Yon, Calantha K; Low, Chai L
2013-01-15
The effects of heparin versus sodium citrate 4% as a lock solution on catheter-related infections (CRIs), catheter patency, and hospitalizations in long-term hemodialysis patients with central venous catheters (CVCs) were compared. Data for patients receiving heparin lock solutions were collected from July 2008 to July 2009. Data on patients receiving sodium citrate 4% lock solution were collected from September 2009 through December 2010. Patients who were receiving the heparin lock solution who continued to have a CVC in September 2009 were transitioned from heparin to sodium citrate catheter 4% lock solution. New patients with CVCs placed after September 2009 received sodium citrate 4% without a period of using heparin lock solution. Pertinent information on patient medical history, bleeding or clotting events, infections, and hospitalization was collected. Data were collected retrospectively for the heparin group and prospectively for the sodium citrate group. Data were collected from 360 patient-months among 60 patients during the heparin treatment period and from 451 patient-months among 58 patients during the sodium citrate period. Thirty-three patients were common to both study groups. There were significantly more CRIs and CRIs per 1000 catheter-days in the heparin than the sodium citrate treatment group. Secondary outcomes of hospitalizations and catheter thrombosis were comparable. CRIs and thrombosis led to significantly more catheter exchanges or removals in the heparin group than the sodium citrate group. In patients with long-term hemodialysis catheters, a lock solution of sodium citrate 4% was associated with fewer CRIs and similar effectiveness when compared with heparin 5000 units/mL.
Moore, Harold L; Twardowski, Zbylut J
2003-10-01
Soft, cuffed indwelling catheters are used for hemodialysis access and intravenous infusions. The majority of these catheters are removed as a result of infection caused by contamination of the catheter hub during the connection/disconnection procedures. To prevent clot formation in the lumen, these catheters are routinely "locked" with heparin or some other anticoagulant. None of the anticoagulants commonly used as locking solutions demonstrates any significant bactericidal properties. The primary goal of this study was the development of a catheter locking method that retains anticoagulant properties at the catheter tip and bactericidal properties at the catheter hub. The second goal was to find a solution that possesses excellent bactericidal properties but is not detrimental in the event of injection into the patient's blood stream. The bactericidal properties of acidified, concentrated saline (ACS) were compared to concentrated trisodium citrate and to commonly used bactericidal agents such as povidone iodine, sodium hypochlorite, and chlorhexidine. In preliminary studies, the rate of diffusion of solutes was measured in glass tubes. In another set of experiments, the mixing of two solutions (anticoagulant and bactericide) separated by an air bubble ("air-bubble method") was observed in stationary and moving systems. The final series of studies compared the bactericidal properties of ACS to other bactericidal solutions mentioned above. The solutions diffused swiftly in the glass tubes, and by the third day, both solutions were mixed. The air-bubble method prevented mixing in both stationary and moving systems. The bactericidal properties of ACS were superior to all other tested solutions. The proposed method of catheter locking with anticoagulant at the catheter tip and ACS at the catheter hub separated by an air bubble is a promising technique and clinical studies are warranted.
Shenep, L E; Shenep, M A; Cheatham, W; Hoffman, J M; Hale, A; Williams, B F; Perkins, R; Hewitt, C B; Hayden, R T; Shenep, J L
2011-12-01
There is little published evidence regarding whether heparin lock solutions containing preservatives prevent catheter-related infections. However, adverse effects from preservative-containing flushes have been documented in neonates, leading many hospitals to avoid their use altogether. Infection control records from 1982 to 2008 at St. Jude Children's Research Hospital (SJCRH) were reviewed regarding the incidence of catheter-related infections and the use of preservative-containing intravenous locks. In addition, the antimicrobial activities of heparin lock solution containing the preservatives parabens (0.165%) or benzyl alcohol (0.9%), and 70% ethanol were examined against Staphylococcus epidermidis, Staphylococcus aureus, Escherichia coli, Bacillus cereus, Pseudomonas aeruginosa and Candida albicans, and compared with preservative-free saline with and without heparin. Growth was assessed after exposure to test solutions for 0, 2, 4 and 24h at 35 °C. The activities of preservatives were assessed against both planktonic (free-floating) and sessile (biofilm-embedded) micro-organisms using the MBEC Assay. Infection control records revealed two periods of increased catheter-related infections, corresponding with two intervals when preservative-free heparin was used at SJCRH. Heparin solution containing preservatives demonstrated significant antimicrobial activity against both planktonic and sessile forms of all six microbial species. Ethanol demonstrated the greatest antimicrobial activity, especially following short incubation periods. Heparin lock solutions containing the preservatives parabens or benzyl alcohol, and 70% ethanol demonstrated significant antimicrobial activity against both planktonic and sessile micro-organisms commonly responsible for catheter-related infections. These findings, together with the authors' historical infection control experience, support the use of preservatives in intravenous lock solutions to reduce catheter related infections in patients beyond the neonatal period. Copyright © 2011 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Luther, Megan K; Mermel, Leonard A; LaPlante, Kerry L
2016-03-01
Results of a study of the activity of antibiotic lock solutions of vancomycin and telavancin against biofilm-forming strains of Staphylococcus epidermidis, Enterococcus faecalis, and Staphylococcus aureus are reported. An established in vitro central venous catheter model was used to evaluate lock solutions containing vancomycin (5 mg/mL) or telavancin (5 mg/mL), with and without preservative-containing heparin sodium (with 0.45% benzyl alcohol) 2500 units/mL, heparin, and 0.9% sodium chloride solution. Lock solutions were introduced after 24-hour bacterial growth in catheters incubated at 35 °C. After 72 hours of exposure to the lock solutions, catheters were drained, flushed, and cut into segments for quantification of colony-forming units. Against S. epidermidis, vancomycin and telavancin (with or without heparin) had similar activity. Against E. faecalis, vancomycin alone was more active than telavancin alone (p < 0.01). Against S. aureus, vancomycin plus heparin had activity similar to that of vancomycin alone; both lock agents had greater activity than telavancin (p < 0.02). The addition of heparin was associated with reduced activity of the vancomycin lock solution against S. epidermidis and E. faecalis (p < 0.01). Telavancin activity was not significantly changed with the addition of heparin. In a central venous catheter model, vancomycin and telavancin activity was similar in reducing biofilm-producing S. epidermidis. However, vancomycin was more active than telavancin against E. faecalis and S. aureus. None of the tested agents eradicated biofilm-forming strains. The addition of preservative-containing heparin sodium 2500 units/mL to vancomycin was associated with reduced activity against S. epidermidis and E. faecalis. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Chaftari, Anne-Marie; Hachem, Ray; Szvalb, Ariel; Taremi, Mahnaz; Granwehr, Bruno; Viola, George Michael; Sapna, Amin; Assaf, Andrew; Numan, Yazan; Shah, Pankil; Gasitashvili, Ketevan; Natividad, Elizabeth; Jiang, Ying; Slack, Rebecca; Reitzel, Ruth; Rosenblatt, Joel; Mouhayar, Elie; Raad, Issam
2017-07-01
For long-term central lines (CL), the lumen is the major source of central line-associated bloodstream infections (CLABSI). The current standard of care for maintaining catheter patency includes flushing the CL with saline or heparin. Neither agent has any antimicrobial activity. Furthermore, heparin may enhance staphylococcal biofilm formation. We evaluated the safety and efficacy of a novel nonantibiotic catheter lock solution for the prevention of CLABSI. Between November 2015 and February 2016, we enrolled 60 patients with hematologic malignancies who had peripherally inserted central catheters (PICC) to receive the study lock solution. The study lock consisted of 15 or 30 μg/ml of nitroglycerin in combination with 4% sodium citrate and 22% ethanol. Each lumen was locked for at least 2 h once daily prior to being flushed. After enrollment of 10 patients at the lower nitroglycerin dose without evidence of toxicity, the dose was escalated to the higher dose (30 μg/ml). There were no serious related adverse events or episodes of hypotension with lock administration. Two patients experienced mild transient adverse events (one headache and one rash) possibly related to the lock and that resolved without residual effect. The CLABSI rate was 0 on lock days versus 1.6/1,000 catheter days (CD) off lock prophylaxis, compared with a rate of 1.9/1,000 CD at the institution in the same patient population. In conclusion, the nitroglycerin-based lock prophylaxis is safe and well tolerated. It may prevent CLABSI when given daily to cancer patients. Large, prospective, randomized clinical trials are needed to validate these findings. (This study has been registered at ClinicalTrials.gov under identifier NCT02577718.). Copyright © 2017 American Society for Microbiology.
Hachem, Ray; Szvalb, Ariel; Taremi, Mahnaz; Granwehr, Bruno; Viola, George Michael; Sapna, Amin; Assaf, Andrew; Numan, Yazan; Shah, Pankil; Gasitashvili, Ketevan; Natividad, Elizabeth; Jiang, Ying; Slack, Rebecca; Reitzel, Ruth; Rosenblatt, Joel; Mouhayar, Elie; Raad, Issam
2017-01-01
ABSTRACT For long-term central lines (CL), the lumen is the major source of central line-associated bloodstream infections (CLABSI). The current standard of care for maintaining catheter patency includes flushing the CL with saline or heparin. Neither agent has any antimicrobial activity. Furthermore, heparin may enhance staphylococcal biofilm formation. We evaluated the safety and efficacy of a novel nonantibiotic catheter lock solution for the prevention of CLABSI. Between November 2015 and February 2016, we enrolled 60 patients with hematologic malignancies who had peripherally inserted central catheters (PICC) to receive the study lock solution. The study lock consisted of 15 or 30 μg/ml of nitroglycerin in combination with 4% sodium citrate and 22% ethanol. Each lumen was locked for at least 2 h once daily prior to being flushed. After enrollment of 10 patients at the lower nitroglycerin dose without evidence of toxicity, the dose was escalated to the higher dose (30 μg/ml). There were no serious related adverse events or episodes of hypotension with lock administration. Two patients experienced mild transient adverse events (one headache and one rash) possibly related to the lock and that resolved without residual effect. The CLABSI rate was 0 on lock days versus 1.6/1,000 catheter days (CD) off lock prophylaxis, compared with a rate of 1.9/1,000 CD at the institution in the same patient population. In conclusion, the nitroglycerin-based lock prophylaxis is safe and well tolerated. It may prevent CLABSI when given daily to cancer patients. Large, prospective, randomized clinical trials are needed to validate these findings. (This study has been registered at ClinicalTrials.gov under identifier NCT02577718.) PMID:28416559
Adverse effects associated with ethanol catheter lock solutions: a systematic review.
Mermel, Leonard A; Alang, Neha
2014-10-01
Antimicrobial lock therapy has been widely utilized internationally for the prevention and management of intravascular catheter-related bloodstream infections. One of the agents commonly utilized for lock therapy is ethanol. However, a systematic review of adverse events associated with ethanol locks has not been published. PubMed was searched to collect articles published from May 2003 through March 2014. The bibliographies of relevant articles were also reviewed. In vitro studies of the mechanical properties of catheters after ethanol immersion have revealed changes predominantly in polyurethane catheters and to a lesser extent in silicone and Carbothane catheters. An elution of polymers from polyurethane and Carbothane catheters has been observed at the ethanol concentrations used in ethanol lock therapy. Ethanol above a concentration of 28% leads to plasma protein precipitation. Ethanol locks were associated with catheter occlusion in 11 studies and independently increased the risk of thrombosis compared with heparin lock in a randomized trial. Six studies noted abnormalities in catheter integrity, including one case leading to catheter embolization. Of note, five of these studies involved silicone catheters. Ethanol lock use was associated with systemic side effects in 10 studies and possible side effects in one additional study. Four studies noted liver function test abnormalities, predominantly transaminase elevation, related to ethanol lock use. However, a prospective study did not find any difference in the risk of doubling the transaminase level above the normal range during use of ethanol locks compared with not using an ethanol lock. The use of ethanol locks has been associated with structural changes in catheters, as well as the elution of molecules from the catheter polymers. Clinical studies have revealed systemic toxicity, increased catheter occlusion and breaches in catheter integrity. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Kowalewska, Paulina M.; Petrik, Shawn M.; Di Fiore, Attilio E.; Fox-Robichaud, Alison E.
2018-01-01
Vascular catheters are a major cause of nosocomial bloodstream infections. ChloraLock (ATTWILL Medical Solutions, Inc, West Jordan, UT, and ICU Medical, Inc, San Clemente, CA) is a novel antimicrobial device containing chlorhexidine digluconate (CHG) that is fitted onto a syringe and infuses CHG into the catheter lumen during locking. The objective of this study was to evaluate the antimicrobial efficacy of ChloraLock with in vitro tests and its ability to reduce Staphylococcus aureus contamination of catheters in the external jugular veins of Yorkshire swine. ChloraLock significantly reduced the bacterial load in the in vitro tests by up to 6 log10 colony-forming units (CFU) and by 3 to 4 log10 CFU/lumen in vivo in a swine model with 0.9% NaCl catheter locks. PMID:29489705
Kowalewska, Paulina M; Petrik, Shawn M; Di Fiore, Attilio E; Fox-Robichaud, Alison E
Vascular catheters are a major cause of nosocomial bloodstream infections. ChloraLock (ATTWILL Medical Solutions, Inc, West Jordan, UT, and ICU Medical, Inc, San Clemente, CA) is a novel antimicrobial device containing chlorhexidine digluconate (CHG) that is fitted onto a syringe and infuses CHG into the catheter lumen during locking. The objective of this study was to evaluate the antimicrobial efficacy of ChloraLock with in vitro tests and its ability to reduce Staphylococcus aureus contamination of catheters in the external jugular veins of Yorkshire swine. ChloraLock significantly reduced the bacterial load in the in vitro tests by up to 6 log10 colony-forming units (CFU) and by 3 to 4 log10 CFU/lumen in vivo in a swine model with 0.9% NaCl catheter locks.
Shenep, L.E.; Shenep, M.A.; Cheatham, W.; Hoffman, J.M.; Hale, A.; Williams, B.F.; Perkins, R.; Hewitt, C.B.; Hayden, R.T.; Shenep, J. L.
2016-01-01
SUMMARY There is little published evidence regarding whether heparin lock solutions containing preservatives prevent catheter-related infections. However, adverse effects from preservative-containing flushes have been documented in neonates, leading many hospitals to avoid their use altogether. Infection control records from 1982 to 2008 at St. Jude Children’s Research Hospital (SJCRH) were reviewed regarding the incidence of CRIs and the use of preservative-containing intravenous locks. In addition, the antimicrobial activities of heparin lock solution containing the preservatives parabens (0.165%) or benzyl alcohol (0.9%), and 70% ethanol were examined against Staphylococcus epidermidis, Staphylococcus aureus, Escherichia coli, Bacillus cereus, Pseudomonas aeruginosa and Candida albicans, and compared with preservative-free saline with and without heparin. Growth was assessed after exposure to test solutions for 0, 2, 4 and 24 h at 35°C. The activities of preservatives were assessed against both planktonic (free-floating) and sessile (biofilm-embedded) micro-organisms using the MBEC Assay. Infection control records revealed two periods of increased catheter-related infections, corresponding with two intervals when preservative-free heparin was used at SJCRH. Heparin solution containing preservatives demonstrated significant antimicrobial activity against both planktonic and sessile forms of all six microbial species. Ethanol demonstrated the greatest antimicrobial activity, especially following short incubation periods. Heparin lock solutions containing the preservatives parabens or benzyl alcohol, and 70% ethanol demonstrated significant antimicrobial activity against both planktonic and sessile micro-organisms commonly responsible for CRIs. These findings, together with the authors’ historical infection control experience, support the use of preservatives in intravenous lock solutions to reduce catheter related infections in patients beyond the neonatal period. PMID:21945067
Norris, LeAnn B; Kablaoui, Farah; Brilhart, Maggie K; Bookstaver, P Brandon
2017-09-01
Central venous catheter (CVC) use is commonplace in cancer patients. Antimicrobial lock therapy (ALT), the instillation of a concentrated antimicrobial solution into the catheter lumen, is one method for preventing infection among CVCs. This systematic review discusses the effectiveness and safety of prophylactic ALT in cancer patients with CVCs. A literature search was performed using the Medline database and Google Scholar from inception until April 2016. The following terms were used: 'antimicrobial lock solution', 'antibiotic lock solution', 'oncology', 'hematology', 'pediatrics', 'prevention', 'cancer', 'catheter related bloodstream infections', 'central-line associated bloodstream infection' (CLABSI) and 'central venous catheter'. Studies evaluating prophylactic ALT in cancer patients alone were eligible for inclusion. Case reports, case series and in-vitro studies were excluded. In total, 78 articles were identified. Following all exclusions, 13 articles (three adult and 10 pediatric) were selected for evaluation. The most common agents utilized were vancomycin with heparin; ethanol; taurolidine; and minocycline with EDTA. Quality of evidence was moderate to high in adult studies and low to moderate in pediatric studies. Use of ALT decreased the incidence of CLABSI in the majority of studies; however, there were significant differences in definitions of CVC-related infection, dwell times and lock solutions. Lock therapy may be an adjunct in high-risk cancer patients for the prevention of CLABSI; higher quality evidence is needed for specific ALT recommendations. Copyright © 2017 Elsevier B.V. and International Society of Chemotherapy. All rights reserved.
Chaftari, Anne-Marie; Zakhour, Ramia; Jordan, Mary; Al Hamal, Zanaib; Jiang, Ying; Yousif, Ammar; Garoge, Kumait; Mulanovich, Victor; Viola, George M.; Kanj, Soha; Pravinkumar, Egbert; Rosenblatt, Joel; Hachem, Ray
2016-01-01
In cancer patients with long-term central venous catheters (CVC), removal and reinsertion of a new CVC at a different site might be difficult because of the unavailability of accessible vascular sites. In vitro and animal studies showed that a minocycline-EDTA-ethanol (M-EDTA-EtOH) lock solution may eradicate microbial organisms in biofilms, hence enabling the treatment of central line-associated bloodstream infections (CLABSI) while retaining the catheter in situ. Between April 2013 and July 2014, we enrolled 30 patients with CLABSI in a prospective study and compared them to a historical group of 60 patients with CLABSI who had their CVC removed and a new CVC inserted. Each catheter lumen was locked with an M-EDTA-EtOH solution for 2 h administered once daily, for a total of 7 doses. Patients who received locks had clinical characteristics that were comparable to those of the control group. The times to fever resolution and microbiological eradication were similar in the two groups. Patients with the lock intervention received a shorter duration of systemic antibiotic therapy than that of the control patients (median, 11 days versus 16 days, respectively; P < 0.0001), and they were able to retain their CVCs for a median of 74 days after the onset of bacteremia. The M-EDTA-EtOH lock was associated with a significantly decreased rate of mechanical and infectious complications compared to that of the CVC removal/reinsertion group, who received a longer duration of systemic antimicrobial therapy. (This study has been registered at ClinicalTrials.gov under registration no. NCT01539343.) PMID:27001822
Correa Barcellos, Franklin; Pereira Nunes, Bruno; Jorge Valle, Luciana; Lopes, Thiago; Orlando, Bianca; Scherer, Cintia; Nunes, Marcia; Araújo Duarte, Gabriela; Böhlke, Maristela
2017-04-01
Central venous catheters (CVC) are the only option when hemodialysis is needed for patients without definitive vascular access. However, CVC is associated with complications, such as infection, thrombosis, and dysfunction, leading to higher mortality and expenditures. The aim of this study was to compare the effectiveness of 30 % trisodium citrate (TSC30 %) with heparin as CVC lock solutions in preventing catheter-related bloodstream infections (CRBSI) and dysfunction in hemodialysis patients. Randomized, double-blind controlled trial comparing the event-free survival of non-tunneled CVC locked with heparin or TSC30 % in adult hemodialysis patients. The study included 464 catheters, 233 in heparin group, and 231 in TSC30 % group. The CRBSI-free survival of TSC30 % group was significantly shorter than that of heparin group. When stratified by insertion site, heparin was better than TSC30 % only in subclavian CVC. The dysfunction-free survival was not different between groups in the main analysis, but there is also a shorter survival among subclavian CVC locked with TSC30 % in stratified analysis. There was no difference on CRBSI-free or dysfunction-free survival between jugular vein CVC locked with heparin or 30 % citrate. However, subclavian CVC locked with 30 % citrate presented shorter event-free survival. This difference may be related to anatomical and positional effects, CVC design, and hydraulic aspects of the lock solution. CLINICALTRIALS. NCT02563041.
Can dalbavancin be used as a catheter lock solution?
Díaz-Ruíz, Cristina; Alonso, Beatriz; Cercenado, Emilia; Cruces, Raquel; Bouza, Emilio; Muñoz, Patricia; Guembe, María
2018-05-17
The new lipoglycopeptide dalbavancin has only been approved for acute bacterial skin and skin structure infections. However, its alternative use as a catheter lock solution could facilitate the conservative management of catheter-related bloodstream infection. Our objective was to assess the stability and activity of dalbavancin alone and in combination with heparin against methicillin-resistant Staphylococcus aureus (MRSA) and methicillin-resistant Staphylococcus epidermidis (MRSE) biofilms. We also compared the results with those obtained with vancomycin alone and in combination with heparin. We used a 96-well plate in vitro model based on 24 h biofilms of MRSA and MRSE (ATCC 43300, ATCC 35984 and one clinical strain of each). The biofilms were exposed to dalbavancin (0.128 mg ml -1 ) and vancomycin (5 mg ml -1 ) alone and in combination with heparin (60 IU). The median percentage reductions in metabolic activity, biomass, bacterial load, and cell viability for each solution were compared. Dalbavancin combined with heparin significantly reduced the median [interquartile range (IQR)] percentage of metabolic activity in MRSA biofilms compared with vancomycin [90.0 % (70.4-92.9 %) versus 35.0 % (14.8-59.6 %), P=0.006]. For the remaining variables studied, the combination was not inferior to vancomycin for MRSA and MRSE. Dalbavancin proved to be active against MRSA and MRSE biofilms. The combination of dalbavancin with heparin is a promising catheter lock solution that has the advantage of locking the catheter at home for 7 days.
Fontseré, Néstor; Cardozo, Celia; Donate, Javier; Soriano, Alex; Muros, Mercedes; Pons, Mercedes; Mensa, Josep; Campistol, Josep M; Navarro-González, Juan F; Maduell, Francisco
2014-07-01
Mortality and morbidity are significantly higher among patients with dialysis catheters, which has been associated with chronic activation of the immune system. We hypothesized that bacteria colonizing the catheter lumen trigger an inflammatory response. We aimed to evaluate the inflammatory profile of hemodialysis patients before and after locking catheters with an antimicrobial lock solution. High-sensitivity C-reactive protein (hs-CRP), interleukin-6 (IL-6), IL-10, and tumor necrosis factor alpha (TNF-α) were measured in serum, and levels of mRNA gene expression of IL-6, IL-10, and TNF-α were analyzed in peripheral blood mononuclear cells (PBMC). Samples were obtained at baseline and again after 3 months' use of taurolidine-citrate-heparin lock solution (TCHLS) in 31 hemodialysis patients. The rate of catheter-related bloodstream infections (CRBSI) was 1.08 per 1,000 catheter-days in the heparin period and 0.04 in the TCHLS period (P = 0.023). Compared with the baseline data, serum levels of hs-CRP and IL-6 showed median percent reductions of 18.1% and 25.2%, respectively (P < 0.01), without significant changes in TNF-α or IL-10 levels. Regarding cytokine gene expression in PBMC, the median mRNA expression levels of TNF-α and IL-6 decreased by 20% (P < 0.05) and 19.7% (P = 0.01), respectively, without changes in IL-10 expression levels. The use of TCHLS to maintain the catheter lumen sterility significantly reduces the incidence of CRBSI and improves the inflammatory profile in hemodialysis patients with tunneled catheters. Further studies are needed to evaluate the potential beneficial effects on clinical outcomes. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
Cardozo, Celia; Donate, Javier; Soriano, Alex; Muros, Mercedes; Pons, Mercedes; Mensa, Josep; Campistol, Josep M.; Navarro-González, Juan F.; Maduell, Francisco
2014-01-01
Mortality and morbidity are significantly higher among patients with dialysis catheters, which has been associated with chronic activation of the immune system. We hypothesized that bacteria colonizing the catheter lumen trigger an inflammatory response. We aimed to evaluate the inflammatory profile of hemodialysis patients before and after locking catheters with an antimicrobial lock solution. High-sensitivity C-reactive protein (hs-CRP), interleukin-6 (IL-6), IL-10, and tumor necrosis factor alpha (TNF-α) were measured in serum, and levels of mRNA gene expression of IL-6, IL-10, and TNF-α were analyzed in peripheral blood mononuclear cells (PBMC). Samples were obtained at baseline and again after 3 months' use of taurolidine-citrate-heparin lock solution (TCHLS) in 31 hemodialysis patients. The rate of catheter-related bloodstream infections (CRBSI) was 1.08 per 1,000 catheter-days in the heparin period and 0.04 in the TCHLS period (P = 0.023). Compared with the baseline data, serum levels of hs-CRP and IL-6 showed median percent reductions of 18.1% and 25.2%, respectively (P < 0.01), without significant changes in TNF-α or IL-10 levels. Regarding cytokine gene expression in PBMC, the median mRNA expression levels of TNF-α and IL-6 decreased by 20% (P < 0.05) and 19.7% (P = 0.01), respectively, without changes in IL-10 expression levels. The use of TCHLS to maintain the catheter lumen sterility significantly reduces the incidence of CRBSI and improves the inflammatory profile in hemodialysis patients with tunneled catheters. Further studies are needed to evaluate the potential beneficial effects on clinical outcomes. PMID:24820084
Sofroniadou, Sofia; Revela, Ioanna; Kouloubinis, Alexandros; Makriniotou, Ioanna; Zerbala, Sinodi; Smirloglou, Despina; Kalocheretis, Petros; Drouzas, Apostolos; Samonis, George; Iatrou, Christos
2017-10-01
Ethanol lock solution has been mainly administered in paediatric and home parenteral nutrition patients in order to prevent catheter related blood stream infections (CRBSI). Its utility in hemodialysis (HD) patients with non-tunneled-uncuffed catheter (NTC) has been poorly explored. We conducted a prospective randomized study in chronic HD patients requiring a newly inserted NTC-while awaiting for the maturation of an already established arteriovenous fistula (AVF) or arteriovenous graft (AVG) or tunneled-cuffed catheter insertion. Patients were randomized in two groups: Group A, where the lock solution was ethanol 70% + unfractionated heparin 2000 U/mL and group B, that received only unfractionated heparin 2000 U/mL. Primary end point was CRBSIs whereas exit site infections, thrombotic and bleeding episodes were the secondary end points. One hundred three HD patients were enrolled in the study (group A, n = 52; group B, n = 51). The median number of catheter days was 32 for group A (range: 23-39) and 34 (range: 27-40) for group B with no statistically significant difference between the two groups. Group A (ethanol + heparin) demonstrated 4/52 episodes (7.69%) of CRBSI whereas Group B (heparin) 11/51 episodes (21.57%) (P = 0.04). CRBSI rates per 1000 catheter days were 2.53/1000 catheter days for group A and 6.7/1000 catheter days for group B (P = 0.04). Mean cumulative infection-free catheter survival in the ethanol group did not differ significantly compared to the heparin group (log-rank test = 2.99, P = 0.08). Thrombotic episodes did not differ between the two groups. Locking of NTCs in HD patients with ethanol 70% + unfractionated heparin reduces CRBSI rates without increasing the thrombotic episodes. © 2017 International Society for Hemodialysis.
Raad, Issam; Hachem, Ray; Tcholakian, Robert K.; Sherertz, Robert
2002-01-01
To determine the efficacy of antibiotic catheter lock solution in preventing catheter-related infections, silicone catheters were tunneled and inserted into the jugular veins of 18 rabbits. The catheters were challenged with an intraluminal injection of 105 CFU of slime-producing Staphylococcus epidermidis in 0.1 ml of water. The catheters were maintained on heparin (100 IU/ml) flush for the first 3 days. On day 3, quantitative blood samples for culture were obtained from the catheters and ear veins, which documented catheter-related bacteremia, and the rabbits were randomized to have their catheters flushed as follows: five animals were continued on heparin (100 IU/ml), five animals received vancomycin (3 mg/ml) with heparin (100 IU/ml), and eight animals received 3 mg of minocycline per ml with 30 mg of EDTA per ml (M-EDTA). All animals were killed at day 7. Blood, catheters, jugular veins, and heart valves were cultured quantitatively. Animals maintained on heparin developed catheter-related colonization, bacteremia, septic phlebitis, and endocarditis. Vancomycin-heparin partially prevented catheter colonization, bacteremia, and phlebitis (P = 0.2). M-EDTA completely prevented catheter colonization, catheter-related bacteremia, and phlebitis in all of the animals (P < 0.01). Tricuspid endocarditis was equally prevented by vancomycin-heparin and M-EDTA (P ≤ 0.06). In conclusion, the M-EDTA catheter flush solution was highly efficacious in preventing catheter-related colonization, bacteremia, septic phlebitis, and endocarditis in rabbits. PMID:11796338
Restrepo, Daniel; Laconi, Nicholas S; Alcantar, Norma A; West, Leigh A; Buttice, Audrey L; Patel, Saumil; Kayton, Mark L
2015-03-01
Clinical reports of ethanol-lock use for the prevention of catheter-related bloodstream infections have been marked by the occurrence of serious catheter occlusions, particularly among children with mediports. We hypothesized that precipitate forms when ethanol mixes with heparin at the concentrations relevant for vascular access devices, but that the use of a combination of two alcohols, ethanol and isopropanol, would diminish heparin-related precipitation, while retaining anti-bacterial and anti-fungal effects. Heparin (0-100units/mL) was incubated in ethanol-water solutions (30%-70% vol/vol) or in an aqueous solution containing equal parts (35% and 35% vol/vol) of isopropanol and ethanol. Precipitation at temperatures from 4 to 40°C was measured in nephelometric turbidity units using a benchtop turbidimeter. Growth of Escherichia coli, Staphylococcus aureus, and Candida albicans colonies were measured following exposure to solutions of ethanol or isopropanol-ethanol. Groupwise comparisons were performed using analysis of variance with Bonferroni-corrected, post-hoc T-testing. Seventy percent ethanol and heparin exhibit dose-dependent precipitation that is pronounced and significant at the concentrations typically used in mediports (p<0.05). Precipitate is significantly reduced by use of a combined 35% isopropanol-35% ethanol solution rather than 70% ethanol (p<0.05), while maintaining the solution's anti-bacterial and anti-fungal properties. On the other hand, although ethanol solutions under 70% form less precipitate with heparin, such concentrations are also less effective at bacterial colony inhibition than solutions of either 70% ethanol or 35% isopropanol-35% ethanol (p<0.05). A combined 35% isopropanol-35% ethanol locking solution inhibits bacterial and fungal growth similarly to 70% ethanol, but results in less precipitate than 70% ethanol when exposed to heparin. Further study of a combined isopropanol-ethanol locking solution for the prevention of catheter-related bloodstream infections should focus on the determination as to whether such a locking solution may reduce the rate of precipitation-related catheter occlusion, and whether it may be administered with low systemic toxicity. Copyright © 2015 Elsevier Inc. All rights reserved.
Chauhan, Ashwini; Lebeaux, David; Ghigo, Jean-Marc
2012-01-01
Biofilms that develop on indwelling devices are a major concern in clinical settings. While removal of colonized devices remains the most frequent strategy for avoiding device-related complications, antibiotic lock therapy constitutes an adjunct therapy for catheter-related infection. However, currently used antibiotic lock solutions are not fully effective against biofilms, thus warranting a search for new antibiotic locks. Metal-binding chelators have emerged as potential adjuvants due to their dual anticoagulant/antibiofilm activities, but studies investigating their efficiency were mainly in vitro or else focused on their effects in prevention of infection. To assess the ability of such chelators to eradicate mature biofilms, we used an in vivo model of a totally implantable venous access port inserted in rats and colonized by either Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, or Pseudomonas aeruginosa. We demonstrate that use of tetrasodium EDTA (30 mg/ml) as a supplement to the gentamicin (5 mg/ml) antibiotic lock solution associated with systemic antibiotics completely eradicated Gram-positive and Gram-negative bacterial biofilms developed in totally implantable venous access ports. Gentamicin-EDTA lock was able to eliminate biofilms with a single instillation, thus reducing length of treatment. Moreover, we show that this combination was effective for immunosuppressed rats. Lastly, we demonstrate that a gentamicin-EDTA lock is able to eradicate the biofilm formed by a gentamicin-resistant strain of methicillin-resistant S. aureus. This in vivo study demonstrates the potential of EDTA as an efficient antibiotic adjuvant to eradicate catheter-associated biofilms of major bacterial pathogens and thus provides a promising new lock solution. PMID:23027191
Raad, Issam; Hanna, Hend; Dvorak, Tanya; Chaiban, Gassan; Hachem, Ray
2007-01-01
Antimicrobial lock solutions may be needed to salvage indwelling catheters in patients requiring continuous intravenous therapy. We determined the activity of minocycline, EDTA, and 25% ethanol, alone or in combination, against methicillin-resistant Staphylococcus aureus and Candida parapsilosis catheter-related bloodstream infection strains in two established models of biofilm colonization. Biofilm-colonized catheter segments from a modified Robbins device and a silicone disk biofilm colonization model were exposed to these antimicrobial agents for 15 or 60 min, respectively. After exposure, segments were sonicated and cultured. To determine regrowth after incubation at 37 degrees C, following the brief exposure to the antimicrobial agents, an equal number of segments were washed, reincubated for 24 h, and then sonicated and cultured. The triple combination of minocycline-EDTA (M-EDTA) in 25% ethanol was the only antimicrobial lock solution that completely eradicated S. aureus and C. parapsilosis in biofilm of all segments tested in the two models, and it completely prevented regrowth. In addition, M-EDTA in 25% ethanol was significantly more effective in rapidly eradicating the growth or regrowth of methicillin-resistant S. aureus and C. parapsilosis biofilm colonization in the two models than the other solutions--minocycline, EDTA, M-EDTA, 25% ethanol, and EDTA in ethanol. We conclude that M-EDTA in 25% ethanol is highly effective at rapidly eradicating S. aureus and C. parapsilosis embedded in biofilm adhering to catheter segments.
Reitzel, Ruth A.; Hirsh-Ginsberg, Cheryl; Murray, Kimberly; Chaftari, Anne-Marie; Hachem, Ray; Raad, Issam
2016-01-01
The rapid, broad-spectrum, biofilm-eradicating activity of the combination of 0.01% nitroglycerin, 7% citrate, and 20% ethanol and its potential as a nonantibiotic, antimicrobial catheter lock solution (ACLS) were previously reported. Here, a nitroglycerin-citrate-ethanol (NiCE) ACLS optimized for clinical assessment was developed by reducing the nitroglycerin and citrate concentrations and increasing the ethanol concentration. Biofilm-eradicating activity was sustained when the ethanol concentration was increased from 20 to 22% which fully compensated for reducing the citrate concentration from 7% to 4% as well as the nitroglycerin concentration from 0.01% to 0.0015% or 0.003%. The optimized formulations demonstrated complete and rapid (2 h) eradication of methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-intermediate Staphylococcus aureus (VISA), methicillin-resistant Staphylococcus epidermidis (MRSE), vancomycin-resistant enterococci (VRE), multidrug-resistant (MDR) Pseudomonas aeruginosa, MDR Klebsiella pneumoniae, MDR Enterobacter cloacae, MDR Acinetobacter baumannii, MDR Escherichia coli, MDR Stenotrophomonas maltophilia, Candida albicans, and Candida glabrata biofilms. The optimized NiCE lock solutions demonstrated anticoagulant activities comparable to those of heparin lock solutions. NiCE lock solution was significantly more effective than taurolidine-citrate-heparin lock solution in eradicating biofilms of Staphylococcus aureus and Candida glabrata. The optimized, nonantibiotic, heparin-free NiCE lock solution demonstrates rapid broad-spectrum biofilm eradication as well as effective anticoagulant activity, making NiCE a high-quality ACLS candidate for clinical assessment. PMID:27297475
Catheter-Related Bloodstream Infections in Patients on Emergent Hemodialysis.
Rojas-Moreno, Christian A; Spiegel, Daniel; Yalamanchili, Venkata; Kuo, Elizabeth; Quinones, Henry; Sreeramoju, Pranavi V; Luby, James P
2016-03-01
This study had 2 objectives: (1) to describe the epidemiology of catheter-related bloodstream infections (CRBSI) in patients with end-stage renal disease (ESRD) who have no access to scheduled dialysis and (2) to evaluate whether a positive culture of the heparin-lock solution is associated with subsequent development of bacteremia. Retrospective observational cohort design for objective 1; and prospective cohort design for objective 2. The study was conducted in a 770-bed public academic tertiary hospital in Dallas, Texas. The participants were patients with ESRD undergoing scheduled or emergent hemodialysis. We reviewed the records of 147 patients who received hemodialysis between January 2011 and May 2011 and evaluated the rate of CRBSI in the previous 5 years. For the prospective study, we cultured the catheter heparin-lock solution in 62 consecutive patients between June 2012 and August 2012 and evaluated the incidence of CRBSI at 6 months. Of the 147 patients on emergent hemodialysis, 125 had a tunneled catheter, with a CRBSI rate of 2.61 per 1,000 catheter days. The predominant organisms were Gram-negative rods (GNR). In the prospective study, we found that the dialysis catheter was colonized more frequently in patients on emergent hemodialysis than in those on scheduled hemodialysis. Colonization with GNR or Staphylococcus aureus was associated with subsequent CRBSI at 6 months follow-up. Patients undergoing emergent hemodialysis via tunneled catheter are predisposed to Gram-negative CRBSI. Culturing the heparin-lock solution may predict subsequent episodes of CRBSI if it shows colonization with GNR or Staphylococcus aureus. Prevention approaches in this population need to be studied further.
Chu, Hui-Ping; Brind, Joanne; Tomar, Rajeev; Hill, Susan
2012-10-01
The aim of this study was to review the incidence and type of central venous catheter-related bloodstream infection in children on treatment with home parenteral nutrition (PN) before and after the introduction of taurolidine. Taurolidine is a catheter lock solution that prevents biofilm formation and has broad-spectrum bactericidal and antifungal action. Its use in pediatric patients on PN has only been reported in case studies. A total of 19 children were reviewed, with the diagnoses of enteropathy (8 cases), short bowel syndrome (7 cases), and gastrointestinal dysmotility (4 cases). Incidence and type of sepsis were reviewed for 8 to 12 months pre- (when heparin was used) and 2 to 33 months postintroduction of the taurolidine catheter lock. There were 8.6 episodes of catheter-related bloodstream infections per 1000 catheter days with heparin and 1.1 episodes per 1000 catheter days with taurolidine (P=0.002). A total of 14 of the 19 patients (74%) had no infections for up to 33 months after changing to taurolidine. No reports of multiresistant organisms or adverse effects with taurolidine were found. Taurolidine line lock was associated with a decreased incidence of catheter-related bloodstream infections. This finding supports its use in patients with a history of septicemia on treatment with cyclical PN.
Reitzel, Ruth A; Rosenblatt, Joel; Hirsh-Ginsberg, Cheryl; Murray, Kimberly; Chaftari, Anne-Marie; Hachem, Ray; Raad, Issam
2016-09-01
The rapid, broad-spectrum, biofilm-eradicating activity of the combination of 0.01% nitroglycerin, 7% citrate, and 20% ethanol and its potential as a nonantibiotic, antimicrobial catheter lock solution (ACLS) were previously reported. Here, a nitroglycerin-citrate-ethanol (NiCE) ACLS optimized for clinical assessment was developed by reducing the nitroglycerin and citrate concentrations and increasing the ethanol concentration. Biofilm-eradicating activity was sustained when the ethanol concentration was increased from 20 to 22% which fully compensated for reducing the citrate concentration from 7% to 4% as well as the nitroglycerin concentration from 0.01% to 0.0015% or 0.003%. The optimized formulations demonstrated complete and rapid (2 h) eradication of methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-intermediate Staphylococcus aureus (VISA), methicillin-resistant Staphylococcus epidermidis (MRSE), vancomycin-resistant enterococci (VRE), multidrug-resistant (MDR) Pseudomonas aeruginosa, MDR Klebsiella pneumoniae, MDR Enterobacter cloacae, MDR Acinetobacter baumannii, MDR Escherichia coli, MDR Stenotrophomonas maltophilia, Candida albicans, and Candida glabrata biofilms. The optimized NiCE lock solutions demonstrated anticoagulant activities comparable to those of heparin lock solutions. NiCE lock solution was significantly more effective than taurolidine-citrate-heparin lock solution in eradicating biofilms of Staphylococcus aureus and Candida glabrata The optimized, nonantibiotic, heparin-free NiCE lock solution demonstrates rapid broad-spectrum biofilm eradication as well as effective anticoagulant activity, making NiCE a high-quality ACLS candidate for clinical assessment. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Kavosi, Zahra; Sarikhani Khorrami, Maryam; Keshavarz, Khosro; Jafari, Abdosaleh; Hashemi Meshkini, Amir; Safaei, Hamid Reza; Nikfar, Shekoufeh
2016-01-01
Prevention of catheter-related infection is of prime importance,. However, because of the risks caused by the leakage of circulating antibiotics and development of resistance to antibiotics, they are replaced by lock solutions. The aim of this study was to evaluate the efficacy and cost- effectiveness of taurolidine-citrate as a hemodialysis catheter lock solution compared to other common alternatives in Iran. To evaluate the efficacy of taurolidine-citrate, a systematic review was conducted by searching electronic databases. The outcomes of interest for cost-effectiveness analysis were as follows: "Catheter-related bacteremia episodes"; "catheter-related bacteremia-free survival"; "catheter thrombosis rate" for efficacy evaluation and "reduction of catheter-related infection". For evidence synthesis, a meta-analysis was conducted on the extracted efficacy data. To evaluate the cost of treatments, direct medical costs were included, and the incremental cost-effectiveness ratio was calculated for each comparison. The payers' (patients and insurance companies) perspectives were used for cost analysis. After carrying out the systematic process, three articles were included in the analysis. Considering 95% confidence interval, the relative difference was -0.16 (-0.25 to -0.07) for catheterrelated bacteremia episode, indicating that the rate of catheter-related infections in hemodialysis patients who used taurolidine-citrate was 16% less than in those hemodialysis patients who received heparin. Considering 95% confidence interval, the relative difference was 0.13 (-0.06 0.32) for catheter thrombosis, showing that the rate of catheter-related thrombosis in hemodialysis patients who used taurolidine-citrate was 13% more than in hemodialysis patients who received heparin. The results of this analysis indicated that taurolidine-citrate, compared to heparin, was more effective in preventing catheter-related infection; therefore, it could be considered as a superior strategy. Nevertheless, compared to heparin-gentamicin combination, taurolidine-citrate is an inferior strategy because of its higher cost and lower infection prevention. Compared to heparin, taurolidine-citrate is a superior option, but it is an inferior strategy compared to heparin-gentamicin combination. The clinical evidences on taurolidine-citrate, heparin and gentamicin/heparin are not sufficient for making confident decisions.
Merino, José L; Bouarich, Hanane; Pita, Mª José; Martínez, Patricia; Bueno, Blanca; Caldés, Silvia; Corchete, Elena; Jaldo, Mª Teresa; Espejo, Beatriz; Paraíso, Vicente
The application of antiseptic solution for handling tunnelled catheters is recommended in patients undergoing haemodialysis. These routine antiseptic procedures in handling catheters are crucial to avoid complications. We report an outbreak of Serratia marcescens (S. marcescens) bacteraemia in numerous haemodialysis units of the Community of Madrid. The first cases of bacteraemia due to S. marcescens were isolated in December 2014. The Preventive Medicine Services were informed of the detection of an atypical pathogen in several patients, suspecting a probable nosocomial outbreak. Information from 4 centres with similar S. marcescens bacteraemia was analysed. Twenty-one cases of bacteraemia related to S. marcescens were identified. The mean age of affected patients was 72±10 years. The mean time on haemodialysis of affected patients was 33±13 months (range: 3-83 months), the median time of tunnelled catheter was 22±13 months. In 11 cases the clinical picture was similar, with hypotension and general malaise during the haemodialysis session. Fever was present in a further 7 cases. In 3 cases the presentation was asymptomatic and was detected by blood cultures. All patients had tunnelled catheters (12 patients with catheter in the right jugular vein, 5 in the left jugular, 2 in the right femoral artery and 2 in the left subclavian artery). Gentamicin intravenous doses (1mg/kg) with catheter lock solution with ciprofloxacin post-dialysis were administered for 3 weeks in 6 patients. In 12 patients the treatment was ceftazidime (2g IV) plus catheter lock solution with the same antibiotic, for 2 weeks. Four patients received oral ciprofloxacin for 2 weeks, in one case together with IV vancomycin. The patients were asymptomatic and without new episodes 48hours after the treatment. No major complications were observed. The teams informed the health authorities of the situation, which then reported the presence of batches of antiseptic (chlorhexidine 0.05 and 2%) colonised by S. marcescens. Given the routine application of this antiseptic in handling catheters at these units, this was considered the source of contagion and new cases were not observed after the removal of the batches. The presence of bacteraemia due to unconventional germs should alert us to a potential outbreak. The application of a solution contaminated by S. marcescens in haemodialysis catheters was the source of bacteraemia. The intravenous antibiotic treatment and the catheter lock solution allowed an excellent survival of patients and catheters. Copyright © 2016 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.
Bustos, Cesar; Aguinaga, Aitziber; Carmona-Torre, Francisco; Del Pozo, Jose Luis
2014-01-01
Since the first description in 1982, totally implanted venous access ports have progressively improved patients’ quality of life and medical assistance when a medical condition requires the use of long-term venous access. Currently, they are part of the standard medical care for oncohematologic patients. However, apart from mechanical and thrombotic complications, there are also complications associated with biofilm development inside the catheters. These biofilms increase the cost of medical assistance and extend hospitalization. The most frequently involved micro-organisms in these infections are gram-positive cocci. Many efforts have been made to understand biofilm formation within the lumen catheters, and to resolve catheter-related infection once it has been established. Apart from systemic antibiotic treatment, the use of local catheter treatment (ie, antibiotic lock technique) is widely employed. Many different antimicrobial options have been tested, with different outcomes, in clinical and in in vitro assays. The stability of antibiotic concentration in the lock solution once instilled inside the catheter lumen remains unresolved. To prevent infection, it is mandatory to perform hand hygiene before catheter insertion and manipulation, and to disinfect catheter hubs, connectors, and injection ports before accessing the catheter. At present, there are still unresolved questions regarding the best antimicrobial agent for catheter-related bloodstream infection treatment and the duration of concentration stability of the antibiotic solution within the lumen of the port. PMID:24570595
Brito, Antonio Rafael de Oliveira; Nishinari, Kenji; Saad, Paulo Fernandes; Saad, Karen Ruggeri; Pereira, Monica Aparecida Tomé; Emídio, Suellen Cristina Dias; Yazbek, Guilherme; Bomfim, Guilherme Andre Zottele; Cavalcante, Rafael Noronha; Krutman, Mariana; Teivelis, Marcelo Passos; Pignataro, Bruno Soriano; Fonseca, Igor Yoshio Imagawa; Centofanti, Guilherme; Soares, Bruno Leonardo Freitas
2018-02-01
There are only 3 studies comparing the efficacy of 2 different types of lock used in totally implantable catheters regarding occlusion or reflux dysfunction. The present study contains the largest published casuistry (862 patients) and is the only one that analyzes 3 parameters: occlusion, reflux dysfunction, and flow dysfunction. This was a retrospective study of patients operated at a large oncology center and followed up in the outpatient clinic between 2007 and 2015. The patients were divided into 2 groups according to the type of lock: the Hep group (heparine), whose lock was composed of saline solution 0.9% with heparin (100 IU/mL) and the SS group (saline solution), whose lock was composed of saline solution 0.9%. The Hep group was composed of 270 patients (31%) and the SS group of 592 patients (69%). Regarding occlusion, there were 8 cases in the Hep group (2.96%) and 8 in the SS group (1.35%; P = 0.11); in relation to reflux dysfunction, there were 8 cases in the Hep group (2.96%) and 8 in the SS group (1.35%; P = 0.11); in relation to flow dysfunction, there was 1 case in the Hep group (0.37%) and 4 cases in the SS group (0.68%; P = 1). There was no statistically significant difference between the groups regarding occlusion, reflux dysfunction, and flow dysfunction. Copyright © 2017 Elsevier Inc. All rights reserved.
van de Wetering, Marianne D; van Woensel, Job B M; Lawrie, Theresa A
2013-11-25
This is an updated version of the review which was first published in the Cochrane Database of Systematic Reviews in 2006. Long-term central venous catheters (CVCs), including tunnelled CVCs (TCVCs) and totally implanted devices or ports (TIDs), are increasingly used when treating oncology patients. Despite international guidelines on sterile insertion and appropriate CVC maintenance and use, infection remains a common complication. These infections are mainly caused by Gram positive bacteria. Antimicrobial prevention strategies aimed at these micro-organisms could potentially decrease the majority of CVC infections. The aim of this review was to evaluate the efficacy of antibiotics in the prevention of Gram positive infections in long-term CVCs. To determine the efficacy of administering antibiotics prior to the insertion of long-term CVCs, or flushing or locking long-term CVCs with a combined antibiotic and heparin solution, or both, to prevent Gram positive catheter-related infections in adults and children receiving treatment for cancer. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (to June 2013) and the MEDLINE and EMBASE databases (1966 to 2013). Randomised controlled trials (RCTs) comparing prophylactic antibiotics given prior to long-term CVC insertion with no antibiotics, RCTs comparing a combined antibiotic and heparin solution with a heparin-only solution to flush or lock newly inserted long-term CVCs, and RCTs comparing a combination of these interventions in adults and children receiving treatment for cancer. Two authors independently selected studies, classified them and extracted data on to a pre-designed data collection form. We pooled data using the RevMan software version 5.2 and used random-effects (RE) model methods for meta-analyses. We included 11 trials with a total of 828 oncology patients (adults and children). We assessed most included studies to be at a low or unclear risk of bias. Five trials compared the use of antibiotics (vancomycin, teicoplanin or ceftazidime) given before the insertion of the long-term CVC with no antibiotics, and six trials compared antibiotics (vancomycin, amikacin or taurolidine) and heparin with a heparin-only solution for flushing or locking the long-term CVC after use. Administering an antibiotic prior to insertion of the CVC did not significantly reduce Gram positive catheter-related sepsis (CRS) (five trials, 360 adults; risk ratio (RR) 0.72, 95% confidence interval (CI) 0.33 to 1.58; I² = 5 2%; P = 0.41).Flushing and locking long-term CVCs with a combined antibiotic and heparin solution significantly reduced the risk of Gram positive catheter-related sepsis compared with a heparin-only solution (468 participants, mostly children; RR 0.47, 95% CI 0.28 to 0.80; I² = 0%; P = 0.005). For a baseline infection rate of 15%, this reduction translated into a number needed to treat (NNT) of 12 (95% CI 9 to 33) to prevent one catheter-related infection. We considered this evidence to be of a moderate quality. There was no benefit to administering antibiotics before the insertion of long-term CVCs to prevent Gram positive catheter-related infections. Flushing or locking long-term CVCs with a combined antibiotic and heparin solution appeared to reduce Gram positive catheter-related sepsis experienced in people at risk of neutropenia through chemotherapy or disease. Due to insufficient data it was not clear whether this applied equally to TCVCs and totally implanted devices (TIDs), or equally to adults and children. The use of a combined antibiotic and heparin solution may increase microbial antibiotic resistance, therefore it should be reserved for high risk people or where baseline CVC infection rates are high (> 15%). Further research is needed to identify high risk groups most likely to benefit.
Efficacy of Ethanol against Candida albicans and Staphylococcus aureus Polymicrobial Biofilms
Peters, Brian M.; Ward, Raven M.; Rane, Hallie S.; Lee, Samuel A.
2013-01-01
Candida albicans, an opportunistic fungus, and Staphylococcus aureus, a bacterial pathogen, are two clinically relevant biofilm-forming microbes responsible for a majority of catheter-related infections, with such infections often resulting in catheter loss and removal. Not only do these pathogens cause a substantial number of nosocomial infections independently, but also they are frequently found coexisting as polymicrobial biofilms on host and environmental surfaces. Antimicrobial lock therapy is a current strategy to sterilize infected catheters. However, the robustness of this technique against polymicrobial biofilms has remained largely untested. Due to its antimicrobial activity, safety, stability, and affordability, we tested the hypothesis that ethanol (EtOH) could serve as a potentially efficacious catheter lock solution against C. albicans and S. aureus biofilms. Therefore, we optimized the dose and time necessary to achieve killing of both monomicrobial and polymicrobial biofilms formed on polystyrene and silicone surfaces in a static microplate lock therapy model. Treatment with 30% EtOH for a minimum of 4 h was inhibitory for monomicrobial and polymicrobial biofilms, as evidenced by XTT {sodium 2,3-bis(2-methoxy-4-nitro-5-sulfophenyl)-5-[(phenylamino)carbonyl]-2H-tetrazolium hydroxide inner salt} metabolic activity assays and confocal microscopy. Experiments to determine the regrowth of microorganisms on silicone after EtOH treatment were also performed. Importantly, incubation with 30% EtOH for 4 h was sufficient to kill and inhibit the growth of C. albicans, while 50% EtOH was needed to completely inhibit the regrowth of S. aureus. In summary, we have systematically defined the dose and duration of EtOH treatment that are effective against and prevent regrowth of C. albicans and S. aureus monomicrobial and polymicrobial biofilms in an in vitro lock therapy model. PMID:23070170
Solinas, Gianfranca; Platini, Francesca; Trivellato, Maurizio; Rigo, Carla; Alabiso, Oscar; Galetto, Alessandra S
2017-07-14
Patients with cancer need stable venous access using central vascular devices like central venous ports and peripherally inserted central catheters that can be used for a wide range of indications. Numerous flushing protocols exist including different frequencies for catheter locking to maintain catheter patency. The aim of this retrospective study was to evaluate the incidence of lumen occlusion of central venous ports in a group of adult cancer patients, adopting a policy of locking with normal saline every three months. This is a single-center retrospective observational study. During follow-up, we analyzed adult cancer patients who had undergone port insertion from January 1st, 2007 to August 31st, 2014. Flushing and locking were performed every three months with a syringe containing normal saline. We collected data from 381 patients with ports inserted in subclavian vein (379 patients) and in the right jugular vein (2 patients). Locking was performed during 3-monthly follow-up visits. Median follow-up was 810 days (90-2700 days). Among 381 ports, 59 were removed; the reasons for removal were: end of use (45 cases), catheter rupture (9 cases), dislocation (3 cases) and catheter-related bloodstream infection (2 cases). We had no reports of lumen occlusion. Our data suggest that locking ports with normal saline every three months is not associated with an increased risk of lumen occlusion.
The effect of saline lock on phlebitis rates of patients in cardiac care units.
Eghbali-Babadi, Maryam; Ghadiriyan, Raziyeh; Hosseini, Sayed Mohsen
2015-01-01
Despite advances in the field of intravenous therapy, phlebitis is still a common complication of peripheral venous catheter and finding an appropriate solution to prevent and reduce the incidence of this complication remains challenging. One of the methods used in reducing the incidence of phlebitis is the use of saline lock, which is forgotten in most hospitals. Therefore, this study aimed to evaluate its impact on the incidence and severity of phlebitis. In a single-blind (the researcher) clinical trial, 88 patients with peripheral venous catheter admitted in cardiac care units in selected hospitals of Isfahan University of Medical Sciences, Iran, were selected through convenient sampling method. They were randomly divided into two groups of intervention and control groups using random number table. The intervention group received 3 ml of 0.9% normal saline sterilized before and after each intravenous drug or every 12 h. However, in the control group, the intravenous drugs were given as routine and saline lock was not used. The evaluation of intravenous catheter regarding the incidence of phlebitis and its degrees using Jackson's Visual Infusion Phlebitis Scale was performed 6 times within 72 h (every 12 h). Results were evaluated by SPSS software using descriptive statistics, Chi-square test, t-test, and Mann-Whitney test. Results showed that there was a statistically significant difference between the two groups regarding the degree of phlebitis (P = 0.003). The percentage of phlebitis incidence in the control group was 88.6% and in the intervention group was 43.2%. There was a statistically significant difference between the two groups (P < 0.001). The risk of incidence of phlebitis in the group without saline lock (control), compared to the intervention group, was 10.3 times greater (CI = 95%). The incidence of phlebitis in both groups increased with increase in the duration of catheter placement. The results of this study showed that the use of saline lock in the intervention group compared to the control group, in which saline lock was not used, can have a significant impact on reducing the incidence of phlebitis and its degree.
The effect of saline lock on phlebitis rates of patients in cardiac care units
Eghbali-Babadi, Maryam; Ghadiriyan, Raziyeh; Hosseini, Sayed Mohsen
2015-01-01
Background: Despite advances in the field of intravenous therapy, phlebitis is still a common complication of peripheral venous catheter and finding an appropriate solution to prevent and reduce the incidence of this complication remains challenging. One of the methods used in reducing the incidence of phlebitis is the use of saline lock, which is forgotten in most hospitals. Therefore, this study aimed to evaluate its impact on the incidence and severity of phlebitis. Materials and Methods: In a single-blind (the researcher) clinical trial, 88 patients with peripheral venous catheter admitted in cardiac care units in selected hospitals of Isfahan University of Medical Sciences, Iran, were selected through convenient sampling method. They were randomly divided into two groups of intervention and control groups using random number table. The intervention group received 3 ml of 0.9% normal saline sterilized before and after each intravenous drug or every 12 h. However, in the control group, the intravenous drugs were given as routine and saline lock was not used. The evaluation of intravenous catheter regarding the incidence of phlebitis and its degrees using Jackson's Visual Infusion Phlebitis Scale was performed 6 times within 72 h (every 12 h). Results were evaluated by SPSS software using descriptive statistics, Chi-square test, t-test, and Mann–Whitney test. Results: Results showed that there was a statistically significant difference between the two groups regarding the degree of phlebitis (P = 0.003). The percentage of phlebitis incidence in the control group was 88.6% and in the intervention group was 43.2%. There was a statistically significant difference between the two groups (P < 0.001). The risk of incidence of phlebitis in the group without saline lock (control), compared to the intervention group, was 10.3 times greater (CI = 95%). The incidence of phlebitis in both groups increased with increase in the duration of catheter placement. Conclusions: The results of this study showed that the use of saline lock in the intervention group compared to the control group, in which saline lock was not used, can have a significant impact on reducing the incidence of phlebitis and its degree. PMID:26257807
Infection and hemodialysis access: an updated review.
Gupta, Vineet; Yassin, Mohamed H
2013-06-01
The incidence of end-stage renal disease (ESRD) has almost doubled over past 2 decades. Despite decreasing overall hospital admission rates for ESRD population, the rate of infection-related hospitalizations has steadily increased. Infection remains the second most common cause of mortality in this patient population. Specifically, in the hemodialysis (HD) patients, the vascular access related infections are the most common identifiable source of infection. This concise review provides an update on the bacteremia related to vascular access primarily the catheters (Catheter Related Blood Stream Infection- CRBSI) in HD patients emphasizing on the determinants ranging from the epidemiology to pathogenesis, risk factors, cost implications and prevention. Staphylococcus aureus, coagulase negative Staphylococci, and Enterococci are the most common causative microorganisms implicated in CRBSI. The pathogenesis of CRBSI includes organism entry into the blood stream followed by adherence to catheter, colonization and biofilm formation. Vascular access type, catheter position, and prior bacteremic episodes are strongly associated with blood stream infection. Preventive measures should be multidisciplinary in nature and should include avoidance of central venous catheters, best practices for catheter care, surveillance, antimicrobial catheter lock solutions, and use of antibiotic impregnated catheters.
Passerini de Rossi, Beatriz; Feldman, Laureana; Pineda, María Saliba; Vay, Carlos; Franco, Mirta
2012-09-01
The aim of this study was to compare the in vitro activity of ethanol, EDTA and levofloxacin (Levo), alone or in combination, on biofilms of Stenotrophomonas maltophilia recovered from patients with catheter-related bloodstream infections (CRBSIs) at a university hospital in Argentina. First, 24 and 48 h biofilms were formed in microtitre plates and challenged with 25 or 40 % ethanol for 1 h. Biofilms, of the 14 local isolates and from the reference strain K279a, were eradicated after both treatments as shown by plate counts and the regrowth technique. Second, 24 h biofilms of all isolates were established in silicone catheter segments and challenged with 25 or 40 % ethanol, Levo (2.5 mg ml(-1)), EDTA (30 mg ml(-1)), 25 % ethanol-EDTA or Levo-EDTA for 1, 3 and 24 h. Viable counts of biofilms treated for 1 h with 25 or 40 % ethanol or 25 % ethanol-EDTA were under the limit of detection. Killing of biofilms by Levo or Levo-EDTA was gradual and it was only after 24 h of treatment that no differences could be seen between the effects of these catheter lock solutions (CLSs) and those of ethanol (P>0.05). Levo-EDTA, in combination, did not act synergistically against biofilms. After 24 h of exposure, EDTA did not eradicate biofilms but reduced biofilm survival rates to 1-5 %. The effect of the different CLSs on biomass reduction, estimated by crystal violet staining, was highly dependent on the isolate, and the most effective agents were 25 and 40 % ethanol. Our results suggest that when used as a CLS for short periods, ethanol at low concentrations, alone or in combination with a chelator, can decontaminate the line from S. maltophilia in cases of CRBSI and help, in conjunction with systemic antibiotics, in the retention of precious vascular catheters.
Paul DiMondi, V; Townsend, Mary L; Johnson, Melissa; Durkin, Michael
2014-07-01
Antifungal catheter lock therapy (AfLT) with liposomal amphotericin B has been used in the treatment of pediatric central line infections caused by Candida species; however, reports describing the use of liposomal amphotericin B lock therapy in the adult hemodialysis patient population are lacking. Management of central line-associated candidemia with systemic therapy alone is often challenging due to the propensity of Candida species to form biofilms on foreign bodies. We describe a 64-year-old woman who was receiving hemodialysis 3 times/week and was hospitalized with persistent fungemia. Despite receiving intravenous micafungin, she had multiple positive blood cultures for Candida albicans, which finally cleared after 7 days. Her double-lumen catheter was considered the most likely nidus of infection. Although catheter removal would have been preferred, this was not possible given her vasculopathy, history of multiple bloodstream infections, and lack of other available sites for vascular access. Catheter exchange was performed, and liposomal amphotericin B AfLT was administered in combination with intravenous micafungin for a total of 6 days. During this time, the patient experienced no discernible adverse effects secondary to AfLT. At discharge, AfLT was discontinued, and intravenous micafungin was changed to oral fluconazole. After 6 months of treatment, the patient remained culture negative and maintained her dialysis access. To our knowledge, this is the first case report of liposomal amphotericin B catheter lock therapy used to manage a persistent C. albicans bloodstream infection in an adult receiving hemodialysis. AfLT is a novel concept for treating catheter-associated fungal infections. Liposomal amphotericin B was chosen based on its favorable in vitro activity against Candida species biofilms in catheter lock environments. We identified several barriers to implementing AfLT, and these issues may prohibit the use of AfLT. This case report illustrates the benefits and challenges of managing catheter-associated fungal infections with AfLT. Further study is required to examine the efficacy, safety, and feasibility of this approach. © 2014 Pharmacotherapy Publications, Inc.
Peterson, William J.; Maya, Ivan D.; Carlton, Donna; Estrada, Erin; Allon, Michael
2008-01-01
Background Catheter-related bacteremia (CRB) is a frequent complication of tunneled dialysis catheters, and Enterococcus is a common infecting organism. CRB may be treated by instilling an antibiotic lock into the catheter lumen, in conjunction with systemic antibiotics. The efficacy of this approach in Enterococcus bacteremia is unknown. Design Quality improvement report. Setting and participants 64 catheter-dependent hemodialysis outpatients with vancomycin-sensitive Enterococcus bacteremia treated with a uniform antibiotic lock protocol. Clinical outcomes were tracked prospectively. Quality improvement plans Patients received intravenous vancomycin for 3 weeks, in conjunction with a vancomycin lock instilled into both catheter lumens after each dialysis session. Measures Treatment failure was defined as persistent fever 48 hours after initiation of antibiotics or recurrent Enterococcus bacteremia within 90 days. A clinical cure was defined as fever resolution without recurrent bacteremia. Major infection-related complications within 6 months were documented. Results Treatment failure occurred in 25 patients (39%), due to persistent fever in 10, and recurrent bacteremia in 15. Treatment success occurred in 39 patients (61%). A serious complication of Enterococcus CRB occurred in 4 of 64 patients (6%), endocarditis in 1 and osteomyelitis in 3. The frequency of serious complications was 16% (4/25) in patients with treatment failure, as compared with 0% (0/39) in those with treatment success (P=0.01). Limitations This was a single-center study. We did not measure serum vancomycin levels. Conclusions An antibiotic lock protocol permits catheter salvage in 61% of hemodialysis patients with Enterococcus CRB. Serious complications occur in 6% of patients, and are more common in those with treatment failure. PMID:18848379
Minimizing Hemodialysis Catheter Dysfunction: An Ounce of Prevention
Lee, Timmy; Lok, Charmaine; Vazquez, Miguel; Moist, Louise; Maya, Ivan; Mokrzycki, Michele
2012-01-01
The maintenance of tunneled catheter (TC) patency is critical for the provision of adequate hemodialysis in patients who are TC-dependent. TC dysfunction results in the need for costly and inconvenient interventions, and reduced quality of life. Since the introduction of TCs in the late 1980s, heparin catheter lock has been the standard prophylactic regimen for the prevention of TC dysfunction. More recently, alternative catheter locking agents have emerged, and in some cases have shown to be superior to heparin lock with respect to improving TC patency and reducing TC-associated infections. These include citrate, tissue plasminogen activator, and a novel agent containing sodium citrate, methylene blue, methylparaben, and propylparaben. In addition, prophylaxis using oral anticoagulants/antiplatelet agents, including warfarin, aspirin, ticlodipine, as well as the use of modified heparin-coated catheters have also been studied for the prevention of TC dysfunction with variable results. The use of oral anticoagulants and/or antiplatelet agents as primary or secondary prevention of TC dysfunction must be weighed against their potential adverse effects, and should be individualized for each patient. PMID:22518310
Venipuncture versus peripheral catheter: do infusions alter laboratory results?
Hambleton, Victoria Lerma; Gómez, Ignacio Arribas; Andreu, Francisco A Bernabeu
2014-01-01
Our aim was to evaluate the equivalence between analytic parameters from blood samples obtained from a saline solution lock device used for the infusion of drugs and those from venipuncture. In our emergency department, patients bearing a saline solution lock device have blood extracted by venipuncture to avoid possible contamination of the sample. Adults from the emergency department with a saline solution lock device who required laboratory tests were selected as candidates for this cross-sectional observational study. Infusions were halted and flushed with 0.9% saline solution; 2 minutes later, 2 mL of blood was drawn and discarded, and the corresponding laboratory tubes were filled. Immediately after, another sample was withdrawn from the opposite extremity by venipuncture. Both samples were analyzed for hematology, biochemistry, venous blood gases, and coagulation parameters. Concordance was evaluated by use of the intraclass correlation coefficient with its 95% confidence intervals; Bland-Altman plots were used to illustrate the percentage of samples with differences exceeding 2 SDs. The mean differences were also checked to detect those exceeding the laboratory's systematic error. An intraclass correlation coefficient of over 0.9 was achieved for all parameters except for pH, partial pressure of carbon dioxide, and partial pressure of oxygen. Differences of over 2 SDs were found in fewer than 10% of all parameters. None of them exceeded 3 SDs, except for pH and venous blood gases. All parameters showed differences below the laboratory's accepted systematic error except for pH and venous blood gases. Blood samples extracted from a peripheral catheter with or without drug infusions are valid for the analysis of hematology, biochemistry, and coagulation parameters but not for venous blood gases. Nurses should know the benefits of using an existing peripheral catheter for drawing blood samples for laboratory analysis even when infusing commonly used drugs. Emergency nurses should consider collecting blood specimens from a venous access device regardless of the type of drug infusions administered, because it is a safe, simple, and fast technique, which is time efficient when treating patients with limited venous access sites. This procedure reduces patient discomfort and the risk of complications related to venipunctures. Copyright © 2014 Emergency Nurses Association. Published by Mosby, Inc. All rights reserved.
Randolph, Adrienne G; Cook, Deborah J; Gonzales, Calle A; Andrew, Maureen
1998-01-01
Objective: To evaluate the effect of heparin on duration of catheter patency and on prevention of complications associated with use of peripheral venous and arterial catheters. Design: Critical appraisal and meta-analysis of 26 randomised controlled trials that evaluated infusion of heparin intermittently or continuously. Thirteen trials of peripheral venous catheters and two of peripheral arterial catheters met criteria for inclusion. Main outcome measures: Data on the populations, interventions, outcomes, and methodological quality. Results: For peripheral venous catheters locked between use flushing with 10 U/ml of heparin instead of normal saline did not reduce the incidence of catheter clotting and phlebitis or improve catheter patency. When heparin was given as a continuous infusion at 1 U/ml the risk of phlebitis decreased (relative risk 0.55; 95% confidence interval 0.39 to 0.77), the duration of patency increased, and infusion failure was reduced (0.88; 0.72 to 1.07). Heparin significantly prolonged duration of patency of radial artery catheters and decreased the risk of clot formation (0.51; 0.42 to 0.61). Conclusions: Use of intermittent heparin flushes at doses of 10 U/ml in peripheral venous catheters locked between use had no benefit over normal saline flush. Infusion of low dose heparin through a peripheral arterial catheter prolonged the duration of patency but further study is needed to establish its benefit for peripheral venous catheters. Key messages Despite almost universal use, agreement has not been reached on the need to administer heparin through peripheral intravascular catheters The results of 13 trials on peripheral venous catheters and two trials on peripheral arterial catheters were critically appraised to clarify what evidence supports the use of heparin Flushing peripheral venous catheters locked between use with heparinised saline at 10 U/ml is no more beneficial than flushing with normal saline Heparin significantly prolongs the duration of peripheral arterial catheter patency and decreases the risk of clot formation In peripheral venous catheters heparin added to the infusion at 1 U/ml decreases phlebitis and may prolong duration of catheter patency and decrease infusion failure PMID:9550955
Corbella, Marta; Brandolini, Micaela; Cambieri, Patrizia; Decembrino, Nunzia; Pagani, Michele; Bottazzi, Andrea; Muzzi, Alba; Zecca, Marco; Mariani, Bianca; Marone, Piero
2017-07-01
We report the case of a catheter-related bloodstream infection caused by Chryseobacterium indologenes, an uncommon and multi-resistant pathogen, in a pediatric patient with a long-term vascular access device placed for chemotherapy treatment. The infection was successfully treated with ciprofloxacin antibiotic-lock therapy. This is the first report on successful salvage of a long-term device colonized by multi-resistant Chryseobacterium indologenes.
Incompatibility of Contrast Medium and Trisodium Citrate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Delcour, Christian, E-mail: christian.delcour@chu-charleroi.be; Bruninx, Guy
2013-02-15
To test the compatibility of trisodium citrate, a catheter lock solution, with iodinated contrast medium. Iohexol, iobitridol, iodixanol, ioxaglate, ioxithalamate, iomeprol, and iopromide were tested. In all tests, 2 ml of contrast medium were mixed with 2 ml of trisodium citrate solution. Iodixanol and ioxaglate provoked a highly viscous gluelike precipitation when mixed with trisodium citrate. A brief transient precipitate was observed with iohexol, iomeprol, and ioxithalamate. Permanent precipitation occurred with iobitridol and iopromide. One must be aware of the potential for precipitation when contrast medium is mixed with trisodium citrate solution. Before trisodium citrate solution is injected, the cathetermore » should be thoroughly flushed with saline if a contrast medium has previously been injected through it.« less
[Anatomical and clinical evaluation regarding the removal of the peritoneal dialysis catheter].
Tăranu, T; Covic, A; Târcoveanu, E; Florea, Laura
2005-01-01
To describe CAPD technique survival and causes for catheter removal. The study included 320 end stage renal disease (ESRD) patients, initiated on CAPD between 1995-2003. Definitive catheter removal was required in 44 cases (15.1%), 11 of these (3.79%) receiving renal transplant. Causes for catheter removal were: mechanical obstruction by fibrin (8 cases/2.75%), obstruction by tub bower (1 case/0.34%), by omental muff (6 cases/2%); abdominal wall sepsis (30 cases/ 10.3%); non-responsive bacterial peritonitis (13 cases/4.05%), fungal peritonitis (7 cases/ 2.4%), fecal peritonitis (2 cases/0.68%); transfer to hemodialysis program (31 cases/10.6%); renal transplant (11 cases/3.79%); emergency surgical pathology for: necrotic-hemorrhagic pancreatitis (two cases), intestinal occlusions (six cases), locked hernias (three cases) and locked eventrations(three cases), appendicular peritonitis (two cases). Mortality associated with these procedures and underlying pathology was 1.73%.
Animal models to investigate fungal biofilm formation.
Chandra, Jyotsna; Pearlman, Eric; Ghannoum, Mahmoud A
2014-01-01
Microbial biofilms play an essential role in several infectious diseases and are defined as extensive communities of sessile organisms irreversibly associated with a surface, encased within a polysaccharide-rich extracellular matrix (ECM), and exhibiting enhanced resistance to antimicrobial drugs. Forming a biofilm provides the microbes protection from environmental stresses due to contaminants, nutritional depletion, or imbalances, but is dangerous to human health due to their inherent robustness and elevated resistance.The use of indwelling medical devices (e.g., central venous catheters, CVCs) in current therapeutic practice is associated with 80-90 % of hospital-acquired bloodstream and deep tissue infections. Most cases of catheter-related bloodstream infections (CRBSIs) involve colonization of microorganisms on catheter surfaces where they form a biofilm. Additionally, Fusarium solani and F. oxysporum were the causative organisms of the 2005/2006 outbreak of contact lens-associated fungal keratitis in the United States, Europe, the UK, and Singapore, and these infections involved formation of biofilms on contact lens. Fungal biofilm formation is studied using a number of techniques, involving the use of a wide variety of substrates and growth conditions. In vitro techniques involving the use of confocal scanning laser/scanning electron microscopy, metabolic activity assay, dry weight measurements, and antifungal susceptibility assays are increasingly used by investigators to quantify and evaluate biofilm morphology. However, there are not many in vivo models used to validate biofilm-associated infections. In this protocol, we describe a clinically relevant rabbit model of C. albicans biofilm-associated catheter infection to evaluate the morphology, topography, and architecture of fungal biofilms. We also describe a murine model of contact lens-associated Fusarium keratitis.Evaluation of the formation of fungal biofilms on catheters in vivo, their analysis using scanning electron microscopy (SEM) and quantitative catheter culture (QCC), and treatment of biofilms using antimicrobial lock therapy can be completed in ~20-25 days using the described methods. The rabbit model has utility in evaluating the efficacy of lock solutions. In addition, the murine model of contact lens-associated Fusarium keratitis enables characterizing/comparing the formation of Fusarium biofilms on contact lenses in vitro and determining their role in vivo.
Narayanan, Amoolya; Nair, Meera S; Karumathil, Deepti P; Baskaran, Sangeetha A; Venkitanarayanan, Kumar; Amalaradjou, Mary Anne Roshni
2016-01-01
Acinetobacter baumannii is a major nosocomial pathogen causing human infections with significant mortality rates. In most cases, infections are acquired through exposure to A. baumannii biofilms that persist on contaminated hospital equipment and surfaces. Thus, it is imperative to develop effective measures for controlling A. baumannii biofilms in nosocomial settings. This study investigated the efficacy of octenidine dihydrochloride (OH), a new generation disinfectant for reducing A. baumannii biofilms on polystyrene, stainless steel and catheters. OH at 0.3% (5 mM), 0.6% (10 mM), and 0.9% (15 mM) was effective in significantly inactivating A. baumannii biofilms on all tested surfaces (P < 0.05). Furthermore, OH was equally effective in inactivating biofilms of multidrug resistant and drug susceptible A. baumannii isolates. In addition, confocal imaging revealed the predominance of dead cells in the OH-treated samples in comparison to the control. Further, scanning electron microscopy of biofilms formed on catheters revealed that OH treatment significantly reduced A. baumannii biofilm populations in corroboration with our antibiofilm assay. These data underscore the efficacy of OH in inactivating A. baumannii biofilms, thereby suggesting its potential use as a disinfectant or a catheter lock solution to control A. baumannii infections.
Wang, Rui; Zhang, Ming-Guang; Luo, Ou; He, Liu; Li, Jia-Xin; Tang, Yun-Jing; Luo, Yan-Li; Zhou, Min; Tang, Li; Zhang, Zong-Xia; Wu, Hao; Chen, Xin-Zu
2015-01-01
Abstract A prospective randomized, controlled, single-blinded trial to compare the effectiveness and safety of heparin saline (HS) to those of normal saline (NS) as flushing and locking solutions for peripheral venous catheter (PVC) in decompensated liver cirrhosis (DLC) patients. Patients with DLC at our institution between April 2012 and March 2013 were enrolled after obtaining informed consent. The patients were randomly allocated into 2 groups: the NS group received preservative-free 0.9% sodium chloride as the flushing and locking solution, while the HS group received HS (50 U/mL). PVC-related events and the duration of PVC maintenance were compared between the 2 groups. Moreover, the preinfusion and postinfusion levels of prothrombin time (PT), activated partial thromboplastin time (APTT), and platelet (PLT) were also compared. A total of 32 and 36 DLC patients in the NS (125 PVCs) and HS (65 PVCs) groups, respectively, were analyzed. Baseline characteristics, including gender, age, Child–Pugh grade, PVC type and administration of anticoagulant, and irritant agents, were comparable between the 2 groups (P > 0.05). The maintenance times of the HS and NS groups were 80.27 ± 26.47 and 84.19 ± 29.32 hours, respectively (P = 0.397). Removal of PVC for abnormal reasons occurred in 30.7% and 22.4% of patients in the HS and NS groups (P = 0.208). The PVC occlusion rates were 6.2% and 5.6% in the HS and NS groups, respectively (OR = 1.11, 95% CI 0.31–3.92). The PT, APTT, and PLT levels were comparable between the 2 groups both before and after infusion (P > 0.05). Incremental analyses showed that Child–Pugh grade C might be a risk factor for the suppression of PLT in the HS group. We consider NS to be as effective as and safer than conventional HS for flushing and locking PVC in decompensated liver cirrhosis patients. PMID:26252305
CUA Annual Meeting Abstracts addition.
2012-08-01
: Foley catheters are assumed to drain the bladder to completion. We have previously shown that dependent loops along the drainage tubing create air-locks, which obstruct antegrade urine flow and result in un-drained residual bladder urine. We hypothesized that drainage characteristics of Foley catheters remain poorly understood by urologists and general surgeons. We conducted a nationwide survey of general surgery and urology training program faculty and residents, to assess perceptions of Foley catheter drainage. We designed a novel catheter drainage tube/bag that eliminates air-locks. : An anonymous illustrated questionnaire assessing Foley catheter use patterns and perception was sent to general surgery and urology residency programs (N=108) nationwide. A modified catheter drainage tube/bag unit was designed and tested. An ex vivo catheterized bladder model was designed to measure and compare urine drainage rates with the standard drainage system, versus with our novel design. : A total of 307 responses were collected from residents (55%) and faculty (45%); responses were similar among both groups (p<0.05). The majority reported that at their centers Foley catheter drainage tubes are generally positioned with a dependent loop (94.1%), and, that positioning with a dependent loop, versus without (78.1%) promoted optimal drainage. Antegrade drainage does not occur with a traditional drainage system when a >5.5 inch dependent loop in place. With our proposed design, which eliminates dependent loops, the bladder model emptied to completion consistently. : Traditional Foley catheter drainage systems, as commonly used, evacuate the bladder sub- optimally. More reliable and complete bladder drainage may decrease the incidence of catheter related UTI. The novel modified Foley catheter drainage tube/bag design presented here eliminates dependent loops, to optimize antegrade drainage.
Narayanan, Amoolya; Nair, Meera S.; Karumathil, Deepti P.; Baskaran, Sangeetha A.; Venkitanarayanan, Kumar; Amalaradjou, Mary Anne Roshni
2016-01-01
Acinetobacter baumannii is a major nosocomial pathogen causing human infections with significant mortality rates. In most cases, infections are acquired through exposure to A. baumannii biofilms that persist on contaminated hospital equipment and surfaces. Thus, it is imperative to develop effective measures for controlling A. baumannii biofilms in nosocomial settings. This study investigated the efficacy of octenidine dihydrochloride (OH), a new generation disinfectant for reducing A. baumannii biofilms on polystyrene, stainless steel and catheters. OH at 0.3% (5 mM), 0.6% (10 mM), and 0.9% (15 mM) was effective in significantly inactivating A. baumannii biofilms on all tested surfaces (P < 0.05). Furthermore, OH was equally effective in inactivating biofilms of multidrug resistant and drug susceptible A. baumannii isolates. In addition, confocal imaging revealed the predominance of dead cells in the OH-treated samples in comparison to the control. Further, scanning electron microscopy of biofilms formed on catheters revealed that OH treatment significantly reduced A. baumannii biofilm populations in corroboration with our antibiofilm assay. These data underscore the efficacy of OH in inactivating A. baumannii biofilms, thereby suggesting its potential use as a disinfectant or a catheter lock solution to control A. baumannii infections. PMID:27375572
Traditional Foley drainage systems--do they drain the bladder?
Garcia, Maurice M; Gulati, Shelly; Liepmann, Dorian; Stackhouse, G Bennett; Greene, Kirsten; Stoller, Marshall L
2007-01-01
Foley catheters are assumed to drain the bladder to completion. Drainage characteristics of Foley catheter systems are poorly understood. To investigate unrecognized retained urine with Foley catheter drainage systems, bladder volumes of hospitalized patients were measured with bladder scan ultrasound volumetrics. Additionally, an in vitro bench top mock bladder and urinary catheter system was developed to understand the etiology of such residual volumes. A novel drainage tube design that optimizes indwelling catheter drainage was also designed. Bedside bladder ultrasound volumetric studies were performed on patients hospitalized in ward and intensive care unit. If residual urine was identified the drainage tubing was manipulated to facilitate drainage. An ex vivo bladder-urinary catheter model was designed to measure flow rates and pressures within the drainage tubing of a traditional and a novel drainage tube system. A total of 75 patients in the intensive care unit underwent bladder ultrasound volumetrics. Mean residual volume was 96 ml (range 4 to 290). In 75 patients on the hospital ward mean residual volume was 136 ml (range 22 to 647). In the experimental model we found that for every 1 cm in curl height, obstruction pressure increased by 1 cm H2O within the artificial bladder. In contrast, the novel spiral-shaped drainage tube demonstrated rapid (0.5 cc per second), continuous and complete (100%) reservoir drainage in all trials. Traditional Foley catheter drainage systems evacuate the bladder suboptimally. Outflow obstruction is caused by air-locks that develop within curled redundant drainage tubing segments. The novel drainage tubing design eliminates gravity dependent curls and associated air-locks, optimizes flow, and minimizes residual bladder urine.
McGrath, Eric; Du, Wei; Rajpurkar, Madhvi
2018-03-01
Ethanol lock therapy (ELT) with systemic antimicrobial therapy is a promising therapy for catheter-related infection (CRI). The impact of ELT timing on treatment efficacy and costs is unknown. A prospective study was conducted in the Hematology/Oncology Unit at the Children's Hospital of Michigan. Patients with suspected CRI were randomized to Preemptive ELT arm or Rescue ELT arm after positive culture. Five cases in Preemptive arm and 9 in Rescue arm had a confirmed CRI. All cases cleared infection with line salvage with no adverse events due to ELT or recurrence within 14 days. Our data showed a trend toward 36% reduction in average hospital costs and 40% reduction in average length of stay in Preemptive arm over Rescue arm. Although a small study, our data on preemptive ELT with systemic antimicrobial therapy suggest a potentially important treatment strategy in reducing length of stay as well as hospital costs.
Segura, M; Alía, C; Valverde, J; Franch, G; Torres Rodríguez, J M; Sitges-Serra, A
1990-01-01
An in vivo model of hub-related catheter sepsis in rabbits is reported. The model was used to investigate the protection offered by a new hub design against external contamination by Pseudomonas aeruginosa or Staphylococcus epidermidis and to reassess the diagnostic value of the semiquantitative culture method in bacteremia of endoluminal origin. Contamination of conventional Luer-Lock connectors was followed by clinical sepsis, positive catheter segment cultures, or both, whereas contamination of the new hub was followed by complete protection. Clinical and bacteriological discrepancies observed between contamination with P. aeruginosa and S. epidermidis suggest that the virulence of microorganisms may account for differences in the natural history of hub-originated catheter sepsis. The semiquantitative extraluminal method for catheter culture yielded less than 15 CFU in three animals with proven bacteremia and should not be used as the "gold standard" to define catheter-related bacteremia. PMID:2254430
Incidence and Determinants of Port Occlusions in Cancer Outpatients: A Prospective Cohort Study.
Milani, Alessandra; Mazzocco, Ketti; Gandini, Sara; Pravettoni, Gabriella; Libutti, Livio; Zencovich, Claudia; Sbriglia, Ada; Pari, Chiara; Magon, Giorgio; Saiani, Luisa
Normal saline is considered a safe alternative for heparin as a locking solution in totally implantable venous access devices. The incidence rate of partial occlusion with the use of normal saline (easy injection, impossible aspiration) is estimated at 4%. The aim of this study was to investigate determinants of partial occlusions with the use of normal saline solution and the maintenance of positive pressure in the catheter. We enrolled 218 patients with different solid tumors who underwent pharmacologic treatment through the port with different frequencies: from once every week to at least once every month. The port was flushed with normal saline solution keeping a positive pressure in the catheter. We performed 4111 observations and documented normal port functioning in 99% of observations (n = 4057) and partial occlusions in 1% of observations (n = 54). Partial occlusions were significantly associated with frequency of port flushing (P < .05), chemotherapy (P < .001), and blood sample collection (P < .001). The use of positive pressure in addition to normal saline reduces the incidence rate of partial occlusions. The type of treatment, blood sample collection, and treatment schedule are important determinants of partial occlusions. Nurses play a key role in maintaining a functioning port using positive pressure during the flushing techniques. Certain risk factors must be monitored to prevent partial occlusions, and certain patients are more likely to present with port-related problems.
Mishkin, G J
2007-01-01
More than 20% of the world's population use a catheter for dialysis, despite guidelines limiting their use. Although the structure and design of the catheters differ by manufacturer, the material used in central venous catheters and peritoneal dialysis catheters are the same across manufacturers. Given the long-term use of these catheters in the dialysis population, the good compatibility of the antiseptics and disinfectants used on the catheters is imperative to prevent failure and cracking of the catheter material. Tensile strengths of commercially available catheters were measured after exposure to commonly used disinfectants. The tensile strength was then compared between the catheters by analyzing the displacement vs. force (N) curves produced during the evaluation. A total of 44 catheter lumens were evaluated. The electrolytically produced sodium hypochlorite solution, Alcavis 50/ExSept Plus, was the only solution shown to be compatible with all three catheter materials resulting in a deviation of less than 10% for each of the different catheter types. Electrolytically produced sodium hypochlorite solutions were the only solutions in this study that did not alter the physical properties of any of the catheters after long-term exposure.
New materials and devices for preventing catheter-related infections
2011-01-01
Catheters are the leading source of bloodstream infections for patients in the intensive care unit (ICU). Comprehensive unit-based programs have proven to be effective in decreasing catheter-related bloodstream infections (CR-BSIs). ICU rates of CR-BSI higher than 2 per 1,000 catheter-days are no longer acceptable. The locally adapted list of preventive measures should include skin antisepsis with an alcoholic preparation, maximal barrier precautions, a strict catheter maintenance policy, and removal of unnecessary catheters. The development of new technologies capable of further decreasing the now low CR-BSI rate is a major challenge. Recently, new materials that decrease the risk of skin-to-vein bacterial migration, such as new antiseptic dressings, were extensively tested. Antimicrobial-coated catheters can prevent CR-BSI but have a theoretical risk of selecting resistant bacteria. An antimicrobial or antiseptic lock may prevent bacterial migration from the hub to the bloodstream. This review discusses the available knowledge about these new technologies. PMID:21906266
Ferreira Chacon, Julieta Maria; Hato de Almeida, Emília; de Lourdes Simões, Regina; Lazzarin C Ozório, Viviane; Alves, Benaia Cândida; Mello de Andréa, Maria Lydia; Santiago Biernat, Marcela; Biernat, João Carlos
2011-01-01
Contamination of central catheters is frequent, and biofilm perpetuates infections. Heparin does not protect against infections because it has no antibiotic action. Minocycline and edetic acid (M-EDTA), a potent calcium chelating agent that destroys bacterial and fungal cell membrane and disrupts biofilm, may be an alternative to allow the associated antibiotic to act locally at a high and safe concentration. Fifty children with cancer and a port-a-cath were followed up: 26 received heparin (group 1) and 24 M-EDTA (group 2). A total of 762 serial prospective blood cultures were obtained, 387 from group 1 and 375 from group 2. In group 1 (heparin), 19 blood cultures were positive, and infection incidence was 73.1% (19/26 ports). In group 2 (M-EDTA), 5 blood cultures were positive, and the incidence rate was 20.8% (5/24 ports). M-EDTA, compared with heparin, prevents and treats catheter infections, and is a promising alternative to decrease sepsis during chemotherapy. Copyright © 2011 S. Karger AG, Basel.
Catheter port cleansing techniques and the entry of povidone-iodine into the epidural space.
Paice, J A; DuPen, A; Schwertz, D
1999-04-01
To determine whether three epidural catheter port cleansing techniques used to apply a povidone-iodine solution differed with respect to the introduction of this solution through the epidural catheter. Experimental. Laboratory. Five DuPen (Davol, Cranston, RI) epidural catheters. Five DuPen epidural catheters each were cleansed twice with (a) a commercially available 10% povidone-iodine swabstick, (b) a commercially available pledget impregnated with 10% povidone-iodine, and (c) a gauze pad saturated with 10% povidone-iodine. The order of cleansing was randomized. Each solution was used to clean the port for 30 seconds, and the port was allowed to dry for 30 seconds, similar to the technique used in the clinical setting. After cleaning the catheter port, water was injected through the catheter, and the solution from the tip of the catheter was analyzed using absorbance spectrophotometry. Cleansing techniques, presence of povidone-iodine in catheter. A statistically significant difference existed between the three cleansing techniques, with the pledget yielding the lowest values of povidone-iodine contamination of the epidural catheter (Freidman test, p = 0.02). Use of pledgets allowed the least amount of povidone-iodine to enter the epidural catheter as compared with the swabsticks or gauze pads. Commercially available pledgets used to cleanse catheter injection ports may limit the introduction of 10% povidone-iodine into the epidural or intrathecal space.
Blocked urinary catheters: solutions are not the only solution.
Williams, Cath; Tonkin, Sharon
2003-07-01
The use of catheter maintenance solutions to manage clients whose catheters block has long been a subject for debate. An understanding of the causes of blockage, and awareness of appropriate management may reduce frequency of blockage and reduce unnecessary interruptions to a closed urinary drainage system.
Moore, Katherine N; Hunter, Kathleen F; McGinnis, Rosemary; Bacsu, Chasta; Fader, Mandy; Gray, Mikel; Getliffe, Kathy; Chobanuk, Janice; Puttagunta, Lakshmi; Voaklander, Donald C
2009-01-01
Blockage of long-term indwelling catheters with mineral deposit is an ongoing management issue, but evidence on optimal management is lacking. Our purpose was to examine whether catheter washouts prevent or reduce catheter blockage. A multisite randomized controlled trial. Adults with long-term indwelling catheters that required changing every 3 weeks or less, living in the community, and requiring supportive or continuing care were recruited. Participants were randomly assigned to 1 of 3 groups: control (usual care, no washout), saline washout, or commercially available acidic washout solution (Contisol Maelor Pharmaceuticals Ltd, Wrexham, UK). At baseline visit, the catheter was changed and participants were followed weekly for 8 weeks, with checks for catheter patency and urine pH. Participants randomized to saline or commercial solution had a weekly washout with the appropriate solution. Endpoints were 8 weeks (completion data), 3 or more catheter changes in the 8-week period, or symptomatic urinary tract infection (UTI) requiring antibiotics. The study hypothesis was that catheter life would be extended by 25% in the commercial solution group. It was not possible to blind participants or research nurses to washout versus no intervention, but participants in the saline and washout solution groups were blinded to solution type. One hundred twelve potential participants were screened; 73 were enrolled, randomized, and included in the final analysis. Of these, 53 completed the full 8 weeks of data collection; 16 terminated early because of 3 catheter changes or self-reported 'UTI'. Other reasons for termination were hematuria, latex sensitivity, deceased/severe illness, or personal choice. Analysis of variance was used to analyze mean differences on demographic variables and mean number of weeks in study. Kaplan-Meier survival curve analysis showed no statistical difference between the groups in time to first catheter change. At this time, the evidence is insufficient to state whether catheter washout with saline or Contisol is more effective than usual care with no washout in preventing blocking. No increased risk of UTI was associated with washout regimes.
Kawai, Eichiro; Yaoita, Hisao; Ichinoi, Natsuko; Sakamoto, Osamu; Kure, Shigeo
2017-01-01
Kocuria kristinae is a catalase-positive, coagulase-negative, Gram-positive coccus found in the environment and in normal skin and mucosa in humans; however, it is rarely isolated from clinical specimens and is considered a nonpathogenic bacterium. We describe a case of catheter-related bacteremia due to K. kristinae in a young adult with propionic acidemia undergoing periodic hemodialysis. The patient had a central venous catheter implanted for total parenteral nutrition approximately 6 months prior to the onset of symptoms because of repeated acute pancreatitis. K. kristinae was isolated from two sets of blood cultures collected from the catheter. Vancomycin followed by cefazolin for 16 days and 5-day ethanol lock therapy successfully eradicated the K. kristinae bacteremia. Although human infections with this organism appear to be rare and are sometimes considered to result from contamination, physicians should not underestimate its significance when it is isolated in clinical specimens. PMID:28194286
Kimura, Masato; Kawai, Eichiro; Yaoita, Hisao; Ichinoi, Natsuko; Sakamoto, Osamu; Kure, Shigeo
2017-01-01
Kocuria kristinae is a catalase-positive, coagulase-negative, Gram-positive coccus found in the environment and in normal skin and mucosa in humans; however, it is rarely isolated from clinical specimens and is considered a nonpathogenic bacterium. We describe a case of catheter-related bacteremia due to K. kristinae in a young adult with propionic acidemia undergoing periodic hemodialysis. The patient had a central venous catheter implanted for total parenteral nutrition approximately 6 months prior to the onset of symptoms because of repeated acute pancreatitis. K. kristinae was isolated from two sets of blood cultures collected from the catheter. Vancomycin followed by cefazolin for 16 days and 5-day ethanol lock therapy successfully eradicated the K. kristinae bacteremia. Although human infections with this organism appear to be rare and are sometimes considered to result from contamination, physicians should not underestimate its significance when it is isolated in clinical specimens.
Lee, Ji-Young; Ko, Kwan Soo; Peck, Kyong Ran; Oh, Won Sup; Song, Jae-Hoon
2006-06-01
To investigate appropriate antimicrobial agents, the optimal concentration and treatment duration for the antibiotic lock technique (ALT) to treat catheter-related infections caused by Staphylococcus epidermidis and Staphylococcus aureus. We evaluated the bacterial killing activity of vancomycin, teicoplanin, ciprofloxacin, rifampicin, cefazolin, gentamicin, nafcillin and erythromycin against biofilms formed by two strains of S. aureus and two strains of S. epidermidis. The effectiveness of the antibiotic lock was assayed after exposure to antibiotics (1, 5 and 10 mg/mL) for 1, 3, 5, 7, 10 or 14 days using an in vitro model of biofilms on polyurethane film. The biofilms were completely sterile after exposure to vancomycin (5 mg/mL) for 5 days and teicoplanin (5 and 10 mg/mL) for 7 days. Ciprofloxacin and rifampicin (both 5 mg/mL) achieved eradication of the biofilms of both staphylococcal species more rapidly than vancomycin or teicoplanin. Significant biofilm eradication was not achieved with cefazolin, nafcillin, gentamicin and erythromycin at any of the time exposures examined. The data suggest that 5 mg/mL vancomycin, ciprofloxacin or rifampicin can eradicate S. epidermidis and S. aureus biofilms within 5 days. These findings warrant prospective clinical trials for the evaluation of the clinical efficacy of ALT for less than 10 days.
Tsai, Hsing-Chen; Huang, Li-Min; Chang, Luan-Yin; Lee, Ping-Ing; Chen, Jong-Ming; Shao, Pei-Lan; Hsueh, Po-Ren; Sheng, Wang-Huei; Chang, Yu-Ching; Lu, Chun-Yi
2015-12-01
Central line-associated bloodstream infection (CLABSI) is a serious complication in hematology-oncology patients. This study aimed to analyze the prevalence of CLABSI and the effectiveness of antimicrobial lock therapy (ALT) in pediatric patients. BSIs of all pediatric hematology-oncology patients admitted to a children's hospital between January 2009 and December 2013 were reviewed. The United States National Healthcare Safety Network and Infectious Diseases Society of America guidelines were used to define CLABSI and catheter-related BSI (CRBSI). The incidence, laboratory and microbiology characteristics, poor outcome, and effectiveness of ALT were analyzed. There were 246 cases of CLABSI in 146 patients (mean age, 10.0 years), including 66 (26.8%) cases of CRBSI. The incidence of CLABSI was 4.49/1000 catheter-days, and the infection was responsible for 32.9% of the complications these patients developed and 9.3% of contributable mortality. Patients with acute myeloid leukemia had the highest infection density (5.36/1000 patient-days). Enterobacteriaceae (40.2%) and coagulase-negative staphylococci (CoNS; 20.7%) were the predominant pathogens. In multivariate analysis, older age, male sex, elevated C-reactive protein, acute lymphoblastic leukemia, and candidemia were associated with poor outcome. The success rate of ALT was 58.6% (17/29) for the treatment of CoNS and 78.3% (29/37) for Enterobacteriaceae infections. Patients with candidemia (n = 18) had the highest mortality (33.4%) and catheter removal rate (66.7%). Chlorhexidine as the disinfectant decreased the 1-year CLABSI rate from 13.7/1000 to 8.4/1000 catheter-days (p = 0.02). CoNS and Enterobacteriaceae are the predominant pathogens in CLABSI among pediatric hematology-oncology patients. ALT is effective and showed no significant side effect. New disinfection practice and infection control measures can decrease CLABSI. Copyright © 2014. Published by Elsevier B.V.
Hemodialysis tunneled central venous catheters: five-year outcome analysis.
Mandolfo, Salvatore; Acconcia, Pasqualina; Bucci, Raffaella; Corradi, Bruno; Farina, Marco; Rizzo, Maria Antonietta; Stucchi, Andrea
2014-01-01
Tunneled central venous catheters (tCVCs) are considered inferior to arteriovenous fistulas (AVFs) and grafts in all nephrology guidelines. However, they are being increasingly used as hemodialysis vascular access. The purpose of this study was to document the natural history of tCVCs and determine the rate and type of catheter replacement. This was a prospective study of 141 patients who underwent hemodialysis with tCVCs between January 2008 and December 2012. The patients used 154 tCVCs. Standard protocols about management of tCVCs, according to European Renal Best Practice, were well established. All catheters were inserted in the internal jugular vein. Criteria for catheter removal were persistent bloodstream infection, detection of an outbreak of catheter-related bloodstream (CRBS) infections, or catheter dysfunction. Event rates were calculated per 1,000 catheter days; tCVC cumulative survival was estimated by Kaplan-Meier analysis. Catheter replacement occurred in 15 patients (0.29 per 1,000 days); catheter dysfunction was the main cause of replacement (0.18 per 1,000 days), typically within 12 months of surgical insertion. A total of 53 CRBS events in 36 patients were identified (0.82 per 1,000 days); 17 organisms, most commonly Gram-positive pathogens, were isolated; 87% of CVC infections were treated by systemic antibiotics associated with lock therapy. tCVC cumulative survival was 91% at 1 year, 88% at 2 years and 85% at 4 years. Our data show a high survival rate of tCVCs in hemodialysis patients, with low incidence of catheter dysfunction and CRBS events. These data justify tCVC use for hemodialysis vascular access, also as first choice, especially in patients with exhausted peripheral access and limited life expectancy.
2013-01-01
Central venous catheters (CVCs) are indispensable in modern pediatric medicine. CVCs provide secure vascular access, but are associated with a risk of severe complications, in particular bloodstream infection. We provide a review of the recent literature about the diagnostic and therapeutic challenges of catheter-related bloodstream infection (CRBSI) in children and its prevention. Variations in blood sampling and limitations in blood culturing interfere with accurate and timely diagnosis of CRBSI. Although novel molecular testing methods appear promising in overcoming some of the present diagnostic limitations of conventional blood sampling in children, they still need to solidly prove their accuracy and reliability in clinical practice. Standardized practices of catheter insertion and care remain the cornerstone of CRBSI prevention although their implementation in daily practice may be difficult. Technology such as CVC impregnation or catheter locking with antimicrobial substances has been shown less effective than anticipated. Despite encouraging results in CRBSI prevention among adults, the goal of zero infection in children is still not in range. More high-quality research is needed in the field of prevention, accurate and reliable diagnostic measures and effective treatment of CRBSI in children. PMID:24041298
Catheter closure of secundum atrial septal defects.
O'Laughlin, M P
1997-01-01
Catheter occlusion of atrial septal defects has its roots in the 1950s, with early devices being implanted during closed-heart surgery without cardiopulmonary bypass. For the past 20 years, various catheter-delivered devices have undergone testing and refinement. Designs have included single- and double-disk prostheses, with a variety of materials, delivery systems, and techniques. In this monograph, the history of atrial septal defect occluders and their evaluation, results, and prognoses will be outlined. The early work of King and Mills has been advanced in the forms of the Rashkind and Lock-USCI Clamshell occluders (USCI; Billerica, Mass), the "buttoned" device (custom made by E.B. Sideris), the Babic atrial septal defect occlusion system (Osypka, GmbH; Grenzach-Wyhlen, Germany), the Das-Angel Wings atrial septal defect occlusion device (Microvena Corporation; White Bear Lake, Minn), and others. The future holds promise for approved devices in the treatment of selected secundum atrial septal defects.
Central venous catheter - dressing change
... will need: Sterile gloves Cleaning solution A special sponge A special patch, called a Biopatch A clear ... around the catheter. Clean the skin with the sponge and cleaning solution. Air dry after cleaning. Place ...
Jauch, K. W.; Schregel, W.; Stanga, Z.; Bischoff, S. C.; Braß, P.; Hartl, W.; Muehlebach, S.; Pscheidl, E.; Thul, P.; Volk, O.
2009-01-01
Catheter type, access technique, and the catheter position should be selected considering to the anticipated duration of PN aiming at the lowest complication risks (infectious and non-infectious). Long-term (>7–10 days) parenteral nutrition (PN) requires central venous access whereas for PN <3 weeks percutaneously inserted catheters and for PN >3 weeks subcutaneous tunnelled catheters or port systems are appropriate. CVC (central venous catheter) should be flushed with isotonic NaCl solution before and after PN application and during CVC occlusions. Strict indications are required for central venous access placement and the catheter should be removed as soon as possible if not required any more. Blood samples should not to be taken from the CVC. If catheter infection is suspected, peripheral blood-culture samples and culture samples from each catheter lumen should be taken simultaneously. Removal of the CVC should be carried out immediately if there are pronounced signs of local infection at the insertion site and/or clinical suspicion of catheter-induced sepsis. In case PN is indicated for a short period (max. 7–10 days), a peripheral venous access can be used if no hyperosmolar solutions (>800 mosm/L) or solutions with a high titration acidity or alkalinity are used. A peripheral venous catheter (PVC) can remain in situ for as long as it is clinically required unless there are signs of inflammation at the insertion site. PMID:20049083
Chaves, Fernando; Garnacho-Montero, José; Del Pozo, José Luis; Bouza, Emilio; Capdevila, José Antonio; de Cueto, Marina; Domínguez, M Ángeles; Esteban, Jaime; Fernández-Hidalgo, Nuria; Fernández Sampedro, Marta; Fortún, Jesús; Guembe, María; Lorente, Leonardo; Paño, Jose Ramón; Ramírez, Paula; Salavert, Miguel; Sánchez, Miguel; Vallés, Jordi
2018-02-01
Catheter-related bloodstream infections (CRBSI) constitute an important cause of hospital-acquired infection associated with morbidity, mortality, and cost. The aim of these guidelines is to provide updated recommendations for the diagnosis and management of CRBSI in adults. Prevention of CRBSI is excluded. Experts in the field were designated by the two participating Societies (Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica and the Sociedad Española de Medicina Intensiva, Crítica y Unidades Coronarias). Short-term peripheral venous catheters, non-tunneled and long-term central venous catheters, tunneled catheters and hemodialysis catheters are covered by these guidelines. The panel identified 39 key topics that were formulated in accordance with the PICO format. The strength of the recommendations and quality of the evidence were graded in accordance with ESCMID guidelines. Recommendations are made for the diagnosis of CRBSI with and without catheter removal and of tunnel infection. The document establishes the clinical situations in which a conservative diagnosis of CRBSI (diagnosis without catheter removal) is feasible. Recommendations are also made regarding empirical therapy, pathogen-specific treatment (coagulase-negative staphylococci, Sthaphylococcus aureus, Enterococcus spp, Gram-negative bacilli, and Candida spp), antibiotic lock therapy, diagnosis and management of suppurative thrombophlebitis and local complications. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.
Klumpner, Thomas T; Lange, Elizabeth M S; Ahmed, Heena S; Fitzgerald, Paul C; Wong, Cynthia A; Toledo, Paloma
2016-11-01
Programmed intermittent bolus injection of epidural anesthetic solution results in decreased anesthetic consumption and better patient satisfaction compared with continuous infusion, presumably by better spread of the anesthetic solution in the epidural space. It is not known whether the delivery speed of the bolus injection influences analgesia outcomes. The objective of this in vitro study was to determine the pressure generated by a programmed intermittent bolus pump at 4 infusion delivery speeds through open-ended, single-orifice and closed-end, multiorifice epidural catheters. In vitro observational study. Not applicable. Not applicable. A CADD-Solis Pain Management System v3.0 with Programmed Intermittent Bolus Model 2110 was connected via a 3-way adapter to an epidural catheter and a digital pressure transducer. Pressures generated by delivery speeds of 100, 175, 300, and 400 mL/h of saline solution were tested with 4 epidural catheters (2 single orifice and 2 multiorifice). These runs were replicated on 5 pumps. Analysis of variance was used to compare the mean peak pressures of each delivery speed within each catheter group (single orifice and multiorifice). Thirty runs at each delivery speed were performed with each type of catheter for a total of 240 experimental runs. Peak pressure increased with increasing delivery speeds in both catheter groups (P<.001). Peak pressures were higher with the multiorifice catheter compared with the single-orifice catheter at all delivery speeds (P<.001, for all). Using a pump designed for programmed intermittent infusion boluses, the delivery speed of saline solution through epidural catheters was directly related to the peak pressures. Future work should evaluate whether differences in the delivery speed of anesthetic solution into the epidural space correlate with differences in the duration and quality of analgesia during programmed intermittent epidural bolus delivery. Copyright © 2016 Elsevier Inc. All rights reserved.
Phase-locked patterns of the Kuramoto model on 3-regular graphs
NASA Astrophysics Data System (ADS)
DeVille, Lee; Ermentrout, Bard
2016-09-01
We consider the existence of non-synchronized fixed points to the Kuramoto model defined on sparse networks: specifically, networks where each vertex has degree exactly three. We show that "most" such networks support multiple attracting phase-locked solutions that are not synchronized and study the depth and width of the basins of attraction of these phase-locked solutions. We also show that it is common in "large enough" graphs to find phase-locked solutions where one or more of the links have angle difference greater than π/2.
Phase-locked patterns of the Kuramoto model on 3-regular graphs.
DeVille, Lee; Ermentrout, Bard
2016-09-01
We consider the existence of non-synchronized fixed points to the Kuramoto model defined on sparse networks: specifically, networks where each vertex has degree exactly three. We show that "most" such networks support multiple attracting phase-locked solutions that are not synchronized and study the depth and width of the basins of attraction of these phase-locked solutions. We also show that it is common in "large enough" graphs to find phase-locked solutions where one or more of the links have angle difference greater than π/2.
2013-02-13
Chronic Myeloproliferative Disorders; Infection; Leukemia; Lymphoma; Lymphoproliferative Disorder; Multiple Myeloma and Plasma Cell Neoplasm; Myelodysplastic Syndromes; Myelodysplastic/Myeloproliferative Neoplasms; Unspecified Adult Solid Tumor, Protocol Specific
Yokoyama, H; Aoyama, T; Matsuyama, T; Yamamura, Y; Nakajima, K; Nakamura, K; Sato, H; Kotaki, H; Chiba, S; Hirai, H; Yazaki, Y; Iga, T
1998-12-01
We studied the cause of cracking of a clinically used polyurethane (PU) catheter during the constant infusion of etoposide (VP-16) injection (Lastet), administered without dilution to patients as a part of combination high-dose chemotherapy. After VP-16 injection was infused into the PU catheter at a constant infusion rate (30 ml/h) for 24 h, a decrease in the elasticity (36% of untreated) and on increase in the length of the catheter (3.7%) were observed. These changes were significantly higher than those treated with the control saline. The similar changes of the PU catheter were observed after treatment with a basal solution containing polyethylene glycol 400 (PEG 400), polysorbate 80 and ethanol, which is the vehicle of the VP-16 injection, and with ethanol alone. Moreover, obvious degeneration of the internal wall (occurrence of spots like melting) and cutting face (micro-cracking) of the catheter was observed with an electron microscope after treatment with the vehicle. On the other hand, the elasticity or extension of the PU catheter were not changed after treatment with saline or PEG 400. From these findings, it was suggested that the degeneration and subsequent cracking of the PU catheter during the infusion of VP-16 injection was caused by ethanol contained in its injection solution. No cracking or morphological changes of polyvinyl chloride (PVC) and silicone catheters were found after treatment with the vehicle solution. However, since it has been reported in previous reports that di(2-ethylhexyl)phthalate was leached from PVC bags, the high dose chemotherapy with the dilution-free VP-16 injection should be achieved safely and effectively using a silicon catheter, rather than the PU catheter.
Pohl, Fabian; Hartmann, Werner; Holzmann, Thomas; Gensicke, Sandra; Kölbl, Oliver; Hautmann, Matthias G
2014-01-25
Many cancer patients receive a central venous catheter or port system prior to therapy to assure correct drug administration. Even appropriate hygienic intervention maintenance carries the risk of contaminating the middle port (C-port) of a three-way cock (TWC), a risk that increases with the number of medical interventions. Because of the complexity of the cleaning procedure with disconnection and reconnection of the standard luer lock cap (referred as "intervention"), we compared luer lock caps with a "closed access system" consisting of a luer access split septum system with regard to process optimization (work simplification, process time), efficiency (costs) and hygiene (patient safety). For determination of process optimization the workflow of an intervention according to the usual practice and risks was depicted in a process diagram. For determining the actual process costs, we analyzed use of material and time parameters per intervention and used the process parameters for programming the process into a simulation run (n = 1000) to determine the process costs as well as their differences (ACTUAL vs. NOMINAL) within the framework of a discrete event simulation.Additionally cultures were carried out at the TWC C-ports to evaluate possible contamination. With the closed access system, the mean working time of 5.5 minutes could be reduced to 2.97 minutes. The results for average process costs (labour and material costs per use) were 3.92 € for luer lock caps and 2.55 € for the closed access system. The hypothesis test (2-sample t-test, CI 0.95, p-value<0.05) confirmed the significance of the result.In 50 reviewed samples (TWC's), the contamination rate for the luer lock cap was 8% (4 out of 50 samples were positive), the contamination rate of the 50 samples with the closed access system was 0%.Possible hygienic risks (related to material, surroundings, staff handling) could be reduced by 65.38%. In the present research, the closed access system with a divided split septum was superior to conventional luer lock caps. The advantage of the closed access system lies in the simplified handling for staff, which results in a reduced risk of patient infection due to improved clinical hygiene.
Minosio, J P; Bourget, P; Clapeau, G; Rieutord, A; Hamon, M
1994-01-01
Recourse to sounding with vein catheters is more and more frequent in hospital environments. At the same time, a perceptible increase in incidents and accidents linked to this constantly growing practice is noted. The multiplication of new biomaterials used in the composition of catheters leads to taking into account the criteria of innocuousness and physiochemical inertia as discriminant elements in the choice of biomaterials. A study in vitro has been undertaken of the interaction between short catheters made of ethylenetetrafluoroethylen (ETFE) and antibiotic solutions widely used in hospital environments. The confrontation concerned solutions of vancomycine (Vancocin), ciprofloxacine (Ciflox) and the amoxicillin-clavulanic acid (Augmentin) association. A device has been fitted up and operative conditions have been set in order that the flushing out of the catheters by the solutions be in quality and quantity, as near as possible to actual conditions of use. The interaction marked chosen being a possible release of fluorides ions by the polymer, the determination of this anion has been made by liquid-gas chromatography paired with a flame ionization detection. We show the inertia of ETFE catheters with respect to the solutions examined. Taking into account the initially defined objectives, the conclusion of the work is important and constitutes a considerable factor of security for the catheters user whether he be buyer or practitioner. The model of study making up this approach could very be applied to other categories of materials and therapeutics.
Wolf, Joshua; Allison, Kim J; Tang, Li; Sun, Yilun; Hayden, Randall T; Flynn, Patricia M
2014-10-01
Long-term central venous catheters (CVCs) are essential to modern pediatric oncology practice, but central line-related bloodstream infection (CRBSI) is a frequent and important complication. CVC salvage is often attempted but treatment failure is common due to persistent infection, delayed catheter removal, or subsequent relapse of infection, which can be associated with significant morbidity and cost. Adjunctive antibiotic lock therapy (ALT) has been proposed to reduce the risk of treatment failure, but insufficient data are available to confirm efficacy of this intervention. We undertook a retrospective matched cohort study of ALT use for treatment of CRBSI in pediatric hematology/oncology patients at St. Jude Children's Research Hospital between 2006 and 2012. Thirty-eight eligible episodes of CRBSI treated with adjunctive ALT were identified and compared to 73 episodes treated with standard therapy (ST) alone, matched by catheter-type and organism. Overall, treatment failure was similar between ALT and ST groups (50.0 vs. 38.4%; P = 0.24), but the timing was different; in the ALT cohort, immediate CVC removal was less common (0.0 vs. 12.3%; P = 0.03) but delayed removal (4-13 days) and relapse of infection was more common (50.0 vs. 24.7%; P = 0.01). This retrospective study was unable to identify any benefit of adjunctive ALT in pediatric oncology patients with CRBSI. The available evidence does not support routine ALT use, and well-conducted prospective studies are needed. © 2014 Wiley Periodicals, Inc.
Fox-Alvarez, W Alexander; Case, J Brad; Cooke, Kirsten L; Garcia-Pereira, Fernando L; Buckley, Gareth J; Monnet, Eric; Toskich, Beau B
2016-07-01
OBJECTIVE To evaluate a percutaneous, continuous gastric decompression technique for dogs involving a temporary T-fastener gastropexy and self-retaining decompression catheter. ANIMALS 6 healthy male large-breed dogs. PROCEDURES Dogs were anesthetized and positioned in dorsal recumbency with slight left-lateral obliquity. The gastric lumen was insufflated endoscopically until tympany was evident. Three T-fasteners were placed percutaneously into the gastric lumen via the right lateral aspect of the abdomen, caudal to the 13th rib and lateral to the rectus abdominis muscle. Through the center of the T-fasteners, a 5F locking pigtail catheter was inserted into the gastric lumen and attached to a device measuring gas outflow and intragastric pressure. The stomach was insufflated to 23 mm Hg, air was allowed to passively drain from the catheter until intraluminal pressure reached 5 mm Hg for 3 cycles, and the catheter was removed. Dogs were hospitalized and monitored for 72 hours. RESULTS Mean ± SD catheter placement time was 3.3 ± 0.5 minutes. Mean intervals from catheter placement to a ≥ 50% decrease in intragastric pressure and to ≤ 6 mm Hg were 2.1 ± 1.3 minutes and 8.4 ± 5.1 minutes, respectively. After catheter removal, no gas or fluid leakage at the catheter site was visible laparoscopically or endoscopically. All dogs were clinically normal 72 hours after surgery. CONCLUSIONS AND CLINICAL RELEVANCE The described technique was performed rapidly and provided continuous gastric decompression with no evidence of postoperative leakage in healthy dogs. Investigation is warranted to evaluate its effectiveness in dogs with gastric dilatation-volvulus.
Maisetta, Giuseppantonio; Grassi, Lucia; Di Luca, Mariagrazia; Bombardelli, Silvia; Medici, Chiara; Brancatisano, Franca Lisa; Esin, Semih; Batoni, Giovanna
2016-08-01
In search of new antimicrobials with anti-biofilm potential, in the present study activity of the frog-skin derived antimicrobial peptide temporin 1Tb (TB) against Staphylococcus epidermidis biofilms was investigated. A striking ability of TB to kill both forming and mature S. epidermidis biofilms was observed, especially when the peptide was combined with cysteine or EDTA, respectively. Kinetics studies demonstrated that the combination TB/EDTA was active against mature biofilms already after 2-4-h exposure. A double 4-h exposure of biofilms to TB/EDTA further increased the therapeutic potential of the same combination. Of note, TB/EDTA was able to eradicate S. epidermidis biofilms formed in vitro on silicone catheters. At eradicating concentrations, TB/EDTA did not cause hemolysis of human erythrocytes. The results shed light on the anti-biofilm properties of TB and suggest a possible application of the peptide in the lock therapy of catheters infected with S. epidermidis.
Electronic and elastic mode locking in charge density wave conductors
NASA Astrophysics Data System (ADS)
Zettl, A.
1986-12-01
Mode locking phenomena are investigated in the charge density wave (CDW) materials NbSe 3 and TaS 3. The joint application of ac and dc electric fields results in free running and mode locked solutions for the CDW drift velocity, with associated ac-induced dynamic coherence lengths ξ D(ac) on the order of several hundred microns. The electronic response couples directly to the elastic properties of the crystal, with corresponding free running and mode locked solutions for the velocity of sound. Phase slip center-induced discontinuities in the CDW phase velocity lead to mode locked solutions with period doubling routes to chaos, and noisy precursor effects at bifurcation points. These results are discussed in terms of simple models of CDW domain synchronization, and internal CDW dynamics.
Zhang, Yunhui; Fu, Yakun; Yu, Jialin; Ai, Qing; Li, Junshuai; Peng, Ningning; Song, Sijie; He, Yu; Wang, Zhengli
2015-11-01
Central venous catheters are widely used in neonatal intensive care units (NICUs) nowadays. The commonest cause of catheter-related bloodstream infections (CRBSIs) is coagulase-negative staphylococci (CoNS). Ambroxol, an active metabolite of bromhexine, exhibits antimicrobial activity against strains producing biofilm and enhances the bactericidal effect of some antibiotic by breaking the structure of biofilm. In this study, we aimed to determine the effect of ambroxol with vancomycin on the biofilm of Staphylococcus epidermidis (S. epidermidis) in vitro and in vivo. In the in vitro study, the biofilm of S. epidermidis was assessed by XTT reduction assay and analysed by confocal laser scanning microscopy (CLSM). In the in vivo study, a rabbit model of CRBSIs was created by intravenous intubation with a tube covered with S. epidermidis biofilm. The rabbits received one of the following four treatments by means of antibiotic lock therapy: normal heparin, ambroxol, vancomycin, or vancomycin plus ambroxol each for 3 days. The microstructure of the biofilm was assessed by scanning electron microscopy (SEM). The number of bacterial colonies in the organs (liver, heart, and kidney) and on the intravenous tubes was measured on agar plates. Pathological changes in the organs (liver, heart, and kidney) were observed with Hematoxylin-Eosin staining. The ambroxol exhibits significant efficacy to potentiate the bactericidal effect of vancomycin on S. epidermidis biofilm both in vitro and in vivo. The antibiotic lock therapy using a combination of ambroxol and vancomycin reveals a high ability to eradicate S. epidermidis biofilms in vivo. These results provide the basis of a useful anti-infection strategy for the treatment of CRBSIs. Copyright © 2015 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Electrical stimulation of the epidural space using a catheter with a removable stylet.
Charghi, Roshanak; Chan, Sher Yi; Kardash, Kenneth J; Finlayson, Roderick J; Tran, De Q H
2007-01-01
Electrical stimulation can be used to verify the location of epidural catheters. With the traditional technique, the latter must be primed with saline to allow for electrical conduction: any air lock will, thus, hinder the flow of current. Therefore, we set out to explore an alternative mode of stimulation by use of a catheter containing a removable stylet. This study examines the reliability of this new technique. In 71 patients undergoing surgery, a thoracic epidural catheter was inserted preoperatively. Loss of resistance was used to identify the epidural space. The TheraCath was introduced 5 cm into the space and connected to a neurostimulator via a 2-headed alligator clip. The intensity, pulse width, and level of myotomal contractions were recorded upon stimulation of the epidural space. A bolus of lidocaine was then injected and the patient assessed for sensory block to ice. The failure rate in proper epidural catheter placement was 8.5%. Epidural stimulation yielded a mean threshold of 1.90 +/- 1.80 nanocoulombs. A total of 37 catheters produced a unilateral muscular response; however, block to ice was bilateral. When compared with the ice test, the sensitivity, specificity, positive predictive value, and negative predictive value of epidural stimulation with the TheraCath were 92%, 83%, 98%, and 50%, respectively. We conclude that the TheraCath, because of the removable stylet, provides effective electrostimulation of the epidural space. Its use was simple and devoid of complications. Nonetheless, further studies are required before implementing its routine use in clinical settings.
Witkowski, Maria Carolina; de Moraes, Maria Antonieta P.; Firpo, Cora Maria F.
2013-01-01
OBJECTIVE: To compare two systems of arterial catheters maintenance in postoperative pediatric surgery using intermittent or continuous infusion of heparin solution and to analyze adverse events related to the site of catheter insertion and the volume of infused heparin solution. METHODS: Randomized control trial with 140 patients selected for continuous infusion group (CIG) and intermittent infusion group (IIG). The variables analyzed were: type of heart disease, permanence time and size of the catheter, insertion site, technique used, volume of heparin solution and adverse events. The descriptive variables were analyzed by Student's t-test and the categorical variables, by chi-square test, being significant p<0.05. RESULTS: The median age was 11 (0-22) months, and 77 (55%) were females. No significant differences between studied variables were found, except for the volume used in CIG (12.0±1.2mL/24 hours) when compared to IIG (5.3±3.5mL/24 hours) with p<0.0003. CONCLUSIONS: The continuous infusion system and the intermittent infusion of heparin solution can be used for intra-arterial catheters maintenance in postoperative pediatric surgery, regardless of patient's clinical and demographic characteristics. Adverse events up to the third postoperative day occurred similarly in both groups. However, the intermittent infusion system usage in underweight children should be considered, due to the lower volume of infused heparin solution [ClinicalTrials.gov Identifier: NCT01097031]. PMID:24473958
A simple solution for complicated pleural effusions.
Murthy, Sudish C; Okereke, Ikenna; Mason, David P; Rice, Thomas W
2006-09-01
Complicated pleural effusions are difficult to manage with conventional strategies. In this study, we review the safety, efficacy, and durability of PleurX catheters (Denver Biomedical, Golden, CO) for managing complicated pleural effusions and describe a patient population who might benefit. From July 1999 to February 2003, 63 PleurX catheters were placed in 58 symptomatic patients (an additional five had bilateral catheters) to manage complicated pleural effusions. Patients selected for catheter placement tended to have poor performance status (Eastern Cooperative Oncology Group < or =2) or had failed standard therapies. Of the 63 catheters, 52 (83%) were placed because of malignant complicated pleural effusions. A registry of patients was constructed, and data were obtained from review of medical records. Nonparametric estimates of freedom from reintervention and overall survival were obtained by the Kaplan-Meier method. Catheter-related complications were noted in four of 58 patients (7%) and included one each of pneumothorax, seroma, empyema, and pain syndrome. Freedom from reintervention for effusion management was 95%. Of the patients, 86% (50 of 58) experienced dyspnea relief. There were no procedure-related mortalities. Catheters remained functional up to 330 days, and four of 63 (6%) required one-time thrombolysis with tissue plasminogen activator. PleurX catheters are safe, effective, and durable solutions for complicated pleural effusions and seem to provide an attractive alternative for patients who have few other palliative options. We consider the catheters as first-line therapy for these patients.
Meng, Lina; Nguyen, Cherwyn M; Patel, Samit; Mlynash, Michael; Caulfield, Anna Finley
2018-03-01
One institution's experience with use of peripheral i.v. (PIV) catheters for prolonged infusions of 3% sodium chloride injection at rates up to 100 mL/hr is described. A prospective, observational, 13-month quality assurance project was conducted at an academic medical center to evaluate frequencies of patient and catheter phlebitis among adult inpatients who received both an infusion of 3% sodium chloride injection for a period of ≥4 hours through a dedicated PIV catheter and infusions of routine-care solutions (RCSs) through separate PIV catheters during the same hospital stay. Sixty patients received PIV infusions through a total of 291 catheters during the study period. The majority of patients (78%) received infusions of 3% sodium chloride injection for intracranial hypertension, with 30% receiving such infusions in the intensive care unit. Phlebitis occurred in 28 patients (47%) during infusions of 3% sodium chloride and 26 patients (43%) during RCS infusions ( p = 0.19). Catheter phlebitis occurred in 73 catheters (25%), with no significant difference in the frequencies of catheter phlebitis with infusion of 3% sodium chloride versus RCSs (30% [32 of 106 catheters]) versus 22% [41 of 185 catheters]), p = 0.16). Patient and catheter phlebitis rates were not significantly different with infusions of 3% sodium chloride injection versus RCSs, suggesting that an osmolarity cutoff value of 900 mOsm/L for peripheral infusions of hypertonic saline solutions may not be warranted. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Heparin or 0.9% sodium chloride to maintain central venous catheter patency: a randomized trial.
Schallom, Marilyn E; Prentice, Donna; Sona, Carrie; Micek, Scott T; Skrupky, Lee P
2012-06-01
To compare heparin (3 mL, 10 units/mL) and 0.9% sodium chloride (NaCl, 10 mL) flush solutions with respect to central venous catheter lumen patency. Single-center, randomized, open label trial. Medical intensive care unit and Surgical/Burn/Trauma intensive care unit at Barnes-Jewish Hospital, St. Louis, MO. Three hundred forty-one patients with multilumen central venous catheters. Patients with at least one lumen with a minimum of two flushes were included in the analysis. Patients were randomly assigned within 12 hrs of central venous catheter insertion to receive either heparin or 0.9% sodium chloride flush. The primary outcome was lumen nonpatency. Secondary outcomes included the rates of loss of blood return, inability to infuse or flush through the lumen (flush failure), heparin-induced thrombocytopenia, and catheter-related blood stream infection. Assessment for patency was performed every 8 hrs in lumens without continuous infusions for the duration of catheter placement or discharge from intensive care unit. Three hundred twenty-six central venous catheters were studied yielding 709 lumens for analysis. The nonpatency rate was 3.8% in the heparin group (n = 314) and 6.3% in the 0.9% sodium chloride group (n = 395) (relative risk 1.66, 95% confidence interval 0.86-3.22, p = .136). The Kaplan-Meier analysis for time to first patency loss was not significantly different (log rank = 0.093) between groups. The rates of loss of blood return and flush failure were similar between the heparin and 0.9% sodium chloride groups. Pressure-injectable central venous catheters had significantly greater rates of nonpatency (10.6% vs. 4.3%, p = .001) and loss of blood return (37.0% vs. 18.8%, p <.001) compared to nonpressure-injectable catheters. The frequencies of heparin-induced thrombocytopenia and catheter-related blood stream infection were similar between groups. 0.9% sodium chloride and heparin flushing solutions have similar rates of lumen nonpatency. Given potential safety concerns with the use of heparin, 0.9% sodium chloride may be the preferred flushing solution for short-term use central venous catheter maintenance.
Matonhodze, Baron B; Hofmeyr, G Justus; Levin, Jonathan
2003-05-01
To compare three methods of labour induction. Randomised controlled trial. Academic hospitals in Johannesburg, South Africa. Women with intact membranes due for induction of labour. Randomised, sealed opaque envelopes were used to allocate women to labour induction with extra-amniotic Foley catheter/titrated oral misoprostol solution (N = 174), titrated oral misoprostol solution alone (N = 176), or vaginal dinoprostone (N = 176). Misoprostol was dissolved in water and 20-40 g was given 2-hourly. These were failure to deliver vaginally within 24 hours, additional measures for induction or augmentation of labour, analgesia, and maternal and fetal complications. In the Foley catheter group, misoprostol was required in all but 1 case. Failure to deliver vaginally within 24 hours was similar for the three groups (79/174 v. 70/176 v. 70/176 respectively). Labour augmentation, caesarean section and instrumental delivery were used somewhat more frequently in the Foley/misoprostol group than in the misoprostol alone group, but these differences were not statistically significant. More analgesia was used in the Foley catheter/misoprostol group than in the misoprostol group (64/172 v. 46/175). Side-effects and neonatal complications were similar for the three groups. Use of extra-amniotic Foley catheter placement showed no measurable benefits over the use of oral misoprostol alone, or vaginal dinoprostone.
Evaluation of Disinfection Techniques for, and Their Effects on, Rectal Thermocouple Catheters1
Maher, J. T.; Rogers, M. R.; Peterson, D. W.
1961-01-01
The antibacterial activities of an iodophor (Wescodyne G), a quaternary ammonium compound (Roccal), and an iodine tincture as agents for the cold disinfection of rectal catheters contaminated in vitro were determined. Following thorough cleaning with an alcoholic solution of soft soap, each of the three disinfectants tested showed satisfactory results (100% kill) in 5 min against the enteric test bacteria (Escherichia coli and Salmonella typhosa) as well as a test species of the genus Pseudomonas, among the bacteria most resistant to surface-active agents. An aqueous solution of Wescodyne G containing 75 ppm available iodine was used both as a wiping solution and for subsequent disinfection of rectal catheters contaminated in vivo. Total bacterial destruction was found to follow a 60-min soak preceded by the wiping procedure. Rectal catheters subjected to prolonged immersion in each of the test disinfectants were found to be essentially unaffected, retaining their initial calibrations within a permissible tolerance. Neither Roccal nor Wescodyne G solutions were found to measurably attack bare thermocouples. Alcoholic iodine 0.5% did, however, exert a deteriorating effect on bare thermocouples in a short time, as measured by change in resistance characteristics. The results of this study have led to the recommendation that Wescodyne G containing 75 ppm available iodine be used in standing operating procedures for the initial cleaning and subsequent disinfection of rectal thermocouple catheters. Images Fig. 1 PMID:13765378
Central line-associated bloodstream infection in childhood malignancy: Single-center experience.
Miliaraki, Marianna; Katzilakis, Nikolaos; Chranioti, Ioanna; Stratigaki, Maria; Koutsaki, Maria; Psarrou, Maria; Athanasopoulos, Emmanouil; Stiakaki, Eftichia
2017-07-01
Central line-associated bloodstream infection (CLABSI) is a common complication in children with malignancy, often leading to prolonged hospitalization, delay in chemotherapy or catheter removal. This retrospective epidemiological study reviewed 91 children with malignancy over a 5 year period between 2011 and 2015 and analyzed potential risk factors for CLABSI. Symptoms, laboratory and microbiology characteristics, subsequent treatment and outcome were recorded and analyzed. All the collected data were processed through SPSS for statistical analysis. Among 40 episodes of CLABSI recorded in 30 patients, the rate of CLABSI was estimated as 2.62 episodes per 1,000 days of central venous catheter (CVC) carriage. Most of the bacterial pathogens isolated in CLABSI episodes were Gram positive, including different strains of staphylococci, while Gram-negative bacteria were involved in 30% of episodes. Invasive mycosis was isolated in 7.5% of episodes, accounting for the highest catheter removal rate. Intensive chemotherapy and prolonged hospitalization proved to be independent risk factors for CVC infection. In children with neutropenia, the risk for CLABSI was also fourfold greater (P = 0.001). Children with leukemia had a fivefold greater risk for CLABSI (P = 0.005). Finally, although 36% of patients received antibiotic lock therapy, in 15% of these patients catheter replacement could not be avoided due to persistent serious infection. Younger age, neutropenia, hematologic malignancy and longer catheterization are important risk factors for CLABSI, but further research is required for the prevention of catheter-related infection in children with malignancy. © 2017 Japan Pediatric Society.
Sayet, G; Sinegre, M; Ben Reguiga, M
2014-01-01
Antibiotic Lock technique maintains catheters' sterility in high-risk patients with long-term parenteral nutrition. In our institution, vancomycin, teicoplanin, amikacin and gentamicin locks are prepared in the pharmaceutical department. In order to insure patient safety and to comply to regulatory requirements, antibiotic locks are submitted to qualitative and quantitative assays prior to their release. The aim of this study was to develop an alternative quantitation technique for each of these 4 antibiotics, using a Fourier transform infrared (FTIR) coupled to UV-Visible spectroscopy and to compare results to HPLC or Immunochemistry assays. Prevalidation studies permitted to assess spectroscopic conditions used for antibiotic locks quantitation: FTIR/UV combinations were used for amikacin (1091-1115cm(-1) and 208-224nm), vancomycin (1222-1240cm(-1) and 276-280nm), and teicoplanin (1226-1230cm(-1) and 278-282nm). Gentamicin was quantified with FTIR only (1045-1169cm(-1) and 2715-2850cm(-1)) due to interferences in UV domain of parabens, preservatives present in the commercial brand used to prepare locks. For all AL, the method was linear (R(2)=0.996 to 0.999), accurate, repeatable (intraday RSD%: from 2.9 to 7.1% and inter-days RSD%: 2.9 to 5.1%) and precise. Compared to the reference methods, the FTIR/UV method appeared tightly correlated (Pearson factor: 97.4 to 99.9%) and did not show significant difference in recovery determinations. We developed a new simple reliable analysis technique for antibiotics quantitation in locks using an original association of FTIR and UV analysis, allowing a short time analysis to identify and quantify the studied antibiotics. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Wang, Rui; Luo, Ou; He, Liu; Li, Jia-Xin; Zhang, Ming-Guang
2012-11-01
In Mainland China, heparin saline solution is commonly used for flushing and locking peripheral intravenous access devices in clinical practice for a long time. We conducted a prospective controlled trial to compare the effectiveness and safety of preservative-free 0.9% sodium chloride solution versus heparin saline solution as flushing and locking solution for peripheral intravenous access devices. Patients with gastroenterological or hepatic diseases were enrolled for this study from August 2011 to October 2011. After non-randomized allocation, preservative-free 0.9% sodium chloride was used as flushing and locking solution in the sodium chloride solution group, while hepatic solution (10 U/mL) was given in the heparin saline solution group. The device related complications and its maintenance duration were compared between two groups. One-way ANOVA, Chi(2), or Mantel-Haenszel test were performed using SPSS 13.0 and RevMan 5.0. Totally, 181 and 178 peripheral intravenous access devices in the sodium chloride solution and heparin saline solution groups were included and analyzed. Results indicated than sodium chloride solution did not increase the risks of occlusion (7.7% vs. 7.9%) and other adverse events of peripheral intravenous access devices (P = 0.163). Sodium chloride solution neither shortened the duration of peripheral intravenous access devices maintenance (3.6 ± 1.1 days vs. 3.7 ± 1.2 days, P = 0.651), nor increased the proportion of abnormal withdrawal (29.3% vs. 31.5%, P = 0.654). Sodium chloride solution is as effective and safe as conventional heparin saline solution for flushing and locking peripheral intravenous access devices, which results from our evidence-based study and should be transferred to other nurses in China. © 2012 Wiley Publishing Asia Pty Ltd and Chinese Cochrane Center, West China Hospital of Sichuan University.
Washout policies in long-term indwelling urinary catheterisation in adults.
Hagen, Suzanne; Sinclair, Lesley; Cross, Stephen
2010-03-17
People requiring long-term bladder draining with an indwelling catheter can experience catheter blockage. Regimens involving different solutions can be used to washout catheters with the aim of preventing blockage. To determine if certain washout regimens are better than others in terms of effectiveness, acceptability, complications, quality of life and economics for the management of long-term indwelling urinary catheterisation in adults. We searched the Cochrane Incontinence Group Specialised Trials Register, MEDLINE, MEDLINE In-Process & Other Non-Indexed Citations, CINAHL and EMBASE (searches last updated April 2009). Additionally, we examined all reference lists of identified trials. All randomised and quasi-randomised trials comparing catheter washout policies (e.g. washout versus no washout, different washout solutions, frequency, duration, volume, concentration, method of administration) in adults (16 years and above) in any setting (i.e. hospital, nursing/residential home, community) with an indwelling urethral or suprapubic catheter for more than 28 days. Data were extracted by three reviewers independently and compared. Disagreements were resolved by discussion. Data were processed as described in the Cochrane Handbook. If the data in trials were not fully reported, clarification was sought from the authors. For categorical outcomes, the numbers reporting an outcome were related to the numbers at risk in each group to derive an risk ratio (RR). For continuous outcomes, means and standard deviations were used to derive weighted mean differences (WMD). No meta-analysis of study results was possible. Five trials met the inclusion criteria involving 242 patients (132 completed) in two cross-over and three parallel-group randomised controlled trials. Only three of the eight pre-stated comparisons were addressed in these trials. Some trials addressed more than one comparison (e.g. washout versus no washout and one type of washout solution versus another). The analyses reported for the two cross-over trials were inappropriate as they were based on differences between groups rather than differences within individuals receiving sequential interventions. Two parallel-group trials had limited value: one combined results for suprapubic and urethral catheters and one had data on only four participants. Only one trial was free of significant methodological limitations, but its sample size was small.Three trials compared no washout with one or more washout solution (saline or acidic solutions) and authors tended to conclude no difference in clinical outcomes between washout and no washout. In the one trial which had data of sufficient quality to allow interpretation, no difference was detected between washout and no washout groups in the rate of symptomatic urinary tract infection or time to first catheter change. Three trials compared different types of solution: saline versus acidic solutions (two trials); saline versus acidic solution versus antibiotic solution (one trial). Authors tended to report no difference between different washout solutions but the data were too few to support their conclusions. The one trial which warranted consideration concluded no difference between saline and an acidic solution in terms of symptomatic urinary tract infections or time to first catheter change. The data from five trials comparing differing washout policies were sparse and trials were generally of poor quality or poorly reported. The evidence was too scanty to conclude whether or not washouts were beneficial. In the first instance we require further rigorous, high quality trials with adequate power to detect any benefit from washout being performed as opposed to none. Then trials comparing different washout solutions, washout volumes, frequencies/timings and routes of administration are needed.
Sinclair, Lesley; Hagen, Suzanne; Cross, Stephen
2011-09-01
People requiring long-term bladder draining with an indwelling catheter can experience catheter blockage. Regimens involving different solutions can be used to wash out catheters with the aim of preventing blockage. To determine if certain washout regimens (including no washout) are better than others in terms of effectiveness, acceptability, complications, quality of life, and economics for the management of long-term indwelling urinary catheters in adults. We searched the Cochrane Incontinence Group Specialized Trials Register (searched April 30, 2009), MEDLINE (January 1966 to April 2009), MEDLINE In-Process (April 30, 2009), EMBASE (January 1980 to April 2009), and CINAHL (December 1981 to April 2009). Additionally, we examined all reference lists of identified trials and contacted manufacturers and researchers in the field. All randomized and quasi-randomized trials comparing catheter washout policies (e.g., washout vs. no washout, different washout solutions, frequency, duration, volume, concentration, method of administration) in adults (16 years and above) in any setting (i.e., hospital, nursing/residential home, community) with an indwelling urethral or suprapubic catheter in place for more than 28 days. Data were extracted by three reviewers independently and compared. Disagreements were resolved by discussion. Data were processed as described in the Cochrane Handbook. If the trial data were not fully reported, clarification was sought from the authors. For categorical outcomes, the numbers reporting an outcome were related to the numbers at risk in each group to derive a risk ratio (RR). For continuous outcomes, means, and standard deviations were used to derive weighted mean differences (WMD). No meta-analysis of study results was possible. Five trials met the inclusion criteria involving 242 patients (132 completed) in two cross-over and three parallel-group randomized controlled trials. Only three of the eight comparisons pre-stated in the review protocol were addressed in these trials. Some trials addressed more than one comparison (e.g., washout vs. no washout and one type of washout solution vs. another). The analyses reported for the two cross-over trials were inappropriate as they were based on differences between groups rather than differences within individuals receiving sequential interventions. Two parallel-group trials had limited value: one combined results for suprapubic and urethral catheters and one had data on only four participants. Only one trial was free of significant methodological limitations, but its sample size was small. Three trials compared no washout with one or more washout solution (saline or acidic solutions) and authors tended to conclude no difference in clinical outcomes between washout and no washout. In the one trial which had data of sufficient quality to allow interpretation, no difference was detected between washout and no washout groups in the rate of symptomatic urinary tract infection or time to first catheter change. Three trials compared different types of solution: saline versus acidic solutions (two trials); saline versus acidic solution versus antibiotic solution (one trial). Authors tended to report no difference between different washout solutions but the data were too few to support their conclusions. The one trial which warranted consideration concluded no difference between saline and an acidic solution in terms of symptomatic urinary tract infections or time to first catheter change. The data from five trials comparing differing washout policies were sparse and trials were generally of poor quality or poorly reported. The evidence was too scant to conclude whether or not washouts were beneficial. Further rigorous, high quality trials with adequate power to detect any benefit from washout rather than no washout being performed are required in the first instance. After that, trials comparing different washout solutions, washout volumes, frequencies/timings, and routes of administration are needed. Copyright © 2011 Wiley-Liss, Inc.
NASA Astrophysics Data System (ADS)
Abraham, Nabil Mathew
Staphylococcus aureus is the causative agent of a diverse array of acute and chronic infections, and some these infections, including infective endocarditis, joint infections, and medical device-associated bloodstream infections, depend upon its capacity to form tenacious biofilms on surfaces. Inserted medical devices such as intravenous catheters, pacemakers, and artificial heart valves save lives, but unfortunately, they can also serve as a substrate on which S. aureus can form a biofilm, attributing S. aureus as a leading cause of medical device-related infections. The major aim of this work was take compounds to which S. aureus would be exposed during infection and to investigate their effects on its capacity to form a biofilm. More specifically, the project investigated the effects of serum, and thereafter of catheter lock solutions on biofilm formation by S. aureus. Pre-coating polystyrene with serum is frequently used as a method to augment biofilm formation. The effect of pre-coating with serum is due to the deposition of extracellular matrix components onto the polystyrene, which are then recognized by MSCRAMMs. We therefore hypothesized that the major component of blood, serum, would induce biofilm formation. Surprisingly, serum actually inhibited biofilm formation. The inhibitory activity was due to a small molecular weight, heat-stable, non-proteinaceous component/s of serum. Serum-mediated inhibition of biofilm formation may represent a previously uncharacterized aspect of host innate immunity that targets the expression of a key bacterial virulence factor: the ability to establish a resistant biofilm. Metal ion chelators like sodium citrate are frequently chosen to lock intravenous catheters because they are regarded as potent inhibitors of bacterial biofilm formation and viability. We found that, while chelating compounds abolished biofilm formation in most strains of S. aureus, they actually augmented the phenotype in a subset of strains. We investigated the molecular basis of this phenomenon. Deletion and complementation analysis and thereafter antibody based inhibition assays confirmed a functional role for the surface adhesin clumping factor B as the causative determinant associated with the increased biofilm phenotype. Finally, we investigated the regulation of clumping factor B-mediated biofilm formation and the basis for the strain dependence. Regulation was determined to occur via two novel post-translational networks- one affecting ClfB activity, mediated by Ca2+ binding to the EF-Hand domain, and the other affecting protein stability, mediated by the enzymatic activity of the metalloprotease-aureolysin. Polymorphisms within the aureolysin gene sequence, between strains, was identified as the basis for some strains forming robust biofilms within chelated media versus other than do not exhibit this phenotype.
ERIC Educational Resources Information Center
Villano, Matt
2008-01-01
Building access control (BAC)--a catchall phrase to describe the systems that control access to facilities across campus--has traditionally been handled with remarkably low-tech solutions: (1) manual locks; (2) electronic locks; and (3) ID cards with magnetic strips. Recent improvements have included smart cards and keyless solutions that make use…
Exercise to reduce the escalation of cocaine self-administration in adolescent and adult rats.
Zlebnik, Natalie E; Anker, Justin J; Carroll, Marilyn E
2012-12-01
Concurrent access to an exercise wheel decreases cocaine self-administration under short access (5 h/day for 5 days) conditions and suppresses cocaine-primed reinstatement in adult rats. The effect of exercise (wheel running) on the escalation of cocaine intake during long access (LgA, 6 h/day for 26 days) conditions was evaluated. Adolescent and adult female rats acquired wheel running, and behavior was allowed to stabilize for 3 days. They were then implanted with an iv catheter and allowed to self-administer cocaine (0.4 mg/kg, iv) during 6-h daily sessions for 16 days with concurrent access to either an unlocked or a locked running wheel. Subsequently, for ten additional sessions, wheel access conditions during cocaine self-administration sessions were reversed (i.e., locked wheels became unlocked and vice versa). In the adolescents, concurrent access to the unlocked exercise wheel decreased responding for cocaine and attenuated escalation of cocaine intake irrespective of whether the locked or unlocked condition came first. However, cocaine intake increased when the wheel was subsequently locked for the adolescents that had initial access to an unlocked wheel. Concurrent wheel access either before or after the locked wheel access did not reduce cocaine intake in adults. Wheel running reduced cocaine intake during LgA conditions in adolescent but not adult rats, and concurrent access to the running wheel was necessary. These results suggest that exercise prevents cocaine seeking and that this effect is more pronounced in adolescents than adults.
Washout policies in long-term indwelling urinary catheterisation in adults.
Shepherd, Ashley J; Mackay, William G; Hagen, Suzanne
2017-03-06
People requiring long-term bladder draining with an indwelling catheter can experience catheter blockage. Regimens involving different solutions can be used to wash out catheters with the aim of preventing blockage. This is an update of a review published in 2010. To determine if certain washout regimens are better than others in terms of effectiveness, acceptability, complications, quality of life and critically appraise and summarise economic evidence for the management of long-term indwelling urinary catheterisation in adults. We searched the Cochrane Incontinence Group Specialised Trials Register, which contains trials identified from the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, MEDLINE In-Process, MEDLINE Epub Ahead of Print, CINAHL, ClinicalTrials.gov, WHO ICTRP and handsearching of journals and conference proceedings to 23 May 2016. We also examined all reference lists of identified trials and contacted manufacturers and researchers in the field. All randomised and quasi-randomised trials comparing catheter washout policies (e.g. washout versus no washout, different washout solutions, frequency, duration, volume, concentration, method of administration) in adults (aged 16 years and above) in any setting (i.e. hospital, nursing/residential home, community) with an indwelling urethral or suprapubic catheter for more than 28 days. Two review authors independently extracted data. Disagreements were resolved by discussion. Data were assessed and analysed as described in the Cochrane Handbook. If data in trials were not fully reported, clarification was sought from the study authors. For categorical outcomes, the numbers reporting an outcome were related to the numbers at risk in each group to derive a risk ratio (RR). For continuous outcomes, means and standard deviations were used to derive mean differences (MD). We included seven trials involving a total of 349 participants, 217 of whom completed the studies. Three were cross-over and four were parallel-group randomised controlled trials (RCTs). Of these, two trials were added for this update (one parallel-group RCT with 40 participants and one cross-over RCT with 67 participants). Analyses of three cross-over trials yielded suboptimal results because they were based on between-group differences rather than individual participants' differences for sequential interventions. Two parallel-group trials had limited clinical value: one combined results for suprapubic and urethral catheters and the other provided data for only four participants. Only one trial was free of significant methodological limitations, but there were difficulties with recruitment and maintaining participants in this study.The included studies reported data on six of the nine primary and secondary outcome measures. None of the trials addressed: number of catheters used, washout acceptability measures (including patient satisfaction, patient discomfort, pain and ease of use), or health status/measures of psychological health; very limited data were collected for health economic outcomes. Trials assessed only three of the eight intervention comparisons identified. Two trials reported in more than one comparison group.Four trials compared washout (either saline or acidic solution) with no washout. We are uncertain if washout solutions (saline or acidic), compared to no washout solutions, has an important effect on the rate of symptomatic urinary tract infection or length of time each catheter was in situ because the results are imprecise.Four trials compared different types of washout solution; saline versus acidic solutions (2 trials); saline versus acidic solution versus antibiotic solution (1 trial); saline versus antimicrobial solution (1 trial). We are uncertain if type of washout solution has an important effect on the rate of symptomatic urinary tract infection or length of time each catheter was in situ because the results are imprecise.One trial compared different compositions of acidic solution (stronger versus weaker solution). We are uncertain if different compositions of acidic solutions has an important effect on the rate of symptomatic urinary tract infection or length of time each catheter was in situ because only 14 participants (of 25 who were recruited) completed this 12 week, three arm trial.Four studies reported on possible harmful effects of washout use, such as blood in the washout solution, changes in blood pressure and bladder spasms.There were very few small trials that met the review inclusion criteria. The high risk of bias of the included studies resulted in the evidence being graded as low or very low quality. Data from seven trials that compared different washout policies were limited, and generally, of poor methodological quality or were poorly reported. The evidence was not adequate to conclude if washouts were beneficial or harmful. Further rigorous, high quality trials that are adequately powered to detect benefits from washout being performed as opposed to no washout are needed. Trials comparing different washout solutions, washout volumes, and frequencies or timings are also needed.
Mode locking and island suppression by resonant magnetic perturbations in Rutherford regime
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Wenlong; Zhu, Ping, E-mail: pzhu@ustc.edu.cn
We demonstrate in theory that tearing mode locking and magnetic island suppression by resonant magnetic perturbations (RMPs) can correspond to different states of a same dynamic system governed by the torque balance and the nonlinear island evolution in the Rutherford regime. In particular, mode locking corresponds to the exact steady state of this system. A new exact analytic solution has been obtained for such a steady state, which quantifies the dependence of the locked mode island width on RMP amplitude in different plasma regimes. Furthermore, two different branches of mode locking have been revealed with the new analytic solution andmore » the branch with suppressed island width turns out to be unstable in general. On the other hand, the system also admits stable states of island suppression achieved through the RMP modulation of tearing mode rotational frequency. When the RMP amplitude is above a certain threshold, the island suppression is transient until the tearing mode eventually gets locked. When the RMP amplitude is below the mode locking threshold, the island can be suppressed in a steady state on time-average, along with transient oscillations in rotational frequency and island width due to the absence of mode locking.« less
Tunable triple-wavelength mode-locked fiber laser with topological insulator Bi2Se3 solution
NASA Astrophysics Data System (ADS)
Guo, Bo; Yao, Yong
2016-08-01
We experimentally demonstrated a tunable triple-wavelength mode-locked erbium-doped fiber laser with few-layer topological insulator: Bi2Se3/polyvinyl alcohol solution. By properly adjusting the pump power and the polarization state, the single-, dual-, and triple-wavelength mode-locking operation could be stably initiated with a wavelength-tunable range (˜1 nm) and a variable wavelength spacing (1.7 or 2 nm). Meanwhile, it exhibits the maximum output power of 10 mW and pulse energy of 1.12 nJ at the pump power of 175 mW. The simple, low-cost triple-wavelength mode-locked fiber laser might be applied in various potential fields, such as optical communication, biomedical research, and sensing system.
Insulin compatibility with polymer materials used in external pump infusion systems.
Melberg, S G; Havelund, S; Villumsen, J; Brange, J
1988-04-01
In a study designed to mimic actual user conditions for external insulin pump infusion, the insulin quality after passage through the infusion set was assessed by various analytical methods, including high performance liquid chromatography. The two infusion sets tested consisted of, firstly, a polyvinylchloride/rubber syringe and a polyvinylchloride catheter sterilized by gamma irradiation and, secondly, a polyethylene/polypropylene syringe connected to a polyethylene catheter and sterilized by ethylene oxide. The insulin solution delivered through the PVC infusion set showed a reduction of preservative to less than 30% of the initial content and increased formation of chemical transformation products of insulin varying from twice the reference level during the first day to more than three times on the third day. By contrast, the polyethylene/polypropylene infusion system showed only a minor decrease in preservative content and no increase in chemical transformation. These effects were observed irrespective of the brand of insulin and were not affected by increase of the zinc content of the insulin solution. Investigation of the influence of the sterilization methods performed on polyvinylchloride and polyethylene catheters revealed that gamma irradiated polyvinylchloride catheters were markedly harmful to the insulin solution, whereas ethylene oxide sterilization did not influence the chemical stability of insulin.
Catheter tracking in an interventional photoacoustic surgical system
NASA Astrophysics Data System (ADS)
Cheng, Alexis; Itsarachaiyot, Yuttana; Kim, Younsu; Zhang, Haichong K.; Taylor, Russell H.; Boctor, Emad M.
2017-03-01
In laparoscopic medical procedures, accurate tracking of interventional tools such as catheters are necessary. Current practice for tracking catheters often involve using fluoroscopy, which is best avoided to minimize radiation dose to the patient and the surgical team. Photoacoustic imaging is an emerging imaging modality that can be used for this purpose and does not currently have a general tool tracking solution. Photoacoustic-based catheter tracking would increase its attractiveness, by providing both an imaging and tracking solution. We present a catheter tracking method based on the photoacoustic effect. Photoacoustic markers are simultaneously observed by a stereo camera as well as a piezoelectric element attached to the tip of a catheter. The signals received by the piezoelectric element can be used to compute its position relative to the photoacoustic markers using multilateration. This combined information can be processed to localize the position of the piezoelectric element with respect to the stereo camera system. We presented the methods to enable this work and demonstrated precisions of 1-3mm and a relative accuracy of less than 4% in four independent locations, which are comparable to conventional systems. In addition, we also showed in another experiment a reconstruction precision up to 0.4mm and an estimated accuracy up to 0.5mm. Future work will include simulations to better evaluate this method and its challenges and the development of concurrent photoacoustic marker projection and its associated methods.
Parallel Digital Phase-Locked Loops
NASA Technical Reports Server (NTRS)
Sadr, Ramin; Shah, Biren N.; Hinedi, Sami M.
1995-01-01
Wide-band microwave receivers of proposed type include digital phase-locked loops in which band-pass filtering and down-conversion of input signals implemented by banks of multirate digital filters operating in parallel. Called "parallel digital phase-locked loops" to distinguish them from other digital phase-locked loops. Systems conceived as cost-effective solution to problem of filtering signals at high sampling rates needed to accommodate wide input frequency bands. Each of M filters process 1/M of spectrum of signal.
Morrison, James; Kaufman, John
2016-12-01
Vascular access is invaluable in the treatment of hospitalized patients. Central venous catheters provide a durable and long-term solution while saving patients from repeated needle sticks for peripheral IVs and blood draws. The initial catheter placement procedure and long-term catheter usage place patients at risk for infection. The goal of this project was to develop a system to track and evaluate central line-associated blood stream infections related to interventional radiology placement of central venous catheters. A customized web-based clinical database was developed via open-source tools to provide a dashboard for data mining and analysis of the catheter placement and infection information. Preliminary results were gathered over a 4-month period confirming the utility of the system. The tools and methodology employed to develop the vascular access tracking system could be easily tailored to other clinical scenarios to assist in quality control and improvement programs.
Puiggròs, C; Cuerda, C; Virgili, N; Chicharro, M L; Martínez, C; Garde, C; de Luis, D
2012-01-01
In adult home parenteral nutrition (HPN) programme patients up to now no evidence-based recommendations exist on the central venous catheter maintenance nor venous thrombosis prevention. The use of heparin flushes could be linked with long term complications, besides, anticoagulants use is controversial. To be aware of the usual maintenance practice for HPN central venous catheters, catheter occlusion and related venous thrombosis incidence in our country. Retrospective study of active HPN patients older than 18 years registered by the NADYA- SENPE working group until November 2008. 49 patients were registered (16 males and 33 females), with an average age of 52.1 ± 13.9 years, belonging to 6 hospitals. HPN length was 57.4 ± 73.3 months with 5.8 ± 1.8 PN days a week. The most frequent pathologies were actinic enteritis, intestinal motility disorders and mesenteric ischemia (20.4% each), and neoplasm (16.3%). The reason for HPN provision was short bowel syndrome (49.0%), and intestinal obstruction (28.6%). Neoplasm (16.3%), thrombotic diathesis, thromboembolic syndrome and bed rest (6.1% each) were the main venous thrombosis adjuvant factors. Tunnelled catheters were used in 77.6% of patients, with implanted port-catheters in the remainder. Maintenance of the line was done with saline solution flushes (28.6%) and different concentrations of heparin solutions (69.4%). When heparin was used, it was removed before PN infusion in 63.3% of patients. Catheter occlusion and venous thrombotic events rates were 0.061/10³ and 0.115/10³ HPN days respectively. Eleven patients (22.4%) were treated with anticoagulant drugs due to previous episodes of venous thrombosis or pulmonary embolism. [corrected] The incidence of catheter related thrombotic complications incidence is low in this group of patients on HPN. There is a great variety of practices focused on the prevention of both: line occlusion and catheter related venous thrombosis. In conclusion, it would be necessary to standardize practice.
Theory of porous catheters and their applications in intraparenchymal infusions.
Raghavan, Raghu; Odland, Rick M
2017-01-01
Multiport catheters and catheters with a porous surface have been proposed for intraparenchymal infusions of therapeutics in fluid suspensions. Target diseases include brain cancer and serious neurodegenerative diseases, as well as peripheral tumors, for example in the prostate and the liver. We set up the theory for infusions from such devices, in particular the fluid flow equations which demand a coupling between the flow within the catheter and that in tissue. (Such a coupling is not necessary in the theory of infusion from single port catheters.) The new feature of such catheters, treated by our model, is revealed by infusions into inhomogeneous media. Multiport designs have the potential to overcome the limitation of single port catheters, for which the path of the fluid leaving the port is dominated by the inhomogeneities. We solve these equations for some simple cases to illustrate the key design features of porous catheters that show such advantages. The mathematics required for numerical solution with more realistic assumptions is also developed. We confirm the robustness of such catheters, when the ports are sufficiently resistive, against leakage paths that would compromise the infusions from catheters with one or a few large ports. The methods of this paper can be incorporated into a larger planning system for intraparenchymal infusions involving such devices.
Infective endocarditis in a hemodialysis patient: a dreaded complication.
Schubert, Claudia; Moosa, Mohammed R
2007-10-01
Infection is the most common cause of death in hemodialysis patients, after cardiovascular disease. Dialysis access infections, with secondary septicemia, contribute significantly to patient mortality. The most common source is temporary catheterization. Bacteremia occurs commonly in patients receiving hemodialysis, with infective endocarditis being a relatively uncommon, but potentially lethal complication. Valvular calcification is the most significant risk factor. The diagnosis of infective endocarditis is made clinically and confirmed with the echocardiographic modified Duke's criteria. The most common pathogen is Staphylococcus aureus and the mitral valve is the most common site. Staphylococcus aureus infective endocarditis is commonly associated with embolic phenomenon. A high index of suspicion is critical in the early recognition and management of infective endocarditis. However, prevention of bacteremia is undoubtedly the best strategy with the early placement of arteriovenous fistulae. In the case of temporary catheterization, the use of topical mupirocin or polysporin and gentamicin and/or citrate locking is beneficial. Although catheter salvage has not been studied in randomized trials, catheter removal remains standard therapy during bacteremia.
Rational choice of peritoneal dialysis catheter.
Dell'Aquila, Roberto; Chiaramonte, Stefano; Rodighiero, Maria Pia; Spanó, Emilia; Di Loreto, Pierluigi; Kohn, Catalina Ocampo; Cruz, Dinna; Polanco, Natalia; Kuang, Dingwei; Corradi, Valentina; De Cal, Massimo; Ronco, Claudio
2007-06-01
The peritoneal catheter should be a permanent and safe access to the peritoneal cavity. Catheter-related problems are often the cause of permanent transfer to hemodialysis (HD) in up to 20% of peritoneal dialysis (PD) patients; in some cases, these problems require a temporary period on HD. Advances in connectology have reduced the incidence of peritonitis, and so catheter-related complications during PD have become a major concern. In the last few years, novel techniques have emerged in the field of PD: new dialysis solutions, better connectology, and cyclers for automated PD. However, extracorporeal dialysis has continued to improve in terms of methods and patient survival, but PD has failed to do so. The main reason is that peritoneal access has remained problematical. The peritoneal catheter is the major obstacle to wide-spread use of PD. Overcoming catheter-related problems means giving a real chance to development of the peritoneal technique. Catheters should be as efficient, safe, and acceptable as possible. Since its introduction in the mid-1960s, the Tenckhoff catheter has not become obsolete: dozens of new models have been proposed, but none has significantly reduced the pre-dominance of the first catheter. No convincing prospective data demonstrate the superiority of any peritoneal catheter, and so it seems that factors other than choice of catheter are what affect survival and complication rates. Efforts to improve peritoneal catheter survival and complication rates should probably focus on factors other than the choice of catheter. The present article provides an overview of the characteristics of the best-known peritoneal catheters.
Dettenkofer, M; Jonas, D; Wiechmann, C; Rossner, R; Frank, U; Zentner, J; Daschner, F D
2002-10-01
We investigated the efficacy of two commercially available, alcohol-based antiseptic solutions in decontaminating the insertion site of central lines. One solution contained the bispyridine octenidine dihydrochloride. Inpatients receiving either a central venous catheter (CVC) or a peripherally inserted central catheter (PICC) were alternately assigned to different skin disinfection regimens at the insertion site: (A) 0.1% octendine dihydrochloride with 30% 1-propanol and 45% 2-propanol, (B) 74% ethanol with 10% 2-propanol. Quantitative skin cultures were obtained from the insertion site at predetermined intervals. A total of 60 patients received 12 CVCs and 47 PICCs (no significant difference with respect to gender, age and catheter type). In total, 90 cultures were assessed in each group. The median colony-forming unit (cfu) counts per 24 cm(2) (group A vs B) were 2,270 vs 2,950 before, 20 vs 40 following and 860 vs 1,210 24 h after catheter insertion, respectively. A statistically significant difference in the efficacy of skin decontamination was seen between groups in culture set (3) and in the difference between culture sets (2) and (3) (Wilcoxon rank sum test). Octenidine/propanol appears to be more effective than alcohol (ethanol/propanol) alone in reducing microflora of the skin at the PICC/CVC insertion site over a 24-h period.
2009-02-12
describes the mode- locking and dynamics of solitons . A characteristic of short pulse lasers is the carrier-envelope phase (CEP) slip which is the change in...and evolution of pulses in mode- locked lasers that are operating in the soliton regime. To describe our research in more detail, we fix typical...solutions with mode- locking evolution. Otherwise the solitons are found to be unstable; either dispersing to radiation or evolving into nonlocalized
Fully synchronous solutions and the synchronization phase transition for the finite-N Kuramoto model
NASA Astrophysics Data System (ADS)
Bronski, Jared C.; DeVille, Lee; Jip Park, Moon
2012-09-01
We present a detailed analysis of the stability of phase-locked solutions to the Kuramoto system of oscillators. We derive an analytical expression counting the dimension of the unstable manifold associated to a given stationary solution. From this we are able to derive a number of consequences, including analytic expressions for the first and last frequency vectors to phase-lock, upper and lower bounds on the probability that a randomly chosen frequency vector will phase-lock, and very sharp results on the large N limit of this model. One of the surprises in this calculation is that for frequencies that are Gaussian distributed, the correct scaling for full synchrony is not the one commonly studied in the literature; rather, there is a logarithmic correction to the scaling which is related to the extremal value statistics of the random frequency vector.
Wu, Hsiang-Ling; Tai, Ying-Hsuan; Wei, Ling-Fang; Cheng, Hung-Wei; Ho, Chiu-Ming
2017-10-01
There is no current consensus on which lumen an airway exchange catheter (AEC) should be passed through in double-lumen endotracheal tube (DLT) to exchange for a single-lumen endotracheal tube (SLT) after thoracic surgery. We report an unusual case to provide possible solution on this issue. A 71-year-old man with lung adenocarcinoma had an event of a broken exchange catheter used during a DLT replacement with a SLT, after a video-assisted thoracic surgery. The exchange catheter was impinged at the distal tracheal lumen and snapped during manipulation. All three segments of the catheter were retrieved without further airway compromises. Placement of airway tube exchanger into the tracheal lumen of double-lumen tube is a potential contributing factor of the unusual complication. We suggest an exchange catheter be inserted into the bronchial lumen in optimal depth with the adjunct of video laryngoscope, as the safe method for double-lumen tube exchange.
Complete spatial and temporal locking in phase-mismatched second-harmonic generation.
Fazio, Eugenio; Pettazzi, Federico; Centini, Marco; Chauvet, Mathieu; Belardini, Alessandro; Alonzo, Massimo; Sibilia, Concita; Bertolotti, Mario; Scalora, Micheal
2009-03-02
We experimentally demonstrate simultaneous phase and group velocity locking of fundamental and generated second harmonic pulses in Lithium Niobate, under conditions of material phase mismatch. In phase-mismatched, pulsed second harmonic generation in addition to a reflected signal two forward-propagating pulses are also generated at the interface between a linear and a second order nonlinear material: the first pulse results from the solution of the homogeneous wave equation, and propagates at the group velocity expected from material dispersion; the second pulse is the solution of the inhomogeneous wave equation, is phase-locked and trapped by the pump pulse, and follows the pump trajectory. At normal incidence, the normal and phase locked pulses simply trail each other. At oblique incidence, the consequences can be quite dramatic. The homogeneous pulse refracts as predicted by material dispersion and Snell's law, yielding at least two spatially separate second harmonic spots at the medium's exit. We thus report the first experimental results showing that, at oblique incidence, fundamental and phase-locked second harmonic pulses travel with the same group velocity and follow the same trajectory. This is direct evidence that, at least up to first order, the effective dispersion of the phase-locked pulse is similar to the dispersion of the pump pulse.
Pai, Vinita B; Plogsted, Steven
2014-10-01
Critically ill pediatric patients, especially in the intensive care unit, receive multiple medications and have a higher risk of central venous catheter (CVC) occlusion. If an occlusion occurs immediately after the administration of multiple medications or incompatible medications, either an acidic solution such as 0.1 N hydrochloric acid (HCl) or a basic solution of 1 mEq/mL sodium bicarbonate or 0.1 N sodium hydroxide can be used. However, compounding and storing of 0.1 N HCl has become more complex due to USP <797> guidelines for sterile compounding, and an alternative is needed. We report a series of cases in which L-cysteine was used instead of HCl to clear CVCs occluded due to administration of multiple medications. L-cysteine is a commercially available, sterile solution with a pH of 1–2.5. CVC occlusion was resolved in 10 of the 16 episodes in 13 patients. Two of the 16 occlusions were phenytoin related and would not have responded. An L-cysteine dose of 50 mg was used during 10 of the 16 episodes, 100 mg during 5 episodes, and 25 mg during 1 episode. A correlation between catheter clearance and dose was not observed. Occlusion resolution due to L-cysteine was not correlated to the prior use of tissue plasminogen activator. Metabolic acidosis, adverse effects, or damage to the catheters due to L-cysteine were not observed. On the basis of this limited experience, we propose L-cysteine as an effective alternative to 0.1 N HCl for clearing CVC occlusions caused by drugs with an acidic pKa.
Wang, Peng; Zheng, Yefeng; John, Matthias; Comaniciu, Dorin
2012-01-01
Dynamic overlay of 3D models onto 2D X-ray images has important applications in image guided interventions. In this paper, we present a novel catheter tracking for motion compensation in the Transcatheter Aortic Valve Implantation (TAVI). To address such challenges as catheter shape and appearance changes, occlusions, and distractions from cluttered backgrounds, we present an adaptive linear discriminant learning method to build a measurement model online to distinguish catheters from background. An analytic solution is developed to effectively and efficiently update the discriminant model and to minimize the classification errors between the tracking object and backgrounds. The online learned discriminant model is further combined with an offline learned detector and robust template matching in a Bayesian tracking framework. Quantitative evaluations demonstrate the advantages of this method over current state-of-the-art tracking methods in tracking catheters for clinical applications.
Low vacuum and discard tubes reduce hemolysis in samples drawn from intravenous catheters.
Heiligers-Duckers, Connie; Peters, Nathalie A L R; van Dijck, Jose J P; Hoeijmakers, Jan M J; Janssen, Marcel J W
2013-08-01
In-vitro hemolysis is a great challenge to emergency departments where blood is drawn from intravenous catheters (IVCs). Although high quality samples can be obtained by straight needle venipuncture, IVCs are preferred for various reasons. The aim of this study was to identify blood collection practices that reduce hemolysis while using IVC. The study was conducted at an emergency department where blood is drawn in ≥ 90% of patients from IVC. Hemolysis, measured spectrophotometrically, was compared between syringe and vacuum tubes. The following practices were tested in combination with vacuum collection; a Luer-slip adapter, a Luer-lock adapter, discard tubes and low vacuum tubes. Each intervention lasted 1 week and retrieved 154 to 297 samples. As reference, hemolysis was also measured in vacuum tubes retrieved from departments where only straight needle venipuncture is performed. Vacuum collection led to more hemolytic samples compared with syringe tubes (24% versus 16% respectively, p=0.008). No difference in hemolysis was observed between the Luer-slip and the Luer-lock adapter. The use of discard (17% hemolytic, p=0.045) and low vacuum tubes (12% hemolytic, p<0.001) substantially decreased hemolysis. None of the interventions reduced the hemolysis rate to the level observed when drawing blood by straight needle venipuncture (3%, p<0.02). In summary, both discard and low vacuum tubes reduce hemolysis while drawing blood from IVC. Of these practices the use of a low vacuum tube is preferred considering the less volume of blood and the amount of tubes drawn. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Erdogan, Hakan; Altun, Adnan; Kuruoglu, Enis; Kaya, Ahmet Hilmi; Dagcinar, Adnan
2017-09-26
Ventriculoatrial (VA) shunting is a well-described cerebrospinal fluid diversion method for the treatment of hydrocephalus. However, it may be very challenging in infants and little children because of atrial catheter placement difficulties. This study aimed to create an algorithm to solve problems faced during open surgical procedures based on the present authors' experience. We conducted a retrospective analysis on 18 infants and children who underwent VA shunt insertion at the Department of Neurosurgery, Ondokuz Mayıs University School of Medicine Hospital between 2005 and 2012. Complications, clinical outcomes, revisions, and solutions for overcoming distal catheter placement difficulties were evaluated. Twenty-six VA shunt operations were performed in 18 patients. Six patients required eight VA shunt revisions. VA shunting was primarily performed from the internal jugular, facial, cephalic, and subclavian veins to the right atrium. In revision procedures, the internal jugular, cephalic, and subclavian veins were used. VA shunting in infants and little children requires careful surgical techniques. Neurosurgeons should necessarily have an appropriate strategy for VA shunting considering the complications and revisions. Our results suggest open surgical solutions to overcome distal catheter placement difficulties in this age group.
Eom, Jung Seop; Kim, Tae Hwa; Lee, Geewon; Ahn, Hyo Yeong; Mok, Jeong Ha; Lee, Min Ki
2017-05-01
We present three cases of successful chemical pleurodesis with a liquid solution of mistletoe extract using a spray catheter during medical thoracoscopy. The medical thoracoscopy was performed in all presented cases to remove pleural effusion and conduct chemical pleurodesis to manage symptomatic malignant pleural effusion. A spray catheter was used to instil the mistletoe extract evenly into the pleural cavity, and there were no pleurodesis-related complications. Respiratory symptoms caused by pleural effusion improved after pleurodesis, and successful pleurodesis was maintained for more than 3 months after medical thoracoscopy in all three patients.
Singh, Tikam; Lal, S S
2011-06-01
The primary aim of in vitro culture of whipworms (Trichuris ovis) is to provide artificial conditions under which the life cycle of the parasites completed outside the host under controlled conditions. The physiological solutions used for the present study were sodium chloride (0.64%), Ringer's solution, Tyrode's solution, and Lock-Lewis solution. Parasites were collected from freshly slaughtered intestine of the host. The recovered parasites were washed with running tap water after that with normal saline. After washing parasites were put in four petridishes containing different physiological solutions. Observations were recorded after interval of every 8 h. The hundred percent survival of Trichuris ovis was observed at 32, 40, and 48 h in NaCl (0.64%), Ringer's, Tyrode's, and Lock-Lewis solution, respectively in case of both male and female parasites. In sodium chloride solution (0.64%) cent percent mortality was observed after 64 h of incubation in males and in case of females it was observed 72 h. In Ringer's solution cent percent mortality was observed after 72 in males and in females it was observed 80 h. In Tyrode's solution cent percent mortality was observed after 88 h in males and 96 h in females. In Lock-Lewis solution cent percent mortality was observed after 96 h in case of both the male and female parasites. Present study could be used to understand the effects of various drugs on the above parasites and also other intra-intestinal parasites.
Le Guilchet, T; Audenet, F; Hurel, S; Beaugerie, A; Fontaine, E; Terrier, N; Timsit, M O; Mejean, A
2016-03-01
Ureteral stents and ureteral catheters externalized through the urethra are not ideal solutions to manage complicated upper urinary tract fistulae. We sought an effective method of drainage, minimally invasive, reproducible allowing a rapid patient's discharge. Between November 2013 and February 2015, an ureteral stent was exteriorized in trans-vesico-parietal by an endoscopic and percutaneous access in patients with complicated upper urinary tract fistulae. Monitoring of tolerance, complications and urinary fistula healing was performed. Nine consecutive patients had an ureteral stent exteriorized in trans-vesico-parietal to manage complicated upper urinary tract fistulae. There was no failure in introducing the catheter, or postoperative complication. Catheters were left in place on average 36.1days (24-55). The patients were able to return home with the catheter in place in 77.8% of cases. The tolerance of the catheter was good. All fistulae were able to be treated conservatively at the end of the drainage period. Trans-vesico-parietal ureteral catheters enable efficient and reproducible conservative treatment of upper tract urinary fistulae regardless of their cause. 5. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Heudorf, Ursel; Grünewald, Miriam; Otto, Ulla
2016-01-01
The Commission for Hospital Hygiene and Infection Prevention (KRINKO) updated the recommendations for the prevention of catheter-associated urinary tract infections in 2015. This article will describe the implementation of these recommendations in Frankfurt's hospitals in autumn, 2015. In two non-ICU wards of each of Frankfurt's 17 hospitals, inspections were performed using a checklist based on the new KRINKO recommendations. In one large hospital, a total of 5 wards were inspected. The inspections covered the structure and process quality (operating instructions, training, indication, the placement and maintenance of catheters) and the demonstration of the preparation for insertion of a catheter using an empty bed and an imaginary patient, or insertion in a model. Operating instructions were available in all hospital wards; approximately half of the wards regularly performed training sessions. The indications were largely in line with the recommendations of the KRINKO. Alternatives to urinary tract catheters were available and were used more often than the urinary tract catheters themselves (15.9% vs. 13.5%). In accordance with the recommendations, catheters were placed without antibiotic prophylaxis or the instillation of antiseptic or antimicrobial substances or catheter flushing solutions. The demonstration of catheter placement was conscientiously performed. Need for improvement was seen in the daily documentation and the regular verification of continuing indication for a urinary catheter, as well as the omission of regular catheter change. Overall, the recommendations of the KRINKO on the prevention of catheter-associated urinary tract infections were adequately implemented. However, it cannot be ruled out that in situations with time pressure and staff shortage, the handling of urinary tract catheters may be of lower quality than that observed during the inspections, when catheter insertion was done by two nurses. Against this background, a sufficient number of qualified staff and regular ward rounds by the hygiene staff appear recommendable.
Central venous access in children: indications, devices, and risks.
Ares, Guillermo; Hunter, Catherine J
2017-06-01
Central venous catheters (CVCs) have a prominent role in the diagnostic and therapy of neonates and children. Herein, we describe the multiple indications for CVC use and the different devices available for central venous access. Given the prevalent use of CVCs, healthcare systems are focused on reducing complications from their use, particularly central line-associated bloodstream infections (CLABSIs). The most up-to-date information available sheds light on best practices and future areas of investigation. Large systematic reviews of randomized trials suggest that ultrasound guidance for placement of CVCs in children is safer than using blind technique, at least for internal jugular vein access. Appropriate catheter tip placement is associated with decreased complications. Furthermore, the prophylactic use of ethanol lock between cycles of parenteral nutrition administration has reduced the rates of CLABSI. A recent randomized trial in pediatric CVCs showed a benefit with antibiotic-coated CVCs. Based on the available evidence, multiple techniques for CVC placement are still valid, including the landmark technique based on practitioner experience, but ultrasound guidance has been shown to decrease complications from line placement. Adherence to CVC care protocols is essential in reducing infectious complications.
Minocycline Inhibits Candida albicans Budded-to-Hyphal-Form Transition and Biofilm Formation.
Kurakado, Sanae; Takatori, Kazuhiko; Sugita, Takashi
2017-09-25
Candida albicans frequently causes bloodstream infections; its budded-to-hyphalform transition (BHT) and biofilm formation are major contributors to virulence. During an analysis of antibacterial compounds that inhibit C. albicans BHT, we found that the tetracycline derivative minocycline inhibited BHT and subsequent biofilm formation. Minocycline decreased expression of hypha-specific genes HWP1 and ECE1, and adhesion factor gene ALS3 of C. albicans. In addition, minocycline decreased cell surface hydrophobicity and the extracellular β-glucan level in biofilms. Minocycline has been widely used for catheter antibiotic lock therapy to prevent bacterial infection; this compound may also be prophylactically effective against Candida infection.
You, Tao; Jiang, Jianliang; Chen, Jianchang; Xu, Weiting; Xiang, Li; Jiao, Yang
2017-01-01
Heparin has typically been used as a flushing or infusion solution for vascular lines in daily practice. However, several clinical trials have yielded controversial results about the benefits of heparin in maintaining peripheral venous catheters. The present meta-analysis was conducted to evaluate the efficacy of heparin on the patency profiles and complications in peripheral intravenous catheters. PubMed, Embase and Cochrane Central Register of Controlled Trials were searched up to February 2016 for randomized controlled trials comparing heparin with placebo in maintaining peripheral intravenous catheters. Additional studies were retrieved from the reference lists of identified articles. In total 32 eligible studies were included, from which the pooled standard mean difference (SMD), relative risk (RR) and corresponding 95% confidence interval (CI) were calculated. The use of heparin as a continuous infusion significantly prolonged the duration of patency (SMD, 0.90; 95% CI, 0.48–1.32; P<0.001), reduced rates of infusion failure (RR, 0.83; 95% CI, 0.76–0.92; P<0.001) and occlusion (RR, 0.82; 95% CI, 0.69–0.98; P<0.05) in a peripheral intravenous catheter. However, there were no significant changes in the duration of patency and infusion failure when heparin was used intermittently as a flushing solution, although a significantly decreased risk of occlusion was observed in this setting (RR, 0.80; 95% CI, 0.66–0.98; P<0.05). Furthermore, the risk of phlebitis was significantly decreased by both continuous infusion (RR, 0.66; 95% CI, 0.58–0.75; P<0.01) and intermittent flushing (RR, 0.70; 95% CI, 0.56–0.86; P<0.01) of heparin in peripheral venous catheters. In conclusion, the use of heparin as continuous infusion in peripheral intravenous catheters improved the duration of patency, reduced infusion failure and phlebitis, whereas heparin as intermittent flushing showed more benefits in ameliorating phlebitis rather than in patency profiles. PMID:28810636
Mitchell, Brett G; Fasugba, Oyebola; Gardner, Anne; Koerner, Jane; Collignon, Peter; Cheng, Allen C; Graves, Nicholas; Morey, Peter; Gregory, Victoria
2017-11-28
Despite advances in infection prevention and control, catheter-associated urinary tract infections (CAUTIs) are common and remain problematic. A number of measures can be taken to reduce the risk of CAUTI in hospitals. Appropriate urinary catheter insertion procedures are one such method. Reducing bacterial colonisation around the meatal or urethral area has the potential to reduce CAUTI risk. However, evidence about the best antiseptic solutions for meatal cleaning is mixed, resulting in conflicting recommendations in guidelines internationally. This paper presents the protocol for a study to evaluate the effectiveness (objective 1) and cost-effectiveness (objective 2) of using chlorhexidine in meatal cleaning prior to catheter insertion, in reducing catheter-associated asymptomatic bacteriuria and CAUTI. A stepped wedge randomised controlled trial will be undertaken in three large Australian hospitals over a 32-week period. The intervention in this study is the use of chlorhexidine (0.1%) solution for meatal cleaning prior to catheter insertion. During the first 8 weeks of the study, no hospital will receive the intervention. After 8 weeks, one hospital will cross over to the intervention with the other two participating hospitals crossing over to the intervention at 8-week intervals respectively based on randomisation. All sites complete the trial at the same time in 2018. The primary outcomes for objective 1 (effectiveness) are the number of cases of CAUTI and catheter-associated asymptomatic bacteriuria per 100 catheter days will be analysed separately using Poisson regression. The primary outcome for objective 2 (cost-effectiveness) is the changes in costs relative to health benefits (incremental cost-effectiveness ratio) from adoption of the intervention. Results will be disseminated via peer-reviewed journals and presentations at relevant conferences.A dissemination plan it being developed. Results will be published in the peer review literature, presented at relevant conferences and communicated via professional networks. Ethics approval has been obtained. 12617000373370, approved 13/03/2017. Protocol version 1.1. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Jung, Bo-Hyun; Hwang, Shin; Ha, Tae-Yong; Song, Gi-Won; Jung, Dong-Hwan; Kim, Ki-Hun; Ahn, Chul-Soo; Moon, Deok-Bog; Park, Gil-Chun; Kang, Sung-Hwa; Yoon, Young-In; Lee, Sung-Gyu
2014-05-01
Conventional graft perfusion method using one small-caliber catheter takes a relatively long time for right liver graft perfusion, thus some modification is needed. In this study, we intended to assess the effectiveness of right liver graft perfusion methods through comparison of different infusion catheters. The study consisted of two parts including one bench experiment to obtain data of hydraulic infusion and one clinical trial of 40 cases on graft perfusion with one- versus two-catheter infusion methods. These two graft infusion methods were compared in terms of the perfusion time and washing-out efficiency. At bench experiment, the infusion flow rate and infusion pressure were 3.3 ml/sec and 1.9 cmH20 in one blood transfusion catheter group, and 11.7 ml/sec and 3.1 cmH20 in single transurethral resection of prostate irrigation catheter group, and 6.6 ml/sec and 2.0 cmH20 in two blood transfusion catheters group, respectively. In clinical trial with 40 right liver grafts, two-catheter group had a shorter graft portal perfusion time for the first 2 L of histidine-tryptophan-ketoglutarate (HTK) solution than the conventional one-catheter group (375±25 seconds vs. 662±34 seconds; p=0.001) and a lower rate of incomplete blood washing-out after the initial 2 L portal perfusion (40% vs. 85%; p=0.03). The two-catheter infusion method appears to be more effective than the conventional one-catheter infusion method for right liver graft perfusion at the back table. Large size of right liver grafts seems to be its good indication.
Siminiak, Tomasz; Dankowski, Rafał; Baszko, Artur; Lee, Christopher; Firek, Ludwik; Kałmucki, Piotr; Szyszka, Andrzej; Groothuis, Adam
2013-01-01
Functional mitral regurgitation (FMR) is known to contribute to a poor prognosis in patients with heart failure (HF). Current guidelines do not recommend cardiac surgery in patients with FMR and impaired ejection fraction due to the high procedural risk. Percutaneous techniques aimed at mitral valve repair may constitute an alternative to currently used routine medical treatment. To provide a description of a novel percutaneous suture-based technique of direct mitral annuloplasty using the Mitralign Bident system, as well as report our first case successfully treated with this method. A deflectable guiding catheter is advanced via the femoral route across the aortic valve to the posterior wall of the ventricle. A nested deflectable catheter is advanced through the guide toward the mitral annulus that allows the advancement of an insulated radiofrequency wire to cross the annulus. The wire is directed across the annulus in a target area that is 2-5 mm from the base of the leaflet into the annulus, as assessed by real-time 3D transoesophageal echocardiography. After placement of the first wire, another wire is positioned using a duel lumen bident delivery catheter, which provides a predetermined separation between wires (i.e. 14, 17 or 21 mm). Each wire provides a guide rail for implantation of sutured pledget implants within the annulus. Two pairs of pledgets are implanted, one pair in each of the P1 and P3 scallop regions of the posterior mitral annulus. A dedicated plication lock device is used to provide a means for plication of the annulus within each pair of the pledgets, and to retain the plication by delivering a suture locking implant. The plications result in improved leaflet coaptation and a reduction of the regurgitant orifice area. A 60-year-old female with diagnosed dilated cardiomyopathy, concomitant FMR class III and congestive HF was successfully treated with the Mitralign Bident system. Two pairs of pledgets were implanted resulting in an improvement of transoesophageal echocardiographic parameters, including proximal isovelocity surface area radius (0.7 cm to 0.4 cm), effective regurgitant orfice area (0.3 cm² to 0.1 cm²) and mitral regurgitant volume (49 mL to 10 mL). Percutaneous mitral annuloplasty with the Mitralign Bident system is feasible. Future clinical trials are needed to assess its safety and efficacy.
The Use of Hypertonic Solutions to Resuscitate Animals from Hypovolemic Shock.
1986-03-18
halothane/nitrous oxide and surgically prepared with chronic cannulations of the thoracic aorta and superior vena cava using silastic catheters placed...and on skeletal muscle inferior vena cava . Heart rate was recorded resting transmembrane potentials. These ef- and blood press.ure was monitored with...nitrous oxide and surgically prepared with chronic cannulations of the thoracic aorta and superior vena cava using silastic catheters placed through a
Curtin, John; Cormican, Martin; Fleming, Gerard; Keelehan, John; Colleran, Emer
2003-01-01
Central venous catheter (CVC)-related infection (CVC-RI) is a common complication of CVC use. The most common etiological agents of CVC-RI are gram-positive organisms, in particular, staphylococci. An in vitro model for the formation of biofilms by Staphylococcus epidermidis ATCC 35984 on polyurethane coupons in a modified Robbins device was established. Biofilm formation was confirmed by electron microscopy and was quantified by determination of viable counts. Mueller-Hinton broth was replaced with sterile physiological saline (control) or a solution of vancomycin (10 mg/ml), gentamicin (10 mg/ml), linezolid (2 mg/ml), or eperezolid (4 mg/ml). Viable counts were performed with the coupons after exposure to antimicrobials for periods of 24, 72, 168, and 240 h. The mean viable count per coupon following establishment of the biofilm was 4.6 × 108 CFU/coupon, and that after 14 days of exposure to physiological saline was 2.5 × 107 CFU/coupon. On exposure to vancomycin (10 mg/ml), the mean counts were 2.5 × 107 CFU/coupon at 24 h, 4.3 × 106 CFU/coupon at 72 h, 1.4 × 105 CFU/coupon at 168 h, and undetectable at 240 h. With gentamicin (10 mg/ml) the mean counts were 2.7 × 107 CFU/coupon at 24 h, 3.7 × 106 CFU/coupon at 72 h, 8.4 × 106 CFU/coupon at 168 h, and 6.5 × 106 CFU/coupon at 240 h. With linezolid at 2 mg/ml the mean counts were 7.1 × 105 CFU/coupon at 24 h and not detectable at 72, 168, and 240 h. With eperezolid (4 mg/ml) no viable cells were recovered after 168 h. These data suggest that linezolid (2 mg/ml) and eperezolid (4 mg/ml) achieve eradication of S. epidermidis biofilms more rapidly than vancomycin (10 mg/ml) and gentamicin (10 mg/ml). PMID:14506022
Kim, Pascal; Meyer, Urs; Schüpfer, Guido; Rukwied, Roman; Konrad, Christoph; Gerber, Helmut
2011-01-01
Epidural analgesia is an established method for pain management. The failure rate is 8% to 12% due to technical difficulties (catheter dislocation and/or disconnection; partial or total catheter occlusion) and management. The mechanical properties of the catheters, like tensile strength and flow rate, may also be affected by the analgesic solution and/or the tissue environment. We investigated the tensile strength and perfusion pressure of new (n=20), perioperatively (n=30), and postoperatively (n=73) used epidural catheters (20-gauge, polyamide, closed tip, 3 side holes; Perifix [B. Braun]). To prevent dislocation, epidural catheters were taped (n=5) or fixed by suture (n=68) to the skin. After removal, mechanical properties were assessed by a tensile-testing machine (INSTRON 4500), and perfusion pressure was measured at flow rates of 10, 20, and 40 mL/h. All catheters demonstrated a 2-step force transmission. Initially, a minimal increase of length could be observed at 15 N followed by an elongation of several cm at additional forces (7 N). Breakage occurred in the control group at 23.5±1.5 N compared with 22.4±1.6 N in perioperative and 22.4±1.7 N in postoperative catheters (P<0.05). Duration of catheter use had no effect on tensile strength, whereas perfusion pressure at clinically used flow rates (10 mL/h) increased significantly from 19±1.3 to 44±72 mm Hg during long-term (≥7 days) epidural analgesia (P<0.05, analysis of variance). Fixation by suture had no influence on tensile strength or perfusion pressure. Epidural catheter use significantly increases the perfusion pressure and decreases the tensile strength. Copyright © 2011 by American Society of Regional Anesthesia and Pain Medicine
Clinical Evaluation of a Safety-device to Prevent Urinary Catheter Inflation Related Injuries.
Davis, Niall F; Cunnane, Eoghan M; Mooney, Rory O'C; Forde, James C; Walsh, Michael T
2018-05-01
To evaluate the feasibility of a novel "safety-valve" device for preventing catheter related urethral trauma during urethral catheterization (UC). To assess the opinions of clinicians on the performance of the safety-valve device. A validated prototype "safety-valve" device for preventing catheter balloon inflation related urethral injuries was prospectively piloted in male patients requiring UC in a tertiary referral teaching hospital (n = 100). The device allows fluid in the catheter system to decant through an activated safety threshold pressure valve if the catheter anchoring balloon is misplaced. Users evaluated the "safety-valve" with an anonymous questionnaire. The primary outcome measurement was prevention of anchoring balloon inflation in the urethra. Secondary outcome measurement was successful inflation of urinary catheter anchoring balloon in the bladder. Patient age was 76 ± 12 years and American Society of Anaesthesiologists grade was 3 ± 1.4. The "safety-valve" was utilized by 34 clinicians and activated in 7% (n = 7/100) patients during attempted UC, indicating that the catheter anchoring balloon was incorrectly positioned in the patient's urethra. In these 7 cases, the catheter was successfully manipulated into the urinary bladder and inflated. 31 of 34 (91%) clinicians completed the questionnaire. Ten percent (n = 3/31) of respondents had previously inflated a urinary catheter anchoring balloon in the urethra and 100% (n = 31) felt that a safety mechanism for preventing balloon inflation in the urethra should be compulsory for all UCs. The safety-valve device piloted in this clinical study offers an effective solution for preventing catheter balloon inflation related urethral injuries. Copyright © 2018 Elsevier Inc. All rights reserved.
Frequency locking in auditory hair cells: Distinguishing between additive and parametric forcing
NASA Astrophysics Data System (ADS)
Edri, Yuval; Bozovic, Dolores; Yochelis, Arik
2016-10-01
The auditory system displays remarkable sensitivity and frequency discrimination, attributes shown to rely on an amplification process that involves a mechanical as well as a biochemical response. Models that display proximity to an oscillatory onset (also known as Hopf bifurcation) exhibit a resonant response to distinct frequencies of incoming sound, and can explain many features of the amplification phenomenology. To understand the dynamics of this resonance, frequency locking is examined in a system near the Hopf bifurcation and subject to two types of driving forces: additive and parametric. Derivation of a universal amplitude equation that contains both forcing terms enables a study of their relative impact on the hair cell response. In the parametric case, although the resonant solutions are 1 : 1 frequency locked, they show the coexistence of solutions obeying a phase shift of π, a feature typical of the 2 : 1 resonance. Different characteristics are predicted for the transition from unlocked to locked solutions, leading to smooth or abrupt dynamics in response to different types of forcing. The theoretical framework provides a more realistic model of the auditory system, which incorporates a direct modulation of the internal control parameter by an applied drive. The results presented here can be generalized to many other media, including Faraday waves, chemical reactions, and elastically driven cardiomyocytes, which are known to exhibit resonant behavior.
Statistical-mechanics theory of active mode locking with noise.
Gordon, Ariel; Fischer, Baruch
2004-05-01
Actively mode-locked lasers with noise are studied employing statistical mechanics. A mapping of the system to the spherical model (related to the Ising model) of ferromagnets in one dimension that has an exact solution is established. It gives basic features, such as analytical expressions for the correlation function between modes, and the widths and shapes of the pulses [different from the Kuizenga-Siegman expression; IEEE J. Quantum Electron. QE-6, 803 (1970)] and reveals the susceptibility to noise of mode ordering compared with passive mode locking.
Impact of the Tactical Picture Quality on the Fire Control Radar Search-Lock-On Time
2006-09-01
theory terminology). It is required to grade the benefits from the different possible actions so that an optimal solution can be chosen. For instance, in...the fire control radar search-lock-on time (U) 4. AUTEURS (Nom de famille, prénom et initiales. Indiquer les grades militaires, ex.: Bleau, Maj
Fry, James; Naqvi, Ali; Bahia, Amit; Seto, Arnold
2017-03-01
A 52-year-old Asian male with no traditional risk factors for coronary artery disease presented with acute coronary syndrome. Coronary angiography showed complete thrombotic occlusion of the left circumflex with a large thrombus burden in the setting of diffuse aneurysmal enlargement of the coronary arteries consistent with antecedent Kawasaki disease. Manual thrombectomy with adjunctive intracoronary tirofiban was performed utilizing the GuideLiner catheter ® (Vascular Solutions, Inc., MN, USA). Stent implantation was deferred. Follow-up imaging 48 h later showed preserved coronary flow and decreased thrombus burden. The GuideLiner catheter, a monorail guiding device, served a novel role in thrombus aspiration and intracoronary medication delivery.
Braun, Ulrike; Lorenz, Edelgard; Weimann, Christiane; Sturm, Heinz; Karimov, Ilham; Ettl, Johannes; Meier, Reinhard; Wohlgemuth, Walter A; Berger, Hermann; Wildgruber, Moritz
2016-12-01
Central venous port devices made of two different polymeric materials, thermoplastic polyurethane (TPU) and silicone rubber (SiR), were compared due their material properties. Both naïve catheters as well as catheters after removal from patients were investigated. In lab experiments the influence of various chemo-therapeutic solutions on material properties was investigated, whereas the samples after removal were compared according to the implanted time in patient. The macroscopic, mechanical performance was assessed with dynamic, specially adapted tests for elasticity. The degradation status of the materials was determined with common tools of polymer characterisation, such as infrared spectroscopy, molecular weight measurements and various methods of thermal analysis. The surface morphology was analysed using scanning electron microscopy. A correlation between material properties and clinical performance was proposed. The surface morphology and chemical composition of the polyurethane catheter materials can potentially result in increased susceptibility of the catheter to bloodstream infections and thrombotic complications. The higher mechanic failure, especially with increasing implantation time of the silicone catheters is related to the lower mechanical performance compared to the polyurethane material as well as loss of barium sulphate filler particles near the surface of the catheter. This results in preformed microscopic notches, which act as predetermined sites of fracture. Copyright © 2016 Elsevier Ltd. All rights reserved.
Comparison of three chronic dialysis models.
Peng, W X; Guo, Q Y; Liu, S M; Liu, C Z; Lindholm, B; Wang, T
2000-01-01
The chronic peritoneal dialysis model is important for understanding the pathophysiology of peritoneal transport and for studying biocompatibility of peritoneal dialysis solutions. In this study, we compared three different chronic peritoneal dialysis models. A peritoneal catheter was placed in 23 male Sprague-Dawley rats, 12 of which had an intact omentum (model 1) and 11 of which received an omentectomy (model 2). Seven other rats, without a catheter, received a daily intraperitoneal injection (model 3). Each rat received a daily infusion of 25 mL of 3.86% glucose dialysis solution either through the catheter (models 1 and 2) or through injection (model 3) for 4 weeks. Then, a 4-hour dwell study using 3.86% glucose solution with an intraperitoneal volume marker and frequent dialysate and blood sampling was performed in each rat. The intraperitoneal volume was significantly lower in all the dialysis groups as compared to a control group (n = 6) in which the rats had no chronic dialysate exposure. The peritoneal fluid absorption rate, as well as the direct lymphatic absorption rate, was significantly higher in the three dialysis groups as compared to the control group. In general, no significant differences were seen in any of the parameters among the three dialysis models. Owing to catheter obstruction, three rats in model 1 and four rats in model 2 were lost during dialysis. Histological examination showed no significant differences among the three dialysis groups. Our results suggest that omentectomy may not be necessary in the chronic peritoneal dialysis model when using dialysate infusion and no drainage. Based on the present study, we think that perhaps model 1 may be the method of choice to test new peritoneal dialysis solutions. However, owing to its simplicity, model 3 could also be used if great care is taken to avoid puncturing the intestine or injecting into the abdominal wall.
Bastings, Maartje M C; Koudstaal, Stefan; Kieltyka, Roxanne E; Nakano, Yoko; Pape, A C H; Feyen, Dries A M; van Slochteren, Frebus J; Doevendans, Pieter A; Sluijter, Joost P G; Meijer, E W; Chamuleau, Steven A J; Dankers, Patricia Y W
2014-01-01
Minimally invasive intervention strategies after myocardial infarction use state-of-the-art catheter systems that are able to combine mapping of the infarcted area with precise, local injection of drugs. To this end, catheter delivery of drugs that are not immediately pumped out of the heart is still challenging, and requires a carrier matrix that in the solution state can be injected through a long catheter, and instantaneously gelates at the site of injection. To address this unmet need, a pH-switchable supramolecular hydrogel is developed. The supramolecular hydrogel is switched into a liquid at pH > 8.5, with a viscosity low enough to enable passage through a 1-m long catheter while rapidly forming a hydrogel in contact with tissue. The hydrogel has self-healing properties taking care of adjustment to the injection site. Growth factors are delivered from the hydrogel thereby clearly showing a reduction of infarct scar in a pig myocardial infarction model. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Dynamics of temporally localized states in passively mode-locked semiconductor lasers
NASA Astrophysics Data System (ADS)
Schelte, C.; Javaloyes, J.; Gurevich, S. V.
2018-05-01
We study the emergence and the stability of temporally localized structures in the output of a semiconductor laser passively mode locked by a saturable absorber in the long-cavity regime. For large yet realistic values of the linewidth enhancement factor, we disclose the existence of secondary dynamical instabilities where the pulses develop regular and subsequent irregular temporal oscillations. By a detailed bifurcation analysis we show that additional solution branches that consist of multipulse (molecules) solutions exist. We demonstrate that the various solution curves for the single and multipeak pulses can splice and intersect each other via transcritical bifurcations, leading to a complex web of solutions. Our analysis is based on a generic model of mode locking that consists of a time-delayed dynamical system, but also on a much more numerically efficient, yet approximate, partial differential equation. We compare the results of the bifurcation analysis of both models in order to assess up to which point the two approaches are equivalent. We conclude our analysis by the study of the influence of group velocity dispersion, which is only possible in the framework of the partial differential equation model, and we show that it may have a profound impact on the dynamics of the localized states.
Omotani, Sachiko; Tani, Katsuji; Nagai, Katsuhito; Hatsuda, Yasutoshi; Mukai, Junji; Myotoku, Michiaki
2017-01-01
Peripheral parenteral nutrition (PPN) solutions contain amino acids, glucose, and electrolytes, with or without some water soluble vitamins. Peripheral venous catheters are one of the causes of catheter related blood stream infection (CRBSI), which requires infection control. In Japan, PPN solutions have rarely been prepared under aseptic conditions. However, in recent years, the necessity of adding vitamins to infusions has been reported. Therefore, we investigated the effects of water soluble vitamins on growth of microorganisms in PPN solutions. AMINOFLUID ® (AF), BFLUID ® (BF), PARESAFE ® (PS) and PAREPLUS ® (PP) PPN solutions were used. Water soluble vitamins contained in PP were also used. Causative microorganisms of CRBSI were used. Staphylococcus epidermidis decreased after 24 hours or 48 hours in all solutions. On the other hand, Escherichia coli , Serratia marcescens , Pseudomonas aeruginosa, Staphylococcus aureus and Candida albicans increased, especially in PP. When each water soluble vitamin was added to BF and PS, growth of S. aureus was greater in solutions that contained nicotinamide than in solutions that contained other vitamins. As for C. albicans , they grew in all test solutions. C. albicans grew especially well in solutions that contained biotin. When commercial amino acids and glucose solutions with electrolytes are administered, in particular those containing multivitamins or water soluble vitamins, efforts to control infection must be taken to prevent proliferation of microorganisms.
Research of improved banker algorithm
NASA Astrophysics Data System (ADS)
Yuan, Xingde; Xu, Hong; Qiao, Shijiao
2013-03-01
In the multi-process operating system, resource management strategy of system is a critical global issue, especially when many processes implicating for the limited resources, since unreasonable scheduling will cause dead lock. The most classical solution for dead lock question is the banker algorithm; however, it has its own deficiency and only can avoid dead lock occurring in a certain extent. This article aims at reducing unnecessary safety checking, and then uses the new allocation strategy to improve the banker algorithm. Through full analysis and example verification of the new allocation strategy, the results show the improved banker algorithm obtains substantial increase in performance.
Dettenkofer, M; Wilson, C; Gratwohl, A; Schmoor, C; Bertz, H; Frei, R; Heim, D; Luft, D; Schulz, S; Widmer, A F
2010-06-01
To compare the efficacy of two commercially available, alcohol-based antiseptic solutions for preparation and care of central venous catheter (CVC) insertion sites, with and without octenidine dihydrochloride, a double-blind, randomized, controlled trial was undertaken in the haematology units and in one surgical unit of two university hospitals. Adult patients with a non-tunnelled CVC were randomly assigned to two different skin disinfection regimens at the insertion site: 0.1% octenidine with 30% 1-propanol and 45% 2-propanol, and as control 74% ethanol with 10% 2-propanol. Endpoints were (i) skin colonization at the insertion site; (ii) positive culture from the catheter tip (> or = 15 CFU); and (iii) occurrence of CVC-associated bloodstream infection (defined according to criteria set by the CDC). Four hundred patients with inserted CVC were enrolled from May 2002 through April 2005. Both groups were similar in respect of patient characteristics and co-morbidities. Skin colonization at the CVC insertion site during the first 10 days was significantly reduced by octenidine treatment (relative difference octenidine vs. control: 0.21; 95%CI: 0.11-0.39, p <0.0001). Positive culture of the catheter tip was significantly less frequent in the octenidine group (7.9%) than in the control group (17.8%): OR = 0.39 (95%CI: 0.20-0.80, p 0.009). Patients treated with octenidine had a non-significant reduction in catheter-associated bloodstream infections (4.1% vs. 8.3%; OR = 0.44; 95%CI: 0.18-1.08, p 0.081). Side effects were similar in both groups. This randomized controlled trial supports the results of two observational studies demonstrating octenidine in alcoholic solution to be a better option than alcohol alone for the prevention of CVC-associated infections.
Hanak, Brian W; Ross, Emily F; Harris, Carolyn A; Browd, Samuel R; Shain, William
2016-08-01
OBJECTIVE Shunt obstruction by cells and/or tissue is the most common cause of shunt failure. Ventricular catheter obstruction alone accounts for more than 50% of shunt failures in pediatric patients. The authors sought to systematically collect explanted ventricular catheters from the Seattle Children's Hospital with a focus on elucidating the cellular mechanisms underlying obstruction. METHODS In the operating room, explanted hardware was placed in 4% paraformaldehyde. Weekly, samples were transferred to buffer solution and stored at 4°C. After consent was obtained for their use, catheters were labeled using cell-specific markers for astrocytes (glial fibrillary acidic protein), microglia (ionized calcium-binding adapter molecule 1), and choroid plexus (transthyretin) in conjunction with a nuclear stain (Hoechst). Catheters were mounted in custom polycarbonate imaging chambers. Three-dimensional, multispectral, spinning-disk confocal microscopy was used to image catheter cerebrospinal fluid-intake holes (10× objective, 499.2-μm-thick z-stack, 2.4-μm step size, Olympus IX81 inverted microscope with motorized stage and charge-coupled device camera). Values are reported as the mean ± standard error of the mean and were compared using a 2-tailed Mann-Whitney U-test. Significance was defined at p < 0.05. RESULTS Thirty-six ventricular catheters have been imaged to date, resulting in the following observations: 1) Astrocytes and microglia are the dominant cell types bound directly to catheter surfaces; 2) cellular binding to catheters is ubiquitous even if no grossly visible tissue is apparent; and 3) immunohistochemical techniques are of limited utility when a catheter has been exposed to Bugbee wire electrocautery. Statistical analysis of 24 catheters was performed, after excluding 7 catheters exposed to Bugbee wire cautery, 3 that were poorly fixed, and 2 that demonstrated pronounced autofluorescence. This analysis revealed that catheters with a microglia-dominant cellular response tended to be implanted for shorter durations (24.7 ± 6.7 days) than those with an astrocyte-dominant response (1183 ± 642 days; p = 0.027). CONCLUSIONS Ventricular catheter occlusion remains a significant source of shunt morbidity in the pediatric population, and given their ability to intimately associate with catheter surfaces, astrocytes and microglia appear to be critical to this pathophysiology. Microglia tend to be the dominant cell type on catheters implanted for less than 2 months, while astrocytes tend to be the most prevalent cell type on catheters implanted for longer time courses and are noted to serve as an interface for the secondary attachment of ependymal cells and choroid plexus.
The locking and unlocking thresholds for tearing modes in a cylindrical tokamak
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Wenlong; Zhu, Ping, E-mail: pzhu@ustc.edu.cn; Department of Engineering Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706
2016-03-15
The locking and unlocking thresholds for tearing modes are in general different. In this work, the physics origin for this difference is illustrated from theory analysis, and a numerical procedure is developed to find both locking and unlocking thresholds. In particular, a new scaling law for the unlocking threshold that is valid in both weak and strong rotation regimes has been derived from the lowest amplitude of the RMP (resonant magnetic perturbation) allowed for the locked-mode solution. Above the unlocking threshold, the criterion for the phase-flip instability is extended to identify the entire locked-mode states. Two different regimes of themore » RMP amplitude in terms of the accessibility of the locked-mode states have been found. In the first regime, the locked-mode state may or may not be accessible depending on the initial conditions of an evolving island. In the second regime, the locked-mode state can always be reached regardless of the initial conditions of the tearing mode. The lowest RMP amplitude for the second regime is determined to be the mode-locking threshold. The different characteristics of the two regimes above the unlocking threshold reveal the underlying physics for the gap between the locking and unlocking thresholds and provide an explanation for the closely related and widely observed hysteresis phenomena in island evolution during the sweeping process of the RMP amplitude up and down across that threshold gap.« less
Liu, Zhi-Bo; He, Xiaoying; Wang, D N
2011-08-15
We demonstrate a nanosecond-pulse erbium-doped fiber laser that is passively mode locked by a hollow-core photonic crystal fiber filled with few-layered graphene oxide solution. Owing to the good solution processing capability of few-layered graphene oxide, which can be filled into the core of a hollow-core photonic crystal fiber through a selective hole filling process, a graphene saturable absorber can be successfully fabricated. The output pulses obtained have a center wavelength, pulse width, and repetition rate of 1561.2 nm, 4.85 ns, and 7.68 MHz, respectively. This method provides a simple and efficient approach to integrate the graphene into the optical fiber system. © 2011 Optical Society of America
2010-05-01
allows task submission to be decoupled from low-level scheduling and thread management details. It provides the thread pool mechanism that allows a...resource management . In this compliant solution, the client’s doSomething() method provides only the required func- tionality by implementing the...doSomethingWithFile() method of the LockAction inter- face, without having to manage the acquisition and release of locks or the open and close opera
Gröbner, Sabine; Heeg, Peter; Autenrieth, Ingo B; Schulte, Berit
2007-12-01
Ralstonia mannitolilytica is a non-fermentative, gram-negative bacterium isolated infrequently from clinical samples. However, within a period of 11 weeks five inpatients of the tertiary care hospital of the University of Tübingen developed clinical signs of infection and R. mannitolilytica was cultivated from blood samples of all patients suggesting an outbreak. Blood cultures and one catheter tip were analysed by standard microbiological procedures. Genetic relatedness of the isolates was investigated by pulsed-field gel electrophoresis. To ascertain the possible source of the outbreak, environmental sampling and challenge-recovery experiments to test filters used for multi-dose solution bottles were performed. In the present study a monoclonal outbreak with R. mannitolilytica causing catheter-related infection of five haematological patients is reported. Underlying severe diseases with consecutive immunosuppression, permanent indwelling intravenous devices, multiple intravenous applications, and chemotherapy were possible risk factors promoting the infection. Challenge-recovery experiments revealed that R. mannitolilytica to a high extent even passed through Mini-spike Plus filters of pore size 0.2 microm. Although the source of the outbreak could not be identified, it is possible that solutions given intravenously were contaminated. Since R. mannitolilytica had never been isolated in our laboratory before and environmental testings performed were negative, it cannot be excluded that commercial products like drugs, saline solutions or infusion systems (filters) were contaminated.
Influence of Double-J Catheters on Urinary Infections After Kidney Transplantation.
Jonas, M; Jóźwik, A; Kawecki, D; Durlik, M; Pączek, L; Młynarczyk, G; Chmura, A
2016-06-01
One of the most important problem in kidney transplantation is risk of the urinary anastomosis stricture. In uncertain cases the use of a double-J (or JJ) catheter is a standard solution. In case of urinary leak or fistula after the reanastomosis operation, transuretheral JJ implantation is used. A number of patients after JJ use present urinary infection. Between 2012 and 2014, 283 kidney transplantations were performed in our center. In 77 cases (27.2%), a JJ was used at the time of operation, in 10 other cases (3.5%) during postoperative period. Urinary infection was observed in 95 patients (33.6%), with Proteus, Klebsiella, Enterobacter, Escherichia, Enterococcus, Pseudomonas, Morganella, and Staphylococcus cultures. In the group of patients without JJ catheters, infections were found in 27.6% of cases and in group with JJ, in 47.1% (46.8% in intraoperative use of catheters and 50% in postoperative curse). The analysis shows that use of JJ catheters gives urinary infections almost twice more frequent (47.1% vs 27.6%; P = .001) with no difference if the implantation took place during or after the operation. Copyright © 2016. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Ortega-Robles, Emmanuel; Cruz-Orea, Alfredo; Elías-Viñas, David
2018-03-01
The lock-in amplifier is a very useful instrument for observing very small signals under adverse signal-to-noise conditions. In this work, we describe a simple and portable lock-in amplifier designed to be used in photoacoustic measurements. The device was used to measure the thermal effusivity of eight different liquid samples (distilled water, glycerol, acetone, ethanol, 2-propanol, chloroform, hexane, and methanol), as well as the effusivity of acetone in aqueous solution at distinct concentrations, giving good results. The instrument has a bandwidth of 10 Hz-10 kHz and a sensitivity of 1 μV.
NASA Technical Reports Server (NTRS)
Yariv, A.
1972-01-01
A theoretical investigation revealed that a steady state mode-locked solution appropriate to ultrashort pulses is induced by Kerr liquids. An experimental investigation using a Q-switched ruby laser passively mode-locked by the insertion of a Kerr liquid verified the theory. Pulses of about 10 to the -11th power sec were generated when the relaxation time of the liquid was temperature tuned to approximately 10 to the -11th power sec.
Peripheral Venous Access Ports: Outcomes Analysis in 109 Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bodner, Leonard J.; Nosher, John L.; Patel, Kaushik M.
Purpose: To perform a retrospective outcomes analysis of central venous catheters with peripheral venous access ports, with comparison to published data.Methods: One hundred and twelve central venous catheters with peripherally placed access ports were placed under sonographic guidance in 109 patients over a 4-year period. Ports were placed for the administration of chemotherapy, hyperalimentation, long-term antibiotic therapy, gamma-globulin therapy, and frequent blood sampling. A vein in the upper arm was accessed in each case and the catheter was passed to the superior vena cava or right atrium. Povidone iodine skin preparation was used in the first 65 port insertions. Amore » combination of Iodophor solution and povidone iodine solution was used in the last 47 port insertions. Forty patients received low-dose (1 mg) warfarin sodium beginning the day after port insertion. Three patients received higher doses of warfarin sodium for preexistent venous thrombosis. Catheter performance and complications were assessed and compared with published data.Results: Access into the basilic or brachial veins was obtained in all cases. Ports remained functional for a total of 28,936 patient days. The port functioned in 50% of patients until completion of therapy, or the patient's expiration. Ports were removed prior to completion of therapy in 18% of patients. Eleven patients (9.9% of ports placed) suffered an infectious complication (0.38 per thousand catheter-days)-in nine, at the port implantation site, in two along the catheter. In all 11 instances the port was removed. Port pocket infection in the early postoperative period occurred in three patients (4.7%) receiving a Betadine prep vs two patients (4.2%) receiving a standard O.R. prep. This difference was not statistically significant (p = 0.9). Venous thrombosis occurred in three patients (6.8%) receiving warfarin sodium and in two patients (3%) not receiving warfarin sodium. This difference was not statistically significant (p = 0.6). Aspiration occlusion occurred in 13 patients (11.7%). Intracatheter urokinase was infused in eight of these patients and successfully restored catheter function in all but two instances. These complication rates are comparable to or better than those reported with chest ports.Conclusion: Peripheral ports for long-term central venous access placed by interventional radiologists in the interventional radiology suite are as safe and as effective as chest ports.« less
Wo, Yaqi; Li, Zi; Colletta, Alessandro; Wu, Jianfeng; Xi, Chuanwu; Matzger, Adam J; Brisbois, Elizabeth J; Bartlett, Robert H; Meyerhoff, Mark E
2017-07-15
Stable and long-term nitric oxide (NO) releasing polymeric materials have many potential biomedical applications. Herein, we report the real-time observation of the crystallization process of the NO donor, S -nitroso- N -acetylpenicillamine (SNAP), within a thermoplastic silicone-polycarbonate-urethane biomedical polymer, CarboSil 20 80A. It is demonstrated that the NO release rate from this composite material is directly correlated with the surface area that the CarboSil polymer film is exposed to when in contact with aqueous solution. The decomposition of SNAP in solution (e.g. PBS, ethanol, THF, etc.) is a pseudo-first-order reaction proportional to the SNAP concentration. Further, catheters fabricated with this novel NO releasing composite material are shown to exhibit significant effects on preventing biofilm formation on catheter surface by Pseudomonas aeruginosa and Proteus mirabilis grown in CDC bioreactor over 14 days, with a 2 and 3 log-unit reduction in number of live bacteria on their surfaces, respectively. Therefore, the SNAP-CarboSil composite is a promising new material to develop antimicrobial catheters, as well as other biomedical devices.
Lyons, Margaret G; Phalen, Ann G
2014-01-01
Research has failed to demonstrate an optimal flushing solution or frequency for central catheters. In a 2002 study of 50 000 home care patients, catheter dysfunction with loss of patency was the most common complication and occurred in 29% of the peripherally inserted central catheters (PICCs) tracked. With the advent of the Affordable Care Act and the promise of expanded home care services, this study offers evidence as to a preferred flushing protocol to prevent catheter patency complications for home infusion patients with PICCs. This prospective, randomized, 1-way, single-blinded posttest with control group study was performed to compare 3 commonly used flushing protocols in home infusion patients with PICCs. The independent variable was the flushing protocol, and dependent variables included the development of patency-related complications and other significant issues such as sluggishness, occlusion, missed medication doses, catheter replacement, additional nursing visits, and the use of alteplase (Cathflo Activase). Each of the study groups had patients who experienced 1 or more patency-related complications. Additional factors that may affect catheter function, including patient age, gender, diagnosis, therapy type, frequency of catheter use, catheter brand/size/number of lumens, concomitant use of anticoagulant medications, and whether PICCs were used for routine lab testing, were analyzed, and no statistical significance was determined. Catheter dwell time (catheter days) was statistically significant (p = .003, confidence interval = 95%; assuming equal variance) and confirmed the assumption that the longer a home care patient's catheter was in place, the more complications occurred. There were no cases of heparin allergy, heparin-induced thrombocytopenia, or line infection. The data provide some evidence to support the elimination of heparin flushing in home care patients with PICCs, although data in the saline-only group that related to additional registered nurse visits to assess PICC patency and the use of alteplase (Cathflo Activase) were trending toward significance because this group experienced a higher incidence of these complications than both the heparin groups. These findings should not be translated to home care patients with cancer or pregnancy diagnoses because these populations were excluded from this study. More studies of this topic area should be initiated. Please see video abstract, Supplemental Digital Content 1, for more information (http://links.lww.com/JIN/A3).
[Biodegradable catheters and urinary stents. When?
Soria, F; Morcillo, E; López de Alda, A; Pastor, T; Sánchez-Margallo, F M
2016-10-01
One of the main wishes in the field of urinary catheters and stents is to arm them with biodegradable characteristics because we consider a failure of these devices the need for retrieval, the forgotten catheter syndrome as well as the adverse effects permanent devices cause after fulfilling their aim. The efforts focused in new designs, coatings and biomaterials aim to increase the biocompatibility of theses internal devices. Lately, there have been correct advances to answer the main challenges regarding biodegradable ureteral devices. Thus, modulation of the rate of degradation has been achieved thanks to new biomaterials and the use of copolymers that enable to choose the time of permanence as it is programmed with conventional double J catheters. Biocompatibility has improved with the use of new polymers that adapt better to the urine. Finally, one of the main problems is elimination of degraded fragments and experimentally it has be demonstrated that new designs elicit controlled degradation, from distal to proximal; using stranding and combination of copolymers degradation may be caused by dilution, reducing fragmentation to the last stages of life of the prosthesis. Moreover, it has been demonstrated that biodegradable catheters potentially may cause less urinary tract infection, less encrustation and predictably they will diminish catheter morbidity, since their degradation process reduces adverse effects. Regarding the development of biodegradable urethral stents, it is necessary to find biomaterials that enable maintaining their biomechanical properties in the long term, keeping open the urethral lumen both in patients with BPH and urethral stenosis. Modulation of the time of degradation of the prosthesis has been achieved, but the appearance of urothelial hyperplasia is still a constant in the initial phases after implantation. The development of drug eluting stents, anti-proliferative or anti-inflammatory, as well as biodegradable stents biocoated is a field from which it is expected the arrival of the solution of theses adverse effects. Therefore, many features need to be improved to obtain biodegradable stents, but over the last years some turning points have been accomplished thanks to the advances in Bioengineering, allowing to foresee safe and effective solutions in the nearest future.
Bladder irrigation in patients with indwelling catheters.
Bruun, J N; Digranes, A
1978-01-01
The effect of intermittent bladder irrigation on the bacterial counts in urine samples was studied in patients with indwelling catheter and pre-existing urinary tract infection. Four different irrigating solutions were used. Irrigation with saline or 0.25% acetic acid had no effect on the urinary bacterial count. The bacterial counts were effectively reduced during intermittent irrigation both with 0.02% chlorhexidine and with 0.25% silver nitrate. Silver nitrate gave the greatest reduction of bacterial counts but chlorhexidine is preferable due to fewer side effects and greater convenience.
Personal Computer System for Automatic Coronary Venous Flow Measurement
Dew, Robert B.
1985-01-01
We developed an automated system based on an IBM PC/XT Personal computer to measure coronary venous blood flow during cardiac catheterization. Flow is determined by a thermodilution technique in which a cold saline solution is infused through a catheter into the coronary venous system. Regional temperature fluctuations sensed by the catheter are used to determine great cardiac vein and coronary sinus blood flow. The computer system replaces manual methods of acquiring and analyzing temperature data related to flow measurement, thereby increasing the speed and accuracy with which repetitive flow determinations can be made.
Kuramoto model with uniformly spaced frequencies: Finite-N asymptotics of the locking threshold.
Ottino-Löffler, Bertrand; Strogatz, Steven H
2016-06-01
We study phase locking in the Kuramoto model of coupled oscillators in the special case where the number of oscillators, N, is large but finite, and the oscillators' natural frequencies are evenly spaced on a given interval. In this case, stable phase-locked solutions are known to exist if and only if the frequency interval is narrower than a certain critical width, called the locking threshold. For infinite N, the exact value of the locking threshold was calculated 30 years ago; however, the leading corrections to it for finite N have remained unsolved analytically. Here we derive an asymptotic formula for the locking threshold when N≫1. The leading correction to the infinite-N result scales like either N^{-3/2} or N^{-1}, depending on whether the frequencies are evenly spaced according to a midpoint rule or an end-point rule. These scaling laws agree with numerical results obtained by Pazó [D. Pazó, Phys. Rev. E 72, 046211 (2005)PLEEE81539-375510.1103/PhysRevE.72.046211]. Moreover, our analysis yields the exact prefactors in the scaling laws, which also match the numerics.
The lock-in effect and the greening of automotive cooling systems in the European Union.
Bjørnåvold, Amalie; Van Passel, Steven
2017-12-01
As of 2017, the sale and use of the refrigerants most commonly used in automotive cooling systems - hydrofluorocarbons - are entirely banned in all new vehicles placed on the market in the European Union. These refrigerants have been recognised as potent greenhouse gases and, therefore, direct contributors to climate change. It is within this regulation-driven market that the technologies for a sustainable solution have been developed. However, this paper argues that the market for automotive cooling systems has been 'locked-in', which means that competing technologies, operating under dynamic increasing returns, will allow for one - potentially inferior technology - to dominate the market. Whilst such a situation is not uncommon, this paper discusses the way that regulation has reinforced a patented monopoly in 'picking winners': to the advantage of a synthetic chemical, R-1234yf, as opposed to the natural solution, which is CO 2 . By developing a generic conceptual framework of path dependence and lock-in, the presented evidence seeks to show how a snowballing effect has led to the intensification of differences in market share. We also argue that the automotive industry is potentially promoting short-term fixes, rather than long-term, sustainable and economically viable solutions. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Boitier, V.; Durand Estèbe, P.; Monthéard, R.; Bafleur, M.; Dilhac, J. M.
2013-12-01
This paper deals with the issue of the initial start-up of an autonomous and battery-free system powered by an energy harvester associated with a storage subsystem based on supercapacitors initially discharged. A review of different low power Under Voltage Lock-Out (UVLO) solutions used to delay the load start-up and to avoid a useless discharge of supercapacitors is presented and discussed.
Integrated HIFU Drive System on a Chip for CMUT-Based Catheter Ablation System.
Farhanieh, Omid; Sahafi, Ali; Bardhan Roy, Rupak; Ergun, Arif Sanli; Bozkurt, Ayhan
2017-06-01
Conventional High Intensity Focused Ultrasound (HIFU) is a therapeutic modality which is extracorporeally administered. In applications where a relatively small HIFU lesion is required, an intravascular HIFU probe can be deployed to the ablation site. In this paper, we demonstrate the design and implementation a fully integrated HIFU drive system on a chip to be placed on a 6 Fr catheter probe. An 8-element capacitive micromachined ultrasound transducer (CMUT) ring array of 2 mm diameter has been used as the ultrasound source. The driver chip is fabricated in 0.35 μm AMS high-voltage CMOS technology and comprises eight continuous-wave (CW) high-voltage CMUT drivers (10.9 ns and 9.4 ns rise and fall times at 20 V pp output into a 15 pF), an eight-channel digital beamformer (8-12 MHz output frequency with 11.25 ° phase accuracy) and a phase locked loop with an integrated VCO as a tunable clock source (128-192 MHz). The chip occupies 1.85 × 1.8 mm 2 area including input and output (I/O) pads. When the transducer array is immersed in sunflower oil and driven by the IC with eight 20 V pp CW pulses at 10 MHz, real-time thermal images of the HIFU beam indicate that the focal temperature rises by 16.8 ° C in 11 seconds. Each HV driver consumes around 67 mW of power when driving the CMUT array at 10 MHz, which adds up to 560 mW for the whole chip. FEM based analysis reveals that the outer surface temperature of the catheter is expected to remain below the 42 ° C tissue damage limit during therapy.
Peripherally inserted central catheter - dressing change
... chlorhexidine) in a single-use small applicator Special sponges or wipes that contain a cleaning agent, such ... Clean your skin around the site with the sponge and cleaning solution for 30 seconds. Let the ...
Tuncali, Binnur E; Kuvaki, Buhar; Tuncali, Bahattin; Capar, Emine
2005-04-01
In a randomized, double-blind, controlled study, we compared heparinized and nonheparinized infusions for the maintenance of perioperative arterial catheter patency and the incidence of subsequent radial arterial occlusion. Two-hundred patients were randomized into 2 groups to receive heparinized (group H, n = 100) or nonheparinized (group S, n = 100) flush solutions. Radial and ulnar blood flows were assessed using Doppler probe and pulse oximetry before, just after, and 24 h after decannulation by the same investigator. The cannulation site was examined for complications such as hematoma, nerve injury, and infection. The mean duration of cannulations was 378 +/- 159.0 min in group H and 332 +/- 154.6 min in group S. The mean number of corrective interventions caused by dampening of the pressure wave (mean number of positional changes [group S, 1.5 +/- 2.0; group H, 1.4 +/- 3.8] and mean number of manual flushes [group S, 1.3 +/- 1.7; group H, 1.2 +/- 1.2]) was not significantly different in both groups. After decannulation, partial or total occlusion developed in 20 group H patients and 16 group S patients (not significant). The incidence of occlusion was correlated to the presence of hematoma at the puncture site after decannulation (P = 0.013), long duration of cannulation (P = 0.04), and age <65 yr (P = 0.009). In conclusion, there is no significant difference between heparinized and nonheparinized flush solutions for the maintenance of perioperative radial artery catheter patency.
Scalar-vector soliton fiber laser mode-locked by nonlinear polarization rotation.
Wu, Zhichao; Liu, Deming; Fu, Songnian; Li, Lei; Tang, Ming; Zhao, Luming
2016-08-08
We report a passively mode-locked fiber laser by nonlinear polarization rotation (NPR), where both vector and scalar soliton can co-exist within the laser cavity. The mode-locked pulse evolves as a vector soliton in the strong birefringent segment and is transformed into a regular scalar soliton after the polarizer within the laser cavity. The existence of solutions in a polarization-dependent cavity comprising a periodic combination of two distinct nonlinear waves is first demonstrated and likely to be applicable to various other nonlinear systems. For very large local birefringence, our laser approaches the operation regime of vector soliton lasers, while it approaches scalar soliton fiber lasers under the condition of very small birefringence.
Verification of intravenous catheter placement by auscultation--a simple, noninvasive technique.
Lehavi, Amit; Rudich, Utay; Schechtman, Moshe; Katz, Yeshayahu Shai
2014-01-01
Verification of proper placement of an intravenous catheter may not always be simple. We evaluated the auscultation technique for this purpose. Twenty healthy volunteers were randomized for 18G catheter inserted intravenously either in the right (12) or left arm (8), and subcutaneously in the opposite arm. A standard stethoscope was placed over an area approximately 3 cm proximal to the tip of the catheter in the presumed direction of the vein to grade on a 0-6 scale the murmur heard by rapidly injecting 2 mL of NaCl 0.9% solution. The auscultation was evaluated by a blinded staff anesthesiologist. All 20 intravenous injection were evaluated as flow murmurs, and were graded an average 5.65 (±0.98), whereas all 20 subcutaneous injections were evaluated as either crackles or no sound, and were graded an average 2.00 (±1.38), without negative results. Sensitivity was calculated as 95%. Specificity and Kappa could not be calculated due to an empty false-positive group. Being simple, handy and noninvasive, we recommend to use the auscultation technique for verification of the proper placement of an intravenous catheter when uncertain of its position. Data obtained in our limited sample of healthy subjects need to be confirmed in the clinical setting.
Factors confounding impedance catheter volume measurements in vitro.
Bielefeld, M R; Cabreriza, S E; Spotnitz, H M
1993-06-01
The impedance catheter allows continuous measurement of ventricular volume. External influences have been described as causing parallel shifts in impedance-measured volumes; however, factors affecting impedance measurements in a nonparallel manner have not been fully characterized. Accordingly, an impedance catheter was placed inside a latex balloon into which known volumes of normal saline solution were injected. Conductive and nonconductive materials were individually placed within the balloon. Impedance was measured with materials touching (T) or not touching (NT) the catheter. Impedance-measured volumes were plotted versus actual volumes. Compared with the line of identity (LID), a statistical difference (p < 0.05) was found in the slopes in the presence of metallic objects only. These included a pacing lead (T, NT) (mT = 1.32m mNT = 1.29 versus mLID = 1.00), titanium (T) (mT = 1.68 versus mLID = 1.00), and aluminum (NT) (mNT = 0.72 versus mLID = 1.00). These changes in slope indicate nonparallel effects on impedance that confound the ability of the impedance catheter to determine volumes in vitro. These observations imply that serial calibration of both the slope constant (alpha) and the intercept (parallel conductance) of impedance may be necessary for in vivo measurements of ventricular volume based on impedance in the presence of metallic objects.
Flexible robotic catheters in the visceral segment of the aorta: advantages and limitations.
Li, Mimi M; Hamady, Mohamad S; Bicknell, Colin D; Riga, Celia V
2018-06-01
Flexible robotic catheters are an emerging technology which provide an elegant solution to the challenges of conventional endovascular intervention. Originally developed for interventional cardiology and electrophysiology procedures, remotely steerable robotic catheters such as the Magellan system enable greater precision and enhanced stability during target vessel navigation. These technical advantages facilitate improved treatment of disease in the arterial tree, as well as allowing execution of otherwise unfeasible procedures. Occupational radiation exposure is an emerging concern with the use of increasingly complex endovascular interventions. The robotic systems offer an added benefit of radiation reduction, as the operator is seated away from the radiation source during manipulation of the catheter. Pre-clinical studies have demonstrated reduction in force and frequency of vessel wall contact, resulting in reduced tissue trauma, as well as improved procedural times. Both safety and feasibility have been demonstrated in early clinical reports, with the first robot-assisted fenestrated endovascular aortic repair in 2013. Following from this, the Magellan system has been used to successfully undertake a variety of complex aortic procedures, including fenestrated/branched endovascular aortic repair, embolization, and angioplasty.
2017-01-01
Nitric oxide (NO) has many important physiological functions, including its ability to inhibit platelet activation and serve as potent antimicrobial agent. The multiple roles of NO in vivo have led to great interest in the development of biomaterials that can deliver NO for specific biomedical applications. Herein, we report a simple solvent impregnation technique to incorporate a nontoxic NO donor, S-nitroso-N-acetylpenicillamine (SNAP), into a more biocompatible biomedical grade polymer, CarboSil 20 80A. The resulting polymer-crystal composite material yields a very stable, long-term NO release biomaterial. The SNAP impregnation process is carefully characterized and optimized, and it is shown that SNAP crystal formation occurs in the bulk of the polymer after solvent evaporation. LC-MS results demonstrate that more than 70% of NO release from this new composite material originates from the SNAP embedded CarboSil phase, and not from the SNAP species leaching out into the soaking solution. Catheters prepared with CarboSil and then impregnated with 15 wt % SNAP provide a controlled NO release over a 14 d period at physiologically relevant fluxes and are shown to significantly reduce long-term (14 day) bacterial biofilm formation against Staphylococcus epidermidis and Pseudonomas aeruginosa in a CDC bioreactor model. After 7 h of catheter implantation in the jugular veins of rabbit, the SNAP CarboSil catheters exhibit a 96% reduction in thrombus area (0.03 ± 0.01 cm2/catheter) compared to the controls (0.84 ± 0.19 cm2/catheter) (n = 3). These results suggest that SNAP impregnated CarboSil can become an attractive new biomaterial for use in preparing intravascular catheters and other implanted medical devices. PMID:28317023
Miyasaka, Masaki; Tada, Norio; Kato, Shigeaki; Kami, Masahiro; Horie, Kazunori; Honda, Taku; Takizawa, Kaname; Otomo, Tatsushi; Inoue, Naoto
2016-05-01
The aim of this study was to assess the safety and efficacy of sheathless guide catheters in transradial percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI). Transradial PCI for STEMI offers significant clinical benefits, including a reduced incidence of vascular complications. As the size of the radial artery is small, the radial artery is frequently damaged in this procedure using large-bore catheters. A sheathless guide catheter offers a solution to this problem as it does not require an introducer sheath. However, the efficacy and safety of sheathless guide catheters remain to be fully determined in emergent transradial PCI for STEMI. Data on consecutive STEMI patients undergoing primary PCI at the Sendai Kousei Hospital between September 2010 and May 2013 were analyzed. The primary endpoint was the rate of acute procedural success without access site crossover. Secondary endpoints included door-to-balloon time, fluoroscopy time, volume of contrast, and radial artery stenosis or occlusion rate. We conducted transradial PCI for 478 patients with STEMI using a sheathless guide catheter. Acute procedural success was achieved in 466 patients (97.5%). The median door-to-balloon time was 45 min (range, 15-317 min). The median fluoroscopy time was 16.4 min (range, 10-90 min). The median volume of contrast was 134 mL (range, 31-431 mL). Radial stenosis or occlusion developed in 14 (3.8%) of the 370 evaluable patients. This study showed that use of a sheathless guide catheter taking a transradial approach was effective and safe in primary PCI for STEMI. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Microfabricated therapeutic actuators
Lee, Abraham P.; Northrup, M. Allen; Ciarlo, Dino R.; Krulevitch, Peter A.; Benett, William J.
1999-01-01
Microfabricated therapeutic actuators are fabricated using a shape memory polymer (SMP), a polyurethane-based material that undergoes a phase transformation at a specified temperature (Tg). At a temperature above temperature Tg material is soft and can be easily reshaped into another configuration. As the temperature is lowered below temperature Tg the new shape is fixed and locked in as long as the material stays below temperature Tg. Upon reheating the material to a temperature above Tg, the material will return to its original shape. By the use of such SMP material, SMP microtubing can be used as a release actuator for the delivery of embolic coils through catheters into aneurysms, for example. The microtubing can be manufactured in various sizes and the phase change temperature Tg is determinate for an intended temperature target and intended use.
Microfabricated therapeutic actuators
Lee, A.P.; Northrup, M.A.; Ciarlo, D.R.; Krulevitch, P.A.; Benett, W.J.
1999-06-15
Microfabricated therapeutic actuators are fabricated using a shape memory polymer (SMP), a polyurethane-based material that undergoes a phase transformation at a specified temperature (Tg). At a temperature above temperature Tg material is soft and can be easily reshaped into another configuration. As the temperature is lowered below temperature Tg the new shape is fixed and locked in as long as the material stays below temperature Tg. Upon reheating the material to a temperature above Tg, the material will return to its original shape. By the use of such SMP material, SMP microtubing can be used as a release actuator for the delivery of embolic coils through catheters into aneurysms, for example. The microtubing can be manufactured in various sizes and the phase change temperature Tg is determinate for an intended temperature target and intended use. 8 figs.
Release mechanism utilizing shape memory polymer material
Lee, Abraham P.; Northrup, M. Allen; Ciarlo, Dino R.; Krulevitch, Peter A.; Benett, William J.
2000-01-01
Microfabricated therapeutic actuators are fabricated using a shape memory polymer (SMP), a polyurethane-based material that undergoes a phase transformation at a specified temperature (Tg). At a temperature above temperature Tg material is soft and can be easily reshaped into another configuration. As the temperature is lowered below temperature Tg the new shape is fixed and locked in as long as the material stays below temperature Tg. Upon reheating the material to a temperature above Tg, the material will return to its original shape. By the use of such SMP material, SMP microtubing can be used as a release actuator for the delivery of embolic coils through catheters into aneurysms, for example. The microtubing can be manufactured in various sizes and the phase change temperature Tg is determinate for an intended temperature target and intended use.
A simple laser locking system based on a field-programmable gate array.
Jørgensen, N B; Birkmose, D; Trelborg, K; Wacker, L; Winter, N; Hilliard, A J; Bason, M G; Arlt, J J
2016-07-01
Frequency stabilization of laser light is crucial in both scientific and industrial applications. Technological developments now allow analog laser stabilization systems to be replaced with digital electronics such as field-programmable gate arrays, which have recently been utilized to develop such locking systems. We have developed a frequency stabilization system based on a field-programmable gate array, with emphasis on hardware simplicity, which offers a user-friendly alternative to commercial and previous home-built solutions. Frequency modulation, lock-in detection, and a proportional-integral-derivative controller are programmed on the field-programmable gate array and only minimal additional components are required to frequency stabilize a laser. The locking system is administered from a host-computer which provides comprehensive, long-distance control through a versatile interface. Various measurements were performed to characterize the system. The linewidth of the locked laser was measured to be 0.7 ± 0.1 MHz with a settling time of 10 ms. The system can thus fully match laser systems currently in use for atom trapping and cooling applications.
Labeau, Sonia O; Vandijck, Dominique M; Rello, Jordi; Adam, Sheila; Rosa, Ana; Wenisch, Christoph; Bäckman, Carl; Agbaht, Kemal; Csomos, Akos; Seha, Myriam; Dimopoulos, George; Vandewoude, Koenraad H; Blot, Stijn I
2009-01-01
To determine European intensive care unit (ICU) nurses' knowledge of guidelines for preventing central venous catheter-related infection from the Centers for Disease Control and Prevention. Multicountry survey (October 2006-March 2007). Twenty-two European countries. ICU nurses. Using a validated multiple-choice test, knowledge of ten recommendations for central venous catheter-related infection prevention was evaluated (one point per question) and assessed in relation to participants' gender, ICU experience, number of ICU beds, and acquisition of a specialized ICU qualification. We collected 3405 questionnaires (70.9% response rate); mean test score was 44.4%. Fifty-six percent knew that central venous catheters should be replaced on indication only, and 74% knew this also concerns replacement over a guidewire. Replacing pressure transducers and tubing every 4 days, and using coated devices in patients requiring a central venous catheter >5 days in settings with high infection rates only were recognized as recommended by 53% and 31%, respectively. Central venous catheters dressings in general are known to be changed on indication and at least once weekly by 43%, and 26% recognized that both polyurethane and gauze dressings are recommended. Only 14% checked 2% aqueous chlorhexidine as the recommended disinfection solution; 30% knew antibiotic ointments are not recommended because they trigger resistance. Replacing administration sets within 24 hrs after administering lipid emulsions was recognized as recommended by 90%, but only 26% knew sets should be replaced every 96 hrs when administering neither lipid emulsions nor blood products. Professional seniority and number of ICU beds showed to be independently associated with better test scores. Opportunities exist to optimize knowledge of central venous catheter-related infection prevention among European ICU nurses. We recommend including central venous catheter-related infection prevention guidelines in educational curricula and continuing refresher education programs.
Intravenous catheter training system: computer-based education versus traditional learning methods.
Engum, Scott A; Jeffries, Pamela; Fisher, Lisa
2003-07-01
Virtual reality simulators allow trainees to practice techniques without consequences, reduce potential risk associated with training, minimize animal use, and help to develop standards and optimize procedures. Current intravenous (IV) catheter placement training methods utilize plastic arms, however, the lack of variability can diminish the educational stimulus for the student. This study compares the effectiveness of an interactive, multimedia, virtual reality computer IV catheter simulator with a traditional laboratory experience of teaching IV venipuncture skills to both nursing and medical students. A randomized, pretest-posttest experimental design was employed. A total of 163 participants, 70 baccalaureate nursing students and 93 third-year medical students beginning their fundamental skills training were recruited. The students ranged in age from 20 to 55 years (mean 25). Fifty-eight percent were female and 68% percent perceived themselves as having average computer skills (25% declaring excellence). The methods of IV catheter education compared included a traditional method of instruction involving a scripted self-study module which involved a 10-minute videotape, instructor demonstration, and hands-on-experience using plastic mannequin arms. The second method involved an interactive multimedia, commercially made computer catheter simulator program utilizing virtual reality (CathSim). The pretest scores were similar between the computer and the traditional laboratory group. There was a significant improvement in cognitive gains, student satisfaction, and documentation of the procedure with the traditional laboratory group compared with the computer catheter simulator group. Both groups were similar in their ability to demonstrate the skill correctly. CONCLUSIONS; This evaluation and assessment was an initial effort to assess new teaching methodologies related to intravenous catheter placement and their effects on student learning outcomes and behaviors. Technology alone is not a solution for stand alone IV catheter placement education. A traditional learning method was preferred by students. The combination of these two methods of education may further enhance the trainee's satisfaction and skill acquisition level.
Policies for replacing long-term indwelling urinary catheters in adults.
Cooper, Fergus P M; Alexander, Cameron Edwin; Sinha, Sanjay; Omar, Muhammad Imran
2016-07-26
Long-term indwelling catheters are used commonly in people with lower urinary tract problems in home, hospital and specialised health-care settings. There are many potential complications and adverse effects associated with long-term catheter use. The effect of health-care policies related to the replacement of long-term urinary catheters on patient outcomes is unclear. To determine the effectiveness of different policies for replacing long-term indwelling urinary catheters in adults. We searched the Cochrane Incontinence Specialised Trials Register, which contains trials identified from the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, MEDLINE In-Process, MEDLINE Epub Ahead of Print, CINAHL, ClinicalTrials.gov, WHO ICTRP and handsearching of journals and conference proceedings (searched 19 May 2016), and the reference lists of relevant articles. All randomised controlled trials investigating policies for replacing long-term indwelling urinary catheters in adults were included. At least two review authors independently performed data extraction and assessed risk of bias of all the included trials. Quality of evidence was assessed by adopting the GRADE approach. Any discrepancies were resolved by discussion between the review authors or an independent arbitrator. We contacted the authors of included trials to seek clarification where required. Three trials met the inclusion criteria, with a total of 107 participants in three different health-care settings: A USA veterans administration nursing home; a geriatric centre in Israel; and a community nursing service in Hong Kong. Data were available for three of the pre-stated comparisons. Priefer and colleagues evaluated different time intervals between catheter replacement (n = 17); Firestein and colleagues evaluated the use of antibiotic prophylaxis at the time of replacement (n = 70); and Cheung and colleagues compared two different types of cleaning solutions (n = 20).All the included trials were small and under-powered. The reporting of the trials was inadequate and as a result, risk of bias assessment was judged to be unclear for the majority of the domains in two out of the three trials. There was insufficient evidence to indicate that (i) there was a lower incidence of symptomatic UTI in people whose catheter was changed both monthly and when clinically indicated (risk ratio (RR) 0.35, 95% confidence interval (CI) 0.13 to 0.95; very low quality evidence) compared to only when clinically indicated, (ii) there was not enough evidence to assess the effect of antibiotic prophylaxis on reducing: positive urine cultures at 7 days (RR 0.91, 95% CI 0.79 to 1.04); infection (RR 1.41, 95% CI 0.55 to 3.65); or death (RR 2.12, 95% CI 0.20 to 22.30; very low quality evidence), (iii) there was no statistically significant difference in the incidence of asymptomatic bacteruria at 7 days (RR 0.80, 95% CI 0.42 to 1.52) between people receiving water or chlorhexidine solution for periurethral cleansing at the time of catheter replacement. However, none of the 16 participants developed a symptomatic catheter-associated urinary tract infection (CAUTI) at day 14.The following outcomes were considered critical for decision-making and were also selected for the 'Summary of findings' table: (i) participant satisfaction, (ii) condition-specific quality of life, (iii) urinary tract trauma, and (iv) formal economic analysis. However, none of the trials reported these outcomes.None of the trials compared the following comparisons: (i) replacing catheter versus other policy e.g. washouts, (ii) replacing in the home environment versus clinical environment, (iii) clean versus aseptic technique for replacing catheter, (iv) lubricant A versus lubricant B or no lubricant, and (v) catheter user versus carer versus health professional performing the catheter replacement procedure. There is currently insufficient evidence to assess the value of different policies for replacing long-term urinary catheters on patient outcomes. In particular, there are a number of policies for which there are currently no trial data; and a number of important outcomes which have not been assessed, including patient satisfaction, quality of life, urinary tract trauma, and economic outcomes. There is an immediate need for rigorous, adequately powered randomised controlled trials which assess important clinical outcomes and abide by the principles and recommendations of the CONSORT statement.
Frequency stabilization for multilocation optical FDM networks
NASA Astrophysics Data System (ADS)
Jiang, Quan; Kavehrad, Mohsen
1993-04-01
In a multi-location optical FDM network, the frequency of each user's transmitter can be offset-locked, through a Fabry-Perot, to an absolute frequency standard which is distributed to the users. To lock the local Fabry-Perot to the frequency standard, the standard has to be frequency-dithered by a sinusoidal signal and the sinusoidal reference has to be transmitted to the user location since the lock-in amplifier in the stabilization system requires the reference for synchronous detection. We proposed two solutions to avoid transmitting the reference. One uses an extraction circuit to obtain the sinusoidal signal from the incoming signal. A nonlinear circuit following the photodiode produces a strong second-order harmonic of the sinusoidal signal and a phase-locked loop is locked to it. The sinusoidal reference is obtained by a divide- by-2 circuit. The phase ambiguity (0 degree(s) or 180 degree(s)) is resolved by using a selection- circuit and an initial scan. The other method uses a pseudo-random sequence instead of a sinusoidal signal to dither the frequency standard and a surface-acoustic-wave (SAW) matched-filter instead of a lock-in amplifier to obtain the frequency error. The matched-filter serves as a correlator and does not require the dither reference.
NASA Astrophysics Data System (ADS)
Kim, Dae-Hyeong; Lu, Nanshu; Ghaffari, Roozbeh; Kim, Yun-Soung; Lee, Stephen P.; Xu, Lizhi; Wu, Jian; Kim, Rak-Hwan; Song, Jizhou; Liu, Zhuangjian; Viventi, Jonathan; de Graff, Bassel; Elolampi, Brian; Mansour, Moussa; Slepian, Marvin J.; Hwang, Sukwon; Moss, Joshua D.; Won, Sang-Min; Huang, Younggang; Litt, Brian; Rogers, John A.
2011-04-01
Developing advanced surgical tools for minimally invasive procedures represents an activity of central importance to improving human health. A key challenge is in establishing biocompatible interfaces between the classes of semiconductor device and sensor technologies that might be most useful in this context and the soft, curvilinear surfaces of the body. This paper describes a solution based on materials that integrate directly with the thin elastic membranes of otherwise conventional balloon catheters, to provide diverse, multimodal functionality suitable for clinical use. As examples, we present sensors for measuring temperature, flow, tactile, optical and electrophysiological data, together with radiofrequency electrodes for controlled, local ablation of tissue. Use of such ‘instrumented’ balloon catheters in live animal models illustrates their operation, as well as their specific utility in cardiac ablation therapy. The same concepts can be applied to other substrates of interest, such as surgical gloves.
Reissner-Mindlin Legendre Spectral Finite Elements with Mixed Reduced Quadrature
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brito, K. D.; Sprague, M. A.
2012-10-01
Legendre spectral finite elements (LSFEs) are examined through numerical experiments for static and dynamic Reissner-Mindlin plate bending and a mixed-quadrature scheme is proposed. LSFEs are high-order Lagrangian-interpolant finite elements with nodes located at the Gauss-Lobatto-Legendre quadrature points. Solutions on unstructured meshes are examined in terms of accuracy as a function of the number of model nodes and total operations. While nodal-quadrature LSFEs have been shown elsewhere to be free of shear locking on structured grids, locking is demonstrated here on unstructured grids. LSFEs with mixed quadrature are, however, locking free and are significantly more accurate than low-order finite-elements for amore » given model size or total computation time.« less
Class-A mode-locked lasers: Fundamental solutions
NASA Astrophysics Data System (ADS)
Kovalev, Anton V.; Viktorov, Evgeny A.
2017-11-01
We consider a delay differential equation (DDE) model for mode-locked operation in class-A semiconductor lasers containing both gain and absorber sections. The material processes are adiabatically eliminated as these are considered fast in comparison to the delay time for a long cavity device. We determine the steady states and analyze their bifurcations using DDE-BIFTOOL [Engelborghs et al., ACM Trans. Math. Software 28, 1 (2002)]. Multiple forms of coexistence, transformation, and hysteretic behavior of stable steady states and fundamental periodic regimes are discussed in bifurcation diagrams.
Lebeaux, David; Leflon-Guibout, Véronique; Ghigo, Jean-Marc; Beloin, Christophe
2015-01-01
Treatment of catheter-related bloodstream infections (CRBSI) is hampered by the characteristic tolerance of bacterial biofilms towards antibiotics. Our objective was to study the effect of the combination of antibiotics and the alkaline amino acid l-arginine or the cation chelator EDTA on the bacterial killing of in vitro biofilms formed by an array of clinical strains responsible for CRBSI and representative of epidemiologically relevant bacterial species. Among 32 strains described in a previous clinical study, we focused on the most antibiotic-tolerant strains including CoNS (n = 4), Staphylococcus aureus (n = 4), Enterococcus faecalis (n = 2), Pseudomonas aeruginosa (n = 4) and Enterobacteriaceae (n = 4). We used an in vitro biofilm model (96-well plate assay) to study biofilm tolerance and tested various combinations of antibiotics and non-antibiotic adjuvants. Gentamicin, amikacin or vancomycin was combined with disodium EDTA or l-arginine for 24 h to reproduce the antibiotic lock therapy (ALT) approach. Killing of biofilm bacteria was measured by cfu quantification after a vigorous step of pipetting up and down in order to detach all biofilm bacteria from the surface of the wells. Both of our adjuvant strategies significantly increased the effect of antibiotics against biofilms formed by Gram-positive and Gram-negative bacterial pathogens. The combination of gentamicin + EDTA was active against all tested strains apart from one P. aeruginosa. The combination of gentamicin + l-arginine was active against most of the tested strains with the notable exception of CoNS for which no potentiation was observed. We also demonstrated that amikacin + EDTA was active against Gram-negative bacteria and that vancomycin + EDTA was active against Gram-positive bacteria. The addition of EDTA enhanced the activity of gentamicin, amikacin and vancomycin against biofilms formed by a wide spectrum of bacterial strains responsible for CRBSI. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Stapf, Daniel; Franke, Andreas; Schreckenberg, Marcus; Schummers, Georg; Mischke, Karl; Marx, Nikolaus; Schauerte, Patrick; Knackstedt, Christian
2013-04-01
Three-dimensional (3D)-imaging provides important information on cardiac anatomy during electrophysiological procedures. Real-time updates of modalities with high soft-tissue contrast are particularly advantageous during cardiac procedures. Therefore, a beat to beat 3D visualization of cardiac anatomy by intracardiac echocardiography (ICE) was developed and tested in phantoms and animals. An electronic phased-array 5-10 MHz ICE-catheter (Acuson, AcuNav/Siemens Medical Solutions USA/64 elements) providing a 90° sector image was used for ICE-imaging. A custom-made mechanical prototype controlled by a servo motor allowed automatic rotation of the ICE-catheter around its longitudinal axis. During a single heartbeat, the ICE-catheter was rotated and 2D-images were acquired. Reconstruction into a 3D volume and rendering by a prototype software was performed beat to beat. After experimental validation using a rigid phantom, the system was tested in an animal study and afterwards, for quantitative validation, in a dynamic phantom. Acquisition of beat to beat 3D-reconstruction was technically feasible. However, twisting of the ICE-catheter shaft due to friction and torsion was found and rotation was hampered. Also, depiction of catheters was not always ensured in case of parallel alignment. Using a curved sheath for depiction of cardiac anatomy there was no congruent depiction of shape and dimension of static and moving objects. Beat to beat 3D-ICE-imaging is feasible. However, shape and dimension of static and moving objects cannot always be displayed with necessary steadiness as needed in the clinical setting. As catheter depiction is also limited, clinical use seems impossible.
Gnass, Silvia Acosta; Barboza, Luisa; Bilicich, Dafne; Angeloro, Pablo; Treiyer, Walter; Grenóvero, Silvia; Basualdo, Juan
2004-08-01
To evaluate the incidence of nosocomial bacteremias related to the use of non-impregnated central venous catheters (CVCs) when only non-technologic strategies were used to prevent them. This was a prospective study of infectious complications of CVCs placed in intensive care unit (ICU) patients from April 1997 to December 2001. The medical-surgical ICU of a tertiary-care, university-affiliated hospital in Argentina. We studied all patients admitted to the ICU using non-impregnated CVCs. Maximal sterile barrier precautions (ie, use of cap, mask, sterile gown, sterile gloves, and large sterile drape), strict handwashing, preparation of the patients' skin with antiseptic solutions, insertion and management of catheters by trained personnel, and continuing quality improvement programs aimed at appropriate insertion and maintenance of catheters were employed. During the study period, 2,525 patients were admitted to the ICU. Eight hundred sixty-eight patients had 1,037 CVCs inserted. The number of CVC-related bloodstream infections (BSIs), acquired in the ICU, was 2.7 per 1,000 CVC-days (13 nosocomial CVC-related BSIs during 4,770 days of CVC use). Microorganisms isolated included methicillin-susceptible Staphylococcus aureus (n = 6), methicillin-resistant S. aureus (n = 2), coagulase-negative methicillin-resistant Staphylococcus (n = 2), Escherichia coli (n = 1), Klebsiella pneumoniae (n = 1), and Enterobacter cloacae (n = 1). A low rate of catheter-related BSI was achieved without antimicrobial-impregnated catheters. The incidence of CVC-associated bacteremias corresponded to the 10th to 20th percentile range of the National Nosocomial Infections Surveillance System hospitals for the same type of ICU.
Parity bifurcations in trapped multistable phase locked exciton-polariton condensates
NASA Astrophysics Data System (ADS)
Tan, E. Z.; Sigurdsson, H.; Liew, T. C. H.
2018-02-01
We present a theoretical scheme for multistability in planar microcavity exciton-polariton condensates under nonresonant driving. Using an excitation profile resulting in a spatially patterned condensate, we observe organized phase locking which can abruptly reorganize as a result of pump induced instability made possible by nonlinear interactions. For π /2 symmetric systems this reorganization can be regarded as a parity transition and is found to be a fingerprint of multistable regimes existing over a finite range of excitation strengths. The natural degeneracy of the planar equations of motion gives rise to parity bifurcation points where the condensate, as a function of excitation intensity, bifurcates into one of two anisotropic degenerate solutions. Deterministic transitions between multistable states are made possible using controlled nonresonant pulses, perturbing the solution from one attractor to another.
Spin-lock imaging of exogenous exchange-based contrast agents to assess tissue pH.
Zu, Zhongliang; Li, Hua; Jiang, Xiaoyu; Gore, John C
2018-01-01
Some X-ray contrast agents contain exchangeable protons that give rise to exchange-based effects on MRI, including chemical exchange saturation transfer (CEST). However, CEST has poor specificity to explicit exchange parameters. Spin-lock sequences at high field are also sensitive to chemical exchange. Here, we evaluate whether spin-locking techniques can detect the contrast agent iohexol in vivo after intravenous administration, and their potential for measuring changes in tissue pH. Two metrics of contrast based on R 1ρ , the spin lattice relaxation rate in the rotating frame, were derived from the behavior of R 1ρ at different locking fields. Solutions containing iohexol at different concentrations and pH were used to evaluate the ability of the two metrics to quantify exchange effects. Images were also acquired from rat brains bearing tumors before and after intravenous injections of iohexol to evaluate the potential of spin-lock techniques for detecting the agent and pH variations. The two metrics were found to depend separately on either agent concentration or pH. Spin-lock imaging may therefore provide specific quantification of iohexol concentration and the iohexol-water exchange rate, which reports on pH. Spin-lock techniques may be used to assess the dynamics of intravenous contrast agents and detect extracellular acidification. Magn Reson Med 79:298-305, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Closed-chest cardiopulmonary bypass and cardioplegia: basis for less invasive cardiac surgery.
Peters, W S; Siegel, L C; Stevens, J H; St Goar, F G; Pompili, M F; Burdon, T A
1997-06-01
We developed a method of closed-chest cardiopulmonary bypass to arrest and protect the heart with cardioplegic solution. This method was used in 54 dogs and the results were retrospectively analyzed. Bypass cannulas were placed in the right femoral vessels. A balloon occlusion catheter was passed via the left femoral artery and positioned in the ascending aorta. A pulmonary artery vent was placed via the jugular vein. In 17 of the dogs retrograde cardioplegia was provided with a percutaneous coronary sinus catheter. Cardiopulmonary bypass time was 111 +/- 27 minutes (mean +/- standard deviation) and cardiac arrest time was 66 +/- 21 minutes. Preoperative cardiac outputs were 2.9 +/- 0.70 L/min and postoperative outputs were 2.9 +/- 0.65 L/min (p = not significant). Twenty-one-French and 23F femoral arterial cannulas that allowed coaxial placement of the ascending aortic balloon catheter were tested in 3 male calves. Line pressures were higher, but not clinically limiting, with the balloon catheter placed coaxially. Adequate cardiopulmonary bypass and cardioplegia can be achieved in the dog without opening the chest, facilitating less invasive cardiac operations. A human clinical trial is in progress.
Enhanced central venous catheter bundle for pediatric parenteral-dependent intestinal failure.
Ormsby, Jennifer A; Bukoye, Bola; Lajoie, Debra; Shermont, Herminia; Martin, Lisa; Leger, Kierrah; Mahoney, Judy; Potter-Bynoe, Gail; Carpenter, Jane; Ozonoff, Al; Lee, Grace M
2018-05-16
Central line-associated bloodstream infections (CLABSIs) cause substantial morbidity and increase antimicrobial use and length of stay among hospitalized children in the United States. CLABSI occurs more frequently among high-risk pediatric patients, such as those with intestinal failure (IF) who are parenteral nutrition (PN) dependent. Following an increase in CLABSI rates, a quality improvement (QI) initiative was implemented. Using QI methodology, an enhanced central venous catheter (CVC) maintenance bundle was developed and implemented on 2 units for pediatric PN-dependent patients with IF. CLABSI rates were prospectively monitored pre- and postimplementation, and bundle element adherence was monitored. Enhanced bundle elements included chlorhexidine-impregnated patch, daily bathing, ethanol locks, 2 nurses for CVC care in a distraction-free zone, peripheral laboratory draws, bundling routine laboratory tests, and PN administration set changes every 24 hours. Adherence to enhanced bundle elements increased to >90% over 3 months. CLABSI rates averaged 1.41 per 1,000 central line days preimplementation compared with 0.40 per 1,000 device days postimplementation (P = .003), an 85% absolute reduction in CLABSI rates over 12 months. Patients with IF are at an increased risk for CLABSI. Enhanced CVC maintenance bundles that specifically target prevention practices in this population may be beneficial. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Izzo, Ilaria; Lania, Donatella; Castro, Antonino; Lanzini, Fernanda; Bella, Daniele; Pagani, Adriano; Colombini, Paolo
2014-06-01
Pantoea agglomerans, a gram negative bacillus in the Enterobacteriaceae family, has been isolated from feculent material, plants and soil. Soft tissue and bone-joint infections due to P. agglomerans following penetrating trauma by vegetation and bacteraemia in association with intravenous fluid, total parenteral nutrition, blood products and anaesthetic agent contamination have been reported. Between October 2009 and January 2010 seven cases of port a cath contamination caused by P. agglomerans were observed in the Oncological Service of our hospital. All patients presented with septic fever after heparinization of the central venous catheter. 5/7 patients were female; mean age was 67 years (range 58-75). 6/7 patients were affected by colorectal adenocarcinoma, 1/7 by mammarian cancer. Mean time from CVC insertion was 23.8 months (range 13-42) at the time of fever. In three cases, port a cath was removed following the oncologist prescription. P. agglomerans was isolated from the catheter tip in one case and from CVC blood culture in 6-7 cases. In all cases peripheral blood cultures were negative. Patients were treated with ciprofloxacin lock therapy and systemic therapy (per os), obtaining negative cultures from port a cath. Notwithstanding the absence of isolation of Pantoea strains from environmental cultures, after educational intervention, which underlined some faulty procedures in CVC management, no further cases were observed.
Phase-locking and bistability in neuronal networks with synaptic depression
NASA Astrophysics Data System (ADS)
Akcay, Zeynep; Huang, Xinxian; Nadim, Farzan; Bose, Amitabha
2018-02-01
We consider a recurrent network of two oscillatory neurons that are coupled with inhibitory synapses. We use the phase response curves of the neurons and the properties of short-term synaptic depression to define Poincaré maps for the activity of the network. The fixed points of these maps correspond to phase-locked modes of the network. Using these maps, we analyze the conditions that allow short-term synaptic depression to lead to the existence of bistable phase-locked, periodic solutions. We show that bistability arises when either the phase response curve of the neuron or the short-term depression profile changes steeply enough. The results apply to any Type I oscillator and we illustrate our findings using the Quadratic Integrate-and-Fire and Morris-Lecar neuron models.
Fürst, Rafael Vilhena de Carvalho; Polimanti, Afonso César; Galego, Sidnei José; Bicudo, Maria Claudia; Montagna, Erik; Corrêa, João Antônio
2017-03-01
To present a simple and affordable model able to properly simulate an ultrasound-guided venous access. The simulation was made using a latex balloon tube filled with water and dye solution implanted in a thawed chicken breast with bones. The presented model allows the simulation of all implant stages of a central catheter. The obtained echogenicity is similar to that observed in human tissue, and the ultrasound identification of the tissues, balloon, needle, wire guide and catheter is feasible and reproducible. The proposed model is simple, economical, easy to manufacture and capable of realistically and effectively simulating an ultrasound-guided venous access.
Sales, Camila Pessoa; Carvalho, Heloisa de Andrade; Taverna, Khallil Chaim; Pastorello, Bruno Fraccini; Rubo, Rodrigo Augusto; Borgonovi, Arthur Felipe; Stuart, Silvia Radwanski; Rodrigues, Laura Natal
2016-01-01
Objective To identify a contrast material that could be used as a dummy marker for magnetic resonance imaging. Materials and Methods Magnetic resonance images were acquired with six different catheter-filling materials-water, glucose 50%, saline, olive oil, glycerin, and copper sulfate (CuSO4) water solution (2.08 g/L)-inserted into compatible computed tomography/magnetic resonance imaging ring applicators placed in a phantom made of gelatin and CuSO4. The best contrast media were tested in four patients with the applicators in place. Results In T2-weighted sequences, the best contrast was achieved with the CuSO4-filled catheters, followed by saline- and glycerin-filled catheters, which presented poor visualization. In addition (also in T2-weighted sequences), CuSO4 presented better contrast when tested in the phantom than when tested in the patients, in which it provided some contrast but with poor identification of the first dwell position, mainly in the ring. Conclusion We found CuSO4 to be the best solution for visualization of the applicator channels, mainly in T2-weighted images in vitro, although the materials tested presented low signal intensity in the images obtained in vivo, as well as poor precision in determining the first dwell position. PMID:27403016
Peshikov, V L; Tsirkin, V I; Burmistrova, T D; Bordunovskaia, V P
1977-09-01
Contractile effects of adrenaline, acethylcholine and hyperpotassium solution on the isolated myometrium strips (non-pregnent rats, and women; pregnant rabbits, cats, and women) are studied. The amplitudes of these contractile effects were seen decreasing if the strips were previously immersed in the Ringer-Lokk solution at 4 degrees C 5--9 days prior to observation.
Zhang, James J; Hogstrom, Barry; Malinak, Jiri; Ikei, Nobuhiro
2016-05-01
It can be challenging to achieve adequate vessel opacification during percutaneous coronary interventions when using thin catheters, hand injection, and iso-osmolar contrast media (CM) such as iodixanol (Visipaque™). To explore these limitations and the possibility to overcome them with iosimenol, a novel CM. Three X-ray contrast media with different concentrations were used in this study. A series of in vitro experiments established the relationship between injection pressure and flow rate in angiography catheters under various conditions. The experiments were conducted with power and hand injections and included a double-blind evaluation of user perception. By using hand injection, it was generally not possible to reach a maximum injection pressure exceeding 50 psi. The time within which volunteers were able to complete the injections, the area under the pressure-time curve (AUC), and assessment of ease of injection all were in favor of iosimenol compared with iodixanol, especially when using the 4F thin catheter. Within the pressure ranges tested, the power injections demonstrated that the amount of iodine delivered at a fixed pressure was strongly related to viscosity but unrelated to iodine concentration. There are substantial limitations to the amount of iodine that can be delivered through thin catheters by hand injection when iso-osmolar CM with high viscosity is used. The only viable solution, besides increasing the injection pressure, is to use a CM with lower viscosity, since the cost of increasing the concentration, in terms of increased viscosity and consequent reduction in flow, is too high. Iosimenol, an iso-osmolar CM with lower viscosity than iodixanol might therefore be a better alternative when thinner catheters are preferred, especially when the radial artery is used as the access site. © The Foundation Acta Radiologica 2015.
Home parenteral nutrition in children: the Polish experience.
Ksiazyk, J; Lyszkowska, M; Kierkus, J; Bogucki, K; Ratyńska, A; Tondys, B; Socha, J
1999-02-01
Home parenteral nutrition has become routine for management of intestinal failure in patients. In Poland the main obstacle to widespread use of home parenteral nutrition is the lack of interest of commercial companies in delivering feedings and ancillaries to patients. Twenty-five home parenteral nutrition patients aged from 4 months to more than 13 years were reviewed. The mother or both parents were trained in home parenteral nutrition techniques for 4 to 6 weeks and compounded the nutrients themselves at home. The mean duration of home parenteral nutrition was 10,117 patient days. Hospital stays of patients receiving parenteral feedings were significantly shorter than the duration of administration of home parenteral nutrition (p < 0.001). Eleven children are continuing the home parenteral nutrition program. Eighty-three catheters were used in these patients. The rate of catheter occlusion decreased within the observation period, and in 1997 not one case of occlusion was observed. In 1997 only three catheters were removed during 7.8 patient years, and the overall incidence of catheter-related complications was 0.38 per patient year. The overall occurrence of septicemia was one case in 516 days and of catheter infection was one in 459 days. In 1997 a catheter was infected on average of once every 1419 days. There was significant improvement in the z score for weight during therapy. The average monthly cost of nutrients and ancillary items was approximately $1200 (4200 Polish zlotys [PLN]). These costs are 1.6 to 3 times lower than those recorded in other studies. Home parenteral nutrition in children with nutrients mixed by caregivers in the home setting is a safe and appropriate method of treatment that can be used in countries where home parenteral nutrition solutions are not manufactured or where commercial home parenteral nutrition is not economically feasible.
Guo, Liang; Monahan, Daniele M; Fleming, Graham
2016-08-08
Spectrometers and cameras are used in ultrafast spectroscopy to achieve high resolution in both time and frequency domains. Frequency-resolved signals from the camera pixels cannot be processed by common lock-in amplifiers, which have only a limited number of input channels. Here we demonstrate a rapid and economical method that achieves the function of a lock-in amplifier using mechanical choppers and a programmable microcontroller. We demonstrate the method's effectiveness by performing a frequency-resolved pump-probe measurement on the dye Nile Blue in solution.
2012-01-10
flow cytometry, locked nucleic acid, sRNA, Vibrio , Date Published: 1/10/2012 This is an open-access article distributed under the terms of the Creative...solubilization process to maintain a 10 mL volume. Aliquot the 60% dextran sulfate solution and store at -20 °C until use. 1. Harvest 1x108 cells of...bioluminescent Vibrio campbellii or your bacteria of interest and transfer them into a 1.5 mL microcentrifuge tube. This quantity of cells provides
Anticipated and zero-lag synchronization in motifs of delay-coupled systems
NASA Astrophysics Data System (ADS)
Mirasso, Claudio R.; Carelli, Pedro V.; Pereira, Tiago; Matias, Fernanda S.; Copelli, Mauro
2017-11-01
Anticipated and zero-lag synchronization have been observed in different scientific fields. In the brain, they might play a fundamental role in information processing, temporal coding and spatial attention. Recent numerical work on anticipated and zero-lag synchronization studied the role of delays. However, an analytical understanding of the conditions for these phenomena remains elusive. In this paper, we study both phenomena in systems with small delays. By performing a phase reduction and studying phase locked solutions, we uncover the functional relation between the delay, excitation and inhibition for the onset of anticipated synchronization in a sender-receiver-interneuron motif. In the case of zero-lag synchronization in a chain motif, we determine the stability conditions. These analytical solutions provide an excellent prediction of the phase-locked regimes of Hodgkin-Huxley models and Roessler oscillators.
Yeste Sánchez, Luis; Galbis Caravajal, José M; Fuster Diana, Carlos A; Moledo Eiras, Enrique
2006-10-01
The cannulation of suitable peripheral veins may be a very painful experience. Implantable venous access systems have to some degree relieved this problem and help to provide an improvement in terms of quality of life. We have evaluated 560 patients during a follow up period of two years. A low overall complication percentage of 7.32% was seen when using the venous access device. Complications and treatments were: pneumothorax; portal rotation or infection; catheter infection; embolism and migration; extravasation; partial or total obstruction of the device; rupture of the catheter or the membrane. There is no other system that allows repeated venous access on such a long term basis. Placing the devices completely under the skin allows the patient to conduct a normal life style, and its maintenance does not need any special care, with the exception of the monthly heparinised serum infusion. The preferred option is to insert the catheter through the cephalic vein in the delto pectoral groove.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheth, Rahul; Someshwar, Vimal; Warawdekar, Gireesh
2007-02-15
Purpose. We report our experience of the retrieval of intravascular foreign body objects by the percutaneous use of the Gemini Dormia basket. Methods. Over a period of 2 years we attempted the percutaneous removal of intravascular foreign bodies in 26 patients. Twenty-six foreign bodies were removed: 8 intravascular stents, 4 embolization coils, 9 guidewires, 1 pacemaker lead, and 4 catheter fragments. The percutaneous retrieval was achieved with a combination of guide catheters and the Gemini Dormia basket. Results. Percutaneous retrieval was successful in 25 of 26 patients (96.2%). It was possible to remove all the intravascular foreign bodies with amore » combination of guide catheters and the Dormia basket. No complication occurred during the procedure, and no long-term complications were registered during the follow-up period, which ranged from 6 months to 32 months (mean 22.4 months overall). Conclusion. Percutaneous retrieval is an effective and safe technique that should be the first choice for removal of an intravascular foreign body.« less
Cook, David J; Thompson, Jeffrey E; Suri, Rakesh; Prinsen, Sharon K
2014-01-01
The absence of standardization in surgical care process, exemplified in a "solution shop" model, can lead to unwarranted variation, increased cost, and reduced quality. A comprehensive effort was undertaken to improve quality of care around indwelling bladder catheter use following surgery by creating a "focused factory" model within the cardiac surgical practice. Baseline compliance with Surgical Care Improvement Inf-9, removal of urinary catheter by the end of surgical postoperative day 2, was determined. Comparison of baseline data to postintervention results showed clinically important reductions in the duration of indwelling bladder catheters as well as marked reduction in practice variation. Following the intervention, Surgical Care Improvement Inf-9 guidelines were met in 97% of patients. Although clinical quality improvement was notable, the process to accomplish this-identification of patients suitable for standardized pathways, protocol application, and electronic systems to support the standardized practice model-has potentially greater relevance than the specific clinical results. © 2013 by the American College of Medical Quality.
Intramuscular Contact Lead Filled With Conductive Solution
NASA Technical Reports Server (NTRS)
Bamford, Robert M.; Hendrickson, James A.
1991-01-01
Proposed sheath for braided-wire intramuscular conductor preserves electrical continuity even if wire breaks. Plastic sheath surrounds conductive solution in which braided wire immersed. At end of cable, wire and sheath crimped together and press-fit in porous titanium electrode. Implanted surgically with aid of device resembling catheter. Used to deliver electrical stimuli to muscles in biomedical research on human and animal physiology, development of prostheses, regeneration of nerves and muscles, and artificial implants.
Infiltration and extravasation.
Hadaway, Lynn
2007-08-01
The Infusion Nurses Society's national standards of practice require that a nurse who administers IV medication or fluid know its adverse effects and appropriate interventions to take before starting the infusion. A serious complication is the inadvertent administration of a solution or medication into the tissue surrounding the IV catheter--when it is a nonvesicant solution or medication, it is called infiltration; when it is a vesicant medication, it is called extravasation. Both infiltration and extravasation can have serious consequences: the patient may need surgical intervention resulting in large scars, experience limitation of function, or even require amputation. Another long-term effect is complex regional pain syndrome, a neurologic syndrome that requires long-term pain management. These outcomes can be prevented by using appropriate nursing interventions during IV catheter insertion and early recognition and intervention upon the first signs and symptoms of infiltration and extravasation. Nursing interventions include early recognition, prevention, and treatment (including the controversial use of antidotes, and heat and cold therapy). Steps to manage infiltration and extravasation are presented.
Effects of Equilibrium Toroidal Flow on Locked Mode and Plasma Response in a Tokamak
NASA Astrophysics Data System (ADS)
Zhu, Ping; Huang, Wenlong; Yan, Xingting
2016-10-01
It is widely believed that plasma flow plays significant roles in regulating the processes of mode locking and plasma response in a tokamak in presence of external resonant magnetic perturbations (RMPs). Recently a common analytic relation for both locked mode and plasma response has been developed based on the steady-state solution to the coupled dynamic system of magnetic island evolution and torque balance. The analytic relation predicts the size of the magnetic island of a locked mode or a static nonlinear plasma response for a given RMP amplitude, and rigorously proves a screening effect of the equilibrium toroidal flow. To test the theory, we solve for the locked mode and the nonlinear plasma response in presence of RMP for a circular-shaped limiter tokamak equilibrium with constant toroidal flow, using the initial-value, full MHD simulation code NIMROD. The comparison between the simulation results and the theory prediction, in terms of the quantitative screening effects of equilibrium toroidal flow, will be reported and discussed. Supported by National Magnetic Confinement Fusion Science Program of China Grants 2014GB124002 and 2015GB101004, the 100 Talent Program of the Chinese Academy of Sciences, and U.S. Department of Energy Grants DE-FG02-86ER53218 and DE-FC02-08ER54975.
[Effect of subglottic air insufflation on subglottic pressure during swallowing].
Clarett, M; Andreu, M F; Salvati, I G; Donnianni, M C; Montes, G S; Rodríguez, M G
2014-04-01
To determine whether there are differences between subglottic pressure during swallowing with and without air insufflation via a subglottic catheter in tracheostomized patients. A prospective, randomized cross-over study was made. Adult Intensive Care Units. Patients requiring mechanical ventilation and tracheostomy with a subglottic catheter, and with tolerance to deflation of the balloon and a speaking valve placed over the opening of the tracheostomy tube. Subglottic pressure was measured during swallowing of a thickened solution with and without the delivery of airflow through the subglottic catheter. Subglottic pressure during swallowing. Twelve out of 14 patients showed higher subglottic pressure values during swallowing with air insufflation. Two patients showed no differences between both conditions. Median (Med) values of subglottic pressure for the first, second and third swallow were 5, 4 and 4.5 cmH2O (Med 4.5 cmH2O) without air insufflation, and 8, 5.5 and 7.5 cmH2O (Med 5.5 cmH2O) with air insufflation, respectively (Wilcoxon, Z=-3.078; p=.002). In a group of tracheostomized patients, air insufflation via a subglottic catheter increased subglottic pressure levels measured during swallowing. Copyright © 2012 Elsevier España, S.L. and SEMICYUC. All rights reserved.
A simple laser locking system based on a field-programmable gate array
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jørgensen, N. B.; Birkmose, D.; Trelborg, K.
Frequency stabilization of laser light is crucial in both scientific and industrial applications. Technological developments now allow analog laser stabilization systems to be replaced with digital electronics such as field-programmable gate arrays, which have recently been utilized to develop such locking systems. We have developed a frequency stabilization system based on a field-programmable gate array, with emphasis on hardware simplicity, which offers a user-friendly alternative to commercial and previous home-built solutions. Frequency modulation, lock-in detection, and a proportional-integral-derivative controller are programmed on the field-programmable gate array and only minimal additional components are required to frequency stabilize a laser. The lockingmore » system is administered from a host-computer which provides comprehensive, long-distance control through a versatile interface. Various measurements were performed to characterize the system. The linewidth of the locked laser was measured to be 0.7 ± 0.1 MHz with a settling time of 10 ms. The system can thus fully match laser systems currently in use for atom trapping and cooling applications.« less
NASA Astrophysics Data System (ADS)
Miao, Di; Borden, Michael J.; Scott, Michael A.; Thomas, Derek C.
2018-06-01
In this paper we demonstrate the use of B\\'{e}zier projection to alleviate locking phenomena in structural mechanics applications of isogeometric analysis. Interpreting the well-known $\\bar{B}$ projection in two different ways we develop two formulations for locking problems in beams and nearly incompressible elastic solids. One formulation leads to a sparse symmetric symmetric system and the other leads to a sparse non-symmetric system. To demonstrate the utility of B\\'{e}zier projection for both geometry and material locking phenomena we focus on transverse shear locking in Timoshenko beams and volumetric locking in nearly compressible linear elasticity although the approach can be applied generally to other types of locking phenemona as well. B\\'{e}zier projection is a local projection technique with optimal approximation properties, which in many cases produces solutions that are comparable to global $L^2$ projection. In the context of $\\bar{B}$ methods, the use of B\\'ezier projection produces sparse stiffness matrices with only a slight increase in bandwidth when compared to standard displacement-based methods. Of particular importance is that the approach is applicable to any spline representation that can be written in B\\'ezier form like NURBS, T-splines, LR-splines, etc. We discuss in detail how to integrate this approach into an existing finite element framework with minimal disruption through the use of B\\'ezier extraction operators and a newly introduced dual basis for the B\\'{e}zierprojection operator. We then demonstrate the behavior of the two proposed formulations through several challenging benchmark problems.
Su, Z; Bai, Y H; Hou, X M
2017-02-18
To compare the effect of four different techniques on removal of vapor lock in the apical region of curved root canals. Forty simulated resin root canals with 45° curvature were prepared using WaveOne Primary, then the apical foramen were sealed with soft wax. The teeth were divided randomly into 4 groups thereafter (n=10). Contract solution was injected into the canals using a 30 G side-vented needle and scanned with cone-beam CT (CBCT) to identify the volume of the vapor lock. Four different techniques including photon-induced photoacoustic streaming (PIPS) laser-activated irrigation, gutta-percha cone technique, ultrasonic irrigation, and sonic irrigation were used to remove the vapor locks in the root canals. The residual volume of the vapor lock was identified again using CBCT scanning data. Accordingly, the reduction rates of the vapor lock were calculated. Furthermore, the initial and residual vapor lock length was calculated. The data were analyzed by using the One-way ANOVA analysis and Kruskal-Wallis H test at a significance level of P<0.05. There was no significant difference in the initial vapor lock volume (P>0.05). Residual volume of the vapor lock for PIPS laser-activated irrigation was 0 mm(3), and that for gutta-percha cone technique was (0.02±0.07) mm3, significantly lower than those of ultrasonic and sonic irrigation, the values being (0.20±0.09) mm(3) and (0.23±0.06) mm(3) (P<0.001), respectively. The reduction rates of the vapor lock of PIPS laser-activated irrigation and gutta-percha cone technique were 100.00% (100.00%, 100.00%) and 100.00% (77.66%, 100.00%), respectively, significantly higher than those of ultrasonic irrigation [70.37% (56.41%, 91.43%)] and sonic irrigation [63.54% (51.47%, 74.00%), P<0.001]. The length of the residual vapor lock for PIPS laser-activated irrigation was 0 mm, and that for gutta-percha cone technique was (0.15±0.47) mm, significantly lower than those of ultrasonic and sonic irrigation, values being (2.21±0.09) mm and (2.34±0.08) mm (P<0.001), respectively. The length of the residual vapor locks in the ultrasonic and sonic group remained approximately the same as the distance between the working tip and the apical foramen. PIPS laser activated irrigation and gutta-percha cone technique could remove the vapor lock from the apical region of curved canals effectively.
Mid-IR super-continuum generation
NASA Astrophysics Data System (ADS)
Islam, Mohammed N.; Xia, Chenan; Freeman, Mike J.; Mauricio, Jeremiah; Zakel, Andy; Ke, Kevin; Xu, Zhao; Terry, Fred L., Jr.
2009-02-01
A Mid-InfraRed FIber Laser (MIRFIL) has been developed that generates super-continuum covering the spectral range from 0.8 to 4.5 microns with a time-averaged power as high as 10.5W. The MIRFIL is an all-fiber integrated laser with no moving parts and no mode-locked lasers that uses commercial off-the-shelf parts and leverages the mature telecom/fiber optics platform. The MIRFIL power can be easily scaled by changing the repetition rate and modifying the erbium-doped fiber amplifier. Some of the applications using the super-continuum laser will be described in defense, homeland security and healthcare. For example, the MIRFIL is being applied to a catheter-based medical diagnostic system to detect vulnerable plaque, which is responsible for most heart attacks resulting from hardening-of-the-arteries or atherosclerosis. More generally, the MIRFIL can be a platform for selective ablation of lipids without damaging normal protein or smooth muscle tissue.
NASA Astrophysics Data System (ADS)
Soto-Crespo, J. M.; Akhmediev, Nail
2002-12-01
The complex quintic Swift-Hohenberg equation (CSHE) is a model for describing pulse generation in mode-locked lasers with fast saturable absorbers and a complicated spectral response. Using numerical simulations, we study the single- and two-soliton solutions of the (1+1)-dimensional complex quintic Swift-Hohenberg equations. We have found that several types of stationary and moving composite solitons of this equation are generally stable and have a wider range of existence than for those of the complex quintic Ginzburg-Landau equation. We have also found that the CSHE has a wider variety of localized solutions. In particular, there are three types of stable soliton pairs with π and π/2 phase difference and three different fixed separations between the pulses. Different types of soliton pairs can be generated by changing the parameter corresponding to the nonlinear gain (ɛ).
NASA Astrophysics Data System (ADS)
Broslavets, Y. Y.; Fomitchev, A. A.
1996-11-01
We report on investigation of mode-locked regime in tunable Cr4+:YAG laser. Our experiments have been performed using Nd:YAG laser for pumping Cr4+:Y3Al5O12 laser. We have obtained mode-locked generation of tunable radiation in the range from 1,350 to 1,550 nm. There was a generation with pulse duration in ps range and repetition rate of 320 MHz. Using a 0.5 percent transmitting output mirror, as high as 305 mW of useful output power at 1.5 micrometers was obtained from the laser with 5.5 W of absorbed pump power. The laser has threshold for mode-locked regime near 7 W for synchronous mode locking and 5 W for active mode locking. We have analyzed the laser system with Kerr lens feedback in the phase trajectory of five-dimensional space. The computer simulation have shown the presence of asymptotically stable stationary point in behavior of temporal Gaussian beam similar spatial mode structure in the resonators, when the temporal mode does not change passing through all dispersion element in laser. Our calculations show that the sign of dispersion is very important for formation of phase portrait in our laser system. In conclusion, we have demonstrated Cr4+:YAG laser operation in mode-locked regime on the edge of stability region. The analysis of the solutions in our model reveals that chaotic instabilities can be reached through increasing of non-linear interaction temporal and spatial Gaussian beam. The characteristics of this laser systems can provide the source of laser radiation for diagnostics and therapy.
Charpiat, B; Magdinier, C; Leboucher, G; Aubrun, F
2016-01-01
Accidental direct intravenous injection of a concentrated solution of potassium often leads to patient death. In France, recommendations of healthcare agencies to prevent such accidents cover only preparation and intravenous infusion conditions. Accidents continue to occur in French hospitals. These facts demonstrate that these recommendations are insufficient and ineffective to prevent such deaths, especially those occurring during a catheter flushing. This article reviews the measures able to reduce the number of accidents. Countries which removed concentrated ampoules from ward stocks observed a decrease of the number of accidental deaths. This withdrawal, recommended by the World Health Organization, is now part of standards in studies aimed at determining the safety of care in hospitals. However, removal alone is insufficient to eliminate the risk. The combination with other measures should be considered. These measures are the provision of a combination of diluted intravenous ready to use solutions, the promotion of the oral route with tablets and oral solutions for potassium replenishment and to make available products with safeguards to prevent single shot intravenous injection. Studies aimed at determining the consequences on preventing concentrated potassium accidents of a widespread distribution of isotonic sodium chloride pre-filled ready-to-use syringes for catheter flushing should be performed. Copyright © 2015 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.
Crisis route to chaos in semiconductor lasers subjected to external optical feedback
NASA Astrophysics Data System (ADS)
Wishon, Michael J.; Locquet, Alexandre; Chang, C. Y.; Choi, D.; Citrin, D. S.
2018-03-01
Semiconductor lasers subjected to optical feedback have been intensively used as archetypical testbeds for high-speed (sub-ns) and high-dimensional nonlinear dynamics. By simultaneously extracting all the dynamical variables, we demonstrate that for larger current, the commonly named "quasiperiodic" route is in fact based on mixed external-cavity solutions that lock the oscillation frequency of the intensity, voltage, and separation in optical frequency through a mechanism involving successive rejections along the unstable manifold of an antimode. We show that chaos emerges from a crisis resulting from the inability to maintain locking as the unstable manifold becomes inaccessible.
Determination of lesion size by ultrasound during radiofrequency catheter ablation.
Awad, S; Eick, O
2003-01-01
The catheter tip temperature that is used to control the radiofrequency generator output poorly correlates to lesion size. We, therefore, evaluated lesions created in vitro using a B-mode ultrasound imaging device as a potential means to assess lesion generation during RF applications non-invasively. Porcine ventricular tissue was immersed in saline solution at 37 degrees C. The catheter was fixed in a holder and positioned in a parallel orientation to the tissue with an array transducer (7.5 MHz) app. 3 cm above the tissue. Lesions were produced either in a temperature controlled mode with a 4-mm tip catheter with different target temperatures (50, 60, 70 and 80 degrees C, 80 W maximum output) or in a power controlled mode (25, 50 and 75 W, 20 ml/min irrigation flow) using an irrigated tip catheter. Different contact forces (0.5 N, 1.0 N) were tested, and RF was delivered for 60 s. A total of 138 lesions was produced. Out of these, 128 could be identified on the ultrasound image. The lesion depth and volume was on average 4.1 +/- 1.6 mm and 52 +/- 53 mm3 as determined by ultrasound and 3.9 +/- 1.7 mm and 52 +/- 55 mm3 as measured thereafter, respectively. A linear correlation between the lesion size determined by ultrasound and that measured thereafter was demonstrated with a correlation coefficient of r = 0.87 for lesion depth and r = 0.93 for lesion volume. We conclude that lesions can be assessed by B-mode ultrasound imaging.
1700 nm and 1800 nm band tunable thulium doped mode-locked fiber lasers.
Emami, Siamak Dawazdah; Dashtabi, Mahdi Mozdoor; Lee, Hui Jing; Arabanian, Atoosa Sadat; Rashid, Hairul Azhar Abdul
2017-10-06
This paper presents short wavelength operation of tunable thulium-doped mode-locked lasers with sweep ranges of 1702 to 1764 nm and 1788 to 1831 nm. This operation is realized by a combination of the partial amplified spontaneous emission suppression method, the bidirectional pumping mechanism and the nonlinear polarization rotation (NPR) technique. Lasing at emission bands lower than the 1800 nm wavelength in thulium-doped fiber lasers is achieved using mode confinement loss in a specially designed photonic crystal fiber (PCF). The enlargement of the first outer ring air holes around the core region of the PCF attenuates emissions above the cut-off wavelength and dominates the active region. This amplified spontaneous emission (ASE) suppression using our presented PCF is applied to a mode-locked laser cavity and is demonstrated to be a simple and compact solution to widely tunable all-fiber lasers.
Modeling of mode-locked fiber lasers
NASA Astrophysics Data System (ADS)
Shaulov, Gary
This thesis presents the results of analytical and numerical simulations of mode-locked fiber lasers and their components: multiple quantum well saturable absorbers and nonlinear optical loop mirrors. Due to the growing interest in fiber lasers as a compact source of ultrashort pulses there is a need to develop a full understanding of the advantages and limitations of the different mode-locked techniques. The mode-locked fiber laser study performed in this thesis can be used to optimize the design and performance of mode-locked fiber laser systems. A group at Air Force Research Laboratory reported a fiber laser mode-locked by multiple quantum well (MQW) saturable absorber with stable pulses generated as short as 2 ps [21]. The laser cavity incorporates a chirped fiber Bragg grating as a dispersion element; our analysis showed that the laser operates in the soliton regime. Soliton perturbation theory was applied and conditions for stable pulse operation were investigated. Properties of MQW saturable absorbers and their effect on cavity dynamics were studied and the cases of fast and slow saturable absorbers were considered. Analytical and numerical results are in a good agreement with experimental data. In the case of the laser cavity with a regular fiber Bragg grating, the properties of MQW saturable absorbers dominate the cavity dynamics. It was shown that despite the lack of a soliton shaping mechanism, there is a regime in parameter space where stable or quasi-stable solitary waves solutions can exist. Further a novel technique of fiber laser mode-locking by nonlinear polarization rotation was proposed. Polarization rotation of vector solitons was simulated in a birefringent nonlinear optical loop mirror (NOLM) and the switching characteristics of this device was studied. It was shown that saturable absorber-like action of NOLM allows mode-locked operation of the two fiber laser designs. Laser cavity designs were proposed: figure-eight-type and sigma-type cavity.
Turan, Alparslan; Babazade, Rovnat; Elsharkawy, Hesham; Esa, Wael Ali Sakr; Maheshwari, Kamal; Farag, Ehab; Zimmerman, Nicole M; Soliman, Loran Mounir; Sessler, Daniel I
2017-03-01
Ultrasound-guided nerve blocks have become the standard when performing regional nerve blocks in anaesthesia. Infiniti Plus (CIVCO Medical Solutions, Kalona, Iowa, USA) is a needle guide that has been recently developed to help clinicians in performing ultrasound-guided nerve blocks. We tested the hypothesis that femoral nerve catheter placement carried out with the Infiniti Plus needle guide will be quicker to perform than without the Infiniti Plus. Secondary aims were to assess whether the Infiniti Plus needle guide decreased the number of block attempts and also whether it improved needle visibility. A randomised, controlled trial. Cleveland Clinic, Cleveland, Ohio, USA. We enrolled adult patients having elective total knee arthroplasty with a femoral nerve block and femoral nerve catheter. Patients, who were pregnant or those who had preexisting neuropathy involving the surgical limb, coagulopathy, infection at the block site or allergy to local anaesthetics were excluded. Patients were randomised into two groups to receive the ultrasound-guided femoral nerve catheter placement with or without the Infiniti Plus needle guide. The time taken to place the femoral nerve catheter, the number of attempts, the success rate and needle visibility were recorded. We used an overall α of 0.05 for both the primary and secondary analyses; the secondary analyses were Bonferroni corrected to control for multiple comparisons. The median (interquartile range Q1 to Q3) time to perform the femoral nerve catheter placement was 118 (100 to 150) s with Infiniti Plus and 177 (130 to 236) s without Infiniti Plus. Infiniti Plus significantly reduced the time spent performing femoral nerve catheterisation, with estimated ratio of means [(95% confidence interval), P value] of 0.67 [(0.60 to 0.75), P < 0.001] with Infiniti Plus compared with no Infiniti Plus. However, Infiniti Plus had no effect on the odds of a successful femoral nerve catheter placement, number of attempts or percentage of perfect needle visibility. We found that the use of Infiniti Plus decreased the median time to successfully place a femoral nerve catheter by 33% compared with not using Infiniti Plus. This difference may be more apparent to clinicians undertaking this procedure less often or by those in training as our team was very experienced, had been trained in the technique and was working in a hospital with a large caseload. Clinicaltrials.gov identifier: NCT02080481.
[Effect of modified Badenoch operation on the treatment of posterior urethral stricture].
Wang, Ping-xian; Zhang, Gen-pu; Huang, Chi-bing; Fan, Ming-qi; Feng, Jia-yu; Xiao, Ya
2012-02-01
To determine the effects of modified pull-through operation (Badenoch operation) on the treatment of posterior urethral stricture. From September 2001 to December 2010 traditional pull-through operation was Modified for two times in our center. A total of 129 patients with posttraumatic posterior urethral stricture resulting from pelvic fracture injury underwent the modified urethral pull-through operation. Stricture length was 1.5 to 5.3 cm (mean 2.9 cm). Of the patients 43 had undergone at least 1 previous failed management for stricture. In phase 1 (from September 2001 to January 2008), the improving items include: (1) The distal urethral end was stitched and tied to the catheter. (2) As catheter was inserted into bladder and 20 ml water was injected into catheter balloon, the distal urethral end was fixed in the proximal urethra and an overlaying of 1.5 cm was formed between the two ends. (3) Three weeks later, it was tried to insert the catheter to bladder. After the urethral stump necrosis and the catheter separating from the urethra, the catheter was removed. In phase 2 (from February 2008 to December 2010), based on the above, irrigating catheter was used. After the surgery, urethra was irrigated with 0.02% furacillin solution through the catheter 3 times a day. All patients were followed up for at least 6 months. If patients had no conscious dysuria and maximum urinary flow rate (Qmax) > 15 ml/s, the treatment was considered successful. All complications were recorded. In phase 1, the 96 patients (101 times) underwent the procedure. The treatment was successful in 88 patients (success rate 92%). Within 1 to 13 days after removal of the catheter, urethral stricture was recurred in 8 patients. They had to undergo cystostomy once more for 3 to 11 months before reoperation (the 3 patients' reoperation was in phase 2). The 8 cases were treated successfully. In phase 2, 33 patients (total 36 times) underwent the procedure. One patient was failed (success rate 97%). The actual follow-up time is 7 to 93 months (An average of 37.6 months). Qmax is (22 ± 5) ml/s. No complications such as urinary incontinence, erectile pain, urinary shortening happened. The modified urethral pull-through operation is effective for the surgical treatment of posttraumatic posterior urethral stricture. It has a high success rate with durable long-term results. Complications are few. The procedure is simple, less demanding and especially suitable in patients who had previously undergone failed surgical treatments.
Peak-locking centroid bias in Shack-Hartmann wavefront sensing
NASA Astrophysics Data System (ADS)
Anugu, Narsireddy; Garcia, Paulo J. V.; Correia, Carlos M.
2018-05-01
Shack-Hartmann wavefront sensing relies on accurate spot centre measurement. Several algorithms were developed with this aim, mostly focused on precision, i.e. minimizing random errors. In the solar and extended scene community, the importance of the accuracy (bias error due to peak-locking, quantization, or sampling) of the centroid determination was identified and solutions proposed. But these solutions only allow partial bias corrections. To date, no systematic study of the bias error was conducted. This article bridges the gap by quantifying the bias error for different correlation peak-finding algorithms and types of sub-aperture images and by proposing a practical solution to minimize its effects. Four classes of sub-aperture images (point source, elongated laser guide star, crowded field, and solar extended scene) together with five types of peak-finding algorithms (1D parabola, the centre of gravity, Gaussian, 2D quadratic polynomial, and pyramid) are considered, in a variety of signal-to-noise conditions. The best performing peak-finding algorithm depends on the sub-aperture image type, but none is satisfactory to both bias and random errors. A practical solution is proposed that relies on the antisymmetric response of the bias to the sub-pixel position of the true centre. The solution decreases the bias by a factor of ˜7 to values of ≲ 0.02 pix. The computational cost is typically twice of current cross-correlation algorithms.
Quick-Change Anode for Plating
NASA Technical Reports Server (NTRS)
Beasley, J. L.
1987-01-01
Proposed fastener for attaching electroplating anode improves quality of plating and increases productivity. Notches in twist-lock fastener mates with projections on end of anode bar. Fastener made of titanium for compatibility with copper-plating solution. Also constructed in snap-on, snap-off configuration.
NASA Astrophysics Data System (ADS)
Yun, Cheol-Ho; Yeo, Leslie Y.; Friend, James R.; Yan, Bernard
2012-04-01
A 240-μm diameter ultrasonic micromotor is presented as a potential solution for an especially difficult task in minimally invasive neurosurgery, navigating a guidewire to an injury in the neurovasculature as the first step of surgery. The peak no-load angular velocity and maximum torque were 600 rad/s and 1.6 nN-m, respectively, and we obtained rotation about all three axes. By using a burst drive scheme, open-loop position and speed control were achieved. The construction method and control scheme proposed in this study remove most of the current limitations in minimally invasive, catheter-based actuation, enabling minimally invasive vascular surgery concepts to be pursued for a broad variety of applications.
D'Antonio, D; Parruti, G; Pontieri, E; Di Bonaventura, G; Manzoli, L; Sferra, R; Vetuschi, A; Piccolomini, R; Romano, F; Staniscia, T
2004-10-01
In order to expand the present knowledge of the pathogenic potential of Blastoschizomyces capitatus in central venous catheter (CVC)-related bloodstream infections, six strains of the organism recovered from three leukemic patients with CVC-related fungemia in different years were investigated. Isolates and control strains were tested for their genetic relatedness and for their ability to produce slime in glucose-containing solutions. DNA restriction enzyme analysis revealed that all strains of B. capitatus were identical, whereas slime production assays and examination of ex vivo material showed that they were able to produce large amounts of slime. Slime production may therefore play a relevant pathogenic role in cases of CVC-related fungemia caused by B. capitatus.
Collaborative Research: Robust Climate Projections and Stochastic Stability of Dynamical Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ilya Zaliapin
This project focused on conceptual exploration of El Nino/Southern Oscillation (ENSO) variability and sensitivity using a Delay Differential Equation developed in the project. We have (i) established the existence and continuous dependence of solutions of the model (ii) explored multiple models solutions, and the distribution of solutions extrema, and (iii) established and explored the phase locking phenomenon and the existence of multiple solutions for the same values of model parameters. In addition, we have applied to our model the concept of pullback attractor, which greatly facilitated predictive understanding of the nonlinear model's behavior.
Zhu, Zhiling; Yu, Fei; Chen, Haoqing; Wang, Jun; Lopez, Analette I; Chen, Quan; Li, Siheng; Long, Yuyu; Darouiche, Rabih O; Hull, Richard A; Zhang, Lijuan; Cai, Chengzhi
2017-12-01
Bacterial interference using non-pathogenic Escherichia coli 83972 is a novel strategy for preventing catheter-associated urinary tract infection (CAUTI). Crucial to the success of this strategy is to establish a high coverage and stable biofilm of the non-pathogenic bacteria on the catheter surface. However, this non-pathogenic strain is sluggish to form biofilms on silicone as the most widely used material for urinary catheters. We have addressed this issue by modifying the silicone catheter surfaces with mannosides that promote the biofilm formation, but the stability of the non-pathogenic biofilms challenged by uropathogens over long-term remains a concern. Herein, we report our study on the stability of the non-pathogenic biofilms grown on propynylphenyl mannoside-modified silicone. The result shows that 94% non-pathogenic bacteria were retained on the modified silicone under >0.5 Pa shear stress. After being challenged by three multidrug-resistant uropathogenic isolates in artificial urine for 11 days, large amounts (>4 × 10 6 CFU cm -2 ) of the non-pathogenic bacteria remained on the surfaces. These non-pathogenic biofilms reduced the colonization of the uropathogens by >3.2-log. In bacterial interference, the non-pathogenic Escherichia coli strains are sluggish to form biofilms on the catheter surfaces, due to rapid removal by urine flow. We have demonstrated a solution to this bottleneck by pre-functionalization of mannosides on the silicone surfaces to promote E. coli biofilm formation. A pre-conjugated high affinity propynylphenyl mannoside ligand tethered to the nanometric amino-terminated poly(amido amine) (PAMAM) dendrimer is used for binding to a major E. coli adhesin FimH. It greatly improves the efficiency for the catheter modification, the non-pathogenic biofilm coverage, as well as the (long-term) stability for prevention of uropathogen infections. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Parsha, Kaushik; Mir, Osman; Satani, Nikunj; Yang, Bing; Guerrero, Waldo; Mei, Zhuyong; Cai, Chunyan; Chen, Peng R; Gee, Adrian; Hanley, Patrick J; Aronowski, Jaroslaw; Savitz, Sean I
2017-01-01
Extensive animal data indicate that mesenchymal stromal cells (MSCs) improve outcome in stroke models. Intra-arterial (IA) injection is a promising route of delivery for MSCs. Therapeutic effect of MSCs in stroke is likely based on the broad repertoire of secreted trophic and immunomodulatory cytokines produced by MSCs. We determined the differential effects of exposing MSCs to different types of clinically relevant vehicles, and/or different additives and passage through a catheter relevant to IA injections. MSCs derived from human bone marrow were tested in the following vehicles: 5% albumin (ALB), 6% Hextend (HEX) and 40% dextran (DEX). Each solution was tested (i) alone, (ii) with low-dose heparin, (iii) with 10% Omnipaque, or (iv) a combination of heparin and Omnipaque. Cells in vehicles were collected directly or passed through an IA catheter, and MSC viability and cytokine release profiles were assessed. Cell viability remained above 90% under all tested conditions with albumin being the highest at 97%. Viability was slightly reduced after catheter passage or exposure to heparin or Omnipaque. Catheter passage had little effect on MSC cytokine secretion. ALB led to increased release of angiogenic factors such as vascular endothelial growth factor compared with other vehicles, while HEX and DEX led to suppression of pro-inflammatory cytokines such as interleukin-6. However, when these three vehicles were subjected to catheter passage and/or exposure to additives, the cytokine release profile varied depending on the combination of conditions to which MSCs were exposed. Exposure of MSCs to certain types of vehicles or additives changes the profile of cytokine secretion. The activation phenotype of MSCs may therefore be affected by the vehicles used for these cells or the exposure to the adjuvants used in their administration. Copyright © 2017 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.
Segura, M; Alía, C; Oms, L; Sancho, J J; Torres-Rodríguez, J M; Sitges-Serra, A
1989-01-01
We investigated in vitro the antibacterial properties of a simulated new hub model in which the female part has an antiseptic chamber through which the needle (male part) must pass before connection of the set and the catheter. To establish the time needed for disinfection, the magnitude of reduction of the contaminating inocula by the new hub model, and the antibacterial properties of the different components of the hub, we used needles contaminated with solutions containing high inocula (1.9 x 10(7) to 1.2 x 10(11) CFU/ml) of microorganisms involved in hub-related catheter sepsis. Sterilization of the needles was accomplished by allowing them to remain in the antiseptic chamber for 10 s in all assays with Staphylococcus epidermidis, Pseudomonas aeruginosa, Escherichia coli, and Candida albicans. The rubber closures limiting the antiseptic chamber and the dilution effect of the antiseptic itself accounted for a minor part of the inoculum reduction achieved by the new hub model. This simulated hub provides good protection against endoluminal contamination. Further studies seem warranted to prove its industrial viability and clinical efficacy. PMID:2512322
Menasché, P
1994-08-01
A pig model of cardiopulmonary bypass and cardioplegic arrest was used to compare leakage around manually inflatable and autoinflatable retrograde coronary sinus cardioplegia catheters. Warm and cold blood cardioplegia were alternately delivered through the catheter under study at both low (16 to 24 mm Hg) and high (30 to 40 mm Hg) perfusion pressures. During each experiment, the coronary sinus ostium was sealed around the shaft of the retrograde cannula so that all backflow occurring during cardioplegia delivery could be collected by a separate drainage catheter inserted directly into the coronary sinus approximately midway between the right atrium and the distal end of the balloon. Only two of the 52 manually inflatable cannulas leaked. The leakage in both cases was negligible (< 1% of the total retrograde cardioplegia flow). In contrast, leakage occurred with 57 of the 73 autoinflatable devices tested (p < 0.0001) and averaged 22% +/- 3% (mean +/- the standard error of the mean) of the total retrograde flow. The temperature of the cardioplegia solution had no effect on leakage. These results suggest that autoinflatable balloons inconsistently seal the coronary sinus during cardioplegia infusion, thereby decreasing the amount of flow that effectively reaches the myocardium. This should make surgeons cautious about using them with warm blood cardioplegia, which largely relies upon the delivery of sufficiently high retrograde nutritive flows for preventing cardioprotective aerobic arrest from becoming a life-threatening ischemic arrest.
Loubani, Osama M; Green, Robert S
2015-06-01
The aim of this study was to collect and describe all published reports of local tissue injury or extravasation from vasopressor administration via either peripheral intravenous (IV) or central venous catheter. A systematic search of Medline, Embase, and Cochrane databases was performed from inception through January 2014 for reports of adults who received vasopressor intravenously via peripheral IV or central venous catheter for a therapeutic purpose. We included primary studies or case reports of vasopressor administration that resulted in local tissue injury or extravasation of vasopressor solution. Eighty-five articles with 270 patients met all inclusion criteria. A total of 325 separate local tissue injury and extravasation events were identified, with 318 events resulting from peripheral vasopressor administration and 7 events resulting from central administration. There were 204 local tissue injury events from peripheral administration of vasopressors, with an average duration of infusion of 55.9 hours (±68.1), median time of 24 hours, and range of 0.08 to 528 hours. In most of these events (174/204, 85.3%), the infusion site was located distal to the antecubital or popliteal fossae. Published data on tissue injury or extravasation from vasopressor administration via peripheral IVs are derived mainly from case reports. Further study is warranted to clarify the safety of vasopressor administration via peripheral IVs. Copyright © 2015 Elsevier Inc. All rights reserved.
Biodegradable silk catheters for the delivery of therapeutics across anatomical repair sites.
Brown, Joseph E; Tozzi, Lorenzo; Schilling, Benjamin; Kelmendi-Doko, Arta; Truong, April B; Rodriguez, Maria J; Gil, Eun Seok; Sucsy, Robert; Valentin, Jolene E; Philips, Brian J; Marra, Kacey G; Rubin, J Peter; Kaplan, David L
2018-04-26
Biodegradable silk catheters for the delivery of therapeutics are designed with a focus on creating porous gradients that can direct the release of molecules away from the implantation site. Though suitable for a range of applications, these catheters are designed for drug delivery to transplanted adipose tissue in patients having undergone a fat grafting procedure. A common complication for fat grafts is the rapid reabsorption of large volume adipose transplants. In order to prolong volume retention, biodegradable catheters can be embedded into transplanted tissue to deliver nutrients, growth factors or therapeutics to improve adipocyte viability, proliferation, and ultimately extend volume retention. Two fabrication methods are developed: a silk gel-spinning technique, which uses a novel flash-freezing step to induce high porosity throughout the bulk of the tube, and a dip-coating process using silk protein solutions doped with a water soluble porogen. Increased porosity aids in the diffusion of drug through the silk tube in a controllable way. Additionally, we interface the porous tubes with ALZET osmotic pumps for implantation into a subcutaneous nude mouse model. The work described herein will discuss the processing parameters as well as the interfacing between pump and cargo therapeutic and the resulting release profiles. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2018. © 2018 Wiley Periodicals, Inc.
Peripheral intravenous nutrition without fat in neonatal surgery.
Coran, A G; Weintraub
1977-04-01
During a 1 yr period, 19 infants less than 2 mo of age were fed intravenously with an infusate composed of glucose, amino acids, electrolytes, and vitamins. The solution was infused at a rate of 200 ml/kg/day or more for periods ranging from 5-247 days. No central venous catheters were utilized; the solutions were always administered through a needle in a peripheral vein. Weight gains similar to those seen with other techniques of intravenous nutrition were observed in all of the patients studied. No instance of fluid overload in the form of pulmonary edema, peripheral edema, or congestive heart failure was seen, and osmotic diuresis was not observed because of the lower tonicity of the infusate. Phlebitis was seen in 1/5 of the infusions, but was reversed by stopping the infusion and applying warm soaks. Three cases of skin slough were observed and two of these healed spontaneously without the need of skin grafting. The advantages of this technique over central venous nutrition are the elimination of the complications related to the central venous catheter, namely, sepsis and superior vena cava thrombosis.
Stress evaluation in displacement-based 2D nonlocal finite element method
NASA Astrophysics Data System (ADS)
Pisano, Aurora Angela; Fuschi, Paolo
2018-06-01
The evaluation of the stress field within a nonlocal version of the displacement-based finite element method is addressed. With the aid of two numerical examples it is shown as some spurious oscillations of the computed nonlocal stresses arise at sections (or zones) of macroscopic inhomogeneity of the examined structures. It is also shown how the above drawback, which renders the stress numerical solution unreliable, can be viewed as the so-called locking in FEM, a subject debated in the early seventies. It is proved that a well known remedy for locking, i.e. the reduced integration technique, can be successfully applied also in the nonlocal elasticity context.
Thinking inside the (lock)box: using banking technology to improve the revenue cycle.
D'Eramo, Michael; Umbreit, Lynda
2005-08-01
An integrated, image-based lockbox solution has allowed Columbus, Ohio-based MaternOhio to automate payment posting, reconcilement, and billing; store check and remittance images electronically; and automatically update its in-house patient accounting system and medical records.
Figueiredo, Giovanna; Fiebig, Teresa; Kirschner, Stefanie; Nikoubashman, Omid; Kabelitz, Lisa; Othman, Ahmed; Nonn, Andrea; Kramer, Martin; Brockmann, Marc A.
2015-01-01
Background Repetitive administration of medication or contrast agents is frequently performed in mice. The introduction of vascular access mini-ports (VAMP) for mice allows long-term vascular catheterization, hereby eliminating the need for repeated vessel puncture. With catheter occlusion being the most commonly reported complication of chronic jugular vein catheterization, we tested whether digital subtraction angiography (DSA) can be utilized to evaluate VAMP patency in mice. Methods Twenty-three mice underwent catheterization of the jugular vein and subcutaneous implantation of a VAMP. The VAMP was flushed every second day with 50 μL of heparinized saline solution (25 IU/ml). DSA was performed during injection of 100 μL of an iodine based contrast agent using an industrial X-ray inspection system intraoperatively, as well as 7±2 and 14±2 days post implantation. Results DSA allowed localization of catheter tip position, to rule out dislocation, kinking or occlusion of a microcatheter, and to evaluate parent vessel patency. In addition, we observed different ante- and retrograde collateral flow patterns in case of jugular vein occlusion. More exactly, 30% of animals showed parent vessel occlusion after 7±2 days in our setting. At this time point, nevertheless, all VAMPs verified intravascular contrast administration. After 14±2 days, intravascular contrast injection was verified in 70% of the implanted VAMPs, whereas at this point of time 5 animals had died or were sacrificed and in 2 mice parent vessel occlusion hampered intravascular contrast injection. Notably, no occlusion of the catheter itself was observed. Conclusion From our observations we conclude DSA to be a fast and valuable minimally invasive tool for investigation of catheter and parent vessel patency and for anatomical studies of collateral blood flow in animals as small as mice. PMID:26098622
Hishinuma, S.; Uchida, M. K.
1987-01-01
1 Short-term desensitization to histamine was induced by incubating guinea-pig taenia caecum with 10(-4)M histamine for 30 min (desensitizing incubation) in normal Locke-Ringer solution or Ca-free Locke-Ringer solution containing 0.2 mM EGTA. This desensitization was measured as a reduction of the maximal contractile response. 2 The effects of the presence of local anaesthetics during the desensitizing incubation were examined. Results showed that tetracaine, procaine, procainamide, oxybuprocaine and lignocaine inhibited the desensitization, whereas dibucaine, benzocaine and mepivacaine did not. 3 The inhibitory effects of these drugs on the desensitization were not correlated with their lipid solubility nor with the potency of their known effects, such as membrane stabilization, Ca channel blockade, calmodulin antagonism, or inhibition of C-kinase. 4 It is concluded that the inhibitory effects of local anaesthetics on the desensitization are not due to their non-specific membrane-stabilizing effects per se, but to some other action. PMID:3427278
[Biological activity evaluation of porous HA ceramics using NH4 HCO3/PVA as pore-creating agents].
Wang, Songquan; Zhang, Dekun
2010-12-01
Porous HA ceramics were prepared by using NH4 HCO3/PVA as pore-formed material along with biological glass as intensifier, and these ceramics were immersed in Locke's Physiological Saline and Simulate Body Fluid (SBF). The changes of phase composition, grain size and crystallinity of porous HA ceramics before and after immersion were investigated by X-Ray Diffraction (XRD) and Scanning Electron Microscopy (SEM). The biological activity was evaluated. The porous HA ceramics showed various degrees of decomposition after immersion in the two solution systems, but there was no evident change in respect to crystallinity. Besides, the impact of different degrees of solution systems on the change of grain size and planar preferred orientation was observed. The TCP phase of the ceramics immersed in Locke's Physiological Saline decomposed and there was no crystal growth on the surface of ceramics; however, the grain size of ceramics immersed in SBF became refined in certain degree and the surface of ceramics took on the new crystal growth.
A renormalization group model for the stick-slip behavior of faults
NASA Technical Reports Server (NTRS)
Smalley, R. F., Jr.; Turcotte, D. L.; Solla, S. A.
1983-01-01
A fault which is treated as an array of asperities with a prescribed statistical distribution of strengths is described. For a linear array the stress is transferred to a single adjacent asperity and for a two dimensional array to three ajacent asperities. It is shown that the solutions bifurcate at a critical applied stress. At stresses less than the critical stress virtually no asperities fail on a large scale and the fault is locked. At the critical stress the solution bifurcates and asperity failure cascades away from the nucleus of failure. It is found that the stick slip behavior of most faults can be attributed to the distribution of asperities on the fault. The observation of stick slip behavior on faults rather than stable sliding, why the observed level of seismicity on a locked fault is very small, and why the stress on a fault is less than that predicted by a standard value of the coefficient of friction are outlined.
Design and Implementation of an RTK-Based Vector Phase Locked Loop
Shafaati, Ahmad; Lin, Tao; Broumandan, Ali; Lachapelle, Gérard
2018-01-01
This paper introduces a novel double-differential vector phase-locked loop (DD-VPLL) for Global Navigation Satellite Systems (GNSS) that leverages carrier phase position solutions as well as base station measurements in the estimation of rover tracking loop parameters. The use of double differencing alleviates the need for estimating receiver clock dynamics and atmospheric delays; therefore, the navigation filter consists of the baseline dynamic states only. It is shown that using vector processing for carrier phase tracking leads to a significant enhancement in the receiver sensitivity compared to using the conventional scalar-based tracking loop (STL) and vector frequency locked loop (VFLL). The sensitivity improvement of 8 to 10 dB compared to STL, and 7 to 8 dB compared to VFLL, is obtained based on the test cases reported in the paper. Also, an increased probability of ambiguity resolution in the proposed method results in better availability for real time kinematic (RTK) applications. PMID:29533994
Rodman, J S; Reckler, J M; Israel, A R
1981-08-01
Following surgery for branched renal calculi, hemiacidrin irrigation may be useful to dissolve any residual stones. Struvite, the mineral in these stones, is itself an alkaline buffer and can raise the pH of the irrigating solution rendering it ineffective. Large volumes of hemiacidrin must reach the stone remnants or they are unlikely to dissolve. Two cases are described in which creative positioning of the patient or the irrigation catheters was necessary to permit adequate amounts of hemiacidrin to reach and dissolve stone remnants.
Do You Lock Your Network Doors? Some Network Management Precautions.
ERIC Educational Resources Information Center
Neray, Phil
1997-01-01
Discusses security problems and solutions for networked organizations with Internet connections. Topics include access to private networks from electronic mail information; computer viruses; computer software; corporate espionage; firewalls, that is computers that stand between a local network and the Internet; passwords; and physical security.…
Wieczorowska-Tobis, K; Polubinska, A; Breborowicz, A; Oreopoulos, D G
2001-01-01
Phosphate-buffered saline (PBS), an isotonic solution with a physiologic pH can be considered an example of a biocompatible dialysis fluid. This study compared the biocompatibility of PBS with that of Dianeal 3.86% (Baxter Healthcare Corporation, Deerfield, IL, U.S.A.), using a model of peritoneal dialysis in the rat. In an acute experiment, after catheter implantation, rats were infused on day 1 with PBS, on day 5 with standard dialysis solution (Dianeal 3.86%), and on day 7 again with PBS. When rats were injected with Dianeal 3.86%, the inflammatory reaction was suppressed as compared with PBS. The cell count was lower with Dianeal (-85%, p < 0.001), the neutrophil:macrophage ratio in dialysate was 80% lower (p < 0.01), total protein concentration in the Dianeal dialysate was 73% lower (p < 0.01), and the dialysate nitrite level was 45% lower (p < 0.01). In a chronic experiment, after catheter implantation, rats were dialyzed for four weeks with PBS or with Dianeal 3.86%. At the end of the study, a 1-hour peritoneal equilibration test (PET) was performed. As evaluated on a semiquantitative scale, macroscopic changes in the peritoneum were more severe in rats exposed to PBS than in those exposed to Dianeal 3.86% (8.6 +/- 3.2 vs 5.2 +/- 2.6, p < 0.05). The thickness of the visceral peritoneum was comparable in both groups; but, in PBS-treated rats, the peritoneal interstitium contained more inflammatory cells and more new vessels. During the 1-hour PET, peritoneal permeability to water and solutes was comparable in the two groups. Despite a more physiologic composition, PBS is a less biocompatible peritoneal dialysis solutions than is standard, acidic, hypertonic dialysis solution.
Mendoza-Guevara, L; Castro-Vazquez, F; Aguilar-Kitsu, A; Morales-Nava, A; Rodriguez-Leyva, F; Sanchez-Barbosa, J L
2007-01-01
Although, decreasing in incidence with the disconnection systems, the first complication is still peritonitis in patients with chronic renal failure and the second is infection of Tenckhoff catheter exit-site. All efforts made to diminish the frequency of exit-site infection lower the possibility of peritonitis. The pediatric population is well-known to have a major risk of infectious complications, and making easy and safe the care of the exit-site will prevent the peritonitis that follows. The aim of the study was to evaluate the efficacy of the Amuchina 10% solution vs. pH neutral soap in children with chronic renal failure, on preventing exit-site infection. There were 60 patients who were assigned randomly to one of two groups. One group used Amuchina 10% solution for the daily cleaning of the exit-site, and the other used pH neutral soap, with 14 months of follow-up. Before the study they have to be free of infection for at least 30 days. All were taught by the same nurse how to clean their exit-site. Groups were almost identical in years, sex, and time on dialysis. We had nine infections in the soap group and none in the Amuchina 10% solution group, with an OR: 17 (p = 0.004). From these nine infections, the bacteria isolated were: 4 (13%) were caused by Pseudomona aeruginosa, 1 (3.3%) by Staphylococcus aureus, coagulase-positive staphylococci in 2 (6.6%) and Serratia marcensens in 1 (3.3%). In conclusion, Amuchina 10% solution is effective in preventing infection on the exit-site, without any secondary topical reaction.
1987-03-01
ACID 2DO 190 ISO 1 70 160 150 140 a’ 130 O 120 110 100 - 90 so 70 60 50 40 30 20 10 0 0 20 40 60 so 100 STRAIN RATE (1/SEC) 0 0 x + 20 X 0 40 X .6 60 x...preliminary investigation, dilute solutions (2-10 V%) of an organic (furfuryl alcohol based) resin in iso -propyl alcohol were prepared. SiC whiskers were then...Locke Stepped-Temperature Stress Rupture STSR-NGK LOCKE ISO * 100 U200 t100 12000 .lU /l 24HRS. , 1100 w300 22 4 HR S . = 1000 4400 900 450 350 24HRS
Three-dimensional flat shell-to-shell coupling: numerical challenges
NASA Astrophysics Data System (ADS)
Guo, Kuo; Haikal, Ghadir
2017-11-01
The node-to-surface formulation is widely used in contact simulations with finite elements because it is relatively easy to implement using different types of element discretizations. This approach, however, has a number of well-known drawbacks, including locking due to over-constraint when this formulation is used as a twopass method. Most studies on the node-to-surface contact formulation, however, have been conducted using solid elements and little has been done to investigate the effectiveness of this approach for beam or shell elements. In this paper we show that locking can also be observed with the node-to-surface contact formulation when applied to plate and flat shell elements even with a singlepass implementation with distinct master/slave designations, which is the standard solution to locking with solid elements. In our study, we use the quadrilateral four node flat shell element for thin (Kirchhoff-Love) plate and thick (Reissner-Mindlin) plate theory, both in their standard forms and with improved formulations such as the linked interpolation [1] and the Discrete Kirchhoff [2] elements for thick and thin plates, respectively. The Lagrange multiplier method is used to enforce the node-to-surface constraints for all elements. The results show clear locking when compared to those obtained using a conforming mesh configuration.
Castellano, Fabrizio; Li, Lianhe; Linfield, Edmund H; Davies, A Giles; Vitiello, Miriam S
2016-03-15
Mode-locked comb sources operating at optical frequencies underpin applications ranging from spectroscopy and ultrafast physics, through to absolute frequency measurements and atomic clocks. Extending their operation into the terahertz frequency range would greatly benefit from the availability of compact semiconductor-based sources. However, the development of any compact mode-locked THz laser, which itself is inherently a frequency comb, has yet to be achieved without the use of an external stimulus. High-power, electrically pumped quantum cascade lasers (QCLs) have recently emerged as a promising solution, owing to their octave spanning bandwidths, the ability to achieve group-velocity dispersion compensation and the possibility of obtaining active mode-locking. Here, we propose an unprecedented compact architecture to induce both frequency and amplitude self-modulation in a THz QCL. By engineering a microwave avalanche oscillator into the laser cavity, which provides a 10 GHz self-modulation of the bias current and output power, we demonstrate multimode laser emission centered around 3 THz, with distinct multiple sidebands. The resulting microwave amplitude and frequency self-modulation of THz QCLs opens up intriguing perspectives, for engineering integrated self-mode-locked THz lasers, with impact in fields such as nano- and ultrafast photonics and optical metrology.
Castellano, Fabrizio; Li, Lianhe; Linfield, Edmund H.; Davies, A. Giles; Vitiello, Miriam S.
2016-01-01
Mode-locked comb sources operating at optical frequencies underpin applications ranging from spectroscopy and ultrafast physics, through to absolute frequency measurements and atomic clocks. Extending their operation into the terahertz frequency range would greatly benefit from the availability of compact semiconductor-based sources. However, the development of any compact mode-locked THz laser, which itself is inherently a frequency comb, has yet to be achieved without the use of an external stimulus. High-power, electrically pumped quantum cascade lasers (QCLs) have recently emerged as a promising solution, owing to their octave spanning bandwidths, the ability to achieve group-velocity dispersion compensation and the possibility of obtaining active mode-locking. Here, we propose an unprecedented compact architecture to induce both frequency and amplitude self-modulation in a THz QCL. By engineering a microwave avalanche oscillator into the laser cavity, which provides a 10 GHz self-modulation of the bias current and output power, we demonstrate multimode laser emission centered around 3 THz, with distinct multiple sidebands. The resulting microwave amplitude and frequency self-modulation of THz QCLs opens up intriguing perspectives, for engineering integrated self-mode-locked THz lasers, with impact in fields such as nano- and ultrafast photonics and optical metrology. PMID:26976199
Relieving menstrual obstruction: surgical correction of vaginal agenesis.
Schmitt, Jennifer J; Arora, Chetna; Gebhart, John B
2016-04-01
Mayer-Rokitansky-Küster-Hauser (MRKH) syndrome includes vaginal agenesis with varied uterine development. The objective of this video is to illustrate our surgical technique to create a cervical and vaginal canal to relieve menstrual obstruction for a teenager with a functional uterus and vaginal agenesis. Using vaginal dissection and a mini laparotomy, a sound placed through the fundus of the uterus created an endocervical and vaginal channel to relieve her menstrual obstruction. A Foley catheter stented the cervical canal and a red rubber chest tube catheter stented the vagina until epithelization was achieved. No complications were encountered. The patient was examined with intermittent hysteroscopy with gentle dilation of the cervix. She had the red rubber catheter removed at 3 months, and she started using a small dilator. Her menses were suppressed with a gonadotropin releasing-hormone agonist allowing for complete healing. She is now 17. Her vaginal canal is well-epithelialized. Hysteroscopy confirmed a patent endocervical canal and uterine cavity. MRKH is rare. A small percentage of affected women has a functional endometrium requiring intervention for menstrual obstruction. Full vaginal reconstruction may be considered, but creation of a small canal to provide menstrual relief can be a temporary solution in those not desiring sexual function.
Heartbeat OCT: in vivo intravascular megahertz-optical coherence tomography
Wang, Tianshi; Pfeiffer, Tom; Regar, Evelyn; Wieser, Wolfgang; van Beusekom, Heleen; Lancee, Charles T.; Springeling, Geert; Krabbendam, Ilona; van der Steen, Antonius F.W.; Huber, Robert; van Soest, Gijs
2015-01-01
Cardiac motion artifacts, non-uniform rotational distortion and undersampling affect the image quality and the diagnostic impact of intravascular optical coherence tomography (IV-OCT). In this study we demonstrate how these limitations of IV-OCT can be addressed by using an imaging system that we called “Heartbeat OCT”, combining a fast Fourier Domain Mode Locked laser, fast pullback, and a micromotor actuated catheter, designed to examine a coronary vessel in less than one cardiac cycle. We acquired in vivo data sets of two coronary arteries in a porcine heart with both Heartbeat OCT, working at 2.88 MHz A-line rate, 4000 frames/s and 100 mm/s pullback speed, and with a commercial system. The in vivo results show that Heartbeat OCT provides faithfully rendered, motion-artifact free, fully sampled vessel wall architecture, unlike the conventional IV-OCT data. We present the Heartbeat OCT system in full technical detail and discuss the steps needed for clinical translation of the technology. PMID:26713214
Issues Involved in Developing Ada Real-Time Systems
1989-02-15
expensive modifications to the compiler or Ada runtime system to fit a particular application. Whether we can solve the problems of programming real - time systems in...lock in solutions to problems that are not yet well understood in standards as rigorous as the Ada language. Moreover, real - time systems typically have
ERIC Educational Resources Information Center
Sokal, Laura
2016-01-01
Increasing enrolments of post-secondary students with disabilities are resulting in accessibility services offices reaching capacity levels. This trend has created the "perfect storm" in terms of meeting these students' needs. While collaboration between accessibility services staff and professors seems a logical solution to maximizing…
An Analysis of the Deployment of the 235th Aviation Company (Attack Helicopter)
1977-07-01
moves. Possible additional economies in future deployments of this nature are discussed in subsequent portions of this analysis. b. For this...tubes with water and clean the area in and around the horns with O-D-406, or equivalent, disinfectant- deodorant solution. f. Lock cyclic and
Quast, Michaela B; Sviggum, Hans P; Hanson, Andrew C; Stoike, David E; Martin, David P; Niesen, Adam D
2018-05-01
Continuous brachial plexus catheters are often used to decrease pain following elbow surgery. This investigation aimed to assess the rate of early failure of infraclavicular (IC) and axillary (AX) nerve catheters following elbow surgery. Retrospective study. Postoperative recovery unit and inpatient hospital floor. 328 patients who received IC or AX nerve catheters and underwent elbow surgery were identified by retrospective query of our institution's database. Data collected included unplanned catheter dislodgement, catheter replacement rate, postoperative pain scores, and opioid administration on postoperative day 1. Catheter failure was defined as unplanned dislodging within 24 h of placement or requirement for catheter replacement and evaluated using a covariate adjusted model. 119 IC catheters and 209 AX catheters were evaluated. There were 8 (6.7%) failed IC catheters versus 13 (6.2%) failed AX catheters. After adjusting for age, BMI, and gender there was no difference in catheter failure rate between IC and AX nerve catheters (p = 0.449). These results suggest that IC and AX nerve catheters do not differ in the rate of early catheter failure, despite differences in anatomic location and catheter placement techniques. Both techniques provided effective postoperative analgesia with median pain scores < 3/10 for patients following elbow surgery. Reasons other than rate of early catheter failure should dictate which approach is performed. Copyright © 2018. Published by Elsevier Inc.
Robotic positioning of standard electrophysiology catheters: a novel approach to catheter robotics.
Knight, Bradley; Ayers, Gregory M; Cohen, Todd J
2008-05-01
Robotic systems have been developed to manipulate and position electrophysiology (EP) catheters remotely. One limitation of existing systems is their requirement for specialized catheters or sheaths. We evaluated a system (Catheter Robotics Remote Catheter Manipulation System [RCMS], Catheter Robotics, Inc., Budd Lake, New Jersey) that manipulates conventional EP catheters placed through standard introducer sheaths. The remote controller functions much like the EP catheter handle, and the system permits repeated catheter disengagement for manual manipulation without requiring removal of the catheter from the body. This study tested the hypothesis that the RCMS would be able to safely and effectively position catheters at various intracardiac sites and obtain thresholds and electrograms similar to those obtained with manual catheter manipulation. Two identical 7 Fr catheters (Blazer II; Boston Scientific Corp., Natick, Massachusetts) were inserted into the right femoral veins of 6 mongrel dogs through separate, standard 7 Fr sheaths. The first catheter was manually placed at a right ventricular endocardial site. The second catheter handle was placed in the mating holder of the RCMS and moved to approximately the same site as the first catheter using the Catheter Robotics RCMS. The pacing threshold was determined for each catheter. This sequence was performed at 2 right atrial and 2 right ventricular sites. The distance between the manually and robotically placed catheters tips was measured, and pacing thresholds and His-bundle recordings were compared. The heart was inspected at necropsy for signs of cardiac perforation or injury. Compared to manual positioning, remote catheter placement produced the same pacing threshold at 7/24 sites, a lower threshold at 11/24 sites, and a higher threshold at only 6/24 sites (p > 0.05). The average distance between catheter tips was 0.46 +/- 0.32 cm (median 0.32, range 0.13-1.16 cm). There was no difference between right atrial and right ventricular sites (p > 0.05). His-bundle electrograms were equal in amplitude and timing. Further, the remote navigation catheter was able to be disengaged, manually manipulated, then reengaged in the robot without issue. There was no evidence of perforation. The Catheter Robotics remote catheter manipulation system, which uses conventional EP catheters and introducer sheaths, appears to be safe and effective at directing EP catheters to intracardiac sites and achieving pacing thresholds and electrograms equivalent to manually placed catheters. Further clinical studies are needed to confirm these observations.
Hasegawa, S; Nakashima, J; Kimura, S
1987-08-01
To control post-operative bleeding from the resected cavity in transurethral resection of the prostate (TUR-P), 20,000 units of thrombin dissolved in 5-20 ml of physiological saline was injected into the cavity in one shot with a new type of 3-way Foley catheter. The catheter has two holes close to the balloon, and the holes provide outlets through which the solution is directly injected into the cavity. Out of 23 patients between 58 and 87 years old, 11 were given thrombin and 12 were control cases. In each case, urine blood volume (ml/hr) was determined before (a) and after (b) injection. The hemostatic effect was assessed with a "hemostatic index" of b/a. There was a statistically significant difference in the hemostatic indices between thrombin group and the control. (p less than 0.02) This new hemostatic method proved to be a very useful easy bed-side technique to control bleeding even in sudden bleeding after TUR-P. No serious side effects were found during the course of this study.
Hemodialysis Tunneled Catheter Noninfectious Complications
Miller, Lisa M.; MacRae, Jennifer M.; Kiaii, Mercedeh; Clark, Edward; Dipchand, Christine; Kappel, Joanne; Lok, Charmaine; Luscombe, Rick; Moist, Louise; Oliver, Matthew; Pike, Pamela; Hiremath, Swapnil
2016-01-01
Noninfectious hemodialysis catheter complications include catheter dysfunction, catheter-related thrombus, and central vein stenosis. The definitions, causes, and treatment strategies for catheter dysfunction are reviewed below. Catheter-related thrombus is a less common but serious complication of catheters, requiring catheter removal and systemic anticoagulation. In addition, the risk factors, clinical manifestation, and treatment options for central vein stenosis are outlined. PMID:28270922
Investigation and Development of Air Foam Cushioning
1975-06-01
n.c..#arr and lafenrffr or »lock numb«) CUSHIONING MATERIALS PACKAGING MATERIILS POLYURETHANE FOAM CUSHIONING SOLUTIONS ( AQUEOUS ) POLYMERS FOAMING ...Mixer. This froth foam could be produced by pour-in-place method or could be made into pre- formed and cut ribbon DD, ET» M73 EDITION OF I NOV SI IS...hours« The foam did not recover after the weight was removed« Work on the foaming of polyvinyl alcohol solution with an Oakes Mixer produced a spongy
Moss, H A; Tebbs, S E; Faroqui, M H; Herbst, T; Isaac, J L; Brown, J; Elliott, T S
2000-11-01
In an attempt to overcome infections associated with central venous catheters, a new antiseptic central venous catheter coated with benzalkonium chloride on the internal and external surfaces has been developed and evaluated in a clinical trial. Patients (235) randomly received either a triple-lumen central venous catheter coated with benzalkonium chloride (117) or a polyurethane non-antiseptic catheter (118). The incidence of microbial colonization of both catheters and retained antiseptic activity of the benzalkonium chloride device following removal were determined. The benzalkonium chloride resulted in a significant reduction of the incidence of microbial colonization on both the internal and external catheter surfaces. The reduction in colonization was detected at both the intradermal (21 benzalkonium chloride catheters vs. 38 controls, P = 0.0016) and distal segments of the antiseptic-coated catheters. Following catheter removal retained activity was demonstrated in benzalkonium chloride catheters which had been in place for up to 12 days. No patients developed adverse reactions to the benzalkonium chloride catheters. The findings demonstrate that the benzalkonium chloride catheter significantly reduced the incidence of catheter-associated colonization.
Unsteady fluid flow in a slightly curved annular pipe: The impact of the annulus on the flow physics
NASA Astrophysics Data System (ADS)
Messaris, Gerasimos A. T.; Karahalios, George T.
2017-02-01
The motivation of the present study is threefold. Mainly, the etiological explanation of the Womersley number based on physical reasoning. Next, the extension of a previous work [Messaris, Hadjinicolaou, and Karahalios, "Unsteady fluid flow in a slightly curved pipe: A comparative study of a matched asymptotic expansions solution with a single analytical solution," Phys. Fluids 28, 081901 (2016)] to the annular pipe flow. Finally, the discussion of the effect of the additional stresses generated by a catheter in an artery and exerted on the arterial wall during an in vivo catheterization. As it is known, the square of the Womersley number may be interpreted as an oscillatory Reynolds number which equals to the ratio of the inertial to the viscous forces. The adoption of a modified Womersley number in terms of the annular gap width seems therefore more appropriate to the description of the annular flow than an ordinary Womersley number defined in terms of the pipe radius. On this ground, the non-dimensional equations of motion are approximately solved by two analytical methods: a matched asymptotic expansions method and a single. In the first method, which is valid for very large values of the Womersley number, the flow region consists of the main core and the two boundary layers formed at the inner and outer boundaries. In the second, the fluid is considered as one region and the Womersley number can vary from finite values, such that they fit to the blood flow in the aorta and the main arteries, to infinity. The single solution predicts increasing circumferential and decreasing axial stresses with increasing catheter radius at a prescribed value of the Womersley parameter in agreement with analogous results from other theoretical and numerical solutions. It also predicts the formation of pinches on the secondary flow streamlines and a third boundary layer, additional to those formed at the boundary walls. Finally, we show that the insertion of a catheter in an artery may trigger possible disastrous side effects. It may cause unexpected damage to a predisposed but still dormant location of the arterial wall due to high additional radial pressure that induces an excessive distension of the artery.
Krishnaiah, Anil; Soothill, James; Wade, Angie; Mok, Quen Q; Ramnarayan, Padmanabhan
2012-05-01
To compare the rate of central venous catheter-associated bloodstream infections between pediatric intensive care unit admissions where central venous catheters were inserted within the same hospital (internal central venous catheters) and those where central venous catheters were inserted before transfer from other hospitals (external central venous catheters). Retrospective analysis of prospectively collected data. A tertiary care pediatric intensive care unit in London, UK. Consecutive pediatric intensive care unit admissions between May 2007 and March 2009. None. Catheter-associated bloodstream infections were identified using a widely accepted surveillance definition. The rate and time to occurrence of catheter-associated bloodstream infection were compared between internal and external nontunneled central venous catheters. A multilevel Cox-regression model was used to study the association between location of central venous catheter insertion and time to catheter-associated bloodstream infection. In total, 382 central venous catheters were studied (245 internal; 137 external) accounting for a total of 1,737 central venous catheter days. There was a higher catheter-associated bloodstream infection incidence density among external central venous catheters (23.1 [95% confidence interval 11.0-35.2] vs. 9.7 [95% confidence interval 3.9-15.5] per 1,000 catheter-days). Multivariable analyses demonstrated higher infection risk with external central venous catheters (hazard ratio 2.65 [95% confidence interval 1.18-5.96]) despite adjustment for confounding variables. The rate of catheter-associated bloodstream infections in the pediatric intensive care unit is significantly affected by external insertion of the central venous catheter. Future interventions to reduce nosocomial infections on pediatric intensive care units will need to be specifically targeted at this high-risk patient group.
Fan, Qiyong; Yeung, Anamaria R; Amdur, Robert; Helmig, Richard; Park, Justin; Li, Jonathan; Kahler, Darren; Liu, Chihray; Lu, Bo
2017-06-01
The efficacy of image-guided high-dose rate brachytherapy for cervical cancer is limited by the ineffective rectal sparing devices available commercially and the potential applicator movement. We developed a novel device using a balloon catheter and a belt immobilization system, serving for rectal dose reduction and applicator immobilization purposes, respectively. The balloon catheter is constructed by gluing a short inflatable tube to a long regular open-end catheter. Contrast agent (10) cm 3 is injected into the inflatable end, which is affixed to the tandem and ring applicator, to displace the posterior vaginal wall. The belt immobilization system consists of a specially designed bracket that can hold and fix itself to the applicator, a diaper-like Velcro fastener package used for connecting the patient's pelvis to the bracket, and a buckle that holds the fasteners to stabilize the whole system. The treatment data for 21 patients with cervical cancer using both balloon catheter and belt immobilization system were retrospectively analyzed. Computed tomography and magnetic resonance images, acquired about 30 minutes apart, were registered to evaluate the effectiveness of the immobilization system. In comparison with a virtual rectal blade, the balloon decreased the rectal point dose by 34% ± 4.2% (from 276 ± 57 to 182 ± 38 cGy), corresponding to an extra sparing distance of 7.9 ± 1.1 mm. The maximum sparing distance variation per patient is 1.4 ± 0.6 mm, indicating the high interfractional reproducibility for rectum sparing. With the immobilization system, the mean translational and rotational displacements of the applicator set are <3 mm and <1.5°, respectively, in all directions. The rectal balloon provides significant dose reduction to the rectum and it may potentially minimize patient discomfort. The immobilization system permits almost no movement of the applicator during treatment. This work has the potential to be promoted as a standardized solution for high-dose rate treatment of cervical cancer.
Equity and Access in Charter Schools: Identifying Issues and Solutions
ERIC Educational Resources Information Center
Marshall, David T.
2017-01-01
School choice exists in American public schooling, even where official school choice policy is absent. Parents with means can elect to live in neighborhoods zoned for desirable schools, whereas parents without means are locked out of that opportunity. In their ideal, charter schools have the ability to expand access to desirable schools to…
Allan Bloom, America, and Education.
ERIC Educational Resources Information Center
West, Thomas
2000-01-01
Refutes the claims of Allan Bloom that the source of the problem with today's universities is modern philosophy, that the writings and ideas of Hobbes and Locke planted the seeds of relativism in American culture, and that the cure is Great Books education. Suggests instead that America's founding principles are the only solution to the failure of…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olejniczak, Lukasz; SUPELEC, OPTEL, and LMOPS EA 4423; Panajotov, Krassimir
2010-08-15
We study the dynamics of an optically injected quantum-dot laser accounting for excited states. Mapping of the bifurcations in the plane frequency detuning vs. injection strength shows that the relaxation rate scales the regions of locking and single- and double-period solutions, while the capture rate has a minor effect. Within the regions of time-periodic solutions, close to the saddle-node bifurcation boundary, we identify subregions where the output signal resembles excitable pulses as a result of the bottleneck phenomenon. We show that such emission is determined mainly by fluctuations in the occupation of the excited states. The interpulse time follows anmore » inverse square root scaling law as a function of the detuning. In a deterministic system the pulses are periodic regardless of the detuning, but in the presence of noise, close to the locking region, the interpulse time follows a positively skewed normal distribution. For a fixed frequency detuning, increasing the noise strength can shift the mean of the interpulse time distribution and make the pulsations more periodic.« less
Antibacterial and antibiofilm properties of yttrium fluoride nanoparticles
Lellouche, Jonathan; Friedman, Alexandra; Gedanken, Aharon; Banin, Ehud
2012-01-01
Antibiotic resistance has prompted the search for new agents that can inhibit bacterial growth. Moreover, colonization of abiotic surfaces by microorganisms and the formation of biofilms is a major cause of infections associated with medical implants, resulting in prolonged hospitalization periods and patient mortality. In this study we describe a water-based synthesis of yttrium fluoride (YF3) nanoparticles (NPs) using sonochemistry. The sonochemical irradiation of an aqueous solution of yttrium (III) acetate tetrahydrate [Y(Ac)3 · (H2O)4], containing acidic HF as the fluorine ion source, yielded nanocrystalline needle-shaped YF3 particles. The obtained NPs were characterized by scanning electron microscopy and X-ray elemental analysis. NP crystallinity was confirmed by electron and powder X-ray diffractions. YF3 NPs showed antibacterial properties against two common bacterial pathogens (Escherichia coli and Staphylococcus aureus) at a μg/mL range. We were also able to demonstrate that antimicrobial activity was dependent on NP size. In addition, catheters were surface modified with YF3 NPs using a one-step synthesis and coating process. The coating procedure yielded a homogeneous YF3 NP layer on the catheter, as analyzed by scanning electron microscopy and energy dispersive spectroscopy. These YF3 NP-modified catheters were investigated for their ability to restrict bacterial biofilm formation. The YF3 NP-coated catheters were able to significantly reduce bacterial colonization compared to the uncoated surface. Taken together, our results highlight the potential to further develop the concept of utilizing these metal fluoride NPs as novel antimicrobial and antibiofilm agents, taking advantage of their low solubility and providing extended protection. PMID:23152681
El-Guendouz, Soukaina; Aazza, Smail; Lyoussi, Badiaa; Bankova, Vassya; Lourenço, João P; Costa, Ana M Rosa; Mariano, José F; Miguel, Maria G; Faleiro, Maria L
2016-09-09
Biofilm bacteria are more resistant to antibiotics than planktonic cells. Propolis possesses antimicrobial activity. Generally, nanoparticles containing heavy metals possess antimicrobial and antibiofilm properties. In this study, the ability of adherence of Methicillin Resistant Strains of Staphylococcus aureus (MRSA) to catheters treated with magnetite nanoparticles (MNPs), produced by three methods and functionalized with oleic acid and a hydro-alcoholic extract of propolis from Morocco, was evaluated. The chemical composition of propolis was established by gas chromatography mass spectrometry (GC-MS), and the fabricated nanostructures characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), Mossbauer spectroscopy and Fourrier transform infrared spectroscopy (FTIR). The capacity for impairing biofilm formation was dependent on the strain, as well as on the mode of production of MNPs. The co-precipitation method of MNPs fabrication using Fe(3+) and Na₂SO₃ solution and functionalized with oleic acid and propolis was the most effective in the impairment of adherence of all MRSA strains to catheters (p < 0.001). The adherence of the strain MRSA16 was also significantly lower (p < 0.001) when the catheters were treated with the hybrid MNPs with oleic acid produced by a hydrothermal method. The anti-MRSA observed can be attributed to the presence of benzyl caffeate, pinocembrin, galangin, and isocupressic acid in propolis extract, along with MNPs. However, for MRSA16, the impairment of its adherence on catheters may only be attributed to the hybrid MNPs with oleic acid, since very small amount, if any at all of propolis compounds were added to the MNPs.
Augusto, Renan Maloni; Albuquerque, André Luis Pereira; Jaeger, Thomas; de Carvalho, Carlos Roberto Ribeiro; Caruso, Pedro
2017-02-01
The use of esophageal catheters with microtransducer promises advantages over traditional catheters with air-filled balloons. However, performance comparisons between these 2 types of catheters are scarce and incomplete. A catheter with a 9.5-cm air-filled balloon at the distal tip and a catheter with a microtransducer mounted within a flexible silicone rubber were tested in vitro and in vivo. In vitro, the response times of both catheters were compared, and the drift of the baseline pressure of the microtransducer catheter was evaluated over a 6-h period. In vivo, 11 healthy volunteers had both catheters inserted, and the drift of the baseline esophageal pressure was measured over a 3-h period. Also, the correlation and agreement of the baseline and changes in the esophageal pressure of both catheters were evaluated. In vitro, the microtransducer catheter had a response time significantly higher (262 × 114 Hz, P < .01) and a good pressure stability, with a mean baseline pressure drift of 1.4 cm H 2 O. In vivo, both catheters presented a small and similar baseline esophageal pressure drift (P = 0.08). For measurements of baseline and changes in esophageal pressure, the correlation and agreement between the catheters were poor, with a large bias between them. The catheter with the microtransducer had a small baseline pressure drift, similar to the air-filled balloon catheter. The low agreement between the catheters does not allow the microtransducer catheter to be used as a surrogate for the traditional air-filled balloon catheter. Copyright © 2017 by Daedalus Enterprises.
Pigtail catheters used for percutaneous fluid drainage: comparison of performance characteristics.
Macha, Douglas B; Thomas, John; Nelson, Rendon C
2006-03-01
To compare the performance characteristics of various single-lumen all-purpose pigtail drainage catheters. The following parameters were compared: flow rates between catheters of the same size, whether changing the fluid viscosity has any effect on catheter comparisons, the effect on flow of leaving an open three-way stopcock in the drainage pathway, the tendency of the catheters to kink, and catheter patency after kinking, as measured according to flow. All-purpose 8.0-, 8.3-, and 8.5-F (collectively referred to as 8-F); 10.0-, 10.2-, and 10.3-F (collectively referred to as 10-F); and 12.0-F pigtail drainage catheters from three manufacturers were evaluated. Data were compared by using two-tailed t tests after normal distributions were confirmed. P < .05 was considered to represent a significant difference. At comparison of the 8-F catheters, the C.R. Bard catheters demonstrated better flow rates than the Cook and Boston Scientific devices. Among the 10-F catheters, there were no significant differences in the flow rates of fluid with viscosity equivalent to that of water between the C.R. Bard and Boston Scientific catheters; however, both these catheter types demonstrated significantly (P < .05) better flow rates than the Cook devices. Among the 12-F catheters, the C.R. Bard catheters demonstrated significantly (P < .05) better flow rates than the other two catheter types. Changing the fluid viscosity caused no changes in comparison results. In all catheter groups, the presence of a stopcock significantly (P < .05) impaired flow. None of the evaluated catheters demonstrated a clear advantage in terms of patency or susceptibility to kinking. At comparison of the in vitro performances of catheters from different manufacturers, the C.R. Bard 8.0-F and Cook 10.2-F catheters had comparable flow rates, and flow rates through the C.R. Bard and Boston Scientific 10.0-F catheters were comparable to flow rates through the Cook and Boston Scientific 12.0-F catheters. Varying viscosity had no effect on comparisons of catheter flow rates; however, a stopcock between the vacuum source and the catheter was noted to impair flow rates in all brands and sizes of evaluated catheters. Copyright RSNA, 2006.
Talreja, Hari; Ryan, Stephen Edward; Graham, Janet; Sood, Manish M.; Hadziomerovic, Adnan; Clark, Edward
2017-01-01
Background With the increasing frequency of tunneled hemodialysis catheter use there is a parallel increase in the need for removal and/or exchange. A small but significant minority of catheters become embedded or ‘stuck’ and cannot be removed by traditional means. Management of embedded catheters involves cutting the catheter, burying the retained fragment with a subsequent increased risk of infections and thrombosis. Endoluminal dilatation may provide a potential safe and effective technique for removing embedded catheters, however, to date, there is a paucity of data. Objectives 1) To determine factors associated with catheters becoming embedded and 2) to determine outcomes associated with endoluminal dilatation Methods All patients with endoluminal dilatation for embedded catheters at our institution since Jan. 2010 were included. Patients who had an embedded catheter were matched 1:3 with patients with uncomplicated catheter removal. Baseline patient and catheter characteristics were compared. Outcomes included procedural success and procedure-related infection. Logistic regression models were used to determine factors associated with embedded catheters. Results We matched 15 cases of embedded tunneled catheters with 45 controls. Among patients with embedded catheters, there were no complications with endoluminal dilatation. Factors independently associated with embedded catheters included catheter dwell time (> 2 years) and history of central venous stenosis. Conclusion Embedded catheters can be successfully managed by endoluminal dilatation with minimal complications and factors associated with embedding include dwell times > 2 years and/or with a history of central venous stenosis. PMID:28346468
WS2 mode-locked ultrafast fiber laser
Mao, Dong; Wang, Yadong; Ma, Chaojie; Han, Lei; Jiang, Biqiang; Gan, Xuetao; Hua, Shijia; Zhang, Wending; Mei, Ting; Zhao, Jianlin
2015-01-01
Graphene-like two dimensional materials, such as WS2 and MoS2, are highly anisotropic layered compounds that have attracted growing interest from basic research to practical applications. Similar with MoS2, few-layer WS2 has remarkable physical properties. Here, we demonstrate for the first time that WS2 nanosheets exhibit ultrafast nonlinear saturable absorption property and high optical damage threshold. Soliton mode-locking operations are achieved separately in an erbium-doped fiber laser using two types of WS2-based saturable absorbers, one of which is fabricated by depositing WS2 nanosheets on a D-shaped fiber, while the other is synthesized by mixing WS2 solution with polyvinyl alcohol, and then evaporating them on a substrate. At the maximum pump power of 600 mW, two saturable absorbers can work stably at mode-locking state without damage, indicating that few-layer WS2 is a promising high-power flexible saturable absorber for ultrafast optics. Numerous applications may benefit from the ultrafast nonlinear features of WS2 nanosheets, such as high-power pulsed laser, materials processing, and frequency comb spectroscopy. PMID:25608729
Yb-doped passively mode-locked fiber laser with Bi2Te3-deposited
NASA Astrophysics Data System (ADS)
Li, Lu; Yan, Pei-Guang; Wang, Yong-Gang; Duan, Li-Na; Sun, Hang; Si, Jin-Hai
2015-12-01
In this study we present an all-normal-dispersion Yb-doped fiber laser passively mode-locked with topological insulator (Bi2Te3) saturable absorber. The saturable absorber device is fabricated by depositing Bi2Te3 on a tapered fiber through using pulsed laser deposition (PLD) technology, which can give rise to less non-saturable losses than most of the solution processing methods. Owing to the long interaction length, Bi2Te3 is not exposed to high optical power, which allows the saturable absorber device to work in a high power regime. The modulation depth of this kind of saturable absorber is measured to be 10%. By combining the saturable absorber device with Yb-doped fiber laser, a mode-locked pulse operating at a repetition rate of 19.8 MHz is achieved. The 3-dB spectral width and pulse duration are measured to be 1.245 nm and 317 ps, respectively. Project supported by the National Natural Science Foundation of China (Grant No. 61378024) and the Natural Science Fund of Guangdong Province, China (Grant No. S2013010012235).
A pilot study to assess adductor canal catheter tip migration in a cadaver model.
Leng, Jody C; Harrison, T Kyle; Miller, Brett; Howard, Steven K; Conroy, Myles; Udani, Ankeet; Shum, Cynthia; Mariano, Edward R
2015-04-01
An adductor canal catheter may facilitate early ambulation after total knee arthroplasty, but there is concern over preoperative placement since intraoperative migration of catheters may occur from surgical manipulation and result in ineffective analgesia. We hypothesized that catheter type and subcutaneous tunneling may influence tip migration for preoperatively inserted adductor canal catheters. In a male unembalmed human cadaver, 20 catheter insertion trials were divided randomly into one of four groups: flexible epidural catheter either tunneled or not tunneled; or rigid stimulating catheter either tunneled or not tunneled. Intraoperative patient manipulation was simulated by five range-of-motion exercises of the knee. Distance and length measurements were performed by a blinded regional anesthesiologist. Changes in catheter tip to nerve distance (p = 0.225) and length of catheter within the adductor canal (p = 0.467) were not different between the four groups. Two of five non-tunneled stimulating catheters (40 %) were dislodged compared to 0/5 in all other groups (p = 0.187). A cadaver model may be useful for assessing migration of regional anesthesia catheters; catheter type and subcutaneous tunneling may not affect migration of adductor canal catheters based on this preliminary study. However, future studies involving a larger sample size, actual patients, and other catheter types are warranted.
General Solution for Theoretical Packet Data Loss Rate
NASA Technical Reports Server (NTRS)
Lansdowne, Chatwin; Schlesinger, Adam
2006-01-01
Communications systems which transfer blocks ("frames") of data must use a marker ("frame synchronization pattern") for identifying where a block begins. A technique ("frame synchronization strategy") is used to locate the start of each frame and maintain synchronization as additional blocks are processed. A device which strips out the frame synchronization pattern [FSP] and provides an "end of frame" pulse is called a frame synchronizer. As clock and data errors are introduced into the system, the start-of-block marker becomes displaced and/or corrupted. The capability of the frame synchronizer to stay locked to the pattern under these conditions is a figure of merit for the frame synchronization strategy. It is important to select a strategy which will stay locked nearly all the time at bit error rates where the data is usable. ("Bit error rate" [BER] is the fraction of binary bits which are inverted by passage through a communication system.) The fraction of frames that are discarded because the frame synchronizer is not locked is called "Percent Data Loss" or "Packet Data Loss rate" [PDL]. A general approach for accurately predicting PDL given BER was developed in Theoretical Percent Data Loss Calculation and Measurement Accuracy, T. P. Kelly, LESC-30554, December 1992. Kelly gave a solution in terms of matrix equations, and only addressed "level" channel encoding. This paper goes on to give a closed-form polynomial solution for the most common class of frame synchronizer strategies, and will also address "mark" and "space" (differential) channel encoding, and burst error environments. The paper is divided into four sections and follows a logically ordered presentation, with results developed before they are evaluated. However, most readers will derive the greatest benefit from this paper by treating the results as reference material. The result developed for differential encoding can be extended to other applications (like block codes) where the probability is needed that a block contains only a certain number of errors.
Effect of heparin bonding on catheter-induced fibrin formation and platelet activation.
Nichols, A B; Owen, J; Grossman, B A; Marcella, J J; Fleisher, L N; Lee, M M
1984-11-01
Pathologic and experimental evidence indicates that platelet activation and fibrin formation contribute to the pathogenesis of angina pectoris, coronary vasospasm and myocardial infarction. Detection of localized intravascular platelet activation and fibrin formation in vivo by selective blood sampling requires catheters that do not induce coagulation ex vivo. We studied the effect of heparin bonding of catheter surfaces on activation of the coagulation system by cardiovascular catheters. Woven Dacron, polyvinylchloride, and polyurethane catheters were tested and compared with identical catheters with heparin-bonded surfaces in 47 patients undergoing percutaneous cardiac catheterization. Platelet activation was measured by radioimmunoassay of plasma platelet factor 4 (PF4), beta-thromboglobulin (BTG), and thromboxane B2 (TXB2) in blood samples withdrawn through catheters, and fibrin formation was assessed by determination of fibrinopeptide A (FPA) levels. In blood samples collected through conventional catheters, FPA, PF4, BTG, and TXB2 levels were markedly elevated; blood sampling through heparin-bonded catheters had no significant effect on FPA, PF4, BTG, or TXB2 levels. Scanning electron microscopy disclosed extensive platelet aggregates and fibrin strands adherent to the surface of conventional catheters but not to heparin-bonded catheter surfaces. This study demonstrates that (1) collection of blood samples through cardiovascular catheters causes artifactual elevation of FPA, PF4, BTG, and TXB2 levels, and (2) heparin-bonded catheter surfaces effectively prevent catheter-induced platelet alpha-granule release and fibrin formation on catheter surfaces. Heparin-bonded catheters will facilitate investigation of the role of intravascular coagulation in coronary artery disease by eliminating catheter-induced fibrin formation and platelet activation.
Wilde, Mary H; McMahon, James M; Crean, Hugh F; Brasch, Judith
2017-09-01
To describe and explore relationships among catheter problems in long-term indwelling urinary catheter users, including excess healthcare use for treating catheter problems. Long-term urinary catheter users experience repeated problems with catheter-related urinary tract infection and blockage of the device, yet little has been reported of the patterns and relationships among relevant catheter variables. Secondary data analysis was conducted from a sample in a randomised clinical trial, using data from the entire sample of 202 persons over 12 months' participation. Descriptive statistics were used to characterise the sample over time. Zero-inflated negative binomial models were employed for logistic regressions to evaluate predictor variables of the presence/absence and frequencies of catheter-related urinary tract infection and blockage. Catheter-related urinary tract infection was marginally associated with catheter blockage. Problems reported at least once per person in the 12 months were as follows: catheter-related urinary tract infection 57%, blockage 34%, accidental dislodgment 28%, sediment 87%, leakage (bypassing) 67%, bladder spasms 59%, kinks/twists 42% and catheter pain 49%. Regression analysis demonstrated that bladder spasms were significantly related to catheter-related urinary tract infection and sediment amount, and catheter leakages were marginally significantly and positively related to catheter-related urinary tract infection. Frequencies of higher levels of sediment and catheter leakage were significantly associated with higher levels of blockage, and being female was associated with fewer blockages. Persons who need help with eating (more disabled) were also more likely to have blockages. Catheter-related urinary tract infection and blockage appear to be related and both are associated with additional healthcare expenditures. More research is needed to better understand how to prevent adverse catheter outcomes and patterns of problems in subgroups. Nurses can develop care management strategies to identify catheter blockage prior to its occurrence by tracking the amount of sediment and frequency of leakage. Bladder spasms could be an early warning of catheter-related urinary tract infection. © 2016 John Wiley & Sons Ltd.
Tamura, Tetsuo; Nakamura, Hiroshi; Sato, Say; Seki, Makoto; Nishiki, Hideto
2014-06-01
This study proposed a modified procedure, using a small balloon catheter (SB catheter, 45 ml), for reducing bladder damage in cows. Holstein cows and the following catheters were prepared: smaller balloon catheter (XSB catheter; 30 ml), SB catheter and standard balloon catheter (NB catheter; 70 ml, as the commonly used, standard size). In experiment 1, each cow was catheterized. The occurrence of catheter-associated hematuria (greater than 50 RBC/HPF) was lower in the SB catheter group (0.0%, n=7) than in the NB catheter group (71.4%, n=7; P<0.05). In experiment 2, general veterinary parameters, urine pH, body temperature and blood values in cows were not affected before or after insertion of SB catheters (n=6). The incidence of urinary tract infection (UTI) was 3.0% per catheterized day (n=22). In experiment 3, feeding profiles, daily excretion of urinary nitrogen (P<0.05) and rate from nitrogen intake in urine (P<0.01), were higher with use of the SB catheter (n=13) than with the use of the vulva urine cup (n=18), indicating that using the SB catheter can provide accurate nutritional data. From this study, we concluded that when using an SB catheter, the following results occur; reduction in bladder damage without any veterinary risks and accuracy in regard to feeding parameters, suggesting this modified procedure using an SB catheter is a useful means of daily urine collection.
Fibrinogen release and deposition on urinary catheters placed during urologic procedures
Potretzke, Aaron M.; Schreiber, Henry L.; Park, Alyssa M.; Pinkner, Jerome S.; Caparon, Michael G.; Hultgren, Scott J.; Desai, Alana
2016-01-01
Purpose Catheter-associated urinary tract infections (CAUTI) account for ~40% of all hospital-acquired infections worldwide, with more than one million cases diagnosed annually. Recent data from a CAUTI animal model has shown that inflammation induced by catheterization releases host fibrinogen that accumulates on the catheter. Further, Enterococcus faecalis catheter colonization was found to be dependent on EbpA, a fibrinogen binding adhesin. We sought to evaluate this mechanism in a human model. Materials and methods Urinary catheters were collected from human subjects hospitalized for surgical or non-surgical urologic procedures. Catheters were subjected to immunofluorescence analyses by incubating them with anti-fibrinogen antibody and then stained for fluorescence. The fluorescence intensity was compared to standard catheters. Catheters were incubated with strains of Enterococcus faecalis, Staphylococcus aureus, or Candida to assess their binding to fibrinogen-laden catheters. Results Fifty catheters were collected after various surgical and urological procedures. In vivo dwell time ranged from 1 hour to 59 days. All catheters had fibrinogen deposition and its accumulation was dependent on dwell time but not on surgical procedure or catheter material. Catheters were probed ex vivo with E. faecalis, S. aureus, and Candida albicans, which bound to catheters only in those regions where fibrinogen was deposited. Conclusions Taken together, these data show that urinary catheters act as a binding surface for accumulation of fibrinogen, which is released due to inflammation resulting from a urological procedure or from catheter placement, creating a niche that can be exploited by uropathogens to cause CAUTI. PMID:26827873
TAMURA, Tetsuo; NAKAMURA, Hiroshi; SATO, Say; SEKI, Makoto; NISHIKI, Hideto
2014-01-01
ABSTRACT This study proposed a modified procedure, using a small balloon catheter (SB catheter, 45 ml), for reducing bladder damage in cows. Holstein cows and the following catheters were prepared: smaller balloon catheter (XSB catheter; 30 ml), SB catheter and standard balloon catheter (NB catheter; 70 ml, as the commonly used, standard size). In experiment 1, each cow was catheterized. The occurrence of catheter-associated hematuria (greater than 50 RBC/HPF) was lower in the SB catheter group (0.0%, n=7) than in the NB catheter group (71.4%, n=7; P<0.05). In experiment 2, general veterinary parameters, urine pH, body temperature and blood values in cows were not affected before or after insertion of SB catheters (n=6). The incidence of urinary tract infection (UTI) was 3.0% per catheterized day (n=22). In experiment 3, feeding profiles, daily excretion of urinary nitrogen (P<0.05) and rate from nitrogen intake in urine (P<0.01), were higher with use of the SB catheter (n=13) than with the use of the vulva urine cup (n=18), indicating that using the SB catheter can provide accurate nutritional data. From this study, we concluded that when using an SB catheter, the following results occur; reduction in bladder damage without any veterinary risks and accuracy in regard to feeding parameters, suggesting this modified procedure using an SB catheter is a useful means of daily urine collection. PMID:24561376
Management of malignant pleural effusion: challenges and solutions
Penz, Erika; Watt, Kristina N; Hergott, Christopher A; Rahman, Najib M; Psallidas, Ioannis
2017-01-01
Malignant pleural effusion (MPE) is a sign of advanced cancer and is associated with significant symptom burden and mortality. To date, management has been palliative in nature with a focus on draining the pleural space, with therapies aimed at preventing recurrence or providing intermittent drainage through indwelling catheters. Given that patients with MPEs are heterogeneous with respect to their cancer type and response to systemic therapy, functional status, and pleural milieu, response to MPE therapy is also heterogeneous and difficult to predict. Furthermore, the impact of therapies on important patient outcomes has only recently been evaluated consistently in clinical trials and cohort studies. In this review, we examine patient outcomes that have been studied to date, address the question of which are most important for managing patients, and review the literature related to the expected value for money (cost-effectiveness) of indwelling pleural catheters relative to traditionally recommended approaches. PMID:28694705
Distributed parameter statics of magnetic catheters.
Tunay, Ilker
2011-01-01
We discuss how to use special Cosserat rod theory for deriving distributed-parameter static equilibrium equations of magnetic catheters. These medical devices are used for minimally-invasive diagnostic and therapeutic procedures and can be operated remotely or controlled by automated algorithms. The magnetic material can be lumped in rigid segments or distributed in flexible segments. The position vector of the cross-section centroid and quaternion representation of an orthonormal triad are selected as DOF. The strain energy for transversely isotropic, hyperelastic rods is augmented with the mechanical potential energy of the magnetic field and a penalty term to enforce the quaternion unity constraint. Numerical solution is found by 1D finite elements. Material properties of polymer tubes in extension, bending and twist are determined by mechanical and magnetic experiments. Software experiments with commercial FEM software indicate that the computational effort with the proposed method is at least one order of magnitude less than standard 3D FEM.
Abouei, Elham; Lee, Anthony M D; Pahlevaninezhad, Hamid; Hohert, Geoffrey; Cua, Michelle; Lane, Pierre; Lam, Stephen; MacAulay, Calum
2018-01-01
We present a method for the correction of motion artifacts present in two- and three-dimensional in vivo endoscopic images produced by rotary-pullback catheters. This method can correct for cardiac/breathing-based motion artifacts and catheter-based motion artifacts such as nonuniform rotational distortion (NURD). This method assumes that en face tissue imaging contains slowly varying structures that are roughly parallel to the pullback axis. The method reduces motion artifacts using a dynamic time warping solution through a cost matrix that measures similarities between adjacent frames in en face images. We optimize and demonstrate the suitability of this method using a real and simulated NURD phantom and in vivo endoscopic pulmonary optical coherence tomography and autofluorescence images. Qualitative and quantitative evaluations of the method show an enhancement of the image quality. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
Monorail Piccolino catheter: a new rapid exchange/ultralow profile coronary angioplasty system.
Mooney, M R; Douglas, J S; Mooney, J F; Madison, J D; Brandenburg, R O; Fernald, R; Van Tassel, R A
1990-06-01
The Monorail Piccolino coronary angioplasty balloon catheter (MBC) was evaluated on 118 patients at two centers. Technical success was achieved in 110 patients (93%). Time for catheter exchange and total fluoroscopy time were significantly lower for the Monorail catheter than with standard equipment (exchange time 97 vs. 170 seconds P less than .05 and fluoroscopy time 17 vs. 88 seconds P less than .001). The advantages of rapid exchange and the ability of utilize 2 Monorail balloon catheters through one 9F guiding catheter for simultaneous inflations allowed for maximal flexibility in treating patients with bifurcation lesions. The double wire approach utilizing one Monorail balloon catheter with a 7F guiding catheter was also technically successful. The Monorail Piccolino balloon catheter has unique features that allow for greater ease of operator use, rapid catheter exchange, and optimal angiographic visualization. It is felt that this catheter design provides distinct advantages over standard angioplasty equipment.
MR Coagulation: A Novel Minimally Invasive Approach to Aneurysm Repair.
Cohen, Ouri; Zhao, Ming; Nevo, Erez; Ackerman, Jerome L
2017-11-01
To demonstrate a proof of concept of magnetic resonance (MR) coagulation, in which MR imaging scanner-induced radiofrequency (RF) heating at the end of an intracatheter long wire heats and coagulates a protein solution to effect a vascular repair by embolization. MR coagulation was simulated by finite-element modeling of electromagnetic fields and specific absorption rate (SAR) in a phantom. A glass phantom consisting of a spherical cavity joined to the side of a tube was incorporated into a flow system to simulate an aneurysm and flowing blood with velocities of 0-1.7 mL/s. A double-lumen catheter containing the wire and fiberoptic temperature sensor in 1 lumen was passed through the flow system into the aneurysm, and 9 cm 3 of protein solution was injected into the aneurysm through the second lumen. The distal end of the wire was laid on the patient table as an antenna to couple RF from the body coil or was connected to a separate tuned RF pickup coil. A high RF duty-cycle turbo spin-echo pulse sequence excited the wire such that RF energy deposited at the tip of the wire coagulated the protein solution, embolizing the aneurysm. The protein coagulation temperature of 60°C was reached in the aneurysm in ∼12 seconds, yielding a coagulated mass that largely filled the aneurysm. The heating rate was controlled by adjusting pulse-sequence parameters. MR coagulation has the potential to embolize vascular defects by coagulating a protein solution delivered by catheter using MR imaging scanner-induced RF heating of an intracatheter wire. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
DeLemos, Christi; Abi-Nader, Judy; Akins, Paul T
2011-04-01
Patients in neurological critical care units often have lengthy stays that require extended vascular access and invasive hemodynamic monitoring. The traditional approach for these patients has relied heavily on central venous and pulmonary artery catheters. The aim of this study was to evaluate peripherally inserted central catheters as an alternative to central venous catheters in neurocritical care settings. Data on 35 patients who had peripherally inserted central catheters rather than central venous or pulmonary artery catheters for intravascular access and monitoring were collected from a prospective registry of neurological critical care admissions. These data were cross-referenced with information from hospital-based data registries for peripherally inserted central catheters and subarachnoid hemorrhage. Complete data were available on 33 patients with Hunt-Hess grade IV-V aneurysmal subarachnoid hemorrhage. Catheters remained in place a total of 649 days (mean, 19 days; range, 4-64 days). One patient (3%) had deep vein thrombosis in an upper extremity. In 2 patients, central venous pressure measured with a peripherally inserted catheter was higher than pressure measured concurrently with a central venous catheter. None of the 33 patients had a central catheter bloodstream infection or persistent insertion-related complications. CONCLUSIONS Use of peripherally inserted central catheters rather than central venous catheters or pulmonary artery catheters in the neurocritical care unit reduced procedural and infection risk without compromising patient management.
Uslusoy, Esin; Mete, Samiye
2008-04-01
The purpose of this study was to investigate the predisposing factors in the development of phlebitis in peripheral intravenous (IV) catheterization sites in patients treated with a variety of IV infusion solutions and drugs. Systematic observation of 568 IV sites inserted for fluid infusion and drug administration in 355 patients in the Department of General Surgery of a University Hospital in Turkey. A data collection tool was based on standards established by the Infusion Nurses Society. Patients' infusion sites were monitored every 24 h during treatment and for 48 h after discontinuation of the IV. In contrast to the usual findings in the literature, the authors found that infusion through an infusion pump and insertion of catheters in the veins around the elbow increased the risk of phlebitis. Also, the number of times infusions were started led to an increased rate of phlebitis. However, conflicting results were obtained about the relation between phlebitis, gender, and catheter size. Phlebitis causes sepsis, pain, additional diagnostic investigations, and treatments, and may lead to increased duration of hospitalization, patient's stress level, and financial burden, as well as increasing staff workload. Advanced practice nurses need to be aware of the factors that increase the likelihood of phlebitis and take appropriate measures to prevent it.
Fast vision-based catheter 3D reconstruction
NASA Astrophysics Data System (ADS)
Moradi Dalvand, Mohsen; Nahavandi, Saeid; Howe, Robert D.
2016-07-01
Continuum robots offer better maneuverability and inherent compliance and are well-suited for surgical applications as catheters, where gentle interaction with the environment is desired. However, sensing their shape and tip position is a challenge as traditional sensors can not be employed in the way they are in rigid robotic manipulators. In this paper, a high speed vision-based shape sensing algorithm for real-time 3D reconstruction of continuum robots based on the views of two arbitrary positioned cameras is presented. The algorithm is based on the closed-form analytical solution of the reconstruction of quadratic curves in 3D space from two arbitrary perspective projections. High-speed image processing algorithms are developed for the segmentation and feature extraction from the images. The proposed algorithms are experimentally validated for accuracy by measuring the tip position, length and bending and orientation angles for known circular and elliptical catheter shaped tubes. Sensitivity analysis is also carried out to evaluate the robustness of the algorithm. Experimental results demonstrate good accuracy (maximum errors of ±0.6 mm and ±0.5 deg), performance (200 Hz), and robustness (maximum absolute error of 1.74 mm, 3.64 deg for the added noises) of the proposed high speed algorithms.
Bladder Morphology Using 2 Different Catheter Designs
2017-04-10
Urologic Injuries; Urologic Diseases; Bladder Infection; Urinary Tract Infections; Mucosal Inflammation; Mucosal Infection; Bladder Injury; Catheter-Related Infections; Catheter Complications; Catheter; Infection (Indwelling Catheter); Pelvic Floor Disorders; Urinary Incontinence
A bifurcation study to guide the design of a landing gear with a combined uplock/downlock mechanism.
Knowles, James A C; Lowenberg, Mark H; Neild, Simon A; Krauskopf, Bernd
2014-12-08
This paper discusses the insights that a bifurcation analysis can provide when designing mechanisms. A model, in the form of a set of coupled steady-state equations, can be derived to describe the mechanism. Solutions to this model can be traced through the mechanism's state versus parameter space via numerical continuation, under the simultaneous variation of one or more parameters. With this approach, crucial features in the response surface, such as bifurcation points, can be identified. By numerically continuing these points in the appropriate parameter space, the resulting bifurcation diagram can be used to guide parameter selection and optimization. In this paper, we demonstrate the potential of this technique by considering an aircraft nose landing gear, with a novel locking strategy that uses a combined uplock/downlock mechanism. The landing gear is locked when in the retracted or deployed states. Transitions between these locked states and the unlocked state (where the landing gear is a mechanism) are shown to depend upon the positions of two fold point bifurcations. By performing a two-parameter continuation, the critical points are traced to identify operational boundaries. Following the variation of the fold points through parameter space, a minimum spring stiffness is identified that enables the landing gear to be locked in the retracted state. The bifurcation analysis also shows that the unlocking of a retracted landing gear should use an unlock force measure, rather than a position indicator, to de-couple the effects of the retraction and locking actuators. Overall, the study demonstrates that bifurcation analysis can enhance the understanding of the influence of design choices over a wide operating range where nonlinearity is significant.
A bifurcation study to guide the design of a landing gear with a combined uplock/downlock mechanism
Knowles, James A. C.; Lowenberg, Mark H.; Neild, Simon A.; Krauskopf, Bernd
2014-01-01
This paper discusses the insights that a bifurcation analysis can provide when designing mechanisms. A model, in the form of a set of coupled steady-state equations, can be derived to describe the mechanism. Solutions to this model can be traced through the mechanism's state versus parameter space via numerical continuation, under the simultaneous variation of one or more parameters. With this approach, crucial features in the response surface, such as bifurcation points, can be identified. By numerically continuing these points in the appropriate parameter space, the resulting bifurcation diagram can be used to guide parameter selection and optimization. In this paper, we demonstrate the potential of this technique by considering an aircraft nose landing gear, with a novel locking strategy that uses a combined uplock/downlock mechanism. The landing gear is locked when in the retracted or deployed states. Transitions between these locked states and the unlocked state (where the landing gear is a mechanism) are shown to depend upon the positions of two fold point bifurcations. By performing a two-parameter continuation, the critical points are traced to identify operational boundaries. Following the variation of the fold points through parameter space, a minimum spring stiffness is identified that enables the landing gear to be locked in the retracted state. The bifurcation analysis also shows that the unlocking of a retracted landing gear should use an unlock force measure, rather than a position indicator, to de-couple the effects of the retraction and locking actuators. Overall, the study demonstrates that bifurcation analysis can enhance the understanding of the influence of design choices over a wide operating range where nonlinearity is significant. PMID:25484601
... drainage bag. The condom catheter must be changed every day. INTERMITTENT CATHETERS You would use an intermittent catheter ... and the catheter itself with soap and water every day. Also clean the area after every bowel movement ...
Chung, P Hy; Wong, C Wy; Lai, C Kc; Siu, H K; Tsang, D Nc; Yeung, K Y; Ip, D Km; Tam, P Kh
2017-06-01
Catheter-associated urinary tract infection is a major hospital-acquired infection. This study aimed to analyse the effect of a silver alloy and hydrogel-coated catheter on the occurrence of catheter-associated urinary tract infection. This was a 1-year prospective study conducted at a single centre in Hong Kong. Adult patients with an indwelling urinary catheter for longer than 24 hours were recruited. The incidence of catheter-associated urinary tract infection in patients with a conventional latex Foley catheter without hydrogel was compared with that in patients with a silver alloy and hydrogel-coated catheter. The most recent definition of urinary tract infection was based on the latest surveillance definition of the National Healthcare Safety Network managed by Centers for Disease Control and Prevention. A total of 306 patients were recruited with a similar ratio between males and females. The mean (standard deviation) age was 81.1 (10.5) years. The total numbers of catheter-days were 4352 and 7474 in the silver-coated and conventional groups, respectively. The incidences of catheter-associated urinary tract infection per 1000 catheter-days were 6.4 and 9.4, respectively (P=0.095). There was a 31% reduction in the incidence of catheter-associated urinary tract infection per 1000 catheter-days in the silver-coated group. Escherichia coli was the most commonly involved pathogen (36.7%) of all cases. Subgroup analysis revealed that the protective effect of silver-coated catheter was more pronounced in long-term users as well as female patients with a respective 48% (P=0.027) and 42% (P=0.108) reduction in incidence of catheter-associated urinary tract infection. The mean catheterisation time per person was the longest in patients using a silver-coated catheter (17.0 days) compared with those using a conventional (10.8 days) or both types of catheter (13.6 days) [P=0.01]. Silver alloy and hydrogel-coated catheters appear to be effective in preventing catheter-associated urinary tract infection based on the latest surveillance definition. The effect is perhaps more prominent in long-term users and female patients.
Patient-specific catheter shaping for the minimally invasive closure of the left atrial appendage.
Graf, Eva C; Ott, Ilka; Praceus, Julian; Bourier, Felix; Lueth, Tim C
2018-06-01
The minimally invasive closure of the left atrial appendage is a promising alternative to anticoagulation for stroke prevention in patients suffering from atrial fibrillation. One of the challenges of this procedure is the correct positioning and the coaxial alignment of the tip of the catheter sheath to the implant landing zone. In this paper, a novel preoperative planning system is proposed that allows patient-individual shaping of catheters to facilitate the correct positioning of the catheter sheath by offering a patient-specific catheter shape. Based on preoperative three-dimensional image data, anatomical points and the planned implant position are marked interactively and a patient-specific catheter shape is calculated if the standard catheter is not considered as suitable. An approach to calculate a catheter shape with four bends by maximization of the bending radii is presented. Shaping of the catheter is supported by a bending form that is automatically generated in the planning program and can be directly manufactured by using additive manufacturing methods. The feasibility of the planning and shaping of the catheter could be successfully shown using six data sets. The patient-specific catheters were tested in comparison with standard catheters by physicians on heart models. In four of the six tested models, the participating physicians rated the patient-individual catheters better than the standard catheter. The novel approach for preoperatively planned and shaped patient-specific catheters designed for the minimally invasive closure of the left atrial appendage could be successfully implemented and a feasibility test showed promising results in anatomies that are difficult to access with the standard catheter.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Langer, Jessica M.; Cohen, Raphael M.; Berns, Jeffrey S.
Purpose: Over-the-wire exchange of tunneled dialysis catheters is the standard of care per K/DOQI guidelines for treating catheter-related bacteremia. However, Gram-positive bacteremia, specifically with staphylococcus species, may compromise over-the-wire exchange due to certain biological properties. This study addressed the effectiveness of over-the-wire exchange of staphylococcus-infected tunneled dialysis catheters compared with non-staphylococcus-infected tunneled dialysis catheters. Methods: Patients who received over-the-wire exchange of their tunneled dialysis catheter due to documented or suspected bacteremia were identified from a QA database. Study patients (n = 61) had positive cultures for Staphylococcus aureus, Staphylococcus epidermidis, or coagulase-negative staphylococcus not otherwise specified. Control patients (n =more » 35) received over-the-wire exchange of their tunneled dialysis catheter due to infection with any organism besides staphylococcus. Overall catheter survival and catheter survival among staphylococcal species were assessed. Results: There was no difference in tunneled dialysis catheter survival between study and control groups (P = 0.46). Median survival time was 96 days for study catheters and 51 days for controls; survival curves were closely superimposed. There also was no difference among the three staphylococcal groups in terms of catheter survival (P = 0.31). The median time until catheter removal was 143 days for SE, 67 days for CNS, and 88 days for SA-infected catheters. Conclusions: There is no significant difference in tunneled dialysis catheter survival between over-the-wire exchange of staphylococcus-infected tunneled dialysis catheters and those infected with other organisms.« less
Segev, G; Bankirer, T; Steinberg, D; Duvdevani, M; Shapur, N K; Friedman, M; Lavy, E
2013-01-01
Biofilm formation occurs commonly on urinary catheters. To assess the efficacy of urinary catheters coated with sustained-release varnish of chlorhexidine in decreasing catheter-associated biofilm formation in dogs. Thirty client-owned dogs. Prospective study. Thirteen dogs were catheterized with urinary catheters coated with sustained-release varnish of chlorhexidine (study group), and 13 dogs were catheterized with an untreated urinary catheter (control group). Presence and intensity of biofilm formation on the urinary catheters were assessed and compared between the groups by evaluating colony-forming units (CFU) of biofilm bacteria, and semiquantitatively, using confocal laser scanning microscopy and electron microscopy. None of the dogs experienced adverse effects associated with the presence of the urinary catheters. Median CFU count of biofilm bacteria at all portions of the urinary catheter was significantly (P < .001) lower in the study compared with the control group. The degree of biofilm formation on the urinary catheters, as evaluated by confocal laser scanning microscopy and electron microscopy, was significantly lower in the study compared with the control group. Electron microscopy examination identified crystals on some of the urinary catheters. The proportion of catheters on which crystals were observed was significantly lower on the distal part of the urinary catheter in the study group compared with the control group (16.7% versus 66.7%, respectively; P = .04). Chlorhexidine sustained-release varnish-coated urinary catheters effectively decrease urinary catheter-associated biofilm formation in dogs. Copyright © 2012 by the American College of Veterinary Internal Medicine.
Rotation of the planet mercury.
Jefferys, W H
1966-04-08
The equations of motion for the rotation of Mercury are solved for the general case by an asymptotic expansion. The findings of Liu and O'Keefe, obtained by numerical integration of a special case, that it is possible for Mercury's rotation to be locked into a 2:3 resonance with its revolution, are confirmed in detail. The general solution has further applications.
ERIC Educational Resources Information Center
Henry, Kevin Lawrence, Jr.; Dixson, Adrienne D.
2016-01-01
Charter schools have become the hegemonic "solution" for urban educational reform initiatives aimed at curtailing longstanding race-based educational inequities. The "common sense" of neoliberal charter schools as the cure to persistent inequality is best illustrated in the post-Katrina New Orleans educational reforms. This…
Numerical Sedimentation Study of Shoaling on the Ohio River near Mound City, Illinois
2015-08-01
from Lock and Dam 53 to just south of Cairo, IL. The water surface profile data on the Ohio River were collected using an Applanix POS_MV system...User Service (OPUS). The Applanix software package “POSPAC” was used to generate solution files by applying corrections from the base station data
21 CFR 876.5130 - Urological catheter and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... device that is inserted through the urethra and used to pass fluids to or from the urinary tract. This..., coude catheters, balloon retention type catheters, straight catheters, upper urinary tract catheters...
Stensballe, J; Looms, D; Nielsen, P N; Tvede, M
2005-12-01
To compare two hydrophilic-coated (SpeediCath and LoFric and one uncoated gel-lubricated catheter (InCare Advance Plus) concerning withdrawal friction force and urethral micro trauma. 49 healthy male volunteers participated in this prospective, randomised, blinded, crossover study of three different bladder catheters. The withdrawal friction force was measured, and urine analysis of blood, nitrite and leucocytes, microbiological analysis of urine cultures and subjective evaluation of the catheters were performed. 40 participants completed the study and were included in the analysis. SpeediCath exerted a significantly lower mean withdrawal friction force and work than the gel-lubricated uncoated catheter, whereas LoFric exerted a significantly higher mean friction force than both of the other catheters. The hydrophilic catheters caused less microscopic haematuria and less pain than the gel-lubricated uncoated catheter. Furthermore, 93% of the participants preferred the hydrophilic catheters. Hydrophilic-coated catheters perform better than uncoated catheters with regard to haematuria and preference. SpeediCath, but not LoFric, exerts less withdrawal friction force than InCare Advance Plus.
Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy.
Wang, Wei; Viswanathan, Akila N; Damato, Antonio L; Chen, Yue; Tse, Zion; Pan, Li; Tokuda, Junichi; Seethamraju, Ravi T; Dumoulin, Charles L; Schmidt, Ehud J; Cormack, Robert A
2015-12-01
In gynecologic cancers, magnetic resonance (MR) imaging is the modality of choice for visualizing tumors and their surroundings because of superior soft-tissue contrast. Real-time MR guidance of catheter placement in interstitial brachytherapy facilitates target coverage, and would be further improved by providing intraprocedural estimates of dosimetric coverage. A major obstacle to intraprocedural dosimetry is the time needed for catheter trajectory reconstruction. Herein the authors evaluate an active MR tracking (MRTR) system which provides rapid catheter tip localization and trajectory reconstruction. The authors assess the reliability and spatial accuracy of the MRTR system in comparison to standard catheter digitization using magnetic resonance imaging (MRI) and CT. The MRTR system includes a stylet with microcoils mounted on its shaft, which can be inserted into brachytherapy catheters and tracked by a dedicated MRTR sequence. Catheter tip localization errors of the MRTR system and their dependence on catheter locations and orientation inside the MR scanner were quantified with a water phantom. The distances between the tracked tip positions of the MRTR stylet and the predefined ground-truth tip positions were calculated for measurements performed at seven locations and with nine orientations. To evaluate catheter trajectory reconstruction, fifteen brachytherapy catheters were placed into a gel phantom with an embedded catheter fixation framework, with parallel or crossed paths. The MRTR stylet was then inserted sequentially into each catheter. During the removal of the MRTR stylet from within each catheter, a MRTR measurement was performed at 40 Hz to acquire the instantaneous stylet tip position, resulting in a series of three-dimensional (3D) positions along the catheter's trajectory. A 3D polynomial curve was fit to the tracked positions for each catheter, and equally spaced dwell points were then generated along the curve. High-resolution 3D MRI of the phantom was performed followed by catheter digitization based on the catheter's imaging artifacts. The catheter trajectory error was characterized in terms of the mean distance between corresponding dwell points in MRTR-generated catheter trajectory and MRI-based catheter digitization. The MRTR-based catheter trajectory reconstruction process was also performed on three gynecologic cancer patients, and then compared with catheter digitization based on MRI and CT. The catheter tip localization error increased as the MRTR stylet moved further off-center and as the stylet's orientation deviated from the main magnetic field direction. Fifteen catheters' trajectories were reconstructed by MRTR. Compared with MRI-based digitization, the mean 3D error of MRTR-generated trajectories was 1.5 ± 0.5 mm with an in-plane error of 0.7 ± 0.2 mm and a tip error of 1.7 ± 0.5 mm. MRTR resolved ambiguity in catheter assignment due to crossed catheter paths, which is a common problem in image-based catheter digitization. In the patient studies, the MRTR-generated catheter trajectory was consistent with digitization based on both MRI and CT. The MRTR system provides accurate catheter tip localization and trajectory reconstruction in the MR environment. Relative to the image-based methods, it improves the speed, safety, and reliability of the catheter trajectory reconstruction in interstitial brachytherapy. MRTR may enable in-procedural dosimetric evaluation of implant target coverage.
Minilaparotomy salvage of malfunctioning catheters in peritoneal dialysis.
Li, Jian-Ri; Cheng, Chi-Hung; Chiu, Kun-Yuan; Cheng, Chen-Li; Yang, Chi-Rei; Ho, Hao-Chung; Ko, Jiunn-Liang; Ou, Yen-Chuan
2013-01-01
Catheter malfunction is a common and significant complication during peritoneal dialysis (PD). We developed a minilaparotomy procedure to rescue malfunctioning catheters and to prevent recurrence of malfunction. From 2006 to 2011, 11 patients receiving PD had a malfunctioning catheter. In all patients, a 2-cm incision, 5 cm caudally to the previous peritoneal entry site was used to correct the malfunctioning catheter, with concomitant fixation of the catheter to the peritoneum. Catheter tip migration occurred in 7 patients, omental wrapping in 3, and blood clot obstruction in 1. The mean onset time to catheter malfunction was 197.5 days (range: 4 - 1270 days), and the mean operating time was 41 minutes (range: 35 - 56 minutes). There was no recurrence of catheter malfunction and no surgery-related peritonitis. Our minilaparotomy procedure is safe and feasible for the salvage of malfunctioning PD catheters.
Oshino, Satoru; Kishima, Haruhiko; Ohnishi, Yu-ichiro; Iwatsuki, Koichi; Saitoh, Youichi
2016-03-01
Catheter shearing is one of the most common complications of various neurosurgical modalities that use an intrathecal lumbar catheter. The sheared catheter fragment often can spontaneously migrate into the spinal canal; however, in some cases, the end of the fragment will remain outside the spinal canal. In this situation, the consulting neurosurgeons may try to retrieve the catheter fragment by approaching it directly through the catheter tract. This simple maneuver, however, can cause the fragment to slip into the spinal canal before it is secured, as we experienced recently in 2 cases. Because the fragment of the sheared catheter slipped while manipulating it within the catheter tract, we suggest that surgeons not approach the fragment along the tract to prevent it from migrating downward. Using the operative findings of an illustrative case, we describe how to avoid downward migration of the catheter fragment when retrieving a sheared lumbar catheter. We found that the sheared catheter of a lumbar-peritoneal shunt was slowly slipping along with the pulsatile movement of cerebrospinal fluid within the catheter tract. We successfully retrieved the fragment by approaching it from outside the catheter tract. We propose that surgeons approach the fragment from outside of the catheter tract. One should keep in mind a simple phrase, 'Do not follow the tail', when retrieving the sheared lumbar catheter fragment. Copyright © 2016 Elsevier Inc. All rights reserved.
Fecal containment in bedridden patients: economic impact of 2 commercial bowel catheter systems.
Kowal-Vem, Areta; Poulakidas, Stathis; Barnett, Barbara; Conway, Deborah; Culver, Daniel; Ferrari, Michelle; Potenza, Bruce; Koenig, Michael; Mah, John; Majewski, Mary; Morris, Linda; Powers, Jan; Stokes, Elizabeth; Tan, Michael; Salstrom, Sara-Jane; Zaletel, Cindy; Ambutas, Shirley; Casey, Kathleen; Stein, Jayne; DeSane, Mary; Berry, Kathy; Konz, Elizabeth C; Riemer, Michael R; Cullum, Malford E
2009-05-01
Fecal contamination is a major challenge in patients in acute/critical care settings that is associated with increased cost of care and supplies and with development of pressure ulcers, incontinence dermatitis, skin and soft tissue infections, and urinary tract infections. To assess the economic impact of fecal containment in bedridden patients using 2 different indwelling bowel catheters and to compare infection rates between groups. A multicenter, observational study was done at 12 US sites (7 that use catheter A, 5 that use catheter B). Patients were followed from insertion of an indwelling bowel catheter system until the patient left the acute/critical care unit or until 29 days after enrollment, whichever came first. Demographic data, frequency of bedding/dressing changes, incidence of infection, and Braden scores (risk of pressure ulcers) were recorded. The study included 146 bedridden patients (76 with catheter A, 70 with catheter B) who had similar Braden scores at enrollment. The rate of bedding/dressing changes per day differed significantly between groups (1.20 for catheter A vs 1.71 for catheter B; P = .004). According to a formula that accounted for personnel resources and laundry cycle costs, catheter A cost $13.94 less per patient per day to use than did catheter B. Catheter A was less likely than was catheter B to be removed during the observational period (P = .03). Observed infection rates were low. Catheter A may be more cost-effective than catheter B because it requires fewer unscheduled linen changes per patient day.
Wang, Xiang; Dong, Yan; Qi, Xiang-Qian; Li, Yi-Ming; Huang, Cheng-Guang; Hou, Li-Jun
2013-07-25
To assess the efficacy of antimicrobial-impregnated catheters in preventing catheter-related infections during external ventricular drainage (EVD), we performed a meta-analysis and systematic review. We systematically searched Medline, Embase, and the Cochrane Library. All randomized controlled trials (RCTs) and nonrandomized prospective studies (NPSs) related to antimicrobial-impregnated EVD catheters were included. The primary outcome was the rate of cerebrospinal fluid infection (CFI). The secondary outcomes included the rate of time-dependent CFI and catheter bacterial colonization. We further performed subgroup analysis, meta-regression analysis, and microbial spectrum analysis. Four RCTs and four NPSs were included. The overall rate of CFIs was 3.6% in the antimicrobial-impregnated catheter group and 13.7% in the standard catheter group. The pooled data demonstrated that antimicrobial-impregnated catheters were superior to standard catheters in lowering the rate of CFIs (odds ratio (OR) = 0.25, 95% confidence interval (CI) = 0.12 to 0.52, P <0.05). In survival analysis, the 20-day infection rate was significantly reduced with the use of antimicrobial-impregnated catheters (hazard ratio = 0.52, 95% CI = 0.29 to 0.95, P <0.05). Furthermore, a significantly decreased rate of catheter bacterial colonization was noticed for antimicrobial-impregnated catheters (OR = 0.37, 95% CI = 0.21 to 0.64, P <0.05). In subgroup analyses, although significant results remained for RCTs and NPSs, a subgroup difference was revealed (P <0.05). Compared with standard catheters, a significantly lower rate of CFIs was noticed for clindamycin/rifampin-impregnated catheters (OR = 0.27, 95% CI = 0.10 to 0.73, P <0.05) and for minocycline/rifampin-impregnated catheters (OR = 0.11, 95% CI = 0.06 to 0.21, P <0.05). However, no statistical significance was found when compared with silver-impregnated catheters (OR = 0.33, 95% CI = 0.07 to 1.69, P = 0.18). In microbial spectrum analysis, antimicrobial-impregnated catheters were shown to have a lower rate of Gram-positive bacterial infection, particularly the coagulase-negative Staphylococcus. In conclusion, the use of antimicrobial-impregnated EVD catheters could be beneficial for the prevention of CFI and catheter bacterial colonization. Although antibiotic-coated catheters seem to be effective, no sufficient evidence supports the efficacy of silver-impregnated catheters.
2013-01-01
To assess the efficacy of antimicrobial-impregnated catheters in preventing catheter-related infections during external ventricular drainage (EVD), we performed a meta-analysis and systematic review. We systematically searched Medline, Embase, and the Cochrane Library. All randomized controlled trials (RCTs) and nonrandomized prospective studies (NPSs) related to antimicrobial-impregnated EVD catheters were included. The primary outcome was the rate of cerebrospinal fluid infection (CFI). The secondary outcomes included the rate of time-dependent CFI and catheter bacterial colonization. We further performed subgroup analysis, meta-regression analysis, and microbial spectrum analysis. Four RCTs and four NPSs were included. The overall rate of CFIs was 3.6% in the antimicrobial-impregnated catheter group and 13.7% in the standard catheter group. The pooled data demonstrated that antimicrobial-impregnated catheters were superior to standard catheters in lowering the rate of CFIs (odds ratio (OR) = 0.25, 95% confidence interval (CI) = 0.12 to 0.52, P <0.05). In survival analysis, the 20-day infection rate was significantly reduced with the use of antimicrobial-impregnated catheters (hazard ratio = 0.52, 95% CI = 0.29 to 0.95, P <0.05). Furthermore, a significantly decreased rate of catheter bacterial colonization was noticed for antimicrobial-impregnated catheters (OR = 0.37, 95% CI = 0.21 to 0.64, P <0.05). In subgroup analyses, although significant results remained for RCTs and NPSs, a subgroup difference was revealed (P <0.05). Compared with standard catheters, a significantly lower rate of CFIs was noticed for clindamycin/rifampin-impregnated catheters (OR = 0.27, 95% CI = 0.10 to 0.73, P <0.05) and for minocycline/rifampin-impregnated catheters (OR = 0.11, 95% CI = 0.06 to 0.21, P <0.05). However, no statistical significance was found when compared with silver-impregnated catheters (OR = 0.33, 95% CI = 0.07 to 1.69, P = 0.18). In microbial spectrum analysis, antimicrobial-impregnated catheters were shown to have a lower rate of Gram-positive bacterial infection, particularly the coagulase-negative Staphylococcus. In conclusion, the use of antimicrobial-impregnated EVD catheters could be beneficial for the prevention of CFI and catheter bacterial colonization. Although antibiotic-coated catheters seem to be effective, no sufficient evidence supports the efficacy of silver-impregnated catheters. PMID:23890254
Antimicrobial-impregnated catheters for the prevention of catheter-related bloodstream infections.
Lorente, Leonardo
2016-05-04
Central venous catheters are commonly used in critically ill patients. Such catheterization may entail mechanical and infectious complications. The interest in catheter-related infection lies in the morbidity, mortality and costs that it involved. Numerous contributions have been made in the prevention of catheter-related infection and the current review focuses on the possible current role of antimicrobial impregnated catheters to reduce catheter-related bloodstream infections (CRBSI). There is evidence that the use of chlorhexidine-silver sulfadiazine (CHSS), rifampicin-minocycline, or rifampicin-miconazol impregnated catheters reduce the incidence of CRBSI and costs. In addition, there are some clinical circumstances associated with higher risk of CRBSI, such as the venous catheter access and the presence of tracheostomy. Current guidelines for the prevention of CRBSI recommended the use of a CHSS or rifampicin-minocycline impregnated catheter in patients whose catheter is expected to remain in place > 5 d and if the CRBSI rate has not decreased after implementation of a comprehensive strategy to reduce it.
Antimicrobial-impregnated catheters for the prevention of catheter-related bloodstream infections
Lorente, Leonardo
2016-01-01
Central venous catheters are commonly used in critically ill patients. Such catheterization may entail mechanical and infectious complications. The interest in catheter-related infection lies in the morbidity, mortality and costs that it involved. Numerous contributions have been made in the prevention of catheter-related infection and the current review focuses on the possible current role of antimicrobial impregnated catheters to reduce catheter-related bloodstream infections (CRBSI). There is evidence that the use of chlorhexidine-silver sulfadiazine (CHSS), rifampicin-minocycline, or rifampicin-miconazol impregnated catheters reduce the incidence of CRBSI and costs. In addition, there are some clinical circumstances associated with higher risk of CRBSI, such as the venous catheter access and the presence of tracheostomy. Current guidelines for the prevention of CRBSI recommended the use of a CHSS or rifampicin-minocycline impregnated catheter in patients whose catheter is expected to remain in place > 5 d and if the CRBSI rate has not decreased after implementation of a comprehensive strategy to reduce it. PMID:27152256
Pasalioglu, Kadriye Burcu; Kaya, Hatice
2014-07-01
Intravenous catheters have been indispensable tools of modern medicine. Although intravenous applications can be used for a multitude of purposes, these applications may cause complications, some of which have serious effects. Of these complications, the most commonly observed is phlebitis. This study was conducted to determine the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. This study determined the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. The study included a total of 103 individuals who were administered 439 catheters and satisfied the study enrollment criteria at one infectious diseases clinic in Istanbul/Turkey. Data were compiled from Patient Information Forms, Peripheral Intravenous Catheter and Therapy Information Forms, reported grades based on the Visual Infusion Phlebitis Assessment Scale, and Peripheral Intravenous Catheter Nurse Observation Forms. The data were analyzed using SPSS. Results : The mean patient age was 53.75±15.54 (standard deviation) years, and 59.2% of the study participants were men. Phlebitis was detected in 41.2% of peripheral intravenous catheters, and the rate decreased with increased catheter indwell time. Analyses showed that catheter indwell time, antibiotic usage, sex, and catheterization sites were significantly associated with development of phlebitis. The results of this study show that catheters can be used for longer periods of time when administered under optimal conditions and with appropriate surveillance.
Pasalioglu, Kadriye Burcu; Kaya, Hatice
2014-01-01
Objective: Intravenous catheters have been indispensable tools of modern medicine. Although intravenous applications can be used for a multitude of purposes, these applications may cause complications, some of which have serious effects. Of these complications, the most commonly observed is phlebitis. This study was conducted to determine the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. Methods: This study determined the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. The study included a total of 103 individuals who were administered 439 catheters and satisfied the study enrollment criteria at one infectious diseases clinic in Istanbul/Turkey. Data were compiled from Patient Information Forms, Peripheral Intravenous Catheter and Therapy Information Forms, reported grades based on the Visual Infusion Phlebitis Assessment Scale, and Peripheral Intravenous Catheter Nurse Observation Forms. The data were analyzed using SPSS. Results : The mean patient age was 53.75±15.54 (standard deviation) years, and 59.2% of the study participants were men. Phlebitis was detected in 41.2% of peripheral intravenous catheters, and the rate decreased with increased catheter indwell time. Analyses showed that catheter indwell time, antibiotic usage, sex, and catheterization sites were significantly associated with development of phlebitis. Conclusion: The results of this study show that catheters can be used for longer periods of time when administered under optimal conditions and with appropriate surveillance. PMID:25097505
Dual-comb spectroscopy of molecular electronic transitions in condensed phases
NASA Astrophysics Data System (ADS)
Cho, Byungmoon; Yoon, Tai Hyun; Cho, Minhaeng
2018-03-01
Dual-comb spectroscopy (DCS) utilizes two phase-locked optical frequency combs to allow scanless acquisition of spectra using only a single point detector. Although recent DCS measurements demonstrate rapid acquisition of absolutely calibrated spectral lines with unprecedented precision and accuracy, complex phase-locking schemes and multiple coherent averaging present significant challenges for widespread adoption of DCS. Here, we demonstrate Global Positioning System (GPS) disciplined DCS of a molecular electronic transition in solution at around 800 nm, where the absorption spectrum is recovered by using a single time-domain interferogram. We anticipate that this simplified dual-comb technique with absolute time interval measurement and ultrabroad bandwidth will allow adoption of DCS to tackle molecular dynamics investigation through its implementation in time-resolved nonlinear spectroscopic studies and coherent multidimensional spectroscopy of coupled chromophore systems.
Number and location of drainage catheter side holes: in vitro evaluation.
Ballard, D H; Alexander, J S; Weisman, J A; Orchard, M A; Williams, J T; D'Agostino, H B
2015-09-01
To evaluate the influence of number and location of catheter shaft side holes regarding drainage efficiency in an in vitro model. Three different drainage catheter models were constructed: open-ended model with no side holes (one catheter), unilateral side hole model (six catheters with one to six unilateral side holes), and bilateral side hole model (six catheters with one to six bilateral side holes). Catheters were inserted into a drainage output-measuring device with a constant-pressure reservoir of water. The volume of water evacuated by each of the catheters at 10-second intervals was measured. A total of five trials were performed for each catheter. Data were analysed using one-way analysis of variance. The open-ended catheter had a mean drainage volume comparable to the unilateral model catheters with three, four, and five side holes. Unilateral model catheters had significant drainage volume increases up to three side holes; unilateral model catheters with more than three side holes had no significant improvement in drainage volume. All bilateral model catheters had significantly higher mean drainage volumes than their unilateral counterparts. There was no significant difference between the mean drainage volume with one, two, or three pairs of bilateral side holes. Further, there was no drainage improvement by adding additional bilateral side holes. The present in vitro study suggests that beyond a critical side hole number threshold, adding more distal side holes does not improve catheter drainage efficiency. These results may be used to enhance catheter design towards improving their drainage efficiency. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Olsen, C L; Turner, D S; Iravani, M; Waxman, K; Selam, J L; Charles, M A
1995-01-01
To evaluate the roles of 1) abdominal radiography, 2) a pressure diagnostic procedure (PDP) using a standardized diluent infusion into the catheter sideport, and 3) radiocontrast imaging of the catheter lumen as procedures for diagnosing catheter malfunction in diabetic patients implanted with a programmable intraperitoneal infusion device. Sixteen type I diabetic patients implanted with Infusaid programmable intraperitoneal insulin pumps were studied. The ability of the above three procedures to assist diagnosis of catheter malfunction and distinguish between occlusion and catheter breakage was retrospectively analyzed. Glycated hemoglobin was measured to determine the clinical importance of catheter malfunctions and decreases in pump flow due to insulin aggregation in the pump chamber. Mean glycated hemoglobin levels increased significantly from 8.0 +/- 0.3 to 9.0 +/- 0.4% (P < 0.05) before and after catheter malfunction, but not during pump flow slowdowns. Mean peak pressure during PDP was 1.96 +/- 0.14 psi (P < 0.01 vs. normal) in reversibly occluded catheters and 1.86 +/- 0.35 psi (P < 0.05 vs. normal) in broken catheters, compared with 1.32 +/- 0.23 psi in normal catheters. Decay times during PDP were > 50 s for both reversibly occluded and broken catheters (P < 0.001 vs. normal of 3.6 +/- 0.82 s). Abdominal radiographs and sideport injections of contrast material were used to distinguish the types of broken catheters. Catheter breakage and occlusion are complications in implantable insulin infusion systems and result in metabolic deterioration. The presence of a sideport allows pressure data and radiographic procedures to assist in determining the cause of catheter malfunction. A diagnostic algorithm was generated to improve efficiency in investigating catheter problems.
Hashimoto, Sho; Takahashi, Akihiko; Yamada, Takeshi; Mizuguchi, Yukio; Taniguchi, Norimasa; Hata, Tetsuya; Nakajima, Shunsuke
2017-11-20
The extension support guiding catheter has been used to perform complex percutaneous coronary intervention to increase back-up support for the guiding catheter or to ensure deep intubation for device delivery. However, because of its monorail design, advancement of the stent into the distal extension tubing segment is sometimes problematic. Although this problem is considered due to simple collision of the stent, operators have observed tangling between a monorail extension catheter and coronary guidewire in some patients. To examine movement of the collar of the extension guide catheter during advancement of the guiding catheter, we set up an in vitro model in which the guiding catheter had two curves. Rotation of the extension guide catheter was examined by both fluoroscopic imaging and movement of the hub of the proximal end of the catheter. During advancement in the first curve, the collar moved toward the outer side of the curve of the guiding catheter as the operator pushed the shaft of the extension guiding catheter, which overrode the guidewire. After crossing the first curve, the collar moved again to the outer side of the second curve (the inner side of the first curve) of the mother catheter, and then, another clockwise rotation was observed in the proximal hub. Consequently, the collar and tubing portion of the extension guide catheter rotated 360° around the coronary guidewire, and the monorail extension catheter and guidewire became tangled. There is a potential risk of unintentional twisting with the guidewire during advancement into the curved guiding catheter because of its monorail design.
Ballo, Myriam K. S.; Pulgarin, César; Hopf, Nancy; Berthet, Aurélie; Kiwi, John; Moreillon, Philippe; Bizzini, Alain
2016-01-01
In this study, silver/copper (Ag/Cu)-coated catheters were investigated for their efficacy in preventing methicillin-resistant Staphylococcus aureus (MRSA) infection in vitro and in vivo. Ag and Cu were sputtered (67/33% atomic ratio) on polyurethane catheters by direct-current magnetron sputtering. In vitro, Ag/Cu-coated and uncoated catheters were immersed in phosphate-buffered saline (PBS) or rat plasma and exposed to MRSA ATCC 43300 at 104 to 108 CFU/ml. In vivo, Ag/Cu-coated and uncoated catheters were placed in the jugular vein of rats. Directly after, MRSA (107 CFU/ml) was inoculated in the tail vein. Catheters were removed 48 h later and cultured. In vitro, Ag/Cu-coated catheters preincubated in PBS and exposed to 104 to 107 CFU/ml prevented the adherence of MRSA (0 to 12% colonization) compared to uncoated catheters (50 to 100% colonization; P < 0.005) and Ag/Cu-coated catheters retained their activity (0 to 20% colonization) when preincubated in rat plasma, whereas colonization of uncoated catheters increased (83 to 100%; P < 0.005). Ag/Cu-coating protection diminished with 108 CFU/ml in both PBS and plasma (50 to 100% colonization). In vivo, Ag/Cu-coated catheters reduced the incidence of catheter infection compared to uncoated catheters (57% versus 79%, respectively; P = 0.16) and bacteremia (31% versus 68%, respectively; P < 0.05). Scanning electron microscopy of explanted catheters suggests that the suboptimal activity of Ag/Cu catheters in vivo was due to the formation of a dense fibrin sheath over their surface. Ag/Cu-coated catheters thus may be able to prevent MRSA infections. Their activity might be improved by limiting plasma protein adsorption on their surfaces. PMID:27353266
Determining the best catheter for sonohysterography.
Dessole, S; Farina, M; Capobianco, G; Nardelli, G B; Ambrosini, G; Meloni, G B
2001-09-01
To compare the characteristics of six different catheters for performing sonohysterography (SHG) to identify those that offer the best compromise between reliability, tolerability, and cost. Prospective study. University hospital. Six hundred ten women undergoing SHG. We performed SHG with six different types of catheters: Foleycath (Wembley Rubber Products, Sepang, Malaysia), Hysca Hysterosalpingography Catheter (GTA International Medical Devices S.A., La Caleta D.N., Dominican Republic), H/S Catheter Set (Ackrad Laboratories, Cranford, NJ), PBN Balloon Hystero-Salpingography Catheter (PBN Medicals, Stenloese, Denmark), ZUI-2.0 Catheter (Zinnanti Uterine Injection; BEI Medical System International, Gembloux, Belgium), and Goldstein Catheter (Cook, Spencer, IN). We assessed the reliability, the physician's ease of use, the time requested for the insertion of the catheter, the volume of contrast medium used, the tolerability for the patients, and the cost of the catheters. In 568 (93%) correctly performed procedures, no statistically significant differences were found among the catheters. The Foleycath was the most difficult for the physician to use and required significantly more time to position correctly. The Goldstein catheter was the best tolerated by the patients. The Foleycath was the cheapest whereas the PBN Balloon was the most expensive. The choice of the catheter must be targeted to achieving a good balance between tolerability for the patients, efficacy, cost, and the personal preference of the operator.
Utility and safety of Hickman catheters for venous access after bone marrow transplantation.
Kumagai, T; Sakamaki, H; Tanikawa, S; Akiyama, H; Maeda, Y; Sasaki, T; Tsuzuki, S; Takamoto, S; Takahashi, K; Onozawa, Y
1998-03-01
Hickman catheters are useful for vascular access after bone marrow transportation because they can handle large volume and allow for easy transfusions and blood drawing through wide double lumens making it easier to case for patients under sterile conditions in a clean room. However, the safety of Hickman catheters as compared to Silastic catheters in marrow transplants has never been discussed. We therefore retrospectively reviewed the complications of two catheters in 71 allogeneic bone marrow transplant recipients between September 1986 and August 1994. The complication and infection rates of Hickman catheters were 0.21 and 0.09 per 100 device-life days, and rate of temperature >38 degrees C during leukocytopenia (<1,000 white blood cells) was 0.18. These rates were not different from those of Silastic catheters suggesting that Hickman catheters are safe and acceptable in marrow transplantation. The benefits and drawbacks of Hickman catheters relevant to catheter choice were also discussed.
Margel, David; Mizrahi, Mark; Regev-Shoshani, Gili; Ko, Mary; Moshe, Maya; Ozalvo, Rachel; Shavit-Grievink, Liat; Baniel, Jack; Kedar, Daniel; Yossepowitch, Ofer; Lifshitz, David; Nadu, Andrei; Greenberg, David; Av-Gay, Yossef
2017-01-01
Catheter-Associated Hospital-Acquired Infections (HAI's) are caused by biofilm-forming bacteria. Using a novel approach, we generated anti-infective barrier on catheters by charging them with Nitric Oxide (NO), a naturally-produced gas molecule. NO is slowly released from the catheter upon contact with physiological fluids, and prevents bacterial colonization and biofilm formation onto catheter surfaces. The aim of the study was to assess the anti-infective properties of NO-charged catheters exposed to low concentration (up to 103 CFU/ml) of microbial cells in-vitro. We assessed NO-charged tracheal tubes using Pseudomonas aeruginosa, dialysis and biliary catheters using Escherichia coli, and urinary catheters using E. coli, Candida albicans or Enterococcus faecalis. Safety and tolerability of NO-charged urinary catheters were evaluated in a phase 1 clinical study in 12 patients. Six patients were catheterized with NO-charged catheters (NO-group), followed by 6 patients catheterized with regular control catheters (CT-group). Comparison of safety parameters between the study groups was performed. NO-charged tracheal, dialysis biliary and urinary catheters prevented P. aeruginosa, E. coli and C. albicans attachment and colonization onto their surfaces and eradicated corresponding planktonic microbial cells in the surrounding media after 24-48 hours, while E. faecalis colonization onto urinary catheters was reduced by 1 log compared to controls. All patients catheterized with an NO-charged urinary catheter successfully completed the study without experiencing NO-related AE's or serious AE's (SAE's). These data highlight the potential of NO-based technology as potential platform for preventing catheter-associated HAI's.
Regev-Shoshani, Gili; KO, Mary; Moshe, Maya; Ozalvo, Rachel; Shavit-Grievink, Liat; Baniel, Jack; Kedar, Daniel; Yossepowitch, Ofer; Lifshitz, David; Nadu, Andrei; Greenberg, David; Av-Gay, Yossef
2017-01-01
Background Catheter-Associated Hospital-Acquired Infections (HAI's) are caused by biofilm-forming bacteria. Using a novel approach, we generated anti-infective barrier on catheters by charging them with Nitric Oxide (NO), a naturally-produced gas molecule. NO is slowly released from the catheter upon contact with physiological fluids, and prevents bacterial colonization and biofilm formation onto catheter surfaces. Aims and methods The aim of the study was to assess the anti-infective properties of NO-charged catheters exposed to low concentration (up to 103 CFU/ml) of microbial cells in-vitro. We assessed NO-charged tracheal tubes using Pseudomonas aeruginosa, dialysis and biliary catheters using Escherichia coli, and urinary catheters using E. coli, Candida albicans or Enterococcus faecalis. Safety and tolerability of NO-charged urinary catheters were evaluated in a phase 1 clinical study in 12 patients. Six patients were catheterized with NO-charged catheters (NO-group), followed by 6 patients catheterized with regular control catheters (CT-group). Comparison of safety parameters between the study groups was performed. Results NO-charged tracheal, dialysis biliary and urinary catheters prevented P. aeruginosa, E. coli and C. albicans attachment and colonization onto their surfaces and eradicated corresponding planktonic microbial cells in the surrounding media after 24–48 hours, while E. faecalis colonization onto urinary catheters was reduced by 1 log compared to controls. All patients catheterized with an NO-charged urinary catheter successfully completed the study without experiencing NO-related AE's or serious AE's (SAE's). Conclusion These data highlight the potential of NO-based technology as potential platform for preventing catheter-associated HAI's. PMID:28410367
Risk factors and possible mechanisms of superior vena cava intravenous port malfunction.
Wu, Ching-Yang; Hu, Han-Chung; Ko, Po-Jen; Fu, Jui-Ying; Wu, Ching-Feng; Liu, Yun-Hen; Li, Hao-Jui; Kao, Tsung-Chi; Kao, Kuo-Chin; Yu, Sheng-Yueh; Chang, Chee-Jen; Hsieh, Hong-Chang
2012-05-01
To identify the risk factors leading to catheter malfunction. Reliable venous access is crucial for cancer patients. Malfunction of intravenous ports may lead to discontinuation of treatment and repeated interventions. We retrospectively reviewed the independent risk factors for catheter malfunction among patients receiving intravenous port implantations. A total of 1508 procedures were included from the calendar year 2006, and clinical data and chest plain films were analyzed. The patients were followed-up until June 30, 2010. For patients still alive, the last outpatient follow-up date was considered as the end point. For the remaining patients, the date of death or discharge against advice was considered as the end points. The risk factors for catheter malfunction were then evaluated. The intervention-free periods of the malfunction group and nonmalfunction group were 317 and 413 days, respectively. Statistical analyses showed that the Nut-Catheter Angle was the only risk factor for catheter malfunction (P = 0.001). A logistic model also confirmed that the Nut-Catheter Angle was the only risk factor for catheter malfunction (P < 0.001). Valve tip catheters were not advantageous with regard to catheter malfunction prevention as compared to open tip catheters. A smaller Nut-Catheter Angle had a greater risk for catheter malfunction. Catheter impingement caused by inadequate pocket creation and port implantation lead to compromised catheter lumen and difficulty flushing. The possibility of retained blood and medications increased thin thrombotic biofilm formation and medication precipitation. Catheter malfunctions can be avoided by using proper surgical techniques and adequate maintenance.
Mundi, Manpreet S; Edakkanambeth Varayil, Jithinraj; McMahon, Megan T; Okano, Akiko; Vallumsetla, Nishanth; Bonnes, Sara L; Andrews, James C; Hurt, Ryan T
2016-04-01
Parenteral nutrition (PN) is a life-saving therapy for patients with intestinal failure. Safe delivery of hyperosmotic solution requires a central venous catheter (CVC) with tip in the lower superior vena cava (SVC) or at the SVC-right atrium (RA) junction. To reduce cost and delay in use of CVC, new techniques such as intravascular electrocardiogram (ECG) are being used for tip confirmation in place of chest x-ray (CXR). The present study assessed for accuracy of ECG confirmation in home PN (HPN). Records for all patients consulted for HPN from December 17, 2014, to June 16, 2015, were reviewed for patient demographics, diagnosis leading to HPN initiation, and ECG and CXR confirmation. CXRs were subsequently reviewed by a radiologist to reassess location of the CVC tip and identify those that should be adjusted. Seventy-three patients were eligible, and after assessment for research authorization and postplacement CXR, 17 patients (30% male) with an age of 54 ± 14 years were reviewed. In all patients, postplacement intravascular ECG reading stated tip in the SVC. However, based on CXR, the location of the catheter tip was satisfactory (low SVC or SVC-RA junction) in 10 of 17 patients (59%). Due to the high osmolality of PN, CVC tip location is of paramount importance. After radiology review of CXR, we noted that 7 of 17 (41%) peripherally inserted central catheter lines were in an unsatisfactory position despite ECG confirmation. With current data available, intravenous ECG confirmation should not be used as the sole source of tip confirmation in patients receiving HPN. © 2016 American Society for Parenteral and Enteral Nutrition.
Continuous intraputamenal convection-enhanced delivery in adult rhesus macaques.
Fan, Xiaotong; Nelson, Brian D; Ai, Yi; Stiles, David K; Gash, Don M; Hardy, Peter A; Zhang, Zhiming
2015-12-01
Assessing the safety and feasibility of chronic delivery of compounds to the brain using convection-enhanced delivery (CED) is important for the further development of this important therapeutic technology. The objective of this study was to follow and model the distribution of a compound delivered by CED into the putamen of rhesus monkeys. The authors sequentially implanted catheters into 4 sites spanning the left and right putamen in each of 6 rhesus monkeys. The catheters were connected to implanted pumps, which were programmed to deliver a 5-mM solution of the MRI contrast agent Gd-DTPA at 0.1 μl/minute for 7 days and 0.3 μl/minute for an additional 7 days. The animals were followed for 28 days per implant cycle during which they were periodically examined with MRI. All animals survived the 4 surgeries with no deficits in behavior. Compared with acute infusion, the volume of distribution (Vd) increased 2-fold with 7 days of chronic infusion. Increasing the flow rate 3-fold over the next week increased the Vd an additional 3-fold. Following withdrawal of the compound, the half-life of Gd-DTPA in the brain was estimated as 3.1 days based on first-order pharmacokinetics. Histological assessment of the brain showed minimal tissue damage limited to the insertion site. These results demonstrate several important features in the development of a chronically implanted pump and catheter system: 1) the ability to place catheters accurately in a predetermined target; 2) the ability to deliver compounds in a chronic fashion to the putamen; and 3) the use of MRI and MR visible tracers to follow the evolution of the infusion volume over time.
2009-01-01
Introduction Spinal cord injury patients are at risk for developing unusual complications such as autonomic dysreflexia while changing suprapubic cystostomy. We report a male patient with spina bifida in whom the Foley catheter was placed in the urethra during change of suprapubic cystostomy with serious consequences. Case presentation A male patient, born in 1972 with spina bifida and paraplaegia, underwent suprapubic cystostomy in 2003 because of increasing problems with urethral catheter. The patient would come to spinal unit for change of suprapubic catheter every four to six weeks. Two days after a routine catheter change in November 2009, this patient woke up in the morning and noticed that the suprapubic catheter had come out. He went straight to Accident and Emergency. The suprapubic catheter was changed by a health professional and this patient was sent home. But the suprapubic catheter did not drain urine. This patient developed increasing degree of pain and swelling in suprapubic region. He did not pass any urine per urethra. He felt sick and came to spinal unit five hours later. About twenty ml of contrast was injected through suprapubic catheter and X-rays were taken. The suprapubic catheter was patent; the catheter was not blocked. The Foley catheter could be seen going around in a circular manner through the urinary bladder into the urethra. The contrast did not opacify urinary bladder; but proximal urethra was seen. The tip of Foley catheter was lying in proximal urethra. The balloon of Foley catheter had been inflated in urethra. When the balloon of Foley catheter was deflated, this patient developed massive bleeding per urethra. A sterile 22 French Foley catheter was inserted through suprapubic track. The catheter drained bloody urine. He was admitted to spinal unit and received intravenous fluids and meropenem. Haematuria subsided after 48 hours. The patient was discharged home a week later in a stable condition. Conclusion This case shows that serious complications can occur during change of suprapubic catheter in patients with neuropathic bladder. After inserting a new catheter, health professionals should observe spinal cord injury patients for at least thirty minutes and ensure that (1) suprapubic catheter drains clear urine; (2) patients do not develop abdominal spasm or discomfort; (3) symptoms and signs of sepsis or autonomic dysreflexia are absent. PMID:20062546
Vaidyanathan, Subramanian; Hughes, Peter L; Soni, Bakul M; Oo, Tun; Singh, Gurpreet
2009-12-22
Spinal cord injury patients are at risk for developing unusual complications such as autonomic dysreflexia while changing suprapubic cystostomy. We report a male patient with spina bifida in whom the Foley catheter was placed in the urethra during change of suprapubic cystostomy with serious consequences. A male patient, born in 1972 with spina bifida and paraplaegia, underwent suprapubic cystostomy in 2003 because of increasing problems with urethral catheter. The patient would come to spinal unit for change of suprapubic catheter every four to six weeks. Two days after a routine catheter change in November 2009, this patient woke up in the morning and noticed that the suprapubic catheter had come out. He went straight to Accident and Emergency. The suprapubic catheter was changed by a health professional and this patient was sent home. But the suprapubic catheter did not drain urine. This patient developed increasing degree of pain and swelling in suprapubic region. He did not pass any urine per urethra. He felt sick and came to spinal unit five hours later. About twenty ml of contrast was injected through suprapubic catheter and X-rays were taken. The suprapubic catheter was patent; the catheter was not blocked. The Foley catheter could be seen going around in a circular manner through the urinary bladder into the urethra. The contrast did not opacify urinary bladder; but proximal urethra was seen. The tip of Foley catheter was lying in proximal urethra. The balloon of Foley catheter had been inflated in urethra. When the balloon of Foley catheter was deflated, this patient developed massive bleeding per urethra. A sterile 22 French Foley catheter was inserted through suprapubic track. The catheter drained bloody urine. He was admitted to spinal unit and received intravenous fluids and meropenem. Haematuria subsided after 48 hours. The patient was discharged home a week later in a stable condition. This case shows that serious complications can occur during change of suprapubic catheter in patients with neuropathic bladder. After inserting a new catheter, health professionals should observe spinal cord injury patients for at least thirty minutes and ensure that (1) suprapubic catheter drains clear urine; (2) patients do not develop abdominal spasm or discomfort; (3) symptoms and signs of sepsis or autonomic dysreflexia are absent.
A recursive solution for a fading memory filter derived from Kalman filter theory
NASA Technical Reports Server (NTRS)
Statman, J. I.
1986-01-01
A simple recursive solution for a class of fading memory tracking filters is presented. A fading memory filter provides estimates of filter states based on past measurements, similar to a traditional Kalman filter. Unlike a Kalman filter, an exponentially decaying weight is applied to older measurements, discounting their effect on present state estimates. It is shown that Kalman filters and fading memory filters are closely related solutions to a general least squares estimator problem. Closed form filter transfer functions are derived for a time invariant, steady state, fading memory filter. These can be applied in loop filter implementation of the Deep Space Network (DSN) Advanced Receiver carrier phase locked loop (PLL).
Pérez-Granda, María Jesús; Guembe, María; Cruces, Raquel; Barrio, José María; Bouza, Emilio
2016-02-02
Culture of catheter hubs and skin surrounding the catheter entry site has a negative predictive value for catheter tip colonization. However, manipulation of the hub for culture requires the hubs to be swabbed, introducing potential dislodging of biofilm and subsequent migration of microorganisms. Hubs are usually closed with needleless connectors (NCs), which are replaced regularly. Our objective was to evaluate whether culture of flushed withdrawn NCs is an alternative to hub culture when investigating central venous catheter colonization. The study population comprised 49 intensive care unit patients whose central venous catheters had been in place for at least 7 days. Cultures of NCs and skin were obtained weekly. We included 82 catheters with more than 7 days' indwelling time. The catheter tip colonization rate was 18.3% (15/82). Analysis of skin and NC cultures revealed a 92.5% negative predictive value for catheter colonization. Three episodes of catheter-related bloodstream infection (C-RBSI) occurred in patients with colonized catheters. Surveillance of NC and skin cultures could help to identify patients at risk for C-RBSI.
Catheter associated urinary tract infections
2014-01-01
Urinary tract infection attributed to the use of an indwelling urinary catheter is one of the most common infections acquired by patients in health care facilities. As biofilm ultimately develops on all of these devices, the major determinant for development of bacteriuria is duration of catheterization. While the proportion of bacteriuric subjects who develop symptomatic infection is low, the high frequency of use of indwelling urinary catheters means there is a substantial burden attributable to these infections. Catheter-acquired urinary infection is the source for about 20% of episodes of health-care acquired bacteremia in acute care facilities, and over 50% in long term care facilities. The most important interventions to prevent bacteriuria and infection are to limit indwelling catheter use and, when catheter use is necessary, to discontinue the catheter as soon as clinically feasible. Infection control programs in health care facilities must implement and monitor strategies to limit catheter-acquired urinary infection, including surveillance of catheter use, appropriateness of catheter indications, and complications. Ultimately, prevention of these infections will require technical advances in catheter materials which prevent biofilm formation. PMID:25075308
Timsit, Jean-François; Mimoz, Olivier; Mourvillier, Bruno; Souweine, Bertrand; Garrouste-Orgeas, Maïté; Alfandari, Serge; Plantefeve, Gaétan; Bronchard, Régis; Troche, Gilles; Gauzit, Remy; Antona, Marion; Canet, Emmanuel; Bohe, Julien; Lepape, Alain; Vesin, Aurélien; Arrault, Xavier; Schwebel, Carole; Adrie, Christophe; Zahar, Jean-Ralph; Ruckly, Stéphane; Tournegros, Caroline; Lucet, Jean-Christophe
2012-12-15
Most vascular catheter-related infections (CRIs) occur extraluminally in patients in the intensive care unit (ICU). Chlorhexidine-impregnated and strongly adherent dressings may decrease catheter colonization and CRI rates. To determine if chlorhexidine-impregnated and strongly adherent dressings decrease catheter colonization and CRI rates. In a 2:1:1 assessor-masked randomized trial in patients with vascular catheters inserted for an expected duration of 48 hours or more in 12 French ICUs, we compared chlorhexidine dressings, highly adhesive dressings, and standard dressings from May 2010 to July 2011. Coprimary endpoints were major CRI with or without catheter-related bloodstream infection (CR-BSI) with chlorhexidine versus nonchlorhexidine dressings and catheter colonization rate with highly adhesive nonchlorhexidine versus standard nonchlorhexidine dressings. Catheter-colonization, CR-BSIs, and skin reactions were secondary endpoints. A total of 1,879 patients (4,163 catheters and 34,339 catheter-days) were evaluated. With chlorhexidine dressings, the major-CRI rate was 67% lower (0.7 per 1,000 vs. 2.1 per 1,000 catheter-days; hazard ratio [HR], 0.328; 95% confidence interval [CI], 0.174-0.619; P = 0.0006) and the CR-BSI rate 60% lower (0.5 per 1,000 vs. 1.3 per 1,000 catheter-days; HR, 0.402; 95% CI, 0.186-0.868; P = 0.02) than with nonchlorhexidine dressings; decreases were noted in catheter colonization and skin colonization rates at catheter removal. The contact dermatitis rate was 1.1% with and 0.29% without chlorhexidine. Highly adhesive dressings decreased the detachment rate to 64.3% versus 71.9% (P < 0.0001) and the number of dressings per catheter to two (one to four) versus three (one to five) (P < 0.0001) but increased skin colonization (P < 0.0001) and catheter colonization (HR, 1.650; 95% CI, 1.21-2.26; P = 0.0016) without influencing CRI or CR-BSI rates. A large randomized trial demonstrated that chlorhexidine-gel-impregnated dressings decreased the CRI rate in patients in the ICU with intravascular catheters. Highly adhesive dressings decreased dressing detachment but increased skin and catheter colonization. Clinical trial registered with www.clinicaltrials.gov (NCT 01189682).
Paravertebral block catheter breakage by electrocautery during thoracic surgery.
Saeki, Noboru; Sugimoto, Yuki; Mori, Yoko; Kato, Takahiro; Miyoshi, Hirotsugu; Nakamura, Ryuji; Koga, Tomomichi
2017-06-01
Advantages of thoracic paravertebral analgesia (TPA) include placement of the catheter closer to the surgical field; however, the catheter can become damaged during the operation. We experienced a case of intraoperative TPA catheter breakage that prompted us to perform an experiment to investigate possible causes. A 50-year-old male underwent a thoracoscopic lower lobectomy under general anesthesia with TPA via an intercostal approach. Following surgery, it was discovered that the catheter had become occluded, as well as cut and fused, so we reopened the incision and removed the residual catheter. From that experience, we performed an experiment to examine electrocautery-induced damage in normal (Portex™, Smith's Medical), radiopaque (Perifix SoftTip™, BBraun), and reinforced (Perifix FX™, BBraun) epidural catheters (n = 8 each). Chicken meat was penetrated by each catheter and then cut by electrocautery. In the normal group, breakage occurred in 8 and occlusion in 6 of the catheters, and in the radiopaque group breakage occurred in 8 and occlusion in 7. In contrast, breakage occurred in only 3 and occlusion in none in the reinforced group, with the 5 without breakage remaining connected only by the spring coil. Furthermore, in 7 of the reinforced catheters, electric arc-induced thermal damage was observed at the tip of the catheter. A TPA catheter for thoracic surgery should be inserted via the median approach, or it should be inserted after surgery to avoid catheter damage during surgery.
The Effect of Bioturbation on Relative Paleointenstiy Records
NASA Astrophysics Data System (ADS)
Egli, R.; Zhao, X.; Gilder, S. A.
2015-12-01
Bioturbation is one of the key factors affecting the acquisition of a natural remanent magnetization (NRM) in sediments featuring a top mixed layer. In this case, a rotational diffusion process controls the acquisition timing, which is described in terms of a lock-in function, and NRM intensity. In general terms, NRM acquisition by rotational diffusion is described by a Smoluchowski-Debye differential equation, which yields analytical solutions describing how an initially acquired depositional remanent magnetization (DRM) is progressively replaced by a post-depositional remanent magnetization (PDRM) [Egli and Mao, Geochem. Geophys. Geosyst. 16, 995-1016, 2015]. These solutions in turn support the calculation of lock-in functions. Results are controlled by the following parameters: (1) a rotation diffusivity constant γ = 2DrL/ω, where Dr is the rotational diffusion coefficient, L the thickness of the mixed layer, and ω the sedimentation rate, and (2) the ratio between magnetic aligning torques τm = mB and the torques τp associated with mechanical interactions between sediment particles and with the action of perturbing forces. The PDRM acquisition rate and the extent of DRM replacement is controlled by γ, while PDRM intensity is a Langevin function of τm/ τp. Associated lock-in functions range from a constant (NRM is acquired only at the sediment surface) to the classical lock-in function starting below the mixed layer, though intermediate situations where PDRM is partially acquired in the mixed layer. This model has been confirmed by redeposition experiments performed with fresh sediment containing living microorganisms. Redeposition experiments show that the intensity of bioturbation-driven PDRMs can reach ~50% of the originally acquired DRM. Our model has profound consequences for the evaluation of relative paleointensity records, where variations can be driven by changes of the depositional environment. While this knowledge is not new, we provide for the first time a key for understanding, in a quantitative manner, how the NRM acquisition efficiency is controlled by bioturbation. A combination of proxies leading to estimates of the bioturbation activity might provide a new path for improving the reliability of relative paleointensity records.
Wieczorowska-Tobis, K; Polubinska, A; Wisniewska, J; Pawlaczyk, K; Kuzlan-Pawlaczyk, M; Filas, V; Breborowicz, A; Oreopoulos, D G
2001-03-01
Peritoneal dialysis causes the functional and morphological changes in the peritoneum that result from the bioincompatibility of dialysis solutions. We present a model of chronic peritoneal dialysis in the rat that can be used for testing the biocompatibility of dialysis fluids. Methods and Results. Long-term exposure of the peritoneum to dialysis solutions can be performed in rats with implanted peritoneal catheters. Sampling of the dialysate allows the evaluation of intraperitoneal inflammation by examining cell differential and dialysate cytokine levels. Peritoneal permeability can be evaluated at designed time intervals with the peritoneal equilibration test (PET). At the end of dialysis, peritoneal histology is studied with light and electron microscopy. Such a multidirectional approach is an effective way to test biocompatibility of dialysis solutions.
Malinova, Vesna; Schlegel, Anna; Rohde, Veit; Mielke, Dorothee
2017-07-01
For the fibrinolytic therapy of intracerebral hematomas (ICH) using recombinant tissue plasminogen activator (rtPA), a catheter position in the core of the hematoma along the largest clot diameter was assumed to be optimal for an effective clot lysis. However, it never had been proven that core position indeed enhances clot lysis if compared with less optimal catheter positions. In this study, the impact of the catheter position on the effectiveness and on the time course of clot lysis was evaluated. We analyzed the catheter position using a relative error calculating the distance perpendicular to the catheter's center in relation to hematoma's diameter and evaluated the relative hematoma volume reduction (RVR). The correlation of the RVR with the catheter position was evaluated. Additionally, we tried to identify patterns of clot lysis with different catheter positions. The patient's outcome at discharge was evaluated using the Glasgow outcome score. A total of 105 patients were included in the study. The mean hematoma volume was 56 ml. The overall RVR was 62.7 %. In 69 patients, a catheter position in the core of the clot was achieved. We found no significant correlation between catheter position and hematoma RVR (linear regression, p = 0.14). Core catheter position leads to more symmetrical hematoma RVR. Faster clot lysis happens in the vicinity of the catheter openings. We found no significant difference in the patient's outcome dependent on the catheter position (linear regression, p = 0.90). The catheter position in the core of the hematoma along its largest diameter does not significantly influence the effectiveness of clot lysis after rtPA application.
Laan, Bart J; Spijkerman, Ingrid J B; Godfried, Mieke H; Pasmooij, Berend C; Maaskant, Jolanda M; Borgert, Marjon J; Opmeer, Brent C; Vos, Margreet C; Geerlings, Suzanne E
2017-01-10
Urinary and (peripheral and central) intravenous catheters are widely used in hospitalized patients. However, up to 56% of the catheters do not have an appropriate indication and some serious complications with the use of these catheters can occur. The main objective of our quality improvement project is to reduce the use of catheters without an appropriate indication by 25-50%, and to evaluate the affecting factors of our de-implementation strategy. In a multicenter, prospective interrupted time series analysis, several interventions to avoid inappropriate use of catheters will be conducted in seven hospitals in the Netherlands. Firstly, we will define a list of appropriate indications for urinary and (peripheral and central) intravenous catheters, which will restrict the use of catheters and urge catheter removal when the indication is no longer appropriate. Secondly, after the baseline measurements, the intervention will take place, which consists of a kick-off meeting, including a competitive feedback report of the baseline measurements, and education of healthcare workers and patients. Additional strategies based on the baseline data and local conditions are optional. The primary endpoint is the percentage of catheters with an inappropriate indication on the day of data collection before and after the de-implementation strategy. Secondary endpoints are catheter-related infections or other complications, catheter re-insertion rate, length of hospital (and ICU) stay and mortality. In addition, the cost-effectiveness of the de-implementation strategy will be calculated. This study aims to reduce the use of urinary and intravenous catheters with an inappropriate indication, and as a result reduce the catheter-related complications. If (cost-) effective it provides a tool for a nationwide approach to reduce catheter-related infections and other complications. Dutch trial registry: NTR6015 . Registered 9 August 2016.
Zhang, Xiaoliang; Martin, Alastair; Jordan, Caroline; Lillaney, Prasheel; Losey, Aaron; Pang, Yong; Hu, Jeffrey; Wilson, Mark; Cooke, Daniel; Hetts, Steven W
2017-04-01
It is technically challenging to design compact yet sensitive miniature catheter radio frequency (RF) coils for endovascular interventional MR imaging. In this work, a new design method for catheter RF coils is proposed based on the coaxial transmission line resonator (TLR) technique. Due to its distributed circuit, the TLR catheter coil does not need any lumped capacitors to support its resonance, which simplifies the practical design and construction and provides a straightforward technique for designing miniature catheter-mounted imaging coils that are appropriate for interventional neurovascular procedures. The outer conductor of the TLR serves as an RF shield, which prevents electromagnetic energy loss, and improves coil Q factors. It also minimizes interaction with surrounding tissues and signal losses along the catheter coil. To investigate the technique, a prototype catheter coil was built using the proposed coaxial TLR technique and evaluated with standard RF testing and measurement methods and MR imaging experiments. Numerical simulation was carried out to assess the RF electromagnetic field behavior of the proposed TLR catheter coil and the conventional lumped-element catheter coil. The proposed TLR catheter coil was successfully tuned to 64 MHz for proton imaging at 1.5 T. B 1 fields were numerically calculated, showing improved magnetic field intensity of the TLR catheter coil over the conventional lumped-element catheter coil. MR images were acquired from a dedicated vascular phantom using the TLR catheter coil and also the system body coil. The TLR catheter coil is able to provide a significant signal-to-noise ratio (SNR) increase (a factor of 200 to 300) over its imaging volume relative to the body coil. Catheter imaging RF coil design using the proposed coaxial TLR technique is feasible and advantageous in endovascular interventional MR imaging applications.
Development of Active Catheter,Active Guide Wire and Micro Sensor Systems
Haga, Y.; Mineta, T.; Totsu, K.; Makishi, W.; Esashi, M.
2001-01-01
Summary Active catheters and active guide wires which move like a snake have been developed for catheter-based minimally invasive diagnosis and therapy. Communication and control IC chips in the active catheter reduce the number of lead wires for control. The active catheter can be not only bent but also torsioned and extended. An ultra minature fiber-optic pressure sensor; a forward-looking ultrasonic probe and a magnetic position and orientation sensor have been developed for catheters and guide wires. These moving mechanisms and several sensors which are fitted near the tip of the catheter and the guide wire will provide detailed information near the tip and enable delicate and effective catheter intervention. PMID:20663389
Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy
Wang, Wei; Viswanathan, Akila N.; Damato, Antonio L.; Chen, Yue; Tse, Zion; Pan, Li; Tokuda, Junichi; Seethamraju, Ravi T.; Dumoulin, Charles L.; Schmidt, Ehud J.; Cormack, Robert A.
2015-01-01
Purpose: In gynecologic cancers, magnetic resonance (MR) imaging is the modality of choice for visualizing tumors and their surroundings because of superior soft-tissue contrast. Real-time MR guidance of catheter placement in interstitial brachytherapy facilitates target coverage, and would be further improved by providing intraprocedural estimates of dosimetric coverage. A major obstacle to intraprocedural dosimetry is the time needed for catheter trajectory reconstruction. Herein the authors evaluate an active MR tracking (MRTR) system which provides rapid catheter tip localization and trajectory reconstruction. The authors assess the reliability and spatial accuracy of the MRTR system in comparison to standard catheter digitization using magnetic resonance imaging (MRI) and CT. Methods: The MRTR system includes a stylet with microcoils mounted on its shaft, which can be inserted into brachytherapy catheters and tracked by a dedicated MRTR sequence. Catheter tip localization errors of the MRTR system and their dependence on catheter locations and orientation inside the MR scanner were quantified with a water phantom. The distances between the tracked tip positions of the MRTR stylet and the predefined ground-truth tip positions were calculated for measurements performed at seven locations and with nine orientations. To evaluate catheter trajectory reconstruction, fifteen brachytherapy catheters were placed into a gel phantom with an embedded catheter fixation framework, with parallel or crossed paths. The MRTR stylet was then inserted sequentially into each catheter. During the removal of the MRTR stylet from within each catheter, a MRTR measurement was performed at 40 Hz to acquire the instantaneous stylet tip position, resulting in a series of three-dimensional (3D) positions along the catheter’s trajectory. A 3D polynomial curve was fit to the tracked positions for each catheter, and equally spaced dwell points were then generated along the curve. High-resolution 3D MRI of the phantom was performed followed by catheter digitization based on the catheter’s imaging artifacts. The catheter trajectory error was characterized in terms of the mean distance between corresponding dwell points in MRTR-generated catheter trajectory and MRI-based catheter digitization. The MRTR-based catheter trajectory reconstruction process was also performed on three gynecologic cancer patients, and then compared with catheter digitization based on MRI and CT. Results: The catheter tip localization error increased as the MRTR stylet moved further off-center and as the stylet’s orientation deviated from the main magnetic field direction. Fifteen catheters’ trajectories were reconstructed by MRTR. Compared with MRI-based digitization, the mean 3D error of MRTR-generated trajectories was 1.5 ± 0.5 mm with an in-plane error of 0.7 ± 0.2 mm and a tip error of 1.7 ± 0.5 mm. MRTR resolved ambiguity in catheter assignment due to crossed catheter paths, which is a common problem in image-based catheter digitization. In the patient studies, the MRTR-generated catheter trajectory was consistent with digitization based on both MRI and CT. Conclusions: The MRTR system provides accurate catheter tip localization and trajectory reconstruction in the MR environment. Relative to the image-based methods, it improves the speed, safety, and reliability of the catheter trajectory reconstruction in interstitial brachytherapy. MRTR may enable in-procedural dosimetric evaluation of implant target coverage. PMID:26632065
Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Wei, E-mail: wwang21@partners.org; Viswanathan, Akila N.; Damato, Antonio L.
2015-12-15
Purpose: In gynecologic cancers, magnetic resonance (MR) imaging is the modality of choice for visualizing tumors and their surroundings because of superior soft-tissue contrast. Real-time MR guidance of catheter placement in interstitial brachytherapy facilitates target coverage, and would be further improved by providing intraprocedural estimates of dosimetric coverage. A major obstacle to intraprocedural dosimetry is the time needed for catheter trajectory reconstruction. Herein the authors evaluate an active MR tracking (MRTR) system which provides rapid catheter tip localization and trajectory reconstruction. The authors assess the reliability and spatial accuracy of the MRTR system in comparison to standard catheter digitization usingmore » magnetic resonance imaging (MRI) and CT. Methods: The MRTR system includes a stylet with microcoils mounted on its shaft, which can be inserted into brachytherapy catheters and tracked by a dedicated MRTR sequence. Catheter tip localization errors of the MRTR system and their dependence on catheter locations and orientation inside the MR scanner were quantified with a water phantom. The distances between the tracked tip positions of the MRTR stylet and the predefined ground-truth tip positions were calculated for measurements performed at seven locations and with nine orientations. To evaluate catheter trajectory reconstruction, fifteen brachytherapy catheters were placed into a gel phantom with an embedded catheter fixation framework, with parallel or crossed paths. The MRTR stylet was then inserted sequentially into each catheter. During the removal of the MRTR stylet from within each catheter, a MRTR measurement was performed at 40 Hz to acquire the instantaneous stylet tip position, resulting in a series of three-dimensional (3D) positions along the catheter’s trajectory. A 3D polynomial curve was fit to the tracked positions for each catheter, and equally spaced dwell points were then generated along the curve. High-resolution 3D MRI of the phantom was performed followed by catheter digitization based on the catheter’s imaging artifacts. The catheter trajectory error was characterized in terms of the mean distance between corresponding dwell points in MRTR-generated catheter trajectory and MRI-based catheter digitization. The MRTR-based catheter trajectory reconstruction process was also performed on three gynecologic cancer patients, and then compared with catheter digitization based on MRI and CT. Results: The catheter tip localization error increased as the MRTR stylet moved further off-center and as the stylet’s orientation deviated from the main magnetic field direction. Fifteen catheters’ trajectories were reconstructed by MRTR. Compared with MRI-based digitization, the mean 3D error of MRTR-generated trajectories was 1.5 ± 0.5 mm with an in-plane error of 0.7 ± 0.2 mm and a tip error of 1.7 ± 0.5 mm. MRTR resolved ambiguity in catheter assignment due to crossed catheter paths, which is a common problem in image-based catheter digitization. In the patient studies, the MRTR-generated catheter trajectory was consistent with digitization based on both MRI and CT. Conclusions: The MRTR system provides accurate catheter tip localization and trajectory reconstruction in the MR environment. Relative to the image-based methods, it improves the speed, safety, and reliability of the catheter trajectory reconstruction in interstitial brachytherapy. MRTR may enable in-procedural dosimetric evaluation of implant target coverage.« less
Bouman, E A C; Gramke, H F; Wetzel, N; Vanderbroeck, T H T; Bruinsma, R; Theunissen, M; Kerkkamp, H E M; Marcus, M A E
2007-01-01
Although epidural anesthesia is considered safe, several complications may occur during puncture and insertion of a catheter. Incidences of paresthesia vary between 0.2 and 56%. A prospective, open, cohort-controlled pilot study was conducted in 188 patients, ASA I-III, age 19-87 years, scheduled for elective surgery and epidural anesthesia. We evaluated a 20 G polyamide (standard) catheter and a 20 G combined polyurethane-polyamide (new) catheter. Spontaneous reactions upon catheter-insertion, paresthesia on questioning, inadvertent dural or intravascular puncture, and reasons for early catheter removal were recorded. The incidence of paresthesia reported spontaneously was 21.3% with the standard catheter and 16.7% with the new catheter. Systematically asking for paresthesia almost doubled the paraesthesia rate. Intravascular cannulation occurred in 5%. No accidental dural punctures occurred. An overall incidence of 13.3% of technical problems led to early catheter removal. The new catheter was at least equivalent to the standard regarding epidural success rate and safety : rate of paresthesia, intravascular and dural cannulation.
Guide Catheter Extension Device Is Effective in Renal Angioplasty for Severely Calcified Lesions.
Sugimoto, Takeshi; Nomura, Tetsuya; Hori, Yusuke; Yoshioka, Kenichi; Kubota, Hiroshi; Miyawaki, Daisuke; Urata, Ryota; Kikai, Masakazu; Keira, Natsuya; Tatsumi, Tetsuya
2017-05-23
BACKGROUND The GuideLiner catheter extension device is a monorail-type "Child" support catheter that facilitates coaxial alignment with the guide catheter and provides an appropriate back-up force. This device has been developed in the field of coronary intervention, and now is becoming widely applied in the field of endovascular treatment. However, there has been no report on the effectiveness of the guide catheter extension device in percutaneous transluminal renal angioplasty (PTRA). CASE REPORT We encountered a case of atherosclerotic subtotal occlusion at the ostium of the left renal artery. Due to the severely calcified orifice and weaker back-up force provided by a JR4 guide catheter, we could not pass any guidewires through the target lesion. Therefore, we introduced a guide catheter extension device, the GuideLiner catheter, through the guide catheter and achieved good guidewire maneuverability. We finally deployed 2 balloon-expandable stents and successfully performed all PTRA procedures. CONCLUSIONS The guide catheter extension device can be effective in PTRA for severely calcified subtotal occlusion.
Peritoneal Dialysis Catheter Insertion.
Crabtree, John H; Chow, Kai-Ming
2017-01-01
The success of peritoneal dialysis as renal-replacement therapy depends on a well-functioning peritoneal catheter. Knowledge of best practices in catheter insertion can minimize the risk of catheter complications that lead to peritoneal dialysis failure. The catheter placement procedure begins with preoperative assessment of the patient to determine the most appropriate catheter type, insertion site, and exit site location. Preoperative preparation of the patient is an instrumental step in facilitating the performance of the procedure, avoiding untoward events, and promoting the desired outcome. Catheter insertion methods include percutaneous needle-guidewire with or without image guidance, open surgical dissection, peritoneoscopic procedure, and surgical laparoscopy. The insertion technique used often depends on the geographic availability of material resources and local provider expertise in placing catheters. Independent of the catheter implantation approach, adherence to a number of universal details is required to ensure the best opportunity for creating a successful long-term peritoneal access. Finally, appropriate postoperative care and catheter break-in enables a smooth transition to dialysis therapy. Copyright © 2017 Elsevier Inc. All rights reserved.
Toward a reduced-wire readout system for ultrasound imaging.
Lim, Jaemyung; Arkan, Evren F; Degertekin, F Levent; Ghovanloo, Maysam
2014-01-01
We present a system-on-a-chip (SoC) for use in high-frequency capacitive micromachined ultrasonic transducer (CMUT) imaging systems. This SoC consists of trans-impedance amplifiers (TIA), delay locked loop (DLL) based clock multiplier, quadrature sampler, and pulse width modulator (PWM). The SoC down converts RF echo signal to baseband by quadrature sampling which facilitates modulation. To send data through a 1.6 m wire in the catheter which has limited bandwidth and is vulnerable to noise, the SoC creates a pseudo-digital PWM signal which can be used for back telemetry or wireless readout of the RF data. In this implementation, using a 0.35-μm std. CMOS process, the TIA and single-to-differential (STD) converter had 45 MHz bandwidth, the quadrature sampler had 10.1 dB conversion gain, and the PWM had 5-bit ENoB. Preliminary results verified front-end functionality, and the power consumption of a TIA, STD, quadrature sampler, PWM, and clock multiplier was 26 mW from a 3 V supply.
Toward a Reduced-Wire Readout System for Ultrasound Imaging
Lim, Jaemyung; Arkan, Evren F.; Degertekin, F. Levent; Ghovanloo, Maysam
2015-01-01
We present a system-on-a-chip (SoC) for use in high-frequency capacitive micromachined ultrasonic transducer (CMUT) imaging systems. This SoC consists of trans-impedance amplifiers (TIA), delay locked loop (DLL) based clock multiplier, quadrature sampler, and pulse width modulator (PWM). The SoC down converts RF echo signal to baseband by quadrature sampling which facilitates modulation. To send data through a 1.6 m wire in the catheter which has limited bandwidth and is vulnerable to noise, the SoC creates a pseudo-digital PWM signal which can be used for back telemetry or wireless readout of the RF data. In this implementation, using a 0.35-μm std. CMOS process, the TIA and single-to-differential (STD) converter had 45 MHz bandwidth, the quadrature sampler had 10.1 dB conversion gain, and the PWM had 5-bit ENoB. Preliminary results verified front-end functionality, and the power consumption of a TIA, STD, quadrature sampler, PWM, and clock multiplier was 26 mW from a 3 V supply. PMID:25571135
Percutaneous Transluminal Cerebral Angioplasty and Stenting in Acute Vertebrobasilar Ischemic Stroke
Nistri, M.; Mangiafico, S.; Cellerini, M.; Villa, G.; Mennonna, P.; Ammannati, F.; Giordano, G. P.
2002-01-01
Summary Reports of cerebral transluminal angioplasty and stenting in patients with vertebrobasilar ischemic stroke are scanty. Herein we report on the use of “monorail” coronary balloon angioplasty and stent balloon mounted catheters in two patients with acute vertebrobasilar ischemic stroke, focussing on the differences and possible advantages of the “monorail” technique in comparison with the “over-the-wire” technique. In both patients, the clinical picture was characterized by progressive brainstem symptoms followed by acute loss of consciousness related to an atherothrombotic occlusion and subocclusion of the dominant intracranial vertebral artery, respectively. In one patient, superselective thrombolytic therapy and balloon angioplasty resulted in a dissection flap at the vertebrobasilar junction. The latter was treated by successful deployment of a coronary stent. In the other patient, the subocclusive lesion was directly treated by angioplasty and stenting without thrombolytic therapy. The clinical outcome was poor for one patient (“locked in” syndrome) while the other had a complete clinical recovery. In acute atherothrombotic vertebrobasilar stroke transluminal cerebral angioplasty and stenting may be successfully performed allowing vessel recanalization. PMID:20594522
Microfabricated therapeutic actuators and release mechanisms therefor
Lee, Abraham P.; Fitch, Joseph P.; Schumann, Daniel L.; Da Silva, Luiz; Benett, William J.; Krulevitch, Peter A.
2000-01-01
Microfabricated therapeutic actuators are fabricated using a shape memory polymer (SMP), a polyurethane-based material that undergoes a phase transformation at a specified temperature (Tg). At a temperature above temperature Tg material is soft and can be easily reshaped into another configuration. As the temperature is lowered below temperature Tg the new shape is fixed and locked in as long as the material stays below temperature Tg. Upon reheating the material to a temperature above Tg, the material will return to its original shape. By the use of such SMP material, SMP microtubing can be used as a retaining/release actuator for the delivery of material, such as embolic coils, for example, through catheters into aneurysms, for example. The microtubing can be manufactured in various sizes and the phase change temperature Tg is determinate for an intended temperature target and intended use. The SMP microtubing can be positioned around or within an end of a deposit material. Various heating arrangements can be utilized with the SMP release mechanism, and the SMP microtubing can include a metallic coating for enhanced light absorption.
NASA Astrophysics Data System (ADS)
Mefleh, Fuad N.; Baker, G. Hamilton; Kwartowitz, David M.
2014-03-01
In our previous work we presented a novel image-guided surgery (IGS) system, Kit for Navigation by Image Focused Exploration (KNIFE).1,2 KNIFE has been demonstrated to be effective in guiding mock clinical procedures with the tip of an electromagnetically tracked catheter overlaid onto a pre-captured bi-plane fluoroscopic loop. Representation of the catheter in KNIFE differs greatly from what is captured by the fluoroscope, due to distortions and other properties of fluoroscopic images. When imaged by a fluoroscope, catheters can be visualized due to the inclusion of radiopaque materials (i.e. Bi, Ba, W) in the polymer blend.3 However, in KNIFE catheter location is determined using a single tracking seed located in the catheter tip that is represented as a single point overlaid on pre-captured fluoroscopic images. To bridge the gap in catheter representation between KNIFE and traditional methods we constructed a catheter with five tracking seeds positioned along the distal 70 mm of the catheter. We have currently investigated the use of four spline interpolation methods for estimation of true catheter shape and have assesed the error in their estimation of true catheter shape. In this work we present a method for the evaluation of interpolation algorithms with respect to catheter shape determination.
A novel, inexpensive, double lumen suprapubic catheter for urodynamics.
Wagner, Andrew A; Godley, Margaret L; Duffy, Patrick G; Ransley, Philip G
2004-03-01
We describe a novel, double lumen, intravesical, suprapubic catheter designed to meet the requirements of pediatric urodynamics that is easy to use and has minimal complications. A commercially available 10Fr pediatric suprapubic pigtail catheter forms the outer lumen for instilling filling media. A 16 gauge epidural catheter is inserted through the outer catheter providing an inner lumen for measuring intravesical pressures. The resultant double-lumen catheter is inserted suprapubically using a peel away needle supplied with the 10Fr catheter, with the patient under general anesthetic. The catheter has been used for 15 years in more than 700 patients with good reliability and few complications. The concentric construction of the double lumens and the rigidity of the inner intravesical pressure channel ensure there is no transmission of pressure from the filling channel to the inner lumen. The catheter has a circular cross section and a pigtail distal end which help to retain it within the bladder. There is low resistance to filling that allows adequate filling rates to be achieved by gravity rather than necessitating a pump. The catheter is easily made from readily available components and is less expensive than other double-lumen catheters suitable for suprapubic use. A reliable, double lumen catheter that fulfills criteria not found in commercially available alternatives can be inexpensively made for urodynamics.
NASA Technical Reports Server (NTRS)
Graf, Wiley E.
1991-01-01
A mixed formulation is chosen to overcome deficiencies of the standard displacement-based shell model. Element development is traced from the incremental variational principle on through to the final set of equilibrium equations. Particular attention is paid to developing specific guidelines for selecting the optimal set of strain parameters. A discussion of constraint index concepts and their predictive capability related to locking is included. Performance characteristics of the elements are assessed in a wide variety of linear and nonlinear plate/shell problems. Despite limiting the study to geometric nonlinear analysis, a substantial amount of additional insight concerning the finite element modeling of thin plate/shell structures is provided. For example, in nonlinear analysis, given the same mesh and load step size, mixed elements converge in fewer iterations than equivalent displacement-based models. It is also demonstrated that, in mixed formulations, lower order elements are preferred. Additionally, meshes used to obtain accurate linear solutions do not necessarily converge to the correct nonlinear solution. Finally, a new form of locking was identified associated with employing elements designed for biaxial bending in uniaxial bending applications.
Feasibility of virtual 3-Fr percutaneous coronary intervention using standard guiding catheters
Fujimoto, Kazuteru; Miyao, Yuji
2014-01-01
Introduction Recent studies have reported the efficacy of sheathless percutaneous coronary intervention (PCI) using hydrophilic-coated 5-Fr guiding catheters that are one to two Fr sizes smaller in diameter than the corresponding introducer sheath (virtual 3-Fr PCI). However, the limited number of shapes of hydrophilic-coated guiding catheters occasionally makes them difficult to engage and control. Aim To evaluate the efficacy and feasibility of virtual 3-Fr PCI using standard guiding catheters of various shapes. Material and methods We identified 35 consecutive patients with stable angina, who underwent virtual 3-Fr PCI using either hydrophilic-coated guiding catheters (Works™, Medikit, Japan) or standard guiding catheters (Heartrail™, Terumo, Japan). Results Thirty-five patients were identified (63% men; mean age 70 ±13 years). In 2 cases, hydrophilic-coated guiding catheters were exchanged to standard guiding catheters because of difficulty in engaging the target coronary arteries. Ultimately, standard guiding catheters were used in 20 patients (57%) and hydrophilic-coated catheters were used in 15 (43%). One of 20 patients treated with standard guiding catheters and 1 of 15 treated with hydrophilic-coated guiding catheters underwent the 4-in-3 “slender mother and child” PCI technique due to difficulty of stent deployment. There were no differences between the two groups in PCI procedural variables such as procedural time, fluoroscopy time, radiation dose, or contrast dye volume. There were no access site-related complications in this study. Conclusions These findings indicate that virtual 3-Fr PCI using standard guiding catheters is as efficient and safe as virtual 3-Fr PCI using hydrophilic-coated guiding catheters. PMID:25489315
Lim, Bernard; Venkatachalam, Kalpathi L; Jahangir, Arshad; Johnson, Susan B; Asirvatham, Samuel J
2008-08-01
Thromboembolism resulting from coagulum formation on the catheter and electrode surfaces is a serious complication with radiofrequency ablation procedures for heart rhythm disorders. Why coagulum occurs despite therapeutic heparinization is unclear. In this report, we demonstrate a novel approach to minimize coagulum formation based on the electromolecular characteristics of fibrinogen. Atomic force microscopy was used to establish that fibrinogen deposited on surfaces underwent conformational changes that resulted in spontaneous clot formation. We then immersed ablation catheters that were uncharged, negatively, or positively charged in heparinized blood for 30 minutes and noted the extent of clot formation. In separate experiments, ablation catheters were sutured to the ventricle of an excised porcine heart immersed in whole, heparinized blood and radiofrequency ablation performed for 5 minutes with and without charge delivered to the catheter tips. Electron microscopy of the catheter tips showed surface coverage of fibrin clot of the catheter to be 33.8% for negatively charged catheters, compared with 84.7% (P = 0.01) in noncharged catheters. There was no significant difference in surface coverage of fibrin clot between positively charged catheters (93.8%) and noncharged catheters (84.7%, P = ns). In contrast, the thickness of surface clot coverage for positively charged catheters was 87.5%, compared with 28.45% (P= 0.03) for noncharged catheters and 11.25% (P = 0.03) for negatively charged catheters, compared with noncharged catheters. We describe a novel method of placing negative charge on electrodes during ablation that reduced coagulum formation. This may decrease thromboembolism-related complications with radiofrequency ablation procedures.
TRAUTNER, BARBARA W.; DAROUICHE, RABIH O.; HULL, RICHARD A.; HULL, SHEILA; THORNBY, JOHN I.
2010-01-01
Purpose The capacity of a preexisting coating of Escherichia coli 83972 to reduce catheter colonization by Enterococcus faecalis 210 was investigated. Enterococcus was chosen for these trials since it is a common urinary pathogen in patients with an indwelling urinary catheter. Materials and Methods Each experiment tested 3 growth conditions. Group 1 or E. coli plus Enterococcus catheters were exposed to E. coli 83972 for 24 hours and then to Enterococcus for 30 minutes. Group 2 or E. coli alone catheters were incubated in E. coli for 24 hours and then in sterile broth for 30 minutes. Group 3 or Enterococcus alone catheters did not undergo the initial incubation with E. coli before the 30-minute incubation with Enterococcus: All catheters were then incubated in sterile human urine for 24 hours. Catheters were washed with saline and cut into 5, 1 cm. segments. Each segment was sonicated and the sonication fluid was diluted and plated. The results of each of the 5 segments were averaged and the set of experiments was repeated 7 times. Results A preexisting coating of E. coli 83972 reduced catheter colonization by E. faecalis 210 more than 10-fold. Enterococcus alone catheters had a median of 9.7 × 105 enterococci per cm., whereas E. coli plus Enterococcus catheters had a median of 0.38 × 105 enterococci per cm. (p = 0.016). Conclusions Pre-inoculating urinary catheters with E. coli 83972 significantly impedes catheter colonization by Enterococcus: These promising in vitro results prompt the clinical investigation of this particular application of bacterial interference. PMID:11743359
Jean, Guillaume; Vanel, Thierry; Bresson, Eric; Terrat, Jean-Claude; Hurot, Jean-Marc; Lorriaux, Christie; Mayor, Brice; Chazot, Charles
2009-07-01
Catheter-related adverse events (CAE) remain a major cause of mortality and morbidity. We aimed to compare the CAE prevalence and adverse events rate at 10 years interval in one centre using different devices, dressing procedures. We compared two periods, from 1994 to 1997 (period 1) and from 2004 to 2007 (period 2). We recorded all prevalent tunnelled CAE and their related adverse event rate: catheter-related bacteraemia (CRB), catheter local infection (CLI), catheter dysfunction leading to CAE exchange, thrombolytic use and spontaneous pulling up. In period 1, PermCath catheter (Quinton, N=63) and TwinCath catheter (MedComp, N=76) were used in 95 HD. BioFlex catheter (N=52) and ASPC split catheter (MedComp, N=52) were used in 72 HD in period 2. In period 1, we performed catheter dressing using povidone iodine versus alcoholic chlorexidine in period 2. Between period 1 and period 2, the CAE prevalence decreased from 15-18% to 9-6%, CRB from 1.1 to 0.23/1000 day-catheter (p<0.001), CLI from 1.1 to 0.28/1000 day-catheter (p<0.001), definitive dysfunction from 12 to 1.2% (p<0.001) and CAE pulling up from 4 to 0%. The annual urokinase consumption decreased from three to one unit per CAE. This study shows the dramatic decrease in CAE prevalence (-50%) and related-adverse events (approximately -200%) since 10 years. Switching povidone iodine to chlorexidine and using more recent catheter devices appear very efficient in decreasing catheter-related adverse events.
Low-angled peripheral intravenous catheter tip placement decreases phlebitis.
Tanabe, Hidenori; Murayama, Ryoko; Yabunaka, Koichi; Oe, Makoto; Takahashi, Toshiaki; Komiyama, Chieko; Sanada, Hiromi
2016-11-02
Peripheral intravenous catheters (PIVCs) are frequently removed due to phlebitis. We hypothesized that catheters made of polyurethane, which is more flexible than Teflon, would decrease phlebitis, and that flexibility could be estimated by measuring the catheter-tip angle. Ultrasonography in two groups of patients with different catheter types was then used to compare catheter-tip angles and phlebitis. Observational studies were carried out at a medical ward in a university hospital. Infusion therapy was administered to one group of patients in 2014 using Teflon catheters (control group, n = 200), and to another group of patients in 2015 using polyurethane catheters (investigational group, n = 207). The symptoms were assessed according to a scale developed by the Infusion Nurses Society. Long-axis ultrasonography images taken immediately before catheter removal were used to measure the angle between the central line of the catheter within 2 mm from the distal point and a tangent to the vessel wall. There were no significant differences between the two groups with respect to sex, age, and medical diagnosis. In the control and investigational groups, the rates of phlebitis were 37% (73/200) and 17% (36/207), respectively (p<0.001). The median angles of the catheter tip were 7.8° and 4.1°, respectively (p<0.001). Phlebitis occurred more frequently when the catheter-tip was placed at angle >5.8°. The frequency of phlebitis was lower in the polyurethane, in which the catheter was placed at lower angle, almost parallel to the vessel. Our results will aid in developing new catheters and in improving PIVC-securement techniques.
Chen, Shih-Hsiang; Yang, Chao-Ping; Jaing, Tang-Her; Lai, Jin-Yao; Hung, Iou-Jih
2012-04-01
Long-term central venous catheter (CVC) implantation has become more affordable in Taiwan since 1995. Surgical removal of the catheter may be the essential treatment for catheter-related bloodstream infections (CRBSI). The aim of this study was to evaluate the clinical features and microbial isolates in pediatric cancer patients with removal of CVC for CRBSI. The records of positive blood culture from hospitalized pediatric oncology patients between 1995 and 2004 were reviewed. One hundred and forty-three patients implanted with a long-term CVC were further identified. Seventeen catheters in 16 patients developed catheter-related bacteremia that needed catheter removal. The rate of catheter removal was 11.9%. The median device life was 7.7 months. Six catheters were removed within 3 months of insertion. Nine of the 17 catheters were removed from patient younger than 2 years. Eight infections occurred during severe neutropenia, and 6 patients had refractory or relapsed underlying disease. The cultural isolates were Gram-negative bacilli in 7, Gram-positive in 5, fungi in 5, and atypical mycobacterium in 1. The frequency of catheter removal for infection control was significantly higher in the first 5 years (1994-1999) compared to the last 5 years (2000-2004) (30.9 vs. 4.0%, p = 2.3 × 10(-4)). Factors such as microbiological isolates, age of infection, the status of malignancy, and neutropenia are related to catheter outcome. The reduction in patients with positive cultures needing removal of the catheters can be related to improved nursing care and more aggressive antibiotic therapy.
Ovayolu, Nimet; Torun, Seda; Ucan, Ozlem; Ozdemir, Perihan; Buyukhatipoglu, Hakan; Pehlivan, Yavuz; Geyik, Ramazan
2006-01-01
Parenteral nutrition is commonly administered to patients in intensive care units who cannot be fed gastrointestinally. Several problems might be encountered during parenteral nutrition. We designed this study to evaluate two years' data of the patients who received parenteral nutrition at the intensive care unit of the university hospital. Forty-five patients who were treated at this hospital between January 1, 2004 and December 31, 2005 were included in this study. Patient data were collected via questionnaires designed based on the information in the literature. Blood, urinary, oropharyngeal and catheter entry site cultures were obtained and analyzed on the third and seventh days of the treatment. We found the following results: 31.1% of the patients received parenteral nutrition due to renal insufficiency; ready-made amino acid/lipid solutions were used in 86.7% of the patients; 77.8% of the solutions were administered through a peripheral vein; 88.6% of total parenteral nutrition solutions given thorough the peripheral vein had higher osmolarities than 800 mOsmol/L; routine Fe and Fe binding capacity, prothrombin time, cholesterol and triglyceride level assessments were not performed before the initiation of treatment; and the culture tests most commonly revealed Staphylococcus epidermidis in the blood, Candido species in urine, Streptococcus in throat, and Staphylococcus aureus at catheter entry sites. Based on these results, we suggest that organizing a nutrition support team would be useful in order to improve the quality of the nursery and to provide close and rational management and follow-up of the patients receiving total parenteral nutrition. PMID:17225841
NASA Astrophysics Data System (ADS)
Moulas, E.; Brandon, M. T.; Podladchikov, Y.; Bennett, R. A.
2014-12-01
At present, our understanding of the locked zone at Cascadia subduction zone is based on thermal modeling and elastic modeling of horizontal GPS velocities. The thermal model by Hyndman and Wang (1995) provided a first-order assessment of where the subduction thrust might be cold enough for stick-slip behavior. The alternative approach by McCaffrey et al. (2007) is to use a Green's function that relates horizontal surface velocities, as recorded by GPS, to interseismic elastic deformation. The thermal modeling approach is limited by a lack of information about the amount of frictional heating occurring on the thrust (Molnar and England, 1990). The GPS approach is limited in that the horizontal velocity component is fairly insensitive to the structure of the locked zone. The vertical velocity component is much more useful for this purpose. We are fortunate in that vertical velocities can now be measured by GPS to a precision of about 0.2 mm/a. The dislocation model predicts that vertical velocities should range up to about 20 percent of the subduction velocity, which means maximum values of ~7 mm/a. The locked zone is generally entirely offshore at Cascadia, except for the Olympic Peninsula region, where the underlying Juan De Fuca plate has an anomalously low dip. Previous thermal and GPS modeling, as well as tide gauge data and episodic tremors indicate the locked zone there extends about 50 to 75 km onland. This situation provides an opportunity to directly study the locked zone. With that objective in mind, we have constructed a full 3D geodynamic model of the Cascadia subduction zone. At present, the model provides a full representation of the interseismic elastic deformation due to variations of slip on the subduction thrust. The model has been benchmarked against the Savage (2D) and Okada (3D) analytical solutions. This model has an important advantage over traditional dislocation modeling in that we include temperature-sensitive viscosity for the upper and lower plates, and also use realistic constitutive models to represent the locked zone. Another important advantage is that the 3D model provides a full representation of the interseismic deformation, which is important for interpreting GPS data.
Erbium-doped fiber laser passively mode locked with few-layer WSe2/MoSe2 nanosheets
NASA Astrophysics Data System (ADS)
Mao, Dong; She, Xiaoyang; Du, Bobo; Yang, Dexing; Zhang, Wending; Song, Kun; Cui, Xiaoqi; Jiang, Biqiang; Peng, Tao; Zhao, Jianlin
2016-03-01
Few-layer transition-metal dichalcogenide WSe2/MoSe2 nanosheets are fabricated by a liquid exfoliation technique using sodium deoxycholate bile salt as surfactant, and their nonlinear optical properties are investigated based on a balanced twin-detector measurement scheme. It is demonstrated that both types of nanosheets exhibit nonlinear saturable absorption properties at the wavelength of 1.55 μm. By depositing the nanosheets on side polished fiber (SPF) or mixing the nanosheets with polyvinyl alcohol (PVA) solution, SPF-WSe2 saturable absorber (SA), SPF-MoSe2 SA, PVA-WSe2 SA, and PVA-MoSe2 SA are successfully fabricated and further tested in erbium-doped fiber lasers. The SPF-based SA is capable of operating at the high pump regime without damage, and a train of 3252.65 MHz harmonically mode-locked pulses are obtained based on the SPF-WSe2 SA. Soliton mode locking operations are also achieved in the fiber laser separately with other three types of SAs, confirming that the WSe2 and MoSe2 nanosheets could act as cost-effective high-power SAs for ultrafast optics.
Francis, Tittu; Washington, Travis; Srivastava, Karan; Moutzouros, Vasilios; Makhni, Eric C; Hakeos, William
2017-11-01
Tension band wiring (TBW) and locked plating are common treatment options for Mayo IIA olecranon fractures. Clinical trials have shown excellent functional outcomes with both techniques. Although TBW implants are significantly less expensive than a locked olecranon plate, TBW often requires an additional operation for implant removal. To choose the most cost-effective treatment strategy, surgeons must understand how implant costs and return to the operating room influence the most cost-effective strategy. This cost-effective analysis study explored the optimal treatment strategies by using decision analysis tools. An expected-value decision tree was constructed to estimate costs based on the 2 implant choices. Values for critical variables, such as implant removal rate, were obtained from the literature. A Monte Carlo simulation consisting of 100,000 trials was used to incorporate variability in medical costs and implant removal rates. Sensitivity analysis and strategy tables were used to show how different variables influence the most cost-effective strategy. TBW was the most cost-effective strategy, with a cost savings of approximately $1300. TBW was also the dominant strategy by being the most cost-effective solution in 63% of the Monte Carlo trials. Sensitivity analysis identified implant costs for plate fixation and surgical costs for implant removal as the most sensitive parameters influencing the cost-effective strategy. Strategy tables showed the most cost-effective solution as 2 parameters vary simultaneously. TBW is the most cost-effective strategy in treating Mayo IIA olecranon fractures despite a higher rate of return to the operating room. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
An Intelligent Catheter System Robotic Controlled Catheter System
Negoro, M.; Tanimoto, M.; Arai, F.; Fukuda, T.; Fukasaku, K.; Takahashi, I.; Miyachi, S.
2001-01-01
Summary We have developed a novel catheter system, an intelligent catheter system, which is able to control a catheter by an externally-placed controller. This system has made from master-slave mechanism and has following three components; 1) a joy stick as a master (for operators) 2)a catheter controller as a slave (for a patient),3)a micro force sensor as a sensing device. This catheter tele-guiding system has abilities to perform intravascular procedures from the distant places. It may help to reduce the radiation exposures to the operators and also to help train young doctors. PMID:20663387
Update on voiding dysfunction managed with suprapubic catheterization
2017-01-01
As the population ages the prevalence of long-term urinary catheters, especially in the elderly, is going to increase. Urinary catheters are usually placed to manage urinary retention or incontinence that cannot be managed any other way. There is significant morbidity associated with an indwelling catheter. The commonest problems are catheter blockages, infection and bladder stones. These will occur with a similar incidence with either a suprapubic or a urethral catheter. Urethral complications such as strictures, scrotal infection and erosion are less common with suprapubic catheterization (SPC). However the benefit of having a SPC needs to be balanced against the risks involved in inserting the catheter suprapubically. Patient reported symptoms show that a SPC is more comfortable and better tolerated than a urethral catheter. However there needs to be more research into developing better catheters that reduce the frequency of urinary infections and blockages and hence catheter morbidity. PMID:28791237
Usefulness of Corsair microcatheter to cross stent struts in bifurcation lesions.
Fujimoto, Yoshihide; Iwata, Yo; Yamamoto, Masashi; Kobayashi, Yoshio
2014-01-01
Side branch compromise after stenting in bifurcation lesions is a matter of concern. It may happen that even low-profile balloon catheters do not cross stent struts after rewiring. The Corsair catheter is a hybrid catheter that has features of a microcatheter and a support catheter. The present study evaluated usefulness of the Corsair catheter to facilitate advancing a low-profile balloon catheter through stent struts in bifurcation lesions. After rewiring, low-profile balloon catheters failed to cross stent struts of 29 bifurcation lesions. The Corsair microcatheter successfully crossed stent struts in all lesions except one (97 %) where a stent was implanted to treat in-stent restenosis (stent-in-stent). Low-profile balloon catheters were able to advance into the side branch of all bifurcation lesions where the Corsair microcatheter crossed stent struts. In conclusion, the Corsair microcatheter may be utilized if low-profile balloon catheters are unable to cross stent struts in bifurcation lesions.
Johnston, Andrew J; Streater, Carmel T; Noorani, Remy; Crofts, Joanne L; Del Mundo, Aldwin B; Parker, Richard A
2012-01-01
Peripherally Inserted Central Catheters (PICCs) are increasingly being used to provide short to medium-term central venous access. The current study was designed to test the hypothesis that PICC valve technology does not influence PICC occlusion rates. Intensive care unit (ICU) patients who required a PICC were randomized to one of three types of dual lumen PICC (open ended non-valved, Groshong valve, PASV valve). PICC occlusions were recorded and managed with a protocol that used urokinase. A total of 102 patients were recruited to the study. The overall risk of occlusion per catheter was 35% (95% CI 26% to 44%). The overall rate of occlusion was 76 occlusions per 1000 catheter days (95% CI 61 to 95). Presence or type of valve did not significantly influence this rate (open-ended non-valved PICC 38% of catheters, 79 occlusions per 1000 catheter days; Groshong 38% of catheters, 60 occlusions per 1000 catheter days; PASV 27% of catheters, 99 occlusions per 1000 catheter days). The dose of urokinase required to treat PICC occlusions did not significantly differ between PICC types. Valved PICCs do not appear to influence PICC occlusion rates.
Insertion of tunneled hemodialysis catheters without fluoroscopy.
Motta Elias, Rosilene; da Silva Makida, Sonia Cristina; Abensur, Hugo; Martins Castro, Manuel Carlos; Affonso Moysés, Rosa Maria; Pereira, Benedito Jorge; Bueno de Oliveira, Rodrigo; Luders, Cláudio; Romão, João Egidio
2010-01-01
The tunneled cuffed catheter (TCC) is used as a bridge access for hemodialysis. Few prospective studies have been designed to evaluate conversion from non-tunneled to TCC without the use of fluoroscopy when performed by nephrologists. We performed an observational prospective cohort in incident patients receiving hemodialysis through a non-tunneled right jugular vein catheter. 130 procedures were performed in 122 patients (51+/-18 years). The success rate was 100%. There was a total of 26,546 catheter days. Ninety-one of the 130 catheters were removed during the study period. Life table analysis revealed primary patency rates of 92%, 82%, and 68% at 30, 60, and 120 days, respectively. Infection requiring catheter removal occurred at a frequency of 0.09 per 100 catheter days. Catheter malfunction requiring intervention occurred at a rate of 0.03 per 100 catheter days. Hypertension and duration of existing non-tunneled catheter of less than 2 weeks were independently associated with better TCC survival. The conversion from non-tunneled to TCC performed by nephrologists and without fluoroscopy may be safe by using the internal right jugular vein. The ideal time to do this procedure is within less than 2 weeks of existing non-tunneled catheter.
Echogenic Catheters and Embryo Transfer Standardization.
Urbina, Maria Teresa; Benjamin, Isaac; Medina, Randolfo; Lerner, Jorge
2015-05-01
1.To describe the standardization process and protocols of the ET method at our center. 2.To compare the performance of non-echogenic catheters with echogenic catheters during ultrasound-guided ET. Retrospective analysis of 2630 ET performed at UNIFERTES during 1997-2014, to describe standardization process and to compare the percentage of difficult ET between echogenic and non-echogenic catheters. We tested 17 non-echogenic and three echogenic catheters. Many variables were associated with the ease of ET: informed patients, waiting time for the procedure, speculum use, clinical touch, uterine contractions, cervical mucus removal, presence of blood before or after the procedure, full bladder, ultrasound guidance, uterocervical angle, mock transfer, catheter type (soft or hard, echogenic or non-echogenic, with stylet or not), catheter loading technique, duration of embryo loading (time interval since the embryos were removed from the incubator for loading until the catheter is passed to the physician), transfer procedure (time interval from the catheter was handed to the physician until the embryos were discharged in the uterus), catheter tip placement, retained embryos, bed rest after ET, operator´s proficiency. The diversity of catheters used and the percentage of difficult transfers decrease as the use of echogenic catheters increases. This process is necessary to minimize variation, ensure high quality, safe and evidence-based practice, and improve outcomes. To standardize the ET method allowed a quicker and easier transfer. The use of echogenic catheters simplified ET procedures guided by abdominal ultrasound.
Long-Term Outcomes of Single-Port Laparoscopic Placement of Peritoneal Dialysis Catheter.
Pan, Alan; Poi, Mun J; Matos, Jesus; Jiang, Jenny S; Kfoury, Elias; Echeverria, Angela; Bechara, Carlos F; Lin, Peter H
2016-07-01
Laparoscopic insertion of peritoneal dialysis (PD) catheter has become a preferred method compared to the traditional open technique for PD catheter insertion. We retrospectively report the outcome of 1-port laparoscopic placement PD catheters in our institution. A total of 263 patients with end-stage renal disease who underwent single-trocar laparoscopic PD catheter insertion during a recent 6-year period were reviewed. Laparoscopic technique involves introducing a PD catheter over a stiff guidewire into the abdominal cavity through a 10-mm laparoscopic port. Pertinent clinical variables, procedural complications, and follow-up outcome were analyzed. There were 182 men and 81 women. The mean age was 56 years. Technical success was 95.8%. Catheter occlusion was the most common early complications (<6 months) that occurred in 4 (1.5%) patients. Late complications (> 6 months) including catheter occlusion, cuff extrusion, catheter leakage, catheter migration, infection, and hernia occurred in 5 patients (1.9%), 2 patients (0.8%), 3 patients (1.1%), 3 patients (1.1%), 6 patients (2.3%), and 4 patients (1.5), respectively. Mean follow-up time was 39 ± 18 months. Catheter survival rate at 1, 2, 3, 4, and 5 years was 96%, 94%, 90%, 85%, and 82%, respectively. Laparoscopic PD catheter implantation via a single-trocar utilizing a stiff guidewire technique is feasible and safe. This method can result in low complication and high catheter survival rate. © The Author(s) 2016.
Verma, Amit; Bhani, Deepa; Tomar, Vinay; Bachhiwal, Rekha; Yadav, Shersingh
2016-06-01
Catheter Associated Urinary Tract Infections (CAUTI) are one of the most common cause of nosocomial infections. Many bacterial species show biofilm production, which provides survival benefit to them by providing protection from environmental stresses and causing decreased susceptibility to antimicrobial agents. Two most common types of catheters used in our setup are pure silicone catheter and silicone coated latex catheter. The advantage of pure silicone catheter for long term catheterization is well established. But there is still a controversy about any advantage of the silicone catheter regarding bacterial colonization rates and their biofilm production property. The aim of our study was to compare the bacterial colonization and the biofilm formation property of the colonizing bacteria in patients with indwelling pure silicone and silicone coated latex catheters. This prospective observational study was conducted in the Urology Department of our institute. Patients who needed catheterization for more than 5 days during the period July 2015 to January 2016 and had sterile precatheterisation urine were included in the study. Patients were grouped into 2 groups of 50 patients each, Group A with the pure silicone catheter and Group B with the silicone coated latex catheter. Urine culture was done on the 6(th) day of indwelling urinary catheter drainage. If growth was detected, then that bacterium was tested for biofilm production property by tissue culture plate method. Statistical analyses were performed using the Statistical Package for the Social Science Version 22 (SPSS-22). After 5 days of indwelling catheterization, the pure silicone catheter had significantly less bacterial colonization than the silicone coated latex catheter (p-value=0.03) and the biofilm forming property of colonizing bacteria was also significantly less in the pure silicone catheter as compared to the silicone coated latex catheter (p-value=0.02). There were no significant differences in the colonizing bacteria in the 2 groups. In both the groups the most common bacteria were Escherichia coli. The pure silicone catheter is advantageous over the silicone coated latex catheter in terms of incidence of bacterial colonization as well as the biofilm formation and hence in the management of CAUTI.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Damato, AL; Bhagwat, MS; Buzurovic, I
Purpose: To investigate the use of a system using EM tracking, postprocessing and error-detection algorithms for measuring brachytherapy catheter locations and for detecting errors and resolving uncertainties in treatment-planning catheter digitization. Methods: An EM tracker was used to localize 13 catheters in a clinical surface applicator (A) and 15 catheters inserted into a phantom (B). Two pairs of catheters in (B) crossed paths at a distance <2 mm, producing an undistinguishable catheter artifact in that location. EM data was post-processed for noise reduction and reformatted to provide the dwell location configuration. CT-based digitization was automatically extracted from the brachytherapy planmore » DICOM files (CT). EM dwell digitization error was characterized in terms of the average and maximum distance between corresponding EM and CT dwells per catheter. The error detection rate (detected errors / all errors) was calculated for 3 types of errors: swap of two catheter numbers; incorrect catheter number identification superior to the closest position between two catheters (mix); and catheter-tip shift. Results: The averages ± 1 standard deviation of the average and maximum registration error per catheter were 1.9±0.7 mm and 3.0±1.1 mm for (A) and 1.6±0.6 mm and 2.7±0.8 mm for (B). The error detection rate was 100% (A and B) for swap errors, mix errors, and shift >4.5 mm (A) and >5.5 mm (B); errors were detected for shifts on average >2.0 mm (A) and >2.4 mm (B). Both mix errors associated with undistinguishable catheter artifacts were detected and at least one of the involved catheters was identified. Conclusion: We demonstrated the use of an EM tracking system for localization of brachytherapy catheters, detection of digitization errors and resolution of undistinguishable catheter artifacts. Automatic digitization may be possible with a registration between the imaging and the EM frame of reference. Research funded by the Kaye Family Award 2012.« less
Schumm, K; Lam, T B L
2008-01-01
Urinary tract infection (UTI) is the most common hospital acquired infection. The major associated cause is indwelling urinary catheters. Currently there are many types of catheters available. A variety of specialized urethral catheters have been designed to reduce the risk of infection. These include antiseptic impregnated catheters and antibiotic impregnated catheters. Other issues that should be considered when choosing a catheter are ease of use, comfort and cost. The primary objective of this review was to determine the effect of type of indwelling urethral catheter on the risk of urinary tract infection in adults who undergo short-term urinary catheterization. We searched the Specialized Trials Register of the Cochrane Incontinence Group (searched September 11, 2007). We also examined the bibliographies of relevant articles and contacted catheter manufacturer representatives for trials. All randomized and quasi-randomized trials comparing types of indwelling urinary catheters for short-term catheterization in hospitalized adults. Short-term catheterization was defined as up to and including 14 days, or other temporary short-term use as defined by the trialists (for example <21 days with data time points at 7-day intervals). Data were extracted by one reviewer and independently verified by a second reviewer for both the original review and for the update. Disagreements were resolved by discussion. Data were processed as described in the Cochrane Handbook. Where data in trials were not fully reported, clarification was sought directly from the trialists (secondary sources were used to confirm results of one trial). Twenty-three trials met the inclusion criteria involving 5,236 hospitalized adults in 22 parallel group trials and 27,878 adults in one large cluster-randomized cross-over trial. The antiseptic catheters were either impregnated with silver oxide or silver alloy. Silver oxide catheters were not associated with a statistically significant reduction in bacteriuria in short-term catheterized hospitalized adults but the confidence intervals were wide (RR 0.89, 95% CI 0.68-1.15) and these catheters are no longer available. Silver alloy catheters were found to significantly reduce the incidence of asymptomatic bacteriuria (RR 0.54, 95% CI 0.43-0.67) in hospitalized adults catheterized for <1 week. At >1 week of catheterization the risk of asymptomatic bacteriuria was still reduced with the use of silver alloy catheters (RR 0.64, 95% CI 0.51-0.80). The randomized cross-over trial of silver alloy catheters versus standard catheters was excluded from the pooled results because data were not available prior to crossover. The results of this trial indicated benefit from the silver alloy catheters and included an economic analysis that indicated cost savings of between 3.3% and 35.5%. Antibiotic impregnated catheters were compared to standard catheters and found to lower the rate of asymptomatic bacteriuria in the antibiotic group at <1 week of catheterization for both minocycline and rifampicin combined (RR 0.36, 95% CI 0.18-0.73), and nitrofurazone (RR 0.52, 95% CI 0.34-0.78). However, at >1 week the results were not statistically significant. One of 56 men in the antibiotic impregnated group had a symptomatic UTI compared with 6 of 68 who had standard catheters (RR 0.20, 95% CI 0.03-1.63). Three trials compared two different types of standard catheters (defined as catheters that are not impregnated with antiseptics or antibiotics) to investigate infection. Individual trials were too small to show whether or not one type of standard catheter reduced the risk of catheter related urinary tract infection compared to another type of standard catheter. The results suggest that the use of silver alloy indwelling catheters for catheterizing hospitalized adults short-term reduces the risk of catheter acquired urinary tract infection. Further economic evaluation is required to confirm that the reduction of infection compensates for the increased cost of silver alloy catheters. Catheters impregnated with antibiotics are also beneficial in reducing bacteriuria in hospitalized adults catheterized for <1 week but the data were too few to draw conclusions about those catheterized for longer. There was not enough evidence to suggest whether or not any standard catheter was better than another in terms of reducing the risk of urinary tract infection in hospitalized adults catheterized short-term. Siliconized catheters may be less likely to cause urethral side effects in men; however, this result should be interpreted with some caution as the trials were small and the outcome definitions and specific catheters compared varied. (c) 2008 Wiley-Liss, Inc.
2006-01-01
Executive Summary Objective To review the evidence on the effectiveness of hydrophilic catheters for patients requiring intermittent catheterization. Clinical Need There are various reasons why a person would require catheterization, including surgery, urinary retention due to enlargement of the prostate, spinal cord injuries, or other physical disabilities. Urethral catheters are the most prevalent cause of nosocomial urinary tract infections, that is, those that start or occur in a hospital. A urinary tract infection (UTI) occurs when bacteria adheres to the opening of the urethra. Most infections arise from Escherichia coli, from the colon. The bacteria spread into the bladder, resulting in the development of an infection. The prevalence of UTIs varies with age and sex. There is a tenfold increase in incidence for females compared with males in childhood and throughout adult life until around 55 years, when the incidence of UTIs in men and women is equal, mostly as a consequence of prostatic problems in men. Investigators have reported that urethritis (inflammation of the urethra) is found in 2% to 19% of patients practising intermittent catheterization. The Technology Hydrophilic catheters have a polymer coating that binds o the surface of the catheter. When the polymer coating is submersed in water, it absorbs and binds the water to the catheter. The catheter surface becomes smooth and very slippery. This slippery surface remains intact upon insertion into the urethra and maintains lubrication through the length of the urethra. The hydrophilic coating is designed to reduce the friction, as the catheter is inserted with the intention of reducing the risk of urethral damage. It has been suggested that because the hydrophilic catheters do not require manual lubrication they are more sterile and thus less likely to cause infection. Most hydrophilic catheters are prepackaged in sterile water, or there is a pouch of sterile water that is broken and released into the catheter package when the catheter is ready to use. Review Strategy The Medical Advisory Secretariat searched for reports of systematic reviews of randomized controlled trials (RCTs), meta-analyses of RCTs, and RCTs. The following databases were searched: Cochrane Library International Agency for Health Technology Assessment (fourth quarter 2005), Cochrane Database of Systematic Reviews (fourth quarter 2005), Cochrane Central Register of Controlled Trials (fourth quarter 2005), MEDLINE (1966 to the third week of November 2005), MEDLINE In-Process and Other Non-indexed Citations (1966 to November 2005), and EMBASE (1980 to week 49 in 2005). Search terms were urinary catheterization, hydrophilic, intermittent, and bladder catheter. The Medical Advisory Secretariat also conducted Internet searches of Medscape (www.medscape.com) for recent reports on trials that were unpublished but presented at international conferences. In addition, the Web site Current Controlled Trials (www.controlled-trials.com) was searched for ongoing trials on urinary catheterization. Summary of Findings Five RCTs were identified that compared hydrophilic catheters to standard catheters. There was substantial variation across the studies in terms of the reason for catheterization, inclusion criteria, and type of catheter used. Two studies used reusable catheters in the control arm, while the other 3 RCTs used single-use catheters in the control arm. All 5 RCTs focused mainly on males requiring intermittent catheterization. Age varied considerably across studies. One study consisted of young males (mean age 12 years), while another included older males (mean age 71 years). The RCTs reported conflicting results regarding the effectiveness of the hydrophilic catheters compared with standard catheters in terms of rates of UTIs. All 5 RCTs had serious limitations. Two of the studies were small, and likely underpowered to detect significant differences between groups. One RCT reported 12-month follow-up data for all 123 patients even though more than one-half of the patients had dropped out of the study by 12 months. Another RCT had unequal groups at baseline: the patients in the hydrophilic group had twice the mean number of UTIs at baseline compared with the standard catheter group. The fifth RCT used catheters to treat patients with bladder cancer; therefore, the results of their study are not generalizable to the population requiring intermittent catheterization. Two studies did not find significant differences between the hydrophilic and standard catheter groups for patient satisfaction. Another RCT reported conflicting results; however, the overall opinion of the catheters was not significantly different between the treatment groups. A fourth RCT found that the hydrophilic catheters were substantially more comfortable than standard catheters. The fifth RCT did not report results for quality of life or patient satisfaction. Similar to the results for effectiveness, it is not possible to clearly establish if there is a significant difference in patient satisfaction between the patients using hydrophilic catheters and those using standard catheters. Conclusions Patients requiring intermittent catheterization use, on average, 4 to 5 intermittent catheters per day. Patients admitted to hospitals using intermittent catheters typically do not reuse catheters, owing to the potential increased risk of infection in hospital. Patients self-catheterizing at home are more likely to reuse catheters. Standard catheters cost about $1.00 to $1.50/catheter. Hydrophilic catheters cost about $2.00 to $5.00/catheter, depending on the type and whether they have antibiotics inside. All hydrophilic catheters are single-use. At this time there is insufficient evidence to indicate whether hydrophilic catheters are associated with a lower rate of UTIs and improved patient satisfaction among people requiring intermittent catheterization. PMID:23074500
Fais, Roberta; Di Luca, Mariagrazia; Rizzato, Cosmeri; Morici, Paola; Bottai, Daria; Tavanti, Arianna; Lupetti, Antonella
2017-01-01
Candida parapsilosis is a major cause of hospital-acquired infection, often related to parenteral nutrition administered via catheters and hand colonization of health care workers, and its peculiar biofilm formation ability on plastic surfaces. The mortality rate of 30% points to the pressing need for new antifungal drugs. The present study aimed at analyzing the inhibitory activity of the N-terminal lactoferrin-derived peptide, further referred to as hLF 1-11, against biofilms produced by clinical isolates of C. parapsilosis characterized for their biofilm forming ability and fluconazole susceptibility. hLF 1-11 anti-biofilm activity was assessed in terms of reduction of biofilm biomass, metabolic activity, and observation of sessile cell morphology on polystyrene microtiter plates and using an in vitro model of catheter-associated C. parapsilosis biofilm production. Moreover, fluctuation in transcription levels of genes related to cell adhesion, hyphal development and extracellular matrix production upon peptide exposure were evaluated by quantitative real time RT-PCR. The results revealed that hLF 1-11 exhibits an inhibitory effect on biofilm formation by all the C. parapsilosis isolates tested, in a dose-dependent manner, regardless of their fluconazole susceptibility. In addition, hLF 1-11 induced a statistically significant dose-dependent reduction of preformed-biofilm cellular density and metabolic activity at high peptide concentrations only. Interestingly, when assessed in a catheter lumen, hLF 1-11 was able to induce a 2-log reduction of sessile cell viability at both the peptide concentrations used in RPMI diluted in NaPB. A more pronounced anti-biofilm effect was observed (3.5-log reduction) when a 10% glucose solution was used as experimental condition on both early and preformed C. parapsilosis biofilm. Quantitative real time RT-PCR experiments confirmed that hLF 1-11 down-regulates key biofilm related genes. The overall findings suggest hLF 1-11 as a promising candidate for the prevention of C. parapsilosis biofilm formation and to treatment of mature catheter-related C. parapsilosis biofilm formation.
Fais, Roberta; Di Luca, Mariagrazia; Rizzato, Cosmeri; Morici, Paola; Bottai, Daria; Tavanti, Arianna; Lupetti, Antonella
2017-01-01
Candida parapsilosis is a major cause of hospital-acquired infection, often related to parenteral nutrition administered via catheters and hand colonization of health care workers, and its peculiar biofilm formation ability on plastic surfaces. The mortality rate of 30% points to the pressing need for new antifungal drugs. The present study aimed at analyzing the inhibitory activity of the N-terminal lactoferrin-derived peptide, further referred to as hLF 1-11, against biofilms produced by clinical isolates of C. parapsilosis characterized for their biofilm forming ability and fluconazole susceptibility. hLF 1-11 anti-biofilm activity was assessed in terms of reduction of biofilm biomass, metabolic activity, and observation of sessile cell morphology on polystyrene microtiter plates and using an in vitro model of catheter-associated C. parapsilosis biofilm production. Moreover, fluctuation in transcription levels of genes related to cell adhesion, hyphal development and extracellular matrix production upon peptide exposure were evaluated by quantitative real time RT-PCR. The results revealed that hLF 1-11 exhibits an inhibitory effect on biofilm formation by all the C. parapsilosis isolates tested, in a dose-dependent manner, regardless of their fluconazole susceptibility. In addition, hLF 1-11 induced a statistically significant dose-dependent reduction of preformed-biofilm cellular density and metabolic activity at high peptide concentrations only. Interestingly, when assessed in a catheter lumen, hLF 1-11 was able to induce a 2-log reduction of sessile cell viability at both the peptide concentrations used in RPMI diluted in NaPB. A more pronounced anti-biofilm effect was observed (3.5-log reduction) when a 10% glucose solution was used as experimental condition on both early and preformed C. parapsilosis biofilm. Quantitative real time RT-PCR experiments confirmed that hLF 1-11 down-regulates key biofilm related genes. The overall findings suggest hLF 1-11 as a promising candidate for the prevention of C. parapsilosis biofilm formation and to treatment of mature catheter-related C. parapsilosis biofilm formation. PMID:29180990
21 CFR 870.1210 - Continuous flush catheter.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...
21 CFR 870.1210 - Continuous flush catheter.
Code of Federal Regulations, 2012 CFR
2012-04-01
...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...
21 CFR 870.1210 - Continuous flush catheter.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...
Alonso-Quintela, Paula; Oulego-Erroz, Ignacio; Rodriguez-Blanco, Silvia; Muñiz-Fontan, Manoel; Lapeña-López-de Armentia, Santiago; Rodriguez-Nuñez, Antonio
2015-11-01
To compare the use of bedside ultrasound and chest radiography to verify central venous catheter tip positioning. Prospective observational study. PICU of a university hospital. Patients aged 0-14 who required a central venous catheter. None. Central venous catheter tip location was confirmed by ultrasound and chest radiography. Central venous catheters were classified as intra-atrial or extra-atrial according to their positions in relation to the cavoatrial junction. Central venous catheters located outside the vena cava were considered malpositioned. The distance between the catheter tip and the cavoatrial junction was measured. The time elapsed from image capture to interpretation was recorded. Fifty-one central venous catheters in 40 patients were analyzed. Chest radiography and ultrasound results agreed 94% of the time (κ coefficient, 0.638; p < 0.001) in determining intra-atrial and extra-atrial locations and 92% of the time in determining the diagnosis of central venous catheter malposition (κ coefficient, 0.670; p < 0.001). Chest radiography indicated a greater distance between the central venous catheter tip and the cavoatrial junction than measured by ultrasound, with a mean difference of 0.38 cm (95% CI, +0.27, +0.48 cm). Three central venous catheters were classified as extra-atrial by chest radiography but as intra-atrial by ultrasound. To locate the central venous catheter tip, ultrasound required less time than chest radiography (22.96 min [20.43 min] vs 2.23 min [1.06 min]; p < 0.001). Bedside ultrasound showed a good agreement with chest radiography in detecting central venous catheter tip location and revealing incorrect positions. Ultrasound could be a preferable method for routine verification of central venous catheter tip and can contribute to increased patient safety.
Body surface infrared thermometry in patients with central venous cateter-related infections
Silvah, José Henrique; de Lima, Cristiane Maria Mártires; de Unamuno, Maria do Rosário Del Lama; Schetino, Marco Antônio Alves; Schetino, Luana Pereira Leite; Fassini, Priscila Giácomo; Brandão, Camila Fernanda Costa e Cunha Moraes; Basile, Anibal; da Cunha, Selma Freire Carvalho; Marchini, Julio Sergio
2015-01-01
Objective To evaluate if body surface temperature close to the central venous catheter insertion area is different when patients develop catheter-related bloodstream infections. Methods Observational cross-sectional study. Using a non-contact infrared thermometer, 3 consecutive measurements of body surface temperature were collected from 39 patients with central venous catheter on the following sites: nearby the catheter insertion area or totally implantable catheter reservoir, the equivalent contralateral region (without catheter), and forehead of the same subject. Results A total of 323 observations were collected. Respectively, both in male and female patients, disregarding the occurrence of infection, the mean temperature on the catheter area minus that on the contralateral region (mean ± standard deviation: -0.3±0.6°C versus -0.2±0.5ºC; p=0.36), and the mean temperature on the catheter area minus that on the forehead (mean ± standard deviation: -0.2±0.5°C versus -0.1±0.5ºC; p=0.3) resulted in negative values. Moreover, in infected patients, higher values were obtained on the catheter area (95%CI: 36.6-37.5ºC versus 36.3-36.5ºC; p<0.01) and by temperature subtractions: catheter area minus contralateral region (95%CI: -0.17 - +0.33ºC versus -0.33 - -0.20ºC; p=0.02) and catheter area minus forehead (95%CI: -0.02 - +0.55ºC versus -0.22 - -0.10ºC; p<0.01). Conclusion Using a non-contact infrared thermometer, patients with catheter-related bloodstream infections had higher temperature values both around catheter insertion area and in the subtraction of the temperatures on the contralateral and forehead regions from those on the catheter area. PMID:26466058
Kim, Hee Jin; Lee, Tae Won; Ihm, Chun Gyoo; Kim, Myung Jae
2002-01-01
Peritoneal catheter is the lifeline for the continuous ambulatory peritoneal dialysis (CAPD) patients. Over the years, obstruction or displacement of the CAPD catheter has been one of the common complications of CAPD. Fluoroscopy-guided wire manipulation or laparoscopic surgery has been developed to manage outflow obstruction. We analyzed the catheter outcome of fluoroscopy-guided wire manipulation or laparoscopic surgery to determine the ultimate benefit of these procedures. From June 1996 to August 2000, catheter complications were manipulated in 24 patients. Eleven (46%) of these patients were initially managed by guide wire under fluoroscopic control. The remaining 13 (54%) patients were manipulated by laparoscopic surgery. A successful outcome was defined as maintained normal peritoneal catheter function at 30 days after the manipulations. Among the catheters manipulated, 18 (75%) were inserted by nephrologist and 6 (25%) by surgeons at the initiation of CAPD. Tenckhoff double-cuff peritoneal catheters were inserted to all patients. The time elapsed between catheter insertion and manipulation varied from 1 to 60 days with a mean of 11 days. The primary causes of catheter malfunction were kinking in 1 case, omental wrapping with adhesions in 9 cases, and catheter displacements in the remaining 14 cases. Thirty-day catheter function was achieved in 50% (12/24) of initial catheter manipulations, with guide wire under fluoroscopic control (46%, 5/11) and laparoscopic surgery (54%, 7/13). Overall success rate of repeated manipulation was 71% (17 of 24). The successful outcome in repairing of the malfunctioning CAPD catheters could be increased by the combination of fluoroscopy-guided wire manipulation and laparoscopic surgery. Copyright 2002 S. Karger AG, Basel
Chambers, S T; Sanders, J; Patton, W N; Ganly, P; Birch, M; Crump, J A; Spearing, R L
2005-09-01
Exit-site and tunnel infections of tunnelled central intravascular catheters are a frequent source of morbidity among neutropenic patients and may necessitate catheter removal. They require antimicrobial therapy that increases healthcare costs and is associated with adverse drug reactions. A prospective randomized clinical trial was conducted among adult patients undergoing chemotherapy in a haematology unit. Tunnelled intravascular catheters were randomized to receive the control of a standard dressing regimen as recommended by the British Committee for Standards in Haematology, or to receive the intervention of a sustained-release chlorhexidine dressing. Follow-up data were available in 112 of 114 tunnelled intravascular catheters which were randomized. Exit-site or combined exit-site/tunnel infections occurred in 23 (43%) of 54 catheters in the control group, and five (9%) of 58 catheters in the intervention group [odds ratio (OR) for intervention group compared with control group =0.13, 95% confidence intervals (CI) 0.04-0.37, P<0.001]. More tunnelled intravascular catheters were prematurely removed from the control group than the intervention group for documented infections [20/54 (37%) vs 6/58 (10%), OR=0.20, 95%CI 0.53-0.07]. However, there was no difference in the numbers of tunnelled intravascular catheters removed for all proven and suspected intravascular catheter-related infections [21/54 (39%) vs 19/58 (33%)], or in the time to removal of catheters for any reason other than death or end of treatment for underlying disease. Thus chlorhexidine dressings reduced the incidence of exit-site/tunnel infections of indwelling tunnelled intravascular catheters without prolonging catheter survival in neutropenic patients, and could be considered as part of the routine management of indwelling tunnelled intravascular catheters among neutropenic patients.
Body surface infrared thermometry in patients with central venous cateter-related infections.
Silvah, José Henrique; Lima, Cristiane Maria Mártires de; Unamuno, Maria do Rosário Del Lama de; Schetino, Marco Antônio Alves; Schetino, Luana Pereira Leite; Fassini, Priscila Giácomo; Brandão, Camila Fernanda Costa e Cunha Moraes; Basile-Filho, Anibal; Cunha, Selma Freire Carvalho da; Marchini, Julio Sergio
2015-01-01
To evaluate if body surface temperature close to the central venous catheter insertion area is different when patients develop catheter-related bloodstream infections. Observational cross-sectional study. Using a non-contact infrared thermometer, 3 consecutive measurements of body surface temperature were collected from 39 patients with central venous catheter on the following sites: nearby the catheter insertion area or totally implantable catheter reservoir, the equivalent contralateral region (without catheter), and forehead of the same subject. A total of 323 observations were collected. Respectively, both in male and female patients, disregarding the occurrence of infection, the mean temperature on the catheter area minus that on the contralateral region (mean ± standard deviation: -0.3±0.6°C versus-0.2±0.5ºC; p=0.36), and the mean temperature on the catheter area minus that on the forehead (mean ± standard deviation: -0.2±0.5°C versus-0.1±0.5ºC; p=0.3) resulted in negative values. Moreover, in infected patients, higher values were obtained on the catheter area (95%CI: 36.6-37.5ºC versus 36.3-36.5ºC; p<0.01) and by temperature subtractions: catheter area minus contralateral region (95%CI: -0.17 - +0.33ºC versus -0.33 - -0.20ºC; p=0.02) and catheter area minus forehead (95%CI: -0.02 - +0.55ºC versus-0.22 - -0.10ºC; p<0.01). Using a non-contact infrared thermometer, patients with catheter-related bloodstream infections had higher temperature values both around catheter insertion area and in the subtraction of the temperatures on the contralateral and forehead regions from those on the catheter area.
NASA Astrophysics Data System (ADS)
Sun, Qiming; Melnikov, Alexander; Mandelis, Andreas; Pagliaro, Robert H.
2018-01-01
InGaAs-camera based heterodyne lock-in carrierography (HeLIC) is developed for surface recombination velocity (SRV) imaging characterization of bare (oxide-free) hydrogen passivated Si wafer surfaces. Samples prepared using four different hydrofluoric special-solution etching conditions were tested, and a quantitative assessment of their surface quality vs. queue-time after the hydrogen passivation process was made. The data acquisition time for an SRV image was about 3 min. A "round-trip" frequency-scan mode was introduced to minimize the effects of signal transients on data self-consistency. Simultaneous best fitting of HeLIC amplitude-frequency dependencies at various queue-times was used to guarantee the reliability of resolving surface and bulk carrier recombination/transport properties. The dynamic range of the measured SRV values was established from 0.1 to 100 m/s.
SKIRT: Hybrid parallelization of radiative transfer simulations
NASA Astrophysics Data System (ADS)
Verstocken, S.; Van De Putte, D.; Camps, P.; Baes, M.
2017-07-01
We describe the design, implementation and performance of the new hybrid parallelization scheme in our Monte Carlo radiative transfer code SKIRT, which has been used extensively for modelling the continuum radiation of dusty astrophysical systems including late-type galaxies and dusty tori. The hybrid scheme combines distributed memory parallelization, using the standard Message Passing Interface (MPI) to communicate between processes, and shared memory parallelization, providing multiple execution threads within each process to avoid duplication of data structures. The synchronization between multiple threads is accomplished through atomic operations without high-level locking (also called lock-free programming). This improves the scaling behaviour of the code and substantially simplifies the implementation of the hybrid scheme. The result is an extremely flexible solution that adjusts to the number of available nodes, processors and memory, and consequently performs well on a wide variety of computing architectures.
A novel four-wire-driven robotic catheter for radio-frequency ablation treatment.
Yoshimitsu, Kitaro; Kato, Takahisa; Song, Sang-Eun; Hata, Nobuhiko
2014-09-01
Robotic catheters have been proposed to increase the efficacy and safety of the radio-frequency ablation treatment. The robotized motion of current robotic catheters mimics the motion of manual ones-namely, deflection in one direction and rotation around the catheter. With the expectation that the higher dexterity may achieve further efficacy and safety of the robotically driven treatment, we prototyped a four-wire-driven robotic catheter with the ability to deflect in two- degree-of-freedom motions in addition to rotation. A novel quad-directional structure with two wires was designed and developed to attain yaw and pitch motion in the robotic catheter. We performed a mechanical evaluation of the bendability and maneuverability of the robotic catheter and compared it with current manual catheters. We found that the four-wire-driven robotic catheter can achieve a pitching angle of 184.7[Formula: see text] at a pulling distance of wire for 11 mm, while the yawing angle was 170.4[Formula: see text] at 11 mm. The robotic catheter could attain the simultaneous two- degree-of-freedom motions in a simulated cardiac chamber. The results indicate that the four-wire-driven robotic catheter may offer physicians the opportunity to intuitively control a catheter and smoothly approach the focus position that they aim to ablate.
Chatta, Dani; Cottrell, Lewis; Burnett, Bruce; Laverty, Garry; McConville, Christopher
2015-10-01
To develop an epirubicin-loaded, water-soluble mucoadhesive gels that have the correct rheological properties to facilitate their delivery into the bladder via a catheter, while allowing for their spread across the bladder wall with limited expansion of the bladder and increasing the retention of epirubicin in the bladder and flushing with urine. Epirubicin-loaded hydroxyl ethyl cellulose (HEC) and hydroxy propyl methyl cellulose (HPMC) gels were manufactured and tested for their rheological properties. Their ability to be pushed through a catheter was also assessed as was their in-vitro drug release, spreading in a bladder and retention of epirubicin after flushing with simulated urine. Epirubicin drug release was viscosity-dependent. The 1 and 1.5% HEC gels and the 1, 1.5 and 2% HPMC gels had the correct viscosity to be administered through a model catheter and spread evenly across the bladder wall under the pressure of the detrusor muscle. The epirubicin-loaded gels had an increased retention time in the bladder when compared with a standard intravesical solution of epirubicin, even after successive flushes with simulated urine. The increased retention of epirubicin in the bladder by the HEC and HPMC gels warrant further investigation, using an in-vivo model, to assess their potential for use as treatment for non-muscle-invasive bladder cancer. © 2015 Royal Pharmaceutical Society.
García-Blas, Sergio; Núñez, Julio; Mainar, Luis; Miñana, Gema; Bonanad, Clara; Racugno, Paolo; Rodríguez, Juan Carlos; Moyano, Patricia; Sanchis, Juan
2015-01-01
Objective The aim of this study was to describe our initial experience with the GuideLiner® catheter (Vascular Solutions Inc.) in the transradial treatment of complex lesions. Materials and Methods The clinical, angiographic and procedural data of percutaneous coronary interventions where GuideLiner was used during 2013 were collected. The transradial approach was used in all cases. The indication for its use, efficacy and periprocedural complications were determined. Sixteen consecutive procedures (in 15 patients; 12 males and 3 females) were evaluated. The indication for the use of GuideLiner was a difficulty to advance and properly position a stent through a tortuous and/or calcified artery despite using high-support guide catheters or other useful techniques. Results Of the 16 angiographic procedures, 14 (87.5s%) were successful (stent deployment in 13 cases and a drug-eluting balloon in 1 case). Unsuccessful cases were a chronic total occlusion and a diffusely diseased left anterior descendant artery. A type B dissection of a proximal left circumflex artery was the only periprocedural complication. Conclusion Use of the GuideLiner was an effective and safe technique for the percutaneous treatment of complex coronary lesions in which the adequate progress of angioplasty devices had failed. GuideLiner was particularly helpful when using the transradial approach. Only one minor complication was recorded. PMID:25531292
García-Blas, Sergio; Núñez, Julio; Mainar, Luis; Miñana, Gema; Bonanad, Clara; Racugno, Paolo; Rodríguez, Juan Carlos; Moyano, Patricia; Sanchis, Juan
2015-01-01
The aim of this study was to describe our initial experience with the GuideLiner® catheter (Vascular Solutions Inc.) in the transradial treatment of complex lesions. The clinical, angiographic and procedural data of percutaneous coronary interventions where GuideLiner was used during 2013 were collected. The transradial approach was used in all cases. The indication for its use, efficacy and periprocedural complications were determined. Sixteen consecutive procedures (in 15 patients; 12 males and 3 females) were evaluated. The indication for the use of GuideLiner was a difficulty to advance and properly position a stent through a tortuous and/or calcified artery despite using high-support guide catheters or other useful techniques. Of the 16 angiographic procedures, 14 (87.5%) were successful (stent deployment in 13 cases and a drug-eluting balloon in 1 case). Unsuccessful cases were a chronic total occlusion and a diffusely diseased left anterior descendant artery. A type B dissection of a proximal left circumflex artery was the only periprocedural complication. Use of the GuideLiner was an effective and safe technique for the percutaneous treatment of complex coronary lesions in which the adequate progress of angioplasty devices had failed. GuideLiner was particularly helpful when using the transradial approach. Only one minor complication was recorded. © 2014 S. Karger AG, Basel.
Erdogan, Ali; Grumbrecht, Stephan; Neumann, Thomas; Neuzner, Joerg; Pitschner, Heinz F
2003-01-01
The aim of the study was to compare the diameter of endomyocardial lesions induced with the delivery of microwave, cooled, or pulsed energy versus conventional RF energy. In vitro tests were performed in fresh endomyocardial preparations of pig hearts in a 10-L bath of NaCl 0.9% solution at 37 degrees C and constant 1.5 L/min flow. Ablation 7 Fr catheters with 4-mm tip electrodes were used, except for the delivery of microwave energy. Energy delivery time was set to 60 s/50 W in all experiments. Cooled energy delivery was performed with a closed irrigation catheter. Pulsed energy delivery was performed using a special controller with a duty-cycle of 5 ms. Microwave energy was delivered with a 2.5-GHz generator and 10-mm antenna. Electrode temperature and impedance were measured simultaneously. After ablation, lesion length, width, and depth were measured with microcalipers, and volume calculated by a formula for ellipsoid bodies. Each energy delivery mode was tested in ten experiments. The deepest lesions were created with cooled energy delivery, and the largest volume by microwave energy delivery. Pulsed RF produced significantly deeper lesions than conventional RF energy delivery. Cooled or pulsed RF energy delivery created deeper transmural lesions than conventional RF. To create linear lesions at anatomically complex sites (isthmus), microwave energy seemed superior by rapidly creating deep and long lesions.
Femoral venous access is safe in burned children: an analysis of 224 catheters.
Goldstein, A M; Weber, J M; Sheridan, R L
1997-03-01
To document the incidence of septic and mechanical complications associated with femoral venous catheters in a subgroup of patients thought to be at particularly high risk of both: young children with large burns. An analysis of data collected prospectively on all femoral venous catheters placed during a 4-year period at a regional pediatric burn facility. There were 224 femoral catheters placed in 86 children with an average age of 5.3 +/- 5.1 years and an average burn size of 38% +/- 23%. Catheters were left in place for a mean duration of 5.7 days. Catheter-related sepsis occurred with 4.9% of the catheters, and mechanical complications occurred in 3.5% of the patients. There was no statistically significant association between the risk of catheter sepsis and the placement of catheters through burned versus unburned skin. Similarly, the risk of sepsis was equivalent between lines placed over a guide wire and those placed of a new site. Femoral venous catheters are safe in burned children and are associated with a low incidence of infectious and mechanical complications.
Frequency of puncture holes in peritoneal dialysis catheters related to the beta cap adapter.
Ohashi, Yasushi; Kansal, Sheru; Schreiber, Martin
2012-01-01
Between November 2009 and September 2011, 12 patients (6 women, 6 men) undergoing continuous peritoneal dialysis (PD) or automated PD developed puncture-like holes in the PD catheter near the interface of the adapter with the superior aspect of the Silastic PD catheter The adapter is used to connect the PD catheter to the PD transfer set. Over the course of 23 months, the 12 patients presented to the PD unit with 19 separate instances of catheter holes, for an event rate of 0.23 holes per patient-year Data including socio-demographic information, PD modality, need for antibiotic treatment, event recurrence, infectious complications, and time from catheter placement were collected from patients whose catheters did and did not develop holes. We observed no differences between patients whose catheters developed holes and those whose catheters did not. The location of the individual holes suggested a relationship between the adapter and the catheter holes. The holes, which led to increased patient morbidity and costs, may be related to structural changes made in 2006 to the adapter.
Stabille, Débora Miranda Diogo; Filho, Augusto Diogo; Mandim, Beatriz Lemos da Silva; Araújo, Lúcio Borges de; Mesquita, Priscila Miranda Diogo; Jorge, Miguel Tanús
2015-01-01
The increased use of epidural analgesia with catheter leads to the need to demonstrate the safety of this method and know the incidence of catheter colonization, inserted postoperatively for epidural analgesia, and the bacteria responsible for this colonization. From November 2011 to April 2012, patients electively operated and maintained under epidural catheter for postoperative analgesia were evaluated. The catheter tip was collected for semiquantitative and qualitative microbiological analysis. Of 68 cultured catheters, six tips (8.8%) had positive cultures. No patient had superficial or deep infection. The mean duration of catheter use was 43.45hours (18-118) (p=0.0894). The type of surgery (contaminated or uncontaminated), physical status of patients, and surgical time showed no relation with the colonization of catheters. Microorganisms isolated from the catheter tip were Staphylococcus aureus, Pseudomonas aeruginosa and Sphingomonas paucimobilis. Postoperative epidural catheter analgesia, under this study conditions, was found to be low risk for bacterial colonization in patients at surgical wards. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.
Stabille, Débora Miranda Diogo; Diogo Filho, Augusto; Mandim, Beatriz Lemos da Silva; de Araújo, Lúcio Borges; Mesquita, Priscila Miranda Diogo; Jorge, Miguel Tanús
2015-01-01
The increased use of epidural analgesia with catheter leads to the need to demonstrate the safety of this method and know the incidence of catheter colonization, inserted postoperatively for epidural analgesia, and the bacteria responsible for this colonization. From November 2011 to April 2012, patients electively operated and maintained under epidural catheter for postoperative analgesia were evaluated. The catheter tip was collected for semiquantitative and qualitative microbiological analysis. Of 68 cultured catheters, six tips (8.8%) had positive cultures. No patient had superficial or deep infection. The mean duration of catheter use was 43.45 h (18-118) (p=0.0894). The type of surgery (contaminated or uncontaminated), physical status of patients, and surgical time showed no relation with the colonization of catheters. Microorganisms isolated from the catheter tip were Staphylococcus aureus, Pseudomonas aeruginosa and Sphingomonas paucimobilis. Postoperative epidural catheter analgesia, under these study conditions, was found to be low risk for bacterial colonization in patients at surgical wards. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
Thermodynamic perspective on the dock-lock growth mechanism of amyloid fibrils.
O'Brien, Edward P; Okamoto, Yuko; Straub, John E; Brooks, Bernard R; Thirumalai, D
2009-10-29
The mechanism of addition of a soluble unstructured monomer to a preformed ordered amyloid fibril is a complex process. On the basis of the kinetics of monomer disassociation of Abeta(1-40) from the amyloid fibril, it has been suggested that deposition is a multistep process involving a rapid reversible association of the unstructured monomer to the fibril surface (docking) followed by a slower conformational rearrangement leading to the incorporation onto the underlying fibril lattice (locking). By exploiting the vast time scale separation between the dock and lock processes and using molecular dynamics simulation of deposition of the disordered peptide fragment (35)MVGGVV(40) from the Abeta peptide onto the fibril with known crystal structure, we provide a thermodynamic basis for the dock-lock mechanism of fibril growth. Free energy profiles, computed using implicit solvent model and enhanced sampling methods with the distance (delta(C)) between the center of mass of the peptide and the fibril surface as the order parameter, show three distinct basins of attraction. When delta(C) is large, the monomer is compact and unstructured and the favorable interactions with the fibril results in stretching of the peptide at delta(C) approximately 13 A. As delta(C) is further decreased, the peptide docks onto the fibril surface with a structure that is determined by a balance between intrapeptide and peptide fibril interactions. At delta(C) approximately 4 A, a value that is commensurate with the spacing between beta-strands in the fibril, the monomer expands and locks onto the fibril. Using simulations with implicit solvent model and all atom molecular dynamics in explicit water, we show that the locked monomer, which interacts with the underlying fibril, undergoes substantial conformational fluctuations and is not stable. The cosolutes urea and TMAO destabilize the unbound phase and stabilize the docked phase. Interestingly, small crowding particles enhance the stability of the fibril-bound monomer only marginally. We predict that the experimentally measurable critical monomer concentration, C(R), at which the soluble unbound monomer is in equilibrium with the ordered fibril, increases sharply as temperature is increased under all solution conditions.
Between the lines: The 50th anniversary of long-term central venous catheters.
Gow, Kenneth W; Tapper, David; Hickman, Robert O
2017-05-01
Tunneled central venous catheters (CVC) were developed five decades ago. Since then, several clinician-inventors have created a variety of catheters with different functions. Indeed, many catheters have been named after their inventor. Many have wondered who the inventors were of each catheter, and what specifically inspired their inventions. Many of these compelling stories have yet to be told. A literature review of common catheters and personal communication with inventors. Only first person accounts from inventors or those close to the invention were used. CVCs are now essential devices that have saved countless lives. Though the inventors have earned the honor of naming their catheters, it may be reasonable to consider more consistent terminology to describe these catheters to avoid confusion. Copyright © 2017 Elsevier Inc. All rights reserved.
SU-F-T-20: Novel Catheter Lumen Recognition Algorithm for Rapid Digitization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dise, J; McDonald, D; Ashenafi, M
Purpose: Manual catheter recognition remains a time-consuming aspect of high-dose-rate brachytherapy (HDR) treatment planning. In this work, a novel catheter lumen recognition algorithm was created for accurate and rapid digitization. Methods: MatLab v8.5 was used to create the catheter recognition algorithm. Initially, the algorithm searches the patient CT dataset using an intensity based k-means filter designed to locate catheters. Once the catheters have been located, seed points are manually selected to initialize digitization of each catheter. From each seed point, the algorithm searches locally in order to automatically digitize the remaining catheter. This digitization is accomplished by finding pixels withmore » similar image curvature and divergence parameters compared to the seed pixel. Newly digitized pixels are treated as new seed positions, and hessian image analysis is used to direct the algorithm toward neighboring catheter pixels, and to make the algorithm insensitive to adjacent catheters that are unresolvable on CT, air pockets, and high Z artifacts. The algorithm was tested using 11 HDR treatment plans, including the Syed template, tandem and ovoid applicator, and multi-catheter lung brachytherapy. Digitization error was calculated by comparing manually determined catheter positions to those determined by the algorithm. Results: he digitization error was 0.23 mm ± 0.14 mm axially and 0.62 mm ± 0.13 mm longitudinally at the tip. The time of digitization, following initial seed placement was less than 1 second per catheter. The maximum total time required to digitize all tested applicators was 4 minutes (Syed template with 15 needles). Conclusion: This algorithm successfully digitizes HDR catheters for a variety of applicators with or without CT markers. The minimal axial error demonstrates the accuracy of the algorithm, and its insensitivity to image artifacts and challenging catheter positioning. Future work to automatically place initial seed positions would improve the algorithm speed.« less
Capone, Christine A; Ceresnak, Scott R; Nappo, Lynn; Gates, Gregory J; Schechter, Clyde B; Pass, Robert H
2015-12-01
To compare the efficacy, safety, and cost-effectiveness of a three-catheter approach with a conventional five-catheter approach for the mapping and ablation of supraventricular tachycardia in pediatric patients with Wolff-Parkinson-White Syndrome (WPW) and concealed accessory pathways (APs). A retrospective review from 2008 to 2012 of patients less than 21 years with WPW who underwent a three-catheter radiofrequency (RF) ablation of a left-sided AP (ablation, right ventricular [RV] apical, and coronary sinus [CS] decapolar catheters) was performed. The three-catheter group was compared to a control group who underwent a standard five-catheter (ablation, RV apical, CS decapolar, His catheter, and right atrial catheter) ablation for the treatment of left-sided WPW or concealed AP. Demographics, ablation outcomes, and costs were compared between groups. Twenty-eight patients met inclusion criteria with 28 control patients. The groups did not differ in gender, age, weight, or body surface area. Locations of the AP on the mitral annulus were similar between the groups. All patients were ablated via transseptal approach. Note that 28 of 28 in the three-catheter group (100%) and 27 of 28 (96%) controls were acutely successfully ablated (P = 0.31). No complications were encountered. There was no difference in procedural time, time to loss of AP conduction, or number of RF applications. Use of the three-catheter technique resulted in a total savings of $2,465/case, which includes the $680 savings from using fewer catheters as well as the savings from a shortened procedure time. Ablation in patients with WPW and a left-sided AP can be performed using three catheters with similar efficacy and safety while offering significant cost savings compared to a conventional five-catheter approach. © 2015 Wiley Periodicals, Inc.
Moonens, F; el Alami, S; Van Gossum, A; Struelens, M J; Serruys, E
1994-01-01
The accuracy of Gram staining of blood drawn from catheters used to administer total parenteral nutrition was compared with paired quantitative blood cultures for the diagnosis of catheter-related sepsis. Gram staining was positive in 11 of 18 episodes of catheter-related sepsis documented by quantitative culture (sensitivity, 61%) but in none of the 5 episodes of fever unrelated to catheter infection. Thus, this procedure enabled the rapid presumptive diagnosis and guidance of antimicrobial therapy for total parenteral nutrition catheter sepsis, with a positive predictive value of 100% and a negative predictive value of 42%. PMID:7521359
21 CFR 870.1200 - Diagnostic intravascular catheter.
Code of Federal Regulations, 2010 CFR
2010-04-01
... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...
21 CFR 870.1200 - Diagnostic intravascular catheter.
Code of Federal Regulations, 2012 CFR
2012-04-01
... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...
21 CFR 870.1200 - Diagnostic intravascular catheter.
Code of Federal Regulations, 2011 CFR
2011-04-01
... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...
21 CFR 870.1200 - Diagnostic intravascular catheter.
Code of Federal Regulations, 2013 CFR
2013-04-01
... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...
21 CFR 870.1200 - Diagnostic intravascular catheter.
Code of Federal Regulations, 2014 CFR
2014-04-01
... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...
Shavit, L; Lifschitz, M; Plaksin, J; Grenader, T; Slotki, I
2010-10-01
Catheter thrombosis is common and results in inadequate dialysis treatment and, frequently, in catheter loss. Since dialysis treatment runs on a strict schedule, occluded catheters need to be restored in a timely and cost effective manner. We present a new shortened protocol of urokinase infusion that allows hemodialysis to be performed within 90 minutes. To chronic hemodialysis patients, who developed complete catheter occlusion, urokinase was infused simultaneously through both lumens of the catheter (125,000 units to each lumen) over 90 minutes. Technical success was defined as restoring blood pump speed to at least 250 ml/min. We determined the average time from catheter placement to first clot event (primary patency PP), recurrent clot event after urokinase treatment (secondary patency SP), catheter salvage rate and cause for removal. 37 catheters developed total thrombosis and urokinase was used to restore patency one or more times (total 47 treatments). Catheter salvage rate was 97 %. The average time of PP was 152 ± 56 days (7 - 784 days). Nine patients (30%) developed recurrent occlusion and the average time of SP was 64 ± 34 days (2 - 364 days). One catheter was removed because of dysfunction due to thrombosis. Other catheters were removed due to infection, fistula maturation or fell out spontaneously. Hemodialysis was performed immediately after treatment with blood speed of 250 ml/min in all patients. Our protocol is highly effective, short, and allows to restore patency of totally occluded central venous catheters with minimal disruption of the dialysis session.
Arokiaraj, Mark Christopher
2018-02-01
Difficulty in engaging with guide catheters is not uncommon in acute emergencies. We aimed to evaluate the use of Cordis ® INFINITI diagnostic catheters to perform angioplasty in patients in whom the coronaries cannot be engaged using standard guide catheters. In 34 cases of acute coronary syndrome, when difficulty in engagement with two standard guide catheters was encountered with reasonable manipulations, angioplasty was performed using diagnostic catheters. In total, 40 stents were placed by this technique. Pushability and trackability, distal tip flexion and three-point bending tests were performed to evaluate the performance of the guide and diagnostic catheters. Angioplasty was performed easily in a setting where it would have been very difficult to perform. Coronary dissection occurred in one patient, treated by a stent. The stent and dilatation balloons were easily passed through the diagnostic catheters. Pressure tracings were clearly preserved with certain stent delivery systems, and at angioplasty, although there was slightly reduced opacification of the respective artery, the coronary anatomy was sufficiently visualized to perform angioplasty. No periprocedural target lesion complications were seen in any cases. Pushability and trackability tests showed good force transmission along a tortuous path with diagnostic catheters, and balanced force-displacement curves from three-point bending tests and distal tip softness tests. Angioplasty with stenting can be performed safely through 6F Cordis ® infiniti diagnostic catheters when difficulty in engaging guide catheters is encountered. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.
Choline deficiency is associated with increased risk for venous catheter thrombosis.
Buchman, Alan L; Ament, Marvin E; Jenden, Donald J; Ahn, Chul
2006-01-01
Patients with intestinal failure who require long-term parenteral nutrition (PN) develop catheter thrombosis as a complication. This patient group may also develop choline deficiency because of a defect in the hepatic transsulfuration pathway in the setting of malabsorption. This study was undertaken to determine whether choline deficiency is a risk factor for development of catheter thrombosis. Plasma free and phospholipid-bound choline concentrations were measured in a group of 41 patients that required long-term PN. Episodes of catheter thrombosis from onset of PN to the time of blood testing were recorded. Sixteen (39%) patients developed catheter thrombosis, and 5 of these had recurrent catheter thrombosis. Plasma free choline was 7.7 +/- 2.7 nmol/mL in patients with no history of catheter thrombosis and 6.2 +/- 1.7 nmol/mL in patients with previous catheter thrombosis (p = .076 by Wilcoxon rank-sum test). The partial correlation between plasma free choline concentration and the frequency of clots after controlling for catheter duration was r = -0.33 (p = .038). The relative risk for catheter thrombosis in subjects with a plasma free choline concentration <8 nmol/mL was 10.0, 95% confidence interval (1.134-88.167). Plasma phospholipid-bound choline concentration was 2191.7 +/- 679.0 nmol/mL in patients with previous catheter thrombosis and 2103.3 +/- 531.2 nmol/mL in patients without history of catheter thrombosis (p = NS). Choline deficiency is a significant risk factor for development of catheter thrombosis in patients with intestinal failure who require PN.
Catheter-related bloodstream infection.
Goede, Matthew R; Coopersmith, Craig M
2009-04-01
Catheter-related bloodstream infections (CR-BSIs) are a common, frequently preventable complication of central venous catheterization. CR-BSIs can be prevented by strict attention to insertion and maintenance of central venous catheters and removing unneeded catheters as soon as possible. Antiseptic- or antibiotic-impregnated catheters are also an effective tool to prevent infections. The diagnosis of CR-BSI is made largely based on culture results. CR-BSIs should always be treated with antibiotics, and except in rare circumstances the infected catheter needs to be removed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lucey, Brian; Varghese, Jose C.; Haslam, Philip
1999-09-15
Purpose: To study the cost and impact on patient management of the routine performance of chest radiographs in patients undergoing imaged-guided central venous catheter insertion. Methods: Six hundred and twenty-one catheters placed in 489 patients over a 42-month period formed the study group. Catheters were placed in the right internal jugular vein (425), left internal jugular vein (133), and subclavian veins (63). At the end of the procedure fluoroscopy was used to assess catheter position and check for complications. A postprocedural chest radiograph was obtained in all patients. Results: Postprocedural chest fluoroscopy showed no evidence of pneumothorax, hemothorax, or mediastinalmore » hematoma. Inappropriate catheter tip position or catheter kinks were noted with 90 catheters. These problems were all corrected while the patient was on the interventional table. Postprocedural chest radiographs showed no complications but proximal catheter tip migration was noted in six of 621 catheters (1%). These latter six catheters required further manipulation. The total technical and related charges for the postprocedural chest radiographs in this series were estimated at Pounds 15,525. Conclusion: Postprocedural chest radiographs after image-guided central venous catheter insertion are not routinely required. A postprocedural chest radiograph can be performed on a case-by-case basis at the discretion of the interventional radiologist.« less
Discriminating Tissue Stiffness with a Haptic Catheter: Feeling the Inside of the Beating Heart.
Kesner, Samuel B; Howe, Robert D
2011-01-01
Catheter devices allow physicians to access the inside of the human body easily and painlessly through natural orifices and vessels. Although catheters allow for the delivery of fluids and drugs, the deployment of devices, and the acquisition of the measurements, they do not allow clinicians to assess the physical properties of tissue inside the body due to the tissue motion and transmission limitations of the catheter devices, including compliance, friction, and backlash. The goal of this research is to increase the tactile information available to physicians during catheter procedures by providing haptic feedback during palpation procedures. To accomplish this goal, we have developed the first motion compensated actuated catheter system that enables haptic perception of fast moving tissue structures. The actuated catheter is instrumented with a distal tip force sensor and a force feedback interface that allows users to adjust the position of the catheter while experiencing the forces on the catheter tip. The efficacy of this device and interface is evaluated through a psychophyisical study comparing how accurately users can differentiate various materials attached to a cardiac motion simulator using the haptic device and a conventional manual catheter. The results demonstrate that haptics improves a user's ability to differentiate material properties and decreases the total number of errors by 50% over the manual catheter system.
A computational fluid dynamics simulation framework for ventricular catheter design optimization.
Weisenberg, Sofy H; TerMaath, Stephanie C; Barbier, Charlotte N; Hill, Judith C; Killeffer, James A
2017-11-10
OBJECTIVE Cerebrospinal fluid (CSF) shunts are the primary treatment for patients suffering from hydrocephalus. While proven effective in symptom relief, these shunt systems are plagued by high failure rates and often require repeated revision surgeries to replace malfunctioning components. One of the leading causes of CSF shunt failure is obstruction of the ventricular catheter by aggregations of cells, proteins, blood clots, or fronds of choroid plexus that occlude the catheter's small inlet holes or even the full internal catheter lumen. Such obstructions can disrupt CSF diversion out of the ventricular system or impede it entirely. Previous studies have suggested that altering the catheter's fluid dynamics may help to reduce the likelihood of complete ventricular catheter failure caused by obstruction. However, systematic correlation between a ventricular catheter's design parameters and its performance, specifically its likelihood to become occluded, still remains unknown. Therefore, an automated, open-source computational fluid dynamics (CFD) simulation framework was developed for use in the medical community to determine optimized ventricular catheter designs and to rapidly explore parameter influence for a given flow objective. METHODS The computational framework was developed by coupling a 3D CFD solver and an iterative optimization algorithm and was implemented in a high-performance computing environment. The capabilities of the framework were demonstrated by computing an optimized ventricular catheter design that provides uniform flow rates through the catheter's inlet holes, a common design objective in the literature. The baseline computational model was validated using 3D nuclear imaging to provide flow velocities at the inlet holes and through the catheter. RESULTS The optimized catheter design achieved through use of the automated simulation framework improved significantly on previous attempts to reach a uniform inlet flow rate distribution using the standard catheter hole configuration as a baseline. While the standard ventricular catheter design featuring uniform inlet hole diameters and hole spacing has a standard deviation of 14.27% for the inlet flow rates, the optimized design has a standard deviation of 0.30%. CONCLUSIONS This customizable framework, paired with high-performance computing, provides a rapid method of design testing to solve complex flow problems. While a relatively simplified ventricular catheter model was used to demonstrate the framework, the computational approach is applicable to any baseline catheter model, and it is easily adapted to optimize catheters for the unique needs of different patients as well as for other fluid-based medical devices.
Changing concepts in long-term central venous access: catheter selection and cost savings.
Horattas, M C; Trupiano, J; Hopkins, S; Pasini, D; Martino, C; Murty, A
2001-02-01
Long-term central venous access is becoming an increasingly important component of health care today. Long-term central venous access is important therapeutically for a multitude of reasons, including the administration of chemotherapy, antibiotics, and total parenteral nutrition. Central venous access can be established in a variety of ways varying from catheters inserted at the bedside to surgically placed ports. Furthermore, in an effort to control costs, many traditionally inpatient therapies have moved to an outpatient setting. This raises many questions regarding catheter selection. Which catheter will result in the best outcome at the least cost? It has become apparent in our hospital that traditionally placed surgical catheters (ie, Hickmans and central venous ports) may no longer be the only options. The objective of this study was to explore the various modalities for establishing central venous access comparing indications, costs, and complications to guide the clinician in choosing the appropriate catheter with the best outcome at the least cost. We evaluated our institution's central venous catheter use during a 3-year period from 1995 through 1997. Data was obtained retrospectively through chart review. In addition to demographic data, specific information regarding catheter type, placement technique, indications, complications, and catheter history were recorded. Cost data were obtained from several departments including surgery, radiology, nursing, anesthesia, pharmacy, and the hospital purchasing department. During a 30-month period, 684 attempted central venous catheter insertions were identified, including 126 surgically placed central venous catheters, 264 peripherally inserted central catheters by the nursing service, and 294 radiologically inserted peripheral ports. Overall complications were rare but tended to be more severe in the surgical group. Relative cost differences between the groups were significant. Charges for peripherally inserted central catheters were $401 per procedure, compared with $3870 for radiologically placed peripheral ports and $3532 to $4296 for surgically placed catheters. Traditional surgically placed central catheters are increasingly being replaced by peripherally inserted central venous access devices. Significant cost savings and fewer severe complications can be realized by preferential use of peripherally inserted central catheters when clinically indicated. Cost savings may not be as significant when comparing radiologically placed versus surgically placed catheters. However, significant cost savings and fewer severe complications are associated with peripheral central venous access versus the surgical or radiologic approach.
2010-11-18
protection of human subjects. No human subjects were directly involved in this research. FFPPT Materiel Solutions ii Executive Summary The Naval Health...OD 7FR CATHETER BALLOON OCCLUSI EA 6 10 0.180 0.180 918.96 0.300 0.300 1,531.60 C 6840014763011 DISINFECTANT INSTRUMT CIDEX 1GL BT 4S PG 8 1...2-0 1 27IN STRAND NDL T-5 GUT NATURAL BR 36S PG 4 1 0.800 0.120 215.44 0.200 0.030 53.86 B 6515012192747 SUTURE ABS GI SZ 2-0 27IN NDL VICRYL 3S
FAQs about Catheter-Associated Urinary Tract Infection
... and nurses take the following actions. Catheter insertion o Catheters are put in only when necessary and they are removed as soon as possible. o Only properly trained persons insert catheters using sterile (“ ...
Newton, Terry; Still, Joseph M; Law, Edward
2002-04-01
A retrospective study was designed to compare the incidence of urinary tract infections during two different time periods in burn patients treated with two different types of Foley catheters. In time period 1, latex catheters present on admission were not changed. In time period 2, catheters were replaced on admission with silver alloy-impregnated catheters. In time period 1, the rate of symptomatic urinary tract infections was 7.2 per 1,000 catheter-days. In time period 2, the rate was 4.4 per 1,000 catheter-days. Results, compared using Fisher's exact test, revealed a statistically significant P value of .029. The use of silver-impregnated catheters significantly lowered the rate of urinary tract infection at our burn center.
Kuno, Toshiki; Fujisawa, Taishi; Yamazaki, Hiroyuki; Motoda, Hiroyuki; Kodaira, Masaki; Numasawa, Yohei
2015-01-01
Percutaneous coronary intervention for anomalous right coronary artery (RCA) originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin.
Magnetic resonance imaging compatible remote catheter navigation system with 3 degrees of freedom.
Tavallaei, M A; Lavdas, M K; Gelman, D; Drangova, M
2016-08-01
To facilitate MRI-guided catheterization procedures, we present an MRI-compatible remote catheter navigation system that allows remote navigation of steerable catheters with 3 degrees of freedom. The system consists of a user interface (master), a robot (slave), and an ultrasonic motor control servomechanism. The interventionalist applies conventional motions (axial, radial and plunger manipulations) on an input catheter in the master unit; this user input is measured and used by the servomechanism to control a compact catheter manipulating robot, such that it replicates the interventionalist's input motion on the patient catheter. The performance of the system was evaluated in terms of MRI compatibility (SNR and artifact), feasibility of remote navigation under real-time MRI guidance, and motion replication accuracy. Real-time MRI experiments demonstrated that catheter was successfully navigated remotely to desired target references in all 3 degrees of freedom. The system had an absolute value error of [Formula: see text]1 mm in axial catheter motion replication over 30 mm of travel and [Formula: see text] for radial catheter motion replication over [Formula: see text]. The worst case SNR drop was observed to be [Formula: see text]3 %; the robot did not introduce any artifacts in the MR images. An MRI-compatible compact remote catheter navigation system has been developed that allows remote navigation of steerable catheters with 3 degrees of freedom. The proposed system allows for safe and accurate remote catheter navigation, within conventional closed-bore scanners, without degrading MR image quality.
Kanematsu, Hideyuki; Kudara, Hikonaru; Kanesaki, Shun; Kogo, Takeshi; Ikegai, Hajime; Ogawa, Akiko; Hirai, Nobumitsu
2016-10-11
A laboratory biofilm reactor (LBR) was modified to a new loop-type closed system in order to evaluate novel stents and catheter materials using 3D optical microscopy and Raman spectroscopy. Two metallic specimens, pure nickel and cupronickel (80% Cu-20% Ni), along with two polymers, silicone and polyurethane, were chosen as examples to ratify the system. Each set of specimens was assigned to the LBR using either tap water or an NB (Nutrient broth based on peptone from animal foods and beef extract mainly)-cultured solution with E-coli formed over 48-72 h. The specimens were then analyzed using Raman Spectroscopy. 3D optical microscopy was employed to corroborate the Raman Spectroscopy results for only the metallic specimens since the inherent roughness of the polymer specimens made such measurements difficult. The findings suggest that the closed loop-type LBR together with Raman spectroscopy analysis is a useful method for evaluating biomaterials as a potential urinary system.
Multisensory System for the Detection and Localization of Peripheral Subcutaneous Veins
Fernández, Roemi; Armada, Manuel
2017-01-01
This paper proposes a multisensory system for the detection and localization of peripheral subcutaneous veins, as a first step for achieving automatic robotic insertion of catheters in the near future. The multisensory system is based on the combination of a SWIR (Short-Wave Infrared) camera, a TOF (Time-Of-Flight) camera and a NIR (Near Infrared) lighting source. The associated algorithm consists of two main parts: one devoted to the features extraction from the SWIR image, and another envisaged for the registration of the range data provided by the TOF camera, with the SWIR image and the results of the peripheral veins detection. In this way, the detected subcutaneous veins are mapped onto the 3D reconstructed surface, providing a full representation of the region of interest for the automatic catheter insertion. Several experimental tests were carried out in order to evaluate the capabilities of the presented approach. Preliminary results demonstrate the feasibility of the proposed design and highlight the potential benefits of the solution. PMID:28422075
Central venous catheter-related bloodstream infections in the intensive care unit
Patil, Harsha V.; Patil, Virendra C.; Ramteerthkar, M. N.; Kulkarni, R. D.
2011-01-01
Context: Central venous catheter-related bloodstream infection (CRBSI) is associated with high rates of morbidity and mortality in critically ill patients. Aims: This study was conducted to determine the incidence of central venous catheter-related infections (CRIs) and to identify the factors influencing it. So far, there are very few studies that have been conducted on CRBSI in the intensive care unit in India. Settings and Design: This was a prospective, observational study carried out in the medical intensive care unit (MICU) over a period of 1 year from January to December 2004. Materials and Methods: A total of 54 patients with indwelling central venous catheters of age group between 20 and 75 years were included. The catheters were cultured using the standard semiquantitative culture (SQC) method. Statistical analysis used SPSS-10 version statistical software. Results: A total of 54 CVC catheters with 319 catheter days were included in this study. Of 54 patients with CVCs studied for bacteriology, 39 (72.22%) catheters showed negative SQCs and also negative blood cultures. A total of 15 (27.77%) catheters were positive on SQC, of which 10 (18.52%) were with catheter-associated infection and four (7.41%) were with catheter-associated bacteremia; the remaining one was a probable catheter-associated bacteremia. CRIs were high among catheters that were kept in situ for more than 3 days and emergency procedures where two or more attempts were required for catheterization (P < 0.05). In multivariate analysis of covariance duration of catheter in situ for >3 days, inexperienced venupucturist, more number of attempts and emergency CVC were associated with more incidence of CVCBSIs, with P <0.02. The duration of catheter in situ was negatively correlated (-0.53) and number of attempts required to put CVC was positively correlated (+0.39) with incidence of CVCBSIs. Sixty-five percent of the isolates belonged to the CONS group (13/20). Staphylococcus epidermidis showed maximum susceptibility to amikacin, doxycycline and amoxycillin with clavulanic acid and was susceptible to vancomycin (100%). Klebsiella pneumoniae was 100% susceptible to amikacin and ciprofloxacin. Escherichia coli was susceptible to amikacin and cefotaxime. Conclusions: The overall incidence of CRI was 27.77% (15/54). Catheter-associated BSIs were 47.31 per 1000 catheter-days. CRI was low in the catheters inserted by the experienced venipuncturists, elective procedure and CVC kept in situ for ≤3 days. S. epidermidis was the most common isolate. PMID:22346032
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma Yingliang; Housden, R. James; Razavi, Reza
2013-07-15
Purpose: X-ray fluoroscopically guided cardiac electrophysiology (EP) procedures are commonly carried out to treat patients with arrhythmias. X-ray images have poor soft tissue contrast and, for this reason, overlay of a three-dimensional (3D) roadmap derived from preprocedural volumetric images can be used to add anatomical information. It is useful to know the position of the catheter electrodes relative to the cardiac anatomy, for example, to record ablation therapy locations during atrial fibrillation therapy. Also, the electrode positions of the coronary sinus (CS) catheter or lasso catheter can be used for road map motion correction.Methods: In this paper, the authors presentmore » a novel unified computational framework for image-based catheter detection and tracking without any user interaction. The proposed framework includes fast blob detection, shape-constrained searching and model-based detection. In addition, catheter tracking methods were designed based on the customized catheter models input from the detection method. Three real-time detection and tracking methods are derived from the computational framework to detect or track the three most common types of catheters in EP procedures: the ablation catheter, the CS catheter, and the lasso catheter. Since the proposed methods use the same blob detection method to extract key information from x-ray images, the ablation, CS, and lasso catheters can be detected and tracked simultaneously in real-time.Results: The catheter detection methods were tested on 105 different clinical fluoroscopy sequences taken from 31 clinical procedures. Two-dimensional (2D) detection errors of 0.50 {+-} 0.29, 0.92 {+-} 0.61, and 0.63 {+-} 0.45 mm as well as success rates of 99.4%, 97.2%, and 88.9% were achieved for the CS catheter, ablation catheter, and lasso catheter, respectively. With the tracking method, accuracies were increased to 0.45 {+-} 0.28, 0.64 {+-} 0.37, and 0.53 {+-} 0.38 mm and success rates increased to 100%, 99.2%, and 96.5% for the CS, ablation, and lasso catheters, respectively. Subjective clinical evaluation by three experienced electrophysiologists showed that the detection and tracking results were clinically acceptable.Conclusions: The proposed detection and tracking methods are automatic and can detect and track CS, ablation, and lasso catheters simultaneously and in real-time. The accuracy of the proposed methods is sub-mm and the methods are robust toward low-dose x-ray fluoroscopic images, which are mainly used during EP procedures to maintain low radiation dose.« less
Urological considerations in space medicine.
NASA Technical Reports Server (NTRS)
Cockett, A. T. K.; Adey, W. R.; Roberts, A. P.
1972-01-01
Urological problems encountered during the preparation phases of Biosatellite III, flight of Bonny the Space Monkey, are detailed. The solution to each problem is detailed. The catheter system employed, antibiotic coverage used, and bacteria encountered in the urine of the five animals are detailed. Urinary calcium levels in three ground based animals are illustrated. Testicular alterations encountered in all animals are mentioned. It is concluded that space flights of duration beyond nine days may present serious problems of a urological nature.
van de Wetering, M D; van Woensel, J B M; Kremer, L C M; Caron, H N
2005-05-01
Long-term tunnelled central venous catheters (TCVC) are increasingly used in oncology patients. Infections are a frequent complication of TCVC, mostly caused by Gram-positive bacteria. The objective of this review is to evaluate the efficacy of antibiotics in the prevention of early Gram-positive TCVC infections, in oncology patients. We searched MEDLINE, EMBASE, and the Cochrane Controlled Trials Register up to July 2003. We selected randomised controlled trials (RCT) evaluating prophylactic antibiotics prior to insertion of the TCVC, and the combination of an antibiotic and heparin to flush the TCVC, in paediatric and adult oncology patients. The primary outcome was documented Gram-positive bacteraemia in patients with a TCVC. All trials identified were assessed and the data extracted independently by two reviewers. There were nine trials included. Four trials reported on vancomycin/teicoplanin prior to insertion of the TCVC compared to no antibiotics. There was no reduction in the number of Gram-positive TCVC infections with an Odds ratio of 0.42 (95% confidence interval 0.13-1.31). Five trials studied flushing of the TCVC with a vancomycin/heparin solution compared to heparin flushing only. This method decreased the number of TCVC infections significantly with an Odds ratio of 0.43 (95% CI 0.21-0.87). Flushing the TCVC with a vancomycin/heparin solution reduced the incidence of Gram-positive infections.
Design of a visible-light spectroscopy clinical tissue oximeter.
Benaron, David A; Parachikov, Ilian H; Cheong, Wai-Fung; Friedland, Shai; Rubinsky, Boris E; Otten, David M; Liu, Frank W H; Levinson, Carl J; Murphy, Aileen L; Price, John W; Talmi, Yair; Weersing, James P; Duckworth, Joshua L; Hörchner, Uwe B; Kermit, Eben L
2005-01-01
We develop a clinical visible-light spectroscopy (VLS) tissue oximeter. Unlike currently approved near-infrared spectroscopy (NIRS) or pulse oximetry (SpO2%), VLS relies on locally absorbed, shallow-penetrating visible light (475 to 625 nm) for the monitoring of microvascular hemoglobin oxygen saturation (StO2%), allowing incorporation into therapeutic catheters and probes. A range of probes is developed, including noncontact wands, invasive catheters, and penetrating needles with injection ports. Data are collected from: 1. probes, standards, and reference solutions to optimize each component; 2. ex vivo hemoglobin solutions analyzed for StO2% and pO2 during deoxygenation; and 3. human subject skin and mucosal tissue surfaces. Results show that differential VLS allows extraction of features and minimization of scattering effects, in vitro VLS oximetry reproduces the expected sigmoid hemoglobin binding curve, and in vivo VLS spectroscopy of human tissue allows for real-time monitoring (e.g., gastrointestinal mucosal saturation 69+/-4%, n=804; gastrointestinal tumor saturation 45+/-23%, n=14; and p<0.0001), with reproducible values and small standard deviations (SDs) in normal tissues. FDA approved VLS systems began shipping earlier this year. We conclude that VLS is suitable for the real-time collection of spectroscopic and oximetric data from human tissues, and that a VLS oximeter has application to the monitoring of localized subsurface hemoglobin oxygen saturation in the microvascular tissue spaces of human subjects.
Anti-fouling strategies for central venous catheters
Albadawi, Hassan; Patel, Nikasha; Khademhosseini, Ali; Zhang, Yu Shrike; Naidu, Sailendra; Knuttinen, Grace; Oklu, Rahmi
2017-01-01
Central venous catheters (CVCs) are ubiquitous in the healthcare industry and carry two common complications, catheter related infections and occlusion, particularly by thrombus. Catheter-related bloodstream infections (CRBSI) are an important cause of nosocomial infections that increase patient morbidity, mortality, and hospital cost. Innovative design strategies for intravenous catheters can help reduce these preventable infections. Antimicrobial coatings can play a major role in preventing disease. These coatings can be divided into two major categories: drug eluting and non-drug eluting. Much of these catheter designs are targeted at preventing the formation of microbial biofilms that make treatment of CRBSI nearly impossible without removal of the intravenous device. Exciting developments in catheter impregnation with antibiotics as well as nanoscale surface design promise innovative changes in the way that physicians manage intravenous catheters. Occlusion of a catheter renders the catheter unusable and is often treated by tissue plasminogen activator administration or replacement of the line. Prevention of this complication requires a thorough understanding of the mechanisms of platelet aggregation, signaling and cross-linking. This article will look at the advances in biomaterial design specifically drug eluting, non-drug eluting, lubricious coatings and micropatterning as well as some of the characteristics of each as they relate to CVCs. PMID:29399528
Anti-fouling strategies for central venous catheters.
Wallace, Alex; Albadawi, Hassan; Patel, Nikasha; Khademhosseini, Ali; Zhang, Yu Shrike; Naidu, Sailendra; Knuttinen, Grace; Oklu, Rahmi
2017-12-01
Central venous catheters (CVCs) are ubiquitous in the healthcare industry and carry two common complications, catheter related infections and occlusion, particularly by thrombus. Catheter-related bloodstream infections (CRBSI) are an important cause of nosocomial infections that increase patient morbidity, mortality, and hospital cost. Innovative design strategies for intravenous catheters can help reduce these preventable infections. Antimicrobial coatings can play a major role in preventing disease. These coatings can be divided into two major categories: drug eluting and non-drug eluting. Much of these catheter designs are targeted at preventing the formation of microbial biofilms that make treatment of CRBSI nearly impossible without removal of the intravenous device. Exciting developments in catheter impregnation with antibiotics as well as nanoscale surface design promise innovative changes in the way that physicians manage intravenous catheters. Occlusion of a catheter renders the catheter unusable and is often treated by tissue plasminogen activator administration or replacement of the line. Prevention of this complication requires a thorough understanding of the mechanisms of platelet aggregation, signaling and cross-linking. This article will look at the advances in biomaterial design specifically drug eluting, non-drug eluting, lubricious coatings and micropatterning as well as some of the characteristics of each as they relate to CVCs.
Guide Catheter Extension Device Is Effective in Renal Angioplasty for Severely Calcified Lesions
Sugimoto, Takeshi; Nomura, Tetsuya; Hori, Yusuke; Yoshioka, Kenichi; Kubota, Hiroshi; Miyawaki, Daisuke; Urata, Ryota; Kikai, Masakazu; Keira, Natsuya; Tatsumi, Tetsuya
2017-01-01
Patient: Male, 69 Final Diagnosis: Atherosclerotic renal artery stenosis Symptoms: None Medication: — Clinical Procedure: — Specialty: Radiology Objective: Unusual setting of medical care Background: The GuideLiner catheter extension device is a monorail-type “Child” support catheter that facilitates coaxial alignment with the guide catheter and provides an appropriate back-up force. This device has been developed in the field of coronary intervention, and now is becoming widely applied in the field of endovascular treatment. However, there has been no report on the effectiveness of the guide catheter extension device in percutaneous transluminal renal angioplasty (PTRA). Case Report: We encountered a case of atherosclerotic subtotal occlusion at the ostium of the left renal artery. Due to the severely calcified orifice and weaker back-up force provided by a JR4 guide catheter, we could not pass any guide-wires through the target lesion. Therefore, we introduced a guide catheter extension device, the GuideLiner catheter, through the guide catheter and achieved good guidewire maneuverability. We finally deployed 2 balloon-expandable stents and successfully performed all PTRA procedures. Conclusions: The guide catheter extension device can be effective in PTRA for severely calcified subtotal occlusion. PMID:28533503
Semi-automated location identification of catheters in digital chest radiographs
NASA Astrophysics Data System (ADS)
Keller, Brad M.; Reeves, Anthony P.; Cham, Matthew D.; Henschke, Claudia I.; Yankelevitz, David F.
2007-03-01
Localization of catheter tips is the most common task in intensive care unit imaging. In this work, catheters appearing in digital chest radiographs acquired by portable chest x-rays were tracked using a semi-automatic method. Due to the fact that catheters are synthetic objects, its profile does not vary drastically over its length. Therefore, we use forward looking registration with normalized cross-correlation in order to take advantage of a priori information of the catheter profile. The registration is accomplished with a two-dimensional template representative of the catheter to be tracked generated using two seed points given by the user. To validate catheter tracking with this method, we look at two metrics: accuracy and precision. The algorithms results are compared to a ground truth established by catheter midlines marked by expert radiologists. Using 12 objects of interest comprised of naso-gastric, endo-tracheal tubes, and chest tubes, and PICC and central venous catheters, we find that our algorithm can fully track 75% of the objects of interest, with a average tracking accuracy and precision of 85.0%, 93.6% respectively using the above metrics. Such a technique would be useful for physicians wishing to verify the positioning of catheter tips using chest radiographs.
Fukuoka, Kahoru; Furuichi, Mihoko; Ito, Kenta; Morikawa, Yoshihiko; Watanabe, Ichiro; Shimizu, Naoki; Horikoshi, Yuho
2018-06-13
Catheter-associated urinary tract infections account for 30% of healthcare-associated infections. To date, few studies have addressed pediatric catheter-associated urinary tract infection in PICUs. The aim of our study was to assess the risk of catheter-associated urinary tract infection in relation to the duration of catheterization in the PICU. Retrospective cohort study. PICU at a tertiary children's hospital. Our study was conducted between April 2012 and June 2015 at Tokyo Metropolitan Children's Medical Center in Japan. Children in the PICU with an urethral catheter were included. Catheter-associated urinary tract infection cases were defined according to the National Healthcare Safety Network criteria. The patients' demographic data and isolated organisms were reviewed. Duration of catheterization and the catheter-associated urinary tract infection occurrence rate were analyzed. None. Among 1,890 catheterizations, 23 catheter-associated urinary tract infection cases were identified. The overall occurrence rate was 2.35/1,000 catheter-days. Among the patients with catheter-associated urinary tract infection, 13 were boys. The median age was 11 months (interquartile range, 7-35 mo), and the median duration of catheterization was 7 days (interquartile range, 5-12 d). The isolated bacteria were Escherichia coli (26.5%), Enterococcus faecalis (17.6%), and Klebsiella pneumoniae (11.8%). Two species were isolated in each of 11 cases (47.8%). Each additional day of catheterization increased the risk of catheter-associated urinary tract infection (odds ratio, 1.06; 95% CI, 1.02-1.10, and odds ratio adjusted for contact precaution status and surgical procedures was 1.05; 95% CI, 1.01-1.09). Longer duration of catheterization increased the risk of catheter-associated urinary tract infection by 5% each day at the PICU. Prompt removal of the urethral catheter is strongly recommended whenever feasible.
The role of laparoscopic surgery in the management of a malfunctioning peritoneal catheter.
Alabi, A; Dholakia, S; Ablorsu, E
2014-11-01
Peritoneal catheter malfunction is a common complication of peritoneal dialysis (PD). It has a high failure rate with conservative management. Catheter replacement was historically the standard surgical treatment of choice. Nowadays, laparoscopy has been introduced as an alternative surgical modality to rescue the malfunctioning peritoneal catheter and also offers the possibility of replacement if indicated. The aim of this study was to compare the outcomes of these two surgical modalities. The medical records of consecutive patients who underwent surgical treatment for malfunctioning PD catheters (between January 2010 and April 2013) were analysed. The primary outcome included successful return to adequate PD. The secondary endpoint was length of catheter patency and the cause of catheter failure. A total of 32 cases were identified, of which 8 had open catheter replacement and 24 had a laparoscopic intervention. The overall median follow-up duration was 12.5 months. The success rate for laparoscopic surgery in terms of functioning catheter at 12 months was 62.5% but only 37.5% for open surgery. The mean length of catheter patency after laparoscopic intervention was 31.6 months compared with only 13.6 months for the open surgery group. The most common cause of catheter failure diagnosed during laparoscopic intervention was catheter migration (33.0%), followed by omental wrap and catheter blockage by fibrin/blood plug (25.0% each). Open surgery did not have any diagnostic potential. Laparoscopy is the treatment of choice for malfunctioning PD. Its proven benefit includes simultaneous identification of the aetiological cause of malfunction together with direct correction of this problem, thereby maximising outcome. It also allows for rapid recommencement of PD and avoidance of haemodialysis, saving cost and resources.
Ueda, Yu; Odunayo, Adesola; Mann, F A
2013-01-01
To determine whether heparinized saline would be more effective in maintaining the patency of peripheral IV catheters in dogs compared to 0.9% sodium chloride. Prospective blinded randomized study. University Veterinary Teaching Hospital. Thirty healthy purpose bred dogs, intended for use in the junior surgery laboratory, were utilized. The dogs were randomized into 1 of 3 groups, 2 treatment groups and a control group. An 18-Ga cephalic catheter was placed in the cephalic vein of each dog. Each dog in the treatment group had their catheter flushed with either 10 IU/mL heparinized saline or 0.9% sodium chloride every 6 hours for 42 hours. The dogs in the control group did not have their catheters flushed until the end of the study period. Immediately prior to flushing catheters, each catheter was evaluated for patency by aspiration of blood and the catheter site was evaluated for phlebitis. All dogs in the heparinized saline and 0.9% sodium chloride group had catheters that flushed easily at each evaluation point. More dogs in the saline group had catheters from which blood could not be aspirated, but there was no significant difference between these groups. All dogs in the control group had catheters that flushed easily at the end of the assigned 6 hour interval except in 1 dog. Phlebitis was not detected in any dog. Flushes of 0.9% sodium chloride were found to be as effective as 10 IU/mL heparinized saline flushes in maintaining patency of 18-Ga peripheral venous catheters in dogs for up to 42 hours. For peripheral catheters placed with the intention of performing serial blood draws, heparinized flushes may be warranted. © Veterinary Emergency and Critical Care Society 2013.
Gill, T; Barua, N U; Woolley, M; Bienemann, A S; Johnson, D E; S O'Sullivan; Murray, G; Fennelly, C; Lewis, O; Irving, C; Wyatt, M J; Moore, P; Gill, S S
2013-09-30
The optimisation of convection-enhanced drug delivery (CED) to the brain is fundamentally reliant on minimising drug reflux. The aim of this study was to evaluate the performance of a novel reflux-resistant CED catheter incorporating a recessed-step and to compare its performance to previously described stepped catheters. The in vitro performance of the recessed-step catheter was compared to a conventional "one-step" catheter with a single transition in outer diameter (OD) at the catheter tip, and a "two-step" design comprising two distal transitions in OD. The volumes of distribution and reflux were compared by performing infusions of Trypan blue into agarose gels. The in vivo performance of the recessed-step catheter was then analysed in a large animal model by performing infusions of 0.2% Gadolinium-DTPA in Large White/Landrace pigs. The recessed-step catheter demonstrated significantly higher volumes of distribution than the one-step and two-step catheters (p=0.0001, one-way ANOVA). No reflux was detected until more than 100 ul had been delivered via the recessed-step catheter, whilst reflux was detected after infusion of only 25 ul via the 2 non-recessed catheters. The recessed-step design also showed superior reflux resistance to a conventational one-step catheter in vivo. Reflux-free infusions were achieved in the thalamus, putamen and white matter at a maximum infusion rate of 5 ul/min using the recessed-step design. The novel recessed-step catheter described in this study shows significant potential for the achievement of predictable high volume, high flow rate infusions whilst minimising the risk of reflux. Copyright © 2013 Elsevier B.V. All rights reserved.
Zehnder, Pascal; Roth, Beat; Burkhard, Fiona C; Kessler, Thomas M
2008-09-01
We determined and compared urethral pressure measurements using air charged and microtip catheters in a prospective, single-blind, randomized trial. A consecutive series of 64 women referred for urodynamic investigation underwent sequential urethral pressure measurements using an air charged and a microtip catheter in randomized order. Patients were blinded to the type and sequence of catheter used. Agreement between the 2 catheter systems was assessed using the Bland and Altman 95% limits of agreement method. Intraclass correlation coefficients of air charged and microtip catheters for maximum urethral closure pressure at rest were 0.97 and 0.93, and for functional profile length they were 0.9 and 0.78, respectively. Pearson's correlation coefficients and Lin's concordance coefficients of air charged and microtip catheters were r = 0.82 and rho = 0.79 for maximum urethral closure pressure at rest, and r = 0.73 and rho = 0.7 for functional profile length, respectively. When applying the Bland and Altman method, air charged catheters gave higher readings than microtip catheters for maximum urethral closure pressure at rest (mean difference 7.5 cm H(2)O) and functional profile length (mean difference 1.8 mm). There were wide 95% limits of agreement for differences in maximum urethral closure pressure at rest (-24.1 to 39 cm H(2)O) and functional profile length (-7.7 to 11.3 mm). For urethral pressure measurement the air charged catheter is at least as reliable as the microtip catheter and it generally gives higher readings. However, air charged and microtip catheters cannot be used interchangeably for clinical purposes because of insufficient agreement. Hence, clinicians should be aware that air charged and microtip catheters may yield completely different results, and these differences should be acknowledged during clinical decision making.
Prasad, Sandip M; Large, Michael C; Patel, Amit R; Famakinwa, Olufenwa; Galocy, R Matthew; Karrison, Theodore; Shalhav, Arieh L; Zagaja, Gregory P
2014-07-01
Retrospective single institution data suggest that postoperative pain after robot-assisted laparoscopic radical prostatectomy is decreased by early removal of the urethral catheter with suprapubic tube drainage. In a randomized patient population we determined whether suprapubic tube drainage with early urethral catheter removal would improve postoperative pain compared with urethral catheter drainage alone. Men with a body mass index of less than 40 kg/m(2) who had newly diagnosed prostate cancer and elected robot-assisted laparoscopic radical prostatectomy were included in analysis. Block randomization by surgeon was used and randomization assignment was done after completing the urethrovesical anastomosis. In patients assigned to suprapubic tube drainage the urethral catheter was removed on postoperative day 1 and all catheters were removed on postoperative day 7. Visual analog pain scale and satisfaction questionnaires were administered on postoperative days 0, 1 and 7. A total of 29 patients were randomized to the urethral catheter vs 29 to the suprapubic tube plus early urethral catheter removal at the time of interim futility analysis. Mean visual analog pain scale scores did not differ between the groups at any time point and a similar percent of patients cited the catheter as the greatest bother with nonsignificant differences in treatment related satisfaction. Complications during postoperative week 1 did not vary between the groups. Based on interim results the trial was terminated due to lack of effect. Patients randomized to suprapubic tube vs urethral catheter drainage for the week after prostatectomy had similar pain, catheter related bother and treatment related satisfaction in the perioperative period. We no longer routinely offer suprapubic tube drainage with early urethral catheter removal at our institution. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Mid-term outcome of endovascular treatment for acute lower extremity deep venous thrombosis.
Jiang, Kun; Li, Xiao-Qiang; Sang, Hong-Fei; Qian, Ai-Min; Rong, Jian-Jie; Li, Cheng-Long
2017-04-01
Purposes of the study To evaluate the benefit of stenting the iliac vein in patients with residual iliac vein stenosis treated with catheter-directed thrombolysis for acute iliofemoral deep venous thrombosis. Procedures In this randomized prospective study, patients with a first-time acute lower extremity deep venous thrombosis that had persisted <14 days were treated with catheter-directed thrombolysis. After catheter-directed thrombolysis, patients with >50% residual iliac vein stenosis were randomly divided into two groups: catheter-directed thrombolysis + Stent Group and catheter-directed thrombolysis Alone Group. Patients received urokinase thrombolysis and low-molecular-weight heparin/oral warfarin during the hospitalization period and were administrated oral warfarin after discharge. Cumulative deep vein patency, the Clinical Etiology Anatomic Pathophysiologic classification system, the Venous Clinical Severity Score and the Chronic Venous Insufficiency Questionnaire score were evaluated. Findings The cumulative deep vein patency rate was 74.07% in the catheter-directed thrombolysis + Stent Group and 46.59% in the catheter-directed thrombolysis Alone Group. The mean postoperative Clinical Etiology Anatomic Pathophysiologic classification and Venous Clinical Severity Score was significantly lower in the catheter-directed thrombolysis + Stent Group than in the catheter-directed thrombolysis Alone Group. The mean postoperative Chronic Venous Insufficiency Questionnaire score was significantly higher in the catheter-directed thrombolysis + Stent Group than the catheter-directed thrombolysis Alone Group. Conclusions Placement of an iliac vein stent in patients with residual iliac vein stenosis after catheter-directed thrombolysis for acute lower extremity deep venous thrombosis increases iliac vein patency and improves clinical symptoms and health-related quality of life at mid-term follow-up compared to patients treated with catheter-directed thrombolysis alone.
Davis, Niall F.; McMahon, Barry P.; Walsh, Michael; McDermott, Thomas E.D.; Thornhill, John A.; Manecksha, Rustom P.
2017-01-01
Introduction We aimed to investigate irrigation and drainage characteristics of commercially available urethral catheters and determined which catheter offers the best flow characteristics. Material and methods Twelve different commercially available urethral catheters from three companies (Bard™, Rusch™ and Dover™) were investigated to compare their irrigation and drainage properties. Irrigation port, drainage port and overall cross-sectional areas for a 24Fr 3-way catheter was measured and compared. The maximum (Qmax) and average (Qavg) irrigation and drainage flow rates for each catheter was measured for 20–40 seconds using uroflowmetry. The primary endpoint was to determine which catheter offers optimal irrigation and drainage parameters. Results Overall cross-sectional area, irrigation port cross-sectional area, and drainage port cross-sectional area differed significantly for each 24Fr 3-way catheter assessed (p <0.001). The 24Fr 3-way Rusch Simplastic™ catheter consistently demonstrated the greatest maximal flow rate (Qmax: 5 ±0.3 ml/s) and average flow rate (Qavg: 4.6 ±0.2 ml/s) for irrigation. The 24Fr 3-way Dover™ catheter provided the greatest drainage properties (Qmax: 19.7 ±2 ml/s; Q avg: 15.9 ±5 ml/s). In the setting of continuous bladder irrigation, the 24Fr 3-way Rusch Simplastic™ catheter provided the highest irrigation rates (Qmax: 6.6 ±1.8 ml/s; Q avg: 4.6 ±0.9 ml/s). Conclusions Three-way catheters demonstrate significant differences in their irrigation and drainage characteristics. The type of catheter selected should be based on the appropriate prioritization of efficient bladder irrigation versus efficient bladder drainage. PMID:29410890
Arnau, Antonio
2008-01-01
From the first applications of AT-cut quartz crystals as sensors in solutions more than 20 years ago, the so-called quartz crystal microbalance (QCM) sensor is becoming into a good alternative analytical method in a great deal of applications such as biosensors, analysis of biomolecular interactions, study of bacterial adhesion at specific interfaces, pathogen and microorganism detection, study of polymer film-biomolecule or cell-substrate interactions, immunosensors and an extensive use in fluids and polymer characterization and electrochemical applications among others. The appropriate evaluation of this analytical method requires recognizing the different steps involved and to be conscious of their importance and limitations. The first step involved in a QCM system is the accurate and appropriate characterization of the sensor in relation to the specific application. The use of the piezoelectric sensor in contact with solutions strongly affects its behavior and appropriate electronic interfaces must be used for an adequate sensor characterization. Systems based on different principles and techniques have been implemented during the last 25 years. The interface selection for the specific application is important and its limitations must be known to be conscious of its suitability, and for avoiding the possible error propagation in the interpretation of results. This article presents a comprehensive overview of the different techniques used for AT-cut quartz crystal microbalance in in-solution applications, which are based on the following principles: network or impedance analyzers, decay methods, oscillators and lock-in techniques. The electronic interfaces based on oscillators and phase-locked techniques are treated in detail, with the description of different configurations, since these techniques are the most used in applications for detection of analytes in solutions, and in those where a fast sensor response is necessary. PMID:27879713
Chinnadurai, Ponraj; Duran, Cassidy; Al-Jabbari, Odeaa; Abu Saleh, Walid K; Lumsden, Alan; Bismuth, Jean
2016-01-01
To report our initial experience and highlight the value of using intraoperative C-arm cone beam computed tomography (CT; DynaCT(®)) image fusion guidance along with steerable robotic endovascular catheter navigation to optimize vessel cannulation. Between May 2013 and January 2015, all patients who underwent endovascular procedures using DynaCT image fusion technique along with Hansen Magellan vascular robotic catheter were included in this study. As a part of preoperative planning, relevant vessel landmarks were electronically marked in contrast-enhanced multi-slice computed tomography images and stored. At the beginning of procedure, an intraoperative noncontrast C-arm cone beam CT (syngo DynaCT(®), Siemens Medical Solutions USA Inc.) was acquired in the hybrid suite. Preoperative images were then coregistered to intraoperative DynaCT images using aortic wall calcifications and bone landmarks. Stored landmarks were then overlaid on 2-dimensional (2D) live fluoroscopic images as virtual markers that are updated in real-time with C-arm, table movements and image zoom. Vascular access and robotic catheter (Magellan(®), Hansen Medical) was setup per standard. Vessel cannulation was performed based on electronic virtual markers on live fluoroscopy using robotic catheter. The impact of 3-dimensional (3D) image fusion guidance on robotic vessel cannulation was evaluated retrospectively, by assessing quantitative parameters like number of angiograms acquired before vessel cannulation and qualitative parameters like accuracy of vessel ostium and centerline markers. All 17 vessels were cannulated successfully in 14 patients' attempted using robotic catheter and image fusion guidance. Median vessel diameter at origin was 5.4 mm (range, 2.3-13 mm), whereas 12 of 17 (70.6%) vessels had either calcified and/or stenosed origin from parent vessel. Nine of 17 vessels (52.9 %) were cannulated without any contrast injection. Median number of angiograms required before cannulation was 0 (range, 0-2). On qualitative assessment, 14 of 15 vessels (93.3%) had grade = 1 accuracy (guidewire inside virtual ostial marker). Fourteen of 14 vessels had grade = 1 accuracy (virtual centerlines that matched with the actual vessel trajectory during cannulation). In this small series, the experience of using DynaCT image fusion guidance together with a steerable endovascular robotic catheter indicates that such image fusion strategies can enhance intraoperative 2D fluoroscopy by bringing preoperative 3D information about vascular stenosis and/or calcification, angulation, and take off from main vessel thereby facilitating ultimate vessel cannulation. Copyright © 2016 Elsevier Inc. All rights reserved.
Central venous catheter integrity during mechanical power injection of iodinated contrast medium.
Macha, Douglas B; Nelson, Rendon C; Howle, Laurens E; Hollingsworth, John W; Schindera, Sebastian T
2009-12-01
To evaluate a widely used nontunneled triple-lumen central venous catheter in order to determine whether the largest of the three lumina (16 gauge) can tolerate high flow rates, such as those required for computed tomographic angiography. Forty-two catheters were tested in vitro, including 10 new and 32 used catheters (median indwelling time, 5 days). Injection pressures were continuously monitored at the site of the 16-gauge central venous catheter hub. Catheters were injected with 300 and 370 mg of iodine per milliliter of iopamidol by using a mechanical injector at increasing flow rates until the catheter failed. The infusion rate, hub pressure, and location were documented for each failure event. The catheter pressures generated during hand injection by five operators were also analyzed. Mean flow rates and pressures at failure were compared by means of two-tailed Student t test, with differences considered significant at P < .05. Injections of iopamidol with 370 mg of iodine per milliliter generate more pressure than injections of iopamidol with 300 mg of iodine per milliliter at the same injection rate. All catheters failed in the tubing external to the patient. The lowest flow rate at which catheter failure occurred was 9 mL/sec. The lowest hub pressure at failure was 262 pounds per square inch gauge (psig) for new and 213 psig for used catheters. Hand injection of iopamidol with 300 mg of iodine per milliliter generated peak hub pressures ranging from 35 to 72 psig, corresponding to flow rates ranging from 2.5 to 5.0 mL/sec. Indwelling use has an effect on catheter material property, but even for used catheters there is a substantial safety margin for power injection with the particular triple-lumen central venous catheter tested in this study, as the manufacturer's recommendation for maximum pressure is 15 psig.
Multifunctional catheters combining intracardiac ultrasound imaging and electrophysiology sensing.
Stephens, D N; Cannata, J; Liu, Ruibin; Zhao, Jian Zhong; Shung, K K; Nguyen, Hien; Chia, R; Dentinger, A; Wildes, D; Thomenius, K E; Mahajan, A; Shivkumar, K; Kim, Kang; O'Donnell, M; Nikoozadeh, A; Oralkan, O; Khuri-Yakub, P T; Sahn, D J
2008-07-01
A family of 3 multifunctional intracardiac imaging and electrophysiology (EP) mapping catheters has been in development to help guide diagnostic and therapeutic intracardiac EP procedures. The catheter tip on the first device includes a 7.5 MHz, 64-element, side-looking phased array for high resolution sector scanning. The second device is a forward-looking catheter with a 24-element 14 MHz phased array. Both of these catheters operate on a commercial imaging system with standard software. Multiple EP mapping sensors were mounted as ring electrodes near the arrays for electrocardiographic synchronization of ultrasound images and used for unique integration with EP mapping technologies. To help establish the catheters' ability for integration with EP interventional procedures, tests were performed in vivo in a porcine animal model to demonstrate both useful intracardiac echocardiographic (ICE) visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheters also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. The companion paper of this work discusses the catheter design of the side-looking catheter with special attention to acoustic lens design. The third device in development is a 10 MHz forward-looking ring array that is to be mounted at the distal tip of a 9F catheter to permit use of the available catheter lumen for adjunctive therapy tools.
Griffiths, Robert I.; Newsome, Britt B.; Leung, Grace; Block, Geoffrey A.; Herbert, Robert J.; Danese, Mark D.
2012-01-01
Practice guidelines define hemodialysis catheter dysfunction as blood flow rate (BFR) <300 mL/min. We conducted a study using data from DaVita and the United States Renal Data System to evaluate the impact of catheter dysfunction on dialysis and other medical services. Patients were included if they had ≥8 consecutive weeks of catheter dialysis between 8/2004 and 12/2006. Actual BFR <300 mL/min despite planned BFR ≥300 mL/min was used to define catheter dysfunction during each dialysis session. Among 9,707 patients, the average age was 62,53% were female, and 40% were black. The median duration of catheter dialysis was 190 days, and the cohort accounted for 1,075,701 catheter dialysis sessions. There were 70,361 sessions with catheter dysfunction, and 6,33 1 (65.2%) patients had at least one session with catheter dysfunction. In multivariate repeated measures analysis, catheter dysfunction was associated with increased odds of missing a dialysis session due to access problems (Odds ratio [OR] 2.50; P < 0.001), having an access-related procedure (OR 2.10; P < 0.001), and being hospitalized (OR 1.10; P = 0.001). Catheter dysfunction defined according to NKF vascular access guidelines results in disruptions of dialysis treatment and increased use of other medical services. PMID:22518313
Discriminating Tissue Stiffness with a Haptic Catheter: Feeling the Inside of the Beating Heart
Kesner, Samuel B.; Howe, Robert D.
2011-01-01
Catheter devices allow physicians to access the inside of the human body easily and painlessly through natural orifices and vessels. Although catheters allow for the delivery of fluids and drugs, the deployment of devices, and the acquisition of the measurements, they do not allow clinicians to assess the physical properties of tissue inside the body due to the tissue motion and transmission limitations of the catheter devices, including compliance, friction, and backlash. The goal of this research is to increase the tactile information available to physicians during catheter procedures by providing haptic feedback during palpation procedures. To accomplish this goal, we have developed the first motion compensated actuated catheter system that enables haptic perception of fast moving tissue structures. The actuated catheter is instrumented with a distal tip force sensor and a force feedback interface that allows users to adjust the position of the catheter while experiencing the forces on the catheter tip. The efficacy of this device and interface is evaluated through a psychophyisical study comparing how accurately users can differentiate various materials attached to a cardiac motion simulator using the haptic device and a conventional manual catheter. The results demonstrate that haptics improves a user's ability to differentiate material properties and decreases the total number of errors by 50% over the manual catheter system. PMID:25285321
Modified laparoscopic placement of peritoneal dialysis catheter with intra-abdominal fixation.
Shen, Quanquan; Jiang, Xinxin; Shen, Xiaogang; Yu, Fangyan; Tu, Qiudi; Chen, Wangfang; Ye, Qing; Behera, Tapas Ranjan; He, Qiang
2017-08-01
Peritoneal dialysis (PD) is a commonly accepted method of treating end-stage renal disease (ESRD). Various laparoscopic techniques for the placement of PD catheter have been described. In this study, we developed a novel modified laparoscopic technique for PD catheter placement and evaluated the early results. A straight Tenckhoff PD catheter was placed employing the modified technique in 39 consecutive patients with ESRD from May 2013 to April 2016. The technique is laparoscopically guided intra-abdominal fixation of the PD catheter tip at one point by using suture passer hernia forceps. Individual information including sex, age, primary disease etiology, complications, surgical duration, morbidity, mortality and catheter survival was collected and analyzed. The modified laparoscopic procedure was effectively performed in all patients with a mean operative time of 45 ± 7 min. No conversions from laparoscopy to open surgery of catheter placement occurred. There was one case showing early pericatheter leakage. There were no serious complications, such as bleeding, abdominal wall hernias, distal catheter cuff extrusion and infections of the exit site or tunnel during surgery or the postoperative duration. No mortality was observed in this group of patients. The 6-month follow-up study showed 100% catheter-related complication-free survival. Our modified laparoscopic intra-abdominal fixation technique using suture passer hernia forceps is a simple and safe method for PD catheter placement and is effective in minimizing the risk of catheter migration.
[Persistent neonatal hypoglycaemia caused by arterial positioning of the umbilical venous catheter].
Peters, P A G; Brus, F; Noordam, C; Smorenburg, M K; van Setten, P A
2007-10-06
Two neonates, a girl born at 40 2/7 weeks weighing 4165 g and a boy born at 37 6/7 weeks weighing 4040 g, received umbilical venous catheters to help manage hypoglycaemia. The catheter was ineffective or only effective when high doses of glucose were used, due to what later appeared to be arterial positioning of the catheter. Both patients recovered without consequences. Persistent hypoglycaemia is a common problem in newborns and can cause severe neurological sequelae. A relatively uncommon cause is malpositioning of the umbilical catheter. Positioning in an artery leads to direct infusion of glucose into the pancreas, which causes hyperinsulinaemia and can lead to potentially dangerous nonketotic hypoglycaemia. Arterial positioning of the umbilical catheter should be ruled out at an early stage. Correct catheter positioning can be determined using careful inspection of the umbilical veins, radiological examination of the catheter position, blood gas analysis or vascular pulsation.
Use of monorail PTCA balloon catheter for local drug delivery.
Trehan, Vijay; Nair, Girish M; Gupta, Mohit D
2007-01-01
We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.
Initial experience with the Europass: a new ultra-low profile monorail balloon catheter.
Zimarino, M; Corcos, T; Favereau, X; Tamburino, C; Toussaint, M; Spaulding, C; Guérin, Y
1994-09-01
One of the causes for percutaneous transluminal coronary angioplasty (PTCA) failure is the inability to cross the lesion with the balloon catheter after guidewire positioning. The Europass coronary angioplasty catheter is a monorail Duralyn balloon catheter developed to enhance lesion crossability and to overcome this limitation. This system was evaluated in 50 patients in which target lesions were chronic total coronary occlusions (12 cases) or stenoses that could not be reached or crossed by other new monorail balloon catheters. Overall procedural success was obtained in 49/50 patients (98%), using a single Europass balloon catheter in 46/50 patients (92%), with no in-hospital complications. Its low profile, small distal shaft, and excellent trackability allowed successful angioplasty in cases where other catheters failed. This balloon catheter represents a significant advance in angioplasty technology and can be considered as a first-choice device for a safe and expeditious single-operator procedure.
Kuno, Toshiki; Fujisawa, Taishi; Yamazaki, Hiroyuki; Motoda, Hiroyuki; Kodaira, Masaki; Numasawa, Yohei
2015-01-01
Objective: Percutaneous coronary intervention for anomalous right coronary artery (RCA) originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. Methods: We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. Results: We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. Conclusions: We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin. PMID:27489700
Bilir, Ayten; Yelken, Birgül; Erkan, Ayse
2013-06-01
Protection of the catheter site by antimicrobial agents is one of the most important factors in the prevention of infection. Povidone iodine and chlorhexidine gluconate are the most common used agents for dressing. The purpose of this study was to compare the effects of povidone iodine, chlorhexidine gluconate and octenidine hydrochloride in preventing catheter related infections. Patients were randomized to receive; 4% chlorhexidine gluconate, 10% povidone iodine or octenidine hydrochlorodine for cutaneous antisepsis. Cultures were taken at the site surrounding catheter insertion and at the catheter hub after removal to help identify the source of microorganisms. Catheter related sepsis was 10.5% in the povidone iodine and octenidine hydrochlorodine groups. Catheter related colonization was 26.3% in povidone iodine group and 21.5% in octenidine hydrochlorodine group. 4% chlorhexidine or octenidine hydrochlorodine for cutaneous disinfection before insertion of an intravascular device and for post-insertion site care can reduce the catheter related colonization.
49 CFR 236.337 - Locking faces of mechanical locking; fit.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Locking faces of mechanical locking; fit. 236.337... Rules and Instructions § 236.337 Locking faces of mechanical locking; fit. Locking faces shall fit... face. ...
49 CFR 236.337 - Locking faces of mechanical locking; fit.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Locking faces of mechanical locking; fit. 236.337... Rules and Instructions § 236.337 Locking faces of mechanical locking; fit. Locking faces shall fit... face. ...
49 CFR 236.337 - Locking faces of mechanical locking; fit.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false Locking faces of mechanical locking; fit. 236.337... Rules and Instructions § 236.337 Locking faces of mechanical locking; fit. Locking faces shall fit... face. ...
49 CFR 236.337 - Locking faces of mechanical locking; fit.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false Locking faces of mechanical locking; fit. 236.337... Rules and Instructions § 236.337 Locking faces of mechanical locking; fit. Locking faces shall fit... face. ...
Yu, Xue; Liang, Jiying; Yang, Tiangang; Gong, Mengjie; Xi, Dongman; Liu, Hongyun
2018-01-15
Herein, a resettable and reprogrammable biomolecular keypad lock on the basis of a closed bipolar electrode (BPE) system was established. In this system, one ITO electrode with immobilized chitosan (CS) and glucose oxidase (GOD), designated as CS-GOD, acted as one pole of BPE in the sensing cell; another ITO with electrodeposited Prussian blue (PB) films as the other pole in the reporting cell. The addition of ascorbic acid (AA) in the sensing cell with driving voltage (V tot ) at +2.5V would make the PB films become Prussian white (PW) in the reporting cell, accompanied by the color change from blue to nearly transparent. On the other hand, with the help of oxygen, the addition of glucose in the sensing cell with V tot at -1.5V would induce PW back to PB. The change of color and the corresponding UV-vis absorbance at 700nm for the PB/PW films in the reporting cell could be reversibly switched by changing the solute in the sensing cell between AA and glucose and then switching V tot between +2.5 and -1.5V. Based on these, a keypad lock was developed with AA, glucose and V tot as 3 inputs, and the color change of the PB/PW films as the output. This keypad lock system combined enzymatic catalysis with bipolar electrochemistry, demonstrating some unique advantages such as good reprogrammability, easy resettability and visual readout by naked eye. Copyright © 2017 Elsevier B.V. All rights reserved.
49 CFR 236.330 - Locking dog of switch-and-lock movement.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false Locking dog of switch-and-lock movement. 236.330 Section 236.330 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... Rules and Instructions § 236.330 Locking dog of switch-and-lock movement. Locking dog of switch-and-lock...
49 CFR 236.330 - Locking dog of switch-and-lock movement.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false Locking dog of switch-and-lock movement. 236.330 Section 236.330 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... Rules and Instructions § 236.330 Locking dog of switch-and-lock movement. Locking dog of switch-and-lock...
49 CFR 236.330 - Locking dog of switch-and-lock movement.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Locking dog of switch-and-lock movement. 236.330 Section 236.330 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... Rules and Instructions § 236.330 Locking dog of switch-and-lock movement. Locking dog of switch-and-lock...
49 CFR 236.330 - Locking dog of switch-and-lock movement.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Locking dog of switch-and-lock movement. 236.330 Section 236.330 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... Rules and Instructions § 236.330 Locking dog of switch-and-lock movement. Locking dog of switch-and-lock...
49 CFR 236.330 - Locking dog of switch-and-lock movement.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Locking dog of switch-and-lock movement. 236.330 Section 236.330 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... Rules and Instructions § 236.330 Locking dog of switch-and-lock movement. Locking dog of switch-and-lock...
Cronier, P; Frin, J-M; Steiger, V; Bigorre, N; Talha, A
2013-06-01
Tarsal navicular fractures are rare and treatment of comminuted fractures is especially difficult. Since 2007, the authors have had access to 3D reconstruction from CT scan images and specific locking plates, and they decided to evaluate whether these elements improved management of these severe cases. Between 2007 and 2011, 10 comminuted tarsal navicular fractures were treated in a prospective study. All of the fractures were evaluated by 3D reconstruction from CT scan images, with suppression of the posterior tarsal bones. The surgical approach was chosen according to the type of lesion. Reduction was achieved with a mini-distractor when necessary, and stabilized by AO locking plate fixation (Synthes™). Patient follow-up included a clinical and radiological evaluation (Maryland Foot score, AOFAS score). Eight patients underwent postoperative CT scan. All patients were followed up after a mean 20.5 months. Union was obtained in all patients and arthrodesis was not necessary in any of them. The mean Maryland Foot score was 92.8/100, and the AOFAS score 90.6/100. One patient with an associated comminuted calcaneal fracture had minimal sequella from a compartment syndrome of the foot. The authors did not find any series in the literature that reported evaluating tarsal navicular fractures by 3D reconstruction from CT scan images. The images obtained after suppression of the posterior tarsal bones systematically showed a lateral plantar fragment attached to the plantar calcaneonavicular ligament, which is essential for stability, and which helped determine the reduction technique. Locking plate fixation of these fractures has never been reported. Comminuted fractures of the tarsal navicular were successfully treated with specific imaging techniques in particular 3D reconstructions of CT scan images to choose the surgical approach and the reduction technique. Locking plate fixation of the navicular seems to be a satisfactory solution for the treatment of these particularly difficult fractures. Level IV. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Smith, Sean G; Griffith, Boyce E; Zaharoff, David A
2018-04-05
Ailments of the bladder are often treated via intravesical delivery-direct application of therapeutic into the bladder through a catheter. This technique is employed hundreds of thousands of times every year, but protocol development has largely been limited to empirical determination. Furthermore, the numerical analyses of intravesical delivery performed to date have been restricted to static geometries and have not accounted for bladder deformation. This study uses a finite element analysis approach with biphasic solute transport to investigate several parameters pertinent to intravesical delivery including solute concentration, solute transport properties and instillation volume. The volume of instillation was found to have a substantial impact on the exposure of solute to the deeper muscle layers of the bladder, which are typically more difficult to reach. Indeed, increasing the instillation volume from 50-100 ml raised the muscle solute exposure as a percentage of overall bladder exposure from 60-70% with higher levels achieved for larger instillation volumes. Similar increases were not seen for changes in solute concentration or solute transport properties. These results indicate the role that instillation volume may play in targeting particular layers of the bladder during an intravesical delivery.
Endoscopic-Assisted Burr Hole Reservoir and Ventricle Catheter Placement.
Antes, Sebastian; Tschan, Christoph A; Heckelmann, Michael; Salah, Mohamed; Senger, Sebastian; Linsler, Stefan; Oertel, Joachim
2017-05-01
Accurate positioning of a ventricle catheter is of utmost importance. Various techniques to ensure optimal positioning have been described. Commonly, after catheter placement, additional manipulation is necessary to connect a burr hole reservoir or shunt components. This manipulation can lead to accidental catheter dislocation and should be avoided. Here, we present a new technique that allows direct endoscopic insertion of a burr hole reservoir with an already mounted ventricle catheter. Before insertion, the ventricle catheter was slit at the tip, shortened to the correct length, and connected to the special burr hole reservoir. An intracatheter endoscope was then advanced through the reservoir and the connected catheter. This assemblage allowed using the endoscope as a stylet for shielded ventricular puncture. To confirm correct placement of the ventricle catheter, the endoscope was protruded a few millimeters beyond the catheter tip for inspection. The new technique was applied in 12 procedures. The modified burr hole reservoir was inserted for first-time ventriculoperitoneal shunting (n = 1), cerebrospinal fluid withdrawals and drug administration (n = 2), or different stenting procedures (n = 9). Optimal positioning of the catheter was achieved in 11 of 12 cases. No subcutaneous cerebrospinal fluid collection or fluid leakage through the wound occurred. No parenchymal damage or bleeding appeared. The use of the intracatheter endoscope combined with the modified burr hole reservoir provides a sufficient technique for accurate and safe placement. Connecting the ventricle catheter to the reservoir before the insertion reduces later manipulation and accidental dislocation of the catheter. Copyright © 2017 Elsevier Inc. All rights reserved.
Intrapericardial echocardiography: a novel catheter-based approach to cardiac imaging.
Rodrigues, Ana Clara Tude; d'Avila, Andre; Houghtaling, Christopher; Ruskin, Jeremy N; Picard, Michael; Reddy, Vivek Y
2004-03-01
Transvascular catheter-based intracardiac echocardiography has been successfully used to help guide catheter ablation and electrophysiologic procedures. It has recently been demonstrated that catheters can be safely placed into the pericardial space to allow for epicardial cardiac mapping and ablation. We evaluated the feasibility of catheter-based intrapericardial echocardiography (IPE) during such procedures to identify cardiac structures and visualize intracardiac catheters. IPE was performed in 7 goats by placing a phased-array ultrasound transducer contained within a 10F steerable catheter into the pericardial space using the same transthoracic subxyphoid approach as used to map and ablate epicardial ventricular tachycardia. Images were obtained of cardiac structures and of intracardiac ablation catheters. After the procedure, the hearts were harvested to assess for possible IPE-related lesions. The IPE catheter could be easily placed inside the pericardial space in all animals. In 7 of 7 cases, longitudinal and short-axis views of right- and left-sided chambers and valves were obtained, similar in orientation to transesophageal echocardiography. Visualization of atrial appendages (6/7), pulmonary veins (6/7), coronary arteries (6/7), and coronary sinus (3/6) was also feasible. Assessment of intracardiac transvalvar and venous blood flow was achieved by spectral and color Doppler. The ablation catheter could be clearly visualized inside cardiac chambers. No arrhythmias were induced with IPE catheter manipulation. After harvesting the hearts, no lesions resulting from the procedure were observed. In this experimental setting, IPE was able to provide detailed images of cardiac structures and establish the relative position of the ablation catheter.
Short-term infection in cuffed versus noncuffed small bore central catheters: a randomized trial.
Trerotola, Scott O; Patel, Aalpen A; Shlansky-Goldberg, Richard D; Solomon, Jeffrey A; Mondschein, Jeffrey I; Stavropoulos, S William; Soulen, Michael C; Itkin, Maxim; Chittams, Jesse
2010-02-01
To determine if a polyester cuff offered benefit in jugular small-bore central catheters (SBCCs). Eighty-four patients were randomly assigned to receive a 5-F single- or 6-F dual-lumen SBCC with (n = 42) or without (n = 42) a polyester cuff. Follow-up was performed at 2 weeks, 1 month, and 3 months or at catheter removal, whichever came first. At scheduled follow-up, catheter function, patient satisfaction, and infection were determined. At catheter removal, tip culture was performed to determine colonization and jugular vein patency was determined with ultrasonography (US). The overall infection rate was 0.4 per 1,000 catheter days. There was one clinical infection (noncuffed catheter). Colonization occurred in two noncuffed catheters and one cuffed catheter. There was one catheter dislodgment in the noncuffed group and none in the cuffed group. Cuffed catheters were no more difficult to insert but took slightly longer to remove (6 minutes +/- 4.7 vs 5 minutes +/- 3, P = .39) and often required local anesthesia for removal, whereas noncuffed catheters did not (41% vs 0%, P = .001). Partial (two cuffed, 0 noncuffed) or complete (two cuffed, one noncuffed) jugular thrombosis was seen on five of 58 completion US studies (8.6%). A polyester cuff on a SBCC confers no significant benefit in short-term colonization rates. Infection in SBCCs is uncommon. Despite their small diameters, SBCCs can result in jugular thrombosis, an important consideration in any patient requiring long-term venous access. Copyright (c) 2010 SIR. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Too, Chow Wei, E-mail: toochowwei@gmail.com; Sayani, Raza; Lim, Elvin Yuan Ting
PurposeTo describe a technique involving REcanalisation and Balloon-Oriented puncture for Re-insertion of dialysis catheter in Nonpatent central veins (REBORN) and to report long-term results.Materials and MethodsThis is a retrospective study of ten subjects in whom dialysis catheters were inserted using the REBORN technique from March 2012 to October 2014 and followed up till April 2016. Data on the duration of catheter usage, complications and reasons for removal were obtained. Seven patients had partially occluded lower internal jugular veins (IJV) recanalised in an antegrade fashion via a more cranial puncture. The balloon was then inflated at usual puncture site with anmore » 18G needle. The collapsed balloon was cannulated with a guide wire, and both balloon and guide wire were advanced together into the superior vena cava. This was followed by tunnelled catheter placement using standard techniques. Two patients had catheters placed in the subclavian vein using a similar antegrade technique, and one patient had catheter placed via the left IJV following retrograde recanalisation from a right femoral puncture.ResultsMean duration of catheter use was 278 days (range 32–503). Three catheters were removed due to matured arteriovenous accesses. Four patients had successful catheter change over the same subcutaneous track due to catheter malfunction. One catheter was removed after 7 months because of sepsis. No complications were reported.ConclusionThe REBORN technique allows for the preservation of central veins for future haemodialysis access, which can be challenging in patients requiring long-term dialysis.« less
Comparison of air-charged and water-filled urodynamic pressure measurement catheters.
Cooper, M A; Fletter, P C; Zaszczurynski, P J; Damaser, M S
2011-03-01
Catheter systems are utilized to measure pressure for diagnosis of voiding dysfunction. In a clinical setting, patient movement and urodynamic pumps introduce hydrostatic and motion artifacts into measurements. Therefore, complete characterization of a catheter system includes its response to artifacts as well its frequency response. The objective of this study was to compare the response of two disposable clinical catheter systems: water-filled and air-charged, to controlled pressure signals to assess their similarities and differences in pressure transduction. We characterized frequency response using a transient step test, which exposed the catheters to a sudden change in pressure; and a sinusoidal frequency sweep test, which exposed the catheters to a sinusoidal pressure wave from 1 to 30 Hz. The response of the catheters to motion artifacts was tested using a vortex and the response to hydrostatic pressure changes was tested by moving the catheter tips to calibrated heights. Water-filled catheters acted as an underdamped system, resonating at 10.13 ± 1.03 Hz and attenuating signals at frequencies higher than 19 Hz. They demonstrated significant motion and hydrostatic artifacts. Air-charged catheters acted as an overdamped system and attenuated signals at frequencies higher than 3.02 ± 0.13 Hz. They demonstrated significantly less motion and hydrostatic artifacts than water-filled catheters. The transient step and frequency sweep tests gave comparable results. Air-charged and water-filled catheters respond to pressure changes in dramatically different ways. Knowledge of the characteristics of the pressure-measuring system is essential to finding the best match for a specific application. Copyright © 2011 Wiley-Liss, Inc.
Performance evaluation of a robot-assisted catheter operating system with haptic feedback.
Song, Yu; Guo, Shuxiang; Yin, Xuanchun; Zhang, Linshuai; Hirata, Hideyuki; Ishihara, Hidenori; Tamiya, Takashi
2018-06-20
In this paper, a novel robot-assisted catheter operating system (RCOS) has been proposed as a method to reduce physical stress and X-ray exposure time to physicians during endovascular procedures. The unique design of this system allows the physician to apply conventional bedside catheterization skills (advance, retreat and rotate) to an input catheter, which is placed at the master side to control another patient catheter placed at the slave side. For this purpose, a magnetorheological (MR) fluids-based master haptic interface has been developed to measure the axial and radial motions of an input catheter, as well as to provide the haptic feedback to the physician during the operation. In order to achieve a quick response of the haptic force in the master haptic interface, a hall sensor-based closed-loop control strategy is employed. In slave side, a catheter manipulator is presented to deliver the patient catheter, according to position commands received from the master haptic interface. The contact forces between the patient catheter and blood vessel system can be measured by designed force sensor unit of catheter manipulator. Four levels of haptic force are provided to make the operator aware of the resistance encountered by the patient catheter during the insertion procedure. The catheter manipulator was evaluated for precision positioning. The time lag from the sensed motion to replicated motion is tested. To verify the efficacy of the proposed haptic feedback method, the evaluation experiments in vitro are carried out. The results demonstrate that the proposed system has the ability to enable decreasing the contact forces between the catheter and vasculature.
Radiological Tenckhoff catheter insertion for peritoneal dialysis: A cost-effective approach.
Lee, James; Mott, Nigel; Mahmood, Usman; Clouston, John; Summers, Kara; Nicholas, Pauline; Gois, Pedro Henrique França; Ranganathan, Dwarakanathan
2018-04-01
Radiological insertion of Tenckhoff catheters can be an alternative option for peritoneal dialysis access creation, as compared to surgical catheter insertion. This study will review the outcomes and complications of radiological Tenckhoff catheter insertion in a metropolitan renal service and compare costs between surgical and radiological insertion. Data were collected prospectively for all patients who had a Tenckhoff catheter insertion for peritoneal dialysis (PD) under radiological guidance at our hospital from May 2014 to November 2016. The type of catheter used and complications, including peri-catheter leak, exit site infection and peritonitis were reviewed. Follow-up data were also collected at points 3, 6 and 12 months from catheter insertion. Costing data were obtained from Queensland Health Electronic Reporting System (QHERS) data, average staff salaries and consumable contract price lists. In the 30-month evaluation period, 70 catheters were inserted. Two patients had an unsuccessful procedure due to the presence of abdominal adhesions. Seven patients had an episode of peri-catheter leak, and four patients had an exit site infection following catheter insertion. Peritonitis was observed in nine patients during the study period. The majority of patients (90%) remained on peritoneal dialysis at 3-month follow-up. The average costs of surgical and radiological insertion were noted to be AUD$7788.34 and AUD$1597.35, respectively. Radiological Tenckhoff catheter insertion for peritoneal dialysis appears to be an attractive and cost-effective option given less waiting periods for the procedure, the relatively low cost of insertion and comparable rates of complications. © 2017 The Royal Australian and New Zealand College of Radiologists.
41. LOCK AND DAM NO. 26 (REPLACEMENT). LOCK LOCK ...
41. LOCK AND DAM NO. 26 (REPLACEMENT). LOCK -- LOCK GATES -- LIFT GATE, GATE LEAVES -- GENERAL ASSEMBLY. M-L 26(R) 21/28 - Upper Mississippi River 9-Foot Channel Project, Lock & Dam 26R, Alton, Madison County, IL
A qualitative study exploring the value of a catheter passport.
Jaeger, Melanie De; Fox, Fiona; Cooney, Geraldine; Robinson, Jacqueline
2017-08-10
Many patients leaving hospital with a catheter do not have sufficient information to self-care and can experience physical and psychological difficulties. This study aimed to explore how a patient-held catheter passport affects the experiences of patients leaving hospital with a urethral catheter, the hospital nurses who discharge them and the community nurses who provide ongoing care for them. Qualitative methods used included interviews, focus groups and questionnaires, and thematic analysis. Three major themes were reported-informing patients, informing nurses; improving catheter care, promoting self-management; and supporting transition. The catheter passport can bridge the existing information gap, improve care, promote self-care and help patients adjust to their catheter, especially if complemented by ongoing input from a nurse or other health professional.
[The role of the uretral catheter in the development of catheter- related urinary tract infection].
Vasilyev, A O; Govorov, A V; Shiryaev, A A; Pushkar, D Yu
2017-12-01
The most common source of nosocomial infection is the urinary tract, especially if they it is drained with a urethral catheter. Catheter-associated urinary tract infections account for at least 80% of all complicated urinary tract infections and are the most common type of hospital-acquired infection. Intestinal microflora plays the leading role in the pathogenesis of catheter-associated urinary tract infections, whereas the most important risk factor for their development is the long duration of urinary catheter drainage. In the case of short-term and intermittent catheterization, routine antibiotic prophylaxis is not required, but if a patient develops clinically significant infection, antibiotic therapy is required followed by definitive therapy based on culture. Urethral catheters coated with antimicrobial substances and anti-inflammatory agents can significantly reduce the adhesion and migration of bacteria, thereby reducing the incidence of urinary tract infections. Despite this, the incidence of catheter-associated infection remains high. We have reviewed recent literature related to catheter-associated urinary tract infections and the best means of preventing this condition.
Prevention of catheter-related blood stream infection.
Byrnes, Matthew C; Coopersmith, Craig M
2007-08-01
Catheter-related blood stream infections are a morbid complication of central venous catheters. This review will highlight a comprehensive approach demonstrated to prevent catheter-related blood stream infections. Elements of prevention important to inserting a central venous catheter include proper hand hygiene, use of full barrier precautions, appropriate skin preparation with 2% chlorhexidine, and using the subclavian vein as the preferred anatomic site. Rigorous attention needs to be given to dressing care, and there should be daily assessment of the need for central venous catheters, with prompt removal as soon as is practicable. Healthcare workers should be educated routinely on methods to prevent catheter-related blood stream infections. If rates remain higher than benchmark levels despite proper bedside practice, antiseptic or antibiotic-impregnated catheters can also prevent infections effectively. A recent program utilizing these practices in 103 ICUs in Michigan resulted in a 66% decrease in infection rates. There is increasing recognition that a comprehensive strategy to prevent catheter-related blood stream infections can prevent most infections, if not all. This suggests that thousands of infections can potentially be averted if the simple practices outlined herein are followed.
A new disposable MEMS-based manometric catheter for in-vivo medical tests
NASA Astrophysics Data System (ADS)
Teng, Ming-Foey; Hariz, Alex J.; Hsu, Hung-Yao
2006-12-01
In this paper we report on the development of a new disposable manometric catheter for diagnosis of functional swallowing disorders. The function of this catheter is to measure the intrabolus and peak pressures occurring along the esophageal tract during the swallowing process. Traditionally, in hospitals the water perfusion technique is used to diagnose the disorder. Current manometric catheters developed elsewhere use a solid-state pressure sensor mounted directly on a thin catheter to measure the pressure changes. Both types of catheters are re-usable due to the high running cost, and this in turn increases the risk of contamination among patients, and creates hygiene problems. We have developed a new disposable manometric catheter which consists of a MEMS-based pressure sensor. Recent laboratory characterizations and hospital in-vivo tests show the new developed low cost disposable catheter prototype capable of measuring pressure ranges of 0 to 100mmHg. The in-vivo tests have also shown the new catheter prototype capable of measuring the peak pressure as well as the intrabolus pressure which is a very important parameter for doctors to carry out the required diagnosis.
49 CFR 236.766 - Locking, movable bridge.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Locking, movable bridge. 236.766 Section 236.766... Locking, movable bridge. The rail locks, bridge locks, bolt locks, circuit controllers, and electric locks used in providing interlocking protection at a movable bridge. ...
49 CFR 236.766 - Locking, movable bridge.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, movable bridge. 236.766 Section 236.766... Locking, movable bridge. The rail locks, bridge locks, bolt locks, circuit controllers, and electric locks used in providing interlocking protection at a movable bridge. ...
49 CFR 236.306 - Facing point lock or switch-and-lock movement.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Facing point lock or switch-and-lock movement. 236... Interlocking Standards § 236.306 Facing point lock or switch-and-lock movement. Facing point lock or switch-and-lock movement shall be provided for mechanically operated switch, movable-point frog, or split-point...
49 CFR 236.306 - Facing point lock or switch-and-lock movement.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Facing point lock or switch-and-lock movement. 236... Interlocking Standards § 236.306 Facing point lock or switch-and-lock movement. Facing point lock or switch-and-lock movement shall be provided for mechanically operated switch, movable-point frog, or split-point...
49 CFR 236.306 - Facing point lock or switch-and-lock movement.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false Facing point lock or switch-and-lock movement. 236... Interlocking Standards § 236.306 Facing point lock or switch-and-lock movement. Facing point lock or switch-and-lock movement shall be provided for mechanically operated switch, movable-point frog, or split-point...
49 CFR 236.306 - Facing point lock or switch-and-lock movement.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false Facing point lock or switch-and-lock movement. 236... Interlocking Standards § 236.306 Facing point lock or switch-and-lock movement. Facing point lock or switch-and-lock movement shall be provided for mechanically operated switch, movable-point frog, or split-point...
49 CFR 236.306 - Facing point lock or switch-and-lock movement.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Facing point lock or switch-and-lock movement. 236... Interlocking Standards § 236.306 Facing point lock or switch-and-lock movement. Facing point lock or switch-and-lock movement shall be provided for mechanically operated switch, movable-point frog, or split-point...
Acute urinary retention: which catheter?
Allardice, J. T.; Standfield, N. J.; Wyatt, A. P.
1988-01-01
There is no scientific data on which is the best method and catheter to use in acute urinary retention in males. We therefore compared the efficiency of a size 12 G latex rubber balloon catheter with a similar calibre but more expensive catheter made of polyvinyl-chloride (PVC). A total of 50 patients was studied and a 100% successful catheterisation rate was recorded at first attempt with both catheters, with no significant complications. The importance of the correct management of acute urinary retention, especially adequate analgesia, is stressed and it is concluded that either catheter is satisfactory. PMID:3207328
[Incidence and risk factors for infections from hemodialysis catheters].
Jean, G
2001-01-01
We report here a revue of hemodialysis catheter-related infections data published since 1985. The reported prevalence of bacteremia is 1 to 20% of catheters, and incidence is 0.72 to 9/1000 catheter-days. Local infection is reported in 6 to 63% of catheters and in 1 to 5/1000 catheter-days. Tunneled catheters and implantables chambers reported less infection rate. The most severe complication is endocarditis (4% rate). Death occurs in 8 to 20% of cases. Reported microbial data show that Staphylococcus aureus (SA) is responsible for most infections ahead of non-aureus Staphylococcus. SA skin colonisation is a risk factor for catheter colonisation and the first step of infection. On the other hand, the host immunity impairment in hemodialysis patients seems a significant risk factor. Iron overload, specially after blood transfusions, older age, diabetes mellitus, low serum albumin level, previous history of bacteremia and immunosuppressive treatment have been frequently involved. Other catheter-related factors are time of use, absence of tunnel and use for parenteral nutrition. Nurses plans, dressing type and frequency, nurses work experience are also important. In spite of recent progress in risk factor understanding, hemodialysis-related infection remains frequent. Multicentre studies are necessary to better evaluated care protocols and new catheter material.
Kim, Won Ho; Hong, Tae Hee; Byun, Joung Hun; Kim, Jong Woo; Kim, Sung Hwan; Moon, Sung Ho; Park, Hyun Oh; Choi, Jun Young; Yang, Jun Ho; Jang, In Seok; Lee, Chung Eun; Yun, Jeong Hee
In refractory cardiogenic shock, veno-arterial extracorporeal membrane oxygenation (ECMO) can be initiated. Although left heart decompression can be accomplished by insertion of a left atrial (LA) or left ventricular (LV) cannula using a percutaneous pigtail catheter, the venting flow rate according to catheter size and ECMO flow rate is unknown. We developed an artificial ECMO circuit. One liter saline bag with its pressure set to 20 mm Hg was connected to ECMO to mimic LV failure. A pigtail catheter was inserted into the 1 L saline bag to simulate LV unloading. For each pigtail catheter size (5-8 Fr) and ECMO flow rate (2.0-4.0 L/min), the moving distance of an air bubble that was injected through a three-way stopcock was measured in the arterial pressure line between the pigtail catheter and ECMO inflow limb. The flow rate was then calculated. We obtained the following equation to estimate the pigtail catheter flow rate.Pigtail vent catheter flow rate (ml/min) = 8×ECMOflow rate(L /min)+9×pigtail catheter size(Fr)- 57This equation would aid in designing of a further study to determine optimal venting flow rate. To achieve optimal venting flow, our equation would enable selection of an adequate catheter size.
2016-01-01
Urinary Foley catheters are utilized for management of hospitalized patients and are associated with high rates of urinary tract infections (UTIs). Nitric oxide (NO) potently inhibits microbial biofilm formation, which is the primary cause of catheter associated UTIs (CAUTIs). Herein, commercial silicone Foley catheters are impregnated via a solvent swelling method with S-nitroso-N-acetyl-D-penicillamine (SNAP), a synthetic NO donor that exhibits long-term NO release and stability when incorporated into low water-uptake polymers. The proposed catheters generate NO surface-fluxes >0.7 × 10–10 mol min–1 cm–2 for over one month under physiological conditions, with minimal SNAP leaching. These biomedical devices are demonstrated to significantly decrease formation of biofilm on the surface of the catheter tubings over 3, 7, and 14 day periods by microbial species (Staphylococcus epidermidis and Proteus mirabilis) commonly causing CAUTIs. Toxicity assessment demonstrates that the SNAP-impregnated catheters are fully biocompatible, as extracts of the catheter tubings score 0 on a 3-point grading scale using an accepted mouse fibroblast cell-line toxicity model. Consequently, SNAP-impregnated silicone Foley catheters can likely provide an efficient strategy to greatly reduce the occurrence of nosocomial CAUTIs. PMID:26462294
Are the measurements of water-filled and air-charged catheters the same in urodynamics?
Digesu, G Alessandro; Derpapas, Alexandros; Robshaw, Penny; Vijaya, Gopalan; Hendricken, Caroline; Khullar, Vik
2014-01-01
The aim of our study was to compare air-charged and water-filled catheters simultaneously in the measurement of the intravesical, abdominal and detrusor pressure during urodynamic investigations. Consecutive women with lower urinary tract symptoms, referred for urodynamics were prospectively studied. Readings of intravesical pressure (p(ves)), abdominal pressure (p(abd)) and detrusor pressure (p(det)), recorded by both the air-charged and water-filled catheters, were displayed simultaneously and compared at the end of filling, on standing, on sitting prior to voiding and at the maximum involuntary detrusor contraction. The signals (pressures) recorded by both types of catheter were compared using the Bland-Altman plot and paired samples t test. Twenty women with a mean age of 49 (range 36-72) were recruited. One patient with normal urodynamics was excluded in view of the poor quality trace. At each of the four comparison points, the air-charged catheters consistently produced higher mean pressures than the water-filled catheters. There were wide variations in the difference between the readings produced by the two types of catheter. Pressures measured using air-charged catheters are not comparable with water-filled catheters and are therefore not interchangeable. Caution must be used when comparing urodynamic parameters using air-charged and water-filled catheters.
Borri, Simone; Siciliani de Cumis, Mario; Insero, Giacomo; Bartalini, Saverio; Cancio Pastor, Pablo; Mazzotti, Davide; Galli, Iacopo; Giusfredi, Giovanni; Santambrogio, Gabriele; Savchenkov, Anatoliy; Eliyahu, Danny; Ilchenko, Vladimir; Akikusa, Naota; Matsko, Andrey; Maleki, Lute; De Natale, Paolo
2016-02-17
The need for highly performing and stable methods for mid-IR molecular sensing and metrology pushes towards the development of more and more compact and robust systems. Among the innovative solutions aimed at answering the need for stable mid-IR references are crystalline microresonators, which have recently shown excellent capabilities for frequency stabilization and linewidth narrowing of quantum cascade lasers with compact setups. In this work, we report on the first system for mid-IR high-resolution spectroscopy based on a quantum cascade laser locked to a CaF₂ microresonator. Electronic locking narrows the laser linewidth by one order of magnitude and guarantees good stability over long timescales, allowing, at the same time, an easy way for finely tuning the laser frequency over the molecular absorption line. Improvements in terms of resolution and frequency stability of the source are demonstrated by direct sub-Doppler recording of a molecular line.
Hopf bifurcation and chaos in a third-order phase-locked loop
NASA Astrophysics Data System (ADS)
Piqueira, José Roberto C.
2017-01-01
Phase-locked loops (PLLs) are devices able to recover time signals in several engineering applications. The literature regarding their dynamical behavior is vast, specifically considering that the process of synchronization between the input signal, coming from a remote source, and the PLL local oscillation is robust. For high-frequency applications it is usual to increase the PLL order by increasing the order of the internal filter, for guarantying good transient responses; however local parameter variations imply structural instability, thus provoking a Hopf bifurcation and a route to chaos for the phase error. Here, one usual architecture for a third-order PLL is studied and a range of permitted parameters is derived, providing a rule of thumb for designers. Out of this range, a Hopf bifurcation appears and, by increasing parameters, the periodic solution originated by the Hopf bifurcation degenerates into a chaotic attractor, therefore, preventing synchronization.
A water bag theory of autoresonant Bernstein-Greene-Kruskal modes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khain, P.; Friedland, L.
2007-08-15
The adiabatic water bag theory describing formation and passage through phase-space of driven, continuously phase-locked (autoresonant) coherent structures in plasmas [L. Friedland et al., Phys. Rev. Lett. 96, 225001 (2006)] and of the associated Bernstein-Greene-Kruskal (BGK) modes is developed. The phase-locking is achieved by using a chirped frequency ponderomotive drive, passing through kinetic Cerenkov-type resonances. The theory uses the adiabatic invariants (conserved actions of limiting trajectories) in the problem and, for a flat-top initial distribution of the electrons, reduces the calculation of the self-field of the driven BGK mode to solution of a few algebraic equations. The adiabatic multiwater bagmore » extension of the theory for applications to autoresonant BGK structures with more general initial distributions is suggested. The results of the theories are in very good agreement with numerical simulations.« less
Borri, Simone; Siciliani de Cumis, Mario; Insero, Giacomo; Bartalini, Saverio; Cancio Pastor, Pablo; Mazzotti, Davide; Galli, Iacopo; Giusfredi, Giovanni; Santambrogio, Gabriele; Savchenkov, Anatoliy; Eliyahu, Danny; Ilchenko, Vladimir; Akikusa, Naota; Matsko, Andrey; Maleki, Lute; De Natale, Paolo
2016-01-01
The need for highly performing and stable methods for mid-IR molecular sensing and metrology pushes towards the development of more and more compact and robust systems. Among the innovative solutions aimed at answering the need for stable mid-IR references are crystalline microresonators, which have recently shown excellent capabilities for frequency stabilization and linewidth narrowing of quantum cascade lasers with compact setups. In this work, we report on the first system for mid-IR high-resolution spectroscopy based on a quantum cascade laser locked to a CaF2 microresonator. Electronic locking narrows the laser linewidth by one order of magnitude and guarantees good stability over long timescales, allowing, at the same time, an easy way for finely tuning the laser frequency over the molecular absorption line. Improvements in terms of resolution and frequency stability of the source are demonstrated by direct sub-Doppler recording of a molecular line. PMID:26901199
Nuclear reactor fuel assembly duct-tube-to-handling-socket attachment system
Christiansen, David W.; Smith, Bob G.
1982-01-01
A reusable system for removably attaching the upper end 10of a nuclear reactor duct tube to the lower end 30 of a nuclear reactor fuel assembly handling socket. A transition ring 20, fixed to the duct tube's upper end 10, has an interior-threaded section 22 with a first locking hole segment 24. An adaptor ring 40, fixed to the handling socket's lower end 30 has an outside-threaded section 42 with a second locking hole segment 44. The inside 22 and outside 42 threaded sections match and can be joined so that the first 24 and second 44 locking hole segments can be aligned to form a locking hole. A locking ring 50, with a locking pin 52, slides over the adaptor ring 40 so that the locking pin 52 fits in the locking hole. A swage lock 60 or a cantilever finger lock 70 is formed from the locking cup collar 26 to fit in a matching groove 54 or 56 in the locking ring 50 to prevent the locking ring's locking pin 52 from backing out of the locking hole.
Urethral catheter insertion forces: a comparison of experience and training.
Canales, Benjamin K; Weiland, Derek; Reardon, Scott; Monga, Manoj
2009-01-01
This study was undertaken to evaluate the insertion forces utilized during simulated placement of a urethral catheter by healthcare individuals with a variety of catheter experience. A 21F urethral catheter was mounted to a metal spring. Participants were asked to press the tubing spring against a force gauge and stop when they met a level of resistance that would typically make them terminate a catheter placement. Simulated catheter insertion was repeated fives times, and peak compression forces were recorded. Healthcare professionals were divided into six groups according to their title: urology staff, non-urology staff, urology resident/ fellow, non-urology resident/ fellow, medical student, and registered nurse. A total of fifty-seven healthcare professionals participated in the study. Urology staff (n = 6) had the lowest average insertion force for any group at 6.8 +/- 2.0 Newtons (N). Medical students (n = 10) had the least amount of experience (1 +/- 0 years) and the highest average insertion force range of 10.1 +/- 3.7 N. Health care workers with greater than 25 years experience used significantly less force during catheter insertions (4.9 +/- 1.8 N) compared to all groups (p < 0.01). We propose the maximum force that should be utilized during urethral catheter insertion is 5 Newtons. This force deserves validation in a larger population and should be considered when designing urethral catheters or creating catheter simulators. Understanding urethral catheter insertion forces may also aid in establishing competency parameters for health care professionals in training.
Embryo Transfer Catheters: Softer is Easier.
Ruhlmann, Claudio; Gnocchi, Diego C; Cattaneo, Antonio R; Molina, Lucas G; Rivadeneira, Luciano Ruiz; Tessari, Lautaro; Martínez, Alejandro G
2015-11-01
This study aimed to compare the use of semi-rigid and flexible catheters in terms of pregnancy rate and level of difficulty of the embryo transfer (ET) procedure. Seven hundred and thirty-nine consecutive follicular aspirations for IVF or ICSI performed in our private fertility clinic within a 30-month period were randomly divided into two groups. Patients were allocated to either of the groups at the time of follicular retrieval with the aid of a random number generator according to the catheter used in ET: Group 1 (n = 370) - Frydman Classic Catheter 4.5 catheters; and Group 2 (n = 369) - Frydman Ultrasoft 4.5 catheters. Only patients offered ET in the randomized cycle were included (Group 1 = 363 and Group 2 = 340). Patients did not change groups after catheter allocation. Statistical analysis was carried out using an unpaired t-test or a chi square test as appropriate. Differences with P<0.05 were considered. A statistically significant difference in favor of the use of the Ultrasoft catheter was evident for parameters use of a tenaculum (19.8% vs. 5.9%) or a hysterometer (5.0% vs. 1.2%), presence of blood during post-ET inspection of the catheter (9.9% vs. 3.8%), and implantation rate (13.0% vs. 16.4%). Clinical pregnancy and delivery rates were comparable in both groups. Our results suggest that a softer catheter may help with difficult ETs. Softer catheters, as also reported by other authors, resulted in better implantation rates.
THE PRESERVATION OF LIVING RED BLOOD CELLS IN VITRO
Rous, Peyton; Turner, J. R.
1916-01-01
The erythrocytes of some species are much damaged when handled in salt solutions, as in washing with the centrifuge after the ordinary method. The injury is mechanical in character. It may express itself in hemolysis only after the cells have been kept for some days. It is greatest in the case of dog corpuscles, and well marked with sheep and rabbit cells. The fragility of the red cells, as indicated by washing or shaking them in salt solution is different, not only for different species, but for different individuals. It varies independently of the resistance to hypotonic solutions. The protection of fragile erythrocytes during washing is essential if they are to be preserved in vitro for any considerable time. The addition of a little gelatin (⅛ per cent) to the wash fluid suffices for this purpose, and by its use the period of survival in salt solutions of washed rabbit, sheep, and dog cells is greatly prolonged. Plasma, like gelatin, has marked protective properties. Though gelatin acts as a protective for red cells it is not preservative of them in the real sense. Cells do not last longer when it is added to the fluids in which they are kept. Locke's solution, though better probably than Ringer's solution, or a sodium chloride solution, as a medium in which to keep red cells, is ultimately harmful. The addition of innocuous colloids does not improve it. But the sugars, especially dextrose and saccharose, have a remarkable power to prevent its injurious action, and they possess, in addition, preservative qualities. Cells washed in gelatin-Locke's and placed in a mixture of Locke's solution with an isotonic, watery solution of a sugar remain intact for a long time,—nearly 2 months in the case of sheep cells. The kept cells go easily into suspension free of clumps, they pass readily through paper filters, take up and give off oxygen, and when used for the Wassermann reaction behave exactly as do fresh cells of the same individual. The best preservative solutions are approximately isotonic with the blood serum. If the cells are to be much handled gelatin should be present, for the sugars do not protect against mechanical injury. Different preservative mixtures are required for the cells of different species. Dog cells last longest in fluids containing dextrin as well as a sugar. The mixture best for red cells is not necessarily best for leukocytes. A simple and practical method of keeping rabbit and human erythrocytes is in citrated whole blood to which sugar solution is added. In citrated blood, as such, human red cells tend to break down rather rapidly, no matter what the proportion of citrate. Hemolysis is well marked after little more than a week. But in a mixture of 3 parts of human blood, 2 parts of isotonic citrate solution (3.8 per cent sodium citrate in water), and 5 parts of isotonic dextrose solution (5.4 per cent dextrose in water), the cells remain intact for about 4 weeks. Rabbit red cells can be kept for more than 3 weeks in citrated blood; and the addition of sugar lengthens the preservation only a little. The results differ strikingly with the amount of citrate employed. Hemolysis occurs relatively early when the smallest quantity is used that will prevent clotting. The optimum mixture has 3 parts of rabbit blood to 2 of isotonic citrate solution. In the second part of this paper experiments are detailed which prove that cells preserved by the methods here recorded function excellently when reintroduced into the body. PMID:19867981
DOE Office of Scientific and Technical Information (OSTI.GOV)
Damato, Antonio L., E-mail: adamato@lroc.harvard.edu; Viswanathan, Akila N.; Don, Sarah M.
2014-10-15
Purpose: To investigate the use of a system using electromagnetic tracking (EMT), post-processing and an error-detection algorithm for detecting errors and resolving uncertainties in high-dose-rate brachytherapy catheter digitization for treatment planning. Methods: EMT was used to localize 15 catheters inserted into a phantom using a stepwise acquisition technique. Five distinct acquisition experiments were performed. Noise associated with the acquisition was calculated. The dwell location configuration was extracted from the EMT data. A CT scan of the phantom was performed, and five distinct catheter digitization sessions were performed. No a priori registration of the CT scan coordinate system with the EMTmore » coordinate system was performed. CT-based digitization was automatically extracted from the brachytherapy plan DICOM files (CT), and rigid registration was performed between EMT and CT dwell positions. EMT registration error was characterized in terms of the mean and maximum distance between corresponding EMT and CT dwell positions per catheter. An algorithm for error detection and identification was presented. Three types of errors were systematically simulated: swap of two catheter numbers, partial swap of catheter number identification for parts of the catheters (mix), and catheter-tip shift. Error-detection sensitivity (number of simulated scenarios correctly identified as containing an error/number of simulated scenarios containing an error) and specificity (number of scenarios correctly identified as not containing errors/number of correct scenarios) were calculated. Catheter identification sensitivity (number of catheters correctly identified as erroneous across all scenarios/number of erroneous catheters across all scenarios) and specificity (number of catheters correctly identified as correct across all scenarios/number of correct catheters across all scenarios) were calculated. The mean detected and identified shift was calculated. Results: The maximum noise ±1 standard deviation associated with the EMT acquisitions was 1.0 ± 0.1 mm, and the mean noise was 0.6 ± 0.1 mm. Registration of all the EMT and CT dwell positions was associated with a mean catheter error of 0.6 ± 0.2 mm, a maximum catheter error of 0.9 ± 0.4 mm, a mean dwell error of 1.0 ± 0.3 mm, and a maximum dwell error of 1.3 ± 0.7 mm. Error detection and catheter identification sensitivity and specificity of 100% were observed for swap, mix and shift (≥2.6 mm for error detection; ≥2.7 mm for catheter identification) errors. A mean detected shift of 1.8 ± 0.4 mm and a mean identified shift of 1.9 ± 0.4 mm were observed. Conclusions: Registration of the EMT dwell positions to the CT dwell positions was possible with a residual mean error per catheter of 0.6 ± 0.2 mm and a maximum error for any dwell of 1.3 ± 0.7 mm. These low residual registration errors show that quality assurance of the general characteristics of the catheters and of possible errors affecting one specific dwell position is possible. The sensitivity and specificity of the catheter digitization verification algorithm was 100% for swap and mix errors and for shifts ≥2.6 mm. On average, shifts ≥1.8 mm were detected, and shifts ≥1.9 mm were detected and identified.« less
Hu, Mei-Hua; Chan, Wei-Hung; Chen, Yao-Chang; Cherng, Chen-Hwan; Lin, Chih-Kung; Tsai, Chien-Sung; Chou, Yu-Ching; Huang, Go-Shine
2016-01-01
The effects of intravenous (IV) catheter gauge and pressurization of IV fluid (IVF) bags on fluid flow rate have been studied. However, the pressure needed to achieve a flow rate equivalent to that of a 16 gauge (G) catheter through smaller G catheters and the potential for endothelial damage from the increased kinetic energy produced by higher pressurization are unclear. Constant pressure on an IVF bag was maintained by an automatic adjustable pneumatic pressure regulator of our own design. Fluids running through 16 G, 18 G, 20 G, and 22 G catheters were assessed while using IV bag pressurization to achieve the flow rate equivalent to that of a 16 G catheter. We assessed flow rates, kinetic energy, and flow injury to rabbit inferior vena cava endothelium. By applying sufficient external constant pressure to an IVF bag, all fluids could be run through smaller (G) catheters at the flow rate in a 16 G catheter. However, the kinetic energy increased significantly as the catheter G increased. Damage to the venous endothelium was negligible or minimal/patchy cell loss. We designed a new rapid infusion system, which provides a constant pressure that compresses the fluid volume until it is free from visible residual fluid. When large-bore venous access cannot be obtained, multiple smaller catheters, external pressure, or both should be considered. However, caution should be exercised when fluid pressurized to reach a flow rate equivalent to that in a 16 G catheter is run through a smaller G catheter because of the profound increase in kinetic energy that can lead to venous endothelium injury.
Briggs, Victoria; Pitcher, David; Braddon, Fiona; Fogarty, Damian; Wilkie, Martin
2013-01-01
The central paradigm of effective peritoneal dialysis (PD) is an appropriate standard of PD catheter function. The aim of the project was to develop an effective national PD access audit which would identify an 'appropriate standard' of PD catheter function. The UK Renal Registry collected centre specific information on various PD access outcome measures including catheter functionality and post-insertion complications. The first PD access audit covering England, Northern Ireland and Wales was conducted during April to June 2012 looking at incident dialysis patients in 2011. Forty three data collection spreadsheets were returned from a total of 65 centres describing 917 PD catheter placements. The median age of PD patients was 61 years and 61.5% were male. The proportion of patients initiated on PD in comparison to HD was lower in socially deprived areas. There was a relationship between the timing of nephrology referral and the likelihood of surgical assessment regarding PD catheter placement. Patients with diabetes did not have higher rates of PD catheter failure or of early peritonitis. A comparative PD catheter audit has the potential to provide valuable information on an important patient related outcome measure and lead to an improvement in patient experience. There was wide variation between centres of PD catheter use for late presenting patients. Overall patients were more likely to get a PD catheter if they had been known to the service for more than 1 year. The percutaneous insertion technique was associated with a higher early (less than 2 week) peritonitis rate and more catheter flow problems. Copyright © 2013 S. Karger AG, Basel.
Holly, Rick; Morton, Gerard C; Sankreacha, Raxa; Law, Niki; Cisecki, Thomas; Loblaw, D Andrew; Chung, Hans T
2011-01-01
To determine the magnitude of catheter displacement between time of planning and time of treatment delivery for patients undergoing high dose-rate (HDR) brachytherapy, the dosimetric impact of catheter displacement, and the ability to improve dosimetry by catheter readjustment. Twenty consecutive patients receiving single fraction HDR brachytherapy underwent kilovoltage cone-beam CT in the treatment room before treatment. If catheter displacement was apparent, catheters were adjusted and imaging repeated. Both sets of kilovoltage cone-beam CT image sets were coregistered off-line with the CT data set used for planning with rigid fusion of anatomy based on implanted fiducials. Catheter displacement was measured on both sets of images and dosimetry calculated. Mean internal displacement of catheters was 11mm. This would have resulted in a decrease in mean volume receiving 100% of prescription dose (V(100)) from the planned 97.6% to 77.3% (p<0.001), a decrease of the mean dose to 90% of the prostate (D(90)) from 110.5% to 72.9% (p<0.001), and increase in dose to 10% of urethra (urethra D(10)) from 118% to 125% (p=0.0094). Each 1cm of catheter displacement resulted in a 20% decrease in V(100) and 36% decrease in D(90). Catheter readjustment resulted in a final treated mean V(100) of 90.2% and D(90) of 97.4%, both less than planned. Mean urethra D(10) remained higher at126% (p=0.0324). Significantly, internal displacement of HDR catheters commonly occurs between time of CT planning and treatment delivery, even when only a single fraction is used. The adverse effects on dosimetry can be partly corrected by readjustment of catheter position. Copyright © 2011 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Lippi, Giuseppe; Cervellin, Gianfranco; Mattiuzzi, Camilla
2013-01-01
Background: A number of preanalytical activities strongly influence sample quality, especially those related to sample collection. Since blood drawing through intravenous catheters is reported as a potential source of erythrocyte injury, we performed a critical review and meta-analysis about the risk of catheter-related hemolysis. Materials and methods: We performed a systematic search on PubMed, Web of Science and Scopus to estimate the risk of spurious hemolysis in blood samples collected from intravenous catheters. A meta-analysis with calculation of Odds ratio (OR) and Relative risk (RR) along with 95% Confidence interval (95% CI) was carried out using random effect mode. Results: Fifteen articles including 17 studies were finally selected. The total number of patients was 14,796 in 13 studies assessing catheter and evacuated tubes versus straight needle and evacuated tubes, and 1251 in 4 studies assessing catheter and evacuated tubes versus catheter and manual aspiration. A significant risk of hemolysis was found in studies assessing catheter and evacuated tubes versus straight needle and evacuated tubes (random effect OR 3.4; 95% CI = 2.9–3.9 and random effect RR 1.07; 95% CI = 1.06–1.08), as well as in studies assessing catheter and evacuated tubes versus catheter and manual aspiration of blood (OR 3.7; 95% CI = 2.7–5.1 and RR 1.32; 95% CI = 1.24–1.40). Conclusions: Sample collection through intravenous catheters is associated with significant higher risk of spurious hemolysis as compared with standard blood drawn by straight needle, and this risk is further amplified when intravenous catheter are associated with primary evacuated blood tubes as compared with manual aspiration. PMID:23894864
A 6-Fr Guiding Catheter (Slim Guide®) for Use with Multiple Microdevices
Kai, Y.; Ohmori, Y.; Watanabe, M.; Kaku, Y.; Morioka, M.; Hirano, T.; Yano, S.; Kawano, T.; Hamada, J-I.; Kuratsu, J-I.
2013-01-01
Summary A modified technique is required in patients with wide-necked aneurysms whose treatment by the single microcatheter technique is difficult. We developed a 6-Fr guiding catheter (Slim Guide®) that features a large lumen (0.072 inch) for performing the modified technique. To evaluate the usefulness of Slim Guide® we carried out experiments using three types of 6-Fr guiding catheter. In experiment 1, the shaft hardness and kink resistance were compared among three different guiding catheters (Slim Guide®, Launcher®, Envoy®). In experiment 2, we inserted a microballoon catheter and a microcatheter into the three different guiding catheters and recorded the maximal infusion pressure. In experiment 3, we inserted 13 different types of microdevices into the three different guiding catheters and evaluated the resistance of the microdevices. Although the shaft of the Slim Guide® was softer than that of the other two guiding catheters, its kink resistance was comparable. The maximal infusion pressure was significantly lower than with Launcher® or Envoy® catheters. Furthermore, with Slim Guide®, in 136 of 143 microdevice combinations examined (95.1%) there was no resistance; this was true for 125 (87.4%) and 116 (81.1%) combinations using the Launcher® - and the Envoy® guiding catheters, respectively. There was a significant difference between Slim Guide® and the other two guiding catheters with respect to their accommodation of double microsystems (p<0.05). Although the inner diameter of Slim Guide® is slightly larger than of the other two guiding catheters, it significantly increased the combination of microdevices that could be used for the coil embolization of difficult aneurysms. PMID:23472717
A 6-fr guiding catheter (slim guide(®)) for use with multiple microdevices. An experimental study.
Kai, Y; Ohmori, Y; Watanabe, M; Kaku, Y; Morioka, M; Hirano, T; Yano, S; Kawano, T; Hamada, J-I; Kuratsu, J-I
2013-03-01
A modified technique is required in patients with wide-necked aneurysms whose treatment by the single microcatheter technique is difficult. We developed a 6-Fr guiding catheter (Slim Guide(®)) that features a large lumen (0.072 inch) for performing the modified technique. To evaluate the usefulness of Slim Guide(®) we carried out experiments using three types of 6-Fr guiding catheter. In experiment 1, the shaft hardness and kink resistance were compared among three different guiding catheters (Slim Guide(®), Launcher(®), Envoy(®)). In experiment 2, we inserted a microballoon catheter and a microcatheter into the three different guiding catheters and recorded the maximal infusion pressure. In experiment 3, we inserted 13 different types of microdevices into the three different guiding catheters and evaluated the resistance of the microdevices. Although the shaft of the Slim Guide(®) was softer than that of the other two guiding catheters, its kink resistance was comparable. The maximal infusion pressure was significantly lower than with Launcher(®) or Envoy(®) catheters. Furthermore, with Slim Guide(®), in 136 of 143 microdevice combinations examined (95.1%) there was no resistance; this was true for 125 (87.4%) and 116 (81.1%) combinations using the Launcher(®) - and the Envoy(®) guiding catheters, respectively. There was a significant difference between Slim Guide(®) and the other two guiding catheters with respect to their accommodation of double microsystems (p<0.05). Although the inner diameter of Slim Guide(®) is slightly larger than of the other two guiding catheters, it significantly increased the combination of microdevices that could be used for the coil embolization of difficult aneurysms.
Ablordeppey, Enyo A; Drewry, Anne M; Beyer, Alexander B; Theodoro, Daniel L; Fowler, Susan A; Fuller, Brian M; Carpenter, Christopher R
2017-04-01
We performed a systematic review and meta-analysis to examine the accuracy of bedside ultrasound for confirmation of central venous catheter position and exclusion of pneumothorax compared with chest radiography. PubMed, Embase, Cochrane Central Register of Controlled Trials, reference lists, conference proceedings and ClinicalTrials.gov. Articles and abstracts describing the diagnostic accuracy of bedside ultrasound compared with chest radiography for confirmation of central venous catheters in sufficient detail to reconstruct 2 × 2 contingency tables were reviewed. Primary outcomes included the accuracy of confirming catheter positioning and detecting a pneumothorax. Secondary outcomes included feasibility, interrater reliability, and efficiency to complete bedside ultrasound confirmation of central venous catheter position. Investigators abstracted study details including research design and sonographic imaging technique to detect catheter malposition and procedure-related pneumothorax. Diagnostic accuracy measures included pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. Fifteen studies with 1,553 central venous catheter placements were identified with a pooled sensitivity and specificity of catheter malposition by ultrasound of 0.82 (0.77-0.86) and 0.98 (0.97-0.99), respectively. The pooled positive and negative likelihood ratios of catheter malposition by ultrasound were 31.12 (14.72-65.78) and 0.25 (0.13-0.47). The sensitivity and specificity of ultrasound for pneumothorax detection was nearly 100% in the participating studies. Bedside ultrasound reduced mean central venous catheter confirmation time by 58.3 minutes. Risk of bias and clinical heterogeneity in the studies were high. Bedside ultrasound is faster than radiography at identifying pneumothorax after central venous catheter insertion. When a central venous catheter malposition exists, bedside ultrasound will identify four out of every five earlier than chest radiography.
Tavallali, Hossein; Deilamy-Rad, Gohar; Parhami, Abolfath; Hasanli, Nahid
2014-02-15
Rhodamine B (RhB) an available dye has been developed as novel and efficient colorimetric and fluorometric chemosensor for cyanide ions in an absolutely aqueous media. The UV-vis absorption and fluorescent emission titrations experiments have been employed to study the sensing process. RhB could act as an efficient "ON-OFF" fluorescent response for phosphotungstic acid (H3PW12O40 or PTA) based on an ion associate process. Also (RhB(+))3 · PTA(3-) could operate as an "OFF-ON" fluorescent sensor for cyanide anions based on a ligand substitution process. It has been identified as highly sensitive probe for CN(-) which responds at 0.3 and 0.04 μmol L(-1) concentration levels by absorption and fluorescent method respectively. Depending upon the sequence of addition of PTA and CN(-) ions into the solution, RhB could be as a molecular security keypad lock with PTA and CN(-) inputs. The ionic inputs to new fluorophore have been mimicked as a superimposed electronic molecular keypad lock. The results were compared successfully (>96%) with the data of a spectrophotometry approved method (EPA 9014-1) for cyanide ions. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Witt, Thomas J.; Fletcher, N. E.
2010-10-01
We investigate some statistical properties of ac voltages from a white noise source measured with a digital lock-in amplifier equipped with finite impulse response output filters which introduce correlations between successive voltage values. The main goal of this work is to propose simple solutions to account for correlations when calculating the standard deviation of the mean (SDM) for a sequence of measurement data acquired using such an instrument. The problem is treated by time series analysis based on a moving average model of the filtering process. Theoretical expressions are derived for the power spectral density (PSD), the autocorrelation function, the equivalent noise bandwidth and the Allan variance; all are related to the SDM. At most three parameters suffice to specify any of the above quantities: the filter time constant, the time between successive measurements (both set by the lock-in operator) and the PSD of the white noise input, h0. Our white noise source is a resistor so that the PSD is easily calculated; there are no free parameters. Theoretical expressions are checked against their respective sample estimates and, with the exception of two of the bandwidth estimates, agreement to within 11% or better is found.
Cortese, Antonio; Savastano, Mauro; Cantone, Antonio; Claudio, Pier Paolo
2013-07-01
A new palatal distractor device for bodily movement of the maxillary bones after complete segmented Le Fort I osteotomy for 1-stage transversal distraction and tridimensional repositioning on 1 patient is presented. The new distractor has an intrinsic tridimensional rigidity also in the fixation system by self-locking miniplates and screws for better control of the 2 maxillary fragments during distraction. Le Fort I distraction and repositioning procedure in association with a bilateral sagittal split osteotomy were performed on 1 patient with complete solution of the cross-bite and class III malocclusion. Results of dental and cephalometric analysis performed before surgery (T1), after surgery and distraction time (T2), and 18 months after surgery and orthodontic appliance removal (T3) are reported. No complications were encountered using the new distractor device. Advantages of this device and technique are presented including improved rigidity of both distraction (jackscrew) and fixation (4 self-locking miniplates and screws) systems resulting in complete control of the position of the 2 maxillary fragments during distraction and surgery. In addition, this new device allows resuming palatal distraction in the event of cross-bite relapse without causing dental-related problems or the risks of screw slackening.
Spatiotemporal dynamics of a digital phase-locked loop based coupled map lattice system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Banerjee, Tanmoy, E-mail: tbanerjee@phys.buruniv.ac.in; Paul, Bishwajit; Sarkar, B. C.
2014-03-15
We explore the spatiotemporal dynamics of a coupled map lattice (CML) system, which is realized with a one dimensional array of locally coupled digital phase-locked loops (DPLLs). DPLL is a nonlinear feedback-controlled system widely used as an important building block of electronic communication systems. We derive the phase-error equation of the spatially extended system of coupled DPLLs, which resembles a form of the equation of a CML system. We carry out stability analysis for the synchronized homogeneous solutions using the circulant matrix formalism. It is shown through extensive numerical simulations that with the variation of nonlinearity parameter and coupling strengthmore » the system shows transitions among several generic features of spatiotemporal dynamics, viz., synchronized fixed point solution, frozen random pattern, pattern selection, spatiotemporal intermittency, and fully developed spatiotemporal chaos. We quantify the spatiotemporal dynamics using quantitative measures like average quadratic deviation and spatial correlation function. We emphasize that instead of using an idealized model of CML, which is usually employed to observe the spatiotemporal behaviors, we consider a real world physical system and establish the existence of spatiotemporal chaos and other patterns in this system. We also discuss the importance of the present study in engineering application like removal of clock-skew in parallel processors.« less
Spatiotemporal dynamics of a digital phase-locked loop based coupled map lattice system.
Banerjee, Tanmoy; Paul, Bishwajit; Sarkar, B C
2014-03-01
We explore the spatiotemporal dynamics of a coupled map lattice (CML) system, which is realized with a one dimensional array of locally coupled digital phase-locked loops (DPLLs). DPLL is a nonlinear feedback-controlled system widely used as an important building block of electronic communication systems. We derive the phase-error equation of the spatially extended system of coupled DPLLs, which resembles a form of the equation of a CML system. We carry out stability analysis for the synchronized homogeneous solutions using the circulant matrix formalism. It is shown through extensive numerical simulations that with the variation of nonlinearity parameter and coupling strength the system shows transitions among several generic features of spatiotemporal dynamics, viz., synchronized fixed point solution, frozen random pattern, pattern selection, spatiotemporal intermittency, and fully developed spatiotemporal chaos. We quantify the spatiotemporal dynamics using quantitative measures like average quadratic deviation and spatial correlation function. We emphasize that instead of using an idealized model of CML, which is usually employed to observe the spatiotemporal behaviors, we consider a real world physical system and establish the existence of spatiotemporal chaos and other patterns in this system. We also discuss the importance of the present study in engineering application like removal of clock-skew in parallel processors.
Spatiotemporal dynamics of a digital phase-locked loop based coupled map lattice system
NASA Astrophysics Data System (ADS)
Banerjee, Tanmoy; Paul, Bishwajit; Sarkar, B. C.
2014-03-01
We explore the spatiotemporal dynamics of a coupled map lattice (CML) system, which is realized with a one dimensional array of locally coupled digital phase-locked loops (DPLLs). DPLL is a nonlinear feedback-controlled system widely used as an important building block of electronic communication systems. We derive the phase-error equation of the spatially extended system of coupled DPLLs, which resembles a form of the equation of a CML system. We carry out stability analysis for the synchronized homogeneous solutions using the circulant matrix formalism. It is shown through extensive numerical simulations that with the variation of nonlinearity parameter and coupling strength the system shows transitions among several generic features of spatiotemporal dynamics, viz., synchronized fixed point solution, frozen random pattern, pattern selection, spatiotemporal intermittency, and fully developed spatiotemporal chaos. We quantify the spatiotemporal dynamics using quantitative measures like average quadratic deviation and spatial correlation function. We emphasize that instead of using an idealized model of CML, which is usually employed to observe the spatiotemporal behaviors, we consider a real world physical system and establish the existence of spatiotemporal chaos and other patterns in this system. We also discuss the importance of the present study in engineering application like removal of clock-skew in parallel processors.
49 CFR 236.337 - Locking faces of mechanical locking; fit.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Locking faces of mechanical locking; fit. 236.337 Section 236.337 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... Rules and Instructions § 236.337 Locking faces of mechanical locking; fit. Locking faces shall fit...
Solid-state vs water-perfused catheters to measure colonic high-amplitude propagating contractions.
Liem, O; Burgers, R E; Connor, F L; Benninga, M A; Reddy, S N; Mousa, H M; Di Lorenzo, C
2012-04-01
Solid-state (SS) manometry catheters with portable data loggers offer many potential advantages over traditional water-perfused (WP) systems, such as prolonged recordings in a more physiologic ambulatory setting and the lack of risk for water overload. The use of SS catheters has not been evaluated in comparison with perfused catheters in children. This study aims to compare data provided by SS and WP catheters in children undergoing colonic manometry studies. A SS catheter and a WP catheter were taped together such that their corresponding sensors were at the same location. Simultaneous recordings were obtained using the SS and WP catheters (both 8 channels, 10 cm apart) in 15 children with severe defecation disorders referred for colonic manometry. Signals were recorded for a minimum of 1 h during fasting, 1 h after ingestion of a meal, and 1 h after the administration of bisacodyl. Solid-state signals from the data logger were analyzed against the perfused signals. All high-amplitude propagated contractions (HAPCs), the most recognizable and interpreted colonic motor event, were evaluated for spatial and temporal features including their durations, amplitudes, and propagation velocities. A total of 107 HAPCs were detected with SS and 91 with WP catheters. All WP-HAPC were also observed with SS. Linear regression analysis showed that SS catheters tended to give higher readings in the presence of amplitudes <102 mmHg and lower reading with amplitudes >102 mmHg. An opposite trend was found for the duration of contractions. No significant difference was found for HAPC velocity. SS catheters are more sensitive in recording HAPCs in children with defecation disorders compared with the more traditional WP assembly. There is a difference in measurements of amplitude between the two systems. Solid-state catheters offer potential advantages over WP catheters in children, being portable, safer to use, and may provide data over a more prolonged period. © 2012 Blackwell Publishing Ltd.
Risk factor analysis for long-term tunneled dialysis catheter-related bacteremias.
Jean, G; Charra, B; Chazot, C; Vanel, T; Terrat, J C; Hurot, J M; Laurent, G
2002-07-01
Infection, mainly related to vascular access, is one of the main causes of morbidity and a preventable cause of death in hemodialysis patients. From January 1994 to April 1998 we conducted a prospective study to assess the incidence and risk factors of catheter-related bacteremia. One hundred and twenty-nine tunneled dual-lumen hemodialysis catheters were inserted percutaneously into the internal jugular vein in 89 patients. Bacteremia (n = 56) occurred at least once with 37 (29%) of the catheters (an incidence of 1.1/1,000 catheter-days); local infection (n = 45, 1/1,000 catheter-days) was associated with bacteremia in 18 cases. Death in 1 case was directly related to Staphylococcus aureus (SA) septic shock, and septicemia contributed to deaths in 2 additional cases. Catheters were removed in 48% of the bacteremic episodes. Treatment comprised intravenous double antimicrobial therapy for 15-20 days. Bacteriological data of bacteremia showed 55% involvement of SA. Nasal carriage of SA was observed in 35% of the patients with catheters. Bacteremic catheters were more frequently observed in patients with diabetes mellitus (p = 0.03), peripheral atherosclerosis (p = 0.001), a previous history of bacteremia (p = 0.05), nasal carriage of SA (p = 0.0001), longer catheter survival time (p = 0.001), higher total intravenous iron dose (p = 0.001), more frequent urokinase catheter infusion (p < 0.01), and local infection (p < 0.001) compared with non-bacteremic catheters. Monovariate survival analysis showed that significant initial risk factors for bacteremia were nasal carriage of SA (p = 0.00001), previous bacteremia (p = 0.0001), peripheral atherosclerosis (p = 0.005), and diabetes (p = 0.04). This study confirms the relatively high incidence of bacteremia with tunneled double-lumen silicone catheters and its potential complications. Possible preventive actions are discussed according to the risk factors. Copyright 2002 S. Karger AG, Basel
Cicolini, Giancarlo; Manzoli, Lamberto; Simonetti, Valentina; Flacco, Maria Elena; Comparcini, Dania; Capasso, Lorenzo; Di Baldassarre, Angela; Eltaji Elfarouki, Ghaleb
2014-11-01
This multi-centre prospective field study evaluated whether peripheral venous catheter site of insertion influences the risk of catheter-related phlebitis. Potential predictors of phlebitis were also investigated. Millions of patients worldwide use peripheral venous catheters, which frequently cause local complications including phlebitis, infection and obstruction. Although phlebitis predictors have been broadly investigated, uncertainties remain on the potential effect of cannulation anatomical site, duration and the appropriate time for catheter removal. A prospective cohort design was carried out from January-June 2012. The clinical course of each patient who received a new peripheral venous catheter for any cause in five Italian hospitals was followed by trained nurses until catheter removal. The presence of phlebitis was assessed every 24 hours using the Visual Infusion Phlebitis score. Analyses were based upon multilevel mixed-effects regression. The final sample consisted of 1498 patients. The average time for catheters in situ was 65·6 hours and 23·6% of the catheters were in place beyond 96 hours. Overall phlebitis incidence was 15·4%, 94·4% of which were grade 1. The likelihood of phlebitis independently increased with increasing catheter duration, being highest after 96 hours. Compared with patients with catheter placed in the dorsum of the hand (22·8% of the sample), those with the catheter located in the antecubital fossa (34·1%) or forearm were less likely to have a phlebitis of any grade. Antecubital fossa and forearm veins may be preferential sites for peripheral venous cannulation. Our results support Centers for Disease Control and Prevention recommendations to replace catheters in adults no later than 96 hours. A relevant proportion of healthcare personnel did not adhere to such guidelines - more attention to this issue is required. © 2014 John Wiley & Sons Ltd.
Malinova, Vesna; Stockhammer, Florian; Atangana, Etienne Ndzie; Mielke, Dorothee; Rohde, Veit
2014-06-01
The optimal management of spontaneous intracerebral hemorrhage (ICH), especially if deep-seated, remains a matter of discussion. Lysis of the blood clot applying recombinant tissue-type plasminogen activator (rtPA) by an intrahematomal catheter is a minimally invasive treatment option, currently being under investigation in a randomized trial. The center position of the catheter in the hematoma is believed to be crucial for an optimal clot lysis. To achieve this objective, frame-based stereotaxy and frameless stereotaxy with guidance of an articulated arm were used. Recently, a preregistered stylet for direct navigation, alleviating the need of guidance, became available. In this study, we evaluated the relative error (RE) describing the deviation of the catheter from the ideal center position in the clot and compared the accuracy of catheter placement using frameless stereotaxy or the novel preregistered stylet. The intrahematomal catheter position was evaluated in three dimensions in 89 patients with spontaneous supratentorial ICH. Frameless stereotaxy with guidance of an articulated arm was performed in 50 patients. The preregistered stylet was used in 39 patients. The catheter position was evaluated using a RE calculating the distance perpendicular to the center of the catheter in relation to the hematoma's diameter. The mean hematoma volume was 51.4 ml. Forty-four out of 89 hematomas were deep-seated. Intraventricular blood was found in 59 patients. The RE of the catheter position was lower in the stylet group in comparison to the frameless stereotaxy group (mean 0.57 vs. 0.90; p = 0.0018). There was no difference between deep-seated and lobar hematomas with regard to the accuracy of catheter placement (p = 0.62). The RE is a robust measure for describing intrahematomal catheter position. The preregistered stylet facilitates a satisfactory catheter placement and is a viable alternative to frameless stereotaxy and guidance with the articulated arm.