Alonso-Quintela, Paula; Oulego-Erroz, Ignacio; Rodriguez-Blanco, Silvia; Muñiz-Fontan, Manoel; Lapeña-López-de Armentia, Santiago; Rodriguez-Nuñez, Antonio
2015-11-01
To compare the use of bedside ultrasound and chest radiography to verify central venous catheter tip positioning. Prospective observational study. PICU of a university hospital. Patients aged 0-14 who required a central venous catheter. None. Central venous catheter tip location was confirmed by ultrasound and chest radiography. Central venous catheters were classified as intra-atrial or extra-atrial according to their positions in relation to the cavoatrial junction. Central venous catheters located outside the vena cava were considered malpositioned. The distance between the catheter tip and the cavoatrial junction was measured. The time elapsed from image capture to interpretation was recorded. Fifty-one central venous catheters in 40 patients were analyzed. Chest radiography and ultrasound results agreed 94% of the time (κ coefficient, 0.638; p < 0.001) in determining intra-atrial and extra-atrial locations and 92% of the time in determining the diagnosis of central venous catheter malposition (κ coefficient, 0.670; p < 0.001). Chest radiography indicated a greater distance between the central venous catheter tip and the cavoatrial junction than measured by ultrasound, with a mean difference of 0.38 cm (95% CI, +0.27, +0.48 cm). Three central venous catheters were classified as extra-atrial by chest radiography but as intra-atrial by ultrasound. To locate the central venous catheter tip, ultrasound required less time than chest radiography (22.96 min [20.43 min] vs 2.23 min [1.06 min]; p < 0.001). Bedside ultrasound showed a good agreement with chest radiography in detecting central venous catheter tip location and revealing incorrect positions. Ultrasound could be a preferable method for routine verification of central venous catheter tip and can contribute to increased patient safety.
Shape memory alloy/shape memory polymer tools
Seward, Kirk P.; Krulevitch, Peter A.
2005-03-29
Micro-electromechanical tools for minimally invasive techniques including microsurgery. These tools utilize composite shape memory alloy (SMA), shape memory polymer (SMP) and combinations of SMA and SMP to produce catheter distal tips, actuators, etc., which are bistable. Applications for these structures include: 1) a method for reversible fine positioning of a catheter tip, 2) a method for reversible fine positioning of tools or therapeutic catheters by a guide catheter, 3) a method for bending articulation through the body's vasculature, 4) methods for controlled stent delivery, deployment, and repositioning, and 5) catheters with variable modulus, with vibration mode, with inchworm capability, and with articulated tips. These actuators and catheter tips are bistable and are opportune for in vivo usage because the materials are biocompatible and convenient for intravascular use as well as other minimal by invasive techniques.
Gibault, Pierre; Desruennes, Eric; Bourgain, Jean-Louis
2015-01-01
Electrocardiographic (ECG) guidance has been shown to be as effective than fluoroscopy to position the tip of central venous devices close to the superior vena cava (SVC)-right atrium (RA) junction. When SVC access is contraindicated, a femoral access may be used. The aim of this prospective study is to evaluate the effectiveness of ECG guidance to position the tip of femoral ports at inferior vena cava (IVC)-RA junction. Inclusion criterion was the need for femoral port implantation. After insertion of the dilator in the femoral vein, the catheter with the guide wire inside was introduced and the ECG signal collected at the tip of the guide (Celsite™ ECG, B. Braun, Germany) or via saline injected in the catheter (Nautilus™, Perouse, France). Fluoroscopy was performed at each change of the P-wave from IVC to RA. A final X-ray was performed after withdrawing the catheter 2 cm below the first P-wave change. A total of 18 patients were included between December 2011 and June 2013. The P-wave was most often negative in IVC, biphasic when the catheter entered RA and giant and positive at the top of RA. When the catheter was withdraw 2 cm below the first biphasic P-wave the tip was just below the IVC-RA junction in 17 patients. In one patient P-wave changes were not significant and the final position was adjusted under fluoroscopy. ECG guidance is effective to assess catheter tip position during femoral port placement and avoids the need for radiological methods.
Ahn, J H; Kim, I S; Yang, J H; Lee, I G; Seo, D H; Kim, S P
2017-02-01
The lower superior vena cava (SVC), near its junction with the right atrium (RA), is considered the ideal location for the central venous catheter tip to ensure proper function and prevent injuries. We determined catheter insertion depth with a new formula using the sternoclavicular joint and the carina as radiological landmarks, with a 1.5 cm safety margin. The accuracy of tip positioning with the radiological landmark-based technique (R) and Peres' formula (P) was compared using transoesophageal echocardiography. Real-time ultrasound-guided central venous catheter insertion was done through the right internal jugular or subclavian vein. Patients were randomly assigned to either the P group (n=93) or the R group (n=95). Optimal catheter tip position was considered to be within 2 cm above and 1 cm below the RA-SVC junction. Catheter tip position, abutment, angle to the vascular wall, and flow stream were evaluated on a bicaval view. The distance from the skin insertion point to the RA-SVC junction and determined depth of catheter insertion were more strongly correlated in the R group [17.4 (1.2) and 16.7 (1.5) cm; r=0.821, P<0.001] than in the P group [17.3 (1.2) and 16.4 (1.1) cm; r=0.517, P<0.001], with z=3.96 (P<0.001). More tips were correctly positioned in the R group than in the P group (74 vs 93%, P=0.001). Abutment, tip angle to the lateral wall >40°, and disrupted flow stream were comparable. Catheter tip position was more accurate with a radiological landmark-based technique than with Peres' formula. Clinical Trial Registry of Korea: https://cris.nih.go.kr/cris/index.jsp KCT0001937. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Francel, P C; Stevens, F A; Tompkins, P; Pollay, M
2001-02-01
The proper functioning of shunt valves in vivo is dependent on many factors, including the valve itself, the anti-siphon device or ASD (if included), patency of inlet and outlet tubing, and location of the valve. One important, but sometimes overlooked, consideration in valve function is the valve location relative to the tip of the ventricular inlet catheter. As with any pressure measurement, the zero or reference position is an important concept. In the case of shunt valves, the position of the proximal inlet catheter tip is fixed and therefore serves as the reference point for all pressure measurements. This study was conducted to document the importance of this relationship for the pressure/flow characteristics of the shunt valve. We bench-tested differential pressure valves (with integral anti-gravity devices; AGDs) from three manufacturers. Valves were connected to an "infinite" reservoir, and the starting head pressure for each was determined from product inserts. The inlet catheter tip was fixed at this position, and the valve body was moved in relation to the inlet catheter tip. Outflow rates were determined gravimetrically for positions varying between 4 cm above and 8 cm below the inlet catheter tip. All differential pressure valves utilized in this study that contained AGDs showed significant increases in outflow rate as the valve body was moved incrementally below the level of the inlet catheter tip. To allow functioning as a zero-hydrostatic pressure differential pressure valve, the AGD and the inlet catheter tip should be aligned at the same horizontal level.
Are central venous catheter tip cultures reliable after 6-day refrigeration?
Bouza, Emilio; Guembe, Maria; Gómez, Haydee; Martín-Rabadán, Pablo; Rivera, Marisa; Alcalá, Luis
2009-07-01
Present guidelines recommend culturing only central venous catheter (CVC) tips from patients with suspected catheter-related bloodstream infection (CR-BSI). However, a high proportion of these suspicions are not confirmed. Moreover, CVC tip culture increases laboratory workload, and reports of colonization may be meaningless or misleading for the clinician. Our working hypothesis was that CVC tips should be refrigerated and cultured only in patients with positive blood cultures. We evaluated the effect of 6-day refrigeration of 215 CVC tips. We selected all the catheters with a significant count according to the Maki's roll-plate technique and randomly assigned them to 2 groups. In group A, the catheters were recultured after 24 h of refrigeration, and in group B, the catheters were recultured after 6 days more of refrigeration, so that the refrigeration time evaluated would be of 6 days. The yield of refrigerated CVC tips that grow significant colony counts of primary culture in group B was compared with the yield of refrigerated catheter tips in group A. The difference showed that 6-day refrigeration reduced the number of significant CVCs by 15.2%. Only 61 CVCs were obtained from patients with CR-BSI, and in most of them, blood cultures were already positive before CVC culture, so only 0.91% of the CR-BSI episodes would have been misdiagnosed as culture negative after refrigeration. Refrigeration of CVC tips sent for culture and culturing only those from patients with positive blood cultures reduce the workload in the microbiology laboratory without misdiagnosing CR-BSI.
Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy.
Wang, Wei; Viswanathan, Akila N; Damato, Antonio L; Chen, Yue; Tse, Zion; Pan, Li; Tokuda, Junichi; Seethamraju, Ravi T; Dumoulin, Charles L; Schmidt, Ehud J; Cormack, Robert A
2015-12-01
In gynecologic cancers, magnetic resonance (MR) imaging is the modality of choice for visualizing tumors and their surroundings because of superior soft-tissue contrast. Real-time MR guidance of catheter placement in interstitial brachytherapy facilitates target coverage, and would be further improved by providing intraprocedural estimates of dosimetric coverage. A major obstacle to intraprocedural dosimetry is the time needed for catheter trajectory reconstruction. Herein the authors evaluate an active MR tracking (MRTR) system which provides rapid catheter tip localization and trajectory reconstruction. The authors assess the reliability and spatial accuracy of the MRTR system in comparison to standard catheter digitization using magnetic resonance imaging (MRI) and CT. The MRTR system includes a stylet with microcoils mounted on its shaft, which can be inserted into brachytherapy catheters and tracked by a dedicated MRTR sequence. Catheter tip localization errors of the MRTR system and their dependence on catheter locations and orientation inside the MR scanner were quantified with a water phantom. The distances between the tracked tip positions of the MRTR stylet and the predefined ground-truth tip positions were calculated for measurements performed at seven locations and with nine orientations. To evaluate catheter trajectory reconstruction, fifteen brachytherapy catheters were placed into a gel phantom with an embedded catheter fixation framework, with parallel or crossed paths. The MRTR stylet was then inserted sequentially into each catheter. During the removal of the MRTR stylet from within each catheter, a MRTR measurement was performed at 40 Hz to acquire the instantaneous stylet tip position, resulting in a series of three-dimensional (3D) positions along the catheter's trajectory. A 3D polynomial curve was fit to the tracked positions for each catheter, and equally spaced dwell points were then generated along the curve. High-resolution 3D MRI of the phantom was performed followed by catheter digitization based on the catheter's imaging artifacts. The catheter trajectory error was characterized in terms of the mean distance between corresponding dwell points in MRTR-generated catheter trajectory and MRI-based catheter digitization. The MRTR-based catheter trajectory reconstruction process was also performed on three gynecologic cancer patients, and then compared with catheter digitization based on MRI and CT. The catheter tip localization error increased as the MRTR stylet moved further off-center and as the stylet's orientation deviated from the main magnetic field direction. Fifteen catheters' trajectories were reconstructed by MRTR. Compared with MRI-based digitization, the mean 3D error of MRTR-generated trajectories was 1.5 ± 0.5 mm with an in-plane error of 0.7 ± 0.2 mm and a tip error of 1.7 ± 0.5 mm. MRTR resolved ambiguity in catheter assignment due to crossed catheter paths, which is a common problem in image-based catheter digitization. In the patient studies, the MRTR-generated catheter trajectory was consistent with digitization based on both MRI and CT. The MRTR system provides accurate catheter tip localization and trajectory reconstruction in the MR environment. Relative to the image-based methods, it improves the speed, safety, and reliability of the catheter trajectory reconstruction in interstitial brachytherapy. MRTR may enable in-procedural dosimetric evaluation of implant target coverage.
Wang, Guorong; Guo, Ling; Jiang, Bin; Huang, Min; Zhang, Jian; Qin, Ying
2015-01-01
Amplitude changes in the P-wave of intracavitary electrocardiography have been used to assess the tip placement of central venous catheters. The research assessed the sensitivity and specificity of this sign in comparison with standard radiographic techniques for tip location, focusing on factors influencing its clinical utility. Both intracavitary electrocardiography guided tip location and X-ray positioning were used to verify catheter tip locations in patients undergoing central venous catheter insertion. Intracavitary electrocardiograms from 1119 patients (of a total 1160 subjects) showed specific amplitude changes in the P-wave. As the results show, compared with X-ray positioning, the sensitivity of electrocardiography-guided tip location was 97.3%, with false negative rate of 2.7%; the specificity was 1, with false positive rate of zero. Univariate analyses indicated that features including age, gender, height, body weight, and heart rate have no statistically significant influence on P-wave amplitude changes (P>0.05). Multivariate logistic regression revealed that catheter insertion routes (OR = 2.280, P = 0.003) and basal P-wave amplitude (OR = 0.553, P = 0.003) have statistically significant impacts on P-wave amplitude changes. As a reliable indicator of tip location, amplitude change in the P-wave has proved of good sensitivity and excellent specificity, and the minor, zero, false positive rate supports the clinical utility of this technique in early recognition of malpositioned tips. A better sensitivity was achieved in placement of centrally inserted central catheters (CICCs) than that of peripherally inserted central catheters (PICCs). In clinical practice, a combination of intracavitary electrocardiography, ultrasonic inspection and the anthropometric measurement method would further improve the accuracy. PMID:25915758
Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy
Wang, Wei; Viswanathan, Akila N.; Damato, Antonio L.; Chen, Yue; Tse, Zion; Pan, Li; Tokuda, Junichi; Seethamraju, Ravi T.; Dumoulin, Charles L.; Schmidt, Ehud J.; Cormack, Robert A.
2015-01-01
Purpose: In gynecologic cancers, magnetic resonance (MR) imaging is the modality of choice for visualizing tumors and their surroundings because of superior soft-tissue contrast. Real-time MR guidance of catheter placement in interstitial brachytherapy facilitates target coverage, and would be further improved by providing intraprocedural estimates of dosimetric coverage. A major obstacle to intraprocedural dosimetry is the time needed for catheter trajectory reconstruction. Herein the authors evaluate an active MR tracking (MRTR) system which provides rapid catheter tip localization and trajectory reconstruction. The authors assess the reliability and spatial accuracy of the MRTR system in comparison to standard catheter digitization using magnetic resonance imaging (MRI) and CT. Methods: The MRTR system includes a stylet with microcoils mounted on its shaft, which can be inserted into brachytherapy catheters and tracked by a dedicated MRTR sequence. Catheter tip localization errors of the MRTR system and their dependence on catheter locations and orientation inside the MR scanner were quantified with a water phantom. The distances between the tracked tip positions of the MRTR stylet and the predefined ground-truth tip positions were calculated for measurements performed at seven locations and with nine orientations. To evaluate catheter trajectory reconstruction, fifteen brachytherapy catheters were placed into a gel phantom with an embedded catheter fixation framework, with parallel or crossed paths. The MRTR stylet was then inserted sequentially into each catheter. During the removal of the MRTR stylet from within each catheter, a MRTR measurement was performed at 40 Hz to acquire the instantaneous stylet tip position, resulting in a series of three-dimensional (3D) positions along the catheter’s trajectory. A 3D polynomial curve was fit to the tracked positions for each catheter, and equally spaced dwell points were then generated along the curve. High-resolution 3D MRI of the phantom was performed followed by catheter digitization based on the catheter’s imaging artifacts. The catheter trajectory error was characterized in terms of the mean distance between corresponding dwell points in MRTR-generated catheter trajectory and MRI-based catheter digitization. The MRTR-based catheter trajectory reconstruction process was also performed on three gynecologic cancer patients, and then compared with catheter digitization based on MRI and CT. Results: The catheter tip localization error increased as the MRTR stylet moved further off-center and as the stylet’s orientation deviated from the main magnetic field direction. Fifteen catheters’ trajectories were reconstructed by MRTR. Compared with MRI-based digitization, the mean 3D error of MRTR-generated trajectories was 1.5 ± 0.5 mm with an in-plane error of 0.7 ± 0.2 mm and a tip error of 1.7 ± 0.5 mm. MRTR resolved ambiguity in catheter assignment due to crossed catheter paths, which is a common problem in image-based catheter digitization. In the patient studies, the MRTR-generated catheter trajectory was consistent with digitization based on both MRI and CT. Conclusions: The MRTR system provides accurate catheter tip localization and trajectory reconstruction in the MR environment. Relative to the image-based methods, it improves the speed, safety, and reliability of the catheter trajectory reconstruction in interstitial brachytherapy. MRTR may enable in-procedural dosimetric evaluation of implant target coverage. PMID:26632065
Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Wei, E-mail: wwang21@partners.org; Viswanathan, Akila N.; Damato, Antonio L.
2015-12-15
Purpose: In gynecologic cancers, magnetic resonance (MR) imaging is the modality of choice for visualizing tumors and their surroundings because of superior soft-tissue contrast. Real-time MR guidance of catheter placement in interstitial brachytherapy facilitates target coverage, and would be further improved by providing intraprocedural estimates of dosimetric coverage. A major obstacle to intraprocedural dosimetry is the time needed for catheter trajectory reconstruction. Herein the authors evaluate an active MR tracking (MRTR) system which provides rapid catheter tip localization and trajectory reconstruction. The authors assess the reliability and spatial accuracy of the MRTR system in comparison to standard catheter digitization usingmore » magnetic resonance imaging (MRI) and CT. Methods: The MRTR system includes a stylet with microcoils mounted on its shaft, which can be inserted into brachytherapy catheters and tracked by a dedicated MRTR sequence. Catheter tip localization errors of the MRTR system and their dependence on catheter locations and orientation inside the MR scanner were quantified with a water phantom. The distances between the tracked tip positions of the MRTR stylet and the predefined ground-truth tip positions were calculated for measurements performed at seven locations and with nine orientations. To evaluate catheter trajectory reconstruction, fifteen brachytherapy catheters were placed into a gel phantom with an embedded catheter fixation framework, with parallel or crossed paths. The MRTR stylet was then inserted sequentially into each catheter. During the removal of the MRTR stylet from within each catheter, a MRTR measurement was performed at 40 Hz to acquire the instantaneous stylet tip position, resulting in a series of three-dimensional (3D) positions along the catheter’s trajectory. A 3D polynomial curve was fit to the tracked positions for each catheter, and equally spaced dwell points were then generated along the curve. High-resolution 3D MRI of the phantom was performed followed by catheter digitization based on the catheter’s imaging artifacts. The catheter trajectory error was characterized in terms of the mean distance between corresponding dwell points in MRTR-generated catheter trajectory and MRI-based catheter digitization. The MRTR-based catheter trajectory reconstruction process was also performed on three gynecologic cancer patients, and then compared with catheter digitization based on MRI and CT. Results: The catheter tip localization error increased as the MRTR stylet moved further off-center and as the stylet’s orientation deviated from the main magnetic field direction. Fifteen catheters’ trajectories were reconstructed by MRTR. Compared with MRI-based digitization, the mean 3D error of MRTR-generated trajectories was 1.5 ± 0.5 mm with an in-plane error of 0.7 ± 0.2 mm and a tip error of 1.7 ± 0.5 mm. MRTR resolved ambiguity in catheter assignment due to crossed catheter paths, which is a common problem in image-based catheter digitization. In the patient studies, the MRTR-generated catheter trajectory was consistent with digitization based on both MRI and CT. Conclusions: The MRTR system provides accurate catheter tip localization and trajectory reconstruction in the MR environment. Relative to the image-based methods, it improves the speed, safety, and reliability of the catheter trajectory reconstruction in interstitial brachytherapy. MRTR may enable in-procedural dosimetric evaluation of implant target coverage.« less
van Eck van der Sluijs, A; Oosterheert, J J; Ekkelenkamp, M B; Hoepelman, I M; Peters, Edgar J G
2012-06-01
Although Gram-negative micro-organisms are frequently associated with catheter-related bloodstream infections, the prognostic value and clinical implication of a positive catheter tip culture with Gram-negative micro-organisms without preceding bacteremia remains unclear. We determined the outcomes of patients with intravascular catheters colonized with these micro-organisms, without preceding positive blood cultures, and identified risk factors for the development of subsequent Gram-negative bacteremia. All patients with positive intravascular catheter tip cultures with Gram-negative micro-organisms at the University Medical Center, Utrecht, The Netherlands, between 2005 and 2009, were retrospectively studied. Patients with Gram-negative bacteremia within 48 h before catheter removal were excluded. The main outcome measure was bacteremia with Gram-negative micro-organisms. Other endpoints were length of the hospital stay, in-hospital mortality, secondary complications of Gram-negative bacteremia, and duration of intensive care admission. A total of 280 catheters from 248 patients were colonized with Gram-negative micro-organisms. Sixty-seven cases were excluded because of preceding positive blood cultures, leaving 213 catheter tips from 181 patients for analysis. In 40 (19%) cases, subsequent Gram-negative bacteremia developed. In multivariate analysis, arterial catheters were independently associated with subsequent Gram-negative bacteremia (odds ratio [OR] = 5.00, 95% confidence interval [CI]: 1.20-20.92), as was selective decontamination of the digestive tract (SDD) (OR = 2.47, 95% CI: 1.07-5.69). Gram-negative bacteremia in patients who received SDD was predominantly caused by cefotaxime (part of the SDD)-resistant organisms. Mortality was significantly higher in the group with subsequent Gram-negative bacteremia (35% versus 20%, OR = 2.12, 95% CI: 1.00-4.49). Patients with a catheter tip colonized with Gram-negative micro-organisms had a high chance of subsequent Gram-negative bacteremia from any cause. This may be clinically relevant, as starting antibiotic treatment pre-emptively in high-risk patients with Gram-negative micro-organisms cultured from arterial intravenous catheters may be beneficial.
Elsharkawy, Hesham; Saasouh, Wael; Patel, Bimal; Babazade, Rovnat
2018-04-01
Currently, no gold standard method exists for localization of an epidural catheter after placement. The technique described in this report uses pulsed-wave Doppler (PWD) ultrasound to identify intrathecal location of an epidural catheter. A thoracic epidural catheter was inserted after multiple trials with inconclusive aspiration and test dose. Ultrasound PWD confirmed no flow in the epidural space and positive flow in the intrathecal space. A fluid aspirate was positive for glucose, reconfirming intrathecal placement. PWD is a potential tool that can be used to locate the tip of an epidural catheter.
Stabille, Débora Miranda Diogo; Filho, Augusto Diogo; Mandim, Beatriz Lemos da Silva; Araújo, Lúcio Borges de; Mesquita, Priscila Miranda Diogo; Jorge, Miguel Tanús
2015-01-01
The increased use of epidural analgesia with catheter leads to the need to demonstrate the safety of this method and know the incidence of catheter colonization, inserted postoperatively for epidural analgesia, and the bacteria responsible for this colonization. From November 2011 to April 2012, patients electively operated and maintained under epidural catheter for postoperative analgesia were evaluated. The catheter tip was collected for semiquantitative and qualitative microbiological analysis. Of 68 cultured catheters, six tips (8.8%) had positive cultures. No patient had superficial or deep infection. The mean duration of catheter use was 43.45hours (18-118) (p=0.0894). The type of surgery (contaminated or uncontaminated), physical status of patients, and surgical time showed no relation with the colonization of catheters. Microorganisms isolated from the catheter tip were Staphylococcus aureus, Pseudomonas aeruginosa and Sphingomonas paucimobilis. Postoperative epidural catheter analgesia, under this study conditions, was found to be low risk for bacterial colonization in patients at surgical wards. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.
Stabille, Débora Miranda Diogo; Diogo Filho, Augusto; Mandim, Beatriz Lemos da Silva; de Araújo, Lúcio Borges; Mesquita, Priscila Miranda Diogo; Jorge, Miguel Tanús
2015-01-01
The increased use of epidural analgesia with catheter leads to the need to demonstrate the safety of this method and know the incidence of catheter colonization, inserted postoperatively for epidural analgesia, and the bacteria responsible for this colonization. From November 2011 to April 2012, patients electively operated and maintained under epidural catheter for postoperative analgesia were evaluated. The catheter tip was collected for semiquantitative and qualitative microbiological analysis. Of 68 cultured catheters, six tips (8.8%) had positive cultures. No patient had superficial or deep infection. The mean duration of catheter use was 43.45 h (18-118) (p=0.0894). The type of surgery (contaminated or uncontaminated), physical status of patients, and surgical time showed no relation with the colonization of catheters. Microorganisms isolated from the catheter tip were Staphylococcus aureus, Pseudomonas aeruginosa and Sphingomonas paucimobilis. Postoperative epidural catheter analgesia, under these study conditions, was found to be low risk for bacterial colonization in patients at surgical wards. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
Evaluation of electrical nerve stimulation for epidural catheter positioning in the dog.
Garcia-Pereira, Fernando L; Sanders, Robert; Shih, Andre C; Sonea, Ioana M; Hauptman, Joseph G
2013-09-01
To evaluate the accuracy of epidural catheter placement at different levels of the spinal cord guided solely by electrical nerve stimulation and resultant segmental muscle contraction. Prospective, experiment. Six male and two female Beagles, age (1 ± 0.17 years) and weight (12.9 ± 1.1 kg). Animals were anesthetized with propofol and maintained with isoflurane. An insulated epidural needle was used to reach the lumbosacral epidural space. A Tsui epidural catheter was inserted and connected to a nerve stimulator (1.0 mA, 0.1 ms, 2 Hz) to assess positioning of the tip at specific spinal cord segments. The catheter was advanced to three different levels of the spinal cord: lumbar (L2-L5), thoracic (T5-T10) and cervical (C4-C6). Subcutaneous needles were previously placed at these spinal levels and the catheter was advanced to match the needle location, guided only by corresponding muscle contractions. Catheter position was verified by fluoroscopy. If catheter tip and needle were at the same vertebral body a score of zero was assigned. When catheter tip was cranial or caudal to the needle, positive or negative numbers, respectively, corresponding to the number of vertebrae between them, were assigned. The mean and standard deviation of the number of vertebrae between catheter tip and needle were calculated to assess accuracy. Results are given as mean ± SD. The catheter position in relation to the needle was within 0.3 ± 2.0 vertebral bodies. Positive predictive values (PPV) were 57%, 83% and 71% for lumbar, thoracic and cervical regions respectively. Overall PPV was 70%. No significant difference in PPV among regions was found. Placement of an epidural catheter at specific spinal levels using electrical nerve stimulation was feasible without radiographic assistance in dogs. Two vertebral bodies difference from the target site may be clinically acceptable when performing segmental epidural regional anesthesia. © 2013 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.
Salimi, Fereshte; Imani, Mohammad Reza; Ghasemi, Navab; Keshavarzian, Amir; Jazi, Amir Hosein Davarpanah
2013-01-01
Background: Long-term tunneled catheters are used for the hemodialysis or chemotherapy in many patients. Proper placement of the catheter tip could reduce early and late catheter related complications. Aim of the present study was to evaluate a new formula for proper placement of tunneled hemodialysis or infusion port device by using an external anatomic landmark. Materials and Methods: A total of 64 adult patients undergoing elective placement of tunneled Central Venous Catheter (CVC) requiring hemodialysis or chemotherapy were enrolled in this prospective study during 2011-2012 in the university hospital. The catheter length to be inserted in the right internal jugular vein (IJV) was calculated by adding two measurements (the shortest straight length between the insertion point of the needle and the suprasternal notch plus and half of sternal length). The catheter position was considered correct if the tip was positioned in the right atrium (RA) or Superior vena cava (SVC)-RA junction. Results: The patients were 55.28 ± 19.85 years of age, weighed 5.78 ± 16.62 kg and were 166.07 ± 10.27 cm tall. Catheters were inserted successfully in 88% of patients (n = 56). Catheter tip positions in the failures were SVC (n = 5), tricuspid valve (n = 2), and right ventricle (n = 1) in our patients. Conclusion: Long-term hemodialysis or port CVC could easily insert in the right IJV by using half of the sternal length as an external land marks among adult patients. PMID:24174941
Development of Active Catheter,Active Guide Wire and Micro Sensor Systems
Haga, Y.; Mineta, T.; Totsu, K.; Makishi, W.; Esashi, M.
2001-01-01
Summary Active catheters and active guide wires which move like a snake have been developed for catheter-based minimally invasive diagnosis and therapy. Communication and control IC chips in the active catheter reduce the number of lead wires for control. The active catheter can be not only bent but also torsioned and extended. An ultra minature fiber-optic pressure sensor; a forward-looking ultrasonic probe and a magnetic position and orientation sensor have been developed for catheters and guide wires. These moving mechanisms and several sensors which are fitted near the tip of the catheter and the guide wire will provide detailed information near the tip and enable delicate and effective catheter intervention. PMID:20663389
Song, Myung Gyu; Seo, Tae-Seok; Kim, Yun Hwan; Cho, Sung Bum; Jung, Euichul; Chung, Hwan Hoon; Lee, Seung Hwa
2016-07-12
To evaluate effectiveness of breast fixation to reduce migration of the catheter tip of a totally implantable venous access port (TIVP) in women. TIVPs were placed in 129 women via the right axillary vein from July 2012 to December 2014, with a final study population of 118 patients (mean age, 55.3 ± 13.8 years; range, 21-91 years). The patients were divided into two groups according to breast fixation during TIVP placement. A total of 56 patients received TIVP placement without breast fixation (Group 1); the remaining 62 received TIVP placement in the supine position after fixation of the ipsilateral breast on the abdominal wall in the sitting position (Group 2). Medical records were retrospectively reviewed for age, weight, height, body mass index, and underlying malignancy. We evaluated the difference in distance ratios between the port chamber and the catheter tip on supine chest and erect chest radiographs, respectively. Statistical analysis was performed using Student's t test. Differences in all parameters between Group 1 and Group 2 were not statistically significant. Mean distance ratio between the port chamber and the catheter tip was 1.95 ± 0.97 in Group 1 and 1.33 ± 0.59 in Group 2. Differences in distance ratios between the port chamber and the catheter tip were statistically significant between Group 1 and Group 2 (p = 0.001). Breast fixation seems to be effective in reducing migration of the port chamber and catheter tip with position changes in female patients during TIVP placement.
Doppler-guided retrograde catheterization system
NASA Astrophysics Data System (ADS)
Frazin, Leon J.; Vonesh, Michael J.; Chandran, Krishnan B.; Khasho, Fouad; Lanza, George M.; Talano, James V.; McPherson, David D.
1991-05-01
The purpose of this study was to investigate a Doppler guided catheterization system as an adjunctive or alternative methodology to overcome the disadvantages of left heart catheterization and angiography. These disadvantages include the biological effects of radiation and the toxic and volume effects of iodine contrast. Doppler retrograde guidance uses a 20 MHz circular pulsed Doppler crystal incorporated into the tip of a triple lumen multipurpose catheter and is advanced retrogradely using the directional flow information provided by the Doppler waveform. The velocity detection limits are either 1 m/second or 4 m/second depending upon the instrumentation. In a physiologic flow model of the human aortic arch, multiple data points revealed a positive wave form when flow was traveling toward the catheter tip indicating proper alignment for retrograde advancement. There was a negative wave form when flow was traveling away from the catheter tip if the catheter was in a branch or bent upon itself indicating improper catheter tip position for retrograde advancement. In a series of six dogs, the catheter was able to be accurately advanced from the femoral artery to the left ventricular chamber under Doppler signal guidance without the use of x-ray. The potential applications of a Doppler guided retrograde catheterization system include decreasing time requirements and allowing safer catheter guidance in patients with atherosclerotic vascular disease and suspected aortic dissection. The Doppler system may allow left ventricular pressure monitoring in the intensive care unit without the need for x-ray and it may allow left sided contrast echocardiography. With pulse velocity detection limits of 4 m/second, this system may allow catheter direction and passage into the aortic root and left ventricle in patients with aortic stenosis. A modification of the Doppler catheter may include transponder technology which would allow precise catheter tip localization once the catheter tip is placed in the aortic root. Such technology may conceivably assist in allowing selective coronary catheterization. These studies have demonstrated that Doppler guided retrograde catheterization provides an accurate method to catheterization the aortic root and left ventricular chamber without x-ray. In humans, it may prove useful in a variety of settings including the development of invasive ultrasonic diagnostic and therapeutic technology.
Bouza, E; San Juan, R; Muñoz, P; Pascau, J; Voss, A; Desco, M
2004-09-01
The laboratory workload, microbiological techniques and aetiology of catheter-related infections in European hospitals are mostly unknown. The present study (ESGNI-005) comprised a 1-day (22 October 2001), laboratory-based, point-prevalence survey based on a questionnaire completed by microbiology laboratories in European (European Union (EU) and non-EU) hospitals. Also included were questions requesting retrospective information for the year 2000. In total, 151 hospitals from 26 European countries participated, of which 78.1% were teaching institutions. Overall, the estimated population served by these institutions was 121,363,800, and the estimated number of admissions during 2000 was 6,712,050. The total number of catheter tips processed during 2000 was 142,727, or 21/1,000 admissions, of which 23.7% were considered to be positive in the institutions using semiquantitative or quantitative techniques. Overall, EU centres received significantly more catheter tip samples/1,000 admissions and had a significantly higher rate of 'positivity' (p < 0.0001) than non-EU centres. Of the institutions surveyed, 11.4% (7.2% in EU countries and 23.7% in non-EU countries; p 0.04) used only qualitative techniques for catheter tip sample processing. On the day of the study, 167 microorganisms were recovered from significant catheter tip cultures (122 patients), of which Gram-positive bacteria represented 70.7%, Gram-negative bacteria 22.2%, and yeasts 7.2%. The five most common microorganisms were coagulase-negative staphylococci, Staphylococcus aureus, Candida spp., Enterococcus spp. and Pseudomonas spp. Overall, 19% of catheter tip cultures were polymicrobial. In the case of S. aureus, 40% of isolates were resistant to oxacillin, as were 63.4% of coagulase-negative staphylococcus isolates. Of 37 Gram-negative isolates, 35% were resistant to cefotaxime, 31% to ceftazidime, and 27% to ciprofloxacin. Imipenem and cefepime had the lowest reported rates of resistance (11%).
Amir, Rabia; Knio, Ziyad O; Mahmood, Feroze; Oren-Grinberg, Achikam; Leibowitz, Akiva; Bose, Ruma; Shaefi, Shahzad; Mitchell, John D; Ahmed, Muneeb; Bardia, Amit; Talmor, Daniel; Matyal, Robina
2017-07-01
Although real-time ultrasound guidance during central venous catheter insertion has become a standard of care, postinsertion chest radiograph remains the gold standard to confirm central venous catheter tip position and rule out associated lung complications like pneumothorax. We hypothesize that a combination of transthoracic echocardiography and lung ultrasound is noninferior to chest radiograph when used to accurately assess central venous catheter positioning and screen for pneumothorax. All operating rooms and surgical and trauma ICUs at the institution. Single-center, prospective noninferiority study. Patients receiving ultrasound-guided subclavian or internal jugular central venous catheters. During ultrasound-guided central venous catheter placement, correct positioning of central venous catheter was accomplished by real-time visualization of the guide wire and positive right atrial swirl sign using the subcostal four-chamber view. After insertion, pneumothorax was ruled out by the presence of lung sliding and seashore sign on M-mode. Data analysis was done for 137 patients. Chest radiograph ruled out pneumothorax in 137 of 137 patients (100%). Lung ultrasound was performed in 123 of 137 patients and successfully screened for pneumothorax in 123 of 123 (100%). Chest radiograph approximated accurate catheter tip position in 136 of 137 patients (99.3%). Adequate subcostal four-chamber views could not be obtained in 13 patients. Accurate positioning of central venous catheter with ultrasound was then confirmed in 121 of 124 patients (97.6%) as described previously. Transthoracic echocardiography and lung ultrasound are noninferior to chest x-ray for screening of pneumothorax and accurate central venous catheter positioning. Thus, the point of care use of ultrasound can reduce central venous catheter insertion to use time, exposure to radiation, and improve patient safety.
NASA Astrophysics Data System (ADS)
Iovea, M.; Creed, J.; Perin, E.; Neagu, M.; Mateiasi, G.
2009-02-01
The aim of this study was to conduct a preliminary check of a new method for measuring the 3D catheter position based on only one X-Ray view (image) and a simple pre-calibration procedure for catheters that could be equipped with high-opacity equal-spaced markers. The application chosen for this experiment is the targeted delivery of cell based therapeutic via a transendocardial retrograde approach into the left ventricle. This approach has shown promising therapeutic retention data when injected directly into the myocardial tissue, but lacks in the ability of the user to confidently manipulate the catheter within the left ventricle cavity space under traditional fluoroscopic guidance using a needle based catheter. The need for a new technique arose from the potential for increased safety and therapeutic efficacy by improving the targeting of the agent. The new technique, destined for Image guided catheter navigation systems for cardiac interventions, is based on a measurement of the marker's size and distance between them and followed by a comparison with the referenced catheter position. Preliminary experiments made with a simple phantom are presented, emphasizing the ability of the new technique in measuring the markers and the catheter tip 3D position. An overall maximum error in positioning markers and catheter tip below 12% has been obtained, yielding a promising result for continuing the future work of improving the algorithm accuracy.
Wirsing, Melanie; Schummer, Claudia; Neumann, Rotraud; Steenbeck, Jörg; Schmidt, Peter; Schummer, Wolfram
2008-09-01
Traditionally, the positioning of central venous catheters (CVCs) outside the right atrium (RA) in patients receiving intensive care is determined by surrogate landmarks on bedside chest radiographs (CXRs). The validity of this method was examined by comparing readings of radiologists with the results of transesophageal echocardiography (TEE). Prospective study at university hospital. Two hundred thirteen adults scheduled for cardiothoracic surgery were randomized to right or left internal jugular vein catheterization under ECG guidance. One senior radiologist and two radiologists in training independently read the CXRs, and determined whether the CVC tip ended in the RA and measured the vertical distance from the CVC tip to the carina (TC-distance). Two hundred twelve CVC tips could be identified by TEE. Only left-sided CVCs (n = 5) ended in the upper RA (2.4%). Three of those patients were shorter than 160 cm. Specificity was 94% for senior radiologist, 44% for the first radiologist in training, and 60% for the second radiologist in training. The TC-distance of intraatrial catheters was 39, 55, 59, 80, and 83 mm, respectively. Thus, a TC-distance < or = 55 mm ensured extraatrial tip position in four of five intraatrial CVCs (80%, p = 0.002). The TC-distance of extraatrial catheters ranged from - 26 to 102 mm. Reading of a bedside CXR alone is not very accurate to identify intraatrial CVC tip position. TC-distance is a helpful marker, and its specificity is as good as that of an experienced radiologist if a cutoff value of 55 mm is chosen.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lucey, Brian; Varghese, Jose C.; Haslam, Philip
1999-09-15
Purpose: To study the cost and impact on patient management of the routine performance of chest radiographs in patients undergoing imaged-guided central venous catheter insertion. Methods: Six hundred and twenty-one catheters placed in 489 patients over a 42-month period formed the study group. Catheters were placed in the right internal jugular vein (425), left internal jugular vein (133), and subclavian veins (63). At the end of the procedure fluoroscopy was used to assess catheter position and check for complications. A postprocedural chest radiograph was obtained in all patients. Results: Postprocedural chest fluoroscopy showed no evidence of pneumothorax, hemothorax, or mediastinalmore » hematoma. Inappropriate catheter tip position or catheter kinks were noted with 90 catheters. These problems were all corrected while the patient was on the interventional table. Postprocedural chest radiographs showed no complications but proximal catheter tip migration was noted in six of 621 catheters (1%). These latter six catheters required further manipulation. The total technical and related charges for the postprocedural chest radiographs in this series were estimated at Pounds 15,525. Conclusion: Postprocedural chest radiographs after image-guided central venous catheter insertion are not routinely required. A postprocedural chest radiograph can be performed on a case-by-case basis at the discretion of the interventional radiologist.« less
Remote Navigation for Complex Arrhythmia
Suman-Horduna, Irina; Babu-Narayan, Sonya V; Ernst, Sabine
2013-01-01
Magnetic navigation has been established as an alternative to conventional, manual catheter navigation for invasive electrophysiology interventions about a decade ago. Besides the obvious advantage of radiation protection for the operator who is positioned remotely from the patient, there are additional benefits of steering the tip of a very floppy catheter. This manuscript reviews the published evidence from simple arrhythmias in patients with normal cardiac anatomy to the most complex congenital heart disease. This progress was made possible by the introduction of improved catheters and most importantly irrigated-tip electrodes. PMID:26835041
Lim, Bernard; Venkatachalam, Kalpathi L; Jahangir, Arshad; Johnson, Susan B; Asirvatham, Samuel J
2008-08-01
Thromboembolism resulting from coagulum formation on the catheter and electrode surfaces is a serious complication with radiofrequency ablation procedures for heart rhythm disorders. Why coagulum occurs despite therapeutic heparinization is unclear. In this report, we demonstrate a novel approach to minimize coagulum formation based on the electromolecular characteristics of fibrinogen. Atomic force microscopy was used to establish that fibrinogen deposited on surfaces underwent conformational changes that resulted in spontaneous clot formation. We then immersed ablation catheters that were uncharged, negatively, or positively charged in heparinized blood for 30 minutes and noted the extent of clot formation. In separate experiments, ablation catheters were sutured to the ventricle of an excised porcine heart immersed in whole, heparinized blood and radiofrequency ablation performed for 5 minutes with and without charge delivered to the catheter tips. Electron microscopy of the catheter tips showed surface coverage of fibrin clot of the catheter to be 33.8% for negatively charged catheters, compared with 84.7% (P = 0.01) in noncharged catheters. There was no significant difference in surface coverage of fibrin clot between positively charged catheters (93.8%) and noncharged catheters (84.7%, P = ns). In contrast, the thickness of surface clot coverage for positively charged catheters was 87.5%, compared with 28.45% (P= 0.03) for noncharged catheters and 11.25% (P = 0.03) for negatively charged catheters, compared with noncharged catheters. We describe a novel method of placing negative charge on electrodes during ablation that reduced coagulum formation. This may decrease thromboembolism-related complications with radiofrequency ablation procedures.
Zhao, Ruiyi; Chen, Chunfang; Jin, Jingfen; Sharma, Komal; Jiang, Nan; Shentu, Yingqin; Wang, Xingang
2016-06-01
The use of peripherally inserted central catheters (PICCs) provides important central venous accesses for clinical treatments, tests and monitoring. Compared with the traditional methods, intracardiac electrocardiogram (ECG)-guided method has the potential to guide more accurate tip positioning of PICCs. This study aimed to clinically evaluate the effectiveness of an intracardiac ECG to guide the tip positioning by monitoring characteristic P-wave changes. In this study, eligible patients enrolled September 2011 to May 2012 according to the inclusion and exclusion criteria received the catheterization monitored by intracardiac ECG. Then chest radiography was performed to check the catheter position. The results revealed that, with 117 eligible patients, all bar one patient who died (n = 116) completed the study, including 60 males and 56 females aged 51.2 ± 15.1 years. Most (n = 113, > 97%) had characteristic P-wave changes. The intracardiac ECG-guided positioning procedure achieved correct placement for 112 patients (96.56%), demonstrating 99.12% sensitivity and 100% specificity. In conclusion, the intracardiac ECG can be a promising technique to guide tip positioning of PICCs. However, since the sample size in this study is limited, more experience and further study during clinical practice are needed to demonstrate achievement of optimal catheterization outcomes. © 2015 John Wiley & Sons Australia, Ltd.
Design and Control of a Mechatronic Tracheostomy Tube for Automated Tracheal Suctioning.
Do, Thanh Nho; Seah, Tian En Timothy; Phee, Soo Jay
2016-06-01
Mechanical ventilation is required to aid patients with breathing difficulty to breathe more comfortably. A tracheostomy tube inserted through an opening in the patient neck into the trachea is connected to a ventilator for suctioning. Currently, nurses spend millions of person-hours yearly to perform this task. To save significant person-hours, an automated mechatronic tracheostomy system is needed. This system allows for relieving nurses and other carers from the millions of person-hours spent yearly on tracheal suctioning. In addition, it will result in huge healthcare cost savings. We introduce a novel mechatronic tracheostomy system including the development of a long suction catheter, automatic suctioning mechanisms, and relevant control approaches to perform tracheal suctioning automatically. To stop the catheter at a desired position, two approaches are introduced: 1) Based on the known travel length of the catheter tip; 2) Based on a new sensing device integrated at the catheter tip. It is known that backlash nonlinearity between the suction catheter and its conduit as well as in the gear system of the actuator are unavoidable. They cause difficulties to control the exact position of the catheter tip. For the former case, we develop an approximate model of backlash and a direct inverse scheme to enhance the system performances. The scheme does not require any complex inversions of the backlash model and allows easy implementations. For the latter case, a new sensing device integrated into the suction catheter tip is developed and backlash compensation controls are avoided. Automated suctioning validations are successfully carried out on the proposed experimental system. Comparisons and discussions are also introduced. The results demonstrate a significant contribution and potential benefits to the mechanical ventilation areas.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jaber, Mohammad R., E-mail: raffatj@msn.co; Thomson, Matthew J.; Smith, Douglas C.
We describe percutaneous, translumbar placement of a 14-Fr dialysis catheter into an ascending lumbar vein to achieve tip position in an enlarged azygos vein. The patient had thrombosis of all traditional vascular sites, as well as the inferior vena cava. This catheter functioned well for 7 months before fatal catheter-related infection developed.
Endoscopic-Assisted Burr Hole Reservoir and Ventricle Catheter Placement.
Antes, Sebastian; Tschan, Christoph A; Heckelmann, Michael; Salah, Mohamed; Senger, Sebastian; Linsler, Stefan; Oertel, Joachim
2017-05-01
Accurate positioning of a ventricle catheter is of utmost importance. Various techniques to ensure optimal positioning have been described. Commonly, after catheter placement, additional manipulation is necessary to connect a burr hole reservoir or shunt components. This manipulation can lead to accidental catheter dislocation and should be avoided. Here, we present a new technique that allows direct endoscopic insertion of a burr hole reservoir with an already mounted ventricle catheter. Before insertion, the ventricle catheter was slit at the tip, shortened to the correct length, and connected to the special burr hole reservoir. An intracatheter endoscope was then advanced through the reservoir and the connected catheter. This assemblage allowed using the endoscope as a stylet for shielded ventricular puncture. To confirm correct placement of the ventricle catheter, the endoscope was protruded a few millimeters beyond the catheter tip for inspection. The new technique was applied in 12 procedures. The modified burr hole reservoir was inserted for first-time ventriculoperitoneal shunting (n = 1), cerebrospinal fluid withdrawals and drug administration (n = 2), or different stenting procedures (n = 9). Optimal positioning of the catheter was achieved in 11 of 12 cases. No subcutaneous cerebrospinal fluid collection or fluid leakage through the wound occurred. No parenchymal damage or bleeding appeared. The use of the intracatheter endoscope combined with the modified burr hole reservoir provides a sufficient technique for accurate and safe placement. Connecting the ventricle catheter to the reservoir before the insertion reduces later manipulation and accidental dislocation of the catheter. Copyright © 2017 Elsevier Inc. All rights reserved.
Effectiveness of electrocardiographic guidance in CVAD tip placement.
Walker, Graham; Chan, Raymond J; Alexandrou, Evan; Webster, Joan; Rickard, Claire
International standard practice for the correct confirmation of the central venous access device is the chest X-ray. The intracavitary electrocardiogram-based insertion method is radiation-free, and allows real-time placement verification, providing immediate treatment and reduced requirement for post-procedural repositioning. Relevant databases were searched for prospective randomised controlled trials (RCTs) or quasi RCTs that compared the effectiveness of electrocardiogram-guided catheter tip positioning with placement using surface-anatomy-guided insertion plus chest X-ray confirmation. The primary outcome was accurate catheter tip placement. Secondary outcomes included complications, patient satisfaction and costs. Five studies involving 729 participants were included. Electrocardiogram-guided insertion was more accurate than surface anatomy guided insertion (odds ratio: 8.3; 95% confidence interval (CI) 1.38; 50.07; p=0.02). There was a lack of reporting on complications, patient satisfaction and costs. The evidence suggests that intracavitary electrocardiogram-based positioning is superior to surface-anatomy-guided positioning of central venous access devices, leading to significantly more successful placements. This technique could potentially remove the requirement for post-procedural chest X-ray, especially during peripherally inserted central catheter (PICC) line insertion.
Harde, Minal; Bhadade, Rakesh; Iyer, Hemlata; Jatale, Amol; Tiwatne, Sagar
2016-02-01
Infection is a potentially serious complication of epidural analgesia and with an increase in its use in wards there is a necessity to demonstrate its safety. We aimed to compare the incidence of colonization of epidural catheters retained for short duration (for 48 h) postoperative analgesia in postanesthesia care unit and wards. It was a prospective observational study done in a tertiary care teaching public hospital over a period of 2 years and included 400 patients with 200 each belonged to two groups PACU and ward. We also studied epidural tip culture pattern, skin swab culture at the entry point of the catheter, their relation to each other and whether colonization is equivalent to infection. Data were analyzed using statistical software GraphPad. Overall positive tip culture was 6% (24), of them 7% (14) were from PACU and 5% (10) were from ward (P = 0.5285). Positive skin swab culture was 38% (150), of them 20% (80) were from PACU and 18% (70) were from ward (P = 0.3526). The relation between positive tip culture and positive skin swab culture in same patients is extremely significant showing a strong linear relationship (95% confidence interval = 0.1053-0.2289). The most common microorganism isolated was Staphylococcus epidermidis. No patient had signs of local or epidural infection. There is no difference in the incidence of epidural catheter tip culture and skin swab culture of patients from the general ward and PACU. Epidural analgesia can be administered safely for 48 h in general wards without added risk of infection. The presence of positive tip culture is not a predictor of epidural space infection, and colonization is not equivalent to infection; hence, routine culture is not needed. Bacterial migration from the skin along the epidural track is the most common mode of bacterial colonization; hence, strict asepsis is necessary.
Robotic positioning of standard electrophysiology catheters: a novel approach to catheter robotics.
Knight, Bradley; Ayers, Gregory M; Cohen, Todd J
2008-05-01
Robotic systems have been developed to manipulate and position electrophysiology (EP) catheters remotely. One limitation of existing systems is their requirement for specialized catheters or sheaths. We evaluated a system (Catheter Robotics Remote Catheter Manipulation System [RCMS], Catheter Robotics, Inc., Budd Lake, New Jersey) that manipulates conventional EP catheters placed through standard introducer sheaths. The remote controller functions much like the EP catheter handle, and the system permits repeated catheter disengagement for manual manipulation without requiring removal of the catheter from the body. This study tested the hypothesis that the RCMS would be able to safely and effectively position catheters at various intracardiac sites and obtain thresholds and electrograms similar to those obtained with manual catheter manipulation. Two identical 7 Fr catheters (Blazer II; Boston Scientific Corp., Natick, Massachusetts) were inserted into the right femoral veins of 6 mongrel dogs through separate, standard 7 Fr sheaths. The first catheter was manually placed at a right ventricular endocardial site. The second catheter handle was placed in the mating holder of the RCMS and moved to approximately the same site as the first catheter using the Catheter Robotics RCMS. The pacing threshold was determined for each catheter. This sequence was performed at 2 right atrial and 2 right ventricular sites. The distance between the manually and robotically placed catheters tips was measured, and pacing thresholds and His-bundle recordings were compared. The heart was inspected at necropsy for signs of cardiac perforation or injury. Compared to manual positioning, remote catheter placement produced the same pacing threshold at 7/24 sites, a lower threshold at 11/24 sites, and a higher threshold at only 6/24 sites (p > 0.05). The average distance between catheter tips was 0.46 +/- 0.32 cm (median 0.32, range 0.13-1.16 cm). There was no difference between right atrial and right ventricular sites (p > 0.05). His-bundle electrograms were equal in amplitude and timing. Further, the remote navigation catheter was able to be disengaged, manually manipulated, then reengaged in the robot without issue. There was no evidence of perforation. The Catheter Robotics remote catheter manipulation system, which uses conventional EP catheters and introducer sheaths, appears to be safe and effective at directing EP catheters to intracardiac sites and achieving pacing thresholds and electrograms equivalent to manually placed catheters. Further clinical studies are needed to confirm these observations.
Post-procedural evaluation of catheter contact force characteristics
NASA Astrophysics Data System (ADS)
Koch, Martin; Brost, Alexander; Kiraly, Atilla; Strobel, Norbert; Hornegger, Joachim
2012-03-01
Minimally invasive catheter ablation of electric foci, performed in electrophysiology labs, is an attractive treatment option for atrial fibrillation (AF) - in particular if drug therapy is no longer effective or tolerated. There are different strategies to eliminate the electric foci inducing the arrhythmia. Independent of the particular strategy, it is essential to place transmural lesions. The impact of catheter contact force on the generated lesion quality has been investigated recently, and first results are promising. There are different approaches to measure catheter-tissue contact. Besides traditional haptic feedback, there are new technologies either relying on catheter tip-to-tissue contact force or on local impedance measurements at the tip of the catheter. In this paper, we present a novel tool for post-procedural ablation point evaluation and visualization of contact force characteristics. Our method is based on localizing ablation points set during AF ablation procedures. The 3-D point positions are stored together with lesion specific catheter contact force (CF) values recorded during the ablation. The force records are mapped to the spatial 3-D positions, where the energy has been applied. The tracked positions of the ablation points can be further used to generate a 3-D mesh model of the left atrium (LA). Since our approach facilitates visualization of different force characteristics for post-procedural evaluation and verification, it has the potential to improve outcome by highlighting areas where lesion quality may be less than desired.
NASA Astrophysics Data System (ADS)
Dunkerley, David A. P.; Funk, Tobias; Speidel, Michael A.
2016-03-01
Scanning-beam digital x-ray (SBDX) is an inverse geometry x-ray fluoroscopy system capable of tomosynthesis-based 3D catheter tracking. This work proposes a method of dose-reduced 3D tracking using dynamic electronic collimation (DEC) of the SBDX scanning x-ray tube. Positions in the 2D focal spot array are selectively activated to create a regionof- interest (ROI) x-ray field around the tracked catheter. The ROI position is updated for each frame based on a motion vector calculated from the two most recent 3D tracking results. The technique was evaluated with SBDX data acquired as a catheter tip inside a chest phantom was pulled along a 3D trajectory. DEC scans were retrospectively generated from the detector images stored for each focal spot position. DEC imaging of a catheter tip in a volume measuring 11.4 cm across at isocenter required 340 active focal spots per frame, versus 4473 spots in full-FOV mode. The dose-area-product (DAP) and peak skin dose (PSD) for DEC versus full field-of-view (FOV) scanning were calculated using an SBDX Monte Carlo simulation code. DAP was reduced to 7.4% to 8.4% of the full-FOV value, consistent with the relative number of active focal spots (7.6%). For image sequences with a moving catheter, PSD was 33.6% to 34.8% of the full-FOV value. The root-mean-squared-deviation between DEC-based 3D tracking coordinates and full-FOV 3D tracking coordinates was less than 0.1 mm. The 3D distance between the tracked tip and the sheath centerline averaged 0.75 mm. Dynamic electronic collimation can reduce dose with minimal change in tracking performance.
Semi-automated location identification of catheters in digital chest radiographs
NASA Astrophysics Data System (ADS)
Keller, Brad M.; Reeves, Anthony P.; Cham, Matthew D.; Henschke, Claudia I.; Yankelevitz, David F.
2007-03-01
Localization of catheter tips is the most common task in intensive care unit imaging. In this work, catheters appearing in digital chest radiographs acquired by portable chest x-rays were tracked using a semi-automatic method. Due to the fact that catheters are synthetic objects, its profile does not vary drastically over its length. Therefore, we use forward looking registration with normalized cross-correlation in order to take advantage of a priori information of the catheter profile. The registration is accomplished with a two-dimensional template representative of the catheter to be tracked generated using two seed points given by the user. To validate catheter tracking with this method, we look at two metrics: accuracy and precision. The algorithms results are compared to a ground truth established by catheter midlines marked by expert radiologists. Using 12 objects of interest comprised of naso-gastric, endo-tracheal tubes, and chest tubes, and PICC and central venous catheters, we find that our algorithm can fully track 75% of the objects of interest, with a average tracking accuracy and precision of 85.0%, 93.6% respectively using the above metrics. Such a technique would be useful for physicians wishing to verify the positioning of catheter tips using chest radiographs.
NASA Astrophysics Data System (ADS)
Mefleh, Fuad N.; Baker, G. Hamilton; Kwartowitz, David M.
2014-03-01
In our previous work we presented a novel image-guided surgery (IGS) system, Kit for Navigation by Image Focused Exploration (KNIFE).1,2 KNIFE has been demonstrated to be effective in guiding mock clinical procedures with the tip of an electromagnetically tracked catheter overlaid onto a pre-captured bi-plane fluoroscopic loop. Representation of the catheter in KNIFE differs greatly from what is captured by the fluoroscope, due to distortions and other properties of fluoroscopic images. When imaged by a fluoroscope, catheters can be visualized due to the inclusion of radiopaque materials (i.e. Bi, Ba, W) in the polymer blend.3 However, in KNIFE catheter location is determined using a single tracking seed located in the catheter tip that is represented as a single point overlaid on pre-captured fluoroscopic images. To bridge the gap in catheter representation between KNIFE and traditional methods we constructed a catheter with five tracking seeds positioned along the distal 70 mm of the catheter. We have currently investigated the use of four spline interpolation methods for estimation of true catheter shape and have assesed the error in their estimation of true catheter shape. In this work we present a method for the evaluation of interpolation algorithms with respect to catheter shape determination.
Biophysics and clinical utility of irrigated-tip radiofrequency catheter ablation.
Houmsse, Mahmoud; Daoud, Emile G
2012-01-01
Catheter ablation by radiofrequency (RF) energy has successfully eliminated cardiac tachyarrhythmias. RF ablation lesions are created by thermal energy. Electrode catheters with 4-mm-tips have been adequate to ablate arrhythmias located near the endocardium; however, the 4-mm-tip electrode does not readily ablate deeper tachyarrhythmia substrate. With 8- and 10-mm-tip RF electrodes, ablation lesions were larger; yet, these catheters are associated with increased risk for coagulum, char and thrombus formation, as well as myocardial steam rupture. Cooled-tip catheter technology was designed to cool the electrode tip, prevent excessive temperatures at the electrode tip-tissue interface, and thus allow continued delivery of RF current into the surrounding tissue. This ablation system creates larger and deeper ablation lesions and minimizes steam pops and thrombus formation. The purpose of this article is to review cooled-tip RF ablation biophysics and outcomes of clinical studies as well as to discuss future technological improvements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Damato, A; Viswanathan, A; Cormack, R
2015-06-15
Purpose: To evaluate the feasibility of brachytherapy catheter localization through use of an EMT and 3D image set. Methods: A 15-catheter phantom mimicking an interstitial implantation was built and CT-scanned. Baseline catheter reconstruction was performed manually. An EMT was used to acquire the catheter coordinates in the EMT frame of reference. N user-identified catheter tips, without catheter number associations, were used to establish registration with the CT frame of reference. Two algorithms were investigated: brute-force registration (BFR), in which all possible permutation of N identified tips with the EMT tips were evaluated; and signature-based registration (SBR), in which a distancemore » matrix was used to generate a list of matching signatures describing possible N-point matches with the registration points. Digitization error (average of the distance between corresponding EMT and baseline dwell positions; average, standard deviation, and worst-case scenario over all possible registration-point selections) and algorithm inefficiency (maximum number of rigid registrations required to find the matching fusion for all possible selections of registration points) were calculated. Results: Digitization errors on average <2 mm were observed for N ≥5, with standard deviation <2 mm for N ≥6, and worst-case scenario error <2 mm for N ≥11. Algorithm inefficiencies were: N = 5, 32,760 (BFR) and 9900 (SBR); N = 6, 360,360 (BFR) and 21,660 (SBR); N = 11, 5.45*1010 (BFR) and 12 (SBR). Conclusion: A procedure was proposed for catheter reconstruction using EMT and only requiring user identification of catheter tips without catheter localization. Digitization errors <2 mm were observed on average with 5 or more registration points, and in any scenario with 11 or more points. Inefficiency for N = 11 was 9 orders of magnitude lower for SBR than for BFR. Funding: Kaye Family Award.« less
Comparing deflection measurements of a magnetically steerable catheter using optical imaging and MRI
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lillaney, Prasheel, E-mail: Prasheel.Lillaney@ucsf.edu; Caton, Curtis; Martin, Alastair J.
2014-02-15
Purpose: Magnetic resonance imaging (MRI) is an emerging modality for interventional radiology, giving clinicians another tool for minimally invasive image-guided interventional procedures. Difficulties associated with endovascular catheter navigation using MRI guidance led to the development of a magnetically steerable catheter. The focus of this study was to mechanically characterize deflections of two different prototypes of the magnetically steerable catheterin vitro to better understand their efficacy. Methods: A mathematical model for deflection of the magnetically steerable catheter is formulated based on the principle that at equilibrium the mechanical and magnetic torques are equal to each other. Furthermore, two different image basedmore » methods for empirically measuring the catheter deflection angle are presented. The first, referred to as the absolute tip method, measures the angle of the line that is tangential to the catheter tip. The second, referred to the base to tip method, is an approximation that is used when it is not possible to measure the angle of the tangent line. Optical images of the catheter deflection are analyzed using the absolute tip method to quantitatively validate the predicted deflections from the mathematical model. Optical images of the catheter deflection are also analyzed using the base to tip method to quantitatively determine the differences between the absolute tip and base to tip methods. Finally, the optical images are compared to MR images using the base to tip method to determine the accuracy of measuring the catheter deflection using MR. Results: The optical catheter deflection angles measured for both catheter prototypes using the absolute tip method fit very well to the mathematical model (R{sup 2} = 0.91 and 0.86 for each prototype, respectively). It was found that the angles measured using the base to tip method were consistently smaller than those measured using the absolute tip method. The deflection angles measured using optical data did not demonstrate a significant difference from the angles measured using MR image data when compared using the base to tip method. Conclusions: This study validates the theoretical description of the magnetically steerable catheter, while also giving insight into different methods and modalities for measuring the deflection angles of the prototype catheters. These results can be used to mechanically model future iterations of the design. Quantifying the difference between the different methods for measuring catheter deflection will be important when making deflection measurements in future studies. Finally, MR images can be used to reliably measure deflection angles since there is no significant difference between the MR and optical measurements.« less
Discriminating Tissue Stiffness with a Haptic Catheter: Feeling the Inside of the Beating Heart.
Kesner, Samuel B; Howe, Robert D
2011-01-01
Catheter devices allow physicians to access the inside of the human body easily and painlessly through natural orifices and vessels. Although catheters allow for the delivery of fluids and drugs, the deployment of devices, and the acquisition of the measurements, they do not allow clinicians to assess the physical properties of tissue inside the body due to the tissue motion and transmission limitations of the catheter devices, including compliance, friction, and backlash. The goal of this research is to increase the tactile information available to physicians during catheter procedures by providing haptic feedback during palpation procedures. To accomplish this goal, we have developed the first motion compensated actuated catheter system that enables haptic perception of fast moving tissue structures. The actuated catheter is instrumented with a distal tip force sensor and a force feedback interface that allows users to adjust the position of the catheter while experiencing the forces on the catheter tip. The efficacy of this device and interface is evaluated through a psychophyisical study comparing how accurately users can differentiate various materials attached to a cardiac motion simulator using the haptic device and a conventional manual catheter. The results demonstrate that haptics improves a user's ability to differentiate material properties and decreases the total number of errors by 50% over the manual catheter system.
Steerable catheter microcoils for interventional MRI reducing resistive heating.
Bernhardt, Anthony; Wilson, Mark W; Settecase, Fabio; Evans, Leland; Malba, Vincent; Martin, Alastair J; Saeed, Maythem; Roberts, Timothy P L; Arenson, Ronald L; Hetts, Steven W
2011-03-01
The aims of this study were to assess resistive heating of microwires used for remote catheter steering in interventional magnetic resonance imaging and to investigate the use of alumina to facilitate heat transfer to saline flowing in the catheter lumen. A microcoil was fabricated using a laser lathe onto polyimide-tipped or alumina-tipped endovascular catheters. In vitro testing was performed on a 1.5-T magnetic resonance system using a vessel phantom, body radiofrequency coil, and steady-state pulse sequence. Resistive heating was measured with water flowing over a polyimide-tip catheter or saline flowing through the lumen of an alumina-tip catheter. Preliminary in vivo testing in porcine common carotid arteries was conducted with normal blood flow or after arterial ligation when current was applied to an alumina-tip catheter for up to 5 minutes. After application of up to 1 W of direct current power, clinically significant temperature increases were noted with the polyimide-tip catheter: 23°C/W at zero flow, 13°C/W at 0.28 cm(3)/s, and 7.9°C/W at 1 cm(3)/s. Using the alumina-tip catheter, the effluent temperature rise using the lowest flow rate (0.12 cm(3)/s) was 2.3°C/W. In vivo testing demonstrated no thermal injury to vessel walls at normal and zero arterial flow. Resistive heating in current carrying wire pairs can be dissipated by saline coolant flowing within the lumen of a catheter tip composed of material that facilitates heat transfer. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.
Magnetic Catheter Manipulation in the Interventional MRI Environment
Wilson, Mark W.; Martin, Alastair B.; Lillaney, Prasheel; Losey, Aaron D.; Yee, Erin J.; Bernhardt, Anthony; Malba, Vincent; Evans, Lee; Sincic, Ryan; Saeed, Maythem; Arenson, Ronald L.; Hetts, Steven W.
2013-01-01
Purpose To evaluate deflection capability of a prototype endovascular catheter, which is remotely magnetically steerable, for use in the interventional MRI environment. Materials and Methods Copper coils were mounted on the tips of commercially available 2.3 – 3.0 Fr microcatheters. The coils were fabricated in a novel manner by plasma vapor deposition of a copper layer followed by laser lithography of the layer into coils. Orthogonal helical (solenoid) and saddle-shaped (Helmholtz) coils were mounted on a single catheter tip. Microcatheters were tested in water bath phantoms in a 1.5T clinical MRI scanner, with variable simultaneous currents applied to the coils. Catheter tip deflection was imaged in the axial plane utilizing a “real-time” steady-state free precession (SSFP) MRI sequence. Degree of deflection and catheter tip orientation were measured for each current application. Results The catheter tip was clearly visible in the longitudinal and axial planes. Magnetic field artifacts were visible when the orthogonal coils at the catheter tip were energized. Variable amounts of current applied to a single coil demonstrated consistent catheter deflection in all water bath experiments. Changing current polarity reversed the observed direction of deflection, whereas current applied to two different coils resulted in deflection represented by the composite vector of individual coil activations. Microcatheter navigation through the vascular phantom was successful through control of applied current to one or more coils. Conclusion Controlled catheter deflection is possible with laser lithographed multi-axis coil tipped catheters in the MRI environment. PMID:23707097
RF induced energy for partially implanted catheters: a computational study
Lucano, Elena; Liberti, Micaela; Lloyd, Tom; Apollonio, Francesca; Wedan, Steve; Kainz, Wolfgang; Angelone, Leonardo M.
2018-01-01
Magnetic Resonance Imaging (MRI) is a radiological imaging technique widely used in clinical practice. MRI has been proposed to guide the catheters for interventional procedures, such as cardiac ablation. However, there are risks associated with this procedure, such as RF-induced heating of tissue near the catheters. The aim of this study is to develop a quantitative RF-safety method for patients with partially implanted leads at 64 MHz. RF-induced heating is related to the electric field incident along the catheter, which in turns depends on several variables, including the position of the RF feeding sources and the orientation of the polarization, which are however often unknown. This study evaluates the electric field profile along the lead trajectory using simulations with an anatomical human model landmarked at the heart. The energy absorbed in the volume near the tip of ageneric partially implanted lead was computed for all source positions and field orientation. The results showed that varying source positions and field orientation may result in changes of up to 18% for the E-field magnitude and up to 60% for the 10g-averaged specific absorption rate (SAR) in the volume surrounding the tip of the lead. PMID:28268553
Steffen, Peter; Seeling, Wulf; Essig, Andreas; Stiepan, Erika; Rockemann, Michael Georg
2004-03-01
To investigate the frequency of bacterial colonization of epidural catheters used for postoperative pain treatment longer than 24 hours in abdominal, thoracic, or trauma surgery patients. Retrospective study. Intermediate care facility and general ward of a university hospital. 502 patients who received epidural catheters after abdominal, thoracic, or vascular surgery at our institution from January 1996 to December 2000. Placement of an epidural catheter, which was used for postoperative pain treatment, for more than 24 hours. The puncture site dressing included saturation each day with povidone-iodine. Microbiologic monitoring of epidural catheter tips and daily examination of puncture sites with regard to signs of inflammation took place. Four times daily patients were examined to check adequacy of pain treatment and neurologic deficits. Catheter tip cultures were positive in 29 patients (5.8%). Staphylococcus epidermidis was isolated in 22 cases (76%). No case of spinal epidural abscess was observed within 6 months after epidural catheterization. The average catheterization time was 5 days (quartile range: 4 to 6 days). Meticulous management ensures a relatively low level of bacterial contamination in epidural catheters applied for postoperative pain treatment greater than 5 days. Contamination rarely leads to spinal epidural infection.
Sundaram, C P; Saltzman, B
1998-10-01
We describe a simple method to assist stone localization during shock wave lithotripsy in the presence of a Double J stent. A 4F whistle tip ureteral catheter is passed alongside a previously inserted 6F Double J stent. The tip of the ureteral stent is positioned in the lower or mid third of the ureter. Contrast material is injected through the ureteral catheter during lithotripsy to assist stone localization. This technique has been successful in localization of poorly opacified renal stones during lithotripsy. Radiolucent and poorly calcified renal stones can be easily localized during shock wave lithotripsy, despite the presence of a Double J stent. No special catheters or stents are required for this technique.
Detection of electrophysiology catheters in noisy fluoroscopy images.
Franken, Erik; Rongen, Peter; van Almsick, Markus; ter Haar Romeny, Bart
2006-01-01
Cardiac catheter ablation is a minimally invasive medical procedure to treat patients with heart rhythm disorders. It is useful to know the positions of the catheters and electrodes during the intervention, e.g. for the automatization of cardiac mapping. Our goal is therefore to develop a robust image analysis method that can detect the catheters in X-ray fluoroscopy images. Our method uses steerable tensor voting in combination with a catheter-specific multi-step extraction algorithm. The evaluation on clinical fluoroscopy images shows that especially the extraction of the catheter tip is successful and that the use of tensor voting accounts for a large increase in performance.
Magnetic catheter manipulation in the interventional MR imaging environment.
Wilson, Mark W; Martin, Alastair B; Lillaney, Prasheel; Losey, Aaron D; Yee, Erin J; Bernhardt, Anthony; Malba, Vincent; Evans, Lee; Sincic, Ryan; Saeed, Maythem; Arenson, Ronald L; Hetts, Steven W
2013-06-01
To evaluate deflection capability of a prototype endovascular catheter, which is remotely magnetically steerable, for use in the interventional magnetic resonance (MR) imaging environment. Copper coils were mounted on the tips of commercially available 2.3-3.0-F microcatheters. The coils were fabricated in a novel manner by plasma vapor deposition of a copper layer followed by laser lithography of the layer into coils. Orthogonal helical (ie, solenoid) and saddle-shaped (ie, Helmholtz) coils were mounted on a single catheter tip. Microcatheters were tested in water bath phantoms in a 1.5-T clinical MR scanner, with variable simultaneous currents applied to the coils. Catheter tip deflection was imaged in the axial plane by using a "real-time" steady-state free precession MR imaging sequence. Degree of deflection and catheter tip orientation were measured for each current application. The catheter tip was clearly visible in the longitudinal and axial planes. Magnetic field artifacts were visible when the orthogonal coils at the catheter tip were energized. Variable amounts of current applied to a single coil demonstrated consistent catheter deflection in all water bath experiments. Changing current polarity reversed the observed direction of deflection, whereas current applied to two different coils resulted in deflection represented by the composite vector of individual coil activations. Microcatheter navigation through the vascular phantom was successful through control of applied current to one or more coils. Controlled catheter deflection is possible with laser lithographed multiaxis coil-tipped catheters in the MR imaging environment. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.
Hetts, S.W.; Saeed, M.; Martin, A.J.; Evans, L.; Bernhardt, A.F.; Malba, V.; Settecase, F.; Do, L.; Yee, E.J.; Losey, A.; Sincic, R.; Roy, S.; Arenson, R.L.; Wilson, M.W.
2013-01-01
BACKGROUND AND PURPOSE: Endovascular navigation under MR imaging guidance can be facilitated by a catheter with steerable microcoils on the tip. Not only do microcoils create visible artifacts allowing catheter tracking, but also they create a small magnetic moment permitting remote-controlled catheter tip deflection. A side product of catheter tip electrical currents, however, is the heat that might damage blood vessels. We sought to determine the upper boundary of electrical currents safely usable at 1.5T in a coil-tipped microcatheter system. MATERIALS AND METHODS: Alumina tubes with solenoid copper coils were attached to neurovascular microcatheters with heat shrink-wrap. Catheters were tested in carotid arteries of 8 pigs. The catheters were advanced under x-ray fluoroscopy and MR imaging. Currents from 0 mA to 700 mA were applied to test heating and potential vascular damage. Postmortem histologic analysis was the primary endpoint. RESULTS: Several heat-mitigation strategies demonstrated negligible vascular damage compared with control arteries. Coil currents ≤300 mA resulted in no damage (0/58 samples) compared with 9 (25%) of 36 samples for > 300-mA activations (P = .0001). Tip coil activation ≤1 minute and a proximal carotid guide catheter saline drip > 2 mL/minute also had a nonsignificantly lower likelihood of vascular damage. For catheter tip coil activations ≤300 mA for ≤1 minute in normal carotid flow, 0 of 43 samples had tissue damage. CONCLUSIONS: Activations of copper coils at the tip of microcatheters at low currents in 1.5T MR scanners can be achieved without significant damage to blood vessel walls in a controlled experimental setting. Further optimization of catheter design and procedure protocols is necessary for safe remote control magnetic catheter guidance. PMID:23846795
21 CFR 870.1370 - Catheter tip occluder.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter tip occluder. 870.1370 Section 870.1370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1370 Catheter tip occluder...
21 CFR 870.1370 - Catheter tip occluder.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter tip occluder. 870.1370 Section 870.1370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1370 Catheter tip occluder...
21 CFR 870.2870 - Catheter tip pressure transducer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter tip pressure transducer. 870.2870 Section 870.2870 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2870 Catheter tip...
Multifunctional catheters combining intracardiac ultrasound imaging and electrophysiology sensing.
Stephens, D N; Cannata, J; Liu, Ruibin; Zhao, Jian Zhong; Shung, K K; Nguyen, Hien; Chia, R; Dentinger, A; Wildes, D; Thomenius, K E; Mahajan, A; Shivkumar, K; Kim, Kang; O'Donnell, M; Nikoozadeh, A; Oralkan, O; Khuri-Yakub, P T; Sahn, D J
2008-07-01
A family of 3 multifunctional intracardiac imaging and electrophysiology (EP) mapping catheters has been in development to help guide diagnostic and therapeutic intracardiac EP procedures. The catheter tip on the first device includes a 7.5 MHz, 64-element, side-looking phased array for high resolution sector scanning. The second device is a forward-looking catheter with a 24-element 14 MHz phased array. Both of these catheters operate on a commercial imaging system with standard software. Multiple EP mapping sensors were mounted as ring electrodes near the arrays for electrocardiographic synchronization of ultrasound images and used for unique integration with EP mapping technologies. To help establish the catheters' ability for integration with EP interventional procedures, tests were performed in vivo in a porcine animal model to demonstrate both useful intracardiac echocardiographic (ICE) visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheters also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. The companion paper of this work discusses the catheter design of the side-looking catheter with special attention to acoustic lens design. The third device in development is a 10 MHz forward-looking ring array that is to be mounted at the distal tip of a 9F catheter to permit use of the available catheter lumen for adjunctive therapy tools.
Discriminating Tissue Stiffness with a Haptic Catheter: Feeling the Inside of the Beating Heart
Kesner, Samuel B.; Howe, Robert D.
2011-01-01
Catheter devices allow physicians to access the inside of the human body easily and painlessly through natural orifices and vessels. Although catheters allow for the delivery of fluids and drugs, the deployment of devices, and the acquisition of the measurements, they do not allow clinicians to assess the physical properties of tissue inside the body due to the tissue motion and transmission limitations of the catheter devices, including compliance, friction, and backlash. The goal of this research is to increase the tactile information available to physicians during catheter procedures by providing haptic feedback during palpation procedures. To accomplish this goal, we have developed the first motion compensated actuated catheter system that enables haptic perception of fast moving tissue structures. The actuated catheter is instrumented with a distal tip force sensor and a force feedback interface that allows users to adjust the position of the catheter while experiencing the forces on the catheter tip. The efficacy of this device and interface is evaluated through a psychophyisical study comparing how accurately users can differentiate various materials attached to a cardiac motion simulator using the haptic device and a conventional manual catheter. The results demonstrate that haptics improves a user's ability to differentiate material properties and decreases the total number of errors by 50% over the manual catheter system. PMID:25285321
21 CFR 870.2870 - Catheter tip pressure transducer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment for... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into...
21 CFR 870.2870 - Catheter tip pressure transducer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment for... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into...
21 CFR 870.2870 - Catheter tip pressure transducer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment for... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into...
21 CFR 870.2870 - Catheter tip pressure transducer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment for... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into...
Mundi, Manpreet S; Edakkanambeth Varayil, Jithinraj; McMahon, Megan T; Okano, Akiko; Vallumsetla, Nishanth; Bonnes, Sara L; Andrews, James C; Hurt, Ryan T
2016-04-01
Parenteral nutrition (PN) is a life-saving therapy for patients with intestinal failure. Safe delivery of hyperosmotic solution requires a central venous catheter (CVC) with tip in the lower superior vena cava (SVC) or at the SVC-right atrium (RA) junction. To reduce cost and delay in use of CVC, new techniques such as intravascular electrocardiogram (ECG) are being used for tip confirmation in place of chest x-ray (CXR). The present study assessed for accuracy of ECG confirmation in home PN (HPN). Records for all patients consulted for HPN from December 17, 2014, to June 16, 2015, were reviewed for patient demographics, diagnosis leading to HPN initiation, and ECG and CXR confirmation. CXRs were subsequently reviewed by a radiologist to reassess location of the CVC tip and identify those that should be adjusted. Seventy-three patients were eligible, and after assessment for research authorization and postplacement CXR, 17 patients (30% male) with an age of 54 ± 14 years were reviewed. In all patients, postplacement intravascular ECG reading stated tip in the SVC. However, based on CXR, the location of the catheter tip was satisfactory (low SVC or SVC-RA junction) in 10 of 17 patients (59%). Due to the high osmolality of PN, CVC tip location is of paramount importance. After radiology review of CXR, we noted that 7 of 17 (41%) peripherally inserted central catheter lines were in an unsatisfactory position despite ECG confirmation. With current data available, intravenous ECG confirmation should not be used as the sole source of tip confirmation in patients receiving HPN. © 2016 American Society for Parenteral and Enteral Nutrition.
SU-E-T-362: Automatic Catheter Reconstruction of Flap Applicators in HDR Surface Brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buzurovic, I; Devlin, P; Hansen, J
2014-06-01
Purpose: Catheter reconstruction is crucial for the accurate delivery of radiation dose in HDR brachytherapy. The process becomes complicated and time-consuming for large superficial clinical targets with a complex topology. A novel method for the automatic catheter reconstruction of flap applicators is proposed in this study. Methods: We have developed a program package capable of image manipulation, using C++class libraries of The-Visualization-Toolkit(VTK) software system. The workflow for automatic catheter reconstruction is: a)an anchor point is placed in 3D or in the axial view of the first slice at the tip of the first, last and middle points for the curvedmore » surface; b)similar points are placed on the last slice of the image set; c)the surface detection algorithm automatically registers the points to the images and applies the surface reconstruction filter; d)then a structured grid surface is generated through the center of the treatment catheters placed at a distance of 5mm from the patient's skin. As a result, a mesh-style plane is generated with the reconstructed catheters placed 10mm apart. To demonstrate automatic catheter reconstruction, we used CT images of patients diagnosed with cutaneous T-cell-lymphoma and imaged with Freiburg-Flap-Applicators (Nucletron™-Elekta, Netherlands). The coordinates for each catheter were generated and compared to the control points selected during the manual reconstruction for 16catheters and 368control point Results: The variation of the catheter tip positions between the automatically and manually reconstructed catheters was 0.17mm(SD=0.23mm). The position difference between the manually selected catheter control points and the corresponding points obtained automatically was 0.17mm in the x-direction (SD=0.23mm), 0.13mm in the y-direction (SD=0.22mm), and 0.14mm in the z-direction (SD=0.24mm). Conclusion: This study shows the feasibility of the automatic catheter reconstruction of flap applicators with a high level of positioning accuracy. Implementation of this technique has potential to decrease the planning time and may improve overall quality in superficial brachytherapy.« less
Modeling and estimation of tip contact force for steerable ablation catheters.
Khoshnam, Mahta; Skanes, Allan C; Patel, Rajni V
2015-05-01
The efficacy of catheter-based cardiac ablation procedures can be significantly improved if real-time information is available concerning contact forces between the catheter tip and cardiac tissue. However, the widely used ablation catheters are not equipped for force sensing. This paper proposes a technique for estimating the contact forces without direct force measurements by studying the changes in the shape of the deflectable distal section of a conventional 7-Fr catheter (henceforth called the "deflectable distal shaft," the "deflectable shaft," or the "shaft" of the catheter) in different loading situations. First, the shaft curvature when the tip is moving in free space is studied and based on that, a kinematic model for the deflectable shaft in free space is proposed. In the next step, the shaft shape is analyzed in the case where the tip is in contact with the environment, and it is shown that the curvature of the deflectable shaft provides useful information about the loading status of the catheter and can be used to define an index for determining the range of contact forces exerted by the ablation tip. Experiments with two different steerable ablation catheters show that the defined index can detect the range of applied contact forces correctly in more than 80% of the cases. Based on the proposed technique, a framework for obtaining contact force information by using the shaft curvature at a limited number of points along the deflectable shaft is constructed. The proposed kinematic model and the force estimation technique can be implemented together to describe the catheter's behavior before contact, detect tip/tissue contact, and determine the range of contact forces. This study proves that the flexibility of the catheter's distal shaft provides a means of estimating the force exerted on tissue by the ablation tip.
Low-angled peripheral intravenous catheter tip placement decreases phlebitis.
Tanabe, Hidenori; Murayama, Ryoko; Yabunaka, Koichi; Oe, Makoto; Takahashi, Toshiaki; Komiyama, Chieko; Sanada, Hiromi
2016-11-02
Peripheral intravenous catheters (PIVCs) are frequently removed due to phlebitis. We hypothesized that catheters made of polyurethane, which is more flexible than Teflon, would decrease phlebitis, and that flexibility could be estimated by measuring the catheter-tip angle. Ultrasonography in two groups of patients with different catheter types was then used to compare catheter-tip angles and phlebitis. Observational studies were carried out at a medical ward in a university hospital. Infusion therapy was administered to one group of patients in 2014 using Teflon catheters (control group, n = 200), and to another group of patients in 2015 using polyurethane catheters (investigational group, n = 207). The symptoms were assessed according to a scale developed by the Infusion Nurses Society. Long-axis ultrasonography images taken immediately before catheter removal were used to measure the angle between the central line of the catheter within 2 mm from the distal point and a tangent to the vessel wall. There were no significant differences between the two groups with respect to sex, age, and medical diagnosis. In the control and investigational groups, the rates of phlebitis were 37% (73/200) and 17% (36/207), respectively (p<0.001). The median angles of the catheter tip were 7.8° and 4.1°, respectively (p<0.001). Phlebitis occurred more frequently when the catheter-tip was placed at angle >5.8°. The frequency of phlebitis was lower in the polyurethane, in which the catheter was placed at lower angle, almost parallel to the vessel. Our results will aid in developing new catheters and in improving PIVC-securement techniques.
Multifunctional Catheters Combining Intracardiac Ultrasound Imaging and Electrophysiology Sensing
Stephens, Douglas N.; Cannata, Jonathan; Liu, Ruibin; Zhao, Jian Zhong; Shung, K. Kirk; Nguyen, Hien; Chia, Raymond; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai E.; Mahajan, Aman; Shivkumar, Kalyanam; Kim, Kang; O’Donnell, Matthew; Nikoozadeh, Amin; Oralkan, Omer; Khuri-Yakub, Pierre T.; Sahn, David J.
2015-01-01
A family of 3 multifunctional intracardiac imaging and electrophysiology (EP) mapping catheters has been in development to help guide diagnostic and therapeutic intracardiac EP procedures. The catheter tip on the first device includes a 7.5 MHz, 64-element, side-looking phased array for high resolution sector scanning. The second device is a forward-looking catheter with a 24-element 14 MHz phased array. Both of these catheters operate on a commercial imaging system with standard software. Multiple EP mapping sensors were mounted as ring electrodes near the arrays for electrocardiographic synchronization of ultrasound images and used for unique integration with EP mapping technologies. To help establish the catheters’ ability for integration with EP interventional procedures, tests were performed in vivo in a porcine animal model to demonstrate both useful intracardiac echocardiographic (ICE) visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheters also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. The companion paper of this work discusses the catheter design of the side-looking catheter with special attention to acoustic lens design. The third device in development is a 10 MHz forward-looking ring array that is to be mounted at the distal tip of a 9F catheter to permit use of the available catheter lumen for adjunctive therapy tools. PMID:18986948
Li, Whenzheng; Li, Fang; Wang, He; Long, Xueying; Ghimire, Obin; Pei, Yigang; Xiao, Xiangcheng; Ning, Jianping
2017-01-01
Abstract Background: Catheter-related thrombotic complications(TCs) can occur during the long term use of a chronic dialysis catheter (CDC), including fibrin sheath (FS), mural thrombosis (MT), venous thrombosis (VT), and intraluminal clots (IC), which has not been reported with MRI. The aim of our study was to evaluate the determination of catheter tip position (TP) and resolution of TCs in patients with transjugular CDC scheduled into the superior vena cava using high resolution magnetic resonance cholangiopancreatography (HR-MRCP) and T2-weighted imaging (HR-T2WI). Methods: The study protocol was approved by the local Research Ethics Committee. Informed consent was obtained from all patients. In total, 41 consecutively enrolled transjugular CDC patients with suspected catheter dysfunction were scanned with HRMRCP and HR-T2WI. The distance from the top to the tip of the catheter and the presence and nature of catheter TCs were assessed by 2 experienced radiologists. Chest x-ray was taken within 1 to 2 days and CDC was withdrawn within 3 to 10 days from those patients with TCs identified by HR-MRI. Results: A total of 38 subjects successfully underwent HR-MRI, including 13 normal and 25 with TCs (fibrin sheath [FS]: n = 21, mural thrombosis [MT]: n = 7, venous thrombosis [VT]: n = 3, intraluminal clots [IC]: n = 4). There was no significant difference between HR-MRCP and chest x-ray in catheter TP determination (P = .124). Normal catheter appeared as “double eyes” on HR-T2WI and “double tracks” on HR-MRCP. TCs appeared as follows: FS displayed as a “thin ring” (<1mm) around the catheter, MT as patchy hyperintensity and VT as a “thick ring” (>5mm) on HR-T2WI. Unilateral IC appeared as a “single eye” on HR-T2WI and a “single track” on HR-MRCP (n = 3). Bilateral IC appeared as neither “eye” nor “track” (n = 1). Catheter withdrawal confirmed FS (n = 16), MT (n = 6), VT (n = 1), and IC (n = 4). Conclusion: HR-MRCP and HR-T2WI are promising methods for visualizing TP and TCs in CDC patients, and are helpful in adjusting the treatment plan and avoiding the risk of pulmonary embolism. PMID:28658104
Percutaneous Endovascular Salvage Techniques for Implanted Venous Access Device Dysfunction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Breault, Stéphane, E-mail: stephane.breault@chuv.ch; Glauser, Frédéric, E-mail: frederic.glauser@chuv.ch; Babaker, Malik, E-mail: malik.babaker@chuv.ch
2015-06-15
PurposeImplanted venous access devices (IVADs) are often used in patients who require long-term intravenous drug administration. The most common causes of device dysfunction include occlusion by fibrin sheath and/or catheter adherence to the vessel wall. We present percutaneous endovascular salvage techniques to restore function in occluded catheters. The aim of this study was to evaluate the feasibility, safety, and efficacy of these techniques.Methods and MaterialsThrough a femoral or brachial venous access, a snare is used to remove fibrin sheath around the IVAD catheter tip. If device dysfunction is caused by catheter adherences to the vessel wall, a new “mechanical adhesiolysis”more » maneuver was performed. IVAD salvage procedures performed between 2005 and 2013 were analyzed. Data included clinical background, catheter tip position, success rate, recurrence, and rate of complication.ResultsEighty-eight salvage procedures were performed in 80 patients, mostly women (52.5 %), with a mean age of 54 years. Only a minority (17.5 %) of evaluated catheters were located at an optimal position (i.e., cavoatrial junction ±1 cm). Mechanical adhesiolysis or other additional maneuvers were used in 21 cases (24 %). Overall technical success rate was 93.2 %. Malposition and/or vessel wall adherences were the main cause of technical failure. No complications were noted.ConclusionThese IVAD salvage techniques are safe and efficient. When a catheter is adherent to the vessel wall, mechanical adhesiolysis maneuvers allow catheter mobilization and a greater success rate with no additional risk. In patients who still require long-term use of their IVAD, these procedures can be performed safely to avoid catheter replacement.« less
Micromachined actuators/sensors for intratubular positioning/steering
Lee, Abraham P.; Krulevitch, Peter A.; Northrup, M. Allen; Trevino, Jimmy C.
1998-01-01
Micromachined thin film cantilever actuators having means for individually controlling the deflection of the cantilevers, valve members, and rudders for steering same through blood vessels, or positioning same within a blood vessel, for example. Such cantilever actuators include tactile sensor arrays mounted on a catheter or guide wire tip for navigation and tissues identification, shape-memory alloy film based catheter/guide wire steering mechanisms, and rudder-based steering devices that allow the selective actuation of rudders that use the flowing blood itself to help direct the catheter direction through the blood vessel. While particularly adapted for medical applications, these cantilever actuators can be used for steering through piping and tubing systems.
Riboli, Danilo Flávio Moraes; Lyra, João César; Silva, Eliane Pessoa; Valadão, Luisa Leite; Bentlin, Maria Regina; Corrente, José Eduardo; Rugolo, Ligia Maria Suppo de Souza; da Cunha, Maria de Lourdes Ribeiro de Souza
2014-05-22
Catheter-related bloodstream infections (CR-BSIs) have become the most common cause of healthcare-associated bloodstream infections in neonatal intensive care units (ICUs). Microbiological evidence implicating catheters as the source of bloodstream infection is necessary to establish the diagnosis of CR-BSIs. Semi-quantitative culture is used to determine the presence of microorganisms on the external catheter surface, whereas quantitative culture also isolates microorganisms present inside the catheter. The main objective of this study was to determine the sensitivity and specificity of these two techniques for the diagnosis of CR-BSIs in newborns from a neonatal ICU. In addition, PFGE was used for similarity analysis of the microorganisms isolated from catheters and blood cultures. Semi-quantitative and quantitative methods were used for the culture of catheter tips obtained from newborns. Strains isolated from catheter tips and blood cultures which exhibited the same antimicrobial susceptibility profile were included in the study as positive cases of CR-BSI. PFGE of the microorganisms isolated from catheters and blood cultures was performed for similarity analysis and detection of clones in the ICU. A total of 584 catheter tips from 399 patients seen between November 2005 and June 2012 were analyzed. Twenty-nine cases of CR-BSI were confirmed. Coagulase-negative staphylococci (CoNS) were the most frequently isolated microorganisms, including S. epidermidis as the most prevalent species (65.5%), followed by S. haemolyticus (10.3%), yeasts (10.3%), K. pneumoniae (6.9%), S. aureus (3.4%), and E. coli (3.4%). The sensitivity of the semi-quantitative and quantitative techniques was 72.7% and 59.3%, respectively, and specificity was 95.7% and 94.4%. The diagnosis of CR-BSIs based on PFGE analysis of similarity between strains isolated from catheter tips and blood cultures showed 82.6% sensitivity and 100% specificity. The semi-quantitative culture method showed higher sensitivity and specificity for the diagnosis of CR-BSIs in newborns when compared to the quantitative technique. In addition, this method is easier to perform and shows better agreement with the gold standard, and should therefore be recommended for routine clinical laboratory use. PFGE may contribute to the control of CR-BSIs by identifying clusters of microorganisms in neonatal ICUs, providing a means of determining potential cross-infection between patients.
Direct cooling of the catheter tip increases safety for CMR-guided electrophysiological procedures
2012-01-01
Background One of the safety concerns when performing electrophysiological (EP) procedures under magnetic resonance (MR) guidance is the risk of passive tissue heating due to the EP catheter being exposed to the radiofrequency (RF) field of the RF transmitting body coil. Ablation procedures that use catheters with irrigated tips are well established therapeutic options for the treatment of cardiac arrhythmias and when used in a modified mode might offer an additional system for suppressing passive catheter heating. Methods A two-step approach was chosen. Firstly, tests on passive catheter heating were performed in a 1.5 T Avanto system (Siemens Healthcare Sector, Erlangen, Germany) using a ASTM Phantom in order to determine a possible maximum temperature rise. Secondly, a phantom was designed for simulation of the interface between blood and the vascular wall. The MR-RF induced temperature rise was simulated by catheter tip heating via a standard ablation generator. Power levels from 1 to 6 W were selected. Ablation duration was 120 s with no tip irrigation during the first 60 s and irrigation at rates from 2 ml/min to 35 ml/min for the remaining 60 s (Biotronik Qiona Pump, Berlin, Germany). The temperature was measured with fluoroscopic sensors (Luxtron, Santa Barbara, CA, USA) at a distance of 0 mm, 2 mm, 4 mm, and 6 mm from the catheter tip. Results A maximum temperature rise of 22.4°C at the catheter tip was documented in the MR scanner. This temperature rise is equivalent to the heating effect of an ablator's power output of 6 W at a contact force of the weight of 90 g (0.883 N). The catheter tip irrigation was able to limit the temperature rise to less than 2°C for the majority of examined power levels, and for all examined power levels the residual temperature rise was less than 8°C. Conclusion Up to a maximum of 22.4°C, the temperature rise at the tissue surface can be entirely suppressed by using the catheter's own irrigation system. The irrigated tip system can be used to increase MR safety of EP catheters by suppressing the effects of unwanted passive catheter heating due to RF exposure from the MR scanner. PMID:22296883
Heart catheter cable and connector
NASA Technical Reports Server (NTRS)
Harrison, D. R.; Cota, F. L.; Sandler, H.
1972-01-01
Ultraminiature catheter cables that are stiff enough for intravenous insertion yet flexible at the tip, sterilizable, and economical are fabricated entirely from commercially available parts. Assembly includes air passageway for reference pressures and coaxial cable for transmission of signals from the tip of catheter.
Kim, Se-Chan; Heinze, Ingo; Schmiedel, Alexandra; Baumgarten, Georg; Knuefermann, Pascal; Hoeft, Andreas; Weber, Stefan
2015-01-01
Visualisation of a central venous catheter (CVC) with ultrasound is restricted to the internal jugular vein (IJV). CVC tip position is confirmed by chest radiography, intracardiac ECG or transoesophageal/transthoracic echocardiography (TEE/TTE). We explored the feasibility, safety and accuracy of a right supraclavicular view for visualisation of the lower superior vena cava (SVC) and the right pulmonary artery (RPA) as an ultrasound landmark for real-time ultrasound-guided CVC tip positioning via the right IJV. Ultrasound was then compared with chest radiography. An observational pilot study. Bonn, University Hospital, Germany. From July to October 2012. Fifty-one patients scheduled for elective surgery. Reasons for exclusion were emergency procedure, thrombosis or small IJV lumen and mechanical obstacle to guidewire advancement. In 48 patients, CVC insertion via the right IJV and progress of the guidewire into the lower SVC were continuously guided by an ultrasound transducer in the right supraclavicular fossa. CVC tip position in lower SVC and tip-to-carina distance were assessed with chest radiography as a reference method and additionally with TEE in cardiothoracic patients. Insertion depth was compared with intracardiac ECG and body-height formula. The guidewire tip was seen in the SVC of all patients. In four patients, the tip was not visible in proximity of the RPA. Chest radiography and TEE confirmed CVC tip position in the lower SVC (zone A). Bland-Altman analysis revealed an average of difference of 1.6 cm for ultrasound versus ECG (95% limit of agreement -2 to 5 cm) and an average of difference of 1 cm for ultrasound versus body-height formula (95% limit of agreement -2 to 4 cm). Ultrasound via a right supraclavicular view is a feasible, well tolerated and accurate approach and should be further explored. Chest radiography confirmed CVC position in the lower SVC.
RF HEATING OF MRI-ASSISTED CATHETER STEERING COILS FOR INTERVENTIONAL MRI
Settecase, Fabio; Hetts, Steven W.; Martin, Alastair J.; Roberts, Timothy P. L.; Bernhardt, Anthony F.; Evans, Lee; Malba, Vincent; Saeed, Maythem; Arenson, Ronald L.; Kucharzyk, Walter; Wilson, Mark W.
2010-01-01
RATIONALE AND OBJECTIVES To assess magnetic resonance imaging (MRI) radiofrequency (RF) related heating of conductive wire coils used in magnetically steerable endovascular catheters. MATERIALS AND METHODS A 3-axis microcoil was fabricated onto a 1.8 Fr catheter tip. In vitro testing was performed in a 1.5 T MRI system using an agarose gel filled vessel phantom, a transmit/receive body RF coil and a steady state free precession (SSFP) pulse sequence, and a fluoroptic thermometry system. Temperature was measured without simulated blood flow at varying distances from magnet isocenter and varying flip angles. Additional experiments were performed with laser-lithographed single-axis microcoil-tipped microcatheters in air and in a saline bath with varied grounding of the microcoil wires. Preliminary in vivo evaluation of RF heating was performed in pigs at 1.5 T with coil-tipped catheters in various positions in the common carotid arteries with SSFP pulse sequence on and off, and under physiologic flow and zero flow conditions. RESULTS In tissue-mimicking agarose gel, RF heating resulted in a maximal temperature increase of 0.35°C after 15 minutes of imaging, 15 cm from magnet isocenter. For a single axis microcoil, maximal temperature increases were 0.73-1.91°C in air and 0.45-0.55°C in saline. In vivo, delayed contrast enhanced MRI revealed no evidence of vascular injury and histopathological sections from the common carotid arteries confirmed the lack of vascular damage. CONCLUSIONS Microcatheter tip microcoils for endovascular catheter steering in MRI experience minimal RF heating under the conditions tested. These data provide the basis for further in vivo testing of this promising technology for endovascular interventional MRI. PMID:21075019
Micromachined actuators/sensors for intratubular positioning/steering
Lee, A.P.; Krulevitch, P.A.; Northrup, M.A.; Trevino, J.C.
1998-06-30
Micromachined thin film cantilever actuators having means for individually controlling the deflection of the cantilevers, valve members, and rudders for steering same through blood vessels, or positioning same within a blood vessel, for example. Such cantilever actuators include tactile sensor arrays mounted on a catheter or guide wire tip for navigation and tissues identification, shape-memory alloy film based catheter/guide wire steering mechanisms, and rudder-based steering devices that allow the selective actuation of rudders that use the flowing blood itself to help direct the catheter direction through the blood vessel. While particularly adapted for medical applications, these cantilever actuators can be used for steering through piping and tubing systems. 14 figs.
Accuracy of chest radiography for positioning of the umbilical venous catheter.
Guimarães, Adriana F M; Souza, Aline A C G de; Bouzada, Maria Cândida F; Meira, Zilda M A
To evaluate the accuracy of the simultaneous analysis of three radiographic anatomical landmarks - diaphragm, cardiac silhouette, and vertebral bodies - in determining the position of the umbilical venous catheter distal end using echocardiography as a reference standard. This was a cross-sectional, observational study, with the prospective inclusion of data from all neonates born in a public reference hospital, between April 2012 and September 2013, submitted to umbilical venous catheter insertion as part of their medical care. The position of the catheter distal end, determined by the simultaneous analysis of three radiographic anatomical landmarks, was compared with the anatomical position obtained by echocardiography; sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated. Of the 162 newborns assessed by echocardiography, only 44 (27.16%) had the catheter in optimal position, in the thoracic portion of the inferior vena cava or at the junction of the inferior vena cava with the right atrium. The catheters were located in the left atrium and interatrial septum in 54 (33.33%) newborns, in the right atrium in 26 (16.05%), intra-hepatic in 37 (22.84%), and intra-aortic in-one newborn (0.62%). The sensitivity, specificity and accuracy of the radiography to detect the catheter in the target area were 56%, 71%, and 67.28%, respectively. Anteroposterior radiography of the chest alone is not able to safely define the umbilical venous catheter position. Echocardiography allows direct visualization of the catheter tip in relation to vascular structures and, whenever possible, should be considered to identify the location of the umbilical venous catheter. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Axe, Robert; Middleditch, Alex; Kelly, Fiona E; Batchelor, Tim J; Cook, Tim M
2015-02-01
Many airway management guidelines include the use of airway exchange catheters (AECs). There are reports, however, of harm from their use, from both malpositioning and in particular from the administration of oxygen via an AEC leading to barotrauma. We used an in vitro pig lung model to investigate the safety of administering oxygen at 4 different flow rates from a high-pressure source via 2 different AECs: a standard catheter and a soft-tipped catheter. Experiments were performed with the catheters positioned either above the carina or below it at the first point of resistance to advancement (hold-up). The experiments were then repeated to produce a series of 32 cases. With an AEC positioned above the carina, we did not observe macroscopic lung damage after the administration of oxygen. The administration of oxygen through an AEC positioned below the carina resulted in macroscopic barotrauma regardless of the rate of oxygen delivery. Increasing speed of oxygen flow led to faster and more extensive damage. Use of an "injector" at 2.5 or 4 bar led to instantaneous macroscopic lung damage and advancement of the AEC through the lung tissue. Our observations were the same when both types of AECs were used. Our results are consistent with reports of harm during the use of AECs and demonstrate the risk of administering oxygen through these devices when they are positioned below the carina. An indicator, ideally made on an AEC at the time of manufacture and designed to lie at the same level as the teeth, may be useful in preventing the insertion of that AEC beyond the level of the carina and improve the safety of using such devices.
Patient-specific catheter shaping for the minimally invasive closure of the left atrial appendage.
Graf, Eva C; Ott, Ilka; Praceus, Julian; Bourier, Felix; Lueth, Tim C
2018-06-01
The minimally invasive closure of the left atrial appendage is a promising alternative to anticoagulation for stroke prevention in patients suffering from atrial fibrillation. One of the challenges of this procedure is the correct positioning and the coaxial alignment of the tip of the catheter sheath to the implant landing zone. In this paper, a novel preoperative planning system is proposed that allows patient-individual shaping of catheters to facilitate the correct positioning of the catheter sheath by offering a patient-specific catheter shape. Based on preoperative three-dimensional image data, anatomical points and the planned implant position are marked interactively and a patient-specific catheter shape is calculated if the standard catheter is not considered as suitable. An approach to calculate a catheter shape with four bends by maximization of the bending radii is presented. Shaping of the catheter is supported by a bending form that is automatically generated in the planning program and can be directly manufactured by using additive manufacturing methods. The feasibility of the planning and shaping of the catheter could be successfully shown using six data sets. The patient-specific catheters were tested in comparison with standard catheters by physicians on heart models. In four of the six tested models, the participating physicians rated the patient-individual catheters better than the standard catheter. The novel approach for preoperatively planned and shaped patient-specific catheters designed for the minimally invasive closure of the left atrial appendage could be successfully implemented and a feasibility test showed promising results in anatomies that are difficult to access with the standard catheter.
Anatomical and functional characteristics of carotid sinus stimulation in humans
NASA Technical Reports Server (NTRS)
Querry, R. G.; Smith, S. A.; Stromstad, M.; Ide, K.; Secher, N. H.; Raven, P. B.
2001-01-01
Transmission characteristics of pneumatic pressure to the carotid sinus were evaluated in 19 subjects at rest and during exercise. Either a percutaneous fluid-filled (n = 12) or balloon-tipped catheter (n = 7) was placed at the carotid bifurcation to record internal transmission of external neck pressure/neck suction (NP/NS). Sustained, 5-s pulses, and rapid ramping pulse protocols (+40 to -80 Torr) were recorded. Transmission of pressure stimuli was less with the fluid-filled catheter compared with that of the balloon-tipped catheter (65% vs. 82% negative pressure, 83% vs. 89% positive pressure; P < 0.05). Anatomical location of the carotid sinus averaged 3.2 cm (left) and 3.6 cm (right) from the gonion of the mandible with a range of 0-7.5 cm. Transmission was not altered by exercise or Valsalva maneuver, but did vary depending on the position of the carotid sinus locus beneath the sealed chamber. These data indicate that transmission of external NP/NS was higher than previously recorded in humans, and anatomical variation of carotid sinus location and equipment design can affect transmission results.
Development of Bend Sensor for Catheter Tip
NASA Astrophysics Data System (ADS)
Nagano, Yoshitaka; Sano, Akihito; Fujimoto, Hideo
Recently, a minimally invasive surgery which makes the best use of the catheter has been becoming more popular. In endovascular coil embolization for a cerebral aneurysm, the observation of the catheter's painting phenomenon is very important to execute the appropriate manipulation of the delivery wire and the catheter. In this study, the internal bend sensor which consists of at least two bending enhanced plastic optical fibers was developed in order to measure the curvature of the catheter tip. Consequently, the painting could be more sensitively detected in the neighborhood of the aneurysm. In this paper, the basic characteristics of the developed sensor system are described and its usefulness is confirmed from the comparison of the insertion force of delivery wire and the curvature of catheter tip in the experiment of coil embolization.
Giannakopoulos, Stilianos; Bantis, Athanasios; Kalaitzis, Christos; Touloupidis, Stavros
2010-10-01
Occasionally during percutaneous surgery, significant contrast extravasation obscures the field, making fluoroscopic access no longer feasible. Herein, we describe a salvage technique. The cystoscopically placed, open-end ureteral catheter is exchanged with an angled-tip angiographic catheter. With the aid of a guidewire and under fluoroscopic guidance, the tip of the catheter is placed in a posterior calix. The "bull's eye" technique is then applied to direct the needle into the tip of the catheter. This technique was used in four cases over a 7-year period. Successful access was accomplished in all cases through a middle or upper calix. The catheter serves as a target for providing access to the renal collecting system and facilitates final tract dilatation.
A pilot study to assess adductor canal catheter tip migration in a cadaver model.
Leng, Jody C; Harrison, T Kyle; Miller, Brett; Howard, Steven K; Conroy, Myles; Udani, Ankeet; Shum, Cynthia; Mariano, Edward R
2015-04-01
An adductor canal catheter may facilitate early ambulation after total knee arthroplasty, but there is concern over preoperative placement since intraoperative migration of catheters may occur from surgical manipulation and result in ineffective analgesia. We hypothesized that catheter type and subcutaneous tunneling may influence tip migration for preoperatively inserted adductor canal catheters. In a male unembalmed human cadaver, 20 catheter insertion trials were divided randomly into one of four groups: flexible epidural catheter either tunneled or not tunneled; or rigid stimulating catheter either tunneled or not tunneled. Intraoperative patient manipulation was simulated by five range-of-motion exercises of the knee. Distance and length measurements were performed by a blinded regional anesthesiologist. Changes in catheter tip to nerve distance (p = 0.225) and length of catheter within the adductor canal (p = 0.467) were not different between the four groups. Two of five non-tunneled stimulating catheters (40 %) were dislodged compared to 0/5 in all other groups (p = 0.187). A cadaver model may be useful for assessing migration of regional anesthesia catheters; catheter type and subcutaneous tunneling may not affect migration of adductor canal catheters based on this preliminary study. However, future studies involving a larger sample size, actual patients, and other catheter types are warranted.
Stephens, Douglas N.; Cannata, Jonathan; Liu, Ruibin; Zhao, Jian Zhong; Shung, K. Kirk; Nguyen, Hien; Chia, Raymond; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai E.; Mahajan, Aman; Shivkumar, Kalyanam; Kim, Kang; O’Donnell, Matthew; Sahn, David
2009-01-01
A multifunctional 9F intracardiac imaging and electrophysiology mapping catheter was developed and tested to help guide diagnostic and therapeutic intracardiac electrophysiology (EP) procedures. The catheter tip includes a 7.25-MHz, 64-element, side-looking phased array for high resolution sector scanning. Multiple electrophysiology mapping sensors were mounted as ring electrodes near the array for electrocardiographic synchronization of ultrasound images. The catheter array elevation beam performance in particular was investigated. An acoustic lens for the distal tip array designed with a round cross section can produce an acceptable elevation beam shape; however, the velocity of sound in the lens material should be approximately 155 m/s slower than in tissue for the best beam shape and wide bandwidth performance. To help establish the catheter’s unique ability for integration with electrophysiology interventional procedures, it was used in vivo in a porcine animal model, and demonstrated both useful intracardiac echocardiographic visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheter also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. PMID:18407850
Using electrical impedance to predict catheter-endocardial contact during RF cardiac ablation.
Cao, Hong; Tungjitkusolmun, Supan; Choy, Young Bin; Tsai, Jang-Zern; Vorperian, Vicken R; Webster, John G
2002-03-01
During radio-frequency (RF) cardiac catheter ablation, there is little information to estimate the contact between the catheter tip electrode and endocardium because only the metal electrode shows up under fluoroscopy. We present a method that utilizes the electrical impedance between the catheter electrode and the dispersive electrode to predict the catheter tip electrode insertion depth into the endocardium. Since the resistivity of blood differs from the resistivity of the endocardium, the impedance increases as the catheter tip lodges deeper in the endocardium. In vitro measurements yielded the impedance-depth relations at 1, 10, 100, and 500 kHz. We predict the depth by spline curve interpolation using the obtained calibration curve. This impedance method gives reasonably accurate predicted depth. We also evaluated alternative methods, such as impedance difference and impedance ratio.
New Coaxial Transseptal Needle for Creation of Atrial Septal Defects in Adult Sheep
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uchida, Barry T.; Pavcnik, Dusan, E-mail: pavcnikd@ohsu.edu; Shimohira, Masashi
Objectives: To introduce a new transseptal (TS) needle assembled in our laboratory-the coaxial TS (CTS) needle-and describe our experience with it in creating experimental atrial septal defects (ASD) in adult sheep.BackgroundWith commercially available TS needles, we were not able to consistently perform TS puncture at the fossa ovalis in adult sheep.Material and MethodsTen adult sheep with a mean weight of 63.5 kg were used. The CTS needle consists of four components: a 9F Teflon catheter, a 14-gauge blunt curved-tip metal cannula, a 4F tapered catheter, and a 20-gauge open needle. A transjugular 5F pigtail catheter was used to display themore » septal anatomy by angiocardiography and was left in place to mark the level of the fossa ovalis. The septum was then probed by a transfemoral 5F curved-tip end-hole catheter. The CTS needle was aligned with the tip of the transjugular catheter, and the TS puncture was performed under fluoroscopic guidance. After documenting a left atrial position, a balloon angioplasty catheter was used for creation of the ASD. Results: A small patent foramen ovale was discovered by septal probing in one sheep. All sheep underwent successful TS punctures without complications. The ASD size ranged from 13 to 15 mm. In eight sheep, the ASD was in fossa ovalis. In the first two sheep where the needle was not well aligned with the marking catheter, the ASD was in the septum secundum. No damage to the atrial or other heart structures was found at necropsy. Conclusion: The CTS needle is a suitable needle for TS puncture and ASD creation in adult sheep. Proper alignment of the CTS needle with a catheter marking the fossa ovalis is essential for successful puncture.« less
A pharmacokinetic-pharmacodynamic model for intrathecal baclofen in patients with severe spasticity.
Heetla, H W; Proost, J H; Molmans, B H; Staal, M J; van Laar, T
2016-01-01
Intrathecal baclofen (ITB) has proven to be an effective and safe treatment for severe spasticity. However, although ITB is used extensively, clinical decisions are based on very scarce pharmacokinetic-pharmacodynamic (PKPD) data. The aim of this study was to measure baclofen CSF concentrations and clinical effects after administration of various ITB boluses in patients with spasticity and to create a PKPD model for ITB. Twelve patients with severe spasticity received four different bolus doses of ITB (0, 25, 50, 75 μg and an optional dose of 100 μg), administered via a catheter with the tip at thoracic level (Th) 10. After each bolus, 10 CSF samples were taken at fixed time intervals, using a catheter with the tip located at Th12. Clinical effect was assessed by measuring spasticity with the Modified Ashworth Scale (MAS). These data were used to develop a PKPD model. All patients achieved an adequate spasmolytic effect with ITB doses varying from 50 to 100 μg. No serious side effects were observed. CSF baclofen concentrations, as well as the clinical effects, correlated significantly with ITB doses. The PK model predicted a steep spinal concentration gradient of ITB along the spinal axis. The clinical effect could be predicted using a delayed-effect model. ITB is an effective and safe therapy with, however, a steep concentration gradient along the spinal axis. This means that the administered baclofen is staying mainly around the catheter tip, which stresses the importance to position the ITB catheter tip closely to the targeted spinal level. © 2015 The British Pharmacological Society.
Medical catheters thermally manipulated by fiber optic bundles
Chastagner, Philippe
1992-01-01
A maneuverable medical catheter comprising a flexible tube having a functional tip. The catheter is connected to a control source. The functional tip of the catheter carries a plurality of temperature activated elements arranged in parallel and disposed about the functional tip and held in spaced relation at each end. These elements expand when they are heated. A plurality of fiber optic bundles, each bundle having a proximal end attached to the control source and a distal end attached to one of the elements carry light into the elements where the light is absorbed as heat. By varying the optic fiber that is carrying the light and the intensity of the light, the bending of the elements can be controlled and thus the catheter steered. In an alternate embodiment, the catheter carries a medical instrument for gathering a sample of tissue. The instrument may also be deployed and operated by thermal expansion and contraction of its moving parts.
Fast vision-based catheter 3D reconstruction
NASA Astrophysics Data System (ADS)
Moradi Dalvand, Mohsen; Nahavandi, Saeid; Howe, Robert D.
2016-07-01
Continuum robots offer better maneuverability and inherent compliance and are well-suited for surgical applications as catheters, where gentle interaction with the environment is desired. However, sensing their shape and tip position is a challenge as traditional sensors can not be employed in the way they are in rigid robotic manipulators. In this paper, a high speed vision-based shape sensing algorithm for real-time 3D reconstruction of continuum robots based on the views of two arbitrary positioned cameras is presented. The algorithm is based on the closed-form analytical solution of the reconstruction of quadratic curves in 3D space from two arbitrary perspective projections. High-speed image processing algorithms are developed for the segmentation and feature extraction from the images. The proposed algorithms are experimentally validated for accuracy by measuring the tip position, length and bending and orientation angles for known circular and elliptical catheter shaped tubes. Sensitivity analysis is also carried out to evaluate the robustness of the algorithm. Experimental results demonstrate good accuracy (maximum errors of ±0.6 mm and ±0.5 deg), performance (200 Hz), and robustness (maximum absolute error of 1.74 mm, 3.64 deg for the added noises) of the proposed high speed algorithms.
SU-E-T-366: Clinical Implementation of MR-Guided Vaginal Cylinder Brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Owrangi, A; Jolly, S; Balter, J
2014-06-01
Purpose: To evaluate the accuracy of MR-based vaginal brachytherapy source localization using an in-house MR-visible marker versus the alignment of an applicator model to MR images. Methods: Three consecutive patients undergoing vaginal HDR brachytherapy with a plastic cylinder were scanned with both CT and MRI (including T1- and T2- weighted images). An MR-visible source localization marker, consisting of a sealed thin catheter filled with either water (for T2 contrast) or Gd-doped water (for T1 contrast), was assembled shortly before scanning. Clinically, the applicator channel was digitized on CT with an x-ray marker. To evaluate the efficacy of MR-based applicator reconstruction,more » each MR image volume was aligned locally to the CT images based on the region containing the cylinder. Applicator digitization was performed on the MR images using (1) the MR visible marker and (2) alignment of an applicator surface model from Varian's Brachytherapy Planning software to the MRI images. Resulting source positions were compared with the original CT digitization. Results: Although the source path was visualized by the MR marker, the applicator tip proved difficult to identify due to challenges in achieving a watertight seal. This resulted in observed displacements of the catheter tip, at times >1cm. Deviations between the central source positions identified via aligning the applicator surface model to MR and using the xray marker on CT ranged from 0.07 – 0.19 cm and 0.07 – 0.20 cm on T1- weighted and T2-weighted images, respectively. Conclusion: Based on the current study, aligning the applicator model to MRI provides a practical, current approach to perform MR-based brachytherapy planning. Further study is needed to produce catheters with reliably and reproducibly identifiable tips. Attempts are being made to improve catheter seals, as well as to increase the viscosity of the contrast material to decrease fluid mobility inside the catheter.« less
Determination of lesion size by ultrasound during radiofrequency catheter ablation.
Awad, S; Eick, O
2003-01-01
The catheter tip temperature that is used to control the radiofrequency generator output poorly correlates to lesion size. We, therefore, evaluated lesions created in vitro using a B-mode ultrasound imaging device as a potential means to assess lesion generation during RF applications non-invasively. Porcine ventricular tissue was immersed in saline solution at 37 degrees C. The catheter was fixed in a holder and positioned in a parallel orientation to the tissue with an array transducer (7.5 MHz) app. 3 cm above the tissue. Lesions were produced either in a temperature controlled mode with a 4-mm tip catheter with different target temperatures (50, 60, 70 and 80 degrees C, 80 W maximum output) or in a power controlled mode (25, 50 and 75 W, 20 ml/min irrigation flow) using an irrigated tip catheter. Different contact forces (0.5 N, 1.0 N) were tested, and RF was delivered for 60 s. A total of 138 lesions was produced. Out of these, 128 could be identified on the ultrasound image. The lesion depth and volume was on average 4.1 +/- 1.6 mm and 52 +/- 53 mm3 as determined by ultrasound and 3.9 +/- 1.7 mm and 52 +/- 55 mm3 as measured thereafter, respectively. A linear correlation between the lesion size determined by ultrasound and that measured thereafter was demonstrated with a correlation coefficient of r = 0.87 for lesion depth and r = 0.93 for lesion volume. We conclude that lesions can be assessed by B-mode ultrasound imaging.
Apparent migration of implantable port devices: normal variations in consideration of BMI.
Wyschkon, Sebastian; Löschmann, Jan-Phillip; Scheurig-Münkler, Christian; Nagel, Sebastian; Hamm, Bernd; Elgeti, Thomas
2016-01-01
To evaluate the extent of normal variation in implantable port devices between supine fluoroscopy and upright chest x-ray in relation to body mass index (BMI) based on three different measurement methods. Retrospectively, 80 patients with implanted central venous access port systems from 2012-01-01 until 2013-12-31 were analyzed. Three parameters (two quantitative and one semi-quantitative) were determined to assess port positions: projection of port capsule to anterior ribs (PCP) and intercostal spaces, ratio of extra- and intravascular catheter portions (EX/IV), normalized distance of catheter tip to carina (nCTCD). Changes were analyzed for males and females and normal-weight and overweight patients using analysis of variance with Bonferroni-corrected pairwise comparison. PCP revealed significantly greater changes in chest x-rays in overweight women than in the other groups (p<0.001, F-test). EX/IV showed a significantly higher increase in overweight women than normal-weight women and men and overweight men (p<0.001). nCTCD showed a significantly greater increase in overweight women than overweight men (p = 0.0130). There were no significant differences between the other groups. Inter- and intra-observer reproducibility was high (Cronbach alpha of 0.923-1.0) and best for EX/IV. Central venous port systems show wide normal variations in the projection of catheter tip and port capsule. In overweight women apparent catheter migration is significantly greater compared with normal-weight women and with men. The measurement of EX/IV and PCP are straightforward methods, quick to perform, and show higher reproducibility than measurement of catheter tip-to-carina distance.
Spanos, Stephanie; Booth, Rebekah; Koenig, Heidi; Sikes, Kendra; Gracely, Edward; Kim, In K
2008-08-01
Peripheral intravenous (PIV) catheter insertion is a frequent, painful procedure that is often performed with little or no anesthesia. Current approaches that minimize pain for PIV catheter insertion have several limitations: significant delay for onset of anesthesia, inadequate anesthesia, infectious disease exposure risk from needlestick injuries, and patients' needle phobia. Comparison of the anesthetic effectiveness of J-Tip needle-free jet injection of 1% buffered lidocaine to the anesthetic effectiveness of topical 4% ELA-Max for PIV catheter insertion. A prospective, block-randomized, controlled trial comparing J-Tip jet injection of 1% buffered lidocaine to a 30-minute application of 4% ELA-Max for topical anesthesia in children 8 to 15 years old presenting to a tertiary care pediatric emergency department for PIV catheter insertion. All subjects recorded self-reported visual analog scale (VAS) scores for pain at time of enrollment and pain felt following PIV catheter insertion. Jet injection subjects also recorded pain of jet injection. Subjects were videotaped during jet injection and PIV catheter insertion. Videotapes were reviewed by a single blinded reviewer for observer-reported VAS pain scores for jet injection and PIV catheter insertion. Of the 70 children enrolled, 35 were randomized to the J-Tip jet injection group and 35 to the ELA-Max group. Patient-recorded enrollment VAS scores for pain were similar between groups (P = 0.74). Patient-recorded VAS scores were significantly different between groups immediately after PIV catheter insertion (17.3 for J-Tip jet injection vs 44.6 for ELA-Max, P < 0.001). Blinded reviewer assessed VAS scores for pain after PIV catheter insertion demonstrated a similar trend, but the comparison was not statistically significant (21.7 for J-Tip jet injection vs 31.9 ELA-Max, P = 0.23). J-Tip jet injection of 1% buffered lidocaine provided greater anesthesia than a 30-minute application of ELA-Max according to patient self-assessment of pain for children aged 8 to 15 years undergoing PIV catheter insertion.
SU-F-T-20: Novel Catheter Lumen Recognition Algorithm for Rapid Digitization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dise, J; McDonald, D; Ashenafi, M
Purpose: Manual catheter recognition remains a time-consuming aspect of high-dose-rate brachytherapy (HDR) treatment planning. In this work, a novel catheter lumen recognition algorithm was created for accurate and rapid digitization. Methods: MatLab v8.5 was used to create the catheter recognition algorithm. Initially, the algorithm searches the patient CT dataset using an intensity based k-means filter designed to locate catheters. Once the catheters have been located, seed points are manually selected to initialize digitization of each catheter. From each seed point, the algorithm searches locally in order to automatically digitize the remaining catheter. This digitization is accomplished by finding pixels withmore » similar image curvature and divergence parameters compared to the seed pixel. Newly digitized pixels are treated as new seed positions, and hessian image analysis is used to direct the algorithm toward neighboring catheter pixels, and to make the algorithm insensitive to adjacent catheters that are unresolvable on CT, air pockets, and high Z artifacts. The algorithm was tested using 11 HDR treatment plans, including the Syed template, tandem and ovoid applicator, and multi-catheter lung brachytherapy. Digitization error was calculated by comparing manually determined catheter positions to those determined by the algorithm. Results: he digitization error was 0.23 mm ± 0.14 mm axially and 0.62 mm ± 0.13 mm longitudinally at the tip. The time of digitization, following initial seed placement was less than 1 second per catheter. The maximum total time required to digitize all tested applicators was 4 minutes (Syed template with 15 needles). Conclusion: This algorithm successfully digitizes HDR catheters for a variety of applicators with or without CT markers. The minimal axial error demonstrates the accuracy of the algorithm, and its insensitivity to image artifacts and challenging catheter positioning. Future work to automatically place initial seed positions would improve the algorithm speed.« less
Dunkerley, David A. P.; Slagowski, Jordan M.; Funk, Tobias; Speidel, Michael A.
2017-01-01
Abstract. Scanning-beam digital x-ray (SBDX) is an inverse geometry x-ray fluoroscopy system capable of tomosynthesis-based 3-D catheter tracking. This work proposes a method of dose-reduced 3-D catheter tracking using dynamic electronic collimation (DEC) of the SBDX scanning x-ray tube. This is achieved through the selective deactivation of focal spot positions not needed for the catheter tracking task. The technique was retrospectively evaluated with SBDX detector data recorded during a phantom study. DEC imaging of a catheter tip at isocenter required 340 active focal spots per frame versus 4473 spots in full field-of-view (FOV) mode. The dose-area product (DAP) and peak skin dose (PSD) for DEC versus full FOV scanning were calculated using an SBDX Monte Carlo simulation code. The average DAP was reduced to 7.8% of the full FOV value, consistent with the relative number of active focal spots (7.6%). For image sequences with a moving catheter, PSD was 33.6% to 34.8% of the full FOV value. The root-mean-squared-deviation between DEC-based 3-D tracking coordinates and full FOV 3-D tracking coordinates was less than 0.1 mm. The 3-D distance between the tracked tip and the sheath centerline averaged 0.75 mm. DEC is a feasible method for dose reduction during SBDX 3-D catheter tracking. PMID:28439521
Guembe, M; Pérez-Granda, M J; Rivera, M L; Martín-Rabadán, P; Bouza, E
2015-06-01
A previous study performed in our institution showed that catheter tip (CT) staining by combining acridine orange and Gram stain (GS) before culture anticipated catheter colonization with exhaustive and careful observation by a highly trained technician. Our objective was to assess the validity values of GS without acridine orange on an external smear of CT for predicting catheter colonization and catheter-related bloodstream infection (C-RBSI). We compared different periods of observation and the results of two technicians with different levels of professional experience. Over a 5-month period, the roll-plate technique was preceded by direct GS of all CTs sent to the microbiology laboratory. The reading was taken at ×100 by two observers with different skill levels. Each observer performed a routine examination (3 min along three longitudinal lines) and an exhaustive examination (5 min along five longitudinal lines). The presence of at least one cell was considered positive. All slides were read before culture results were known. We included a total of 271 CTs from 209 patients. The prevalence of catheter colonization and C-RBSI was 16.2 % and 5.1 %, respectively. Routine and exhaustive examinations revealed only 29.5 % and 40.9 % of colonized catheters, respectively (p < 0.001). In contrast, they revealed high negative predictive values for C-RBSI (96.5 % and 96.3 %, respectively). Our study shows that the yield of GS performed directly on CTs is greater when staining is performed exhaustively. However, the decision to implement this approach in daily routine will depend on the prevalence rate of catheter colonization at each institution.
Method and apparatus for guiding ablative therapy of abnormal biological electrical excitation
NASA Technical Reports Server (NTRS)
Armoundas, Antonis A. (Inventor); Feldman, Andrew B. (Inventor); Sherman, Derin A. (Inventor); Cohen, Richard J. (Inventor)
2001-01-01
This invention involves method and apparatus for guiding ablative therapy of abnormal biological electrical excitation. In particular, it is designed for treatment of cardiac arrhythmias. In the method of this invention electrical signals are acquired from passive electrodes, and an inverse dipole method is used to identify the site of origin of an arrhytmia. The location of the tip of the ablation catheter is similarly localized from signals acquired from the passive electrodes while electrical energy is delivered to the tip of the catheter. The catheter tip is then guided to the site of origin of the arrhythmia, and ablative radio frequency energy is delivered to its tip to ablate the site.
RF Heating of MRI-Assisted Catheter Steering Coils for Interventional MRI.
Settecase, Fabio; Hetts, Steven W; Martin, Alastair J; Roberts, Timothy P L; Bernhardt, Anthony F; Evans, Lee; Malba, Vincent; Saeed, Maythem; Arenson, Ronald L; Kucharzyk, Walter; Wilson, Mark W
2011-03-01
The aim of this study was too assess magnetic resonance imaging (MRI) radiofrequency (RF)-related heating of conductive wire coils used in magnetically steerable endovascular catheters. A three-axis microcoil was fabricated onto a 1.8Fr catheter tip. In vitro testing was performed on a 1.5-T MRI system using an agarose gel-filled vessel phantom, a transmit-receive body RF coil, a steady-state free precession pulse sequence, and a fluoroptic thermometry system. Temperature was measured without simulated blood flow at varying distances from the magnet isocenter and at varying flip angles. Additional experiments were performed with laser-lithographed single-axis microcoil-tipped microcatheters in air and in a saline bath with varied grounding of the microcoil wires. Preliminary in vivo evaluation of RF heating was performed in pigs at 1.5 T with coil-tipped catheters in various positions in the common carotid arteries with steady-state free precession pulse sequence on and off and under physiologic-flow and zero-flow conditions. In tissue-mimicking agarose gel, RF heating resulted in a maximal temperature increase of 0.35°C after 15 minutes of imaging, 15 cm from the magnet isocenter. For a single-axis microcoil, maximal temperature increases were 0.73°C to 1.91°C in air and 0.45°C to 0.55°C in saline. In vivo, delayed contrast-enhanced MRI revealed no evidence of vascular injury, and histopathologic sections from the common carotid arteries confirmed the lack of vascular damage. Microcatheter tip microcoils for endovascular catheter steering in MRI experience minimal RF heating under the conditions tested. These data provide the basis for further in vivo testing of this promising technology for endovascular interventional MRI. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.
Real-Time MRI-Guided Cardiac Cryo-Ablation: A Feasibility Study.
Kholmovski, Eugene G; Coulombe, Nicolas; Silvernagel, Joshua; Angel, Nathan; Parker, Dennis; Macleod, Rob; Marrouche, Nassir; Ranjan, Ravi
2016-05-01
MRI-based ablation provides an attractive capability of seeing ablation-related tissue changes in real time. Here we describe a real-time MRI-based cardiac cryo-ablation system. Studies were performed in canine model (n = 4) using MR-compatible cryo-ablation devices built for animal use: focal cryo-catheter with 8 mm tip and 28 mm diameter cryo-balloon. The main steps of MRI-guided cardiac cryo-ablation procedure (real-time navigation, confirmation of tip-tissue contact, confirmation of vessel occlusion, real-time monitoring of a freeze zone formation, and intra-procedural assessment of lesions) were validated in a 3 Tesla clinical MRI scanner. The MRI compatible cryo-devices were advanced to the right atrium (RA) and right ventricle (RV) and their position was confirmed by real-time MRI. Specifically, contact between catheter tip and myocardium and occlusion of superior vena cava (SVC) by the balloon was visually validated. Focal cryo-lesions were created in the RV septum. Circumferential ablation of SVC-RA junction with no gaps was achieved using the cryo-balloon. Real-time visualization of freeze zone formation was achieved in all studies when lesions were successfully created. The ablations and presence of collateral damage were confirmed by T1-weighted and late gadolinium enhancement MRI and gross pathological examination. This study confirms the feasibility of a MRI-based cryo-ablation system in performing cardiac ablation procedures. The system allows real-time catheter navigation, confirmation of catheter tip-tissue contact, validation of vessel occlusion by cryo-balloon, real-time monitoring of a freeze zone formation, and intra-procedural assessment of ablations including collateral damage. © 2016 Wiley Periodicals, Inc.
Lee, A.P.; Krulevitch, P.A.; Northrup, M.A.; Trevino, J.C.
1998-10-13
Micromachined thin film cantilever actuators having means for individually controlling the deflection of the cantilevers, valve members, and rudders for steering same through blood vessels, or positioning same within a blood vessel, for example. Such cantilever actuators include tactile sensor arrays mounted on a catheter or guide wire tip for navigation and tissues identification, shape-memory alloy film based catheter/guide wire steering mechanisms, and rudder-based steering devices that allow the selective actuation of rudders that use the flowing blood itself to help direct the catheter direction through the blood vessel. While particularly adapted for medical applications, these cantilever actuators can be used for steering through piping and tubing systems. 14 figs.
Lee, Abraham P.; Krulevitch, Peter A.; Northrup, M. Allen; Trevino, Jimmy C.
1998-01-01
Micromachined thin film cantilever actuators having means for individually controlling the deflection of the cantilevers, valve members, and rudders for steering same through blood vessels, or positioning same within a blood vessel, for example. Such cantilever actuators include tactile sensor arrays mounted on a catheter or guide wire tip for navigation and tissues identification, shape-memory alloy film based catheter/guide wire steering mechanisms, and rudder-based steering devices that allow the selective actuation of rudders that use the flowing blood itself to help direct the catheter direction through the blood vessel. While particularly adapted for medical applications, these cantilever actuators can be used for steering through piping and tubing systems.
Evans, O; Gowardman, J; Rabbolini, D; McGrail, M; Rickard, C M
2016-03-01
One of the most common and potentially fatal complications in critically ill burns patients is catheter related bloodstream infection (CR-BSI). Lack of in situ diagnostic techniques requires device removal if CR-BSI is suspected with 75-85% of catheters withdrawn unnecessarily. To assess the sensitivity, specificity and accuracy of two in situ diagnostic methods for CR-BSI in an adult ICU burns population: Differential Time to Positivity (DTP) and Semi-Quantitative Superficial Cultures (SQSC). Both arterial (AC) and central venous (CVC) catheters were studied. On clinicians' suspicion of CR-BSI, the CVC and AC were removed. Superficial semi-quantitative cultures were taken by removing the dressings and swabbing within a 3cm radius of the CVC and AC insertion sites, as well as inside each hub of the CVC and AC. Peripheral blood was taken for qualitative culture and the catheter tip sent for semi-quantitative culture. DTP was considered positive if culture of lumen blood became positive at least 120min before peripheral blood with an identical pathogen. Superficial and tip cultures were identified as positive if ≥15 CFUs were grown. CR-BSI was confirmed when both catheter tip culture and peripheral blood culture were positive with the same micro-organism. Sixteen patients (88% male) with an APACHE II score of 22.0 (7.3) were enrolled. The mean age was 45.7 (16.9) years with mean total burn surface area 32.9 (19.4)%. Fifty percent had airway burns. ICU stay was 19.9 (11.1) days. All 16 survived ICU discharge with a hospital survival of 93%. There were 20 episodes of CR-BSI in these 16 patients. For these 20 episodes the exposure time (line days) was 113.15. The CR-BSI rate was 15.6 per 1000 catheter days (95% CI 1.9-56.4). For diagnosis of CR-BSI in either AC and CVC, SQSC had a sensitivity of 50% [95% CI 3-97], specificity 83.3% [95% CI 67-93], PPV 14.3 [95% CI 1-58], NPV 96.8 [95% CI 81-100], accuracy of 81.6% [95%CI 65-92] and diagnostic odds ratio 5.0 [95% CI 0.3-91.5]. To diagnose tip colonisation (>15CFU), sensitivity of SQSC was 75% [95% CI 22-99], specificity 88.2% [95%CI 72-96], PPV 42.7 [95% CI 12-80], NPV96.8% [95% CI 81-100], accuracy 86.8% [95% CI 71-95] and diagnostic odds ratio 22.5 [95% CI 1.9-271.9]. For combined DTP blood cultures, sensitivity for CR-BSI was 50% [95% CI 3-97], with specificity 97% [95% CI 82-100], PPV 50% [5% CI 3-97%], NPV 97% [95% CI 82-100], accuracy 94.3% 95% CI 79-99] and diagnostic odds ratio 32 [95% CI 1.1-970.8]. Both DTP and SQSC displayed high specificity, NPV and accuracy in a population of adult burns patients. These features may make these tests useful for ruling out CR-BSI in this patient group. This study was limited by a low number of events and further research is required. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
Medical catheters thermally manipulated by fiber optic bundles
Chastagner, P.
1992-10-06
A maneuverable medical catheter comprising a flexible tube having a functional tip is described. The catheter is connected to a control source. The functional tip of the catheter carries a plurality of temperature activated elements arranged in parallel and disposed about the functional tip and held in spaced relation at each end. These elements expand when they are heated. A plurality of fiber optic bundles, each bundle having a proximal end attached to the control source and a distal end attached to one of the elements carry light into the elements where the light is absorbed as heat. By varying the optic fiber that is carrying the light and the intensity of the light, the bending of the elements can be controlled and thus the catheter steered. In an alternate embodiment, the catheter carries a medical instrument for gathering a sample of tissue. The instrument may also be deployed and operated by thermal expansion and contraction of its moving parts. 10 figs.
Yalagudri, Sachin; Raju, Narayana; Das, Bharati; Daware, Ashwin; Maiya, Shreesha; Jothiraj, Kannan; Ravikishore, A G
2015-01-01
This study was conducted to assess the acute safety and short term efficacy of renal sympathetic denervation (RSDN) using solid tip radiofrequency ablation (RFA) catheter and saline irrigation through the renal guiding catheter to achieve effective denervation. RSDN using a specialized solid-tip RFA catheter has recently been demonstrated to safely reduce systemic blood pressure in patients with refractory hypertension, the limitation being inadequate power delivery in renal arteries. So, we used solid-tip RFA catheter along with saline irrigation for RSDN. Nine patients with resistant hypertension underwent CT and conventional renal angiography, followed by bilateral or unilateral RSDN using 5F RFA catheter with saline irrigation through renal guiding catheter. Repeat renal angiography was performed at the end of the procedure. In all patients, pre- and post-procedure serum creatinine was measured. Over 1-month period: 1) the systolic/diastolic blood pressure decreased by -57 ± 20/-25 ± 7.5 mm Hg; 2) all patients experienced a decrease in systolic blood pressure of at least -36 mm Hg (range 36-98 mm Hg); 3) there was no evidence of renal artery injury immediate post-procedure. There was no significant change in serum creatinine level. This data shows the acute procedural safety and short term efficacy of RSDN using modified externally irrigated solid tip RFA catheter. Copyright © 2015 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
Schwein, Adeline; Kramer, Ben; Chinnadurai, Ponraj; Walker, Sean; O'Malley, Marcia; Lumsden, Alan; Bismuth, Jean
2017-02-01
One limitation of the use of robotic catheters is the lack of real-time three-dimensional (3D) localization and position updating: they are still navigated based on two-dimensional (2D) X-ray fluoroscopic projection images. Our goal was to evaluate whether incorporating an electromagnetic (EM) sensor on a robotic catheter tip could improve endovascular navigation. Six users were tasked to navigate using a robotic catheter with incorporated EM sensors in an aortic aneurysm phantom. All users cannulated two anatomic targets (left renal artery and posterior "gate") using four visualization modes: (1) standard fluoroscopy mode (control), (2) 2D fluoroscopy mode showing real-time virtual catheter orientation from EM tracking, (3) 3D model of the phantom with anteroposterior and endoluminal view, and (4) 3D model with anteroposterior and lateral view. Standard X-ray fluoroscopy was always available. Cannulation and fluoroscopy times were noted for every mode. 3D positions of the EM tip sensor were recorded at 4 Hz to establish kinematic metrics. The EM sensor-incorporated catheter navigated as expected according to all users. The success rate for cannulation was 100%. For the posterior gate target, mean cannulation times in minutes:seconds were 8:12, 4:19, 4:29, and 3:09, respectively, for modes 1, 2, 3 and 4 (P = .013), and mean fluoroscopy times were 274, 20, 29, and 2 seconds, respectively (P = .001). 3D path lengths, spectral arc length, root mean dimensionless jerk, and number of submovements were significantly improved when EM tracking was used (P < .05), showing higher quality of catheter movement with EM navigation. The EM tracked robotic catheter allowed better real-time 3D orientation, facilitating navigation, with a reduction in cannulation and fluoroscopy times and improvement of motion consistency and efficiency. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Beigi, Parmida; Rohling, Robert
2014-03-01
Despite the wide range and long history of ultrasound guided needle insertions, an unresolved issue in many cases is clear needle visibility. A well-known ad hoc technique to detect the needle is to move the stylet and look for changes in the needle appearance. We present a new method to automatically locate a moving stylet/catheter within a stationary cannula using motion detection. We then use this information to detect the needle trajectory and the tip. The differences between the current frame and the previous frame are detected and localized, to minimize the influence of tissue global motions. A polynomial fit based on the detected needle axis determines the estimated stylet shaft trajectory, and the extent of the differences along the needle axis represents the tip. Over a few periodic movements of the stylet including its full insertion into the cannula to the tip, a combination of polynomial fits determines the needle trajectory and the last detected point represents the needle tip. Experiments are conducted in water bath and bovine muscle tissue for several stylet/catheter materials. Results show that a plastic stylet has the best needle shaft and tip localization accuracy in the water bath with RMSE = 0:16 mm and RMSE = 0:51 mm, respectively. In the bovine tissue, the needle tip was best localized with the plastic catheter with RMSE = 0:33 mm. The stylet tip localization was most accurate with the steel stylet, with RMSE = 2:81 mm and the shaft was best localized with the plastic catheter, with RMSE = 0:32 mm.
Drain Tube-Induced Jejunal Penetration Masquerading as Bile Leak following Whipple's Operation.
Bae, Sang Ho; Lee, Tae Hoon; Lee, Sae Hwan; Lee, Suck-Ho; Park, Sang-Heum; Kim, Sun-Joo; Kim, Chang Ho
2011-05-01
A 70-year-old man had undergone pancreaticoduodenectomy due to a distal common bile duct malignancy. After the operation, serous fluid discharge decreased from two drain tubes in the retroperitoneum. Over four weeks, the appearance of the serous fluid changed to a greenish bile color and the patient persistently drained over 300 ml/day. Viewed as bile leak at the choledochojejunostomy, treatment called for endoscopic diagnosis and therapy. Cap-fitted forward-viewing endoscopy demonstrated that the distal tip of a pancreatic drain catheter inserted at the pancreaticojejunostomy site had penetrated the opposite jejunum wall. One of the drain tubes primarily placed in the retroperitoneum had also penetrated the jejunum wall, with the distal tip positioned near the choledochojejunostomy site. No leak of contrast appeared beyond the jejunum or anastomosis site. Following repositioning of a penetrating catheter of the pancreaticojejunostomy, four days later, the patient underwent removal of two drain tubes without additional complications. In conclusion, the distal tip of the catheter, placed to drain pancreatic juice, penetrated the jejunum wall and may have caused localized perijejunal inflammation. The other drain tube, placed in the retroperitoneal space, might then have penetrated the inflamed wall of the jejunum, allowing persistent bile drainage via the drain tube. The results masqueraded as bile leakage following pancreaticoduodenectomy.
Jia, Zhen Yu; Lee, Sang Hun; Kim, Young Eun; Choi, Joon Ho; Hwang, Sun Moon; Lee, Ga Young; Youn, Jin Ho
2017-01-01
Purpose To determine the minimum required guiding catheter length for embolization of various intracranial aneurysms in anterior circulation and to analyze the effect of various patient factors on the required catheter length and potential interaction with its stability. Materials and Methods From December 2016 to March 2017, 90 patients with 93 anterior circulation aneurysms were enrolled. Three types of guiding catheters (Envoy, Envoy DA, and Envoy DA XB; Codman Neurovascular, Raynham, MA, USA) were used. We measured the in-the-body length of the catheter and checked the catheter tip location in the carotid artery. We analyzed factors affecting the in-the-body length and stability of the guiding catheter system. Results The average (±standard deviation) in-the-body length of the catheter was 84.2±5.9 cm. The length was significantly longer in men (89.1±5.6 vs. 82.1±4.6 cm, P<0.001), patients older than 65 years (87.7±7.8 vs. 82.7±4.2 cm, P<0.001), patients with a more tortuous arch (arch type 2 and 3) (87.5±7.4 vs. 82.7±4.4 cm, P<0.001), and patients with a distal aneurysm location (distal group) (86.2±5.0 vs. 82.7±6.1 cm, P=0.004). A shift in the tip location was noted in 19 patients (20.4%); there was no significant different among the 3 catheters (P=0.942). Conclusion The minimum required length of a guiding catheter was 84 cm on average for elective anterior-circulation aneurysm embolization. The length increased in men older than 65 years with a more tortuous arch. We could reach a higher position with distal access catheters with little difference in the stability once we reached the target location. PMID:28955511
Assessment of navigation cues with proximal force sensing during endovascular catheterization.
Rafii-Taril, Hedyeh; Payne, Christopher J; Riga, Celia; Bicknell, Colin; Lee, Su-Lin; Yang, Guang-Zhong
2012-01-01
Despite increased use of robotic catheter navigation systems for endovascular intervention procedures, current master-slave platforms have not yet taken into account dexterous manipulation skill used in traditional catheterization procedures. Information on tool forces applied by operators is often limited. A novel force/torque sensor is developed in this paper to obtain behavioural data across different experience levels and identify underlying factors that affect overall operator performance. The miniature device can be attached to any part of the proximal end of the catheter, together with a position sensor attached to the catheter tip, for relating tool forces to catheter dynamics and overall performance. The results show clear differences in manipulation skills between experience groups, thus providing insights into different patterns and range of forces applied during routine endovascular procedures. They also provide important design specifications for ergonomically optimized catheter manipulation platforms with added haptic feedback while maintaining natural skills of the operators.
Method and apparatus for the guided ablative therapy of fast ventricular arrhythmia
NASA Technical Reports Server (NTRS)
Cohen, Richard J. (Inventor); Barley, Maya (Inventor)
2010-01-01
Method and apparatus for guiding ablative therapy of abnormal biological electrical excitation. The excitation from the previous excitatory wave is significant at the beginning of the next excitation. In particular, it is designed for treatment of fast cardiac arrhythmias. Electrical signals are acquired from recording electrodes, and an inverse dipole method is used to identify the site of origin of an arrhythmia. The location of the tip of an ablation catheter is similarly localized from signals acquired from the recording electrodes while electrical pacing energy is delivered to the tip of the catheter close to or in contact with the cardiac tissue. The catheter tip is then guided to the site of origin of the arrhythmia, and ablative radio frequency energy is delivered to its tip to ablate the site.
Right ventriculography as a valid method for the diagnosis of tricuspid insufficiency.
Ubago, J L; Figueroa, A; Colman, T; Ochoteco, A; Rodríguez, M; Durán, C M
1981-01-01
The value of right ventriculography in the diagnosis of tricuspid insufficiency (TI) is often questioned because of 1) the high incidence of premature ventricular contractions (PVCs) during injections and 2) interference of the catheter in the valve closure mechanism. In 168 patients a commercially available, not preshaped, balloon-tipped catheter was used for right ventriculography. To avoid the induction of PVCs, the catheter tip was placed in the middle third of the diafragmatic wall of the right ventricle, and the balloon was inflated, becoming trapped by the trabeculae. In this position the catheter's side holes should be located in the inflow chamber. To ensure this correct position, and therefore lack of ectopic beats during angiography, a saline test injection was performed previously in every case. With this technique the incidence of PVCs during ventriculography was only 7.7%. In all but one case, such beats were isolated. The 168 patients were divided into three groups according to their likelihood of experiencing tricuspid interference by the catheter: group 1 included 41 patients with a normal heart or with coronary artery disease. No one from this group had TI. Of group II, 28 patients with right ventricular pressure or volume overload or cardiomyopathy, only 2 had TI, both with a previous clinical diagnosis of regurgitation. Group III contained 99 patients with rheumatic heart disease. Thirty-five of them showed angiographic TI, and 24 of these had this diagnosis confirmed either clinically or at surgery. It is felt that this technique of right ventriculography, with its low incidence of PVCs and slight interference with tricuspid closure, is a valid method for the objective study of the tricuspid valve.
Dettenkofer, M; Wilson, C; Gratwohl, A; Schmoor, C; Bertz, H; Frei, R; Heim, D; Luft, D; Schulz, S; Widmer, A F
2010-06-01
To compare the efficacy of two commercially available, alcohol-based antiseptic solutions for preparation and care of central venous catheter (CVC) insertion sites, with and without octenidine dihydrochloride, a double-blind, randomized, controlled trial was undertaken in the haematology units and in one surgical unit of two university hospitals. Adult patients with a non-tunnelled CVC were randomly assigned to two different skin disinfection regimens at the insertion site: 0.1% octenidine with 30% 1-propanol and 45% 2-propanol, and as control 74% ethanol with 10% 2-propanol. Endpoints were (i) skin colonization at the insertion site; (ii) positive culture from the catheter tip (> or = 15 CFU); and (iii) occurrence of CVC-associated bloodstream infection (defined according to criteria set by the CDC). Four hundred patients with inserted CVC were enrolled from May 2002 through April 2005. Both groups were similar in respect of patient characteristics and co-morbidities. Skin colonization at the CVC insertion site during the first 10 days was significantly reduced by octenidine treatment (relative difference octenidine vs. control: 0.21; 95%CI: 0.11-0.39, p <0.0001). Positive culture of the catheter tip was significantly less frequent in the octenidine group (7.9%) than in the control group (17.8%): OR = 0.39 (95%CI: 0.20-0.80, p 0.009). Patients treated with octenidine had a non-significant reduction in catheter-associated bloodstream infections (4.1% vs. 8.3%; OR = 0.44; 95%CI: 0.18-1.08, p 0.081). Side effects were similar in both groups. This randomized controlled trial supports the results of two observational studies demonstrating octenidine in alcoholic solution to be a better option than alcohol alone for the prevention of CVC-associated infections.
Large eccentric laser angioplasty catheter
NASA Astrophysics Data System (ADS)
Taylor, Kevin D.; Reiser, Christopher
1997-05-01
In response to recent demand for increased debulking of large diameter coronary vascular segments, a large eccentric catheter for excimer laser coronary angioplasty has been developed. The outer tip diameter is 2.0 mm and incorporates approximately 300 fibers of 50 micron diameter in a monorail- type percutaneous catheter. The basic function of the device is to ablate a coronary atherosclerotic lesion with 308 nm excimer laser pulses, while passing the tip of the catheter through the lesion. By employing multiple passes through the lesion, rotating the catheter 90 degrees after each pass, we expect to create luminal diameters close to 3 mm with this device. Design characteristics, in-vitro testing, and initial clinical experience is presented.
Drobinski, G; Thomas, D; Funck, F; Metzger, J P; Canny, M; Grosgogeat, Y
1986-08-01
Certain surgical techniques may make it difficult to catheterize the coronary ostia and perform percutaneous coronary angioplasty. We report the case of a 48 year old patient who developed unstable angina four years after a Bentall's procedure with reimplantation of the coronary arteries on a Dacron coronary prosthesis. The anginal pain was related to very severe stenosis of the proximal segment of the left anterior descending artery. The difficulties encountered during the dilatation procedure were due to: (a) the ectopic position of the ostium of the prosthesis on the anterior aortic wall; (b) the forces exerted on the aortic prosthesis wall and on the valvular prosthesis during positioning of the guiding catheter which were poorly tolerated and induced a vagal reaction; (c) the direction taken by the distal tip of the guiding catheter, perpendicular to the wall of the aortic prosthesis; (d) the sinuosity of the arterial trajectory: the left coronary segment of the coronary prosthesis was directed towards the left circumflex artery rather than towards the left anterior descending artery. Coronary angioplasty succeeded after relatively complex technical procedures: special guiding catheter, unusual intra-aortic manoeuvres for positioning the guiding catheter, dilatation catheter change on a 3-metre long guide wire in order to cross the stenotic segment; this was performed with a super low-profiled dilatation catheter. There were no complications and anginal pain disappeared.
Pérez-Granda, María Jesús; Guembe, María; Cruces, Raquel; Barrio, José María; Bouza, Emilio
2016-02-02
Culture of catheter hubs and skin surrounding the catheter entry site has a negative predictive value for catheter tip colonization. However, manipulation of the hub for culture requires the hubs to be swabbed, introducing potential dislodging of biofilm and subsequent migration of microorganisms. Hubs are usually closed with needleless connectors (NCs), which are replaced regularly. Our objective was to evaluate whether culture of flushed withdrawn NCs is an alternative to hub culture when investigating central venous catheter colonization. The study population comprised 49 intensive care unit patients whose central venous catheters had been in place for at least 7 days. Cultures of NCs and skin were obtained weekly. We included 82 catheters with more than 7 days' indwelling time. The catheter tip colonization rate was 18.3% (15/82). Analysis of skin and NC cultures revealed a 92.5% negative predictive value for catheter colonization. Three episodes of catheter-related bloodstream infection (C-RBSI) occurred in patients with colonized catheters. Surveillance of NC and skin cultures could help to identify patients at risk for C-RBSI.
Sharifi, M; Lauer, J; Pompili, V J; Dillon, J C
1999-11-01
In this report, we describe an alternative method to the conventional arteriographic techniques of the left internal mammary artery (LIMA) graft using a balloon-tipped floatation catheter placed within the left subclavian artery. The floatation catheter will serve as both an occluder of the subclavian artery as well as a port for contrast injection. It may be effectively employed in the rare instances where direct cannulation of the LIMA graft is not possible.
Weiss, Steffen; Wirtz, Daniel; David, Bernd; Krueger, Sascha; Lips, Oliver; Caulfield, Dennis; Pedersen, Steen Fjord; Bostock, Julian; Razavi, Reza; Schaeffter, Tobias
2013-01-01
An MR-electrophysiology (EP) catheter is presented that provides full diagnostic EP functionality and a high level of radiofrequency safety achieved by custom-designed transmission lines. Highly resistive wires transmit intracardiac electrograms and currents for intracardiac pacing. A transformer cable transmits the localization signal of a tip coil. Specific absorption rate simulations and temperature measurements at 1.5 T demonstrate that a wire resistance > 3 kΩ/m limits dielectric heating to a physiologically irrelevant level. Additional wires do not increase tip specific absorption rate significantly, which is important because some clinical catheters require up to 20 electrodes. It is further demonstrated that radiofrequency-induced and pacing-induced resistive heating of the wires is negligible under clinical conditions. The MR-EP catheters provided uncompromised recording of electrograms and cardiac pacing in combination with a standard EP recorder in MR-guided in vivo EP studies, and the tip coil enabled fast and robust catheter localization. In vivo temperature measurements during such a study did not detect any device-related heating, which confirms the high level of safety of the catheter, whereas unacceptable heating was found with a standard EP catheter. The presented concept for the first time enables catheters with full diagnostic EP functionality and active tracking and at the same time a sufficient level of radiofrequency safety for MRI without specific absorption rate-related limitations. PMID:21337409
Weiss, Steffen; Wirtz, Daniel; David, Bernd; Krueger, Sascha; Lips, Oliver; Caulfield, Dennis; Pedersen, Steen Fjord; Bostock, Julian; Razavi, Reza; Schaeffter, Tobias
2011-03-01
An MR-electrophysiology (EP) catheter is presented that provides full diagnostic EP functionality and a high level of radiofrequency safety achieved by custom-designed transmission lines. Highly resistive wires transmit intracardiac electrograms and currents for intracardiac pacing. A transformer cable transmits the localization signal of a tip coil. Specific absorption rate simulations and temperature measurements at 1.5 T demonstrate that a wire resistance > 3 kΩ/m limits dielectric heating to a physiologically irrelevant level. Additional wires do not increase tip specific absorption rate significantly, which is important because some clinical catheters require up to 20 electrodes. It is further demonstrated that radiofrequency-induced and pacing-induced resistive heating of the wires is negligible under clinical conditions. The MR-EP catheters provided uncompromised recording of electrograms and cardiac pacing in combination with a standard EP recorder in MR-guided in vivo EP studies, and the tip coil enabled fast and robust catheter localization. In vivo temperature measurements during such a study did not detect any device-related heating, which confirms the high level of safety of the catheter, whereas unacceptable heating was found with a standard EP catheter. The presented concept for the first time enables catheters with full diagnostic EP functionality and active tracking and at the same time a sufficient level of radiofrequency safety for MRI without specific absorption rate-related limitations. Copyright © 2010 Wiley-Liss, Inc.
Takahashi, Mei; Ito, Arisa; Kajihara, Takuro; Matsuo, Hiroki; Arai, Tsunenori
2010-01-01
The purpose of this study is to investigate transient process of the charring at the laser catheter-tip in blood during therapeutic laser irradiation by the back scattering light measurement to detect precursor state of the charring. We took account of using photodynamic therapy for arrhythmia in blood through the laser catheter. We observed the influence of the red laser irradiation (λ=663 nm) upon the shape of red blood cells (RBCs). The RBCs aggregation, round formation, and hemolysis were took place sequentially before charring. With a model blood sandwiched between glass plates simulated as a catheter-tip boundary, we measured diffuse-reflected-light power and transmitted-light power simultaneously and continuously by a microscopic optics during the laser irradiation. We found that measured light power changes were originated with RBCs shape change induced by temperature rise due to the laser irradiation. A gentle peak following a slow descending was observed in the diffuse-reflected-light power history. This history might indicate the precursor state of the charring, in which the hemolysis might be considered to advance rapidly. We think that the measurement of diffuse-reflected-light power history might be able to detect precursor state of charring at the catheter-tip in blood.
21 CFR 870.5150 - Embolectomy catheter.
Code of Federal Regulations, 2010 CFR
2010-04-01
.... (a) Identification. An embolectomy catheter is a balloon-tipped catheter that is used to remove thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to...
Advanced Imaging Catheter: Final Project Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krulevitch, P; Colston, B; DaSilva, L
2001-07-20
Minimally invasive surgery (MIS) is an approach whereby procedures conventionally performed with large and potentially traumatic incisions are replaced by several tiny incisions through which specialized instruments are inserted. Early MIS, often called laparoscopic surgery, used video cameras and laparoscopes to visualize and control the medical devices, which were typically cutting or stapling tools. More recently, catheter-based procedures have become a fast growing sector of all surgeries. In these procedures, small incisions are made into one of the main arteries (e.g. femoral artery in the thigh), and a long thin hollow tube is inserted and positioned near the target area.more » The key advantage of this technique is that recovery time can be reduced from months to a matter of days. In the United States, over 700,000 catheter procedures are performed annually representing a market of over $350 million. Further growth in this area will require significant improvements in the current catheter technology. In order to effectively navigate a catheter through the tortuous vessels of the body, two capabilities must exist: imaging and positioning. In most cases, catheter procedures rely on radiography for visualization and manual manipulation for positioning of the device. Radiography provides two-dimensional, global images of the vasculature and cannot be used continuously due to radiation exposure to both the patient and physician. Intravascular ultrasound devices are available for continuous local imaging at the catheter tip, but these devices cannot be used simultaneously with therapeutic devices. Catheters are highly compliant devices, and manipulating the catheter is similar to pushing on a string. Often, a guide wire is used to help position the catheter, but this procedure has its own set of problems. Three characteristics are used to describe catheter maneuverability: (1) pushability -- the amount of linear displacement of the distal end (inside body) relative to an applied displacement of the proximal end (outside body); (2) torquability -- the amount of rotation of the distal end relative to an applied rotation of the proximal end; and (3) trackability -- the extent to which the catheter tracks along the guide wire without displacing it.« less
Lally, Frank; Soorani, Mitra; Woo, Timothy; Nayak, Sanjeev; Jadun, Changez; Yang, Ying; McCrudden, John; Naire, Shailesh; Grunwald, Iris; Roffe, Christine
2016-09-01
Mechanical thrombectomy with stent retriever devices is associated with significantly better outcomes than thrombolysis alone in the treatment of acute ischemic stroke. Thrombus aspiration achieves high patency rates, but clinical outcomes are variable. The aim of this study was to examine the effect of different suction conditions on perfusate flow during aspiration thrombectomy. A computational fluid dynamics model of an aspiration device within a patent and occluded blood vessel was used to simulate flow characteristics using fluid flow solver software. A physical particulate flow model of a patent vessel and a vessel occluded by thrombus was then used to visualize flow direction and measure flow rates with the aspiration catheter placed 1-10 mm proximal of the thrombus, and recorded on video. The mathematical model predicted that, in a patent vessel, perfusate is drawn from upstream of the catheter tip while, in an occluded system, perfusate is drawn from the vessel proximal to the device tip with no traction on the occlusion distal of the tip. The in vitro experiments confirmed the predictions of this model. In the occluded vessel aspiration had no effect on the thrombus unless the tip of the catheter was in direct contact with the thrombus. These experiments suggest that aspiration is only effective if the catheter tip is in direct contact with the thrombus. If the catheter tip is not in contact with the thrombus, aspirate is drawn from the vessels proximal of the occlusion. This could affect collateral flow in vivo. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
A linear stepping endovascular intervention robot with variable stiffness and force sensing.
He, Chengbin; Wang, Shuxin; Zuo, Siyang
2018-05-01
Robotic-assisted endovascular intervention surgery has attracted significant attention and interest in recent years. However, limited designs have focused on the variable stiffness mechanism of the catheter shaft. Flexible catheter needs to be partially switched to a rigid state that can hold its shape against external force to achieve a stable and effective insertion procedure. Furthermore, driving catheter in a similar way with manual procedures has the potential to make full use of the extensive experience from conventional catheter navigation. Besides driving method, force sensing is another significant factor for endovascular intervention. This paper presents a variable stiffness catheterization system that can provide stable and accurate endovascular intervention procedure with a linear stepping mechanism that has a similar operation mode to the conventional catheter navigation. A specially designed shape-memory polymer tube with water cooling structure is used to achieve variable stiffness of the catheter. Hence, four FBG sensors are attached to the catheter tip in order to monitor the tip contact force situation with temperature compensation. Experimental results show that the actuation unit is able to deliver linear and rotational motions. We have shown the feasibility of FBG force sensing to reduce the effect of temperature and detect the tip contact force. The designed catheter can change its stiffness partially, and the stiffness of the catheter can be remarkably increased in rigid state. Hence, in the rigid state, the catheter can hold its shape against a [Formula: see text] load. The prototype has also been validated with a vascular phantom, demonstrating the potential clinical value of the system. The proposed system provides important insights into the design of compact robotic-assisted catheter incorporating effective variable stiffness mechanism and real-time force sensing for intraoperative endovascular intervention.
Ahn, J H; Kim, I S; Shin, K M; Kang, S S; Hong, S J; Park, J H; Kim, H J; Lee, S H; Kim, D Y; Jung, J H
2016-03-01
Real-time ultrasound-guided infraclavicular proximal axillary venous catheterization is used in many clinical situations and provides the advantages of catheter stabilization, a reduced risk of catheter-related infection, and comfort for the patient without limitation of movement. However, unintended catheter tip dislocation and accidental arterial puncture occur occasionally. This study was designed to investigate the influence of arm position on catheter placement and complications. Patients were randomized to either the neutral group (n=240) or the abduction group (n=241). In the neutral group, patients were positioned with the head and shoulders placed in an anatomically neutral position and the arms kept by the side during catheterization. In the abduction group, the right upper arm was abducted at 90° from the trunk during catheterization. After real-time ultrasound-guided catheterization was carried out in the right infraclavicular proximal axillary vein, misplacement of the catheter and all complications were evaluated with ultrasound and chest radiography. The success rate of complete catheterization before evaluating the placement of the catheter was high in both groups (97.1 vs 98.8%, P=not significant). The incidence of accidental arterial puncture was not different (1.7 vs 0%, P=not significant). The incidence of misplacement of the catheter was higher in the neutral group than in the abduction group (3.9 vs 0.4%, P=0.01). There were no complications, such as haemothorax, pneumothorax, or injury to the brachial plexus and phrenic nerve, in either group. Upper arm abduction may minimize the risk of misplacement of the catheter during real-time ultrasound-guided infraclavicular proximal axillary venous catheterization. The trial was registered with the Clinical Trial Registry of Korea: https://cris.nih.go.kr/cris/index.jsp. Identifier: KCT0001417. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Hohert, Geoffrey; Pahlevaninezhad, Hamid; Lee, Anthony; Lane, Pierre M.
2016-03-01
Endoscopic catheter-based imaging systems that employ a 2-dimensional rotary or 3-dimensional rotary-pullback scanning mechanism require constant angular velocity at the distal tip to ensure correct angular registration of the collected signal. Non-uniform rotational distortion (NURD) - often present due to a variety of mechanical issues - can result in inconsistent position and velocity profiles at the tip, limiting the accuracy of any measurements. Since artifacts like NURD are difficult to identify and characterize during tissue imaging, phantoms with well-defined patterns have been used to quantify position and/or velocity error. In this work we present a fast, versatile, and cost-effective method for making fused deposition modeling 3D printed phantoms for identifying and quantifying NURD errors along an arbitrary user-defined pullback path. Eight evenly-spaced features are present at the same orientation at all points on the path such that deviations from expected geometry can be quantified for the imaging catheter. The features are printed vertically and then folded together around the path to avoid issues with printer head resolution. This method can be adapted for probes of various diameters and for complex imaging paths with multiple bends. We demonstrate imaging using the 3D printed phantoms with a 1mm diameter rotary-pullback OCT catheter and system as a means of objectively evaluating the mechanical performance of similarly constructed probes.
Architectural Analyses and Developments of 1 mm Diameter Micro Forceps for Catheter Surgery
NASA Astrophysics Data System (ADS)
Nokata, Makoto; Hashimoto, Yusuke; Obayashi, Takumi
Blockage in a blood vessel due to cardiovascular disease such as arteriosclerosis or aneurysms requires minimally invasive placement of a mesh tube or platinum coil stent via a catheter to open the affected area. Stents are positioned using a guide wire via a catheter, but the stent may be dropped on the way to its destination and requires much time in surgery, increasing the burden on the patient. Medical apparatuses are thus desired having a mechanism to grasp artifacts securely in blood vessels. We designed prototype microforceps for use on the end of a catheter for grasping operation in blood vessels and to contribute to medical apparatuses in this field. The microforceps we designed using a minimum number of parts uses metal injection molding (MIM) to realize strong mass production. Microforceps installed in the tip of a catheter. Stress analysis verified its capability to grasp, bend and turn within the confines of a blood vessels model.
Hartkamp, A; van Boxtel, A J; Zonnenberg, B A; Witteveen, P O
2000-12-01
Totally implantable venous access devices (TIVADs) are valuable instruments in case prolonged intravenous therapy is required, but implantation and use of these devices are associated with complications. The purpose of this study was to evaluate perioperative and long-term complications associated with TIVADs. In addition, we compared two different types of TIVADs with respect to implantation, care protocol and patients' comfort. In a retrospective study perioperative and long-term complications in a general oncology population were analysed. In a prospective randomized study comparison of two types of TIVADs was carried out. Perioperative complications occurred in 27 (21.4%) of 126 implanted TIVADs: catheter malposition (16.7%) in 21 patients, pneumothorax (0.8%) in one and haemorrhage (4.0%) in five. Long-term complications appeared in 31 (25.2%) out of 123 TIVADs: thrombosis in 9 (7.3%), especially associated with malposition of the tip of the catheter; infection in 10 (8.1%); extravasation in 2 (1.6%); migration of the catheter tip in 6 (4.8%); pain at reservoir in 3 (2.4%) and inaccessibility of the port in 1 (0.8%). No significant differences were found with respect to implantation, care accessibility and patients' comfort between the two TIVADs. The use of TIVADs is associated with some risk of serious perioperative and long-term complications. In case of thrombotic complications these systems can be saved with appropriate treatment. Correct positioning of the catheter tip is essential to prevent thrombotic complications. In case of TIVAD-related infectious complications, the possibility of saving the TIVAD depends on the causative microorganism and type of infection. Furthermore, to increase patients' satisfaction with TIVADs they should be well informed about the surgical procedure and possible disadvantages of these devices.
Duran, Cassidy; Estrada, Sean; O'Malley, Marcia; Sheahan, Malachi G; Shames, Murray L; Lee, Jason T; Bismuth, Jean
2015-12-01
Fundamental skills testing is now required for certification in general surgery. No model for assessing fundamental endovascular skills exists. Our objective was to develop a model that tests the fundamental endovascular skills and differentiates competent from noncompetent performance. The Fundamentals of Endovascular Surgery model was developed in silicon and virtual-reality versions. Twenty individuals (with a range of experience) performed four tasks on each model in three separate sessions. Tasks on the silicon model were performed under fluoroscopic guidance, and electromagnetic tracking captured motion metrics for catheter tip position. Image processing captured tool tip position and motion on the virtual model. Performance was evaluated using a global rating scale, blinded video assessment of error metrics, and catheter tip movement and position. Motion analysis was based on derivations of speed and position that define proficiency of movement (spectral arc length, duration of submovement, and number of submovements). Performance was significantly different between competent and noncompetent interventionalists for the three performance measures of motion metrics, error metrics, and global rating scale. The mean error metric score was 6.83 for noncompetent individuals and 2.51 for the competent group (P < .0001). Median global rating scores were 2.25 for the noncompetent group and 4.75 for the competent users (P < .0001). The Fundamentals of Endovascular Surgery model successfully differentiates competent and noncompetent performance of fundamental endovascular skills based on a series of objective performance measures. This model could serve as a platform for skills testing for all trainees. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Percutaneous implantation of a Port-Catheter System using the left subclavian artery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen Yong; He Xiaofeng; Chen Weiguo
2000-01-15
Purpose: To evaluate the safety and feasibility of a percutaneous Port-Catheter System (PCS) implanted via the subclavian artery (SCA) for regional chemotherapy or chemoembolization of thoracic, abdominal, and pelvic malignant tumors.Methods: Percutaneous puncture of the SCA was performed in 256 patients with thoracic, abdominal, or pelvic malignant tumors; then a catheter was inserted into the target artery. After the first transcatheter chemotherapy or chemoembolization with an emulsion of lipiodol and anticancer agents, an indwelling catheter was introduced with its tip placed in the target artery and its end subcutaneously connected to a port.Results: The procedure was successfully completed in allmore » 256 cases (100%). The indwelling catheter tip was satisfactorily placed in the target arteries in 242 cases (98%). Complications attributable to the procedure occurred in 20 (7.8%) cases, including pneumothorax (n=10, 4%), hemothorax (n=1, 0.4%), infections in the pocket (n=4, 1.6%), and hematoma at the puncture site (n=5, 2%). There were no severe sequelae or deaths. The duration of PCS usage was 1-36 months (median 9.5 months), During the course of treatment, occlusion of the target artery occurred in 20 cases (7.8%). Dislocation of the tip of the indwelling catheter occurred in 12 cases (4.7%); in 10 of the 12, the tip of the indwelling catheter was repositioned into the target artery. In all 10 cases no large symptomatic hematomas developed after the PCS was removed.Conclusion: Percutaneous PCS implantation via the left SCA, a relatively new procedure, is a safe and less invasive treatment approach than surgical placement for malignancies.« less
Percutaneous Implantation of a Port-Catheter System Using the Left Subclavian Artery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen Yong; He Xiaofeng; Chen Weiguo
2000-01-15
Purpose: To evaluate the safety and feasibility of a percutaneous Port-Catheter System (PCS) implanted via the subclavian artery (SCA) for regional chemotherapy or chemoembolization of thoracic, abdominal, and pelvic malignant tumors.Methods: Percutaneous puncture of the SCA was performed in 256 patients with thoracic, abdominal, or pelvic malignant tumors; then a catheter was inserted into the target artery. After the first transcatheter chemotherapy or chemoembolization with an emulsion of lipiodol and anticancer agents, an indwelling catheter was introduced with its tip placed in the target artery and its end subcutaneously connected to a port.Results: The procedure was successfully completed in allmore » 256 cases (100%). The indwelling catheter tip was satisfactorily placed in the target arteries in 242 cases (98%). Complications attributable to the procedure occurred in 20 (7.8%) cases, including pneumothorax (n = 10, 4%), hemothorax (n = 1, 0.4%), infections in the pocket (n = 4, 1.6%), and hematoma at the puncture site (n = 5, 2%). There were no severe sequelae or deaths. The duration of PCS usage was 1-36 months (median 9.5 months). During the course of treatment, occlusion of the target artery occurred in 20 cases (7.8%). Dislocation of the tip of the indwelling catheter occurred in 12 cases (4.7%); in 10 of the 12, the tip of the indwelling catheter was repositioned into the target artery. In all 10 cases no large symptomatic hematomas developed after the PCS was removed.Conclusion: Percutaneous PCS implantation via the left SCA, a relatively new procedure, is a safe and less invasive treatment approach than surgical placement for malignancies.« less
Hemodialysis Catheter Heat Transfer for Biofilm Prevention and Treatment.
Richardson, Ian P; Sturtevant, Rachael; Heung, Michael; Solomon, Michael J; Younger, John G; VanEpps, J Scott
2016-01-01
Central line-associated bloodstream infections (CLABSIs) are not easily treated, and many catheters (e.g., hemodialysis catheters) are not easily replaced. Biofilms (the source of infection) on catheter surfaces are notoriously difficult to eradicate. We have recently demonstrated that modest elevations of temperature lead to increased staphylococcal susceptibility to vancomycin and significantly soften the biofilm matrix. In this study, using a combination of microbiological, computational, and experimental studies, we demonstrate the efficacy, feasibility, and safety of using heat as an adjuvant treatment for infected hemodialysis catheters. Specifically, we show that treating with heat in the presence of antibiotics led to additive killing of Staphylococcus epidermidis with similar trends seen for Staphylococcus aureus and Klebsiella pneumoniae. The magnitude of temperature elevation required is relatively modest (45-50°C) and similar to that used as an adjuvant to traditional cancer therapy. Using a custom-designed benchtop model of a hemodialysis catheter, positioned with tip in the human vena cava as well as computational fluid dynamic simulations, we demonstrate that these temperature elevations are likely achievable in situ with minimal increased in overall blood temperature.
Thrombotic complications of implanted central venous access devices: prospective evaluation.
Labourey, Jean-Luc; Lacroix, Philippe; Genet, Dominique; Gobeaux, François; Martin, Jean; Venat-Bouvet, Laurence; Lavau-Denes, Sandrine; Maubon, Antoine; Tubiana-Mathieu, Nicole
2004-05-01
Implanted venous access devices (IVAD) are routinely used in oncologic patients. Thrombotic complication is a source of morbidity. During one year 246 patients with different solid neoplastic diseases received IVAD for chemotherapy administration. Two hundred forty-nine IVAD were placed percutaneously or by surgical cutdown. IVAD were flushed immediately after implantation with 3-5 mL of heparinized saline (100 U/mL). No monthly flush was required. A prospective evaluation of thrombotic complications was realised. in event of catheter dysfunction and/or clinical symptoms of phlebitis, a catheter opacification and/or a Doppler ultrasonography were performed. Twenty-three catheter dysfunctions were noted, corresponding to 13 catheter occlusions. Twelve patients presented clinical symptoms of phlebitis. Eleven venous thrombosis were diagnosed in this group; 10 by echo-Doppler and one by scanography. A unvaried statistic analysis using Fisher's test was performed to detect risk factors. Two factors were identified: the position of catheter tip above T4 (p < 0.001) and mediastinal or cervical lymph nodes larger than 6 cm (p < 0.001). The first increased the risk of catheter occlusion and the second increased the risk of phlebitis.
Feld, Gregory K
2004-11-01
Recent studies have demonstrated a high degree of efficacy of 8 mm electrode-tipped or saline-irrigated-tip catheters for ablation of atrial flutter (AFL). These catheters have a theoretical advantage as they produce a large ablation lesion. However, large-tip ablation catheters have a larger surface area and require a higher power radiofrequency (RF) generator with up to 100 W capacity to produce adequate ablation temperatures (50-60 degrees C). The potential advantages of a large-tip ablation catheter and high-power RF generator include the need for fewer energy applications, shorter procedure and fluoroscopy times, and greater efficacy. Therefore, the safety and efficacy of AFL ablation using 8 or 10 mm electrode catheters and a 100-W RF generator was studied using the Boston Scientific, Inc., EPT-1000 XP cardiac ablation system. There were 169 patients, aged 61 +/- 12 years involved. Acute end points were bidirectional isthmus block and no inducible AFL. Following ablation, patients were seen at 1, 3 and 6 months, with event monitoring performed weekly and for any symptoms. Three quality of life surveys were completed during follow-up. Acute success was achieved in 158 patients (93%), with 12 +/- 11 RF energy applications. The efficacy of 8 and 10 mm electrodes did not differ significantly. The number of RF energy applications (10 +/- 8 vs. 14 +/- 8) and ablation time (0.5 +/- 0.4 vs. 0.8 +/- 0.6 h) were less with 10 mm compared with 8 mm electrodes (p < 0.01). Of 158 patients with acute success, 42 were not evaluated at 6 months due to study exclusions. Of the 116 patients evaluated at 6 months, 112 (97%) had no AFL recurrence. Of those without AFL recurrence at 6 months, 95 and 93% were free of symptoms at 12 and 24 months, respectively. Ablation of AFL improved quality of life scores (p < 0.05) and reduced anti-arrhythmic and rate control drug use (p < 0.05). Complications occurred in six out of 169 patients (3.6%) but there were no deaths. It was concluded that ablation of AFL with 8 or 10 mm electrode catheters and a high-power RF generator was safe, effective and improved quality of life. The number and duration of RF applications was lower with 10 mm compared with 8 mm electrode catheters.
Intramuscular pressure varies with depth. The tibialis anterior muscle studied in 12 volunteers
NASA Technical Reports Server (NTRS)
Nakhostine, M.; Styf, J. R.; van Leuven, S.; Hargens, A. R.; Gershuni, D. H.
1993-01-01
Pressures in the tibialis anterior muscle were recorded at rest and during exercise with transducer-tipped catheters in 12 volunteers while they were supine or standing. The recordings were repeated with venous stasis created by an inflated tourniquet cuff on the thigh. Catheters were placed at 3 different sites in the muscle: catheter I adjacent to the deep surface of the fascia over the anterior compartment; catheter II between the fascia and the central tendon; and catheter III deep in the muscle close to the interosseous membrane. In both the supine and standing positions the intramuscular pressure at rest and the muscle relaxation pressure during exercise, obtained by catheter II, were greater than the corresponding pressures measured by the superficially located catheter I in the normal as well as in the volume loaded limb. The same conditions for pressure measurement consistently revealed lower pressures recorded by catheter III compared to II, but the difference was not significant. Our results indicate that intramuscular pressure increases centripetally, as the centrally lying tendon is approached. We conclude that pressure measurements for diagnosis of acute and chronic compartment syndromes and in ergonomic studies should be based on recordings from a standard location of the catheter within the muscle and a standard posture of the subject.
Vergara, Gaston R; Vijayakumar, Sathya; Kholmovski, Eugene G; Blauer, Joshua J E; Guttman, Mike A; Gloschat, Christopher; Payne, Gene; Vij, Kamal; Akoum, Nazem W; Daccarett, Marcos; McGann, Christopher J; Macleod, Rob S; Marrouche, Nassir F
2011-02-01
Magnetic resonance imaging (MRI) allows visualization of location and extent of radiofrequency (RF) ablation lesion, myocardial scar formation, and real-time (RT) assessment of lesion formation. In this study, we report a novel 3-Tesla RT -RI based porcine RF ablation model and visualization of lesion formation in the atrium during RF energy delivery. The purpose of this study was to develop a 3-Tesla RT MRI-based catheter ablation and lesion visualization system. RF energy was delivered to six pigs under RT MRI guidance. A novel MRI-compatible mapping and ablation catheter was used. Under RT MRI, this catheter was safely guided and positioned within either the left or right atrium. Unipolar and bipolar electrograms were recorded. The catheter tip-tissue interface was visualized with a T1-weighted gradient echo sequence. RF energy was then delivered in a power-controlled fashion. Myocardial changes and lesion formation were visualized with a T2-weighted (T2W) half Fourier acquisition with single-shot turbo spin echo (HASTE) sequence during ablation. RT visualization of lesion formation was achieved in 30% of the ablations performed. In the other cases, either the lesion was formed outside the imaged region (25%) or the lesion was not created (45%) presumably due to poor tissue-catheter tip contact. The presence of lesions was confirmed by late gadolinium enhancement MRI and macroscopic tissue examination. MRI-compatible catheters can be navigated and RF energy safely delivered under 3-Tesla RT MRI guidance. Recording electrograms during RT imaging also is feasible. RT visualization of lesion as it forms during RF energy delivery is possible and was demonstrated using T2W HASTE imaging. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
REAL TIME MRI GUIDED RADIOFREQUENCY ATRIAL ABLATION AND VISUALIZATION OF LESION FORMATION AT 3-TESLA
Vergara, Gaston R.; Vijayakumar, Sathya; Kholmovski, Eugene G.; Blauer, Joshua J.E.; Guttman, Mike A.; Gloschat, Christopher; Payne, Gene; Vij, Kamal; Akoum, Nazem W.; Daccarett, Marcos; McGann, Christopher J.; MacLeod, Rob S.; Marrouche, Nassir F.
2011-01-01
Background MRI allows visualization of location and extent of RF ablation lesion, myocardial scar formation, and real-time (RT) assessment of lesion formation. In this study, we report a novel 3-Tesla RT-MRI based porcine RF ablation model and visualization of lesion formation in the atrium during RF energy delivery. Objective To develop of a 3-Tesla RT-MRI based catheter ablation and lesion visualization system. Methods RF energy was delivered to six pigs under RT-MRI guidance. A novel MRI compatible mapping and ablation catheter was used. Under RT-MRI this catheter was safely guided and positioned within either the left or right atrium. Unipolar and bi-polar electrograms were recorded. The catheter tip-tissue interface was visualized with a T1-weighted gradient echo sequence. RF energy was then delivered in a power-controlled fashion. Myocardial changes and lesion formation were visualized with a T2-weighted (T2w) HASTE sequence during ablation. Results Real-time visualization of lesion formation was achieved in 30% of the ablations performed. In the other cases, either the lesion was formed outside the imaged region (25%) or lesion was not created (45%) presumably due to poor tissue-catheter tip contact. The presence of lesions was confirmed by late gadolinium enhancement (LGE) MRI and macroscopic tissue examination. Conclusion MRI compatible catheters can be navigated and RF energy safely delivered under 3-Tesla RT-MRI guidance. It is also feasible to record electrograms during RT imaging. Real-time visualization of lesion as it forms during delivery of RF energy is possible and was demonstrated using T2w HASTE imaging. PMID:21034854
Saber, W.; Moua, T.; Williams, E. C.; Verso, M.; Agnelli, G.; Couban, S.; Young, A.; De Cicco, M.; Biffi, R.; van Rooden, C. J.; Huisman, M. V.; Fagnani, D.; Cimminiello, C.; Moia, M.; Magagnoli, M.; Povoski, S. P.; Malak, S. F.; Lee, A. Y.
2010-01-01
Background Knowledge of independent, baseline risk factors of catheter-related thrombosis (CRT) may help select adult cancer patients at high risk to receive thromboprophylaxis. Objectives We conducted a meta-analysis of individual patient-level data to identify these baseline risk factors. Patients/Methods MEDLINE, EMBASE, CINAHL, CENTRAL, DARE, Grey literature databases were searched in all languages from 1995-2008. Prospective studies and randomized controlled trials (RCTs) were eligible. Studies were included if original patient-level data were provided by the investigators and if CRT was objectively confirmed with valid imaging. Multivariate logistic regression analysis of 17 prespecified baseline characteristics was conducted. Adjusted odds ratios (OR) and 95% confidence intervals (CI) were estimated. Results A total sample of 5636 subjects from 5 RCTs and 7 prospective studies was included in the analysis. Among these subjects, 425 CRT events were observed. In multivariate logistic regression, the use of implanted ports as compared with peripherally implanted central venous catheters (PICC), decreased CRT risk (OR = 0.43; 95% CI, 0.23-0.80), whereas past history of deep vein thrombosis (DVT) (OR = 2.03; 95% CI, 1.05-3.92), subclavian venipuncture insertion technique (OR = 2.16; 95% CI, 1.07-4.34), and improper catheter tip location (OR = 1.92; 95% CI, 1.22-3.02), increased CRT risk. Conclusions CRT risk is increased with using PICC catheters, previous history of DVT, subclavian venipuncture insertion technique and improper positioning of the catheter tip. These factors may be useful for risk stratifying patients to select those for thromboprophylaxis. Prospective studies are needed to validate these findings. PMID:21040443
Evolution of Force Sensing Technologies.
Shah, Dipen
2017-06-01
In order to Improve the procedural success and long-term outcomes of catheter ablation techniques for atrial fibrillation (AF), an Important unfulfilled requirement is to create durable electrophysiologically complete lesions. Measurement of contact force (CF) between the catheter tip and the target tissue can guide physicians to optimise both mapping and ablation procedures. Contact force can affect lesion size and clinical outcomes following catheter ablation of AF. Force sensing technologies have matured since their advent several years ago, and now allow the direct measurement of CF between the catheter tip and the target myocardium in real time. In order to obtain complete durable lesions, catheter tip spatial stability and stable contact force are important. Suboptimal energy delivery, lesion density/contiguity and/or excessive wall thickness of the pulmonary vein-left atrial (PV-LA) junction may result in conduction recovery at these sites. Lesion assessment tools may help predict and localise electrical weak points resulting in conduction recovery during and after ablation. There is increasing clinical evidence to show that optimal use of CF sensing during ablation can reduce acute PV re-conduction, although prospective randomised studies are desirable to confirm long-term favourable clinical outcomes. In combination with optimised lesion assessment tools, contact force sensing technology has the potential to become the standard of care for all patients undergoing AF catheter ablation.
Multimode intravascular RF coil for MRI-guided interventions.
Kurpad, Krishna N; Unal, Orhan
2011-04-01
To demonstrate the feasibility of using a single intravascular radiofrequency (RF) probe connected to the external magnetic resonance imaging (MRI) system via a single coaxial cable to perform active tip tracking and catheter visualization and high signal-to-noise ratio (SNR) intravascular imaging. A multimode intravascular RF coil was constructed on a 6F balloon catheter and interfaced to a 1.5T MRI scanner via a decoupling circuit. Bench measurements of coil impedances were followed by imaging experiments in saline and phantoms. The multimode coil behaves as an inductively coupled transmit coil. The forward-looking capability of 6 mm was measured. A greater than 3-fold increase in SNR compared to conventional imaging using optimized external coil was demonstrated. Simultaneous active tip tracking and catheter visualization was demonstrated. It is feasible to perform 1) active tip tracking, 2) catheter visualization, and 3) high SNR imaging using a single multimode intravascular RF coil that is connected to the external system via a single coaxial cable. Copyright © 2011 Wiley-Liss, Inc.
Multi-mode Intravascular RF Coil for MRI-guided Interventions
Kurpad, Krishna N.; Unal, Orhan
2011-01-01
Purpose To demonstrate the feasibility of using a single intravascular RF probe connected to the external MRI system via a single coaxial cable to perform active tip tracking and catheter visualization, and high SNR intravascular imaging. Materials and Methods A multi-mode intravascular RF coil was constructed on a 6F balloon catheter and interfaced to a 1.5T MRI scanner via a decoupling circuit. Bench measurements of coil impedances were followed by imaging experiments in saline and phantoms. Results The multi-mode coil behaves as an inductively-coupled transmit coil. Forward looking capability of 6mm is measured. Greater than 3-fold increase in SNR compared to conventional imaging using optimized external coil is demonstrated. Simultaneous active tip tracking and catheter visualization is demonstrated. Conclusions It is feasible to perform 1) active tip tracking, 2) catheter visualization, and 3) high SNR imaging using a single multi-mode intravascular RF coil that is connected to the external system via a single coaxial cable. PMID:21448969
Intravascular ultrasound in coronary atherosclerosis: a new approach to clinical assessment.
Liebson, P R; Klein, L W
1992-06-01
Intravascular ultrasound evaluation of the coronary arteries by means of a selective coronary catheter attached to an ultrasound unit has afforded precise depiction of coronary lumen diameter and area at the level of the catheter tip. The arterial wall at this level can be evaluated for lipid, fibrous tissue, calcification, wall dissections, and intraluminal thrombi. The technique has the advantage over coronary angioscopy and angiography in that it does not require infusions or injections to allow visualization, and it has the ability to depict the inside of the arterial wall. The current disadvantages include the inability to visualize the vessel segments distal to the catheter tip. Three-dimensional reconstruction techniques allow depiction of the segment of the artery traversed by the catheter tip. The use of Doppler ultrasound imaging provides information on coronary flow velocities through coronary obstructions. Intravascular ultrasound images may provide information that complements the coronary arteriogram and may have an impact on patient care and clinical investigation strategies.
Catheter tracking in an interventional photoacoustic surgical system
NASA Astrophysics Data System (ADS)
Cheng, Alexis; Itsarachaiyot, Yuttana; Kim, Younsu; Zhang, Haichong K.; Taylor, Russell H.; Boctor, Emad M.
2017-03-01
In laparoscopic medical procedures, accurate tracking of interventional tools such as catheters are necessary. Current practice for tracking catheters often involve using fluoroscopy, which is best avoided to minimize radiation dose to the patient and the surgical team. Photoacoustic imaging is an emerging imaging modality that can be used for this purpose and does not currently have a general tool tracking solution. Photoacoustic-based catheter tracking would increase its attractiveness, by providing both an imaging and tracking solution. We present a catheter tracking method based on the photoacoustic effect. Photoacoustic markers are simultaneously observed by a stereo camera as well as a piezoelectric element attached to the tip of a catheter. The signals received by the piezoelectric element can be used to compute its position relative to the photoacoustic markers using multilateration. This combined information can be processed to localize the position of the piezoelectric element with respect to the stereo camera system. We presented the methods to enable this work and demonstrated precisions of 1-3mm and a relative accuracy of less than 4% in four independent locations, which are comparable to conventional systems. In addition, we also showed in another experiment a reconstruction precision up to 0.4mm and an estimated accuracy up to 0.5mm. Future work will include simulations to better evaluate this method and its challenges and the development of concurrent photoacoustic marker projection and its associated methods.
Choi, Sun Young; Kim, Ah Hyun; Kim, Kyung Ah; Won, Jong Yun; Lee, Do Yun; Lee, Kwang-Hun
2010-01-01
We assessed the outcomes of a simplified technique for the percutaneous placement of a hepatic artery port-catheter system for chemotherapy infusion in advanced hepatocellular carcinoma with portal vein invasion. From February 2003 to February 2008, percutaneous hepatic artery port-catheter insertion was performed in 122 patients who had hepatocellular carcinoma with portal vein invasion. The arterial access route was the common femoral artery. The tip of the catheter was wedged into the right gastroepiploic artery without an additional fixation device. A side hole was positioned at the distal common hepatic artery to allow the delivery of chemotherapeutic agents into the hepatic arteries. Coil embolization was performed only to redistribute to the hepatic arteries or to prevent the inadvertent delivery of chemotherapeutic agents into extrahepatic arteries. The port chamber was created at either the supra-inguinal or infra-inguinal region. Technical success was achieved in all patients. Proper positioning of the side hole was checked before each scheduled chemotherapy session by port angiography. Catheter-related complications occurred in 19 patients (16%). Revision was achieved in 15 of 18 patients (83%). This simplified method demonstrates excellent technical feasibility, an acceptable range of complications, and is hence recommended for the management of advanced hepatocellular carcinoma with portal vein thrombosis.
Verification of intravenous catheter placement by auscultation--a simple, noninvasive technique.
Lehavi, Amit; Rudich, Utay; Schechtman, Moshe; Katz, Yeshayahu Shai
2014-01-01
Verification of proper placement of an intravenous catheter may not always be simple. We evaluated the auscultation technique for this purpose. Twenty healthy volunteers were randomized for 18G catheter inserted intravenously either in the right (12) or left arm (8), and subcutaneously in the opposite arm. A standard stethoscope was placed over an area approximately 3 cm proximal to the tip of the catheter in the presumed direction of the vein to grade on a 0-6 scale the murmur heard by rapidly injecting 2 mL of NaCl 0.9% solution. The auscultation was evaluated by a blinded staff anesthesiologist. All 20 intravenous injection were evaluated as flow murmurs, and were graded an average 5.65 (±0.98), whereas all 20 subcutaneous injections were evaluated as either crackles or no sound, and were graded an average 2.00 (±1.38), without negative results. Sensitivity was calculated as 95%. Specificity and Kappa could not be calculated due to an empty false-positive group. Being simple, handy and noninvasive, we recommend to use the auscultation technique for verification of the proper placement of an intravenous catheter when uncertain of its position. Data obtained in our limited sample of healthy subjects need to be confirmed in the clinical setting.
Frykholm, P; Pikwer, A; Hammarskjöld, F; Larsson, A T; Lindgren, S; Lindwall, R; Taxbro, K; Oberg, F; Acosta, S; Akeson, J
2014-05-01
Safe and reliable venous access is mandatory in modern health care, but central venous catheters (CVCs) are associated with significant morbidity and mortality, This paper describes current Swedish guidelines for clinical management of CVCs The guidelines supply updated recommendations that may be useful in other countries as well. Literature retrieval in the Cochrane and Pubmed databases, of papers written in English or Swedish and pertaining to CVC management, was done by members of a task force of the Swedish Society of Anaesthesiology and Intensive Care Medicine. Consensus meetings were held throughout the review process to allow all parts of the guidelines to be embraced by all contributors. All of the content was carefully scored according to criteria by the Oxford Centre for Evidence-Based Medicine. We aimed at producing useful and reliable guidelines on bleeding diathesis, vascular approach, ultrasonic guidance, catheter tip positioning, prevention and management of associated trauma and infection, and specific training and follow-up. A structured patient history focused on bleeding should be taken prior to insertion of a CVCs. The right internal jugular vein should primarily be chosen for insertion of a wide-bore CVC. Catheter tip positioning in the right atrium or lower third of the superior caval vein should be verified for long-term use. Ultrasonic guidance should be used for catheterisation by the internal jugular or femoral veins and may also be used for insertion via the subclavian veins or the veins of the upper limb. The operator inserting a CVC should wear cap, mask, and sterile gown and gloves. For long-term intravenous access, tunnelled CVC or subcutaneous venous ports are preferred. Intravenous position of the catheter tip should be verified by clinical or radiological methods after insertion and before each use. Simulator-assisted training of CVC insertion should precede bedside training in patients. Units inserting and managing CVC should have quality assertion programmes for implementation and follow-up of routines, teaching, training and clinical outcome. Clinical guidelines on a wide range of relevant topics have been introduced, based on extensive literature retrieval, to facilitate effective and safe management of CVCs. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Chik, William W B; Barry, M A; Malchano, Zach; Wylie, Bryan; Pouliopoulos, Jim; Huang, Kaimin; Lu, Juntang; Thavapalachandran, Sujitha; Robinson, David; Saadat, Vahid; Thomas, Stuart P; Ross, David L; Kovoor, Pramesh; Thiagalingam, Aravinda
2012-01-01
Radiofrequency (RF) ablation utilizing direct endocardial visualization (DEV) requires a "virtual electrode" to deliver RF energy while preserving visualization. This study aimed to: (1) examine the virtual electrode RF ablation efficacy; (2) determine the optimal power and duration settings; and (3) evaluate the utility of virtual electrode unipolar electrograms. The DEV catheter lesions were compared to lesions formed using a 3.5 mm open irrigated tip catheter within the right atria of 12 sheep. Generator power settings for DEV were titrated from 12W, 14W and 16W for 20, 30 and 40 seconds duration with 25 mL/min saline irrigation. Standard irrigated tip catheter settings of 30W, 50°C for 30 seconds and 30 mL/min were used. The DEV lesions were significantly greater in surface area and both major and minor axes compared to irrigated tip lesions (surface area 19.43 ± 9.09 vs 10.88 ± 4.72 mm, P<0.01) with no difference in transmurality (93/94 vs 46/47) or depth (1.86 ± 0.75 vs 1.85 ± 0.57 mm). Absolute electrogram amplitude reduction was greater for DEV lesions (1.89 ± 1.31 vs 1.49 ± 0.78 mV, P = 0.04), but no difference in percentage reduction. Pre-ablation pacing thresholds were not different between DEV (0.79 ± 0.36 mA) and irrigated tip (0.73 ± 0.25 mA) lesions. There were no complications noted during ablation with either catheter. Virtual electrode ablation consistently created wider lesions at lower power compared to irrigated tip ablation. Virtual electrode electrograms showed a comparable pacing and sensing efficacy in detecting local myocardial electrophysiological changes. © 2011 Wiley Periodicals, Inc.
Tip Design of Hemodialysis Catheters Influences Thrombotic Events and Replacement Rate.
Petridis, C; Nitschke, M; Lehne, W; Smith, E; Goltz, J P; Lehnert, H; Meier, M
2017-02-01
Central venous tunnelled hemodialysis catheters (CVTC) are used for initial vascular access in patients with renal failure. Tip design of the CVTC may play an important role in catheter function and complication rates, influencing adequate hemodialysis treatment of these patients. This prospective, observational cohort study compared the function and complication rates of two CVTCs in patients with end stage renal disease (ESRD) within a follow-up period of 24 months. The study included patients with ESRD who received either a CVTC with a split tip (ST) or a shotgun tip (SG). All patients underwent dialysis within 24 h of intervention. Blood flow was documented initially (Qb 0 ) and was followed up after 6 (Qb 6 ), 12 (Qb 12 ), and 24 (Qb 24 ) months. Analysis of blood flow and complication rates within the follow-up period was performed by questionnaires. In total, 185 patients were included, of whom 93 received a ST CVTC and 92 a SG CVTC. Baseline parameters did not differ significantly between groups. CVTC blood flow was not significantly different between the two devices. Thrombolytic therapy with Alteplase was used significantly more often in the ST group (29%) than in the SG group (16%) (p < 0.05). The CVTC replacement rate was significantly higher in the ST group (19.3%) compared with the SG group (8.7%) (p < 0.05). The tip design of CVTC (split or shotgun) appears to be irrelevant for long-term blood flow during dialysis treatment. However, patients may benefit from SG catheters over ST catheters where replacement rates and thrombolytic treatment are concerned. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Koa-Wing, Michael; Kojodjojo, Pipin; Malcolme-Lawes, Louisa C; Salukhe, Tushar V; Linton, Nick W F; Grogan, Aaron P; Bergman, Dale; Lim, Phang Boon; Whinnett, Zachary I; McCarthy, Karen; Ho, Siew Yen; O'Neill, Mark D; Peters, Nicholas S; Davies, D Wyn; Kanagaratnam, Prapa
2009-12-01
Robotic remote catheter ablation potentially provides improved catheter-tip stability, which should improve the efficiency of radiofrequency energy delivery. Percentage reduction in electrogram peak-to-peak voltage has been used as a measure of effectiveness of ablation. We tested the hypothesis that improved catheter-tip stability of robotic ablation can diminish signals to a greater degree than manual ablation. In vivo NavX maps of 7 pig atria were constructed. Separate lines of ablation were performed robotically and manually, recording pre- and postablation peak-to-peak voltages at 10, 20, 30, and 60 seconds and calculating signal amplitude reduction. Catheter ablation settings were constant (25W, 50 degrees , 17 mL/min, 20-30 g catheter tip pressure). The pigs were sacrificed and ablation lesions correlated with NavX maps. Robotic ablation reduced signal amplitude to a greater degree than manual ablation (49 +/- 2.6% vs 29 +/- 4.5% signal reduction after 1 minute [P = 0.0002]). The mean energy delivered (223 +/- 184 J vs 231 +/- 190 J, P = 0.42), power (19 +/- 3.5 W vs 19 +/- 4 W, P = 0.84), and duration of ablation (15 +/- 9 seconds vs 15 +/- 9 seconds, P = 0.89) was the same for manual and robotic. The mean peak catheter-tip temperature was higher for robotic (45 +/- 5 degrees C vs 42 +/- 3 degrees C [P < 0.0001]). The incidence of >50% signal reduction was greater for robotic (37%) than manual (21%) ablation (P = 0.0001). Robotically assisted ablation appears to be more effective than manual ablation at signal amplitude reduction, therefore may be expected to produce improved clinical outcomes.
Percutaneous transfemoral repositioning of malpositioned central venous catheters.
Hartnell, G G; Roizental, M
1995-04-01
Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.
Elsharkawy, Hesham; Sonny, Abraham; Govindarajan, Srinivasa Raghavan; Chan, Vincent
2017-05-01
Epidural anesthesia and analgesia has a reported failure rate ranging from 13% to 32%. We describe a technique using colour Doppler and M-mode ultrasonography to determine the position of the epidural catheter after placement in adults. This retrospective review included 37 adult patients who received postoperative epidural analgesia and underwent technically difficult epidural catheter placement. The demographic characteristics, type of surgery, use of ultrasonography, method of insertion, intervertebral level, and success of epidural localization using colour Doppler were noted for each patient. Pain scores on postoperative day 1 and the presence of a patchy block were also reviewed. Colour Doppler study helped to indicate the catheter's path from the skin to the epidural space during saline injection in 33 patients (89%). Saline flow within the epidural space (catheter tip confirmation) was successfully detected with colour Doppler in 25 patients (67.5%) and with M-mode ultrasonography in 28 patients (75%). Appropriate dermatomal analgesia was noted in 35 patients (94.5%) during local anesthetic infusion. Our preliminary data suggest the feasibility of using colour Doppler and M-mode ultrasonography to confirm proper epidural catheter placement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, W; Damato, A; Viswanathan, A
2014-06-15
Purpose: To develop a novel active MR-tracking system which can provide accurate and rapid localization of brachytherapy catheters, and assess its reliability and spatial accuracy in comparison to standard catheter digitization using MR images. Methods: An active MR tracker for brachytherapy was constructed by adding three printed-circuit micro-coils to the shaft of a commercial metallic stylet. A gel phantom with an embedded framework was built, into which fifteen 14-Gauge catheters were placed, following either with parallel or crossed paths. The tracker was inserted sequentially into each catheter, with MR-tracking running continuously. Tracking was also performed during the tracker's removal frommore » each catheter. Catheter trajectories measured from the insertion and the removal procedures using the same micro-coil were compared, as well as trajectories obtained using different micro-coils. A 3D high-resolution MR image dataset of the phantom was acquired and imported into a treatment planning system (TPS) for catheter digitization. A comparison between MR-tracked positions and positions digitized from MR images by TPS was performed. Results: The MR tracking shows good consistency for varying catheter paths and for all micro-coils (mean difference ∼1.1 mm). The average distance between the MR-tracking trajectory and catheter digitization from the MR images was 1.1 mm. Ambiguity in catheter assignment from images due to crossed paths was resolved by active tracking. When tracking was interleaved with imaging, real-time images were continuously acquired at the instantaneous tip positions and displayed on an external workstation. Conclusion: The active MR tracker may be used to provide an independent measurement of catheter location in the MR environment, potentially eliminating the need for subsequent CT. It may also be used to control realtime imaging of catheter placement. This will enable MR-based brachytherapy planning of interstitial implants without ionizing radiation, with the potential to enable dosimetric guidance of catheter placement. We gratefully acknowledge support from the American Heart Association SDG 10SDG2610139, NIH 1R21CA158987-01A1, U41-RR019703, and R21 CA 167800, as well as a BWH Department of Radiation Oncology post-doctoral fellowship support. Li Pan and Wesley Gilson are employees of Siemens Corporation, Corporate Technology. Ravi Seethamraju is an employee of Siemens Healthcare.« less
Risk factors and possible mechanisms of superior vena cava intravenous port malfunction.
Wu, Ching-Yang; Hu, Han-Chung; Ko, Po-Jen; Fu, Jui-Ying; Wu, Ching-Feng; Liu, Yun-Hen; Li, Hao-Jui; Kao, Tsung-Chi; Kao, Kuo-Chin; Yu, Sheng-Yueh; Chang, Chee-Jen; Hsieh, Hong-Chang
2012-05-01
To identify the risk factors leading to catheter malfunction. Reliable venous access is crucial for cancer patients. Malfunction of intravenous ports may lead to discontinuation of treatment and repeated interventions. We retrospectively reviewed the independent risk factors for catheter malfunction among patients receiving intravenous port implantations. A total of 1508 procedures were included from the calendar year 2006, and clinical data and chest plain films were analyzed. The patients were followed-up until June 30, 2010. For patients still alive, the last outpatient follow-up date was considered as the end point. For the remaining patients, the date of death or discharge against advice was considered as the end points. The risk factors for catheter malfunction were then evaluated. The intervention-free periods of the malfunction group and nonmalfunction group were 317 and 413 days, respectively. Statistical analyses showed that the Nut-Catheter Angle was the only risk factor for catheter malfunction (P = 0.001). A logistic model also confirmed that the Nut-Catheter Angle was the only risk factor for catheter malfunction (P < 0.001). Valve tip catheters were not advantageous with regard to catheter malfunction prevention as compared to open tip catheters. A smaller Nut-Catheter Angle had a greater risk for catheter malfunction. Catheter impingement caused by inadequate pocket creation and port implantation lead to compromised catheter lumen and difficulty flushing. The possibility of retained blood and medications increased thin thrombotic biofilm formation and medication precipitation. Catheter malfunctions can be avoided by using proper surgical techniques and adequate maintenance.
Central venous catheterization for parenteral nutrition.
Padberg, F T; Ruggiero, J; Blackburn, G L; Bistrian, B R
1981-01-01
To define the risks associated with central venous catheterization for total parenteral nutrition (TPN) 3291 patient days of this therapy, delivered by an established nutrition support team, were evaluated. One hundred and seventy-five catheters placed in 104 patients were reviewed over an 18 month period. Positive cultures were reported on 11 cannulae for a 6.4% incidence of colonization; five catheters (2.8%) were considered septic. Pleural or mediastinal complications of subclavian or internal jugular venipuncture occurred in eight patients (4.8%). Misdirection of the catheter tip occurred in 11.5% of insertions. Five patients (4.8%) had clinically apparent thrombosis in the superior vena cava, innominate and/or subclavian veins during hospitalization; four others had evidence of thrombosis at autopsy examination, giving an incidence of 8.7% in the entire series. No death directly resulted from the use of this therapy. Compliance with a rigid protocol by an experienced team can allow safe and effective use of central venous catheters and parenteral nutrition therapy. PMID:6782956
Kovarovic, Brandon; Woo, Henry H; Fiorella, David; Lieber, Baruch B; Sadasivan, Chander
2018-03-01
Cerebral angiography involves the antegrade injection of contrast media through a catheter into the vasculature to visualize the region of interest under X-ray imaging. Depending on the injection and blood flow parameters, the bolus of contrast can propagate in the upstream direction and proximal to the catheter tip, at which point contrast is said to have refluxed. In this in vitro study, we investigate the relationship of fundamental hemodynamic variables to this phenomenon. Contrast injections were carried out under steady and pulsatile flow using various vessel diameters, catheter sizes, working fluid flow rates, and injection rates. The distance from the catheter tip to the proximal edge of the contrast bolus, called reflux length, was measured on the angiograms; the relation of this reflux length to different hemodynamic parameters was evaluated. Results show that contrast reflux occurs when the pressure distal to the catheter tip increases to be greater than the pressure proximal to the catheter tip. The ratio of this pressure difference to the baseline flow rate, called reflux resistance here, was linearly correlated to the normalized reflux length (reflux length/vessel diameter). Further, the ratio of blood flow to contrast fluid momentums, called the Craya-Curtet number, was correlated to the normalized reflux length via a sigmoid function. A sigmoid function was also found to be representative of the relationship between the ratio of the Reynolds numbers of blood flow to contrast and the normalized reflux length. As described by previous reports, catheter based contrast injections cause substantial increases in local flow and pressure. Contrast reflux should generally be avoided during standard antegrade angiography. Our study shows two specific correlations between contrast reflux length and baseline and intra-injection parameters that have not been published previously. Further studies need to be conducted to fully characterize the phenomena and to extract reliable indicators of clinical utility. Parameters relevant to cerebral angiography are studied here, but the essential principles are applicable to all angiographic procedures involving antegrade catheter injections.
Abdelaal Ahmed Mahmoud, Ahmed; El-Shafei, Hassan Ismail; Yassin, Hany Mahmoud; Elramely, Mohamed Adly; Abdelhaq, Mohamed Mohamed; El Kady, Hany Wafiq; Awada, Wael Nabil Fahemy
2017-06-01
Antegrade cannulation of peripheral veins is the usual practice. Blood stasis between a catheter and the wall of the vein or at its tip in addition to catheter-induced phlebitis may initiate a thrombosis. The use of retrograde ventriculojugular shunts against the direction of the blood flow with resultant decrease in the incidence of venous thrombosis encouraged us to compare retrograde versus conventional antegrade peripheral venous cannulation. Monocentric, nonblinded, prospective observational cohort of 40 intensive care unit patients receiving 2 peripheral venous catheters in upper limbs, 1 inserted in the direction of blood flow (antegrade cannula) and the other inserted in an opposite direction to blood flow (retrograde cannula). Daily ultrasound assessment of the angle between the catheter and the vascular wall was done to detect onset and progression of thrombus formation. The study included 40 patients, aged 46.7 ± 10.132 years. The incidence of thrombus formation was 100% in both techniques. The onset time of thrombus formation between the catheter and the wall of a vein was significantly longer with the retrograde catheters than with the antegrade catheters with median time (interquartile range [range]) 6 days (5-6.75 [4-8]) with 95% confidence interval (CI), 5.58-6.42 vs 3 days (3-4 [2-5]) with 95% CI (2.76-3.24), respectively, with a P value <.001. The time needed by the recently detected thrombus to reach the catheter tip determined by ultrasound with or without catheter failure was significantly longer in the retrograde catheters than in the antegrade catheter with median time (interquartile range [range]) 9 days (8-9 [7-10]) with 95% CI, 8.76-9.24 vs 4 days (4-5 [3-6]) with 95% CI, 3.76-4.24, respectively, with a P value <.001. Retrograde cannulation did not decrease the incidence of thrombus formation, but significantly increased the onset time until thrombus formation and prolonged the time needed by the newly formed thrombus to reach the catheter tip compared with conventional antegrade cannulation.
Fredrickson, Michael J
2008-01-01
Neurostimulation during single shot interscalene block has a significant false negative motor response rate. Compared with tangential needle approaches for single shot block, interscalene catheter (ISC) placement commonly involves Tuohy needles inserted longitudinally to the brachial plexus. This study aimed to determine the sensitivity of neurostimulation during ultrasound-guided ISC needle placement, and the feasibility of an ultrasound-guided ISC needle endpoint. One hundred fifty-five consecutive nonstimulating ISCs were placed with the needle tip position confirmed by the sonographic spread of 5 mL dextrose 5%. Catheter advancement was then blind 2 to 3 cm past the needle tip. A 0.8 mA electrical stimulus at 2 Hz was applied throughout. When a satisfactory image was obtained, neurostimulation was ignored and the minimum motor response amplitude noted. If imaging was equivocal, a brief appropriate motor response at 0.8 mA was sought. A sustained response at <0.5 mA was only sought if imaging was suboptimal. Prior to surgery conducted under general anesthesia, 30 mL ropivacaine 0.5% was administered through the ISC. Catheter success was defined as a recovery room numerical rating pain score of =2 (scale, 0-10). In 57% of patients, a muscle response was not elicited. An ultrasound needle endpoint was used in 92% of ISC placements, of which 96% were successful. Sustained twitches at <0.5 mA were obtained in 12 (8%) patients, 6 (4%) of these deliberately sought because of suboptimal imaging. Catheter success overall was 95%. This study suggests that the false negative motor response rate for longitudinal ISC needle placement is higher than the false negative response rate associated with tangential needle approach interscalene block. An ultrasound guided ISC needle endpoint is a feasible alternative to a neurostimulation endpoint.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Damato, Antonio L., E-mail: adamato@lroc.harvard.edu; Viswanathan, Akila N.; Don, Sarah M.
2014-10-15
Purpose: To investigate the use of a system using electromagnetic tracking (EMT), post-processing and an error-detection algorithm for detecting errors and resolving uncertainties in high-dose-rate brachytherapy catheter digitization for treatment planning. Methods: EMT was used to localize 15 catheters inserted into a phantom using a stepwise acquisition technique. Five distinct acquisition experiments were performed. Noise associated with the acquisition was calculated. The dwell location configuration was extracted from the EMT data. A CT scan of the phantom was performed, and five distinct catheter digitization sessions were performed. No a priori registration of the CT scan coordinate system with the EMTmore » coordinate system was performed. CT-based digitization was automatically extracted from the brachytherapy plan DICOM files (CT), and rigid registration was performed between EMT and CT dwell positions. EMT registration error was characterized in terms of the mean and maximum distance between corresponding EMT and CT dwell positions per catheter. An algorithm for error detection and identification was presented. Three types of errors were systematically simulated: swap of two catheter numbers, partial swap of catheter number identification for parts of the catheters (mix), and catheter-tip shift. Error-detection sensitivity (number of simulated scenarios correctly identified as containing an error/number of simulated scenarios containing an error) and specificity (number of scenarios correctly identified as not containing errors/number of correct scenarios) were calculated. Catheter identification sensitivity (number of catheters correctly identified as erroneous across all scenarios/number of erroneous catheters across all scenarios) and specificity (number of catheters correctly identified as correct across all scenarios/number of correct catheters across all scenarios) were calculated. The mean detected and identified shift was calculated. Results: The maximum noise ±1 standard deviation associated with the EMT acquisitions was 1.0 ± 0.1 mm, and the mean noise was 0.6 ± 0.1 mm. Registration of all the EMT and CT dwell positions was associated with a mean catheter error of 0.6 ± 0.2 mm, a maximum catheter error of 0.9 ± 0.4 mm, a mean dwell error of 1.0 ± 0.3 mm, and a maximum dwell error of 1.3 ± 0.7 mm. Error detection and catheter identification sensitivity and specificity of 100% were observed for swap, mix and shift (≥2.6 mm for error detection; ≥2.7 mm for catheter identification) errors. A mean detected shift of 1.8 ± 0.4 mm and a mean identified shift of 1.9 ± 0.4 mm were observed. Conclusions: Registration of the EMT dwell positions to the CT dwell positions was possible with a residual mean error per catheter of 0.6 ± 0.2 mm and a maximum error for any dwell of 1.3 ± 0.7 mm. These low residual registration errors show that quality assurance of the general characteristics of the catheters and of possible errors affecting one specific dwell position is possible. The sensitivity and specificity of the catheter digitization verification algorithm was 100% for swap and mix errors and for shifts ≥2.6 mm. On average, shifts ≥1.8 mm were detected, and shifts ≥1.9 mm were detected and identified.« less
Helms, Adam; West, J Jason; Patel, Amit; Mounsey, J Paul; DiMarco, John P; Mangrum, J Michael; Ferguson, John D
2009-02-01
Atrioesophageal fistula is a rare complication of atrial fibrillation (AF) ablation that should be avoided. We investigated whether rotational intracardiac echocardiography (ICE) can help to minimize ablation close to the esophagus. We studied 41 patients referred for catheter ablation of refractory AF. A rotational ICE catheter was inserted into the (LA) to determine the location of the esophagus. The esophagus was identified to be either adjacent to the pulmonary vein (PV) ostium or to a cuff 2 cm outside the ostium. Circumferential ablation was performed at the PV ostium, with the exact ablation location determined by ICE. The relationship of the catheter tip to the esophagus was imaged during energy delivery, allowing interruption when respiration moved the tip closer to the esophagus. Out of 41 patients, the esophagus was seen near left-sided PVs in 32 and near right-sided PVs in three patients. The median distance from LA endocardium to esophagus was 2.2 mm (range, 1.4-6 mm). In 21 of 35 patients with a closely related esophagus, ablation over the esophagus was avoided by ablating either lateral or medial to the esophagus. In 14 patients, the esophagus could not be avoided, and risk was minimized by limiting lesion size. Significant movement (>10 mm) of the esophagus during the procedure occurred in 3/41 cases. Rotational ICE can accurately determine the distance of ablation sites from the esophagus. Real-time imaging of the relationship of the ablation catheter tip to the esophagus may reduce the incidence of esophageal injury.
Teng, Yi; Ou, Mengchan; Yu, Hai
2018-02-01
To compare the transesophageal echocardiography (TEE) probe as a surface probe with the vascular probe for guiding internal jugular vein (IJV) catheterization. Prospective, randomized, controlled pilot study. University hospital. One hundred cardiac surgery patients, including 50 adult and 50 pediatric patients. Patients in the TEE probe group received right IJV catheterization using the TEE probe, while the vascular probe group used the vascular probe for catheterization. The puncture time, first-attempt success rate, quality of the imaging with needle tip positioning, wire positioning, and catheter positioning were recorded. The incidence of complication or any adverse event also was observed. Adult patients: In the vascular probe group, the success rate for first attempt IJV catheterization was 24/25 (96%), while in the TEE probe group, the success rate for first attempt IJV catheterization was 25/25 (100%). There was no statistical difference in the puncture time, image quality, needle tip positioning, wire positioning, and catheter positioning between groups (p > 0.05). Pediatric patients: The success rate for first-attempt IJV catheterization was 100% in both groups, and there were no statistical differences in the puncture time, image quality, and positioning between the 2 groups (p > 0.05). No complications or adverse events were observed in either group. The TEE probe, used as a surface probe, can be used to guide IJV puncturing and catheterization in cardiac surgery patients with favorable feasibility and safety. Copyright © 2018 Elsevier Inc. All rights reserved.
Arokiaraj, Mark Christopher
2018-02-01
Difficulty in engaging with guide catheters is not uncommon in acute emergencies. We aimed to evaluate the use of Cordis ® INFINITI diagnostic catheters to perform angioplasty in patients in whom the coronaries cannot be engaged using standard guide catheters. In 34 cases of acute coronary syndrome, when difficulty in engagement with two standard guide catheters was encountered with reasonable manipulations, angioplasty was performed using diagnostic catheters. In total, 40 stents were placed by this technique. Pushability and trackability, distal tip flexion and three-point bending tests were performed to evaluate the performance of the guide and diagnostic catheters. Angioplasty was performed easily in a setting where it would have been very difficult to perform. Coronary dissection occurred in one patient, treated by a stent. The stent and dilatation balloons were easily passed through the diagnostic catheters. Pressure tracings were clearly preserved with certain stent delivery systems, and at angioplasty, although there was slightly reduced opacification of the respective artery, the coronary anatomy was sufficiently visualized to perform angioplasty. No periprocedural target lesion complications were seen in any cases. Pushability and trackability tests showed good force transmission along a tortuous path with diagnostic catheters, and balanced force-displacement curves from three-point bending tests and distal tip softness tests. Angioplasty with stenting can be performed safely through 6F Cordis ® infiniti diagnostic catheters when difficulty in engaging guide catheters is encountered. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.
Ganji, Yusof; Janabi-Sharifi, Farrokh; Cheema, Asim N
2011-12-01
Despite the recent advances in catheter design and technology, intra-cardiac navigation during electrophysiology procedures remains challenging. Incorporation of imaging along with magnetic or robotic guidance may improve navigation accuracy and procedural safety. In the present study, the in vivo performance of a novel remote controlled Robot Assisted Cardiac Navigation System (RACN) was evaluated in a porcine model. The navigation catheter and target sensor were advanced to the right atrium using fluoroscopic and intra-cardiac echo guidance. The target sensor was positioned at three target locations in the right atrium (RA) and the navigation task was completed by an experienced physician using both manual and RACN guidance. The navigation time, final distance between the catheter tip and target sensor, and variability in final catheter tip position were determined and compared for manual and RACN guided navigation. The experiments were completed in three animals and five measurements recorded for each target location. The mean distance (mm) between catheter tip and target sensor at the end of the navigation task was significantly less using RACN guidance compared with manual navigation (5.02 ± 0.31 vs. 9.66 ± 2.88, p = 0.050 for high RA, 9.19 ± 1.13 vs. 13.0 ± 1.00, p = 0.011 for low RA and 6.77 ± 0.59 vs. 15.66 ± 2.51, p = 0.003 for tricuspid valve annulus). The average time (s) needed to complete the navigation task was significantly longer by RACN guided navigation compared with manual navigation (43.31 ± 18.19 vs. 13.54 ± 1.36, p = 0.047 for high RA, 43.71 ± 11.93 vs. 22.71 ± 3.79, p = 0.043 for low RA and 37.84 ± 3.71 vs. 16.13 ± 4.92, p = 0.003 for tricuspid valve annulus. RACN guided navigation resulted in greater consistency in performance compared with manual navigation as evidenced by lower variability in final distance measurements (0.41 vs. 0.99 mm, p = 0.04). This study demonstrated the safety and feasibility of the RACN system for cardiac navigation. The results demonstrated that RACN performed comparably with manual navigation, with improved precision and consistency for targets located in and near the right atrial chamber. Copyright © 2011 John Wiley & Sons, Ltd.
SU-C-9A-05: A Medical Physics Approach to the Evaluation of a New Anti-Reflux Catheter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pasciak, A; McElmurray, J
2014-06-01
Purpose: The Surefire Infusion System (SIS) is a coaxial microcatheter system with a pliant expanding tip designed to limit retrograde flow of administered intra-arterial embolic agents and resultant non-target embolization (NTE). A recent study suggests that the SIS may achieve relative arterial hypotension downstream to the catheter tip when compared to an end-hole catheter, potentially altering microsphere distribution. We have used a physics based approach to evaluate particulate distribution using both the SIS and standard end-hole microcatheter via a two-step same-day injection of Tc-99m MAA as a microsphere surrogate. Methods: Informed patient consent and IRB approval were obtained. Four patientsmore » with primary or secondary liver cancer underwent two sequential low-particulate infusions of Tc-99m MAA on the same day using both the SIS and a conventional end-hole catheter. Radiopharmaceutical dosages of approximately 1:8 were utilized in the first infusion relative to the second to eliminate the effect of residual activity on the images acquired after each step. SPECT imaging was obtained following each infusion, and MAA distribution was analyzed and compared. Archived fluoroscopic images confirmed near-identical catheter position for both infusions. Results: SPECT images from all four patients demonstrate qualitatively increased penetration of MAA distal to the site of infusion using the SIS when compared to a standard end-hole catheter. Quantitative evaluations corroborate these findings with some distal regions receiving between 33% to more than 200% greater relative activity when SIS was used. No appreciable NTE was identified in either patient subset. Conclusion: These preliminary data demonstrate the validity of this dual-infusion technique. Both qualitative and quantitative assessment of SPECT images and comparison with baseline contrast enhanced CT and PET/CT images indicate an improvement in MAA penetration into the target lesion with the SIS. However, the degree of improvement is highly dependent on tumor type and size. Financial support provided by Surefire Medical.« less
Basic principles for measurement of intramuscular pressure
NASA Technical Reports Server (NTRS)
Hargens, A. R.; Ballard, R. E.
1995-01-01
We review historical and methodological approaches to measurements of intramuscular pressure (IMP) in humans. These techniques provide valuable measures of muscle tone and activity as well as diagnostic criteria for evaluation of exertional compartment syndrome. Although the wick and catheter techniques provide accurate measurements of IMP at rest, their value for exercise studies and diagnosis of exertional compartment syndrome is limited because of low frequency response and hydrostatic (static and inertial) pressure artifacts. Presently, most information on diagnosis of exertional compartment syndromes during dynamic exercise is available using the Myopress catheter. However, future research and clinical diagnosis using IMP can be optimized by the use of a miniature transducer-tipped catheter such as the Millar Mikro-tip.
Bak, Jimmy; Jørgensen, Thomas M; Helfmann, Jurgen; Gravemann, Ute; Vorontsova, Inessa
2011-01-01
We have demonstrated that it is possible to launch UVC LED light into bacterial contaminated polymer tubes/catheters and disinfect the intraluminal space of these tubes. This can be achieved by UVC treatment of the catheters on a regular basis. Catheters are in the distal end equipped with an exit hole for administration of drugs, bloods or nutrients into the bloodstream. Even if the UVC light is strongly attenuated during its propagation through the catheter tube a fraction of the UVC launched into the catheter will escape through the exit hole and irradiate the blood. We demonstrate by calculations that very small effective doses are exposed to the blood (ca 10(-4) J m(-2)). This dosage level is very low compared with UVC doses reported from other therapeutic applications. The very short residence time of the blood constituents in the irradiated volume in front of the exit hole is the main reason why the UVC exposure to the blood in the catheter application is so low. The very low dose received by the blood through the catheter tip indicated that possible side effects are negligible and makes the UV disinfection technique feasible in a clinical setting. © 2011 Jimmy Bak. Photochemistry and Photobiology © 2011 The American Society of Photobiology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou Jun; Sebastian, Evelyn; Mangona, Victor
2013-02-15
Purpose: In order to increase the accuracy and speed of catheter reconstruction in a high-dose-rate (HDR) prostate implant procedure, an automatic tracking system has been developed using an electromagnetic (EM) device (trakSTAR, Ascension Technology, VT). The performance of the system, including the accuracy and noise level with various tracking parameters and conditions, were investigated. Methods: A direct current (dc) EM transmitter (midrange model) and a sensor with diameter of 1.3 mm (Model 130) were used in the trakSTAR system for tracking catheter position during HDR prostate brachytherapy. Localization accuracy was assessed under both static and dynamic analyses conditions. For themore » static analysis, a calibration phantom was used to investigate error dependency on operating room (OR) table height (bottom vs midposition vs top), sensor position (distal tip of catheter vs connector end of catheter), direction [left-right (LR) vs anterior-posterior (AP) vs superior-inferior (SI)], sampling frequency (40 vs 80 vs 120 Hz), and interference from OR equipment (present vs absent). The mean and standard deviation of the localization offset in each direction and the corresponding error vectors were calculated. For dynamic analysis, the paths of five straight catheters were tracked to study the effects of directions, sampling frequency, and interference of EM field. Statistical analysis was conducted to compare the results in different configurations. Results: When interference was present in the static analysis, the error vectors were significantly higher at the top table position (3.3 {+-} 1.3 vs 1.8 {+-} 0.9 mm at bottom and 1.7 {+-} 1.0 mm at middle, p < 0.001), at catheter end position (3.1 {+-} 1.1 vs 1.4 {+-} 0.7 mm at the tip position, p < 0.001), and at 40 Hz sampling frequency (2.6 {+-} 1.1 vs 2.4 {+-} 1.5 mm at 80 Hz and 1.8 {+-} 1.1 at 160 Hz, p < 0.001). So did the mean offset errors in the LR direction (-1.7 {+-} 1.4 vs 0.4 {+-} 0.5 mm in AP and 0.8 {+-} 0.8 mm in SI directions, p < 0.001). The error vectors were significantly higher with surrounding interference (2.2 {+-} 1.3 mm) vs without interference (1.0 {+-} 0.7 mm, p < 0.001). An accuracy of 1.6 {+-} 0.2 mm can be reached when using optimum configuration (160 Hz at middle table position). When interference was present in the dynamic tracking, the mean tracking errors in LR direction (1.4 {+-} 0.5 mm) was significantly higher than that in AP direction (0.3 {+-} 0.2 mm, p < 0.001). So did the mean vector errors at 40 Hz (2.1 {+-} 0.2 mm vs 1.3 {+-} 0.2 mm at 80 Hz and 0.9 {+-} 0.2 mm at 160 Hz, p < 0.05). However, when interference was absent, they were comparable in the both directions and at all sampling frequencies. An accuracy of 0.9 {+-} 0.2 mm was obtained for the dynamic tracking when using optimum configuration. Conclusions: The performance of an EM tracking system depends highly on the system configuration and surrounding environment. The accuracy of EM tracking for catheter reconstruction in a prostate HDR brachytherapy procedure can be improved by reducing interference from surrounding equipment, decreasing distance from transmitter to tracking area, and choosing appropriated sampling frequency. A calibration scheme is needed to further reduce the tracking error when the interference is high.« less
Percutaneous Pulmonary Embolism Thrombectomy and Thrombolysis: Technical Tips and Tricks.
Devcic, Zlatko; Kuo, William T
2018-06-01
Catheter-directed therapy (CDT) is now acknowledged as a treatment option for select patients with acute massive or submassive pulmonary embolism (PE), and more patients are being considered for CDT if there is available expertise. Therefore, interventionalists should be aware of the variety of catheter-based treatment options, specific pitfalls to avoid during therapy, and the appropriate treatment endpoints. This article reviews currently available techniques and protocols for treating acute massive and submassive PE, with tips to safely and successfully perform percutaneous PE interventions.
USAFSAM Review and Analysis of Radiofrequency Radiation Bioeffects Literature. Fifth Report.
1985-03-01
exteriorized between the scapulae. The tip of the catheter was positioned at the juncture between the superior and inferior venae cavae . With this preparation...other than in connection with a definitely Government-related procure- ment, the United States Government incurs no responsibility or any obligation...Between experimental sessions, Frey and Seifert measured the power density with a quarter-wave dipole connected to a commercial thermistor and power meter
Hamada, L; Saito, K; Yoshimura, H; Ito, K
2000-01-01
In this paper, the microwave interstitial antenna with the dielectric load in part near the tip is introduced to realize the tip-heating and to improve the dependence of the heating patterns on the insertion depth. Numerical simulations using the Finite Difference Time Domain (FDTD) method have been conducted at the frequency of 915 MHz for four different configurations of the coaxial-slot antenna inserted into a catheter: the media between the antenna and the catheter are (a) no, (b) a thin air layer, (c) a thin dielectric layer, and (d) a thin air layer and a dielectric load in part near the tip. The diameter of the antenna including the catheter is sufficiently small for minimally invasive therapy. Comparison of the SARs for the four configurations makes it clear that the dielectric-loaded antenna can realize the best tip-heating and suppress the hot spot near the surface of the human body. Dependence of the SAR distributions on the insertion depth of the antenna has also been examined. It is found from the investigation that the dielectric-loaded antenna has little dependence on the insertion depth.
Flexible robotics: a new paradigm.
Aron, Monish; Haber, Georges-Pascal; Desai, Mihir M; Gill, Inderbir S
2007-05-01
The use of robotics in urologic surgery has seen exponential growth over the last 5 years. Existing surgical robots operate rigid instruments on the master/slave principle and currently allow extraluminal manipulations and surgical procedures. Flexible robotics is an entirely novel paradigm. This article explores the potential of flexible robotic platforms that could permit endoluminal and transluminal surgery in the future. Computerized catheter-control systems are being developed primarily for cardiac applications. This development is driven by the need for precise positioning and manipulation of the catheter tip in the three-dimensional cardiovascular space. Such systems employ either remote navigation in a magnetic field or a computer-controlled electromechanical flexible robotic system. We have adapted this robotic system for flexible ureteropyeloscopy and have to date completed the initial porcine studies. Flexible robotics is on the horizon. It has potential for improved scope-tip precision, superior operative ergonomics, and reduced occupational radiation exposure. In the near future, in urology, we believe that it holds promise for endoluminal therapeutic ureterorenoscopy. Looking further ahead, within the next 3-5 years, it could enable transluminal surgery.
Simon, Scott Douglas; Grey, Casey Paul
2014-04-01
The Penumbra system uses a coaxial separator and continuous extracorporeal suction to remove a clot from a cerebral artery. Forced-suction thrombectomy (FST) involves aspirating clots through the same reperfusion catheter using only a syringe, decreasing the procedure time and supplies needed. To evaluate multiple combinations of catheters and syringes to determine the optimal pairing for use in FST. Tests were performed using both the Penumbra system and syringes to aspirate water through Penumbra 0.041 inch (041), 4Max, 0.054 inch (054) and 5Max reperfusion catheters and a shuttle sheath. Dynamic pressure and flow at the catheter tip were calculated from the fill times for each system. Static pressure and force for each aspiration source were determined with a vacuum gauge. All syringes provided significantly higher dynamic pressure at the catheter tip than the Penumbra system (p<0.001). Increasing syringe volume significantly increased static pressure (p<0.001). Both flow and aspiration force significantly increased with catheter size (p<0.001). Cases are presented to demonstrate the clinical value of the laboratory principles. Maximizing static and dynamic pressure when performing FST is achieved by aspirating with a syringe possessing both the largest volume and the largest inlet diameter available. Maximizing aspiration force and flow rate is achieved by using the largest catheter possible.
Catheter-tip force transducer for cardiovascular research
NASA Technical Reports Server (NTRS)
Feldstein, C.; Lewis, G. W.; Silver, R. H.; Culler, V. H.
1975-01-01
Sensor can be installed in left ventricle by means of procedures available for inserting catheter into an artery at body's extremities and manipulating it through vessel and past aortic valve. Metallic tines of device can be used as internal electrode for electrocardiogram.
Kocuria kristinae: a true pathogen in pediatric patients.
Chen, Hsin-Mao; Chi, Hsin; Chiu, Nan-Chang; Huang, Fu-Yuan
2015-02-01
Kocuria kristinae is a Gram-positive microorganism, which has rarely been reported as a pathogen that causes infection in humans. Recently, a few studies had concluded that this pathogen can indeed cause infection in immunocompromised hosts. However, the number of reports on K. kristinae infection in pediatric patients is still relatively limited. Clinical data on pediatric patients who had K. kristinae cells isolated from their blood specimens during the period from January 2008 to May 2012 in a tertiary-care hospital in northern Taiwan were gathered and analyzed. Among 12 patients with K. kristinae cells isolated from their blood specimens, laboratory test results confirmed seven to have K. kristinae bloodstream infection. Six of them were premature babies, and one had acute leukemia. The infections were all healthcare associated. All the six premature babies had clinical presentation of sepsis and were inserted with percutaneous central venous catheters. One patient had two sets of blood culture positive for K. kristinae infection, and two premature patients had two sets of K. kristinae isolated, one from blood culture and the other from catheter tip culture, both of which were done at the same time. The leukemic child was inserted with a Broviac catheter and had K. kristinae isolated from both blood specimen and Broviac catheter. In the remaining five patients, K. kristinae infection was considered to be contaminant because they had only one set of positive blood culture and had other recognized infections. K. kristinae can cause infections in premature babies and immunocompromised pediatric patients using long-term intravenous catheters. Therefore, K. kristinae should be considered as a true pathogen and proper treatment should be provided to all susceptible pediatric patients. Copyright © 2013. Published by Elsevier B.V.
Moore, Harold L; Twardowski, Zbylut J
2003-10-01
Soft, cuffed indwelling catheters are used for hemodialysis access and intravenous infusions. The majority of these catheters are removed as a result of infection caused by contamination of the catheter hub during the connection/disconnection procedures. To prevent clot formation in the lumen, these catheters are routinely "locked" with heparin or some other anticoagulant. None of the anticoagulants commonly used as locking solutions demonstrates any significant bactericidal properties. The primary goal of this study was the development of a catheter locking method that retains anticoagulant properties at the catheter tip and bactericidal properties at the catheter hub. The second goal was to find a solution that possesses excellent bactericidal properties but is not detrimental in the event of injection into the patient's blood stream. The bactericidal properties of acidified, concentrated saline (ACS) were compared to concentrated trisodium citrate and to commonly used bactericidal agents such as povidone iodine, sodium hypochlorite, and chlorhexidine. In preliminary studies, the rate of diffusion of solutes was measured in glass tubes. In another set of experiments, the mixing of two solutions (anticoagulant and bactericide) separated by an air bubble ("air-bubble method") was observed in stationary and moving systems. The final series of studies compared the bactericidal properties of ACS to other bactericidal solutions mentioned above. The solutions diffused swiftly in the glass tubes, and by the third day, both solutions were mixed. The air-bubble method prevented mixing in both stationary and moving systems. The bactericidal properties of ACS were superior to all other tested solutions. The proposed method of catheter locking with anticoagulant at the catheter tip and ACS at the catheter hub separated by an air bubble is a promising technique and clinical studies are warranted.
Minilaparotomy salvage of malfunctioning catheters in peritoneal dialysis.
Li, Jian-Ri; Cheng, Chi-Hung; Chiu, Kun-Yuan; Cheng, Chen-Li; Yang, Chi-Rei; Ho, Hao-Chung; Ko, Jiunn-Liang; Ou, Yen-Chuan
2013-01-01
Catheter malfunction is a common and significant complication during peritoneal dialysis (PD). We developed a minilaparotomy procedure to rescue malfunctioning catheters and to prevent recurrence of malfunction. From 2006 to 2011, 11 patients receiving PD had a malfunctioning catheter. In all patients, a 2-cm incision, 5 cm caudally to the previous peritoneal entry site was used to correct the malfunctioning catheter, with concomitant fixation of the catheter to the peritoneum. Catheter tip migration occurred in 7 patients, omental wrapping in 3, and blood clot obstruction in 1. The mean onset time to catheter malfunction was 197.5 days (range: 4 - 1270 days), and the mean operating time was 41 minutes (range: 35 - 56 minutes). There was no recurrence of catheter malfunction and no surgery-related peritonitis. Our minilaparotomy procedure is safe and feasible for the salvage of malfunctioning PD catheters.
Roca-Luque, Ivo; Rivas, Nuria; Francisco, Jaume; Perez, Jordi; Acosta, Gabriel; Oristrell, Gerard; Terricabres, Maria; Garcia-Dorado, David; Moya, Angel
2017-01-01
Ablation in aortic cusps could be necessary in up to 15% of the patients, especially in para-Hisian atrial tachycardia and ventricular arrhythmias arising from outflow tracts. Risk of coronary damage has led to recommendation of systematic coronary angiography (CA) during the procedure. Other image tests as intravascular (ICE) or transesophageal echocardiography (TEE) have been proposed. Both methods have limitations: additional vascular access for ICE and need for additional CA in some patients in case of TEE. We describe an alternative method to assess relation of catheter tip and coronary ostia during ablation in aortic cusps without additional vascular accesses by performing selective angiography with the ablation catheter. We prospectively evaluated 12 consecutive patients (69.3 ± 8.5, 6 female) who underwent ablation in right (1), left (5), and noncoronary cusps (6). We performed angiography through the ablation cooled tip radiofrequency catheter at the ablation site. Ablation was effective in 91.6% of the patients (3 patients needed additional ablation out of coronary cusps: pulmonary cusp, right ventricular outflow tract (RVOT), and coronary sinus and 1 patient underwent a second procedure because recurrence). No complications occurred neither during procedure nor follow-up (6.2 ± 3.8 months). No technical problems occurred with the ablation catheter after contrast injection. Selective angiography through a cooled-tip radiofrequency ablation catheter is feasible to assess relation of coronary ostia and ablation site when ablation in aortic cusps. It allows continuous real-time assessment of this relation, avoids the need for additional vascular accesses and no complications occurred in our series. © 2016 Wiley Periodicals, Inc.
Parameter Optimization of Pseudo-Rigid-Body Models of MRI-Actuated Catheters
Greigarn, Tipakorn; Liu, Taoming; Çavuşoğlu, M. Cenk
2016-01-01
Simulation and control of a system containing compliant mechanisms such as cardiac catheters often incur high computational costs. One way to reduce the costs is to approximate the mechanisms with Pseudo-Rigid-Body Models (PRBMs). A PRBM generally consists of rigid links connected by spring-loaded revolute joints. The lengths of the rigid links and the stiffnesses of the springs are usually chosen to minimize the tip deflection differences between the PRBM and the compliant mechanism. In most applications, only the relationship between end load and tip deflection is considered. This is obviously not applicable for MRI-actuated catheters which is actuated by the coils attached to the body. This paper generalizes PRBM parameter optimization to include loading and reference points along the body. PMID:28261009
Piek, J; Raes, P
1996-01-01
We described a new ventricular catheter that is the combination of a "classic" ventricular catheter with a piezo-resistive transducer at its tip. The device allows parallel recordings of intraventricular fluid pressure via a chip and a fluid-filled external transducer, drainage of cerebrospinal fluid from the ventricle or injection of fluid into the ventricle with simultaneous monitoring of intracranial pressure, and recording of brain tissue pressure in cases of misplacement or dislocation of the ventricular catheter or in cases of progressively narrowing ventricles caused by brain edema. Clinical tests in various situations at different pressure ranges (total recording time, 1356 h in 13 patients) gave excellent correlations of both pressures. Application of the device is especially indicated in clinical situations in which pressure-controlled drainage is desirable, occlusion of ventricular bolts is likely, or pressure-volume tests are needed.
Cystoscopic temporary ureteral catheterization during radical vaginal and abdominal trachelectomy.
Abu-Rustum, Nadeem R; Sonoda, Yukio; Black, Destin; Chi, Dennis S; Barakat, Richard R
2006-11-01
To describe the role of temporary retrograde ureteral catheterization at the time of fertility-sparing radical vaginal or abdominal trachelectomy in women with early-stage cervical cancer. We analyzed a prospectively maintained database of all patients with cervical cancer who were explored for radical vaginal or abdominal trachelectomy at our institution. Cystourethroscopy and ureteral catheterization were performed prior to the vaginal or abdominal operation in all patients, except two pediatric ones. Temporary bilateral retrograde ureteral catheters were planned for all patients as part of our routine procedure to facilitate identification of the distal ureters. 5Fr whistle-tip or open-ended catheters were used and usually advanced to approximately 20 cm. Catheters were removed at the end of the operation in all cases. All catheters were inserted by a gynecologic oncology fellow or attending. Between 11/01 and 12/05, 40 patients were taken to the operating room for planned fertility-sparing radical vaginal or abdominal trachelectomy. We previously reported on two pediatric patients; they are excluded from this report. The median age for adult patients was 32 years (mean, 31.6; range, 23-40). International Federation of Gynecology and Obstetrics (FIGO) stage included IB1 (26), IA2 (6), and IA1 with lymphovascular invasion (6). Thirty-four patients underwent radical vaginal trachelectomy and four underwent a radical abdominal trachelectomy. Two (5%) of 38 patients required immediate completion radical hysterectomy due to extensive endocervical disease (one in the vaginal group and one in the abdominal group). Bilateral ureteral catheters were inserted successfully in 37 (97%) of 38 patients and facilitated identification of the distal ureter during the dissection. In one case, the right ureteral orifice could not be successfully catheterized, and the case was completed with unilateral catheterization. The estimated time to perform this part of the operation was approximately 15-20 min. Twenty-eight patients (74%) had 5Fr whistle-tip ureteral catheters inserted, and 10 had open-ended catheters inserted. There were no intraoperative complications. Median hospital stay was 3 days (range, 3-7). Hematuria, evident in the drainage bag attached to the Foley catheter, usually resolved in 24-48 h. Two (20%) of 10 patients who had open-ended catheters inserted developed a transient rise in postoperative creatinine (1.7 and 3.5 mg/dl, respectively) compared to 0/28 patients who had whistle-tip catheters placed (P<0.001). Both were attributed to postoperative distal ureteral edema, and only one patient required reinsertion of temporary ureteral stents. No patient developed long-term urinary complications or fistulae. Cystourethroscopy and bilateral retrograde ureteral catheterization by gynecologic oncologists is a simple and quick procedure that may facilitate identifying the distal ureter during radical vaginal or abdominal trachelectomy. We favor using 5Fr whistle-tip catheters as they may be associated with less ureteral mucosal trauma and subsequent postoperative edema. The skills needed for this procedure should be available to fellows in gynecologic oncology training.
Rossetti, Francesca; Pittiruti, Mauro; Lamperti, Massimo; Graziano, Ugo; Celentano, Davide; Capozzoli, Giuseppe
2015-01-01
The Italian Group for Venous Access Devices (GAVeCeLT) has carried out a multicenter study investigating the safety and accuracy of intracavitary electrocardiography (IC-ECG) in pediatric patients. We enrolled 309 patients (age 1 month-18 years) candidate to different central venous access devices (VAD) - 56 peripherally inserted central catheters (PICC), 178 short term centrally inserted central catheters (CICC), 65 long term VADs, 10 VADs for dialysis - in five Italian Hospitals. Three age groups were considered: A (<4 years, n = 157), B (4-11 years, n = 119), and C (12-18 years, n = 31). IC-ECG was applicable in 307 cases. The increase of the P wave on IC-ECG was detected in all cases but two. The tip of the catheter was positioned at the cavo-atrial junction (CAJ) (i.e., at the maximal height of the P wave on IC-ECG) and the position was checked during the procedure by fluoroscopy or chest x-ray, considering the CAJ at 1-2 cm (group A), 1.5-3 cm (group B), or 2-4 cm (group C) below the carina. There were no complications related to IC-ECG. The overall match between IC-ECG and x-ray was 95.8% (96.2% in group A, 95% in group B, and 96.8% in group C). In 95 cases, the IC-ECG was performed with a dedicated ECG monitor, specifically designed for IC-ECG (Nautilus, Romedex): in this group, the match between IC-ECG and x-ray was 98.8%. We conclude that the IC-ECG method is safe and accurate in the pediatric patients. The applicability of the method is 99.4% and its feasibility is 99.4%. The accuracy is 95.8% and even higher (98.8%) when using a dedicated ECG monitor.
Quick, Harald H; Zenge, Michael O; Kuehl, Hilmar; Kaiser, Gernot; Aker, Stephanie; Massing, Sandra; Bosk, Silke; Ladd, Mark E
2005-02-01
Active instrument visualization strategies for interventional MR angiography (MRA) require vascular instruments to be equipped with some type of radiofrequency (RF) coil or dipole RF antenna for MR signal detection. Such visualization strategies traditionally necessitate a connection to the scanner with either coaxial cable or laser fibers. In order to eliminate any wire connection, RF resonators that inductively couple their signal to MR surface coils were implemented into catheters to enable wireless active instrument visualization. Instrument background to contrast-to-noise ratio was systematically investigated as a function of the excitation flip angle. Signal coupling between the catheter RF coil and surface RF coils was evaluated qualitatively and quantitatively as a function of the catheter position and orientation with regard to the static magnetic field B0 and to the surface coils. In vivo evaluation of the instruments was performed in interventional MRA procedures on five pigs under MR guidance. Cartesian and projection reconstruction TrueFISP imaging enabled simultaneous visualization of the instruments and vascular morphology in real time. The implementation of RF resonators enabled robust visualization of the catheter curvature to the very tip. Additionally, the active visualization strategy does not require any wire connection to the scanner and thus does not hamper the interventionalist during the course of an intervention.
Evaluation of robotic endovascular catheters for arch vessel cannulation.
Riga, Celia V; Bicknell, Colin D; Hamady, Mohamad S; Cheshire, Nicholas J W
2011-09-01
Conventional catheter instability and embolization risk limits the adoption of endovascular therapy in patients with challenging arch anatomy. This study investigated whether arch vessel cannulation can be enhanced by a remotely steerable robotic catheter system. Seventeen clinicians with varying endovascular experience cannulated all arch vessels within two computed tomography-reconstructed pulsatile flow phantoms (bovine type I and type III aortic arches), under fluoroscopic guidance, using conventional and robotic techniques. Quantitative (catheterization times, catheter tip movements, vessel wall hits, catheter deflection) and qualitative metrics (Imperial College Complex Endovascular Cannulation Scoring Tool [IC3ST]) performance scores were compared. Robotic catheterization techniques resulted in a significant reduction in median carotid artery cannulation times and the median number of catheter tip movements for all vessels. Vessel wall contact with the aortic arch wall was reduced to a median of zero with robotic catheters. During stiff guidewire exchanges, robotic catheters maintained stability with zero deflection, independent of the distance the catheter was introduced into the carotid vessels. Overall IC3ST performance scores (interquartile range) were significantly improved using the robotic system: Type I arch score was 26/35 (20-30.8) vs 33/35 (31-34; P = .001), and type III arch score was 20.5/35 (16.5-28.5) vs 26.5/35 (23.5-28.8; P = .001). Low- and medium-volume interventionalists demonstrated an improvement in performance with robotic cannulation techniques. The high-volume intervention group did not show statistically significant improvement, but cannulation times, movements, and vessel wall hits were significantly reduced. Robotic technology has the potential to reduce the time, risk of embolization and catheter dislodgement, radiation exposure, and the manual skill required for carotid and arch vessel cannulation, while improving overall performance scores. Copyright © 2011 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Damato, AL; Bhagwat, MS; Buzurovic, I
Purpose: To investigate the use of a system using EM tracking, postprocessing and error-detection algorithms for measuring brachytherapy catheter locations and for detecting errors and resolving uncertainties in treatment-planning catheter digitization. Methods: An EM tracker was used to localize 13 catheters in a clinical surface applicator (A) and 15 catheters inserted into a phantom (B). Two pairs of catheters in (B) crossed paths at a distance <2 mm, producing an undistinguishable catheter artifact in that location. EM data was post-processed for noise reduction and reformatted to provide the dwell location configuration. CT-based digitization was automatically extracted from the brachytherapy planmore » DICOM files (CT). EM dwell digitization error was characterized in terms of the average and maximum distance between corresponding EM and CT dwells per catheter. The error detection rate (detected errors / all errors) was calculated for 3 types of errors: swap of two catheter numbers; incorrect catheter number identification superior to the closest position between two catheters (mix); and catheter-tip shift. Results: The averages ± 1 standard deviation of the average and maximum registration error per catheter were 1.9±0.7 mm and 3.0±1.1 mm for (A) and 1.6±0.6 mm and 2.7±0.8 mm for (B). The error detection rate was 100% (A and B) for swap errors, mix errors, and shift >4.5 mm (A) and >5.5 mm (B); errors were detected for shifts on average >2.0 mm (A) and >2.4 mm (B). Both mix errors associated with undistinguishable catheter artifacts were detected and at least one of the involved catheters was identified. Conclusion: We demonstrated the use of an EM tracking system for localization of brachytherapy catheters, detection of digitization errors and resolution of undistinguishable catheter artifacts. Automatic digitization may be possible with a registration between the imaging and the EM frame of reference. Research funded by the Kaye Family Award 2012.« less
The mixability of angiographic contrast with arterial blood
Lieber, Baruch B.; Sadasivan, Chander; Hao, Qing; Seong, Jaehoon; Cesar, Liliana
2009-01-01
Purpose: Angiographic contrast that is routinely injected into arteries is used not only to evaluate arterial geometry but also in many cases to assess perfusion. The authors conducted two experiments to examine the dispersion of angiographic contrast injected antegradely into an artery under conditions similar to those found in selective (carotid artery) or superselective (circle of Willis) angiography in order to determine the distance from the catheter tip at which the contrast can be considered fully mixed with the blood. A third experiment investigated whether the contrast once mixed with blood will separate from the mixture under the gravitational field due to a density mismatch. Methods: Experiment I—Under high-speed angiographic acquisition, a bolus of contrast was injected through a catheter along the flow direction of a blood analog fluid flowing through a straight, long, cylindrical tube. The variation in grayscale intensity along the length of the tube was acquired and modeled as the step response to a second-order system. The distance from the catheter tip at which the contrast mixes with the working fluid, the mixing length, was determined as the length along the tube after which the step response settles to within 3% of the steady state value. Experiment II—A bolus of angiographic contrast was injected at rates varying from 0.1 to 1 cc∕s through three different catheter sizes in the left common carotid artery of three rabbits. The average cross-sectional grayscale intensity over one cardiac cycle was calculated at four locations along the artery: Immediately distal to the catheter tip, at location of maximum grayscale intensity, and at 10 and 20 arterial diameters from the catheter tip. The status of mixing within 10 arterial diameters was assessed by differences between the grayscale value at this location and that at the maximum and 20 arterial diameter location. Experiment III—Angiographic contrast was premixed by agitation in three separate vials containing normal saline, canine blood, and glycerol∕distilled-water mixture. The vials were then stationed vertically and angiographic images obtained every 5 min for 1 h. The average intensity of contrast along the vertical length of each vial was obtained for every time point to record any changes in the distribution of contrast over time. Results: The first experiment shows that angiographic contrast completely mixes with steady flowing blood analog fluid within about eight tube diameters of the injection site. The second experiment shows that contrast completely mixes with blood within ten arterial diameters under appropriate injection parameters. The third experiment shows that angiographic contrast does not separate from, or settle out of, contrast-carrying fluid mixtures for a period of 1 h. Conclusions: The results demonstrate that under typical injection conditions in the clinical setting, contrast issuing from the catheter completely mixes with the blood within ten artery diameters downstream of the catheter tip. Once mixed, it does not separate from the blood due to gravity. PMID:19994517
Evaluation of epidural and peripheral nerve catheter heating during magnetic resonance imaging.
Owens, Sean; Erturk, M Arcan; Ouanes, Jean-Pierre P; Murphy, Jamie D; Wu, Christopher L; Bottomley, Paul A
2014-01-01
Many epidural and peripheral nerve catheters contain conducting wire that could heat during magnetic resonance imaging (MRI), requiring removal for scanning. We tested 2 each of 6 brands of regional analgesia catheters (from Arrow International [Reading, Pennsylvania], B. Braun Medical Inc [Bethlehem, Pennsylvania], and Smiths Medical/Portex [Keene, New Hampshire]) for exposure to clinical 1.5- and 3-T MRI. Catheters testing as nonmagnetic were placed in an epidural configuration in a standard human torso-sized phantom, and an MRI pulse sequence applied at the maximum scanner-allowed radiofrequency specific absorption rate (SAR) for 15 minutes. Temperature and SAR exposure were sampled during MRI using multiple fiberoptic temperature sensors. Two catheters (the Arrow StimuCath Peripheral Nerve and B. Braun Medical Perifix FX Epidural) were found to be magnetic and not tested further. At 3 T, exposure of the remaining 3 epidural and 1 peripheral nerve catheter to the scanner's maximum RF exposure elicited anomalous heating of 4°C to 7°C in 2 Arrow Epidural (MultiPort and Flex-Tip Plus) catheters at the entry points. Temperature increases for the other catheters at 3 T, and all catheters at 1.5 T were 1.4°C or less. When normalized to the body-average US Food and Drug Administration guideline SAR of 4 W/kg, maximum projected temperature increases were 0.1°C to 2.5°C at 1.5 T and 0.7°C to 2.7°C at 3 T, except for the Arrow MultiPort Flex-Tip Plus catheter at 3 T whose increase was 14°C. Most but not all catheters can be left in place during 1.5-T MRI scans. Heating of less than 3°C during MRI for most catheters is not expected to be injurious. While heating was lower at 1.5 T versus 3 T, performance differences between products underscore the need for safety testing before performing MRI.
Evaluation of Epidural and Peripheral Nerve Catheter Heating During Magnetic Resonance Imaging
Owens, Sean; Erturk, M. Arcan; Ouanes, Jean-Pierre P.; Murphy, Jamie D.; Wu, Christopher L.; Bottomley, Paul A.
2014-01-01
Background Many epidural and peripheral nerve catheters contain conducting wire that could heat during magnetic resonance imaging (MRI), requiring removal for scanning. Methods We tested 2 each of 6 brands of regional analgesia catheters (from Arrow International, B. Braun Medical, and Smiths Medical/Portex) for exposure to clinical 1.5 and 3 Tesla (T) MRI. Catheters testing as non-magnetic were placed in an epidural configuration in a standard human torso-sized phantom, and an MRI pulse sequence applied at the maximum scanner-allowed radio frequency (RF) specific absorption rate (SAR) for 15 minutes Temperature and SAR exposure were sampled during MRI using multiple fiber-optic temperature sensors. Results Two catheters (the Arrow StimuCath Peripheral Nerve, and Braun Medical Perifix FX Epidural) were found to be magnetic and not tested further. At 3T, exposure of the remaining 3 epidural and 1 peripheral nerve catheter to the scanner’s maximum RF exposure, elicited anomalous heating of 4 to 7°C in 2 Arrow Epidural (MultiPort and Flex-Tip Plus) catheters at the entry points. Temperature increases for the other catheters at 3T and all catheters at 1.5T were ≤1.4°C. When normalized to the body-average FDA guideline SAR of 4W/kg, maximum projected temperature increases were 0.1 to 2.5°C at 1.5T and 0.7 to 2.7°C at 3T, except for the Arrow MultiPort Flex-Tip Plus catheter at 3T whose increase was 14°C. Conclusions Most but not all catheters can be left in place during 1.5T MRI scans. Heating of <3°C during MRI for most catheters is not expected to be injurious. While heating was lower at 1.5T vs 3T, performance differences between products underscore the need for safety testing before performing MRI. PMID:25275576
Stephens, Douglas N.; Truong, Uyen T.; Nikoozadeh, Amin; Oralkan, Ömer; Seo, Chi Hyung; Cannata, Jonathan; Dentinger, Aaron; Thomenius, Kai; de la Rama, Alan; Nguyen, Tho; Lin, Feng; Khuri-Yakub, Pierre; Mahajan, Aman; Shivkumar, Kalyanam; O’Donnell, Matt; Sahn, David J.
2012-01-01
Objectives The primary objective was to test in vivo for the first time the general operation of a new multifunctional intracardiac echocardiography (ICE) catheter constructed with a microlinear capacitive micromachined ultrasound transducer (ML-CMUT) imaging array. Secondarily, we examined the compatibility of this catheter with electroanatomic mapping (EAM) guidance and also as a radiofrequency ablation (RFA) catheter. Preliminary thermal strain imaging (TSI)-derived temperature data were obtained from within the endocardium simultaneously during RFA to show the feasibility of direct ablation guidance procedures. Methods The new 9F forward-looking ICE catheter was constructed with 3 complementary technologies: a CMUT imaging array with a custom electronic array buffer, catheter surface electrodes for EAM guidance, and a special ablation tip, that permits simultaneous TSI and RFA. In vivo imaging studies of 5 anesthetized porcine models with 5 CMUT catheters were performed. Results The ML-CMUT ICE catheter provided high-resolution real-time wideband 2-dimensional (2D) images at greater than 8 MHz and is capable of both RFA and EAM guidance. Although the 24-element array aperture dimension is only 1.5 mm, the imaging depth of penetration is greater than 30 mm. The specially designed ultrasound-compatible metalized plastic tip allowed simultaneous imaging during ablation and direct acquisition of TSI data for tissue ablation temperatures. Postprocessing analysis showed a first-order correlation between TSI and temperature, permitting early development temperature-time relationships at specific myocardial ablation sites. Conclusions Multifunctional forward-looking ML-CMUT ICE catheters, with simultaneous intracardiac guidance, ultrasound imaging, and RFA, may offer a new means to improve interventional ablation procedures. PMID:22298868
Yousefshahi, Fardin; Azimpour, Khashayar; Boroumand, Mohammad Ali; Najafi, Mahdi; Barkhordari, Khosro; Vaezi, Mitra; Rouhipour, Nahid
2013-01-01
Background: Central venous (CV) catheters play an essential role in the management of critically ill patients in the Intensive Care Unit (ICU). CV lines are, however, allied to catheter-associated blood stream infections. Bacterial colonization of CV lines is deemed the main cause of catheter-associated infection. The purpose of our study was to compare bacterial colony counts in the catheter site before CV line insertion in two groups of post-cardiac surgery patients: a group receiving Sanosil (an antiseptic agent composed of H2O2 and silver) and a control group. Methods: This interventional prospective double-blinded clinical trial recruited the patients in three post-cardiac surgery ICUs of a heart center. The participants were divided into interventional (113 patients) and control (136 patients) groups. Sanosil was added to the routine preparation procedure (Chlorhexidine bath one day before and scrub with Povidone-Iodine just before the CV line insertion). After the removal of the CV lines, the catheters tips were sent for culture and evaluation of colony counts. Results: Catheter colonization occurred in 55 (22.1%) patients: 26 (23%) patients in the Sanosil group and 29 (21.3%) in the control group; there was no significant statistical difference between the two groups (p value = 0.75, RR = 1.05, 95% CI: 0.76–1.45). The most common organism having colonized in the cultures of the catheter tips was staphylococcus epidermis: 20 cases in the control group and 16 cases in the intervention group. Conclusion: Catheter colonization frequently occurs in post-cardiac surgery patients. However, our results did not indicate the effectiveness of adding Sanosil to the routine preparation procedure with respect to reducing catheter bacterial colonization. PMID:23967028
Yousefshahi, Fardin; Azimpour, Khashayar; Boroumand, Mohammad Ali; Najafi, Mahdi; Barkhordari, Khosro; Vaezi, Mitra; Rouhipour, Nahid
2013-04-01
Central venous (CV) catheters play an essential role in the management of critically ill patients in the Intensive Care Unit (ICU). CV lines are, however, allied to catheter-associated blood stream infections. Bacterial colonization of CV lines is deemed the main cause of catheter-associated infection. The purpose of our study was to compare bacterial colony counts in the catheter site before CV line insertion in two groups of post-cardiac surgery patients: a group receiving Sanosil (an antiseptic agent composed of H2O2 and silver) and a control group. This interventional prospective double-blinded clinical trial recruited the patients in three post-cardiac surgery ICUs of a heart center. The participants were divided into interventional (113 patients) and control (136 patients) groups. Sanosil was added to the routine preparation procedure (Chlorhexidine bath one day before and scrub with Povidone-Iodine just before the CV line insertion). After the removal of the CV lines, the catheters tips were sent for culture and evaluation of colony counts. Catheter colonization occurred in 55 (22.1%) patients: 26 (23%) patients in the Sanosil group and 29 (21.3%) in the control group; there was no significant statistical difference between the two groups (p value = 0.75, RR = 1.05, 95% CI: 0.76-1.45). The most common organism having colonized in the cultures of the catheter tips was staphylococcus epidermis: 20 cases in the control group and 16 cases in the intervention group. Catheter colonization frequently occurs in post-cardiac surgery patients. However, our results did not indicate the effectiveness of adding Sanosil to the routine preparation procedure with respect to reducing catheter bacterial colonization.
Okumura, Yasuo; Johnson, Susan B; Bunch, T Jared; Henz, Benhur D; O'Brien, Christine J; Packer, Douglas L
2008-06-01
While catheter tip/tissue contact has been shown to be an important determinant of ablative lesions in in vitro studies, the impact of contact on the outcomes of mapping and ablation in the intact heart has not been evaluated. Twelve dogs underwent atrial ablation guided by the Senesitrade mark robotic catheter remote control system. After intracardiac ultrasound (ICE) validation of contact force measured by an in-line mechanical sensor, the relationship between contact force and individual lesion formation was established during irrigated-tipped ablation (flow 17 mL/sec) at 15 watts for 30 seconds. Minimal contact by ICE correlated with force of 4.7 +/- 5.8 grams, consistent contact 9.9 +/- 8.6 grams and tissue tenting produced 25.0 +/- 14.0 grams. Conversely, catheter tip/tissue contact by ICE was predicted by contact force. A contact force of 10-20 and > or =20 grams generated full-thickness, larger volume ablative lesions than that created with <10 grams (98 +/- 69 and 89 +/- 70 mm(3) vs 40 +/- 42 mm(3), P < 0.05). Moderate (10 grams) and marked contact (15-20 grams) application produced 1.5 X greater electroanatomic map volumes that were seen with minimal contact (5 grams) (26 +/- 3 cm(3) vs 33 +/- 6, 39 +/- 3 cm(3), P < 0.05). The electroanatomic map/CT merge process was also more distorted when mapping was generated at moderate to marked contact force. This study shows that mapping and ablation using a robotic sheath guidance system are critically dependent on generated force. These findings suggest that ablative lesion size is optimized by the application of 10-20 grams of contact force, although mapping requires lower-force application to avoid image distortions.
2009-01-01
Introduction Spinal cord injury patients are at risk for developing unusual complications such as autonomic dysreflexia while changing suprapubic cystostomy. We report a male patient with spina bifida in whom the Foley catheter was placed in the urethra during change of suprapubic cystostomy with serious consequences. Case presentation A male patient, born in 1972 with spina bifida and paraplaegia, underwent suprapubic cystostomy in 2003 because of increasing problems with urethral catheter. The patient would come to spinal unit for change of suprapubic catheter every four to six weeks. Two days after a routine catheter change in November 2009, this patient woke up in the morning and noticed that the suprapubic catheter had come out. He went straight to Accident and Emergency. The suprapubic catheter was changed by a health professional and this patient was sent home. But the suprapubic catheter did not drain urine. This patient developed increasing degree of pain and swelling in suprapubic region. He did not pass any urine per urethra. He felt sick and came to spinal unit five hours later. About twenty ml of contrast was injected through suprapubic catheter and X-rays were taken. The suprapubic catheter was patent; the catheter was not blocked. The Foley catheter could be seen going around in a circular manner through the urinary bladder into the urethra. The contrast did not opacify urinary bladder; but proximal urethra was seen. The tip of Foley catheter was lying in proximal urethra. The balloon of Foley catheter had been inflated in urethra. When the balloon of Foley catheter was deflated, this patient developed massive bleeding per urethra. A sterile 22 French Foley catheter was inserted through suprapubic track. The catheter drained bloody urine. He was admitted to spinal unit and received intravenous fluids and meropenem. Haematuria subsided after 48 hours. The patient was discharged home a week later in a stable condition. Conclusion This case shows that serious complications can occur during change of suprapubic catheter in patients with neuropathic bladder. After inserting a new catheter, health professionals should observe spinal cord injury patients for at least thirty minutes and ensure that (1) suprapubic catheter drains clear urine; (2) patients do not develop abdominal spasm or discomfort; (3) symptoms and signs of sepsis or autonomic dysreflexia are absent. PMID:20062546
Vaidyanathan, Subramanian; Hughes, Peter L; Soni, Bakul M; Oo, Tun; Singh, Gurpreet
2009-12-22
Spinal cord injury patients are at risk for developing unusual complications such as autonomic dysreflexia while changing suprapubic cystostomy. We report a male patient with spina bifida in whom the Foley catheter was placed in the urethra during change of suprapubic cystostomy with serious consequences. A male patient, born in 1972 with spina bifida and paraplaegia, underwent suprapubic cystostomy in 2003 because of increasing problems with urethral catheter. The patient would come to spinal unit for change of suprapubic catheter every four to six weeks. Two days after a routine catheter change in November 2009, this patient woke up in the morning and noticed that the suprapubic catheter had come out. He went straight to Accident and Emergency. The suprapubic catheter was changed by a health professional and this patient was sent home. But the suprapubic catheter did not drain urine. This patient developed increasing degree of pain and swelling in suprapubic region. He did not pass any urine per urethra. He felt sick and came to spinal unit five hours later. About twenty ml of contrast was injected through suprapubic catheter and X-rays were taken. The suprapubic catheter was patent; the catheter was not blocked. The Foley catheter could be seen going around in a circular manner through the urinary bladder into the urethra. The contrast did not opacify urinary bladder; but proximal urethra was seen. The tip of Foley catheter was lying in proximal urethra. The balloon of Foley catheter had been inflated in urethra. When the balloon of Foley catheter was deflated, this patient developed massive bleeding per urethra. A sterile 22 French Foley catheter was inserted through suprapubic track. The catheter drained bloody urine. He was admitted to spinal unit and received intravenous fluids and meropenem. Haematuria subsided after 48 hours. The patient was discharged home a week later in a stable condition. This case shows that serious complications can occur during change of suprapubic catheter in patients with neuropathic bladder. After inserting a new catheter, health professionals should observe spinal cord injury patients for at least thirty minutes and ensure that (1) suprapubic catheter drains clear urine; (2) patients do not develop abdominal spasm or discomfort; (3) symptoms and signs of sepsis or autonomic dysreflexia are absent.
Poulin, Eric; Racine, Emmanuel; Binnekamp, Dirk; Beaulieu, Luc
2015-03-01
In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this technical note is to evaluate the accuracy and the robustness of an electromagnetic (EM) tracking system for automated and real-time catheter reconstruction. For this preclinical study, a total of ten catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a 18G biopsy needle, used as an EM stylet and equipped with a miniaturized sensor, and the second generation Aurora(®) Planar Field Generator from Northern Digital Inc. The Aurora EM system provides position and orientation value with precisions of 0.7 mm and 0.2°, respectively. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical computed tomography (CT) system with a spatial resolution of 89 μm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, five catheters were reconstructed twice and compared. Reconstruction time for one catheter was 10 s, leading to a total reconstruction time inferior to 3 min for a typical 17-catheter implant. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.66 ± 0.33 mm and 1.08 ± 0.72 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be more accurate. A maximum difference of less than 0.6 mm was found between successive EM reconstructions. The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poulin, Eric; Racine, Emmanuel; Beaulieu, Luc, E-mail: Luc.Beaulieu@phy.ulaval.ca
2015-03-15
Purpose: In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this technical note is to evaluate the accuracy and the robustness of an electromagnetic (EM) tracking system for automated and real-time catheter reconstruction. Methods: For this preclinical study, a total of ten catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a 18G biopsy needle, used as an EM stylet and equipped with a miniaturized sensor, and the second generation Aurora{sup ®} Planar Field Generator from Northern Digital Inc. The Aurora EM system provides position andmore » orientation value with precisions of 0.7 mm and 0.2°, respectively. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical computed tomography (CT) system with a spatial resolution of 89 μm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, five catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 s, leading to a total reconstruction time inferior to 3 min for a typical 17-catheter implant. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.66 ± 0.33 mm and 1.08 ± 0.72 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be more accurate. A maximum difference of less than 0.6 mm was found between successive EM reconstructions. Conclusions: The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators.« less
Arya, Arash; Zaker-Shahrak, Ruzbeh; Sommer, Phillip; Bollmann, Andreas; Wetzel, Ulrike; Gaspar, Thomas; Richter, Sergio; Husser, Daniela; Piorkowski, Christopher; Hindricks, Gerhard
2011-01-01
To compare the acute and the 6 month outcome of catheter ablation of atrial fibrillation (AF) using irrigated tip magnetic catheter and remote magnetic cathter navigation (RMN) with manual catheter navigation (MCN) in patients with paroxysmal and persistent AF. In this retrospective analysis 356 patients (235 male, mean age: 57.9 ± 10.9 years) with AF (70.5%, paroxysmal) who underwent catheter ablation between August 2007 and May 2008 using either RMN (n = 70, 46 male, mean age: 57.9 ± 10.1 years, 50% paroxysmal) or MCN (n = 286, 189 male, mean age: 58.0 ± 13.9 years, 75.5% paroxysmal) were included. All patients completed an intensive follow-up strategy. Complete pulmonary vein isolation was achieved in 87.6 and 99.6% of patients in RMN and MCN groups, respectively (P < 0.05). The procedure, fluoroscopy, and radiofrequency application times were 223 ± 44 vs. 166 ± 52 min (P < 0.0001), 13.7 ± 7.8 vs. 34.5 ± 15.1 min (P < 0.0001), and 75.4 ± 20.9 vs. 53.2 ± 21.4 min (P < 0.0001) in RMN and MCN groups, respectively. Seven (10.0%) and 28 (9.8%) patients in RMN and MCN groups received antiarrhythmic medications during the follow-up (P = 0.96). All the patients completed the 6 month follow-up. Freedom from AF at 6 months was achieved in 57.8 and 66.4% of the patients in RMN and MCN groups, respectively (P = 0.196). In patients without previous AF catheter ablation procedure the freedom from AF at 6 months were 68.2 and 60.5% in the MCN and RMN groups, respectively (P = 0.36). Catheter ablation using irrigated tip magnetic catheter and RMN is an effective and safe method for catheter ablation of AF. Compared to manual catheter navigation, the procedure and radiofrequency application times were longer and fluoroscopy time was shorter in the RMN group compared with the MCN group.
A Shape Memory Alloy-Based Miniaturized Actuator for Catheter Interventions.
Lu, Yueh-Hsun; Mani, Karthick; Panigrahi, Bivas; Hajari, Saurabh; Chen, Chia-Yuan
2018-06-26
In the current scenario of endovascular intervention, surgeons have to manually navigate the catheter within the complex vasculature of the human body under the guidance of X-ray. This manual intervention upsurges the possibilities of vessel damage due to frequent contact between the catheter and vasculature wall. In this context, a shape memory alloy-based miniaturized actuator was proposed in this study with a specific aim to reduce vessel wall related damage by improving the bending motions of the guidewire tip in a semi-automatic fashion. The miniaturized actuator was integrated with a FDA-approved guidewire and tested within a patient-specific vascular network model to realize its feasibility in the real surgical environment. The results illustrate that the miniaturized actuator gives a bending angle over 23° and lateral displacement over 900 µm to the guide wire tip by which the guidewire can be navigated with precision and possible vessel damage during the catheter intervention can certainly be minimized. In addition to it, the dynamic responses of the presented actuator were further investigated through numerical simulation in conjunction with the analytic analysis.
Kamoi, K; Teraski, T; Kojima, M; Uchida, M; Watanabe, H
1996-04-01
We developed a new technique to determine the laterality of microscopic hematuria by means of gas cystoscopy. An originally designed catheter system consisted of two catheters. On the tip of an inner catheter, a urine dipstick for blood was attached, with a cap on the tip of an outer catheter to keep the dipstick dry. In order to react a dipstick with the urine coming out from a ureteral orifice in the bladder, CO2 was insufflated into the bladder through a cystoscope (gas cystoscopy). The laterality of microscopic hematuria was determined in the bladder, based on the color reaction on the dipstick. This technique was performed successfully in 14 (88%) of 16 cases with microscopic hematuria. The laterality of microscopic hematuria was determined to be ipsilateral in 6 patients, which coincided with the side of a urological upper urinary tract disorder. In contract, bilateral microscopic hematuria was confirmed in 8 patients with glomerular disorders. The diagnostic process in patients with microscopic hematuria remains unsolved for urologists and nephrologists. This technique may provide a new approach in diagnosing microscopic hematuria.
Revel-Vilk, S; Yacobovich, J; Tamary, H; Goldstein, G; Nemet, S; Weintraub, M; Paltiel, O; Kenet, G
2010-09-01
The use of central venous catheters (CVCs) has greatly improved the quality of care in children with cancer, yet these catheters may cause serious infectious and thrombotic complications. The aim of this prospective registry study was to assess the host and CVC-related risk factors for CVC-created thrombotic complications. Patients undergoing CVC insertion for chemotherapy were followed prospectively for CVC complications. At the time of enrollment, demographic, clinical, and CVC-related data, and family history of thrombosis were collected. Survival and Cox regression analyses were performed. A total of 423 CVCs were inserted into 262 patients for a total of 76,540 catheter days. The incidence of CVC-related deep-vein thrombosis (DVT) was 0.13 per 1000 catheter-days (95% confidence interval [CI], 0.06-0.24). Insertion of peripherally inserted central catheters (PICCs) and insertion in an angiography suite significantly increased the risk of symptomatic CVC-related DVT. The incidence of CVC occlusion was 1.35 per 1000 catheter-days (95% CI, 1.1-1.63). Positive family history of thrombosis significantly increased the risk of CVC occlusion (hazard ratio [HR], 2.16; 95% CI, 1.2-3.8). The CVC-related risk factors were insertion of Hickman catheters, insertion in angiography suite, and proximal-tip location. Patients developing at least 1 episode of both CVC occlusion and infection had an increased risk for developing symptomatic CVC-related DVT (HR, 4.15; 95% CI, 1.2-14.4). Both patient-related and CVC-related factors are associated with higher risk of symptomatic thrombotic complications. These risk factors could be used in the clinical setting and in developing future studies for CVC thromboprophylaxis.
Shariat, M H; Gazor, S; Redfearn, D
2015-08-01
Atrial fibrillation (AF), the most common sustained cardiac arrhythmia, is an extremely costly public health problem. Catheter-based ablation is a common minimally invasive procedure to treat AF. Contemporary mapping methods are highly dependent on the accuracy of anatomic localization of rotor sources within the atria. In this paper, using simulated atrial intracardiac electrograms (IEGMs) during AF, we propose a computationally efficient method for localizing the tip of the electrical rotor with an Archimedean/arithmetic spiral wavefront. The proposed method deploys the locations of electrodes of a catheter and their IEGMs activation times to estimate the unknown parameters of the spiral wavefront including its tip location. The proposed method is able to localize the spiral as soon as the wave hits three electrodes of the catheter. Our simulation results show that the method can efficiently localize the spiral wavefront that rotates either clockwise or counterclockwise.
Atriocaval Rupture After Right Atrial Isthmus Ablation for Atrial Flutter.
Vloka, Caroline; Nelson, Daniel W; Wetherbee, Jule
2016-06-01
A patient with symptomatic typical atrial flutter (AFL) underwent right atrial isthmus ablation with an 8-mm catheter. Eight months later, his typical AFL recurred. Ten months later, he underwent a repeat right atrial isthmus ablation with an irrigated tip catheter and an 8-mm tip catheter. Six weeks after his second procedure, while performing intense sprint intervals on a treadmill, he developed an abrupt onset of chest pain, hypotension, and cardiac tamponade. He underwent emergency surgery to repair an atriocaval rupture and has done well since. Our report suggests that an association of multiple radiofrequency ablations with increased risk for delayed atriocaval rupture occurring 1 to 3 months after ablation. In conclusion, although patients generally were advised to limit exercise for 1 to 2 weeks after AFL ablation procedures in the past, it may be prudent to avoid intense exercise for at least 3 months after procedure. Copyright © 2016 Elsevier Inc. All rights reserved.
Miyazaki, Shinsuke; Shah, Ashok J; Xhaët, Olivier; Derval, Nicolas; Matsuo, Seiichiro; Wright, Matthew; Nault, Isabelle; Forclaz, Andrei; Jadidi, Amir S; Knecht, Sébastien; Rivard, Lena; Liu, Xingpeng; Linton, Nick; Sacher, Frédéric; Hocini, Mélèze; Jaïs, Pierre; Haïssaguerre, Michel
2010-12-01
The remote magnetic navigation system (MNS) has been used with a nonirrigated magnetic catheter for atrial fibrillation (AF) ablation. The objective of this study was to evaluate the feasibility and efficiency of the newly available irrigated tip magnetic catheter for index pulmonary vein isolation (PVI) in patients with paroxysmal AF (PAF). Between January 2008 and June 2009, 30 consecutive patients with drug-resistant PAF underwent circular mapping catheter-guided PVI with MNS (MNS group). The outcomes were compared retrospectively with those of a conventional hand-controlled ablation technique during the same period in 44 consecutive patients (manual group). All 4 pulmonary veins were successfully isolated in both groups except in 4 patients in the MNS group. Radiofrequency and procedure duration were higher in the MNS group (60 ± 27 versus 43 ± 16 minutes; P = 0.0019) than in the manual group (246 ± 50 versus 153 ± 51 minutes; P < 0.0001). In the patients who underwent only PVI, total fluoroscopic time also was longer in the MNS group than in the manual group (58 ± 24 versus 40 ± 14 minutes; P = 0.0002). At 12-month follow-up after a single procedure, 69.0% of the patients in MNS group and 61.8% of patients in manual group were free of atrial tachyarrhythmia without antiarrhythmic drugs. There was no significant difference in the atrial tachyarrhythmia-free survival between the 2 groups (P = 0.961). Cardiac tamponade occurred in 1 patient in the manual group. In patients with PAF, MNS-guided PVI with the newly available irrigated tip magnetic catheter backed up with manual ablation whenever required is feasible. However, it requires longer ablation, fluoroscopy, and procedural times than the conventional approach in the early experience stage.
Developing system for delivery of optical radiation in medicobiological researches
NASA Astrophysics Data System (ADS)
Loschenov, Victor B.; Taraz, Majid
2004-06-01
Methods of optical diagnostics and methods of photodynamic therapy are actively used in medico-biological researches. The system for delivery of optical radiation is one of the key methods in these researches. Usually these systems use flexible optical fibers with diameters from 200 to 1000 micron. Two types of systems for delivery are subdivided, first for diagnostic researches, second for therapeutic procedures. Existing diagnostic catheters, which have most widely applied in medicine, have bifurcated with diameter of the tip equal 1.8 mm. These devices, which are called fiber-optical catheters, satisfy the majority endoscopes researches. However, till now the problem of optical-diagnostics inside tissue is not soled. Especially it is important at diagnostics of a mammary gland, livers, thyroid glands tumor, tumor of a brain and some other studies connected with punctures. In these cases, it is necessary that diameter of fiber-optical catheters be less than one millimeter. This work is devoted to the development of these catheters. Also in clinical procedures such as photodynamic therapy (PDT) and interstitial laser photocoagulation (ILP), cylindrical light diffusing tips are rapidly becoming a popular device for the administration of the desired light dose for the illumination of hollow organs, such as bronchus, trachea and oesophagus. This work is devoted to the development of these catheters.
Arya, Arash; Kottkamp, Hans; Piorkowski, Christopher; Bollmann, Andreas; Gerdes-Li, Jin-Hong; Riahi, Sam; Esato, Masahiro; Hindricks, Gerhard
2008-05-01
A remote magnetic navigation system (MNS) is available and has been used with a 4-mm-tip magnetic catheter for radiofrequency (RF) ablation of some supraventricular and ventricular arrhythmias; however, it has not been evaluated for the ablation of cavotricuspid isthmus-dependent right atrial flutter (AFL). The present study evaluates the feasibility and efficiency of this system and the newly available 8-mm-tip magnetic catheter to perform RF ablation in patients with AFL. Twenty-six consecutive patients (23 men, mean age 64.6 +/- 9.6 years) underwent RF ablation using a remote MNS. RF ablation was performed with an 8-mm-tip magnetic catheter (70 degrees C, maximum power 70 W, 90 seconds). The endpoint of ablation was complete bidirectional isthmus block. To assess a possible learning curve, procedural data were compared between the first 14 (group 1) and the rest (group 2) of the patients. The initial rhythm during ablation was AFL in 20 (19 counterclockwise and 1 clockwise) and sinus rhythm in six patients. Due to technical issues, the ablation in the 18th patient could not be done with the MNS, and so we switched to conventional ablation. The remote magnetic navigation and ablation procedure was successful in 24 of the 25 (96%) remaining patients with AFL. In one patient (patient 2), conventional catheter was used to complete the isthmus block after termination of AFL. The procedure, preparation, ablation, and fluoroscopy times (median [range]) were 53 (30-130) minutes, 28 (10-65) minutes, 25 (12-78) minutes, and 7.5 (3.2-20.8) minutes, respectively. Patients in group 2 had shorter procedure (45 [30-70] min vs 80 [57-130] min, P = 0.0001), preparation (25 [10-30] min vs 42 [30-65] min, P = 0.0001), ablation (20 [12-40] min vs 31 [20-78] min, P = 0.002), and fluoroscopy (7.2 [3.2-12.2] min vs 11.0 [5.4-20.8] min, P = 0.014) times. No complication occurred during the procedure. Using a remote MNS and an 8-mm-tip magnetic catheter, ablation of AFL is feasible, safe, and effective. Our data suggest that there is a short learning curve for this procedure.
Bourier, Felix; Hessling, Gabriele; Ammar-Busch, Sonia; Kottmaier, Marc; Buiatti, Alessandra; Grebmer, Christian; Telishevska, Marta; Semmler, Verena; Lennerz, Carsten; Schneider, Christine; Kolb, Christof; Deisenhofer, Isabel; Reents, Tilko
2016-03-01
Contact-force (CF) sensing catheters are increasingly used in clinical electrophysiological practice due to their efficacy and safety profile. As data about the accuracy of this technology are scarce, we sought to quantify accuracy based on in vitro experiments. A custom-made force sensor was constructed that allowed exact force reference measurements registered via a flexible membrane. A Smarttouch Surround Flow (ST SF) ablation catheter (Biosense Webster, Diamond Bar, CA, USA) was brought in contact with the membrane of the force sensor in order to compare the ST SF force measurements to force sensor reference measurements. ST SF force sensing technology is based on deflection registration between the distal and proximal catheter tip. The experiment was repeated for n = 10 ST SF catheters, which showed no significant difference in accuracy levels. A series of measurements (n = 1200) was carried out for different angles of force acting to the catheter tip (0°/perpendicular contact, 30°, 60°, 90°/parallel contact). The mean absolute differences between reference and ST SF measurements were 1.7 ± 1.8 g (0°), 1.6 ± 1.2 g (30°), 1.4 ± 1.3 g (60°), and 6.6 ± 5.9 g (90°). Measurement accuracy was significantly higher in non-parallel contact when compared with parallel contact (P < 0.01). Catheter force measurements using the ST SF catheters show a high level of accuracy regarding differences to reference measurements and reproducibility. The reduced accuracy in measurements of 90° acting forces (parallel contact) might be clinically important when creating, for example, linear lesions. © 2015 Wiley Periodicals, Inc.
Catheter orifice configuration influences the effectiveness of continuous peripheral nerve blockade.
Fredrickson, Michael J; Ball, Craig M; Dalgleish, Adam J
2011-01-01
We investigated perineural catheter threading distance and orifice configuration during continuous interscalene analgesia. One hundred fifty-three patients receiving an anterolateral interscalene catheter (catheter needle and nerve/plexus in a similar alignment) for elective shoulder surgery were randomized to 1 of 3 groups: following out-of-plane ultrasound confirmation of the needle tip immediately lateral to the C5/6 roots, a nonstimulating catheter was blindly advanced 0.5 cm (end-hole; n = 50), 2.5 cm (multiorifice; n = 50) or 5 cm (multiorifice; n = 53) beyond the needle tip. Ropivacaine 0.75% + lidocaine 1% (50:50) 20 mL was administered preoperatively via the catheter before surgery under general anesthesia. A ropivacaine 0.2% 2 mL/hr elastomeric infusion with mandatory 6 hourly (and on demand) 5-mL boluses was continued for more than 48 hrs with tramadol available as rescue. Patients were questioned in the recovery room, at 24 and 48 hrs for numerical rating pain score (0-10), ropivacaine bolus, and tramadol consumption. Patients were more frequently pain-free in the recovery room in the multiorifice 2.5 and 5 cm groups compared with the end-hole 0.5 cm group (94%, 91% vs 66%; P < 0.001). During the first 24 hrs, the end-hole group demonstrated an earlier time to first pain (median, 10 vs17, 15 hrs; P < 0.001), higher "average pain" (median, 3 vs 1, 2, P = 0.004), and more ropivacaine bolus (median, 5 vs 3, 3; P < 0.001) and tramadol consumption (P = 0.01). Groups 2.5 and 5 cm did not significantly differ in any outcomes. These results suggest that multiorifice catheters provide superior intermittent bolus continuous peripheral nerve blockade compared with end-hole catheters. For anterolateral approach interscalene catheter placement, there is minimal benefit, either way, to 2.5- or 5-cm blind catheter advancement.
Tietz, Andreas; Frei, Reno; Dangel, Marc; Bolliger, Dora; Passweg, Jakob R; Gratwohl, Alois; Widmer, Andreas E
2005-08-01
To determine the efficacy and tolerability of octenidine hydrochloride, a non-alcoholic skin antiseptic, for the care of central venous catheter (CVC) insertion sites. Prospective, observational study. Bone marrow transplantation unit of a university hospital. All consecutive patients with a nontunneled CVC were enrolled prospectively after informed consent. Octenidine hydrochloride (0.1%) was applied for disinfection at the CVC insertion site during dressing changes. The following cultures were performed weekly as well as at the occurrence of any systemic inflammatory response syndrome criteria: cultures of the skin surrounding the CVC entry site, cultures of the three-way hub connected to the CVC, blood cultures, and cultures of the CVC tip on removal. Enhanced microbiological methods (skin swabs of a 24-cm2 standardized area, roll plate, and sonication of catheter tips) were applied. One hundred thirty-five CVCs were inserted in 62 patients during the study period and remained for a mean period of 19.1 days, corresponding to 2,462 catheter-days. Bacterial density at the insertion site declined substantially over time, and most cultures became negative 2 weeks after insertion. Only 6 patients had a documented catheter-related bloodstream infection. The incidence density was 2.39 catheter infections per 1,000 catheter-days. No side effects were noted with application of the antiseptic. Disinfection with a skin antiseptic that contains octenidine hydrochloride is highly active and well tolerated. It leads to a decrease in skin colonization over time and may be a new option for CVC care.
Soleimani, Sajjad; Dubini, Gabriele; Pennati, Giancarlo
2014-10-01
According to a number of clinical studies, coronary aspiration catheters are useful tools to remove a thrombus (blood clot) blocking a coronary artery. However, these thrombectomy devices may fail to remove the blood clot entirely. Few studies have been devoted to a systematic analysis of factors affecting clot aspiration. The geometric characteristics of the aspiration catheter, the physical properties of the thrombus, and the applied vacuum pressure are crucial parameters. In this study, the aspiration of a blood clot blocking a coronary bifurcation is computationally simulated. The clot is modeled as a highly viscous fluid, and a two-phase (blood and clot) problem is solved. The effects of geometric variations in the tip of the coronary catheter, including lateral hole size and location, are investigated considering different aspiration pressures and clot viscosities. A Bird-Carreau model is adopted for blood viscosity, while a power law model is used to describe the clot rheology. Computational results for blood clot aspiration show that the presence of holes in the lateral part of the tip of the catheter can be beneficial depending on clot viscosity, hole features, and applied aspiration pressure. In general, the holes are beneficial when the clot viscosity is low, while aspiration catheters without any extra lateral holes exhibit better performance for higher clot viscosity. However, when higher aspiration pressures are applied, the catheters tend to behave relatively similarly in removing clots with various viscosities, reducing the role of the clot viscosity. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Schricker, Amir A; Feld, Gregory K; Tsimikas, Sotirios
2015-11-15
Transseptal introducer sheaths are being used with increasing frequency for left-sided arrhythmia ablations and structural heart disease interventions. Sheath tip detachment and embolization is an uncommon but known complication, and several sheaths have been recalled due to such complications. We report a unique case of a fractured transseptal sheath tip that embolized to a branch of the right pulmonary artery in a patient who had undergone ablation of a left-sided atypical atrial flutter. During final removal of one of the two long 8.5-French SL1 transseptal sheaths used routinely as part of the ablation, the radiopaque tip of the sheath fractured and first embolized to the right atrium and subsequently to a secondary right pulmonary artery branch. Using techniques derived from percutaneous interventional approaches, including a multipurpose catheter, coronary guidewire, and monorail angioplasty balloon, the sheath tip was successfully wired through its inner lumen, trapped from the inside with the balloon, and removed from the body via a large femoral vein sheath, without complications. The approach detailed in this case may guide future cases and circumvent urgent surgical intervention. © 2015 Wiley Periodicals, Inc.
[Rotational stability of angiography catheters].
Schröder, J; Weber, M
1992-10-01
Rotatory stability is a parameter that reflects the ability of a catheter to transmit a rotation applied at the outer end to the catheter tip for the purpose of selective probing. A method for measuring the rotatory stability is described, and the results of rotatory stability measurements of 70 different commercially available catheters are reported. There is an almost linear correlation between the rotatory stability and the difference between the respective fourth power of the external and internal diameter or, approximately, to the fourth power of the external diameter for catheters without wire reinforcement. With the same cross-sectional dimensions, the rotatory stability of teflon, polyethylene, and nylon catheters has an approximate ratio of 1:2:4. Wire reinforcement increases rotatory stability by an average factor of about 3. For catheters of calibers 5 F and 6 F, a correlation between the rotatory stability and the weight of the reinforcing wire mesh is apparent.
Vaidyanathan, Subramanian; Soni, Bakul M; Oo, Tun; Hughes, Peter L; Singh, Gurpreet
2014-01-01
Autonomic dysreflexia is poorly recognised outside of spinal cord injury centres, and may result in adverse outcomes including mortality from delayed diagnosis and treatment. We present a spinal cord injury patient, who developed autonomic dysreflexia following incorrect placement of urethral Foley catheter. Health professionals failed to recognise signs and symptoms of autonomic dysreflexia as well as its significance in this tetraplegic patient. A tetraplegic patient started sweating profusely following insertion of a Foley catheter per urethra. The catheter was draining urine; there was no bypassing, no bleeding per urethra, and no haematuria. Patient's wife, who had been looking after her tetraplegic husband for more than forty years, told the health professionals that the catheter might have been placed incorrectly but her concerns were ignored. Ultrasound scan of urinary tract revealed no urinary calculi, no hydronephrosis. The balloon of Foley catheter was not seen in urinary bladder but this finding was not recognised by radiologist and spinal cord physician. Patient continued to sweat profusely; therefore, CT of pelvis was performed, but there was a delay of ten days. CT revealed the balloon of Foley catheter in the over-stretched prostate-membranous urethra; the tip of catheter was not located within the urinary bladder but was lying distal to bladder neck. Flexible cystoscopy was performed and Foley catheter was inserted into the bladder over a guide wire. The intensity of sweating decreased; noxious stimuli arising from traumatised urethra might take a long while to settle. Inserting a catheter in a tetraplegic patient should be carried out by a senior health professional, who is familiar with spasm of bladder neck which occurs frequently in tetraplegic patients. Facilities for urgent CT scan should be available to check the position of Foley catheter in spinal cord injury patients when a patient manifests signs and symptoms of autonomic dysreflexia following insertion of a urethral catheter. When an isolated symptom such as flushing or sweating is noticed in a tetraplegic patient, doctors should seek out other signs/symptoms of autonomic dysreflexia.
Campbell-Washburn, Adrienne E; Rogers, Toby; Stine, Annette M; Khan, Jaffar M; Ramasawmy, Rajiv; Schenke, William H; McGuirt, Delaney R; Mazal, Jonathan R; Grant, Laurie P; Grant, Elena K; Herzka, Daniel A; Lederman, Robert J
2018-06-21
Cardiovascular magnetic resonance (CMR) fluoroscopy allows for simultaneous measurement of cardiac function, flow and chamber pressure during diagnostic heart catheterization. To date, commercial metallic guidewires were considered contraindicated during CMR fluoroscopy due to concerns over radiofrequency (RF)-induced heating. The inability to use metallic guidewires hampers catheter navigation in patients with challenging anatomy. Here we use low specific absorption rate (SAR) imaging from gradient echo spiral acquisitions and a commercial nitinol guidewire for CMR fluoroscopy right heart catheterization in patients. The low-SAR imaging protocol used a reduced flip angle gradient echo acquisition (10° vs 45°) and a longer repetition time (TR) spiral readout (10 ms vs 2.98 ms). Temperature was measured in vitro in the ASTM 2182 gel phantom and post-mortem animal experiments to ensure freedom from heating with the selected guidewire (150 cm × 0.035″ angled-tip nitinol Terumo Glidewire). Seven patients underwent CMR fluoroscopy catheterization. Time to enter each chamber (superior vena cava, main pulmonary artery, and each branch pulmonary artery) was recorded and device visibility and confidence in catheter and guidewire position were scored on a Likert-type scale. Negligible heating (< 0.07°C) was observed under all in vitro conditions using this guidewire and imaging approach. In patients, chamber entry was successful in 100% of attempts with a guidewire compared to 94% without a guidewire, with failures to reach the branch pulmonary arteries. Time-to-enter each chamber was similar (p=NS) for the two approaches. The guidewire imparted useful catheter shaft conspicuity and enabled interactive modification of catheter shaft stiffness, however, the guidewire tip visibility was poor. Under specific conditions, trained operators can apply low-SAR imaging and using a specific fully-insulated metallic nitinol guidewire (150 cm × 0.035" Terumo Glidewire) to augment clinical CMR fluoroscopy right heart catheterization. Clinicaltrials.gov NCT03152773 , registered May 15, 2017.
Acute Urinary Obstruction in a Tetraplegic Patient from Misplacement of Catheter in Urethra.
Vaidyanathan, Subramanian; Singh, Gurpreet; Hughes, Peter L; Soni, Bakul M
2016-01-01
A male tetraplegic patient attended accident and emergency with a blocked catheter; on removing the catheter, he passed bloody urine. After three unsuccessful attempts were made to insert a catheter by nursing staff, a junior doctor inserted a three-way Foley catheter with a 30-mL balloon but inflated the balloon with 10 mL of water to commence the bladder irrigation. The creatinine level was mostly 19 µmol/L (range: 0-135 µmol/L) but increased to 46 µmol/L on day 7. Computerized tomography urogram revealed that the bilateral hydronephrosis with hydroureter was extended down to urinary bladder, the bladder was distended, prostatic urethra was dilated and filled with urine, and although the balloon of Foley catheter was not seen in the bladder, the tip of the catheter was seen lying in the urethra. Following the re-catheterization, the creatinine level decreased to 21 µmol/L. A follow-up ultrasound scan revealed no evidence of hydronephrosis in both kidneys. Flexible cystoscopy revealed inflamed bladder mucosa, catheter reaction, and tiny stones. There was no bladder tumor. This case report concludes that the cause of bilateral hydronephrosis, hydroureter, and distended bladder was inadequate drainage of urinary bladder as the Foley balloon that was under-filled slipped into the urethra resulting in an obstruction to urine flow. Urethral catheterization in tetraplegic patients should be performed by senior, experienced staff in order to avoid trauma and incorrect positioning. Tetraplegic subjects with decreased muscle mass have low creatinine level. Increase in creatinine level (>1.5 times the basal level) indicates acute kidney injury, although peak creatinine level may still be within laboratory reference range. While scanning the urinary tract of spinal cord injury patients with indwelling urinary catheter, if Foley balloon is not seen within the bladder, urethra should be scanned to locate the Foley balloon.
Jean, G; Vanel, T; Chazot, C; Charra, B; Terrat, J C; Hurot, J M
2001-01-01
Central venous stenosis (ST) and thrombosis (TB) related to catheter (KT) had been reported mostly for the subclavian vein. We performed a systematic cavographic study to evaluate the prevalence of these complications in 51 hemodialysis patients with present or previous history of tunneled internal jugular catheter. Each of them had used one or several KT (1.8 +/- 1.4 KT) for a mean 28 +/- 26 month cumulative time (i.e. 43,584 days total exposure time). Fifty percent of the KT were PermCath Quinton and 50% were Twincath (uncuffed) or CS 100 (cuffed) Medcomp. Twenty-seven had no ST (53%, group I), 24 had one or several significant ST (47%, group II) of superior Vena Cava (SVC, n = 4), inferior Vena Cava (IVC, n = 1), Brachio-cephalic Vein (BCV, n = 5) and subclavian vein (SC, n = 10), or a TB of SVC (n = 1), IVC (n = 3), BCV (n = 3), SC (n = 2). This accounts for an incidence of 0.55 ST or TB/1000 patient-days. Five of the twelve subclavian ST and TB had no history of previous subclavian catheter. Comparison between the two groups showed no differences according to age, time on dialysis, diabetes, hematocrit, CRP, cumulative time with catheter, catheter-related infections, type of catheter and anticoagulant treatment. IVC catheter tip's position is an important risk factor for TB and ST (4/6). Twelve group II patients had ST or TB-related symptoms, with a functional AV fistula in 9 cases. Eleven patients underwent repeated percutaneous angioplasty with 4 additional Wallstents and in 2 cases an AV fistula need to be closed. Central venous ST and TB after a jugular KT is extremely frequent, mostly without any symptoms. Consequences on peripheral or central vascular access, cost and poor long-term patency rate of angioplasty are of major importance. These results incite us to further reduce the catheter use in dialysis patients.
Tewari, Sanjit O; Getrajdman, George I; Petre, Elena N; Sofocleous, Constantinos T; Siegelbaum, Robert H; Erinjeri, Joseph P; Weiser, Martin R; Thornton, Raymond H
2015-02-01
To assess the safety and efficacy of image-guided percutaneous cecostomy/colostomy (PC) in the management of colonic obstruction in patients with cancer. Twenty-seven consecutive patients underwent image-guided PC to relieve large bowel obstruction at a single institution between 2000 and 2012. Colonic obstruction was the common indication. Patient demographics, diagnosis, procedural details, and outcomes including maximum colonic distension (MCD; ie, greatest transverse measurement of the colon on radiograph or scout computed tomography image) were recorded and retrospectively analyzed. Following PC, no patient experienced colonic perforation; pain was relieved in 24 of 27 patients (89%). Catheters with tip position in luminal gas rather than mixed stool/gas or stool were associated with greater decrease in MCD (-40%, -12%, and -16%, respectively), with the difference reaching statistical significance (P = .002 and P = .013, respectively). Catheter size was not associated with change in MCD (P = .978). Catheters were successfully removed from six of nine patients (67%) with functional obstructions and two of 18 patients (11%) with mechanical obstructions. One patient underwent endoscopic stent placement after catheter removal. Three patients required diverting colostomy after PC, and their catheters were removed at the time of surgery. One major complication (3.7%; subcutaneous emphysema, pneumomediastinum, and sepsis) occurred 8 days after PC and was successfully treated with cecostomy exchange, soft-tissue drainage, and intravenous antibiotic therapy. Image-guided PC is safe and effective for management of functional and mechanical bowel obstruction in patients with cancer. For optimal efficacy, catheters should terminate within luminal gas. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.
Intrathecal Baclofen Therapy in a Child With Severe Scoliosis: Report of 2 Cases.
Sasaki, Natsu; Ogiwara, Hideki
2016-08-01
Scoliosis is commonly found in children with cerebral palsy. Many patients with cerebral palsy and scoliosis undergo intrathecal baclofen (ITB) pump placement. The authors report 2 cases with cerebral palsy and severe scoliosis treated with intrathecal baclofen. The case of a 7-year-old boy with shunted hydrocephalus required surgical revision of the intrathecal catheter, while the other patient without shunt did not require revision. In the patient with shunted hydrocephalus, after the initial placement of baclofen pump and catheter at Th3 level, spasticity of lower extremities did not improve. The Indium(111) diethylenetriamine pentaacetic acid (In(111) DTPA) scintigraphy with injection of In(111) DTPA through the pump did not demonstrate distribution of the tracer to the lumbosacral area. Conversely, by direct injection of In(111) DTPA through lumbar puncture, the tracer distributed in the whole spinal canal. Replacement of the tip of the catheter caudal to the curve of the scoliosis improved the symptom. The authors suggest that, in patients with severe scoliosis and shunted hydrocephalus, it may be necessary to place the tip of the catheter caudal to the curve of the scoliosis for correction of spasticity of lower extremities. © 2016 International Neuromodulation Society.
A deflectable guiding catheter for real-time MRI-guided interventions.
Bell, Jamie A; Saikus, Christina E; Ratnayaka, Kanishka; Wu, Vincent; Sonmez, Merdim; Faranesh, Anthony Z; Colyer, Jessica H; Lederman, Robert J; Kocaturk, Ozgur
2012-04-01
To design a deflectable guiding catheter that omits long metallic components yet preserves mechanical properties to facilitate therapeutic interventional MRI procedures. The catheter shaft incorporated Kevlar braiding. A 180° deflection was attained with a 5-cm nitinol slotted tube, a nitinol spring, and a Kevlar pull string. We tested three designs: passive, passive incorporating an inductively coupled coil, and active receiver. We characterized mechanical properties, MRI properties, RF induced heating, and in vivo performance in swine. Torque and tip deflection force were satisfactory. Representative procedures included hepatic and azygos vein access, laser cardiac septostomy, and atrial septal defect crossing. Visualization was best in the active configuration, delineating profile and tip orientation. The passive configuration could be used in tandem with an active guidewire to overcome its limited conspicuity. There was no RF-induced heating in all configurations under expected use conditions in vitro and in vivo. Kevlar and short nitinol component substitutions preserved mechanical properties. The active design offered the best visibility and usability but reintroduced metal conductors. We describe versatile deflectable guiding catheters with a 0.057" lumen for interventional MRI catheterization. Implementations are feasible using active, inductive, and passive visualization strategies to suit application requirements. Copyright © 2011 Wiley Periodicals, Inc.
Huo, Yan; Hindricks, Gerhard; Piorkowski, Christopher; Bollmann, Andreas; Wetzel, Ulrike; Sommer, Phillip; Gaspar, Thomas; Kottkamp, Hans; Arya, Arash
2010-06-01
The objective of this study was to compare results between the magnetic navigation system (MNS) and conventional catheter ablation of cavo-tricuspid isthmus (CTI)-dependent right atrial flutter (AFL) in a case control study. A remote MNS has been used for ablation of various arrhythmias including CTI-dependent AFL but comparative results between MNS and conventional ablation are not available. Between May and September 2007, a total of 51 consecutive patients (45 men, mean age 65.4 +/- 9.4 years) had undergone catheter ablation for CTI-dependent AFL. The catheter ablation (70 degrees C, 70 W, 90 s) was performed with either an 8-mm-tip magnetic catheter using MNS (case group, n = 26, 23 men, mean age 64.6 +/- 9.6 y) or a conventional 8-mm catheter (case group, n = 25, 22 men, mean age 65.4 +/- 9.1 y). Acute procedural success was defined as complete bidirectional isthmus block and success at six months was defined as absence of AFL during the six months follow-up. With respect to baseline characteristics there were no differences between the two groups. The procedure time in MNS and conventional group was [median (range)] 53 (30-130) min and 45 (30-100) min, respectively (P = 0.12). Acute success was achieved by MNS and conventional ablation in 25/26 (96.2%) and 25/25 (100%) of patients, respectively (P = 0.53). During the six months of follow-up 4 patients, 2 in each group, experienced recurrence (P = 0.90). No major complication occurred during the procedure. Charring on the catheter tip occurred in 5 patients (19.2%) in MNS and none of the patients in the control group (P <0.05). This case-control study demonstrated the acute and mid-term efficacy and safety of catheter ablation by MNS for CTI-dependent AFL, similar to rates achieved by conventional radiofrequency catheter ablation.
Patel, Mehul B; Worley, Seth J
2013-04-01
Limitations imposed by the coronary sinus venous anatomy triggered the transseptal approach for endocardial LV lead placement. The alignment of the interatrial septum (IAS) and its neighborhood anatomy does not favor transseptal puncture from the pre-pectoral area. Locating and advancing a pre-pectoral LV lead delivery catheter (PDC) through an opening created in the IAS via femoral transseptal puncture (FTP) is time consuming and technically difficult. We describe a method where the PDC is snare coupled to the femoral transseptal apparatus (FTA). When the FTA is advanced into the left atrium (LA) the coupled PDC follows. The catheter of a 25-mm loop snare kit is replaced with the PDC (SelectSite®). The snare loop is positioned in the right common iliac vein from the pre-pectoral access. The PDC is coupled to the FTA by advancing the transseptal apparatus through the open snare loop. After conventional FTP, the FTA is withdrawn back into the right atrium (RA) over an extra support wire positioned in the LA. The PDC with open snare loop is pulled over the FTA up to the RA. The PDC is advanced to close the snare loop on the extra support wire immediately distal to the tip of the dilator close to the puncture site. The PDC is deflected to align with the FTA. The snare coupled catheters are gently advanced across the IAS into the LA. The PDC is released from the FTA by advancing the snare and opening the loop; the snare is then removed from the PDC. The PDC is deflected and advanced into the left ventricle (LV). After positioning the 4.1 Fr lumen less LV lead, the PDC is sliced and removed. The PDC snare coupled to the FTA was advanced into the LA in all five patients, however, access was lost during catheter manipulation in the one right-sided case. Endocardial LV lead was successfully positioned in all five patients. Snare coupling the pre-pectoral SelectSite® catheter to the FTA is technically simple, reliable and a safe method for transseptal endocardial LV lead placement for left pre-pectoral implantation.
Detecting thermal discrepancies in vessel walls
NASA Technical Reports Server (NTRS)
Casscells, S. Ward (Inventor); Willerson, James T. (Inventor); Eastwood, Michael L. (Inventor); Bearman, Gregory H. (Inventor); Krabach, Timothy N. (Inventor)
1999-01-01
An infrared, heat-sensing catheter particularly useful for identifying potentially fatal arterial plaques in patients with disease of the coronary or other arteries and its use are detailed. In one embodiment, an infrared fiberoptic system (with or without ultrasound) is employed at the tip of the catheter to locate inflamed, heat-producing, atherosclerotic plaque, which is at greater risk for rupture, fissure, or ulceration, and consequent thrombosis and occlusion of the artery. In another embodiment, a catheter with an infrared detector (with or without ultrasound) employed at its tip will likewise locate inflamed heat-producing atherosclerotic plaque. The devices and methods of the invention may be used to detect abscesses, infection, and cancerous regions by the heat such regions differentially display over the ambient temperature of immediately adjacent tissues. The methods and devices of the invention may also be used to detect regions of cooler than ambient tissue in a vessel or organ which indicate cell death, thrombosis, cell death, hemorrhage, calcium or cholesterol accumulations, or foreign materials.
Kocaturk, Ozgur; Saikus, Christina E; Guttman, Michael A; Faranesh, Anthony Z; Ratnayaka, Kanishka; Ozturk, Cengizhan; McVeigh, Elliot R; Lederman, Robert J
2009-08-12
Catheter visualization and tracking remains a challenge in interventional MR.Active guidewires can be made conspicuous in "profile" along their whole shaft exploiting metallic core wire and hypotube components that are intrinsic to their mechanical performance. Polymer-based catheters, on the other hand, offer no conductive medium to carry radio frequency waves. We developed a new "active" catheter design for interventional MR with mechanical performance resembling braided X-ray devices. Our 75 cm long hybrid catheter shaft incorporates a wire lattice in a polymer matrix, and contains three distal loop coils in a flexible and torquable 7Fr device. We explored the impact of braid material designs on radiofrequency and mechanical performance. The incorporation of copper wire into in a superelastic nitinol braided loopless antenna allowed good visualization of the whole shaft (70 cm) in vitro and in vivo in swine during real-time MR with 1.5 T scanner. Additional distal tip coils enhanced tip visibility. Increasing the copper:nitinol ratio in braiding configurations improved flexibility at the expense of torquability. We found a 16-wire braid of 1:1 copper:nitinol to have the optimum balance of mechanical (trackability, flexibility, torquability) and antenna (signal attenuation) properties. With this configuration, the temperature increase remained less than 2 degrees C during real-time MR within 10 cm horizontal from the isocenter. The design was conspicuous in vitro and in vivo. We have engineered a new loopless antenna configuration that imparts interventional MR catheters with satisfactory mechanical and imaging characteristics. This compact loopless antenna design can be generalized to visualize the whole shaft of any general-purpose polymer catheter to perform safe interventional procedures.
Kocaturk, Ozgur; Saikus, Christina E; Guttman, Michael A; Faranesh, Anthony Z; Ratnayaka, Kanishka; Ozturk, Cengizhan; McVeigh, Elliot R; Lederman, Robert J
2009-01-01
Background Catheter visualization and tracking remains a challenge in interventional MR. Active guidewires can be made conspicuous in "profile" along their whole shaft exploiting metallic core wire and hypotube components that are intrinsic to their mechanical performance. Polymer-based catheters, on the other hand, offer no conductive medium to carry radio frequency waves. We developed a new "active" catheter design for interventional MR with mechanical performance resembling braided X-ray devices. Our 75 cm long hybrid catheter shaft incorporates a wire lattice in a polymer matrix, and contains three distal loop coils in a flexible and torquable 7Fr device. We explored the impact of braid material designs on radiofrequency and mechanical performance. Results The incorporation of copper wire into in a superelastic nitinol braided loopless antenna allowed good visualization of the whole shaft (70 cm) in vitro and in vivo in swine during real-time MR with 1.5 T scanner. Additional distal tip coils enhanced tip visibility. Increasing the copper:nitinol ratio in braiding configurations improved flexibility at the expense of torquability. We found a 16-wire braid of 1:1 copper:nitinol to have the optimum balance of mechanical (trackability, flexibility, torquability) and antenna (signal attenuation) properties. With this configuration, the temperature increase remained less than 2°C during real-time MR within 10 cm horizontal from the isocenter. The design was conspicuous in vitro and in vivo. Conclusion We have engineered a new loopless antenna configuration that imparts interventional MR catheters with satisfactory mechanical and imaging characteristics. This compact loopless antenna design can be generalized to visualize the whole shaft of any general-purpose polymer catheter to perform safe interventional procedures. PMID:19674464
NASA Astrophysics Data System (ADS)
Sillay, Karl; Schomberg, Dominic; Hinchman, Angelica; Kumbier, Lauren; Ross, Chris; Kubota, Ken; Brodsky, Ethan; Miranpuri, Gurwattan
2012-04-01
Convection-enhanced delivery (CED) is an advanced infusion technique used to deliver therapeutic agents into the brain. CED has shown promise in recent clinical trials. Independent verification of published parameters is warranted with benchmark testing of published parameters in applicable models such as gel phantoms, ex vivo tissue and in vivo non-human animal models to effectively inform planned and future clinical therapies. In the current study, specific performance characteristics of two CED infusion catheter systems, such as backflow, infusion cloud morphology, volume of distribution (mm3) versus the infused volume (mm3) (Vd/Vi) ratios, rate of infusion (µl min-1) and pressure (mmHg), were examined to ensure published performance standards for the ERG valve-tip (VT) catheter. We tested the hypothesis that the ERG VT catheter with an infusion protocol of a steady 1 µl min-1 functionality is comparable to the newly FDA approved MRI Interventions Smart Flow (SF) catheter with the UCSF infusion protocol in an agarose gel model. In the gel phantom models, no significant difference was found in performance parameters between the VT and SF catheter. We report, for the first time, such benchmark characteristics in CED between these two otherwise similar single-end port VT with stylet and end-port non-stylet infusion systems. Results of the current study in agarose gel models suggest that the performance of the VT catheter is comparable to the SF catheter and warrants further investigation as a tool in the armamentarium of CED techniques for eventual clinical use and application.
A New CT-Guided Modified Trocar Technique for Drainage of Difficult Locations Abscesses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tyng, Chiang J., E-mail: chiangjengtyng@gmail.com; Amoedo, Maurício K.; Bohrer, Yves
PurposeComputed tomography (CT) is commonly used to guide drainage of deep-seated abdominal fluid collections. However, in some cases, these collections seem to be inaccessible due to surrounding organs or their being in difficult locations. The aim of this study is to describe a modified Trocar technique to drain collections in difficult locations, especially those in the subphrenic space, without passing through intervening organs.Materials and MethodsThis retrospective case series study describes seven inpatients who underwent CT-guided drainage using a modified Trocar technique for abscesses that are difficult to access percutaneously. All patients provided written informed consent prior to the procedure. Aftermore » placement of a 12–14F catheter inside the peritoneum, the Trocar stylet was removed so that the tip of the catheter became blunt and flexible to avoid injury to organs and structures in the catheter route, and the catheter was slowly advanced towards the collection using CT guidance and tactile sensation. After reaching the target, the stylet was reintroduced to enter the abscess wall.ResultsAll procedures were performed using an anterior abdominal wall access with adequate catheter positioning and resulted in clinical status improvement in the days after the drainage. No complications related to the procedure were identified in any of the patients.ConclusionsThe modified Trocar technique for percutaneous CT-guided drainage of abdominal abscesses may be feasible for lesions that are difficult to access with conventional methods.« less
Accuracy of external ventricular drainage catheter placement.
Abdoh, Mohammad Ghazi; Bekaert, Olivier; Hodel, Jérôme; Diarra, Salia Mamadou; Le Guerinel, Caroline; Nseir, Rémi; Bastuji-Garin, Sylvie; Decq, Philippe
2012-01-01
External ventricular drainage (EVD) is a freehand neurosurgical procedure performed routinely using the anatomical landmarks. The aim of this study was to determine the accuracy of EVD catheter freehand placement. Pre-operative and post-operative computed tomography scans for 66 consecutive EVDs performed in 56 adult patients (26 men, 30 women) in 2008 were retrospectively reviewed. Etiologies of acute hydrocephalus were subarachnoid or intraventricular haemorrhage (43 cases) or miscellaneous (13 cases). Pre-operative lateral ventricular volume, position of the burr hole, length of the catheter and its sagittal and coronal angular variations from a theoretical trajectory were measured. The EVD was placed on the right (53 cases) or left (13 cases) side. The mean pre-operative lateral ventricular volume was 51 cc (10-118 cc). The average distance from the burr hole to the midline was 28 mm (10-49 mm) and to the supra-orbital ridge was 101 mm (75-125 mm). The mean intracranial catheter length was 60 mm (from 39-102 mm). Only 50% of the EVDs in the coronal plane and 40% in the sagittal plane were placed with an angular variation of ±5° to the target. The tip was placed outside of the ventricles in three cases; 13 catheters crossed the midline, and five intracranial minor haemorrhages were detected. Freehand placement of EVDs does not have sufficient accuracy and may lead to drainage dysfunctions. This data suggests that a guidance system for EVD's would be required.
Martinek, Martin; Lemes, Christine; Sigmund, Elisabeth; Derndorfer, Michael; Aichinger, Josef; Winter, Siegmund; Nesser, Hans-Joachim; Pürerfellner, Helmut
2012-11-01
Electrode-tissue contact is crucial for adequate lesion formation in radiofrequency catheter ablation (RFCA). We assessed the impact of direct catheter force measurement on acute procedural parameters during RFCA of atrial fibrillation (AF). Fifty consecutive patients (28 male) with paroxysmal AF who underwent their first procedure of circumferential pulmonary vein (PV) isolation (PVI) were assigned to either RFCA using (1) a standard 3.5-mm open-irrigated-tip catheter or (2) a catheter with contact force measurement capabilities. Using the endpoint of PVI with entry and exit block, acute procedural parameters were assessed. Procedural data showed a remarkable decline in ablation time (radiofrequency time needed for PVI) from 50.5 ± 15.9 to 39.0 ± 11.0 minutes (P = 0.007) with a reduction in overall procedure duration from 185 ± 46 to 154 ± 39 minutes (P = 0.022). In parallel, the total energy delivered could be significantly reduced from 70,926 ± 19,470 to 58,511 ± 14,655 Ws (P = 0.019). The number of acute PV reconnections declined from 36% to 12% (P = 0.095). The use of contact force sensing technology is able to significantly reduce ablation and procedure times in PVI. In addition, energy delivery is substantially reduced by avoiding radiofrequency ablation in positions with insufficient surface contact. Procedural efficacy and safety of this new feature have to be evaluated in larger cohorts. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.
Catheter tip force transducer for cardiovascular research
NASA Technical Reports Server (NTRS)
Feldstein, C.; Lewis, G. W.; Silver, R. H.; Culler, V. H. (Inventor)
1976-01-01
A force transducer for measuring dynamic force activity within the heart of a subject essentially consists of a U-shaped beam of low elastic compliance material. Two lines extend from the beams's legs and a long coil spring is attached to the beam. A strain gauge is coupled to one of the beam's legs to sense deflections thereof. The beam with the tines and most of the spring are surrounded by a flexible tube, defining a catheter, which is insertable into a subject's heart through an appropriate artery. The tines are extractable from the catheter for implantation into the myocardium by pushing on the end of the spring which extends beyond the external end of the catheter.
Extravasation from venous catheter: a serious complication potentially missed by lung imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spicer, K.M.; Gordon, L.
Three patients were referred for lung ventiliation and perfusion (V/Q) imaging with symptoms strongly suggestive of pulmonary embolus (PE). Chest roentgenograms and xenon ventilation studies on all three were normal, save for prominent mediastinal silhouettes and effusions. Technetium-99m macroaggregated albumin(Tc-99m MAA), when injected through the central venous catheter (CVP), revealed mediastinal localization, whereas antecubital injections showed normal pulmonary perfusion. Contrast fluoroscopy introduced through the venous catheter in the first patient defined the extravasation. For patients under strong suspicion of PE, with a venous catheter whose distal tip is seen about the level of the heart on chest radiograph, the authorsmore » recommend administering the perfusion agent slowly through the central catheter to exclude catheter-induced complications. When extravasation is detected, injection of Tc-99m MAA by peripheral vein should be used to exclude PE.« less
The Development for Polymer Actuator Active Catheter System
Sewa, S.; Onishi, K.; Oguro, K.; Asaka, K.; Taki, W.; Toma, N.
2001-01-01
Summary Electric stimuli polymer-metal composite actuator material has been developed for active catheter system and other widely new applications. The polymer actuator is made of ion exchange polymer and gold as electrode, and a pulse voltage of 3 volts on the actuator gave a quick bend 90 degree angle. This composite material is possible to make small size, light and soft actuator. So now we can actually develop an active catheter for the interventional radiology surgery. The prototype polymer actuator active catheter has been developed by using polymer actuator technology and Micro Electronics Mechanical System (MEMS) technologies. The active catheter is controllable from the outside of the body by electric signal. The tip part of the catheter is made of the polymer actuator tube and bends 90 degree angles. The animal tests (dog) showed good actuator performance to control right direction and bending angle at bifurcation of blood vessel and aneurysms. PMID:20663388
Peritoneal dialysis catheter implantation: avoiding problems and optimizing outcomes.
Crabtree, John H
2015-01-01
The success of peritoneal dialysis (PD) as renal replacement therapy is dependent upon the patient having a functional long-term peritoneal access. There are a number of identified best practices that must be adhered to during PD catheter placement to achieve a durable and infection-resistant access. The clinical setting, available resources, and the employed catheter insertion method may not always permit complete adherence to these practices; however, an attempt should be made to comply with them as closely as possible. Although omission of any one of the practices can lead to catheter loss, departures from some are committed more frequently, manifesting as commonly occurring clinical problems, such as drain pain, catheter tip migration, omental entrapment, pericatheter leaks and hernias, and poor exit-site location. Understanding the technical pitfalls in PD catheter placement that lead to these problems, enable the provider to modify practice habits to avoid them and optimize outcomes. © 2014 Wiley Periodicals, Inc.
Alamri, A; Hyodo, A; Suzuki, K; Tanaka, Y; Uchida, T; Takano, I; Kowata, K; Iwatate, K; Suzuki, R
2012-11-01
To date, the "monorail snare technique" for the retrieval of entombed microcatheter tips during Onyx(TM) (ev3, Irvine, CA) embolisation of brain arteriovenous malformations (BAVM) has not been described. We report our experiences and some technical aspects in using this technique for the retrieval of entombed Marathon(TM) microcatheter (ev3, Plymouth, MN) tips during Onyx embolisation of BAVM treatment. Onyx was used in the embolisation of 11 patients using 25 feeders over 14 sessions. The 'monorail snare technique' was employed for 14 feeders. Each time, an Amplatz 4 mm Gooseneck Microsnare(TM) (ev3, Plymouth, MN) was loaded into an Excelsior 1018(TM) microcatheter (Boston Scientific, Natick, MA). The Marathon microcatheter was cut just distal to the hub, and the Amplatz/Excelsior combination was introduced along the length of the Marathon microcatheter towards its distal end, as far as possible. The embedded catheter was ensnared and both catheters were pulled free. Microcatheter tip removal was successful in all cases, except for one microcatheter tip becoming detached and needing no further intervention. There were no complications as a direct result of the snare technique. The monorail snare technique is a safe and easy technique for retrieving Onyx-encased microcatheter tips in the treatment of BAVM.
Rath, Chandra Prakash; Thomas, Mary; Sullivan, Drew; Kluckow, Martin
2018-05-28
To compare thyroid function tests in preterm neonates (<30 weeks and >48 hour old) exposed to iodine-based contrast with controls and ascertain the certainty of peripherally inserted central catheter (PICC) tip position. Infants requiring a PICC were randomised to receive 0.3 mL of iodine-containing contrast or normal saline. The primary outcome was the difference in thyroid-stimulating hormone (TSH) levels on day 14 post PICC insertion and on day 28 of life. 41 infants were randomised with no significant differences in TSH level (mIU/L) at day 14 post PICC insertion (3.1 vs 2) or on day 28 of life (2.2 vs 1.7). The PICC tip was more easily localised in the contrast group (85% vs 55%). Urinary iodine levels were significantly increased in the contrast-exposed group. Use of contrast did not suppress subsequent thyroid function and helped visualise the PICC tip with more certainty. ACTRN 12614000560695, pre-result. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, S; Kamrava, M; Yang, Y
Purpose: To evaluate the accuracy of interstitial catheter reconstruction with 0.35T MRI images for MRI-based HDR prostate brachytherapy. Methods: Recently, a real-time MRI-guided radiotherapy system combining a 0.35T MRI system and three cobalt 60 heads (MRIdian System, ViewRay, Cleveland, OH, USA) was installed in our department. A TrueFISP sequence for MRI acquisition at lower field on Viewray was chosen due to its fast speed and high signal-to-noise efficiency. Interstitial FlexiGuide needles were implanted into a tissue equivalent ultrasound prostate phantom (CIRS, Norfolk, Virginia, USA). After an initial 15s pilot MRI to confirm the location of the phantom, planning MRI wasmore » acquired with a 172s TrueFISP sequence. The pulse sequence parameters included: flip angle = 60 degree, echo time (TE) =1.45 ms, repetition time (TR) = 3.37 ms, slice thickness = 1.5 mm, field of view (FOV) =500 × 450mm. For a reference image, a CT scan was followed. The CT and MR scans were then fused with the MIM Maestro (MIM software Inc., Cleveland, OH, USA) and sent to the Oncentra Brachy planning system (Elekta, Veenendaal, Netherlands). Automatic catheter reconstruction using CT and MR image intensities followed by manual reconstruction was used to digitize catheters. The accuracy of catheter reconstruction was evaluated from the catheter tip location. Results: The average difference between the catheter tip locations reconstructed from the CT and MR in the transverse, anteroposterior, and craniocaudal directions was −0.1 ± 0.1 mm (left), 0.2 ± 0.2 mm (anterior), and −2.3 ± 0.5 mm (cranio). The average distance in 3D was 2.3 mm ± 0.5 mm. Conclusion: This feasibility study proved that interstitial catheters can be reconstructed with 0.35T MRI images. For more accurate catheter reconstruction which can affect final dose distribution, a systematic shift should be applied to the MR based catheter reconstruction in HDR prostate brachytherapy.« less
Compensation for Unconstrained Catheter Shaft Motion in Cardiac Catheters
Degirmenci, Alperen; Loschak, Paul M.; Tschabrunn, Cory M.; Anter, Elad; Howe, Robert D.
2016-01-01
Cardiac catheterization with ultrasound (US) imaging catheters provides real time US imaging from within the heart, but manually navigating a four degree of freedom (DOF) imaging catheter is difficult and requires extensive training. Existing work has demonstrated robotic catheter steering in constrained bench top environments. Closed-loop control in an unconstrained setting, such as patient vasculature, remains a significant challenge due to friction, backlash, and physiological disturbances. In this paper we present a new method for closed-loop control of the catheter tip that can accurately and robustly steer 4-DOF cardiac catheters and other flexible manipulators despite these effects. The performance of the system is demonstrated in a vasculature phantom and an in vivo porcine animal model. During bench top studies the robotic system converged to the desired US imager pose with sub-millimeter and sub-degree-level accuracy. During animal trials the system achieved 2.0 mm and 0.65° accuracy. Accurate and robust robotic navigation of flexible manipulators will enable enhanced visualization and treatment during procedures. PMID:27525170
A 10-Fr ultrasound catheter with integrated micromotor for 4-D intracardiac echocardiography.
Lee, Warren; Griffin, Weston; Wildes, Douglas; Buckley, Donald; Topka, Terry; Chodakauskas, Thaddeus; Langer, Mark; Calisti, Serge; Bergstøl, Svein; Malacrida, Jean-Pierre; Lanteri, Frédéric; Maffre, Jennifer; McDaniel, Ben; Shivkumar, Kalyanam; Cummings, Jennifer; Callans, David; Silvestry, Frank; Packer, Douglas
2011-07-01
We developed prototype real-time 3-D intracardiac echocardiography catheters with integrated micromotors, allowing internal oscillation of a low-profile 64-element, 6.2-MHz phased-array transducer in the elevation direction. Components were designed to facilitate rotation of the array, including a low-torque flexible transducer interconnect and miniature fixtures for the transducer and micromotor. The catheter tip prototypes were integrated with two-way deflectable 10-Fr catheters and used in in vivo animal testing at multiple facilities. The 4-D ICE catheters were capable of imaging a 90° azimuth by up to 180° elevation field of view. Volume rates ranged from 1 vol/sec (180° elevation) to approximately 10 vol/sec (60° elevation). We successfully imaged electrophysiology catheters, atrial septal puncture procedures, and detailed cardiac anatomy. The elevation oscillation enabled 3-D visualization of devices and anatomy, providing new clinical information and perspective not possible with current 2-D imaging catheters.
Maurer, Tilman; Rottner, Laura; Makimoto, Hisaki; Reissmann, Bruno; Heeger, Christian-H; Lemes, Christine; Fink, Thomas; Riedl, Johannes; Santoro, Francesco; Wohlmuth, Peter; Volkmer, Marius; Mathew, Shibu; Metzner, Andreas; Ouyang, Feifan; Kuck, Karl-Heinz; Sohns, Christian
2018-05-08
This study aimed to evaluate feasibility and safety as well as 1-year clinical outcome of pulmonary vein isolation (PVI) using a unique radiofrequency ablation catheter ("Thermocool SmartTouch SurroundFlow"; STSF) incorporating both, contact force (CF) sensing technology and enhanced tip irrigation with 56 holes, in one device. A total of 110 patients suffering from drug-refractory atrial fibrillation underwent wide area circumferential PVI using either the STSF ablation catheter (75 consecutive patients, study group) or a CF catheter with conventional tip irrigation ("Thermocool SmartTouch", 35 consecutive patients, control group). For each ablation lesion, a target CF of ≥ 10-39 g and a force time integral (FTI) of > 400 g s was targeted. Acute PVI was achieved in all patients with target CF obtained in > 85% of ablation points when using either device. Mean procedure time (131.3 ± 33.7 min in the study group vs. 133.0 ± 42.0 min in the control group; p = 0.99), mean fluoroscopy time (14.0 ± 6 vs. 13.5 ± 6.6 min; p = 0.56) and total ablation time were not significantly different (1751.0 ± 394.0 vs. 1604.6 ± 287.8 s; p = 0.2). However, there was a marked reduction in total irrigation fluid delivery by 51.7% (265.52 ± 64.4 vs. 539.6 ± 118.2 ml; p < 0.01). The Kaplan-Meier estimate 12-month arrhythmia-free survival after the index procedure following a 3-month blanking period was 79.9% (95% CI 70.4%, 90.4%) for the study group and 66.7% for the control group (95% CI 50.2%, 88.5%). This finding did not reach statistical significance (p = 0.18). Major complications occurred in 2/75 patients (2.7%; one pericardial tamponade and one transient ischemic attack) in the study group and no patient in the control group (p = 18). PVI using the STSF catheter is safe and effective and results in beneficial 1-year clinical outcome. The improved tip irrigation leads to a significant reduction in procedural fluid burden.
Jularic, Mario; Akbulak, Ruken Özge; Schäffer, Benjamin; Moser, Julia; Nuehrich, Jana; Meyer, Christian; Eickholt, Christian; Willems, Stephan; Hoffmann, Boris A
2018-03-01
During ablation in the vicinity of the coronary arteries establishing a safe distance from the catheter tip to the relevant vessels is mandatory and usually assessed by fluoroscopy alone. The aim of the study was to investigate the feasibility of an image integration module (IIM) for continuous monitoring of the distance of the ablation catheter tip to the main coronary arteries during ablation of ventricular arrhythmias (VA) originating in the sinus of valsalva (SOV) and the left ventricular summit part of which can be reached via the great cardiac vein (GCV). Of 129 patients undergoing mapping for outflow tract arrhythmias from June 2014 till October 2015, a total of 39 patients (52.4 ± 18.1 years, 17 female) had a source of origin in the SOV or the left ventricular summit. Radiofrequency (RF) ablation was performed when a distance of at least 5 mm could be demonstrated with IIM. A safe distance in at least one angiographic plane could be demonstrated in all patients with a source of origin in the SOV, whereas this was not possible in 50% of patients with earliest activation in the summit area. However, using the IIM a safe position at an adjacent site within the GCV could be obtained in three of these cases and successful RF ablation performed safely without any complications. Ablation was successful in 100% of patients with an origin in the SOV, whereas VAs originating from the left ventricular summit could be abolished completely in only 60% of cases. Image integration combining electroanatomical mapping and fluoroscopy allows assessment of the safety of a potential ablation site by continuous real-time monitoring of the spatial relations of the catheter tip to the coronary vessels prior to RF application. It aids ablation in anatomically complex regions like the SOV or the ventricular summit providing biplane angiograms merged into the three-dimensional electroanatomical map. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Baghdadchi, Saharnaz; Chao, Cherng; Esener, Sadik; Mattrey, Robert F.; Eghtedari, Mohammad A.
2017-02-01
Image-guided procedures are performed frequently by radiologists to insert a catheter within a target vessel or lumen or to perform biopsy of a lesion. For instance, an interventional radiologist uses fluoroscopy during percutaneous biliary drainage procedure (a procedure during which a catheter is inserted through the skin to drain the bile from liver) to identify the location of the needle tip within liver parenchyma, hepatic blood vessel or bile duct. However, the identification of the target organ under fluoroscopy exposes the patient to x-ray irradiation, which may be significant if the time of procedure is prolonged. We have designed a fiber core needle system that may help the radiologist identify the location of the needle tip in real time without exposing the patient to x-ray. Our needle system transmits a low power modulated light into the tissue through a fiber cable embedded in the needle and detects the backscattered light using another fiber inside the needle. We were able to successfully distinguish the location of our prototype needle tip inside a cow liver phantom to identify if the needle tip was within liver parenchyma, liver vessels, or in the bile duct based on the recorded backscattered light.
Design, development and evaluation of a compact telerobotic catheter navigation system.
Tavallaei, Mohammad Ali; Gelman, Daniel; Lavdas, Michael Konstantine; Skanes, Allan C; Jones, Douglas L; Bax, Jeffrey S; Drangova, Maria
2016-09-01
Remote catheter navigation systems protect interventionalists from scattered ionizing radiation. However, these systems typically require specialized catheters and extensive operator training. A new compact and sterilizable telerobotic system is described, which allows remote navigation of conventional tip-steerable catheters, with three degrees of freedom, using an interface that takes advantage of the interventionalist's existing dexterity skills. The performance of the system is evaluated ex vivo and in vivo for remote catheter navigation and ablation delivery. The system has absolute errors of 0.1 ± 0.1 mm and 7 ± 6° over 100 mm of axial motion and 360° of catheter rotation, respectively. In vivo experiments proved the safety of the proposed telerobotic system and demonstrated the feasibility of remote navigation and delivery of ablation. The proposed telerobotic system allows the interventionalist to use conventional steerable catheters; while maintaining a safe distance from the radiation source, he/she can remotely navigate the catheter and deliver ablation lesions. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
A deflectable guiding catheter for real-time MRI-guided interventions
Bell, Jamie A.; Saikus, Christina E.; Ratnakaya, Kanishka; Wu, Vincent; Sonmez, Merdim; Faranesh, Anthony Z.; Colyer, Jessica H.; Lederman, Robert J.; Kocaturk, Ozgur
2011-01-01
Purpose To design a deflectable guiding catheter that omits long metallic components yet preserves mechanical properties to facilitate therapeutic interventional MRI procedures. Materials and Methods The catheter shaft incorporated Kevlar braiding. 180° deflection was attained with a 5 cm nitinol slotted tube, a nitinol spring, and a Kevlar pull string. We tested three designs: passive, passive incorporating an inductively-coupled coil, and active receiver. We characterized mechanical properties, MRI properties, RF induced heating, and in vivo performance in swine. Results Torque and tip deflection force were satisfactory. Representative procedures included hepatic and azygos vein access, laser cardiac septostomy, and atrial septal defect crossing. Visualization was best in the active configuration, delineating profile and tip orientation. The passive configuration could be used in tandem with an active guidewire to overcome its limited conspicuity. There was no RF-induced heating in all configurations under expected use conditions in vitro and in vivo. Conclusion Kevlar and short nitinol component substitutions preserved mechanical properties. The active design offered the best visibility and usability but reintroduced metal conductors. We describe versatile deflectable guiding catheters with a 0.057” lumen for interventional MRI catheterization. Implementations are feasible using active, inductive, and passive visualization strategies to suit application requirements. PMID:22128071
Valdigem, Bruno Pereira; da Silva, Nilton José Carneiro; Dietrich, Cristiano Oliveira; Moreira, Dalmo; Sasdelli, Roberto; Pinto, Ibraim M; Cirenza, Claudio; de Paola, Angelo Amato Vincenzo
2010-11-01
As damage to coronary arteries is a potential complication of epicardial RF catheter ablation (EPRFCA), the procedure must be associated with coronary angiography. Chronic Chagasic cardiomiopathy (CCC) is a disease where epicardial VT are common. Eletroanatomic mapping merged with computed totmography (CT) scan data is a useful tool for mapping the endocardium, and its accuracy in guiding ablation on the epicardium was not adequately evaluated so far. Compare electronatomic map merged with Heart CT to fluoroscopy for epicardial ablation of CCC. Describe the distribution of the scars on CCC. We performed epicardial and endocardial mapping and ablation using CARTO XP V8 on eight patients and merged the map with coronary arteries CT scan using at least three landmarks. To compare the 3D image obtained with CARTO MERGE and the 2D fluoroscopic image obtained during the ablation procedure, we used computer graphic software (Inkscape™) in order to prove that the images were equivalent and to compare the distance between the catheter tip on fluoroscopy to catheter tip on 3D EA map. EPRFCA was successfully performed in all patients and they did not present recurrence for at least 3-month follow-up. The mean difference between the tip of the catheter on fluoroscopy and on the 3D model was 6.03 ± 2.09 mm. Scars were present in the epicardium and endocardium and most of patients presented with posterior wall scars and RV scar. The combination of electroanatomic map and CT coronary artery scan data is feasible and can be an important tool for EPRFCA in patients with CCC and VT.
NASA Astrophysics Data System (ADS)
Baka, N.; Lelieveldt, B. P. F.; Schultz, C.; Niessen, W.; van Walsum, T.
2015-05-01
During percutaneous coronary interventions (PCI) catheters and arteries are visualized by x-ray angiography (XA) sequences, using brief contrast injections to show the coronary arteries. If we could continue visualizing the coronary arteries after the contrast agent passed (thus in non-contrast XA frames), we could potentially lower contrast use, which is advantageous due to the toxicity of the contrast agent. This paper explores the possibility of such visualization in mono-plane XA acquisitions with a special focus on respiratory based coronary artery motion estimation. We use the patient specific coronary artery centerlines from pre-interventional 3D CTA images to project on the XA sequence for artery visualization. To achieve this, a framework for registering the 3D centerlines with the mono-plane 2D + time XA sequences is presented. During the registration the patient specific cardiac and respiratory motion is learned. We investigate several respiratory motion estimation strategies with respect to accuracy, plausibility and ease of use for motion prediction in XA frames with and without contrast. The investigated strategies include diaphragm motion based prediction, and respiratory motion extraction from the guiding catheter tip motion. We furthermore compare translational and rigid respiratory based heart motion. We validated the accuracy of the 2D/3D registration and the respiratory and cardiac motion estimations on XA sequences of 12 interventions. The diaphragm based motion model and the catheter tip derived motion achieved 1.58 mm and 1.83 mm median 2D accuracy, respectively. On a subset of four interventions we evaluated the artery visualization accuracy for non-contrast cases. Both diaphragm, and catheter tip based prediction performed similarly, with about half of the cases providing satisfactory accuracy (median error < 2 mm).
Tewari, Ashutosh; Rao, Sandhya; Mandhani, Anil
2008-09-01
To study the feasibility of avoiding a urethral catheter after robotic radical prostatectomy by using suprapubic diversion with a urethral splint, as urethral catheterization is often a source of major discomfort and pain to the patient, and can cause more concern to the patient than the procedure; we present the outcomes of a pilot study. This pilot study involved 30 patients; in group 1 (the study group of 10 patients) we used a custom-made suprapubic catheter which provided a small anastomotic splint, multiple holes for drainage and the ability to retract the splint to give a voiding trial before removing the drainage device. Group 2 was a control group of 20 patients who had standard urethral catheterization with an 18 F Silastic Foley catheter. Demographic, intraoperative and outcome data were measured and analysed. Urethral symptoms were recorded using a specially developed questionnaire. The two groups were comparable in terms of age, serum prostate specific antigen level, body mass index, Gleason scores, tumour stage, operative duration, amount of bleeding, console times, anastomotic leakage and postoperative retention rates. The study group had significantly less penile shaft or tip pain and discomfort during walking or sleeping. No patient in either group had haematuria or clot retention requiring irrigation. Urethral catheter-less robotic radical prostatectomy is feasible. The advantages are decreased penile shaft and tip pain, and decreased patient discomfort and an earlier return of continence.
Catheter-based photoacoustic endoscope
Yang, Joon-Mo; Li, Chiye; Chen, Ruimin; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.
2014-01-01
Abstract. We report a flexible shaft-based mechanical scanning photoacoustic endoscopy (PAE) system that can be potentially used for imaging the human gastrointestinal tract via the instrument channel of a clinical video endoscope. The development of such a catheter endoscope has been an important challenge to realize the technique’s benefits in clinical settings. We successfully implemented a prototype PAE system that has a 3.2-mm diameter and 2.5-m long catheter section. As the instrument’s flexible shaft and scanning tip are fully encapsulated in a plastic catheter, it easily fits within the 3.7-mm diameter instrument channel of a clinical video endoscope. Here, we demonstrate the intra-instrument channel workability and in vivo animal imaging capability of the PAE system. PMID:24887743
Navigation with Electromagnetic Tracking for Interventional Radiology Procedures
Wood, Bradford J.; Zhang, Hui; Durrani, Amir; Glossop, Neil; Ranjan, Sohan; Lindisch, David; Levy, Eliott; Banovac, Filip; Borgert, Joern; Krueger, Sascha; Kruecker, Jochen; Viswanathan, Anand; Cleary, Kevin
2008-01-01
PURPOSE To assess the feasibility of the use of preprocedural imaging for guide wire, catheter, and needle navigation with electromagnetic tracking in phantom and animal models. MATERIALS AND METHODS An image-guided intervention software system was developed based on open-source software components. Catheters, needles, and guide wires were constructed with small position and orientation sensors in the tips. A tetrahedral-shaped weak electromagnetic field generator was placed in proximity to an abdominal vascular phantom or three pigs on the angiography table. Preprocedural computed tomographic (CT) images of the phantom or pig were loaded into custom-developed tracking, registration, navigation, and rendering software. Devices were manipulated within the phantom or pig with guidance from the previously acquired CT scan and simultaneous real-time angiography. Navigation within positron emission tomography (PET) and magnetic resonance (MR) volumetric datasets was also performed. External and endovascular fiducials were used for registration in the phantom, and registration error and tracking error were estimated. RESULTS The CT scan position of the devices within phantoms and pigs was accurately determined during angiography and biopsy procedures, with manageable error for some applications. Preprocedural CT depicted the anatomy in the region of the devices with real-time position updating and minimal registration error and tracking error (<5 mm). PET can also be used with this system to guide percutaneous biopsies to the most metabolically active region of a tumor. CONCLUSIONS Previously acquired CT, MR, or PET data can be accurately codisplayed during procedures with reconstructed imaging based on the position and orientation of catheters, guide wires, or needles. Multimodality interventions are feasible by allowing the real-time updated display of previously acquired functional or morphologic imaging during angiography, biopsy, and ablation. PMID:15802449
Malinova, Vesna; Schlegel, Anna; Rohde, Veit; Mielke, Dorothee
2017-07-01
For the fibrinolytic therapy of intracerebral hematomas (ICH) using recombinant tissue plasminogen activator (rtPA), a catheter position in the core of the hematoma along the largest clot diameter was assumed to be optimal for an effective clot lysis. However, it never had been proven that core position indeed enhances clot lysis if compared with less optimal catheter positions. In this study, the impact of the catheter position on the effectiveness and on the time course of clot lysis was evaluated. We analyzed the catheter position using a relative error calculating the distance perpendicular to the catheter's center in relation to hematoma's diameter and evaluated the relative hematoma volume reduction (RVR). The correlation of the RVR with the catheter position was evaluated. Additionally, we tried to identify patterns of clot lysis with different catheter positions. The patient's outcome at discharge was evaluated using the Glasgow outcome score. A total of 105 patients were included in the study. The mean hematoma volume was 56 ml. The overall RVR was 62.7 %. In 69 patients, a catheter position in the core of the clot was achieved. We found no significant correlation between catheter position and hematoma RVR (linear regression, p = 0.14). Core catheter position leads to more symmetrical hematoma RVR. Faster clot lysis happens in the vicinity of the catheter openings. We found no significant difference in the patient's outcome dependent on the catheter position (linear regression, p = 0.90). The catheter position in the core of the hematoma along its largest diameter does not significantly influence the effectiveness of clot lysis after rtPA application.
[Methods of resolution for haptic assistance during catheterization].
Kern, T A; Herrmann, J; Klages, S; Meiss, T; Werthschützky, R
2005-01-01
During catheterization navigation within the patient is mainly dependent on a live x-ray image on the screen. Although methods for 3D visualisation and remote navigation of the catheter are discussed and tested still precise positioning is merely the result of intense training and a high skill and level of training of the performing surgeon. This article refers to a system which can be considered as an add-on for existing procedures of catheterization. It compromises of a miniaturised force sensor located at the tip of guide-wires whose prototype is shown here. The measured forces will be presented to the surgeon amplified by an external actuator described in this article. As a result a haptic perception of the forces between the tip of the guide-wire and the vessels walls will be available and enable the surgeon to gain an impression which is comparable to palpation of living vessels from the inside
Using a wireless motion controller for 3D medical image catheter interactions
NASA Astrophysics Data System (ADS)
Vitanovski, Dime; Hahn, Dieter; Daum, Volker; Hornegger, Joachim
2009-02-01
State-of-the-art morphological imaging techniques usually provide high resolution 3D images with a huge number of slices. In clinical practice, however, 2D slice-based examinations are still the method of choice even for these large amounts of data. Providing intuitive interaction methods for specific 3D medical visualization applications is therefore a critical feature for clinical imaging applications. For the domain of catheter navigation and surgery planning, it is crucial to assist the physician with appropriate visualization techniques, such as 3D segmentation maps, fly-through cameras or virtual interaction approaches. There has been an ongoing development and improvement for controllers that help to interact with 3D environments in the domain of computer games. These controllers are based on both motion and infrared sensors and are typically used to detect 3D position and orientation. We have investigated how a state-of-the-art wireless motion sensor controller (Wiimote), developed by Nintendo, can be used for catheter navigation and planning purposes. By default the Wiimote controller only measure rough acceleration over a range of +/- 3g with 10% sensitivity and orientation. Therefore, a pose estimation algorithm was developed for computing accurate position and orientation in 3D space regarding 4 Infrared LEDs. Current results show that for the translation it is possible to obtain a mean error of (0.38cm, 0.41cm, 4.94cm) and for the rotation (0.16, 0.28) respectively. Within this paper we introduce a clinical prototype that allows steering of a virtual fly-through camera attached to the catheter tip by the Wii controller on basis of a segmented vessel tree.
Positive deviance as a strategy to prevent and control bloodstream infections in intensive care.
Oliveira, Francimar Tinoco de; Ferreira, Maria Manuela Frederico; Araújo, Silvia Teresa Carvalho de; Bessa, Amanda Trindade Teixeira de; Moraes, Advi Catarina Barbachan; Stipp, Marluci Andrade Conceição
2017-04-03
To describe the application of positive deviance as a strategy to prevent and control bloodstream infections. An intervention study with nursing and medical team members working in an intensive care unit in a university hospital, between June and December 2014. The four steps of the positive defiance methodology were applied: to define, to determine, to discover and to design. In 90 days, 188 actions were observed, of these, 36.70% (n=69) were related to catheter dressing. In 81.15% (n=56) of these dressings, the professionals most adhered to the use of flexible sterile cotton-tipped swabs to perform antisepsis at catheter entry sites and fixation dressing. Positive deviance contributed to the implementation of proposals to improve work processes and team development related to problems identified in central venous catheter care. Descrever a aplicação do Positive Deviance como estratégia na prevenção e no controle da infecção de corrente sanguínea. Estudo de intervenção realizado na Unidade de Terapia Intensiva de um hospital universitário, com os membros das equipes de enfermagem e médica, de junho a dezembro de 2014. Foram aplicados os quatro passos da metodologia Positive Deviance: Definir, Determinar, Descobrir e Desenhar. Em 90 dias 188 ações foram observadas, destas, 36,70% (n=69) estavam relacionadas aos curativos dos cateteres. Em 81,15% (n=56) desses curativos, o uso da haste flexível estéril para realização da antissepsia do local de inserção do cateter e de sua placa de fixação foi a ação de maior adesão. O Positive Deviance auxiliou na implementação de propostas de melhorias de processo de trabalho e no desenvolvimento da equipe para os problemas identificados no cuidado com o cateter venoso central.
Paravertebral block catheter breakage by electrocautery during thoracic surgery.
Saeki, Noboru; Sugimoto, Yuki; Mori, Yoko; Kato, Takahiro; Miyoshi, Hirotsugu; Nakamura, Ryuji; Koga, Tomomichi
2017-06-01
Advantages of thoracic paravertebral analgesia (TPA) include placement of the catheter closer to the surgical field; however, the catheter can become damaged during the operation. We experienced a case of intraoperative TPA catheter breakage that prompted us to perform an experiment to investigate possible causes. A 50-year-old male underwent a thoracoscopic lower lobectomy under general anesthesia with TPA via an intercostal approach. Following surgery, it was discovered that the catheter had become occluded, as well as cut and fused, so we reopened the incision and removed the residual catheter. From that experience, we performed an experiment to examine electrocautery-induced damage in normal (Portex™, Smith's Medical), radiopaque (Perifix SoftTip™, BBraun), and reinforced (Perifix FX™, BBraun) epidural catheters (n = 8 each). Chicken meat was penetrated by each catheter and then cut by electrocautery. In the normal group, breakage occurred in 8 and occlusion in 6 of the catheters, and in the radiopaque group breakage occurred in 8 and occlusion in 7. In contrast, breakage occurred in only 3 and occlusion in none in the reinforced group, with the 5 without breakage remaining connected only by the spring coil. Furthermore, in 7 of the reinforced catheters, electric arc-induced thermal damage was observed at the tip of the catheter. A TPA catheter for thoracic surgery should be inserted via the median approach, or it should be inserted after surgery to avoid catheter damage during surgery.
Liu, Taoming; Poirot, Nate Lombard; Franson, Dominique; Seiberlich, Nicole; Griswold, Mark A.; Çavuşoğlu, M. Cenk
2016-01-01
Objective This paper presents the three dimensional kinematic modeling of a novel steerable robotic ablation catheter system. The catheter, embedded with a set of current-carrying micro-coils, is actuated by the magnetic forces generated by the magnetic field of the magnetic resonance imaging (MRI) scanner. Methods This paper develops a 3D model of the MRI actuated steerable catheter system by using finite differences approach. For each finite segment, a quasi-static torque-deflection equilibrium equation is calculated using beam theory. By using the deflection displacements and torsion angles, the kinematic model of the catheter system is derived. Results The proposed models are validated by comparing the simulation results of the proposed model with the experimental results of a hardware prototype of the catheter design. The maximum tip deflection error is 4.70 mm and the maximum root-mean-square (RMS) error of the shape estimation is 3.48 mm. Conclusion The results demonstrate that the proposed model can successfully estimate the deflection motion of the catheter. Significance The presented three dimensional deflection model of the magnetically controlled catheter design paves the way to efficient control of the robotic catheter for treatment of atrial fibrillation. PMID:26731519
NASA Astrophysics Data System (ADS)
Salgaonkar, Vasant A.; Nazer, Babak; Jones, Peter D.; Tanaka, Yasuaki; Martin, Alastair; Ng, Bennett; Duggirala, Srikant; Diederich, Chris J.; Gerstenfeld, Edward P.
2015-03-01
The development and in vivo testing of a high-intensity ultrasound thermal ablation catheter for epicardial ablation of the left ventricle (LV) is presented. Scar tissue can occur in the mid-myocardial and epicardial space in patients with nonischemic cardiomyopathy and lead to ventricular tachycardia. Current ablation technology uses radiofrequency energy, which is limited epicardially by the presence of coronary vessels, phrenic nerves, and fat. Ultrasound energy can be precisely directed to deliver targeted deep epicardial ablation while sparing intervening epicardial nerve and vessels. The proof-of-concept ultrasound applicators were designed for sub-xyphoid access to the pericardial space through a steerable 14-Fr sheath. The catheter consists of two rectangular planar transducers, for therapy (6.4 MHz) and imaging (5 MHz), mounted at the tip of a 3.5-mm flexible nylon catheter coupled and encapsulated within a custom-shaped balloon for cooling. Thermal lesions were created in the LV in a swine (n = 10) model in vivo. The ultrasound applicator was positioned fluoroscopically. Its orientation and contact with the LV were verified using A-mode imaging and a radio-opaque marker. Ablations employed 60-s exposures at 15 - 30 W (electrical power). Histology indicated thermal coagulation and ablative lesions penetrating 8 - 12 mm into the left ventricle on lateral and anterior walls and along the left anterior descending artery. The transducer design enabled successful sparing from the epicardial surface to 2 - 4 mm of intervening ventricle tissue and epicardial fat. The feasibility of targeted epicardial ablation with catheter-based ultrasound was demonstrated.
Augusto, Renan Maloni; Albuquerque, André Luis Pereira; Jaeger, Thomas; de Carvalho, Carlos Roberto Ribeiro; Caruso, Pedro
2017-02-01
The use of esophageal catheters with microtransducer promises advantages over traditional catheters with air-filled balloons. However, performance comparisons between these 2 types of catheters are scarce and incomplete. A catheter with a 9.5-cm air-filled balloon at the distal tip and a catheter with a microtransducer mounted within a flexible silicone rubber were tested in vitro and in vivo. In vitro, the response times of both catheters were compared, and the drift of the baseline pressure of the microtransducer catheter was evaluated over a 6-h period. In vivo, 11 healthy volunteers had both catheters inserted, and the drift of the baseline esophageal pressure was measured over a 3-h period. Also, the correlation and agreement of the baseline and changes in the esophageal pressure of both catheters were evaluated. In vitro, the microtransducer catheter had a response time significantly higher (262 × 114 Hz, P < .01) and a good pressure stability, with a mean baseline pressure drift of 1.4 cm H 2 O. In vivo, both catheters presented a small and similar baseline esophageal pressure drift (P = 0.08). For measurements of baseline and changes in esophageal pressure, the correlation and agreement between the catheters were poor, with a large bias between them. The catheter with the microtransducer had a small baseline pressure drift, similar to the air-filled balloon catheter. The low agreement between the catheters does not allow the microtransducer catheter to be used as a surrogate for the traditional air-filled balloon catheter. Copyright © 2017 by Daedalus Enterprises.
Kwon, Hyun-Jung; Jeong, Young-Il; Jun, In-Gu; Moon, Young-Jin; Lee, Yu-Mi
2018-01-01
Abstract Subclavian central venous catheterization is a common procedure for which misplacement of the central venous catheter (CVC) is a frequent complication that can potentially be fatal. The carina is located in the mid-zone of the superior vena cava (SVC) and is considered a reliable landmark for CVC placement in chest radiographs. The C-length, defined as the distance from the edge of the right transverse process of the first thoracic spine to the carina, can be measured in posteroanterior chest radiographs using a picture archiving and communication system. To evaluate the placement of the tip of the CVC in subclavian central venous catheterizations using the C-length, we reviewed the medical records and chest radiographs of 122 adult patients in whom CVC catheterization was performed (from January 2012 to December 2014) via the right subclavian vein using the C-length. The tips of all subclavian CVCs were placed in the SVC using the C-length. No subclavian CVC entered the right atrium. Tip placement was not affected by demographic characteristics such as age, sex, height, weight, and body mass index. The evidence indicates that the C-length on chest radiographs can be used to determine the available insertion length and place the right subclavian CVC tip into the SVC. PMID:29480861
Clemence, Bonnie J; Maneval, Rhonda E
2014-01-01
This is part 1 of a 2-part series of articles that report on the results of a prospective observational cohort study designed to examine the risk factors associated with symptomatic upper extremity deep vein thrombosis (UEDVT) in patients with peripherally inserted central catheters. This article provides an extensive review and critique of the literature that serves to explicate what is currently known about risk factors associated with catheter-related UEDVT. Risk factors such as anticoagulant use, cancer, infection, hypertension, catheter tip placement, and catheter size were identified most frequently in the literature as being associated with UEDVT development. Other risk factors--such as obesity, smoking history, surgery, and presence of pain or edema--were examined in a limited number of studies and lacked consistent evidence of their impact on UEDVT development. The subsequent study that evolved from the review of the literature investigates the relationship between identified risk factors and UEDVT development.
Catheter port cleansing techniques and the entry of povidone-iodine into the epidural space.
Paice, J A; DuPen, A; Schwertz, D
1999-04-01
To determine whether three epidural catheter port cleansing techniques used to apply a povidone-iodine solution differed with respect to the introduction of this solution through the epidural catheter. Experimental. Laboratory. Five DuPen (Davol, Cranston, RI) epidural catheters. Five DuPen epidural catheters each were cleansed twice with (a) a commercially available 10% povidone-iodine swabstick, (b) a commercially available pledget impregnated with 10% povidone-iodine, and (c) a gauze pad saturated with 10% povidone-iodine. The order of cleansing was randomized. Each solution was used to clean the port for 30 seconds, and the port was allowed to dry for 30 seconds, similar to the technique used in the clinical setting. After cleaning the catheter port, water was injected through the catheter, and the solution from the tip of the catheter was analyzed using absorbance spectrophotometry. Cleansing techniques, presence of povidone-iodine in catheter. A statistically significant difference existed between the three cleansing techniques, with the pledget yielding the lowest values of povidone-iodine contamination of the epidural catheter (Freidman test, p = 0.02). Use of pledgets allowed the least amount of povidone-iodine to enter the epidural catheter as compared with the swabsticks or gauze pads. Commercially available pledgets used to cleanse catheter injection ports may limit the introduction of 10% povidone-iodine into the epidural or intrathecal space.
Wood, Paul; Gill, M; Edwards, D; Clifton, P; Bullock, C; Aldington, D
2016-08-01
The adoption of regional and epidural analgesia in UK military personnel injured in action during Op HERRICK increased from 2008, in line with structural and environmental developments in the UK medical treatment facility. Historically, there have been concerns that invasive analgesic techniques could carry an increased risk of infection, due to the mechanism of injury and the environmental conditions in which the injuries were sustained. Consequently, the epidural and continuous peripheral nerve blockade (CPNB) catheters that were inserted in UK military personnel during a 33-month period of Op HERRICK were clinically and microbiologically examined, after subsequent admission to the University Hospitals Birmingham (UHB) NHS Trust. Data on epidural and CPNB insertions were collected via the specialist pain service at UHB over the study period, including de novo and replacement insertions performed in both Afghanistan and the UK. Patients were regularly reviewed and relevant clinical concerns were documented in patients' case notes as necessary. The anatomical site, duration of placement and the results of microbiological culture of the epidural and CPNB catheter tips were all recorded. Overall, 236 catheters were assessed, of which 151 catheter tips (64%) were cultured (85 epidural, 66 CPNB). Of these, 48 grew bacteria (34% of cultured epidurals and 29% of cultured CPNB). There was no difference between the colonisation rates of epidurals inserted in Afghanistan and the UK. Only one infection related to a misplaced epidural catheter was confirmed. With the exception of the epidural (34%) and proximal sciatic (42%) catheters, these figures, in a military cohort characterised by significant injury scores, are consistent with those reported for civilian surgical patients. The results strongly support the expansion of regional analgesia during Op HERRICK from 2008 onwards. The outcomes suggest a possible translation into civilian major trauma practice. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Birch, A A; Eynon, C A; Schley, D
2006-01-01
The objective of this report is to highlight the potential for false pressure measurements from systems that combine intracranial pressure (ICP) measurement and ventricular drainage. If the ports of the drain become blocked to the extent that they present a high resistance to cerebrospinal fluid flow, then a significant pressure gradient between the inside and outside of the catheter may be established. Thus, any intracatheter transducer will faithfully record a pressure much lower than true ICP. This holds true for catheter-tip transducers when the transducer lies inside the catheter. In the absence of flow, however, pressures will equalize; therefore, accurate measurements may be taken if the drain is temporarily closed. We model this situation and provide simulations of expected measurements in such situations; these compare well to observed clinical readings.
[Intrathoracic migration of a ventriculoperitoneal shunt catheter: a case report].
Sánchez-Medina, Yanire; Domínguez-Báez, Jaime; Lazo-Fernández, Eglis; Pérez Del Rosario, Pedro Antonio; Zanabria-Ortiz, Robert
2015-01-01
The intrathoracic complications from ventriculoperitoneal shunt placement are very rare. However, they are potentially serious if not treated. We report the case of thoracic migration of a peritoneal catheter after ventriculoperitoneal shunt and we also review the literature references with discussion of the different mechanisms of shunt-tip migration described. No case of previous sternotomy as in our patient has been found published. All reports recommend early catheter repositioning into the peritoneal cavity after diagnosing the migration described, to prevent worse complications. Moreover, it is important to keep in mind that intrathoracic migration can happen and it is necessary to palpate the catheter continuously during passage through subcutaneous tunnelling to prevent it. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.
Endovascular recanalization of a port catheter-associated superior vena cava syndrome.
Tonak, Julia; Fetscher, Sebastian; Barkhausen, Jörg; Goltz, Jan Peter
2015-01-01
Superior vena cava (SVC) syndrome owing to benign etiology is rare and endovascular techniques have been advocated as the treatment of choice. We report a case of endovascular revascularization of a port catheter-associated complete occlusion of the SVC with reversed flow in the azygos vein. In this setting using a sheath in combination with its dilatator to pass the occlusion of the SVC after neither a diagnostic catheter nor a PTA balloon would pass the lesion may be a valid option. A dual venous approach was established using the right common femoral vein and an indwelling port catheter in the right cephalic vein to dilate and stent the lesion. Finally, a port may be implanted after the revascularization had been successful. Passage through the port catheter-associated occlusion of the SVC was only possible by use of the sheath in combination with its dilatator. A dual venous access by the femoral approach and the indwelling central catheter is helpful in treating a SVC occlusion. Long-term central venous catheters may cause SVC syndrome, especially with a catheter tip located too far cranially. An endovascular revascularization of a complete occlusion of the SVC represents the therapy of choice.
Angioscopy by a new percutaneous transluminal coronary angioscope
NASA Astrophysics Data System (ADS)
Sakurada, Masami; Mizuno, Kyoichi; Miyamoto, Akira; Arakawa, Koh; Satomura, Kimio; Shibuya, Toshio; Yanagida, Shigeki; Okamoto, Yasuyuki; Kurita, Akira; Nakamura, Haruo; Arai, Tsunenori; Suda, Akira; Kikuchi, Makoto; Utsumi, Atsushi; Takeuchi, Kiyoshi; Akai, Yoshiro
1990-07-01
We developed a new percutaneous transluminal coronary angioscopic catheter for visualization of coronary artery.This angioscopic catheter has an inflatable balloon at the distal tip and one - directional angulation mechanism.We performed percutaneous transluminal coronary angioscopy during cardiac catheterization cosecutively in 155 patients. With this angioscope , we could get good'-'fair visualization in 81%(131 of 162 lesions)without major complications.We could investigate the endothelial macropathology of ischemic heart disease such as unstable angina and acute myocardial infarction.
Echogenic Catheters and Embryo Transfer Standardization.
Urbina, Maria Teresa; Benjamin, Isaac; Medina, Randolfo; Lerner, Jorge
2015-05-01
1.To describe the standardization process and protocols of the ET method at our center. 2.To compare the performance of non-echogenic catheters with echogenic catheters during ultrasound-guided ET. Retrospective analysis of 2630 ET performed at UNIFERTES during 1997-2014, to describe standardization process and to compare the percentage of difficult ET between echogenic and non-echogenic catheters. We tested 17 non-echogenic and three echogenic catheters. Many variables were associated with the ease of ET: informed patients, waiting time for the procedure, speculum use, clinical touch, uterine contractions, cervical mucus removal, presence of blood before or after the procedure, full bladder, ultrasound guidance, uterocervical angle, mock transfer, catheter type (soft or hard, echogenic or non-echogenic, with stylet or not), catheter loading technique, duration of embryo loading (time interval since the embryos were removed from the incubator for loading until the catheter is passed to the physician), transfer procedure (time interval from the catheter was handed to the physician until the embryos were discharged in the uterus), catheter tip placement, retained embryos, bed rest after ET, operator´s proficiency. The diversity of catheters used and the percentage of difficult transfers decrease as the use of echogenic catheters increases. This process is necessary to minimize variation, ensure high quality, safe and evidence-based practice, and improve outcomes. To standardize the ET method allowed a quicker and easier transfer. The use of echogenic catheters simplified ET procedures guided by abdominal ultrasound.
Modified laparoscopic placement of peritoneal dialysis catheter with intra-abdominal fixation.
Shen, Quanquan; Jiang, Xinxin; Shen, Xiaogang; Yu, Fangyan; Tu, Qiudi; Chen, Wangfang; Ye, Qing; Behera, Tapas Ranjan; He, Qiang
2017-08-01
Peritoneal dialysis (PD) is a commonly accepted method of treating end-stage renal disease (ESRD). Various laparoscopic techniques for the placement of PD catheter have been described. In this study, we developed a novel modified laparoscopic technique for PD catheter placement and evaluated the early results. A straight Tenckhoff PD catheter was placed employing the modified technique in 39 consecutive patients with ESRD from May 2013 to April 2016. The technique is laparoscopically guided intra-abdominal fixation of the PD catheter tip at one point by using suture passer hernia forceps. Individual information including sex, age, primary disease etiology, complications, surgical duration, morbidity, mortality and catheter survival was collected and analyzed. The modified laparoscopic procedure was effectively performed in all patients with a mean operative time of 45 ± 7 min. No conversions from laparoscopy to open surgery of catheter placement occurred. There was one case showing early pericatheter leakage. There were no serious complications, such as bleeding, abdominal wall hernias, distal catheter cuff extrusion and infections of the exit site or tunnel during surgery or the postoperative duration. No mortality was observed in this group of patients. The 6-month follow-up study showed 100% catheter-related complication-free survival. Our modified laparoscopic intra-abdominal fixation technique using suture passer hernia forceps is a simple and safe method for PD catheter placement and is effective in minimizing the risk of catheter migration.
Minaga, Kosuke; Kitano, Masayuki; Itonaga, Masahiro; Imai, Hajime; Miyata, Takeshi; Yamao, Kentaro; Tamura, Takashi; Nuta, Junya; Warigaya, Kenji; Kudo, Masatoshi
2017-12-08
This study was designed to evaluate the feasibility and safety of a newly designed self-expandable metal stent for endoscopic ultrasound-guided biliary drainage (EUS-BD) when it was delivered via three different stent delivery systems: a 7.5Fr delivery catheter with a bullet-shaped tip (7.5Fr-bullet), a 7Fr catheter with a bullet-shaped tip (7Fr-bullet), or a 7Fr catheter with a tee-shaped tip (7Fr-tee). This experimental study utilized a porcine model of biliary dilatation involving ten pigs. In the animal study, technical feasibility and clinical outcomes of the stent when placed with each of the delivery systems were examined. In addition, a phantom model was used to measure the resistance of these delivery systems to advancement. Phantom experiments showed that, compared with 7Fr-bullet, 7Fr-tee had less resistance force to the advancement of the stent delivery system. EUS-BD was technically successful in all ten pigs. Fistulous tract dilation was necessary in 100% (2/2), 75% (3/4), and 0% (0/4) of the pigs that underwent EUS-BD using 7.5Fr-bullet, 7Fr-bullet, and 7Fr-tee, respectively. There were no procedure-related complications. Our newly designed metal stent may be feasible and safe for EUS-BD, particularly when delivered by 7Fr-tee, because it eliminates the need for fistulous tract dilation.
Araujo, Pedro Henrique Xavier Nabuco de; Terra, Ricardo Mingarini; Santos, Thiago da Silva; Chate, Rodrigo Caruso; Paiva, Antonio Fernando Lins de; Pêgo-Fernandes, Paulo Manuel
2017-01-01
To evaluate the role of intrapleural positioning of a pleural catheter in early lung expansion and pleurodesis success in patients with recurrent malignant pleural effusion (RMPE). This was a retrospective study nested into a larger prospective cohort study including patients with RMPE recruited from a tertiary university teaching hospital between June of 2009 and September of 2014. The patients underwent pleural catheter insertion followed by bedside pleurodesis. Chest CT scans were performed twice: immediately before pleurodesis (iCT) and 30 days after pleurodesis (CT30). Catheter positioning was categorized based on iCT scans as posterolateral, anterior, fissural, and subpulmonary. We used the pleural volume on iCT scans to estimate early lung expansion and the difference between the pleural volumes on CT30 and iCT scans to evaluate radiological success of pleurodesis. Clinical pleurodesis success was defined as no need for any other pleural procedure. Of the 131 eligible patients from the original study, 85 were included in this nested study (64 women; mean age: 60.74 years). Catheter tip positioning was subpulmonary in 35 patients (41%), anterior in 23 (27%), posterolateral in 17 (20%), and fissural in 10 (12%). No significant differences were found among the groups regarding early lung expansion (median residual pleural cavity = 377 mL; interquartile range: 171-722 mL; p = 0.645), radiological success of pleurodesis (median volume = 33 mL; interquartile range: -225 to 257 mL; p = 0.923), and clinical success of pleurodesis (85.8%; p = 0.676). Our results suggest that the position of the tip of the pleural catheter influences neither early lung expansion nor bedside pleurodesis success in patients with RMPE. Avaliar o papel do posicionamento intrapleural do cateter pleural na expansão pulmonar precoce e no sucesso da pleurodese em pacientes com derrame pleural maligno recorrente (DPMR). Trata-se de um estudo retrospectivo aninhado em um estudo prospectivo de coorte maior com pacientes com DPMR recrutados em um hospital-escola universitário terciário entre junho de 2009 e setembro de 2014. Os pacientes foram submetidos a inserção de cateter pleural e, em seguida, pleurodese à beira do leito. A TC de tórax foi realizada duas vezes: imediatamente antes da pleurodese (TCi) e 30 dias após a pleurodese (TC30). Com base na TCi, a posição do cateter foi classificada em posterolateral, anterior, fissural e subpulmonar. Usamos o volume pleural na TCi para estimar a expansão pulmonar precoce e a diferença entre os volumes pleurais na TC30 e na TCi a fim de avaliar o sucesso radiológico da pleurodese. Considerou-se que a pleurodese teve êxito clínico quando não foi necessário realizar nenhum outro procedimento pleural. Dos 131 pacientes elegíveis do estudo original, 85 foram incluídos neste estudo aninhado (64 mulheres; média de idade: 60,74 anos). A posição da ponta do cateter foi subpulmonar em 35 pacientes (41%), anterior em 23 (27%), posterolateral em 17 (20%) e fissural em 10 (12%). Não houve diferenças significativas entre os grupos quanto à expansão pulmonar precoce (mediana da cavidade pleural residual = 377 ml; intervalo interquartil: 171-722 ml; p = 0,645), sucesso radiológico da pleurodese (mediana do volume = 33 ml; intervalo interquartil: -225 a 257 ml; p = 0,923) e sucesso clínico da pleurodese (85,8%; p = 0,676). Nossos resultados sugerem que a posição da ponta do cateter pleural não influencia nem a expansão pulmonar precoce nem o sucesso da pleurodese à beira do leito em pacientes com DPMR.
Figueiredo, Giovanna; Fiebig, Teresa; Kirschner, Stefanie; Nikoubashman, Omid; Kabelitz, Lisa; Othman, Ahmed; Nonn, Andrea; Kramer, Martin; Brockmann, Marc A.
2015-01-01
Background Repetitive administration of medication or contrast agents is frequently performed in mice. The introduction of vascular access mini-ports (VAMP) for mice allows long-term vascular catheterization, hereby eliminating the need for repeated vessel puncture. With catheter occlusion being the most commonly reported complication of chronic jugular vein catheterization, we tested whether digital subtraction angiography (DSA) can be utilized to evaluate VAMP patency in mice. Methods Twenty-three mice underwent catheterization of the jugular vein and subcutaneous implantation of a VAMP. The VAMP was flushed every second day with 50 μL of heparinized saline solution (25 IU/ml). DSA was performed during injection of 100 μL of an iodine based contrast agent using an industrial X-ray inspection system intraoperatively, as well as 7±2 and 14±2 days post implantation. Results DSA allowed localization of catheter tip position, to rule out dislocation, kinking or occlusion of a microcatheter, and to evaluate parent vessel patency. In addition, we observed different ante- and retrograde collateral flow patterns in case of jugular vein occlusion. More exactly, 30% of animals showed parent vessel occlusion after 7±2 days in our setting. At this time point, nevertheless, all VAMPs verified intravascular contrast administration. After 14±2 days, intravascular contrast injection was verified in 70% of the implanted VAMPs, whereas at this point of time 5 animals had died or were sacrificed and in 2 mice parent vessel occlusion hampered intravascular contrast injection. Notably, no occlusion of the catheter itself was observed. Conclusion From our observations we conclude DSA to be a fast and valuable minimally invasive tool for investigation of catheter and parent vessel patency and for anatomical studies of collateral blood flow in animals as small as mice. PMID:26098622
Pages, Justine; Hazera, Pascal; Mégarbane, Bruno; du Cheyron, Damien; Thuong, Marie; Dutheil, Jean-Jacques; Valette, Xavier; Fournel, François; Mermel, Leonard A; Mira, Jean-Paul; Daubin, Cédric; Parienti, Jean-Jacques
2016-09-01
Compare the effectiveness of different cutaneous antiseptics in reducing risk of catheter-related infection in intensive care unit (ICU) patients. We compared the risk of central venous catheter-related infection according to four-step (scrub, rinse, dry, and disinfect) alcoholic 5 % povidone-iodine (PVI-a, n = 1521), one-step (disinfect) alcoholic 2 % chlorhexidine (2 % CHX-a, n = 1116), four-step alcoholic <1 % chlorhexidine (<1 % CHX-a, n = 357), and four-step aqueous 10 % povidone-iodine (PVI, n = 368) antiseptics used for cutaneous disinfection and catheter care during the 3SITES multicenter randomized controlled trial. Within this cohort, we performed a quasi-experimental study (i.e., before-after) involving the four ICUs which switched from PVI-a to 2 % CHX-a. We used propensity score matching (PSM, n = 776) and inverse probability weighting treatment (IPWT, n = 1592). The end point was the incidence of catheter-related infection (CRI) defined as catheter-related bloodstream infection (CRBSI) or a positive catheter tip culture plus clinical sepsis on catheter removal. In the cohort analysis and compared with PVI-a, the incidence of CRI was lower with 2 % CHX-a [adjusted hazard ratio (aHR), 0.51; 95 % confidence interval (CI) (0.28-0.96), p = 0.037] and similar with <1 % CHX-a [aHR, 0.73; (0.36-1.48), p = 0.37] and PVI [aHR, 1.50; 95 % CI (0.85-2.64), p = 0.16] after controlling for potential confounders. In the quasi-experimental study and compared with PVI-a, the incidence of catheter-related infection was again lower with 2 % CHX-a after PSM [HR, 0.35; 95 % CI (0.15, 0.84), p = 0.02] and in the IPWT analysis [HR, 0.31; 95 % CI (0.14, 0.70), p = 0.005]. The incidence of CRBSI or adverse event was not significantly different between antiseptics in all analyses. In comparison with PVI-a, the use of 2 % CHX-a for cutaneous disinfection of the central venous catheter insertion site and maintenance catheter care was associated with a reduced risk of catheter infection, while the benefit of <1 % CHX-a was uncertain. NCT01479153.
Temporary quadriplegia following continuous thoracic paravertebral block.
Calenda, Emile; Baste, Jean Marc; Danielou, Eric; Michelin, Paul
2012-05-01
A case of temporary quadriplegia following a continuous thoracic paravertebral block in an adult patient scheduled for video-assisted thoracoscopy is presented. An 18-gauge Tuohy needle was inserted under direct vision by the surgeon but the tip of the catheter was not localized. Postoperatively, the patient developed temporary quadriplegia 90 minutes after the start of a continuous infusion of ropivacaine 0.2%. Imaging studies showed that the catheter was localized in the intrathecal space. Copyright © 2012 Elsevier Inc. All rights reserved.
[Persistent neonatal hypoglycaemia caused by arterial positioning of the umbilical venous catheter].
Peters, P A G; Brus, F; Noordam, C; Smorenburg, M K; van Setten, P A
2007-10-06
Two neonates, a girl born at 40 2/7 weeks weighing 4165 g and a boy born at 37 6/7 weeks weighing 4040 g, received umbilical venous catheters to help manage hypoglycaemia. The catheter was ineffective or only effective when high doses of glucose were used, due to what later appeared to be arterial positioning of the catheter. Both patients recovered without consequences. Persistent hypoglycaemia is a common problem in newborns and can cause severe neurological sequelae. A relatively uncommon cause is malpositioning of the umbilical catheter. Positioning in an artery leads to direct infusion of glucose into the pancreas, which causes hyperinsulinaemia and can lead to potentially dangerous nonketotic hypoglycaemia. Arterial positioning of the umbilical catheter should be ruled out at an early stage. Correct catheter positioning can be determined using careful inspection of the umbilical veins, radiological examination of the catheter position, blood gas analysis or vascular pulsation.
The Steerable Microcatheter: A New Device for Selective Catheterisation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soyama, Takeshi; Yoshida, Daisuke; Sakuhara, Yusuke, E-mail: yusaku@med.hokudai.ac.jp
The steerable microcatheter (SwiftNINJA, Sumitomo Bakelite, Tokyo, Japan), which has a remote-controlled flexible tip manipulated using a dial in the handgrip, was recently developed and delivered to the market. This device enables the user to change the angle of the microcatheter tip manually, and potentially makes selective catheterisation easier. We evaluated its unique characteristics and utility in selective catheterisation and coil embolization. This article describes: (1) the advantages of this device in catheterisations involving acute angle branches, and (2) a new technique of compact coil packing with the use of intentional folding by the bendable tip of the catheter.
... or blood pooling where the catheter is inserted Blood clot that goes to arteries in your leg, heart, ... cooking oils Cholesterol and lifestyle Controlling your high blood pressure Dietary fats explained Fast food tips Heart attack - discharge Heart disease - risk factors ...
Belch, A; Rubinos, C; Barnes, D C; Nelissen, P
2017-02-01
To report the short- and long-term complications and clinical outcomes of a cohort of dogs managed for gastric dilatation-volvulus using a modified right-sided tube gastropexy technique. Retrospective case series. Of 31 dogs treated, 29 (93·5%) had an excellent short-term outcome, and gastric dilatation-volvulus did not recur in any dog. Twenty-six dogs (84%) were initially fed via the gastrostomy tube postoperatively; three (9·7%) suffered a major complication including septic peritonitis (n=1), and premature tube removal (n=2). Fourteen dogs (45·1%) had minor complications including mild, self-limiting discharge from the stoma site in 13. Modified tube gastropexy using a mushroom-tipped silicone catheter is an effective and safe surgical method for the management of gastric dilatation-volvulus. The gastrostomy tube allowed early enteral feeding and easy administration of medications, including gastroprotectants. © 2017 British Small Animal Veterinary Association.
Wadhwa, Rishi K; Shaya, Mark R; Nanda, Anil
2006-02-01
The use of intrathecal morphine has been effective with few complications for chronic intractable pain of both benign and malignant origins. A rare but serious problem that exists is the formation of an inflammatory mass at the catheter tip of the pain pump. We report the case of a 67-year-old female patient with failed back syndrome who presented with sensory complaints and back pain. Magnetic resonance imaging revealed impingement on the thoracic cord by a mass. The mass was originally thought to be a spinal cord tumor; however, operation and chemical analysis of the mass showed that it was a bupivacaine precipitate at the tip of the catheter of the pain pump. This is the first such case, to our knowledge, of a bupivacaine precipitate mimicking a spinal cord tumor.
Riga, Celia V; Bicknell, Colin D; Hamady, Mohamad; Cheshire, Nicholas
2012-10-01
To attempt to quantify the effect of varying degrees of iliac tortuosity on maneuverability and "torquability" of endovascular catheters in the visceral segment, comparing conventional and robotic cannulation techniques. In a fenestrated endograft within a pulsatile phantom, 10 experienced operators cannulated the renal arteries via three different access vessels of varying iliac tortuosity with the use of conventional and robotic techniques. All procedures were performed in the angiography suite and recorded for blinded video assessment for quantitative (time, catheter-tip movements) and qualitative metrics (operator performance scores). In total, 120 cannulations were observed. With increasing iliac tortuosity, median time and number of catheter movements required for renal cannulation with conventional techniques increased in stepwise fashion for mild, moderate, and severe iliac tortuosity (times, 7.6 min [interquartile range (IQR), 4.6-9.3 min] vs 6.9 min [4.2-11.4 min] vs 17.7 min [13.3-22.6 min], respectively; movements, 184 [IQR, 110-351] vs 251 [207-395] vs 569 [409-616], respectively). Median renal cannulation times were significantly reduced with the use of the robotic system irrespective of mild, moderate, or severe tortuosity (times, 1.4 min [IQR, 1.1-1.9 min] vs 3 min [2.3-3.3 min] vs 2.8 min [1.5-3.9 min], respectively; movements, 19 [IQR, 14-27] vs 46 [43-58] vs 45 [40-66], respectively; P < .005). Overall operator performance scores improved significantly with the use of the robotic system irrespective of iliac tortuosity severity. In cases of moderate to severe iliac tortuosity, conventional catheter manipulation and control becomes an issue. The improvement in positional control and predictability seen with advanced catheter designs may be amplified in cases of severe iliac tortuosity. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.
Sensor-Based Electromagnetic Navigation (Mediguide®): How Accurate Is It? A Phantom Model Study.
Bourier, Felix; Reents, Tilko; Ammar-Busch, Sonia; Buiatti, Alessandra; Grebmer, Christian; Telishevska, Marta; Brkic, Amir; Semmler, Verena; Lennerz, Carsten; Kaess, Bernhard; Kottmaier, Marc; Kolb, Christof; Deisenhofer, Isabel; Hessling, Gabriele
2015-10-01
Data about localization reproducibility as well as spatial and visual accuracy of the new MediGuide® sensor-based electroanatomic navigation technology are scarce. We therefore sought to quantify these parameters based on phantom experiments. A realistic heart phantom was generated in a 3D-Printer. A CT scan was performed on the phantom. The phantom itself served as ground-truth reference to ensure exact and reproducible catheter placement. A MediGuide® catheter was repeatedly tagged at selected positions to assess accuracy of point localization. The catheter was also used to acquire a MediGuide®-scaled geometry in the EnSite Velocity® electroanatomic mapping system. The acquired geometries (MediGuide®-scaled and EnSite Velocity®-scaled) were compared to a CT segmentation of the phantom to quantify concordance. Distances between landmarks were measured in the EnSite Velocity®- and MediGuide®-scaled geometry and the CT dataset for Bland-Altman comparison. The visualization of virtual MediGuide® catheter tips was compared to their corresponding representation on fluoroscopic cine-loops. Point localization accuracy was 0.5 ± 0.3 mm for MediGuide® and 1.4 ± 0.7 mm for EnSite Velocity®. The 3D accuracy of the geometries was 1.1 ± 1.4 mm (MediGuide®-scaled) and 3.2 ± 1.6 mm (not MediGuide®-scaled). The offset between virtual MediGuide® catheter visualization and catheter representation on corresponding fluoroscopic cine-loops was 0.4 ± 0.1 mm. The MediGuide® system shows a very high level of accuracy regarding localization reproducibility as well as spatial and visual accuracy, which can be ascribed to the magnetic field localization technology. The observed offsets between the geometry visualization and the real phantom are below a clinically relevant threshold. © 2015 Wiley Periodicals, Inc.
Abi-Nader, Khalil N; Mehta, Vedanta; Shaw, S W Steven; Bellamy, Tom; Smith, Neil; Millross, Laura; Laverick, Beth; Filippi, Elisa; Boyd, Michael; Peebles, Donald M; David, Anna L
2011-01-01
Remote telemetric monitoring of fetal haemodynamics in pregnant sheep would allow unrestricted animal movement, minimize suffering and distress, and improve animal welfare, while enhancing the quality of data collected. This may also be useful in clinical practice following fetal surgery. Using an open fetal surgical technique at approximately two-thirds of gestation, we implanted the catheter of a D70-PCTP haemodynamic telemetric device (Data Sciences International, Tilburg, The Netherlands) into the carotid artery of the fetal sheep (n = 4). The attached transmitter was secured to the posterior aspect of the maternal anterior abdominal wall. Two receivers, with a range of 1 m each, were sited in an 11 m² sheep enclosure to maximize animal freedom while allowing continuous monitoring of the ewe. The receivers were connected by cable to a nearby computer. In the first two procedures, both fetuses died eight and 12 days after surgery, and the catheter tip was observed to be lying in the bicarotid trunk. In the next two procedures the catheter tip was threaded further upstream from the insertion point, in an attempt to reach the fetal aorta, and both fetuses survived until the scheduled postmortem examination at the end of pregnancy. After catheter implantation, fetal blood pressure (BP) and heart rate (HR) were successfully recorded continuously for seven days and then hourly per day for a further three weeks. The fetal BP and HR values were in the normal range for healthy sheep fetuses.
van 't Veer, Marcel; Adjedj, Julien; Wijnbergen, Inge; Tóth, Gabor G; Rutten, Marcel C M; Barbato, Emanuele; van Nunen, Lokien X; Pijls, Nico H J; De Bruyne, Bernard
2016-08-20
The aim of this study is to validate a novel monorail infusion catheter for thermodilution-based quantitative coronary flow measurements. Based on the principles of thermodilution, volumetric coronary flow can be determined from the flow rate of a continuous saline infusion, the temperature of saline when it enters the coronary artery, and the temperature of the blood mixed with the saline in the distal part of the coronary artery. In an in vitro set-up of the systemic and coronary circulation at body temperature, coronary flow values were varied from 50-300 ml/min in steps of 50 ml/min. At each coronary flow value, thermodilution-based measurements were performed at infusion rates of 15, 20, and 30 ml/min. Temperatures and pressures were simultaneously measured with a pressure/temperature sensor-tipped guidewire. Agreement of the calculated flow and the measured flow as well as repeatability were assessed. A total of five catheters were tested, with a total of 180 measurements. A strong correlation (ρ=0.976, p<0.0001) and a difference of -6.5±15.5 ml/min were found between measured and calculated flow. The difference between two repeated measures was 0.2%±8.0%. This novel infusion catheter used in combination with a pressure/temperature sensor-tipped guidewire allows accurate and repeatable absolute coronary flow measurements. This opens a window to a better understanding of the coronary microcirculation.
Short-term infection in cuffed versus noncuffed small bore central catheters: a randomized trial.
Trerotola, Scott O; Patel, Aalpen A; Shlansky-Goldberg, Richard D; Solomon, Jeffrey A; Mondschein, Jeffrey I; Stavropoulos, S William; Soulen, Michael C; Itkin, Maxim; Chittams, Jesse
2010-02-01
To determine if a polyester cuff offered benefit in jugular small-bore central catheters (SBCCs). Eighty-four patients were randomly assigned to receive a 5-F single- or 6-F dual-lumen SBCC with (n = 42) or without (n = 42) a polyester cuff. Follow-up was performed at 2 weeks, 1 month, and 3 months or at catheter removal, whichever came first. At scheduled follow-up, catheter function, patient satisfaction, and infection were determined. At catheter removal, tip culture was performed to determine colonization and jugular vein patency was determined with ultrasonography (US). The overall infection rate was 0.4 per 1,000 catheter days. There was one clinical infection (noncuffed catheter). Colonization occurred in two noncuffed catheters and one cuffed catheter. There was one catheter dislodgment in the noncuffed group and none in the cuffed group. Cuffed catheters were no more difficult to insert but took slightly longer to remove (6 minutes +/- 4.7 vs 5 minutes +/- 3, P = .39) and often required local anesthesia for removal, whereas noncuffed catheters did not (41% vs 0%, P = .001). Partial (two cuffed, 0 noncuffed) or complete (two cuffed, one noncuffed) jugular thrombosis was seen on five of 58 completion US studies (8.6%). A polyester cuff on a SBCC confers no significant benefit in short-term colonization rates. Infection in SBCCs is uncommon. Despite their small diameters, SBCCs can result in jugular thrombosis, an important consideration in any patient requiring long-term venous access. Copyright (c) 2010 SIR. Published by Elsevier Inc. All rights reserved.
Comparison of air-charged and water-filled urodynamic pressure measurement catheters.
Cooper, M A; Fletter, P C; Zaszczurynski, P J; Damaser, M S
2011-03-01
Catheter systems are utilized to measure pressure for diagnosis of voiding dysfunction. In a clinical setting, patient movement and urodynamic pumps introduce hydrostatic and motion artifacts into measurements. Therefore, complete characterization of a catheter system includes its response to artifacts as well its frequency response. The objective of this study was to compare the response of two disposable clinical catheter systems: water-filled and air-charged, to controlled pressure signals to assess their similarities and differences in pressure transduction. We characterized frequency response using a transient step test, which exposed the catheters to a sudden change in pressure; and a sinusoidal frequency sweep test, which exposed the catheters to a sinusoidal pressure wave from 1 to 30 Hz. The response of the catheters to motion artifacts was tested using a vortex and the response to hydrostatic pressure changes was tested by moving the catheter tips to calibrated heights. Water-filled catheters acted as an underdamped system, resonating at 10.13 ± 1.03 Hz and attenuating signals at frequencies higher than 19 Hz. They demonstrated significant motion and hydrostatic artifacts. Air-charged catheters acted as an overdamped system and attenuated signals at frequencies higher than 3.02 ± 0.13 Hz. They demonstrated significantly less motion and hydrostatic artifacts than water-filled catheters. The transient step and frequency sweep tests gave comparable results. Air-charged and water-filled catheters respond to pressure changes in dramatically different ways. Knowledge of the characteristics of the pressure-measuring system is essential to finding the best match for a specific application. Copyright © 2011 Wiley-Liss, Inc.
Contact force with magnetic-guided catheter ablation.
Bessière, Francis; Zikry, Christopher; Rivard, Lena; Dyrda, Katia; Khairy, Paul
2018-05-01
Achieving adequate catheter tip-tissue contact is essential for delivering robust radiofrequency (RF) ablation lesions. We measured the contact force generated by a remote magnetic-guided catheter navigation system. A plexiglass model with an integrated scale was fashioned to mimic transvenous and retrograde access to sites in the right atrium and right and left ventricles. An 8 Fr RF ablation catheter was steered by remote magnetic guidance at fields of 0.08 and 0.10 T, with and without a long sheath positioned at the entrance of the chamber. Ten contact force readings were taken at each setting, with the scale recalibrated prior to each measurement. Generalized estimating equations were used to compare contact force measurements while adjusting for the non-independent data structure. A total of 240 contact force measurements were taken. Without a long sheath, contact forces with magnetic fields of 0.10 T (n = 60) and 0.08 T (n = 60) were similar (6.1 ± 1.4 g vs. 6.0 ± 1.3 g, P = 0.089). Contact forces were not significantly different with simulated transvenous (n = 80) and retrograde aortic (n = 40) approaches (6.2 ± 1.4 g vs. 5.7 ± 1.2 g, P = 0.132). The contact force increased substantially with a long sheath (P < 0.001) and was significantly higher with 0.10 T (n = 60) vs. 0.08 T (n = 60) fields (20.4 ± 0.6 g vs. 18.0 ± 0.5 g, P < 0.001). Magnetic fields of 0.08 and 0.10 T provide stable catheter contact forces, as reflected by the small variability between measurements. The average contact force is approximately 6 g without a sheath and increases to 20 g with a long sheath positioned at the entrance of the chamber of interest.
Effect of Coronary Anatomy and Hydrostatic Pressure on Intracoronary Indices of Stenosis Severity.
Härle, Tobias; Luz, Mareike; Meyer, Sven; Kronberg, Kay; Nickau, Britta; Escaned, Javier; Davies, Justin; Elsässer, Albrecht
2017-04-24
The authors sought to analyze height differences within the coronary artery tree in patients in a supine position and to quantify the impact of hydrostatic pressure on intracoronary pressure measurements in vitro. Although pressure equalization of the pressure sensor and the systemic pressure at the catheter tip is mandatory in intracoronary pressure measurements, subsequent measurements may be influenced by hydrostatic pressure related to the coronary anatomy in the supine position. Outlining and quantifying this phenomenon is important to interpret routine and pullback pressure measurements within the coronary tree. Coronary anatomy was analyzed in computed tomography angiographies of 70 patients to calculate height differences between the catheter tip and different coronary segments in the supine position. Using a dynamic pressure simulator, the effect of the expected hydrostatic pressure resulting from such height differences on indices stenosis severity was assessed. In all patients, the left anterior and right posterior descending arteries are the highest points of the coronary tree with a mean height difference of -4.9 ± 1.6 cm and -3.8 ± 1.0 cm; whereas the circumflex artery and right posterolateral branches are the lowest points, with mean height differences of 3.9 ± 0.9 cm and 2.6 ± 1.6 cm compared with the according ostium. In vitro measurements demonstrated a correlation of the absolute pressure differences with height differences (r = 0.993; p < 0.0001) and the slope was 0.77 mm Hg/cm. The Pd/Pa ratio and instantaneous wave-free ratio correlated also with the height difference (fractional flow reserve r = 0.98; p < 0.0001; instantaneous wave-free ratio r = 0.97; p < 0.0001), but both were influenced by the systemic pressure level. Hydrostatic pressure variations resulting from normal coronary anatomy in a supine position influence intracoronary pressure measurements and may affect their interpretation during stenosis severity assessment. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Development of a force-reflecting robotic platform for cardiac catheter navigation.
Park, Jun Woo; Choi, Jaesoon; Pak, Hui-Nam; Song, Seung Joon; Lee, Jung Chan; Park, Yongdoo; Shin, Seung Min; Sun, Kyung
2010-11-01
Electrophysiological catheters are used for both diagnostics and clinical intervention. To facilitate more accurate and precise catheter navigation, robotic cardiac catheter navigation systems have been developed and commercialized. The authors have developed a novel force-reflecting robotic catheter navigation system. The system is a network-based master-slave configuration having a 3-degree of freedom robotic manipulator for operation with a conventional cardiac ablation catheter. The master manipulator implements a haptic user interface device with force feedback using a force or torque signal either measured with a sensor or estimated from the motor current signal in the slave manipulator. The slave manipulator is a robotic motion control platform on which the cardiac ablation catheter is mounted. The catheter motions-forward and backward movements, rolling, and catheter tip bending-are controlled by electromechanical actuators located in the slave manipulator. The control software runs on a real-time operating system-based workstation and implements the master/slave motion synchronization control of the robot system. The master/slave motion synchronization response was assessed with step, sinusoidal, and arbitrarily varying motion commands, and showed satisfactory performance with insignificant steady-state motion error. The current system successfully implemented the motion control function and will undergo safety and performance evaluation by means of animal experiments. Further studies on the force feedback control algorithm and on an active motion catheter with an embedded actuation mechanism are underway. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Means and methods for cytometric therapies
Gillies, George T.; Fillmore, Helen; Broaddus, William C.; Evans, III, Boyd M.; Allison, Stephen W.
2013-03-26
A functionalized tip is incorporated into catheters for the cytometric delivery of cells into the brain and other body parts. For use in the brain, the tip forms part of a neurosurgical probe having a proximal end and a distal end. In addition to the functionalized tip, the probe has at least one cell slurry delivery lumen and a plurality of optical fibers configured along the probe, terminating in the tip to provide the photo-optical capability needed to monitor the viability and physiological behavior of the grafted cells as well as certain characteristics of the cellular environment. Details are also presented of the use of a neurocatheter having a cytometric tip of the type disclosed in the invention, as employed within the context of a feedback and control system for regulating the number of cells delivered to the brain of a patient.
Gurjarpadhye, Abhijit Achyut; DeWitt, Matthew R; Xu, Yong; Wang, Ge; Rylander, Marissa Nichole; Rylander, Christopher G
2015-07-01
Lumen endothelialization of bioengineered vascular scaffolds is essential to maintain small-diameter graft patency and prevent thrombosis postimplantation. Unfortunately, nondestructive imaging methods to visualize this dynamic process are lacking, thus slowing development and clinical translation of these potential tissue-engineering approaches. To meet this need, a fluorescence imaging system utilizing a commercial optical coherence tomography (OCT) catheter was designed to visualize graft endothelialization. C7 DragonFly™ intravascular OCT catheter was used as a channel for delivery and collection of excitation and emission spectra. Poly-dl-lactide (PDLLA) electrospun scaffolds were seeded with endothelial cells (ECs). Seeded cells were exposed to Calcein AM before imaging, causing the living cells to emit green fluorescence in response to blue laser. By positioning the catheter tip precisely over a specimen using high-fidelity electromechanical components, small regions of the specimen were excited selectively. The resulting fluorescence intensities were mapped on a two-dimensional digital grid to generate spatial distribution of fluorophores at single-cell-level resolution. Fluorescence imaging of endothelialization on glass and PDLLA scaffolds was performed using the OCT catheter-based imaging system as well as with a commercial fluorescence microscope. Cell coverage area was calculated for both image sets for quantitative comparison of imaging techniques. Tubular PDLLA scaffolds were maintained in a bioreactor on seeding with ECs, and endothelialization was monitored over 5 days using the OCT catheter-based imaging system. No significant difference was observed in images obtained using our imaging system to those acquired with the fluorescence microscope. Cell area coverage calculated using the images yielded similar values. Nondestructive imaging of endothelialization on tubular scaffolds showed cell proliferation with cell coverage area increasing from 15 ± 4% to 89 ± 6% over 5 days. In this study, we showed the capability of an OCT catheter-based imaging system to obtain single-cell resolution and to quantify endothelialization in tubular electrospun scaffolds. We also compared the resulting images with traditional microscopy, showing high fidelity in image capability. This imaging system, used in conjunction with OCT, could potentially be a powerful tool for in vitro optimization of scaffold cellularization, ensuring long-term graft patency postimplantation.
Gill, T; Barua, N U; Woolley, M; Bienemann, A S; Johnson, D E; S O'Sullivan; Murray, G; Fennelly, C; Lewis, O; Irving, C; Wyatt, M J; Moore, P; Gill, S S
2013-09-30
The optimisation of convection-enhanced drug delivery (CED) to the brain is fundamentally reliant on minimising drug reflux. The aim of this study was to evaluate the performance of a novel reflux-resistant CED catheter incorporating a recessed-step and to compare its performance to previously described stepped catheters. The in vitro performance of the recessed-step catheter was compared to a conventional "one-step" catheter with a single transition in outer diameter (OD) at the catheter tip, and a "two-step" design comprising two distal transitions in OD. The volumes of distribution and reflux were compared by performing infusions of Trypan blue into agarose gels. The in vivo performance of the recessed-step catheter was then analysed in a large animal model by performing infusions of 0.2% Gadolinium-DTPA in Large White/Landrace pigs. The recessed-step catheter demonstrated significantly higher volumes of distribution than the one-step and two-step catheters (p=0.0001, one-way ANOVA). No reflux was detected until more than 100 ul had been delivered via the recessed-step catheter, whilst reflux was detected after infusion of only 25 ul via the 2 non-recessed catheters. The recessed-step design also showed superior reflux resistance to a conventational one-step catheter in vivo. Reflux-free infusions were achieved in the thalamus, putamen and white matter at a maximum infusion rate of 5 ul/min using the recessed-step design. The novel recessed-step catheter described in this study shows significant potential for the achievement of predictable high volume, high flow rate infusions whilst minimising the risk of reflux. Copyright © 2013 Elsevier B.V. All rights reserved.
... on the toilet. You may use clean disposable gloves, if you prefer not to use your bare hands. The gloves do not need to be sterile, unless your ... Jelly or other gel to the tip and top 2 inches (5 centimeters) of the catheter. (Some ...
A new technique of laparoscopic cholangiography.
Hagan, K D; Rosemurgy, A S; Albrink, M H; Carey, L C
1992-04-01
With the advent and rapid proliferation of laparoscopic cholecystectomy, numerous techniques and "tips" have been described. Intraoperative cholangiography during laparoscopic cholecystectomy can be tedious, frustrating, and time consuming. Described herein is a technique of intraoperative cholangiography during laparoscopic cholecystectomy which has proven to be easy, fast, and succinct. This method utilizes a rigid cholangiogram catheter which is placed into the peritoneal cavity through a small additional puncture site. This catheter is easily inserted into the cystic duct by extracorporeal manipulation. We suggest this method to surgeons who have shared our prior frustration with intraoperative cholangiography.
Hansky, Bert; Vogt, Juergen; Gueldner, Holger; Schulte-Eistrup, Sebastian; Lamp, Barbara; Heintze, Johannes; Horstkotte, Dieter; Koerfer, Reiner
2007-01-01
Securing transvenous left ventricular (LV) pacing leads without an active fixation mechanism in proximal coronary vein (CV) segments is usually challenging and frequently impossible. We investigated how active fixation leads can be safely implanted in this location, how to avoid perforating the free wall of the CV, and how to recognize and respond to perforations. In five patients with no alternative to LV pacing from proximal CV segments, 4 Fr SelectSecure (Medtronic, Minneapolis, MN, USA) leads, which have a fixed helix, were implanted through a modified 6 Fr guide catheter with a pre-shaped tip (Launcher, Medtronic). Active fixation leads were successfully implanted in proximal CVs in five patients. There were no complications. Acute and chronic pacing thresholds were comparable to those of conventional CV leads. The pre-shaped guide catheter tip remains in close proximity to the myocardial aspect of the CV, directing the lead helix toward a safe implantation site. If only proximal CV pacing sites are available, 4 Fr SelectSecure leads can be safely implanted through a modified Launcher guide catheter, avoiding more invasive implantation techniques. Other than venous stenting or implantation of leads with retractable tines, SelectSecure leads are expected to remain extractable.
Carpenter, Thomas M.; Rashid, M. Wasequr; Ghovanloo, Maysam; Cowell, David M. J.; Freear, Steven; Degertekin, F. Levent
2016-01-01
In real-time catheter based 3D ultrasound imaging applications, gathering data from the transducer arrays is difficult as there is a restriction on cable count due to the diameter of the catheter. Although area and power hungry multiplexing circuits integrated at the catheter tip are used in some applications, these are unsuitable for use in small sized catheters for applications like intracardiac imaging. Furthermore, the length requirement for catheters and limited power available to on-chip cable drivers leads to limited signal strength at the receiver end. In this paper an alternative approach using Analog Time Division Multiplexing (TDM) is presented which addresses the cable restrictions of ultrasound catheters. A novel digital demultiplexing technique is also described which allows for a reduction in the number of analog signal processing stages required. The TDM and digital demultiplexing schemes are demonstrated for an intracardiac imaging system that would operate in the 4 MHz to 11 MHz range. A TDM integrated circuit (IC) with 8:1 multiplexer is interfaced with a fast ADC through a micro-coaxial catheter cable bundle, and processed with an FPGA RTL simulation. Input signals to the TDM IC are recovered with −40 dB crosstalk between channels on the same micro-coax, showing the feasibility of this system for ultrasound imaging applications. PMID:27116738
Herial, Nabeel A; Khan, Asif A; Sherr, Gregory T; Qureshi, Mushtaq H; Suri, M Fareed K; Qureshi, Adnan I
2015-09-01
The US Food and Drug Administration recently approved a detachable-tip microcatheter, the Apollo microcatheter (eV3, Inc, Irvine, California), to prevent catheter entrapment during embolization of brain arteriovenous malformations (AVMs) using liquid embolic systems. To report technical aspects and clinical results of cerebral embolizations with the Apollo microcatheter in 7 embolizations in 3 adult patients. A 62-year-old man presented with an AVM in the parieto-occipital region measuring 3.6 × 1.6 cm with major cortical feeders from the right middle cerebral artery (MCA) and minor contribution from the distal right anterior cerebral artery. Two pedicles originating from the MCA were embolized. A 48-year-old woman presented with a left frontal AVM measuring 3.3 × 1.8 cm with arterial feeders from the left MCA, left middle meningeal artery, and contralateral anterior cerebral artery. Three pedicles originating from the left MCA were embolized. A 76-year-old man presented with an arteriovenous fistula with multiple fistulous connections and feeders from both vertebral and occipital arteries and the left posterior cerebral artery draining into the left transverse, torcula, and left sigmoid sinus. Two major occipital artery feeders were embolized. Seven Apollo microcatheters were used with the Onyx 18 liquid embolic system. The length of the detachable tip was 15 mm in 2 and 30 mm in 5 embolizations. The mean microcatheter in-position time within the pedicle was 20 minutes. Detachment of tip occurred in 3 instances. No limitations in accessing target arterial feeders and safe tip disengagement were noted despite prolonged injection times. Our initial experience supports the feasibility, safety, and effectiveness of detachable-tip microcatheters in treating brain AVMs and arteriovenous fistulas.
[Coronary angioplasty with the Monorail system via 6 French diagnostic catheters].
Villavicencio, R; González, H; López, J; Zavala, E; Ban Hayashi, E B; Gaspar, J; Gil, M; Martínez Ríos, M A
1994-01-01
We studied the use of "Monorail" system with Express (Scimed) balloon catheters for coronary angioplasty through 6 French (F) "high-flow" diagnostic catheters (Novoste, USCI). Prospectively, from July 1992 to January 1993, angioplasty of 31 lesions in 24 patients was attempted (1.3 lesions/procedure). Twenty procedures were of a single lesion and four were multi-vessel angioplasty. Fourteen lesions were in the left anterior descending or in its branches, 10 in the left circumflex or in its branches, 6 in the right coronary artery, and one in the distal anastomosis of an internal mammary artery graft. Thirteen lesions (42%) were type A, 17 (55%) type B and one (3%) type C. Balloon sizes varied between 2.0 and 3.5 mm. Twenty-nine lesions could be successfully dilated (93.5%); two cases were unsuccessful due to an acute occlusion in one and residual stenosis of more than 50% in the other. For only one case, another balloon catheter different from the "Monorail" system was necessary to complete a multi-vessel angioplasty. Coronary visualization and manipulation of the balloon through the tip of the diagnostic catheter were satisfactory in all cases, except with the 3.5 mm balloon catheter. Coronary angioplasty with "Monorail" system balloon catheters through 6 F "high-flow" diagnostic catheters is feasible and provides a high success rate in simple and moderately complex selected lesions, including multivessel angioplasty with advantages of smaller artery punction and the feasibility of performing coronary angioplasty with the same catheter used for diagnostic angiography.
Grover, Davinder S; Fellman, Ronald L
2016-06-01
To describe a novel technique for thermally marking the tip of a suture, in preparation for a gonioscopy-assisted transluminal trabeculotomy. One patient was used as an example for this technique. Technique report. The authors introduce a modification of a novel surgical procedure (GATT) in which a suture is marked and thermally blunted allowing a proper visualization while performing an ab interno, minimally invasive, circumferential 360-degree suture trabeculotomy. The authors have previously reported on the GATT surgery with the use of an illuminated microcatheter, which allowed for visualization of the tip of the catheter as it circumnavigated Schlemm canal. This modification allows for similar visualization of the tip of the suture, however, is much more cost-effective while still maintaining similar safety.
Motion-adapted catheter navigation with real-time instantiation and improved visualisation
Kwok, Ka-Wai; Wang, Lichao; Riga, Celia; Bicknell, Colin; Cheshire, Nicholas; Yang, Guang-Zhong
2014-01-01
The improvements to catheter manipulation by the use of robot-assisted catheter navigation for endovascular procedures include increased precision, stability of motion and operator comfort. However, navigation through the vasculature under fluoroscopic guidance is still challenging, mostly due to physiological motion and when tortuous vessels are involved. In this paper, we propose a motion-adaptive catheter navigation scheme based on shape modelling to compensate for these dynamic effects, permitting predictive and dynamic navigations. This allows for timed manipulations synchronised with the vascular motion. The technical contribution of the paper includes the following two aspects. Firstly, a dynamic shape modelling and real-time instantiation scheme based on sparse data obtained intra-operatively is proposed for improved visualisation of the 3D vasculature during endovascular intervention. Secondly, a reconstructed frontal view from the catheter tip using the derived dynamic model is used as an interventional aid to user guidance. To demonstrate the practical value of the proposed framework, a simulated aortic branch cannulation procedure is used with detailed user validation to demonstrate the improvement in navigation quality and efficiency. PMID:24744817
Respiratory motion influence on catheter contact force during radio frequency ablation procedures
NASA Astrophysics Data System (ADS)
Koch, Martin; Brost, Alexander; Hornegger, Joachim; Strobel, Norbert
2013-03-01
Minimally invasive catheter ablation is a common treatment option for atrial fibrillation. A common treatment strategy is pulmonary vein isolation. In this case, individual ablation points need to be placed around the ostia of the pulmonary veins attached to the left atrium to generate transmural lesions and thereby block electric signals. To achieve a durable transmural lesion, the tip of the catheter has to be stable with a sufficient tissue contact during radio-frequency ablation. Besides the steerable interface operated by the physician, the movement of the catheter is also influenced by the heart and breathing motion - particularly during ablation. In this paper we investigate the influence of breathing motion on different areas of the endocardium during radio frequency ablation. To this end, we analyze the frequency spectrum of the continuous catheter contact force to identify areas with increased breathing motion using a classification method. This approach has been applied to clinical patient data acquired during three pulmonary vein isolation procedures. Initial findings show that motion due to respiration is more pronounced at the roof and around the right pulmonary veins.
Belohlavek, Marek; Katayama, Minako; Zarbatany, David; Fortuin, F David; Fatemi, Mostafa; Nenadic, Ivan Z; McMahon, Eileen M
2014-07-01
Catheters are increasingly used therapeutically and investigatively. With complex usage comes a need for more accurate intracardiac localization than traditional guidance can provide. An injection catheter navigated by ultrasound was designed and then tested in an open-chest model of acute ischemia in eight pigs. The catheter is made "acoustically active" by a piezo-electric crystal near its tip, electronically controlled, vibrating in the audio frequency range and uniquely identifiable using pulsed-wave Doppler. Another "target" crystal was sutured to the epicardium within the ischemic region. Sonomicrometry was used to measure distances between the two crystals and then compared with measurements from 2-D echocardiographic images. Complete data were obtained from seven pigs, and the correlation between sonomicrometry and ultrasound measurements was excellent (p < 0.0001, ρ = 0.9820), as was the intraclass correlation coefficient (0.96) between two observers. These initial experimental results suggest high accuracy of ultrasound navigation of the acoustically active catheter prototype located inside the beating left ventricle. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Perk, Gila; Lang, Roberto M; Garcia-Fernandez, Miguel Angel; Lodato, Joe; Sugeng, Lissa; Lopez, John; Knight, Brad P; Messika-Zeitoun, David; Shah, Sanjiv; Slater, James; Brochet, Eric; Varkey, Mathew; Hijazi, Ziyad; Marino, Nino; Ruiz, Carlos; Kronzon, Itzhak
2009-08-01
Real-time three-dimensional (RT3D) echocardiography is a recently developed technique that is being increasingly used in echocardiography laboratories. Over the past several years, improvements in transducer technologies have allowed development of a full matrix-array transducer that allows acquisition of pyramidal-shaped data sets. These data sets can be processed online and offline to allow accurate evaluation of cardiac structures, volumes, and mass. More recently, a transesophageal transducer with RT3D capabilities has been developed. This allows acquisition of high-quality RT3D images on transesophageal echocardiography (TEE). Percutaneous catheter-based procedures have gained growing acceptance in the cardiac procedural armamentarium. Advances in technology and technical skills allow increasingly complex procedures to be performed using a catheter-based approach, thus obviating the need for open-heart surgery. The authors used RT3D TEE to guide 72 catheter-based cardiac interventions. The procedures included the occlusion of atrial septal defects or patent foramen ovales (n=25), percutaneous mitral valve repair (e-valve clipping; n=3), mitral balloon valvuloplasty for mitral stenosis (n=10), left atrial appendage obliteration (n=11), left atrial or pulmonary vein ablation for atrial fibrillation (n=5), percutaneous closures of prosthetic valve dehiscence (n=10), percutaneous aortic valve replacement (n=6), and percutaneous closures of ventricular septal defects (n=2). In this review, the authors describe their experience with this technique, the added value over multiplanar two-dimensional TEE, and the pitfalls that were encountered. The main advantages found for the use RT3D TEE during catheter-based interventions were (1) the ability to visualize the entire lengths of intracardiac catheters, including the tips of all catheters and the balloons or devices they carry, along with a clear depiction of their positions in relation to other cardiac structures, and (2) the ability to ability to demonstrate certain structures in an "en face" view, which is not offered by any other currently available real-time imaging technique, enabling appreciation of the exact nature of the lesion that is undergoing intervention. RT3D TEE is a powerful new imaging tool that may become the technique of choice and the standard of care for guidance of selected percutaneous catheter-based procedures.
Malinova, Vesna; Stockhammer, Florian; Atangana, Etienne Ndzie; Mielke, Dorothee; Rohde, Veit
2014-06-01
The optimal management of spontaneous intracerebral hemorrhage (ICH), especially if deep-seated, remains a matter of discussion. Lysis of the blood clot applying recombinant tissue-type plasminogen activator (rtPA) by an intrahematomal catheter is a minimally invasive treatment option, currently being under investigation in a randomized trial. The center position of the catheter in the hematoma is believed to be crucial for an optimal clot lysis. To achieve this objective, frame-based stereotaxy and frameless stereotaxy with guidance of an articulated arm were used. Recently, a preregistered stylet for direct navigation, alleviating the need of guidance, became available. In this study, we evaluated the relative error (RE) describing the deviation of the catheter from the ideal center position in the clot and compared the accuracy of catheter placement using frameless stereotaxy or the novel preregistered stylet. The intrahematomal catheter position was evaluated in three dimensions in 89 patients with spontaneous supratentorial ICH. Frameless stereotaxy with guidance of an articulated arm was performed in 50 patients. The preregistered stylet was used in 39 patients. The catheter position was evaluated using a RE calculating the distance perpendicular to the center of the catheter in relation to the hematoma's diameter. The mean hematoma volume was 51.4 ml. Forty-four out of 89 hematomas were deep-seated. Intraventricular blood was found in 59 patients. The RE of the catheter position was lower in the stylet group in comparison to the frameless stereotaxy group (mean 0.57 vs. 0.90; p = 0.0018). There was no difference between deep-seated and lobar hematomas with regard to the accuracy of catheter placement (p = 0.62). The RE is a robust measure for describing intrahematomal catheter position. The preregistered stylet facilitates a satisfactory catheter placement and is a viable alternative to frameless stereotaxy and guidance with the articulated arm.
Winkle, Roger A; Mead, R Hardwin; Engel, Gregory; Patrawala, Rob A
2011-05-01
Point-by-point use of open irrigated tip catheters (OITCs) at 50 W increases atrial fibrillation (AF) ablation cure rates but also increases complications. We determined if constantly moving the OITC (perpetual motion) when using 50 W increases ablation cure rates without increasing complications. We evaluated procedural data, complications, and individual procedure cure rates (IPCRs) for AF ablation using closed tip catheters (CTC) versus OITC at 40, 45, and 50 W in 1,122 ablations. We used "perpetual motion" to move the OITC at 50 W every 3-10 seconds. The OITC showed higher IPCR than CTC at 45 W (P = 0.012) and 50 W (P < 0.0005). For the OITC, IPCR increased from 44.6% to 60.7% as power increased from 40 to 50 W (P = 0.008). The OITC appeared superior to the CTC for all types of AF. For paroxysmal AF, increasing OITC power from 40 to 50 W provided no increase in IPCR (70.6% vs 71.2%, P = 0.827). For persistent AF, increasing power from 40 to 50 W increased IPCR from 34.5% to 59.5% (P = 0.001). Complications were similar for the CTC and the OITC at any power. The OITC at 50 W had shorter procedure, left atrial, and fluoroscopy times (P < 0.0005). Increasing OITC power from 40 to 50 W increases IPCR with no increase in complications as long as the 50 W setting is done using "perpetual motion." The OITC 50 W power setting results in shorter procedure and fluoroscopy times and should be considered for AF ablations. ©2010, The Authors. Journal compilation ©2010 Wiley Periodicals, Inc.
Chu, James C.H.; Hsi, Wen Chien; Hubbard, Lincoln; Zhang, Yunkai; Bernard, Damian; Reeder, Pamela; Lopes, Demetrius
2005-01-01
A hospital‐based magnetic guidance system (MGS) was installed to assist a physician in navigating catheters and guide wires during interventional cardiac and neurosurgical procedures. The objective of this study is to examine the performance of this magnetic field‐guided navigation system. Our results show that the system's radiological imaging components produce images with quality similar to that produced by other modern fluoroscopic devices. The system's magnetic navigation components also deflect the wire and catheter tips toward the intended direction. The physician, however, will have to oversteer the wire or catheter when defining the steering angle during the procedure. The MGS could be clinically useful in device navigation deflection and vessel access. PACS numbers: 07.55.Db, 07.85.‐m PMID:16143799
DOE Office of Scientific and Technical Information (OSTI.GOV)
Owen, Richard J., E-mail: drrichardowen@tbwifi.c; Mercer, John R.; Al-Saif, Faisal
2009-05-15
The distribution of radiolabeled polyvinyl alcohol microspheres (PVAMs) when infused into the portal vein of domestic swine was investigated, with the purpose of assessing implications for pancreatic islet cell transplantation. PVAMs measuring 100-300 {mu}m (Contour SE) and labeled with {sup 99m}Tc were infused into the main portal vein of 12 swine, with intermittent portal venous pressure measurements. The infusion catheter was introduced antegradely via direct or indirect cannulation of the portal vein. The liver was subsequently divided into anatomical segments. Radioactivity (decay corrected) was measured for {sup 99m}Tc microsphere synthesis, dose preparation, gross organ activities, tissue samples, and blood. Particulatemore » labeling, catheter positioning, and infusion were successful in all cases. The number of particles used was (185,000 {+-} 24,000) with a volume of 1 ml. Mean portal pressure at 5 min was significantly higher than baseline, but without a significant difference at 15 min. Extrahepatic tissue and serum radioactivity was negligible. A significant difference in number of radioactive particles per gram was detected between segments 6/7 and segments 5/8. Intrasegmental activity was analyzed, and for segments 2/3 a significant difference in the percentage dose per gram across samples was demonstrated (P = 0.001). Effective and stable radiolabeling of PVAMs with {sup 99m}Tc-sulfur colloid was demonstrated. Portal venous infusion of 100- to 300-{mu}m particles showed entrapment in the sinusoidal hepatic system with transient portal pressure elevation. Preferential embolization into the right lateral and posterior segments occurs, suggesting that flow dynamics/catheter tip position plays a role in particle distribution.« less
Prospective comparison of two management strategies of central venous catheters in burn patients.
Kealey, G P; Chang, P; Heinle, J; Rosenquist, M D; Lewis, R W
1995-03-01
Central venous catheters (CVCs) are associated with sepsis in burn patients. This study was undertaken to compare two strategies of CVC management in patients with major burn injuries. Forty-two burn patients with major burn injuries were randomly assigned to undergo site change every 48 hours of the CVC or to undergo wire guide exchange of the CVC every 48 hours at the same site. Catheter insertion site, distance from the burn wound, cultures of catheter tips, and blood cultures were obtained from all patients in a prospective manner. There was no difference in the incidence of CVC sepsis between the two groups studied. CVCs inserted less than 5 cm from the burn wound developed bacterial contamination at an earlier time than CVCs inserted more than 5 cm from the burn wound. There was no advantage to changing the CVC insertion site every 48 hours. Changing the CVC using the wire guide technique did not prevent, nor predict, CVC bacterial contamination.
Rebahi, H; El Adib, A G; Mouaffak, Y; El Hattaoui, M; Chaara, A; Sadek, H; Khouchani, M; Mahmal, L; Younous, S
2015-01-01
Totally implantable venous access port plays a crucial role in the treatment of patients in oncology. However, its use can result sporadically in catheter fracture with catheter tip embolization into pulmonary arteries. We report this unusual but potentially serious complication in four patients. In these patients, the port had been inserted percutaneously into the subclavian vein using the infra-clavicular approach. This side effect occurred late in three patients. In all patients, the catheter fracture was asymptomatic or pauci-symptomatic and was caused by the pinch-off syndrome. The retrieval of the embolized fragments was successfully performed by transcatheter procedure in the cardiac catheterisation laboratory. We reviewed the literature and the newest guidelines and recommendations to detail the clinico-radiological features, the possible causes of this complication and discussed means to recognize, manage and prevent it. Copyright © 2013 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.
Al-Rabea, A A; Burwen, D R; Eldeen, M A; Fontaine, R E; Tenover, F; Jarvis, W R
1998-09-01
To identify risk factors for Klebsiella pneumoniae bloodstream infections (BSI) in neonates in a hospital in the Kingdom of Saudi Arabia (KSA). Two case-control studies among hospitalized neonates during February 15-May 14, 1991, and a procedural and microbiological investigation. Hospital A, a maternity and children's hospital in KSA. Case patients had a blood culture positive for K pneumoniae after >2 days of hospitalization and had no evidence of a nonblood primary site of infection. When the 20 case patients were compared with controls, hospitalization in a critical-care unit (odds ratio [OR], 5.5; 95% confidence interval [CI95], 1.20-51.1; P=.03) was identified as a risk factor. When the case patients were compared with a second set of controls matched by critical-care status, receipt of a particular intravenous fluid (D10%/0.2NS; OR, 11.0; CI95, 1.42-85.2; P=.009) or a blood product (OR undefined; P=.04) were identified as risk factors. Infusates were administered via umbilical catheters for most case and control patients (19/20 vs 15/20, P>.05); catheters were manipulated more frequently in patients in critical-care units. Umbilical catheter tip, skin, or mucus membrane K pneumoniae colonization occurred in 47% and 53% of evaluated case and control patients, respectively. Available K pneumoniae isolates from blood cultures and colonization sites had identical antimicrobial susceptibility patterns. Emphasis on handwashing, careful preparation and administration of infusates, and aseptic technique for catheter insertion, maintenance, and manipulation was temporally associated with resolution of the epidemic. This outbreak was probably due to infusion therapy practices that led to BSI in nursery patients colonized with K pneumoniae. Both catheter-related infections and extrinsic contamination of infusates may have occurred. Hospital personnel should be aware of their potential to spread nosocomial pathogens from person to person and should implement Centers for Disease Control and Prevention recommendations to decrease nosocomial BSIs.
Losey, Aaron D; Lillaney, Prasheel; Martin, Alastair J; Cooke, Daniel L; Wilson, Mark W; Thorne, Bradford R H; Sincic, Ryan S; Arenson, Ronald L; Saeed, Maythem; Hetts, Steven W
2014-06-01
To compare in vitro navigation of a magnetically assisted remote-controlled (MARC) catheter under real-time magnetic resonance (MR) imaging with manual navigation under MR imaging and standard x-ray guidance in endovascular catheterization procedures in an abdominal aortic phantom. The 2-mm-diameter custom clinical-grade microcatheter prototype with a solenoid coil at the distal tip was deflected with a foot pedal actuator used to deliver 300 mA of positive or negative current. Investigators navigated the catheter into branch vessels in a custom cryogel abdominal aortic phantom. This was repeated under MR imaging guidance without magnetic assistance and under conventional x-ray fluoroscopy. MR experiments were performed at 1.5 T by using a balanced steady-state free precession sequence. The mean procedure times and percentage success data were determined and analyzed with a linear mixed-effects regression analysis. The catheter was clearly visible under real-time MR imaging. One hundred ninety-two (80%) of 240 turns were successfully completed with magnetically assisted guidance versus 144 (60%) of 240 turns with nonassisted guidance (P < .001) and 119 (74%) of 160 turns with standard x-ray guidance (P = .028). Overall mean procedure time was shorter with magnetically assisted than with nonassisted guidance under MR imaging (37 seconds ± 6 [standard error of the mean] vs 55 seconds ± 3, P < .001), and time was comparable between magnetically assisted and standard x-ray guidance (37 seconds ± 6 vs 44 seconds ± 3, P = .045). When stratified by angle of branch vessel, magnetic assistance was faster than nonassisted MR guidance at turns of 45°, 60°, and 75°. In this study, a MARC catheter for endovascular navigation under real-time MR imaging guidance was developed and tested. For catheterization of branch vessels arising at large angles, magnetically assisted catheterization was faster than manual catheterization under MR imaging guidance and was comparable to standard x-ray guidance.
Sigmund, Elisabeth; Puererfellner, Helmut; Derndorfer, Michael; Kollias, Georgios; Winter, Siegmund; Aichinger, Josef; Nesser, Hans-Joachim; Martinek, Martin
2015-02-01
Sufficient electrode-tissue contact is crucial for adequate lesion formation in radiofrequency catheter ablation (RFCA). We assessed the impact of direct catheter force measurement on acute procedural parameters and outcome of RFCA for paroxysmal and persistent atrial fibrillation (AF). Ninety-nine consecutive patients (70% men) with paroxysmal (63.6%) or persistent AF underwent left atrial RFCA using a 3.5-mm open-irrigated-tip (OIT) catheter with contact force measurement capabilities (group 1). For comparison a case-matched cohort with standard OIT catheters was used (99 patients; group 2). Case matching included gender, type of AF, number or RFCA procedures, and type of procedure. Procedural data showed a significant decline in radiofrequency ablation time from 52 ± 20 to 44 ± 16 minutes (P = 0.003) with a remarkable mean reduction in overall procedure time of 34 minutes (P = 0.0001; 225.8 ± 53.1 vs 191.9 ± 53.3 minutes). In parallel, the total fluoroscopy time could be significantly reduced from 28.5 ± 11.0 to 19.9 ± 9.3 minutes (P = 0.0001) as well as fluoroscopy dose from 74.1 ± 58.0 to 56.7 ± 38.9 Gy/cm(2) (P = 0.016). Periprocedural complications were similar in both groups. The use of contact force sensing technology is able to significantly reduce ablation, procedure, and fluoroscopy times as well as dose in RFCA of AF in a mixed case-matched group of paroxysmal and persistent AF. Energy delivery is substantially reduced by avoiding radiofrequency ablation in positions with insufficient surface contact. Additionally 12-month outcome data showed increased efficacy. Such time saving and equally safe technology may have a relevant impact on laboratory management and increased cost effectiveness. © 2014 Wiley Periodicals, Inc.
The Role Of Contact Force In Atrial Fibrillation Ablation.
Nakagawa, Hiroshi; Jackman, Warren M
2014-01-01
During radiofrequency (RF) ablation, low electrode-tissue contact force (CF) is associated with ineffective RF lesion formation, whereas excessive CF may increase the risk of steam pop and perforation. Recently, ablation catheters using two technologies have been developed to measure real-time catheter-tissue CF. One catheter uses three optical fibers to measure microdeformation of a deformable body in the catheter tip. The other catheter uses a small spring connecting the ablation tip electrode to the catheter shaft with a magnetic transmitter and sensors to measure microdeflection of the spring. Pre-clinical experimental studies have shown that 1) at constant RF power and application time, RF lesion size significantly increases with increasing CF; 2) the incidence of steam pop and thrombus also increase with increasing CF; 3) modulating RF power based on CF (i.e, high RF power at low CF and lower RF power at high CF) results in a similar and predictable RF lesion size. In clinical studies in patients undergoing pulmonary vein (PV) isolation, CF during mapping in the left atrium and PVs showed a wide range of CF and transient high CF. The most common high CF site was located at the anterior/rightward left atrial roof, directly beneath the ascending aorta. There was a poor relationship between CF and previously used surrogate parameters for CF (unipolar or bipolar atrial potential amplitude and impedance). Patients who underwent PV isolation with an average CF of <10 g experienced higher AF recurrence, whereas patients with ablation using an average CF of > 20g had lower AF recurrence. AF recurred within 12 months in 6 of 8 patients (75%) who had a mean Force-Time Integral (FTI, area under the curve for contact force vs. time) < 500 gs. In contrast, AF recurred in only 4 of 13 patients (21%) with ablation using a mean FTI >1000 gs. In another study, controlling RF power based on CF prevented steam pop and impedance rise without loss of lesion effectiveness. These studies confirm that CF is a major determinant of RF lesion size and future systems combining CF, RF power and application time may provide real-time assessment of lesion formation.
Central venous catheters: legal issues.
Gallieni, Maurizio; Martina, Valentina; Rizzo, Maria Antonietta; Gravellone, Luciana; Mobilia, Francesca; Giordano, Antonino; Cusi, Daniele; Genovese, Umberto
2011-01-01
In dialysis patients, both central venous catheter (CVC) insertion and CVC use during the dialysis procedure pose important legal issues, because of potentially severe, even fatal, complications. The first issue is the decision of the kind of vascular access that should be proposed to patients: an arteriovenous (AV) fistula, a graft, or a CVC. The second issue, when choosing the CVC option, is the choice of CVC: nontunneled versus tunneled. Leaving a temporary nontunneled CVC for a prolonged time increases the risk of complications and could raise a liability issue. Even when choosing a long-term tunneled CVC, nephrologists should systematically explain its potential harms, presenting them as "unsafe for long-term use" unless there is a clear contraindication to an AV native or prosthetic access. Another critical issue is the preparation of a complete, informative, and easy-to-understand consent form. The CVC insertion procedure has many aspects of legal interest, including the choice of CVC, the use of ECG monitoring, the use of ultrasound guidance for cannulation, and the use of fluoroscopy for checking the position of the metal guidewire during the procedure as well as the CVC tip before the end of the procedure. Use of insertion devices and techniques that can prevent complications should obviously be encouraged. Complications of CVC use are mainly thrombosis and infection. These are theoretically expected as pure complications (and not as malpractice effects), but legal issues might relate to inappropriate catheter care (in both the inpatient and outpatient settings) rather than to the event per se. Thus, in the individual case it is indeed very difficult to establish malpractice and liability with a catheter-related infection or thrombosis. In conclusion, we cannot avoid complications completely when using CVCs, but reducing them to a minimum and adopting safe approaches to their insertion and use will reduce legal liability.
Zhang, Linshuai; Guo, Shuxiang; Yu, Huadong; Song, Yu; Tamiya, Takashi; Hirata, Hideyuki; Ishihara, Hidenori
2018-02-23
The robot-assisted catheter system can increase operating distance thus preventing the exposure radiation of the surgeon to X-ray for endovascular catheterization. However, few designs have considered the collision protection between the catheter tip and the vessel wall. This paper presents a novel catheter operating system based on tissue protection to prevent vessel puncture caused by collision. The integrated haptic interface not only allows the operator to feel the real force feedback, but also combines with the newly proposed collision protection mechanism (CPM) to mitigate the collision trauma. The CPM can release the catheter quickly when the measured force exceeds a certain threshold, so as to avoid the vessel puncture. A significant advantage is that the proposed mechanism can adjust the protection threshold in real time by the current according to the actual characteristics of the blood vessel. To verify the effectiveness of the tissue protection by the system, the evaluation experiments in vitro were carried out. The results show that the further collision damage can be effectively prevented by the CPM, which implies the realization of relative safe catheterization. This research provides some insights into the functional improvements of safe and reliable robot-assisted catheter systems.
Ablordeppey, Enyo A; Drewry, Anne M; Beyer, Alexander B; Theodoro, Daniel L; Fowler, Susan A; Fuller, Brian M; Carpenter, Christopher R
2017-04-01
We performed a systematic review and meta-analysis to examine the accuracy of bedside ultrasound for confirmation of central venous catheter position and exclusion of pneumothorax compared with chest radiography. PubMed, Embase, Cochrane Central Register of Controlled Trials, reference lists, conference proceedings and ClinicalTrials.gov. Articles and abstracts describing the diagnostic accuracy of bedside ultrasound compared with chest radiography for confirmation of central venous catheters in sufficient detail to reconstruct 2 × 2 contingency tables were reviewed. Primary outcomes included the accuracy of confirming catheter positioning and detecting a pneumothorax. Secondary outcomes included feasibility, interrater reliability, and efficiency to complete bedside ultrasound confirmation of central venous catheter position. Investigators abstracted study details including research design and sonographic imaging technique to detect catheter malposition and procedure-related pneumothorax. Diagnostic accuracy measures included pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. Fifteen studies with 1,553 central venous catheter placements were identified with a pooled sensitivity and specificity of catheter malposition by ultrasound of 0.82 (0.77-0.86) and 0.98 (0.97-0.99), respectively. The pooled positive and negative likelihood ratios of catheter malposition by ultrasound were 31.12 (14.72-65.78) and 0.25 (0.13-0.47). The sensitivity and specificity of ultrasound for pneumothorax detection was nearly 100% in the participating studies. Bedside ultrasound reduced mean central venous catheter confirmation time by 58.3 minutes. Risk of bias and clinical heterogeneity in the studies were high. Bedside ultrasound is faster than radiography at identifying pneumothorax after central venous catheter insertion. When a central venous catheter malposition exists, bedside ultrasound will identify four out of every five earlier than chest radiography.
Kim, Pascal; Meyer, Urs; Schüpfer, Guido; Rukwied, Roman; Konrad, Christoph; Gerber, Helmut
2011-01-01
Epidural analgesia is an established method for pain management. The failure rate is 8% to 12% due to technical difficulties (catheter dislocation and/or disconnection; partial or total catheter occlusion) and management. The mechanical properties of the catheters, like tensile strength and flow rate, may also be affected by the analgesic solution and/or the tissue environment. We investigated the tensile strength and perfusion pressure of new (n=20), perioperatively (n=30), and postoperatively (n=73) used epidural catheters (20-gauge, polyamide, closed tip, 3 side holes; Perifix [B. Braun]). To prevent dislocation, epidural catheters were taped (n=5) or fixed by suture (n=68) to the skin. After removal, mechanical properties were assessed by a tensile-testing machine (INSTRON 4500), and perfusion pressure was measured at flow rates of 10, 20, and 40 mL/h. All catheters demonstrated a 2-step force transmission. Initially, a minimal increase of length could be observed at 15 N followed by an elongation of several cm at additional forces (7 N). Breakage occurred in the control group at 23.5±1.5 N compared with 22.4±1.6 N in perioperative and 22.4±1.7 N in postoperative catheters (P<0.05). Duration of catheter use had no effect on tensile strength, whereas perfusion pressure at clinically used flow rates (10 mL/h) increased significantly from 19±1.3 to 44±72 mm Hg during long-term (≥7 days) epidural analgesia (P<0.05, analysis of variance). Fixation by suture had no influence on tensile strength or perfusion pressure. Epidural catheter use significantly increases the perfusion pressure and decreases the tensile strength. Copyright © 2011 by American Society of Regional Anesthesia and Pain Medicine
Complications of intra-cardial placement of silastic central venous catheter in pediatric patients.
Soong, W J; Jeng, M J; Hwang, B
1996-01-01
A three-year prospective study was undertaken to determine the incidence and early complications from intra-cardiac placement of percutaneous central venous catheter (CVC). CVC was inserted by using "Catheter-through-needle" technique, and the insertion length was measured by body surface landmark. CVC course and tip location were routinely checked by roentgenography. Echocardiography was performed in case of arrhythmia. After analysis of 784 CVCs, 104 (13.3%) were proved to be intra-cardial, as located by either roentgenography or echocardiography. However, catheters passed via the upper trunk (14.5%) were significantly (p < 0.05) more intra-cardially located than those via the lower trunk (4.8%). Catheters which passed via the right upper trunk veins (basilic, cephalic, or external jugular veins) were also more intra-cardially located than those via their left veins counterparts, but the finding was not statistically significant (p > 0.05). The mean body weight (3.1 +/- 2.4 kg) in the intra-cardial placement group was significantly (p < 0.05) less than that in the non-intracardial placement group (7.9 +/- 4.5 kg). In intra-cardial placement patients, 32 cases (30.8%) had episode(s) of cardiac arrhythmia including 31 premature ventricular depolarization and 1 supra-ventricular tachycardia. All cases showed the presence of intra-ventricular catheter. All arrhythmias ceased abruptly after the catheters were pulled from the hearts. No other early complications were observed. the incidence of the intracardiac placement of CVC is high, especially in small infants or when the insertion via the upper trunk. Short term intra-cardiac catheter placement has a benign clinical course except that the intraventricular catheter may cause arrhythmia. However, this kind of arrhythmia can be resolved spontaneously by withdrawing the catheter.
Retrograde pyelogram using the flexible cystoscope.
Reddy, P K; Hulbert, J C
1986-12-01
A retrograde pyelogram was performed on 2 men with the flexible choledochonephroscope and a 5F whistle-tip ureteral catheter. The procedure was done on an outpatient basis with topical anesthesia and patient tolerance was good. The technique is simple and is a useful alternative to the classical rigid cystoscopic technique.
Gurjarpadhye, Abhijit Achyut; DeWitt, Matthew R.; Xu, Yong; Wang, Ge; Rylander, Marissa Nichole
2015-01-01
Background: Lumen endothelialization of bioengineered vascular scaffolds is essential to maintain small-diameter graft patency and prevent thrombosis postimplantation. Unfortunately, nondestructive imaging methods to visualize this dynamic process are lacking, thus slowing development and clinical translation of these potential tissue-engineering approaches. To meet this need, a fluorescence imaging system utilizing a commercial optical coherence tomography (OCT) catheter was designed to visualize graft endothelialization. Methods: C7 DragonFly™ intravascular OCT catheter was used as a channel for delivery and collection of excitation and emission spectra. Poly-dl-lactide (PDLLA) electrospun scaffolds were seeded with endothelial cells (ECs). Seeded cells were exposed to Calcein AM before imaging, causing the living cells to emit green fluorescence in response to blue laser. By positioning the catheter tip precisely over a specimen using high-fidelity electromechanical components, small regions of the specimen were excited selectively. The resulting fluorescence intensities were mapped on a two-dimensional digital grid to generate spatial distribution of fluorophores at single-cell-level resolution. Fluorescence imaging of endothelialization on glass and PDLLA scaffolds was performed using the OCT catheter-based imaging system as well as with a commercial fluorescence microscope. Cell coverage area was calculated for both image sets for quantitative comparison of imaging techniques. Tubular PDLLA scaffolds were maintained in a bioreactor on seeding with ECs, and endothelialization was monitored over 5 days using the OCT catheter-based imaging system. Results: No significant difference was observed in images obtained using our imaging system to those acquired with the fluorescence microscope. Cell area coverage calculated using the images yielded similar values. Nondestructive imaging of endothelialization on tubular scaffolds showed cell proliferation with cell coverage area increasing from 15±4% to 89±6% over 5 days. Conclusion: In this study, we showed the capability of an OCT catheter-based imaging system to obtain single-cell resolution and to quantify endothelialization in tubular electrospun scaffolds. We also compared the resulting images with traditional microscopy, showing high fidelity in image capability. This imaging system, used in conjunction with OCT, could potentially be a powerful tool for in vitro optimization of scaffold cellularization, ensuring long-term graft patency postimplantation. PMID:25539889
Real time magnetic resonance guided endomyocardial local delivery
Corti, R; Badimon, J; Mizsei, G; Macaluso, F; Lee, M; Licato, P; Viles-Gonzalez, J F; Fuster, V; Sherman, W
2005-01-01
Objective: To investigate the feasibility of targeting various areas of left ventricle myocardium under real time magnetic resonance (MR) imaging with a customised injection catheter equipped with a miniaturised coil. Design: A needle injection catheter with a mounted resonant solenoid circuit (coil) at its tip was designed and constructed. A 1.5 T MR scanner with customised real time sequence combined with in-room scan running capabilities was used. With this system, various myocardial areas within the left ventricle were targeted and injected with a gadolinium-diethylenetriaminepentaacetic acid (DTPA) and Indian ink mixture. Results: Real time sequencing at 10 frames/s allowed clear visualisation of the moving catheter and its transit through the aorta into the ventricle, as well as targeting of all ventricle wall segments without further image enhancement techniques. All injections were visualised by real time MR imaging and verified by gross pathology. Conclusion: The tracking device allowed real time in vivo visualisation of catheters in the aorta and left ventricle as well as precise targeting of myocardial areas. The use of this real time catheter tracking may enable precise and adequate delivery of agents for tissue regeneration. PMID:15710717
Masuko, T; Higashimoto, Y; Iwai, J
2005-11-01
Colorectal decompression with a catheter was performed for evacuation of stool before definitive surgery in two patients with a persistent cloaca. Two newborn female infants with persistent cloaca received placement of a silicone balloon-tipped catheter in the rectum via the cloacal orifice under fluoroscopic guidance at the time of diagnosis. The length of the cloaca was 2 and 1.5 cm, respectively. The diameter of the catheter was matched to the patients' rectal size and the open end was wrapped in a diaper to allow continuous drainage of stool. The infants underwent bowel irrigation with warm saline thrice a day, at home. Total urogenital mobilization was carried out in the infants at the age of 7 and 8 months, respectively. Both infants had no abdominal distension, colorectal dilatation, or urinary tract infection while the catheter was in situ. The postoperative course was uneventful, except for minimal wound dehiscence in one patient. At present, both infants can void spontaneously without any urological problems. In infants with a persistent cloaca less than 3 cm long and normal urinary tract function, adequate evacuation of stool may be achieved by colorectal decompression with a catheter, thus avoiding the need for a colostomy.
Telemetric implantable pressure sensor for short- and long-term monitoring of intracranial pressure.
Frischholz, M; Sarmento, L; Wenzel, M; Aquilina, K; Edwards, R; Coakham, H B
2007-01-01
Patients with hydrocephalus, idiopathic intracranial hypertension and head injury frequently require monitoring of intracranial pressure (ICP) and may need repeated episodes of monitoring months or years apart. The gold standard for measurement of ICP remains the external ventricular catheter. This is a fluid-filled catheter transducer system that allows regular recalibration and correction of zero drift by its position relative to a fixed anatomical reference. It also allows drainage of cerebrospinal fluid (CSF), providing a means of lowering the ICP. Several catheter tip transducer systems are currently in clinical use, including using strain gauges or fiber-optical pressure sensing techniques. In these devices, zero drift and calibration cannot be checked in vivo. All the ICP monitoring devices in current clinical use require a physical connection between the brain and the external environment. This is a source of infection and limits the duration of monitoring. A number of telemetric monitoring devices, in which data is in some way transmitted transcutaneously, have been developed over the last twenty years, but significant technical problems have precluded their use in routine clinical practice. All current ICP monitors are temporary percutaneous implanted devices. Placement of these devices carries significant morbidity, particularly infection. Patients undergoing repeated monitoring require multiple surgical procedures. Apart from decreasing the risk of infection in patients with severe head injury, the clinical value of an accurate telemetric ICP monitoring system which maintains its reliability over a long period of implantation is high.
Moonens, F; el Alami, S; Van Gossum, A; Struelens, M J; Serruys, E
1994-01-01
The accuracy of Gram staining of blood drawn from catheters used to administer total parenteral nutrition was compared with paired quantitative blood cultures for the diagnosis of catheter-related sepsis. Gram staining was positive in 11 of 18 episodes of catheter-related sepsis documented by quantitative culture (sensitivity, 61%) but in none of the 5 episodes of fever unrelated to catheter infection. Thus, this procedure enabled the rapid presumptive diagnosis and guidance of antimicrobial therapy for total parenteral nutrition catheter sepsis, with a positive predictive value of 100% and a negative predictive value of 42%. PMID:7521359
Lim, S H; Smith, M P; Machin, S J; Goldstone, A H
1993-01-01
In all, 88 patients with haematological malignancies requiring Hickman catheters for intensive chemotherapy were randomized to receive either one single bolus intravenous injection of teicoplanin, 400 mg, or no teicoplanin immediately before insertion of a double-lumen Hickman catheter. Lower incidences of catheter-related Gram-positive sepsis were recorded in patients receiving prophylactic teicoplanin; exit site infection, tunnel infection and catheter-related Gram-positive septicaemia were all reduced. The benefit of prophylactic teicoplanin was observed particularly among patients who were already neutropenic at the time of catheterization. All Gram-positive organisms isolated from infected skin sites or from blood cultures taken from Hickman catheters were susceptible to teicoplanin. No adverse reaction was reported in any of the patients receiving prophylaxis. Prophylactic teicoplanin, therefore, may be used routinely for patients requiring insertion of Hickman catheters for intensive chemotherapy, to reduce the early incidence of catheter-related sepsis, particularly during the period of neutropenia following chemotherapy.
Lim, S H; Smith, M P; Salooja, N; Machin, S J; Goldstone, A H
1991-07-01
Eighty-eight patients with haematological malignancies requiring Hickman catheters for intensive chemotherapy were randomized to receive either one single bolus intravenous injection of teicoplanin or no teicoplanin immediately before insertion of a double lumen Hickman catheter. There were lower incidences of catheter-related Gram-positive sepsis in patients receiving prophylactic teicoplanin. There were less exit site infections, tunnel infections and catheter-related Gram-positive septicaemia. The benefit of prophylactic teicoplanin was observed especially among patients who were already neutropenic at the time of catheterization. All Gram-positive organisms isolated from the infected skin sites or from blood cultures taken from the Hickman catheters were sensitive to teicoplanin. No adverse reaction was reported in any of the patients in the prophylactic group. Prophylactic teicoplanin therefore may be used routinely for patients requiring insertion of Hickman catheters for intensive chemotherapy to reduce the early incidence of catheter-related sepsis, especially during the associated period of neutropenia following chemotherapy.
[Central venous catheter-related infections in critically ill patients].
Diener, J R; Coutinho, M S; Zoccoli, C M
1996-01-01
To determine incidence rate, etiology and risk factors for central venous catheter (CVC)-related infections in critically-ill patients, a prospective cohort study was conducted in the general Intensive Care Unit (ICU) of a 212 bed Hospital in Florianópolis, Brazil. Patients admitted to ICU between May 1993 and February 1994, exposed to short-term CVC, were included in the study. Quantitative skin culture at CVC insertion site, semi-quantitative CVC tip culture, quantitative hub culture, and peripheral blood-culture were done. Results were submitted to univariate and multivariate analysis. Fifty-seven catheterization periods were analysed in 51 patients. The incidence rate was 21.1% (33.1 per 1,000 catheter-days) for local infection, and 8.7% (14.1 per 1,000 catheter-days) for catheter-associated bacteremia. The skin at the insertion site was colonized in 32.7% and the hub in 29.1% of the patients respectively. Potential sources of infection were the skin in 41.2% of the cases, the hub in 29.4%, remote site in 5.9% and unknown in 23.5%. The hub was implicated in 60% of the catheter-associated bacteremias. Coagulase-negative staphylococci were the main isolates. Another intravascular device and purulence at the insertion site were independently associated with local infection. Insertion at internal jugular site and hub colonization were independently associated with bacteremia. Catheter-associated bacteremia is a major complication of central venous catheterization in critically-ill patients. Internal jugular insertion and CVC hub colonization are important risk factors for significant catheter-related infections.
Sankey, Eric W; Butler, Eric; Sampson, John H
2017-10-01
To evaluate accuracy of a computed tomography (CT)-guided frameless stereotactic drilling and catheter system. A prospective, single-arm study was performed using human cadaver heads to evaluate placement accuracy of a novel, flexible intracranial catheter and stabilizing bone anchor system and drill kit. There were 20 catheter placements included in the analysis. The primary endpoint was accuracy of catheter tip location on intraoperative CT. Secondary endpoints included target registration error and entry and target point error before and after drilling. Measurements are reported as mean ± SD (median, range). Target registration error was 0.46 mm ± 0.26 (0.50 mm, -1.00 to 1.00 mm). Two (10%) target point trajectories were negatively impacted by drilling. Intracranial catheter depth was 59.8 mm ± 9.4 (60.5 mm, 38.0-80.0 mm). Drilling angle was 22° ± 9 (21°, 7°-45°). Deviation between planned and actual entry point on CT was 1.04 mm ± 0.38 (1.00 mm, 0.40-2.00 mm). Deviation between planned and actual target point on CT was 1.60 mm ± 0.98 (1.40 mm, 0.40-4.00 mm). No correlation was observed between intracranial catheter depth and target point deviation (accuracy) (Pearson coefficient 0.018) or between technician experience and accuracy (Pearson coefficient 0.020). There was no significant difference in accuracy with trajectories performed for different cadaver heads (P = 0.362). Highly accurate catheter placement is achievable using this novel flexible catheter and bone anchor system placed via frameless stereotaxy, with an average deviation between planned and actual target point of 1.60 mm ± 0.98 (1.40 mm, 0.40-4.00 mm). Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goltz, Jan P., E-mail: Goltz@roentgen.uni-wuerzburg.de; Scholl, Anne; Ritter, Christian O.
The aim of this study is to evaluate the effectiveness and safety of percutaneously placed totally implantable venous-access ports (TIVAPs) of the forearm. Between January 2006 and October 2008, peripheral TIVAPs were implanted in 763 consecutive patients by ultrasound and fluoroscopic guidance. All catheters were implanted under local anesthesia and were tunneled subcutaneously. Indication, technical success, and complications were retrospectively analyzed according to Society of Interventional Radiology (SIR) criteria. Presence of antibiotic prophylaxis, periprocedurally administered drugs (e.g., sedation), and laboratory results at the time of implantation were analyzed. Maintenance during the service interval was evaluated. In total, 327,499 catheter-days weremore » analyzed. Technical success rate was 99.3%. Reasons for initial failure of implantation were either unexpected thrombosis of the subclavian vein, expanding tumor mass of the mediastinum, or failure of peripheral venous access due to fragile vessels. Mean follow-up was 430 days. There were 115 complications observed (15.1%, 0.03 per 100 catheter-days), of which 33 (4.3%) were classified as early (within 30 days from implantation) and 82 (10.7%) as late. Catheter-related venous thrombosis was found in 65 (8.5%) of 763 (0.02 per 100 catheter-days) TIVAPs. Infections were observed in 41 (5.4%) of 763 (0.01 per 100 catheter-days) devices. Other complications observed included dislocation of the catheter tip (0.8%), occlusion (0.1%), or rupture (0.1%) of the port catheter. Dislocated catheters were corrected during a second interventional procedure. In conclusion, implantation of percutaneously placed peripheral TIVAPs shows a high technical success rate and low risk of early complications when ultrasound and fluoroscopic guidance are used. Late complications are observed three times as often as early complications.« less
Ablordeppey, Enyo A.; Drewry, Anne M.; Beyer, Alexander B.; Theodoro, Daniel L.; Fowler, Susan A.; Fuller, Brian M.; Carpenter, Christopher R.
2016-01-01
Objective We performed a systematic review and meta-analysis to examine the accuracy of bedside ultrasound for confirmation of central venous catheter position and exclusion of pneumothorax compared to chest radiography. Data Sources PubMed, EMBASE, Cochrane Central Register of Controlled Trials, reference lists, conference proceedings and ClinicalTrials.gov Study Selection Articles and abstracts describing the diagnostic accuracy of bedside ultrasound compared with chest radiography for confirmation of central venous catheters in sufficient detail to reconstruct 2×2 contingency tables were reviewed. Primary outcomes included the accuracy of confirming catheter positioning and detecting a pneumothorax. Secondary outcomes included feasibility, inter-rater reliability, and efficiency to complete bedside ultrasound confirmation of central venous catheter position. Data Extraction Investigators abstracted study details including research design and sonographic imaging technique to detect catheter malposition and procedure-related pneumothorax. Diagnostic accuracy measures included pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. Data Synthesis 15 studies with 1553 central venous catheter placements were identified with a pooled sensitivity and specificity of catheter malposition by ultrasound of 0.82 [0.77, 0.86] and 0.98 [0.97, 0.99] respectively. The pooled positive and negative likelihood ratios of catheter malposition by ultrasound were 31.12 [14.72, 65.78] and 0.25 [0.13, 0.47]. The sensitivity and specificity of ultrasound for pneumothorax detection was nearly 100% in the participating studies. Bedside ultrasound reduced mean central venous catheter confirmation time by 58.3 minutes. Risk of bias and clinical heterogeneity in the studies were high. Conclusions Bedside ultrasound is faster than radiography at identifying pneumothorax after central venous catheter insertion. When a central venous catheter malposition exists, bedside ultrasound will identify four out of every five earlier than chest radiography. PMID:27922877
21 CFR 868.1150 - Indwelling blood carbon dioxide partial pressure (PCO2) analyzer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Indwelling blood carbon dioxide partial pressure....1150 Indwelling blood carbon dioxide partial pressure (PCO2) analyzer. (a) Identification. An indwelling blood carbon dioxide partial pressure PCO2 analyzer is a device that consists of a catheter-tip...
21 CFR 868.1150 - Indwelling blood carbon dioxide partial pressure (PCO2) analyzer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Indwelling blood carbon dioxide partial pressure....1150 Indwelling blood carbon dioxide partial pressure (PCO2) analyzer. (a) Identification. An indwelling blood carbon dioxide partial pressure PCO2 analyzer is a device that consists of a catheter-tip...
21 CFR 868.1150 - Indwelling blood carbon dioxide partial pressure (PCO2) analyzer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Indwelling blood carbon dioxide partial pressure....1150 Indwelling blood carbon dioxide partial pressure (PCO2) analyzer. (a) Identification. An indwelling blood carbon dioxide partial pressure PCO2 analyzer is a device that consists of a catheter-tip...
21 CFR 868.1150 - Indwelling blood carbon dioxide partial pressure (PCO2) analyzer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Indwelling blood carbon dioxide partial pressure....1150 Indwelling blood carbon dioxide partial pressure (PCO2) analyzer. (a) Identification. An indwelling blood carbon dioxide partial pressure PCO2 analyzer is a device that consists of a catheter-tip...
Current concepts in the pathophysiology, evaluation, and diagnosis of compartment syndrome
NASA Technical Reports Server (NTRS)
Hargens, A. R.; Mubarak, S. J.
1998-01-01
This article reviews present knowledge of the pathophysiology and diagnosis of acute compartment syndromes. Recent results using compression of legs in normal volunteers provide objective data concerning local pressure thresholds for neuromuscular dysfunction in the anterior compartment. Results with this model indicate that a progression of neuromuscular deficits occurs when IMP increases to within 35 to 40 mm Hg of diastolic blood pressure. These findings provide useful information on the diagnosis and compression thresholds for acute compartment syndromes. Time factors are also important, however, and usually are incompletely known in most cases of acute compartment syndrome. Although the slit catheter is a very good technique for monitoring IMP during rest, these catheters and their associated extracorporeal transducer systems are not ideal. Recently developed miniature transducer-tipped catheters and, perhaps, future development of noninvasive techniques may provide accurate recordings of IMP in patients with acute compartment syndromes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Eu Hyun, E-mail: doorihyun6@gmail.com; Oh, Jung Suk; Chun, Ho Jong
PurposeThe study aimed to introduce a monorail technique to overcome difficult anatomical course via left internal jugular vein in implantable port insertion.MethodsFrom 2007 to 2016, a total of 9346 patients were referred for implantable port insertion in our interventional unit, among which 79 cases were requested to insert on the left side. Our monorail technique was applied only when the technical challenge of the catheter tip entering the azygos vein instead of the superior vena cava occurred (n = 7). The technique consists of puncturing at the distal tip of the port catheter with a 21-gauge micropuncture needle and advancing a 0.018-in.more » hair-wire to guide and provide support for pre-assembled port.ResultsThe monorail technique was performed in seven patients and all but one case were technically successful, showing a technical success rate of 85.7%. There were no immediate or delayed complications.ConclusionsThe monorail technique is helpful to overcome the difficult anatomical course via left internal jugular vein in implantable port insertion.« less
Kim, Eu Hyun; Oh, Jung Suk; Chun, Ho Jong; Lee, Hae Giu; Choi, Byung Gil
2017-03-01
The study aimed to introduce a monorail technique to overcome difficult anatomical course via left internal jugular vein in implantable port insertion. From 2007 to 2016, a total of 9346 patients were referred for implantable port insertion in our interventional unit, among which 79 cases were requested to insert on the left side. Our monorail technique was applied only when the technical challenge of the catheter tip entering the azygos vein instead of the superior vena cava occurred (n = 7). The technique consists of puncturing at the distal tip of the port catheter with a 21-gauge micropuncture needle and advancing a 0.018-in. hair-wire to guide and provide support for pre-assembled port. The monorail technique was performed in seven patients and all but one case were technically successful, showing a technical success rate of 85.7%. There were no immediate or delayed complications. The monorail technique is helpful to overcome the difficult anatomical course via left internal jugular vein in implantable port insertion.
Kato, Haruaki; Kobayashi, Shinya; Kawakami, Masako; Inoue, Hiroo; Iijima, Kazuyoshi; Nishizawa, Osamu
2004-10-01
Repair of a posterior urethral disruption associated with a pelvic fracture is a challenge for urologic surgeons. Here, we provide surgical and strategic tips to facilitate the delayed surgical repair of urethral distraction defects. Nine patients each with a traumatic posterior urethral distraction defect underwent delayed transperineal or transperineoabdominal bulboprostatic anastomosis. Four patients had previously undergone multiple procedures. Seven patients regained satisfactory urination without incontinence, although one other patient is suffering from incontinence. In one patient, urethral disruption occurred again after removal of the urethral catheter, and he is being managed by suprapubic catheter. In our experience, the key to success is to perform a true bulboprostatic mucosa-to-mucosa anastomosis without tension. For this purpose, a transperineoabdominal approach is of particular importance when the healthy mucosa of the prostatic apex cannot be revealed through a perineal approach due to dense fibrous scar or fractured bone. A partial pubectomy may be necessary according to the situation. By the transperineoabdominal approach, the scar tissue can be bypassed through a broad sub-pubic-arch tunnel, and a reliable anastomosis achieved.
Chen, Shih-Hsiang; Yang, Chao-Ping; Jaing, Tang-Her; Lai, Jin-Yao; Hung, Iou-Jih
2012-04-01
Long-term central venous catheter (CVC) implantation has become more affordable in Taiwan since 1995. Surgical removal of the catheter may be the essential treatment for catheter-related bloodstream infections (CRBSI). The aim of this study was to evaluate the clinical features and microbial isolates in pediatric cancer patients with removal of CVC for CRBSI. The records of positive blood culture from hospitalized pediatric oncology patients between 1995 and 2004 were reviewed. One hundred and forty-three patients implanted with a long-term CVC were further identified. Seventeen catheters in 16 patients developed catheter-related bacteremia that needed catheter removal. The rate of catheter removal was 11.9%. The median device life was 7.7 months. Six catheters were removed within 3 months of insertion. Nine of the 17 catheters were removed from patient younger than 2 years. Eight infections occurred during severe neutropenia, and 6 patients had refractory or relapsed underlying disease. The cultural isolates were Gram-negative bacilli in 7, Gram-positive in 5, fungi in 5, and atypical mycobacterium in 1. The frequency of catheter removal for infection control was significantly higher in the first 5 years (1994-1999) compared to the last 5 years (2000-2004) (30.9 vs. 4.0%, p = 2.3 × 10(-4)). Factors such as microbiological isolates, age of infection, the status of malignancy, and neutropenia are related to catheter outcome. The reduction in patients with positive cultures needing removal of the catheters can be related to improved nursing care and more aggressive antibiotic therapy.
Feasibility study of an active soft catheter actuated by SMA wires
NASA Astrophysics Data System (ADS)
Konh, Bardia; Karimi, Saeed; Miller, Scott
2018-03-01
This study aims to assess the feasibility of using a combination of thin elastomer tubes and SMA wires to develop an active catheter. Cardiac catheters have been widely used in investigational and interventional procedures such as angiography, angioplasty, electro- physiology, and endocardial ablation. The commercial models manually steer inside the patient's body via internally installed pull wires. Active catheters, on the other hand, have the potential to revolutionize surgical procedures because of their computer-controlled and enhanced motion. Shape memory alloys have been used for almost a decade as a trustworthy actuator for biomedical applications. In this work, SMA wires were attached to a small pressurized elastomer tube to realize deflection. The tube was pressurized to maintain a constant stress on the SMA wires. The tip motion via actuation of SMA wires was then measured and reported. The results of this study showed that by adopting an appropriate training process for the SMA wires prior to performing the experiments and adopting an appropriate internal pressure for the elastomer tube, less external loads on SMA wires would be needed for a consistent actuation.
Wang, Yao; Stephens, Douglas N; O'Donnell, Matthew
2002-12-01
Intravascular ultrasound (IVUS) imaging systems using circumferential arrays mounted on cardiac catheter tips fire beams orthogonal to the principal axis of the catheter. The system produces high resolution cross-sectional images but must be guided by conventional angioscopy. A real-time forward-viewing array, integrated into the same catheter, could greatly reduce radiation exposure by decreasing angiographic guidance. Unfortunately, the mounting requirement of a catheter guide wire prohibits a full-disk imaging aperture. Given only an annulus of array elements, prior theoretical investigations have only considered a circular ring of point transceivers and focusing strategies using all elements in the highly dense array, both impractical assumptions. In this paper, we consider a practical array geometry and signal processing architecture for a forward-viewing IVUS system. Our specific design uses a total of 210 transceiver firings with synthetic reconstruction for a given 3-D image frame. Simulation results demonstrate this design can achieve side-lobes under -40 dB for on-axis situations and under -30 dB for steering to the edge of a 80 degrees cone.
NASA Astrophysics Data System (ADS)
Irisawa, Kaku; Murakoshi, Dai; Hashimoto, Atsushi; Yamamoto, Katsuya; Hayakawa, Toshiro
2017-03-01
Visualization of the tip of medical devices like needles or catheters under ultrasound imaging has been a continuous topic since the early 1980's. In this study, a needle tip visualization system utilizing photoacoustic effects is proposed. In order to visualize the needle tip, an optical fiber was inserted into a needle. The optical fiber tip is placed on the needle bevel and affixed with black glue. The pulsed laser light from laser diode was transferred to the optical fiber and converted to ultrasound due to laser light absorption of the black glue and the subsequent photoacoustic effect. The ultrasound is detected by transducer array and reconstructed into photoacoustic images in the ultrasound unit. The photoacoustic image is displayed with a superposed ultrasound B-mode image. As a system evaluation, the needle is punctured into bovine meat and the needle tip is observed with commercialized conventional linear transducers or convex transducers. The needle tip is visualized clearly at 7 and 12 cm depths with linear and convex probes, respectively, even with a steep needle puncture angle of around 90 degrees. Laser and acoustic outputs, and thermal rise at the needle tip, were measured and were well below the limits of the safety standards. Compared with existing needle tip visualization technologies, the photoacoustic needle tip visualization system has potential distinguishable features for clinical procedures related with needle puncture and injection.
MEMS-Based Flexible Force Sensor for Tri-Axial Catheter Contact Force Measurement
Sheng, Jun; Desai, Jaydev P.
2016-01-01
Atrial fibrillation (AFib) is a significant healthcare problem caused by the uneven and rapid discharge of electrical signals from pulmonary veins (PVs). The technique of radiofrequency (RF) ablation can block these abnormal electrical signals by ablating myocardial sleeves inside PVs. Catheter contact force measurement during RF ablation can reduce the rate of AFib recurrence, since it helps to determine effective contact of the catheter with the tissue, thereby resulting in effective power delivery for ablation. This paper presents the development of a three-dimensional (3D) force sensor to provide the real-time measurement of tri-axial catheter contact force. The 3D force sensor consists of a plastic cubic bead and five flexible force sensors. Each flexible force sensor was made of a PEDOT:PSS strain gauge and a PDMS bump on a flexible PDMS substrate. Calibration results show that the fabricated sensor has a linear response in the force range required for RF ablation. To evaluate its working performance, the fabricated sensor was pressed against gelatin tissue by a micromanipulator and also integrated on a catheter tip to test it within deionized water flow. Both experiments simulated the ventricular environment and proved the validity of applying the 3D force sensor in RF ablation. PMID:28190945
Management of complications related to central venous catheters in cancer patients: an update.
Linnemann, Birgit
2014-04-01
Central venous catheters (CVCs) are important for the treatment of patients with cancer, especially in the perioperative and palliative care settings. These devices not only allow for the administration of chemotherapy, parenteral nutrition, and other intravenous therapies, but they may also improve the patients' quality of life by reducing the need for repeated peripheral venipunctures. Thrombotic and infectious complications are common, especially in the long-term use of CVCs. There are different types of thrombotic complications associated with CVCs, that is, a thrombotic occlusion of the catheter, a mural thrombus at the catheter tip and classical deep vein thrombosis, which occurs most frequently in the upper extremity where the majority of long-term catheters are inserted. Infections are common complications associated with CVCs. Patients with cancer who receive intensive chemotherapy and those patients who undergo hematopoietic stem cell transplantation have a markedly increased risk for insertion site and bloodstream infections. In this review, the epidemiology and risk factors that predispose patients to CVC-related thrombosis and infection are discussed. The diagnostic and therapeutic options according to the published data and the current guidelines are summarized and data for establishing primary and secondary preventative strategies are provided. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Vaccari Md, Diego; Giacopelli MSc, Daniele; Rocchetto MSc, Eros; Vittadello Md, Sabina; Mantovan Md, Roberto; Neri Md, Gianfilippo
2014-01-01
The tip-to-tissue contact force (CF) has been identified as a potential determinant of lesion quality during radiofrequency (RF) ablation. The aim of this paper is to report the experience of a single low-volume centre in the atrial fibrillation (AF) ablation procedure with an RF catheter capable of measuring this parameter. CF data and their possible implications on patient safety are presented. Thirty-nine consecutive patients suffering of paroxysmal or permanent AF received percutaneous ablation with the novel catheter studied. Procedural characteristics, CF applied and safety events related to the procedure were reported. During RF application the mean CF value was 17 ± 3 g, with a maximum mean value of 37 ± 8 g. CF value never exceeded 62 g and in the 74% of the RF applications ranged between 10 g and 30 g. No complication related to the catheter manipulation or to the energy delivered was observed. This study of a single centre with a low level of experience in AF ablation suggests that the ability to measure CF may provide additional useful information to the operator. It ensures uniform ablations, with little variability in the catheter manipulations, and it avoids excessive contact forces increasing the patient safety.
Prospective surveillance of phlebitis associated with peripheral intravenous catheters.
Malach, Tal; Jerassy, Ziona; Rudensky, Bernard; Schlesinger, Yechiel; Broide, Etty; Olsha, Oded; Yinnon, Amos M; Raveh, David
2006-06-01
Guidelines have been published for prevention of phlebitis associated with peripheral intravenous catheters (IVC), but this complication continues to occur. We sought to determine the rate of phlebitis associated with peripheral IVCs to identify predictors for phlebitis and to isolate pathogenic bacteria from phlebitic catheter tips. Nine-point prevalence studies were conducted during the years 1996-2003 of all hospitalized patients with a peripheral IVC. During the last 3 surveys, conducted in 2003, phlebitic lines were removed, and, for each line, 1 to 2 nonphlebitic lines, in place for 48 to 72 hours, were removed and cultured as controls. In between these surveys, findings and guidelines for improvement were distributed to the staff. During these surveys, 40% +/- 8% of hospitalized patients had a peripheral IVC. The rate of peripheral IVC-associated phlebitis decreased from 12.7% (20/157) in 1998 to 2.6% (5/189) in 2003 (P < .01). Factors significantly associated with phlebitis included pain (P < .001), presence of the catheter for longer than 3 days (P < .05), and cleanliness of the dressing (P < .01). The rate of phlebitis associated with peripheral intravenous catheters decreased significantly throughout the study period. The identification of predictors for phlebitis and the dissemination of this information in an educational drive may have contributed to this improvement.
Poor drug distribution as a possible explanation for the results of the PRECISE trial.
Sampson, John H; Archer, Gary; Pedain, Christoph; Wembacher-Schröder, Eva; Westphal, Manfred; Kunwar, Sandeep; Vogelbaum, Michael A; Coan, April; Herndon, James E; Raghavan, Raghu; Brady, Martin L; Reardon, David A; Friedman, Allan H; Friedman, Henry S; Rodríguez-Ponce, M Inmaculada; Chang, Susan M; Mittermeyer, Stephan; Croteau, David; Puri, Raj K
2010-08-01
Convection-enhanced delivery (CED) is a novel intracerebral drug delivery technique with considerable promise for delivering therapeutic agents throughout the CNS. Despite this promise, Phase III clinical trials employing CED have failed to meet clinical end points. Although this may be due to inactive agents or a failure to rigorously validate drug targets, the authors have previously demonstrated that catheter positioning plays a major role in drug distribution using this technique. The purpose of the present work was to retrospectively analyze the expected drug distribution based on catheter positioning data available from the CED arm of the PRECISE trial. Data on catheter positioning from all patients randomized to the CED arm of the PRECISE trial were available for analyses. BrainLAB iPlan Flow software was used to estimate the expected drug distribution. Only 49.8% of catheters met all positioning criteria. Still, catheter positioning score (hazard ratio 0.93, p = 0.043) and the number of optimally positioned catheters (hazard ratio 0.72, p = 0.038) had a significant effect on progression-free survival. Estimated coverage of relevant target volumes was low, however, with only 20.1% of the 2-cm penumbra surrounding the resection cavity covered on average. Although tumor location and resection cavity volume had no effect on coverage volume, estimations of drug delivery to relevant target volumes did correlate well with catheter score (p < 0.003), and optimally positioned catheters had larger coverage volumes (p < 0.002). Only overall survival (p = 0.006) was higher for investigators considered experienced after adjusting for patient age and Karnofsky Performance Scale score. The potential efficacy of drugs delivered by CED may be severely constrained by ineffective delivery in many patients. Routine use of software algorithms and alternative catheter designs and infusion parameters may improve the efficacy of drugs delivered by CED.
Gundlapalli, Adi V; Divita, Guy; Redd, Andrew; Carter, Marjorie E; Ko, Danette; Rubin, Michael; Samore, Matthew; Strymish, Judith; Krein, Sarah; Gupta, Kalpana; Sales, Anne; Trautner, Barbara W
2017-07-01
To develop a natural language processing pipeline to extract positively asserted concepts related to the presence of an indwelling urinary catheter in hospitalized patients from the free text of the electronic medical note. The goal is to assist infection preventionists and other healthcare professionals in determining whether a patient has an indwelling urinary catheter when a catheter-associated urinary tract infection is suspected. Currently, data on indwelling urinary catheters is not consistently captured in the electronic medical record in structured format and thus cannot be reliably extracted for clinical and research purposes. We developed a lexicon of terms related to indwelling urinary catheters and urinary symptoms based on domain knowledge, prior experience in the field, and review of medical notes. A reference standard of 1595 randomly selected documents from inpatient admissions was annotated by human reviewers to identify all positively and negatively asserted concepts related to indwelling urinary catheters. We trained a natural language processing pipeline based on the V3NLP framework using 1050 documents and tested on 545 documents to determine agreement with the human reference standard. Metrics reported are positive predictive value and recall. The lexicon contained 590 terms related to the presence of an indwelling urinary catheter in various categories including insertion, care, change, and removal of urinary catheters and 67 terms for urinary symptoms. Nursing notes were the most frequent inpatient note titles in the reference standard document corpus; these also yielded the highest number of positively asserted concepts with respect to urinary catheters. Comparing the performance of the natural language processing pipeline against the human reference standard, the overall recall was 75% and positive predictive value was 99% on the training set; on the testing set, the recall was 72% and positive predictive value was 98%. The performance on extracting urinary symptoms (including fever) was high with recall and precision greater than 90%. We have shown that it is possible to identify the presence of an indwelling urinary catheter and urinary symptoms from the free text of electronic medical notes from inpatients using natural language processing. These are two key steps in developing automated protocols to assist humans in large-scale review of patient charts for catheter-associated urinary tract infection. The challenges associated with extracting indwelling urinary catheter-related concepts also inform the design of electronic medical record templates to reliably and consistently capture data on indwelling urinary catheters. Published by Elsevier Inc.
Mahan, Angel F; McEvoy, Matthew D; Gravenstein, Nikolaus
2016-04-01
In modern practice, real-time ultrasound guidance is commonly employed for the placement of internal jugular vein catheters. With a new tool, such as ultrasound, comes the opportunity to refine and further optimize the ultrasound view during jugular vein catheterization. We describe jugular vein access techniques and use the long-axis view as an alternative to the commonly employed short-axis cross-section view for internal jugular vein access and cannulation. The long-axis ultrasound-guided internal jugular vein approach for internal jugular vein cannulation is a useful alternative technique that can provide better needle tip and guidewire visualization than the more traditional short-axis ultrasound view.
Vertebral Artery Origin Stent Placement Using the Dual Lumen Qureshi-Jiao Guidecatheter
Qureshi, Adnan I.; Wang, Yabing; Afzal, Mohammad Rauf; Jiao, Liqun
2017-01-01
Objective We report the first experience with a new dual lumen guide catheter with lumen A with curved tip designed for delivery of stent and angioplasty catheters and lumen B with side exit for coaxial placement of stiff 0.014 inch wire. Methods We prospectively determined technical success, intended procedure (stent delivery at target lesion and a final residual stenosis <30%) completed without a need for a different catheter, and technical ease, intended procedure completed without ≥3 unsuccessful attempts in patients with symptomatic vertebral artery origin stenosis. Vertebral artery origin was classified as type A if originated from ascending segment and type B if originated from an arch or horizontal segment of subclavian artery. Results The mean age of the four treated patients was 66.2 years (range 64–68 years). The mean percentage of vertebral artery origin stenosis was 82.7% (range 60–92%). The origin of vertebral artery from subclavian artery was classified as type A and type B origins in two patients each. The dual lumen catheter was advanced over an exchange length of 0.035 inch glide wire in one patient and directly through transfemoral insertion in three patients. Technical success and technical ease was achieved in all four procedures. Post procedure residual stenosis was 6% (range 5–7%). The primary operator rated the performance of guide catheter as superior compared with another catheter used in such procedures. Conclusion The present study demonstrates the feasibility of performing stent placement for vertebral artery origin stenosis by using a dual lumen catheter with superior performance. PMID:29445438
Losey, Aaron D.; Lillaney, Prasheel; Martin, Alastair J.; Cooke, Daniel L.; Wilson, Mark W.; Thorne, Bradford R. H.; Sincic, Ryan S.; Arenson, Ronald L.; Saeed, Maythem
2014-01-01
Purpose To compare in vitro navigation of a magnetically assisted remote-controlled (MARC) catheter under real-time magnetic resonance (MR) imaging with manual navigation under MR imaging and standard x-ray guidance in endovascular catheterization procedures in an abdominal aortic phantom. Materials and Methods The 2-mm-diameter custom clinical-grade microcatheter prototype with a solenoid coil at the distal tip was deflected with a foot pedal actuator used to deliver 300 mA of positive or negative current. Investigators navigated the catheter into branch vessels in a custom cryogel abdominal aortic phantom. This was repeated under MR imaging guidance without magnetic assistance and under conventional x-ray fluoroscopy. MR experiments were performed at 1.5 T by using a balanced steady-state free precession sequence. The mean procedure times and percentage success data were determined and analyzed with a linear mixed-effects regression analysis. Results The catheter was clearly visible under real-time MR imaging. One hundred ninety-two (80%) of 240 turns were successfully completed with magnetically assisted guidance versus 144 (60%) of 240 turns with nonassisted guidance (P < .001) and 119 (74%) of 160 turns with standard x-ray guidance (P = .028). Overall mean procedure time was shorter with magnetically assisted than with nonassisted guidance under MR imaging (37 seconds ± 6 [standard error of the mean] vs 55 seconds ± 3, P < .001), and time was comparable between magnetically assisted and standard x-ray guidance (37 seconds ± 6 vs 44 seconds ± 3, P = .045). When stratified by angle of branch vessel, magnetic assistance was faster than nonassisted MR guidance at turns of 45°, 60°, and 75°. Conclusion In this study, a MARC catheter for endovascular navigation under real-time MR imaging guidance was developed and tested. For catheterization of branch vessels arising at large angles, magnetically assisted catheterization was faster than manual catheterization under MR imaging guidance and was comparable to standard x-ray guidance. © RSNA, 2014 Online supplemental material is available for this article. PMID:24533872
Werner, Gerald S; Schofer, Joachim; Sievert, Horst; Kugler, Chad; Reifart, Nicolaus J
2011-06-01
The major challenge for the interventional treatment of chronic total coronary occlusion (CTO) is a low primary success rate. A common problem is the passage of the recanalisation wire into a subintimal position. New devices, which were evaluated in the first multicentre study in CTOs resistant to a conventional wire approach, may help to facilitate a controlled re-entry into the true lumen. The aim of this study was to assess the safety and efficacy of this approach, with successful true lumen distal wire passage as the primary endpoint. Forty-two patients were enrolled in four centres with high expertise in PCI for CTOs. All CTOs were of at least three months duration, and were initially attempted with dedicated recanalisation wires. After failure to pass or creation of a subintimal dissection, the BridgePoint devices were applied, consisting of a ball-tipped catheter (CrossBoss) to pass the proximal occlusion cap, and a flat-shaped balloon catheter (Stingray catheter) to be inflated within the subintimal space to guide the re-entry into the true vessel lumen with a special wire (Stingray guidewire). The primary endpoint was met in 67% of all patients. A higher success rate seemed to be possible when all devices were used in sequenced beginning with the CrossBoss, and in the case of a subintimal passage, followed by the Stingray. True lumen re-entry failed because of the loss of distally contrast filling and thus loss of a target for re-entry, and by a failure to advance the Stingray balloon far enough distal and parallel to the distal lumen. There were no severe device related complications. In patients with complex CTOs referred to dedicated centres with high experience in CTOs, these results demonstrate the potential of a guided re-entry from a subintimal wire position by use of the BridgePoint devices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beaulieu, L.; Racine, E.; Boutaleb, S.
In modern brachytherapy, application of large doses of ionizing radiation in a limited number of fractions is frequent. Furthermore, as with any surgical procedures, brachytherapy is subject to learning curve effects. In this context, there could be advantages of integrating real-time tracking of needles/catheters to existing protocols given the recent prominent advances in tracking technologies. In this work, we review the use of an electromagnetic tracking system (EMTS) based on the second generation Aurora® Planar Field Generator (Northern Digital Inc) and custom design needles (Philips Healthcare) for brachytherapy applications. The position and orientation information is obtained from 5 degrees ofmore » freedom sensors. Basic system performance characterization is performed in well-controlled conditions to establish accuracy and reproducibility as well as potential interference from standard brachytherapy equipment. The results show that sensor locations can be tracked to within 0.04mm (la) when located within 26cm of the generator. Orientation accuracy of the needle remained within ±1° in the same region, but rose quickly at larger distances. The errors on position and orientation strongly dependent the sensor position in the characterization volume (500×500×500mm{sup 3}). The presence of an ultrasound probe was shown to have negligible effects on tracking accuracy. The use of EMTS for automatic catheter/applicator reconstruction was also explored. Reconstruction time was less than 10 sec/channel and tips identification was within 0.69±0.29mm of the reference values. Finally, we demonstrate that hollow needle designs with special EM adaptation also allow for real-time seed drop position estimation. In phantom experiments showed that drop positions were on average within 1.6±0.9mm of the reference position measured from μCT. Altogether, EMTS offer promising benefits in a wide range of brachytherapy applications.« less
Hiroshima, Yuki; Tajima, Katsushi; Shiono, Yousuke; Suzuki, Ikuko; Kohno, Kei; Kato, Yuichi; Shunji, Kawamura; Kato, Takeo
2012-01-01
Cardiac tamponade caused by perforation is a rare but potentially lethal complication of central venous catheter (CVC) insertion. We herein report a case of cardiac perforation associated with the use of a soft J-tipped guide wire. Twenty minutes after the insertion of a CVC, the patient developed unexpected cardiac arrest. An autopsy revealed 400 mL of pericardial blood. The right ventricular wall was 1 mm thick with about 10 myocyte layers, which is one-third that of the normal heart. A histological analysis revealed widespread fatty infiltration of the right ventricular wall (right ventricular lipomatosis).
Boo, Nem Yun; Suhaida, Abdul Rahman; Rohana, Jaafar
2015-01-01
INTRODUCTION This case-control study aimed to determine whether catheter use was significantly associated with coagulase-negative staphylococci (CoNS) colonisation and/or sepsis in neonates. METHODS Weekly swabs of the nose, umbilicus, rectum, wounds, eye discharge and intravenous catheter tips (after removal) of infants admitted to the neonatal intensive care unit of Universiti Kebangsaan Malaysia Medical Centre, Malaysia, were cultured. CoNS sepsis was diagnosed if pure growth of CoNS was cultured from the peripheral blood specimen of symptomatic infants. For each infant with CoNS colonisation or sepsis, a control infant was retrospectively and randomly selected from unaffected infants in the ward. Multivariate analyses were performed to determine whether catheter use was a significant risk factor. RESULTS CoNS colonisation was detected in 113 (8.7%) infants. CoNS sepsis was found in 12 (10.6%) infants with CoNS colonisation and 7 (0.6%) infants without CoNS colonisation. Multivariate analysis showed that the following were significantly associated with CoNS colonisation: conjunctivitis (adjusted odds ratio [OR] 8.2, 95% confidence interval [CI] 1.9–34.8, p = 0.005); central venous catheters (adjusted OR 5.8, 95% CI 1.9–17.8, p = 0.002); and nasopharyngeal and/or oral suctioning more than twice in the 48 hours before positive culture (adjusted OR 7.3, 95% CI 3.3–16.2, p < 0.001). Exposure to frequent nasopharyngeal and/or oral suctioning (adjusted OR 20.8, 95% CI 3.5–125.3, p = 0.001) was the only significant factor associated with CoNS sepsis. CONCLUSION Infants requiring more than two nasopharyngeal and/or oral suctions in the previous 48 hours were found to have a higher risk of developing CoNS colonisation and sepsis. PMID:25532513
Tarai, B; Das, P; Kumar, D; Budhiraja, S
2012-01-01
Paired blood culture (PBC) is uncommon practice in hospitals in India, leading to delayed and inadequate diagnosis. Also contamination remains a critical determinant in hampering the definitive diagnosis. To establish the need of PBC over single blood culture (SBC) along with the degree of contamination, this comparative retrospective study was initiated. We processed 2553 PBC and 4350 SBC in BacT/ALERT 3D (bioMerieux) between October 2010 and June 2011. The positive cultures were identified in VITEK 2 Compact (bioMerieux). True positivity and contaminants were also analyzed in 486 samples received from catheter and peripheral line. Out of 2553 PBC samples, positivity was seen in 350 (13.70%). In 4350 SBC samples, positivity was seen in 200 samples (4.59%). In PBC true pathogens were 267 (10.45%) and contaminants were 83 (3.25%), whereas in SBC 153 (3.51%) were true positives and contaminants were 47 (1.08%). Most of the blood cultures (99.27 %) grew within 72 h and 95.8% were isolated within 48 h. In 486 PBCs received from catheter/periphery (one each), catheter positivity was found in 85 (true positives were 48, false positives 37). In peripheral samples true positives were 50 and false positives were 8. Significantly higher positive rates were seen in PBCs compared with SBCs. Automated blood culture and identification methods significantly reduced the time required for processing of samples and also facilitated yield of diverse/rare organisms. Blood culture from catheter line had higher false positives than peripheral blood culture. Thus every positive result from a catheter must be correlated with clinical findings and requires further confirmation.
Salerno, Sergio; Tudisca, Chiara; Murmura, Elena; Matranga, Domenica; La Tona, Giuseppe; Lo Re, Giuseppe; Lo Casto, Antonio
2017-05-01
Umbilical Venous Catheter (UVC) are commonly used in neonatal period; they can be not correctly positioned and could be associated with complications. The purpose of this article is to suggest a flow-chart to evaluate the placement of UVC, testing it in young radiologists-in-training. We developed a simple flow-chart to asses, steps by step, UVC placement considering its course and tip location (ideally placed in the atriocaval junction). We tested the flow-chart impact asking to 20 residents to evaluate the placement of 10 UVC before and after they familiarized with the flow-chart and the anatomical findings of a newborn. The agreement among the 20 students was evaluated too. The number of correct characterizations was different due to the administration of the flow-chart. One hundred and six correct UVC assessments at the beginning switched to 196 after the administration of the flow-chart (p = 0.0001). The observed agreement among the twenty radiology residents was statistically significant, both before (kappa = 0.41, p < 0.001) and after (kappa = 0.37, p < 0.001) the flow-chart administration. The developed flow-chart demonstrated to be useful in increasing residents performance in UVC placement assessment.
Catheter tracking using continuous radial MRI.
Rasche, V; Holz, D; Köhler, J; Proksa, R; Röschmann, P
1997-06-01
The guidance of minimally invasive procedures may become a very important future application of MRI. The guidance of interventions requires images of the anatomy as well as the information of the position of invasive devices used. This paper introduces continuous radial MRI for the simultaneous acquisition of the anatomic MR image and the position of one or more small RF-coils (mu-coils), which can be mounted on invasive devices such as catheters or biopsy needles. This approach allows the in-plane tracking of an invasive device without any prolongation of the overall acquisition time. The extension to three-dimensional position tracking is described. Phantom studies are presented demonstrating the capability of this technique for real-time automatic adjustment of the slice position to the current catheter position with a temporal resolution of 100 ms. Simultaneously the in-plane catheter position is depicted in the actually acquired MR image during continuous scanning.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poulin, E; Racine, E; Beaulieu, L
2014-06-15
Purpose: In high dose rate brachytherapy (HDR-B), actual catheter reconstruction protocols are slow and errors prompt. The purpose of this study was to evaluate the accuracy and robustness of an electromagnetic (EM) tracking system for improved catheter reconstruction in HDR-B protocols. Methods: For this proof-of-principle, a total of 10 catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a Philips-design 18G biopsy needle (used as an EM stylet) and the second generation Aurora Planar Field Generator from Northern Digital Inc. The Aurora EM system exploits alternating current technology and generates 3D points at 40 Hz. Phantomsmore » were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical CT system with a resolution of 0.089 mm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, 5 catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 seconds or less. This would imply that for a typical clinical implant of 17 catheters, the total reconstruction time would be less than 3 minutes. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.92 ± 0.37 mm and 1.74 ± 1.39 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be significantly more accurate (unpaired t-test, p < 0.05). A mean difference of less than 0.5 mm was found between successive EM reconstructions. Conclusion: The EM reconstruction was found to be faster, more accurate and more robust than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators. We would like to disclose that the equipments, used in this study, is coming from a collaboration with Philips Medical.« less
Ghata, Narugopal; Aldredge, Ralph C.; Bec, Julien; Marcu, Laura
2015-01-01
SUMMARY Optical techniques including fluorescence lifetime spectroscopy have demonstrated potential as a tool for study and diagnosis of arterial vessel pathologies. However, their application in the intravascular diagnostic procedures has been hampered by the presence of blood hemoglobin that affects the light delivery to and the collection from the vessel wall. We report a computational fluid dynamics model that allows for the optimization of blood flushing parameters in a manner that minimizes the amount of saline needed to clear the optical field of view and reduces any adverse effects caused by the external saline jet. A 3D turbulence (k−ω) model was employed for Eulerian–Eulerian two-phase flow to simulate the flow inside and around a side-viewing fiber-optic catheter. Current analysis demonstrates the effects of various parameters including infusion and blood flow rates, vessel diameters, and pulsatile nature of blood flow on the flow structure around the catheter tip. The results from this study can be utilized in determining the optimal flushing rate for given vessel diameter, blood flow rate, and maximum wall shear stress that the vessel wall can sustain and subsequently in optimizing the design parameters of optical-based intravascular catheters. PMID:24953876
NASA Astrophysics Data System (ADS)
Heneweer, Carola; Siggelkow, Markus; Helle, Michael; Petzina, Rainer; Wulff, Asmus; Schaefer, Joost P.; Berndt, Rouven; Rusch, Rene; Wedel, Thilo; Klaws, Guenther; Müller-Gerbl, Magdalena; Röcken, Christoph; Jansen, Olav; Lutter, Georg; Cremer, Joachim; Groß, Justus
2015-02-01
Stenosis and occlusion of the superficial femoral artery (SFA) are most common in arterial occlusive disease. There are numerous interventional, surgical, and combined approaches to reconstitute maximum blood supply to the lower limb; however, despite intense clinical research, the long-term success rates are still poor. We present the first results with a catheter prototype for laser-based minimal invasive endarterectomy, called laser scoop desobliteration (LSD). The tip of a glass fiber containing a catheter was modified with a spatula head design and connected to an ultraviolet laser. It was tested in cadavers fixed with the Thiel embalming technique preserving tissue consistency, flexibility, and plasticity. After longitudinal arteriotomy of the SFA, a circular dissection between media and adventitia was performed. Then the LSD catheter was inserted and propagated with a progress of 1 mm/s. Afterward, the atheroma core, which showed a plain surface without substantial attaching tissue debris, was removed. Histological examination of the vessel wall showed that the dissection was performed at the media/adventitia interface. In summary, the constructed LSD catheter allowed a rapid and easy way to perform an endarterectomy, thereby offering an innovative approach in the treatment of chronic occluded SFA.
Tanguy, Michèle; Seguin, Philippe; Laviolle, Bruno; Desbordes, Laurent; Mallédant, Yannick
2005-05-01
To assess clinical safety and accuracy of qualitative blood culture drawn through the hub for ruling out catheter-related infection (CRI). Prospective observational study in a surgical intensive care unit. All patients with sepsis of unknown origin and possibly due to a CRI. Blood culture drawn through a central venous catheter (CVC) just before the catheter was cultured. In 126 patients we investigated 135 cases of sepsis of unknown origin. Using a clinical and bacteriological approach as the reference, the performance of the CVC blood culture was evaluated by the calculation of sensitivity, specificity, and positive and negative predictive values. When CVC blood culture was positive, the time to positivity was considered. Using standard definitions, seven CRIs were diagnosed. CVC blood culture identified five CRIs including the three episodes of catheter-related bacteremia. The method missed two coagulase-negative staphylococcus CRIs without bacteremia. Thirteen false-positive results occurred, including seven bacteremias from a distant source. The CVC blood culture had a sensitivity of 71% (CI 30-95%), specificity of 90% (CI 83-94%), negative predictive value of 98% (CI 93-100%), and positive predictive value of 28% (CI 11-54%). In cases of catheter-related bacteremia the time to positivity of CVC blood culture was 24 h or less. Negative CVC blood culture at 24 h seems useful for management of CVC in selected critically ill surgical patients developing a clinical sepsis. The subsequent risk of catheter-related bacteremia cannot be excluded advocating for an uninterrupted clinical and bacteriological survey.
Persistent Atrial Fibrillation Ablation using the Tip-Versatile Ablation Catheter.
Davies, Edward J; Clayton, Ben; Lines, Ian; Haywood, Guy A
2016-07-01
The mechanisms by which persistent atrial fibrillation (PsAF) develops are incompletely understood. Consequently, the optimal strategy for the ablative management of PsAF remains debated. Current methods are often time consuming, complex and non-reproducible. We assessed the Tip-Versatile Ablation Catheter (T-VAC) technique, a rapidly delivered, empirical technique based on the box-set concept using duty-cycled linear catheter ablation technology. Forty-four procedures in 40 patients undergoing PsAF ablation with the novel technique were prospectively entered onto a database: 27 de novo. Primary endpoint was freedom from arrhythmia at over two-year follow-up. Secondary endpoints were time to first arrhythmia recurrence, freedom from atrial fibrillation (AF) on and off antiarrhythmic drugs (AAD), procedural and fluoroscopy duration and complication rate. At mean follow-up of 33 months, absolute freedom from arrhythmia recurrence was 45% in the de novo group. Overall, at 33 (IQR 24-63) months, 60% of de novo patients were in sustained normal sinus rhythm and a further 15% reported only occasional paroxysms of AF at long-term follow-up. Procedure time was 192±25 mins, total energy delivered 2239±883s and fluoroscopy time was 60±10mins. In selected patients with persistent AF, a long-term rate of 60% arrhythmia free survival off AAD can be achieved using this novel T-VAC technique. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Kleman, Mandi E; Estrada, Amara H; Maisenbacher, Herbert W; Prošek, Robert; Pogue, Brandon; Shih, Andre; Paolillo, Joseph A
2012-01-01
Subvalvular aortic stenosis (SAS) is one of the most common congenital cardiac malformations in dogs. Unfortunately, the long term success rate and survival data following either open heart surgery or catheter based intervention has been disappointing in dogs with severe subaortic stenosis. Medical therapy is currently the only standard recommended treatment option. A cutting balloon dilation catheter has been used successfully for resistant coronary artery and peripheral pulmonary arterial stenoses in humans. This catheter is unique in that it has the ability to cut, or score, the stenotic region prior to balloon dilatation of the stenosis. The use of cutting balloon valvuloplasty combined with high pressure valvuloplasty for dogs with severe subaortic stenosis has recently been reported to be a safe and feasible alternative therapeutic option. The following report describes this technique, outlines the materials required, and provides some 'tips' for successful percutaneous subaortic balloon valvuloplasty. Copyright © 2012 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Langer, Jessica M.; Cohen, Raphael M.; Berns, Jeffrey S.
Purpose: Over-the-wire exchange of tunneled dialysis catheters is the standard of care per K/DOQI guidelines for treating catheter-related bacteremia. However, Gram-positive bacteremia, specifically with staphylococcus species, may compromise over-the-wire exchange due to certain biological properties. This study addressed the effectiveness of over-the-wire exchange of staphylococcus-infected tunneled dialysis catheters compared with non-staphylococcus-infected tunneled dialysis catheters. Methods: Patients who received over-the-wire exchange of their tunneled dialysis catheter due to documented or suspected bacteremia were identified from a QA database. Study patients (n = 61) had positive cultures for Staphylococcus aureus, Staphylococcus epidermidis, or coagulase-negative staphylococcus not otherwise specified. Control patients (n =more » 35) received over-the-wire exchange of their tunneled dialysis catheter due to infection with any organism besides staphylococcus. Overall catheter survival and catheter survival among staphylococcal species were assessed. Results: There was no difference in tunneled dialysis catheter survival between study and control groups (P = 0.46). Median survival time was 96 days for study catheters and 51 days for controls; survival curves were closely superimposed. There also was no difference among the three staphylococcal groups in terms of catheter survival (P = 0.31). The median time until catheter removal was 143 days for SE, 67 days for CNS, and 88 days for SA-infected catheters. Conclusions: There is no significant difference in tunneled dialysis catheter survival between over-the-wire exchange of staphylococcus-infected tunneled dialysis catheters and those infected with other organisms.« less
Eddinger, Kelly A; Rondon, Eric S; Shubayev, Veronica I; Grafe, Marjorie R; Scadeng, Miriam; Hildebrand, Keith R; Page, Linda M; Malkmus, Shelle A; Steinauer, Joanne J; Yaksh, Tony L
2016-08-01
Intrathecal infusion of opioids in dogs, sheep, and humans produces local space-occupying masses. To develop a small-animal model, the authors examined effects of intrathecal catheterization and morphine infusion in guinea pigs. Under isoflurane, polyethylene or polyurethane catheters were advanced from the cisterna magna to the lumbar enlargement. Drugs were delivered as a bolus through the externalized catheter or continuously by subcutaneous minipumps. Hind paw withdrawal to a thermal stimulus was assessed. Spinal histopathology was systematically assessed in a blinded fashion. To assist in determining catheter placement, ex vivo images were obtained using magnetic resonance imaging in several animals. Canine spinal tissue from previous intrathecal morphine studies was analyzed in parallel. (1) Polyethylene (n = 30) and polyurethane (n = 25) catheters were implanted in the lumbar intrathecal space. (2) Bolus intrathecal morphine produced a dose-dependent (20 to 40 μg/10 μl) increase in thermal escape latencies. (3) Absent infusion, a catheter-associated distortion of the spinal cord and a fibrotic investment were noted along the catheter tract (polyethylene > polyurethane). (4) Intrathecal morphine infusion (25 mg/ml/0.5 μl/h for 14 days) resulted in intrathecal masses (fibroblasts, interspersed collagen, lymphocytes, and macrophages) arising from meninges proximal to the catheter tip in both polyethylene- and polyurethane-catheterized animals. This closely resembles mass histopathology from intrathecal morphine canine studies. Continuous intrathecal infusion of morphine leads to pericatheter masses that morphologically resemble those observed in dogs and humans. This small-animal model may be useful for studying spinal drug toxicology in general and the biology of intrathecal granuloma formation in particular.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sakamoto, Noriaki, E-mail: nosakamoto@hotmail.co.jp; Arai, Yasuaki, E-mail: arai-y3111@mvh.biglobe.ne.jp; Takeuchi, Yoshito, E-mail: yostakeu@ncc.go.jp
2010-10-15
The purpose of this study was to assess the technical success rate and adverse events (AEs) associated with ultrasound (US)-guided radiological placement (RP) of a central venous port (CVP) via the subclavian vein (SCV). Between April 2006 and May 2007, a total of 500 US-guided RPs of a CVP via the SCV were scheduled in 486 cancer patients (mean age {+-} SD, 54.1 {+-} 18.1 years) at our institute. Referring to the interventional radiology report database and patients' records, technical success rate and AEs relevant to CVP placement were evaluated retrospectively. The technical success rate was 98.6% (493/500). AEs occurredmore » in 26 cases (5.2%) during follow-up (range, 1-1080 days; mean {+-} SD, 304.0 {+-} 292.1 days). AEs within 24 h postprocedure occurred in five patients: pneumothorax (n = 2), arterial puncture (n = 1), hematoma formation at the pocket site (n = 2), and catheter tip migration into the internal mammary vein (n = 1). There were seven early AEs: hematoma formation at the pocket site (n = 2), fibrin sheath formation around the indwelling catheter (n = 2), and catheter-related infections (n = 3). There were 13 delayed AEs: catheter-related infections (n = 7), catheter detachments (n = 3), catheter occlusion (n = 1), symptomatic thrombus in the SCV (n = 1), and catheter migration (n = 1). No major AEs, such as procedure-related death, air embolism, or events requiring surgical intervention, were observed. In conclusion, US-guided RP of a CVP via the SCV is highly appropriate, based on its high technical success rate and the limited number of AEs.« less
Polisena, Julie; Forster, Alan J; Cimon, Karen; Rabb, Danielle
2013-10-10
Post-marketing surveillance (PMS) may identify rare serious incidents or adverse events due to the long-term use of a medical device, which was not captured in the pre-market process. Percutaneous transluminal coronary angioplasty (PTCA) is a non-surgical procedure that uses a balloon-tipped catheter to enlarge a narrowed artery. In 2011, 1,942 adverse event reports related to the use of PTCA catheters were submitted to the FDA by the manufacturers, an increase from the 883 reported in 2008. The primary research objective is to conduct a systematic review of the published and grey literature published between 2007 and 2012 for the frequency of incidents, adverse events and malfunctions associated with the use of PTCA catheters in patients with coronary artery disease (CAD). Grey literature has not been commercially published. We searched MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials and PubMed for medical literature on PMS for PTCA catheters in patients with CAD published between January 2007 and July 2012. We also searched the grey literature. This review included 11 studies. The in-hospital adverse events reported were individual cases of myocardial infarction and hematoma. In studies of patients with coronary perforation, more patients with balloon angioplasty were identified compared with patients who required stenting. Our systematic review illustrates that the volume and quality of PMS studies associated with the use of PTCA catheters in patients with CAD are low in the published and grey literature, and may not be useful sources of information for decisions on safety. In most studies, the objectives were not to monitor the long-term safety of the use of PTCA catheters in clinical practice. Future studies can explore the strengths and limitations of PMS databases administered by regulatory authorities.
Carlesse, Fabianne; Amaral, Anna-Paula C; Gonçalves, Sarah S; Xafranski, Hemilio; Lee, Maria-Lucia M; Zecchin, Victor; Petrilli, Antonio S; Al-Hatmi, Abdullah M; Hagen, Ferry; Meis, Jacques F; Colombo, Arnaldo L
2017-01-01
Fusarium species are widely spread in nature as plant pathogens but are also able to cause opportunistic fungal infections in humans. We report a cluster of Fusarium oxysporum bloodstream infections in a single pediatric cancer center. All clinical and epidemiological data related to an outbreak involving seven cases of fungemia by Fusarium oxysporum during October 2013 and February 2014 were analysed. All cultured isolates ( n = 14) were identified to species level by sequencing of the TEF1 and RPB2 genes. Genotyping of the outbreak isolates was performed by amplified fragment length polymorphism fingerprinting. In a 5-month period 7 febrile pediatric cancer patients were diagnosed with catheter-related Fusarium oxysporum bloodstream infections. In a time span of 11 years, only 6 other infections due to Fusarium were documented and all were caused by a different species, Fusarium solani . None of the pediatric cancer patients had neutropenia at the time of diagnosis and all became febrile within two days after catheter manipulation in a specially designed room. Extensive environmental sampling in this room and the hospital did not gave a clue to the source. The outbreak was terminated after implementation of a multidisciplinary central line insertion care bundle. All Fusarium strains from blood and catheter tips were genetically related by amplified fragment length polymorphism fingerprinting. All patients survived the infection after prompt catheter removal and antifungal therapy. A cluster with, genotypical identical, Fusarium oxysporum strains infecting 7 children with cancer, was most probably catheter-related. The environmental source was not discovered but strict infection control measures and catheter care terminated the outbreak.
NASA Astrophysics Data System (ADS)
Liu, Shengnan; Eggermont, Jeroen; Wolterbeek, Ron; Broersen, Alexander; Busk, Carol A. G. R.; Precht, Helle; Lelieveldt, Boudewijn P. F.; Dijkstra, Jouke
2016-12-01
Intravascular optical coherence tomography (IVOCT) is an imaging technique that is used to analyze the underlying cause of cardiovascular disease. Because a catheter is used during imaging, the intensities can be affected by the catheter position. This work aims to analyze the effect of the catheter position on IVOCT image intensities and to propose a compensation method to minimize this effect in order to improve the visualization and the automatic analysis of IVOCT images. The effect of catheter position is modeled with respect to the distance between the catheter and the arterial wall (distance-dependent factor) and the incident angle onto the arterial wall (angle-dependent factor). A light transmission model incorporating both factors is introduced. On the basis of this model, the interaction effect of both factors is estimated with a hierarchical multivariant linear regression model. Statistical analysis shows that IVOCT intensities are significantly affected by both factors with p<0.001, as either aspect increases the intensity decreases. This effect differs for different pullbacks. The regression results were used to compensate for this effect. Experiments show that the proposed compensation method can improve the performance of the automatic bioresorbable vascular scaffold strut detection.
Berger, Itay; Gil Margolis, Merav; Nahum, Elhanan; Dagan, Ovdi; Levy, Itzhak; Kaplan, Eytan; Shostak, Eran; Shmuelov, Esther; Schiller, Ofer; Kadmon, Gili
2018-05-01
Arterial catheters may serve as an additional source for blood cultures in children when peripheral venipuncture is challenging. The aim of the study was to evaluate the accuracy of cultures obtained through indwelling arterial catheters for the diagnosis of bloodstream infections in critically ill pediatric patients. Observational and comparative. General and cardiac ICUs of a tertiary, university-affiliated pediatric medical center. The study group consisted of 138 patients admitted to the general or cardiac PICU in 2014-2015 who met the following criteria: presence of an indwelling arterial catheter and indication for blood culture. Blood was drawn by peripheral venipuncture and through the arterial catheter for each patient and sent for culture (total 276 culture pairs). Two specialists blinded to the blood source evaluated each positive culture to determine if the result represented true bloodstream infection or contamination. The sensitivity, specificity, and positive and negative predictive values of the arterial catheter and peripheral cultures for the diagnosis of bloodstream infection were calculated. Of the 56 positive cultures, 41 (15% of total samples) were considered diagnostic of true bloodstream infection. In the other 15 (5%), the results were attributed to contamination. The rate of false-positive results was higher for arterial catheter than for peripheral venipuncture cultures (4% vs 1.5%) but did not lead to prolonged unnecessary antibiotic treatment. On statistical analysis, arterial catheter blood cultures had high sensitivity (85%) and specificity (95%) for the diagnosis of true bloodstream infection, with comparable performance to peripheral blood cultures. Cultures of arterial catheter-drawn blood are reliable for the detection of bloodstream infection in PICUs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dise, J; Liang, X; Lin, L
Purpose: To evaluate an automatic interstitial catheter digitization algorithm that reduces treatment planning time and provide means for adaptive re-planning in HDR Brachytherapy of Gynecologic Cancers. Methods: The semi-automatic catheter digitization tool utilizes a region growing algorithm in conjunction with a spline model of the catheters. The CT images were first pre-processed to enhance the contrast between the catheters and soft tissue. Several seed locations were selected in each catheter for the region growing algorithm. The spline model of the catheters assisted in the region growing by preventing inter-catheter cross-over caused by air or metal artifacts. Source dwell positions frommore » day one CT scans were applied to subsequent CTs and forward calculated using the automatically digitized catheter positions. This method was applied to 10 patients who had received HDR interstitial brachytherapy on an IRB approved image-guided radiation therapy protocol. The prescribed dose was 18.75 or 20 Gy delivered in 5 fractions, twice daily, over 3 consecutive days. Dosimetric comparisons were made between automatic and manual digitization on day two CTs. Results: The region growing algorithm, assisted by the spline model of the catheters, was able to digitize all catheters. The difference between automatic and manually digitized positions was 0.8±0.3 mm. The digitization time ranged from 34 minutes to 43 minutes with a mean digitization time of 37 minutes. The bulk of the time was spent on manual selection of initial seed positions and spline parameter adjustments. There was no significance difference in dosimetric parameters between the automatic and manually digitized plans. D90% to the CTV was 91.5±4.4% for the manual digitization versus 91.4±4.4% for the automatic digitization (p=0.56). Conclusion: A region growing algorithm was developed to semi-automatically digitize interstitial catheters in HDR brachytherapy using the Syed-Neblett template. This automatic digitization tool was shown to be accurate compared to manual digitization.« less
SU-F-P-42: “To Navigate, Or Not to Navigate: HDR BT in Recurrent Spine Lesions”
DOE Office of Scientific and Technical Information (OSTI.GOV)
Voros, L; Cohen, G; Zaider, M
Purpose: We compare the accuracy of HDR catheter placement for paraspinal lesions using O-arm CBCT imaging combined with StealthStation navigation and traditional fluoroscopically guided catheter placement. Methods: CT and MRI scans were acquired pre-treatment to outline the lesions and design treatment plans (pre-plans) to meet dosimetric constrains. The pre-planned catheter trajectories were transferred into the StealthStation Navigation system prior to the surgery. The StealthStation is an infra red (IR) optical navigation system used for guidance of surgical instruments. An intraoperative CBCT scan (O-arm) was acquired with reference IR optical fiducials anchored onto the patient and registered with the preplan imagemore » study to guide surgical instruments in relation to the patients’ anatomy and to place the brachytherapy catheters along the pre-planned trajectories. The final treatment plan was generated based on a 2nd intraoperative CBCT scan reflecting achieved implant geometry. The 2nd CBCT was later registered with the initial CT scan to compare the preplanned dwell positions with actual dwell positions (catheter placements). Similar workflow was used in placement of 8 catheters (1 patient) without navigation, but under fluoroscopy guidance in an interventional radiology suite. Results: A total of 18 catheters (3 patients) were placed using navigation assisted surgery. Average displacement of 0.66 cm (STD=0.37cm) was observed between the pre-plan source positions and actual source positions in the 3 dimensional space. This translates into an average 0.38 cm positioning error in one direction including registration errors, digitization errors, and the surgeons ability to follow the planned trajectory. In comparison, average displacement of non-navigated catheters was 0.50 cm (STD=0.22cm). Conclusion: Spinal lesion HDR brachytherapy planning is a difficult task. Catheter placement has a direct impact on target coverage and dose to critical structures. While limited to a handful of patients, our experience shows navigation and fluoroscopy guided placement yield similar results.« less
Borghi, Battista; Agnoletti, Vanni; Ricci, Alessandro; van Oven, Hanna; Montone, Nicoletta; Casati, Andrea
2004-05-01
We evaluated the effects of turning the tip of the Tuohy needle 45 degrees toward the operative side before threading the epidural catheter (45 degrees -rotation group, n = 24) as compared to a conventional insertion technique with the tip of the Tuohy needle oriented at 90 degrees cephalad (control group, n = 24) on the distribution of 10 mL of 0.75% ropivacaine with 10 microg sufentanil in 48 patients undergoing total hip replacement. The catheter was introduced 3 to 4 cm beyond the tip of the Tuohy needle. A blinded observer recorded sensory and motor blocks on both sides, quality of analgesia, and volumes of local anesthetic used during the first 48 h of patient-controlled epidural analgesia. Readiness to surgery required 21 +/- 6 min in the control group and 17 +/- 7 min in the 45 degree-rotation group (P > 0.50). The maximum sensory level reached on the operative side was T10 (T10-7) in the control group and T9 (T10-6) in the 45 degree-rotation group (P > 0.50); whereas the maximum sensory level reached on the nonoperative side was T10 (T12-9) in the control group and L3 (L5-T12) in the 45 degree-rotation group (P = 0.0005). Complete motor blockade of the operative limb was achieved earlier in the 45 degree-rotation than in the control group, and motor block of the nonoperative side was more intense in patients in the control group. Two-segment regression of sensory level on the surgical side was similar in the two groups, but occurred earlier on the nonoperative side in the 45 degree-rotation group (94 +/- 70 min) than in the control group (178 +/- 40 min) (P = 0.0005). Postoperative analgesia was similar in the 2 groups, but the 45 degree-rotation group consumed less local anesthetic (242 +/- 35 mL) than the control group (297 +/- 60 mL) (P = 0.0005). We conclude that the rotation of the Tuohy introducer needle 45 degrees toward the operative side before threading the epidural catheter provides a preferential distribution of sensory and motor block toward the operative side, reducing the volume of local anesthetic solution required to maintain postoperative analgesia. Turning the Tuohy introducer needle 45 degrees toward the operative side before threading the epidural catheter is a simple maneuver that produces a preferential distribution of epidural anesthesia and analgesia toward the operative side, minimizing the volume of local anesthetic required to provide adequate pain relief after total hip arthroplasty.
Can using a peel-away sheath in shunt implantation prevent ventricular catheter obstruction?
Camlar, Mahmut; Ersahin, Yusuf; Ozer, Fusun Demirçivi; Sen, Fatih; Orman, Mehmet
2011-02-01
Shunt obstruction is the most common shunt complication. In 2003, Kehler et al. used peel-away sheath while implanting the ventricular catheter in 20 patients. They found less revision rate in the peel-away sheath group. We aimed to test the efficacy of this technique in cadavers. We used 100 fresh brains obtained from medicolegal autopsies. Posterior parietal and frontal approaches were used to puncture the lateral ventricle in each cerebral hemisphere. The ventricle is punctured with a peel-away sheath system. After the ventricle is reached, the mandarin is retracted and the ventricular catheter is introduced through the opening. The ventricular catheter was removed from the ventricle, the opening at the tip of the ventricular catheter was checked out for obstruction, and the number of patent and plugged openings was recorded. This procedure was repeated four times for each location with and without using peel-away sheath. The control group consisted of the procedures done without using peel-away sheath. The number of the plugged openings in the peel-away sheath group was significantly smaller than the control group. There was no significant difference between the two groups in terms of gender and left and right cerebral hemispheres. The obstruction rate was significantly lower in the posterior parietal approach. Pearson's correlation showed that increasing age was associated with less obstruction rate. Peel-away sheath decreases the number of plugged openings of the ventricular catheter. A clinical cooperative study is needed to prove that a peel-away sheath should be included in the ventricular shunt systems in the market.
An efficient cardiac mapping strategy for radiofrequency catheter ablation with active learning.
Feng, Yingjing; Guo, Ziyan; Dong, Ziyang; Zhou, Xiao-Yun; Kwok, Ka-Wai; Ernst, Sabine; Lee, Su-Lin
2017-07-01
A major challenge in radiofrequency catheter ablation procedures is the voltage and activation mapping of the endocardium, given a limited mapping time. By learning from expert interventional electrophysiologists (operators), while also making use of an active-learning framework, guidance on performing cardiac voltage mapping can be provided to novice operators or even directly to catheter robots. A learning from demonstration (LfD) framework, based upon previous cardiac mapping procedures performed by an expert operator, in conjunction with Gaussian process (GP) model-based active learning, was developed to efficiently perform voltage mapping over right ventricles (RV). The GP model was used to output the next best mapping point, while getting updated towards the underlying voltage data pattern as more mapping points are taken. A regularized particle filter was used to keep track of the kernel hyperparameter used by GP. The travel cost of the catheter tip was incorporated to produce time-efficient mapping sequences. The proposed strategy was validated on a simulated 2D grid mapping task, with leave-one-out experiments on 25 retrospective datasets, in an RV phantom using the Stereotaxis Niobe ® remote magnetic navigation system, and on a tele-operated catheter robot. In comparison with an existing geometry-based method, regression error was reduced and was minimized at a faster rate over retrospective procedure data. A new method of catheter mapping guidance has been proposed based on LfD and active learning. The proposed method provides real-time guidance for the procedure, as well as a live evaluation of mapping sufficiency.
Schwein, Adeline; Kramer, Benjamin; Chinnadurai, Ponraj; Virmani, Neha; Walker, Sean; O'Malley, Marcia; Lumsden, Alan B; Bismuth, Jean
2018-04-01
Combining three-dimensional (3D) catheter control with electromagnetic (EM) tracking-based navigation significantly reduced fluoroscopy time and improved robotic catheter movement quality in a previous in vitro pilot study. The aim of this study was to expound on previous results and to expand the value of EM tracking with a novel feature, assistednavigation, allowing automatic catheter orientation and semiautomatic vessel cannulation. Eighteen users navigated a robotic catheter in an aortic aneurysm phantom using an EM guidewire and a modified 9F robotic catheter with EM sensors at the tip of both leader and sheath. All users cannulated two targets, the left renal artery and posterior gate, using four visualization modes: (1) Standard fluoroscopy (control). (2) 2D biplane fluoroscopy showing real-time virtual catheter localization and orientation from EM tracking. (3) 2D biplane fluoroscopy with novel EM assisted navigation allowing the user to define the target vessel. The robotic catheter orients itself automatically toward the target; the user then only needs to advance the guidewire following this predefined optimized path to catheterize the vessel. Then, while advancing the catheter over the wire, the assisted navigation automatically modifies catheter bending and rotation in order to ensure smooth progression, avoiding loss of wire access. (4) Virtual 3D representation of the phantom showing real-time virtual catheter localization and orientation. Standard fluoroscopy was always available; cannulation and fluoroscopy times were noted for every mode and target cannulation. Quality of catheter movement was assessed by measuring the number of submovements of the catheter using the 3D coordinates of the EM sensors. A t-test was used to compare the standard fluoroscopy mode against EM tracking modes. EM tracking significantly reduced the mean fluoroscopy time (P < .001) and the number of submovements (P < .02) for both cannulation tasks. For the posterior gate, mean cannulation time was also significantly reduced when using EM tracking (P < .001). The use of novel EM assisted navigation feature (mode 3) showed further reduced cannulation time for the posterior gate (P = .002) and improved quality of catheter movement for the left renal artery cannulation (P = .021). These results confirmed the findings of a prior study that highlighted the value of combining 3D robotic catheter control and 3D navigation to improve safety and efficiency of endovascular procedures. The novel EM assisted navigation feature augments the robotic master/slave concept with automated catheter orientation toward the target and shows promising results in reducing procedure time and improving catheter motion quality. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Transbronchial needle aspiration with a new electromagnetically-tracked TBNA needle
NASA Astrophysics Data System (ADS)
Choi, Jae; Popa, Teo; Gruionu, Lucian
2009-02-01
Transbronchial needle aspiration (TBNA) is a common method used to collect tissue for diagnosis of different chest diseases and for staging lung cancer, but the procedure has technical limitations. These limitations are mostly related to the difficulty of accurately placing the biopsy needles into the target mass. Currently, pulmonologists plan TBNA by examining a number of Computed Tomography (CT) scan slices before the operation. Then, they manipulate the bronchoscope down the respiratory track and blindly direct the biopsy. Thus, the biopsy success rate is low. The diagnostic yield of TBNA is approximately 70 percent. To enhance the accuracy of TBNA, we developed a TBNA needle with a tip position that can be electromagnetically tracked. The needle was used to estimate the bronchoscope's tip position and enable the creation of corresponding virtual bronchoscopic images from a preoperative CT scan. The TBNA needle was made with a flexible catheter embedding Wang Transbronchial Histology Needle and a sensor tracked by electromagnetic field generator. We used Aurora system for electromagnetic tracking. We also constructed an image-guided research prototype system incorporating the needle and providing a user-friendly interface to assist the pulmonologist in targeting lesions. To test the feasibility of the accuracy of the newly developed electromagnetically-tracked needle, a phantom study was conducted in the interventional suite at Georgetown University Hospital. Five TBNA simulations with a custom-made phantom with a bronchial tree were performed. The experimental results show that our device has potential to enhance the accuracy of TBNA.
Miyayama, Shiro; Yamashiro, Masashi; Hattori, Yuki; Orito, Nobuaki; Matsui, Ken; Tsuji, Kazunobu; Yoshida, Miki; Matsui, Osamu
2011-05-01
The aim of this study was to evaluate the technical aspects of embolization using microcoils through a microcatheter with a tip of 2F or smaller during abdominal vascular interventions. Coil embolization through a microcatheter with a tip of 2F or smaller was attempted in 73 procedures. Two types of microcoil-Liquid Coil (Boston Scientific, Watertown, MA, USA) and Tornado Coil (Cook, Bloomington, IN, USA)-were deployed through four types of thinner microcatheter [2F tip (n = 49) and 1.8F tip (n = 24)]. Coil jams in the microcatheter and coil migration were evaluated. In total, 286 microcoils were placed (mean ± SD, 3.9 ± 4.3 coils per procedure, range 1-32 coils). In 19 procedures (26.9%), Liquid Coils were used alone. In 44 (60.3%), Tornado Coils were used alone. In 10 (13.7%), Liquid Coils and Tornado Coils were combined. There were no coil jams in the microcatheter in this series. One Tornado Coil (0.3%) delivered into the gastroduodenal artery migrated to the right hepatic artery. Liquid Coils and Tornado Coils can be placed through a thinner microcatheter without difficulty. However, there is a risk of coil migration in large vessels or at the proximal site because the catheter tip is not stabilized.
Di Biase, Luigi; Santangeli, Pasquale; Astudillo, Vladimir; Conti, Sergio; Mohanty, Prasant; Mohanty, Sanghamitra; Sanchez, Javier E; Horton, Rodney; Thomas, Barbara; Burkhardt, J David; Natale, Andrea
2010-08-01
Remote magnetic navigation (RMN) has been reported as a feasible and safe mapping and ablation system for treatment of ventricular arrhythmias (VAs). However, the reported success rates have been limited with the 4- and 8-mm catheter tips. This study sought to report the results in a large series of consecutive patients undergoing radiofrequency (RF) catheter ablation of VAs using the RMN with the 3.5-mm magnetic open-irrigated-tip catheter (OIC). A total of 110 consecutive patients with a clinical history of left VA were included in the study. In all cases, an OIC was utilized for mapping and ablation. When ablation with the RMN catheters failed, a manual OIC was used to eliminate the VA. Postablation pacing maneuvers and isoproterenol were used to verify the inducibility of the VAs. Outcomes were compared with those of a group of 92 consecutive patients undergoing manual ablation by the same operator. Mapping and ablation with the magnetic OIC were performed in all 110 patients with VA. Ischemic cardiomyopathy was present in 33 (30%), nonischemic in 14 (13%), and in 63 (57%) patients no structural heart disease was present. Endocardial mapping was performed in all patients, whereas both endocardial and epicardial mapping were performed in 36 (33%) patients. Compared with manual ablation, RMN was associated with a longer procedural time (2.9 +/- 1.2 hours vs. 3.3 +/- 1.1 hours, P = 0.004) and RF time (24 +/- 12 minutes vs. 33 +/- 18 minutes, P = 0.005), whereas fluoroscopic time was significantly shorter (35 +/- 22 minutes vs. 26 +/- 14 minutes, P = 0.033). During the procedures, crossover to manual ablation was required in 15 patients (14%). At 11.7 +/- 2.1 months of follow-up in the study group and 18.7 +/- 3.7 months in the manual ablation group, 85% and 86% (P = 0.817) of patients, respectively, were free of VA. This large series of consecutive patients demonstrates that OIC ablation using RMN is effective for the treatment of left VAs. Copyright 2010 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Moftakhar, Parham; Lillaney, Prasheel; Losey, Aaron D; Cooke, Daniel L; Martin, Alastair J; Thorne, Bradford R H; Arenson, Ronald L; Saeed, Maythem; Wilson, Mark W; Hetts, Steven W
2015-12-01
To assess the feasibility of multiplanar vascular navigation with a new magnetically assisted remote-controlled (MARC) catheter with real-time magnetic resonance (MR) imaging at 1.5 T and 3 T and to compare it with standard x-ray guidance in simulated endovascular catheterization procedures. A 1.6-mm-diameter custom clinical-grade microcatheter prototype with lithographed double-saddle coils at the distal tip was deflected with real-time MR imaging. Two inexperienced operators and two experienced operators catheterized anteroposterior (celiac, superior mesenteric, and inferior mesenteric arteries) and mediolateral (renal arteries) branch vessels in a cryogel abdominal aortic phantom. This was repeated with conventional x-ray fluoroscopy by using clinical catheters and guidewires. Mean procedure times and percentage success data were analyzed with linear mixed-effects regression. The MARC catheter tip was visible at 1.5 T and 3 T. Among inexperienced operators, MARC MR imaging guidance was not statistically different from x-ray guidance at 1.5 T (67% successful vessel selection turns with MR imaging vs 76% with x-ray guidance, P = .157) and at 3 T (75% successful turns with MR imaging vs 76% with x-ray guidance, P = .869). Experienced operators were more successful in catheterizing vessels with x-ray guidance (98% success within 60 seconds) than with 1.5-T (65%, P < .001) or 3-T (75%) MR imaging. Among inexperienced operators, mean procedure time was nearly equivalent by using MR imaging (31 seconds) and x-ray guidance (34 seconds, P = .436). Among experienced operators, catheterization was faster with x-ray guidance (20 seconds) compared with 1.5-T MR imaging (42 seconds, P < .001), but MARC guidance improved at 3 T (31 seconds). MARC MR imaging guidance at 3 T was not significantly different from x-ray guidance for the celiac (P = .755), superior mesenteric (P = .358), and inferior mesenteric (P = .065) arteries. Multiplanar navigation with a new MARC catheter with real-time MR imaging at 1.5 T and 3 T is feasible and comparable to x-ray guidance for anteroposterior vessels at 3 T in a vascular phantom.
Moftakhar, Parham; Lillaney, Prasheel; Losey, Aaron D.; Cooke, Daniel L.; Martin, Alastair J.; Thorne, Bradford R. H.; Arenson, Ronald L.; Saeed, Maythem; Wilson, Mark W.
2015-01-01
Purpose To assess the feasibility of multiplanar vascular navigation with a new magnetically assisted remote-controlled (MARC) catheter with real-time magnetic resonance (MR) imaging at 1.5 T and 3 T and to compare it with standard x-ray guidance in simulated endovascular catheterization procedures. Materials and Methods A 1.6-mm–diameter custom clinical-grade microcatheter prototype with lithographed double-saddle coils at the distal tip was deflected with real-time MR imaging. Two inexperienced operators and two experienced operators catheterized anteroposterior (celiac, superior mesenteric, and inferior mesenteric arteries) and mediolateral (renal arteries) branch vessels in a cryogel abdominal aortic phantom. This was repeated with conventional x-ray fluoroscopy by using clinical catheters and guidewires. Mean procedure times and percentage success data were analyzed with linear mixed-effects regression. Results The MARC catheter tip was visible at 1.5 T and 3 T. Among inexperienced operators, MARC MR imaging guidance was not statistically different from x-ray guidance at 1.5 T (67% successful vessel selection turns with MR imaging vs 76% with x-ray guidance, P = .157) and at 3 T (75% successful turns with MR imaging vs 76% with x-ray guidance, P = .869). Experienced operators were more successful in catheterizing vessels with x-ray guidance (98% success within 60 seconds) than with 1.5-T (65%, P < .001) or 3-T (75%) MR imaging. Among inexperienced operators, mean procedure time was nearly equivalent by using MR imaging (31 seconds) and x-ray guidance (34 seconds, P = .436). Among experienced operators, catheterization was faster with x-ray guidance (20 seconds) compared with 1.5-T MR imaging (42 seconds, P < .001), but MARC guidance improved at 3 T (31 seconds). MARC MR imaging guidance at 3 T was not significantly different from x-ray guidance for the celiac (P = .755), superior mesenteric (P = .358), and inferior mesenteric (P = .065) arteries. Conclusion Multiplanar navigation with a new MARC catheter with real-time MR imaging at 1.5 T and 3 T is feasible and comparable to x-ray guidance for anteroposterior vessels at 3 T in a vascular phantom. © RSNA, 2015 Online supplemental material is available for this article. PMID:26030659
Feedforward Coordinate Control of a Robotic Cell Injection Catheter.
Cheng, Weyland; Law, Peter K
2017-08-01
Remote and robotically actuated catheters are the stepping-stones toward autonomous catheters, where complex intravascular procedures may be performed with minimal intervention from a physician. This article proposes a concept for the positional, feedforward control of a robotically actuated cell injection catheter used for the injection of myogenic or undifferentiated stem cells into the myocardial infarct boundary zones of the left ventricle. The prototype for the catheter system was built upon a needle-based catheter with a single degree of deflection, a 3-D printed handle combined with actuators, and the Arduino microcontroller platform. A bench setup was used to mimic a left ventricle catheter procedure starting from the femoral artery. Using Matlab and the open-source video modeling tool Tracker, the planar coordinates ( y, z) of the catheter position were analyzed, and a feedforward control system was developed based on empirical models. Using the Student's t test with a sample size of 26, it was determined that for both the y- and z-axes, the mean discrepancy between the calibrated and theoretical coordinate values had no significant difference compared to the hypothetical value of µ = 0. The root mean square error of the calibrated coordinates also showed an 88% improvement in the z-axis and 31% improvement in the y-axis compared to the unmodified trial run. This proof of concept investigation leads to the possibility of further developing a feedfoward control system in vivo using catheters with omnidirectional deflection. Feedforward positional control allows for more flexibility in the design of an automated catheter system where problems such as systemic time delay may be a hindrance in instances requiring an immediate reaction.
Positioning of nasobiliary tube using magnet-loaded catheters.
Watanabe, Seitaro; Sato, Takamitsu; Kato, Shingo; Hosono, Kunihiro; Kobayashi, Noritoshi; Nakajima, Atsushi; Kubota, Kensuke
2013-10-01
In endoscopic nasobiliary drainage (ENBD), repositioning the catheter from the mouth to the nose is complicated. We devised a method using catheters with magnets and verified its utility and safety. We prospectively enrolled 20 patients undergoing ENBD at Yokohama City University Hospital. The procedures were successful in all 20 cases and no case required a change of operators to a senior doctor. The mean time for the procedure was 36.6 seconds. The emetic reflex was induced 0.5 times on average using the magnet method. The mean X-ray exposure time was 29.6 seconds. No complications occurred. The magnet-loaded catheter method for positioning the ENBD catheter before finally leading it through the nose took little time and was performed successfully and safely. Therefore, the magnet method could become the first choice among techniques for ENBD catheter placement. © Georg Thieme Verlag KG Stuttgart · New York.
On the use of particle filters for electromagnetic tracking in high dose rate brachytherapy.
Götz, Th I; Lahmer, G; Brandt, T; Kallis, K; Strnad, V; Bert, Ch; Hensel, B; Tomé, A M; Lang, E W
2017-09-12
Modern radiotherapy of female breast cancers often employs high dose rate brachytherapy, where a radioactive source is moved inside catheters, implanted in the female breast, according to a prescribed treatment plan. Source localization relative to the patient's anatomy is determined with solenoid sensors whose spatial positions are measured with an electromagnetic tracking system. Precise sensor dwell position determination is of utmost importance to assure irradiation of the cancerous tissue according to the treatment plan. We present a hybrid data analysis system which combines multi-dimensional scaling with particle filters to precisely determine sensor dwell positions in the catheters during subsequent radiation treatment sessions. Both techniques are complemented with empirical mode decomposition for the removal of superimposed breathing artifacts. We show that the hybrid model robustly and reliably determines the spatial positions of all catheters used during the treatment and precisely determines any deviations of actual sensor dwell positions from the treatment plan. The hybrid system only relies on sensor positions measured with an EMT system and relates them to the spatial positions of the implanted catheters as initially determined with a computed x-ray tomography.
Bansal, Anu; Binkert, Christoph A; Robinson, Malcolm K; Shulman, Lawrence N; Pellerin, Linda; Davison, Brian
2008-08-01
To assess the utility of maintaining and analyzing a quality-management database while investigating a subjectively perceived increase in the incidence of tunneled catheter and port dysfunction in a cohort of oncology outpatients. All 152 patients undergoing lytic therapy (2-4 mg alteplase) of a malfunctioning indwelling central venous catheter (CVC) from January through June 2004 at a single cancer center in the United States were included in a quality-management database. Patients were categorized by time to device failure and the initial method of catheter placement (surgery vs interventional radiology). Data were analyzed after 3 months, and areas of possible improvement were identified and acted upon. Three months of follow-up data were then collected and similarly analyzed. In a 6-month period, 152 patients treated for catheter malfunction received a total of 276 doses of lytic therapy. A 3-month interim analysis revealed a disproportionately high rate (34%) of early catheter malfunction (ECM; <30 days from placement). Postplacement radiographs demonstrated suboptimal catheter positioning in 67% of these patients, all of whom had surgical catheter placement. There was a 50% absolute decrease in the number of patients presenting with catheter malfunction in the period from April through June (P < .001). Evaluation of postplacement radiographs in these patients demonstrated a 50% decrease in the incidence of suboptimal positioning (P < .05). Suboptimal positioning was likely responsible for some, but not all, cases of ECM. Maintenance of a quality-management database is a relatively simple intervention that can have a clear and important impact on the quality and cost of patient care.
Borgeat, A; Ekatodramis, G; Guzzella, S; Ruland, P; Votta-Velis, G; Aguirre, J
2012-12-01
The influence of the muscular response elicited by neurostimulation on the success rate of interscalene block using a catheter (ISC) is unknown. In this investigation, we compared the success rate of ISC placement as indicated by biceps or deltoid, triceps, or both twitches. Three hundred (ASA I-II) patients presenting for elective arthroscopic rotator cuff repair were prospectively randomized to assessment by biceps (Group B) or deltoid, triceps, or both twitches (Group DT). All ISCs were placed with the aid of neurostimulation. The tip of the stimulating needle was placed after disappearance of either biceps or deltoid, triceps, or both twitches at 0.3 mA. The catheter was advanced 2-3 cm past the tip of the needle and the block was performed using 40 ml ropivacaine 0.5%. Successful block was defined as sensory block of the supraclavicular nerve and sensory and motor block involving the axillary, radial, median, and musculocutaneous nerves within 30 min. Success rate was 98.6% in Group DT compared with 92.5% in Group B (95% confidence interval 0.01-0.11; P<0.02). Supplemental analgesics during handling of the posterior part of the shoulder capsule were needed in two patients in Group DT and seven patients in Group B. Three patients in Group B had an incomplete radial nerve distribution anaesthesia necessitating general anaesthesia. One patient in Group B had an incomplete posterior block extension of the supraclavicular nerve. No acute or late complications were observed. Eliciting deltoid, triceps, or both twitches was associated with a higher success rate compared with eliciting biceps twitches during continuous interscalene block.
A fiberoptic reflection oximeter.
Landsman, M L; Knop, N; Kwant, G; Mook, G A; Zijlstra, W G
1978-03-20
A catheter tip oximeter is described consisting of a cardiac catheter containing optical fibers, and incandescent light source, a light detection unit and a processing unit. Half of the optical fibers guide the light to the blood at the tip of the catheter, the other half the backscattered (reflected) light to the detection unit. The detection unit contains a dichroic mirror, transmitting most of the light with lambda less than 800 nm and reflecting most of the light with lambda greater than 900 nm, thus splitting the light into two beams. These pass through interference filters with nominal wavelengths of 640 and 920 nm respectively, and are focused on silicium barrier layer photocells. The photocell signals are amplified and fed into a divider giving the ratio of measuring (R640) and compensating (R920) photocell output. The relationship between log R640/R920 and oxygen saturation is represented by a slightly curved line. The relation may be linearized by subtracting a constant voltage from the divided output before taking the logarithm. The slope of the calibration line is dependent on the total haemoglobin concentration. Nonetheless an average calibration line can be used between 70 and 100% oxygen saturation. For 78 measurements of pig blood samples in this range (haemoglobin concentration between 96 and 161 g.1(-1)), the standard deviation of the difference between the fiberoptic oximeter and a Radiometer OSM1 oxygen saturation meter was 1.9% saturation, for 152 samples over the entire saturation range the standard deviation of the difference was 3.1% saturation. The influence of the flow velocity of blood on the light reflection depends on wavelength as well as on oxygen saturation. Therefore, complete compensation for the flow effect is not possible by simple means.
Greer, Rebecca J; Cohn, Leah A; Dodam, John R; Wagner-Mann, Colette C; Mann, F A
2007-06-15
To assess the reliability and accuracy of a predictive rectal thermometer, an infrared auricular thermometer designed for veterinary use, and a subcutaneous temperature-sensing microchip for measurement of core body temperature over various temperature conditions in dogs. Prospective study. 8 purpose-bred dogs. A minimum of 7 days prior to study commencement, a subcutaneous temperature-sensing microchip was implanted in 1 of 3 locations (interscapular, lateral aspect of shoulder, or sacral region) in each dog. For comparison with temperatures measured via rectal thermometer, infrared auricular thermometer, and microchip, core body temperature was measured via a thermistor-tipped pulmonary artery (TTPA) catheter. Hypothermia was induced during anesthesia at the time of TTPA catheter placement; on 3 occasions after placement of the catheter, hyperthermia was induced via administration of a low dose of endotoxin. Near-simultaneous duplicate temperature measurements were recorded from the TTPA catheter, the rectal thermometer, auricular thermometer, and subcutaneous microchips during hypothermia, euthermia, and hyperthermia. Reliability (variability) of temperature measurement for each device and agreement between each device measurement and core body temperature were assessed. Variability between duplicate near-simultaneous temperature measurements was greatest for the auricular thermometer and least for the TTPA catheter. Measurements obtained by use of the rectal thermometer were in closest agreement with core body temperature; for all other devices, temperature readings typically underestimated core body temperature. Among the 3 methods of temperature measurement, rectal thermometry provided the most accurate estimation of core body temperature in dogs.
Successful retrieval of an entrapped Rotablator burr using 5 Fr guiding catheter.
Kimura, Masayoshi; Shiraishi, Jun; Kohno, Yoshio
2011-10-01
Although burr entrapment is a rare complication of the Rotablator, it is extremely difficult to retrieve a fixedly entrapped burr without surgical procedure. An 84-year-old male with effort angina had heavily calcified coronary trees as well as severe stenosis in the mid LCx, and moderate stenosis in the proximal LCx, and in the LMT. We planned to perform rotational atherectomy in the LCx lesions. Using 7 Fr Q-curve guiding catheter and Rotawire floppy, we began to ablate using 1.5-mm burr at 200,000 rpm. Because the burr could not pass the proximal stenosis, we exchanged the wire for Rotawire extrasupport and the burr for 1.25-mm burr, and restarted the ablation at 220,000 rpm. Although the burr could manage to pass the proximal stenosis, it had become trapped in the mid LCx lesion. Simple pull on the Rotablator, rotation of the burr, and crossing the Conquest (Confianza) wire could not retrieve it. Thus, we cut off the drive shaft and sheath of the Rotablator, inserted 5 Fr 120-cm straight guiding catheter (Heartrail ST01; Terumo) through the remaining Rotablator system, pushed the catheter tip to the lesion around the burr as well as simultaneously pulled the Rotablator, and finally could retrieve it. Then we implanted stents in the LCx and in the LMT without difficulty. The 5 Fr straight guiding catheter might be useful for retrieving an entrapped burr (1.25-mm burr). Copyright © 2011 Wiley-Liss, Inc.
Performance evaluation of a robot-assisted catheter operating system with haptic feedback.
Song, Yu; Guo, Shuxiang; Yin, Xuanchun; Zhang, Linshuai; Hirata, Hideyuki; Ishihara, Hidenori; Tamiya, Takashi
2018-06-20
In this paper, a novel robot-assisted catheter operating system (RCOS) has been proposed as a method to reduce physical stress and X-ray exposure time to physicians during endovascular procedures. The unique design of this system allows the physician to apply conventional bedside catheterization skills (advance, retreat and rotate) to an input catheter, which is placed at the master side to control another patient catheter placed at the slave side. For this purpose, a magnetorheological (MR) fluids-based master haptic interface has been developed to measure the axial and radial motions of an input catheter, as well as to provide the haptic feedback to the physician during the operation. In order to achieve a quick response of the haptic force in the master haptic interface, a hall sensor-based closed-loop control strategy is employed. In slave side, a catheter manipulator is presented to deliver the patient catheter, according to position commands received from the master haptic interface. The contact forces between the patient catheter and blood vessel system can be measured by designed force sensor unit of catheter manipulator. Four levels of haptic force are provided to make the operator aware of the resistance encountered by the patient catheter during the insertion procedure. The catheter manipulator was evaluated for precision positioning. The time lag from the sensed motion to replicated motion is tested. To verify the efficacy of the proposed haptic feedback method, the evaluation experiments in vitro are carried out. The results demonstrate that the proposed system has the ability to enable decreasing the contact forces between the catheter and vasculature.
Goltz, J P; Noack, C; Petritsch, B; Kirchner, J; Hahn, D; Kickuth, R
2012-01-01
Objectives To evaluate the technical success, clinical outcome and safety of percutaneously placed totally implantable venous power ports (TIVPPs) approved for high-pressure injections, and to analyse their value for arterial phase CT scans. Methods Retrospectively, we identified 204 patients who underwent TIVPP implantation in the forearm (n=152) or chest (n=52) between November 2009 and May 2011. Implantation via an upper arm (forearm port, FP) or subclavian vein (chest port, CP) was performed under sonographic and fluoroscopic guidance. Complications were evaluated following the standards of the Society of Interventional Radiology. Power injections via TIVPPs were analysed, focusing on adequate functioning and catheter's tip location after injection. Feasibility of automatic bolus triggering, peak injection pressure and arterial phase aortic enhancement were evaluated and compared with 50 patients who had had power injections via classic peripheral cannulas. Results Technical success was 100%. Procedure-related complications were not observed. Catheter-related thrombosis was diagnosed in 15 of 152 FPs (9.9%, 0.02/100 catheter days) and in 1 of 52 CPs (1.9%, 0.002/100 catheter days) (p<0.05). Infectious complications were diagnosed in 9 of 152 FPs (5.9%, 0.014/100 catheter days) and in 2 of 52 CPs (3.8%, 0.003/100 catheter days) (p>0.05). Arterial bolus triggering succeeded in all attempts; the mean injection pressure was 213.8 psi. Aortic enhancement did not significantly differ between injections via cannulas and TIVPPs (p>0.05). Conclusions TIVPPs can be implanted with high technical success rates, and are associated with low rates of complications if implanted with sonographic and fluoroscopic guidance. Power injections via TIVPPs are safe and result in satisfying arterial contrast. Conventional ports should be replaced by TIVPPs. PMID:22674705
Rozen, Guy; Ptaszek, Leon; Zilberman, Israel; Cordaro, Kevin; Heist, E Kevin; Beeckler, Christopher; Altmann, Andres; Ying, Zhang; Liu, Zhenjiang; Ruskin, Jeremy N; Govari, Assaf; Mansour, Moussa
2017-02-01
Real-time radiofrequency (RF) ablation lesion assessment is a major unmet need in cardiac electrophysiology. The purpose of this study was to assess whether improved temperature measurement using a novel thermocoupling (TC) technology combined with information derived from impedance change, contact force (CF) sensing, and catheter orientation allows accurate real-time prediction of ablation lesion formation. RF ablation lesions were delivered in the ventricles of 15 swine using a novel externally irrigated-tip catheter containing 6 miniature TC sensors in addition to force sensing technology. Ablation duration, power, irrigation rate, impedance drop, CF, and temperature from each sensor were recorded. The catheter "orientation factor" was calculated using measurements from the different TC sensors. Information derived from all the sources was included in a mathematical model developed to predict lesion depth and validated against histologic measurements. A total of 143 ablation lesions were delivered to the left ventricle (n = 74) and right ventricle (n = 69). Mean CF applied during the ablations was 14.34 ± 3.55g, and mean impedance drop achieved during the ablations was 17.5 ± 6.41 Ω. Mean difference between predicted and measured ablation lesion depth was 0.72 ± 0.56 mm. In the majority of lesions (91.6%), the difference between estimated and measured depth was ≤1.5 mm. Accurate real-time prediction of RF lesion depth is feasible using a novel ablation catheter-based system in conjunction with a mathematical prediction model, combining elaborate temperature measurements with information derived from catheter orientation, CF sensing, impedance change, and additional ablation parameters. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Kosmidou, Ioanna; Houde-Walter, Haley; Foley, Lori; Michaud, Gregory
2013-04-01
Lesion transmurality is critical to procedural success in radiofrequency catheter ablation. We sought to determine whether loss of pace capture (PC) with high-output unipolar and/or bipolar pacing predicts the formation of uniform transmural lesions. Ten juvenile swine were anaesthetized and prepped under sterile conditions. Seventy-seven isolated radiofrequency applications (RFAs) using a 3.5 mm tip-irrigated catheter were available for analysis. Pace capture was assessed before and after RFA at 10 mA/2 ms and catheter stability verified with a three-dimensional mapping system. Pace capture was defined as 1 : 1 or intermittent local capture per paced beat. Myocardial contact and catheter orientation were assessed using intracardiac echo. Endocardial and epicardial lesion areas were measured after sacrifice using 2,3,5-triphenyltetrazolium chloride staining. A uniform transmural lesion was defined as an epicardial-to-endocardial surface ratio (epi/endo) ≥ 76%. Seventy-four per cent of lesions were transmural and 55.8% of lesions had an epi/endo ratio ≥ 76%. In all, 79.2% of lesions associated with loss of bipolar PC were uniform whereas 20.8% of lesions with loss of bipolar PC were non-uniform (P = 0.006). Loss of bipolar PC was associated with higher mean epicardial/endocardial ratio compared with lesions with persistent PC (P = 0.019). Echocardiographic evidence of optimal catheter contact during RFA improved the predictive accuracy of uniform lesion formation when loss of bipolar PC was noted after RFA. Loss of bipolar PC after RFA is associated with the formation of uniform lesions in atrial tissue. Optimal catheter contact further improves the predictive accuracy associated with loss of PC.
Intracranial placement of a new, compliant guide catheter: technical note.
Park, Min S; Stiefel, Michael F; Fiorella, David; Kelly, Michael; McDougall, Cameron G; Albuquerque, Felipe C
2008-09-01
We describe our initial experience with the use of a novel, compliant guide catheter designed for placement within the cranial vasculature in a series of seven patients who were treated for various intracranial pathologies. Seven patients were deemed to have either tortuous supra-aortic, intracranial, and/or extracranial vasculature or to require additional microcatheter support as the result of lesion location. The patients were treated, in part, with the 6-French Neuron delivery catheter (Penumbra, Inc., San Leandro, CA) at the authors' two institutions. The guide catheter was positioned in various distal locations within the intracranial internal carotid artery or external carotid artery. Three patients were treated for unruptured intracranial aneurysms, 2 patients for intracranial atherosclerosis, 1 patient for an arteriovenous malformation, and 1 patient for a pseudoaneurysm. All lesions were successfully treated through a microcatheter advanced in a coaxial fashion through the guide catheter. There were no complications related to the positioning of the catheter. Distal intra- or extracranial placement of a specially designed, compliant guide catheter can be performed safely and may improve access and microcatheter stability in patients with tortuous vessels or difficult-to-reach lesions.
Harris, Benjamin D; Nilsson, Sanna; Poole, Christopher M
2015-09-01
This feasibility study aims to determine if a low-cost 3D printer (BitsFromBytes 3D Touch) with ABS plastic can print custom mould structures and catheter channels defined in a brachytherapy treatment planning system (Nucletron Oncentra) for patient-specific treatment. Printer accuracy was evaluated through physical measurement, and print quality was investigated by adjusting print parameters (print speed, layer thickness, percentage infill). Catheter positioning and reproducibility were measured over repeated insertions. ABS plastic water equivalency was investigated by comparing Ir-192 HDR source dose distributions, measured with radiochromic film, in ABS plastic and in water. Structures and catheter channels were printed accurately to within 0.5 mm laterally and 1 mm in the vertical print direction. Adjusting print parameters could reduce print time, albeit with reduced print quality. 3.5 mm channel diameters allowed for easy catheter insertion. Catheter positioning was reproducible to within 0.5 mm but, because of catheter flex within the channel, was on average 1 mm offset from defined TPS positions. This offset could be accounted for by repeating the treatment planning CT scan with the printed mould positioned on the patient. Dose attenuation in ABS plastic and in water was equivalent to within the measurement limitations. While clinical uses for this particular low-cost printer and ABS plastic are limited by print size restrictions and non-certification for biocompatibility, it has been demonstrated that a low-cost 3D printer set-up can accurately create custom moulds and catheter channels potentially acceptable for clinical use.
A study of pre-antibiotic bacteriology in 125 patients with necrotizing enterocolitis.
Chan, K L; Saing, H; Yung, R W; Yeung, Y P; Tsoi, N S
1994-01-01
Over a five-year period, 125 newborns with necrotizing enterocolitis (NEC) were managed by us. Their mean birthweight was 1700 g and mean maturity was 32 weeks. Before commencement of antibiotics, routine septic work-up was done in order to define the bacterial spectrum and antibiotic sensitivity. The study includes aerobic and anaerobic cultures of gastric and pharyngeal aspirates, blood cultures, umbilical swabs and culture of umbilical catheter tips in relevant cases. Peritoneal swab results were also analyzed if laparatomy was performed. Positive cultures were present in 45 patients (36%) with 55 positive specimens. Fifteen types of organism were isolated: the commonest was Enterobacter (29%), followed by E. coli (14.5%) and Klebsiella (13%). They were resistant to ampicillin and first-generation cephalosporin. These organisms were usually opportunistic pathogens. Overgrowth of them may be the cause of NEC. Regular review of the antibiotic sensitivity of these organisms allows prompt and appropriate choice of antibiotics. At the same time, antibiotic sensitivity for these organisms was analyzed to guide us in the choice of antibiotic therapy.
On the use of particle filters for electromagnetic tracking in high dose rate brachytherapy
NASA Astrophysics Data System (ADS)
Götz, Th I.; Lahmer, G.; Brandt, T.; Kallis, K.; Strnad, V.; Bert, Ch; Hensel, B.; Tomé, A. M.; Lang, E. W.
2017-10-01
Modern radiotherapy of female breast cancers often employs high dose rate brachytherapy, where a radioactive source is moved inside catheters, implanted in the female breast, according to a prescribed treatment plan. Source localization relative to the patient’s anatomy is determined with solenoid sensors whose spatial positions are measured with an electromagnetic tracking system. Precise sensor dwell position determination is of utmost importance to assure irradiation of the cancerous tissue according to the treatment plan. We present a hybrid data analysis system which combines multi-dimensional scaling with particle filters to precisely determine sensor dwell positions in the catheters during subsequent radiation treatment sessions. Both techniques are complemented with empirical mode decomposition for the removal of superimposed breathing artifacts. We show that the hybrid model robustly and reliably determines the spatial positions of all catheters used during the treatment and precisely determines any deviations of actual sensor dwell positions from the treatment plan. The hybrid system only relies on sensor positions measured with an EMT system and relates them to the spatial positions of the implanted catheters as initially determined with a computed x-ray tomography.
Nikoozadeh, Amin; Wygant, Ira O.; Lin, Der-Song; Oralkan, Ömer; Ergun, A. Sanlı; Stephens, Douglas N.; Thomenius, Kai E.; Dentinger, Aaron M.; Wildes, Douglas; Akopyan, Gina; Shivkumar, Kalyanam; Mahajan, Aman; Sahn, David J.; Khuri-Yakub, Butrus T.
2009-01-01
Minimally invasive catheter-based electrophysiological (EP) interventions are becoming a standard procedure in diagnosis and treatment of cardiac arrhythmias. As a result of technological advances that enable small feature sizes and a high level of integration, nonfluoroscopic intracardiac echocardiography (ICE) imaging catheters are attracting increasing attention. ICE catheters improve EP procedural guidance while reducing the undesirable use of fluoroscopy, which is currently the common catheter guidance method. Phased-array ICE catheters have been in use for several years now, although only for side-looking imaging. We are developing a forward-looking ICE catheter for improved visualization. In this effort, we fabricate a 24-element, fine-pitch 1-D array of capacitive micromachined ultrasonic transducers (CMUT), with a total footprint of 1.73 mm × 1.27 mm. We also design a custom integrated circuit (IC) composed of 24 identical blocks of transmit/receive circuitry, measuring 2.1 mm × 2.1 mm. The transmit circuitry is capable of delivering 25-V unipolar pulses, and the receive circuitry includes a transimpedance preamplifier followed by an output buffer. The CMUT array and the custom IC are designed to be mounted at the tip of a 10-Fr catheter for high-frame-rate forward-looking intracardiac imaging. Through-wafer vias incorporated in the CMUT array provide access to individual array elements from the back side of the array. We successfully flip-chip bond a CMUT array to the custom IC with 100% yield. We coat the device with a layer of polydimethylsiloxane (PDMS) to electrically isolate the device for imaging in water and tissue. The pulse-echo in water from a total plane reflector has a center frequency of 9.2 MHz with a 96% fractional bandwidth. Finally, we demonstrate the imaging capability of the integrated device on commercial phantoms and on a beating ex vivo rabbit heart (Langendorff model) using a commercial ultrasound imaging system. PMID:19126489
Hollow mandrin facilitates external ventricular drainage placement.
Heese, O; Regelsberger, J; Kehler, U; Westphal, M
2005-07-01
Placement of ventricular catheters is a routine procedure in neurosurgery. Ventricle puncture is done using a flexible ventricular catheter stabilised by a solid steel mandrin in order to improve stability during brain penetration. A correct catheter placement is confirmed after removing the solid steel mandrin by observation of cerebrospinal fluid (CSF) flow out of the flexible catheter. Incorrect placement makes further punctures necessary. The newly developed device allows CSF flow observation during the puncture procedure and in addition precise intracranial pressure (ICP) measurement. The developed mandrin is hollow with a blunt tip. On one side 4-5 small holes with a diameter of 0.8 mm are drilled corresponding exactly with the holes in the ventricular catheter, allowing CSF to pass into the hollow mandrin as soon as the ventricle is reached. By connecting a small translucent tube at the distal portion of the hollow mandrin ICP can be measured without loss of CSF. The system has been used in 15 patients with subarachnoid haemorrhage (SAH) or intraventricular haemeorrhage (IVH) and subsequent hydrocephalus. The new system improved the external ventricular drainage implantation procedure. In all 15 patients catheter placement was correct. ICP measurement was easy to perform immediately at ventricle puncture. In 4 patients at puncture no spontaneous CSF flow was observed, therefore by connecting a syringe and gentle aspiration of CSF correct placement was confirmed in this unexpected low pressure hydrocephalus. Otherwise by using the conventional technique further punctures would have been necessary. Advantages of the new technique are less puncture procedures with a lower risk of damage to neural structures and reduced risk of intracranial haemorrhages. Implantation of the ventricular catheter to far into the brain can be monitored and this complication can be overcome. Using the connected pressure monitoring tube an exact measurement of the opening intracranial pressure can be obtained performed without losing CSF.
Wilde, Mary H.; Crean, Hugh F.; McMahon, James M.; McDonald, Margaret V.; Tang, Wan; Brasch, Judith; Fairbanks, Eileen; Shah, Shivani; Zhang, Feng
2015-01-01
Background Urinary tract infection and blockage are serious and recurrent challenges for people with long-term indwelling catheters, and these catheter problems cause worry and anxiety when they disrupt normal daily activities. Objectives The goal was to determine whether urinary catheter-related self-management behaviors focusing on fluid intake would mediate fluid intake related self-efficacy toward decreasing catheter-associated urinary tract infection (CAUTI) and/or catheter blockage. Method The sample involved data collected from 180 adult community-living, long-term indwelling urinary catheter users. The authors tested a model of fluid intake self-management (F-SMG) related to fluid intake self-efficacy (F-SE) for key outcomes of CAUTI and blockage. To account for the large number of zeros in both outcomes, a zero inflated negative binomial (ZINB) structural equation model was tested. Results Structurally, F-SE was positively associated with F-SMG, suggesting that higher F-SE predicts more (higher) F-SMG; however, F-SMG was not associated with either the frequency of CAUTI’s or the presence or absence of CAUTI. F-SE was positively related to F-SMG and F-SMG predicted less frequency of catheter blockage, but neither F-SE nor F-SMG predicted the presence or absence of blockage. Discussion Further research is needed to better understand determinants of CAUTI in long-term catheter users and factors which might influence or prevent its occurrence. Increased confidence (self-efficacy) and self-management behaviors to promote fluid intake could be of value in long-term urinary catheter users to decrease catheter blockage. PMID:26938358
State of the art of CO laser angioplasty system
NASA Astrophysics Data System (ADS)
Arai, Tsunenori; Mizuno, Kyoichi; Miyamoto, Akira; Sakurada, Masami; Kikuchi, Makoto; Kurita, Akira; Nakamura, Haruo; Takaoka, Hidetsugu; Utsumi, Atsushi; Takeuchi, Kiyoshi
1994-07-01
A unique percutaneous transluminal coronary angioplasty system new IR therapy laser with IR glass fiber delivery under novel angioscope guidance was described. Carbon monoxide (CO) laser emission of 5 mm in wavelength was employed as therapy laser to achieve precise ablation of atheromatous plaque with a flexible As-S IR glass fiber for laser delivery. We developed the first medical CO laser as well as As-S IR glass fiber cable. We also developed 5.5 Fr. thin angioscope catheter with complete directional manipulatability at its tip. The system control unit could manage to prevent failure irradiations and fiber damages. This novel angioplasty system was evaluated by a stenosis model of mongrel dogs. We demonstrated the usefulness of our system to overcome current issues on laser angioplasty using multifiber catheter with over-the-guidewire system.
Prophylactic teicoplanin during insertion of Hickman catheters.
Lim, S H; Smith, M P; Machin, S J; Goldstone, A H
1990-12-01
With the extensive use of Hickman catheters in patients requiring cytotoxic chemotherapy there is now a resurgence of Gram-positive septicaemia among these patients during the neutropenic periods. We are currently running a prospective randomized study of prophylactic teicoplanin during insertion of Hickman catheters to determine if it reduces the incidence of Gram-positive septicaemia. A total of 44 patients have completed the study (23 in the teicoplanin group and 21 in the control group). The diagnoses were: acute myelogenous leukaemia (13), non-Hodgkin's lymphoma (16), Hodgkin's disease (11), chronic granulocytic leukaemia (3) and acute lymphoblastic leukaemia (1). The number of days between insertion of Hickman catheters and the development of neutropenia was: teicoplanin group: mean 14.7, median 11, range 0-53; control group: mean 11.8, median 10, range 0-37. In the treated patients, there were four episodes of line-associated Gram-positive septicaemia and a total of four organisms were isolated. In the control group, 10 organisms were isolated from a total of nine episodes of line-associated Gram-positive septicaemia. The organisms were: coagulase-negative staphylococci (8), Streptococcus B, (1), Strep. faecalis (1), Strep. mitis (1), alpha streptococcus (1), diphtheriods (1) and Staphylococcus aureus (1). All organisms were sensitive to teicoplanin. No adverse reaction was observed in any patient. Prophylactic teicoplanin during insertion of Hickman catheters may therefore reduce the incidence of line-associated Gram-positive septicaemia in neutropenic patients.
Assessment of the functional significance of coronary lesions using a monorail catheter.
Briguori, C; Nishida, T; Adamian, M; Anzuini, A; Corvaja, N; Carlino, M; Colombo, A
2001-04-01
Myocardial fractional flow reserve (FFR) < 0.75 is a reliable index of a functionally severe coronary stenosis. FFR is best assessed by a sensor-tipped pressure monitoring guidewire (PW). The purpose of this study was to assess whether a multifunctional probing catheter (MFP), a 3 French dual-lumen monorail catheter, can be used to accurately measure intracoronary pressure and FFR. In 35 lesions (35 patients; learning group), we calculated FFR by both PW (FFRPW) and MFP (FFRMFP). Using ROC analysis, the FFRMFP value of 0.65 had the highest sensitivity with the FFRPW < 0.75. FFRMFP cut-off (0.65) was tested in 40 patients (testing group). In all cases, lumen diameter was documented by an intracoronary ultrasound examination. In the learning group, the FFRPW was 0.82 +/- 0.17 and FFRMFP was 0.70 +/- 0.23 (r = 0.88; p < 0.001). The FFRMFP cut-off value (0.65) correctly predicted the FFRPW in 37/40 cases in the testing group. In the 3 discordant cases, FFR was critical (< 0.65) by MFP and normal (> 0.75) by PW. In all these cases, minimal lumen cross-sectional area was < 2.8 mm2. When FFRMFP is > 0.65, FFRPW is always > 0.75. These data demonstrate that even with larger cross-sectional area than a pressure wire, the MFP catheter can easily and reliably be used to assess the functional severity of coronary stenosis.
Bishai, John M; Blood, Arlin B; Hunter, Christian J; Longo, Lawrence D; Power, Gordon G
2003-01-01
This study was undertaken to compare microsphere and laser Doppler flowmetry techniques for the measurement of cerebral blood flow, to assess the effect of probe implantation at the tip of the sensing probe and to measure brain tissue PO2 (tPO2) in response to acute hypoxia. Fetal sheep of ≈131 days gestation (n = 8) were chronically instrumented with bilateral laser Doppler probes in the parietal cortices and catheters for injection of fluorescent microspheres. Five days after surgery fetuses were subjected to 1 h periods of baseline control breathing, hypoxia and recovery. Microspheres were injected 10 min prior to and 10, 30, 50 and 120 min after initiation of hypoxia. Microspheres were counted in four 12 mm3 tissue samples from each hemisphere, the tip of the laser Doppler probe being positioned in the centre of one of the cubes. The cube containing the probe tip was also subdivided into 4 mm3 pieces of tissue. In response to hypoxia, fetal arterial PO2 declined from 21 ± 2 to 12 ± 1 Torr and brain tissue PO2 fell from 10 ± 1 to a nadir of 1 ± 1 Torr. Each method detected a significant increase in CBF that reached a maximum after 30–45 min, although the increase of flow measured by laser Doppler flowmetry was less than that measured by spheres after 10 and 30 min (P < 0.05). Microspheres did not detect altered flow at the probe tip or heterogeneity of flow in surrounding volumes of cortical tissue. In summary, laser Doppler flowmetry is a useful measure of continuous relative changes of CBF in the chronically instrumented fetal sheep. Flow compensations in acute hypoxia are not adequate to sustain O2 delivery, and other compensations, including reduced metabolic rate, are possible. PMID:12563011
Svoboda, A; Lo, Y; Sheu, R; Dumane, V; Rosenzweig, K
2012-06-01
To present our experience using CT to plan and verify intraluminal HDR treatment for a patient with obstructive jaundice. Due to the obstruction's proximity to the small bowel, along with small bowel adhesions from past surgical history, it was imperative to verify source position relative to the bowel before each treatment. Treatment was administered to a total dose of 2000cGy in 5 fractions via a 6F intraluminal catheter inserted into the patient's 14F percutaneous drainage catheter. Graduations on the intraluminal catheter were used to measure the exact length of catheter inserted in to the patient's drainage tube allowing reproducibility. Dummy seeds inserted during CT were identified by iteratively aligning the planning system's 3D reconstruction axis to the catheter at multiple points as it snaked through the liver. Taking in to account the known offset between actual dwell positions and dummy source positions, we determined what dwell positions to activate for planning. CT verification was performed prior to each treatment to insure that the drainage catheter had not moved and that the distance from treatment site to small bowel was adequate. Dummy seeds and anatomical landmarks were identified on the scout image and correlated to the CT. Verification CTs showed remarkable consistency in the day-to-day drainage catheter position. The physician was able to easily identify the small bowel of concern on the CT and determine if a safe distance existed for treatment. The method outlined in this work provides a safe means by which to treat bile duct obstructions using HDR when critical structures are nearby. We were prepared to make real-time adjustments to our treatment plan to account for significant variation, but found it unnecessary to do so in this particular case. © 2012 American Association of Physicists in Medicine.
In vivo dose verification method in catheter based high dose rate brachytherapy.
Jaselskė, Evelina; Adlienė, Diana; Rudžianskas, Viktoras; Urbonavičius, Benas Gabrielis; Inčiūra, Arturas
2017-12-01
In vivo dosimetry is a powerful tool for dose verification in radiotherapy. Its application in high dose rate (HDR) brachytherapy is usually limited to the estimation of gross errors, due to inability of the dosimetry system/ method to record non-uniform dose distribution in steep dose gradient fields close to the radioactive source. In vivo dose verification in interstitial catheter based HDR brachytherapy is crucial since the treatment is performed inserting radioactive source at the certain positions within the catheters that are pre-implanted into the tumour. We propose in vivo dose verification method for this type of brachytherapy treatment which is based on the comparison between experimentally measured and theoretical dose values calculated at well-defined locations corresponding dosemeter positions in the catheter. Dose measurements were performed using TLD 100-H rods (6 mm long, 1 mm diameter) inserted in a certain sequences into additionally pre-implanted dosimetry catheter. The adjustment of dosemeter positioning in the catheter was performed using reconstructed CT scans of patient with pre-implanted catheters. Doses to three Head&Neck and one Breast cancer patient have been measured during several randomly selected treatment fractions. It was found that the average experimental dose error varied from 4.02% to 12.93% during independent in vivo dosimetry control measurements for selected Head&Neck cancer patients and from 7.17% to 8.63% - for Breast cancer patient. Average experimental dose error was below the AAPM recommended margin of 20% and did not exceed the measurement uncertainty of 17.87% estimated for this type of dosemeters. Tendency of slightly increasing average dose error was observed in every following treatment fraction of the same patient. It was linked to the changes of theoretically estimated dosemeter positions due to the possible patient's organ movement between different treatment fractions, since catheter reconstruction was performed for the first treatment fraction only. These findings indicate potential for further average dose error reduction in catheter based brachytherapy by at least 2-3% in the case that catheter locations will be adjusted before each following treatment fraction, however it requires more detailed investigation. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
The effect of elastic modulus on ablation catheter contact area.
Camp, Jon J; Linte, Cristian A; Rettmann, Maryam E; Sun, Deyu; Packer, Douglas L; Robb, Richard A; Holmes, David R
2015-02-21
Cardiac ablation consists of navigating a catheter into the heart and delivering RF energy to electrically isolate tissue regions that generate or propagate arrhythmia. Besides the challenges of accurate and precise targeting of the arrhythmic sites within the beating heart, limited information is currently available to the cardiologist regarding intricate electrode-tissue contact, which directly impacts the quality of produced lesions. Recent advances in ablation catheter design provide intra-procedural estimates of tissue-catheter contact force, but the most direct indicator of lesion quality for any particular energy level and duration is the tissue-catheter contact area, and that is a function of not only force, but catheter pose and material elasticity as well. In this experiment, we have employed real-time ultrasound (US) imaging to determine the complete interaction between the ablation electrode and tissue to accurately estimate contact, which will help to better understand the effect of catheter pose and position relative to the tissue. By simultaneously recording tracked position, force reading and US image of the ablation catheter, the differing material properties of polyvinyl alcohol cryogel [1] phantoms are shown to produce varying amounts of tissue depression and contact area (implying varying lesion quality) for equivalent force readings. We have shown that the elastic modulus significantly affects the surface-contact area between the catheter and tissue at any level of contact force. Thus we provide evidence that a prescribed level of catheter force may not always provide sufficient contact area to produce an effective ablation lesion in the prescribed ablation time.
Reliability of Waveform Analysis as an Adjunct to Loss of Resistance for Thoracic Epidural Blocks.
Leurcharusmee, Prangmalee; Arnuntasupakul, Vanlapa; Chora De La Garza, Daniel; Vijitpavan, Amorn; Ah-Kye, Sonia; Saelao, Abhidej; Tiyaprasertkul, Worakamol; Finlayson, Roderick J; Tran, De Q H
2015-01-01
The epidural space is most commonly identified with loss of resistance (LOR). Although sensitive, LOR lacks specificity, as cysts in interspinous ligaments, gaps in ligamentum flavum, paravertebral muscles, thoracic paravertebral spaces, and intermuscular planes can yield nonepidural LOR. Epidural waveform analysis (EWA) provides a simple confirmatory adjunct for LOR. When the needle is correctly positioned inside the epidural space, measurement of the pressure at its tip results in a pulsatile waveform. In this observational study, we set out to assess the sensitivity, specificity, as well as positive and negative predictive values of EWA for thoracic epidural blocks. We enrolled a convenience sample of 160 patients undergoing thoracic epidural blocks for thoracic surgery, abdominal surgery, or rib fractures. The choice of patient position (sitting or lateral decubitus), approach (midline or paramedian), and LOR medium (air or normal saline) was left to the operator (attending anesthesiologist, fellow, or resident). After obtaining a satisfactory LOR, the operator injected 5 mL of normal saline through the epidural needle. A sterile tubing, connected to a pressure transducer, was attached to the needle to measure the pressure at the needle tip. A 4-mL bolus of lidocaine 2% with epinephrine 5 μg/mL was then administered and, after 10 minutes, the patient was assessed for sensory blockade to ice. The failure rate (incorrect identification of the epidural space with LOR) was 23.1%. Of these 37 failed epidural blocks, 27 provided no sensory anesthesia at 10 minutes. In 10 subjects, the operator was unable to thread the catheter through the needle. When compared with the ice test, the sensitivity, specificity, and positive and negative predictive values of EWA were 91.1%, 83.8%, 94.9%, and 73.8%, respectively. Epidural waveform analysis (with pressure transduction through the needle) provides a simple adjunct to LOR for thoracic epidural blocks. Although its use was devoid of complications, further confirmatory studies are required before its routine implementation in clinical practice.
Guo, Jin; Guo, Shuxiang; Tamiya, Takashi; Hirata, Hideyuki; Ishihara, Hidenori
2016-03-01
An Internet-based tele-operative robotic catheter operating system was designed for vascular interventional surgery, to afford unskilled surgeons the opportunity to learn basic catheter/guidewire skills, while allowing experienced physicians to perform surgeries cooperatively. Remote surgical procedures, limited by variable transmission times for visual feedback, have been associated with deterioration in operability and vascular wall damage during surgery. At the patient's location, the catheter shape/position was detected in real time and converted into three-dimensional coordinates in a world coordinate system. At the operation location, the catheter shape was reconstructed in a virtual-reality environment, based on the coordinates received. The data volume reduction significantly reduced visual feedback transmission times. Remote transmission experiments, conducted over inter-country distances, demonstrated the improved performance of the proposed prototype. The maximum error for the catheter shape reconstruction was 0.93 mm and the transmission time was reduced considerably. The results were positive and demonstrate the feasibility of remote surgery using conventional network infrastructures. Copyright © 2015 John Wiley & Sons, Ltd.
Lillaney, Prasheel V.; Yang, Jeffrey K.; Losey, Aaron D.; Martin, Alastair J.; Cooke, Daniel L.; Thorne, Bradford R. H.; Barry, David C.; Chu, Andrew; Stillson, Carol; Do, Loi; Arenson, Ronald L.; Saeed, Maythem; Wilson, Mark W.
2016-01-01
Purpose To assess the feasibility of a magnetically assisted remote-controlled (MARC) catheter system under magnetic resonance (MR) imaging guidance for performing a simple endovascular procedure (ie, renal artery embolization) in vivo and to compare with x-ray guidance to determine the value of MR imaging guidance and the specific areas where the MARC system can be improved. Materials and Methods In concordance with the Institutional Animal Care and Use Committee protocol, in vivo renal artery navigation and embolization were tested in three farm pigs (mean weight 43 kg ± 2 [standard deviation]) under real-time MR imaging at 1.5 T. The MARC catheter device was constructed by using an intramural copper-braided catheter connected to a laser-lithographed saddle coil at the distal tip. Interventionalists controlled an in-room cart that delivered electrical current to deflect the catheter in the MR imager. Contralateral kidneys were similarly embolized under x-ray guidance by using standard clinical catheters and guidewires. Changes in renal artery flow and perfusion were measured before and after embolization by using velocity-encoded and perfusion MR imaging. Catheter navigation times, renal parenchymal perfusion, and renal artery flow rates were measured for MR-guided and x-ray–guided embolization procedures and are presented as means ± standard deviation in this pilot study. Results Embolization was successful in all six kidneys under both x-ray and MR imaging guidance. Mean catheterization time with MR guidance was 93 seconds ± 56, compared with 60 seconds ± 22 for x-ray guidance. Mean changes in perfusion rates were 4.9 au/sec ± 0.8 versus 4.6 au/sec ± 0.6, and mean changes in renal flow rate were 2.1 mL/min/g ± 0.2 versus 1.9 mL/min/g ± 0.2 with MR imaging and x-ray guidance, respectively. Conclusion The MARC catheter system is feasible for renal artery catheterization and embolization under real-time MR imaging in vivo, and quantitative physiologic measures under MR imaging guidance were similar to those measured under x-ray guidance, suggesting that the MARC catheter system could be used for endovascular procedures with interventional MR imaging. © RSNA, 2016 PMID:27019290
Lillaney, Prasheel V; Yang, Jeffrey K; Losey, Aaron D; Martin, Alastair J; Cooke, Daniel L; Thorne, Bradford R H; Barry, David C; Chu, Andrew; Stillson, Carol; Do, Loi; Arenson, Ronald L; Saeed, Maythem; Wilson, Mark W; Hetts, Steven W
2016-10-01
Purpose To assess the feasibility of a magnetically assisted remote-controlled (MARC) catheter system under magnetic resonance (MR) imaging guidance for performing a simple endovascular procedure (ie, renal artery embolization) in vivo and to compare with x-ray guidance to determine the value of MR imaging guidance and the specific areas where the MARC system can be improved. Materials and Methods In concordance with the Institutional Animal Care and Use Committee protocol, in vivo renal artery navigation and embolization were tested in three farm pigs (mean weight 43 kg ± 2 [standard deviation]) under real-time MR imaging at 1.5 T. The MARC catheter device was constructed by using an intramural copper-braided catheter connected to a laser-lithographed saddle coil at the distal tip. Interventionalists controlled an in-room cart that delivered electrical current to deflect the catheter in the MR imager. Contralateral kidneys were similarly embolized under x-ray guidance by using standard clinical catheters and guidewires. Changes in renal artery flow and perfusion were measured before and after embolization by using velocity-encoded and perfusion MR imaging. Catheter navigation times, renal parenchymal perfusion, and renal artery flow rates were measured for MR-guided and x-ray-guided embolization procedures and are presented as means ± standard deviation in this pilot study. Results Embolization was successful in all six kidneys under both x-ray and MR imaging guidance. Mean catheterization time with MR guidance was 93 seconds ± 56, compared with 60 seconds ± 22 for x-ray guidance. Mean changes in perfusion rates were 4.9 au/sec ± 0.8 versus 4.6 au/sec ± 0.6, and mean changes in renal flow rate were 2.1 mL/min/g ± 0.2 versus 1.9 mL/min/g ± 0.2 with MR imaging and x-ray guidance, respectively. Conclusion The MARC catheter system is feasible for renal artery catheterization and embolization under real-time MR imaging in vivo, and quantitative physiologic measures under MR imaging guidance were similar to those measured under x-ray guidance, suggesting that the MARC catheter system could be used for endovascular procedures with interventional MR imaging. (©) RSNA, 2016.
Initial experience with the Europass: a new ultra-low profile monorail balloon catheter.
Zimarino, M; Corcos, T; Favereau, X; Tamburino, C; Toussaint, M; Spaulding, C; Guérin, Y
1994-09-01
One of the causes for percutaneous transluminal coronary angioplasty (PTCA) failure is the inability to cross the lesion with the balloon catheter after guidewire positioning. The Europass coronary angioplasty catheter is a monorail Duralyn balloon catheter developed to enhance lesion crossability and to overcome this limitation. This system was evaluated in 50 patients in which target lesions were chronic total coronary occlusions (12 cases) or stenoses that could not be reached or crossed by other new monorail balloon catheters. Overall procedural success was obtained in 49/50 patients (98%), using a single Europass balloon catheter in 46/50 patients (92%), with no in-hospital complications. Its low profile, small distal shaft, and excellent trackability allowed successful angioplasty in cases where other catheters failed. This balloon catheter represents a significant advance in angioplasty technology and can be considered as a first-choice device for a safe and expeditious single-operator procedure.
Vadmann, Henrik; Pedersen, Susanne S; Nielsen, Jens Cosedis; Rodrigo-Domingo, Maria; Pehrson, Steen; Johannessen, Arne; Hansen, Peter Steen; Johansen, Jens Brock; Riahi, Sam
2015-10-01
Catheter ablation for atrial fibrillation (AF) is an important but expensive procedure that is the subject of some debate. Physicians' attitudes toward catheter ablation may influence promotion and patient acceptance. This is the first study to examine the attitudes of Danish cardiologists toward catheter ablation for AF, using a nationwide survey. We developed a purpose-designed questionnaire to evaluate attitudes toward catheter ablation for AF that was sent to all Danish cardiologists (n = 401; response n = 272 (67.8%)). There was no association between attitudes toward ablation and the experience or age of the cardiologist with respect to patients with recurrent AF episodes with a duration of <48 hours or >7 days and/or need for cardioversion. The majority (69%) expected a recurrence of AF after catheter ablation in more than 30% of the cases. For patients with persistent longstanding AF with a duration of >1 year, the attitude toward ablation for longstanding AF was more likely to be positive with increasing age (P < 0.01) and years of experience of the cardiologist (P = 0.002). Danish cardiologists generally have a positive attitude toward catheter ablation for AF, maintain up-to-date knowledge of the procedure, and are aware what information on ablation treatment should be given to patients with AF. The cardiologists had a positive attitude toward ablation for AF in patients with AF episodes <48 hours and patients with episodes >7 days, or those who needed medical/electrical conversion, but a more negative attitude toward treating longstanding AF patients. © 2015 Wiley Periodicals, Inc.
Oudiz, Ronald J; Widlitz, Allison; Beckmann, X Joy; Camanga, Daisy; Alfie, Jose; Brundage, Bruce H; Barst, Robyn J
2004-07-01
To determine the incidence of catheter-related infection in patients with pulmonary arterial hypertension (PAH) receiving epoprostenol (EPO), and to note an etiologic role for Micrococcus spp, which is rarely reported as a pathogen in the medical literature. Observational study. Two PAH specialty treatment centers, Harbor-UCLA Medical Center (Torrance, CA), and the College of Physicians and Surgeons, Columbia University (New York, NY). A total of 192 patients with PAH receiving continuous therapy with IV EPO. From 1987 to 2000, 192 patients with PAH received infusions of EPO via central venous catheter. Catheter care included regular dressing changes with dry gauze using a sterile procedure, without the use of flushes. Patients were asked to report on known infections and treatments, and symptoms. All infections were verified by a telephone call to the patient, care provider, and microbiology laboratory whenever possible. There were 335,285 catheter days (mean +/- SD, 1,325 +/- 974 catheter days). There were 88 clinical catheter infections with 51 blood culture-positive infections, necessitating catheter removal in 38 instances. The following pathogens were isolated: Staphylococcus aureus (25); Micrococcus spp (14); mixed flora (3); coagulase-negative Staphylococcus spp (2); Corynebacterium spp (2); Serratia marcessens (1); Enterobacter spp (1); Pseudomonas aeruginosa (1); enterococci (1); and unidentified Gram-positive cocci (1). The catheter infection rate was 0.26 per 1,000 catheter days. The use of long-term therapy with continuous EPO appears to be associated with a low incidence of catheter-related infections. Micrococcus spp were the second most common etiologic agent. Caregivers managing patients with PAH must be aware of the risk of catheter infection, as it may contribute to the morbidity and mortality associated with the use of EPO. When isolated, Micrococcus spp should not be viewed as a contaminant, but rather as a true pathogen that may require therapeutic intervention.
Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M; Borm, Paul J; Jacob, Augustinus L; Bilecen, Deniz
2009-04-01
Demonstrate the usability of a new polyetheretherketone (PEEK)-based MR-compatible guidewire for renal artery catheterization, angioplasty, and stenting under MR-guidance using MR-visible markers, in vitro and in vivo. The new 0.035'' guidewire with fiber-reinforced PEEK core, a soft tip, and a hydrophilic coating was used. Paramagnetic markings were coated on the wire and nonbraided catheters for passive visualization. Bending stiffness of the guidewire was compared with available hydrophilic guidewires (Terumo Glidewire Stiff and Standard). A human aortic silicon phantom and 2 pigs were used. The study was animal care and use approved by the committee. Under MR-guidance, renal arteries were catheterized, balloon angioplasty was performed, and balloon expandable renal artery stents were deployed in vivo. Post mortem autopsy was performed. Guidewire visibility, pushability, steerability, and device-support capabilities of the marked guidewire were qualitatively assessed. Procedure times were recorded. Bending stiffness of the new PEEK-based wire was comparable with Standard Glidewire. In vitro and in vivo guidewire guidance, catheter configuration, renal artery catheterization, and balloon angioplasty were successful. In pigs, stent deployments were successful in both renal arteries. Autopsy revealed acceptable stent positioning. Guidewire visibility through applied markers was acceptable. Steerability, pushability, and device support were good in vitro and in vivo. The PEEK-based guide allows percutaneous MR-guided renal artery angioplasty and stenting with sufficient visibility, good steerability, pushability, and device support.
Experimental and Numerical Modeling of Aerosol Delivery for Preterm Infants
Lopez-Arraiza, Alberto; Rey-Santano, Carmen; Mielgo, Victoria; Basterretxea, Francisco Jose; Sancho, Javier; Gomez-Solaetxe, Miguel Angel
2018-01-01
Respiratory distress syndrome (RDS) represents one of the major causes of mortality among preterm infants, and the best approach to treat it is an open research issue. The use of perfluorocarbons (PFC) along with non-invasive respiratory support techniques has proven the usefulness of PFC as a complementary substance to achieve a more homogeneous surfactant distribution. The aim of this work was to study the inhaled particles generated by means of an intracorporeal inhalation catheter, evaluating the size and mass distribution of different PFC aerosols. In this article, we discuss different experiments with the PFC perfluorodecalin (PFD) and FC75 with a driving pressure of 4–5 bar, evaluating properties such as the aerodynamic diameter (Da), since its value is directly linked to particle deposition in the lung. Furthermore, we develop a numerical model with computational fluid dynamics (CFD) techniques. The computational results showed an accurate prediction of the airflow axial velocity at different downstream positions when compared with the data gathered from the real experiments. The numerical validation of the cumulative mass distribution for PFD particles also confirmed a closer match with the experimental data measured at the optimal distance of 60 mm from the catheter tip. In the case of FC75, the cumulative mass fraction for particles above 10 µm was considerable higher with a driving pressure of 5 bar. These numerical models could be a helpful tool to assist parametric studies of new non-invasive devices for the treatment of RDS in preterm infants. PMID:29495619
NASA Astrophysics Data System (ADS)
Mallas, Georgios; Brooks, Dana H.; Rosenthal, Amir; Vinegoni, Claudio; Calfon, Marcella A.; Razansky, R. Nika; Jaffer, Farouc A.; Ntziachristos, Vasilis
2011-03-01
Intravascular Near-Infrared Fluorescence (NIRF) imaging is a promising imaging modality to image vessel biology and high-risk plaques in vivo. We have developed a NIRF fiber optic catheter and have presented the ability to image atherosclerotic plaques in vivo, using appropriate NIR fluorescent probes. Our catheter consists of a 100/140 μm core/clad diameter housed in polyethylene tubing, emitting NIR laser light at a 90 degree angle compared to the fiber's axis. The system utilizes a rotational and a translational motor for true 2D imaging and operates in conjunction with a coaxial intravascular ultrasound (IVUS) device. IVUS datasets provide 3D images of the internal structure of arteries and are used in our system for anatomical mapping. Using the IVUS images, we are building an accurate hybrid fluorescence-IVUS data inversion scheme that takes into account photon propagation through the blood filled lumen. This hybrid imaging approach can then correct for the non-linear dependence of light intensity on the distance of the fluorescence region from the fiber tip, leading to quantitative imaging. The experimental and algorithmic developments will be presented and the effectiveness of the algorithm showcased with experimental results in both saline and blood-like preparations. The combined structural and molecular information obtained from these two imaging modalities are positioned to enable the accurate diagnosis of biologically high-risk atherosclerotic plaques in the coronary arteries that are responsible for heart attacks.
Closed loop control of a cylindrical tube type Ionic Polymer Metal Composite (IPMC)
NASA Astrophysics Data System (ADS)
Mead, Benjamin T.
The goal of this research is to provide a framework for the integration of tube type, cylindrical Ionic Polymer Metal-Composite (IPMC) into conventional devices. IPMCs are one of the most widely used types of electro-active polymer actuator, due to their low electric driving potential and large deformation range. For this research a tube type IPMC was investigated. This IPMC has a circular cross section with four separate electrodes on its surface and a hole through the middle. The four electrodes allow for biaxial bending and accurate control of the tip location. One of the main advantages of using this type of IPMC is the ability to embed a specific tool and accurately control the tool tip location using the large deflection range of the IPMC. This ability has widespread applications including in the biomedical field for use in active catheter procedures. First, this relatively new type of IPMC is investigated and characterized. The processes and materials used are described and the functional design is explored. Before the modeling process beings the basic functions of the IPMC are investigated. To this end force and displacement experiments are performed to describe the activation of the tube type IPMC. This data will be used later to verify and calibrate the mathematical simulations. Second, a three dimensional multi-physics finite element model is developed using COMSOL 4.3a. This model will automatically couple three physics packages and provide a description of the fluid interactions within the tube type IPMC. This model is then compared against the experimental displacement results to calibrate the simulation. Using this simulation design parameters are declared including, overall diameter, and tool hole size. The performance of the IPMC is then simulated while varying these parameters. Third, an electro-mechanical model of the IPMC is developed. This macroscopic model is used to relate the input voltage to an associated tip deflection. Several model types used for this purpose are tested and discussed. After determining a suitable type a mathematical electro-mechanical model is developed. Using this model several closed loop control systems are proposed. Once a final decision is reached the closed loop control system is implemented in the experimental setup. Several tests are designed to test the effectiveness of the closed loop system and mathematical models. Finally several improvements are made to enhance the users experience using IPMCs as well as incorporating them into conventional devices. To provide a better user interface the experimental control system is extended to allow the user to input controls via a standard computer mouse. This will allow a shorter operator training time and hopefully a wider array of real world uses for IPMCs. Attempts are also made to establish permanent connections to the IPMC. A tube type IPMC is meant to be used as part of a total system. To this end soldered connections to the IPMC are made. One of the main expected applications of tube type IPMCs are as active catheters. In this application the IPMC would be placed in-line with the plastic catheter line. As a proof of concept the IPMC is installed onto the tip of a conventional catheter line.
CUA Annual Meeting Abstracts addition.
2012-08-01
: Foley catheters are assumed to drain the bladder to completion. We have previously shown that dependent loops along the drainage tubing create air-locks, which obstruct antegrade urine flow and result in un-drained residual bladder urine. We hypothesized that drainage characteristics of Foley catheters remain poorly understood by urologists and general surgeons. We conducted a nationwide survey of general surgery and urology training program faculty and residents, to assess perceptions of Foley catheter drainage. We designed a novel catheter drainage tube/bag that eliminates air-locks. : An anonymous illustrated questionnaire assessing Foley catheter use patterns and perception was sent to general surgery and urology residency programs (N=108) nationwide. A modified catheter drainage tube/bag unit was designed and tested. An ex vivo catheterized bladder model was designed to measure and compare urine drainage rates with the standard drainage system, versus with our novel design. : A total of 307 responses were collected from residents (55%) and faculty (45%); responses were similar among both groups (p<0.05). The majority reported that at their centers Foley catheter drainage tubes are generally positioned with a dependent loop (94.1%), and, that positioning with a dependent loop, versus without (78.1%) promoted optimal drainage. Antegrade drainage does not occur with a traditional drainage system when a >5.5 inch dependent loop in place. With our proposed design, which eliminates dependent loops, the bladder model emptied to completion consistently. : Traditional Foley catheter drainage systems, as commonly used, evacuate the bladder sub- optimally. More reliable and complete bladder drainage may decrease the incidence of catheter related UTI. The novel modified Foley catheter drainage tube/bag design presented here eliminates dependent loops, to optimize antegrade drainage.
Ultrasound-guided transhepatic puncture of the hepatic veins for TIPS placement.
Gazzera, C; Fonio, P; Gallesio, C; Camerano, F; Doriguzzi Breatta, A; Righi, D; Veltri, A; Gandini, G
2013-04-01
This retrospective analysis was carried out to assess the feasibility and results of transjugular intrahepatic portal systemic shunt (TIPS) performed with ultrasound (US)-guided percutaneous puncture of the hepatic veins. Over a period of 3 years, 153 patients were treated with TIPS at our centre. In eight cases, a percutaneous puncture of the middle (n=7) or right (n=1) hepatic vein was required because the hepatic vein ostium was not accessible. Indications for TIPS were bleeding (n=1), Budd-Chiari syndrome (n=1), ascites (n=2), reduced portal flow (n=1) and incomplete portal thrombosis (n=3). A 0.018-in. guidewire was anterogradely introduced into the hepatic vein to the inferior vena cava (IVC) through a 21-gauge needle. In the meantime, a 25-mm snare-loop catheter was introduced through the jugular access to retrieve the guidewire, achieving through-andthrough access. Then, a Rosch-Uchida set was used to place the TIPS with the traditional technique. Technical success was achieved in all patients. There was one case of stent thrombosis. One patient died of pulmonary oedema. Three patients were eligible for liver transplantation, whereas the others were excluded due to shunt thrombosis (n=1) and previous nonhepatic neoplasms (n=3). The percutaneous approach to hepatic veins is rapid and safe and may be useful for avoiding traumatic liver injuries.
Determining the best catheter for sonohysterography.
Dessole, S; Farina, M; Capobianco, G; Nardelli, G B; Ambrosini, G; Meloni, G B
2001-09-01
To compare the characteristics of six different catheters for performing sonohysterography (SHG) to identify those that offer the best compromise between reliability, tolerability, and cost. Prospective study. University hospital. Six hundred ten women undergoing SHG. We performed SHG with six different types of catheters: Foleycath (Wembley Rubber Products, Sepang, Malaysia), Hysca Hysterosalpingography Catheter (GTA International Medical Devices S.A., La Caleta D.N., Dominican Republic), H/S Catheter Set (Ackrad Laboratories, Cranford, NJ), PBN Balloon Hystero-Salpingography Catheter (PBN Medicals, Stenloese, Denmark), ZUI-2.0 Catheter (Zinnanti Uterine Injection; BEI Medical System International, Gembloux, Belgium), and Goldstein Catheter (Cook, Spencer, IN). We assessed the reliability, the physician's ease of use, the time requested for the insertion of the catheter, the volume of contrast medium used, the tolerability for the patients, and the cost of the catheters. In 568 (93%) correctly performed procedures, no statistically significant differences were found among the catheters. The Foleycath was the most difficult for the physician to use and required significantly more time to position correctly. The Goldstein catheter was the best tolerated by the patients. The Foleycath was the cheapest whereas the PBN Balloon was the most expensive. The choice of the catheter must be targeted to achieving a good balance between tolerability for the patients, efficacy, cost, and the personal preference of the operator.
Milo, Scarlet; Acosta, Florianne B; Hathaway, Hollie J; Wallace, Laura A; Thet, Naing T; Jenkins, A Toby A
2018-03-23
Formation of crystalline biofilms following infection by Proteus mirabilis can lead to encrustation and blockage of long-term indwelling catheters, with serious clinical consequences. We describe a simple sensor, placed within the catheter drainage bag, to alert of impending blockage via a urinary color change. The pH-responsive sensor is a dual-layered polymeric "lozenge", able to release the self-quenching dye 5(6)-carboxyfluorescein in response to the alkaline urine generated by the expression of bacterial urease. Sensor performance was evaluated within a laboratory model of the catheterized urinary tract, infected with both urease positive and negative bacterial strains under conditions of established infection, achieving an average "early warning" of catheter blockage of 14.5 h. Signaling only occurred following infection with urease positive bacteria. Translation of these sensors into a clinical environment would allow appropriate intervention before the occurrence of catheter blockage, a problem for which there is currently no effective control method.
Central venous catheter-related bloodstream infections in the intensive care unit
Patil, Harsha V.; Patil, Virendra C.; Ramteerthkar, M. N.; Kulkarni, R. D.
2011-01-01
Context: Central venous catheter-related bloodstream infection (CRBSI) is associated with high rates of morbidity and mortality in critically ill patients. Aims: This study was conducted to determine the incidence of central venous catheter-related infections (CRIs) and to identify the factors influencing it. So far, there are very few studies that have been conducted on CRBSI in the intensive care unit in India. Settings and Design: This was a prospective, observational study carried out in the medical intensive care unit (MICU) over a period of 1 year from January to December 2004. Materials and Methods: A total of 54 patients with indwelling central venous catheters of age group between 20 and 75 years were included. The catheters were cultured using the standard semiquantitative culture (SQC) method. Statistical analysis used SPSS-10 version statistical software. Results: A total of 54 CVC catheters with 319 catheter days were included in this study. Of 54 patients with CVCs studied for bacteriology, 39 (72.22%) catheters showed negative SQCs and also negative blood cultures. A total of 15 (27.77%) catheters were positive on SQC, of which 10 (18.52%) were with catheter-associated infection and four (7.41%) were with catheter-associated bacteremia; the remaining one was a probable catheter-associated bacteremia. CRIs were high among catheters that were kept in situ for more than 3 days and emergency procedures where two or more attempts were required for catheterization (P < 0.05). In multivariate analysis of covariance duration of catheter in situ for >3 days, inexperienced venupucturist, more number of attempts and emergency CVC were associated with more incidence of CVCBSIs, with P <0.02. The duration of catheter in situ was negatively correlated (-0.53) and number of attempts required to put CVC was positively correlated (+0.39) with incidence of CVCBSIs. Sixty-five percent of the isolates belonged to the CONS group (13/20). Staphylococcus epidermidis showed maximum susceptibility to amikacin, doxycycline and amoxycillin with clavulanic acid and was susceptible to vancomycin (100%). Klebsiella pneumoniae was 100% susceptible to amikacin and ciprofloxacin. Escherichia coli was susceptible to amikacin and cefotaxime. Conclusions: The overall incidence of CRI was 27.77% (15/54). Catheter-associated BSIs were 47.31 per 1000 catheter-days. CRI was low in the catheters inserted by the experienced venipuncturists, elective procedure and CVC kept in situ for ≤3 days. S. epidermidis was the most common isolate. PMID:22346032
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma Yingliang; Housden, R. James; Razavi, Reza
2013-07-15
Purpose: X-ray fluoroscopically guided cardiac electrophysiology (EP) procedures are commonly carried out to treat patients with arrhythmias. X-ray images have poor soft tissue contrast and, for this reason, overlay of a three-dimensional (3D) roadmap derived from preprocedural volumetric images can be used to add anatomical information. It is useful to know the position of the catheter electrodes relative to the cardiac anatomy, for example, to record ablation therapy locations during atrial fibrillation therapy. Also, the electrode positions of the coronary sinus (CS) catheter or lasso catheter can be used for road map motion correction.Methods: In this paper, the authors presentmore » a novel unified computational framework for image-based catheter detection and tracking without any user interaction. The proposed framework includes fast blob detection, shape-constrained searching and model-based detection. In addition, catheter tracking methods were designed based on the customized catheter models input from the detection method. Three real-time detection and tracking methods are derived from the computational framework to detect or track the three most common types of catheters in EP procedures: the ablation catheter, the CS catheter, and the lasso catheter. Since the proposed methods use the same blob detection method to extract key information from x-ray images, the ablation, CS, and lasso catheters can be detected and tracked simultaneously in real-time.Results: The catheter detection methods were tested on 105 different clinical fluoroscopy sequences taken from 31 clinical procedures. Two-dimensional (2D) detection errors of 0.50 {+-} 0.29, 0.92 {+-} 0.61, and 0.63 {+-} 0.45 mm as well as success rates of 99.4%, 97.2%, and 88.9% were achieved for the CS catheter, ablation catheter, and lasso catheter, respectively. With the tracking method, accuracies were increased to 0.45 {+-} 0.28, 0.64 {+-} 0.37, and 0.53 {+-} 0.38 mm and success rates increased to 100%, 99.2%, and 96.5% for the CS, ablation, and lasso catheters, respectively. Subjective clinical evaluation by three experienced electrophysiologists showed that the detection and tracking results were clinically acceptable.Conclusions: The proposed detection and tracking methods are automatic and can detect and track CS, ablation, and lasso catheters simultaneously and in real-time. The accuracy of the proposed methods is sub-mm and the methods are robust toward low-dose x-ray fluoroscopic images, which are mainly used during EP procedures to maintain low radiation dose.« less
Barbut, F; Soukouna, S; Lalande, V; Garcia, M-L; Neyme, D; de Gramont, A; Petit, J-C
2004-12-01
Totally implantable venous access ports (TIVAP) are valuable medical devices for long-term intravenous treatment such as parenteral nutrition, cancer chemotherapy or antiviral therapy. Implantation and use of these devices are each associated with infectious or mechanical complications. To determine the frequency of complications and to analyze bacterial contamination of different parts of TIVAP (tip, septum, internal lumen of the port). Clinical charts of patients, which TIVAP was removed between April 20th to December 31st 2003, were retrospectively reviewed. Infectious complications (local and septicemic) and non-infectious complications (i.e. obstruction, thrombosis, drug extravasation...) were defined using clinical and/or microbiological criteria. Quantitative culture from different parts of the TIVAP was performed. One hundred and ten patients (age 57 +/- 14-years-old, 94.3% cancers) were included, corresponding to 57,018 catheter-days: 39.1% had one or more non-infectious complications (density incidence: 0.86 for 1000 catheter-days). Among the 49 complications, obstruction, thrombosis, extravasations and malposition accounted for 30.6%, 30.6% 4.1% and 6% of cases. Twenty-one patients (19.1%) had an infectious complication: 11 were local and 14 were systemic (density incidence 0.43 for 1000 catheter-days). Bacteria responsible for TIVAP-associated bacteraemia were coagulase negative staphylococci (N = 2), Staphylococcus aureus susceptible to methicilline (N = 3), micrococci (N = 1), corynebacteria (N = 1) or Gram-negative bacilli (N = 8). Comparison of quantitative culture of the different parts of TIVAP with a threshold at 10(3) CFU/ml showed that culture of tip, septum and port has a sensitivity of 47.6% 57.1% and 61.9 %, respectively and a specificity of 100% 92.1% and 92.1%, respectively for the diagnosis of TIVAP infection. Complications associated to TIVAP are frequent but incidence that we have reported is comparable with previous studies. Analysis of internal lumen of the port is the most sensitive method for the diagnosis of TIVAP-associated infections.
Thiagalingam, Aravinda; D'Avila, Andre; Foley, Lori; Guerrero, J Luis; Lambert, Hendrik; Leo, Giovanni; Ruskin, Jeremy N; Reddy, Vivek Y
2010-07-01
Ablation electrode-tissue contact has been shown to be an important determinant of lesion size and safety during nonirrigated ablation but little data are available during irrigated ablation. We aimed to determine the importance of contact force during irrigated-tip ablation. Freshly excised hearts from 11 male pigs were perfused and superfused using fresh, heparinized, oxygenated swine blood in an ex vivo model. One-minute ablations were placed using one of 3 different power control strategies (impedance control-15 Omega target impedance drop, and 20 W or 30 W fixed power) and 3 different contact forces (2 g, 20 g, and 60 g) to give a grid of 9 ablation groups. The force sensing catheter (Tacticath, Endosense SA) was irrigated at 17 mL/min for all of the ablations. Of a total 101 ablations, no thrombus formation was noted but popping was seen in 17 lesions. The lesion depth and incidence of pops was 5.0 +/- 1.3 mm /0%, 5.0 +/- 1.6 mm /10% and 6.7 +/- 2.5 mm /45% for the 15 Omega, 20 W, and 30 W groups (P < 0.01), respectively, and 4.4 +/- 1.8 mm /3%, 5.8 +/- 1.6 mm /17% and 6.6 +/- 2.0 mm /37% for the 2 g, 20 g, and 60 g groups, respectively (P < 0.01). The impedance drop in the first 5 seconds was significantly correlated to catheter contact force: 9.7 +/- 9.9 Omega, 22.3 +/- 11.0 Omega, and 41.7 +/- 22.1 Omega, respectively, for the 2 g, 20 g, and 60 g groups (Pearson's r = 0.65, P < 0.01). Catheter contact force has an important impact on both ablation lesion size and the incidence of pops.
Niehaus, Wilmari L; Howlin, Robert P; Johnston, David A; Bull, Daniel J; Jones, Gareth L; Calton, Elizabeth; Mavrogordato, Mark N; Clarke, Stuart C; Thurner, Philipp J; Faust, Saul N; Stoodley, Paul
2016-09-01
Bacterial infections of central venous catheters (CVCs) cause much morbidity and mortality, and are usually diagnosed by concordant culture of blood and catheter tip. However, studies suggest that culture often fails to detect biofilm bacteria. This study optimizes X-ray micro-focus computed tomography (X-ray µCT) for the quantification and determination of distribution and heterogeneity of biofilms in in vitro CVC model systems.Bacterial culture and scanning electron microscopy (SEM) were used to detect Staphylococcus epidermidis ATCC 35984 biofilms grown on catheters in vitro in both flow and static biofilm models. Alongside this, X-ray µCT techniques were developed in order to detect biofilms inside CVCs. Various contrast agent stains were evaluated using energy-dispersive X-ray spectroscopy (EDS) to further optimize these methods. Catheter material and biofilm were segmented using a semi-automated matlab script and quantified using the Avizo Fire software package. X-ray µCT was capable of distinguishing between the degree of biofilm formation across different segments of a CVC flow model. EDS screening of single- and dual-compound contrast stains identified 10 nm gold and silver nitrate as the optimum contrast agent for X-ray µCT. This optimized method was then demonstrated to be capable of quantifying biofilms in an in vitro static biofilm formation model, with a strong correlation between biofilm detection via SEM and culture. X-ray µCT has good potential as a direct, non-invasive, non-destructive technology to image biofilms in CVCs, as well as other in vivo medical components in which biofilms accumulate in concealed areas.
Thrombotic complications of central venous catheters in cancer patients.
Kuter, David J
2004-01-01
Central venous catheters (CVCs), such as the tunneled catheters and the totally implanted ports, play a major role in general medicine and oncology. Aside from the complications (pneumothorax, hemorrhage) associated with their initial insertion, all of these CVCs are associated with the long-term risks of infection and thrombosis. Despite routine flushing with heparin or saline, 41% of CVCs result in thrombosis of the blood vessel, and this markedly increases the risk of infection. Only one-third of these clots are symptomatic. Within days of insertion, almost all CVCs are coated with a fibrin sheath, and within 30 days, most CVC-related thrombi arise. Aside from reducing the function of the catheter, these CVC-related thrombi can cause postphlebitic syndrome in 15%-30% of cases and pulmonary embolism in 11% (only half of which are symptomatic). Risk factors for CVC thrombosis include the type of malignancy, type of chemotherapy, type of CVC, and locations of insertion site and catheter tip, but not inherited thrombophilic risk factors. Efforts to reduce CVC thrombosis with systemic prophylactic anticoagulation with low-molecular-weight heparin have failed. Low-dose warfarin prophylaxis remains controversial; all studies are flawed, with older studies, but not newer ones, showing benefit. Currently, less than 10% of patients with CVCs receive any systemic prophylaxis. Although its general use cannot be recommended, low-dose warfarin may be a low-risk treatment in patients with good nutrition and adequate hepatic function. Clearly, additional studies are required to substantiate the prophylactic use of low-dose warfarin. Newer anticoagulant treatments, such as pentasaccharide and direct thrombin inhibitors, need to be explored to address this major medical problem.
Mordasini, Pasquale; Szucs-Farkas, Zsolt; Do, Do-Dai; Gralla, Jan; Kettenbach, Joachim; Hoppe, Hanno
2010-08-01
The latest-generation Amplatzer vascular plug (AVP), the AVP 4, is designed for embolization of smaller vessels without a sheath or guiding catheter. This study evaluated the AVP 4 in peripheral vascular embolization. Embolization with the AVP 4 was attempted in 13 patients (11 men) for trauma (n = 7) and other indications (n = 6). Technical success rate, vascular bed, size of catheter, and number and size of AVP 4 devices were recorded. Embolization with the AVP 4 was successful in 10 of 13 patients (77%). In trauma patients (n = 7), embolization of the splenic artery (n = 4), lumbar artery (n = 2), and superior gluteal artery (n = 1) was performed. In other patients, preoperative embolization of the right portal vein (n = 1), a gastric varix after transjugular intrahepatic portosystemic shunt creation (n = 1), an aneurysm of the internal iliac artery (n = 1), and inferior mesenteric artery (IMA) embolization before aneurysm repair (n = 2) was performed. Sizes of the AVP 4 were 4 mm (n = 6), 6 mm (n = 5), and 8 mm (n = 1). In all patients, 4- and 5-F catheters with a 0.038-inch minimum inner lumen were used. In one patient, IMA embolization was attempted via a femoral approach but was unsuccessful as a result of repeated catheter tip dislocation because of acute angle; coils were used instead. Peripheral embolization with the AVP 4 was successful in the majority of patients. Future comparative study is necessary to evaluate this device's benefits over other embolization materials such as earlier-generation AVPs or microcoils. Copyright (c) 2010 SIR. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirose, K; Takai, Y; Southern Tohoku BNCT Research Center, Koriyama
2016-06-15
Purpose: The purpose of this study was to prospectively assess the reproducibility of positioning errors due to temporarily indwelled catheter in urethra-sparing image-guided (IG) IMRT. Methods: Ten patients received urethra-sparing prostate IG-IMRT with implanted fiducials. After the first CT scan was performed in supine position, 6-Fr catheter was indwelled into urethra, and the second CT images were taken for planning. While the PTV received 80 Gy, 5% dose reduction was applied for the urethral PRV along the catheter. Additional CT scans were also performed at 5th and 30th fraction. Positions of interests (POIs) were set on posterior edge of prostatemore » at beam isocenter level (POI1) and cranial and caudal edge of prostatic urethra on the post-indwelled CT images. POIs were copied into the pre-indwelled, 5th and 30th fraction’s CT images after fiducial matching on these CT images. The deviation of each POI between pre- and post-indwelled CT and the reproducibility of prostate displacement due to catheter were evaluated. Results: The deviation of POI1 caused by the indwelled catheter to the directions of RL/AP/SI (mm) was 0.20±0.27/−0.64±2.43/1.02±2.31, respectively, and the absolute distances (mm) were 3.15±1.41. The deviation tends to be larger if closer to the caudal edge of prostate. Compared with the pre-indwelled CT scan, a median displacement of all POIs (mm) were 0.3±0.2/2.2±1.1/2.0±2.6 in the post-indwelled, 0.4±0.4/3.4±2.1/2.3±2.6 in 5th, and 0.5±0.5/1.7±2.2/1.9±3.1 in 30th fraction’s CT scan with a similar data distribution. There were 6 patients with 5-mm-over displacement in AP and/or CC directions. Conclusion: Reproducibility of positioning errors due to temporarily indwelling catheter was observed. Especially in case of patients with unusually large shifts by indwelling catheter at the planning process, treatment planning should be performed by using the pre-indwelled CT images with transferred contour of the urethra identified by post-indwelled CT images.« less
Malcolme-Lawes, Louisa C; Lim, Phang Boon; Koa-Wing, Michael; Whinnett, Zachary I; Jamil-Copley, Shahnaz; Hayat, Sajad; Francis, Darrel P; Kojodjojo, Pipin; Davies, D Wyn; Peters, Nicholas S; Kanagaratnam, Prapa
2013-01-01
Recurrent arrhythmias after ablation procedures are often caused by recovery of ablated tissue. Robotic catheter manipulation systems increase catheter tip stability which improves energy delivery and could produce more transmural lesions. We tested this assertion using bipolar voltage attenuation as a marker of lesion quality comparing robotic and manual circumferential pulmonary vein ablation for atrial fibrillation (AF). Twenty patients were randomly assigned to robotic or manual AF ablation at standard radiofrequency (RF) settings for our institution (30 W 60 s manual, 25 W 30 s robotic, R30). A separate group of 10 consecutive patients underwent robotic ablation at increased RF duration, 25 W for 60 s (R60). Lesions were marked on an electroanatomic map before and after ablation to measure distance moved and change in bipolar electrogram amplitude during RF. A total of 1108 lesions were studied (761 robotic, 347 manual). A correlation was identified between voltage attenuation and catheter movement during RF (Spearman's rho -0.929, P < 0.001). The ablation catheter was more stable during robotic RF; 2.9 ± 2.3 mm (R30) and 2.6 ± 2.2 mm (R60), both significantly less than the manual group (4.3 ± 3.0 mm, P < 0.001). Despite improved stability, there was no difference in signal attenuation between the manual and R30 group. However, there was increased signal attenuation in the R60 group (52.4 ± 19.4%) compared with manual (47.7 ± 25.4%, P = 0.01). When procedures under general anaesthesia (GA) and conscious sedation were analysed separately, the improvement in signal attenuation in the R60 group was only significant in the procedures under GA. Robotically assisted ablation has the capability to deliver greater bipolar voltage attenuation compared with manual ablation with appropriate selection of RF parameters. General anaesthesia confers additional benefits of catheter stability and greater signal attenuation. These findings may have a significant impact on outcomes from AF ablation procedures.
Cutting Head for Ultrasonic Lithotripsy
NASA Technical Reports Server (NTRS)
Angulo, E. D.; Goodfriend, R.
1987-01-01
Kidney stones lodged in urinary tract disintegrated with increased safety and efficiency by cutting head attached to end of vibrated wire probe. Aligns probe with stone and enables probe to vibrate long enough to disintegrate stone. Design of cutting head reduces risk of metal-fatigue-induced breakage of probe tip leaving metal fragments in urinary tract. Teeth of cutting head both seat and fragment kidney stone, while extension of collar into catheter lessens mechanical strain in probe wire, increasing probe life and lessening danger of in situ probe breakage.
Research on pressure sensors for biomedical instruments
NASA Technical Reports Server (NTRS)
Angell, J. B.
1975-01-01
The development of a piezo-resistive pressure transducer is discussed suitable for recording pressures typically encountered in biomedical applications. The pressure transducer consists of a thin silicon diaphragm containing four strain-sensitive resistors, and is fabricated using silicon monolithic integrated-circuit technology. The pressure transducers can be as small as 0.7 mm outer diameter, and are, as a result, suitable for mounting at the tip of a catheter. Pressure-induced stress in the diaphragm is sensed by the resistors, which are interconnected to form a Wheatstone bridge.
1991-08-14
tip will enter the superior vena cava and right atrium at different distances, denoted by the incremental markings every 10 cm on the catheter. Once...mitral valve is open, an unobstructed column of blood exists from the PA to the left atrium and the left ventricle. Therefore, pressure is approximately...Pressures measured by the distal port (PA pressure) reflect end-diastolic pressures. RA = right atrium ; RV x right ventricle, LA z left atrium ; LV = left
Herard, A; Colin, J; Youinou, Y; Drancourt, E; Brandt, B
1998-08-01
We report the case of a patient with heterozygous sickle cell trait presenting with massive gross hematuria. Ureteroscopy revealed bleeding from the tip of papilla of the inferior calica and allowed us to tamponade the bleeding with a balloon ureteral dilator set (Cook(R) Urology). We show the value of the endourological approach in the conservative management of these patients at high risk of recurrent hematuria.
A new approach in the management of the hydrocele with a silicone catheter.
Arslan, Mehmet; Kilinç, Mehmet; Yilmaz, Kadir; Oztürk, Ahmet
2004-01-01
To describe a new alternative technique to overcome several disadvantages of previous techniques to repair idiopathic hydrocele. Idiopathic hydrocele, which causes scrotal enlargement and discomfort for patients, is an abnormal fluid collection between the parietal and visceral layers of tunica vaginalis of the testis. Surgical and sclerotherapy treatments have previously been used to treat this problem. Forty-five patients with hydrocele (aged 19 to 67 years) underwent an alternative procedure using a silicone catheter 15 to 20 cm in length in which holes had been made to enable flow of the hydrocele fluid from the parietal layer of the tunica vaginalis to the surrounding scrotal tissue. After an incision of approximately 5 mm on the scrotal wall with a scalpel knife, a cannula was pushed through the hydrocele sac with a gentle rotation until reaching the upper scrotal wall. A silicone catheter with holes was passed through the cannula to the point of the incision by way of the cannula. At the end, both tips of the catheter were sutured. During the procedure, the hydrocele fluid was emptied using an angiocatheter before the cannula was removed. The results of this study indicate that this procedure does not require dissection, incision, or manipulation of the scrotal contents during treatment. It also resulted in a low rate of recurrence during the 1 to 3 years of follow-up. Additionally, the procedure has minimal complications and requires a short time, only about 15 minutes.
An assembly-type master-slave catheter and guidewire driving system for vascular intervention.
Cha, Hyo-Jeong; Yi, Byung-Ju; Won, Jong Yun
2017-01-01
Current vascular intervention inevitably exposes a large amount of X-ray to both an operator and a patient during the procedure. The purpose of this study is to propose a new catheter driving system which assists the operator in aspects of less X-ray exposure and convenient user interface. For this, an assembly-type 4-degree-of-freedom master-slave system was designed and tested to verify the efficiency. First, current vascular intervention procedures are analyzed to develop a new robotic procedure that enables us to use conventional vascular intervention devices such as catheter and guidewire which are commercially available in the market. Some parts of the slave robot which contact the devices were designed to be easily assembled and dissembled from the main body of the slave robot for sterilization. A master robot is compactly designed to conduct insertion and rotational motion and is able to switch from the guidewire driving mode to the catheter driving mode or vice versa. A phantom resembling the human arteries was developed, and the master-slave robotic system is tested using the phantom. The contact force of the guidewire tip according to the shape of the arteries is measured and reflected to the user through the master robot during the phantom experiment. This system can drastically reduce radiation exposure by replacing human effort by a robotic system for high radiation exposure procedures. Also, benefits of the proposed robot system are low cost by employing currently available devices and easy human interface.
Fluoroscopy-Guided Pull-Through Gastrostomy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pitton, M. B., E-mail: pitton@radiologie.klinik.uni-mainz.de; Herber, S.; Dueber, C.
2008-01-15
The purpose of this study was to simplify a fluoroscopy guided gastrostomy technique using pull-type tubes which are traditionally introduced with gastroscopic assistance. The stomach was transorally probed with a 5-Fr catheter and a guidewire. A second access was performed percutaneously through the anterior abdominal and gastric wall using an 8-Fr sheath and an 8-Fr guiding catheter. A duplicated guidewire was introduced through the guiding catheter in order to result in a great custom-made loop within the stomach. The transoral guidewire was captured and tightened with this loop and the guiding catheter, and both were subsequently pulled by the transoralmore » guidewire until the tip of the guiding catheter exited the mouth. A thread was fed through the guiding catheter for fixation of the pull-type gastrostomy tube. Finally, the fixed tube was pulled through the esophagus into the stomach and through the abdominal wall until the anterior gastric wall fixed the retention plate of the tube. Thirty-seven patients (28 male, 9 female; age, 65.1 {+-} 14.4 years) with miscellaneous indications for percutaneous gastrostomies were supplied with pull-type gastrostomy catheters in a fluoroscopy technique without endoscopic assistance. Twenty-five of the 37 patients (67.6%) had undergone unsuccessful preceding gastroscopically guided PEG attempts because of tumor stenosis (n = 12) or impossible transillumination of the abdominal wall (n = 13). All procedures were technically successful, without major complications. Particularly, all patients with frustrating gastroscopic attempts were successfully provided with pull-type gastrostomy tubes. Five minor complications occurred: one tube loss during the passage of the hypopoharynx because of a torn thread, one transient small leakage alongside the tube (both successfully treated), and three cases of transient moderate local pain without leakage (symptomatic treatment). We conclude that this fluoroscopy-guided pull-through gastrostomy technique is easy and safe to perform and may be suggested as a standard procedure for radiological gastrostomies. It combines the ease of the radiological approach with the advantages of the pull-type tube devices, particularly the benefits of the typical retention plates.« less
Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cunha, J. A. M.; Hsu, I-C.; Pouliot, J.
2009-01-15
Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new cathetersmore » following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V{sub 100}{sup Prostate}>90%) and organ-at-risk dose sparing (V{sub 75}{sup Bladder}<1 cc, V{sub 75}{sup Rectum}<1 cc, V{sub 125}{sup Urethra}<<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter patterns may decrease toxicity by avoidance of the critical structures near the penile bulb while still fulfilling the RTOG criteria.« less
Segura, M; Alía, C; Valverde, J; Franch, G; Torres Rodríguez, J M; Sitges-Serra, A
1990-01-01
An in vivo model of hub-related catheter sepsis in rabbits is reported. The model was used to investigate the protection offered by a new hub design against external contamination by Pseudomonas aeruginosa or Staphylococcus epidermidis and to reassess the diagnostic value of the semiquantitative culture method in bacteremia of endoluminal origin. Contamination of conventional Luer-Lock connectors was followed by clinical sepsis, positive catheter segment cultures, or both, whereas contamination of the new hub was followed by complete protection. Clinical and bacteriological discrepancies observed between contamination with P. aeruginosa and S. epidermidis suggest that the virulence of microorganisms may account for differences in the natural history of hub-originated catheter sepsis. The semiquantitative extraluminal method for catheter culture yielded less than 15 CFU in three animals with proven bacteremia and should not be used as the "gold standard" to define catheter-related bacteremia. PMID:2254430
The effects of electric current on bacteria colonising intravenous catheters.
Liu, W K; Tebbs, S E; Byrne, P O; Elliott, T S
1993-11-01
The effect of a direct electric current (10 microA) on the growth of Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, Klebsiella pneumoniae and Proteus mirabilis was investigated. When the ends of negatively-charged intravascular catheters were placed in nutrient agar seeded with bacteria, circular zones of inhibition of bacterial growth were observed around the catheters. The zones ranged from 6 to 16 mm in diameter according to the organism under test. Zones of inhibition were not produced around positively-charged catheters. Bacteria colonising the surfaces of catheters were similarly affected by the application of a 10 microA electric current. A negative electric current applied to colonised catheters for 4 to 24 h significantly reduced the number of adherent viable organisms as compared to controls. The results demonstrated that a constant electric current of low amperage might be used to reduce bacterial colonisation of intravascular catheters. This may offer a novel means of protecting catheters and other prosthetic devices from associated sepsis in vivo.
Is it feasible to diagnose catheter-related candidemia without catheter withdrawal?
Fernández-Cruz, Ana; Martín-Rabadán, Pablo; Suárez-Salas, Marisol; Rojas-Wettig, Loreto; Pérez, María Jesús; Guinea, Jesús; Guembe, María; Peláez, Teresa; Sánchez-Carrillo, Carlos; Bouza, Emilio
2014-07-01
Many bloodstream infections (BSI) in patients with central venous catheters (CVC) are not catheter-related (CR). Assessment of catheter involvement without catheter withdrawal has not been studied in candidemia. We assessed the value of conservative techniques to evaluate catheters as the origin of candidemia in patients with CVC in a prospective cohort study (superficial Gram stain and culture, Kite technique (Gram stain and culture of the first 1 cm blood drawn from the CVC), proportion of positive blood cultures (PPBCs), differential time to positivity (DTP), and minimal time to positivity (MTP)). All catheters were cultured at withdrawal. From June 2008 to January 2012, 22 cases fulfilled the inclusion criteria. CR-candidemia (CRC) was confirmed in 10. Validity values for predicting CRC were: superficial Gram stain (S, 30%; Sp, 81.83%; PPV, 60%; NPV, 56.3%; Ac, 57.1%), superficial cultures (S, 40%; Sp, 75%; PPV, 57.1%; NPV, 60%; Ac, 59.1%), Kite Gram stain (S, 33.3%; Sp, 66.7%; PPV, 50%; NPV, 50%; Ac, 50%), Kite culture (S, 80%; Sp, 66.7%; PPV, 66.7%; NPV, 80%; Ac, 72.7%), PPBC (S, 50%; Sp, 41.7%; PPV, 41.7%; NPV, 50.0%; Ac, 45.5%), DTP (S, 100%; Sp, 33.3%; PPV, 55.6%; NPV, 100%; Ac, 63.6%), and MTTP (S, 70%; Sp, 58.3%; PPV, 58.3%; NPV, 70%; Ac, 63.6%). While combinations of two tests improved sensitivity and NPV, more than two tests did not improve validity values. Classic tests to assess CR-BSI caused by bacteria cannot be reliably used to diagnose CRC. Combinations of tests could be useful, but more and larger studies are required. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Complications of intrathecal opioids and bupivacaine in the treatment of "refractory" cancer pain.
Nitescu, P; Sjöberg, M; Appelgren, L; Curelaru, I
1995-03-01
To test the concept that externalized tunneled intrathecal catheters lead to a high risk of complications, such as meningitis and epidural abscess, and therefore should not be used for durations of intrathecal pain treatment of > 1 week. Prospective, cohort, nonrandomized, consecutive, historical control trial. Tertiary care center, institutional practice, hospitalized and ambulatory care. Two hundred adults (107 women, 93 men) with refractory cancer pain treated for 1-575 (median, 33; total, 14,485) days; 79 patients were treated at home for 2-226 (median, 36; total, 4,711) days. All patients had died by the close of the study. Insertion of intrathecal tunneled nylon (Portex) catheters (223 in 200 patients) with Millipore filters. The catheter hubs were securely fixed to the skin with steel sutures. Standardized care after insertion: (a) daily phone contact with the patients, their families, or the nurses in charge; (b) weekly dressing change at the tunnel outlet by the nurses; (c) refilling of the infusion containers by the nurses; (d) exchange of the infusion systems when empty (within 1 month) and of the antibacterial filter once a month by specially instructed Pain Department nurses. All contact between the connections of the syringes, cassettes, and needles with the operator's hands was carefully avoided during filling and refilling of the infusion containers and exchange of the antibacterial filters; no other aseptic precautions were taken. We recorded the rates of perfect function and complications of the systems. The rates of complications recorded in this study with externalized tunneled intrathecal catheters are discussed and compared with the rates reported in the literature with externalized (tunneled and non-tunneled) epidural and intrathecal catheters, as well as with internalized (both epidural and intrathecal) catheters connected to subcutaneous ports, reservoirs, and pumps. The following rates (as a percentage of number of patients) of perfect function and complications of the systems were recorded (the ranges of rates reported in the literature are given in parentheses): perfect function of the system, 93% (31-90%); accidental injury of an unknown epidural tumor followed by an epidural hematoma, 0.5% (0-6%); skin breakdown at the insertion site, 2% (2-50%); postdural puncture headache, 15.5% (10%); external leakage of CSF, 3.5% (4-27%); CSF hygroma ("pseudomeningocele"), 1.5% (4-6.25%); hearing loss and Ménière-like syndrome, 0% (12%); pain on injection, 0% with continuous infusion and 4.5% with intermittent injections (3-36% with intermittent injections); catheter tip dislodgement, 1.5% (6-33%); catheter (system) occlusion, 1% (3-12%); accidental catheter withdrawal, 4% (3-22%); catheter (system) leakage, 1.5% (2.1-26.6%); all mechanical complications, 8.5% (10-44%); local (catheter entry site) infection, 0.5% (2-33%); catheter track infection, 0% (6-25%); epidural abscess, 0% (0.6-25%); meningitis, 0.5% (1-25%); systemic infection, 0% (3%); incidence of all infections (n/treatment days), 1/7,242 (1/168-1/2,446). In our population and with the technique of insertion and care reported here, the use of externalized tunneled intrathecal catheters has not been associated with higher rates of complications when compared with earlier reported rates of externalized epidural catheters and internalized (both epidural and intrathecal) catheters connected to subcutaneously implanted ports, reservoirs, and pumps. The opinion that the use of externalized tunneled intrathecal catheters should be restricted only to patients who need pain treatment for < 1 week (because of the potential risk of infection, particularly meningitis and epidural abscess) is unfounded.
Stoltz, Petronella; Manworren, Renee C B
Needle procedures, like venipuncture and intravenous (IV) catheter insertion, are recognized as a common cause of pain and fear for children in hospitals and emergency departments. The purpose of this study was to compare children's self-reported pain and fear related to IV insertion with administration of either the topical local anesthetic EMLA® or 1% buffered lidocaine delivered with the J-Tip Needleless Injection System® (J-Tip®). In this prospective, randomized trial, 150 consecutive pediatric patients 8 to 18years of age undergoing IV insertion were randomly assigned 1:1 to treatment group. Participants self-reported procedural pain using a Visual Analog Scale, and procedural fear using the Children's Fear Scale. Procedural pain scores were significantly lower in the EMLA® group (mean score 1.63+1.659) vs. the J-Tip® group (2.99±2.586; p<0.001). Post-procedure fear scores were significantly lower than pre-procedure fear scores in both treatment groups (p<0.002), but there was no difference in fear scores between the two treatment groups (p=0.314). EMLA® provided superior pain relief for IV insertion compared to J-Tip®. Although EMLA® use resulted in lower self-reported pain scores compared to J-Tip®, pain scores for both treatments were low and fear scores did not differ. When IV insertion can be delayed for 60-90min, EMLA® should be used. When a delay is contraindicated, J-Tip® may be a reasonable alternative to minimize procedural pain of IV insertion. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takizawa, Kenji, E-mail: khirari@marianna-u.ac.jp; Nakajima, Yasuo, E-mail: nakajima.yasuo@gmail.com; Ogawa, Yukihisa, E-mail: yukky.oct.22@gmail.com
Purpose: The authors devised a new method of an axial puncture approach through the pulmonary apex (PA) for percutaneous catheter drainage (PCD) of loculated fluid collections extending to the PA. The purpose of this report is to introduce the new procedure. Methods: Percutaneous catheter drainage by the axial puncture approach was performed in two patients with limited supine position and loculated pleural fluid collection in the posteromedial part of thoracic cavity. Results: The procedures succeeded in two patients without difficulties while keeping them in a supine position, even if the loculated fluids exist in the posterior side of thoracic cavity.more » Conclusions: Percutaneous catheter drainage by the axial puncture approach is particularly effective in patients with limited supine positions and loculated pleural fluid collection in the posteromedial part of thoracic cavity.« less
Deleers, M; Dodémont, M; Van Overmeire, B; Hennequin, Y; Vermeylen, D; Roisin, S; Denis, O
2016-04-01
Catheter-related bloodstream infections (CRBSIs) remain a leading cause of healthcare-associated infections in preterm infants. Rapid and accurate methods for the diagnosis of CRBSIs are needed in order to implement timely and appropriate treatment. A retrospective study was conducted during a 7-year period (2005-2012) in the neonatal intensive care unit of the University Hospital Erasme to assess the value of Gram stain on catheter-drawn blood samples (CDBS) to predict CRBSIs. Both peripheral samples and CDBS were obtained from neonates with clinically suspected CRBSI. Gram stain, automated culture and quantitative cultures on blood agar plates were performed for each sample. The paired quantitative blood culture was used as the standard to define CRBSI. Out of 397 episodes of suspected CRBSIs, 35 were confirmed by a positive ratio of quantitative culture (>5) or a colony count of CDBS culture >100 colony-forming units (CFU)/mL. All but two of the 30 patients who had a CDBS with a positive Gram stain were confirmed as having a CRBSI. Seven patients who had a CDBS with a negative Gram stain were diagnosed as CRBSI. The sensitivity, specificity, positive predictive value and negative predictive value of Gram stain on CDBS were 80, 99.4, 93.3 and 98.1 %, respectively. Gram staining on CDBS is a viable method for rapidly (<1 h) detecting CRBSI without catheter withdrawal.
Okada, Mari; Sato, Mai; Ogura, Masao; Kamei, Koichi; Matsuoka, Kentaro; Ito, Shuichi
2016-03-31
Advances in long-term parenteral nutrition via indwelling central venous catheter have improved the quality of life and mortality in patients with life-threatening gastrointestinal diseases complicated with severely impaired absorption. However, infection to central venous catheter is still a common and critical complication for such patients. We encountered two patients under long-term parenteral nutrition who developed glomerulonephritis associated with central venous catheter infection. Persistent bacterial infection in indwelling medical devices placed in the blood-stream such as a ventricular-atrial shunt is known to cause glomerulonephritis, a condition termed shunt nephritis. We reported the clinical manifestations, treatment and their pathological findings in the two patients with glomerulonephritis associated with central venous catheter infection. Both patients suffered from megacystis microcolon intestinal hypoperistalsis syndrome, a form of pseudo-Hirschsprung's disease. They had been receiving home parenteral nutrition via central venous catheter because of severe malabsorption. They presented proteinuria, hematuria, hypocomplementemia and positive PR3-antineutrophilic cytoplasmic antibody accompanied by Staphylococcus epidermidis infection in the central venous catheter. Their renal biopsy revealed membranoproliferative glomerulonephritis with positive C3 deposition. One of them recovered completely following the removal of catheter and administration of antibiotics, while another did not respond to the treatments. We then treated her with methylprednisolone pulse therapy followed by prednisolone. She responded well, and achieved complete remission. As central venous catheter infection-related glomerulonephritis has a similar etiology to shunt nephritis, removal of the catheter and administration of antibiotics is fundamental to the treatment. If a patient is resistant to such conventional therapy, additional steroid and/or immunosuppressive agent could be considered. Although the number of patients with classical shunt nephritis is decreasing since the ventricular-peritoneal shunt has become became the major procedure for hydrocephalus, central venous catheter infection-related glomerulonephritis may increase in the future due to a marked increase in the number of patients receiving long-term parenteral nutrition. Routine urinalysis should be considered in such patients for early detection of central venous catheter infection-related glomerulonephritis.
Lee, Jae Myeong; Cho, Young Kwon; Kim, Han Myun; Song, Myung Gyu; Song, Soon-Young; Yeon, Jae Woo; Yoon, Dae Young; Lee, Sam Yeol
2018-03-01
The objective of this study was to conduct a prospective clinical trial evaluating the technical feasibility and short-term clinical outcome of the blind pushing technique for placement of pretrimmed peripherally inserted central catheters (PICCs) through brachial vein access. Patients requiring PICC placement at any of the three participating institutions were prospectively enrolled between January and December 2016. The review boards of all participating institutions approved this study, and informed consent was obtained from all patients. PICC placement was performed using the blind pushing technique and primary brachial vein access. The following data were collected from unified case report forms: access vein, obstacles during PICC advancement, procedure time, and postprocedural complications. During the 12-month study period, 1380 PICCs were placed in 1043 patients. Of these, 1092 PICCs placed in 837 patients were enrolled, with 834 PICCs (76%) and 258 PICCs (34%) placed through brachial vein and nonbrachial vein access, respectively. In both arms, obstacles were most commonly noted in the subclavian veins (n = 220) and axillary veins (n = 94). Successful puncture of the access vein was achieved at first try in 1028 PICCs (94%). The technical success rate was 99%, with 1055 PICCs (97%) placed within 120 seconds of procedure time and 1088 PICCs (99%) having the tip located at the ideal position. Follow-up Doppler ultrasound detected catheter-associated upper extremity deep venous thrombosis (UEDVT) for 18 PICCs in 16 patients and late symptomatic UEDVT for 16 PICCs in 16 patients (3.1%). Catheter-associated UEDVT was noted for 28 PICCs (82%) and 6 PICCs (18%) placed through brachial vein and nonbrachial vein access, respectively. The incidence of obstacles and the procedure time (<120 seconds) differed significantly between brachial vein and nonbrachial vein access (P = .001). There was no statistically significant difference between brachial vein and nonbrachial vein access in the incidence of UEDVT (odds ratio, 0.68; 95% confidence interval, 0.59-3.52; P = .22). The placement of pretrimmed PICCs by the blind pushing technique and primary brachial vein access is technically feasible and may represent an alternative to the conventional PICC placement technique, having low incidences of UEDVT and other complications, with no significant difference in outcomes between brachial vein and nonbrachial vein access. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Seibel, Eric J.
2008-02-01
Flexible endoscopes use one sensor element per display pixel. When diameter is reduced to the size of a catheter, there is a significant reduction in the number of pixels within the image. By placing a sub-millimeter microscanner at the tip of a catheter, image quality can be significantly improved. The microscanner consists of a 0.4 mm diameter piezoelectric tube with quadrant electrodes, surrounding a cantilevered singlemode optical fiber. At the distal end, the fiber microscanner is sealed with a 0.9 mm diameter lens assembly, creating a rigid length less than 10 mm at the tip of a highly flexible shaft. The cantilevered fiber is vibrated at the first mode of resonance for bending to generate a circular scan pattern. A spiral scan pattern is generated that constitutes an image frame by modulating the piezoelectric drive signals. By using a custom optical fiber at 80 microns cladding diameter, >10 KHz resonant scanning is achieved, resulting in a 30 Hz frame rate. Red (635 nm), green (532 nm), and blue (442 nm) laser light is scanned by coupling to the fiber scanner. The scanned illumination is detected in a non-confocal arrangement by having one or more optical fibers collecting the backscattered light at MHz pixel rates. Current 1-mm diameter catheterscopes generate 500-line images at maximum fields of view of 100 degrees and spatial resolutions of <20 microns with image zooming. Shaft length of four meters have been fabricated with flexibility of <10 mm bending radius to image previously inaccessible regions of the body.
Pressure monitoring predicts pulmonary vein occlusion in cryoballoon ablation.
Sunaga, Akihiro; Masuda, Masaharu; Asai, Mitsutoshi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Matsuda, Yasuhiro; Okuno, Syota; Mano, Toshiaki
2018-04-10
Pulmonary venography is routinely used to confirm pulmonary vein (PV) occlusion during cryoballoon ablation. However, this technique is significantly limited by the risks associated with contrast media, such as renal injury and contrast allergy. We hypothesized that PV occlusion can be predicted by elevation of the balloon catheter tip pressure, avoiding the need for contrast media. Forty-eight consecutive patients with paroxysmal atrial fibrillation who underwent PV isolation with the cryoballoon technique were enrolled. The balloon catheter tip pressure was measured in each PV before and after balloon inflation. We analyzed 200 applications of cryoballoon ablation in 185 PVs (excluding 3 common PVs and 1 extremely small right inferior PV) of 48 patients (age, 70 ± 11 years; male, n = 28; mean left atrial diameter, 38 ± 6 mm). Compared with patients with unsuccessful occlusion, patients with successful occlusion demonstrated a larger change in pressure after balloon inflation (6 ± 8 vs. 2 ± 4 mmHg, P < 0.001), a lower minimum temperature (- 49 ± 6 vs. - 40 ± 8 °C, P < 0.001), and a higher PV isolation rate (97 vs. 64%, P < 0.001). The best cutoff value of a change in pressure for predicting PV occlusion was 4.5 mmHg, with a sensitivity of 67%, specificity of 83%, and predictive accuracy of 72%. Pressure monitoring is helpful to confirm PV occlusion during cryoballoon ablation.
Confocal microlaparoscope for imaging the fallopian tube
NASA Astrophysics Data System (ADS)
Wu, Tzu-Yu; Schafer, Rachel; Rouse, Andrew R.; Gmitro, Arthur F.
2012-02-01
Recent evidence suggests that epithelial ovarian cancer may originate in the fimbriated end of the fallopian tube1. Unlike many other cancers, poor access to the ovary and fallopian tubes has limited the ability to study the progression of this deadly disease and to diagnosis it during the early stage when it is most amenable to therapy. We have previously reported on a rigid confocal microlaparoscope system that is currently undergoing a clinical trial to image the epithelial surface of the ovary2. In order to gain in vivo access to the fallopian tubes we have developed a new confocal microlaparoscope with an articulating distal tip. The new instrument builds upon the technology developed for the existing confocal microlaparoscope. It has an ergonomic handle fabricated by a rapid prototyping printer. While maintaining compatibility with a 5 mm trocar, the articulating distal tip of the instrument consists of a 2.2 mm diameter bare fiber bundle catheter with automated dye delivery for fluorescence imaging. This small and flexible catheter design should enable the confocal microlaparoscope to image early stage ovarian cancer arising inside the fallopian tube. Early ex vivo mages of human fallopian tube and in vivo imaging results from recent open surgeries using the rigid confocal microlaparoscope system are presented. Ex vivo images from animal models using the new articulating bare fiber system are also presented. These high quality images collected by the new flexible system are similar in quality to those obtained from the epithelial surface of ovaries with the rigid clinical confocal microlaparoscope.
Zaidi, K U; Shah, F; Parmar, R; Thawani, V
2018-06-01
Candida albicans is the most prevalent fungal pathogen in humans. It is the causative agent and most associated with serious fungal infection, accounting for more than 90% of cases. It is a most common cause of deep mycoses and vulvovaginal candidiasis. In the present study we found that methanolic extract of O. sanctum in combination of fluconazole shows higher zone of inhibition and lesser MIC values as compared to methanolic extract of leaves of O. sanctum or fluconazole when used alone. Synergistic antimicrobial activity was found when methanolic extract of leaves of O. sanctum was used in combination with fluconazole against C. albicans azole resistance strains isolated from catheter tip (CT) and high vaginal swab (HVS) (FIC≤0.5). Partial synergistic activity was observed against urine (U). Methanolic extract of stem of O. sanctum in combination with fluconazole gave indifferent antifungal results (FIC=1.0-4.0). Benzene extract of the leaf and stem of O. sanctum in combination with fluconazole showed indifferent antifungal results (FIC=1.0-4.0). Aqueous extract of leaves of O. sanctum in combination with fluconazole showed partial synergistic antimicrobial activity against catheter tip (CT) and high vaginal swab (HVS) and urine (U) (FIC=0.5-1.0). In the present study we evaluate the synergism of C. albicans against azole resistant clinical isolates. This study indicates clear evidence supporting the traditional use of O. sanctum in treating Candida infectious diseases. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Calcified lesion modeling for excimer laser ablation
NASA Astrophysics Data System (ADS)
Scott, Holly A.; Archuleta, Andrew; Splinter, Robert
2009-06-01
Objective: Develop a representative calcium target model to evaluate penetration of calcified plaque lesions during atherectomy procedures using 308 nm Excimer laser ablation. Materials and Methods: An in-vitro model representing human calcified plaque was analyzed using Plaster-of-Paris and cement based composite materials as well as a fibrinogen model. The materials were tested for mechanical consistency. The most likely candidate(s) resulting from initial mechanical and chemical screening was submitted for ablation testing. The penetration rate of specific multi-fiber catheter designs and a single fiber probe was obtained and compared to that in human cadaver calcified plaque. The effects of lasing parameters and catheter tip design on penetration speed in a representative calcified model were verified against the results in human cadaver specimens. Results: In Plaster of Paris, the best penetration was obtained using the single fiber tip configuration operating at 100 Fluence, 120 Hz. Calcified human lesions are twice as hard, twice as elastic as and much more complex than Plaster of Paris. Penetration of human calcified specimens was highly inconsistent and varied significantly from specimen to specimen and within individual specimens. Conclusions: Although Plaster of Paris demonstrated predictable increases in penetration with higher energy density and repetition rate, it can not be considered a totally representative laser ablation model for calcified lesions. This is in part due to the more heterogeneous nature and higher density composition of cadaver intravascular human calcified occlusions. Further testing will require a more representative model of human calcified lesions.
Kawai, Eichiro; Yaoita, Hisao; Ichinoi, Natsuko; Sakamoto, Osamu; Kure, Shigeo
2017-01-01
Kocuria kristinae is a catalase-positive, coagulase-negative, Gram-positive coccus found in the environment and in normal skin and mucosa in humans; however, it is rarely isolated from clinical specimens and is considered a nonpathogenic bacterium. We describe a case of catheter-related bacteremia due to K. kristinae in a young adult with propionic acidemia undergoing periodic hemodialysis. The patient had a central venous catheter implanted for total parenteral nutrition approximately 6 months prior to the onset of symptoms because of repeated acute pancreatitis. K. kristinae was isolated from two sets of blood cultures collected from the catheter. Vancomycin followed by cefazolin for 16 days and 5-day ethanol lock therapy successfully eradicated the K. kristinae bacteremia. Although human infections with this organism appear to be rare and are sometimes considered to result from contamination, physicians should not underestimate its significance when it is isolated in clinical specimens. PMID:28194286
Kimura, Masato; Kawai, Eichiro; Yaoita, Hisao; Ichinoi, Natsuko; Sakamoto, Osamu; Kure, Shigeo
2017-01-01
Kocuria kristinae is a catalase-positive, coagulase-negative, Gram-positive coccus found in the environment and in normal skin and mucosa in humans; however, it is rarely isolated from clinical specimens and is considered a nonpathogenic bacterium. We describe a case of catheter-related bacteremia due to K. kristinae in a young adult with propionic acidemia undergoing periodic hemodialysis. The patient had a central venous catheter implanted for total parenteral nutrition approximately 6 months prior to the onset of symptoms because of repeated acute pancreatitis. K. kristinae was isolated from two sets of blood cultures collected from the catheter. Vancomycin followed by cefazolin for 16 days and 5-day ethanol lock therapy successfully eradicated the K. kristinae bacteremia. Although human infections with this organism appear to be rare and are sometimes considered to result from contamination, physicians should not underestimate its significance when it is isolated in clinical specimens.
Air embolism after central venous catheterization.
Kashuk, J L; Penn, I
1984-09-01
Air embolism--the most dangerous complication of central venous catheterization--may occur in several ways. The most frequent is from disconnection of the catheter from the related intravenous tubing. An embolism may present with a sucking sound, tachypnea, air hunger, wheezing, hypotension and a "mill wheel" murmur. A later manifestation is severe pulmonary edema. In a review of 24 patients, the mortality was 50 per cent. Among the survivors, five (42 per cent) had neurologic damage. Immediate treatment includes placing the patient in the left lateral and Trendelenberg positions, administration of oxygen and aspiration of air from the heart. Cardiac massage and emergency cardiopulmonary bypass may be necessary. Most instances can be prevented by inserting the cannula with the patient in the Trendelenberg position, occluding the cannula hub except briefly while the catheter is inserted, fixation of the catheter hub to its connections and occlusive dressing over the track after removal of the catheter.
A novel four-wire-driven robotic catheter for radio-frequency ablation treatment.
Yoshimitsu, Kitaro; Kato, Takahisa; Song, Sang-Eun; Hata, Nobuhiko
2014-09-01
Robotic catheters have been proposed to increase the efficacy and safety of the radio-frequency ablation treatment. The robotized motion of current robotic catheters mimics the motion of manual ones-namely, deflection in one direction and rotation around the catheter. With the expectation that the higher dexterity may achieve further efficacy and safety of the robotically driven treatment, we prototyped a four-wire-driven robotic catheter with the ability to deflect in two- degree-of-freedom motions in addition to rotation. A novel quad-directional structure with two wires was designed and developed to attain yaw and pitch motion in the robotic catheter. We performed a mechanical evaluation of the bendability and maneuverability of the robotic catheter and compared it with current manual catheters. We found that the four-wire-driven robotic catheter can achieve a pitching angle of 184.7[Formula: see text] at a pulling distance of wire for 11 mm, while the yawing angle was 170.4[Formula: see text] at 11 mm. The robotic catheter could attain the simultaneous two- degree-of-freedom motions in a simulated cardiac chamber. The results indicate that the four-wire-driven robotic catheter may offer physicians the opportunity to intuitively control a catheter and smoothly approach the focus position that they aim to ablate.
Videolaparoscopic Catheter Placement Reduces Contraindications to Peritoneal Dialysis
Santarelli, Stefano; Zeiler, Matthias; Monteburini, Tania; Agostinelli, Rosa Maria; Marinelli, Rita; Degano, Giorgio; Ceraudo, Emilio
2013-01-01
♦ Background: Videolaparoscopy is considered the reference method for peritoneal catheter placement in patients with previous abdominal surgery. The placement procedure is usually performed with at least two access sites: one for the catheter and the second for the laparoscope. Here, we describe a new one-port laparoscopic procedure that uses only one abdominal access site in patients not eligible for laparotomic catheter placement. ♦ Method: We carried out one-port laparoscopic placement in 21 patients presenting contraindications to blind surgical procedures because of prior abdominal surgery. This technique consists in the creation of a single mini-laparotomy access through which laparoscopic procedures and placement are performed. The catheter, rectified by an introducer, is inserted inside the port. Subsequently, the port is removed, leaving the catheter in pelvic position. The port is reintroduced laterally to the catheter, confirming or correcting its position. Laparotomic placement was performed in a contemporary group of 32 patients without contraindications to blind placement. Complications and long-term catheter outcome in the two groups were evaluated. ♦ Results: Additional interventions during placement were necessary in 12 patients of the laparoscopy group compared with 5 patients of the laparotomy group (p = 0.002). Laparoscopy documented adhesions in 13 patients, with need for adhesiolysis in 6 patients. Each group had 1 intraoperative complication: leakage in the laparoscopy group, and intestinal perforation in the laparotomy group. During the 2-year follow-up period, laparoscopic revisions had to be performed in 6 patients of the laparoscopy group and in 5 patients of the laparotomy group (p = 0.26). The 1-year catheter survival was similar in both groups. Laparoscopy increased by 40% the number of patients eligible to receive peritoneal dialysis. ♦ Conclusions: Videolaparoscopy placement in patients not eligible for blind surgical procedures seems to be equivalent to laparotomic placement with regard to complications and long-term catheter outcome. The number of patients able to receive peritoneal dialysis is substantially increased. PMID:23209040
Ruggeri, Andrea; Enseñat, Joaquim; Prats-Galino, Alberto; Lopez-Rueda, Antonio; Berenguer, Joan; Cappelletti, Martina; De Notaris, Matteo; d'Avella, Elena
2017-03-01
OBJECTIVE Neurosurgical management of many vascular and neoplastic lesions necessitates control of the internal carotid artery (ICA). The aim of this study was to investigate the feasibility of achieving control of the ICA through the endoscopic endonasal approach by temporary occlusion with a Fogarty balloon catheter. METHODS Ten endoscopic endonasal paraseptal approaches were performed on cadaveric specimens. A Fogarty balloon catheter was inserted through a sellar bony opening and pushed laterally and posteriorly extraarterially along the paraclival carotid artery. The balloon was then inflated, thus achieving temporary occlusion of the vessel. The position of the catheter was confirmed with CT scans, and occlusion of the ICA was demonstrated with angiography. The technique was performed in 2 surgical cases of pituitary macroadenoma with cavernous sinus invasion. RESULTS Positioning the Fogarty balloon catheter at the level of the paraclival ICA was achieved in all cadaveric dissections and surgical cases through a minimally invasive, quick, and safe approach. Inflation of the Fogarty balloon caused interruption of blood flow in 100% of cases. CONCLUSIONS Temporary occlusion of the paraclival ICA performed through the endoscopic endonasal route with the aid of a Fogarty balloon catheter may be another maneuver for dealing with intraoperative ICA control. Further clinical studies are required to prove the efficacy of this method.
Krause, R.; Auner, H. W.; Gorkiewicz, G.; Wölfler, A.; Daxboeck, F.; Linkesch, W.; Krejs, G. J.; Wenisch, C.; Reisinger, E. C.
2004-01-01
For febrile neutropenic patients who received hematopoietic stem cell transplantation, the Gram stain-acridine orange leukocyte cytospin (AOLC) test and the differential-time-to-positivity method (DTP) were performed. As a diagnostic tool for catheter-related bloodstream infections in these patients, the Gram stain-AOLC test has a lower sensitivity than does the DTP method but acceptable positive and negative predictive values. PMID:15472355
Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poulin, Eric; Fekete, Charles-Antoine Collins; Beaulieu, Luc
2013-11-15
Purpose: An innovative, simple, and fast method to optimize the number and position of catheters is presented for prostate and breast high dose rate (HDR) brachytherapy, both for arbitrary templates or template-free implants (such as robotic templates).Methods: Eight clinical cases were chosen randomly from a bank of patients, previously treated in our clinic to test our method. The 2D Centroidal Voronoi Tessellations (CVT) algorithm was adapted to distribute catheters uniformly in space, within the maximum external contour of the planning target volume. The catheters optimization procedure includes the inverse planning simulated annealing algorithm (IPSA). Complete treatment plans can then bemore » generated from the algorithm for different number of catheters. The best plan is chosen from different dosimetry criteria and will automatically provide the number of catheters and their positions. After the CVT algorithm parameters were optimized for speed and dosimetric results, it was validated against prostate clinical cases, using clinically relevant dose parameters. The robustness to implantation error was also evaluated. Finally, the efficiency of the method was tested in breast interstitial HDR brachytherapy cases.Results: The effect of the number and locations of the catheters on prostate cancer patients was studied. Treatment plans with a better or equivalent dose distributions could be obtained with fewer catheters. A better or equal prostate V100 was obtained down to 12 catheters. Plans with nine or less catheters would not be clinically acceptable in terms of prostate V100 and D90. Implantation errors up to 3 mm were acceptable since no statistical difference was found when compared to 0 mm error (p > 0.05). No significant difference in dosimetric indices was observed for the different combination of parameters within the CVT algorithm. A linear relation was found between the number of random points and the optimization time of the CVT algorithm. Because the computation time decrease with the number of points and that no effects were observed on the dosimetric indices when varying the number of sampling points and the number of iterations, they were respectively fixed to 2500 and to 100. The computation time to obtain ten complete treatments plans ranging from 9 to 18 catheters, with the corresponding dosimetric indices, was 90 s. However, 93% of the computation time is used by a research version of IPSA. For the breast, on average, the Radiation Therapy Oncology Group recommendations would be satisfied down to 12 catheters. Plans with nine or less catheters would not be clinically acceptable in terms of V100, dose homogeneity index, and D90.Conclusions: The authors have devised a simple, fast and efficient method to optimize the number and position of catheters in interstitial HDR brachytherapy. The method was shown to be robust for both prostate and breast HDR brachytherapy. More importantly, the computation time of the algorithm is acceptable for clinical use. Ultimately, this catheter optimization algorithm could be coupled with a 3D ultrasound system to allow real-time guidance and planning in HDR brachytherapy.« less
Bacteriuria and antibiotic resistance in catheter urine specimens following radical prostatectomy.
Banks, Jessica A; McGuire, Barry B; Loeb, Stacy; Shrestha, Sanjina; Helfand, Brian T; Catalona, William J
2013-10-01
There are increasing reports of infectious complications following prostate biopsy due to fluoroquinolone resistance. To determine infectious complications at catheter removal following radical prostatectomy (RP), another setting in daily urological practice where fluoroquinolone prophylaxis is frequently used. We prospectively examined urine culture results collected from 334 RP patients immediately prior to catheter removal. Patients received prophylactic antibiotics 1 day before, the day of, and for 5 days after catheter removal. Culture results were reviewed for bacterial species and antimicrobial susceptibilities. Patients with positive urine cultures resistant to the prophylactic antibiotic were switched to culture-specific antibiotic therapy and underwent follow-up culture. The frequency of urinary tract infection (UTI), complications, additional antibiotic therapy, and repeat urine cultures was determined within 60 days. Of the 334 patients identified, 203 (61%) had cultures with no bacterial growth, and 48 (14%) had colony counts of <1,000 bacteria or Candida albicans and received no further antibiotics. The remaining 83 (25%) had positive culture results, of which 7% were resistant to ciprofloxacin. Twenty-four bacterial species were identified, with Pseudomonas aeruginosa (5%) Escherichia coli (4%), and Staphylococcus epidermidis (3%) being the most frequent. Only two (0.6%) men developed clinical symptoms consistent with UTI (i.e., suprapubic pain, fever) prior to catheter removal, and no serious complications occurred. A substantial proportion of RP patients have positive urine cultures at the time of catheter removal, despite the administration of prophylactic fluoroquinolone antibiotics. Potentially virulent organisms are commonly cultured, and ciprofloxacin resistance is frequent. However, outcomes are favorable when culture-specific oral antibiotic therapy is initiated. Copyright © 2013 Elsevier Inc. All rights reserved.
Asano, K; Masui, Y; Masuda, K; Fujinaga, T
2002-01-01
To evaluate the feasibility of noninvasive estimation of cardiac systolic function using transthoracic continuous-wave Doppler echocardiography in dogs with mitral regurgitation. Seven mongrel dogs with experimental mitral regurgitation were used. Left ventriculography and measurement of pulmonary capillary wedge pressure were performed under inhalational anaesthesia. A micromanometer-tipped catheter was placed into the left ventricle and transthoracic echocardiography was carried out. The peak rate of left ventricular pressure rise (peak dP/dt) was derived simultaneously by continuous-wave Doppler and manometer measurements. The Doppler-derived dP/dt was compared with the catheter-measured peak dP/dt in the dogs. Classification of the severity of mitral regurgitation in the dogs was as follows: 1+, 2 dogs; 2+, 1 dog; 3+, 2 dogs; 4+, 1 dog; and not examined, 1 dog. We were able to derive dP/dt from the transthoracic continuous-wave Doppler echocardiography in all dogs. Doppler-derived dP/dt had a significant correlation with the catheter-measured peak dP/dt (r = 0.90, P < 0.0001). It was demonstrated that transthoracic continuous-wave Doppler echocardiography is a feasible method of noninvasive estimation of cardiac systolic function in dogs with experimental mitral regurgitation and may have clinical usefulness in canine patients with spontaneous mitral regurgitation.
Vaidyanathan, Subramanian; Soni, Bakul; Singh, Gurpreet; Hughes, Peter; Oo, Tun
2011-01-01
When urethral catheterisation is difficult or impossible in spinal cord injury patients, flexible cystoscopy and urethral catheterisation over a guide wire can be performed on the bedside, thus obviating the need for emergency suprapubic cystostomy. Spinal cord injury patients, who undergo flexible cystoscopy and urethral catheterisation over a guide wire, may develop potentially serious complications. (1) Persons with lesion above T-6 are susceptible to develop autonomic dysreflexia during cystoscopy and urethral catheterisation over a guide wire; nifedipine 5-10 milligrams may be administered sublingually just prior to the procedure to prevent autonomic dysreflexia. (2) Spinal cord injury patients are at increased risk for getting urine infections as compared to able-bodied individuals. Therefore, antibiotics should be given to patients who get haematuria or urethral bleeding following urethral catheterisation over a guide wire. (3) Some spinal cord injury patients may have a small capacity bladder; in these patients, the guide wire, which is introduced into the urinary bladder, may fold upon itself with the tip of guide wire entering the urethra. If this complication is not recognised and a catheter is inserted over the guide wire, the Foley catheter will then be misplaced in urethra despite using cystoscopy and guide wire.
Vaidyanathan, Subramanian; Soni, Bakul; Singh, Gurpreet; Hughes, Peter; Oo, Tun
2011-01-01
When urethral catheterisation is difficult or impossible in spinal cord injury patients, flexible cystoscopy and urethral catheterisation over a guide wire can be performed on the bedside, thus obviating the need for emergency suprapubic cystostomy. Spinal cord injury patients, who undergo flexible cystoscopy and urethral catheterisation over a guide wire, may develop potentially serious complications. (1) Persons with lesion above T-6 are susceptible to develop autonomic dysreflexia during cystoscopy and urethral catheterisation over a guide wire; nifedipine 5–10 milligrams may be administered sublingually just prior to the procedure to prevent autonomic dysreflexia. (2) Spinal cord injury patients are at increased risk for getting urine infections as compared to able-bodied individuals. Therefore, antibiotics should be given to patients who get haematuria or urethral bleeding following urethral catheterisation over a guide wire. (3) Some spinal cord injury patients may have a small capacity bladder; in these patients, the guide wire, which is introduced into the urinary bladder, may fold upon itself with the tip of guide wire entering the urethra. If this complication is not recognised and a catheter is inserted over the guide wire, the Foley catheter will then be misplaced in urethra despite using cystoscopy and guide wire. PMID:22110492
Successful surgical treatment of left atrioesophageal fistula following atrial ablation.
Takahashi, Toru; Mohara, Jun; Ogawa, Hiroomi; Igarashi, Takamichi; Motegi, Yoko
2018-01-23
A 69-year-old male had catheter-based ablation for atrial fibrillation. He was admitted with high fever and had neurological disorder; he was diagnosed with atrioesophageal fistula by CT scan. Intraoperative findings showed that the fistula existed adjacent to the left lower pulmonary vein with a vegetation. The esophageal fistula was repaired, and the left atrial fistula was closed. A nasogastric tube tip was placed in the esophagus for decompression and advanced into the stomach for nutritional support. After vomiting, the patient showed loss of consciousness and left hemiplegia. CT scan revealed a micro-air embolism to the brain. The nasogastric tube tip was pulled back into the esophagus. Gastrointestinal fiberscopy showed a pinhole at the fistula, and a percutaneous endoscopic gastrostomy was made. After conservative treatment, the esophageal fistula was closed and mediastinitis was improved. He was discharged with a little neurological deficit.
Gray, Dorinne; Nussle, Richard; Cruz, Abner; Kane, Gail; Toomey, Michael; Bay, Curtis; Ostovar, Gholamabbas Amin
2016-01-01
Preventing catheter-associated urinary tract infections is in the forefront of health care quality. However, nurse and physician engagement is a common barrier in infection prevention efforts. After implementation of a multidisciplinary catheter-associated urinary tract infection (CAUTI) prevention campaign, we studied the impact of our campaign and showed its association with reducing the CAUTI rate and catheter utilization and the positive effect on health care workers' engagement and perspectives. CAUTI prevention campaigns can lead to lower infection rates and change health care workers' perspective. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Infection and hemodialysis access: an updated review.
Gupta, Vineet; Yassin, Mohamed H
2013-06-01
The incidence of end-stage renal disease (ESRD) has almost doubled over past 2 decades. Despite decreasing overall hospital admission rates for ESRD population, the rate of infection-related hospitalizations has steadily increased. Infection remains the second most common cause of mortality in this patient population. Specifically, in the hemodialysis (HD) patients, the vascular access related infections are the most common identifiable source of infection. This concise review provides an update on the bacteremia related to vascular access primarily the catheters (Catheter Related Blood Stream Infection- CRBSI) in HD patients emphasizing on the determinants ranging from the epidemiology to pathogenesis, risk factors, cost implications and prevention. Staphylococcus aureus, coagulase negative Staphylococci, and Enterococci are the most common causative microorganisms implicated in CRBSI. The pathogenesis of CRBSI includes organism entry into the blood stream followed by adherence to catheter, colonization and biofilm formation. Vascular access type, catheter position, and prior bacteremic episodes are strongly associated with blood stream infection. Preventive measures should be multidisciplinary in nature and should include avoidance of central venous catheters, best practices for catheter care, surveillance, antimicrobial catheter lock solutions, and use of antibiotic impregnated catheters.
Li, Yi-gang; Grönefeld, Gerian; Israel, Carsten; Lu, Shang-biao; Wang, Qun-shan; Hohnloser, Stefan H
2006-12-20
Atrial tachycardia or flutter is common in patients after orthotopic heart transplantation. Radiofrequency catheter ablation to treat this arrhythmia has not been well defined in this setting. This study was conducted to assess the incidence of various symptomatic atrial arrhythmias and the efficacy and safety of radiofrequency catheter ablation in these patients. Electrophysiological study and catheter ablation were performed in patients with symptomatic tachyarrhythmia. One Halo catheter with 20 poles was positioned around the tricuspid annulus of the donor right atrium, or positioned around the surgical anastomosis when it is necessary. Three quadripolar electrode catheters were inserted via the right or left femoral vein and positioned in the recipient atrium, the bundle of His position, the coronary sinus. Programmed atrial stimulation and burst pacing were performed to prove electrical conduction between the recipient and the donor atria and to induce atrial arrhythmias. Out of 55 consecutive heart transplantation patients, 6 males [(58 +/- 12) years] developed symptomatic tachycardias at a mean of (5 +/- 4) years after heart transplantation. Electrical propagation through the suture line between the recipient and the donor atrium was demonstrated during atrial flutter or during recipient atrium and donor atrium pacing in 2 patients. By mapping around the suture line, the earliest fragmented electrogram of donor atrium was assessed. This electrical connection was successfully ablated in the anterior lateral atrium in both patients. There was no electrical propagation through the suture line in the other 4 patients. Two had typical atrial flutter in the donor atrium which was successfully ablated by completing a linear ablation between the tricuspid annulus and the inferior vena cava. Two patients had atrial tachycardia which was ablated in the anterior septal and lateral donor atrium. There were no procedure-related complications. Patients were free of recurrent atrial tachyarrhythmias after a follow-up of (8 +/- 7) months. Four electrophysiological mechanisms have been found to contribute to the occurrence of symptomatic supraventricular arrhythmias following heart transplantation. Radiofrequency catheter ablation in patients with atrial flutter/tachycardia is feasible and safe after heart transplantation.
[Magnetic navigation for ablation of cardiac arrhythmias].
Chen, Jian; Hoff, Per Ivar; Solheim, Eivind; Schuster, Peter; Off, Morten Kristian; Ohm, Ole-Jørgen
2010-08-12
The first use of magnetic navigation for radiofrequency ablation of supraventricular tachycardias, was published in 2004. Subsequently, the method has been used for treatment of most types of tachyarrhythmias. This paper provides an overview of the method, with special emphasis on usefulness of a new remote-controlled magnetic navigation system. The paper is based on our own scientific experience and literature identified through a non-systematic search in PubMed. The magnetic navigation system consists of two external electromagnets (to be placed on opposite sides of the patient), which guide an ablation catheter (with a small magnet at the tip of the catheter) to the target area in the heart. The accuracy of this procedure is higher than that with manual navigation. Personnel can be quickly trained to use remote magnetic navigation, but the procedure itself is time-consuming, particularly for patients with atrial fibrillation. The major advantage is a considerably lower radiation burden to both patient and operator, in some studies more than 50 %, and a corresponding reduction in physical strain on the operator. The incidence of procedure-related complications seems to be lower than that observed with use of manually operated ablation catheters. Work is ongoing to improve magnetic ablation catheters and methods that can simplify mapping procedures and improve efficacy of arrhythmia ablation. The basic cost for installing a complete magnetic navigation laboratory may be three times that of a conventional electrophysiological laboratory. The new magnetic navigation system has proved to be applicable during ablation for a variety of tachyarrhythmias, but is still under development.
Plowden, Torie C; Hill, Micah J; Miles, Shana M; Hoyt, Benjamin; Yauger, Belinda; Segars, James H; Csokmay, John M; Chason, Rebecca J
2017-05-01
The technique used for embryo transfer (ET) can affect implantation. Prior research that evaluated the effect of postprocedural blood of the transfer catheter tip have yielded mixed results, and it is unclear whether this is actually a marker of difficulty of the transfer. Our objective was to estimate the effect of blood at the time of ET and the difficulty of ET on live birth rates (LBR). This retrospective cohort study utilized generalized estimating equations (GEEs) with nesting for repeated cycles for all analyses. Univariate modeling was performed and a final multivariate (adjusted) GEE model accounted for all significant confounders. Embryo transfers were subjectively graded (easy, medium, or hard) by a physician at the time of transfer. The presence of blood at ET was associated with more difficult ETs, retained embryos, and presence of mucous in the catheter. In the univariate analysis, ET with blood was not associated with live birth, while the degree of difficulty for ET had a negative impact on LBR. In the final multivariate GEE model, which accounts for repeated cycles from a patient, the only factors associated with an increased LBR were the degree of difficulty of the ET, female age, and blastocyst transfer. After controlling for confounding variables, the presence of blood in the transfer catheter was not associated with the likelihood of pregnancy and thus was not an independent predictor of cycle outcome. This indicates that the difficulty of the transfer itself was a strong negative predictor of pregnancy.
An Effective Technique for Enhancing an Intrauterine Catheter Fetal Electrocardiogram
NASA Astrophysics Data System (ADS)
Horner, Steven L.; Holls, William M.
2003-12-01
Physician can obtain fetal heart rate, electrophysiological information, and uterine contraction activity for determining fetal status from an intrauterine catheters electrocardiogram with the maternal electrocardiogram canceled. In addition, the intrauterine catheter would allow physicians to acquire fetal status with one non-invasive to the fetus biosensor as compared to invasive to the fetus scalp electrode and intrauterine pressure catheter used currently. A real-time maternal electrocardiogram cancellation technique of the intrauterine catheters electrocardiogram will be discussed along with an analysis for the methods effectiveness with synthesized and clinical data. The positive results from an original detailed subjective and objective analysis of synthesized and clinical data clearly indicate that the maternal electrocardiogram cancellation method was found to be effective. The resulting intrauterine catheters electrocardiogram from effectively canceling the maternal electrocardiogram could be used for determining fetal heart rate, fetal electrocardiogram electrophysiological information, and uterine contraction activity.
Wilde, Mary H; McMahon, James M; Crean, Hugh F; Brasch, Judith
2017-09-01
To describe and explore relationships among catheter problems in long-term indwelling urinary catheter users, including excess healthcare use for treating catheter problems. Long-term urinary catheter users experience repeated problems with catheter-related urinary tract infection and blockage of the device, yet little has been reported of the patterns and relationships among relevant catheter variables. Secondary data analysis was conducted from a sample in a randomised clinical trial, using data from the entire sample of 202 persons over 12 months' participation. Descriptive statistics were used to characterise the sample over time. Zero-inflated negative binomial models were employed for logistic regressions to evaluate predictor variables of the presence/absence and frequencies of catheter-related urinary tract infection and blockage. Catheter-related urinary tract infection was marginally associated with catheter blockage. Problems reported at least once per person in the 12 months were as follows: catheter-related urinary tract infection 57%, blockage 34%, accidental dislodgment 28%, sediment 87%, leakage (bypassing) 67%, bladder spasms 59%, kinks/twists 42% and catheter pain 49%. Regression analysis demonstrated that bladder spasms were significantly related to catheter-related urinary tract infection and sediment amount, and catheter leakages were marginally significantly and positively related to catheter-related urinary tract infection. Frequencies of higher levels of sediment and catheter leakage were significantly associated with higher levels of blockage, and being female was associated with fewer blockages. Persons who need help with eating (more disabled) were also more likely to have blockages. Catheter-related urinary tract infection and blockage appear to be related and both are associated with additional healthcare expenditures. More research is needed to better understand how to prevent adverse catheter outcomes and patterns of problems in subgroups. Nurses can develop care management strategies to identify catheter blockage prior to its occurrence by tracking the amount of sediment and frequency of leakage. Bladder spasms could be an early warning of catheter-related urinary tract infection. © 2016 John Wiley & Sons Ltd.
Rafii-Tari, Hedyeh; Liu, Jindong; Payne, Christopher J; Bicknell, Colin; Yang, Guang-Zhong
2014-01-01
Despite increased use of remote-controlled steerable catheter navigation systems for endovascular intervention, most current designs are based on master configurations which tend to alter natural operator tool interactions. This introduces problems to both ergonomics and shared human-robot control. This paper proposes a novel cooperative robotic catheterization system based on learning-from-demonstration. By encoding the higher-level structure of a catheterization task as a sequence of primitive motions, we demonstrate how to achieve prospective learning for complex tasks whilst incorporating subject-specific variations. A hierarchical Hidden Markov Model is used to model each movement primitive as well as their sequential relationship. This model is applied to generation of motion sequences, recognition of operator input, and prediction of future movements for the robot. The framework is validated by comparing catheter tip motions against the manual approach, showing significant improvements in the quality of catheterization. The results motivate the design of collaborative robotic systems that are intuitive to use, while reducing the cognitive workload of the operator.
Leiterer, Christian; Deckert-Gaudig, Tanja; Singh, Prabha; Wirth, Janina; Deckert, Volker; Fritzsche, Wolfgang
2015-05-01
Tip-enhanced Raman spectroscopy, a combination of Raman spectroscopy and scanning probe microscopy, is a powerful technique to detect the vibrational fingerprint of molecules at the nanometer scale. A metal nanoparticle at the apex of an atomic force microscope tip leads to a large enhancement of the electromagnetic field when illuminated with an appropriate wavelength, resulting in an increased Raman signal. A controlled positioning of individual nanoparticles at the tip would improve the reproducibility of the probes and is quite demanding due to usually serial and labor-intensive approaches. In contrast to commonly used submicron manipulation techniques, dielectrophoresis allows a parallel and scalable production, and provides a novel approach toward reproducible and at the same time affordable tip-enhanced Raman spectroscopy tips. We demonstrate the successful positioning of an individual plasmonic nanoparticle on a commercial atomic force microscope tip by dielectrophoresis followed by experimental proof of the Raman signal enhancing capabilities of such tips. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Voided Midstream Urine Culture and Acute Cystitis in Premenopausal Women
Hooton, Thomas M; Roberts, Pacita L.; Cox, Marsha E.; Stapleton, Ann E.
2014-01-01
BACKGROUND The cause of acute uncomplicated cystitis is determined on the basis of cultures of voided midstream urine, but few data guide the interpretation of such results, especially when gram-positive bacteria grow. METHODS Women from 18 to 49 years of age with symptoms of cystitis provided specimens of midstream urine, after which we collected urine by means of a urethral catheter for culture (catheter urine). We compared microbial species and colony counts in the paired specimens. The primary outcome was a comparison of positive predictive values and negative predictive values of organisms grown in midstream urine, with the presence or absence of the organism in catheter urine used as the reference. RESULTS The analysis of 236 episodes of cystitis in 226 women yielded 202 paired specimens of midstream urine and catheter urine that could be evaluated. Cultures were positive for uropathogens in 142 catheter specimens (70%), 4 of which had more than one uropathogen, and in 157 midstream specimens (78%). The presence of Escherichia coli in midstream urine was highly predictive of bladder bacteriuria even at very low counts, with a positive predictive value of 102 colony-forming units (CFU) per milliliter of 93% (Spearman’s r = 0.944). In contrast, in midstream urine, enterococci (in 10% of cultures) and group B streptococci (in 12% of cultures) were not predictive of bladder bacteriuria at any colony count (Spearman’s r = 0.322 for enterococci and 0.272 for group B streptococci). Among 41 episodes in which enterococcus, group B streptococci, or both were found in midstream urine, E. coli grew from catheter urine cultures in 61%. CONCLUSIONS Cultures of voided midstream urine in healthy premenopausal women with acute uncomplicated cystitis accurately showed evidence of bladder E. coli but not of enterococci or group B streptococci, which are often isolated with E. coli but appear to rarely cause cystitis by themselves. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases.) PMID:24224622
Catheterized plasma X-ray source
Derzon, Mark S.; Robinson, Alex; Galambos, Paul C.
2017-06-20
A radiation generator useful for medical applications, among others, is provided. The radiation generator includes a catheter; a plasma discharge chamber situated within a terminal portion of the catheter, a cathode and an anode positioned within the plasma discharge chamber and separated by a gap, and a high-voltage transmission line extensive through the interior of the catheter and terminating on the cathode and anode so as to deliver, in operation, one or more voltage pulses across the gap.
2013-01-01
inferior venae cavae , pumped through a respiratory mem- brane, and returned into the right atrium . The insertion of these cathe- ters is...sheath and advanced through the superior vena cava and the right atrium into the inferior vena cava . Correct position was confirmed via fluoroscopy...these catheters, blood is drained from the superior and inferior venae cavae through two dedicated ports and is pumped through a respiratory
A novel mechanism of toxic injury to the Papez circuit from chemotherapy.
Kwan, Benjamin Yin Ming; Krings, Timo; Bernstein, Mark; Mandell, Daniel M
2015-04-01
Toxic effects of chemotherapy delivered via Ommaya reservoir include pericatheter necrosis and toxic leukoencephalopathy. Imaging evidence of toxicity is often asymptomatic, but can be clinically consequential. A young patient, treated for cerebrospinal fluid relapse of acute lymphoblastic leukemia with methotrexate and cytarabine via Ommaya reservoir, presented with acute deterioration of short-term memory. MRI demonstrated extra-ventricular Ommaya catheter position and typical methotrexate-induced changes in the deep white matter, but also signal alteration in the forniceal columns and mammillary bodies, components of the Papez circuit. This case presents a novel mechanism of chemotherapy-induced neurotoxicity associated with extra-ventricular Ommaya catheter position. Specifically, the clinical and imaging findings suggest that extra-ventricular Ommaya catheter position may lead to a direct methotrexate-induced toxicity to the Papez circuit. This provides further clinical evidence of the function of the circuit. The possibility that this patient received a supratherapeutic dose of methotrexate may explain why this presentation with profound memory impairment is not more common. However, this case also provides a potential explanation for patients who receive standard dose chemotherapy via extra-ventricular Ommaya catheter and develop milder memory loss. Copyright © 2014 Elsevier Ltd. All rights reserved.
Evaluation of dual-tip micromanometers during 21-day implantation in goats
NASA Technical Reports Server (NTRS)
Reister, C. A.; Koenig, S. C.; Schaub, J. D.; Ewert, D. L.; Swope, R. D.; Latham, R. D.; Fanton, J. W.; Convertino, V. A. (Principal Investigator)
1998-01-01
Investigative research efforts using a cardiovascular model required the determination of central circulatory haemodynamic and arterial system parameters for the evaluation of cardiovascular performance. These calculations required continuous beat-to-beat measurement of pressure within the four chambers of the heart and great vessels. Sensitivity and offset drift, longevity, and sources of error for eight 3F dual-tipped micromanometers were determined during 21 days of implantation in goats. Subjects were instrumented with pairs of chronically implanted fluid-filled access catheters in the left and right ventricles, through which dual-tipped (test) micromanometers were chronically inserted and single-tip (standard) micromanometers were acutely inserted. Acutely inserted sensors were calibrated daily and measured pressures were compared in vivo to the chronically inserted sensors. Comparison of the pre- and post-gain calibration of the chronically inserted sensors showed a mean sensitivity drift of 1.0 +/- 0.4% (99% confidence, n = 9 sensors) and mean offset drift of 5.0 +/- 1.5 mmHg (99% confidence, n = 9 sensors). Potential sources of error for these drifts were identified, and included measurement system inaccuracies, temperature drift, hydrostatic column gradients, and dynamic pressure changes. Based upon these findings, we determined that these micromanometers may be chronically inserted in high-pressure chambers for up to 17 days with an acceptable error, but should be limited to acute (hours) insertions in low-pressure applications.
Method for measuring the contour of a machined part
Bieg, L.F.
1995-05-30
A method is disclosed for measuring the contour of a machined part with a contour gage apparatus, having a probe assembly including a probe tip for providing a measure of linear displacement of the tip on the surface of the part. The contour gage apparatus may be moved into and out of position for measuring the part while the part is still carried on the machining apparatus. Relative positions between the part and the probe tip may be changed, and a scanning operation is performed on the machined part by sweeping the part with the probe tip, whereby data points representing linear positions of the probe tip at prescribed rotation intervals in the position changes between the part and the probe tip are recorded. The method further allows real-time adjustment of the apparatus machining the part, including real-time adjustment of the machining apparatus in response to wear of the tool that occurs during machining. 5 figs.
Method for measuring the contour of a machined part
Bieg, Lothar F.
1995-05-30
A method for measuring the contour of a machined part with a contour gage apparatus, having a probe assembly including a probe tip for providing a measure of linear displacement of the tip on the surface of the part. The contour gage apparatus may be moved into and out of position for measuring the part while the part is still carried on the machining apparatus. Relative positions between the part and the probe tip may be changed, and a scanning operation is performed on the machined part by sweeping the part with the probe tip, whereby data points representing linear positions of the probe tip at prescribed rotation intervals in the position changes between the part and the probe tip are recorded. The method further allows real-time adjustment of the apparatus machining the part, including real-time adjustment of the machining apparatus in response to wear of the tool that occurs during machining.
Cannula Tip With Integrated Volume Sensor for Rotary Blood Pump Control: Early-Stage Development.
Cysyk, Joshua; Newswanger, Ray; Popjes, Eric; Pae, Walter; Jhun, Choon-Sik; Izer, Jenelle; Weiss, William; Rosenberg, Gerson
2018-05-10
The lack of direct measurement of left ventricular unloading is a significant impediment to the development of an automatic speed control system for continuous-flow left ventricular assist devices (cf-LVADs). We have developed an inlet cannula tip for cf-LVADs with integrated electrodes for volume sensing based on conductance. Four platinum-iridium ring electrodes were installed into grooves on a cannula body constructed from polyetheretherketone (PEEK). A sinusoidal current excitation waveform (250 μA pk-pk, 50 kHz) was applied across one pair of electrodes, and the conductance-dependent voltage was sensed across the second pair of electrodes. The conductance catheter was tested in an acute ovine model (n = 3) in conjunction with the HeartMate II rotary blood pump to provide circulatory support and unload the ventricle. Echocardiography was used to measure ventricular size during pump support for verification for the conductance measurements. The conductance measurements correlated linearly with the echocardiography dimension measurements more than the full range of pump support from minimum support to suction. This cannula tip will enable the development of automatic control systems to optimize pump support based on a real-time measurement of ventricular size.
Filgueiras-Rama, David; Estrada, Alejandro; Shachar, Josh; Castrejón, Sergio; Doiny, David; Ortega, Marta; Gang, Eli; Merino, José L
2013-04-21
New remote navigation systems have been developed to improve current limitations of conventional manually guided catheter ablation in complex cardiac substrates such as left atrial flutter. This protocol describes all the clinical and invasive interventional steps performed during a human electrophysiological study and ablation to assess the accuracy, safety and real-time navigation of the Catheter Guidance, Control and Imaging (CGCI) system. Patients who underwent ablation of a right or left atrium flutter substrate were included. Specifically, data from three left atrial flutter and two counterclockwise right atrial flutter procedures are shown in this report. One representative left atrial flutter procedure is shown in the movie. This system is based on eight coil-core electromagnets, which generate a dynamic magnetic field focused on the heart. Remote navigation by rapid changes (msec) in the magnetic field magnitude and a very flexible magnetized catheter allow real-time closed-loop integration and accurate, stable positioning and ablation of the arrhythmogenic substrate.
Filgueiras-Rama, David; Estrada, Alejandro; Shachar, Josh; Castrejón, Sergio; Doiny, David; Ortega, Marta; Gang, Eli; Merino, José L.
2013-01-01
New remote navigation systems have been developed to improve current limitations of conventional manually guided catheter ablation in complex cardiac substrates such as left atrial flutter. This protocol describes all the clinical and invasive interventional steps performed during a human electrophysiological study and ablation to assess the accuracy, safety and real-time navigation of the Catheter Guidance, Control and Imaging (CGCI) system. Patients who underwent ablation of a right or left atrium flutter substrate were included. Specifically, data from three left atrial flutter and two counterclockwise right atrial flutter procedures are shown in this report. One representative left atrial flutter procedure is shown in the movie. This system is based on eight coil-core electromagnets, which generate a dynamic magnetic field focused on the heart. Remote navigation by rapid changes (msec) in the magnetic field magnitude and a very flexible magnetized catheter allow real-time closed-loop integration and accurate, stable positioning and ablation of the arrhythmogenic substrate. PMID:23628883
The role of robotic endovascular catheters in fenestrated stent grafting.
Riga, Celia V; Cheshire, Nicholas J W; Hamady, Mohamad S; Bicknell, Colin D
2010-04-01
Fenestrated stent grafting has allowed the treatment of complex thoraco-abdominal aneurysm disease via a totally endovascular approach, but the procedure can be technically challenging and time consuming. We investigated whether this procedure may be enhanced by remotely steerable robotic endovascular catheters. A four-vessel fenestrated stent graft partially deployed within a computed tomography (CT)-reconstructed pulsatile thoraco-abdominal aneurysm silicon model was used. Fifteen operators were recruited to participate in the study and divided into three groups, based on their endovascular experience: group A (n = 4, 100-200 endovascular procedures, group B (n = 5, 200-300), and group C (n = 6, >300). All operators were asked to cannulate the renal and visceral vessels under fluoroscopic guidance, using conventional and robotic techniques. Quantitative (catheterization times and wire/catheter tip movements) and qualitative metrics (procedure-specific-rating scale [IC3ST]), which grades operators on catheter use, instrumentation, successful cannulation/catheterization, and overall performance were compared. Median procedure time for cannulation of all four vessels was reduced using the robotic system (2.87 min, interquartile range [IQR; 2.20-3.90] versus 17.24 min [11.90-19.80]; P < .001) for each individual operator, regardless of the level of endovascular experience. The total number of wire/catheter movements taken to complete the task was also significantly reduced (38, IQR [29-57] versus 454 [283-687]; P < .001). There were significant differences in time and movement for cannulation of each individual vessel in the phantom. Robotic catheter operator radiation exposure was negligible as the robotic workstation is remote and away from the radiation source. Overall performance scores significantly improved using the robotic system, despite minimal operator exposure to this technology (IC3ST score 29/35, IQR [22.8-30.7] versus 19/35 [13-24.3]; P = .002). Each group of operators demonstrated an improvement in performance with robotic cannulation. For group A, median IC3ST score was 28/35, IQR (22-33) versus 15/35 (11-20); P = .04; for group B, 30/35 (27-31) versus 19/35 (18-24); P = .07; and for group C, 28.8/35 (28.5-29) versus 22/35 (16-24); P = .06. For groups B and C, these differences did not reach statistical significance. Robotic catheterization of target vessels during this procedure is feasible and minimizes radiation exposure for the operator. Steerable robotic catheters with intuitive control may overcome some of the limitations of standard catheter technology, enhance target vessel cannulation, reduce instrumentation, and improve overall performance scores.
Sztain, Jacklynn F; Khatibi, Bahareh; Monahan, Amanda M; Said, Engy T; Abramson, Wendy B; Gabriel, Rodney A; Finneran, John J; Bellars, Richard H; Nguyen, Patrick L; Ball, Scott T; Gonzales, Francis B; Ahmed, Sonya S; Donohue, Michael C; Padwal, Jennifer A; Ilfeld, Brian M
2018-07-01
A continuous adductor canal block provides analgesia after surgical procedures of the knee. Recent neuroanatomic descriptions of the thigh and knee led us to speculate that local anesthetic deposited in the distal thigh close to the adductor hiatus would provide superior analgesia compared to a more proximal catheter location. We therefore tested the hypothesis that during a continuous adductor canal nerve block, postoperative analgesia would be improved by placing the perineural catheter tip 2-3 cm cephalad to where the femoral artery descends posteriorly to the adductor hiatus (distal location) compared to a more proximal location at the midpoint between the anterior superior iliac spine and the superior border of the patella (proximal location). Preoperatively, subjects undergoing total knee arthroplasty received an ultrasound-guided perineural catheter inserted either in the proximal or distal location within the adductor canal in a randomized, subject-masked fashion. Subjects received a single injection of lidocaine 2% via the catheter preoperatively, followed by an infusion of ropivacaine 0.2% (8 mL/h basal, 4 mL bolus, 30 minutes lockout) for the study duration. After joint closure, the surgeon infiltrated the entire joint using 30 mL of ropivacaine (0.5%), ketorolac (30 mg), epinephrine (5 μg/mL), and tranexamic acid (2 g). The primary end point was the median level of pain as measured on a numeric rating scale (NRS) during the time period of 8:00 AM to 12:00 PM the day after surgery. For the primary end point, the NRS of subjects with a catheter inserted at the proximal location (n = 24) was a median (10th, 25th-75th, 90th quartiles) of 0.5 (0.0, 0.0-3.2, 5.0) vs 3.0 (0.0, 2.0-5.4, 7.8) for subjects with a catheter inserted in the distal location (n = 26; P = .011). Median and maximum NRSs were lower in the proximal group at all other time points, but these differences did not reach statistical significance. There were no clinically relevant or statistically significant differences between the treatment groups for any other secondary end point, including opioid consumption and ambulation distance. For continuous adductor canal blocks accompanied by intraoperative periarticular local anesthetic infiltration, analgesia the day after knee arthroplasty is improved with a catheter inserted at the level of the midpoint between the anterior superior iliac spine and the superior border of the patella compared with a more distal insertion closer to the adductor hiatus.
A Targeted Infection Prevention Intervention in Nursing Home Residents With Indwelling Devices
Mody, Lona; Krein, Sarah L.; Saint, Sanjay K.; Min, Lillian C.; Montoya, Ana; Lansing, Bonnie; McNamara, Sara E.; Symons, Kathleen; Fisch, Jay; Koo, Evonne; Rye, Ruth Anne; Galecki, Andrzej; Kabeto, Mohammed U.; Fitzgerald, James T.; Olmsted, Russell N.; Kauffman, Carol A.; Bradley, Suzanne F.
2015-01-01
IMPORTANCE Indwelling devices (eg, urinary catheters and feeding tubes) are often used in nursing homes (NHs). Inadequate care of residents with these devices contributes to high rates of multidrug-resistant organisms (MDROs) and device-related infections in NHs. OBJECTIVE To test whether a multimodal targeted infection program (TIP) reduces the prevalence of MDROs and incident device-related infections. DESIGN, SETTING, AND PARTICIPANTS Randomized clinical trial at 12 community-based NHs from May 2010 to April 2013. Participants were high-risk NH residents with urinary catheters, feeding tubes, or both. INTERVENTIONS Multimodal, including preemptive barrier precautions, active surveillance for MDROs and infections, and NH staff education. MAIN OUTCOMES AND MEASURES The primary outcome was the prevalence density rate of MDROs, defined as the total number of MDROs isolated per visit averaged over the duration of a resident's participation. Secondary outcomes included new MDRO acquisitions and new clinically defined device-associated infections. Data were analyzed using a mixed-effects multilevel Poisson regression model (primary outcome) and a Cox proportional hazards model (secondary outcome), adjusting for facility-level clustering and resident-level variables. RESULTS In total, 418 NH residents with indwelling devices were enrolled, with 34 174 device-days and 6557 anatomic sites sampled. Intervention NHs had a decrease in the overall MDRO prevalence density (rate ratio, 0.77; 95% CI, 0.62–0.94). The rate of new methicillin-resistant Staphylococcus aureus acquisitions was lower in the intervention group than in the control group (rate ratio, 0.78; 95% CI, 0.64–0.96). Hazard ratios for the first and all (including recurrent) clinically defined catheter-associated urinary tract infections were 0.54 (95% CI, 0.30–0.97) and 0.69 (95% CI, 0.49–0.99), respectively, in the intervention group and the control group. There were no reductions in new vancomycin-resistant enterococci or resistant gram-negative bacilli acquisitions or in new feeding tube–associated pneumonias or skin and soft-tissue infections. CONCLUSIONS AND RELEVANCE Our multimodal TIP intervention reduced the overall MDRO prevalence density, new methicillin-resistant S aureus acquisitions, and clinically defined catheter-associated urinary tract infection rates in high-risk NH residents with indwelling devices. Further studies are needed to evaluate the cost-effectiveness of this approach as well as its effects on the reduction of MDRO transmission to other residents, on the environment, and on referring hospitals. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT01062841 PMID:25775048
Peripherally inserted central catheters in the neonatal period.
Uygun, Ibrahim; Okur, Mehmet Hanifi; Otcu, Selcuk; Ozturk, Hayrettin
2011-10-01
Peripherally inserted central catheters (PICC) have been extensively used in neonates. However, insertion of these thinnest catheters is a very delicate procedure associated with a high failure rate. In our Neonatal Surgical Intensive Care Unit, we developed a very easy new PICC insertion and evaluated the neonates treated with PICCs which were inserted by using our technique as well as catheter features such as success rate, number of insertion attempts, reason for removal and complications. Information was retrospectively collected on all 40 PICCs inserted at Kutahya Evliya Celebi Goverment Hospital and Dicle University Hospital during a 6-years period from September 2004 to September 2010. A total of 40 PICCs were inserted in 37 patients (26, 70% males, 11, 30% females) by using new technique. The median age of patients was 8.3 days (range 1 to 66 days) and the median weight of patients was 2365 g (range 600 to 5000 g). The vein most commonly accessed was long saphenous vein (85%). The length of PICCs in the body was 19.6 cm (range 5 cm to 30 cm). The tip was located in a central vein in all patients. Surgical abdomen was the most common cause for PICC insertion (38%). Duration of catheterization was 7.7±5.6 days (1-F 5.5 days, 2-F 8.6 days). Almost all of the PICCs were inserted successfully (40/42, success rate 95%) and in the first venipucture (36/42, 86%). Completion of therapy and removed after death were achieved with 87% of PICCs. Three minor complications were noted. Minor bleeding in the insertion site which was stopped via compression occurred in two neonates. Major complication was not seen. No deaths were directly attributed to PICCs use. The new insertion technique of the neonatal peripherally inserted central catheters may be one of the easiest and safest techniques, in comparison to previous techniques reported in the literature.
Skarlatos, S; Brand, P H; Metting, P J; Britton, S L
1994-01-01
1. Previous work has demonstrated a positive relationship between experimentally induced changes in arterial pressure (AP) and renal interstitial hydrostatic pressure (RIHP). The purpose of the present study was to test the hypothesis that RIHP is positively correlated with the normal changes in AP that occur spontaneously in conscious rats. 2. Rats were chronically instrumented for the recording of AP (via an aortic catheter) and RIHP. RIHP was measured by implanting a Millar microtransducer, whose tip had been encapsulated in a 35 microns pore polyethylene matrix (5 mm long, 2 mm o.d.), approximately 5 mm below the renal cortical surface. 3. A total of 56 h of simultaneous analog recording of AP and RIHP was obtained from ten rats. Each 1 h segment was digitized and evaluated at frequencies of 1, 0.1, 0.02 and 0.01 Hz. 4. In forty-nine out of fifty-six of these 1 h recordings taken at 1 Hz, there were significant positive linear correlations between AP and RIHP (mean r = 0.32) with a mean slope of 0.11 mmHg RIHP/1 mmHg AP. Low-pass filtering to 0.01 Hz significantly increased the r value to 0.48. 5. These results demonstrate that spontaneous changes in AP and RIHP are positively correlated. The spontaneous coupling of AP and RIHP may be of importance in the regulation of salt and water excretion by the pressure diuresis mechanism. PMID:7707240
Turbine blade with contoured chamfered squealer tip
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Ching-Pang
2014-12-30
A squealer tip formed from a pressure side tip wall and a suction side tip wall extending radially outward from a tip of the turbine blade is disclosed. The pressure and suction side tip walls may be positioned along the pressure sidewall and the suction sidewall of the turbine blade, respectively. The pressure side tip wall may include a chamfered leading edge with film cooling holes having exhaust outlets positioned therein. An axially extending tip wall may be formed from at least two outer linear surfaces joined together at an intersection forming a concave axially extending tip wall. The axiallymore » extending tip wall may include a convex inner surface forming a radially outer end to an inner cavity forming a cooling system. The cooling system may include one or more film cooling holes in the axially extending tip wall proximate to the suction sidewall, which promotes increased cooling at the pressure and suction sidewalls.« less
Intrapericardial echocardiography: a novel catheter-based approach to cardiac imaging.
Rodrigues, Ana Clara Tude; d'Avila, Andre; Houghtaling, Christopher; Ruskin, Jeremy N; Picard, Michael; Reddy, Vivek Y
2004-03-01
Transvascular catheter-based intracardiac echocardiography has been successfully used to help guide catheter ablation and electrophysiologic procedures. It has recently been demonstrated that catheters can be safely placed into the pericardial space to allow for epicardial cardiac mapping and ablation. We evaluated the feasibility of catheter-based intrapericardial echocardiography (IPE) during such procedures to identify cardiac structures and visualize intracardiac catheters. IPE was performed in 7 goats by placing a phased-array ultrasound transducer contained within a 10F steerable catheter into the pericardial space using the same transthoracic subxyphoid approach as used to map and ablate epicardial ventricular tachycardia. Images were obtained of cardiac structures and of intracardiac ablation catheters. After the procedure, the hearts were harvested to assess for possible IPE-related lesions. The IPE catheter could be easily placed inside the pericardial space in all animals. In 7 of 7 cases, longitudinal and short-axis views of right- and left-sided chambers and valves were obtained, similar in orientation to transesophageal echocardiography. Visualization of atrial appendages (6/7), pulmonary veins (6/7), coronary arteries (6/7), and coronary sinus (3/6) was also feasible. Assessment of intracardiac transvalvar and venous blood flow was achieved by spectral and color Doppler. The ablation catheter could be clearly visualized inside cardiac chambers. No arrhythmias were induced with IPE catheter manipulation. After harvesting the hearts, no lesions resulting from the procedure were observed. In this experimental setting, IPE was able to provide detailed images of cardiac structures and establish the relative position of the ablation catheter.
Feasibility of recanalization of human coronary arteries using high-intensity ultrasound.
Ernst, A; Schenk, E A; Woodlock, T J; Alliger, H; Gottlieb, S; Child, S Z; Meltzer, R S
1994-01-15
To investigate the feasibility of ultrasonic recanalization of obstructed human coronary arteries in vitro, high-intensity ultrasound was applied to 16 coronary arteries obtained at autopsy, using a prototype instrument enabling insonification through a catheter tip. It was a 119 cm long, 0.95 mm thick wire in an 8Fr catheter connected to an external ultrasonic transformer and power generator. A 5 MHz phased-array 2-dimensional echocardiography instrument was used to determine minimal luminal diameter and percent diameter narrowing before and after ultrasound application. The ultrasonic energy was delivered at 21.5 kHz and with a 52 +/- 19 micrometer average amplitude of tip displacement. The mean percent luminal diameter narrowing, flow rate and mean pressure gradient before ultrasound exposure were 74 +/- 11%, 97 +/- 61 ml/min, and 92 +/- 18 mm Hg, respectively. After recanalization, the mean percent luminal diameter narrowing decreased to 45 +/- 17% (p < 0.001), the mean flow rate increased to 84 +/- 92 ml/min (p < 0.001), and the mean pressure gradient was reduced to 45 +/- 24 mm Hg (p < 0.001). Of the debris particles, 95% had a diameter < 9 microns (range 5 to 12). Arterial perforation occurred in 5 of 16 arteries (31%) and all 5 occurred due to stiff wire manipulation and without ultrasound application. Mechanical fracture of the wire occurred in 8 cases (50%). No signs of thermal injury were found on histology. Thus, ultrasonic recanalization of human coronary arteries in vitro is feasible. It may reduce obstruction and improve blood flow. Debris sizes are sufficiently small to minimize the hazard of peripheral embolization.
Javan, Ramin; Zeman, Merissa N
2018-02-01
In the context of medical three-dimensional (3D) printing, in addition to 3D reconstruction from cross-sectional imaging, graphic design plays a role in developing and/or enhancing 3D-printed models. A custom prototype modular 3D model of the liver was graphically designed depicting segmental anatomy of the parenchyma containing color-coded hepatic vasculature and biliary tree. Subsequently, 3D printing was performed using transparent resin for the surface of the liver and polyamide material to develop hollow internal structures that allow for passage of catheters and wires. A number of concepts were incorporated into the model. A representative mass with surrounding feeding arterial supply was embedded to demonstrate tumor embolization. A straight narrow hollow tract connecting the mass to the surface of the liver, displaying the path of a biopsy device's needle, and the concept of needle "throw" length was designed. A connection between the middle hepatic and right portal veins was created to demonstrate transjugular intrahepatic portosystemic shunt (TIPS) placement. A hollow amorphous structure representing an abscess was created to allow the demonstration of drainage catheter placement with the formation of pigtail tip. Percutaneous biliary drain and cholecystostomy tube placement were also represented. The skills of graphic designers may be utilized in creating highly customized 3D-printed models. A model was developed for the demonstration and simulation of multiple hepatobiliary interventions, for training purposes, patient counseling and consenting, and as a prototype for future development of a functioning interventional phantom.
Ultrastructure of canine meninges after repeated epidural injection of S(+)-ketamine.
Acosta, Alinne; Gomar, Carmen; Bombí, Josep A; Graça, Dominguita L; Garrido, Marta; Krauspenhar, Cristina
2006-01-01
The safety of ketamine when administered by the spinal route must be confirmed in various animal species before it is approved for use in humans. This study evaluates the ultrastructure of canine meninges after repeated doses of epidural S(+)-ketamine. Five dogs received S(+)-ketamine 5%, 1 mg/kg, twice a day for 10 days through an epidural catheter with its tip located at the L5 level. One dog received the same volume of normal saline at the same times. The spinal cord and meninges were processed for histopathological and ultrastructural studies. Clinical effects were assessed after each injection. Motor and sensory block appeared after each injection of S(+)-ketamine, but not in the dog receiving saline. No signs of clinical or neurologic alterations were observed. Using light microscopy, no meningeal layer showed alterations except focal infiltration at the catheter tip level by macrophages, lymphocytes, and a few mast cells. The cells of different layers were studied by electron microscopy and interpreted according to data from human and other animal species because no ultrastructural description of the canine meninges is currently available. There were no cellular signs of inflammation, phagocytosis, or degeneration in meningeal layers and no signs of atrophy, compression, or demyelinization in the areas of dorsal root ganglia and spinal cord around the arachnoid. These findings were common for dogs receiving S(+)-ketamine and the dog receiving saline. Repeated doses of epidural S(+)-ketamine 5%, 1 mg/kg, twice a day for 10 days was not associated to cellular alterations in canine meninges.
Indocyanine green for intraoperative localization of ureter.
Siddighi, Sam; Yune, Junchan Joshua; Hardesty, Jeffrey
2014-10-01
Intraurethral injection of indocyanine green (ICG; Akorn, Lake Forest, IL) and visualization under near-infrared (NIR) light allows for real-time delineation of the ureter. This technology can be helpful to prevent iatrogenic ureteral injury during pelvic surgery. Patients were scheduled to undergo robot-assisted laparoscopic sacrocolpopexy. Before the robotic surgery started, the tip of a 6-F ureteral catheter was inserted into the ureteral orifice. Twenty-five milligrams of ICG was dissolved in 10-mL of sterile water and injected through the open catheter. The same procedure was repeated on the opposite side. The ICG reversibly stained the inside lining of the ureter by binding to proteins on urothelial layer. During the course of robotic surgery, the NIR laser on the da Vinci Si surgical robot (Intuitive Surgical, Inc, Sunnyvale, CA) was used to excite ICG molecules, and infrared emission was captured by the da Vinci filtered lens system and electronically converted to green color. Thus, the ureter fluoresced green, which allowed its definitive identification throughout the entire case. In all cases of >10 patients, we were able to visualize bilateral ureters with this technology, even though there was some variation in brightness that depended on the depth of the ureter from the peritoneal surface. For example, in a morbidly obese patient, the ureters were not as bright green. There were no intraoperative or postoperative adverse effects attributable to ICG administration for up to 2 months of observation. In our experience, this novel method of intraurethral ICG injection was helpful to identify the entire course of ureter and allowed a safe approach to tissues that were adjacent to the urinary tract. The advantage of our technique is that it requires the insertion of just the tip of ureteral catheter. Despite our limited cohort of patients, our findings are consistent with previous reports of the excellent safety profile of intravenous and intrabiliary ICG. Intraurethral injection of ICG and visualization under NIR light allows for real-time delineation of the ureter. This technology can be helpful to prevent iatrogenic ureteral injury during pelvic surgery. Copyright © 2014 Elsevier Inc. All rights reserved.
Werner, Gerald S
2011-01-01
In view of the improved long-term patency with drug-eluting stents, the challenge with chronic total coronary occlusion remains a low primary success rate. Modes of failure to open a chronic total coronary occlusion are mainly related to the inability to pass a wire through the proximal occlusion cap, and the most difficult part of the procedure is to guide the wire into the distal true lumen. A frequent situation is a subintimal wire position. The BridgePoint (BridgePoint Medical, MN, USA) family of devices is designed to cope with both of these problems. First, the CrossBoss™ catheter aims at passing through the proximal cap by manual rotation of a blunt proximal tip, and second, in case of a subintimal position, the Stingray™ balloon enables guided reentry from the subintimal space into the true lumen. Certain features of an occlusion might favor the CrossBoss device, while the reentry approach may also be used as a standalone bailout method. The aim is to provide a means to resolve otherwise failed attempts and to make it unnecessary to resort to the more complex and time-consuming retrograde wire techniques through collateral channels with the associated potential higher procedural risks.
[Application of injection test in confirming the ideal position of esophageal balloon catheter].
Chen, Han; Xu, Ming; Yang, Yanlin; He, Xuan; Zhou, Jianxin
2017-09-01
To evaluate the safety and feasibility of injection test which is used to locate esophageal balloon catheter. A prospective study was conducted. The patients undergoing invasive mechanical ventilation (MV) admitted to general intensive care unit (ICU) of Beijing Tiantan Hospital Affiliated to Capital Medical University from May 2015 and March 2017 were enrolled. The commercially available esophageal balloon catheter was modified to perform injection test. The catheter was withdrawn step by step and the injection test was repeated until the presence disturbance wave presented, which indicated that the balloon had just entered the esophagus. The position where disturbance wave appears was named 0 cm. End-expiratory occlusions were performed at the positions of +15, +10, +5, 0, -5, -10 and -15 cm, respectively, and the changes of esophageal pressure (Pes) and airway pressures (Paw) were measured in the spontaneous breathing and passive ventilation, and the ratio between the changes (ΔPes/ΔPaw) was calculated. A total of 20 patients were enrolled, of which 15 patients finished both the spontaneous and the passive ventilation parts, and 2 patients finished only the spontaneous part and 3 patients finished only passive part. (1) Disturbance waves could be induced by injection test in all patients. The average depth of disturbance wave in spontaneous breathing was deeper than that in passive ventilation (cm: 42.4±3.8 vs. 41.8±3.3), but there was no significant difference between the two ventilation settings (P = 0.132). No adverse events occurred during the study period. (2) Pes increased with the stepwise withdraw of esophageal catheter, reached the maximal value at +5 cm, and then decreased when the catheter was further withdrawn, no matter in the spontaneous or the passive ventilation. In spontaneous breathing, the ΔPes/ΔPaw was within the ideal range (0.8-1.2) at the positions of 0, -5 and -10 cm. The ΔPes/ΔPaw was closest to unity at the positions of 0 cm (0.98±0.15). The ΔPes/ΔPaw at -15 cm (0.66±0.26) was significantly lower than that at 0 cm (P < 0.05). For passive ventilation, the ΔPes/ΔPaw was within the ideal range at the positions of -5 cm and -10 cm, and the ΔPes/ΔPaw was closest to unity at the positions of -10 cm (0.94±0.12). The ΔPes/ΔPaw at 0 cm and -5 cm was significantly higher than that at -10 cm (1.43±0.31 and 1.12±0.14, respectively); while the ΔPes/ΔPaw at -15 cm (0.68±0.23) was significantly lower than that at -10 cm (all P < 0.01). Ideal position of the esophageal balloon catheter could be determined quickly and easily by using injection test. The method is safe and clinically feasible. Clinical Trials, NCT02446938.
Wang, Xiang; Dong, Yan; Qi, Xiang-Qian; Li, Yi-Ming; Huang, Cheng-Guang; Hou, Li-Jun
2013-07-25
To assess the efficacy of antimicrobial-impregnated catheters in preventing catheter-related infections during external ventricular drainage (EVD), we performed a meta-analysis and systematic review. We systematically searched Medline, Embase, and the Cochrane Library. All randomized controlled trials (RCTs) and nonrandomized prospective studies (NPSs) related to antimicrobial-impregnated EVD catheters were included. The primary outcome was the rate of cerebrospinal fluid infection (CFI). The secondary outcomes included the rate of time-dependent CFI and catheter bacterial colonization. We further performed subgroup analysis, meta-regression analysis, and microbial spectrum analysis. Four RCTs and four NPSs were included. The overall rate of CFIs was 3.6% in the antimicrobial-impregnated catheter group and 13.7% in the standard catheter group. The pooled data demonstrated that antimicrobial-impregnated catheters were superior to standard catheters in lowering the rate of CFIs (odds ratio (OR) = 0.25, 95% confidence interval (CI) = 0.12 to 0.52, P <0.05). In survival analysis, the 20-day infection rate was significantly reduced with the use of antimicrobial-impregnated catheters (hazard ratio = 0.52, 95% CI = 0.29 to 0.95, P <0.05). Furthermore, a significantly decreased rate of catheter bacterial colonization was noticed for antimicrobial-impregnated catheters (OR = 0.37, 95% CI = 0.21 to 0.64, P <0.05). In subgroup analyses, although significant results remained for RCTs and NPSs, a subgroup difference was revealed (P <0.05). Compared with standard catheters, a significantly lower rate of CFIs was noticed for clindamycin/rifampin-impregnated catheters (OR = 0.27, 95% CI = 0.10 to 0.73, P <0.05) and for minocycline/rifampin-impregnated catheters (OR = 0.11, 95% CI = 0.06 to 0.21, P <0.05). However, no statistical significance was found when compared with silver-impregnated catheters (OR = 0.33, 95% CI = 0.07 to 1.69, P = 0.18). In microbial spectrum analysis, antimicrobial-impregnated catheters were shown to have a lower rate of Gram-positive bacterial infection, particularly the coagulase-negative Staphylococcus. In conclusion, the use of antimicrobial-impregnated EVD catheters could be beneficial for the prevention of CFI and catheter bacterial colonization. Although antibiotic-coated catheters seem to be effective, no sufficient evidence supports the efficacy of silver-impregnated catheters.
2013-01-01
To assess the efficacy of antimicrobial-impregnated catheters in preventing catheter-related infections during external ventricular drainage (EVD), we performed a meta-analysis and systematic review. We systematically searched Medline, Embase, and the Cochrane Library. All randomized controlled trials (RCTs) and nonrandomized prospective studies (NPSs) related to antimicrobial-impregnated EVD catheters were included. The primary outcome was the rate of cerebrospinal fluid infection (CFI). The secondary outcomes included the rate of time-dependent CFI and catheter bacterial colonization. We further performed subgroup analysis, meta-regression analysis, and microbial spectrum analysis. Four RCTs and four NPSs were included. The overall rate of CFIs was 3.6% in the antimicrobial-impregnated catheter group and 13.7% in the standard catheter group. The pooled data demonstrated that antimicrobial-impregnated catheters were superior to standard catheters in lowering the rate of CFIs (odds ratio (OR) = 0.25, 95% confidence interval (CI) = 0.12 to 0.52, P <0.05). In survival analysis, the 20-day infection rate was significantly reduced with the use of antimicrobial-impregnated catheters (hazard ratio = 0.52, 95% CI = 0.29 to 0.95, P <0.05). Furthermore, a significantly decreased rate of catheter bacterial colonization was noticed for antimicrobial-impregnated catheters (OR = 0.37, 95% CI = 0.21 to 0.64, P <0.05). In subgroup analyses, although significant results remained for RCTs and NPSs, a subgroup difference was revealed (P <0.05). Compared with standard catheters, a significantly lower rate of CFIs was noticed for clindamycin/rifampin-impregnated catheters (OR = 0.27, 95% CI = 0.10 to 0.73, P <0.05) and for minocycline/rifampin-impregnated catheters (OR = 0.11, 95% CI = 0.06 to 0.21, P <0.05). However, no statistical significance was found when compared with silver-impregnated catheters (OR = 0.33, 95% CI = 0.07 to 1.69, P = 0.18). In microbial spectrum analysis, antimicrobial-impregnated catheters were shown to have a lower rate of Gram-positive bacterial infection, particularly the coagulase-negative Staphylococcus. In conclusion, the use of antimicrobial-impregnated EVD catheters could be beneficial for the prevention of CFI and catheter bacterial colonization. Although antibiotic-coated catheters seem to be effective, no sufficient evidence supports the efficacy of silver-impregnated catheters. PMID:23890254
[Peripheral intravenous catheter-related phlebitis].
van der Sar-van der Brugge, Simone; Posthuma, E F M Ward
2011-01-01
Phlebitis is a very common complication of the use of intravenous catheters. Two patients with an i.v. catheter complicated by thrombophlebitis are described. Patient A was immunocompromised due to chronic lymphatic leukaemia and developed septic thrombophlebitis with positive blood cultures for S. Aureus. Patient B was being treated with flucloxacillin because of an S. Aureus infection and developed chemical phlebitis. Septic phlebitis is rare, but potentially serious. Chemical or mechanical types of thrombophlebitis are usually less severe, but happen very frequently. Risk factors include: female sex, previous episode of phlebitis, insertion at (ventral) forearm, emergency placement and administration of antibiotics. Until recently, routine replacement of peripheral intravenous catheters after 72-96 h was recommended, but randomised controlled trials have not shown any benefit of this routine. A recent Cochrane Review recommends replacement of peripheral intravenous catheters when clinically indicated only.
Camkiran Firat, Aynur; Zeyneloglu, Pinar; Ozkan, Murat; Pirat, Arash
2016-09-01
To compare internal jugular vein and subclavian vein access for central venous catheterization in terms of success rate and complications. A 1:1 randomized controlled trial. Baskent University Medical Center. Pediatric patients scheduled for cardiac surgery. Two hundred and eighty children undergoing central venous catheterization were randomly allocated to the internal jugular vein or subclavian vein group during a period of 18 months. The primary outcome was the first-attempt success rate of central venous catheterization through either approach. The secondary outcomes were the rates of infectious and mechanical complications. The central venous catheterization success rate at the first attempt was not significantly different between the subclavian vein (69%) and internal jugular vein (64%) groups (p = 0.448). However, the overall success rate was significantly higher through the subclavian vein (91%) than the internal jugular vein (82%) (p = 0.037). The overall frequency of mechanical complications was not significantly different between the internal jugular vein (25%) and subclavian vein (31%) (p = 0.456). However, the rate of arterial puncture was significantly higher with internal jugular vein (8% vs 2%; p = 0.03) and that of catheter malposition was significantly higher with subclavian vein (17% vs 1%; p < 0.001). The rates per 1,000 catheter days for both positive catheter-tip cultures (26.1% vs 3.6%; p < 0.001) and central-line bloodstream infection (6.9 vs 0; p < 0.001) were significantly higher with internal jugular vein. There were no significant differences between the groups in the length of ICU and hospital stays or in-hospital mortality rates (p > 0.05 for all). Central venous catheterization through the internal jugular vein and subclavian vein was not significantly different in terms of success at the first attempt. Although the types of mechanical complications were different, the overall rate was similar between internal jugular vein and subclavian vein access. The risk of infectious complications was significantly higher with internal jugular vein access.
Chang, Chih-Hao; Huang, Myo-Ming; Yeih, Dong-Feng; Lu, Kuo-Cheng; Hou, Yi-Chou
2017-09-06
Isolated pulmonary valve infective endocarditis caused by Candida is rare in chronic hemodialysis patients. The 2009 Infectious Diseases Society of America guidelines suggest the combined use of surgery and antibiotics to treat candidiasis; however, successful nonsurgical treatment of Candida endocarditis has been reported. A 63-year-old woman with end-stage kidney disease was admitted to our hospital after experiencing disorientation for 5 days. The patient was permanently bedridden because of depression, and denied active intravenous drug use. She received maintenance hemodialysis through a tunneled-cuffed catheter. An initial blood culture grew Candida guilliermondii without other bacteria. Subsequent blood cultures and tip culture of tunneled-cuffed catheter also grew C. guilliermondii, even after caspofungin replaced fluconazole. A 1.2-cm mobile mass was observed on the pulmonary valve. Surgical intervention was suggested, but the family of the patient declined because of her multiple comorbidities. The patient was discharged with a prescription of fluconazole, but she died soon after. Our patient is the first case with isolated pulmonary valve endocarditis caused by C. guilliermondii in patients with uremia. Hematologic disorders, in addition to long-term central venous catheter use, prolonged antibiotic intravenous injection, and congenital cardiac anomaly, predispose to the condition. The diagnosis "isolated" pulmonary IE is difficult, and combing surgery with antifungal antibiotics is the appropriate therapeutic management for Candida related pulmonary IE.
Gröbner, Sabine; Heeg, Peter; Autenrieth, Ingo B; Schulte, Berit
2007-12-01
Ralstonia mannitolilytica is a non-fermentative, gram-negative bacterium isolated infrequently from clinical samples. However, within a period of 11 weeks five inpatients of the tertiary care hospital of the University of Tübingen developed clinical signs of infection and R. mannitolilytica was cultivated from blood samples of all patients suggesting an outbreak. Blood cultures and one catheter tip were analysed by standard microbiological procedures. Genetic relatedness of the isolates was investigated by pulsed-field gel electrophoresis. To ascertain the possible source of the outbreak, environmental sampling and challenge-recovery experiments to test filters used for multi-dose solution bottles were performed. In the present study a monoclonal outbreak with R. mannitolilytica causing catheter-related infection of five haematological patients is reported. Underlying severe diseases with consecutive immunosuppression, permanent indwelling intravenous devices, multiple intravenous applications, and chemotherapy were possible risk factors promoting the infection. Challenge-recovery experiments revealed that R. mannitolilytica to a high extent even passed through Mini-spike Plus filters of pore size 0.2 microm. Although the source of the outbreak could not be identified, it is possible that solutions given intravenously were contaminated. Since R. mannitolilytica had never been isolated in our laboratory before and environmental testings performed were negative, it cannot be excluded that commercial products like drugs, saline solutions or infusion systems (filters) were contaminated.
Erdogan, Ali; Grumbrecht, Stephan; Neumann, Thomas; Neuzner, Joerg; Pitschner, Heinz F
2003-01-01
The aim of the study was to compare the diameter of endomyocardial lesions induced with the delivery of microwave, cooled, or pulsed energy versus conventional RF energy. In vitro tests were performed in fresh endomyocardial preparations of pig hearts in a 10-L bath of NaCl 0.9% solution at 37 degrees C and constant 1.5 L/min flow. Ablation 7 Fr catheters with 4-mm tip electrodes were used, except for the delivery of microwave energy. Energy delivery time was set to 60 s/50 W in all experiments. Cooled energy delivery was performed with a closed irrigation catheter. Pulsed energy delivery was performed using a special controller with a duty-cycle of 5 ms. Microwave energy was delivered with a 2.5-GHz generator and 10-mm antenna. Electrode temperature and impedance were measured simultaneously. After ablation, lesion length, width, and depth were measured with microcalipers, and volume calculated by a formula for ellipsoid bodies. Each energy delivery mode was tested in ten experiments. The deepest lesions were created with cooled energy delivery, and the largest volume by microwave energy delivery. Pulsed RF produced significantly deeper lesions than conventional RF energy delivery. Cooled or pulsed RF energy delivery created deeper transmural lesions than conventional RF. To create linear lesions at anatomically complex sites (isthmus), microwave energy seemed superior by rapidly creating deep and long lesions.
[Rotation angioplasty of chronic coronary artery stenosis].
Kaltenbach, M; Vallbracht, C
1990-10-01
Coronary artery occlusion of more than six months duration can only rarely be recanalized with conventional techniques. For this reason, rotational angioplasty, which has been successfully applied for occlusion of peripheral arteries, has been employed in modified form for recanalization of chronic coronary artery occlusion. Rotational angioplasty is based on the concept that the slowly revolving, dull and relatively thick head of the flexible rotation catheter will seek the path of least resistance which, even in the case of relatively old arterial occlusions, mostly represents thrombotic material. The elastic, high-torque rotational catheter constructed of several V2A spiral steel wires has an interior lumen for insertion of exchange guidewires up to 0.014" and injection of contrast medium and an olive-shaped head of V2A steel with a diameter of 1.3 to 1.6 mm. A protection catheter made of polyethylene with metal markers and conically-tapered tip provides variable stiffness of the rotating catheter and protection of the endothelium in the proximal vascular segment. The slow rotation of 200 r.p.m. is performed with a small electric motor. Between April 1987 and February 1988, rotation angioplasty was performed in 20 patients, 17 with occlusion of the right coronary artery, two with occlusion of the left anterior descending artery and one with bypass graft occlusion to the left anterior descending artery in whom a conventional guidewire through the chronic occlusion could not be advanced. The duration of occlusion, based on previous angiograms anginal complaints or myocardial infarction, ranged from one month to twelve years, in twelve patients more than six months. In all patients, the indication for revascularization was clearly established.(ABSTRACT TRUNCATED AT 250 WORDS)
[Experimental ultrasound angioplasty: in vitro resolution of thrombi].
Stähr, P; Erbel, R; Weber, W; Fischer, H; Meyer, J
1995-05-01
A new ultrasonic angioplasty ablation catheter connected to a 19.5 kHz. 25 W transducer was tested in vitro for its ability to disrupt 12-h. 24-h, and 5-day-old whole blood thrombi (n = 45.697 mg +/- 223 mg) and fibrin thrombi (n = 45.338 mg +/- 133 mg), as well as 5-day-old cadaver thrombi (n = 8.270 mg +/- 71 mg) within 10 min. Five of each age were used as control thrombi in which the catheter was moved back and forth without ultrasound emission. The size of ablated thrombus particles was measured by a laser device. The power output at the end of the catheter was assessed calorimetrically. The loss of weight of whole blood thrombi was between 429 (74%) and 524 mg (91%) (p < 0.01, whole blood thrombi vs. control thrombi) and between 302 (85%) and 314 mg (95%) (p < 0.05) for fibrin thrombi, respectively. Thrombus age did not prove to be a highly significant influencing factor. The disruption rate for whole blood thrombi was 0.75 to 1.05 mg/s and for fibrin thrombi 0.69 to 0.7 mg/s. It was only 0.09 mg/s for the cadaver thrombi. 93% of all particles ablated from whole blood thrombus ranged between 0-5 micron, less than 0.2% between 30-150 microns. For fibrin thrombi 69% of all particles were < 10 microns (25% between 10-20 microns). Only 0.02% ranged between 300-600 microns, which was similar for cadaver thrombi. The mean measured power output at the catheter tip was 5.9 W compared to the power output of 25 W at the ultrasound generator.(ABSTRACT TRUNCATED AT 250 WORDS)
Visually guided male urinary catheterization: a feasibility study.
Willette, Paul A; Banks, Kevin; Shaffer, Lynn
2013-01-01
Ten percent to 15% of urinary catheterizations involve complications. New techniques to reduce risks and pain are indicated. This study examines the feasibility and safety of male urinary catheterization by nursing personnel using a visually guided device in a clinical setting. The device, a 0.6-mm fiber-optic bundle inside a 14F triple-lumen flexible urinary catheter with a lubricious coating, irrigation port, and angled tip, connects to a camera, allowing real-time viewing of progress on a color monitor. Two emergency nurses were trained to use the device. Male patients 18 years or older presenting to the emergency department with an indication for urinary catheterization using a standard Foley or Coudé catheter were eligible to participate in the study. Exclusion criteria were a current suprapubic tube or gross hematuria prior to the procedure. Twenty-five patients were enrolled. Data collected included success of placement, total procedure time, pre-procedure pain and maximum pain during the procedure, gross hematuria, abnormalities or injuries identified if catheterization failed, occurrence of and reason for equipment failures, and number of passes required for placement. All catheters were successfully placed. The median number of passes required was 1. For all but one patient, procedure time was ≤ 17 minutes. A median increase in pain scores of 1 point from baseline to the maximum was reported. Gross hematuria was observed in 2 patients. The success rate for placement of a Foley catheter with the visually guided device was 100%, indicating its safety, accuracy, and feasibility in a clinical setting. Minimal pain was associated with the procedure. Copyright © 2013 Emergency Nurses Association. Published by Mosby, Inc. All rights reserved.
[Experimental study of angiography using vascular interventional robot-2(VIR-2)].
Tian, Zeng-min; Lu, Wang-sheng; Liu, Da; Wang, Da-ming; Guo, Shu-xiang; Xu, Wu-yi; Jia, Bo; Zhao, De-peng; Liu, Bo; Gao, Bao-feng
2012-06-01
To verify the feasibility and safety of new vascular interventional robot system used in vascular interventional procedures. Vascular interventional robot type-2 (VIR-2) included master-slave parts of body propulsion system, image navigation systems and force feedback system, the catheter movement could achieve under automatic control and navigation, force feedback was integrated real-time, followed by in vitro pre-test in vascular model and cerebral angiography in dog. Surgeon controlled vascular interventional robot remotely, the catheter was inserted into the intended target, the catheter positioning error and the operation time would be evaluated. In vitro pre-test and animal experiment went well; the catheter can enter any branch of vascular. Catheter positioning error was less than 1 mm. The angiography operation in animal was carried out smoothly without complication; the success rate of the operation was 100% and the entire experiment took 26 and 30 minutes, efficiency was slightly improved compared with the VIR-1, and the time what staff exposed to the DSA machine was 0 minute. The resistance of force sensor can be displayed to the operator to provide a security guarantee for the operation. No surgical complications. VIR-2 is safe and feasible, and can achieve the catheter remote operation and angiography; the master-slave system meets the characteristics of traditional procedure. The three-dimensional image can guide the operation more smoothly; force feedback device provides remote real-time haptic information to provide security for the operation.
Subarachnoid and basal cistern navigation through the sacral hiatus with guide wire assistance.
Layer, Lauren; Riascos, Roy; Firouzbakht, Farhood; Amole, Adewumi; Von Ritschl, Rudiger; Dipatre, Pier; Cuellar, Hugo
2011-07-01
Intraspinal navigation with catheters and fiberscopes has shown feasible results for diagnosis and treatment of intraspinal and intracranial lesions. The most common approach, lumbar puncture, has allowed access to the spinal cord, however, coming with the difficulties of fiberscope damage and decreased torque for guidance. Our objective in this study is to allow an alternate access, the sacral hiatus, with guide wire assistance into the subarachnoid and intracranial structures, while easing the angle of entry and increasing torque. We advanced catheters with guide wire and fluoroscopy assistance into the sacral hiatus of three cadavers. After entry, the thecal sac was punctured and the catheter with guide wire was advanced rostrally until positioned in the basal cisterns of the brain. We confirmed catheter placement with contrast injection, autopsy, and dissection. In our study, the sacral hiatus was easily accessed, but resistance was found when attempting to puncture the thecal sac. The advancement of the catheter with guide wire assistance glided easily rostrally until some mild resistance was discovered at entry into the foramen magnum. With redirection, all catheters passed with ease into the basal cisterns. Positioning was confirmed with contrast injection with fluoroscopy evidence, autopsy, and dissection. There was no macroscopic or microscopic evidence of damage to the spinal roots, spinal cord, or cranial nerves. The sacral hiatus with guide wire assistance is an accessible conduit for uncomplicated entry into the subarachnoid and basal cistern space without damaging surrounding structures.
Jauch, K. W.; Schregel, W.; Stanga, Z.; Bischoff, S. C.; Braß, P.; Hartl, W.; Muehlebach, S.; Pscheidl, E.; Thul, P.; Volk, O.
2009-01-01
Catheter type, access technique, and the catheter position should be selected considering to the anticipated duration of PN aiming at the lowest complication risks (infectious and non-infectious). Long-term (>7–10 days) parenteral nutrition (PN) requires central venous access whereas for PN <3 weeks percutaneously inserted catheters and for PN >3 weeks subcutaneous tunnelled catheters or port systems are appropriate. CVC (central venous catheter) should be flushed with isotonic NaCl solution before and after PN application and during CVC occlusions. Strict indications are required for central venous access placement and the catheter should be removed as soon as possible if not required any more. Blood samples should not to be taken from the CVC. If catheter infection is suspected, peripheral blood-culture samples and culture samples from each catheter lumen should be taken simultaneously. Removal of the CVC should be carried out immediately if there are pronounced signs of local infection at the insertion site and/or clinical suspicion of catheter-induced sepsis. In case PN is indicated for a short period (max. 7–10 days), a peripheral venous access can be used if no hyperosmolar solutions (>800 mosm/L) or solutions with a high titration acidity or alkalinity are used. A peripheral venous catheter (PVC) can remain in situ for as long as it is clinically required unless there are signs of inflammation at the insertion site. PMID:20049083
Akbari, Roghayeh; Rahmani Firouzi, Sedigheh; Akbarzadeh-Pasha, Abazar
2017-01-01
Introduction: Renal transplantation is the treatment of choice in chronic renal failure patients. Objectives: The purpose of this study was to evaluate the impact of urinary catheter removal time on transplanted kidney size and incidence of asymptomatic bacteriuria and urinary tract infections (UTIs). Patients and Methods: This retrospective cohort study evaluated the clinical outcomes of 109 consecutive live donor renal transplant recipients from December 2011 to July 2014. Routine ultrasound examinations were performed on donor's kidney prior to operation and one month later. Kidney volume was calculated. UTI and bacteriuria were evaluated one month later. Patients were divided into two groups based on time of Foley catheter removal (before and after fifth day posttransplantation). Results: In this study 74 males (67.9%) and 35 females (32.1%) were evaluated. Sixty-six patients (57.92%) were in group 1. None of the patients with positive urine culture had UTI but bacteriuria occurred in all of them (21.1%). Bacteriuria time after transplantation and catheter removal was significantly later in group 1 and it was not different in female group but they were later in male group. The mean renal volume increase was positively correlated to renal transplant recipient and donor's age and donor's body mass index (BMI) ( P <0.05). Conclusion: This study showed that the time of catheter removal after kidney transplantation does not affect incidence of UTI but increases the probability of bacteria in men whose catheter was removed within 5 days after transplantation. We also found that the renal volume change is not associated with catheter removal time and bacteriuria.