Comparison of electro and chemical cautery in the treatment of anterior epistaxis.
Toner, J G; Walby, A P
1990-08-01
In the ENT Department of the Royal Victoria Hospital, Belfast, the impression (supported only by anecdotes) was that electro-cautery was superior to chemical cautery in the treatment of simple anterior epistaxis. Since no evaluation of the relative merits of electro and chemical cautery has been reported, a prospective randomized study was conducted to assess the effectiveness of electro-cautery and cautery with silver nitrate. The results of the study showed that there was no statistically significant difference between the two methods in either controlling the epistaxis or in the incidence of complications. It is concluded that since cautery with a silver nitrate tipped applicator is simpler, and of equal effectiveness, it would appear to be the treatment of choice for simple anterior epistaxis.
21 CFR 886.4100 - Radiofrequency electrosurgical cautery apparatus.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency electrosurgical cautery apparatus. 886.4100 Section 886.4100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... electrosurgical cautery apparatus. (a) Identification. A radiofrequency electrosurgical cautery apparatus is an AC...
21 CFR 886.4100 - Radiofrequency electrosurgical cautery apparatus.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Radiofrequency electrosurgical cautery apparatus. 886.4100 Section 886.4100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... electrosurgical cautery apparatus. (a) Identification. A radiofrequency electrosurgical cautery apparatus is an AC...
21 CFR 886.4115 - Thermal cautery unit.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4115 Thermal cautery unit. (a) Identification. A thermal cautery unit is an AC-powered or battery-powered device intended for use during ocular surgery to... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Thermal cautery unit. 886.4115 Section 886.4115...
21 CFR 886.4115 - Thermal cautery unit.
Code of Federal Regulations, 2012 CFR
2012-04-01
...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4115 Thermal cautery unit. (a) Identification. A thermal cautery unit is an AC-powered or battery-powered device intended for use during ocular surgery to... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Thermal cautery unit. 886.4115 Section 886.4115...
21 CFR 886.4115 - Thermal cautery unit.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4115 Thermal cautery unit. (a) Identification. A thermal cautery unit is an AC-powered or battery-powered device intended for use during ocular surgery to... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Thermal cautery unit. 886.4115 Section 886.4115...
21 CFR 886.4115 - Thermal cautery unit.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4115 Thermal cautery unit. (a) Identification. A thermal cautery unit is an AC-powered or battery-powered device intended for use during ocular surgery to... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Thermal cautery unit. 886.4115 Section 886.4115...
21 CFR 886.4115 - Thermal cautery unit.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4115 Thermal cautery unit. (a) Identification. A thermal cautery unit is an AC-powered or battery-powered device intended for use during ocular surgery to... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Thermal cautery unit. 886.4115 Section 886.4115...
Johnson, Nathan; Faria, John; Behar, Philomena
2015-11-01
To compare the outcome of children with anterior epistaxis treated intraoperatively with either bipolar electrocautery or silver nitrate chemical cautery. Case series with chart review. Tertiary-care pediatric otolaryngology practice. Children aged 2 to 18 years treated with either intraoperative bipolar electrocautery or silver nitrate chemical cautery of the anterior nasal septum for recurrent anterior epistaxis. Any reported bleeding event after surgery was recorded. The mean time from surgery to recurrent epistaxis was compared between groups. Fifty patients underwent bipolar electrocautery, while 60 patients underwent silver nitrate chemical cautery. Within 2 years, 1 (2%) patient in the bipolar electrocautery group and 13 (22%) patients in the silver nitrate chemical cautery group had recurrent epistaxis (P = .003). Two years after treatment, there was no difference between treatment groups. Overall, 4 patients (8%) had recurrent epistaxis postoperatively in the bipolar electrocautery group at a mean of 4.34 years after treatment, while 17 (28.3%) patients recurred after a mean of 1.53 years of treatment in the silver nitrate chemical cautery group (P = .01). Compared to those treated with chemical cautery, those treated with bipolar electrocautery had a longer nosebleed-free period and a lower incidence of recurrent epistaxis within 2 years of treatment. Beyond 2 years, the treatment methods are equivocal. Bipolar electrocautery may be a superior treatment in children who will not tolerate in-office chemical cautery, in those with a risk of severe bleeding, or when it can be combined with other operative procedures. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.
[Steam cautery of the cornea in microbial keratitis].
Maier, P; Birnbaum, F; Reinhard, T
2008-01-01
In some cases topical antimicrobial treatment of microbial keratitis or corneal ulcers remains unsuccessful, with increasing infiltration of the corneal stroma. In this situation the steam cautery procedure developed by Karl Wessely in 1911 can lead to rapid healing of the inflammatory process, avoiding further corneal surgery. In this article we describe the steam cautery technique and discuss its indications for microbial keratitis.
Does increased electrocautery during adenoidectomy lead to neck pain?
Henry, Lakeisha R; Gal, Thomas J; Mair, Eric A
2005-10-01
The objective was to assess the impact of electrocautery on complications in adenoidectomy. We sought to quantify cautery-related temperature changes in prevertebral fascia that may occur during the procedure, retrospectively evaluate the incidence of cautery-related complications, and prospectively assess the role of cautery in postoperative neck pain. Three consecutive related trials were performed. Initially, adenoidectomy was performed on 20 fresh cadavers, using a thermister to evaluate temperature changes in the prevertebral fascia after electrocautery (30 watts over a 30-second period). Next, retrospective analysis of adenoidectomy complications in 1206 children over a 5-year period was performed. Based on these findings, a prospective study of the incidence of neck pain following adenoidectomy was performed in a cohort of 276 children. Adenoidectomy technique, wattage, and duration of electrocautery were recorded for each child. Children with significant neck pain were evaluated with MRI. Peak thermister readings averaged 74 degrees C, for a mean change of 51.8 degrees C. Complications observed in retrospective analysis included neck pain (3), Grisel's syndrome (1), prolonged velopharyngeal insufficiency (1), retropharyngeal edema (1), and severe nasopharyngeal stenosis (1). The incidence of neck pain in the prospective study was 12% (33 pts), and was independent of adenoidectomy technique, cautery wattage, or duration of cautery use. MRIs revealed edema without abscess. Cautery can result in substantial temperature changes in the surgical adenoid bed. Despite this, the incidence of complications, specifically neck pain, associated with adenoidectomy is low, although underreported. Complications appear to be independent of adenoidectomy technique and cautery use.
[Comparison of 2 lacrimal punctal occlusion methods].
Shalaby, O; Rivas, L; Rivas, A I; Oroza, M A; Murube, J
2001-09-01
To study and compare two methods for canalicular occlusion: Cautery and Punctal Patch. The study included fourty patients divided in two groups of 20 patients. The end point was 4 occluded puncti. The first group underwent deep cauterization resulting in occlusion of the full vertical aspect of the canaliculus. The second group underwent punctal patch technique for canalicular occlusion. Differential parameters were the following: time of intervention, ease of use, risks and precision. In the post operatory, discomfort, subjective and objective improvement in ocular surface as well as long term result of each technique was analysed. Time of intervention was longer for punctal patch compared to cautery. Both methods exhibited similar ease of use and improvement in ocular surface. Precision was high in punctal patch technique showing complete and final occlusion and no punctum needed reopening, while cautery technique presented 20% rate of reopening intervention. Postoperatory discomfort and irritation were remarkably evident with punctal technique, while minimal in cautery technique. Survival analysis after one year follow up, showed a higher rate of advantages for punctal patch technique over cautery technique.
Patil, A A; Yamanashi, W
1994-10-01
A new cautery system known as the electroconvergent cautery system is described. This cautery system uses a radiofrequency current of 13.56 MHz. The current is passed through an amplifier, an impedance matching system, and a loading and tuning coil into a probe. After the probe tip is touched to the tissue, the mismatch of impedance between the probe tip and the generator is minimized to almost zero, resulting in high-current density at the probe tip, which causes pinpoint heating of the tissue at the point where it is touched by the probe without spread of heat to the surrounding tissue. This heat can cut and vaporize tissue and coagulate vessels. The probe can also be used to coagulate vessels with standard surgical forceps. Because convergence of energy is used for tissue heating, a grounding pad is not needed. The system can also be used under cerebrospinal fluid or saline.
Electrolysis-needle cauterization of corneal vessels in patients with lipid keratopathy.
Wertheim, Michael S; Cook, Stuart D; Knox-Cartwright, Nathaniel E; Van, Dung Le; Tole, Derek M
2007-02-01
To describe a technique of corneal vessel occlusion by using electrolysis-needle cautery. A prospective case series of three patients. Corneal vessels were successfully occluded in all patients. Vessels remained occluded during the first 8 months post-cautery follow up. Two patients needed repeat cautery at 9 and 10 months respectively. Patients found the procedure comfortable. There was no post-operative induced astigmatism. The technique of ENC is simple, effective and controlled. This technique compares favorably and may prove to be more versatile than Fine Needle Diathermy in the occlusion of corneal vessels that lead to lipid keratopathy.
Comparison of neural histomorphology in tail tips from pigs docked using clippers or cautery iron.
Kells, N J; Beausoleil, N J; Johnson, C B; Sutherland, M A; Morrison, R S; Roe, W
2017-07-01
Tail docking of pigs is commonly performed to reduce the incidence of unwanted tail-biting behaviour. Two docking methods are commonly used: blunt trauma cutting (i.e. using side clippers), or cutting and concurrent cauterisation using a hot cautery iron. A potential consequence of tail amputation is the development of neuromas at the docking site. Neuromas have been linked to neuropathic pain, which can influence the longer-term welfare of affected individuals. To determine whether method of tail docking influences the extent of neuroma formation, 75 pigs were allocated to one of three treatments at birth: tail docked using clippers; tail docked using cautery iron; tail left intact. Tail docking was performed at 2 days of age and pigs were kept under conventional conditions until slaughter at 21 weeks of age. Tails were removed following slaughter and subjected to histological examination. Nerve histomorphology was scored according to the following scale: 1=discrete well-organised nerve bundles; 2=moderate neural proliferation and disorganisation affecting more than half of the circumference of the tail; 3=marked neural proliferation to form almost continuous disorganised bundles or non-continuous enlarged bundles compressing the surrounding connective tissue. Scores of 2 or 3 indicated neuroma formation. Scores were higher in docked pigs than undocked pigs (P<0.001), but did not differ between pigs docked using clippers and those docked using cautery (P=0.23). The results indicate that tail docking using either clippers or cautery results in neuroma formation, thus having the potential to affect long-term pig welfare.
Safety of Monopolar Electrocautery in Patients With Cochlear Implants.
Tien, Duc A; Woodson, Erika A; Anne, Samantha
2016-09-01
The outcomes of 2 patients with cochlear implants (CIs) who underwent adenotonsillectomy (AT) with inadvertent use of monopolar cautery are presented. The safety data regarding monopolar cautery use in CI recipients is also reviewed. This is a retrospective case series of 2 CI recipients that underwent AT with monopolar cautery and literature review of electrocautery safety in the setting of CI. Two patients with CIs underwent AT with use of monopolar cautery inadvertently by surgeons that do not routinely perform cochlear implants as part of his or her clinical practice. Patient 1 was a 9-year-old female who had AT for obstructive sleep apnea (OSA) after undergoing unilateral CI for profound congenital sensorineural hearing loss (SNHL) 8 years ago. Patient 2 was a 7-year-old female who underwent AT for OSA 4 months after undergoing unilateral CI for congenital SNHL. Both patients had no immediate signs of complications with their CI use postoperatively. Both patients demonstrated unchanged postoperative neural response telemetry and behavioral audiometric testing. Patient 1 continues to have no CI-related complications 3.5 years after the procedure. Patient 2 has been followed for at least 3 months by audiometric testing and 10 months by otolaryngologist with no CI-related complications. Although animal and cadaveric studies suggest that monopolar cautery may be safely used in patients with cochlear implants, there have been no in vivo human studies that have evaluated the risk to the patient or implant. This is a report of a small, unintended experience with 2 patients, both of whom exhibit no complications or changes to CI function thus far. © The Author(s) 2016.
Stock, M L; Barth, L A; Van Engen, N K; Millman, S T; Gehring, R; Wang, C; Voris, E A; Wulf, L W; Labeur, Léa; Hsu, W H; Coetzee, J F
2016-02-01
The objective of this study was to investigate the effects of carprofen administered immediately before cautery dehorning on nociception and stress. Forty Holstein calves aged approximately 6 to 8 wk old were either placebo treated and sham dehorned ( = 10) or cautery dehorned following administration of carprofen (1.4 mg/kg) subcutaneously ( = 10) or orally ( = 10) or a subcutaneous and oral placebo ( = 10) in a randomized, controlled trial. All animals were given a cornual nerve block using lidocaine before dehorning. Response variables including mechanical nociception threshold, ocular temperature, heart rate, and respiratory rate were measured before and following cautery dehorning for 96 h. Blood samples were also collected over 96 h following dehorning and analyzed for plasma cortisol and substance P concentrations by RIA. Plasma carprofen concentration and ex vivo PGE concentrations were also determined for this time period. Average daily gain was calculated for 7 d after dehorning. Data were analyzed using a linear mixed effects model with repeated measures, controlling for baseline values by their inclusion as a covariate in addition to planned contrasts. Dehorning was associated with decreased nociception thresholds throughout the study and a stress response immediately after dehorning, following the loss of local anesthesia, and 48 h after dehorning compared with sham-dehorned calves. Carprofen was well absorbed after administration and reached concentrations that inhibited ex vivo PGE concentrations for 72 h (subcutaneous) and 96 h (oral) compared with placebo-treated calves ( < 0.05). Carprofen-treated calves tended to be less sensitive ( = 0.097) to nociceptive threshold tests. Overall, at the dosing regimen studied, the effect of carprofen on sensitivity and stress following cautery dehorning was minimal. Consideration of route of administration and dose determination studies may be warranted.
Ozdek, Ali; Keseroglu, Kemal
2014-08-01
To define a technique for the practical use of a 16-gauge peripheral venous catheter as an insulated aspiration cautery in endoscopic ear surgery. Retrospective case review. Tertiary referral center. A 16-gauge intravenous catheter was prepared as a cauterization instrument with aspiration. After simple rearrangement of the exterior plastic portion, it was connected to a suction system. With the help of an unipolar cautery, aspiration of the blood and homeostasis was achieved. Hemorrhage of the external ear canal skin after incision can be easily coagulated with this instrument. During follow-up, there were no wound infection, facial nerve paresis, scar formation, and inadvertent burn of the external canal and auricular skin. With the help of this instrument, bleeding control during incision can be easily maintained. It is a simple, easily prepared, and alternative homeostasis technique in endoscopic ear surgery.
Hempstead, Melissa N; Waas, Joseph R; Stewart, Mairi; Cave, Vanessa M; Sutherland, Mhairi A
2018-06-01
We evaluated alternatives to cautery disbudding of goat kids using physiological measures of immediate and longer-term pain. Fifty Saanen doe kids were randomly assigned to 1 of 5 treatments (n = 10/treatment): (1) cautery disbudding (CAUT), (2) caustic paste disbudding (CASP), (3) liquid nitrogen disbudding (CRYO), (4) clove oil injected into the horn bud (CLOV), or (5) sham disbudding (SHAM). Serum cortisol and haptoglobin concentrations were measured from blood samples collected immediately before treatment (baseline) and at 15, 30, 60, and 120 min and then again at 6 and 24 h post-treatment. An infrared thermography camera was used to take images of the horn buds 24 h pre- and 24, 48, and 72 h post-treatment to measure skin temperature. Body weight was measured daily for 1 wk to assess weight change post-treatment. Images of the horn buds were taken at d 1, 2, and 7 and at 6 wk post-treatment to assess tissue damage and wound healing. Mean cortisol concentrations were elevated in CASP kids 1 h post-treatment relative to CAUT kids. Cortisol concentrations of CRYO kids were higher than those of CAUT kids 30 min post-treatment; concentrations for CLOV kids were similar to CAUT kids post-treatment. Mean haptoglobin concentrations were similar across treatments over time; however, CLOV kids had higher concentrations at 24 h post-treatment than all other treatments. Skin temperatures of CASP and CLOV kids were elevated relative to CAUT kids at all time points post-treatment, and all disbudded kids had skin temperatures above those of SHAM kids at 72 h post-treatment. Treatment did not influence weight gain. The CAUT kids had large, open wounds exposing bone; small scabs were still evident 6 wk post-treatment. The CASP kids had red and open, raw wounds that generated large eschars, apparent for up to 6 wk. The CRYO kids had closed, dry wounds initially, but over time lesions appeared that caused open wounds; small scabs were present 6 wk post-treatment. The CLOV kids had closed, dry wounds with blackened skin; healed skin and minimal scabs were present 6 wk post-treatment. Caustic paste and cryosurgical disbudding appeared to cause more pain compared with cautery disbudding; thus, these methods may not provide good alternatives to cautery disbudding. Clove oil appeared to cause a similar pain response as cautery disbudding and smaller wounds with earlier tissue repair; this method shows promise as an alternative to cautery disbudding. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Percutaneous Resection of Renal Urothelial Carcinoma Using Bipolar Electrocautery
Kwan, Kevin G.; Chew, Ben H.; Luke, Patrick P.W.; Denstedt, John D.
2006-01-01
Percutaneous approaches to upper tract urothelial cancers have been performed in patients unsuitable for radical nephroureterectomy. We present the case of an 82-year-old man with significant comorbidities including dependency on a cardiac pacemaker. Without deactivating the pacemaker, we used bipolar cautery to percutaneously resect a large upper tract urothelial tumor in the renal pelvis. Bipolar cautery is a suitable method of percutaneous or transurethral resection in patients who are pacemaker dependent. PMID:17575777
Complications of retrograde balloon cautery endopyelotomy.
Schwartz, B F; Stoller, M L
1999-11-01
Adult ureteropelvic junction obstruction is increasingly managed with endoscopic techniques. Retrograde balloon cautery endopyelotomy is quick, requires minimal hospital stay and allows most patients a rapid return to work. The complication rate of retrograde balloon cautery endopyelotomy ranges from 13 to 34%, with vascular injury in 0 to 16% of patients. We report 5 uncommon complications, including 4 vascular injuries, that clinicians should be familiar with when using this technique. We reviewed 52 retrograde endoscopic endopyelotomy procedures performed during a 5-year period. There were 5 uncommon complications. Accessory lower pole renal artery injuries occurred in 3 patients, 1 of whom presented 12 days after endopyelotomy. Embolization was successfully performed in all 3 cases and none had subsequent hypertension. In 1 case a right ovarian vein laceration was not evident on preoperative or postoperative angiography. Emergency post-embolization abdominal exploration revealed a 2 mm. injury to the right ovarian vein before entering the right renal vein close to the ureteropelvic junction incision. Nephrectomy and ovarian vein ligature were curative. In 1 case the electrocautery wire broke intracorporeally after firing, resulting in a bobby pin-like configuration. Successful removal was accomplished by twisting the catheter and wrapping the wire around the tip, enabling atraumatic removal. Retrograde balloon cautery endopyelotomy is an emerging technology with potential adverse outcomes. The complications we noted are complex and potentially life threatening. Awareness of these complications may help avoid poor outcomes and expedite appropriate treatment.
Bydlon, Torre M.; Barry, William T.; Kennedy, Stephanie A.; Brown, J. Quincy; Gallagher, Jennifer E.; Wilke, Lee G.; Geradts, Joseph; Ramanujam, Nimmi
2012-01-01
Breast conserving surgery (BCS) is a recommended treatment for breast cancer patients where the goal is to remove the tumor and a surrounding rim of normal tissue. Unfortunately, a high percentage of patients return for additional surgeries to remove all of the cancer. Post-operative pathology is the gold standard for evaluating BCS margins but is limited due to the amount of tissue that can be sampled. Frozen section analysis and touch-preparation cytology have been proposed to address the surgical needs but also have sampling limitations. These issues represent an unmet clinical need for guidance in resecting malignant tissue intra-operatively and for pathological sampling. We have developed a quantitative spectral imaging device to examine margins intra-operatively. The context in which this technology is applied (intra-operative or post-operative setting) is influenced by time after excision and surgical factors including cautery and the presence of patent blue dye (specifically Lymphazurin™, used for sentinel lymph node mapping). Optical endpoints of hemoglobin ([THb]), fat ([β-carotene]), and fibroglandular content via light scattering (<µs’>) measurements were quantified from diffuse reflectance spectra of lumpectomy and mastectomy specimens using a Monte Carlo model. A linear longitudinal mixed-effects model was used to fit the optical endpoints for the cautery and kinetics studies. Monte Carlo simulations and tissue mimicking phantoms were used for the patent blue dye experiments. [THb], [β-carotene], and <µs’> were affected by <3.3% error with <80 µM of patent blue dye. The percent change in [β-carotene], <µs’>, and [β-carotene]/<µs’> was <14% in 30 minutes, while percent change in [THb] was >40%. [β-carotene] and [β-carotene]/<µs’> were the only parameters not affected by cautery. This work demonstrates the importance of understanding the post-excision kinetics of ex-vivo tissue and the presence of cautery and patent blue dye for breast tumor margin assessment, to accurately interpret data and exploit underling sources of contrast. PMID:23251526
Huebner, K L; Kunkel, A K; McConnel, C S; Callan, R J; Dinsmore, R P; Caixeta, L S
2017-05-01
Pain management during and following disbudding procedures has been studied extensively, though few studies have evaluated wound healing following cautery disbudding in dairy calves. The purpose of this study was to observe wound healing following cautery disbudding with or without treatment using a topical aluminum-based aerosol bandage (ALU) in preweaned dairy calves. Dairy calves were disbudded within the first 3 wk of life using a standard cautery disbudding protocol. The ALU treatment was randomly allocated to the right or left horn bud within each animal. The outcomes measured were lesion score (LS) and wound diameter (WD). The LS was evaluated on a scale of 1 to 3, with LS = 1 representing normal healing without a scab or exudate, LS = 2 having the presence of a scab, and LS = 3 showing the presence of wound exudate. Lesion score and WD were evaluated on a weekly basis following dehorning for 3 wk. A total of 209 animals completed the study. No difference was observed in LS between groups during the first 2 wk postdisbudding, but the proportion of LS = 3 on wk 3 postdisbudding was greater for the control group when compared with ALU (17 vs. 8%, respectively). During wk 1 and 2 postdisbudding, the odds of having delayed healing, or a LS ≥2, were similar for both groups. However, the odds tended to be different at wk 3 postdisbudding with control disbudding sites being 1.42 times more likely to have delayed healing than ALU. In wk 3, WD was 1 mm smaller in the treatment group compared with the control, and treatment decreased diameter over time compared with controls. Overall, once abnormal wound healing was observed, the likelihood of having abnormal wound healing the following week was increased. However, treatment with ALU diminished this effect on delayed healing during the follow-up period. Based on these results, the use of ALU improved wound healing following cautery disbudding of preweaned dairy calves. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Infrared evaluation of the heat-sink bipolar diathermy dissection technique.
Allan, J; Dusseldorp, J; Rabey, N G; Malata, C M; Goltsman, D; Phoon, A F
2015-08-01
The use of the bipolar diathermy dissection technique is widespread amongst surgeons performing flap perforator dissection and microvascular surgery. The 'heat-sink' modification uses a DeBakey forcep as a heat sinking interposition between the bipolar tip and the main (vascular or flap) pedicle aiming to protect it from the thermal effects of the bipolar diathermy. This study examines the thermal effects of bipolar cautery upon the microvasculature and investigates the efficacy of heat sinking as a thermally protective technique in microsurgical dissection. A chicken thigh microsurgical training model was used to examine the effects of bipolar cautery. The effects of bipolar were examined using high definition, real-time infrared thermographic imaging (FLIR Systems) and temperature quantitatively assessed at various distances away from the point of bipolar cautery. Comparison was made using the heat sink technique to determine if it conferred a thermoprotective effect compared to the standard technique without heat sink. Using paired t-test analysis (SPSS) the heat sink modification of the bipolar dissection technique was found to have a highly statistically significant effect (P < 0.000000001) in reducing the conductive temperature along the vascular pedicle. This protective effect kept temperatures comparable to controls. Bipolar cautery is an extremely safe method of electrosurgery, however when its use is required within 3 mm of important vascular architecture, the heat-sink method is a viable and easy technique to prevent thermal spread and limit potential coagulopathic changes. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Application of a flexible CO(2) laser fiber for neurosurgery: laser-tissue interactions.
Ryan, Robert W; Wolf, Tamir; Spetzler, Robert F; Coons, Stephen W; Fink, Yoel; Preul, Mark C
2010-02-01
The CO(2) laser has an excellent profile for use in neurosurgery. Its high absorption in water results in low thermal spread, sparing adjacent tissue. Use of this laser has been limited to line-of-sight applications because no solid fiber optic cables could transmit its wavelength. Flexible photonic bandgap fiber technology enables delivery of CO(2) laser energy through a flexible fiber easily manipulated in a handheld device. The authors examined and compared the first use of this CO(2) laser fiber to conventional methods for incising neural tissue. Carbon dioxide laser energy was delivered in pulsed or continuous wave settings for different power settings, exposure times, and distances to cortical tissue of 6 anesthetized swine. Effects of CO(2) energy on the tissue were compared with bipolar cautery using a standard pial incision technique, and with scalpel incisions without cautery. Tissue was processed for histological analysis (using H & E, silver staining, and glial fibrillary acidic protein immunohistochemistry) and scanning electron microscopy, and lesion measurements were made. Light microscopy and scanning electron microscopy revealed laser incisions of consistent shape, with central craters surrounded by limited zones of desiccated and edematous tissue. Increased laser power resulted in deeper but not significantly wider incisions. Bipolar cautery lesions showed desiccated and edematous zones but did not incise the pia, and width increased more than depth with higher power. Incisions made without using cautery produced hemorrhage but minimal adjacent tissue damage. The photonic bandgap fiber CO(2) laser produced reliable cortical incisions, adjustable over a range of settings, with minimal adjacent thermal tissue damage. Ease of application under the microscope suggests this laser system has reached true practicality for neurosurgery.
Shah, Anil N; Brewster, Douglas; Mitzen, Kelly; Mullin, David
2015-09-01
Compare intramural bipolar electrocautery and radiofrequency coblation in the treatment of inferior turbinate hypertrophy with regards to objective and subjective improvement in nasal obstruction, rate and type of complications, experience during the procedure, and rate of recovery. Prospective, single-blinded study. Single tertiary medical center from 2008 to 2010. Forty-one adult patients with inferior turbinate hypertrophy refractory to medical management were treated with radiofrequency coblation in one nostril and intramural bipolar cautery in the other. Subjective and objective data, including use of a Visual Analog Scale (VAS) for subjective outcomes, acoustic rhinometry, and nasal endoscopy, were then obtained from each patient comparing the 2 techniques. Radiofrequency coblation was significantly less painful than intramural bipolar cautery during the procedure (P = .03) and during the early postoperative period (P < .02) and produced less crusting at 3 weeks (P = .009). Both interventions were similar in subjective and objective improvements in nasal obstruction as measured by acoustic rhinometry and subjective VAS outcomes. Radiofrequency coblation seems to offer an equivalent alternative to bipolar electrocautery for the treatment of inferior turbinate hypertrophy with less discomfort during the procedure and early post-operative period. © The Author(s) 2015.
Carbon dioxide laser fiber for the excision of oral leukoplakia.
Chee, Michael; Sasaki, Clarence
2013-09-01
We compared the efficacies of cold knife excision and carbon dioxide (CO2) laser fiber excision of oral cavity leukoplakia. Between August 2009 and June 2011,45 patients who underwent excision of oral cavity leukoplakia were assessed for operative time, use of bipolar cautery, blood loss, and number of intraoperative margins needed. Patients were assigned randomly to either a cold knife group (23 procedures) or a CO2 laser fiber group (24 procedures) at the time of the procedure. The times of excision were similar in the CO2 laser fiber group (1.64 min/cm2) and the cold knife group (1.70 min/cm2). There were large differences between the CO2 laser fiber group and the cold knife group in the categories of bipolar cautery uses per square centimeter (0.34 uses versus 3.32 uses) and blood loss (0.19 g/cm2 versus 2.55 g/cm2). The average number of margins needed to clear a specimen by frozen section was 1.21 for the CO2 laser fiber group and 1.83 for the cold knife group. The CO2 laser fiber did not show an advantage in operative time. The CO2 laser fiber did show better outcomes in the areas of blood loss, bipolar cautery use, and intraoperative margins needed.
Craniosynostosis incision: scalpel or cautery?
Wood, Jeyhan S; Kittinger, Benjamin J; Perry, Victor L; Adenola, Adeyemi; van Aalst, John A
2014-07-01
There is an ongoing debate regarding the optimal instrument for scalp incisions: the scalpel or electrocautery. The argument generally focuses on improved healing after an incision made with a knife and decreased bleeding when using electrocautery. This study compares the use of scalpel and electrocautery in making coronal incisions for patients undergoing surgical correction of craniosynostosis. The outcome metric used is wound healing within 6 months after surgery. All patients presenting to the University of North Carolina Children's Hospital with craniosynostosis between July 1, 2007 and January 1, 2010 requiring a coronal incision for surgical correction were prospectively enrolled. In all of these patients, half of the coronal incision was made with knife; the other half, with needle tip cautery. Side of the incision was specified at the time of surgery in the operative report. Patients were excluded from the study if the instrument for incision was not specified or if only 1 modality was used for the entire incision. Sixty-eight patients underwent cranial vault reconstruction, of which 58 met inclusion criteria. Of the 58 matched pairs, 55 were analyzed statistically. The 3 excluded cases were those who had midline complications. There were 17 wound complications (15%): 8 in the knife group, 6 in the cautery group, and 3 at midline (with indeterminate side for the problem). We found no statistically significant difference in wound healing between incisions made with a knife or with electrocautery.
Contact Nd:YAG tonsillectomy: effects on weight loss and recovery.
Maloney, R W
1991-01-01
Contact Nd:YAG tonsillectomy using synthetic sapphire blades appears to meet or exceed standards established by spot monopolar cautery. Subjects' percentage of weight loss and return to work/social activities was measured and the laser group displayed less percentage of weight loss, faster return to pre-operative weight, and less recovery time than the comparative cautery group. Because of the unique nature of Nd:YAG laser light combined with sapphire blades, special consideration should be given to these accessories by physicians before attempting tissue cutting and vessel coagulation. The author believes that the extent of physician training and proficiency may be key to the success of soft tissue head and neck applications, such as tonsillectomy, which will have an effect on the outcome of clinical data.
Effects of electrocautery on transvenous lead insulation materials.
Lim, Kiam-Khiang; Reddy, Shantanu; Desai, Shrojal; Smelley, Matthew; Kim, Susan S; Beshai, John F; Lin, Albert C; Burke, Martin C; Knight, Bradley P
2009-04-01
Insulation defects are a leading cause of transvenous lead failure. The purpose of this study was to determine the effects of electrocautery on transvenous lead insulation materials. A preparation was done to simulate dissection of a transvenous lead from tissues. Radiofrequency energy was delivered using a standard cautery blade at outputs of 10, 20, and 30 W, for 3 and 6 seconds, using parallel and perpendicular blade orientations on leads with outermost insulations of silicone rubber, polyurethane, and silicone-polyurethane copolymer. Damage to each lead segment was classified after visual and microscopic analysis. Significant insulation damage occurred to almost all polyurethane leads. Full insulation breaches were observed with 30 W regardless of application duration with a parallel direction and with all power outputs with a perpendicular direction. Thermal insulation damage to copolymer insulation was similar to that of the polyurethane leads. In contrast, there was no thermal damage to silicone leads, regardless of the power output and duration of power delivery. However, mechanical insulation damage was observed to all silicone leads when at least 20 W was applied in a direction perpendicular to the lead. Polyurethane (PU55D) and copolymer materials have low thermal stability and are highly susceptible to thermal damage during cautery. Implanting physicians should be aware of the lead insulation materials being used during implant procedures and their properties. The use of direct contact cautery on transvenous leads should be minimized to avoid damage to the lead, especially on leads with polyurethane or copolymer outer insulations.
Modelling cost-effectiveness of different vasectomy methods in India, Kenya, and Mexico.
Seamans, Yancy; Harner-Jay, Claudia M
2007-07-13
Vasectomy is generally considered a safe and effective method of permanent contraception. The historical effectiveness of vasectomy has been questioned by recent research results indicating that the most commonly used method of vasectomy--simple ligation and excision (L and E)--appears to have a relatively high failure rate, with reported pregnancy rates as high as 4%. Updated methods such as fascial interposition (FI) and thermal cautery can lower the rate of failure but may require additional financial investments and may not be appropriate for low-resource clinics. In order to better compare the cost-effectiveness of these different vasectomy methods, we modelled the costs of different vasectomy methods using cost data collected in India, Kenya, and Mexico and effectiveness data from the latest published research. The costs associated with providing vasectomies were determined in each country through interviews with clinic staff. Costs collected were economic, direct, programme costs of fixed vasectomy services but did not include large capital expenses or general recurrent costs for the health care facility. Estimates of the time required to provide service were gained through interviews and training costs were based on the total costs of vasectomy training programmes in each country. Effectiveness data were obtained from recent published studies and comparative cost-effectiveness was determined using cost per couple years of protection (CYP). In each country, the labour to provide the vasectomy and follow-up services accounts for the greatest portion of the overall cost. Because each country almost exclusively used one vasectomy method at all of the clinics included in the study, we modelled costs based on the additional material, labour, and training costs required in each country. Using a model of a robust vasectomy program, more effective methods such as FI and thermal cautery reduce the cost per CYP of a vasectomy by $0.08-$0.55. Based on the results presented, more effective methods of vasectomy--including FI, thermal cautery, and thermal cautery combined with FI--are more cost-effective than L and E alone. Analysis shows that for a programme in which a minimum of 20 clients undergo vasectomies per month, the cost per CYP is reduced in all three countries by updated vasectomy methods.
Modelling cost-effectiveness of different vasectomy methods in India, Kenya, and Mexico
Seamans, Yancy; Harner-Jay, Claudia M
2007-01-01
Background Vasectomy is generally considered a safe and effective method of permanent contraception. The historical effectiveness of vasectomy has been questioned by recent research results indicating that the most commonly used method of vasectomy – simple ligation and excision (L and E) – appears to have a relatively high failure rate, with reported pregnancy rates as high as 4%. Updated methods such as fascial interposition (FI) and thermal cautery can lower the rate of failure but may require additional financial investments and may not be appropriate for low-resource clinics. In order to better compare the cost-effectiveness of these different vasectomy methods, we modelled the costs of different vasectomy methods using cost data collected in India, Kenya, and Mexico and effectiveness data from the latest published research. Methods The costs associated with providing vasectomies were determined in each country through interviews with clinic staff. Costs collected were economic, direct, programme costs of fixed vasectomy services but did not include large capital expenses or general recurrent costs for the health care facility. Estimates of the time required to provide service were gained through interviews and training costs were based on the total costs of vasectomy training programmes in each country. Effectiveness data were obtained from recent published studies and comparative cost-effectiveness was determined using cost per couple years of protection (CYP). Results In each country, the labour to provide the vasectomy and follow-up services accounts for the greatest portion of the overall cost. Because each country almost exclusively used one vasectomy method at all of the clinics included in the study, we modelled costs based on the additional material, labour, and training costs required in each country. Using a model of a robust vasectomy program, more effective methods such as FI and thermal cautery reduce the cost per CYP of a vasectomy by $0.08 – $0.55. Conclusion Based on the results presented, more effective methods of vasectomy – including FI, thermal cautery, and thermal cautery combined with FI – are more cost-effective than L and E alone. Analysis shows that for a programme in which a minimum of 20 clients undergo vasectomies per month, the cost per CYP is reduced in all three countries by updated vasectomy methods. PMID:17629921
Ghaly, Ramsis F.; Tverdohleb, Tatiana; Candido, Kenneth D.; Knezevic, Nebojsa Nick
2016-01-01
Background: Spinal cord stimulation is currently approved to treat chronic intractable pain of the trunk and limbs. However, such implantable electronic devices are vulnerable to external electrical currents and magnetic fields. Within the hospitals and modern operating rooms (ORs), there is an abundance of electrical devices and other types of equipment that could interfere with such devices. Despite the increasing number of patients with neuromodulation implantable devices, there are no written guidelines available or consensus of cautions for such patients undergoing unrelated surgery. Case Descriptions: A 60-year-old female with a permanent St. Jude's spinal cord stimulator (SCS) presented for open total abdominal hysterectomy. Both the anesthesia and gynecology staffs were aware of the device presence, but were unaware of any precautions regarding intraoperative management. The device was found to be nonmagnetic resonance imaging compatible, and bipolar cautery was used instead of monopolar cautery. A 59-year-old female with a 9-year-old permanent Medtronic SCS, presented for right total hip arthroplasty. The device was switched off prior to entering the OR, bipolar cautery was used, and grounding pads were placed away from her battery site. In each case, the manufacturer's representative was contacted preoperative. Both surgeries proceeded uneventfully. Conclusions: The Food and Drug Administration safety information manual warns about the use of diathermy, concomitant implanted stimulation devices, lithotripsy, external defibrillation, radiation therapy, ultrasonic scanning, and high-output ultrasound, all of which can lead to permanent implant damage if not turned off prior to undertaking procedures. Lack of uniform guidelines makes intraoperative management, as well as remote anesthesia care of patients with previously implanted SCSs unsafe. PMID:26958424
1988-09-01
Perineoplasty Vaginal cyst, cautery Vaginal web, excision Surgical Patients 95 ORTHOPEDIC Arthrodesis of phalanges Arthroscopy Bone biopsy Bunionectomy...Manipulation of shoulder, knee, or hip Mass excision with scar revision Meniscectomy (if done through arthroscopy ) Metatarsal head, excision unilateral
Kaiy (traditional cautery) in Benghazi, Libya: complications versus effectiveness
Farid, Mona Kamal; El-Mansoury, Abdulla
2015-01-01
Introduction The practice of Kaiy (Cautery) as a traditional therapy is not science based though it is widely practiced worldwide. In Libya, in particular, it is commonly used with no any report or publication to emphasis on its positive or negative impact. This work was undertaken to highlight the complications and disadvantages of kaiy in the Libyan societies as it seems to cause more harm than benefit for the patient. Methods We conducted a questionnaire-based survey in the period from the first of March to the end of April (two months) of the year 2013, on fifty patients who were collected from different hospitals in Benghazi city, and who had experienced Kaiy therapy for different diseases. Results We found that kaiy application is more common among non educated patients (30 patients, 60%). Most of patients (45 cases, 90%) followed their relatives’ advice and that 32 cases (63.5%) did not improve and show undesirable manifestations and complications. Conclusion This study has shown that Kaiy therapy is associated with considerable health risks; therefore, we recommend discouraging and restricting its application. PMID:26848345
Kaiy (traditional cautery) in Benghazi, Libya: complications versus effectiveness.
Farid, Mona Kamal; El-Mansoury, Abdulla
2015-01-01
The practice of Kaiy (Cautery) as a traditional therapy is not science based though it is widely practiced worldwide. In Libya, in particular, it is commonly used with no any report or publication to emphasis on its positive or negative impact. This work was undertaken to highlight the complications and disadvantages of kaiy in the Libyan societies as it seems to cause more harm than benefit for the patient. We conducted a questionnaire-based survey in the period from the first of March to the end of April (two months) of the year 2013, on fifty patients who were collected from different hospitals in Benghazi city, and who had experienced Kaiy therapy for different diseases. We found that kaiy application is more common among non educated patients (30 patients, 60%). Most of patients (45 cases, 90%) followed their relatives' advice and that 32 cases (63.5%) did not improve and show undesirable manifestations and complications. This study has shown that Kaiy therapy is associated with considerable health risks; therefore, we recommend discouraging and restricting its application.
Suter, Melissa J; Gora, Michalina J; Lauwers, Gregory Y; Arnason, Thomas; Sauk, Jenny; Gallagher, Kevin A; Kava, Lauren; Tan, Khay M; Soomro, Amna R; Gallagher, Timothy P; Gardecki, Joseph A; Bouma, Brett E; Rosenberg, Mireille; Nishioka, Norman S; Tearney, Guillermo J
2014-06-01
Biopsy surveillance protocols for the assessment of Barrett's esophagus can be subject to sampling errors, resulting in diagnostic uncertainty. Optical coherence tomography is a cross-sectional imaging technique that can be used to conduct volumetric laser endomicroscopy (VLE) of the entire distal esophagus. We have developed a biopsy guidance platform that places endoscopically visible marks at VLE-determined biopsy sites. The objective of this study was to demonstrate in human participants the safety and feasibility of VLE-guided biopsy in vivo. A pilot feasibility study. Massachusetts General Hospital. A total of 22 participants were enrolled from January 2011 to June 2012 with a prior diagnosis of Barrett's esophagus. Twelve participants were used to optimize the laser marking parameters and the system platform. A total of 30 target sites were selected and marked in real-time by using the VLE-guided biopsy platform in the remaining 10 participants. Volumetric laser endomicroscopy. Endoscopic and VLE visibility, and accuracy of VLE diagnosis of the tissue between the laser cautery marks. There were no adverse events of VLE and laser marking. The optimal laser marking parameters were determined to be 2 seconds at 410 mW, with a mark separation of 6 mm. All marks made with these parameters were visible on endoscopy and VLE. The accuracies for diagnosing tissue in between the laser cautery marks by independent blinded readers for endoscopy were 67% (95% confidence interval [CI], 47%-83%), for VLE intent-to-biopsy images 93% (95% CI, 78%-99%), and for corrected VLE post-marking images 100% when compared with histopathology interpretations. This is a single-center feasibility study with a limited number of patients. Our results demonstrate that VLE-guided biopsy of the esophagus is safe and can be used to guide biopsy site selection based on the acquired volumetric optical coherence tomography imaging data. ( NCT01439633.). Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Suter, Melissa J.; Gora, Michalina J.; Lauwers, Gregory Y.; Arnason, Thomas; Sauk, Jenny; Gallagher, Kevin A.; Kava, Lauren; Tan, Khay M.; Soomro, Amna R.; Gallagher, Timothy P.; Gardecki, Joseph A.; Bouma, Brett E.; Rosenberg, Mireille; Nishioka, Norman S.; Tearney, Guillermo J.
2018-01-01
Background Biopsy surveillance protocols for the assessment of Barrett’s esophagus can be subject to sampling errors, resulting in diagnostic uncertainty. Optical coherence tomography is a cross-sectional imaging technique that can be used to conduct volumetric laser endomicroscopy (VLE) of the entire distal esophagus. We have developed a biopsy guidance platform that places endoscopically visible marks at VLE-determined biopsy sites. Objective The objective of this study was to demonstrate in human participants the safety and feasibility of VLE-guided biopsy in vivo. Design A pilot feasibility study. Setting Massachusetts General Hospital. Patients A total of 22 participants were enrolled from January 2011 to June 2012 with a prior diagnosis of Barrett’s esophagus. Twelve participants were used to optimize the laser marking parameters and the system platform. A total of 30 target sites were selected and marked in real-time by using the VLE-guided biopsy platform in the remaining 10 participants. Intervention Volumetric laser endomicroscopy. Main Outcome Measurements Endoscopic and VLE visibility, and accuracy of VLE diagnosis of the tissue between the laser cautery marks. Results There were no adverse events of VLE and laser marking. The optimal laser marking parameters were determined to be 2 seconds at 410 mW, with a mark separation of 6 mm. All marks made with these parameters were visible on endoscopy and VLE. The accuracies for diagnosing tissue in between the laser cautery marks by independent blinded readers for endoscopy were 67% (95% confidence interval [CI], 47%–83%), for VLE intent-to-biopsy images 93% (95% CI, 78%–99%), and for corrected VLE post-marking images 100% when compared with histopathology interpretations. Limitations This is a single-center feasibility study with a limited number of patients. Conclusion Our results demonstrate that VLE-guided biopsy of the esophagus is safe and can be used to guide biopsy site selection based on the acquired volumetric optical coherence tomography imaging data. (Clinical trial registration number: NCT01439633.) PMID:24462171
Hempstead, Melissa N; Waas, Joseph R; Stewart, Mairi; Dowling, Suzanne K; Cave, Vanessa M; Lowe, Gemma L; Sutherland, Mhairi A
2018-04-01
Cautery disbudding of goat kids is painful, but may be alleviated with pain mitigation. We therefore evaluated the effect of administering general anesthesia (isoflurane) or a nonsteroidal anti-inflammatory drug (meloxicam) on goat kid behavior and physiology following cautery disbudding. Trial 1 (n = 12/treatment) evaluated behavioral responses in 72 female Saanen dairy goat kids (mean ± standard error of the mean; 3.9 ± 0.15 d old) and trial 2 (n = 10/treatment) evaluated physiological responses in 60 female Saanen dairy goat kids (4.3 ± 0.14 d old). Goat kids were randomly assigned to 1 of 6 treatment groups that were either (1) sham-handled only (simulated disbudding; SHAM) or disbudded with (2) no pain relief (CAUT), (3) isoflurane gas (ISO), (4) isoflurane and s.c. meloxicam combined (ISO+MEL), (5) meloxicam s.c. (0.5 mg/kg of body weight; I-MEL), or (6) oral meloxicam (0.2 mg/kg of body weight; O-MEL). Head shaking, head scratching, self-grooming, feeding, and body shaking were continuously video recorded for 24 h pre- and post-treatment. Lying behavior was recorded continuously for 24 h pre- and post-treatment using accelerometers. Plasma cortisol, glucose, and lactate concentrations were measured from blood samples collected immediately before treatment (baseline) and at 15, 60, and 120 min post-treatment. Body temperature was measured immediately after blood sampling at all blood sampling time points. Head shaking and body shaking frequencies were 50% higher in CAUT than SHAM kids 5 min post-treatment; ISO+MEL and ISO kids performed 25% less body shakes than CAUT kids. Head scratching durations 1 h post-treatment were higher in CAUT than SHAM kids, whereas O-MEL were similar to SHAM kids from 2 h post-treatment. Self-grooming, feeding, and lying did not differ between groups. Cortisol concentrations were higher in CAUT than SHAM kids (156.4 ± 26.41 and 104.1 ± 26.41 nmol/L, respectively), whereas ISO+MEL and ISO kids (88.3 ± 26.41 and 113.2 ± 26.41 nmol/L, respectively) had lower cortisol concentrations than CAUT kids over the 2-h sampling period. Moreover, O-MEL and I-MEL kids (163.0 ± 26.41 and 130.9 ± 26.41 nmol/L, respectively) had similar cortisol concentrations to CAUT kids. We found no evidence that plasma glucose and lactate concentrations or body temperature were affected by treatment. The administration of isoflurane, with or without meloxicam, appeared to reduce pain associated with cautery disbudding. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
2010-10-01
Miniature In Vivo Robotic System for the Surgical Treatment of Diverticular Disease Source of Support: National Institute of Health (NIH) Total...completion time • Suturing • Gastrotomy • Partial colon resection • Completion of a fully closed procedure - the robot was inserted...repositioned over the sigmoid colon in the left pelvis of the swine and was used, with one grasper hand and one cautery hand, to dissect out the mesentery of
Middleton, W G; Tees, D A; Ostrowski, M
1993-06-01
Surgical instruments capable of sealing blood vessels while incising skin were compared to standard scalpel incisions in rats and the resultant scars examined in the early stages of wound healing for both gross and histological appearances. Those instruments which provide for hemostasis appear to do so with a delay in the early phases of wound healing.
Kazem, Moslemi Mohammad; Mehdi, Abedin Zadeh; Golrasteh, Kholaseh Zadeh; Behzad, Feis Zadeh
2010-06-01
To evaluate the safety of the Plastibell neonatal circumcision technique and the incidence of complications in Iranian neonates. In this study, 7510 term neonates born between 2001 and 2006 in Rafsanjan medical centers, with age range of 3-36h, were randomized into two groups. In group A (3760 cases), an incision was made in the dorsal surface of the prepuce and then 3min frenular manual compression was performed with a sponge. In group B (3750 cases), frenular hemostasis was achieved using ophthalmologic thermal cautery. The two groups were compared in terms of complications of hemorrhage, wound infection, urine retention and delayed wound healing. In group A, bleeding occurred in 15 cases (0.4%), and in group B in two cases (0.05%). The bleeding rate in group A was significantly higher (P=0.002). In group A, urinary retention was seen in 12 cases (0.03%), in comparison to 35 cases (0.9%) in group B. This complication rate was significantly higher in group B (P=0.001). Local or systemic infection was not seen in either group. Although using thermal cautery we have less bleeding, the total complication rate is increased significantly. Copyright (c) 2010 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Treatment for trichiasis through a combination of eyelash trephination and electrocautery.
Han, Jae-Hyung; Doh, Sang-Hee
2012-05-01
This article introduces 3-mm-deep eyelash trephination combined with electrocautery as a way to increase the success rate for treatment for trichiasis. We have modified surgical instruments, ready-made ophthalmic microtrephine and cautery tip for a 3-mm-deep eyelash trephination and electrocautery. After eyelash trephination with microtrephine, electrocautery was added with a bended cautery tip after embedding in the trephination site. The trephined eyelids were photographed biweekly and checked for recurrence until 8 weeks after operation. Eyelash trephination combined with electrocautery was carried out on 20 Korean patients. The number of removed cilia was 109. Of these, the number of successfully removed hair follicles was 89. During 8 weeks, the total recurring rate of eyelash trephination combined with electrocautery was 17%. In the case of hair follicle removal success with electrocautery, the recurring rate was as low as 11%, but in the case of hair follicle removal failure with electrocautery, recurring rate is 45%. We checked the depth of removed eyelash follicles, and the mean depth was 2.03 ± 0.085 mm in this study. No serious complication was found during the period of this study. The eyelash trephination combined with electrocautery for trichiasis is a method with a low recurrence rate and few complications. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.
Compound Motor Action Potential Quantifies Recurrent Laryngeal Nerve Innervation in a Canine Model.
Bhatt, Neel K; Park, Andrea M; Al-Lozi, Muhammad; Paniello, Randal C
2016-07-01
The compound motor action potential (CMAP) is the summated action potential from multiple muscle fibers activated by a single nerve impulse. The utility of laryngeal muscle CMAP for quantifying innervation following recurrent laryngeal nerve (RLN) injury was investigated. In a series of 21 canine hemi-laryngeal preparations, RLNs were exposed and a stimulating electrode placed. Maximum CMAP amplitudes and area under the curve from the thyroarytenoid (TA) muscles were obtained at baseline and at 6 months following injury to the RLN. Injury mechanisms included crush, stretch, cautery, and complete transection with microsuture repair. Prior to injury, baseline CMAP amplitudes and area under the curve were 15.81 mV and 15.49mVms, respectively. Six months following injury, CMAP amplitude and area under curve were 105.1% and 102.1% of baseline for stretch, 98.7% and 112.7% for crush, 93.3% and 114.3% for cautery. The CMAP amplitude and area under the curve in the transection/repair group had a 54.3% and 69.4% recovery, respectively, which were significantly different than baseline (P < .01, P < .05). These values were correlated with vocal fold motion. The CMAP is a measure of vocal fold innervation. The technique could be further developed for clinical and experimental applications. © The Author(s) 2016.
Swager, Anne-Fré; de Groof, Albert J; Meijer, Sybren L; Weusten, Bas L; Curvers, Wouter L; Bergman, Jacques J
2017-09-01
Volumetric laser endomicroscopy (VLE) provides a circumferential scan of the esophageal wall layers and has potential to improve detection of neoplasia in Barrett's esophagus (BE). The novel VLE laser marking system enables direct in vivo marking of suspicious areas as identified on VLE. These laser marked areas can subsequently be targeted for biopsies. The aim was to evaluate the visibility and positional accuracy of laser marks (LMs) in different esophageal tissue types on white light endoscopy (WLE) and VLE. Patients with BE with or without neoplasia underwent imaging with VLE. Protocol refinements were practiced in a learning phase. In the second phase, visibility of LMs was assessed by random marking in squamous, BE, and gastric tissue. In phase 3, positional accuracy of the LMs was tested by identifying and laser marking surrogate targets (endoscopically placed cautery marks). In the final phase, the most suspicious areas for neoplasia were identified in each patient using VLE, targeted by LMs, and biopsy samples subsequently obtained. Sixteen patients with BE were included (14 men; median age, 68 years), 1 of whom was included twice in different study phases. Worst histologic diagnoses were 9 non-dysplastic Barrett's esophagus (NDBE), 3 low-grade dysplasia (LGD), 4 high-grade dysplasia (HGD), and 1 early adenocarcinoma (EAC). In total, 222 LMs were placed, of which 97% was visible on WLE. All LMs were visible on VLE directly after marking, and 86% could be confirmed during post hoc analysis. LM targeting was successful with positional accuracy in 85% of cautery marks. Inaccurate targeting was caused by system errors or difficult cautery mark visualization on VLE. In the final phase (5 patients), 18 areas suspicious on VLE were identified, which were all successfully targeted by LMs (3 EAC, 3 HGD, 1 LGD, and 11 NDBE). Mean VLE procedure time was 22 minutes (±6 minutes standard deviation); mean endoscopy time was 56 minutes (±17 minutes). No adverse events were reported. This first-in-human study of VLE-guided laser marking was found to be feasible and safe in 17 procedures. Most LMs were visible on WLE and VLE. Targeting VLE areas of interest proved to be highly successful. VLE-guided laser marking may improve the detection and delineation of Barrett's neoplasia in the future. Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
[History of the therapeutic uses of the tinder polypore, Fomes fomentarius (L. : Fr].
Roussel, Bertrand; Rapior, Sylvie; Charlot, Colette; Masson, Christian-Louis; Boutié, Paul
2002-01-01
This paper presents the major therapeutic uses of Fomes fomentarius (L. : Fr.) Fr., tinder polypore. The context of this fungus is a wooly and soft material so called amadou (tinder). During the XVIII and XIXth centuries, the fungal material was used as haemostatic dressing and bandage to keep the temperature and compress parts of the body. It was also used as cautery for moxibustion and was reported in several traditional pharmacopoeias (Hungarian, Chinese, Indian).
Paniello, Randal C
2015-03-01
A new treatment for acute unilateral vocal-fold paralysis (UVFP) was proposed in which a drug is injected into the posterior cricoarytenoid muscle (PCA) shortly after nerve injury, before the degree of natural recovery is known, to prevent antagonistic synkinetic reinnervation. This concept was tested in a series of canine experiments using vincristine as the blocking agent. Animal experiments. Laryngeal adductor function was measured at baseline and at 6 months following experimental recurrent laryngeal nerve (RLN) injuries, including complete transection, crush injury, and cautery. In the treatment animals, the PCA was injected with vincristine at the time of RLN injury. Adductor function in the vincristine-treated hemilarynges was significantly improved compared with injury-matched noninjected controls (total n = 43). Transection/repair controls recovered 56.1% of original adductor strength; vincristine-treated hemilarynges recovered to 73.1% (P = 0.002). Cautery injuries also improved with vincristine block (60.7% vs. 88.7%; P = 0.031). Crush injuries recovered well even without vincristine (104.8% vs. 111.2%; P = 0.35). These findings support a new paradigm of early, preemptive blockade of the antagonist muscle (PCA) to improve ultimate net adductor strength, which could potentially improve functional recovery in many UVFP patients and avoid the need for medialization procedures. Possible clinical aspects of this new approach are discussed. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.
Rare case-series of electrocautery burn following off-pump coronary artery bypass grafting
Sabzi, Feridoun; Niazi, Mojtaba; Ahmadi, Alireza
2014-01-01
Abstract: With an increasing number of off-pump coronary artery surgery procedures in high-risk patients with coagulopathy, including renal failure, hepatic failure and anticoagulant drug-using patients, the frequency of related complications such as repeated exploration for bleeding is also increasing. The associated co-morbidity and repeated use of electrocautery in postoperative bleeding leaves patients susceptible to electrocautery ulcers. In this case series, rare cases of cautery burn with unique causative mechanisms are described. PMID:23669602
A2. Vulval intraepithelial neoplasia (VIN).
Hatch, Kenneth D
2006-11-01
VIN 3 is most likely a cancer precursor and is induced by infection with high-risk types of HPV. VIN 3 lesions may be asymptomatic or present with itching and/or burning or the appearance of a vulval lesion (often raised and hyperpig-mented), which may be unifocal or multifocal. All vulval lesions should be biopsied to confirm the diagnosis. Treatment options include laser vaporization, excision or cautery. Long term follow up is essential. © 2006 International Federation of Gynecology and Obstetrics.
Friedman, Diana C W; Lendvay, Thomas S; Hannaford, Blake
2013-05-01
Our goal was to analyze reported instances of the da Vinci robotic surgical system instrument failures using the FDA's MAUDE (Manufacturer and User Facility Device Experience) database. From these data we identified some root causes of failures as well as trends that may assist surgeons and users of the robotic technology. We conducted a survey of the MAUDE database and tallied robotic instrument failures that occurred between January 2009 and December 2010. We categorized failures into five main groups (cautery, shaft, wrist or tool tip, cable, and control housing) based on technical differences in instrument design and function. A total of 565 instrument failures were documented through 528 reports. The majority of failures (285) were of the instrument's wrist or tool tip. Cautery problems comprised 174 failures, 76 were shaft failures, 29 were cable failures, and 7 were control housing failures. Of the reports, 10 had no discernible failure mode and 49 exhibited multiple failures. The data show that a number of robotic instrument failures occurred in a short period of time. In reality, many instrument failures may go unreported, thus a true failure rate cannot be determined from these data. However, education of hospital administrators, operating room staff, surgeons, and patients should be incorporated into discussions regarding the introduction and utilization of robotic technology. We recommend institutions incorporate standard failure reporting policies so that the community of robotic surgery companies and surgeons can improve on existing technologies for optimal patient safety and outcomes.
Fu, Shangxi; Liu, Xiao; Zhou, Li; Zhou, Meisheng; Wang, Liming
2017-08-01
The purpose of this study was to estimate the effects of surgical laparoscopic operation course on laparoscopic operation skills after the simulated training for medical students with relatively objective results via data gained before and after the practice course of laparoscopic simulator of the resident standardized trainees. Experiment 1: 20 resident standardized trainees with no experience in laparoscopic surgery were included in the inexperienced group and finished simulated cholecystectomy according to simulator videos. Simulator data was collected (total operation time, path length, average speed of instrument movement, movement efficiency, number of perforations, the time cautery is applied without appropriate contact with adhesions, number of serious complications). Ten attending doctors were included in the experienced group and conducted the operation of simulated cholecystectomy directly. Data was collected with simulator. Data of two groups was compared. Experiment 2: Participants in inexperienced group were assigned to basic group (receiving 8 items of basic operation training) and special group (receiving 8 items of basic operation training and 4 items of specialized training), and 10 persons for each group. They received training course designed by us respectively. After training level had reached the expected target, simulated cholecystectomy was performed, and data was collected. Experimental data between basic group and special group was compared and then data between special group and experienced group was compared. Results of experiment 1 showed that there is significant difference between data in inexperienced group in which participants operated simulated cholecystectomy only according to instructors' teaching and operation video and data in experienced group. Result of experiment 2 suggested that, total operation time, number of perforations, number of serious complications, number of non-cauterized bleeding and the time cautery is applied without appropriate contact with adhesions in special group were all superior to those in basic group. There was no statistical difference on other data between special group and basic group. Comparing special group with experienced group, data of total operation time and the time cautery is applied without appropriate contact with adhesions in experienced group was superior to that in special group. There was no statistical difference on other data between special group and experienced group. Laparoscopic simulators are effective for surgical skills training. Basic courses could mainly improve operator's hand-eye coordination and perception of sense of the insertion depth for instruments. Specialized training courses could not only improve operator's familiarity with surgeries, but also reduce operation time and risk, and improve safety.
Serious complications within 30 days of screening and surveillance colonoscopy are uncommon
Ko, Cynthia W.; Riffle, Stacy; Michaels, LeAnn; Morris, Cynthia; Holub, Jennifer; Shapiro, Jean A.; Ciol, Marcia A.; Kimmey, Michael B.; Seeff, Laura C.; Lieberman, David
2009-01-01
Background & Aims The risk of serious complications after colonoscopy has important implications for the overall benefits of colorectal cancer screening programs. We evaluated the incidence of serious complications within 30 days after screening or surveillance colonoscopies in diverse clinical settings and to identify potential risk factors for complications. Methods Patients age 40 and over undergoing colonoscopy for screening, surveillance, or evaluation based an abnormal result from another screening test were enrolled through the National Endoscopic Database (CORI). Patients completed a standardized telephone interview approximately 7 and 30 days after their colonoscopy. We estimated the incidence of serious complications within 30 days of colonoscopy and identified risk factors associated with complications using logistic regression analyses. Results 21,375 patients were enrolled. Gastrointestinal bleeding requiring hospitalization occurred in 34 patients (incidence 1.59/1000 exams; 95% confidence interval [CI] 1.10–2.22). Perforations occurred in 4 patients (0.19/1000 exams; 95% CI 0.05–0.48), diverticulitis requiring hospitalization in 5 patients (0.23/1000 exams; 95% CI 0.08–0.54), and post-polypectomy syndrome in 2 patients (0.09/1000 exams; 95%CI 0.02–0.30). The overall incidence of complications directly related to colonoscopy was 2.01 per 1000 exams (95%CI 1.46–2.71). Two of the four perforations occurred without biopsy or polypectomy. The risk of complications increased with pre-procedure warfarin use and performance of polypectomy with cautery. Conclusions Complications after screening or surveillance colonoscopy are uncommon. Risk factors for complications include warfarin use and polypectomy with cautery. PMID:19850154
Greenstein, Eugene; Passman, Rod; Lin, Albert C; Knight, Bradley P
2012-04-01
The application of radiofrequency electrocautery to a standard, open-ended transseptal needle has been used to facilitate transseptal puncture (TSP). The purpose of this study was to determine the incidence of cardiac tissue coring when this technique is used. A model using excised swine hearts submerged in a saline-filled basin was developed to simulate TSP with electrocautery and a standard transseptal needle. Punctures were performed without the use of electrocautery and by delivering radiofrequency energy to the transseptal needle using a standard electrocautery pen at 3 target sites (fossa ovalis, non-fossa ovalis septum, and aorta). The tissue of the submerged heart was gently tented, and the needle was advanced on delivery of radiofrequency. The devices were retracted, and the needle was flushed in a collection basin. None of the TSPs without cautery caused tissue coring. For TSPs using electrocautery, the frequency of coring was at least 21% for any puncture permutation used in the study and averaged 37% at septal sites (P<0.001 compared with punctures without cautery). Tissue coring occurred in 33 of 96 (35%) punctures through the fossa ovalis and in 38 of 96 (40%) punctures through non-fossa ovalis septum. The frequency of tissue coring at aortic sites was 62 of 96 (65%), which was significantly higher than at the septal sites (P<0.001). In an animal preparation, TSP at the level of the fossa ovalis using electrocautery and a standard open-ended Brockenbrough needle resulted in coring of the septal tissue in 35% of cases (33 of 96 punctures).
Complications of thyroid surgery.
Findlay, John M; Mihai, Radu
2011-03-01
The first recorded thyroid operation is credited to Albucacis in Spain in around the year 1000. About 170 years later, Frugardi attempted to induce atrophy of a goitre by transfixing it with shoelaces. From this surgical technique evolved slowly via methods including mass ligatures, chemical cautery, morcellation and injection of turpentine, to the more familiar concepts of modern thyroidectomy (Hegner, 1932; Dionigi et al, 2008). Today, surgeons continue to refine the technique via new equipment such as Harmonic scalpels and nerve monitors, and novel techniques such as minimally-invasive and non-cervical approaches (e.g. via the axilla or the mouth).
Operating room fires in periocular surgery.
Connor, Michael A; Menke, Anne M; Vrcek, Ivan; Shore, John W
2018-06-01
A survey of ophthalmic plastic and reconstructive surgeons as well as seven-year data regarding claims made to the Ophthalmic Mutual Insurance Company (OMIC) is used to discuss operating room fires in periocular surgery. A retrospective review of all closed claim operating room fires submitted to OMIC was performed. A survey soliciting personal experiences with operating room fires was distributed to all American Society of Oculoplastic and Reconstructive Surgeons. Over the last 2 decades, OMIC managed 7 lawsuits resulting from an operating room fire during periocular surgery. The mean settlement per lawsuit was $145,285 (range $10,000-474,994). All six patients suffered burns to the face, and three required admission to a burn unit. One hundred and sixty-eight surgeons participated in the online survey. Approximately 44% of survey respondents have experienced at least one operating room fire. Supplemental oxygen was administered in 88% of these cases. Most surgical fires reported occurred in a hospital-based operating room (59%) under monitored anesthesia care (79%). Monopolar cautery (41%) and thermal, high-temperature cautery (41%) were most commonly reported as the inciting agents. Almost half of the patients involved in a surgical fire experienced a complication from the fire (48%). Sixty-nine percent of hospital operating rooms and 66% of ambulatory surgery centers maintain an operating room fire prevention policy. An intraoperative fire can be costly for both the patient and the surgeon. Ophthalmic surgeons operate in an oxygen rich and therefore flammable environment. Proactive measures can be undertaken to reduce the incidence of surgical fires periocular surgery; however, a fire can occur at any time and the entire operating room team must be constantly vigilant to prevent and manage operating room fires.
Hefermehl, Lukas J; Largo, Remo A; Hermanns, Thomas; Poyet, Cédric; Sulser, Tullio; Eberli, Daniel
2014-08-01
To assess critical heat spread of cautery instruments used in robot-assisted laparoscopic (RAL) surgery. Thermal spread along bovine musculofascial tissues was examined by infrared camera, histology and enzyme assay. Currently used monopolar, bipolar and ultrasonic laparoscopic instruments were investigated at various power settings and application times. The efficacy of using an additional Maryland clamp as a heat sink was evaluated. A temperature of 45 °C was considered the threshold temperature for possible nerve damage. Monopolar instruments exhibited a mean (sem) critical thermal spread of 3.5 (2.3) mm when applied at 60 W for 1 s. After 2 s, the spread was >20 mm. For adjustable bipolar instruments the mean (sem) critical thermal spread was 2.2 (0.6) mm at 60 W and 1 s, and 3.6 (1.3) mm at 2 s. The PK and LigaSure forceps had mean (sem) critical thermal spreads of 3.9 (0.8) and 2.8 (0.6) mm respectively, whereas the ultrasonic instrument reached 2.9 (0.8) mm. Application of an additional Maryland clamp as a heat sink, significantly reduced the thermal spread. Histomorphometric analyses and enzyme assay supported these findings. All coagulation devices used in RAL surgery have distinct thermal spreads depending on power setting and application time. Cautery may be of concern due to lateral temperature spread, causing potential damage to sensitive structures including nerves. Our results provide surgeons with a resource for educated decision-making when using coagulation devices during robotic procedures. © 2013 The Authors. BJU International © 2013 BJU International.
Thoracic surgery in patients with an implanted neurostimulator device.
Meyring, Kristina; Zehnder, Adrian; Schmid, Ralph A; Kocher, Gregor J
2017-10-01
Movement disorders such as Parkinson's disease are increasingly treated with deep brain stimulators. Being implanted in a subcutaneous pocket in the chest region, thoracic surgical procedures can interfere with such devices, as they are sensible to external electromagnetic forces. Monopolar electrocautery can lead to dysfunction of the device or damage of the brain tissue caused by heat. We report a series of 3 patients with deep brain stimulators who underwent thoracic surgery. By turning off the deep brain stimulators before surgery and avoiding the use of monopolar cautery, electromagnetic interactions were avoided in all patients. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Disposable bipolar irrigated sealer (Aquamantys(®)) for liver resection: use with caution.
Patrizi, Andrea; Jezequel, Caroline; Sulpice, Laurent; Meunier, Bernard; Rayar, Michel; Boudjema, Karim
2016-06-01
The disposable bipolar irrigated sealer has been demonstrated to reduce perioperative bleeding, but its role in preventing postoperative cut-surface complications has not been evaluated to date. A prospective observational study was performed between January and September 2013 to evaluate a disposable bipolar irrigated sealed (Aquamantys(®)) on a continuous series of 51 first liver resections without biliary reconstruction. Primary end-point was the occurrence of cut-surface complications during the postoperative period. Secondary endpoints were postoperative complications and the 1-year overall survival rate. The results were compared to a propensity score matched group of 153 liver resections performed with conventional monopolar cautery. A cut-surface complication occurred in 13/51 (25.5 %) resected patients. Bleeding, bile leakage and subphrenic abscess occurred in 7.8, 11.8 and 11.8 % patients, respectively. Compared to the matched group, the resected group had a higher rate of cut-surface complications (25.5 vs. 14.7 %, p < 0.01) and a higher rate of Clavien-Dindo type ≥3 postoperative complications (29.5 vs. 17.2 %, p < 0.01). In the multivariate analysis, preoperative chemotherapy (p = 0.03, 95 % CI 1.09-5.9, OR 2.53), blood transfusion (p = 0.02, 95 % CI 1.78-6.55, OR 2.78) and Aquamantys(®) use (p = 0.02, 95 % CI 1.21-6.7, OR 2.85) were independent of cut-surface complications within the first 90 postoperative days. The overall 1-year survival rates were not different between the two groups (p = 0.078). Aquamantys(®) use is associated with an increased rate of postoperative complications compared to classical monopolar cautery, and we recommend that it should be used with caution in this type of surgery.
Mehrabian, Ferdous; Eessaei, Fatemeh
2012-03-01
This study aimed to compare two methods of treatment of infertility with gonadotropin with laparoscopic ovarian electrocauterization in patients with clomiphene citrate-resistant polycystic ovary syndrome (PCOS). A number of 104 nulipara patients with polycystic ovary syndrome, who were resistant to clomiphene citrate were randomly assigned to two groups. One group received gonadotropin; after the bleeding withdrawal and from the third day of the cycle, the injection of human menopausal gonadotropin (HMG) was started with 10 mg medroxy progesterone. The patients were followed with serial trans-vaginal sonographies. When the diameter of follicles reached to 18 mm, human chorionic gonadotropin (HCG) was prescribed. The other group was treated with laparoscopic ovarian electrocauterization under general anesthesia. If after 3 cycles, the anovulation was established with progesterone measurement, the clomiphene citrate was prescribed. Gonadotropin was administered, if the lack of ovulation persisted. No significant difference was documented between the two groups in terms of the obesity indexes, duration of infertility, age, sonographic and laboratory findings. In the gonadotropin group, 37 cases (71%) of pregnancy occurred. The rate of pregnancy was the same in the other group consisting of 18 cases treated by electrocautery, 9 cases with cautery + clomiphene, and 10 cases with clomiphene + cautery + gonadotropin. In the group treated with gonadotropin, there were 1 triple and 4 twins pregnancies. In the group treated with ovarian electrocautery, one twin pregnancy was observed. In the group treated with gonadotropin, 2 cases of ovarian hyperstimulation syndrome, 1 case of ectopic pregnancy and 6 cases of miscarriage occurred; the corresponding figure in the ovarian electrocautery group consisted of 5 cases of miscarriage. Our findings suggest that ovarian electrocauterization is an appropriate method with good efficacy and low complication rate for infertility treatment of women with clomiphene citrate-resistant polycystic ovary syndrome.
Bramley, Kyle; Pisani, Margaret A.; Murphy, Terrence E.; Araujo, Katy; Homer, Robert; Puchalski, Jonathan
2016-01-01
Background EBUS-guided transbronchial needle aspiration (TBNA) is important in the evaluation of thoracic lymphadenopathy. Reliably providing excellent diagnostic yield for malignancy, its diagnosis of sarcoidosis is inconsistent. Furthermore, when larger “core” biopsy samples of malignant tissue are required, TBNA may not suffice. The primary objective of this study was to determine if the sequential use of TBNA and a novel technique called cautery-assisted transbronchial forceps biopsies (ca-TBFB) was safe. Secondary outcomes included sensitivity and successful acquisition of tissue. Methods Fifty unselected patients undergoing convex probe EBUS were prospectively enrolled. Under EBUS guidance, all lymph nodes ≥ 1 cm were sequentially biopsied using TBNA and ca-TBFB. Safety and sensitivity were assessed at the nodal level for 111 nodes. Results of each technique were also reported on a per-patient basis. Results There were no significant adverse events. In nodes determined to be malignant, TBNA provided higher sensitivity (100%) than ca-TBFB (78%). However, among nodes with granulomatous inflammation, ca-TBFB exhibited higher sensitivity (90%) than TBNA (33%). For analysis based on patients rather than nodes, 6 of the 31 patients with malignancy would have been missed or understaged if the diagnosis was based on samples obtained by ca-TBFB. On the other hand, 3 of 8 patients with sarcoidosis would have been missed if analysis was based only on TBNA samples. In some cases only ca-TBFB acquired sufficient tissue for the core samples needed in clinical trials of malignancy. Conclusions The sequential use of TBNA and ca-TBFB appears to be safe. The larger samples obtained from ca-TBFB increased its sensitivity to detect granulomatous disease and provided specimens for clinical trials of malignancy when needle biopsies were insufficient. For thoracic surgeons and advanced bronchoscopists, we advocate ca-TBFB as an alternative to TBNA in select clinical scenarios. PMID:26912301
Bramley, Kyle; Pisani, Margaret A; Murphy, Terrence E; Araujo, Katy L; Homer, Robert J; Puchalski, Jonathan T
2016-05-01
Endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration (TBNA) is important in the evaluation of thoracic lymphadenopathy. Reliably providing excellent diagnostic yield for malignancy, its diagnosis of sarcoidosis is inconsistent. Furthermore, TBNA may not suffice when larger "core biopsy" samples of malignant tissue are required. The primary objective of this study was to determine if the sequential use of TBNA and a novel technique called cautery-assisted transbronchial forceps biopsy (ca-TBFB) was safe. Secondary outcomes included sensitivity and successful acquisition of tissue. The study prospectively enrolled 50 unselected patients undergoing convex-probe EBUS. All lymph nodes exceeding 1 cm were sequentially biopsied under EBUS guidance using TBNA and ca-TBFB. Safety and sensitivity were assessed at the nodal level for 111 nodes. Results of each technique were also reported for each patient. There were no significant adverse events. In nodes determined to be malignant, TBNA provided higher sensitivity (100%) than ca-TBFB (78%). However, among nodes with granulomatous inflammation, ca-TBFB exhibited higher sensitivity (90%) than TBNA (33%). On the one hand, for analysis based on patients rather than nodes, 6 of the 31 patients with malignancy would have been missed or understaged if the diagnosis were based on samples obtained by ca-TBFB. On the other hand, 3 of 8 patients with sarcoidosis would have been missed if analysis were based only on TBNA samples. In some patients, only ca-TBFB acquired sufficient tissue for the core samples needed in clinical trials of malignancy. The sequential use of TBNA and ca-TBFB appears to be safe. The larger samples obtained from ca-TBFB increased its sensitivity to detect granulomatous disease and provided adequate specimens for clinical trials of malignancy when specimens from needle biopsies were insufficient. For thoracic surgeons and advanced bronchoscopists, we advocate ca-TBFB as an alternative to TBNA in select clinical scenarios. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Postpolypectomy Electrocoagulation Syndrome: A Mimicker of Colonic Perforation
Benson, Brian C.; Myers, Jonathan J.; Laczek, Jeffrey T.
2013-01-01
Postpolypectomy electrocoagulation syndrome is a rare complication of polypectomy with electrocautery and is characterized by a transmural burn of the colon wall. Patients typically present within 12 hours after the procedure with symptoms mimicking colonic perforation. Presented is the case of a 56-year-old man who developed abdominal pain six hours after colonoscopy during which polypectomy was performed using snare cautery. CT imaging of the abdomen revealed circumferential thickening of the wall of the transverse colon without evidence of free air. The patient was treated conservatively as an outpatient and had resolution of his pain over the following four days. Recognition of the diagnosis and understanding of the treatment are important to avoid unnecessary exploratory laparotomy or hospitalization. PMID:23956889
Principles of physics in surgery: the laws of mechanics and vectors physics for surgeons-part 2.
Srivastava, Anurag; Sood, Akshay; Joy, Parijat S; Mandal, Shubhyan; Panwar, Rajesh; Ravichandran, Suresh; Sarangi, Sasmit; Woodcock, John
2010-10-01
In this sequel, to an earlier article, we discuss the laws of Mechanics, Thermodynamics and Vectors as they apply to soft and bony tissues. These include the Laplace's Law as applied to colonic perforation, compression therapy, parturition, variceal rupture, disc herniations etc. The Pascal's Law finds use in hernia repair and the Heimlich maneuver. Trigonometrically derived components of forces, acting after suturing, show ways to reduce cut-through; the thickness and the bite of suture determines the extent of tissue reaction. The heating effect of current explains the optimum gap between the prongs of a bipolar cautery and the use of law of transfer of heat in determining relation between healthy wound healing and ambient temperature.
Abdullah, M A
1993-01-01
The medical services in Saudi Arabia have improved tremendously over the last two decades, and health centres are easily accessible to more than 93% of the population. Nevertheless, folk medicine, including cautery, bone setting, manual tonsillectomy, uvulectomy, use of herbal medicines and use of harmful teething powders, in addition to religious healing, is widely practised. Reasons include influence of grandparents, religious beliefs and failure of modern medicine to find an answer to some chronic disorders. These problems, and measures to counteract them, are discussed. Attention is also drawn to some of the harmful 'imported' practices that are affecting the health of children, including smoking, children driving cars and problems resulting from dependence on housemaids to bring up children. Some nutritional beliefs and taboos are also mentioned.
Lithotomists, cataract-curers, and hernia-carvers: The Surgical School of Preci.
Davidson, Fiona
2016-11-01
From the 13th to the 18th centuries, a small village in Umbria produced a remarkable multifamily dynasty of highly proficient surgeons. Skilled in lithotomy (cutting for the stone), couching cataracts, repair of hernias, and castration, the Surgeons of Preci or the Norcini, were preeminent in Europe, famous, and wealthy. Sophisticated instruments, use of cautery, knowledge of analgesics, and narcotics were passed down from father to son over 400 years: the most dextrous were summoned by crowned heads, including Charles V1 of France and Elizabeth of England. Yet, the history of their activities is almost forgotten, the result of vicious personal rivalries and the impact of professionalization of 18th-century surgery. Today in Italy, the name Norcini means only pork butcher, ironically the original skill from which the dynasty developed. © The Author(s) 2015.
An experimental model of ectropion uveae and iris neovascularization in the cat.
Hjelmeland, L M; Stewart, M W; Li, J; Toth, C A; Burns, M S; Landers, M B
1992-04-01
Neovascularization of the iris (NVI) is one of the most frequently studied intraocular vascular proliferations in animal models. Ectropion uveae has not been a consistent finding in these studies. In this study, a surgical model of ectropion uveae and iris neovascularization was developed that involved lensectomy, vitrectomy, bipolar cautery and transection of all three principal branch veins in the cat eye. Twelve of 14 eyes that received this procedure developed postoperative retinal detachments with a clinical picture of hemorrhagic retinopathy. These eyes progressed to a clinical picture of NVI within 1-7 wk. Eight eyes developed ectropion uveae for as much as 300 degrees. At the light microscopic level, a fibrovascular membrane was apparent on the anterior iris stroma in 9 of 14 eyes and further involved the angle in six eyes.
Gundeti, Manohar S; Reddy, R Govind; Muralidhar, Jangle Vidya
2014-01-01
Warts are generally managed using cryosurgery, keratolytic ointments, curettage and electrodessication. Warts, vis-a-vis Charmakila, in Ayurvedic classical texts are classified into different types depending on the dominance of dosha. Ayurveda prescribes oral medications, topical use of Kshara (alkaline ash of herbs), Agni (thermal cautery) and Shastrakarma (surgery) for removal of Charmakila. Use of topical Kshara in the form of powder, aqueous solution i.e. Ksharodaka and Ksharasutra (thread smeared with Kshara) for warts has been reported. However, these methods necessitate multiple sittings and takea longer duration for removal of the warts. Herewith, we report a case series of different types of warts treated with intralesional infiltration of Apamarga Ksharodaka (AK), i.e. aqueous solution of Apamarga (Achyranthes aspera) Kshara. We observed that all these warts took a minimum of 2-6 days to shed off, leaving minor scars. There were no adverse reactions reported in any of these cases.
Don't get burned: thermal monitoring of vessel sealing using a miniature infrared camera
NASA Astrophysics Data System (ADS)
Lin, Shan; Fichera, Loris; Fulton, Mitchell J.; Webster, Robert J.
2017-03-01
Miniature infrared cameras have recently come to market in a form factor that facilitates packaging in endoscopic or other minimally invasive surgical instruments. If absolute temperature measurements can be made with these cameras, they may be useful for non-contact monitoring of electrocautery-based vessel sealing, or other thermal surgical processes like thermal ablation of tumors. As a first step in evaluating the feasibility of optical medical thermometry with these new cameras, in this paper we explore how well thermal measurements can be made with them. These cameras measure the raw flux of incoming IR radiation, and we perform a calibration procedure to map their readings to absolute temperature values in the range between 40 and 150 °C. Furthermore, we propose and validate a method to estimate the spatial extent of heat spread created by a cautery tool based on the thermal images.
Ambroise Paré (1510-1590) and His Innovative Work on the Treatment of War Injuries.
Markatos, Konstantinos; Tzivra, Anna; Tsoutsos, Spyridon; Tsourouflis, Gerasimos; Karamanou, Marianna; Androutsos, Georgios
2018-04-01
The purpose of this study is to summarize the innovations of Ambroise Paré (1510-1590) on the treatment of war wounds and improving amputation technique through ligature in arteries and veins. Ambroise Paré debunked the widely accepted idea that gun powder was poisonous for wounds. He also minimized the use of cautery of wounds by his dressing methods and the application of ligature during amputations. All these innovative rationales revolutionized the practice of war surgery during the Renaissance and paved the way for the introduction of modern surgery. Nevertheless, although his wound dressing innovations became widely accepted, the same did not happen with ligature and amputation; those techniques could become widely applicable if one could somehow control bleeding until the blood vessels had been tied. This became possible much later in the 18th century when Jean Louis Petit invented the first useful and efficient tourniquet.
Single-port gynecologic surgery with a novel surgical platform.
Knight, Jason; Tunitsky-Britton, Elena; Muffly, Tyler; Michener, Chad M; Escobar, Pedro F
2012-09-01
Laparoendoscopic single-site surgery (LESS) allows better cosmesis and decreased pain when compared with traditional laparoscopy (TL). Instrument crowding and diminished triangulation are limitations. This study evaluates a novel single-port surgical platform (NSP) designed to facilitate the transition from TL to LESS (TransEnterix SPIDER, Durham, NC). NSP and TL were compared using standardized dry lab tasks. Feasibility of NSP in gynecology was assessed using the porcine model. Completion times with NSP were longer for ring transfer (P = .025) and trended longer for disc cutting (P = .074). Disc cutting accuracy was lower with NSP versus TL (P = .008). NSP operative times for hysterectomy, pelvic and para-aortic node dissection were 22.3, 13.3, and 26 minutes, respectively, without complications. Fatigue and lack of integrated bipolar cautery were limitations of NSP. While application of NSP to gynecology appears feasible, lower performance when compared with TL underscores the need for caution when applying NSP to humans.
In vivo demonstration of surgical task assistance using miniature robots.
Hawks, Jeff A; Kunowski, Jacob; Platt, Stephen R
2012-10-01
Laparoscopy is beneficial to patients as measured by less painful recovery and an earlier return to functional health compared to conventional open surgery. However, laparoscopy requires the manipulation of long, slender tools from outside the patient's body. As a result, laparoscopy generally benefits only patients undergoing relatively simple procedures. An innovative approach to laparoscopy uses miniature in vivo robots that fit entirely inside the abdominal cavity. Our previous work demonstrated that a mobile, wireless robot platform can be successfully operated inside the abdominal cavity with different payloads (biopsy, camera, and physiological sensors). We hope that these robots are a step toward reducing the invasiveness of laparoscopy. The current study presents design details and results of laboratory and in vivo demonstrations of several new payload designs (clamping, cautery, and liquid delivery). Laboratory and in vivo cooperation demonstrations between multiple robots are also presented.
Design of a surgical robot with dynamic vision field control for Single Port Endoscopic Surgery.
Kobayashi, Yo; Sekiguchi, Yuta; Tomono, Yu; Watanabe, Hiroki; Toyoda, Kazutaka; Konishi, Kozo; Tomikawa, Morimasa; Ieiri, Satoshi; Tanoue, Kazuo; Hashizume, Makoto; Fujie, Masaktsu G
2010-01-01
Recently, a robotic system was developed to assist Single Port Endoscopic Surgery (SPS). However, the existing system required a manual change of vision field, hindering the surgical task and increasing the degrees of freedom (DOFs) of the manipulator. We proposed a surgical robot for SPS with dynamic vision field control, the endoscope view being manipulated by a master controller. The prototype robot consisted of a positioning and sheath manipulator (6 DOF) for vision field control, and dual tool tissue manipulators (gripping: 5DOF, cautery: 3DOF). Feasibility of the robot was demonstrated in vitro. The "cut and vision field control" (using tool manipulators) is suitable for precise cutting tasks in risky areas while a "cut by vision field control" (using a vision field control manipulator) is effective for rapid macro cutting of tissues. A resection task was accomplished using a combination of both methods.
The effects of different bill-trimming methods on the well-being of Pekin ducks.
Gustafson, L A; Cheng, H-W; Garner, J P; Pajor, E A; Mench, J A
2007-09-01
Pekin ducks are often bill-trimmed to prevent feather pecking and cannibalism, but this practice has been criticized because of the resulting potential for acute and chronic pain. The goal of this experiment was to compare 2 different bill-trimming methods, hot blade trimming with cautery (TRIM) and cautery only (tip-searing; SEAR), on the behavior, bill morphology, and weight gain of Pekin ducks. Ducklings (n = 192, 96 per sex) were trimmed at the hatchery and assigned to 12 floor pens (3.66 x0.91 m) by treatment. Behavior was evaluated by scan sampling, and plumage condition was scored using a 0 to 3 scoring system. Thirty-six ducks were randomly euthanized at 3 and 6 wk of age, and their bills were collected for examination. Following fixation and decalcification, the bills were embedded in paraffin wax and sectioned longitudinally. Alternate sections were stained with hematoxylin and eosin and Masson's trichrome for the connective tissues, and with Bielschowsky's silver impregnation, Bodian's staining, and Holmes' staining for the nerve fibers. Trimmed ducks engaged in fewer bill-related behaviors and rested more than untrimmed ducks (NOTRIM) during the first 2 wk posttrim. Ducks in the SEAR and NOTRIM groups showed similar patterns of weight gain, but those in the TRIM group had a lower rate of gain than ducks in the SEAR group during the first week posttrim and had a lower rate of gain than those in the NOTRIM group for 2 wk posttrim. Feather scores of ducks in the NOTRIM group were significantly worse than those in the TRIM or SEAR group by 18 d, and scores continued to deteriorate at a greater rate than those of trimmed ducks throughout the study. Both trimming methods caused connective tissue proliferation in the bill stumps, but the TRIM method caused thicker scar tissue than the SEAR method. No neuromas were found with either trimming method, but there were more nerve fibers in bill stumps of the SEAR ducks than the TRIM ducks. These results suggest that acute pain is associated with both trimming methods, but that SEAR may be a preferable method, causing less check in weight gain and fewer bill morphological changes while still being effective in minimizing feather pecking damage.
Alborzi, S; Khodaee, R; Parsanejad, M E
2001-09-01
To evaluate endocrine and ovulatory changes in polycystic ovarian disease (PCOD) in relation to patients' ovarian size. Three hundred and seventy-one women with clomiphene citrate-resistant PCOD underwent laparoscopic ovarian cauterization [type I or typical with ovarian volume >8 cm(3) or cross-sectional area >10 cm(2) (n=211), type II with normal size ovary (n=160)]. Serum levels of LH, FSH, DHEAS, PRL, and T before and 10 days after ovarian cautery, spontaneous and induced ovulation and pregnancy rates were compared. Both groups responded to therapy in a similar manner, with a marked decrease in LH, FSH, DHEAS and T levels, with ovulation rates in type I 90.99%, type II 88.75% and pregnancy rates, 73.45% and 71.25%, respectively, with no statistical differences. Hormonal changes, ovulation and pregnancy rates were similar in the two types of PCOD, therefore it can be concluded that ovarian size is not a prognostic factor for response of PCOD patients to laparoscopic ovarian electro-cauterization.
Fox, Richard; Varadharajan, Kiran; Patel, Bhavesh; Beegun, Issa
2014-01-01
A 30-year-old male body builder and androgenic-anabolic steroid and insulin abuser was admitted for day case elective tonsillectomy (bipolar). He returned with primary post-tonsillectomy haemorrhage 18 h after the operation and required bipolar cautery to the multiple small bleeding points in the right and left tonsillar fossa. Thorough coagulation screen was normal. Recurrent primary haemorrhage occurred 3 h post-operatively requiring immediate surgical intervention, removal of the inferior poles, precautionary throat packs, intubation and observation on the intensive treatment unit (ITU). Re-examination in theatre revealed a bleeding left superior pole that was under-run to achieve haemostasis and the patient returned to ITU. Hypertensive episodes were noted in the emergency department and intraoperatively including one recording >200 mm Hg. Haemostasis was eventually achieved once the blood pressure was adequately controlled. A slow wean of steroids was also instigated and the patient was managed on a surgical ward for 2 weeks post-tonsillectomy. PMID:25398921
Fox, Richard; Varadharajan, Kiran; Patel, Bhavesh; Beegun, Issa
2014-11-14
A 30-year-old male body builder and androgenic-anabolic steroid and insulin abuser was admitted for day case elective tonsillectomy (bipolar). He returned with primary post-tonsillectomy haemorrhage 18 h after the operation and required bipolar cautery to the multiple small bleeding points in the right and left tonsillar fossa. Thorough coagulation screen was normal. Recurrent primary haemorrhage occurred 3 h post-operatively requiring immediate surgical intervention, removal of the inferior poles, precautionary throat packs, intubation and observation on the intensive treatment unit (ITU). Re-examination in theatre revealed a bleeding left superior pole that was under-run to achieve haemostasis and the patient returned to ITU. Hypertensive episodes were noted in the emergency department and intraoperatively including one recording >200 mm Hg. Haemostasis was eventually achieved once the blood pressure was adequately controlled. A slow wean of steroids was also instigated and the patient was managed on a surgical ward for 2 weeks post-tonsillectomy. 2014 BMJ Publishing Group Ltd.
Gundeti, Manohar S.; Reddy, R. Govind; Muralidhar, Jangle Vidya
2014-01-01
Warts are generally managed using cryosurgery, keratolytic ointments, curettage and electrodessication. Warts, vis-a-vis Charmakila, in Ayurvedic classical texts are classified into different types depending on the dominance of dosha. Ayurveda prescribes oral medications, topical use of Kshara (alkaline ash of herbs), Agni (thermal cautery) and Shastrakarma (surgery) for removal of Charmakila. Use of topical Kshara in the form of powder, aqueous solution i.e. Ksharodaka and Ksharasutra (thread smeared with Kshara) for warts has been reported. However, these methods necessitate multiple sittings and takea longer duration for removal of the warts. Herewith, we report a case series of different types of warts treated with intralesional infiltration of Apamarga Ksharodaka (AK), i.e. aqueous solution of Apamarga (Achyranthes aspera) Kshara. We observed that all these warts took a minimum of 2-6 days to shed off, leaving minor scars. There were no adverse reactions reported in any of these cases. PMID:25624698
Kaur, Ravneet Ruby; Glick, Jaimie B.; Siegel, Daniel
2013-01-01
As dermatological procedures continue to become increasingly complex, improved methods and tools to achieve appropriate hemostasis become necessary. The methods for achieving adequate hemostasis are variable and depend greatly on the type of procedure performed and the unique characteristics of the individual patient. In Part 1 of this review, we discuss the preoperative, intraoperative, and postoperative management of patients undergoing dermatologic surgery. We address oral medications and supplements that affect hemostasis, hemostatic anesthesia, and intraoperative interventions such as suture ligation and heat-generating cautery devices. In Part 2 of this review, we will discuss topical hemostats. The authors conducted an extensive literature review using the following keywords: “hemostasis,” “dermatology,” “dermatological surgery,” “dermatologic sutures,” “electrosurgery,” “hemostatic anesthesia,” and “laser surgery.” Sources for this article were identified by searching the English literature in the Pubmed database for the time period from 1940 to March 2012. A thorough bibliography search was also conducted and key references were examined. PMID:23741660
Efficacy of pressure topical anaesthesia in punctal occlusion by diathermy
Law, R W K; Li, R T H; Lam, D S C; Lai, J S M
2005-01-01
Aims: To prospectively compare the efficacy and safety of pressure topical anaesthesia in punctal occlusion by using cautery in the treatment of dry eye syndrome (DES) with that of conventional treatment by using needle injection of anaesthetic agents. Methods: In a randomised controlled trial, 18 consecutive adult patients with DES requiring punctal occlusion were recruited over a 10 month period. Consenting patients were randomised into two groups. Group A patients received pressure topical anaesthesia in the right eye followed by injection anaesthesia in the left eye. Group B was vice versa. Punctal occlusion using cautery was performed in each eye after a specified time following the application of anaesthesia. The main outcome measures were the pain experienced during application of anaesthesia and that during punctal occlusion. Results: 36 eyes of 18 patients were randomised to receive injection anaesthesia in one eye and pressure topical anaesthesia in the other. Nine patients (nine females) were in group A and nine patients (seven females, two males) in group B. The mean age of group A patients was 45.3 (SD 13.5) years, and that of group B patients was 55.6 (12.6) years. The two groups were comparable in terms of mean age (p = 0.117) and mean pain score for pressure topical anaesthesia application (p = 0.612), injection anaesthesia application (p = 0.454), diathermy in pressure anaesthetised eyes (p = 0.113), and diathermy in injection anaesthetised eyes (p = 0.289). Paired t test was used to compare the mean pain score for pressure topical anaesthesia application (16.8 (24.8)) with those for injection anaesthesia application (56.7 (30.0)). 18 eyes of 18 patients were compared with the fellow eye of the same 18 patients. The mean pain score for injection anaesthesia was greater than for pressure topical anaesthesia application (p<0.0001) (statistical power = 0.87). No statistically significant difference was found in the mean pain score for diathermy for eyes that received pressure topical anaesthesia (20.5 (27.5)) compared with eyes that received injection anaesthesia (23.1 (26.3)) (p = 0.760) (statistical power = 0.96). All 18 patients preferred pressure topical anaesthesia to injection anaesthesia. Conclusion: Injection anaesthesia for punctal occlusion is more painful than pressure topical anaesthesia application. However, the pain experienced during diathermy application for punctal occlusion is similar between pressure anaesthetised eyes and injection anaesthetised eyes. Pressure topical anaesthesia is a less painful (in terms of anaesthesia application) but equally effective alternative to conventional injection anaesthesia when used for punctal occlusion. PMID:16234451
Efficacy of pressure topical anaesthesia in punctal occlusion by diathermy.
Law, R W K; Li, R T H; Lam, D S C; Lai, J S M
2005-11-01
To prospectively compare the efficacy and safety of pressure topical anaesthesia in punctal occlusion by using cautery in the treatment of dry eye syndrome (DES) with that of conventional treatment by using needle injection of anaesthetic agents. In a randomised controlled trial, 18 consecutive adult patients with DES requiring punctal occlusion were recruited over a 10 month period. Consenting patients were randomised into two groups. Group A patients received pressure topical anaesthesia in the right eye followed by injection anaesthesia in the left eye. Group B was vice versa. Punctal occlusion using cautery was performed in each eye after a specified time following the application of anaesthesia. The main outcome measures were the pain experienced during application of anaesthesia and that during punctal occlusion. 36 eyes of 18 patients were randomised to receive injection anaesthesia in one eye and pressure topical anaesthesia in the other. Nine patients (nine females) were in group A and nine patients (seven females, two males) in group B. The mean age of group A patients was 45.3 (SD 13.5) years, and that of group B patients was 55.6 (12.6) years. The two groups were comparable in terms of mean age (p=0.117) and mean pain score for pressure topical anaesthesia application (p=0.612), injection anaesthesia application (p=0.454), diathermy in pressure anaesthetised eyes (p=0.113), and diathermy in injection anaesthetised eyes (p=0.289). Paired t test was used to compare the mean pain score for pressure topical anaesthesia application (16.8 (24.8)) with those for injection anaesthesia application (56.7 (30.0)). 18 eyes of 18 patients were compared with the fellow eye of the same 18 patients. The mean pain score for injection anaesthesia was greater than for pressure topical anaesthesia application (p<0.0001) (statistical power=0.87). No statistically significant difference was found in the mean pain score for diathermy for eyes that received pressure topical anaesthesia (20.5 (27.5)) compared with eyes that received injection anaesthesia (23.1 (26.3)) (p=0.760) (statistical power=0.96). All 18 patients preferred pressure topical anaesthesia to injection anaesthesia. Injection anaesthesia for punctal occlusion is more painful than pressure topical anaesthesia application. However, the pain experienced during diathermy application for punctal occlusion is similar between pressure anaesthetised eyes and injection anaesthetised eyes. Pressure topical anaesthesia is a less painful (in terms of anaesthesia application) but equally effective alternative to conventional injection anaesthesia when used for punctal occlusion.
Oculosporidial polyp infected secondarily by Enterobius vermicularis.
Anuradha, S; Bharathi, K; Khalique, Abdul
2014-01-01
Oculosporidiosis caused by Rhinosporidium seeberi is a common infectious disease of south India. Here we are reporting a rare case of oculosporidial polyp containing another parasite Enterobius vermicularis as a co infection. This is the first report of its kind in literature. A nine year old school going girl from a rural area presented with a reddish polypoidal lesion from conjunctiva along with complaints of severe itching over it. On examination, the polyp measured 5 mm × 5 mm in size, reddish, granular with a tendency to bleed on touch. Her vision was normal. All the basic investigations were within normal limits. A differential diagnosis of conjunctival papilloma, foreign body granuloma and oculosporidiosis were considered clinically. The polyp was removed completely using electro cautery with healthy margins around the lesion. To our surprise histopathological examination of the swelling revealed the presence of two different parasites in the conjunctival polyp. Sections showed sporangia of Rhinosporidium seeberi, fragments of Enterobius vermicularis and its eggs. She was then treated with anti helminthic drugs. Two months of follow up till now showed no recurrence of the lesion.
Oculosporidial polyp infected secondarily by Enterobius vermicularis
Anuradha, S.; Bharathi, K.; Khalique, Abdul
2014-01-01
Oculosporidiosis caused by Rhinosporidium seeberi is a common infectious disease of south India. Here we are reporting a rare case of oculosporidial polyp containing another parasite Enterobius vermicularis as a co infection. This is the first report of its kind in literature. A nine year old school going girl from a rural area presented with a reddish polypoidal lesion from conjunctiva along with complaints of severe itching over it. On examination, the polyp measured 5 mm × 5 mm in size, reddish, granular with a tendency to bleed on touch. Her vision was normal. All the basic investigations were within normal limits. A differential diagnosis of conjunctival papilloma, foreign body granuloma and oculosporidiosis were considered clinically. The polyp was removed completely using electro cautery with healthy margins around the lesion. To our surprise histopathological examination of the swelling revealed the presence of two different parasites in the conjunctival polyp. Sections showed sporangia of Rhinosporidium seeberi, fragments of Enterobius vermicularis and its eggs. She was then treated with anti helminthic drugs. Two months of follow up till now showed no recurrence of the lesion. PMID:25337525
Karenberg, A; Hort, I
1998-12-01
This second paper on medieval descriptions and doctrines of stroke reviews concepts outlined by famous Muslim physicians of the Middle Ages such as Rhazes, Haly Abbas, Avicenna, and Averroes. Contrary to a popular belief, Islamic neurological texts represent not only a bridge between ancient and western medieval medical knowledge, but also document remarkable advancements. Whereas statements on diagnosis and prognosis lack originality, the endeavors of physician-philosophers and medical authors led to substantial additions and important changes in theory. Such modifications include the integration of ventricular doctrine and particularly the attempt to unify Aristotelian and Galenic tenets which resulted in a complex discussion about the seats and causes of apoplexy. The fairly simple model handed down by Galenists of the Byzantine period was replaced by more detailed classifications, which proposed "cerebral" as well as "vascular" origins of the disease without suggesting a "cerebrovascular" etiology. Islamic therapeutic strategies included dietetic, pharmacological and surgical elements. The use of the cautery in "chronic apoplexy" was a special feature of Arabic surgery.
Spread of thermal energy and heat sinks: implications for nerve-sparing robotic prostatectomy.
Khan, Farhan; Rodriguez, Esequiel; Finley, David S; Skarecky, Douglas W; Ahlering, Thomas E
2007-10-01
During nerve-sparing robot-assisted laparoscopic prostatectomy, nerve injury caused by thermal energy is a concern. Using a porcine model, we studied thermal spread and queried whether vessels such as the prostatic pedicle may act as a heat sink, reducing the spread of thermal energy. Monopolar (MP) and bipolar (BP) cautery was applied laparoscopically on the anterior abdominal wall surface of six pigs with the da Vinci robot. Using fiberoptic thermometry (Luxtron Inc. Santa Clara, CA), temperatures were recorded with and without the interposed inferior epigastric vessels to evaluate the heat sink effect. Interposition of the inferior epigastric vessels definitively demonstrated a heat sink phenomenon: at 7 mm from the MP/BP energy source, temperatures rose 10.7 degrees C to 13.8 degrees C without interposed vessels versus only 1.9 degrees C to 2.5 degrees C when vessels were interposed (P < 0.001). The heat sink phenomenon suggests that the prostatic vascular pedicle should be protective of the neurovascular bundle during transection of the bladder neck during laparoscopic prostatectomy.
Pulmonary resections: cytostructural effects of different-wavelength lasers versus electrocautery.
Scanagatta, Paolo; Pelosi, Giuseppe; Leo, Francesco; Furia, Simone; Duranti, Leonardo; Fabbri, Alessandra; Manfrini, Aldo; Villa, Antonello; Vergani, Barbara; Pastorino, Ugo
2012-01-01
There are few papers on the cytostructural effects of surgical instruments used during pulmonary resections. The aim of the present study was to evaluate the parenchymal damage caused by different surgical instruments: a new generation electrosurgical scalpel and two different-wavelength lasers. Six surgical procedures of pulmonary resection for nodules were performed using a new generation electrosurgical scalpel, a 1318 nm neodymium (Nd:YAG) laser or a 2010 nm thulium laser (two procedures for each instrument). Specimens were analyzed using optical microscopy and scansion electronic microscopy. Severe cytostructural damage was found to be present in an average of 1.25 mm in depth from the cutting surface in the patients treated using electrosurgical cautery. The depth of this zone dropped to less than 1 mm in patients treated by laser, being as small as 0.2 mm using the laser with a 2010 nm-wavelength and 0.6 mm with the 1318 nm-wavelength laser. These preliminary findings support the use of laser to perform conservative pulmonary resections (i.e., metastasectomies), since it is more likely to avoid damage to surrounding structures. Controlled randomized trials are needed to support the clinical usefulness and feasibility of new types of lasers for pulmonary resections.
Chromaticity based smoke removal in endoscopic images
NASA Astrophysics Data System (ADS)
Tchaka, Kevin; Pawar, Vijay M.; Stoyanov, Danail
2017-02-01
In minimally invasive surgery, image quality is a critical pre-requisite to ensure a surgeons ability to perform a procedure. In endoscopic procedures, image quality can deteriorate for a number of reasons such as fogging due to the temperature gradient after intra-corporeal insertion, lack of focus and due to smoke generated when using electro-cautery to dissect tissues without bleeding. In this paper we investigate the use of vision processing techniques to remove surgical smoke and improve the clarity of the image. We model the image formation process by introducing a haze medium to account for the degradation of visibility. For simplicity and computational efficiency we use an adapted dark-channel prior method combined with histogram equalization to remove smoke artifacts to recover the radiance image and enhance the contrast and brightness of the final result. Our initial results on images from robotic assisted procedures are promising and show that the proposed approach may be used to enhance image quality during surgery without additional suction devices. In addition, the processing pipeline may be used as an important part of a robust surgical vision pipeline that can continue working in the presence of smoke.
Hemostatic agents and instruments in laparoscopic renal surgery.
Msezane, Lambda P; Katz, Mark H; Gofrit, Ofer N; Shalhav, Arieh L; Zorn, Kevin C
2008-03-01
Control of bleeding is one of the most technically challenging steps in laparoscopic renal surgery, especially partial nephrectomy. Although there is no consensus on how best to approach hemostasis, the options continue to expand. The original method of sutured renorrhaphy is, perhaps, the most effective; however, great skill is needed to avoid prolonged warm ischemia. Tissue sealants and adhesives serve as a barrier to leakage and as a hemostat. The four classes are fibrin sealants, collagen-based adhesives, hydrogel, and glutaraldehyde-based adhesive. Additionally, oxidized cellulose can be applied to the surface of kidney or used as a bolster. Fibrin sealants are self-activating and work best on a dry field. The gelatin matrix agent consists of human-derived thrombin with a calcium chloride solution and bovine-derived gelatin matrix. The fibrinogen required to form a clot comes from autologous blood. Another product is polyethylene glycol-based hydrogel, which acts as a mechanical sealant. The tissue glue consists of bovine serum albumin and glutaraldehyde, which cross-link to each other, as well as to other tissue proteins. Excessive use or spillage around the renal pelvis and ureter may compromise urinary flow. The methylcellulose products, consisting of oxidized cellulose sheets, usually are positioned within a sutured bolster and act in part by providing direct pressure. A number of energy-based technologies also have been utilized. Monopolar cautery consists of a high-frequency electrical current delivered from a single electrode. Care must be taken to avoid injurious current transfer to surrounding structures. With bipolar cautery, hemostasis occurs only between the electrodes. In the argonbeam coagulator, argon, an inert non-flammable gas that clears from the body rapidly, is coupled with an electrosurgical generator. The gas creates a more even distribution of the energy and better sealing of the tissues. There have been a few reports of serious complications, including gas embolism and tension pneumothorax. The holmium:YAG laser simultaneously dissects and coagulates tissue. However, its use may be limited by smoke and by blood splashing onto the camera lens, and the tissue vaporization and liquid could promote tumor-cell spillage. The potassium-titanyl-phosphate (KTP) and diode lasers have shown promise in animal studies. The saline-coupled radiofrequency tool uses a standard electrosurgical generator to deliver energy through the conductive fluid. The fluid keeps the surface temperature much lower, increases the contact area, and reduces char and eschar formation. One caveat for the use of instruments that coagulate and ablate tissue is that they can damage the collecting system. Furthermore, the char can make it difficult to assess margin status. In practice, a combination of instruments, sealants, or both generally is utilized to obtain hemostasis. These multimodality efforts may be especially useful in the patient with compromised renal function. On the other hand, the cost can rise quickly when multiple agents are employed. Combining suturing and hemostatic technology may be the best strategy.
NASA Astrophysics Data System (ADS)
Shadgan, Babak; Molavi, Behnam; Reid, W. D.; Dumont, Guy; Macnab, Andrew J.
2010-02-01
Background: Medical and diagnostic applications of near infrared spectroscopy (NIRS) are increasing, especially in operating rooms (OR). Since NIRS is an optical technique, radio frequency (RF) interference from other instruments is unlikely to affect the raw optical data, however, NIRS data processing and signal output could be affected. Methods: We investigated the potential for three common OR instruments: an electrical cautery, an orthopaedic drill and an imaging system, to generate electromagnetic interference (EMI) that could potentially influence NIRS signals. The time of onset and duration of every operation of each device was recorded during surgery. To remove the effects of slow changing physiological variables, we first used a lowpass filter and then selected 2 windows with variable lengths around the moment of device onset. For each instant, variances (energy) and means of the signals in the 2 windows were compared. Results: Twenty patients were studied during ankle surgery. Analysis shows no statistically significant difference in the means and variance of the NIRS signals (p < 0.01) during operation of any of the three devices for all surgeries. Conclusion: This method confirms the instruments evaluated caused no significant interference. NIRS can potentially be used without EMI in clinical environments such as the OR.
NASA Astrophysics Data System (ADS)
Richards, Lisa M.; Weber, Erica L.; Parthasarathy, Ashwin B.; Kappeler, Kaelyn L.; Fox, Douglas J.; Dunn, Andrew K.
2012-02-01
Monitoring cerebral blood flow (CBF) during neurosurgery can provide important physiological information for a variety of surgical procedures. Although multiple intraoperative vascular monitoring technologies are currently available, a quantitative method that allows for continuous monitoring is still needed. Laser speckle contrast imaging (LSCI) is an optical imaging method with high spatial and temporal resolution that has been widely used to image CBF in animal models in vivo. In this pilot clinical study, we adapted a Zeiss OPMI Pentero neurosurgical microscope to obtain LSCI images by attaching a camera and a laser diode. This LSCI adapted instrument has been used to acquire full field flow images from 10 patients during tumor resection procedures. The patient's ECG was recorded during acquisition and image registration was performed in post-processing to account for pulsatile motion artifacts. Digital photographs confirmed alignment of vasculature and flow images in four cases, and a relative change in blood flow was observed in two patients after bipolar cautery. The LSCI adapted instrument has the capability to produce real-time, full field CBF image maps with excellent spatial resolution and minimal intervention to the surgical procedure. Results from this study demonstrate the feasibility of using LSCI to monitor blood flow during neurosurgery.
Torsion of the fallopian tube--a late complication of sterilisation.
Sivanesaratnam, V
1986-02-01
Torsion of an intact fallopian tube, unaccompanied by torsion of the ipsilateral ovary, was noted as a complication of bilateral tubal occlusion by the Pomeroy method in a 45-year old Indian woman. The sterilization was performed 5 years previously, at the time of Cesarean section delivery. The patient presented with a history of pain in the right iliac fossa. Laparotomy showed that the distal segment of the right fallopian tube was twisted 3 times on the distal mesosalpinx and appeared tense and gangrenous. The right ovary was normal and a 2 cm gap was noted between the proximal and distal segments of the tube. As a rare complication of the Pomeroy method, the gap in the tube can allow the distal mesosalpinx to act as a pedicle, and with a long mesosalpinx, the fimbriated segment of the tube lies free and may swing and twist to produce torsion. The occurrence of torsion is further promoted by a vascular disturbance leading to venous congestion, edema, and increased weight of the free fimbrial end of the tube. In those patients with a history of sterilization, torsion of the fallopian tube should be considered in the differential diagnosis of acute lower abdominal pain. Torsion of the fallopian tube has also been reported following other methods of tubal occlusion, including cautery and clips.
Lateral skull base approaches in the management of benign parapharyngeal space tumors.
Prasad, Sampath Chandra; Piccirillo, Enrico; Chovanec, Martin; La Melia, Claudio; De Donato, Giuseppe; Sanna, Mario
2015-06-01
To evaluate the role of lateral skull base approaches in the management of benign parapharyngeal space tumors and to propose an algorithm for their surgical approach. Retrospective study of patients with benign parapharyngeal space tumors. The clinical features, radiology and preoperative management of skull base neurovasculature, the surgical approaches and overall results were recorded. 46 patients presented with 48 tumors. 12 were prestyloid and 36 poststyloid. 19 (39.6%) tumors were paragangliomas, 15 (31.25%) were schwannomas and 11 (23%) were pleomorphic adenomas. Preoperative embolization was performed in 19, stenting of the internal carotid artery in 4 and permanent balloon occlusion in 2 patients. 19 tumors were approached by the transcervical, 13 by transcervical-transparotid, 5 by transcervical-transmastoid, 6, 1 and 2 tumors by the infratemporal fossa approach types A, B and D, respectively. Total radical tumor removal was achieved in 46 (96%) of the cases. Lateral skull base approaches have an advantage over other approaches in the management of benign tumors of the parapharyngeal space due to the fact that they provide excellent exposure with less morbidity. The use of microscope combined with bipolar cautery reduces morbidity. Stenting of internal carotid artery gives a chance for complete tumor removal with arterial preservation. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Chertoff, Jason; Khullar, Vikas; Burke, Lucas
2015-01-01
The utilization of esophagogastroduodenoscopy (EGD) and related procedures continues to rise. Due to this increase in utilization is an inevitable rise in serious complications such as hemorrhage and perforation. One understudied and dreaded complication of EGD causing significant morbidity and mortality is duodenal perforation. We present the case of a 63-year-old male who presented to our institution's emergency room with dyspepsia, melanic stools, tachycardia, and hypotension. Initial laboratory evaluation was significant for severe anemia, lactic acidosis, and acute kidney injury, while CT scan of the abdomen pelvis did not suggest retroperitoneal hematoma or bowel perforation. An emergent EGD was performed which showed multiple bleeding duodenal ulcers that were cauterized and injected with epinephrine. Post-procedure the patient developed worsening abdominal pain, distension, diaphoresis, and tachypnea, requiring emergent intubation. A CT scan of the abdomen and pelvis with oral contrast confirmed pneumoperitoneum and duodenal perforation. Due to the patient's hemodynamic instability and multiple comorbidities, he was treated non-operatively with strict bowel rest and intravenous antibiotics. The patient ultimately had a 19-day hospital course complicated by renal failure requiring hemodialysis and an ischemic limb necessitating above knee amputation. This case describes an unsuccessful attempt at nonoperative management of duodenal perforation following EGD. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Laparoscopic female sterilization.
Filshie, G M
1989-09-01
An overview of laparoscopic sterilization techniques from a historical and practical viewpoint includes instrumentation, operative techniques, mechanical occlusive devices, anesthesia, failure rates, morbidity and mortality. Laparoscope was first reported in 1893, but was developed simultaneously in France, Great Britain, Canada and the US in the 1960s. There are smaller laparoscopes for double-puncture procedures, and larger, single-puncture laparoscopes. To use a ring or clip, a much larger operating channel, up to 8 mm is needed. Insufflating gas may be CO2, which does not support combustion, but is more uncomfortable, NO2, which is also an anesthetic, and room air often used in developing countries. Unipolar electrocautery is now rarely used, in fact most third party payers do not allow it. Bipolar cautery, thermal coagulation and laser photocoagulation are safer methods. Falope rings, Hulka-Clemens, Filshie, Bleier, Weck and Tupla clips are described and illustrated. General anesthesia, usually a short acting agent with a muscle relaxant, causes 33% of the mortality of laparoscope, often due to cardiac arrest and arrhythmias, preventable with atropine. Local anesthesia is safer and cheaper and often used in developing countries. Failure rates of the various laparoscopic tubal sterilization methods are reviewed: most result from fistula formation. Mortality and morbidity can be caused by bowel damage, injury or infection, pre- existing pelvic infection, hemorrhage, gas embolism (avoidable by the saline drip test), and other rare events.
NASA Astrophysics Data System (ADS)
Woo, Peak; Wang, Zhi; Perrault, Donald F., Jr.; McMillan, Kathleen; Pankratov, Michail M.
1995-05-01
Vascular ectasias (dilatation) and vascular lesions of the larynx are difficult to treat with exciting modalities. Varix (enlarged vessel) of the vocal folds, vocal fold hemorrhage, vascular polyp, hemangioma, intubation or contact granuloma are common problems which disturb voice. Current applications of CO2 laser and cautery often damage the delicate vocal fold cover. The 585 nm dermatologic pulsed dye laser may be an ideal substitute. Two adult canines were examined under anesthesia via microlaryngoscopy technique. Pulsed dye laser (SPTL-1a, Candela Laser Corp., Wayland, MA) energy was delivered via the micromanipulator with the 3.1-mm spot size in single pulses of 6, 8, and 10 Joules/cm2 and applied to the vessels of the vocal folds, epiglottis, and arytenoid cartilage. Endoscopic examination was carried out immediately after the treatment and at 4 weeks postoperatively. The animals were sacrificed at 3 weeks, larynges excised, and whole organ laryngeal section were prepared for histology. Pulsed dye laser thrombosed vessels of the vocal fold using 6 or 8 Joules/cm2. Vascular break and leakage occurred at 10 Joules/cm2. Follow up examination showed excellent vessel obliteration or thrombosis without scarring or injury to the overlying tissues. Histologic examination shows vascular thrombosis without inflammation and fibrosis in the vocal fold cover. Pulsed dye laser may have promise in treatment of vascular lesions of the larynx and upper airway.
Conditioned taste aversion and motion sickness in cats and squirrel monkeys
NASA Technical Reports Server (NTRS)
Fox, Robert A.; Corcoran, Meryl Lee; Brizzee, Kenneth R.
1991-01-01
The relationship between vomiting and conditioned taste aversion was studied in intact cats and squirrel monkeys and in cats and squirrel monkeys in which the area postrema was ablated by thermal cautery. In cats conditioned 7-12 months after ablation of the area postrema, three successive treatments with xylazine failed to produce either vomiting or conditioned taste aversion to a novel fluid. Intact cats, however, vomited and formed a conditioned aversion. In squirrel monkeys conditioned 6 months after ablation of the area postrema, three treatments with lithium chloride failed to produce conditioned taste aversion. Intact monkeys did condition with these treatments. Neither intact nor ablated monkeys vomited or evidenced other signs of illness when injected with lithium chloride. When the same ablated cats and monkeys were exposed to a form of motion that produced vomiting prior to surgery, conditioned taste aversion can be produced after ablation of the area postrema. The utility of conditioned taste aversion as a measure of subemetic motion sickness is discussed by examining agreement and disagreement between identifications of motion sickness by conditioned taste aversion and vomiting. It is suggested that a convincing demonstration of the utility of conditioned taste aversion as a measure of nausea requires the identification of physiological correlates of nausea, and caution should be exercised when attempting to interpret conditioned taste aversion as a measure of nausea.
Quantum computing: a prime modality in neurosurgery's future.
Lee, Brian; Liu, Charles Y; Apuzzo, Michael L J
2012-11-01
With each significant development in the field of neurosurgery, our dependence on computers, small and large, has continuously increased. From something as mundane as bipolar cautery to sophisticated intraoperative navigation with real-time magnetic resonance imaging-assisted surgical guidance, both technologies, however simple or complex, require computational processing power to function. The next frontier for neurosurgery involves developing a greater understanding of the brain and furthering our capabilities as surgeons to directly affect brain circuitry and function. This has come in the form of implantable devices that can electronically and nondestructively influence the cortex and nuclei with the purpose of restoring neuronal function and improving quality of life. We are now transitioning from devices that are turned on and left alone, such as vagus nerve stimulators and deep brain stimulators, to "smart" devices that can listen and react to the body as the situation may dictate. The development of quantum computers and their potential to be thousands, if not millions, of times faster than current "classical" computers, will significantly affect the neurosciences, especially the field of neurorehabilitation and neuromodulation. Quantum computers may advance our understanding of the neural code and, in turn, better develop and program implantable neural devices. When quantum computers reach the point where we can actually implant such devices in patients, the possibilities of what can be done to interface and restore neural function will be limitless. Copyright © 2012 Elsevier Inc. All rights reserved.
Treatment of basal cell carcinomas by general practitioners in Australia.
Streeton, Catherine L; Gospodarevskaya, Elena; Harris, Anthony
2006-04-01
Basal cell carcinomas (BCCs) are a relatively common form of skin damage in Australians, involving approximately 1 in 200 general practice encounters per year. To determine current treatments and the associated healthcare resource costs of BCC therapy in Australia. A retrospective survey was undertaken relating to the treatment of patients presenting to their doctor with previously untreated BCCs. Data were collected from a sample of general practitioners who were asked to randomly select two BCC patients from their medical records and complete a questionnaire. Information about treatment types, number of doctor visits, treatment complications, and specialist referrals was extracted from the patient records. One hundred and sixty-four patients were recruited into the study (59% male), who were treated for a total of 244 BCCs (average of 1.5 lesions per patient). Twenty-two per cent of patients were referred to a specialist, most being referred to a general surgeon (45%) or plastic surgeon (25%). Excision was the preferred therapy; second choices were cryosurgery or curettage and cautery. Few adverse events were recorded. The typical number of doctor visits varied from 3.2 to 7.4, with a range of total cost per patient of 146.60-496.20 AUS dollars, depending on complexity and the need for referral. With a reported incidence in Australia of approximately 788 per 100,000 persons, BCCs are not inexpensive to treat for such a relatively common condition.
Herskin, Mette S.; Nielsen, Bodil H.
2018-01-01
Across the international dairy industry, the vast majority of dairy herds have dehorned cows. Farmers choose to dehorn calves for different reasons such as easier handling of non-horned cattle and reduced risk of injuries in animals and staff. This review focuses on disbudding by use of hot-iron cautery as is practiced by dairy farmers in calves <3 months of age. We examine welfare effects of the use of NSAIDs in combination with a local anesthetic including indicators relevant for the three major welfare concerns—affective states, basic health, and functioning as well as the possibility to behave naturally. Across indicators of animal welfare, the majority of available evidence suggest that the use of NSAIDs in combination with a local anesthetic is advantageous in terms of animal welfare, and no studies suggest that NSAIDs are a disadvantage to animal welfare. However, irrespective of the welfare concern, use of NSAIDs combined with a local anesthetic does not fully eliminate the welfare challenges from disbudding. Further research is needed in order to fully understand the effects of this medication protocol on calf welfare, including knowledge about the duration of healing and the presence of long-term pain. At present, this lack of knowledge challenges the precise formulation of adequate pain management—in terms of medication protocol, duration, dosage, and type of administration. PMID:29922684
Assessment of vocal fold mobility before and after cardiothoracic surgery in children.
Carpes, Luthiana F; Kozak, Frederick K; Leblanc, Jacques G; Campbell, Andrew I; Human, Derek G; Fandino, Marcela; Ludemann, Jeffrey P; Moxham, J Paul; Fiori, Humberto
2011-06-01
To assess the incidence of vocal fold immobility (VFI) after cardiothoracic surgery in children and to determine the factors potentially associated with this outcome. Flexible laryngoscopy to assess vocal fold mobility was performed before surgery and within 72 hours after extubation in 100 pediatric patients who underwent cardiothoracic procedures. The 2 operating surgeons recorded the surgical technique and their impression of possible injury to the recurrent laryngeal nerve. The presence of laryngeal symptoms, such as stridor, hoarseness, and strength of cry, after extubation was documented. Of 100 children included in this study, 8 had VFI after surgery. Univariate analyses showed that these 8 patients were younger and weighed less than the patients with normal vocal fold movement. Monopolar cautery was used in all patients with VFI. On univariate analysis, factors statistically significantly associated with VFI were circulatory arrest and dissection or ligation of the patent ductus arteriosus, left pulmonary artery, right pulmonary artery, or descending aorta. However, multivariate analyses failed to show these associations. The incidence of VFI after cardiothoracic surgery in our population of children was 8.0% (8 of 100). Of several factors found to be potentially associated with VFI on univariate analysis, none were significant on multivariate analysis. This may be a result of the few patients with VFI. A larger multicenter prospective study would be needed to definitively identify factors associated with the outcome of VFI.
Delayed presentation of a bowel Bovie injury after laparoscopic ventral hernia repair.
Bhullar, Jasneet Singh; Gayagoy, Jennifer; Chaudhary, Sushant; Kolachalam, Ramachandra B
2013-01-01
Bowel injury during laparoscopic surgery is a rare but serious complication. A Bovie injury to the bowel can cause delayed perforation of the viscus, thus increasing the possibility of a preventable morbidity. Patients presenting with perforation peritonitis within 24 hours and up to 2 to 3 weeks after laparoscopic Bovie injury to the bowel have been reported in the literature. A 74-year-old woman underwent a laparoscopic ventral hernia mesh repair. Intraoperatively, a small area of superficial Bovie injury to the small bowel was repaired with Lembert sutures and tissue glue. Postoperatively, the patient recovered well, but she presented with perforation peritonitis 3 months after surgery. An exploratory laparotomy showed a jejunal perforation in the same area that was injured with cautery and repaired during the previous surgery. The patient was only using inhaled steroids for asthma on and off but had a remote history of chemotherapy and radiation for colorectal cancer. Bovie injury to the bowel has a hidden depth, causing a slow transmural tissue necrosis, and it might also impair local healing and eventually lead to perforation. Thus, the patient may present later than the usual period for wound healing and remodeling as previously reported. Given the disastrous consequence, it is imperative to perform a good surgical repair of even a minor Bovie injury to the bowel. This is the first report of a delayed presentation (>1 month) of a Bovie injury of the bowel.
Delayed Presentation of a Bowel Bovie Injury After Laparoscopic Ventral Hernia Repair
Gayagoy, Jennifer; Chaudhary, Sushant; Kolachalam, Ramachandra B.
2013-01-01
Introduction: Bowel injury during laparoscopic surgery is a rare but serious complication. A Bovie injury to the bowel can cause delayed perforation of the viscus, thus increasing the possibility of a preventable morbidity. Patients presenting with perforation peritonitis within 24 hours and up to 2 to 3 weeks after laparoscopic Bovie injury to the bowel have been reported in the literature. Case Description: A 74-year-old woman underwent a laparoscopic ventral hernia mesh repair. Intraoperatively, a small area of superficial Bovie injury to the small bowel was repaired with Lembert sutures and tissue glue. Postoperatively, the patient recovered well, but she presented with perforation peritonitis 3 months after surgery. An exploratory laparotomy showed a jejunal perforation in the same area that was injured with cautery and repaired during the previous surgery. The patient was only using inhaled steroids for asthma on and off but had a remote history of chemotherapy and radiation for colorectal cancer. Conclusion: Bovie injury to the bowel has a hidden depth, causing a slow transmural tissue necrosis, and it might also impair local healing and eventually lead to perforation. Thus, the patient may present later than the usual period for wound healing and remodeling as previously reported. Given the disastrous consequence, it is imperative to perform a good surgical repair of even a minor Bovie injury to the bowel. This is the first report of a delayed presentation (>1 month) of a Bovie injury of the bowel. PMID:24018096
Effect of cochlear nerve electrocautery on the adult cochlear nucleus.
Iseli, Claire E; Merwin, William H; Klatt-Cromwell, Cristine; Hutson, Kendall A; Ewend, Matthew G; Adunka, Oliver F; Fitzpatrick, Douglas C; Buchman, Craig A
2015-04-01
Electrocauterization and subsequent transection of the cochlear nerve induce greater injury to the cochlear nucleus than sharp transection alone. Some studies show that neurofibromatosis Type 2 (NF2) patients fit with auditory brainstem implants (ABIs) fail to achieve speech perception abilities similar to ABI recipients without NF2. Reasons for these differences remain speculative. One hypothesis posits poorer performance to surgically induced trauma to the cochlear nucleus from electrocautery. Sustained electrosurgical depolarization of the cochlear nerve may cause excitotoxic-induced postsynaptic nuclear injury. Equally plausible is that cautery in the vicinity of the cochlear nucleus induces necrosis. The cochlear nerve was transected in anesthetized adult gerbils sharply with or without bipolar electrocautery at varying intensities. Gerbils were perfused at 1, 3, 5, and 7 days postoperatively; their brainstem and cochleas were embedded in paraffin and sectioned at 10 μm. Alternate sections were stained with flourescent markers for neuronal injury or Nissl substance. In additional experiments, anterograde tracers were applied directly to a sectioned eighth nerve to verify that fluorescent-labeled profiles seen were terminating auditory nerve fibers. Cochlear nerve injury was observed from 72 hours postoperatively and was identical across cases regardless of surgical technique. Postsynaptic cochlear nucleus injury was not seen after distal transection of the nerve. By contrast, proximal transection was associated with trauma to the cochlear nucleus. Distal application of bipolar electrocautery seems safe for the cochlear nucleus. Application near the root entry zone must be used cautiously because this may compromise nuclear viability needed to support ABI stimulation.
Fiek, Michael; Dorwarth, Uwe; Durchlaub, Ilka; Janko, Sabine; Von Bary, Christian; Steinbeck, Gerhard; Hoffmann, Ellen
2004-03-01
During surgical and interventional procedures, interference may occur between ICDs and electrical cautery or with the application of RF energy. This may lead to the false induction of ICD therapies or could even result in device malfunction, which represents a potential perioperative hazard for the patient. This study analyzed the intraoperative interactions in 45 consecutive ICD patients in reference to different surgical and interventional procedures. A total of 33 surgical operations (general surgery [n = 14], urologic [n = 5], abdominal [n = 10], gynecological [n = 2], thoracic [n = 1], neurosurgical [n = 1]) and 12 interventional therapies (RF catheter ablation [n = 10], endoscopic papillotomy [n = 2]) were performed. The ICD devices were all located in left pectoral position and consisted of 25 single and 20 dual chamber defibrillators. During the procedure, tachyarrhythmia detection (VF 296 +/- 20 ms, VT 376 +/- 49 ms) of the devices was maintained active (monitoring mode), only ICD therapies were inactivated. The indifferent electrode of the electrical cauter/RF generator was placed in standard positions (right/left mid-femoral position [n = 27/8], thoracic spine area [n = 10]). After the procedure, the ICD memory was checked for detections and for changes in the programming. There was no oversensing, reprogramming, or damage of any defibrillator caused by RF energy. Despite the lack of undesired interactions, ICDs should be inactivated preoperatively to assure maximum patient safety. However, should inactivation not be possible, or the achievement uncertain, electromagnetic interference is highly unlikely.
Ungi, Tamas; Gauvin, Gabrielle; Lasso, Andras; Yeo, Caitlin T; Pezeshki, Padina; Vaughan, Thomas; Carter, Kaci; Rudan, John; Engel, C Jay; Fichtinger, Gabor
2016-03-01
Lumpectomy, breast conserving tumor excision, is the standard surgical treatment in early stage breast cancer. A common problem with lumpectomy is that the tumor may not be completely excised, and additional surgery becomes necessary. We investigated if a surgical navigation system using intraoperative ultrasound improves the outcomes of lumpectomy and if such a system can be implemented in the clinical environment. Position sensors were applied on the tumor localization needle, the ultrasound probe, and the cautery, and 3-D navigation views were generated using real-time tracking information. The system was tested against standard wire-localization procedures on phantom breast models by eight surgical residents. Clinical safety and feasibility was tested in six palpable tumor patients undergoing lumpectomy by two experienced surgical oncologists. Navigation resulted in significantly less tissue excised compared to control procedures (10.3 ± 4.4 versus 18.6 ± 8.7 g, p = 0.01) and lower number of tumor-positive margins (1/8 versus 4/8) in the phantom experiments. Excision-tumor distance was also more consistently outside the tumor margins with navigation in phantoms. The navigation system has been successfully integrated in an operating room, and user experience was rated positively by surgical oncologists. Electromagnetic navigation may improve the outcomes of lumpectomy by making the tumor excision more accurate. Breast cancer is the most common cancer in women, and lumpectomy is its first choice treatment. Therefore, the improvement of lumpectomy outcomes has a significant impact on a large patient population.
Video. Natural Orifice Translumenal Endoscopic Surgery with a miniature in vivo surgical robot.
Lehman, Amy C; Dumpert, Jason; Wood, Nathan A; Visty, Abigail Q; Farritor, Shane M; Varnell, Brandon; Oleynikov, Dmitry
2009-07-01
The application of flexible endoscopy tools for Natural Orifice Translumenal Endoscopic Surgery (NOTES) is constrained due to limitations in dexterity, instrument insertion, navigation, visualization, and retraction. Miniature endolumenal robots can mitigate these constraints by providing a stable platform for visualization and dexterous manipulation. This video demonstrates the feasibility of using an endolumenal miniature robot to improve vision and to apply off-axis forces for task assistance in NOTES procedures. A two-armed miniature in vivo robot has been developed for NOTES. The robot is remotely controlled, has on-board cameras for guidance, and grasper and cautery end effectors for manipulation. Two basic configurations of the robot allow for flexibility during insertion and rigidity for visualization and tissue manipulation. Embedded magnets in the body of the robot and in an exterior surgical console are used for attaching the robot to the interior abdominal wall. This enables the surgeon to arbitrarily position the robot throughout a procedure. The visualization and task assistance capabilities of the miniature robot were demonstrated in a nonsurvivable NOTES procedure in a porcine model. An endoscope was used to create a transgastric incision and advance an overtube into the peritoneal cavity. The robot was then inserted through the overtube and into the peritoneal cavity using an endoscope. The surgeon successfully used the robot to explore the peritoneum and perform small-bowel dissection. This study has demonstrated the feasibility of inserting an endolumenal robot per os. Once deployed, the robot provided visualization and dexterous capabilities from multiple orientations. Further miniaturization and increased dexterity will enhance future capabilities.
Grushka, Jeremy R; Al-Abbad, Saleh; Baird, Robert; Puligandla, Pramod; Kaplan, Feige; Laberge, Jean-Martin
2010-05-01
Fetal tracheal occlusion (TO) has been investigated as a treatment option for lung hypoplasia secondary to congenital diaphragmatic hernia. Tracheal occlusion has been shown to accelerate lung growth, but its effect on bronchial branching is unknown. In this study, we characterize the effects of in vitro TO on bronchial branch development in fetal lung explants derived from the nitrofen rat model of congenital diaphragmatic hernia. Rat dams were gavaged nitrofen on gestational day 9.5, and fetal lungs were harvested for explant culture on gestational day 14 (term, 22 days). Four experimental groups were investigated, with TO performed ex vivo using cautery: control, control + TO, nitrofen, and nitrofen + TO. Explants were incubated for 72 hours. Representative photographs were taken at 0, 24, 48, and 72 hours from the time of culture, and the number of distal branches was counted for each explant. The Student t test was used to compare distal branch measurements. A minimum of 12 fetal lung explants were cultured for each group. By 24 hours, all explants undergoing TO had more branch iterations than explants that did not. Moreover, TO in nitrofen-exposed explants increased bronchial branching to control levels by 24 hours in culture. Our results suggest that TO at day 14 increases branching in normal and nitrofen-exposed lung explants. In addition, TO increases airway branching in nitrofen-exposed explants to control levels suggesting that early TO reverses the lung hypoplasia seen in this model. Copyright (c) 2010 Elsevier Inc. All rights reserved.
Shires, Courtney Brooke; Saputra, Jennifer Marie; King, Lauren; Thompson, Jerome W.; Heck, Detlef H.; Sebelik, Merry Ellen; Boughter, John Dudley
2015-01-01
Objective To compare operative time and hemostasis of fiber-enabled CO2 laser (FECL) energy to that of the electrocautery (EC) technique for oral tongue resection, to compare return to oral intake and preoperative weight after FECL and EC resection, and to compare histologic changes in adjacent tissue after FECL and EC resection. Study Design Prospective animal study. Setting Research laboratory. Subjects and Methods The CO2 laser fiber and the Bovie cautery were each used to resect the anterior tongue in 15 adult rats. Fixative perfusion and killing were performed on postoperative day 0 (n = 10), 3 (n = 10), or 7 (n = 10). Body weight, food intake, and water intake were recorded daily for 3- and 7-day survival rats. After preparation for histologic analysis, the tongue tissue was graded with a mucosal wound-healing scale (MWHS). Results A higher incidence of intraoperative bleeding and shorter operative times were noted in the EC group. No statistically significant difference in postoperative food or water intake between the EC and FECL groups was noted. The FECL group returned to baseline weight by postoperative day 6. MWHS scores were lower in the EC group by postoperative day 3 and lower in the FECL group by postoperative day 7. Conclusions Both EC and FECL are effective for resection of the tongue in rats. EC has the advantage of shorter operative time and lower MWHS scores by postoperative day 3; FECL has the advantages of less intraoperative bleeding, faster return to baseline body weight, and lower MWHS score by postoperative day 7. PMID:22535916
Overview of plasma technology used in medicine
NASA Astrophysics Data System (ADS)
Ryan, Thomas P.; Stalder, Kenneth R.; Woloszko, Jean
2013-02-01
Plasma Medicine is a growing field that is having an impact in several important areas in therapeutic patient care, combining plasma physics, biology, and clinical medicine. Historically, plasmas in medicine were used in electrosurgery for cautery and non-contact hemostasis. Presently, non-thermal plasmas have attained widespread use in medicine due to their effectiveness and compatibility with biological systems. The paper will give a general overview of how low temperature, non-equilibrium, gas plasmas operate, both from physics and biology perspectives. Plasma is commonly described as the fourth state of matter and is typically comprised of charged species, active molecules and atoms, as well as a source of UV and photons. The most active areas of plasma technology applications are in wound treatment; tissue regeneration; inactivation of pathogens, including biofilms; treating skin diseases; and sterilization. There are several means of generating plasmas for use in medical applications, including plasma jets, dielectric barrier discharges, capacitively or inductively coupled discharges, or microplasmas. These systems overcome the former constraints of high vacuum, high power requirements and bulky systems, into systems that use room air and other gases and liquids at low temperature, low power, and hand-held operation at atmospheric pressure. Systems will be discussed using a variety of energy sources: pulsed DC, AC, microwave and radiofrequency, as well as the range of frequency, pulse duration, and gas combinations in an air environment. The ionic clouds and reactive species will be covered in terms of effects on biological systems. Lastly, several commercial products will be overviewed in light of the technology utilized, health care problems being solved, and clinical trial results.
Graphic and haptic simulation for transvaginal cholecystectomy training in NOTES.
Pan, Jun J; Ahn, Woojin; Dargar, Saurabh; Halic, Tansel; Li, Bai C; Sankaranarayanan, Ganesh; Roberts, Kurt; Schwaitzberg, Steven; De, Suvranu
2016-04-01
Natural Orifice Transluminal Endoscopic Surgery (NOTES) provides an emerging surgical technique which usually needs a long learning curve for surgeons. Virtual reality (VR) medical simulators with vision and haptic feedback can usually offer an efficient and cost-effective alternative without risk to the traditional training approaches. Under this motivation, we developed the first virtual reality simulator for transvaginal cholecystectomy in NOTES (VTEST™). This VR-based surgical simulator aims to simulate the hybrid NOTES of cholecystectomy. We use a 6DOF haptic device and a tracking sensor to construct the core hardware component of simulator. For software, an innovative approach based on the inner-spheres is presented to deform the organs in real time. To handle the frequent collision between soft tissue and surgical instruments, an adaptive collision detection method based on GPU is designed and implemented. To give a realistic visual performance of gallbladder fat tissue removal by cautery hook, a multi-layer hexahedral model is presented to simulate the electric dissection of fat tissue. From the experimental results, trainees can operate in real time with high degree of stability and fidelity. A preliminary study was also performed to evaluate the realism and the usefulness of this hybrid NOTES simulator. This prototyped simulation system has been verified by surgeons through a pilot study. Some items of its visual performance and the utility were rated fairly high by the participants during testing. It exhibits the potential to improve the surgical skills of trainee and effectively shorten their learning curve. Copyright © 2016 Elsevier Inc. All rights reserved.
Pros and cons of colonoscopy in management of acute lower gastrointestinal bleeding
Lhewa, Dekey Y; Strate, Lisa L
2012-01-01
Acute lower gastrointestinal bleeding (LGIB) is a frequent gastrointestinal cause of hospitalization, particularly in the elderly, and its incidence appears to be on the rise. Endoscopic and radiographic measures are available for the evaluation and treatment of LGIB including flexible sigmoidoscopy, colonoscopy, angiography, radionuclide scintigraphy and multi-detector row computed tomography. Although no modality has emerged as the gold standard in the management of LGIB, colonoscopy is the current preferred initial test for the majority of the patients presenting with hematochezia felt to be from a colon source. Colonoscopy has the ability to diagnose all sources of bleeding from the colon and, unlike the radiologic modalities, does not require active bleeding at the time of the examination. In addition, therapeutic interventions such as cautery and endoclips can be applied to achieve hemostasis and prevent recurrent bleeding. Studies suggest that colonoscopy, particularly when performed early in the hospitalization, can decrease hospital length of stay, rebleeding and the need for surgery. However, results from available small trials are conflicting and larger, multicenter studies are needed. Compared to other management options, colonoscopy is a safe procedure with complications reported in less than 2% of patients, including those undergoing urgent examinations. The requirement of bowel preparation (typically 4 or more liters of polyethylene glycol), the logistical complexity of coordinating after-hours colonoscopy, and the low prevalence of stigmata of hemorrhage complicate the use of colonoscopy for LGIB, particularly in urgent situations. This review discusses the above advantages and disadvantages of colonoscopy in the management of acute lower gastrointestinal bleeding in further detail. PMID:22468081
Drudi, Laura; Press, Joshua Z; Lau, Susie; Gotlieb, Raphael; How, Jeffrey; Eniu, Ioana; Drummond, Nancy; Brin, Sonya; Deland, Claire; Gotlieb, Walter H
2013-06-01
Vaginal vault dehiscence following robotic-assisted hysterectomy for gynecologic cancer may be attributed to surgical techniques and postoperative therapeutic interventions. We searched for risk factors in patients with gynecologic cancers and complemented this with a literature review. Evaluation of prospectively gathered information on all consecutive robotic surgeries for gynecologic cancers was performed in a tertiary academic cancer center between December 2007 and March 2012. The literature was reviewed for articles relevant to "gynecologic oncology" and "robotics" with "vaginal cuff dehiscence" in the English and French languages. Respective authors were contacted to complete relevant information. Seven dehiscences were identified of 441 cases with established gynecologic cancers. The closures in these 7 were performed using interrupted 1-Vicryl (Ethicon Inc) (3/167; 1.8%), combination of interrupted 1-Vicryl and 1-Biosyn (Covidien Inc) (3/156, 1.9%), and V-Loc (Covidien Inc) (1/118, 0.8%) sutures. Associated risk factors included adjuvant chemotherapy and/or brachytherapy, early resumption of sexual activity, and low body mass index (mean, 23 ± 3.23 kg/m²). Dehiscences occurred regardless of suturing by staff or trainees. Review of operative videos did not reveal a detectable etiologic factor, such as excessive cautery damage to the vaginal cuff or shallow tissue sutured. All 7 colporrhexis repairs were performed through a vaginal approach without the need of laparoscopy or laparotomy. Postoperative chemotherapy, brachytherapy, and early resumption of sexual activities are risk factors for vaginal vault dehiscence. Surgical technique, particularly the use of delayed absorbable sutures, deserves further evaluation.
Endoscopic cubital tunnel release using the Hoffmann technique.
Hoffmann, Reimer; Lubahn, John
2013-06-01
Endoscopic cubital tunnel release was originally described in 1989 by Tsai, and his technique has been modified by other surgeons including Mirza and Cobb. In 2006, Hoffmann and Siemionow described an endoscopic technique quite different from Tsai's original description. Instead of working from the "inside out," Hoffmann's technique is performed through an incision similar to that which would be used for an in situ release of the ulnar nerve. The main difference being that the nerve can be explored and decompressed 10 cm proximal and distal to the arcuate ligament as the surgeon looks down on the nerve and the surrounding tissues while viewing the anatomy through a camera attached to a soft tissue endoscope that is inserted in the wound. The arcuate (Osborne's) ligament is released under direct vision much like a standard in situ decompression. Using a blunt dissection instrument, a workspace is created proximally and distally to the cubital tunnel. Next an illuminated speculum is introduced, the nerve is directly visualized between 4 and 5 cm proximal and distal to the cubital tunnel, and potential compressive forearm fasciae or fibrous bands are released. Finally, a 15-cm, 30° soft tissue endoscope is introduced into the incision, and viewing the internal anatomy on a video monitor, the decompression continues using longer scissors. Any potential bleeding is controlled with a long bayonet bipolar cautery. The authors discuss indications, contraindications, and the surgical technique. Postoperative management and associated complications are also discussed. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Measurement of electromagnetic tracking error in a navigated breast surgery setup
NASA Astrophysics Data System (ADS)
Harish, Vinyas; Baksh, Aidan; Ungi, Tamas; Lasso, Andras; Baum, Zachary; Gauvin, Gabrielle; Engel, Jay; Rudan, John; Fichtinger, Gabor
2016-03-01
PURPOSE: The measurement of tracking error is crucial to ensure the safety and feasibility of electromagnetically tracked, image-guided procedures. Measurement should occur in a clinical environment because electromagnetic field distortion depends on positioning relative to the field generator and metal objects. However, we could not find an accessible and open-source system for calibration, error measurement, and visualization. We developed such a system and tested it in a navigated breast surgery setup. METHODS: A pointer tool was designed for concurrent electromagnetic and optical tracking. Software modules were developed for automatic calibration of the measurement system, real-time error visualization, and analysis. The system was taken to an operating room to test for field distortion in a navigated breast surgery setup. Positional and rotational electromagnetic tracking errors were then calculated using optical tracking as a ground truth. RESULTS: Our system is quick to set up and can be rapidly deployed. The process from calibration to visualization also only takes a few minutes. Field distortion was measured in the presence of various surgical equipment. Positional and rotational error in a clean field was approximately 0.90 mm and 0.31°. The presence of a surgical table, an electrosurgical cautery, and anesthesia machine increased the error by up to a few tenths of a millimeter and tenth of a degree. CONCLUSION: In a navigated breast surgery setup, measurement and visualization of tracking error defines a safe working area in the presence of surgical equipment. Our system is available as an extension for the open-source 3D Slicer platform.
Thoracoscopic bilateral T3 sympathectomy for primary focal hyperhidrosis in children.
Laje, Pablo; Rhodes, Kali; Magee, Leanne; Klarich, Mary Kate
2017-02-01
Present our experience in the surgical treatment of primary focal hyperhidrosis of the hands by thoracoscopic bilateral T3 sympathectomy in pediatric patients. Retrospective chart review of all patients operated between 2013 and 2015. We operated and included in the study 28 patients, 22 females and 6 males. Mean age was 14 (6-21) years. All patients had previously tried at least one form of medical therapy with no success. All patients were extensively counseled regarding the potential side effects of the sympathectomy. The operations were done in supine position with the arms extended. All patients were intubated with a double-lumen endotracheal tube for sequential lung isolation. We used a 5-mm port for the scope and a 3-mm port for the instruments, both placed in the axilla. The third rib was identified by fluoroscopy. The sympathectomy was done with monopolar cautery. Mean operative time was 43 (25-71) minutes. No chest tubes were used. The incidence of intraoperative or postoperative complications was zero. All patients were discharged within the first 24 postoperative hours. All patients achieved immediate complete postoperative resolution of the palmar hyperhidrosis, sustained in all cases at a median follow-up of 17 (2-34) months. The mean preoperative quality of life score (based on a multifunctional self-assessment questionnaire) was 41/100, whereas after the operation, it was 92/100. Only 1 patient developed temporary compensatory sweating. All patients were satisfied with the result of the operation. Thoracoscopic bilateral T3 sympathectomy is a safe and effective treatment for children and adolescents with primary focal hyperhidrosis of the hands who failed medical management and have a very low rate of compensatory sweating. IV. Copyright © 2017 Elsevier Inc. All rights reserved.
Taskin, O; Yalcinoglu, A I; Kafkasli, A; Burak, F; Ozekici, U
1996-06-01
To study the effects of laparoscopic ovarian cauterization and combination of long-acting GnRH agonist (GnRH-a) and oral contraceptive (OC) therapy on endocrine changes in women with clomiphene citrate (CC)- resistant polycystic ovary disease (PCOD). Prospective, randomized. University-based infertility clinic. Seventeen women with CC-resistant PCOD were included randomly in the study to either laparoscopic ovarian cautery or GnRH-a and OC therapy for 3 months. Serum concentrations of LH, FSH, androstenedione (A), T, and sex hormone-binding globulin (SHBG) were determined before each therapeutic approach and during the follicular phase of first menstrual cycle after the cessation of each treatment. The mean serum concentrations and the clinical profiles were similar in both groups. Both groups showed significant changes in LH, FSH, A, T, and SHBG compared with pretreatment levels. There were no significant differences in the final concentrations of LH, FSH, and A between the two study groups after each treatment, whereas T and SHBG levels were significantly different in the goserelin and OC group. The decrease in LH and increase in SHBG serum concentrations were greater in the goserelin and OC-treated women [-59% and + 5.9% versus - 70% and + 13.5%, respectively]. Although the SHBG concentration increased in both groups, the serum SHBG concentration of the goserelin and OC group was significantly higher than the other group. Both therapeutic modalities revealed similar effects on the endocrine profiles in women with CC-resistant PCOD. Considering the invasiveness, cost, and potential complications of laparoscopic ovarian cauterization, noninvasive medical treatment with GnRH-a and OC combination may be more effective in restoring the optimal follicular environment in women with PCOD.
Moore, John B; Hasenboehler, Erik A
2007-11-07
Ischemic orchitis is an established complication after open inguinal hernia repair, but ischemic orchitis resulting in orchiectomy after the laparoscopic approach has not been reported. The patient was a thirty-three year-old man who presented with bilateral direct inguinal hernias, right larger than left. He was a thin, muscular male with a narrow pelvis who underwent bilateral extraperitoneal mesh laparoscopic inguinal hernia repair. The case was complicated by pneumoperitoneum which limited the visibility of the pelvic anatomy; however, the mesh was successfully deployed bilaterally. Cautery was used to resect the direct sac on the right. The patient was discharged the same day and doing well with minimal pain and swelling until the fourth day after surgery. That night he presented with sudden-onset pain and swelling of his right testicle and denied both trauma to the area and any sexual activity. Ultrasound of the testicle revealed no blood flow to the testicle which required exploration and subsequent orchiectomy. Ischemic orchitis typically presents 2-3 days after inguinal hernia surgery and can progress to infarction. This ischemic injury is likely due to thrombosis of the venous plexus, rather than iatrogenic arterial injury or inappropriate closure of the inguinal canal. Ultrasound/duplex scanning of the postoperative acute scrotum can help differentiate ischemic orchitis from infarction. Unfortunately, testicular torsion cannot be ruled out and scrotal exploration may be necessary. Although ischemic orchitis, atrophy, and orhiectomy are uncommon complications, all patients should be warned of these potential complications and operative consent should include these risks irrespective of the type of hernia or the surgical approach.
Management of third branchial pouch anomalies - an evolution of a minimally invasive technique.
Wong, Phui Yee; Moore, Andrew; Daya, Hamid
2014-03-01
The management of third branchial pouch anomalies has evolved in recent times with the popularisation of the endoscopic diathermy technique to sclerose the pyriform fossa sinus opening. We present our experience in managing 3 children with third branchial pouch anomalies and propose a minimally invasive management algorithm avoiding open neck surgery. Retrospective case review of 3 patients including demographics, mode of presentation, investigations, management and complications. Three children, two male and one female of mean age 9.6 years presented with painful left anterior neck swelling. Axial neck imaging showed a superficial abscess with air locules and a sinus tract leading towards the left pharynx. Diagnosis was confirmed by endoscopic examination of the pyriform fossa revealing a sinus opening. Two patients underwent open excision; one combined with diathermy to the sinus opening. The last patient was diagnosed at his initial presentation and managed with endoscopic diathermy of the sinus opening combined with percutaneous needle aspiration of the neck abscess at the same sitting. One patient had two recurrences, the first after initial open surgery and the second after the first cautery. Two patients developed temporary hoarseness after the procedure, which resolved within two weeks. All patients were free from recurrences at follow-up. Introduction of the technique of endoscopic diathermy to the pyriform fossa sinus opening in children with third branchial pouch anomalies has revolutionised their management avoiding open and potentially morbid surgery. Our algorithm takes this further by advocating percutaneous needle aspiration of the infective component and performing diathermy to the sinus opening at the first presentation. Crown Copyright © 2013. Published by Elsevier Ireland Ltd. All rights reserved.
Prospective evaluation of biodegradable polymeric sealant for intraoperative air leaks.
Park, Bernard J; Snider, John M; Bates, Nathan R; Cassivi, Stephen D; Jett, G Kimble; Sonett, Joshua R; Toloza, Eric M
2016-12-12
A biodegradable polymeric sealant has been previously shown to reduce postoperative air leaks after open pulmonary resection. The aim of this study was to evaluate safety and efficacy during minimally invasive pulmonary resection. In a multicenter prospective single-arm trial, 112 patients with a median age of 69 years (range 34-87 years) were treated with sealant for at least one intraoperative air leak after standard methods of repair (sutures, staples or cautery) following minimally invasive pulmonary resection (Video-Assisted Thoracic Surgery (VATS) or Robotic-Assisted). Patients were followed in hospital and 1 month after surgery for procedure-related and device-related complications and presence of air leak. Forty patients had VATS and 72 patients had Robotic-Assisted procedures with the majority (80/112, 71%) undergoing anatomic resection (61 lobectomy, 13 segmentectomy, 6 bilobectomy). There were no device-related adverse events. The overall morbidity rate was 41% (46/112), with major complications occurring in 16.1% (18/112). In-hospital mortality and 30-day mortality were 1.9% (2/103). The majority of intraoperative air leaks (107/133, 81%) were sealed after sealant application, and an additional 16% (21/133) were considered reduced. Forty-nine percent of patients (55/112) were free of air leak throughout the entire postoperative study period. Median chest tube duration was 2 days (range 1 - 46 days), and median length of hospitalization was 3 days (range 1 - 20 days). This study demonstrated that use of a biodegradable polymer for closure of intraoperative air leaks as an adjunct to standard methods is safe and effective following minimally invasive pulmonary resection. ClinicalTrials.gov: NCT01867658 . Registered 3 May 2013.
Yang, Yu-Long; Zhang, Cheng; Zhao, Gang; Wu, Ping; Ma, Yue-Feng; Zhang, Hong-Wei; Shi, Li-Jun; Li, Jing-Yi; Lin, Mei-Ju; Yang, Shi-Ming; Lv, Yi
2015-09-01
Hepatolithiasis is associated with the presence of intrahepatic biliary strictures, and balloon dilatation is the main approach. However, this method is difficult to implement if the bile duct distal to the stricture is blocked by stones. Therefore, alternative methods need to be explored to effectively treat hepatolithiasis. The aim of this study is to investigate the feasibility and effectiveness of choledochoscopic high-frequency needle-knife electrotomy for the treatment of intrahepatic biliary strictures. Clinical data of 58 patients suffering from intrahepatic bile duct strictures from January 2011 to January 2013 were retrospectively analyzed. Choledochoscopic electrotomy was used to resolve the strictures. One hundred thirty-four sites of intrahepatic bile duct strictures were discovered. The average operating time of electrotomy is 5.6 min (range, 1 ∼ 15 min). Structured bile duct tissue bleeding occurred in eight sites (8/134, 6.0%) but were resolved by endoscopic high-frequency electric cautery. After the operations, 14 cases of cholangitis (14/58, 24.1%), three cases of delayed hemobilia, one case of liver abscess (1/58, 1.7%), and seven cases of stenting exodus (7/58, 12.1%) were observed despite conservative treatment and stenting reset. The average supporting time was 7.0 months (6 ∼ 9 months). No abnormal bile duct structure or presence of stone was found according to choledochoscopy. The follow-up period ranged from 12 to 48 months. Hepatolithiasis recurred in five (5/58, 8.6%) patients, and the cumulative recurrent probability of intrahepatic bile duct stricture was 5.2% (7/134). Choledochoscopic high-frequency needle-knife electrotomy could be considered as a simple, safe, and effective complementary approach for treating intrahepatic biliary strictures. © 2015 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.
The Effect of Student Gender on the Obstetrics and Gynecology Clerkship Experience
Odrobina, Michele R.; McIntyre-Seltman, Kathleen
2010-01-01
Abstract Objectives To explore the effects of the students' gender on their perception of quality and quantity of teaching, the amount of experiential learning, and their interest in obstetrics and gynecology. Methods Anonymous, self-administered surveys to third-year medical students rotating on the obstetrics and gynecology clerkship. Results Eighty-one of 91 students participated (89% response rate): 33 men, 46 women, 2 declined to reveal their gender. No significant gender differences existed regarding number of interactions with residents and faculty; number of deliveries, surgeries, or examinations performed; perceived quality of teaching; or feeling included as part of the clinical team. Male students were more likely to report performing specific surgical procedures, such as operating the bovie cautery during gynecological surgeries (p = 0.005). More men experienced patients refusing to allow them to participate in the clinical interview (p < 0.0001) and physical examination (p < 0.0001). Male students were also more likely to report feeling that their gender negatively impacted their clerkship experience (p < 0.0001). Although less likely to report preclerkship and postclerkship career interest in obstetrics and gynecology, male students were more likely to report that their interest increased at the end of the clerkship. Conclusions Male students were more likely to experience gender bias from patients on the obstetrics and gynecology service. Male students also described feeling socially excluded from female-dominated clinical teams. Obstetrics and gynecology educators need to consider methods of encouraging patients to accept medical student participation regardless of gender. Obstetrics and gynecology faculty and residents need to be sensitive to subtle forms of gender bias and ensure equal inclusion for both male and female medical students. PMID:20088663
Dadgarnia, Mohammad Hossein; Aghaei, Mohammad Ali; Atighechi, Saeid; Behniafard, Nasim; Vahidi, Mohammad Reza; Meybodian, Mojtaba; Zand, Vahid; Vajihinejad, Maryam; Ansari, Abdollah
2016-10-01
Although tonsillectomy is one of the most common surgeries performed in pediatric, it has potential major complications such as pain and bleeding. This study aimed to compare the bleeding and pain after tonsillectomy in bipolar electrocautery tonsillectomy versus cold dissection. This double blind clinical trial was conducted on 70 pediatric patients who were candidate of tonsillectomy. Patients were divided into two groups of including bipolar cautery (BC) and cold dissection (CD). operation time, intraoperative blood loss, and postoperative bleeding and pain were evaluated in the current study. In both of the CD and BC groups, no significant difference was found in terms of sex and age. The average amount of the intraoperative blood loss in BC group was 14.086 ± 5.013 ml and in CD group was 26.14 ± 4.46 ml (p. v = 0.0001). The mean time of operation in BC group was 19 ± 2.89 min and in CD group was 29.31 ± 5.29 min (p. v = 0.0001). patients were evaluated in terms of pain on the first, third, fifth, and seventh days after the operation. No statistically significant difference was found between two groups. Moreover, Compared pain scores in all times across two groups, no significant difference was found. In terms of postoperative bleeding, none of the patients in both groups had bleeding during follow-up. Our study showed that bipolar electrocautery tonsillectomy can significantly reduce the operation time and intraoperative blood loss; however, postoperative pain and blood loss were similar in both techniques. We recommend bipolar electrocautery as the most suitable alternative method for tonsillectomy, especially in children. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Ball, Chad G; Campbell, Andre; Grondin, Sean C; Dixon, Elijah; DuBose, Joseph; McBeth, Paul B; Lall, Rohan
2016-09-01
Solid organ (liver, spleen and kidney) haemorrhage is often life threatening and can be difficult to stop in critically ill patients. Traditional techniques for arresting this ongoing bleeding include coagulation by high voltage cautery (Bovie), topical haemostatic application, and the delivery of ignited argon gas. The goal of this study was to evaluate the efficacy of a new energy device for arresting persistent solid organ haemorrhage. A novel instrument utilizing bipolar radiofrequency (RF) energy which acts to ignite/boil dripping saline from a simple hand piece was employed to arrest ongoing bleeding from solid organ injuries at 2 high volume, level 1 trauma centres. This instrument is extrapolated from experience within elective hepatic resections. Standard statistics were employed (p<0.05=significant). From January 2013 to January 2015, 36 severely injured patients (mean injury severity score=31; blunt mechanisms=32/36 (89%)) underwent use of this new saline/RF energy instrument to arrest ongoing haemorrhage from the liver (29), spleen (5) and kidney (2). Of these patients, 25 received instrument use during an initial laparotomy, while 11 patients underwent use following removal of sponges during a return laparotomy after an initial damage control procedure. Success in arresting ongoing haemorrhage was 97% (35/36) in these highly selected cases. The surgeons reported an 'ease of use' score of 4.9 out of 5. No postoperative complications (including delayed haemorrhage) were noted as a direct result of the energy instrument. This simple saline/RF energy instrument has the potential to arrest ongoing solid organ surface/capsular bleeding, as well as moderate haemorrhage associated with deep lacerations. Copyright © 2016 Elsevier Ltd. All rights reserved.
Recurrent laryngeal nerve recovery patterns assessed by serial electromyography.
Paniello, Randal C; Park, Andrea M; Bhatt, Neel K; Al-Lozi, Muhammad
2016-03-01
Following acute injury to the recurrent laryngeal nerve (RLN), laryngeal electromyography (LEMG) is increasingly being used to determine prognosis for recovery. The LEMG findings change during the recovery process, but the timing of these changes is not well described. In this canine study, LEMGs were obtained serially following model RLN injuries. Animal Study. Thirty-six canine RLNs underwent crush (n = 6), complete transection with reanastomosis (n = 6), half-transection half-crush (n = 5), cautery (n = 5), stretch (n = 5), inferior crush (n = 4), or inferior transection with reanastomosis (n = 5) injuries. Injuries were performed 5 cm from cricoid or were 5 cm further inferior. Under light sedation, LEMG of thyroarytenoid muscles was performed monthly for 6 months following injury. At 6 months, spontaneous and induced vocal fold motion was assessed. Except for the stretch injury, the remaining groups showed very similar recovery patterns. Fibrillation potentials (FPs) and/or positive sharp waves (PSWs; signs of bad prognosis) were seen in all cases at 1 month and lasted on average for 2.26 months (range = 1-4 months). Motor unit potentials of at least 2+ (scale = 0-4+; signs of good prognosis) were seen beginning at 3.61 months (range = 2-6 months). The stretch injury was less severe, with 3 of 5 showing no FPs/PSWs at 1 month; all recovered full mobility. Ten of the 36 thyroarytenoid muscles (27.8%) had 1 electromyograph showing both bad prognosis and good prognosis signs simultaneously at 2 to 4 months postinjury. LEMG can be used to predict RNL recovery, but timing is important and LEMG results earlier than 3 months may overestimate a negative prognosis. NA Laryngoscope, 126:651-656, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
Endoscopic and non-endoscopic approaches for the management of radiation-induced rectal bleeding
Weiner, Joseph Paul; Wong, Andrew Thomas; Schwartz, David; Martinez, Manuel; Aytaman, Ayse; Schreiber, David
2016-01-01
Pelvic radiation is a commonly utilized treatment for malignancy of the genitourinary and lower gastrointestinal tract. Radiation proctitis and the resultant clinical picture varies from asymptomatic to potentially life threatening. Similarly, treatment options also vary greatly, from medical therapy to surgical intervention. Commonly utilized medical therapy includes sucralfate enemas, antibiotics, 5-aminosalicylic acid derivatives, probiotics, antioxidants, short-chain fatty acids, formalin instillation and fractionated hyperbaric oxygen. More invasive treatments include endoscopic-based, focally ablative interventions such as dilation, heater and bipolar cautery, neodymium/yttrium aluminum garnet argon laser, radiofrequency ablation or argon plasma coagulation. Despite its relatively common frequency, there is a dearth of existing literature reporting head-to-head comparisons of the various treatment options via a randomized controlled approach. The purpose of our review was to present the reader a consolidation of the existing evidence-based literature with the goal of highlighting the comparative effectiveness and risks of the various treatment approaches. Finally, we outline a pragmatic approach to the treatment of radiation proctitis. In light of the lack of randomized data, our goal is to pursue as least invasive an approach as possible, with escalation of care tailored to the severity of the patient’s symptoms. For those cases that are clinically asymptomatic or only mildly symptomatic, observation or medical management can be considered. Once a patient fails such management or symptoms become more severe, invasive procedures such as endoscopically based focal ablation or surgical intervention can be considered. Although not all recommendations are supported by level I evidence, reported case series and single-institutional studies in the literature suggest that successful treatment with cessation of symptoms can be obtained in the majority of cases. PMID:27610010
Optimizing multimodality treatment for head and neck cancer in rural India.
Trivedi, N P; Trivedi, P; Trivedi, H; Trivedi, S; Trivedi, N
2012-01-01
Multimodality treatment of head and neck cancer in rural India is not always feasible due to lack of infrastructure and logistics. To demonstrate the feasibility of multimodality treatment for head and neck cancer in a community setting in rural India. Community cancer center, retrospective review. This article focuses on practice environment in a cancer clinic in rural India. We evaluated patient profile, treatment protocols, infrastructure availability, factors impacting treatment decisions, cost estimations, completion of treatment, and major treatment-related complications for the patient population treated in our clinic for a 2-year period. A total of 230 head and neck cancer patients were treated with curative intent. Infrastructure support included basic operating room facility (cautery machine, suction, drill system, microscope, and anesthesia machine without ventilator support), blood bank, histopathology laboratory, and computerized tomography machine. Radiation therapy (RT) facility was available in a nearby city, about 75 km away. One hundred and fifty-four (67%) patients presented at an advanced stage, with 138 (60%) receiving multimodality treatment. One hundred and eighty-four (80%) patients underwent primary surgery and 167 (73%) received radiotherapy. Two hundred and twelve (92%) patients completed the treatment, 60 (26%) were lost to follow-up at 18-month median follow-up (range 12-26 months), with 112 patients (66%) being alive, disease free. Totally 142 were major head neck surgeries with 25 free flap reconstructions and 41 regional flaps. There were 15 (6%) major post-op complications and two perioperative mortalities. Average cost of treatment for single modality treatment was approximately 40,000 INR and for multimodality treatment was 80,000 INR. This study demonstrates that it is feasible to provide basic multimodality treatment to head and neck cancer patients in the community.
Connolly, James G; Goldstone, Stephen E
2017-05-01
Anal canal high-grade squamous intraepithelial lesion (HSIL) is the precursor to anal cancer. Immunocompromised patients are at increased risk and disease is usually within 3 cm from the anal verge. High-resolution anoscopy (HRA) with an 8-cm anoscope is used to identify and guide cautery treatment of HSIL. We report three patients with a long-term history of ulcerative colitis (UC) treated with systemic immunomodulators who developed proximally located rectal HSIL. Two patients were HIV-negative women, 63 and 48 years old, and the third was a 51-year-old HIV-positive man with underlying UC for 10, 16, and 3 years, respectively. They each presented with a HPV-positive HSIL visibly extending above the limits of the anoscope used for HRA. None developed cancer. All had episodes of active UC. It is unclear what causative role systemic immunomodulators play in predisposing UC patients to proximal HSIL. HSIL probably developed on a tongue of HPV-infected squamous epithelium growing proximally over the inflamed rectum. Islands developed when areas of squamous epithelium degenerated, creating skip areas. This study highlights the potential for HSIL to extend into the rectum either as a contiguous patch or isolated islands and the need for heightened surveillance in patients with extensive anal canal HSIL treated with immunodulator therapy. HSIL identified at the limit of the anoscope should be investigated further with colonoscopy, and argon plasma coagulation (APC) ablation can serve as an effective treatment option. Patients are at risk for stricture, but it is unclear what role the UC or the ablation played in stricture formation.
NASA Technical Reports Server (NTRS)
Brizzee, K. R.; Ordy, J. M.; Mehler, W. R.
1980-01-01
Twelve young adult squirrel monkeys of the Bolivian subspecies were subjected to continuous counter-clockwise horizontal rotary motion at 25 rpm, together with a sinusoidal vertical excursion of 6 in. every 2 sec (0.5 Hz). Each animal was exposed to this motion regimen for a period of 60 min once each week for three consecutive weeks. Following the third weekly motion test bilateral ablation of the Area Postrema (AP) was performed in eight of the animals by thermal cautery. Two control animals were sham-operated after the third motion test while two additional controls were given the motion tests as noted above but were not operated. The four controls were considered as a single group for statistical analyses of results of the motion tests. After a recovery period of 30 to 40 days, and at a comparable interval in the non-operated controls, each animal was again tested for motion sensitivity for three consecutive weeks. The brains of all of the animals were then fixed by left ventriculal cardiac perfusion with Bouin's fluid and processed for histological evaluation of the bilateral AP ablation in comparison with the control brains. Five of the AP-ablated animals postoperatively were completely refractory to the motion stimuli, two exhibited a decreased number of emetic responses, and one exhibited the same number of responses before and after the AP lesions. The controls exhibited no significant difference in emetic sensitivity on the second series of three weekly tests than on the first series. The results of this investigation appear to be in agreement with the observations of Wang and Chinn in the dog indicating that the integrity of the AP (CTZ) is essential to the emetic response to motion.
Dueland, R T; Adams, W M; Patricelli, A J; Linn, K A; Crump, P M
2010-01-01
To measure one and two year effects of juvenile pubic symphysiodesis (JPS) in puppies defined as 'at-risk' for canine hip dysplasia (CHD) using the following objective hip conformation criteria: Acetabular angle (AA), dorsal acetabular rim angle (DARA) and hip laxity (PennHIP© distraction index (DI). Controlled clinical case study. Thirty-nine dysplastic puppies (six controls). The dogs were anaesthetised and acetabular angle, DARA, and DI values were obtained by computed tomography and radiography preoperatively. Electro-cautery fusion of the pubic symphysis was performed between 12 - 24 weeks of age. The imaging was repeated at one and two years of age. Significant hip improvements were seen at the two-year follow-up appointments for: AA (JPS dogs 31% increase, control 3%), DARA (JPS 38% decrease, control 15%) and DI (JPS 41% decrease in laxity, controls 20%) for all postoperative versus preoperative values. Pubic fusion occurred with minor morbidity. Juvenile pubic symphysiodesis resulted in significant improvements in hip conformation (AA and DARA), especially in mild to moderately lax hips (DI = 0.40-0.69). Most dogs with DI≥0.70 increased in osteoarthritis grade by two years of age. Juvenile pubic symphysiodesis surgery at 12-24 weeks of age significantly improved hip conformation and decreased laxity in at-risk CHD dogs. Early-age (12 to 16 week) recognition of hip laxity offered greater JPS benefits than surgery performed at 19- to 24-weeks-old. Dogs with severe laxity (DI≥0.70) continued to increase in osteoarthritis. An early (12-16 weeks) positive laxity test (Ortolani) should alert one to obtain objective laxity determinations (PennHIP© DI).
Yamamoto, Takumi; Yoshimatsu, Hidehiko; Hayashi, Akitatsu; Koshima, Isao
2015-10-01
The treatment of deep pressure ulcer with a wide wound edge undermining (pocket) is challenging, especially when conservative treatments are ineffective. As most patients with a pressure ulcer suffer from systemic comorbidities, invasive surgery cannot be performed on all patients, and less invasive treatment is required. Less invasive surgical intervention to a deep pressure ulcer, parallel pocket incision (PPI), was performed on 10 patients with intractable pressure ulcers with a pocket formation. In PPI procedures, two parallel skin incisions were made to open up the deepest fold of the pocket and to preserve the skin overlying the pocket lesion; through the created incisions, the necrotic tissues around the deepest fold of the undermining could be easily removed, which facilitated spontaneous wound healing. Postoperative results and complications were evaluated. All PPI procedures were safely performed under local infiltration anesthesia without major postoperative complication; minor bleeding was seen intraoperatively in three patients, which could be easily controlled with electric cautery coagulation. Nine of 10 ulcers were cured after PPI, and one could not be followed up due to the patient's death non-related to the pressure ulcer. For the nine cured patients, the average time for cure was 14.9 weeks, and no recurrence was observed at postoperative 6 months. PPI is a simple, technically easy, and less invasive surgical intervention to an intractable pressure ulcer with a pocket, which can be safely performed under local infiltration anesthesia even on a patient with severe systemic comorbidities. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Miyasaka, Yoshikazu; Suzuki, Kenji; Oh, Shiaki; Takamochi, Kazuya
2015-10-01
Segmentectomy is becoming more common since many lung cancers are small when found. Left upper superior segmentectomy (LUSS) is the most popular procedure for segmentectomy. Atelectasis is a common postoperative complication following segmentectomy. In this study, we sought to better understand atelectasis of the lingular segment following LUSS. Among 265 patients who underwent segmentectomy of the lung at our institute between February 2008 and August 2012, 60 patients who underwent LUSS were investigated retrospectively. An intersegmental plane was created using a stapler in 41 and by cautery in 19. The relationships between atelectasis of the lingular segment and clinical factors were analyzed by multivariate analysis. The clinical factors examined included body mass index, preoperative cardio/thoracic dimension ratio (CTR), preoperative forced expiratory volume in 1 second (FEV1), the method used to make an intersegmental plane, the interval of thoracic drainage, and the degree of lobulation. Atelectasis of the lingular segment was seen in nine (15.0%) patients. Preoperative CTR predicted atelectasis of the lingular segment (p = 0.004). FEV1 was preserved in 73.8% of patients with atelectasis of the lingular segment and in 86.8% of the controls. This difference was significant (p = 0.027). Atelectasis of the middle lobe following RUL was seen in 10/238 (4.2%) within the same period. Preoperative CTR was related to atelectasis of the lingular segment. One of the advantages of segmentectomy is that it enables the postoperative preservation of respiratory function. However, in patients with cardiomegaly, respiratory function following LUSS may be preserved less than expected. Georg Thieme Verlag KG Stuttgart · New York.
Cervical cancer screening in women referred to healthcare centres in Tabriz, Iran.
Farshbaf-Khalili, Azizeh; Salehi-Pourmehr, Hanieh; Shahnazi, Mahnaz; Yaghoubi, Sina; Gahremani-Nasab, Parvaneh
2015-01-01
Cervical cancer is the second most common cancer among Iranian women and among the few cancers that could be easily diagnosed in the pre-malignant stage. We aimed to assess the status of cervical cancer screening in women referred to health care centres in Tabriz, northwest Iran. This descriptive-analytical study was done on 441 women referred to health care centres of Tabriz, northwest Iran. The centres were selected using the multi-stage cluster sampling method. The participants were selected from the active records of those centres. A questionnaire regarding the socio-demographic characteristics and cervical cancer screening and reasons for referring or not referring for screening was completed by the participants A P < 0.05 was considered as significant. Out of the participants 49.4% of women had done the Pap smear test while 50.6% had never done this test. The main reason why women had not performed cervical cancer screening was being unaware of the importance of it (46.1%). Logistic regression analysis with adjustment showed a significant relationship between screening and awareness scores (OR = 1.17, CI = 95%:1.12-1.23), when the effect of other confounding factors [total awareness scores, risk factors (marriage or having sexual intercourse at a young age, history of obvious cervical infection, cautery, cryotherapy or repeated curettage), age and type of family planning] in screening was controlled. Suitable and continuous educational programmes especially for high risk women should be implemented through the health care services. Preparing educational brochures and pamphlets and providing adequate training on the necessity of early referral and marriage counseling could also be effective in improving woman's awareness and performance.
Bozan, Aykut; Eriş, Hüseyin Naim; Dizdar, Denizhan; Göde, Sercan; Taşdelen, Bahar; Alpay, Hayrettin Cengiz
2018-05-18
The most common cause of septoplasty failure is inferior turbinate hypertrophy that is not treated properly. Several techniques have been described to date: total or partial turbinectomy, submucosal resection (surgical or with a microdebrider), with turbinate outfracture being some of those. In this study, we compared the pre- and postoperative lower turbinate volumes using computed tomography in patients who had undergone septoplasty and compensatory lower turbinate turbinoplasty with those treated with outfracture and bipolar cauterization. This retrospective study enrolled 66 patients (37 men, 29 women) who were admitted to our otorhinolaryngology clinic between 2010 and 2017 because of nasal obstruction and who were operated on for nasal septum deviation. The patients who underwent turbinoplasty due to compensatory lower turbinate hypertrophy were the turbinoplasty group; Outfracture and bipolar cauterization were separated as the out fracture group. Compensatory lower turbinate volumes of all patients participating in the study (mean age 34.0±12.4 years, range 17-61 years) were assessed by preoperative and postoperative 2 month coronal and axial plane paranasal computed tomography. The transverse and longitudinal dimensions of the postoperative turbinoplasty group were significantly lower than those of the out-fracture group (p=0.004). In both groups the lower turbinate volumes were significantly decreased (p=0.002, p<0.001 in order). The postoperative volume of the turbinate on the deviated side of the patients was significantly increased: tubinoplasty group (p=0.033). Both turbinoplasty and outfracture are effective volume-reduction techniques. However, the turbinoplasty method results in more reduction of the lower turbinate volume than outfracture and bipolar cauterization. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Box, Geoffrey N; Kaplan, Adam G; Rodriguez, Esequiel; Skarecky, Douglas W; Osann, Kathryn E; Finley, David S; Ahlering, Thomas E
2010-01-01
Whether or not sacrificing accessory pudendal arteries (APAs) during radical prostatectomy affects potency has been an ongoing source of concern. Herein, we present our potency results relative to sacrificing APAs in normally pre-potent men following robot-assisted radical prostatectomy (RARP). The distribution of APAs and clinical characteristics were prospectively recorded in 200 consecutive patients undergoing RARP with a cautery-free technique. Sexual function was assessed using the International Index of Erectile Function 5-item questionnaire (IIEF-5). All APAs were sacrificed due to stapling the dorsal vein complex. Postoperatively, potency was defined by an affirmative answer to the following two questions: "Were erections adequate for penetration?" and "were the erections satisfactory?" Postoperative IIEF-5 scores and quality of erections (% of preoperative firmness: 0%, 25%, 50%, 75%, 100%) were also obtained. Subgroup analysis of patients age < or =65 years with IIEF-5 score of 22-25 was performed. Eighty patients (40%) had APAs. Preoperatively, there was no association with having an APA and normal/abnormal sexual function. Preoperatively, 58/200 were < or =65 years with self-administered IIEF-5 scores of 22-25. Postoperatively, 53/58 (91%) were potent at 24 months follow-up. Nineteen of 58 patients had a sacrificed APA; 39 patients had no APA. Eighteen of 19 (95%) patients with sacrificed APAs were potent vs. 35/39 (90%) with no APA present (P = 0.53). Multivariate analysis showed no significant correlation between sacrificing an APA and time of potency recovery, quality of postoperative erections (94% vs. 90% P = 0.80) or mean IIEF-5 score (22.4 vs. 20.8, P = 0.13). We found no correlation between the presence or absence of APAs and preoperative sexual function. Furthermore, after sacrificing all APAs, we found no correlation with potency return, time to return of potency, quality of erections, or mean IIEF-5 scores at 24 months.
Beaulieu, Daphnée; Barkun, Alan; Martel, Myriam
2012-07-21
To complete a quality audit using recently published criteria from the Quality Assurance Task Group of the National Colorectal Cancer Roundtable. Consecutive colonoscopy reports of patients at average/high risk screening, or with a prior colorectal neoplasia (CRN) by endoscopists who perform 11 000 procedures yearly, using a commercial computerized endoscopic report generator. A separate institutional database providing pathological results. Required documentation included patient demographics, history, procedure indications, technical descriptions, colonoscopy findings, interventions, unplanned events, follow-up plans, and pathology results. Reports abstraction employed a standardized glossary with 10% independent data validation. Sample size calculations determined the number of reports needed. Two hundreds and fifty patients (63.2 ± 10.5 years, female: 42.8%, average risk: 38.5%, personal/family history of CRN: 43.3%/20.2%) were scoped in June 2009 by 8 gastroenterologists and 3 surgeons (mean practice: 17.1 ± 8.5 years). Procedural indication and informed consent were always documented. 14% provided a previous colonoscopy date (past polyp removal information in 25%, but insufficient in most to determine surveillance intervals appropriateness). Most procedural indicators were recorded (exam date: 98.4%, medications: 99.2%, difficulty level: 98.8%, prep quality: 99.6%). All reports noted extent of visualization (cecum: 94.4%, with landmarks noted in 78.8% - photodocumentation: 67.2%). No procedural times were recorded. One hundred and eleven had polyps (44.4%) with anatomic location noted in 99.1%, size in 65.8%, morphology in 62.2%; removal was by cold biopsy in 25.2% (cold snare: 18%, snare cautery: 31.5%, unrecorded: 20.7%), 84.7% were retrieved. Adenomas were noted in 24.8% (advanced adenomas: 7.6%, cancer: 0.4%) in this population with varying previous colonic investigations. This audit reveals lacking reported items, justifying additional research to optimize quality of reporting.
Beaulieu, Daphnée; Barkun, Alan; Martel, Myriam
2012-01-01
AIM: To complete a quality audit using recently published criteria from the Quality Assurance Task Group of the National Colorectal Cancer Roundtable. METHODS: Consecutive colonoscopy reports of patients at average/high risk screening, or with a prior colorectal neoplasia (CRN) by endoscopists who perform 11 000 procedures yearly, using a commercial computerized endoscopic report generator. A separate institutional database providing pathological results. Required documentation included patient demographics, history, procedure indications, technical descriptions, colonoscopy findings, interventions, unplanned events, follow-up plans, and pathology results. Reports abstraction employed a standardized glossary with 10% independent data validation. Sample size calculations determined the number of reports needed. RESULTS: Two hundreds and fifty patients (63.2 ± 10.5 years, female: 42.8%, average risk: 38.5%, personal/family history of CRN: 43.3%/20.2%) were scoped in June 2009 by 8 gastroenterologists and 3 surgeons (mean practice: 17.1 ± 8.5 years). Procedural indication and informed consent were always documented. 14% provided a previous colonoscopy date (past polyp removal information in 25%, but insufficient in most to determine surveillance intervals appropriateness). Most procedural indicators were recorded (exam date: 98.4%, medications: 99.2%, difficulty level: 98.8%, prep quality: 99.6%). All reports noted extent of visualization (cecum: 94.4%, with landmarks noted in 78.8% - photodocumentation: 67.2%). No procedural times were recorded. One hundred and eleven had polyps (44.4%) with anatomic location noted in 99.1%, size in 65.8%, morphology in 62.2%; removal was by cold biopsy in 25.2% (cold snare: 18%, snare cautery: 31.5%, unrecorded: 20.7%), 84.7% were retrieved. Adenomas were noted in 24.8% (advanced adenomas: 7.6%, cancer: 0.4%) in this population with varying previous colonic investigations. CONCLUSION: This audit reveals lacking reported items, justifying additional research to optimize quality of reporting. PMID:22826619
Burn center management of operating room fire injuries.
Haith, Linwood R; Santavasi, Wil; Shapiro, Tyler K; Reigart, Cynthia L; Patton, Mary Lou; Guilday, Robert E; Ackerman, Bruce H
2012-01-01
Approximately 100 operating room (OR) fires occur per year in the United States, with 15% resulting in serious injuries. Intraoperative cautery was frequently associated with OR fires before 1994; however, use of supplemental oxygen (O(2)), ethanol-based products, and disposable drapes have been more frequently associated with OR fires. Fires resulting from cosmetic and other small procedures involving use of nasal canula O(2) and electrocautery have been described in six published reports. We report five thermal injury cases admitted to our burn treatment center because of fires during surgical procedures over a 5-year period. Two patients undergoing supraorbital excision experienced 2.5 and 3% TBSA involvement burns; in a third patient surgical excision of a nasal polyp resulted in a 1% TBSA burn; in a fourth patient an excisional biopsy of a lymph node resulted in a 2.75% TBSA burn; and the last patient was burned during placement of a pacemaker, with resulting TBSA of 10.5%. Two of the five patients required intubation for inhalational injury. Two patients required tangential excision and grafting of their thermal injuries. All patients had received local or parenteral anesthesia with supplemental O(2)/nitrous oxide (N(2)O) for surgical procedure. There are a number of ignition sources in the OR, including electrocautery, lasers, and faulty OR equipment. The risk of OR fires increases with surgical procedures involving the face and neck, including tracheostomy and tracheobronchial surgery. The common use of O(2)/N(2)O mixtures or enriched O(2) for minimally complex surgical procedures and disposable drapes adds to the risk of an OR fire: the O(2)/N(2)O provides a fuel source, and the disposable drapes trap thedelivered gas. Electrocautery near an O(2)/N(2)O source resulted in the five thermal injuries and warrants careful reconsideration of technique for surgical procedures.
[Precancerous lesions of the uterine cervix: morphology and molecular pathology].
Horn, L-C; Klostermann, K
2011-11-01
HPV-induced alterations of the uterine cervix are frequently biopsied because of suspicious findings on a Pap smear and/or colposcopy. Precancerous lesions occur at the so called transformation zone. For those representing squamous differentiation, the traditional three-tier grading system in CIN 1 to 3 is used. CIN 1 and CIN 2 represent (spontaneous) regression in 60-90% and 50%, respectively. In CIN 3 lesions progression is seen in 20-50%. For appropriate grading, improvement of inter- and intraobserver correlation as well as the exclusion of non-precancerous lesions, p16 immunohistochemistry might be helpful. The terms endocervical glandular dysplasia and low-grade glandular intraepithelial neoplasia have been suggested for glandular lesions less than adenocarcinoma in situ (AIS). Until now reproducible histological criteria have not been established. Additional studies using HPV analysis, p16 and Ki-67 immunohistochemistry have not been proved for these lesions. In accordance with international consensus meetings, these diagnostic terms are not recommended for use in practice. AIS, characterised by the replacement of glandular epithelium by cytologically malignant cells, has been established as the precancerous lesion of the endocervix. AIS is much less common than CIN 3 with a reported range of 1:50-100. But, AIS is found in association with CIN 3 with 25-75%. The differential diagnosis between AIS and non-neoplastic glandular lesion may be aided by immunohistochemistry (e.g. p16, Ki-67, bcl-2, vimentin). All specimens obtained after the clinical diagnosis of cervical precancerous lesions should be examined using step sectioning to rule out microinvasive growth. Important information for clinicians includes the quality of the specimen (cautery artefacts, transformation zone enclosed within the probe), exact grading of CIN lesions, identification of other lesions responsible for suspicious findings of a Pap smear or at colposcopy, and in the case of conisation the distance of the lesion from the resection margins (endo- and ectocervical and circumferential margin).
Walsh, Kevin M; Machado, Andre G; Krishnaney, Ajit A
2015-08-01
There is currently no consensus on appropriate perioperative management of patients with spinal cord stimulator implants. Magnetic resonance imaging (MRI) is considered safe under strict labeling conditions. Electrocautery is generally not recommended in these patients but sometimes used despite known risks. The aim was to discuss the perioperative evaluation and management of patients with spinal cord stimulator implants. A literature review, summary of device labeling, and editorial were performed, regarding the safety of spinal cord stimulator devices in the perioperative setting. A literature review was performed, and the labeling of each Food and Drug Administration (FDA)-approved spinal cord stimulation system was reviewed. The literature review was performed using PubMed and the FDA website (www.fda.gov). Magnetic resonance imaging safety recommendations vary between the models. Certain systems allow for MRI of the brain to be performed, and only one system allows for MRI of the body to be performed, both under strict labeling conditions. Before an MRI is performed, it is imperative to ascertain that the system is intact, without any lead breaks or low impedances, as these can result in heating of the spinal cord stimulation (SCS) and injury to the patient. Monopolar electrocautery is generally not recommended for patients with SCS; however, in some circumstances, it is used when deemed required by the surgeon. When cautery is necessary, bipolar electrocautery is recommended. Modern electrocautery units are to be used with caution as there remains a risk of thermal injury to the tissue in contact with the SCS. As with MRI, electrocautery usage in patients with SCS systems with suspected breaks or abnormal impedances is unsafe and may cause injury to the patient. Spinal cord stimulation is increasingly used in patients with pain of spinal origin, particularly to manage postlaminectomy syndrome. Knowledge of the safety concerns of SCS and appropriate perioperative evaluation and management of the SCS system can reduce risks and improve surgical planning. Copyright © 2015 Elsevier Inc. All rights reserved.
Fornalik, Hubert; Zore, Temeka; Fornalik, Nicole; Foster, Todd; Katschke, Adrian; Wright, Gary
2018-06-01
This study aimed to compare surgical outcomes and the adequacy of surgical staging in morbidly obese women with a body mass index (BMI) of 40 kg/m or greater who underwent robotic surgery or laparotomy for the staging of endometrioid-type endometrial cancer. This is a retrospective cohort study of patients who underwent surgical staging between May 2011 and June 2014. Patients' demographics, surgical outcomes, intraoperative and postoperative complications, and pathological outcomes were compared. Seventy-six morbidly obese patients underwent robotic surgery, and 35 underwent laparotomy for surgical staging. Robotic surgery was associated with more lymph nodes collected with increasing BMI (P < 0.001) and decreased chances for postoperative respiratory failure and intensive care unit admissions (P = 0.03). Despite a desire to comprehensively stage all patients, we performed successful pelvic and paraaortic lymphadenectomy in 96% versus 89% (P = 0.2) and 75% versus 60% (P = 0.12) of robotic versus laparotomy patients, respectively. In the robotic group, with median BMI of 47 kg/m, no conversions to laparotomy occurred. The robotic group experienced less blood loss and a shorter length of hospital stay than the laparotomy group; however, the surgeries were longer. In a high-volume center, a high rate of comprehensive surgical staging can be achieved in patients with BMI of 40 kg/m or greater either by laparotomy or robotic approach. In our experience, robotic surgery in morbidly obese patients is associated with better quality staging of endometrial cancer. With a comprehensive approach, a professional bedside assistant, use of a monopolar cautery hook, and our protocol of treating morbidly obese patients, robotic surgeries can be safely performed in the vast majority of patients with a BMI of 40 kg/m or greater, with lymph node counts being similar to nonobese patients, and with conversions to laparotomy reduced to a minimum.
Fornalik, Hubert; Zore, Temeka; Fornalik, Nicole; Foster, Todd; Katschke, Adrian; Wright, Gary
2018-01-01
Objective This study aimed to compare surgical outcomes and the adequacy of surgical staging in morbidly obese women with a body mass index (BMI) of 40 kg/m2 or greater who underwent robotic surgery or laparotomy for the staging of endometrioid-type endometrial cancer. Methods This is a retrospective cohort study of patients who underwent surgical staging between May 2011 and June 2014. Patients' demographics, surgical outcomes, intraoperative and postoperative complications, and pathological outcomes were compared. Results Seventy-six morbidly obese patients underwent robotic surgery, and 35 underwent laparotomy for surgical staging. Robotic surgery was associated with more lymph nodes collected with increasing BMI (P < 0.001) and decreased chances for postoperative respiratory failure and intensive care unit admissions (P = 0.03). Despite a desire to comprehensively stage all patients, we performed successful pelvic and paraaortic lymphadenectomy in 96% versus 89% (P = 0.2) and 75% versus 60% (P = 0.12) of robotic versus laparotomy patients, respectively. In the robotic group, with median BMI of 47 kg/m2, no conversions to laparotomy occurred. The robotic group experienced less blood loss and a shorter length of hospital stay than the laparotomy group; however, the surgeries were longer. Conclusions In a high-volume center, a high rate of comprehensive surgical staging can be achieved in patients with BMI of 40 kg/m2 or greater either by laparotomy or robotic approach. In our experience, robotic surgery in morbidly obese patients is associated with better quality staging of endometrial cancer. With a comprehensive approach, a professional bedside assistant, use of a monopolar cautery hook, and our protocol of treating morbidly obese patients, robotic surgeries can be safely performed in the vast majority of patients with a BMI of 40 kg/m2 or greater, with lymph node counts being similar to nonobese patients, and with conversions to laparotomy reduced to a minimum. PMID:29621128
The role of intraoperative ultrasound in small renal mass robotic enucleation.
Gunelli, Roberta; Fiori, Massimo; Salaris, Cristiano; Salomone, Umberto; Urbinati, Marco; Vici, Alexia; Zenico, Teo; Bertocco, Mauro
2016-12-30
As a result of the growing evidence on tumor radical resection in literature, simple enucleation has become one of the best techniques associated to robotic surgery in the treatment of renal neoplasia, as it guarantees minimal invasiveness and the maximum sparing of renal tissue, facilitating the use of reduced or zero ischemia techniques during resection. The use of a robotic ultrasound probe represents a useful tool to detect and define tumor location, especially in poorly exophytic small renal mass. A total of 22 robotic enucleations were performed on < 3 cm renal neoplasias (PADUA score 18 Pz 6/7 e 4 Pz 8) using a 12-5 MHz robotic ultrasound probe (BK Drop-In 8826). Once kidney had been isolated from the adipose capsule at the site of the neoplasia (2), the exact position of the lesion could be easily identified in all cases (22/22), even for mostly endophytic lesions, thanks to the insertion of the ultrasound probe through the assistant port. Images were produced and visualized by the surgeon using the TilePro feature of the DaVinci surgical system for producing a picture-in-picture image on the console screen. The margins of resection were then marked with cautery, thus allowing for speedy anatomical dissection. This reduced the time of ischemia to 8 min (6-13) and facilitated the enucleation technique when performed without clamping the renal peduncle (6/22). No complications due to the use of the ultrasound probe were observed. The use of an intraoperative robotic ultrasound probe has allowed for easier identification of small, mostly endophytic neoplasias, better anatomical approach, shorter ischemic time, reduced risk of pseudocapsule rupture during dissection, and easier enucleation in cases performed without clamping. It is noteworthy that the use of intraoperative ultrasound probe allows mental reconstruction of the tumor through an accurate 3D vision of the hidden field during surgical dissection.
GPU-based Efficient Realistic Techniques for Bleeding and Smoke Generation in Surgical Simulators
Halic, Tansel; Sankaranarayanan, Ganesh; De, Suvranu
2010-01-01
Background In actual surgery, smoke and bleeding due to cautery processes, provide important visual cues to the surgeon which have been proposed as factors in surgical skill assessment. While several virtual reality (VR)-based surgical simulators have incorporated effects of bleeding and smoke generation, they are not realistic due to the requirement of real time performance. To be interactive, visual update must be performed at least 30 Hz and haptic (touch) information must be refreshed at 1 kHz. Simulation of smoke and bleeding is, therefore, either ignored or simulated using highly simplified techniques since other computationally intensive processes compete for the available CPU resources. Methods In this work, we develop a novel low-cost method to generate realistic bleeding and smoke in VR-based surgical simulators which outsources the computations to the graphical processing unit (GPU), thus freeing up the CPU for other time-critical tasks. This method is independent of the complexity of the organ models in the virtual environment. User studies were performed using 20 subjects to determine the visual quality of the simulations compared to real surgical videos. Results The smoke and bleeding simulation were implemented as part of a Laparoscopic Adjustable Gastric Banding (LAGB) simulator. For the bleeding simulation, the original implementation using the shader did not incur in noticeable overhead. However, for smoke generation, an I/O (Input/Output) bottleneck was observed and two different methods were developed to overcome this limitation. Based on our benchmark results, a buffered approach performed better than a pipelined approach and could support up to 15 video streams in real time. Human subject studies showed that the visual realism of the simulations were as good as in real surgery (median rating of 4 on a 5-point Likert scale). Conclusions Based on the performance results and subject study, both bleeding and smoke simulations were concluded to be efficient, highly realistic and well suited in VR-based surgical simulators. PMID:20878651
Robotic transanal endoscopic microsurgery: technical details for the lateral approach.
Buchs, Nicolas C; Pugin, François; Volonte, Francesco; Hagen, Monika E; Morel, Philippe; Ris, Frederic
2013-10-01
Transanal endoscopic microsurgery is a minimally invasive approach reserved for the resection of selected rectal tumors. However, this approach is technically demanding. Although robotic technology may overcome the limitations of this approach, the system can be difficult to dock, especially in the lithotomy position. The study aim is thus to report the technical details of robotic transanal endoscopic microsurgery with the use of a lateral approach. This study is a prospective evaluation of robotic transanal endoscopic microsurgery in a single tertiary institution, under a protocol approved by our local ethics committee. Patients underwent a routine mechanical bowel preparation and were placed in the left or right lateral position according to the tumor location. A circular anal dilatator was used together with the glove port technique. The robotic system was then docked over the hip. A 30° optic and 2 articulated instruments were used with an additional assistant trocar. The tumor excision was realized with an atraumatic grasper and an articulated cautery hook, and the defect was closed with barbed continuous stiches in each case. The primary outcome was the safety and feasibility of the procedure. Three patients underwent a robotic transanal endoscopic microsurgery with the use of the lateral approach. Mean operative time was 110 minutes, including 20 minutes for the docking of the robot. There was 1 intraoperative complication (a pneumoperitoneum without intraabdominal lesion) and no postoperative complications. Mean hospital stay was 3 days. Margins were negative in all the cases. The study was limited by the small number of patients. Robotic transanal endoscopic microsurgery with use of the lateral approach is feasible and may facilitate the local resection of small lesions of the mid and lower rectum. It might assume an important place in sphincter-preserving surgery, especially for selected and early rectal cancer (see Video, Supplemental Digital Content 1, http://links.lww.com/DCR/A114).
Jin, Cheng-Hua; Liu, Kai; Yu, Kai-Zhong; Tian, Hui; Mao, Zheng-Chun; Shen, Wei-Yu
2014-08-01
The objective of this study is to assess the use of a novel, double-lumen electrocautery tube (DLET) device for ablating the sympathetic nerve chain in patients with primary palmar hyperhidrosis (PPH). Forty-six patients with severe PPH were recruited into the study between November 2010 and February 2012. All patients underwent single port, bilateral video-assisted thoracoscopic sympathicotomy. Twenty-four patients were randomized to receive sympathicotomy using a conventional 5-mm electrocautery hook (hook group) and 22 patients were randomized to the DLET group. The mean postoperative follow-up period was 8.1 months (range: 1 to 15 months). After surgery the hands of all patients became dry and warm. Mean incision size was 10.6 ± 1.0 in the hook group and 6.5 ± 0.5 mm in the DLET group (p = 0.001). The mean pain score was 1.4 ± 0.6 with hook surgery and 0.9 ± 0.6 with the DLET device (p = 0.016). The mean operative time was longer in the hook group (36.8 ± 3.4 min) than in the DLET group (30.5 ± 3.9 min; p = 0.001). There were no significant differences between the two procedures in terms of hospital stay and compensatory sweating, or patient satisfaction. Pneumothorax occurred in two (8.3%) patients in the hook group and in one (4.5%) patient in the DLET group. None of the patients required chest drainage and none developed Horner syndrome. Single-port video-assisted thoracoscopic sympathicotomy using hook or DLET procedures is effective, safe, and minimally invasive method for palmar hyperhidrosis. The DLET device allows a shorter operation time, smaller incision, better cosmetic results, less pain, and better clarity of video, making it suitable for single-port thoracoscopic sympathicotomy. Georg Thieme Verlag KG Stuttgart · New York.
Lin, David; Soetikno, Roy M; McQuaid, Kenneth; Pham, Chi; Doan, Gilbert; Mou, Shanshan; Shergill, Amandeep K; Somsouk, Ma; Rouse, Robert V; Kaltenbach, Tonya
2018-04-01
Balancing the risks for thromboembolism and postpolypectomy bleeding in patients requiring anticoagulation and antiplatelet agents is challenging. We investigated the incidence and risk factors for postpolypectomy bleeding on anticoagulation, including heparin bridge and other antithrombotic therapy. We performed a retrospective cohort and case control study at 2 tertiary-care medical centers from 2004 to 2012. Cases included male patients on antithrombotics with hematochezia after polypectomy. Nonbleeding controls were matched to cases 3 to 1 by antithrombotic type, study site, polypectomy technique, and year of procedure. Our outcomes were the incidence and risk factors for postpolypectomy bleeding. There were 59 cases and 174 matched controls. Postpolypectomy bleeding occurred in 14.9% on bridge anticoagulation. This was significantly higher than the overall incidence of bleeding on antithrombotics at 1.19% (95% confidence interval, 0.91%-1.54%) (59/4923). We identified similarly low rates of bleeding in patients taking warfarin (0.66%), clopidogrel (0.84%), and aspirin (0.92%). Patients who bled tended to have larger polyps (13.9 vs 7.3 mm; P < .001) and more polyps ≥2 cm (41% vs 10%; P < .001). Bleeding risk was increased with restarting antithrombotics within 1 week postpolypectomy (odds ratio [OR] 4.50; P < .001), having polyps ≥2 cm (OR 5.94; P < .001), performing right-sided cautery (OR 2.61; P = .004), and having multiple large polyps (OR 2.92; P = .001). Among patients on warfarin, the presence of bridge anticoagulation was an independent risk factor for postpolypectomy bleeding (OR 12.27; P = .0001). We conclude that bridge anticoagulation is associated with a high incidence of postpolypectomy bleeding and is an independent risk factor for hemorrhage compared with patients taking warfarin alone. A higher threshold to use bridge anticoagulation should be considered in patients with an elevated bleeding risk. Copyright © 2018. Published by Elsevier Inc.
Sommer, Doron D; Arbab-Tafti, Sadaf; Farrokhyar, Forough; Tewfik, Marc; Vescan, Allan; Witterick, Ian J; Rotenberg, Brian; Chandra, Rakesh; Weitzel, Erik K; Wright, Erin; Ramakrishna, Jayant
2018-02-27
The goal of this study was to develop and evaluate the impact of an aviation-style challenge and response sinus surgery-specific checklist on potential safety and equipment issues during sinus surgery at a tertiary academic health center. The secondary goal was to assess the potential impact of use of the checklist on surgical times during, before, and after surgery. This initiative is designed to be utilized in conjunction with the "standard" World Health Organization (WHO) surgical checklist. Although endoscopic sinus surgery is generally considered a safe procedure, avoidable complications and potential safety concerns continue to occur. The WHO surgical checklist does not directly address certain surgery-specific issues, which may be of particular relevance for endoscopic sinus surgery. This prospective observational pilot study monitored compliance with and compared the occurrence of safety and equipment issues before and after implementation of the checklist. Forty-seven consecutive endoscopic surgeries were audited; the first 8 without the checklist and the following 39 with the checklist. The checklist was compiled by evaluating the patient journey, utilizing the available literature, expert consensus, and finally reevaluation with audit type cases. The final checklist was developed with all relevant stakeholders involved in a Delphi method. Implementing this specific surgical checklist in 39 cases at our institution, allowed us to identify and rectify 35 separate instances of potentially unsafe, improper or inefficient preoperative setup. These incidents included issues with labeling of topical vasoconstrictor or injectable anesthetics (3, 7.7%) and availability, function and/or position of video monitors (2, 5.1%), endoscope (6, 15.4%), microdebrider (6, 15.4%), bipolar cautery (6, 15.4%), and suctions (12, 30.8%). The design and integration of this checklist for endoscopic sinus surgery, has helped improve efficiency and patient safety in the operating room setting. © 2018 ARS-AAOA, LLC.
[Water-cooled laser sealing of lung tissue in an ex-vivo ventilated porcine lung model].
Tonoyan, T; Prisadov, G; Menges, P; Herrmann, K; Bobrov, P; Linder, A
2014-06-01
Laser resections of lung metastases are followed by air leaks from the parenchymal defect. Large surfaces after metastasectomy are closed by sutures or sealants while smaller areas are frequently sealed thermally by cautery or laser. In this study two different techniques of thermal sealing of lung tissue with laser light are investigated. Carbonisation of lung tissue during thermal sealing appears at temperatures higher than 180 °C. Hypothetically this is contraproductive to haemo- as well as to pneumostasis. In this experimental study thermal laser sealing with and without carbonisation is investigated. In one series tissue temperatures higher than 100 °C are avoided by water dropping from the tip of the light guide onto the parenchymal leak. In the other series carbonisation appeared because the laser light was applied in the non-contact mode without tissue cooling. The characteristics of the laser were 40 W, 1350 nm continuous mode. Air leaks (Vt) were measured with a simple and fast technique with high precision. The sealing effect of either series was defined as S = (1-Vt/V0) and the difference of S was statistically examined. The basic values V0 before sealing were about the same in both series. The air leaks Vt after 15, 30 and 45 s of sealing varied significantly in both series (p = 0.03). During simultaneous cooling the sealing effect was increasing with the duration of laser application, while it became worse in the series without cooling. Histological examination of the sealing zone showed only coagulation of the tissue, while ruptured alveolae could be seen more often in the non-cooled sealing area. It could be shown in the ex-vivo lung model that laser sealing of parenchymal leaks is improved by simultaneous cooling during laser application. Non cooled laser sealing seems to heat up the tissue abruptly and create carbonisation followed by multiple ruptures of alveola and small airways. In accordance with our clinical experience this experimental study confirms that laser sealing for pneumostasis after metastasectomy can be improved by simultaneously cooling the resection area when treated with the laser. Georg Thieme Verlag KG Stuttgart · New York.
Dermal Discolorations and Burns at Neuromonitoring Electrodes in Pediatric Spine Surgery.
Sanders, Austin; Andras, Lindsay; Lehman, Alison; Bridges, Nancy; Skaggs, David L
2017-01-01
Prospective review of consecutive patients. To evaluate the incidence and raise awareness of electrode discoloration that can occur in the operating room when using neuromonitoring. To our knowledge there are no articles that discuss dermal discolorations following spine surgery. Following recognition of dermal discolorations in some patients, a prospective evaluation of all patients undergoing spine surgery with somatosensory-evoked potential and motor-evoked potential neuromonitoring using subdermal needle electrodes was carried out over a 16-month period for quality assurance and improvement. A total of 201 consecutive patients with mean age of 14 years (4-25) were prospectively evaluated. Sixteen percent (33/201) had dermal discolorations associated with neuromonitoring. There were no significant differences in mean age (P = 0.624), height (P = 0.308), weight (P = 0.899), or body mass index (P = 0.571) between the patients with and without dermal discolorations. There was also no difference in prevalence of dermal discoloration by diagnosis (P = 0.490) or location of grounding pad and occurrence of dermal discoloration between groups (P = 0.268). The only difference noted was that patients without dermal discoloration had an average monopolar cautery setting of 46.8 W compared to 40.5 W for patients with dermal discolorations (P = 0.042). Of the 33 patients with a dermal discoloration, 27% (9/33) of these were on both the upper and lower extremities, 21% (7/33) on only the upper extremities, and 52% (17/33) on only the lower extremities. None of the dermal discolorations were painful or tender, and all resolved by 6-month follow-up. One patient did not have any dermal discoloration but did experience two full-thickness burns around the electrodes in one leg. The incidence of burns in this series was 0.5% (1/201). Dermal discolorations occurred in 16% of patients undergoing neuromonitoring for spine surgery. These common discolorations were painless and resolved by 6 months. More significant burns were uncommon, occurring in less than 1%. 3.
Post-tonsillectomy hemorrhage--some facts will never change.
Windfuhr, Jochen P; Verspohl, Berit C; Chen, Yue-Shih; Dahm, Julia D; Werner, Jochen A
2015-05-01
Bleeding remains the most significant complication following tonsillectomy (TE), sometimes requiring revision surgery under general anesthesia. This study was undertaken to verify whether or not bleeding rates changed after bipolar coagulation was replaced by suture ligation to achieve hemostasis at a single institution. The charts of all patients who had undergone tonsillectomy between April 1, 2007, and April 30, 2013, at our institution were reviewed. The tonsils were bluntly dissected with scissors and a rasp. While hemostasis was achieved with bipolar coagulation during the first 36 months (group A), this method was replaced after a transition period of 1 month by intraoperative suture ligation (group B) during the last 36 months. Group A encompassed 2,137 patients including 963 children scheduled for adenotonsillectomy (ATE), and group B consisted of 1,521 patients and included 435 ATE cases. Bleeding from the tonsillar wounds occurred in 111/2,137 group A (5.2 %) and 68/1,521 group B patients (4.5 %). The difference was not found to be significant (p = 0.317). The incidence of primary bleeding (PB) and secondary bleeding (SB) was significantly (p = 0,000) associated with the method to achieve hemostasis: PB prevailed in group B and SB prevailed in group A. The overall incidence of post-tonsillectomy hemorrhage (PTH) varied at different ages, but the difference was not significant in group A (p = 0.401) and group B (p = 0.661). Repeated episodes of PTH occurred in 11/111 group A (9.9 %) and 8/68 group B (11.7 %) patients. The statistical difference was not found to be significant (p = 0.725). However, there were significantly more male patients with bleeding complications in both groups. Despite the strongest efforts to avoid it, the potential risk of PTH remains a fact to be accepted by surgeons and patients. An increased surgical precision achieved by introduction of a surgical microscope as well as replacing bipolar cautery by suture ligation to achieve hemostasis could only reduce the overall rate of PTH. Another fact remains unchanged: PB occurs predominantly when electrosurgical means are avoided and SB prevails, whenever surgeons use them. We will continue our research on refined methods of cold steel microsurgical TE including suture techniques.
Real-time continuous image-guided surgery: Preclinical investigation in glossectomy.
Tabanfar, Reza; Qiu, Jimmy; Chan, Harley; Aflatouni, Niousha; Weersink, Robert; Hasan, Wael; Irish, Jonathan C
2017-10-01
To develop, validate, and study the efficacy of an intraoperative real-time continuous image-guided surgery (RTC-IGS) system for glossectomy. Prospective study. We created a RTC-IGS system and surgical simulator for glossectomy, enabling definition of a surgical target preoperatively, real-time cautery tracking, and display of a surgical plan intraoperatively. System performance was evaluated by a group of otolaryngology residents, fellows, medical students, and staff under a reproducible setting by using realistic tongue phantoms. Evaluators were grouped into a senior and a junior group based on surgical experience, and guided and unguided tumor resections were performed. National Aeronautics and Space Administration Task Load Index (NASA-TLX) scores and a Likert scale were used to measure workloads and impressions of the system, respectively. Efficacy was studied by comparing surgical accuracy, time, collateral damage, and workload between RTC-IGS and non-navigated resections. The senior group performed more accurately (80.9% ± 3.7% vs. 75.2% ± 5.5%, P = .28), required less time (5.0 ± 1.3 minutes vs. 7.3 ± 1.2 minutes, P = .17), and experienced lower workload (43 ± 2.0 vs. 64.4 ± 1.3 NASA-TLX score, P = .08), suggesting a trend of construct validity. Impressions were favorable, with participants reporting the system is a valuable practice tool (4.0/5 ± 0.3) and increases confidence (3.9/5 ± 0.4). Use of RTC-IGS improved both groups' accuracy, with the junior group improving from 64.4% ± 5.4% to 75.2% ± 5.5% (P = .01) and the senior group improving from 76.1% ± 4.5% to 80.9% ± 3.7% (P = .16). We created an RTC-IGS system and surgical simulator and demonstrated a trend of construct validity. Our navigated simulator allows junior trainees to practice glossectomies outside the operating room. In all evaluators, navigation assistance resulted in increased surgical accuracy. NA Laryngoscope, 127:E347-E353, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Alexander, M.; Garbus, H.; Smith, A.L.; Rosenkrantz, T. S.; Fitch, R.H.
2014-01-01
Hypoxia-ischemia (HI) occurs when blood and/or oxygen delivery to the brain is compromised. HI injuries can occur in infants born prematurely (<37 weeks gestational age) or at very low birth weight (<1500 grams), as well as in term infants with birth complications. In both preterm and term HI populations, brain injury is associated with subsequent behavioral deficits. Neonatal HI injury can be modeled in rodents (e.g., the Rice-Vannucci method, via cautery of right carotid followed by hypoxia). When this injury is induced early in life (between postnatal day (P)1–5), neuropathologies typical of human preterm HI are modeled. When injury is induced later (P7–12), neuropathologies typical of those seen in HI term infants are modeled. The current study sought to characterize the similarities/differences between outcomes following early (P3) and late (P7) HI injury in rats. Male rats with HI injury on P3 or P7, as well as sham controls, were tested on a variety of behavioral tasks in both juvenile and adult periods. Results showed that P7 HI rats displayed deficits on motor learning, rapid auditory processing (RAP), and other learning/memory tasks, as well as a reduction in volume in various neuroanatomical structures. P3 HI animals showed only transient deficits on RAP tasks in the juvenile period (but not in adulthood), yet robust deficits on a visual attention task in adulthood. P3 HI animals did not show any significant reductions in brain volume that we could detect. These data suggest that: 1) behavioral deficits following neonatal HI are task-specific depending on timing of injury; 2) P3 HI rats showed transient deficits on RAP tasks; 3) the more pervasive behavioral deficits seen following P7 HI injury were associated with substantial global tissue loss; and 4) persistent deficits in attention in P3 HI subjects might be linked to neural connectivity disturbances rather than a global loss of brain volume, given that no such pathology was found. These combined findings can be applied to our understanding of differing long-term outcomes following neonatal HI injury in premature versus term infants. PMID:24185032
The Burnia: Laparoscopic Sutureless Inguinal Hernia Repair in Girls.
Novotny, Nathan M; Puentes, Maria C; Leopold, Rodrigo; Ortega, Mabel; Godoy-Lenz, Jorge
2017-04-01
Laparoscopic inguinal hernia repair in children is in evolution. Multiple methods of passing the suture around the peritoneum at the level of the internal inguinal ring exist. Cauterization of the peritoneum at the internal ring is thought to increase scarring and decrease recurrence. We have employed a sutureless, cautery only, laparoscopic single port repair of inguinal hernias and patent processus vaginalis (PPV) in girls. After institutional ethical review was obtained, a retrospective review of sutureless laparoscopic inguinal hernia repairs in girls by 4 surgeons at separate institutions was performed. Patient demographics, intraoperative findings, and postoperative outcomes were recorded and analyzed. The technique involves an umbilical 30° camera and either a separate 3 mm stab incision in the midclavicular line or a 3 mm Maryland grasper placed next to the camera, and the distal most portion of the hernia sac is grasped and pulled into the abdomen and cauterized obliterating the sac. Eighty inguinal hernias were repaired using this technique in 67 girls between July 2009 and September 2015. The ages and weights ranged from 1 month to 16 years and from 2 to 69 kg, respectively. There was one conversion to open approach because an incarcerated ovary was too close to the ring. A single umbilical incision was utilized in 85%. Fifty-seven percent patients had hernias on the right whereas 42% had hernias on the left. Of the patients with presumed unilateral hernias, 22 patients were found to have PPV and were treated through the same incisions, 17/22 were found during a contralateral hernia surgery and 5/22 were found incidentally during appendectomy. Average operative time for unilateral and bilateral hernias was 22 minutes (5-38 minutes) and 31 minutes (11-65 minutes), respectively. No patient required a hospital stay because of the hernia repair. At an average of 25 months follow-up (1.6-75 months), there were no recurrences. The only complication was a single lateral port site hernia on a 2 kg, former 24 week postmenstrual age girl before adapting the technique to single-site surgery for all. Laparoscopic sutureless inguinal hernia repair is safe and effective in girls of all ages. The single-site modification allows for superior cosmetic result and lower complication profile. The Burnia allows for adequate treatment of unilateral and bilateral inguinal hernias with a single incision in the umbilicus.
Alexander, M; Garbus, H; Smith, A L; Rosenkrantz, T S; Fitch, R H
2014-02-01
Hypoxia-ischemia (HI) occurs when blood and/or oxygen delivery to the brain is compromised. HI injuries can occur in infants born prematurely (<37 weeks gestational age) or at very low birth weight (<1500 g), as well as in term infants with birth complications. In both preterm and term HI populations, brain injury is associated with subsequent behavioral deficits. Neonatal HI injury can be modeled in rodents (e.g., the Rice-Vannucci method, via cautery of right carotid followed by hypoxia). When this injury is induced early in life (between postnatal day (P)1-5), neuropathologies typical of human preterm HI are modeled. When injury is induced later (P7-12), neuropathologies typical of those seen in HI term infants are modeled. The current study sought to characterize the similarities/differences between outcomes following early (P3) and late (P7) HI injury in rats. Male rats with HI injury on P3 or P7, as well as sham controls, were tested on a variety of behavioral tasks in both juvenile and adult periods. Results showed that P7 HI rats displayed deficits on motor learning, rapid auditory processing (RAP), and other learning/memory tasks, as well as a reduction in volume in various neuroanatomical structures. P3 HI animals showed only transient deficits on RAP tasks in the juvenile period (but not in adulthood), yet robust deficits on a visual attention task in adulthood. P3 HI animals did not show any significant reductions in brain volume that we could detect. These data suggest that: (1) behavioral deficits following neonatal HI are task-specific depending on timing of injury; (2) P3 HI rats showed transient deficits on RAP tasks; (3) the more pervasive behavioral deficits seen following P7 HI injury were associated with substantial global tissue loss; and (4) persistent deficits in attention in P3 HI subjects might be linked to neural connectivity disturbances rather than a global loss of brain volume, given that no such pathology was found. These combined findings can be applied to our understanding of differing long-term outcomes following neonatal HI injury in premature versus term infants. Published by Elsevier B.V.
Banc-Husu, Anna M; Ahmad, Nuzhat A; Chandrasekhara, Vinay; Ginsberg, Gregory G; Jaffe, David L; Kochman, Michael L; Rajala, Michael W; Mamula, Petar
2017-04-01
Gastrointestinal bleeding is one of the most common indications for urgent endoscopy in the pediatric setting. The majority of these procedures are performed for control of variceal bleeding, with few performed for nonvariceal upper gastrointestinal (NVUGI) bleeding. The data on therapeutic endoscopy for NVUGI are sparse. The aims of our study were to review our experience with NVUGI bleeding, describe technical aspects and outcomes of therapeutic endoscopy, and determine gastroenterology fellows' training opportunities according to the national training guidelines. We performed a retrospective review of endoscopy database (Endoworks, Olympus Inc, Center Valley, PA) from January 2009 to December 2014. The search used the following keywords: bleeding, hematemesis, melena, injection, epinephrine, cautery, clip, and argon plasma coagulation. The collected data included demographics, description of bleeding lesion and medical/endoscopic therapy, rate of rebleeding, relevant laboratories, physical examination, and need for transfusion and surgery. The study was approved by the institutional review board. During the study period 12,737 upper endoscopies (esophagogastroduodenoscopies) were performed. A total of 15 patients underwent 17 esophagogastroduodenoscopies that required therapeutic intervention to control bleeding (1:750 procedures). The mean ± standard deviation (median) age of patients who required endoscopic intervention was 11.6 ± 6.0 years (14.0 years). Seven out of 17 patients received dual therapy to control the bleeding lesions. All but 3 patients received medical therapy with intravenous proton pump inhibitor, and 3 received octreotide infusions. Six of the patients experienced rebleeding (40%), with 4 out of 6 initially only receiving single modality therapy. Two of these patients eventually required surgical intervention to control bleeding and both patients presented with bleeding duodenal ulcers. There were no cases of aspiration, perforation, or deaths. There were a total of 24 fellows trained in our program during the study period. Less than 1 therapeutic endoscopy per fellow for NVUGI bleeding was performed. NVUGI bleeding requiring therapeutic endoscopic intervention is rare in pediatrics. A high rate (40%) of rebleeding was noted with a large proportion (66%) of patients receiving single modality therapy. Two patients required surgical intervention to control bleeding and both presented with bleeding duodenal ulcers. An insufficient number of therapeutic procedures is available for adequate fellow training requiring supplemental simulator and hands-on animal model, or adult endoscopy unit training.
Donnez, J; Nisolle, M
1989-09-01
Used endoscopically, the CO2 laser offers some advantages over other operative techniques for endometriosis and adhesions but, in spite of the continuing development of new instrumentation there are still problems with the system. The technique needs specialized equipment requiring ongoing biomedical maintenance and specialized technical care in the operating room. Some problems such as the intraperitoneal accumulation of smoke, gas leakage, and difficulty with maintenance of proper beam alignment still occur. In spite of these problems the advantages are numerous: the system allows precise bloodless destruction of diseased tissue and eliminates the risks of cautery. In the hands of an experienced laparoscopist, it appears safe and effective in vaporization of endometriotic lesions, utero-sacral neurectomy, adhesiolysis and salpingostomy. The judicious use of these techniques, combined with carefully planned further investigations by well-trained and experienced laparoscopists and continuing improvements in the delivery systems, will soon reveal the true efficacy of the CO2 laser laparoscope. If studies continue to show pregnancy rates and pain relief to be equivalent to those patients treated by laparotomy, CO2 laser laparoscopy will become the preferred procedure for the management of pelvic endometriosis and its associated adhesions, distal tubal occlusion, pelvic pain and tubal pregnancy. With the exception of using the argon laser to treat endometriosis, the selective absorption characteristic of lasers has not been greatly utilized. While the CO2 laser is heavily absorbed by water and hence vaporizes most cells in a rather indiscriminate fashion, this is not true for other wavelengths, such as argon, Nd-YAG, KTP, krypton, xenon, copper and gold vapour lasers. The energy form of each of these lasers has different properties of penetration, absorption, reflection and heat dissipation. Many of these lasers have not yet been evaluated in human subjects. An exciting, although not new, area of possible laser application involves the use of photosensitizers and fluorescing agents (Dougherty et al, 1978). Some recent experimental studies (Schellhas and Schneider, 1986; Schneider et al, 1988) may lead to new therapeutic possibilities. The surgical laser is not, however, a panacea. Only controlled trials carried out carefully over the next few years will clearly define its potential. In the meantime it is incumbent upon all of us to investigate the clinical, gynaecological and surgical applications in a careful, methodical and scientific manner.
Relationship of area postrema to three putative measures of motion sickness
NASA Technical Reports Server (NTRS)
Sutton, R.; Fox, Robert A.; Daunton, Nancy G.
1991-01-01
Although the rat has an incomplete emetic reflex, several species-specific responses to motion were proposed as measures of 'motion sickness' in rats. The purpose was to determine the dependence of these responses on one of several neural structures known to be essential to motion-induced vomiting in species with a complete emetic reflex. The Area Postrema (AP) was shown to play an important role in the production of motion sickness in vomiting species. The effects of thermo-cautery ablations of the AP on three different responses supposedly reflecting motion sickness in the rat were compared: conditioned taste aversion (CTA); drinking suppression; and fecal boli. Efficacy of the ablations was determined by subjecting ablated, sham-operated, and unoperated control animals to a CTA test which is known to require a functional AP. Animals with AP ablations failed to form CTA when 0.15 M LiCl was paired with a 10 percent sucrose solution, while sham-operated control subjects conditioned as well as the unoperated control subjects. The extent of the ablations was evaluated histologically at the end of the experiment. To determine the effects of the ablations on the measures of motion sickness, all animals were subjected to rotation for 30 min or 90 min on a platform displaced 20 deg from earth horizontal. Results indicate that ablation of AP in the rat has no effect on the formation of CTA to a 4 percent solution of cider paired with motion, on the suppression of drinking immediately after exposure to motion, or on the frequency of fecal boli during exposure to motion. This failure of AP ablations to eliminate the effects of motion on any of these responses discourages their use as equivalents of motion-induced vomiting. The appropriateness of other suggested measures, e.g., pica, remains untested but the dependence of such measures on stimulation more severe than commonly used in motion sickness research and the absence of a demonstration of their dependence on neural structures essential to motion sickness in vomiting species, suggest caution in the use of such responses. Further, until more is known about the neural structures underlying these putative measures, the rat will remain a questionable subject in which to study motion sickness.
Ferreira, Manuel; Walcott, Brian P; Nahed, Brian V; Sekhar, Laligam N
2011-06-01
Hemifacial spasm (HFS) is caused by arterial or venous compression of cranial nerve VII at its root exit zone. Traditionally, microvascular decompression of the facial nerve has been an effective treatment for posterior inferior and anterior inferior cerebellar artery as well as venous compression. The traditional technique involves Teflon felt or another construct to cushion the offending vessel from the facial nerve, or cautery and division of the offending vein. However, using this technique for severe vertebral artery (VA) compression can be ineffective and fraught with complications. The authors report the use of a new technique of VA pexy to the petrous or clival dura mater in patients with HFS attributed to a severely ectatic and tortuous VA, and detail the results in a series of patients. Six patients with HFS due to VA compression underwent a retrosigmoid craniotomy, combined with a far-lateral approach in some patients. On identification of the site of VA compression, the vessel was mobilized adequately for the decompression. Great care was taken to avoid kinking the perforating vessels arising from the VA. Two 8-0 nylon sutures were passed through to the wall of the VA and then through the clival or petrous dura, and then tied to alleviate compression on cranial nerve VII. Patients were followed for at least 1 year postoperatively (mean 2.7 years, range 1-4 years). All 6 patients had complete resolution of their HFS. Facial function was tested postoperatively, and was stable when compared with the preoperative baseline. Two of the 3 patients with preoperative tinnitus had resolution of this symptom after the procedure. Postoperative imaging demonstrated VA decompression of the facial nerve and no evidence of stroke in all patients. One patient suffered from hearing loss, another developed a postoperative transient unilateral vocal cord paralysis, and a third patient developed a pseudomeningocele that resolved with the placement of a lumbar drain. Hemifacial spasm and other neurovascular syndromes are effectively treated by repositioning the compressing artery. Careful study of the preoperative MR images may identify a select group of patients with HFS due to an ectatic VA. Rather than traditional decompression with only pledget placement, these patients may benefit from a VA pexy to provide an effective, safe, and durable resolution of their symptoms while minimizing surgical complications.
Cortical spreading depression occurs during elective neurosurgical procedures.
Carlson, Andrew P; William Shuttleworth, C; Mead, Brittany; Burlbaw, Brittany; Krasberg, Mark; Yonas, Howard
2017-01-01
OBJECTIVE Cortical spreading depression (CSD) has been observed with relatively high frequency in the period following human brain injury, including traumatic brain injury and ischemic/hemorrhagic stroke. These events are characterized by loss of ionic gradients through massive cellular depolarization, neuronal dysfunction (depression of electrocorticographic [ECoG] activity) and slow spread (2-5 mm/min) across the cortical surface. Previous data obtained in animals have suggested that even in the absence of underlying injury, neurosurgical manipulation can induce CSD and could potentially be a modifiable factor in neurosurgical injury. The authors report their initial experience with direct intraoperative ECoG monitoring for CSD. METHODS The authors prospectively enrolled patients undergoing elective craniotomy for supratentorial lesions in cases in which the surgical procedure was expected to last > 2 hours. These patients were monitored for CSD from the time of dural opening through the time of dural closure, using a standard 1 × 6 platinum electrode coupled with an AC or full-spectrum DC amplifier. The data were processed using standard techniques to evaluate for slow potential changes coupled with suppression of high-frequency ECoG propagating across the electrodes. Data were compared with CSD validated in previous intensive care unit (ICU) studies, to evaluate recording conditions most likely to permit CSD detection, and identify likely events during the course of neurosurgical procedures using standard criteria. RESULTS Eleven patients underwent ECoG monitoring during elective neurosurgical procedures. During the periods of monitoring, 2 definite CSDs were observed to occur in 1 patient and 8 suspicious events were detected in 4 patients. In other patients, either no events were observed or artifact limited interpretation of the data. The DC-coupled amplifier system represented an improvement in stability of data compared with AC-coupled systems. Compared with more widely used postoperative ICU monitoring, there were additional challenges with artifact from saturation during bipolar cautery as well as additional noise peaks detected. CONCLUSIONS CSD can occur during elective neurosurgical procedures even in brain regions distant from the immediate operative site. ECoG monitoring with a DC-coupled full-spectrum amplifier seemed to provide the most stable signal despite significant challenges to the operating room environment. CSD may be responsible for some cases of secondary surgical injury. Though further studies on outcome related to the occurrence of these events is needed, efforts to decrease the occurrence of CSD by modification of anesthetic regimen may represent a novel target for study to increase the safety of neurosurgical procedures.
Hanak, Brian W; Ross, Emily F; Harris, Carolyn A; Browd, Samuel R; Shain, William
2016-08-01
OBJECTIVE Shunt obstruction by cells and/or tissue is the most common cause of shunt failure. Ventricular catheter obstruction alone accounts for more than 50% of shunt failures in pediatric patients. The authors sought to systematically collect explanted ventricular catheters from the Seattle Children's Hospital with a focus on elucidating the cellular mechanisms underlying obstruction. METHODS In the operating room, explanted hardware was placed in 4% paraformaldehyde. Weekly, samples were transferred to buffer solution and stored at 4°C. After consent was obtained for their use, catheters were labeled using cell-specific markers for astrocytes (glial fibrillary acidic protein), microglia (ionized calcium-binding adapter molecule 1), and choroid plexus (transthyretin) in conjunction with a nuclear stain (Hoechst). Catheters were mounted in custom polycarbonate imaging chambers. Three-dimensional, multispectral, spinning-disk confocal microscopy was used to image catheter cerebrospinal fluid-intake holes (10× objective, 499.2-μm-thick z-stack, 2.4-μm step size, Olympus IX81 inverted microscope with motorized stage and charge-coupled device camera). Values are reported as the mean ± standard error of the mean and were compared using a 2-tailed Mann-Whitney U-test. Significance was defined at p < 0.05. RESULTS Thirty-six ventricular catheters have been imaged to date, resulting in the following observations: 1) Astrocytes and microglia are the dominant cell types bound directly to catheter surfaces; 2) cellular binding to catheters is ubiquitous even if no grossly visible tissue is apparent; and 3) immunohistochemical techniques are of limited utility when a catheter has been exposed to Bugbee wire electrocautery. Statistical analysis of 24 catheters was performed, after excluding 7 catheters exposed to Bugbee wire cautery, 3 that were poorly fixed, and 2 that demonstrated pronounced autofluorescence. This analysis revealed that catheters with a microglia-dominant cellular response tended to be implanted for shorter durations (24.7 ± 6.7 days) than those with an astrocyte-dominant response (1183 ± 642 days; p = 0.027). CONCLUSIONS Ventricular catheter occlusion remains a significant source of shunt morbidity in the pediatric population, and given their ability to intimately associate with catheter surfaces, astrocytes and microglia appear to be critical to this pathophysiology. Microglia tend to be the dominant cell type on catheters implanted for less than 2 months, while astrocytes tend to be the most prevalent cell type on catheters implanted for longer time courses and are noted to serve as an interface for the secondary attachment of ependymal cells and choroid plexus.
2012-01-01
Background Bleeding severity, anatomic location, tissue characteristics, and visibility are common challenges encountered while managing intraoperative bleeding, and conventional hemostatic measures (suture, ligature, and cautery) may sometimes be ineffective or impractical. While topical absorbable hemostats (TAH) are useful hemostatic adjuvants, each TAH has associated disadvantages. Methods We evaluated the safety and hemostatic efficacy of a new advanced biologic combination product―fibrin pad―to potentially address some gaps associated with TAHs. Fibrin pad was assessed as adjunctive hemostat in open partial nephrectomy in single-center, open-label, Phase I study (N = 10), and as primary hemostat in multicenter, single-blind, randomized, standard-of-care (SOC)-controlled Phase I/II study (N = 7) in Israel. It was used to control mild-to-moderate bleeding in Phase I and also spurting arterial bleeding in Phase I/II study. Phase I study assessed safety and Phase I/II study, proportion of successes at 10 min following randomization, analyzed by Fisher exact tests at 5% significance level. Results Phase I (N = 10): All patients completed the study. Hemostasis was achieved within 3–4 min (average = 3.1 min) of a single application in all patients. Fibrin pad was found to be safe for human use, with no product-related adverse events reported. Phase I/II (N = 7): Hemostatic success at 10 min (primary endpoint) was achieved in 3/4 patients treated with fibrin pad versus 0/3 patients treated with SOC. No clinically significant change in laboratory or coagulation parameters was recorded, except a case of post-procedural hemorrhage with fibrin pad, which was considered serious and related to the fibrin pad treatment, and required re-operation. Although Data Safety Monitoring Board authorized trial continuation, the sponsor decided against proceeding toward an indication for primary treatment of severe arterial hemorrhage as a replacement for sutures. The study was suspended after 7/30 planned subjects were enrolled. Conclusions The first-in-man trial of fibrin pad demonstrated its safety and efficacy as an adjunctive hemostatic technique for mild-to-moderate bleeding in partial nephrectomy. The study also suggested that the product should not replace sutures or meticulous surgical techniques for the treatment of severe arterial hemorrhage. Trial registration Phase I/II trial, NCT00598130 PMID:23137020
Hötzel, M J; Sneddon, J N
2013-03-01
The majority of dairy calves around the world are dehorned with methods that cause them pain and distress. In some dairy production systems, extensionists may influence dehorning practices used on farm through their advisory and knowledge-transfer role. The aims of this study were to investigate Brazilian extensionists' knowledge, beliefs, and behavior regarding dehorning dairy calves. As little research has addressed this question, a qualitative, theory-building approach was used and the theory of planned behavior was used as a conceptual framework to guide data collection and analysis. In-depth, semi-structured interviews were undertaken with 15 extensionists working in Santa Catarina, Brazil, to examine their role in the adoption and rejection of pain-mitigation strategies at dehorning. The interview transcripts were free coded, identifying 9 major themes within and across interviews. Transcribed interview responses were then coded to constructs in the theory of planned behavior. The themes and constructs that emerged through analysis of the interview responses were combined to develop a conceptual model of extensionists' beliefs, attitudes, and behavior toward recommending protocols for dehorning aimed at minimizing pain. The extensionists interviewed believed that it was necessary to dehorn all dairy replacement heifers. Despite being aware of methods to minimize pain during and after dehorning, all of the interviewees recommended or used the hot cautery method, with no pain control. This method was described as the most effective, cheapest, safest, and fastest method of dehorning. The majority (12) of interviewees rejected the caustic paste method, citing negative past experiences or unfamiliarity with the method and the belief that the method is less practical and riskier for farmers. More than half of the interviewees did not recognize dehorning as painful or expressed the belief that the pain associated with the procedure did not justify the use of pain control. Although a small number of extensionists (4) recognized potential sources of social pressure to change, including the rejection of pain-inflicting practices by some farmers, the Brazilian general public, and animal-protection societies, they did not identify these factors as a reason to change their existing practices. Interviewees expressed the belief that the adoption of practices to minimize pain and stress, such as dehorning very young calves, using caustic paste and pain control, would increase labor and costs associated with dehorning. Extensionists' negative attitudes toward recommending practices that minimize pain during and after dehorning appear to be embedded in the production-focused political and economic agriculture environment and a lack of education, research, and legislation regarding farm animal welfare. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Experimental evaluation of clinical colon anastomotic leakage.
Pommergaard, Hans-Christian
2014-03-01
Colorectal anastomotic leakage remains a frequent and serious complication in gastrointestinal surgery. Patient and procedure related risk factors for anastomotic leakage have been identified. However, the responsible pathophysiological mechanisms are still unknown. Among these, ischemia and insufficient surgical technique have been suggested to play a central role. Animal models are valuable means to evaluate pathophysiological mechanisms and may be used to test preventive measures aiming at reducing the risk of anastomotic leakage, such as external anastomotic coating. The aim of this thesis was to: Clarify the best suited animal to model clinical anastomotic leakage in humans; Create animal models mimicking anastomotic leakage in humans induced by insufficient surgical technique and tissue ischemia; Determine the best suited coating materials to prevent anastomotic leakage. This study is a systematic review using the databases MEDLINE and Rex. MEDLINE was searched up to October 2010 to identify studies on experimental animal models of clinical colon anastomotic leakage. From the Rex database, textbooks on surgical aspects as well as gastrointestinal physiology and anatomy of experimental animals were identified. The results indicated that the mouse and the pig are the best suited animals to evaluate clinical anastomotic leakage. However, the pig model is less validated and more costly to use compared with the mouse. Most frequently, rats are used as models. However, extreme interventions are needed to create clinical leakage in these animals. The knowledge from this study formed the basis for selecting the animal species most suited for the models in the next studies. STUDY 2: In this experimental study, technically insufficient colonic anastomoses were performed in 110 C57BL/6 mice. The number of sutures in the intervention group was reduced to produce a suitable leakage rate. Moreover, the analgesia and suture material were changed in order to optimize the model. In the final experiment, the four-suture anastomoses resulted in a 40% leakage rate in the intervention groups, whereas the eight-suture control anastomoses had a 0% leakage rate. Furthermore, the use of absorbable suture together with voluntarily ingested Temgesic in chocolate spread as analgesic regimen were feasible. This model may be used to test the leakage reducing potential of coating materials. STUDY 3: This experimental study used 53 C57BL/6 mice, in which sufficient eight-suture anastomoses were created. By using bipolar electro-cautery, blood supply was reduced in a stepwise manner to create anastomotic leakage as a result of ischemia. The study showed that reduced blood supply led to large bowel obstruction instead of clinical leakage. However, anastomotic breaking strength was reduced in the ischemic anastomoses. STUDY 4: In this systematic review MEDLINE, Embase and Cinahl were searched up to September 2011 to identify studies evaluating external coating of colonic anastomoses. Most studies were experimental, in which designs were not comparable and many results were contradictory. In a clinical study, a non-significant benefit of fibrin sealant was found. Based on the available clinical and experimental data it was concluded that the fibrin-based sealants, such as Tisseel and Tachosil, and polyethylene glycols may be beneficial. However, further experimental and clinical studies are needed before routine clinical use can be recommended. The studies in this thesis may be valuable for the experimental research field of clinical anastomotic leakage. The model of technical insufficiency has been improved and is now thoroughly validated. If used by researchers worldwide, comparison of results is possible. Pure ischemia/anoxia may be too simple an approach to create a clinical leakage model. Thus, future models could focus on multiple risk factors. Conclusively, large-scale clinical multicenter studies are needed to definitively evaluate whether coating of colorectal anastomoses may reduce the leakage rate.
Byeon, Hyung Kwon; Ban, Myung Jin; Lee, Jeon Mi; Ha, Jong Gyun; Kim, Eun Sung; Koh, Yoon Woo; Choi, Eun Chang
2012-12-01
Carcinomas arising in the thyroglossal duct cysts are rare, accounting only for about 0.7-1.5 % of all thyroglossal duct cysts. Synchronous occurrence of thyroglossal duct carcinoma and thyroid carcinoma is reported to be even rarer. Traditionally, surgical treatments of such coexisting thyroglossal duct cyst carcinoma (TGDCa) and papillary thyroid carcinoma (PTC) were typically performed through a single transverse or double incisions on the overlying skin. A longer, extended cervical incision might be required if neck dissection is necessary. Though this method provides the operator with the optimal surgical view, the detrimental cosmetic effect on the patient of possessing a scar cannot be avoided, despite the effort of the surgeon to camouflage the scar by placing the incision in natural skin creases. Recently, the authors have previously reported the feasibility of robot-assisted neck dissections via a transaxillary and retroauricular ("TARA") approach or modified face-lift approach in early head and neck cancers. On the basis of the forementioned surgical technique, we demonstrate our novel technique for robot-assisted Sistrunk's operation via retroauricular approach as well as robot-assisted neck dissection with total thyroidectomy via transaxillary approach. This is a case presentation of a 22-year-old woman with synchronous TGDCa and PTC with minimal lymph node metastasis who underwent resection of TGDCa and total thyroidectomy with left neck level III and IV lymph node dissection as well as central compartment lymph node dissection (CCND) via TARA approach with a robotic surgery system after approval from the institutional review board at Severance Hospital, Yonsei University College of Medicine. The incision was just like the TARA approach in head and neck cancer, which has been reported by our institute. The operation was proceeded as follows. First, excision of the TGDCa through the retroauricular incision was done followed by total thyroidectomy with CCND via transaxillary approach. Finally, neck dissection of left level III, IV was conducted via transaxillary approach. The da Vinci surgical system (Intuitive Surgical, Sunnyvale, CA) was introduced via retroauricular or transaxillary port. A 30° dual-channel endoscope was used, and the two instrument arms were equipped with 5 mm Maryland forceps and a 5 mm spatula monopolar cautery for TGDCa excision via retroauricular approach. When conducting total thyroidectomy and neck dissection via transaxillary approach, three instrument arms were utilized, each equipped with 5 mm Maryland forceps, ProGrasp forceps and a 5 mm spatula monopolar cautery or Harmonic curved shears. The rest of the surgery was completed with the robotic system (see Video). The operative procedure was successfully completed utilizing the robotic surgical system with no conversion to open surgery. The operation time for TGDCa excision was 97 min, including the time for skin flap elevation (15 min), setting up the robotic system (5 min), and console time using the robotic system (77 min). Also, the total operation time for the consecutive total thyroidectomy with CCND and level III, IV dissection was 142 min including the time for skin flap elevation (27 min), setting up the robotic system (3 min), and console time using the robotic system (112 min). There were no intraoperative complications. The retroauricular approach for the removal of the TGDCa allowed for an excellent magnified surgical view revealing important structures of the local anatomy. It also created sufficient space for the cutting of the relevant portion of the hyoid bone. Handling of the robotic instruments through the incision was technically feasible and safe without any mutual collisions throughout the operation. The patient's postoperative parathyroid hormone (PTH) level was within normal range and functions of her both vocal cords were intact. The histopathologic results of the specimens revealed thyroglossal duct cyst with internal papillary carcinoma measuring 1.1 cm with infiltrative tumor margins and papillary microcarcinoma measuring 0.9 cm within the left thyroid lobe with extrathyroidal soft tissue extension. There was no evidence of tumor in the right lobe and the pyramidal lobe of the thyroid gland. As for the lymph nodes resected, 7 out of 9 paratracheal nodes and 2 out of 7 left level III, IV nodes revealed metastatic carcinomas. The patient was discharged on the 8th day after the operation with no complications. The patient was extremely satisfied with the cosmetic results. The patient has received high-dose radioiodine ablation (RAI) therapy and is currently doing well with no evidence of recurrence. Although there is still a great deal of controversy regarding the treatment of TGDCa, there is little debate that for the cases of synchronous TGDCa and PTC, total thyroidectomy in addition to the Sistrunk procedure must be performed. As for the patient in our case where left level IV lymph node metastasis was detected under preoperative ultrasonography (USG), if the usual method of surgical procedure was to be selected, double incisions or a single extended transverse incision must be adopted for the Sistrunk's operation and total thyroidectomy with lateral neck dissection. The conventional method to remove neck masses was to do so by placing an incision on the overlying skin. This 'open' approach to viewing the lesion has an advantage of providing the operator with the best surgical view, but the recognizable surgical scar that results from the surgery can be displeasing for patients. Therefore the surgeon can try to make a small incision and camouflage the scar by placing the incision in natural skin creases, yet the cosmetic results can still be displeasing for the patient due to its visibility and permanence. This can be an even greater problem if the patient is young and an active member of his/her society and if the lesion is benign or low-grade malignancy which can be simply dissected and excised. Therefore it is the surgeon's best interest to perform an operation successfully with a 'least obvious' or 'hidden' scar whenever possible. Accordingly, we have adopted a novel approach, the transaxillary and retroauricular approach, in view of our increasing surgical experience with various indications such as submandibular gland (SMG) resections and neck dissections in head and neck cancer or thyroid papillary carcinoma. Some investigators have demonstrated that robot-assisted neck dissections performed on patients with thyroid cancer and lateral neck node metastasis are feasible and safe. We conducted total thyroidectomy with bilateral CCND and level III and IV dissection using the same approach. Although the technical feasibility and safety of neck dissection or SMG resection via retroauricular approach has already been reported previously at our institute, Sistrunk's operation via retroauricular approach will be challenging. In spite of that, we were able to demonstrate successfully Sistrunk's operation including the hyoid bone resection through the retroauricular approach. There are however, certain areas of potential difficulties which must be considered with caution during the operation procedure. First, when removing the TGDCa through the retroauricular port, identification of the ipsilateral hyoid bone is primarily important and it is also crucial that dissection along the capsule must be done carefully so as not to rupture the tumor. It is essential that sufficient working space must be created for the comfortable movement of the robotic arms through the retroauricular port and in order to do so, sufficient skin flap elevation in both superior and inferior directions must be performed. It is necessary to elevate the superior skin flap up to the level of the inferior border of the mandible but during this process, the platysma muscle must be identified and meticulous dissection along the subplatysmal plane must be carried out so as not to damage the marginal mandibular branch of the facial nerve. Another area of potential pitfalls concerns the total thyroidectomy with neck dissection through the transaxillary port. Sufficient amount of working space must be secured in order to perform comfortably the contralateral thyroidectomy and neck dissection and in order to do so, skin flap elevation must be done at least 2 cm further based on the ipsilateral omohyoid muscle and the contralateral thyroid gland must be adequately exposed. Using the robotic surgical system in removing the thyroglossal duct cyst, the free movement of wristed instrumentation through the retroauricular incision allowed for efficient dissection and easy handling of the tissue. In this particular case we could not identify the tract beyond the hyoid and up to the foramen cecum, but we anticipate that there would be no technical problems of dissection and excision had it been so. To our knowledge, Sistrunk's operation and total thyroidectomy with lateral neck dissection via TARA approach utilizing the robotic surgical system has never been attempted before. It has some advantages over the conventional surgery in terms of cosmesis. However, careful consideration in selecting appropriate cases is required and prospective trials should be conducted to recognize long-term outcomes and to overcome potential limitations.