[Ultrasound-guided peripheral catheterization].
Salleras-Duran, Laia; Fuentes-Pumarola, Concepció
2016-01-01
Peripheral catheterization is a technique that can be difficult in some patients. Some studies have recently described the use of ultrasound to guide the venous catheterization. To describe the success rate, time required, complications of ultrasound-guided peripheral venous catheterization. and patients and professionals satisfaction The search was performed in databases (Medline-PubMed, Cochrane Library, CINAHL and Cuiden Plus) for studies published about ultrasound-guided peripheral venous catheterization performed on patients that provided results on the success of the technique, complications, time used, patient satisfaction and the type of professional who performed the technique. A total of 21 studies were included. Most of them get a higher success rate 80% in the catheterization ecoguide and time it is not higher than the traditional technique. The Technical complications analyzed were arterial puncture rates and lower nerve 10%. In all studies measuring and comparing patient satisfaction in the art ecoguide is greater. Various professional groups perform the technique. The use of ultrasound for peripheral pipes has a high success rate, complications are rare and the time used is similar to that of the traditional technique. The technique of inserting catheters through ultrasound may be learned by any professional group performing venipuncture. Finally, it gets underscores the high patient satisfaction with the use of this technique. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.
Myocardial blood flow: Roentgen videodensitometry techniques
NASA Technical Reports Server (NTRS)
Smith, H. C.; Robb, R. A.; Wood, E. H.
1975-01-01
The current status of roentgen videodensitometric techniques that provide an objective assessment of blood flow at selected sites within the coronary circulation were described. Roentgen videodensitometry employs conventional radiopaque indicators, radiological equipment and coronary angiographic techniques. Roentgen videodensitometry techniques developed in the laboratory during the past nine years, and for the past three years were applied to analysis of angiograms in the clinical cardiac catheterization laboratory.
Evaluation of ultrasound-guided vascular access in dogs.
Chamberlin, Scott C; Sullivan, Lauren A; Morley, Paul S; Boscan, Pedro
2013-01-01
To describe the technique and determine the feasibility, success rate, perceived difficulty, and time to vascular access using ultrasound guidance for jugular vein catheterization in a cardiac arrest dog model. Prospective descriptive study. University teaching hospital. Nine Walker hounds. A total of 27 jugular catheterizations were performed postcardiac arrest using ultrasound guidance. Catheterizations were recorded based on the order in which they were performed and presence/absence of a hematoma around the vein. Time (minutes) until successful vascular access and perceived difficulty in achieving vascular access (scale of 1 = easy to 10 = difficult) were recorded for each catheterization. Mean time to vascular access was 1.9 minutes (95% confidence interval, 1.1-3.4 min) for catheterizations without hematoma, versus 4.3 minutes (1.8-10.1 min) for catheterizations with hematoma (P = 0.1). Median perceived difficulty was 2 of 10 (range 1-7) for catheterizations without hematoma, versus 2 of 10 (range 1-8) for catheterizations with hematoma (P = 0.3). A learning curve was evaluated by comparing mean time to vascular access and perceived difficulty in initial versus subsequent catheterizations. Mean time to vascular access was 2.5 minutes (1.0-6.4 min) in the initial 13 catheterizations versus 3.3 minutes (1.5-7.5 min) in the subsequent 14 catheterizations (P = 0.6). Median perceived difficulty in the first 13 catheterizations (3, range 1-8) was significantly greater (P = 0.049) than median perceived difficulty in the subsequent 14 catheterizations (2, range 1-6). Ultrasound-guided jugular catheterization is associated with a learning curve but is successful in obtaining rapid vascular access in dogs. Further prospective studies are warranted to confirm the utility of this technique in a clinical setting. © Veterinary Emergency and Critical Care Society 2013.
Osei, Frank A; Hayman, Joshua; Sutton, Nicole J; Pass, Robert H
2016-01-01
Background: Cardiac catheterizations expose both the patient and staff to the risks of ionizing radiation. Studies using the “air gap” technique (AGT) in various radiological procedures indicate that its use leads to reduction in radiation exposure but there are no data on its use for pediatric cardiac catheterization. The aim of this study was to retrospectively review the radiation exposure data for children weighing <20 kg during cardiac catheterizations using AGT and an “as low as reasonably achievable (ALARA)” radiation reduction protocol. Patients and Methods: All patients weighing <20 kg who underwent cardiac catheterization at the Children's Hospital at Montefiore (CHAM), New York, the United States from 05/2011 to 10/2013 were included. Transplant patients who underwent routine endomyocardial biopsy and those who had surgical procedures at the time of the catheterizations were excluded. The ALARA protocol was used in concert with AGT with the flat panel detector positioned 110 cm from the patient. Demographics, procedural data, and patient radiation exposure levels were collected and analyzed. Results: One-hundred and twenty-seven patients underwent 151 procedures within the study period. The median age was 1.2 years (range: 1 day to 7.9 years) and median weight was 8.8 kg (range: 1.9-19.7). Eighty-nine (59%) of the procedures were interventional. The median total fluoro time was 13 min [interquartile range (IQR) 7.3-21.8]. The median total air Kerma (K) product was 55.6 mGy (IQR 17.6-94.2) and dose area product (DAP) was 189 Gym2 (IQR 62.6-425.5). Conclusion: Use of a novel ALARA and AGT protocol for cardiac catheterizations in children markedly reduced radiation exposure to levels far below recently reported values. Abbreviations: AGT: Air gap technique, ALARA: As low as reasonably achievable. PMID:27011686
Net, P; Karnycheff, F; Vasse, M; Bourdain, F; Bonan, B; Lapergue, B
2018-03-01
Urinary catheterization and acute urinary retention increase the risk of urinary tract infection (UTI). Our study aimed to investigate the incidence of UTI following acute stroke at our stroke center (SC) and to assess urinary catheter-care practices among French SCs. Stroke patients hospitalized within 24h of stroke onset were prospectively enrolled between May and September 2013. Neurological deficit level was assessed on admission using the US National Institutes of Health Stroke Scale (NIHSS). Patients were followed-up until discharge. Indwelling urinary catheterization (IUC) was the only technique authorized during the study. An electronic survey was also conducted among French SCs to assess their practices regarding urinary catheterization in acute stroke patients. A total of 212 patients were included, with 45 (21.2%) receiving indwelling urinary catheters. The overall estimated incidence of UTI was 14.2%, and 18% among patients receiving IUC. On univariate analysis, IUC was significantly associated with older age, longer hospital stays and higher NIHSS scores. Of the 30 SCs that responded to our survey, 19 (63.3%) declared using IUC when urinary catheterization was needed. The main argument given to justify its use was that it was departmental policy to adopt this technique. Also, 27 participants (90%) stated that conducting a study to assess the impact of urinary catheterization techniques on UTI rates in acute stroke patients would be relevant. Our results are in accord with previously reported data and confirm the high burden of UTI among acute stroke subjects. However, no association was found between IUC and UTI on univariate analysis due to a lack of statistical power. Also, our survey showed high heterogeneity in catheter-use practices among French SCs, but offered no data to help determine the best urinary catheterization technique. Urinary catheterization is common after acute stroke and a well-known risk factor of UTI. However, as high heterogeneity in catheter-use practices is found among French SCs, randomized studies comparing the efficacy of urinary catheterization techniques in terms of UTI prevention in acute stroke patients are now warranted. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
A new technique for long time catheterization of sacral epidural canal in rabbits.
Erkin, Yüksel; Aydın, Zeynep; Taşdöğen, Aydın; Karcı, Ayşe
2013-01-01
In this study we aimed to develop a simple and practical technique for chronic sacral epidural catheterization of rabbits. We included ten rabbits weighing 2-2.5 kg in the study. After anesthesia and analgesia, we placed an epidural catheter by a 2 cm longitudinal skin incision in the tail above the sacral hiatus region. We confirmed localization by giving 1% lidocaine (leveling sensory loss and motor function loss of the lower extremity). The catheter was carried forward through a subcutaneous tunnel and fixed at the neck. Chronic caudal epidural catheter placement was succesful in all rabbits. The catheters stayed in place effectively for ten days. We encountered no catheter complications during this period. The localization of the catheter was reconfirmed by 1% lidocaine on the last day. After animals killing, we performed a laminectomy and verified localization of the catheter in the epidural space. Various methods for catheterization of the epidural space in animal models exist in the literature. Epidural catheterization of rabbits can be accomplished by atlanto-occipital, lumbar or caudal routes by amputation of the tail. Intrathecal and epidural catheterization techniques defined in the literature necessitate surgical skill and knowledge of surgical procedures like laminectomy and tail amputation. Our technique does not require substantial surgical skill, anatomical integrity is preserved and malposition of the catheter is not encountered. In conclusion, we suggest that our simple and easily applicable new epidural catheterization technique can be used as a model in experimental animal studies.
Visually guided male urinary catheterization: a feasibility study.
Willette, Paul A; Banks, Kevin; Shaffer, Lynn
2013-01-01
Ten percent to 15% of urinary catheterizations involve complications. New techniques to reduce risks and pain are indicated. This study examines the feasibility and safety of male urinary catheterization by nursing personnel using a visually guided device in a clinical setting. The device, a 0.6-mm fiber-optic bundle inside a 14F triple-lumen flexible urinary catheter with a lubricious coating, irrigation port, and angled tip, connects to a camera, allowing real-time viewing of progress on a color monitor. Two emergency nurses were trained to use the device. Male patients 18 years or older presenting to the emergency department with an indication for urinary catheterization using a standard Foley or Coudé catheter were eligible to participate in the study. Exclusion criteria were a current suprapubic tube or gross hematuria prior to the procedure. Twenty-five patients were enrolled. Data collected included success of placement, total procedure time, pre-procedure pain and maximum pain during the procedure, gross hematuria, abnormalities or injuries identified if catheterization failed, occurrence of and reason for equipment failures, and number of passes required for placement. All catheters were successfully placed. The median number of passes required was 1. For all but one patient, procedure time was ≤ 17 minutes. A median increase in pain scores of 1 point from baseline to the maximum was reported. Gross hematuria was observed in 2 patients. The success rate for placement of a Foley catheter with the visually guided device was 100%, indicating its safety, accuracy, and feasibility in a clinical setting. Minimal pain was associated with the procedure. Copyright © 2013 Emergency Nurses Association. Published by Mosby, Inc. All rights reserved.
Khandelwal, Aditi; Devine, Luke A; Otremba, Mirek
2017-07-01
Many instructional materials for point-of-care ultrasound (US)-guided procedures exist; however, their quality is unknown. This study assessed widely available educational videos for point-of-care US-guided procedures relevant to internal medicine: central venous catheterization, thoracentesis, and paracentesis. We searched Ovid MEDLINE, YouTube, and Google to identify videos for point-of-care US-guided paracentesis, thoracentesis, and central venous catheterization. Videos were evaluated with a 5-point scale assessing the global educational value and a checklist based on consensus guidelines for competencies in point-of-care US-guided procedures. For point-of-care US-guided central venous catheterization, 12 videos were found, with an average global educational value score ± SD of 4.5 ± 0.7. Indications to abort the procedure were discussed in only 3 videos. Five videos described the indications and contraindications for performing central venous catheterization. For point-of-care US-guided thoracentesis, 8 videos were identified, with an average global educational value score of 4.0 ± 0.9. Only one video discussed indications to abort the procedure, and 3 videos discussed sterile technique. For point-of-care US-guided paracentesis, 7 videos were included, with an average global educational value score of 4.1 ± 0.9. Only 1 video discussed indications to abort the procedure, and 2 described the location of the inferior epigastric artery. The 27 videos reviewed contained good-quality general instruction. However, we noted a lack of safety-related information in most of the available videos. Further development of resources is required to teach internal medicine trainees skills that focus on the safety of point-of-care US guidance. © 2017 by the American Institute of Ultrasound in Medicine.
Safety of latex urinary catheters for the short time drainage
Hosseinpour, Mehrdad; Noori, Saeed; Amir-Beigi, Mahdieh; Pourfakharan, Mohammad Hassan; Ehteram, Hassan; Hamsayeh, Mohadese
2014-01-01
Background: In this study, we attempt to identify the most appropriate catheter (silicone vs. latex) for short-term urinary catheterization. We compared the post-operative clinico-pathological complications between latex and silicone for short term catheterization in rabbits with hypospadias. Materials and Methods: Forty rabbits were used in our study to compare complications of catheterization. They were divided in two groups. Hypospadias like defect was created by a 1 cm long excision of the ventral urethra. For urethroplasty, we used tubularized incised plate technique. Latex and silicon catheters were used in groups 1 and 2, respectively. Post-operatively, routine laboratory urine test and complications (allergy, infection, bleeding) were compared in groups. Results: A total of 40 rabbits underwent hypospadias repair. Findings showed that there were no significant differences between groups based on urine test indices (P = NS). Urinary tract infection rate was 10% (2 rabbits) in latex and 0% in silicone groups (P = NS). There were no significant differences between groups regarding of cystitis grades between study groups (P = NS). Conclusion: It seems that urinary tract catheterization with latex catheters is a safe, feasible, and in-expensive procedure for short-term post-operative course in hypospadias surgery in patients without latex hypersensitivity. PMID:25125890
Purdy, Phillip D; South, Charles; Klucznik, Richard P; Liu, Kenneth C; Novakovic, Robin L; Puri, Ajit S; Pride, G Lee; Aagaard-Kienitz, Beverly; Ray, Abishek; Elliott, Alan C
2017-01-01
Purpose Monitoring of blood pressure (BP) during procedures is variable, depending on multiple factors. Common methods include sphygmomanometer (BP cuff), separate radial artery catheterization, and side port monitoring of an indwelling sheath. Each means of monitoring has disadvantages, including time consumption, added risk, and signal dampening due to multiple factors. We sought an alternative approach to monitoring during procedures in the catheterization laboratory. Methods A new technology involving a 330 µm fiberoptic sensor embedded in the wall of a sheath structure was tested against both radial artery catheter and sphygmomanometer readings obtained simultaneous with readings recorded from the pressure sensing system (PSS). Correlations and Bland–Altman analysis were used to determine whether use of the PSS could substitute for these standard techniques. Results The results indicated highly significant correlations in systolic, diastolic, and mean arterial pressures (MAP) when compared against radial artery catheterization (p<0.0001), and MAP means differed by <4%. Bland–Altman analysis of the data suggested that the sheath measurements can replace a separate radial artery catheter. While less striking, significant correlations were seen when PSS readings were compared against BP cuff readings. Conclusions The PSS has competitive functionality to that seen with a dedicated radial artery catheter for BP monitoring and is available immediately on sheath insertion without the added risk of radial catheterization. The sensor is structurally separated from the primary sheath lumen and readings are unaffected by device introduction through the primary lumen. Time delays and potential complications from radial artery catheterization are avoided. PMID:27422970
Teilmann, Anne Charlotte; Rozell, Björn; Kalliokoski, Otto; Hau, Jann; Abelson, Klas S P
2016-01-01
Automated blood sampling through a vascular catheter is a frequently utilized technique in laboratory mice. The potential immunological and physiological implications associated with this technique have, however, not been investigated in detail. The present study compared plasma levels of the cytokines IL-1β, IL-2, IL-6, IL-10, IL-17A, GM-CSF, IFN-γ and TNF-α in male NMRI mice that had been subjected to carotid artery catheterization and subsequent automated blood sampling with age-matched control mice. Body weight and histopathological changes in the surgical area, including the salivary glands, the heart, brain, spleen, liver, kidneys and lungs were compared. Catheterized mice had higher levels of IL-6 than did control mice, but other cytokine levels did not differ between the groups. No significant difference in body weight was found. The histology revealed inflammatory and regenerative (healing) changes at surgical sites of all catheterized mice, with mild inflammatory changes extending into the salivary glands. Several catheterized mice had multifocal degenerative to necrotic changes with inflammation in the heart, kidneys and livers, suggesting that thrombi had detached from the catheter tip and embolized to distant sites. Thus, catheterization and subsequent automated blood sampling may have physiological impact. Possible confounding effects of visceral damage should be assessed and considered, when using catheterized mouse models.
Yamakawa, Akira; Fujita, Atsushi; Tanaka, Hirotomo; Ikeda, Mitsuru; Morikawa, Masashi; Kohmura, Eiji
2017-07-01
Tentorial dural arteriovenous fistulas(dAVFs)are a rare clinical entity accounting for less than 10% of all intracranial dAVFs. Because these lesions are characterized by high hemorrhagic risk, aggressive treatment should be considered. Although the number of reported cases treated with endovascular transarterial embolization(TAE)using glue has been increasing, little is known about the transvenous approach. Here, we report the case of a patient with a tentorial dAVF who was successfully treated with transvenous embolization(TVE)through venous drainage using a double catheterization technique. A 68-year-old male patient who had a history of left putaminal hemorrhage treated with a craniotomy was diagnosed with a tentorial dAVF on a magnetic resonance angiogram. Because the patient refused another craniotomy for surgical interruption of the dAVF, an endovascular approach was considered. We first attempted to perform TAE with glue, but catheterization into the tortuous meningohypophyseal trunk failed. We then performed a TVE of the venous drainage near the shunt with detachable coils and achieved complete obliteration of the fistula. During coil embolization of the venous drainage, insertion of small coils near the shunt was supported by another anchor coil that was delivered using a double catheterization technique. The method of TVE through venous drainage using a double catheterization technique, which involved placing coils in the fragile drainage vein, was safe and effective in a case of tentorial dAVF. This technique should be considered as another option for the management of complex tentorial dAVFs.
Purdy, Phillip D; South, Charles; Klucznik, Richard P; Liu, Kenneth C; Novakovic, Robin L; Puri, Ajit S; Pride, G Lee; Aagaard-Kienitz, Beverly; Ray, Abishek; Elliott, Alan C
2017-08-01
Monitoring of blood pressure (BP) during procedures is variable, depending on multiple factors. Common methods include sphygmomanometer (BP cuff), separate radial artery catheterization, and side port monitoring of an indwelling sheath. Each means of monitoring has disadvantages, including time consumption, added risk, and signal dampening due to multiple factors. We sought an alternative approach to monitoring during procedures in the catheterization laboratory. A new technology involving a 330 µm fiberoptic sensor embedded in the wall of a sheath structure was tested against both radial artery catheter and sphygmomanometer readings obtained simultaneous with readings recorded from the pressure sensing system (PSS). Correlations and Bland-Altman analysis were used to determine whether use of the PSS could substitute for these standard techniques. The results indicated highly significant correlations in systolic, diastolic, and mean arterial pressures (MAP) when compared against radial artery catheterization (p<0.0001), and MAP means differed by <4%. Bland-Altman analysis of the data suggested that the sheath measurements can replace a separate radial artery catheter. While less striking, significant correlations were seen when PSS readings were compared against BP cuff readings. The PSS has competitive functionality to that seen with a dedicated radial artery catheter for BP monitoring and is available immediately on sheath insertion without the added risk of radial catheterization. The sensor is structurally separated from the primary sheath lumen and readings are unaffected by device introduction through the primary lumen. Time delays and potential complications from radial artery catheterization are avoided. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Zhang, Xicheng; Sun, Yuan; Chen, Zhaolei; Jing, Yuanhu; Xu, Miao
2017-08-01
A retrograde technique through the gap between the distal stent landing zone and the iliac artery wall has been applied to treat type II endoleak after endovascular aortic aneurysm repair (EVAR). In this study, we tried to investigate its efficacy in the management of type III endoleak and intraoperative accidental events. We reported 2 complications of EVAR that were difficult to treat with conventional methods. One patient had a sustained type III endoleak after EVAR, and the right renal artery was accidentally sealed by a graft stent in the other patient during the operation. Both complications were managed by the retrograde technique from the distal stent landing zone. In the first case, the endoleak was easily embolized by the retrograde catheterization technique, and in the second case, a stent was implanted in the right renal artery using the retrograde technique to restore blood flow. In some EVAR cases, the technique of retrograde catheterization through the distal stent-graft landing zone is feasible, safe, and easy to perform.
Ultrasound Guidance as a Rescue Technique for Peripheral Intravenous Cannulation
2006-09-14
painful, time consuming, and may result in arterial puncture, nerve damage, and paresthes ias.5 Other routes such as central venous or venous cut down...peripherally inserted central lines-PICCS), femoral catheterizations during cardiopulmonary resuscitation, and peripheral IV catheters in difficult...techniques for gaining venous access. What to do when peripheral intravenous catheterization is not possible. J Crit 11/n. 1993;8:435-442. 2. Nee PA
Kopach, Olga; Krotov, Volodymyr; Voitenko, Nana
2017-10-01
Catheterization has been widely used in neuroscience and pain research for local drug delivery. Though different modifications were developed, the use of young animals for spinal catheterization remains limited because of a little success rate. A reliable technique is needed to catheterize young animals aimed for in vivo testing combined with spinal cord electrophysiology, often limited by animal age, to facilitate pain research. We describe intrathecal catheterization of young rats (3-week-old) through atlanto-occipical approach for long-lasting drug delivery into the lumbar subarachnoid space. The technique represents a surgical approach of minimized invasiveness that requires PE-10 catheter and few equipment of standard laboratory use. Behavioral assessments revealed that spinal catheterization does not change peripheral sensitivity of different modalities (thermal and mechanical) and gives no rise to locomotive deficit or anxiety-like behavior in young rats. The long-term administration of genetic material (oligodeoxynucleotides given up to 4days), examined both in vivo and in situ, produced no adverse effects on basal peripheral sensitivity, but changed the AMPA receptor-mediated currents in sensory interneurons of the spinal cord. Dissimilar to already described methods, the method is designed for the use of young rats for behavioral testing in vivo and/or spinal cord electrophysiology in situ. A practical method for spinal catheterization of young animals designed for studies in vivo and in situ is proposed. The method is rapid and effective and should facilitate investigation of therapeutic effects on both systemic and subcellular levels, as an advantage over the existing methods. Copyright © 2017 Elsevier B.V. All rights reserved.
Ureteric catheterization via an ileal conduit: technique and retrieval of a JJ stent.
Wah, T M; Kellett, M J
2004-11-01
Retrograde ureteric catheterization of a patient with an ileal conduit is difficult, because guide wires and catheters coil in the conduit. A modified loopogram, using a Foley catheter as a fulcrum through which catheters can be advanced to the ureteric anastomosis, is described. This technique was used to remove a JJ stent, which had been inserted previously across a stricture in one ureter, the stent crossing from one kidney to the other.
An orthotopic model of murine bladder cancer.
Dobek, Georgina L; Godbey, W T
2011-02-06
In this straightforward procedure, bladder tumors are established in female C57 mice through the use of catheterization, local cauterization, and subsequent cell adhesion. After their bladders are transurethrally catheterized and drained, animals are again catheterized to permit insertion of a platinum wire into bladders without damaging the urethra or bladder. The catheters are made of Teflon to serve as an insulator for the wire, which will conduct electrical current into the bladder to create a burn injury. An electrocautery unit is used to deliver 2.5W to the exposed end of the wire, burning away extracellular layers and providing attachment sites for carcinoma cells that are delivered in suspension to the bladder through a subsequent catheterization. Cells remain in the bladder for 90 minutes, after which the catheters are removed and the bladders allowed to drain naturally. The development of tumor is monitored via ultrasound. Specific attention is paid to the catheterization technique in the accompanying video.
Zohar, Y
1980-01-01
The use of a dorsal aorta catheterization technique to study gonadotropin secretion patterns in the rainbow trout was tested. Heparin used to flush the cannula between repetitive samplings did not have any effect on plasma GTH levels. Catheterization resulted in a slight short-term change in those levels. The gonadotropin levels returned to their initial values as soon as 30 min to 6 hrs after the operation. From then on, the GTH levels remained close to the initial values in fish exhibiting normal feeding behaviour, whereas they tended to decrease in "stressed" females which did not eat normally. The fish which adapted well to dorsal aortic catheterization did not show any changes in the diurnal pattern of GTH levels or in normal gonadal function and GTH profiles during the processes of oocyte maturation and ovulation. It is concluded that individual catheterized trout can be used advantageously for studying gonadotropin secretion patterns after a 3-day recovery period and the elimination of those fish which neither resume normal feeding nor return to initial, pre-operative GTH levels. Using this technique, it was demonstrated that hypophysial GTH release in trout with oocytes undergoing active vitellogenesis is probably effected by short-term bursts (pulses) of secretion.
Radiation Dose Estimation for Pediatric Patients Undergoing Cardiac Catheterization
NASA Astrophysics Data System (ADS)
Wang, Chu
Patients undergoing cardiac catheterization are potentially at risk of radiation-induced health effects from the interventional fluoroscopic X-ray imaging used throughout the clinical procedure. The amount of radiation exposure is highly dependent on the complexity of the procedure and the level of optimization in imaging parameters applied by the clinician. For cardiac catheterization, patient radiation dosimetry, for key organs as well as whole-body effective, is challenging due to the lack of fixed imaging protocols, unlike other common X-ray based imaging modalities. Pediatric patients are at a greater risk compared to adults due to their greater cellular radio-sensitivities as well as longer remaining life-expectancy following the radiation exposure. In terms of radiation dosimetry, they are often more challenging due to greater variation in body size, which often triggers a wider range of imaging parameters in modern imaging systems with automatic dose rate modulation. The overall objective of this dissertation was to develop a comprehensive method of radiation dose estimation for pediatric patients undergoing cardiac catheterization. In this dissertation, the research is divided into two main parts: the Physics Component and the Clinical Component. A proof-of-principle study focused on two patient age groups (Newborn and Five-year-old), one popular biplane imaging system, and the clinical practice of two pediatric cardiologists at one large academic medical center. The Physics Component includes experiments relevant to the physical measurement of patient organ dose using high-sensitivity MOSFET dosimeters placed in anthropomorphic pediatric phantoms. First, the three-dimensional angular dependence of MOSFET detectors in scatter medium under fluoroscopic irradiation was characterized. A custom-made spherical scatter phantom was used to measure response variations in three-dimensional angular orientations. The results were to be used as angular dependence correction factors for the MOSFET organ dose measurements in the following studies. Minor angular dependence (< +/-20% at all angles tested, < +/-10% at clinically relevant angles in cardiac catheterization) was observed. Second, the cardiac dose for common fluoroscopic imaging techniques for pediatric patients in the two age groups was measured. Imaging technique settings with variations of individual key imaging parameters were tested to observe the quantitative effect of imaging optimization or lack thereof. Along with each measurement, the two standard system output indices, the Air Kerma (AK) and Dose-Area Product (DAP), were also recorded and compared to the measured cardiac and skin doses -- the lack of correlation between the indices and the organ doses shed light to the substantial limitation of the indices in representing patient radiation dose, at least within the scope of this dissertation. Third, the effective dose (ED) for Posterior-Anterior and Lateral fluoroscopic imaging techniques for pediatric patients in the two age groups was determined. In addition, the dosimetric effect of removing the anti-scatter grid was studied, for which a factor-of-two ED rate reduction was observed for the imaging techniques. The Clinical Component involved analytical research to develop a validated retrospective cardiac dose reconstruction formulation and to propose the new Optimization Index which evaluates the level of optimization of the clinician's imaging usage during a procedure; and small sample group of actual procedures were used to demonstrate applicability of these formulations. In its entirety, the research represents a first-of-its-kind comprehensive approach in radiation dosimetry for pediatric cardiac catheterization; and separately, it is also modular enough that each individual section can serve as study templates for small-scale dosimetric studies of similar purposes. The data collected and algorithmic formulations developed can be of use in areas of personalized patient dosimetry, clinician training, image quality studies and radiation-associated health effect research.
Percutaneous Treatment of Splenic Cystic Echinococcosis: Results of 12 Cases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akhan, Okan, E-mail: akhano@tr.net; Akkaya, Selçuk, E-mail: selcuk.akkaya85@gmail.com; Dağoğlu, Merve Gülbiz, E-mail: drmgkartal@gmail.com
PurposeCystic echinococcosis (CE) in the spleen is a rare disease even in endemic regions. The aim of this study was to examine the efficacy of percutaneous treatment for splenic CE.Materials and MethodsTwelve patients (four men, eight women) with splenic CE were included in this study. For percutaneous treatment, CE1 and CE3A splenic hydatid cysts were treated with either the PAIR (puncture, aspiration, injection, respiration) technique or the catheterization technique.ResultsEight of the hydatid cysts were treated with the PAIR technique and four were treated with catheterization. The volume of all cysts decreased significantly during the follow-up period. No complication occurred inmore » seven of 12 patients. Abscess developed in four patients. Two patients underwent splenectomy due to cavity infection developed after percutaneous treatment, while the spleen was preserved in 10 of 12 patients. Total hospital stay was between 1 and 18 days. Hospital stay was longer and the rate of infection was higher in the catheterization group. Follow-up period was 5–117 months (mean, 44.8 months), with no recurrence observed.ConclusionThe advantages of the percutaneous treatment are its minimal invasive nature, short hospitalization duration, and its ability to preserve splenic tissue and function. As the catheterization technique is associated with higher abscess risk, we suggest that the PAIR procedure should be the first percutaneous treatment option for splenic CE.« less
The effect of anesthetization and urinary bladder catheterization on renal function of rainbow trout
Hunn, J.B.; Willford, W.A.
1970-01-01
1. Rainbow trout were anesthetized with MS-222 (Sandoz) or methylpentynol and catheterized. Urine was collected at selected intervals up to 48 hr. 2. Effects of MS-222 anesthesia on urine flow and composition were isolated from the stress of catheterization by re-anesthetizing the fish 18 to 20 hr post catheterization. 3. Urine output patterns were similar following MS-222 or methylpentynol anesthesia and catheterization. Highest urine flows were measured 4 to 8 hr post treatment. The highest urine output after re-anesthetization with MS-222 was observed 2 to 4 hr post-anesthesia. 4. Highest concentrations of Na2+, K+, Ca2+, Cl- and inorganic PO4 in the urine were measured in the first 2 hr after anesthesia and catheterization. 5. Flow rates and chemical composition of urine indicate that "normal" renal function is re-established 12 to 24 hr post-treatment.
Trends in cardiac catheterization laboratories in the United States.
Sheldon, W C
2001-05-01
The Society for Cardiac Angiography and Interventions has periodically published a Directory of Cardiac Catheterization Laboratories in the United States. All known catheterization laboratories are surveyed and certain operational characteristics are queried. These surveys, in 1983, 1987, 1993, 1995 and 1998, have demonstrated a 2.5 fold increase in cardiac catheterization laboratories since 1983, corresponding increases in numbers of physicians that perform procedures, and in the numbers of procedures performed, reflecting advances in cardiovascular medicine and technology. These surveys have also documented the evolution of interventional techniques, and a shift away from film based imaging, to digitally based methods. These data provide a substrate for consideration of national cardiovascular objectives and planning of future resource allocation by cardiovascular physicians and their colleagues. Copyright 2001 Wiley-Liss, Inc.
Healy, Eibhlín F; Walsh, Colin A; Cotter, Amanda M; Walsh, Stewart R
2012-09-01
Suprapubic catheterization is commonly used for postoperative bladder drainage after gynecologic procedures. However, recent studies have suggested an increased rate of complications compared with urethral catheterization. We undertook a systematic review and meta-analysis of randomized controlled trials comparing suprapubic catheterization and urethral catheterization in gynecologic populations. PubMed, EMBASE, CINAHL, Google Scholar, and trial registries were searched from 1966 to March 2012 for eligible randomized controlled trials comparing postoperative suprapubic catheterization and urethral catheterization in gynecologic patients. We used these search terms: "catheter," "supra(-)pubic catheter," "urinary catheter," "gyn(a)ecological," "catheterization techniques gyn(a)ecological surgery," "transurethral catheter," and "bladder drainage." No language restrictions were applied. METHODS AND STUDY SELECTION: The primary outcome was urinary tract infection. Secondary outcomes were the need for recatheterization, duration of catheterization, catheter-related complications, and duration of hospital stay. Pooled effect size estimates were calculated using the random effects model from DerSimonian and Laird. In total, 12 eligible randomized controlled trials were included in the analysis (N=1,300 patients). Suprapubic catheterization was associated with a significant reduction in postoperative urinary tract infections (20% compared with 31%, pooled odds ratio [OR] 0.31, 95% confidence interval [CI] 0.185-0.512, P<.01) but an increased risk of complications (29% compared with 11%, pooled OR 4.14, 95% CI 1.327-12.9, P=.01). Complications were mostly related to catheter tube malfunction with no visceral injuries reported. No differences in the rate of recatheterization or hospital stay were demonstrated. Robust patient satisfaction and cost-effectiveness data are lacking. Based on the best available evidence, no route for bladder drainage in gynecologic patients is clearly superior. The reduced rate of infective morbidity with suprapubic catheterization is offset by a higher rate of catheter-related complications and crucially does not translate into reduced hospital stay. As yet, there are insufficient data to determine which route is most appropriate for catheterization; therefore, cost and patient-specific factors should be paramount in the decision. Minimally invasive surgery may alter the requirement for prolonged postoperative catheterization.
Ultrasound guidance for internal jugular vein cannulation: Continuing Professional Development.
Ayoub, Christian; Lavallée, Catherine; Denault, André
2010-05-01
The objective of this continuing professional development module is to describe the role of ultrasound for central venous catheterization and to specify its benefits and limitations. Although ultrasound techniques are useful for all central venous access sites, the focus of this module is on the internal jugular vein approach. In recent years, several studies were published on the benefits of ultrasound use for central venous catheterization. This technique has evolved rapidly due to improvements in the equipment and technology available. Ultrasound helps to detect the anatomical variants of the internal jugular vein. The typical anterolateral position of the internal jugular vein with respect to the carotid is found in only 9-92% of cases. Ultrasound guidance reduces the rate of mechanical, infectious, and thrombotic complications by 57%, and it also reduces the failure rate by 86%. Cost-benefit analyses show that the cost of ultrasound equipment is compensated by the decrease in the expenses associated with the treatment of complications. In this article, we will review the history of ultrasound guidance as well as the reasons that account for its superiority over the classical anatomical landmark technique. We will describe the equipment needed for central venous catheterization as well as the various methods to visualize with ultrasound. To improve patient safety, we recommend the use of ultrasound for central venous catheterization using the internal jugular approach.
Hascoët, Sebastien; Warin-Fresse, Karine; Baruteau, Alban-Elouen; Hadeed, Khaled; Karsenty, Clement; Petit, Jérôme; Guérin, Patrice; Fraisse, Alain; Acar, Philippe
2016-02-01
Cardiac catheterization has contributed to the progress made in the management of patients with congenital heart disease (CHD). First, it allowed clarification of the diagnostic assessment of CHD, by offering a better understanding of normal cardiac physiology and the pathophysiology and anatomy of complex malformations. Then, it became an alternative to surgery and a major component of the therapeutic approach for some CHD lesions. Nowadays, techniques have evolved and cardiac catheterization is widely used to percutaneously close intracardiac shunts, to relieve obstructive valvar or vessel lesions, and for transcatheter valve replacement. Accurate imaging is mandatory to guide these procedures. Cardiac imaging during catheterization of CHD must provide accurate images of lesions, surrounding cardiac structures, medical devices and tools used to deliver them. Cardiac imaging has to be 'real-time' with an excellent temporal resolution to ensure 'eyes-hands' synchronization and 'device-target area' accurate positioning. In this comprehensive review, we provide an overview of conventional cardiac imaging tools used in the catheterization laboratory in daily practice, as well as the effect of recent evolution and future imaging modalities. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morishita, Hiroyuki, E-mail: hmorif@koto.kpu-m.ac.jp, E-mail: mori-h33@xa2.so-net.ne.jp; Takeuchi, Yoshito, E-mail: yotake62@qg8.so-net.ne.jp; Ito, Takaaki, E-mail: takaaki@koto.kpu-m.ac.jp
2016-06-15
PurposeThe purpose of the study was to retrospectively evaluate the efficacy and safety of the balloon blocking technique (BBT).Materials and MethodsThe BBT was performed in six patients (all males, mean 73.5 years) in whom superselective catheterization for transcatheter arterial embolization by the conventional microcatheter techniques had failed due to anatomical difficulty, including targeted arteries originating steeply or hooked from parent arteries. All BBT procedures were performed using Seldinger’s transfemoral method. Occlusive balloons were deployed and inflated at the distal side of the target artery branching site in the parent artery via transfemoral access. A microcatheter was delivered from a 5-F cathetermore » via another femoral access and was advanced over the microguidewire into the target artery, under balloon blockage of advancement of the microguidewire into non-target branches. After the balloon catheter was deflated and withdrawn, optimal interventions were performed through the microcatheter.ResultsAfter success of accessing the targeted artery by BBT, optimal interventions were accomplished in all patients with no complications other than vasovagal hypotension, which responded to nominal therapy.ConclusionThe BBT may be useful in superselective catheterization of inaccessible arteries due to anatomical difficulties.« less
Mogollón Jiménez, M V; Escoresca Ortega, A M; Cabeza Letrán, M L; Hinojosa Pérez, R; Lage Gallé, E; Sobrino Márquez, J M; Herruzo Avilés, A; Romero Rodríguez, N; Frutos López, M; Pérez de la Yglesia, R; Martínez Martínez, A
2008-11-01
Invasive assessment of pulmonary artery pressure (PAP), via right heart catheterization, is part of the usual protocol prior to heart transplantation. Echocardiography is considered a valuable technique to evaluate PAP. We sought to determine the reliability of measurements of PAP via a noninvasive technique, echocardiography, in relation to the estimated PAP via right catheterization. We also determined its safety when invasive procedures are restricted to just patients with pulmonary hypertension (PHT) according to echocardiographic parameters. We performed a retrospective study of 67 right catheterizations performed in our hospital, within the heart transplant study protocol, from January 2000 to December 2006. PAP parameters were estimated by echocardiography and right catheterization. Hemodynamically, 57.1% of the patients had severe PHT (more than 45 mm Hg mean PAP); 13.2% moderate PHT (between 35 and 45 mm Hg mean PAP); 12.1% had mild PHT (between 25 and 35 mm Hg mean PAP); and 17.6% of patients showed no PHT. Pearson correlation index with systolic PAP (estimated via echocardiography) and mean PAP (calculated via invasive method) was 0.69 (P < .001). PHT was considered significant when systolic PAP estimated via echocardiography reached more than 40 mm Hg and mean PAP estimated via right catheterization reached more than 35 mm Hg, the value from which the vasodilator test was carried out. According to these parameters, echocardiography showed a sensitivity of 89% to diagnose significant PHT and 46% specificity, with positive and negative predictive values of 70% and 76%, respectively.
Dalela, Divakar; Gupta, Piyush; Dalela, Disha; Srinivas, A K; Bhaskar, Ved; Govil, Tuhina; Goel, Apul; Sankhwar, Satya Narayan
2016-08-01
To assess the safety and effectiveness of a novel transurethral bougie-guided monorail technique for suprapubic catheterization in females with vesicovaginal fistula. Patients undergoing transvaginal vesicovaginal fistula repair from February 2013 to December 2013 were selected. Suprapubic catheter was placed using this technique and assessment was done in terms of time taken, intraprocedural dislodgement or entanglement of catheter during the procedure, bleeding from the anterior abdominal wall or urethra, or any other intraoperative difficulty. All patients were catheterized smoothly without any intraoperative difficulty, with a mean time of 6 minutes. We describe a new technique of performing suprapubic cystostomy in patients, especially where the bladder cannot be distended. It is safe and easy to perform. Copyright © 2016 Elsevier Inc. All rights reserved.
Cardiac catheterization laboratory inpatient forecast tool: a prospective evaluation
Flanagan, Eleni; Siddiqui, Sauleh; Appelbaum, Jeff; Kasper, Edward K; Levin, Scott
2016-01-01
Objective To develop and prospectively evaluate a web-based tool that forecasts the daily bed need for admissions from the cardiac catheterization laboratory using routinely available clinical data within electronic medical records (EMRs). Methods The forecast model was derived using a 13-month retrospective cohort of 6384 catheterization patients. Predictor variables such as demographics, scheduled procedures, and clinical indicators mined from free-text notes were input to a multivariable logistic regression model that predicted the probability of inpatient admission. The model was embedded into a web-based application connected to the local EMR system and used to support bed management decisions. After implementation, the tool was prospectively evaluated for accuracy on a 13-month test cohort of 7029 catheterization patients. Results The forecast model predicted admission with an area under the receiver operating characteristic curve of 0.722. Daily aggregate forecasts were accurate to within one bed for 70.3% of days and within three beds for 97.5% of days during the prospective evaluation period. The web-based application housing the forecast model was used by cardiology providers in practice to estimate daily admissions from the catheterization laboratory. Discussion The forecast model identified older age, male gender, invasive procedures, coronary artery bypass grafts, and a history of congestive heart failure as qualities indicating a patient was at increased risk for admission. Diagnostic procedures and less acute clinical indicators decreased patients’ risk of admission. Despite the site-specific limitations of the model, these findings were supported by the literature. Conclusion Data-driven predictive analytics may be used to accurately forecast daily demand for inpatient beds for cardiac catheterization patients. Connecting these analytics to EMR data sources has the potential to provide advanced operational decision support. PMID:26342217
In situ cephalic vein bypasses from axillary to the brachial artery after catheterization injuries.
Hudorovic, Narcis; Lovricevic, Ivo; Ahel, Zaky
2010-07-01
The need to bypass to the brachial artery is rare. Over a five-year period, 16 patients had suffered iatrogenic post-catheterization injuries of the upper extremity. We have performed 16 bypasses, in 16 patients, mean age was 65 years (range 47-75), to the brachial artery originating from an artery proximal to the shoulder joint. In all cases, the axillary artery was the donor artery. All bypasses were created by using the cephalic vein with the in situ technique and distal anastomoses were made to a distance-free section of brachial artery. No operative mortality, neurological complications or major upper-extremity amputation was associated with the procedure. Life-long-conduit analysis showed 75% patency in the five-year period. After iatrogenic post-catheterization trauma of arterial system of upper extremity, bypasses from axillary to brachial artery with the cephalic vein with the in situ technique is a safe operation with satisfactory long-term patency.
Chair, Sek Ying; Chau, Mei Yi; Sit, Janet Wing Hung; Wong, Eliza Mei Ling; Chan, Aileen Wai Kiu
2012-02-01
Coronary artery disease (CAD) is one of the leading causes of death and morbidity worldwide, and cardiac catheterization plays an essential role in its diagnostic evaluation. This quasi-experimental study examined the effectiveness of an educational intervention with the use of videotape and pamphlet among the Chinese patient undergoing the cardiac catheterization, and explored the relationship between anxiety, uncertainty, and other psychological variables. One hundred and thirty two Chinese patients of diagnosed or suspected CAD preparing for the first-time catheterization were recruited. Anxiety level (the Chinese State Anxiety Inventory) and uncertainty (the Chinese version of Mishel Uncertainty in Illness Scale) were measured before the intervention and within 2 hours before receiving cardiac catheterization; while patients' satisfaction and perceived knowledge gain were measured at 20-24 hours after it. The mean age of the participants was 61.3 and 64.8% of them were male. The findings indicated that the use of videotape to prepare patients for the cardiac catheterization is effective in reducing the level of anxiety (p < 0.001) and the uncertainty (p < 0.001), as the patients experienced higher satisfaction and knowledge level after the educational intervention. Therefore, videotape education is suggested for cardiac catheterization care on top of the usual pamphlet education.
A simple technique to facilitate treatment of urethral strictures with optical internal urethrotomy.
Stamatiou, Konstantinos; Papadatou, Aggeliki; Moschouris, Hippocrates; Kornezos, Ioannis; Pavlis, Anargiros; Christopoulos, Georgios
2014-01-01
Urethral stricture is a common condition that can lead to serious complications such as urinary infections and renal insufficiency secondary to urinary retention. Treatment options include catheterization, urethroplasty, endoscopic internal urethrotomy, and dilation. Optical internal urethrotomy offers faster recovery, minimal scarring, and less risk of infection, although recurrence is possible. However, technical difficulties associated with poor visualization of the stenosis or of the urethral lumen may increase procedural time and substantially increase the failure rates of internal urethrotomy. In this report we describe a technique for urethral catheterization via a suprapubic, percutaneous approach through the urinary bladder in order to facilitate endoscopic internal urethrotomy.
Riveros, Ricardo; Makarova, Natalya; Riveros-Perez, Efrain; Chodavarapu, Praneeta; Saasouh, Wael; Yılmaz, Hüseyin Oğuz; Cuko, Evis; Babazade, Rovnat; Kimatian, Stephen; Turan, Alparslan
2017-12-01
Dexmedetomidine is increasingly used in children undergoing cardiac catheterization procedures. We compared the percentage of surgical time with hemodynamic instability and the incidence of postoperative agitation between pediatric cardiac catheterization patients who received dexmedetomidine infusion and those who did not and the incidence of postoperative agitation. We matched 653 pediatric patients scheduled for cardiac catheterization. Two separate multivariable linear mixed models were used to assess the association between dexmedetomidine use and intraoperative blood pressure and heart rate instability. A multivariate logistic regression was used for relationship between dexmedetomidine and postoperative agitation. No difference between the study groups was found in the duration of MAP ( P = .867) or heart rate (HR) instabilities ( P = .224). The relationship between dexmedetomidine use and the duration of negative hemodynamic effects does not depend on any of the considered CHD types (all P > .001) or intervention ( P = .453 for MAP and P = .023 for HR). No difference in postoperative agitation was found between the study groups ( P = .590). Our study demonstrated no benefit in using dexmedetomidine infusion compared with other general anesthesia techniques to maintain hemodynamic stability or decrease agitation in pediatric patients undergoing cardiac catheterization procedures.
Patel, Manesh R; Bailey, Steven R; Bonow, Robert O; Chambers, Charles E; Chan, Paul S; Dehmer, Gregory J; Kirtane, Ajay J; Wann, L Samuel; Ward, R Parker
2012-05-29
The American College of Cardiology Foundation, in collaboration with the Society for Cardiovascular Angiography and Interventions and key specialty and subspecialty societies, conducted a review of common clinical scenarios where diagnostic catheterization is frequently considered. The indications (clinical scenarios) were derived from common applications or anticipated uses, as well as from current clinical practice guidelines and results of studies examining the implementation of noninvasive imaging appropriate use criteria. The 166 indications in this document were developed by a diverse writing group and scored by a separate independent technical panel on a scale of 1 to 9, to designate appropriate use (median 7 to 9), uncertain use (median 4 to 6), and inappropriate use (median 1 to 3). Diagnostic catheterization may include several different procedure components. The indications developed focused primarily on 2 aspects of diagnostic catheterization. Many indications focused on the performance of coronary angiography for the detection of coronary artery disease with other procedure components (e.g., hemodynamic measurements, ventriculography) at the discretion of the operator. The majority of the remaining indications focused on hemodynamic measurements to evaluate valvular heart disease, pulmonary hypertension, cardiomyopathy, and other conditions, with the use of coronary angiography at the discretion of the operator. Seventy-five indications were rated as appropriate, 49 were rated as uncertain, and 42 were rated as inappropriate. The appropriate use criteria for diagnostic catheterization have the potential to impact physician decision making, healthcare delivery, and reimbursement policy. Furthermore, recognition of uncertain clinical scenarios facilitates identification of areas that would benefit from future research.
Puymirat, Etienne; Blanchard, Didier; Perier, Marie-Cécile; PiaDonataccio, Maria; Gilard, Martine; Lefèvre, Thierry; Mulak, Geneviève; le Breton, Hervé; Danchin, Nicolas; Spaulding, Christian; Jouven, Xavier
2013-08-01
The national observational study of diagnostic and interventional cardiac catheterization (ONACI) is a prospective multicenter registry of the French Society of Cardiology including all interventional cardiology procedures performed from 2004. We aimed to evaluate "real-world" management of patients with coronary artery disease in France from this registry. The present study was focused on data collected from 2004 to 2008. Patient demographics and co-morbidities, invasive parameters, treatment options, and procedural techniques were prospectively collected. Patients were recruited from 99 hospitals (55% of patients were hospitalized in private clinics and 45% in public institutions). During a 5-year period, a total of 298,105 patients underwent coronary angiography and 176,166 patients underwent percutaneous coronary intervention. Diagnosis was acute coronary syndrome in 22%, stable angina or silent ischemia in 23%, and atypical chest pain in 9% of cases. Normal coronary arteries or nonsignificant coronary narrowing were found in 26% of patients. Radial access was increasingly used over the years regardless of the indication. The average number of percutaneous coronary interventions per procedure was 1.5 ± 0.7 (range, 1.3 ± 0.7 to 1.5 ± 0.7) and that of stents per procedure was 1.5 ± 0.8 (range, 1.5 ± 0.8 to 1.6 ± 0.8). Drug-eluting stents were used in 45% (range, 34% to 62%), increasing from 2004 to 2006, and then decreasing after the 2006 controversy. In conclusion, ONACI is one of the largest catheterization registries during this period, providing a detailed and comprehensive global description of the spectrum and management of patients with suspected coronary artery disease undergoing cardiac catheterization. Copyright © 2013 Elsevier Inc. All rights reserved.
Oxygen Breathing Accelerates Decompression from Saturation at 40 msw in 70-kg Swine
2010-07-01
2010 0 2 AFfER A DEEP SATURATION DIVE-PETERSEN ET AL. REFERENCES 1. Bain SA, Tmg J, Simeonovic CJ, Wilson JO. Technique of venous catheterization ...was catheterized with a 16-gauge by 20.3-cm single lumen catheter (Braun Certofix; B. Braun Medical Inc., Bethlehem, PA) via the modified Seldinger...respiratory distress, as evidenced by open-mouthed, labored breathing, central cyanosis, or the production of frothy white sputum. The onset of se- vere
Girard, R; Gaujard, S; Pergay, V; Pornon, P; Martin Gaujard, G; Vieux, C; Bourguignon, L
2015-07-01
Controlling urinary tract infections (UTIs) associated with intermittent catheterization in geriatric patients. After a local epidemiological study identified high rates of UTI, a multi-disciplinary working group implemented and evaluated corrective measures. In 2009, a one-month prospective study measured the incidence of UTI, controlled for risk factors and exposure, in six geriatric hospitals. In 2010, a self-administered questionnaire on practices was administered to physicians and nurses working in these geriatric units. In 2011, the working group developed a multi-modal programme to: improve understanding of micturition, measurement of bladder volume and indications for catheter drainage; limit available medical devices; and improve prescription and traceability procedures. Detailed training was provided to all personnel on all sites. The epidemiological study was repeated in 2012 to assess the impact of the programme. Over 1500 patients were included in the 2009 study. The incidence of acquired infection was 4.8%. The infection rate was higher in patients with intermittent catheters than in patients with indwelling catheters (29.7 vs 9.9 UTI per 100 patients, P = 0.1013) which contradicts the literature. In 2010, the 269 responses to the questionnaire showed that staff did not consider catheterization to place patients at risk of infection, staff had poor knowledge of the recommended indications and techniques, and the equipment varied widely between units. Following implementation of the programme, the study was repeated in 2012 with over 1500 patients. The frequency of UTI in patients with intermittent catheters fell to rates in the published literature. Multi-modal programmes are an effective means to control UTI. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
2009-02-01
catheterized with an external jugular catheter via the Seldinger technique and allowed to recover. Subjects were exposed to 132 feet of seawater (fsw) in...the external jugular vein of the animal was catheterized with a 16 gauge by 20.3 cm single lumen catheter (Braun Certofix; B. Braun Medical Inc... central cyanosis or the production of frothy white sputum. The onset of severe DCS (neurological or cardio-pulmonary dysfunction) and all behavioral
Perz, Sarah; Ellimoottil, Chandy; Rao, Manoj; Bresler, Larissa
2013-01-01
Bladder stones account for 5% of all urinary stone disease and can develop on a foreign body, such as a misplaced suture, eroded surgical mesh, or ureteral stent. In this case study, the authors present a patient with bladder stones associated with pubic hairs introduced during a monthly indwelling Foley catheter change. Clinicians have an important role in instructing patients on the use of proper technique and hygiene practices during urethral catheterization to minimize the potential for urinary complications.
Qureshi-5 Catheter for Complex Supra- and Abdominal-Aortic Catheterization
Qureshi, Adnan I.; Xiao, WeiGang; Liu, HongLiang
2015-01-01
Background The use of previously described catheter technique was expanded to complex supra- and abdominal- aortic catheterizations. Methods A new (Qureshi 5) catheter with curved shape at the distal end that has two lumens was used. One of lumens can accommodate a 0.035-inch guide wire and the second lumen can accommodate a 0.018-inch guide wire and terminates at the beginning of the distal curve of the first lumen. The manipulation and engagement of the curved distal end catheter was facilitated by rotation and movement of the J-shaped 0.018-inch guide wire extended coaxial and beyond the distal end of catheter. Subsequently, either contrast was injected or a 0.035-inch guide wire advanced into the target artery. Results The catheters were used in one patient to perform diagnostic cerebral and abdominal angiography through a 6F introducer sheath placed in the right common femoral artery. The catheterization was complex because of severe tortuosity of arch and descending aorta secondary to kyphosis. The left and right internal carotid arteries and left and right vertebral arteries, left renal artery, and superior mesenteric artery were catheterized in patient (fluoroscopy time 19:46 min). No complications were observed in the patient. Conclusions The Qureshi-5 catheter was successful in complex supra- and abdominal-aortic catheterizations. PMID:26600925
Qureshi-5 Catheter for Complex Supra- and Abdominal-Aortic Catheterization.
Qureshi, Adnan I; Xiao, WeiGang; Liu, HongLiang
2015-10-01
The use of previously described catheter technique was expanded to complex supra- and abdominal- aortic catheterizations. A new (Qureshi 5) catheter with curved shape at the distal end that has two lumens was used. One of lumens can accommodate a 0.035-inch guide wire and the second lumen can accommodate a 0.018-inch guide wire and terminates at the beginning of the distal curve of the first lumen. The manipulation and engagement of the curved distal end catheter was facilitated by rotation and movement of the J-shaped 0.018-inch guide wire extended coaxial and beyond the distal end of catheter. Subsequently, either contrast was injected or a 0.035-inch guide wire advanced into the target artery. The catheters were used in one patient to perform diagnostic cerebral and abdominal angiography through a 6F introducer sheath placed in the right common femoral artery. The catheterization was complex because of severe tortuosity of arch and descending aorta secondary to kyphosis. The left and right internal carotid arteries and left and right vertebral arteries, left renal artery, and superior mesenteric artery were catheterized in patient (fluoroscopy time 19:46 min). No complications were observed in the patient. The Qureshi-5 catheter was successful in complex supra- and abdominal-aortic catheterizations.
Cardiac catheterization - discharge
Catheterization - cardiac - discharge; Heart catheterization - discharge: Catheterization - cardiac; Heart catheterization; Angina - cardiac catheterization discharge; CAD - cardiac catheterization discharge; Coronary artery disease - cardiac catheterization ...
Catheterization - cardiac; Heart catheterization; Angina - cardiac catheterization; CAD - cardiac catheterization; Coronary artery disease - cardiac catheterization; Heart valve - cardiac catheterization; Heart failure - ...
Patel, Manesh R; Bailey, Steven R; Bonow, Robert O; Chambers, Charles E; Chan, Paul S; Dehmer, Gregory J; Kirtane, Ajay J; Wann, L Samuel; Ward, R Parker; Douglas, Pamela S; Patel, Manesh R; Bailey, Steven R; Altus, Philip; Barnard, Denise D; Blankenship, James C; Casey, Donald E; Dean, Larry S; Fazel, Reza; Gilchrist, Ian C; Kavinsky, Clifford J; Lakoski, Susan G; Le, D Elizabeth; Lesser, John R; Levine, Glenn N; Mehran, Roxana; Russo, Andrea M; Sorrentino, Matthew J; Williams, Mathew R; Wong, John B; Wolk, Michael J; Bailey, Steven R; Douglas, Pamela S; Hendel, Robert C; Kramer, Christopher M; Min, James K; Patel, Manesh R; Shaw, Leslee; Stainback, Raymond F; Allen, Joseph M
2012-09-01
The American College of Cardiology Foundation, in collaboration with the Society for Cardiovascular Angiography and Interventions and key specialty and subspecialty societies, conducted a review of common clinical scenarios where diagnostic catheterization is frequently considered. The indications (clinical scenarios) were derived from common applications or anticipated uses, as well as from current clinical practice guidelines and results of studies examining the implementation of noninvasive imaging appropriate use criteria. The 166 indications in this document were developed by a diverse writing group and scored by a separate independent technical panel on a scale of 1 to 9, to designate appropriate use (median 7 to 9), uncertain use (median 4 to 6), and inappropriate use (median 1 to 3). Diagnostic catheterization may include several different procedure components. The indications developed focused primarily on 2 aspects of diagnostic catheterization. Many indications focused on the performance of coronary angiography for the detection of coronary artery disease with other procedure components (e.g., hemodynamic measurements, ventriculography) at the discretion of the operator. The majority of the remaining indications focused on hemodynamic measurements to evaluate valvular heart disease, pulmonary hypertension, cardiomyopathy, and other conditions, with the use of coronary angiography at the discretion of the operator. Seventy-five indications were rated as appropriate, 49 were rated as uncertain, and 42 were rated as inappropriate. The appropriate use criteria for diagnostic catheterization have the potential to impact physician decision making, healthcare delivery, and reimbursement policy. Furthermore, recognition of uncertain clinical scenarios facilitates identification of areas that would benefit from future research. © 2012 Wiley Periodicals, Inc. Copyright © 2012 Wiley Periodicals, Inc.
Doppler-guided retrograde catheterization system
NASA Astrophysics Data System (ADS)
Frazin, Leon J.; Vonesh, Michael J.; Chandran, Krishnan B.; Khasho, Fouad; Lanza, George M.; Talano, James V.; McPherson, David D.
1991-05-01
The purpose of this study was to investigate a Doppler guided catheterization system as an adjunctive or alternative methodology to overcome the disadvantages of left heart catheterization and angiography. These disadvantages include the biological effects of radiation and the toxic and volume effects of iodine contrast. Doppler retrograde guidance uses a 20 MHz circular pulsed Doppler crystal incorporated into the tip of a triple lumen multipurpose catheter and is advanced retrogradely using the directional flow information provided by the Doppler waveform. The velocity detection limits are either 1 m/second or 4 m/second depending upon the instrumentation. In a physiologic flow model of the human aortic arch, multiple data points revealed a positive wave form when flow was traveling toward the catheter tip indicating proper alignment for retrograde advancement. There was a negative wave form when flow was traveling away from the catheter tip if the catheter was in a branch or bent upon itself indicating improper catheter tip position for retrograde advancement. In a series of six dogs, the catheter was able to be accurately advanced from the femoral artery to the left ventricular chamber under Doppler signal guidance without the use of x-ray. The potential applications of a Doppler guided retrograde catheterization system include decreasing time requirements and allowing safer catheter guidance in patients with atherosclerotic vascular disease and suspected aortic dissection. The Doppler system may allow left ventricular pressure monitoring in the intensive care unit without the need for x-ray and it may allow left sided contrast echocardiography. With pulse velocity detection limits of 4 m/second, this system may allow catheter direction and passage into the aortic root and left ventricle in patients with aortic stenosis. A modification of the Doppler catheter may include transponder technology which would allow precise catheter tip localization once the catheter tip is placed in the aortic root. Such technology may conceivably assist in allowing selective coronary catheterization. These studies have demonstrated that Doppler guided retrograde catheterization provides an accurate method to catheterization the aortic root and left ventricular chamber without x-ray. In humans, it may prove useful in a variety of settings including the development of invasive ultrasonic diagnostic and therapeutic technology.
Merhi, William M; Turi, Zoltan G; Dixon, Simon; Safian, Robert D
2006-09-01
This report describes the use of a percutaneous ex-vivo femoral arterial bypass in three patients with acute lower extremity ischemia that occurred as a complication of femoral artery catheterization. Utilizing standard equipment and techniques, a percutaneous ex-vivo femoral artery bypass can restore antegrade flow to the ischemic limb in patients with impaired aorto-iliac inflow circulation, which may arise from iatrogenic dissection or the need for large in-dwelling sheaths required for hemodynamic support. This technique is considered a temporizing measure when conventional therapies are not possible. Contrast angiography is recommended to localize and define the cause of limb ischemia, and to permit safe placement of vascular sheaths in the "donor and recipient" arteries.
Manning, James E
2013-08-01
Aortic catheter-based resuscitation therapies are emerging with laboratory investigations showing benefit in models of trauma-related noncompressible torso hemorrhage and nontraumatic cardiac arrest. For these investigational aortic catheter-based therapies to reach their greatest potential clinical benefit, the ability to initiate them in the prehospital setting will be important. Feasibility of prehospital aortic catheterization without imaging capability supports this potential and is described in this report. A physician prehospital response system was created in cooperation with the local emergency medical services system to provide invasive hemodynamic monitoring during cardiac arrest. Physicians were dispatched to all known or suspected prehospital cardiac arrests covered by the emergency medical services system. Physicians responded with a specialized vascular catheterization pack and a monitor with invasive pressure monitoring capability. The physicians performed blind thoracic aortic and central venous catheterizations in cardiac arrest patients in the prehospital setting to measure coronary perfusion pressure, to optimize closed-chest cardiopulmonary resuscitation technique, and to administer intra-aortic epinephrine. During a 2-year period, 22 medical cardiac arrest patients underwent prehospital invasive hemodynamic monitoring to guide resuscitation. Most patients had both aortic and central venous catheters inserted. The combination of intra-aortic epinephrine and adjustments in closed-chest cardiopulmonary resuscitation technique resulted in improved coronary perfusion pressure. Return of spontaneous circulation with survival to hospital admission was achieved in 50% (11 of 22) of these patients. This report demonstrates the feasibility of successful blind aortic and central venous catheterizations in the prehospital environment and supports the potential feasibility of other emerging aortic catheter-based resuscitation therapies.
Younis, Mustafa Z; Jabr, Samer; Smith, Pamela C; Al-Hajeri, Maha; Hartmann, Michael
2011-01-01
Academic research investigating health care costs in the Palestinian region is limited. Therefore, this study examines the costs of the cardiac catheterization unit of one of the largest hospitals in Palestine. We focus on costs of a cardiac catheterization unit and the increasing number of deaths over the past decade in the region due to cardiovascular diseases (CVDs). We employ cost-volume-profit (CVP) analysis to determine the unit's break-even point (BEP), and investigate expected benefits (EBs) of Palestinian government subsidies to the unit. Findings indicate variable costs represent 56 percent of the hospital's total costs. Based on the three functions of the cardiac catheterization unit, results also indicate that the number of patients receiving services exceed the break-even point in each function, despite the unit receiving a government subsidy. Our findings, although based on one hospital, will permit hospital management to realize the importance of unit costs in order to make informed financial decisions. The use of break-even analysis will allow area managers to plan minimum production capacity for the organization. The economic benefits for patients and the government from the unit may encourage government officials to focus efforts on increasing future subsidies to the hospital.
Bladder catheterization in Greek nursing education: An audit of the skills taught.
Theofanidis, Dimitrios; Fountouki, Antigoni
2011-02-01
The auditing of nurse teaching is in its infancy in Greece. One area urgently in need of audit is the teaching of male catheterization. To assess the current educational model regarding male bladder catheterization at a sole tertiary education nursing establishment in a major Greek city and to improve nurse undergraduate training by implementing appropriate recommendations for change to the current educational module and support these changes in the long term. A systematic search of international databases for guidelines or best practice regarding bladder catheterization was conducted. Audit measures included direct observation of the teaching process and compilation of a checklist. The shortcomings are discussed under the following headings: patient pre-preparation, choice and quality of materials used, appropriate aseptic techniques, catheter withdrawal, connecting and handling the drainage bag, diminishing risk of Catheter Associated Urinary Track Infections (CAUTIs), no problem solving trouble-shooting training, textbook and educational resources, lack of national guidelines, setting of the educational experience. The main problem with the teaching process exposed by the audit is entrenched use of an outmoded textbook with little effort to enrich teaching with current evidence base practices. Copyright © 2010 Elsevier Ltd. All rights reserved.
Armstrong, Karen; Dixon, Simon; May, Sara; Patricolo, Gail Elliott
2014-11-01
This study aimed to evaluate the effectiveness of massage with or without guided imagery in reducing anxiety prior to cardiac catheterization. A total of 55 inpatients and outpatients received massage, guided imagery, or massage with guided imagery prior to cardiac catheterization. Self-reported anxiety levels and blood pressure (BP) and heart rate (HR) were evaluated in participants and a matched comparison group. Massage with and without guided imagery resulted in significant reductions in self-reported anxiety (p < 0.0001). Patients receiving intervention had lower diastolic BP and HR vs. the comparison group (p < 0.0001 and p < 0.05). Massage with or without guided imagery immediately reduced self-reported anxiety. This pilot study has certain limitations: a non-randomized, convenience sample and a matched control group that was created retrospectively. However, the study indicates a benefit to providing massage or massage with guided imagery prior to anxiety-inducing medical procedures such as cardiac catheterization. Copyright © 2014 Elsevier Ltd. All rights reserved.
Modified technique for common carotid artery transposition in standing horses.
Tapio, Heidi; Argüelles, David; Gracia-Calvo, Luis A; Raekallio, Marja
2017-01-01
To describe a modified technique for permanent translocation of the common carotid artery (CCA) to a subcutaneous position in standing horses. Experimental study. Healthy adult Standardbred and Warmblood horses (n = 8). Surgery was performed with the horses standing under sedation and with local anesthesia. A combination of previously described techniques was used modifying the approach and closure of the incision. The right CCA was approached through a linear skin incision dorsal and parallel to the jugular vein and through the brachiocephalicus and omohyoideus muscles. The artery was dissected free of its sheath and elevated to the skin incision with Penrose drains. The brachiocephalicus muscle was sutured in two layers underneath the artery leaving it in a subcutaneous position. The horses were allowed to heal for 3 weeks prior to catheterization of the artery. The transposed CCA was successfully used for repeated catheterization in six of eight horses for a period of 10 weeks. None of the horses had intraoperative complications. Two horses developed mild peri-incisional edema that resolved spontaneously. Right-sided laryngeal hemiplegia was observed endoscopically in two horses postoperatively. Two horses developed complications (surgical site infection and excessive periarterial fibrosis) that compromised the patency of the CCA and precluded catheterization. Permanent translocation of the CCA in standing horses was successful in six out of eight horses. Upper airway endoscopy postoperatively may be warranted as laryngeal hemiplegia may ensue. © 2016 The American College of Veterinary Surgeons.
Han, Christopher S; Kim, Sinae; Radadia, Kushan D; Zhao, Philip T; Elsamra, Sammy E; Olweny, Ephrem O; Weiss, Robert E
2017-12-01
We performed a network meta-analysis of available randomized, controlled trials to elucidate the risks of urinary tract infection associated with transurethral catheterization, suprapubic tubes and intermittent catheterization in the postoperative setting. PubMed®, EMBASE® and Google Scholar™ searches were performed for eligible randomized, controlled trials from January 1980 to July 2015 that included patients who underwent transurethral catheterization, suprapubic tube placement or intermittent catheterization at the time of surgery and catheterization lasting up to postoperative day 30. The primary outcome of comparison was the urinary tract infection rate via a network meta-analysis with random effects model using the netmeta package in R 3.2 (www.r-project.org/). Included in analysis were 14 randomized, controlled trials in a total of 1,391 patients. Intermittent catheterization and suprapubic tubes showed no evidence of decreased urinary tract infection rates compared to transurethral catheterization. Suprapubic tubes and intermittent catheterization had comparable urinary tract infection rates (OR 0.903, 95% CI 0.479-2.555). On subgroup analysis of 10 randomized, controlled trials with available mean catheterization duration data in a total of 928 patients intermittent catheterization and suprapubic tube were associated with significantly decreased risk of urinary tract infection compared to transurethral catheterization when catheterization duration was greater than 5 days (OR 0.173, 95% CI 0.073-0.412 and OR 0.142, 95% CI 0.073-0.276, respectively). Transurethral catheterization is not associated with an increased urinary tract infection risk compared to suprapubic tubes and intermittent catheterization if catheterization duration is 5 days or less. However, a suprapubic tube or intermittent catheterization is associated with a lower rate of urinary tract infection if longer term catheterization is expected in the postoperative period. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
The pulmonary artery catheter: a critical reappraisal.
Gidwani, Umesh K; Mohanty, Bibhu; Chatterjee, Kanu
2013-11-01
Balloon floatation pulmonary artery catheters (PACs) have been used for hemodynamic monitoring in cardiac, medical, and surgical intensive care units since the 1970s. With the availability of newer noninvasive diagnostic modalities, particularly echocardiography, the frequency of diagnostic pulmonary artery catheterization has declined. In this review, the evolution of PACs, the results of nonrandomized and randomized studies in various clinical conditions, the uses and abuses of bedside hemodynamic monitoring, and current indications for pulmonary artery catheterization are discussed. Copyright © 2013 Elsevier Inc. All rights reserved.
SHERLOCK 3CG™ Diamond Tip Confirmation System
2018-05-15
Indication for Peripheral Intravenous Catheterization; Atrial Flutter; Premature Atrial Contraction; Premature Ventricular Contraction; Premature Junctional Contraction; Tachycardia; Atrioventricular Block; Bundle-Branch Block
Accurate, noninvasive continuous monitoring of cardiac output by whole-body electrical bioimpedance.
Cotter, Gad; Moshkovitz, Yaron; Kaluski, Edo; Cohen, Amram J; Miller, Hilton; Goor, Daniel; Vered, Zvi
2004-04-01
Cardiac output (CO) is measured but sparingly due to limitations in its measurement technique (ie, right-heart catheterization). Yet, in recent years it has been suggested that CO may be of value in the diagnosis, risk stratification, and treatment titration of cardiac patients, especially those with congestive heart failure (CHF). We examine the use of a new noninvasive, continuous whole-body bioimpedance system (NICaS; NI Medical; Hod-Hasharon, Israel) for measuring CO. The aim of the present study was to test the validity of this noninvasive cardiac output system/monitor (NICO) in a cohort of cardiac patients. Prospective, double-blind comparison of the NICO and thermodilution CO determinations. We enrolled 122 patients in three different groups: during cardiac catheterization (n = 40); before, during, and after coronary bypass surgery (n = 51); and while being treated for acute congestive heart failure (CHF) exacerbation (n = 31). MEASUREMENTS AND INTERVENTION: In all patients, CO measurements were obtained by two independent blinded operators. CO was measured by both techniques three times, and an average was determined for each time point. CO was measured at one time point in patients undergoing coronary catheterization; before, during, and after bypass surgery in patients undergoing coronary bypass surgery; and before and during vasodilator treatment in patients treated for acute heart failure. Overall, 418 paired CO measurements were obtained. The overall correlation between the NICO cardiac index (CI) and the thermodilution CI was r = 0.886, with a small bias (0.0009 +/- 0.684 L) [mean +/- 2 SD], and this finding was consistent within each group of patients. Thermodilution readings were 15% higher than NICO when CI was < 1.5 L/min/m(2), and 5% lower than NICO when CI was > 3 L/min/m(2). The NICO has also accurately detected CI changes during coronary bypass operation and vasodilator administration for acute CHF. The results of the present study indicate that whole-body bioimpedance CO measurements obtained by the NICO are accurate in rapid, noninvasive measurement and the follow-up of CO in a wide range of cardiac clinical situations.
Tsygankov, V N; Varava, A B
2013-01-01
The authors share herein their experience with an antegrade brachial access for treatment of patients presenting with arteriovenous angiodysplasia localizing on the distal portions of the upper limbs, also describing the choice of the site for puncture and the technique of antegrade catheterization of the brachial artery. This is followed by reporting the results of successful use of this access in a total of 27 patients. The access is simple to create, making it possible to easily perform the intervention using instruments of standard length. It is also safe, requires no bed rest in the postoperative period, and is well tolerated by the patients.
Jayaram, Natalie; Spertus, John A; Kennedy, Kevin F; Vincent, Robert; Martin, Gerard R; Curtis, Jeptha P; Nykanen, David; Moore, Phillip M; Bergersen, Lisa
2017-11-21
Risk standardization for adverse events after congenital cardiac catheterization is needed to equitably compare patient outcomes among different hospitals as a foundation for quality improvement. The goal of this project was to develop a risk-standardization methodology to adjust for patient characteristics when comparing major adverse outcomes in the NCDR's (National Cardiovascular Data Registry) IMPACT Registry (Improving Pediatric and Adult Congenital Treatment). Between January 2011 and March 2014, 39 725 consecutive patients within IMPACT undergoing cardiac catheterization were identified. Given the heterogeneity of interventional procedures for congenital heart disease, new procedure-type risk categories were derived with empirical data and expert opinion, as were markers of hemodynamic vulnerability. A multivariable hierarchical logistic regression model to identify patient and procedural characteristics predictive of a major adverse event or death after cardiac catheterization was derived in 70% of the cohort and validated in the remaining 30%. The rate of major adverse event or death was 7.1% and 7.2% in the derivation and validation cohorts, respectively. Six procedure-type risk categories and 6 independent indicators of hemodynamic vulnerability were identified. The final risk adjustment model included procedure-type risk category, number of hemodynamic vulnerability indicators, renal insufficiency, single-ventricle physiology, and coagulation disorder. The model had good discrimination, with a C-statistic of 0.76 and 0.75 in the derivation and validation cohorts, respectively. Model calibration in the validation cohort was excellent, with a slope of 0.97 (standard error, 0.04; P value [for difference from 1] =0.53) and an intercept of 0.007 (standard error, 0.12; P value [for difference from 0] =0.95). The creation of a validated risk-standardization model for adverse outcomes after congenital cardiac catheterization can support reporting of risk-adjusted outcomes in the IMPACT Registry as a foundation for quality improvement. © 2017 American Heart Association, Inc.
Fernández-Ruiz, Mario; Calvo, Beatriz; Vara, Rebeca; Villar, Rocío N; Aguado, José María
2013-10-01
The prevalence and predisposing factors were determined for inappropriate urinary catheterization (UC) among inpatients in medical wards. A cross-sectional study was conducted including all patients aged ≥ 18 years admitted to medical wards in a 1300-bed tertiary-care centre, and who had a urinary catheter in place on the day of the survey. Of 380 patients observed, 46 (12.1%) had a urinary catheter in place. Twelve of them (26.1%) were inappropriately catheterized. The most common indication for inappropriate UC was urine output monitoring in a cooperative, non-critically ill patient. Inappropriateness was associated with increased age, poor functional status, urinary incontinence, dementia, and admission from a long-term care facility. Further educational efforts should be focused on improving catheterization prescribing practices by physicians. Copyright © 2012 Elsevier España, S.L. All rights reserved.
Corticosteroids and fetal intervention interact to alter lung maturation in preterm lambs.
Tabor, B L; Lewis, J F; Ikegami, M; Polk, D; Jobe, A H
1994-04-01
The relationship between cortisol infusion and time of fetal catheterization on postnatal lung function of prematurely delivered lambs was investigated with the hypothesis that the intervention of catheterization would alter fetal responsiveness to the maturational effects of corticosteroids. Fetal catheterization was performed on d 117 or on d 122 of gestation. Cortisol or saline control infusions were begun on d 126, with delivery 60 h later on d 128. The animals were ventilated for 1.25 h after delivery, and compliance, the ventilation efficiency index, labeled albumin leak into and out of the lungs, alveolar and lung saturated phosphatidylcholine and surfactant protein A were measured to evaluate lung performance and biochemical indicators of maturation. Cortisol improved compliance and ventilation efficiency and decreased labeled albumin recovery without changing alveolar saturated phosphatidylcholine or surfactant protein A in the animals catheterized at 122 d relative to 122-d saline-infused animals. However, the animals catheterized at 117 d and infused with saline were as mature as assessed by compliance and ventilation efficiency as the 122-d cortisol-treated animals. The 117-d cortisol-infused animals had significantly augmented lung function relative to either 117-d saline-infused or 122-d cortisol-treated lambs and were the only group that had increased alveolar surfactant protein A and lung saturated phosphatidylcholine pool sizes. This study demonstrates that the response of the fetal lung to a maturational agent such as cortisol is dependent on the history of previous fetal interventions.
Development of a simple, rapid, and robust intrathecal catheterization method in the rat.
Mazur, Curt; Fitzsimmons, Bethany; Kamme, Fredrik; Nichols, Brandon; Powers, Berit; Wancewicz, Ed
2017-03-15
The blood brain barrier (BBB) is an impediment to the development of large and highly charged molecules as therapeutics for diseases and injuries of the central nervous system (CNS). Antisense oligonucleotides (ASOs) are large (6000-8000MW) and highly charged and therefore do not cross the BBB. A method of circumventing the blood brain barrier to test ASOs, and other non-BBB penetrant molecules, as CNS therapeutics is the direct administration of these molecules to the CNS tissue or cerebral spinal fluid. We developed a rapid, simple and robust method for the intrathecal catheterization of rats to test putatively therapeutic antisense oligonucleotides. This method utilizes 23-gauge needles, simply constructed ½in. long 19-gauge guide cannulas and 8cm long plastic PE-10 sized catheters. Unlike the cisterna magna approach, this method uses a lumbar approach for intrathecal catheterization with the catheter residing entirely in the cauda equina space minimizing spinal cord compression. Readily available materials and only a few specialized pieces of equipment, which are easily manufactured, are used for this intrathecal catheterization method. This method is easy to learn and has been taught to multiple in house surgeons, collaborators and contract laboratories. Greater than 90% catheterization success is routinely achieved with this method and as many as 100 catheters can be placed and test substance administered in one 6-h period. This method has allowed the pre-clinical testing of hundreds of ASOs as therapeutics for CNS indications. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holmes, D.R. Jr.; Wondrow, M.A.; Gray, J.E.
1990-01-01
The increased application of therapeutic interventional cardiology procedures is associated with increased radiation exposure to physicians, patients and technical personnel. New advances in imaging techniques have the potential for reducing radiation exposure. A progressive scanning video system with a standard vascular phantom has been shown to decrease entrance radiation exposure. The effect of this system on reducing actual radiation exposure to physicians and technicians was assessed from 1984 through 1987. During this time, progressive fluoroscopy was added sequentially to all four adult catheterization laboratories; no changes in shielding procedures were made. During this time, the case load per physician increasedmore » by 63% and the number of percutaneous transluminal coronary angioplasty procedures (a high radiation procedure) increased by 244%. Despite these increases in both case load and higher radiation procedures, the average radiation exposure per physician declined by 37%. During the same time, the radiation exposure for technicians decreased by 35%. Pulsed progressive fluoroscopy is effective for reducing radiation exposure to catheterization laboratory physicians and technical staff.« less
Schroeder, Alan R; Newman, Thomas B; Wasserman, Richard C; Finch, Stacia A; Pantell, Robert H
2005-10-01
The optimal method of urine collection in febrile infants is debatable; catheterization, considered more accurate, is technically difficult and invasive. To determine predictors of urethral catheterization in febrile infants and to compare bag and catheterized urine test performance characteristics. Prospective analysis of infants enrolled in the Pediatric Research in Office Settings' Febrile Infant Study. A total of 219 practices from within the Pediatric Research in Office Settings' network, including 44 states, the District of Columbia, and Puerto Rico. A total of 3066 infants aged 0 to 3 months with temperatures of 38 degrees C or higher. We calculated adjusted odds ratios for predictors of catheterization. Diagnostic test characteristics were compared between bag and catheterization. Urinary tract infection was defined as pure growth of 100 000 CFU/mL or more (bag) and 20 000 CFU/mL or more (catheterization). Seventy percent of urine samples were obtained by catheterization. Predictors of catheterization included female sex, practitioner older than 40 years, Medicaid, Hispanic ethnicity, nighttime evaluation, and severe dehydration. For leukocyte esterase levels, bag specimens demonstrated no difference in sensitivity but somewhat lower specificity (84% [bag] vs 94% [catheterization], P<.001) and a lower area under the receiver operating characteristic curve for white blood cells (0.71 [bag] vs 0.86 [catheterization], P = .01). Infection rates were similar in bag and catheterized specimens (8.5% vs 10.8%). Ambiguous cultures were more common in bag specimens (7.4% vs 2.7%, P<.001), but 21 catheterized specimens are needed to avoid each ambiguous bag result. Most practitioners obtain urine from febrile infants via catheterization, but choice of method is not related to the risk of urinary tract infection. Although both urine cultures and urinalyses are more accurate in catheterized specimens, the magnitude of difference is small but should be factored into clinical decision making.
A Life-Threatening Mediastinal Hematoma After Central Venous Port System Implantation
Sarach, Janine; Zschokke, Irin; Melcher, Gian A.
2015-01-01
Patient: Female, 68 Final Diagnosis: Mediastinal hematoma Symptoms: Agitation • severe hemodynamic instability • severe respiratory distress Medication: — Clinical Procedure: Cardiopulmonary resuscitation • reintubation • thoracic drain Specialty: Surgery Objective: Diagnostic/therapeutic accidents Background: We report a case of surgical central venous port system implantation using Seldinger’s technique with a life-threatening mediastinal hematoma due to the perforation of the superior vena cava. Case Report: A 68-year-old woman was admitted to our institution for port implantation. Open access to the cephalic vein and 2 punctures of the right subclavian vein were unsuccessful. Finally, the port catheter could be placed into the superior vena cava using Seldinger’s technique. As blood aspiration via the port catheter was not possible, fluoroscopy was performed, revealing mediastinal contrast extravasation without contrasting the venous system. A new port system could be placed in the correct position without difficulties. After extubation, the patient presented with severe respiratory distress and required consecutive cardiopulmonary resuscitation and reintubation. The CT scan showed a significant hematoma in the lower neck and posterior mediastinum with tracheal compression. We assumed a perforation of the superior vena cava with the tip of the guidewire using Seldinger’s technique. Long-term intensive treatment with prolonged ventilation and tracheotomy was necessary. The port system had to be subsequently explanted due to infection. Conclusions: Mediastinal hematoma is a rare but life-threatening complication associated with central venous catheterization using Seldinger’s technique. Perforation occurs most often during central venous catheterization in critical care. Mediastinal hematoma is an example of a mechanical complication occurring after central venous catheterization, which has been described only a few times in the literature to date. This case highlights the importance of awareness of possible, rare, life-threatening complications during port implantation, mostly performed in multimorbid patients by surgeons in training. PMID:26703924
Chaudhry-Waterman, Nadia; Coombs, Sandra; Porras, Diego; Holzer, Ralf; Bergersen, Lisa
2014-01-01
The broad range of relatively rare procedures performed in pediatric cardiac catheterization laboratories has made the standardization of care and risk assessment in the field statistically quite problematic. However, with the growing number of patients who undergo cardiac catheterization, it has become imperative that the cardiology community overcomes these challenges to study patient outcomes. The Congenital Cardiac Catheterization Project on Outcomes was able to develop benchmarks, tools for measurement, and risk adjustment methods while exploring procedural efficacy. Based on the success of these efforts, the collaborative is pursuing a follow-up project, the Congenital Cardiac Catheterization Project on Outcomes-Quality Improvement, aimed at improving the outcomes for all patients undergoing catheterization for congenital heart disease by reducing radiation exposure.
Yang, Justin Cheng-Ta; Lin, Ming-Tai; Jaw, Fu-Shan; Chen, Shyh-Jye; Wang, Jou-Kou; Shih, Tiffany Ting-Fang; Wu, Mei-Hwan; Li, Yiu-Wah
2015-11-01
Pediatric cardiac computed tomography (CT) is a noninvasive imaging modality used to clearly demonstrate the anatomical detail of congenital heart diseases. We investigated the impact of cardiac CT on the utilization of cardiac catheterization among children with congenital heart disease. The study sample consisted of 2648 cardiac CT and 3814 cardiac catheterization from 1999 to 2009 for congenital heart diseases. Diagnoses were categorized into 11 disease groups. The numbers of examination, according to the different modalities, were compared using temporal trend analyses. The estimated effective radiation doses (mSv) of CT and catheterization were calculated and compared. The number of CT scans and interventional catheterizations had a slight annual increase of 1.2% and 2.7%, respectively, whereas that of diagnostic catheterization decreased by 6.2% per year. Disease groups fell into two categories according to utilization trend differences between CT and diagnostic catheterization. The increased use of CT reduces the need for diagnostic catheterization in patients with atrioventricular connection disorder, coronary arterial disorder, great vessel disorder, septal disorder, tetralogy of Fallot, and ventriculoarterial connection disorder. Clinicians choose either catheterization or CT, or both examinations, depending on clinical conditions, in patients with semilunar valvular disorder, heterotaxy, myocardial disorder, pericardial disorder, and pulmonary vein disorder. The radiation dose of CT was lower than that of diagnostic cardiac catheterization in all age groups. The use of noninvasive CT in children with selected heart conditions might reduce the use of diagnostic cardiac catheterization. This may release time and facilities within the catheterization laboratory to meet the increasing demand for cardiac interventions. Copyright © 2014. Published by Elsevier B.V.
Two-micron (Thulium) Laser Prostatectomy: An Effective Method for BPH Treatment.
Jiang, Qi; Xia, Shujie
2014-01-01
The two-micron (thulium) laser is the newest laser technique for treatment of bladder outlet obstruction resulting from benign prostatic hyperplasia (BPH). It takes less operative time than standard techniques, provides clear vision and lower blood loss as well as shorter catheterization times and hospitalization times. It has been identified to be a safe and efficient method for BPH treatment regardless of the prostate size.
Portable bladder ultrasound: an evidence-based analysis.
2006-01-01
The aim of this review was to assess the clinical utility of portable bladder ultrasound. TARGET POPULATION AND CONDITION Data from the National Population Health Survey indicate prevalence rates of urinary incontinence are 2.5% in women and 1.4 % in men in the general population. Prevalence of urinary incontinence is higher in women than men and prevalence increases with age. Identified risk factors for urinary incontinence include female gender, increasing age, urinary tract infections (UTI), poor mobility, dementia, smoking, obesity, consuming alcohol and caffeine beverages, physical activity, pregnancy, childbirth, forceps and vacuum-assisted births, episiotomy, abdominal resection for colorectal cancer, and hormone replacement therapy. For the purposes of this review, incontinence populations will be stratified into the following; the elderly, urology patients, postoperative patients, rehabilitation settings, and neurogenic bladder populations. Urinary incontinence is defined as any involuntary leakage of urine. Incontinence can be classified into diagnostic clinical types that are useful in planning evaluation and treatment. The major types of incontinence are stress (physical exertion), urge (overactive bladder), mixed (combined urge and stress urinary incontinence), reflex (neurological impairment of the central nervous system), overflow (leakage due to full bladder), continuous (urinary tract abnormalities), congenital incontinence, and transient incontinence (temporary incontinence). Postvoid residual (PVR) urine volume, which is the amount of urine in the bladder immediately after urination, represents an important component in continence assessment and bladder management to provide quantitative feedback to the patient and continence care team regarding the effectiveness of the voiding technique. Although there is no standardized definition of normal PVR urine volume, measurements greater than 100 mL to 150 mL are considered an indication for urinary retention, requiring intermittent catheterization, whereas a PVR urine volume of 100 mL to 150 mL or less is generally considered an acceptable result of bladder training. Urinary retention has been associated with poor outcomes including UTI, bladder overdistension, and higher hospital mortality rates. The standard method of determining PVR urine volumes is intermittent catheterization, which is associated with increased risk of UTI, urethral trauma and discomfort. Portable bladder ultrasound products are transportable ultrasound devices that use automated technology to register bladder volume digitally, including PVR volume, and provide three-dimensional images of the bladder. The main clinical use of portable bladder ultrasound is as a diagnostic aid. Health care professionals (primarily nurses) administer the device to measure PVR volume and prevent unnecessary catheterization. An adjunctive use of the bladder ultrasound device is to visualize the placement and removal of catheters. Also, portable bladder ultrasound products may improve the diagnosis and differentiation of urological problems and their management and treatment, including the establishment of voiding schedules, study of bladder biofeedback, fewer UTIs, and monitoring of potential urinary incontinence after surgery or trauma. To determine the effectiveness and clinical utility of portable bladder ultrasound as reported in the published literature, the Medical Advisory Secretariat used its standard search strategy to retrieve international health technology assessments and English-language journal articles from selected databases. Nonsystematic reviews, nonhuman studies, case reports, letters, editorials, and comments were excluded. Of the 4 included studies that examined the clinical utility of portable bladder ultrasound in the elderly population, all found the device to be acceptable. One study reported that the device underestimated catheterized bladder volume In patients with urology problems, 2 of the 3 studies concerning portable bladder ultrasound found the device acceptable to use. However, one study did not find the device as accurate for small PVR volume as for catheterization and another found that the device overestimated catheterized bladder volume. In the remaining study, the authors reported that when the device's hand-held ultrasound transducers (scanheads) were aimed improperly, bladders were missed, or lateral borders of bladders were missed resulting in partial bladder volume measurements and underestimation of PVR measurements. They concluded that caution should be used in interpreting PVR volume measured by portable bladder ultrasound machines and that catheterization may be the preferred assessment modality if an accurate PVR measurement is necessary. All 3 studies with post-operative populations found portable bladder ultrasound use to be reasonably acceptable. Two studies reported that the device overestimated catheter-derived bladder volumes, one by 7% and the other by 21 mL. The third study reported the opposite, that the device underestimated catheter bladder volume by 39 mL but that the results remained acceptable In rehabilitation settings, 2 studies found portable bladder ultrasound to underestimate catheter-derived bladder volumes; yet, both authors concluded that the mean errors were within acceptable limits. In patients with neurogenic bladder problems, 2 studies found portable bladder ultrasound to be an acceptable alternative to catheterization despite the fact that it was not as accurate as catheterization for obtaining bladder volumes. Lastly, examinations concerning avoidance of negative health outcomes showed that, after use of the portable bladder ultrasound, unnecessary catheterizations and UTIs were decreased. Unnecessary catheterizations avoided ranged from 16% to 47% in the selected articles. Reductions in UTI ranged from 38% to 72%. In sum, all but one study advocated the use of portable bladder ultrasound as an alternative to catheterization. An economic analysis estimating the budget-impact of BladderScan in complex continuing care facilities was completed. The analysis results indicated a $192,499 (Cdn) cost-savings per year per facility and a cost-savings of $2,887,485 (Cdn) for all 15 CCC facilities. No economic analysis was completed for long-term care and acute care facilities due to lack of data. Rapid diffusion of portable bladder ultrasound technology is expected. Recently, the IC5 project on improving continence care in Ontario's complex continuing care centres piloted portable bladder ultrasound at 12 sites. Preliminary results were promising. Many physicians and health care facilities already have portable bladder ultrasound devices. However, portable bladder ultrasound devices for PVR measurement are not in use at most health care facilities in Ontario and Canada. The Verathon Corporation (Bothell, Wisconsin, United States), which patents BladderScan, is the sole licensed manufacturer of the portable bladder ultrasound in Canada. Field monopoly may influence the rising costs of portable bladder ultrasound, particularly when faced with rapid expansion of the technology. Several thousand residents of Ontario would benefit from portable bladder ultrasound. The number of residents of Ontario that would benefit from the technology is difficult to quantify, because the incidence and prevalence of incontinence are grossly under-reported. However, long-term care and complex continuing care institutions would benefit greatly from portable bladder ultrasound, as would numerous rehabilitation units, postsurgical care units, and urology clinics. The cost of the portable bladder ultrasound devices ranges from $17,698.90 to $19,565.95 (Cdn) (total purchase price per unit as quoted by the manufacturer). Additional training packages, batteries and battery chargers, software, gel pads, and yearly warranties are additional costs. Studies indicate that portable bladder ultrasound is a cost-effective technology, because it avoids costs associated with catheterization equipment, saves nursing time, and reduces catheter-related complications and UTIs. The use of portable bladder ultrasound device will affect the patient directly in terms of health outcomes. Its use avoids the trauma related to the urinary tract that catheterization inflicts, and does not result in UTIs. In addition, patients prefer it, because it preserves dignity and reduces discomfort.
2006-01-01
Executive Summary Objective The aim of this review was to assess the clinical utility of portable bladder ultrasound. Clinical Need: Target Population and Condition Data from the National Population Health Survey indicate prevalence rates of urinary incontinence are 2.5% in women and 1.4 % in men in the general population. Prevalence of urinary incontinence is higher in women than men and prevalence increases with age. Identified risk factors for urinary incontinence include female gender, increasing age, urinary tract infections (UTI), poor mobility, dementia, smoking, obesity, consuming alcohol and caffeine beverages, physical activity, pregnancy, childbirth, forceps and vacuum-assisted births, episiotomy, abdominal resection for colorectal cancer, and hormone replacement therapy. For the purposes of this review, incontinence populations will be stratified into the following; the elderly, urology patients, postoperative patients, rehabilitation settings, and neurogenic bladder populations. Urinary incontinence is defined as any involuntary leakage of urine. Incontinence can be classified into diagnostic clinical types that are useful in planning evaluation and treatment. The major types of incontinence are stress (physical exertion), urge (overactive bladder), mixed (combined urge and stress urinary incontinence), reflex (neurological impairment of the central nervous system), overflow (leakage due to full bladder), continuous (urinary tract abnormalities), congenital incontinence, and transient incontinence (temporary incontinence). Postvoid residual (PVR) urine volume, which is the amount of urine in the bladder immediately after urination, represents an important component in continence assessment and bladder management to provide quantitative feedback to the patient and continence care team regarding the effectiveness of the voiding technique. Although there is no standardized definition of normal PVR urine volume, measurements greater than 100 mL to 150 mL are considered an indication for urinary retention, requiring intermittent catheterization, whereas a PVR urine volume of 100 mL to 150 mL or less is generally considered an acceptable result of bladder training. Urinary retention has been associated with poor outcomes including UTI, bladder overdistension, and higher hospital mortality rates. The standard method of determining PVR urine volumes is intermittent catheterization, which is associated with increased risk of UTI, urethral trauma and discomfort. The Technology Being Reviewed Portable bladder ultrasound products are transportable ultrasound devices that use automated technology to register bladder volume digitally, including PVR volume, and provide three-dimensional images of the bladder. The main clinical use of portable bladder ultrasound is as a diagnostic aid. Health care professionals (primarily nurses) administer the device to measure PVR volume and prevent unnecessary catheterization. An adjunctive use of the bladder ultrasound device is to visualize the placement and removal of catheters. Also, portable bladder ultrasound products may improve the diagnosis and differentiation of urological problems and their management and treatment, including the establishment of voiding schedules, study of bladder biofeedback, fewer UTIs, and monitoring of potential urinary incontinence after surgery or trauma. Review Strategy To determine the effectiveness and clinical utility of portable bladder ultrasound as reported in the published literature, the Medical Advisory Secretariat used its standard search strategy to retrieve international health technology assessments and English-language journal articles from selected databases. Nonsystematic reviews, nonhuman studies, case reports, letters, editorials, and comments were excluded. Summary of Findings Of the 4 included studies that examined the clinical utility of portable bladder ultrasound in the elderly population, all found the device to be acceptable. One study reported that the device underestimated catheterized bladder volume In patients with urology problems, 2 of the 3 studies concerning portable bladder ultrasound found the device acceptable to use. However, one study did not find the device as accurate for small PVR volume as for catheterization and another found that the device overestimated catheterized bladder volume. In the remaining study, the authors reported that when the device’s hand-held ultrasound transducers (scanheads) were aimed improperly, bladders were missed, or lateral borders of bladders were missed resulting in partial bladder volume measurements and underestimation of PVR measurements. They concluded that caution should be used in interpreting PVR volume measured by portable bladder ultrasound machines and that catheterization may be the preferred assessment modality if an accurate PVR measurement is necessary. All 3 studies with post-operative populations found portable bladder ultrasound use to be reasonably acceptable. Two studies reported that the device overestimated catheter-derived bladder volumes, one by 7% and the other by 21 mL. The third study reported the opposite, that the device underestimated catheter bladder volume by 39 mL but that the results remained acceptable In rehabilitation settings, 2 studies found portable bladder ultrasound to underestimate catheter-derived bladder volumes; yet, both authors concluded that the mean errors were within acceptable limits. In patients with neurogenic bladder problems, 2 studies found portable bladder ultrasound to be an acceptable alternative to catheterization despite the fact that it was not as accurate as catheterization for obtaining bladder volumes. Lastly, examinations concerning avoidance of negative health outcomes showed that, after use of the portable bladder ultrasound, unnecessary catheterizations and UTIs were decreased. Unnecessary catheterizations avoided ranged from 16% to 47% in the selected articles. Reductions in UTI ranged from 38% to 72%. In sum, all but one study advocated the use of portable bladder ultrasound as an alternative to catheterization. Economic Analysis An economic analysis estimating the budget-impact of BladderScan in complex continuing care facilities was completed. The analysis results indicated a $192,499 (Cdn) cost-savings per year per facility and a cost-savings of $2,887,485 (Cdn) for all 15 CCC facilities. No economic analysis was completed for long-term care and acute care facilities due to lack of data. Considerations for Policy Development Rapid diffusion of portable bladder ultrasound technology is expected. Recently, the IC5 project on improving continence care in Ontario’s complex continuing care centres piloted portable bladder ultrasound at 12 sites. Preliminary results were promising. Many physicians and health care facilities already have portable bladder ultrasound devices. However, portable bladder ultrasound devices for PVR measurement are not in use at most health care facilities in Ontario and Canada. The Verathon Corporation (Bothell, Wisconsin, United States), which patents BladderScan, is the sole licensed manufacturer of the portable bladder ultrasound in Canada. Field monopoly may influence the rising costs of portable bladder ultrasound, particularly when faced with rapid expansion of the technology. Several thousand residents of Ontario would benefit from portable bladder ultrasound. The number of residents of Ontario that would benefit from the technology is difficult to quantify, because the incidence and prevalence of incontinence are grossly under-reported. However, long-term care and complex continuing care institutions would benefit greatly from portable bladder ultrasound, as would numerous rehabilitation units, postsurgical care units, and urology clinics. The cost of the portable bladder ultrasound devices ranges from $17,698.90 to $19,565.95 (Cdn) (total purchase price per unit as quoted by the manufacturer). Additional training packages, batteries and battery chargers, software, gel pads, and yearly warranties are additional costs. Studies indicate that portable bladder ultrasound is a cost-effective technology, because it avoids costs associated with catheterization equipment, saves nursing time, and reduces catheter-related complications and UTIs. The use of portable bladder ultrasound device will affect the patient directly in terms of health outcomes. Its use avoids the trauma related to the urinary tract that catheterization inflicts, and does not result in UTIs. In addition, patients prefer it, because it preserves dignity and reduces discomfort. PMID:23074481
Pandey, R; Ashraf, H; Bhalla, A P; Garg, R
2012-01-01
Optimal wrist position is essential for successful catheterization of the radial artery. We planned to study the success rate of radial artery catheterization at various degrees of wrist extension angulations. This prospective, randomized study was performed in 60 consenting patients aged between 18-65 years and undergoing variable surgeries where the anesthetic management required an arterial catheterization. All patients were randomized into three groups of 20 patients each, according to wrist angulation during radial artery catheterization : either 30 degrees (Group 30), 45 degrees (Group 45), or 60 degrees (Group 60). Three metallic angulated wrist boards with angles of 30 degrees, 45 degrees, and 60 degrees (angle measured with calipers) were prepared, on which patient's wrist was kept at the above-mentioned angles of extension. Radial artery catheterization success rate, catheterization time, and numbers of attempts were recorded. The catheterization time was minimal in group 45 (30.50 +/- 16.82 sec) as compared to 36.00 +/- 14.19 sec and 43.50 +/- 13.80 sec in group 30 and 60, respectively. Radial artery was catheterized at first attempt in 60% of Group 45 and Group 60 patients, and in 50% of Group 30 patients. The arterial catheterization was successful in 14/20 patients in Group 30, 19/20 patients in group 45, and 16/20 patients in group 60. We conclude that a wrist extension of 450 appears to be the optimal wrist joint extension for a successful radial artery cannula insertion.
PREVALENCE OF POST-THROMBOTIC SYNDROME AFTER CARDIAC CATHETERIZATION
Luceri, Michael J.; Tala, Joana A.; Weismann, Constance G.; Silva, Cicero T.; Faustino, E. Vincent S.
2015-01-01
BACKGROUND As the survival of children with cardiac disease increases, chronic complications of deep venous thrombosis from cardiac catheterization, particularly post-thrombotic syndrome, may be important to monitor for and treat, if needed. We aimed to determine the prevalence of this syndrome in children who underwent cardiac catheterization. PROCEDURE We conducted a cross-sectional study of children <18 years old at least 1 year from first catheterization through the femoral vein. We used the Manco-Johnson instrument, the only tool validated in children, to diagnose post-thrombotic syndrome. We defined the syndrome as a score ≥1. It was considered physically and functionally significant if the score was ≥1 in both physical and functional domains of the instrument. We also conducted ultrasonography to assess for thrombosis and valvular insufficiency. RESULTS We enrolled 62 children with a median age of 4 months during catheterization and a median of 5.4 years since catheterization. A total of 40 children had post-thrombotic syndrome (prevalence: 64.5%; 95% confidence interval: 51.3%–76.3%), the majority of which were mild. Presence of cyanotic congenital heart disease, total number of catheterizations, use of antithrombotic agents at any time after the first catheterization, age at first catheterization, or time since first catheterization was not associated with the syndrome. A total of 7 children (prevalence: 11.3%; 95% confidence interval: 3.2%–19.4%) had physically and functionally significant syndrome. None of the children had abnormalities on ultrasonography at the time of enrollment. CONCLUSIONS Post-thrombotic syndrome is a common complication after cardiac catheterization. Manifestations are usually mild and unlikely to require treatment. PMID:25663038
Iatrogenic vertebral artery pseudoaneurysm due to central venous catheterization
Vasquez, Jay
2011-01-01
Central venous lines have become an integral part of patient care, but they are not without complications. Vertebral artery pseudoaneurysm formation is one of the rarer complications of central line placement. Presented is a rare case of two pseudoaneurysms of the vertebral and subclavian artery after an attempted internal jugular vein catheterization. These were successfully treated with open surgical repair and bypass. Open surgical repair remains the gold standard of treatment. Endovascular repair of vertebral artery pseudoaneurysms has been described with promising outcomes, but long-term results are lacking. Ultimately, the best treatment of these iatrogenic injuries should start with prevention. Well-documented techniques to minimize mechanical complications, including inadvertent arterial puncture, should be practiced and taught in training programs to avoid the potentially devastating consequences. PMID:21566753
Agrawal, Hitesh; Molossi, Silvana; Alam, Mahboob; Sexson-Tejtel, S Kristen; Mery, Carlos M; McKenzie, E Dean; Fraser, Charles D; Qureshi, Athar M
2017-03-01
The evaluation of the vast majority of children with anomalous aortic origin of a coronary artery (AAOCA) and/or myocardial bridges is performed with non-invasive testing. However, a subset of these patients may benefit from invasive testing for risk stratification. All patients included in the Coronary Anomalies Program (CAP) at Texas Children's Hospital who underwent cardiac catheterization were included. Techniques included selective coronary angiograms (SCA), intravascular ultrasound (IVUS), and fractional flow reserve (FFR) measurements with provocative testing using adenosine and/or dobutamine infusions. Out of the 131 patients followed by the CAP between 12/12-4/16, 8 (6%) patients underwent 9 cath investigations at median age 13.1 (2.6-18.7) years and median weight 49.5 (11.4-142.7) kg. Six patients presented with cardiac signs/symptoms. Four patients had myocardial bridges of the left anterior descending (LAD) coronary artery, 2 patients had isolated AAOCA, and 2 patients had an anomalous left coronary artery (LCA) with an intramyocardial course of the LAD. SCA was performed in all patients. FFR was positive in 4/6 patients: IVUS showed >70% intraluminal narrowing in 3/5 patients. One patient had hemodynamic instability that reversed with catheter removal from the coronary ostium. Based on the catheterization data obtained, findings were reassuring in three patients, surgery was performed in three patients, and two patients are being medically managed/restricted from competitive sports. In our small cohort of patients, we demonstrated that IVUS and FFR can safely be performed in children and may help to risk stratify some patients with AAOCA and myocardial bridges.
Carol Ruiz, Antoni; Masip Utset, Josep; Ariza Solé, Albert
2017-03-01
The benefit of primary angioplasty may be reduced if there are delays to reperfusion. Identification of the variables associated with these delays could improve health care. Analysis of the Codi Infart registry of Catalonia and of the time to angioplasty depending on the place of first medical contact. In 3832 patients analyzed, first medical contact took place in primary care centers in 18% and in hospitals without a catheterization laboratory in 37%. Delays were longer in these 2 groups than in patients attended by the outpatient emergency medical system or by hospitals with a catheterization laboratory (P < .0001, results in median): first medical contact to reperfusion indication time was 42minutes in both (overall 35minutes); first medical contact to artery opening time was 131 and 143minutes, respectively (overall 121minutes); total ischemia time was 230 and 260minutes (overall 215minutes). First medical contact to artery opening time > 120minutes was strongly associated with first medical contact in a center without a catheterization laboratory (OR, 4.96; 95% confidence interval, 4.14-5.93), and other factors such as age, previous coronary surgery, first medical contact during evening hours, nondiagnostic electrocardiogram, and Killip class ≥ III. Mortality at 30 days and 1 year was 5.6% and 8.7% and was independently associated with age, longer delay to angioplasty, Killip class ≥ II, and first medical contact in a center with a catheterization laboratory. In more than 50% of patients requiring primary angioplasty, the first medical contact occurs in centers without a catheterization laboratory, which is an important predictor of delay from diagnosis to artery opening. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Robot-assisted technique for boari flap ureteral reimplantation: is robot assistance beneficial?
Do, Minh; Kallidonis, Panagiotis; Qazi, Hasan; Liatsikos, Evangelos; Ho Thi, Phuc; Dietel, Anja; Stolzenburg, Jens-Uwe
2014-06-01
Ureteral reconstructive surgery necessitates adequate exposure of the ureteral lesion and results in large abdominal incisions. Robot assistance allows the performance of complex ureteral reconstructive surgery through small incisions. The current series includes only cases of Boari flaps performed by robot assistance and attempts to describe in detail the technique, review the literature, as well as to expand the experience in the current literature. Eight patients underwent ureteral reimplantation by Boari flap technique. The indications for the performance of the procedure included ureteral stricture from iatrogenic injury in three patients, recurrent ureteral stricture after multiple endoscopic stone management procedures in one patient, ureteral stricture from previous malignant disease in the pelvis or abdomen in three patients, and ureteral stricture due to trauma in one patient. Five cases were located in the left side and three cases in the right side. A variety of parameters were recorded in a prospective database including the time for robot docking and total operative time as well as catheterization and drainage time. The follow-up of the patients included the performance of renal ultrasonography 4 weeks, 3, 6, and 12 months after the procedure. Mean age of the patients was 50.8 (range 39-62) years and mean body mass index was 26.2 (range 23.22-29.29) kg/m(2). Operative time ranged 115 and 240 (mean 171.9) minutes. Mean blood loss was 161.3 (50-250) mL. Conversion to open surgery did not take place in the current series. No intraoperative complications were observed. Postoperative complications included one case of prolonged anastomotic leakage. The robot-assisted approach is efficient in the performance of ureteral reimplantation with Boari flap. Low blood loss, short catheterization time, low complication rate, and excellent reconstructive outcome are associated with the approach. Robot assistance seems to be beneficial for ureteral reconstructive surgery.
[ERCP success after 72 hours of pre-cut].
Peñaloza-Ramírez, Arecio; Murillo-Arias, Andrés; Rodríguez-Mongui, Jaison; Carvajal-Flechas, Ricardo; Aponte-Ordoñez, Pedro
2018-01-01
Despite the advances of bile duct catheterization, its success is still not guaranteed. Few studies have been published regarding a second ERCP attempt, however those reports enhance the catheterization success Objective: To determine whether an ERCP performed 72 hours after a first precut papillotomy enhances the bile duct catheterization. A cohort study was performed including all patients that had ERCP with precut papilotomy without catheterization of the bile duct and 72 hours later were programmed to a new ERCP between September 2015 and September 2016. These patients did not have any distinctive characteristic such as age, gender or anatomy that were associated with the failure to catheterize the bile duct, compared to the general population. 16 patients were included with a mean age of 61,3 years (SD: 10,6), bile duct catheterization was successful in 14 cases. No complications presented after precut papilotomy. Both failures went to surgery. Our experience about an 87% successful bile duct catheterization, 72 hours after precut papillotomy allows us to suggest it as an alternative before considering surgery.
Anesthesia and the pediatric cardiac catheterization suite: a review.
Lam, Jennifer E; Lin, Erica P; Alexy, Ryan; Aronson, Lori A
2015-02-01
Advances in technology over the last couple of decades have caused a shift in pediatric cardiac catheterization from a primary focus on diagnostics to innovative therapeutic interventions. These improvements allow patients a wider range of nonsurgical options for treatment of congenital heart disease. However, these therapeutic modalities can entail higher risk in an already complex patient population, compounded by the added challenges inherent to the environment of the cardiac catheterization suite. Anesthesiologists caring for children with congenital heart disease must understand not only the pathophysiology of the disease but also the effects the anesthetics and interventions have on the patient in order to provide a safe perioperative course. It is the aim of this article to review the latest catheterization modalities offered to patients with congenital heart disease, describe the unique challenges presented in the cardiac catheterization suite, list the most common complications encountered during catheterization and finally, to review the literature regarding different anesthetic drugs used in the catheterization lab. © 2014 John Wiley & Sons Ltd.
Uncommon incidental pseudoaneurysm. Diagnostic and management challenges.
Hadidy, Azmy M; Samara, Osama A; Takrouri, Heba S; Al-Ryalat, Nosaiba T; Al-Smady, Moaath M; Ryalat, Soukaina T; Abu-Khalaf, Mahmoad M
2009-08-01
To analyze patients with uncommon incidental pseudoaneurysms, secondary to non-catheterization causes, and to discuss the peculiar clinical spectrum, and focus on some aspects of difference from post-catheterization pseudoaneurysms. Eleven patients, 8 males and 3 females, were studied retrospectively in Jordan University Hospital, Amman, Jordan, between 2002-2008. Radiological studies performed included duplex sonography (DS), computed tomography (CT), conventional angiography, magnetic resonance imaging (MRI), and magnetic resonance angiography (MRA). Pseudoaneurysms were most commonly encountered in young males (63.6%), especially in the lower limb vessels (36%). Clinical findings were suggestive of pseudoaneurysms in 27% of our cases. Four out of the 8 DS scans showed the neck of pseudoaneurysms, and the to and fro waveform, the strongest indicators for pseudoaneurysms. Both CT with intravenous contrast and angiography failed to establish the diagnosis in one out of 5 cases. The MRI with MRA showed the pseudoaneurysms in 2 patients that underwent the scan. Incidental pseudoaneurysms are considered following iatrogenic procedures, penetrating, or blunt traumas with variable delay time. Young healthy males are at increased risks, as opposed to elderly females with calcified vessels in post-catheterization cases. Duplex sonography is less sensitive in incidental than post-catheterization pseudoaneurysms. The CT scan with intravenous contrast has high accuracy in establishing the diagnosis in small, or medium sized pseudoaneurysms. The MRI and MRA are accurate valuable studies and comparable to conventional angiography.
Kwon, Hyun-Jung; Jeong, Young-Il; Jun, In-Gu; Moon, Young-Jin; Lee, Yu-Mi
2018-01-01
Abstract Subclavian central venous catheterization is a common procedure for which misplacement of the central venous catheter (CVC) is a frequent complication that can potentially be fatal. The carina is located in the mid-zone of the superior vena cava (SVC) and is considered a reliable landmark for CVC placement in chest radiographs. The C-length, defined as the distance from the edge of the right transverse process of the first thoracic spine to the carina, can be measured in posteroanterior chest radiographs using a picture archiving and communication system. To evaluate the placement of the tip of the CVC in subclavian central venous catheterizations using the C-length, we reviewed the medical records and chest radiographs of 122 adult patients in whom CVC catheterization was performed (from January 2012 to December 2014) via the right subclavian vein using the C-length. The tips of all subclavian CVCs were placed in the SVC using the C-length. No subclavian CVC entered the right atrium. Tip placement was not affected by demographic characteristics such as age, sex, height, weight, and body mass index. The evidence indicates that the C-length on chest radiographs can be used to determine the available insertion length and place the right subclavian CVC tip into the SVC. PMID:29480861
Swan-Ganz - right heart catheterization
... this page: //medlineplus.gov/ency/article/003870.htm Swan-Ganz - right heart catheterization To use the sharing features on this page, please enable JavaScript. Swan-Ganz catheterization is the passing of a thin ...
2014-01-01
Background Medical students often learn the skills necessary to perform a central venous catheterization in the operating room after simulator training. We examined the performance of central venous catheterization by medical students from the logbooks during their rotation in department of anesthesiology. Methods From the logbooks of medical students rotating in our department between January 2011 and June 2012, we obtained the kind and the number of central venous catheterization students had done, the results of the procedures whether they were success or failed, the reasons of the failures, complications, and the student self-reported confidence and satisfaction of their performance. Results There were 93 medical students performed 875 central venous catheterizations with landmark guidance on patients in the operating theater, and the mean number of catheterizations performed per student was 9.4 ± 2.0, with a success rate of 67.3%. Adjusted for age, sex, body mass index, surgical category, ASA score and insertion site, the odds of successful catherization improved with cumulative practice (odds ratio 1.10 per additional central venous catheterization performed; 95% confidence interval 1.05–1.15). The major challenge students encountered during the procedure was the difficulty of finding the central veins, which led to 185 catheterizations failed. The complication rate of central venous catheterization by the students was 7.8%, while the most common complication was puncture of artery. The satisfaction and confidence of students regarding their performance increased with each additional procedure and decreased significantly if failure or complications had occurred. Conclusion A student logbook is a useful tool for recording the actual procedural performance of students. From the logbooks, we could see the students’ performance, challenges, satisfaction and confidence of central venous catheterization were improved through cumulative clinical practice of the procedure. PMID:25123826
Maroney, Justin; Khan, Saba; Powell, Wayne; Klein, Lloyd W
2013-01-01
We seek to assess the per-operator volume of diagnostic catheterizations and percutaneous coronary interventions (PCI) among US cardiologists, and its implication for future manpower needs in the catheterization laboratory. The number of annual Medicare PCIs peaked in 2004 and has trended downward since, however the total number of catheterization laboratories nationwide has increased. It is unknown whether these trends have resulted in a dilution of per-operator volumes, and whether the current supply of interventional cardiologists is appropriate to meet future needs. We analyzed the Centers for Medicare and Medicaid Services 2008 Medicare 5% sample file, and extracted the total number of Medicare fee-for-service (Medicare FFS) diagnostic catheterizations and PCIs performed in 2008. We then determined per-physician procedure volumes using National Provider Identifier numbers. There were 1,198,610 Medicare FFS diagnostic catheterizations performed by 11,029 diagnostic cardiologists, and there were 378,372 Medicare FFS PCIs performed by 6,443 interventional cardiologists in 2008. The data reveal a marked difference in the 2008 distribution of diagnostic catheterizations and PCIs among operators. Just over 10% of diagnostic catheterizations were performed by operators performing 40 or fewer Medicare FFS diagnostic catheterizations, contrasted with almost 30% of PCIs performed by operators with 40 of fewer Medicare FFS PCIs. A significant majority of interventional cardiologists (61%) performed 40 or fewer Medicare FFS PCIs in 2008. There is a high percentage of low-volume operators performing PCI, raising questions regarding annual volume recommendations for procedural skill maintenance, and the future manpower requirements in the catheterization laboratory. Copyright © 2012 Wiley Periodicals, Inc.
Fallopian Tube Catheterization
Thurmond, Amy Suzanne
2013-01-01
Fallopian tube catheterization is used for treatment of infertility caused by proximal tubal occlusion, and has replaced surgical treatment for this condition. More recently, fallopian tube catheterization has been used for tubal sterilization. Interventional radiologists tested numerous methods for tubal occlusion using the rabbit as an animal model. As a result, a tubal device has recently been Food and Drug Administration approved for permanent sterilization using hysteroscopic guidance; it can also be placed fluoroscopically by fallopian tube catheterization as an “off-label” procedure. This is a 5-year continuation and update on a procedure that has been done by interventional radiologists for 25 years; history of the development of fallopian tube catheterization in women has been published in detail in this journal. Highlighted in this article will be description of the basic components needed for fallopian tube catheterization. PMID:24436565
Seckeler, Michael D; Hirsch, Russel; Beekman, Robert H; Goldstein, Bryan H
2014-01-01
To validate a method for determination of cardiac index (CI) using real-time measurement of oxygen consumption (VO2 ) in young children undergoing cardiac catheterization. Retrospective review comparing thermodilution cardiac index (TDCI) to CI calculated by the Fick equation using real-time measured VO2 (RT-VO2 ) and VO2 derived from 2 published predictive equations. Paired t-test and Bland-Altman analysis were used to compare TDCI to Fick CI. A survey to ascertain pediatric cardiac catheterization practices regarding VO2 determination was also conducted. Quaternary care children's hospital cardiac catheterization laboratory. Children <3 years old with structurally normal hearts undergoing cardiac catheterization under general anesthesia with at least one set of contemporaneous TDCI and RT-VO2 measurements. Thirty-six paired measurements of TDCI and RT-VO2 were made in 27 patients over a 2-year period. Indications for catheterization included congenital diaphragmatic hernia postrepair (n = 13), heart disease post-orthotopic heart transplant (n = 13), and suspected cardiomyopathy (n = 1). Mean age was 21.5 ± 8 months; median weight was 9.9 kg (IQR 8.57, 12.2). RT-VO2 was higher than VO2 predicted by the LaFarge equation (190 ± 31 vs. 173.8 ± 12.8 mL/min/m(2), P < .001), but there was no difference between TDCI and Fick CI calculated using VO2 from any method. Bland-Altman analysis showed excellent agreement between TDCI and Fick CI using RT-VO2 and VO2 predicted by the Lundell equation; Fick CI using VO2 predicted by the LaFarge equation showed fair agreement with TDCI. In children <3 years with a structurally normal heart, RT-VO2 generates highly accurate determinations of Fick CI as compared with TDCI. Additionally, in this population, VO2 derived from the LaFarge and Lundell equations generates accurate Fick CI compared with TDCI. Future studies are needed to identify factors associated with inaccurate VO2 generated from these predictive equations. © 2013 Wiley Periodicals, Inc.
Clinical Relevance of Coronary Fractional Flow Reserve: Art-of-state.
Adiputra, Yohanes; Chen, Shao-Liang
2015-05-20
The objective was to delineate the current knowledge of fractional flow reserve (FFR) in terms of definition, features, clinical applications, and pitfalls of measurement of FFR. We searched database for primary studies published in English. The database of National Library of Medicine (NLM), MEDLINE, and PubMed up to July 2014 was used to conduct a search using the keyword term "FFR". The articles about the definition, features, clinical application, and pitfalls of measurement of FFR were identified, retrieved, and reviewed. Coronary pressure-derived FFR rapidly assesses the hemodynamic significance of individual coronary artery lesions and can readily be performed in the catheterization laboratory. The use of FFR has been shown to effectively guide coronary revascularization procedures leading to improved patient outcomes. FFR is a valuable tool to determine the functional significance of coronary stenosis. It combines physiological and anatomical information, and can be followed immediately by percutaneous coronary intervention (PCI) if necessary. The technique of FFR measurement can be performed easily, rapidly, and safely in the catheterization laboratory. By systematic use of FFR in dubious stenosis and multi-vessel disease, PCI can be made an even more effective and better treatment than it is currently. The current clinical evidence for FFR should encourage cardiologists to use this tool in the catheterization laboratory.
Yang, Huan; Wang, Ning; Han, Shanfu; Male, Musa; Zhao, Chenming; Yao, Daqiang; Chen, Zhiqiang
2017-12-01
The transurethral resection of bladder tumor (TURBT) remains the most widely used method in the surgical treatment of the non-muscle invasive bladder tumor (NMIBT). Despite its popularity, the laser technique has been widely used in urology as an alternative, via the application of transurethral laser enucleation of bladder tumor. The aim of the present study was to compare the efficacy and feasibility between transurethral laser enucleation and transurethral resection of bladder tumor. A systematic search of the following databases was conducted: PubMed, Wed of Science, Cochrane Library, EMBASE, Google scholar, and Medline. The search included studies up to the 1st of January 2017. The outcomes of interest that were used in order to assess the two techniques included operation time, catheterization time, hospitalization time, obturator nerve reflex, bladder perforation, bladder irritation, 24-month-recurrence rate, and the postoperative adjuvant intravesical chemotherapy. A total of 13 trials with 2012 participants were included, of which 975 and 1037 underwent transurethral laser enucleation and transurethral resection of bladder tumor, respectively. No significant difference was noted in the operation time between the two groups, although significant differences were reported for the variables catheterization time, hospitalization time, obturator nerve reflex, bladder perforation, bladder irritation, and 24-month-recurrence rate. In the mitomycin and epirubicin subgroups, no significant differences were observed in the laser enucleation and TURBT methods with regard to the 24-month-recurrence rate. The laser enucleation was superior to TURBT with regard to the parameters obturator nerve reflex, bladder perforation, catheterization time, hospitalization time, and 24-month-recurrence rate. Moreover, laser enucleation can offer a more accurate result of the tumor's pathological stage and grade.
Use of the 2.8 French Progreat microcatheter in diagnostic cerebral angiography.
Griauzde, Julius; Gemmete, Joseph J; Shastri, Ravi; Pandey, Aditya S; Chaudhary, Neeraj
2017-01-01
Tortuous vascular anatomy poses a significant challenge to performing diagnostic cerebral angiography. To report a new cerebral angiography technique for overcoming tortuous aortic and supra-aortic anatomy using a 2.8 French (F) Progreat microcatheter (0.028 inch (internal diameter) (Terumo; Somerset, New Jersey, USA) to obtain a diagnostic cerebral angiogram. A retrospective analysis of consecutive cases undergoing diagnostic cerebral angiography at our institution between 1 January 2013 and 30 November 2015 in which a 2.8F Progreat microcatheter was used. Clinical and operative notes were reviewed and correlated with imaging. Radiologic imaging, including CT, MRI, and digital subtraction angiography, was reviewed. Neurologic, systemic, and local complications were recorded on the basis of clinical follow-up results after each angiographic examination. Events that occurred within 24 h of the angiography were considered to be complications of the procedure. Initial attempts at catheterization of the target vessel with various 4F and 5F catheters were unsuccessful owing to tortuosity, atherosclerotic disease, or occlusion of the catheter in the target vessel. Microcatheterization of the target vessel was successful in 59/62 (95%) target vessels. A diagnostic cerebral angiogram with a power injection was obtained in 59 (100%) of the successfully catheterized vessels. In one case, angiography proceeded to aneurysm coiling after over-the-wire exchange. In two cases, angiography proceeded to mechanical thrombectomy after over-the-wire exchange. No procedural complications were seen. The 2.8F Progreat microcatheter can be used to obtain a diagnostic cerebral angiogram in patients with anatomic challenges limiting catheterization by standard techniques. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Dasa, Osama; Shafiq, Qaiser; Ruzieh, Mohammed; Alhazmi, Luai; Al-Dabbas, Maen; Ammari, Zaid; Khouri, Samer; Moukarbel, George
2017-12-01
Right heart catheterization (RHC) is routinely performed to assess hemodynamics. Generally, anticoagulants are held prior to the procedure. At our center, anticoagulants are continued and ultrasound guidance is always used for internal jugular vein access. A micropuncture access kit is used to place a 5 or 6 Fr sheath using the modified Seldinger technique. Manual compression is applied for 10-15 min and the patient is observed for at least 2 hours after the procedure. In a retrospective analysis, we investigated the risk of bleeding complications associated with RHC via the internal jugular vein in patients with and without full anticoagulation. Our catheterization laboratory database was searched for adult patients who underwent RHC by a single operator between January 2012 and December 2015. A total of 571 patients were included in the analysis. Baseline characteristics, labs, relevant invasive hemodynamics, co-morbid conditions, and incidence of access-site hematoma are presented. Multivariable binary logistic regression was performed using IBM SPSS v. 23.0 software. Statistically significant associations with access-site hematoma were observed with body mass index (P=.02; 95% confidence interval [CI], 1.0-1.1), right atrial pressure (P=.03; 95% CI, 0.7-0.9), and dialysis dependence (P<.01; 95% CI, 0.1-0.6). There was no association of access-site hematoma with the use of anticoagulants (P>.99). The incidence of internal jugular vein access-site hematoma is small when using careful access techniques for RHC even with the continued use of novel oral anticoagulants and warfarin. Patient characteristics and co-morbid conditions are related to bleeding complications.
Dharma, Surya; Kedev, Sasko; Patel, Tejas; Sukmawan, Renan; Gilchrist, Ian C; Rao, Sunil V
2016-01-01
We analyzed the effect of nitroglycerin on radial artery occlusion (RAO) in women undergoing transradial catheterization. A total of 1706 patients undergoing transradial catheterization were randomized to receive either 500μg intra-arterial nitroglycerin or placebo at the end of the radial procedure. We explored the gender-based analysis between women (n=539) and men (n=1167). The primary outcome was the incidence of RAO as confirmed by absence of antegrade flow at one day after the transradial procedure evaluated by duplex ultrasound of the radial artery. The use of nitroglycerin, as compared with placebo, did not significantly reduce the risk of RAO in women patients [odds ratio, 0.69; 95% confidence interval (CI), 0.38 to 1.26; P=0.147]. The risk of RAO was higher in women age <60years as compared with women age ≥60years [5.6% vs. 3.5%; odds ratio, 2.16; 95% CI, 1.18 to 3.94; P=0.008]. In women age <60years (n=237), both counter puncture technique and a duration of hemostasis ≥4h were associated with a similar enhanced risk of developing RAO (odds ratio, 3.51; 95% CI, 1.59 to 7.72; P<0.001). The administration of nitroglycerin at the end of a transradial catheterization in women did not reduce the risk of RAO as determined by ultrasound one day after the radial procedure. Age <60years was associated with a higher risk of RAO compared with age ≥60years in women. Further strategies to reduce RAO in women are needed. Copyright © 2015 Elsevier Inc. All rights reserved.
Leng, Lewis Z; Kimball, David; Marcus, Joshua; Knopman, Jared; Laufer, Ilya; Bilsky, Mark; Gobin, Y Pierre
2016-01-01
Objective The existing literature regarding preoperative cervical spinal tumor embolization is sparse, with few discussions on the indications, risks, and best techniques. We present our experience with the preoperative endovascular management of hypervascular cervical spinal tumors. Methods We performed a retrospective review of all patients who underwent preoperative spinal angiography (regardless of whether tumor embolization was performed) at our institution (from 2002 to 2012) for primary and metastatic cervical spinal tumors. Tumor vascularity was graded from 0 (tumor blush equal to the normal adjacent vertebral body) to 3 (intense tumor blush with arteriovenous shunting). Tumors were considered “hypervascular” if they had a tumor vascular grade from 1 to 3. Embolic materials included particles, liquid embolics, and detachable coils. The main embolization technique was superselective catheterization of an arterial tumor feeder followed by injection of embolic material. This technique could be used alone or supplemented with occlusion of dangerous anastomoses of the vertebral artery as needed to prevent inadvertent embolization of the vertebrobasilar system. In cases when superselective catheterization of the tumoral feeder was not feasible, embolization was performed from a proximal catheter position after occlusion of branches supplying areas other than the tumor (“flow diversion”). Results A total of 47 patients with 49 cervical spinal tumors were included in this study. Of the 49 total tumors, 41 demonstrated increased vascularity (vascularity score > 0). The most common tumor pathology in our series was renal cell carcinoma (RCC) (N = 16; 32.7% of all tumors) followed by thyroid carcinoma (N = 7; 14.3% of all tumors). Tumor embolization was undertaken in 25 hypervascular tumors resulting in complete, near-complete, and partial embolization in 36.0% (N = 9), 44.0% (N = 11), and 20.0% (N = 5) of embolized tumors, respectively. We embolized 42 tumor feeders in 25 tumors. The most commonly embolized tumor feeders were branches of the vertebral artery (19.0%; N = 8), the deep cervical artery (19.0%; N = 8), and the ascending cervical artery (19.0%; N = 8). Sixteen hypervascular tumors were not embolized because of minimal hypervascularity (8/16), unacceptably high risk of spinal cord or vertebrobasilar ischemia (4/16), failed superselective catheterization of tumor feeder (3/16), and cancellation of surgery (1/16). Vertebral artery occlusion was performed in 20% of embolizations. There were no new post-procedure neurological deficits or any serious adverse events. Estimated blood loss data from this cohort show a significant decrease in operative blood loss for embolized tumors of moderate and significant hypervascularity. Conclusions Preoperative embolization of cervical spinal tumors can be performed safely and effectively in centers with significant experience and a standardized approach. PMID:27020696
Race Differences in Cardiac Catheterization: The Role of Social Contextual Variables
Kressin, Nancy R.
2010-01-01
BACKGROUND Race differences in the receipt of invasive cardiac procedures are well-documented but the etiology remains poorly understood. OBJECTIVE We examined how social contextual variables were related to race differences in the likelihood of receiving cardiac catheterization in a sample of veterans who were recommended to undergo the procedure by a physician. DESIGN Prospective observational cohort study. PARTICIPANTS A subsample from a study examining race disparities in cardiac catheterization of 48 Black/African American and 189 White veterans who were recommended by a physician to undergo cardiac catheterization. MEASURES We assessed social contextual variables (e.g., knowing somebody who had the procedure, being encouraged by family or friends), clinical variables (e.g., hypertension, maximal medical therapy), and if participants received cardiac catheterization at any point during the study. KEY RESULTS Blacks/African Americans were less likely to undergo cardiac catheterization compared to Whites even after controlling for age, education, and clinical variables (OR = 0.31; 95% CI, 0.13, 0.75). After controlling for demographic and clinical variables, three social contextual variables were significantly related to increased likelihood of receiving catheterization: knowing someone who had undergone the procedure (OR = 3.14; 95% CI, 1.70, 8.74), social support (OR = 2.05; 95% CI, 1.17, 2.78), and being encouraged by family to have procedure (OR = 1.45; 95% CI, 1.08, 1.90). After adding the social contextual variables, race was no longer significantly related to the likelihood of receiving catheterization, thus suggesting that social context plays an important role in the relationship between race and cardiac catheterization. CONCLUSIONS Our results suggest that social contextual factors are related to the likelihood of receiving recommended care. In addition, accounting for these relationships attenuated the observed race disparities between Whites and Blacks/African Americans who were recommended to undergo cardiac catheterization by their physicians. PMID:20383600
Lau, Hung; Lam, Becky
2004-08-01
There has been no consensus on the best catheterization strategy for the management of postoperative urinary retention. A prospective randomized trial was undertaken to establish the best practice guidelines for the management of postoperative urinary retention. The authors also evaluated the contemporary incidence of urinary retention following different categories of general surgery and examined risk factors associated with its occurrence. All patients who underwent elective inpatient surgery between January 2002 and June 2003 were recruited into the study. Patients who developed postoperative urinary retention were randomized to either having in-out catheterization or placement of an indwelling catheter for 24 h after surgery. A total of 1448 patients was recruited. The overall incidence of urinary retention was 4.1% (n = 60). Significant risk factors associated with postoperative urinary retention included old age, anorectal procedures and use of spinal anaesthesia. Comparison of re-catheterization and urinary tract infection rates between patients who were treated with in-out versus overnight catheterization found no significant differences. Postoperative urinary retention should be managed by in-out catheterization. Indwelling catheterization for 24 h appeared to bestow no additional benefits. The incidence of urinary retention increases with age, anorectal procedures and the use of spinal anaesthesia.
Schumm, K; Lam, T B L
2008-01-01
Urinary tract infection (UTI) is the most common hospital acquired infection. The major associated cause is indwelling urinary catheters. Currently there are many types of catheters available. A variety of specialized urethral catheters have been designed to reduce the risk of infection. These include antiseptic impregnated catheters and antibiotic impregnated catheters. Other issues that should be considered when choosing a catheter are ease of use, comfort and cost. The primary objective of this review was to determine the effect of type of indwelling urethral catheter on the risk of urinary tract infection in adults who undergo short-term urinary catheterization. We searched the Specialized Trials Register of the Cochrane Incontinence Group (searched September 11, 2007). We also examined the bibliographies of relevant articles and contacted catheter manufacturer representatives for trials. All randomized and quasi-randomized trials comparing types of indwelling urinary catheters for short-term catheterization in hospitalized adults. Short-term catheterization was defined as up to and including 14 days, or other temporary short-term use as defined by the trialists (for example <21 days with data time points at 7-day intervals). Data were extracted by one reviewer and independently verified by a second reviewer for both the original review and for the update. Disagreements were resolved by discussion. Data were processed as described in the Cochrane Handbook. Where data in trials were not fully reported, clarification was sought directly from the trialists (secondary sources were used to confirm results of one trial). Twenty-three trials met the inclusion criteria involving 5,236 hospitalized adults in 22 parallel group trials and 27,878 adults in one large cluster-randomized cross-over trial. The antiseptic catheters were either impregnated with silver oxide or silver alloy. Silver oxide catheters were not associated with a statistically significant reduction in bacteriuria in short-term catheterized hospitalized adults but the confidence intervals were wide (RR 0.89, 95% CI 0.68-1.15) and these catheters are no longer available. Silver alloy catheters were found to significantly reduce the incidence of asymptomatic bacteriuria (RR 0.54, 95% CI 0.43-0.67) in hospitalized adults catheterized for <1 week. At >1 week of catheterization the risk of asymptomatic bacteriuria was still reduced with the use of silver alloy catheters (RR 0.64, 95% CI 0.51-0.80). The randomized cross-over trial of silver alloy catheters versus standard catheters was excluded from the pooled results because data were not available prior to crossover. The results of this trial indicated benefit from the silver alloy catheters and included an economic analysis that indicated cost savings of between 3.3% and 35.5%. Antibiotic impregnated catheters were compared to standard catheters and found to lower the rate of asymptomatic bacteriuria in the antibiotic group at <1 week of catheterization for both minocycline and rifampicin combined (RR 0.36, 95% CI 0.18-0.73), and nitrofurazone (RR 0.52, 95% CI 0.34-0.78). However, at >1 week the results were not statistically significant. One of 56 men in the antibiotic impregnated group had a symptomatic UTI compared with 6 of 68 who had standard catheters (RR 0.20, 95% CI 0.03-1.63). Three trials compared two different types of standard catheters (defined as catheters that are not impregnated with antiseptics or antibiotics) to investigate infection. Individual trials were too small to show whether or not one type of standard catheter reduced the risk of catheter related urinary tract infection compared to another type of standard catheter. The results suggest that the use of silver alloy indwelling catheters for catheterizing hospitalized adults short-term reduces the risk of catheter acquired urinary tract infection. Further economic evaluation is required to confirm that the reduction of infection compensates for the increased cost of silver alloy catheters. Catheters impregnated with antibiotics are also beneficial in reducing bacteriuria in hospitalized adults catheterized for <1 week but the data were too few to draw conclusions about those catheterized for longer. There was not enough evidence to suggest whether or not any standard catheter was better than another in terms of reducing the risk of urinary tract infection in hospitalized adults catheterized short-term. Siliconized catheters may be less likely to cause urethral side effects in men; however, this result should be interpreted with some caution as the trials were small and the outcome definitions and specific catheters compared varied. (c) 2008 Wiley-Liss, Inc.
Cardiac Catheterization (For Kids)
... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body Works ... Educators Search English Español Cardiac Catheterization KidsHealth / For Kids / Cardiac Catheterization Print en español Cateterización cardíaca What ...
Hepatic laceration as a life-threatening complication of umbilical venous catheterization.
Gülcan, Hande; Hanta, Deniz; Törer, Birgin; Temiz, Adbülkerim; Demir, Senay
2011-01-01
Umbilical venous catheterization is an intravenous infusion route for maintenance fluids, medications, blood products, and parenteral nutrition in preterm neonates. However, this procedure may be associated with several complications, such as infection, thrombosis, vessel perforation, and cardiac and hepatic injuries. Hepatic laceration is a rare but life-threatening complication of umbilical venous catheterization that is a result of direct injury through the liver parenchyma. Here, we present a preterm newborn with hepatic laceration as a rare and serious complication of umbilical venous catheterization.
2016-12-01
repair, bowel anastomosis, central venous catheterization , and bladder catheterization . We performed a multivariate analysis of variance (MANOVA) to...DC, Gould MK. Preventing complications of central venous catheterization . N Engl J Med 2003;348:1123–33. 15. Maithel S, Sierra R, Korndorffer J, et...subclavian-vein catheterization . N Engl J Med. 1994;331(26):1735-1738. 2. Taylor RW, Palagiri AV. Central venous catheter- ization. Crit Care Med. 2007;35(5
WU, TIANLIANG; ZANG, HONGCHENG
2016-01-01
The ultrasound probe and advancement of the needle during real-time ultrasound-assisted guidance of catheterization of the right internal jugular vein (RIJV) tend to collapse the vein, which reduces the success rate of the procedure. We have developed a novel puncture point-traction method (PPTM) to facilitate RIJV cannulation. The present study examined whether this method facilitated the performance of RIJV catheterization in anesthetized patients. In this study, 120 patients were randomly assigned to a group in which PPTM was performed (PPTM group, n=60) or a group in which it was not performed (non-PPTM group, n=60). One patient was excluded because of internal carotid artery puncture and 119 patients remained for analysis. The cross-sectional area (CSA), anteroposterior diameter (AD) and transverse diameter (TD) of the RIJV at the cricoid cartilage level following the induction of anesthesia and during catheterization were measured, and the number with obvious loss of resistance (NOLR), the number with easy aspiration of blood into syringe (NEABS) during advancement of the needle, and the number of first-pass punctures (NFPP) during catheterization were determined. In the non-PPTM group, the CSA was smaller during catheterization compared with that following the induction of anesthesia (P<0.01). In the PPTM group compared with the non-PPTM group during catheterization, the CSA was larger (P<0.01) and the AD (P<0.01) and TD (P<0.05) were wider; NOLR (P<0.01), NEABS (P<0.01) and NFPP (P<0.01) increased significantly. The findings from this study confirmed that the PPTM facilitated catheterization of the RIJV and improved the success rate of RIJV catheterization in anesthetized patients in the supine position. PMID:27347054
Central venous catheter-related thrombosis in senile male patients: New risk factors and predictors.
Liu, Gao; Fu, Zhi-Qing; Zhu, Ping; Li, Shi-Jun
2015-06-01
Central venous catheterization (CVC)-related venous thrombosis is a common but serious clinical complication, thus prevention and treatment on this problem should be extensively investigated. In this research, we aimed to investigate the incidence rate of CVC-related venous thrombosis in senile patients and give a further discussion on the related risk factors and predictors. A total of 324 hospitalized senile male patients subjected to CVC were selected. Retrospective investigation and analysis were conducted on age, underlying diseases, clinical medications, catheterization position and side, catheter retention time, and incidence of CVC-related venous thrombosis complications. Basic laboratory test results during catheterization and thrombogenesis were also collected and analyzed. Among the 324 patients, 20 cases (6.17%) of CVC-related venous thrombosis were diagnoseds. The incidence rate of CVC-related venous thrombosis in subclavian vein catheterization was significantly lower than that in femoral vein catheterization (P<0.01) and that in internal jugular vein catheterization (P<0.05). No statistically significant difference was found between femoral vein catheterization and internal jugular vein catheterization (P<0.05). Previous venous thrombosis history (P<0.01), high lactate dehydrogenase level (P<0.01), low high-density lipoprotein (HDL) level (P<0.05), and low albumin level (P<0.05) were found as risk factors or predictors of CVC-related venous thrombosis in senile male patients. Subclavian vein catheterization was the most appropriate choice among senile patients to decrease the incidence of CVC-related venous thrombosis. Previous venous thrombosis history, high lactate dehydrogenase level, low HDL level, and low albumin level were important risk factors in predicting CVC-related venous thrombosis.
Urinary Catheterization in Infants: When It's Knot so Simple.
Sheridan, David C; Burns, Beech; Mickley, Megan
2018-02-01
Pediatric fever is one of the most common presenting complaints to emergency departments (ED). While often due to a viral illness, in young children without a source the most common bacterial infection is pyelonephritis. For this reason, when no focal source can be identified a urinary specimen is recommended. In young children who are unable to urinate on demand, a straight catheter is required to obtain a sterile specimen. This is generally a benign procedure and is performed frequently in EDs. We report a case of a young girl who underwent straight bladder catheterization and was subsequently found to have a retained catheter that had become knotted in the bladder. This case report highlights a rare complication of this common procedure and describes the technique required to remove the catheter. An understanding of these issues may avoid the need for transfer to a pediatric facility or for subspecialty consultation.
[Congenital abnormalities of the aorta in children and adolescents].
Eichhorn, J G; Ley, S
2007-11-01
Aortic abnormalities are common cardiovascular malformations accounting for 15-20% of all congenital heart disease. Ultrafast CT and MR imaging are noninvasive, accurate and robust techniques that can be used in the diagnosis of aortic malformations. While their sensitivity in detecting vascular abnormalities seems to be as good as that of conventional catheter angiocardiography, at over 90%, they are superior in the diagnosis of potentially life-threatening complications, such as tracheal, bronchial, or esophageal compression. It has been shown that more than 80% of small children with aortic abnormalities benefit directly from the use of noninvasive imaging: either cardiac catheterization is no longer necessary or radiation doses and periods of general anesthesia for interventional catheterization procedures can be much reduced. The most important congenital abnormalities of the aorta in children and adolescents are presented with reference to examples, and the value of CT and MR angiography is documented.
Tam, John Kit Chung; Atasha, Asmat; Tan, Ann Kheng
2013-01-01
OBJECTIVES Iatrogenic subclavian artery puncture following central venous catheterization is a rare but potentially fatal complication. There are very few reports in the literature on this condition. We propose the use of video-assisted thoracic surgery (VATS) in the management of these injuries. METHODS The technique of VATS to manage subclavian artery injury was described. We presented the first reported case of successful repair of subclavian artery injury using VATS. RESULTS Using a two-incisional approach for VATS, the haemothorax was rapidly evacuated and the subclavian artery injury was successfully repaired using pledgetted sutures under direct thoracoscopic visualization. The patient had an uneventful postoperative recovery. CONCLUSIONS VATS can be successfully applied to repair subclavian artery injury. The advantages include rapid intrathoracic access, excellent thoracoscopic visualization of the thoracic inlet, and avoidance of the morbidity associated with open thoracotomy. PMID:23518293
Chang, Hui-Kuan; Peng, Tai-Chu; Wang, Ji-Hung; Lai, Hui-Ling
2011-01-01
Cardiovascular diseases are the number 1 cause of death globally. Cardiac catheterization is a key step in the diagnosis and management of cardiovascular diseases. Decreasing the stress of cardiac catheterization is a key factor in improving patients' well-being. The aim of the study was to explore the effect of music on psychophysiological indices in patients awaiting cardiac catheterization examination. Using a 2-group repeated-measures design, 54 subjects aged 47 to 70 years and scheduled for cardiac catheterization examination were recruited. The subjects were randomly assigned to either the music group (27 subjects) or the usual-care group (27 subjects). Subjects in the music group listened to 30 minutes of music, whereas the usual-care group rested quietly, as in routine care. The heart rate (HR), HR variability, and skin temperature (ST) were measured at 7 time points and were recorded by the MP150 recording system (BIOPAC Systems, Inc, Goleta, California). Heart rate variability was analyzed by power spectral analysis: low frequency, high frequency, and ratio of low frequency to high frequency. The state of anxiety was measured at baseline and at time 7. At the end of the study, the subjects' music preference was evaluated using a visual analog scale. Listening to music resulted in a significantly reduced state of anxiety (P = .003). Both the music and quiet rest groups noted the beneficial effects of decreased HR and increased ST (all P < .001). The treatment effects of both interventions on HR variability were inconclusive. Moreover, we also found that the higher the scores of the music preference, the lower the subjects' perceived anxiety level (P = .05). Our findings provide the necessary scientific support for the use of sedative music and quiet rest as safe and effective interventions against anxiety, as manifested in the subjects' anxiety state, HR, and ST.
Does perception of catheterization limit its use in pediatric UTI?
Selekman, Rachel E; Sanford, Melissa T; Ko, Lauren N; Allen, I Elaine; Copp, Hillary L
2017-02-01
Urinary tract infections (UTIs) affect 3-8% of febrile children annually, but correctly diagnosing UTI in young children can present a challenge. Diagnosis requires a non-contaminated urine sample, which requires catheterization or suprapubic aspiration in infants and young children that have not completed toilet training. To improve adherence to these guidelines, it is critical to understand the barriers to urine testing and catheterization. The purpose of this study was to investigate parental perception of pediatric UTI evaluation to better understand factors that impede urine testing prior to treatment of suspected UTI. We conducted an electronic, cross-sectional survey via social media targeting parents of children with a history of UTI. Participants were queried regarding demographics, urine specimen collection method, factors influencing urine collection method, and perception of the experience. Multivariable logistic regression was used to assess factors associated with catheterization distress and urine testing. Of 2726 survey respondents, > 80% were female and White; 74% of the children with a history of UTI were female. Fifty-six percent of parents perceived extreme distress with catheterization. Among parents whose child was catheterized, extreme distress was less likely perceived if the parent was White (OR 0.6, 95% CI 0.4-0.9) or if the child was circumcised (OR 0.7, 95% CI 0.4-0.98). Among those whose child was not catheterized, extreme distress was more likely if parents had a college education (OR 3.2, 95% CI 2.2-4.5) and the child was more than 1 year old (OR 1.7, 95% CI 1.2-2.5). Catheterization was less likely to be withheld if parents had a college education (OR 0.1, 95% CI 0.1-0.2), and if the child was circumcised (OR 0.5, 95% CI 0.3-0.8) or had only one UTI (OR 0.6, 95% CI 0.4-0.8) (Table). Parental education level, child age, and circumcision status play an important role in the subjective distress associated with catheterization. This highlights the substantial impact of parental factors on adherence to guidelines for children suspected of UTI. For example, college-educated parents were more likely to be offered catheterization. However, these parents are also more likely to associate the catheterization experience with extreme distress, possibly limiting their likelihood of consent to this procedure. More studies are required to better understand the impact of these factors on catheterization. But, it is clear that parental input has a substantial impact on the evaluation of their child's suspected UTI. Copyright © 2016. Published by Elsevier Ltd.
Benatta, Mohammed Amine
2018-01-01
This study focused on endoscopic examination of a prominent papilla which showed two separate orifices revealing separate entrance of the main pancreatic duct and of the common bile duct (A). This was the most rare anatomoendoscopic variation, accounting for only 10% of retrograde cholangiopancreatographies using endoscopic approach (ERCP). However, it facilitated selective biliary catheterization (SBC) in our patient, as one might have expected. Papilla had a pseudo polypoid appearance and a biliary orifice (BO) at the right angle toward the duodenal wall; hence this was a more difficult approach than that via the pancreatic orifice (PO) which, on the other hand, required undesired pancreatic catheterization (B). As SBC was the approach we decided to adopt, the special techniques to consider in this particular case were: transpancreatic sphincterotomy (TPS) alone or TPS after implantation of a pancreatic stent (PS). We opted for the second technique (STP + PS) and we noticed that the implantation of a PS resulted in better BO visualization (C). We could perform SBC without recourse to TPS. In this specific case, as in other cases of difficult SBC in our practice, PS has proven effectiveness.
[Quality of care indicators for benign prostatic hyperplasia. A qualitative study].
Navarro-Pérez, Jorge; Peiró, Salvador; Brotons-Muntó, Francisco; López-Alcina, Emilio; Real-Romaguera, Arcadio
2014-05-01
To assess quality of care indicators for benign prostatic hyperplasia (BPH), and to evaluate their strengths and weaknesses for incorporation into health information systems. Structured expert meeting, using procedures adapted from the nominal group techniques and the Rand consensus method. Valencian School of Health Studies. Forty panellists (74% doctors, 70% from primary care settings) with experience in the management of BPH from 15 departments of the Valencia Health Agency. Three workshops were held simultaneously (examination and diagnosis, drug therapy, and appropriateness and results), and the 15 quality indicators selected by the coordination group were assessed. Eleven of the 15 indicators scored in the range of high relevance. The 5 best rated were: the use of alpha-blockers + 5-alpha reductase inhibitor from certain severity level, digital rectal examination in the initial assessment, follow-up with the International Prostate Symptoms Score (IPSS), the rate of urgent catheterization in Hospital Accident & Emergency Units, initial assessment with the IPSS and the use of alpha-blockers prior to catheter removal for acute retention of urine. Some of the assessed indicators can be useful for incorporation into health information systems. Copyright © 2013 Elsevier España, S.L. All rights reserved.
Recent advances in cardiac catheterization for congenital heart disease
Kang, Sok-Leng; Benson, Lee
2018-01-01
The field of pediatric and adult congenital cardiac catheterization has evolved rapidly in recent years. This review will focus on some of the newer endovascular technological and management strategies now being applied in the pediatric interventional laboratory. Emerging imaging techniques such as three-dimensional (3D) rotational angiography, multi-modal image fusion, 3D printing, and holographic imaging have the potential to enhance our understanding of complex congenital heart lesions for diagnostic or interventional purposes. While fluoroscopy and standard angiography remain procedural cornerstones, improved equipment design has allowed for effective radiation exposure reduction strategies. Innovations in device design and implantation techniques have enabled the application of percutaneous therapies in a wider range of patients, especially those with prohibitive surgical risk. For example, there is growing experience in transcatheter duct occlusion in symptomatic low-weight or premature infants and stent implantation into the right ventricular outflow tract or arterial duct in cyanotic neonates with duct-dependent pulmonary circulations. The application of percutaneous pulmonary valve implantation has been extended to a broader patient population with dysfunctional ‘native’ right ventricular outflow tracts and has spurred the development of novel techniques and devices to solve associated anatomic challenges. Finally, hybrid strategies, combining cardiosurgical and interventional approaches, have enhanced our capabilities to provide care for those with the most complex of lesions while optimizing efficacy and safety. PMID:29636905
Teng, Yi; Ou, Mengchan; Yu, Hai
2018-02-01
To compare the transesophageal echocardiography (TEE) probe as a surface probe with the vascular probe for guiding internal jugular vein (IJV) catheterization. Prospective, randomized, controlled pilot study. University hospital. One hundred cardiac surgery patients, including 50 adult and 50 pediatric patients. Patients in the TEE probe group received right IJV catheterization using the TEE probe, while the vascular probe group used the vascular probe for catheterization. The puncture time, first-attempt success rate, quality of the imaging with needle tip positioning, wire positioning, and catheter positioning were recorded. The incidence of complication or any adverse event also was observed. Adult patients: In the vascular probe group, the success rate for first attempt IJV catheterization was 24/25 (96%), while in the TEE probe group, the success rate for first attempt IJV catheterization was 25/25 (100%). There was no statistical difference in the puncture time, image quality, needle tip positioning, wire positioning, and catheter positioning between groups (p > 0.05). Pediatric patients: The success rate for first-attempt IJV catheterization was 100% in both groups, and there were no statistical differences in the puncture time, image quality, and positioning between the 2 groups (p > 0.05). No complications or adverse events were observed in either group. The TEE probe, used as a surface probe, can be used to guide IJV puncturing and catheterization in cardiac surgery patients with favorable feasibility and safety. Copyright © 2018 Elsevier Inc. All rights reserved.
Suprapubic Bladder Catheterization of Male Spinal-Cord–Injured Sprague–Dawley Rats
Robinson, Mary A; Herron, Alan J; Goodwin, Bradford S; Grill, Raymond J
2012-01-01
The rat spinal-cord–injury (SCI) model is widely used to study the pathologic mechanisms that contribute to sensory and motor dysfunction in humans. This model is thought to mimic many of the negative outcomes experienced by humans after spinal contusion injury. We theorized that manual bladder expression contributed to the kidney and bladder lesions reported in previous studies using the rat SCI model. In the present study, rats were surgically implanted with bladder catheters after spinal contusion injury to provide continuous drainage of urine. After 72 h, the rats were euthanized and their kidneys and bladders examined histologically. BUN, serum creatinine, and urine protein were compared at 0 and 72 h after surgery. Kidney and bladder lesions were similar in SCI rats with and without implanted bladder catheters. BUN at 72 h was higher than baseline values in both groups, whereas serum creatinine was higher at 72 h compared with baseline values only in the catheterized rats. These findings indicate that suprapubic bladder catheterization does not reduce hydronephrosis in SCI rats and that the standard of care for bladder evacuation should continue to be manual expression of urine. PMID:22330872
Zhang, Hui; Zheng, Rongqin; Qian, Xiaoxian; Zhang, Chengxi; Hao, Baoshun; Huang, Zeping; Wu, Tao
2014-03-01
Wave intensity analysis (WIA) of the carotid artery was conducted to determine the changes that occur in left ventricular systolic function after administration of doxorubicin in rabbits. Each randomly selected rabbit was subject to routine ultrasound, WIA of the carotid artery, cardiac catheterization and pathologic examination every week and was followed for 16 wk. The first positive peak (WI1) of the carotid artery revealed that left ventricular systolic dysfunction occurred earlier than conventional indexes of heart function. WI1 was highly, positively correlated with the maximum rate of rise in left ventricular pressure in cardiac catheterization (r = 0.94, p < 0.01) and moderately negatively correlated with the apoptosis index of myocardial cells, an indicator of myocardial damage (r = -0.69, p < 0.01). Ultrasound WIA of the carotid artery sensitively reflects early myocardial damage and cardiac function, and the result is highly consistent with cardiac catheterization findings and the apoptosis index of myocardial cells. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Highstead, R. Grant; Tipton, Kevin D.; Creson, Daniel L.; Wolfe, Robert R.; Ferrando, Arny A.
2005-01-01
Metabolic investigations often utilize arteriovenous sampling and muscle biopsy. These investigations represent some risk to the subject. We examined 369 studies performed in the General Clinical Research Center between January 1994 and May 2003 for events related to femoral catheterization and muscle biopsies. Incidents were further examined by age (younger: 18-59 yr, n=133; and older: 60-76 yr, n=28). There were no clinically defined major complications associated with either procedure. The incidence of femoral catheter repositioning or reinsertion was higher in the older group (25.5 vs. 9.7%). There was no difference in the incidence of premature removal of catheters, ecchymosis or hematoma, or the persistence of pain after discharge. The occurrence of all incidents did not increase with multiple catheterizations. Muscle biopsy was associated with infrequent ecchymosis or hematoma in both groups (1.1 and 3.6% in younger and older groups, respectively). Both procedures entail a small likelihood of a vagallike response (3.3% overall), resulting in nausea, dizziness, and rarely a loss of consciousness. These results indicate that, in skilled hands and a defined clinical setting, the incidents associated with femoral catheterization and muscle biopsy in healthy volunteers are reasonable and largely controllable.
Clinical Relevance of Coronary Fractional Flow Reserve: Art-of-state
Adiputra, Yohanes; Chen, Shao-Liang
2015-01-01
Objective: The objective was to delineate the current knowledge of fractional flow reserve (FFR) in terms of definition, features, clinical applications, and pitfalls of measurement of FFR. Data Sources: We searched database for primary studies published in English. The database of National Library of Medicine (NLM), MEDLINE, and PubMed up to July 2014 was used to conduct a search using the keyword term “FFR”. Study Selection: The articles about the definition, features, clinical application, and pitfalls of measurement of FFR were identified, retrieved, and reviewed. Results: Coronary pressure-derived FFR rapidly assesses the hemodynamic significance of individual coronary artery lesions and can readily be performed in the catheterization laboratory. The use of FFR has been shown to effectively guide coronary revascularization procedures leading to improved patient outcomes. Conclusions: FFR is a valuable tool to determine the functional significance of coronary stenosis. It combines physiological and anatomical information, and can be followed immediately by percutaneous coronary intervention (PCI) if necessary. The technique of FFR measurement can be performed easily, rapidly, and safely in the catheterization laboratory. By systematic use of FFR in dubious stenosis and multi-vessel disease, PCI can be made an even more effective and better treatment than it is currently. The current clinical evidence for FFR should encourage cardiologists to use this tool in the catheterization laboratory. PMID:25963364
Wathen, Asheley B; Myers, Daniel D; Zajkowski, Paul; Flory, Graham; Hankenson, F Claire
2009-01-01
A chronically catheterized 14-y-old male rhesus macaque (Macaca mulatta) was reported for recurrent scrotal swelling. The scrotum was enlarged and warm to touch, and associated skin was noted to be lichenified on physical examination. The penis could not be extruded due to preputial swelling. Results from the following diagnostic tests were all unremarkable or within normal limits: scrotal aspirate, hematology, serum biochemistries, urinalysis, and radiography of the thorax, scrotum, and abdomen. Ultrasonography of lower extremities identified thrombi in bilateral iliac veins and left femoral vein. Collateral circulation surrounding the left femoral vein permitted some compensatory venous return. The left femoral vein of this animal had been catheterized approximately 2 mo before initial presentation. A coagulation panel revealed a positive D-dimer test, indicative of elevated levels of fibrin degradation products due to active thrombus breakdown. Enoxaparin sodium, a low-molecular-weight heparin for human use, was administered at 20 mg subcutaneously once daily for 10 d to treat occlusive venous thrombi. After enoxaparin treatment, the edema was greatly decreased. To achieve complete resolution, a second course of enoxaparin was administered 2 months after the first. Ultrasonography of the pelvic vasculature 6 mo after completion of therapy showed marked thrombus resolution, allowing for bilateral patency in the iliac and femoral veins. Follow-up evaluation revealed that D-dimer values were negative as well. This case demonstrates the novel application of the human medication enoxaparin to treat clinical signs of deep vein thrombosis in a chronically catheterized rhesus macaque. PMID:19807974
NASA Astrophysics Data System (ADS)
Dave, Jaydev K.
Ultrasound contrast agents (UCAs) are encapsulated microbubbles that provide a source for acoustic impedance mismatch with the blood, due to difference in compressibility between the gas contained within these microbubbles and the blood. When insonified by an ultrasound beam, these UCAs act as nonlinear scatterers and enhance the echoes of the incident pulse, resulting in scattering of the incident ultrasound beam and emission of fundamental (f0), subharmonic (f0/2), harmonic (n*f0; n ∈ N) and ultraharmonic (((2n-1)/2)*f0; n ∈ N & n > 1) components in the echo response. A promising approach to monitor in vivo pressures revolves around the fact that the ultrasound transmit and receive parameters can be selected to induce an ambient pressure amplitude dependent subharmonic signal. This subharmonic signal may be used to estimate ambient pressure amplitude; such technique of estimating ambient pressure amplitude is referred to as subharmonic aided pressure estimation or SHAPE. This project develops and evaluates the feasibility of SHAPE to noninvasively monitor cardiac and hepatic pressures (using commercially available ultrasound scanners and UCAs) because invasive catheter based pressure measurements are used currently for these applications. Invasive catheter based pressure measurements pose risk of introducing infection while the catheter is guided towards the region of interest in the body through a percutaneous incision, pose risk of death due to structural or mechanical failure of the catheter (which has also triggered product recalls by the USA Food and Drug Administration) and may potentially modulate the pressures that are being measured. Also, catheterization procedures require fluoroscopic guidance to advance the catheter to the site of pressure measurements and such catheterization procedures are not performed in all clinical centers. Thus, a noninvasive technique to obtain ambient pressure values without the catheterization process is clinically helpful. While an intravenous injection is required to inject the UCAs into the body, this procedure is considered noninvasive as per the definition provided by the Center for Medicare and Medicaid Services; invasive procedures include surgical procedures as well as catheterization procedures while minor procedures such as drawing blood (which requires a similar approach as injecting UCAs) are considered noninvasive. In vitro results showed that the standard error between catheter pressures and SHAPE results is below 10 mmHg with a correlation coefficient value of above 0.9—this experimental error of 10 mmHg is less than the errors associated with other techniques utilizing UCAs for ambient pressure estimation. In vivo results proved the feasibility of SHAPE to noninvasively estimate clinically relevant left and right ventricular (LV and RV) pressures. The maximum error in estimating the LV and RV systolic and diastolic pressures was 3.5 mmHg. Thus, the SHAPE technique may be useful for systolic and diastolic pressure estimation given that the standard recommendations require the errors for these pressure measurements to be within 5 mmHg. The ability of SHAPE to identify induced portal hypertension (PH) was also proved. The changes in the SHAPE data correlated significantly (p < 0.05) with the changes in the portal vein (PV) pressures and the absolute amplitudes of the subharmonic signal also correlated with absolute PV pressures. The SHAPE technique provides the ability to noninvasively obtain in vivo pressures. This technique is applicable not only for critically ill patients, but also for screening symptomatic patients and potentially for other clinical pressure monitoring applications, as well.
Du, Qing; Salem, Yasser; Liu, Hao Howe; Zhou, Xuan; Chen, Sun; Chen, Nan; Yang, Xiaoyan; Liang, Juping; Sun, Kun
2017-01-23
Cardiac catheterization has opened an innovative treatment field for cardiac disease; this treatment is becoming the most popular approach for pediatric congenital heart disease (CHD) and has led to a significant growth in the number of children with cardiac catheterization. Unfortunately, based on evidence, it has been demonstrated that the majority of children with CHD are at an increased risk of "non-cardiac" problems. Effective exercise therapy could improve their functional status significantly. As studies identifying the efficacy of exercise therapy are rare in this field, the aims of this study are to (1) identify the efficacy of a home-based exercise program to improve the motor function of children with CHD with cardiac catheterization, (2) reduce parental anxiety and parenting burden, and (3) improve the quality of life for parents whose children are diagnosed with CHD with cardiac catheterization through the program. A total of 300 children who will perform a cardiac catheterization will be randomly assigned to two groups: a home-based intervention group and a control group. The home-based intervention group will carry out a home-based exercise program, and the control group will receive only home-based exercise education. Assessments will be undertaken before catheterization and at 1, 3, and 6 months after catheterization. Motor ability quotients will be assessed as the primary outcomes. The modified Ross score, cardiac function, speed of sound at the tibia, functional independence of the children, anxiety, quality of life, and caregiver burden of their parents or the main caregivers will be the secondary outcome measurements. The proposed prospective randomized controlled trial will evaluate the efficiency of a home-based exercise program for children with CHD with cardiac catheterization. We anticipate that the home-based exercise program may represent a valuable and efficient intervention for children with CHD and their families. http://www.chictr.org.cn/ on: ChiCTR-IOR-16007762 . Registered on 13 January 2016.
Hsiao, Po-Jen; Tsai, Ming-Hsien; Leu, Jyh-Gang; Fang, Yu-Wei
2015-04-01
Iliopsoas abscess is a rare complication in hemodialysis patients that is mainly due to adjacent catheterization, local acupuncture, discitis, and bacteremia. Herein, we report a 47-year-old woman undergoing regular hemodialysis via a catheter in the internal jugular vein who presented with low back pain and dyspnea. A heart murmur suggested the presence of catheter-related endocarditis, and this was confirmed by an echocardiogram and a blood culture of methicillin-resistant Staphylococcus aureus. A computed tomography indicated a pulmonary embolism and an incidental finding of iliopsoas abscess. Following surgical intervention and intravenous daptomycin, the patient experienced full recovery and a return to usual activities. This case indicates that an iliopsoas abscess can be related to a jugular vein catheter, which is apparently facilitated by infective endocarditis. The possibility of iliopsoas abscess should be considered when a hemodialysis patient presents with severe low back pain, even when there is no history of adjacent mechanical intervention. © 2014 International Society for Hemodialysis.
U. S. Army Medical Research and Development Technical Report
1978-09-30
skin preparation prior to cathe- ter insertion, thi- type of catheter care following insertion, and the duration of central venous catheterization . An...NO. 3 A study is now underway to determine the optimal techniques for central venous catheter dressing care. A specially designed dress- ing tray that...chronically maintained male rhesus monkeys with indwelling central venous catheters. Two specific problems were en- countered. (1) Available data
Opioid Abuse After Traumatic Brain Injury: Evaluation Using Rodet Models
2014-07-01
the laboratory and handling, catheterization surgery and recovery, brain injury and evaluation of acquisition, reinforcing efficacy or reinstatement...o Acquisition behavior: 29 subjects were catheterized and underwent injury/sham injury with 20 subjects completing evaluation of acquisition... catheterized and underwent injury/sham injury with 8 subjects completing evaluation of relapse-like behavior. (Goals: 8 enter, 6 complete
Kim, Eugene; Kim, Hyun Joo; Hong, Deok Man; Park, Hee-Pyoung; Bahk, Jae-Hyon
2016-09-01
It remains unclear whether we have to interrupt mechanical ventilation during infraclavicular subclavian venous catheterization. In practice, the clinicians' choice about lung deflation depends on their own discretion. The purpose of this study was to assess the influence of mechanical ventilation on the incidence of pneumothorax during infraclavicular subclavian venous catheterization. A total of 332 patients, who needed subclavian venous catheterization, were randomly assigned to 1 of the 2 groups: catheterizations were performed with the patients' lungs under mechanical ventilation (ventilation group, n = 165) or without mechanical ventilation (deflation group, n = 167). The incidences of pneumothorax and other complications such as arterial puncture, hemothorax, or catheter misplacements and the success rate of catheterization were compared. The incidences of pneumothorax were 0% (0/165) in the ventilation group and 0.6% (1/167) in the deflation group. The incidence of pneumothorax in the deflation group was 0.6% higher than that in the ventilation group and the 2-sided 90% confidence interval for the difference was (-1.29% to 3.44%). Because the lower bound for the 2-sided 90% confidence interval, -1.29%, was higher than the predefined noninferiority margin of -3%, the inferiority of the ventilation group over the deflation group was rejected at the .05 level of significance. Other complication rates and success rates of catheterization were comparable between 2 groups. The oxygen saturation dropped below 95% in 9 patients in the deflation group, while none in the ventilation group (P = .007). The success and complication rates were similar regardless of mechanical ventilation. During infraclavicular subclavian venous catheterization, interruption of mechanical ventilation does not seem to be necessary for the prevention of pneumothorax.
Fabreau, Gabriel E; Leung, Alexander A; Southern, Danielle A; Knudtson, Merrill L; McWilliams, J Michael; Ayanian, John Z; Ghali, William A
2014-07-01
Sex and neighborhood socioeconomic status (nSES) may independently affect the care and outcomes of acute coronary syndrome, partly through barriers in timely access to cardiac catheterization. We sought to determine whether sex modifies the association between nSES and the receipt of cardiac catheterization and mortality after an acute coronary syndrome in a universal healthcare system. We studied 14 012 patients with acute coronary syndrome admitted to cardiology services between April 18, 2004, and December 31, 2011, in Southern Alberta, Canada. We used multivariable logistic regression to compare the odds of cardiac catheterization within 2 and 30 days of admission and the odds of 30-day and 1-year mortality for men and women by quintile of neighborhood median household income. Significant relationships between nSES and the receipt of cardiac catheterization and mortality after acute coronary syndrome were detected for women but not men. When examined by nSES, each incremental decrease in neighborhood income quintile for women was associated with a 6% lower odds of receiving cardiac catheterization within 30 days (P=0.01) and a 14% higher odds of 30-day mortality (P=0.03). For men, each decrease in neighborhood income quintile was associated with a 2% lower odds of receiving catheterization within 30 days (P=0.10) and a 5% higher odds of 30-day mortality (P=0.36). Associations between nSES and receipt of cardiac catheterization and 30-day mortality were noted for women but not men in a universal healthcare system. Care protocols designed to improve equity of access to care and outcomes are required, especially for low-income women. © 2014 American Heart Association, Inc.
Monti's procedure as an alternative technique in complex urethral distraction defect.
Hosseini, Jalil; Kaviani, Ali; Mazloomfard, Mohammad M; Golshan, Ali R
2010-01-01
Pelvic fracture urethral distraction defect is usually managed by the end to end anastomotic urethroplasty. Surgical repair of those patients with post-traumatic complex posterior urethral defects, who have undergone failed previous surgical treatments, remains one of the most challenging problems in urology. Appendix urinary diversion could be used in such cases. However, the appendix tissue is not always usable. We report our experience on management of patients with long urethral defect with history of one or more failed urethroplasties by Monti channel urinary diversion. From 2001 to 2007, we evaluated data from 8 male patients aged 28 to 76 years (mean age 42.5) in whom the Monti technique was performed. All cases had history of posterior urethral defect with one or more failed procedures for urethral reconstruction including urethroplasty. A 2 to 2.5 cm segment of ileum, which had a suitable blood supply, was cut. After the re-anastomosis of the ileum, we closed the opened ileum transversely surrounding a 14-16 Fr urethral catheter using running Vicryl sutures. The newly built tube was used as an appendix during diversion. All patients performed catheterization through the conduit without difficulty and stomal stenosis. Mild stomal incontinence occurred in one patient in the supine position who became continent after adjustment of the catheterization intervals. There was no dehiscence, necrosis or perforation of the tube. Based on our data, Monti's procedure seems to be a valuable technique in patients with very long complicated urethral defect who cannot be managed with routine urethroplastic techniques.
Rare malposition following left jugular vein catheterization: Case reports and a literature review.
Wang, Lin; Liu, Zhangsuo; Wang, Changan; Liu, Dongwei; Yuan, Yiqiang
2015-01-01
The number of patients requiring chronic hemodialysis via a tunneled cuffed catheter is increasing. The right internal jugular vein (IJV) is generally the preferred site of percutaneous insertion. In certain situations, for example, in patients with a history of multiple access failures, catheterization of the left IJV is an important option. In this report, we present two rare cases of catheter malposition after left IJV catheterization; catheter adjustments, with the help of chest radiographs, resulted in a positive outcome in both cases. These cases exemplify the difficulties associated with left IJV catheterization, of which there are few reports in the published literature.
Nykanen, David G; Forbes, Thomas J; Du, Wei; Divekar, Abhay A; Reeves, Jaxk H; Hagler, Donald J; Fagan, Thomas E; Pedra, Carlos A C; Fleming, Gregory A; Khan, Danyal M; Javois, Alexander J; Gruenstein, Daniel H; Qureshi, Shakeel A; Moore, Phillip M; Wax, David H
2016-02-01
We sought to develop a scoring system that predicts the risk of serious adverse events (SAE's) for individual pediatric patients undergoing cardiac catheterization procedures. Systematic assessment of risk of SAE in pediatric catheterization can be challenging in view of a wide variation in procedure and patient complexity as well as rapidly evolving technology. A 10 component scoring system was originally developed based on expert consensus and review of the existing literature. Data from an international multi-institutional catheterization registry (CCISC) between 2008 and 2013 were used to validate this scoring system. In addition we used multivariate methods to further refine the original risk score to improve its predictive power of SAE's. Univariate analysis confirmed the strong correlation of each of the 10 components of the original risk score with SAE attributed to a pediatric cardiac catheterization (P < 0.001 for all variables). Multivariate analysis resulted in a modified risk score (CRISP) that corresponds to an increase in value of area under a receiver operating characteristic curve (AUC) from 0.715 to 0.741. The CRISP score predicts risk of occurrence of an SAE for individual patients undergoing pediatric cardiac catheterization procedures. © 2015 Wiley Periodicals, Inc.
Daher, Paul; Khoury, Antoine; Riachy, Edward; Atallah, Bachir
2015-06-01
While there is little scientific evidence over the optimal duration for transurethral bladder catheterization after hypospadias repair, most surgeons leave the catheter for 7-10 days. We herein describe our experience with bladder catheterization for three weeks after hypospadias repair, an approach not previously described in the literature. We reviewed the charts of 189 patients who underwent hypospadias repair by a single pediatric urologist. The study population was divided as follows: group 1 consisted of children operated between March 2007 and September 2010 and whose catheters were left for one week (n=95); group 2 consisted of those operated between September 2010 and July 2013 and whose catheters were left for three weeks (n=94). The primary objective of the study was to compare complication rates between the two groups. Secondary outcomes were evaluation of the effect of age, surgical technique, curvature, and hypospadias degree as potential factors for postoperative complications. Median age at hypospadias repair was 18 months (range, 3-100 months) in group 1, and 16 months (range, 2-96 months) in group 2, P=.209. The complication rate was 22.1% (n=21) for group 1 and 7.4% (n=7) for group 2, P=.005. Complications observed in group 1 and 2 were meatal stenosis (n=4 and 2, respectively) and urethro-cutaneous fistulas (n=17 and 5, respectively). Coronal fistulas manifested more frequently in patients in group 1 compared to those in group 2 (13.7% vs. 3.2%, P=.01). Complications were observed in 20 patients out of 139 (11.5%) after Duplay, and in 8 patients out of 15 (53.3%) after Duckett (P<.001). In Duplay cases, complications were significantly associated with one-week bladder catheterization (OR: 5.00; 95% CI: 1.53-16.32; P=.008) and higher age group at operation (OR: 1.88; 95% CI 1.07-3.28; P=.026). In Duckett cases, number of surgeries, age, severity, curvature and catheter duration were not found to be associated with complications. In cases of Duplay, a three-week instead of one-week catheterization and age below 6 months at hypospadias repair are associated with a better outcome and fewer complications. Copyright © 2015 Elsevier Inc. All rights reserved.
KAYACI, Selim; KANAT, Ayhan; KOKSAL, Vaner; OZDEMIR, Bulent
2014-01-01
The postoperative results of chronic subdural hematoma (CSDH) procedures using catheterization and tearing of inner membrane (CTIM) technique have not previously been discussed in the literature. This article compares the effects of CTIM technique on brain re-expansion and re-accumulation with cases operated on with a burr-hole craniotomy and outer membrane incision (BCOMI) technique. The study involved operations on 144 patients (Group 1) using the CTIM technique and 108 patients (Group 2) using the BCOMI technique. In the operations using the CTIM technique in Group 1, the mean effusion measured in the subdural space (SDS) was 10.0 ± 0.2 mm, and for Group 2, 14.3 ± 0.6 mm in the postoperative period on the first and third days and this difference was found to be significant (p < 0.05). The means were 6.6 ± 0.2 mm for Group 1 and 10.3 ± 0.5 mm for Group 2 on the seventh day (p < 0.05). Recurrence rate was 8.3% in Group 2 and 0 in Group 1. This difference was statistically significant (p = 0001). The length of hospital stay was 7.0 ± 0.1 days for the Group 1 and 8.8 ± 0.2 days for Group 2 and this difference was significant (p < 0.05). These results indicate that the CTIM technique is preferable because it results in earlier re-expansion, lower recurrence, less subdural effusion and pneumocephalus, and shorter hospital stays. PMID:24477064
Kayaci, Selim; Kanat, Ayhan; Koksal, Vaner; Ozdemir, Bulent
2014-01-01
The postoperative results of chronic subdural hematoma (CSDH) procedures using catheterization and tearing of inner membrane (CTIM) technique have not previously been discussed in the literature. This article compares the effects of CTIM technique on brain re-expansion and re-accumulation with cases operated on with a burr-hole craniotomy and outer membrane incision (BCOMI) technique. The study involved operations on 144 patients (Group 1) using the CTIM technique and 108 patients (Group 2) using the BCOMI technique. In the operations using the CTIM technique in Group 1, the mean effusion measured in the subdural space (SDS) was 10.0 ± 0.2 mm, and for Group 2, 14.3 ± 0.6 mm in the postoperative period on the first and third days and this difference was found to be significant (p < 0.05). The means were 6.6 ± 0.2 mm for Group 1 and 10.3 ± 0.5 mm for Group 2 on the seventh day (p < 0.05). Recurrence rate was 8.3% in Group 2 and 0 in Group 1. This difference was statistically significant (p = 0001). The length of hospital stay was 7.0 ± 0.1 days for the Group 1 and 8.8 ± 0.2 days for Group 2 and this difference was significant (p < 0.05). These results indicate that the CTIM technique is preferable because it results in earlier re-expansion, lower recurrence, less subdural effusion and pneumocephalus, and shorter hospital stays.
Viral Oncolytic Therapeutics for Neoplastic Meningitis
2013-07-01
infusion method, we worked with our animal vendor, Charles River Laboratories (CRL), to adopt their intrathecal catheterization service for our...traslocation of the injected material in CSF, we attempted to correlate the parameters of lumbar bolus in intrathecally catheterized rats with those in non...explained by either partial blockage of the spinal CSF compartment in catheterized animals or by variable posterior hydrodynamic compliance (or both) and
2008 International Meeting on Simulation in Healthcare
2008-05-01
procedural simulator to teach central venous catheterization (CVC). METHODS: Fourth year medical students (n 12) at the Medical College of Georgia...RESEARCH ABSTRACT 51 Use of A Variety of Simulation Modalities in a Graduate Medical Education Safety Initiative on Central Venous Catheterization Walter...events associated with central venous catheterization (CVC) procedures is well-established.1–2 The overall goal of this multidis- ciplinary project
Opioid Abuse after Traumatic Brain Injury: Evaluation Using Rodent Models
2013-07-01
acclimation to the laboratory and handling, catheterization surgery and recovery, brain injury and evaluation of acquisition, reinforcing efficacy or...subjects entered into protocol =112 (10+10+20+22+ 24+26) Total number catheterized =62 Total number undergoing sham injury =33...did not enter into the experimental protocol until after VCU IACUC and ACURO approval in July 2013. Twenty-two subjects have been catheterized and
Wang, Kai; Li, Yao; Teng, Jing-Fei; Zhou, Hai-Yong; Xu, Dan-Feng; Fan, Yi
2015-01-01
To evaluate the efficacy and safety of plasmakinetic resection of the prostate (PKRP) versus transurethral resection of the prostate (TURP) for the treatment of patients with benign prostate hyperplasia (BPH), a meta-analysis of randomized controlled trials was carried out. We searched PubMed, Embase, Web of Science and the Cochrane Library. The pooled estimates of maximum flow rate, International Prostate Symptom Score, operation time, catheterization time, irrigated volume, hospital stay, transurethral resection syndrome, transfusion, clot retention, urinary retention and urinary stricture were assessed. There was no notable difference in International Prostate Symptom Score between TURP and PKRP groups during the 1-month, 3 months, 6 months and 12 months follow-up period, while the pooled Q max at 1-month favored PKRP group. PKRP group was related to a lower risk rate of transurethral resection syndrome, transfusion and clot retention, and the catheterization time and operation time were also shorter than that of TURP. The irrigated volume, length of hospital stay, urinary retention and urinary stricture rate were similar between groups. In conclusion, our study suggests that the PKRP is a reliable minimal invasive technique and may anticipatorily prove to be an alternative electrosurgical procedure for the treatment of BPH.
Bhattacharjee, Sulagna; Maitra, Souvik; Baidya, Dalim K
2018-06-01
Possible advantages and risks associated with ultrasound guided radial artery cannulation in-comparison to digital palpation guided method in adult patients are not fully known. We have compared ultrasound guided radial artery cannulation with digital palpation technique in this meta-analysis. Meta-analysis of randomized controlled trials. Trials conducted in operating room, emergency department, cardiac catheterization laboratory. PubMed and Cochrane Central Register of Controlled Trials (CENTRAL) were searched (from 1946 to 20th November 2017) to identify prospective randomized controlled trials in adult patients. Two-dimensional ultrasound guided radial artery catheterization versus digital palpation guided radial artery cannulation. Overall cannulation success rate, first attempt success rate, time to cannulation and mean number of attempts to successful cannulation. Odds ratio (OR) and standardized mean difference (SMD) or mean difference (MD) with 95% confidence interval (CI) were calculated for categorical and continuous variables respectively. Data of 1895 patients from 10 studies have been included in this meta- analysis. Overall cannulation success rate was similar between ultrasound guided technique and digital palpation [OR (95% CI) 2.01 (1.00, 4.06); p = 0.05]. Ultrasound guided radial artery cannulation is associated with higher first attempt success rate of radial artery cannulation in comparison to digital palpation [OR (95% CI) 2.76 (186, 4.10); p < 0.001]. No difference was seen in time to cannulate [SMD (95% CI) -0.31 (-0.65, 0.04); p = 0.30] and mean number of attempt [MD (95% CI) -0.65 (-1.32, 0.02); p = 0.06] between USG guided technique with palpation technique. Radial artery cannulation by ultrasound guidance may increase the first attempt success rate but not the overall cannulation success when compared to digital palpation technique. However, results of this meta-analysis should be interpreted with caution due presence of heterogeneity. Copyright © 2018 Elsevier Inc. All rights reserved.
Goldfarb, Robert A; Pisansky, Andrew; Fleck, Joseph; Hoversten, Patrick; Cotter, Katherine J; Katorski, Jenna; Liberman, Daniel; Elliott, Sean P
2016-04-01
Cerebral palsy is characterized by motor impairment following injury to the developing brain. Neurogenic lower urinary tract dysfunction is estimated to affect at least a third of children with cerebral palsy. However there are limited data as patients transition to adulthood. We sought to describe the symptoms, sequelae and management of neurogenic lower urinary tract dysfunction in adults with cerebral palsy. We retrospectively reviewed the charts of adult patients with cerebral palsy between 2011 and 2014. Patients with prior bladder reconstruction or catheterization based bladder drainage were excluded from study. Cerebral palsy severity was determined using GMFCS (Gross Motor Function Classification System). A conservative evaluation and treatment paradigm was used. Noninvasive treatments were encouraged. Specifically clean intermittent catheterization, which is often not feasible, is avoided unless urinary retention, hydronephrosis or refractory lower urinary tract symptoms develop. There were 121 patients included in final analysis. Median age was 25 and 61 patients (50%) had GMFCS level V. Noninvasive management failed in 28 of 121 patients (23%) as defined by hydronephrosis in 9, persistent urinary retention in 10 and refractory lower urinary tract symptoms/incontinence in 9. Urethral clean intermittent catheterization was poorly tolerated. Of all patients 25% showed evidence of urolithiasis during the study period. Surgical intervention was rare and associated with significant morbidity. Adults with cerebral palsy may present with variable signs and symptoms of neurogenic lower urinary tract dysfunction. Conservative treatment was successful in more than 75% of patients. Clean intermittent catheterization was poorly tolerated in patients in whom conservative treatment failed. Surgical intervention was rarely indicated and it should be reserved for select individuals. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Holmium laser enucleation versus laparoscopic simple prostatectomy for large adenomas.
Juaneda, R; Thanigasalam, R; Rizk, J; Perrot, E; Theveniaud, P E; Baumert, H
2016-01-01
The aim of this study is to compare Holmium laser enucleation of the prostate with another minimally invasive technique, the laparoscopic simple prostatectomy. We compared outcomes of a series of 40 patients who underwent laparoscopic simple prostatectomy (n=20) with laser enucleation of the prostate (n=20) for large adenomas (>100 grams) at our institution. Study variables included operative time and catheterization time, hospital stay, pre- and post-operative International Prostate Symptom Score and maximum urinary flow rate, complications and economic evaluation. Statistical analyses were performed using the Student t test and Fisher test. There were no significant differences in patient age, preoperative prostatic size, operating time or specimen weight between the 2 groups. Duration of catheterization (P=.0008) and hospital stay (P<.0001) were significantly less in the laser group. Both groups showed a statistically significant improvement in functional variables at 3 months post operatively. The cost utility analysis for Holmium per case was 2589 euros versus 4706 per laparoscopic case. In the laser arm, 4 patients (20%) experienced complications according to the modified Clavien classification system versus 5 (25%) in the laparoscopic group (P>.99). Holmium enucleation of the prostate has similar short term functional results and complication rates compared to laparoscopic simple prostatectomy performed in large glands with the advantage of less catheterization time, lower economic costs and a reduced hospital stay. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.
Preliminary Experience with use of Qureshi-5 Catheters for Diagnostic Cerebral Angiography.
Qureshi, Adnan I; Yan, Xiao; Liu, HongLiang
2015-05-01
A catheter technique was developed to overcome current challenges in the stabilization and manipulation of catheter in tortuous arteries such as right subclavian artery and left common carotid artery. The new catheter has the following two lumens: first lumen can accommodate a 0.035-inch guide wire (lumen A) and a curved shape at the distal end; the second lumen can accommodate a 0.018-inch guide wire and terminates at the beginning of the distal curve of the first lumen (lumen B). The catheter is withdrawn or advanced over the 0.018-inch guide wire and the curved free end of catheter manipulated until the end engages the origin of the target artery. Subsequently, either contrast can be injected or a 0.035-inch guide wire advanced into the target artery. The catheters were used in two patients to perform diagnostic cerebral angiography through a 6F introducer sheath placed in the right common femoral artery. The left and right common carotid arteries and left and right vertebral arteries were catheterized in first patient (contrast used 50 ml; fluoroscopy time 20:09 min). The left and right internal carotid arteries, left and right subclavian arteries, and left external carotid artery were catheterized in second patient (contrast used 40 ml; fluoroscopy time 13:56 min). No complications were observed in either of the two patients. The performance of the new catheter for catheterization of multiple arteries in two patients was considered adequate with high-quality angiographic image acquisitions.
Opioid Abuse after Traumatic Brain Injury: Evaluation Using Rodent Models
2015-09-01
depending on the aspect of SA being assessed. This includes time for acclimation to the laboratory and handling, catheterization surgery and recovery, brain...across the three years / total number to be completed by project end. Total # subjects entered into protocol =50 Total number catheterized = 0...and acclimation before intravenous catheterization or pump implantation was performed (see below). Subjects to be used in the warm water tail
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tercan, Fahri; Oguzkurt, Levent; Ozkan, Ugur
2008-05-15
The purpose of this study was to compare the technical success and complication rates of ultrasonography-guided central venous catheterization between adult and pediatric patients which have not been reported previously. In a 4-year period, 859 ultrasonography-guided central vein catheterizations in 688 adult patients and 247 catheterizations in 156 pediatric patients were retrospectively evaluated. Mean age was 56.3 years (range, 18 to 95 years) for adults and 3.3 years (range, 0.1 to 16.3 years) for children. The preferred catheterization site was internal jugular vein in 97% of adults and 85% of children. The technical success rate, mean number of punctures, andmore » rate of single wall puncture were 99.4%, 1.04 (range, 1-3), and 83% for adults and 90.3%, 1.25 (range, 1-5), and 49% for children, respectively. All the differences were statistically significant (p < 0.05). Complication rates were 2.3% and 2.4% for adults and children, respectively (p > 0.05). Major complications such as pneumothorax and hemothorax were not seen in any group. In conclusion, ultrasonography-guided central venous catheterization has a high technical success rate, lower puncture attempt rate, and higher single wall puncture rate in adults compared to children. Complication rates are comparable in the two groups.« less
Wang, Kai; Pan, Xuanren; Tang, Qiaoyun; Pang, Yusheng
2014-03-01
Patent ductus arteriosus (PDA) remains a common congenital heart disease in pediatric patients, and the new trend of catheterization therapy is still associated with some potential risks and complications. Compared with surgical closure, the clinical effect of catheterization therapy in pediatric PDA patients requires meta-analysis. A systematic literature search of PubMed, Cochrane Library, Embase, Science Citation Index, Web of Science, and the Chinese Biomedicine literature database was conducted. Eligible studies included controlled trials of pediatric PDA patients receiving catheterization therapy vs surgical closure. Relative risks (RRs), standard mean differences, and 95% confidence intervals (CIs) were calculated and heterogeneity was assessed with the I(2) test. Seven studies with a total of 810 patients met the inclusion criteria. Catheterization therapy neither significantly increased the primary success rate (RR: 0.92, 95% CI: 0.82-1.03, P = 0.16) nor reduced the total postprocedure complications (RR: 0.74, 95% CI: 0.44-1.25, P = 0.26) and blood transfusion (RR: 1.10, 95% CI: 0.16-7.67, P = 0.93). Catheterization was associated with a statistically significant increase in residual shunts (RR: 5.19, 95% CI: 1.41-19.20, P = 0.01) and reduction in length of hospital stay (standard mean difference: -1.66, 95% CI: -2.65 to -0.67, P = 0.001). Catheterization therapy in pediatric PDA patients did not show a significant advantage in primary success rate, total complications, or blood transfusion, but it was associated with increase in residual shunts and reduction in length of hospital stay. © 2014 Wiley Periodicals, Inc.
Kari, Jameela; Al-Deek, Basem; Elkhatib, Lamis; Salahudeen, Sayed; Mukhtar, Najla; Al Ahmad, Rafif; Eldesoky, Sherif; Raboei, Enaam
2013-10-01
We aimed to examine the social impact of clean intermittent catheterization (CIC) on children with a neurogenic bladder and to compare the impact of urethral CIC with Mitrofanoff catheterization. Questionnaires containing 29 questions about the social impact of CIC on the children and their families were administered with their parents or caregivers of 50 children (34 boys and 16 girls) using CIC. The mean (standard deviation [SD]) age of the children was 9.6 (4.32) years and duration on CIC was 6.1 (3.97) years. Seventeen children were using Mitrofanoff catheterization (group I) and 33 children urethral catheterization (group II). Of the respondents, 54% respondents reported that their children accept the use of CIC, 30% respondents reported that they do not like it, and 16% respondents reported that they always refuse and resist it. There was no difference in the level of acceptance between the two groups. Both groups reported that children were social (90%) and had close friends (88%). However, 50% felt that CIC affected mood, with 30% of the children displaying bad temper. Mitrofanoff catheterization was associated with fewer episodes of frequent urinary tract infection (p = 0.004) and greater adherence. All children from group I, who were older than 6 years, were attending school compared with 78% from group II. School performance was significantly better in group I (p = 0.022). There was acceptance of CIC by most children but Mitrofanoff catheterization seemed to have a lower social impact in terms of school performance, adherence to therapy, and complications. Georg Thieme Verlag KG Stuttgart · New York.
Gurm, Hitinder S; Hosman, Carrie; Bates, Eric R; Share, David; Hansen, Ben B
2015-02-01
Eptifibatide, a small-molecule glycoprotein IIb/IIIa inhibitor, is conventionally administered as a bolus plus infusion. A growing number of clinicians are using a strategy of catheterization laboratory-only eptifibatide (an off-label use) as procedural pharmacotherapy for patients undergoing percutaneous coronary intervention although the comparative effectiveness of this approach is unknown. We compared the in-hospital outcome of patients undergoing percutaneous coronary intervention across 47 hospitals and treated with eptifibatide bolus plus infusion with those treated with a catheterization laboratory-only regimen. We used optimal matching to link the use of catheterization laboratory-only eptifibatide with clinical outcomes, including mortality, myocardial infarction, bleeding, and need for transfusion. Of the 84 678 percutaneous coronary interventions performed during 2010 to 2011, and meeting our inclusion criteria, eptifibatide was administered to 21 296 patients. Of these, a catheterization laboratory-only regimen was used in 4511 patients, whereas 16 785 patients were treated with bolus plus infusion. In the optimally matched analysis, compared with bolus plus infusion, a catheterization laboratory-only regimen was associated with a reduction in bleeding (optimally matched adjusted odds ratio, 0.74; 95% confidence interval, 0.58-0.93; P=0.014) and need for transfusion (optimally matched adjusted odds ratio, 0.70; 95% confidence interval, 0.52-0.92; P=0.012), with no difference in mortality or myocardial infarction. A catheterization laboratory-only eptifibatide regimen is commonly used in clinical practice and is associated with a significant reduction in bleeding complications in patients undergoing contemporary percutaneous coronary intervention. © 2015 American Heart Association, Inc.
Ziegler, M U; Reinelt, H
2018-05-01
Patients undergoing cardiac surgery need extensive and invasive monitoring, which needs to be individually adapted for each patient and requires a diligent risk-benefit analysis. The use of a pulmonary artery catheter (PAC) seems to be justifiable in certain cases; therefore, the preoperative diagnosis of pulmonary hypertension represents an indication for perioperative monitoring with PAC in the S3 guidelines of the German Society for Anesthesiology and Intensive Care Medicine (DGAI). In many cases, however, this preoperative diagnosis cannot be confirmed intraoperatively. We wanted to find out whether this is just an impression or whether there actually are significant differences between preoperative, intraoperative and postoperative pulmonary artery pressures. After obtaining ethical approval, we retrospectively compared the pulmonary pressures of cardiac surgery patients with an elevated pulmonary pressure during preoperative right heart catheterization with those obtained intraoperatively and postoperatively by means of a PAC. All patients with a preoperatively documented pulmonary artery pressure of 40 mmHg or above and an intraoperative use of a PAC during a 4-year period were included. Exclusion criteria were intracardiac shunts, cardiogenic shock, emergency procedures, pulmonary hypertension of non-cardiac origin and a time span of more than 1 year between right heart catheterization and surgery. We included 90 patients. In the whole group and in the subgroups (according to diagnosis, time elapsed between heart catheterization and operation and pulmonary pressure), there were significant differences between preoperative and intraoperative pulmonary and systemic pressures. Systemic and pulmonary artery pressures were significantly higher during preoperative catheterization than intraoperatively. The systemic systolic pressure/systolic pulmonary pressure ratio, however, remained constant. The intraoperative and postoperative systemic and pulmonary artery pressures showed no significant differences. As a normal ejection fraction does not exclude heart failure with preserved ejection fraction and as we did not have any information on this condition, we did not group the patients according to the ejection fraction. An elevated pulmonary pressure obtained preoperatively during right heart catheterization is not indicative of an elevated pulmonary pressure either intraoperatively or postoperatively. There are various explanations for the differences (e.g., different physiological and pathophysiological settings, such as sedation with potential hypercapnia versus anesthesia with vasodilation when measured; newly prescribed medication coming into effect between the right heart catheterization and surgery; intraoperative positioning). Even though the inherent risks of a PAC seem to be low, we recommend refraining from using a PAC in patients with a once documented elevated pulmonary pressure by default. As an alternative we suggest estimating the pulmonary pressure by transesophageal echocardiography (TEE) as an aid to decide whether the patient will benefit from the use of a PAC. Especially if it is not possible to identify tricuspid valve regurgitation for determining the peak gradient, it is helpful to check for additional signs of pulmonary hypertension. But we also have to bear in mind that in the postoperative period only a PAC can provide continuous measurement of pulmonary pressure.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-31
... Electronic Device (CIED) Procedures c. New Candidate HAC Condition: Iatrogenic Pneumothorax With Venous Catheterization 6. RTI Program Evaluation Summary a. RTI Analysis of FY 2011 POA Indicator Reporting Across.... Hospital Inpatient Quality Reporting (IQR) Program 1. Background a. History of Measures Adopted for the...
1985-12-01
catheterization prescribing birth control pills prescribing narcotics treating hypertension delivering babies treating post surgical cases assisting in surgery...catheterization -3 prescribing birth control 1;i 11 -4 treating victims of poisoning -5 doing physical exams for nuclear surety -6 prescribing narcotics -7...narrative summaries. o__ physica, exams for reieet o.. do urinary tract catheterization. administer local anesthesia. prescribe birth control pills
Hydrothorax after Central Venous Catheterization
Rudge, C. J.; Bewick, M.; McColl, I.
1973-01-01
Three patients are described who developed hydrothorax as a complication of central venous catheterization. Respiratory distress associated with physical signs of fluid in the chest should arouse suspicion that the venous catheter has perforated the wall of the vein. The complications of central venous catheterization are reviewed and three cases of hydrothorax are presented. Comments on the prevention of these complications, their diagnosis and treatment if they occur, are made. ImagesFIG. 1FIG. 2 PMID:4717421
Isn't it time to abandon cine film?
Holmes, D R; Wondrow, M A; Gray, J E
1990-05-01
Cine has served our needs well since the early 1950s. For the first time, it allowed recording of motion studies of the cardiac structures on film. The cine technique has been standardized over the years, both the camera and the display. Cine filming techniques, however, have not advanced, except for new film products with faster emulsions and better-quality films. Video electronic imaging has made rapid advancements. These were prompted by the broadcast industry when the requirements for color were developed in the 1960s and by the advent of new recording techniques that provided a very stable video time base from analog tape recorders. The medical field has been able to capitalize on these developments and to produce some of our own that have not been applied in the broadcast world. These include pulsed progressive 525-line video acquisition of cardiac images in the cardiac catheterization laboratory. We also have been able to capitalize on the improved detector technology that the broadcast world has developed, such as the plumbicon pickup tubes, which produce images with very little lag and so provide images with improved resolution. These developments also have enabled us to reduce radiation to both the patient and the laboratory personnel, especially with implementation of the pulsed progressive acquisition, with which the dose has been reduced 50%. With the advent of interventional procedures in the cardiac catheterization laboratory, the need to assess images immediately cannot be fulfilled by cine filming because of the requirement for the processing of the film with its inherent delays. Quantification of cardiac structures is required to assess the outcome of interventional techniques.(ABSTRACT TRUNCATED AT 250 WORDS)
Parienti, Jean-Jacques; Thirion, Marina; Mégarbane, Bruno; Souweine, Bertrand; Ouchikhe, Abdelali; Polito, Andrea; Forel, Jean-Marie; Marqué, Sophie; Misset, Benoît; Airapetian, Norair; Daurel, Claire; Mira, Jean-Paul; Ramakers, Michel; du Cheyron, Damien; Le Coutour, Xavier; Daubin, Cédric; Charbonneau, Pierre
2008-05-28
Based on concerns about the risk of infection, the jugular site is often preferred over the femoral site for short-term dialysis vascular access. To determine whether jugular catheterization decreases the risk of nosocomial complications compared with femoral catheterization. A concealed, randomized, multicenter, evaluator-blinded, parallel-group trial (the Cathedia Study) of 750 patients from a network of 9 tertiary care university medical centers and 3 general hospitals in France conducted between May 2004 and May 2007. The severely ill, bed-bound adults had a body mass index (BMI) of less than 45 and required a first catheter insertion for renal replacement therapy. Patients were randomized to receive jugular or femoral vein catheterization by operators experienced in placement at both sites. Rates of infectious complications, defined as catheter colonization on removal (primary end point), and catheter-related bloodstream infection. Patient and catheter characteristics, including duration of catheterization, were similar in both groups. More hematomas occurred in the jugular group than in the femoral group (13/366 patients [3.6%] vs 4/370 patients [1.1%], respectively; P = .03). The risk of catheter colonization at removal did not differ significantly between the femoral and jugular groups (incidence of 40.8 vs 35.7 per 1000 catheter-days; hazard ratio [HR], 0.85; 95% confidence interval [CI], 0.62-1.16; P = .31). A prespecified subgroup analysis demonstrated significant qualitative heterogeneity by BMI (P for the interaction term < .001). Jugular catheterization significantly increased incidence of catheter colonization vs femoral catheterization (45.4 vs 23.7 per 1000 catheter-days; HR, 2.10; 95% CI, 1.13-3.91; P = .017) in the lowest tercile (BMI <24.2), whereas jugular catheterization significantly decreased this incidence (24.5 vs 50.9 per 1000 catheter-days; HR, 0.40; 95% CI, 0.23-0.69; P < .001) in the highest tercile (BMI >28.4). The rate of catheter-related bloodstream infection was similar in both groups (2.3 vs 1.5 per 1000 catheter-days, respectively; P = .42). Jugular venous catheterization access does not appear to reduce the risk of infection compared with femoral access, except among adults with a high BMI, and may have a higher risk of hematoma. clinicaltrials.gov Identifier: NCT00277888.
... than usual ( oliguria ). You cannot urinate despite a strong urge to do so. Alternative Names Biopsy - bladder Images Bladder catheterization, female Bladder catheterization, male Female urinary tract Male urinary tract Bladder biopsy ...
Lyubarova, Radmila; Boden, William E; Fein, Steven A; Schulman-Marcus, Joshua; Torosoff, Mikhail
2018-06-01
Transthoracic echocardiography (TTE) has been used to assess coronary sinus blood flow (CSBF), which reflects total coronary arterial blood flow. Successful angioplasty is expected to improve coronary arterial blood flow. Changes in CSBF after percutaneous coronary intervention (PCI), as assessed by TTE, have not been systematically evaluated. TTE can be utilized to reflect increased CSBF after a successful, clinically indicated PCI. The study cohort included 31 patients (18 females, 62 ± 11 years old) referred for diagnostic cardiac catheterization for suspected coronary artery disease and possible PCI, when clinically indicated. All performed PCIs were successful, with good angiographic outcome. CSBF per cardiac cycle (mL/beat) was measured using transthoracic two-dimensional and Doppler flow imaging as the product of coronary sinus (CS) area and CS flow time-velocity integral. CSBF per minute (mL/min) was calculated as the product of heart rate and CSBF per cardiac cycle. In each patient, CSBF was assessed prospectively, before and after cardiac catheterization with and without clinically indicated PCI. Within- and between-group differences in CSBF before and after PCI were assessed using repeated measures analysis of variance. Technically adequate CSBF measurements were obtained in 24 patients (77%). In patients who did not undergo PCI, there was no significant change in CSBF (278.1 ± 344.1 versus 342.7 ± 248.5, p = 0.36). By contrast, among patients who underwent PCI, CSBF increased significantly (254.3 ± 194.7 versus 618.3 ± 358.5 mL/min, p < 0.01, p-interaction = 0.03). Other hemodynamic and echocardiographic parameters did not change significantly before and after cardiac catheterization in either treatment group. Transthoracic echocardiographic assessment can be employed to document CSBF changes after angioplasty. Future studies are needed to explore the clinical utility of this noninvasive metric.
Fukuoka, Kahoru; Furuichi, Mihoko; Ito, Kenta; Morikawa, Yoshihiko; Watanabe, Ichiro; Shimizu, Naoki; Horikoshi, Yuho
2018-06-13
Catheter-associated urinary tract infections account for 30% of healthcare-associated infections. To date, few studies have addressed pediatric catheter-associated urinary tract infection in PICUs. The aim of our study was to assess the risk of catheter-associated urinary tract infection in relation to the duration of catheterization in the PICU. Retrospective cohort study. PICU at a tertiary children's hospital. Our study was conducted between April 2012 and June 2015 at Tokyo Metropolitan Children's Medical Center in Japan. Children in the PICU with an urethral catheter were included. Catheter-associated urinary tract infection cases were defined according to the National Healthcare Safety Network criteria. The patients' demographic data and isolated organisms were reviewed. Duration of catheterization and the catheter-associated urinary tract infection occurrence rate were analyzed. None. Among 1,890 catheterizations, 23 catheter-associated urinary tract infection cases were identified. The overall occurrence rate was 2.35/1,000 catheter-days. Among the patients with catheter-associated urinary tract infection, 13 were boys. The median age was 11 months (interquartile range, 7-35 mo), and the median duration of catheterization was 7 days (interquartile range, 5-12 d). The isolated bacteria were Escherichia coli (26.5%), Enterococcus faecalis (17.6%), and Klebsiella pneumoniae (11.8%). Two species were isolated in each of 11 cases (47.8%). Each additional day of catheterization increased the risk of catheter-associated urinary tract infection (odds ratio, 1.06; 95% CI, 1.02-1.10, and odds ratio adjusted for contact precaution status and surgical procedures was 1.05; 95% CI, 1.01-1.09). Longer duration of catheterization increased the risk of catheter-associated urinary tract infection by 5% each day at the PICU. Prompt removal of the urethral catheter is strongly recommended whenever feasible.
Van Broeck, Bianca; Timmers, Maarten; Ramael, Steven; Bogert, Jennifer; Shaw, Leslie M; Mercken, Marc; Slemmon, John; Van Nueten, Luc; Engelborghs, Sebastiaan; Streffer, Johannes Rolf
2016-05-19
Cerebrospinal fluid (CSF) amyloid-beta (Aβ) peptides are predictive biomarkers for Alzheimer's disease and are proposed as pharmacodynamic markers for amyloid-lowering therapies. However, frequent sampling results in fluctuating CSF Aβ levels that have a tendency to increase compared with baseline. The impact of sampling frequency, volume, catheterization procedure, and ibuprofen pretreatment on CSF Aβ levels using continuous sampling over 36 h was assessed. In this open-label biomarker study, healthy participants (n = 18; either sex, age 55-85 years) were randomized into one of three cohorts (n = 6/cohort; high-frequency sampling). In all cohorts except cohort 2 (sampling started 6 h post catheterization), sampling through lumbar catheterization started immediately post catheterization. Cohort 3 received ibuprofen (800 mg) before catheterization. Following interim data review, an additional cohort 4 (n = 6) with an optimized sampling scheme (low-frequency and lower volume) was included. CSF Aβ(1-37), Aβ(1-38), Aβ(1-40), and Aβ(1-42) levels were analyzed. Increases and fluctuations in mean CSF Aβ levels occurred in cohorts 1-3 at times of high-frequency sampling. Some outliers were observed (cohorts 2 and 3) with an extreme pronunciation of this effect. Cohort 4 demonstrated minimal fluctuation of CSF Aβ both on a group and an individual level. Intersubject variability in CSF Aβ profiles over time was observed in all cohorts. CSF Aβ level fluctuation upon catheterization primarily depends on the sampling frequency and volume, but not on the catheterization procedure or inflammatory reaction. An optimized low-frequency sampling protocol minimizes or eliminates fluctuation of CSF Aβ levels, which will improve the capability of accurately measuring the pharmacodynamic read-out for amyloid-lowering therapies. ClinicalTrials.gov NCT01436188 . Registered 15 September 2011.
Wu, Wen-Chih; Waring, Molly E.; Lessard, Darleen; Yarzebski, Jorge; Gore, Joel; Goldberg, Robert J.
2011-01-01
Background It is unknown how anemia influences the invasive management of patients with non-ST-segment-elevation myocardial infarction (NSTEMI) and associated mortality. We investigated whether receipt of cardiac catheterization relates to 6-month death rates among patients with different severity of anemia. Methods We used data from the population-based Worcester Heart Attack Study, which included 2,634 patients hospitalized with confirmed NSTEMI, from 3 PCI-capable medical centers in the Worcester (MA) metropolitan area, during 5 biennial periods between 1997 and 2005. Severity of anemia was categorized using admission hematocrit levels: ≤30.0% (moderate-to-severe anemia), 30.1–39.0% (mild anemia), and >39.0% (no anemia). Propensity matching and conditional logistic regression adjusting for hospital use of aspirin, heparin, and plavix compared 6-month post-admission all-cause mortality rates in relation to cardiac catheterization during NSTEMI hospitalization. Results Compared to patients without anemia, patients with anemia were less likely to undergo cardiac catheterization (adjusted odds ratio [AOR] 0.79 [95% confidence interval [CI]: 0.67–0.95] for mild anemia and 0.45 [95%CI: 0.42–0.49] for moderate-to-severe anemia). After propensity matching, cardiac catheterization was associated with lower 6-month death rates only in patients without anemia (AOR 0.26 [95%CI: 0.09–0.79]) but not in patients with mild anemia (AOR 0.55 [95%CI: 0.25–1.23]). The small number of patients rendered data inconclusive for patients with moderate-to-severe anemia. Conclusions Anemia at the time of hospitalization for NSTEMI was associated with lower utilization of cardiac catheterization. However, cardiac catheterization use was associated with a decreased risk of dying at 6 months post hospital admission only in patients without anemia. PMID:21738102
Pitfalls of diagnosing urinary tract infection in infants and young children.
Yamasaki, Yasuhito; Uemura, Osamu; Nagai, Takuhito; Yamakawa, Satoshi; Hibi, Yoshiko; Yamamoto, Masaki; Nakano, Masaru; Kasahara, Katsuaki; Bo, Zhang
2017-07-01
The aim of this study was to examine the sensitivity and specificity of pyuria-based diagnosis of urinary tract infection (UTI) in urine collected by transurethral catheterization, and the reliability of diagnosis of pyuria in urine collected in a perineal bag. The gold standard for UTI diagnosis is significant colony counts of a single organism in urine obtained in a sterile manner. We enrolled 301 patients who underwent medical examination at the present hospital for possible UTI between January 2005 and December 2009. We collected 438 urine samples by transurethral catheterization. We investigated the accuracy of pyuria-based diagnosis of UTI using transurethral catheterization urine specimens, and the reliability of diagnosis of pyuria using bag-collected urine specimens. The false-negative rate of UTI diagnosis based on pyuria in transurethral catheterization urine sediments was 9.0%; there was no significant difference in the false-negative rate of UTI diagnosis between boys and girls. Approximately 28% of pyuria-positive bag-collected urine specimens were pyuria negative on transurethral catheterization; this rate was significantly higher in girls than in boys (56.7% vs. 8.9%, P < 0.0001). The absence of pyuria in transurethral catheterization urine sediments does not rule out UTI. Pyuria in bag-collected urine specimens frequently consists of urine leukocytes from external genitalia as well as from the urinary tract. © 2017 Japan Pediatric Society.
Chrischilles, Elizabeth; Schneider, Kathleen; Wilwert, June; Lessman, Gregory; O'Donnell, Brian; Gryzlak, Brian; Wright, Kara; Wallace, Robert
2014-03-01
Studies of patients with multiple chronic conditions using claims data are often missing important determinants of treatments and outcomes, such as function status and disease severity. We sought to identify and evaluate a class of function-related indicators (FRIs) from administrative claims data. The study cohort comprised US Medicare beneficiaries aged 65 years or older with Parts A and B fee-for-service and Part D coverage, with a hospitalization for acute myocardial infarction during 2007. Measures during the year before admission included the FRIs, demographics, conventional comorbidity measures, and prior hospitalization. Outcomes were receipt of cardiac catheterization during the index hospitalization and 12-month mortality. Model development used a random sample (n=72,056) with an equal sample for validation. In addition to prior cardiovascular conditions (85%), 40% had ≥1 comorbid condition, 30% were hospitalized in the prior 6 months, and 65% had ≥1 FRI [eg, delirium/dementia (22.7%), depression (16.7%), mobility limitation (16.1%), and chronic skin ulcers (12.6%)]. Including the FRIs improved mortality and cardiac catheterization prediction models (C-statistics 0.71 and 0.77, respectively). Patients with more cardiovascular conditions received less cardiac catheterization [minimally adjusted odds ratio (OR) 0.83; 95% confidence interval (CI), 0.82-0.83], as did patients with more comorbidities (minimally adjusted OR 0.70; 95% CI, 0.69-0.71), but this was attenuated by adjusting for functional status (fully adjusted OR for cardiovascular conditions 0.95; 95% CI, 0.94-0.96 and for comorbid conditions 0.94; 95% CI, 0.92-0.95). Claims data studies that include indicators of potentially diminished patient functional status better capture heterogeneity of patients with multiple chronic conditions.
Recent advances in managing vascular occlusions in the cardiac catheterization laboratory
Qureshi, Athar M.; Mullins, Charles E.; Latson, Larry A.
2018-01-01
Vascular occlusions continue to be a significant cause of morbidity and mortality. The management of vascular occlusions in patients is complex, requiring specialized expertise in the cardiac catheterization laboratory and from other disciplines. Knowledge of currently available tools at the operator’s disposal is important to optimize the success of these procedures. In this review, we discuss some of the recent advances in recanalization procedures of vascular occlusions and thrombotic lesions in the cardiac catheterization laboratory. PMID:29770200
Mulder, Femke E M; Hakvoort, Robert A; de Bruin, Jan P; van der Post, Joris A M; Roovers, Jan-Paul W R
2017-08-30
Overt postpartum urinary retention (PUR) is the inability to void after delivery and affects up to 7% of patients. Clean intermittent catheterization (CIC) and transurethral indwelling catheterization (TIC) are both standard treatments, but have not previously been compared. Clinical guidelines on postpartum bladder management are lacking. A total of 85 patients were randomised for TIC (n=45) and CIC (n=40). In total 68 patients (34 patients with TIC and 34 patients with CIC) completed the UDI-6 questionnaire 3 months after delivery.. Patients allocated to TIC received an indwelling catheter for 24 h and if necessary, another catheter for 48 h. Patients with CIC were intermittently catheterized or taught to self-catheterize until adequate voiding with a postvoid residual volume (PVRV) of <150 mL was achieved. The primary outcome was the presence of bothersome micturition symptoms as measured using the Dutch-validated Urogenital Distress Inventory (UDI-6). Only seven patients (10%) reported bothersome micturition problems 3 months after delivery. No significant differences in the occurrence of micturition symptoms were found. Median PVRV was 800 mL in the CIC group and 650 mL in the TIC group. PVRV was ≥1,000 mL in 24% of the patients. The median duration of catheterization was significantly shorter in the CIC group than in the TIC group (12 h vs. 24 h, p < 0,01). In patients with CIC, 35% required only one catheterization before complete bladder emptying occurred. The duration of treatment was not related to the initial PVRV. Both treatments were equally well accepted by the patients. In patients with overt PUR, CIC is the preferred treatment as a considerable percentage of patients appear to be over-treated when the standard duration of TIC is 24 h. The occurrence of micturition symptoms is not associated with the catheterization method used. CIC is well tolerated in patients with overt PUR.
Pikwer, Andreas; Acosta, Stefan; Kölbel, Tilo; Åkeson, Jonas
2010-01-01
This study was designed to assess endovascular intervention for central venous cannulation in patients with vascular occlusion after previous catheterization. Patients referred for endovascular management of central venous occlusion during a 42-month period were identified from a regional endovascular database, providing prospective information on techniques and clinical outcome. Corresponding patient records, angiograms, and radiographic reports were analyzed retrospectively. Sixteen patients aged 48 years (range 0.5-76), including 11 females, were included. All patients but 1 had had multiple central venous catheters with a median total indwelling time of 37 months. Eleven patients cannulated for hemodialysis had had significantly fewer individual catheters inserted compared with 5 patients cannulated for nutritional support (mean 3.6 vs. 10.2, p<0.001) before endovascular intervention. Preoperative imaging by magnetic resonance tomography (MRT) in 8 patients, computed tomography (CT) venography in 3, conventional angiography in 6, and/or ultrasonography in 8, verified 15 brachiocephalic, 13 internal jugular, 3 superior caval, and/or 3 subclavian venous occlusions. Patients were subjected to recanalization (n=2), recanalization and percutaneous transluminal angioplasty (n=5), or stenting for vena cava superior syndrome (n=1) prior to catheter insertion. The remaining 8 patients were cannulated by avoiding the occluded route. Central venous occlusion occurs particularly in patients under hemodialysis and with a history of multiple central venous catheterizations with large-diameter catheters and/or long total indwelling time periods. Patients with central venous occlusion verified by CT or MRT venography and need for central venous access should be referred for endovascular intervention.
Preliminary Experience with use of Qureshi-5 Catheters for Diagnostic Cerebral Angiography
Qureshi, Adnan I.; Yan, Xiao; Liu, HongLiang
2015-01-01
BACKGROUND A catheter technique was developed to overcome current challenges in the stabilization and manipulation of catheter in tortuous arteries such as right subclavian artery and left common carotid artery. METHODS The new catheter has the following two lumens: first lumen can accommodate a 0.035-inch guide wire (lumen A) and a curved shape at the distal end; the second lumen can accommodate a 0.018-inch guide wire and terminates at the beginning of the distal curve of the first lumen (lumen B). The catheter is withdrawn or advanced over the 0.018-inch guide wire and the curved free end of catheter manipulated until the end engages the origin of the target artery. Subsequently, either contrast can be injected or a 0.035-inch guide wire advanced into the target artery. RESULTS The catheters were used in two patients to perform diagnostic cerebral angiography through a 6F introducer sheath placed in the right common femoral artery. The left and right common carotid arteries and left and right vertebral arteries were catheterized in first patient (contrast used 50 ml; fluoroscopy time 20:09 min). The left and right internal carotid arteries, left and right subclavian arteries, and left external carotid artery were catheterized in second patient (contrast used 40 ml; fluoroscopy time 13:56 min). No complications were observed in either of the two patients. CONCLUSIONS The performance of the new catheter for catheterization of multiple arteries in two patients was considered adequate with high-quality angiographic image acquisitions. PMID:26060529
Do Physicians Do What They Say?
Wennberg, David E; Dickens, John D; Biener, Lois; Fowler, Floyd J; Soule, David N; Keller, Robert B
1997-01-01
OBJECTIVE Efforts to evaluate variations in cardiac procedures have focused on patient factors and differences in health care delivery systems. We wanted to assess how physicians’ inclination to test patients with coronary artery disease influences utilization patterns. SETTING AND SUBJECTS Physicians and the populations of Maine, New Hampshire, and Vermont. DESIGN We conducted a survey of 263 family practitioners, internists, and cardiologists residing in 57 hospital service areas in Maine, New Hampshire, and Vermont. Using patient scenarios, we assessed the clinicians’ inclinations to test during the evaluation of patients with coronary artery disease. Self-reported testing intensities were used to create three indices: a Catheterization Index, an Imaging Exercise Tolerance Test (ETT) Index, and a Nonimaging ETT Index. Using administrative data, age- and gender-adjusted population-based coronary angiography rates were calculated. Physicians were assigned to low (2.9/1,000), average (4.2/1,000), and high (5.8/1,000) coronary angiography rate areas, based on where they practice. Analysis of variance techniques were used to assess the relation of the index scores to the population-based coronary angiography rates and to physician specialties. RESULTS There was a positive relationship between the population-based coronary angiography rates and the self-reported scores of the Catheterization Index (p < .005) and the Imaging ETT Index (p = .01), but none was found for the Nonimaging ETT Index (p = .10). These relationships were evident in subanalyses of cardiologists and internists, but not of family practitioners. CONCLUSIONS Self-reported testing intensity by physicians is related to the population-based rates of coronary angiography. This relationship cuts across specialties, suggesting that there is a “medical signature” for the evaluation of patients with coronary artery disease.
... UTI; Health care-associated UTI; Catheter-associated bacteriuria; Hospital acquired-UTI Images Bladder catheterization, female Bladder catheterization, male References Calfee DP. Prevention and control of health care-associated infections. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...
Bladder catheterization, male (image)
... kept empty (decompressed) and urinary flow assured. The balloon holds the catheter in place for a duration of time. Catheterization in males is slightly more difficult and uncomfortable than in females because of the longer urethra.
Catheterization - left heart ... to help guide the catheters up into your heart and arteries. Dye (sometimes called "contrast") will be ... in the blood vessels that lead to your heart. The catheter is then moved through the aortic ...
Systemic Embolic Complications of Pulmonary Vein Angioplasty in Children.
Esch, Jesse J; Porras, Diego; Bergersen, Lisa; Jenkins, Kathy J; Marshall, Audrey C
2015-10-01
Pulmonary vein stenosis (PVS) carries significant morbidity and mortality for affected children, and its management often requires multiple angioplasty procedures. PVS angioplasty can be complicated by systemic embolic events such as stroke, but incidence and risk factors are poorly understood. We reviewed pediatric catheterizations involving PVS angioplasty and/or stent placement performed at Boston Children's Hospital between July 2005 and February 2014. A total of 406 cases were performed in 144 distinct patients. Patients underwent a median of two catheterizations, at median age 1 year and weight 6.9 kg. Eleven (2.7 %) catheterizations were complicated by clinically apparent systemic embolic events, comprising 10 strokes (one with associated hepatic embolism) and 1 renal infarct. Prevalence of clinically evident stroke among this cohort was 7.6 %. Using a prior (uncomplicated) catheterization to allow each patient to serve as their own control, we sought to identify potentially modifiable risk factors for systemic embolic events. Although this analysis was limited by low power, complicated and uncomplicated angioplasties did not appear to differ in case time, contrast dose, anticoagulation management, use of cutting balloons, number of catheter exchanges, or size of long sheath used. Significant non-embolic adverse events were common, occurring in 25 % of catheterizations. Systemic embolism appears to complicate PVS angioplasty at a rate much higher than that described for other congenital catheterizations. This risk may be inherent to the procedure rather than related to any modifiable or operator-dependent factors.
Percutaneous Catheterization of the Internal Jugular Vein for Hemodialysis
Yeum, Chung Ho; Kim, Soo Wan; Nah, Myong Yun; Ma, Seong Kwon; Ko, Jung Hee; Kim, Nam Ho; Choi, Ki Chul
2001-01-01
Objectives The present study was aimed at evaluating the clinical experiences in the internal jugular venous catheterization for hemodialysis. Methods We retrospectively analyzed the data on internal jugular venous catheterization at Chonnam National University Hospital from May 2000 to Februrary 2001. Results There were 132 uremic patients with a total of 150 attempts of internal jugular cannulation. Overall success rate was 90.9% with average puncture trials of 2.3±2.1. 124 (82.7%) of the catheterization attempts were made on the right side and 26 (17.3%) were made on the left. The catheters were left in place from 2 to 87 days with an average of 19.5±15.3 days per catheter. The dialysis sessions per catheter were from 2 to 58 with an average of 11.3±6.8. The mean blood flow during hemodialysis immediately after catheterization was 213.4±42.2 ml/min. Thirty two (21.3%) patients had early complications. These included carotid artery puncture (11.3%), local bleeding (4.7%), local pain (3.3%), neck hematoma (0.7%) and malposition of the catheter (1.3%). Seventeen (11.3%) patients had late complications. These included fever or infection (11.3%), inadequate blood flow rate (3.3%) and inadvertent withdrawal (2.0%). There was no catheter-related mortality. Conclusions Our experiences revealed that the internal jugular vein catheterization is relatively safe and efficient for temporary vascular access for hemodialysis. PMID:11855153
Worasuwannarak, Surapong; Pornratanarangsi, Suwatchai
2010-01-01
To assess a role of volume-to-creatinine clearance ratio (V/CrCl) and iodine dose-to-creatinine clearance ratio (I-dose/CrCl) in predicting contrast- induced nephropathy (CIN) in diabetic patients undergoing elective cardiac catheterization or percutaneous coronary intervention (PCI). In diabetic patients undergoing cardiac catheterization or PCI, the incidence of CIN is higher than in non-diabetic patients. High doses of contrast media also increase the likelihood of renal dysfunction. The ratio of the volume of contrast media to creatinine clearance (V/CrCl) and iodine dose-to-creatinine clearance (I-dose/CrCl) has been shown to correlate with the area under the curve of contrast media concentration over time and was used to predict the occurrence of CIN in unselected patients. No study has been conducted specifically in diabetic patients undergoing cardiac catheterization or PCI before. We conducted a prospective, single center study. The V/CrCl and I-dose/CrCl were calculated in diabetic patients undergoing elective cardiac catheterization or PCI. An increase in serum creatinine of > 0.5 mg/dl or > 25% by 7 days from baseline was considered CIN. The incidence of CIN was determined. The predictive value of V/CrCl and I-dose/CrCl for CIN were assessed using multivariable logistic regression. The total number of patients that had been enrolled in the study was 248; Male 50.8%. The overall incidence of CIN was 5.2%. The mean age for the entire population was 65 +/- 9 years; the mean body mass index was 25.6 +/- 4.0 kg/m2; and the mean creatinine clearance was 60.6 +/- 27.4 ml/min. The mean values of V/CrCl for patients with and without CIN were 3.7 +/- 2.9 and 2.2 +/- 1.7 (p = 0.041). The mean values of I-dose/CrCl for patients with and without CIN were 1.31 +/- 0.94 and 0.82 +/- 0.63 (p = 0.042). The receiver-operator characteristic curve analysis indicated that a V/CrCl ratio of 2.60 and I-dose/CrCl of 0.98 were fair predictors of CIN. After adjusting for other known predictors of CIN, a V/CrCl ratio > or = 2.60 remained the only significant predictor of CIN (Odds ratio 5.8; 95% confidence interval 1.7-19.4, p = 0.005). A V/CrCl ratio > or = 2.60 was a significant predictor of CIN in diabetic patients undergoing elective cardiac catheterization or PCI.
Ko, Dennis T; Tu, Jack V; Austin, Peter C; Wijeysundera, Harindra C; Samadashvili, Zaza; Guo, Helen; Cantor, Warren J; Hannan, Edward L
2013-07-10
Prior studies have shown that physicians in New York State (New York) perform twice as many cardiac catheterizations per capita as those in Ontario for stable patients. However, the role of patient selection in these findings and their implications for detection of obstructive coronary artery disease (CAD) are largely unknown. To evaluate the extent of obstructive CAD and to compare the probability of detecting obstructive CAD for patients undergoing cardiac catheterization. An observational study was conducted involving patients without a history of cardiac disease who underwent elective cardiac catheterization between October 1, 2008, and September 30, 2011. Obstructive CAD was defined as diameter stenosis of 50% or more in the left main coronary artery or stenosis of 70% or more in a major epicardial vessel. Observed rates and predicted probabilities of obstructive CAD. Predicted probabilities were estimated using logistic regression models. A total of 18,114 patients from New York and 54,933 from Ontario were included. The observed rate of obstructive CAD was significantly lower in New York at 30.4% (95% CI, 29.7%-31.0%) than in Ontario at 44.8% (95% CI, 44.4%-45.3%; P < .001). The percentage of patients with left main or 3-vessel CAD was also significantly lower in New York than in Ontario (7.0% [95% CI, 6.6%-7.3%] vs 13.0% [95% CI, 12.8%-13.3%]; P < .001). In New York, a substantially higher percentage of patients with low predicted probability of obstructive CAD underwent cardiac catheterization; for example, only 19.3% (95% CI, 18.7%-19.9%) of patients undergoing cardiac catheterization in New York had a greater than 50% predicted probability of having obstructive CAD than those in Ontario at 41% (95% CI, 40.6%-41.4%; P < .001). At 30 days, crude mortality for patients undergoing cardiac catheterization was slightly higher in New York at 0.65% (90 of 13,824; 95% CI, 0.51%-0.78%) than in Ontario at 0.38% (153 of 40,794; 95% CI, 0.32%-0.43%; P < .001). In Ontario compared with New York State, patients undergoing elective cardiac catheterization were significantly more likely to have obstructive CAD. This appears to be related to a higher percentage of patients in New York with low predicted probability of CAD undergoing cardiac catheterization.
Petrosal sinus sampling: technique and rationale.
Miller, D L; Doppman, J L
1991-01-01
Bilateral simultaneous sampling of the inferior petrosal sinuses is an extremely sensitive, specific, and accurate test for diagnosing Cushing disease and distinguishing between that entity and the ectopic ACTH syndrome. It is also valuable for lateralizing small hormone-producing adenomas within the pituitary gland. The inferior petrosal sinuses connect the cavernous sinuses with the ipsilateral internal jugular veins. The anatomy of the anastomoses between the inferior petrosal sinus, the internal jugular vein, and the venous plexuses at the base of the skull varies, but it is almost always possible to catheterize the inferior petrosal sinus. In addition, variations in size and anatomy are often present between the two inferior petrosal sinuses in a patient. Advance preparation is required for petrosal sinus sampling. Teamwork is a critical element, and each member of the staff should know what he or she will be doing during the procedure. The samples must be properly labeled, processed, and stored. Specific needles, guide wires, and catheters are recommended for this procedure. The procedure is performed with specific attention to the three areas of potential technical difficulty: catheterization of the common femoral veins, crossing the valve at the base of the left internal jugular vein, and selective catheterization of the inferior petrosal sinuses. There are specific methods for dealing with each of these areas. The sine qua non of correct catheter position in the inferior petrosal sinus is demonstration of reflux of contrast material into the ipsilateral cavernous sinus. Images must always be obtained to document correct catheter position. Special attention must be paid to two points to prevent potential complications: The patient must be given an adequate dose of heparin, and injection of contrast material into the inferior petrosal sinuses and surrounding veins must be done gently and carefully. When the procedure is performed as outlined, both inferior petrosal sinuses can be catheterized in more than 98% of patients. The complication rate is low, and the theoretical risk of major morbidity or death is less than 1% (neither has yet occurred, to our knowledge). The most common complication is groin hematoma.
Ma, Irene W Y; Zalunardo, Nadia; Brindle, Mary E; Hatala, Rose; McLaughlin, Kevin
2015-09-01
Blinded assessments of technical skills using video-recordings may offer more objective assessments than direct observations. This study seeks to compare these two modalities. Two trained assessors independently assessed 18 central venous catheterization performances by direct observation and video-recorded assessments using two tools. Although sound quality was deemed adequate in all videos, portions of the video for wire handling and drape handling were frequently out of view (n = 13, 72% for wire-handling; n = 17, 94% for drape-handling). There were no differences in summary global rating scores, checklist scores, or pass/fail decisions for either modality (p > 0.05). Inter-rater reliability was acceptable for both modalities. Of the 26 discrepancies identified between direct observation and video-recorded assessments, three discrepancies (12%) were due to inattention during video review, while one (4%) discrepancy was due to inattention during direct observation. In conclusion, although scores did not differ between the two assessment modalities, techniques of video-recording may significantly impact individual items of assessments. © The Author(s) 2014.
Clarençon, Frédéric; Wyse, Gerald; Fanning, Noel; Di Maria, Federico; Gaston, André; Chiras, Jacques; Sourour, Nader
2013-06-01
The use of flow-diverting stents has gained acceptance during the past few years for the treatment of numerous intracranial aneurysms, especially large or giant ones. However, successful catheterization of the distal parent artery in giant intracranial aneurysms with a microcatheter can be extremely challenging. Forming a microcatheter loop in the aneurysm sac can aid distal catheterization. We report the use of a Solitaire FR stent as an adjunctive tool in the successful treatment of 2 giant intracranial unruptured aneurysms with a Pipeline Embolization Device. After having formed a loop inside the aneurysm sac, the microcatheter was anchored distally by a Solitaire FR stent. With the Solitaire FR device opened, the loop in the giant aneurysm sac was completely reduced without loss of the microcatheter position in the distal parent artery. A Pipeline Embolization Device could be delivered in both cases without any difficulty. There were no complications. The technique described results in ideal microcatheter alignment with a secure distal position before deployment of a flow-diverting stent.
Shapiro, M; Ollenschleger, M D; Baccin, C; Becske, T; Spiegel, G R; Wang, Y; Song, X; Raz, E; Zumofen, D; Potts, M B; Nelson, P K
2015-11-01
Foreign material emboli following cerebral, cardiac, and peripheral catheterizations have been reported since the mid-1990s. Catheter coatings have been frequently implicated. The most recent surge of interest in this phenomenon within the neurointerventional community is associated with procedures using flow-diversion devices for the treatment of cerebral aneurysms. Following coil-supported Pipeline embolization in 4 cases and stent-supported coiling in 1, 5 patients developed multiple subcentimeter enhancing lesions, usually with surrounding edema and variable magnetic susceptibility in the vascular territories of the treated aneurysms. Conventional angiography findings were unrevealing. Laboratory work-up showed mild CSF protein elevation with no leukocytosis. Brain biopsy in 2 cases revealed granulomatous angiitis encasing foreign material, identical in stain appearance to a polyvinylpyrrolidone catheter coating. Corticosteroid administration typically produced clinical improvement. A heterogeneous radiographic and clinical course was noted, with rise and fall in the number of enhancing lesions in 2 patients and persistence in others. The etiology may be related to widespread adoption of increasingly sophisticated catheterization techniques. © 2015 by American Journal of Neuroradiology.
Managing Inadvertent Arterial Catheterization During Central Venous Access Procedures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nicholson, Tony, E-mail: Tony.Nicholson@leedsth.nhs.uk; Ettles, Duncan; Robinson, Graham
2004-01-15
Purpose: Approximately 200,000 central venous catheterizations are carried out annually in the National Health Service in the United Kingdom. Inadvertent arterial puncture occurs in up to 3.7%. Significant morbidity and death has been reported. We report on our experience in the endovascular treatment of this iatrogenic complication. Methods: Retrospective analysis was carried out of 9 cases referred for endovascular treatment of inadvertent arterial puncture during central venous catheterization over a 5 year period. Results: It was not possible to obtain accurate figures on the numbers of central venous catheterizations carried out during the time period. Five patients were referred withmore » carotid or subclavian pseudoaneurysms and hemothorax following inadvertent arterial catheter insertion and subsequent removal. These patients all underwent percutaneous balloon tamponade and/or stent-graft insertion. More recently 4 patients were referred with the catheter still in situ and were successfully treated with a percutaneous closure device. Conclusion: If inadvertent arterial catheterization during central venous access procedures is recognized and catheters removed, sequelae can be treated percutaneously. However, once the complication is recognized it is better to leave the catheter in situ and seal the artery percutaneously with a closure device.« less
Vapnek, Jonathan M; Maynard, Frederick M; Kim, Jiensup
2003-03-01
We compared the incidence of hematuria, pyuria and clinical urinary tract infection in patients who performed intermittent self-catheterization using a hydrophilic coated LoFric (Astra Tech AB, Mölndal, Sweden) or standard plastic catheter. A total of 62 male patients who performed intermittent self-catheterization to manage neurogenic bladder were randomized into 2 treatment groups at 3 American study sites. Outcome measures included urinary tract infection, microhematuria, pyuria and satisfaction rates. Of the 62 enrolled patients 49 completed the 12-month study. The withdrawal rate was not different in the 2 groups. At the end of the study there was statistically significantly less hematuria in the hydrophilic coated catheter group compared with controls. In addition, there was a significant decrease in the urinary tract infection rate from baseline in the hydrophilic coated catheter group but not in controls. Use of the hydrophilic coated catheter by patients on intermittent self-catheterization is associated with less hematuria and a significant decrease in the incidence of urinary tract infections. Therefore, it may be preferable for some patients, especially those with a history of difficult catheterization, urethral trauma or a high rate of urinary tract infection.
Ahn, J H; Kim, I S; Shin, K M; Kang, S S; Hong, S J; Park, J H; Kim, H J; Lee, S H; Kim, D Y; Jung, J H
2016-03-01
Real-time ultrasound-guided infraclavicular proximal axillary venous catheterization is used in many clinical situations and provides the advantages of catheter stabilization, a reduced risk of catheter-related infection, and comfort for the patient without limitation of movement. However, unintended catheter tip dislocation and accidental arterial puncture occur occasionally. This study was designed to investigate the influence of arm position on catheter placement and complications. Patients were randomized to either the neutral group (n=240) or the abduction group (n=241). In the neutral group, patients were positioned with the head and shoulders placed in an anatomically neutral position and the arms kept by the side during catheterization. In the abduction group, the right upper arm was abducted at 90° from the trunk during catheterization. After real-time ultrasound-guided catheterization was carried out in the right infraclavicular proximal axillary vein, misplacement of the catheter and all complications were evaluated with ultrasound and chest radiography. The success rate of complete catheterization before evaluating the placement of the catheter was high in both groups (97.1 vs 98.8%, P=not significant). The incidence of accidental arterial puncture was not different (1.7 vs 0%, P=not significant). The incidence of misplacement of the catheter was higher in the neutral group than in the abduction group (3.9 vs 0.4%, P=0.01). There were no complications, such as haemothorax, pneumothorax, or injury to the brachial plexus and phrenic nerve, in either group. Upper arm abduction may minimize the risk of misplacement of the catheter during real-time ultrasound-guided infraclavicular proximal axillary venous catheterization. The trial was registered with the Clinical Trial Registry of Korea: https://cris.nih.go.kr/cris/index.jsp. Identifier: KCT0001417. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Treatment of severe pulmonary hypertension in the setting of the large patent ductus arteriosus.
Niu, Mary C; Mallory, George B; Justino, Henri; Ruiz, Fadel E; Petit, Christopher J
2013-05-01
Treatment of the large patent ductus arteriosus (PDA) in the setting of pulmonary hypertension (PH) is challenging. Left patent, the large PDA can result in irreversible pulmonary vascular disease. Occlusion, however, may lead to right ventricular failure for certain patients with severe PH. Our center has adopted a staged management strategy using medical management, noninvasive imaging, and invasive cardiac catheterization to treat PH in the presence of a large PDA. This approach determines the safety of ductal closure but also leverages medical therapy to create an opportunity for safe PDA occlusion. We reviewed our experience with this approach. Patients with both severe PH and PDAs were studied. PH treatment history and hemodynamic data obtained during catheterizations were reviewed. Repeat catheterizations, echocardiograms, and clinical status at latest follow-up were also reviewed. Seven patients had both PH and large, unrestrictive PDAs. At baseline, all patients had near-systemic right ventricular pressures. Nine catheterizations were performed. Two patients underwent 2 catheterizations each due to poor initial response to balloon test occlusion. Six of 7 patients exhibited subsystemic pulmonary pressures during test occlusion and underwent successful PDA occlusion. One patient did not undergo PDA occlusion. In follow-up, 2 additional catheterizations were performed after successful PDA occlusion for subsequent hemodynamic assessment. At the latest follow-up, the 6 patients who underwent PDA occlusion are well, with continued improvement in PH. Five patients remain on PH treatment. A staged approach to PDA closure for patients with severe PH is an effective treatment paradigm. Aggressive treatment of PH creates a window of opportunity for PDA occlusion, echocardiography assists in identifying the timing for closure, and balloon test occlusion during cardiac catheterization is critical in determining safety of closure. By safely eliminating the large PDA, this treatment algorithm can halt the perilous combination of the large shunting from the PDA and PH in a population at high risk of morbidity and mortality.
78 FR 7967 - Revised Medical Criteria for Evaluating Respiratory System Disorders
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-04
... catheterization to include 40 mm Hg based on a recommendation by the Institute of Medicine in its report... than cardiac catheterization. Thus, the proposed listing would help us to adjudicate some cases more...
Interventional Radiology: Equipment and Techniques.
Scansen, Brian A
2016-05-01
The breadth of small animal diseases that can now be treated by a minimally invasive, transcatheter approach continues to expand. Interventional radiology is the field of medicine that affects a therapeutic outcome via minimally invasive catheterization of peripheral blood vessels or body orifices guided by imaging. The intent of this article is to provide an overview of the equipment required for interventional radiology in veterinary medicine with a discussion of technical uses in diseases of dogs and cats. Copyright © 2016 Elsevier Inc. All rights reserved.
Two-Step Process for ED UTI Screening in Febrile Young Children: Reducing Catheterization Rates.
Lavelle, Jane M; Blackstone, Mercedes M; Funari, Mary Kate; Roper, Christine; Lopez, Patricia; Schast, Aileen; Taylor, April M; Voorhis, Catherine B; Henien, Mira; Shaw, Kathy N
2016-07-01
Urinary tract infection (UTI) screening in febrile young children can be painful and time consuming. We implemented a screening protocol for UTI in a high-volume pediatric emergency department (ED) to reduce urethral catheterization, limiting catheterization to children with positive screens from urine bag specimens. This quality-improvement initiative was implemented using 3 Plan-Do-Study-Act cycles, beginning with a small test of the proposed change in 1 ED area. To ensure appropriate patients received timely screening, care teams discussed patient risk factors and created patient-specific, appropriate procedures. The intervention was extended to the entire ED after providing education. Finally, visual cues were added into the electronic health record, and nursing scripts were developed to enlist family participation. A time-series design was used to study the impact of the 6-month intervention by using a p-chart to determine special cause variation. The primary outcome measure for the study was defined as the catheterization rate in febrile children ages 6 to 24 months. The ED reduced catheterization rates among febrile young children from 63% to <30% over a 6-month period with sustained results. More than 350 patients were spared catheterization without prolonging ED length of stay. Additionally, there was no change in the revisit rate or missed UTIs among those followed within the hospital's network. A 2-step less-invasive process for screening febrile young children for UTI can be instituted in a high-volume ED without increasing length of stay or missing cases of UTI. Copyright © 2016 by the American Academy of Pediatrics.
Goreczny, Sebastian; Dryzek, Pawel; Morgan, Gareth J; Lukaszewski, Maciej; Moll, Jadwiga A; Moszura, Tomasz
2017-08-01
We report initial experience with novel three-dimensional (3D) image fusion software for guidance of transcatheter interventions in congenital heart disease. Developments in fusion imaging have facilitated the integration of 3D roadmaps from computed tomography or magnetic resonance imaging datasets. The latest software allows live fusion of two-dimensional (2D) fluoroscopy with pre-registered 3D roadmaps. We reviewed all cardiac catheterizations guided with this software (Philips VesselNavigator). Pre-catheterization imaging and catheterization data were collected focusing on fusion of 3D roadmap, intervention guidance, contrast and radiation exposure. From 09/2015 until 06/2016, VesselNavigator was applied in 34 patients for guidance (n = 28) or planning (n = 6) of cardiac catheterization. In all 28 patients successful 2D-3D registration was performed. Bony structures combined with the cardiovascular silhouette were used for fusion in 26 patients (93%), calcifications in 9 (32%), previously implanted devices in 8 (29%) and low-volume contrast injection in 7 patients (25%). Accurate initial 3D roadmap alignment was achieved in 25 patients (89%). Six patients (22%) required realignment during the procedure due to distortion of the anatomy after introduction of stiff equipment. Overall, VesselNavigator was applied successfully in 27 patients (96%) without any complications related to 3D image overlay. VesselNavigator was useful in guidance of nearly all of cardiac catheterizations. The combination of anatomical markers and low-volume contrast injections allowed reliable 2D-3D registration in the vast majority of patients.
Wilde, Mary H; Brasch, Judith; Zhang, Yi
2011-06-01
The study was to identify and describe issues of intermittent urinary catheter users for future self-management research and/or training programmes. Limited studies were found of how people using clean intermittent catheterization manage their daily routines or troubleshoot problems. Self-management research related to intermittent catheterization could lead to improved compliance with the method and better quality of life. This qualitative descriptive study involved in-depth tape-recorded telephone interviews in 2008-2009 with 34 people in the United States of America using permanent intermittent catheterization, mostly individuals with spinal cord injury or multiple sclerosis. Recruitment was through Internet sites where individuals could link to the study website and then contact the researchers. The sample included 13 men and 21 women aged 21-72 years (mean 42 years). Content analysis for qualitative data involved iterative comparisons of transcripts, summaries and memos. Coding, key quotes and tables were developed to determine themes. Six major themes were identified: Knowing the Body, Practising Intermittent Catheterization, Limited Options in Catheters and Equipment, Inaccessible Bathrooms, Hassles, and Adjustment in Making Intermittent Catheterization a Part of Life. While some persons had choices in catheters, many did not because of insurance constraints. Some individuals developed knowledge of how to balance the procedure with fluid intake and activities. The lack of acceptable bathrooms can interfere with being able to go to work, travel or be with friends and family. All using intermittent catheterization should have adequate insurance coverage when this is needed. Research into training programmes could incorporate knowledge of experienced users. © 2011 Blackwell Publishing Ltd.
Tait, Alan R; Voepel-Lewis, Terri; Moscucci, Mauro; Brennan-Martinez, Colleen M; Levine, Robert
2009-11-09
Several studies suggest that standard verbal and written consent information for treatment is often poorly understood by patients and their families. The present study examines the effect of an interactive computer-based information program on patients' understanding of cardiac catheterization. Adult patients scheduled to undergo diagnostic cardiac catheterization (n = 135) were randomized to receive details about the procedure using either standard institutional verbal and written information (SI) or interactive computerized information (ICI) preloaded on a laptop computer. Understanding was measured using semistructured interviews at baseline (ie, before information was given), immediately following cardiac catheterization (early understanding), and 2 weeks after the procedure (late understanding). The primary study outcome was the change from baseline to early understanding between groups. Subjects randomized to the ICI intervention had significantly greater improvement in understanding compared with those who received the SI (net change, 0.81; 95% confidence interval, 0.01-1.6). Significantly more subjects in the ICI group had complete understanding of the risks of cardiac catheterization (53.6% vs 23.1%) (P = .001) and options for treatment (63.2% vs 46.2%) (P = .048) compared with the SI group. Several predictors of improved understanding were identified, including baseline knowledge (P < .001), younger age (P = .002), and use of the ICI (P = .003). Results suggest that an interactive computer-based information program for cardiac catheterization may be more effective in improving patient understanding than conventional written consent information. This technology, therefore, holds promise as a means of presenting understandable detailed information regarding a variety of medical treatments and procedures.
Mahan, Angel F; McEvoy, Matthew D; Gravenstein, Nikolaus
2016-04-01
In modern practice, real-time ultrasound guidance is commonly employed for the placement of internal jugular vein catheters. With a new tool, such as ultrasound, comes the opportunity to refine and further optimize the ultrasound view during jugular vein catheterization. We describe jugular vein access techniques and use the long-axis view as an alternative to the commonly employed short-axis cross-section view for internal jugular vein access and cannulation. The long-axis ultrasound-guided internal jugular vein approach for internal jugular vein cannulation is a useful alternative technique that can provide better needle tip and guidewire visualization than the more traditional short-axis ultrasound view.
History of Right Heart Catheterization: 100 Years of Experimentation and Methodology Development
Nossaman, Bobby D.; Scruggs, Brittni A.; Nossaman, Vaughn E.; Murthy, Subramanyam N.; Kadowitz, Philip J.
2010-01-01
The development of right heart catheterization has provided the clinician the ability to diagnose patients with congenital and acquired right heart disease, and to monitor patients in the ICU with significant cardiovascular illnesses. The development of bedside pulmonary artery catheterization has become a standard of care for the critically ill patient since its introduction into the ICU almost 40 years ago. However, adoption of this procedure into the mainstream of clinical practice occurred without prior evaluation or demonstration of its clinical or cost-effectiveness. Moreover, current randomized, controlled trials provide little evidence in support of the clinical utility of pulmonary artery catheterization in the management of critically ill patients. Nevertheless, the right heart catheter is an important diagnostic tool to assist the clinician in the diagnosis of congenital heart disease and acquired right heart disease, and moreover, when catheter placement is proximal to the right auricle (atria), this catheter provides an important and safe route for administration of fluids, medications, and parenteral nutrition. The purpose of this manuscript is to review the development of right heart catheterization that led to the ability to conduct physiologic studies in cardiovascular dynamics in normal individuals and in patients with cardiovascular diseases, and to review current controversies of the extension of the right heart catheter, the pulmonary artery catheter. PMID:20160536
[Reducing urinary catheter use in patients hospitalized in internal medicine departments].
Shimoni, Zvi
2014-07-01
Clinical utility exists in certain situations for introducing a urinary catheter, but its use is the major cause of in-hospitaL acquired urinary tract infections. Furthermore, there are other complications of urinary catheterization, including urethral injury, macroscopic hematuria, and the inability to remove the catheter once introduced. Also, the in-hospital use of an indwelling urinary catheter in the elderly patient is associated with prolonged hospitalizations and an increased risk of in-hospital mortality. Although there are clinical criteria for the use of an indwelling urinary catheter, there is considerable variability in the utilization rates between hospitals and departments. For example, the rates of catheterization in general internal medicine departments usually varies between 8% to 20% and increases with the age of the patients. However, it has been shown that up to 50% of catheterizations are unjustified. Therefore, there are efforts to decrease the rate of use of urinary catheters on the one hand, and to limit the number of days with the indwelling catheter in place on the other hand. These efforts have been partially successful. The root of the problem is that the criteria for catheterization are generally vague, leading to variable interpretations. More precise definitions along with continuous monitoring will likely decrease catheterization rates without putting the patient at risk.
Evaluation of robotic endovascular catheters for arch vessel cannulation.
Riga, Celia V; Bicknell, Colin D; Hamady, Mohamad S; Cheshire, Nicholas J W
2011-09-01
Conventional catheter instability and embolization risk limits the adoption of endovascular therapy in patients with challenging arch anatomy. This study investigated whether arch vessel cannulation can be enhanced by a remotely steerable robotic catheter system. Seventeen clinicians with varying endovascular experience cannulated all arch vessels within two computed tomography-reconstructed pulsatile flow phantoms (bovine type I and type III aortic arches), under fluoroscopic guidance, using conventional and robotic techniques. Quantitative (catheterization times, catheter tip movements, vessel wall hits, catheter deflection) and qualitative metrics (Imperial College Complex Endovascular Cannulation Scoring Tool [IC3ST]) performance scores were compared. Robotic catheterization techniques resulted in a significant reduction in median carotid artery cannulation times and the median number of catheter tip movements for all vessels. Vessel wall contact with the aortic arch wall was reduced to a median of zero with robotic catheters. During stiff guidewire exchanges, robotic catheters maintained stability with zero deflection, independent of the distance the catheter was introduced into the carotid vessels. Overall IC3ST performance scores (interquartile range) were significantly improved using the robotic system: Type I arch score was 26/35 (20-30.8) vs 33/35 (31-34; P = .001), and type III arch score was 20.5/35 (16.5-28.5) vs 26.5/35 (23.5-28.8; P = .001). Low- and medium-volume interventionalists demonstrated an improvement in performance with robotic cannulation techniques. The high-volume intervention group did not show statistically significant improvement, but cannulation times, movements, and vessel wall hits were significantly reduced. Robotic technology has the potential to reduce the time, risk of embolization and catheter dislodgement, radiation exposure, and the manual skill required for carotid and arch vessel cannulation, while improving overall performance scores. Copyright © 2011 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Clarençon, Frédéric; Di Maria, Federico; Cormier, Evelyne; Gaudric, Julien; Sourour, Nader; Gabrieli, Joseph; Iosif, Christina; Jenny, Catherine; Koskas, Fabien; Chiras, Jacques
2013-11-01
The aim of this study was to compare the sensitivity of intra-aortic computed tomography angiography (IA-CTA) to that of regular spinal digital subtraction angiography for the presurgical location of the Adamkiewicz artery (AKA). Thirty patients (21 males, 9 females; mean age 64 years) had an IA-CTA for the location of the AKA before surgery of aneurysm (n = 24) or dissection (n = 6) of the thoracoabdominal aorta. After femoral artery puncture, a pigtail catheter was positioned at the origin of the descending aorta. CT acquisition was performed with an intra-aortic iodinated contrast media injection (15 mL/s, 120 mL). The visualization of the AKA and the location of the feeder(s) to the AKA were independently evaluated by two observers. Interrater agreement was calculated using a kappa test. Spinal angiogram by selective catheterization was systematically performed to confirm the results of the IA-CTA. The AKA was visualized by the IA-CTA in 27/30 cases (90 %); in 26/31 (84 %) cases, the continuity with the aorta was satisfactorily seen. Interrater agreement was good for the visualization of the AKA and its feeder(s): 0.625 and 0.87, respectively. In 75 % of the cases for which the AKA was visualized, the selective catheterization confirmed the results of the IA-CTA. In the remaining 25 % of the cases, the selective catheterization could not be performed due to marked vessels' tortuosity or ostium stenosis. IA-CTA is a feasible technique in a daily practice that presents a good sensitivity for the location of the AKA.
Dong, Guo-Chung; Chiu, Li-Chen; Ting, Chien-Kun; Hsu, Jia-Ruei; Huang, Chih-Chung; Chang, Yin; Chen, Gin-Shin
2017-09-01
Ultrasound guidance for epidural block has improved clinical blind-trial problems but the design of present ultrasonic probes poses operating difficulty of ultrasound-guided catheterization, increasing the failure rate. The purpose of this study was to develop a novel ultrasonic probe to avoid needle contact with vertebral bone during epidural catheterization. The probe has a central circular passage for needle insertion. Two focused annular transducers are deployed around the passage for on-axis guidance. A 17-gauge insulated Tuohy needle containing the self-developed fiber-optic-modified stylet was inserted into the back of the anesthetized pig, in the lumbar region under the guidance of our ultrasonic probe. The inner transducer of the probe detected the shallow echo signals of the peak-peak amplitude of 2.8 V over L3 at the depth of 2.4 cm, and the amplitude was decreased to 0.8 V directly over the L3 to L4 interspace. The outer transducer could detect the echoes from the deeper bone at the depth of 4.5 cm, which did not appear for the inner transducer. The operator tilted the probe slightly in left-right and cranial-caudal directions until the echoes at the depth of 4.5 cm disappeared, and the epidural needle was inserted through the central passage of the probe. The needle was advanced and stopped when the epidural space was identified by optical technique. The needle passed without bone contact. Designs of the hollow probe for needle pass and dual transducers with different focal lengths for detection of shallow and deep vertebrae may benefit operation, bone/nonbone identification, and cost.
Hagerty, Thomas; Kertesz, Louise; Schmidt, J Michael; Agarwal, Sachin; Claassen, Jan; Mayer, Stephan A; Larson, Elaine L; Shang, Jingjing
2015-02-01
Catheter-associated urinary tract infections (CAUTIs) are preventable adverse outcomes that cause increased morbidity, mortality, and financial burdens to hospitals. These are particularly prevalent in intensive care units (ICUs). Patients with subarachnoid hemorrhage (SAH) in neurological ICUs have extended lengths of stay and may be at higher risk for CAUTIs. The purpose of this study was to assess the prevalence of and risk factors for CAUTIs among patients with SAH in the neurological ICU of a large urban teaching hospital in the eastern United States. This is a retrospective analysis using the Columbia University SAH Outcomes Project data set collected between 2005 and 2012. Logistic regression is used to identify predictors of CAUTI. Catheterized adult patients (n = 242) with SAH over the 8-year period were included. The rate of CAUTIs was 20.7 per 1,000 catheter days, six times higher than the reported national average. Variables significantly associated with CAUTI were older age (odds ratio [OR] = 1.06, 95% confidence interval [CI] [1.01, 1.11]), blood sugar > 200 mg/dl (OR = 13.0, 95% CI [1.28, 107.4]), and anemia requiring transfusion (OR = 3.78, 95% CI [0.977, 14.67]). Higher CAUTI rates in this study were likely associated with prolonged catheterization. On the basis of these findings, careful assessment of the need for catheterization and increased vigilance regarding urinary catheter care in patients with SAH is indicated, particularly among those who are older, with anemia requiring transfusion and elevated blood glucose levels.
Tamura, Tetsuo; Nakamura, Hiroshi; Sato, Say; Seki, Makoto; Nishiki, Hideto
2014-06-01
This study proposed a modified procedure, using a small balloon catheter (SB catheter, 45 ml), for reducing bladder damage in cows. Holstein cows and the following catheters were prepared: smaller balloon catheter (XSB catheter; 30 ml), SB catheter and standard balloon catheter (NB catheter; 70 ml, as the commonly used, standard size). In experiment 1, each cow was catheterized. The occurrence of catheter-associated hematuria (greater than 50 RBC/HPF) was lower in the SB catheter group (0.0%, n=7) than in the NB catheter group (71.4%, n=7; P<0.05). In experiment 2, general veterinary parameters, urine pH, body temperature and blood values in cows were not affected before or after insertion of SB catheters (n=6). The incidence of urinary tract infection (UTI) was 3.0% per catheterized day (n=22). In experiment 3, feeding profiles, daily excretion of urinary nitrogen (P<0.05) and rate from nitrogen intake in urine (P<0.01), were higher with use of the SB catheter (n=13) than with the use of the vulva urine cup (n=18), indicating that using the SB catheter can provide accurate nutritional data. From this study, we concluded that when using an SB catheter, the following results occur; reduction in bladder damage without any veterinary risks and accuracy in regard to feeding parameters, suggesting this modified procedure using an SB catheter is a useful means of daily urine collection.
OnabotulinumtoxinA in overactive bladder: Evidence-based consensus recommendations.
Jiménez-Cidre, M A; Arlandis-Guzmán, S
2016-04-01
To offer a set of useful recommendations for urologists who are starting to provide treatment of overactive bladders with onabotulinumtoxinA. A literature search to December 2013 was conducted, as well as a subsequent critical reading of the selected publications. The coordinators prepared a document that was submitted for review by the members of the Spanish Group for the use of Botulinum Toxin in Urology. The expert group considered that onabotulinumtoxinA may be used for overactive bladder syndrome with urinary urge incontinence secondary to neurogenic or idiopathic detrusor overactivity for patients for whom conservative treatment and first-line medical treatment has failed, is not tolerated or is contraindicated. Treatment in most cases was performed with local intravesical anesthesia, although it can also be performed under epidural or general anesthesia. Patients must be informed of the possibility of requiring self-catheterization or temporary catheterization. Clinicians should ensure that the patients are capable of performing this catheterization before the treatment is conducted. Patients must also be informed of the need for antibiotic prophylaxis to reduce the risk of urinary tract infections. At least 2 follow-up visits are recommended: the first at days 7-14 after the injection and the second at 2-3 months. Reinjection is indicated when the effect of the treatment decreases. These guidelines can help clinicians in their daily decisions and limit the potential risks associated with the incorrect use of the drug. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.
TAMURA, Tetsuo; NAKAMURA, Hiroshi; SATO, Say; SEKI, Makoto; NISHIKI, Hideto
2014-01-01
ABSTRACT This study proposed a modified procedure, using a small balloon catheter (SB catheter, 45 ml), for reducing bladder damage in cows. Holstein cows and the following catheters were prepared: smaller balloon catheter (XSB catheter; 30 ml), SB catheter and standard balloon catheter (NB catheter; 70 ml, as the commonly used, standard size). In experiment 1, each cow was catheterized. The occurrence of catheter-associated hematuria (greater than 50 RBC/HPF) was lower in the SB catheter group (0.0%, n=7) than in the NB catheter group (71.4%, n=7; P<0.05). In experiment 2, general veterinary parameters, urine pH, body temperature and blood values in cows were not affected before or after insertion of SB catheters (n=6). The incidence of urinary tract infection (UTI) was 3.0% per catheterized day (n=22). In experiment 3, feeding profiles, daily excretion of urinary nitrogen (P<0.05) and rate from nitrogen intake in urine (P<0.01), were higher with use of the SB catheter (n=13) than with the use of the vulva urine cup (n=18), indicating that using the SB catheter can provide accurate nutritional data. From this study, we concluded that when using an SB catheter, the following results occur; reduction in bladder damage without any veterinary risks and accuracy in regard to feeding parameters, suggesting this modified procedure using an SB catheter is a useful means of daily urine collection. PMID:24561376
Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo
2015-01-01
OBJECTIVE: To evaluate the accuracy of diagnosing urinary tract infections using a new, recently described, standardized clean-catch collection technique. METHODS: Cross-sectional study of infants <90 days old admitted due to fever without a source, with two matched samples of urine obtained using two different methods: clean-catch standardized stimulation technique and bladder catheterization. RESULTS: Sixty paired urine cultures were obtained. The median age was 44-days-old. Seventeen percent were male infants. Clean-catch technique sensitivity was 97% (95% CI 82% to 100%) and specificity was 89% (95% CI 65% to 98%). The contamination rate of clean-catch samples was lower (5%) than the contamination rate of catheter specimens (8%). CONCLUSIONS: The sensitivity and specificity of urine cultures obtained using the clean-catch method through the new technique were accurate and the contamination rate was low. These results suggest that this technique is a valuable, alternative method for urinary tract infection diagnosis. PMID:26435675
Gibson, M A; Carell, E S
1997-11-01
The advent of transvenous right heart catheterization has relegated direct transthoracic right ventricular puncture largely to the role of "interesting historical footnote." However, in the case of a right ventricle that is "protected" by a mechanical tricuspid valve prosthesis, direct right ventricular puncture represents a reasonable alternative for obtaining accurate hemodynamic information.
Glaser, Alexander P; Rosoklija, Ilina; Johnson, Emilie K; Yerkes, Elizabeth B
2017-09-06
Current organizational guidelines regarding use of antibiotics during urinary tract catheterization are based on limited evidence and are not directly applicable to the pediatric urology population. We seek to improve understanding of this population by first evaluating current practices. This study aims to investigate practice patterns and attitudes of pediatric urologists regarding the use of antibiotics in the setting of urinary tract catheterization. An online survey was sent to members of the Society for Pediatric Urology. Questionnaire sections included demographics, general questions about antibiotic use with catheterization, and specific clinical scenarios. Descriptive statistics were used, and chi-square analysis was performed to examine associations between demographics and specific responses. Of 448 pediatric urologists surveyed, 154 (34%) responded to the survey. A majority of surveyed urologists (78%) prescribe daily prophylactic antibiotics with a hypospadias stent in place, but extensive variation in use of antibiotics was reported with other catheters and tubes. Extensive variation in practice patterns was also reported for three case scenarios regarding antibiotic prophylaxis with catheterization. Urologists > 50 years of age and fellowship-trained urologists were more likely to prescribe antibiotics for hypospadias stents (p = 0.02, p = 0.03), but no other significant associations between demographic characteristics and antibiotic use were found. There is substantial variation in practice patterns among surveyed pediatric urologists regarding prophylactic antibiotic use with urinary catheterization. This variation, combined with a lack of objective data and increasing pressure to decrease infectious complications and combat antibiotic resistance, highlights the need for development of management guidelines for this unique population.
Rios, Rodrigo; Loomba, Rohit S; Foerster, Susan R; Pelech, Andrew N; Gudausky, Todd M
2016-04-01
Coronary allograft vasculopathy (CAV) is the leading cause of graft failure in pediatric heart transplant recipients, also adding to mortality in this patient population. Coronary angiography is routinely performed to screen for CAV, with conventional single-plane or bi-plane angiography being utilized. Dual-axis rotational coronary angiography (RA) has been described, mostly in the adult population, and may offer reduction in radiation dose and contrast volume. Experience with this in the pediatric population is limited. This study describes a single-institution experience with RA for screening for CAV in pediatric patients. The catheterization database at our institution was used to identify pediatric heart transplant recipients having undergone RA to screen for CAV. Procedural data including radiation dose, fluoroscopy time, contrast volume, and procedure time were collected for each catheterization. The number of instances in which RA was not successful, ECG changes were present, and CAV was detected were also collected for each catheterization. A total of 97 patients underwent 345 catheterizations utilizing RA. Median radiation dose-area product per kilogram was found to be 341.7 (mGy cm(2)/kg), total air kerma was 126.8 (mGy), procedure time was 69 min, fluoroscopy time was 9.9 min, and contrast volume was 13 ml. A total of 17 (2 %) coronary artery injections out of 690 could not be successfully imaged using RA. A total of 14 patients had CAV noted at any point, 10 of whom had progressive CAV. Electrocardiographic changes were documented in a total of 10 (3 %) RA catheterizations. Procedural characteristics did not differ between serial catheterizations. RA is safe and feasible for CAV screening in pediatric heart transplant recipients while offering coronary imaging in multiple planes compared to conventional angiography.
Ripley, Lindsay; Christopoulos, Georgios; Michael, Tesfaldet T; Alomar, Mohammed; Rangan, Bavana V; Roesle, Michele; Kotsia, Anna; Banerjee, Subhash; Brilakis, Emmanouil S
2014-09-01
To determine the impact of music intervention on endothelial function, hemodynamics, and patient anxiety before, during, and after cardiac catheterization. The effect of music therapy during cardiac catheterization on endothelial function and patient satisfaction has received limited study. Seventy patients undergoing elective cardiac catheterization were randomized to music therapy (n=36) or no music therapy (n=34). Peripheral arterial tonometry was performed before and after catheterization. A 6 item (24-point scale) questionnaire evaluating patient anxiety and discomfort levels was also administered after the procedure. Both study groups had similar baseline characteristics, fluoroscopy time, and contrast administration. Reactive hyperemia index (RHI) change was 0.14 ± 0.72 in the music group and 0.30 ± 0.58 in the control group (P=.35). Systolic and diastolic blood pressure (BP) changes did not significantly differ between the two groups (systolic BP change -3.3 ± 17.3 mm Hg vs -2.3 ± 19.4 mm Hg; P=.83 and diastolic BP change -1.9 ± 12.2 mm Hg vs. 2.0 ± 13.4 mm Hg; P=.23). Heart rate changes were also comparable between the two groups (-1 ± 6 beats/ min vs -1 ± 7 beats/min; P=.22). Patient satisfaction questionnaire measurements were found to be similar in patients with and without music therapy (8 [7-11] vs 9 [8-12]; P=.36). In this study, music intervention did not elicit a vasodilator response, did not lower blood pressure or heart rate, and did not relieve anxiety or stress discomfort in patients who underwent coronary angiography.
Khera, Rohan; Pandey, Ambarish; Kumar, Nilay; Singh, Rajeev; Bano, Shah; Golwala, Harsh; Kumbhani, Dharam J; Girotra, Saket; Fonarow, Gregg C
2016-11-01
There has been an increase in the use of pulmonary artery (PA) catheters in heart failure (HF) in the United States in recent years. However, patterns of hospital use and trends in patient outcomes are not known. In the National Inpatient Sample 2001 to 2012, using International Classification of Diseases-Ninth Revision codes, we identified 11 888 525 adult (≥18 years) HF hospitalizations nationally, of which an estimated 75 209 (SE 0.6%) received a PA catheter. In 2001, the number of hospitals with ≥1 PA catheterization was 1753, decreasing to 1183 in 2011. The mean PA catheter use per hospital trended from 4.9 per year in 2001 (limits 1-133) to 3.8 per year in 2007 (limits 1-46), but increased to 5.5 per year in 2011 (limits 1-70). During 2001 to 2006, PA catheterization declined across hospitals; however, in 2007 to 2012, there was a disproportionate increase at hospitals with large bedsize, teaching programs, and advanced HF capabilities. The overall in-hospital mortality with PA catheter use was higher than without PA catheter use (13.1% versus 3.4%; P<0.0001); however, in propensity-matched analysis, differences in mortality between these groups have attenuated over time-risk-adjusted odds ratio for mortality for PA catheterization, 1.66 (95% confidence interval, 1.60-1.74) in 2001 to 2003 down to 1.04 (95% confidence interval, 0.97-1.12) in 2010 to 2012. There is substantial hospital-level variability in PA catheterization in HF along with increasing volume at fewer hospitals over-represented by large, academic hospitals with advanced HF capabilities. This is accompanied by a decline in excess mortality associated with PA catheterization. © 2016 American Heart Association, Inc.
Paz, Yehuda; Morgenstern, Rachelle; Weinberg, Richard; Chiles, Mariana; Bhatti, Navdeep; Ali, Ziad; Mohan, Sumit; Bokhari, Sabahat
2017-12-01
Cardiovascular disease is the leading cause of death in patients with end-stage renal disease (ESRD) and often goes undetected. Abnormal coronary flow reserve (CFR), which predicts increased risk of cardiac death, may be present in patients with ESRD without other evidence of coronary artery disease (CAD). We prospectively studied 131 patients who had rest and dipyridamole pharmacologic stress N 13 -ammonia positron emission tomography myocardial perfusion imaging (PET MPI) for kidney transplant evaluation. Thirty-four patients also had left heart catheterization. Abnormal PET MPI was defined as qualitative ischemia or infarct, stress electrocardiogram ischemia, or transient ischemic dilation. CFR was calculated as the ratio of stress to rest coronary blood flow. Global CFR < 2 was defined as abnormal. Of 131 patients who had PET MPI (66% male, 55.6 ± 12.1 years), 30% (39 of 131) had abnormal PET MPI and 59% (77 of 131) had abnormal CFR. In a subset of 34 patients who had left heart catheterization (66% male, 61.0 ± 12.1 years), 68% (23 of 34) had abnormal CFR on PET MPI, and 68% (23 of 34) had ≥70% obstruction on left heart catheterization. Abnormal CFR was not significantly associated with abnormal PET MPI (p = 0.13) or obstructive CAD on left heart catheterization (p = 0.26). In conclusion, in the first prospective study of PET MPI in patients with ESRD, abnormal CFR is highly prevalent and is independent of abnormal findings on PET MPI or obstructive CAD on left heart catheterization. Copyright © 2017 Elsevier Inc. All rights reserved.
Hollingsworth, John M; Rogers, Mary A M; Krein, Sarah L; Hickner, Andrew; Kuhn, Latoya; Cheng, Alex; Chang, Robert; Saint, Sanjay
2013-09-17
Although the epidemiology of catheter-associated urinary tract infection is well-described, little is known about noninfectious complications resulting from urethral catheter use. To determine the frequency of noninfectious complications after catheterization. MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, CINAHL, Conference Papers Index, BIOSIS Previews, Scopus, and ClinicalTrials.gov were searched for human studies without any language limits and through 30 July 2012. Clinical trials and observational studies assessing noninfectious complications of indwelling urethral catheters in adults. Relevant studies were sorted into 3 categories: short-term catheterization in patients without spinal cord injury (SCI), long-term catheterization in patients without SCI, and catheterization in patients with SCI. The proportion of patients who had bladder cancer, bladder stones, blockage, false passage, gross hematuria, accidental removal, urine leakage, or urethral stricture was then pooled using random-effects models. Thirty-seven studies (2868 patients) were pooled. Minor complications were common. For example, the pooled frequency of urine leakage ranged from 10.6% (95% CI, 2.4% to 17.7%) in short-term catheterization cohorts to 52.1% (CI, 28.6% to 69.5%) among outpatients with long-term indwelling catheters. Serious complications were also noted, including urethral strictures, which occurred in 3.4% (CI, 1.0% to 7.0%) of patients with short-term catheterization. For patients with SCI, 13.5% (CI, 3.4% to 21.9%) had gross hematuria and 1.0% (CI, 0.0% to 5.0%) developed bladder cancer. Although heterogeneity existed across studies for several outcomes, most could be accounted for by differences between studies with respect to quality and sex composition. Evidence published after 30 July 2012 is not included. Many noninfectious catheter-associated complications are at least as common as clinically significant urinary tract infections. Agency for Healthcare Research and Quality.
Lau, Kelvin C; Frank, David B; Hanna, Brian D; Patel, Akash R
2014-07-15
Electrocardiograms have utility in disease stratification and monitoring in adult pulmonary arterial hypertension (PAH). We examined the electrocardiographic findings that are common in pediatric PAH and assessed for correlation with disease severity and progression. We retrospectively identified patients aged≤18 years followed at a single institution from January 2001 to June 2012 with catheterization-confirmed diagnosis of idiopathic PAH and PAH secondary to pulmonary developmental abnormalities. Patients with an electrocardiography performed within 60 days of catheterization were included. Primary and secondary outcomes are the prevalence of abnormal electrocardiographic findings at the time of catheterization and the association between electrocardiographic and hemodynamic findings and electrocardiographic changes with disease progression on follow-up catheterization, respectively. Of the 100 electrocardiography-catheterization pairs derived from the 46 patients identified, 93% had an electrocardiographic abnormality: 78% had right ventricular hypertrophy (RVH) and 52% had right axis deviation (RAD) for age. In patients with idiopathic PAH, the presence of RVH and RAD correlated with pulmonary vascular resistance and transpulmonary gradient. RAD and RVH on baseline electrocardiogram was associated with an increased risk of disease progression on subsequent catheterization (odds ratio 11.0, 95% confidence interval 1.3 to 96.2, p=0.03) after adjusting for PAH subgroup. The sensitivity, specificity, and positive and negative predictive values of RAD and RVH on baseline electrocardiogram for disease progression were 92%, 48%, 33%, and 95%, respectively. In conclusion, electrocardiographic abnormalities are common in pediatric PAH. RAD and RVH on electrocardiogram were associated with worse hemodynamics, whereas their absence is suggestive of a lack of disease progression. Copyright © 2014 Elsevier Inc. All rights reserved.
Liang, Junkui; Jiang, Xiliang; Zhang, Xiulin; Cao, Wendong; Wang, Yong; Han, Jie
2015-11-01
The objective of this study was to investigate the effectiveness of interventional catheterization with staphylococcin aureus injection on ischemic necrosis of the femoral heads. By percutaneous catheterization of the femoral artery, papaverine, urokinase, compound Danshen, and anisodamine were injected intravenously into the arteries of the femoral head. Staphylococcin aureus injection was injected into the hit joint capsule on the side of the lesion to compare the conditions before and after surgery. The patients did the rehabilitation exercises of the hit joint 48 h after the surgery and had double crutches for 3-6 months. Of the 112 cases, 39 cases (34.8 %) were cured, 51 cases (45.6 %) were markedly effective, and 22 cases (19.6 %) were effective. Interventional catheterization combined with staphylococcin aureus injection given into the hit joint capsule is an effective way to treat ischemic necrosis of the femoral head by influencing the internal and external environments of the femoral head.
Shakuo, Tomoharu; Kakumoto, Shinichi; Kuribayashi, Junya; Oe, Katsunori; Seo, Katsuhiro
2017-01-01
It has been reported that PECS II block can alleviate postoperative pain following transapical transcatheter aortic valve implantation (TA-TAVI). However, the effectiveness of continuous PECS II block with catheterization has not yet been reported on the postoperative pain in patients undergoing TA-TAVI. We experienced two cases of TA-TAVI who received PECS II block with catheterization to manage postoperative pain. In the first case, a bolus injection for intraoperative pain and subsequent catheterization were performed before the implantation. However, the patient developed severe pain postoperatively in spite of the continuous block due to displacement of the catheter. In the second case, a bolus injection and the catheterization for the continuous block were performed before and after the implantation, respectively, which provided high-quality pain control. Continuous PECS II block may be useful to control perioperative pain associated with TA-TAVI. The insertion of the catheter after the implantation could be useful to avoid its displacement during the surgery.
Aydın, Kutlay; Tokur, Murat Emre; Ergan, Begüm
2018-01-01
A persistent left-sided superior vena cava (PLSVC) is the most frequent abnormality of the venous system; however, it is not a very well-known variation among physicians. Herein we report the case of a patient with a PLSVC who was diagnosed after central venous catheterization (CVC). An 80-year-old man was admitted to the emergency room with cardiopulmonary arrest. After the return of spontaneous circulation, CVC was blindly performed from the left jugular vein without any complications. However, routine chest X-ray after catheterization revealed that the catheter was moving down directly to the left heart. Thoracic computed tomography showed the right brachiocephalic vein draining into the left brachiocephalic vein and forming the left superior vena cava in front of the aortic arch. The left superior vena cava merged into the right atrium after crossing the left pulmonary artery. CVC is widely used in clinical practice, and therefore clinicians should be aware of possible variations in central veins, particularly during blind catheterization.
Rafii-Tari, Hedyeh; Liu, Jindong; Payne, Christopher J; Bicknell, Colin; Yang, Guang-Zhong
2014-01-01
Despite increased use of remote-controlled steerable catheter navigation systems for endovascular intervention, most current designs are based on master configurations which tend to alter natural operator tool interactions. This introduces problems to both ergonomics and shared human-robot control. This paper proposes a novel cooperative robotic catheterization system based on learning-from-demonstration. By encoding the higher-level structure of a catheterization task as a sequence of primitive motions, we demonstrate how to achieve prospective learning for complex tasks whilst incorporating subject-specific variations. A hierarchical Hidden Markov Model is used to model each movement primitive as well as their sequential relationship. This model is applied to generation of motion sequences, recognition of operator input, and prediction of future movements for the robot. The framework is validated by comparing catheter tip motions against the manual approach, showing significant improvements in the quality of catheterization. The results motivate the design of collaborative robotic systems that are intuitive to use, while reducing the cognitive workload of the operator.
Pilz, Guenter; Patel, Pankaj A; Fell, Ulrich; Ladapo, Joseph A; Rizzo, John A; Fang, Hai; Gunnarsson, Candace; Heer, Tobias; Hoefling, Berthold
2011-01-01
The health and economic implications of new imaging technologies are increasingly relevant policy issues. Cardiac magnetic resonance imaging (CMR) is currently not or not sufficiently reimbursed in a number of countries including Germany, presumably because of a limited evidence base. It is unknown, however, whether it can be effectively used to facilitate medical decision-making and reduce costs by serving as a gatekeeper to invasive coronary angiography. We investigated whether the application of CMR in patients suspected of having coronary artery disease (CAD) reduces costs by averting referrals to cardiac catheterization. We used propensity score methods to match 218 patients from a CMR registry to a previously studied cohort in which CMR was demonstrated to reliably identify patients who were low-risk for major cardiac events. Covariates over which patients were matched included comorbidity profiles, demographics, CAD-related symptoms, and CAD risk as measured by Morise scores. We determined the proportion of patients for whom cardiac catheterization was deferred based upon CMR findings. We then calculated the economic effects of practice pattern changes using data on cardiac catheterization and CMR costs. CMR reduced the utilization of cardiac catheterization by 62.4%. Based on estimated catheterization costs of € 619, the utilization of CMR as a gatekeeper reduced per-patient costs by a mean of € 90. Savings were realized until CMR costs exceeded € 386. Cost savings were greatest for patients at low-risk for CAD, as measured by baseline Morise scores, but were present for all Morise subgroups with the exception of patients at the highest risk of CAD. CMR significantly reduces the utilization of cardiac catheterization in patients suspected of having CAD. Per-patient savings range from € 323 in patients at lowest risk of CAD to € 58 in patients at high-risk but not in the highest risk stratum. Because a negative CMR evaluation has high negative predictive value, its application as a gatekeeper to cardiac catheterization should be further explored as a treatment option.
Patel, Pankaj A.; Fell, Ulrich; Ladapo, Joseph A.; Rizzo, John A.; Fang, Hai; Gunnarsson, Candace; Heer, Tobias; Hoefling, Berthold
2010-01-01
The health and economic implications of new imaging technologies are increasingly relevant policy issues. Cardiac magnetic resonance imaging (CMR) is currently not or not sufficiently reimbursed in a number of countries including Germany, presumably because of a limited evidence base. It is unknown, however, whether it can be effectively used to facilitate medical decision-making and reduce costs by serving as a gatekeeper to invasive coronary angiography. We investigated whether the application of CMR in patients suspected of having coronary artery disease (CAD) reduces costs by averting referrals to cardiac catheterization. We used propensity score methods to match 218 patients from a CMR registry to a previously studied cohort in which CMR was demonstrated to reliably identify patients who were low-risk for major cardiac events. Covariates over which patients were matched included comorbidity profiles, demographics, CAD-related symptoms, and CAD risk as measured by Morise scores. We determined the proportion of patients for whom cardiac catheterization was deferred based upon CMR findings. We then calculated the economic effects of practice pattern changes using data on cardiac catheterization and CMR costs. CMR reduced the utilization of cardiac catheterization by 62.4%. Based on estimated catheterization costs of € 619, the utilization of CMR as a gatekeeper reduced per-patient costs by a mean of € 90. Savings were realized until CMR costs exceeded € 386. Cost savings were greatest for patients at low-risk for CAD, as measured by baseline Morise scores, but were present for all Morise subgroups with the exception of patients at the highest risk of CAD. CMR significantly reduces the utilization of cardiac catheterization in patients suspected of having CAD. Per-patient savings range from € 323 in patients at lowest risk of CAD to € 58 in patients at high-risk but not in the highest risk stratum. Because a negative CMR evaluation has high negative predictive value, its application as a gatekeeper to cardiac catheterization should be further explored as a treatment option. PMID:20524070
Suggs, Patricia M; Lewis, Rebecca; Hart, Ann C; Troutman-Jordan, Meredith; Hardin, Sonya R
Patients frequently complain of back pain after cardiac catheterization, and there is a lack of evidence to guide practice regarding patient comfort while maintaining hemostasis at femoral access site after cardiac catheterization. The aim of this study was to examine if frequent position changes affect a patient's pain level or increase incidents of bleeding in the recovery period after cardiac catheterization. A quasi-experimental pretest/posttest design was used to evaluate a patient's reported pain levels and positioning changes during bed rest period postprocedure. Twenty charts were reviewed to note documentation of patient position, self-reported pain rating related to pain relief goals, and occurrence of bleeding at the procedure site. A survey was conducted to reveal nurse attitudes, knowledge, and beliefs regarding positioning and pain management for patients in the post-cardiac catheterization period. Results from this survey were used to develop education and data collection tools. Education regarding perceived barriers and importance of maximizing activity orders for patient comfort was provided to nursing staff. After nurse education, an additional 20 charts were reviewed to note if increasing frequency of position change affects pain levels reported by patients or if any increased incidence of bleeding was noted with greater frequency of position change. Data were analyzed using correlation analyses. Greater levels of pain were associated with higher pain ratings (r = 0.796, P < .000). Use of position change only as a comfort measure was negatively associated with pain ratings; in other words, lower patient pain ratings were associated with use of positioning only without addition of medications to address complaint (r = -0.493, P < .023). There was a significant increase in number of pain management goals met from before to after education intervention (P < .046). Nurse concern for increased bleeding was found to be the most common barrier for use of position changes for comfort after cardiac catheterization. This initial analysis suggests position changes in conjunction with pain medication are beneficial in managing pain after cardiac catheterization. There was no increase in bleeding or complications reported; however this study had a small sample size, and caution should be used regarding generalization of findings.
Tavichakorntrakool, Ratree; Prasongwattana, Vitoon; Sungkeeree, Seksit; Saisud, Phitsamai; Sribenjalux, Pipat; Pimratana, Chaowat; Bovornpadungkitti, Sombat; Sriboonlue, Pote; Thongboonkerd, Visith
2012-11-01
Urinary tract infections are generally known to be associated with nephrolithiasis, particularly struvite stone, in which the most common microbe found is urea-splitting bacterium, i.e. Proteus mirabilis. However, our observation indicated that it might not be the case of stone formers in Thailand. We therefore extensively characterized microorganisms associated with all types of kidney stones. A total of 100 kidney stone formers (59 males and 41 females) admitted for elective percutaneous nephrolithotomy were recruited and microorganisms isolated from catheterized urine and cortex and nidus of their stones were analyzed. From 100 stone formers recruited, 36 cases had a total of 45 bacterial isolates cultivated from their catheterized urine and/or stone matrices. Among these 36 cases, chemical analysis by Fourier-transformed infrared spectroscopy revealed that 8 had the previously classified 'infection-induced stones', whereas the other 28 cases had the previously classified 'metabolic stones'. Calcium oxalate (in either pure or mixed form) was the most common and found in 64 and 75% of the stone formers with and without bacterial isolates, respectively. Escherichia coli was the most common bacterium (approximately one-third of all bacterial isolates) found in urine and stone matrices (both nidus and periphery). Linear regression analysis showed significant correlation (r = 0.860, P < 0.001) between bacterial types in urine and stone matrices. Multidrug resistance was frequently found in these isolated bacteria. Moreover, urea test revealed that only 31% were urea-splitting bacteria, whereas the majority (69%) had negative urea test. Our data indicate that microorganisms are associated with almost all chemical types of kidney stones and urea-splitting bacteria are not the major causative microorganisms found in urine and stone matrices of the stone formers in Thailand. These data may lead to rethinking and a new roadmap for future research regarding the role of microorganisms in kidney stone formation.
Ribot, C; Dutau, G; Manelfe, C; Bouissou, H; Rochiccioli, P
1977-02-01
A parathyroid adenoma is reported in a girl aged 12 years in whom hypercalcaemia was discovered by chance. Investigation of calcium metabolism suggested the diagnosis of hyperparathyroidism and studies of the urinary cyclic AMP and determination of the plasma parathyroid hormone concentration further added to the evidence. The diagnosis of parathyroid adenoma was made after determination of the parathyroid hormone concentration at various sights during selective catheterization of the tyroid veins. This was confirmed at surgery. In this patient the place of catheterization of the inferior thyroid veins in the early diagnosis of primary hyperparathyroidism is discussed.
Ekinci, Saniye; Çiftçi, Arbay Özden; Karnak, İbrahim; Şenocak, Mehmet Emin
2016-04-01
Hypospadias is a common congenital anomaly. Over 300 techniques have been described for repairing hypospadias. Eccentric circummeatal based flap with combined limited urethral mobilization technique (ECMB-LUM) is a simple procedure to repair distal hypospadias with minimal complication rate. This study presents results of this technique, highlighting surgical pitfalls to achieve the best result. Medical records of patients with distal hypospadias operated on using the same technique between 1998 and 2011 were reviewed retrospectively. Age at surgery, position of meatus preoperatively and postoperatively, duration of urethral catheterization and hospitalization, early and late complications, previous hypospadias repairs, and secondary surgical interventions were evaluated. In the surgical technique an eccentric circummeatal based flap is outlined. The proximal part of the flap is dissected from the underlying urethra and Buck's fascia. If the flap is not long enough, the distal urethra is mobilized a few millimeters (Figure). The eccentric flap is sutured to the tip of the glans. The glans wings are approximated in the midline. A urethral catheter of 6 Fr or 8 Fr is passed and left in the bulbous urethra or the urinary bladder. Diverged limbs of corpus spongiosum are approximated on the urethra, then, the glans and skin of the penile shaft are sutured. Of the 171 consecutive patients operated on using the ECMB-LUM technique; 115 had coronal, 47 had subcoronal, and nine had glanular meatus. The mean age at surgery was 4.5 (1-17) years. Patients were hospitalized for 2.2 ± 0.7 days. Mean duration of urethral catheterization was 2.3 ± 0.5 days. All but eight patients had ECBF-LUM as primary repair. There were no early complications such as bleeding, hematoma, and wound infection. All patients voided spontaneously after catheter removal. Late complications were meatal stenosis, urethrocutaneous fistula, meatal regression, and glandular dehiscence (Table). These patients were treated using dilatation, fistula repair, meatoplasty, and secondary repair with the same technique, respectively. Eventually all patients had a vertical slit-like meatus on the tip of a natural looking glans. The most commonly used distal hypospadias repair techniques are glanular approximation, meatal advancement and glanuloplasty, Koff, Mathieu, Thiersch-Duplay procedure, tubularized incised plate repairs, and modifications of these techniques. Cosmetic and functional results and complication rates of ECMB-LUM technique are comparable with those of the commonly used techniques. Copyright © 2015 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Gregory, P M; Rhoads, G G; Wilson, A C; O'Dowd, K J; Kostis, J B
1999-09-01
Reports indicate that black patients are less likely than white patients to receive invasive cardiac services after hospitalization for acute myocardial infarction (AMI). There is still uncertainty as to why racial differences exist and how they affect patient outcomes. This is the first study to focus on the availability of invasive cardiac services and racial differences in procedure use. Study objectives were to (1) document whether racial differences existed in the use of invasive cardiac procedures, (2) study whether these racial differences were related to availability of hospital-based invasive cardiac services at first admission for AMI, and (3) determine whether there were racial differences in long-term mortality rates. A historical cohort study was conducted with discharge records from all acute care hospitals in New Jersey for 1993 linked to death certificate records for 1993 and 1994. There were 13,690 black and white New Jersey residents hospitalized with primary diagnosis of AMI. Use of cardiac catheterization within 90 days, revascularization within 90 days (percutaneous transluminal coronary angioplasty [PTCA] or coronary artery bypass graft surgery [CABG]), and death within 1 year after admission for AMI were the main outcome measures. Patterns for PTCA and CABG as separate outcomes were also studied. Hospital-based cardiac services available were described as no invasive cardiac services, catheterization only, or PTCA/CABG. To account for payer status and comorbidity differences, patients 65 years and older with Medicare coverage were analyzed separately from those younger than 65 years. Black patients aged 65 and older were generally less likely to receive catheterization and revascularization than white patients, regardless of facilities available at first admission. For patients younger than 65 years, the greatest differences between black and white patients in catheterization and PTCA/CABG use within 90 days after AMI occurred when no hospital-based invasive cardiac services were available. However, use of invasive cardiac procedures within 90 days after AMI was substantially increased if the first hospital offered catheterization only or PTCA/CABG services, among all patients, especially among blacks younger than age 65. No significant racial differences or interactions with available services were found in 1-year mortality rates. Availability of invasive cardiac services at first hospitalization for AMI was associated with increased procedure use for both races. However, use of invasive cardiac procedures was generally lower for black patients than for white patients, regardless of services available. Long-term mortality rates after hospitalization for AMI did not differ between blacks and whites.
21 CFR 870.1310 - Vessel dilator for percutaneous catheterization.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vessel dilator for percutaneous catheterization. 870.1310 Section 870.1310 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1310...
21 CFR 870.1310 - Vessel dilator for percutaneous catheterization.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vessel dilator for percutaneous catheterization. 870.1310 Section 870.1310 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1310...
Rubin, S J; Lyons, R W; Murcia, A J
1978-01-01
A gram-positive coccus, presently named Micrococcus mucilaginosus incertae sedis, was isolated from 14 blood cultures from a patient with endocarditis. The first positive blood culture was drawn 5 days after the patient underwent cardiac catheterization. PMID:670378
André Cournand, Bellevue's Cardiopulmonary Laboratory, and Research on Heart Failure.
Braunwald, Eugene
2018-02-01
In 1954-1955, the author served as a research fellow in the cardiopulmonary laboratory led by André Cournand at Bellevue Hospital in New York. Cournand was a pulmonary physiologist and a professor of medicine at Columbia University. In his quest to obtain mixed venous blood to calculate pulmonary blood flow, he catheterized the right atrium, right ventricle, and pulmonary artery in patients and also measured the pressures in these chambers. Cournand and his collaborators soon appreciated the enormous potential of cardiac catheterization in deepening the understanding of cardiovascular pathophysiology. After a series of groundbreaking studies, Cournand and his coworker Dickinson Richards, as well as German physician Werner Forssmann, were awarded a Nobel Prize in 1956. Cournand's laboratory, his work habits, and his rigorous approach to science are described, as well as the stimulation the author received during the author's fellowship. As a result, the author went on to extend to the left side of the heart the observations that the Cournand group had conducted in the right heart. Also, the author continued Cournand's work on heart failure by developing techniques to measure ventricular function in patients and to describe the neurohumoral changes that occur in human heart failure.
[Selective embolization to treat obstetric hemorrhage].
Ferrer Puchol, M D; Lanciego, C; Esteban, E; Ciampi, J J; Edo, M A; Ferragud, S
2014-01-01
To describe cases of obstetric hemorrhage that have called for selective intra-arterial embolization and the different embolization techniques used. To assess the clinical outcomes and postprocedural fertility. We studied 27 women with obstetric hemorrhage. In 24 patients, embolization was performed by catheterizing both uterine arteries and in 2 patients only one uterine artery was catheterized (pseudoaneurysm). The materials used for embolization consisted of Spongostan in 17/27, particles in 9/27, and coils in 1/27. Clinical follow-up included an analysis of early and late complications and of postprocedural fertility. Hemorrhage was classified as primary (25/27) or secondary (2/27). The cause of bleeding was vaginal delivery (20), cesarean sections (5), abortion (1), and cervical ectopic pregnancy (1). The initial technical success rate was 100% and the clinical success rate was 92.6% (25 of the 27 patients). Bleeding ceased and the outcome was satisfactory in 25 patients. During clinical follow-up ranging from one to seven years, 23 patients had normal menstruation and 6 patients completed 7 full-term pregnancies. Intra-arterial embolization for obstetric hemorrhage leads to good outcomes and few complications and it preserves fertility. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.
Personal Computer System for Automatic Coronary Venous Flow Measurement
Dew, Robert B.
1985-01-01
We developed an automated system based on an IBM PC/XT Personal computer to measure coronary venous blood flow during cardiac catheterization. Flow is determined by a thermodilution technique in which a cold saline solution is infused through a catheter into the coronary venous system. Regional temperature fluctuations sensed by the catheter are used to determine great cardiac vein and coronary sinus blood flow. The computer system replaces manual methods of acquiring and analyzing temperature data related to flow measurement, thereby increasing the speed and accuracy with which repetitive flow determinations can be made.
Vaginal gamete intrafallopian transfer. Experience with 14 cases.
Lucena, E; Paulson, J D; Ruiz, J; Asmar, P; Mendoza, J C; Ortiz, J A; Gomez, M; Arango, A; Lucena, C; Lucena, A
1990-06-01
A procedure utilizing transvaginal aspiration of stimulated gametes followed by transcervical, ultrasound-guided catheterization of the tubal ostia was performed as a modification of the standardized gamete intrafallopian transfer (GIFT) technique. Among 14 patients with 16 cycles there were four normal, intrauterine pregnancies and one ectopic pregnancy. In two patients the beta-human gonadotropin level rose significantly and then started to fall; the patients aborted spontaneously. The procedure can be performed with a higher degree of patient acceptance than can traditional GIFT, and the success rate in this small series was promising.
[Current radionuclear methods in the diagnosis of regional myocardial circulation disorders].
Felix, R; Winkler, C
1977-01-29
Among nuclear medical diagnostic procedures a distinction can be made between non-invasive and invasive methods. The non-invasive methods serve either to image the still viable myocardium ("cold spot" technique) or for direct visualization of recently infarcted myocardial tissue ("hot spot" technique). These methods have the advantage of simple handling and good reproducibility. Side effects and risks are thus far unknown. Improvement of local dissolution should be aimed at in the future and wound greatly increase diagnostic and topographic security. The invasive procedures always require catheterization of the coronary arteries. This is the reason why they can be performed only with coronary arteriography. The Xenon "wash out" technique permits, with some restrictions, quantitative measurement of the regional flow rate. The "inflow technique" permits determination of perfusion distribution. The possibilities of the "double-radionuclide" scintigramm are discussed. For measurement of activity distribution, sationary detectors are generally preferred. In the case of the time-activity curves with the Xenon "wash out" technique, single detectors offer certain advantages.
Asymptomatic bacteriuria. Clinical significance and management.
Raz, Raul
2003-10-01
The clinical significance and management of asymptomatic bacteriuria (ASB) differs according to different groups of patients. ASB requires antibiotic treatment in pregnant women, children aged 5-6 years and prior to invasive genitourinary procedures. However, there is a consensus that ASB in the elderly, healthy school girls and young women, diabetic women and patients with indwelling catheters or intermittent catheterization has no clinical significance and antibiotic prescription is not indicated.
Rocha, Leonardo Lima; Pessoa, Camila Menezes Souza; Neto, Ary Serpa; do Prado, Rogerio Ruscitto; Silva, Eliezer; de Almeida, Marcio Dias; Correa, Thiago Domingos
2017-02-27
Liver failure patients have traditionally been empirically transfused prior to invasive procedures. Blood transfusion is associated with immunologic and nonimmunologic reactions, increased risk of adverse outcomes and high costs. Scientific evidence supporting empirical transfusion is lacking, and the best approach for blood transfusion prior to invasive procedures in cirrhotic patients has not been established so far. The aim of this study is to compare three transfusion strategies (routine coagulation test-guided - ordinary or restrictive, or thromboelastometry-guided) prior to central venous catheterization in critically ill patients with cirrhosis. Design and setting: a double-blinded, parallel-group, single-center, randomized controlled clinical trial in a tertiary private hospital in São Paulo, Brazil. adults (aged 18 years or older) admitted to the intensive care unit with cirrhosis and an indication for central venous line insertion. Patients will be randomly assigned to three groups for blood transfusion strategy prior to central venous catheterization: standard coagulation tests-based, thromboelastometry-based, or restrictive. The primary efficacy endpoint will be the proportion of patients transfused with any blood product prior to central venous catheterization. The primary safety endpoint will be the incidence of major bleeding. Secondary endpoints will be the proportion of transfusion of fresh frozen plasma, platelets and cryoprecipitate; infused volume of blood products; hemoglobin and hematocrit before and after the procedure; intensive care unit and hospital length of stay; 28-day and hospital mortality; incidence of minor bleeding; transfusion-related adverse reactions; and cost analysis. This study will evaluate three strategies to guide blood transfusion prior to central venous line placement in severely ill patients with cirrhosis. We hypothesized that thromboelastometry-based and/or restrictive protocols are safe and would significantly reduce transfusion of blood products in this population, leading to a reduction in costs and transfusion-related adverse reactions. In this manner, this trial will add evidence in favor of reducing empirical transfusion in severely ill patients with coagulopathy. ClinicalTrials.gov, identifier: NCT02311985 . Retrospectively registered on 3 December 2014.
Sahin, Sabiha; Donmez, Dilek Burukoglu
2018-01-01
Background Acute kidney injury (AKI) secondary to sepsis is a major cause of morbidity and mortality in the human intensive care unit (ICU). Kidney function and the histological findings of AKI were investigated in an experimental rat model with sepsis induced by cecal ligation and puncture (CLP) and compared with and without treatment with carnosine (beta-alanyl-L-histidine). Material/Methods Twenty-four Sprague-Dawley rats were randomly divided into three groups consisting eight rats in each: Group 1 – control; Group 2 – septic shock; and Group 3 – septic shock treated with carnosine. Femoral vein and artery catheterization were applied in all rats. Rats in Group 1 underwent laparotomy and catheterization. The other two groups with septic shock underwent laparotomy, CLP, catheterization, and bladder cannulation. Rats in Group 3 received an intraperitoneal (IP) injection of 250 mg/kg carnosine, 60 min following CLP. Rats were monitored for blood pressure, pulse rate, and body temperature to assess responses to postoperative sepsis, and 10 mL/kg saline replacement was administered. Twenty-four hours following CLP, rats were sacrificed, and blood and renal tissue samples were collected. Results Statistically significant improvements were observed in kidney function, tissue and serum malondialdehyde levels, routine blood values, biochemical indices, and in histopathological findings in rats in Group 3 who were treated with carnosine, compared with Group 2 exposed to septic shock without carnosine treatment. Conclusions Carnosine (beta-alanyl-L-histidine) has been shown to have beneficial effects in reducing AKI due to septic shock in a rat model of septicemia. PMID:29334583
Bei, Wei-Jie; Wang, Kun; Li, Hua-Long; Lin, Kai-Yang; Guo, Xiao-Sheng; Chen, Shi-Qun; Liu, Yong; Yi, Shi-Xin; Luo, De-Mou; Chen, Ji-Yan; Tan, Ning
2017-09-01
Few studies have investigated the efficacy and safety of hydration to prevent contrast-induced acute kidney injury (CI-AKI) and worsening heart failure (WHF) after cardiac catheterization in heart failure and preserved ejection fraction (HFpEF; HF and EF ≥50%) patients. We recruited 1206 patients with HFpEF undergoing cardiac catheterization with periprocedural hydration volume/weight (HV/W) ratio data and investigated the relationship between hydration volumes and risk of CI-AKI and WHF. Incidence of CI-AKI was not significantly reduced in individuals with higher HV/W [quartile (Q) 1, Q2, Q3, and Q4: 9.7%, 10.2%, 12.7%, and 12.2%, respectively; P = 0.219]. Multivariate analysis indicated that higher HV/W ratios were not associated with decreased CI-AKI risks [Q2 vs. Q1: odds ratio (OR), 0.95; Q3 vs. Q1: OR, 1.07; Q4 vs. Q1: OR, 0.92; all P > 0.05]. According to multivariate analysis, higher HV/W significantly increased the WHF risk (Q4 vs. Q1: adjusted OR, 8.13 and 95% confidence interval, 1.03-64.02; P = 0.047). CI-AKI and WHF were associated with a significantly increased risk of long-term mortality (mean follow-up, 2.33 years). For HFpEF patients, an excessively high hydration volume might not be associated with lower risk of CI-AKI but may increase the risk of postprocedure WHF.
Clean Intermittent Catheterization in the School Setting
ERIC Educational Resources Information Center
Katrancha, Elizabeth D.
2008-01-01
Spina bifida (SB) is a neural tube defect that causes many physical and mental disabilities. Bowel and bladder incontinence is the disability seen most often in these students that requires the school nurse's attention. Clean intermittent catheterization (CIC) provides the student with SB a vehicle to reach a satisfactory level of continence,…
Kubota, Hiroshi; Nomura, Tetsuya; Hori, Yusuke; Yoshioka, Kenichi; Miyawaki, Daisuke; Urata, Ryota; Sugimoto, Takeshi; Kikai, Masakazu; Keira, Natsuya; Tatsumi, Tetsuya
2017-06-01
Catheter-induced coronary dissection involving left main bifurcation is a rare complication during cardiac catheterization but can become lethal unless it is treated appropriately. Interventional cardiologists always have to pay attention to the risk of complications related to cardiac catheterization and prepare for determining the best bailout strategy for the situation.
Proteus mirabilis biofilm - qualitative and quantitative colorimetric methods-based evaluation.
Kwiecinska-Piróg, Joanna; Bogiel, Tomasz; Skowron, Krzysztof; Wieckowska, Ewa; Gospodarek, Eugenia
2014-01-01
Proteus mirabilis strains ability to form biofilm is a current topic of a number of research worldwide. In this study the biofilm formation of P. mirabilis strains derived from urine of the catheterized and non-catheterized patients has been investigated. A total number of 39 P. mirabilis strains isolated from the urine samples of the patients of dr Antoni Jurasz University Hospital No. 1 in Bydgoszcz clinics between 2011 and 2012 was used. Biofilm formation was evaluated using two independent quantitative and qualitative methods with TTC (2,3,5-triphenyl-tetrazolium chloride) and CV (crystal violet) application. The obtained results confirmed biofilm formation by all the examined strains, except quantitative method with TTC, in which 7.7% of the strains did not have this ability. It was shown that P. mirabilis rods have the ability to form biofilm on the surfaces of both biomaterials applied, polystyrene and polyvinyl chloride (Nelaton catheters). The differences in ability to form biofilm observed between P. mirabilis strains derived from the urine of the catheterized and non-catheterized patients were not statistically significant.
Calvi, Laura; Daniels, Gilbert H
2011-04-01
Thyrotoxicosis caused by destructive thyroiditis is self-limited and results from the subacute release of preformed thyroid hormone. Common etiologies include painful subacute thyroiditis and silent (painless) subacute thyroiditis (including postpartum thyroiditis, amiodarone-associated destructive thyroiditis, and lithium-associated thyroiditis). Thyrotoxicosis commonly evolves slowly over a matter of weeks. We report a unique case of severe thyrotoxicosis caused by acute- onset painful destructive thyroiditis in a patient who received large amounts of nonionic contrast dye Hexabrix® for cardiac catheterization. The results of thyroid function and physical examination were normal before the catheterization. The acute onset of severe thyroid pain, rapid increase in serum Free Thyroxine Index, and thyroglobulin concentrations with a triiodothyronine to free thyroxine index ratio of < 20 to 1 were compatible with an acute onset destructive thyroiditis, likely related to direct toxicity from the iodinated contrast material. In light of the large number of patients who receive these contrast agents during cardiac catheterization, clinicians should be advised of this potentially serious complication, particularly in the setting of unstable cardiac disease.
Ghetti, Claire M
2013-01-01
Individuals undergoing cardiac catheterization are likely to experience elevated anxiety periprocedurally, with highest anxiety levels occurring immediately prior to the procedure. Elevated anxiety has the potential to negatively impact these individuals psychologically and physiologically in ways that may influence the subsequent procedure. This study evaluated the use of music therapy, with a specific emphasis on emotional-approach coping, immediately prior to cardiac catheterization to impact periprocedural outcomes. The randomized, pretest/posttest control group design consisted of two experimental groups--the Music Therapy with Emotional-Approach Coping group [MT/EAC] (n = 13), and a talk-based Emotional-Approach Coping group (n = 14), compared with a standard care Control group (n = 10). MT/EAC led to improved positive affective states in adults awaiting elective cardiac catheterization, whereas a talk-based emphasis on emotional-approach coping or standard care did not. All groups demonstrated a significant overall decrease in negative affect. The MT/EAC group demonstrated a statistically significant, but not clinically significant, increase in systolic blood pressure most likely due to active engagement in music making. The MT/EAC group trended toward shortest procedure length and least amount of anxiolytic required during the procedure, while the EAC group trended toward least amount of analgesic required during the procedure, but these differences were not statistically significant. Actively engaging in a session of music therapy with an emphasis on emotional-approach coping can improve the well-being of adults awaiting cardiac catheterization procedures.
Achieving femoral artery hemostasis after cardiac catheterization: a comparison of methods.
Schickel, S I; Adkisson, P; Miracle, V; Cronin, S N
1999-11-01
Cardiac catheterization is a common procedure that involves the introduction of a small sheath (5F-8F) into the femoral artery for insertion of other diagnostic catheters. After cardiac catheterization, local compression of the femoral artery is required to prevent bleeding and to achieve hemostasis. Traditional methods of achieving hemostasis require significant time and close supervision by medical personnel and can contribute to patients' discomfort. VasoSeal is a recently developed device that delivers absorbable collagen into the supra-arterial space to promote hemostasis. To compare outcomes between patients receiving a collagen plug and patients in whom a traditional method of achieving hemostasis was used after diagnostic cardiac catheterization. An outcomes tracking tool was used to analyze the medical records of 95 patients in whom a traditional method was used (traditional group) and 81 patients in whom VasoSeal was used (device group) to achieve hemostasis. Complications at the femoral access site, patients' satisfaction, and times to hemostasis, ambulation, and discharge were compared. Hematomas of 6-cm diameter occurred in 5.3% of the traditional group; no complications occurred in the device group. The device group also achieved hemostasis faster and had earlier ambulation (P < .001). Patients in the device group were discharged a mean of 5 hours sooner than patients in the traditional group (P < .05). No significant differences were found in patients' satisfaction. VasoSeal is a safe and effective method of achieving hemostasis after cardiac catheterization that can hasten time to hemostasis, ambulation, and discharge.
Direct measurement of a patient's entrance skin dose during pediatric cardiac catheterization
Sun, Lue; Mizuno, Yusuke; Iwamoto, Mari; Goto, Takahisa; Koguchi, Yasuhiro; Miyamoto, Yuka; Tsuboi, Koji; Chida, Koichi; Moritake, Takashi
2014-01-01
Children with complex congenital heart diseases often require repeated cardiac catheterization; however, children are more radiosensitive than adults. Therefore, radiation-induced carcinogenesis is an important consideration for children who undergo those procedures. We measured entrance skin doses (ESDs) using radio-photoluminescence dosimeter (RPLD) chips during cardiac catheterization for 15 pediatric patients (median age, 1.92 years; males, n = 9; females, n = 6) with cardiac diseases. Four RPLD chips were placed on the patient's posterior and right side of the chest. Correlations between maximum ESD and dose–area products (DAP), total number of frames, total fluoroscopic time, number of cine runs, cumulative dose at the interventional reference point (IRP), body weight, chest thickness, and height were analyzed. The maximum ESD was 80 ± 59 (mean ± standard deviation) mGy. Maximum ESD closely correlated with both DAP (r = 0.78) and cumulative dose at the IRP (r = 0.82). Maximum ESD for coiling and ballooning tended to be higher than that for ablation, balloon atrial septostomy, and diagnostic procedures. In conclusion, we directly measured ESD using RPLD chips and found that maximum ESD could be estimated in real-time using angiographic parameters, such as DAP and cumulative dose at the IRP. Children requiring repeated catheterizations would be exposed to high radiation levels throughout their lives, although treatment influences radiation dose. Therefore, the radiation dose associated with individual cardiac catheterizations should be analyzed, and the effects of radiation throughout the lives of such patients should be followed. PMID:24968708
2006-01-01
Executive Summary Objective To review the evidence on the effectiveness of hydrophilic catheters for patients requiring intermittent catheterization. Clinical Need There are various reasons why a person would require catheterization, including surgery, urinary retention due to enlargement of the prostate, spinal cord injuries, or other physical disabilities. Urethral catheters are the most prevalent cause of nosocomial urinary tract infections, that is, those that start or occur in a hospital. A urinary tract infection (UTI) occurs when bacteria adheres to the opening of the urethra. Most infections arise from Escherichia coli, from the colon. The bacteria spread into the bladder, resulting in the development of an infection. The prevalence of UTIs varies with age and sex. There is a tenfold increase in incidence for females compared with males in childhood and throughout adult life until around 55 years, when the incidence of UTIs in men and women is equal, mostly as a consequence of prostatic problems in men. Investigators have reported that urethritis (inflammation of the urethra) is found in 2% to 19% of patients practising intermittent catheterization. The Technology Hydrophilic catheters have a polymer coating that binds o the surface of the catheter. When the polymer coating is submersed in water, it absorbs and binds the water to the catheter. The catheter surface becomes smooth and very slippery. This slippery surface remains intact upon insertion into the urethra and maintains lubrication through the length of the urethra. The hydrophilic coating is designed to reduce the friction, as the catheter is inserted with the intention of reducing the risk of urethral damage. It has been suggested that because the hydrophilic catheters do not require manual lubrication they are more sterile and thus less likely to cause infection. Most hydrophilic catheters are prepackaged in sterile water, or there is a pouch of sterile water that is broken and released into the catheter package when the catheter is ready to use. Review Strategy The Medical Advisory Secretariat searched for reports of systematic reviews of randomized controlled trials (RCTs), meta-analyses of RCTs, and RCTs. The following databases were searched: Cochrane Library International Agency for Health Technology Assessment (fourth quarter 2005), Cochrane Database of Systematic Reviews (fourth quarter 2005), Cochrane Central Register of Controlled Trials (fourth quarter 2005), MEDLINE (1966 to the third week of November 2005), MEDLINE In-Process and Other Non-indexed Citations (1966 to November 2005), and EMBASE (1980 to week 49 in 2005). Search terms were urinary catheterization, hydrophilic, intermittent, and bladder catheter. The Medical Advisory Secretariat also conducted Internet searches of Medscape (www.medscape.com) for recent reports on trials that were unpublished but presented at international conferences. In addition, the Web site Current Controlled Trials (www.controlled-trials.com) was searched for ongoing trials on urinary catheterization. Summary of Findings Five RCTs were identified that compared hydrophilic catheters to standard catheters. There was substantial variation across the studies in terms of the reason for catheterization, inclusion criteria, and type of catheter used. Two studies used reusable catheters in the control arm, while the other 3 RCTs used single-use catheters in the control arm. All 5 RCTs focused mainly on males requiring intermittent catheterization. Age varied considerably across studies. One study consisted of young males (mean age 12 years), while another included older males (mean age 71 years). The RCTs reported conflicting results regarding the effectiveness of the hydrophilic catheters compared with standard catheters in terms of rates of UTIs. All 5 RCTs had serious limitations. Two of the studies were small, and likely underpowered to detect significant differences between groups. One RCT reported 12-month follow-up data for all 123 patients even though more than one-half of the patients had dropped out of the study by 12 months. Another RCT had unequal groups at baseline: the patients in the hydrophilic group had twice the mean number of UTIs at baseline compared with the standard catheter group. The fifth RCT used catheters to treat patients with bladder cancer; therefore, the results of their study are not generalizable to the population requiring intermittent catheterization. Two studies did not find significant differences between the hydrophilic and standard catheter groups for patient satisfaction. Another RCT reported conflicting results; however, the overall opinion of the catheters was not significantly different between the treatment groups. A fourth RCT found that the hydrophilic catheters were substantially more comfortable than standard catheters. The fifth RCT did not report results for quality of life or patient satisfaction. Similar to the results for effectiveness, it is not possible to clearly establish if there is a significant difference in patient satisfaction between the patients using hydrophilic catheters and those using standard catheters. Conclusions Patients requiring intermittent catheterization use, on average, 4 to 5 intermittent catheters per day. Patients admitted to hospitals using intermittent catheters typically do not reuse catheters, owing to the potential increased risk of infection in hospital. Patients self-catheterizing at home are more likely to reuse catheters. Standard catheters cost about $1.00 to $1.50/catheter. Hydrophilic catheters cost about $2.00 to $5.00/catheter, depending on the type and whether they have antibiotics inside. All hydrophilic catheters are single-use. At this time there is insufficient evidence to indicate whether hydrophilic catheters are associated with a lower rate of UTIs and improved patient satisfaction among people requiring intermittent catheterization. PMID:23074500
Samad, Zainab; Minter, Stephanie; Armour, Alicia; Tinnemore, Amanda; Sivak, Joseph A; Sedberry, Brenda; Strub, Karen; Horan, Seanna M; Harrison, J Kevin; Kisslo, Joseph; Douglas, Pamela S; Velazquez, Eric J
2016-03-01
The management of aortic stenosis rests on accurate echocardiographic diagnosis. Hence, it was chosen as a test case to examine the utility of continuous quality improvement (CQI) approaches to increase echocardiographic data accuracy and reliability. A novel, multistep CQI program was designed and prospectively used to investigate whether it could minimize the difference in aortic valve mean gradients reported by echocardiography when compared with cardiac catheterization. The Duke Echo Laboratory compiled a multidisciplinary CQI team including 4 senior sonographers and MD faculty to develop a mapped CQI process that incorporated Intersocietal Accreditation Commission standards. Quarterly, the CQI team reviewed all moderate- or greater-severity aortic stenosis echocardiography studies with concomitant catheterization data, and deidentified individual and group results were shared at meetings attended by cardiologists and sonographers. After review of 2011 data, the CQI team proposed specific amendments implemented over 2012: the use of nontraditional imaging and Doppler windows as well as evaluation of aortic gradients by a second sonographer. The primary outcome measure was agreement between catheterization- and echocardiography-derived mean gradients calculated by using the coverage probability index with a prespecified acceptable echocardiography-catheterization difference of <10 mm Hg in mean gradient. Between January 2011 and January 2014, 2093 echocardiograms reported moderate or greater aortic stenosis. Among cases with available catheterization data pre- and post-CQI, the coverage probability index increased from 54% to 70% (P=0.03; 98 cases, year 2011; 70 cases, year 2013). The proportion of patients referred for invasive valve hemodynamics decreased from 47% pre-CQI to 19% post-CQI (P<0.001). A laboratory practice pattern that was amenable to reform was identified, and a multistep modification was designed and implemented that produced clinically valuable performance improvements. The new protocol improved aortic stenosis mean gradient agreement between echocardiography and catheterization and was associated with a measurable decrease in referrals of patients for invasive studies. © 2016 American Heart Association, Inc.
Khot, Umesh N; Johnson, Michele L; Ramsey, Curtis; Khot, Monica B; Todd, Randall; Shaikh, Saeed R; Berg, William J
2007-07-03
Consensus guidelines and hospital quality-of-care programs recommend that ST-elevation myocardial infarction patients achieve a door-to-balloon time of < or = 90 minutes. However, there are limited prospective data on specific measures to significantly reduce door-to-balloon time. We prospectively determined the impact on median door-to-balloon time of a protocol mandating (1) emergency department physician activation of the catheterization laboratory and (2) immediate transfer of the patient to an immediately available catheterization laboratory by an in-house transfer team consisting of an emergency department nurse, a critical care unit nurse, and a chest pain unit nurse. We collected door-to-balloon time for 60 consecutive ST-elevation myocardial infarction patients undergoing emergency percutaneous intervention within 24 hours of presentation from October 1, 2004, through August 31, 2005, and compared this group with 86 consecutive ST-elevation myocardial infarction patients from September 1, 2005, through June 26, 2006, after protocol implementation. Median door-to-balloon time decreased overall (113.5 versus 75.5 minutes; P<0.0001), during regular hours (83.5 versus 64.5 minutes; P=0.005), during off-hours (123.5 versus 77.5 minutes; P<0.0001), and with transfer from an outside affiliated emergency department (147 versus 85 minutes; P=0.0006). Treatment within 90 minutes increased from 28% to 71% (P<0.0001). Mean infarct size decreased (peak creatinine kinase, 2623+/-3329 versus 1517+/-1556 IU/L; P=0.0089), as did hospital length of stay (5+/-7 versus 3+/-2 days; P=0.0097) and total hospital costs per admission ($26,826+/-29,497 versus $18,280+/-8943; P=0.0125). Emergency department physician activation of the catheterization laboratory and immediate transfer of the patient to an immediately available catheterization laboratory reduce door-to-balloon time, leading to a reduction in myocardial infarct size, hospital length of stay, and total hospital costs.
Tsuchiya, Masahiko; Mizutani, Koh; Funai, Yusuke; Nakamoto, Tatsuo
2016-02-01
Ultrasound-guided procedures may be easier to perform when the operator's eye axis, needle puncture site, and ultrasound image display form a straight line in the puncture direction. However, such methods have not been well tested in clinical settings because that arrangement is often impossible due to limited space in the operating room. We developed a wireless remote display system for ultrasound devices using a tablet computer (iPad Mini), which allows easy display of images at nearly any location chosen by the operator. We hypothesized that the in-line layout of ultrasound images provided by this system would allow for secure and quick catheterization of the radial artery. We enrolled first-year medical interns (n = 20) who had no prior experience with ultrasound-guided radial artery catheterization to perform that using a short-axis out-of-plane approach with two different methods. With the conventional method, only the ultrasound machine placed at the side of the head of the patient across the targeted forearm was utilized. With the tablet method, the ultrasound images were displayed on an iPad Mini positioned on the arm in alignment with the operator's eye axis and needle puncture direction. The success rate and time required for catheterization were compared between the two methods. Success rate was significantly higher (100 vs. 70 %, P = 0.02) and catheterization time significantly shorter (28.5 ± 7.5 vs. 68.2 ± 14.3 s, P < 0.001) with the tablet method as compared to the conventional method. An ergonomic straight arrangement of the image display is crucial for successful and quick completion of ultrasound-guided arterial catheterization. The present remote display system is a practical method for providing such an arrangement.
Kasasbeh, Ehab S; Parvez, Babar; Huang, Robert L; Hasselblad, Michele Marie; Glazer, Mark D; Salloum, Joseph G; Cleator, John H; Zhao, David X
2012-11-01
To determine whether radial artery access is associated with a reduction in fluoroscopy time, procedure time, and other procedural variables over a 27-month period during which the radial artery approach was incorporated in a single academic Medical Center. Although previous studies have demonstrated a relationship between increased volume and decreased procedural time, no studies have looked at the integration of radial access over time. Data were collected from consecutive patients who presented to the Vanderbilt University Medical Center cardiac catheterization laboratory from January 1, 2009 to April 1, 2011. Patients who underwent radial access diagnostic catheterization with and without percutaneous coronary intervention were included in this study. A total of 1112 diagnostic cardiac catheterizations through the radial access site were analyzed. High-volume, intermediate-volume, and low-volume operators were grouped based on the percentage of procedures performed through a radial approach. From 2009 to 2011, there was a significant decrease in fluoroscopy time in all operator groups for diagnostic catheterization (P=.035). The high-volume operator group had 1.88 and 3.66 minute reductions in fluoroscopy time compared to the intermediate- and low-volume operator groups, respectively (both P<.001). Likewise, the intermediate-volume operator group had a 1.77 minute improvement compared to the low-volume operator group, but this did not reach statistical significance (P=.102). The improvement in fluoroscopy time and other procedure-related parameters was seen after approximately 25 cases with further improvement after 75 cases. The incorporation of the radial access approach in the cardiac catheterization laboratory led to a decrease in fluoroscopy time for each operator and operator group over the last 3 years. Our data demonstrated that higher-volume radial operators have better procedure, room, and fluoroscopy times when compared to intermediate- and low-volume operators. However, lower-volume operators have a reduction in procedure-related parameters with increased radial cases. Number of procedures needed to become sufficient was demonstrated in the current study.
Shah, Ami P; Cobb, Benjamin T; Lower, Darla R; Shaikh, Nader; Rasmussen, Jayne; Hoberman, Alejandro; Wald, Ellen R; Rosendorff, Adam; Hickey, Robert W
2014-03-01
Urinary tract infections (UTI) are the most common serious bacterial infection in febrile infants. Urinalysis (UA) is a screening test for preliminary diagnosis of UTI. UA can be performed manually or using automated techniques. We sought to compare manual versus automated UA for urine specimens obtained via catheterization in the pediatric emergency department. In this prospective study, we processed catheterized urine samples from infants with suspected UTI by both the manual method (enhanced UA) and the automated method. We defined a positive enhanced UA as ≥ 10 white blood cells per cubic millimeter and presence of any bacteria per 10 oil immersion fields on a Gram-stained smear. We defined a positive automated UA as ≥ 2 white blood cells per high-powered field and presence of any bacteria using the IRIS iQ200 ELITE. We defined a positive urine culture as growth of ≥ 50,000 colony-forming units per milliliter of a single uropathogen. We analyzed data using SPSS software. A total of 703 specimens were analyzed. Prevalence of UTI was 7%. For pyuria, the sensitivity and positive predictive value (PPV) of the enhanced UA in predicting positive urine culture were 83.6% and 52.5%, respectively; corresponding values for the automated UA were 79.5% and 37.5%, respectively. For bacteriuria, the sensitivity and PPV of a Gram-stained smear (enhanced UA) were 83.6% and 59.4%, respectively; corresponding values for the automated UA were 73.4%, and 26.2%, respectively. Using criteria of both pyuria and bacteriuria for the enhanced UA resulted in a sensitivity of 77.5% and a PPV of 84.4%; corresponding values for the automated UA were 63.2% and 51.6%, respectively. Combining automated pyuria (≥ 2 white blood cells/high-powered microscopic field) with a Gram-stained smear resulted in a sensitivity of 75.5% and a PPV of 84%. Automated UA is comparable with manual UA for detection of pyuria in young children with suspected UTI. Bacteriuria detected by automated UA is less sensitive and specific for UTI when compared with a Gram-stained smear. We recommend using either manual or automated measurement of pyuria in combination with Gram-stained smear as the preferred technique for UA of catheterized specimens obtained from children in an acute care setting.
Izzo, Ilaria; Lania, Donatella; Bella, Daniele; Formaini Marioni, Cesare; Coccaglio, Romana; Colombini, Paolo
2015-09-01
Catheter-associated urinary tract infections (CA-UTI) are estimated to be the most frequent nosocomial infections (40%). A catheter is introduced to 10-25% of inpatients, and is often left on site for a long period of time. We carried out a prospective study on inpatients of our Internal Medicine ward to assess the incidence of CA-UTI under the implementation of corrective action. All inpatients who underwent introduction of a urinary catheter upon or after admission to our ward were included in the study. Patients with bacteriuria or positive urine culture before catheterization, others with less than 24 hours catheterism, or bearing a catheter on admission were all excluded from the study. CA-UTI diagnosis was assessed on the basis of CDC 2009 guidelines. The investigation was held between June 2010 and March 2013 in five steps or phases. In the first phase open circuit drainage catheterism was used, in the second phase close circuit drainage catheterism was introduced, while in the third phase disposable lubrification was added to closed circuit drainage catheterism. In the next step (phase 4) we introduced number of days of catheterism control and nurse training; in the last phase (5) emptying urine collection bags on a container was added. In phase 1 we estimated six UTIs out of 18 patients (incidence 33%), in phase 2 we had four infections out of 10 patients (40%). Given the results, we had to reflect on the quality of the procedures of catheter positioning and management . Where feasible, we improved technical practices and during follow-up there was evidence of CA-UTI in 10 patients over 25 (phase 3, 40%), and eight infections over 25 (phase 4, 32%). Once all these steps had been implemented, in phase 5 we determined a sharp reduction in CA-UTI (2 patients over 27, or 7.5%, p=0.025). This improvement was particularly evident in the rate of infection per days of catheter, which was reduced from 43.4/1000 to 13.6/1000. Although the statistical power of the present study has its limitations, we attained a significant reduction in catheter-associated UTIs through the implementation of close circuit catheterism and improvements in care practices.
Ultrasound imaging of the mouse pancreatic duct using lipid microbubbles
NASA Astrophysics Data System (ADS)
Banerjee, B.; McKeown, K. R.; Skovan, B.; Ogram, E.; Ingram, P.; Ignatenko, N.; Paine-Murrieta, G.; Witte, R.; Matsunaga, T. O.
2012-03-01
Research requiring the murine pancreatic duct to be imaged is often challenging due to the difficulty in selectively cannulating the pancreatic duct. We have successfully catheterized the pancreatic duct through the common bile duct in severe combined immune deficient (SCID) mice and imaged the pancreatic duct with gas filled lipid microbubbles that increase ultrasound imaging sensitivity due to exquisite scattering at the gas/liquid interface. A SCID mouse was euthanized by CO2, a midline abdominal incision made, the common bile duct cut at its midpoint, a 2 cm, 32 gauge tip catheter was inserted about 1 mm into the duct and tied with suture. The duodenum and pancreas were excised, removed in toto, embedded in agar and an infusion pump was used to instill normal saline or lipid-coated microbubbles (10 million / ml) into the duct. B-mode images before and after infusion of the duct with microbubbles imaged the entire pancreatic duct (~ 1 cm) with high contrast. The microbubbles were cavitated by high mechanical index (HMI) ultrasound for imaging to be repeated. Our technique of catheterization and using lipid microbubbles as a contrast agent may provide an effective, affordable technique of imaging the murine pancreatic duct; cavitation with HMI ultrasound would enable repeated imaging to be performed and clustering of targeted microbubbles to receptors on ductal cells would allow pathology to be localized accurately. This research was supported by the Experimental Mouse Shared Service of the AZ Cancer Center (Grant Number P30CA023074, NIH/NCI and the GI SPORE (NIH/NCI P50 CA95060).
Vijarnsorn, Chodchanok; Rutledge, Jennifer M; Tham, Edythe B; Coe, James Y; Quinonez, Luis; Patton, David J; Noga, Michelle
2014-02-01
Children with right ventricular outflow tract obstructive (RVOTO) lesions require precise quantification of pulmonary artery (PA) size for proper management of branch PA stenosis. We aimed to determine which cardiovascular magnetic resonance (CMR) sequences and planes correlated best with cardiac catheterization and surgical measurements of branch PA size. Fifty-five children with RVOTO lesions and biventricular circulation underwent CMR prior to; either cardiac catheterization (n = 30) or surgery (n = 25) within a 6 month time frame. CMR sequences included axial black blood, axial, coronal oblique and sagittal oblique cine balanced steady-state free precession (bSSFP), and contrast-enhanced magnetic resonance angiography (MRA) with multiplanar reformatting in axial, coronal oblique, sagittal oblique, and cross-sectional planes. Maximal branch PA and stenosis (if present) diameter were measured. Comparisons of PA size on CMR were made to reference methods: (1) catheterization measurements performed in the anteroposterior plane at maximal expansion, and (2) surgical measurement obtained from a maximal diameter sound which could pass through the lumen. The mean differences (Δ) and intra class correlation (ICC) were used to determine agreement between different modalities. CMR branch PA measurements were compared to the corresponding cardiac catheterization measurements in 30 children (7.6 ± 5.6 years). Reformatted MRA showed better agreement for branch PA measurement (ICC > 0.8) than black blood (ICC 0.4-0.6) and cine sequences (ICC 0.6-0.8). Coronal oblique MRA and maximal cross sectional MRA provided the best correlation of right PA (RPA) size with ICC of 0.9 (Δ -0.1 ± 2.1 mm and Δ 0.5 ± 2.1 mm). Maximal cross sectional MRA and sagittal oblique MRA provided the best correlate of left PA (LPA) size (Δ 0.1 ± 2.4 and Δ -0.7 ± 2.4 mm). For stenoses, the best correlations were from coronal oblique MRA of right pulmonary artery (RPA) (Δ -0.2 ± 0.8 mm, ICC 0.9) and sagittal oblique MRA of left pulmonary artery (LPA) (Δ 0.2 ± 1.1 mm, ICC 0.9). CMR PA measurements were compared to surgical measurements in 25 children (5.4 ± 4.8 years). All MRI sequences demonstrated good agreement (ICC > 0.8) with the best (ICC 0.9) from axial cine bSSFP for both RPA and LPA. Maximal cross sectional and angulated oblique reformatted MRA provide the best correlation to catheterization for measurement of branch PA's and stenosis diameter. This is likely due to similar angiographic methods based on reformatting techniques that transect the central axis of the arteries. Axial cine bSSFP CMR was the best surgically measured correlate of PA branch size due to this being a measure of stretched diameter. Knowledge of these differences provides more precise PA measurements and may aid catheter or surgical interventions for RVOTO lesions.
Viral Oncolytic Therapeutics for Neoplastic Meningitis
2014-09-01
our animal vendor, Charles River Laboratories (CRL), to adopt their intrathecal catheterization service for this purpose. Cannulated animals from CRL...pilot “idea” study. Thus, both experimental approaches, catheterization did not allow us to obtain statistically significant therapeutic efficacy...fluid, which will help developing new approaches for delivery of therapies, in particular biopharmaceuticals, to the central nervous system and
Part versus Whole: A Randomized Trial of Central Venous Catheterization Education
ERIC Educational Resources Information Center
Chan, Angela; Singh, Sunita; Dubrowski, Adam; Pratt, Daniel D.; Zalunardo, Nadia; Nair, Parvarthy; McLaughlin, Kevin; Ma, Irene W. Y.
2015-01-01
Central venous catheterization (CVC) is a complex but commonly performed procedure. How best to teach this complex skill has not been clearly delineated. We conducted a randomized trial of the effects of two types of teaching of CVC on skill acquisition and retention. We randomly assigned novice internal medicine residents to learning CVC in-part…
Ma, Hong; Xie, Rong-Ai; Gao, Li-Jian; Zhang, Jin-Ping; Wu, Wei-Chun; Wang, Hao
2015-10-01
The purpose of this study was to investigate the diagnostic value of 3-dimensional (3D) speckle-tracking echocardiography for estimating left ventricular filling pressure in patients with coronary artery disease (CAD) and a preserved left ventricular ejection fraction. Altogether, 84 patients with CAD and 30 age- and sex-matched healthy control participants in sinus rhythm were recruited prospectively. All participants underwent conventional and 3D speckle-tracking echocardiography. Global strain values were automatically calculated by 3D speckle-tracking analysis. The left ventricular end-diastolic pressure (LVEDP) was determined invasively by left heart catheterization. Echocardiography and cardiac catheterization were performed within 24 hours. Compared with the controls, patients with CAD showed lower global longitudinal strain, global circumferential strain, global area strain, and global radial strain. Patients with CAD who had an elevated LVEDP had much lower levels of all 4 3D-speckle-tracking echocardiographic variables. Pearson correlation analysis revealed that the LVEDP correlated positively with the early transmitral flow velocity/early diastolic myocardial velocity (E/E') ratio, global longitudinal strain, global circumferential strain, and global area strain. It correlated negatively with global radial strain. Receiver operating characteristic curve analysis revealed that these 3D speckle-tracking echocardiographic indices could effectively predict elevated left ventricular filling pressure (LVEDP >15 mm Hg) in patients with CAD (areas under the curve: global longitudinal strain, 0.78; global radial strain, 0.77; global circumferential strain, 0.75; and global area strain, 0.74). These parameters, however, showed no advantages over the commonly used E/E' ratio (area under the curve, 0.84). Three-dimensional speckle-tracking echocardiography was a practical technique for predicting elevated left ventricular filling pressure, but it might not be superior to the commonly used E/E' ratio in patients with CAD who have a normal left ventricular ejection fraction. © 2015 by the American Institute of Ultrasound in Medicine.
Right ventricular stroke work correlates with outcomes in pediatric pulmonary arterial hypertension.
Yang, Weiguang; Marsden, Alison L; Ogawa, Michelle T; Sakarovitch, Charlotte; Hall, Keeley K; Rabinovitch, Marlene; Feinstein, Jeffrey A
2018-01-01
Pulmonary arterial hypertension (PAH) is characterized by elevated pulmonary artery pressures (PAP) and pulmonary vascular resistance (PVR). Optimizing treatment strategies and timing for transplant remains challenging. Thus, a quantitative measure to predict disease progression would be greatly beneficial in treatment planning. We devised a novel method to assess right ventricular (RV) stroke work (RVSW) as a potential biomarker of the failing heart that correlates with clinical worsening. Pediatric patients with idiopathic PAH or PAH secondary to congenital heart disease who had serial, temporally matched cardiac catheterization and magnetic resonance imaging (MRI) data were included. RV and PA hemodynamics were numerically determined by using a lumped parameter (circuit analogy) model to create pressure-volume (P-V) loops. The model was tuned using optimization techniques to match MRI and catheterization derived RV volumes and pressures for each time point. RVSW was calculated from the corresponding P-V loop and indexed by ejection fraction and body surface area (RVSW EF ) to compare across patients. Seventeen patients (8 boys; median age = 9.4 years; age range = 4.4-16.3 years) were enrolled. Nine were clinically stable; the others had clinical worsening between the time of their initial matched studies and their most recent follow-up (mean time = 3.9 years; range = 1.1-8.0 years). RVSW EF and the ratio of pulmonary to systemic resistance (Rp:Rs) values were found to have more significant associations with clinical worsening within one, two, and five years following the measurements, when compared with PVR index (PVRI). A receiver operating characteristic analysis showed RVSW EF outperforms PVRI, Rp:Rs and ejection fraction for predicting clinical worsening. RVSW EF correlates with clinical worsening in pediatric PAH, shows promising results towards predicting adverse outcomes, and may serve as an indicator of future clinical worsening.
Franek, Jacob; Leibach, Elizabeth K.; Weissfeld, Alice S.; Kraft, Colleen S.; Sautter, Robert L.; Baselski, Vickie; Rodahl, Debra; Peterson, Edward J.; Cornish, Nancy E.
2015-01-01
SUMMARY Background. Urinary tract infection (UTI) in the United States is the most common bacterial infection, and urine cultures often make up the largest portion of workload for a hospital-based microbiology laboratory. Appropriately managing the factors affecting the preanalytic phase of urine culture contributes significantly to the generation of meaningful culture results that ultimately affect patient diagnosis and management. Urine culture contamination can be reduced with proper techniques for urine collection, preservation, storage, and transport, the major factors affecting the preanalytic phase of urine culture. Objectives. The purposes of this review were to identify and evaluate preanalytic practices associated with urine specimens and to assess their impact on the accuracy of urine culture microbiology. Specific practices included collection methods for men, women, and children; preservation of urine samples in boric acid solutions; and the effect of refrigeration on stored urine. Practice efficacy and effectiveness were measured by two parameters: reduction of urine culture contamination and increased accuracy of patient diagnosis. The CDC Laboratory Medicine Best Practices (LMBP) initiative's systematic review method for assessment of quality improvement (QI) practices was employed. Results were then translated into evidence-based practice guidelines. Search strategy. A search of three electronic bibliographic databases (PubMed, SCOPUS, and CINAHL), as well as hand searching of bibliographies from relevant information sources, for English-language articles published between 1965 and 2014 was conducted. Selection criteria. The search contained the following medical subject headings and key text words: urinary tract infections, UTI, urine/analysis, urine/microbiology, urinalysis, specimen handling, preservation, biological, preservation, boric acid, boric acid/borate, refrigeration, storage, time factors, transportation, transport time, time delay, time factor, timing, urine specimen collection, catheters, indwelling, urinary reservoirs, continent, urinary catheterization, intermittent urethral catheterization, clean voided, midstream, Foley, suprapubic, bacteriological techniques, and microbiological techniques. Main results. Both boric acid and refrigeration adequately preserved urine specimens prior to their processing for up to 24 h. Urine held at room temperature for more than 4 h showed overgrowth of both clinically significant and contaminating microorganisms. The overall strength of this body of evidence, however, was rated as low. For urine specimens collected from women, there was no difference in rates of contamination for midstream urine specimens collected with or without cleansing. The overall strength of this evidence was rated as high. The levels of diagnostic accuracy of midstream urine collection with or without cleansing were similar, although the overall strength of this evidence was rated as low. For urine specimens collected from men, there was a reduction in contamination in favor of midstream clean-catch over first-void specimen collection. The strength of this evidence was rated as high. Only one study compared midstream collection with cleansing to midstream collection without cleansing. Results showed no difference in contamination between the two methods of collection. However, imprecision was due largely to the small event size. The diagnostic accuracy of midstream urine collection from men compared to straight catheterization or suprapubic aspiration was high. However, the overall strength of this body of evidence was rated as low. For urine specimens collected from children and infants, the evidence comparing contamination rates for midstream urine collection with cleansing, midstream collection without cleansing, sterile urine bag collection, and diaper collection pointed to larger reductions in the odds of contamination in favor of midstream collection with cleansing over the other methods of collection. This body of evidence was rated as high. The accuracy of diagnosis of urinary tract infection from midstream clean-catch urine specimens, sterile urine bag specimens, or diaper specimens compared to straight catheterization or suprapubic aspiration was varied. Authors' conclusions. No recommendation for or against is made for delayed processing of urine stored at room temperature, refrigerated, or preserved in boric acid. This does not preclude the use of refrigeration or chemical preservatives in clinical practice. It does indicate, however, that more systematic studies evaluating the utility of these measures are needed. If noninvasive collection is being considered for women, midstream collection with cleansing is recommended, but no recommendation for or against is made for midstream collection without cleansing. If noninvasive collection is being considered for men, midstream collection with cleansing is recommended and collection of first-void urine is not recommended. No recommendation for or against is made for collection of midstream urine without cleansing. If noninvasive collection is being considered for children, midstream collection with cleansing is recommended and collection in sterile urine bags, from diapers, or midstream without cleansing is not recommended. Whether midstream collection with cleansing can be routinely used in place of catheterization or suprapubic aspiration is unclear. The data suggest that midstream collection with cleansing is accurate for the diagnosis of urinary tract infections in infants and children and has higher average accuracy than sterile urine bag collection (data for diaper collection were lacking); however, the overall strength of evidence was low, as multivariate modeling could not be performed, and thus no recommendation for or against can be made. PMID:26598386
Patent ductus arteriosus in adults: surgical experience in Ivory-Coast.
Yangni-Angate, H; Ayegnon, G; Meneas, C; Diby, F L; Yapobi, Y
2007-03-01
Patent ductus arteriosus surgery is well documented. Hospital Mortality has reduced to almost 0%. Yet, with adults, this surgical cure is likely to be difficult and require some technical skills A retrospective study of surgical procedures and results after surgery of patent ductus arteriosus (PDA) in adults. Since 1978 to 2000 we have reported 16 operated cases. The average age was 22.5 years. There was female predominance with a sex ratio of 2.3/1. All patent ductus arteriosus had been confirmed by two dimensional echocardiography (2D echocardiography) and cardiac catheterization. All hemodynamic types of Nadas classification were observed. Double or triple ligation supported on Teflon felt was the most frequent technique used (69%). This technique gave good results in view of the absence of hospital mortality and only 1 case of recanalisation after a long follow up of all patients from 1 - 7 years (mean 5 years). Double or triple ligation on Teflon felt according to Wright technique is a good technique.
Levenson, B; Albrecht, A; Göhring, St; Haerer, W; Herholz, H; Reifart, N; Sauer, G; Troger, B
2007-02-01
On behalf of the German Association of Cardiologists in Private Practice (BNK) the Steering Committee of the QuIK Registry reports on the results of the voluntary quality assurance in invasive cardiology in 2003-2005 and compares it to other data collections. In 2005 more than 70% of diagnostic (LHK) and 78% of therapeutic (PCI) cardiac catheterization procedures in private practice were entered into the registry. Altogether 229,462 LHK and 64,818 PCI were documented over the 3 years. In the reported period age of patients, percentage of acute coronary syndromes and three-vessel coronary artery disease increased in LHK as well as in PCI while consumption of contrast media and fluoroscopy time decreased. By implemented possibility of follow-up, a high rate of external auditing (monitoring) and certification QuIK remains a worldwide unique quality assurance project in cardiology. On a stable data basis over 10 years the QuIK Registry enables the implementation of quality indicators for future quality assurance purposes.
Effects of vasoactive intestinal peptide on vascular conductance are unaffected by anesthesia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bouder, T.G.; Huffman, L.J.; Hedge, G.A.
1988-12-01
In rats anesthetized with ketamine and pentobarbital (KET/PB), vasoactive intestinal peptide (VIP) increases vascular conductance (VC) in the salivary gland, pancreas, and thyroid gland, whereas no changes in VC are observed in a number of other organs. Because anesthesia may alter the responsiveness of physiological systems, we compared the effects of VIP on organ VC in conscious or anesthetized rats. Chronically catheterized rats were studied in the conscious state or 30 min after induction of anesthesia with KET/PB, isoflurane, or Inactin. Blood flows were measured by the reference sample version of the radioactive microsphere (MS) technique using two MS injectionsmore » ({sup 141}Ce-MS/{sup 85}Sr-MS). Mean arterial blood pressure was monitored and used in the calculation of VC. Organ VCs were similar under basal conditions in conscious and anesthetized rats. VIP infusion caused systemic hypotension and increased VCs in the salivary gland, pancreas, and thyroid gland, and these responses were largely unaffected by anesthesia. These results indicate that the anesthetics used do not alter basal VC or the responsiveness of the vasculature to exogenous VIP.« less
Role of transcatheter arterial embolization for massive bleeding from gastroduodenal ulcers
Loffroy, Romaric; Guiu, Boris
2009-01-01
Intractable bleeding from gastric and duodenal ulcers is associated with significant morbidity and mortality. Aggressive treatment with early endoscopic hemostasis is essential for a favourable outcome. In as many as 12%-17% of patients, endoscopy is either not available or unsuccessful. Endovascular therapy with selective catheterization of the culprit vessel and injection of embolic material has emerged as an alternative to emergent operative intervention in high-risk patients. There has not been a systematic literature review to assess the role for embolotherapy in the treatment of acute upper gastrointestinal bleeding from gastroduodenal ulcers after failed endoscopic hemostasis. Here, we present an overview of indications, techniques, and clinical outcomes after endovascular embolization of acute peptic-ulcer bleeding. Topics of particular relevance to technical and clinical success are also discussed. Our review shows that transcatheter arterial embolization is a safe alternative to surgery for massive gastroduodenal bleeding that is refractory to endoscopic treatment, can be performed with high technical and clinical success rates, and should be considered the salvage treatment of choice in patients at high surgical risk. PMID:20014452
Transradial Approach as a Default Route in Coronary Artery Interventions
Kim, Jang-Young
2011-01-01
Advances in percutaneous coronary intervention (PCI) and peri-procedural potent antithrombotic treatments during the past decade have dramatically improved the outcomes of ischemic heart disease. The femoral artery is the vascular route used in PCI in most catheterization labs. However, when the femoral artery is used as the approaching vessel, local hemorrhagic complication is not rare in the era of potent antithrombotics. Recent studies have suggested that peri-procedural bleeding complications after PCI are associated with increased short- and long-term morbidity and mortality. On the other hand, there has been growing interest in transradial PCI due to rare complications at the puncture site, patient conveniences, early discharge and shortened hospitalization periods. Furthermore, the indications of transradial PCI are expanding to the complex lesion subsets due to the miniaturization of devices used, improvement of devices and techniques, and accumulated experience with the use of transradial PCI. In this review, we discuss the data of transradial PCI as a potential default route in coronary artery interventions, as well as other issues that may raise concerns with transradial PCI. PMID:21359061
Transradial approach as a default route in coronary artery interventions.
Kim, Jang-Young; Yoon, Junghan
2011-01-01
Advances in percutaneous coronary intervention (PCI) and peri-procedural potent antithrombotic treatments during the past decade have dramatically improved the outcomes of ischemic heart disease. The femoral artery is the vascular route used in PCI in most catheterization labs. However, when the femoral artery is used as the approaching vessel, local hemorrhagic complication is not rare in the era of potent antithrombotics. Recent studies have suggested that peri-procedural bleeding complications after PCI are associated with increased short- and long-term morbidity and mortality. On the other hand, there has been growing interest in transradial PCI due to rare complications at the puncture site, patient conveniences, early discharge and shortened hospitalization periods. Furthermore, the indications of transradial PCI are expanding to the complex lesion subsets due to the miniaturization of devices used, improvement of devices and techniques, and accumulated experience with the use of transradial PCI. In this review, we discuss the data of transradial PCI as a potential default route in coronary artery interventions, as well as other issues that may raise concerns with transradial PCI.
Ascending Aortic Stenting for Acute Supraaortic Stenosis From Graft Collapse.
Lader, Joshua M; Smith, Deane E; Staniloae, Cezar; Fallahi, Arzhang; Iqbal, Sohah N; Galloway, Aubrey C; Williams, Mathew R
2018-06-01
A 78-year-old man with remote type-A dissection presented with acute-onset dyspnea. Twenty-two years prior, treatment for his aortic disease required replacement of ascending and arch aneurysms with a polyester graft (Dacron) using the graft inclusion technique. He presented currently in cardiogenic shock. Echocardiography demonstrated new severe hypokinesis of all apical segments. Left-heart catheterization revealed a 120 mm Hg intragraft gradient. Computed tomography arteriography was unrevealing, but intraaortic ultrasound demonstrated critical intragraft stenosis. A balloon expandable stent (Palmaz stent, Cordis, Milpitas, CA) was deployed in the stenotic region with gradient resolution. The patient later underwent aortic root replacement and ascending aneurysm repair (Bio-Bentall technique) and is doing well at 24 months. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Heudorf, Ursel; Gasteyer, Stefanie; Müller, Maria; Samoiski, Yvonne; Serra, Nicole; Westphal, Tim
2016-01-01
Urinary tract infections range among the most frequent infections not only in hospital patients but also in residents of long-term care facilities for the elderly. Urinary catheters are the greatest risk factor for urinary tract infections. In the guidance paper on the "prevention of infections in nursing homes" (2005) as well as in the updated recommendations for the "prevention and control of catheter-associated urinary tract infections" (2015), the Commission for Hospital Hygiene and Infection Prevention (KRINKO) has recommended adequate preventive measures. In 2015, the implementation of these KRINKO recommendations was investigated. All of Frankfurt's 40 nursing homes were evaluated using a checklist based on the KRINKO recommendations. The evaluation included assessing the availability of operating instructions, appropriate indications for the placement of catheters etc. Age, sex and duration of catheterization, as well as current and previous infections within the past 6 months were documented for every resident with a catheter. In 35 (87.5%) of the nursing homes, operating instructions for the handling of urinary tract catheters were available. The decision as to whether a catheter is indicated is made by physicians, while its placement is often delegated to the nursing service. Typically, silicon catheters are used. In three-quarters of the nursing homes, regular intervals of 4-6 weeks for changing catheters were reported. On the respective survey day, 7.3% of the residents were catheterized. On the survey day, 3.6% (4.2%) and in the previous 6 months a total of 28% (28.9%) of the residents had a urinary tract infection (prevalence of antibiotic therapy in parentheses). Ciprofloxacin was used most often followed by cefuroxime and cotrimoxazole. In the current evaluation, fewer nursing home residents were catheterized than in previous years and the rate of urinary tract infections was low. This indicates an increasingly cautious and apparently appropriate usage of urinary tract catheters. Also, the prevalence of antibiotic therapy was low for residents with urinary tract catheters (4.2%). However, broad spectrum antibiotics are still preferentially administered (particularly quinolones), which may favor the high rate of colonization with ESBL-producing bacteria and 3MRGN. Given this background, a coordinated approach including resistance-based antibiotic stewardship appears increasingly important in nursing homes and other health care facilities.
Kwan, Tak W; Patel, Apurva; Parikh, Roosha; Auguste, Uschi; Rosero, Hugo; Huang, Yili; Liou, Michael; Ratcliffe, Justin; Puma, Joseph
2016-08-01
Transpedal access is increasingly utilized for peripheral vascular catheterization. There is a paucity of data on the use of radial hemostasis devices as an alternative to manual compression for achievement of hemostasis after this approach. To compare safety and efficacy of two hemostasis devices following transpedal catheterization for lower extremity revascularization for peripheral arterial disease. A consecutive cohort of patients with bilateral Rutherford 2-5 disease who underwent transpedal catheterization for peripheral vascular interventions were retrospectively analyzed. In each patient, retrograde tibial artery access was obtained, a 4 French sheath was placed, and all revascularization was performed via tibial access. In all patients, a TR Band™ (Terumo Medical, n = 215) and/or VasoStat™ (Forge Medical, n = 99) were used to apply puncture site compression, following removal of the tibial sheath until hemostasis was achieved. Safety and efficacy of each device was compared. Puncture site hemostasis was achieved in all patients within 2 hours of sheath removal facilitating early discharge. Two access site pseudoaneurysms occurred within 30 days of revascularization, one of which followed TR Band™ placement and the other following VasoStat™ placement (P = 0.53). Each patient was successfully treated with ultrasound-guided thrombin injection. Loss of access site patency by duplex ultrasound occurred in 2 patients following the TR Band™ and a single patient following the VasoStat™ (P = 1.0). Both the TR Band™ and the VasoStat™ were effective in achieving hemostasis following transpedal catheterization with low rates of complications. © 2016, Wiley Periodicals, Inc.
Zaer, Hamed; Rasmussen, Mikkel Mylius; Zepke, Franko; Bodin, Charlotte; Domurath, Burkhard; Kutzenberger, Johannes
2018-05-10
Spinal cord injury (SCI) is a highly devastating injury with a variety of complications; among them are neurogenic bladder, bowel, and sexual dysfunction. We aimed to evaluate the effect of sacral anterior root stimulation with sacral deafferentation (SARS-SDAF) on neurogenic bladder and sexual dysfunction in a large well-defined spinal cord injury cohort. In the manner of cross-sectional study, subjects undergone SARS-SDAF between September 1986 and July 2011 answered a questionnaire concerning conditions before and after surgery in the department of Neuro-Urology, Bad Wildungen, Germany. In total 287 of 587 subjects were analyzed. Median age was 49 years (range 19-80), median time from SCI to surgery was 10 years (range 0-49), and from surgery to follow-up 13 years (range 1-25). Of the analyzed subjects, 100% of both gender used SARS for bladder emptying. On the visual analogue scale (VAS) ranging from 0 to 10 (best), satisfaction with SARS-SDAF was 10 concerning bladder emptying, however 5 and 8 regarding sexual performance, for female and male users, respectively. Baseline and follow-up comparison showed a decline in self-intermittent catheterization (p < 0.0001), partial catheterization by attendant (p = 0.0125), complete catheterization and suprapubic catheterization (p < 0.0001), transurethral catheterization (p < 0.0011), and fewer cases of involuntary urine leakage (p < 0.0001). The SARS-SDAF is a beneficial multi-potential treatment method with simultaneous positive effect on multi-organ dysfunction among SCI subjects.
Maddox, Thomas M; Plomondon, Mary E; Petrich, Megan; Tsai, Thomas T; Gethoffer, Hans; Noonan, Gregory; Gillespie, Brian; Box, Tamara; Fihn, Stephen D; Jesse, Robert L; Rumsfeld, John S
2014-12-01
A "learning health care system", as outlined in a recent Institute of Medicine report, harnesses real-time clinical data to continuously measure and improve clinical care. However, most current efforts to understand and improve the quality of care rely on retrospective chart abstractions complied long after the provision of clinical care. To align more closely with the goals of a learning health care system, we present the novel design and initial results of the Veterans Affairs (VA) Clinical Assessment, Reporting, and Tracking (CART) program-a national clinical quality program for VA cardiac catheterization laboratories that harnesses real-time clinical data to support clinical care and quality-monitoring efforts. Integrated within the VA electronic health record, the CART program uses a specialized software platform to collect real-time patient and procedural data for all VA patients undergoing coronary procedures in VA catheterization laboratories. The program began in 2005 and currently contains data on 434,967 catheterization laboratory procedures, including 272,097 coronary angiograms and 86,481 percutaneous coronary interventions, performed by 801 clinicians on 246,967 patients. We present the initial data from the CART program and describe 3 quality-monitoring programs that use its unique characteristics-procedural and complications feedback to individual labs, coronary device surveillance, and major adverse event peer review. The VA CART program is a novel approach to electronic health record design that supports clinical care, quality, and safety in VA catheterization laboratories. Its approach holds promise in achieving the goals of a learning health care system. Published by Elsevier Inc.
Intraoperative sonographic assessment of graft patency during extracranial-intracranial bypass.
Badie, B; Lee, F T; Pozniak, M A; Strother, C M
2000-09-01
Extracranial-intracranial (EC-IC) bypass may be necessary to facilitate treatment of unclippable posterior circulation fusiform aneurysms. Although intraoperative digital subtraction angiography (DSA) allows assessment of graft patency, this technique, because of difficulties inherent in performing selective catheterization and angiography in the operating room, has limitations. Duplex sonography, in contrast, is easily performed, and provides information regarding graft patency and blood flow direction during EC-IC bypass procedures. This latter information proved useful in determining the time of parent artery occlusion after two EC-IC bypass procedures performed for treatment of a fusiform midbasilar artery aneurysm.
Management of coronary artery disease
NASA Astrophysics Data System (ADS)
Safri, Z.
2018-03-01
Coronary Artery Disease (CAD) is associated with significant morbidity and mortality, therefore it’s important to early and accurate detection and appropriate management. Diagnosis of CAD include clinical examination, noninvasive techniques such as biochemical testing, a resting ECG, possibly ambulatory ECG monitoring, resting echocardiography, chest X-ray in selected patients; and catheterization. Managements of CAD patients include lifestyle modification, control of CAD risk factors, pharmacologic therapy, and patient education. Revascularization consists of percutaneous coronary angioplasty and coronary artery bypass grafting. Cardiac rehabilitation should be considered in all patients with CAD. This comprehensive review highlights strategies of management in patients with CAD.
Open vs Laparoscopic Simple Prostatectomy: A Comparison of Initial Outcomes and Cost.
Demir, Aslan; Günseren, Kadir Ömür; Kordan, Yakup; Yavaşçaoğlu, İsmet; Vuruşkan, Berna Aytaç; Vuruşkan, Hakan
2016-08-01
We compared the cost-effectiveness of laparoscopic simple prostatectomy (LSP) vs open prostatectomy (OP). A total of 73 men treated for benign prostatic hyperplasia were enrolled for OP and LSP in groups 1 and 2, respectively. The findings were recorded perioperative, including operation time (OT), blood lost, transfusion rate, conversion to the open surgery, and the complications according to the Clavien Classification. The postoperative findings, including catheterization and drainage time, the amount of analgesic used, hospitalization time, postoperative complications, international prostate symptom score (IPSS) and International Index of Erectile Function (IIEF) scores, the extracted prostate weight, the uroflowmeter, as well as postvoiding residual (PVR) and quality of life (QoL) score at the postoperative third month, were analyzed. The cost of both techniques was also compared statistically. No statistical differences were found in the preoperative parameters, including age, IPSS and QoL score, maximum flow rate (Qmax), PVR, IIEF score, and prostate volumes, as measured by transabdominal ultrasonography. No statistical differences were established in terms of the OT and the weight of the extracted prostate. No differences were established with regard to complications according to Clavien's classification in groups. However, the bleeding rate was significantly lower in group 2. The drainage, catheterization, and hospitalization times and the amount of analgesics were significantly lower in the second group. The postoperative third month findings were not different statistically. Only the Qmax values were significantly greater in group 2. While there was only a $52 difference between groups with regard to operation cost, this difference was significantly different. The use of LSP for the prostates over 80 g is more effective than the OP in terms of OT, bleeding amount, transfusion rates, catheterization time, drain removal time, hospitalization time, consumed analgesic amount, and Qmax values. On the other hand, the mean cost of the LSP is higher than OP. Better effectiveness comes with higher cost.
2017-01-01
Purpose Clean intermittent self-catheterization (CISC) is now considered the gold standard for the management of urinary retention. In the literature, several articles on patients’ perspectives on CISC and adherence to this technique have been published. No studies have yet explored the points of view of professional caregivers, such as nurses and doctors. The aim of this study was to explore the opinions of urologists about CISC and to evaluate the need for dedicated nurses specialized in CISC through a self-administered questionnaire. Methods A questionnaire was developed to explore the opinions of professional caregivers about self-catheterization and to evaluate the need to provide nurses with specialized education in CISC. Questionnaires were sent to 244 urologists through email. We received 101 completed questionnaires. The response rate was 41.4%. Results Hand function, the presence or absence of tremor, and visual acuity were rated as the most important determinants for proposing CISC to a patient. Twenty-five percent of the urologists reported that financial remuneration would give them a greater incentive to propose CISC. The lack of dedicated nurses was reported by half of the urologists as a factor preventing them from proposing CISC. A meaningful number of urologists thought that patients perceive CISC as invasive and unpleasant. Although most urologists would choose CISC as a treatment option for themselves, almost 1 urologist out of 5 would prefer a permanent catheter. Conclusions This questionnaire gave valuable insights into urologists’ perceptions of CISC, and could serve as the basis for a subsequent broader international study. Further research should also focus on the opinions of nurses and other caregivers involved in incontinence management. Apart from financial remuneration, it is also clear that ensuring sufficient expertise and time for high-quality CISC care is important. This could be a potential role for dedicated nurses. PMID:28954460
Ince, Ilker; Arı, Muhammet Ali; Sulak, Muhammet Mustafa; Aksoy, Mehmet
There are different ultrasound probe positions used for internal jugular venous catheter placement. Also, in-plane or out of plane needle approach may be used for catheterization. Transverse short-axis classic approach is the most popular performed approach in literature. "Syringe-Free" is a new described technique that is performed with oblique long-axis approach. We aimed to compare performance of these two approaches. This study was conducted as a prospective and randomized study. 80 patients were included the study and divided into two groups that were named Group C (transverse short-axis classic approach) and Group SF (oblique long-axis syringe-free approach) by a computer-generated randomization. The primary outcome was mean time that guidewire is seen in the internal jugular vein (performing time). The secondary outcomes were to compare number of needle pass, number of skin puncture and complications between two groups. Demographic and hemodynamic data were not significantly different. The mean performing time was 54.9±19.1s in Group C and 43.9±15.8s in Group SF. Significant differences were found between the groups (p=0.006). Mean number of needle pass was 3.2(±2.1) in Group C and 2.1(±1.6) in Group SF. There were statistically significant differences between two groups (p=0.002). The number of skin puncture was 1.6(±0.8) and 1.2(±0.5) in Group C and SF, respectively (p=0.027). "Syringe-Free" technique has lower performing time, number of needle pass and skin puncture. Also, it allows to follow progress of guide-wire under continuous ultrasound visualization and the procedure does not need assistance during catheter insertion. Namely, "Syringe-Free" is effective, safe and fast technique that may be used to place internal jugular venous catheter. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.
Botulinum toxin in spinal cord injury patients with neurogenic detrusor overactivity
Cho, Young Sam; Kim, Khae Hawn
2016-01-01
Evidence for the efficacy and safety of intravesical onabotulinum toxin A (onabotA) injections has led to them being licensed in many countries, including Korea, for the treatment of patients with urinary incontinence due to neurogenic detrusor overactivity (NDO) resulting from spinal cord injury or multiple sclerosis who are refractory or intolerant to anticholinergic medications. OnabotA injections have an inhibitory effect on acetylcholine release for up to 10 months, with a recommended dose of 200 U. OnabotA treatment has a beneficial effect not only on urinary symptoms, but also on quality of life. Several clinical studies have shown onabotA to have better effects than placebo in achieving continence, reducing incontinence episodes, improving urodynamic parameters, and improving health-related quality of life. Urinary tract infections and postvoid residual volume are the most prevalent side effects. In patients with residual volume, clean intermittent catheterization may be necessary. In patients with spinal cord injury or multiple sclerosis, it is recommended to evaluate physical and cognitive function before intravesical onabotA injection to ensure that the patient and caregiver are able to perform catheterization if necessary. Further controlled trials should assess the optimal dose, injection technique, long-term safety of repeated injections, and optimal timing of onabotA treatment in the treatment of NDO. PMID:28119887
Lim, Byung Gun; Kim, Young Min; Kim, Heezoo; Lim, Sang Ho; Lee, Mi Kyoung
2011-12-01
A 41-year-old woman, who had no thrombotic risk factors and past history except congenital scoliosis, underwent central venous catheterization (CVC) before correction of the scoliosis. When internal jugular vein (IJV) catheterization using the anatomical landmark technique failed, CVC under ultrasound guidance was tried. As a consequence, thrombosis and hypoplasia of the right IJV were incidentally detected by ultrasonography. Central venous catheters were then successfully placed in other veins under ultrasound guidance. Also, after examinations to rule out the possibility of pulmonary embolism and to clarify the causes of the IJV thrombosis, the patient was found to have protein S deficiency. CVC under ultrasound guidance should be recommended to prevent the failure of cannulation and complications such as thromboembolism in patients who could possibly have anomalies of vessels as a result of anatomical deformities caused by severe scoliosis, even if patients do not have thrombotic risk factors such as a history of central catheter insertion or intravenous drug abuse, cancer, advanced age, cerebral infarction, and left ventricular dysfunction. Also, if venous thrombosis is found in patients without predisposing risk factors, one should ascertain the cause of the hypercoagulable state, for example protein S deficiency, and perform appropriate treatment and prevention of venous thromboembolism.
Holá, Veronika; Ruzicka, Filip; Horka, Marie
2010-08-01
Infections of the urinary tract account for >40% of nosocomial infections; most of these are infections in catheterized patients. Bacterial colonization of the urinary tract and catheters causes not only the particular infection but also a number of complications, for example blockage of catheters with crystallic deposits of bacterial origin, generation of gravels and pyelonephritis. Infections of urinary catheters are only rarely single-species infections. The longer a patient is catheterized, the higher the diversity of biofilm microbial communities. The aims of this study were to investigate the microbial diversity on the catheters and to compare the ability to form biofilm among isolated microbial species. The next aim was to discriminate particular causative agents of infections of the urinary tract and their importance as biofilm formers in the microbial community on the urinary catheter. We examined catheters from 535 patients and isolated 1555 strains of microorganisms. Most of the catheters were infected by three or more microorganisms; only 12.5% showed monomicrobial infection. Among the microorganisms isolated from the urinary catheters, there were significant differences in biofilm-forming ability, and we therefore conclude that some microbial species have greater potential to cause a biofilm-based infection, whereas others can be only passive members of the biofilm community.
Linkenhoker, Jan R; Burkholder, Tanya H; Linton, CG Garry; Walden, April; Abusakran-Monday, Kim A; Rosero, Ana P; Foltz, Charmaine J
2010-01-01
The goal of this study was to identify an injectable anesthetic protocol that provides sedation sufficient for peripheral vascular catheterization, intubation, and transport while minimizing cardiovascular changes in Yorkshire and Yucatan pigs with and without cardiovascular injury and intervention (CI). Phase 1 examined the safety and efficacy of acepromazine–ketamine, diazepam–ketamine, midazolam–ketamine, and medetomidine–ketamine in 5 healthy Yorkshire pigs. For each drug combination, we obtained multiple measurements of heart rate, blood pressure, respiratory rate, temperature, sedation score, ability to catheterize and intubate, and recovery score. Phase 2 evaluated and refined the dose of the most effective Phase 1 anesthetic combination (midazolam–ketamine) in healthy and CI Yorkshire pigs (n = 53 trials). Phase 3 mirrored Phase 2 but tested midazolam–ketamine in healthy and CI Yucatan pigs (n = 34 trials). Midazolam (0.5 mg/kg)–ketamine (25 to 27 mg/kg) was the most effective anesthetic combination in healthy Yorkshire pigs, but this dose was less effective in healthy Yucatan pigs and CI Yorkshire and Yucatan pigs. Midazolam–ketamine resulted in tachycardia and apnea more frequently in CI pigs than healthy pigs. This combination also caused vomiting in one CI Yucatan pig. Overall, midazolam–ketamine provided safe and effective sedation for catheterization and intubation of both healthy and CI pigs. This study suggests Yucatan pigs may require a higher dose midazolam–ketamine to achieve the same level of sedation as that in Yorkshire pigs. Although anesthetic complication rates were higher in CI pigs, our results indicate that midazolam–ketamine can be safely used for sedation of both pig breeds with and without CI. PMID:20587167
Invasive strategy for treatment of myocardial infarction.
Höfling, B; von Pölnitz, A
1990-01-01
The classical approach to the treatment of acute myocardial infarction (MI) has been one of stabilization and complication management. In an effort to optimize treatment, the initiation of the cardiac care unit and the use of antiarrhythmic therapy have succeeded in lowering the mortality rate substantially. More modern concepts are aimed at limiting infarct size and preserving myocardial function. These aims can be achieved medically using intravenous (i.v.) thrombolysis or invasively either with intracoronary (i.c.) thrombolysis, percutaneous transluminal coronary angioplasty (PTCA), or bypass surgery. Although i.c. thrombolysis is more effective than the i.v. route, the necessity for acute coronary catheterization makes it incompatible and difficult for routine use, and thus is usually reserved for cases in which i.v. lysis has failed. Intravenous thrombolysis is becoming the standard approach to MI, and the remaining questions are those of which drug and dosage are optimal and how to approach the patient after thrombolysis. In this regard, we favor a symptom-guided approach, as shown by the TIMI-IIA and European cooperative studies. In patients with ongoing ischemia postlysis, heart catheterization is indicated and a decision regarding PTCA or surgery is then made, depending on anatomy. In patients remaining stable after acute lysis, a predischarge stress may help in selecting patients requiring catheterization. As an alternative invasive approach to acute MI, PTCA may be the quickest and most effective method to recanalize a vessel, but, again, logistical problems make it incompatible in the acute setting. The same is true for bypass surgery, and although extensive improvements have been made in intraoperative myocardial preservation so that a 2% mortality is achievable, it is reserved for patients with extensive ischemia and anatomy unsuitable for PTCA (extensive multivessel or left main disease).
Raharjo, Robert Adrianto
2016-06-01
The aim of this study was to describe the diagnosis and treatment patterns of male lower urinary tract symptoms (LUTS) suggestive of benign prostatic hyperplasia (BPH) and evaluate their appropriateness in an area without an urologist and with limited resources, such as the area covered by Murjani General Hospital, Sampit, Indonesia. This descriptive study used data collected from medical records of patients who were diagnosed with LUTS suggestive of BPH in Murjani General Hospital between September 2013 and August 2015. There were 89 patients. Their mean age was 64.5 years. The most common chief complaint was inability to void (59.6%), followed by frequency (10.1%). Diagnostic evaluations such as symptom scoring (1.1%), frequency-volume chart (0%), digital rectal examination (3.4%), urinalysis (5.6%), and prostate-specific antigen (0%) were used rarely or never, while renal function assessment (37.1%) and imaging of the prostate (68.5%) and upper urinary tract (65.2%) were used more often. Overall, the treatment that was administered most often was indwelling catheterization (25.8%); only 19.1% visited a urologist following a referral by the physician, although 41.6% were referred to a urologist. There were 40.4% of patients with an indication for surgery, mostly in the form of recurrent or refractory urinary retention (83.3%). In this group of patients, only 38.9% received appropriate treatment in the form of open prostatectomy by a general surgeon (16.7%) or were referred to a urologist (22.2%), while 50% of them were managed with chronic indwelling catheterization. All patients received substandard diagnostic evaluations, with a pattern of preference toward imaging studies over more basic examinations for LUTS-BPH. The high frequency of indwelling catheterization in overall and inappropriate treatment in the group of patients with an indication for surgery showed that patients received suboptimal treatment. Improvements in various aspects are required to optimize the management of LUTS suggestive of BPH in Murjani General Hospital.
Renal angioplasty and stenting: is it still indicated after ASTRAL and STAR studies?
Henry, M; Benjelloun, A; Henry, I; Polydorou, A; Hugel, M
2010-10-01
A renal artery stenosis (RAS) is common among patients with atherosclerosis, up to a third of patients undergoing cardiac catheterization. Fibromuscular dysplasia is the next cause of RAS, commonly found in young women. Atherosclerosis RAS generally progresses overtime and is often associated with loss of renal mass and worsening renal function (RF). Percutaneous renal artery stent placement is the preferred method of revascularization for hemodynamically significant RAS according to ACC and AHA guidelines. Several randomized trials have shown the superiority of endovascular procedures to medical therapy alone. However, two studies ASTRAL and STAR studies were recently published and did not find any difference between renal stenting and medical therapy. But these studies have a lot of limitations and flaws as we will discuss (poor indications, poor results, numerous complications, failures, poor technique, inexperienced operators, ecc.). Despite these questionable studies, renal stenting keeps indications in patients with: uncontrolled hypertension; ischemic nephropathy; cardiac disturbance syndrome (e.g. "flash" pulmonary edema, uncontrolled heart failure or uncontrolled angina pectoris); solitary kidney. To improve the clinical response rates, a better selection of the patients and lesions is mandatory with: good non-invasive or invasive imaging; physiologic lesion assessment using transluminal pressure gradients; measurements of biomarkers (e.g., BNP); fractional flow reserve study. A problem remains after renal angioplasty stenting, the deterioration of the RF in 20-30% of the patients. Atheroembolism seems to play an important role and is probably the main cause of this R.F deterioration. The use of protection devices alone or in combination with IIb IIa inhibitors has been proposed and seems promising as shown in different recent reports. Renal angioplasty and stenting is still indicated but we need: a better patient and lesion selection; improvements in techniques and maybe the use of protection devices to reduce the risk of RF deterioration after renal stenting.
ERIC Educational Resources Information Center
Ma, Irene W. Y.; Zalunardo, Nadia; Pachev, George; Beran, Tanya; Brown, Melanie; Hatala, Rose; McLaughlin, Kevin
2012-01-01
The use of checklists is recommended for the assessment of competency in central venous catheterization (CVC) insertion. To explore the use of a global rating scale in the assessment of CVC skills, this study seeks to compare its use with two checklists, within the context of a formative examination using simulation. Video-recorded performances of…
Human Adaptation to the Tibetan Plateau
1991-08-12
exercise for only 30 min on arrival. design was to make measurements during high altitude Femoral arterial and venous catheterization . After the...studied after right heart catheterization . The Tibetans had remarkably low pulmonary artery pressures. Values averaged 14 mmHg, similar to the sea...their longer duration of Lhasa residences, may reflect favorable adaptations in a population with a long history of living at high altitude
ERIC Educational Resources Information Center
Su, Chung-Ho
2017-01-01
The advancement of mobile game-based learning has encouraged many related studies, which has enabled students to learn more and faster. To enhance the clinical path of cardiac catheterization learning, this paper has developed a mobile 3D-CCGBLS (3D Cardiac Catheterization Game-Based Learning System) with a learning assessment for cardiac…
Zhang, C; Zhu, Y; Li, Q Q; Gu, H
2018-06-02
Objective: To investigate the risk factors, clinical features, treatments, and prevention of pulmonary hypertensive crisis (PHC) in children with idiopathic pulmonary arterial hypertension (IPAH) undergoing cardiac catheterization. Methods: This retrospective study included 67 children who were diagnosed with IPAH and underwent cardiac catheterization between April 2009 and June 2017 in Beijing Anzhen Hospital. The medical histories, clinical manifestations, treatments, and outcomes were characterized. Statistical analyses were performed using t test, χ(2) test and a multiple Logistic regression analysis. Results: During cardiac catheterization, five children developed PHC who presented with markedly elevated pulmonary artery pressure and central venous pressure, decline in systemic arterial pressure and oxygen saturation. Heart rate decreased in 4 cases and increased in the remaining one. After the treatments including cardiopulmonary resuscitation, pulmonary vasodilator therapy, improving cardiac output and blood pressure, and correction of acidosis, 4 of the 5 cases recovered, while 1 died of severe right heart failure with irreversible PHC 3 days after operation. Potential PHC was considered in 7 other patients, whose pulmonary artery pressure increased and exceeded systemic arterial pressure, oxygen saturation decreased, and central venous pressure and vital signs were relatively stable. Univariate analysis showed that the risk factors of PHC in children with IPAH undergoing cardiac catheterization were younger age ( t= 3.160, P= 0.004), low weight ( t= 4.004, P< 0.001), general anesthesia (χ(2)=4.970, P= 0.026), history of syncope (χ(2)=4.948, P= 0.026), and WHO cardiac functional class Ⅲ or Ⅳ (χ(2)=19.013, P< 0.001). Multivariate Logistic regression analysis revealed that worse WHO cardiac functional class ( Wald =13.128, P< 0.001, OR= 15.076, 95% CI : 3.475-65.418) was the independent risk factor of PHC. Conclusions: PHC is a severe and extremely dangerous complication in children with IPAH during cardiac catheterization. WHO cardiac functional class may be associated with PHC. Integrated treatment is required for these patients. Reducing risk factors, early identification, and active treatment may help to prevent the occurrence and progression of PHC.
Camkiran Firat, Aynur; Zeyneloglu, Pinar; Ozkan, Murat; Pirat, Arash
2016-09-01
To compare internal jugular vein and subclavian vein access for central venous catheterization in terms of success rate and complications. A 1:1 randomized controlled trial. Baskent University Medical Center. Pediatric patients scheduled for cardiac surgery. Two hundred and eighty children undergoing central venous catheterization were randomly allocated to the internal jugular vein or subclavian vein group during a period of 18 months. The primary outcome was the first-attempt success rate of central venous catheterization through either approach. The secondary outcomes were the rates of infectious and mechanical complications. The central venous catheterization success rate at the first attempt was not significantly different between the subclavian vein (69%) and internal jugular vein (64%) groups (p = 0.448). However, the overall success rate was significantly higher through the subclavian vein (91%) than the internal jugular vein (82%) (p = 0.037). The overall frequency of mechanical complications was not significantly different between the internal jugular vein (25%) and subclavian vein (31%) (p = 0.456). However, the rate of arterial puncture was significantly higher with internal jugular vein (8% vs 2%; p = 0.03) and that of catheter malposition was significantly higher with subclavian vein (17% vs 1%; p < 0.001). The rates per 1,000 catheter days for both positive catheter-tip cultures (26.1% vs 3.6%; p < 0.001) and central-line bloodstream infection (6.9 vs 0; p < 0.001) were significantly higher with internal jugular vein. There were no significant differences between the groups in the length of ICU and hospital stays or in-hospital mortality rates (p > 0.05 for all). Central venous catheterization through the internal jugular vein and subclavian vein was not significantly different in terms of success at the first attempt. Although the types of mechanical complications were different, the overall rate was similar between internal jugular vein and subclavian vein access. The risk of infectious complications was significantly higher with internal jugular vein access.
Morita, Tomoya; Nakamura, Kensuke; Osuga, Tatsuyuki; Yokoyama, Nozomu; Morishita, Keitaro; Sasaki, Noboru; Ohta, Hiroshi; Takiguchi, Mitsuyoshi
2017-07-01
The assessment of hemodynamic change by echocardiography is clinically useful in patients with pulmonary hypertension. Recently, mild elevation of the mean pulmonary arterial pressure (PAP) has been shown to be associated with increased mortality. However, changes in the echocardiographic indices of right ventricular (RV) function are still unknown. The objective of this study was to validate the relationship between echocardiographic indices of RV function and right heart catheterization variables under a mild RV pressure overload condition. Echocardiography and right heart catheterization were performed in dog models of mild RV pressure overload induced by thromboxane A 2 analog (U46619) (n=7). The mean PAP was mildly increased (19.3±1.1 mm Hg), and the cardiac index was decreased. Most echocardiographic indices of RV function were significantly impaired even under a mild RV pressure overload condition. Multivariate analysis revealed that the RV free wall longitudinal strain (RVLS), standard deviation of the time-to-peak longitudinal strain of RV six segments (RV-SD) by speckle-tracking echocardiography, and Tei index were independent echocardiographic predictors of the mean PAP (free wall RVLS, β=-0.60, P<.001; RV-SD, β=0.40, P=.011), pulmonary vascular resistance (free wall RVLS, β=-0.39, P=.020; RV-SD, β=0.47, P=.0086; Tei index, β=0.34, P=.047), and cardiac index (Tei index, β=-0.65, P<.001). Free wall RVLS, RV-SD, and Tei index are useful for assessing the hemodynamic change under a mild RV pressure overload condition. © 2017, Wiley Periodicals, Inc.
SU-E-P-10: Imaging in the Cardiac Catheterization Lab - Technologies and Clinical Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fetterly, K
2014-06-01
Purpose: Diagnosis and treatment of cardiovascular disease in the cardiac catheterization laboratory is often aided by a multitude of imaging technologies. The purpose of this work is to highlight the contributions to patient care offered by the various imaging systems used during cardiovascular interventional procedures. Methods: Imaging technologies used in the cardiac catheterization lab were characterized by their fundamental technology and by the clinical applications for which they are used. Whether the modality is external to the patient, intravascular, or intracavity was specified. Specific clinical procedures for which multiple modalities are routinely used will be highlighted. Results: X-ray imaging modalitiesmore » include fluoroscopy/angiography and angiography CT. Ultrasound imaging is performed with external, trans-esophageal echocardiography (TEE), and intravascular (IVUS) transducers. Intravascular infrared optical coherence tomography (IVOCT) is used to assess vessel endothelium. Relatively large (>0.5 mm) anatomical structures are imaged with x-ray and ultrasound. IVUS and IVOCT provide high resolution images of vessel walls. Cardiac CT and MRI images are used to plan complex cardiovascular interventions. Advanced applications are used to spatially and temporally merge images from different technologies. Diagnosis and treatment of coronary artery disease frequently utilizes angiography and intra-vascular imaging, and treatment of complex structural heart conditions routinely includes use of multiple imaging modalities. Conclusion: There are several imaging modalities which are routinely used in the cardiac catheterization laboratory to diagnose and treat both coronary artery and structural heart disease. Multiple modalities are frequently used to enhance the quality and safety of procedures. The cardiac catheterization laboratory includes many opportunities for medical physicists to contribute substantially toward advancing patient care.« less
Fan, Yao; Gong, Xun; Wang, Nan; Mu, Ketao; Feng, Ling; Qiao, Fuyuan; Chen, Suhua; Zeng, Wanjiang; Liu, Haiyi; Wu, Yuanyuan; Zhou, Qiong; Tian, Yuan; Li, Qiang; Yang, Meitao; Li, Fanfan; He, Mengzhou; Beejadhursing, Rajluxmee; Deng, Dongrui
2017-01-01
Abstract We studied the efficacy of prophylactic internal iliac artery balloon catheterization for managing severe hemorrhage caused by pernicious placenta previa. This prospective observational study was conducted in Tongji Hospital, Wuhan, China. One hundred sixty-three women past 32-week's gestation with placenta previa–accreta were recruited and managed. Women in the balloon group accepted prophylactic internal iliac artery balloon catheterization before scheduled caesarean delivery and controls had a conventional caesarean delivery. Intraoperative hemorrhage, transfusion volume, radiation dose, exposure time, complications, and neonatal outcomes were discussed. Significant differences were detected in estimated blood loss (1236.0 mL vs 1694.0 mL, P = .01), calculated blood loss (CBL) (813.8 mL vs 1395.0 mL, P < .001), CBL of placenta located anteriorly (650.5 mL vs 1196.0 mL, P = .03), and anterioposteriorly (928.3 mL vs 1680.0 mL, P = .02). Prophylactic balloon catheterization could reduce intraoperative red blood cell transfusion (728.0 mL vs 1205.0 mL, P = .01) and lessen usage of perioperative hemostatic methods. The incidence of hysterectomy was lower in balloon group. Mean radiation dose was 29.2 mGy and mean exposure time was 92.2 seconds. Neonatal outcomes and follow-up data did not have significant difference. Prophylactic internal iliac artery balloon catheterization is an effective method for managing severe hemorrhage caused by placenta previa–accreta as it reduced intraoperative blood loss, lessened perioperative hemostatic measures and intraoperative red cell transfusions, and reduce hysterectomies. PMID:29137011
LaRovere, Kerri L; Kapur, Kush; McElhinney, Doff B; Razumovsky, Alexander; Kussman, Barry D
2017-07-01
Cerebral emboli are one potential cause of acute brain injury in children with congenital heart disease (CHD) undergoing cardiac catheterization. In this pilot study using transcranial Doppler (TCD) ultrasonography, we sought to evaluate the incidence, burden, and circumstances of cerebral high-intensity transient signals (HITS), presumably representing emboli, during pediatric cardiac catheterization. Emboli monitoring of the right middle cerebral artery was performed in five children. HITS, counted offline, were defined as unidirectional signals associated with audible "chirp" and sinusoidal correlation. HITS were grouped as single, >10 HITS ("cluster"), or HITS "with curtain effect" per 3-5 cardiac cycles. Cerebral blood flow velocity (CBFV) and pulsatility index (PI) were recorded after anesthetic induction (baseline). Total HITS in the cohort was 1,697 (790 single HITS, 606 HITS within clusters, and 301 HITS within curtains). HITS in clusters and curtains comprised 53% (907/1,697) of total HITS, and occurred in 44 clusters/curtains. Events associated with clusters/curtains included left ventricular angiography (39%; 17/44), right ventricular angiography (16%; 7/44), device placement (16%; 7/44), heparin bolus (9%; 4/44), pulmonary artery angiography (9%; 4/44), venous access (5%; 2/44), right atrial angiography (2%; 1/44), arterial access (2%; 1/44), and hemodynamic measurements (2%; 1/44). No patient had clinically detectable neurologic injury. HITS are common during pediatric cardiac catheterization, and associated with procedural factors. Whether curtains/clusters are worse than single, repetitive HITS is unknown. Larger studies are needed to determine whether HITS are a marker of risk of neurologic injury from emboli during pediatric cardiac catheterization. Copyright © 2017 by the American Society of Neuroimaging.
Gould, Richard; McFadden, Sonyia L; Horn, Simon; Prise, Kevin M; Doyle, Philip; Hughes, Ciara M
2016-01-01
Paediatric cardiac catheterizations may result in the administration of substantial amounts of iodinated contrast media and ionizing radiation. The aim of this work was to investigate the effect of iodinated contrast media in combination with in vitro and in vivo X-ray radiation on lymphocyte DNA. Six concentrations of iodine (15, 17.5, 30, 35, 45, and 52.5 mg of iodine per mL blood) represented volumes of iodinated contrast media used in the clinical setting. Blood obtained from healthy volunteers was mixed with iodinated contrast media and exposed to radiation doses commonly used in paediatric cardiac catheterizations (0 mGy, 70 mGy, 140 mGy, 250 mGy and 450 mGy). Control samples contained no iodine. For in vivo experimentation, pre and post blood samples were collected from children undergoing cardiac catheterization, receiving iodine concentrations of up to 51 mg of iodine per mL blood and radiation doses of up to 400 mGy. Fluorescence microscopy was performed to assess γH2AX-foci induction, which corresponded to the number of DNA double-strand breaks. The presence of iodine in vitro resulted in significant increases of DNA double-strand breaks beyond that induced by radiation for ≥ 17.5 mg/mL iodine to blood. The in vivo effects of contrast media on children undergoing cardiac catheterization resulted in a 19% increase in DNA double-strand breaks in children receiving an average concentration of 19 mg/mL iodine to blood. A larger investigation is required to provide further information of the potential benefit of lowering the amount of iodinated contrast media received during X-ray radiation investigations. Copyright © 2015 John Wiley & Sons, Ltd.
Fabreau, Gabriel E; Leung, Alexander A; Southern, Danielle A; James, Matthew T; Knudtson, Merrill L; Ghali, William A; Ayanian, John Z
2016-02-23
Metropolitan versus nonmetropolitan status and area median income may independently affect care for and outcomes of acute coronary syndromes. We sought to determine whether location of care modifies the association among area income, receipt of cardiac catheterization, and mortality following an acute coronary syndrome in a universal health care system. We studied a cohort of 14 012 acute coronary syndrome patients admitted to cardiology services between April 18, 2004, and December 31, 2011, in southern Alberta, Canada. We used multivariable logistic regression to determine the odds of cardiac catheterization within 1 day and 7 days of admission and the odds of 30-day and 1-year mortality according to area median household income quintile for patients presenting at metropolitan and nonmetropolitan hospitals. In models adjusting for area income, patients who presented at nonmetropolitan facilities had lower adjusted odds of receiving cardiac catheterization within 1 day of admission (odds ratio 0.22, 95% CI 0.11-0.46, P<0.001). Among nonmetropolitan patients, when examined by socioeconomic status, each incremental decrease in income quintile was associated with 10% lower adjusted odds of receiving cardiac catheterization within 7 days (P<0.001) and 24% higher adjusted odds of 30-day mortality (P=0.008) but no significant difference for 1-year mortality (P=0.12). There were no differences in adjusted mortality among metropolitan patients. Within a universal health care system, the association among area income and receipt of cardiac catheterization and 30-day mortality differed depending on the location of initial medical care for acute coronary syndromes. Care protocols are required to improve access to care and outcomes in patients from low-income nonmetropolitan communities. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Urine Cultures in Hospitalized Geriatric Patients Presenting With Fever.
Shimoni, Zvi; Avdiaev, Ruslan; Froom, Paul
2017-01-01
Urine cultures are commonly ordered in geriatric patients presenting with fever in the emergency department, but it is unclear if indiscriminate urine culture testing is warranted. We selected 708 consecutive geriatric patients with a chief complaint of fever to determine the clinical usage (changes in antibiotic therapy according to culture results) and the costs of culturing the urine that included the need for catheterization to obtain a sample for culture and complications from catheterization. We divided the patients into those with and without an extraurinary tract source for fever on admission. Urine cultures were performed in 74.9% (233/312) of the patients with a source for the fever outside the urinary tract and required urinary catheterization to obtain a sample in 36.8% (95/233) of those patients. Cultures were positive for bacteria 29.6% of the time (69/233), but did not result in the change of antibiotic treatment in any of the patients. Urine cultures were performed in 92.6% (326/352) of the patients without an extraurinary tract source for the fever, required catheterization in 49.7% (162/326) of the patients and 58.3% (190/326) of the cultures were positive for bacteria. Urine culture sensitivities changed antibiotic therapy in 24.2% (46/190) of the patients. There were no patients in either group with complications from urinary catheterization, but indwelling catheter rates increased inappropriately in both the groups. We conclude that urine culture testing is unnecessary in hospitalized geriatric patients who on admission have an extraurinary tract source for their fever, but it has clinical usage when the source for the fever on admission is unclear. Copyright © 2017 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Young Hwan; Pavcnik, Dusan, E-mail: pavcnikd@ohsu.edu; Kakizawa, Hideyaki
The purpose of this study was to evaluate the angiographic and histopathologic changes in the superficial femoral artery (SFA) in heparinized sheep shortly after catheterization with an 8-Fr sheath and manual compression hemostasis either with standard manual compression (SMC) or with the use of a procoagulant chitosan-based HemCon Bandage. The evaluation was done in 38 SFAs of 19 heparinized (100 mg/kg) sheep. After a 5-min catheterization with an 8-Fr sheath, a 5-min compression was applied. Follow-up angiograms to evaluate hemostasis were done immediately after release of compression and then at 2.5-min intervals until no extravasation was present. Compression was reappliedmore » between angiograms. Final angiograms were performed approximately 30 min after hemostasis and after 3 min of passive flexion and extension of sheep hind limbs. Sheep were then euthanized and SFA specimens with surrounding tissues excised for histopathologic evaluation. Both types of compression caused similar changes in the catheterized SFAs. Follow-up angiograms showed mild arterial narrowing in 14 SFAs and intraluminal clots in 9 SFAs. Histology revealed periarterial hematoma in all 38 specimens. Intraluminal thrombi consisting predominantly of platelets and fibrin were present in 32 SFAs. Their size varied from superficial elevations (8 arteries) to medium-sized, 1- to 2-mm, polypoid protrusions (15 arteries) to large polypoid clots, 3-4 mm long (9 arteries). In six SFAs, the arterial access sites were not included in the obtained specimens. In conclusion, hemostasis with manual compression is achieved in the acute phase by formation of a predominantly platelet-fibrin thrombus occluding the arterial wall access site and often extending significantly into the arterial lumen. The healing process of arterial access sites should be explored several days after catheterization.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jelev, L., E-mail: ljelev@abv.bg; Surchev, L.
2008-09-15
In routine clinical practice the variations of the radial artery are the main reason for technical failure during transradial catheterization. If these variations are well documented, however, they do not represent a problem in the transradial approach. Therefore, we report here a rare case of the radial artery which is very strange but potentially valuable for the clinical practice: it arises at a right angle from the brachial artery and passes behind the biceps brachii tendon. Based on our findings and on an extensive literature review, we propose for the first time a clinically oriented classification of the variations ofmore » the radial artery. This classification is related to the catheterization success at the usual access site of the radial artery at the wrist.« less
Andrade, Vera Lúcia Fonseca; Fernandes, Filipa Alexandra Veludo
2016-01-01
to describe strategies used by health professionals on the implementation of the Centers for Disease Control and Prevention guidelines for the prevention of urinary infection related to catheterism. systematic review on literature based on data from CINAHL(r), Nursing & Allied Health Collection, Cochrane Plus Collection, MedicLatina, MEDLINE(r), Academic Search Complete, ACS - American Chemical Society, Health Reference Center Academic, Nursing Reference Center, ScienceDirect Journals and Wiley Online Library. A sample of 13 articles was selected. studies have highlighted the decrease of urinary tract infection related to catheterism through reminder systems to decrease of people submitted to urinary catheterism, audits about nursing professionals practice and bundles expansion. the present review systemizes the knowledge of used strategies by health professionals on introduction to international recommendations, describing a rate decrease of such infection in clinical practice.
Coolman, B R; Marretta, S M; Kakoma, I; Wallig, M A; Coolman, S L; Paul, A J
1998-12-01
The purpose of this study was to determine the effects of a one-minute chlorhexidine gluconate skin preparation protocol prior to cephalic vein catheterization. Twenty-three healthy beagle dogs had one leg aseptically prepared and the opposite leg served as a control. Twenty-six- and 77-hour time groups were studied. Chlorhexidine-treated legs had significantly lower cutaneous bacterial counts than the control legs prior to catheter insertion and prior to catheter withdrawal for both time groups. Control legs developed significantly more dermatitis than the treated legs after 77 h. A one-minute preparation with 4% chlorhexidine gluconate was an effective method for sustained reduction of cutaneous bacterial counts at peripheral intravenous catheter insertion points in dogs. Increased cutaneous bacterial counts were associated with significantly more microscopic dermatitis in untreated legs after 77 h of catheterization.
Department of Clinical Investigation Annual Progress Report: Fiscal Year 1989
1989-01-01
Between Plasma Oxygen Permeability 10 and Atherosclerotic Coronary Artery Disease as Determined by Cardiac Catheterization C89-03 A Double-Blind, Parallel...Local Anesthetic Administration During Cardiac Catheterization C89-05 Intravenous Sotalol for the Termination of P3 Paroxysmal Supraventricular... History and Treatment of Patients with Non- Invasive Intraductal Adenocarcinoma H85-09 (**8H-85-I) Phase III Study of Subtotal Lymphoid Irradiation or
Craft, Christopher; Feldon, David F; Brown, Eric A
2014-05-01
Simulation-based learning is a common educational tool in health care training and frequently involves instructional designs based on Experiential Learning Theory (ELT). However, little research explores the effectiveness and efficiency of different instructional design methodologies appropriate for simulations. The aim of this study was to compare 2 instructional design models, ELT and Guided Experiential Learning (GEL), to determine which is more effective for training the central venous catheterization procedure. Using a quasi-experimental randomized block design, nurse anesthetists completed training under 1 of the 2 instructional design models. Performance was assessed using a checklist of central venous catheterization performance, pass rates, and critical action errors. Participants in the GEL condition performed significantly better than those in the ELT condition on the overall checklist score after controlling for individual practice time (F[1, 29] = 4.021, P = .027, Cohen's d = .71), had higher pass rates (P = .006, Cohen's d = 1.15), and had lower rates of failure due to critical action errors (P = .038, Cohen's d = .81). The GEL model of instructional design is significantly more effective than ELT for simulation-based learning of the central venous catheterization procedure, yielding large differences in effect size. Copyright © 2014 Elsevier Inc. All rights reserved.
Gulino, Ferdinando Antonio; Guardo, F Di; Zambrotta, E; Di Gregorio, L M; Miranda, Andrea; Capriglione, Stella; Palumbo, M A
2018-05-18
We studied the efficacy of using pre-cesarean delivery (CD) temporary occlusion of internal iliac arteries with balloon catheters in case of placenta previa-accreta in terms of maternal and neonatal outcomes and to test accuracy of ultrasound (US) and magnetic resonance imaging (MRI) for prenatal diagnosis. From March 2014 to January 2018, women with an US and/or MRI diagnosis of placenta previa-accreta and a planned delivery were enrolled and divided into two groups: balloon catheterization group (women treated with preoperative catheters and CD) and control group (women candidates to elective CD). 37 patients were enrolled: 16 in balloon catheterization group and 21 in control group. Significant differences were detected in estimated blood loss. Prophylactic balloon catheterization could reduce intraoperative red blood cell transfusion. The incidence of hysterectomy was lower in balloon group. No statistical difference was found for neonatal outcomes. Both US and MRI have showed to be useful and complementary to diagnose placenta previa-accreta. Temporal, perioperative, and prophylactic positioning of balloon vascular catheters is an effective method for managing severe hemorrhage caused by placenta previa-accreta as it reduced intraoperative blood loss, lessened perioperative hemostatic measures and intraoperative red cell transfusions, and reduced hysterectomies.
Kotoda, Atsushi; Akimoto, Tetsu; Kato, Maki; Kanazawa, Hidenori; Nakata, Manabu; Sugase, Taro; Ogura, Manabu; Ito, Chiharu; Sugimoto, Hideharu; Muto, Shigeaki; Kusano, Eiji
2011-01-01
It is widely assumed that central venous stenosis (CVS) is most commonly associated with previous central venous catheterization among the chronic hemodialysis (HD) patients. We evaluated the validity of this assumption in this retrospective study. The clinical records from 2,856 consecutive HD patients with vascular access failure during a 5-year period were reviewed, and a total of 26 patients with symptomatic CVS were identified. Combined with radiological findings, their clinical characteristics were examined. Only seven patients had a history of internal jugular dialysis catheterization. Diagnostic multidetector row computed tomography angiography showed that 7 of the 19 patients with no history of catheterization had left innominate vein stenosis due to extrinsic compression between the sternum and arch vessels. These patients had a shorter period from the time of creation of the vascular access to the initial referral (9.2 ± 7.6 months) than the rest of the patients (35.5 ± 18.6 months, p = 0.0017). Our findings suggest that cases without a history of central venous catheterization may not be rare among the HD patients with symptomatic CVS. However, those still need to be confirm by larger prospective studies of overall chronic HD patients with symptomatic CVS.
Fjordbakk, Cathrine T; Haga, Henning A
2011-06-01
To assess the efficacy of a commercially available topical vapocoolant spray in reducing responses to arthrocentesis of the middle carpal (MC) and metacarpophalangeal (MCP) joints and jugular vein catheterization in unsedated horses. 8 healthy research horses. Arthrocentesis of both MC and MCP joints and bilateral jugular vein catheterization were performed in each horse. Immediately prior to skin penetration, 1 randomly selected MC joint, MCP joint, and jugular vein were sprayed with a vapocoolant liquid (intervention product), and the contralateral MC joint, MCP joint, and jugular vein were sprayed with water (placebo). An observer blinded to the type of spray treatment used evaluated the horses' responses to needle or catheter placement procedures by use of a 6-point categorical scale and a 100-mm visual analog scale. Responses evaluated via the visual analog scale were significantly reduced after application of the intervention product, compared with responses after application of the placebo, for the MC and MCP joints; no difference in responses to jugular vein catheterization was detected between the 2 treatments. Vapocoolant spray was safe and effective in reducing horses' responses to arthrocentesis. The use of such products prior to joint injections may reduce procedural nociception and pain anticipation in unsedated horses and may improve the safety of personnel performing such procedures.
Guimaraes, M; Uflacker, R; Schonholz, C; Hannegan, C; Selby, B
2008-06-01
Although rare, misplacement of central venous catheters in supra-aortic arteries is potentially fatal. Five patients had safe catheters removal using percutaneous closure devices. Three patients were coagulopathic, 3 under intensive care and 1 in immediate postoperative limb amputation. Patients were treated successfully, with immediate hemostasis and without complications in a mean follow-up of 12.5 months. Although the number of patients is small, the closure devices proved to be safe. This is a minimally invasive alternative technique in the management of large bore catheters removed from non-compressible puncture sites such as subclavian and brachiocephalic arteries.
Ferreira, Marcelo; Ferreira, Diego; Cunha, Rodrigo; Bicalho, Guilherme; Rodrigues, Eduardo
2018-06-01
To demonstrate different techniques and device modifications that can expand the anatomic suitability of the off-the-shelf multibranched t-Branch for treatment of thoracoabdominal aortic aneurysm. The t-Branch device is not customized for specific patient anatomy, and the most frequent limitations to its use are an inadequate sealing zone and renal artery anatomy. Experience with this device has prompted the development of several techniques that can be employed to maximize the suitability of this stent-graft. Advice is offered on modification of the device to minimize the risk of paraplegia or better match patient anatomy. Maneuvers are explained to ease delivery through tortuous anatomy or existing stent-grafts, catheterize visceral target vessels, select a bridging stent, reduce ischemia time in the limbs, and alter the configuration of the branches. Employing adjunctive maneuvers can increase the anatomic suitability of the t-Branch; in our experience, these techniques have increased the applicability to more than 80% of all elective and urgent thoracoabdominal aortic aneurysm cases.
Development of Needle Insertion Manipulator for Central Venous Catheterization
NASA Astrophysics Data System (ADS)
Kobayashi, Yo; Hong, Jaesung; Hamano, Ryutaro; Hashizume, Makoto; Okada, Kaoru; Fujie, Masakatsu G.
Central venous catheterization is a procedure, which a doctor insert a catheter into the patient’s vein for transfusion. Since there are risks of bleeding from arterial puncture or pneumothorax from pleural puncture. Physicians are strictly required to make needle reach up into the vein and to stop the needle in the middle of vein. We proposed a robot system for assisting the venous puncture, which can relieve the difficulties in conventional procedure, and the risks of complication. This paper reports the design structuring and experimental results of needle insertion manipulator. First, we investigated the relationship between insertion force and angle into the vein. The results indicated that the judgment of perforation using the reaction force is possible in case where the needling angle is from 10 to 20 degree. The experiment to evaluate accuracy of the robot also revealed that it has beyond 0.5 mm accuracy. We also evaluated the positioning accuracy in the ultrasound images. The results displays that the accuracy is beyond 1.0 mm and it has enough for venous puncture. We also carried out the venous puncture experiment to the phantom and confirm our manipulator realized to make needle reach up into the vein.
France, Logan K; Vermillion, Meghan S; Garrett, Caroline M
2018-01-01
Blood pressure is a critical parameter for evaluating cardiovascular health, assessing effects of drugs and procedures, monitoring physiologic status during anesthesia, and making clinical decisions. The placement of an arterial catheter is the most direct and accurate method for measuring blood pressure; however, this approach is invasive and of limited use during brief sedated examinations. The objective of this study was to determine which method of indirect blood pressure monitoring was most accurate compared with measurement by direct arterial catheterization. In addition, we sought to determine the relative accuracy of each indirect method (compared with direct arterial measurement) at a given body location and to assess whether the accuracy of each indirect method was dependent on body location. We compared direct blood pressure measurements by means of catheterization of the saphenous artery with oscillometric and ultrasonic Doppler flow detection measurements at 3 body locations (forearm, distal leg, and tail base) in 16 anesthetized, male rhesus macaques. The results indicate that oscillometry at the forearm is the best indirect method and location for accurately and consistently measuring blood pressure in healthy male rhesus macaques.
Frohwein, S; Ververis, J J; Marshall, J J
1995-04-01
Dissection of the subclavian artery during routine cardiac catheterization while obtaining cannulation to the left internal mammary artery is an unusual complication and to our knowledge has never been reported. Conservative management of this vascular injury can avoid the sequelae of high-risk surgical repairs made difficult by a complex operative exposure. We describe a case in which dissection of the left subclavian artery was treated conservatively with an excellent outcome.
Pasteurella aerogenes as an Asymptomatic Bacteriuria Agent.
Alaygut, Demet; Engin, Aynur
2018-02-01
'Asymptomatic bacteriuria' (ASB) is isolation of a specified quantitative count of bacteria in an appropriately collected urine specimen obtained from a person without symptoms or signs referable to urinary infection. Catheterized specimens are less likely to be contaminated compared with voided specimens; therefore, positive cultures of catheterized specimens are more likely to reflect true bladder bacteriuria even with low colony counts. The common pathogens for ASB are Escherichia coli, Klebsiella and Streptococcus spp. Pasteurella spp. was not previously reported as an ASB agent. ASB is important for pregnant women, children, individuals with obstructive uropathy, chronic renal failure and neutropenia, before the urologic procedures and after renal transplantation. Treatment of ASB is required for above situations. We report an 11-year-old-girl with neurogenic bladder who made clean intermittent catheterization and had Pasteurella aerogenes as an ASB agent. © The Author [2017]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
[Methods of resolution for haptic assistance during catheterization].
Kern, T A; Herrmann, J; Klages, S; Meiss, T; Werthschützky, R
2005-01-01
During catheterization navigation within the patient is mainly dependent on a live x-ray image on the screen. Although methods for 3D visualisation and remote navigation of the catheter are discussed and tested still precise positioning is merely the result of intense training and a high skill and level of training of the performing surgeon. This article refers to a system which can be considered as an add-on for existing procedures of catheterization. It compromises of a miniaturised force sensor located at the tip of guide-wires whose prototype is shown here. The measured forces will be presented to the surgeon amplified by an external actuator described in this article. As a result a haptic perception of the forces between the tip of the guide-wire and the vessels walls will be available and enable the surgeon to gain an impression which is comparable to palpation of living vessels from the inside
[Gastric band erosion: Alternative management].
Echaverry-Navarrete, Denis José; Maldonado-Vázquez, Angélica; Cortes-Romano, Pablo; Cabrera-Jardines, Ricardo; Mondragón-Pinzón, Erwin Eduardo; Castillo-González, Federico Armando
2015-01-01
Obesity is a public health problem, for which the prevalence has increased worldwide at an alarming rate, affecting 1.7 billion people in the world. To describe the technique employed in incomplete penetration of gastric band where endoscopic management and/or primary closure is not feasible. Laparoscopic removal of gastric band was performed in five patients with incomplete penetrance using Foley catheterization in the perforation site that could lead to the development of a gastro-cutaneous fistula. The cases presented include a leak that required surgical lavage with satisfactory outcome, and one patient developed stenosis 3 years after surgical management, which was resolved endoscopically. In all cases, the penetration site closed spontaneously. Gastric band erosion has been reported in 3.4% of cases. The reason for inserting a catheter is to create a controlled gastro-cutaneous fistula, allowing spontaneous closure. Various techniques have been described: the totally endoscopic, hybrid techniques (endoscopic/laparoscopic) and completely laparoscopic. A technique is described here that is useful and successful in cases where the above-described treatments are not viable. Copyright © 2015. Published by Masson Doyma México S.A.
Stukel, Thérèse A.; Fisher, Elliott S; Wennberg, David E.; Alter, David A.; Gottlieb, Daniel J.; Vermeulen, Marian J.
2007-01-01
Context Comparisons of outcomes between patients treated and untreated in observational studies may be biased due to differences in patient prognosis between groups, often because of unobserved treatment selection biases. Objective To compare 4 analytic methods for removing the effects of selection bias in observational studies: multivariable model risk adjustment, propensity score risk adjustment, propensity-based matching, and instrumental variable analysis. Design, Setting, and Patients A national cohort of 122 124 patients who were elderly (aged 65–84 years), receiving Medicare, and hospitalized with acute myocardial infarction (AMI) in 1994–1995, and who were eligible for cardiac catheterization. Baseline chart reviews were taken from the Cooperative Cardiovascular Project and linked to Medicare health administrative data to provide a rich set of prognostic variables. Patients were followed up for 7 years through December 31, 2001, to assess the association between long-term survival and cardiac catheterization within 30 days of hospital admission. Main Outcome Measure Risk-adjusted relative mortality rate using each of the analytic methods. Results Patients who received cardiac catheterization (n=73 238) were younger and had lower AMI severity than those who did not. After adjustment for prognostic factors by using standard statistical risk-adjustment methods, cardiac catheterization was associated with a 50% relative decrease in mortality (for multivariable model risk adjustment: adjusted relative risk [RR], 0.51; 95% confidence interval [CI], 0.50–0.52; for propensity score risk adjustment: adjusted RR, 0.54; 95% CI, 0.53–0.55; and for propensity-based matching: adjusted RR, 0.54; 95% CI, 0.52–0.56). Using regional catheterization rate as an instrument, instrumental variable analysis showed a 16% relative decrease in mortality (adjusted RR, 0.84; 95% CI, 0.79–0.90). The survival benefits of routine invasive care from randomized clinical trials are between 8% and 21 %. Conclusions Estimates of the observational association of cardiac catheterization with long-term AMI mortality are highly sensitive to analytic method. All standard risk-adjustment methods have the same limitations regarding removal of unmeasured treatment selection biases. Compared with standard modeling, instrumental variable analysis may produce less biased estimates of treatment effects, but is more suited to answering policy questions than specific clinical questions. PMID:17227979
Intermittent Self-catheterization in Older Adults: Predictors of Success for Technique Learning
2018-01-01
Purpose The main goal of this retrospective study is to explore the predictors of success in learning clean intermittent self-catheterization (CISC) in patients over 65 years of age. The secondary goal is to assess whether in this population, the risk of failure to perform CISC is greater, compared with patients under 65 with similar pathologies. Methods All patients older than 65 consulting between January 2011 and January 2016 for learning CISC were included. A control population younger than 65 matching with sex, body mass index, and pathology was selected. Results One hundred sixty-nine of the 202 patients (83.7%) over 65 succeeded in learning CISC. Obesity (P<0.05), low pencil and paper test (PP test) (P<0.01) and low functional independence measure (FIM) (P<0.01) scores were risk factors of failure. No significant differences were found with sex or pathology. In multivariate analysis, low PP test perineum access (odds ratio [95% confidence interval], 2.30 [1.32–4.42]), low FIM motor (1.04 [1.01–1.08]), and FIM cognition (1.18 [1.03–1.37]) scores were independent factors of learning failure. Compared to control group, age over 65 was not predictive of failure (P=0.15). Conclusions Our study shows that success in learning CISC does not depend on age but on difficulties in mobility, access to perineum and probably cognitive disorders. PMID:29609423
Zhao, Ruiyi; Chen, Chunfang; Jin, Jingfen; Sharma, Komal; Jiang, Nan; Shentu, Yingqin; Wang, Xingang
2016-06-01
The use of peripherally inserted central catheters (PICCs) provides important central venous accesses for clinical treatments, tests and monitoring. Compared with the traditional methods, intracardiac electrocardiogram (ECG)-guided method has the potential to guide more accurate tip positioning of PICCs. This study aimed to clinically evaluate the effectiveness of an intracardiac ECG to guide the tip positioning by monitoring characteristic P-wave changes. In this study, eligible patients enrolled September 2011 to May 2012 according to the inclusion and exclusion criteria received the catheterization monitored by intracardiac ECG. Then chest radiography was performed to check the catheter position. The results revealed that, with 117 eligible patients, all bar one patient who died (n = 116) completed the study, including 60 males and 56 females aged 51.2 ± 15.1 years. Most (n = 113, > 97%) had characteristic P-wave changes. The intracardiac ECG-guided positioning procedure achieved correct placement for 112 patients (96.56%), demonstrating 99.12% sensitivity and 100% specificity. In conclusion, the intracardiac ECG can be a promising technique to guide tip positioning of PICCs. However, since the sample size in this study is limited, more experience and further study during clinical practice are needed to demonstrate achievement of optimal catheterization outcomes. © 2015 John Wiley & Sons Australia, Ltd.
Aorto-right atrial fistula after Bentall repair.
Howard, Charles E; Velasco, Carlos E; Roullard, Christina P; Rafael, Aldo
2017-07-01
We describe a man with the Marfan syndrome and a prior ascending aortic aneurysm resection who presented with knee pain and concern of endocarditis. Transesophageal echocardiogram showed no vegetations, and computed tomography angiogram of the heart showed a possible pseudoaneurysm. Cardiac catheterization and aortogram revealed the diagnosis of an aorto-right atrial fistula, which was then operatively repaired. This case highlights the role that cardiac catheterization with aortogram can play in the detection of aorto-atrial fistula.
Decompression from Saturation Using Oxygen: Its Effect on DCS and RNA in Large Swine
2010-01-01
mask. The external jugular vein was catheter- ized with a 14-Ga., 30-cm single lumen catheter ( Central Venous Catheterization Set; Arrow... venous catheterization for sequential blood sampling from the pig. J Invest Surg 1991; 4:103-7. 3. Behnke AR. The isobaric (oxygen window) principle of...pressures may lead to toxicity that involves the pulmonary system and/ or the central nervous system (CNS). There is evidence that 100% oxygen in
NASA Astrophysics Data System (ADS)
Keshavarz-Motamed, Zahra
2015-11-01
Coarctation of the aorta (COA) is a congenital heart disease corresponding to a narrowing in the aorta. Cardiac catheterization is considered to be the reference standard for definitive evaluation of COA severity, based on the peak-to-peak trans-coarctation pressure gradient (PtoP TCPG) and instantaneous systolic value of trans-COA pressure gradient (TCPG). However, invasive cardiac catheterization may carry high risks given that undergoing multiple follow-up cardiac catheterizations in patients with COA is common. The objective of this study is to present an analytical description of the COA that estimates PtoP TCPG and TCPG without a need for high risk invasive data collection. Coupled Navier-Stokes and elastic deformation equations were solved analytically to estimate TCPG and PtoP TCPG. The results were validated against data measured in vitro (e.g., 90% COA: TCPG: root mean squared error (RMSE) = 3.93 mmHg; PtoP TCPG: RMSE = 7.9 mmHg). Moreover, the estimated PtoP TCPG resulted from the suggested analytical description was validated using clinical data in twenty patients with COA (maximum RMSE: 8.3 mmHg). Very good correlation and concordance were found between TCPG and PtoP TCPG obtained from the analytical formulation and in vitro and in vivo data. The suggested methodology can be considered as an alternative to cardiac catheterization and can help preventing its risks.
Lee, Seung-Eun; Park, Yong-Sook; Kim, Young-Baeg
2010-01-01
Objective The purpose of this study is to identify the relationship between asymptomatic urinary tract infection (aUTI) and postoperative spine infection. Methods A retrospective review was done in 355 women more than 65 years old who had undergone laminectomy and/or discectomy, and spinal fusion, between January 2004 and December 2008. Previously postulated risk factors (i.e., instrumentation, diabetes, prior corticosteroid therapy, previous spinal surgery, and smoking) were investigated. Furthermore, we added aUTI that was not previously considered. Results Among 355 patients, 42 met the criteria for aUTI (Bacteriuria ≥ 105 CFU/mL and no associated symptoms). A postoperative spine infection was evident in 15 of 355 patients. Of the previously described risk factors, multi-levels (p < 0.05), instrumentation (p < 0.05) and diabetes (p < 0.05) were proven risk factors, whereas aUTI (p > 0.05) was not statistically significant. However, aUTI with Foley catheterization was statistically significant when Foley catheterization was added as a variable to the all existing risk factors. Conclusion aUTI is not rare in elderly women admitted to the hospital for lumbar spine surgery. The results of this study suggest that aUTI with Foley catheterization may be considered a risk factor for postoperative spine infection in elderly women. Therefore, we would consider treating aUTI before operating on elderly women who will need Foley catheterization. PMID:20461166
Matte, Roselene; Hilário, Thamires de Souza; Reich, Rejane; Aliti, Graziella Badin; Rabelo-Silva, Eneida Rejane
2016-01-01
Abstract Objective: to compare the incidence of vascular complications in patients undergoing transfemoral cardiac catheterization with a 6F introducer sheath followed by 3-hour versus 5-hour rest. Methods: randomized clinical trial. Subjects in the intervention group (IG) ambulated 3 hours after sheath removal, versus 5 hours in the control group (CG). All patients remained in the catheterization laboratory for 5 hours and were assessed hourly, and were contacted 24, 48, and 72 h after hospital discharge. Results: the sample comprised 367 patients in the IG and 363 in the GC. During cath lab stay, hematoma was the most common complication in both groups, occurring in 12 (3%) IG and 13 (4%) CG subjects (P=0.87). Bleeding occurred in 4 (1%) IG and 6 (2%) CG subjects (P=0.51), and vasovagal reaction in 5 (1.4%) IG and 4 (1.1%) CG subjects (P=0.75). At 24-h, 48-h, and 72-h bruising was the most commonly reported complication in both groups. None of the comparisons revealed any significant between-group differences. Conclusion: the results of this trial show that reducing bed rest time to 3 hours after elective cardiac catheterization is safe and does not increase complications as compared with a 5-hour rest. ClinicalTrials.gov Identifier: NCT-01740856 PMID:27463113
Raucci, Frank J; Seckeler, Michael D; Saunders, Christine; Gangemi, James J; Peeler, Benjamin B; Jayakumar, K Anitha
2013-01-01
Neo-aortic arch obstruction (NAAO) is a common complication following the Norwood/Sano procedure (NP) for hypoplastic left heart syndrome (HLHS) and is associated with increased morbidity and mortality. However, there is currently no objective method for predicting which patients will develop NAAO. This study was designed to test the hypothesis that hemodynamic changes from development of NAAO after NP in patients with HLHS will lead to changes in myocardial dynamics that could be detected before clinical symptoms develop with strain analysis using velocity vector imaging. Patients with HLHS who had at least one cardiac catheterization after NP were identified retrospectively. Strain analysis was performed on all echocardiograms preceding the first catheterization and any subsequent catheterization performed for intervention on NAAO. Twelve patients developed NAAO and 30 patients never developed NAAO. Right ventricular strain was worse in the group that developed NAAO (-6.2 vs. -8.6 %, p = 0.040) at a median of 59 days prior to diagnosis of NAAO. Those patients that developed NAAO following NP were significantly younger at the time of first catheterization than those that did not develop NAAO (92 ± 50 vs. 140 ± 36 days, p = 0.001). This study demonstrates that right ventricular GLS is abnormal in HLHS patients following NP and worsening right ventricular strain may be predictive of the future development of NAAO.
Reverse waffle cone technique in management of stent dislodgement into intracranial aneurysms.
Luo, Chao-Bao; Lai, Yen-Jun; Teng, Michael Mu-Huo; Chang, Feng-Chi; Lin, Chung-Jung; Guo, Wan-Yuo
2013-09-01
Stent-assisted coil embolization (SACE) is a common method to manage intracranial wide-neck aneurysm. Using this technique, a stent must be successfully deployed into the parent artery to cross the aneurysm neck. We describe the reverse waffle cone technique in management of intra-procedural stent dislodgement during SACE of internal carotid artery (ICA) wide-neck aneurysms. Two patients with unruptured wide-neck ICA aneurysms underwent SACE. Intra-procedural forward stent migration occurred during catheterization with proximal stent dislodgement and migration into the aneurysm sac. Navigation of a second stent to bridge the aneurysm neck failed in one patient because the second stent was impeded by the dislodged stent. Using the reverse waffle cone technique, a microcatheter was navigated into the aneurysm sacs. Coils were safely detached into each aneurysm sac without any device assistance. The two wide-neck aneurysms were successfully treated with preservation of flow to the internal carotid arteries. The complication of intra-procedural distal stent migration and dislodgement, with proximal stent prolapse into an aneurysm sac, may not result in a failure to coil the aneurysm. The reverse waffle cone technique provides an effective treatment in the management of this complication. Copyright © 2013 Elsevier Ltd. All rights reserved.
Yokoyama, Shinya; Nagato, Hisao; Yoshida, Yuichi; Nagasaka, Shigeo; Kaneda, Kozo; Nishiwaki, Noboru
2016-01-16
Although repair of a supravalvular aortic stenosis (SVAS) can be performed with low mortality rates, surgery for the complex form of SVAS continues to be associated with a high incidence of residual stenosis. The patient was referred to our hospital at 1 month of age and was diagnosed with aortic valve stenosis (AS) by using echocardiography. Cardiac catheterization revealed moderate AS, and subsequent left ventriculography revealed discrete stenosis of the sino-tubular junction and a narrowed proximal ascending aorta. We performed a reconstructive operation for such heart defects involving novel three-sinus and ascending aorta enlargement without aortic root transection in a 6-month-old boy. Our novel three-sinus enlargement technique is suitable for treating each type of SVAS and is a useful method for a baby particularly less than 10 kg without disturbing the growth of the ascending aorta.
Min, Bo Mi
2013-01-01
Continuous epidural analgesia has been used for decades to treat acute herpes zoster pain and to prevent postherpetic neuralgia. However, many technical problems can arise during chronic treatment with epidural medications. These complications include catheter dislodgement, infection, injection pain, leakage, and occlusion. Epidural catheter placement utilizing subcutaneous injection port implantation has gained widespread acceptance as a method to overcome such complications. The technique reduces the risk of infection, the most feared complication, compared to the use of a percutaneous epidural catheter. Herein, we present 2 cases in which the continuous thoracic epidural administration of opioids and local anesthetics through an implantable subcutaneous injection port for over 2 months successfully treated zoster-associated pain without any technique- or medication-related complications in patients with risk factors for epidural abscess. PMID:24363852
Boyer, L; Badère, J M; Dupont le Priol, P; Viallet, J F; Ribal, J P; Glanddier, G
1991-10-01
Screening of cerebrovascular disease by transbranchial arch injection. One hundred and seventy five patients underwent non selective intra arterial digital subtraction angiography using a transbranchial approach. Unilateral failure occurred in eight patients, but contralateral approach was then possible. Transient cerebral ischaemia affected one patient. Seven locoregional complications occurred, five of them underwent among the seventy three first procedures. Experience of the examining radiologist, duration of procedure and diameter of the catheter (4 or 5 F) are essential safety factors. Three false-negative and one false-positive in carotid bifurcations appears with surgical results reviews. This safe and efficient technique is often sufficient for a therapeutic decision, especially for surgery, but, in a few cases, additional selective injections can be necessary. Possible in out patients, this approach is chosen when femoral artery catheterization is impossible, or before reconstructive aorto-ilio-femoral surgery, to decrease septic risk.
Lin, C Huie; Hegde, Sanjeet; Marshall, Audrey C; Porras, Diego; Gauvreau, Kimberlee; Balzer, David T; Beekman, Robert H; Torres, Alejandro; Vincent, Julie A; Moore, John W; Holzer, Ralf; Armsby, Laurie; Bergersen, Lisa
2014-01-01
Continued advancements in congenital cardiac catheterization and interventions have resulted in increased patient and procedural complexity. Anticipation of life-threatening events and required rescue measures is a critical component to preprocedural preparation. We sought to determine the incidence and nature of life-threatening adverse events in congenital and pediatric cardiac catheterization, risk factors, and resources necessary to anticipate and manage events. Data from 8905 cases performed at the 8 participating institutions of the Congenital Cardiac Catheterization Project on Outcomes were captured between 2007 and 2010 [median 1,095/site (range 133-3,802)]. The incidence of all life-threatening events was 2.1 % [95 % confidence interval (CI) 1.8-2.4 %], whereas mortality was 0.28 % (95 % CI 0.18-0.41 %). Fifty-seven life-threatening events required cardiopulmonary resuscitation, whereas 9 % required extracorporeal membrane oxygenation. Use of a risk adjustment model showed that age <1 year [odd ratio (OR) 1.9, 95 % CI 1.4-2.7, p < 0.001], hemodynamic vulnerability (OR 1.6, 95 % CI 1.1-2.3, p < 0.01), and procedure risk (category 3: OR 2.3, 95 % CI 1.3-4.1; category 4: OR 4.2, 95 % CI 2.4-7.4) were predictors of life-threatening events. Using this model, standardized life-threatening event ratios were calculated, thus showing that one institution had a life-threatening event rate greater than expected. Congenital cardiac catheterization and intervention can be performed safely with a low rate of life-threatening events and mortality; preprocedural evaluation of risk may optimize preparation of emergency rescue and bailout procedures. Risk predictors (age < 1, hemodynamic vulnerability, and procedure risk category) can enhance preprocedural patient risk stratification and planning.
Video networking of cardiac catheterization laboratories.
Tobis, J; Aharonian, V; Mansukhani, P; Kasaoka, S; Jhandyala, R; Son, R; Browning, R; Youngblood, L; Thompson, M
1999-02-01
The purpose of this study was to assess the feasibility and accuracy of a video telecommunication network to transmit coronary images to provide on-line interaction between personnel in a cardiac catheterization laboratory and a remote core laboratory. A telecommunication system was installed in the cardiac catheterization laboratory at Kaiser Hospital, Los Angeles, and the core laboratory at the University of California, Irvine, approximately 40 miles away. Cineangiograms, live fluoroscopy, intravascular ultrasound studies and images of the catheterization laboratory were transmitted in real time over a dedicated T1 line at 768 kilobytes/second at 15 frames/second. These cases were performed during a clinical study of angiographic guidance versus intravascular ultrasound (IVUS) guidance of stent deployment. During the cases the core laboratory performed quantitative analysis of the angiograms and ultrasound images. Selected images were then annotated and transmitted back to the catheterization laboratory to facilitate discussion during the procedure. A successful communication hookup was obtained in 39 (98%) of 40 cases. Measurements of angiographic parameters were very close between the original cinefilm and the transmitted images. Quantitative analysis of the ultrasound images showed no significant difference in any of the diameter or cross-sectional area measurements between the original ultrasound tape and the transmitted images. The telecommunication link during the interventional procedures had a significant impact in 23 (58%) of 40 cases affecting the area to be treated, the size of the inflation balloon, recognition of stent underdeployment, or the existence of disease in other areas that was not noted on the original studies. Current video telecommunication systems provide high-quality images on-line with accurate representation of cineangiograms and intravascular ultrasound images. This system had a significant impact on 58% of the cases in this small clinical trial. Telecommunication networks between hospitals and a central core laboratory may facilitate physician training and improve technical skills and judgement during interventional procedures. This project has implications for how multicenter clinical trials could be operated through telecommunication networks to ensure conformity with the protocol.
Karimi-Sari, Hamidreza; Faraji, Mehrdad; Mohazzab Torabi, Saman; Asjodi, Gholamreza
2014-12-01
Central venous catheterization (CVC) is an important procedure in emergency departments (EDs). Despite existence of ultrasonography (US) devices in every ED, CVC is done using anatomical landmarks in many EDs in Iran. This study aimed to compare the traditional landmark method vs. US-guided method of CVC placement in terms of complications and success rate. In this randomized controlled trial, patients who were candidate for internal jugular vein catheterization, and referred to Baqiyatallah Hospital ED were randomly allocated into US-guided CVC and anatomical landmarks guided CVC groups. Central vein access time, number of attempts, success rate, and complications in each group were evaluated. Mann-Whitney U, chi-square and Fisher exact tests along with Pearson and Spearman correlation coefficients were used to analyze the data. Out of 100 patients, 56 were male and 44 were female. No significant differences were found between the US-guided and traditional landmark methods of CVC insertion in terms of age, gender, BMI, and site of catheter insertion. The mean access time was significantly lower in the US-guided group (37.12 ± 17.33 s vs. 63.42 ± 35.19 s, P < 0.001). The mean number of attempts was also significantly lower in the US-guided group (1.12 ± 0.3 vs. 1.58 ± 0.64 times, P < 0.001). Eighty-eight percent of patients in the US-guided group were catheterized in the first attempt, while 50% of patients in the traditional landmark group were catheterized in the second or more attempts (P < 0.001). The success rate was 100% in the US-guided group, while it was 88% in the landmark group (P = 0.013). Moreover, the rate of complications was significantly lower in the US-guided group (4% vs. 24%, P = 0.004). The US-guided method for CVC placement was superior to the traditional landmark method in terms of access time, number of attempts, success rate, and fewer complications.
Design and performance evaluation of a master controller for endovascular catheterization.
Guo, Jin; Guo, Shuxiang; Tamiya, Takashi; Hirata, Hideyuki; Ishihara, Hidenori
2016-01-01
It is difficult to manipulate a flexible catheter to target a position within a patient's complicated and delicate vessels. However, few researchers focused on the controller designs with much consideration of the natural catheter manipulation skills obtained from manual catheterization. Also, the existing catheter motion measurement methods probably lead to the difficulties in designing the force feedback device. Additionally, the commercially available systems are too expensive which makes them cost prohibitive to most hospitals. This paper presents a simple and cost-effective master controller for endovascular catheterization that can allow the interventionalists to apply the conventional pull, push and twist of the catheter used in current practice. A catheter-sensing unit (used to measure the motion of the catheter) and a force feedback unit (used to provide a sense of resistance force) are both presented. A camera was used to allow a contactless measurement avoiding additional friction, and the force feedback in the axial direction was provided by the magnetic force generated between the permanent magnets and the powered coil. Performance evaluation of the controller was evaluated by first conducting comparison experiments to quantify the accuracy of the catheter-sensing unit, and then conducting several experiments to evaluate the force feedback unit. From the experimental results, the minimum and the maximum errors of translational displacement were 0.003 mm (0.01 %) and 0.425 mm (1.06 %), respectively. The average error was 0.113 mm (0.28 %). In terms of rotational angles, the minimum and the maximum errors were 0.39°(0.33 %) and 7.2°(6 %), respectively. The average error was 3.61°(3.01 %). The force resolution was approximately 25 mN and a maximum current of 3A generated an approximately 1.5 N force. Based on analysis of requirements and state-of-the-art computer-assisted and robot-assisted training systems for endovascular catheterization, a new master controller with force feedback interface was proposed to maintain the natural endovascular catheterization skills of the interventionalists.
Campbell-Washburn, Adrienne E; Rogers, Toby; Stine, Annette M; Khan, Jaffar M; Ramasawmy, Rajiv; Schenke, William H; McGuirt, Delaney R; Mazal, Jonathan R; Grant, Laurie P; Grant, Elena K; Herzka, Daniel A; Lederman, Robert J
2018-06-21
Cardiovascular magnetic resonance (CMR) fluoroscopy allows for simultaneous measurement of cardiac function, flow and chamber pressure during diagnostic heart catheterization. To date, commercial metallic guidewires were considered contraindicated during CMR fluoroscopy due to concerns over radiofrequency (RF)-induced heating. The inability to use metallic guidewires hampers catheter navigation in patients with challenging anatomy. Here we use low specific absorption rate (SAR) imaging from gradient echo spiral acquisitions and a commercial nitinol guidewire for CMR fluoroscopy right heart catheterization in patients. The low-SAR imaging protocol used a reduced flip angle gradient echo acquisition (10° vs 45°) and a longer repetition time (TR) spiral readout (10 ms vs 2.98 ms). Temperature was measured in vitro in the ASTM 2182 gel phantom and post-mortem animal experiments to ensure freedom from heating with the selected guidewire (150 cm × 0.035″ angled-tip nitinol Terumo Glidewire). Seven patients underwent CMR fluoroscopy catheterization. Time to enter each chamber (superior vena cava, main pulmonary artery, and each branch pulmonary artery) was recorded and device visibility and confidence in catheter and guidewire position were scored on a Likert-type scale. Negligible heating (< 0.07°C) was observed under all in vitro conditions using this guidewire and imaging approach. In patients, chamber entry was successful in 100% of attempts with a guidewire compared to 94% without a guidewire, with failures to reach the branch pulmonary arteries. Time-to-enter each chamber was similar (p=NS) for the two approaches. The guidewire imparted useful catheter shaft conspicuity and enabled interactive modification of catheter shaft stiffness, however, the guidewire tip visibility was poor. Under specific conditions, trained operators can apply low-SAR imaging and using a specific fully-insulated metallic nitinol guidewire (150 cm × 0.035" Terumo Glidewire) to augment clinical CMR fluoroscopy right heart catheterization. Clinicaltrials.gov NCT03152773 , registered May 15, 2017.
Angiographic follow-up of infants and children undergoing percutaneous carotid artery interventions.
Ligon, R Allen; Kim, Dennis W; Vincent, Robert N; Bauser-Heaton, Holly D; Ooi, Yinn K; Petit, Christopher J
2018-01-23
The purpose of this study was to review the outcomes following the percutaneous carotid arterial (PCA) approach in infants and children with congenital heart disease. PCA access is becoming more commonly adopted following reports demonstrating it is a safe alternative to surgical carotid cutdown and even the femoral arterial route. However, follow-up outcomes after PCA remain unreported. We reviewed all cases with PCA access and follow-up catheterizations which included carotid artery (CA) angiography between May 2012 until December 2016. We examined for evidence of CA stenosis at follow-up angiography and assessed any other CA complications associated with vascular access. There were 61 PCA catheterizations performed in 55 unique patients. Follow-up CA imaging with angiography was available in 43 patients (78%, 43/55). There was no vessel stenosis nor lumen irregularity in 28 (65%) patients. In 15 cases (35%), there was a mild degree of irregularity or narrowing by angiography (median 4.1%, range 2.3%-12.5%). Nine patients underwent repeat PCA catheterizations. Seven of these had no visible vascular stenosis on follow-up angiographic imaging, including a patient who was accessed three separate times from the CA. No statistically significant risk factors for developing mild CA stenosis were identified. PCA access for pediatric interventional catheterization appears to be safe with a very low rate of mild stenosis, and very few complications. Follow-up outcomes in our series are excellent, with a CA patency rate of 100%, even after multiple procedures. Mild CA stenosis was not associated with patient size or sheath introducer caliber. While the acute results from percutaneous CA catheterization have proven safe in recent literature, longer-term outcomes remain unreported. At our institution, the outcomes following percutaneous carotid access are associated with an excellent patency rate of 100%, even after multiple procedures on the same vessel. A low incidence of mild vessel stenosis can be appreciated on follow-up angiography. © 2018 Wiley Periodicals, Inc.
Venous Access Ports: Indications, Implantation Technique, Follow-Up, and Complications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walser, Eric M., E-mail: walser.eric@mayo.edu
The subcutaneous venous access device (SVAD or 'port') is a critical component in the care of patients with chronic disease. The modern SVAD provides reliable access for blood withdrawal and medication administration with minimal disruption to a patient's lifestyle. Because of improved materials and catheter technology, today's ports are lighter and stronger and capable of high-pressure injections of contrast for cross-sectional imaging. The majority of SVAD placement occurs in interventional radiology departments due to their ability to provide this service at lower costs, lower, complication rates, and greater volumes. Port-insertion techniques vary depending on the operator, but all consist ofmore » catheter placement in the central venous circulation followed by subcutaneous pocket creation and port attachment to the catheter with fixation and closure of the pocket. Venous access challenges occasionally occur in patients with central vein occlusions, necessitating catheterization of collateral veins or port placement in alternate locations. Complications of SVADs include those associated with the procedure as well as short- (<30 days) and long-term problems. Procedural and early complications are quite rare due to the near-universal use of real-time ultrasound guidance for vein puncture, but they can include hematoma, catheter malposition, arrhythmias, and pneumothorax. Late problems include both thrombotic complications (native venous or port-catheter thrombosis) and infections (tunnel or pocket infections or catheter-associated bloodstream infections). Most guidelines suggest that 0.3 infections/1000 catheter days is an appropriate upper threshold for the insertion of SVADs.« less
Intrafascial nerve-sparing endoscopic extraperitoneal radical prostatectomy.
Stolzenburg, Jens-Uwe; Rabenalt, Robert; Do, Minh; Schwalenberg, Thilo; Winkler, Mathias; Dietel, Anja; Liatsikos, Evangelos
2008-05-01
Based on our recently published anatomic studies, we present the most recent refinement of the endoscopic extraperitoneal radical prostatectomy (EERPE), the intrafascial nerve-sparing EERPE (nsEERPE). As part of the intrafascial technique, the dissection plane is directly on the prostatic capsule, freeing the prostate laterally from its thin surrounding fascia that contains small vessels and nerves. The technique enables puboprostatic ligament preservation, leaving intact endopelvic fascia, periprostatic fascia, and neurovascular bundles. The operation was performed in 150 patients with indications for nerve-sparing procedure. The mean operative time was 131 min (range: 50-210 min) and the mean catheterization time was 5.9 d (range: 4-20 d). Twelve months postoperatively, 94.3% of the patients were continent (no need for pads), 4.6% had minimal stress incontinence, and one patient required >2 pads/d. At the 12-mo follow-up, the potency rates (erections sufficient for intercourse with or without the use of phosphodiesterase 5 [PDE5] inhibitors) of the patients who underwent bilateral intrafascial nsEERPE were 89.7% (age: 44-55 yr), 81.1% (age: 56-65 yr), and 61.9% (age: >65 yr). Positive surgical margins in pT2 and pT3 tumors were 4.5% and 29.4%, respectively. The intrafascial nsEERPE enables the dissection of the prostate with limited trauma to the surrounding fascias and the enclosed neurovascular bundles. We propose that the preserved neurovascular bundles with intrafascial nsEERPE are more viable. The results advocate this proposition.
McDonnell, Alicia; Downing, Tacy E; Zhu, Xiaowei; Ryan, Rachel; Rossano, Joseph W; Glatz, Andrew C
2014-11-01
Pediatric heart transplant recipients undergo a variety of radiologic tests with the attendant risk of exposure to ionizing radiation. We sought to quantify and describe the cumulative exposure to all forms of medical radiation during the first year after pediatric heart transplantation and identify factors associated with higher exposure. Pediatric patients who received a heart transplant between January 2009 and May 2012 with follow-up at our institution were retrospectively reviewed. Patients were included if they survived through 1 year and the first coronary angiography. All medical testing using ionizing radiation performed during follow-up was compiled, and exposures were converted to effective dose (mSv). Included were 31 patients who underwent heart transplantation at a median age of 13.6 years (range, 0.3-18.3 years). The median number of radiologic tests performed was 38 (range, 18-154), including 8 catheterizations (range, 2-12), and 28 X-ray images (range, 11-135). Median cumulative effective dose was 53.5 mSv (range, 10.6-153.5 mSv), of which 91% (range, 34%-98%) derived from catheterizations, 31% (range, 8%-89%) of the exposure occurred during the transplant admission, 59% (range, 11%-88%) during planned follow-up, and 3% (0%-56%) during unplanned follow-up. Older age at transplant was a risk factor for increased exposure (p = 0.006). When adjusted for age, a trend toward increased exposure was shown for congenital heart disease as the indication for transplant (p = 0.08), pre-sensitization (p = 0.12), and positive crossmatch (p = 0.09). Pediatric heart transplant patients are exposed to significant amounts of ionizing radiation during the first post-transplant year, most during scheduled catheterization. As survival improves, considering the long-term risks associated with these levels of exposure is important. Copyright © 2014 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Di Maria, Michael V; Burkett, Dale A; Younoszai, Adel K; Landeck, Bruce F; Mertens, Luc; Ivy, D Dunbar; Friedberg, Mark K; Hunter, Kendall S
2015-11-01
Right ventricular (RV) failure is a key determinant of mortality in children with pulmonary arterial hypertension (PAH). RV stroke work (RVSW) can be estimated as the product of RV systolic pressure and stroke volume. The authors have shown that RVSW predicts adverse outcomes in this population when derived from hemodynamic data; noninvasive assessment of RVSW may be advantageous but has not been assessed. There are few data validating noninvasive versus invasive measurements in children with PAH. The aim of this study was to compare echocardiographically derived RVSW with RVSW determined from hemodynamic data. This was a retrospective study, including subjects with idiopathic PAH and minor or repaired congenital heart disease. Forty-nine subjects were included, in whom cardiac catheterization and echocardiography were performed within 1 month. Fourteen additional patients were included in a separate cohort, in whom catheterization and echocardiography were performed simultaneously. Catheterization-derived RVSW was calculated as RV systolic pressure × (cardiac output/heart rate). Echocardiographically derived RVSW was calculated as 4 × (peak tricuspid regurgitant jet velocity)(2) × (pulmonary valve area × velocity-time integral). Statistics included the intraclass correlation coefficient and Bland-Altman analysis. Echocardiographically derived RVSW was linearly correlated with invasively derived RVSW (r = 0.74, P < .0001, intraclass correlation coefficient = 0.76). Bland-Altman analysis showed adequate agreement. Echocardiographically derived RV work was related to indexed pulmonary vascular resistance (r = 0.43, P = .002), tricuspid annular plane systolic excursion (r = 0.41, P = .004), and RV wall thickness (r = 0.62, P < .0001). The authors demonstrate that RV work, a potential novel index of RV function, can be estimated noninvasively and is related to pulmonary hemodynamics and other indices of RV performance. Copyright © 2015 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Goudeketting, Seline R; Heinen, Stefan G; van den Heuvel, Daniel A; van Strijen, Marco J; de Haan, Michiel W; Slump, Cornelis H; de Vries, Jean-Paul P
2018-02-01
The effect of the insertion of guidewires and catheters on fusion accuracy of the three-dimensional (3D) image fusion technique during iliac percutaneous transluminal angioplasty (PTA) procedures has not yet been investigated. Technical validation of the 3D fusion technique was evaluated in 11 patients with common and/or external iliac artery lesions. A preprocedural contrast-enhanced magnetic resonance angiogram (CE-MRA) was segmented and manually registered to a cone-beam computed tomography image created at the beginning of the procedure for each patient. The treating physician visually scored the fusion accuracy (i.e., accurate [<2 mm], mismatch [2-5 mm], or inaccurate [>5 mm]) of the entire vasculature of the overlay with respect to the digital subtraction angiography (DSA) directly after the first obtained DSA. Contours of the vasculature of the fusion images and DSAs were drawn after the procedure. The cranial-caudal, lateral-medial, and absolute displacement were calculated between the vessel centerlines. To determine the influence of the catheters, displacement of the catheterized iliac trajectories were compared with the noncatheterized trajectories. Electronic databases were systematically searched for available literature published between January 2010 till August 2017. The mean registration error for all iliac trajectories (N.=20) was small (4.0±2.5 mm). No significant difference in fusion displacement was observed between catheterized (N.=11) and noncatheterized (N.=9) iliac arteries. The systematic literature search yielded 2 manuscripts with a total of 22 patients. The methodological quality of these studies was poor (≤11 MINORS Score), mainly due to a lack of a control group. Accurate image fusion based on preprocedural CE-MRA is possible and could potentially be of help in iliac PTA procedures. The flexible guidewires and angiographic catheters, routinely used during endovascular procedures of iliac arteries, did not cause significant displacement that influenced the image fusion. Current literature on 3D image fusion in iliac PTA procedures is of limited methodological quality.
Causes of cine image quality deterioration in cardiac catheterization laboratories.
Levin, D C; Dunham, L R; Stueve, R
1983-10-01
Deterioration of cineangiographic image quality can result from malfunctions or technical errors at a number of points along the cine imaging chain: generator and automatic brightness control, x-ray tube, x-ray beam geometry, image intensifier, optics, cine camera, cine film, film processing, and cine projector. Such malfunctions or errors can result in loss of image contrast, loss of spatial resolution, improper control of film optical density (brightness), or some combination thereof. While the electronic and photographic technology involved is complex, physicians who perform cardiac catheterization should be conversant with the problems and what can be done to solve them. Catheterization laboratory personnel have control over a number of factors that directly affect image quality, including radiation dose rate per cine frame, kilovoltage or pulse width (depending on type of automatic brightness control), cine run time, selection of small or large focal spot, proper object-intensifier distance and beam collimation, aperture of the cine camera lens, selection of cine film, processing temperature, processing immersion time, and selection of developer.
Iliescu, Cezar; Grines, Cindy L; Herrmann, Joerg; Yang, Eric H; Cilingiroglu, Mehmet; Charitakis, Konstantinos; Hakeem, Abdul; Toutouzas, Konstantinos; Leesar, Massoud A; Marmagkiolis, Konstantinos
2016-04-01
In the United States alone, there are currently approximately 14.5 million cancer survivors, and this number is expected to increase to 20 million by 2020. Cancer therapies can cause significant injury to the vasculature, resulting in angina, acute coronary syndromes (ACS), stroke, critical limb ischemia, arrhythmias, and heart failure, independently from the direct myocardial or pericardial damage from the malignancy itself. Consequently, the need for invasive evaluation and management in the cardiac catheterization laboratory (CCL) for such patients has been increasing. In recognition of the need for a document on special considerations for cancer patients in the CCL, the Society for Cardiovascular Angiography and Interventions (SCAI) commissioned a consensus group to provide recommendations based on the published medical literature and on the expertise of operators with accumulated experience in the cardiac catheterization of cancer patients. © 2015 Wiley Periodicals, Inc.
Iliescu, Cezar A; Grines, Cindy L; Herrmann, Joerg; Yang, Eric H; Cilingiroglu, Mehmet; Charitakis, Konstantinos; Hakeem, Abdul; Toutouzas, Konstantinos P; Leesar, Massoud A; Marmagkiolis, Konstantinos
2016-04-01
In the United States alone, there are currently approximately 14.5 million cancer survivors, and this number is expected to increase to 20 million by 2020. Cancer therapies can cause significant injury to the vasculature, resulting in angina, acute coronary syndromes (ACS), stroke, critical limb ischemia, arrhythmias, and heart failure, independently from the direct myocardial or pericardial damage from the malignancy itself. Consequently, the need for invasive evaluation and management in the cardiac catheterization laboratory (CCL) for such patients has been increasing. In recognition of the need for a document on special considerations for cancer patients in the CCL, the Society for Cardiovascular Angiography and Interventions (SCAI) commissioned a consensus group to provide recommendations based on the published medical literature and on the expertise of operators with accumulated experience in the cardiac catheterization of cancer patients. © 2016 Wiley Periodicals, Inc.
Venous catheterization with ultrasound navigation
NASA Astrophysics Data System (ADS)
Kasatkin, A. A.; Urakov, A. L.; Nigmatullina, A. R.
2015-11-01
By ultrasound scanning it was determined that respiratory movements made by chest of healthy and sick person are accompanied by respiratory chest rise of internal jugular veins. During the exhalation of an individual diameter of his veins increases and during the breath it decreases down to the complete disappearing if their lumen. Change of the diameter of internal jugular veins in different phases can influence significantly the results of vein puncture and cauterization in patients. The purpose of this research is development of the method increasing the efficiency and safety of cannulation of internal jugular veins by the ultrasound visualization. We suggested the method of catheterization of internal jugular veins by the ultrasound navigation during the execution of which the puncture of venous wall by puncture needle and the following conduction of J-guide is carried out at the moment of patient's exhalation. This method decreases the risk of complications development during catheterization of internal jugular vein due to exclusion of perforating wound of vein and subjacent tissues and anatomical structures.
Herpes zoster-associated acute urinary retention: a case report.
Julia, Jimmy J; Cholhan, Hilary J
2007-01-01
An 87-year-old woman presents with a 4-week history of urinary incontinence during which she had been treated for disseminated herpes zoster virus (HZV). On physical exam painful vesicles involving the entire vulvar region with mainly right sacral distribution were found. A catheterized volume exceeded 600 ml of retained urine after the patient failed to void spontaneously. Multichannel voiding-pressure urodynamic studies revealed an acontractile neurogenic bladder with overflow incontinence. The patient was discharged on a conservative regimen with arrangement for visiting nurse services to perform intermittent self-catheterization twice daily. Urodynamic testing was repeated 10 weeks after initial symptoms. During voiding cystometry a biphasic increase in detrusor pressure of 15 cm H2O was observed with no increase in abdominal pressure. The patient emptied 400 ml with a postvoid residual of 300 ml. Recovery from HZV-associated bladder emptying dysfunction can be achieved usually through conservative management, including intermittent self-catheterization. Complete recovery time ranges from 4 to 10 weeks.
Venous catheterization with ultrasound navigation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kasatkin, A. A., E-mail: ant-kasatkin@yandex.ru; Nigmatullina, A. R.; Urakov, A. L., E-mail: ant-kasatkin@yandex.ru
By ultrasound scanning it was determined that respiratory movements made by chest of healthy and sick person are accompanied by respiratory chest rise of internal jugular veins. During the exhalation of an individual diameter of his veins increases and during the breath it decreases down to the complete disappearing if their lumen. Change of the diameter of internal jugular veins in different phases can influence significantly the results of vein puncture and cauterization in patients. The purpose of this research is development of the method increasing the efficiency and safety of cannulation of internal jugular veins by the ultrasound visualization.more » We suggested the method of catheterization of internal jugular veins by the ultrasound navigation during the execution of which the puncture of venous wall by puncture needle and the following conduction of J-guide is carried out at the moment of patient’s exhalation. This method decreases the risk of complications development during catheterization of internal jugular vein due to exclusion of perforating wound of vein and subjacent tissues and anatomical structures.« less
Yoo, Moon Sook; Yoo, Il Young; Lee, Hyejung
2010-07-01
An opportunity for a student to evaluate his or her own performance enhances self-awareness and promotes self-directed learning. Using three outcome measures of competency of procedure, communication skills, and learning motivation, the effects of self-evaluation using a video recording of the student's Foley catheterization was investigated in this study. The students in the experimental group (n = 20) evaluated their Foley catheterization performance by reviewing the video recordings of their own performance, whereas students in the control group (n = 20) received written evaluation guidelines only. The results showed that the students in the experimental group had better scores on competency (p < 0.001), communication skills (p < 0.001), and learning motivation (p = 0.018) than the control group at the post-test, which was conducted 8 weeks after the pretest. Self-awareness of one's own performance developed by reviewing a videotape appears to increase the competency of clinical skills in nursing students. Copyright 2010, SLACK Incorporated.
Charles Theodore Dotter: The Father of Intervention
Payne, Misty M.
2001-01-01
The 1st percutaneous transluminal angioplasty marked a new era in the treatment of peripheral atherosclerotic lesions. The early techniques used in peripheral percutaneous transluminal angioplasty form the basis for subsequent percutaneous intervention both in the peripheral and coronary arteries and are largely the contribution of Charles Dotter. Dotter was the 1st to describe flow-directed balloon catheterization, the double-lumen balloon catheter, the safety guidewire, percutaneous arterial stenting, and more. This practical genius dedicated his considerable energy to the belief that there is always a better way to treat disease. His personal contributions to clinical medicine, research, and teaching have saved millions of limbs and lives all over the world. PMID:11330737
Gaspar Hernández, Jorge; Eid-Lidt, Guering; Payró Ramírez, Gerardo; Ricalde Alcocer, Alejandro; Martínez Ríos, Marco A
2012-01-01
A patient with resistant hypertension successfully treated with sympathetic renal denervation (SRD) is reported. This novel therapy is based on the partial ablation of the renal nerves by applying radiofrequency to the luminal surface of the renal arteries using vascular catheterization techniques. This first case performed in Mexico has two particular features: (i) an electrophysiology ablation catheter was employed due to the unavailability of the system specifically designed for SDR, and (ii) under current denervation protocols, the anatomical complexity of the targeted renal arteries would have excluded our patient from this procedure and thus deprived her of the benefit provided.
Aldoss, Osamah; Patel, Sonali; Harris, Kyle; Divekar, Abhay
2015-06-01
The objective of the study is to compare radiation dose between the frontal and lateral planes in a biplane cardiac catheterization laboratory. Tube angulation progressively increases patient and operator radiation dose in single-plane cardiac catheterization laboratories. This retrospective study captured biplane radiation dose in a pediatric cardiac catheterization laboratory between April 2010 and January 2014. Raw and time-indexed fluoroscopic, cineangiographic and total (fluoroscopic + cineangiographic) air kerma (AK, mGy) and kerma area product (PKA, µGym(2)/Kg) for each plane were compared. Data for 716 patients were analyzed: 408 (56.98 %) were male, the median age was 4.86 years, and the median weight was 17.35 kg. Although median beam-on time (minutes) was 4.2 times greater in the frontal plane, there was no difference in raw median total PKA between the two planes. However, when indexed to beam-on time, the lateral plane had a higher median-indexed fluoroscopic (0.75 vs. 1.70), cineangiographic (16.03 vs. 24.92), and total (1.43 vs. 5.15) PKA (p < 0.0001). The median time-indexed total PKA in the lateral plane is 3.6 times the frontal plane. This is the first report showing that the lateral plane delivers a higher dose than the frontal plane per unit time. Operators should consciously reduce the lateral plane beam-on time and incorporate this practice in radiation reduction protocols.
Effect of web-based education on nursing students' urinary catheterization knowledge and skills.
Öztürk, Deniz; Dinç, Leyla
2014-05-01
Nursing is a practice-based discipline that requires the integration of theory and practice. Nurse educators must continuously revise educational curricula and incorporate information technology into the curriculum to provide students with the necessary knowledge and skills. The aim of this study was to assess the effect of web-based education on students' urinary catheterization knowledge and skills. A convenience sample of 111 first year nursing students enrolled at two universities in Ankara during the academic year of 2011-2012 participated in this quasi-experimental study. The experimental group (n=59) received a web-based and web-enhanced learning approach along with learning and practicing the required material twice as much as the control group, whereas the control group (n=52) received traditional classroom instruction. A knowledge test of 20 multiple-choice questions and a skills checklist were used to assess student performance. There was no difference between the experimental group and the control group in knowledge scores; however, students in the web-based group had higher scores for urinary catheterization skills. The highest scores in knowledge and skills were obtained by students who experienced web-based education as a supplement to tradition instruction. Web-based education had positive effects on the urinary catheterization skills of nursing students, and its positive effect increased for both knowledge and skills when it supplements classroom instruction. Based on these results, we suggest the use of web-based education as a supplement to traditional classroom instruction for nursing education. © 2013.
Initial experience with the Cardiva Boomerang vascular closure device in diagnostic catheterization.
Doyle, Brendan J; Godfrey, Michael J; Lennon, Ryan J; Ryan, James L; Bresnahan, John F; Rihal, Charanjit S; Ting, Henry H
2007-02-01
The authors studied the safety and efficacy of the Cardiva Boomerang vascular closure device in patients undergoing diagnostic cardiac catheterization. Conventional vascular closure devices (sutures, collagen plugs, or metal clips) have been associated with catastrophic complications including arterial occlusion and foreign body infections; furthermore, they cannot be utilized in patients with peripheral vascular disease or vascular access site in a vessel other than the common femoral artery. The Cardiva Boomerang device facilitates vascular hemostasis without leaving any foreign body behind at the access site, can be used in peripheral vascular disease, and can be used in vessels other than the common femoral artery A total of 96 patients undergoing transfemoral diagnostic cardiac catheterization were included in this study, including 25 (26%) patients with contraindications to conventional closure devices. Femoral angiography was performed prior to deployment of the Cardiva Boomerang closure device. Patients were ambulated at 1 hr after hemostasis was achieved. The device was successfully deployed and hemostasis achieved with the device alone in 95 (99%) patients. The device failed to deploy in 1 (1%) patient and required conversion to standard manual compression. Minor complications were observed in 5 (5%) patients. No patients experienced major complications including femoral hematoma > 4 cm, red blood cell transfusion, retroperitoneal bleed, arteriovenous fistula, pseudoaneurysm, infection, arterial occlusion, or vascular surgery. The Cardiva Boomerang device is safe and effective in patients undergoing diagnostic cardiac catheterization using the transfemoral approach, facilitating early ambulation with low rates of vascular complications. (c) 2006 Wiley-Liss, Inc.
Kilciler, Mete; Erdemir, Fikret; Demir, Erkan; Güven, Oğuz; Avci, Ali
2008-09-01
To assess whether Foley catheterization of the rectum after transrectal ultrasound (TRUS)-guided prostate biopsy decreases complication rates. Between June 2000 and September 2006, 275 consecutive patients were evaluated after undergoing TRUS-guided prostate biopsy. All procedures were performed on an outpatient basis. Patients were divided into two groups. In the first group (n = 134), a Foley catheter was inserted into the rectum and inflated to 50 cm(3) after TRUS-guided biopsy. In the second group (n = 141), catheterization was performed without balloon placement. Rectal bleeding, hematuria, hematospermia, infection, and acute urinary retention rates were compared between groups. The mean ages of the patients were 63.3 years +/- 5.6 and 62.1 years +/- 7.2 years in the Foley catheter group and control group, respectively (P = .112). Hematuria, hematospermia, infection, and rectal bleeding occurred in 31 (23.1%), 30 (22.4), nine (6.7%), and two patients (1.5%), respectively, in the Foley catheter group; and in 36 (25.5%), 36 (25.5%), 11 (7.8%), and 25 patients (17.7%), respectively, in the control group. The incidences of infection, hematuria, and hematospermia were not significantly different between groups (P > .05). In contrast, the rectal bleeding rate was significantly lower in the Foley catheter group (1.5%) than in the control group (17.7%; P = .001). Although it has no effect on other complications, TRUS-guided prostate biopsy with rectal Foley catheterization is a useful, practical method to decrease or prevent rectal bleeding.
[Surgical treatment of recurrent urethral strictures in males after unsuccessful operations].
Simon, V; Vacík, J; Michálek, J; Novák, V; Lopour, P; Spunda, M
2000-12-06
Subvesical obstructions of any origin represent a frequent and serious disorder occurring predominantly in males. Often it brings incontinence and/or erectility dysfunction, infection of urinary tract. Relapses of the acute pyelonephritis can turn into chronic tubulointersticial one and terminate in the renal insufficiency. To treat strictures, dilation, intermittent catheterization and recently stent introduction were used. Most suitable appears a stent from composite polymers. The aim of our work was to test properties of stents developed in the Institute of Macromolecular Chemistry ASCR. Stents from composite polymers, which are non-toxic, not-irritable can swell in body fluids and have mechanical properties similar to that of silicone rubber. Properties of the material are functionally graded and the casting or repoussé from the material can subsequently change its shape. Ten patients (males, aged 25 to 78 years) with long urethral strictures in its bulbocavernous part (50%) were treated with this method. Strictures were caused by pelvical fractures (4 times), prostate hypertrophy surgery (4 times), prolonged catheterizations (2 times). All patients were followed for 16 to 26 month and had no severities. Our results indicate that stent from composite polymers and silicone may have long-acting effects without irritation or crust formation and beneficially effected healing of the spongio-fibrous process.
Kuwamoto, Satoshi; Murai, Yuki; Endo, Yukari; Masago, Toshihiko; Kuroda, Naoto; Horie, Yasushi
2014-01-01
Renal carcinomas associated with Xp11.2 translocations/TFE3 gene fusions are rare subtypes of renal neoplasm that predominantly occur in younger individuals. There are very few reports describing the cytologic features of these tumors. A 27-year-old man presented with hematuria and was found to have a mass in the lower part of the right kidney. Cytology of catheterized urine obtained from the right renal pelvis showed clusters of cells with abundant clear or eosinophilic granular cytoplasm, large round nuclei and prominent nucleoli. Papillary clusters containing thin fibrous stroma were occasionally seen. Voided urine cytology showed similar cell clusters but degeneration made the features obscure. Nephroureterectomy revealed a renal tumor showing a mixed papillary and nested architecture. The diagnosis was confirmed by immunohistochemistry and fluorescence in situ hybridization. The present case indicates that the characteristic features of these tumor subtypes can be retained in urine cytology. Cytology may be enough to suspect these tumors as part of the differential diagnosis when the patient's age and imaging findings are taken into account and may facilitate further studies for a definitive diagnosis. © 2014 S. Karger AG, Basel.
Transcatheter intervention for the treatment of congenital cardiac defects.
Grifka, R G
1997-01-01
Cardiac catheterization has an illustrious history, originating in 1929 when Werner Forsmann, a surgical resident, performed a heart catheterization on himself. Transcatheter interventional procedures have been performed since the 1960s. The 1st intracardiac procedure to become standard therapy was a balloon atrial septostomy. Skeptics attacked this innovative procedure. However, the balloon septostomy procedure soon became the standard emergency procedure for certain congenital heart defects, and was the impetus for other investigators in the field of transcatheter intervention. We will discuss transcatheter treatment for congenital vascular stenoses and vascular occlusion. Images PMID:9456482
Use of the FLOTAC technique to diagnosing parasites of the urinary tract of dogs.
Lima, Victor Fernando Santana; Ramos, Rafael Antonio Nascimento; Lepold, Raphael; Cringoli, Giuseppe; Rinaldi, Laura; Faustino, Maria Aparecida da Glória; Alves, Leucio Câmara
2016-04-01
Among the nematodes that infect the urinary tract of dogs, the Dioctophyma renale and Capillaria plica are those more frequently reported. For a long time, sedimentation was the only method used to detect eggs of these parasites in urine. The aim of this study was to analyze urine samples (n = 54) of dogs, obtained by bladder catheterization or cystocentesis, by using a modified FLOTAC technique. Animals were divided into two groups, i.e., with (n = 20) and without (n = 34) suspicion of urinary disease. The overall positivity herein observed was 3.8 % (2/54), being all animals (10 %; 2/20) from the group with suspicion of urinary disease. In the first positive sample, a single egg of D. renale was detected, whereas in the second sample two trematode-like eggs were observed. This is the first short survey employed to detect eggs of parasites that inhabit the urinary tract of dogs using a modified FLOTAC technique; in addition, for the first time, eggs of D. renale have been detected using this tool.
Ilin, Alexey S; Teplov, Pavel V; Sakovich, Valeriy A; Ohye, Richard G
2016-01-01
We present a case of 12-month-old boy with congenitally corrected transposition of great arteries with L-looped ventricles and L-transposition of great arteries and ventricular septal defect. When admitted to the hospital, the patient had the appearance of congestive heart failure due to moderate to severe tricuspid valve regurgitation and right ventricle dysfunction. The pulmonary artery (PA) banding was required first because of low systolic pressure in the morphological left ventricle less than 70% confirmed by catheterization. Three months later, the patient appeared to be a good candidate for anatomical repair and a double switch procedure-Senning with arterial switch-was performed. The early postoperative period was relatively smooth and uneventful. Tricuspid valve insufficiency was resolved immediately after surgery. Mild systolic dysfunction of the left ventricle with mild mitral insufficiency was confirmed by the 2D strain method of echocardiography on the second day of the postoperative period and it improved over the next 21 days. Thirty days later after the procedure, the patient underwent catheterization of his superior vena cava tunnel because of the slightly increased blood flow velocity diagnosed by echocardiography. In 3 months after the surgery, the boy was asymptomatic and was doing well. The patient's functional status was I according to the NYHA classification. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
2014-01-01
Background Central venous catheters play an important role in patient care. Real-time ultrasound-guided subclavian central venous (SCV) cannulation may reduce the incidence of complications and the time between skin penetration and the aspiration of venous blood into the syringe. Ultrasonic diagnosis of catheter misplacement and pneumothorax related to central venous catheterization is rapid and accurate. It is unclear, however, whether ultrasound real-time guidance and examination can reduce procedure times and complication rates when compared with landmark guidance and radiographic examination for SCV catheterization. Methods/Design The Subclavian Central Venous Catheters Guidance and Examination by UltraSound (SUBGEUS) study is an investigator-initiated single center, randomized, controlled two-arm trial. Three hundred patients undergoing SCV catheter placement will be randomized to ultrasound real-time guidance and examination or landmark guidance and radiographic examination. The primary outcome is the time between the beginning of the procedure and control of the catheter. Secondary outcomes include the times required for the six components of the total procedure, the occurrence of complications (pneumothorax, hemothorax, or misplacement), failure of the technique and occurrence of central venous catheter infections. Discussion The SUBGEUS trial is the first randomized controlled study to investigate whether ultrasound real-time guidance and examination for SCV catheter placement reduces all procedure times and the rate of complications. Trial registration ClinicalTrials.gov Identifier: NCT01888094 PMID:24885789
Teng, Jingfei; Zhang, Dongxu; Li, Yao; Yin, Lei; Wang, Kai; Cui, Xingang; Xu, Danfeng
2013-02-01
To assess the overall efficacy and safety of photoselective vaporization of the prostate (PVP) vs transurethral resection of the prostate (TURP) for treating patients with lower urinary tract symptoms (LUTS) secondary to benign prostate hyperplasia (BPH). A systematic search of the electronic databases, including MEDLINE, Embase, Web of Science and The Cochrane Library, as well as manual bibliography searches were performed. The pooled estimates of maximum flow rate (Q(max)), postvoid residual (PVR), quality of life (QoL), International Prostate Symptom Score (IPSS), operation duration, blood loss, catheterization time, hospital stay, capsule perforation, transfusion, transurethral resection (TUR) syndrome, urethral stricture and reintervention were calculated. At the 3-month follow-up, there was no significant difference in Q(max), PVR, QoL and IPSS between the TURP and PVP groups. At the 6-month follow-up, the pooled QoL favoured TURP, but there was no significant difference in the other variables between the two groups. PVP was associated with less blood loss, transfusion, capsular perforation, TUR syndrome, shorter catheterization time and hospital stay, but longer operation duration and higher reintervention rate. The efficacy of PVP was similar to that of TURP in relation to Q(max), PVR, QoL and IPSS, and it offered several advantages over TURP. As a promising minimal invasive technique, PVP could be used as an alternative surgical procedure for treating BPH. © 2012 BJU International.
Muñoz, Juan; Iglesias, Manuel; Chao, Eduardo Lloret; Bussy, Christian
2015-04-01
To assess ultrasound guided transarterial coil placement (UGTACP) for occlusion of the internal carotid artery (ICA) and external carotid artery (ECA) in horses. Cadaveric and in vivo study. Cadaveric horses (n = 10), healthy horses (3), and 1 clinical case. Cadaveric and in vivo (healthy horses): UGTACP was performed in the caudal part of the ICA and ECA. Coil placement in the rostral part of the ICA was performed blindly and controlled by conventional radiography. No coils were placed in the rostral part of the ECA. UGTACP of the ICA was in a horse with guttural pouch mycosis of the left guttural pouch. Accurate ultrasound-guided catheterization of the ICA and ECA was performed in all specimens. Ultrasound-guided coil placement was successfully performed in all cases except 1. No complications occurred in the in vivo study. The clinical case fully recovered and returned to its intended use. Based on our study, UGTACP of the ICA and ECA caudal part is a feasible alternative to fluoroscopy. An advantage of this technique is the accuracy with which you can catheterize both ICA and ECA and the ability to identify unusual branching at the origin of the ICA. Regarding the rostral part of the ICA, angiographic catheter guidance in this region is probably more precise using fluoroscopy as it is performed blindly. In a clinical situation, combination of US and fluoroscopy guidance can result in reduction of radiation exposure time. © Copyright 2014 by The American College of Veterinary Surgeons.
Karimi-Sari, Hamidreza; Faraji, Mehrdad; Mohazzab Torabi, Saman; Asjodi, Gholamreza
2014-01-01
Background: Central venous catheterization (CVC) is an important procedure in emergency departments (EDs). Despite existence of ultrasonography (US) devices in every ED, CVC is done using anatomical landmarks in many EDs in Iran. Objectives: This study aimed to compare the traditional landmark method vs. US-guided method of CVC placement in terms of complications and success rate. Patients and Methods: In this randomized controlled trial, patients who were candidate for internal jugular vein catheterization, and referred to Baqiyatallah Hospital ED were randomly allocated into US-guided CVC and anatomical landmarks guided CVC groups. Central vein access time, number of attempts, success rate, and complications in each group were evaluated. Mann-Whitney U, chi-square and Fisher exact tests along with Pearson and Spearman correlation coefficients were used to analyze the data. Results: Out of 100 patients, 56 were male and 44 were female. No significant differences were found between the US-guided and traditional landmark methods of CVC insertion in terms of age, gender, BMI, and site of catheter insertion. The mean access time was significantly lower in the US-guided group (37.12 ± 17.33 s vs. 63.42 ± 35.19 s, P < 0.001). The mean number of attempts was also significantly lower in the US-guided group (1.12 ± 0.3 vs. 1.58 ± 0.64 times, P < 0.001). Eighty-eight percent of patients in the US-guided group were catheterized in the first attempt, while 50% of patients in the traditional landmark group were catheterized in the second or more attempts (P < 0.001). The success rate was 100% in the US-guided group, while it was 88% in the landmark group (P = 0.013). Moreover, the rate of complications was significantly lower in the US-guided group (4% vs. 24%, P = 0.004). Conclusions: The US-guided method for CVC placement was superior to the traditional landmark method in terms of access time, number of attempts, success rate, and fewer complications. PMID:25741514
Topical EMLA cream versus prilocaine infiltration for pediatric cardiac catheterization.
Pirat, Arash; Karaaslan, Pelin; Candan, Selim; Zeyneloglu, Pinar; Varan, Birgul; Tokel, Kursat; Torgay, Adnan; Arslan, Gulnaz
2005-10-01
The aim of this study was to compare the anesthetic efficacy of prilocaine infiltration and a eutectic mixture of local anesthetics (EMLA) in cream for femoral vessel catheterization during pediatric cardiac catheterization and to evaluate whether EMLA cream application improves cannulation success. Prospective, randomized clinical trial. A university hospital. Forty American Society of Anesthesiologists class III and IV children scheduled for cardiac catheterization via the femoral route were included. The children were randomly assigned to 2 groups. The EMLA group (n = 20) had EMLA cream applied to the groin 60 minutes before the procedure, and the control group (n = 20) had prilocaine infiltrated at the site 5 minutes before the procedure. Boluses of intravenous midazolam, 0.1 mg/kg, and/or ketamine, 1 mg/kg, were given to achieve and maintain a predetermined sedation score of 2-3 (0 = deeply sedated, 5 = agitated) throughout the procedure (sedation monitored every 5 minutes). The groups were compared with respect to demographic data, hemodynamic and respiratory parameters/complications, amounts of additional sedative-analgesics required, cannulation time, and cannulation results (first-attempt success [right groin], second-attempt success [left groin], or failure on both attempts). Each group's "overall cannulation success rate" was calculated as the proportion of cases in which cannulation was achieved on the first or second attempt. The demographic data and the group findings for hemodynamic and respiratory parameters/complications, additional amounts of sedative-analgesics needed, cannulation times, and overall cannulation success rate were similar. The mean sedation score during femoral puncture in the EMLA group was significantly lower than that in the control group (3 +/- 1 v 4 +/- 1, respectively, p = 0.001). There were no other significant differences between the groups with respect to sedation scores during the procedure. The respective frequencies of first-attempt cannulation success in the EMLA and control groups were 75% and 45% (p = 0.05). The study showed that EMLA cream provides adequate topical anesthesia for femoral vessel cannulation during pediatric cardiac catheterization and may also increase the likelihood of cannulation success. However, use of this cream has no effect on sedative-analgesic requirements or on the risks of hemodynamic and respiratory complications during this procedure.
Walker, Jennifer N; Flores-Mireles, Ana L; Pinkner, Chloe L; Schreiber, Henry L; Joens, Matthew S; Park, Alyssa M; Potretzke, Aaron M; Bauman, Tyler M; Pinkner, Jerome S; Fitzpatrick, James A J; Desai, Alana; Caparon, Michael G; Hultgren, Scott J
2017-10-10
Methicillin-resistant Staphylococcus aureus (MRSA) is an emerging cause of catheter-associated urinary tract infection (CAUTI), which frequently progresses to more serious invasive infections. We adapted a mouse model of CAUTI to investigate how catheterization increases an individual's susceptibility to MRSA UTI. This analysis revealed that catheterization was required for MRSA to achieve high-level, persistent infection in the bladder. As shown previously, catheter placement induced an inflammatory response resulting in the release of the host protein fibrinogen (Fg), which coated the bladder and implant. Following infection, we showed that MRSA attached to the urothelium and implant in patterns that colocalized with deposited Fg. Furthermore, MRSA exacerbated the host inflammatory response to stimulate the additional release and accumulation of Fg in the urinary tract, which facilitated MRSA colonization. Consistent with this model, analysis of catheters from patients with S. aureus -positive cultures revealed colocalization of Fg, which was deposited on the catheter, with S. aureus Clumping Factors A and B (ClfA and ClfB) have been shown to contribute to MRSA-Fg interactions in other models of disease. We found that mutants in clfA had significantly greater Fg-binding defects than mutants in clfB in several in vitro assays. Paradoxically, only the ClfB - strain was significantly attenuated in the CAUTI model. Together, these data suggest that catheterization alters the urinary tract environment to promote MRSA CAUTI pathogenesis by inducing the release of Fg, which the pathogen enhances to persist in the urinary tract despite the host's robust immune response.
Tarcan, Tufan; Akbal, Cem; Sekerci, Cağri A; Top, Tuncay; Simşek, Ferruh
2014-04-01
This was a prospective single-arm study to assess the efficacy and safety of intradetrusor injections of onabotulinum toxin-A in children with urinary incontinence associated with neurogenic detrusor overactivity due to myelomeningocele. All patients had failed the first-line treatment of a combination of oral antimuscarinics and intermittent catheterization. The study group consisted of 31 children with myelomeningocele with a mean age of 7.95 years (range, 5-3 years) who were followed up for a mean of 29 weeks. The amount of onabotulinum toxin A injected was 10 U/kg with a maximal dose of 300 U. There were 20 to 30 injection sites with rigid cystoscopic guidance under general anesthesia. Thirty of 31 patients reported dryness between intermittent catheterization intervals. The mean reduction in maximum detrusor pressure and the mean increase in maximum cystometric capacity from baseline were 53% and 51.5%, respectively, 6 weeks after injection. We found a 324% increase in mean bladder compliance and a 57% increase in mean intermittent catheterization volumes. The mean duration of efficacy was 28 weeks with a single injection and 36 weeks for repeated injections (minimum, 16 weeks; maximum, 52 weeks). The mean time interval between repeated onabotulinum toxin-A injections was 7 months (maximum, 13 months). Intradetrusor injections of onabotulinum toxin-A were well tolerated. Onabotulinum toxin-A injections into the bladder wall provide a significant symptomatic and urodynamic improvement in children with neurogenic detrusor overactivity due to myelomeningocele who are on intermittent catheterization. The treatment seems to be safe and very well tolerated.
The Feasibility of Clean Intermittent Self-Catheterization Teaching in an Outpatient Setting.
Bickhaus, Jennifer A; Drobnis, Erma Z; Critchlow, William A; Occhino, John A; Foster, Raymond T
2015-01-01
The aim of this study was to evaluate the feasibility of teaching clean intermittent self-catheterization (CISC) in an outpatient setting to women planning surgery for pelvic organ prolapse (POP) and/or urinary incontinence (UI). This was a prospective observational study of 55 women who planned surgical correction of POP and/or UI. All women were taught CISC as part of their preoperative education. The ability to learn CISC and the amount of time needed to teach CISC were recorded. Multivariate modeling, χ2 test, Fisher exact test, and Kruskal-Wallis analysis of variance were used for statistical analysis. Of the 55 subjects consecutively enrolled, 51 subjects (93%) were able to learn CISC and demonstrate competency (P < 0.00001). Four subjects (7%) were unable to learn CISC. The median time to teach CISC with demonstrated proficiency was 3.7 minutes (range, 1.8-7.4 minutes). Of the subjects who learned CISC and had surgery, the mean (SD) time in days from preoperative teaching to the postoperative voiding trial was 16 (11) days (range, 2-39 days). Of the 41 subjects who completed the postoperative voiding trial and had data recorded, 33 (80%) were able to self-catheterize without nurse assistance or with minimal verbal coaching, whereas 8 (20%) subjects required hands-on nursing assistance or were unable to perform CISC (P < 0.001). Clean intermittent self-catheterization can be taught to most patients undergoing POP/UI surgery in a short time (median, 3.7 minutes). The overwhelming majority of patients are able to retain the CISC skill weeks after being taught in the clinic.
Schimmel, Daniel R; Sweis, Ranya; Cohen, Elaine R; Davidson, Charles; Wayne, Diane B
2016-02-15
The purpose of this study is to determine the effects of simulation-based medical education (SBME) on the skills required to perform coronary angiography in the cardiac catheterization laboratory. Cardiovascular fellows commonly learn invasive procedures on patients. Because this approach is not standardized, it can result in inconsistent skill acquisition through exclusion of concepts and skills. Also, the learning curve varies between trainees yielding variability in skill acquisition. Therefore, coronary angiography skills are an excellent target for SBME in an environment in which direct patient care is not jeopardized. From January 2013 to June 2013, 14 cardiovascular fellows entering the cardiac catheterization laboratory at a tertiary care teaching hospital were tested on an endovascular simulator to assess baseline skills. All fellows subsequently underwent didactic teaching and preceptor-lead training on the endovascular simulator. Topics included basic catheterization skills and a review of catheterization laboratory systems. Following training, all fellows underwent a post-training assessment on the endovascular simulator. Paired t tests were used to compare items on the skills checklist and simulator defined variables. Cardiovascular fellows scored significantly higher on a diagnostic coronary angiography skills checklist following SBME using an endovascular simulator. The mean pretest score was 66.6% (SD = 9.7%) compared to 86.0% (SD = 6.3%) following simulator training (P < 0.001). Additional findings include significant reduction in procedure time and use of cine-fluoroscopy at posttest. SBME significantly improved cardiovascular fellows' performance of simulated coronary angiography skills. Standardized simulation-based education is a valuable adjunct to traditional clinical education for cardiovascular fellows. © 2015 Wiley Periodicals, Inc.
Simulator training to minimize ionizing radiation exposure in the catheterization laboratory.
Katz, Aric; Shtub, Avraham; Solomonica, Amir; Poliakov, Adva; Roguin, Ariel
2017-03-01
To learn about radiation and how to lower it. Patients and operators are routinely exposed to high doses of ionizing radiation during catheterization procedures. This increased exposure to ionizing radiation is partially due to a lack of awareness to the effects of ionizing radiation, and lack of knowledge on the distribution and behavior of scattered radiation. A simulator, which incorporates data on scattered ionizing radiation, was built based on multiple phantom measurements and used for teaching radiation safety. The validity of the simulator was confirmed in three catheterization laboratories and tested by 20 interventional cardiologists. All evaluators were tested by an objective knowledge examination before, immediately following, and 12 weeks after simulator-based learning and training. A subjective Likert questionnaire on satisfaction with simulation-based learning and training was also completed. The 20 evaluators learned and retained the knowledge that they gained from using the simulator: the average scores of the knowledge examination pre-simulator training was 54 ± 15% (mean ± standard deviation), and this score significantly increased after training to 94 ± 10% (p < 0.001). The evaluators also reported high levels of satisfaction following simulation-based learning and training according to the results of the subjective Likert questionnaire. Simulators can be used to train cardiology staff and fellows and to further educate experienced personnel on radiation safety. As a result of simulator training, the operator gains knowledge, which can then be applied in the catheterization laboratory in order to reduce radiation doses to the patient and to the operator, thereby improving the safety of the intervention.
Walker, Jennifer N.; Flores-Mireles, Ana L.; Pinkner, Chloe L.; Schreiber, Henry L.; Joens, Matthew S.; Park, Alyssa M.; Potretzke, Aaron M.; Bauman, Tyler M.; Pinkner, Jerome S.; Fitzpatrick, James A. J.; Desai, Alana; Caparon, Michael G.
2017-01-01
Methicillin-resistant Staphylococcus aureus (MRSA) is an emerging cause of catheter-associated urinary tract infection (CAUTI), which frequently progresses to more serious invasive infections. We adapted a mouse model of CAUTI to investigate how catheterization increases an individual’s susceptibility to MRSA UTI. This analysis revealed that catheterization was required for MRSA to achieve high-level, persistent infection in the bladder. As shown previously, catheter placement induced an inflammatory response resulting in the release of the host protein fibrinogen (Fg), which coated the bladder and implant. Following infection, we showed that MRSA attached to the urothelium and implant in patterns that colocalized with deposited Fg. Furthermore, MRSA exacerbated the host inflammatory response to stimulate the additional release and accumulation of Fg in the urinary tract, which facilitated MRSA colonization. Consistent with this model, analysis of catheters from patients with S. aureus-positive cultures revealed colocalization of Fg, which was deposited on the catheter, with S. aureus. Clumping Factors A and B (ClfA and ClfB) have been shown to contribute to MRSA–Fg interactions in other models of disease. We found that mutants in clfA had significantly greater Fg-binding defects than mutants in clfB in several in vitro assays. Paradoxically, only the ClfB− strain was significantly attenuated in the CAUTI model. Together, these data suggest that catheterization alters the urinary tract environment to promote MRSA CAUTI pathogenesis by inducing the release of Fg, which the pathogen enhances to persist in the urinary tract despite the host’s robust immune response. PMID:28973850
[Infections on catheters in hemodialysis: Temporal fluctuations of the infectious risk].
Izoard, S; Ayzac, L; Meynier, J; Seghezzi, J-C; Jolibois, B; Tolani, M L
2017-11-01
International guidelines recommend to limit the long-term use of central-veinous catheters in patients undergoing hemodialysis, because they expose the patient to a higher infectious risk than the fistulas. However, for some patients with comorbidity, switching to a permanent vascular access is not possible. In such case, the catheter is used for a longer period. It seems therefore important to study the influence of a prolonged duration of catheterization on infectious complications. The temporal fluctuation profile of the infectious risk is poorly studied in the literature and the results published may be contradictory. This multicentric prospective study included 1053 incident tunneled catheters. Multivariate logistic regression was used to identify significant risk factors of infection. An infection-free survival analysis was performed afterwards to estimate the variation of the instantaneous infectious risk during catheterization. The major risks factors of infections on tunneled catheters were: previous Staphylococcus aureus infection (aOR=1.95 [1.16-3.27]; P=0.012), diabetes (aOR=1.67 [1.16-2.41]; P=0.006), and long duration of catheterization (0-3months vs.≥24months: aOR=2.42 [1.34-4.36]; P=0.003). The survival analysis showed a higher risk of infections of tunneled catheters during the first months after placement. Risk declines over time. The fluctuation profile of the infectious risk show that preventive precautions should target the first months of catheterization. Copyright © 2017 Société francophone de néphrologie, dialyse et transplantation. Published by Elsevier Masson SAS. All rights reserved.
Arab Hassani, Faezeh; Mogan, Roshini P; Gammad, Gil G L; Wang, Hao; Yen, Shih-Cheng; Thakor, Nitish V; Lee, Chengkuo
2018-04-24
Aging, neurologic diseases, and diabetes are a few risk factors that may lead to underactive bladder (UAB) syndrome. Despite all of the serious consequences of UAB, current solutions, the most common being ureteric catheterization, are all accompanied by serious shortcomings. The necessity of multiple catheterizations per day for a physically able patient not only reduces the quality of life with constant discomfort and pain but also can end up causing serious complications. Here, we present a bistable actuator to empty the bladder by incorporating shape memory alloy components integrated on flexible polyvinyl chloride sheets. The introduction of two compression and restoration phases for the actuator allows for repeated actuation for a more complete voiding of the bladder. The proposed actuator exhibits one of the highest reported voiding percentages of up to 78% of the bladder volume in an anesthetized rat after only 20 s of actuation. This amount of voiding is comparable to the common catheterization method, and its one time implantation onto the bladder rectifies the drawbacks of multiple catheterizations per day. Furthermore, the scaling of the device for animal models larger than rats can be easily achieved by adjusting the number of nitinol springs. For neurogenic UAB patients with degraded nerve function as well as degenerated detrusor muscle, we integrate a flexible triboelectric nanogenerator sensor with the actuator to detect the fullness of the bladder. The sensitivity of this sensor to the filling status of the bladder shows its capability for defining a self-control system in the future that would allow autonomous micturition.
Experience with the Cardiva Boomerang Catalyst system in pediatric cardiac catheterization.
Seltzer, Sharon; Alejos, Juan Carlos; Levi, Daniel S
2009-09-01
We studied the safety and efficacy of the Cardiva Boomerang Catalyst vascular closure system in pediatric patients after cardiac catheterization with access in femoral and internal jugular vessels. Recurrent catheterization and advances in pediatric interventions increase the need for easy hemostasis without a residual foreign body that may prevent re-accessing the vessel. The Boomerang can be deployed in sheaths as small as 4Fr without residual foreign body, with minimal orientation needed, and few complications reported. In a two-month period, all patients between 18 months and 21 years old catheterized with 4-8Fr sheaths less than 15 cm long were eligible for Boomerang placement. These were compared retrospectively with control patients with manual hemostasis. Anthropomorphic measurements, procedure type, activated clotting time, and sheath size as well as total times of cases, intubation, hemostasis, and extubation were compared between the two groups. Forty-six Boomerangs were deployed in 31 patients and compared with 40 patients with manual hemostasis. Boomerangs were deployed in femoral vessels and the internal jugular vein. Device success with hemostasis was achieved in 39 patients (85%). There were no significant differences in time to hemostasis or extubation between the two groups. No major complications or operator error occurred, including hematoma, transfusion, retroperitoneal bleed, infection, vessel occlusion, or need for surgery. The Boomerang is a safe and easy means of achieving hemostasis in the pediatric population, in femoral vessels as well as internal jugular veins. Its times to hemostasis and extubation were not significantly different from manual hold. 2009 Wiley-Liss, Inc.
Reisner, Andreas; Maierl, Mario; Jörger, Michael; Krause, Robert; Berger, Daniela; Haid, Andrea; Tesic, Dijana; Zechner, Ellen L
2014-03-01
Biofilm formation on catheters is thought to contribute to persistence of catheter-associated urinary tract infections (CAUTI), which represent the most frequent nosocomial infections. Knowledge of genetic factors for catheter colonization is limited, since their role has not been assessed using physicochemical conditions prevailing in a catheterized human bladder. The current study aimed to combine data from a dynamic catheterized bladder model in vitro with in vivo expression analysis for understanding molecular factors relevant for CAUTI caused by Escherichia coli. By application of the in vitro model that mirrors the physicochemical environment during human infection, we found that an E. coli K-12 mutant defective in type 1 fimbriae, but not isogenic mutants lacking flagella or antigen 43, was outcompeted by the wild-type strain during prolonged catheter colonization. The importance of type 1 fimbriae for catheter colonization was verified using a fimA mutant of uropathogenic E. coli strain CFT073 with human and artificial urine. Orientation of the invertible element (IE) controlling type 1 fimbrial expression in bacterial populations harvested from the colonized catheterized bladder in vitro suggested that the vast majority of catheter-colonizing cells (up to 88%) express type 1 fimbriae. Analysis of IE orientation in E. coli populations harvested from patient catheters revealed that a median level of ∼73% of cells from nine samples have switched on type 1 fimbrial expression. This study supports the utility of the dynamic catheterized bladder model for analyzing catheter colonization factors and highlights a role for type 1 fimbriae during CAUTI.
Flow meter urine testing: a practical proposition in patients attending for urodynamics?
Hashim, Hashim; Abrams, Paul
2006-05-01
To find a practical way of detecting urinary tract infection (UTI) before invasive urodynamic testing, as UTIs after urodynamics are well documented, but there are no standard guidelines about when urine should be analysed before urodynamics. Before urodynamics all patients are asked to provide a free urine flow; the patient is then catheterized to obtain a catheter-specimen of urine that is tested for infection by a urine dipstick. If the dipstick is found positive for nitrites and/or leukocytes, the test is abandoned and the sample sent for microscopy, culture and sensitivity. In the present study, patients were asked to provide a free urine flow into the flowmeter as usual. Between patients, the flowmeter was washed with soap and water and dried, so that there would be no cross-contamination between patients' urine results. Urine was collected as usual and tested using a dipstick, the patient was then catheterized and another dipstick test done on the catheter specimen of urine (CSU), to compare results. Pairs of urine samples, when positive for nitrite were 100% consistent, and 89% of pairs positive for leukocytes were the same before and after catheterization. The remaining 11% (all women) of the positive leukocyte group had leukocytosis on testing the flowmeter urine but not on the CSU, possibly due to contamination from the vagina. Testing urine by dipstick in the sample from the flowmeter is a feasible option, thus saving the patient an inappropriate catheterization, with the risk of bacteraemia during urodynamics, and allowing the flowrate to be measured.
Kodak EDR2 film for patient skin dose assessment in cardiac catheterization procedures.
Morrell, R E; Rogers, A T
2006-07-01
Patient skin doses were measured using Kodak EDR2 film for 20 coronary angiography (CA) and 32 percutaneous transluminal coronary angioplasty (PTCA) procedures. For CA, all skin doses were well below 1 Gy. However, 23% of PTCA patients received skin doses of 1 Gy or more. Dose-area product (DAP) was also recorded and was found to be an inadequate indicator of maximum skin dose. Practical compliance with ICRP recommendations requires a robust method for skin dosimetry that is more accurate than DAP and is applicable over a wider dose range than EDR2 film.
Metastatic Blue Nevus-Like Melanoma Detected by Liquid-Based Catheterized Urine Cytology.
Kim, Sue Kyung; Yang, Ji Young; Han, Jae Ho; Kwon, Ji Eun
2018-06-01
Primary or metastatic malignant melanoma can mimic benign blue nevus in rare cases, making the diagnosis challenging. Herein, we report an exceptionally rare case of blue nevus-like melanoma and its blue nevus-like metastasis which was detected by catheterized urine cytology. The patient presented with blue-colored papuloplaques on his temple which were diagnosed as blue nevus-like melanoma on punch biopsies. While he was admitted for administration of chemotherapy, hematuria was detected. Catheterized urine cytology revealed singly scattered oval to spindle-shaped pigmented cells with a moderate degree of variation in shape and size. Many of them had small nuclei with indiscernible to inconspicuous nucleoli while only a few cells showed nuclear enlargement and nuclear hyperchromasia, which could be diagnostic pitfalls. Most of the cells on the smear were positive for HMB45 immunostaining, which confirmed the diagnosis of metastatic blue nevus-like melanoma. To the best of our knowledge, the present case is the first report describing cytomorphologic findings of blue nevus-like metastasis of melanoma in the urine specimen.
Boonbaichaiyapruck, S; Hutayanon, P; Chanthanamatta, P; Dumrongwatana, T; Intarayotha, N; Krisdee, V; Yamvong, S
2001-12-01
Post cardiac catheterization puncture site care is usually done with a tight pressure dressing by an elastic adhesive bandage (Tensoplast) due to the belief that it should prevent bleeding. The practice is uncomfortable to the patients. The authors compared a new way of dressing using light transparent tape (Tegaderm) to the conventional tight pressure one. 126 post coronary angiography patients were randomized to have their groins dressed either with Tensoplast or with Tegaderm. Patients ambulated 8 hours after the procedures. The groin was evaluated for pain, discomfort and bleeding complications. 49 per cent in the Tensoplast vs 26.9 per cent in the Tegaderm group experienced pain (p value of 0.01). 55.5 per cent in the Tensoplast group vs 11.1 per cent in the Tegaderm group reported discomfort. 4.7 per cent in the Tensoplast vs 1.6 per cent in the Tegaderm group developed bleeding or hematoma. Dressing of the puncture site after cardiac catheterization with Tegaderm was more comfortable than the conventional Tensoplast without any difference in bleeding complications.
Detection of patent foramen ovale by contrast transesophageal echocardiography.
Chen, W J; Kuan, P; Lien, W P; Lin, F Y
1992-06-01
A series of 32 patients undergoing cardiac catheterization and/or operation to document the presence of patent foramen ovale (PFO) were studied. All were examined by contrast transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) during normal breathing and the Valsalva maneuver. A right-to-left shunt at the atrial level was visualized by contrast TEE in 14 patients during normal breathing and in 20 patients during the Valsalva maneuver. In comparison, contrast TTE revealed this shunt in only eight patients during normal breathing and in 12 patients during the Valsalva maneuver. All of the foramina proved to be patent by contrast TTE were also found by contrast TEE. All but one (19 of 20) patients, shown to have PFO by contrast TEE, could be confirmed at cardiac catheterization and/or operation. Using cardiac catheterization and/or operation as a gold standard, contrast TEE appears to be a more sensitive (100 percent vs 63 percent, p less than 0.005) and accurate (97 percent vs 78 percent, p less than 0.05) method than contrast TTE in the detection of PFO.
NASA Astrophysics Data System (ADS)
Wang, Yaoping; Chui, Cheekong K.; Cai, Yiyu; Mak, KoonHou
1998-06-01
This study presents an approach to build a 3D vascular system of coronary for the development of a virtual cardiology simulator. The 3D model of the coronary arterial tree is reconstructed from the geometric information segmented from the Visible Human data set for physical analysis of catheterization. The process of segmentation is guided by a 3D topologic hierarchy structure of coronary vessels which is obtained from a mechanical model by using Coordinate Measuring Machine (CMM) probing. This mechanical professional model includes all major coronary arterials ranging from right coronary artery to atrioventricular branch and from left main trunk to left anterior descending branch. All those branches are considered as the main operating sites for cardiology catheterization. Along with the primary arterial vasculature and accompanying secondary and tertiary networks obtained from a previous work, a more complete vascular structure can then be built for the simulation of catheterization. A novel method has been developed for real time Finite Element Analysis of catheter navigation based on this featured vasculature of vessels.
Serum corticosterone response to adrenocorticotropic hormone stimulation in Florida sandhill cranes.
Ludders, J W; Langenberg, J A; Czekala, N M; Erb, H N; McCormick, H
1998-10-01
Florida sandhill cranes (Grus canadensis pratensis) were conditioned to confinement in an enclosure for 7 days, 6 hr a day. On day 8, cranes were catheterized and then confined in an enclosure. Venous blood (2 ml) was collected through the catheter and an attached IV line immediately before (-60 min) and 60 min after (0 min) confinement. Using a randomization table and a restricted cross-over experimental design, cranes were injected intravenously with either saline (control) or adrenocorticotropic hormone (ACTH; cosyntropin, Cortrosyn; 0.25 mg). At 30, 60, 120, 180, 240 and 300 min after injection, blood samples were collected and assayed for corticosterone. The cranes receiving ACTH increased their serum corticosterone concentrations as much as fivefold above baseline concentrations. Serum corticosterone concentrations remained significantly elevated for approximately 60 min after ACTH stimulation. Physical restraint and catheterization caused an increase in serum corticosterone almost comparable to that induced by ACTH stimulation. In cranes injected with saline, serum corticosterone decreased within 1 hr after physical restraint and catheterization, and remained at lower levels throughout the remaining 5 hr of confinement.
[Urologic examination and treatment of patients with acute injuries of the spinal medulla].
Jeppesen, L J; Krarup, T; Walter, S; Haase, J
1989-08-07
During a period of one year, nine patients with traumatic lesions of the spinal medulla were examined and treated urologically. The patients were followed-up for 24-36 months and follow-up will continue. All of the patients were treated primarily with sterile intermittent catheterization by the nursing staff. Exceptions from this were patients in whom indwelling catheters were necessary on account of complicating conditions. During the acute phase, the patients were examined by a urologist and bladder function investigations with cystometry + electromyographic registration from the pelvic floor were undertaken. When patients had recovered from the spinal shock phase, emptying of the bladder supplemented by alpha-adrenergic blocking preparations and clean intermittent catheterization were instituted in the patients with supra-sacral lesions. Patients with infra-sacral bladder paresis were trained in miction on abdominal pressure supplemented by clean intermittent catheterization. No complications from this treatment have occurred and renal function has remained stable. Only one patient has an indwelling catheter and it has not proved possible to persuade the patient to accept removal.
Eosinophilic cystitis with recurrent urinary retention: case report.
Park, Hongzoo
2017-01-01
Eosinophilic cystitis is a rare inflammatory disease of the bladder whose origin, pathogenesis, and treatment are unknown. Frequency, dysuria, and hematuria are frequent symptoms. Here, we report a rare occurrence of recurrent urinary retention and repetitive catheterization. A 67-year-old male presented with acute urinary retention and intermittent gross hematuria of 2 weeks duration. Urethral catheterization followed by a trial without catheter, was successful. Complete blood count showed presence of eosinophils (eosinophilia) and computed tomography of kidneys, ureter and bladder with contrast showed thickened bladder wall and small prostate. Cystoscopy revealed an erythematous lesion over the anterior wall. The rest of the mucosa was normal. Transurethral biopsies of the lesion were performed and histologic examination showed features of eosinophilic cystitis. Despite multiple medication regimens containing corticosteroids and antihistamines, he presented with recurrent urinary retention, approximately once every month. After 6 months, he was started on bethanechol, which led to no catheterization for up to 2 years. To the best of our knowledge, this is the first report on the successful use of bethanechol as a treatment for eosinophilic cystitis with recurrent urinary retention.
Kałużna-Oleksy, Marta; Araszkiewicz, Aleksander; Migaj, Jacek; Lesiak, Maciej; Straburzyńska-Migaj, Ewa
2017-01-01
Pulmonary hypertension (PH), second only to left heart diseases (LHD), is a frequent problem in clinical practice. At the same time, left heart diseases represent the most common cause of pulmonary hypertension, and the occurrence of PH in patients with chronic heart failure is usually associated with worse functional class, and prognosis. Right heart catheterization (RHC) is the "gold standard" in the diagnosis and differentiation of PH. It is also essential in the process of qualifying for a heart transplantation. Therefore, right heart catheterization should be performed in expert centers by experienced operators and according to a strict protocol to ensure the reliability and reproducibility of results. Recommendations for pulmonary hypertension due to left heart disease are based on the European Society of Cardiology (ESC) guidelines designed in cooperation with the European Respiratory Society (ERS) and the International Society for Heart and Lung Transplantation (ISHL). The new ESC guidelines for pulmonary hypertension published in 2015 have improved the diagnostic and therapeutic process in patients with left heart diseases.
Sonographic diagnosis of hepatic erosion caused by umbilical catheterization.
Schiavone, R; Narese, D; Ognibene, N; Rossi, E; Antonello, M; Basile, M; Di Maurizio, M; Defilippi, C
2016-01-01
The use of umbilical venous catheter (UVC) is common practice in neonatal units. The traumatic injury of the hepatic parenchyma is a rare complication. We present a case of a preterm newborn underwent ultrasound examination revealing a hyperechogenic focal lesion at the confluence of the hepatic veins This finding, according to patient's history, was suspected to be a traumatic injury of the liver parenchyma caused by umbilical catheterization. During sonographic follow-up this lesion gradually reduced until complete resolution. Finally, when focal hyperechogenic hepatic lesion is incidentally detected in newborn with history of UVC placement, the radiologists must consider the traumatic etiology.
Central venous catheterization training: current perspectives on the role of simulation
Soffler, Morgan I; Hayes, Margaret M; Smith, C Christopher
2018-01-01
Simulation is a popular and effective training modality in medical education across a variety of domains. Central venous catheterization (CVC) is commonly undertaken by trainees, and carries significant risk for patient harm when carried out incorrectly. Multiple studies have evaluated the efficacy of simulation-based training programs, in comparison with traditional training modalities, on learner and patient outcomes. In this review, we discuss relevant adult learning principles that support simulation-based CVC training, review the literature on simulation-based CVC training, and highlight the use of simulation-based CVC training programs at various institutions. PMID:29872360
International Meeting on Simulation in Healthcare 2007
2007-03-01
Research Abstract : 32 Simulationbased Training in Ultrasound Assisted Central Venous Catheterization . Pamela Andreatta 1 , Rajani Mangrulkar 2...vascular access skill training for central venous catheterization , and basic and difficult airway management skill training with infant/pediatric/adult task...Office of Clinical Affairs, University of Michigan Health System Background: More than 5 million central venous catheters (CVCs) are inserted in the
[Selective arteriography of the supra-aortic trunks by right humeral approach with a 4F catheter].
Rodde, A; Bazin, C; Blum, A; Boccaccini, H; Boyer, B; Claudon, M; Regent, D
1993-12-01
Three hundred and sixty seven patients were studied for cerebrovascular disease with intra-arterial digital subtraction. Examination were performed using a right transbrachial approach with a 4F catheter. Selective catheterization of the carotid arteries was possible in 98% for the left and 99% for the right. Image quality was consistently good or excellent. There was 2 neurologic complications and 1 local complication (hematoma) requiring surgery few weeks later. Selective carotid and vertebral catheterizations by the brachial route is safe, simple, accurate and rapid (15 mn) and can be employed in outpatients.
Treatment of immobilization hypercalciuria using weekly alendronate in two quadriplegic patients.
Atalay, Ayce; Turhan, Nur
2008-01-01
Metabolic and urinary problems encountered in spinal cord injury patients are multifaced. We report two patients with high-level spinal cord injuries who have developed hypercalciuria after admission to the rehabilitation unit. To establish a clean intermittent self-catheterization programme, the hypercalciuria was treated successfully with alendronate. Twenty-four-hour urinary calcium excretion decreased significantly after medical treatment for hypercalciuria. Since high-level quadriplegic patients may not be mobilized in the acute phase of the rehabilitation, use of alendronate for preventing hypercalciuria and maintaining a successful clean intermittent self-catheterization programme can be considered as a supportive/complementary measure.
Central venous catheterization training: current perspectives on the role of simulation.
Soffler, Morgan I; Hayes, Margaret M; Smith, C Christopher
2018-01-01
Simulation is a popular and effective training modality in medical education across a variety of domains. Central venous catheterization (CVC) is commonly undertaken by trainees, and carries significant risk for patient harm when carried out incorrectly. Multiple studies have evaluated the efficacy of simulation-based training programs, in comparison with traditional training modalities, on learner and patient outcomes. In this review, we discuss relevant adult learning principles that support simulation-based CVC training, review the literature on simulation-based CVC training, and highlight the use of simulation-based CVC training programs at various institutions.
Carbon Dioxide Angiography: Scientific Principles and Practice
Cho, Kyung Jae
2015-01-01
Carbon dioxide (CO2) is a colorless, odorless gas which occurs naturally in the atmosphere and human body. With the advent of digital subtraction angiography, the gas has been used as a safe and useful alternative contrast agent in both arteriography and venography. Because of its lack of renal toxicity and allergic potential, CO2 is a preferred contrast agent in patients with renal failure or contrast allergy, and particularly in patients who require large volumes of contrast medium for complex endovascular procedures. Understanding of the unique physical properties of CO2 (high solubility, low viscosity, buoyancy, and compressibility) is essential in obtaining a successful CO2 angiogram and in guiding endovascular intervention. Unlike iodinated contrast material, CO2 displaces the blood and produces a negative contrast for digital subtraction imaging. Indications for use of CO2 as a contrast agent include: aortography and runoff, detection of bleeding, renal transplant arteriography, portal vein visualization with wedged hepatic venous injection, venography, arterial and venous interventions, and endovascular aneurysm repair. CO2 should not be used in the thoracic aorta, the coronary artery, and cerebral circulation. Exploitation of CO2 properties, avoidance of air contamination and facile catheterization technique are important to the safe and effective performance of CO2 angiography and CO2-guided endovascular intervention. PMID:26509137
Cardiac surgery or interventional cardiology? Why not both? Let's go hybrid.
Papakonstantinou, Nikolaos A; Baikoussis, Nikolaos G; Dedeilias, Panagiotis; Argiriou, Michalis; Charitos, Christos
2017-01-01
A hybrid strategy, firstly performed in the 1990s, is a combination of tools available only in the catheterization laboratory with those available only in the operating room in order to minimize surgical morbidity and face with any cardiovascular lesion. The continuous evolution of stent technology along with the adoption of minimally invasive surgical approaches, make hybrid approaches an attractive alternative to standard surgical or transcatheter techniques for any given set of cardiovascular lesions. Examples include hybrid coronary revascularization, when an open surgical anastomosis of the left internal mammary artery to the left anterior descending coronary artery is performed along with stent implantation in non-left anterior descending coronary vessels, open heart valve surgery combined with percutaneous coronary interventions to coronary lesions, hybrid aortic arch debranching combined with endovascular grafting for thoracic aortic aneurysms, hybrid endocardial and epicardial atrial fibrillation procedures, and carotid artery stenting along with coronary artery bypass grafting. The cornerstone of success for all of these methods is the productive collaboration between cardiac surgeons and interventional cardiologists. The indications and patient selection of these procedures are still to be defined. However, high-risk patients have already been shown to benefit from hybrid approaches. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Local anesthesia and hydro-distension to facilitate cystic calculus removal in horses.
Russell, Tom; Pollock, Patrick J
2012-07-01
To report a technique for improving surgical access to the bladder for removal of cystic calculi in male horses. Retrospective case series. Geldings (8) with cystic calculi. After catheterization of the bladder through the penis, 100 mL 2% lidocaine hydrochloride solution was instilled. After 10 minutes, the bladder was distended with sterile, warmed Hartmann's solution to a pressure of ≈ 40 cm H(2) O, using gravity feed. This was left in place until abdominal access was gained at surgery, then the fluid siphoned off via the catheter. Calculi were 3-11 cm in diameter (median, 6 cm). Bladder capacity ranged from 1.4 to 2.5 L (median, 1.8 L). Exteriorization time from placing a hand in the abdomen to having the bladder in a surgically accessible position was <5 minutes. The described technique facilitates exteriorization of the bladder for removal of cystic calculi. Copyright 2012 by The American College of Veterinary Surgeons.
Non-invasive pressure difference estimation from PC-MRI using the work-energy equation
Donati, Fabrizio; Figueroa, C. Alberto; Smith, Nicolas P.; Lamata, Pablo; Nordsletten, David A.
2015-01-01
Pressure difference is an accepted clinical biomarker for cardiovascular disease conditions such as aortic coarctation. Currently, measurements of pressure differences in the clinic rely on invasive techniques (catheterization), prompting development of non-invasive estimates based on blood flow. In this work, we propose a non-invasive estimation procedure deriving pressure difference from the work-energy equation for a Newtonian fluid. Spatial and temporal convergence is demonstrated on in silico Phase Contrast Magnetic Resonance Image (PC-MRI) phantoms with steady and transient flow fields. The method is also tested on an image dataset generated in silico from a 3D patient-specific Computational Fluid Dynamics (CFD) simulation and finally evaluated on a cohort of 9 subjects. The performance is compared to existing approaches based on steady and unsteady Bernoulli formulations as well as the pressure Poisson equation. The new technique shows good accuracy, robustness to noise, and robustness to the image segmentation process, illustrating the potential of this approach for non-invasive pressure difference estimation. PMID:26409245
Value and limitations of auscultation in the management of congenital heart disease.
McNamara, D G
1990-02-01
With advances in technology, especially that of ultrasonography, the art and science of auscultation could become relegated to that of an obsolete technique. Physicians in a cardiovascular training program involved in learning modern instrumentation diagnostic techniques often become expert in these areas before they have mastered the use of the stethoscope. Although the technology of ultrasonic examination, cardiac catheterization, and angiocardiography must be learned, the value of auscultation of the heart cannot be ignored. Many highly competent physicians who are responsible for diagnosis and treatment of the pediatric patient, including some pediatric cardiologists, may not be aware that they have not yet become experts at auscultation. The skill of auscultation of the heart must be learned by supervised experience with patients in whom a wide variety of normal and abnormal heart sounds and murmurs can be heard. Once learned, the skill can be maintained only by frequent practice in hearing and evaluating both subtle and obvious sounds emanating from the heart and from the pulmonary and systemic blood vessels.
Van Nostrand, D; Janowitz, W R; Holmes, D R; Cohen, H A
1979-01-01
The ability of equilibrium gated radionuclide ventriculography to detect segmental left ventricular (LV) wall motion abnormalities was determined in 26 patients undergoing cardiac catheterization. Multiple gated studies obtained in 30 degrees right anterior oblique and 45 degrees left anterior oblique projections, played back in a movie format, were compared to the corresponding LV ventriculograms. The LV wall in the two projections was divided into eight segments. Each segment was graded as normal, hypokinetic, akinetic, dyskinetic, or indeterminate. Thirteen percent of the segments in the gated images were indeterminate; 24 out of 27 of these were proximal or distal inferior wall segments. There was exact agreement in 86% of the remaining segments. The sensitivity of the radionuclide technique for detecting normal versus any abnormal wall motion was 71%, with a specificity of 99%. Equilibrium gated ventriculography is an excellent noninvasive technique for evaluating segmental LV wall motion. It is least reliable in assessing the proximal inferior wall and interventricular septum.
Colon pouch (Mainz III) for continent urinary diversion.
Stolzenburg, Jens-Uwe; Schwalenberg, Thilo; Liatsikos, Evangelos N; Sakelaropoulos, George; Rödder, Kilian; Hohenfellner, Rudolph; Fisch, Margit
2007-06-01
To evaluate the use of a continent cutaneous pouch made exclusively of colon (Mainz pouch III), as excellent results with the Mainz pouch III in irradiated patients suggested that the indication for this type of urinary diversion could be extended. The outcome of 24 patients with continent cutaneous urinary diversions using colon segments (Mainz pouch III) was investigated retrospectively. Overall, 22 of the patients had a malignant disease and two a benign disease; 16 had a hysterectomy and pelvic exenteration for gynaecological tumours; two men with a rhabdomyosarcoma of the prostate had a radical cystoprostatectomy; one woman had pelvic exenteration for bladder cancer; one man had a simultaneous rectum resection due to infiltrating rectal cancer, and another a left nephrectomy with cystectomy for concomitant kidney and bladder tumour. Benign indications were hyper-reflexive bladder after polytrauma and two cases of neurogenic bladder dysfunction. Eighteen patients had radiotherapy (32-48 Gy) before the urinary diversion. The mean (range) follow-up was 35 (12-65) months. The mean pouch capacity was 293.8 mL. Three patients died during the follow-up (two from disease progression and one suicide); 20 patients were fully continent, four with reduced pouch capacity (<300 mL) had slight incontinence and are wearing a protective pad (band-aid at the umbilicus). All patients use intermittent self-catheterization (mean catheterization frequency 6.8/day, range 6-12). Complications related to the pouch were one outlet stenosis that required revision. Postoperative pouchograms showed asymptomatic reflux in four patients. None of the patients developed metabolic acidosis or diarrhoea. The Mainz pouch III is an alternative to other types of continent urinary diversion.
Flanigan, D P; Keifer, T J; Schuler, J J; Ryan, T J; Castronuovo, J J
1983-01-01
During a 32-month period, 79 extremities in 76 children (age 1 day-13 years, mean = 31 months) were evaluated with regard to iatrogenic vascular injuries. Prospectively, 42 children were studied pre- and post-cardiac catheterization. Ten of these children sustained vascular injuries (incidence = 24%). Thirty-four additional children were referred because of 35 iatrogenic vascular injuries as a result of transfemoral cardiac catheterization (n = 20), umbilical artery catheterization (n = 10), or recent surgery (n = 5). All 45 injuries were evaluated by lower extremity segmental Doppler pressure measurements in addition to routine physical examination at the time of injury and at frequent follow-up. An ankle/brachial pressure index (ABI) less than 0.9 was considered abnormal. Selected children (ABI less than 0.9 for greater than 30 days) underwent orthoroentgenograms to assess limb growth. The average ABI immediately following injury was 0.34 +/- 0.33. Thirty-four injuries were treated nonoperatively. Twelve injuries were excluded from further study due to death (n = 7) or being lost to follow-yp (n = 5). A return of ABI to normal was seen from 1 day to 2 years in 93% of children treated with heparin (n = 14) compared to 63% of children who were simply observed (n = 8) (p less than 0.10). The initial severity of ischemia did not correlate with the subsequent rate of improvement. Only patients with absent femoral pulses were selected for operative intervention, which consisted of aortic thrombectomy (n = 2), femorofemoral bypass (n = 2), femoral artery patch angioplasty (n = 1), or femoral artery thrombectomy (n = 7) with no mortality. Nine patients had immediate return of a normal ABI after surgery. A delayed return of ABI to normal occurred in the other two. Nine per cent of surgically treated children and 23% of nonsurgically treated children developed leg length discrepancies (0.5-3.0 cm) as a result of ischemia lasting greater than 30 days. Overall, 91% of the children in this series eventually regained normal circulation following injury and no child lost a limb. This study indicates that iatrogenic pediatric vascular injuries are common and can result in significant limb growth impairment. Immediate operative intervention is highly successful when the injury is proximal to the common femoral artery bifurcation and avoids the prolonged ischemia seen with nonoperative therapy. For more distal occlusions, heparin therapy provides better results than simple observation. Although therapeutic intervention for these injuries is generally successful, a limb length discrepancy rate of 14% mandates that indications for invasive vascular monitoring and diagnostic procedures be strict. Images Fig. 2. Fig. 7. PMID:6625714
Taghavi, Sepideh; Esmaeilzadeh, Maryam; Amin, Ahmad; Naderi, Nasim; Abkenar, Hooman Bakhshandeh; Maleki, Majid; Mitra, Chitsazan
2016-01-01
Objective: A reliable and easy-to-perform method for measuring right ventricular (RV) afterload is desirable when scheduling patients with systolic heart failure to undergo heart transplantation. The present study aimed to investigate the accuracy of echocardiographically-derived pulmonary arterial elastance as a measurement of pulmonary vascular resistance by comparing it with invasive measures. Methods: Thirty-one patients with moderate to severe systolic heart failure, including 22 (71%) male patients, with a mean age of 41.16±15.9 years were enrolled in the study. Right heart catheterization and comprehensive echocardiography during the first hour after completion of cardiac catheterization were performed in all the patients. The pulmonary artery elastance was estimated using the ratio of end-systolic pressure (Pes) over the stroke volume (SV) by both cardiac catheterization [Ea (PV)-C] and echocardiography [Ea (PV)-E]. Results: The mean Ea (PV)-C and Ea (PV)-E were estimated to be 0.73±0.49 mm Hg/mL and 0.67±0.44 mm Hg/mL, respectively. There was a significant relation between Ea (PV)-E and Ea (PV)-C (r=0.897, p<0.001). Agreement between echocardiography and catheterization methods for estimating Ea (PV), investigated by the Bland-Altman method, showed a mean bias of -0.06, with 95% limits of agreement from -0.36 mm Hg/mL to 0.48 mm Hg/mL. Conclusion: Doppler echocardiography is an easy, non-invasive, and inexpensive method for measuring pulmonary arterial elastance, which provides accurate and reliable estimation of RV afterload in patients with systolic heart failure. PMID:26467379
Contrast-induced encephalopathy following cardiac catheterization.
Spina, Roberto; Simon, Neil; Markus, Romesh; Muller, David Wm; Kathir, Krishna
2017-08-01
To describe the epidemiology, pathophysiology, clinical presentation, and management of contrast-induced encephalopathy (CIE) following cardiac catheterization. CIE is an acute, reversible neurological disturbance directly attributable to the intra-arterial administration of iodinated contrast medium. The PubMed database was searched and all cases in the literature were retrieved and reviewed. 52 reports of CIE following cardiac catheterization were found. Encephalopathy, motor and sensory disturbances, vision disturbance, opthalmoplegia, aphasia, and seizures have been reported. Transient cortical blindness is the most commonly reported neurological syndrome, occurring in approximately 50% of cases. The putative mechanism involves disruption of the blood brain barrier and direct neuronal injury. Contrast-induced transient vasoconstriction has also been implicated. Symptoms typically appear within minutes to hours of contrast administration and resolve entirely within 24-48 hr. Risk factors may include hypertension, diabetes mellitus, renal impairment, the administration of large volumes of iodinated contrast, percutaneous coronary intervention or selective angiography of internal mammary grafts, and previous adverse reaction to iodinated contrast. Characteristic findings on cerebral imaging include cortical and sub-cortical contrast enhancement on computed tomography (CT). Imaging findings in CIE may mimic subarachnoid hemorrhage or cerebral ischemia; the Hounsfield scale on CT and the apparent diffusion coefficient on magnetic resonance imaging (MRI) are useful imaging tools in distinguishing these entities. In some cases, brain imaging is normal. Prognosis is excellent with supportive management alone. CIE tends to recur, although re-challenge with iodinated contrast without adverse effects has been documented. CIE is an important clinical entity to consider in the differential diagnosis of stroke following cardiac catheterization. Given that prognosis is excellent with supportive management only, physicians should be aware of it, and consider it prior to initiating thrombolysis. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Aldosterone and renin in cardiac patients referred for catheterization.
Erne, Paul; Müller, Andrea; Rossi, Gian Paolo; Seifert, Burkhardt; Stehlin, Fabrice; Redondo, Maurice; Bauer, Peter T; Kobza, Richard; Resink, Therese J; Radovanovic, Dragana
2017-06-01
Little is known regarding alterations of the renin-angiotensin system in patients referred for cardiac catheterization. Here, we measured plasma levels of active renin and aldosterone in patients referred for cardiac catheterization in order to determine the prevalence of elevated renin, aldosterone, and the aldosterone-renin ratio.A chemiluminescence assay was used to measure plasma aldosterone concentration (PAC) and active renin levels in 833 consecutive patients, after an overnight fasting and without any medication for least 12 hours. We evaluated associations of the hormonal elevations in relation to hypertension, atrial fibrillation (AF), hypertensive cardiomyopathy, coronary artery disease (CAD), valvular disease, impaired left ventricular ejection fraction (LVEF < 35%), and pulmonary hypertension (arterial pulmonary mean pressure >25 mm Hg).Hyperaldosteronism occurred in around one-third of all examined patients, without significant differences between patients with or without the named cardiac diseases. In a comparison between patients with or without any given cardiac disease condition, renin was significantly elevated in patients with either hypertension (36.4% vs 15.9%), CAD (33.9% vs 22.1%), or impaired LVEF (47.3% vs 24.8%). The angiotensin-renin ratio was elevated in AF patients and in patients with hypertensive cardiomyopathy. Patients with AF and coexisting hypertension had elevated renin more frequently than AF patients without coexisting hypertension (35.3% vs 16.5%; P = .005). Patients with persistent/permanent AF more frequently had elevated renin than patients with paroxysmal AF (34.1% vs 15.8%; P = .007).This prospective study of consecutive cardiac disease patients referred for cardiac catheterization has revealed distinct cardiac disease condition-associated differences in the frequencies of elevations in plasma renin, PAC, and the aldosterone-renin ratio.
Lauck, Sandra B; Kwon, Jae-Yung; Wood, David A; Baumbusch, Jennifer; Norekvål, Tone M; Htun, Nay; Stephenson, Leo; Webb, John G
2018-01-01
Contemporary transcatheter aortic valve implantation (TAVI) devices and approach present opportunities to review historical practices initially informed by early treatment development and cardiac surgery. The avoidance of urinary catheterization in the older TAVI population is a strategy to minimize in-hospital complications. The purpose of the study was to explore elimination-related complications following the phased implementation of a default strategy of avoiding urinary catheterization in patients undergoing transfemoral (TF) TAVI. We conducted an observational study using a retrospective chart review of patients treated between 2011 and 2013 to identify patient characteristics, peri-procedure details, in-hospital outcomes and elimination-related complications in patients who did or did not receive a peri-procedure indwelling catheter. Descriptive analyses were used to report differences between the groups; we conducted a regression analysis to explore the relationship between the practice of urinary catheterization and total procedure time. Of the 408 patients who underwent TF TAVR, 188 (46.1%) received a peri-procedure indwelling urinary catheter and 220 (53.9%) did not. There was no difference in in-hospital mortality (2.2%), disabling stroke (0.5%), or other major cardiac adverse events. The avoidance of a urinary catheter resulted in significantly lower rates of urinary tract infection requiring a new antibiotic regimen (1.4% versus 6.1%, p = 0.014), haematuria documented by medicine or nursing (3.7% versus 17.6%, p = 0.001), and the need for continuous bladder irrigation (2.7% versus 0%, p = 0.027). The avoidance of a urinary catheter may contribute to improved outcomes in patients undergoing TAVI. The intervention should be further evaluated within the broader study of minimalist TAVI.
Aiyagari, Ranjit; Rhodes, John F.; Shrader, Peter; Radtke, Wolfgang A.; Bandisode, Varsha M.; Bergersen, Lisa; Gillespie, Matthew J.; Gray, Robert G.; Guey, Lin T.; Hill, Kevin D.; Hirsch, Russel; Kim, Dennis W.; Lee, Kyong-Jin; Pelech, Andrew N.; Ringewald, Jeremy; Takao, Cheryl; Vincent, Julie A.; Ohye, Richard G.
2014-01-01
Objective To compare interstage cardiac catheterization hemodynamic and angiographic findings between shunt types for Single Ventricle Reconstruction (SVR) trial. Background The SVR trial, which randomized subjects to modified Blalock-Taussig shunt (MBTS) or right ventricle-to-pulmonary artery shunt (RVPAS) for the Norwood procedure, demonstrated RVPAS was associated with smaller pulmonary artery diameter, but superior 12-month transplant-free survival. Methods We analyzed pre-stage II catheterization data for SVR trial subjects. Hemodynamic variables and shunt and pulmonary angiography were compared between shunt types; their association with 12-month transplant-free survival was also evaluated. Results Of 549 randomized subjects, 389 underwent pre-stage II catheterization. Smaller size, lower aortic and superior vena cava saturation, and higher ventricular end-diastolic pressure (EDP) were associated with worse 12-month transplant-free survival. MBTS subjects had lower coronary perfusion pressure (27mmHg vs. 32mmHg, P<0.001) and higher Qp:Qs ratio (1.1 vs. 1.0, P=0.009). Higher Qp:Qs ratio increased the risk of death or transplant only in the RVPAS group (P=0.01). MBTS subjects had fewer shunt (14% vs. 28%, P=0.004) and severe left pulmonary artery stenoses (0.7% vs. 9.2%, P=0.003), larger mid-main branch pulmonary artery diameters and higher Nakata index (164 vs. 134, P<0.001). Conclusions Compared with RVPAS subjects, MBTS subjects had more hemodynamic abnormalities related to shunt physiology, while RVPAS subjects had more shunt or pulmonary obstruction of a severe degree, and inferior pulmonary artery growth at pre-stage II catheterization. Lower BSA, higher ventricular EDP, and lower SVC saturation were associated with worse 12-month transplant-free survival. PMID:24332668
Balaguru, Duraisamy; Rodriguez, Matthew; Leon, Stephanie; Wagner, Louis K; Beasley, Charles W; Sultzer, Andrew; Numan, Mohammed T
2018-01-01
Objectives: Direct measurement of skin dose of radiation for children using optically stimulated luminescence (OSL) technology using nanoDot® (Landauer, Glenwood, IL, USA). Background: Radiation dose is estimated as cumulative air kerma (AK) and dosearea product based on standards established for adult size patients. Body size of pediatric patients who undergo cardiac catheterization for congenital heart disease vary widely from newborn to adolescence. Direct, skindose measurement applying OSL technology may eliminate errors in the estimate. Materials and Methods: The nanoDot® (1 cm × 1 cm × flat plastic cassette) is applied to patient's skin using adhesive tape during cardiac catheterization and radiation skin doses were read within 24 hrs. nanoDot® values were compared to the currently available cumulative AK values estimated and displayed on fluoroscopy monitor. Results: A total of 12 children were studied, aged 4 months to 18 years (median 1.1 years) and weight range 5.3–86 kg (median 8.4 kg). nanoDot® readings ranged from 2.58 mGy to 424.8 mGy (median 84.1 mGy). Cumulative AK ranged from 16.2 mGy to 571.2 mGy (median 171.1 mGy). Linear correlation was noted between nanoDot® values and AK values (R2 = 0.88, R = 0.94). nanoDot® readings were approximately 65% of the estimated cumulative AK estimated using the International Electrotechnical Commission standards. Conclusions: Application of OSL technology using nanoDot® provides an alternative to directly measure fluoroscopic skin dose in children during cardiac catheterization. Our data show that the actual skin dose for children is approximately one-third lower than the AK estimated using international standards for adult size patients. PMID:29440825
Balaguru, Duraisamy; Rodriguez, Matthew; Leon, Stephanie; Wagner, Louis K; Beasley, Charles W; Sultzer, Andrew; Numan, Mohammed T
2018-01-01
Direct measurement of skin dose of radiation for children using optically stimulated luminescence (OSL) technology using nanoDot ® (Landauer, Glenwood, IL, USA). Radiation dose is estimated as cumulative air kerma (AK) and dosearea product based on standards established for adult size patients. Body size of pediatric patients who undergo cardiac catheterization for congenital heart disease vary widely from newborn to adolescence. Direct, skindose measurement applying OSL technology may eliminate errors in the estimate. The nanoDot ® (1 cm × 1 cm × flat plastic cassette) is applied to patient's skin using adhesive tape during cardiac catheterization and radiation skin doses were read within 24 hrs. nanoDot ® values were compared to the currently available cumulative AK values estimated and displayed on fluoroscopy monitor. A total of 12 children were studied, aged 4 months to 18 years (median 1.1 years) and weight range 5.3-86 kg (median 8.4 kg). nanoDot® readings ranged from 2.58 mGy to 424.8 mGy (median 84.1 mGy). Cumulative AK ranged from 16.2 mGy to 571.2 mGy (median 171.1 mGy). Linear correlation was noted between nanoDot® values and AK values ( R 2 = 0.88, R = 0.94). nanoDot® readings were approximately 65% of the estimated cumulative AK estimated using the International Electrotechnical Commission standards. Application of OSL technology using nanoDot® provides an alternative to directly measure fluoroscopic skin dose in children during cardiac catheterization. Our data show that the actual skin dose for children is approximately one-third lower than the AK estimated using international standards for adult size patients.
Sharma, S. T.; Raff, H.
2011-01-01
Context: Anomalous venous drainage can lead to false-negative inferior petrosal sinus sampling (IPSS) results. Baseline inferior petrosal sinus to peripheral (IPS/P) prolactin ratio higher than 1.8 ipsilateral to the highest ACTH ratio has been proposed to verify successful catheterization. Prolactin-normalized ACTH IPS/P ratios may differentiate Cushing's disease (CD) from ectopic ACTH syndrome (EAS). Objective: Our objective was to examine the utility of prolactin measurement during IPSS. Design, Setting, and Participants: We conducted a retrospective analysis of prolactin levels in basal and CRH-stimulated IPSS samples in ACTH-dependent Cushing's syndrome (2007–2010). Results: Twenty-five of 29 patients had a pathologically proven diagnosis (17 CD and eight EAS). IPSS results were partitioned into true positive for CD (n = 16), true negative (n = 7), false negative (n = 1), and false positive (n = 1). Prolactin IPS/P ratio suggested successful IPSS in eight of 11 with abnormal venograms. Baseline prolactin IPS/P ratio was helpful in two patients with abnormal venograms and false-negative (catheterization unsuccessful) or true-negative (catheterization successful) IPSS results; the normalized ratio correctly diagnosed their disease. Normalized ACTH IPS/P ratio was at least 1.3 in all with CD, but prolactin IPS/P ratios were misleadingly low in two. One patient with cyclic EAS had a false-positive IPSS when eucortisolemic (baseline prolactin IPS/P = 1.7; normalized ratio = 5.6). All other EAS patients had normalized ratios no higher than 0.7. Conclusion: Prolactin measurement and evaluation of the venogram can improve diagnostic accuracy when IPSS results suggest EAS but is not necessary with positive IPSS results. Confirmation of hypercortisolemia remains a prerequisite for IPSS. A normalized ratio of 0.7–1.3 was not diagnostic. PMID:22031511
Minamiguchi, Hiroki; Kawai, Nobuyuki; Sato, Morio; Ikoma, Akira; Sanda, Hiroki; Nakata, Kouhei; Tanaka, Fumihiro; Nakai, Motoki; Sonomura, Tetsuo; Murotani, Kazuhiro; Hosokawa, Seiki; Nishioku, Tadayoshi
2014-01-01
Aortography for detecting hemorrhage is limited when determining the catheter treatment strategy because the artery responsible for hemorrhage commonly overlaps organs and non-responsible arteries. Selective catheterization of untargeted arteries would result in repeated arteriography, large volumes of contrast medium, and extended time. A volume-rendered hemorrhage-responsible arteriogram created with 64 multidetector-row CT (64MDCT) during aortography (MDCTAo) can be used both for hemorrhage mapping and catheter navigation. The MDCTAo depicted hemorrhage in 61 of 71 cases of suspected acute arterial bleeding treated at our institute in the last 3 years. Complete hemostasis by embolization was achieved in all cases. The hemorrhage-responsible arteriogram was used for navigation during catheterization, thus assisting successful embolization. Hemorrhage was not visualized in the remaining 10 patients, of whom 6 had a pseudoaneurysm in a visceral artery; 1 with urinary bladder bleeding and 1 with chest wall hemorrhage had gaze tamponade; and 1 with urinary bladder hemorrhage and 1 with uterine hemorrhage had spastic arteries. Six patients with pseudoaneurysm underwent preventive embolization and the other 4 patients were managed by watchful observation. MDCTAo has the advantage of depicting the arteries responsible for hemoptysis, whether from the bronchial arteries or other systemic arteries, in a single scan. MDCTAo is particularly useful for identifying the source of acute arterial bleeding in the pancreatic arcade area, which is supplied by both the celiac and superior mesenteric arteries. In a case of pelvic hemorrhage, MDCTAo identified the responsible artery from among numerous overlapping visceral arteries that branched from the internal iliac arteries. In conclusion, a hemorrhage-responsible arteriogram created by 64MDCT immediately before catheterization is useful for deciding the catheter treatment strategy for acute arterial bleeding.
Faraoni, David; Nasr, Viviane G; DiNardo, James A
2016-01-01
This study sought to determine overall hospital cost in children with congenital heart disease (CHD) and to compare cost associated with cardiac surgical procedures, cardiac catheterizations, non-cardiac surgical procedures, and medical admissions. The 2012 Healthcare Cost and Utilization Project Kid's Inpatient Database was used to evaluate hospital cost in neonates and children with CHD undergoing cardiac surgery, cardiac catheterization, non-cardiac surgical procedures, and medical treatments. Multivariable logistic regression was applied to determine independent predictors for increased hospital cost. In 2012, total hospital cost was 28,900 M$, while hospital cost in children with CHD represented 23% of this total and accounted for only 4.4% of hospital discharges. The median cost was $51,302 ($32,088-$100,058) in children who underwent cardiac surgery, $21,920 ($13,068-$51,609) in children who underwent cardiac catheterization, $4134 ($1771-$10,253) in children who underwent non-cardiac surgery, and $23,062 ($5529-$71,887) in children admitted for medical treatments. Independent predictors for increased cost were hospital bed size <400 beds (P < 0.001), more than four procedures performed during the same hospitalization (P = 0.001), use of ECMO (P < 0.001), length of hospital stay exceeding 14 days (P < 0.001), cardiac failure (P < 0.001), sepsis (P < 0.001), acute kidney injury (P < 0.001), and neurologic (P < 0.001) and thromboembolic complications (P < 0.001). Hospital cost in children with CHD represented 23% of global cost while accounting for only 4.4% of discharges. This study identified factors associated with increased cost of cardiac surgical procedures, cardiac catheterizations, non-cardiac surgical procedures, and medical management in children with CHD.
Córdoba-Soriano, Juan Gabriel; Corbí-Pascual, Miguel; López-Neyra, Isabel; Navarro-Cuartero, Javier; Hidalgo-Olivares, Víctor; Barrionuevo-Sánchez, Maria Isabel; Prieto-Mateos, Daniel; Gutiérrez-Díez, Antonio; Gallardo-López, Arsenio; Fuentes-Manso, Raquel; Gómez-Pérez, Alberto; Lafuente-Gormaz, Carlos; Jiménez-Mazuecos, Jesús
2016-11-01
Aspirin hypersensitivity is not a rare condition among patients with acute coronary syndrome. However, despite the publication of several successful desensitization protocols, the procedure is not as widespread as expected. We present a cohort of patients with acute coronary syndrome undergoing aspirin desensitization to evaluate its short- and long-term efficacy and safety and to reinforce data from previous studies. Of 1306 patients admitted to our Coronary Care Unit between February 2011 and February 2013, 24 (1.8%) had a history of aspirin hypersensitivity. All 24 patients underwent an eight-dose aspirin desensitization protocol (0.1, 0.3, 1, 3, 10, 25, 50 and 100 mg of aspirin given by mouth every 15 minutes) after premedication with antihistamines and corticosteroids or antileucotrienes. Previously prescribed β blockers and angiotensin-converting enzyme inhibitors were not discontinued. All patients were desensitized within 72 hours of admission. Those requiring urgent catheterization (five patients with ST segment elevation myocardial infarction) were desensitized within 12 hours of catheterization and the remainder before catheterization. All patients were successfully desensitized and only one presented with an urticarial reaction. The five patients with ST segment elevation myocardial infarction were treated with abciximab until desensitization was complete. All but one patient underwent catheterization and 20 underwent percutaneous coronary intervention, most (66%) with the implantation of a bare metal stent. At follow-up (a minimum of 6-24 months), only two patients had discontinued aspirin, both due to gastrointestinal bleeding, and no hypersensitivy reaction had occurred. Aspirin desensitization is effective and safe in unstable patients with acute coronary syndrome in both the short and long term.
Hiremath, Swapnil; Akbari, Ayub; Wells, George A; Chow, Benjamin J W
2018-04-23
Contrast-induced acute kidney injury is a prominent complication following cardiac catheterization, though the risk has progressively decreased in recent times with appropriate risk stratification and use of safer contrast agents. Despite data supporting further lowering of risk with the iso-osmolar agent, iodixanol, uptake has lagged, perhaps due to increased upfront cost of this agent. We undertook an economic analysis to estimate the cost-effectiveness of a strategy utilizing iodixanol compared to using a low-osmolar contrast agent. We created a Markov model to evaluate the two strategies, and included a differential relative risk of contrast-induced acute kidney injury, based on a systematic review of the literature. Downstream clinical events, including need for dialysis and mortality, were modeled using data from existing published literature. A third-party payer perspective was utilized for the analysis and presentation of the primary economic analysis. The strategy of using iodixanol dominated in both the low-risk and high-risk base case analyses. However, the difference was quite small in the low-risk scenario (lifetime cost: C$678,034 vs. C$678,059 and life expectancy: 19.80 vs. 19.72 years). The difference was more marked (life expectancy 15.65 vs. 14.15 years and cost C$680,989 vs. C$682,023) in the high-risk case analysis. This was robust across most of the variables tested in sensitivity analyses. The use of iodixanol, compared with low-osmolar contrast agents, for cardiac catheterization, results in a small benefit clinical outcomes, and in a savings in direct healthcare costs. Overall, our analysis supports the use of iodixanol for cardiac catheterization, especially in patients at high risk of acute kidney injury.
Devroe, Sarah; Lemiere, Jurgen; Van de Velde, Marc; Gewillig, Marc; Boshoff, Derize; Rex, Steffen
2015-03-04
Xenon has minimal haemodynamic side effects when compared to volatile or intravenous anaesthetics. Moreover, in in vitro and in animal experiments, xenon has been demonstrated to convey cardio- and neuroprotective effects. Neuroprotection could be advantageous in paediatric anaesthesia as there is growing concern, based on both laboratory studies and retrospective human clinical studies, that anaesthetics may trigger an injury in the developing brain, resulting in long-lasting neurodevelopmental consequences. Furthermore, xenon-mediated neuroprotection could help to prevent emergence delirium/agitation. Altogether, the beneficial haemodynamic profile combined with its putative organ-protective properties could render xenon an attractive option for anaesthesia of children undergoing cardiac catheterization. In a phase-II, mono-centre, prospective, single-blind, randomised, controlled study, we will test the hypothesis that the administration of 50% xenon as an adjuvant to general anaesthesia with sevoflurane in children undergoing elective cardiac catheterization is safe and feasible. Secondary aims include the evaluation of haemodynamic parameters during and after the procedure, emergence characteristics, and the analysis of peri-operative neuro-cognitive function. A total of 40 children ages 4 to 12 years will be recruited and randomised into two study groups, receiving either a combination of sevoflurane and xenon or sevoflurane alone. Children undergoing diagnostic or interventional cardiac catheterization are a vulnerable patient population, one particularly at risk for intra-procedural haemodynamic instability. Xenon provides remarkable haemodynamic stability and potentially has cardio- and neuroprotective properties. Unfortunately, evidence is scarce on the use of xenon in the paediatric population. Our pilot study will therefore deliver important data required for prospective future clinical trials. EudraCT: 2014-002510-23 (5 September 2014).
Aldosterone and renin in cardiac patients referred for catheterization
Erne, Paul; Müller, Andrea; Rossi, Gian Paolo; Seifert, Burkhardt; Stehlin, Fabrice; Redondo, Maurice; Bauer, Peter T.; Kobza, Richard; Resink, Therese J.; Radovanovic, Dragana
2017-01-01
Abstract Little is known regarding alterations of the renin-angiotensin system in patients referred for cardiac catheterization. Here, we measured plasma levels of active renin and aldosterone in patients referred for cardiac catheterization in order to determine the prevalence of elevated renin, aldosterone, and the aldosterone-renin ratio. A chemiluminescence assay was used to measure plasma aldosterone concentration (PAC) and active renin levels in 833 consecutive patients, after an overnight fasting and without any medication for least 12 hours. We evaluated associations of the hormonal elevations in relation to hypertension, atrial fibrillation (AF), hypertensive cardiomyopathy, coronary artery disease (CAD), valvular disease, impaired left ventricular ejection fraction (LVEF < 35%), and pulmonary hypertension (arterial pulmonary mean pressure >25 mm Hg). Hyperaldosteronism occurred in around one-third of all examined patients, without significant differences between patients with or without the named cardiac diseases. In a comparison between patients with or without any given cardiac disease condition, renin was significantly elevated in patients with either hypertension (36.4% vs 15.9%), CAD (33.9% vs 22.1%), or impaired LVEF (47.3% vs 24.8%). The angiotensin-renin ratio was elevated in AF patients and in patients with hypertensive cardiomyopathy. Patients with AF and coexisting hypertension had elevated renin more frequently than AF patients without coexisting hypertension (35.3% vs 16.5%; P = .005). Patients with persistent/permanent AF more frequently had elevated renin than patients with paroxysmal AF (34.1% vs 15.8%; P = .007). This prospective study of consecutive cardiac disease patients referred for cardiac catheterization has revealed distinct cardiac disease condition-associated differences in the frequencies of elevations in plasma renin, PAC, and the aldosterone-renin ratio. PMID:28640140
Work up of Pediatric Urinary Tract Infection
Copp, Hillary L.; Schmidt, Bogdana
2016-01-01
Pediatric UTI costs the healthcare system upwards of 180 million dollars annually, and accounts for over 1.5 million clinician visits per year. Accurate and timely diagnosis of these infections is important for determining appropriate treatment and preventing long-term complications such as renal scarring, hypertension, and end-stage renal disease. Outside of the first 12 months, girls are more likely to be diagnosed with a UTI. About half of boys with UTI will be diagnosed within the first 12 months of life. The prevalence and incidence of pediatric UTI varies by age, race/ethnicity, sex and circumcision status. Diagnosis of UTI is made based on history and exam findings and confirmed with appropriately collected urine. If a bag specimen is negative, this can be used to rule out UTI without the need for confirmatory culture; however positive urinalysis tests from bag specimen warrant further investigation with a catheterized specimen or suprapubic aspiration. Urine culture is the gold standard for diagnosing UTI: Greater than 50,000 CFU on a catheterized specimen or suprapubic aspiration indicate presence of a UTI. Greater than 100,000 CFU on a voided specimen is considered a positive culture. There is no consensus on the need and optimal strategy for imaging in the setting of urinary tract infection in the pediatric population. Prompt recognition of UTI and antibiogram-based, empiric treatment or culture-based, targeted treatment should be initiated within 72 of presentation. PMID:26475948
Capecitabine-induced ventricular fibrillation arrest: Possible Kounis syndrome.
Kido, Kazuhiko; Adams, Val R; Morehead, Richard S; Flannery, Alexander H
2016-04-01
We report the case of capecitabine-induced ventricular fibrillation arrest, possibly secondary to type I Kounis syndrome. A 47-year-old man with a history of T3N1 moderately differentiated adenocarcinoma of the colon, status-post sigmoid resection, was started on adjuvant capecitabine approximately five months prior to presentation of cardiac arrest secondary to ventricular fibrillation. An electrocardiogram (EKG) revealed ST segment elevation on the lateral leads and the patient was taken emergently to the cardiac catheterization laboratory. The catheterization revealed no angiographically significant stenosis and coronary artery disease was ruled out. After ruling out other causes of cardiac arrest, the working diagnosis was capecitabine-induced ventricular fibrillation arrest. As such, an inflammatory work up was sent to evaluate for the possibility of a capecitabine hypersensitivity, or Kounis syndrome, and is the first documented report in the literature to do so when evaluating Kounis syndrome. Immunoglobulin E (IgE), tryptase, and C-reactive protein were normal but histamine, interleukin (IL)-6, and IL-10 were elevated. Histamine elevation supports the suspicion that our patient had type I Kounis syndrome. Naranjo adverse drug reaction probability scale indicates a probable adverse effect due to capecitabine with seven points. A case of capecitabine-induced ventricular fibrillation arrest is reported, with a potential for type 1 Kounis syndrome as an underlying pathology supported by immunologic work up. © The Author(s) 2014.
The potential for neurovascular intravenous angiography using K-edge digital subtraction angiography
NASA Astrophysics Data System (ADS)
Schültke, E.; Fiedler, S.; Kelly, M.; Griebel, R.; Juurlink, B.; LeDuc, G.; Estève, F.; Le Bas, J.-F.; Renier, M.; Nemoz, C.; Meguro, K.
2005-08-01
Background: Catheterization of small-caliber blood vessels in the central nervous system can be extremely challenging. Alternatively, intravenous (i.v.) administration of contrast agent is minimally invasive and therefore carries a much lower risk for the patient. With conventional X-ray equipment, volumes of contrast agent that could be safely administered to the patient do not allow acquisition of high-quality images after i.v. injection, because the contrast bolus is extremely diluted by passage through the heart. However, synchrotron-based digital K-edge subtraction angiography does allow acquisition of high-quality images after i.v. administration of relatively small doses of contrast agent. Materials and methods: Eight adult male New Zealand rabbits were used for our experiments. Animals were submitted to both angiography with conventional X-ray equipment and synchrotron-based digital subtraction angiography. Results: With conventional X-ray equipment, no contrast was seen in either cerebral or spinal blood vessels after i.v. injection of iodinated contrast agent. However, using K-edge digital subtraction angiography, as little as 1 ml iodinated contrast agent, when administered as i.v. bolus, yielded images of small-caliber blood vessels in the central nervous system (both brain and spinal cord). Conclusions: If it would be possible to image blood vessels of the same diameter in the central nervous system of human patients, the synchrotron-based technique could yield high-quality images at a significantly lower risk for the patient than conventional X-ray imaging. Images could be acquired where catheterization of feeding blood vessels has proven impossible.
Pannek, J; Bertschy, S
2011-10-01
A systematic literature review. To systematically assess the existing knowledge about treatment of neurogenic lower urinary tract dysfunction (NLUTD) in pregnant women with traumatic spinal cord injury (SCI), as urologic management of these patients is mandatory, but no guidelines are available. Paraplegic center in Switzerland. Studies were identified by electronic search of PubMed and MedLine. Data were pooled and analyzed quantitatively. The evidence level of all 14 reports (163 patients, 226 pregnancies) included was low. In 13 studies, information was gathered by a retrospective review of the medical records or by questionnaires. In all studies, reported data were incomplete. SCI was cervical in 34.7%, thoracic in 61.2% and lumbar in 4.1% of the pregnant women. In all 34.7% of the women used indwelling catheters, 25% performed intermittent catheterization, 11.5% used the Credé maneuver and 28.8% voided spontaneously. A total of 64% of the patients had at least one symptomatic urinary tract infection (UTI) during pregnancy. UTIs were more common in women with indwelling catheters (100%) than in those performing intermittent catheterization (38.5%), using the Credé technique (17%) or voiding spontaneously (53.3%). One study demonstrated a significant reduction in UTI during pregnancy without complications in mothers or infants. No evidence-based recommendations can be drawn from the existing literature to guide urologists in the management of NLUTD in pregnant women with SCI. The number of studies is small, and data acquisition and presentation are often inadequate. Thus, further research is urgently needed.
Alavinia, Seyed Mohammad; Omidvar, Maryam; Farahani, Farnoosh; Bayley, Mark; Zee, Joana; Craven, Beverley Catharine
2017-11-01
To reduce the incidence of Urinary Tract Infection (UTI) in subacute SCI individuals admitted for tertiary inpatient rehabilitation. A quality improvement team was assembled to improve UTI prevention/diagnosis. To plan data collection, UTI-related factors were mapped in an Ishikawa (fishbone) driver diagram. Data including patient demographics, presence and frequency of signs and/or symptoms of UTI and antibiotic initiation from August to December 2015 were recorded. Sensitivity, Specificity, Positive and Negative Predictive Values (PPV, NPV), and Likelihood Ratios (LR) were calculated for each sign and symptom. Tertiary SCI Rehabilitation Results: Among 55 inpatients with subacute SCI who had signs/symptoms prompting urine culture and sensitivity (C&S), 32 (58.18%) were diagnosed with a UTI. The most frequent symptoms were foul smelling urine (41%), change in urine color (31%), and incontinence (25%), and the most common sign was fever (34%). Most UTIs (81%) occurred among individuals using Clean Intermittent Catheterization (CIC), with 46% of catheterizations performed by nurses. Foul smelling urine had the highest sensitivity (0.50, 95% CI: 0.31-0.69), and new incontinence had the highest specificity (0.88, 95% CI: 0.69-0.97) for UTI diagnosis. The highest PPV belonged to the cloudy urine (0.71, 95% CI: 0.42-0.92). The combination of cloudy and foul smelling urine increased the PPV to 78% (95% CI: (0.40-0.97). The concurrent presence of cloudy and foul smelling urine is predicted of UTI diagnosis inpatients tertiary setting. SCI inpatients are susceptible to UTI when learning CIC technique from nurses.
1993-11-01
Despite the emergence of several alternative angiographic imaging techniques (i.e., magnetic resonance imaging, computed tomography, and ultrasound angiography), x-ray angiography remains the predominant vascular imaging modality, generating over $4 billion in revenue a year in U.S. hospitals. In this issue, we provide a brief overview of the various angiographic imaging techniques, comparing them with x-ray angiography, and discuss the clinical aspects of x-ray vascular imaging, including catheterization and clinical applications. Clinical, cost, usage, and legal issues related to contrast media are discussed in "Contrast Media: Ionic versus Nonionic and Low-osmolality Agents." We also provide a technical overview and selection guidance for a basic x-ray angiography imaging system, including the gantry and table system, x-ray generator, x-ray tube, image intensifier, video camera and display monitors, image-recording devices, and digital acquisition and processing systems. This issue also contains our Evaluation of the GE Advantx L/C cardiac angiography system and the GE Advantx AFM general-purpose angiography system; the AFM can be used for peripheral, pulmonary, and cerebral vascular studied, among others, and can also be configured for cardiac angiography. Many features of the Advantx L/C system, including generator characteristics and ease of use, also apply to the Advantx AFM as configured for cardiac angiography. Our ratings are based on the systems' ability to provide the best possible image quality for diagnosis and therapy while minimizing patient and personnel exposure to radiation, as well as its ability to minimize operator effort and inconvenience. Both units are rated Acceptable. In the Guidance Section, "Radiation Safety and Protection," we discuss the importance of keeping patient and personnel exposures to radiation as low as reasonably possible, especially in procedures such as cardiac catheterization, angiographic imaging for special procedures, and interventional radiology, which produce among the highest radiation exposure of all x-ray imaging techniques. We also provide recommendations for minimizing personnel and patient exposures to radiation. For more information about x-ray angiography systems and similar devices, as well as for additional perspectives on which we based this study, see the following Health Devices Evaluations: "Mobile C-arm Units" (19[8], August 1990) and "Noninvasive Electronic Quality Control Devices for X-ray Generator Testing" (21[6-7], June-July 1992).(ABSTRACT TRUNCATED AT 400 WORDS)
Extradural and subarachnoid catheterization using the Seldinger technique.
Delhaas, E M
1996-01-01
The Seldinger technique was developed using a plastic introducer through which introduction and manipulations of a silicone spinal catheter, an extradural stimulation lead or a small diameter fibreoptic scope are possible without the risk of damage to the vulnerable devices. It is not intended as a replacement of the standard technique of introducing a spinal catheter through a Tuohy needle in general anaesthetic practice. Silicone spinal catheters and stimulation leads are used for long-term therapy in intractable chronic pain and spasticity. A fibreoptic scope is used for endoscopic examination of the subarachnoid or extradural space. Using a standard Tuohy needle the soft silicone extradural lead can be damaged easily by manipulations during insertion. For this reason the manufacturer modified the Tuohy needle for extradural silicone lead introduction. The disadvantages of this modified Tuohy needle are: first, difficulty in localization of the extradural space, second, the needle is unsuitable for a subarachnoid catheter or introduction of a fibreoptic scope. The Seldinger technique was performed 25 times in 18 patients, introducing a spinal silicone catheter (n = 14), an extradural silicone stimulation lead (n = 2) or a small diameter fibreoptic endoscope (n = 9). Paraesthesiae caused by neural irritation occurred in awake patients. This did not differ from the technique using a Tuohy needle only. Neural damage or trauma did not occur with the Seldinger technique. The incidence of post-spinal headache was the same for both techniques. No further complications were noted.
Kerkeni, W; Chahwan, C; Lenormand, C; Dubray, B; Benyoucef, A; Pfister, C
2014-03-01
Brachytherapy is a possible treatment for localized low risk prostate cancer. Although this option is minimally invasive, some side effects may occur. Acute retention of urine (ARU) has been observed in 5% to 22% of cases and can be prevented in most cases by alpha-blocker treatment. Several alternatives have been reported in the literature for the management of ARU following brachytherapy: prolonged suprapubic catheterization, transurethral resection of the prostate and also intermittent self-catheterization. The authors report an original endoscopic approach, using urethral endoprosthesis, with a satisfactory voiding status. Copyright © 2013. Published by Elsevier Masson SAS.
Interventional-Cardiovascular MR: Role of the Interventional MR Technologist
Mazal, Jonathan R; Rogers, Toby; Schenke, William H; Faranesh, Anthony Z; Hansen, Michael; O’Brien, Kendall; Ratnayaka, Kanishka; Lederman, Robert J
2016-01-01
Background Interventional-cardiovascular magnetic resonance (iCMR) is a promising clinical tool for adults and children who need a comprehensive hemodynamic catheterization of the heart. Magnetic resonance (MR) imaging-guided cardiac catheterization offers radiation-free examination with increased soft tissue contrast and unconstrained imaging planes for catheter guidance. The interventional MR technologist plays an important role in the care of patients undergoing such procedures. It is therefore helpful for technologists to under-stand the unique iCMR preprocedural preparation, procedural and imaging workflows, and management of emergencies. The authors report their team’s experience from the National Institutes of Health Clinical Center and a collaborating pediatric site. PMID:26721838
A bulbar artery pseudoaneurysm following traumatic urethral catheterization.
Bettez, Mathieu; Aubé, Melanie; Sherbiny, Mohamed El; Cabrera, Tatiana; Jednak, Roman
2017-01-01
Traumatic urethral catheterization may result in a number of serious complications. A rare occurrence is the development of a urethral pseudoaneurysm. We report the case of a 13-year-old male who required placement of a Foley catheter for an orthopedic surgical procedure. The Foley was misplaced in the bulbourethra, resulting in the development of a bulbar artery pseudoaneurysm. Profuse bleeding via the urethra was noted after removal of the catheter, and the patient experienced severe intermittent hematuria during the postoperative period. Cystoscopy revealed a pulsatile mass within the bulbourethra. Angiography confirmed a bulbar artery pseudoaneurysm, which was successfully embolized with resolution of bleeding.
Mobile-Based Video Learning Outcomes in Clinical Nursing Skill Education
Lee, Nam-Ju; Chae, Sun-Mi; Kim, Haejin; Lee, Ji-Hye; Min, Hyojin Jennifer; Park, Da-Eun
2016-01-01
Mobile devices are a regular part of daily life among the younger generations. Thus, now is the time to apply mobile device use to nursing education. The purpose of this study was to identify the effects of a mobile-based video clip on learning motivation, competence, and class satisfaction in nursing students using a randomized controlled trial with a pretest and posttest design. A total of 71 nursing students participated in this study: 36 in the intervention group and 35 in the control group. A video clip of how to perform a urinary catheterization was developed, and the intervention group was able to download it to their own mobile devices for unlimited viewing throughout 1 week. All of the students participated in a practice laboratory to learn urinary catheterization and were blindly tested for their performance skills after participation in the laboratory. The intervention group showed significantly higher levels of learning motivation and class satisfaction than did the control. Of the fundamental nursing competencies, the intervention group was more confident in practicing catheterization than their counterparts. Our findings suggest that video clips using mobile devices are useful tools that educate student nurses on relevant clinical skills and improve learning outcomes. PMID:26389858
Wen, Jun; Duan, Chuan-Zhi; Huang, Li-Jing; Zhang, Xin; He, Xu-Ying; Li, Xi-Feng
2015-09-01
Transvenous embolization is the treatment of choice for cavernous sinus dural arteriovenous fistulas (csDAVFs) despite occasional difficulty in transvenous catheterization. We reported our experience in the treatment of csDAVFs by transarterial Onyx embolization in patients who had failed transvenous catheterization. We reviewed the clinical and radiographic records of csDAVFs patients receiving transarterial Onyx embolization after failed transvenous Onyx embolization at our institution over a period of 31 months. Success was defined as complete or near complete occlusion upon angiographic examination. In seven cases, the microcatheter failed to reach the cavernous sinus; in the remaining case, the internal jugular vein was occlusive. Eight sessions of the embolization and catheterization procedures via the arterial routes were conducted. Among them, five cases via the middle meningeal artery and the other three via the accessory meningeal artery. Angiography, immediately after embolization, revealed complete occlusion in seven cases (87.5 %) and partial occlusion in the remaining case. Angiographic follow-up (range, 6-10 months) showed that all patients achieved complete embolization. In cases where transvenous embolization of the cavernous sinus is difficult, transarterial embolization of the fistulas offers a safe and effective alternative.
Kotoda, Atsushi; Akimoto, Tetsu; Sugase, Taro; Yamamoto, Hisashi; Kusano, Eiji
2013-01-01
Central venous stenosis (CVS) is a serious complication for chronic hemodialysis (HD) patients. Previous reports of CVS have focused on prior central venous catheterization, because of the higher prevalence and potential for prevention of such an event. However, recent studies have demonstrated that CVS may also develop without a history of central venous catheterization. Although information about the etiological backgrounds regarding the development of CVS without previous central venous catheterization have gradually accumulated, the clinical impact of the chronic compression of the central venous system by the surrounding structures, which may likely determine the central venous susceptibility to CVS, remains poorly understood. This study proposes the hypothesis that the combination of chronic venous compression at the level of thoracic outlet characterized by the natural physique and elevated venous flow induced by the creation of vascular access should be evaluated as a potential factor for the development of CVS, since they may accelerate the development of venous stenosis, presumably through the stimulation of intimal hyperplasia, and thereby the subclavian venous susceptibility to CVS should be determined. Copyright © 2012 Elsevier Ltd. All rights reserved.
Mujtaba, Alhasan; Taher, Mohammed A; Hazza, Mazin A; Al-Rubaye, Hassan M; Kata, Asaad H; AbdulWahab, Hamid; AbdulBari, AbdulAmeer; AlRubay, Hayder K
2018-05-21
Patients undergoing coronary catheterization are at high risk of developing contrast-induced nephropathy (CIN) acute kidney injury (AKI). Several approaches have been supposed to limit such an effect but with mixed results or non-practical methods. Spironolactone is supposed to be effective as a nephroprotective agent in animal studies. This study will try to measure the effect of spironolactone on the incidence of CIN-AKI in patients undergoing coronary catheterization (angiography angioplasty). This study is a single-center, investigator-driven, double-blinded randomized controlled study in Iraq-Basra. More than 400 patients admitted for coronary angio unit in our center will be allocated in a 1:1 ratio to receive either spironolactone 200 mg single dose or placebo in addition to their usual premedication. Primary end point will be CIN defined as more than 25% or 0.3 mg/dl elevation in serum creatinine (S.Cr.) from baseline during the first 2-3 days after the procedure. We hope to identify or answer an important question regarding CIN in such high-risk patients. ClinicalTrials.gov Identifier, NCT03329443.
Lee, Nam-Ju; Chae, Sun-Mi; Kim, Haejin; Lee, Ji-Hye; Min, Hyojin Jennifer; Park, Da-Eun
2016-01-01
Mobile devices are a regular part of daily life among the younger generations. Thus, now is the time to apply mobile device use to nursing education. The purpose of this study was to identify the effects of a mobile-based video clip on learning motivation, competence, and class satisfaction in nursing students using a randomized controlled trial with a pretest and posttest design. A total of 71 nursing students participated in this study: 36 in the intervention group and 35 in the control group. A video clip of how to perform a urinary catheterization was developed, and the intervention group was able to download it to their own mobile devices for unlimited viewing throughout 1 week. All of the students participated in a practice laboratory to learn urinary catheterization and were blindly tested for their performance skills after participation in the laboratory. The intervention group showed significantly higher levels of learning motivation and class satisfaction than did the control. Of the fundamental nursing competencies, the intervention group was more confident in practicing catheterization than their counterparts. Our findings suggest that video clips using mobile devices are useful tools that educate student nurses on relevant clinical skills and improve learning outcomes.
Plehn, Gunnar; Butz, Thomas; Maagh, Petra; Meissner, Axel
2017-01-18
Due to a continuing age shift in the German society hospital providers are concerned about the additional costs associated with the treatment of elderly patients. It is not clear if cardiac catheterization in aged patients leads to higher resource utilization and if DRG-revenues do compensate for this factor. Procedure-related and administrative data of all patients who underwent cardiac catheterization at a tertiary heart center between 2007 and 2011 were collected and analyzed. Then a profitability analysis was performed by comparing the case related variable costs with the Diagnosis-related group (DRG) per case revenues. A particular emphasis was placed on a comparative analysis of identical clusters of procedures. The most frequently performed catheterization procedure (n = 1800) was associated with significantly higher material expenditure in very old patients (178 ± 48 €) than in old (171 ± 28; p = 0.001) and young patients (172 ± 39; p = 0.046). Furthermore, radiation time and the length of hospital stay were increased in very old patients (3.5 ± 3.8 min and 6.2 ± 4.8 days) compared to old (2.7 ± 2.8 min and 4.6 ± 3.8 days; p < 0.001) and young patients (2.5 ± 2.5 min and 4.5 ± 3.9 days; p < 0.001). Due to higher DRG revenues very old patients achieved higher absolute contribution margins (2065 ± 1033 €) than old (1804 ± 1902 €; p < 0.001) and young patients (1771 ± 902 €; p < 0.001). However, the contribution margins per day were significantly smaller (440 ± 226 €) than those in old (488 ± 234 €; p = 0.001) and young patients (484 ± 206 €; p = 0.001). Catheterization of very old patients is related to lower contribution margins per day despite higher material and time expenditures. Since efforts to reduce the length of hospital stay of these patients are limited, this may result in a competitive disadvantage of hospitals which are more affected by the demographic change.
NASA Technical Reports Server (NTRS)
Katkov, V. Y.; Chesturkhin, V. V.; Zybin, O. K.; Sukhotskiy, S. S.; Abrosimov, S. V.; Utkin, V. N.
1981-01-01
The right parts of the heart and the radial artery were catheterized in healthy male volunteers before and 5 days after strict bedrest in antiorthostatic position of the body (-4.5 deg). After immobilization, most values of central circulation showed no essential changes; the only exceptions were indicates characterizing the inotropic myocardial condition. A shift in the direction of acidosis of a mixed character was noted in mixed venous blood, the beta lipoprotein content increased. A decrease in the arteriovenous difference in oxygen was encountered in blood draining from the heart (from the coronary sinus).
Surgical Management of Neurogenic Lower Urinary Tract Dysfunction.
Gor, Ronak A; Elliott, Sean P
2017-08-01
Surgery for patients with neurogenic urinary tract dysfunction (nLUTD) is indicated when medical therapy fails, to correct conditions affecting patient safety, or when surgery can enhance the quality of life better than nonoperative management. Examples include failure of maximal medical therapy, inability to perform or aversion to clean intermittent catheterization, refractory incontinence, and complications from chronic, indwelling catheters. Adults with nLUTD have competing risk factors, including previous operations, obesity, poor nutritional status, complex living arrangements, impaired dexterity/paralysis, and impaired executive and cognitive function. Complications are common in this subgroup of patients requiring enduring commitments from surgeons, patients, and their caretakers. Copyright © 2017 Elsevier Inc. All rights reserved.
Valle, Ramiro Del; Zenteno, Marco; Jaramillo, José; Lee, Angel; De Anda, Salvador
2008-12-01
The cumulative experience worldwide indicates complete radiosurgical obliteration rates of brain arteriovenous malformations (AVMs) ranging from 35 to 90%. The purpose of this study was to propose a strategy to increase the obliteration rate for AVMs through the dynamic definition of the key target volume (KTV). A prospective series of patients harboring an AVM was assessed using digital subtraction angiography in which a digital counter was used to measure the several stages of the frame-by-frame circulation time. All the patients were analyzed using dynamic measurement planning to define the KTV, corresponding to the volume of the shunt with the least vascular resistance and the earliest venous drainage. All patients underwent catheter-based angiography, a subgroup was additionally assessed by means of a superselective catheterization, and among these a further subgroup received embolization. The shunts were also categorized according to their angioarchitectural type: fistulous, plexiform, or mixed. The authors applied the radiosurgery-based grading system (RBGS) as well to find a correlation with the obliteration rate. This series includes 44 patients treated by radiosurgery; global angiography was performed for all patients, including dynamic measurement planning. Eighty-four percent of them underwent superselective catheterization, and 50% of the total population underwent embolization. In the embolized arm of the study, the pretreatment volume was up to 120 ml. In patients with a single treatment, the mean volume was 8.5 ml, and the median volume was 6.95 +/- 4.56 ml (mean +/- standard deviation), with a KTV of up to 15 ml. For prospectively staged radiosurgery, the mean KTV was 28 ml. The marginal radiation dose was 18-22 Gy, with a mean of dose 20 Gy. The mean RBGS score was 1.70. The overall obliteration rate was 91%, including the repeated radiosurgery group (4 patients), in which 100% showed complete obliteration. The overall permanent deficit was 2 of 44 patients, 1 in each group. Dynamic definition of the KTV might increase the obliteration rate, even in complex AVMs, allowing the treatment of smaller volumes off the recruitment vessels (pseudonidus). By using this technique, the authors avoided double-blind treatment, where the neurosurgeon does not know precisely which type of lesion he or she is irradiating and the interventionalist does not know why and what he or she is embolizing.
Totally Endoscopic Coronary Artery Bypass for Anomalous Origin of Right Coronary Artery.
Kuo, Chia-Cheng; Hsing, Chung-Hsi; Cheng, Bor-Chih
2017-01-01
Anomalous origin of the right coronary artery (ARCA) from the left Valsalva sinus is a rare but known cause of sudden cardiac death. Surgical revascularization techniques include coronary artery bypass grafting, unroofing, and reimplantation. We report 4 patients who underwent robot-assisted totally endoscopic coronary artery bypass (TECAB) for ARCA as an alternative surgical option. In 3 patients, a single aortocoronary saphenous vein bypass was performed, and in 1 patient the right internal mammary artery was used. All grafts are patent as shown by computed tomographic angiography or cardiac catheterization. We claim that totally endoscopic coronary artery bypass is feasible and safe for anomalous origin of the right coronary artery. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
A short history of the Foley catheter: from handmade instrument to infection-prevention device.
Carr, H A
2000-02-01
Although it is one of the most frequently utilized devices in the hospitalized patient, the Foley catheter has often been taken for granted. This lack of attention is unfortunate, as the Foley catheter remains one of the primary sources of hospital-acquired infections, which increase morbidity, mortality, and the financial burden on the healthcare system. Although education on the appropriate techniques, proper use, and early removal of Foley catheters is important, such measures unfortunately result in transient benefits. Current technologic advancements have moved the coating technology to a state where bacterial adhesion and migration can be limited and the frequency of catheter-associated urinary tract infections can be reduced. Future technological advances in the Foley catheter will help provide better care and comfort for the catheterized patient.
The new era of cardiac surgery: hybrid therapy for cardiovascular disease.
Solenkova, Natalia V; Umakanthan, Ramanan; Leacche, Marzia; Zhao, David X; Byrne, John G
2010-11-01
Surgical therapy for cardiovascular disease carries excellent long-term outcomes but it is relatively invasive. With the development of new devices and techniques, modern cardiovascular surgery is trending toward less invasive approaches, especially for patients at high risk for traditional open heart surgery. A hybrid strategy combines traditional surgical treatments performed in the operating room with treatments traditionally available only in the catheterization laboratory with the goal of offering patients the best available therapy for any set of cardiovascular diseases. Examples of hybrid procedures include hybrid coronary artery bypass grafting, hybrid valve surgery and percutaneous coronary intervention, hybrid endocardial and epicardial atrial fibrillation procedures, and hybrid coronary artery bypass grafting/carotid artery stenting. This multidisciplinary approach requires strong collaboration between cardiac surgeons, vascular surgeons, and interventional cardiologists to obtain optimal patient outcomes.
Noji, S; Kitamura, N; Yamaguchi, A; Otaki, M; Miki, T; Tamura, H
1991-08-01
We present a surgical case of 41-year-old woman with Scimitar syndrome. Preoperative catheterization showed azygos connection and L-R shunt ratio of 45% without intracardiac malformations. To our knowledge, this combination has not been previously reported. At operation the right single pulmonary vein was found and drained into the inferior vena cava below the diaphragm. Because of counter clockwise rotation of the heart the distance of the scimitar vein and the left atrium was too long for direct anastomosis, a polytetrafluoroethylene tube (10 mm in diameter) was utilized for an extracardiac conduit using cardiopulmonary bypass. Postoperative course was uneventful. We conclude that this technique is effective for this syndrome with a large amount of L-R shunt and a sufficient patency is expected.
Gomez, Jorge E; Gentile, Jorge I
2011-01-01
Two children were sent to the catheterization laboratory for transcatheter closure of patent ductus arteriosus (PDA). During the intervention, cineangiogram revealed associated aberrant right subclavian artery (ARSA). Both patients had left-sided aortic arch. The first patient was sent to surgery after one unsuccessful attempt to close the PDA due to the proximity of the ARSA and also because of other concomitant cardiac lesions. We successfully treated the second patient by closing the PDA with a Nit-Occlud® PDA occlusion device (Pfm Medical, Carlsbad, California). Similar mirror cases of PDA closure with aberrant left subclavian artery and right aortic arch have been reported. Anatomic features, as well as the technique and management of the procedure, are discussed here.
Cystoscopic temporary ureteral catheterization during radical vaginal and abdominal trachelectomy.
Abu-Rustum, Nadeem R; Sonoda, Yukio; Black, Destin; Chi, Dennis S; Barakat, Richard R
2006-11-01
To describe the role of temporary retrograde ureteral catheterization at the time of fertility-sparing radical vaginal or abdominal trachelectomy in women with early-stage cervical cancer. We analyzed a prospectively maintained database of all patients with cervical cancer who were explored for radical vaginal or abdominal trachelectomy at our institution. Cystourethroscopy and ureteral catheterization were performed prior to the vaginal or abdominal operation in all patients, except two pediatric ones. Temporary bilateral retrograde ureteral catheters were planned for all patients as part of our routine procedure to facilitate identification of the distal ureters. 5Fr whistle-tip or open-ended catheters were used and usually advanced to approximately 20 cm. Catheters were removed at the end of the operation in all cases. All catheters were inserted by a gynecologic oncology fellow or attending. Between 11/01 and 12/05, 40 patients were taken to the operating room for planned fertility-sparing radical vaginal or abdominal trachelectomy. We previously reported on two pediatric patients; they are excluded from this report. The median age for adult patients was 32 years (mean, 31.6; range, 23-40). International Federation of Gynecology and Obstetrics (FIGO) stage included IB1 (26), IA2 (6), and IA1 with lymphovascular invasion (6). Thirty-four patients underwent radical vaginal trachelectomy and four underwent a radical abdominal trachelectomy. Two (5%) of 38 patients required immediate completion radical hysterectomy due to extensive endocervical disease (one in the vaginal group and one in the abdominal group). Bilateral ureteral catheters were inserted successfully in 37 (97%) of 38 patients and facilitated identification of the distal ureter during the dissection. In one case, the right ureteral orifice could not be successfully catheterized, and the case was completed with unilateral catheterization. The estimated time to perform this part of the operation was approximately 15-20 min. Twenty-eight patients (74%) had 5Fr whistle-tip ureteral catheters inserted, and 10 had open-ended catheters inserted. There were no intraoperative complications. Median hospital stay was 3 days (range, 3-7). Hematuria, evident in the drainage bag attached to the Foley catheter, usually resolved in 24-48 h. Two (20%) of 10 patients who had open-ended catheters inserted developed a transient rise in postoperative creatinine (1.7 and 3.5 mg/dl, respectively) compared to 0/28 patients who had whistle-tip catheters placed (P<0.001). Both were attributed to postoperative distal ureteral edema, and only one patient required reinsertion of temporary ureteral stents. No patient developed long-term urinary complications or fistulae. Cystourethroscopy and bilateral retrograde ureteral catheterization by gynecologic oncologists is a simple and quick procedure that may facilitate identifying the distal ureter during radical vaginal or abdominal trachelectomy. We favor using 5Fr whistle-tip catheters as they may be associated with less ureteral mucosal trauma and subsequent postoperative edema. The skills needed for this procedure should be available to fellows in gynecologic oncology training.
Strategic groups and performance in the nursing home industry: a reexamination.
Marlin, D; Sun, M; Huonker, J W
1999-06-01
This study further examines the relationship between strategic group membership and performance in the nursing home industry. The results indicate seven strategic groups in the industry with significant between-group differences in operating margin, average profit per patient day, catheterization rate, health deficiencies, life and safety deficiencies, and efficiency in the provision of services. The authors did not, however, find significant between-group differences in pressure sore rate, the use of restraints, or in the percentage of patients with significant unplanned weight changes. The group with the highest private-pay utilization combined with high Medicare utilization generally performed the best along all indicators. Results also suggest that strategic group membership and rural/urban location have a greater impact on performance than do ownership, chain membership, or possession of a dedicated specialty care unit.
Celiac Injury Due to Arcuate Ligament: An Endovascular Approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zini, Chiara, E-mail: zini.chiara@gmail.com; Corona, Mario, E-mail: mario.corona@uniroma.it; Boatta, Emanuele, E-mail: emanuele.boatta@yahoo.it
2013-06-15
Celiac trunk injures are rare events, with high mortality rates and difficult management. Endovascular treatment may be considered to avoid bleeding. We report a case of severe bleeding in a 37-year-old man resulting from celiac trunk stretching after a motorcycle crash. Because direct celiac trunk catheterization was not possible, a retrograde catheterization of the common hepatic artery was performed via the superior mesenteric artery. Two vascular plugs (type IV) were released, and the exclusion of the celiac trunk origin was completed with the deployment of an aortic cuff. The patient's clinical condition immediately improved, and after 6 months' follow-up, imagingmore » confirmed the complete exclusion of the celiac trunk.« less
Kim, Jeong-Eun; Jeon, Joon-Pyo; Kim, Yongsuk; Jeong, Su Ah
2014-01-01
A 23-year-old male underwent a left internal jugular vein catheterization during extended surgery for treatment of multiple fractures due to a traffic accident. Although the catheterization was performed under ultrasound (US) guidance, iatrogenic perforation of the central vein and pleura occurred. The catheter was removed, and the perforated site was addressed under thoracoscopy rather than an open thoracotomy. This case suggests that using US does not completely guarantee a complication-free outcome, and that catheter placement should be carefully confirmed. In addition, this case suggests that thoracoscopy may be an ideal method of resolving a perforation of the central vein and pleura. PMID:24851167
Barik, Ramachandra
2017-01-01
The clinical diagnosis of double chamber right ventricle (DCRV) is not straightforward. Clinical history, clinical examination, 12-lead electrocardiogram, chest X-ray, and Echocardiography (echo) contribute to morphological diagnosis. Cardiac catheterization is essential for hemodynamic evaluation. A thorough presurgical workup helps the cardiac surgeon to choose the appropriate surgical approach and timing of surgery in an individual case. We present a case of a DCRV who presented to us in the fifth decade of life. Echo confirmed the morphological diagnosis and cardiac catheterization complemented the exact pull back gradient across the obstruction in the right ventricle. This patient was suggested muscle bundle resection and ventricular septal defect closure using right atrial approach.
Dyer, Karrie; Lanning, Craig; Das, Bibhuti; Lee, Po-Feng; Ivy, D. Dunbar; Valdes-Cruz, Lilliam; Shandas, Robin
2007-01-01
Background We have shown previously that input impedance of the pulmonary vasculature provides a comprehensive characterization of right ventricular afterload by including compliance. However, impedance-based compliance assessment requires invasive measurements. Here, we develop and validate a noninvasive method to measure pulmonary artery (PA) compliance using ultrasound color M-mode (CMM) Doppler tissue imaging (DTI). Methods Dynamic compliance (Cdyn) of the PA was obtained from CMM DTI and continuous wave Doppler measurement of the tricuspid regurgitant velocity. Cdyn was calculated as: [(Ds − Dd)/(Dd × Ps)] × 104; where Ds = systolic diameter, Dd = diastolic diameter, and Ps = systolic pressure. The method was validated both in vitro and in 13 patients in the catheterization laboratory, and then tested on 27 pediatric patients with pulmonary hypertension, with comparison with 10 age-matched control subjects. Cdyn was also measured in an additional 13 patients undergoing reactivity studies. Results Instantaneous diameter measured using CMM DTI agreed well with intravascular ultrasound measurements in the in vitro models. Clinically, Cdyn calculated by CMM DTI agreed with Cdyn calculated using invasive techniques (23.4 ± 16.8 vs 29.1 ± 20.6%/100 mm Hg; P = not significant). Patients with pulmonary hypertension had significantly lower peak wall velocity values and lower Cdyn values than control subjects (P < .01). Cdyn values followed an exponentially decaying relationship with PA pressure, indicating the nonlinear stress–strain behavior of these arteries. Reactivity in Cdyn agreed with reactivity measured using impedance techniques. Conclusion The Cdyn method provides a noninvasive means of assessing PA compliance and should be useful as an additional measure of vascular reactivity subsequent to pulmonary vascular resistance in patients with pulmonary hypertension. PMID:16581479
Dyer, Karrie; Lanning, Craig; Das, Bibhuti; Lee, Po-Feng; Ivy, D Dunbar; Valdes-Cruz, Lilliam; Shandas, Robin
2006-04-01
We have shown previously that input impedance of the pulmonary vasculature provides a comprehensive characterization of right ventricular afterload by including compliance. However, impedance-based compliance assessment requires invasive measurements. Here, we develop and validate a noninvasive method to measure pulmonary artery (PA) compliance using ultrasound color M-mode (CMM) Doppler tissue imaging (DTI). Dynamic compliance (C(dyn)) of the PA was obtained from CMM DTI and continuous wave Doppler measurement of the tricuspid regurgitant velocity. C(dyn) was calculated as: [(D(s) - D(d))/(D(d) x P(s))] x 10(4); where D(s) = systolic diameter, D(d) = diastolic diameter, and P(s) = systolic pressure. The method was validated both in vitro and in 13 patients in the catheterization laboratory, and then tested on 27 pediatric patients with pulmonary hypertension, with comparison with 10 age-matched control subjects. C(dyn) was also measured in an additional 13 patients undergoing reactivity studies. Instantaneous diameter measured using CMM DTI agreed well with intravascular ultrasound measurements in the in vitro models. Clinically, C(dyn) calculated by CMM DTI agreed with C(dyn) calculated using invasive techniques (23.4 +/- 16.8 vs 29.1 +/- 20.6%/100 mm Hg; P = not significant). Patients with pulmonary hypertension had significantly lower peak wall velocity values and lower C(dyn) values than control subjects (P < .01). C(dyn) values followed an exponentially decaying relationship with PA pressure, indicating the nonlinear stress-strain behavior of these arteries. Reactivity in C(dyn) agreed with reactivity measured using impedance techniques. The C(dyn) method provides a noninvasive means of assessing PA compliance and should be useful as an additional measure of vascular reactivity subsequent to pulmonary vascular resistance in patients with pulmonary hypertension.
[Bioresorbable vascular scaffolds: clinical experience of the Emilia-Romagna Region, Italy].
Menozzi, Alberto; Campo, Gianluca Calogero; Guiducci, Vincenzo; Dall'Ara, Gianni; Santarelli, Andrea; Sbarzaglia, Paolo; Balducelli, Marco; Magnavacchi, Paolo; Sgura, Fabio; Losi, Luciano; Vignali, Luigi; Casella, Gianni; Steffanon, Luigi; Tarantino, Fabio; Saia, Francesco
2017-02-01
The bioresorbable vascular scaffold (BRS) technology constitutes the new revolution of the coronary artery disease interventional treatment. Currently, three distinct types of BRSs are available but only one, the Absorb BVS, was on the market in 2013 when the Regional Commission for Medical Devices and the Cardiology and Cardiac Surgery Commission of the Emilia-Romagna Region drew up a technical and scientific essay to provide guidance for the introduction of BRS in public and affiliated health facilities. Five preferential indications were given for use: long coronary lesions (>28 mm), ostial lesions (left main stem excluded), complete revascularization in patients aged <50 years, diffuse disease (>40 mm) or involving the mid/distal left anterior descending (LAD) branch in patients <70 years, spontaneous coronary artery dissection. This survey analyzed data from all the catheterization laboratories in the Emilia-Romagna Region, merged in a unified database. In a 3-year study period, 546 BRS were implanted in 328 patients, corresponding to 1.5% of the drug-eluting stents (DES) used, with a trend towards a progressive increase over time. Initial indications were followed in 200/328 (61.0%) patients (about one third fitting more indications), mainly for treatment of long lesions in vessels >2.5 mm (67%), young patients (31.5%) and mid/distal LAD (28%). In 22.6% of cases the clinical scenario was a ST-segment elevation myocardial infarction, in 39.3% a non-ST-segment elevation acute coronary syndrome. Intracoronary imaging was infrequently used (intravascular ultrasound in 24.7% of cases). In 85 patients (25.9%) a hybrid procedure (BVS/DES) was performed. BRS use has resulted lower than expected, with discrete variability among centers, but according to the initial indications of the Emilia-Romagna Region in the majority of cases. The underuse might have been due to operators' caution in their initial experience. However, the increasing trend may reveal a greater confidence in the implantation technique and the whole amount of safety and efficacy data.
Han, Ya-ling; Liang, Zhuo; Yao, Tian-ming; Sun, Jing-yang; Liang, Ming; Huo, Yu; Wang, Geng; Wang, Xiao-zeng; Liang, Yan-chun; Meng, Wei-hong
2012-03-01
Natural disasters have been frequent in recent years. Effective treatment of patients with cardiovascular disease following natural disasters is an unsolved problem. We aimed to develop a novel miniature mobile cardiac catheterization laboratory (Mini Mobile Cath Lab) to provide emergency interventional services for patients with critical cardiovascular disease following natural disasters. A feasibility study was performed by testing the Mini Mobile Cath Lab on dogs with ST-elevation myocardial infarction (STEMI) model in a hypothetical natural-disaster-stricken area. The Mini Mobile Cath Lab was transported to the hypothetical natural-disaster-stricken area by truck. Coronary angiography and primary percutaneous coronary intervention (PCI) were performed on six dogs with STEMI model. The transportation and transformation of the Mini Mobile Cath Lab were monitored and its functioning was evaluated through the results of animal experiments. The Mini Mobile Cath Lab could be transported by truck at an average speed of 80 km/h on mountain roads during daytime in the winter, under conditions of light snow (-15°C to -20°C/-68°F to -59°F). The average time required to prepare the Mini Mobile Cath Lab after transportation, in a wetland area, was 30 minutes. Coronary angiography, and primary PCI were performed successfully. This preliminary feasibility study of the use of the Mini Mobile Cath Lab for emergency interventional treatment of dogs with STEMI indicated that it may perform well in the rescue of critical cardiovascular disease following natural disasters.
A safety radiation marker in the cardiac catheterization lab.
Kostakou, Peggy M; Damaskos, Dimitris S; Dagre, Anna G; Makavos, Georgios A; Olympios, Christophoros D
2016-04-01
Nowadays, in order to deal with cardiovascular disease, coronary angiography (CRA) is the best tool and gold standard for diagnosis and assessment. CRA inevitably exposes both patient and operator to radiation. The purpose of this study was to calculate the radiation exposure in association with the radiation absorbed by interventional cardiologists, in order to estimate a safety radiation marker in the catheterization laboratory. In 794 successive patients undergoing CRA and in three interventional cardiologists the following parameters were examined: radioscopy duration, radiation exposure during fluoroscopy, total radiation exposure and the number of stents per procedure. Every interventional cardiologist was exposed to 562,936 μGym2 of total radiation during CRA procedures, to 833,371 μGym2 during elective CRA + percutaneous coronary intervention (PCI) procedures and to 328,250 μGym2 during primary CRA + PCI. Hence, the total amount of radiation that every angiographer was exposed to amounted to 1,724,557.5 μGym2 (median values). During the same period, the average radiation that every angiographer absorbed was 15,253 while the average dose of radiation absorbed during one procedure was 0.06 mSv for each operator. Therefore, the ratio between radiation exposure and the radiation finally absorbed by every operator was 113:1 μGym2/mSv. The present study, indicating the ratio above, offers a safety marker in order to realistically estimate the dose absorbed by interventional cardiologists, suggesting a specified number of permitted procedures and an effective level of radiation use protection tools.
Patient Decision Control and the Use of Cardiac Catheterization
Paasche-Orlow, Michael K.; Orner, Michelle B.; Stewart, Sabrina K.; Kressin, Nancy R.
2015-01-01
Background: Shared decision-making is a key determinant of patient-centered care. A lack of patient involvement in treatment decisions may explain persistent racial disparities in rates of cardiac catheterization (CCATH). To date, limited evidence exists to demonstrate whether patients who engage in shared decision-makingare more or less likely to undergo non-emergency CCATH. Objective: To assess the relationship between participation in the decision to undergo a CCATH and the use of CCATH. We also examined whether preference for or actual engagement in decision-making varied by patient race. Methods: We analyzed data from 826 male Veterans Administration patients for whom CCATH was indicated and who participated in the Cardiac Decision Making Study. Results: After controlling for confounders, patients reporting any degree of decision control were more likely to receive CCATH compared with those reporting no control (doctor made decision without patient input) (54% vs 39%, P<.0001). Across racial groups, patients were equally likely to report a preference for control over decision-making (P=.53) as well as to experience discordance between their preference for control and their perception of the actual decision-making process (P=.59). Therefore, these factors did not mediate racial disparities in rates of CCATH use. Conclusion: Shared decision-making is an essential feature of whole-person care. While participation in decision-making may not explain disparities in CCATH rates, further work is required to identify strategies to improve congruence between patients' desire for and actual control over decision-making to actualize patient-centered care. PMID:26331101
Garcia, Robert; Spitzer, Eric D
2017-10-01
Published literature indicates that the unjustified ordering or improper collection of urine for urinalysis or culture from either catheterized patients or those without indwelling devices, or misinterpretation of positive results, often leads to adverse health care events, including increased financial burdens, overreporting of mandated catheter-associated urinary tract infection events, overtreatment of patients with antimicrobial agents, selection of multidrug-resistant organisms, and Clostridium difficile infection. Moreover, national guidelines that provide evidence-based direction on core processes that form the basis for subsequent clinical therapy decisions or surveillance interpretations; that is, the appropriate ordering and collection of urine for laboratory testing and the treatment of patients with symptomatic urinary tract infection, are not widely known or lack adherence. This article provides published evidence on the influence of inappropriate ordering of urine specimens and subsequent treatment of asymptomatic bacteriuria and associated adverse effects; reviews research on bacterial contamination and preservation; and delineates best practices in the collection, handling, and testing of urine specimens for culture or for biochemical analysis in both catheterized and noncatheterized patients. The goal is to provide infection preventionists (IPs) with a cohesive evidence-based framework that will assist them in facilitating the implementation of a urine culture management program that reduces patient harms, enhances the accuracy of catheter-associated urinary tract infection surveillance, improves antibiotic stewardship, and reduces costs. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Komiyama, Kota; Ashikaga, Takashi; Inagaki, Dai; Miyabe, Tomonori; Arai, Marina; Yoshida, Kiyotaka; Miyazawa, Satoshi; Nakada, Akihiro; Kawamura, Iwanari; Masuda, Shinichiro; Nagamine, Sho; Hojo, Rintaro; Aoyama, Yuya; Tsuchiyama, Takaaki; Fukamizu, Seiji; Shibui, Takashi; Sakurada, Harumizu
2017-01-25
Sodium bicarbonate and ascorbic acid have been proposed to prevent contrast-induced nephropathy (CIN). The present study evaluated the effect of their combined use on CIN incidence.Methods and Results:We prospectively enrolled 429 patients with chronic kidney disease (CKD: baseline estimated glomerular filtration rate <60 mL/min/1.73 m 2 ) prior to elective coronary catheterization. CIN was defined as absolute (≥0.5 mg/dL) or relative (≥25%) increase in serum creatinine within 72 h. In the saline hydration (n=218) and combined sodium bicarbonate+ascorbic acid (n=211) groups, a total of 1,500-2,500 mL 0.9% saline was given before and after the procedure. In addition, the combination group received 20 mEq sodium bicarbonate and 3 g ascorbic acid i.v. before the procedure, followed by 2 g ascorbic acid after the procedure and a further 2 g after 12 h. There were no significant differences between the basic characteristics and contrast volume in the 2 groups. CIN occurred in 19 patients (8.7%) in the saline group, and in 6 patients (2.8%) in the combined treatment group (P=0.008). Combined sodium bicarbonate and ascorbic acid could prevent CIN following catheterization in CKD patients.
Management of bladder dysfunction and satisfaction of life after spinal cord injury in Norway
Hagen, Ellen Merete; Rekand, Tiina
2014-01-01
Background There is limited knowledge about bladder dysfunction and bladder management in persons with spinal cord injury (SCI) after discharge from the hospital in Norway. The impact of bladder dysfunction on satisfaction of life has been rarely explored. Setting Community-based survey from Norway. Methods An anonymous cross-sectional postal survey. A questionnaire was sent to the registered members of the Norwegian Spinal Cord Injuries Association. A total of 400 participants, with traumatic or non-traumatic SCI, received the questionnaire. Results A total of 248 subjects (62%), 180 men and 68 women, answered the questionnaire. Mean age was 54 years and mean time since injury 13.4 years. A total of 164 participants (66.1%) used intermittent catheterization for bladder emptying (48.5% women versus 72.8% men); more paraplegics than tetraplegics (77.2% versus 55.7%). Recommendations given at the Spinal Cord Units were thoroughly followed by persons who had used catheters more than 5 years. Use of incontinence pads were associated with reduced satisfaction of life. Conclusions The most common method of management of bladder dysfunction is clean intermittent catheterization in Norway. Recommendations were followed more thoroughly by persons who have used intermittent catheterization for more than 5 years. Spinal Cord Units are important source for information and guidance. PMID:24621024
Management of bladder dysfunction and satisfaction of life after spinal cord injury in Norway.
Hagen, Ellen Merete; Rekand, Tiina
2014-05-01
There is limited knowledge about bladder dysfunction and bladder management in persons with spinal cord injury (SCI) after discharge from the hospital in Norway. The impact of bladder dysfunction on satisfaction of life has been rarely explored. Community-based survey from Norway. An anonymous cross-sectional postal survey. A questionnaire was sent to the registered members of the Norwegian Spinal Cord Injuries Association. A total of 400 participants, with traumatic or non-traumatic SCI, received the questionnaire. A total of 248 subjects (62%), 180 men and 68 women, answered the questionnaire. Mean age was 54 years and mean time since injury 13.4 years. A total of 164 participants (66.1%) used intermittent catheterization for bladder emptying (48.5% women versus 72.8% men); more paraplegics than tetraplegics (77.2% versus 55.7%). Recommendations given at the Spinal Cord Units were thoroughly followed by persons who had used catheters more than 5 years. Use of incontinence pads were associated with reduced satisfaction of life. The most common method of management of bladder dysfunction is clean intermittent catheterization in Norway. Recommendations were followed more thoroughly by persons who have used intermittent catheterization for more than 5 years. Spinal Cord Units are important source for information and guidance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bargellini, Irene, E-mail: irenebargellini@hotmail.com; Turini, Francesca; Bozzi, Elena
To assess feasibility of proper hepatic artery catheterization using a 3D model obtained from preprocedural computed tomographic angiography (CTA), fused with real-time fluoroscopy, during transarterial chemoembolization of hepatocellular carcinoma. Twenty consecutive cirrhotic patients with hepatocellular carcinoma undergoing transarterial chemoembolization were prospectively enrolled onto the study. The early arterial phase axial images of the preprocedural CTA were postprocessed on an independent workstation connected to the angiographic system (Innova 4100; GE Healthcare, Milwaukee, WI), obtaining a 3D volume rendering image (VR) that included abdominal aorta, splanchnic arteries, and first and second lumbar vertebrae. The VR image was manually registered to the real-timemore » X-ray fluoroscopy, with the lumbar spine used as the reference. The VR image was then used as guidance to selectively catheterize the proper hepatic artery. The procedure was considered successful when performed with no need for intraarterial contrast injections or angiographic acquisitions. The procedure was successful in 19 (95 %) of 20 patients. In one patient, celiac trunk angiography was required for the presence of a significant ostial stenosis that was underestimated at computed tomography. Time for image reconstruction and registration was <10 min in all cases. The use of preprocedural CTA model with fluoroscopy enables confident and direct catheterization of the proper hepatic artery with no need for preliminary celiac trunk angiography, thus reducing radiation exposure and contrast media administration.« less
Niles, Nathaniel W; Conley, Sheila M; Yang, Rayson C; Vanichakarn, Pantila; Anderson, Tamara A; Butterly, John R; Robb, John F; Jayne, John E; Yanofsky, Norman N; Proehl, Jean A; Guadagni, Donald F; Brown, Jeremiah R
2010-01-01
Rural ST-segment elevation myocardial infarction (STEMI) care networks may be particularly disadvantaged in achieving a door-to-balloon time (D2B) of less than or equal to 90 minutes recommended in current guidelines. ST-ELEVATION MYOCARDIAL INFARCTION PROCESS UPGRADE PROJECT: A multidisciplinary STEMI process upgrade group at a rural percutaneous coronary intervention center implemented evidence-based strategies to reduce time to electrocardiogram (ECG) and D2B, including catheterization laboratory activation triggered by either a prehospital ECG demonstrating STEMI or an emergency department physician diagnosing STEMI, single-call catheterization laboratory activation, catheterization laboratory response time less than or equal to 30 minutes, and prompt data feedback. An ongoing regional STEMI registry was used to collect process time intervals, including time to ECG and D2B, in a consecutive series of STEMI patients presenting before (group 1) and after (group 2) strategy implementation. Significant reductions in time to first ECG in the emergency department and D2B were seen in group 2 compared with group 1. Important improvement in the process of acute STEMI patient care was accomplished in the rural percutaneous coronary intervention center setting by implementing evidence-based strategies. Copyright © 2010 Elsevier Inc. All rights reserved.
Zolfaghari, Mitra; Eybpoosh, Sana; Hazrati, Maryam
2012-12-01
To investigate the effects of Therapeutic Touch (TT) on anxiety, vital signs, and cardiac dysrhythmia in women undergoing cardiac catheterization. It was a quasi-experimental study. The participants had no history of hallucination, anxiety, or other psychological problems. Participants had to be conscious and have attained at least sixth-grade literacy level. Participants were randomly assigned into an intervention group (n = 23; received 10-15 minutes TT), a placebo group (n = 23; received 10-15 minutes simulated touch), and a control group (n = 23; did not receive any therapy). Data were collected using Spielberger's anxiety test, cardiac dysrhythmia checklist, and vital signs recording sheet. Statistical analyses were considered to be significant at α = .05 levels. Sixty-nine women ranging in age from 35 to 65 years participated. TT significantly decreased state anxiety p < 0.0001 but not trait anxiety (p = .88), decreased the incidence of all cardiac dysrhythmias p < 0.0001 except premature ventricular contraction (p = .01), and regulated vital signs p < 0.0001 in the intervention group versus placebo and control group. TT is an effective approach for managing state anxiety, regulating vital signs, and decreasing the incidence of cardiac dysrhythmia during stressful situations, such as cardiac catheterization, in Iranian cardiac patients.
Comparcini, Dania; Simonetti, Valentina; Blot, Stijn; Tomietto, Marco; Cicolini, Giancarlo
2017-01-01
To explore the relationship between the anatomical site of peripheral venous catheterization and risk of catheter-related phlebitis. Peripheral venous catheterization is frequently associated with phlebitis. Recent guidelines, recommend the use of an upper-extremity site for catheter insertion but no univocal consensus exists on the anatomical site with lower risk of phlebitis. Systematic review. We searched Medline (PubMed) and CINAHL (EBSCOhost) databases until the end of January 2017. We also reviewed the reference lists of retrieved articles and gray literature was excluded. Searches were limited to articles published in English with no restriction imposed to date of publication. The primary outcome was the incidence of phlebitis associated with anatomical site of peripheral catheterization. We included randomized controlled trials and observational studies on adult patients who required a peripheral catheter for the administration of medi- cation, intermittent or continuous fluid infusion. Antecubital fossa veins are associated with lower phlebitis rates, while hands veins are the most risky sites to develop phlebitis. There is no consensus regarding vein in forearm. Choosing the right anatomical site to insert a peripheral venous catheter is important to decrease phlebitis rate. Further studies should compare indwelling time in different anatomical sites with phlebitis rate. A more standardized approach in defining and assessing phlebitis among studies is recommended.
Wallace, Sean; Døhlen, Gaute; Holmstrøm, Henrik; Lund, Christian; Russell, David
2016-08-01
The aim of this prospective study was to determine the frequency and composition of cerebral microemboli in a pediatric population, during transcatheter closure of patent ductus arteriosus (PDA). Multifrequency transcranial Doppler was used to monitor cerebral blood flow velocity (CBFV) and detect microembolic signals (MES) in the middle cerebral artery in 23 patients (median age 18 months). MES were automatically identified and differentiated according to composition; gaseous or solid. The procedure was divided into five periods: Arterial catheterization; venous catheterization; ductal catheterization; angiography; device placement and release. Timing of catheter manipulations and MES were registered and compared. MES were detected in all patients. The median number of signals was 7, (minimum 1, maximum 28). Over 95 % of all MES were gaseous. 11 % were detected during device placement while 64 % were detected during angiographic studies, significantly higher than during any other period (P < 0.001). There was a moderate correlation between the number of MES and volume of contrast used, (R = 0.622, P < 0.01). There was no correlation with fluoroscopic time or duration of procedure. This is the first study to investigate the timing and composition of cerebral microemboli during PDA occlusion. Microemboli were related to specific catheter manipulations and correlated with the amount of contrast used.
Zhao, Shi-Jie; Zhong, Zhao-Shuang; Qi, Guo-Xian; Tian, Wen
2016-10-15
The efficacy of combining use of N-acetylcysteine (NAC) and sodium bicarbonate (SOB) in the prevention of contrast-induced nephropathy (CIN) after cardiac catheterization and percutaneous coronary intervention (PCI) is unclear. All relevant studies that compared the effect of combining the use of NAC and SOB with individual use on CIN in patients undergoing cardiac catheterization and PCI were identified by searching the databases including Pubmed, Embase, Cochrane Library, and Web of Science without time and language limitation. Only randomized controlled trials (RCTs) with full-text published were considered. Sixteen RCTs involving 4432 cases were included into this meta-analysis. The results showed there were no additional benefit in reduction of CIN in COM group (COM versus NAC: RR 0.85, 95% CI 0.70-1.03, P=0.103; COM versus SOB: RR 0.91, 95% CI 0.71-1.16, P=0.449), even in patients with diabetes mellitus (COM versus NAC: RR 1.11, 95% CI 0.71-1.75, P=0.646; COM versus SOB: RR 1.06, 95% CI 0.45-2.47, P=0.893), undergoing PCI procedure (COM versus NAC: RR0.76, 95% CI 0.39-1.47, P=0.411; COM versus SOB: RR0.96, 95% CI 0.65-1.40, P=0.814), or with baseline renal dysfunction (COM versus NAC: RR 0.89, 95% CI 0.70-1.14, P=0.366; COM versus SOB: RR 0.95, 95% CI 0.67-1.36, P=0.788). The present study demonstrated combining use of NAC and SOB was not significantly superior to individual use method in the prevention of CIN after cardiac catheterization and PCI. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Moreno, J G; Chancellor, M B; Karasick, S; King, S; Abdill, C K; Rivas, D A
1995-08-01
Quality of life issues prompted us to offer continent urinary diversion to quadriplegic women who required cystectomy for end-stage neurogenic vesical dysfunction complicated by urethral destruction as a result of chronic indwelling catheterization. Three women with spinal cord injury (SCI) and resultant quadriplegia of 5 to 15 years duration underwent continent urinary diversion. Preoperative evaluation and urodynamic studies in each showed a bladder capacity of less than 150mL, bilateral vesicoureteral reflux, recurrent febrile urinary tract infections, an incompetent urethral sphincter, and incontinence around an indwelling catheter in all three patients. Although highly motivated, these women showed minimal dexterity and were unable to perform urethral self-catheterization. Each was opposed to having an incontinent abdominal urinary stoma. The urinary reservoir was created from 30cm of detubularized right colon. The continence mechanism used an intussuscepted and imbricated ileocecal valve. The umbilicus was chosen as the urostomy site because of cosmetic appearance and ease of catheterization for a patient with minimal dexterity. Follow-up ranged from 18 to 30 months. Reservoir capacity ranged from 550 to 800mL without evidence of reflux or stomal leakage. The incidence of symptomatic autonomic dysreflexia and urinary tract infection decreased postoperatively in all patients. Of the two women who were sexually active, the frequency of activity increased from 8 to 15 episodes per month in one and 3 to 4 episodes per month in the other. Both reported improved sexual enjoyment. Body image and satisfaction with urologic management increased in all three patients. In conclusion, continent urinary diversion in selected quadriplegic patients is a reasonable alterative to incontinent intestinal urinary diversion. The umbilical stoma provides an excellent cosmetic result which patients with minimal dexterity are able to catheterize easily. Continent urinary diversion in women results in improved self-image, quality of life, and enables greater sexual satisfaction.
Shore, Neal D; Sethi, Parminder S
2010-09-01
Compare safety and tolerability of the Prolieve(®) System with the Targis(®) System using objective and subjective measures. Thirty-four men with symptomatic benign prostatic hyperplasia (BPH) were randomized to a single treatment with either the Prolieve or Targis system; 30 were treated and then followed for 6 months. After post-treatment bladder fill with ≥200 mL saline, patients were catheterized if they could not void after 2 hours or had a postvoid residual >150 mL. Catheter use, visual analog scale (VAS) tolerability scores, American Urological Association scores, and safety were assessed. After treatment, 15/16 (94%) Prolieve patients remained catheter-free compared with 3/14 (21%) Targis patients (P = 0.0001). Foley catheter indwelling time was 58.8 hours for the one Prolieve patient compared with 103.9 hrs (range 54-270 h) for the Targis patients (n = 9). Targis patients' catheterization requirements were: Seven Foley only, two intermittent self-catheters only, and two needing both. Intermittent self-catheterization continued for 1 month in two Targis patients. VAS tolerability scores were 24% to 50% lower during Prolieve treatment vs Targis (P < 0.05). Mean AUA scores for Prolieve improved from 21.2 at baseline to 12.3 and 7.9 at week 2 and month 6, respectively; for Targis, AUA scores improved from 22.9 at baseline to 17.9 and 10.9, respectively (P > 0.05). Overall, the incidence of device-related adverse events was 31% (Prolieve) compared with 64% (Targis) (P > 0.05)-most prevalently, urinary retention, dysuria, and hematuria. No device-related serious adverse events occurred. Prolieve provided enhanced near-term therapeutic benefit over Targis as assessed by catheterization, tolerability, and symptom relief, which may assist physician and patient decision-making when selecting an office-based transurethral microwave therapy option for patients.
Sildenafil exposure and hemodynamic effect after stage II single-ventricle surgery
Hill, Kevin D.; Tunks, Robert D.; Barker, Piers C. A.; Benjamin, Daniel K.; Cohen-Wolkowiez, Michael; Fleming, Gregory A.; Laughon, Matthew; Li, Jennifer S.
2013-01-01
Objective To determine sildenafil exposure and hemodynamic effect in children after stage II single-ventricle surgery. Design Prospective, dose escalation trial. Setting Single-center, pediatric catheterization laboratory. Patients 12 children post stage II single-ventricle surgical palliation and undergoing elective cardiac catheterization: median age 1.9 years (range: 0.8, 4.0), weight 11 kg (8, 13), 9 females, and 10 with a single right ventricle. Interventions Catheterization and echocardiography performed before and immediately after single-dose intravenous sildenafil (0.125, 0.25, 0.35, or 0.45 mg/kg over 20 minutes). Measurements Peak sildenafil and des-methyl sildenafil concentration, change in hemodynamic parameters measured by cardiac catheterization and echocardiography including indexed pulmonary vascular resistance, and myocardial performance. Main Results Maximum sildenafil concentrations ranged from 92–775 ng/ml and were above the in vitro threshold needed for 77% phosphodiesterase type-5 (PDE-5) inhibition in 80% of subjects and 90% inhibition in 80% of subjects with doses ≥0.35 mg/kg. Sildenafil lowered pulmonary vascular resistance index (PVRI) in all 12 subjects (median PVRI 2.2 [range: 1.6, 7.9]; decreased to 1.7 [1.2, 5.4] WU x m2; p<0.01) with no dose-response effect. Sildenafil improved pulmonary blood flow (+8% [0, 20], p=0.04) and saturations (+2% [0, 16], p=0.04) in those with baseline PVRI ≥2 WU x m2 (n=7). Change in saturations correlated inversely with change in PVRI (r2 = 0.74 p<0.01). Sildenafil also lowered mean blood pressure (−12% [−20, +10]; p=0.04). There was no change in cardiac index and no effect on myocardial performance. There were no adverse events. Conclusions Sildenafil demonstrated non-linear exposure with high inter-individual variability but was well tolerated and effectively lowered PVRI in all subjects. Sildenafil did not acutely improve myocardial performance or increase cardiac index. PMID:23823195
Losey, Aaron D; Lillaney, Prasheel; Martin, Alastair J; Cooke, Daniel L; Wilson, Mark W; Thorne, Bradford R H; Sincic, Ryan S; Arenson, Ronald L; Saeed, Maythem; Hetts, Steven W
2014-06-01
To compare in vitro navigation of a magnetically assisted remote-controlled (MARC) catheter under real-time magnetic resonance (MR) imaging with manual navigation under MR imaging and standard x-ray guidance in endovascular catheterization procedures in an abdominal aortic phantom. The 2-mm-diameter custom clinical-grade microcatheter prototype with a solenoid coil at the distal tip was deflected with a foot pedal actuator used to deliver 300 mA of positive or negative current. Investigators navigated the catheter into branch vessels in a custom cryogel abdominal aortic phantom. This was repeated under MR imaging guidance without magnetic assistance and under conventional x-ray fluoroscopy. MR experiments were performed at 1.5 T by using a balanced steady-state free precession sequence. The mean procedure times and percentage success data were determined and analyzed with a linear mixed-effects regression analysis. The catheter was clearly visible under real-time MR imaging. One hundred ninety-two (80%) of 240 turns were successfully completed with magnetically assisted guidance versus 144 (60%) of 240 turns with nonassisted guidance (P < .001) and 119 (74%) of 160 turns with standard x-ray guidance (P = .028). Overall mean procedure time was shorter with magnetically assisted than with nonassisted guidance under MR imaging (37 seconds ± 6 [standard error of the mean] vs 55 seconds ± 3, P < .001), and time was comparable between magnetically assisted and standard x-ray guidance (37 seconds ± 6 vs 44 seconds ± 3, P = .045). When stratified by angle of branch vessel, magnetic assistance was faster than nonassisted MR guidance at turns of 45°, 60°, and 75°. In this study, a MARC catheter for endovascular navigation under real-time MR imaging guidance was developed and tested. For catheterization of branch vessels arising at large angles, magnetically assisted catheterization was faster than manual catheterization under MR imaging guidance and was comparable to standard x-ray guidance.
Infection and natural history of emergency department-placed central venous catheters.
LeMaster, Christopher H; Schuur, Jeremiah D; Pandya, Darshan; Pallin, Daniel J; Silvia, Jennifer; Yokoe, Deborah; Agrawal, Ashish; Hou, Peter C
2010-11-01
Central line-associated bloodstream infection (CLABSI, hereafter referred to in this paper as "bloodstream infection") is a leading cause of hospital-acquired infection. To our knowledge, there are no previously published studies designed to determine the rate of bloodstream infection among central venous catheters placed in the emergency department (ED). We design a retrospective chart review methodology to determine bloodstream infection and duration of catheterization for central venous catheters placed in the ED. Using hospital infection control, administrative, and ED billing databases, we identified patients with central venous catheters placed in the ED between January 1, 2007, and December 31, 2008, at one academic, urban ED with an annual census of 57,000. We performed a structured, explicit chart review to determine duration of catheterization and confirm bloodstream infection. We screened 4,251 charts and identified 656 patients with central venous catheters inserted in the ED, 3,622 catheter-days, and 7 bloodstream infections. The rate of bloodstream infection associated with central venous catheters placed in the ED was 1.93 per 1,000 catheter-days (95% confidence interval 0.50 to 3.36). The mean duration of catheterization was 5.5 days (median 4; range 1 to 29 days). Among infected central venous catheters, the mean duration of catheterization was 8.6 days (median 7; range 2 to 19 days). A total of 667 central venous catheters were placed in the internal jugular (392; 59%), subclavian (145; 22%), and femoral (130; 19%) veins. The sensitivity of using ED procedural billing code for identifying ED-placed central venous catheters among patients subsequently admitted to any ICU was 74.9% (95% confidence interval 71.4% to 78.3%). The rate of ED bloodstream infection at our institution is similar to current rates in ICUs. Central venous catheters placed in the ED remain in admitted patients for a substantial period. Copyright © 2010 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.
Risk Factors for Catheter Associated Urinary Tract Infections in a Pediatric Institution.
Lee, Nora G; Marchalik, Daniel; Lipsky, Andrew; Rushton, H Gil; Pohl, Hans G; Song, Xiaoyan
2016-04-01
Catheter associated urinary tract infections are an essential measure for health care quality improvement that affects reimbursement through hospital acquired condition reduction programs in adult patients. With the mounting importance of preventing such infections we evaluated risk factors for acquiring catheter associated urinary tract infections in pediatric patients. All catheter associated urinary tract infections were identified at 1 pediatric institution from September 2010 to August 2014 from a prospective database maintained by the infection control office. To identify risk factors patients with a catheter associated urinary tract infection were individually matched to control patients with a urinary catheter but without infection by age, gender, date and the hospital location of the infection in 1:2 fashion. A total of 50 patients with catheter associated urinary tract infection were identified and matched to 100 control patients. Compared to controls the patients with infection were more likely to have a catheter in place for longer (2.9 days, OR 1.08, 95% CI 1.01, 1.15, p = 0.02). They were also more likely to be on contact precautions (OR 4.00, 95% CI 1.73, 9.26, p = 0.001), and have concurrent infections (OR 3.04, 95% CI 1.39, 6.28, p = 0.005) and a history of catheterization (OR 3.24, 95% CI 1.55, 6.77, p = 0.002). Using a conditional multivariate regression model the 3 most predictive variables were duration of catheter drainage, contact isolation status and history of catheterization. Longer duration of urinary catheter drainage, positive contact precautions status and a history of catheterization appear to be associated with a higher risk of catheter associated urinary tract infection in hospitalized pediatric patients. Physicians should attempt to decrease the duration of catheterization, especially in patients who meet these criteria, to minimize the risk of catheter associated urinary tract infection. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Lin, C Huie; Desai, Sanyukta; Nicolas, Ramzi; Gauvreau, Kimberlee; Foerster, Susan; Sharma, Anshuman; Armsby, Laurie; Marshall, Audrey C; Odegard, Kirsten; DiNardo, James; Vincent, Julie; El-Said, Howaida; Spaeth, James; Goldstein, Bryan; Holzer, Ralf; Kreutzer, Jackie; Balzer, David; Bergersen, Lisa
2015-10-01
Sedation/anesthesia is critical to cardiac catheterization in the pediatric/congenital heart patient. We sought to identify current sedation/anesthesia practices, the serious adverse event rate related to airway, sedation, or anesthesia, and the rate of intra-procedural conversion from procedural sedation to the use of assisted ventilation or an artificial airway. Data from 13,611 patients who underwent catheterization at eight institutions were prospectively collected from 2007 to 2010. Ninety-four (0.69 %) serious sedation/airway-related adverse events occurred; events were more likely to occur in smaller patients (<4 kg, OR 4.4, 95 % CI 2.3-8.2, p < 0.001), patients with non-cardiac comorbidities (OR 1.7, 95 % CI 1.1-26, p < 0.01), and patients with low mixed venous oxygen saturation (OR 2.3, 95 % CI 1.4-3.6, p < 0.001). Nine thousand three hundred and seventy-nine (69 %) patients were initially managed with general endotracheal anesthesia, LMA, or tracheostomy, whereas 4232 (31 %) were managed with procedural sedation without an artificial airway, of which 75 (1.77 %) patients were converted to assisted ventilation/general anesthesia. Young age (<12 months, OR 5.2, 95 % CI 2.3-11.4, p < 0.001), higher-risk procedure (category 4, OR 10.1, 95 % CI 6.5-15.6, p < 0.001), and continuous pressor/inotrope requirement (OR 11.0, 95 % CI 8.6-14.0, p < 0.001) were independently associated with conversion. Cardiac catheterization in pediatric/congenital patients was associated with a low rate of serious sedation/airway-related adverse events. Smaller patients with non-cardiac comorbidities or low mixed venous oxygen saturation may be at higher risk. Patients under 1 year of age, undergoing high-risk procedures, or requiring continuous pressor/inotrope support may be at higher risk of requiring conversion from procedural sedation to assisted ventilation/general anesthesia.
Spiliopoulos, S; Katsanos, K; Diamantopoulos, A; Karnabatidis, D; Siablis, D
2011-05-01
To present the results of a prospective, randomized, single-centre study investigating local anaesthesia before percutaneous common femoral artery (CFA) puncture and catheterization with the use of ultrasound-guided injection of lidocaine versus standard infiltration by manual palpation. Patients scheduled to undergo diagnostic or therapeutic transfemoral catheter-based procedures gave informed consent and were randomized in two groups. In the first arm local anaesthesia with lidocaine hydrochloride 1% was performed under ultrasound guidance (group U/S), while in the second arm the standard method of manual artery palpation was applied (group M). In both groups, subsequent CFA catheterization was achieved under ultrasound guidance. The primary study endpoint was peri-procedural pain level evaluated with a visual-analogue scale (VAS score 0-10). Between January 2009 and 2010, 200 patients (161 men, mean age 63±12 years) were equally assigned to each group without any significant differences in baseline demographics. Patients in group U/S experienced significantly less pain during CFA catheterization in comparison with group M with a difference of three points in mean VAS score reported (1.6±1.6 versus 4.6±1.9, p<0.0001). In addition, significantly less volume of lidocaine was used in group U/S compared to group M (16±2.7 versus 19±0.8ml, p<0.001).Total vascular access time was similar in both groups (4.4±1.3 versus 4.5±1.3min). Overall complications included two small groin haematomas in each group. Ultrasound-guided local anaesthesia of the CFA prior to percutaneous transcatheter procedures is safe and achieves superior levels of analgesia with minimal patient pain and discomfort compared to the standard method of manual palpation. Copyright © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Sadeghi, Mohsen Mirmohammad; Gharipour, Mojgan; Nilforoush, Peiman; Shamsolkotabi, Hamid; Sadeghi, Hamid Mirmohammad; Kiani, Amjad; Sadeghi, Pouya Mirmohammad; Farahmand, Niloufar
2011-04-01
There is limited data about the influence of timing of cardiac surgery in relation to diagnostic angiography and/or the impact of the amount of contrast media used during angiography on the occurance of acute renal failure (ARF). Therefore, in the present study the effect of the time interval between diagnostic angiography and cardiac surgery and also the amount of contrast media used during the diagnostic procedure on the incidence of ARF after cardiac surgery was investigated. Data of 1177 patients who underwent different types of cardiac surgeries after cardiac catheterization were prospectively examined. The influence of time interval between cardiac catheterization and surgery as well as the amount of contrast agent on postoperative ARF were assessed using multivariable logistic regression. The patients who progressed to ARF were more likely to have received a higher dose of contrast agent compared to the mean dose. However, the time interval between cardiac surgery and last catheterization was not significantly different between the patients with and without ARF (p = 0.05). Overall, postoperative peak creatinine was highest on day 0, then decreased and remained significantly unchanged after this period. Overall prevalence of acute renal failure during follow-up period had a changeable trend and had the highest rates in days 1 (53.57%) and 6 (52.17%) after surgery. Combined coronary bypass and valve surgery were the strongest predictor of postoperative ARF (OR: 4.976, CI = 1.613-15.355 and p = 0.002), followed by intra-aortic balloon pump insertion (OR: 6.890, CI = 1.482-32.032 and p = 0.009) and usage of higher doses of contrast media agent (OR: 1.446, CI = 1.033-2.025 and p = 0.031). Minimizing the amount of contrast agent has a potential role in reducing the incidence of postoperative ARF in patients undergoing cardiac surgery, but delaying cardiac surgery after exposure to these agents might not have this protective effect.
Power, John A; Thompson, Diane V; Rayarao, Geetha; Doyle, Mark; Biederman, Robert W W
2016-05-01
Invasive cardiac catheterization is the venerable "gold standard" for diagnosing constrictive pericarditis. However, its sensitivity and specificity vary dramatically from center to center. Given the ability to unequivocally define segments of the pericardium with the heart via radiofrequency tissue tagging, we hypothesize that cardiac magnetic resonance has the capability to be the new gold standard. All patients who were referred for cardiac magnetic resonance evaluation of constrictive pericarditis underwent cardiac magnetic resonance radiofrequency tissue tagging to define visceral-parietal pericardial adherence to determine constriction. This was then compared with intraoperative surgical findings. Likewise, all preoperative cardiac catheterization testing was reviewed in a blinded manner. A total of 120 patients were referred for clinical suspicion of constrictive pericarditis. Thirty-nine patients were defined as constrictive pericarditis positive solely via radiofrequency tissue-tagging cardiac magnetic resonance, of whom 21 were positive, 4 were negative, and 1 was equivocal for constrictive pericarditis, as defined by cardiac catheterization. Of these patients, 16 underwent pericardiectomy and were surgically confirmed. There was 100% agreement between cardiac magnetic resonance-defined constrictive pericarditis positivity and postsurgical findings. No patients were misclassified by cardiac magnetic resonance. In regard to the remaining constrictive pericarditis-positive patients defined by cardiac magnetic resonance, 10 were treated medically, declined, were ineligible for surgery, or were lost to follow-up. Long-term follow-up of those who were constrictive pericarditis negative by cardiac magnetic resonance showed no early or late crossover to the surgery arm. Cardiac magnetic resonance via radiofrequency tissue tagging offers a unique, efficient, and effective manner of defining clinically and surgically relevant constrictive pericarditis. Specifically, no patient who was identified with constriction via cardiac magnetic resonance underwent inappropriate sternotomy. However, catheterization had substantial and unacceptable false-positive and false-negative rates with important clinical ramifications. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
The role of lasers in modern urology.
Dołowy, Łukasz; Krajewski, Wojciech; Dembowski, Janusz; Zdrojowy, Romuald; Kołodziej, Anna
2015-01-01
The functioning of modern urological departments and the high level of service they provide is possible through, among other things, the use of modern laser techniques. Open operations have been replaced by minimally invasive procedures, and classical surgical tools by advanced lasers. The search for new applications with lasers began as technology developed. Among many devices available, holmium, diode and thulium lasers are currently the most popular. Depending on the wavelength, the absorption by water and hemoglobin and the depth of penetration, lasers can be used for coagulation, vaporization and enucleation. In many centres, after all the possibilities of pharmacological treatment have been exhausted, lasers are used as the primary treatment for patients with benign prostatic hyperplasia, with therapeutic results that are better than those obtained through open or endoscopic operations. The use of lasers in the treatment of urolithiasis, urinary strictures and bladder tumours has made treatment of older patients with multiple comorbidities safe, without further necessity to modify the anticoagulant drug treatment. Laser procedures are additionally less invasive, reduce hospitalization time and enable a shorter bladder catheterization time, sometimes even eliminating the need for bladder catherterization completely. Such procedures are also characterized by more stable outcomes and a lower number of reoperations. There are also indications that with the increased competition among laser manufacturers, decreased purchase and maintenance costs, and increased operational safety, laser equipment will become mandatory and indispensable asset in all urology wards.
New laser treatment approaches for benign prostatic hyperplasia.
Fried, Nathaniel M
2007-01-01
The recent introduction of higher power 100 W holmium:yttrium-aluminum-garnet (Ho:YAG) and 80 W potassium titanyl phosphate lasers for rapid incision and vaporization of the prostate has resulted in renewed interest in the use of lasers for treatment of benign prostatic hyperplasia (BPH). Although long-term studies are still lacking, short-term results demonstrate that these procedures are at least as safe and effective in relieving BPH symptoms as transurethral resection of the prostate and may provide reduced morbidity. Other laser techniques, such as interstitial laser coagulation and contact laser vaporization of the prostate, have lost popularity due to complications with increased catheterization time, irritative symptoms, and infection rates. Although Ho:YAG laser enucleation of the prostate is more difficult to learn and a slower procedure than potassium titanyl phosphate laser vaporization, the Ho:YAG laser is currently the most proven laser technique for BPH treatment. This article reviews the latest developments in laser treatment of BPH over the past 2 years and provides a view toward the future of lasers in the treatment of BPH.
Saturated Salt Solution Method: A Useful Cadaver Embalming for Surgical Skills Training
Hayashi, Shogo; Homma, Hiroshi; Naito, Munekazu; Oda, Jun; Nishiyama, Takahisa; Kawamoto, Atsuo; Kawata, Shinichi; Sato, Norio; Fukuhara, Tomomi; Taguchi, Hirokazu; Mashiko, Kazuki; Azuhata, Takeo; Ito, Masayuki; Kawai, Kentaro; Suzuki, Tomoya; Nishizawa, Yuji; Araki, Jun; Matsuno, Naoto; Shirai, Takayuki; Qu, Ning; Hatayama, Naoyuki; Hirai, Shuichi; Fukui, Hidekimi; Ohseto, Kiyoshige; Yukioka, Tetsuo; Itoh, Masahiro
2014-01-01
Abstract This article evaluates the suitability of cadavers embalmed by the saturated salt solution (SSS) method for surgical skills training (SST). SST courses using cadavers have been performed to advance a surgeon's techniques without any risk to patients. One important factor for improving SST is the suitability of specimens, which depends on the embalming method. In addition, the infectious risk and cost involved in using cadavers are problems that need to be solved. Six cadavers were embalmed by 3 methods: formalin solution, Thiel solution (TS), and SSS methods. Bacterial and fungal culture tests and measurement of ranges of motion were conducted for each cadaver. Fourteen surgeons evaluated the 3 embalming methods and 9 SST instructors (7 trauma surgeons and 2 orthopedists) operated the cadavers by 21 procedures. In addition, ultrasonography, central venous catheterization, and incision with cauterization followed by autosuture stapling were performed in some cadavers. The SSS method had a sufficient antibiotic effect and produced cadavers with flexible joints and a high tissue quality suitable for SST. The surgeons evaluated the cadavers embalmed by the SSS method to be highly equal to those embalmed by the TS method. Ultrasound images were clear in the cadavers embalmed by both the methods. Central venous catheterization could be performed in a cadaver embalmed by the SSS method and then be affirmed by x-ray. Lungs and intestines could be incised with cauterization and autosuture stapling in the cadavers embalmed by TS and SSS methods. Cadavers embalmed by the SSS method are sufficiently useful for SST. This method is simple, carries a low infectious risk, and is relatively of low cost, enabling a wider use of cadavers for SST. PMID:25501070
Robot-assisted simple prostatectomy: multi-institutional outcomes for glands larger than 100 grams.
Vora, Anup; Mittal, Sameer; Hwang, Jonathan; Bandi, Gaurav
2012-05-01
To present our experience with robot-assisted simple prostatectomy in patients with large gland adenoma (>100 g) that would not be amenable to transurethral treatments. From August 2009 to May 2011, 13 robot-assisted simple suprapubic prostatectomies were performed in patients with symptomatic large gland (>100 g) prostatomegaly on transrectal ultrasonography (mean 163 cc). Essential aspects of our technique include a transverse cystotomy just proximal to the prostatovesical junction and use of a robotic tenotomy grasper to aid in adenoma dissection. Mean operative time was 179 minutes (range 90-270 min), and mean estimated blood loss was 219 mL (range 50-500 mL). Mean hospital stay was 2.7 days (range 1-8 d), and the mean urethral catheterization time was 8.8 days (range 5-14 d). None of the patients needed blood transfusion. One patient had an intraoperative urinary leak after bladder closure that was managed with prolonged urethral catheterization (14 d). Histopathologic analysis confirmed benign prostatic hyperplasia (BPH) in all patients, and mean specimen weight on pathologic examination was 127 g (range 100-165 g). Mean follow-up duration was 7.2 months with all patients having a minimum of a 4-month follow-up. Significant improvements were noted in the International Prostate Symptom Score (preoperative vs postoperative 18.1 vs 5.3, p<0.001) and the maximum urine flow rate (preoperative vs postoperative 4.3 vs 19.1 mL/min, P<0.001). Minimally invasive robot-assisted simple prostatectomy is technically feasible in patients with large volume (>100 g) BPH and is associated with significant improvements in obstructive urinary symptoms. Surgeons with robotic expertise may consider using this approach for treatment of their patients with large volume BPH.
Three-dimensional Image Fusion Guidance for Transjugular Intrahepatic Portosystemic Shunt Placement.
Tacher, Vania; Petit, Arthur; Derbel, Haytham; Novelli, Luigi; Vitellius, Manuel; Ridouani, Fourat; Luciani, Alain; Rahmouni, Alain; Duvoux, Christophe; Salloum, Chady; Chiaradia, Mélanie; Kobeiter, Hicham
2017-11-01
To assess the safety, feasibility and effectiveness of image fusion guidance with pre-procedural portal phase computed tomography with intraprocedural fluoroscopy for transjugular intrahepatic portosystemic shunt (TIPS) placement. All consecutive cirrhotic patients presenting at our interventional unit for TIPS creation from January 2015 to January 2016 were prospectively enrolled. Procedures were performed under general anesthesia in an interventional suite equipped with flat panel detector, cone-beam computed tomography (CBCT) and image fusion technique. All TIPSs were placed under image fusion guidance. After hepatic vein catheterization, an unenhanced CBCT acquisition was performed and co-registered with the pre-procedural portal phase CT images. A virtual path between hepatic vein and portal branch was made using the virtual needle path trajectory software. Subsequently, the 3D virtual path was overlaid on 2D fluoroscopy for guidance during portal branch cannulation. Safety, feasibility, effectiveness and per-procedural data were evaluated. Sixteen patients (12 males; median age 56 years) were included. Procedures were technically feasible in 15 of the 16 patients (94%). One procedure was aborted due to hepatic vein catheterization failure related to severe liver distortion. No periprocedural complications occurred within 48 h of the procedure. The median dose-area product was 91 Gy cm 2 , fluoroscopy time 15 min, procedure time 40 min and contrast media consumption 65 mL. Clinical benefit of the TIPS placement was observed in nine patients (56%). This study suggests that 3D image fusion guidance for TIPS is feasible, safe and effective. By identifying virtual needle path, CBCT enables real-time multiplanar guidance and may facilitate TIPS placement.
Transurethral vaporesection of prostate: diode laser or thulium laser?
Tan, Xinji; Zhang, Xiaobo; Li, Dongjie; Chen, Xiong; Dai, Yuanqing; Gu, Jie; Chen, Mingquan; Hu, Sheng; Bai, Yao; Ning, Yu
2018-05-01
This study compared the safety and effectiveness of the diode laser and thulium laser during prostate transurethral vaporesection for treating benign prostate hyperplasia (BPH). We retrospectively analyzed 205 patients with BPH who underwent a diode laser or thulium laser technique for prostate transurethral vaporesection from June 2016 to June 2017 and who were followed up for 3 months. Baseline characteristics of the patients, perioperative data, postoperative outcomes, and complications were compared. We also assessed the International Prostate Symptom Score (IPSS), quality of life (QoL), maximum flow rate (Q max ), average flow rate (AFR), and postvoid residual volume (PVR) at 1 and 3 months postoperatively to evaluate the functional improvement of each group. There were no significant differences between the diode laser and thulium laser groups related to age, prostate volume, operative time, postoperative hospital stays, hospitalization costs, or perioperative data. The catheterization time was 3.5 ± 0.8 days for the diode laser group and 4.7 ± 1.8 days for the thulium laser group (p < 0.05). Each group had dramatic improvements in IPSS, QoL, Q max , AFR, and PVR compared with the preoperative values (p < 0.05), although there were no significant differences between the two groups. Use of both diode laser and thulium laser contributes to safe, effective transurethral vaporesection in patients with symptomatic BPH. Diode laser, however, is better than thulium laser for prostate transurethral vaporesection because of its shorter catheterization time. The choice of surgical approach is more important than the choice of laser types during clinical decision making for transurethral laser prostatectomy.
Treatment of Angina and Microvascular Coronary Dysfunction
Samim, Arang; Nugent, Lynn; Mehta, Puja K.; Shufelt, Chrisandra; Merz, C. Noel Bairey
2014-01-01
Opinion statement Microvascular coronary dysfunction (MCD) is an increasingly recognized cause of cardiac ischemia and angina, more commonly diagnosed in women. Patients with MCD present with the triad of persistent chest pain, ischemic changes on stress testing, and no obstructive coronary artery disease (CAD) on cardiac catheterization. Data from National Heart, Lung and Blood Institute (NHLBI)-sponsored Women’s Ischemia Syndrome Evaluation (WISE) study has shown that the diagnosis of MCD is not benign, with a 2.5% annual risk of adverse cardiac events including myocardial infarction, stroke, congestive heart failure, or death. The gold standard diagnostic test for MCD is an invasive coronary reactivity test (CRT), which uses acetylcholine, adenosine, and nitroglycerin to test the endothelial dependent and independent, microvascular and macrovascular coronary function. The CRT allows for diagnostic and treatment options as well as further risk stratifying patients for future cardiovascular events. Treatment of angina and MCD should be aimed at ischemia disease management to reduce risk of adverse cardiac events, ameliorating symptoms to improve quality of life, and to decrease the morbidity from unnecessary and repeated cardiac catheterization in patients with open coronary arteries. A comprehensive treatment approach aimed at risk factor managment, including lifestyle counseling regarding smoking cessation, nutrition and physical activity should be initiated. Current pharmacotherapy for MCD can include the treatment of microvascular endothelial dysfunction (statins, angiotensin-converting enzyme inhibitor, low dose aspirin), as well as treatment for angina and myocardial ischemia (beta blockers, calcium channel blockers, nitrates, ranolazine). Additional symptom management techniques can include tri-cyclic medication, enhanced external counterpulsation, autogenic training, and spinal cord stimulation. While our current therapies are effective in the treatment of angina and MCD, large randomized outcome trials are needed to optimize strategies to improve morbidity and mortality. PMID:20842559
Saturated salt solution method: a useful cadaver embalming for surgical skills training.
Hayashi, Shogo; Homma, Hiroshi; Naito, Munekazu; Oda, Jun; Nishiyama, Takahisa; Kawamoto, Atsuo; Kawata, Shinichi; Sato, Norio; Fukuhara, Tomomi; Taguchi, Hirokazu; Mashiko, Kazuki; Azuhata, Takeo; Ito, Masayuki; Kawai, Kentaro; Suzuki, Tomoya; Nishizawa, Yuji; Araki, Jun; Matsuno, Naoto; Shirai, Takayuki; Qu, Ning; Hatayama, Naoyuki; Hirai, Shuichi; Fukui, Hidekimi; Ohseto, Kiyoshige; Yukioka, Tetsuo; Itoh, Masahiro
2014-12-01
This article evaluates the suitability of cadavers embalmed by the saturated salt solution (SSS) method for surgical skills training (SST). SST courses using cadavers have been performed to advance a surgeon's techniques without any risk to patients. One important factor for improving SST is the suitability of specimens, which depends on the embalming method. In addition, the infectious risk and cost involved in using cadavers are problems that need to be solved. Six cadavers were embalmed by 3 methods: formalin solution, Thiel solution (TS), and SSS methods. Bacterial and fungal culture tests and measurement of ranges of motion were conducted for each cadaver. Fourteen surgeons evaluated the 3 embalming methods and 9 SST instructors (7 trauma surgeons and 2 orthopedists) operated the cadavers by 21 procedures. In addition, ultrasonography, central venous catheterization, and incision with cauterization followed by autosuture stapling were performed in some cadavers. The SSS method had a sufficient antibiotic effect and produced cadavers with flexible joints and a high tissue quality suitable for SST. The surgeons evaluated the cadavers embalmed by the SSS method to be highly equal to those embalmed by the TS method. Ultrasound images were clear in the cadavers embalmed by both the methods. Central venous catheterization could be performed in a cadaver embalmed by the SSS method and then be affirmed by x-ray. Lungs and intestines could be incised with cauterization and autosuture stapling in the cadavers embalmed by TS and SSS methods. Cadavers embalmed by the SSS method are sufficiently useful for SST. This method is simple, carries a low infectious risk, and is relatively of low cost, enabling a wider use of cadavers for SST.
Truong, Uyen; Patel, Sonali; Kheyfets, Vitaly; Dunning, Jamie; Fonseca, Brian; Barker, Alex J; Ivy, Dunbar; Shandas, Robin; Hunter, Kendall
2015-09-16
Pediatric pulmonary hypertension (PH) remains a disease with high morbidity and mortality in children. Understanding ventricular-vascular coupling, a measure of how well matched the ventricular and vascular function are, may elucidate pathway leading to right heart failure. Ventricular vascular coupling ratio (VVCR), comprised of effective elastance (Ea, index of arterial load) and right ventricular maximal end-systolic elastance (Ees, index of contractility), is conventionally determined by catheterization. Here, we apply a non-invasive approach to determining VVCR in pediatric subjects with PH. This retrospective study included PH subjects who had a cardiovascular magnetic resonance (CMR) study within 14 days of cardiac catheterization. PH was defined as mean pulmonary artery pressure (mPAP) ≥ 25 mmHg on prior or current catheterization. A non-invasive measure of VVCR was derived from CMR-only (VVCRm) and compared to VVCR estimated by catheterization-derived single beat estimation (VVCRs). Indexed pulmonary vascular resistance (PVRi) and pulmonary vascular reactivity were determined during the catheterization procedure. Pearson correlation coefficients were calculated between PVRi and VVCRm. Receiver operating characteristic (ROC) curve analysis determined the diagnostic value of VVCRm in predicting vascular reactivity. Seventeen subjects (3 months-23 years; mean 11.3 ± 7.4 years) were identified between January 2009-August 2013 for inclusion with equal gender distributions. Mean mPAP was 35 mmHg ± 15 and PVRi was 8.5 Woods unit x m2 ± 7.8. VVCRm (range 0.43-2.82) increased with increasing severity as defined by PVRi (p < 0.001), and was highly correlated with PVRi (r = 0.92, 95 % CI 0.79-0.97, p < 0.0001). Regression of VVCRm and PVRi demonstrated differing lines when separated by reactivity. VVCRm was significantly correlated with VVCRs (r = 0.79, CI 0.48-0.99, p <0.0001). ROC curve analysis showed high accuracy of VVCRm in determining vascular reactivity (VVCR = 0.85 had a sensitivity of 100 % and a specificity of 80 %) with an area under the curve of 0.89 (p = 0.008). Measurement of VVCRm in pediatrics is feasible. Pulmonary vascular non-reactivity may be contribute to ventricular-vascular decoupling in severe PH. Therapeutic intervention to maintain a low vascular afterload in reactive patients may preserve right ventricular functional reserve and delay the onset of RV-PA decoupling. Use of VVCRm may have significant prognostic implication.
Badri, Marwan; Abdelbaky, Amr; Li, Shuang; Chiswell, Karen; Wang, Tracy Y
2017-09-22
Current guidelines recommend early P2Y 12 inhibitor administration in non-ST-elevation myocardial infarction, but it is unclear if precatheterization use is associated with longer delays to coronary artery bypass grafting (CABG) or higher risk of post-CABG bleeding and transfusion. This study examines the patterns and outcomes of precatheterization P2Y 12 inhibitor use in non-ST-elevation myocardial infarction patients who undergo CABG. Retrospective analysis was done of 20 304 non-ST-elevation myocardial infarction patients in the ACTION (Acute Coronary Treatment and Intervention Outcomes Network) Registry (2009-2014) who underwent catheterization within 24 hours of admission and CABG during the index hospitalization. Using inverse probability-weighted propensity adjustment, we compared time from catheterization to CABG, post-CABG bleeding, and transfusion rates between patients who did and did not receive precatheterization P2Y 12 inhibitors. Among study patients, 32.9% received a precatheterization P2Y 12 inhibitor (of these, 2.2% were given ticagrelor and 3.7% prasugrel). Time from catheterization to CABG was longer among patients who received precatheterization P2Y 12 inhibitor (median 69.9 hours [25th, 75th percentiles 28.2, 115.8] versus 43.5 hours [21.0, 71.8], P <0.0001), longer for patients treated with prasugrel (median 114.4 hours [66.5, 155.5]) or ticagrelor (90.4 hours [48.7, 124.5]) compared with clopidogrel (69.3 [27.5, 114.6], P <0.0001). Precatheterization P2Y 12 inhibitor use was associated with a higher risk of post-CABG major bleeding (75.7% versus 73.4%, adjusted odds ratio 1.33, 95% confidence interval 1.22-1.45, P <0.0001) and transfusion (47.6% versus 35.7%, adjusted odds ratio 1.51, 95% confidence interval 1.41-1.62, P <0001); these relationships did not differ among patients treated with clopidogrel, prasugrel, or ticagrelor. Precatheterization P2Y 12 inhibitor use occurs commonly among non-ST-elevation myocardial infarction patients who undergo early catheterization and in-hospital CABG. Despite longer delays to surgery, the majority of pretreated patients proceed to CABG <3 days postcatheterization. Precatheterization P2Y 12 inhibitor use is associated with higher risks of postoperative bleeding and transfusion. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Ahmad, Fareed; Mangano, Robert; Shore, Shirah; Polimenakos, Anastasios
2017-10-01
This is a case report of premature low birth weight infant with hypoplasia of left heart structures and a large malaligned VSD who underwent successful staged approach of biventricular repair. We obtained qualitative and quantitative echocardiographic, MRI, and conventional catheterization data to support stepwise strategy towards LV rehabilitation to sustain adequate cardiac output. A thorough and intense follow-up has shown significant growth of left heart structures and favorable clinical status following staged biventricular repair. Our data indicate usefulness of qualitative and quantitative advanced complimentary multi-imaging modalities in predicting the postnatal growth potential of critically underdeveloped left heart structures.
Pregnancy-Related Coronary Artery Dissection: Recognition of a Life Threatening Process.
Robinson, Julie R
Pregnancy-related spontaneous coronary artery dissection (P-SCAD) is a rare but life-threatening condition of the peripartum and postpartum mother. The gold standard of diagnosing P-SCAD is a left cardiac catheterization; however, this diagnostic tool may not be used early because myocardial infarction is not typically a top differential diagnosis for women and especially young pregnant women presenting with acute chest pain. Providers and registered nurses, particularly those in the prehospital setting, the emergency department, and labor and delivery units, should be aware of signs, symptoms, potential risk factors, and diagnostic results that could indicate P-SCAD and initiate early and appropriate treatment to improve maternal outcomes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carnevale, Francisco C., E-mail: fcarnevale@uol.com.br; Antunes, Alberto A., E-mail: antunesuro@uol.com.br
2013-12-15
Prostatic artery embolization (PAE) has emerged as an alternative to surgical treatments for benign prostatic hyperplasia (BPH). Patient selection and refined technique are essential for good results. Urodynamic evaluation and magnetic resonance imaging are very important and technical limitations are related to elderly patients with tortuous and atherosclerotic vessels, anatomical variations, difficulty visualizing and catheterizing small diameter arteries feeding the prostate, and the potential risk of bladder and rectum ischemia. The use of small-diameter hydrophilic microcatheters is mandatory. Patients can be treated safely by PAE with low rates of side effects, reducing prostate volume with clinical symptoms and quality ofmore » life improvement without urinary incontinence, ejaculatory disorders, or erectile dysfunction. A multidisciplinary approach with urologists and interventional radiologists is essential to achieve better results.« less
Hybrid options for treating cardiac disease.
Umakanthan, Ramanan; Leacche, Marzia; Zhao, David X; Gallion, Anna H; Mishra, Prabodh C; Byrne, John G
2011-01-01
The options for treating heart disease have greatly expanded during the course of the last 2 1/2 decades with the advent of hybrid technology. The hybrid option for treating cardiac disease implies using the technology of both interventional cardiology and cardiac surgery to treat cardiac disease. This rapidly developing technology has given rise to new and creative techniques to treat cardiac disease involving coronary artery disease, coronary artery disease and cardiac valve disease, and atrial fibrillation. It has also led to the establishment of new procedural suites called hybrid operating rooms that facilitate the integration of technologies of interventional cardiology catheterization laboratories with those of cardiac surgery operating rooms. The development of hybrid options for treating cardiac disease has also greatly augmented teamwork and collaboration between interventional cardiologists and cardiac surgeons. Copyright © 2011 Elsevier Inc. All rights reserved.
Harrison, Christopher M; Gosai, Jivendra N
2017-04-01
Simulation-based training as an educational tool for healthcare professionals continues to grow in sophistication, scope, and usage. There have been a number of studies demonstrating the utility of the technique, and it is gaining traction as part of the training curricula for the next generation of cardiologists. In this review, we focus on the recent literature for the efficacy of simulation for practical procedures specific to cardiology, focusing on transesophageal echocardiography, cardiac catheterization, coronary angioplasty, and electrophysiology. A number of studies demonstrated improved performance by those trained using SBT when compared to other methods, although evidence of this leading to an improvement in patient outcomes remains scarce. We discuss this evidence, and the implications for practice for training in cardiology. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Hirose, Junichi; Oshima, Tomomitsu; Fujimori, Yoshiharu; Uchida, Yasumi
1993-05-01
Recent advances in fiberoptic technology enabled us to observe percutaneously the cardiac chambers and valves. We examined left ventricular luminal and valvular changes by percutaneous fiberoptic angioscopy in patients with rheumatic valvular disease. Six patients with echocardiographic rheumatic changes in the mitral valves, underwent angioscopy during routine cardiac catheterization. The fiberscope 4.2 F in diameter, and the guiding catheter 9 F in external diameter with an inflatable balloon around the distal most tip were used for angioscopy. The left ventricular endocardial surface was diffusely white in color or white and brown in mosaic fashion. Echocardiography and angiography had low sensitivity for detecting the changes of the left ventricular luminal surface. Whitish changes which were observed by angioscopy were not related to the indices derived from echocardiography and angiography. The results indicate the possibility of percutaneous angioscopy in detecting left ventricular luminal changes in patients with rheumatic valvular disease.
Addai, Theodore; Kola, Monahar; Raqeem, Muhammad Wajih; Barsamyan, Sergey; Mirrakhimov, Aibek E.
2016-01-01
An 82-year-old female with history of hyperlipidemia and hypertension presented to the clinic with chief complaint of nonradiating chest tightness accompanied by exertional dyspnea. Cardiac catheterization showed the absence of left coronary system; the entire coronary system originated from the right aortic sinus as a common trunk which then gave off the right coronary artery and the left main coronary artery. Cardiac catheterization demonstrated also another rare coronary anomaly: dual left anterior descending artery. Patient underwent percutaneous coronary intervention and subsequent multidetector computed tomography angiography confirmed the above angiography findings. Patient was subsequently discharged home on double antiplatelet therapy with aspirin and clopidogrel and has been asymptomatic since then. PMID:27293909
Barik, Ramachandra
2017-01-01
The clinical diagnosis of double chamber right ventricle (DCRV) is not straightforward. Clinical history, clinical examination, 12-lead electrocardiogram, chest X-ray, and Echocardiography (echo) contribute to morphological diagnosis. Cardiac catheterization is essential for hemodynamic evaluation. A thorough presurgical workup helps the cardiac surgeon to choose the appropriate surgical approach and timing of surgery in an individual case. We present a case of a DCRV who presented to us in the fifth decade of life. Echo confirmed the morphological diagnosis and cardiac catheterization complemented the exact pull back gradient across the obstruction in the right ventricle. This patient was suggested muscle bundle resection and ventricular septal defect closure using right atrial approach. PMID:28465983
Pinto, Cristiano José Mendes; Colombo, Roberta Cunha Rodrigues; Gallani, Maria Cecília Bueno Jayme
2006-01-01
The objective of this study was to identify, by using the Theory of Reasoned Action/Theory of Planned Behavior, the attitude and normative beliefs that influence the behavioral intention of the nurse to perform a hemodynamic assessment using the pulmonary artery catheterization. Data were collected through semi-structured interviews involving 23 nurses from three hospitals in the city of Campinas, São Paulo. The data were analyzed according to a qualitative methodology. Among the Attitude Beliefs, affective beliefs and those related to the advantages and disadvantages of performing the behavior stand out. Among the Normative Beliefs social referents were identified for the behavior, as well as the behavior-stimulating factors and the factors that discourage the performance of the behavior.
Strategies from a nationwide health information technology implementation: the VA CART story.
Box, Tamára L; McDonell, Mary; Helfrich, Christian D; Jesse, Robert L; Fihn, Stephan D; Rumsfeld, John S
2010-01-01
The VA Cardiovascular Assessment, Reporting, and Tracking (CART) system is a customized electronic medical record system which provides standardized report generation for cardiac catheterization procedures, serves as a national data repository, and is the centerpiece of a national quality improvement program. Like many health information technology projects, CART implementation did not proceed without some barriers and resistance. We describe the nationwide implementation of CART at the 77 VA hospitals which perform cardiac catheterizations in three phases: (1) strategic collaborations; (2) installation; and (3) adoption. Throughout implementation, success required a careful balance of technical, clinical, and organizational factors. We offer strategies developed through CART implementation which are broadly applicable to technology projects aimed at improving the quality, reliability, and efficiency of health care.
The role of robotic endovascular catheters in fenestrated stent grafting.
Riga, Celia V; Cheshire, Nicholas J W; Hamady, Mohamad S; Bicknell, Colin D
2010-04-01
Fenestrated stent grafting has allowed the treatment of complex thoraco-abdominal aneurysm disease via a totally endovascular approach, but the procedure can be technically challenging and time consuming. We investigated whether this procedure may be enhanced by remotely steerable robotic endovascular catheters. A four-vessel fenestrated stent graft partially deployed within a computed tomography (CT)-reconstructed pulsatile thoraco-abdominal aneurysm silicon model was used. Fifteen operators were recruited to participate in the study and divided into three groups, based on their endovascular experience: group A (n = 4, 100-200 endovascular procedures, group B (n = 5, 200-300), and group C (n = 6, >300). All operators were asked to cannulate the renal and visceral vessels under fluoroscopic guidance, using conventional and robotic techniques. Quantitative (catheterization times and wire/catheter tip movements) and qualitative metrics (procedure-specific-rating scale [IC3ST]), which grades operators on catheter use, instrumentation, successful cannulation/catheterization, and overall performance were compared. Median procedure time for cannulation of all four vessels was reduced using the robotic system (2.87 min, interquartile range [IQR; 2.20-3.90] versus 17.24 min [11.90-19.80]; P < .001) for each individual operator, regardless of the level of endovascular experience. The total number of wire/catheter movements taken to complete the task was also significantly reduced (38, IQR [29-57] versus 454 [283-687]; P < .001). There were significant differences in time and movement for cannulation of each individual vessel in the phantom. Robotic catheter operator radiation exposure was negligible as the robotic workstation is remote and away from the radiation source. Overall performance scores significantly improved using the robotic system, despite minimal operator exposure to this technology (IC3ST score 29/35, IQR [22.8-30.7] versus 19/35 [13-24.3]; P = .002). Each group of operators demonstrated an improvement in performance with robotic cannulation. For group A, median IC3ST score was 28/35, IQR (22-33) versus 15/35 (11-20); P = .04; for group B, 30/35 (27-31) versus 19/35 (18-24); P = .07; and for group C, 28.8/35 (28.5-29) versus 22/35 (16-24); P = .06. For groups B and C, these differences did not reach statistical significance. Robotic catheterization of target vessels during this procedure is feasible and minimizes radiation exposure for the operator. Steerable robotic catheters with intuitive control may overcome some of the limitations of standard catheter technology, enhance target vessel cannulation, reduce instrumentation, and improve overall performance scores.
Ballard, Dustin W; Reed, Mary E; Rauchwerger, Adina S; Chettipally, Uli K; Offerman, Steven R; Mark, Dustin G; Vinson, David R
2014-06-01
The objective was to assess clinician experience, training, and attitudes toward central venous catheterization (CVC) in adult emergency department (ED) patients in a health system promoting increased utilization of CVC for severely septic ED patients. The authors surveyed all emergency physicians (EPs) within a 21-hospital integrated health care delivery system that had recently instituted a modified Rivers protocol for providing early goal-directed therapy (EGDT) to patients with severe sepsis or septic shock, including CVC if indicated. This initiative was accompanied by a structured, but optional, systemwide hands-on training for EPs in real-time ultrasound-guided CVC (US CVC). EPs' responses to questions regarding self-reported experience with CVC in the ED are reported. Data included frequency of CVC (by type) and US CVC training opportunities: both during and after residency and informal ("on-the-job training involving actual ED patients under the oversight of someone more experienced than yourself") and formal ("off-the-job training not involving actual ED patients"). The survey also asked respondents to report their comfort levels with different types of CVC as well as their agreement with possible barriers (philosophical, time-related, equipment-related, and complication-related) to CVC in the ED. Multivariable ordinal logistic regression was used to identify provider characteristics and responses associated with higher yearly CVC volumes. The survey response rate among eligible participants was 365 of 465 (78%). Overall, 154 of 365 (42%) respondents reported performing 11 or more CVCs a year, while 46 of 365 (13%) reported doing two or fewer. Concerning CVC techniques, 271 of 358 (76%) of respondents reported being comfortable with the internal jugular approach with US guidance, compared to 200 of 345 (58%) with the subclavian approach without US. Training rates were reported as 1) in residency, formal 167 of 358 (47%) and informal 189 of 364 (52%); and 2) postresidency, formal 236 of 359 (66%) and informal 260 of 365 (71%). The most commonly self-reported barriers to CVC were procedural time (56%) and complication risk (61%). After multivariate adjustment, the following were significantly associated with greater self-reported CVC use (p < 0.01): 1) informal bedside CVC training after residency, 2) male sex, 3) disagreement with complication-related barrier questions, and 4) self-reported comfort with placing US-guided internal jugular catheters. In this cross-sectional survey-based study, EPs reported varying experience with CVC in the ED and reported high comfort with the US CVC technique. Postresidency informal training experience, male sex, negative responses to complication-related barrier questions, and comfort with placing US-guided internal jugular catheters were associated with yearly CVC volume. These results suggest that higher rates of CVC in eligible patients might be achieved by informal training programs in US and/or by disseminating existing evidence about the low risk of complications associated with the procedure. © 2014 by the Society for Academic Emergency Medicine.
... by checking it through the skin with a pulse oximeter Complete blood count (CBC) ECG (electrocardiogram) Looking at ... from the groin ( cardiac catheterization ) Transcutaneous oxygen monitor (pulse oximeter) Echo-Doppler
... Bridging Disciplines Circulation at Major Meetings Special Themed Issues Global Impact of the 2017 ACC/AHA Hypertension Guidelines Circulation Supplements Cardiovascular Case Series ECG Challenge Hospitals of History Brigham and ...
2012-01-01
Background Clinical dogma is that healthy urine is sterile and the presence of bacteria with an inflammatory response is indicative of urinary tract infection (UTI). Asymptomatic bacteriuria (ABU) represents the state in which bacteria are present but the inflammatory response is negligible. Differentiating ABU from UTI is diagnostically challenging, but critical because overtreatment of ABU can perpetuate antimicrobial resistance while undertreatment of UTI can result in increased morbidity and mortality. In this study, we describe key characteristics of the healthy and ABU urine microbiomes utilizing 16S rRNA gene (16S rDNA) sequencing and metaproteomics, with the future goal of utilizing this information to personalize the treatment of UTI based on key individual characteristics. Methods A cross-sectional study of 26 healthy controls and 27 healthy subjects at risk for ABU due to spinal cord injury-related neuropathic bladder (NB) was conducted. Of the 27 subjects with NB, 8 voided normally, 8 utilized intermittent catheterization, and 11 utilized indwelling Foley urethral catheterization for bladder drainage. Urine was obtained by clean catch in voiders, or directly from the catheter in subjects utilizing catheters. Urinalysis, urine culture and 16S rDNA sequencing were performed on all samples, with metaproteomic analysis performed on a subsample. Results A total of 589454 quality-filtered 16S rDNA sequence reads were processed through a NextGen 16S rDNA analysis pipeline. Urine microbiomes differ by normal bladder function vs. NB, gender, type of bladder catheter utilized, and duration of NB. The top ten bacterial taxa showing the most relative abundance and change among samples were Lactobacillales, Enterobacteriales, Actinomycetales, Bacillales, Clostridiales, Bacteroidales, Burkholderiales, Pseudomonadales, Bifidobacteriales and Coriobacteriales. Metaproteomics confirmed the 16S rDNA results, and functional human protein-pathogen interactions were noted in subjects where host defenses were initiated. Conclusions Counter to clinical belief, healthy urine is not sterile. The healthy urine microbiome is characterized by a preponderance of Lactobacillales in women and Corynebacterium in men. The presence and duration of NB and method of urinary catheterization alter the healthy urine microbiome. An integrated approach of 16S rDNA sequencing with metaproteomics improves our understanding of healthy urine and facilitates a more personalized approach to prevention and treatment of infection. PMID:22929533
Parsaee, Mozhgan; Ghaderi, Fereshteh; Alizadehasl, Azin; Bakhshandeh, Hooman
2016-08-01
Echocardiography is a key screening tool in the diagnostic algorithm of pulmonary hypertension (PH). In addition, tissue doppler imaging (TDI) is a promising method for the noninvasive estimation of pulmonary artery pressure (PAP). The aim of this study was to validate the accuracy of measuring the time from the beginning of the right ventricular isovolumetric contraction time (RV IVRT) to the peak of the S wave in the TDI of the base of the RV free wall (time to peak or TTP), as an indicator for the non-invasive estimation of pulmonary hypertension. In this diagnostic test study, 60 consecutive patients referred for right heart catheterization (RHC) were enrolled. A pulse-wave TDI was performed before the cardiac catheterization, with a mean interval of 1 hour between the two measurements. The TDI variables, such as the RV IVRT, myocardial performance index (MPI), and the new "time to peak" parameter, were measured at the lateral basal RV free wall. The patients were divided into two sub-groups according to the RHC findings: no-PH (mean PAP < 25 mmHg) and PH (mean PAP ≥ 25 mmHg) groups. Then, we calculated the specificity and sensitivity of the TDI parameters (including the TTP) for the diagnosis of PH. In our study, the TTP showed a significant inverse relationship with the PAP. Based on our results, a TTP of less than 127 ms could be used to predict PH, with a sensitivity and specificity of about 70% (AUC = 0.746 ± 0.064). Based on the results of this study, we suggest the use of a novel "time from the beginning of isovolumetric contraction to the peak of the S wave" (TTP) parameter in the TDI of the base of the RV free wall to predict PH with acceptable accuracy in comparison with RHC.
... possible, but depend on the extent of the heart abnormalities that accompany the pulmonary valve defect. Potential treatments include: A thin, flexible tube (heart catheterization) to repair the problem Open heart surgery ...
Risk Factors Analysis for Occurrence of Asymptomatic Bacteriuria After Endourological Procedures
Junuzovic, Dzelaludin; Hasanbegovic, Munira
2014-01-01
Introduction: Endourological procedures are performed according to the principles of aseptic techniques, jet still in certain number of patients urinary tract infections may occur. Considering the risk of urinary tract infection, there is no unique opinion about the prophylactic use of antibiotics in endourological procedures. Goal: The objective of this study was to determine the connection between endourological procedures and occurrence of urinary infections and to analyze the risk factors of urinary infection for patients who were hospitalized at the Urology Clinic of the Clinical Center University of Sarajevo CCUS. Materials and Methods: The research was conducted as a prospective study on a sample of 208 patients of both genders, who were hospitalized at the Urology Clinic of the CCUS and to whom some endourological procedure was indicated for diagnostic or therapeutic purposes. We analyzed data from patient’s histories of illness, laboratory tests taken at admission and after endourological procedures, also surgical programs for endoscopic procedures. All patients were clinically examined prior to endoscopic procedures while after the treatment attention was focused to the symptoms of urinary tract infections. Results: Statistical analysis of the tested patients indicates that there is no significant difference in the presence of postoperative, compared to preoperative bacteriuria, which implies that the endourological procedures are safe procedures in terms of urinary tract infections. Preoperatively, the most commonly isolated bacteria was Escherichia coli (30.9%) and postoperatively, Enterococcus faecalis (25%). Statistically significant effect on the occurrence of postoperative bacteriuria has preoperative bacteriuria, duration of postoperative catheterization, and duration of hospitalization. Conclusion: In everyday urological practice, it is very important to identify and control risk factors for the development of urinary infection after endourological procedures, with main objective to minimize occurrence of infectious complications. PMID:25568546
Faleiros, Fabiana; Cordeiro, Adriana; Favoretto, Naira; Käppler, Christoph; Murray, Christine; Tate, Denise
A major complication for individuals with spina bifida (SB) is managing their neurogenic bladder. For many, this process evokes negative feelings associated with guilt, dependence, and lack of self-worth. The aim of the study was to compare feelings that hinder the performing of intermittent bladder catheterization reported by individuals with SB and their families in two countries of different sociocultural characteristics: Brazil and Germany. Quantitative and comparative study with convenience sampling. The sample comprised 200 SB patients and their caregivers, 100 from Brazil and 100 from Germany. When asked about the existence of negative feelings or ideas that may hinder the performance of key person responsible for IC, 155 (77.5%) participants did not report such feelings. On the other hand, 45 (22.5%) reported emotional difficulties; among these participants, 31 (69%) were Brazilians and 14 (31%) were Germans. Although emotional factors are important to the adjustment of using IC methods for bladder management, the majority of people with SB and their caregivers seem to report no major emotional difficulties with this process. Yet a considerable group of participants did report such emotional difficulties associated with fear and shame. Knowing more about the factors associated with such negative feelings can facilitate interactions, provide mutual aid, and assist with resolution of practical concerns related to intermittent bladder catheterization.
Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M; Borm, Paul J A; Jacob, Augustinus L; Bilecen, Deniz
2009-01-01
The purpose of this study was to demonstrate first magnetic resonance (MR)-guided stenting of iliac and supraaortic arteries using a polyetheretherketone-based (PEEK) MR-compatible guide wire. In vitro and animal experiments were performed in a short magnet wide-bore scanner (1.5 Tesla, Espree, Siemens Healthcare, Erlangen, Germany). For all experiments, a 0.035'' MR-compatible guide wire prototoype was used. This wire had a compound core of PEEK with reinforcing fibres, a soft and atraumatic tip and a hydrophilic coating. For its passive visualization, paramagnetic markings were attached. All experiments were performed through a vascular introducer sheath under MR-guidance. In vitro repetitive selective over the wire catheterizations of either the right carotid artery and the left subclavian artery were performed. In vivo, selective catheterization and over-the-wire stenting of the brachiocephalic trunk and the left subclavian artery were performed. The common iliac arteries were catheterized retrogradely (left) and cross-over (right). Angioplasty and stenting were performed over-the-wire. All procedures were successful. Visibility of the PEEK-based guide-wire was rated good in vitro and acceptable in vivo. Guide wire pushability and endovascular device support were good. The PEEK-based MR-compatible guide wire is well visible and usable under MR-guidance. It supports over-the-wire treatment of iliac arteries and supraaortic arteries.
Konstantinou, Evangelos A; Stafylarakis, Emmanuil; Kapritsou, Maria; Mitsos, Aristotelis P; Fotis, Theofanis G; Kiekkas, Panagiotis; Mariolis-Sapsakos, Theodoros; Argyras, Eriphyli; Nomikou, Irini Th; Dimitrakopoulos, Antonios
2012-09-01
Placement of peripherally inserted central catheters (PICCs), definitely offers a clear advantage over any other method regarding central venous catheterization. Its ultrasonographic orientation enhances significantly its accuracy, safety and efficacy, making this method extremely comfortable for the patient who can continue his or her therapy even in an outpatient basis. We present the first reported case of a PICCS insertion in Greece, which has been performed by a university-degree nurse. The aim of this review of literature was to present the evolution in nursing practice in Greece. A PICC was inserted in a 77-year-old male patient suffering from a recent chemical pneumonia with a history of Alzheimer's disease. A description of all the technical details of this insertion is reported, focusing on the pros and cons of the method and a thorough review of the history and advances in central venous catheterization throughout the years is also presented. PICCs provide long-term intravenous access and facilitate the delivery of extended antibiotic therapy, chemotherapy and total parenteral nutrition. We strongly believe that PICCs are the safest and most effective method of peripherally inserted central venous catheterization. Larger series are necessary to prove the above hypothesis, and they are under construction by our team. Copyright © 2012 Society for Vascular Nursing, Inc. Published by Mosby, Inc. All rights reserved.
Nurses' training and confidence on deep venous catheterization.
Liachopoulou, A P; Synodinou-Kamilou, E E; Deligiannidi, P G; Giannakopoulou, M; Birbas, K N
2008-01-01
The rough estimation of the education and the self-confidence of nurses, both students and professionals, regarding deep venous catheterization in adult patients, the evaluation of the change in self-confidence of one team of students who were trained with a simulator on deep venous catheterization and the correlation of their self-confidence with their performance recorded by the simulator. Seventy-six nurses and one hundred twenty-four undergraduate students participated in the study. Fourty-four University students took part in a two-day educational seminar and were trained on subclavian and femoral vein paracentesis with a simulator and an anatomical model. Three questionnaires were filled in by the participants: one from nurses, one from students of Technological institutions, while the University students filled in the previous questionnaire before their attendance of the seminar, and another questionnaire after having attended it. Impressive results in improving the participants' self-confidence were recorded. However, the weak correlation of their self-confidence with the score automatically provided by the simulator after each user's training obligates us to be particularly cautious about the ability of the users to repeat the action successfully in a clinical environment. Educational courses and simulators are useful educational tools that are likely to shorten but in no case can efface the early phase of the learning curve in clinical setting, substituting the clinical training of inexperienced users.
Kaviani, Nasser; Shahtusi, Mina; Haj Norousali Tehrani, Maryam; Nazari, Sara
2014-09-01
Premedication is expedient in reducing the psychological trauma from recalling the unpleasant pre-anesthetic phases, hence, inducing a trouble-free anesthesia. This study aimed to determine the effectiveness of oral midazolam in co-operation of the subjects before general anesthesia and in recalling the pre-anesthetic phases, performed on children candidate for dental treatment under general anesthesia. In this prospective clinical trial study, 62 healthy non-cooperative children, candidate for dental treatment under general anesthesia, were randomly divided into study and control groups. The children received 20ml orange juice, 20 minutes before starting the anesthesia. The juice of the test group contained 0.5mg/kg of midazolam and that of the control group included no medication. The induction and the maintenance process of anesthesia were similar in both groups. The manner of subjects when separated from parents, their cooperation during intravenous catheterization, and recalling the pre-anesthetic events were recorded. Data were analyzed by adopting chi-square and Mann-Whitney tests. Most of the children in the test group had a comfortable separation from parents, restful IV catheterization and 90% of the subjects did not recall the pre-anesthetic events. Under the circumstances of this study, it could be concluded that 0.5mg/kg oral midazolam premedication is effective for comfortable separation of children from parents and restful IV catheterization and also forgetting the pre-anesthetic events.
... cardiologists who specialize in arrhythmias. Medical and Family Histories To diagnose an arrhythmia, your doctor may ask ... your doctor will use a procedure called cardiac catheterization (KATH-e-ter-ih-ZA-shun). A thin, ...
What to Expect during Cardiac Catheterization
... Bridging Disciplines Circulation at Major Meetings Special Themed Issues Global Impact of the 2017 ACC/AHA Hypertension Guidelines Circulation Supplements Cardiovascular Case Series ECG Challenge Hospitals of History Brigham and ...
Kachko, Ludmyla; Ben Ami, Shiri; Liberman, Alon; Birk, Einat; Kronenberg, Sefi
2011-01-01
In the United States, duloxetine has been approved for the treatment of major depressive disorder, diabetic peripheral neuropathic pain and fibromyalgia in the adult population. Data regarding the use of duloxetine in the pediatric population, however, are very limited. Femoral nerve injury is a rare complication of cardiac catheterization. In the case described, duloxetine contributed to a successful multimodal treatment program for peripheral neuropathic pain due to femoral neuropathy in an adolescent with 'reactive depression' and conversion symptoms. To the best of the authors' knowledge, the present article is only the third such report on this dual use of duloxetine in children and adolescents, and the first report of such treatment following femoral neuropathy induced by cardiac catheterization.
Percutaneous coil embolization of massive pelvic pseudoaneurysm in an infant.
Lillis, Anna P; Shaikh, Raja; Alomari, Ahmad I; Chaudry, Gulraiz
2015-06-01
Iatrogenic pseudoaneurysm formation is an uncommon but potentially serious complication of cardiac catheterization. This case report describes diagnosis and treatment of a large left external iliac artery pseudoaneurysm in a 3-month-old boy following cardiac catheterization and aortic balloon dilatation for aortic coarctation. A 4-cm pulsatile mass in the left hemipelvis was discovered on MRI performed 6 weeks later for possible tethered spinal cord. Sonography and angiography showed a large pseudoaneurysm of the left external iliac artery just distal to the iliac bifurcation with no flow in the external iliac artery distal to the pseudoaneurysm. Percutaneous US-guided thrombin injection was performed twice, with partial recanalization after each treatment. The residual portion of the pseudoaneurysm was then successfully embolized with percutaneous coils deployed under US and fluoroscopic guidance.
Intraperitoneally placed Foley catheter via verumontanum initially presenting as a bladder rupture.
Raheem, Omer A; Jeong, Young Beom
2011-09-01
Since urethral Foley catheterization is usually easy and safe, serious complications related to this procedure have been rarely reported. Herein, we describe a case of intraperitoneally placed urethral catheter via verumontanum presenting as intraperitoneal bladder perforation in a chronically debilitated elderly patient. A 82-yr-old male patient was admitted with symptoms of hematuria, lower abdominal pain after traumatic Foley catheterization. The retrograde cystography showed findings of intraperitoneal bladder perforation, but emergency laparotomy with intraoperative urethrocystoscopy revealed a tunnel-like false passage extending from the verumontanum into the rectovesical pouch between the posterior wall of the bladder and the anterior wall of the rectum with no bladder injury. The patient was treated with simple closure of the perforated rectovesical pouch and a placement of suprapubic cystostomy tube.
A successful model to learn and implement ultrasound-guided venous catheterization in apheresis.
Gopalasingam, Nigopan; Thomsen, Anna-Marie Eller; Folkersen, Lars; Juhl-Olsen, Peter; Sloth, Erik
2017-12-01
Apheresis treatments can be performed with peripheral venous catheters (PVC), although central venous catheters (CVC) are inserted when PVCs fail or patient with history of difficult vascular access prior to the apheresis. Ultrasound guidance for PVC has shown promising results in other settings. To investigate if ultrasound guidance for PVC could be implemented among apheresis nurses. Second, how implementation of ultrasound guidance affected the number of CVCs used for apheresis per patient. Apheresis nurses completed a systematic training program for ultrasound-guided vascular access. All independent catheterizations were registered during the implementation stage. The number of CVCs in the pre- and postimplementation stages of the ultrasound guidance was compared. Six nurses completed the training program within a median of 48 days (range 38-83 days). In 77 patients, 485 independent ultrasound-guided PVC placements were performed during the implementation stage. All apheresis treatments (485/485) were accomplished using PVCs without requiring CVC as rescue. During the preimplementation stage, 125 of 273 (45.8%) procedures required a CVC for completion of apheresis procedures; during the postimplementation stage only 30 of 227 (13.2%) procedures required a CVC (p < 0.001). In the postimplementation stage, no CVCs were placed as rescue caused by failed PVCs but were only placed for patients where the ultrasound machine was unavailable. It indicates an effective success rate of 100% for ultrasound-guided PVC use. This study showed that ultrasound guidance could be implemented among apheresis nurses as a routine tool eliminating the need of CVC as a rescue. © 2017 Wiley Periodicals, Inc.
Uchita, S; Matsuo, K; Ishida, T; Okajima, Y; Aotsuka, H; Fujiwara, T
1998-11-01
We report a two-year-old girl with asplenia, [A, L, L] DORV, pulmonary atresia, common AV valve, PDA, and TAPVC, who successfully underwent total cavo pulmonary connection (TCPC). Deep cyanosis was pointed out since birth. Cardiac catheterization performed on the sixth day after birth revealed a diminutive pulmonary artery tree of which PA index was 41 mm2/m2. Left modified Blalock-Taussig shunt was created at 27 days of age. The PA index increased to 282 mm2/mm2, but disparity in diameter between the left and the right pulmonary artery was yielded by PDA subsidence. Therefore additional contralateral B-T shunt was made at one year of age. Follow-up cardiac catheterization at 28 months of age showed well developed pulmonary artery; PA index of 460 mm2/m2, right pulmonary resistance (Rp) of 3.49 units, left Rp of 2.33 units, and estimated total Rp was 1.39. According to study, bidirectional Glenn procedure or TCPC was indicated. Considering necessity of urgent repair of common pulmonary vein obstruction, regurgitation of the common atrio-ventricular valve and pulmonary artery stenosis, TCPC was performed with concomitant repair of the associated lesions. Severe butterfly-figure stenosis of the central PA was augmented by anastomosing both the left SVC and the left-sided atrium. In conclusion, diminutive pulmonary artery could be adequately grown by phase-in Blalock-Taussig shunts. Pulmonary blood flow scintigraphy was thought to be useful for estimation of pulmonary resistance in such cases with different pulmonary resistance between right and left PA.
Chen, Y; Wu, W; Zhang, X; Fan, W; Shen, L
2011-01-01
Purpose To investigate the feasibility of bypassing occluded segments of retinal venous main vessels in isolated, arterially perfused caprine eyes via the closed-sky vitrectomy approach using keratoprosthesis. Methods Isolated caprine eyes were used in this study. For each eye, the retinal vessel was perfused by Krebs solution via ophthalmic artery, and pars plana vitrectomy was performed using temporary keratoprosthesis. All retinal micro-vascular maneuvers were performed in a closed-sky eyeball. The main retinal vein was blocked by endodiathermy at the site of the vessel's first branching. Two openings, several millimeters apart, were created by vascular punctures in both the main vein and its branch vein wall straddling the induced occluded segment. Catheterization was achieved using a flexible polyimide tube, with each end inserted into the vessel wall opening. A sealed connection between the vessel and the tube was obtained by endodiathermy. Bypass of the occluded retinal vein segment was thus achieved, and the patency of this vascular bypass was confirmed by intravascular staining. Results Puncturing, catheterization, and endodiathermy were viable by closed-sky approach using keratoprosthesis. Bypassing of the occluded retinal main vein segment was accomplished with the combination of these maneuvers. Good results were obtained in 23 of 38 (60%) caprine eyes. Conclusions This study demonstrated that bypassing the occluded segment of retinal main vein can be successfully performed in a closed-sky eyeball model of isolated, arterially perfused caprine eye. This early work indicated that the more advanced retinal vascular bypass surgery in in vivo eye may be feasible in the future. PMID:21921946
Smartphone ECG for evaluation of STEMI: results of the ST LEUIS Pilot Study.
Muhlestein, Joseph Boone; Le, Viet; Albert, David; Moreno, Fidela Ll; Anderson, Jeffrey L; Yanowitz, Frank; Vranian, Robert B; Barsness, Gregory W; Bethea, Charles F; Severance, Harry W; Ramo, Barry; Pierce, John; Barbagelata, Alejandro; Muhlestein, Joseph Brent
2015-01-01
12-lead ECG is a critical component of initial evaluation of cardiac ischemia, but has traditionally been limited to large, dedicated equipment in medical care environments. Smartphones provide a potential alternative platform for the extension of ECG to new care settings and to improve timeliness of care. To gain experience with smartphone electrocardiography prior to designing a larger multicenter study evaluating standard 12-lead ECG compared to smartphone ECG. 6 patients for whom the hospital STEMI protocol was activated were evaluated with traditional 12-lead ECG followed immediately by a smartphone ECG using right (VnR) and left (VnL) limb leads for precordial grounding. The AliveCor™ Heart Monitor was utilized for this study. All tracings were taken prior to catheterization or immediately after revascularization while still in the catheterization laboratory. The smartphone ECG had excellent correlation with the gold standard 12-lead ECG in all patients. Four out of six tracings were judged to meet STEMI criteria on both modalities as determined by three experienced cardiologists, and in the remaining two, consensus indicated a non-STEMI ECG diagnosis. No significant difference was noted between VnR and VnL. Smartphone based electrocardiography is a promising, developing technology intended to increase availability and speed of electrocardiographic evaluation. This study confirmed the potential of a smartphone ECG for evaluation of acute ischemia and the feasibility of studying this technology further to define the diagnostic accuracy, limitations and appropriate use of this new technology. Copyright © 2015 Elsevier Inc. All rights reserved.
Liu, Jie; Fei, Lei; Huang, Guang-Qing; Shang, Xiao-Ke; Liu, Mei; Pei, Zhi-Jun; Zhang, Yong-Xue
2018-05-01
Right heart catheterization is commonly used to measure right ventricle hemodynamic parameters and is the gold standard for pulmonary arterial hypertension diagnosis; however, it is not suitable for patients' long-term follow-up. Non-invasive echocardiography and nuclear medicine have been applied to measure right ventricle anatomy and function, but the guidelines for the usefulness of clinical parameters remain to be established. The goal of this study is to identify reliable clinical parameters of right ventricle function in pulmonary arterial hypertension patients and analyze the relationship of these clinical parameters with the disease severity of pulmonary arterial hypertension. In this study, 23 normal subjects and 23 pulmonary arterial hypertension patients were recruited from January 2015 to March 2016. Pulmonary arterial hypertension patients were classified into moderate and severe pulmonary arterial hypertension groups according to their mean pulmonary arterial pressure levels. All the subjects were subjected to physical examination, chest X-ray, 12-lead electrocardiogram, right heart catheterization, two-dimensional echocardiography, and technetium 99m ( 99m Tc) myocardial perfusion imaging. Compared to normal subjects, the right heart catheterization indexes including right ventricle systolic pressure, right ventricle end diastolic pressure, pulmonary artery systolic pressure, pulmonary artery diastolic pressure, pulmonary vascular resistance, and right ventricle end systolic pressure increased in pulmonary arterial hypertension patients and were correlated with mean pulmonary arterial pressure levels. Echocardiography parameters, including tricuspid regurgitation peak velocity, tricuspid regurgitation pressure gradient, tricuspid annular plane systolic excursion and fractional area, right ventricle-myocardial performance index, were significantly associated with the mean pulmonary arterial pressure levels in pulmonary arterial hypertension patients. Furthermore, myocardial perfusion imaging was not observed in the normal subjects but in pulmonary arterial hypertension patients, especially severe pulmonary arterial hypertension subgroup, and showed potential diagnostic properties for pulmonary arterial hypertension. In conclusion, mean pulmonary arterial pressure levels are correlated with several right heart catheterization and echocardiography markers in pulmonary arterial hypertension patients; echocardiography and 99m Tc myocardial perfusion can be used to evaluate right ventricle performance in pulmonary arterial hypertension patients. Impact statement In this study, we analyzed the clinical parameters for evaluating RV function, including right ventricle catheterization (RHC), echocardiography, and technetium 99m ( 99m Tc) myocardial perfusion imaging (MPI) in normal Asian subjects and PAH patients ( n = 23 for each group). Our results demonstrated that six RHC indexes, four echocardiography indexes and MPI index were significantly altered in PAH patients and correlated with the levels of mean pulmonary arterial pressure. Importantly, we evaluated the diagnostic performance of MPI and found that MPI has a strong diagnostic accuracy in PAH patients. The findings from this study will be of interest to clinical investigators who make diagnosis and therapeutic strategies for PAH patients.
... eds. Rutherford's Vascular Surgery . 8th ed. Philadelphia, PA: Elsevier Saunders; 2014:chap 102. Goldstein LB. Approach to ... eds. Goldman's Cecil Medicine . 25th ed. Philadelphia, PA: Elsevier Saunders; 2016:chap 406. Kern M. Catheterization and ...
Cardiac Catheterization (For Teens)
... FrameworkServlet.doGet(FrameworkServlet.java:549) at javax.servlet.http.HttpServlet.service(HttpServlet.java:617) at javax.servlet.http.HttpServlet.service(HttpServlet.java:717) at org.apache. ...
... insert your catheter: Wash your hands well with soap and water. Collect your supplies, including your catheter ( ... penis with Betadine (an antiseptic cleaner), a towelette, soap and water, or baby wipes the way your ...
... and Their Families , ATS Website: www.thoracic.org/assemblies/cc/ccprimer/mainframe2.html Additional Information American Thoracic ... Have the ICU nurse show you how the line is bandaged and how it is watched to ...
Semiotics and semiology of Nursing: evaluation of undergraduate students' knowledge on procedures.
Melo, Gabriela de Sousa Martins; Tibúrcio, Manuela Pinto; Freitas, Camylla Cavalcante Soares de; Vasconcelos, Quinídia Lúcia Duarte de Almeida Quithé de; Costa, Isabel Karolyne Fernandes; Torres, Gilson de Vasconcelos
2017-04-01
to assess the knowledge of scholars on Nursing regarding simple hands hygiene (SHH), blood pressure measurement (BP), peripheral venipuncture (PV) with venous catheter and male urethral catheterization delay (UCD) procedures. quantitative study carried out between February and May 2014, with 186 undergraduate Nursing students from 5th to 9th period of a public university of Rio Grande do Norte, with application of four questionnaires. One carried out descriptive and analytic analysis. the students presented low average percentage of right answers, especially in blood pressure measurement (55.5%); SHH's average was higher than 70%. The average of correct answers was the highest in SHH (8.6), followed by UCD (7.8), PV (7.4) and BP (6.7). The questions regarding the topic "concepts" showed less correct answers when comparing it to the topic "technique steps". it is necessary to establish knowledge monitoring strategies, in order to stimulate the constant improvement.
The rise of cardiovascular medicine†
Braunwald, Eugene
2012-01-01
Modern cardiology was born at the turn of the nineteenth to twentieth centuries with three great discoveries: the X ray, the sphygmomanometer, and the electrocardiograph. This was followed by cardiac catheterization, which led to coronary angiography and to percutaneous coronary intervention. The coronary care units and early reperfusion reduced the early mortality owing to acute myocardial infarction, and the discovery of coronary risk factors led to the development of Preventive Cardiology. Other major advances include several cardiac imaging techniques, the birth and development of cardiac surgery, and the control of cardiac arrhythmias. The treatment of heart failure, although greatly improved, remains a challenge. Current cardiology practice is evidence-based and global in scope. Research and practice are increasingly conducted in cardiovascular centres and institutes. It is likely that in the future, a greater emphasis will be placed on prevention, which will be enhanced by genetic information. PMID:22416074
Brennand, Erin A; Kim-Fine, Shunaha
2016-08-15
The goal of this trial is to compare two techniques for tensioning retropubic midurethral slings: a Mayo scissor between the tape and urethra vs. a Babcock clamp creating a measured loop underneath the urethra. The primary outcome is a composite of abnormal bladder function at 12 months post surgery. Abnormal bladder function is defined as bothersome stress incontinence or worsening over active bladder symptoms, a positive cough stress test, re-treatment of stress urinary incontinence, post-operative urinary retention requiring either catheterization beyond 6 weeks or surgical intervention. Secondary outcomes include the duration of post operative urinary retention, quality of life scores, and physical examination. This article describes the rationale and design of this clinical trial, which will be of interest to those who care for patient with pelvic floor disorders such as stress urinary incontinence.
Transesophageal Doppler measurement of renal arterial blood flow velocities and indices in children.
Zabala, Luis; Ullah, Sana; Pierce, Carol D'Ann; Gautam, Nischal K; Schmitz, Michael L; Sachdeva, Ritu; Craychee, Judith A; Harrison, Dale; Killebrew, Pamela; Bornemeier, Renee A; Prodhan, Parthak
2012-06-01
Doppler-derived renal blood flow indices have been used to assess renal pathologies. However, transesophageal ultrasonography (TEE) has not been previously used to assess these renal variables in pediatric patients. In this study, we (a) assessed whether TEE allows adequate visualization of the renal parenchyma and renal artery, and (b) evaluated the concordance of TEE Doppler-derived renal blood flow measurements/indices compared with a standard transabdominal renal ultrasound (TAU) in children. This prospective cohort study enrolled 28 healthy children between the ages of 1 and 17 years without known renal dysfunction who were undergoing atrial septal defect device closure in the cardiac catheterization laboratory. TEE was used to obtain Doppler renal artery blood velocities (peak systolic velocity, end-diastolic velocity, mean diastolic velocity, resistive index, and pulsatility index), and these values were compared with measurements obtained by TAU. Concordance correlation coefficient (CCC) was used to determine clinically significant agreement between the 2 methods. The Bland-Altman plots were used to determine whether these 2 methods agree sufficiently to be used interchangeably. Statistical significance was accepted at P ≤ 0.05. Obtaining 2-dimensional images of kidney parenchyma and Doppler-derived measurements using TEE in children is feasible. There was statistically significant agreement between the 2 methods for all measurements. The CCC between the 2 imaging techniques was 0.91 for the pulsatility index and 0.66 for the resistive index. These coefficients were sensitive to outliers. When the highest and lowest data points were removed from the analysis, the CCC between the 2 imaging techniques was 0.62 for the pulsatility index and 0.50 for the resistive index. The 95% confidence interval (CI) for pulsatility index was 0.35 to 0.98 and for resistive index was 0.21 to 0.89. The Bland-Altman plots indicate good agreement between the 2 methods; for the pulsatility index, the limits of agreement were -0.80 to 0.53. The correlation of the size of the measurement and the mean difference in methods (-0.14; 95% CI = -0.28, 0.01) was not statistically significant (r = 0.31, P = 0.17). For the resistive index, the limits of agreement were -0.22 to 0.12. The correlation of the size of the measurement and the mean difference in methods (-0.05; 95% CI = -0.09, -0.01) was not statistically significant (r = 0.10, P = 0.65). This study confirms the feasibility of obtaining 2-dimensional images of kidney parenchyma and Doppler-derived measurements using TEE in children. Angle-independent TEE Doppler-derived indices show significant concordance with those derived by TAU. Further studies are required to assess whether this correlation holds true in the presence of renal pathology. This technique has the potential to help modulate intraoperative interventions based on their impact on renal variables and may prove helpful in the perioperative period for children at risk of acute kidney injury.
What Is Cardiac Catheterization?
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Catheterization • Urinary Tract Infections: Indwelling (Foley) Catheter Bladder Management [ Download this pamphlet: "Bladder Management" - (PDF, 499KB) ] The ... and medication or surgery may be helpful. Bladder Management Foley or Suprapubic Catheter A tube is inserted ...
Duration and Adverse Events of Non-cuffed Catheter in Patients With Hemodialysis
2014-10-09
Renal Failure Chronic Requiring Hemodialysis; Central Venous Catheterization; Inadequate Hemodialysis Blood Flow; Venous Stenosis; Venous Thrombosis; Infection Due to Central Venous Catheter; Central Venous Catheter Thrombosis
Hager, W David; Collins, Irina; Tate, Janet P; Azrin, Michael; Foley, Raymond; Lakshminarayanan, Santha; Rothfield, Naomi F
2013-07-01
The cause for shortness of breath among systemic sclerosis (SSc) patients is often lacking. We sought to characterize the hemodynamics of these patients by using simple isotonic arm exercise during cardiac catheterization. Catheterization was performed in 173 SSc patients when resting echocardiographic pulmonary systolic pressures were <40 but >40 mmHg post stress. Patients with resting mean pulmonary arterial pressures (mPAP) ≤ 25 and pulmonary arterial wedge pressures (PAWP) ≤ 15 mmHg exercised with 1-pound hand weights. Normal exercise was defined as a change in mPAP divided by the change in cardiac output (CO) (ΔmPAP/ΔCO) ratio ≤ 2 for patients <50 years (≤3 for >50). An abnormal ΔmPAP/ΔCO ratio, an exercise transpulmonary gradient (TPG) ≥ 15, a PAWP < 20, a ΔTPG > ΔPAWP and a pulmonary vascular resistance (PVR) which increased defined exercise-induced pulmonary arterial hypertension (EIPAH). An abnormal ΔmPAP/ΔCO ratio, an exercise TPG < 15, a PAWP ≥ 20, a ΔTPG < ΔPAWP and a drop in PVR defined left ventricular diastolic dysfunction (DD). Twelve patients without SSc served as controls. Pulmonary pressures increased with exercise in 53 patients. Six had EIPAH and 47 had DD. With exercise, mPAP and PAWP were 20 ± 4 and 13 ± 2 in controls, 36 ± 3 and 12 ± 4 in EIPAH and 34 ± 6 and 26 ± 4 in DD. Control ΔmPAP/ΔCO was 0.8 ± 0.7, 7.5 ± 3.9 in EIPAH and 9.1 ± 7.2 in DD. Rest and exercise TPG was normal for control and DD patients but increased (12 ± 4 to 23 ± 4) in EIPAH (P < 0.0001). PVR decreased in DD but increased in EIPAH with exercise. Exercise during catheterization elucidates the pathophysiology of dyspnea and distinguishes EIPAH from the more common DD in SSc patients. © 2012 John Wiley & Sons Ltd.
Losey, Aaron D.; Lillaney, Prasheel; Martin, Alastair J.; Cooke, Daniel L.; Wilson, Mark W.; Thorne, Bradford R. H.; Sincic, Ryan S.; Arenson, Ronald L.; Saeed, Maythem
2014-01-01
Purpose To compare in vitro navigation of a magnetically assisted remote-controlled (MARC) catheter under real-time magnetic resonance (MR) imaging with manual navigation under MR imaging and standard x-ray guidance in endovascular catheterization procedures in an abdominal aortic phantom. Materials and Methods The 2-mm-diameter custom clinical-grade microcatheter prototype with a solenoid coil at the distal tip was deflected with a foot pedal actuator used to deliver 300 mA of positive or negative current. Investigators navigated the catheter into branch vessels in a custom cryogel abdominal aortic phantom. This was repeated under MR imaging guidance without magnetic assistance and under conventional x-ray fluoroscopy. MR experiments were performed at 1.5 T by using a balanced steady-state free precession sequence. The mean procedure times and percentage success data were determined and analyzed with a linear mixed-effects regression analysis. Results The catheter was clearly visible under real-time MR imaging. One hundred ninety-two (80%) of 240 turns were successfully completed with magnetically assisted guidance versus 144 (60%) of 240 turns with nonassisted guidance (P < .001) and 119 (74%) of 160 turns with standard x-ray guidance (P = .028). Overall mean procedure time was shorter with magnetically assisted than with nonassisted guidance under MR imaging (37 seconds ± 6 [standard error of the mean] vs 55 seconds ± 3, P < .001), and time was comparable between magnetically assisted and standard x-ray guidance (37 seconds ± 6 vs 44 seconds ± 3, P = .045). When stratified by angle of branch vessel, magnetic assistance was faster than nonassisted MR guidance at turns of 45°, 60°, and 75°. Conclusion In this study, a MARC catheter for endovascular navigation under real-time MR imaging guidance was developed and tested. For catheterization of branch vessels arising at large angles, magnetically assisted catheterization was faster than manual catheterization under MR imaging guidance and was comparable to standard x-ray guidance. © RSNA, 2014 Online supplemental material is available for this article. PMID:24533872
Gaudino, Mario; Leone, Alessandro; Lupascu, Andrea; Toesca, Amelia; Mazza, Andrea; Ponziani, Francesca Romana; Flore, Roberto; Tondi, Paolo; Massetti, Massimo
2015-09-01
To assess the degree of damage to the radial artery (RA) in coronary artery bypass grafting (CABG) patients who underwent preoperative transradial coronary angiography (RA-CA). From May 2012 to October 2013, 50 consecutive CABG patients who underwent RA-CA were prospectively enrolled in the study. All patients underwent echo-Doppler evaluation of the RA of the catheterized arm; the contralateral RA was used as control. The distal segment of the RA was submitted to immunohistochemical assessment of endothelial integrity. Patients were divided in three groups according to the time interval from angiography to evaluation: ≤24 h, >24 h to <7 days and ≥7 days. Baseline RA median diameters were 0.25 ± 0.04 cm in the cannulated arm and 0.22 ± 0.04 cm in the non-cannulated arm (P = 0.01). The flow-mediated dilatation (FMD) in the RA in the catheterized arm and in the control arm were 11.6 ± 7.9 and 14.2 ± 8.9 (P = 0.01), respectively. A statistically significant correlation was found between FMD of the catheterized RA and the time from RA-CA (Pearson's r = 0.348). Linear regression analysis confirmed that the FMD of the catheterized RA was dependent on days elapsed from the procedure (P = 0.032; OR 1.11, CI 0.009-0.203). Immunohistochemical evaluation showed extensive endothelial lesion in all examined RAs, with a trend towards reduction of the damage with time. Endothelial function and integrity of the cannulated arm did not reach those of the control arm in any of the study patients. RA-CA produces extensive damage to the RA. The lesions tend to heal with time but incomplete recovery of endothelial integrity and function is still present more than 30 days after the procedure. After RA-CA, the cannulated RA should not be used for CABG. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
The training and learning process of transseptal puncture using a modified technique.
Yao, Yan; Ding, Ligang; Chen, Wensheng; Guo, Jun; Bao, Jingru; Shi, Rui; Huang, Wen; Zhang, Shu; Wong, Tom
2013-12-01
As the transseptal (TS) puncture has become an integral part of many types of cardiac interventional procedures, its technique that was initial reported for measurement of left atrial pressure in 1950s, continue to evolve. Our laboratory adopted a modified technique which uses only coronary sinus catheter as the landmark to accomplishing TS punctures under fluoroscopy. The aim of this study is prospectively to evaluate the training and learning process for TS puncture guided by this modified technique. Guided by the training protocol, TS puncture was performed in 120 consecutive patients by three trainees without previous personal experience in TS catheterization and one experienced trainer as a controller. We analysed the following parameters: one puncture success rate, total procedure time, fluoroscopic time, and radiation dose. The learning curve was analysed using curve-fitting methodology. The first attempt at TS crossing was successful in 74 (82%), a second attempt was successful in 11 (12%), and 5 patients failed to puncture the interatrial septal finally. The average starting process time was 4.1 ± 0.8 min, and the estimated mean learning plateau was 1.2 ± 0.2 min. The estimated mean learning rate for process time was 25 ± 3 cases. Important aspects of learning curve can be estimated by fitting inverse curves for TS puncture. The study demonstrated that this technique was a simple, safe, economic, and effective approach for learning of TS puncture. Base on the statistical analysis, approximately 29 TS punctures will be needed for trainee to pass the steepest area of learning curve.