investment can be restricted by the metal casting ring because the thermal expansion of the ring is less than that of the investment. The ringless casting procedure is in use in clinical dentistry, though there is little scientific data to support its use in fixed partial dentures. In this study, marginal discrepancy of castings produced with the ringless casting technique and the conventional technique using the metal rings were compared. A total of 30 wax patterns were fabricated directly on a metal die. Optical stereomicroscope was used to measure the marginal discrepancy between the metal die and wax patterns. A total of 15 castings were invested using Bellavest T phosphate-bonded investment with the ringless technique and 15 were invested with the same investment with a metal ring; 30 castings were produced using a nickel-chromium ceramo-metal alloy. The internal surface of the castings was not modified and seated with finger pressure. The vertical marginal discrepancy was measured using an optical stereomicroscope at a magnification of 100x. The data obtained were statistically analyzed using students t-test (paired t-test and unpaired t-test). The castings of the ringless technique provided less vertical marginal discrepancy (240.56 ± 45.81 μ) than the castings produced with the conventional metal ring technique (281.98± 53.05 μ). The difference was statistically significant. The ringless casting technique had produced better marginal accuracy compared with conventional casting technique. Ringless casting system can be used routinely for clinical purpose.
46 CFR 56.60-10 - Cast iron and malleable iron.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Cast iron and malleable iron. 56.60-10 Section 56.60-10... APPURTENANCES Materials § 56.60-10 Cast iron and malleable iron. (a) The low ductility of cast iron and... avoided. Cast iron and malleable iron components shall not be used at temperatures above 450 °F. Cast iron...
Mahan, Susan T; Harris, Marie S; Lierhaus, Anneliese M; Miller, Patricia E; DiFazio, Rachel L
Noise reduction headphones decrease the sound during cast removal. Their effectiveness in decreasing anxiety has not been studied. Compare pediatric patients' anxiety levels during cast removal with and without utilization of noise reduction headphones combined with use of a personal electronic device. Quality improvement project. Patients randomly assigned to noise reduction headphone group or standard care group during cast removal. Faces, Legs, Activity, Cry, and Consolability Scale and heart rate were evaluated prior to, during, and after cast removal. Data were compared across groups. Fifty patients were included; 25 per group. No difference detected between the 2 groups in Faces, Legs, Activity, Cry, and Consolability Scale score prior to (p = .05) or after cast removal (p = .30). During cast removal, the headphone group had lower FLACC Scale scores (p = .03). Baseline heart rate was lower in the headphone group prior to (p = .02) and after (p = .005) cast removal with no difference during cast removal (p = .24). Utilizing noise reduction headphones and a personal electronic device during the cast removal process decreases patient anxiety.
[Variables effecting casting accuracy of quick heating casting investments].
Takahashi, H; Nakamura, H; Iwasaki, N; Morita, N; Habu, N; Nishimura, F
1994-06-01
Recently, several new products of investments for "quick heating" have been put on the Japanese market. The total casting procedure time for this quick heating method involves only one hour; 30-minutes waiting after the start of mixing before placing the mold directly into the 700 degrees C furnace and 30-minutes heating in the furnace. The purpose of this study was to evaluate two variables effecting casting accuracy using these new investments. The effect of thickness of the casting liner inside the casting ring and the effect of waiting time before placing the mold into the 700 degrees C furnace were evaluated. A stainless-steel die with a convergence angle of 8 degrees was employed. Marginal discrepancies of the crown between the wax patterns and castings were measured. The size of the cast crown became larger when the thickness of the ring liner was thick and when the waiting time before placing the mold into the furnace was long. These results suggest that these new investments have the advantage of providing sound castings using short-time casting procedures. However, it is necessary to pay careful attention to the casting conditions for obtaining reproducible castings.
Meier Bürgisser, Gabriella; Calcagni, Maurizio; Bachmann, Elias; Fessel, Gion; Snedeker, Jess G.; Giovanoli, Pietro
2016-01-01
ABSTRACT After tendon rupture repair, two main problems may occur: re-rupture and adhesion formation. Suitable non-murine animal models are needed to study the healing tendon in terms of biomechanical properties and extent of adhesion formation. In this study 24 New Zealand White rabbits received a full transection of the Achilles tendon 2 cm above the calcaneus, sutured with a 4-strand Becker suture. Post-surgical analysis was performed at 3, 6 and 12 weeks. In the 6-week group, animals received a cast either in a 180 deg stretched position during 6 weeks (adhesion provoking immobilization), or were re-casted with a 150 deg position after 3 weeks (adhesion inhibiting immobilization), while in the other groups (3 and 12 weeks) a 180 deg position cast was applied for 3 weeks. Adhesion extent was analyzed by histology and ultrasound. Histopathological scoring was performed according to a method by Stoll et al. (2011), and the main biomechanical properties were assessed. Histopathological scores increased as a function of time, but did not reach values of healthy tendons after 12 weeks (only around 15 out of 20 points). Adhesion provoking immobilization led to an adhesion extent of 82.7±9.7%, while adhesion inhibiting immobilization led to 31.9±9.8% after 6 weeks. Biomechanical properties increased over time, however, they did not reach full strength nor elastic modulus at 12 weeks post-operation. Furthermore, the rabbit Achilles tendon model can be modulated in terms of adhesion formation to the surrounding tissue. It clearly shows the different healing stages in terms of histopathology and offers a suitable model regarding biomechanics because it exhibits similar biomechanics as the human flexor tendons of the hand. PMID:27635037
Distal limb cast sores in horses: risk factors and early detection using thermography.
Levet, T; Martens, A; Devisscher, L; Duchateau, L; Bogaert, L; Vlaminck, L
2009-01-01
There is a lack of evidence-based data on the prevalence, outcome and risk factors of distal limb cast sores, and no objective tool has been described for the early detection of cast sores. To investigate the prevalence, location, outcome and risk factors of cast sores after application of a distal limb cast and to determine whether static thermography of the cast is a valuable tool for the assessment of sores. A prospective study was conducted on horses treated with a distal limb cast. At each cast removal, cast sores were graded as superficial sores (SS), deep dermal sores (DS) or full thickness skin ulcerations (FS). In several cases, a thermographic evaluation of the cast was performed immediately prior to removal and differences in temperature (AT) between the coolest point of the cast and 2 cast regions predisposed for sore development (dorsoproximal mc/mtIII and palmar/plantar fetlock) were calculated. Mean +/- s.d. total casting time of 70 horses was 31 +/- 18 days. Overall, 57 legs (81%) developed at least SS. Twenty-four legs (34%) ultimately developed DS and one horse had an FS. Multivariable analysis showed that the severity of sores was positively associated with increasing age (OR: 1.111, P = 0.028), a normal (vs. swollen) limb (OR: 3387, P = 0.023) and an increase in total casting time (OR per week: 1.363, P = 0.002). The thermographic evaluation (35 casts) revealed that the severity of sores was positively associated with increasing deltaT (OR: 2.100, P = 0.0005). The optimal cut-off values for the presence of SS and DS were set at, respectively, deltaT = 23 and 43 degrees C. Distal limb cast is a safe coaptation technique with increasing risk of developing sores with time. Thermography is a valuable and rapid clinical tool to monitor the development of cast sores.
Development and Implementation of the Casting of Rods Made of Refractory Cast Alloys
NASA Astrophysics Data System (ADS)
Kabanov, I. V.; Urin, S. L.; Ivanyuk, A. S.; Nesterov, A. N.; Bogdanov, S. V.
2017-12-01
The problems of the production of a so-called casting rod blank made of a refractory casting alloy in the vacuum induction furnaces of AO Metallurgical Plant Electrostal are considered. A unique technology of casting and subsequent treatment of as-cast rod blanks made of refractory alloys is developed, tested, and optimized. As a result of the developed and performed measures for the production of metal products in the Consarc furnace, the ingot-to-product yield increases by 15% as compared to metal casting in an ISV-1.0 furnace. As a result, we have widened the range of cast alloy grades and are going to cast metals for the manufacture of blanks of other sizes and ranges of alloy an steel grades.
Energy Consumption of Die Casting Operations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jerald Brevick; clark Mount-Campbell; Carroll Mobley
2004-03-15
Molten metal processing is inherently energy intensive and roughly 25% of the cost of die-cast products can be traced to some form of energy consumption [1]. The obvious major energy requirements are for melting and holding molten alloy in preparation for casting. The proper selection and maintenance of melting and holding equipment are clearly important factors in minimizing energy consumption in die-casting operations [2]. In addition to energy consumption, furnace selection also influences metal loss due to oxidation, metal quality, and maintenance requirements. Other important factors influencing energy consumption in a die-casting facility include geographic location, alloy(s) cast, starting formmore » of alloy (solid or liquid), overall process flow, casting yield, scrap rate, cycle times, number of shifts per day, days of operation per month, type and size of die-casting form of alloy (solid or liquid), overall process flow, casting yield, scrap rate, cycle times, number of shifts per day, days of operation per month, type and size of die-casting machine, related equipment (robots, trim presses), and downstream processing (machining, plating, assembly, etc.). Each of these factors also may influence the casting quality and productivity of a die-casting enterprise. In a die-casting enterprise, decisions regarding these issues are made frequently and are based on a large number of factors. Therefore, it is not surprising that energy consumption can vary significantly from one die-casting enterprise to the next, and within a single enterprise as function of time.« less
Mackintosh, Stephen; Buchanan, Samantha; Schwarzenlander, Kerstin; De Ruyter, Bernadette
2017-01-01
Objectives We investigated popliteal venous haemodynamics of the VenaJet Jet Impulse Technology system within a below-knee fibreglass cast. Design Randomized controlled trial. Participants Twenty-four healthy participants aged 18–54 had both feet placed within the Jet Impulse Technology system and were randomised for one or other leg to be within a below-knee fibreglass cast. Setting Pacific Radiology, Lower Hutt, Wellington Main outcome measures The primary outcome variable was peak systolic velocity (cm/s) compared between legs with and without the cast at 60 min (after 10 min Jet Impulse Technology activation), using a mixed linear model and a non-inferiority bound of 4.8 cm/s. Secondary outcome variables were the difference in peak systolic velocity between the casted limb and the non-casted limb at baseline and 40 min after casting, and the difference in mean flow velocity (cm/s), vein diameter (mm), and total volume flow (L/min) between the casted limb and the non-casted limb at baseline, 40 and 60 min. Results The mean (standard deviation) peak systolic velocity was 4.6(1.5), 4.8(1.1), 28.8(16.1), and 4.3(1.2), 4.8(1.4) and 29.3(19.0) cm/s at baseline, 40 and 60 min in the casted and non-casted leg, respectively. The difference (95% confidence interval) between cast and no-cast at 60 min was −0.8 (−6.5 to 4.9) cm/s, P = 0.78. The peak systolic velocity, flow velocity and total volume flow at 40 min were not statistically significantly different from baseline for both casted and non-casted limb. Conclusion In healthy volunteers, the popliteal venous haemodynamics of the Jet Impulse Technology system was similar between the legs with and without a below-knee fibreglass cast. In-cast Jet Impulse Technology may provide a non-pharmacological option for venous thromboembolism prophylaxis for lower-limb cast-immobility. PMID:28203384
Alex, Deepa; Shetty, Y. Bharath; Miranda, Glynis Anita; Prabhu, M. Bharath; Karkera, Reshma
2015-01-01
Background: Conventional investing and casting techniques are time-consuming and usually requires 2–4 h for completion. Accelerated nonstandard, casting techniques have been reported to achieve similar quality results in significantly less time, namely, in 30–40 min. During casting, it is essential to achieve compensation for the shrinkage of solidifying alloy by investment expansion. The metal casting ring restricts the thermal expansion of investment because the thermal expansion of the ring is lesser than that of the investment. The use of casting ring was challenged with the introduction of the ringless technique. Materials and Methods: A total of 40 test samples of nickel chromium (Ni-Cr) cast copings were obtained from the patterns fabricated using inlay casting wax. The 20 wax patterns were invested using metal ring and 20 wax patterns were invested using the ringless investment system. Of both the groups, 10 samples underwent conventional casting, and the other 10 underwent accelerated casting. The patterns were casted using the induction casting technique. All the test samples of cast copings were evaluated for vertical marginal gaps at four points on the die employing a stereo optical microscope. Results: The vertical marginal discrepancy data obtained were tabulated. Mean and standard deviations were obtained. Vertical discrepancies were analyzed using analysis of variance and Tukey honestly significantly different. The data obtained were found to be very highly significant (P < 0.001). Mean vertical gap was the maximum for Group II (53.64 μm) followed by Group IV (47.62 μm), Group I (44.83 μm) and Group III (35.35 μm). Conclusion: The Ni-Cr cast copings fabricated with the conventional casting using ringless investment system showed significantly better marginal fit than that of cast copings fabricated from conventional and accelerated casting with metal ring investment and accelerated casting using ringless investment since those copings had shown the least vertical marginal discrepancies among the four methods evaluated in this study. PMID:26929488
Factors contributing to the temperature beneath plaster or fiberglass cast material
Hutchinson, Michael J; Hutchinson, Mark R
2008-01-01
Background Most cast materials mature and harden via an exothermic reaction. Although rare, thermal injuries secondary to casting can occur. The purpose of this study was to evaluate factors that contribute to the elevated temperature beneath a cast and, more specifically, evaluate the differences of modern casting materials including fiberglass and prefabricated splints. Methods The temperature beneath various types (plaster, fiberglass, and fiberglass splints), brands, and thickness of cast material were measured after they were applied over thermometer which was on the surface of a single diameter and thickness PVC tube. A single layer of cotton stockinette with variable layers and types of cast padding were placed prior to application of the cast. Serial temperature measurements were made as the cast matured and reached peak temperature. Time to peak, duration of peak, and peak temperature were noted. Additional tests included varying the dip water temperature and assessing external insulating factors. Ambient temperature, ambient humidity and dip water freshness were controlled. Results Outcomes revealed that material type, cast thickness, and dip water temperature played key roles regarding the temperature beneath the cast. Faster setting plasters achieved peak temperature quicker and at a higher level than slower setting plasters. Thicker fiberglass and plaster casts led to greater peak temperature levels. Likewise increasing dip-water temperature led to elevated temperatures. The thickness and type of cast padding had less of an effect for all materials. With a definition of thermal injury risk of skin injury being greater than 49 degrees Celsius, we found that thick casts of extra fast setting plaster consistently approached dangerous levels (greater than 49 degrees for an extended period). Indeed a cast of extra-fast setting plaster, 20 layers thick, placed on a pillow during maturation maintained temperatures over 50 degrees of Celsius for over 20 minutes. Conclusion Clinicians should be cautious when applying thick casts with warm dip water. Fast setting plasters have increased risk of thermal injury while brand does not appear to play a significant role. Prefabricated fiberglass splints appear to be safer than circumferential casts. The greatest risk of thermal injury occurs when thick casts are allowed to mature while resting on pillow. PMID:18298851
Non-rigid Reconstruction of Casting Process with Temperature Feature
NASA Astrophysics Data System (ADS)
Lin, Jinhua; Wang, Yanjie; Li, Xin; Wang, Ying; Wang, Lu
2017-09-01
Off-line reconstruction of rigid scene has made a great progress in the past decade. However, the on-line reconstruction of non-rigid scene is still a very challenging task. The casting process is a non-rigid reconstruction problem, it is a high-dynamic molding process lacking of geometric features. In order to reconstruct the casting process robustly, an on-line fusion strategy is proposed for dynamic reconstruction of casting process. Firstly, the geometric and flowing feature of casting are parameterized in manner of TSDF (truncated signed distance field) which is a volumetric block, parameterized casting guarantees real-time tracking and optimal deformation of casting process. Secondly, data structure of the volume grid is extended to have temperature value, the temperature interpolation function is build to generate the temperature of each voxel. This data structure allows for dynamic tracking of temperature of casting during deformation stages. Then, the sparse RGB features is extracted from casting scene to search correspondence between geometric representation and depth constraint. The extracted color data guarantees robust tracking of flowing motion of casting. Finally, the optimal deformation of the target space is transformed into a nonlinear regular variational optimization problem. This optimization step achieves smooth and optimal deformation of casting process. The experimental results show that the proposed method can reconstruct the casting process robustly and reduce drift in the process of non-rigid reconstruction of casting.
Characterization of Ni-Cr alloys using different casting techniques and molds.
Chen, Wen-Cheng; Teng, Fu-Yuan; Hung, Chun-Cheng
2014-02-01
This study differentiated the mechanical properties of nickel-chromium (Ni-Cr) alloys under various casting techniques (different casting molds and casting atmospheres). These techniques were sampled by a sand mold using a centrifugal machine in ambient air (group I) and electromagnetic induction in an automatic argon castimatic casting machine (group II). The specimen casting used a graphite mold by a castimatic casting machine (group III). The characteristics of the Ni-Cr alloys, yield and ultimate tensile strength, bending modulus, microhardness, diffraction phase, grindability, ability to spring back, as well as ground microstructure and pattern under different casting conditions were evaluated. The group III specimens exhibited the highest values in terms of strength, modulus, hardness, and grindability at a grind rate of 500 rpm. Moreover, group III alloys exhibited smaller grain sizes, higher ability to spring back, and greater ductility than those casted by sand investment (groups I and II). The main factor, "casting mold," significantly influenced all mechanical properties. The graphite mold casting of the Ni-Cr dental alloys in a controlled atmosphere argon casting system provided an excellent combination of high mechanical properties and good ability to spring back, and preserved the ductile properties for application in Ni-Cr porcelain-fused system. The results can offer recommendations to assist a prosthetic technician in selecting the appropriate casting techniques to obtain the desired alloy properties. Copyright © 2013 Elsevier B.V. All rights reserved.
40 CFR 464.30 - Applicability; description of the ferrous casting subcategory.
Code of Federal Regulations, 2010 CFR
2010-07-01
... ferrous casting subcategory. 464.30 Section 464.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS METAL MOLDING AND CASTING POINT SOURCE CATEGORY Ferrous Casting Subcategory § 464.30 Applicability; description of the ferrous casting subcategory. The...
Microstructural Evolution in Intensively Melt Sheared Direct Chill Cast Al-Alloys
NASA Astrophysics Data System (ADS)
Jones, S.; Rao, A. K. Prasada; Patel, J. B.; Scamans, G. M.; Fan, Z.
The work presented here introduces the novel melt conditioned direct chill casting (MC-DC) technology, where intensive melt shearing is applied to the conventional direct-chill casting process. MC-DC casting can successfully produce high quality Al-alloy billets. The results obtained from 80 mm diameter billets cast at speed of 200 mm/min show that MC-DC casting of Al-alloys, substantially refines the microstructure and reduces macro-segregation. In this paper, we present the preliminary results and discuss microstructural evolution during MC-DC casting of Al-alloys.
Driving with a short arm cast in a simulator.
Mansour, Damian; Mansour, Kristin Gotaas; Kenny, Benjamin William; Attia, John; Meads, Bryce
2015-12-01
To test the ability to steer in a driving simulator in subjects with a short arm cast. 17 men and 13 women aged 23 to 67 (mean, 37) years who had a valid driver's licence were randomised to the cast-first group (n=16; 7 had the cast on the dominant arm) or the cast-second group (n=14; 8 had the cast on the dominant arm) and drove in a simulator. A short arm plaster-of-Paris cast was applied in a neutral position, allowing free movement of the metacarpophalangeal joints, thumb, and elbow joint. Outcome measures included the number of driving off track instances, the number of crashes, the lap time, and the effect of hand dominance on these parameters. Subjects were asked whether the cast had impeded their steering ability. Subjects with or without a cast were comparable in terms of the number of driving off track instances, number of crashes, and lap time. Compared with no cast, the odds ratio (OR) of a subject in a cast driving off the track was 1.02 (p=0.921) and having a crash was 0.79 (p=0.047). All subjects were 1.23 times more likely to drive off the track in their first lap (OR=2.66, p=0.019). The mean lap time decreased for each consecutive lap from the 2nd to 5th laps. Subjects driving with a cast on the dominant or non-dominant arm were comparable. 26 out of the 30 participants considered that the plaster cast impeded their steering ability. Compared with no cast, driving with a short arm cast did not significantly decrease steering ability in a driving simulator.
Quiet breathing in hindlimb casted mice.
Receno, Candace N; Roffo, Katelynn E; Mickey, Marisa C; DeRuisseau, Keith C; DeRuisseau, Lara R
2018-06-07
The hindlimb casting model was developed to study skeletal muscle reloading following a period of unloading. It is unknown if ventilation parameters of mice are affected by the casting model. We tested the hypothesis that hindlimb casted mice have similar ventilatory patterns compared to mice with the casts removed. Male CD-1 mice underwent 14 days of hindlimb immobilization via plaster casting. Breathing parameters were obtained utilizing unrestrained barometric plethysmography (UBP). Breathing traces were analyzed with Ponemah software for breathing frequency, tidal volume (TV), and minute ventilation (MV). Frequency, TV and MV did not show any differences in quiet breathing patterns during or post-casting in mice. Thus, the hindlimb casting model does not complicate breathing during and after casting and should not interfere with the unloading and reloading of skeletal muscle. Copyright © 2018 Elsevier B.V. All rights reserved.
40 CFR 464.10 - Applicability; description of the aluminum casting subcategory.
Code of Federal Regulations, 2010 CFR
2010-07-01
... aluminum casting subcategory. 464.10 Section 464.10 Protection of Environment ENVIRONMENTAL PROTECTION... Aluminum Casting Subcategory § 464.10 Applicability; description of the aluminum casting subcategory. The... introduction of pollutants into publicly owned treatment works resulting from aluminum casting operations as...
40 CFR 464.20 - Applicability; description of the copper casting subcategory.
Code of Federal Regulations, 2011 CFR
2011-07-01
... copper casting subcategory. 464.20 Section 464.20 Protection of Environment ENVIRONMENTAL PROTECTION... Copper Casting Subcategory § 464.20 Applicability; description of the copper casting subcategory. The... introduction of pollutants into publicly owned treatment works resulting from copper casting operations as...
40 CFR 464.20 - Applicability; description of the copper casting subcategory.
Code of Federal Regulations, 2010 CFR
2010-07-01
... copper casting subcategory. 464.20 Section 464.20 Protection of Environment ENVIRONMENTAL PROTECTION... Copper Casting Subcategory § 464.20 Applicability; description of the copper casting subcategory. The... introduction of pollutants into publicly owned treatment works resulting from copper casting operations as...
Method of reducing the green density of a slip cast article
Mangels, John A.; Dickie, Ray A.
1985-01-01
The method disclosed in this specification is one of reducing the green density of an article cast in a slip casting operation. The article is cast from a casting slip containing silicon metal particles, yttrium containing particles, and a small amount of a fluoride salt which is effective to suppress flocculation of the silicon metal particles by y.sup.+3 ions derived from the yttrium containing particles. The method is characterized by the following step. A small amount of compound which produces a cation which will partly flocculate the particles of silicon metal is added to the casting slip. The small amount of this compound is added so that when the casting slip is slip cast into a casting mold, the partly flocculated particles of silicon will interrupt an otherwise orderly packing of the particles of silicon and particles of yttrium. In this manner, the green density of the slip cast article is reduced and the article may be more easily nitrided.
Management of Intolerance to Casting the Upper Extremities in Claustrophobic Patients
Nagura, Issei; Kanatani, Takako; Sumi, Masatoshi; Inui, Atsuyuki; Mifune, Yutaka; Kokubu, Takeshi; Kurosaka, Masahiro
2014-01-01
Introduction. Some patients showed unusual responses to the immobilization without any objective findings with casts in upper extremities. We hypothesized their that intolerance with excessive anxiety to casts is due to claustrophobia triggered by cast immobilization. The aim of this study is to analyze the relevance of cast immobilization to the feeling of claustrophobia and discover how to handle them. Methods. There were nine patients who showed the caustrophobic symptoms with their casts. They were assesed whether they were aware of their claustrophobis themselves. Further we investigated the alternative immobilization to casts. Results. Seven out of nine cases that were aware of their claustrophobic tendencies either were given removable splints initially or had the casts converted to removable splints when they exhibited symptoms. The two patients who were unaware of their latent claustrophobic tendencies were identified when they showed similar claustrophobic symptoms to the previous patients soon after short arm cast application. We replaced the casts with removable splints. This resolved the issue in all cases. Conclusions. We should be aware of the claustrophobia if patients showed unusual responses to the immobilization without any objective findings with casts in upper extremities, where removal splint is practical alternative to cast to continue the treatment successfully. PMID:25379544
AMCC casting development, volume 2
NASA Technical Reports Server (NTRS)
1995-01-01
PCC successfully cast and performed nondestructive testing, FPI and x-ray, on seventeen AMCC castings. Destructive testing, lab analysis and chemical milling, was performed on eleven of the castings and the remaining six castings were shipped to NASA or Aerojet. Two of the six castings shipped, lots 015 and 016, were fully processed per blueprint requirements. PCC has fully developed the gating and processing parameters of this part and feels the part could be implemented into production, after four more castings have been completed to ensure the repeatability of the process. The AMCC casting has been a technically challenging part due to its size, configuration, and alloy type. The height and weight of the wax pattern assembly necessitated the development of a hollow gating system to ensure structural integrity of the shell throughout the investment process. The complexity in the jacket area of the casting required the development of an innovative casting technology that PCC has termed 'TGC' or thermal gradient control. This method of setting up thermal gradients in the casting during solidification represents a significant process improvement for PCC and has been successfully implemented on other programs. The alloy, JBK75, is a relatively new alloy in the investment casting arena and required our engineering staff to learn the gating, processing, and dimensional characteristics of the material.
NASA Astrophysics Data System (ADS)
Kabnure, Bahubali Bhupal; Shinde, Vasudev Dhondiram; Kolhapure, Rakesh Ramchandra
2018-05-01
Ductile irons are important engineering materials because of its high strength to weight ratio and castability. The ductile iron castings are used widely for automobile applications due to their wide spectrum of property range. Weight reduction is important in automobile to improve its fuel efficiency which can be achieved by thinning down the casting sections without altering its functionality. Generally, automobile castings are having varying section thickness. Varying thickness castings offers different cooling rates while solidification of the casting. The solidification cooling rate decides the final microstructure of the cast components. Cooling rate was found to affect directly the amount of pearlite and ultimately the as cast properties in varying thickness ductile iron castings. In view of this, the automobile impeller casting is selected for study in the present work as it consists of varying section thickness in which small sections are connected to central hub. The casting solidification simulations were performed and analyzed. The solidification cooling rates were analyzed further to correlate the experimental processing parameters. The samples from poured castings were analyzed for microstructure and hardness at different section thickness. Multiple response optimization of microstructure and hardness was carried out by combined Taguchi and Grey Relational Analysis (GRA). Contribution of input variables on the output variables is attained using ANOVA.
Macchi, Veronica; Picardi, Edgardo; Inferrera, Antonino; Porzionato, Andrea; Crestani, Alessandro; Novara, Giacomo; De Caro, Raffaele; Ficarra, Vincenzo
2018-02-01
The aim of the present anatomic and radiologic study was to evaluate the location, extension, and characteristics of the Brödel's plane and eventually define its different patterns. We evaluated 15 human normal kidneys sampled from unembalmed cadavers without clinical history or anatomical evidence of renal diseases. Kidneys with the surrounding perirenal fat tissue were removed en bloc with the abdominal segment of the aorta. The renal artery was injected with acrylic and radiopaque resins. A CT examination of the injected kidneys was performed. After the imaging acquisition, the specimens were treated with sodium hydroxide for removal of the parenchyma to obtain the vascular casts. All the CT images were elaborated using dedicated three-dimensional (3D) software with the aim to improve the possibility to identify the Brödel's plane. The avascular plane was identified directly on the vascular casts and confirmed on the corresponding 3D images. The avascular plane was located in all cases medially to the lateral convex border of the kidneys. The recorded mean distance was 2.04 cm (range 1.8-2.4 cm). Three patterns of distribution of the Brödel's line were identified. In five (33.3%) cases the avascular plane was extended from the apical to the inferior segment of the kidneys (type 1); in six (40%) from the superior to the inferior segment (type 2); and in four (26.7%) from the apical to the middle segment (type 3). Fourth and fifth order vessels crossing the Brödel's line were detected in all the analyzed cases. The renal avascular plane showed a different extension allowing us to cluster three different patterns. Preoperative identification of the Brödel's line patterns could help surgeons to minimize hemorrhagic complications during percutaneous and surgical procedures requiring an incision of the renal parenchyma such as traditional or robot-assisted nephrolithotomy or partial nephrectomy for endophytic renal tumors. Radiologic studies validated that the described patterns in the clinical practice are strongly needed.
Seah, Richard; Mani-Babu, Sivanadian
2011-01-01
To summarize the best available evidence in the last decade for managing ankle sprains in the community, data were collected using MEDLINE database from January 2000 to December 2009. Terms utilized: 'ankle injury primary care' (102 articles were found), 'ankle sprain primary care' (34 articles), 'ankle guidelines primary care' (25 articles), 'ankle pathways primary care' (2 articles), 'ankle sprain community' (18 articles), 'ankle sprain general practice' (22 articles), 'Cochrane review ankle' (58 articles). Of these, only 33 satisfied the inclusion criteria. The search terms identified many of the same studies. Two independent reviewers reviewed the articles. The study results and generated conclusions were extracted, discussed and finally agreed on. Ankle sprains occur commonly but their management is not always readily agreed. The Ottawa Ankle Rules are ubiquitous in the clinical pathway and can be reliably applied by emergency care physicians, primary care physicians and triage nurses. For mild-to-moderate ankle sprains, functional treatment options (which can consist of elastic bandaging, soft casting, taping or orthoses with associated coordination training) were found to be statistically better than immobilization for multiple outcome measures. For severe ankle sprains, a short period of immobilization in a below-knee cast or pneumatic brace results in a quicker recovery than tubular compression bandage alone. Lace-up supports are a more effective functional treatment than elastic bandaging and result in less persistent swelling in the short term when compared with semi-rigid ankle supports, elastic bandaging and tape. Semi-rigid orthoses and pneumatic braces provide beneficial ankle support and may prevent subsequent sprains during high-risk sporting activity. Supervised rehabilitation training in combination with conventional treatment for acute lateral ankle sprains can be beneficial, although some of the studies reviewed gave conflicting outcomes. Therapeutic hyaluronic acid injections in the ankle are a relatively novel non-surgical treatment but may have a role in expediting return to sport after ankle sprain. There is a role for surgical intervention in severe acute and chronic ankle injuries, but the evidence is limited.
NASA Astrophysics Data System (ADS)
Singh, Rupinder
2018-02-01
Hot chamber (HC) die casting process is one of the most widely used commercial processes for the casting of low temperature metals and alloys. This process gives near-net shape product with high dimensional accuracy. However in actual field environment the best settings of input parameters is often conflicting as the shape and size of the casting changes and one have to trade off among various output parameters like hardness, dimensional accuracy, casting defects, microstructure etc. So for online inspection of the cast components properties (without affecting the production line) the weight measurement has been established as one of the cost effective method (as the difference in weight of sound and unsound casting reflects the possible casting defects) in field environment. In the present work at first stage the effect of three input process parameters (namely: pressure at 2nd phase in HC die casting; metal pouring temperature and die opening time) has been studied for optimizing the cast component weight `W' as output parameter in form of macro model based upon Taguchi L9 OA. After this Buckingham's π approach has been applied on Taguchi based macro model for the development of micro model. This study highlights the Taguchi-Buckingham based combined approach as a case study (for conversion of macro model into micro model) by identification of optimum levels of input parameters (based on Taguchi approach) and development of mathematical model (based on Buckingham's π approach). Finally developed mathematical model can be used for predicting W in HC die casting process with more flexibility. The results of study highlights second degree polynomial equation for predicting cast component weight in HC die casting and suggest that pressure at 2nd stage is one of the most contributing factors for controlling the casting defect/weight of casting.
41. PHOTOGRAPHY OF BLUE PRINT (MINNEAPOLIS CITY ENGINEER) END AND ...
41. PHOTOGRAPHY OF BLUE PRINT (MINNEAPOLIS CITY ENGINEER) END AND CENTRE CASTING OF CAST STEEL, MASONRY CASTING OF CAST IRON CASTING, FOR MINNEAPOLIS STEEL ARCH (4 x 5 negative) - Steel Arch Bridge, Hennepin Avenue spanning west channel of Mississippi River, Minneapolis, Hennepin County, MN
Basic Casting from A to Z. Student's Instruction Booklet.
ERIC Educational Resources Information Center
Zebco, Tulsa, OK.
A profusely illustrated student instruction booklet contains step-by-step directions and diagrams for learning four basic casting techniques. Separate sections cover basic spin-casting, spinning, bait-casting, and fly-casting. Each section details recommended equipment (reel, rod, line, plug, tackle, lures, leaders, flies), describes specific…
Genetic evidence on the origins of Indian caste populations.
Bamshad, M; Kivisild, T; Watkins, W S; Dixon, M E; Ricker, C E; Rao, B B; Naidu, J M; Prasad, B V; Reddy, P G; Rasanayagam, A; Papiha, S S; Villems, R; Redd, A J; Hammer, M F; Nguyen, S V; Carroll, M L; Batzer, M A; Jorde, L B
2001-06-01
The origins and affinities of the approximately 1 billion people living on the subcontinent of India have long been contested. This is owing, in part, to the many different waves of immigrants that have influenced the genetic structure of India. In the most recent of these waves, Indo-European-speaking people from West Eurasia entered India from the Northwest and diffused throughout the subcontinent. They purportedly admixed with or displaced indigenous Dravidic-speaking populations. Subsequently they may have established the Hindu caste system and placed themselves primarily in castes of higher rank. To explore the impact of West Eurasians on contemporary Indian caste populations, we compared mtDNA (400 bp of hypervariable region 1 and 14 restriction site polymorphisms) and Y-chromosome (20 biallelic polymorphisms and 5 short tandem repeats) variation in approximately 265 males from eight castes of different rank to approximately 750 Africans, Asians, Europeans, and other Indians. For maternally inherited mtDNA, each caste is most similar to Asians. However, 20%-30% of Indian mtDNA haplotypes belong to West Eurasian haplogroups, and the frequency of these haplotypes is proportional to caste rank, the highest frequency of West Eurasian haplotypes being found in the upper castes. In contrast, for paternally inherited Y-chromosome variation each caste is more similar to Europeans than to Asians. Moreover, the affinity to Europeans is proportionate to caste rank, the upper castes being most similar to Europeans, particularly East Europeans. These findings are consistent with greater West Eurasian male admixture with castes of higher rank. Nevertheless, the mitochondrial genome and the Y chromosome each represents only a single haploid locus and is more susceptible to large stochastic variation, bottlenecks, and selective sweeps. Thus, to increase the power of our analysis, we assayed 40 independent, biparentally inherited autosomal loci (1 LINE-1 and 39 Alu elements) in all of the caste and continental populations (approximately 600 individuals). Analysis of these data demonstrated that the upper castes have a higher affinity to Europeans than to Asians, and the upper castes are significantly more similar to Europeans than are the lower castes. Collectively, all five datasets show a trend toward upper castes being more similar to Europeans, whereas lower castes are more similar to Asians. We conclude that Indian castes are most likely to be of proto-Asian origin with West Eurasian admixture resulting in rank-related and sex-specific differences in the genetic affinities of castes to Asians and Europeans.
Genetic Evidence on the Origins of Indian Caste Populations
Bamshad, Michael; Kivisild, Toomas; Watkins, W. Scott; Dixon, Mary E.; Ricker, Chris E.; Rao, Baskara B.; Naidu, J. Mastan; Prasad, B.V. Ravi; Reddy, P. Govinda; Rasanayagam, Arani; Papiha, Surinder S.; Villems, Richard; Redd, Alan J.; Hammer, Michael F.; Nguyen, Son V.; Carroll, Marion L.; Batzer, Mark A.; Jorde, Lynn B.
2001-01-01
The origins and affinities of the ∼1 billion people living on the subcontinent of India have long been contested. This is owing, in part, to the many different waves of immigrants that have influenced the genetic structure of India. In the most recent of these waves, Indo-European-speaking people from West Eurasia entered India from the Northwest and diffused throughout the subcontinent. They purportedly admixed with or displaced indigenous Dravidic-speaking populations. Subsequently they may have established the Hindu caste system and placed themselves primarily in castes of higher rank. To explore the impact of West Eurasians on contemporary Indian caste populations, we compared mtDNA (400 bp of hypervariable region 1 and 14 restriction site polymorphisms) and Y-chromosome (20 biallelic polymorphisms and 5 short tandem repeats) variation in ∼265 males from eight castes of different rank to ∼750 Africans, Asians, Europeans, and other Indians. For maternally inherited mtDNA, each caste is most similar to Asians. However, 20%–30% of Indian mtDNA haplotypes belong to West Eurasian haplogroups, and the frequency of these haplotypes is proportional to caste rank, the highest frequency of West Eurasian haplotypes being found in the upper castes. In contrast, for paternally inherited Y-chromosome variation each caste is more similar to Europeans than to Asians. Moreover, the affinity to Europeans is proportionate to caste rank, the upper castes being most similar to Europeans, particularly East Europeans. These findings are consistent with greater West Eurasian male admixture with castes of higher rank. Nevertheless, the mitochondrial genome and the Y chromosome each represents only a single haploid locus and is more susceptible to large stochastic variation, bottlenecks, and selective sweeps. Thus, to increase the power of our analysis, we assayed 40 independent, biparentally inherited autosomal loci (1 LINE-1 and 39 Alu elements) in all of the caste and continental populations (∼600 individuals). Analysis of these data demonstrated that the upper castes have a higher affinity to Europeans than to Asians, and the upper castes are significantly more similar to Europeans than are the lower castes. Collectively, all five datasets show a trend toward upper castes being more similar to Europeans, whereas lower castes are more similar to Asians. We conclude that Indian castes are most likely to be of proto-Asian origin with West Eurasian admixture resulting in rank-related and sex-specific differences in the genetic affinities of castes to Asians and Europeans. PMID:11381027
Caste, Class and the Love-Marriage: Social Change in India
ERIC Educational Resources Information Center
Corwin, Lauren A.
1977-01-01
The present study of a small town in rural West Bengal, India, reveals a number of "love-marriages" involving individuals from castes of distinctly different ranks in the local caste hierarchy. Despite the prevailing rule of caste endogamy, inter-caste couples appear to face little difficulty. (Author)
Release of ToxCastDB and ExpoCastDB databases
EPA has released two databases - the Toxicity Forecaster database (ToxCastDB) and a database of chemical exposure studies (ExpoCastDB) - that scientists and the public can use to access chemical toxicity and exposure data. ToxCastDB users can search and download data from over 50...
Adhesion Casting In Low Gravity
NASA Technical Reports Server (NTRS)
Noever, David A.; Cronise, Raymond J.
1996-01-01
Adhesion casting in low gravity proposed as technique for making new and improved materials. Advantages of low-gravity adhesion casting, in comparison with adhesion casting in normal Earth gravity, comes from better control over, and greater uniformity of, thicknesses of liquid films that form on and adhere to solid surfaces during casting.
40 CFR 466.20 - Applicability; description of the cast iron basis material subcategory.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Applicability; description of the cast... Cast Iron Basis Material Subcategory § 466.20 Applicability; description of the cast iron basis... of pollutants into publicly owned treatment works from porcelain enameling of cast iron basis...
CAST FLOOR WITH VIEW OF TORPEDO LADLE (BENEATH CAST FLOOR) ...
CAST FLOOR WITH VIEW OF TORPEDO LADLE (BENEATH CAST FLOOR) AND KEEPERS OF THE CAST HOUSE FLOOR, S.L. KIMBROUGH AND DAVID HOLMES. - U.S. Steel, Fairfield Works, Blast Furnace No. 8, North of Valley Road, West of Ensley-Pleasant Grove Road, Fairfield, Jefferson County, AL
Applied anatomy of a new approach of endoscopic technique in thyroid gland surgery.
Liu, Hong; Xie, Yong-jun; Xu, Yi-quan; Li, Chao; Liu, Xing-guo
2012-10-01
To explore the feasibility and safety of transtracheal assisted sublingual approach to totally endoscopic thyroidectomy by studying the anatomical approach and adjacent structures. A total of 5 embalmed adult cadavers from Chengdu Medical College were dissected layer by layer in the cervical region, pharyngeal region, and mandible region, according to transtracheal assisted sublingual approach that was verified from the anatomical approach and planes. A total of 15 embalmed adult cadavers were dissected by arterial vascular casting technique, imaging scanning technique, and thin layer cryotomy. Then the vessel and anatomical structures of thyroid surgical region were analyzed qualitatively and quantitatively. Three-dimensional visualization of larynx artery was reconstructed by Autodesk 3ds Max 2010(32). Transtracheal assisted sublingual approach for totally endoscopic thyroidectomy was simulated on 5 embalmed adult cadavers. The sublingual observed access was located in the middle of sublingual region. The geniohyoid muscle, mylohyoid seam, and submental triangle were divided in turn in the middle to reach the plane under the plastima muscles. Superficial cervical fascia, anterior body of hyoid bone, and infrahyoid muscles were passed in sequence to reach thyroid gland surgical region. The transtracheal operational access was placed from the cavitas oris propria, isthmus faucium, subepiglottic region, laryngeal pharynx, and intermediate laryngeal cavit, and then passed from the top down in order to reach pars cervicalis tracheae where a sagittal incision was made in the anterior wall of cartilagines tracheales to reach a ascertained surgical region. Transtracheal assisted sublingual approach to totally endoscopic thyroidectomy is anatomically feasible and safe and can be useful in thyroid gland surgery.
Virtually fabricated guide for placement of the C-tube miniplate.
Paek, Janghyun; Jeong, Do-Min; Kim, Yong; Kim, Seong-Hun; Chung, Kyu-Rhim; Nelson, Gerald
2014-05-01
This paper introduces a virtually planned and stereolithographically fabricated guiding system that will allow the clinician to plan carefully for the best location of the device and to achieve an accurate position without complications. The scanned data from preoperative dental casts were edited to obtain preoperative 3-dimensional (3D) virtual models of the dentition. After the 3D virtual models were repositioned, the 3D virtual surgical guide was fabricated. A surgical guide was created onscreen, and then these virtual guides were materialized into real ones using the stereolithographic technique. Whereas the previously described guide required laboratory work to be performed by the orthodontist, our technique is more convenient because the laboratory work is done remotely by computer-aided design/computer-aided manufacturing technology. Because the miniplate is firmly held in place as the patient holds his or her mandibular teeth against the occlusal pad of the surgical guide, there is no risk that the miniscrews can slide on the bone surface during placement. The software program (2.5-dimensional software) in this study combines 2-dimensional cephalograms with 3D virtual dental models. This software is an effective and efficient alternative to 3D software when 3D computed tomography data are not available. To confidently and safely place a miniplate with screw fixation, a simple customized guide for an orthodontic miniplate was introduced. The use of a custom-made, rigid guide when placing miniplates will minimize complications such as vertical mislocation or slippage of the miniplate during placement. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Dense chitosan surgical membranes produced by a coincident compression-dehydration process
Dooley, Thomas P.; Ellis, April L.; Belousova, Maria; Petersen, Don; DeCarlo, Arthur A.
2012-01-01
High density chitosan membranes were produced via a novel manufacturing process for use as implantable resorbable surgical membranes. The innovative method utilizes the following three sequential steps: (1) casting an acidic chitosan solution within a silicon mold, followed by freezing; (2) neutralizing the frozen acidic chitosan solution in alkaline solution to facilitate polymerization; and (3) applying coincident compression-dehydration under a vacuum. Resulting membranes of 0.2 – 0.5 mm thickness have densities as high as 1.6 g/cm3. Inclusion of glycerol prior to the compression-dehydration step provides additional physical and clinical handling benefits. The biomaterials exhibit tensile strength with a maximum load as high as 10.9 N at ~ 2.5 mm width and clinically-relevant resistance to suture pull-out with a maximum load as high as 2.2 N. These physical properties were superior to those of a commercial reconstituted collagen membrane. The dense chitosan membranes have excellent clinical handling characteristics, such as pliability and “memory” when wet. They are semi-permeable to small molecules, biodegradable in vitro in lysozyme solution, and the rates of degradation are inversely correlated to the degree of deacetylation. Furthermore, the dense chitosan membranes are biocompatible and resorbable in vivo as demonstrated in a rat oral wound healing model. The unique combination of physical, in vitro, in vivo, and clinical handling properties demonstrate the high utility of dense chitosan membranes produced by this new method. The materials may be useful as surgical barrier membranes, scaffolds for tissue engineering, wound dressings, and as delivery devices for active ingredients. PMID:23565872
Adaptive significance of the Indian caste system: an ecological perspective.
Gadgil, M; Malhotra, K C
1983-01-01
Indian society is an agglomeration of several thousand endogamous groups or castes each with a restricted geographical range and a hereditarily determined mode of subsistence. These reproductively isolated castes may be compared to biological species, and the society thought of as a biological community with each caste having its specific ecological niche. In this paper we examine the ecological-niche relationships of castes which are directly dependent on natural resources. Evidence is presented to show that castes living together in the same region had so organized their pattern of resource use as to avoid excessive intercaste competition for limiting resources. Furthermore, territorial division of the total range of the caste regulated intra-caste competition. Hence, a particular plant or animal resource in a given locality was used almost exclusively by a given lineage within a caste generation after generation. This favoured the cultural evolution of traditions ensuring sustainable use of natural resources. This must have contributed significantly to the stability of Indian caste society over several thousand years. The collapse of the base of natural resources and increasing monetarization of the economy has, however, destroyed the earlier complementarity between the different castes and led to increasing conflicts between them in recent years.
NASA Astrophysics Data System (ADS)
Sheng, L. Y.; Du, B. N.; Guo, J. T.
2017-01-01
NiAl based materials has been considered as most potential candidate of turbine blade, due to its excellent high-temperature properties. However the bad room-temperature properties handicap its application. In the present paper, the zirconium doped NiAl/Cr(Mo) hypoeutectic alloy is fabricated by conventional casting and injection casting technology to improve its room-temperature properties. The microstructure and compressive properties at different temperatures of the conventionally-cast and injection-cast were investigated. The results exhibit that the conventionally-cast alloy comprises coarse primary NiAl phase and eutectic cell, which is dotted with irregular Ni2AlZr Heusler phase. Compared with the conventionally-cast alloy, the injection-cast alloy possesses refined the primary NiAl, eutectic cell and eutectic lamella. In addition, the Ni2AlZr Heusler phase become smaller and distribute uniformly. Moreover, the injection casting decrease the area fraction of primary NiAl phase at the cell interior or cell boundaries. The compressive ductility and yield strength of the injection-cast alloy at room temperature increase by about 100% and 35% over those of conventionally-cast alloy, which should be ascribed to the microstructure optimization.
The Soldiers in Societies: Defense, Regulation, and Evolution
Tian, Li; Zhou, Xuguo
2014-01-01
The presence of reproductively altruistic castes is one of the primary traits of the eusocial societies. Adaptation and regulation of the sterile caste, to a certain extent, drives the evolution of eusociality. Depending on adaptive functions of the first evolved sterile caste, eusocial societies can be categorized into the worker-first and soldier-first lineages, respectively. The former is marked by a worker caste as the first evolved altruistic caste, whose primary function is housekeeping, and the latter is highlighted by a sterile soldier caste as the first evolved altruistic caste, whose task is predominantly colony defense. The apparent functional differences between these two fundamentally important castes suggest worker-first and soldier-first eusociality are potentially driven by a suite of distinctively different factors. Current studies of eusocial evolution have been focused largely on the worker-first Hymenoptera, whereas understanding of soldier-first lineages including termites, eusocial aphids, gall-dwelling thrips, and snapping shrimp, is greatly lacking. In this review, we summarize the current state of knowledge on biology, morphology, adaptive functions, and caste regulation of the soldier caste. In addition, we discuss the biological, ecological and genetic factors that might contribute to the evolution of distinct caste systems within eusocial lineages. PMID:24644427
Analysis of Mold Friction in a Continuous Casting Using Wavelet Transform
NASA Astrophysics Data System (ADS)
Ma, Yong; Fang, Bohan; Ding, Qiqi; Wang, Fangyin
2018-04-01
Mold friction (MDF) is an important parameter reflecting the lubrication condition between the initial shell and the mold during continuous casting. In this article, based on practical MDF from the slab continuous casting driven by a mechanical vibration device, the characteristics of friction were analyzed by continuous wavelet transform (CWT) and discrete wavelet transform (DWT) in different casting conditions, such as normal casting, level fluctuation, and alarming of the temperature measurement system. The results show that the CWT of friction accurately captures the subtle changes in friction force, such as the periodic characteristic of MDF during normal casting and the disordered feature of MDF during level fluctuation. Most important, the results capture the occurrence of abnormal casting and display the friction frequency characteristics at this abnormal time. In addition, in this article, there are some abnormal casting conditions, and the friction signal is stable until there is a sudden large change when abnormal casting, such as split breakout and submerged entry nozzle breakage, occurs. The DWT has a good ability to capture the friction characteristics for such abnormal situations. In particular, the potential abnormal features of MDF were presented in advance, which provides strong support for identifying abnormal casting and even preventing abnormal casting.
Very High Cycle Fatigue Behavior of a Directionally Solidified Ni-Base Superalloy DZ4
Nie, Baohua; Zhao, Zihua; Liu, Shu; Chen, Dongchu; Ouyang, Yongzhong; Hu, Zhudong; Fan, Touwen; Sun, Haibo
2018-01-01
The effect of casting pores on the very high cycle fatigue (VHCF) behavior of a directionally solidified (DS) Ni-base superalloy DZ4 is investigated. Casting and hot isostatic pressing (HIP) specimens were subjected to very high cycle fatigue loading in an ambient atmosphere. The results demonstrated that the continuously descending S-N curves were exhibited for both the casting and HIP specimens. Due to the elimination of the casting pores, the HIP samples had better fatigue properties than the casting samples. The subsurface crack initiated from the casting pore in the casting specimens at low stress amplitudes, whereas fatigue crack initiated from crystallographic facet decohesion for the HIP specimens. When considering the casting pores as initial cracks, there exists a critical stress intensity threshold ranged from 1.1 to 1.3 MPam, below which fatigue cracks may not initiate from the casting pores. Furthermore, the effect of the casting pores on the fatigue limit is estimated based on a modified El Haddad model, which is in good agreement with the experimental results. Fatigue life for both the casting and HIP specimens is well predicted using the Fatigue Indicator Parameter (FIP) model. PMID:29320429
AIS/DOE Technology Roadmap Program: Strip Casting: Anticipating New Routes To Steel Sheet
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prof. Alan W. Camb; Prof. Anthony Rollett
2001-08-31
To determine the potential for strip casting in the steel industry and to develop the fundamental knowledge necessary to allow the role of strip casting in the modern steel industry to be understood. Based upon a study of carbon steel strip castings that were either produced for the program at British Steel or were received from a pre-commercial production machine, the following conclusions were made. Strip casting of carbon steels is technically feasible for sheet material from slightly less than 1 mm thick to 3 mm thick, and, assuming that it is economically viable, it will be first applied inmore » carbon steel markets that do not require stringent surface quality or extensive forming. The potential of strip casting as a casting process to be developed for steel castings is very high as the cast strip has some very novel characteristics. Direct cast carbon strip has better surface quality, shape and profile than any other casting process currently available. The more rapidly solidified structure of direct cast strip tends to be strong with low ductility; however, with adequate thermal treatment, it is possible to develop a variety of properties from the same grade. The process is more amenable at this time to production tonnages per year of the order of 500,000 tons and as such will first find niche type applications. This technology is an additional technology for steel production and will be in addition to, rather than a replacement for, current casting machines.« less
NASA Astrophysics Data System (ADS)
Narasimha Murthy, I.; Babu Rao, J.
2017-07-01
The microstructure and mechanical properties of as-cast A356 (Al-Si) alloy castings were investigated. A356 alloy was cast into three different molds composed of sand, ferrochrome (Fe-Cr) slag, and a mixture of sand and Fe-Cr. A sodium silicate-CO2 process was used to make the necessary molds. Cylindrical-shaped castings were prepared. Cast products with no porosity and a good surface finish were achieved in all of the molds. These castings were evaluated for their metallography, secondary dendrite arm spacing (SDAS), and mechanical properties, including hardness, compression, tensile, and impact properties. Furthermore, the tensile and impact samples were analyzed by fractography. The results show that faster heat transfer in the Fe-Cr slag molds than in either the silica sand or mixed molds led to lower SDAS values with a refined microstructure in the products cast in Fe-Cr slag molds. Consistent and enhanced mechanical properties were observed in the slag mold products than in the castings obtained from either sand or mixed molds. The fracture surface of the slag mold castings shows a dimple fracture morphology with a transgranular fracture nature. However, the fracture surfaces of the sand mold castings display brittle fracture. In conclusion, products cast in Fe-Cr slag molds exhibit an improved surface finish and enhanced mechanical properties compared to those of products cast in sand and mixed molds.
NASA Astrophysics Data System (ADS)
Ceschini, L.; Morri, Alessandro; Morri, Andrea
2017-05-01
The aim of this research was to investigate the effects of casting size (10-210 mm) on the microstructure and mechanical properties of spheroidal (SGI) and compacted (CGI) graphite cast irons. A comparison of the experimental mechanical data with those specified by ISO standards is presented and discussed. The study highlighted that the microstructure and mechanical properties of SGI (also known as ductile or nodular cast iron) are more sensitive to casting size than CGI (also known as vermicular graphite cast irons). In particular, in both types of cast iron, hardness, yield strength and ultimate tensile strength decreased, with increasing casting size, by 27% in SGI and 17% in CGI. Elongation to failure showed, instead, an opposite trend, decreasing from 5 to 3% in CGI, while increasing from 5 to 11% in SGI. These results were related to different microstructures, the ferritic fraction being more sensitive to the casting size in SGI than CGI. Degeneration of spheroidal graphite was observed at casting size above 120 mm. The microstructural similarities between degenerated SGI and CGI suggested the proposal of a unified empirical constitutional law relating the most important microstructural parameters to the ultimate tensile strength. An outstanding result was also the finding that standard specifications underestimated the mechanical properties of both cast irons (in particular SGI) and, moreover, did not take into account their variation with casting size, at thicknesses over 60 mm.
MicroRNAs Associated with Caste Determination and Differentiation in a Primitively Eusocial Insect
Collins, David H.; Mohorianu, Irina; Beckers, Matthew; Moulton, Vincent; Dalmay, Tamas; Bourke, Andrew F. G.
2017-01-01
In eusocial Hymenoptera (ants, bees and wasps), queen and worker adult castes typically arise via environmental influences. A fundamental challenge is to understand how a single genome can thereby produce alternative phenotypes. A powerful approach is to compare the molecular basis of caste determination and differentiation along the evolutionary trajectory between primitively and advanced eusocial species, which have, respectively, relatively undifferentiated and strongly differentiated adult castes. In the advanced eusocial honeybee, Apis mellifera, studies suggest that microRNAs (miRNAs) play an important role in the molecular basis of caste determination and differentiation. To investigate how miRNAs affect caste in eusocial evolution, we used deep sequencing and Northern blots to isolate caste-associated miRNAs in the primitively eusocial bumblebee Bombus terrestris. We found that the miRNAs Bte-miR-6001-5p and -3p are more highly expressed in queen- than in worker-destined late-instar larvae. These are the first caste-associated miRNAs from outside advanced eusocial Hymenoptera, so providing evidence for caste-associated miRNAs occurring relatively early in eusocial evolution. Moreover, we found little evidence that miRNAs previously shown to be associated with caste in A. mellifera were differentially expressed across caste pathways in B. terrestris, suggesting that, in eusocial evolution, the caste-associated role of individual miRNAs is not conserved. PMID:28361900
Novel technologies for the lost foam casting process
NASA Astrophysics Data System (ADS)
Jiang, Wenming; Fan, Zitian
2018-03-01
Lost foam casting (LFC) is a green precision casting process categorized as a near net forming technology. Yet, despite its popularity, it still suffers from some technological problems, such as poor filling ability of the castings, coarse and non-dense microstructure, low mechanical properties for the Al and Mg LFC processes, and defective carburization for the low carbon steel LFC process. These drawbacks restrict the development and widespread application of the LFC process. To solve these problems, the present study developed several novel LFC technologies, namely, LFC technologies under vacuum and low pressure, vibration solidification, and pressure solidification conditions; expendable shell casting technology; and preparation technology of bimetallic castings based on the LFC process. The results showed that the LFC under vacuum and low pressure evidently improved the filling ability and solved the oxidization problem of the alloys, which is suitable for producing complex and thinwall castings. The vibration and pressure solidifications increased the compactness of the castings and refined the microstructure, significantly improving the mechanical properties of the castings. The expendable shell casting technology could solve the pore, carburization, and inclusion defects of the traditional LFC method, obtaining castings with acceptable surface quality. Moreover, the Al/Mg and Al/Al bimetallic castings with acceptable metallurgical bonding were successfully fabricated using the LFC process. These proposed novel LFC technologies can solve the current technological issues and promote the technological progress of the LFC process.
Development of a New Membrane Casting Apparatus for Studying Macrovoid Defects in Low-G
NASA Technical Reports Server (NTRS)
Lee, Hanyong; Hwang, Sun-Tak; Krantz, William B.; Greenberg, Alan R.; Khare, Vivek; Zartman, Jeremiah; Todd, Paul W.
2002-01-01
A new membrane-casting apparatus is developed for studying macrovoid defects in polymeric membranes made by the wet- and dry-casting process in low-gravity. Macrovoids are large (10-50 micron), open cavities interspersed among the smaller pores in the substructure under the gelled skin surface layer of the cast membrane. Although their occurrence is considered endemic to the wet- and dry-casting process since they can lead to compaction or skin rupture in the membrane process, recent studies suggest several useful applications such as transdermal and osmotic drug delivery systems, miniature bioreactors, etc. However, lack of knowledge about the macrovoid formation mechanism is an obstacle to further development of applications using them. An on-going debate is the role of the surface-tension-driven solutocapillary convection during macrovoid formation. The rapid growth of macrovoids within 1-5 seconds and the high polymer concentration in and near macrovoids make it difficult to explain the mechanism of macrovoid growth by diffusion alone, which is the widely accepted hypothesis proposed by Reuvers et al. The hypothesis advanced by our research group can explain this rapid growth via a mechanism that involves diffusion from the casting solution in the meta-stable region to the macrovoid enhanced by solutocapillary convection induced by the steep nonsolvent concentration gradient in the vicinity of the macrovoid. Since macrovoid growth is hypothesized to be the interplay of a solutocapillary-induced driving force counteracted by viscous drag and buoyancy, eliminate the latter provides a means for testing this hypothesis. Moreover, free convection mass transfer in the nonsolvent immersion bath used to cause phase-separation in membrane casting complicates developing a model for both the wet-casting process and macrovoid growth. The low-g environment minimizes gravitationally induced free convection thereby permitting a tractable solution to the ternary diffusion equations that characterize membrane formation. NASA's Parabolic Flight Research Aircraft provides a small window of low-g (approximately 25 s) that can be used to study macrovoid development in both wet- and dry-cast membranes if an appropriate casting apparatus is used. This casting apparatus should be able to cast the membrane in both low- and high-g in a manner so that essential one-dimensional mass transfer conditions are achieved to insure lateral uniformity in the membrane. The apparatus used in previous research on membrane casting in low-gravity was operated with the plunger driven mechanism. The spring-loaded plunger pushes the bottom block containing the polymer casting solution well directly under the absorbent chamber located in the upper stationary block. However, membranes made via this casting apparatus often displayed lateral nonuniformities that precluded obtaining quantitative information on the macrovoid growth process. Thus, it was necessary to determine the reason for these structural irregularities observed in the low-g casting apparatus. Both experimental as well as computer simulation studies of the low-g casting apparatus established that the impulsive action of the plunger caused the undesired structural nonuniformities. The simulation results showed that the width-to-depth aspect ratio of the shallow well that contains the casting solution in this apparatus was not an important factor in minimizing this problem. Even for a 40:1 (width : depth) aspect ratio, any convection induced by the horizontal motion of the interface of the casting solution will be damped out within 6.25x10(exp 4) seconds. However, the experimental studies revealed that the impulsive motion of the plunger caused a 'sloshing' of the casting solution that had to be eliminated. Therefore, the plungerdriven mechanism was changed to a cam-driven mechanism that did not cause any impulsive motion of the casting solution. Other refinements to this new membrane-casting apparatus include provision for removing the membranes from the casting wells in a less destructive manner. This was accomplished by using a slit geometry for the casting well that permitted disassembly for removal of the cast membrane. The materials used in the construction of this casting apparatus were chosen to insure wetting at the side walls and to maintain precise control of the thickness of the polymer solution in the casting well. An additional provision in this new casting apparatus is the ability to carry out both wet- as well as dry-casting. As such, this apparatus permitted the first studies of the wet-casting of polymeric membranes in low-g. Both wet- and dry-casting experiments on NASA's KC-135 research aircraft employing this new membrane-casting apparatus are scheduled in July 2002. The morphology of the resulting membranes will be characterized using an environmental scanning electron microscope (ESEM). The results of these low-g studies will be reported later.
Cross-Validation of the Computerized Adaptive Screening Test (CAST).
ERIC Educational Resources Information Center
Pliske, Rebecca M.; And Others
The Computerized Adaptive Screening Test (CAST) was developed to provide an estimate at recruiting stations of prospects' Armed Forces Qualification Test (AFQT) scores. The CAST was designed to replace the paper-and-pencil Enlistment Screening Test (EST). The initial validation study of CAST indicated that CAST predicts AFQT at least as accurately…
McClure, Philip K; Woiczik, Marcella; Karol, Lori; Sankar, Wudbhav N
The introduction of the 80-hour work week for Accreditation Council for Graduate Medical Education (ACGME) accredited fellowship programs initiated many efforts to optimize surgical training. One particular area of interest is on recording and tracking surgical experiences. The current standard is logging cases based on Current Procedural Terminology codes, which are primarily designed for billing. Proposed guidelines from the ACGME regarding logging exist, but their implementation is unknown, as is the variation in case volume across fellowship programs. The purpose of this study was to investigate variability in the national case log data, and explore potential sources of variation using fellow surveys. National ACGME case log data for pediatric orthopaedic fellowships from 2012 to 2015 were reviewed, with particular attention to the domains of spine, pelvis/hip, arthroscopy, trauma, and other (which includes clubfoot casting). To explore potential sources of case log variability, a survey on case logging behavior was distributed to all pediatric orthopaedic fellows for the academic year 2015 to 2016. Reported experiences based on ACGME case logs varied widely between fellows with percentage difference of up to 100% in all areas. Similarly, wide variability is present in coding practices of pediatric orthopaedic fellows, who often lack formal education on the topic of appropriate coding/logging. In the survey, hypothetical case scenarios had an absolute difference in recorded codes of up to 13 and a percentage difference of up to 100%. ACGME case log data for pediatric orthopaedic fellowships demonstrates wide variability in reported surgical experiences. This variability may be due, in part, to differences in logging practices by individual fellows. This observation makes meaningful interpretation of national data on surgical volume challenging. Proposed surgical experience minimums should be interpreted in light of these data, and may not be advisable unless accompanied by standardized and specific guidelines for case log entry. Efforts to optimize training in the post 80-hour era will require accurate data to serve as a starting point for future educational efforts.
Materials for Advanced Ultrasupercritical Steam Turbines Task 4: Cast Superalloy Development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thangirala, Mani
The Steam Turbine critical stationary structural components are high integrity Large Shell and Valve Casing heavy section Castings, containing high temperature steam under high pressures. Hence to support the development of advanced materials technology for use in an AUSC steam turbine capable of operating with steam conditions of 760°C (1400°F) and 35 Mpa (5000 psia), Casting alloy selection and evaluation of mechanical, metallurgical properties and castability with robust manufacturing methods are mandated. Alloy down select from Phase 1 based on producability criteria and creep rupture properties tested by NETL-Albany and ORNL directed the consortium to investigate cast properties of Haynesmore » 282 and Haynes 263. The goals of Task 4 in Phase 2 are to understand a broader range of mechanical properties, the impact of manufacturing variables on those properties. Scale up the size of heats to production levels to facilitate the understanding of the impact of heat and component weight, on metallurgical and mechanical behavior. GE Power & Water Materials and Processes Engineering for the Phase 2, Task 4.0 Castings work, systematically designed and executed casting material property evaluation, multiple test programs. Starting from 15 lbs. cylinder castings to world’s first 17,000 lbs. poured weight, heavy section large steam turbine partial valve Haynes 282 super alloy casting. This has demonstrated scalability of the material for steam Turbine applications. Activities under Task 4.0, Investigated and characterized various mechanical properties of Cast Haynes 282 and Cast Nimonic 263. The development stages involved were: 1) Small Cast Evaluation: 4 inch diam. Haynes 282 and Nimonic 263 Cylinders. This provided effects of liquidus super heat range and first baseline mechanical data on cast versions of conventional vacuum re-melted and forged Ni based super alloys. 2) Step block castings of 300 lbs. and 600 lbs. Haynes 282 from 2 foundry heats were evaluated which demonstrated the importance of proper heat treat cycles for Homogenization, and Solutionizing parameters selection and implementation. 3) Step blocks casting of Nimonic 263: Carried out casting solidification simulation analysis, NDT inspection methods evaluation, detailed test matrix for Chemical, Tensile, LCF, stress rupture, CVN impact, hardness and J1C Fracture toughness section sensitivity data and were reported. 4) Centrifugal Casting of Haynes 282, weighing 1400 lbs. with hybrid mold (half Graphite and half Chromite sand) mold assembly was cast using compressor casing production tooling. This test provided Mold cooling rates influence on centrifugally cast microstructure and mechanical properties. Graphite mold section out performs sand mold across all temperatures for 0.2% YS; %Elongation, %RA, UTS at 1400°F. Both Stress-LMP and conditional Fracture toughness plots data were in the scatter band of the wrought alloy. 5) Fundamental Studies on Cooling rates and SDAS test program. Evaluated the influence of 6 mold materials Silica, Chromite, Alumina, Silica with Indirect Chills, Zircon and Graphite on casting solidification cooling rates. Actual Casting cooling rates through Liquidus to Solidus phase transition were measured with 3 different locations based thermocouples placed in each mold. Compared with solidification simulation cooling rates and measurement of SDAS, microstructure features were reported. The test results provided engineered casting potential methods, applicable for heavy section Haynes 282 castings for optimal properties, with foundry process methods and tools. 6) Large casting of Haynes 282 Drawings and Engineering FEM models and supplemental requirements with applicable specifications were provided to suppliers for the steam turbine proto type feature valve casing casting. Molding, melting and casting pouring completed per approved Manufacturing Process Plan during 2014 Q4. The partial valve casing was successfully cast after casting methods were validated with solidification simulation analysis and the casting met NDT inspection and acceptance criteria. Heat treated and sectioned to extract trepan samples at different locations comparing with cast on coupons test data. Material properties requisite for design, such as tensile, creep/rupture, LCF, Fracture Toughness, Charpy V-notch chemical analysis testing were carried out. The test results will be presented in the final report. The typical Haynes 282 large size Steam Turbine production casting from Order to Delivery foundry schedule with the activity break up is shown in Figures 107 and 108. • From Purchase Order placement to Casting pouring ~ 26 weeks. 1. Sales and commercial review 3 2. Engineering Drawings/models review 4 3. Pattern and core box manufacturing 6 4. Casting process engineering review 4 5. FEM and solidification simulation analysis 4 6. Gating & Feeder Attachments, Ceramic tiling 2 7. Molding and coremaking production scheduling 6 8. Melting planning and schedule 3 9. Pouring, cooling and shake out 2 • From Pouring to casting Delivery ~ 29 weeks 10. Shot blast and riser cutting, gates removal 3 11. Homogenizing , solutionizing HT furnace prep 4 12. Grinding, Fettling 2 13. Aging HT Cycle, cooling 2 14. VT and LPT NDT inspections 2 15. Radiographic inspection 4 16. Mechanical testing, Chemical analysis test certs 4 17. Casting weld repair upgrades and Aging PWHT 4 18. NDT after weld repairs and casting upgrades 3 19. Casting Final Inspection and test certifications 3 20. Package and delivery 2 Hence the Total Lead time from P.O to Casting delivery is approximately 55 weeks. The Task 4.2 and Task 4.3 activities and reporting completed.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aikin, Jr., Robert M.
This work describes the experiments and modeling that have been performed to improve and try to optimize the simultaneous casting of three plates of U-10wt%Mo in a single coil vacuum induction melting (VIM) furnace. The plates of interest are 280 mm wide by 203 mm tall by 5 mm thick (11" x 8" x 0.2"). The initial mold design and processing parameters were supplied by Y-12. The mold and casting cavity were instrumented with a number of thermocouples, and the casting performed to determine the thermal history of the mold and casting. The resulting cast plates were radiographed and numerousmore » defects identified. Metallography was performed to help identify the nature of the radiographically observed defects. This information was then used to validate a mold filling and solidification model of that casting. Based on the initial casting, good casting design practice, and process simulation of several design alternatives, a revised design was developed with the goal of minimizing casting defects such as porosity. The redesigned mold had a larger hot-top and had its long axis along the horizontal direction. These changes were to try to develop a strong thermal gradient conducive to good feeding and minimization of micro- and macroporosity in the cast plates. An instrumented casting was then performed with the revised mold design and a linear distributor. This design yielded cast plates with significantly less radiographically identified defects. Unfortunately, there was significant variation in plate weight and metal content in their hot-tops. Fluid flow simulations were then performed on this mold/distributor design. This helped identify the issue with this linear distributor design. Additional simulations were then performed on candidate distributor redesigns and a preferred distributor annular design was identified. This improved annular design was used to produce a third instrumented casting with favorable results. These refined designs and their radiographic characterization are compared to the initial design.« less
Materials processing threshold report: 2. Use of low gravity for cast iron process development
NASA Technical Reports Server (NTRS)
Frankhouser, W. L.
1980-01-01
Potential applications of a low gravity environment of interest to the commercial producers of cast iron were assessed to determine whether low gravity conditions offer potential opportunities to producers for improving cast iron properties and expanding the use of cast irons. The assessment is limited to the gray and nodular types of iron, however, the findings are applicable to all cast irons. The potential advantages accrued through low gravity experiments with cast irons are described.
Salem, Mohamed; Yao, Jianbo; Rexroad, Caird E; Kenney, P Brett; Semmens, Kenneth; Killefer, John; Nath, Joginder
2005-08-01
Calpastatin (CAST), the specific inhibitor of the calpain proteases, plays a role in muscle growth and meat quality. In rainbow trout (RBT), we identified cDNAs coding for two CAST isoforms, a long (CAST-L) and a short isoform (CAST-S), apparently derived from two different genes. Zebrafish and pufferfish CAST cDNA and genomic sequences were retrieved from GenBank and their exon/intron structures were characterized. Fish CASTs are novel in that they have fewer repetitive inhibitory domains as compared to their mammalian counterparts (one or two vs. four). The expressions of CAST mRNAs were measured in three RBT strains with different growth rates and fillet firmness that were fed either high energy or control diets. CAST-L and S expressions were significantly lower (p<0.01) in the strain that has the slowest growth rate and yielded the softest fillet. Strain or diet did not affect level of calpain mRNAs. However, the decrease in the CAST/calpain ratio at the mRNA level did not lead to a corresponding change in the calpain catalytic activity. Further investigation should reveal a potential use of the CAST gene as a tool to monitor fish muscle growth and fillet firmness.
Chemical-Gene Interactions from ToxCast Bioactivity Data ...
Characterizing the effects of chemicals in biological systems is often summarized by chemical-gene interactions, which have sparse coverage in the literature. The ToxCast chemical screening program has produced bioactivity data for nearly 2000 chemicals and over 450 gene targets. To evaluate the information gained from the ToxCast project, a ToxCast bioactivity network was created comprising ToxCast chemical-gene interactions based on assay data and compared to a chemical-gene association network from literature. The literature network was compiled from PubMed articles, excluding ToxCast publications, mapped to genes and chemicals. Genes were identified by curated associations available from NCBI while chemicals were identified by PubChem submissions. The frequencies of chemical-gene associations from the literature network were log-scaled and then compared to the ToxCast bioactivity network. In total, 140 times more chemical-gene associations were present in the ToxCast network in comparison to the literature-derived network highlighting the vast increase in chemical-gene interactions putatively elucidated by the ToxCast research program. There were 165 associations found in the literature network that were reproduced by ToxCast bioactivity data, and 336 associations in the literature network were not reproduced by the ToxCast bioactivity network. The literature network relies on the assumption that chemical-gene associations represent a true chemical-gene inte
Nogueira, Renato Luiz Maia; Osterne, Rafael Lima Verde; Abreu, Ricardo Teixeira; Araújo, Phelype Maia
2017-07-01
An alternative technique to reconstruct atrophic alveolar vertical bone after implant placement is presented. The technique consists of distraction osteogenesis or direct surgical repositioning of an implant-and-bone block segment after segmental osteotomies that can be used in esthetic or unesthetic cases. Initially, casts indicating the implant position are obtained and the future ideal prosthetic position is determined to guide the model surgery. After the model surgery, a new provisional prosthesis is fabricated, and an occlusal splint, which is used as a surgical guide and a device for distraction osteogenesis, is custom fabricated. Then, the surgery is performed. For mobilization of the implant-and-bone block segment, 2 vertical osteotomies are performed and then joined by a horizontal osteotomy. The implant-and-bone block segment is moved to the planned position. If a small movement is planned, then the implant-and-bone segment is stabilized; for larger movements, the implant-and-bone segment can be gradually moved to the final position by distraction osteogenesis. This technique has good predictability of the final position of the implant-and-bone segment and relatively fast esthetic rehabilitation. It can be considered for dental implants in regions of vertical bone atrophy. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Hashemi, Sepehr; Armand, Mehran; Gordon, Chad R
2016-10-01
To describe the development and refinement of the computer-assisted planning and execution (CAPE) system for use in face-jaw-teeth transplants (FJTTs). Although successful, some maxillofacial transplants result in suboptimal hybrid occlusion and may require subsequent surgical orthognathic revisions. Unfortunately, the use of traditional dental casts and splints pose several compromising shortcomings in the context of FJTT and hybrid occlusion. Computer-assisted surgery may overcome these challenges. Therefore, the use of computer-assisted orthognathic techniques and functional planning may prevent the need for such revisions and improve facial-skeletal outcomes. A comprehensive CAPE system for use in FJTT was developed through a multicenter collaboration and refined using plastic models, live miniature swine surgery, and human cadaver models. The system marries preoperative surgical planning and intraoperative execution by allowing on-table navigation of the donor fragment relative to recipient cranium, and real-time reporting of patient's cephalometric measurements relative to a desired dental-skeletal outcome. FJTTs using live-animal and cadaveric models demonstrate the CAPE system to be accurate in navigation and beneficial in improving hybrid occlusion and other craniofacial outcomes. Future refinement of the CAPE system includes integration of more commonly performed orthognathic/maxillofacial procedures.
... Kinds of Casts? Most casts are made of fiberglass. Fiberglass is a kind of plastic that can be ... to the body part. It dries hard. Some fiberglass casts are waterproof. Doctors only use this type ...
Casting for infantile scoliosis: the pitfall of increased peak inspiratory pressure.
Dhawale, Arjun A; Shah, Suken A; Reichard, Samantha; Holmes, Laurens; Brislin, Robert; Rogers, Kenneth; Mackenzie, William G
2013-01-01
Serial cast correction is a popular treatment option for progressive infantile scoliosis. Body casting can lead to chest and abdominal expansion restriction and result in decreased chest wall compliance. There are no studies evaluating the effects of casting on ventilation in infantile scoliosis. This study examines changes in peak inspiratory pressure (PIP) during serial casting for infantile scoliosis. We retrospectively reviewed data obtained from 37 serial Cotrel elongation, derotation, and flexion cast corrections in patients with infantile scoliosis. Patient demographics, radiographic measurements, and anesthesia data were recorded. Anesthesia technique was standardized: children were intubated with rigid endotracheal tubes (ETTs); tidal volume was held constant at 8 to 10 cm(3)/kg using volume control ventilation; and PIP was recorded at baseline, after cast application before window cutout, and after window cutout before extubation. Any complications were documented. We assessed the PIP changes with a repeated measures analysis of variance (ANOVA). The mean age at first casting was 21.8 months (range, 12 to 42 mo) and mean follow-up since first casting was 22.4 months (range, 13 to 40 mo) with mean major Cobb angle of 53±15 degrees. The mean PIP was 15.5±4.9 cm H(2)O before casting, 31.9±7.9 cm H(2)O after cast application, and 20.4±5.6 cm H2O after making windows. There was a 106% increase after casting and 32% increase after window cutout from the baseline PIP levels. There was a significant difference in PIP on repeated measures ANOVA (P<0.0001). Intraoperatively, there was difficulty in maintaining ventilation during 2 procedures and 1 hypotensive episode. One patient developed hypoxemia after casting and another had delayed difficulty in breathing. Casting resulted in an increased PIP due to transient restrictive pulmonary process; after windows were cut out, the PIP reduced but not to baseline. In patients with underlying pulmonary disease, the casting process may induce respiratory complications, and a proper period of observation after casting is necessary. Case series, level 4.
GRINDING ROOM AT SOUTHERN DUCTILE CASTING COMPANY, BESSEMER FOUNDRY SHOWING ...
GRINDING ROOM AT SOUTHERN DUCTILE CASTING COMPANY, BESSEMER FOUNDRY SHOWING WHEELABORATOR THAT IMPALE SHOT AT TUMBLING CASTINGS TO REMOVE EXCESS SURFACE METALS AND SAND; ANNEALING OVENS TO HEAT CERTAIN CASTINGS TO ACHIEVE A DESIRED CHARACTERISTIC; AND GRINDING WHEELS USED TO REMOVE GATES. - Southern Ductile Casting Company, Grinding & Shipping, 2217 Carolina Avenue, Bessemer, Jefferson County, AL
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cast cover. 880.6185 Section 880.6185 Food and....6185 Cast cover. (a) Identification. A cast cover is a device intended for medical purposes that is made of waterproof material and placed over a cast to protect it from getting wet during a shower or a...
Botulinum Toxin Treatment for Limb Spasticity in Childhood Cerebral Palsy
Pavone, Vito; Testa, Gianluca; Restivo, Domenico A.; Cannavò, Luca; Condorelli, Giuseppe; Portinaro, Nicola M.; Sessa, Giuseppe
2016-01-01
CP is the most common cause of chronic disability in childhood occurring in 2–2.5/1000 births. It is a severe disorder and a significant number of patients present cognitive delay and difficulty in walking. The use of botulinum toxin (BTX) has become a popular treatment for CP especially for spastic and dystonic muscles while avoiding deformity and pain. Moreover, the combination of physiotherapy, casting, orthotics and injection of BTX may delay or decrease the need for surgical intervention while reserving single-event, multi-level surgery for fixed musculotendinous contractures and bony deformities in older children. This report highlights the utility of BTX in the treatment of cerebral palsy in children. We include techniques for administration, side effects, and possible resistance as well as specific use in the upper and lower limbs muscles. PMID:26924985
Treatment of posttraumatic deformities in the radiocarpal joint in children.
Doletsky, S J; Kiselev, V P
1979-01-01
Experience with treatment of 1885 children with fracture of the forearm bones is reported. Almost 1/3 (28.1%) were patients with epi-osteoepiphysiolysis of the distal end of the radius. In the majority, the method of treatment was conservative: closed manual reposition and immobilization with plaster cast during 3-4 weeks. Closed one-stage reposition is effective only during the first hours of 2-3 days after the trauma. The deformity following an inveterate epi-osteoepiphysiolysis must be corrected surgically before the physiological closure of the growth zones. The pathogenetic problems of posttraumatic deformities in the radiocarpal articulation are discussed and attention is focussed on the "admissible" types of displacement of the epiphysis (meta-epiphysis). The method of bloodless correction of deformities by means of distraction apparatuses is described. The technique was performed in 41 children with good results.
Kofler, J; Peterbauer, C
2014-01-01
This case report describes the clinical and radiographic findings and the surgical treatment of a serofibrinous arthritis of the antebrachiocarpal joint and of a chronic purulent arthritis of the intercarpal and carpometacarpal joints with osteomyelitis of the distal carpal bones and subchondral osteomyelitis of the proximal metacarpal bones in a cow of the breed "Pustertaler Sprinze". The therapy comprised an arthrotomy of both joint spaces and the resection of the distal row of the carpal bones. The right forelimb had been immobilised for 70 days by a full limb cast. After this period, radiographs revealed an ob- vious ankylosis of the carpal joint, and the cow showed only a slight lameness. Six years postoperatively this cow was still in the herd and had produced six calves.
Acute closed radial nerve injury
Tuncel, Umut; Turan, Aydin; Kostakoglu, Naci
2011-01-01
We present a 45-year-old patient who had acute radial nerve palsy following a blunt trauma without any fracture or dislocation. He was injured by strucking in a combat three months ago. The patient has been followed by application of a long-arm plaster cast before referred to our clinic. Preoperative electromyoneurography and magnetic resonance imaging (MRI) indicated that there was a radial nerve injury on humeral groove. The British Medical Research Council (MRC) grade was 2/5 on his wrist preoperatively. The patient underwent an operation under general anesthesia. It was seen to be a second-degree nerve injury. The patient has subsequently regained full movement on his wrist and finger extension in six months. We suggest that a detailed clinical and electrodiagnostical evaluation is necessary in patients who have radial nerve injury when deciding the treatment, conservative or surgical. PMID:22347334
Botulinum Toxin Treatment for Limb Spasticity in Childhood Cerebral Palsy.
Pavone, Vito; Testa, Gianluca; Restivo, Domenico A; Cannavò, Luca; Condorelli, Giuseppe; Portinaro, Nicola M; Sessa, Giuseppe
2016-01-01
CP is the most common cause of chronic disability in childhood occurring in 2-2.5/1000 births. It is a severe disorder and a significant number of patients present cognitive delay and difficulty in walking. The use of botulinum toxin (BTX) has become a popular treatment for CP especially for spastic and dystonic muscles while avoiding deformity and pain. Moreover, the combination of physiotherapy, casting, orthotics and injection of BTX may delay or decrease the need for surgical intervention while reserving single-event, multi-level surgery for fixed musculotendinous contractures and bony deformities in older children. This report highlights the utility of BTX in the treatment of cerebral palsy in children. We include techniques for administration, side effects, and possible resistance as well as specific use in the upper and lower limbs muscles.
Processing of IN-718 Lattice Block Castings
NASA Technical Reports Server (NTRS)
Hebsur, Mohan G.
2002-01-01
Recently a low cost casting method known as lattice block casting has been developed by JAM Corporation, Wilmington, Massachusetts for engineering materials such as aluminum and stainless steels that has shown to provide very high stiffness and strength with only a fraction of density of the alloy. NASA Glenn Research Center has initiated research to investigate lattice block castings of high temperature Ni-base superalloys such as the model system Inconel-718 (IN-718) for lightweight nozzle applications. Although difficulties were encountered throughout the manufacturing process , a successful investment casting procedure was eventually developed. Wax formulation and pattern assembly, shell mold processing, and counter gravity casting techniques were developed. Ten IN-718 lattice block castings (each measuring 15-cm wide by 30-cm long by 1.2-cm thick) have been successfully produced by Hitchiner Gas Turbine Division, Milford, New Hampshire, using their patented counter gravity casting techniques. Details of the processing and resulting microstructures are discussed in this paper. Post casting processing and evaluation of system specific mechanical properties of these specimens are in progress.
Research on the influence of moulding-casting technology on the quality of castings
NASA Astrophysics Data System (ADS)
Josan, A.; Pinca Bretotean, C.; Raţiu, S.; Ardelean, E.; Ardelean, M.
2017-05-01
The quality of castings has a particularly role in the Romanian foundries. In this context, quality assurance is the overall objective of the foundries. The paper presents the critical analysis performed on moulding-casting technology of the type Lifting mechanism. This casting is a subset of the lifting and rotating mechanism of the furnace vault. The casting analysed is a medium size, with weight of 114 kg. The current moulding-casting technology involves moulding into three mould-parts leading to the occurrence of defects (decentering of the core, displacement of the lower mould and the middle mould and occurrence of burrs in area separated. Thus, to reduce the percentage of defects registered in industrial practice is necessary to change the moulding-casting technology. This requires the use of two mould-parts, re-dimensioning of the core and the core box and dimensioning of the runner network. The adoption of these changes in industrial practice has direct implications on the cost of casting and foundry costs default.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karimian, Majid; Idris, M. H.; Ourdjini, A.
2011-01-17
The paper presents the result of an experimental investigation conducted on medium aluminum silicon alloy casting- LM6, using no-vacuum assisted lost foam casting process. The study is directed for establishing the relationship between the flask vibrations times developed for molded sample on the casting integrity, surface penetration and coating inclusion defects of the casting. Four different flask vibration times namely 180, 120, 90 and 60 sec. were investigated. The casting integrity was investigated in terms of fulfilling in all portions and edges. The surface penetration was measured using optical microscope whilst image analyzer was used to quantify the percentage ofmore » coating inclusion in the casting. The results show that vibration time has significant influence on the fulfilling as well as the internal integrity of the lost foam casting. It was found that the lower vibration time produced comparatively sound casing.« less
Pneumatic gap sensor and method
Bagdal, Karl T.; King, Edward L.; Follstaedt, Donald W.
1992-01-01
An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment.
Pneumatic gap sensor and method
Bagdal, K.T.; King, E.L.; Follstaedt, D.W.
1992-03-03
An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment. 6 figs.
Energy Saving Melting and Revert Reduction (E-SMARRT): Precision Casting of Steel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dr. Von L. Richards
2011-09-30
This project addresses improvements in metal casting processes by reducing scrap and reducing the cost of production, due to scrap reduction from investment casting and yield improvement offered by lost foam casting as compared to no-bake or green sand molding. The objectives for the investment casting portion of the subtask are to improve knowledge of fracture toughness of mold shells and the sources of strength limiting flaws and to understand the effects of wax reclamation procedures on wax properties. Applying 'clean steel' approaches to pouring technology and cleanliness in investment casting of steel are anticipated to improve incoming materials inspectionmore » procedures as they affect the microstructure and toughness of the shell. This project focused on two areas of study in the production of steel castings to reduce scrap and save energy: (1) Reducing the amount of shell cracking in investment cast steel production; (2) Investigate the potential of lost foam steel casting The basic findings regarding investment casting shell cracking were: (1) In the case of post pouring cracking, this could be related to phase changes in silica upon cooling and could be delayed by pouring arrangement strategies that maintained the shell surface at temperature for longer time. Employing this delay resulted in less adherent oxidation of castings since the casting was cooler at the time o fair exposure. (2) A model for heat transfer through water saturated shell materials under steam pressure was developed. (3) Initial modeling result of autoclave de-waxing indicated the higher pressure and temperature in the autoclave would impose a steeper temperature gradient on the wax pattern, causing some melt flow prior to bulk expansion and decreasing the stress on the green shell. Basic findings regarding lost foam casting of steel at atmospheric pressure: (1) EPS foam generally decomposes by the collapse mode in steel casting. (2) There is an accumulation of carbon pick-up at the end of the casting opposite the gate. (3) It is recommended that lost foam castings in steel be gated for a quiescent fill in an empty cavity mold to prevent foam occlusion defects from the collapse mode. The energy benefit is primarily in yield savings and lower casting weight per function due to elimination of draft and parting lines for the larger lost foam castings. For the smaller investment casting, scrap losses due to shell cracking will be reduced. Both of these effects will reduce the metal melted per good ton of castings. There will also be less machine stock required per casting which is a yield savings and a small additional energy savings in machining. Downstream savings will come from heavy truck and railroad applications. Application of these processes to heavy truck castings will lighten the heavy truck fleet by about ten pounds per truck. Using ten years to achieve full penetration of the truck fleet at linear rate this will result in a fuel savings of 131 trillion BTU over ten years.« less
[Class III surgical patients facilitated by accelerated osteogenic orthodontic treatment].
Wu, Jia-qi; Xu, Li; Liang, Cheng; Zou, Wei; Bai, Yun-yang; Jiang, Jiu-hui
2013-10-01
To evaluate the treatment time and the anterior and posterior teeth movement pattern as closing extraction space for the Class III surgical patients facilitated by accelerated osteogenic orthodontic treatment. There were 10 skeletal Class III patients in accelerated osteogenic orthodontic group (AOO) and 10 patients in control group. Upper first premolars were extracted in all patients. After leveling and alignment (T2), corticotomy was performed in the area of maxillary anterior teeth to accelerate space closing.Study models of upper dentition were taken before orthodontic treatment (T1) and after space closing (T3). All the casts were laser scanned, and the distances of the movement of incisors and molars were digitally measured. The distances of tooth movement in two groups were recorded and analyzed. The alignment time between two groups was not statistically significant. The treatment time in AOO group from T2 to T3 was less than that in the control group (less than 9.1 ± 4.1 months). The treatment time in AOO group from T1 to T3 was less than that in the control group (less than 6.3 ± 4.8 months), and the differences were significant (P < 0.01). Average distances of upper incisor movement (D1) in AOO group and control group were (2.89 ± 1.48) and (3.10 ± 0.95) mm, respectively. Average distances of upper first molar movement (D2) in AOO group and control group were (2.17 ± 1.13) and (2.45 ± 1.04) mm, respectively.No statistically significant difference was found between the two groups (P > 0.05). Accelerated osteogenic orthodontic treatment could accelerate space closing in Class III surgical patients and shorten preoperative orthodontic time. There were no influence on the movement pattern of anterior and posterior teeth during pre-surgical orthodontic treatment.
Stehmann, Tijs A; Goudriaan, W A Alexander; In 't Veen, J C C M Hans; Kollen, Boudewijn J; Verheyen, C C P M Kees
2016-01-01
To describe the number of ratings and the corresponding scores given to medical specialists on the Dutch healthcare assessment website 'Zorgkaart Nederland.nl', and evaluation of this website as tool for evaluation of quality. Explorative descriptive study. In July 2015, data were gathered from the public section of the healthcare assessment website 'ZorgkaartNederland.nl'. The number of specialists, the mean ratings per department (group mark), the number of evaluations, the number of medical specialists without a rating and the number of specialists with at least 9 ratings were registered per speciality, per hospital. Outcomes measures were the median number of ratings per speciality and the group score. Data were analysed using descriptive and non-parametric statistics. Each month, 763,000 unique visitors access ZorgkaartNederland.nl; on average, 0.08% of these registers a vote. There were 15,337 medical specialists, spread across 97 hospitals and 2,060 specialities on ZorgkaartNederland.nl, with a total of 45,548 evaluations. Of these, 6,682 (43.4%) specialists were not rated, and 1.165 (7.6%) had ≥ 9 ratings. Additionally, 327 (15.9%) departments were unrated. Surgical departments were evaluated more often, and their grades were significantly higher, than those of non-surgical departments. The website ZorgkaartNederland.nl shows ratings for 56.6% of all medical specialists. When the lower limit of at least 9 evaluations per specialist introduced by ZorgkaartNederland.nl was applied, only the grades for 7.6% of all specialists are valid. On average, 0.08% of unique visitors cast a vote. Surgical specialities have a higher number of evaluations and a higher score than non-surgical ones. ZorgkaartNederland.nl in its current form does not constitute a valid tool for evaluation of the quality of medical specialist care in the Netherlands. This article provides recommendations for improvement.
Ye, Hongqiang; Ma, Qijun; Hou, Yuezhong; Li, Man; Zhou, Yongsheng
2017-12-01
Digital techniques are not clinically applied for 1-piece maxillary prostheses containing an obturator and removable partial denture retained by the remaining teeth because of the difficulty in obtaining sufficiently accurate 3-dimensional (3D) images. The purpose of this pilot clinical study was to generate 3D digital casts of maxillary defects, including the defective region and the maxillary dentition, based on multisource data registration and to evaluate their effectiveness. Twelve participants with maxillary defects were selected. The maxillofacial region was scanned with spiral computer tomography (CT), and the maxillary arch and palate were scanned using an intraoral optical scanner. The 3D images from the CT and intraoral scanner were registered and merged to form a 3D digital cast of the maxillary defect containing the anatomic structures needed for the maxillary prosthesis. This included the defect cavity, maxillary dentition, and palate. Traditional silicone impressions were also made, and stone casts were poured. The accuracy of the digital cast in comparison with that of the stone cast was evaluated by measuring the distance between 4 anatomic landmarks. Differences and consistencies were assessed using paired Student t tests and the intraclass correlation coefficient (ICC). In 3 participants, physical resin casts were produced by rapid prototyping from digital casts. Based on the resin casts, maxillary prostheses were fabricated by using conventional methods and then evaluated in the participants to assess the clinical applicability of the digital casts. Digital casts of the maxillary defects were generated and contained all the anatomic details needed for the maxillary prosthesis. Comparing the digital and stone casts, a paired Student t test indicated that differences in the linear distances between landmarks were not statistically significant (P>.05). High ICC values (0.977 to 0.998) for the interlandmark distances further indicated the high degree of consistency between the digital and stone casts. The maxillary prostheses showed good clinical effectiveness, indicating that the corresponding digital casts met the requirements for clinical application. Based on multisource data from spiral CT and the intraoral scanner, 3D digital casts of maxillary defects were generated using the registration technique. These casts were consistent with conventional stone casts in terms of accuracy and were suitable for clinical use. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Yan, Min; Takahashi, Hidekazu; Nishimura, Fumio
2004-12-01
The aim of the present study was to evaluate the dimensional accuracy and surface property of titanium casting obtained using a gypsum-bonded alumina investment. The experimental gypsum-bonded alumina investment with 20 mass% gypsum content mixed with 2 mass% potassium sulfate was used for five cp titanium castings and three Cu-Zn alloy castings. The accuracy, surface roughness (Ra), and reaction layer thickness of these castings were investigated. The accuracy of the castings obtained from the experimental investment ranged from -0.04 to 0.23%, while surface roughness (Ra) ranged from 7.6 to 10.3microm. A reaction layer of about 150 microm thickness under the titanium casting surface was observed. These results suggested that the titanium casting obtained using the experimental investment was acceptable. Although the reaction layer was thin, surface roughness should be improved.
An investigation of squeeze-cast alloy 718
NASA Technical Reports Server (NTRS)
Gamwell, W. R.
1993-01-01
Alloy 718 billets produced by the squeeze-cast process have been evaluated for use as potential replacements for propulsion engine components which are normally produced from forgings. Alloy 718 billets were produced using various processing conditions. Structural characterizations were performed on 'as-cast' billets. As-cast billets were then homogenized and solution treated and aged according to conventional heat-treatment practices for this alloy. Mechanical property evaluations were performed on heat-treated billets. As-cast macrostructures and microstructures varied with squeeze-cast processing parameters. Mechanical properties varied with squeeze-cast processing parameters and heat treatments. One billet exhibited a defect free, refined microstructure, with mechanical properties approaching those of wrought alloy 718 bar, confirming the feasibility of squeeze-casting alloy 718. However, further process optimization is required, and further structural and mechanical property improvements are expected with process optimization.
The efficiencies of cast blasting in wide pits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, R.L.; King, M.G.
Blasting activities in all four pits at Thunder Basin Coal`s Black Thunder Mine are focused on cast blasting. With widths varying from 190 feet to 265 feet and bench heights varying from 90 feet to 175 feet, casting efficiencies vary with different geometry`s. For example, the percent cast to final in the 200 foot pit is on the average higher than the 270 foot pit. The powder factors are somewhat higher in the narrower pits, thus increasing the cost of blasting. This leads to a very detailed look at the actual benefit of cast blasting and the associated cost ofmore » these benefits. The simple solution would be to reduce the width of the pits, thereby increasing the percent cast to final. However, the lower rehandle and low coal loss associated with wide pits would be fortified. Upon further review it becomes obvious that the wider pits could not be compared to the narrow pits with the cast to final percent indices. The focus should be shifted to cubic yards cast to final per lineal foot of pit. This will allow for more accurate measures of the casting efficiency of the shot. When comparing the pits with these indices their performances were much closer than the percent cast to final indices. The powder factors being higher in the narrow pits drove up the cost per cubic yard cast to final. Therefore, even though the percent cast to final was higher, the cost per cubic yard was also higher.« less
Memon, Sarfaraz
2014-12-01
A stable centric occlusal position that shows no evidence of occlusal disease should not be altered. Confirmative restorative dentistry deals with making restorations that are in harmony with existing jaw relations. Conventional techniques for construction have been unsuccessful in producing a prosthesis that can be inserted without minor intraoral occlusal adjustment. This study was conducted to evaluate the benefits of the double casting technique with FGP over the conventional casting technique. Ten patients with root canal treated maxillary molar were selected for the fabrication of metal crown. Two techniques, one involving the conventional fabrication and other using functionally generated path with double casting were used to fabricate the prosthesis. A comparison based on various parameters which was done between the two techniques. The change in the height of castings for the double casting group was less compared to the conventional group and was highly statistically significant (P < 0.001). The time taken for occlusal correction was significantly lower in double casting group than the conventional group (P < 0.001). The patient satisfaction (before occlusal correction) indicated better satisfaction for double casting group compared to conventional (P < 0.01). The functionally generated path with double casting technique resulted in castings which had better dimensional accuracy, less occlusal correction and better patient satisfaction compared to the conventional castings.
Hossler, Fred E.; Douglas, John E.
2001-05-01
Vascular corrosion casting has been used for about 40 years to produce replicas of normal and abnormal vasculature and microvasculature of various tissues and organs that could be viewed at the ultrastructural level. In combination with scanning electron microscopy (SEM), the primary application of corrosion casting has been to describe the morphology and anatomical distribution of blood vessels in these tissues. However, such replicas should also contain quantitative information about that vasculature. This report summarizes some simple quantitative applications of vascular corrosion casting. Casts were prepared by infusing Mercox resin or diluted Mercox resin into the vasculature. Surrounding tissues were removed with KOH, hot water, and formic acid, and the resulting dried casts were observed with routine SEM. The orientation, size, and frequency of vascular endothelial cells were determined from endothelial nuclear imprints on various cast surfaces. Vascular volumes of heart, lung, and avian salt gland were calculated using tissue and resin densities, and weights. Changes in vascular volume and functional capillary density in an experimentally induced emphysema model were estimated from confocal images of casts. Clearly, corrosion casts lend themselves to quantitative analysis. However, because blood vessels differ in their compliances, in their responses to the toxicity of casting resins, and in their response to varying conditions of corrosion casting procedures, it is prudent to use care in interpreting this quantitative data. Some of the applications and limitations of quantitative methodology with corrosion casts are reviewed here.
Investigation of Materials Processing Technology
1993-07-01
Figure 6: Time-temperature curves of A357 casting in Cu mold ................. 12 Figure 7: Time-temperature curves of 17 -4 casting in ceramic mold...simulation of 17 -4 ................ 17 Figure 12: IHTC from IHEAT simulation of 17 -4 casting ..................... 18 Figure 13: Temperature profiles...mold used for Ti castings .......................... 23 Figure 16: Cooling curves for a Ti casting in ceramic mold .................. 24 Figure 17
49 CFR 192.373 - Service lines: Cast iron and ductile iron.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 3 2010-10-01 2010-10-01 false Service lines: Cast iron and ductile iron. 192.373... Regulators, and Service Lines § 192.373 Service lines: Cast iron and ductile iron. (a) Cast or ductile iron... cast iron pipe or ductile iron pipe is installed for use as a service line, the part of the service...
Hot forging of roll-cast high aluminum content magnesium alloys
NASA Astrophysics Data System (ADS)
Kishi, Tomohiro; Watari, Hisaki; Suzuki, Mayumi; Haga, Toshio
2017-10-01
This paper reports on hot forging of high aluminum content magnesium alloy sheets manufactured using horizontal twin-roll casting. AZ111 and AZ131 were applied for twin-roll casting, and a hot-forging test was performed to manufacture high-strength magnesium alloy components economically. For twin-roll casting, the casting conditions of a thick sheet for hot forging were investigated. It was found that twin-roll casting of a 10mm-thick magnesium alloy sheet was possible at a roll speed of 2.5m/min. The grain size of the cast strip was 50 to 70µm. In the hot-forging test, blank material was obtained from as-cast strip. A servo press machine with a servo die cushion was used to investigate appropriate forging conditions (e.g., temperature, forging load, and back pressure) for twin-roll casts (TRCs) AZ111 and AZ131. It was determined that high aluminum content magnesium alloy sheets manufactured using twin-roll casting could be forged with a forging load of 150t and a back pressure of 3t at 420 to 430°C. Applying back pressure during hot forging effectively forged a pin-shaped product.
Zhou, Qin; Wang, Zhenzhen; Chen, Jun; Song, Jun; Chen, Lu; Lu, Yi
2016-01-01
For reasons of convenience and economy, attempts have been made to transform traditional dental gypsum casts into 3-dimensional (3D) digital casts. Different scanning devices have been developed to generate digital casts; however, each has its own limitations and disadvantages. The purpose of this study was to develop an advanced method for the 3D reproduction of dental casts by using a high-speed grating projection system and noncontact reverse engineering (RE) software and to evaluate the accuracy of the method. The methods consisted of 3 main steps: the scanning and acquisition of 3D dental cast data with a high-resolution grating projection system, the reconstruction and measurement of digital casts with RE software, and the evaluation of the accuracy of this method using 20 dental gypsum casts. The common anatomic landmarks were measured directly on the gypsum casts with a Vernier caliper and on the 3D digital casts with the Geomagic software measurement tool. Data were statistically assessed with the t test. The grating projection system had a rapid scanning speed, and smooth 3D dental casts were obtained. The mean differences between the gypsum and 3D measurements were approximately 0.05 mm, and no statistically significant differences were found between the 2 methods (P>.05), except for the measurements of the incisor tooth width and maxillary arch length. A method for the 3D reconstruction of dental casts was developed by using a grating projection system and RE software. The accuracy of the casts generated using the grating projection system was comparable with that of the gypsum casts. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Focused Molding Using Adhesive Pads in Mehta Casting for Early-Onset Scoliosis.
Abraham, Roby; Sponseller, Paul D
2014-11-01
Prospective clinical series. To determine the effect of adhesive pads placed over the apex of scoliosis curves on curve correction 1) after the first cast and 2) after the final cast. Early-onset scoliosis is often effectively managed by serial casting. Properly localizing the apex of the molds with the cast in place is challenging. The authors explored the effectiveness of a novel technique: incorporation of adhesive pads placed over the major curve apex before Mehta casting. The 27 patients who received body casts (2000-2013) were divided into 2 groups: those without and with apical adhesive pads (5-6 layers of pads placed on the major curve's apex during casting): non-pad (NP) group (n = 12) and pad (P) group (n = 15), respectively. Groups were compared regarding the percentage of Cobb angle change from the first cast and curve correction to a Cobb angle of <25° with Student t and chi-square tests (significance was p < .05). The mean percentage of major first-cast curve correction was 39% ± 18% and 56% ± 17% in the NP and P groups, respectively. Of the 26 patients out of a cast, 11 (42%) had a Cobb angle of <25°: 3 (25%) and 8 (57%) in the NP and P groups, respectively. The mean differences between the 2 groups in percentage of major curve correction and this Cobb angle correction were significant: p = .023 and .005, respectively. Adhesive pads placed over major curve(s) during Mehta casting were effective in increasing the amount of major curve correction from the first cast for idiopathic early-onset scoliosis and in decreasing curves to <25° at final follow-up. Copyright © 2014 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.
Hajiaghaei, Behnam; Ebrahimi, Ismail; Kamyab, Mojtaba; Saeedi, Hassan; Jalali, Maryam
2016-01-01
Creating a socket with proper fit is an important factor to ensure the comfort and control of prosthetic devices. Several techniques are commonly used to cast transtibial stumps but their effect on stump shape deformation is not well understood. This study compares the dimensions, circumferences and volumes of the positive casts and also the socket comfort between two casting methods. Our hypothesis was that the casts prepared by air pressure method have less volume and are more comfortable than those prepared by weight bearing method. Fifteen transtibial unilateral amputees participated in the study. Two weight bearing and air pressure casting methods were utilized for their residual limbs. The diameters and circumferences of various areas of the residual limbs and positive casts were compared. The volumes of two types of casts were measured by a volumeter and compared. Visual Analogue Scale (VAS) was used to measure the sockets fit comfort. Circumferences at 10 and 15 cm below the patella on the casts were significantly smaller in air pressure casting method compared to the weight bearing method (p=0.00 and 0.01 respectively). The volume of the cast in air pressure method was lower than that of the weight bearing method (p=0.006). The amputees found the fit of the sockets prepared by air pressure method more comfortable than the weight bearing sockets (p=0.015). The air pressure casting reduced the circumferences of the distal portion of residual limbs which has more soft tissue and because of its snug fit it provided more comfort for amputees, according to the VAS measurements.
NASA Astrophysics Data System (ADS)
Brown, Lloyd; Joyce, Peter; Radice, Joshua; Gregorian, Dro; Gobble, Michael
2012-07-01
Strain rate dependency of mechanical properties of tungsten carbide (WC)-filled bronze castings fabricated by centrifugal and sedimentation-casting techniques are examined, in this study. Both casting techniques are an attempt to produce a functionally graded material with high wear resistance at a chosen surface. Potential applications of such materials include shaft bushings, electrical contact surfaces, and brake rotors. Knowledge of strain rate-dependent mechanical properties is recommended for predicting component response due to dynamic loading or impact events. A brief overview of the casting techniques for the materials considered in this study is followed by an explanation of the test matrix and testing techniques. Hardness testing, density measurement, and determination of the volume fraction of WC particles are performed throughout the castings using both image analysis and optical microscopy. The effects of particle filling on mechanical properties are first evaluated through a microhardness survey of the castings. The volume fraction of WC particles is validated using a thorough density survey and a rule-of-mixtures model. Split Hopkinson Pressure Bar (SHPB) testing of various volume fraction specimens is conducted to determine strain dependence of mechanical properties and to compare the process-property relationships between the two casting techniques. The baseline performances of C95400 bronze are provided for comparison. The results show that the addition of WC particles improves microhardness significantly for the centrifugally cast specimens, and, to a lesser extent, in the sedimentation-cast specimens, largely because the WC particles are more concentrated as a result of the centrifugal-casting process. Both metal matrix composites (MMCs) demonstrate strain rate dependency, with sedimentation casting having a greater, but variable, effects on material response. This difference is attributed to legacy effects from the casting process, namely, porosity and localized WC particle grouping.
Precision cast vs. wrought superalloys
NASA Technical Reports Server (NTRS)
Tien, J. K.; Borofka, J. C.; Casey, M. E.
1986-01-01
While cast polycrystalline superalloys recommend themselves in virtue of better 'buy-to-fly' ratios and higher strengthening gamma-prime volume fractions than those of wrought superalloys, the expansion of their use into such critical superalloy applications as gas turbine hot section components has been slowed by insufficient casting process opportunities for microstructural control. Attention is presently drawn, however, to casting process developments facilitating the production of defect-tolerant superalloy castings having improved fracture reliability. Integrally bladed turbine wheel and thin-walled turbine exhaust case near-net-shape castings have been produced by these means.
Casting of Ti-6Al-4V alloy compared with pure Ti in an Ar-arc casting machine.
Syverud, M; Okabe, T; Herø, H
1995-10-01
Dental prostheses of Ti are normally cast in pure Ti. Some appliances, however, require higher yield strength. Casting of Ti alloys is of interest in such cases. The objective of the present work was to study the quality of castings made of Ti-6Al-4V compared with those made of pure Ti. Casting was made into a mold kept at room temperature using a MgO-Al2O3 investment. A standardized five-unit bridge was cast, consisting of two cylindrical crowns with sharp margins and three pontics. The overall mold filling was satisfactory. The margins of the casting alloys were, however, more rugged and incomplete than those of pure Ti. The most likely reason for this difference is the increased formation of dendrites in the alloy and thus more resistance to fluid flow. Furthermore, the sprue of the alloy was also found to contain some spherical, internal pores. Such pores were rare in the pure Ti castings. The surface reactions were found to be minimal for both of the materials. Increased casting deficiencies observed in the cast bridges of the Ti-6Al-4V alloy, compared with pure Ti, were: 1) the margins of the crowns in the bridge were less complete and 2) there was a tendency to an increased internal porosity, particularly in the sprues.
Ekwall, Anna; Carlberg, Eva; Palmberg, Gunilla; Sloberg, Rut
2018-06-01
Patients of all ages present to the Emergency Department (ED) with fractures that require immobilization using a cast. Various casting materials are used, all with advantages and disadvantages and there are considerable risks associated with fracture management using cast immobilization. The frequency and severity of complications from fiberglass or hybrid casts applied in the emergency setting has not previously been studied. The aim of this audit was to describe all the complications that occurred within 30 days in patients who had a fiberglass cast applied for immobilization of uncomplicated, non-angulated fractures of the foot, ankle or forearm. A retrospective care record audit was conducted that included 430 patients. The most common complications found were skin complications and cast related problems. No severe complications (e.g. compartment syndrome, venous thromboembolism or infection) were found. Fiberglass casts did not cause severe complications in this group of patients with uncomplicated fractures of the extremities. However, 25% of the patients experienced some form of complication. Interventions are needed that minimize the frequency of complications. As with all healthcare interventions, it is crucial that staff applying casts and providing follow-up care are competent. If casts are applied correctly and the patient is well informed and concordant, complications can be avoided. Copyright © 2018 Elsevier Ltd. All rights reserved.
Vojvodic, Svjetlana; Johnson, Brian R; Harpur, Brock A; Kent, Clement F; Zayed, Amro; Anderson, Kirk E; Linksvayer, Timothy A
2015-11-01
The caste fate of developing female honey bee larvae is strictly socially regulated by adult nurse workers. As a result of this social regulation, nurse-expressed genes as well as larval-expressed genes may affect caste expression and evolution. We used a novel transcriptomic approach to identify genes with putative direct and indirect effects on honey bee caste development, and we subsequently studied the relative rates of molecular evolution at these caste-associated genes. We experimentally induced the production of new queens by removing the current colony queen, and we used RNA sequencing to study the gene expression profiles of both developing larvae and their caregiving nurses before and after queen removal. By comparing the gene expression profiles of queen-destined versus worker-destined larvae as well as nurses observed feeding these two types of larvae, we identified larval and nurse genes associated with caste development. Of 950 differentially expressed genes associated with caste, 82% were expressed in larvae with putative direct effects on larval caste, and 18% were expressed in nurses with putative indirect effects on caste. Estimated selection coefficients suggest that both nurse and larval genes putatively associated with caste are rapidly evolving, especially those genes associated with worker development. Altogether, our results suggest that indirect effect genes play important roles in both the expression and evolution of socially influenced traits such as caste.
Modeling the surface contamination of dental titanium investment castings.
Atwood, R C; Lee, P D; Curtis, R V
2005-02-01
The objective of this study was to develop a computational tool for assisting the design of titanium dental castings with minimal defects and to compare computational simulations with casting experiments. Modeling. An in-house cellular-automata solidification and finite-difference diffusion program was coupled with a commercial casting program and applied to (a) simple geometric wedge models and (b) a 3D-laser scan of a molar crown casting. Experimental. Wedges and molar crowns were hand-waxed and investment cast in commercial purity grade 1 (CP-1) titanium by a commercial dental laboratory. The castings were sectioned and analyzed using light and scanning electron microscopy, X-ray microanalysis, and microhardness testing. In the wedge sample, contamination with impurities (Al, Si), including intermetallic precipitates, was found to extend to a depth ranging from 30 to 120 microm depending on the section thickness and hence the local cooling rate. Microstructural and mechanical (hardness) effects were found to a depth ranging from 80 to 250 microm. The coupled micro/macro model predictions showed reasonable agreement for the pattern of contamination. Dental and medical applications demand close dimensional tolerance and freedom from surface impurities and structural flaws in castings having unique shapes. The ability to predict the structural, mechanical, and chemical changes resulting from the casting process will help to design the casting and post-casting processes to minimize these problems.
46 CFR 59.20-1 - Carbon-steel or alloy-steel castings.
Code of Federal Regulations, 2010 CFR
2010-10-01
... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Castings § 59.20-1 Carbon-steel or alloy-steel castings. Defects in carbon-steel or alloy-steel castings may be repaired by welding. The repairs...
46 CFR 59.20-1 - Carbon-steel or alloy-steel castings.
Code of Federal Regulations, 2011 CFR
2011-10-01
... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Castings § 59.20-1 Carbon-steel or alloy-steel castings. Defects in carbon-steel or alloy-steel castings may be repaired by welding. The repairs...
46 CFR 59.20-1 - Carbon-steel or alloy-steel castings.
Code of Federal Regulations, 2013 CFR
2013-10-01
... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Castings § 59.20-1 Carbon-steel or alloy-steel castings. Defects in carbon-steel or alloy-steel castings may be repaired by welding. The repairs...
46 CFR 59.20-1 - Carbon-steel or alloy-steel castings.
Code of Federal Regulations, 2012 CFR
2012-10-01
... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Castings § 59.20-1 Carbon-steel or alloy-steel castings. Defects in carbon-steel or alloy-steel castings may be repaired by welding. The repairs...
46 CFR 59.20-1 - Carbon-steel or alloy-steel castings.
Code of Federal Regulations, 2014 CFR
2014-10-01
... BOILERS, PRESSURE VESSELS AND APPURTENANCES Welding Repairs to Castings § 59.20-1 Carbon-steel or alloy-steel castings. Defects in carbon-steel or alloy-steel castings may be repaired by welding. The repairs...
Y-chromosomal insights into the genetic impact of the caste system in India.
Zerjal, Tatiana; Pandya, Arpita; Thangaraj, Kumarasamy; Ling, Edmund Y S; Kearley, Jennifer; Bertoneri, Stefania; Paracchini, Silvia; Singh, Lalji; Tyler-Smith, Chris
2007-03-01
The caste system has persisted in Indian Hindu society for around 3,500 years. Like the Y chromosome, caste is defined at birth, and males cannot change their caste. In order to investigate the genetic consequences of this system, we have analysed male-lineage variation in a sample of 227 Indian men of known caste, 141 from the Jaunpur district of Uttar Pradesh and 86 from the rest of India. We typed 131 Y-chromosomal binary markers and 16 microsatellites. We find striking evidence for male substructure: in particular, Brahmins and Kshatriyas (but not other castes) from Jaunpur each show low diversity and the predominance of a single distinct cluster of haplotypes. These findings confirm the genetic isolation and drift within the Jaunpur upper castes, which are likely to result from founder effects and social factors. In the other castes, there may be either larger effective population sizes, or less strict isolation, or both.
Metallic Fuel Casting Development and Parameter Optimization Simulations
DOE Office of Scientific and Technical Information (OSTI.GOV)
R.S. Fielding; J. Crapps; C. Unal
One of the advantages of metallic fuel is the abilility to cast the fuel slugs to near net shape with little additional processing. However, the high aspect ratio of the fuel is not ideal for casting. EBR-II fuel was cast using counter gravity injection casting (CGIC) but, concerns have been raised concerning the feasibility of this process for americium bearing alloys. The Fuel Cycle Research and Development program has begun developing gravity casting techniques suitable for fuel production. Compared to CGIC gravity casting does not require a large heel that then is recycled, does not require application of a vacuummore » during melting, and is conducive to re-usable molds. Development has included fabrication of two separate benchscale, approximately 300 grams, systems. To shorten development time computer simulations have been used to ensure mold and crucible designs are feasible and to identify which fluid properties most affect casting behavior and therefore require more characterization.« less
NASA Astrophysics Data System (ADS)
Nastac, Laurentiu; El-Kaddah, Nagy
It is well known that casting at low superheat has a strong influence on the solidification structures of the cast alloy. Recent studies on casting magnesium AZ alloys at low superheat using the Magnetic Suspension Melting (MSM) process have shown that the cast alloy exhibit a fine globular grain structure, and the grain size depend on the cooling rate. This paper describes a stochastic mesoscopic model for predicting the grain structure and segregation in cast alloys at low superheat. This model was applied to predict the globular solidification morphology and solute redistribution of Al in cast Mg AZ31B alloy at different cooling rates. The predictions were found to be in good agreement with the observed grain structure and Al segregation. This makes the model a very useful tool for optimizing the solidification structure of cast magnesium alloys.
Orthograde endodontic retreatment of teeth with individual cast posts: report of two cases.
Ramić, Bojana; Stojanac, Igor; Premović, Milica; Drobac, Milan; Petrović, Ljubomir
2012-01-01
The failure of primary endodontic treatment is manifested by various clinical symptoms following endodontic therapy or, more frequently, by the development of chronic inflammatory process in the apex region without any subjective symptoms. In case of unfavorable outcome of the primary endodontic treatment, orthograde endodontic retreatment is the method of choice for a prolonged therapy. Two female patients, 47 and 44 years old, were presented at the Dental Clinic of Vojvodina for endodontic retreatment of teeth 22, 23 and 13, within the repeated prosthetic restoration. Intraradicular individual cast posts were removed using ultrasonic instruments. Remains of gutta-percha were removed by engine driven rotary re-treatment files, root canals were shaped and cleaned using the crown-down technique, and obturated with gutta-percha and epoxy-resin-based sealer using the lateral compaction technique. When there are metal posts or broken instruments in the root canal, the use of ultrasonic instruments is considered a safe method characterized by negligible tooth substance loss and minimal root damage causing fractures and perforations, and the entire procedure is effective and predictable. Non-surgical orthograde endodontic retreatment, when properly performed in accessible and penetrable root canals, achieves a high cure rate, good and lasting results and eliminates the need for radical procedures, such as apical surgery or tooth extraction. When nonsurgical endodontic retreatment is done, treated teeth must be restored by full coronal coverage as soon as possible, to prevent coronal leakage or fracture.
Koželj, Vesna; Vegnuti, Miljana; Drevenšek, Martina; Hortis-Dzierzbicka, Maria; Gonzalez-Landa, Gonzalo; Hanstein, Siiri; Klimova, Irena; Kobus, Kazimierz; Kobus-Zaleśna, Katarzyna; Semb, Gunvor; Shaw, Bill
2012-11-01
To compare palatal dimensions in 6-year-old children with unilateral cleft lip and palate (UCLP) treated by different protocols with those of noncleft children. Retrospective intercenter outcome study. Patients : Upper dental casts from 129 children with repaired UCLP and 30 controls were analyzed by the trigonometric method. Six European cleft centers. Main outcome measures : Sagittal, transverse, and vertical dimensions of the palate were observed. Palate variables were analyzed with descriptive methods and nonparametric tests. Regarding several various characteristics measured on a relatively small number of subjects, hierarchical, k-means clustering, and principal component analyses were used. Mean values of the observed dimensions for five cleft groups differed significantly from the control (p < .05). The group with one-stage closure of the cleft differed significantly from all other cleft groups in most variables (p < .05). Principal component analysis of all 159 cases identified three clusters with specific morphologic characteristics of the palate. A similar number of treated children were classified into each cluster, while all children without clefts were classified in the same cluster. The percentage of treated children from a particular group that fit this cluster ranged from 0% to 70% and increased with age at palatal closure and number of primary surgical procedures. At 6 years of age, children with stepwise repair and hard palate closure after the age of two more frequently result in palatal dimensions of noncleft control than children with earlier palatal closure and one-stage cleft repair.
[The syndrome of external ligament sprain in the horse].
Collard, X R; Danse, E M; Rombouts, J J
2000-06-01
The treatment of acute complete (grade III) tears of the lateral ligaments of the ankle has generated much controversy in the medical literature. Functional treatment has become the standard treatment as it has been shown that there is no significant difference in long term results whatever the treatment (operative repair and cast, cast alone, or early controlled mobilization). Functional treatment includes only a short period of protection by tape bandage or brace and allows early weight-bearing. Major trauma with avulsion of bone and severe ligamentous damage on both medial and lateral sides of the ankle is however an indication for surgical treatment in the acute phase. Secondary operative reconstruction can be performed in case of persistent instability and laxity of the ankle. Secondary anatomic repair as proposed by Brodström, Duquennoy et al. and Karlsson et al. has a high rate of success and avoids the potential morbidity of harvesting partially or totally the peroneus brevis or other tendon grafts. Evaluation of the injured ankle has improved and in selected patients ultrasonography, arthrography, magnetic resonance imaging or bone scintigraphy may be useful for further evaluation of the injury. The frequency of associated injuries has probably been underestimated. Although ankle sprain is often thought of as an injury involving only the lateral ankle ligaments, there are varied and multiple components to the common sprained ankle. This condition would perhaps more appropriately be designated as the sprained ankle syndrome.
Casting Of Multilayer Ceramic Tapes
NASA Technical Reports Server (NTRS)
Collins, Earl R., Jr.
1991-01-01
Procedure for casting thin, multilayer ceramic membranes, commonly called tapes, involves centrifugal casting at accelerations of 1,800 to 2,000 times normal gravitational acceleration. Layers of tape cast one at a time on top of any previous layer or layers. Each layer cast from slurry of ground ceramic suspended in mixture of solvents, binders, and other components. Used in capacitors, fuel cells, and electrolytic separation of oxygen from air.
Thanseem, Ismail; Thangaraj, Kumarasamy; Chaubey, Gyaneshwer; Singh, Vijay Kumar; Bhaskar, Lakkakula V K S; Reddy, B Mohan; Reddy, Alla G; Singh, Lalji
2006-08-07
India is a country with enormous social and cultural diversity due to its positioning on the crossroads of many historic and pre-historic human migrations. The hierarchical caste system in the Hindu society dominates the social structure of the Indian populations. The origin of the caste system in India is a matter of debate with many linguists and anthropologists suggesting that it began with the arrival of Indo-European speakers from Central Asia about 3500 years ago. Previous genetic studies based on Indian populations failed to achieve a consensus in this regard. We analysed the Y-chromosome and mitochondrial DNA of three tribal populations of southern India, compared the results with available data from the Indian subcontinent and tried to reconstruct the evolutionary history of Indian caste and tribal populations. No significant difference was observed in the mitochondrial DNA between Indian tribal and caste populations, except for the presence of a higher frequency of west Eurasian-specific haplogroups in the higher castes, mostly in the north western part of India. On the other hand, the study of the Indian Y lineages revealed distinct distribution patterns among caste and tribal populations. The paternal lineages of Indian lower castes showed significantly closer affinity to the tribal populations than to the upper castes. The frequencies of deep-rooted Y haplogroups such as M89, M52, and M95 were higher in the lower castes and tribes, compared to the upper castes. The present study suggests that the vast majority (> 98%) of the Indian maternal gene pool, consisting of Indio-European and Dravidian speakers, is genetically more or less uniform. Invasions after the late Pleistocene settlement might have been mostly male-mediated. However, Y-SNP data provides compelling genetic evidence for a tribal origin of the lower caste populations in the subcontinent. Lower caste groups might have originated with the hierarchical divisions that arose within the tribal groups with the spread of Neolithic agriculturalists, much earlier than the arrival of Aryan speakers. The Indo-Europeans established themselves as upper castes among this already developed caste-like class structure within the tribes.
Thanseem, Ismail; Thangaraj, Kumarasamy; Chaubey, Gyaneshwer; Singh, Vijay Kumar; Bhaskar, Lakkakula VKS; Reddy, B Mohan; Reddy, Alla G; Singh, Lalji
2006-01-01
Background India is a country with enormous social and cultural diversity due to its positioning on the crossroads of many historic and pre-historic human migrations. The hierarchical caste system in the Hindu society dominates the social structure of the Indian populations. The origin of the caste system in India is a matter of debate with many linguists and anthropologists suggesting that it began with the arrival of Indo-European speakers from Central Asia about 3500 years ago. Previous genetic studies based on Indian populations failed to achieve a consensus in this regard. We analysed the Y-chromosome and mitochondrial DNA of three tribal populations of southern India, compared the results with available data from the Indian subcontinent and tried to reconstruct the evolutionary history of Indian caste and tribal populations. Results No significant difference was observed in the mitochondrial DNA between Indian tribal and caste populations, except for the presence of a higher frequency of west Eurasian-specific haplogroups in the higher castes, mostly in the north western part of India. On the other hand, the study of the Indian Y lineages revealed distinct distribution patterns among caste and tribal populations. The paternal lineages of Indian lower castes showed significantly closer affinity to the tribal populations than to the upper castes. The frequencies of deep-rooted Y haplogroups such as M89, M52, and M95 were higher in the lower castes and tribes, compared to the upper castes. Conclusion The present study suggests that the vast majority (>98%) of the Indian maternal gene pool, consisting of Indio-European and Dravidian speakers, is genetically more or less uniform. Invasions after the late Pleistocene settlement might have been mostly male-mediated. However, Y-SNP data provides compelling genetic evidence for a tribal origin of the lower caste populations in the subcontinent. Lower caste groups might have originated with the hierarchical divisions that arose within the tribal groups with the spread of Neolithic agriculturalists, much earlier than the arrival of Aryan speakers. The Indo-Europeans established themselves as upper castes among this already developed caste-like class structure within the tribes. PMID:16893451
Silva, Mauricio; Avoian, Tigran; Warnock, Robert Sean; Sadlik, Gal; Ebramzadeh, Edward
2017-09-01
Waterproof casting has been reported to increase patient comfort and satisfaction, and decrease skin irritation. There are no available data on the influence of waterproof casting materials on physical function in pediatric patients. Our aim was to determine whether the use of waterproof casting would result in faster recovery of physical function while maintaining similar clinical outcomes as those obtained with nonwaterproof materials. Twenty-six children with nonangulated or minimally angulated distal radius fractures were assigned randomly to initially receive a short-arm cast made of one of two optional materials: a hybrid mesh material with a waterproof lining or fiberglass with a nonwaterproof skin protector. Two weeks later, the initial cast was removed and replaced with a short-arm cast made of the alternative option. We compared the rate of fracture displacement, physical function, pain, skin changes, itchiness, and patient satisfaction. No evidence of displacement was found in either group. The mean Activities Scale for Kids - Performance (ASK-P) (physical function) score was 10% higher during the period of time when a waterproof cast was used (P=0.04). When a waterproof cast was used during the first 2 weeks of treatment, the mean total ASK-P scores were 23% higher than that when a nonwaterproof one was used during the same period of time (P=0.003). Patients who received a waterproof cast as the initial treatment reported lower functional scores overall and in almost every domain of the ASK-P once they were in a nonwaterproof one; similarly, those who received a nonwaterproof cast as the initial treatment reported higher functional scores overall and in every domain of the ASK-P once they were in a waterproof cast. Compared with a nonwaterproof cast, the use of waterproof casting resulted in comparable levels of pain, itchiness, skin irritability, and overall patient satisfaction. The results of this randomized, cross-over trial suggest that the use of waterproof casting material for the treatment of nondisplaced or minimally displaced distal radius fractures in children can result in a faster recovery of physical function, while providing comparable stability, pain, itchiness, skin irritability, and overall patient satisfaction. II.
Trivedi, Madhukar H; Wisniewski, Stephen R; Morris, David W; Fava, Maurizio; Kurian, Benji T; Gollan, Jackie K; Nierenberg, Andrew A; Warden, Diane; Gaynes, Bradley N; Luther, James F; Rush, A John
2011-06-01
US Food and Drug Administration (FDA) warnings recommend monitoring negative symptoms associated with the initiation of antidepressant medications as these symptoms may interfere with full recovery and pose safety concerns. There is currently no brief, reliable rating instrument for assessing treatment-emergent, negative symptoms. We evaluated the psychometric properties of 2 versions of the newly developed 17-item Concise Associated Symptom Tracking (CAST) scale, the CAST Clinician Rating (CAST-C) and CAST Self-Rated (CAST-SR), which are brief instruments designed to measure the 5 relevant associated symptom domains (irritability, anxiety, mania, insomnia, and panic). The study enrolled 265 outpatients with major depressive disorder (MDD), from July 2007 through February 2008, into an 8-week, open-label trial with a selective serotonin reuptake inhibitor. Diagnosis of MDD was determined by the Psychiatric Diagnostic Screening questionnaire and an MDD checklist based on DSM-IV-TR criteria. Suicidality (suicidal ideation with associated behaviors) is 1 of 9 symptoms of MDD (depressed mood, loss of interest, appetite or weight change, sleep disturbance, reduced concentration or indecisiveness, fatigue or decreased energy, psychomotor agitation or retardation, feelings of worthlessness or excessive guilt). Psychometric evaluations were conducted on both versions of the CAST. Cronbach α was .80 (CAST-C) and .81 (CAST-SR). Factor analysis identified 5 factors for each scale: (1) irritability, (2) anxiety, (3) mania, (4) insomnia, and (5) panic. When the item that cross-loaded on 2 factors was eliminated, the 16-item solution had a better goodness of fit (CAST-C: 0.90 vs 0.87; CAST-SR: 0.88 vs 0.84). Cronbach α for the 16-item versions was .77 (CAST-C) and .78 (CAST-SR). The 5 associated CAST symptom domains correlated well with other standard measures of these domains. The 16-item CAST-C and CAST-SR demonstrated excellent psychometric properties. These are potentially useful measures for monitoring treatment-emergent negative symptoms associated with antidepressants, as recommended by the FDA. Clinicaltrials.gov Identifier: NCT00532103. © Copyright 2011 Physicians Postgraduate Press, Inc.
Women's health in a rural community in Kerala, India: do caste and socioeconomic position matter?
Mohindra, K S; Haddad, Slim; Narayana, D
2006-01-01
Objectives To examine the social patterning of women's self‐reported health status in India and the validity of the two hypotheses: (1) low caste and lower socioeconomic position is associated with worse reported health status, and (2) associations between socioeconomic position and reported health status vary across castes. Design Cross‐sectional household survey, age‐adjusted percentages and odds ratios, and multilevel multinomial logistic regression models were used for analysis. Setting A panchayat (territorial decentralised unit) in Kerala, India, in 2003. Participants 4196 non‐elderly women. Outcome measures Self‐perceived health status and reported limitations in activities in daily living. Results Women from lower castes (scheduled castes/scheduled tribes (SC/ST) and other backward castes (OBC) reported a higher prevalence of poor health than women from forward castes. Socioeconomic inequalities were observed in health regardless of the indicators, education, women's employment status or household landholdings. The multilevel multinomial models indicate that the associations between socioeconomic indicators and health vary across caste. Among SC/ST and OBC women, the influence of socioeconomic variables led to a “magnifying” effect, whereas among forward caste women, a “buffering” effect was found. Among lower caste women, the associations between socioeconomic factors and self‐assessed health are graded; the associations are strongest when comparing the lowest and highest ratings of health. Conclusions Even in a relatively egalitarian state in India, there are caste and socioeconomic inequalities in women's health. Implementing interventions that concomitantly deal with caste and socioeconomic disparities will likely produce more equitable results than targeting either type of inequality in isolation. PMID:17108296
Improving Metal Casting Process
NASA Technical Reports Server (NTRS)
1998-01-01
Don Sirois, an Auburn University research associate, and Bruce Strom, a mechanical engineering Co-Op Student, are evaluating the dimensional characteristics of an aluminum automobile engine casting. More accurate metal casting processes may reduce the weight of some cast metal products used in automobiles, such as engines. Research in low gravity has taken an important first step toward making metal products used in homes, automobiles, and aircraft less expensive, safer, and more durable. Auburn University and industry are partnering with NASA to develop one of the first accurate computer model predictions of molten metals and molding materials used in a manufacturing process called casting. Ford Motor Company's casting plant in Cleveland, Ohio is using NASA-sponsored computer modeling information to improve the casting process of automobile and light-truck engine blocks.
Numerical simulation of the casting process of titanium tooth crowns and bridges.
Wu, M; Augthun, M; Wagner, I; Sahm, P R; Spiekermann, H
2001-06-01
The objectives of this paper were to simulate the casting process of titanium tooth crowns and bridges; to predict and control porosity defect. A casting simulation software, MAGMASOFT, was used. The geometry of the crowns with fine details of the occlusal surface were digitized by means of laser measuring technique, then converted and read in the simulation software. Both mold filling and solidification were simulated, the shrinkage porosity was predicted by a "feeding criterion", and the gas pore sensitivity was studied based on the mold filling and solidification simulations. Two types of dental prostheses (a single-crown casting and a three-unit-bridge) with various sprue designs were numerically "poured", and only one optimal design for each prosthesis was recommended for real casting trial. With the numerically optimized design, real titanium dental prostheses (five replicas for each) were made on a centrifugal casting machine. All the castings endured radiographic examination, and no porosity was detected in the cast prostheses. It indicates that the numerical simulation is an efficient tool for dental casting design and porosity control. Copyright 2001 Kluwer Academic Publishers
NASA Astrophysics Data System (ADS)
Qin, Fangcheng; Li, Yongtang; Ju, Li
2017-03-01
Hot compression tests of sand casting and centrifugal casting Q235B flange blanks were performed at strain rate range of 0.01-5 s-1 and temperature range of 850-1,150 °C. The evolutions of microstructure and texture were revealed. The constitutive models based on Arrhenius constitutive modeling were proposed by considering the effects of strain on material constants. The results show that recrystallization in centrifugal casting Q235B is more apparent than that in sand casting, resulting in the finer grains and lower flow stress for centrifugal casting Q235B. The intensities of textures slightly weaken with the increase of temperature. At 1,050 °C and 5 s-1, the textures of sand casting are characterized by strong {001}<100> and {001}<110>, which are related with severe deformation, while the textures of centrifugal casting are composed of {110}<110> and {111}<112>, which are related with dynamic recovery and shear deformation. A good agreement between the predicted and experimental flow stress is achieved and demonstrates that the proposed constitutive models are reliable.
Development of a new casting method to fabricate U–Zr alloy containing minor actinides
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jong Hwan Kim; Hoon Song; Hyung Tae Kim
2014-01-01
Metal fuel slugs of U–Zr alloys for a sodium-cooled fast reactor (SFR) have conventionally been fabricated using an injection casting method. However, casting alloys containing volatile radioactive constituents, such as Am, are problematic in a conventional injection casting method. As an alternative fabrication method, low pressure gravity casting has been developed. Casting soundness, microstructural characteristics, alloying composition, density, and fuel losses were evaluated for the following as-cast fuel slugs: U–10 wt% Zr, U–10 wt% Zr–5 wt% RE, and U–10 wt% Zr–5 wt% RE–5 wt% Mn. The U and Zr contents were uniform throughout the matrix, and impurities such as oxyen,more » carbon, and nitrogen satisfied the specification of total impurities less than 2,000 ppm. The appearance of the fuel slugs was generally sound, and the internal integrity was shown to be satisfactory based on gamma-ray radiography. In a volatile surrogate casting test, the U–Zr–RE–Mn fuel slug showed that nearly all of the manganese was retained when casting was done under an inert atmosphere.« less
The perception of 3-D shape from shadows cast onto curved surfaces.
Norman, J Farley; Lee, Young-lim; Phillips, Flip; Norman, Hideko F; Jennings, L RaShae; McBride, T Ryan
2009-05-01
In a natural environment, cast shadows abound. Objects cast shadows both upon themselves and upon background surfaces. Previous research on the perception of 3-D shape from cast shadows has only examined the informativeness of shadows cast upon flat background surfaces. In outdoor environments, however, background surfaces often possess significant curvature (large rocks, trees, hills, etc.), and this background curvature distorts the shape of cast shadows. The purpose of this study was to determine the extent to which observers can "discount" the distorting effects of curved background surfaces. In our experiments, observers viewed deforming or static shadows of naturally shaped objects, which were cast upon flat and curved background surfaces. The results showed that the discrimination of 3-D object shape from cast shadows was generally invariant over the distortions produced by hemispherical background surfaces. The observers often had difficulty, however, in identifying the shadows cast onto saddle-shaped background surfaces. The variations in curvature which occur in different directions on saddle-shaped background surfaces cause shadow distortions that lead to difficulties in object recognition and discrimination.
NASA Astrophysics Data System (ADS)
Li, You Yun; Tsai, DeChang; Hwang, Weng Sing
2008-06-01
The purpose of this study is to develop a technique of numerically simulating the microstructure of 17-4PH (precipitation hardening) stainless steel during investment casting. A cellular automation (CA) algorithm was adopted to simulate the nucleation and grain growth. First a calibration casting was made, and then by comparing the microstructures of the calibration casting with those simulated using different kinetic growth coefficients (a2, a3) in CA, the most appropriate set of values for a2 and a3 would be obtained. Then, this set of values was applied to the microstructure simulation of a separate casting, where the casting was actually made. Through this approach, this study has arrived at a set of growth kinetic coefficients from the calibration casting: a2 is 2.9 × 10-5, a3 is 1.49 × 10-7, which is then used to predict the microstructure of the other test casting. Consequently, a good correlation has been found between the microstructure of actual 17-4PH casting and the simulation result.
Consanguineous marriages and matrimonial distance: a study among three South Indian caste groups.
Reddy, P G
1988-12-01
Reddy studies consanguineous marriages and matrimonial distance in 3 castes of Nellore district, Andhra Pradesh, South India. The castes include the well-to-do agricultural caste, the Desuri Kapu; the 2nd, artisan caste in the middle of the hierarchy, the Devanga; and the third caste at the bottom of the social ladder, the Mala. During field work conducted in 1978-1979, prominent elders of the villages were approached; information on the consanguinity of marriage and matrimonial distance was gathered through intensive interviews of both men and women from all the households of the 3 castes. Among the total of 979 marriages, 28.9% occurred within the village, the proportion of intra-village marriages being significantly higher in Nellore taluk than in Sullurpet. The 3 castes overall show little difference in the incidence of intra-village marriages, but there is some within caste regional variation in the incidence of intra-village marriages, the Devanga showing a significantly higher incidence in Nellore than in Sullurpet. Intra-village marriages are more common among consanguineous couples (41.5%) than among non-consanguineous (18.3%), a highly significant excess in each of the caste groups. In short, Reddy concludes that intra-village marriages are more common among consanguineous couples than non-consanguineous, and mean matrimonial distance is also lower.
Caste development and evolution in ants: it's all about size.
Trible, Waring; Kronauer, Daniel J C
2017-01-01
Female ants display a wide variety of morphological castes, including workers, soldiers, ergatoid (worker-like) queens and queens. Alternative caste development within a species arises from a variable array of genetic and environmental factors. Castes themselves are also variable across species and have been repeatedly gained and lost throughout the evolutionary history of ants. Here, we propose a simple theory of caste development and evolution. We propose that female morphology varies as a function of size, such that larger individuals possess more queen-like traits. Thus, the diverse mechanisms that influence caste development are simply mechanisms that affect size in ants. Each caste-associated trait has a unique relationship with size, producing a phenotypic space that permits some combinations of worker- and queen-like traits, but not others. We propose that castes are gained and lost by modifying the regions of this phenotypic space that are realized within a species. These modifications can result from changing the size-frequency distribution of individuals within a species, or by changing the association of tissue growth and size. We hope this synthesis will help unify the literature on caste in ants, and facilitate the discovery of molecular mechanisms underlying caste development and evolution. © 2017. Published by The Company of Biologists Ltd.
A new method to acquire 3-D images of a dental cast
NASA Astrophysics Data System (ADS)
Li, Zhongke; Yi, Yaxing; Zhu, Zhen; Li, Hua; Qin, Yongyuan
2006-01-01
This paper introduced our newly developed method to acquire three-dimensional images of a dental cast. A rotatable table, a laser-knife, a mirror, a CCD camera and a personal computer made up of a three-dimensional data acquiring system. A dental cast is placed on the table; the mirror is installed beside the table; a linear laser is projected to the dental cast; the CCD camera is put up above the dental cast, it can take picture of the dental cast and the shadow in the mirror; while the table rotating, the camera records the shape of the laser streak projected on the dental cast, and transmit the data to the computer. After the table rotated one circuit, the computer processes the data, calculates the three-dimensional coordinates of the dental cast's surface. In data processing procedure, artificial neural networks are enrolled to calibrate the lens distortion, map coordinates form screen coordinate system to world coordinate system. According to the three-dimensional coordinates, the computer reconstructs the stereo image of the dental cast. It is essential for computer-aided diagnosis and treatment planning in orthodontics. In comparison with other systems in service, for example, laser beam three-dimensional scanning system, the characteristic of this three-dimensional data acquiring system: a. celerity, it casts only 1 minute to scan a dental cast; b. compact, the machinery is simple and compact; c. no blind zone, a mirror is introduced ably to reduce blind zone.
Obtaining of High Cr Content Cast Iron Materials
NASA Astrophysics Data System (ADS)
Florea, C.; Bejinariu, C.; Carcea, I.; Cimpoesu, N.; Chicet, D. L.; Savin, C.
2017-06-01
We have obtained, through the classic casting process, 3 highly chromium-based experimental alloys proposed for replacing the FC 250 classical cast iron in braking applications. Casting was carried out in an induction furnace and cast into moulds made of KALHARTZ 8500 resin casting mixture and HARTER hardener at SC RanCon SRL Iasi. It is known that the microstructure of the cast iron is a combination of martensite with a small amount of residual austenite after the heat treatment of the ingot. In the case of high-alloy chromium alloys, the performance of the material is due to the presence of M7C3 carbides distributed in the iron matrix Resistance to machining and deformation is based on alloy composition and microstructure, while abrasion resistance will depend on properties and wear conditions.
Possibility of reconstruction of dental plaster cast from 3D digital study models
2013-01-01
Objectives To compare traditional plaster casts, digital models and 3D printed copies of dental plaster casts based on various criteria. To determine whether 3D printed copies obtained using open source system RepRap can replace traditional plaster casts in dental practice. To compare and contrast the qualities of two possible 3D printing options – open source system RepRap and commercially available 3D printing. Design and settings A method comparison study on 10 dental plaster casts from the Orthodontic department, Department of Stomatology, 2nd medical Faulty, Charles University Prague, Czech Republic. Material and methods Each of 10 plaster casts were scanned by inEos Blue scanner and the printed on 3D printer RepRap [10 models] and ProJet HD3000 3D printer [1 model]. Linear measurements between selected points on the dental arches of upper and lower jaws on plaster casts and its 3D copy were recorded and statistically analyzed. Results 3D printed copies have many advantages over traditional plaster casts. The precision and accuracy of the RepRap 3D printed copies of plaster casts were confirmed based on the statistical analysis. Although the commercially available 3D printing enables to print more details than the RepRap system, it is expensive and for the purpose of clinical use can be replaced by the cheaper prints obtained from RepRap printed copies. Conclusions Scanning of the traditional plaster casts to obtain a digital model offers a pragmatic approach. The scans can subsequently be used as a template to print the plaster casts as required. Using 3D printers can replace traditional plaster casts primarily due to their accuracy and price. PMID:23721330
Wooding, Stephen; Ostler, Christopher; Prasad, B V Ravi; Watkins, W Scott; Sung, Sandy; Bamshad, Mike; Jorde, Lynn B
2004-08-01
Genetic, ethnographic, and historical evidence suggests that the Hindu castes have been highly endogamous for several thousand years and that, when movement between castes does occur, it typically consists of females joining castes of higher social status. However, little is known about migration rates in these populations or the extent to which migration occurs between caste groups of low, middle, and high social status. To investigate these aspects of migration, we analyzed the largest collection of genetic markers collected to date in Hindu caste populations. These data included 45 newly typed autosomal short tandem repeat polymorphisms (STRPs), 411 bp of mitochondrial DNA sequence, and 43 Y-chromosomal single-nucleotide polymorphisms that were assayed in more than 200 individuals of known caste status sampled in Andrah Pradesh, in South India. Application of recently developed likelihood-based analyses to this dataset enabled us to obtain genetically derived estimates of intercaste migration rates. STRPs indicated migration rates of 1-2% per generation between high-, middle-, and low-status caste groups. We also found support for the hypothesis that rates of gene flow differ between maternally and paternally inherited genes. Migration rates were substantially higher in maternally than in paternally inherited markers. In addition, while prevailing patterns of migration involved movement between castes of similar rank, paternally inherited markers in the low-status castes were most likely to move into high-status castes. Our findings support earlier evidence that the caste system has been a significant, long-term source of population structuring in South Indian Hindu populations, and that patterns of migration differ between males and females. Copyright 2004 Springer-Verlag
Tarver, Matthew R; Coy, Monique R; Scharf, Michael E
2012-07-01
Termites are eusocial insects that jointly utilize juvenile hormone (JH), pheromones, and other semiochemicals to regulate caste differentiation and achieve caste homeostasis. Prior EST sequencing from the symbiont-free gut transcriptome of Reticulitermes flavipes unexpectedly revealed a number of unique cytochrome P450 (Cyp) transcripts, including fragments of a Cyp15 family gene (Cyp15F1) with homology to other insect Cyp15s that participate in JH biosynthesis. The present study investigated the role of Cyp15F1 in termite caste polyphenism and specifically tested the hypothesis that it plays a role in JH-dependent caste differentiation. After assembling the full-length Cyp15F1 cDNA sequence, we (i) determined its mRNA tissue expression profile, (ii) investigated mRNA expression changes in response to JH and the caste-regulatory primer pheromones γ-cadinene (CAD) and γ-cadinenal (ALD), and (iii) used RNA interference (RNAi) in combination with caste differentiation bioassays to investigate gene function at the phenotype level. Cyp15F1 has ubiquitous whole-body expression (including gut tissue); is rapidly and sustainably induced from 3 h to 48 h by JH, CAD, and ALD; and functions at least in part by facilitating JH-dependent soldier caste differentiation. These findings provide the second example of a termite caste regulatory gene identified through the use of RNAi, and significantly build upon our understanding of termite caste homeostatic mechanisms. These results also reinforce the concept of environmental caste determination in termites by revealing how primer pheromones, as socioenvironmental factors, can directly influence Cyp15 expression and caste differentiation. © 2012 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fasoyinu, Yemi
2014-03-31
Current vehicles use mostly ferrous components for structural applications. It is possible to reduce the weight of the vehicle by substituting these parts with those made from light metals such as aluminum and magnesium. Many alloys and manufacturing processes can be used to produce these light metal components and casting is known to be most economical. One of the high integrity casting processes is permanent mold casting which is the focus of this research report. Many aluminum alloy castings used in automotive applications are produced by the sand casting process. Also, aluminum-silicon (Al-Si) alloys are the most widely used alloymore » systems for automotive applications. It is possible that by using high strength aluminum alloys based on an aluminum-copper (Al-Cu) system and permanent mold casting, the performance of these components can be enhanced significantly. This will also help to further reduce the weight. However, many technological obstacles need to be overcome before using these alloys in automotive applications in an economical way. There is very limited information in the open literature on gravity and low-pressure permanent mold casting of high strength aluminum alloys. This report summarizes the results and issues encountered during the casting trials of high strength aluminum alloy 206.0 (Al-Cu alloy) and moderate strength alloy 535.0 (Al-Mg alloy). Five engineering components were cast by gravity tilt-pour or low pressure permanent mold casting processes at CanmetMATERIALS (CMAT) and two production foundries. The results of the casting trials show that high integrity engineering components can be produced successfully from both alloys if specific processing parameters are used. It was shown that a combination of melt processing and mold temperature is necessary for the elimination of hot tears in both alloys.« less
Multidisciplinary approach to improve the quality of below-knee plaster casting.
Williams, John Teudar; Kedrzycki, Marta; Shenava, Yathish
2018-01-01
In our trauma unit, we noted a high rate of incorrectly applied below-knee casts for ankle fractures, in some cases requiring reapplication. This caused significant discomfort and inconvenience for patients and additional burden on plaster-room services. Our aim was to improve the quality of plaster casts and reduce the proportion that needed to be reapplied. Our criteria for plaster cast quality were based on the British Orthopaedic Association Casting Standards (2015) and included neutral (plantargrade) ankle position, adequacy of fracture reduction and rate of cast reapplication. Baseline data collection was performed over a 2-month period by two independent reviewers. After distributing findings and presenting to relevant departments, practical casting sessions with orthopaedic technicians were arranged for the multidisciplinary team responsible for casting. This was later supplemented by new casting guidelines in clinical areas and available online. Postintervention data collection was performed over two separate cycles to assess the effect and permanence of intervention. Data from the preintervention period (n=29) showed median ankle position was 32° plantarflexion (PF), with nine (31%) inadequate reductions and six (20%) backslabs reapplied. Following Plan-Do-Study-Act (PDSA) 1, ankle position was significantly improved (median 25° PF), there were fewer inadequate reductions (12%; 2/17) and a lower rate of reapplication (0%; 0/17). After PDSA 2 (n=16), median ankle position was 21° PF, there was one (6%) inadequate reduction and two (12%) reapplications of casts. Following implementation of plaster training sessions for accident and emergency and junior orthopaedic staff, in addition to publishing guidance and new protocol, there has been a sustained improvement in the quality of below-knee backslabs and fewer cast reapplications. These findings justify continuation and expansion of the current programme to include other commonly applied plaster casts.
Prasad, Rahul; Al-Keraif, Abdulaziz Abdullah; Kathuria, Nidhi; Gandhi, P V; Bhide, S V
2014-02-01
The purpose of this study was to determine whether the ringless casting and accelerated wax-elimination techniques can be combined to offer a cost-effective, clinically acceptable, and time-saving alternative for fabricating single unit castings in fixed prosthodontics. Sixty standardized wax copings were fabricated on a type IV stone replica of a stainless steel die. The wax patterns were divided into four groups. The first group was cast using the ringless investment technique and conventional wax-elimination method; the second group was cast using the ringless investment technique and accelerated wax-elimination method; the third group was cast using the conventional metal ring investment technique and conventional wax-elimination method; the fourth group was cast using the metal ring investment technique and accelerated wax-elimination method. The vertical marginal gap was measured at four sites per specimen, using a digital optical microscope at 100× magnification. The results were analyzed using two-way ANOVA to determine statistical significance. The vertical marginal gaps of castings fabricated using the ringless technique (76.98 ± 7.59 μm) were significantly less (p < 0.05) than those castings fabricated using the conventional metal ring technique (138.44 ± 28.59 μm); however, the vertical marginal gaps of the conventional (102.63 ± 36.12 μm) and accelerated wax-elimination (112.79 ± 38.34 μm) castings were not statistically significant (p > 0.05). The ringless investment technique can produce castings with higher accuracy and can be favorably combined with the accelerated wax-elimination method as a vital alternative to the time-consuming conventional technique of casting restorations in fixed prosthodontics. © 2013 by the American College of Prosthodontists.
Improved Net-Level Filling And Finishing Of Large Castings
NASA Technical Reports Server (NTRS)
Johnson, Erik P.; Brown, Richard F.
1995-01-01
Improved method of vacuum casting of large, generally cylindrical objects to net sizes and shapes reduces amount of direct manual labor by workers in proximity to cast material. Original application for which method devised is fabrication of solid rocket-motor segments containing solid propellant, wherein need to minimize exposure of workers to propellant material being cast. Improved method adaptable to other applications involving large castings of toxic, flammable, or otherwise hazardous materials.
Efficiency and Safety: The Best Time to Valve a Plaster Cast.
Steiner, Samuel R H; Gendi, Kirollos; Halanski, Matthew A; Noonan, Kenneth J
2018-04-18
The act of applying, univalving, and spreading a plaster cast to accommodate swelling is commonly performed; however, cast saws can cause thermal and/or abrasive injury to the patient. This study aims to identify the optimal time to valve a plaster cast so as to reduce the risk of cast-saw injury and increase spreading efficiency. Plaster casts were applied to life-sized pediatric models and were univalved at set-times of 5, 8, 12, or 25 minutes. Outcome measures included average and maximum force applied during univalving, blade-to-skin touches, cut time, force needed to spread, number of spread attempts, spread completeness, spread distance, saw blade temperature, and skin surface temperature. Casts allowed to set for ≥12 minutes had significantly fewer blade-to-skin touches compared with casts that set for <12 minutes (p < 0.001). For average and maximum saw blade force, no significant difference was observed between individual set-times. However, in a comparison of the shorter group (<12 minutes) and the longer group (≥12 minutes), the longer group had a higher average force (p = 0.009) but a lower maximum force (p = 0.036). The average temperature of the saw blade did not vary between groups. The maximum force needed to "pop," or spread, the cast was greater for the 5-minute and 8-minute set-times. Despite requiring more force to spread the cast, 0% of attempts at 5 minutes and 54% of attempts at 8 minutes were successful in completely spreading the cast, whereas 100% of attempts at 12 and 25 minutes were successful. The spread distance was greatest for the 12-minute set-time at 5.7 mm. Allowing casts to set for 12 minutes is associated with decreased blade-to-skin contact, less maximum force used with the saw blade, and a more effective spread. Adherence to the 12-minute interval could allow for fewer cast-saw injuries and more effective spreading.
Effect of dental technician disparities on the 3-dimensional accuracy of definitive casts.
Emir, Faruk; Piskin, Bulent; Sipahi, Cumhur
2017-03-01
Studies that evaluated the effect of dental technician disparities on the accuracy of presectioned and postsectioned definitive casts are lacking. The purpose of this in vitro study was to evaluate the accuracy of presectioned and postsectioned definitive casts fabricated by different dental technicians by using a 3-dimensional computer-aided measurement method. An arch-shaped metal master model consisting of 5 abutments resembling prepared mandibular incisors, canines, and first molars and with a 6-degree total angle of convergence was designed and fabricated by computer-aided design and computer-aided manufacturing (CAD-CAM) technology. Complete arch impressions were made (N=110) from the master model, using polyvinyl siloxane (PVS) and delivered to 11 dental technicians. Each technician fabricated 10 definitive casts with dental stone, and the obtained casts were numbered. All casts were sectioned, and removable dies were obtained. The master model and the presectioned and postsectioned definitive casts were digitized with an extraoral scanner, and the virtual master model and virtual presectioned and postsectioned definitive casts were obtained. All definitive casts were compared with the master model by using computer-aided measurements, and the 3-dimensional accuracy of the definitive casts was determined with best fit alignment and represented in color-coded maps. Differences were analyzed using univariate analyses of variance, and the Tukey honest significant differences post hoc tests were used for multiple comparisons (α=.05). The accuracy of presectioned and postsectioned definitive casts was significantly affected by dental technician disparities (P<.001). The largest dimensional changes were detected in the anterior abutments of both of the definitive casts. The changes mostly occurred in the mesiodistal dimension (P<.001). Within the limitations of this in vitro study, the accuracy of presectioned and postsectioned definitive casts is susceptible to dental technician differences. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
7 CFR 1160.607 - Tabulation of ballots.
Code of Federal Regulations, 2010 CFR
2010-01-01
... referendum agent shall verify the validity of all ballots cast in accordance with the instructions and... ballots cast, including the disqualified ballots, shall be ascertained. The number of ballots cast approving, the number of ballots cast disapproving, and the pounds of fluid milk products distributed during...
75 FR 23295 - Iron Construction Castings From Brazil, Canada, and China
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-03
... ``heavy'' iron construction castings from Brazil, the antidumping duty order on ``heavy'' iron... the countervailing duty order on ``heavy'' iron construction castings from Brazil, the antidumping duty order on ``heavy'' iron construction castings from Canada, and the antidumping duty orders on iron...
Alfadda, Sara A
2014-01-01
To use a novel approach to measure the amount of vertical marginal gap in computer numeric controlled (CNC)-milled titanium frameworks and conventional cast frameworks. Ten cast frameworks were fabricated on the mandibular master casts of 10 patients. Then, 10 CNC-milled titanium frameworks were fabricated by laser scanning the cast frameworks. The vertical marginal gap was measured and analyzed using the Contura-G2 coordinate measuring machine and special computer software. The CNC-milled titanium frameworks showed an overall reduced mean vertical gap compared with the cast frameworks in all five analogs. This difference was highly statistically significant in the distal analogs. The largest mean gap in the cast framework was recorded in the most distal analogs, and the least amount was in the middle analog. Neither of the two types of frameworks provided a completely gap-free superstructure. The CNCmilled titanium frameworks showed a significantly smaller vertical marginal gap than the cast frameworks.
Emulsion based cast booster - a priming system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gupta, R.N.; Mishra, A.K.
2005-07-01
This paper explores the potential of emulsion based cast booster to be used as primer to initiate bulk delivered emulsion explosives used in mines. An attempt has been made for comparative study between conventional cast booster and emulsion based cast booster in terms of the initiation process developed and their capability to develop and maintain the stable detonation process in the column explosives. The study has been conducted using a continuous velocity of detonation (VOD) measuring instrument. During this study three blasts have been monitored. In each blast two holes have been selected for study, the first hole being initiatedmore » with conventional cast booster while the other one with emulsion based cast booster. The findings of the study advocates that emulsion based cast booster is capable of efficient priming of bulk delivered column explosive with stable detonation process in the column. Further, the booster had advantages over the conventional PETN/TNT based cast booster. 5 refs., 2 figs., 1 tab., 1 photo.« less
Y-chromosomal insights into the genetic impact of the caste system in India
Zerjal, Tatiana; Pandya, Arpita; Thangaraj, Kumarasamy; Ling, Edmund Y. S.; Kearley, Jennifer; Bertoneri, Stefania; Paracchini, Silvia; Singh, Lalji; Tyler-Smith, Chris
2008-01-01
The caste system has persisted in Indian Hindu society for around 3,500 years. Like the Y chromosome, caste is defined at birth, and males cannot change their caste. In order to investigate the genetic consequences of this system, we have analysed male-lineage variation in a sample of 227 Indian men of known caste, 141 from the Jaunpur district of Uttar Pradesh and 86 from the rest of India. We typed 131 Y-chromosomal binary markers and 16 microsatellites. We find striking evidence for male substructure: in particular, Brahmins and Kshatriyas (but not other castes) from Jaunpur each show low diversity and the predominance of a single distinct cluster of haplotypes. These findings confirm the genetic isolation and drift within the Jaunpur upper castes, which are likely to result from founder effects and social factors. In the other castes, there may be either larger effective population sizes, or less strict isolation, or both. PMID:17075717
Caste-, work-, and descent-based discrimination as a determinant of health in social epidemiology.
Patil, Rajan R
2014-01-01
Social epidemiology explores health in the context of broad social determinants of health, where the boundary lines between health and politics appear increasingly blurred. Social determinants of health such as caste, discrimination, and social exclusion are inherently political in nature, hence it becomes imperative to look at health through a broader perspective of political philosophy, ideology, and caste that imposes enormous obstacles to a person's full attainment of civil, political, economic, social, and cultural rights. Caste is descent based and hereditary in nature. It is a characteristic determined by one's birth into a particular caste, irrespective of the faith practiced by the individual. Caste denotes a system of rigid social stratification into ranked groups defined by descent and occupation. Under various caste systems throughout the world, caste divisions also dominate in housing, marriage, and general social interaction divisions that are reinforced through the practice and threat of social ostracism, economic boycotts, and even physical violence-all of which undermine health equality.
Direct Cast U-6Nb – 2017 Progress on Cylindrical Castings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aikin, Jr., Robert M.
2017-10-04
This report describes work to further develop a sound technical basis and best practices for mold design and process parameters for the Direct Casting of U-6wt%Nb components. One major challenge to the production of U-6Nb components is the propensity for niobium segregation during casting and solidification. This is especially true for cylindrical castings where the vertical side walls allow flotation of Nb resulting in severe inverse macrosegregation. In this work, a small (120 mm diameter by 180 mm tall) and large cylinder (250 mm diameter by 310 mm tall) are examined with a focus on reducing, or eliminating, niobium segregation.more » It is demonstrated that counter gravity casting (top-to-bottom solidification) can be used to minimize segregation in the small cylinder. Attempts to counter gravity cast the large cylinder were unsuccessful, in large part due to size limitations of the current furnace. A path forward for casting of the large cylinders is discussed.« less
Halanski, Matthew A; Harper, Benjamin L; Cassidy, Jeffry A; Crawford, Haemish A
2013-07-01
This is a technique article discussing 3 alternative frames for casting children with infantile scoliosis. To provide surgeons with alternatives to expensive specialized casting tables to allow local treatment of these children utilizing readily available materials present at most institutions. Casting for infantile scoliosis has become more popular as reports have shown promising results with this technique without the morbidity and complications associated with more invasive procedures. However, without a specialized casting table, treating these patients has been limited to a few centers throughout the country often causing patients to travel large distances to receive care. Three different alternatives to commercially available casting frames are presented. Requirements, setup, and techniques are discussed. Each surgeon has had success with each of these frames. These provide adequate support and traction while allowing enough access to the trunk to apply a well-molded cast. Cotrel/Metha casting for infantile scoliosis can be accomplished without a specialized table using commonly available equipment.
Development of the Electromagnetic Continuous Casting Technology for of Magnesium Alloys
NASA Astrophysics Data System (ADS)
Park, Joon-Pyo; Kim, Myoung-Gyun; Kim, Jong-Ho; Lee, Gyu-Chang
Currently, magnesium billets produced by ingot casting or direct chill casting process, result in low-quality surfaces and low productivity, Continuous casting technology to solve these problem has not only high-quality surface billets with fine-grained and homogeneous microstructure but also cost down. The latent heat of fusion per weight (J/g) of magnesium is similar to other metals, however, considering the heat emitted to the mold surface during continuous casting in meniscus region and converting it to the latent heat of fusion per volume, magnesium will be rapidly solidified in the mold during continuous casting, which induces subsequent surface defect formation. In this study, electromagnetic casting and stirring (EMC and EMS) techniques are proposed to control solidification process conveniently by compensating the low latent heat of solidification by volume and to fabricate magnesium billet with high-quality surface. This technique was extended to large scale billets up to 300 mm diameter and continuous casting was successfully conducted. Then magnesium billet was used for the fabrication of prototype automobile pulley.
Vart, Priya; Jaglan, Ajay; Shafique, Kashif
2015-06-05
Caste is one of the traditional measures of social segregation in India and differs from other indicators as it is both, endogamous and hereditary. Evidence suggests that belonging to lower castes exposes one to social inequalities and affects health adversely. We examined the association of caste with childhood anemia in India and explored the effect modifying role of adult education and household wealth. A cross-sectional analysis of National Family Health Survey (NFHS) data of 43,484 children aged 6-59 months was performed. Poisson regression analysis was conducted to study the association between caste and childhood anemia accounting for various maternal, child, and household related variables. Caste was categorized as "other caste" (least disadvantageous), "other backward caste", "scheduled tribe" and "scheduled caste" (most disadvantageous). Anemia was defined as mild (hemoglobin level 7-11 g/dL), moderate (hemoglobin level 5-7 g/dL) and severe (hemoglobin level <5 g/dL). We found that children in scheduled caste had higher risk of having anemia [mild anemia: RR = 1.10, 95% CI = 1.05-1.15; moderate anemia: RR = 1.19, 95% CI = 1.14-1.24; severe anemia: RR = 1.87, 95% CI = 1.51-2.31] after accounting for child, maternal and household covariates including adult education and household wealth. The interaction of caste with adult education and household wealth was not statistically significant for any level of anemia. Sensitivity analyses for children born to mothers of age ≥ 18 years at first child birth and body mass index (BMI) ≥ 18.5 kg/m(2), resulted in similar findings. Caste is an independent determinant of childhood anemia in India. The level of adult education and household wealth did not modify the association between caste and childhood anemia. The findings may be used for countering childhood anemia and it may be beneficial to target future public health actions towards disadvantageous castes in India.
Oral Sucrose for Pain Relief During Clubfoot Casting: A Double-Blinded Randomized Controlled Trial.
Milbrandt, Todd; Kryscio, Richard; Muchow, Ryan; Walker, Janet; Talwalkar, Vishwas; Iwinski, Henry
2016-09-15
Idiopathic clubfoot treatment is treated by manipulation and casting utilizing the Ponseti technique which can make the infant fussy and irritable. The goal of this study was to determine which intervention could decrease this pain response in infants undergoing Ponseti casting for idiopathic clubfeet. Our hypothesis was that the administration of oral sucrose solution or milk would be the most effective in accomplishing that goal. We conducted a double-blinded randomized controlled trial at a tertiary pediatric orthopaedic center on 33 children (average age=17.94 d; SD=20.51 d) undergoing clubfoot manipulation and casting and their guardians. Each cast was considered a new event and was randomized to an oral 20% sucrose solution (S), water (W), or milk (M) in a bottle (breast or nonbreast). We assessed the Neonatal Infant Pain Scale (NIPS), heart rate, and oxygen saturation before, during, and after the casting. A total of 131 casts were randomized and 118 analyzed (37 M, 42 S, 39 W). Each child underwent an average of 3.97 casts (SD=1.74). There were no significant differences seen between the groups before casting in their mean NIPS score (M=2.2; SD=2.38, S=1.84, SD=2.18, W=1.61, SD=2.12). However during casting, mean NIPS score for both milk, 0.91 (SD=1.26, P=0.0005) and sucrose, 0.64 (SD=1.27, P<0.0001) were significantly less than water, 2.27 (SD=2.03) but not different from each other (P=0.33). Postcasting, the sucrose NIPS score, 0.69 (SD=1.53) continued to be significantly less than milk, 2.11 (SD=2.37, P=0.0065. There was no correlation between heart rate or oxygen saturation and NIPS. Sucrose solution and milk during Ponseti casting and manipulation were effective in decreasing the pain response in children undergoing manipulation and casting for clubfeet. The sucrose solution administration continued the pain relief into the postcasting period. In addition to the benefits of improving the patient experience during casting, a less irritable child may result in better casting. Level 1 evidence.
The role of serial casting in early-onset scoliosis (EOS).
Baulesh, David M; Huh, Jeannie; Judkins, Timothy; Garg, Sumeet; Miller, Nancy H; Erickson, Mark A
2012-01-01
Serial casting has demonstrated efficacy for idiopathic early-onset scoliosis (EOS). Results of casting in nonidiopathic (syndromic and congenital) EOS patients have not previously been well described. A total of 53 patients underwent serial casting for EOS from 2005 to 2010 at a single institution. Deformity was classified as idiopathic or nonidiopathic. Diagnosis, time in cast, number of casts, use of bracing, complications, and outcomes were recorded. Radiographic measures included Cobb angle and thoracic height (T1-T12). Thoracic height velocity was calculated and compared with established norms. A total of 36 patients, 19 idiopathic and 17 nonidiopathic (14 syndromic, 3 congenital), completed cast treatment and had >6-month follow-up and were therefore included. Of those, 17% (6/36) experienced resolution of their deformity, 53% (19/26) are currently in braces, and 31% (11/36) had undergone surgery. Surgery occurred on average at age 5.6 years and was delayed by an average of 2.1 years from time of first cast. A 19% complication was observed. There was no statistical difference in the rate of resolution of deformity between idiopathic (5/19) and nonidiopathic (1/17) patients (P=0.182), although there exists a trend toward greater curve correction in idiopathic patients. Surgery occurred in fewer patients (2/19) in the idiopathic group compared with the nonidiopathic group (9/17) (P=0.006). Significant improvements in Cobb angle was observed in the idiopathic group (12.2 degrees) during casting (P=0.003). Nonidiopathic patients did not maintain the correction gained during casting at the time of final follow-up. T1-T12 height increased across all study patients regardless of etiology during the period of casting at similar velocity to established norms of 1.4 cm/y for this age group. Serial casting offers modest deformity correction in idiopathic deformities compared with nonidiopathic deformities. Thoracic height growth continued throughout the casting period at normal velocity. Serial casting maintained normal longitudinal thoracic growth in all patients with EOS in this cohort. Although many required surgery, the increased thoracic height may have positive implications on ultimate pulmonary function. Therapeutic level III.
Coroian, Flavia; Jourdan, Claire; Froger, Jérome; Anquetil, Claire; Choquet, Olivier; Coulet, Bertand; Laffont, Isabelle
2017-05-01
To study the results and complications of percutaneous needle tenotomy for superficial retracted tendons in patients with brain damage. Prospective observational study. University hospital. Patients with severe brain damage (N=38; mean age, 60.7y; age range, 24-93y; 21 women) requiring surgical management of contractures and eligible for percutaneous needle tenotomy were enrolled between February 2015 and February 2016. The percutaneous needle tenotomy gesture was performed by a physical medicine and rehabilitation physician trained by an orthopedic surgeon, under local or locoregional anesthesia. Treated tendons varied among patients. All patients were evaluated at 1, 3, and 6 months to assess surgical outcomes (joint range of motion [ROM], pain, and functional improvement) while screening for complications. Improvements in ROM (37/38) and contractures-related pain (12/12) were satisfactory. Functional results were satisfactory (Goal Attainment Scale score ≥0) for most patients (37/38): nursing (n=12), putting shoes on (n=8), getting in bed or sitting on a chair (n=6), verticalization (n=7), transfers and gait (n=8), and grip (n=2). Five patients had complications related to the surgical gesture: cast-related complications (n=2), hand hematoma (n=2), and cutaneous necrosis of the Achilles tendon in a patient with previous obliterative arteriopathy of the lower limbs (n=1). Percutaneous needle tenotomy yields good results in the management of selected superficial muscle and tendon contractures. The complications rate is very low, and this treatment can be an alternative to conventional surgery in frail patients with neurologic diseases. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Marginal hepatectomy in the rat: from anatomy to surgery.
Madrahimov, Nodir; Dirsch, Olaf; Broelsch, Christoph; Dahmen, Uta
2006-07-01
Based on the 3-dimensional visualization of vascular supply and drainage, a vessel-oriented resection technique was optimized. The new surgical technique was used to determine the maximal reduction in liver mass enabling a 50% 1-week survival rate. Determination of the minimal liver mass is necessary in clinical as well as in experimental liver surgery. In rats, survival seems to depend on the surgical technique applied. Extended hepatectomy with removal of 90% of the liver mass was long regarded as a lethal model. Introduction of a vessel-oriented approach enabled long-term survival in this model. The lobar and vascular anatomy of rat livers was visualized by plastination of the whole organ, respectively, by corrosion casts of the portal vein, hepatic artery and liver veins. The three-dimensional models were used to extract the underlying anatomic structure. In 90% partial hepatectomy, the liver parenchyma was clamped close to the base of the respective liver lobes (left lateral, median and right, liver lobe). Piercing sutures were placed through the liver parenchyma, so that the stem of portal vein and the accompanying hepatic artery but also the hepatic vein were included. A 1-week survival rate of 100% was achieved after 90% hepatectomy. Extending the procedure to 95% resection by additional removal of the upper caudate lobe led to a 1-week survival rate of 66%; 97% partial hepatectomy, accomplished by additional resection of the lower caudate lobe only leaving the paracaval parts of the liver behind, resulted in 100% lethality within 4 days. Using a anatomically based, vessel-oriented, parenchyma-preserving surgical technique in 95% liver resections led to long-term survival. This represents the maximal reduction of liver mass compatible with survival.
Caste in 21st Century India: Competing Narratives
Desai, Sonalde; Dubey, Amaresh
2012-01-01
Recent debates regarding inclusion of caste in 2011 Census have raised questions about whether caste still matters in modern India. Ethnographic studies of the mid-20th century identified a variety of dimensions along which caste differentiation occurs. At the same time, whether this differentiation translates into hierarchy remains a contentious issue as does the persistence of caste, given the economic changes of the past two decades. Using data from a nationally representative survey of 41,554 households conducted in 2005, this paper examines the relationship between social background and different dimensions of well-being. The results suggest continued persistence of caste disparities in education, income and social networks. PMID:22736803
Parvatheesam, C; Babu, B V; Babu, M C
1997-01-01
The present study gives an account of the genetic structure in terms of distribution of a few genetic markers, viz., A1A2B0, Rh(D), G6PD deficiency and haemoglobin among the Rajaka caste population of Andhra Pradesh, India. The genetic relationships of the Rajaka caste with other Andhra caste populations were investigated in terms of genetic distance, i.e., Sq B (mn) of Balakrishnan and Sanghvi. Relatively lesser distance was established between the Rajaka and two Panchama castes. Also, the pattern of genetic distance corroborates the hierarchical order of the Hindu varna system.
Transmutation Fuel Fabrication-Fiscal Year 2016
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fielding, Randall Sidney; Grover, Blair Kenneth
ABSTRACT Nearly all of the metallic fuel that has been irradiated and characterized by the Advanced Fuel Campaign, and its earlier predecessors, has been arc cast. Arc casting is a very flexible method of casting lab scale quantities of materials. Although the method offers flexibility, it is an operator dependent process. Small changes in parameter space or alloy composition may affect how the material is cast. This report provides a historical insight in how the casting process has been modified over the history of the advanced fuels campaign as well as the physical parameters of the fuels cast in fiscalmore » year 2016.« less
A Recipe for Soft Fluidic Elastomer Robots
Marchese, Andrew D.; Katzschmann, Robert K.
2015-01-01
Abstract This work provides approaches to designing and fabricating soft fluidic elastomer robots. That is, three viable actuator morphologies composed entirely from soft silicone rubber are explored, and these morphologies are differentiated by their internal channel structure, namely, ribbed, cylindrical, and pleated. Additionally, three distinct casting-based fabrication processes are explored: lamination-based casting, retractable-pin-based casting, and lost-wax-based casting. Furthermore, two ways of fabricating a multiple DOF robot are explored: casting the complete robot as a whole and casting single degree of freedom (DOF) segments with subsequent concatenation. We experimentally validate each soft actuator morphology and fabrication process by creating multiple physical soft robot prototypes. PMID:27625913
A Recipe for Soft Fluidic Elastomer Robots.
Marchese, Andrew D; Katzschmann, Robert K; Rus, Daniela
2015-03-01
This work provides approaches to designing and fabricating soft fluidic elastomer robots. That is, three viable actuator morphologies composed entirely from soft silicone rubber are explored, and these morphologies are differentiated by their internal channel structure, namely, ribbed, cylindrical, and pleated. Additionally, three distinct casting-based fabrication processes are explored: lamination-based casting, retractable-pin-based casting, and lost-wax-based casting. Furthermore, two ways of fabricating a multiple DOF robot are explored: casting the complete robot as a whole and casting single degree of freedom (DOF) segments with subsequent concatenation. We experimentally validate each soft actuator morphology and fabrication process by creating multiple physical soft robot prototypes.
Microstructure and Corrosion Characterization of Squeeze Cast AM50 Magnesium Alloys
NASA Astrophysics Data System (ADS)
Sachdeva, Deepika; Tiwari, Shashank; Sundarraj, Suresh; Luo, Alan A.
2010-12-01
Squeeze casting of magnesium alloys potentially can be used in lightweight chassis components such as control arms and knuckles. This study documents the microstructural analysis and corrosion behavior of AM50 alloys squeeze cast at different pressures between 40 and 120 MPa and compares them with high-pressure die cast (HPDC) AM50 alloy castings and an AM50 squeeze cast prototype control arm. Although the corrosion rates of the squeeze cast samples are slightly higher than those observed for the HPDC AM50 alloy, the former does produce virtually porosity-free castings that are required for structural applications like control arms and wheels. This outcome is extremely encouraging as it provides an opportunity for additional alloy and process development by squeeze casting that has remained relatively unexplored for magnesium alloys compared with aluminum. Among the microstructural parameters analyzed, it seems that the β-phase interfacial area, indicating a greater degree of β network, leads to a lower corrosion rate. Weight loss was the better method for determining corrosion behavior in these alloys that contain a large fraction of second phase, which can cause perturbations to an overall uniform surface corrosion behavior.
Independent origins of Indian caste and tribal paternal lineages.
Cordaux, Richard; Aunger, Robert; Bentley, Gillian; Nasidze, Ivane; Sirajuddin, S M; Stoneking, Mark
2004-02-03
The origins of the nearly one billion people inhabiting the Indian subcontinent and following the customs of the Hindu caste system are controversial: are they largely derived from Indian local populations (i.e. tribal groups) or from recent immigrants to India? Archaeological and linguistic evidence support the latter hypothesis, whereas recent genetic data seem to favor the former hypothesis. Here, we analyze the most extensive dataset of Indian caste and tribal Y chromosomes to date. We find that caste and tribal groups differ significantly in their haplogroup frequency distributions; caste groups are homogeneous for Y chromosome variation and more closely related to each other and to central Asian groups than to Indian tribal or any other Eurasian groups. We conclude that paternal lineages of Indian caste groups are primarily descended from Indo-European speakers who migrated from central Asia approximately 3,500 years ago. Conversely, paternal lineages of tribal groups are predominantly derived from the original Indian gene pool. We also provide evidence for bidirectional male gene flow between caste and tribal groups. In comparison, caste and tribal groups are homogeneous with respect to mitochondrial DNA variation, which may reflect the sociocultural characteristics of the Indian caste society.
Properties of a hybrid plaster-fibreglass cast
Charles, Mark N.; Yen, David
2000-01-01
Objective To examine the suitability of a plaster-fibreglass hybrid cast for orthopedic applications, comparing them to plaster of Paris (POP) and fibreglass constructs. Method Groups of 10 standardized hybrid, POP and fibreglass casts were studied. An Instron servo-hydraulic system was used to test the casts in 3-point bending and shear. Outcome measures Strength, stiffness, weight, thickness and cost of the 3 types of cast, and shear strength at the interface between the POP and fibreglass in the hybrid casts. Results The hybrid casts were twice as strong as the POP constructs, were stiffer and weighed 14% less but were thicker and cost 2.5 times more. They were almost as strong as and less than half the cost of the fibreglass constructs but were thicker, not as stiff, and weighed 42% more. The shear strength of the POP–fibreglass interface in the hybrid casts was higher than the 3-point bending strength of this construct by a factor of 3. Conclusions Plaster-fibreglass hybrid casts should be considered for orthopedic use on the basis of their strength, stiffness, weight and cost, combined with their acknowledged advantages of good moulding ability and water resistance. PMID:11045095
Short-term after-effect of forearm cast removal in children.
Katz, Kalman; Weigl, Daniel; Becker, Tal; Attias, Joseph; Bar-On, Elhanan
2011-05-01
To investigate the sensation in the hand after forearm cast removal in children. The study group included 33 consecutive children who were treated nonoperatively for a forearm fracture at our center over a 1-year period. The children were asked to report any sensation in the ipsilateral hand after cast removal, and the findings were analyzed against background and fracture-related data. The patients ranged in age from 6 to 14 years (median 10.00 years). Seventeen had been immobilized in an above-elbow cast and the remainder in a below-elbow cast. All children treated with an above-elbow cast complained that after cast removal, the hand on that side felt limp, and they had to hold it with the contralateral hand. By contrast, only one child treated with a below-elbow cast reported this sensation (p = 0.0001, Fisher exact test). Orthopedic surgeons and rehabilitation unit staff should be aware of the possibility of a very short-term sensation of drooping and weakness of the hand after removal of an above-elbow cast in children and prepare the child and parents accordingly in order to lessen unnecessary anxiety.
Comparative study on stiffness properties of WOODCAST and conventional casting materials.
Pirhonen, Eija; Pärssinen, Antti; Pelto, Mika
2013-08-01
Plaster-of-Paris and synthetic materials (e.g. fibreglass) have been in clinical use as casting materials for decades. An innovative casting material, WOODCAST, brings interesting alternatives to the traditional materials. The aim of this study was to compare the stiffness properties of the WOODCAST material to traditional casting materials. In immobilization by casting, materials with variable stiffness properties are required. Ring stiffness of cylindrical samples correlates well with cast rigidity. For load-bearing structures, the use of the WOODCAST Splint is recommended as equally high stiffness was obtained with the WOODCAST Splint as was with fibreglass. The WOODCAST 2 mm product is optimal for structures where some elasticity is required, and WOODCAST Ribbon can be used in any WOODCAST structure where further reinforcement is needed. The results show that WOODCAST material can be used in replacing traditional casting materials used in extremity immobilization. The mechanical properties of casting material play an important role in safe and effective fracture immobilization. Stiffness properties of the WOODCAST casting material and conventional materials - fibreglass and plaster-of-Paris - were analysed in this study. The WOODCAST Splint appears to compare favorably with traditional materials such as Scotchcast.
Tannamala, Pavan Kumar; Azhagarasan, Nagarasampatti Sivaprakasam; Shankar, K Chitra
2013-01-01
Conventional casting techniques following the manufacturers' recommendations are time consuming. Accelerated casting techniques have been reported, but their accuracy with base metal alloys has not been adequately studied. We measured the vertical marginal gap of nickel-chromium copings made by conventional and accelerated casting techniques and determined the clinical acceptability of the cast copings in this study. Experimental design, in vitro study, lab settings. Ten copings each were cast by conventional and accelerated casting techniques. All copings were identical, only their mold preparation schedules differed. Microscopic measurements were recorded at ×80 magnification on the perpendicular to the axial wall at four predetermined sites. The marginal gap values were evaluated by paired t test. The mean marginal gap by conventional technique (34.02 μm) is approximately 10 μm lesser than that of accelerated casting technique (44.62 μm). As the P value is less than 0.0001, there is highly significant difference between the two techniques with regard to vertical marginal gap. The accelerated casting technique is time saving and the marginal gap measured was within the clinically acceptable limits and could be an alternative to time-consuming conventional techniques.
Rough case-based reasoning system for continues casting
NASA Astrophysics Data System (ADS)
Su, Wenbin; Lei, Zhufeng
2018-04-01
The continuous casting occupies a pivotal position in the iron and steel industry. The rough set theory and the CBR (case based reasoning, CBR) were combined in the research and implementation for the quality assurance of continuous casting billet to improve the efficiency and accuracy in determining the processing parameters. According to the continuous casting case, the object-oriented method was applied to express the continuous casting cases. The weights of the attributes were calculated by the algorithm which was based on the rough set theory and the retrieval mechanism for the continuous casting cases was designed. Some cases were adopted to test the retrieval mechanism, by analyzing the results, the law of the influence of the retrieval attributes on determining the processing parameters was revealed. A comprehensive evaluation model was established by using the attribute recognition theory. According to the features of the defects, different methods were adopted to describe the quality condition of the continuous casting billet. By using the system, the knowledge was not only inherited but also applied to adjust the processing parameters through the case based reasoning method as to assure the quality of the continuous casting and improve the intelligent level of the continuous casting.
Aali, Mohsen; Moradi-Shahrbabak, Mohammad; Moradi-Shahrbabak, Hosein; Sadeghi, Mostafa
2014-03-01
Calpastatin has been introduced as a potential candidate gene for growth and meat quality traits. In this study, genetic variability was investigated in the exon 6 and its intron boundaries of ovine CAST gene by PCR-SSCP analysis and DNA sequencing. Also a protein sequence and structural analysis were performed to predict the possible impact of amino acid substitutions on physicochemical properties and structure of the CAST protein. A total of 487 animals belonging to four ancient Iranian sheep breeds with different fat metabolisms, Lori-Bakhtiari and Chall (fat-tailed), Zel-Atabay cross-bred (medium fat-tailed) and Zel (thin-tailed), were analyzed. Eight unique SSCP patterns, representing eight different sequences or haplotypes, CAST-1, CAST-2 and CAST-6 to CAST-11, were identified. Haplotypes CAST-1 and CAST-2 were most common with frequency of 0.365 and 0.295. The novel haplotype CAST-8 had considerable frequency in Iranian sheep breeds (0.129). All the consensus sequences showed 98-99%, 94-98%, 92-93% and 82-83% similarity to the published ovine, caprine, bovine and porcine CAST locus sequences, respectively. Sequence analysis revealed four SNPs in intron 5 (C24T, G62A, G65T and T69-) and three SNPs in exon 6 (c.197A>T, c.282G>T and c.296C>G). All three SNPs in exon 6 were missense mutations which would result in p.Gln 66 Leu, p.Glu 94 Asp and p.Pro 99 Arg substitutions, respectively, in CAST protein. All three amino acid substitutions affected the physicochemical properties of ovine CAST protein including hydrophobicity, amphiphilicity and net charge and subsequently might influence its structure and effect on the activity of Ca2+ channels; hence, they might regulate calpain activity and afterwards meat tenderness and growth rate. The Lori-Bakhtiari population showed the highest heterozygosity in the ovine CAST locus (0.802). Frequency difference of haplotypes CAST-10 and CAST-8 between Lori-Bakhtiari (fat-tailed) and Zel (thin-tailed) breeds was highly significant (P<0.001), indicating that these two haplotypes might be breed-specific haplotypes that distinguish between fat-tailed and thin-tailed sheep breeds. Copyright © 2013 Elsevier B.V. All rights reserved.
[A surface reacted layer study of titanium-zirconium alloy after dental casting].
Zhang, Y; Guo, T; Li, Z; Li, C
2000-10-01
To investigate the influence of the mold temperature on the surface reacted layer of Ti-Zr alloy castings. Ti-Zr alloy was casted into a mold which was made of a zircon (ZrO2.SiO2) for inner coating and a phosphate-bonded material for outer investing with a casting machine (China) designed as vacuum, pressure and centrifuge. At three mold temperatures (room temperature, 300 degrees C, 600 degrees C) the Ti-Zr alloy was casted separately. The surface roughness of the castings was calculated by instrument of smooth finish (China). From the surface to the inner part the Knoop hardness and thickness in reacted layer of Ti-Zr alloy casting was measured. The structure of the surface reacted layer was analysed by SEM. Elemental analyses of the interfacial zone of the casting was made by element line scanning observation. The surface roughness of the castings was increased significantly with the mold temperature increasing. At a higher mold temperature the Knoop hardness of the reactive layer was increased. At the three mold temperature the outmost surface was very hard, and microhardness data decreased rapidly where they reached constant values. The thickness was about 85 microns for castings at room temperature and 300 degrees C, 105 microns for castings at 600 degrees C. From the SEM micrograph of the Ti-Zr alloy casting, the surface reacted layer could be divided into three different layers. The first layer was called non-structure layer, which thickness was about 10 microns for room temperature group, 20 microns for 300 degrees C and 25 microns for 600 degrees C. The second layer was characterized by coarse-grained acicular crystal, which thickness was about 50 microns for three mold temperatures. The third layer was Ti-Zr alloy. The element line scanning showed non-structure layer with higher level of element of O, Al, Si and Zr, The higher the mold temperature during casting, the deeper the Si permeating and in the second layer the element Si could also be found. The mold temperature is one of the major factors influencing to casting quality. In order to reduce the surface reacted layer of Ti-Zr alloy castings, the lower mold temperature and the investment without Si should be chosen.
75 FR 49945 - Iron Construction Castings From Brazil, Canada, and China
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-16
... Review)] Iron Construction Castings From Brazil, Canada, and China AGENCY: United States International... and antidumping duty orders on iron construction castings from Brazil, Canada, and China. SUMMARY: The... duty and or antidumping duty orders on iron construction castings from Brazil, Canada, and China would...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-14
...CAST AGENCY: Federal Emergency Management Agency, DHS. ACTION: Notice. SUMMARY: The Federal Emergency...CAST) (formerly known as the National Incident Management System Compliance Assistance Support Tool (NIMSCAST)). PrepCAST is a self-assessment tool for State, territorial, Tribal, and local governments to...
40 CFR 464.25 - Pretreatment standards for existing sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) EFFLUENT GUIDELINES AND STANDARDS METAL MOLDING AND CASTING POINT SOURCE CATEGORY Copper Casting... existing sources. (a) Casting Quench Operations. PSES Pollutant or pollutant property Maximum for any 1 day... monitoring) 1.2 0.399 (b) Direct Chill Casting Operations. PSES Pollutant or pollutant property Maximum for...
Application of TRIZ Theory in Patternless Casting Manufacturing Technique
NASA Astrophysics Data System (ADS)
Yang, Weidong; Gan, Dequan; Jiang, Ping; Tian, Yumei
The ultimate goal of Patternless Casting Manufacturing (referred to as PCM) is how to obtain the casts by casting the sand mold directly. In the previous PCM, the resin content of sand mold is much higher than that required by traditional resin sand, so the casts obtained are difficult to be sound and qualified products, which limits the application of this technique greatly. In this paper, the TRIZ algorithm is introduced to the innovation process in PCM systematically.
Report on results of current and future metal casting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Unal, Cetin; Carlson, Neil N.
2015-09-28
New modeling capabilities needed to simulate the casting of metallic fuels are added to Truchas code. In this report we summarize improvements we made in FY2015 in three areas; (1) Analysis of new casting experiments conducted with BCS and EFL designs, (2) the simulation of INL’s U-Zr casting experiments with Flow3D computer program, (3) the implementation of surface tension model into Truchas for unstructured mesh required to run U-Zr casting.
The ToxCast Chemical Landscape - Paving the Road to 21st ...
The ToxCast high-throughput screening (HTS) program within the U.S. Environmental Protection Agency (EPA) was launched in 2007. Phase I of the program screened 310 chemicals, mostly pesticides, across hundreds of ToxCast assay endpoints. In Phase II, the ToxCast library was expanded to 1878 chemicals, culminating in public release of screening data at the end of 2013. Concurrently, a larger EPA library of 3726 chemicals (including the Phase II chemicals) was undergoing screening in the cross-federal agency Tox21 HTS project. Four years later, Phase III of EPA’s ToxCast program is actively screening a diverse library consisting of more than 3800 chemicals, 96% of which are also undergoing Tox21 screening. The majority of ToxCast studies, to date, have focused on using HTS results to build biologically based models for predicting in vivo toxicity endpoints. The focus of the present article, in contrast, is on the EPA chemical library underpinning these efforts. A history of the phased construction of EPA’s ToxCast library is presented, considering factors influencing chemical selection as well as the various quality measures implemented. Next, Chemical Abstracts Service Registry Numbers (CASRN), which were used to compile initial chemical nominations for ToxCast testing, are used to assess overlaps of the current ToxCast library with important toxicity, regulatory, and exposure inventories. Lastly, ToxCast chemicals are described in terms of generaliz
Jadhav, Vivek Dattatray; Motwani, Bhagwan K; Shinde, Jitendra; Adhapure, Prasad
2017-01-01
The aim of this study was to evaluate the marginal fit and surface roughness of complete cast crowns made by a conventional and an accelerated casting technique. This study was divided into three parts. In Part I, the marginal fit of full metal crowns made by both casting techniques in the vertical direction was checked, in Part II, the fit of sectional metal crowns in the horizontal direction made by both casting techniques was checked, and in Part III, the surface roughness of disc-shaped metal plate specimens made by both casting techniques was checked. A conventional technique was compared with an accelerated technique. In Part I of the study, the marginal fit of the full metal crowns as well as in Part II, the horizontal fit of sectional metal crowns made by both casting techniques was determined, and in Part III, the surface roughness of castings made with the same techniques was compared. The results of the t -test and independent sample test do not indicate statistically significant differences in the marginal discrepancy detected between the two casting techniques. For the marginal discrepancy and surface roughness, crowns fabricated with the accelerated technique were significantly different from those fabricated with the conventional technique. Accelerated casting technique showed quite satisfactory results, but the conventional technique was superior in terms of marginal fit and surface roughness.
NASA Technical Reports Server (NTRS)
Misra, M. S.; Lemeshewsky, S.; Bolstad, D.
1982-01-01
The Ti-5Al-2.5Sn extremely low interstitial alloy employed in the large castings which form the critical attachment fittings of the Space Shuttle External Tank was selected because of its high fracture resistance at cryogenic temperatures. Casting was selected over alternative fabrication methods because of its lower cost and adaptability to design changes, although it was found necessary to weld-repair surface and subsurface casting defects in order to reduce the scrap rate and maintain the inherent cost advantage of the castings. Hot Isostatic Pressing was experimentally found to heal the surface and internal defects of the castings, but did not improve tensile or fracture properties and was therefore rejected as a production technique. Production castings are instead weld-repaired, without any mechanical property degradation.
Method and mold for casting thin metal objects
Pehrson, Brandon P; Moore, Alan F
2014-04-29
Provided herein are various embodiments of systems for casting thin metal plates and sheets. Typical embodiments include layers of mold cavities that are oriented vertically for casting the metal plates. In some embodiments, the mold cavities include a beveled edge such that the plates that are cast have a beveled edge. In some embodiments, the mold cavities are filled with a molten metal through an open horizontal edge of the cavity. In some embodiments, the mold cavities are filled through one or more vertical feed orifices. Further disclosed are methods for forming a thin cast metal plate or sheet where the thickness of the cast part is in a range from 0.005 inches to 0.2 inches, and the surface area of the cast part is in a range from 16 square inches to 144 square inches.
Method for casting thin metal objects
Pehrson, Brandon P; Moore, Alan F
2015-04-14
Provided herein are various embodiments of systems for casting thin metal plates and sheets. Typical embodiments include layers of mold cavities that are oriented vertically for casting the metal plates. In some embodiments, the mold cavities include a beveled edge such that the plates that are cast have a beveled edge. In some embodiments, the mold cavities are filled with a molten metal through an open horizontal edge of the cavity. In some embodiments, the mold cavities are filled through one or more vertical feed orifices. Further disclosed are methods for forming a thin cast metal plate or sheet where the thickness of the cast part is in a range from 0.005 inches to 0.2 inches, and the surface area of the cast part is in a range from 16 square inches to 144 square inches.
Cause and Prevention of Explosions Involving DC Casting of Aluminum Sheet Ingot
NASA Astrophysics Data System (ADS)
Richter, Ray T.; Ekenes, J. Martin
The casting of aluminum alloy sheet ingot and T-bar presents the potential for some of the most volatile situations that can occur in DC (direct chill) and EMC (Electromagnetic) casting processes. Aluminum Association explosion incident data from over 300 explosions spanning a twenty-year period were reviewed and analyzed looking for common factors and repetitive reasons for explosions. Analysis of explosions occurring during the three stages of sheet ingot casting, `start of cast', `steady state' and `end of cast', were examined and prioritized. Case studies illustrate the need for understanding both technical and non-technical factors contributing to explosions involving molten metal. This paper identifies the major causes of explosions involving DC casting of aluminum alloy sheet ingot and makes recommendations for how to prevent the recurrence of such events and minimize the risk of injury.
Optimization of Squeeze Casting for Aluminum Alloy Parts
DOE Office of Scientific and Technical Information (OSTI.GOV)
David Schwam; John F. Wallace; Qingming Chang
2002-07-30
This study was initiated with the installation of a new production size UBE 350 Ton VSC Squeeze Casting system in the Metal Casting Laboratory at Case Western University. A Lindberg 75k W electrical melting furnace was installed alongside. The challenge of installation and operation of such industrial-size equipment in an academic environment was met successfully. Subsequently, a Sterling oil die heater and a Visi-Track shot monitoring system were added. A significant number of inserts were designed and fabricated over the span of the project, primarily for squeeze casting different configurations of test bars and plates. A spiral ''ribbon insert'' formore » evaluation of molten metal fluidity was also fabricated. These inserts were used to generate a broad range of processing conditions and determine their effect on the quality of the squeeze cast parts. This investigation has studied the influence of the various casting variables on the quality of indirect squeeze castings primarily of aluminum alloys. The variables studied include gating design, fill time and fill patter, metal pressure and die temperature variations. The quality of the die casting was assessed by an analysis of both their surface condition and internal soundness. The primary metal tested was an aluminum 356 alloy. In addition to determining the effect of these casting variables on casting quality as measured by a flat plate die of various thickness, a number of test bar inserts with different gating designs have been inserted in the squeeze casting machine. The mechanical properties of these test bars produced under different squeeze casting conditions were measured and reported. The investigation of the resulting properties also included an analysis of the microstructure of the squeeze castings and the effect of the various structural constituents on the resulting properties. The main conclusions from this investigation are as follows: The ingate size and shape are very important since it must remain open until the casting is solidified and pressure is maintained on the solidifying casting. Fanned gates, particularly on the smaller section castings avoid jetting effects at the ingate end. The fan type ingate helps accomplish a rapid fill without high velocities. The molten metal has to fill the cavity before localized solidification occurs. This is best accomplished with a larger ingate to attain rapid filling without excessive velocity or jetting that occurs at high metal velocities. Straight gates are prone to case jetting of the metal stream even a low velocities. Fanned gates allow use of higher fill velocity without excessive jetting. A higher metal pressure provides a more complete fill of the die including improved compensation for solidification shrinkage. With the proper filling pattern, ingates, overflows and die temperature for a given die, very good tensile properties can be attained in squeeze casting. In general, the smaller squeeze castings require higher die temperatures. Computer models using the UES Procast and MagmaSoft finite element software can, after suitable adjustments, predict the flow pattern in the die cavity.« less
Data Package for Secondary Waste Form Down-Selection—Cast Stone
DOE Office of Scientific and Technical Information (OSTI.GOV)
Serne, R. Jeffrey; Westsik, Joseph H.
2011-09-05
Available literature on Cast Stone and Saltstone was reviewed with an emphasis on determining how Cast Stone and related grout waste forms performed in relationship to various criteria that will be used to decide whether a specific type of waste form meets acceptance criteria for disposal in the Integrated Disposal Facility (IDF) at Hanford. After the critical review of the Cast Stone/Saltstone literature, we conclude that Cast Stone is a good candidate waste form for further consideration. Cast stone meets the target IDF acceptance criteria for compressive strength, no free liquids, TCLP leachate are below the UTS permissible concentrations andmore » leach rates for Na and Tc-99 are suiteably low. The cost of starting ingredients and equipment necessary to generate Cast Stone waste forms with secondary waste streams are low and the Cast Stone dry blend formulation can be tailored to accommodate variations in liquid waste stream compositions. The database for Cast Stone short-term performance is quite extensive compared to the other three candidate waste solidification processes. The solidification of liquid wastes in Cast Stone is a mature process in comparison to the other three candidates. Successful production of Cast Stone or Saltstone has been demonstrated from lab-scale monoliths with volumes of cm3 through m3 sized blocks to 210-liter sized drums all the way to the large pours into vaults at Savannah River. To date over 9 million gallons of low activity liquid waste has been solidified and disposed in concrete vaults at Savannah River.« less
Updates on EPA’s High-Throughput Exposure Forecast (ExpoCast) Research Project (CPCP)
Recent research advances by the ORD ExpoCast project (CSS Rapid Exposure and Dosimetry) are presented to the computational toxicology community in the context of prioritizing chemicals on a risk-basis using joint ExpoCast and ToxCast predictions. Recent publications by Wambaugh e...
Casting copper to tungsten for high-power arc lamp cathodes
NASA Technical Reports Server (NTRS)
Will, H. A.
1974-01-01
Voids forming at interface when copper is cast onto tungsten can be eliminated by adding wetting agent during casting process. Small amount of copper and nickel are cast onto thoriated tungsten insert, insert is recast with more copper to form electrode. Good thermal conductance results in long-lived cathode.
75 FR 67395 - Iron Construction Castings From Brazil, Canada, and China; Determinations
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-02
... Review)] Iron Construction Castings From Brazil, Canada, and China; Determinations On the basis of the...), that revocation of the countervailing duty order on heavy iron construction castings from Brazil, the... iron construction castings (both heavy and light) from Brazil and China would be likely to lead to...
40 CFR 464.40 - Applicability; description of the zinc casting subcategory.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Applicability; description of the zinc... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS METAL MOLDING AND CASTING POINT SOURCE CATEGORY Zinc Casting Subcategory § 464.40 Applicability; description of the zinc casting subcategory. The provisions of this...
40 CFR 464.40 - Applicability; description of the zinc casting subcategory.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Applicability; description of the zinc... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS METAL MOLDING AND CASTING POINT SOURCE CATEGORY Zinc Casting Subcategory § 464.40 Applicability; description of the zinc casting subcategory. The provisions of this...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-12
... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-74,549] Algonac Cast Products... workers and former workers of Algonac Cast Products, Inc., Algonac, Michigan (subject firm) to apply for... Algonac Cast Products, Inc., Algonac, Michigan. Conclusion After careful review of the additional facts...
40 CFR 464.16 - Pretreatment standards for new sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... GUIDELINES AND STANDARDS METAL MOLDING AND CASTING POINT SOURCE CATEGORY Aluminum Casting Subcategory § 464... CFR part 403 and achieve the following pretreatment standards for new sources. (a) Casting Cleaning...) 0.114 0.0431 (b) Casting Quench Operations. PSNS Pollutant or pollutant property Maximum for any 1...
40 CFR 464.26 - Pretreatment standards for new sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... GUIDELINES AND STANDARDS METAL MOLDING AND CASTING POINT SOURCE CATEGORY Copper Casting Subcategory § 464.26... and achieve the following pretreatment standards for new sources. (a) Casting Quench Operations. PSNS... 0.0335 0.0109 Oil and grease (for alternate monitoring) 1.2 0.399 (b) Direct Chill Casting...
The Ins and Outs of Relief Casting.
ERIC Educational Resources Information Center
Greene, Yvonne
2000-01-01
Describes a unit on clay casting that introduces students to relief sculpture. The unit takes three 45 to 50 minute class periods three weeks apart. Discusses each class session in detail: (1) creating the casting; (2) turning out and rinsing the casting; and (3) enriching the surface with color. (CMK)
40 CFR 464.15 - Pretreatment standards for existing sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) EFFLUENT GUIDELINES AND STANDARDS METAL MOLDING AND CASTING POINT SOURCE CATEGORY Aluminum Casting... existing sources. (a) Casting Cleaning Operations. PSES Pollutant or pollutant property Maximum for any 1....0771 0.0421 Lead (T) 0.0791 0.039 Zinc (T) 0.114 0.0431 (b) Casting Quench Operation. PSES Pollutant or...
49 CFR 192.755 - Protecting cast-iron pipelines.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 3 2010-10-01 2010-10-01 false Protecting cast-iron pipelines. 192.755 Section... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.755 Protecting cast-iron pipelines. When an operator has knowledge that the support for a segment of a buried cast-iron...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-14
..., PrepCAST. AGENCY: Federal Emergency Management Agency, DHS. ACTION: Notice. SUMMARY: The Federal... . SUPPLEMENTARY INFORMATION: Collection of Information Title: PrepCAST. Type of information collection: Revision.... Abstract: PrepCAST is a collection instrument that will collect preparedness information at the State...
40 CFR 721.10667 - Slimes and sludges, aluminum and iron casting, wastewater treatment, solid waste.
Code of Federal Regulations, 2014 CFR
2014-07-01
... casting, wastewater treatment, solid waste. 721.10667 Section 721.10667 Protection of Environment... iron casting, wastewater treatment, solid waste. (a) Chemical substance and significant new uses... and iron casting, wastewater treatment, solid waste (PMN P-12-560; CAS No. 1391739-82-4; chemical...
40 CFR 721.10667 - Slimes and sludges, aluminum and iron casting, wastewater treatment, solid waste.
Code of Federal Regulations, 2013 CFR
2013-07-01
... casting, wastewater treatment, solid waste. 721.10667 Section 721.10667 Protection of Environment... iron casting, wastewater treatment, solid waste. (a) Chemical substance and significant new uses... and iron casting, wastewater treatment, solid waste (PMN P-12-560; CAS No. 1391739-82-4; chemical...
The ToxCast Chemical Landscape - Paving the Road to 21st Century Toxicology
The ToxCast high-throughput screening (HTS) program within the U.S. Environmental Protection Agency (EPA) was launched in 2007. Phase I of the program screened 310 chemicals, mostly pesticides, across hundreds of ToxCast assay endpoints. In Phase II, the ToxCast library was exp...
... a waterproof plastic cast protector instead of plastic bags. You can buy this at a drugstore. Keep the cast completely out of the water by propping it up on the side of the tub. If the cast or liner gets splashed, gently blow air into it from a hair dryer on the ...
21 CFR 888.5940 - Cast component.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cast component. 888.5940 Section 888.5940 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... the cast heel, toe cap, cast support, and walking iron. (b) Classification. Class I (general controls...
21 CFR 888.5940 - Cast component.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cast component. 888.5940 Section 888.5940 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... the cast heel, toe cap, cast support, and walking iron. (b) Classification. Class I (general controls...
Onyx extrusion through the scalp after embolization of dural arteriovenous fistula.
Singla, Amit; Fargen, Kyle Michael; Hoh, Brian
2015-07-28
A man in his sixties referred with symptoms of episodic left lip numbness and left arm weakness was diagnosed with a Borden type 3 dural arteriovenous fistula (DAVF) on DSA. Successful Onyx embolization of the DAVF was performed via the distal left occipital artery using an ev3 Apollo detachable tip microcatheter. He underwent surgical obliteration for the residual DAVF 3 days later. Three months later during a routine postoperative clinic visit, the patient produced a plastic bag containing multiple small pieces of Onyx cast and the detached tip of the Apollo microcatheter that had extruded out from his scalp through small spontaneous holes about 5 weeks after the embolization procedure. This spontaneous extrusion of Onyx can be alarming to the patient not expecting it; however, prior knowledge and discussion can lessen the anxiety of both the treating physician and the patient dealing with such a situation. 2015 BMJ Publishing Group Ltd.
Onyx extrusion through the scalp after embolization of dural arteriovenous fistula
Singla, Amit; Fargen, Kyle Michael; Hoh, Brian
2015-01-01
A man in his sixties referred with symptoms of episodic left lip numbness and left arm weakness was diagnosed with a Borden type 3 dural arteriovenous fistula (DAVF) on DSA. Successful Onyx embolization of the DAVF was performed via the distal left occipital artery using an ev3 Apollo detachable tip microcatheter. He underwent surgical obliteration for the residual DAVF 3 days later. Three months later during a routine postoperative clinic visit, the patient produced a plastic bag containing multiple small pieces of Onyx cast and the detached tip of the Apollo microcatheter that had extruded out from his scalp through small spontaneous holes about 5 weeks after the embolization procedure. This spontaneous extrusion of Onyx can be alarming to the patient not expecting it; however, prior knowledge and discussion can lessen the anxiety of both the treating physician and the patient dealing with such a situation. PMID:26220981
Oetgen, Matthew E; Peden, Sean
2012-05-01
Toe walking is a bilateral gait abnormality in which a normal heel strike is absent and most weight bearing occurs through the forefoot. This abnormality may not be pathologic in patients aged <2 years, but it is a common reason for referral to an orthopaedic surgeon. Toe walking can be caused by several neurologic and developmental abnormalities and may be the first sign of a global developmental problem. Cases that lack a definitive etiology are categorized as idiopathic. A detailed history, with careful documentation of the developmental history, and a thorough physical examination are required in the child with a primary report of toe walking. Treatment is based on age and the severity of the abnormality. Management includes observation, stretching, casting, bracing, chemodenervation, and surgical lengthening of the gastrocnemius-soleus complex and/or Achilles tendon. An understanding of idiopathic toe walking as well as treatment options and their outcomes can help the physician individualize treatment to achieve optimal results.
NASA Astrophysics Data System (ADS)
Anderson, Mark; Bruski, Richard; Groszkiewicz, Daniel; Wagstaff, Bob
A new Direct Chill (DC) casting process is introduced to semi-continuous casting where near net shaped ingots are solidified. This process is currently being used at Alcan Engineered Cast Products (ECP) facility in Jonquiere, Canada, sectioned, then forged at Alcoa Automotive, Kentucky Casting Center (KCC). Finished forgings are machined and assembled into the Ford D/EW98 platform as suspension components. A brief description of the process and the implications on the forging process are presented.
1981-07-01
C’, and at temperature T, are Infiltrated by !L amougt of liquid of composition C’., such that ,C, 4 f+.C’L - X. V. 7 average carbon content of the...maximum liquid penetration was 100 mm at an infiltration pressure of 755 kPa. The average casting composition was 0.94 w/o carbon . The segregation at...content* at four casting locations. 2. Results The casting composition ( carbon content) as a function of casting location is given in Table D-IV. The
The role of water in slip casting
NASA Technical Reports Server (NTRS)
Mccauley, R. A.; Phelps, G. W.
1984-01-01
Slips and casting are considered in terms of physical and colloidal chemistry. Casting slips are polydisperse suspensions of lyophobic particles in water, whose degree of coagulation is controlled by interaction of flocculating and deflocculating agents. Slip casting rate and viscosity are functions of temperature. Slip rheology and response to deflocculating agents varies significantly as the kinds and amounts of colloid modifiers change. Water is considered as a raw material. Various concepts of water/clay interactions and structures are discussed. Casting is a de-watering operation in which water moves from slip to cast to mold in response to a potential energy termed moisture stress. Drying is an evaporative process from a free water surface.
Research of Mechanical Property Gradient Distribution of Al-Cu Alloy in Centrifugal Casting
NASA Astrophysics Data System (ADS)
Sun, Zhi; Sui, Yanwei; Liu, Aihui; Li, Bangsheng; Guo, Jingjie
Al-Cu alloy castings are obtained using centrifugal casting. The regularity of mechanical property gradient distribution of Al-Cu alloy castings with the same centrifugal radius at different positions is investigated. The result shows that the tensile strength, yield strength, elongation and microscope hardness exhibit the following gradient distribution characteristic — high on both sides and low on the center. The trend of mechanical property gradient distribution of Al-Cu alloy increases with the increase in the rotation speed. Moreover, the mechanical properties of casting centerline two sides have asymmetry. The reason is that the grain size of casting centerline two sides and Al2Cu phase and Cu content change correspondingly.
ICAM Manufacturing Cost/Design Guide. Volume 3. Airframes. User’s Manual.
1983-01-01
COST-DRIVER EFFECT 17 -413H Investment Cast 17 - 4PH Investment Cast 2 2 - U) *oo 0±0.01 ±0.02 ±0.03 0±0.01 ±0.02 ±0.03 356iA356 Aluminum 356/A356...B +20% CAST B +50% 17 - 4PH CRES DORC BASE INVESTMENT D OR C WITH 10% B +20% CAST D OR C WITH 50% B +30% B +60% NOTE: X-Ray Grade A Is an Impractical...per QQ-A-601 (sand castings) - 357 per MIL-A-21180 (sand castings) a Steel - 17 - 4PH CRES per AMS-5342, 5343, and 5344 or * company equivalent
Effect of carbon content on friction and wear of cast irons
NASA Technical Reports Server (NTRS)
Buckley, D. H.
1977-01-01
Friction and wear experiments were conducted with cast irons and wrought steels containing various amounts of carbon in the alloy structure in contact with 52100 steel. Gray cast irons were found to exhibit lower friction and wear characteristics than white cast irons. Further, gray cast iron wear was more sensitive to carbon content than was white. Wear with gray cast iron was linearly related to load, and friction was found to be sensitive to relative humidity and carbon content. The form, in which the carbon is present in the alloy, is more important, as the carbon content and no strong relationship seems to exist between hardness of these ferrous alloys and wear.
An objective assessment of safety to drive in an upper limb cast.
Stevenson, H L; Peterson, N; Talbot, C; Dalal, S; Watts, A C; Trail, I A
2013-03-01
Patients managed with upper limb cast immobilization often seek advice about driving. There is very little published data to assist in decision making, and advice given varies between healthcare professionals. There are no specific guidelines available from the UK Drivers and Vehicles Licensing Agency, police, or insurance companies. Evidence-based guidelines would enable clinicians to standardize the advice given to patients. Six individuals (three male, three female; mean age 36 years, range 27-43 years) were assessed by a mobility occupational therapist and driving standards agency examiner while completing a formal driving test in six different types of upper limb casts (above-elbow, below-elbow neutral, and below-elbow cast incorporating the thumb [Bennett's cast]) on both left and right sides. Of the 36 tests, participants passed 31 tests, suggesting that most people were able to safely drive with upper limb cast immobilization. However, driving in a left above-elbow cast was considered unsafe.
NASA Technical Reports Server (NTRS)
2001-01-01
Howmet Research Corporation was the first to commercialize an innovative cast metal technology developed at Auburn University, Auburn, Alabama. With funding assistance from NASA's Marshall Space Flight Center, Auburn University's Solidification Design Center (a NASA Commercial Space Center), developed accurate nickel-based superalloy data for casting molten metals. Through a contract agreement, Howmet used the data to develop computer model predictions of molten metals and molding materials in cast metal manufacturing. Howmet Metal Mold (HMM), part of Howmet Corporation Specialty Products, of Whitehall, Michigan, utilizes metal molds to manufacture net shape castings in various alloys and amorphous metal (metallic glass). By implementing the thermophysical property data from by Auburn researchers, Howmet employs its newly developed computer model predictions to offer customers high-quality, low-cost, products with significantly improved mechanical properties. Components fabricated with this new process replace components originally made from forgings or billet. Compared with products manufactured through traditional casting methods, Howmet's computer-modeled castings come out on top.
In Situ Casting and Imaging of the Rat Airway Tree for Accurate 3D Reconstruction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacob, Rick E.; Colby, Sean M.; Kabilan, Senthil
The use of anatomically accurate, animal-specific airway geometries is important for understanding and modeling the physiology of the respiratory system. One approach for acquiring detailed airway architecture is to create a bronchial cast of the conducting airways. However, typical casting procedures either do not faithfully preserve the in vivo branching angles, or produce rigid casts that when removed for imaging are fragile and thus easily damaged. We address these problems by creating an in situ bronchial cast of the conducting airways in rats that can be subsequently imaged in situ using 3D micro-CT imaging. We also demonstrate that deformations inmore » airway branch angles resulting from the casting procedure are small, and that these angle deformations can be reversed through an interactive adjustment of the segmented cast geometry. Animal work was approved by the Institutional Animal Care and Use Committee of Pacific Northwest National Laboratory.« less
NASA Technical Reports Server (NTRS)
Mccay, M. H.
1988-01-01
The Casting and Solidification Technology (CAST) experiment will study the phenomena that occur during directional solidification of an alloy, e.g., constitutional supercooling, freckling, and dendrite coarsening. The reduced gravity environment of space will permit the individual phenomena to be examined with minimum complication from buoyancy driven flows.
49 CFR 192.489 - Remedial measures: Cast iron and ductile iron pipelines.
Code of Federal Regulations, 2011 CFR
2011-10-01
... for Corrosion Control § 192.489 Remedial measures: Cast iron and ductile iron pipelines. (a) General graphitization. Each segment of cast iron or ductile iron pipe on which general graphitization is found to a... 49 Transportation 3 2011-10-01 2011-10-01 false Remedial measures: Cast iron and ductile iron...
49 CFR 192.489 - Remedial measures: Cast iron and ductile iron pipelines.
Code of Federal Regulations, 2010 CFR
2010-10-01
... for Corrosion Control § 192.489 Remedial measures: Cast iron and ductile iron pipelines. (a) General graphitization. Each segment of cast iron or ductile iron pipe on which general graphitization is found to a... 49 Transportation 3 2010-10-01 2010-10-01 false Remedial measures: Cast iron and ductile iron...
40 CFR 464.40 - Applicability; description of the zinc casting subcategory.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Applicability; description of the zinc casting subcategory. 464.40 Section 464.40 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) METAL MOLDING AND CASTING POINT SOURCE CATEGORY Zinc Casting Subcategory § 464.40...
40 CFR 464.40 - Applicability; description of the zinc casting subcategory.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Applicability; description of the zinc casting subcategory. 464.40 Section 464.40 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) METAL MOLDING AND CASTING POINT SOURCE CATEGORY Zinc Casting Subcategory § 464.40...
40 CFR 464.40 - Applicability; description of the zinc casting subcategory.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Applicability; description of the zinc casting subcategory. 464.40 Section 464.40 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) METAL MOLDING AND CASTING POINT SOURCE CATEGORY Zinc Casting Subcategory § 464.40...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-05
... DEPARTMENT OF COMMERCE International Trade Administration [A-570-881] Malleable Cast Iron Pipe... antidumping duty order on malleable cast iron pipe fittings from the People's Republic of China (``PRC''). See... malleable cast iron pipe fittings from the PRC. See Initiation of Antidumping and Countervailing Duty...
46 CFR 153.239 - Use of cast iron.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Use of cast iron. 153.239 Section 153.239 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK... Systems § 153.239 Use of cast iron. (a) Cast iron used in a cargo containment system must meet the...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-10
... Castings Inc., a Subsidiary of WHEMCO, Including On-Site Leased Workers From Berkebile Excavating Company... Assistance on June 25, 2013, applicable to workers of Johnstown Specialty Castings, Inc., a subsidiary of... Castings, Inc., a subsidiary of WHEMCO. The Department has determined that these workers were sufficiently...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-14
... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-990 (Second Review)] Non-Malleable Cast... Duty Order on Non-Malleable Cast Iron Pipe Fittings From China AGENCY: United States International... determine whether revocation of the antidumping duty order on non-malleable cast iron pipe fittings from...
The use of porcine corrosion casts for teaching human anatomy.
Eberlova, Lada; Liska, Vaclav; Mirka, Hynek; Tonar, Zbynek; Haviar, Stanislav; Svoboda, Milos; Benes, Jan; Palek, Richard; Emingr, Michal; Rosendorf, Jachym; Mik, Patrik; Leupen, Sarah; Lametschwandtner, Alois
2017-09-01
In teaching and learning human anatomy, anatomical autopsy and prosected specimens have always been indispensable. However, alternative methods must often be used to demonstrate particularly delicate structures. Corrosion casting of porcine organs with Biodur E20 ® Plus is valuable for teaching and learning both gross anatomy and, uniquely, the micromorphology of cardiovascular, respiratory, digestive, and urogenital systems. Assessments of casts with a stereomicroscope and/or scanning electron microscope as well as highlighting cast structures using color coding help students to better understand how the structures that they have observed as two-dimensional images actually exist in three dimensions, and students found using the casts to be highly effective in their learning. Reconstructions of cast hollow structures from (micro-)computed tomography scans and videos facilitate detailed analyses of branching patterns and spatial arrangements in cast structures, aid in the understanding of clinically relevant structures and provide innovative visual aids. The casting protocol and teaching manual we offer can be adjusted to different technical capabilities and might also be found useful for veterinary or other biological science classes. Copyright © 2017 Elsevier GmbH. All rights reserved.
NASA Astrophysics Data System (ADS)
Jiang, Bo; Wu, Meng; Sun, He; Wang, Zhilin; Zhao, Zhigang; Liu, Yazheng
2018-01-01
The austenite growth behavior of non-quenched and tempered steels (casted by continuous casting and molding casting processes) was studied. The austenite grain size of steel B casted by continuous casting process is smaller than that of steel A casted by molding casting process at the same heating parameters. The abnormal austenite growth temperature of the steels A and B are 950 °C and 1000 °C, respectively. Based on the results, the models for the austenite grain growth below and above the abnormal austenite growth temperature of the investigated steels were established. The dispersedly distributed fine particles MnS in steel B is the key factor refining the austenite grain by pinning the migration of austenite grain boundary. The elongated inclusions MnS are ineffective in preventing the austenite grain growth at high heating temperature. For the non-quenched and tempered steel, the continuous casting process should be adopted and the inclusion MnS should be elliptical, smaller in size and distributed uniformly in order to refine the final microstructure and also improve the mechanical properties.
The Effect of Sr Modifier Additions on Double Oxide Film Defects in 2L99 Alloy Castings
NASA Astrophysics Data System (ADS)
Chen, Qi; Griffiths, W. D.
2017-11-01
In this paper, Sr modifier (300 ppm) was added to 2L99 alloy sand castings to investigate its effect on bifilm defects in the castings. Two different sand molds were used in this study, with good and bad running system designs, to introduce different amounts of bifilm defects into the castings. The mechanical properties of the modified 2L99 castings were compared to the properties of unmodified castings and showed that with high bifilm defect contents (H) the Sr addition reduced the Weibull modulus of the UTS by 67 pct and the Position Parameter by 5 pct, and introduced a bimodal distribution into the Weibull plot of the pct Elongation. However, for castings with low bifilm defect content (L), the Weibull moduli of both the UTS and pct Elongation were significantly improved (by 78 and 73 pct, respectively) with the addition of Sr. The Position Parameter of the pct Elongation was improved by 135 pct. The results suggested that a desirable modification effect can only be achieved while the bifilm defect content in a casting was low.
Glovebox Advanced Casting System Casting Optimization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fielding, Randall Sidney
2016-03-01
Casting optimization in the GACS included three broad areas; casting of U-10Zr pins, incorporation of an integral FCCI barrier, and development of a permanent crucible coating. U-10Zr casting was improved over last year’s results by modifying the crucible design to minimize contact with the colder mold. Through these modifications casting of a three pin batch was successful. Incorporation of an integral FCCI barrier also was optimized through furnace chamber pressure changes during the casting cycle to reduce gas pressures in the mold cavities which led to three full length pins being cast which incorporated FCCI barriers of three different thicknesses.more » Permanent crucible coatings were tested against a base case; 1500°C for 10 minutes in a U-20Pu-10Zr molten alloy. None of the candidate coating materials showed evidence of failure upon initial visual examination. In all areas of work a large amount of characterization will be needed to fully determine the effects of the optimization activities. The characterization activities and future work will occur next year.« less
Characterization and expression of the calpastatin gene in Cyprinus carpio.
Chen, W X; Ma, Y
2015-07-03
Calpastatin, an important protein used to regulate meat quality traits in animals, is encoded by the CAST gene. The aim of the present study was to clone the cDNA sequence of the CAST gene and detect the expression of CAST in the tissues of Cyprinus carpio. The cDNA of the C. carpio CAST gene, amplified using rapid amplification of cDNA ends PCR, is 2834 bp in length (accession No. JX275386), contains a 2634-bp open reading frame, and encodes a protein with 877 amino acid residues. The amino acid sequence of the C. carpio CAST gene was 88, 80, and 59% identical to the sequences observed in grass carp, zebrafish, and other fish, respectively. The C. carpio CAST was observed to contain four conserved domains with 54 serine phosphorylation loci, 28 threonine phosphorylation loci, 1 tyrosine phosphorylation loci, and 6 specific protein kinase C phosphorylation loci. The CAST gene showed widespread expression in different tissues of C. carpio. Surprisingly, the relative expression of the CAST transcript in the muscle and heart tissues of C. carpio was significantly higher than in other tissues (P < 0.01).
Bitar, KM; Ferdhany, ME; Saw, A
2016-01-01
Introduction: Hip spica casting is an important component of treatment for developmental dysplasia of the hip (DDH) and popular treatment method for femur fractures in children. Breakage at the hip region is a relatively common problem of this cast. We have developed a three-slab technique of hip spica application using fibreglass as the cast material. The purpose of this review was to evaluate the physical durability of the spica cast and skin complications with its use. Methodology: A retrospective review of children with various conditions requiring hip spica immobilisation which was applied using our method. Study duration was from 1st of January 2014 until 31st December 2015. Our main outcomes were cast breakage and skin complications. For children with hip instability, the first cast would be changed after one month, and the second cast about two months later. Results: Twenty-one children were included, with an average age of 2.2 years. The most common indication for spica immobilisation was developmental dysplasia of the hip. One child had skin irritation after spica application. No spica breakage was noted. Conclusion: This study showed that the three-slab method of hip spica cast application using fibreglass material was durable and safe with low risk of skin complications. PMID:28553442
Rowe, Philip
2013-01-01
Residual limb shape capturing (Casting) consistency has a great influence on the quality of socket fit. Magnetic Resonance Imaging was used to establish a reliable reference grid for intercast and intracast shape and volume consistency of two common casting methods, Hands-off and Hands-on. Residual limbs were cast for twelve people with a unilateral below knee amputation and scanned twice for each casting concept. Subsequently, all four volume images of each amputee were semiautomatically segmented and registered to a common coordinate system using the tibia and then the shape and volume differences were calculated. The results show that both casting methods have intra cast volume consistency and there is no significant volume difference between the two methods. Inter- and intracast mean volume differences were not clinically significant based on the volume of one sock criteria. Neither the Hands-off nor the Hands-on method resulted in a consistent residual limb shape as the coefficient of variation of shape differences was high. The resultant shape of the residual limb in the Hands-off casting was variable but the differences were not clinically significant. For the Hands-on casting, shape differences were equal to the maximum acceptable limit for a poor socket fit. PMID:24348164
Caste- and ethnicity-based inequalities in HIV/AIDS-related knowledge gap: a case of Nepal.
Atteraya, Madhu; Kimm, HeeJin; Song, In Han
2015-05-01
Caste- and ethnicity-based inequalities are major obstacles to achieving health equity. The authors investigated whether there is any association between caste- and ethnicity-based inequalities and HIV-related knowledge within caste and ethnic populations. They used the 2011 Nepal Demographic and Health Survey, a nationally represented cross-sectional study data set. The study sample consisted of 11,273 women between 15 and 49 years of age. Univariate and logistic regression models were used to examine the relationship between caste- and ethnicity-based inequalities and HIV-related knowledge. The study sample was divided into high Hindu caste (47.9 percent), "untouchable" caste (18.4 percent), and indigenous populations (33.7 percent). Within the study sample, the high-caste population was found to have the greatest knowledge of the means by which HIV is prevented and transmitted. After controlling for socioeconomic and demographic characteristics, untouchables were the least knowledgeable. The odds ratio for incomplete knowledge about transmission among indigenous populations was 1.27 times higher than that for high Hindu castes, but there was no significant difference in knowledge of preventive measures. The findings suggest the existence of a prevailing HIV knowledge gap. This in turn suggests that appropriate steps need to be implemented to convey complete knowledge to underprivileged populations.
Safari, Mohammad Reza; Rowe, Philip; McFadyen, Angus; Buis, Arjan
2013-01-01
Residual limb shape capturing (Casting) consistency has a great influence on the quality of socket fit. Magnetic Resonance Imaging was used to establish a reliable reference grid for intercast and intracast shape and volume consistency of two common casting methods, Hands-off and Hands-on. Residual limbs were cast for twelve people with a unilateral below knee amputation and scanned twice for each casting concept. Subsequently, all four volume images of each amputee were semiautomatically segmented and registered to a common coordinate system using the tibia and then the shape and volume differences were calculated. The results show that both casting methods have intra cast volume consistency and there is no significant volume difference between the two methods. Inter- and intracast mean volume differences were not clinically significant based on the volume of one sock criteria. Neither the Hands-off nor the Hands-on method resulted in a consistent residual limb shape as the coefficient of variation of shape differences was high. The resultant shape of the residual limb in the Hands-off casting was variable but the differences were not clinically significant. For the Hands-on casting, shape differences were equal to the maximum acceptable limit for a poor socket fit.
Bauer, José Roberto de Oliveira; Grande, Rosa Helena Miranda; Rodrigues-Filho, Leonardo Eloy; Pinto, Marcelo Mendes; Loguercio, Alessandro Dourado
2012-01-01
The aim of the present study was to evaluate the tensile strength, elongation, microhardness, microstructure and fracture pattern of various metal ceramic alloys cast under different casting conditions. Two Ni-Cr alloys, Co-Cr and Pd-Ag were used. The casting conditions were as follows: electromagnetic induction under argon atmosphere, vacuum, using blowtorch without atmosphere control. For each condition, 16 specimens, each measuring 25 mm long and 2.5 mm in diameter, were obtained. Ultimate tensile strength (UTS) and elongation (EL) tests were performed using a Kratos machine. Vickers Microhardness (VM), fracture mode and microstructure were analyzed by SEM. UTS, EL and VM data were statistically analyzed using ANOVA. For UTS, alloy composition had a direct influence on casting condition of alloys (Wiron 99 and Remanium CD), with higher values shown when cast with Flame/Air (p < 0.05). The factors 'alloy" and 'casting condition" influenced the EL and VM results, generally presenting opposite results, i.e., alloy with high elongation value had lower hardness (Wiron 99), and casting condition with the lowest EL values had the highest VM values (blowtorch). Both factors had significant influence on the properties evaluated, and prosthetic laboratories should select the appropriate casting method for each alloy composition to obtain the desired property.
Nurse forecasting in Europe (RN4CAST): Rationale, design and methodology
2011-01-01
Background Current human resources planning models in nursing are unreliable and ineffective as they consider volumes, but ignore effects on quality in patient care. The project RN4CAST aims innovative forecasting methods by addressing not only volumes, but quality of nursing staff as well as quality of patient care. Methods/Design A multi-country, multilevel cross-sectional design is used to obtain important unmeasured factors in forecasting models including how features of hospital work environments impact on nurse recruitment, retention and patient outcomes. In each of the 12 participating European countries, at least 30 general acute hospitals were sampled. Data are gathered via four data sources (nurse, patient and organizational surveys and via routinely collected hospital discharge data). All staff nurses of a random selection of medical and surgical units (at least 2 per hospital) were surveyed. The nurse survey has the purpose to measure the experiences of nurses on their job (e.g. job satisfaction, burnout) as well as to allow the creation of aggregated hospital level measures of staffing and working conditions. The patient survey is organized in a sub-sample of countries and hospitals using a one-day census approach to measure the patient experiences with medical and nursing care. In addition to conducting a patient survey, hospital discharge abstract datasets will be used to calculate additional patient outcomes like in-hospital mortality and failure-to-rescue. Via the organizational survey, information about the organizational profile (e.g. bed size, types of technology available, teaching status) is collected to control the analyses for institutional differences. This information will be linked via common identifiers and the relationships between different aspects of the nursing work environment and patient and nurse outcomes will be studied by using multilevel regression type analyses. These results will be used to simulate the impact of changing different aspects of the nursing work environment on quality of care and satisfaction of the nursing workforce. Discussion RN4CAST is one of the largest nurse workforce studies ever conducted in Europe, will add to accuracy of forecasting models and generate new approaches to more effective management of nursing resources in Europe. PMID:21501487
Nurse forecasting in Europe (RN4CAST): Rationale, design and methodology.
Sermeus, Walter; Aiken, Linda H; Van den Heede, Koen; Rafferty, Anne Marie; Griffiths, Peter; Moreno-Casbas, Maria Teresa; Busse, Reinhard; Lindqvist, Rikard; Scott, Anne P; Bruyneel, Luk; Brzostek, Tomasz; Kinnunen, Juha; Schubert, Maria; Schoonhoven, Lisette; Zikos, Dimitrios
2011-04-18
Current human resources planning models in nursing are unreliable and ineffective as they consider volumes, but ignore effects on quality in patient care. The project RN4CAST aims innovative forecasting methods by addressing not only volumes, but quality of nursing staff as well as quality of patient care. A multi-country, multilevel cross-sectional design is used to obtain important unmeasured factors in forecasting models including how features of hospital work environments impact on nurse recruitment, retention and patient outcomes. In each of the 12 participating European countries, at least 30 general acute hospitals were sampled. Data are gathered via four data sources (nurse, patient and organizational surveys and via routinely collected hospital discharge data). All staff nurses of a random selection of medical and surgical units (at least 2 per hospital) were surveyed. The nurse survey has the purpose to measure the experiences of nurses on their job (e.g. job satisfaction, burnout) as well as to allow the creation of aggregated hospital level measures of staffing and working conditions. The patient survey is organized in a sub-sample of countries and hospitals using a one-day census approach to measure the patient experiences with medical and nursing care. In addition to conducting a patient survey, hospital discharge abstract datasets will be used to calculate additional patient outcomes like in-hospital mortality and failure-to-rescue. Via the organizational survey, information about the organizational profile (e.g. bed size, types of technology available, teaching status) is collected to control the analyses for institutional differences.This information will be linked via common identifiers and the relationships between different aspects of the nursing work environment and patient and nurse outcomes will be studied by using multilevel regression type analyses. These results will be used to simulate the impact of changing different aspects of the nursing work environment on quality of care and satisfaction of the nursing workforce. RN4CAST is one of the largest nurse workforce studies ever conducted in Europe, will add to accuracy of forecasting models and generate new approaches to more effective management of nursing resources in Europe.
Labronici, Pedro José; Ferreira, Leonardo Termis; Dos Santos Filho, Fernando Claudino; Pires, Robinson Esteves Santos; Gomes, Davi Coutinho Fonseca Fernandes; da Silva, Luiz Henrique Penteado; Gameiro, Vinicius Schott
2017-02-01
Several so-called casting indices are available for objective evaluation of plaster cast quality. The present study sought to investigate four of these indices (gap index, padding index, Canterbury index, and three-point index) as compared to a reference standard (cast index) for evaluation of plaster cast quality after closed reduction of pediatric displaced distal forearm fractures. Forty-three radiographs from patients with displaced distal forearm fractures requiring manipulation were reviewed. Accuracy, sensitivity, specificity, false-positive probability, false-negative probability, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio were calculated for each of the tested indices. Comparison among indices revealed diagnostic agreement in only 4.7% of cases. The strongest correlation with the cast index was found for the gap index, with a Spearman correlation coefficient of 0.94. The gap index also displayed the best agreement with the cast index, with both indices yielding the same result in 79.1% of assessments. When seeking to assess plaster cast quality, the cast index and gap index should be calculated; if both indices agree, a decision on quality can be made. If the cast and gap indices disagree, the padding index can be calculated as a tiebreaker, and the decision based on the most frequent of the three results. Calculation of the three-point index and Canterbury index appears unnecessary. Copyright © 2016 Elsevier Ltd. All rights reserved.
Evaluation of cast creep occurring during simulated clubfoot correction
Cohen, Tamara L; Altiok, Haluk; Wang, Mei; McGrady, Linda M; Krzak, Joseph; Graf, Adam; Tarima, Sergey; Smith, Peter A; Harris, Gerald, F
2016-01-01
The Ponseti method is a widely accepted and highly successful conservative treatment of pediatric clubfoot involving weekly manipulations and cast applications. Qualitative assessments have indicated the potential success of the technique with cast materials other than standard plaster of Paris. However, guidelines for clubfoot correction based on the mechanical response of these materials have yet to be investigated. The current study sought to characterize and compare the ability of three standard cast materials to maintain the Ponseti corrected foot position by evaluating cast creep response. A dynamic cast testing device, built to model clubfoot correction, was wrapped in plaster-of-Paris, semi-rigid fiberglass, and rigid fiberglass. Three-dimensional motion responses to two joint stiffnesses were recorded. Rotational creep displacement and linearity of the limb-cast composite were analyzed. Minimal change in position over time was found for all materials. Among cast materials, the rotational creep displacement was significantly different (p < 0.0001). The most creep displacement occurred in the plaster-of-Paris (2.0 degrees), then the semi-rigid fiberglass (1.0 degrees), and then the rigid fiberglass (0.4 degrees). Torque magnitude did not affect creep displacement response. Analysis of normalized rotation showed quasi—linear viscoelastic behavior. This study provided a mechanical evaluation of cast material performance as used for clubfoot correction. Creep displacement dependence on cast material and insensitivity to torque were discovered. This information may provide a quantitative and mechanical basis for future innovations for clubfoot care. PMID:23636764
Vaidya, Sharad; Parkash, Hari; Bhargava, Akshay; Gupta, Sharad
2014-01-01
Abundant resources and techniques have been used for complete coverage crown fabrication. Conventional investing and casting procedures for phosphate-bonded investments require a 2- to 4-h procedure before completion. Accelerated casting techniques have been used, but may not result in castings with matching marginal accuracy. The study measured the marginal gap and determined the clinical acceptability of single cast copings invested in a phosphate-bonded investment with the use of conventional and accelerated methods. One hundred and twenty cast coping samples were fabricated using conventional and accelerated methods, with three finish lines: Chamfer, shoulder and shoulder with bevel. Sixty copings were prepared with each technique. Each coping was examined with a stereomicroscope at four predetermined sites and measurements of marginal gaps were documented for each. A master chart was prepared for all the data and was analyzed using Statistical Package for the Social Sciences version. Evidence of marginal gap was then evaluated by t-test. Analysis of variance and Post-hoc analysis were used to compare two groups as well as to make comparisons between three subgroups . Measurements recorded showed no statistically significant difference between conventional and accelerated groups. Among the three marginal designs studied, shoulder with bevel showed the best marginal fit with conventional as well as accelerated casting techniques. Accelerated casting technique could be a vital alternative to the time-consuming conventional casting technique. The marginal fit between the two casting techniques showed no statistical difference.
Jadhav, Vivek Dattatray; Motwani, Bhagwan K.; Shinde, Jitendra; Adhapure, Prasad
2017-01-01
Aims: The aim of this study was to evaluate the marginal fit and surface roughness of complete cast crowns made by a conventional and an accelerated casting technique. Settings and Design: This study was divided into three parts. In Part I, the marginal fit of full metal crowns made by both casting techniques in the vertical direction was checked, in Part II, the fit of sectional metal crowns in the horizontal direction made by both casting techniques was checked, and in Part III, the surface roughness of disc-shaped metal plate specimens made by both casting techniques was checked. Materials and Methods: A conventional technique was compared with an accelerated technique. In Part I of the study, the marginal fit of the full metal crowns as well as in Part II, the horizontal fit of sectional metal crowns made by both casting techniques was determined, and in Part III, the surface roughness of castings made with the same techniques was compared. Statistical Analysis Used: The results of the t-test and independent sample test do not indicate statistically significant differences in the marginal discrepancy detected between the two casting techniques. Results: For the marginal discrepancy and surface roughness, crowns fabricated with the accelerated technique were significantly different from those fabricated with the conventional technique. Conclusions: Accelerated casting technique showed quite satisfactory results, but the conventional technique was superior in terms of marginal fit and surface roughness. PMID:29042726
The Design of 3D-Printed Lattice-Reinforced Thickness-Varying Shell Molds for Castings.
Shangguan, Haolong; Kang, Jinwu; Yi, Jihao; Zhang, Xiaochuan; Wang, Xiang; Wang, Haibin; Huang, Tao
2018-03-30
3D printing technologies have been used gradually for the fabrication of sand molds and cores for castings, even though these molds and cores are dense structures. In this paper, a generation method for lattice-reinforced thickness-varying shell molds is proposed and presented. The first step is the discretization of the STL (Stereo Lithography) model of a casting into finite difference meshes. After this, a shell is formed by surrounding the casting with varying thickness, which is roughly proportional to the surface temperature distribution of the casting that is acquired by virtually cooling it in the environment. A regular lattice is subsequently constructed to support the shell. The outside surface of the shell and lattice in the cubic mesh format is then converted to STL format to serve as the external surface of the new shell mold. The internal surface of the new mold is the casting's surface with the normals of all of the triangles in STL format reversed. Experimental verification was performed on an Al alloy wheel hub casting. Its lattice-reinforced thickness-varying shell mold was generated by the proposed method and fabricated by the binder jetting 3D printing. The poured wheel hub casting was sound and of good surface smoothness. The cooling rate of the wheel hub casting was greatly increased due to the shell mold structure. This lattice-reinforced thickness-varying shell mold generation method is of great significance for mold design for castings to achieve cooling control.
A novel use of QR code stickers after orthopaedic cast application.
Gough, A T; Fieraru, G; Gaffney, Pav; Butler, M; Kincaid, R J; Middleton, R G
2017-07-01
INTRODUCTION We present a novel solution to ensure that information and contact details are always available to patients while in cast. An information sticker containing both telephone numbers and a Quick Response (QR) code is applied to the cast. When scanned with a smartphone, the QR code loads the plaster team's webpage. This contains information and videos about cast care, complications and enhancing recovery. METHODS A sticker was designed and applied to all synthetic casts fitted in our fracture clinic. On cast removal, patients completed a questionnaire about the sticker. A total of 101 patients were surveyed between November 2015 and February 2016. The questionnaire comprised ten binary choice questions. RESULTS The vast majority (97%) of patients had the sticker still on their cast when they returned to clinic for cast removal. Eighty-four per cent of all patients felt reassured by the presence of the QR code sticker. Nine per cent used the contact details on the cast to seek advice. Over half (56%) had a smartphone and a third (33%) of these scanned the QR code. Of those who scanned the code, 95% found the information useful. CONCLUSIONS This study indicates that use of a QR code reassures patients and is an effective tool in the proactive management of potential cast problems. The QR code sticker is now applied to all casts across our trust. In line with NHS England's Five Year Forward View calling for enhanced use of smartphone technology, our trust is continuing to expand its portfolio of patient information accessible via QR codes. Other branches of medicine may benefit from incorporating QR codes as portals to access such information.
Wang, Yu; Cao, Hai-yan; Xie, Ming-xing; He, Lin; Han, Wei; Hong, Liu; Peng, Yuan; Hu, Yun-fei; Song, Ben-cai; Wang, Jing; Wang, Bin; Deng, Cheng
2016-04-01
To investigate the application and effectiveness of vascular corrosion technique in preparing fetal cardiovascular cast models, 10 normal fetal heart specimens with other congenital disease (control group) and 18 specimens with severe congenital heart disease (case group) from induced abortions were enrolled in this study from March 2013 to June 2015 in our hospital. Cast models were prepared by injecting casting material into vascular lumen to demonstrate real geometries of fetal cardiovascular system. Casting effectiveness was analyzed in terms of local anatomic structures and different anatomical levels (including overall level, atrioventricular and great vascular system, left-sided and right-sided heart), as well as different trimesters of pregnancy. In our study, all specimens were successfully casted. Casting effectiveness analysis of local anatomic structures showed a mean score from 1.90±1.45 to 3.60±0.52, without significant differences between case and control groups in most local anatomic structures except left ventricle, which had a higher score in control group (P=0.027). Inter-group comparison of casting effectiveness in different anatomical levels showed no significant differences between the two groups. Intra-group comparison also revealed undifferentiated casting effectiveness between atrioventricular and great vascular system, or left-sided and right-sided heart in corresponding group. Third-trimester group had a significantly higher perfusion score in great vascular system than second-trimester group (P=0.046), while the other anatomical levels displayed no such difference. Vascular corrosion technique can be successfully used in fabrication of fetal cardiovascular cast model. It is also a reliable method to demonstrate three-dimensional anatomy of severe congenital heart disease and normal heart in fetus.
Effect of pressure difference on the quality of titanium casting.
Watanabe, I; Watkins, J H; Nakajima, H; Atsuta, M; Okabe, T
1997-03-01
In casting titanium using a two-compartment casting machine, Herø et al. (1993) reported that the pressure difference between the melting chamber and the mold chamber affected the soundness of the castings. This study tested the hypothesis that differences in pressure produce castings with various amounts of porosity and different mechanical properties values. Plastic dumbbell-shaped patterns were invested with an alumina-based, phosphate-bonded investment material. Both chambers of the casting machine were evacuated to 6 x 10(-2) torr; the argon pressure difference was then adjusted to either 50, 150, 300, or 450 torr. The porosity of the cast specimens was determined by x-ray radiography and quantitative image analysis. Tensile strength and elongation were measured by means of a universal testing machine at a strain rate of 1.7 x 10(-4)/s. The fractured surfaces were examined by SEM. Changes in Vickers hardness with depth from the cast surface were measured on polished cross-sections of the specimens. Raising the argon pressure difference to 300 and 450 torr caused a significant increase in internal porosity and a resultant decrease in the engineering tensile strength and elongation. The highest tensile strength (approximately 540 MPa), elongation (approximately 10%), bulk hardness (HV50g 209), and lowest porosity level (approximately 0.8%) occurred in the specimens cast at 150 torr. Turbulence of the metal during casting was thought to be responsible for the increase in porosity levels with the increase in argon pressure difference. By choosing an argon pressure difference (around 150 torr) suitable for this geometry, we could produce castings which have adequate mechanical properties and low porosity levels.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nick Cannell; Dr. Mark Samonds; Adi Sholapurwalla
The investment casting process is an expendable mold process where wax patterns of the part and rigging are molded, assembled, shelled and melted to produce a ceramic mold matching the shape of the component to be cast. Investment casting is an important manufacturing method for critical parts because of the ability to maintain dimensional shape and tolerances. However, these tolerances can be easily exceeded if the molding components do not maintain their individual shapes well. In the investment casting process there are several opportunities for the final casting shape to not maintain the intended size and shape, such as shrinkagemore » of the wax in the injection tool, the modification of the shape during shell heating, and with the thermal shrink and distortion in the casting process. Studies have been completed to look at the casting and shell distortions through the process in earlier phases of this project. Dr. Adrian Sabau at Oak Ridge National Labs performed characterizations and validations of 17-4 PH stainless steel in primarily fused silica shell systems with good agreement between analysis results and experimental data. Further tasks provided material property measurements of wax and methodology for employing a viscoelastic definition of wax materials into software. The final set of tasks involved the implementation of the findings into the commercial casting analysis software ProCAST, owned and maintained by ESI Group. This included: o the transfer of the wax material property data from its raw form into separate temperature-dependent thermophysical and mechanical property datasets o adding this wax material property data into an easily viewable and modifiable user interface within the pre-processing application of the ProCAST suite, namely PreCAST o and validating the data and viscoelastic wax model with respect to experimental results« less
Spall behavior of cast iron with varying microstructures
NASA Astrophysics Data System (ADS)
Plume, Gifford; Rousseau, Carl-Ernst
2014-07-01
The spall strength of cast iron with varying microstructures has been investigated using plate impact at moderate speed. Stress history measurements were made with manganin stress gauges embedded between the back face of the specimen and a low impedance polycarbonate backing. Five separate cast irons were tested. Four of these consisted of gray cast iron with graphite in flake form, with three classified as Type VII A2 and the fourth containing a bimodal distribution of Types VII A4 and VII D8. The fifth casting consisted of ductile cast iron with graphite in nodular form, classified as Type I, size class 5. The spall strength for the Type VII A2 gray cast irons varied between 40 and 370 MPa, and that of the additional gray cast iron, between 410 and 490 MPa. The spall strength of the ductile cast iron fell within the range of 0.94-1.2 GPa. It is shown that the spall strength is linked to the damage level at the spall plane, where an increased level of tensile stress is required to generate higher levels of damage. Post mortem analysis was performed on the recovered samples, revealing the graphite phase to be the primary factor governing the spall fracture of cast irons, where crack nucleation is directly correlated to the debonding of graphite from the metal matrix. The average length of graphite found within a casting is linked to the material's strength, where strength increases as a function of decreasing length. The morphology and mean free path of graphite precipitates further govern the subsequent coalescence of initiated cracks to form a complete fracture plane. In cases where graphite spacing is large, increased energy level is required to complete the fracture process. A secondary factor governing the spall fracture of cast irons has also been linked to the microstructure of the metal matrix, with pearlite yielding higher spall strengths than free ferrite.
Comparative study of two commercially pure titanium casting methods
RODRIGUES, Renata Cristina Silveira; FARIA, Adriana Claudia Lapria; ORSI, Iara Augusta; de MATTOS, Maria da Gloria Chiarello; MACEDO, Ana Paula; RIBEIRO, Ricardo Faria
2010-01-01
The interest in using titanium to fabricate removable partial denture (RPD) frameworks has increased, but there are few studies evaluating the effects of casting methods on clasp behavior. Objective This study compared the occurrence of porosities and the retentive force of commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) removable partial denture circumferential clasps cast by induction/centrifugation and plasma/vacuum-pressure. Material and Methods 72 frameworks were cast from CP Ti (n=36) and Co-Cr alloy (n=36; control group). For each material, 18 frameworks were casted by electromagnetic induction and injected by centrifugation, whereas the other 18 were casted by plasma and injected by vacuum-pressure. For each casting method, three subgroups (n=6) were formed: 0.25 mm, 0.50 mm, and 0.75 mm undercuts. The specimens were radiographed and subjected to an insertion/removal test simulating 5 years of framework use. Data were analyzed by ANOVA and Tukey's to compare materials and cast methods (α=0.05). Results Three of 18 specimens of the induction/centrifugation group and 9 of 18 specimens of plasma/vacuum-pressure cast presented porosities, but only 1 and 7 specimens, respectively, were rejected for simulation test. For Co-Cr alloy, no defects were found. Comparing the casting methods, statistically significant differences (p<0.05) were observed only for the Co-Cr alloy with 0.25 mm and 0.50 mm undercuts. Significant differences were found for the 0.25 mm and 0.75 mm undercuts dependent on the material used. For the 0.50 mm undercut, significant differences were found when the materials were induction casted. Conclusion Although both casting methods produced satisfactory CP Ti RPD frameworks, the occurrence of porosities was greater in the plasma/vacuum-pressure than in the induction/centrifugation method, the latter resulting in higher clasp rigidity, generating higher retention force values. PMID:21085805
Effect of surface contamination on adhesive bonding of cast pure titanium and Ti-6Al-4V alloy.
Watanabe, I; Watanabe, E; Yoshida, K; Okabe, T
1999-03-01
There is little information regarding bond strengths of resin cements to cast titanium surfaces contaminated by investment material. This study examined the effect of surface contamination on the shear bond strength of resin cements to cast titanium and Ti-6Al-4V alloy. Two types of disks were cast from commercially pure titanium (CP-Ti) and Ti-6Al-4V alloy ingots using an argon-arc pressure casting unit and a phosphate-bonded Al2 O3 /LiAlSiO6 investment. After casting, disks were subjected to 3 surface treatments: (1) cast surface sandblasted (50 microm-sized Al2 O3 ) for 30 seconds; (2) metal surface sanded with silicon-carbide paper (600 grit) after grinding the contaminated cast surface (approximately 200 microm in thickness); and (3) metal surface sandblasted for 30 seconds after treatment 2. Surface structures were examined after each treatment with SEM and optical microscopy. Each type of disk was then bonded with 2 types of luting materials. Bonded specimens were subjected to thermocycling for up to 50,000 cycles, and shear bond strengths were determined after 0 (baseline) and 50,000 thermocycles. Results were statistically analyzed with 3-way ANOVA (P <.05). Microscopic observation of cast CP-Ti and Ti-6Al-4V exhibited noticeable structures on the cast surfaces apparently contaminated with investment material. However, there were no statistical differences (P >.05) in the bond strengths of both cements between contaminated (treatment 1) and uncontaminated surfaces (treatment 3) for both metals at baseline and after 50,000 thermocycles. The bond strength of specimens sanded with silicon-carbide paper (treatment 2) deteriorated dramatically after 50,000 thermocycles. Contamination of the cast metal surfaces by elements of the investment during casting did not affect bond strengths of the luting materials to CP-Ti and Ti-6Al-4V.
Matin, Ivan; Hadzistevic, Miodrag; Vukelic, Djordje; Potran, Michal; Brajlih, Tomaz
2017-07-01
Nowadays, the integrated CAD/CAE systems are favored solutions for the design of simulation models for casting metal substructures of metal-ceramic crowns. The worldwide authors have used different approaches to solve the problems using an expert system. Despite substantial research progress in the design of experts systems for the simulation model design and manufacturing have insufficiently considered the specifics of casting in dentistry, especially the need for further CAD, RE, CAE for the estimation of casting parameters and the control of the casting machine. The novel expert system performs the following: CAD modeling of the simulation model for casting, fast modeling of gate design, CAD eligibility and cast ability check of the model, estimation and running of the program code for the casting machine, as well as manufacturing time reduction of the metal substructure. The authors propose an integration method using common data model approach, blackboard architecture, rule-based reasoning and iterative redesign method. Arithmetic mean roughness values was determinated with constant Gauss low-pass filter (cut-off length of 2.5mm) according to ISO 4287 using Mahr MARSURF PS1. Dimensional deviation between the designed model and manufactured cast was determined using the coordinate measuring machine Zeiss Contura G2 and GOM Inspect software. The ES allows for obtaining the castings derived roughness grade number N7. The dimensional deviation between the simulation model of the metal substructure and the manufactured cast is 0.018mm. The arithmetic mean roughness values measured on the casting substructure are from 1.935µm to 2.778µm. The realized developed expert system with the integrated database is fully applicable for the observed hardware and software. Values of the arithmetic mean roughness and dimensional deviation indicate that casting substructures are surface quality, which is more than enough and useful for direct porcelain veneering. The manufacture of the substructure shows that the proposed ES allows the improvement of the design process while reducing the manufacturing time. Copyright © 2017 Elsevier B.V. All rights reserved.
Cao, Jun; Zhang, Xue-Jun; Sun, Ning; Sun, Lin; Guo, Dong; Qi, Xin-Yu; Bai, Yun-Song; Sun, Bao-Sheng
2017-04-04
The therapeutic efficacy of serial casting on idiopathic scoliosis has been gradually documented. However, literatures on serial casting for congenital scoliosis (CS) remain extremely rare. This paper aimed to compare the treatment outcomes of serial casting between CS and non-CS patients to comprehensively evaluate the therapeutic characteristics of serial casting on CS patients. A total of 23 early-onset scoliosis cases were included and divided into congenital scoliosis (CS, n = 8) and non-congenital group (non-CS, n = 15). Therapeutic outcomes including the major curve Cobb angle, thoracic kyphosis angle, lumbar lodosis angle, and thoracic spine growing rate were compared between groups at precast, after the first cast, and at the latest follow-up, respectively. All patients received the first cast at the age of 3.25 ± 1.20 years and 5.70 ± 1.18 times of cast corrections. The average casting time was 17.17 ± 3.38 months, and the mean follow-up time was 23.91 ± 12.28 months. Both CS and non-CS groups had significant decrease in Cobb angle after the first cast and at the latest follow-up (all P < 0.05). Cobb angle was significantly lower in non-CS group than in CS group at both time points (all P < 0.01). The correction rate of Cobb angle was significantly higher in non-CS group than in CS group (around 50 vs. 20%, both P < 0.01). The mean thoracic growth rate was significantly lower in CS group than in non-CS group (0.72 ± 0.20 vs. 1.42 ± 0.22 cm/year, P < 0.001). At the latest follow-up, there are 2 cases receiving growing rod surgery, 8 cases wearing a brace, and 13 cases continuing serial casting. Although the therapeutic efficacy of casting on CS patients is not as good as that on non-CS patients, casting is still an efficient treatment option for CS patients to delay the need for initial surgery.
Krahenbuhl, Jason T; Cho, Seok-Hwan; Irelan, Jon; Bansal, Naveen K
2016-08-01
Little peer-reviewed information is available regarding the accuracy and precision of the occlusal contact reproduction of digitally mounted stereolithographic casts. The purpose of this in vitro study was to evaluate the accuracy and precision of occlusal contacts among stereolithographic casts mounted by digital occlusal registrations. Four complete anatomic dentoforms were arbitrarily mounted on a semi-adjustable articulator in maximal intercuspal position and served as the 4 different simulated patients (SP). A total of 60 digital impressions and digital interocclusal registrations were made with a digital intraoral scanner to fabricate 15 sets of mounted stereolithographic (SLA) definitive casts for each dentoform. After receiving a total of 60 SLA casts, polyvinyl siloxane (PVS) interocclusal records were made for each set. The occlusal contacts for each set of SLA casts were measured by recording the amount of light transmitted through the interocclusal records. To evaluate the accuracy between the SP and their respective SLA casts, the areas of actual contact (AC) and near contact (NC) were calculated. For precision analysis, the coefficient of variation (CoV) was used. The data was analyzed with t tests for accuracy and the McKay and Vangel test for precision (α=.05). The accuracy analysis showed a statistically significant difference between the SP and the SLA cast of each dentoform (P<.05). For the AC in all dentoforms, a significant increase was found in the areas of actual contact of SLA casts compared with the contacts present in the SP (P<.05). Conversely, for the NC in all dentoforms, a significant decrease was found in the occlusal contact areas of the SLA casts compared with the contacts in the SP (P<.05). The precision analysis demonstrated the different CoV values between AC (5.8 to 8.8%) and NC (21.4 to 44.6%) of digitally mounted SLA casts, indicating that the overall precision of the SLA cast was low. For the accuracy evaluation, statistically significant differences were found between the occlusal contacts of all digitally mounted SLA casts groups, with an increase in AC values and a decrease in NC values. For the precision assessment, the CoV values of the AC and NC showed the digitally articulated cast's inability to reproduce the uniform occlusal contacts. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Ayzenberg, Mark; Narvaez, Michael; Raphael, James
2018-01-01
Casting is routinely used for acute and post-operative immobilization and remains a cornerstone in the non-operative management of fractures and deformities. The application of a properly fitted and wellmolded cast, especially for a trainee, can be challenging. We present a simple method of prolonging cure time of fiberglass cast — placing ice in the dip water. Eight-ply, fiveinch fiberglass cast was circumferentially applied to an aluminum-wrapped cardboard cylinder. An electronic, 2-channel temperature sensor (TR-71wf Temp Logger, T&D Corporation, Matsumoto, Japan), accurate to 0.1ºC and accurate to ±0.3ºC, was placed between the fourth and fifth layers of fiberglass. Thirty total casts were tested using 9±1ºC (cold), 22±1ºC (ambient), and 36±1ºC (warm) dip water. Room temperature was maintained at 24±1ºC. Cast temperatures were measured during the exothermic reaction generated by the cast curing. Peak temperatures and cure times were recorded. Cure time was defined as the point of downward deflection on the timetemperature curve immediately after peak. Cure and peak temperatures were compared among groups using analysis of variance. Mean cure time was 3.5±0.1 minutes for warm water, 5.0±0.4 minutes for ambient water and 7.0±0.5 minutes for cold water. Peak temperature, measured between layers 4 and 5 of the cast material, was 36.6±0.8ºC for warm water, 31.1±1.4ºC for ambient water and 25.2±0.5ºC for cold water. Cold afforded, on average, an additional 2 minutes (40% increase) in cure time compared to ambient water and an additional 3.5 minutes (100% increase) compared to warm water. Cure time differences were significant (P<0.001) for all groups, as were peak temperature differences (P<0.001). Temperatures concerning for development of burns were never reached. Utilizing iced dip water when casting is a simple and effective method to prolong the time available for cast application. Orthopedic residents and trainees may find this useful in learning to fabricate a high quality cast. For the experienced orthopedic surgeon, this method eliminates the need to bridge longlimb casts and facilitates the application of complex casts. PMID:29770174
Hruska, A R; Borelli, P
1991-10-01
Procedures for casting, laboratory soldering, and intraoral welding of titanium for dental restorations are described and illustrated. Pure titanium and titanium 6A1-4Va alloy castings may be used for virtually any prosthodontic rehabilitation as well as for implants, with the proper equipment and technique.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-07
... DEPARTMENT OF COMMERCE International Trade Administration [A-570-875] Non-Malleable Cast Iron Pipe...-malleable cast iron pipe fittings from the People's Republic of China (``PRC''). See Initiation of...-malleable cast iron pipe fittings from the PRC within the time limits mandated by section 751(a)(3)(A) of...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-08
...] Certain Iron Construction Castings From Brazil, Canada, and the People's Republic of China: Final Results... construction castings from Brazil, Canada, and the People's Republic of China (PRC), pursuant to section 751(c... antidumping duty orders\\1\\ on certain iron construction castings from Brazil, Canada, and the PRC pursuant to...
Khavandi, Kaivan; Brownrigg, Jack; Hankir, Mohammed; Sood, Harpreet; Younis, Naveed; Worth, Joy; Greenstein, Adam; Soran, Handrean; Wierzbicki, Anthony; Goldsmith, David J
2014-01-01
In recent decades we have seen a surge in the incidence of diabetes in industrialized nations; a threat which has now extended to the developing world. Type 2 diabetes is associated with significant microvascular and macrovascular disease, with considerable impact on morbidity and mortality. Recent evidence has cast uncertainty on the benefits of very tight glycaemic goals in these individuals. The natural history of disease follows an insidious course from disordered glucose metabolism in a pre-diabetic state, often with metabolic syndrome and obesity, before proceeding to diabetes mellitus. In the research setting, lifestyle, pharmacological and surgical intervention targeted against obesity and glycaemia has shown that metabolic disturbances can be halted and indeed regressed if introduced at an early stage of disease. In addition to traditional anti-diabetic medications such as the glinides, sulphonylureas and the glitazones, novel therapies manipulating the endocannabinoid system, neurotransmitters, intestinal absorption and gut hormones have shown dual benefit in weight loss and glycaemic control normalisation. Whilst these treatments will not and should not replace lifestyle change, they will act as invaluable adjuncts for weight loss and aid in normalising the metabolic profile of individuals at risk of diabetes. Utilizing novel therapies to prevent diabetes should be the focus of future research, with the aim of preventing the challenging microvascular and macrovascular complications, and ultimately cardiovascular death.
NASA Astrophysics Data System (ADS)
Sun, Zhizhong; Niu, Xiaoping; Hu, Henry
In this work, a different wall-thickness 5-step (with thicknesses as 3, 5, 8, 12, 20 mm) casting mold was designed, and squeeze casting of magnesium alloy AM60 was performed in a hydraulic press. The casting-die interfacial heat transfer coefficients (IHTC) in 5-step casting were determined based on experimental thermal histories data throughout the die and inside the casting which were recorded by fine type-K thermocouples. With measured temperatures, heat flux and IHTC were evaluated using the polynomial curve fitting method. The results show that the wall thickness affects IHTC peak values significantly. The IHTC value for the thick step is higher than that for the thin steps.
Method and apparatus for planar drag strip casting
Powell, John C.; Campbell, Steven L.
1991-01-01
The present invention is directed to an improved process and apparatus for strip casting. The combination of a planar flow casting nozzle positioned back from the top dead center position with an attached nozzle extension, provides an increased level of casting control and quality. The nozzle extension provides a means of containing the molten pool above the rotating substrate to increase the control of molten metal at the edges of the strip and increase the range of coating thicknesses which may be produced. The level of molten metal in the containment means is regulated to be above the level of melt supplying the casting nozzle which produces a condition of planar drag flow with the casting substrate prior to solidification.
Method and apparatus for planar drag strip casting
Powell, J.C.; Campbell, S.L.
1991-11-12
The present invention is directed to an improved process and apparatus for strip casting. The combination of a planar flow casting nozzle positioned back from the top dead center position with an attached nozzle extension, provides an increased level of casting control and quality. The nozzle extension provides a means of containing the molten pool above the rotating substrate to increase the control of molten metal at the edges of the strip and increase the range of coating thicknesses which may be produced. The level of molten metal in the containment means is regulated to be above the level of melt supplying the casting nozzle which produces a condition of planar drag flow with the casting substrate prior to solidification. 5 figures.
1998-01-01
Don Sirois, an Auburn University research associate, and Bruce Strom, a mechanical engineering Co-Op Student, are evaluating the dimensional characteristics of an aluminum automobile engine casting. More accurate metal casting processes may reduce the weight of some cast metal products used in automobiles, such as engines. Research in low gravity has taken an important first step toward making metal products used in homes, automobiles, and aircraft less expensive, safer, and more durable. Auburn University and industry are partnering with NASA to develop one of the first accurate computer model predictions of molten metals and molding materials used in a manufacturing process called casting. Ford Motor Company's casting plant in Cleveland, Ohio is using NASA-sponsored computer modeling information to improve the casting process of automobile and light-truck engine blocks.
GPU-based multi-volume ray casting within VTK for medical applications.
Bozorgi, Mohammadmehdi; Lindseth, Frank
2015-03-01
Multi-volume visualization is important for displaying relevant information in multimodal or multitemporal medical imaging studies. The main objective with the current study was to develop an efficient GPU-based multi-volume ray caster (MVRC) and validate the proposed visualization system in the context of image-guided surgical navigation. Ray casting can produce high-quality 2D images from 3D volume data but the method is computationally demanding, especially when multiple volumes are involved, so a parallel GPU version has been implemented. In the proposed MVRC, imaginary rays are sent through the volumes (one ray for each pixel in the view), and at equal and short intervals along the rays, samples are collected from each volume. Samples from all the volumes are composited using front to back α-blending. Since all the rays can be processed simultaneously, the MVRC was implemented in parallel on the GPU to achieve acceptable interactive frame rates. The method is fully integrated within the visualization toolkit (VTK) pipeline with the ability to apply different operations (e.g., transformations, clipping, and cropping) on each volume separately. The implemented method is cross-platform (Windows, Linux and Mac OSX) and runs on different graphics card (NVidia and AMD). The speed of the MVRC was tested with one to five volumes of varying sizes: 128(3), 256(3), and 512(3). A Tesla C2070 GPU was used, and the output image size was 600 × 600 pixels. The original VTK single-volume ray caster and the MVRC were compared when rendering only one volume. The multi-volume rendering system achieved an interactive frame rate (> 15 fps) when rendering five small volumes (128 (3) voxels), four medium-sized volumes (256(3) voxels), and two large volumes (512(3) voxels). When rendering single volumes, the frame rate of the MVRC was comparable to the original VTK ray caster for small and medium-sized datasets but was approximately 3 frames per second slower for large datasets. The MVRC was successfully integrated in an existing surgical navigation system and was shown to be clinically useful during an ultrasound-guided neurosurgical tumor resection. A GPU-based MVRC for VTK is a useful tool in medical visualization. The proposed multi-volume GPU-based ray caster for VTK provided high-quality images at reasonable frame rates. The MVRC was effective when used in a neurosurgical navigation application.
Tomonaga, Masaki; Imura, Tomoko
2010-07-08
Humans readily perceive whole shapes as intact when some portions of these shapes are occluded by another object. This type of amodal completion has also been widely reported among nonhuman animals and is related to pictorial depth perception. However, the effect of a cast shadow, a critical pictorial-depth cue for amodal completion has been investigated only rarely from the comparative-cognitive perspective. In the present study, we examined this effect in chimpanzees and humans. Chimpanzees were slower in responding to a Pacman target with an occluding square than to the control condition, suggesting that participants perceptually completed the whole circle. When a cast shadow was added to the square, amodal completion occurred in both species. On the other hand, however, critical differences between the species emerged when the cast shadow was added to the Pacman figure, implying that Pacman was in the sky casting a shadow on the square. The cast shadow prevented, to a significant extent, compulsory amodal completion in humans, but had no effect on chimpanzees. These results suggest that cast shadows played a critical role in enabling humans to infer the spatial relationship between Pacman and the square. For chimpanzees, however, a cast shadow may be perceived as another "object". A limited role for cast shadows in the perception of pictorial depth has also been reported with respect to human cognitive development. Further studies on nonhuman primates using a comparative-developmental perspective will clarify the evolutionary origin of the role of cast shadows in visual perception.
Ashma, R; Kashyap, V K
2003-01-01
The formation of caste groups among the Hindu community and the practice of endogamy exert a great impact on the genetic structure and diversity of the Indian population. Allele frequency data of 15 microsatellite loci clearly portray the genetic diversity and relatedness among four socio-culturally advanced caste groups: Brahmin, Bhumihar, Rajput and Kayasth of Caucasoid ethnicity of Bihar. The study seeks to understand the impact of the man-made caste system on the genetic profile of the four major caste groups of Bihar. Computation of average heterozygosity, most frequent allele, allele diversity and coefficient of gene differentiation (Gst), along with genetic distance (DA)and principal coordinate analysis were performed to assess intra-population and inter-population diversity. The average Gst value for all the loci was 0.012 +/- 0.0033, and the level of average heterozygosity was approximately 75.5%, indicating genetic similarity and intra-population diversity. Genetic distance (DA) values and the phylogenetic tree along with other higher caste groups of India indicate the relative distance between them. The present study clearly depicts the genetic profile of these caste groups, their inherent closeness in the past, and the impact of the imposed caste system that later restricted the gene flow. The study highlights the status of Bhumihar and Kayasth in the Hindu caste system. The former was found clustering with the Brahmin group (as expected, since Bhumihar is known to be a subclass of Brahmin), whereas the distance between the Brahmin and Kayasth caste groups was found to be large. North-eastern Indian Mongoloids form a separate cluster.
NASA Astrophysics Data System (ADS)
Bandanadjaja, Beny; Purwadi, Wiwik; Idamayanti, Dewi; Lilansa, Noval; Hanaldi, Kus; Nurzaenal, Friya Kurnia
2018-05-01
Hard metal castings are widely used in the coal mill pulverizer as construction material for coal crushers. During its operation crushers and mills experience degradation caused by abrasion load. This research dealed with the surface overlaying of similiar material on the surface of white cast iron by mean of gravity casting. The die blank casting was preheated prior to the casting process of outer layer made of Ni-Hard white cast iron to guarantee bonding processes and avoid any crack. The preheating temperature of die blankin ther range of 500C up to 850C was set up to reach the interface temperature in the range of 887°C -1198°C and the flushing time was varied between 10-20 seconds. Studies carried on the microstructure of sample material revealed a formation of metallurgical bonding at the preheating temperature above 625 °C by pouring temperature ranging from 1438 °C to 1468 °C. Metallographical and chemical composition by mean of EDS examination were performed to observed the resut. This research concludes that the casting of Ni-Hard 1 overlay by applying gravity casting method can be done by preheating the surface of casting to 625 °C, interface temperature of 1150 °C, flushing time of 7 seconds and pouring temperature of 1430 °C. Excellent metallurgical bonding at the contact area between dieblank and overlay material has been achieved in which there is no parting line at the interface area to be observed.
Casting made simple using modified sprue design: an in vitro study.
Baskaran, B Eswaran; Geetha Prabhu, K R; Prabhu, R; Krishna, G Phani; Eswaran, M A; Gajapathi, B
2014-01-01
Success in dental casting restorations for fixed partial dentures (FPDs) depends on the castability. Castability is described as the ability of an alloy to faithfully reproduce sharp detail and fine margins of a wax pattern. The goal of a prosthodontist is to provide the patient with restorations that fit precisely. Regardless of the alloy used for casting, the casting technique should yield a casted alloy, which should possess sufficient mass, surface hardness and minimal porosity after casting. Twenty patterns for casting were made from three-dimensional printed resin pattern simulating a 3 unit FPD and casted using modified sprue technique. Later test samples were cemented sequentially on stainless steel model using pressure indicating paste and evaluated for vertical marginal gap in eight predetermined reference areas. Marginal gap were measured in microns using Video Measuring System (VMS2010F-CIP Corporation, Korea). A portion of the axial wall of the cast abutments depicting premolar and molar were sectioned and embedded in acrylic resin and tested for micro hardness using Reichert Polyvar 2 Met Microhardness tester (Reichert, Austria) and porosity using Quantimet Image Analyzer (Quantimet Corporation London, England). The results obtained for marginal gap, micro hardness, and porosity of all test samples were tabulated, descriptive statistics were calculated and the values were found to be within the clinically acceptable range. The new sprue technique can be an alternative and convenient method for casting which would minimize metal wasting and less time consuming. However, further studies with same technique on various parameters are to be conducted for its broad acceptance.
Sixty Years of Casting Research
NASA Astrophysics Data System (ADS)
Campbell, John
2015-11-01
The 60 years of solidification research since the publication of Chalmer's constitutional undercooling in 1953 has been a dramatic advance of understanding which has and continues to be an inspiration. In contrast, 60 years of casting research has seen mixed fortunes. One of its success stories relates to improvements in inoculation of gray irons, and another to the discovery of spheroidal graphite iron, although both of these can be classified as metallurgical rather than casting advances. It is suggested that true casting advances have dated from the author's lab in 1992 when a critical surface turbulence condition was defined for the first time. These last 20 years have seen the surface entrainment issues of castings developed to a sufficient sophistication to revolutionize the performance of light alloy and steel foundries. However, there is still a long way to go, with large sections of the steel and Ni-base casting industries still in denial that casting defects are important or even exist. The result has been that special ingots are still cast poorly, and shaped casting operations have suffered massive losses. For secondary melted and cast materials, electro-slag remelting has the potential to be much superior to expensive vacuum arc remelting, which has cost our aerospace and defense industries dearly over the years. This failure to address and upgrade our processing of liquid metals is a serious concern, since the principle entrainment defect, the bifilm, is seen as the principle initiator of cracks in metals; in general, bifilms are the Griffith cracks that initiate failures by cracking. A new generation of crack resistant metals and engineering structures can now be envisaged.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weiss, David; Purgert, Robert; Rhudy, Richard
1999-04-21
Some highlights are: (1) Material development, process development, and part validation are occurring simultaneously on a fast track schedule. (2) Prior project activity has resulted in a program emphasis on three components--manifolds, mounting brackets, and motor mounts; and three casting techniques--squeeze casting, pressure die casting, and sand casting. (3) With the project focus, it appears possible to offer manifolds and mounting brackets for automotive qualification testing on a schedule in line with the PNGV Year 2004 goal. (4) Through an iterative process of fly ash treatment, MMC ingot preparation, foundry process refinement, and parts production, both foundries (Eck Industries andmore » Thompson Aluminum Casting Company) are addressing the pre-competitive issues of: (a) Optimum castability with fly ash shapes and sizes; (b) Best mechanical properties derived from fly ash shapes and sizes; (c) Effective fly ash classification processes; (d) Mechanical properties resulting from various casting processes and fly ash formulations. Eck and TAC continued experiments with batch ingot provided by both Eck and the University of Wisconsin at Milwaukee. Castings were run that contained varying amounts of fly ash and different size fractions. Components were cast using cenosphere material to ascertain the effects of squeeze casting and to determine whether the pressure would break the cenospheres. Test parts are currently being machined into substandard test bars for mechanical testing. Also, the affect of heat treatments on ashalloy are being studied through comparison to two lots, one heat treated and one in the ''as cast'' condition.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weiss, David; Purgert, Robert; Rhudy, Richard
2000-04-21
The highlights of this report are: (1) fly ash classified by less than 100 microns in size was mixed into a 300 lb melt of alloy 535 without the need of a magnesium additive; (2) a vibratory feeder fitted with a sieve was used as the means to minimize particle clustering while introducing fly ash into the aluminum alloy 535 melt; and (3) the industrial-size field test was successful in that sand mold castings and permanent mold castings of tensile bars, K mold bars, and ingots were made from aluminum alloy 535-fly ash mix. Use of aluminum alloy 535 containingmore » 7% magnesium precluded the need to introduce additional magnesium into the melt. The third round of sand mold castings as well as permanent mold castings produced components and ingots of alloy 535 instead of alloy 356. The ingots will be remelted and cast into parts to assess the improvement of flyash distribution which occurs through reheating and the solidification wetting process. Microstructure analysis continues on sand and permanent mold castings to study particle distribution in the components. A prototype sand cast intake manifold casting was found to be pressure tight which is a major performance requirement for this part. Another heat of pressure die cast brackets of A380-classified fly ash will be made to examine their strength and fly ash distribution. Ingots of A356-fly ash have been made at Eck for remelting at Thompson Aluminum for squeeze casting into motor mounts.« less
Forni, Cristiana; Zoli, Marina; Loro, Loretta; Tremosini, Morena; Mini, Sandra; Pirini, Valter; Turrini, Roberta; Durante, Stefano; Nicolini, Annamaria; Riccioni, Francesca; Girolami, Roberto
2009-01-01
Pressure sores, especially at the heel, are a side effect of the cast. To assess the incidence of late skin complications (heel pressure sores) of a cast and determine risk factors. All consecutive patients treated with a leg cast over a 16 months observation time were recruited. Risk factors were identified by the nurse that placed the cast and skin lesions classified with the NPUAP scale when the cast was removed. In the 216 enrolled patients 17.6% (38) developed a pressure sore: 16/124 in orthopedic wards; 22/92 in oncology wards. The multivariate analysis identified the following risk factors: administration of cytotoxic drugs (p = 0.033; OR = 2.61; having a cancer did not increase the risk); skin redness before cast application (p = 0.001; OR = 4.44) and having reported symptoms after the application (p = 0.000; OR = 7.86). Pressure sores were mainly stage 1 and only 6/216 (2.4%) > or = stage II. The type of plaster cast, the material, the number of days it was worn and having had a surgery are not significant risk factors. Pressure sores related to leg plaster casts are a frequent complication in at risk sub-groups. The acknowledgement and identification of specific risk factors may allow to identify and evaluate preventive interventions to improve the care of these patients.
Accuracy of impressions with different impression materials in angulated implants.
Reddy, S; Prasad, K; Vakil, H; Jain, A; Chowdhary, R
2013-01-01
To evaluate the dimensional accuracy of the resultant (duplicative) casts made from two different impression materials (polyvinyl siloxane and polyether) in parallel and angulated implants. Three definitive master casts (control groups) were fabricated in dental stone with three implants, placed at equi-distance. In first group (control), all three implants were placed parallel to each other and perpendicular to the plane of the cast. In the second and third group (control), all three implants were placed at 10° and 15 o angulation respectively to the long axis of the cast, tilting towards the centre. Impressions were made with polyvinyl siloxane and polyether impression materials in a special tray, using a open tray impression technique from the master casts. These impressions were poured to obtain test casts. Three reference distances were evaluated on each test cast by using a profile projector and compared with control groups to determine the effect of combined interaction of implant angulation and impression materials on the accuracy of implant resultant cast. Statistical analysis revealed no significant difference in dimensional accuracy of the resultant casts made from two different impression materials (polyvinyl siloxane and polyether) by closed tray impression technique in parallel and angulated implants. On the basis of the results of this study, the use of both the impression materials i.e., polyether and polyvinyl siloxane impression is recommended for impression making in parallel as well as angulated implants.
Compound cast product and method for producing a compound cast product
Meyer, Thomas N.; Viswanathan, Srinath
2002-09-17
A compound cast product is formed in a casting mold (14) having a mold cavity (16) sized and shaped to form the cast product. A plurality of injectors (24) is supported from a bottom side (26) of the casting mold (14). The injectors (24) are in fluid communication with the mold cavity (16) through the bottom side (26) of the casting mold (14). A molten material holder furnace (12) is located beneath the casting mold (14). The holder furnace (12) defines molten material receiving chambers (36) configured to separately contain supplies of two different molten materials (37, 38). The holder furnace (12) is positioned such that the injectors (24) extend downward into the receiving chamber (36). The receiving chamber (36) is separated into at least two different flow circuits (51, 52). A first molten material (37) is received in a first flow circuit (51), and a second molten material (38) is received into a second flow circuit (52). The first and second molten materials (37, 38) are injected into the mold cavity (16) by the injectors (24) acting against the force of gravity. The injectors (24) are positioned such that the first and second molten materials (37, 38) are injected into different areas of the mold cavity (16). The molten materials (37, 38) are allowed to solidify and the resulting compound cast product is removed from the mold cavity (16).
Code of Federal Regulations, 2011 CFR
2011-07-01
... standards for open molding and centrifugal casting operations at new and existing sources? 63.5810 Section... § 63.5810 What are my options for meeting the standards for open molding and centrifugal casting... (d) of this section to meet the standards for open molding or centrifugal casting operations in Table...
Code of Federal Regulations, 2010 CFR
2010-07-01
... standards for open molding and centrifugal casting operations at new and existing sources? 63.5810 Section... § 63.5810 What are my options for meeting the standards for open molding and centrifugal casting... (d) of this section to meet the standards for open molding or centrifugal casting operations in Table...
ERIC Educational Resources Information Center
Kapoor, Dip
2007-01-01
Despite the constitutional ban on the practice of untouchability and caste-based discrimination, this article elaborates on a gendered-caste-based discriminatory reality in rural India, the difficulties of enforcing legal remedies, and on related human rights praxis to address gendered-caste atrocities by drawing on the experiences of a Canadian…
2016-12-10
will be 2 x failure (critical) depth. G. INSPECTION REQUIREMENTS Either the No- Bake sand or Investment process is selected based on which... Bake sand and the Investment Casting Handbook by the Investment Casting Institute has the tolerance values for investment castings. Typically there
An Analysis of Industrial Technology Curriculum and Its Significance to the Casting Industry.
ERIC Educational Resources Information Center
Hauser, Roger Emmett
The purpose of this study was to determine to what extent industrial technology programs are training technologists in light of the needs of the casting industry. To determine the type of curriculum needed to prepare individuals for entry into the casting industry, and to study industrial technology programs as they relate to metal casting,…
25 CFR 217.6 - Method of casting votes.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 25 Indians 1 2010-04-01 2010-04-01 false Method of casting votes. 217.6 Section 217.6 Indians.... § 217.6 Method of casting votes. Within 30 days after an issue and any analysis provided for in §§ 217.4... superintendent in writing of the number of votes cast for and against the proposed or alternative solutions. If...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Continuous Lamination Lines and Continuous Casting Lines Complying With a Lbs/Ton Organic HAP Emissions Limit... Requirements for New and Existing Continuous Lamination Lines and Continuous Casting Lines Complying With a Lbs... with a lbs/ton organic HAP emissions limit for continuous lamination lines and continuous casting lines...
1982-08-01
components with consequent cost and weight benefits but there is traditionally a reluctance by designers to trust castings. The object of the...Specialist Meeting was to present the current state of developments of advanced casting technology, and to bring together designers and materials and...significantly in the near future. The discussion highlighted areas needing further attention, which included: — Designers need to design for casting, not
New methods and materials for molding and casting ice formations
NASA Technical Reports Server (NTRS)
Reehorst, Andrew L.; Richter, G. Paul
1987-01-01
This study was designed to find improved materials and techniques for molding and casting natural or simulated ice shapes that could replace the wax and plaster method. By utilizing modern molding and casting materials and techniques, a new methodology was developed that provides excellent reproduction, low-temperature capability, and reasonable turnaround time. The resulting casts are accurate and tough.
Quality Management and Control of Low Pressure Cast Aluminum Alloy
NASA Astrophysics Data System (ADS)
Zhang, Dianxi; Zhang, Yanbo; Yang, Xiufan; Chen, Zhaosong; Jiang, Zelan
2018-01-01
This paper briefly reviews the history of low pressure casting and summarizes the major production processes of low pressure casting. It briefly introduces the quality management and control of low pressure cast aluminum alloy. The main processes include are: preparation of raw materials, Melting, refining, physical and chemical analysis, K-mode inspection, sand core, mold, heat treatment and so on.
Does fluoroscopy improve outcomes in paediatric forearm fracture reduction?
Menachem, S; Sharfman, Z T; Perets, I; Arami, A; Eyal, G; Drexler, M; Chechik, O
2016-06-01
To compare the radiographic results of paediatric forearm fracture reduced with and without fluoroscopic enhancement to investigate whether fractures reduced under fluoroscopic guidance would have smaller residual deformities and lower rates of re-reduction and surgery. A retrospective cohort analysis was conducted comparing paediatric patients with acute forearm fracture in two trauma centres. Demographics and radiographic data from paediatric forearm fractures treated in Trauma Centre A with the aid of a C-arm fluoroscopy were compared to those treated without fluoroscopy in Trauma Centre B. Re-reduction, late displacement, post-reduction deformity, and need for surgical intervention were compared between the two groups. The cohort included 229 children (175 boys and 54 girls, mean age 9.41±3.2 years, range 1-16 years) with unilateral forearm fractures (83 manipulated with fluoroscopy and 146 without). Thirty-four (15%) children underwent re-reduction procedures in the emergency department. Fifty-three (23%) children had secondary displacement in the cast, of which 18 were operated on, 20 were re-manipulated, and the remaining 15 were kept in the cast with an acceptable deformity. Twenty-nine additional children underwent operation for reasons other than secondary displacement. There were no significant differences in re-reduction and surgery rates or in post-reduction deformities between the two groups. The use of fluoroscopy during reduction of forearm fractures in the paediatric population apparently does not have a significant effect on patient outcomes. Reductions performed without fluoroscopy were comparably accurate in correcting deformities in both coronal and sagittal planes. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
[Modified PemberSal osteotomy technique with lyophilized human allograft].
Druschel, C; Heck, K; Kraft, C; Placzek, R
2016-12-01
PemberSal osteotomy to improve femoral head coverage by rotating the acetabular roof ventrally and laterally. Insufficient coverage of the femoral head, and can be combined with other surgical procedures such as femoral intertrochanteric varus-derotation osteotomy and open reduction for developmental dysplasia and dislocation of the hip or to improve sphericity and containment in Legg-Calvé-Perthes disease. This specific acetabuloplasty can only be performed in patients with an open epiphyseal growth-plate. Increased bleeding tendency (e.g., inherited or iatrogenic); elevated anesthetic risk such as in cerebral palsy, arthrogryposis multiplex congenital, trisomies; syndromes require explicit interdisciplinary clarification to reduce perioperative risks; infections as in other elective surgeries; diseases/deformities making postoperative spica casting impossible or impractical (e.g., deformities of spinal cord or urogenital system, hernias requiring treatment); closed epiphyseal plate requires complex three-dimensional corrections of the acetabular roof (e.g., triple/periacetabular osteotomy). Osteotomy from the iliac bone to the posterior ilioischial arm of the epiphyseal growth-plate cartilage; controlled fracture of the cancellous bone without breaking the medial cortex of the iliac bone for ventrocaudal rotation of the acetabular roof. To refill and stabilize the osteotomy site, an allogenic bone-wedge is interponated and secured by a resorbable screw or kirschner wire. This method also allows more complex reconstructions of the acetabular roof, e.g., by including the pseudo-cup in a modified Rejholec technique. A spica cast is applied to immobilize the hip for 6 weeks. Afterwards physiotherapy can be performed under weight-bearing as tolerated. Radiographic check-ups every 6 months.
You, Xiaofang; Sun, Xiwen; Yang, Chunyan; Fang, Yong
2017-01-01
Abstract To investigate computed tomography (CT) characteristics of benign and malignant solitary fibrous tumors of the pleura (SFTPs). Preoperative CTs for 60 SFTP cases (49 benign and 11 malignant) with subsequently confirmed diagnoses were retrospectively analyzed. Tumor morphologies included mounded or mushroom umbrella-shape (19 cases, 31.7%), quasi-circular or oval-shape (30 cases, 50%), and growth resembling a casting mould (12 cases, 20%). Maximum tumor diameters were 1.1 to 18.9 cm (average: 6.4 ± 4.8 cm). Fifty-seven cases had clear boundaries, and 3 had partially coarse boundaries. Twenty-seven cases showed homogeneous density; 33, “geographic”-patterned inhomogeneous density; 6, calcifications; 12, intratumor blood vessels; and 3, thick nourishing peritumoral blood vessels. Pleural thickening (regular and irregular) was found adjacent to tumors in 4, compression of adjacent ribs with absorption and cortical sclerosis in 2, and location adjacent to ribs with bony destruction in 1. Four cases had a small amount of lung tissue enfolded along the boundary, 2 had multiple peritumoral pulmonary bullae, and 9 had small ipsilateral pleural effusions. Compared with benign and malignant SFTPs were larger (P < .001), had inhomogeneous density, and were more commonly associated with intratumor blood vessels and pleural effusions (P < .01). CT revealed characteristic patterns in SFTPs, including casting mould-like growth, rich blood supply, and “geographic”-patterned enhancement. In addition, larger tumor size, inhomogeneous intensities, abundant intratumor blood vessels, and pleural effusions were more common with malignancy. Lastly, multislice CT angiography can reveal feeding arteries and help guide surgical management. PMID:29245313
You, Xiaofang; Sun, Xiwen; Yang, Chunyan; Fang, Yong
2017-12-01
To investigate computed tomography (CT) characteristics of benign and malignant solitary fibrous tumors of the pleura (SFTPs).Preoperative CTs for 60 SFTP cases (49 benign and 11 malignant) with subsequently confirmed diagnoses were retrospectively analyzed.Tumor morphologies included mounded or mushroom umbrella-shape (19 cases, 31.7%), quasi-circular or oval-shape (30 cases, 50%), and growth resembling a casting mould (12 cases, 20%). Maximum tumor diameters were 1.1 to 18.9 cm (average: 6.4 ± 4.8 cm). Fifty-seven cases had clear boundaries, and 3 had partially coarse boundaries. Twenty-seven cases showed homogeneous density; 33, "geographic"-patterned inhomogeneous density; 6, calcifications; 12, intratumor blood vessels; and 3, thick nourishing peritumoral blood vessels. Pleural thickening (regular and irregular) was found adjacent to tumors in 4, compression of adjacent ribs with absorption and cortical sclerosis in 2, and location adjacent to ribs with bony destruction in 1. Four cases had a small amount of lung tissue enfolded along the boundary, 2 had multiple peritumoral pulmonary bullae, and 9 had small ipsilateral pleural effusions. Compared with benign and malignant SFTPs were larger (P < .001), had inhomogeneous density, and were more commonly associated with intratumor blood vessels and pleural effusions (P < .01).CT revealed characteristic patterns in SFTPs, including casting mould-like growth, rich blood supply, and "geographic"-patterned enhancement. In addition, larger tumor size, inhomogeneous intensities, abundant intratumor blood vessels, and pleural effusions were more common with malignancy. Lastly, multislice CT angiography can reveal feeding arteries and help guide surgical management.
Biocompatible Nanocoatings of Fluorinated Polyphosphazenes through Aqueous Assembly
Selin, Victor; Albright, Victoria; Ankner, John Francis; ...
2018-02-23
Nonionic fluorinated polyphosphazenes, such as poly[bis(trifluoroethoxy)phosphazene] (PTFEP), display superb biocompatibility, yet their deposition to surfaces has been limited to solution casting from organic solvents or thermal molding. Here in this paper, hydrophobic coatings of fluorinated polyphosphazenes are demonstrated through controlled deposition of ionic fluorinated polyphosphazenes (iFPs) from aqueous solutions using the layer-by-layer (LbL) technique. Specifically, the assemblies included poly[(carboxylatophenoxy)(trifluoroethoxy)phosphazenes] with varied content of fluorine atoms as iFPs (or poly[bis(carboxyphenoxy)phosphazene] (PCPP) as a control nonfluorinated polyphosphazene) and a variety of polycations. Hydrophobic interactions largely contributed to the formation of LbL films of iFPs with polycations, leading to linear growth and extremelymore » low water uptake. Hydrophobicity-enhanced ionic pairing within iFP/BPEI assemblies gave rise to large-amplitude oscillations in surface wettability as a function of capping layer, which were the largest for the most fluorinated iFP, while control PCPP/polycation systems remained hydrophilic regardless of the film top layer. Neutron reflectometry (NR) studies indicated superior layering and persistence of such layering in salt solution for iFP/BPEI films as compared to control PCPP/polycation systems. Hydrophobicity of iFP-capped LbL coatings could be further enhanced by using a highly porous polyester surgical felt rather than planar substrates for film deposition. Importantly, iFP/polycation coatings displayed biocompatibility which was similar to or superior to that of solution-cast coatings of a clinically validated material (PTFEP), as demonstrated by the hemolysis of the whole blood and protein adsorption studies.« less
Biocompatible Nanocoatings of Fluorinated Polyphosphazenes through Aqueous Assembly
DOE Office of Scientific and Technical Information (OSTI.GOV)
Selin, Victor; Albright, Victoria; Ankner, John Francis
Nonionic fluorinated polyphosphazenes, such as poly[bis(trifluoroethoxy)phosphazene] (PTFEP), display superb biocompatibility, yet their deposition to surfaces has been limited to solution casting from organic solvents or thermal molding. Here in this paper, hydrophobic coatings of fluorinated polyphosphazenes are demonstrated through controlled deposition of ionic fluorinated polyphosphazenes (iFPs) from aqueous solutions using the layer-by-layer (LbL) technique. Specifically, the assemblies included poly[(carboxylatophenoxy)(trifluoroethoxy)phosphazenes] with varied content of fluorine atoms as iFPs (or poly[bis(carboxyphenoxy)phosphazene] (PCPP) as a control nonfluorinated polyphosphazene) and a variety of polycations. Hydrophobic interactions largely contributed to the formation of LbL films of iFPs with polycations, leading to linear growth and extremelymore » low water uptake. Hydrophobicity-enhanced ionic pairing within iFP/BPEI assemblies gave rise to large-amplitude oscillations in surface wettability as a function of capping layer, which were the largest for the most fluorinated iFP, while control PCPP/polycation systems remained hydrophilic regardless of the film top layer. Neutron reflectometry (NR) studies indicated superior layering and persistence of such layering in salt solution for iFP/BPEI films as compared to control PCPP/polycation systems. Hydrophobicity of iFP-capped LbL coatings could be further enhanced by using a highly porous polyester surgical felt rather than planar substrates for film deposition. Importantly, iFP/polycation coatings displayed biocompatibility which was similar to or superior to that of solution-cast coatings of a clinically validated material (PTFEP), as demonstrated by the hemolysis of the whole blood and protein adsorption studies.« less
Ageless Aluminum-Cerium-Based Alloys in High-Volume Die Casting for Improved Energy Efficiency
Stromme, Eric T.; Henderson, Hunter B.; Sims, Zachary C.; ...
2018-04-25
Strong chemical reactions between Al and Ce lead to the formation of intermetallics with exceptional thermal stability. The rapid formation of intermetallics directly from the liquid phase during solidification of Al-Ce alloys leads to an ultrafine microconstituent structure that effectively strengthens as-cast alloys without further microstructural optimization via thermal processing. Die casting is a high-volume manufacturing technology that accounts for greater than 40% of all cast Al products, whereas Ce is highly overproduced as a waste product of other rare earth element (REE) mining. Reducing heat treatments would stimulate significant improvements in manufacturing energy efficiency, exceeding (megatonnes/year) per large-scale heat-treatmentmore » line. In this study, multiple compositions were evaluated with wedge mold castings to test the sensitivity of alloys to the variable solidification rate inherent in high-pressure die casting. Once a suitable composition was determined, it was successfully demonstrated at 800 lbs/h in a 600-ton die caster, after which the as-die cast parts performed similarly to ubiquitous A380 in the same geometry without requiring heat treatment. Furthermore, this work demonstrates the compatibility of Al REE alloys with high-volume die-casting applications with minimal heat treatments.« less
Prediction of Shrinkage Porosity Defect in Sand Casting Process of LM25
NASA Astrophysics Data System (ADS)
Rathod, Hardik; Dhulia, Jay K.; Maniar, Nirav P.
2017-08-01
In the present worldwide and aggressive environment, foundry commercial enterprises need to perform productively with least number of rejections and create casting parts in shortest lead time. It has become extremely difficult for foundry industries to meet demands of defects free casting and meet strict delivery schedules. The process of casting solidification is complex in nature. Prediction of shrinkage defect in metal casting is one of the critical concern in foundries and is one of the potential research areas in casting. Due to increasing pressure to improve quality and to reduce cost, it is very essential to upgrade the level of current methodology used in foundries. In the present research work, prediction methodology of shrinkage porosity defect in sand casting process of LM25 using experimentation and ANSYS is proposed. The objectives successfully achieved are prediction of shrinkage porosity distribution in Al-Si casting and determining effectiveness of investigated function for predicting shrinkage porosity by correlating results of simulating studies to those obtained experimentally. The real-time application of the research reflects from the fact that experimentation is performed on 9 different Y junctions at foundry industry and practical data obtained from experimentation are used for simulation.
Ageless Aluminum-Cerium-Based Alloys in High-Volume Die Casting for Improved Energy Efficiency
NASA Astrophysics Data System (ADS)
Stromme, Eric T.; Henderson, Hunter B.; Sims, Zachary C.; Kesler, Michael S.; Weiss, David; Ott, Ryan T.; Meng, Fanqiang; Kassoumeh, Sam; Evangelista, James; Begley, Gerald; Rios, Orlando
2018-06-01
Strong chemical reactions between Al and Ce lead to the formation of intermetallics with exceptional thermal stability. The rapid formation of intermetallics directly from the liquid phase during solidification of Al-Ce alloys leads to an ultrafine microconstituent structure that effectively strengthens as-cast alloys without further microstructural optimization via thermal processing. Die casting is a high-volume manufacturing technology that accounts for greater than 40% of all cast Al products, whereas Ce is highly overproduced as a waste product of other rare earth element (REE) mining. Reducing heat treatments would stimulate significant improvements in manufacturing energy efficiency, exceeding (megatonnes/year) per large-scale heat-treatment line. In this study, multiple compositions were evaluated with wedge mold castings to test the sensitivity of alloys to the variable solidification rate inherent in high-pressure die casting. Once a suitable composition was determined, it was successfully demonstrated at 800 lbs/h in a 600-ton die caster, after which the as-die cast parts performed similarly to ubiquitous A380 in the same geometry without requiring heat treatment. This work demonstrates the compatibility of Al REE alloys with high-volume die-casting applications with minimal heat treatments.
Ageless Aluminum-Cerium-Based Alloys in High-Volume Die Casting for Improved Energy Efficiency
NASA Astrophysics Data System (ADS)
Stromme, Eric T.; Henderson, Hunter B.; Sims, Zachary C.; Kesler, Michael S.; Weiss, David; Ott, Ryan T.; Meng, Fanqiang; Kassoumeh, Sam; Evangelista, James; Begley, Gerald; Rios, Orlando
2018-04-01
Strong chemical reactions between Al and Ce lead to the formation of intermetallics with exceptional thermal stability. The rapid formation of intermetallics directly from the liquid phase during solidification of Al-Ce alloys leads to an ultrafine microconstituent structure that effectively strengthens as-cast alloys without further microstructural optimization via thermal processing. Die casting is a high-volume manufacturing technology that accounts for greater than 40% of all cast Al products, whereas Ce is highly overproduced as a waste product of other rare earth element (REE) mining. Reducing heat treatments would stimulate significant improvements in manufacturing energy efficiency, exceeding (megatonnes/year) per large-scale heat-treatment line. In this study, multiple compositions were evaluated with wedge mold castings to test the sensitivity of alloys to the variable solidification rate inherent in high-pressure die casting. Once a suitable composition was determined, it was successfully demonstrated at 800 lbs/h in a 600-ton die caster, after which the as-die cast parts performed similarly to ubiquitous A380 in the same geometry without requiring heat treatment. This work demonstrates the compatibility of Al REE alloys with high-volume die-casting applications with minimal heat treatments.
Ageless Aluminum-Cerium-Based Alloys in High-Volume Die Casting for Improved Energy Efficiency
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stromme, Eric T.; Henderson, Hunter B.; Sims, Zachary C.
Strong chemical reactions between Al and Ce lead to the formation of intermetallics with exceptional thermal stability. The rapid formation of intermetallics directly from the liquid phase during solidification of Al-Ce alloys leads to an ultrafine microconstituent structure that effectively strengthens as-cast alloys without further microstructural optimization via thermal processing. Die casting is a high-volume manufacturing technology that accounts for greater than 40% of all cast Al products, whereas Ce is highly overproduced as a waste product of other rare earth element (REE) mining. Reducing heat treatments would stimulate significant improvements in manufacturing energy efficiency, exceeding (megatonnes/year) per large-scale heat-treatmentmore » line. In this study, multiple compositions were evaluated with wedge mold castings to test the sensitivity of alloys to the variable solidification rate inherent in high-pressure die casting. Once a suitable composition was determined, it was successfully demonstrated at 800 lbs/h in a 600-ton die caster, after which the as-die cast parts performed similarly to ubiquitous A380 in the same geometry without requiring heat treatment. Furthermore, this work demonstrates the compatibility of Al REE alloys with high-volume die-casting applications with minimal heat treatments.« less
Abduo, Jaafar
2017-01-01
This study evaluated and compared the effect of conventional and digital wax-ups on three lateral occlusion variables: contact number, contact area, and steepness. Dental casts of 10 patients with Angle Class I relationship were included in the study. All patients required fixed prosthodontic treatment that would affect lateral occlusion. The casts of all patients received conventional and digital wax-ups. For pretreatment, conventional wax-up, and digital wax-up casts, contact number, contact area, and occlusion steepness were measured at four lateral positions, that is, at excursions of 0.5, 1.0, 2.0, and 3.0 mm from maximal intercuspation. Lateral occlusion scheme variables were affected by use of diagnostic wax-ups. For all types of casts, contact number decreased as excursion increased. The two types of wax-ups had similar contact number patterns, and contact number was significantly greater for these casts than for pretreatment casts in the earlier stages of excursion. Similarly, contact area gradually decreased with increasing excursion in the pretreatment and conventional and digital wax-up casts. There was only a minimal decrease in occlusion steepness as excursion increased. However, lateral occlusion was generally steeper for digital wax-up casts.
Micro-structure and Air-tightness of Squeeze Casting Motor housing for New Energy Vehicle
NASA Astrophysics Data System (ADS)
Jiang, Y. F.; Kang, Z. Q.; Jiang, W. F.; Wang, K. W.; Sha, D. L.; Li, M. L.; Sun, J.
2018-05-01
In order to improve the performance of automobile parts, the influence of squeeze casting process parameters on casting defects, material structure and air-tightness of aluminum alloy motor housing for new energy vehicle was studied. The results show that the density of the castings increases with the increase in pressure and mold temperature. With increase in pouring temperature, it increases first and then decreases. Pressure has the greatest influence on the density of the castings. Under a certain pressure, with moderate increase in casting temperature and mold temperature, the grain growth begins to increase; the dendrites become less, the new α - Al grains are spherical and granular, the micro-structure is uniform. Also, with increase in pressure, this effect is more pronounced, the air-tightness of castings improve. In conclusion, when the pressure is 110MPa, pouring temperature is 680° C, mold temperature is 280° C, pressure holding for 30s, and punch speed of 0.1m/s, there is no clear shrinkage in the casting, the structure is uniform, the qualified rate of air-tightness of production reaches 86%, and the performance is excellent.
Fabrication of silk fibroin film using centrifugal casting technique for corneal tissue engineering.
Lee, Min Chae; Kim, Dong-Kyu; Lee, Ok Joo; Kim, Jung-Ho; Ju, Hyung Woo; Lee, Jung Min; Moon, Bo Mi; Park, Hyun Jung; Kim, Dong Wook; Kim, Su Hyeon; Park, Chan Hum
2016-04-01
Films prepared from silk fibroin have shown potential as biomaterials in tissue engineering applications for the eye. Here, we present a novel process for fabrication of silk fibroin films for corneal application. In this work, fabrication of silk fibroin films was simply achieved by centrifugal force. In contrast to the conventional dry casting method, we carried out the new process in a centrifuge with a rotating speed of 4000 rpm, where centrifugal force was imposed on an aluminum tube containing silk fibroin solution. In the present study, we also compared the surface roughness, mechanical properties, transparency, and cell proliferation between centrifugal and dry casting method. In terms of surface morphology, films fabricated by the centrifugal casting have less surface roughness than those by the dry casting. For elasticity and transparency, silk fibroin films obtained from the centrifugal casting had favorable results compared with those prepared by dry casting. Furthermore, primary human corneal keratocytes grew better in films prepared by the centrifugal casting. Therefore, our results suggest that this new fabrication process for silk fibroin films offers important potential benefits for corneal tissue regeneration. © 2015 Wiley Periodicals, Inc.
AMCC casting development. Volume 1: Executive Summary
NASA Technical Reports Server (NTRS)
1995-01-01
The Advanced Combustion Chamber Casting (AMCC) has been a technically challenging part due to its size, configuration, and alloy type. The height and weight of the wax pattern assembly necessitated the development of a hollow gating system to ensure structural integrity of the shell throughout the investment process. The complexity in the jacket area of the casting required the development of an innovative casting technology that PCC has termed 'TGC' or Thermal Gradient Control. This method, of setting up thermal gradients in the casting during solidification, represents a significant process improvement for PCC and has been successfully implemented on other programs. Metallurgical integrity of the final four castings was very good. Only the areas of the parts that utilized 'TGC Shape & Location System #2' showed any significant areas of microshrinkage when evaluated by non-destructive tests. Alumina oxides detected by FPI on the 'float' surfaces (top sid surfaces of the casting during solidification) of the part were almost entirely less than the acceptance criteria of .032 inches in diameter. Destructive chem mill of the castings was required to determine the effect of the process variables used during the processing of these last four parts (with the exception of the 'Shape & Location of TGC' variable).
Development of cast alumina-forming austenitic stainless steels
Muralidharan, G.; Yamamoto, Y.; Brady, M. P.; ...
2016-09-06
Cast Fe-Ni-Cr chromia-forming austenitic stainless steels with Ni levels up to 45 wt. % are used at high temperatures in a wide range of industrial applications that demand microstructural stability, corrosion resistance, and creep strength. Although alumina scales offer better corrosion protection at these temperatures, designing cast austenitic alloys that form a stable alumina scale and achieve creep strength comparable to existing cast chromia-forming alloys is challenging. This work outlines the development of cast Fe-Ni-Cr-Al austenitic stainless steels containing about 25 wt. % Ni with good creep strength and the ability to form a protective alumina scale for use atmore » temperatures up to 800 C - 850 C in H 2O-, S-, and C- containing environments. Creep properties of the best alloy were comparable to that of HK-type cast chromia-forming alloy along with improved oxidation resistance typical of alumina-forming alloys. Lastly, challenges in the design of cast alloys and a potential path to increasing the temperature capability are discussed.« less
NASA Astrophysics Data System (ADS)
Kim, Cheol-Woo; Cho, Jae-Ik; Choi, Se-Weon; Kim, Young-Chan; Kang, Chang-Seog
Recently, demand of aluminum alloys for use in high thermal conductivity application is increases but the most aluminum die casting alloys exhibit very lower thermal properties because of their high concentrations of alloying elements. However, those alloying elements are essential to obtain sufficient fluidity and mechanical strength. Therefore, the purpose of this study is to analyze the effect of alloying elements in die casting alloys, Si, Cu, Mg, Fe and Mn, in thermal conductivity, die casting characteristics and mechanical properties and find out the appropriate amount of each alloying element for development of heat sink component. The results showed that Mn had the most deleterious effect in thermal conductivity and Si and Fe contents were important to improve strength and limit casting defects, such as hot tearing and die soldering. The alloy with 0.2 1.0wt%Cu, 0.3 0.6wt%Fe and 1.0 2.0wt%Si showed very good combination of high thermal conductivity and good casting characteristics.
Development, fabrication and test of a high purity silica heat shield
NASA Technical Reports Server (NTRS)
Rusert, E. L.; Drennan, D. N.; Biggs, M. S.
1978-01-01
A highly reflective hyperpure ( 25 ppm ion impurities) slip cast fused silica heat shield material developed for planetary entry probes was successfully scaled up. Process development activities for slip casting large parts included green strength improvements, casting slip preparation, aggregate casting, strength, reflectance, and subscale fabrication. Successful fabrication of a one-half scale Saturn probe (shape and size) heat shield was accomplished while maintaining the silica high purity and reflectance through the scale-up process. However, stress analysis of this original aggregate slip cast material indicated a small margin of safety (MS. = +4%) using a factor of safety of 1.25. An alternate hyperpure material formulation to increase the strength and toughness for a greater safety margin was evaluated. The alternate material incorporates short hyperpure silica fibers into the casting slip. The best formulation evaluated has a 50% by weight fiber addition resulting in an 80% increase in flexural strength and a 170% increase in toughness over the original aggregate slip cast materials with comparable reflectance.
Development of Cast Alumina-Forming Austenitic Stainless Steels
NASA Astrophysics Data System (ADS)
Muralidharan, G.; Yamamoto, Y.; Brady, M. P.; Walker, L. R.; Meyer, H. M., III; Leonard, D. N.
2016-11-01
Cast Fe-Ni-Cr chromia-forming austenitic stainless steels with Ni levels up to 45 wt.% are used at high temperatures in a wide range of industrial applications that demand microstructural stability, corrosion resistance, and creep strength. Although alumina scales offer better corrosion protection at these temperatures, designing cast austenitic alloys that form a stable alumina scale and achieve creep strength comparable to existing cast chromia-forming alloys is challenging. This work outlines the development of cast Fe-Ni-Cr-Al austenitic stainless steels containing about 25 wt.% Ni with good creep strength and the ability to form a protective alumina scale for use at temperatures up to 800-850°C in H2O-, S-, and C-containing environments. Creep properties of the best alloy were comparable to that of HK-type cast chromia-forming alloys along with improved oxidation resistance typical of alumina-forming alloys. Challenges in the design of cast alloys and a potential path to increasing the temperature capability are discussed.
Thin Gauge Twin-Roll Casting, Process Capabilities and Product Quality
NASA Astrophysics Data System (ADS)
Daaland, O.; Espedal, A. B.; Nedreberg, M. L.; Alvestad, I.
Traditionally industrial twin roll casters have been operated at gauges 6-10 mm, depending on the type of caster and the final product requirements. Over the past few years it has become apparent that a significant increase in productivity can be achieved when the casting gauge is reduced. Hydro Aluminium embarked on an extensive research and development, thin gauge casting programme, in the beginning of the 1990's and this paper presents some results from a five year lasting project (joint programme between Hydro Aluminium a.s. and Lauener Engineering). Based on more than 400 casting trials the major benefits and limitations of casting at reduced gauge and increased speed are outlined. Important aspects related to process development and product quality are discussed including: productivity and limitations, surface defects, microstructural characteristics, cooling rates and dendrite structure, segregation behaviour and mechanical properties after thermo-mechanical processing. Results for casting of several alloys are given. Additionally, numerical modelling results of the strip casting process are included.
Simulation of cracking cores when molding piston components
NASA Astrophysics Data System (ADS)
Petrenko, Alena; Soukup, Josef
2014-08-01
The article deals with pistons casting made from aluminum alloy. Pistons are casting at steel mold with steel core. The casting is provided by gravity casting machine. The each machine is equipped by two metal molds, which are preheated above temperature 160 °C before use. The steel core is also preheated by flame. The metal molds and cores are heated up within the casting process. The temperature of the metal mold raise up to 200 °C and temperature of core is higher. The surface of the core is treated by nitration. The mold and core are cooled down by water during casting process. The core is overheated and its top part is finally cracked despite its intensive water-cooling. The life time cycle of the core is decreased to approximately 5 to 15 thousands casting, which is only 15 % of life time cycle of core for production of other pistons. The article presents the temperature analysis of the core.
NASA Astrophysics Data System (ADS)
Mukunda, P. G.; Shailesh, Rao A.; Rao, Shrikantha S.
2010-02-01
Although the manner in which the molten metal flows plays a major role in the formation of the uniform cylinder in centrifugal casting, not much information is available on this topic. The flow in the molten metal differs at various rotational speeds, which in turn affects the final casting. In this paper, the influence of the flow of molten metal of hyper eutectic Al-2Si alloys at various rotational speeds is discussed. At an optimum speed of 800 rpm, a uniform cylinder was formed. For the rotational speeds below and above these speeds, an irregular shaped casting was formed, which is mainly due to the influence of melt. Primary á-Al particles were formed in the tube periphery at low rotational speed, and their sizes and shapes were altered with changes in rotational speeds. The wear test for the inner surface of the casting showed better wear properties for the casting prepared at the optimum speed of rotation.
Effect of Heating Time on Hardness Properties of Laser Clad Gray Cast Iron Surface
NASA Astrophysics Data System (ADS)
Norhafzan, B.; Aqida, S. N.; Mifthal, F.; Zulhishamuddin, A. R.; Ismail, I.
2018-03-01
This paper presents effect of heating time on cladded gray cast iron. In this study, the effect of heating time on cladded gray cast iron and melted gray cast iron were analysed. The gray cast iron sample were added with mixed Mo-Cr powder using laser cladding technique. The mixed Mo and Cr powder was pre-placed on gray cast iron surface. Modified layer were sectioned using diamond blade cutter and polish using SiC abrasive paper before heated. Sample was heated in furnace for 15, 30 and 45 minutes at 650 °C and cool down in room temperature. Metallographic study was conduct using inverted microscope while surface hardness properties were tested using Wilson hardness test with Vickers scale. Results for metallographic study showed graphite flakes within matrix of pearlite. The surface hardness for modified layer decreased when increased heating time process. These findings are significant to structure stability of laser cladded gray cast iron with different heating times.
The development of ultrahigh strength low alloy cast steels with increased toughness
NASA Astrophysics Data System (ADS)
Lynch, Paul C.
This work describes the initial work on the development of the next generation of ultrahigh strength low alloy (UHSLA) cast steels. These UHSLA cast steels have both ultrahigh strength levels and good impact toughness. The influence of heat treatment, secondary processing using hot isostatic processing (HIP), and chemical composition on the microstructure and properties of UHSLA cast steels have been evaluated. The extent of microsegregation reduction expected during the heat treatment of UHSLA cast steels has also been estimated by diffusion modeling. This new family of UHSLA cast steels is similar in composition and properties to UHSLA wrought steels. However, the heat treatment and secondary processing of the UHSLA cast steels is used to develop microstructures and properties typically developed through thermomechanical processing and heat treatment for wrought UHSLA steels. Two martensitic UHSLA steels, 4340+ (silicon modified 4340) and ES-1 were investigated for this study. For the 4340+ alloy, heat treatment variables evaluated include homogenization temperature and time, tempering temperature, and austempering temperature and time. For the ES-1 alloy, heat treatment variables evaluated include homogenization temperature and time, austenization temperature, cryogenic treatment, and tempering temperature. The effect of high temperature hot isostatic processing (HIP) on the 4340+ and ES- 1 alloys was also investigated. Tensile properties, charpy v-notch impact toughness (CVN), microstructures, and fractographs have all been characterized after heat treatment. The effects of HIP on microporosity reduction in the ES-1 alloy were also investigated. The experiments carried out on the investment cast 4340+ alloy have shown that increasing the homogenization temperature can increase CVN without changing the ultimate tensile strength (UTS) or yield strength (YS) of the cast material. By replacing the homogenization step in the conventional heat treatment process with a high temperature HIP treatment, both the CVN and ductility of the alloy was found to increase while maintaining comparable ultimate tensile strength (UTS) and yield strength (YS) levels as compared to the original homogenization treatment. Austempering the (IC) 4340+ material led to a significant increase in CVN and ductility at the expense of UTS and yield strength as the primarily martensitic microstructure was converted to a mixed martensitic-bainitic structure. An initial heat of induction melted, aluminum deoxidized investment cast ES-1 with 0.06 wt % of aluminum showed that the average -40°F and +72°F impact toughness, % elongation, and UTS and YS of the fully heat treated investment cast + HIP ES-1 material lagged significantly behind that of the vacuum degassed cast + HIP ES-1 ingot material. Even though the % elongation and impact toughness of the investment cast ES-1 material changed between heat treatment conditions, the average UTS and YS values remained relatively unchanged throughout the heat treatments for the investment cast study. Etched micrographs of the investment cast ES-1 material showed evidence of significant differences in microsegregation reduction between the samples homogenized at 2125°F for 4 hours and those not homogenized at 2125°F for 4 hours. SEM fracture surface work performed on the investment cast material clearly showed that the induction melted investment and aluminum killed cast material contained significant amounts of MnS and Al2O3 inclusions that were not discovered in the vacuum degassed cast ingot material. Lastly, the results of a third heat of induction melted, aluminum deoxidized investment cast ES-1 material possessing just 0.01wt% of aluminum showed that the decrease in aluminum content from the first experimental heat did not improve the mechanical properties of the investment cast material. (Abstract shortened by UMI.)
Numerical simulation and optimization of casting process for complex pump
NASA Astrophysics Data System (ADS)
Liu, Xueqin; Dong, Anping; Wang, Donghong; Lu, Yanling; Zhu, Guoliang
2017-09-01
The complex shape of the casting pump body has large complicated structure and uniform wall thickness, which easy give rise to casting defects. The numerical simulation software ProCAST is used to simulate the initial top gating process, after analysis of the material and structure characteristics of the high-pressure pump. The filling process was overall smooth, not there the water shortage phenomenon. But the circular shrinkage defects appear at the bottom of casting during solidification process. Then, the casting parameters were optimized and adding cold iron in the bottom. The shrinkage weight was reduced from 0.00167g to 0.0005g. The porosity volume was reduced from 1.39cm3 to 0.41cm3. The optimization scheme is simulated and actual experimented. The defect has been significantly improved.
Tuning the properties of polyhydroxybutyrate films using acetic acid via solvent casting
Anbukarasu, Preetam; Sauvageau, Dominic; Elias, Anastasia
2015-01-01
Biodegradable polyhydroxybutyrate (PHB) films were fabricated using acetic acid as an alternative to common solvents such as chloroform. The PHB films were prepared using a solvent casting process at temperatures ranging from 80 °C to 160 °C. The crystallinity, mechanical properties and surface morphology of the films cast at different temperatures were characterized and compared to PHB films cast using chloroform as a solvent. Results revealed that the properties of the PHB film varied considerably with solvent casting temperature. In general, samples processed with acetic acid at low temperatures had comparable mechanical properties to PHB cast using chloroform. This acetic acid based method is environmentally friendly, cost efficient and allows more flexible processing conditions and broader ranges of polymer properties than traditional methods. PMID:26640089
Tuning the properties of polyhydroxybutyrate films using acetic acid via solvent casting
NASA Astrophysics Data System (ADS)
Anbukarasu, Preetam; Sauvageau, Dominic; Elias, Anastasia
2015-12-01
Biodegradable polyhydroxybutyrate (PHB) films were fabricated using acetic acid as an alternative to common solvents such as chloroform. The PHB films were prepared using a solvent casting process at temperatures ranging from 80 °C to 160 °C. The crystallinity, mechanical properties and surface morphology of the films cast at different temperatures were characterized and compared to PHB films cast using chloroform as a solvent. Results revealed that the properties of the PHB film varied considerably with solvent casting temperature. In general, samples processed with acetic acid at low temperatures had comparable mechanical properties to PHB cast using chloroform. This acetic acid based method is environmentally friendly, cost efficient and allows more flexible processing conditions and broader ranges of polymer properties than traditional methods.
Carmichael, Kelly D; Goucher, Nicholas R
2006-01-01
This report describes a case in which a pediatric patient wounded his ankle when he stuck an object inside the cast while trying to scratch himself. The wound became infected and resulted in a limb-threatening abscess. Although most patients treated with casts do not have any significant problems, it is important to emphasize cast care instructions to young patients and their parents. In addition, it may be equally important to advise patients about safe methods to alleviate itching, such as blowing cool air under the cast. In this way, the risk of serious infectious complications can be minimized.
Shah, Shabir A; Naqash, Talib Amin; Padmanabhan, T V; Subramanium; Lambodaran; Nazir, Shazana
2014-03-01
The sole objective of casting procedure is to provide a metallic duplication of missing tooth structure, with as great accuracy as possible. The ability to produce well fitting castings require strict adherence to certain fundamentals. A study was undertaken to comparatively evaluate the effect on casting accuracy by subjecting the invested wax patterns to burnout after different time intervals. The effect on casting accuracy using metal ring into a pre heated burnout furnace and using split ring was also carried. The readings obtained were tabulated and subjected to statistical analysis.
Dai, F F; Liu, Y; Xu, T M; Chen, G
2018-04-18
To explore a cone beam computed tomography (CBCT)-independent method for mandibular digital dental cast superimposition to evaluate three-dimensional (3D) mandibular tooth movement after orthodontic treatment in adults, and to evaluate the accuracy of this method. Fifteen post-extraction orthodontic treatment adults from the Department of Orthodontics, Peking University School and Hospital of Stomatology were included. All the patients had four first premolars extracted, and were treated with straight wire appliance. The pre- and post-treatment plaster dental casts and craniofacial CBCT scans were obtained. The plaster dental casts were transferred to digital dental casts by 3D laser scanning, and lateral cephalograms were created from the craniofacial CBCT scans by orthogonal projection. The lateral cephalogram-based mandibular digital dental cast superimposition was achieved by sequential maxillary dental cast superimposition registered on the palatal stable region, occlusal transfer, and adjustment of mandibular rotation and translation obtained from lateral cephalogram superimposition. The accuracy of the lateral cephalogram-based mandibular digital dental cast superimposition method was evaluated with the CBCT-based mandibular digital dental cast superimposition method as the standard reference. After mandibular digital dental cast superimposition using both methods, 3D coordinate system was established, and 3D displacements of the lower bilateral first molars, canines and central incisors were measured. Differences between the two superimposition methods in tooth displacement measurements were assessed using the paired t-test with the level of statistical significance set at P<0.05. No significant differences were found between the lateral cephalogram-based and CBCT-based mandibular digital dental cast superimposition methods in 3D displacements of the lower first molars, and sagittal and vertical displacements of the canines and central incisors; transverse displacements of the canines and central incisors differed by (0.3±0.5) mm with statistical significance. The lateral cephalogram-based mandibular digital dental cast superimposition method has the similar accuracy as the CBCT-based mandibular digital dental cast superimposition method in 3D evaluation of mandibular orthodontic tooth displacement, except for minor differences for the transverse displacements of anterior teeth. This method is applicable to adult patients with conventional orthodontic treatment records, especially the previous precious orthodontic data in the absence of CBCT scans.
Accuracy of single-abutment digital cast obtained using intraoral and cast scanners.
Lee, Jae-Jun; Jeong, Ii-Do; Park, Jin-Young; Jeon, Jin-Hun; Kim, Ji-Hwan; Kim, Woong-Chul
2017-02-01
Scanners are frequently used in the fabrication of dental prostheses. However, the accuracy of these scanners is variable, and little information is available. The purpose of this in vitro study was to compare the accuracy of cast scanners with that of intraoral scanners by using different image impression techniques. A poly(methyl methacrylate) master model was fabricated to replicate a maxillary first molar single-abutment tooth model. The master model was scanned with an accurate engineering scanner to obtain a true value (n=1) and with 2 intraoral scanners (CEREC Bluecam and CEREC Omnicam; n=6 each). The cast scanner scanned the master model and duplicated the dental stone cast from the master model (n=6). The trueness and precision of the data were measured using a 3-dimensional analysis program. The Kruskal-Wallis test was used to compare the different sets of scanning data, followed by a post hoc Mann-Whitney U test with a significance level modified by Bonferroni correction (α/6=.0083). The type 1 error level (α) was set at .05. The trueness value (root mean square: mean ±standard deviation) was 17.5 ±1.8 μm for the Bluecam, 13.8 ±1.4 μm for the Omnicam, 17.4 ±1.7 μm for cast scanner 1, and 12.3 ±0.1 μm for cast scanner 2. The differences between the Bluecam and the cast scanner 1 and between the Omnicam and the cast scanner 2 were not statistically significant (P>.0083), but a statistically significant difference was found between all the other pairs (P<.0083). The precision of the scanners was 12.7 ±2.6 μm for the Bluecam, 12.5 ±3.7 μm for the Omnicam, 9.2 ±1.2 μm for cast scanner 1, and 6.9 ±2.6 μm for cast scanner 2. The differences between Bluecam and Omnicam and between Omnicam and cast scanner 1 were not statistically significant (P>.0083), but there was a statistically significant difference between all the other pairs (P<.0083). An Omnicam in video image impression had better trueness than a cast scanner but with a similar level of precision. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-07-01
... to alloying or casting of nonferrous metals is limited to alloying or casting of hot metal directly... cooling is included in the aluminum forming, nonferrous metals forming, or metal molding and casting point...
Stoddard, Nathan G [Gettysburg, PA
2011-11-01
Methods and apparatuses are provided for casting silicon for photovoltaic cells and other applications. With such methods and apparatuses, a cast body of monocrystalline silicon may be formed that is free of, or substantially free of, radially-distributed impurities and defects and having at least two dimensions that are each at least about 35 cm is provided.
Evaluation of three variables affecting the casting of base metal alloys.
Wight, T A; Grisius, R J; Gaugler, R W
1980-04-01
All the vented samples with sprue widths of 2 mm or more were defect free, whereas the corresponding unvented samples had extensive voids and porosity in all but one casting. All castings with a sprue width of 1 mm were defective regardless of whether or not vents were used. The thickness of the investment above the pattern had no effect on casting results.
Study of the pore structure of ceramics prepared by the slip casting method
NASA Technical Reports Server (NTRS)
Guzman, I. Y.; Dobysh, A. V.
1984-01-01
The porosity of the slip cast Si3N4 is similar to that of pressed Si3N4 formed at 2500 kg/sq cm. The porosity of cast Si oxynitride is equivalent to that of samples stressed at 10,000 kg/sq cm. Crucibles formed from these materials by slip casting have high thermal shock and corrosion resistance.
Cast dielectric composite linear accelerator
Sanders, David M [Livermore, CA; Sampayan, Stephen [Manteca, CA; Slenes, Kirk [Albuquerque, NM; Stoller, H M [Albuquerque, NM
2009-11-10
A linear accelerator having cast dielectric composite layers integrally formed with conductor electrodes in a solventless fabrication process, with the cast dielectric composite preferably having a nanoparticle filler in an organic polymer such as a thermosetting resin. By incorporating this cast dielectric composite the dielectric constant of critical insulating layers of the transmission lines of the accelerator are increased while simultaneously maintaining high dielectric strengths for the accelerator.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuyucak, Selcuk; Li, Delin
2013-12-31
Inclusions in steel castings can cause rework, scrap, poor machining, and reduced casting performance, which can obviously result in excess energy consumption. Significant progress in understanding inclusion source, formation and control has been made. Inclusions can be defined as non-metallic materials such as refractory, sand, slag, or coatings, embedded in a metallic matrix. This research project has focused on the mold filling aspects to examine the effects of pouring methods and gating designs on the steel casting cleanliness through water modeling, computer modeling, and melting/casting experiments. Early in the research project, comprehensive studies of bottom-pouring water modeling and low-alloy steelmore » casting experiments were completed. The extent of air entrainment in bottom-poured large castings was demonstrated by water modeling. Current gating systems are designed to prevent air aspiration. However, air entrainment is equally harmful and no prevention measures are in current practice. In this study, new basin designs included a basin dam, submerged nozzle, and nozzle extension. The entrained air and inclusions from the gating system were significantly reduced using the new basin method. Near the end of the project, there has been close collaboration with Wescast Industries Inc., a company manufacturing automotive exhaust components. Both computer modeling using Magma software and melting/casting experiments on thin wall turbo-housing stainless steel castings were completed in this short period of time. Six gating designs were created, including the current gating on the pattern, non-pressurized, partially pressurized, naturally pressurized, naturally pressurized without filter, and radial choke gating without filter, for Magma modeling. The melt filling velocity and temperature were determined from the modeling. Based on the simulation results, three gating designs were chosen for further melting and casting experiments on the same casting pattern using the lip pouring method. It was observed again that gating designs greatly influenced the melt filling velocity and the number of inclusion defects. The radial choked gating showed improvements in casting cleanliness and yield over the other gatings, even though no mold filters were used in the gating system.« less
The effects of different types of investments on the alpha-case layer of titanium castings.
Guilin, Yu; Nan, Li; Yousheng, Li; Yining, Wang
2007-03-01
Different types of investments affect the formation of the alpha-case (alpha-case) layer on titanium castings. This alpha-case layer may possibly alter the mechanical properties of cast titanium, which may influence the fabrication of removable and fixed prostheses. The formation mechanism for the alpha-case layer is not clear. The aim of this study was to evaluate the effect of 3 types of investments on the microstructure, composition, and microhardness of the alpha-case layer on titanium castings. Fifteen wax columns with a diameter of 5 mm and a length of 40 mm were divided into 3 groups of 5 patterns each. Patterns were invested using 3 types of investment materials, respectively, and were cast in pure titanium. The 3 types of materials tested were SiO(2)-, Al(2)O(3)-, and MgO-based investments. All specimens were sectioned and prepared for metallographic observation. The microstructure and composition of the surface reaction layer of titanium castings were investigated by scanning electron microscopy (SEM) and electron probe microanalysis (EPMA). The surface microhardness (VHN) for all specimens was measured using a hardness testing machine, and a mean value for each group was calculated. The alpha-case layer on titanium castings invested with SiO(2)-, Al(2)O(3)-, and MgO-based investments consisted of 3 layers-namely, the oxide layer, alloy layer, and hardening layer. In this study, the oxide layer and alloy layer were called the reaction layer. The thickness of the reaction layer for titanium castings using SiO(2)-, Al(2)O(3)-, and MgO-based investments was approximately 80 microm, 50 microm, and 14 microm, respectively. The surface microhardness of titanium castings made with SiO(2)-based investments was the highest, and that with MgO-based investments was the lowest. The type of investment affects the microstructure and microhardness of the alpha-case layer of titanium castings. Based on the thickness of the surface reaction layer and the surface microhardness of titanium castings, MgO-based investment materials may be the best choice for casting these materials.
Koike, Mari; Hummel, Susan K; Ball, John D; Okabe, Toru
2012-06-01
Although pure titanium is known to have good biocompatibility, a titanium alloy with better strength is needed for fabricating clinically acceptable, partial removable dental prosthesis (RDP) frameworks. The mechanical properties of an experimental Ti-5Al-5Cu alloy cast with a 2-step investment technique were examined for RDP framework applications. Patterns for tests for various properties and denture frameworks for a preliminary trial casting were invested with a 2-step coating method using 2 types of mold materials: a less reactive spinel compound (Al(2)O(3)·MgO) and a less expensive SiO(2)-based material. The yield and tensile strength (n=5), modulus of elasticity (n=5), elongation (n=5), and hardness (n=8) of the cast Ti-5Al-5Cu alloy were determined. The external appearance and internal porosities of the preliminary trial castings of denture frameworks (n=2) were examined with a conventional dental radiographic unit. Cast Ti-6Al-4V alloy and commercially pure titanium (CP Ti) were used as controls. The data for the mechanical properties were statistically analyzed with 1-way ANOVA (α=.05). The yield strength of the cast Ti-5Al-5Cu alloy was 851 MPa and the hardness was 356 HV. These properties were comparable to those of the cast Ti-6Al-4V and were higher than those of CP Ti (P<.05). One of the acrylic resin-retention areas of the Ti-5Al-5Cu frameworks was found to have been incompletely cast. The cast biocompatible experimental Ti-5Al-5Cu alloy exhibited high strength when cast with a 2-step coating method. With a dedicated study to determine the effect of sprue design on the quality of castings, biocompatible Ti-5Al-5Cu RDP frameworks for a clinical trial can be produced. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Riahi, Samira; Niroumand, Behzad; Dorri Moghadam, Afsaneh; Rohatgi, Pradeep K.
2018-05-01
In the present study, variation in surface wetting behavior of a hypoeutectic cast iron with its microstructural features and surface roughness was investigated. Samples with an identical composition, i.e. Fe-3.2 wt%C.E., and different microstructures (a gray cast iron with A-type flake graphite and a white cast iron) were fabricated by gravity casting of molten cast iron in a chill mold at different cooling rates. A variation of surface roughness was also developed by polishing, a four-stage electroetching and a four-stage mechanical abrading on the samples. Roughness and water contact angles of all surfaces were then measured. The surface roughness factor and the solid fraction in contact with water by the Wenzel and Cassie-Baxter contact models were also calculated and compared with the corresponding measured contact angles to find out which regime was active. Results indicated that the surface microstructure and the type of constituents present at the surface influenced the cast iron surface wettability and that it was possible to change the surface contact angle by modification of the surface microstructure. The mechanically abraded gray cast iron followed the Wenzel-type regime while the electroetched surfaces of gray cast iron exhibited a transition from Wenzel to Cassie-Baxter type regime. In white cast iron, the results indicated Wenzel type behavior in the electroetched samples while for the mechanically abraded samples, none of these two models could predict the wetting behavior. Furthermore, the wetting angles of both gray and white cast irons were measured after 1, 2, 3 and 4 weeks of air exposure. The results showed that the wetting angles of both samples increased to above 90° after one week of air exposure which was likely due to adsorption of low surface energy hydrocarbons on the surfaces.
ToxCast Chemical Landscape: Paving the Road to 21st Century Toxicology.
Richard, Ann M; Judson, Richard S; Houck, Keith A; Grulke, Christopher M; Volarath, Patra; Thillainadarajah, Inthirany; Yang, Chihae; Rathman, James; Martin, Matthew T; Wambaugh, John F; Knudsen, Thomas B; Kancherla, Jayaram; Mansouri, Kamel; Patlewicz, Grace; Williams, Antony J; Little, Stephen B; Crofton, Kevin M; Thomas, Russell S
2016-08-15
The U.S. Environmental Protection Agency's (EPA) ToxCast program is testing a large library of Agency-relevant chemicals using in vitro high-throughput screening (HTS) approaches to support the development of improved toxicity prediction models. Launched in 2007, Phase I of the program screened 310 chemicals, mostly pesticides, across hundreds of ToxCast assay end points. In Phase II, the ToxCast library was expanded to 1878 chemicals, culminating in the public release of screening data at the end of 2013. Subsequent expansion in Phase III has resulted in more than 3800 chemicals actively undergoing ToxCast screening, 96% of which are also being screened in the multi-Agency Tox21 project. The chemical library unpinning these efforts plays a central role in defining the scope and potential application of ToxCast HTS results. The history of the phased construction of EPA's ToxCast library is reviewed, followed by a survey of the library contents from several different vantage points. CAS Registry Numbers are used to assess ToxCast library coverage of important toxicity, regulatory, and exposure inventories. Structure-based representations of ToxCast chemicals are then used to compute physicochemical properties, substructural features, and structural alerts for toxicity and biotransformation. Cheminformatics approaches using these varied representations are applied to defining the boundaries of HTS testability, evaluating chemical diversity, and comparing the ToxCast library to potential target application inventories, such as used in EPA's Endocrine Disruption Screening Program (EDSP). Through several examples, the ToxCast chemical library is demonstrated to provide comprehensive coverage of the knowledge domains and target inventories of potential interest to EPA. Furthermore, the varied representations and approaches presented here define local chemistry domains potentially worthy of further investigation (e.g., not currently covered in the testing library or defined by toxicity "alerts") to strategically support data mining and predictive toxicology modeling moving forward.
14 CFR 29.621 - Casting factors.
Code of Federal Regulations, 2011 CFR
2011-01-01
... established. (3) For castings procured to a specification that guarantees the mechanical properties of the material in the casting and provides for demonstration of these properties by test of coupons cut from the...
14 CFR 27.621 - Casting factors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... established. (3) For castings procured to a specification that guarantees the mechanical properties of the material in the casting and provides for demonstration of these properties by test of coupons cut from the...
14 CFR 29.621 - Casting factors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... established. (3) For castings procured to a specification that guarantees the mechanical properties of the material in the casting and provides for demonstration of these properties by test of coupons cut from the...
14 CFR 27.621 - Casting factors.
Code of Federal Regulations, 2011 CFR
2011-01-01
... established. (3) For castings procured to a specification that guarantees the mechanical properties of the material in the casting and provides for demonstration of these properties by test of coupons cut from the...
Viaro, Riccardo; Budri, Mirco; Parmiani, Pierantonio; Franchi, Gianfranco
2014-05-15
Experimental and clinical studies have attempted to evaluate the changes in cortical activity seen after immobilization-induced longterm sensorimotor restriction, although results remain controversial. We used intracortical microstimulation (ICMS), which provides topographic movement representations of the motor areas in both hemispheres with optimal spatial characterization, combined with behavioural testing to unravel the effects of limb immobilization on movement representations in the rat primary motor cortex (M1). Unilateral forelimb immobilization in rats was achieved by casting the entire limb and leaving the cast in place for 15 or 30 days. Changes in M1 were bilateral and specific for the forelimb area, but were stronger in the contralateral-to-cast hemisphere. The threshold current required to evoke forelimb movement increased progressively over the period in cast, whereas the forelimb area size decreased and the non-excitable area size increased. Casting resulted in a redistribution of proximal/distal movement representations: proximal forelimb representation increased, whereas distal representation decreased in size. ICMS after cast removal showed a reversal of changes, which remained partial at 15 days. Local application of the GABAA-antagonist bicuculline revealed the impairment of cortical synaptic connectivity in the forelimb area during the period of cast and for up to 15 days after cast removal. Six days of rehabilitation using a rotarod performance protocol after cast removal did not advance map size normalization in the contralateral-to-cast M1 and enabled the cortical output towards the distal forelimb only in sites that had maintained their excitability. These results are relevant to our understanding of adult M1 plasticity during and after sensorimotor deprivation, and to new approaches to conditions that require longterm limb immobilization. © 2014 The Authors. The Journal of Physiology © 2014 The Physiological Society.
de Aguiar, Fábio Afrânio; Tiossi, Rodrigo; Rodrigues, Renata Cristina Silveira; Mattos, Maria de Gloria Chiarello; Ribeiro, Ricardo Faria
2009-04-01
The aim of this study was to compare the accuracy of fit of three types of implant-supported frameworks cast in Ni-Cr alloy: specifically, a framework cast as one piece compared to frameworks cast separately in sections to the transverse or the diagonal axis, and later laser welded. Three sets of similar implant-supported frameworks were constructed. The first group of six 3-unit implant-supported frameworks were cast as one piece, the second group of six were sectioned in the transverse axis of the pontic region prior to casting, and the last group of six were sectioned in the diagonal axis of the pontic region prior to casting. The sectioned frameworks were positioned in the matrix (10 N.cm torque) and laser welded. To evaluate passive fit, readings were made with an optical microscope with both screws tightened and with only one-screw tightened. Data were submitted to ANOVA and Tukey-Kramer's test (p < 0.05). When both screws were tightened, no differences were found between the three groups (p > 0.05). In the single-screw-tightened test, with readings made opposite to the tightened side, the group cast as one piece (57.02 +/- 33.48 mum) was significantly different (p < 0.05) from the group sectioned diagonally (18.92 +/- 4.75 microm) but no different (p > 0.05) from the group transversally sectioned (31.42 +/- 20.68 microm). On the tightened side, no significant differences were found between the groups (p > 0.05). Results of this study showed that casting diagonally sectioned frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves the levels of passivity to the same frameworks when compared to structures cast as one piece.
Results of Casting in Severe Curves in Infantile Scoliosis.
Stasikelis, Peter J; Carpenter, Ashley M
2018-04-01
Previous work has demonstrated best results for casting in infantile scoliosis when the curves are small and the child begins casting under 2 years of age. This study examines if casting can delay the need for growth friendly instrumentation in severe curves (50 to 106 degrees) and how the comorbidities of syrinx or genetic syndromes affected outcomes. All children undergoing casting for scoliosis at a single institution over an 8-year period were examined. Inclusion criteria included initial curve at first casting of ≥50 degrees, age ≤3 years at the start of casting, and a minimum follow-up of 3 years. Of 148 children undergoing casting during this period, 44 met our inclusion criteria. All children underwent magnetic resonance imaging. Ten children with a syrinx were identified. Ten children had known genetic syndromes (2 who also had a syrinx). The 26 children without these comorbidities were considered idiopathic. Curve magnitude ranged from 50 to 106 degrees. Nine of the 26 (35%) children in the children with idiopathic curves demonstrated resolution of their curves, while only 3 of the remaining 18 (17%) did. Of the children that did not have resolution of their curves, 14 were maintained over the entire follow-up period to within 15 degrees of their initial curve and 13 were improved 15 degrees or more. Only 5 children had an increase of 15 degrees or more over the follow-up period and 4 of these have undergone growth friendly instrumentation after a mean delay from initial cast of 71 months (range, 18 to 100 mo). This study demonstrates that even in severe curves, casting was effective in delaying instrumentation in all cases, and led to curve resolution of the curves in 12 of 44 children. Level III-case control study.
MACHINING ELIMINATION THROUGH APPLICATION OF THREAD FORMING FASTENERS IN NET SHAPED CAST HOLES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cleaver, Ryan J; Cleaver, Todd H; Talbott, Richard
The ultimate objective of this work was to eliminate approximately 30% of the machining performed in typical automotive engine and transmission plants by using thread forming fasteners in as-cast holes of aluminum and magnesium cast components. The primary issues at the source of engineers reluctance to implementing thread forming fasteners in lightweight castings are: * Little proof of consistency of clamp load vs. input torque in either aluminum or magnesium castings. * No known data to understand the effect on consistency of clamp load as casting dies wear. The clamp load consistency concern is founded in the fact that amore » portion of the input torque used to create clamp load is also used to create threads. The torque used for thread forming may not be consistent due to variations in casting material, hole size and shape due to tooling wear and process variation (thermal and mechanical). There is little data available to understand the magnitude of this concern or to form the basis of potential solutions if the range of clamp load variation is very high (> +/- 30%). The range of variation that can be expected in as-cast hole size and shape over the full life cycle of a high pressure die casting die was established in previous work completed by Pacific Northwest National Laboratory, (PNNL). This established range of variation was captured in a set of 12 cast bosses by designing core pins at the size and draft angles identified in the sited previous work. The cast bosses were cut into nuts that could be used in the Ford Fastener Laboratory test-cell to measure clamp load when a thread forming fastener was driven into a cast nut. There were two sets of experiments run. First, a series of cast aluminum nuts were made reflecting the range of shape and size variations to be expected over the life cycle of a die casting die. Taptite thread forming fasteners, (a widely used thread forming fastener suitable for aluminum applications), were driven into the various cored, as-cast nuts at a constant input torque and resulting clamp loads were recorded continuously. The clamp load data was used to determine the range of clamp loads to be expected. The bolts were driven to failure. The clamp load corresponding to the target input of 18.5 Nm was recorded for each fastener. In a like fashion, a second set of experiments were run with cast magnesium nuts and ALtracs thread forming fasteners, (a widely used thread forming fastener suitable for magnesium applications). Again all clamp loads were recorded and analyzed similarly to the Taptites in aluminum cast nuts. Results from previous work performed on the same test cell for a Battelle project using standard M8 bolts into standard M8 nuts were included as a comparator for a standard bolt and nut application. The results for the thread forming fasteners in aluminum cast holes were well within industry expectations of +/- 30% for out of the box and robustness range testing. The results for the dry and lubed extreme conditions were only slightly higher than industry expectations at +/- 35.6%. However, when compared to the actual Battelle results (+/- 40%) for a standard bolt and nut the tread forming fasteners performed slightly better. The results for the thread forming fasteners in magnesium cast holes were all well within industry expectations of +/- 30% for all three conditions. The robustness range (.05mm larger and smaller holes than the expected wear pattern of a die casting die at full life cycle) results also fell within the industry expectations for standard threaded fasteners. These results were very encouraging. It was concluded that this work showed that clamp load variation with thread forming fasteners is consistent with industry expectations for standard steel bolts and nuts at +/- 30%. There does not appear to be any significant increase in clamp load variation due to the application of thread forming fasteners in as-cast holes of aluminum or magnesium over the effective life of a die casting mold. The fully implemented potential benefit of thread forming fasteners in as-cast holes of aluminum and magnesium is estimated to be 6 trillion Btu per year for North America. Economic benefit is estimated to be nearly $800 million per year. Environmental benefits and quality improvements will also result from full implementation of this technology.« less
22 CFR 121.10 - Forgings, castings, and machined bodies.
Code of Federal Regulations, 2014 CFR
2014-04-01
... STATES MUNITIONS LIST Enumeration of Articles § 121.10 Forgings, castings, and machined bodies. The U.S. Munitions List controls as defense articles those forgings, castings, and other unfinished products, such as...
Modeling and simulation of clutch pressure plate casting using alternate materials
NASA Astrophysics Data System (ADS)
Madhuraj, H. N.; Bharath, M. R.
2018-04-01
Clutch Pressure Plate is a stress bearing component in the clutch assembly. Cast iron alloys like FG300, G2500 are commonly used for clutch pressure plate castings. These materials have high compressive strength, low tensile strength & no ductility but these cost high for the manufacturers. There is a need for alternate material so as to reduce cost, defects in castings without losing the life and effectiveness of the clutch plate. The work carried out here is modeling the clutch pressure plate using CAD tool. And then the casting process is simulated by casting simulation for fluid flow and solidification analysis by trying alternate material. Here the castability of the alternate material En-Gjs-400-15 and the commonly used material FG300 for the clutch pressure plate component is analyzed by designing and optimizing a proper gating system.
Strip casting with fluxing agent applied to casting roll
Williams, R.S.; O`Malley, R.J.; Sussman, R.C.
1997-07-29
A strip caster for producing a continuous strip includes a tundish for containing a melt, a pair of horizontally disposed water cooled casting rolls and devices for electrostatically coating the outer peripheral chill surfaces of the casting rolls with a powder flux material. The casting rolls are juxtaposed relative to one another for forming a pouting basin for receiving the melt through a teeming tube thereby establishing a meniscus between the rolls for forming the strip. The melt is protected from the outside air by a non-oxidizing gas passed through a supply line to a sealing chamber. A preferred flux is boron oxide having a melting point of about 550 C. The flux coating enhances wetting of the steel melt to the casting roll and dissolves any metal oxide formed on the roll. 3 figs.
Sweet, Laurene A; OʼNeill, Lindsey M; Dobbs, Matthew B
2014-01-01
The purpose of this report is to explore assessment and serial casting intervention for painful rigid flatfoot deformities with vertical talus in an adolescent girl with hereditary spastic paraplegia who was nonambulatory. The participant's right foot underwent 2 phases of casting with correction first toward hindfoot inversion and then dorsiflexion. Because of a vertical talus, her left foot required an intermediate casting toward plantar flexion, inversion, and forefoot adduction prior to casting toward dorsiflexion. The patient improved despite the underlying progressive neuromuscular disorder. Pain ameliorated and she returned to supported standing and transfers. Spasticity decreased bilaterally and the flexibility of her foot deformities improved to allow orthotic fabrication in subtalar neutral. Results were maintained at 12 and 16 months. Individualized multiphase serial casting requires further investigation with patients such as those with hereditary spastic paraplegia.
Vacuum investment cast PH13-8Mo corrosion resistant steel. (SAE standard)
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1991-07-01
An industry-wide interest has arisen with regards to the properties and capabilities of investment cast PH 13-8Mo corrosion resistant steel. Specifically of interest are the structural applications in the aerospace industry for this product heat treated to the H1000 condition. The objective of this AMEC cooperative test program was to generate and compile useful data for aerospace structural evaluation of investment cast PH 13-8Mo heat treated to H1000. The determination was made of overall mechanical properties, fatigue, fracture toughness, and crack growth data along with basic microstructural evaluation of the investment cast material. The evaluation of mechanical property variations betweenmore » cast and machined tensile specimens and evaluation of microstructural constituents. PH 13-8Mo, H1000 investment castings for use in the aerospace industry is included.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sengupta, S.; Soda, H.; McLean, A.
2000-01-01
A ternary eutectic alloy with a composition of 57.2 pct Bi, 24.8 pct In, and 18 pct Sn was continuously cast into wire of 2 mm diameter with casting speeds of 14 and 79 mm/min using the Ohno Continuous Casting (OCC) process. The microstructures obtained were compared with those of statically cast specimens. Extensive segregation of massive Bi blocks, Bi complex structures, and tin-rich dendrites was found in specimens that were statically cast. Decomposition of {radical}Sn by a eutectoid reaction was confirmed based on microstructural evidence. Ternary eutectic alloy with a cooling rate of approximately 1 C/min formed a doublemore » binary eutectic. The double binary eutectic consisted of regions of BiIn and decomposed {radical}Sn in the form of a dendrite cell structure and regions of Bi and decomposed {radical}Sn in the form of a complex-regular cell. The Bi complex-regular cells, which are a ternary eutectic constituent, existed either along the boundaries of the BiIn-decomposed {radical}Sn dendrite cells or at the front of elongated dendrite cell structures. In the continuously cast wires, primary Sn dendrites coupled with a small Bi phase were uniformly distributed within the Bi-In alloy matrix. Neither massive Bi phase, Bi complex-regular cells, no BiIn eutectic dendrite cells were observed, resulting in a more uniform microstructure in contrast to the heavily segregated structures of the statically cast specimens.« less
Role of chicken astrovirus as a causative agent of gout in commercial broilers in India.
Bulbule, N R; Mandakhalikar, K D; Kapgate, S S; Deshmukh, V V; Schat, K A; Chawak, M M
2013-01-01
Several outbreaks of gout were reported in commercial broilers in India during 2011 and 2012, causing up to 40% mortality in the birds. Gross and histopathological observations confirmed gout. Quantitative reverse transcriptase polymerase chain reaction (qRT-PCR) analysis from kidney samples of gout-affected birds indicated the presence of chicken astrovirus (CAstV) in 41.7% of cases and a mixed infection of CAstV and avian nephritis virus (ANV) in 36.4% of cases. CAstV isolated from gout-affected kidneys by inoculating embryonated specific pathogen free (SPF) eggs showed dwarfing in embryos and a cytopathic effect in chicken embryo kidney cells. Inoculation of 1-day-old SPF and broiler chicks with CAstVs caused gout and mortality between 4 and 10 days post inoculation. Virus isolation and qRT-PCR analysis showed the presence of only CAstV in inoculated chicks. Sequence analysis of capsid genes indicated a major group of Indian CAstVs that displayed 92.0 to 99.2% intergroup amino acid identity and 83.9 to 90.4% identity with subgroup Bi CAstVs of UK origin. We designated this group Indian Bi. Analysis of the partial polymerase amino acid sequences of our isolates indicated two groups of CAstVs (Indian 1 and 2) that displayed 90.2 to 95.5% amino acid identity between them. We thus report for the first time that, in addition to infectious bronchitis virus and ANV, CAstVs are a causative agent of gout.
Freeze Tape Cast Thick Mo Doped Li 4Ti 5O 12 Electrodes for Lithium-Ion Batteries
Ghadkolai, Milad Azami; Creager, Stephen; Nanda, Jagjit; ...
2017-08-30
Lithium titanate (Li 4Ti 5O 12) powders with and without molybdenum doping (LTO and MoLTO respectively) were synthesized by a solid-state method and used to fabricate electrodes on Cu foil using a normal tape-cast method and a novel freeze-tape-cast method. Modest molybdenum doping produces a significant electronic conductivity increase (e.g. 1 mS cm -1 for MoLTO vs 10 -7 mS cm -1 for LTO) that is thought to reflect a partial Ti 4+ reduction to Ti 3+ with charge compensation by the Mo 6+ dopant, producing a stable mixed-valent Ti 4+/3+ state. Freeze-tape-cast electrodes were fabricated by a variant ofmore » the normal tape-cast method that includes a rapid freezing step in which the solvent in the Cu-foil-supported slurry is rapidly frozen on a cold finger then subsequently sublimed to create unidirectional columnar macropores in the electrode. The resulting electrodes exhibit high porosity and low tortuosity which enhances electrolyte accessibility throughout the full electrode thickness. Freeze-tape-cast electrodes subjected to galvanostatic charge-discharge testing as cathodes in cells vs. a lithium metal anode exhibit higher specific capacity and lower capacity loss at high discharge rates compared with normal-tape-cast electrodes of the same mass loading, despite the fact that the freeze-tape-cast electrodes are nearly twice as thick as the normal tape cast electrodes.« less
Fu, Xiaoming; Peng, Chun; Li, Zan; Liu, Shan; Tan, Minmin; Song, Jinlin
2017-01-01
To explore a new technique for reconstructing and measuring three-dimensional (3D) models of orthodontic plaster casts using multi-baseline digital close-range photogrammetry (MBDCRP) with a single-lens reflex camera. Thirty sets of orthodontic plaster casts that do not exhibit severe horizontal overlap (>2 mm) between any two teeth were recorded by a single-lens reflex camera with 72 pictures taken in different directions. The 3D models of these casts were reconstructed and measured using the open source software MeshLab. These parameters, including mesio-distal crown diameter, arch width, and arch perimeter, were recorded six times on both the 3D digital models and on plaster casts by two examiners. Statistical analysis was carried out using the Bland-Altman method to measure agreement between the novel method and the traditional calliper method by calculating the differences between mean values. The average differences between the measurements of the photogrammetric 3D models and the plaster casts were 0.011-0.402mm. The mean differences between measurements obtained by the photogrammetric 3D models and the dental casts were not significant except for the lower arch perimeter (P>0.05), and all the differences were regarded as clinically acceptable (<0.5 mm). Measurements obtained by MBDCRP are compared well with those obtained from plaster casts, indicating that MBDCRP is an alternate way to store and measure dental plaster casts without severe horizontal overlap between any two teeth.
Structural and compositional analysis of a casting mold sherd from ancient China.
Zong, Yunbing; Yao, Shengkun; Lang, Jianfeng; Chen, Xuexiang; Fan, Jiadong; Sun, Zhibin; Duan, Xiulan; Li, Nannan; Fang, Hui; Zhou, Guangzhao; Xiao, Tiqiao; Li, Aiguo; Jiang, Huaidong
2017-01-01
Casting had symbolic significance and was strictly controlled in the Shang dynasty of ancient China. Vessel casting was mainly distributed around the Shang capital, Yin Ruins, which indicates a rigorous centralization of authority. Thus, for a casting mold to be excavated far from the capital region is rare. In addition to some bronze vessel molds excavated at the Buyao Village site, another key discovery of a bronze vessel mold occurred at Daxinzhuang. The Daxinzhuang site was a core area in the east of Shang state and is an important site to study the eastward expansion of the Shang. Here, combining synchrotron X-rays and other physicochemical analysis methods, nondestructive three-dimensional structure imaging and different elemental analyses were conducted on this mold sherd. Through high penetration X-ray tomography, we obtained insights on the internal structure and discovered some pores. We infer that the generation of pores inside the casting mold sherd was used to enhance air permeability during casting. Furthermore, we suppose that the decorative patterns on the surface were carved and not pasted onto it. Considering the previous compositional studies of bronze vessels, the copper and iron elements were analyzed by different methods. Unexpectedly, a larger amount of iron than of copper was detected on the surface. According to the data analysis and archaeological context, the source of iron on the casting mold sherd could be attributed to local soil contamination. A refined compositional analysis confirms that this casting mold was fabricated locally and used for bronze casting.